WorldWideScience

Sample records for protocol layer standard

  1. Telemetry Standards, IRIG Standard 106-17, Chapter 22, Network Based Protocol Suite

    Science.gov (United States)

    2017-07-01

    requirements. 22.2 Network Access Layer 22.2.1 Physical Layer Connectors and cable media should meet the electrical or optical properties required by the...Telemetry Standards, IRIG Standard 106-17 Chapter 22, July 2017 i CHAPTER 22 Network -Based Protocol Suite Acronyms...iii Chapter 22. Network -Based Protocol Suite

  2. Cross-Layer Protocol as a Better Option in Wireless Mesh Network with Respect to Layered-Protocol

    OpenAIRE

    Ahmed Abdulwahab Al-Ahdal; Dr. V. P. Pawar; G. N. Shinde

    2014-01-01

    The Optimal way to improve Wireless Mesh Networks (WMNs) performance is to use a better network protocol, but whether layered-protocol design or cross-layer design is a better option to optimize protocol performance in WMNs is still an on-going research topic. In this paper, we focus on cross-layer protocol as a better option with respect to layered-protocol. The layered protocol architecture (OSI) model divides networking tasks into layers and defines a pocket of services for each layer to b...

  3. Application Protocol, Initial Graphics Exchange Specification (IGES), Layered Electrical Product

    Energy Technology Data Exchange (ETDEWEB)

    O`Connell, L.J. [ed.

    1994-12-01

    An application protocol is an information systems engineering view of a specific product The view represents an agreement on the generic activities needed to design and fabricate the product the agreement on the information needed to support those activities, and the specific constructs of a product data standard for use in transferring some or all of the information required. This application protocol describes the data for electrical and electronic products in terms of a product description standard called the Initial Graphics Exchange Specification (IGES). More specifically, the Layered Electrical Product IGES Application Protocol (AP) specifies the mechanisms for defining and exchanging computer-models and their associated data for those products which have been designed in two dimensional geometry so as to be produced as a series of layers in IGES format The AP defines the appropriateness of the data items for describing the geometry of the various parts of a product (shape and location), the connectivity, and the processing and material characteristics. Excluded is the behavioral requirements which the product was intended to satisfy, except as those requirements have been recorded as design rules or product testing requirements.

  4. The case for a network protocol isolation layer

    KAUST Repository

    Il Choi, Jung

    2009-01-01

    Network protocols are typically designed and tested individually. In practice, however, applications use multiple protocols concurrently. This discrepancy can lead to failures from unanticipated interactions between protocols. In this paper, we argue that sensor network communication stacks should have an isolation layer, whose purpose is to make each protocol\\'s perception of the wireless channel independent of what other protocols are running. We identify two key mechanisms the isolation layer must provide: shared collision avoidance and fair channel allocation. We present an example design of an isolation layer that builds on the existing algorithms of grant-to-send and fair queueing. However, the complexities of wireless make these mechanisms insufficient by themselves. We therefore propose two new mechanisms that address these limitations: channel decay and fair cancellation. Incorporating these new mechanisms reduces the increase in end-to-end delivery cost associated with concurrently operating two protocols by more than 60%. The isolation layer improves median protocol fairness from 0.52 to 0.96 in Jain\\'s fairness index. Together, these results show that using an isolation layer makes protocols more efficient and robust. Copyright 2009 ACM.

  5. The case for a network protocol isolation layer

    KAUST Repository

    Il Choi, Jung; Kazandjieva, Maria A.; Jain, Mayank; Levis, Philip

    2009-01-01

    Network protocols are typically designed and tested individually. In practice, however, applications use multiple protocols concurrently. This discrepancy can lead to failures from unanticipated interactions between protocols. In this paper, we argue that sensor network communication stacks should have an isolation layer, whose purpose is to make each protocol's perception of the wireless channel independent of what other protocols are running. We identify two key mechanisms the isolation layer must provide: shared collision avoidance and fair channel allocation. We present an example design of an isolation layer that builds on the existing algorithms of grant-to-send and fair queueing. However, the complexities of wireless make these mechanisms insufficient by themselves. We therefore propose two new mechanisms that address these limitations: channel decay and fair cancellation. Incorporating these new mechanisms reduces the increase in end-to-end delivery cost associated with concurrently operating two protocols by more than 60%. The isolation layer improves median protocol fairness from 0.52 to 0.96 in Jain's fairness index. Together, these results show that using an isolation layer makes protocols more efficient and robust. Copyright 2009 ACM.

  6. A Performance Evaluation of NACK-Oriented Protocols as the Foundation of Reliable Delay- Tolerant Networking Convergence Layers

    Science.gov (United States)

    Iannicca, Dennis; Hylton, Alan; Ishac, Joseph

    2012-01-01

    Delay-Tolerant Networking (DTN) is an active area of research in the space communications community. DTN uses a standard layered approach with the Bundle Protocol operating on top of transport layer protocols known as convergence layers that actually transmit the data between nodes. Several different common transport layer protocols have been implemented as convergence layers in DTN implementations including User Datagram Protocol (UDP), Transmission Control Protocol (TCP), and Licklider Transmission Protocol (LTP). The purpose of this paper is to evaluate several stand-alone implementations of negative-acknowledgment based transport layer protocols to determine how they perform in a variety of different link conditions. The transport protocols chosen for this evaluation include Consultative Committee for Space Data Systems (CCSDS) File Delivery Protocol (CFDP), Licklider Transmission Protocol (LTP), NACK-Oriented Reliable Multicast (NORM), and Saratoga. The test parameters that the protocols were subjected to are characteristic of common communications links ranging from terrestrial to cis-lunar and apply different levels of delay, line rate, and error.

  7. The development of standard operating protocols for paediatric radiology

    International Nuclear Information System (INIS)

    Hardwick, J.; Mencik, C.; McLaren, C.; Young, C.; Scadden, S.; Mashford, P.; McHugh, K.; Beckett, M.; Calvert, M.; Marsden, P.J.

    2001-01-01

    This paper describes how the requirement for operating protocols for standard radiological practice was expanded to provide a comprehensive aide to the operator conducting a medical exposure. The protocols adopted now include justification criteria, patient preparation, radiographic technique, standard exposure charts, diagnostic reference levels and image quality criteria. In total, the protocols have been welcomed as a tool for ensuring that medical exposures are properly optimised. (author)

  8. SPIRIT 2013 Statement: defining standard protocol items for clinical trials.

    Science.gov (United States)

    Chan, An-Wen; Tetzlaff, Jennifer M; Altman, Douglas G; Laupacis, Andreas; Gøtzsche, Peter C; Krle A-Jerić, Karmela; Hrobjartsson, Asbjørn; Mann, Howard; Dickersin, Kay; Berlin, Jesse A; Dore, Caroline J; Parulekar, Wendy R; Summerskill, William S M; Groves, Trish; Schulz, Kenneth F; Sox, Harold C; Rockhold, Frank W; Rennie, Drummond; Moher, David

    2015-12-01

    The protocol of a clinical trial serves as the foundation for study planning, conduct, reporting, and appraisal. However, trial protocols and existing protocol guidelines vary greatly in content and quality. This article describes the systematic development and scope of SPIRIT (Standard Protocol Items: Recommendations for Interventional Trials) 2013, a guideline for the minimum content of a clinical trial protocol. The 33-item SPIRIT checklist applies to protocols for all clinical trials and focuses on content rather than format. The checklist recommends a full description of what is planned; it does not prescribe how to design or conduct a trial. By providing guidance for key content, the SPIRIT recommendations aim to facilitate the drafting of high-quality protocols. Adherence to SPIRIT would also enhance the transparency and completeness of trial protocols for the benefit of investigators, trial participants, patients, sponsors, funders, research ethics committees or institutional review boards, peer reviewers, journals, trial registries, policymakers, regulators, and other key stakeholders.

  9. Comparison of test protocols for standard room/corner tests

    Science.gov (United States)

    R. H. White; M. A. Dietenberger; H. Tran; O. Grexa; L. Richardson; K. Sumathipala; M. Janssens

    1998-01-01

    As part of international efforts to evaluate alternative reaction-to-fire tests, several series of room/comer tests have been conducted. This paper reviews the overall results of related projects in which different test protocols for standard room/corner tests were used. Differences in the test protocols involved two options for the ignition burner scenario and whether...

  10. Protocol Interoperability Between DDN and ISO (Defense Data Network and International Organization for Standardization) Protocols

    Science.gov (United States)

    1988-08-01

    services and protocols above the transport layer are usually implemented as user- callable utilities on the host computers, it is desirable to offer them...Networks, Prentice-hall, New Jersey, 1987 [ BOND 87] Bond , John, "Parallel-Processing Concepts Finally Come together in Real Systems", Computer Design

  11. A Novel Process Audit for Standardized Perioperative Handoff Protocols.

    Science.gov (United States)

    Pallekonda, Vinay; Scholl, Adam T; McKelvey, George M; Amhaz, Hassan; Essa, Deanna; Narreddy, Spurthy; Tan, Jens; Templonuevo, Mark; Ramirez, Sasha; Petrovic, Michelle A

    2017-11-01

    A perioperative handoff protocol provides a standardized delivery of communication during a handoff that occurs from the operating room to the postanestheisa care unit or ICU. The protocol's success is dependent, in part, on its continued proper use over time. A novel process audit was developed to help ensure that a perioperative handoff protocol is used accurately and appropriately over time. The Audit Observation Form is used for the Audit Phase of the process audit, while the Audit Averages Form is used for the Data Analysis Phase. Employing minimal resources and using quantitative methods, the process audit provides the necessary means to evaluate the proper execution of any perioperative handoff protocol. Copyright © 2017 The Joint Commission. Published by Elsevier Inc. All rights reserved.

  12. Standardized CT protocols and nomenclature: better, but not yet there

    Energy Technology Data Exchange (ETDEWEB)

    Singh, Sarabjeet; Kalra, Mannudeep K. [Harvard Medical School, Department of Radiology, Massachusetts General Hospital, Boston, MA (United States)

    2014-10-15

    Radiation dose associated with CT is an important safety concern in patient care, especially in children. Technical advancements in multidetector-row CT scanner technology offer several advantages for clinical applications; these advancements have considerably increased CT utilization and enhanced the complexity of CT scanning protocols. Furthermore there are several scan manufacturers spearheading these technical advancements, leading to different commercial names causing confusion among the users, especially at imaging sites with scanners from different vendors. Several scientific studies and the National Council on Radiation Protection and Measurements (NCRP) have shown variation in CT radiation doses for same body region and similar scanning protocols. Therefore there is a need for standardization of scanning protocols and nomenclature of scan parameters. The following material reviews the status and challenges in standardization of CT scanning and nomenclature. (orig.)

  13. The Virtual Insect Brain protocol: creating and comparing standardized neuroanatomy

    Directory of Open Access Journals (Sweden)

    Schindelin Johannes E

    2006-12-01

    Full Text Available Abstract Background In the fly Drosophila melanogaster, new genetic, physiological, molecular and behavioral techniques for the functional analysis of the brain are rapidly accumulating. These diverse investigations on the function of the insect brain use gene expression patterns that can be visualized and provide the means for manipulating groups of neurons as a common ground. To take advantage of these patterns one needs to know their typical anatomy. Results This paper describes the Virtual Insect Brain (VIB protocol, a script suite for the quantitative assessment, comparison, and presentation of neuroanatomical data. It is based on the 3D-reconstruction and visualization software Amira, version 3.x (Mercury Inc. 1. Besides its backbone, a standardization procedure which aligns individual 3D images (series of virtual sections obtained by confocal microscopy to a common coordinate system and computes average intensities for each voxel (volume pixel the VIB protocol provides an elaborate data management system for data administration. The VIB protocol facilitates direct comparison of gene expression patterns and describes their interindividual variability. It provides volumetry of brain regions and helps to characterize the phenotypes of brain structure mutants. Using the VIB protocol does not require any programming skills since all operations are carried out at an intuitively usable graphical user interface. Although the VIB protocol has been developed for the standardization of Drosophila neuroanatomy, the program structure can be used for the standardization of other 3D structures as well. Conclusion Standardizing brains and gene expression patterns is a new approach to biological shape and its variability. The VIB protocol provides a first set of tools supporting this endeavor in Drosophila. The script suite is freely available at http://www.neurofly.de2

  14. The Virtual Insect Brain protocol: creating and comparing standardized neuroanatomy

    Science.gov (United States)

    Jenett, Arnim; Schindelin, Johannes E; Heisenberg, Martin

    2006-01-01

    Background In the fly Drosophila melanogaster, new genetic, physiological, molecular and behavioral techniques for the functional analysis of the brain are rapidly accumulating. These diverse investigations on the function of the insect brain use gene expression patterns that can be visualized and provide the means for manipulating groups of neurons as a common ground. To take advantage of these patterns one needs to know their typical anatomy. Results This paper describes the Virtual Insect Brain (VIB) protocol, a script suite for the quantitative assessment, comparison, and presentation of neuroanatomical data. It is based on the 3D-reconstruction and visualization software Amira, version 3.x (Mercury Inc.) [1]. Besides its backbone, a standardization procedure which aligns individual 3D images (series of virtual sections obtained by confocal microscopy) to a common coordinate system and computes average intensities for each voxel (volume pixel) the VIB protocol provides an elaborate data management system for data administration. The VIB protocol facilitates direct comparison of gene expression patterns and describes their interindividual variability. It provides volumetry of brain regions and helps to characterize the phenotypes of brain structure mutants. Using the VIB protocol does not require any programming skills since all operations are carried out at an intuitively usable graphical user interface. Although the VIB protocol has been developed for the standardization of Drosophila neuroanatomy, the program structure can be used for the standardization of other 3D structures as well. Conclusion Standardizing brains and gene expression patterns is a new approach to biological shape and its variability. The VIB protocol provides a first set of tools supporting this endeavor in Drosophila. The script suite is freely available at [2] PMID:17196102

  15. Biocoder: A programming language for standardizing and automating biology protocols.

    Science.gov (United States)

    Ananthanarayanan, Vaishnavi; Thies, William

    2010-11-08

    Published descriptions of biology protocols are often ambiguous and incomplete, making them difficult to replicate in other laboratories. However, there is increasing benefit to formalizing the descriptions of protocols, as laboratory automation systems (such as microfluidic chips) are becoming increasingly capable of executing them. Our goal in this paper is to improve both the reproducibility and automation of biology experiments by using a programming language to express the precise series of steps taken. We have developed BioCoder, a C++ library that enables biologists to express the exact steps needed to execute a protocol. In addition to being suitable for automation, BioCoder converts the code into a readable, English-language description for use by biologists. We have implemented over 65 protocols in BioCoder; the most complex of these was successfully executed by a biologist in the laboratory using BioCoder as the only reference. We argue that BioCoder exposes and resolves ambiguities in existing protocols, and could provide the software foundations for future automation platforms. BioCoder is freely available for download at http://research.microsoft.com/en-us/um/india/projects/biocoder/. BioCoder represents the first practical programming system for standardizing and automating biology protocols. Our vision is to change the way that experimental methods are communicated: rather than publishing a written account of the protocols used, researchers will simply publish the code. Our experience suggests that this practice is tractable and offers many benefits. We invite other researchers to leverage BioCoder to improve the precision and completeness of their protocols, and also to adapt and extend BioCoder to new domains.

  16. Layered Electrical Product Application Protocol (AP). Draft: Initial Graphics Exchange Specification (IGES)

    Energy Technology Data Exchange (ETDEWEB)

    1994-09-01

    An application protocol is an information systems engineering view of a specific product. The view represents an agreement on the generic activities needed to design and fabricate the product, the agreement on the information needed to support those activities, and the specific constructs of a product data standard for use in transfering some or all of the information required. This applications protocol describes the data for electrical and electronic products in terms of a product description standard called the Initial Graphics Exchange Specification (IGES). More specifically, the Layered Electrical Product IGES Application Protocol (AP) specifies the mechanisms for defining and exchanging computer-models and their associated data for those products which have been designed in two dimensional geometry so as to be produced as a series of layers in IGES format. The AP defines the appropriateness of the data items for describing the geometry of the various parts of a product (shape and location), the connectivity, and the processing and material characteristics. Excluded is the behavioral requirements which the product was intended to satisfy, except as those requirements have been recorded as design rules or product testing requirements.

  17. Protocol Standards for Reporting Video Data in Academic Journals.

    Science.gov (United States)

    Rowland, Pamela A; Ignacio, Romeo C; de Moya, Marc A

    2016-04-01

    Editors of biomedical journals have estimated that a majority (40%-90%) of studies published in scientific journals cannot be replicated, even though an inherent principle of publication is that others should be able to replicate and build on published claims. Each journal sets its own protocols for establishing "quality" in articles, yet over the past 50 years, few journals in any field--especially medical education--have specified protocols for reporting the use of video data in research. The authors found that technical and industry-driven aspects of video recording, as well as a lack of standardization and reporting requirements by research journals, have led to major limitations in the ability to assess or reproduce video data used in research. Specific variables in the videotaping process (e.g., camera angle), which can be changed or be modified, affect the quality of recorded data, leading to major reporting errors and, in turn, unreliable conclusions. As more data are now in the form of digital videos, the historical lack of reporting standards makes it increasingly difficult to accurately replicate medical educational studies. Reproducibility is especially important as the medical education community considers setting national high-stakes standards in medicine and surgery based on video data. The authors of this Perspective provide basic protocol standards for investigators and journals using video data in research publications so as to allow for reproducibility.

  18. Industrial wireless sensor networks applications, protocols, and standards

    CERN Document Server

    Güngör, V Çagri

    2013-01-01

    The collaborative nature of industrial wireless sensor networks (IWSNs) brings several advantages over traditional wired industrial monitoring and control systems, including self-organization, rapid deployment, flexibility, and inherent intelligent processing. In this regard, IWSNs play a vital role in creating more reliable, efficient, and productive industrial systems, thus improving companies' competitiveness in the marketplace. Industrial Wireless Sensor Networks: Applications, Protocols, and Standards examines the current state of the art in industrial wireless sensor networks and outline

  19. Cross Layer PHY-MAC Protocol for Wireless Static and Mobile Ad Hoc Networks

    Directory of Open Access Journals (Sweden)

    Chris Blondia

    2008-11-01

    Full Text Available Multihop mobile wireless networks have drawn a lot of attention in recent years thanks to their wide applicability in civil and military environments. Since the existing IEEE 802.11 distributed coordination function (DCF standard does not provide satisfactory access to the wireless medium in multihop mobile networks, we have designed a cross-layer protocol, (CroSs-layer noise aware power driven MAC (SNAPdMac, which consists of two parts. The protocol first concentrates on the flexible adjustment of the upper and lower bounds of the contention window (CW to lower the number of collisions. In addition, it uses a power control scheme, triggered by the medium access control (MAC layer, to limit the waste of energy and also to decrease the number of collisions. Thanks to a noticeable energy conservation and decrease of the number of collisions, it prolongs significantly the lifetime of the network and delays the death of the first node while increasing both the throughput performance and the sending bit rate/throughput fairness among contending flows.

  20. From Expert Protocols to Standardized Management of Infectious Diseases.

    Science.gov (United States)

    Lagier, Jean-Christophe; Aubry, Camille; Delord, Marion; Michelet, Pierre; Tissot-Dupont, Hervé; Million, Matthieu; Brouqui, Philippe; Raoult, Didier; Parola, Philippe

    2017-08-15

    We report here 4 examples of management of infectious diseases (IDs) at the University Hospital Institute Méditerranée Infection in Marseille, France, to illustrate the value of expert protocols feeding standardized management of IDs. First, we describe our experience on Q fever and Tropheryma whipplei infection management based on in vitro data and clinical outcome. Second, we describe our management-based approach for the treatment of infective endocarditis, leading to a strong reduction of mortality rate. Third, we report our use of fecal microbiota transplantation to face severe Clostridium difficile infections and to perform decolonization of patients colonized by emerging highly resistant bacteria. Finally, we present the standardized management of the main acute infections in patients admitted in the emergency department, promoting antibiotics by oral route, checking compliance with the protocol, and avoiding the unnecessary use of intravenous and urinary tract catheters. Overall, the standardization of the management is the keystone to reduce both mortality and morbidity related to IDs. © The Author 2017. Published by Oxford University Press for the Infectious Diseases Society of America. All rights reserved. For permissions, e-mail: journals.permissions@oup.com.

  1. A Protocol Layer Trust-Based Intrusion Detection Scheme for Wireless Sensor Networks

    Directory of Open Access Journals (Sweden)

    Jian Wang

    2017-05-01

    Full Text Available This article proposes a protocol layer trust-based intrusion detection scheme for wireless sensor networks. Unlike existing work, the trust value of a sensor node is evaluated according to the deviations of key parameters at each protocol layer considering the attacks initiated at different protocol layers will inevitably have impacts on the parameters of the corresponding protocol layers. For simplicity, the paper mainly considers three aspects of trustworthiness, namely physical layer trust, media access control layer trust and network layer trust. The per-layer trust metrics are then combined to determine the overall trust metric of a sensor node. The performance of the proposed intrusion detection mechanism is then analyzed using the t-distribution to derive analytical results of false positive and false negative probabilities. Numerical analytical results, validated by simulation results, are presented in different attack scenarios. It is shown that the proposed protocol layer trust-based intrusion detection scheme outperforms a state-of-the-art scheme in terms of detection probability and false probability, demonstrating its usefulness for detecting cross-layer attacks.

  2. Standards-Based Wireless Sensor Networking Protocols for Spaceflight Applications

    Science.gov (United States)

    Wagner, Raymond S.

    2010-01-01

    Wireless sensor networks (WSNs) have the capacity to revolutionize data gathering in both spaceflight and terrestrial applications. WSNs provide a huge advantage over traditional, wired instrumentation since they do not require wiring trunks to connect sensors to a central hub. This allows for easy sensor installation in hard to reach locations, easy expansion of the number of sensors or sensing modalities, and reduction in both system cost and weight. While this technology offers unprecedented flexibility and adaptability, implementing it in practice is not without its difficulties. Recent advances in standards-based WSN protocols for industrial control applications have come a long way to solving many of the challenges facing practical WSN deployments. In this paper, we will overview two of the more promising candidates - WirelessHART from the HART Communication Foundation and ISA100.11a from the International Society of Automation - and present the architecture for a new standards-based sensor node for networking and applications research.

  3. Pelvic Muscle Rehabilitation: A Standardized Protocol for Pelvic Floor Dysfunction

    Directory of Open Access Journals (Sweden)

    Rodrigo Pedraza

    2014-01-01

    Full Text Available Introduction. Pelvic floor dysfunction syndromes present with voiding, sexual, and anorectal disturbances, which may be associated with one another, resulting in complex presentation. Thus, an integrated diagnosis and management approach may be required. Pelvic muscle rehabilitation (PMR is a noninvasive modality involving cognitive reeducation, modification, and retraining of the pelvic floor and associated musculature. We describe our standardized PMR protocol for the management of pelvic floor dysfunction syndromes. Pelvic Muscle Rehabilitation Program. The diagnostic assessment includes electromyography and manometry analyzed in 4 phases: (1 initial baseline phase; (2 rapid contraction phase; (3 tonic contraction and endurance phase; and (4 late baseline phase. This evaluation is performed at the onset of every session. PMR management consists of 6 possible therapeutic modalities, employed depending on the diagnostic evaluation: (1 down-training; (2 accessory muscle isolation; (3 discrimination training; (4 muscle strengthening; (5 endurance training; and (6 electrical stimulation. Eight to ten sessions are performed at one-week intervals with integration of home exercises and lifestyle modifications. Conclusions. The PMR protocol offers a standardized approach to diagnose and manage pelvic floor dysfunction syndromes with potential advantages over traditional biofeedback, involving additional interventions and a continuous pelvic floor assessment with management modifications over the clinical course.

  4. Standardized protocol for artery-only fingertip replantation.

    Science.gov (United States)

    Buntic, Rudolf F; Brooks, Darrell

    2010-09-01

    Artery-only fingertip replantation can be reliable if low-resistance flow through the replant is maintained until venous outflow is restored naturally. Injuring the tip of the replant to promote ongoing bleeding augmented with anticoagulation usually accomplishes this; however, such management results in prolonged hospitalization. In this study, we analyzed the outcomes of artery-only fingertip replantation using a standardized postoperative protocol consisting of dextran-40, heparin, and leech therapy. Between 2001 and 2008, we performed 19 artery-only fingertip replants for 17 patients. All patients had the replanted nail plate removed and received intravenous dextran-40, heparin, and aspirin to promote fingertip bleeding and vascular outflow. Anticoagulation was titrated to promote a controlled bleed until physiologic venous outflow was restored by neovascularization. We used medicinal leeches and mechanical heparin scrubbing for acute decongestion. By postoperative day 6, bleeding was no longer promoted. We initiated fluorescent dye perfusion studies to assess circulatory competence and direct further anticoagulant intervention if necessary. The absence of bleeding associated with an initial rise followed by an appropriate fall in fluorescent dye concentration would trigger a weaning of anticoagulation. All of the 19 replants survived. The average length of hospital stay was 9 days (range, 7-17 d). Eleven patients received blood transfusions. The average transfusion was 1.8 units (range, 0-9 units). All patients were happy with the decision to replant, and the cosmetic result. A protocol that promotes temporary, controlled bleeding from the fingertip is protective of artery-only replants distal to the distal interphalangeal joint until physiologic venous outflow is restored. The protocol described is both safe and reliable. The patient should be informed that such replant attempts may result in the need for transfusions and extended hospital stays, factors that

  5. New secure communication-layer standard for medical image management (ISCL)

    Science.gov (United States)

    Kita, Kouichi; Nohara, Takashi; Hosoba, Minoru; Yachida, Masuyoshi; Yamaguchi, Masahiro; Ohyama, Nagaaki

    1999-07-01

    This paper introduces a summary of the standard draft of ISCL 1.00 which will be published by MEDIS-DC officially. ISCL is abbreviation of Integrated Secure Communication Layer Protocols for Secure Medical Image Management Systems. ISCL is a security layer which manages security function between presentation layer and TCP/IP layer. ISCL mechanism depends on basic function of a smart IC card and symmetric secret key mechanism. A symmetry key for each session is made by internal authentication function of a smart IC card with a random number. ISCL has three functions which assure authentication, confidently and integrity. Entity authentication process is done through 3 path 4 way method using functions of internal authentication and external authentication of a smart iC card. Confidentially algorithm and MAC algorithm for integrity are able to be selected. ISCL protocols are communicating through Message Block which consists of Message Header and Message Data. ISCL protocols are evaluating by applying to regional collaboration system for image diagnosis, and On-line Secure Electronic Storage system for medical images. These projects are supported by Medical Information System Development Center. These project shows ISCL is useful to keep security.

  6. The need for LWR metrology standardization: the imec roughness protocol

    Science.gov (United States)

    Lorusso, Gian Francesco; Sutani, Takumichi; Rutigliani, Vito; van Roey, Frieda; Moussa, Alain; Charley, Anne-Laure; Mack, Chris; Naulleau, Patrick; Constantoudis, Vassilios; Ikota, Masami; Ishimoto, Toru; Koshihara, Shunsuke

    2018-03-01

    As semiconductor technology keeps moving forward, undeterred by the many challenges ahead, one specific deliverable is capturing the attention of many experts in the field: Line Width Roughness (LWR) specifications are expected to be less than 2nm in the near term, and to drop below 1nm in just a few years. This is a daunting challenge and engineers throughout the industry are trying to meet these targets using every means at their disposal. However, although current efforts are surely admirable, we believe they are not enough. The fact is that a specification has a meaning only if there is an agreed methodology to verify if the criterion is met or not. Such a standardization is critical in any field of science and technology and the question that we need to ask ourselves today is whether we have a standardized LWR metrology or not. In other words, if a single reference sample were provided, would everyone measuring it get reasonably comparable results? We came to realize that this is not the case and that the observed spread in the results throughout the industry is quite large. In our opinion, this makes the comparison of LWR data among institutions, or to a specification, very difficult. In this paper, we report the spread of measured LWR data across the semiconductor industry. We investigate the impact of image acquisition, measurement algorithm, and frequency analysis parameters on LWR metrology. We review critically some of the International Technology Roadmap for Semiconductors (ITRS) metrology guidelines (such as measurement box length larger than 2μm and the need to correct for SEM noise). We compare the SEM roughness results to AFM measurements. Finally, we propose a standardized LWR measurement protocol - the imec Roughness Protocol (iRP) - intended to ensure that every time LWR measurements are compared (from various sources or to specifications), the comparison is sensible and sound. We deeply believe that the industry is at a point where it is

  7. Feature-Driven Domain Analysis of Session Layer Protocols of Internet of Things

    NARCIS (Netherlands)

    Köksal, Omer; Tekinerdogan, B.

    2017-01-01

    The Internet of Things (IoT) architecture is defined as a layered structure in which each layer represents a coherent set of services. For supporting the communication among the different IoT entities many different communication protocols are now available in practice. For practitioners, it is

  8. L2-LBMT: A Layered Load Balance Routing Protocol for underwater multimedia data transmission

    Science.gov (United States)

    Lv, Ze; Tang, Ruichun; Tao, Ye; Sun, Xin; Xu, Xiaowei

    2017-12-01

    Providing highly efficient underwater transmission of mass multimedia data is challenging due to the particularities of the underwater environment. Although there are many schemes proposed to optimize the underwater acoustic network communication protocols, from physical layer, data link layer, network layer to transport layer, the existing routing protocols for underwater wireless sensor network (UWSN) still cannot well deal with the problems in transmitting multimedia data because of the difficulties involved in high energy consumption, low transmission reliability or high transmission delay. It prevents us from applying underwater multimedia data to real-time monitoring of marine environment in practical application, especially in emergency search, rescue operation and military field. Therefore, the inefficient transmission of marine multimedia data has become a serious problem that needs to be solved urgently. In this paper, A Layered Load Balance Routing Protocol (L2-LBMT) is proposed for underwater multimedia data transmission. In L2-LBMT, we use layered and load-balance Ad Hoc Network to transmit data, and adopt segmented data reliable transfer (SDRT) protocol to improve the data transport reliability. And a 3-node variant of tornado (3-VT) code is also combined with the Ad Hoc Network to transmit little emergency data more quickly. The simulation results show that the proposed protocol can balance energy consumption of each node, effectively prolong the network lifetime and reduce transmission delay of marine multimedia data.

  9. Data distribution architecture based on standard real time protocol

    International Nuclear Information System (INIS)

    Castro, R.; Vega, J.; Pereira, A.; Portas, A.

    2009-01-01

    Data distribution architecture (DDAR) has been designed conforming to new requirements, taking into account the type of data that is going to be generated from experiments in International Thermonuclear Experimental Reactor (ITER). The main goal of this architecture is to implement a system that is able to manage on line all data that is being generated by an experiment, supporting its distribution for: processing, storing, analysing or visualizing. The first objective is to have a distribution architecture that supports long pulse experiments (even hours). The described system is able to distribute, using real time protocol (RTP), stored data or live data generated while the experiment is running. It enables researchers to access data on line instead of waiting for the end of the experiment. Other important objective is scalability, so the presented architecture can easily grow based on actual necessities, simplifying estimation and design tasks. A third important objective is security. In this sense, the architecture is based on standards, so complete security mechanisms can be applied, from secure transmission solutions until elaborated access control policies, and it is full compatible with multi-organization federation systems as PAPI or Shibboleth.

  10. Data distribution architecture based on standard real time protocol

    Energy Technology Data Exchange (ETDEWEB)

    Castro, R. [Asociacion EURATOM/CIEMAT para Fusion, Avda. Complutense No. 22, 28040 Madrid (Spain)], E-mail: rodrigo.castro@ciemat.es; Vega, J.; Pereira, A.; Portas, A. [Asociacion EURATOM/CIEMAT para Fusion, Avda. Complutense No. 22, 28040 Madrid (Spain)

    2009-06-15

    Data distribution architecture (DDAR) has been designed conforming to new requirements, taking into account the type of data that is going to be generated from experiments in International Thermonuclear Experimental Reactor (ITER). The main goal of this architecture is to implement a system that is able to manage on line all data that is being generated by an experiment, supporting its distribution for: processing, storing, analysing or visualizing. The first objective is to have a distribution architecture that supports long pulse experiments (even hours). The described system is able to distribute, using real time protocol (RTP), stored data or live data generated while the experiment is running. It enables researchers to access data on line instead of waiting for the end of the experiment. Other important objective is scalability, so the presented architecture can easily grow based on actual necessities, simplifying estimation and design tasks. A third important objective is security. In this sense, the architecture is based on standards, so complete security mechanisms can be applied, from secure transmission solutions until elaborated access control policies, and it is full compatible with multi-organization federation systems as PAPI or Shibboleth.

  11. Physical layer simulation study for the coexistence of WLAN standards

    Energy Technology Data Exchange (ETDEWEB)

    Howlader, M. K. [Marquette Univ., 222 Haggerty Hall, P. O. Box 1881, Milwaukee, WI 53201 (United States); Keiger, C. [Analysis and Measurement Services Corporation, 9111 Cross Park Drive, Knoxville, TN 37923 (United States); Ewing, P. D. [Oak Ridge National Laboratory, MS-6006, P. O. Box 2008, Oak Ridge, TN 37831 (United States); Govan, T. V. [U.S. Nuclear Regulatory Commission, MS T-10-D20, 11545 Rockville Pike, Rockville, MD 20852 (United States)

    2006-07-01

    This paper presents the results of a study on the performance of wireless local area network (WLAN) devices in the presence of interference from other wireless devices. To understand the coexistence of these wireless protocols, simplified physical-layer-system models were developed for the Bluetooth, Wireless Fidelity (WiFi), and Zigbee devices, all of which operate within the 2.4-GHz frequency band. The performances of these protocols were evaluated using Monte-Carlo simulations under various interference and channel conditions. The channel models considered were basic additive white Gaussian noise (AWGN), Rayleigh fading, and site-specific fading. The study also incorporated the basic modulation schemes, multiple access techniques, and channel allocations of the three protocols. This research is helping the U.S. Nuclear Regulatory Commission (NRC) understand the coexistence issues associated with deploying wireless devices and could prove useful in the development of a technical basis for guidance to address safety-related issues with the implementation of wireless systems in nuclear facilities. (authors)

  12. Physical layer simulation study for the coexistence of WLAN standards

    International Nuclear Information System (INIS)

    Howlader, M. K.; Keiger, C.; Ewing, P. D.; Govan, T. V.

    2006-01-01

    This paper presents the results of a study on the performance of wireless local area network (WLAN) devices in the presence of interference from other wireless devices. To understand the coexistence of these wireless protocols, simplified physical-layer-system models were developed for the Bluetooth, Wireless Fidelity (WiFi), and Zigbee devices, all of which operate within the 2.4-GHz frequency band. The performances of these protocols were evaluated using Monte-Carlo simulations under various interference and channel conditions. The channel models considered were basic additive white Gaussian noise (AWGN), Rayleigh fading, and site-specific fading. The study also incorporated the basic modulation schemes, multiple access techniques, and channel allocations of the three protocols. This research is helping the U.S. Nuclear Regulatory Commission (NRC) understand the coexistence issues associated with deploying wireless devices and could prove useful in the development of a technical basis for guidance to address safety-related issues with the implementation of wireless systems in nuclear facilities. (authors)

  13. An Energy-Efficient Link Layer Protocol for Reliable Transmission over Wireless Networks

    Directory of Open Access Journals (Sweden)

    Iqbal Adnan

    2009-01-01

    Full Text Available In multihop wireless networks, hop-by-hop reliability is generally achieved through positive acknowledgments at the MAC layer. However, positive acknowledgments introduce significant energy inefficiencies on battery-constrained devices. This inefficiency becomes particularly significant on high error rate channels. We propose to reduce the energy consumption during retransmissions using a novel protocol that localizes bit-errors at the MAC layer. The proposed protocol, referred to as Selective Retransmission using Virtual Fragmentation (SRVF, requires simple modifications to the positive-ACK-based reliability mechanism but provides substantial improvements in energy efficiency. The main premise of the protocol is to localize bit-errors by performing partial checksums on disjoint parts or virtual fragments of a packet. In case of error, only the corrupted virtual fragments are retransmitted. We develop stochastic models of the Simple Positive-ACK-based reliability, the previously-proposed Packet Length Optimization (PLO protocol, and the SRVF protocol operating over an arbitrary-order Markov wireless channel. Our analytical models show that SRVF provides significant theoretical improvements in energy efficiency over existing protocols. We then use bit-error traces collected over different real networks to empirically compare the proposed and existing protocols. These experimental results further substantiate that SRVF provides considerably better energy efficiency than Simple Positive-ACK and Packet Length Optimization protocols.

  14. An improved network layer protocol based on mobile IPv6

    Institute of Scientific and Technical Information of China (English)

    2001-01-01

    The mobile [Pv6 proposed by the IETF aims at providing mobility support on the next generation Internet. First, the authors described the basic principle of mobile lPv6 in brief and analyzed the advantages and disadvantages of it, presented a new idea of allocating a specific address space for mobile node ( MN ) and developed a new extension header and two ICMP message types for mobile IPv6. Lastly the authors proposed an optimization strategy, for mobile IPv6 based on these extensions of protocol, which has the following advantages:1 ) It is more convenient to manage the MNs because MN can be judged from its IP address; 2) When the correspondent node (CN) is not actively communicating with a MN, the MN and its home agent (HA) need not send Binding Update to tire CN, and the CN need not send Binding Request to the MN. Only when the CN really wants to send a packet to the MN, will the CN voluntarily send a MN Discover Request message to acquire the MN's care-of address. In this way, the transmission of Binding Update and Binding Request is greatly reduced, consequently the network overhead is also decreased; 3) While sending packets, the CN simply uses a MN Home Address Extension Header without using IPinlP encapsulation and routing header, which can reduce the redundant information in the packet and the message delay; 4) All the packets sent by the CN can be directly routed to the MN and the triangle routing can be completely avoided. By using these protocol extensions, the overhead of the network is greatly reduced and the network quality of services (QoS) is improved.

  15. The effect of personalized versus standard patient protocols for radiostereometric analysis (RSA)

    DEFF Research Database (Denmark)

    Muharemovic, O; Troelsen, A; Thomsen, M G

    2018-01-01

    INTRODUCTION: Increasing pressure in the clinic requires a more standardized approach to radiostereometric analysis (RSA) imaging. The aim of this study was to investigate whether implementation of personalized RSA patient protocols could increase image quality and decrease examination time...... imaging. Radiographers in the control group used a standard RSA protocol. RESULTS: At three months, radiographers in the case group significantly reduced (p .... No significant improvements were found in the control group at any time point. CONCLUSION: There is strong evidence that personalized RSA patient protocols have a positive effect on image quality and radiation dose savings. Implementation of personal patient protocols as a RSA standard will contribute...

  16. Development of a standard communication protocol for an emergency situation management in nuclear power plants

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Man Cheol, E-mail: charleskim@kaeri.re.k [Integrated Risk Assessment Center, Korea Atomic Energy Research Institute, 150, Deokjin-dong, Yuseong-gu, Daejeon 305-353 (Korea, Republic of); Park, Jinkyun; Jung, Wondea [Integrated Risk Assessment Center, Korea Atomic Energy Research Institute, 150, Deokjin-dong, Yuseong-gu, Daejeon 305-353 (Korea, Republic of); Kim, Hanjeom; Kim, Yoon Joong [YGN Nuclear Power Division Training Center, Korea Hydro and Nuclear Power Company, 517 Kyemari, Hongnong-eup, Yeongkwang-gun, Chonnam 513-880 (Korea, Republic of)

    2010-06-15

    Correct communication between main control room (MCR) operators is an important factor in the management of emergency situations in nuclear power plants (NPPs). For this reason, a standard communication protocol for the management of emergency situations in NPPs has been developed, with the basic direction of enhancing the safety of NPPs and the standardization of communication protocols. To validate the newly developed standard communication protocol, validation experiments with 10 licensed NPP MCR operator teams was performed. From the validation experiments, it was found that the use of the standard communication protocol required more time, but it can contribute to the enhancement of the safety of NPPs by an operators' better grasp of the safety-related parameters and a more efficient and clearer communication between NPP operators, while imposing little additional workloads on the NPP MCR operators. The standard communication protocol is expected to be used to train existing NPP MCR operators without much aversion, as well as new operators.

  17. Criteria for Evaluating Alternative Network and Link Layer Protocols for the NASA Constellation Program Communication Architecture

    Science.gov (United States)

    Benbenek, Daniel; Soloff, Jason; Lieb, Erica

    2010-01-01

    Selecting a communications and network architecture for future manned space flight requires an evaluation of the varying goals and objectives of the program, development of communications and network architecture evaluation criteria, and assessment of critical architecture trades. This paper uses Cx Program proposed exploration activities as a guideline; lunar sortie, outpost, Mars, and flexible path options are described. A set of proposed communications network architecture criteria are proposed and described. They include: interoperability, security, reliability, and ease of automating topology changes. Finally a key set of architecture options are traded including (1) multiplexing data at a common network layer vs. at the data link layer, (2) implementing multiple network layers vs. a single network layer, and (3) the use of a particular network layer protocol, primarily IPv6 vs. Delay Tolerant Networking (DTN). In summary, the protocol options are evaluated against the proposed exploration activities and their relative performance with respect to the criteria are assessed. An architectural approach which includes (a) the capability of multiplexing at both the network layer and the data link layer and (b) a single network layer for operations at each program phase, as these solutions are best suited to respond to the widest array of program needs and meet each of the evaluation criteria.

  18. A review on transport layer protocol performance for delivering video on an adhoc network

    Science.gov (United States)

    Suherman; Suwendri; Al-Akaidi, Marwan

    2017-09-01

    The transport layer protocol is responsible for the end to end data transmission. Transmission control protocol (TCP) provides a reliable connection and user datagram protocol (UDP) offers fast but unguaranteed data transfer. Meanwhile, the 802.11 (wireless fidelity/WiFi) networks have been widely used as internet hotspots. This paper evaluates TCP, TCP variants and UDP performances for video transmission on an adhoc network. The transport protocol - medium access cross-layer is proposed by prioritizing TCP acknowledgement to reduce delay. The NS-2 evaluations show that the average delays increase linearly for all the evaluated protocols and the average packet losses grow logarithmically. UDP produces the lowest transmission delay; 5.4% and 5.8% lower than TCP and TCP variant, but experiences the highest packet loss. Both TCP and TCP Vegas maintain packet loss as low as possible. The proposed cross-layer successfully decreases TCP and TCP Vegas delay about 0.12 % and 0.15%, although losses remain similar.

  19. Analytical approach to cross-layer protocol optimization in wireless sensor networks

    Science.gov (United States)

    Hortos, William S.

    2008-04-01

    In the distributed operations of route discovery and maintenance, strong interaction occurs across mobile ad hoc network (MANET) protocol layers. Quality of service (QoS) requirements of multimedia service classes must be satisfied by the cross-layer protocol, along with minimization of the distributed power consumption at nodes and along routes to battery-limited energy constraints. In previous work by the author, cross-layer interactions in the MANET protocol are modeled in terms of a set of concatenated design parameters and associated resource levels by multivariate point processes (MVPPs). Determination of the "best" cross-layer design is carried out using the optimal control of martingale representations of the MVPPs. In contrast to the competitive interaction among nodes in a MANET for multimedia services using limited resources, the interaction among the nodes of a wireless sensor network (WSN) is distributed and collaborative, based on the processing of data from a variety of sensors at nodes to satisfy common mission objectives. Sensor data originates at the nodes at the periphery of the WSN, is successively transported to other nodes for aggregation based on information-theoretic measures of correlation and ultimately sent as information to one or more destination (decision) nodes. The "multimedia services" in the MANET model are replaced by multiple types of sensors, e.g., audio, seismic, imaging, thermal, etc., at the nodes; the QoS metrics associated with MANETs become those associated with the quality of fused information flow, i.e., throughput, delay, packet error rate, data correlation, etc. Significantly, the essential analytical approach to MANET cross-layer optimization, now based on the MVPPs for discrete random events occurring in the WSN, can be applied to develop the stochastic characteristics and optimality conditions for cross-layer designs of sensor network protocols. Functional dependencies of WSN performance metrics are described in

  20. Surface metal standards produced by ion implantation through a removable layer

    International Nuclear Information System (INIS)

    Schueler, B.W.; Granger, C.N.; McCaig, L.; McKinley, J.M.; Metz, J.; Mowat, I.; Reich, D.F.; Smith, S.; Stevie, F.A.; Yang, M.H.

    2003-01-01

    Surface metal concentration standards were produced by ion implantation and investigated for their suitability to calibrate surface metal measurements by secondary ion mass spectrometry (SIMS). Single isotope implants were made through a 100 nm oxide layer on silicon. The implant energies were chosen to place the peak of the implanted species at a depth of 100 nm. Subsequent removal of the oxide layer was used to expose the implant peak and to produce controlled surface metal concentrations. Surface metal concentration measurements by time-of-flight SIMS (TOF-SIMS) with an analysis depth of 1 nm agreed with the expected surface concentrations of the implant standards with a relative mean standard deviation of 20%. Since the TOF-SIMS relative sensitivity factors (RSFs) were originally derived from surface metal measurements of surface contaminated silicon wafers, the agreement implies that the implant standards can be used to measure RSF values. The homogeneity of the surface metal concentration was typically <10%. The dopant dose remaining in silicon after oxide removal was measured using the surface-SIMS protocol. The measured implant dose agreed with the expected dose with a mean relative standard deviation of 25%

  1. A Brief Survey of Media Access Control, Data Link Layer, and Protocol Technologies for Lunar Surface Communications

    Science.gov (United States)

    Wallett, Thomas M.

    2009-01-01

    This paper surveys and describes some of the existing media access control and data link layer technologies for possible application in lunar surface communications and the advanced wideband Direct Sequence Code Division Multiple Access (DSCDMA) conceptual systems utilizing phased-array technology that will evolve in the next decade. Time Domain Multiple Access (TDMA) and Code Division Multiple Access (CDMA) are standard Media Access Control (MAC) techniques that can be incorporated into lunar surface communications architectures. Another novel hybrid technique that is recently being developed for use with smart antenna technology combines the advantages of CDMA with those of TDMA. The relatively new and sundry wireless LAN data link layer protocols that are continually under development offer distinct advantages for lunar surface applications over the legacy protocols which are not wireless. Also several communication transport and routing protocols can be chosen with characteristics commensurate with smart antenna systems to provide spacecraft communications for links exhibiting high capacity on the surface of the Moon. The proper choices depend on the specific communication requirements.

  2. A Standard Mutual Authentication Protocol for Cloud Computing Based Health Care System.

    Science.gov (United States)

    Mohit, Prerna; Amin, Ruhul; Karati, Arijit; Biswas, G P; Khan, Muhammad Khurram

    2017-04-01

    Telecare Medical Information System (TMIS) supports a standard platform to the patient for getting necessary medical treatment from the doctor(s) via Internet communication. Security protection is important for medical records (data) of the patients because of very sensitive information. Besides, patient anonymity is another most important property, which must be protected. Most recently, Chiou et al. suggested an authentication protocol for TMIS by utilizing the concept of cloud environment. They claimed that their protocol is patient anonymous and well security protected. We reviewed their protocol and found that it is completely insecure against patient anonymity. Further, the same protocol is not protected against mobile device stolen attack. In order to improve security level and complexity, we design a light weight authentication protocol for the same environment. Our security analysis ensures resilience of all possible security attacks. The performance of our protocol is relatively standard in comparison with the related previous research.

  3. OPTIMISATION OF BUFFER SIZE FOR ENHANCING QOS OF VIDEO TRAFFIC USING CROSS LAYERED HYBRID TRANSPORT LAYER PROTOCOL APPROACH

    Directory of Open Access Journals (Sweden)

    S. Matilda

    2011-03-01

    Full Text Available Video streaming is gaining importance, with the wide popularity of multimedia rich applications in the Internet. Video streams are delay sensitive and require seamless flow for continuous visualization. Properly designed buffers offer a solution to queuing delay. The diagonally opposite QoS metrics associated with video traffic poses an optimization problem, in the design of buffers. This paper is a continuation of our previous work [1] and deals with the design of buffers. It aims at finding the optimum buffer size for enhancing QoS offered to video traffic. Network-centric QoS provisioning approach, along with hybrid transport layer protocol approach is adopted, to arrive at an optimum size which is independent of RTT. In this combinational approach, buffers of routers and end devices are designed to satisfy the various QoS parameters at the transport layer. OPNET Modeler is used to simulate environments for testing the design. Based on the results of simulation it is evident that the hybrid transport layer protocol approach is best suited for transmitting video traffic as it supports the economical design.

  4. The effect of personalized versus standard patient protocols for radiostereometric analysis (RSA).

    Science.gov (United States)

    Muharemovic, O; Troelsen, A; Thomsen, M G; Kallemose, T; Gosvig, K K

    2018-05-01

    Increasing pressure in the clinic requires a more standardized approach to radiostereometric analysis (RSA) imaging. The aim of this study was to investigate whether implementation of personalized RSA patient protocols could increase image quality and decrease examination time and the number of exposure repetitions. Forty patients undergoing primary total hip arthroplasty were equally randomized to either a case or a control group. Radiographers in the case group were assisted by personalized patient protocols containing information about each patient's post-operative RSA imaging. Radiographers in the control group used a standard RSA protocol. At three months, radiographers in the case group significantly reduced (p RSA patient protocols have a positive effect on image quality and radiation dose savings. Implementation of personal patient protocols as a RSA standard will contribute to the reduction of examination time, thus ensuring a cost benefit for department and patient safety. Copyright © 2017 The College of Radiographers. Published by Elsevier Ltd. All rights reserved.

  5. Two-Layer Hierarchy Optimization Model for Communication Protocol in Railway Wireless Monitoring Networks

    Directory of Open Access Journals (Sweden)

    Xiaoping Ma

    2018-01-01

    Full Text Available The wireless monitoring system is always destroyed by the insufficient energy of the sensors in railway. Hence, how to optimize the communication protocol and extend the system lifetime is crucial to ensure the stability of system. However, the existing studies focused primarily on cluster-based or multihop protocols individually, which are ineffective in coping with the complex communication scenarios in the railway wireless monitoring system (RWMS. This study proposes a hybrid protocol which combines the cluster-based and multihop protocols (CMCP to minimize and balance the energy consumption in different sections of the RWMS. In the first hierarchy, the total energy consumption is minimized by optimizing the cluster quantities in the cluster-based protocol and the number of hops and the corresponding hop distances in the multihop protocol. In the second hierarchy, the energy consumption is balanced through rotating the cluster head (CH in the subnetworks and further optimizing the hops and the corresponding hop distances in the backbone network. On this basis, the system lifetime is maximized with the minimum and balance energy consumption among the sensors. Furthermore, the hybrid particle swarm optimization and genetic algorithm (PSO-GA are adopted to optimize the energy consumption from the two-layer hierarchy. Finally, the effectiveness of the proposed CMCP is verified in the simulation. The performances of the proposed CMCP in system lifetime, residual energy, and the corresponding variance are all superior to the LEACH protocol widely applied in the previous research. The effective protocol proposed in this study can facilitate the application of the wireless monitoring network in the railway system and enhance safety operation of the railway.

  6. An approach to standardization of urine sediment analysis via suggestion of a common manual protocol.

    Science.gov (United States)

    Ko, Dae-Hyun; Ji, Misuk; Kim, Sollip; Cho, Eun-Jung; Lee, Woochang; Yun, Yeo-Min; Chun, Sail; Min, Won-Ki

    2016-01-01

    The results of urine sediment analysis have been reported semiquantitatively. However, as recent guidelines recommend quantitative reporting of urine sediment, and with the development of automated urine sediment analyzers, there is an increasing need for quantitative analysis of urine sediment. Here, we developed a protocol for urine sediment analysis and quantified the results. Based on questionnaires, various reports, guidelines, and experimental results, we developed a protocol for urine sediment analysis. The results of this new protocol were compared with those obtained with a standardized chamber and an automated sediment analyzer. Reference intervals were also estimated using new protocol. We developed a protocol with centrifugation at 400 g for 5 min, with the average concentration factor of 30. The correlation between quantitative results of urine sediment analysis, the standardized chamber, and the automated sediment analyzer were generally good. The conversion factor derived from the new protocol showed a better fit with the results of manual count than the default conversion factor in the automated sediment analyzer. We developed a protocol for manual urine sediment analysis to quantitatively report the results. This protocol may provide a mean for standardization of urine sediment analysis.

  7. Shoulder muscle endurance: the development of a standardized and reliable protocol

    Directory of Open Access Journals (Sweden)

    Roy Jean-Sébastien

    2011-01-01

    Full Text Available Abstract Background Shoulder muscle fatigue has been proposed as a possible link to explain the association between repetitive arm use and the development of rotator cuff disorders. To our knowledge, no standardized clinical endurance protocol has been developed to evaluate the effects of muscle fatigue on shoulder function. Such a test could improve clinical examination of individuals with shoulder disorders. Therefore, the purpose of this study was to establish a reliable protocol for objective assessment of shoulder muscle endurance. Methods An endurance protocol was developed on a stationary dynamometer (Biodex System 3. The endurance protocol was performed in isotonic mode with the resistance set at 50% of each subject's peak torque as measured for shoulder external (ER and internal rotation (IR. Each subject performed 60 continuous repetitions of IR/ER rotation. The endurance protocol was performed by 36 healthy individuals on two separate occasions at least two days apart. Maximal isometric shoulder strength tests were performed before and after the fatigue protocol to evaluate the effects of the endurance protocol and its reliability. Paired t-tests were used to evaluate the reduction in shoulder strength due to the protocol, while intraclass correlation coefficients (ICC and minimal detectable change (MDC were used to evaluate its reliability. Results Maximal isometric strength was significantly decreased after the endurance protocol (P 0.84. Conclusions Changes in muscular performance observed during and after the muscular endurance protocol suggests that the protocol did result in muscular fatigue. Furthermore, this study established that the resultant effects of fatigue of the proposed isotonic protocol were reproducible over time. The protocol was performed without difficulty by all volunteers and took less than 10 minutes to perform, suggesting that it might be feasible for clinical practice. This protocol could be used to induce

  8. Network Layer Protocol Activation for Packet Data Access in UMTS WCDMA Laboratory Network

    OpenAIRE

    Lakkisto, Erkka

    2011-01-01

    The purpose of this Bachelor’s Thesis was to set up the UMTS WCDMA network in the laboratory environment of Helsinki Metropolia University of Applied Sciences and to study the network layer protocol activation for packet data access. The development of 3G technology has been very rapid and it can be considered as one of the main technologies in telecommunication. Implementing the laboratory network in Metropolia enables teaching and researching of the modern network technology. Labora...

  9. Comparison of different histological protocols for the preservation and quantification of the intestinal mucus layer in pigs

    Directory of Open Access Journals (Sweden)

    Ilen Röhe

    2018-02-01

    Full Text Available The histological characterization of the intestinal mucus layer is important for many scientific experiments investigating the interaction between intestinal microbiota, mucosal immune response and intestinal mucus production. The aim of this study was to examine and compare different fixation protocols for displaying and quantifying the intestinal mucus layer in piglets and to test which histomorphological parameters may correlate with the determined mucus layer thickness. Jejunal and colonal tissue samples of weaned piglets (n=10 were either frozen in liquid nitrogen or chemically fixed using methacarn solution. The frozen tissue samples were cryosectioned and subsequently postfixed using three different postfixatives: paraformaldehyde vapor, neutrally buffered formalin solution and ethanol solution. After dehydration, methacarn fixed tissues were embedded in paraffin wax. Both sections of cryopreserved and methacarn fixed tissue samples were stained with Alcian blue (AB-PAS followed by the microscopically determination of the mucus layer thickness. Different pH values of the Alcian Blue staining solution and two mucus layer thickness measuring methods were compared. In addition, various histomorphological parameters of methacarn fixed tissue samples were evaluated including the number of goblet cells and the mucin staining area. Cryopreservation in combination with chemical postfixation led to mucus preservation in the colon of piglets allowing mucus thickness measurements. Mucus could be only partly preserved in cryosections of the jejunum impeding any quantitative description of the mucus layer thickness. The application of different postfixations, varying pH values of the AB solution and different mucus layer measuring methods led to comparable results regarding the mucus layer thickness. Methacarn fixation proved to be unsuitable for mucus depiction as only mucus patches were found in the jejunum or a detachment of the mucus layer from

  10. Comparison of different histological protocols for the preservation and quantification of the intestinal mucus layer in pigs.

    Science.gov (United States)

    Röhe, Ilen; Hüttner, Friedrich Joseph; Plendl, Johanna; Drewes, Barbara; Zentek, Jürgen

    2018-02-05

    The histological characterization of the intestinal mucus layer is important for many scientific experiments investigating the interaction between intestinal microbiota, mucosal immune response and intestinal mucus production. The aim of this study was to examine and compare different fixation protocols for displaying and quantifying the intestinal mucus layer in piglets and to test which histomorphological parameters may correlate with the determined mucus layer thickness. Jejunal and colonal tissue samples of weaned piglets (n=10) were either frozen in liquid nitrogen or chemically fixed using methacarn solution. The frozen tissue samples were cryosectioned and subsequently postfixed using three different postfixatives: paraformaldehyde vapor, neutrally buffered formalin solution and ethanol solution. After dehydration, methacarn fixed tissues were embedded in paraffin wax. Both sections of cryopreserved and methacarn fixed tissue samples were stained with Alcian blue (AB)-PAS followed by the microscopically determination of the mucus layer thickness. Different pH values of the Alcian Blue staining solution and two mucus layer thickness measuring methods were compared. In addition, various histomorphological parameters of methacarn fixed tissue samples were evaluated including the number of goblet cells and the mucin staining area. Cryopreservation in combination with chemical postfixation led to mucus preservation in the colon of piglets allowing mucus thickness measurements. Mucus could be only partly preserved in cryosections of the jejunum impeding any quantitative description of the mucus layer thickness. The application of different postfixations, varying pH values of the AB solution and different mucus layer measuring methods led to comparable results regarding the mucus layer thickness. Methacarn fixation proved to be unsuitable for mucus depiction as only mucus patches were found in the jejunum or a detachment of the mucus layer from the epithelium was

  11. A Cross-Layer Duty Cycle MAC Protocol Supporting a Pipeline Feature for Wireless Sensor Networks

    Directory of Open Access Journals (Sweden)

    Young-Chon Kim

    2011-05-01

    Full Text Available Although the conventional duty cycle MAC protocols for Wireless Sensor Networks (WSNs such as RMAC perform well in terms of saving energy and reducing end-to-end delivery latency, they were designed independently and require an extra routing protocol in the network layer to provide path information for the MAC layer. In this paper, we propose a new cross-layer duty cycle MAC protocol with data forwarding supporting a pipeline feature (P-MAC for WSNs. P-MAC first divides the whole network into many grades around the sink. Each node identifies its grade according to its logical hop distance to the sink and simultaneously establishes a sleep/wakeup schedule using the grade information. Those nodes in the same grade keep the same schedule, which is staggered with the schedule of the nodes in the adjacent grade. Then a variation of the RTS/CTS handshake mechanism is used to forward data continuously in a pipeline fashion from the higher grade to the lower grade nodes and finally to the sink. No extra routing overhead is needed, thus increasing the network scalability while maintaining the superiority of duty-cycling. The simulation results in OPNET show that P-MAC has better performance than S-MAC and RMAC in terms of packet delivery latency and energy efficiency.

  12. A Standard Data Access Layer for Fusion Devices

    International Nuclear Information System (INIS)

    Neto, A.; Fernandes, H.; Valcarcel, D.; Varandas, C.; Vega, J.; Sanchez, E.; Pena, A.; Hron, M.

    2006-01-01

    Each EURATOM association stores data using proprietary schemes, usually developed by the research unit or using third party software. The temporary exchange of researchers between laboratories is a common practice nowadays. When the researchers returns to the home laboratory, usually there is the need to continue to follow the work started in the foreign country. The quantity of available data has also become enormous and the principal data index is changing from the shot number to time and events, where the shot number is just one of the most relevant. To solve these problems a common software layer between end-users and laboratories must exist. The components needed to create this software abstraction layer, between users and laboratories data, have already been developed using an universal and well known remote procedure call standard based on XML: XML-RPC. The library allows data retrieving using the same methods for all associations. Users are authenticated through the PAPI system (http://papi.rediris.es), allowing each organization to use its own authentication schema. Presently there are libraries and server implementations in Java and C++. These libraries have been included and tested in some of the most common data analysis programs like MatLab and IDL. The system is already being used in ISTTOK/PT and CASTOR/CZ. (author)

  13. Assessing impacts of roads: application of a standard assessment protocol

    Science.gov (United States)

    Duniway, Michael C.; Herrick, Jeffrey E.

    2013-01-01

    Adaptive management of road networks depends on timely data that accurately reflect the impacts those systems are having on ecosystem processes and associated services. In the absence of reliable data, land managers are left with little more than observations and perceptions to support management decisions of road-associated disturbances. Roads can negatively impact the soil, hydrologic, plant, and animal processes on which virtually all ecosystem services depend. The Interpreting Indicators of Rangeland Health (IIRH) protocol is a qualitative method that has been demonstrated to be effective in characterizing impacts of roads. The goal of this study were to develop, describe, and test an approach for using IIRH to systematically evaluate road impacts across large, diverse arid and semiarid landscapes. We developed a stratified random sampling approach to plot selection based on ecological potential, road inventory data, and image interpretation of road impacts. The test application on a semiarid landscape in southern New Mexico, United States, demonstrates that the approach developed is sensitive to road impacts across a broad range of ecological sites but that not all the types of stratification were useful. Ecological site and road inventory strata accounted for significant variability in the functioning of ecological processes but stratification based on apparent impact did not. Analysis of the repeatability of IIRH applied to road plots indicates that the method is repeatable but consensus evaluations based on multiple observers should be used to minimize risk of bias. Landscape-scale analysis of impacts by roads of contrasting designs (maintained dirt or gravel roads vs. non- or infrequently maintained roads) suggests that future travel management plans for the study area should consider concentrating traffic on fewer roads that are well designed and maintained. Application of the approach by land managers will likely provide important insights into

  14. Standardized cardiovascular magnetic resonance imaging (CMR protocols, society for cardiovascular magnetic resonance: board of trustees task force on standardized protocols

    Directory of Open Access Journals (Sweden)

    Kim Raymond J

    2008-07-01

    Full Text Available Index 1. General techniques 1.1. Stress and safety equipment 1.2. Left ventricular (LV structure and function module 1.3. Right ventricular (RV structure and function module 1.4. Gadolinium dosing module. 1.5. First pass perfusion 1.6. Late gadolinium enhancement (LGE 2. Disease specific protocols 2.1. Ischemic heart disease 2.1.1. Acute myocardial infarction (MI 2.1.2. Chronic ischemic heart disease and viability 2.1.3. Dobutamine stress 2.1.4. Adenosine stress perfusion 2.2. Angiography: 2.2.1. Peripheral magnetic resonance angiography (MRA 2.2.2. Thoracic MRA 2.2.3. Anomalous coronary arteries 2.2.4. Pulmonary vein evaluation 2.3. Other 2.3.1. Non-ischemic cardiomyopathy 2.3.2. Arrhythmogenic right ventricular cardiomyopathy (ARVC 2.3.3. Congenital heart disease 2.3.4. Valvular heart disease 2.3.5. Pericardial disease 2.3.6. Masses

  15. Asynchronous transfer mode and Local Area Network emulation standards, protocols, and security implications

    OpenAIRE

    Kirwin, John P.

    1999-01-01

    A complex networking technology called Asynchronous Transfer Mode (ATM) and a networking protocol called Local Area Network Emulation (LANE) are being integrated into many naval networks without any security-driven naval configuration guidelines. No single publication is available that describes security issues of data delivery and signaling relating to the transition of Ethernet to LANE and ATM. The thesis' focus is to provide: (1) an overview and security analysis of standardized protocols ...

  16. Adaptive MAC-layer protocol for multiservice digital access via tree and branch communication networks

    Science.gov (United States)

    Sriram, Kotikalapudi; Li, Chia-Chang; Magill, Peter; Whitaker, Norman A.; Dail, James E.; Dajer, Miguel A.; Siller, Curtis A.

    1995-11-01

    Described here is an adaptive MAC-layer protocol that supports multiservice (STM and ATM) applications in the context of subscriber access to tree and branch (e.g., fiber-coaxial cable) networks. The protocol adapts to changing demands for a mix of circuit and cell mode applications, and efficiently allocates upstream and downstream bandwidth to a variety of bursty and isochronous traffic sources. In the case of a hybrid fiber-coaxial (HFC) network the protocol resides in customer premises equipment and a common head-end controller. A medium-access control (MAC) processor provides for dividing the time domain for a given digital bitstream into successive frames, each with multiple STM and ATM time slots. Within the STM region of a frame, variable length time slots are allocated to calls (e.g., telephony, video telephony) requiring different amounts of bandwidth. A contention access signaling channel is also provided in this region for call control and set-up requests. Within the ATM region fixed-length time slots accommodate one individual ATM cell. These ATM time slots may be reserved for a user for the duration of a call or burst of successive ATM cells, or shared via a contention process. At least one contention time slot is available for signaling messages related to ATM call control and set-up requests. Further, the fixed-length ATM time slots may be reserved by a user for the duration of a call, or shared through a contention process. This paper describes the MAC-layer protocol, its relation to circuit- and ATM- amenable applications, and its performance with respect to signaling throughput and latency, and bandwidth efficiency for several service scenarios.

  17. Impact of Transport Layer Protocols on Reliable Information Access in Smart Grids

    DEFF Research Database (Denmark)

    Shahid, Kamal; Saeed, Aamir; Kristensen, Thomas le Fevre

    2017-01-01

    Time is critical for certain types of dynamic information (e.g. frequency control) in a smart grid scenario. The usefulness of such information depends upon the arrival within a specific frame of time, which in other case may not serve the purpose and effect controller’s performance....... The question is addressed by analyzing the performance of UDP and TCP over imperfect network conditions to show how the selection of transport layer protocol can dramatically affect controller’s performance. This analysis is based on a quality metric called mismatch probability that considers occurrence...

  18. Emotional assistance in thalassaemia: pilot implementation of a standard protocol

    Directory of Open Access Journals (Sweden)

    M.T. Veit

    2011-12-01

    Full Text Available This study aims to describe the creation process of standard procedures to make possible multicentre studies related to emotional aspects of thalassaemic patients, their families and caregivers; and the pilot phase of the routine implementation. The objectives defined to perform this goal are: i develop routines to assess and manage/treat emotional issues; ii adjust the ABRASTA - Brazilian Association of Thalassaemia computer system to the input of collected data and its compilation; iii conduct a pilot implementation of the routines; iv discuss the whole process and propose next steps. Forty patients were assisted following the above mentioned routines of psychological evaluation, follow-up assistance and management of specific emotional issues. Conclusions are that the routines are adequate to enable multicenter research to compare findings and develop specific interventions to Thalassaemia patients, their families and caregivers; information gathered through them is an important means of supporting medical doctors and other members of the professional team, both in the therapeutic planning and in the communication process with patients and families; finally, considering the nature of the information, psychologists and psychiatrists are the most indicated professionals to perform the assessment and the interventions related to emotional issues, due to their professional background, training and specific skills that allow a free and candid communication with the patients and their families. 本研究旨在描述标准程序的创造过程,来进行关于地中海贫血患者、其家属和照顾者情感方面可能的多中心研究;以及例程实施的试点阶段。 为实现此目的而定下的目标有: 1)制定例程评估和管理/处理情感问题;2)调整巴西地中海贫血病协会(ABRASTA)计算机系统, 输入收集到的数据并对其进行编辑;3)对例程进行试点实施;4)讨论整个过

  19. Inter-laboratory variation in DNA damage using a standard comet assay protocol

    DEFF Research Database (Denmark)

    Forchhammer, Lykke; Ersson, Clara; Loft, Steffen

    2012-01-01

    determined the baseline level of DNA strand breaks (SBs)/alkaline labile sites and formamidopyrimidine DNA glycosylase (FPG)-sensitive sites in coded samples of mononuclear blood cells (MNBCs) from healthy volunteers. There were technical problems in seven laboratories in adopting the standard protocol...... analysed by the standard protocol. The SBs and FPG-sensitive sites were measured in the same experiment, indicating that the large spread in the latter lesions was the main reason for the reduced inter-laboratory variation. However, it remains worrying that half of the participating laboratories obtained...

  20. Selecting corporate political tactics: The Montreal Protocol on substances that deplete the ozone layer

    International Nuclear Information System (INIS)

    Getz, K.A.

    1991-01-01

    This study examines factors influencing the choice of one set of tactics over others. The case of ozone depletion is used as the research context, and the data are drawn from US companies having a stake in this issue. A model is developed which suggests that a firm's choice of political tactics (dependent variable) is dependent on the targets of political activity and the nature of the issue of concern (independent variables), and a variety of organizational and industry factors (moderating variables). The paradigm of agency is used to systematically assess the relative importance of these factors. To test the relevance of the model, an empirical study was done. The case of the Montreal protocol on Substances That Deplete the Ozone Layer was chosen as a setting; and 551 firms directly affected by policy intended to protect the ozone layer were surveyed. There were 151 usable responses. Generally, the findings were consistent with the model

  1. A Standardized Protocol for the Prospective Follow-Up of Cleft Lip and Palate Patients.

    Science.gov (United States)

    Salimi, Negar; Jolanta, Aleksejūnienė; Edwin, Yen; Angelina, Loo

    2018-01-01

    To develop a standardized all-encompassing protocol for the assessment of cleft lip and palate patients with clinical and research implications. Electronic database searches were conducted and 13 major cleft centers worldwide were contacted in order to prepare for the development of the protocol. In preparation, the available evidence was reviewed and potential fistula-related risk determinants from 4 different domains were identified. No standardized protocol for the assessment of cleft patients could be found in any of the electronic database searches that were conducted. Interviews with representatives from several major centers revealed that the majority of centers do not have a standardized comprehensive strategy for the reporting and follow-up of cleft lip and palate patients. The protocol was developed and consisted of the following domains of determinants: (1) the sociodemographic domain, (2) the cleft defect domain, (3) the surgery domain, and (4) the fistula domain. The proposed protocol has the potential to enhance the quality of patient care by ensuring that multiple patient-related aspects are consistently reported. It may also facilitate future multicenter research, which could contribute to the reduction of fistula occurrence in cleft lip and palate patients.

  2. Security analysis of standards-driven communication protocols for healthcare scenarios.

    Science.gov (United States)

    Masi, Massimiliano; Pugliese, Rosario; Tiezzi, Francesco

    2012-12-01

    The importance of the Electronic Health Record (EHR), that stores all healthcare-related data belonging to a patient, has been recognised in recent years by governments, institutions and industry. Initiatives like the Integrating the Healthcare Enterprise (IHE) have been developed for the definition of standard methodologies for secure and interoperable EHR exchanges among clinics and hospitals. Using the requisites specified by these initiatives, many large scale projects have been set up for enabling healthcare professionals to handle patients' EHRs. The success of applications developed in these contexts crucially depends on ensuring such security properties as confidentiality, authentication, and authorization. In this paper, we first propose a communication protocol, based on the IHE specifications, for authenticating healthcare professionals and assuring patients' safety. By means of a formal analysis carried out by using the specification language COWS and the model checker CMC, we reveal a security flaw in the protocol thus demonstrating that to simply adopt the international standards does not guarantee the absence of such type of flaws. We then propose how to emend the IHE specifications and modify the protocol accordingly. Finally, we show how to tailor our protocol for application to more critical scenarios with no assumptions on the communication channels. To demonstrate feasibility and effectiveness of our protocols we have fully implemented them.

  3. A standard protocol for describing individual-based and agent-based models

    Science.gov (United States)

    Grimm, Volker; Berger, Uta; Bastiansen, Finn; Eliassen, Sigrunn; Ginot, Vincent; Giske, Jarl; Goss-Custard, John; Grand, Tamara; Heinz, Simone K.; Huse, Geir; Huth, Andreas; Jepsen, Jane U.; Jorgensen, Christian; Mooij, Wolf M.; Muller, Birgit; Pe'er, Guy; Piou, Cyril; Railsback, Steven F.; Robbins, Andrew M.; Robbins, Martha M.; Rossmanith, Eva; Ruger, Nadja; Strand, Espen; Souissi, Sami; Stillman, Richard A.; Vabo, Rune; Visser, Ute; DeAngelis, Donald L.

    2006-01-01

    Simulation models that describe autonomous individual organisms (individual based models, IBM) or agents (agent-based models, ABM) have become a widely used tool, not only in ecology, but also in many other disciplines dealing with complex systems made up of autonomous entities. However, there is no standard protocol for describing such simulation models, which can make them difficult to understand and to duplicate. This paper presents a proposed standard protocol, ODD, for describing IBMs and ABMs, developed and tested by 28 modellers who cover a wide range of fields within ecology. This protocol consists of three blocks (Overview, Design concepts, and Details), which are subdivided into seven elements: Purpose, State variables and scales, Process overview and scheduling, Design concepts, Initialization, Input, and Submodels. We explain which aspects of a model should be described in each element, and we present an example to illustrate the protocol in use. In addition, 19 examples are available in an Online Appendix. We consider ODD as a first step for establishing a more detailed common format of the description of IBMs and ABMs. Once initiated, the protocol will hopefully evolve as it becomes used by a sufficiently large proportion of modellers.

  4. Improving treatment times for patients with in-hospital stroke using a standardized protocol.

    Science.gov (United States)

    Koge, Junpei; Matsumoto, Shoji; Nakahara, Ichiro; Ishii, Akira; Hatano, Taketo; Sadamasa, Nobutake; Kai, Yasutoshi; Ando, Mitsushige; Saka, Makoto; Chihara, Hideo; Takita, Wataru; Tokunaga, Keisuke; Kamata, Takahiko; Nishi, Hidehisa; Hashimoto, Tetsuya; Tsujimoto, Atsushi; Kira, Jun-Ichi; Nagata, Izumi

    2017-10-15

    Previous reports have shown significant delays in treatment of in-hospital stroke (IHS). We developed and implemented our IHS alert protocol in April 2014. We aimed to determine the influence of implementation of our IHS alert protocol. Our implementation processes comprise the following four main steps: IHS protocol development, workshops for hospital staff to learn about the protocol, preparation of standardized IHS treatment kits, and obtaining feedback in a monthly hospital staff conference. We retrospectively compared protocol metrics and clinical outcomes of patients with IHS treated with intravenous thrombolysis and/or endovascular therapy between before (January 2008-March 2014) and after implementation (April 2014-December 2016). Fifty-five patients were included (pre, 25; post, 30). After the implementation, significant reductions occurred in the median time from stroke recognition to evaluation by a neurologist (30 vs. 13.5min, pvs. 26.5min, pvs. 16min, p=0.02). The median time from first neuroimaging to endovascular therapy had a tendency to decrease (75 vs. 53min, p=0.08). There were no differences in the favorable outcomes (modified Rankin scale score of 0-2) at discharge or the incidence of symptomatic intracranial hemorrhage between the two periods. Our IHS alert protocol implementation saved time in treating patients with IHS without compromising safety. Copyright © 2017 Elsevier B.V. All rights reserved.

  5. Normalization of cortical thickness measurements across different T1 magnetic resonance imaging protocols by novel W-Score standardization.

    Science.gov (United States)

    Chung, Jinyong; Yoo, Kwangsun; Lee, Peter; Kim, Chan Mi; Roh, Jee Hoon; Park, Ji Eun; Kim, Sang Joon; Seo, Sang Won; Shin, Jeong-Hyeon; Seong, Joon-Kyung; Jeong, Yong

    2017-10-01

    The use of different 3D T1-weighted magnetic resonance (T1 MR) imaging protocols induces image incompatibility across multicenter studies, negating the many advantages of multicenter studies. A few methods have been developed to address this problem, but significant image incompatibility still remains. Thus, we developed a novel and convenient method to improve image compatibility. W-score standardization creates quality reference values by using a healthy group to obtain normalized disease values. We developed a protocol-specific w-score standardization to control the protocol effect, which is applied to each protocol separately. We used three data sets. In dataset 1, brain T1 MR images of normal controls (NC) and patients with Alzheimer's disease (AD) from two centers, acquired with different T1 MR protocols, were used (Protocol 1 and 2, n = 45/group). In dataset 2, data from six subjects, who underwent MRI with two different protocols (Protocol 1 and 2), were used with different repetition times, echo times, and slice thicknesses. In dataset 3, T1 MR images from a large number of healthy normal controls (Protocol 1: n = 148, Protocol 2: n = 343) were collected for w-score standardization. The protocol effect and disease effect on subjects' cortical thickness were analyzed before and after the application of protocol-specific w-score standardization. As expected, different protocols resulted in differing cortical thickness measurements in both NC and AD subjects. Different measurements were obtained for the same subject when imaged with different protocols. Multivariate pattern difference between measurements was observed between the protocols. Classification accuracy between two protocols was nearly 90%. After applying protocol-specific w-score standardization, the differences between the protocols substantially decreased. Most importantly, protocol-specific w-score standardization reduced both univariate and multivariate differences in the images while

  6. Standardization of a Videofluoroscopic Swallow Study Protocol to Investigate Dysphagia in Dogs.

    Science.gov (United States)

    Harris, R A; Grobman, M E; Allen, M J; Schachtel, J; Rawson, N E; Bennett, B; Ledyayev, J; Hopewell, B; Coates, J R; Reinero, C R; Lever, T E

    2017-03-01

    Videofluoroscopic swallow study (VFSS) is the gold standard for diagnosis of dysphagia in veterinary medicine but lacks standardized protocols that emulate physiologic feeding practices. Age impacts swallow function in humans but has not been evaluated by VFSS in dogs. To develop a protocol with custom kennels designed to allow free-feeding of 3 optimized formulations of contrast media and diets that address limitations of current VFSS protocols. We hypothesized that dogs evaluated by a free-feeding VFSS protocol would show differences in objective swallow metrics based on age. Healthy juvenile, adult, and geriatric dogs (n = 24). Prospective, experimental study. Custom kennels were developed to maintain natural feeding behaviors during VFSS. Three food consistencies (thin liquid, pureed food, and dry kibble) were formulated with either iohexol or barium to maximize palatability and voluntary prehension. Dogs were evaluated by 16 swallow metrics and compared across age groups. Development of a standardized VFSS protocol resulted in successful collection of swallow data in healthy dogs. No significant differences in swallow metrics were observed among age groups. Substantial variability was observed in healthy dogs when evaluated under these physiologic conditions. Features typically attributed to pathologic states, such as gastric reflux, were seen in healthy dogs. Development of a VFSS protocol that reflects natural feeding practices may allow emulation of physiology resulting in clinical signs of dysphagia. Age did not result in significant changes in swallow metrics, but additional studies are needed, particularly in light of substantial normal variation. Copyright © 2017 The Authors. Journal of Veterinary Internal Medicine published by Wiley Periodicals, Inc. on behalf of the American College of Veterinary Internal Medicine.

  7. A Survey on Application Layer Protocols for the Internet of Things

    OpenAIRE

    Karagiannis, Vasileios; Chatzimisios, Periklis; Vázquez-Gallego, Francisco; Alonso-Zárate, Jesús

    2015-01-01

    It has been more than fifteen years since the term Internet of Things (IoT) was introduced to the public. However, despite the efforts of research groups and innovative corporations, still today it is not possible to say that IoT is upon us. This is mainly due to the fact that a unified IoT architecture has not been yet clearly defined and there is no common agreement in defining protocols and standards for all IoT parts. The framework that current IoT platforms use consists mostly in technol...

  8. Comparison of a new whole-body continuous-table-movement protocol versus a standard whole-body MR protocol for the assessment of multiple myeloma

    International Nuclear Information System (INIS)

    Weckbach, S.; Michaely, H.J.; Schoenberg, S.O.; Dinter, D.J.; Stemmer, A.

    2010-01-01

    To evaluate a whole body (WB) continuous-table-movement (CTM) MR protocol for the assessment of multiple myeloma (MM) in comparison to a step-by-step WB protocol. Eighteen patients with MM were examined at 1.5T using a WB CTM protocol (axial T2-w fs BLADE, T1-w GRE sequence) and a step-by-step WB protocol including coronal/sagittal T1-w SE and STIR sequences as reference. Protocol time was assessed. Image quality, artefacts, liver/spleen assessability, and the ability to depict bone marrow lesions less than or greater than 1 cm as well as diffuse infiltration and soft tissue lesions were rated. Potential changes in the Durie and Salmon Plus stage and the detectability of complications were assessed. Mean protocol time was 6:38 min (CTM) compared to 24:32 min (standard). Image quality was comparable. Artefacts were more prominent using the CTM protocol (P = 0.0039). Organ assessability was better using the CTM protocol (P < 0.001). Depiction of bone marrow and soft tissue lesions was identical without a staging shift. Vertebral fractures were not detected using the CTM protocol. The new protocol allows a higher patient throughput and facilitates the depiction of extramedullary lesions. However, as long as vertebral fractures are not detectable, the protocol cannot be safely used for clinical routine without the acquisition of an additional sagittal sequence. (orig.)

  9. Improving post-stroke dysphagia outcomes through a standardized and multidisciplinary protocol: an exploratory cohort study.

    Science.gov (United States)

    Gandolfi, Marialuisa; Smania, Nicola; Bisoffi, Giulia; Squaquara, Teresa; Zuccher, Paola; Mazzucco, Sara

    2014-12-01

    Stroke is a major cause of dysphagia. Few studies to date have reported on standardized multidisciplinary protocolized approaches to the management of post-stroke dysphagia. The aim of this retrospective cohort study was to evaluate the impact of a standardized multidisciplinary protocol on clinical outcomes in patients with post-stroke dysphagia. We performed retrospective chart reviews of patients with post-stroke dysphagia admitted to the neurological ward of Verona University Hospital from 2004 to 2008. Outcomes after usual treatment for dysphagia (T- group) were compared versus outcomes after treatment under a standardized diagnostic and rehabilitative multidisciplinary protocol (T+ group). Outcome measures were death, pneumonia on X-ray, need for respiratory support, and proportion of patients on tube feeding at discharge. Of the 378 patients admitted with stroke, 84 had dysphagia and were enrolled in the study. A significantly lower risk of in-hospital death (odds ratio [OR] 0.20 [0.53-0.78]), pneumonia (OR 0.33 [0.10-1.03]), need for respiratory support (OR 0.48 [0.14-1.66]), and tube feeding at discharge (OR 0.30 [0.09-0.91]) was recorded for the T+ group (N = 39) as compared to the T- group (N = 45). The adjusted OR showed no difference between the two groups for in-hospital death and tube feeding at discharge. Use of a standardized multidisciplinary protocolized approach to the management of post-stroke dysphagia may significantly reduce rates of aspiration pneumonia, in-hospital mortality, and tube feeding in dysphagic stroke survivors. Consistent with the study's exploratory purposes, our findings suggest that the multidisciplinary protocol applied in this study offers an effective model of management of post-stroke dysphagia.

  10. Importance of Standardized DXA Protocol for Assessing Physique Changes in Athletes.

    Science.gov (United States)

    Nana, Alisa; Slater, Gary J; Hopkins, Will G; Halson, Shona L; Martin, David T; West, Nicholas P; Burke, Louise M

    2016-06-01

    The implications of undertaking DXA scans using best practice protocols (subjects fasted and rested) or a less precise but more practical protocol in assessing chronic changes in body composition following training and a specialized recovery technique were investigated. Twenty-one male cyclists completed an overload training program, in which they were randomized to four sessions per week of either cold water immersion therapy or control groups. Whole-body DXA scans were undertaken with best practice protocol (Best) or random activity protocol (Random) at baseline, after 3 weeks of overload training, and after a 2-week taper. Magnitudes of changes in total, lean and fat mass from baseline-overload, overload-taper and baseline-taper were assessed by standardization (Δmean/SD). The standard deviations of change scores for total and fat-free soft tissue mass (FFST) from Random scans (2-3%) were approximately double those observed in the Best (1-2%), owing to extra random errors associated with Random scans at baseline. There was little difference in change scores for fat mass. The effect of cold water immersion therapy on baseline-taper changes in FFST was possibly harmful (-0.7%; 90% confidence limits ±1.2%) with Best scans but unclear with Random scans (0.9%; ±2.0%). Both protocols gave similar possibly harmful effects of cold water immersion therapy on changes in fat mass (6.9%; ±13.5% and 5.5%; ±14.3%, respectively). An interesting effect of cold water immersion therapy on training-induced changes in body composition might have been missed with a less precise scanning protocol. DXA scans should be undertaken with Best.

  11. Beyond communication: the role of standardized protocols in a changing health care environment.

    Science.gov (United States)

    Vardaman, James M; Cornell, Paul; Gondo, Maria B; Amis, John M; Townsend-Gervis, Mary; Thetford, Carol

    2012-01-01

    Communication errors have grave consequences in health care settings. The situation-background-assessment-recommendation (SBAR) protocol has been theorized to improve communication by creating a common language between nurses and physicians in acute care situations. This practice is gaining acceptance across the health care field. However, as yet, there has been little investigation of the ways in which SBAR may have an impact on how health care professionals operate beyond the creation of a common language. The purposes of the study were to explore the implementation of the SBAR protocol and investigate the potential impact of SBAR on the day-to-day experiences of nurses. We performed a qualitative case study of 2 hospitals that were implementing the SBAR protocol. We collected data from 80 semistructured interviews with nurses, nurse manager, and physicians; observation of nursing and other hospital activities; and documents that pertained to the implementation of the SBAR protocol. Data were analyzed using a thematic approach. Our analysis revealed 4 dimensions of impact that SBAR has beyond its use as a communication tool: schema formation, development of legitimacy, development of social capital, and reinforcement of dominant logics. The results indicate that SBAR may function as more than a tool to standardize communication among nurses and physicians. Rather, the findings indicate that SBAR may aid in schema development that allows rapid decision making by nurses, provide social capital and legitimacy for less-tenured nurses, and reinforce a move toward standardization in the nursing profession. Our findings further suggest that standardized protocols such as SBAR may be a cost-effective method for hospital managers and administrators to accelerate the socialization of nurses, particularly new hires.

  12. Cross-layer protocol design for QoS optimization in real-time wireless sensor networks

    Science.gov (United States)

    Hortos, William S.

    2010-04-01

    The metrics of quality of service (QoS) for each sensor type in a wireless sensor network can be associated with metrics for multimedia that describe the quality of fused information, e.g., throughput, delay, jitter, packet error rate, information correlation, etc. These QoS metrics are typically set at the highest, or application, layer of the protocol stack to ensure that performance requirements for each type of sensor data are satisfied. Application-layer metrics, in turn, depend on the support of the lower protocol layers: session, transport, network, data link (MAC), and physical. The dependencies of the QoS metrics on the performance of the higher layers of the Open System Interconnection (OSI) reference model of the WSN protocol, together with that of the lower three layers, are the basis for a comprehensive approach to QoS optimization for multiple sensor types in a general WSN model. The cross-layer design accounts for the distributed power consumption along energy-constrained routes and their constituent nodes. Following the author's previous work, the cross-layer interactions in the WSN protocol are represented by a set of concatenated protocol parameters and enabling resource levels. The "best" cross-layer designs to achieve optimal QoS are established by applying the general theory of martingale representations to the parameterized multivariate point processes (MVPPs) for discrete random events occurring in the WSN. Adaptive control of network behavior through the cross-layer design is realized through the parametric factorization of the stochastic conditional rates of the MVPPs. The cross-layer protocol parameters for optimal QoS are determined in terms of solutions to stochastic dynamic programming conditions derived from models of transient flows for heterogeneous sensor data and aggregate information over a finite time horizon. Markov state processes, embedded within the complex combinatorial history of WSN events, are more computationally

  13. Evaluation of Dogs with Border Collie Collapse, Including Response to Two Standardized Strenuous Exercise Protocols.

    Science.gov (United States)

    Taylor, Susan; Shmon, Cindy; Su, Lillian; Epp, Tasha; Minor, Katie; Mickelson, James; Patterson, Edward; Shelton, G Diane

    2016-01-01

    Clinical and metabolic variables were evaluated in 13 dogs with border collie collapse (BCC) before, during, and following completion of standardized strenuous exercise protocols. Six dogs participated in a ball-retrieving protocol, and seven dogs participated in a sheep-herding protocol. Findings were compared with 16 normal border collies participating in the same exercise protocols (11 retrieving, five herding). Twelve dogs with BCC developed abnormal mentation and/or an abnormal gait during evaluation. All dogs had post-exercise elevations in rectal temperature, pulse rate, arterial blood pH, PaO2, and lactate, and decreased PaCO2 and bicarbonate, as expected with strenuous exercise, but there were no significant differences between BCC dogs and normal dogs. Electrocardiography demonstrated sinus tachycardia in all dogs following exercise. Needle electromyography was normal, and evaluation of muscle biopsy cryosections using a standard panel of histochemical stains and reactions did not reveal a reason for collapse in 10 dogs with BCC in which these tests were performed. Genetic testing excluded the dynamin-1 related exercise-induced collapse mutation and the V547A malignant hyperthermia mutation as the cause of BCC. Common reasons for exercise intolerance were eliminated. Although a genetic basis is suspected, the cause of collapse in BCC was not determined.

  14. Adaptive behaviors of experts in following standard protocol in trauma management: implications for developing flexible guidelines.

    Science.gov (United States)

    Vankipuram, Mithra; Ghaemmaghami, Vafa; Patel, Vimla L

    2012-01-01

    Critical care environments are complex and dynamic. To adapt to such environments, clinicians may be required to make alterations to their workflows resulting in deviations from standard procedures. In this work, deviations from standards in trauma critical care are studied. Thirty trauma cases were observed in a Level 1 trauma center. Activities tracked were compared to the Advance Trauma Life Support standard to determine (i) if deviations had occurred, (ii) type of deviations and (iii) whether deviations were initiated by individuals or collaboratively by the team. Results show that expert clinicians deviated to innovate, while deviations of novices result mostly in error. Experts' well developed knowledge allows for flexibility and adaptiveness in dealing with standards, resulting in innovative deviations while minimizing errors made. Providing informatics solution, in such a setting, would mean that standard protocols would have be flexible enough to "learn" from new knowledge, yet provide strong support for the trainees.

  15. A Standardized and Reproducible Urine Preparation Protocol for Cancer Biomarkers Discovery

    Directory of Open Access Journals (Sweden)

    Julia Beretov

    2014-01-01

    Full Text Available A suitable and standardized protein purification technique is essential to maintain consistency and to allow data comparison between proteomic studies for urine biomarker discovery. Ultimately, efforts should be made to standardize urine preparation protocols. The aim of this study was to develop an optimal analytical protocol to achieve maximal protein yield and to ensure that this method was applicable to examine urine protein patterns that distinguish disease and disease-free states. In this pilot study, we compared seven different urine sample preparation methods to remove salts, and to precipitate and isolate urinary proteins. Sodium dodecyl sulfate-polyacrylamide gel electrophoresis (SDS-PAGE profiles showed that the sequential preparation of urinary proteins by combining acetone and trichloroacetic acid (TCA alongside high speed centrifugation (HSC provided the best separation, and retained the most urinary proteins. Therefore, this approach is the preferred method for all further urine protein analysis.

  16. Use of a Microprocessor to Implement an ADCCP Protocol (Federal Standard 1003).

    Science.gov (United States)

    1980-07-01

    results of other studies, to evaluate the operational and economic impact of incorporating various options in Federal Standard 1003. The effort...the LSI interface and the microprocessor; the LSI chip deposits bytes in its buffer as the producer, and the MPU reads this data as the consumer...on the interface between the MPU and the LSI protocol chip. This requires two main processes to be running at the same time--transmit and receive. The

  17. The impact of a new standard labor protocol on maternal and neonatal outcomes.

    Science.gov (United States)

    Wang, Dingran; Ye, Shenglong; Tao, Liyuan; Wang, Yongqing

    2017-12-01

    To analyze the clinical outcomes following the implementation of a new standard labor procedure. This was a retrospective analysis that included a study group consisting of patients managed based on a new standard labor protocol and a control group comprising patients managed under an old standard labor protocol. The following maternal and perinatal outcomes were compared in the two groups: the indications for a cesarean section and the incidence of cesarean section, postpartum hemorrhage, fetal distress, neonatal asphyxia and pediatric intervention. We also compared the average number of days spent in the hospital, the incidence of medical disputes and hospitalization expenses. The cesarean section rates for the study and control groups were 19.29% (401/2079) and 33.53% (753/2246), respectively (P labor, fetal distress and intrapartum fever; the percentages of each indication were significantly different from those of the control group (P labor protocol reduced the cesarean section rate without negatively impacting maternal and neonatal outcomes. In practice, bed turnover and the hospital utilization rate should be better controlled, patient-doctor communication should be strengthened and the quality of obstetrical service should be improved.

  18. Standard protocol for evaluation of environmental transfer factors around NPP sites

    International Nuclear Information System (INIS)

    Hegde, A.G.; Verma, P.C.; Rao, D.D.

    2009-01-01

    This document presents the standard procedures for evaluation of site specific environmental transfer factors around NPP sites. The scope of this document is to provide standard protocol to be followed for evaluation of environmental transfer factors around NPP sites. The studies on transfer factors are being carried out at various NPP sites under DAE-BRNS projects for evaluation of site specific transfer factors for radionuclides released from power plants. This document contains a common methodology in terms of sampling, processing, measurements and analysis of elemental/radionuclides, while keeping the site specific requirements also in place. (author)

  19. Standard protocol for conducting pre-operational environmental surveillance around nuclear facilities

    Energy Technology Data Exchange (ETDEWEB)

    Hegde, A G; Verma, P C; Rajan, M P [Health Safety and Environment Group, Bhabha Atomic Research Centre, Mumbai (India)

    2009-02-15

    This document presents the standard procedures for evaluation of site specific environmental transfer factors around NPP sites. The scope of this document is to provide standard protocol to be followed for conducting pre-operational environmental surveillance around nuclear facilities. Such surveillances have been proposed to be carried out by university professionals under DAE-BRNS projects. This document contains a common methodology in terms of sampling, processing, measurements and analysis of elemental/radionuclides, while keeping the site specific requirements also in place. (author)

  20. Standard protocol for conducting pre-operational environmental surveillance around nuclear facilities

    International Nuclear Information System (INIS)

    Hegde, A.G.; Verma, P.C.; Rajan, M.P.

    2009-02-01

    This document presents the standard procedures for evaluation of site specific environmental transfer factors around NPP sites. The scope of this document is to provide standard protocol to be followed for conducting pre-operational environmental surveillance around nuclear facilities. Such surveillances have been proposed to be carried out by university professionals under DAE-BRNS projects. This document contains a common methodology in terms of sampling, processing, measurements and analysis of elemental/radionuclides, while keeping the site specific requirements also in place. (author)

  1. Protocol for Usability Testing and Validation of the ISO Draft International Standard 19223 for Lung Ventilators

    Science.gov (United States)

    2017-01-01

    Background Clinicians, such as respiratory therapists and physicians, are often required to set up pieces of medical equipment that use inconsistent terminology. Current lung ventilator terminology that is used by different manufacturers contributes to the risk of usage errors, and in turn the risk of ventilator-associated lung injuries and other conditions. Human factors and communication issues are often associated with ventilator-related sentinel events, and inconsistent ventilator terminology compounds these issues. This paper describes our proposed protocol, which will be implemented at the University of Waterloo, Canada when this project is externally funded. Objective We propose to determine whether a standardized vocabulary improves the ease of use, safety, and utility as it relates to the usability of medical devices, compared to legacy medical devices from multiple manufacturers, which use different terms. Methods We hypothesize that usage errors by clinicians will be lower when standardization is consistently applied by all manufacturers. The proposed study will experimentally examine the impact of standardized nomenclature on performance declines in the use of an unfamiliar ventilator product in clinically relevant scenarios. Participants will be respiratory therapy practitioners and trainees, and we propose studying approximately 60 participants. Results The work reported here is in the proposal phase. Once the protocol is implemented, we will report the results in a follow-up paper. Conclusions The proposed study will help us better understand the effects of standardization on medical device usability. The study will also help identify any terms in the International Organization for Standardization (ISO) Draft International Standard (DIS) 19223 that may be associated with recurrent errors. Amendments to the standard will be proposed if recurrent errors are identified. This report contributes a protocol that can be used to assess the effect of

  2. Why standard brain-computer interface (BCI) training protocols should be changed: an experimental study

    Science.gov (United States)

    Jeunet, Camille; Jahanpour, Emilie; Lotte, Fabien

    2016-06-01

    Objective. While promising, electroencephaloraphy based brain-computer interfaces (BCIs) are barely used due to their lack of reliability: 15% to 30% of users are unable to control a BCI. Standard training protocols may be partly responsible as they do not satisfy recommendations from psychology. Our main objective was to determine in practice to what extent standard training protocols impact users’ motor imagery based BCI (MI-BCI) control performance. Approach. We performed two experiments. The first consisted in evaluating the efficiency of a standard BCI training protocol for the acquisition of non-BCI related skills in a BCI-free context, which enabled us to rule out the possible impact of BCIs on the training outcome. Thus, participants (N = 54) were asked to perform simple motor tasks. The second experiment was aimed at measuring the correlations between motor tasks and MI-BCI performance. The ten best and ten worst performers of the first study were recruited for an MI-BCI experiment during which they had to learn to perform two MI tasks. We also assessed users’ spatial ability and pre-training μ rhythm amplitude, as both have been related to MI-BCI performance in the literature. Main results. Around 17% of the participants were unable to learn to perform the motor tasks, which is close to the BCI illiteracy rate. This suggests that standard training protocols are suboptimal for skill teaching. No correlation was found between motor tasks and MI-BCI performance. However, spatial ability played an important role in MI-BCI performance. In addition, once the spatial ability covariable had been controlled for, using an ANCOVA, it appeared that participants who faced difficulty during the first experiment improved during the second while the others did not. Significance. These studies suggest that (1) standard MI-BCI training protocols are suboptimal for skill teaching, (2) spatial ability is confirmed as impacting on MI-BCI performance, and (3) when faced

  3. Cross-Layer Active Predictive Congestion Control Protocol for Wireless Sensor Networks

    Directory of Open Access Journals (Sweden)

    Yinfeng Wu

    2009-10-01

    Full Text Available In wireless sensor networks (WSNs, there are numerous factors that may cause network congestion problems, such as the many-to-one communication modes, mutual interference of wireless links, dynamic changes of network topology and the memory-restrained characteristics of nodes. All these factors result in a network being more vulnerable to congestion. In this paper, a cross-layer active predictive congestion control scheme (CL-APCC for improving the performance of networks is proposed. Queuing theory is applied in the CL-APCC to analyze data flows of a single-node according to its memory status, combined with the analysis of the average occupied memory size of local networks. It also analyzes the current data change trends of local networks to forecast and actively adjust the sending rate of the node in the next period. In order to ensure the fairness and timeliness of the network, the IEEE 802.11 protocol is revised based on waiting time, the number of the node‟s neighbors and the original priority of data packets, which dynamically adjusts the sending priority of the node. The performance of CL-APCC, which is evaluated by extensive simulation experiments. is more efficient in solving the congestion in WSNs. Furthermore, it is clear that the proposed scheme has an outstanding advantage in terms of improving the fairness and lifetime of networks.

  4. Cross-layer active predictive congestion control protocol for wireless sensor networks.

    Science.gov (United States)

    Wan, Jiangwen; Xu, Xiaofeng; Feng, Renjian; Wu, Yinfeng

    2009-01-01

    In wireless sensor networks (WSNs), there are numerous factors that may cause network congestion problems, such as the many-to-one communication modes, mutual interference of wireless links, dynamic changes of network topology and the memory-restrained characteristics of nodes. All these factors result in a network being more vulnerable to congestion. In this paper, a cross-layer active predictive congestion control scheme (CL-APCC) for improving the performance of networks is proposed. Queuing theory is applied in the CL-APCC to analyze data flows of a single-node according to its memory status, combined with the analysis of the average occupied memory size of local networks. It also analyzes the current data change trends of local networks to forecast and actively adjust the sending rate of the node in the next period. In order to ensure the fairness and timeliness of the network, the IEEE 802.11 protocol is revised based on waiting time, the number of the node's neighbors and the original priority of data packets, which dynamically adjusts the sending priority of the node. The performance of CL-APCC, which is evaluated by extensive simulation experiments. is more efficient in solving the congestion in WSNs. Furthermore, it is clear that the proposed scheme has an outstanding advantage in terms of improving the fairness and lifetime of networks.

  5. Standardized terminology for clinical trial protocols based on top-level ontological categories.

    Science.gov (United States)

    Heller, B; Herre, H; Lippoldt, K; Loeffler, M

    2004-01-01

    This paper describes a new method for the ontologically based standardization of concepts with regard to the quality assurance of clinical trial protocols. We developed a data dictionary for medical and trial-specific terms in which concepts and relations are defined context-dependently. The data dictionary is provided to different medical research networks by means of the software tool Onto-Builder via the internet. The data dictionary is based on domain-specific ontologies and the top-level ontology of GOL. The concepts and relations described in the data dictionary are represented in natural language, semi-formally or formally according to their use.

  6. Difficulties in Controlling Mobilization Pain Using a Standardized Patient-Controlled Analgesia Protocol in Burns

    OpenAIRE

    Nilsson, Andreas; Kalman, Sigga; Arvidsson, Anders; Sjöberg, Folke

    2011-01-01

    The aim of this study was to evaluate pain relief for patients with burns during rest and mobilization with morphine according to a standard protocol for patient-controlled analgesia (PCA). Eighteen patients with a mean (SD) burned TBSA% of 26 (20) were studied for 10 days. Using a numeric rating scale (NRS, 0 = no pain and 10 = unbearable pain), patients were asked to estimate their acceptable and worst experienced pain by specifying a number on a scale and at what point they would like addi...

  7. Deficiency of Standard Effective-Medium Approximation for Ellipsometry of Layers of Nanoparticles

    Directory of Open Access Journals (Sweden)

    E. G. Bortchagovsky

    2015-01-01

    Full Text Available Correct description of optical properties of layers of disordered interacting nanoparticles is the problem. Contrary to volumes of nanocomposites, when standard models of effective-medium approximations (EMA work well, two-dimensional case of layers has intrinsic anisotropy, which influences interparticle interactions. The deficiency of standard Maxwell-Garnett model in the application to the ellipsometry of layers of gold nanoparticles is demonstrated. It demands the modification of EMA models and one way of this is considered in this paper. Contrary to existing 2D models with phenomenological parameters, the proposed Green function approach uses the same number of parameters as standard 3D EMA models for explicit calculations of effective parameters of layers of disordered nanoparticles.

  8. Energy Efficient Medium Access Control Protocol for Clustered Wireless Sensor Networks with Adaptive Cross-Layer Scheduling.

    Science.gov (United States)

    Sefuba, Maria; Walingo, Tom; Takawira, Fambirai

    2015-09-18

    This paper presents an Energy Efficient Medium Access Control (MAC) protocol for clustered wireless sensor networks that aims to improve energy efficiency and delay performance. The proposed protocol employs an adaptive cross-layer intra-cluster scheduling and an inter-cluster relay selection diversity. The scheduling is based on available data packets and remaining energy level of the source node (SN). This helps to minimize idle listening on nodes without data to transmit as well as reducing control packet overhead. The relay selection diversity is carried out between clusters, by the cluster head (CH), and the base station (BS). The diversity helps to improve network reliability and prolong the network lifetime. Relay selection is determined based on the communication distance, the remaining energy and the channel quality indicator (CQI) for the relay cluster head (RCH). An analytical framework for energy consumption and transmission delay for the proposed MAC protocol is presented in this work. The performance of the proposed MAC protocol is evaluated based on transmission delay, energy consumption, and network lifetime. The results obtained indicate that the proposed MAC protocol provides improved performance than traditional cluster based MAC protocols.

  9. South African Research Ethics Committee Review of Standards of Prevention in HIV Vaccine Trial Protocols.

    Science.gov (United States)

    Essack, Zaynab; Wassenaar, Douglas R

    2018-04-01

    HIV prevention trials provide a prevention package to participants to help prevent HIV acquisition. As new prevention methods are proven effective, this raises ethical and scientific design complexities regarding the prevention package or standard of prevention. Given its high HIV incidence and prevalence, South Africa has become a hub for HIV prevention research. For this reason, it is critical to study the implementation of relevant ethical-legal frameworks for such research in South Africa. This qualitative study used in-depth interviews to explore the practices and perspectives of eight members of South African research ethics committees (RECs) who have reviewed protocols for HIV vaccine trials. Their practices and perspectives are compared with ethics guideline requirements for standards of prevention.

  10. Standard Operational Protocols in professional nursing practice: use, weaknesses and potentialities.

    Science.gov (United States)

    Sales, Camila Balsero; Bernardes, Andrea; Gabriel, Carmen Silvia; Brito, Maria de Fátima Paiva; Moura, André Almeida de; Zanetti, Ariane Cristina Barboza

    2018-01-01

    to evaluate the use of Standard Operational Protocols (SOPs) in the professional practice of the nursing team based on the theoretical framework of Donabedian, as well as to identify the weaknesses and potentialities from its implementation. Evaluative research, with quantitative approach performed with nursing professionals working in the Health Units of a city of São Paulo, composed of two stages: document analysis and subsequent application of a questionnaire to nursing professionals. A total of 247 nursing professionals participated and reported changes in the way the interventions were performed. The main weaknesses were the small number of professionals, inadequate physical structure and lack of materials. Among the potentialities were: the standardization of materials and concern of the manager and professional related to patient safety. The reassessment of SOPs is necessary, as well as the adoption of a strategy of permanent education of professionals aiming at improving the quality of care provided.

  11. Standard Operational Protocols in professional nursing practice: use, weaknesses and potentialities

    Directory of Open Access Journals (Sweden)

    Camila Balsero Sales

    Full Text Available ABSTRACT Objective: to evaluate the use of Standard Operational Protocols (SOPs in the professional practice of the nursing team based on the theoretical framework of Donabedian, as well as to identify the weaknesses and potentialities from its implementation. Method: Evaluative research, with quantitative approach performed with nursing professionals working in the Health Units of a city of São Paulo, composed of two stages: document analysis and subsequent application of a questionnaire to nursing professionals. Results: A total of 247 nursing professionals participated and reported changes in the way the interventions were performed. The main weaknesses were the small number of professionals, inadequate physical structure and lack of materials. Among the potentialities were: the standardization of materials and concern of the manager and professional related to patient safety. Conclusion: The reassessment of SOPs is necessary, as well as the adoption of a strategy of permanent education of professionals aiming at improving the quality of care provided.

  12. Multiparametric multidetector computed tomography scanning on suspicion of hyperacute ischemic stroke: validating a standardized protocol

    Directory of Open Access Journals (Sweden)

    Felipe Torres Pacheco

    2013-06-01

    Full Text Available Multidetector computed tomography (MDCT scanning has enabled the early diagnosis of hyperacute brain ischemia. We aimed at validating a standardized protocol to read and report MDCT techniques in a series of adult patients. The inter-observer agreement among the trained examiners was tested, and their results were compared with a standard reading. No false positives were observed, and an almost perfect agreement (Kappa>0.81 was documented when the CT angiography (CTA and cerebral perfusion CT (CPCT map data were added to the noncontrast CT (NCCT analysis. The inter-observer agreement was higher for highly trained readers, corroborating the need for specific training to interpret these modern techniques. The authors recommend adding CTA and CPCT to the NCCT analysis in order to clarify the global analysis of structural and hemodynamic brain abnormalities. Our structured report is suitable as a script for the reproducible analysis of the MDCT of patients on suspicion of ischemic stroke.

  13. Standardized communication protocol for BAS (IEIEJ/p); BAS hyojun interface shiyo (IEIEJ/p)

    Energy Technology Data Exchange (ETDEWEB)

    Toyoda, T. [Hitachi Building System Co. Ltd., Tokyo (Japan)

    2000-10-05

    For the BEMS user, to construct his BEMS tinder the multiple vendors environment is very beneficial because he could choice the most appropriate vendor among many vendors about every subsystem for the view point of technique and cost at any time. The effective tool which makes the BEMS tinder the multiple environment possible is the BACnet protocol which had developed and been standardized by ANSI/ASHRAE of U.S.. Institute of Electrical Installation Engineers-of Japan (IEIEJ) offers IEIEJ/p based on BACnet as IEIEJ's standard which is added the function of autonomous decentralized control to enhance the BEMS reliability to fit the Japanese multiple vendors environment, In this paper I present the outline of it's specification and feature of IEIEJ/p. (author)

  14. Cross-layer cluster-based energy-efficient protocol for wireless sensor networks.

    Science.gov (United States)

    Mammu, Aboobeker Sidhik Koyamparambil; Hernandez-Jayo, Unai; Sainz, Nekane; de la Iglesia, Idoia

    2015-04-09

    Recent developments in electronics and wireless communications have enabled the improvement of low-power and low-cost wireless sensors networks (WSNs). One of the most important challenges in WSNs is to increase the network lifetime due to the limited energy capacity of the network nodes. Another major challenge in WSNs is the hot spots that emerge as locations under heavy traffic load. Nodes in such areas quickly drain energy resources, leading to disconnection in network services. In such an environment, cross-layer cluster-based energy-efficient algorithms (CCBE) can prolong the network lifetime and energy efficiency. CCBE is based on clustering the nodes to different hexagonal structures. A hexagonal cluster consists of cluster members (CMs) and a cluster head (CH). The CHs are selected from the CMs based on nodes near the optimal CH distance and the residual energy of the nodes. Additionally, the optimal CH distance that links to optimal energy consumption is derived. To balance the energy consumption and the traffic load in the network, the CHs are rotated among all CMs. In WSNs, energy is mostly consumed during transmission and reception. Transmission collisions can further decrease the energy efficiency. These collisions can be avoided by using a contention-free protocol during the transmission period. Additionally, the CH allocates slots to the CMs based on their residual energy to increase sleep time. Furthermore, the energy consumption of CH can be further reduced by data aggregation. In this paper, we propose a data aggregation level based on the residual energy of CH and a cost-aware decision scheme for the fusion of data. Performance results show that the CCBE scheme performs better in terms of network lifetime, energy consumption and throughput compared to low-energy adaptive clustering hierarchy (LEACH) and hybrid energy-efficient distributed clustering (HEED).

  15. Protocol for characterization of clay as a backfill and coverage layers for surface repository

    International Nuclear Information System (INIS)

    Santos, Daisy M.M.; Tello, Clédola C.O.

    2017-01-01

    The Radioactive Waste Management includes the operations since generation of the waste until its storage in repository, ensuring the protection of human beings and the environment from the possible negative impacts. The radioactive waste is segregated, treated, conditioned in suitable packages for posterior storage or disposal in repository. The 'RBMN Project' objective is to implement the repository for the disposal of low and intermediate level radioactive wastes generated by nuclear activities in Brazil, proposing a definitive solution for their storage. Engineered and natural barriers as the backfill and coverage layers will compose the disposal system of a near surface repository, concept proposed by the 'RBMN Project'. The use of these barriers aims to avoid or restrict the release of radionuclides from the waste to the human beings and environment. The waterproofing barriers are composed of clays. Certainly, for the national repository, will be used those clays existing in the place where it will be constructed. Them some basic tests will have to be carried out to verify the suitability of these clays as barriers. These tests were determined and performed with reference clay, a Brazilian bentonite constituted of 67.2% montmorillonite. The results were compared with national and international literature of materials with similar mineralogical features. The values found with 95% of confidence interval were 9.73±0,35 μm for granulometric size; 13,3±0,6% for the moisture content and 816±9 mmol.kg -1 for the capacity of cationic exchange. A protocol for characterization of clay was elaborated presenting these tests for it future use. (author)

  16. Protocol for characterization of clay as a backfill and coverage layers for surface repository

    Energy Technology Data Exchange (ETDEWEB)

    Santos, Daisy M.M.; Tello, Clédola C.O., E-mail: marymarchezini@gmail.com, E-mail: tellocc@cdtn.br [Centro de Desenvolvimento da Tecnologia Nuclear (CDTN/CNEN-MG), Belo Horizonte, MG (Brazil)

    2017-07-01

    The Radioactive Waste Management includes the operations since generation of the waste until its storage in repository, ensuring the protection of human beings and the environment from the possible negative impacts. The radioactive waste is segregated, treated, conditioned in suitable packages for posterior storage or disposal in repository. The 'RBMN Project' objective is to implement the repository for the disposal of low and intermediate level radioactive wastes generated by nuclear activities in Brazil, proposing a definitive solution for their storage. Engineered and natural barriers as the backfill and coverage layers will compose the disposal system of a near surface repository, concept proposed by the 'RBMN Project'. The use of these barriers aims to avoid or restrict the release of radionuclides from the waste to the human beings and environment. The waterproofing barriers are composed of clays. Certainly, for the national repository, will be used those clays existing in the place where it will be constructed. Them some basic tests will have to be carried out to verify the suitability of these clays as barriers. These tests were determined and performed with reference clay, a Brazilian bentonite constituted of 67.2% montmorillonite. The results were compared with national and international literature of materials with similar mineralogical features. The values found with 95% of confidence interval were 9.73±0,35 μm for granulometric size; 13,3±0,6% for the moisture content and 816±9 mmol.kg{sup -1} for the capacity of cationic exchange. A protocol for characterization of clay was elaborated presenting these tests for it future use. (author)

  17. Cross-Layer Cluster-Based Energy-Efficient Protocol for Wireless Sensor Networks

    Directory of Open Access Journals (Sweden)

    Aboobeker Sidhik Koyamparambil Mammu

    2015-04-01

    Full Text Available Recent developments in electronics and wireless communications have enabled the improvement of low-power and low-cost wireless sensors networks (WSNs. One of the most important challenges in WSNs is to increase the network lifetime due to the limited energy capacity of the network nodes. Another major challenge in WSNs is the hot spots that emerge as locations under heavy traffic load. Nodes in such areas quickly drain energy resources, leading to disconnection in network services. In such an environment, cross-layer cluster-based energy-efficient algorithms (CCBE can prolong the network lifetime and energy efficiency. CCBE is based on clustering the nodes to different hexagonal structures. A hexagonal cluster consists of cluster members (CMs and a cluster head (CH. The CHs are selected from the CMs based on nodes near the optimal CH distance and the residual energy of the nodes. Additionally, the optimal CH distance that links to optimal energy consumption is derived. To balance the energy consumption and the traffic load in the network, the CHs are rotated among all CMs. In WSNs, energy is mostly consumed during transmission and reception. Transmission collisions can further decrease the energy efficiency. These collisions can be avoided by using a contention-free protocol during the transmission period. Additionally, the CH allocates slots to the CMs based on their residual energy to increase sleep time. Furthermore, the energy consumption of CH can be further reduced by data aggregation. In this paper, we propose a data aggregation level based on the residual energy of CH and a cost-aware decision scheme for the fusion of data. Performance results show that the CCBE scheme performs better in terms of network lifetime, energy consumption and throughput compared to low-energy adaptive clustering hierarchy (LEACH and hybrid energy-efficient distributed clustering (HEED.

  18. Latency-Optimized and Energy-Efficient MAC Protocol for Underwater Acoustic Sensor Networks: A Cross-Layer Approach

    Directory of Open Access Journals (Sweden)

    Cheng Xiuzhen

    2010-01-01

    Full Text Available Considering the energy constraint for fixed sensor nodes and the unacceptable long propagation delay, especially for latency sensitive applications of underwater acoustic sensor networks, we propose a MAC protocol that is latency-optimized and energy-efficient scheme and combines the physical layer and the MAC layer to shorten transmission delay. On physical layer, we apply convolution coding and interleaver for transmitted information. Moreover, dynamic code rate is exploited at the receiver side to accelerate data reception rate. On MAC layer, unfixed frame length scheme is applied to reduce transmission delay, and to ensure the data successful transmission rate at the same time. Furthermore, we propose a network topology: an underwater acoustic sensor network with mobile agent. Through fully utilizing the supper capabilities on computation and mobility of autonomous underwater vehicles, the energy consumption for fixed sensor nodes can be extremely reduced, so that the lifetime of networks is extended.

  19. Difficulties in controlling mobilization pain using a standardized patient-controlled analgesia protocol in burns.

    Science.gov (United States)

    Nilsson, Andreas; Kalman, Sigga; Sonesson, Lena Karin; Arvidsson, Anders; Sjöberg, Folke

    2011-01-01

    The aim of this study was to evaluate pain relief for patients with burns during rest and mobilization with morphine according to a standard protocol for patient-controlled analgesia (PCA). Eighteen patients with a mean (SD) burned TBSA% of 26 (20) were studied for 10 days. Using a numeric rating scale (NRS, 0 = no pain and 10 = unbearable pain), patients were asked to estimate their acceptable and worst experienced pain by specifying a number on a scale and at what point they would like additional analgesics. Patients were allowed free access to morphine with a PCA pump device. Bolus doses were set according to age, (100 - age)/24 = bolus dose (mg), and 6 minutes lockout time. Degrees of pain, morphine requirements, doses delivered and demanded, oral intake of food, and antiemetics given were used as endpoints. Acceptable pain (mean [SD]) was estimated to be 3.8 (1.3) on the NRS, and additional treatment was considered necessary at scores of 4.3 (1.6) or more. NRS at rest was 2.7 (2.2) and during mobilization 4.7 (2.6). Required mean morphine per day was 81 (15) mg, and the number of doses requested increased during the first 6 days after the burn. The authors found no correlation between dose of morphine required and any other variables. Background pain can be controlled adequately with a standard PCA protocol. During mobilization, the pain experienced was too intense, despite having the already high doses of morphine increased. The present protocol must be refined further to provide analgesia adequate to cover mobilization as well.

  20. A Standardized Shift Handover Protocol: Improving Nurses’ Safe Practice in Intensive Care Units

    Directory of Open Access Journals (Sweden)

    Javad Malekzadeh

    2013-08-01

    Full Text Available Introduction: For maintaining the continuity of care and improving the quality of care, effective inter-shift information communication is necessary. Any handover error can endanger patient safety. Despite the importance of shift handover, there is no standard handover protocol in our healthcare settings. Methods In this one-group pretest-posttest quasi-experimental study conducted in spring and summer of 2011, we recruited a convenience sample of 56 ICU nurses. The Nurses’ Safe Practice Evaluation Checklist was used for data collection. The Content Validity Index and the inter-rater correlation coefficient of the checklist was 0.92 and 89, respectively. We employed the SPSS 11.5 software and the Mc Nemar and paired-samples t test for data analysis. Results: Study findings revealed that nurses’ mean score on the Safe Practice Evaluation Checklist increased significantly from 11.6 (2.7 to 17.0 (1.8 (P < 0.001. Conclusion: using a standard handover protocol for communicating patient’s needs and information improves nurses’ safe practice in the area of basic nursing care.

  1. Outcomes of Optimized over Standard Protocol of Rabbit Antithymocyte Globulin for Severe Aplastic Anemia: A Single-Center Experience

    Science.gov (United States)

    Ge, Meili; Shao, Yingqi; Huang, Jinbo; Huang, Zhendong; Zhang, Jing; Nie, Neng; Zheng, Yizhou

    2013-01-01

    Background Previous reports showed that outcome of rabbit antithymocyte globulin (rATG) was not satisfactory as the first-line therapy for severe aplastic anemia (SAA). We explored a modifying schedule of administration of rATG. Design and Methods Outcomes of a cohort of 175 SAA patients, including 51 patients administered with standard protocol (3.55 mg/kg/d for 5 days) and 124 cases with optimized protocol (1.97 mg/kg/d for 9 days) of rATG plus cyclosporine (CSA), were analyzed retrospectively. Results Of all 175 patients, response rates at 3 and 6 months were 36.6% and 56.0%, respectively. 51 cases received standard protocol had poor responses at 3 (25.5%) and 6 months (41.2%). However, 124 patients received optimized protocol had better responses at 3 (41.1%, P = 0.14) and 6 (62.1%, P = 0.01). Higher incidences of infection (57.1% versus 37.9%, P = 0.02) and early mortality (17.9% versus 0.8%, P<0.001) occurred in patients received standard protocol compared with optimized protocol. The 5-year overall survival in favor of the optimized over standard rATG protocol (76.0% versus. 50.3%, P<0.001) was observed. By multivariate analysis, optimized protocol (RR = 2.21, P = 0.04), response at 3 months (RR = 10.31, P = 0.03) and shorter interval (<23 days) between diagnosis and initial dose of rATG (RR = 5.35, P = 0.002) were independent favorable predictors of overall survival. Conclusions Optimized instead of standard rATG protocol in combination with CSA remained efficacious as a first-line immunosuppressive regimen for SAA. PMID:23554855

  2. Telemetry Standards, RCC Standard 106-17, Chapter 27, RF Network Access Layer

    Science.gov (United States)

    2017-07-01

    to the physical media (i.e., the wireless RF network). On the transmission side, it is responsible for framing IP packets for physical transmission ...resolution bandwidth of 30 kHz. It was measured during the steady power condition during a burst transmission . Telemetry Standards, RCC Standard... power levels available for modulated burst transmission . Table 27-1. Transceiver Phase Noise Mask dBc/Hz Frequency Offset −30 dBc/Hz 10 Hz −60 dBc

  3. Effect of a Standardized Protocol of Antibiotic Therapy on Surgical Site Infection after Laparoscopic Surgery for Complicated Appendicitis.

    Science.gov (United States)

    Park, Hyoung-Chul; Kim, Min Jeong; Lee, Bong Hwa

    Although it is accepted that complicated appendicitis requires antibiotic therapy to prevent post-operative surgical infections, consensus protocols on the duration and regimens of treatment are not well established. This study aimed to compare the outcome of post-operative infectious complications in patients receiving old non-standardized and new standard antibiotic protocols, involving either 5 or 10 days of treatment, respectively. We enrolled 1,343 patients who underwent laparoscopic surgery for complicated appendicitis between January 2009 and December 2014. At the beginning of the new protocol, the patients were divided into two groups; 10 days of various antibiotic regimens (between January 2009 and June 2012, called the non-standardized protocol; n = 730) and five days of cefuroxime and metronidazole regimen (between July 2012 and December 2014; standardized protocol; n = 613). We compared the clinical outcomes, including surgical site infection (SSI) (superficial and deep organ/space infections) in the two groups. The standardized protocol group had a slightly shorter operative time (67 vs. 69 min), a shorter hospital stay (5 vs. 5.4 d), and lower medical cost (US$1,564 vs. US$1,654). Otherwise, there was no difference between the groups. No differences were found in the non-standardized and standard protocol groups with regard to the rate of superficial infection (10.3% vs. 12.7%; p = 0.488) or deep organ/space infection (2.3% vs. 2.1%; p = 0.797). In patients undergoing laparoscopic surgery for complicated appendicitis, five days of cefuroxime and metronidazole did not lead to more SSIs, and it decreased the medical costs compared with non-standardized antibiotic regimens.

  4. Improving biofeedback for the treatment of fecal incontinence in women: implementation of a standardized multi-site manometric biofeedback protocol.

    Science.gov (United States)

    Markland, A D; Jelovsek, J E; Whitehead, W E; Newman, D K; Andy, U U; Dyer, K; Harm-Ernandes, I; Cichowski, S; McCormick, J; Rardin, C; Sutkin, G; Shaffer, A; Meikle, S

    2017-01-01

    Standardized training and clinical protocols using biofeedback for the treatment of fecal incontinence (FI) are important for clinical care. Our primary aims were to develop, implement, and evaluate adherence to a standardized protocol for manometric biofeedback to treat FI. In a Pelvic Floor Disorders Network (PFDN) trial, participants were enrolled from eight PFDN clinical centers across the United States. A team of clinical and equipment experts developed biofeedback software on a novel tablet computer platform for conducting standardized anorectal manometry with separate manometric biofeedback protocols for improving anorectal muscle strength, sensation, and urge resistance. The training protocol also included education on bowel function, anal sphincter exercises, and bowel diary monitoring. Study interventionists completed online training prior to attending a centralized, standardized certification course. For the certification, expert trainers assessed the ability of the interventionists to perform the protocol components for a paid volunteer who acted as a standardized patient. Postcertification, the trainers audited interventionists during trial implementation to improve protocol adherence. Twenty-four interventionists attended the in-person training and certification, including 46% advanced practice registered nurses (11/24), 50% (12/24) physical therapists, and 4% physician assistants (1/24). Trainers performed audio audits for 88% (21/24), representing 84 audited visits. All certified interventionists met or exceeded the prespecified 80% pass rate for the audit process, with an average passing rate of 93%. A biofeedback protocol can be successfully imparted to experienced pelvic floor health care providers from various disciplines. Our process promoted high adherence to a standard protocol and is applicable to many clinical settings. © 2016 John Wiley & Sons Ltd.

  5. Comparison of a fast 5-min knee MRI protocol with a standard knee MRI protocol. A multi-institutional multi-reader study

    Energy Technology Data Exchange (ETDEWEB)

    FitzGerald Alaia, Erin; Beltran, Luis S.; Garwood, Elisabeth; Burke, Christopher J.; Gyftopoulos, Soterios [NYU Langone Medical Center, Department of Radiology, Musculoskeletal Division, New York, NY (United States); Benedick, Alex [Case Western Reserve University, School of Medicine, Cleveland, OH (United States); Obuchowski, Nancy A. [Cleveland Clinic, Department of Quantitative Health Sciences, Cleveland, OH (United States); Polster, Joshua M.; Schils, Jean; Subhas, Naveen [Cleveland Clinic, Department of Radiology, Musculoskeletal Division, Cleveland, OH (United States); Chang, I. Yuan Joseph [Texas Scottish Rite Hospital for Children, Dallas, TX (United States)

    2018-01-15

    To compare diagnostic performance of a 5-min knee MRI protocol to that of a standard knee MRI. One hundred 3 T (100 patients, mean 38.8 years) and 50 1.5 T (46 patients, mean 46.4 years) MRIs, consisting of 5 fast, 2D multi-planar fast-spin-echo (FSE) sequences and five standard multiplanar FSE sequences, from two academic centers (1/2015-1/2016), were retrospectively reviewed by four musculoskeletal radiologists. Agreement between fast and standard (interprotocol agreement) and between standard (intraprotocol agreement) readings for meniscal, ligamentous, chondral, and bone pathology was compared for interchangeability. Frequency of major findings, sensitivity, and specificity was also tested for each protocol. Interprotocol agreement using fast MRI was similar to intraprotocol agreement with standard MRI (83.0-99.5%), with no excess disagreement (≤ 1.2; 95% CI, -4.2 to 3.8%), across all structures. Frequency of major findings (1.1-22.4% across structures) on fast and standard MRI was not significantly different (p ≥ 0.215), except more ACL tears on fast MRI (p = 0.021) and more cartilage defects on standard MRI (p < 0.001). Sensitivities (59-100%) and specificities (73-99%) of fast and standard MRI were not significantly different for meniscal and ligament tears (95% CI for difference, -0.08-0.08). For cartilage defects, fast MRI was slightly less sensitive (95% CI for difference, -0.125 to -0.01) but slightly more specific (95% CI for difference, 0.01-0.5) than standard MRI. A fast 5-min MRI protocol is interchangeable with and has similar accuracy to a standard knee MRI for evaluating internal derangement of the knee. (orig.)

  6. Comparison of a fast 5-min knee MRI protocol with a standard knee MRI protocol. A multi-institutional multi-reader study

    International Nuclear Information System (INIS)

    FitzGerald Alaia, Erin; Beltran, Luis S.; Garwood, Elisabeth; Burke, Christopher J.; Gyftopoulos, Soterios; Benedick, Alex; Obuchowski, Nancy A.; Polster, Joshua M.; Schils, Jean; Subhas, Naveen; Chang, I. Yuan Joseph

    2018-01-01

    To compare diagnostic performance of a 5-min knee MRI protocol to that of a standard knee MRI. One hundred 3 T (100 patients, mean 38.8 years) and 50 1.5 T (46 patients, mean 46.4 years) MRIs, consisting of 5 fast, 2D multi-planar fast-spin-echo (FSE) sequences and five standard multiplanar FSE sequences, from two academic centers (1/2015-1/2016), were retrospectively reviewed by four musculoskeletal radiologists. Agreement between fast and standard (interprotocol agreement) and between standard (intraprotocol agreement) readings for meniscal, ligamentous, chondral, and bone pathology was compared for interchangeability. Frequency of major findings, sensitivity, and specificity was also tested for each protocol. Interprotocol agreement using fast MRI was similar to intraprotocol agreement with standard MRI (83.0-99.5%), with no excess disagreement (≤ 1.2; 95% CI, -4.2 to 3.8%), across all structures. Frequency of major findings (1.1-22.4% across structures) on fast and standard MRI was not significantly different (p ≥ 0.215), except more ACL tears on fast MRI (p = 0.021) and more cartilage defects on standard MRI (p < 0.001). Sensitivities (59-100%) and specificities (73-99%) of fast and standard MRI were not significantly different for meniscal and ligament tears (95% CI for difference, -0.08-0.08). For cartilage defects, fast MRI was slightly less sensitive (95% CI for difference, -0.125 to -0.01) but slightly more specific (95% CI for difference, 0.01-0.5) than standard MRI. A fast 5-min MRI protocol is interchangeable with and has similar accuracy to a standard knee MRI for evaluating internal derangement of the knee. (orig.)

  7. The effect of a standardized protocol for iron supplementation to blood donors low in hemoglobin concentration.

    Science.gov (United States)

    Magnussen, Karin; Bork, Nanna; Asmussen, Lisa

    2008-04-01

    Iron deficiency leading to low hemoglobin concentration (cHb) is a common problem for blood donors as well as for blood banks. A standardized protocol offering iron supplementation based on P-ferritin determination may help to reduce the problem and retain donors. This was a prospective study where 879 blood donors, presenting with cHb at or below the limit of acceptance for donation, were included. The predonation cHb result was read after donation. The donors received 50 iron tablets (JernC or Ferrochel, 100 or 25 mg elemental iron, respectively), and samples for P-ferritin, mean corpuscular volume, and control of cHb were secured. Based on a P-ferritin level of less than 60 microg per L, 20 iron tablets were offered after all following donations. Mean cHb was 7.6 mmol per L (122 g/L) and 8.2 mmol per L (132 g/L) in women and men, respectively. In 80 percent of the women and 48 percent of the men, iron stores were low (P-ferritin protocol offering iron supplementation and simple oral and written advice based on P-ferritin measurements is effective in normalizing cHb and retaining donors presenting with cHb at or below the limit of acceptance for donation.

  8. Age and gender leucocytes variances and references values generated using the standardized ONE-Study protocol

    DEFF Research Database (Denmark)

    Kverneland, Anders H.; Streitz, Mathias; Geissler, Edward

    2016-01-01

    blood flow cytometry. The performance of our protocols was challenged here by profiling samples from healthy volunteers to reveal age- and gender-dependent differences and to establish a standardized reference cohort for use in clinical trials. Whole blood samples from two different cohorts were...... analyzed (first cohort: n = 52, second cohort: n = 46, both 20–84 years with equal gender distribution). The second cohort was run as a validation cohort by a different operator. The “ONE Study” panels were applied to analyze expression of >30 different surface markers to enumerate proportional...... cohort. Thus, we have proven the utility of our strategy and generated reproducible reference ranges accounting for age- and gender-dependent differences, which are crucial for a better patient monitoring and individualized therapy....

  9. Impact of a standardized nurse observation protocol including MEWS after Intensive Care Unit discharge.

    Science.gov (United States)

    De Meester, K; Das, T; Hellemans, K; Verbrugghe, W; Jorens, P G; Verpooten, G A; Van Bogaert, P

    2013-02-01

    Analysis of in-hospital mortality after serious adverse events (SAE's) in our hospital showed the need for more frequent observation in medical and surgical wards. We hypothesized that the incidence of SAE's could be decreased by introducing a standard nurse observation protocol. To investigate the effect of a standard nurse observation protocol implementing the Modified Early Warning Score (MEWS) and a color graphic observation chart. Pre- and post-intervention study by analysis of patients records for a 5-day period after Intensive Care Unit (ICU) discharge to 14 medical and surgical wards before (n=530) and after (n=509) the intervention. For the total study population the mean Patient Observation Frequency Per Nursing Shift (POFPNS) during the 5-day period after ICU discharge increased from .9993 (95% C.I. .9637-1.0350) in the pre-intervention period to 1.0732 (95% C.I. 1.0362-1.1101) (p=.005) in the post-intervention period. There was an increased risk of a SAE in patients with MEWS 4 or higher in the present nursing shift (HR 8.25; 95% C.I. 2.88-23.62) and the previous nursing shift (HR 12.83;95% C.I. 4.45-36.99). There was an absolute risk reduction for SAE's within 120h after ICU discharge of 2.2% (95% C.I. -0.4-4.67%) from 5.7% to 3.5%. The intervention had a positive impact on the observation frequency. MEWS had a predictive value for SAE's in patients after ICU discharge. The drop in SAE's was substantial but did not reach statistical significance. Copyright © 2012 Elsevier Ireland Ltd. All rights reserved.

  10. Comparing Short Dental Implants to Standard Dental Implants: Protocol for a Systematic Review.

    Science.gov (United States)

    Rokn, Amir Reza; Keshtkar, Abbasali; Monzavi, Abbas; Hashemi, Kazem; Bitaraf, Tahereh

    2018-01-18

    Short dental implants have been proposed as a simpler, cheaper, and faster alternative for the rehabilitation of atrophic edentulous areas to avoid the disadvantages of surgical techniques for increasing bone volume. This review will compare short implants (4 to 8 mm) to standard implants (larger than 8 mm) in edentulous jaws, evaluating on the basis of marginal bone loss (MBL), survival rate, complications, and prosthesis failure. We will electronically search for randomized controlled trials comparing short dental implants to standard dental implants in the following databases: PubMed, Web of Science, EMBASE, Scopus, the Cochrane Central Register of Controlled Trials, and ClinicalTrials.gov with English language restrictions. We will manually search the reference lists of relevant reviews and the included articles in this review. The following journals will also be searched: European Journal of Oral Implantology, Clinical Oral Implants Research, and Clinical Implant Dentistry and Related Research. Two reviewers will independently perform the study selection, data extraction and quality assessment (using the Cochrane Collaboration tool) of included studies. All meta-analysis procedures including appropriate effect size combination, sub-group analysis, meta-regression, assessing publication or reporting bias will be performed using Stata (Statacorp, TEXAS) version 12.1. Short implant effectiveness will be assessed using the mean difference of MBL in terms of weighted mean difference (WMD) and standardized mean difference (SMD) using Cohen's method. The combined effect size measures in addition to the related 95% confidence intervals will be estimated by a fixed effect model. The heterogeneity of the related effect size will be assessed using a Q Cochrane test and I2 measure. The MBL will be presented by a standardized mean difference with a 95% confidence interval. The survival rate of implants, prostheses failures, and complications will be reported using a risk

  11. Standardizing serum 25-hydroxyvitamin D data from four Nordic population samples using the Vitamin D Standardization Program protocols: Shedding new light on vitamin D status in Nordic individuals

    DEFF Research Database (Denmark)

    Cashman, Kevin D; Dowling, Kirsten G; Škrabáková, Zuzana

    2015-01-01

    for the European Union are of variable quality making it difficult to estimate the prevalence of vitamin D deficiency across member states. As a consequence of the widespread, method-related differences in measurements of serum 25(OH)D concentrations, the Vitamin D Standardization Program (VDSP) developed...... protocols for standardizing existing serum 25(OH)D data from national surveys around the world. The objective of the present work was to apply the VDSP protocols to existing serum 25(OH)D data from a Danish, a Norwegian, and a Finnish population-based health survey and from a Danish randomized controlled...

  12. Satellite Communications Using Commercial Protocols

    Science.gov (United States)

    Ivancic, William D.; Griner, James H.; Dimond, Robert; Frantz, Brian D.; Kachmar, Brian; Shell, Dan

    2000-01-01

    NASA Glenn Research Center has been working with industry, academia, and other government agencies in assessing commercial communications protocols for satellite and space-based applications. In addition, NASA Glenn has been developing and advocating new satellite-friendly modifications to existing communications protocol standards. This paper summarizes recent research into the applicability of various commercial standard protocols for use over satellite and space- based communications networks as well as expectations for future protocol development. It serves as a reference point from which the detailed work can be readily accessed. Areas that will be addressed include asynchronous-transfer-mode quality of service; completed and ongoing work of the Internet Engineering Task Force; data-link-layer protocol development for unidirectional link routing; and protocols for aeronautical applications, including mobile Internet protocol routing for wireless/mobile hosts and the aeronautical telecommunications network protocol.

  13. Anthropometric protocols for the construction of new international fetal and newborn growth standards: the INTERGROWTH-21st Project.

    Science.gov (United States)

    Cheikh Ismail, L; Knight, H E; Bhutta, Z; Chumlea, W C

    2013-09-01

    The primary aim of the INTERGROWTH-21(st) Project is to construct new, prescriptive standards describing optimal fetal and preterm postnatal growth. The anthropometric measurements include the head circumference, recumbent length and weight of the infants, and the stature and weight of the parents. In such a large, international, multicentre project, it is critical that all study sites follow standardised protocols to ensure maximal validity of the growth and nutrition indicators used. This paper describes, in detail, the selection of anthropometric personnel, equipment, and measurement and calibration protocols used to construct the new standards. Implementing these protocols at each study site ensures that the anthropometric data are of the highest quality to construct the international standards. © 2013 Royal College of Obstetricians and Gynaecologists.

  14. Methodological Study to Develop Standard Operational Protocol on Oral Drug Administration for Children.

    Science.gov (United States)

    Bijarania, Sunil Kumar; Saini, Sushma Kumari; Verma, Sanjay; Kaur, Sukhwinder

    2017-05-01

    To develop standard operational protocol (SOP) on oral drug administration and checklist to assess the implementation of the developed SOP. In this prospective methodological study, SOPs were developed in five phases. In the first phase, the preliminary draft of SOPs and checklists were prepared based on literature review, assessment of current practices and focus group discussion (FGD) with bedside working nurses. In the second phase, content validity was checked with the help of Delphi technique (12 experts). Total four drafts were prepared in stages and necessary modifications were made as per suggestions after each Delphi round. Fourth Delphi round was performed after conducting a pilot study. In the fourth phase, all bedside nurses were trained as per SOPs and asked to practice accordingly and observation of thirty oral drug administrations in children was done to check reliability of checklists for implementation of SOPs. In Phase-V, 7 FGDs were conducted with bedside nurses to assess the effectiveness of SOPs. The Content Validity Index (CVI) of SOP and checklists was 99.77%. Overall standardized Cronbach's alpha was calculated as 0.94. All the nurses felt that the SOP is useful. Valid and feasible SOP for drug administration to children through oral route along with valid and reliable checklist were developed. It is recommended to use this document for drug administration to children.

  15. Standardization and Optimization of Computed Tomography Protocols to Achieve Low-Dose

    Science.gov (United States)

    Chin, Cynthia; Cody, Dianna D.; Gupta, Rajiv; Hess, Christopher P.; Kalra, Mannudeep K.; Kofler, James M.; Krishnam, Mayil S.; Einstein, Andrew J.

    2014-01-01

    The increase in radiation exposure due to CT scans has been of growing concern in recent years. CT scanners differ in their capabilities and various indications require unique protocols, but there remains room for standardization and optimization. In this paper we summarize approaches to reduce dose, as discussed in lectures comprising the first session of the 2013 UCSF Virtual Symposium on Radiation Safety in Computed Tomography. The experience of scanning at low dose in different body regions, for both diagnostic and interventional CT procedures, is addressed. An essential primary step is justifying the medical need for each scan. General guiding principles for reducing dose include tailoring a scan to a patient, minimizing scan length, use of tube current modulation and minimizing tube current, minimizing-tube potential, iterative reconstruction, and periodic review of CT studies. Organized efforts for standardization have been spearheaded by professional societies such as the American Association of Physicists in Medicine. Finally, all team members should demonstrate an awareness of the importance of minimizing dose. PMID:24589403

  16. Is a New Protocol for Acute Lymphoblastic Leukemia Research or Standard Therapy?

    NARCIS (Netherlands)

    Dekking, SAS; van der Graaf, R; de Vries, Martine; Bierings, MB; van Delden, JJM; Kodish, Eric; Lantos, John

    2015-01-01

    In the United States, doctors generally develop new cancer chemotherapy for children by testing innovative chemotherapy protocols against existing protocols in prospective randomized trials. In the Netherlands, children with leukemia are treated by protocols that are agreed upon by the Dutch

  17. MAC-layer protocol for TCP fairness in Wireless Mesh Networks

    KAUST Repository

    Nawab, Faisal

    2012-08-01

    In this paper we study the interactions of TCP and IEEE 802.11 MAC in Wireless Mesh Networks (WMNs). We use a Markov chain to capture the behavior of TCP sessions, particularly the impact on network throughput performance due to the effect of queue utilization and packet relaying. A closed form solution is derived to numerically determine the throughput. Based on the developed model, we propose a distributed MAC protocol to alleviate the unfairness problem in WMNs. Our protocol uses the age of packet as a priority metric for packet scheduling. Simulation is conducted to validate our model and to illustrate the fairness characteristics of our proposed MAC protocol. We conclude that we can achieve fairness with only little impact on network capacity.

  18. Protocol of the COSMIN study: COnsensus-based Standards for the selection of health Measurement INstruments

    Directory of Open Access Journals (Sweden)

    Patrick DL

    2006-01-01

    Full Text Available Abstract Background Choosing an adequate measurement instrument depends on the proposed use of the instrument, the concept to be measured, the measurement properties (e.g. internal consistency, reproducibility, content and construct validity, responsiveness, and interpretability, the requirements, the burden for subjects, and costs of the available instruments. As far as measurement properties are concerned, there are no sufficiently specific standards for the evaluation of measurement properties of instruments to measure health status, and also no explicit criteria for what constitutes good measurement properties. In this paper we describe the protocol for the COSMIN study, the objective of which is to develop a checklist that contains COnsensus-based Standards for the selection of health Measurement INstruments, including explicit criteria for satisfying these standards. We will focus on evaluative health related patient-reported outcomes (HR-PROs, i.e. patient-reported health measurement instruments used in a longitudinal design as an outcome measure, excluding health care related PROs, such as satisfaction with care or adherence. The COSMIN standards will be made available in the form of an easily applicable checklist. Method An international Delphi study will be performed to reach consensus on which and how measurement properties should be assessed, and on criteria for good measurement properties. Two sources of input will be used for the Delphi study: (1 a systematic review of properties, standards and criteria of measurement properties found in systematic reviews of measurement instruments, and (2 an additional literature search of methodological articles presenting a comprehensive checklist of standards and criteria. The Delphi study will consist of four (written Delphi rounds, with approximately 30 expert panel members with different backgrounds in clinical medicine, biostatistics, psychology, and epidemiology. The final checklist will

  19. A standardized imaging protocol for the endoscopic prediction of dysplasia within sessile serrated polyps (with video).

    Science.gov (United States)

    Tate, David J; Jayanna, Mahesh; Awadie, Halim; Desomer, Lobke; Lee, Ralph; Heitman, Steven J; Sidhu, Mayenaaz; Goodrick, Kathleen; Burgess, Nicholas G; Mahajan, Hema; McLeod, Duncan; Bourke, Michael J

    2018-01-01

    Dysplasia within sessile serrated polyps (SSPs) is difficult to detect and may be mistaken for an adenoma, risking incomplete resection of the background serrated tissue, and is strongly implicated in interval cancer after colonoscopy. The use of endoscopic imaging to detect dysplasia within SSPs has not been systematically studied. Consecutively detected SSPs ≥8 mm in size were evaluated by using a standardized imaging protocol at a tertiary-care endoscopy center over 3 years. Lesions suspected as SSPs were analyzed with high-definition white light then narrow-band imaging. A demarcated area with a neoplastic pit pattern (Kudo type III/IV, NICE type II) was sought among the serrated tissue. If this was detected, the lesion was labeled dysplastic (sessile serrated polyp with dysplasia); if not, it was labeled non-dysplastic (sessile serrated polyp without dysplasia). Histopathology was reviewed by 2 blinded specialist GI pathologists. A total of 141 SSPs were assessed in 83 patients. Median lesion size was 15.0 mm (interquartile range 10-20), and 54.6% were in the right side of the colon. Endoscopic evidence of dysplasia was detected in 36 of 141 (25.5%) SSPs; of these, 5 of 36 (13.9%) lacked dysplasia at histopathology. Two of 105 (1.9%) endoscopically designated non-dysplastic SSPs had dysplasia at histopathology. Endoscopic imaging, therefore, had an accuracy of 95.0% (95% confidence interval [CI], 90.1%-97.6%) and a negative predictive value of 98.1% (95% CI, 92.6%-99.7%) for detection of dysplasia within SSPs. Dysplasia within SSPs can be detected accurately by using a simple, broadly applicable endoscopic imaging protocol that allows complete resection. Independent validation of this protocol and its dissemination to the wider endoscopic community may have a significant impact on rates of interval cancer. (Clinical trial registration number: NCT03100552.). Copyright © 2018 American Society for Gastrointestinal Endoscopy. Published by Elsevier Inc. All

  20. An Advanced Encryption Standard Powered Mutual Authentication Protocol Based on Elliptic Curve Cryptography for RFID, Proven on WISP

    Directory of Open Access Journals (Sweden)

    Alaauldin Ibrahim

    2017-01-01

    Full Text Available Information in patients’ medical histories is subject to various security and privacy concerns. Meanwhile, any modification or error in a patient’s medical data may cause serious or even fatal harm. To protect and transfer this valuable and sensitive information in a secure manner, radio-frequency identification (RFID technology has been widely adopted in healthcare systems and is being deployed in many hospitals. In this paper, we propose a mutual authentication protocol for RFID tags based on elliptic curve cryptography and advanced encryption standard. Unlike existing authentication protocols, which only send the tag ID securely, the proposed protocol could also send the valuable data stored in the tag in an encrypted pattern. The proposed protocol is not simply a theoretical construct; it has been coded and tested on an experimental RFID tag. The proposed scheme achieves mutual authentication in just two steps and satisfies all the essential security requirements of RFID-based healthcare systems.

  1. Defining standardized protocols for determining the efficacy of a postmilking teat disinfectant following experimental exposure of teats to mastitis pathogens.

    Science.gov (United States)

    Schukken, Y H; Rauch, B J; Morelli, J

    2013-04-01

    The objective of this paper was to define standardized protocols for determining the efficacy of a postmilking teat disinfectant following experimental exposure of teats to both Staphylococcus aureus and Streptococcus agalactiae. The standardized protocols describe the selection of cows and herds and define the critical points in performing experimental exposure, performing bacterial culture, evaluating the culture results, and finally performing statistical analyses and reporting of the results. The protocols define both negative control and positive control trials. For negative control trials, the protocol states that an efficacy of reducing new intramammary infections (IMI) of at least 40% is required for a teat disinfectant to be considered effective. For positive control trials, noninferiority to a control disinfectant with a published efficacy of reducing new IMI of at least 70% is required. Sample sizes for both negative and positive control trials are calculated. Positive control trials are expected to require a large trial size. Statistical analysis methods are defined and, in the proposed methods, the rate of IMI may be analyzed using generalized linear mixed models. The efficacy of the test product can be evaluated while controlling for important covariates and confounders in the trial. Finally, standards for reporting are defined and reporting considerations are discussed. The use of the defined protocol is shown through presentation of the results of a recent trial of a test product against a negative control. Copyright © 2013 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.

  2. Wireless networking for the dental office: current wireless standards and security protocols.

    Science.gov (United States)

    Mupparapu, Muralidhar; Arora, Sarika

    2004-11-15

    Digital radiography has gained immense popularity in dentistry today in spite of the early difficulty for the profession to embrace the technology. The transition from film to digital has been happening at a faster pace in the fields of Orthodontics, Oral Surgery, Endodontics, Periodontics, and other specialties where the radiographic images (periapical, bitewing, panoramic, cephalometric, and skull radiographs) are being acquired digitally, stored within a server locally, and eventually accessed for diagnostic purposes, along with the rest of the patient data via the patient management software (PMS). A review of the literature shows the diagnostic performance of digital radiography is at least comparable to or even better than that of conventional radiography. Similarly, other digital diagnostic tools like caries detectors, cephalometric analysis software, and digital scanners were used for many years for the diagnosis and treatment planning purposes. The introduction of wireless charged-coupled device (CCD) sensors in early 2004 (Schick Technologies, Long Island City, NY) has moved digital radiography a step further into the wireless era. As with any emerging technology, there are concerns that should be looked into before adapting to the wireless environment. Foremost is the network security involved in the installation and usage of these wireless networks. This article deals with the existing standards and choices in wireless technologies that are available for implementation within a contemporary dental office. The network security protocols that protect the patient data and boost the efficiency of modern day dental clinics are enumerated.

  3. Epidemiological cut-off values for Flavobacterium psychrophilum MIC data generated by a standard test protocol.

    Science.gov (United States)

    Smith, P; Endris, R; Kronvall, G; Thomas, V; Verner-Jeffreys, D; Wilhelm, C; Dalsgaard, I

    2016-02-01

    Epidemiological cut-off values were developed for application to antibiotic susceptibility data for Flavobacterium psychrophilum generated by standard CLSI test protocols. The MIC values for ten antibiotic agents against Flavobacterium psychrophilum were determined in two laboratories. For five antibiotics, the data sets were of sufficient quality and quantity to allow the setting of valid epidemiological cut-off values. For these agents, the cut-off values, calculated by the application of the statistically based normalized resistance interpretation method, were ≤16 mg L(-1) for erythromycin, ≤2 mg L(-1) for florfenicol, ≤0.025 mg L(-1) for oxolinic acid (OXO), ≤0.125 mg L(-1) for oxytetracycline and ≤20 (1/19) mg L(-1) for trimethoprim/sulphamethoxazole. For ampicillin and amoxicillin, the majority of putative wild-type observations were 'off scale', and therefore, statistically valid cut-off values could not be calculated. For ormetoprim/sulphadimethoxine, the data were excessively diverse and a valid cut-off could not be determined. For flumequine, the putative wild-type data were extremely skewed, and for enrofloxacin, there was inadequate separation in the MIC values for putative wild-type and non-wild-type strains. It is argued that the adoption of OXO as a class representative for the quinolone group would be a valid method of determining susceptibilities to these agents. © 2014 John Wiley & Sons Ltd.

  4. A Two-Layered Mobility Architecture Using Fast Mobile IPv6 and Session Initiation Protocol

    Directory of Open Access Journals (Sweden)

    Nursimloo DeeyaS

    2008-01-01

    Full Text Available Abstract This paper proposes an integrated mobility scheme that combines the procedures of fast handover for Mobile IPv6 (FMIPv6 and session initiation protocol (SIP mobility for realtime communications. This integrated approach is based on the context of the applications utilized. Furthermore, to reduce system redundancies and signaling loads, several functionalities of FMIPv6 and SIP have been integrated to optimize the integrated mobility scheme. The proposed scheme aims at reducing the handover latency and packet loss for an ongoing realtime traffic. Using ns-2 simulation, we analyze the performance of the proposed integrated scheme and compare it with the existing protocols for a VoIP and for a video stream traffic. This mobility architecture achieves lower handover delay and less packet loss than using either FMIPv6 or SIP and hence presents a powerful handover mobility scheme for next generation IP-based wireless systems.

  5. A Two-Layered Mobility Architecture Using Fast Mobile IPv6 and Session Initiation Protocol

    Directory of Open Access Journals (Sweden)

    Deeya S. Nursimloo

    2007-12-01

    Full Text Available This paper proposes an integrated mobility scheme that combines the procedures of fast handover for Mobile IPv6 (FMIPv6 and session initiation protocol (SIP mobility for realtime communications. This integrated approach is based on the context of the applications utilized. Furthermore, to reduce system redundancies and signaling loads, several functionalities of FMIPv6 and SIP have been integrated to optimize the integrated mobility scheme. The proposed scheme aims at reducing the handover latency and packet loss for an ongoing realtime traffic. Using ns-2 simulation, we analyze the performance of the proposed integrated scheme and compare it with the existing protocols for a VoIP and for a video stream traffic. This mobility architecture achieves lower handover delay and less packet loss than using either FMIPv6 or SIP and hence presents a powerful handover mobility scheme for next generation IP-based wireless systems.

  6. A Review of Protocol Implementations and Energy Efficient Cross-Layer Design for Wireless Body Area Networks

    Directory of Open Access Journals (Sweden)

    Tao Chen

    2012-11-01

    Full Text Available The issues inherent in caring for an ever-increasing aged population has been the subject of endless debate and continues to be a hot topic for political discussion. The use of hospital-based facilities for the monitoring of chronic physiological conditions is expensive and ties up key healthcare professionals. The introduction of wireless sensor devices as part of a Wireless Body Area Network (WBAN integrated within an overall eHealth solution could bring a step change in the remote management of patient healthcare. Sensor devices small enough to be placed either inside or on the human body can form a vital part of an overall health monitoring network. An effectively designed energy efficient WBAN should have a minimal impact on the mobility and lifestyle of the patient. WBAN technology can be deployed within a hospital, care home environment or in the patient’s own home. This study is a review of the existing research in the area of WBAN technology and in particular protocol adaptation and energy efficient cross-layer design. The research reviews the work carried out across various layers of the protocol stack and highlights how the latest research proposes to resolve the various challenges inherent in remote continual healthcare monitoring.

  7. A transport layer protocol for the future high speed grid computing: SCTP versus fast tcp multihoming

    International Nuclear Information System (INIS)

    Arshad, M.J.; Mian, M.S.

    2010-01-01

    TCP (Transmission Control Protocol) is designed for reliable data transfer on the global Internet today. One of its strong points is its use of flow control algorithm that allows TCP to adjust its congestion window if network congestion is occurred. A number of studies and investigations have confirmed that traditional TCP is not suitable for each and every type of application, for example, bulk data transfer over high speed long distance networks. TCP sustained the time of low-capacity and short-delay networks, however, for numerous factors it cannot be capable to efficiently deal with today's growing technologies (such as wide area Grid computing and optical-fiber networks). This research work surveys the congestion control mechanism of transport protocols, and addresses the different issues involved for transferring the huge data over the future high speed Grid computing and optical-fiber networks. This work also presents the simulations to compare the performance of FAST TCP multihoming with SCTP (Stream Control Transmission Protocol) multihoming in high speed networks. These simulation results show that FAST TCP multihoming achieves bandwidth aggregation efficiently and outperforms SCTP multihoming under a similar network conditions. The survey and simulation results presented in this work reveal that multihoming support into FAST TCP does provide a lot of benefits like redundancy, load-sharing and policy-based routing, which largely improves the whole performance of a network and can meet the increasing demand of the future high-speed network infrastructures (such as in Grid computing). (author)

  8. Non operative management of blunt splenic trauma: a prospective evaluation of a standardized treatment protocol.

    Science.gov (United States)

    Brillantino, A; Iacobellis, F; Robustelli, U; Villamaina, E; Maglione, F; Colletti, O; De Palma, M; Paladino, F; Noschese, G

    2016-10-01

    The advantages of the conservative approach for major spleen injuries are still debated. This study was designed to evaluate the safety and effectiveness of NOM in the treatment of minor (grade I-II according with the American Association for the Surgery of Trauma; AAST) and severe (AAST grade III-V) blunt splenic trauma, following a standardized treatment protocol. All the hemodynamically stable patients with computer tomography (CT) diagnosis of blunt splenic trauma underwent NOM, which included strict clinical and laboratory observation, 48-72 h contrast-enhanced ultrasonography (CEUS) follow-up and splenic angioembolization, performed both in patients with admission CT evidence of vascular injuries and in patients with falling hematocrit during observation. 87 patients [32 (36.7 %) women and 55 (63.2 %) men, median age 34 (range 14-68)] were included. Of these, 28 patients (32.1 %) had grade I, 22 patients (25.2 %) grade II, 20 patients (22.9 %) grade III, 11 patients (12.6 %) grade IV and 6 patients (6.8 %) grade V injuries. The overall success rate of NOM was 95.4 % (82/87). There was no significant difference in the success rate between the patients with different splenic injuries grade. Of 24 patients that had undergone angioembolization, 22 (91.6 %) showed high splenic injury grade. The success rate of embolization was 91.6 % (22/24). No major complications were observed. The minor complications (2 pleural effusions, 1 pancreatic fistula and 2 splenic abscesses) were successfully treated by EAUS or CT guided drainage. The non operative management of blunt splenic trauma, according to our protocol, represents a safe and effective treatment for both minor and severe injuries, achieving an overall success rate of 95 %. The angiographic study could be indicated both in patients with CT evidence of vascular injuries and in patients with high-grade splenic injuries, regardless of CT findings.

  9. Layering of IFRS and Dual Institutionality of Accounting Standards in Belarus

    OpenAIRE

    Alexander, David; Alon, Anna

    2017-01-01

    Submitted version of an article published in the journal Accounting in Europe. There is an ongoing debate about the applicability and efficacy of International Financial Reporting Standards (IFRS) adoption in countries with diverse institutional infrastructures. We examine financial reporting in Belarus and factors that are shaping its development. In Belarus, IFRS has been adopted through layering where it is an additional requirement to the existing reporting specified by the national ac...

  10. Network Coding to Enhance Standard Routing Protocols in Wireless Mesh Networks

    DEFF Research Database (Denmark)

    Pahlevani, Peyman; Roetter, Daniel Enrique Lucani; Fitzek, Frank

    2013-01-01

    This paper introduces a design and simulation of a locally optimized network coding protocol, called PlayNCool, for wireless mesh networks. PlayN-Cool is easy to implement and compatible with existing routing protocols and devices. This allows the system to gain from network coding capabilities i...

  11. Energy-Efficient Link-Layer Jamming Attacks against Wireless Sensor Network MAC Protocols

    NARCIS (Netherlands)

    Law, Y.W.; van Hoesel, L.F.W.; Doumen, J.M.; Hartel, Pieter H.; Havinga, Paul J.M.; Atluri, V.; Samarati, P.; Ning, P.; Du, W.

    2005-01-01

    A typical wireless sensor node has little protection against radio jamming. The situation becomes worse if energy efficient jamming can be achieved by exploiting knowledge of the data link layer. Encrypting the packets may help prevent the jammer from taking actions based on the content of the

  12. Performance Analysis of IEEE 802.11e (EDCF) and IEEE 802.11(DCF) WLAN Incorporating Different Physical Layer Standards

    Science.gov (United States)

    Sharma, V.; Singh, H.; Malhotra, J.

    2012-12-01

    Medium access coordination function basically implements the distributed coordination function (DCF) which provides support to best effort services but limited to QoS services. Subsequently, a new standard, namely enhanced distributed channel access (EDCA) is reported. The IEEE 802.11e (EDCA) defines MAC procedures to support QoS requirements which specifies distributed contention based access scheme to access the shared wireless media. This paper evaluates the performance of EDCA based IEEE 802.11 WLAN for various access categories (ACs) using OPNET™ Modeller 14.5. Further, the computed results are compared with DCF protocols in terms of QoS parameters. Furthermore, the simulative observation is reported at data rate of 54 Mbps using different physical layer protocols such as IEEE 802.11a/b/g to stumble on the best one to be implemented with EDCF to achieve improved QoS.

  13. Dual-energy CT workflow: multi-institutional consensus on standardization of abdominopelvic MDCT protocols.

    Science.gov (United States)

    Patel, Bhavik N; Alexander, Lauren; Allen, Brian; Berland, Lincoln; Borhani, Amir; Mileto, Achille; Moreno, Courtney; Morgan, Desiree; Sahani, Dushyant; Shuman, William; Tamm, Eric; Tublin, Mitchell; Yeh, Benjamin; Marin, Daniele

    2017-03-01

    To standardize workflow for dual-energy computed tomography (DECT) involving common abdominopelvic exam protocols. 9 institutions (4 rsDECT, 1 dsDECT, 4 both) with 32 participants [average # years (range) in practice and DECT experience, 12.3 (1-35) and 4.6 (1-14), respectively] filled out a single survey (n = 9). A five-point agreement scale (0, 1, 2, 3, 4-contra-, not, mildly, moderately, strongly indicated, respectively) and utilization scale (0-not performing and shouldn't; 1-performing but not clinically useful; 2-performing but not sure if clinically useful; 3-not performing it but would like to; 4-performing and clinically useful) were used. Consensus was considered with a score of ≥2.5. Survey results were discussed over three separate live webinar sessions. 5/9 (56%) institutions exclude large patients from DECT. 2 (40%) use weight, 2 (40%) use transverse dimension, and 1 (20%) uses both. 7/9 (78%) use 50 keV for low and 70 keV for medium monochromatic reconstructed images. DECT is indicated for dual liver [agreement score (AS) 3.78; utilization score (US) 3.22] and dual pancreas in the arterial phase (AS 3.78; US 3.11), mesenteric ischemia/gastrointestinal bleeding in both the arterial and venous phases (AS 2.89; US 2.79), RCC exams in the arterial phase (AS 3.33; US 2.78), and CT urography in the nephrographic phase (AS 3.11; US 2.89). DECT for renal stone and certain single-phase exams is indicated (AS 3.00). DECT is indicated during the arterial phase for multiphasic abdominal exams, nephrographic phase for CTU, and for certain single-phase and renal stone exams.

  14. Shortened screening method for phosphorus fractionation in sediments A complementary approach to the standards, measurements and testing harmonised protocol

    International Nuclear Information System (INIS)

    Pardo, Patricia; Rauret, Gemma; Lopez-Sanchez, Jose Fermin

    2004-01-01

    The SMT protocol, a sediment phosphorus fractionation method harmonised and validated in the frame of the standards, measurements and testing (SMT) programme (European Commission), establishes five fractions of phosphorus according to their extractability. The determination of phosphate extracted is carried out spectrophotometrically. This protocol has been applied to 11 sediments of different origin and characteristics and the phosphorus extracted in each fraction was determined not only by UV-Vis spectrophotometry, but also by inductively coupled plasma-atomic emission spectrometry. The use of these two determination techniques allowed the differentiation between phosphorus that was present in the extracts as soluble reactive phosphorus and as total phosphorus. From the comparison of data obtained with both determination techniques a shortened screening method, for a quick evaluation of the magnitude and importance of the fractions given by the SMT protocol, is proposed and validated using two certified reference materials

  15. Standardizing data exchange for clinical research protocols and case report forms: An assessment of the suitability of the Clinical Data Interchange Standards Consortium (CDISC) Operational Data Model (ODM).

    Science.gov (United States)

    Huser, Vojtech; Sastry, Chandan; Breymaier, Matthew; Idriss, Asma; Cimino, James J

    2015-10-01

    Efficient communication of a clinical study protocol and case report forms during all stages of a human clinical study is important for many stakeholders. An electronic and structured study representation format that can be used throughout the whole study life-span can improve such communication and potentially lower total study costs. The most relevant standard for representing clinical study data, applicable to unregulated as well as regulated studies, is the Operational Data Model (ODM) in development since 1999 by the Clinical Data Interchange Standards Consortium (CDISC). ODM's initial objective was exchange of case report forms data but it is increasingly utilized in other contexts. An ODM extension called Study Design Model, introduced in 2011, provides additional protocol representation elements. Using a case study approach, we evaluated ODM's ability to capture all necessary protocol elements during a complete clinical study lifecycle in the Intramural Research Program of the National Institutes of Health. ODM offers the advantage of a single format for institutions that deal with hundreds or thousands of concurrent clinical studies and maintain a data warehouse for these studies. For each study stage, we present a list of gaps in the ODM standard and identify necessary vendor or institutional extensions that can compensate for such gaps. The current version of ODM (1.3.2) has only partial support for study protocol and study registration data mainly because it is outside the original development goal. ODM provides comprehensive support for representation of case report forms (in both the design stage and with patient level data). Inclusion of requirements of observational, non-regulated or investigator-initiated studies (outside Food and Drug Administration (FDA) regulation) can further improve future revisions of the standard. Published by Elsevier Inc.

  16. The effect of the introduction of a standard monitoring protocol on ...

    African Journals Online (AJOL)

    2011-03-07

    Mar 7, 2011 ... management protocol had had any effect on the metabolic and nonmetabolic .... Ages were not recorded. ..... of happiness and wealth.14 Three-quarters of the girls associated ... Information on lifestyle and advice to reduce.

  17. Optimization of Saanen sperm genes amplification: evaluation of standardized protocols in genetically uncharacterized rural goats reared under a subtropical environment.

    Science.gov (United States)

    Barbour, Elie K; Saade, Maya F; Sleiman, Fawwak T; Hamadeh, Shady K; Mouneimne, Youssef; Kassaifi, Zeina; Kayali, Ghazi; Harakeh, Steve; Jaber, Lina S; Shaib, Houssam A

    2012-10-01

    The purpose of this research is to optimize quantitatively the amplification of specific sperm genes in reference genomically characterized Saanen goat and to evaluate the standardized protocols applicability on sperms of uncharacterized genome of rural goats reared under subtropical environment for inclusion in future selection programs. The optimization of the protocols in Saanen sperms included three production genes (growth hormone (GH) exons 2, 3, and 4, αS1-casein (CSN1S1), and α-lactalbumin) and two health genes (MHC class II DRB and prion (PrP)). The optimization was based on varying the primers concentrations and the inclusion of a PCR cosolvent (Triton X). The impact of the studied variables on statistically significant increase in the yield of amplicons was noticed in four out of five (80%) optimized protocols, namely in those related to GH, CSN1S1, α-lactalbumin, and PrP genes (P 0.05). The applicability of the optimized protocols of Saanen sperm genes on amplification of uncharacterized rural goat sperms revealed a 100% success in tested individuals for amplification of GH, CSN1S1, α-lactalbumin, and MHC class II DRB genes and a 75% success for the PrP gene. The significant success in applicability of the Saanen quantitatively optimized protocols to other uncharacterized genome of rural goats allows for their inclusion in future selection, targeting the sustainability of this farming system in a subtropical environment and the improvement of the farmers livelihood.

  18. ANALISIS QOS PADA PEMBAGIAN BANDWIDTH DENGAN METODE LAYER 7 PROTOCOL, PCQ, HTB DAN HOTSPOT DI SMK SWASTA AL-WASHLIYAH PASAR SENEN

    Directory of Open Access Journals (Sweden)

    Dian Kurnia

    2017-07-01

    Full Text Available Pada penelitian ini akan dilakukan analisis QoS Pada Pembagian Bandwidth menggunakan metode HTB (Hierarchical Tocken Bucket, PCQ(Per Connection Queue  dengan Layer 7 protocol sebagai limit file berekstensi, PCQ dan Hotspot. Pada HTB menggunakan teknik antrian queue tree, PCQ dengan Layer 7 protocol, PCQ menggunakan teknik antrian simple queue, hotspot menggunakan teknik antrian simple queue. Sehingga didapat perbandingan dari metode HTB (Hierarchical Tocken Bucket, PCQ dengan Layer 7 protocol, PCQ dan hotspot akan diterapkan pada mikrotik RB750GL. Hasil akhir penelitian ini diukur dengan parameter-parameter QoS throughput, delay (latency, jitter (variasi kedatangan paket, Packet loss. Adapun hasil pengujian dalam penelitian ini dilakukan pada trafik jam sibuk untuk mengetahui sejauh mana kinerja performansi management bandwidth dengan metode-metode tersebut. Dari hasil penelitian untuk performance QoS yang lebih baik untuk memanagement bandwidth di dapat nilai throughput, jitter dan delay terbaik yaitu menggunakan metode HTB.

  19. Standards and Protocols for Digital Libraries Dijital Kütüphanelerde Standartlar ve Protokoller

    Directory of Open Access Journals (Sweden)

    Mehmet Emin Küçük

    2003-06-01

    Full Text Available New paradigms have been emerged in the field of librarianship and publishing with the developments in electronic environment, and rapid increase in electronically archived information and its acquisition and retrieval. While libraries show more interest in electronic information, publishers' current tendency is towards production of electronic information. In addition to the acquisition of electronic information, libraries have begun to digitise some of the holdings which do not present copyright problems. Economies provided by digitised information in terms of archiving, sharing and retrieval as well as the users' requirements are the basic motivation for digitisation. However, digital library standards have vital roles in performing effective library cooperation and interoperability between the systems. In this descriptive study, "the most commonly" confronted standards in digital library applications are being examined and evaluated under the following headings; (i record structure standards, (ii encoding standards, and (iii communication standards and protocols. However, metadata standards which can be categorised in record structure standards are not included since the matters are well studied in several papers in Turkish. Elektronik ortamdaki gelişmeler ve elektronik ortamda depolanan bilginin artmasıyla bilginin sağlanması, depolanması ve erişimi konularında önemli değişiklikler meydana gelmiş, yayıncılık ve kütüphanecilikte yeni paradigmaların oluşmasına neden olmuştur. Yayıncılar kaynakları elektronik ortamda üretme eğilimi göstermeye başlarken kütüphaneler de elektronik kaynaklara daha çok ilgi gösterir olmuşlardır. Elektronik ortamda üretilen kaynakların sağlanmasının yanı sıra, bir dizi kütüphane, dermelerinde bulunan ve telif sorunu olmayan materyali dijitalle sürerek kullanıcılarının hizmetine sunmaya başlamıştır. Dijital ortamda bilginin çok daha rahat depolanması, payla

  20. Fast and easy protocol for the purification of recombinant S-layer protein for synthetic biology applications

    KAUST Repository

    Norville, Julie E.

    2011-06-17

    A goal of synthetic biology is to make biological systems easier to engineer. One of the aims is to design, with nanometer-scale precision, biomaterials with well-defined properties. The surface-layer protein SbpA forms 2D arrays naturally on the cell surface of Lysinibacillus sphaericus, but also as the purified protein in solution upon the addition of divalent cations. The high propensity of SbpA to form crystalline arrays, which can be simply controlled by divalent cations, and the possibility to genetically alter the protein, make SbpA an attractive molecule for synthetic biology. To be a useful tool, however, it is important that a simple protocol can be used to produce recombinant wild-type and modified SbpA in large quantities and in a biologically active form. The present study addresses this requirement by introducing a mild and non-denaturing purification protocol to produce milligram quantities of recombinant, active SbpA.

  1. Investigating And Evaluating Of Network Failures And Performance Over Distributed WAN In Application Protocol Layer

    Directory of Open Access Journals (Sweden)

    Enoch Okoh Kofi

    2015-08-01

    Full Text Available The Experiment was done to find out network failures and application performance relationship over distributed Wide Area Net WAN. In order to access related application over the cloud there must be an internet connectivity which will help the respective workstations to access the remote server for applications being deployed over the network. Bandwidth improvement helps in reducing utilization over the network and it also helps in improving Application Efficiency of these Applications in terms of Response Time. Routers were configured under Enhance Interior Gateway Routing Protocol EIGRP to reduce utilization and to ensure load sharing over the network. Three scenarios were modeled and their performance efficiency was evaluated. A modeled computer Network with and without a fail Router under different scenarios and such Network was simulated with emphasis on the Application Performance. The Experiment was done for fifty workstations under three scenarios and these three scenarios were accessed and evaluated on experimental basis using Riverbed modeler to show the Effect of Application Network performance. The performance results show that increasing the bandwidth reduces utilization and also with the failure of one communication bandwidth users can still access Network Application with a minimal cost.

  2. Summary Report Panel 1: The Need for Protocols and Standards in Research on Underwater Noise Impacts on Marine Life.

    Science.gov (United States)

    Erbe, Christine; Ainslie, Michael A; de Jong, Christ A F; Racca, Roberto; Stocker, Michael

    2016-01-01

    As concern about anthropogenic noise and its impacts on marine fauna is increasing around the globe, data are being compared across populations, species, noise sources, geographic regions, and time. However, much of the raw and processed data are not comparable due to differences in measurement methodology, analysis and reporting, and a lack of metadata. Common protocols and more formal, international standards are needed to ensure the effectiveness of research, conservation, regulation and practice, and unambiguous communication of information and ideas. Developing standards takes time and effort, is largely driven by a few expert volunteers, and would benefit from stakeholders' contribution and support.

  3. A Web Resource for Standardized Benchmark Datasets, Metrics, and Rosetta Protocols for Macromolecular Modeling and Design.

    Directory of Open Access Journals (Sweden)

    Shane Ó Conchúir

    Full Text Available The development and validation of computational macromolecular modeling and design methods depend on suitable benchmark datasets and informative metrics for comparing protocols. In addition, if a method is intended to be adopted broadly in diverse biological applications, there needs to be information on appropriate parameters for each protocol, as well as metrics describing the expected accuracy compared to experimental data. In certain disciplines, there exist established benchmarks and public resources where experts in a particular methodology are encouraged to supply their most efficient implementation of each particular benchmark. We aim to provide such a resource for protocols in macromolecular modeling and design. We present a freely accessible web resource (https://kortemmelab.ucsf.edu/benchmarks to guide the development of protocols for protein modeling and design. The site provides benchmark datasets and metrics to compare the performance of a variety of modeling protocols using different computational sampling methods and energy functions, providing a "best practice" set of parameters for each method. Each benchmark has an associated downloadable benchmark capture archive containing the input files, analysis scripts, and tutorials for running the benchmark. The captures may be run with any suitable modeling method; we supply command lines for running the benchmarks using the Rosetta software suite. We have compiled initial benchmarks for the resource spanning three key areas: prediction of energetic effects of mutations, protein design, and protein structure prediction, each with associated state-of-the-art modeling protocols. With the help of the wider macromolecular modeling community, we hope to expand the variety of benchmarks included on the website and continue to evaluate new iterations of current methods as they become available.

  4. Report on the results of the FY1999 standardization for new standard interface protocol for electrical measuring use; 1999 nendo shinki sangyo ikusei sokkogata kokusai hyojun kaihatsu jigyo seika hokokusho. Denki keisokukiyo shinhyojun interface purotokoru no hyojunka

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2000-03-01

    The purpose of this project is to create a new protocol for electric measuring instruments that use a built-in the Universal Serial Bus (USB) interface which is no incorporated in PCs. This new interface will replace the existing GPIB interface (IEEE-488), which is currently used in electric measuring instruments as standard interface. Our goal is to create a protocol that will provide the same data rate as GPIB and better connectivity. To evaluate our new protocol, we create virtual instruments using evaluation boards for USB chips, as well as software, and performed transfer tests to isolate and solve problems found in the tests. We will make the protocol and the software available for general use, and register the protocol as a standard to the USB Developer's Forum, a body that manages USB standards, to make it as a de facto standard. Ultimately we are aiming at making it an international standard. (NEDO)

  5. Diurnal Dynamics of Standard Deviations of Three Wind Velocity Components in the Atmospheric Boundary Layer

    Science.gov (United States)

    Shamanaeva, L. G.; Krasnenko, N. P.; Kapegesheva, O. F.

    2018-04-01

    Diurnal dynamics of the standard deviation (SD) of three wind velocity components measured with a minisodar in the atmospheric boundary layer is analyzed. Statistical analysis of measurement data demonstrates that the SDs for x- and y-components σx and σy lie in the range from 0.2 to 4 m/s, and σz = 0.1-1.2 m/s. The increase of σx and σy with the altitude is described sufficiently well by a power law with exponent changing from 0.22 to 1.3 depending on time of day, and σz increases by a linear law. Approximation constants are determined and errors of their application are estimated. It is found that the maximal diurnal spread of SD values is 56% for σx and σy and 94% for σz. The established physical laws and the obtained approximation constants allow the diurnal dynamics of the SDs for three wind velocity components in the atmospheric boundary layer to be determined and can be recommended for application in models of the atmospheric boundary layer.

  6. MgAl-Layered Double Hydroxide Solid Base Catalysts for Henry Reaction: A Green Protocol

    Directory of Open Access Journals (Sweden)

    Magda H. Abdellattif

    2018-03-01

    Full Text Available A series of MgAl-layered double hydroxide (MgAl-HT, the calcined form at 500 °C (MgAlOx, and the rehydrated one at 25 °C (MgAl-HT-RH were synthesized. Physicochemical properties of the catalysts were characterized by X-ray diffraction (XRD and scanning electron microscopy (SEM. Surface area of the as-synthesized, calcined, and rehydrated catalysts was determined by N2 physisorption at −196 °C. CO2 temperature-programmed desorption (CO2-TPD was applied to determine the basic sites of catalysts. The catalytic test reaction was carried out using benzaldehyde and their derivatives with nitromethane and their derivatives. The Henry products (1–15 were obtained in a very good yield using MgAl-HT-RH catalyst either by conventional method at 90 °C in liquid phase or under microwave irradiation method. The mesoporous structure and basic nature of the rehydrated solid catalyst were responsible for its superior catalytic efficiency. The robust nature was determined by using the same catalyst five times, where the product % yield was almost unchanged significantly.

  7. Psychometric Properties of a Standardized Observation Protocol to Quantify Pediatric Physical Therapy Actions

    NARCIS (Netherlands)

    Sonderer, Patrizia; Ziegler, Schirin Akhbari; Oertle, Barbara Gressbach; Meichtry, Andre; Hadders-Algra, Mijna

    Purpose: Pediatric physical therapy (PPT) is characterized by heterogeneity. This blurs the evaluation of effective components of PPT. The Groningen Observation Protocol (GOP) was developed to quantify contents of PPT. This study assesses the reliability and completeness of the GOP. Methods: Sixty

  8. 75 FR 4323 - Additional Quantitative Fit-testing Protocols for the Respiratory Protection Standard

    Science.gov (United States)

    2010-01-27

    ...-mask and full face piece respirators are normally considered two different types of air purifying... article published in a peer-reviewed industrial-hygiene journal describing the protocol and explaining how... article from an industrial- hygiene journal describing the accuracy and reliability of these proposed...

  9. A Real-Time GPP Software-Defined Radio Testbed for the Physical Layer of Wireless Standards

    NARCIS (Netherlands)

    Schiphorst, Roelof; Hoeksema, F.W.; Slump, Cornelis H.

    2005-01-01

    We present our contribution to the general-purpose-processor-(GPP)-based radio. We describe a baseband software-defined radio testbed for the physical layer of wireless LAN standards. All physical layer functions have been successfully mapped on a Pentium 4 processor that performs these functions in

  10. Analysis of 855 upper extremity fistulas created using a standard protocol: the role of graft extension to achieve functional status.

    Science.gov (United States)

    Allan, Bassan J; Perez, Enrique R; Tabbara, Marwan

    2013-06-01

    The Fistula First Breakthrough Initiative (FFBI) has been one of the most important national programs to help achieve considerable improvements in the care of patients on chronic hemodialysis. FFBI has helped place guidelines to push practitioners to reduce the use of tunneled central venous catheters and to increase the rate of arteriovenous fistula use in patients requiring chronic hemodialysis access. However, despite current guidelines, no specific protocols exist for the creation and management of autogenous arteriovenous fistulas and outcomes at most centers are below national benchmarks. In this study, we examine the effectiveness of a standard protocol used at our institution for the creation of autogenous upper extremity fistulas for hemodialysis access in achieving early cannulation and early removal of tunneled dialysis catheters. Our review encompasses 855 consecutive autogenous fistulas created over a 10-year period. Our findings suggest that the use of a standard protocol for creation and management of autogenous fistulas can help increase the rate of functional accesses over national benchmarks. Additionally, extension/conversion of malfunctioning fistulas to grafts appears to be an excellent method to expedite removal of a tunneled dialysis catheter with concomitant preservation of a fistula.

  11. 78 FR 45096 - Standards for Business Practices and Communication Protocols for Public Utilities

    Science.gov (United States)

    2013-07-26

    ... Related to Terms, Definition and 24 Acronyms 6. Commission Proposal 24 D. Implementation 24 III. Notice of... between the two markets \\5\\ and re-organized and revised definitions to create a standard set of terms, definitions and acronyms applicable to all NAESB WEQ standards.\\6\\ NAESB states that the Version 003 Standards...

  12. CPM Test-Retest Reliability: "Standard" vs "Single Test-Stimulus" Protocols.

    Science.gov (United States)

    Granovsky, Yelena; Miller-Barmak, Adi; Goldstein, Oren; Sprecher, Elliot; Yarnitsky, David

    2016-03-01

    Assessment of pain inhibitory mechanisms using conditioned pain modulation (CPM) is relevant clinically in prediction of pain and analgesic efficacy. Our objective is to provide necessary estimates of intersession CPM reliability, to enable transformation of the CPM paradigm into a clinical tool. Two cohorts of young healthy subjects (N = 65) participated in two dual-session studies. In Study I, a Bath-Thermode CPM protocol was used, with hot water immersion and contact heat as conditioning- and test-stimuli, respectively, in a classical parallel CPM design introducing test-stimulus first, and then the conditioning- and repeated test-stimuli in parallel. Study II consisted of two CPM protocols: 1) Two-Thermodes, one for each of the stimuli, in the same parallel design as above, and 2) single test-stimulus (STS) protocol with a single administration of a contact heat test-stimulus, partially overlapped in time by a remote shorter contact heat as conditioning stimulus. Test-retest reliability was assessed within 3-7 days. The STS-CPM had superior reliability intraclass correlation (ICC 2 ,: 1  = 0.59) over Bath-Thermode (ICC 2 ,: 1  = 0.34) or Two-Thermodes (ICC 2 ,: 1  = 0.21) protocols. The hand immersion conditioning pain had higher reliability than thermode pain (ICC 2 ,: 1  = 0.76 vs ICC 2 ,: 1  = 0.16). Conditioned test-stimulus pain scores were of good (ICC 2 ,: 1  = 0.62) or fair (ICC 2 ,: 1  = 0.43) reliability for the Bath-Thermode and the STS, respectively, but not for the Two-Thermodes protocol (ICC 2 ,: 1  = 0.20). The newly developed STS-CPM paradigm was more reliable than other CPM protocols tested here, and should be further investigated for its clinical relevance. It appears that large contact size of the conditioning-stimulus and use of single rather than dual test-stimulus pain contribute to augmentation of CPM reliability. © 2015 American Academy of Pain Medicine. All rights reserved. For permissions, please e

  13. Distributed Processing System for Restoration of Electric Power Distribution Network Using Two-Layered Contract Net Protocol

    Science.gov (United States)

    Kodama, Yu; Hamagami, Tomoki

    Distributed processing system for restoration of electric power distribution network using two-layered CNP is proposed. The goal of this study is to develop the restoration system which adjusts to the future power network with distributed generators. The state of the art of this study is that the two-layered CNP is applied for the distributed computing environment in practical use. The two-layered CNP has two classes of agents, named field agent and operating agent in the network. In order to avoid conflicts of tasks, operating agent controls privilege for managers to send the task announcement messages in CNP. This technique realizes the coordination between agents which work asynchronously in parallel with others. Moreover, this study implements the distributed processing system using a de-fact standard multi-agent framework, JADE(Java Agent DEvelopment framework). This study conducts the simulation experiments of power distribution network restoration and compares the proposed system with the previous system. We confirmed the results show effectiveness of the proposed system.

  14. A protocol using coho salmon to monitor Tongass National Forest Land and Resource Management Plan standards and guidelines for fish habitat.

    Science.gov (United States)

    M.D. Bryant; Trent McDonald; R. Aho; B.E. Wright; Michelle Bourassa Stahl

    2008-01-01

    We describe a protocol to monitor the effectiveness of the Tongass Land Management Plan (TLMP) management standards for maintaining fish habitat. The protocol uses juvenile coho salmon (Oncorhynchus kisutch) in small tributary streams in forested watersheds. We used a 3-year pilot study to develop detailed methods to estimate juvenile salmonid...

  15. A standard data access layer for fusion devices R and D programs

    Energy Technology Data Exchange (ETDEWEB)

    Neto, A. [Associacao Euratom/IST, Centro de Fusao Nuclear, Av. Rovisco Pais, P-1049-001 Lisboa (Portugal); Fernandes, H. [Associacao Euratom/IST, Centro de Fusao Nuclear, Av. Rovisco Pais, P-1049-001 Lisboa (Portugal)], E-mail: hf@cfn.ist.utl.pt; Alves, D.; Valcarcel, D.F.; Carvalho, B.B.; Ferreira, J. [Associacao Euratom/IST, Centro de Fusao Nuclear, Av. Rovisco Pais, P-1049-001 Lisboa (Portugal); Vega, J.; Sanchez, E.; Pena, A. [Asociacion Euratom/CIEMAT para Fusion, Madrid (Spain); Hron, M. [Asociace EURATOM IPP.CR, Prague (Czech Republic); Varandas, C.A.F. [Associacao Euratom/IST, Centro de Fusao Nuclear, Av. Rovisco Pais, P-1049-001 Lisboa (Portugal)

    2007-10-15

    Each EURATOM Association stores data using proprietary schemes, usually developed by the research unit or using third party software. The temporary exchange of researchers between laboratories is a common practice nowadays. When the researchers returns to the home laboratory, there is usually the need to follow the work. The amount of available data is becoming enormous and the main data index is changing from shot number to time and events, where the pulse number is just one among the most relevant events against data is catalogued. These difficulties can be overcome by using a common software layer between end-users and laboratories. The components needed to create this software abstraction layer, between users and laboratories data, have already been developed using a universal and well known remote procedure call standard (RPC) based on the eXtensible Markup Language (XML): XML-RPC. The library allows data retrieval using the same methods for all associations. Users are authenticated through the PAPI system ( (http://papi.rediris.es)), allowing each organization to use its own authentication schema. Presently there are libraries and server implementations in Java and C++. These libraries have been included and tested in some of the most common data analysis programs such as MatLab and IDL. The system is already being used in ISTTOK/PT and CASTOR/CZ.

  16. A standard data access layer for fusion devices R and D programs

    International Nuclear Information System (INIS)

    Neto, A.; Fernandes, H.; Alves, D.; Valcarcel, D.F.; Carvalho, B.B.; Ferreira, J.; Vega, J.; Sanchez, E.; Pena, A.; Hron, M.; Varandas, C.A.F.

    2007-01-01

    Each EURATOM Association stores data using proprietary schemes, usually developed by the research unit or using third party software. The temporary exchange of researchers between laboratories is a common practice nowadays. When the researchers returns to the home laboratory, there is usually the need to follow the work. The amount of available data is becoming enormous and the main data index is changing from shot number to time and events, where the pulse number is just one among the most relevant events against data is catalogued. These difficulties can be overcome by using a common software layer between end-users and laboratories. The components needed to create this software abstraction layer, between users and laboratories data, have already been developed using a universal and well known remote procedure call standard (RPC) based on the eXtensible Markup Language (XML): XML-RPC. The library allows data retrieval using the same methods for all associations. Users are authenticated through the PAPI system ( (http://papi.rediris.es)), allowing each organization to use its own authentication schema. Presently there are libraries and server implementations in Java and C++. These libraries have been included and tested in some of the most common data analysis programs such as MatLab and IDL. The system is already being used in ISTTOK/PT and CASTOR/CZ

  17. Establishment and intra-/inter-laboratory validation of a standard protocol of reactive oxygen species assay for chemical photosafety evaluation.

    Science.gov (United States)

    Onoue, Satomi; Hosoi, Kazuhiro; Wakuri, Shinobu; Iwase, Yumiko; Yamamoto, Toshinobu; Matsuoka, Naoko; Nakamura, Kazuichi; Toda, Tsuguto; Takagi, Hironori; Osaki, Naoto; Matsumoto, Yasuhiro; Kawakami, Satoru; Seto, Yoshiki; Kato, Masashi; Yamada, Shizuo; Ohno, Yasuo; Kojima, Hajime

    2013-11-01

    A reactive oxygen species (ROS) assay was previously developed for photosafety evaluation of pharmaceuticals, and the present multi-center study aimed to establish and validate a standard protocol for ROS assay. In three participating laboratories, two standards and 42 coded chemicals, including 23 phototoxins and 19 nonphototoxic drugs/chemicals, were assessed by the ROS assay according to the standardized protocol. Most phototoxins tended to generate singlet oxygen and/or superoxide under UV-vis exposure, but nonphototoxic chemicals were less photoreactive. In the ROS assay on quinine (200 µm), a typical phototoxic drug, the intra- and inter-day precisions (coefficient of variation; CV) were found to be 1.5-7.4% and 1.7-9.3%, respectively. The inter-laboratory CV for quinine averaged 15.4% for singlet oxygen and 17.0% for superoxide. The ROS assay on 42 coded chemicals (200 µm) provided no false negative predictions upon previously defined criteria as compared with the in vitro/in vivo phototoxicity, although several false positives appeared. Outcomes from the validation study were indicative of satisfactory transferability, intra- and inter-laboratory variability, and predictive capacity of the ROS assay. Copyright © 2012 John Wiley & Sons, Ltd.

  18. Smart maintenance of riverbanks using a standard data layer and Augmented Reality

    Science.gov (United States)

    Pierdicca, Roberto; Frontoni, Emanuele; Zingaretti, Primo; Mancini, Adriano; Malinverni, Eva Savina; Tassetti, Anna Nora; Marcheggiani, Ernesto; Galli, Andrea

    2016-10-01

    Linear buffer strips (BS) along watercourses are commonly adopted to reduce run-off, accumulation of bank-top sediments and the leaking of pesticides into fresh-waters, which strongly increase water pollution. However, the monitoring of their conditions is a difficult task because they are scattered over wide rural areas. This work demonstrates the benefits of using a standard data layer and Augmented Reality (AR) in watershed control and outlines the guideline of a novel approach for the health-check of linear BS. We designed a mobile environmental monitoring system for smart maintenance of riverbanks by embedding the AR technology within a Geographical Information System (GIS). From the technological point of view, the system's architecture consists of a cloud-based service for data sharing, using a standard data layer, and of a mobile device provided with a GPS based AR engine for augmented data visualization. The proposed solution aims to ease the overall inspection process by reducing the time required to run a survey. Indeed, ordinary operational survey conditions are usually performed basing the fieldwork on just classical digitized maps. Our application proposes to enrich inspections by superimposing information on the device screen with the same point of view of the camera, providing an intuitive visualization of buffer strip location. This way, the inspection officer can quickly and dynamically access relevant information overlaying geographic features, comments and other contents in real time. The solution has been tested in fieldwork to prove at what extent this cutting-edge technology contributes to an effective monitoring over large territorial settings. The aim is to encourage officers, land managers and practitioners toward more effective monitoring and management practices.

  19. Aligning research assessment in the Humanities to the national Standard Evaluation Protocol Challenges and developments in the Dutch research landscape

    Energy Technology Data Exchange (ETDEWEB)

    Prins, A.; Spaapen, J.; Van Vree, F

    2016-07-01

    The purpose of this session is a debate about innovation in comprehensive methods for the assessment of humanities research. Input will come from preliminary outcomes of an ongoing project in the Netherlands to find adequate indicators for humanities research that will fit in the national Standard Evaluation Protocol. The project includes processes of ‘bottom up’ data collection (that is, with input coming from the research community) and discussion with Humanities researchers, investigating the specific characteristics of publication and communication cultures in the Humanities, and the prospects for the use of quantitative and qualitative indicators. (Author)

  20. Complications are reduced with a protocol to standardize timing of fixation based on response to resuscitation.

    Science.gov (United States)

    Vallier, Heather A; Moore, Timothy A; Como, John J; Wilczewski, Patricia A; Steinmetz, Michael P; Wagner, Karl G; Smith, Charles E; Wang, Xiao-Feng; Dolenc, Andrea J

    2015-10-01

    Our group developed a protocol, entitled Early Appropriate Care (EAC), to determine timing of definitive fracture fixation based on presence and severity of metabolic acidosis. We hypothesized that utilization of EAC would result in fewer complications than a historical cohort and that EAC patients with definitive fixation within 36 h would have fewer complications than those treated at a later time. Three hundred thirty-five patients with mean age 39.2 years and mean Injury Severity Score (ISS) 26.9 and 380 fractures of the femur (n = 173), pelvic ring (n = 71), acetabulum (n = 57), and/or spine (n = 79) were prospectively evaluated. The EAC protocol recommended definitive fixation within 36 h if lactate <4.0 mmol/L, pH ≥7.25, or base excess (BE) ≥-5.5 mmol/L. Complications including infections, sepsis, DVT, organ failure, pneumonia, acute respiratory distress syndrome (ARDS), and pulmonary embolism (PE) were identified and compared for early and delayed patients and with a historical cohort. All 335 patients achieved the desired level of resuscitation within 36 h of injury. Two hundred sixty-nine (80%) were treated within 36 h, and 66 had protocol violations, treated on a delayed basis, due to surgeon choice in 71%. Complications occurred in 16.3% of patients fixed within 36 h and in 33.3% of delayed patients (p = 0.0009). Hospital and ICU stays were shorter in the early group: 9.5 versus 17.3 days and 4.4 versus 11.6 days, respectively, both p < 0.0001. This group of patients when compared with a historical cohort of 1443 similar patients with 1745 fractures had fewer complications (16.3 versus 22.1%, p = 0.017) and shorter length of stay (LOS) (p = 0.018). Our EAC protocol recommends definitive fixation within 36 h in resuscitated patients. Early fixation was associated with fewer complications and shorter LOS. The EAC recommendations are safe and effective for the majority of severely injured patients with mechanically

  1. [Food Security in Europe: comparison between the "Hygiene Package" and the British Retail Consortium (BRC) & International Food Standard (IFS) protocols].

    Science.gov (United States)

    Stilo, A; Parisi, S; Delia, S; Anastasi, F; Bruno, G; Laganà, P

    2009-01-01

    The birth of Hygiene Package and of the Reg. CE no 2073/2005 in the food production field signalled a change in Italy. This process started in Italy in 1997 with the legislative decree no 155 on Self-control but in reality, it was implemented in the UK in 1990 with the promulgation of the Food Safety Act. This legal act was influenced by some basic rules corresponding to the application of HACCP standards. Since 1990 the British chains of distribution (Retailers) have involved all aspects of the food line in this type of responsibility. Due to this growing awareness for a need for greater regulation, a protocol, edited by British Retail Consortium was created in 1998. This protocol acted as a "stamp" of approval for food products and it is now known as the BRC Global Food Standard. In July 2008, this protocol became effective in its fifth version. After the birth of BRC, also French and German Retailers have established a standard practically equivalent and perhaps more pertinent to safety food, that is International Food Standard (IFS). The new approach is specific to the food field and strictly applies criteria which will ensure "safety, quality and legality" of food products, similarly to ISO 22000:2005 (mainly based on BRC & IFS past experiences). New standards aim to create a sort of green list with fully "proper and fit" Suppliers only, because of comprehensible exigencies of Retailers. It is expected, as we have shown, that Auditor authorities who are responsible for ensuring that inspections are now carried out like the Hygiene Package, will find these new standards useful. The advantages of streamlining this system is that it will allow enterprises to diligently enforce food safety practices without fear of upset or legal consequence, to improve the quality (HACCP) of management & traceability system; to restrict wastes, reprocessing and withdrawal of products. However some discordances about the interpretation of certain sub-field norms (e.g., water

  2. [Protocol for the study of bone tumours and standardization of pathology reports].

    Science.gov (United States)

    Machado, Isidro; Pozo, José Juan; Marcilla, David; Cruz, Julia; Tardío, Juan C; Astudillo, Aurora; Bagué, Sílvia

    Primary bone neoplasms represent a rare and heterogeneous group of mesenchymal tumours. The prevalence of benign and malignant tumours varies; the latter (sarcomas) account for less than 0.2% of all malignant tumours. Primary bone neoplasms are usually diagnosed and classified according to the criteria established and published by the World Health Organization (WHO 2013). These criteria are a result of advances in molecular pathology, which complements the histopathological diagnosis. Bone tumours should be diagnosed and treated in referral centers by a multidisciplinary team including pathologists, radiologists, orthopedic surgeons and oncologists. We analyzed different national and international protocols in order to provide a guide of recommendations for the improvement of pathological evaluation and management of bone tumours. We include specific recommendations for the pre-analytical, analytical, and post-analytical phases, as well as protocols for gross and microscopic pathology. Copyright © 2016 Sociedad Española de Anatomía Patológica. Publicado por Elsevier España, S.L.U. All rights reserved.

  3. Handbook of Carbon Offset Programs. Trading Systems, Funds, Protocols and Standards

    Energy Technology Data Exchange (ETDEWEB)

    Kollmuss, Anja; Lazarus, Michael; Lee, Carrie; Polycarp, Clifford (SEI-US (United States)); LeFranc, Maurice (US EPA (United States))

    2010-03-15

    Greenhouse gas (GHG) offsets have long been promoted as an important element of a comprehensive climate policy approach. Offset programs can reduce the overall cost of achieving a given emission goal by enabling emission reductions to occur where costs are lower. Offsets have the potential to deliver sustainability co-benefits, through technology development and transfer. They can also develop human and institutional capacity for reducing emissions in sectors and locations not included in a cap and trade or a mandatory government policy. However, offsets can pose a risk to the environmental integrity of climate actions, especially if issues surrounding additionality, permanence, leakage, quantification and verification are not adequately addressed. The challenge is to design offset programs and policies that can maximize their potential benefits while minimizing their potential risks. This handbook provides a systematic and comprehensive review of existing offset programs. It looks are what offsets are, how offset mechanisms function, and the successes and pitfalls they have encountered. Coverage includes offset programs across the full swath of applications including mandatory and voluntary systems, government regulated and private markets, carbon offset funds, and accounting and reporting protocols such as the WBCSD/WRI GHG Protocol and ISO 14064. Learning from the successes and failures of these programs will be essential to crafting effective climate policy. A reference for regulators, policy makers, business leaders and NGOs concerned with the design and operation of GHG offset programs world-wide

  4. Introduction of a standardized multimodality image protocol for navigation-guided surgery of suspected low-grade gliomas.

    Science.gov (United States)

    Mert, Aygül; Kiesel, Barbara; Wöhrer, Adelheid; Martínez-Moreno, Mauricio; Minchev, Georgi; Furtner, Julia; Knosp, Engelbert; Wolfsberger, Stefan; Widhalm, Georg

    2015-01-01

    OBJECT Surgery of suspected low-grade gliomas (LGGs) poses a special challenge for neurosurgeons due to their diffusely infiltrative growth and histopathological heterogeneity. Consequently, neuronavigation with multimodality imaging data, such as structural and metabolic data, fiber tracking, and 3D brain visualization, has been proposed to optimize surgery. However, currently no standardized protocol has been established for multimodality imaging data in modern glioma surgery. The aim of this study was therefore to define a specific protocol for multimodality imaging and navigation for suspected LGG. METHODS Fifty-one patients who underwent surgery for a diffusely infiltrating glioma with nonsignificant contrast enhancement on MRI and available multimodality imaging data were included. In the first 40 patients with glioma, the authors retrospectively reviewed the imaging data, including structural MRI (contrast-enhanced T1-weighted, T2-weighted, and FLAIR sequences), metabolic images derived from PET, or MR spectroscopy chemical shift imaging, fiber tracking, and 3D brain surface/vessel visualization, to define standardized image settings and specific indications for each imaging modality. The feasibility and surgical relevance of this new protocol was subsequently prospectively investigated during surgery with the assistance of an advanced electromagnetic navigation system in the remaining 11 patients. Furthermore, specific surgical outcome parameters, including the extent of resection, histological analysis of the metabolic hotspot, presence of a new postoperative neurological deficit, and intraoperative accuracy of 3D brain visualization models, were assessed in each of these patients. RESULTS After reviewing these first 40 cases of glioma, the authors defined a specific protocol with standardized image settings and specific indications that allows for optimal and simultaneous visualization of structural and metabolic data, fiber tracking, and 3D brain

  5. Is the standard compliance check protocol a valid measure of the accessibility of tobacco to underage smokers?

    Science.gov (United States)

    DiFranza, J.; Savageau, J.; Bouchard, J.

    2001-01-01

    OBJECTIVE—To determine if the standard compliance check protocol is a valid measure of the experience of underage smokers when purchasing tobacco in unfamiliar communities.
SETTING—160 tobacco outlets in eight Massachusetts communities where underage tobacco sales laws are vigorously enforced.
PROCEDURE—Completed purchase rates were compared between underage smokers who behaved normally and inexperienced non-smoking youths who were not allowed to lie or present proof of age (ID).
RESULTS—The "smoker protocol" increased the likelihood of a sale nearly sixfold over that for the non-smokers (odds ratio (OR) 5.7, 95% confidence interval (CI) 1.5 to 22). When the youths presented an ID with an underage birth date, the odds of a completed sale increased dramatically (OR 27, 95% CI 3.4 to 212). Clerks judged to be under 21 years of age were seven times more likely to make an illegal sale (OR 7.6, 95% CI 2.4 to 24.0).
CONCLUSIONS—Commonly used compliance check protocols are too artificial to reflect accurately the experience of underage smokers. The validity of compliance checks might be improved by having youths present ID, and by employing either tobacco users, or non-tobacco users who are sufficiently experienced to mimic the self confidence exhibited by tobacco users in this situation. Consideration should be given to prohibiting the sale of tobacco by individuals under 21 years of age.


Keywords: compliance check protocol; underage smokers PMID:11544386

  6. Psychometric Properties of a Standardized Observation Protocol to Quantify Pediatric Physical Therapy Actions.

    Science.gov (United States)

    Sonderer, Patrizia; Akhbari Ziegler, Schirin; Gressbach Oertle, Barbara; Meichtry, André; Hadders-Algra, Mijna

    2017-07-01

    Pediatric physical therapy (PPT) is characterized by heterogeneity. This blurs the evaluation of effective components of PPT. The Groningen Observation Protocol (GOP) was developed to quantify contents of PPT. This study assesses the reliability and completeness of the GOP. Sixty infant PPT sessions were video-taped. Two random samples of 10 videos were used to determine interrater and intrarater reliability using interclass correlation coefficients (ICCs) with 95% confidence intervals. Completeness of GOP 2.0 was based on 60 videos. Interrater reliability of quantifying PPT actions was excellent (ICC, 0.75-1.0) in 71% and sufficient to good (ICC, 0.4-0.74) in 24% of PPT actions. Intrarater reliability was excellent in 94% and sufficient to good in 6% of PPT actions. Completeness was good for greater than 90% of PPT actions. GOP 2.0 has good reliability and completeness. After appropriate training, it is a useful tool to quantify PPT for children with developmental disorders.

  7. Control protocol: the proposed new CERN standard access procedure to accelerator equipment

    International Nuclear Information System (INIS)

    Baribaud, G.; Barnett, I.; Benincasa, G.

    1992-01-01

    Control protocol provides a normalized access procedure for equipment of the same kind from a control system. Modelisation and the subsequent identification of functionalities with their parameters, variables and attributes have now been carried out at CERN for representative families of devices. ISO specifications, such as the ASN.1 metalanguage for data structure representation and MMS definitions and services have, to some extent, been introduced in the design for generality and compatibility with external world. The final product of this design is totally independent of the control systems and permits object oriented implementations in any controls frame. The present paper describes the different phases of the project with a short overview of the various implementations under development at CERN. (author)

  8. Recommended protocol for standardization in collecting and interpreting radiological environmental data

    International Nuclear Information System (INIS)

    Denham, D.H.; Kathren, R.L.

    1989-02-01

    Current reductions in ''allowable'' levels of radiation and radioactive materials in the environment and an increased public awareness of naturally occurring radioactive materials have reinforced the need for consistency in evaluating the radiological environment. A key concern is the identification and interpretation of environmental levels of radiation and radioactive materials resulting from nuclear facility operations. If these levels can be detected and their source(s) identified, then corrective actions can be taken to eliminate or greatly reduce the environmental impacts of the facility operations. In this paper we address the lack of definitive guidance necessary to determine incremental levels of significance (or insignificance), and we propose a series of protocols to achieve more consistent collection and interpretation of radiological environmental data. 8 refs

  9. Reproducibility of microbial mutagenicity assays. I. Tests with Salmonella typhimurium and Escherichia coli using a standardized protocol

    International Nuclear Information System (INIS)

    Dunkel, V.C.; Zeiger, E.; Brusick, D.; McCoy, E.; McGregor, D.; Mortelmans, K.; Rosenkranz, H.S.; Simmon, V.F.

    1984-01-01

    The Salmonella/microsome test developed by Ames and his coworkers has been widely used in the evaluation of chemicals for genotoxic potential. Although the value of this assay is well recognized, there have been no comprehensive studies on the interlaboratory reproducibility of the method using a standardized protocol. A program was therefore initiated to compare the results obtained in four laboratories from testing a series of coded mutagens and nonmutagens using a standardized protocol. Additional objectives of this study were to compare male Fisher 344 rat, B6C3F1 mouse, and Syrian hamster liver S-9 preparations for the activation of chemicals; to compare Aroclor 1254-induced liver S-9 from all three species with the corresponding non-induced liver S-9's; and to compare the response of Escherichia coli WP-2 uvrA with the Salmonella typhimurium tester strains recommended by Ames. Since a primary use of in vitro microbial mutagenesis tests is the identification of potential carcinogens by their mutagenicity, the authors decided to compare the animal species and strains used by the National Cancer Institute/National Toxicology Program (NCI/NTP) for animal carcinogenicity studies

  10. Metabolomics Workbench: An international repository for metabolomics data and metadata, metabolite standards, protocols, tutorials and training, and analysis tools.

    Science.gov (United States)

    Sud, Manish; Fahy, Eoin; Cotter, Dawn; Azam, Kenan; Vadivelu, Ilango; Burant, Charles; Edison, Arthur; Fiehn, Oliver; Higashi, Richard; Nair, K Sreekumaran; Sumner, Susan; Subramaniam, Shankar

    2016-01-04

    The Metabolomics Workbench, available at www.metabolomicsworkbench.org, is a public repository for metabolomics metadata and experimental data spanning various species and experimental platforms, metabolite standards, metabolite structures, protocols, tutorials, and training material and other educational resources. It provides a computational platform to integrate, analyze, track, deposit and disseminate large volumes of heterogeneous data from a wide variety of metabolomics studies including mass spectrometry (MS) and nuclear magnetic resonance spectrometry (NMR) data spanning over 20 different species covering all the major taxonomic categories including humans and other mammals, plants, insects, invertebrates and microorganisms. Additionally, a number of protocols are provided for a range of metabolite classes, sample types, and both MS and NMR-based studies, along with a metabolite structure database. The metabolites characterized in the studies available on the Metabolomics Workbench are linked to chemical structures in the metabolite structure database to facilitate comparative analysis across studies. The Metabolomics Workbench, part of the data coordinating effort of the National Institute of Health (NIH) Common Fund's Metabolomics Program, provides data from the Common Fund's Metabolomics Resource Cores, metabolite standards, and analysis tools to the wider metabolomics community and seeks data depositions from metabolomics researchers across the world. © The Author(s) 2015. Published by Oxford University Press on behalf of Nucleic Acids Research.

  11. 75 FR 20901 - Standards for Business Practices and Communication Protocols for Public Utilities

    Science.gov (United States)

    2010-04-22

    ... verify demand response products in wholesale markets administered by the ISOs and RTOs.\\13\\ \\13\\ Phase I... contends that the ISOs and RTOs are in a better position to develop these standards, due to regional... providers, ISOs, RTOs, public utilities and trade groups. 27. The continued cooperation and efforts of all...

  12. A standardized conjugation protocol to asses antibiotic resistance transfer between lactococcal species

    DEFF Research Database (Denmark)

    Lampkowska, Joanna; Feld, Louise; Monaghan, Aine

    2008-01-01

    Optimal conditions and a standardized method for conjugation between two model lactococcal strains, Lactococcus lactis SH4174 (pAM beta 1-containing, erythromycin resistant donor) and L. lactis Bu2-60 (plasmid-free, erythromycin sensitive recipient), were developed and tested in a inter-laborator...

  13. A standardized conjugation protocol to assess antibiotic resistance transfer between lactococcal species

    NARCIS (Netherlands)

    Lampkowska, J.; Feld, L.; Monaghan, A.; Toomey, N.; Schjørring, S.; Jacobsen, B.; Voet, van der H.; Andersen, S.R.; Bolton, D.; Aarts, H.J.M.; Krogfelt, K.A.; Wilcks, A.; Bardowski, J.K.

    2008-01-01

    Optimal conditions and a standardized method for conjugation between two model lactococcal strains, Lactococcus lactis SH4174 (pAMbeta1-containing, erythromycin resistant donor) and L. lactis Bu2-60 (plasmid-free, erythromycin sensitive recipient), were developed and tested in a inter-laboratory

  14. Spray Drift Reduction Evaluations of Spray Nozzles Using a Standardized Testing Protocol

    Science.gov (United States)

    2010-07-01

    Drop Size Characteristics in a Spray Using Optical Nonimaging Light-Scattering Instruments,” Annual Book of ASTM Standards, Vol. 14-02, ASTM...Test Method for Determining Liquid Drop Size Characteristics in a Spray Using Optical Non- imaging Light-Scattering Instruments 22. AGDISP Model

  15. Protocol - realist and meta-narrative evidence synthesis: Evolving Standards (RAMESES

    Directory of Open Access Journals (Sweden)

    Westhorp Gill

    2011-08-01

    Full Text Available Abstract Background There is growing interest in theory-driven, qualitative and mixed-method approaches to systematic review as an alternative to (or to extend and supplement conventional Cochrane-style reviews. These approaches offer the potential to expand the knowledge base in policy-relevant areas - for example by explaining the success, failure or mixed fortunes of complex interventions. However, the quality of such reviews can be difficult to assess. This study aims to produce methodological guidance, publication standards and training resources for those seeking to use the realist and/or meta-narrative approach to systematic review. Methods/design We will: [a] collate and summarise existing literature on the principles of good practice in realist and meta-narrative systematic review; [b] consider the extent to which these principles have been followed by published and in-progress reviews, thereby identifying how rigour may be lost and how existing methods could be improved; [c] using an online Delphi method with an interdisciplinary panel of experts from academia and policy, produce a draft set of methodological steps and publication standards; [d] produce training materials with learning outcomes linked to these steps; [e] pilot these standards and training materials prospectively on real reviews-in-progress, capturing methodological and other challenges as they arise; [f] synthesise expert input, evidence review and real-time problem analysis into more definitive guidance and standards; [g] disseminate outputs to audiences in academia and policy. The outputs of the study will be threefold: 1. Quality standards and methodological guidance for realist and meta-narrative reviews for use by researchers, research sponsors, students and supervisors 2. A 'RAMESES' (Realist and Meta-review Evidence Synthesis: Evolving Standards statement (comparable to CONSORT or PRISMA of publication standards for such reviews, published in an open

  16. A Review of Offset Programs: Trading Systems, Funds, Protocols, Standards and Retailers

    Energy Technology Data Exchange (ETDEWEB)

    Kollmuss, Anja; Lazarus, Michael; Lee, Carrie; Polycarp, Clifford

    2008-11-15

    Carbon or greenhouse gas (GHG) offsets have long been promoted as an important element of a comprehensive climate policy approach. Offset programs can reduce the overall cost of achieving a given emission goal by enabling emission reductions to occur where costs are lower. Furthermore, offsets have the potential to deliver sustainability co-benefits, spurred through technology development and transfer, and to develop human and institutional capacity for reducing emissions in sectors and locations not included in a cap and trade or a mandatory government policy. However, offsets can pose a risk to the environmental integrity of climate actions, especially if issues surrounding additionality, permanence, leakage, quantification and verification are not adequately addressed. The challenge for policymakers is clear: to design offset programs and policies that can maximize their potential benefits while minimizing their potential risks. The goal of this review is to provide an up-to-date analysis and synthesis of the most influential offset programs and activities, to reflect on lessons learned, and thus to inform participants and designers of current and future offset programs. Our intention is to periodically update this review to stay abreast of ongoing developments, and to develop a website portal to make this information more accessible. This version targets programs that meet one or more of the following criteria: - a significant volume of credit transactions occurring or anticipated; - an established set of rules or protocols - path-breaking, novel or otherwise notable initiatives or important lessons learned

  17. Standard protocol for demographic and epidemiological survey to be carried out for nuclear facilities

    Energy Technology Data Exchange (ETDEWEB)

    Joshi, M L; Datta, D; Singh, Jitendra; Sardhi, I V; Verma, P C [Health Physics Division, Bhabha Atomic Research Centre, Mumbai (India)

    2007-11-15

    This document presents the standard procedures for conducting demographic and epidemiological studies for nuclear facilities. These studies are required to be carried out to prepare baseline data, the impact of the facility and the risk factors for the population residing in the vicinity of facility. This document includes the basic elements of these type surveys, their methodology and statistical analysis of the data collected during demographic and epidemiological surveillance. (author)

  18. Standard protocol for demographic and epidemiological survey to be carried out for nuclear facilities

    International Nuclear Information System (INIS)

    Joshi, M.L.; Datta, D.; Singh, Jitendra; Sardhi, I.V.; Verma, P.C.

    2007-11-01

    This document presents the standard procedures for conducting demographic and epidemiological studies for nuclear facilities. These studies are required to be carried out to prepare baseline data, the impact of the facility and the risk factors for the population residing in the vicinity of facility. This document includes the basic elements of these type surveys, their methodology and statistical analysis of the data collected during demographic and epidemiological surveillance. (author)

  19. Early Appropriate Care: A Protocol to Standardize Resuscitation Assessment and to Expedite Fracture Care Reduces Hospital Stay and Enhances Revenue.

    Science.gov (United States)

    Vallier, Heather A; Dolenc, Andrea J; Moore, Timothy A

    2016-06-01

    We hypothesized that a standardized protocol for fracture care would enhance revenue by reducing complications and length of stay. Prospective consecutive series. Level 1 trauma center. Two hundread and fifty-three adult patients with a mean age of 40.7 years and mean Injury Severity Score of 26.0. Femur, pelvis, or spine fractures treated surgically. Hospital and professional charges and collections were analyzed. Fixation was defined as early (<36 hours) or delayed. Complications and hospital stay were recorded. Mean charges were US $180,145 with a mean of US $66,871 collected (37%). The revenue multiplier was US $59,882/$6989 (8.57), indicating hospital collection of US $8.57 for every professional dollar, less than half of which went to orthopaedic surgeons. Delayed fracture care was associated with more intensive care unit (4.5 vs. 9.4) and total hospital days (9.4 vs. 15.3), with mean loss of actual revenue US $6380/patient delayed (n = 47), because of the costs of longer length of stay. Complications were associated with the highest expenses: mean of US $291,846 charges and US $101,005 collections, with facility collections decreased by 5.1%. An uncomplicated course of care was associated with the most favorable total collections: (US $60,017/$158,454 = 38%) and the shortest mean stay (8.7 days). Facility collections were nearly 9 times more than professional collections. Delayed fixation was associated with more complications, and facility collections decreased 5% with a complication. Furthermore, delayed fixation was associated with longer hospital stay, accounting for US $300K more in actual costs during the study. A standardized protocol to expedite definitive fixation enhances the profitability of the trauma service line. Economic Level IV. See Instructions for Authors for a complete description of levels of evidence.

  20. Towards a standard protocol for antimony intralesional infiltration technique for cutaneous leishmaniasis treatment

    Directory of Open Access Journals (Sweden)

    Rosiana Estéfane da Silva

    Full Text Available BACKGROUND Despite its recognised toxicity, antimonial therapy continues to be the first-line drug for cutaneous leishmaniasis (CL treatment. Intralesional administration of meglumine antimoniate (MA represents an alternative that could reduce the systemic absorption of the drug and its side effects. OBJECTIVES This study aims to validate the standard operational procedure (SOP for the intralesional infiltration of MA for CL therapy as the first step before the assessment of efficacy and safety related to the procedure. METHODS The SOP was created based on 21 trials retrieved from the literature, direct monitoring of the procedure and consultation with experts. This script was submitted to a formal computer-aided inspection to identify readability, clarity, omission, redundancy and unnecessary information (content validation. For criterion and construct validations, the influence of critical condition changes (compliance with the instructions and professional experience on outcome conformity (saturation status achievement, tolerability (pain referred and safety (bleeding were assessed. FINDINGS The median procedure length was 12 minutes and in 72% of them, patients classified the pain as mild. The bleeding was also classified as mild in 96.6% of the procedures. Full compliance with the SOP was observed in 66% of infiltrations. Despite this, in 100% of the inspected procedures, lesion saturation was observed at the end of infiltration, which means that it tolerates some degree of modification in its execution (robustness without prejudice to the result. CONCLUSIONS The procedure is reproducible and can be used by professionals without previous training with high success and safety rates.

  1. Towards a standard protocol for antimony intralesional infiltration technique for cutaneous leishmaniasis treatment.

    Science.gov (United States)

    Silva, Rosiana Estéfane da; Carvalho, Janaína de Pina; Ramalho, Dario Brock; Senna, Maria Camilo Ribeiro De; Moreira, Hugo Silva Assis; Rabello, Ana; Cota, Erika; Cota, Gláucia

    2018-02-01

    BACKGROUND Despite its recognised toxicity, antimonial therapy continues to be the first-line drug for cutaneous leishmaniasis (CL) treatment. Intralesional administration of meglumine antimoniate (MA) represents an alternative that could reduce the systemic absorption of the drug and its side effects. OBJECTIVES This study aims to validate the standard operational procedure (SOP) for the intralesional infiltration of MA for CL therapy as the first step before the assessment of efficacy and safety related to the procedure. METHODS The SOP was created based on 21 trials retrieved from the literature, direct monitoring of the procedure and consultation with experts. This script was submitted to a formal computer-aided inspection to identify readability, clarity, omission, redundancy and unnecessary information (content validation). For criterion and construct validations, the influence of critical condition changes (compliance with the instructions and professional experience) on outcome conformity (saturation status achievement), tolerability (pain referred) and safety (bleeding) were assessed. FINDINGS The median procedure length was 12 minutes and in 72% of them, patients classified the pain as mild. The bleeding was also classified as mild in 96.6% of the procedures. Full compliance with the SOP was observed in 66% of infiltrations. Despite this, in 100% of the inspected procedures, lesion saturation was observed at the end of infiltration, which means that it tolerates some degree of modification in its execution (robustness) without prejudice to the result. CONCLUSIONS The procedure is reproducible and can be used by professionals without previous training with high success and safety rates.

  2. The international protocol for the dosimetry of external radiotherapy beams based on standards of absorbed dose to water

    International Nuclear Information System (INIS)

    Andreo, P.

    2001-01-01

    An International Code of Practice (CoP, or dosimetry protocol) for external beam radiotherapy dosimetry based on standards of absorbed dose to water has been published by the IAEA on behalf of IAEA, WHO, PAHO and ESTRO. The CoP provides a systematic and internationally unified approach for the determination of the absorbed dose to water in reference conditions with radiotherapy beams. The development of absorbed-dose-to-water standards for high-energy photons and electrons offers the possibility of reducing the uncertainty in the dosimetry of radiotherapy beams. Many laboratories already provide calibrations at the radiation quality of 60Co gamma-rays and some have extended calibrations to high-energy photon and electron beams. The dosimetry of kilovoltage x-rays, as well as that of proton and ion beams can also be based on these standards. Thus, a coherent dosimetry system based on the same formalism is achieved for practically all radiotherapy beams. The practical use of the CoP as simple. The document is formed by a set of different CoPs for each radiation type, which include detailed procedures and worksheets. All CoPs are based on ND,w chamber calibrations at a reference beam quality Qo, together with radiation beam quality correction factors kQ preferably measured directly for the user's chamber in a standards laboratory. Calculated values of kQ are provided together with their uncertainty estimates. Beam quality specifiers are 60Co, TPR20,10 (high-energy photons), R50 (electrons), HVL and kV (x-rays) and Rres (protons and ions) [es

  3. Retinal nerve fiber layer assessment by scanning laser polarimetry and standardized photography

    NARCIS (Netherlands)

    Niessen, A. G.; van den Berg, T. J.; Langerhorst, C. T.; Greve, E. L.

    1996-01-01

    To determine whether, in a clinical setting, scanning laser polarimetry and retinal nerve fiber layer photography provide equivalent information on the retinal nerve fiber layer. We prospectively studied 60 patients with glaucoma or ocular hypertension and 24 healthy subjects. With scanning laser

  4. Thromboelastometry versus standard coagulation tests versus restrictive protocol to guide blood transfusion prior to central venous catheterization in cirrhosis: study protocol for a randomized controlled trial.

    Science.gov (United States)

    Rocha, Leonardo Lima; Pessoa, Camila Menezes Souza; Neto, Ary Serpa; do Prado, Rogerio Ruscitto; Silva, Eliezer; de Almeida, Marcio Dias; Correa, Thiago Domingos

    2017-02-27

    Liver failure patients have traditionally been empirically transfused prior to invasive procedures. Blood transfusion is associated with immunologic and nonimmunologic reactions, increased risk of adverse outcomes and high costs. Scientific evidence supporting empirical transfusion is lacking, and the best approach for blood transfusion prior to invasive procedures in cirrhotic patients has not been established so far. The aim of this study is to compare three transfusion strategies (routine coagulation test-guided - ordinary or restrictive, or thromboelastometry-guided) prior to central venous catheterization in critically ill patients with cirrhosis. Design and setting: a double-blinded, parallel-group, single-center, randomized controlled clinical trial in a tertiary private hospital in São Paulo, Brazil. adults (aged 18 years or older) admitted to the intensive care unit with cirrhosis and an indication for central venous line insertion. Patients will be randomly assigned to three groups for blood transfusion strategy prior to central venous catheterization: standard coagulation tests-based, thromboelastometry-based, or restrictive. The primary efficacy endpoint will be the proportion of patients transfused with any blood product prior to central venous catheterization. The primary safety endpoint will be the incidence of major bleeding. Secondary endpoints will be the proportion of transfusion of fresh frozen plasma, platelets and cryoprecipitate; infused volume of blood products; hemoglobin and hematocrit before and after the procedure; intensive care unit and hospital length of stay; 28-day and hospital mortality; incidence of minor bleeding; transfusion-related adverse reactions; and cost analysis. This study will evaluate three strategies to guide blood transfusion prior to central venous line placement in severely ill patients with cirrhosis. We hypothesized that thromboelastometry-based and/or restrictive protocols are safe and would significantly

  5. Deficiency of standard effective-medium approximation for ellipsometry of layers of nanoparticles

    Czech Academy of Sciences Publication Activity Database

    Bortchagovsky, E. G.; Dejneka, Alexandr; Jastrabík, Lubomír; Lozovski, V.Z.; Mishakova, T.O.

    2015-01-01

    Roč. 2015, Nov (2015), s. 602848 ISSN 1687-4110 Institutional support: RVO:68378271 Keywords : ellipsometry * layers of nanoparticles * Green function in ?-? representation Subject RIV: BM - Solid Matter Physics ; Magnetism Impact factor: 1.758, year: 2015

  6. Matrix-assisted laser desorption/ionization-time of flight mass spectrometry: protocol standardization and database expansion for rapid identification of clinically important molds.

    Science.gov (United States)

    Paul, Saikat; Singh, Pankaj; Rudramurthy, Shivaprakash M; Chakrabarti, Arunaloke; Ghosh, Anup K

    2017-12-01

    To standardize the matrix-assisted laser desorption ionization-time of flight mass spectrometry protocols and expansion of existing Bruker Biotyper database for mold identification. Four different sample preparation methods (protocol A, B, C and D) were evaluated. On analyzing each protein extraction method, reliable identification and best log scores were achieved through protocol D. The same protocol was used to identify 153 clinical isolates. Of these 153, 123 (80.3%) were accurately identified by using existing database and remaining 30 (19.7%) were not identified due to unavailability in database. On inclusion of missing main spectrum profile in existing database, all 153 isolates were identified. Matrix-assisted laser desorption ionization-time of flight mass spectrometry can be used for routine identification of clinically important molds.

  7. Laparoscopic colorectal surgery in learning curve: Role of implementation of a standardized technique and recovery protocol. A cohort study

    Science.gov (United States)

    Luglio, Gaetano; De Palma, Giovanni Domenico; Tarquini, Rachele; Giglio, Mariano Cesare; Sollazzo, Viviana; Esposito, Emanuela; Spadarella, Emanuela; Peltrini, Roberto; Liccardo, Filomena; Bucci, Luigi

    2015-01-01

    Background Despite the proven benefits, laparoscopic colorectal surgery is still under utilized among surgeons. A steep learning is one of the causes of its limited adoption. Aim of the study is to determine the feasibility and morbidity rate after laparoscopic colorectal surgery in a single institution, “learning curve” experience, implementing a well standardized operative technique and recovery protocol. Methods The first 50 patients treated laparoscopically were included. All the procedures were performed by a trainee surgeon, supervised by a consultant surgeon, according to the principle of complete mesocolic excision with central vascular ligation or TME. Patients underwent a fast track recovery programme. Recovery parameters, short-term outcomes, morbidity and mortality have been assessed. Results Type of resections: 20 left side resections, 8 right side resections, 14 low anterior resection/TME, 5 total colectomy and IRA, 3 total panproctocolectomy and pouch. Mean operative time: 227 min; mean number of lymph-nodes: 18.7. Conversion rate: 8%. Mean time to flatus: 1.3 days; Mean time to solid stool: 2.3 days. Mean length of hospital stay: 7.2 days. Overall morbidity: 24%; major morbidity (Dindo–Clavien III): 4%. No anastomotic leak, no mortality, no 30-days readmission. Conclusion Proper laparoscopic colorectal surgery is safe and leads to excellent results in terms of recovery and short term outcomes, even in a learning curve setting. Key factors for better outcomes and shortening the learning curve seem to be the adoption of a standardized technique and training model along with the strict supervision of an expert colorectal surgeon. PMID:25859386

  8. Accelerated rehabilitation compared with a standard protocol after distal radial fractures treated with volar open reduction and internal fixation: a prospective, randomized, controlled study.

    Science.gov (United States)

    Brehmer, Jess L; Husband, Jeffrey B

    2014-10-01

    There are relatively few studies in the literature that specifically evaluate accelerated rehabilitation protocols for distal radial fractures treated with open reduction and internal fixation (ORIF). The purpose of this study was to compare the early postoperative outcomes (at zero to twelve weeks postoperatively) of patients enrolled in an accelerated rehabilitation protocol with those of patients enrolled in a standard rehabilitation protocol following ORIF for a distal radial fracture. We hypothesized that patients with accelerated rehabilitation after volar ORIF for a distal radial fracture would have an earlier return to function compared with patients who followed a standard protocol. From November 2007 to November 2010, eighty-one patients with an unstable distal radial fracture were prospectively randomized to follow either an accelerated or a standard rehabilitation protocol after undergoing ORIF with a volar plate for a distal radial fracture. Both groups began with gentle active range of motion at three to five days postoperatively. At two weeks, the accelerated group initiated wrist/forearm passive range of motion and strengthening exercises, whereas the standard group initiated passive range of motion and strengthening at six weeks postoperatively. Patients were assessed at three to five days, two weeks, three weeks, four weeks, six weeks, eight weeks, twelve weeks, and six months postoperatively. Outcomes included Disabilities of the Arm, Shoulder and Hand (DASH) scores (primary outcome) and measurements of wrist flexion/extension, supination, pronation, grip strength, and palmar pinch. The patients in the accelerated group had better mobility, strength, and DASH scores at the early postoperative time points (zero to eight weeks postoperatively) compared with the patients in the standard rehabilitation group. The difference between the groups was both clinically relevant and statistically significant. Patients who follow an accelerated rehabilitation

  9. New Normative Database of Inner Macular Layer Thickness Measured by Spectralis OCT Used as Reference Standard for Glaucoma Detection.

    Science.gov (United States)

    Nieves-Moreno, María; Martínez-de-la-Casa, José M; Bambo, María P; Morales-Fernández, Laura; Van Keer, Karel; Vandewalle, Evelien; Stalmans, Ingeborg; García-Feijoó, Julián

    2018-02-01

    This study examines the capacity to detect glaucoma of inner macular layer thickness measured by spectral-domain optical coherence tomography (SD-OCT) using a new normative database as the reference standard. Participants ( N = 148) were recruited from Leuven (Belgium) and Zaragoza (Spain): 74 patients with early/moderate glaucoma and 74 age-matched healthy controls. One eye was randomly selected for a macular scan using the Spectralis SD-OCT. The variables measured with the instrument's segmentation software were: macular nerve fiber layer (mRNFL), ganglion cell layer (GCL), and inner plexiform layer (IPL) volume and thickness along with circumpapillary RNFL thickness (cpRNFL). The new normative database of macular variables was used to define the cutoff of normality as the fifth percentile by age group. Sensitivity, specificity, and area under the receiver operating characteristic curve (AUROC) of each macular measurement and of cpRNFL were used to distinguish between patients and controls. Overall sensitivity and specificity to detect early-moderate glaucoma were 42.2% and 88.9% for mRNFL, 42.4% and 95.6% for GCL, 42.2% and 94.5% for IPL, and 53% and 94.6% for RNFL, respectively. The best macular variable to discriminate between the two groups of subjects was outer temporal GCL thickness as indicated by an AUROC of 0.903. This variable performed similarly to mean cpRNFL thickness (AUROC = 0.845; P = 0.29). Using our normative database as reference, the diagnostic power of inner macular layer thickness proved comparable to that of peripapillary RNFL thickness. Spectralis SD-OCT, cpRNFL thickness, and individual macular inner layer thicknesses show comparable diagnostic capacity for glaucoma and RNFL, GCL, and IPL thickness may be useful as an alternative diagnostic test when the measure of cpRNFL shows artifacts.

  10. A collaborative study on a Nordic standard protocol for detection and enumeration of thermotolerant Campylobacter in food (NMKL 119, 3. Ed., 2007)

    DEFF Research Database (Denmark)

    Rosenquist, Hanne; Bengtsson, Anja; Hansen, Tina Beck

    2007-01-01

    A Nordic standard protocol for detection and enumeration of thermotolerant Campylobacter in food has been elaborated (NMKL 119, 3. Ed., 2007). Performance and precision characteristics of this protocol were evaluated in a collaborative study with participation of 14 laboratories from seven European...... jejuni (SLV-542). Expected concentrations (95% C.I.) (cfu g(-1) or ml(-1)) of both strains in matrices were 0.6-1.4 and 23-60 for qualitative detection, and 0.6-1.4; 23-60; and 420-1200 for semi-quantitative detection. For quantitative determination, the expected concentrations of C. jejuni/C. coli were...

  11. Step-height standards based on the rapid formation of monolayer steps on the surface of layered crystals

    Energy Technology Data Exchange (ETDEWEB)

    Komonov, A.I. [Rzhanov Institute of Semiconductor Physics, Siberian Branch of the Russian Academy of Sciences (ISP SBRAS), pr. Lavrentieva 13, Novosibirsk 630090 (Russian Federation); Prinz, V.Ya., E-mail: prinz@isp.nsc.ru [Rzhanov Institute of Semiconductor Physics, Siberian Branch of the Russian Academy of Sciences (ISP SBRAS), pr. Lavrentieva 13, Novosibirsk 630090 (Russian Federation); Seleznev, V.A. [Rzhanov Institute of Semiconductor Physics, Siberian Branch of the Russian Academy of Sciences (ISP SBRAS), pr. Lavrentieva 13, Novosibirsk 630090 (Russian Federation); Kokh, K.A. [Sobolev Institute of Geology and Mineralogy, Siberian Branch of the Russian Academy of Sciences (IGM SB RAS), pr. Koptyuga 3, Novosibirsk 630090 (Russian Federation); Shlegel, V.N. [Nikolaev Institute of Inorganic Chemistry, Siberian Branch of the Russian Academy of Sciences (NIIC SB RAS), pr. Lavrentieva 3, Novosibirsk 630090 (Russian Federation)

    2017-07-15

    Highlights: • Easily reproducible step-height standard for SPM calibrations was proposed. • Step-height standard is monolayer steps on the surface of layered single crystal. • Long-term change in surface morphology of Bi{sub 2}Se{sub 3} and ZnWO{sub 4} was investigated. • Conducting surface of Bi{sub 2}Se{sub 3} crystals appropriate for calibrating STM. • Ability of robust SPM calibrations under ambient conditions were demonstrated. - Abstract: Metrology is essential for nanotechnology, especially for structures and devices with feature sizes going down to nm. Scanning probe microscopes (SPMs) permits measurement of nanometer- and subnanometer-scale objects. Accuracy of size measurements performed using SPMs is largely defined by the accuracy of used calibration measures. In the present publication, we demonstrate that height standards of monolayer step (∼1 and ∼0.6 nm) can be easily prepared by cleaving Bi{sub 2}Se{sub 3} and ZnWO{sub 4} layered single crystals. It was shown that the conducting surface of Bi{sub 2}Se{sub 3} crystals offers height standard appropriate for calibrating STMs and for testing conductive SPM probes. Our AFM study of the morphology of freshly cleaved (0001) Bi{sub 2}Se{sub 3} surfaces proved that such surfaces remained atomically smooth during a period of at least half a year. The (010) surfaces of ZnWO{sub 4} crystals remained atomically smooth during one day, but already two days later an additional nanorelief of amplitude ∼0.3 nm appeared on those surfaces. This relief, however, did not further grow in height, and it did not hamper the calibration. Simplicity and the possibility of rapid fabrication of the step-height standards, as well as their high stability, make these standards available for a great, permanently growing number of users involved in 3D printing activities.

  12. Quality of dispatch-assisted cardiopulmonary resuscitation by lay rescuers following a standard protocol in Japan: an observational simulation study.

    Science.gov (United States)

    Asai, Hideki; Fukushima, Hidetada; Bolstad, Francesco; Okuchi, Kazuo

    2018-04-01

    Bystander cardiopulmonary resuscitation (CPR) is essential for improving the outcomes of sudden cardiac arrest patients. It has been reported that dispatch-assisted CPR (DACPR) accounts for more than half of the incidence of CPR undertaken by bystanders. Its quality, however, can be suboptimal. We aimed to measure the quality of DACPR using a simulation study. We recruited laypersons at a shopping mall and measured the quality of CPR carried out in our simulation. Dispatchers provided instruction in accordance with the standard DACPR protocol in Japan. Twenty-three laypersons (13 with CPR training experience within the past 2 years and 10 with no training experience) participated in this study. The median chest compression rate and depth were 106/min and 33 mm, respectively. The median time interval from placing the 119 call to the start of chest compressions was 119 s. No significant difference was found between the groups with and without training experience. However, subjects with training experience more frequently placed their hands correctly on the manikin (84.6% versus 40.0%; P = 0.026). Twelve participants (52.2%, seven in trained and five in untrained group) interrupted chest compressions for 3-18 s, because dispatchers asked if the patient started breathing or moving. This current simulation study showed that the quality of DACPR carried out by lay rescuers can be less than optimal in terms of depth, hand placement, and minimization of pauses. Further studies are required to explore better DACPR instruction methods to help lay rescuers perform CPR with optimal quality.

  13. Fast and easy protocol for the purification of recombinant S-layer protein for synthetic biology applications

    KAUST Repository

    Norville, Julie E.; Kelly, Deborah F.; Knight, Thomas F.; Belcher, Angela M.; Walz, Thomas

    2011-01-01

    A goal of synthetic biology is to make biological systems easier to engineer. One of the aims is to design, with nanometer-scale precision, biomaterials with well-defined properties. The surface-layer protein SbpA forms 2D arrays naturally

  14. Effectiveness of a Rapid Lumbar Spine MRI Protocol Using 3D T2-Weighted SPACE Imaging Versus a Standard Protocol for Evaluation of Degenerative Changes of the Lumbar Spine.

    Science.gov (United States)

    Sayah, Anousheh; Jay, Ann K; Toaff, Jacob S; Makariou, Erini V; Berkowitz, Frank

    2016-09-01

    Reducing lumbar spine MRI scanning time while retaining diagnostic accuracy can benefit patients and reduce health care costs. This study compares the effectiveness of a rapid lumbar MRI protocol using 3D T2-weighted sampling perfection with application-optimized contrast with different flip-angle evolutions (SPACE) sequences with a standard MRI protocol for evaluation of lumbar spondylosis. Two hundred fifty consecutive unenhanced lumbar MRI examinations performed at 1.5 T were retrospectively reviewed. Full, rapid, and complete versions of each examination were interpreted for spondylotic changes at each lumbar level, including herniations and neural compromise. The full examination consisted of sagittal T1-weighted, T2-weighted turbo spin-echo (TSE), and STIR sequences; and axial T1- and T2-weighted TSE sequences (time, 18 minutes 40 seconds). The rapid examination consisted of sagittal T1- and T2-weighted SPACE sequences, with axial SPACE reformations (time, 8 minutes 46 seconds). The complete examination consisted of the full examination plus the T2-weighted SPACE sequence. Sensitivities and specificities of the full and rapid examinations were calculated using the complete study as the reference standard. The rapid and full studies had sensitivities of 76.0% and 69.3%, with specificities of 97.2% and 97.9%, respectively, for all degenerative processes. Rapid and full sensitivities were 68.7% and 66.3% for disk herniation, 85.2% and 81.5% for canal compromise, 82.9% and 69.1% for lateral recess compromise, and 76.9% and 69.7% for foraminal compromise, respectively. Isotropic SPACE T2-weighted imaging provides high-quality imaging of lumbar spondylosis, with multiplanar reformatting capability. Our SPACE-based rapid protocol had sensitivities and specificities for herniations and neural compromise comparable to those of the protocol without SPACE. This protocol fits within a 15-minute slot, potentially reducing costs and discomfort for a large subgroup of

  15. Effectiveness of various irrigation activation protocols and the self-adjusting file system on smear layer and debris removal.

    Science.gov (United States)

    Çapar, İsmail Davut; Aydinbelge, Hale Ari

    2014-01-01

    The purpose of the present study is to evaluate smear layer generation and residual debris after using self-adjusting file (SAF) or rotary instrumentation and to compare the debris and smear layer removal efficacy of the SAF cleaning/shaping irrigation system against final agitation techniques. One hundred and eight maxillary lateral incisor teeth were randomly divided into nine experimental groups (n = 12), and root canals were prepared using ProTaper Universal rotary files, with the exception of the SAF instrumentation group. During instrumentation, root canals were irrigated with a total of 16 mL of 5% NaOCl. For final irrigation, rotary-instrumented groups were irrigated with 10 mL of 17% EDTA and 10 mL of 5% NaOCl using different irrigation agitation regimens (syringe irrigation with needles, NaviTip FX, manual dynamic irrigation, CanalBrush, EndoActivator, EndoVac, passive ultrasonic irrigation (PUI), and SAF irrigation). In the SAF instrumentation group, root canals were instrumented for 4 min at a rate of 4 mL/min with 5% NaOCl and received a final flush with same as syringe irrigation with needles. The surface of the root dentin was observed using a scanning electron microscope. The SAF instrumentation group generated less smear layer and yielded cleaner canals compared to rotary instrumentation. The EndoActivator, EndoVac, PUI, and SAF irrigation groups increased the efficacy of irrigating solutions on the smear layer and debris removal. The SAF instrumentation yielded cleaner canal walls when compared to rotary instrumentation. None of the techniques completely removed the smear layer from the root canal walls. © 2014 Wiley Periodicals, Inc.

  16. FPGA based data-flow injection module at 10 Gbit/s reading data from network exported storage and using standard protocols

    International Nuclear Information System (INIS)

    Lemouzy, B; Garnier, J-C; Neufeld, N

    2011-01-01

    The goal of the LHCb readout upgrade is to accelerate the DAQ to 40 MHz. Such a DAQ system will certainly employ 10 Gigabit or similar technologies and might also need new networking protocols such as a customized, light-weight TCP or more specialized protocols. A test module is being implemented to be integrated in the existing LHCb infrastructure. It is a multiple 10-Gigabit traffic generator, driven by a Stratix IV FPGA, and flexible enough to generate LHCb's raw data packets. Traffic data are either internally generated or read from external storage via the network. We have implemented a light-weight industry standard protocol ATA over Ethernet (AoE) and we present an outlook of using a file-system on these network-exported disk-drivers.

  17. LHCb: FPGA based data-flow injection module at 10 Gbit/s reading data from network exported storage and using standard protocols

    CERN Multimedia

    Lemouzy, B; Garnier, J-C

    2010-01-01

    The goal of the LHCb readout upgrade is to speed up the DAQ to 40 MHz. Such a DAQ system will certainly employ 10 Gigabit or similar technologies and might also need new networking protocols such as a customized, light-weight TCP or more specialised protocols. A test module is being implemented, which integrates in the existing LHCb infrastructure. It is a multiple 10-Gigabit traffic generator, driven by a Stratix IV FPGA, which is flexibile enough to either generate LHCb's raw data packets internally or read them from external storage via the network. For reading the data we have implemented a light-weight industry standard protocol ATA over Ethernet (AoE) and we present an outlook of using a filesystem on these network-exported disk-drivers.

  18. Performance Comparison of Wireless Sensor Network Standard Protocols in an Aerospace Environment: ISA100.11a and ZigBee Pro

    Science.gov (United States)

    Wagner, Raymond S.; Barton, Richard J.

    2011-01-01

    Standards-based wireless sensor network (WSN) protocols are promising candidates for spacecraft avionics systems, offering unprecedented instrumentation flexibility and expandability. Ensuring reliable data transport is key, however, when migrating from wired to wireless data gathering systems. In this paper, we conduct a rigorous laboratory analysis of the relative performances of the ZigBee Pro and ISA100.11a protocols in a representative crewed aerospace environment. Since both operate in the 2.4 GHz radio frequency (RF) band shared by systems such as Wi-Fi, they are subject at times to potentially debilitating RF interference. We compare goodput (application-level throughput) achievable by both under varying levels of 802.11g Wi-Fi traffic. We conclude that while the simpler, more inexpensive ZigBee Pro protocol performs well under moderate levels of interference, the more complex and costly ISA100.11a protocol is needed to ensure reliable data delivery under heavier interference. This paper represents the first published, rigorous analysis of WSN protocols in an aerospace environment that we are aware of and the first published head-to-head comparison of ZigBee Pro and ISA100.11a.

  19. Development of standardized bioassay protocols for the toxicity assessment of waste, manufactured products, and effluents in Latin America: Venezuela, a Case Study

    International Nuclear Information System (INIS)

    Rodriquez-Grau, J.

    1993-01-01

    The present status of the toxicity assessment of industrial products in Latin America is well below North America/EC standards. As an example, most of Latin America regulatory laws regarding effluent discharge are still based upon concentration limits of certain major pollutants, and BOD/COD measurements; no reference is made to the necessity of aquatic bioassay toxicity data. Aware of this imperative need, the Venezuelan Petroleum Industry (PDVSA), through its R ampersand D Corporative branch (INTEVEP) gave priority to the development of standardized acute/sublethal toxicity test protocols as sound means of evaluating their products and wastes. Throughout this presentation, the Venezuelan case will be studied, showing strategies undertaken to accelerate protocol development. Results will show the assessment of 14 different protocols encompassing a variety of species of aquatic/terrestrial organisms, and a series of toxicity test endpoints including mortality, reproductive, biological and immunological measurements, most of which are currently in use or being developed. These protocols have already yielded useful results in numerous cases where toxicity assessment was required, including evaluations of effluent, oil dispersants, drilling fluids, toxic wastes, fossil fuels and newly developed products. The Venezuelan case demonstrates that the integration of Industry, Academia and Government, which is an essential part of SETAC's philosophy, is absolutely necessary for the successful advancement of environmental scientific/regulatory issues

  20. Standardized Duplex Ultrasound-Based Protocol for Early Diagnosis of Transplant Renal Artery Stenosis: Results of a Single-Institution Retrospective Cohort Study

    Directory of Open Access Journals (Sweden)

    Vincenzo Li Marzi

    2018-01-01

    Full Text Available Transplant renal artery stenosis (TRAS is the most frequent vascular complication after kidney transplantation (KT and has been associated with potentially reversible refractory hypertension, graft dysfunction, and reduced patient survival. The aim of the study is to describe the outcomes of a standardized Duplex Ultrasound- (DU- based screening protocol for early diagnosis of TRAS and for selection of patients potentially requiring endovascular intervention. We retrospectively reviewed our prospectively collected database of KT from January 1998 to select patients diagnosed with TRAS. The follow-up protocol was based on a risk-adapted, dynamic subdivision of eligible KT patients in different risk categories (RC with different protocol strategies (PS. Of 598 patients included in the study, 52 (9% patients had hemodynamically significant TRAS and underwent percutaneous angioplasty (PTA and stent placement. Technical and clinical success rates were 97% and 90%, respectively. 7 cases of restenosis were recorded at follow-up and treated with re-PTA plus stenting. Both DU imaging and clinical parameters improved after stent placement. Prospective high-quality studies are needed to test the efficacy and safety of our protocol in larger series. Accurate trial design and standardized reporting of patient outcomes will be key to address the current clinical needs.

  1. Standard deviation of vertical two-point longitudinal velocity differences in the atmospheric boundary layer.

    Science.gov (United States)

    Fichtl, G. H.

    1971-01-01

    Statistical estimates of wind shear in the planetary boundary layer are important in the design of V/STOL aircraft, and for the design of the Space Shuttle. The data analyzed in this study consist of eleven sets of longitudinal turbulent velocity fluctuation time histories digitized at 0.2 sec intervals with approximately 18,000 data points per time history. The longitudinal velocity fluctuations were calculated with horizontal wind and direction data collected at the 18-, 30-, 60-, 90-, 120-, and 150-m levels. The data obtained confirm the result that Eulerian time spectra transformed to wave-number spectra with Taylor's frozen eddy hypothesis possess inertial-like behavior at wave-numbers well out of the inertial subrange.

  2. Standard echocardiography versus handheld echocardiography for the detection of subclinical rheumatic heart disease: protocol for a systematic review.

    Science.gov (United States)

    Telford, Lisa H; Abdullahi, Leila H; Ochodo, Eleanor A; Zühlke, Liesl J; Engel, Mark E

    2018-02-10

    Rheumatic heart disease (RHD) is a preventable and treatable chronic condition which persists in many developing countries largely affecting impoverished populations. Handheld echocardiography presents an opportunity to address the need for more cost-effective methods of diagnosing RHD in developing countries, where the disease continues to carry high rates of morbidity and mortality. Preliminary studies have demonstrated moderate sensitivity as well as high specificity and diagnostic odds for detecting RHD in asymptomatic patients. We describe a protocol for a systematic review on the diagnostic performance of handheld echocardiography compared to standard echocardiography using the 2012 World Heart Federation criteria for diagnosing subclinical RHD. Electronic databases including PubMed, Scopus, Web of Science and EBSCOhost as well as reference lists and citations of relevant articles will be searched from 2012 to date using a predefined strategy incorporating a combination of Medical Subject Heading terms and keywords. The methodological validity and quality of studies deemed eligible for inclusion will be assessed against review specific Quality Assessment of Diagnostic Accuracy Studies 2 criteria and information on metrics of diagnostic accuracy and demographics extracted. Forest plots of sensitivity and specificity as well as scatter plots in receiver operating characteristic (ROC) space will be used to investigate heterogeneity. If possible, a meta-analysis will be conducted to produce summary results of sensitivity and specificity using the Hierarchical Summary ROC method. In addition, a sensitivity analysis will be conducted to investigate the effect of studies with a high risk of bias. Ethics approval is not required for this systematic review of previously published literature. The planned review will provide a summary of the diagnostic accuracy of handheld echocardiography. Results may feed into evidence-based guidelines and should the findings of this

  3. Standardization of a protocol to obtain genomic DNA for the quantification of 5mC in epicormics buds of Tectona grandis L.

    OpenAIRE

    Elisa Quiala; Luis Valledor; Rodrigo Hazbun; Raúl Barbón; Manuel de Feria; Maité Chávez

    2008-01-01

    The present investigation was carried out with the objective of defining an extraction and purification method that it provided deoxyribonucleic acid (DNA) appropriate to determine the percentage of 5mC in the genomic DNA of epicormics buds of Tectona grandis L. During the standardization of the protocol four methods were compared: 1 -classic based on saline shock solution with CTAB (hexadecil trimetil ammonium bromide), 2 - Kit of extraction of DNA plants DNeasy Plant Mini Kit (QIAGEN) accor...

  4. Effects of Adding an Internet-Based Pain Coping Skills Training Protocol to a Standardized Education and Exercise Program for People With Persistent Hip Pain (HOPE Trial): Randomized Controlled Trial Protocol.

    Science.gov (United States)

    Bennell, Kim L; Rini, Christine; Keefe, Francis; French, Simon; Nelligan, Rachel; Kasza, Jessica; Forbes, Andrew; Dobson, Fiona; Abbott, J Haxby; Dalwood, Andrew; Vicenzino, Bill; Harris, Anthony; Hinman, Rana S

    2015-10-01

    Persistent hip pain in older people is usually due to hip osteoarthritis (OA), a major cause of pain, disability, and psychological dysfunction. The purpose of this study is to evaluate whether adding an Internet-based pain coping skills training (PCST) protocol to a standardized intervention of education followed by physical therapist-instructed home exercise leads to greater reductions in pain and improvements in function. An assessor-, therapist-, and participant-blinded randomized controlled trial will be conducted. The study will be conducted in a community setting. The participants will be 142 people over 50 years of age with self-reported hip pain consistent with hip OA. Participants will be randomly allocated to: (1) a control group receiving a 24-week standardized intervention comprising an 8-week Internet-based education package followed by 5 individual physical therapy exercise sessions plus home exercises (3 times weekly) or (2) a PCST group receiving an 8-week Internet-based PCST protocol in addition to the control intervention. Outcomes will be measured at baseline and 8, 24, and 52 weeks, with the primary time point at 24 weeks. Primary outcomes are hip pain on walking and self-reported physical function. Secondary outcomes include health-related quality-of-life, participant-perceived treatment response, self-efficacy for pain management and function, pain coping attempts, pain catastrophizing, and physical activity. Measurements of adherence, adverse events, use of health services, and process measures will be collected at 24 and 52 weeks. Cost-effectiveness will be assessed at 52 weeks. A self-reported diagnosis of persistent hip pain will be used. The findings will help determine whether adding an Internet-based PCST protocol to standardized education and physical therapist-instructed home exercise is more effective than education and exercise alone for persistent hip pain. This study has the potential to guide clinical practice toward innovative

  5. Effect of Duration of Irrigation with Sodium Hypochlorite in Clinical Protocol of MTAD on Removal of Smear Layer and Creating Dentinal Erosion

    Science.gov (United States)

    Lotfi, Mehrdad; Moghaddam, Negar; Vosoughhosseini, Sepideh; Zand, Vahid; Saghiri, Mohammad Ali

    2012-01-01

    Background and aims The aim of the present study was to compare 1.3% sodium hypochlorite (NaOCl) in MTAD (mixture of tetracycline isomer, acid, and detergent) for the removal of the smear layer and induction of canal erosion. Materials and methods 38 maxillary incisors were divided in three experimental groups of 10 and two positive and negative control groups of each 4 teeth, and prepared using rotary files. In test groups, 1.3% NaOCl was used for 5, 10 and 20 minutes during preparation followed by MTAD as the final rinse. In negative control group, 5.25% NaOCl was used for 10 minutes followed by 17% Ethylenediamine Tetra-Acetic Acid (EDTA) as the final rinse. In positive control group, dis-tilled water was used for 10 minutes during preparation and then as the final rinse. The samples were examined under scan-ning electron microscope, and the smear layer and dentinal erosion scores were recorded. Results Five and 10 min groups had significant differences with 20 min group (p < 0.05). In apical third, 5 and 10 min groups had also significant differences with 20 min (p < 0.05). In the coronal thirds, when the time of irrigation with 1.3% NaOCl increased from 5 min to 20 min, erosion also increased significantly. However, 5 and 10 min groups had no signifi-cant differences with negative control group. Conclusion The use of 1.3% sodium hypochlorite for 5 and 10 minutes in the MTAD protocol removes the smear layer in the coronal and middle thirds but does not induce erosion. PMID:22991642

  6. Effectiveness of individualized physiotherapy on pain and functioning compared to a standard exercise protocol in patients presenting with clinical signs of subacromial impingement syndrome. A randomized controlled trial

    Directory of Open Access Journals (Sweden)

    de Bie Rob A

    2010-06-01

    Full Text Available Abstract Background Shoulder impingement syndrome is a common musculoskeletal complaint leading to significant reduction of health and disability. Physiotherapy is often the first choice of treatment although its effectiveness is still under debate. Systematic reviews in this field highlight the need for more high quality trials to investigate the effectiveness of physiotherapy interventions in patients with subacromial impingement syndrome. Methods/Design This randomized controlled trial will investigate the effectiveness of individualized physiotherapy in patients presenting with clinical signs and symptoms of subacromial impingement, involving 90 participants aged 18-75. Participants are recruited from outpatient physiotherapy clinics, general practitioners, and orthopaedic surgeons in Germany. Eligible participants will be randomly allocated to either individualized physiotherapy or to a standard exercise protocol using central randomization. The control group will perform the standard exercise protocol aiming to restore muscular deficits in strength, mobility, and coordination of the rotator cuff and the shoulder girdle muscles to unload the subacromial space during active movements. Participants of the intervention group will perform the standard exercise protocol as a home program, and will additionally be treated with individualized physiotherapy based on clinical examination results, and guided by a decision tree. After the intervention phase both groups will continue their home program for another 7 weeks. Outcome will be measured at 5 weeks and at 3 and 12 months after inclusion using the shoulder pain and disability index and patients' global impression of change, the generic patient-specific scale, the average weekly pain score, and patient satisfaction with treatment. Additionally, the fear avoidance beliefs questionnaire, the pain catastrophizing scale, and patients' expectancies of treatment effect are assessed. Participants

  7. Intra-rater and inter-rater reliability of the standardized ultrasound protocol for assessing subacromial structures

    DEFF Research Database (Denmark)

    Hougs Kjær, Birgitte; Ellegaard, Karen; Wieland, Ina

    2017-01-01

    BACKGROUND: US-examinations related to shoulder impingement (SI) often vary due to methodological differences, examiner positions, transducers, and recording parameters. Reliable US protocols for examination of different structures related to shoulder impingement are therefore needed. OBJECTIVES...... of the supraspinatus tendon (SUPRA) and subacromial subdeltoid (SASD) bursa in two imaging positions, and the acromial humeral distance (AHD) in one position. Additionally, agreement on dynamic impingement (DI) examination was performed. The intra- and inter-rater reliability was carried out on the same day...

  8. Performance evaluation of working standard NE2581 in comparison with reference standard NE2561 in the determination of absorbed dose to water using IAEA, HPA, NACP, AAPM, NCRP and ICRU protocols

    International Nuclear Information System (INIS)

    Dolah, M.T.; Supian Samat; Taiman Kadni

    2001-01-01

    The aim of this study was to evaluate the performance of NE 2581 in comparison with NE 2561 in the determination of the absorbed dose to water in a γ-ray beam using IAEA, HPA, NACP, AAPM, NCRP and ICRU protocols. 13 exposures of the γ-ray beams were used. This number of exposures yielded 26 chamber rate readings for NE 2581 (N=13) and for NE 2561 (N=13). From the 13 NE 2581 readings, 78 absorbed dose to water values were calculated for the IAEA (N=13), HPA (N=13), NACP (N=13), AAPM (N=13), NCRP (N=13) and ICRU (N=13) protocols. Similarly, from the 13 NE 2561 readings, 78 absorbed dose to water values were calculated for IAEA (N=13), HPA (N=13), NACP (N=13), AAPM (N=13), NCRP (N=13) and ICRU (N=13) protocols. From these 156 (=78 x 2) absorbed dose to water values, 78 percentage deviations between the NE 2581 and NE 2561 results were calculated for IAEA (N=13), HPA (N=13), NACP (N=13), AAPM (N=13), NCRP (N=13) and ICRU (N=13) protocols. For a single protocol, the mean μ and standard error σ+s+e of the percentage deviations (N=13) were calculated. results obtained in terms of [protocol, μ ± σ se ] were [IAEA,1.55 ± 0.12], [HPA, 0.98 ± 0.12], [NACP, 1.93 ± 0.12], [AAPM, -0.06 ± 0.12], [NCRP, 0.97 ± 0.12], [ICRU, 0.97 ± 0.12]. It can be seen that the range of percentage deviations is from -0.06 to 1.93. As the quoted IAEA acceptable limit of deviation is ± 3.0%, it was concluded that the working standard NE 2581 chamber has shown acceptable performance. In addition, the use of the AAPM protocol has enable NE 2581 to show a performance that is very similar like NE 2561. (Author)

  9. Smear layer removal evaluation of different protocol of Bio Race file and XP- endo Finisher file in corporation with EDTA 17% and NaOCl.

    Science.gov (United States)

    Zand, Vahid; Mokhtari, Hadi; Reyhani, Mohammad-Frough; Nahavandizadeh, Neda; Azimi, Shahram

    2017-11-01

    The aim of the present study was to compare the amount of the smear layer remaining in prepared root canals with different protocols of Bio RaCe files and XP-endo Finisher file (XPF) in association with 17% EDTA and sodium hypochlorite solution. A total of 68 extracted single-rooted teeth were randomly divided into 4 experimental groups (n=14) and two control groups (n=6). The root canals were prepared with Bio RaCe files (FKG Dentaire, Switzerland) using the crown-down technique based on manufacturer's instructions and irrigated according to the following irrigation techniques: Group 1: XPF with 2 mL of 2.5% NaOCl for 1 minute. Group 2:, XPF with 1 mL of 17% EDTA for one minute. Group 3: XPF was used for 1 minute in association with normal saline solution. Group 4: XP-endo Finisher file for 30 seconds in association with 2.5% NaOCl and 17% EDTA for 30 seconds. The negative control group: NaOCl (2.5%) was used during root canal preparation, followed by irrigation with 17% EDTA at the end of root canal preparation. The positive control group: Normal saline solution was used for irrigation during root canal preparation. In all the groups, during preparation of the root canals with Bio RaCe file, 20 mL of 2.5% NaOCl was used for root canal irrigation and at the end of the procedural steps 20 mL of normal saline solution was used as a final irrigant. The samples were analyzed under SEM at ×1000‒2000 magnification and evaluated using Torabinejad scoring system. Data were analyzed with non-parametric Kruskal-Wallis test and post hoc Mann-Whitney U test, using SPSS. Statistical significant was defined at P <0.05. The results of the study showed the least amount of the smear layer at coronal, middle and apical thirds of the root canals in groups 2, which was not significantly different from the negative control group ( P <0.5). Under the limitations of the present study, use of a combination of NaOCl and EDTA in association with XPF exhibited the best efficacy for the

  10. Anthropometric standardisation and quality control protocols for the construction of new, international, fetal and newborn growth standards: the INTERGROWTH-21st Project.

    Science.gov (United States)

    Cheikh Ismail, L; Knight, H E; Ohuma, E O; Hoch, L; Chumlea, W C

    2013-09-01

    The primary aim of the INTERGROWTH-21(st) Project is to construct new, prescriptive standards describing optimal fetal and preterm postnatal growth. The anthropometric measurements include the head circumference, recumbent length and weight of the infants, and the stature and weight of the parents. In such a large, international, multicentre project, it is critical that all study sites follow standardised protocols to ensure maximal validity of the growth and nutrition indicators used. This paper describes in detail the anthropometric training, standardisation and quality control procedures used to collect data for these new standards. The initial standardisation session was in Nairobi, Kenya, using newborns, which was followed by similar sessions in the eight participating study sites in Brazil, China, India, Italy, Kenya, Oman, UK and USA. The intraobserver and inter-observer technical error of measurement values for head circumference range from 0.3 to 0.4 cm, and for recumbent length from 0.3 to 0.5 cm. These standardisation protocols implemented at each study site worldwide ensure that the anthropometric data collected are of the highest quality to construct international growth standards. © 2013 Royal College of Obstetricians and Gynaecologists.

  11. Effects of standard training in the use of closed-circuit televisions in visually impaired adults: design of a training protocol and a randomized controlled trial

    Directory of Open Access Journals (Sweden)

    van Rens Ger HMB

    2010-03-01

    Full Text Available Abstract Background Reading problems are frequently reported by visually impaired persons. A closed-circuit television (CCTV can be helpful to maintain reading ability, however, it is difficult to learn how to use this device. In the Netherlands, an evidence-based rehabilitation program in the use of CCTVs was lacking. Therefore, a standard training protocol needed to be developed and tested in a randomized controlled trial (RCT to provide an evidence-based training program in the use of this device. Methods/Design To develop a standard training program, information was collected by studying literature, observing training in the use of CCTVs, discussing the content of the training program with professionals and organizing focus and discussion groups. The effectiveness of the program was evaluated in an RCT, to obtain an evidence-based training program. Dutch patients (n = 122 were randomized into a treatment group: normal instructions from the supplier combined with training in the use of CCTVs, or into a control group: instructions from the supplier only. The effect of the training program was evaluated in terms of: change in reading ability (reading speed and reading comprehension, patients' skills to operate the CCTV, perceived (vision-related quality of life and tasks performed in daily living. Discussion The development of the CCTV training protocol and the design of the RCT in the present study may serve as an example to obtain an evidence-based training program. The training program was adjusted to the needs and learning abilities of individual patients, however, for scientific reasons it might have been preferable to standardize the protocol further, in order to gain more comparable results. Trial registration http://www.trialregister.nl, identifier: NTR1031

  12. New Acquisition Protocol of 18F-Choline PET/CT in Prostate Cancer Patients: Review of the Literature about Methodology and Proposal of Standardization

    Directory of Open Access Journals (Sweden)

    Sotirios Chondrogiannis

    2014-01-01

    Full Text Available Purpose. (1 To evaluate a new acquisition protocol of 18F-choline (FCH PET/CT for prostate cancer patients (PC, (2 to review acquisition 18F-choline PET/CT methodology, and (3 to propose a standardized acquisition protocol on FCH PET/CT in PC patients. Materials. 100 consecutive PC patients (mean age 70.5 years, mean PSA 21.35 ng/mL were prospectively evaluated. New protocol consisted of an early scan of the pelvis immediately after the injection of the tracer (1 bed position of 4 min followed by a whole body scan at one 1 hour. Early and 1 hour images were compared for interfering activity and pathologic findings. Results. The overall detection rate of FCH PET/CT was 64%. The early static images of the pelvis showed absence of radioactive urine in ureters, bladder, or urethra which allowed a clean evaluation of the prostatic fossae. Uptake in the prostatic region was better visualized in the early phase in 26% (7/30 of cases. Other pelvic pathologic findings (bone and lymph nodes were visualized in both early and late images. Conclusion. Early 18F-choline images improve visualization of abnormal uptake in prostate fossae. All pathologic pelvic deposits (prostate, lymph nodes, and bone were visualized in both early and late images.

  13. Standardization of a Protocol for Obtaining Platelet Rich Plasma from blood Donors; a Tool for Tissue Regeneration Procedures.

    Science.gov (United States)

    Gómez, Lina Andrea; Escobar, Magally; Peñuela, Oscar

    2015-01-01

    To develop a protocol for obtaining autologous platelet rich plasma in healthy individuals and to determine the concentration of five major growth factors before platelet activation. This protocol could be integrated into the guidelines of good clinical practice and research in regenerative medicine. Platelet rich plasma was isolated by centrifugation from 38 healthy men and 42 women ranging from 18 to 59 years old. The platelet count and quantification of growth factors were analyzed in eighty samples, stratified for age and gender of the donor. Analyses were performed using parametric the t-test or Pearson's analysis for non-parametric distribution. P platelet counts from 1.6 to 4.9 times (mean = 2.8). There was no correlation between platelet concentration and the level of the following growth factors: VEGF-D (r = 0.009, p = 0.4105), VEGF-A (r = 0.0068, p = 0.953), PDGF subunit AA (p = 0.3618; r = 0.1047), PDGF-BB (p = 0.5936; r = 0.6095). In the same way, there was no correlation between donor gender and growth factor concentrations. Only TGF-β concentration was correlated to platelet concentration (r = 0.3163, p = 0.0175). The procedure used allowed us to make preparations rich in platelets, low in leukocytes and red blood cells, and sterile. Our results showed biological variations in content of growth factors in PRP. The factors influencing these results should be further studied.

  14. A Simple XML Producer-Consumer Protocol

    Science.gov (United States)

    Smith, Warren; Gunter, Dan; Quesnel, Darcy; Biegel, Bryan (Technical Monitor)

    2001-01-01

    performance data. These standard protocols and representations must support tasks such as profiling parallel applications, monitoring the status of computers and networks, and monitoring the performance of services provided by a computational grid. This paper describes a proposed protocol and data representation for the exchange of events in a distributed system. The protocol exchanges messages formatted in XML and it can be layered atop any low-level communication protocol such as TCP or UDP Further, we describe Java and C++ implementations of this protocol and discuss their performance. The next section will provide some further background information. Section 3 describes the main communication patterns of our protocol. Section 4 describes how we represent events and related information using XML. Section 5 describes our protocol and Section 6 discusses the performance of two implementations of the protocol. Finally, an appendix provides the XML Schema definition of our protocol and event information.

  15. Patient controlled sedation using a standard protocol for dressing changes in burns: patients' preference, procedural details and a preliminary safety evaluation.

    Science.gov (United States)

    Nilsson, Andreas; Steinvall, Ingrid; Bak, Zoltan; Sjöberg, Folke

    2008-11-01

    Patient controlled sedation (PCS) enables patients to titrate doses of drugs by themselves during different procedures involving pain or discomfort. We studied it in a prospective crossover design using a fixed protocol without lockout time to examine it as an alternative method of sedation for changing dressings in burned patients. Eleven patients with >10% total burn surface area (TBSA) had their dressings changed, starting with sedation by an anaesthetist (ACS). The second dressing change was done with PCS (propofol/alfentanil) and the third time the patients had to choose ACS or PCS. During the procedures, data on cardiopulmonary variables, sedation (bispectral index), pain intensity (VAS), procedural details, doses of drugs, and patients' preferences were collected to compare the two sedation techniques. The study data indicated that wound care in burned patients is feasible with a standardized PCS protocol. The patients preferred PCS to ACS on the basis of self-control, and because they had less discomfort during the recovery period. Wound care was also considered adequate by the staff during PCS. No respiratory (respiratory rate/transcutaneous PCO(2)) or cardiovascular (heart rate/blood pressure) adverse events were recorded at any time during any of the PCS procedures. The doses of propofol and alfentanil and BIS index decrease were less during PCS than ACS. Procedural pain was higher during PCS but lower after the procedure. We suggest that PCS using a standard protocol is an interesting alternative to anaesthetist-provided sedation during dressing changes. It seems effective, saves resources, is safe, and at same time is preferred by the patients. The strength of these conclusions is, however, hampered by the small size of this investigation and therefore further studies are warranted.

  16. Visualization of the internal globus pallidus: sequence and orientation for deep brain stimulation using a standard installation protocol at 3.0 Tesla.

    Science.gov (United States)

    Nölte, Ingo S; Gerigk, Lars; Al-Zghloul, Mansour; Groden, Christoph; Kerl, Hans U

    2012-03-01

    Deep-brain stimulation (DBS) of the internal globus pallidus (GPi) has shown remarkable therapeutic benefits for treatment-resistant neurological disorders including dystonia and Parkinson's disease (PD). The success of the DBS is critically dependent on the reliable visualization of the GPi. The aim of the study was to evaluate promising 3.0 Tesla magnetic resonance imaging (MRI) methods for pre-stereotactic visualization of the GPi using a standard installation protocol. MRI at 3.0 T of nine healthy individuals and of one patient with PD was acquired (FLAIR, T1-MPRAGE, T2-SPACE, T2*-FLASH2D, susceptibility-weighted imaging mapping (SWI)). Image quality and visualization of the GPi for each sequence were assessed by two neuroradiologists independently using a 6-point scale. Axial, coronal, and sagittal planes of the T2*-FLASH2D images were compared. Inter-rater reliability, contrast-to-noise ratios (CNR) and signal-to-noise ratios (SNR) for the GPi were determined. For illustration, axial T2*-FLASH2D images were fused with a section schema of the Schaltenbrand-Wahren stereotactic atlas. The GPi was best and reliably visualized in axial and to a lesser degree on coronal T2*-FLASH2D images. No major artifacts in the GPi were observed in any of the sequences. SWI offered a significantly higher CNR for the GPi compared to standard T2-weighted imaging using the standard parameters. The fusion of the axial T2*-FLASH2D images and the atlas projected the GPi clearly in the boundaries of the section schema. Using a standard installation protocol at 3.0 T T2*-FLASH2D imaging (particularly axial view) provides optimal and reliable delineation of the GPi.

  17. Marker based standardization of polyherbal formulation (SJT-DI-02 by high performance thin layer chromatography method

    Directory of Open Access Journals (Sweden)

    Bhakti J Ladva

    2014-01-01

    purity of the bands due to marker compounds in the sample extracts were confirmed by overlaying the absorption spectra recorded at start, middle and end position of the band in the sample tracks. After conforming all these things fingerprints were developed for all three formulations which will be act as authentification and quality control tool. Results: % w/w of asarones is 3.61, % w/w of marmelosin is 4.60, % w/w of gallic acid is 10.80 and % w/w of lupeol is 4.13.The method was validated in terms of linearity, precision, repeatability, limit of detection, limit of quantification and accuracy. In well-developed mobile phase system linearity was found to be in the range of 0.983-0.995, % recovery was found to be in the range of 97.48-99.63, % RSD for intraday and interday was found to be 0.13- 0.70 and 0.32 -1.41 and LOD and LOQ was found to be in the range of 0.15- 0.61 and 0.45 -1.83 microgram per ml. Conclusion: Thus High performance thin layer chromatography (HPTLC methods were developed and validated in terms of linearity, precision, repeatability, limit of detection, limit of quantification and accuracy. The methods were rapid, sensitive, reproducible and economical. It does not suffer any positive or negative interference due to common other component present in the formulation and would also serve as a tool for authentication of herbal products containing marmelosin, gallic acid, lupeol and asarones. Thus this work provides standardized and therapeutically active polyherbal formulations for the different ailments.

  18. Clinical trials of CCLSG L874 and I874 protocols without cranial irradiation for standard-risk acute lymphoblastic leukemia in childhood

    International Nuclear Information System (INIS)

    Koizumi, Shoichi; Fujimoto, Takeo; Tsurusawa, Masahito

    1992-01-01

    In the CCLSG-874 protocol for children with low-risk (LR) and intermediate-risk (IR) acute lymphoblastic leukemia (ALL), two regimens with or without cranial irradiation (CI) were compared with respect to their ability to prevent central nervous system (CNS) leukemia and to improve overall outcome of ALL. From 1987 to 1990, 82 and 109 evaluable patients were registered into L874 and I874 protocols for LR and IR patients, respectively. All responders to induction therapy were randomized to treatment with 18 Gy of CI plus intrathecal methotrexate (MTX it) or to treatment with high-dose MTX plus MTX it. Patients were then treated with standard maintenance regimens of L874 and I874. At a median follow-up of 39 months (range 14-58 months) there was no difference in the rate of hematologic relapse between the CI group and MTX group. The rate of CNS relapse in the MTX group seemed to be higher (3 of 39 in L874 and 2 of 54 in I874) than that in the CI group (1 of 43 in L874 and 0 of 55 in I874), but these data were not statistically significant. The rates of 4-year event-free survival (EFS) in L874 were 81.1±7.6% (mean±SE) and 75.2±7.9% (ns) for the CI and MTX group, respectively, and the rates of EFS in I874 were 70.0±13.6% and 70.0±9.0% (ns) for the CI and MTX group, respectively. These data suggest that MTX alone may be as effective as CI to prolong disease-free survival in LR and IR ALL although further continuous studies are needed. Analysis of serial CCLSG protocols for ALL from 1981 revealed that the rate of EFS of ALL allover including all risk groups has gradually been increasing from 44.2±3.6% for 811 protocol and 53.1±3.5% for 841 to 65.5±3.6% for the present 874 protocol. (author)

  19. Analysis of the Implementation of Standardized Clinical Protocol «Diabetes Mellitus Type 2» by Quality Indicators in Institutions of Kyiv Region

    Directory of Open Access Journals (Sweden)

    V.I. Tkachenko

    2014-10-01

    Full Text Available In Ukraine, a standardized clinical protocol (SCP to provide medical care in diabetes mellitus type 2 (order of the Ministry of Healthcare of Ukraine dated 21.12.2012 № 1118, which identifies 4 quality indicators, is being implemented. The objective of research — to analyze the implementation of SCP based on monitoring of quality indicators in the institutions of the Kyiv region. Materials and Methods. Technique for assessing the quality of diabetes care, one element of which is the monitoring of quality indicators specified in SCP, has been developed and applied. Collection and analysis of information was carried out by forms of primary records № 025/030 and 030/o, forms of statistical reporting № 12 and 20. Statistical analysis was performed using Excel 2007, SPSS. Results. Today, primary health care institutions in Kyiv region developed local protocols that confirms the implementation of the first quality indicator, in accordance with the desired level of the indicator value by SCP. The second indicator — the percentage of patients who were defined the level of glycated hemoglobin in the reporting period amounted to 12.2 %, which is higher than in 2012 (8.84 %, but remains low. The third quality indicator — the percentage of patients who were admitted to hospital for diabetes mellitus and its complications during the reporting period amounted to 15.01 %, while in 2012 it stood at 8.66 %. For comparison, this figure in 2007 was 9.37 %. Conclusions. The quality of care at an early stage of implementation is not enough, partly due to the lack of awareness by physicians of major provisions of the protocol, lack of equipment, the need of payment by a patient for medical services specified in the protocol, lack of doctors’ understanding of the characteristics of different types of medical and technological documents and difficulties in the development and implementation of local protocols, particularly. The obtained results are

  20. Laparoscopic colorectal surgery in learning curve: Role of implementation of a standardized technique and recovery protocol. A cohort study

    Directory of Open Access Journals (Sweden)

    Gaetano Luglio

    2015-06-01

    Conclusion: Proper laparoscopic colorectal surgery is safe and leads to excellent results in terms of recovery and short term outcomes, even in a learning curve setting. Key factors for better outcomes and shortening the learning curve seem to be the adoption of a standardized technique and training model along with the strict supervision of an expert colorectal surgeon.

  1. Comparison of mRNA splicing assay protocols across multiple laboratories: recommendations for best practice in standardized clinical testing.

    Science.gov (United States)

    Whiley, Phillip J; de la Hoya, Miguel; Thomassen, Mads; Becker, Alexandra; Brandão, Rita; Pedersen, Inge Sokilde; Montagna, Marco; Menéndez, Mireia; Quiles, Francisco; Gutiérrez-Enríquez, Sara; De Leeneer, Kim; Tenés, Anna; Montalban, Gemma; Tserpelis, Demis; Yoshimatsu, Toshio; Tirapo, Carole; Raponi, Michela; Caldes, Trinidad; Blanco, Ana; Santamariña, Marta; Guidugli, Lucia; de Garibay, Gorka Ruiz; Wong, Ming; Tancredi, Mariella; Fachal, Laura; Ding, Yuan Chun; Kruse, Torben; Lattimore, Vanessa; Kwong, Ava; Chan, Tsun Leung; Colombo, Mara; De Vecchi, Giovanni; Caligo, Maria; Baralle, Diana; Lázaro, Conxi; Couch, Fergus; Radice, Paolo; Southey, Melissa C; Neuhausen, Susan; Houdayer, Claude; Fackenthal, Jim; Hansen, Thomas Van Overeem; Vega, Ana; Diez, Orland; Blok, Rien; Claes, Kathleen; Wappenschmidt, Barbara; Walker, Logan; Spurdle, Amanda B; Brown, Melissa A

    2014-02-01

    Accurate evaluation of unclassified sequence variants in cancer predisposition genes is essential for clinical management and depends on a multifactorial analysis of clinical, genetic, pathologic, and bioinformatic variables and assays of transcript length and abundance. The integrity of assay data in turn relies on appropriate assay design, interpretation, and reporting. We conducted a multicenter investigation to compare mRNA splicing assay protocols used by members of the ENIGMA (Evidence-Based Network for the Interpretation of Germline Mutant Alleles) consortium. We compared similarities and differences in results derived from analysis of a panel of breast cancer 1, early onset (BRCA1) and breast cancer 2, early onset (BRCA2) gene variants known to alter splicing (BRCA1: c.135-1G>T, c.591C>T, c.594-2A>C, c.671-2A>G, and c.5467+5G>C and BRCA2: c.426-12_8delGTTTT, c.7988A>T, c.8632+1G>A, and c.9501+3A>T). Differences in protocols were then assessed to determine which elements were critical in reliable assay design. PCR primer design strategies, PCR conditions, and product detection methods, combined with a prior knowledge of expected alternative transcripts, were the key factors for accurate splicing assay results. For example, because of the position of primers and PCR extension times, several isoforms associated with BRCA1, c.594-2A>C and c.671-2A>G, were not detected by many sites. Variation was most evident for the detection of low-abundance transcripts (e.g., BRCA2 c.8632+1G>A Δ19,20 and BRCA1 c.135-1G>T Δ5q and Δ3). Detection of low-abundance transcripts was sometimes addressed by using more analytically sensitive detection methods (e.g., BRCA2 c.426-12_8delGTTTT ins18bp). We provide recommendations for best practice and raise key issues to consider when designing mRNA assays for evaluation of unclassified sequence variants.

  2. Randomised social-skills training and parental training plus standard treatment versus standard treatment of children with attention deficit hyperactivity disorder - The SOSTRA trial protocol

    Directory of Open Access Journals (Sweden)

    Thomsen Per

    2011-01-01

    Full Text Available Abstract Background Children with attention deficit hyperactivity disorder (ADHD are hyperactive and impulsive, cannot maintain attention, and have difficulties with social interactions. Medical treatment may alleviate symptoms of ADHD, but seldom solves difficulties with social interactions. Social-skills training may benefit ADHD children in their social interactions. We want to examine the effects of social-skills training on difficulties related to the children's ADHD symptoms and social interactions. Methods/Design The design is randomised two-armed, parallel group, assessor-blinded trial. Children aged 8-12 years with a diagnosis of ADHD are randomised to social-skills training and parental training plus standard treatment versus standard treatment alone. A sample size calculation estimated that at least 52 children must be included to show a 4-point difference in the primary outcome on the Conners 3rd Edition subscale for 'hyperactivity-impulsivity' between the intervention group and the control group. The outcomes will be assessed 3 and 6 months after randomisation. The primary outcome measure is ADHD symptoms. The secondary outcome is social skills. Tertiary outcomes include the relationship between social skills and symptoms of ADHD, the ability to form attachment, and parents' ADHD symptoms. Discussion We hope that the results from this trial will show that the social-skills training together with medication may have a greater general effect on ADHD symptoms and social and emotional competencies than medication alone. Trial registration ClinicalTrials (NCT: NCT00937469

  3. Performance Comparison of Wireless Sensor Network Standard Protocols in an Aerospace Environment: ISA100.11a and ZigBee

    Science.gov (United States)

    Wagner, Raymond S.; Barton, Richard J.

    2011-01-01

    Wireless Sensor Networks (WSNs) can provide a substantial benefit in spacecraft systems, reducing launch weight and providing unprecedented flexibility by allowing instrumentation capabilities to grow and change over time. Achieving data transport reliability on par with that of wired systems, however, can prove extremely challenging in practice. Fortunately, much progress has been made in developing standard WSN radio protocols for applications from non-critical home automation to mission-critical industrial process control. The relative performances of candidate protocols must be compared in representative aerospace environments, however, to determine their suitability for spaceflight applications. In this paper, we will present the results of a rigorous laboratory analysis of the performance of two standards-based, low power, low data rate WSN protocols: ZigBee Pro and ISA100.11a. Both are based on IEEE 802.15.4 and augment that standard's specifications to build complete, multi-hop networking stacks. ZigBee Pro targets primarily the home and office automation markets, providing an ad-hoc protocol that is computationally lightweight and easy to implement in inexpensive system-on-a-chip components. As a result of this simplicity, however, ZigBee Pro can be susceptible to radio frequency (RF) interference. ISA100.11a, on the other hand, targets the industrial process control market, providing a robust, centrally-managed protocol capable of tolerating a significant amount of RF interference. To achieve these gains, a coordinated channel hopping mechanism is employed, which entails a greater computational complexity than ZigBee and requires more sophisticated and costly hardware. To guide future aerospace deployments, we must understand how well these standards relatively perform in analog environments under expected operating conditions. Specifically, we are interested in evaluating goodput -- application level throughput -- in a representative crewed environment

  4. Personalized versus standardized dosing strategies for the treatment of childhood amblyopia: study protocol for a randomized controlled trial.

    Science.gov (United States)

    Moseley, Merrick J; Wallace, Michael P; Stephens, David A; Fielder, Alistair R; Smith, Laura C; Stewart, Catherine E

    2015-04-25

    Amblyopia is the commonest visual disorder of childhood in Western societies, affecting, predominantly, spatial visual function. Treatment typically requires a period of refractive correction ('optical treatment') followed by occlusion: covering the nonamblyopic eye with a fabric patch for varying daily durations. Recent studies have provided insight into the optimal amount of patching ('dose'), leading to the adoption of standardized dosing strategies, which, though an advance on previous ad-hoc regimens, take little account of individual patient characteristics. This trial compares the effectiveness of a standardized dosing strategy (that is, a fixed daily occlusion dose based on disease severity) with a personalized dosing strategy (derived from known treatment dose-response functions), in which an initially prescribed occlusion dose is modulated, in a systematic manner, dependent on treatment compliance. A total of 120 children aged between 3 and 8 years of age diagnosed with amblyopia in association with either anisometropia or strabismus, or both, will be randomized to receive either a standardized or a personalized occlusion dose regimen. To avoid confounding by the known benefits of refractive correction, participants will not be randomized until they have completed an optical treatment phase. The primary study objective is to determine whether, at trial endpoint, participants receiving a personalized dosing strategy require fewer hours of occlusion than those in receipt of a standardized dosing strategy. Secondary objectives are to quantify the relationship between observed changes in visual acuity (logMAR, logarithm of the Minimum Angle of Resolution) with age, amblyopia type, and severity of amblyopic visual acuity deficit. This is the first randomized controlled trial of occlusion therapy for amblyopia to compare a treatment arm representative of current best practice with an arm representative of an entirely novel treatment regimen based on statistical

  5. Simultaneous validation of the SunTech CT40 automated blood pressure measurement device by the 1993 British Hypertension Society protocol and the Association for the Advancement of Medical Instrumentation/International Organization for Standardization 81060-2: 2013 standard.

    Science.gov (United States)

    Polo Friz, Hernan; Punzi, Veronica; Petri, Francesco; Orlandi, Riccardo; Maggiolini, Daniele; Polo Friz, Melisa; Primitz, Laura; Vighi, Giuseppe

    2017-10-01

    This study aimed to perform a simultaneous, third-party, independent validation of the oscillometric SunTech CT40 device for blood pressure (BP) measurement, according to the 1993 protocol of the British Hypertension Society and the standard of the Association for the Advancement of Medical Instrumentation (AAMI)/the International Organization for Standardization (ISO) 81060-2:2013. Patient recruitment, study procedures, and data analysis followed the recommendations stated by the protocols. The study was approved by the institutional review board. A total of 94 participants were included, 52 (55.3%) women, mean±SD age: 63.1±18.0 years, mean±SD arm circumference: 35.0±9.0 cm. The average of observers' entry BPs was 146.9±37.2 mmHg for systolic blood pressure (SBP) and 82.2±22.1 mmHg for diastolic blood pressure (DBP). Differences between the standard measurement and the test device within 5, 10, and 15 mmHg, for the better observer, were 79.4, 96.5, and 100.0% for SBP and 82.6, 97.5, and 100.0% for DBP, respectively. The mean±SD differences between the readings obtained using the test device and those obtained by the observers (AAMI/ISO 81060-2:2013 standard criterion 1) were 0.3±5.0 mmHg (SBP) and -0.8±4.3 mmHg (DBP), and the mean±SD differences between average of reference readings and average of test device readings in each patient (criterion 2) were 0.3±3.9 and -0.8±3.5 mmHg for SBP and DBP, respectively. The CT40 BP device achieved A/A grade of the British Hypertension Society protocol and fulfilled the requirements (criteria 1 and 2) of the AAMI/ISO standard. CT40 can be recommended for BP measurement in adults.

  6. A cross-platform survey of CT image quality and dose from routine abdomen protocols and a method to systematically standardize image quality.

    Science.gov (United States)

    Favazza, Christopher P; Duan, Xinhui; Zhang, Yi; Yu, Lifeng; Leng, Shuai; Kofler, James M; Bruesewitz, Michael R; McCollough, Cynthia H

    2015-11-07

    Through this investigation we developed a methodology to evaluate and standardize CT image quality from routine abdomen protocols across different manufacturers and models. The influence of manufacturer-specific automated exposure control systems on image quality was directly assessed to standardize performance across a range of patient sizes. We evaluated 16 CT scanners across our health system, including Siemens, GE, and Toshiba models. Using each practice's routine abdomen protocol, we measured spatial resolution, image noise, and scanner radiation output (CTDIvol). Axial and in-plane spatial resolutions were assessed through slice sensitivity profile (SSP) and modulation transfer function (MTF) measurements, respectively. Image noise and CTDIvol values were obtained for three different phantom sizes. SSP measurements demonstrated a bimodal distribution in slice widths: an average of 6.2  ±  0.2 mm using GE's 'Plus' mode reconstruction setting and 5.0  ±  0.1 mm for all other scanners. MTF curves were similar for all scanners. Average spatial frequencies at 50%, 10%, and 2% MTF values were 3.24  ±  0.37, 6.20  ±  0.34, and 7.84  ±  0.70 lp cm(-1), respectively. For all phantom sizes, image noise and CTDIvol varied considerably: 6.5-13.3 HU (noise) and 4.8-13.3 mGy (CTDIvol) for the smallest phantom; 9.1-18.4 HU and 9.3-28.8 mGy for the medium phantom; and 7.8-23.4 HU and 16.0-48.1 mGy for the largest phantom. Using these measurements and benchmark SSP, MTF, and image noise targets, CT image quality can be standardized across a range of patient sizes.

  7. Effect of standardized training on the reliability of the Cochrane risk of bias assessment tool: a study protocol.

    Science.gov (United States)

    da Costa, Bruno R; Resta, Nina M; Beckett, Brooke; Israel-Stahre, Nicholas; Diaz, Alison; Johnston, Bradley C; Egger, Matthias; Jüni, Peter; Armijo-Olivo, Susan

    2014-12-13

    The Cochrane risk of bias (RoB) tool has been widely embraced by the systematic review community, but several studies have reported that its reliability is low. We aim to investigate whether training of raters, including objective and standardized instructions on how to assess risk of bias, can improve the reliability of this tool. We describe the methods that will be used in this investigation and present an intensive standardized training package for risk of bias assessment that could be used by contributors to the Cochrane Collaboration and other reviewers. This is a pilot study. We will first perform a systematic literature review to identify randomized clinical trials (RCTs) that will be used for risk of bias assessment. Using the identified RCTs, we will then do a randomized experiment, where raters will be allocated to two different training schemes: minimal training and intensive standardized training. We will calculate the chance-corrected weighted Kappa with 95% confidence intervals to quantify within- and between-group Kappa agreement for each of the domains of the risk of bias tool. To calculate between-group Kappa agreement, we will use risk of bias assessments from pairs of raters after resolution of disagreements. Between-group Kappa agreement will quantify the agreement between the risk of bias assessment of raters in the training groups and the risk of bias assessment of experienced raters. To compare agreement of raters under different training conditions, we will calculate differences between Kappa values with 95% confidence intervals. This study will investigate whether the reliability of the risk of bias tool can be improved by training raters using standardized instructions for risk of bias assessment. One group of inexperienced raters will receive intensive training on risk of bias assessment and the other will receive minimal training. By including a control group with minimal training, we will attempt to mimic what many review authors

  8. Revised Recommendations of the Consortium of MS Centers Task Force for a Standardized MRI Protocol and Clinical Guidelines for the Diagnosis and Follow-Up of Multiple Sclerosis

    Science.gov (United States)

    Traboulsee, A.; Simon, J.H.; Stone, L.; Fisher, E.; Jones, D.E.; Malhotra, A.; Newsome, S.D.; Oh, J.; Reich, D.S.; Richert, N.; Rammohan, K.; Khan, O.; Radue, E.-W.; Ford, C.; Halper, J.; Li, D.

    2016-01-01

    SUMMARY An international group of neurologists and radiologists developed revised guidelines for standardized brain and spinal cord MR imaging for the diagnosis and follow-up of MS. A brain MR imaging with gadolinium is recommended for the diagnosis of MS. A spinal cord MR imaging is recommended if the brain MR imaging is nondiagnostic or if the presenting symptoms are at the level of the spinal cord. A follow-up brain MR imaging with gadolinium is recommended to demonstrate dissemination in time and ongoing clinically silent disease activity while on treatment, to evaluate unexpected clinical worsening, to re-assess the original diagnosis, and as a new baseline before starting or modifying therapy. A routine brain MR imaging should be considered every 6 months to 2 years for all patients with relapsing MS. The brain MR imaging protocol includes 3D T1-weighted, 3D T2-FLAIR, 3D T2-weighted, post-single-dose gadolinium-enhanced T1-weighted sequences, and a DWI sequence. The progressive multifocal leukoencephalopathy surveillance protocol includes FLAIR and DWI sequences only. The spinal cord MR imaging protocol includes sagittal T1-weighted and proton attenuation, STIR or phase-sensitive inversion recovery, axial T2- or T2*-weighted imaging through suspicious lesions, and, in some cases, postcontrast gadolinium-enhanced T1-weighted imaging. The clinical question being addressed should be provided in the requisition for the MR imaging. The radiology report should be descriptive, with results referenced to previous studies. MR imaging studies should be permanently retained and available. The current revision incorporates new clinical information and imaging techniques that have become more available. PMID:26564433

  9. The effect of static scanning and mobility training on mobility in people with hemianopia after stroke: A randomized controlled trial comparing standardized versus non-standardized treatment protocols

    Science.gov (United States)

    2011-01-01

    Background Visual loss following stroke impacts significantly on activities of daily living and is an independent risk factor for becoming dependent. Routinely, allied health clinicians provide training for visual field loss, mainly with eye movement based therapy. The effectiveness of the compensatory approach to rehabilitation remains inconclusive largely due to difficulty in validating functional outcome with the varied type and dosage of therapy received by an individual patient. This study aims to determine which treatment is more effective, a standardized approach or individualized therapy in patients with homonymous hemianopia post stroke. Methods/Design This study is a double-blind randomized controlled, multicenter trial. A standardised scanning rehabilitation program (Neuro Vision Technology (NVT) program) of 7 weeks at 3 times per week, is compared to individualized therapy recommended by clinicians. Discussion The results of the trial will provide information that could potentially inform the allocation of resources in visual rehabilitation post stroke. Trial Registration Australia and New Zealand Clinical Trials Register (ANZCTR): ACTRN12610000494033 PMID:21767413

  10. The effect of static scanning and mobility training on mobility in people with hemianopia after stroke: A randomized controlled trial comparing standardized versus non-standardized treatment protocols

    Directory of Open Access Journals (Sweden)

    George Stacey

    2011-07-01

    Full Text Available Abstract Background Visual loss following stroke impacts significantly on activities of daily living and is an independent risk factor for becoming dependent. Routinely, allied health clinicians provide training for visual field loss, mainly with eye movement based therapy. The effectiveness of the compensatory approach to rehabilitation remains inconclusive largely due to difficulty in validating functional outcome with the varied type and dosage of therapy received by an individual patient. This study aims to determine which treatment is more effective, a standardized approach or individualized therapy in patients with homonymous hemianopia post stroke. Methods/Design This study is a double-blind randomized controlled, multicenter trial. A standardised scanning rehabilitation program (Neuro Vision Technology (NVT program of 7 weeks at 3 times per week, is compared to individualized therapy recommended by clinicians. Discussion The results of the trial will provide information that could potentially inform the allocation of resources in visual rehabilitation post stroke. Trial Registration Australia and New Zealand Clinical Trials Register (ANZCTR: ACTRN12610000494033

  11. A Review of Communications Protocol for Intelligent Remote Terminal Unit Development

    Directory of Open Access Journals (Sweden)

    Mohd Ruddin Ab. Ghani

    2013-11-01

    Full Text Available This paper reviewed all the possible interfacing communication protocols for remote terminal unit (RTU. Supervisory Control and Data Acquisition (SCADA system is a central station that can communicate with other network using the protocol. Fundamentally, the architectures of all networks are based on the seven layers of open system interconnection (OSI and International Standard Organization (ISO. The objective of designing the protocols is to check the status of all the input and output field devices and send the report according to that status. The corresponding protocol and communication parameters between the connecting devices will be included in designing a complex SCADA system. The available protocols to develop the communication of RTU are Modbus/ASCII, distributed network protocol (DNP3, controller area network (CAN, International Electro-technical Commission (IEC 60870, transmission control protocol/internet protocol (TCP/IP.

  12. Comparison of size modulation and conventional standard automated perimetry with the 24-2 test protocol in glaucoma patients

    Science.gov (United States)

    Hirasawa, Kazunori; Shoji, Nobuyuki; Kasahara, Masayuki; Matsumura, Kazuhiro; Shimizu, Kimiya

    2016-05-01

    This prospective randomized study compared test results of size modulation standard automated perimetry (SM-SAP) performed with the Octopus 600 and conventional SAP (C-SAP) performed with the Humphrey Field Analyzer (HFA) in glaucoma patients. Eighty-eight eyes of 88 glaucoma patients underwent SM-SAP and C-SAP tests with the Octopus 600 24-2 Dynamic and HFA 24-2 SITA-Standard, respectively. Fovea threshold, mean defect, and square loss variance of SM-SAP were significantly correlated with the corresponding C-SAP indices (P < 0.001). The false-positive rate was slightly lower, and false-negative rate slightly higher, with SM-SAP than C-SAP (P = 0.002). Point-wise threshold values obtained with SM-SAP were moderately to strongly correlated with those obtained with C-SAP (P < 0.001). The correlation coefficients of the central zone were significantly lower than those of the middle to peripheral zone (P = 0.031). The size and depth of the visual field (VF) defect were smaller (P = 0.039) and greater (P = 0.043), respectively, on SM-SAP than on C-SAP. Although small differences were observed in VF sensitivity in the central zone, the defect size and depth and the reliability indices between SM-SAP and C-SAP, global indices of the two testing modalities were well correlated.

  13. INTERGROWTH-21st Gestational Dating and Fetal and Newborn Growth Standards in Peri-Urban Nairobi, Kenya: Quasi-Experimental Implementation Study Protocol.

    Science.gov (United States)

    Millar, Kathryn; Patel, Suha; Munson, Meghan; Vesel, Linda; Subbiah, Shalini; Jones, Rachel M; Little, Sarah; Papageorghiou, Aris T; Villar, Jose; Wegner, Mary Nell; Pearson, Nick; Muigai, Faith; Ongeti, Catherine; Langer, Ana

    2018-06-22

    The burden of preterm birth, fetal growth impairment, and associated neonatal deaths disproportionately falls on low- and middle-income countries where modern obstetric tools are not available to date pregnancies and monitor fetal growth accurately. The INTERGROWTH-21 st gestational dating, fetal growth monitoring, and newborn size at birth standards make this possible. To scale up the INTERGROWTH-21 st standards, it is essential to assess the feasibility and acceptability of their implementation and their effect on clinical decision-making in a low-resource clinical setting. This study protocol describes a pre-post, quasi-experimental implementation study of the standards at Jacaranda Health, a maternity hospital in peri-urban Nairobi, Kenya. All women with viable fetuses receiving antenatal and delivery services, their resulting newborns, and the clinicians caring for them from March 2016 to March 2018 are included. The study comprises a 12-month preimplementation phase, a 12-month implementation phase, and a 5-month post-implementation phase to be completed in August 2018. Quantitative clinical and qualitative data collected during the preimplementation and implementation phases will be assessed. A clinician survey was administered eight months into the implementation phase, month 20 of the study. Implementation outcomes include quantitative and qualitative analyses of feasibility, acceptability, adoption, appropriateness, fidelity, and penetration of the standards. Clinical outcomes include appropriateness of referral and effect of the standards on clinical care and decision-making. Descriptive analyses will be conducted, and comparisons will be made between pre- and postimplementation outcomes. Qualitative data will be analyzed using thematic coding and compared across time. The study was approved by the Amref Ethics and Scientific Review Committee (Kenya) and the Harvard University Institutional Review Board. Study results will be shared with stakeholders

  14. Toward a standardized investigation protocol in sudden unexpected deaths in infancy in South Africa: a multicenter study of medico-legal investigation procedures and outcomes.

    Science.gov (United States)

    du Toit-Prinsloo, Lorraine; Dempers, Johan; Verster, Janette; Hattingh, Christa; Nel, Hestelle; Brandt, V D; Jordaan, Joyce; Saayman, Gert

    2013-09-01

    South Africa manifests a socio-economic dichotomy that shows features of both a developed and developing country. As a result of this, areas exist where a lack of resources and expertise prevents the implementation of a highly standardized protocol for the investigation of sudden and unexpected deaths in infants (SUDI). Although the medico-legal mortuaries attached to academic centers have the capacity to implement standardized protocols, a previous study conducted at two large medico-legal mortuaries indicated otherwise. This study also revealed that the exact number and incidence of sudden infant death syndrome (SIDS) cases was unknown. These findings prompted a multicenter study of the medico-legal investigation procedures and outcomes in five academic centers in South Africa. A retrospective case audit was conducted for a 5-year period (2005-2009) at medico-legal laboratories attached to universities in Bloemfontein, Cape Town-Tygerberg, Durban, Johannesburg, and Pretoria. The total case load as well as the total number of infants younger than 1 year of age admitted to these mortuaries was documented. The case files on all infants younger than 1 year of age who were admitted as sudden and unexpected or unexplained deaths were included in the study population. Data collected on the target population included demographic details, the nature and scope of the post-mortem examinations, as well as the final outcome (cause of death). A total case load of 80,399 cases were admitted to the mortuaries over the 5 year period with a total of 3,295 (6.5 %) infants. In the infant group, 591 (0.7 %) died from non-natural causes and 2,704 (3.3 %) cases of sudden, unexpected and/or unexplained deaths in infants were admitted and included in the detailed case analysis study. One hundred and ninety-nine babies were between 0 and 7 days of age and 210 babies between 8 and 30 days. The remaining 2,295 infants were between 1 month and 12 months of age. Death scene investigation was

  15. Depth (Standard Deviation) Layer used to identify, delineate and classify moderate-depth benthic habitats around St. John, USVI

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Standard deviation of depth was calculated from the bathymetry surface for each cell using the ArcGIS Spatial Analyst Focal Statistics "STD" parameter. Standard...

  16. Validation of a standard forensic anthropology examination protocol by measurement of applicability and reliability on exhumed and archive samples of known biological attribution.

    Science.gov (United States)

    Francisco, Raffaela Arrabaça; Evison, Martin Paul; Costa Junior, Moacyr Lobo da; Silveira, Teresa Cristina Pantozzi; Secchieri, José Marcelo; Guimarães, Marco Aurelio

    2017-10-01

    Forensic anthropology makes an important contribution to human identification and assessment of the causes and mechanisms of death and body disposal in criminal and civil investigations, including those related to atrocity, disaster and trafficking victim identification. The methods used are comparative, relying on assignment of questioned material to categories observed in standard reference material of known attribution. Reference collections typically originate in Europe and North America, and are not necessarily representative of contemporary global populations. Methods based on them must be validated when applied to novel populations. This study describes the validation of a standardized forensic anthropology examination protocol by application to two contemporary Brazilian skeletal samples of known attribution. One sample (n=90) was collected from exhumations following 7-35 years of burial and the second (n=30) was collected following successful investigations following routine case work. The study presents measurement of (1) the applicability of each of the methods: used and (2) the reliability with which the biographic parameters were assigned in each case. The results are discussed with reference to published assessments of methodological reliability regarding sex, age and-in particular-ancestry estimation. Copyright © 2017 Elsevier B.V. All rights reserved.

  17. Comparison of test results in the evaluation of the WSF of several jet fuels using the standardized aquatic microcosm and the mixed flask culture protocols

    International Nuclear Information System (INIS)

    Landis, W.G.; Matthews, R.A.; Markiewicz, A.J.; Matthews, G.B.

    1993-01-01

    The water soluble fraction of the turbine fuels Jet-A, JP-4 and JP-8 have been examines as stressors for two microcosm protocols, the standardized aquatic microcosm (SAM) and the mixed flask culture (MFC). The SAM is a 3 L system inoculated with standard cultures of algae, zooplankton, bacteria, protozoa. In contrast, the MFC is 1 L and is inoculated with a complex mixture of organisms derived from a natural source. Analysis of the organism counts and physical data were conducted using conventional and newly derived multivariate methods. Physical parameters, such as pH and oxygen metabolism, were often not as sensitive as species and bacterial counts. Like the SAM system, species numbers and other variables that determined clusters varied among sampling dates. Compared to the larger yet simpler system, the MFC exhibits more violent dynamics and is more likely to become catastrophically fixated, as in systems dominated by cyanobacteria. The combination of greater diversity and smaller volume may contribute to the volatile or chaotic dynamics of the MFC system

  18. Cranial CT with 64-, 16-, 4- and single-slice CT systems-comparison of image quality and posterior fossa artifacts in routine brain imaging with standard protocols

    Energy Technology Data Exchange (ETDEWEB)

    Ertl-Wagner, Birgit; Eftimov, Lara; Becker, Christoph; Reiser, Maximilian [University of Munich, Grosshadern (Germany). Institute of Clinical Radiology; Blume, Jeffrey; Cormack, Jean [Brown University, Center for Statistical Sciences, Providence, RI (United States); Bruening, Roland; Brueckmann, Hartmut [University of Munich, Grosshadern (Germany). Department of Neuroradiology

    2008-08-15

    Posterior fossa artifacts constitute a characteristic limitation of cranial CT. To identify practical benefits and drawbacks of newer CT systems with reduced collimation in routine cranial imaging, we aimed to investigate image quality, posterior fossa artifacts and parenchymal delineation in non-enhanced CT (NECT) with 1-, 4-, 16- and 64-slice scanners using standard scan protocols. We prospectively enrolled 25 consecutive patients undergoing NECT on a 64-slice CT. Three groups with 25 patients having undergone NECT on 1-, 4- and 16-slice CT machines were matched regarding age and sex. Standard routine CT parameters were used on each CT system with helical acquisition in the posterior fossa; the parameters varied regarding collimation and radiation dose. Three blinded readers independently assessed the cases regarding image quality, infra- and supratentorial artifacts and delineation of brain parenchymal structures on a five-point ordinal scale. Reading orders were randomized. A proportional odds model that accounted for the correlated nature of the data was fit using generalized estimating equations. Posterior fossa artifacts were significantly reduced, and the delineation of infratentorial brain structures was significantly improved with the thinner collimation used for the newer CT systems (p<0.001). No significant differences were observed for midbrain structures (p>0.5). The thinner collimation available on modern CT systems leads to reduced posterior fossa artifacts and to a better delineation of brain parenchyma in the posterior fossa. (orig.)

  19. A cross-platform survey of CT image quality and dose from routine abdomen protocols and a method to systematically standardize image quality

    International Nuclear Information System (INIS)

    Favazza, Christopher P; Duan, Xinhui; Zhang, Yi; Yu, Lifeng; Leng, Shuai; Kofler, James M; Bruesewitz, Michael R; McCollough, Cynthia H

    2015-01-01

    Through this investigation we developed a methodology to evaluate and standardize CT image quality from routine abdomen protocols across different manufacturers and models. The influence of manufacturer-specific automated exposure control systems on image quality was directly assessed to standardize performance across a range of patient sizes. We evaluated 16 CT scanners across our health system, including Siemens, GE, and Toshiba models. Using each practice’s routine abdomen protocol, we measured spatial resolution, image noise, and scanner radiation output (CTDI vol ). Axial and in-plane spatial resolutions were assessed through slice sensitivity profile (SSP) and modulation transfer function (MTF) measurements, respectively. Image noise and CTDI vol values were obtained for three different phantom sizes. SSP measurements demonstrated a bimodal distribution in slice widths: an average of 6.2  ±  0.2 mm using GE’s ‘Plus’ mode reconstruction setting and 5.0  ±  0.1 mm for all other scanners. MTF curves were similar for all scanners. Average spatial frequencies at 50%, 10%, and 2% MTF values were 3.24  ±  0.37, 6.20  ±  0.34, and 7.84  ±  0.70 lp cm −1 , respectively. For all phantom sizes, image noise and CTDI vol varied considerably: 6.5–13.3 HU (noise) and 4.8–13.3 mGy (CTDI vol ) for the smallest phantom; 9.1–18.4 HU and 9.3–28.8 mGy for the medium phantom; and 7.8–23.4 HU and 16.0–48.1 mGy for the largest phantom. Using these measurements and benchmark SSP, MTF, and image noise targets, CT image quality can be standardized across a range of patient sizes. (paper)

  20. Communications standards

    CERN Document Server

    Stokes, A V

    1986-01-01

    Communications Standards deals with the standardization of computer communication networks. This book examines the types of local area networks (LANs) that have been developed and looks at some of the relevant protocols in more detail. The work of Project 802 is briefly discussed, along with a protocol which has developed from one of the LAN standards and is now a de facto standard in one particular area, namely the Manufacturing Automation Protocol (MAP). Factors that affect the usage of networks, such as network management and security, are also considered. This book is divided into three se

  1. Protocol for Communication Networking for Formation Flying

    Science.gov (United States)

    Jennings, Esther; Okino, Clayton; Gao, Jay; Clare, Loren

    2009-01-01

    An application-layer protocol and a network architecture have been proposed for data communications among multiple autonomous spacecraft that are required to fly in a precise formation in order to perform scientific observations. The protocol could also be applied to other autonomous vehicles operating in formation, including robotic aircraft, robotic land vehicles, and robotic underwater vehicles. A group of spacecraft or other vehicles to which the protocol applies could be characterized as a precision-formation- flying (PFF) network, and each vehicle could be characterized as a node in the PFF network. In order to support precise formation flying, it would be necessary to establish a corresponding communication network, through which the vehicles could exchange position and orientation data and formation-control commands. The communication network must enable communication during early phases of a mission, when little positional knowledge is available. Particularly during early mission phases, the distances among vehicles may be so large that communication could be achieved only by relaying across multiple links. The large distances and need for omnidirectional coverage would limit communication links to operation at low bandwidth during these mission phases. Once the vehicles were in formation and distances were shorter, the communication network would be required to provide high-bandwidth, low-jitter service to support tight formation-control loops. The proposed protocol and architecture, intended to satisfy the aforementioned and other requirements, are based on a standard layered-reference-model concept. The proposed application protocol would be used in conjunction with conventional network, data-link, and physical-layer protocols. The proposed protocol includes the ubiquitous Institute of Electrical and Electronics Engineers (IEEE) 802.11 medium access control (MAC) protocol to be used in the datalink layer. In addition to its widespread and proven use in

  2. Trade restrictions as a means of enforcing compliance with international environmental law. Montreal Protocol on Substances that Deplete the Ozone Layer

    International Nuclear Information System (INIS)

    Lang, W.

    1996-01-01

    The contribution reviews primarily Art. 4 of the Montreal Protocol and its efficiency for enforcing compliance with obligations under international environmental law and discusses aspects of possible conflicts with GATT law. (CB)

  3. A Lightweight Protocol for Secure Video Streaming.

    Science.gov (United States)

    Venčkauskas, Algimantas; Morkevicius, Nerijus; Bagdonas, Kazimieras; Damaševičius, Robertas; Maskeliūnas, Rytis

    2018-05-14

    The Internet of Things (IoT) introduces many new challenges which cannot be solved using traditional cloud and host computing models. A new architecture known as fog computing is emerging to address these technological and security gaps. Traditional security paradigms focused on providing perimeter-based protections and client/server point to point protocols (e.g., Transport Layer Security (TLS)) are no longer the best choices for addressing new security challenges in fog computing end devices, where energy and computational resources are limited. In this paper, we present a lightweight secure streaming protocol for the fog computing "Fog Node-End Device" layer. This protocol is lightweight, connectionless, supports broadcast and multicast operations, and is able to provide data source authentication, data integrity, and confidentiality. The protocol is based on simple and energy efficient cryptographic methods, such as Hash Message Authentication Codes (HMAC) and symmetrical ciphers, and uses modified User Datagram Protocol (UDP) packets to embed authentication data into streaming data. Data redundancy could be added to improve reliability in lossy networks. The experimental results summarized in this paper confirm that the proposed method efficiently uses energy and computational resources and at the same time provides security properties on par with the Datagram TLS (DTLS) standard.

  4. Pragmatic, consensus-based minimum standards and structured interview to guide the selection and development of cancer support group leaders: a protocol paper.

    Science.gov (United States)

    Pomery, Amanda; Schofield, Penelope; Xhilaga, Miranda; Gough, Karla

    2017-06-30

    Across the globe, peer support groups have emerged as a community-led approach to accessing support and connecting with others with cancer experiences. Little is known about qualities required to lead a peer support group or how to determine suitability for the role. Organisations providing assistance to cancer support groups and their leaders are currently operating independently, without a standard national framework or published guidelines. This protocol describes the methods that will be used to generate pragmatic consensus-based minimum standards and an accessible structured interview with user manual to guide the selection and development of cancer support group leaders. We will: (A) identify and collate peer-reviewed literature that describes qualities of support group leaders through a systematic review; (B) content analyse eligible documents for information relevant to requisite knowledge, skills and attributes of group leaders generally and specifically to cancer support groups; (C) use an online reactive Delphi method with an interdisciplinary panel of experts to produce a clear, suitable, relevant and appropriate structured interview comprising a set of agreed questions with behaviourally anchored rating scales; (D) produce a user manual to facilitate standard delivery of the structured interview; (E) pilot the structured interview to improve clinical utility; and (F) field test the structured interview to develop a rational scoring model and provide a summary of existing group leader qualities. The study is approved by the Department Human Ethics Advisory Group of The University of Melbourne. The study is based on voluntary participation and informed written consent, with participants able to withdraw at any time. The results will be disseminated at research conferences and peer review journals. Presentations and free access to the developed structured interview and user manual will be available to cancer agencies. © Article author(s) (or their

  5. Mac protocols for wireless sensor network (wsn): a comparative study

    International Nuclear Information System (INIS)

    Arshad, J.; Akram, Q.; Saleem, Y.

    2014-01-01

    Data communication between nodes is carried out under Medium Access Control (MAC) protocol which is defined at data link layer. The MAC protocols are responsible to communicate and coordinate between nodes according to the defined standards in WSN (Wireless Sensor Networks). The design of a MAC protocol should also address the issues of energy efficiency and transmission efficiency. There are number of MAC protocols that exist in the literature proposed for WSN. In this paper, nine MAC protocols which includes S-MAC, T-MAC, Wise-MAC, Mu-MAC, Z-MAC, A-MAC, D-MAC, B-MAC and B-MAC+ for WSN have been explored, studied and analyzed. These nine protocols are classified in contention based and hybrid (combination of contention and schedule based) MAC protocols. The goal of this comparative study is to provide a basis for MAC protocols and to highlight different mechanisms used with respect to parameters for the evaluation of energy and transmission efficiency in WSN. This study also aims to give reader a better understanding of the concepts, processes and flow of information used in these MAC protocols for WSN. A comparison with respect to energy reservation scheme, idle listening avoidance, latency, fairness, data synchronization, and throughput maximization has been presented. It was analyzed that contention based MAC protocols are less energy efficient as compared to hybrid MAC protocols. From the analysis of contention based MAC protocols in term of energy consumption, it was being observed that protocols based on preamble sampling consume lesser energy than protocols based on static or dynamic sleep schedule. (author)

  6. Simultaneous validation of the Grandway MD2301 digital automatic blood pressure monitor by the British Hypertension Society and the Association for the Advancement of Medical Instrumentation/the International Organization for Standardization protocols.

    Science.gov (United States)

    Huang, Jinhua; Wang, Yun; Liu, Zhaoying; Wang, Yuling

    2017-02-01

    The aim of this study was to determine the accuracy of the Grandway MD2301 digital automatic blood pressure monitor by the British Hypertension Society (BHS) and the Association for the Advancement of Medical Instrumentation (AAMI)/the International Organization for Standardization (ISO) protocols. A total of 85 participants were included for evaluation based on the requirements of the BHS and the AAMI/ISO protocols. The validation procedure and data analysis followed the protocols precisely. The device achieved A/A grading for the BHS protocol and maintained A/A grading throughout the low, medium and high blood pressure ranges. The device also fulfilled the requirement of the AAMI/ISO protocol with device-observer differences of -0.9±5.6 and 0.8±5.2 mmHg for systolic and diastolic blood pressure, respectively, for criterion 1, and -0.9±4.7 and 0.8±4.2 mmHg, respectively, for criterion 2. The Grandway MD2301 digital automatic blood pressure monitor achieved A/A grade of the BHS protocol and passed the requirements of the AAMI/ISO protocol in adults.

  7. Low incidence of clonality in cold water corals revealed through the novel use of a standardized protocol adapted to deep sea sampling

    Science.gov (United States)

    Becheler, Ronan; Cassone, Anne-Laure; Noël, Philippe; Mouchel, Olivier; Morrison, Cheryl L.; Arnaud-Haond, Sophie

    2017-11-01

    Sampling in the deep sea is a technical challenge, which has hindered the acquisition of robust datasets that are necessary to determine the fine-grained biological patterns and processes that may shape genetic diversity. Estimates of the extent of clonality in deep-sea species, despite the importance of clonality in shaping the local dynamics and evolutionary trajectories, have been largely obscured by such limitations. Cold-water coral reefs along European margins are formed mainly by two reef-building species, Lophelia pertusa and Madrepora oculata. Here we present a fine-grained analysis of the genotypic and genetic composition of reefs occurring in the Bay of Biscay, based on an innovative deep-sea sampling protocol. This strategy was designed to be standardized, random, and allowed the georeferencing of all sampled colonies. Clonal lineages discriminated through their Multi-Locus Genotypes (MLG) at 6-7 microsatellite markers could thus be mapped to assess the level of clonality and the spatial spread of clonal lineages. High values of clonal richness were observed for both species across all sites suggesting a limited occurrence of clonality, which likely originated through fragmentation. Additionally, spatial autocorrelation analysis underlined the possible occurrence of fine-grained genetic structure in several populations of both L. pertusa and M. oculata. The two cold-water coral species examined had contrasting patterns of connectivity among canyons, with among-canyon genetic structuring detected in M. oculata, whereas L. pertusa was panmictic at the canyon scale. This study exemplifies that a standardized, random and georeferenced sampling strategy, while challenging, can be applied in the deep sea, and associated benefits outlined here include improved estimates of fine grained patterns of clonality and dispersal that are comparable across sites and among species.

  8. A Cross-Layer Wireless Sensor Network Energy-Efficient Communication Protocol for Real-Time Monitoring of the Long-Distance Electric Transmission Lines

    Directory of Open Access Journals (Sweden)

    Jun Yu

    2015-01-01

    Full Text Available Optimization of energy consumption in Wireless Sensor Network (WSN nodes has become a critical link that constrains the engineering application of the smart grid due to the fact that the smart grid is characterized by long-distance transmission in a special environment. The paper proposes a linear hierarchical network topological structure specific to WSN energy conservation in environmental monitoring of the long-distance electric transmission lines in the smart grid. Based on the topological structural characteristics and optimization of network layers, the paper also proposes a Topological Structure be Layered Configurations (TSLC routing algorithm to improve the quality of WSN data transmission performance. Coprocessing of the network layer and the media access control (MAC layer is achieved by using the cross-layer design method, accessing the status for the nodes in the network layer and obtaining the status of the network nodes of the MAC layer. It efficiently saves the energy of the whole network, improves the quality of the network service performance, and prolongs the life cycle of the network.

  9. Validation of the G.LAB MD2200 wrist blood pressure monitor according to the European Society of Hypertension, the British Hypertension Society, and the International Organization for Standardization Protocols.

    Science.gov (United States)

    Liu, Ze-Yu; Zhang, Qing-Han; Ye, Xiao-Lei; Liu, Da-Peng; Cheng, Kang; Zhang, Chun-Hai; Wan, Yi

    2017-04-01

    To validate the G.LAB MD2200 automated wrist blood pressure (BP) monitors according to the European Society of Hypertension International Protocol (ESH-IP) revision 2010, the British Hypertension Society (BHS), and the International Organization for Standardization (ISO) 81060-2:2013 protocols. The device was assessed on 33 participants according to the ESH requirements and was then tested on 85 participants according to the BHS and ISO 81060-2:2013 criteria. The validation procedures and data analysis followed the protocols precisely. The G.LAB MD2200 devices passed all parts of ESH-IP revision 2010 for both systolic and diastolic BP, with a device-observer difference of 2.15±5.51 and 1.51±5.16 mmHg, respectively. The device achieved A/A grading for the BHS protocol and it also fulfilled the criteria of ISO 81060-2:2013, with mean differences of systolic and diastolic BP between the device and the observer of 2.19±5.21 and 2.11±4.70 mmHg, respectively. The G.LAB MD2200 automated wrist BP monitor passed the ESH-IP revision 2010 and the ISO 81060-2:2013 protocol, and achieved the A/A grade of the BHS protocol, which can be recommended for self-measurement in the general population.

  10. Protocol Fuel Mix reporting

    International Nuclear Information System (INIS)

    2002-07-01

    The protocol in this document describes a method for an Electricity Distribution Company (EDC) to account for the fuel mix of electricity that it delivers to its customers, based on the best available information. Own production, purchase and sale of electricity, and certificates trading are taken into account. In chapter 2 the actual protocol is outlined. In the appendixes additional (supporting) information is given: (A) Dutch Standard Fuel Mix, 2000; (B) Calculation of the Dutch Standard fuel mix; (C) Procedures to estimate and benchmark the fuel mix; (D) Quality management; (E) External verification; (F) Recommendation for further development of the protocol; (G) Reporting examples

  11. Multichannel MAC Layer In Mobile Ad—Hoc Network

    Science.gov (United States)

    Logesh, K.; Rao, Samba Siva

    2010-11-01

    This paper we presented the design objectives and technical challenges in Multichannel MAC protocols in Mobile Ad-hoc Network. In IEEE 802.11 a/b/g standards allow use of multiple channels, only a single channel is popularly used, due to the lack of efficient protocols that enable use of Multiple Channels. Even though complex environments in ad hoc networks require a combined control of physical (PHY) and medium access control (MAC) layers resources in order to optimize performance. And also we discuss the characteristics of cross-layer frame and give a multichannel MAC approach.

  12. Definition of a Standard Protocol to Determine the Growth Potential of Listeria Monotgenes and Yersinia Enterocolitica in Pork Sausage Produced in Abruzzo Region, Italy.

    Science.gov (United States)

    Sperandii, Anna Franca; Neri, Diana; Romantini, Romina; Santarelli, Gino Angelo; Prencipe, Vincenza

    2015-11-02

    Pork meat products consumed raw or after a short period of fermentation can be considered at risk for food safety. Sausages (fresh sausage made from pork meat) are produced in several Italian regions, with variation in ingredients. In some Italian Regions, including Abruzzo, these products are frequently consumed raw or undercooked, after a variable period of fermentation. The European Community food regulation promotes the use of challenge tests to determine safety levels. This study is aimed to ensure safety of Abruzzo's sausages, compared with growth potential (δ) of Listeria monocytogenes and Yersinia enterocolitica , and also aims to define an experimental standard protocol document to carry out challenge tests. Guidelines classify ready-to-eat foods in categories that are able to support (δ>0.5 log 10 ufc/g) and not support (δ≤0.5 log 10 ufc/g) the growth of Listeria monocytogenes. The products were manufactured according to traditional recipes and were contaminated in laboratory. Results from the experiment yielded information useful to assess the ability of these products to support the growth of pathogenic microorganisms. The batches of sausages were stored at 8, 12, 18 and 20°C to get statistical evaluation. The results showed that, despite the conditioning of the storage temperature and the level of water activity, both organisms remain in the product in concentrations similar to those leading or being able to increase its charge. In particular, the period of greatest consumption of this product (7/8 days of preparation) corresponds to the period of greatest growth of pathogenic microorganisms studied, except for those stored at a temperature of 8°C, which are safer for the consumer.

  13. Using fMRI to Detect Activation of the Cortical and Subcortical Auditory Centers: Development of a Standard Protocol for a Conventional 1.5-T MRI Scanner

    International Nuclear Information System (INIS)

    Tae, Woo Suk; Kim, Sam Soo; Lee, Kang Uk; Lee, Seung Hwan; Nam, Eui Cheol; Choi, Hyun Kyung

    2009-01-01

    We wanted to develop a standard protocol for auditory functional magnetic resonance imaging (fMRI) for detecting blood oxygenation level-dependent (BOLD) responses at the cortical and subcortical auditory centers with using a 1.5-T MRI scanner. Fourteen normal volunteers were enrolled in the study. The subjects were stimulated by four repetitions of 32 sec each with broadband white noise and silent period blocks as a run (34 echo planar images [EPIs]). Multiple regression analysis for the individual analysis and one-sample t-tests for the group analysis were applied (FDR, p <0.05). The auditory cortex was activated in most of the volunteers (left 100% and right 92.9% at an uncorrected p value <0.05, and left 92.9% and right 92.9% at an uncorreced p value <0.01). The cochlear nuclei (100%, 85.7%), inferior colliculi (71.4%, 64.3%), medial geniculate bodies (64.3%, 35.7%) and superior olivary complexes (35.7%, 35.7%) showed significant BOLD responses at uncorrected p values of <0.05 and p <0.01, respectively. On the group analysis, the cortical and subcortical auditory centers showed significant BOLD responses (FDR, p <0.05), except for the superior olivary complex. The signal intensity time courses of the auditory centers showed biphasic wave forms. We successfully visualized BOLD responses at the cortical and subcortical auditory centers using appropriate sound stimuli and an image acquisition method with a 1.5-T MRI scanner

  14. Energy Efficient Network Protocols for Wireless and Mobile Networks

    National Research Council Canada - National Science Library

    Sivalingam, Krishna

    2001-01-01

    ... (also called power aware) network protocols for wireless and mobile networks. Battery power limitations are a very serious concern, and it is essential to study energy efficient protocol design at different layers of the network protocol stack...

  15. An Improved 6LoWPAN Hierarchical Routing Protocol

    Directory of Open Access Journals (Sweden)

    Xue Li

    2015-10-01

    Full Text Available IETF 6LoWPAN working group is engaged in the IPv6 protocol stack research work based on IEEE802.15.4 standard. In this working group, the routing protocol is one of the important research contents. In the 6LoWPAN, HiLow is a well-known layered routing protocol. This paper puts forward an improved hierarchical routing protocol GHiLow by improving HiLow parent node selection and path restoration strategy. GHiLow improves the parent node selection by increasing the choice of parameters. Simutaneously, it also improves path recovery by analysing different situations to recovery path. Therefore, GHiLow contributes to the ehancement of network performance and the decrease of network energy consumption.

  16. An investigation into the nutritional status of patients receiving an Enhanced Recovery After Surgery (ERAS) protocol versus standard care following Oesophagectomy.

    Science.gov (United States)

    Benton, Katie; Thomson, Iain; Isenring, Elisabeth; Mark Smithers, B; Agarwal, Ekta

    2018-06-01

    Enhanced Recovery After Surgery (ERAS) protocols have been effectively expanded to various surgical specialities including oesophagectomy. Despite nutrition being a key component, actual nutrition outcomes and specific guidelines are lacking. This cohort comparison study aims to compare nutritional status and adherence during implementation of a standardised post-operative nutritional support protocol, as part of ERAS, compared to those who received usual care. Two groups of patients undergoing resection of oesophageal cancer were studied. Group 1 (n = 17) underwent oesophagectomy between Oct 2014 and Nov 2016 during implementation of an ERAS protocol. Patients in group 2 (n = 16) underwent oesophagectomy between Jan 2011 and Dec 2012 prior to the implementation of ERAS. Demographic, nutritional status, dietary intake and adherence data were collected. Ordinal data was analysed using independent t tests, and categorical data using chi-square tests. There was no significant difference in nutrition status, dietary intake or length of stay following implementation of an ERAS protocol. Malnutrition remained prevalent in both groups at day 42 post surgery (n = 10, 83% usual care; and n = 9, 60% ERAS). A significant difference was demonstrated in adherence with earlier initiation of oral free fluids (p nutrition protocol, within an ERAS framework, results in earlier transition to oral intake; however, malnutrition remains prevalent post surgery. Further large-scale studies are warranted to examine individualised decision-making regarding nutrition support within an ERAS protocol.

  17. Subdissociative intranasal ketamine plus standard pain therapy versus standard pain therapy in the treatment of paediatric sickle cell disease vaso-occlusive crises in resource-limited settings: study protocol for a randomised controlled trial.

    Science.gov (United States)

    Young, James R; Sawe, Hendry Robert; Mfinanga, Juma A; Nshom, Ernest; Helm, Ethan; Moore, Charity G; Runyon, Michael S; Reynolds, Stacy L

    2017-07-10

    Pediatric sickle cell disease, highly prevalent in sub-Saharan Africa, carries great morbidity and mortality risk. Limited resources and monitoring make management of acute vaso-occlusive crises challenging. This study aims to evaluate the efficacy and safety of subdissociative intranasal ketamine as a cheap, readily available and easily administered adjunct to standard pain therapy. We hypothesise that subdissociative, intranasal ketamine may significantly augment current approaches to pain management in resource-limited settings in a safe and cost-effective manner. This is a multicentred, randomised, double-blind, placebo-controlled trial enrolling children 4-16 years of age with sickle cell disease and painful vaso-occlusive pain crises. Study sites include two sub-Saharan teaching and referral hospitals with acute intake areas. All patients receive standard analgesic therapy during evaluation. Patients randomised to the treatment arm receive 1 mg/kg intranasal ketamine at onset of therapy, while placebo arm participants receive volume-matched intranasal normal saline. All participants and clinical staff are blinded to the treatment allocation. Data will be analysed on an intention-to-treat basis. Primary endpoints are changes in self-report pain scales (Faces Pain Scale-Revised) at 30, 60 and 120 minutes and rates of adverse events. Secondary endpoints include hospital length of stay, total analgesia use and quality of life assessment 2-3 weeks postintervention. The research methods for this study have been approved by the Cameroon Baptist Convention Health Board Institutional Review Board (IRB2015-07), the Tanzanian National Institute for Medical Research (NIMR/HQ/R.8a/Vol. IX/2299), Muhimbili National Hospital IRB (MNH/IRB/I/2015/14) and the Tanzanian Food and Drugs Authority (TFDA0015/CTR/0015/9). Data reports will be provided to the Data and Safety Monitoring Board (DSMB) periodically throughout the study as well as all reports of adverse events. All

  18. The Network Protocol Analysis Technique in Snort

    Science.gov (United States)

    Wu, Qing-Xiu

    Network protocol analysis is a network sniffer to capture data for further analysis and understanding of the technical means necessary packets. Network sniffing is intercepted by packet assembly binary format of the original message content. In order to obtain the information contained. Required based on TCP / IP protocol stack protocol specification. Again to restore the data packets at protocol format and content in each protocol layer. Actual data transferred, as well as the application tier.

  19. Digital breast tomosynthesis plus synthesised images versus standard full-field digital mammography in population-based screening (TOSYMA): protocol of a randomised controlled trial.

    Science.gov (United States)

    Weigel, Stefanie; Gerss, Joachim; Hense, Hans-Werner; Krischke, Miriam; Sommer, Alexander; Czwoydzinski, Jörg; Lenzen, Horst; Kerschke, Laura; Spieker, Karin; Dickmaenken, Stefanie; Baier, Sonja; Urban, Marc; Hecht, Gerold; Heidinger, Oliver; Kieschke, Joachim; Heindel, Walter

    2018-05-14

    Development of digital breast tomosynthesis (DBT) provides a technology that generates three-dimensional data sets, thus reducing the pitfalls of overlapping breast tissue. Observational studies suggest that the combination of two-dimensional (2D) digital mammography and DBT increases diagnostic accuracy. However, because of duplicate exposure, this comes at the cost of an augmented radiation dose. This undesired adverse impact can be avoided by using synthesised 2D images reconstructed from the DBT data (s2D).We designed a diagnostic superiority trial on a high level of evidence with the aim of providing a comparison of screening efficacy parameters resulting from DBT+s2D versus the current screening standard 2D full-field digital mammography (FFDM) in a multicentre and multivendor setting on the basis of the quality-controlled, population-based, biennial mammography screening programme in Germany. 80 000 women in the eligible age 50-69 years attending the routine mammography screening programme and willing to participate in the TOSYMA trial will be assigned by 1:1 randomisation to either the intervention arm (DBT+s2D) or the control arm (FFDM) during a 12-month recruitment period in screening units of North Rhine-Westphalia and Lower Saxony. State cancer registries will provide the follow-up of interval cancers.Primary endpoints are the detection rate of invasive breast cancers at screening examination and the cumulative incidence of interval cancers in the 2 years after a negative examination. Secondary endpoints are the detection rate of ductal carcinoma in situ and of tumour size T1, the recall rate for assessment, the positive predictive value of recall and the cumulative 12-month incidence of interval cancers. An adaptive statistical design with one interim analysis provides the option to modify the design. This protocol has been approved by the local medical ethical committee (2016-132-f-S). Results will be submitted to international peer

  20. Bioremediation protocols

    National Research Council Canada - National Science Library

    Sheehan, David

    1997-01-01

    ..., .. . . . . .. ,. . . .. . . . . . . . .. . . . . .. . . .. . .. 3 2 Granular Nina Sludge Christiansen, Consortia lndra for Bioremediation, M. Mathrani, and Birgitte K. Ahring . 23 PART II PROTOCOLS...

  1. A Mac Protocol Implementation for Wireless Sensor Network

    Directory of Open Access Journals (Sweden)

    Jamila Bhar

    2015-01-01

    Full Text Available IEEE 802.15.4 is an important standard for Low Rate Wireless Personal Area Network (LRWPAN. The IEEE 802.15.4 presents a flexible MAC protocol that provides good efficiency for data transmission by adapting its parameters according to characteristics of different applications. In this research work, some restrictions of this standard are explained and an improvement of traffic efficiency by optimizing MAC layer is proposed. Implementation details for several blocks of communication system are carefully modeled. The protocol implementation is done using VHDL language. The analysis gives a full understanding of the behavior of the MAC protocol with regard to backoff delay, data loss probability, congestion probability, slot effectiveness, and traffic distribution for terminals. Two ideas are proposed and tested to improve efficiency of CSMA/CA mechanism for IEEE 802.15.4 MAC Layer. Primarily, we dynamically adjust the backoff exponent (BE according to queue level of each node. Secondly, we vary the number of consecutive clear channel assessment (CCA for packet transmission. We demonstrate also that slot compensation provided by the enhanced MAC protocol can greatly avoid unused slots. The results show the significant improvements expected by our approach among the IEEE 802.15.4 MAC standards. Synthesis results show also hardware performances of our proposed architecture.

  2. ATM and Internet protocol

    CERN Document Server

    Bentall, M; Turton, B

    1998-01-01

    Asynchronous Transfer Mode (ATM) is a protocol that allows data, sound and video being transferred between independent networks via ISDN links to be supplied to, and interpreted by, the various system protocols.ATM and Internet Protocol explains the working of the ATM and B-ISDN network for readers with a basic understanding of telecommunications. It provides a handy reference to everyone working with ATM who may not require the full standards in detail, but need a comprehensive guide to ATM. A substantial section is devoted to the problems of running IP over ATM and there is some discussion o

  3. Evaluation of the standard normal variate method for Laser-Induced Breakdown Spectroscopy data treatment applied to the discrimination of painting layers

    Science.gov (United States)

    Syvilay, D.; Wilkie-Chancellier, N.; Trichereau, B.; Texier, A.; Martinez, L.; Serfaty, S.; Detalle, V.

    2015-12-01

    Nowadays, Laser-Induced Breakdown Spectroscopy (LIBS) is frequently used for in situ analyses to identify pigments from mural paintings. Nonetheless, in situ analyses require a robust instrumentation in order to face to hard experimental conditions. This may imply variation of fluencies and thus inducing variation of LIBS signal, which degrades spectra and then results. Usually, to overcome these experimental errors, LIBS signal is processed. Signal processing methods most commonly used are the baseline subtraction and the normalization by using a spectral line. However, the latter suggests that this chosen element is a constant component of the material, which may not be the case in paint layers organized in stratigraphic layers. For this reason, it is sometimes difficult to apply this normalization. In this study, another normalization will be carried out to throw off these signal variations. Standard normal variate (SNV) is a normalization designed for these conditions. It is sometimes implemented in Diffuse Reflectance Infrared Fourier Transform Spectroscopy and in Raman Spectroscopy but rarely in LIBS. The SNV transformation is not newly applied on LIBS data, but for the first time the effect of SNV on LIBS spectra was evaluated in details (energy of laser, shot by shot, quantification). The aim of this paper is the quick visualization of the different layers of a stratigraphic painting sample by simple data representations (3D or 2D) after SNV normalization. In this investigation, we showed the potential power of SNV transformation to overcome undesired LIBS signal variations but also its limit of application. This method appears as a promising way to normalize LIBS data, which may be interesting for in-situ depth analyses.

  4. Sub-Transport Layer Coding

    DEFF Research Database (Denmark)

    Hansen, Jonas; Krigslund, Jeppe; Roetter, Daniel Enrique Lucani

    2014-01-01

    Packet losses in wireless networks dramatically curbs the performance of TCP. This paper introduces a simple coding shim that aids IP-layer traffic in lossy environments while being transparent to transport layer protocols. The proposed coding approach enables erasure correction while being...... oblivious to the congestion control algorithms of the utilised transport layer protocol. Although our coding shim is indifferent towards the transport layer protocol, we focus on the performance of TCP when ran on top of our proposed coding mechanism due to its widespread use. The coding shim provides gains...

  5. Delineation of upper urinary tract segments at MDCT urography in patients with extra-urinary mass lesions: retrospective comparison of standard and low-dose protocols for the excretory phase of imaging

    Energy Technology Data Exchange (ETDEWEB)

    Mueller-Lisse, Ulrike L. [University of Munich, Department of Urology, Munich (Germany); University of Munich Medical School, Department of Urology, Muenchen (Germany); Coppenrath, Eva M.; Meindl, Thomas; Degenhart, Christoph; Scherr, Michael K.; Reiser, Maximilian F.; Mueller-Lisse, Ullrich G. [University of Munich, Department of Radiology, Munich (Germany); Stief, Christian G. [University of Munich, Department of Urology, Munich (Germany)

    2011-02-15

    Excretory-phase CT urography (CTU) may replace excretory urography in patients without urinary tumors. However, radiation exposure is a concern. We retrospectively compared upper urinary tract (UUT) delineation in low-dose and standard CTU. CTU (1-2 phases, 120 KV, 4 x 2.5 mm, pitch 0.875, i.v. non-ionic contrast media, iodine 36 g) was obtained with standard (14 patients, n = 27 UUTs, average 175.6 mAs/slice, average delay 16.8 min) or low-dose (26 patients, n = 86 UUTs, 29 mAs/slice, average delay 19.6 min) protocols. UUT was segmented into intrarenal collecting system (IRCS), upper, middle, and lower ureter (UU,MU,LU). Two independent readers (R1,R2) graded UUT segments as 1-not delineated, 2-partially delineated, 3-completely delineated (noisy margins), 4-completely delineated (clear margins). Chi-square statistics were calculated for partial versus complete delineation and complete delineation (clear margins), respectively. Complete delineation of UUT was similar in standard and low-dose CTU (R1, p > 0.15; R2, p > 0.2). IRCS, UU, and MU clearly delineated similarly often in standard and low-dose CTU (R1, p > 0.25; R2, p > 0.1). LU clearly delineated more often in standard protocols (R1, 18/6 standard, 38/31 low-dose, p > 0.1; R2 18/6 standard, 21/48 low-dose, p < 0.05). Low-dose CTU sufficiently delineated course of UUT and may locate obstruction/dilation, but appears unlikely to find intraluminal LU lesions. (orig.)

  6. Protocol for the building construction process with regard to the implementation trajectory protocols EWN and EUN. Manual for commissioners, contractors, building management offices and energy efficiency standard advisors; Handleiding opnameprotocollen EWN en EUN. Voor opdrachtgevers, aannemers, bouwmanagementbureaus en EPN-adviseurs

    Energy Technology Data Exchange (ETDEWEB)

    Neeleman, J. [DWA installatie- en energieadvies, Duitslandweg 4, Postbus 274, 2410 AG Bodegraven (Netherlands)

    2013-04-15

    In the year 2012 it was foreseen to base the energy label for new buildings on the Energy Efficiency Coefficient (EPC in Dutch). This is a protocol for residential and utility buildings, with the aim to check whether and to what extent buildings were constructed according the EPC and to determine the realized EPC. In order to gain experience with the new protocols and the voluntary ventilation test the Protocol for the Energy Label for New Houses (EWN in Dutch) and the Protocol for the Energy Label for New Utility Buildings (EUN in Dutch) were conducted in 12 newly built housing projects and 5 projects in the utility building sector. With this manual you can realize energy efficient houses and/or utility buildings that meet the standards [Dutch] In het jaar 2012 was voorzien om het nieuwbouwlabel te baseren op de EPC (Energie Prestatie Coefficient). Hiervoor is een opnameprotocol opgesteld voor de woningbouw en de utiliteitsbouw, met als doel te controleren of en in hoeverre conform de EPC is gebouwd en om de gerealiseerde EPC te bepalen. Om ervaring op te doen met de nieuwe opnameprotocollen en de vrijwillige ventilatietoets werden het Opnameprotocol Energielabel Woningen Nieuwbouw (EWN) en Opnameprotocol Energielabel Utiliteitsgebouwen Nieuwbouw (EUN) uitgevoerd bij 12 nieuwbouwprojecten in de woningbouw en 5 projecten in de utiliteitsbouw. Met deze handleiding realiseert u energiezuinige woningen en/of utiliteitsgebouwen die aan de verwachtingen voldoen.

  7. A History of the Improvement of Internet Protocols Over Satellites Using ACTS

    Science.gov (United States)

    Allman, Mark; Kruse, Hans; Ostermann, Shawn

    2000-01-01

    This paper outlines the main results of a number of ACTS experiments on the efficacy of using standard Internet protocols over long-delay satellite channels. These experiments have been jointly conducted by NASAs Glenn Research Center and Ohio University over the last six years. The focus of our investigations has been the impact of long-delay networks with non-zero bit-error rates on the performance of the suite of Internet protocols. In particular, we have focused on the most widely used transport protocol, the Transmission Control Protocol (TCP), as well as several application layer protocols. This paper presents our main results, as well as references to more verbose discussions of our experiments.

  8. Use of a standardized JaCVAM in vivo rat comet assay protocol to assess the genotoxicity of three coded test compounds; ampicillin trihydrate, 1,2-dimethylhydrazine dihydrochloride, and N-nitrosodimethylamine.

    Science.gov (United States)

    McNamee, J P; Bellier, P V

    2015-07-01

    As part of the Japanese Center for the Validation of Alternative Methods (JaCVAM)-initiative international validation study of the in vivo rat alkaline comet assay (comet assay), our laboratory examined ampicillin trihydrate (AMP), 1,2-dimethylhydrazine dihydrochloride (DMH), and N-nitrosodimethylamine (NDA) using a standard comet assay validation protocol (v14.2) developed by the JaCVAM validation management team (VMT). Coded samples were received by our laboratory along with basic MSDS information. Solubility analysis and range-finding experiments of the coded test compounds were conducted for dose selection. Animal dosing schedules, the comet assay processing and analysis, and statistical analysis were conducted in accordance with the standard protocol. Based upon our blinded evaluation, AMP was not found to exhibit evidence of genotoxicity in either the rat liver or stomach. However, both NDA and DMH were observed to cause a significant increase in % tail DNA in the rat liver at all dose levels tested. While acute hepatoxicity was observed for these compounds in the high dose group, in the investigators opinion there were a sufficient number of consistently damaged/measurable cells at the medium and low dose groups to judge these compounds as genotoxic. There was no evidence of genotoxicity from either NDA or DMH in the rat stomach. In conclusion, our laboratory observed increased DNA damage from two blinded test compounds in rat liver (later identified as genotoxic carcinogens), while no evidence of genotoxicity was observed for the third blinded test compound (later identified as a non-genotoxic, non-carcinogen). This data supports the use of a standardized protocol of the in vivo comet assay as a cost-effective alternative genotoxicity assay for regulatory testing purposes. Crown Copyright © 2015. Published by Elsevier B.V. All rights reserved.

  9. DNA repair protocols

    DEFF Research Database (Denmark)

    Bjergbæk, Lotte

    In its 3rd edition, this Methods in Molecular Biology(TM) book covers the eukaryotic response to genomic insult including advanced protocols and standard techniques in the field of DNA repair. Offers expert guidance for DNA repair, recombination, and replication. Current knowledge of the mechanisms...... that regulate DNA repair has grown significantly over the past years with technology advances such as RNA interference, advanced proteomics and microscopy as well as high throughput screens. The third edition of DNA Repair Protocols covers various aspects of the eukaryotic response to genomic insult including...... recent advanced protocols as well as standard techniques used in the field of DNA repair. Both mammalian and non-mammalian model organisms are covered in the book, and many of the techniques can be applied with only minor modifications to other systems than the one described. Written in the highly...

  10. Critical Response Protocol

    Science.gov (United States)

    Ellingson, Charlene; Roehrig, Gillian; Bakkum, Kris; Dubinsky, Janet M.

    2016-01-01

    This article introduces the Critical Response Protocol (CRP), an arts-based technique that engages students in equitable critical discourse and aligns with the "Next Generation Science Standards" vision for providing students opportunities for language learning while advancing science learning (NGSS Lead States 2013). CRP helps teachers…

  11. Evaluating Application-Layer Traffic Optimization Cost Metrics for P2P Multimedia Streaming

    DEFF Research Database (Denmark)

    Poderys, Justas; Soler, José

    2017-01-01

    To help users of P2P communication systems perform better-than-random selection of communication peers, Internet Engineering Task Force standardized the Application Layer Traffic Optimization (ALTO) protocol. The ALTO provided data-routing cost metric, can be used to rank peers in P2P communicati...

  12. Compact Modbus TCP/IP protocol for data acquisition systems based on limited hardware resources

    Science.gov (United States)

    Bai, Q.; Jin, B.; Wang, D.; Wang, Y.; Liu, X.

    2018-04-01

    The Modbus TCP/IP has been a standard industry communication protocol and widely utilized for establishing sensor-cloud platforms on the Internet. However, numerous existing data acquisition systems built on traditional single-chip microcontrollers without sufficient resources cannot support it, because the complete Modbus TCP/IP protocol always works dependent on a full operating system which occupies abundant hardware resources. Hence, a compact Modbus TCP/IP protocol is proposed in this work to make it run efficiently and stably even on a resource-limited hardware platform. Firstly, the Modbus TCP/IP protocol stack is analyzed and the refined protocol suite is rebuilt by streamlining the typical TCP/IP suite. Then, specific implementation of every hierarchical layer is respectively presented in detail according to the protocol structure. Besides, the compact protocol is implemented in a traditional microprocessor to validate the feasibility of the scheme. Finally, the performance of the proposed scenario is assessed. The experimental results demonstrate that message packets match the frame format of Modbus TCP/IP protocol and the average bandwidth reaches to 1.15 Mbps. The compact protocol operates stably even based on a traditional microcontroller with only 4-kB RAM and 12-MHz system clock, and no communication congestion or frequent packet loss occurs.

  13. Relevant Standards

    Indian Academy of Sciences (India)

    .86: Ethernet over LAPS. Standard in China and India. G.7041: Generic Framing Procedure (GFP). Supports Ethernet as well as other data formats (e.g., Fibre Channel); Protocol of ... IEEE 802.3x for flow control of incoming Ethernet data ...

  14. Disinfectant wipes are appropriate to control microbial bioburden from surfaces: use of a new ASTM standard test protocol to demonstrate efficacy.

    Science.gov (United States)

    Sattar, S A; Bradley, C; Kibbee, R; Wesgate, R; Wilkinson, M A C; Sharpe, T; Maillard, J-Y

    2015-12-01

    The use of disinfectant pre-soaked wipes (DPW) to decontaminate high-touch environmental surfaces (HTES) by wiping is becoming increasingly widespread in the healthcare environment. However, DPW are rarely tested using conditions simulating their field use, and the label claims of environmental surface disinfectants seldom include wiping action. To evaluate the new E2967-15 standard test specific to wipes, particularly their ability to decontaminate surfaces and to transfer acquired contamination to clean surfaces. ASTM Standard E2967-15 was used by three independent laboratories to test the efficacy of five types of commercially available wipe products. All data generated were pulled together, and reproducibility and repeatability of the standard were measured. All the commercial DPW tested achieved a >4log10 (>99.99%) reduction in colony-forming units (CFU) of Staphylococcus aureus and Acinetobacter baumanii with 10s of wiping, but only one DPW containing 0.5% accelerated H2O2 prevented the transfer of bacteria to another surface. This newly introduced standard method represents a significant advance in assessing DPW for microbial decontamination of HTES, and should greatly assist research and development, and in making more relevant and reliable claims on marketed DPW. Copyright © 2015. Published by Elsevier Ltd.

  15. Non - Vegetated Standard Bioretention Structure Hydrodynamic Soil Characterization For Ponding - Layer Optimum Thickness Determination With A Distinctive Urban - Region Rainfall Event In Bogota

    Science.gov (United States)

    Velasco Ávila, Frank; Acero Rivero, Germán Eduardo; Angulo Jaramillo, Rafael

    2017-04-01

    Aiming to propose a system, in accordance with Best Management Practices (BMP) kind of structures, specifically a standard bioretention system in Bogota city, and in order to apply the inverse solution methodology on Hydrus - 1D, it is mandatory to determine each θ_s; θ_r; α;n and ks parameters in van Genuchten - Mualem function, without considering the hysteresis phenomenon, for a standard bioretention system composing soils, as well as required components and dimensions to implement the bioretention structure in Bogota. First, a bioretention structure general dimensioning was carried out based on current urban landscaping regulations and recommendations given by the sewage - system service provider in Bogota city. Soil composing and design were performed after information gathering and previous investigation on bioretention systems dimensioning from different sources such as manuals. To give an adequate interpretation of the vadose zone, a soil column experimental prototype was built to be able to control and measure the intervening parameters in the subsoil unidimensional flow description, such as capillary pressure, soil water saturation, inflow and outflow. Thirteen sensor - based devices were built to measure the inverse model required parameters. It is important to underline that all the designed instrumentation was based on low cost electronic development. In addition, the whole instrumentation system is controlled by an Arduino Mega PLC and was designed and built as a personal initiative by the author of this work. For signal processing and data capturing, a commercial Lab View version intuitive program was designed, to be able to create a user-friendly interface to make real-time sensor visualisation and control. Finally, all the hydrodynamic characterisation for the studied soils was made through a Hydrus-1D inverse model and laboratory experimenting and obtained results. In addition, several direct models were run in order to determinate both

  16. Effective therapy to reduce edema after total knee arthroplasty Multi-layer compression therapy or standard therapy with cool pack - a randomized controlled pilot trial

    Science.gov (United States)

    Stocker, Brigitta; Babendererde, Christine; Rohner-Spengler, Manuela; Müller, Urs W; Meichtry, André; Luomajoki, Hannu

    2018-02-01

    Background: After total knee arthroplasty (TKA) efficient control and reduction of postoperative edema is of great importance. Aim: The aim of this pilot study (EKNZ 2014 – 225 DRKS00006271) was to investigate the effectiveness of multi-layer compression therapy (MLCT) to reduce edema in the early period after surgery compared to the standard treatment with Cool Pack. Methods: In this randomized controlled pilot trial, sixteen patients after TKA were randomized into an intervention group (IG) or a control group (CG). Circumferential measurements were used to assess edema. Secondary outcomes were range of motion (ROM), pain (numeric rating scale, NRS) and function as measured with the fast Self Paced Walking Test (fSPWT). Results: Clinically relevant differences in edema reduction between the two groups were found in the early postoperative period and at the six weeks follow up. Six days postoperatively the group time interaction (IE) in favor of the IG were −3.8 cm (95 % CI: −5.1; −2.4) when measured 10 cm proximal to the joint space and −2.7 cm (CI: −4.1; −1.3) when measured 5 cm proximally. We further observed differences in secondary outcomes in favor of the CG. Six days postoperatively the IE for knee flexion was –8.3 ° (CI: −22.0; 5.4) and for the fSPWT it was 12.8 seconds (CI: −16.4; 41.3). Six weeks postoperatively these differences diminished. Conclusions: The findings suggest that MLCT could be an alternative treatment to reduce postoperative edema in patients after total knee arthroplasty. Eventually possible negative effects on early knee flexion and function must be considered.

  17. Silanization of silica and glass slides for DNA microarrays by impregnation and gas phase protocols: A comparative study

    International Nuclear Information System (INIS)

    Phaner-Goutorbe, Magali; Dugas, Vincent; Chevolot, Yann; Souteyrand, Eliane

    2011-01-01

    Surface immobilization of oligonucleotide probes (oligoprobes) is a key issue in the development of DNA-chips. The immobilization protocol should guarantee good availability of the probes, low non-specific adsorption and reproducibility. We have previously reported a silanization protocol with tert-butyl-11-(dimethylamino)silylundecanoate performed by impregnation (Impregnation Protocol, IP) of silica substrates from dilute silane solutions, leading to surfaces bearing carboxylic groups. In this paper, the Impregnation protocol is compared with a Gas phase Protocol (GP) which is more suited to industrial requirements such as reliable and robust processing, cost efficiency, etc.... The morphology of the oligoprobe films at the nanoscale (characterized by Atomic Force Microscopy) and the reproducibility of subsequent oligoprobes immobilization steps have been investigated for the two protocols on thermal silica (Si/SiO 2 ) and glass slide substrates. IP leads to smooth surfaces whereas GP induces the formation of islands features suggesting a non-continuous silane layer. The reproducibility of the overall surface layer (18.75 mm 2 ) has been evaluated through the covalent immobilization of a fluorescent oligoprobes. Average fluorescent signals of 6 (a.u.) and 4 (a.u.) were observed for IP and GP, respectively, with a standard deviation of 1 for both protocols. Thus, despite a morphological difference of the silane layer at the nanometer scale, the density of the immobilized probes remained similar.

  18. Decontamination systems information and research program -- Literature review in support of development of standard test protocols and barrier design models for in situ formed barriers project

    International Nuclear Information System (INIS)

    1994-12-01

    The US Department of Energy is responsible for approximately 3,000 sites in which contaminants such as carbon tetrachloride, trichlorethylene, perchlorethylene, non-volatile and soluble organic and insoluble organics (PCBs and pesticides) are encountered. In specific areas of these sites radioactive contaminants are stored in underground storage tanks which were originally designed and constructed with a 30-year projected life. Many of these tanks are now 10 years beyond the design life and failures have occurred allowing the basic liquids (ph of 8 to 9) to leak into the unconsolidated soils below. Nearly one half of the storage tanks located at the Hanford Washington Reservation are suspected of leaking and contaminating the soils beneath them. The Hanford site is located in a semi-arid climate region with rainfall of less than 6 inches annually, and studies have indicated that very little of this water finds its way to the groundwater to move the water down gradient toward the Columbia River. This provides the government with time to develop a barrier system to prevent further contamination of the groundwater, and to develop and test remediation systems to stabilize or remove the contaminant materials. In parallel to remediation efforts, confinement and containment technologies are needed to retard or prevent the advancement of contamination plumes through the environment until the implementation of remediation technology efforts are completed. This project examines the various confinement and containment technologies and protocols for testing the materials in relation to their function in-situ

  19. A new improved protocol for in vitro intratubular dentinal bacterial contamination for antimicrobial endodontic tests: standardization and validation by confocal laser scanning microscopy

    Directory of Open Access Journals (Sweden)

    Flaviana Bombarda de ANDRADE

    2015-01-01

    Full Text Available Objectives To compare three methods of intratubular contamination that simulate endodontic infections using confocal laser scanning microscopy (CLSM. Material and Methods Two pre-existing models of dentinal contamination were used to induce intratubular infection (groups A and B. These methods were modified in an attempt to improve the model (group C. Among the modifications it may be included: specimen contamination for five days, ultrasonic bath with BHI broth after specimen sterilization, use of E. faecalis during the exponential growth phase, greater concentration of inoculum, and two cycles of centrifugation on alternate days with changes of culture media. All specimens were longitudinally sectioned and stained with of LIVE/DEAD® for 20 min. Specimens were assessed using CLSM, which provided images of the depth of viable bacterial proliferation inside the dentinal tubules. Additionally, three examiners used scores to classify the CLSM images according to the following parameters: homogeneity, density, and depth of the bacterial contamination inside the dentinal tubules. Kruskal-Wallis and Dunn’s tests were used to evaluate the live and dead cells rates, and the scores obtained. Results The contamination scores revealed higher contamination levels in group C when compared with groups A and B (p0.05. The volume of live cells in group C was higher than in groups A and B (p<0.05. Conclusion The new protocol for intratubular infection resulted in high and uniform patterns of bacterial contamination and higher cell viability in all specimens when compared with the current methods.

  20. Enhanced Application of 18F-FDG PET/CT in Bladder Cancer by Adding Early Dynamic Acquisition to a Standard Delayed PET Protocol.

    Science.gov (United States)

    Yoon, Hai-Jeon; Yoo, Jang; Kim, Yemi; Lee, Dong Hyeon; Kim, Bom Sahn

    2017-10-01

    We investigated the value of early dynamic (ED) PET for the detection and characterization of bladder cancer. Fifty-two bladder cancer patients were prospectively enrolled. The study protocol was composed of ED, whole-body (WB, 60 minutes after injection), and additional delayed (AD, 120 minutes after injection) PET acquisition. Early dynamic PET was acquired for 10 minutes and reconstructed as 5 frames at 2-minute intervals. A focal radiotracer accumulation confined to the bladder wall was considered as PET positive and referred for further quantitative measurement. SUVmax on ED (SUVmax, SUVmax, SUVmax, SUVmax, and SUVmax for 5 frames), WB (SUVmax), and AD PET (SUVmax) were measured. PET results were correlated with bladder cancer pathology variables. The sensitivities of ED, WB, and AD PET for bladder cancer were 84.6%, 57.7%, and 61.2%, respectively. The sensitivity of ED PET was significantly higher than that of WB (P = 0.002) and AD PET (P = 0.008). On ED PET, SUVmax was significantly correlated with muscle invasiveness, histological grade, and pathological tumor size (P = 0.018, P = 0.030, and P = 0.030). On WB and AD PET, only pathological tumor size showed significant positive correlation with SUVmax and SUVmax (P = 0.043 and P = 0.007). Early dynamic PET can help to detect and characterize bladder cancer.

  1. Research and implementation of intelligent gateway driver layer based on Linux bus

    Directory of Open Access Journals (Sweden)

    ZHANG Jian

    2016-10-01

    Full Text Available Currently,in the field of smart home,there is no relevant organization that yet has proposed an unified protocol standard.It increases the complexity and limitations of heterogeneous gateway software framework design that different vendor′s devices have different communication mode and protocol standards.In this paper,a serial of interfaces are provided by Linux kernel,and a virtual bus is registered under Linux.The physical device drivers are able to connect to the virtual bus.The detailed designs of the communication protocol are placed in the underlying adapters,making the integration of heterogeneous networks more natural.At the same time,designing the intelligent gateway system driver layer based on Linux bus can let the application layer be more unified and clear logical.And it also let the hardware access network become more convenient and distinct.

  2. A Secure Key Establishment Protocol for ZigBee Wireless Sensor Networks

    DEFF Research Database (Denmark)

    Yuksel, Ender; Nielson, Hanne Riis; Nielson, Flemming

    2009-01-01

    ZigBee is a wireless sensor network standard that defines network and application layers on top of IEEE 802.15.4’s physical and medium access control layers. In the latest version of ZigBee, enhancements are prescribed for the security sublayer but we show in this paper that problems persist....... In particular we show that the End-to-End Application Key Establishment Protocol is flawed and we propose a secure protocol instead. We do so by using formal verification techniques based on static program analysis and process algebras. We present a way of using formal methods in wireless network security......, and propose a secure key establishment protocol for ZigBee networks....

  3. Cryptographic Protocols:

    DEFF Research Database (Denmark)

    Geisler, Martin Joakim Bittel

    cryptography was thus concerned with message confidentiality and integrity. Modern cryptography cover a much wider range of subjects including the area of secure multiparty computation, which will be the main topic of this dissertation. Our first contribution is a new protocol for secure comparison, presented...... implemented the comparison protocol in Java and benchmarks show that is it highly competitive and practical. The biggest contribution of this dissertation is a general framework for secure multiparty computation. Instead of making new ad hoc implementations for each protocol, we want a single and extensible...... in Chapter 2. Comparisons play a key role in many systems such as online auctions and benchmarks — it is not unreasonable to say that when parties come together for a multiparty computation, it is because they want to make decisions that depend on private information. Decisions depend on comparisons. We have...

  4. Development of high-reliable real-time communication network protocol for SMART

    Energy Technology Data Exchange (ETDEWEB)

    Song, Ki Sang; Kim, Young Sik [Korea National University of Education, Chongwon (Korea); No, Hee Chon [Korea Advanced Institute of Science and Technology, Taejon (Korea)

    1999-04-01

    In this research, we first define protocol subsets for SMART(System-integrated Modular Advanced Reactor) communication network based on the requirement of SMART MMIS transmission delay and traffic requirements and OSI(Open System Interconnection) 7 layers' network protocol functions. Also, current industrial purpose LAN protocols are analyzed and the applicability of commercialized protocols are checked. For the suitability test, we have applied approximated SMART data traffic and maximum allowable transmission delay requirement. With the simulation results, we conclude that IEEE 802.5 and FDDI which is an ANSI standard, is the most suitable for SMART. We further analyzed the FDDI and token ring protocols for SMART and nuclear plant network environment including IEEE 802.4, IEEE 802.5, and ARCnet. The most suitable protocol for SMART is FDDI and FDDI MAC and RMT protocol specifications have been verified with LOTOS and the verification results show that FDDI MAC and RMT satisfy the reachability and liveness, but does not show deadlock and livelock. Therefore, we conclude that FDDI MAC and RMT is highly reliable protocol for SMART MMIS network. After that, we consider the stacking fault of IEEE 802.5 token ring protocol and propose a fault tolerant MAM(Modified Active Monitor) protocol. The simulation results show that the MAM protocol improves lower priority traffic service rate when stacking fault occurs. Therefore, proposed MAM protocol can be applied to SMART communication network for high reliability and hard real-time communication purpose in data acquisition and inter channel network. (author). 37 refs., 79 figs., 39 tabs.

  5. Computed tomography of the cervical spine: comparison of image quality between a standard-dose and a low-dose protocol using filtered back-projection and iterative reconstruction

    Energy Technology Data Exchange (ETDEWEB)

    Becce, Fabio [University of Lausanne, Department of Diagnostic and Interventional Radiology, Centre Hospitalier Universitaire Vaudois, Lausanne (Switzerland); Universite Catholique Louvain, Department of Radiology, Cliniques Universitaires Saint-Luc, Brussels (Belgium); Ben Salah, Yosr; Berg, Bruno C. vande; Lecouvet, Frederic E.; Omoumi, Patrick [Universite Catholique Louvain, Department of Radiology, Cliniques Universitaires Saint-Luc, Brussels (Belgium); Verdun, Francis R. [University of Lausanne, Institute of Radiation Physics, Centre Hospitalier Universitaire Vaudois, Lausanne (Switzerland); Meuli, Reto [University of Lausanne, Department of Diagnostic and Interventional Radiology, Centre Hospitalier Universitaire Vaudois, Lausanne (Switzerland)

    2013-07-15

    To compare image quality of a standard-dose (SD) and a low-dose (LD) cervical spine CT protocol using filtered back-projection (FBP) and iterative reconstruction (IR). Forty patients investigated by cervical spine CT were prospectively randomised into two groups: SD (120 kVp, 275 mAs) and LD (120 kVp, 150 mAs), both applying automatic tube current modulation. Data were reconstructed using both FBP and sinogram-affirmed IR. Image noise, signal-to-noise (SNR) and contrast-to-noise (CNR) ratios were measured. Two radiologists independently and blindly assessed the following anatomical structures at C3-C4 and C6-C7 levels, using a four-point scale: intervertebral disc, content of neural foramina and dural sac, ligaments, soft tissues and vertebrae. They subsequently rated overall image quality using a ten-point scale. For both protocols and at each disc level, IR significantly decreased image noise and increased SNR and CNR, compared with FBP. SNR and CNR were statistically equivalent in LD-IR and SD-FBP protocols. Regardless of the dose and disc level, the qualitative scores with IR compared with FBP, and with LD-IR compared with SD-FBP, were significantly higher or not statistically different for intervertebral discs, neural foramina and ligaments, while significantly lower or not statistically different for soft tissues and vertebrae. The overall image quality scores were significantly higher with IR compared with FBP, and with LD-IR compared with SD-FBP. LD-IR cervical spine CT provides better image quality for intervertebral discs, neural foramina and ligaments, and worse image quality for soft tissues and vertebrae, compared with SD-FBP, while reducing radiation dose by approximately 40 %. (orig.)

  6. Computed tomography of the cervical spine: comparison of image quality between a standard-dose and a low-dose protocol using filtered back-projection and iterative reconstruction

    International Nuclear Information System (INIS)

    Becce, Fabio; Ben Salah, Yosr; Berg, Bruno C. vande; Lecouvet, Frederic E.; Omoumi, Patrick; Verdun, Francis R.; Meuli, Reto

    2013-01-01

    To compare image quality of a standard-dose (SD) and a low-dose (LD) cervical spine CT protocol using filtered back-projection (FBP) and iterative reconstruction (IR). Forty patients investigated by cervical spine CT were prospectively randomised into two groups: SD (120 kVp, 275 mAs) and LD (120 kVp, 150 mAs), both applying automatic tube current modulation. Data were reconstructed using both FBP and sinogram-affirmed IR. Image noise, signal-to-noise (SNR) and contrast-to-noise (CNR) ratios were measured. Two radiologists independently and blindly assessed the following anatomical structures at C3-C4 and C6-C7 levels, using a four-point scale: intervertebral disc, content of neural foramina and dural sac, ligaments, soft tissues and vertebrae. They subsequently rated overall image quality using a ten-point scale. For both protocols and at each disc level, IR significantly decreased image noise and increased SNR and CNR, compared with FBP. SNR and CNR were statistically equivalent in LD-IR and SD-FBP protocols. Regardless of the dose and disc level, the qualitative scores with IR compared with FBP, and with LD-IR compared with SD-FBP, were significantly higher or not statistically different for intervertebral discs, neural foramina and ligaments, while significantly lower or not statistically different for soft tissues and vertebrae. The overall image quality scores were significantly higher with IR compared with FBP, and with LD-IR compared with SD-FBP. LD-IR cervical spine CT provides better image quality for intervertebral discs, neural foramina and ligaments, and worse image quality for soft tissues and vertebrae, compared with SD-FBP, while reducing radiation dose by approximately 40 %. (orig.)

  7. Considerations for the design and execution of protocols for animal research and treatment to improve reproducibility and standardization: "DEPART well-prepared and ARRIVE safely".

    Science.gov (United States)

    Smith, M M; Clarke, E C; Little, C B

    2017-03-01

    To review the factors in experimental design that contribute to poor translation of pre-clinical research to therapies for patients with osteoarthritis (OA) and how this might be improved. Narrative review of the literature, and evaluation of the different stages of design conduct and analysis of studies using animal models of OA to define specific issues that might reduce quality of evidence and how this can be minimised. Preventing bias and improving experimental rigour and reporting are important modifiable factors to improve translation from pre-clinical animal models to successful clinical trials of therapeutic agents. Despite publication and adoption by many journals of guidelines such as Animals in Research: Reporting In Vivo Experiments (ARRIVE), experimental animal studies published in leading rheumatology journals are still deficient in their reporting. In part, this may be caused by researchers first consulting these guidelines after the completion of experiments, at the time of publication. This review discusses factors that can (1) bias the outcome of experimental studies using animal models of osteoarthritis or (2) alter the quality of evidence for translation. We propose a checklist to consult prior to starting experiments; in the Design and Execution of Protocols for Animal Research and Treatment (DEPART). Following DEPART during the design phase will enable completion of the ARRIVE checklist at the time of publication, and thus improve the quality of evidence for inclusion of experimental animal research in meta-analyses and systematic reviews: "DEPART well-prepared and ARRIVE safely". Copyright © 2016 Osteoarthritis Research Society International. Published by Elsevier Ltd. All rights reserved.

  8. The AQUA-FONTIS study: protocol of a multidisciplinary, cross-sectional and prospective longitudinal study for developing standardized diagnostics and classification of non-thyroidal illness syndrome

    Science.gov (United States)

    Dietrich, Johannes W; Stachon, Axel; Antic, Biljana; Klein, Harald H; Hering, Steffen

    2008-01-01

    Background Non-thyroidal illness syndrome (NTIS) is a characteristic functional constellation of thyrotropic feedback control that frequently occurs in critically ill patients. Although this condition is associated with significantly increased morbidity and mortality, there is still controversy on whether NTIS is caused by artefacts, is a form of beneficial adaptation, or is a disorder requiring treatment. Trials investigating substitution therapy of NTIS revealed contradictory results. The comparison of heterogeneous patient cohorts may be the cause for those inconsistencies. Objectives Primary objective of this study is the identification and differentiation of different functional states of thyrotropic feedback control in order to define relevant evaluation criteria for the prognosis of affected patients. Furthermore, we intend to assess the significance of an innovative physiological index approach (SPINA) in differential diagnosis between NTIS and latent (so-called "sub-clinical") thyrotoxicosis. Secondary objective is observation of variables that quantify distinct components of NTIS in the context of independent predictors of evolution, survival or pathophysiological condition and influencing or disturbing factors like medication. Design The approach to a quantitative follow-up of non-thyroidal illness syndrome (AQUA FONTIS study) is designed as both a cross-sectional and prospective longitudinal observation trial in critically ill patients. Patients are observed in at least two evaluation points with consecutive assessments of thyroid status, physiological and clinical data in additional weekly observations up to discharge. A second part of the study investigates the neuropsychological impact of NTIS and medium-term outcomes. The study design incorporates a two-module structure that covers a reduced protocol in form of an observation trial before patients give informed consent. Additional investigations are performed if and after patients agree in

  9. The AQUA-FONTIS study: protocol of a multidisciplinary, cross-sectional and prospective longitudinal study for developing standardized diagnostics and classification of non-thyroidal illness syndrome

    Directory of Open Access Journals (Sweden)

    Klein Harald H

    2008-10-01

    Full Text Available Abstract Background Non-thyroidal illness syndrome (NTIS is a characteristic functional constellation of thyrotropic feedback control that frequently occurs in critically ill patients. Although this condition is associated with significantly increased morbidity and mortality, there is still controversy on whether NTIS is caused by artefacts, is a form of beneficial adaptation, or is a disorder requiring treatment. Trials investigating substitution therapy of NTIS revealed contradictory results. The comparison of heterogeneous patient cohorts may be the cause for those inconsistencies. Objectives Primary objective of this study is the identification and differentiation of different functional states of thyrotropic feedback control in order to define relevant evaluation criteria for the prognosis of affected patients. Furthermore, we intend to assess the significance of an innovative physiological index approach (SPINA in differential diagnosis between NTIS and latent (so-called "sub-clinical" thyrotoxicosis. Secondary objective is observation of variables that quantify distinct components of NTIS in the context of independent predictors of evolution, survival or pathophysiological condition and influencing or disturbing factors like medication. Design The approach to a quantitative follow-up of non-thyroidal illness syndrome (AQUA FONTIS study is designed as both a cross-sectional and prospective longitudinal observation trial in critically ill patients. Patients are observed in at least two evaluation points with consecutive assessments of thyroid status, physiological and clinical data in additional weekly observations up to discharge. A second part of the study investigates the neuropsychological impact of NTIS and medium-term outcomes. The study design incorporates a two-module structure that covers a reduced protocol in form of an observation trial before patients give informed consent. Additional investigations are performed if and after

  10. In silico toxicology protocols.

    Science.gov (United States)

    Myatt, Glenn J; Ahlberg, Ernst; Akahori, Yumi; Allen, David; Amberg, Alexander; Anger, Lennart T; Aptula, Aynur; Auerbach, Scott; Beilke, Lisa; Bellion, Phillip; Benigni, Romualdo; Bercu, Joel; Booth, Ewan D; Bower, Dave; Brigo, Alessandro; Burden, Natalie; Cammerer, Zoryana; Cronin, Mark T D; Cross, Kevin P; Custer, Laura; Dettwiler, Magdalena; Dobo, Krista; Ford, Kevin A; Fortin, Marie C; Gad-McDonald, Samantha E; Gellatly, Nichola; Gervais, Véronique; Glover, Kyle P; Glowienke, Susanne; Van Gompel, Jacky; Gutsell, Steve; Hardy, Barry; Harvey, James S; Hillegass, Jedd; Honma, Masamitsu; Hsieh, Jui-Hua; Hsu, Chia-Wen; Hughes, Kathy; Johnson, Candice; Jolly, Robert; Jones, David; Kemper, Ray; Kenyon, Michelle O; Kim, Marlene T; Kruhlak, Naomi L; Kulkarni, Sunil A; Kümmerer, Klaus; Leavitt, Penny; Majer, Bernhard; Masten, Scott; Miller, Scott; Moser, Janet; Mumtaz, Moiz; Muster, Wolfgang; Neilson, Louise; Oprea, Tudor I; Patlewicz, Grace; Paulino, Alexandre; Lo Piparo, Elena; Powley, Mark; Quigley, Donald P; Reddy, M Vijayaraj; Richarz, Andrea-Nicole; Ruiz, Patricia; Schilter, Benoit; Serafimova, Rositsa; Simpson, Wendy; Stavitskaya, Lidiya; Stidl, Reinhard; Suarez-Rodriguez, Diana; Szabo, David T; Teasdale, Andrew; Trejo-Martin, Alejandra; Valentin, Jean-Pierre; Vuorinen, Anna; Wall, Brian A; Watts, Pete; White, Angela T; Wichard, Joerg; Witt, Kristine L; Woolley, Adam; Woolley, David; Zwickl, Craig; Hasselgren, Catrin

    2018-04-17

    The present publication surveys several applications of in silico (i.e., computational) toxicology approaches across different industries and institutions. It highlights the need to develop standardized protocols when conducting toxicity-related predictions. This contribution articulates the information needed for protocols to support in silico predictions for major toxicological endpoints of concern (e.g., genetic toxicity, carcinogenicity, acute toxicity, reproductive toxicity, developmental toxicity) across several industries and regulatory bodies. Such novel in silico toxicology (IST) protocols, when fully developed and implemented, will ensure in silico toxicological assessments are performed and evaluated in a consistent, reproducible, and well-documented manner across industries and regulatory bodies to support wider uptake and acceptance of the approaches. The development of IST protocols is an initiative developed through a collaboration among an international consortium to reflect the state-of-the-art in in silico toxicology for hazard identification and characterization. A general outline for describing the development of such protocols is included and it is based on in silico predictions and/or available experimental data for a defined series of relevant toxicological effects or mechanisms. The publication presents a novel approach for determining the reliability of in silico predictions alongside experimental data. In addition, we discuss how to determine the level of confidence in the assessment based on the relevance and reliability of the information. Copyright © 2018. Published by Elsevier Inc.

  11. Outcome after polytrauma in a certified trauma network: comparing standard vs. maximum care facilities concept of the study and study protocol (POLYQUALY).

    Science.gov (United States)

    Koller, Michael; Ernstberger, Antonio; Zeman, Florian; Loss, Julika; Nerlich, Michael

    2016-07-11

    The aim of this study is to evaluate the performance of the first certified regional trauma network in Germany, the Trauma Network Eastern Bavaria (TNO) addressing the following specific research questions: Do standard and maximum care facilities produce comparable (risk-adjusted) levels of patient outcome? Does TNO outperform reference data provided by the German Trauma Register 2008? Does TNO comply with selected benchmarks derived from the S3 practice guideline? Which barriers and facilitators can be identified in the health care delivery processes for polytrauma patients? The design is based on a prospective multicenter cohort study comparing two cohorts of polytrauma patients: those treated in maximum care facilities and those treated in standard care facilities. Patient recruitment will take place in the 25 TNO clinics. It is estimated that n = 1.100 patients will be assessed for eligibility within a two-year period and n = 800 will be included into the study and analysed. Main outcome measures include the TraumaRegisterQM form, which has been implemented in the clinical routine since 2009 and is filled in via a web-based data management system in participating hospitals on a mandatory basis. Furthermore, patient-reported outcome is assessed using the EQ-5D at 6, 12 and 24 months after trauma. Comparisons will be drawn between the two cohorts. Further standards of comparisons are secondary data derived from German Trauma Registry as well as benchmarks from German S3 guideline on polytrauma. The qualitative part of the study will be based on semi-standardized interviews and focus group discussions with health care providers within TNO. The goal of the qualitative analysis is to elucidate which facilitating and inhibiting forces influence cooperation and performance within the network. This is the first study to evaluate a certified trauma network within the German health care system using a unique combination of a quantitative (prospective cohort

  12. Phase Transition in Protocols Minimizing Work Fluctuations

    Science.gov (United States)

    Solon, Alexandre P.; Horowitz, Jordan M.

    2018-05-01

    For two canonical examples of driven mesoscopic systems—a harmonically trapped Brownian particle and a quantum dot—we numerically determine the finite-time protocols that optimize the compromise between the standard deviation and the mean of the dissipated work. In the case of the oscillator, we observe a collection of protocols that smoothly trade off between average work and its fluctuations. However, for the quantum dot, we find that as we shift the weight of our optimization objective from average work to work standard deviation, there is an analog of a first-order phase transition in protocol space: two distinct protocols exchange global optimality with mixed protocols akin to phase coexistence. As a result, the two types of protocols possess qualitatively different properties and remain distinct even in the infinite duration limit: optimal-work-fluctuation protocols never coalesce with the minimal-work protocols, which therefore never become quasistatic.

  13. A New Method for Treatment of Lymphedema of Limbs: Standardized Manual Massage with a New Device Linforoll in Conservative and Surgical Therapy Protocols.

    Science.gov (United States)

    Olszewski, Waldemar L; Zaleska, Marzanna; Michelin, Sandro

    2016-12-01

    Edema fluid in lymphedematous limbs should be evacuated to sites where it can be absorbed. It should be moved either to the hypogastrium or arm/scapular regions along tissue channels or implanted silicon channels or through lymphovenous anastomoses. For that purpose, the manual lymphatic drainage of limb is an effective method. Standardization of manual massage applied force and timing becomes necessary. A device with known pressing area and continuously showing the applied force while moving it toward the root of the limb is needed. Moreover, force could be adjusted to the stiffness of the massaged tissues that varies at different levels of the limb. Results from such a device would be repeatable and reproducible by others. In this study we present data on tissue fluid hydromechanics obtained from 20 patients with obstructive limb lymphedema during massage with a massaging roller called Linforoll. Linforoll is composed of a hand piece with roller and pressure sensor connected wireless to the computer displaying the pressure curve of the applied force. Electron microscopy studies for checking eventual tissue changes were done. Linforoll provides the possibilities of: 1) regulating the applied force according to the hydromechanic conditions of the massaged tissues; 2) standardization of massage repeatable in the same patient; 3) decrease of limb volume; 4) evident increase in tissue elasticity; 5) application as a driving force for fluid flow along the surgically implanted tubing and vessels running to the lymphovenous shunts.

  14. Immunochemical protocols

    National Research Council Canada - National Science Library

    Pound, John D

    1998-01-01

    ... easy and important refinements often are not published. This much anticipated 2nd edition of Immunochemzcal Protocols therefore aims to provide a user-friendly up-to-date handbook of reliable techniques selected to suit the needs of molecular biologists. It covers the full breadth of the relevant established immunochemical methods, from protein blotting and immunoa...

  15. Report on the behalf of the Foreign Affairs Commission on the bill project authorizing the approval of the amendment to the Montreal protocol of 16 September 1987 related to substances which impoverish the ozone layer, and its Annexe: text of the foreign affairs Commission. Nr 415

    International Nuclear Information System (INIS)

    Di Pompeo, Christophe

    2017-01-01

    The objective of the Montreal protocol, adopted in 1987, was to banish the chlorofluorocarbons (CFC) used as refrigerants since the 1930's, as they are responsible for the impoverishment of the ozone layer. While this objective has been met (the ozone layer is progressively restored), substitutes to CFC have been developed; however some of these substitutes, hydro-fluorocarbons, have been proved to be powerful greenhouse gases. The banishment of HFCs has thus been decided, leading to the Kigali amendment to the Montreal protocol. This report explains the CFC and HFC context and issues in details, and presents its examination by the French Commission of Foreign Affairs. The full text of the report is included (in an annex) at the end of the report

  16. A standardized crisis management model for self-harming and suicidal individuals with three or more diagnostic criteria of borderline personality disorder: The Brief Admission Skåne randomized controlled trial protocol (BASRCT).

    Science.gov (United States)

    Liljedahl, Sophie I; Helleman, Marjolein; Daukantaité, Daiva; Westrin, Åsa; Westling, Sofie

    2017-06-15

    Brief Admission is a crisis and risk management strategy in which self-harming and suicidal individuals with three or more diagnostic criteria of borderline personality disorder self-admit to hospital at times of increasing risk when other efforts to stay safe are failing. Standardized in the current randomized controlled trial, the intensity of Brief Admission Skåne is implemented in durations of three days, with a maximum frequency of three times a month. Brief Admission is integrated into existing treatment plans in advance of crises to prevent reliance on general psychiatric admissions for risk management, as these may be lengthy, unstructured, and of uncertain therapeutic value. The overall objective of the Brief Admission Skåne randomized controlled trial is to determine if Brief Admission can replace general psychiatric admission for self-harming and suicidal individuals with complex mental illness at times of escalating risk. Other objectives of the study are to evaluate whether Brief Admission increases daily functioning and enhances coping, reduces psychiatric symptoms including frequency and severity of self-harm and suicidal behaviours. A final objective is to determine if Brief Admission is an effective crisis management model for this population. Participants are randomized at an individual level to either Brief Admission Skåne plus Treatment as Usual or Treatment As Usual. Based on a priori power analyses, N = 124 participants will be recruited to the study. Data collection is in progress, and will continue until June 2018. All participant data are single-blinded and will be handled with intention-to-treat analysis. Based on the combined clinical experience of our international research group, the Brief Admission Skåne randomized controlled trial upon which the current protocol is based represents the first initiative to standardize, implement and evaluate Brief Admission amongst self-harming and suicidal individuals, including those with

  17. Study, design and realization of a fault-tolerant and predictable synchronous communication protocol on off-the-shelf components; Etude, conception et mise en oeuvre d'un protocole de communication synchrone tolerant aux fautes et predictible sur des composants reseaux standards

    Energy Technology Data Exchange (ETDEWEB)

    Chabrol, D

    2006-06-15

    This PhD thesis contributes to the design and realization of safety-critical real-time systems on multiprocessor architectures with distributed memory. They are essential to compute systems that have to ensure complex and critical functions. This PhD thesis deals with communication media management. The communication management conditions strongly the capability of the system to fulfill the timeliness property and the dependability requirements. Our contribution includes: - The design of predictable and fault-tolerant synchronous communication protocol; - The study and the definition of the execution model to have a efficient and safe communications management; - The proposal of a method to generate automatically the communications scheduling. Our approach is based on a communication model that allows the analysis of the feasibility, before execution, of a distributed safe-critical real-time system with timeliness and safety requirements. This leads to the definition of an execution model based on a time-triggered and parallel communication management. A set of linear constraints system is generated automatically to compute the network scheduling and the network load with timeliness fulfillment. Then, the proposed communication interface is based on an advanced version of TDMA protocol which allows to use proprietary components (TTP, FlexRay) as well as standard components (Ethernet). The concepts presented in this thesis lead to the realisation and evaluation of a prototype within the framework of the OASIS project done at the CEA/List. (author)

  18. Institutional protocol to standardize the chest drainage system management, from surgery to nursing care, at a regional hospital in northern Paraná

    Directory of Open Access Journals (Sweden)

    Amanda Carina Coelho de Morais

    2016-09-01

    Full Text Available The purpose of chest drainage is to allow lung re-expansion and the reestablishment of the subatmospheric pressure in the pleural space. Properly managing the drainage system minimizes procedure-related complications. This prospective observational study evaluated adult patients undergoing water-seal chest drainage, admitted to our hospital and accompanied by residents and tutors, aiming to check their care. One hundred chest drainages were monitored. The average age was 38.8 years old. The average drainage time was 6.7 days. Trauma was the prevalent cause (72% for the indication of pleural drainage. The obstruction of the system occurred in 6% of the cases; 5% subcutaneous emphysema, 1% infection around the drain; 5% accidental dislodgement of the drain, and in 5% of the patients, there were some complications when removing the drain. Failures in chest drainage technique and management were present, and reflected in some complications that are inherent to the procedure, although it is known that there are intrinsic complications. This study aimed to assess the management of closed chest drainage systems and standardize the care provided in such procedure.

  19. Diagnosis of cerebral metastases by means of standard doses of Gadobutrol versus a high-dose protocol. Intraindividual evaluation of a phase-II high-dose study

    International Nuclear Information System (INIS)

    Vogl, T.J.; Friebe, C.E.; Balzer, T.; Mack, M.G.; Steiner, S.; Schedel, H.; Pegios, W.; Lanksch, W.; Banzer, D.; Felix, R.

    1995-01-01

    In a clinical phase-II study 20 patients who had been diagnosed as having brain metastases with CT or MRT were studied prospectively with Gadobutrol, a new nonionic, low osmolality contrast agent. Each patient received an initial injection of 0.1 mmol/kg body weight and an additional dose of 0.2 mmol/kg Gadobutrol 10 min later. Spinecho images were obtained before and after the two applications of Gadobutrol. Dynamic scanning (Turbo-FLASH) was performed for 3 min after each injection of the contrast agent. Both quantitative and qualitative data were intraindividually evaluated. The primary tumor was a bronchial carcinoma in 11 cases; in 9 other cases there were different primary tumors. Forty-eight hours after the use of Gadobutrol there were no adverse signs in the clinical examination, vital signs or blood and urine chemistry. Statistical analysis (Friedman test and Wilcoxon test) of the C/N ratios between tumor and white matter, percentage enhancement, and visual assessment rating revealed statistically significant superiority of high-dose Gadobutrol injection in comparison to the standard dose. The percentage enhancement increased on average from 104% after 0.1 mmol/kg to 162% after 0.3 mmol/kg Gadobutrol. Qualitative delineation and contrast of the lesions increased significantly. The use of high-dose Gadobutrol improved the detection of 36 additional lesions in 6 patients. (orig./VHE) [de

  20. Analyzing the effect of routing protocols on media access control protocols in radio networks

    Energy Technology Data Exchange (ETDEWEB)

    Barrett, C. L. (Christopher L.); Drozda, M. (Martin); Marathe, A. (Achla); Marathe, M. V. (Madhav V.)

    2002-01-01

    We study the effect of routing protocols on the performance of media access control (MAC) protocols in wireless radio networks. Three well known MAC protocols: 802.11, CSMA, and MACA are considered. Similarly three recently proposed routing protocols: AODV, DSR and LAR scheme 1 are considered. The experimental analysis was carried out using GloMoSim: a tool for simulating wireless networks. The main focus of our experiments was to study how the routing protocols affect the performance of the MAC protocols when the underlying network and traffic parameters are varied. The performance of the protocols was measured w.r.t. five important parameters: (i) number of received packets, (ii) average latency of each packet, (iii) throughput (iv) long term fairness and (v) number of control packets at the MAC layer level. Our results show that combinations of routing and MAC protocols yield varying performance under varying network topology and traffic situations. The result has an important implication; no combination of routing protocol and MAC protocol is the best over all situations. Also, the performance analysis of protocols at a given level in the protocol stack needs to be studied not locally in isolation but as a part of the complete protocol stack. A novel aspect of our work is the use of statistical technique, ANOVA (Analysis of Variance) to characterize the effect of routing protocols on MAC protocols. This technique is of independent interest and can be utilized in several other simulation and empirical studies.

  1. An eHealth program versus a standard care supervised health program and associated health outcomes in individuals with mobility disability: study protocol for a randomized controlled trial.

    Science.gov (United States)

    Berglind, Daniel; Nyberg, Gisela; Willmer, Mikaela; Persson, Margareta; Wells, Michael; Forsell, Yvonne

    2018-04-27

    Young adults with mobility disability (MD) are less likely to engage in regular physical activity (PA) compared with their able-bodied peers and inactive adults with a MD are more likely to report one or more chronic diseases compared to those who are physically active. Despite the vast amount of research published in the field of PA interventions over the past decades, little attention has been focused on interventions aiming to increase PA among individuals with MD. Thus, we propose to compare the effects of an eHealth program compared to a usual care supervised health program on levels of PA and other health behaviors. The current intervention will use a randomized controlled trial (RCT) design with two treatment groups (an eHealth program and a usual care supervised health program) in young adults with newly acquired MD. In total, 110 young adults (aged 18-40 years) with a MD, acquired within the past 3 years, will be recruited to participate in a 12-week intervention. The primary study outcome is accelerometer-measured time spent in moderate to vigorous PA. Secondary outcomes includes health-related quality of life, depression, stress, fitness, body composition, diet, musculoskeletal pain, motivation to exercise and work ability. There is a lack of RCTs investigating effective ways to increase levels of PA in young adults with MD. Increased levels of PA among this physically inactive population have the potential to substantially improve health-related outcomes, possibly more so than in the general population. The trial will put strong emphasis on optimizing exercise adherence and investigating feasibility in the two treatment programs. The Ethical Review Board (EPN) at Karolinska Institutet has approved the study (2017/1206-31/1). International Standard Randomised Controlled Trial Number (ISRCTN), reference number ISRCTN22387524 . Prospectively registered February 4, 2018.

  2. Extra Physiotherapy in Critical Care (EPICC) Trial Protocol: a randomised controlled trial of intensive versus standard physical rehabilitation therapy in the critically ill.

    Science.gov (United States)

    Thomas, Kirsty; Wright, Stephen E; Watson, Gillian; Baker, Catherine; Stafford, Victoria; Wade, Clare; Chadwick, Thomas J; Mansfield, Leigh; Wilkinson, Jennifer; Shen, Jing; Deverill, Mark; Bonner, Stephen; Hugill, Keith; Howard, Philip; Henderson, Andrea; Roy, Alistair; Furneval, Julie; Baudouin, Simon V

    2015-05-25

    Patients discharged from Critical Care suffer from excessive longer term morbidity and mortality. Physical and mental health measures of quality of life show a marked and immediate fall after admission to Critical Care with some recovery over time. However, physical function is still significantly reduced at 6 months. The National Institute for Health and Care Excellence clinical guideline on rehabilitation after critical illness, identified the need for high-quality randomised controlled trials to determine the most effective rehabilitation strategy for critically ill patients at risk of critical illness-associated physical morbidity. In response to this, we will conduct a randomised controlled trial, comparing physiotherapy aimed at early and intensive patient mobilisation with routine care. We hypothesise that this intervention will improve physical outcomes and the mental health and functional well-being of survivors of critical illness. 308 adult patients who have received more than 48 h of non-invasive or invasive ventilation in Critical Care will be recruited to a patient-randomised, parallel group, controlled trial, comparing two intensities of physiotherapy. Participants will be randomised to receive either standard or intensive physiotherapy for the duration of their Critical Care admission. Outcomes will be recorded on Critical Care discharge, at 3 and 6 months following initial recruitment to the study. The primary outcome measure is physical health at 6 months, as measured by the SF-36 Physical Component Summary. Secondary outcomes include assessment of mental health, activities of daily living, delirium and ventilator-free days. We will also include a health economic analysis. The trial has ethical approval from Newcastle and North Tyneside 2 Research Ethics Committee (11/NE/0206). There is a Trial Oversight Committee including an independent chair. The results of the study will be submitted for publication in peer-reviewed journals and

  3. Comparative effectiveness of a complex Ayurvedic treatment and conventional standard care in osteoarthritis of the knee – study protocol for a randomized controlled trial

    Science.gov (United States)

    2013-01-01

    Background Traditional Indian Ayurvedic medicine uses complex treatment approaches, including manual therapies, lifestyle and nutritional advice, dietary supplements, medication, yoga, and purification techniques. Ayurvedic strategies are often used to treat osteoarthritis (OA) of the knee; however, no systematic data are available on their effectiveness in comparison with standard care. The aim of this study is to evaluate the effectiveness of complex Ayurvedic treatment in comparison with conventional methods of treating OA symptoms in patients with knee osteoarthritis. Methods and design In a prospective, multicenter, randomized controlled trial, 150 patients between 40 and 70 years, diagnosed with osteoarthritis of the knee, following American College of Rheumatology criteria and an average pain intensity of ≥40 mm on a 100 mm visual analog scale in the affected knee at baseline will be randomized into two groups. In the Ayurveda group, treatment will include tailored combinations of manual treatments, massages, dietary and lifestyle advice, consideration of selected foods, nutritional supplements, yoga posture advice, and knee massage. Patients in the conventional group will receive self-care advice, pain medication, weight-loss advice (if overweight), and physiotherapy following current international guidelines. Both groups will receive 15 treatment sessions over 12 weeks. Outcomes will be evaluated after 6 and 12 weeks and 6 and 12 months. The primary endpoint is a change in the score on the Western Ontario and McMaster University Osteoarthritis Index (WOMAC) after 12 weeks. Secondary outcome measurements will use WOMAC subscales, a pain disability index, a visual analog scale for pain and sleep quality, a pain experience scale, a quality-of-life index, a profile of mood states, and Likert scales for patient satisfaction, patient diaries, and safety. Using an adapted PRECIS scale, the trial was identified as lying mainly in the middle of the efficacy

  4. No gold standard estimation of the sensitivity and specificity of two molecular diagnostic protocols for Trypanosoma brucei spp. in Western Kenya.

    Directory of Open Access Journals (Sweden)

    Barend Mark de Clare Bronsvoort

    2010-01-01

    Full Text Available African animal trypanosomiasis is caused by a range of tsetse transmitted protozoan parasites includingTrypanosoma vivax, Trypanosoma congolense and Trypansoma brucei. In Western Kenya and other parts of East Africa two subspecies of T. brucei, T.b. brucei and the zoonoticT.b. rhodesiense, co-circulate in livestock. A range of polymerase chain reactions (PCR have been developed as important molecular diagnostic tools for epidemiological investigations of T. brucei s.l. in the animal reservoir and of its zoonotic potential. Quantification of the relative performance of different diagnostic PCRs is essential to ensure comparability of studies. This paper describes an evaluation of two diagnostic test systems for T. brucei using a T. brucei s.l. specific PCR [1] and a single nested PCR targeting the Internal Transcribed Spacer (ITS regions of trypanosome ribosomal DNA [2]. A Bayesian formulation of the Hui-Walter latent class model was employed to estimate their test performance in the absence of a gold standard test for detecting T.brucei s.l. infections in ear-vein blood samples from cattle, pig, sheep and goat populations in Western Kenya, stored on Whatman FTA cards. The results indicate that the system employing the T. brucei s.l. specific PCR (Se1=0.760 had a higher sensitivity than the ITS-PCR (Se2=0.640; both have high specificity (Sp1=0.998; Sp2=0.997. The true prevalences for livestock populations were estimated (pcattle=0.091, ppigs=0.066, pgoats=0.005, psheep=0.006, taking into account the uncertainties in the specificity and sensitivity of the two test systems. Implications of test performance include the required survey sample size; due to its higher sensitivity and specificity, the T. brucei s.l. specific PCR requires a consistently smaller sample size than the ITS-PCR for the detection of T. brucei s.l. However the ITS-PCR is able to simultaneously screen samples for other pathogenic trypanosomes and may thus be, overall, a better

  5. Use of a standardized protocol to identify factors affecting the efficiency of artificial insemination services for cattle through progesterone measurement in fourteen countries

    International Nuclear Information System (INIS)

    Garcia, M.; Goodger, W.J.; Bennett, T.; Perera, B.M.A.O.

    2001-01-01

    The aim of this co-ordinated research project (CRP) was to quantify the main factors limiting the efficiency of artificial insemination (AI) services in cattle under the prevailing conditions of developing countries, in order to recommend suitable strategies for improving conception rates (CR) and the level of usage of AI by cattle farmers. A standardized approach was used in 14 countries over a five-year period (1995-1999). The countries were: Bangladesh, China, Indonesia, Myanmar, Pakistan, Sri Lanka and Vietnam in Asia; and Argentina, Chile, Costa Rica, Cuba, Peru, Uruguay and Venezuela in Latin America. A minimum of 500 cows undergoing first insemination after calving were expected to be monitored in each country. Data regarding farms, AI technicians, semen used, cow inseminated, characteristics of the heat expression and factors related to the insemination were recorded. Three milk samples (or blood samples for dairy heifers and beef cows) were collected for each service to measure progesterone by radioimmunoassay. These were collected on the day of service (day 0) and on days 10-12 and 22-24 after service. Field and laboratory data were recorded in the computer package AIDA (Artificial Insemination Database Application) which was developed for this CRP. The study established the current status of AI services at selected locations in participating countries and showed important differences between Asian and Latin American farming systems. The mean (±s.d.) of the interval from calving to first service for 7992 observations was 120.0 ± 82.1 days (median 95 days) with large differences between countries (P<0.05). The overall CR to first service was 40.9% (n=8196), the most efficient AI services being the ones in Vietnam (62.1%), Chile (61.9%) and Myanmar (58.9%). The interval between the first and second service was 44.6 ± 44.4 days (n=1959). Progesterone data in combination with clinical findings showed that 17.3% of the services were performed in non

  6. Study protocol

    DEFF Research Database (Denmark)

    Smith, Benjamin E; Hendrick, Paul; Bateman, Marcus

    2017-01-01

    avoidance behaviours, catastrophising, self-efficacy, sport and leisure activity participation, and general quality of life. Follow-up will be 3 and 6 months. The analysis will focus on descriptive statistics and confidence intervals. The qualitative components will follow a thematic analysis approach....... DISCUSSION: This study will evaluate the feasibility of running a definitive large-scale trial on patients with patellofemoral pain, within the NHS in the UK. We will identify strengths and weaknesses of the proposed protocol and the utility and characteristics of the outcome measures. The results from...... this study will inform the design of a multicentre trial. TRIAL REGISTRATION: ISRCTN35272486....

  7. A cross-layer communication framework for wireless networked control systems

    NARCIS (Netherlands)

    Israr, N.; Scanlon, W.G.; Irwin, G.W.

    2009-01-01

    This paper presents a robust, dynamic cross-layer wireless communication architecture for wireless networked control systems. Each layer in the proposed protocol architecture contributes to the overall goal of reliable, energy efficient communication. The protocol stack also features a

  8. Interoperability and Reliability of Multiplatform MPLS VPN: Comparison of Traffic Engineering with RSVP-TE Protocol and LDP Protocol

    Directory of Open Access Journals (Sweden)

    Nanang Ismail

    2017-10-01

    48% of packet loss per 100 sent packets while on RSVP packet loss percentage is 35.5% per 100 sent packets. Both protocols have interoperability on the third layer of multiplatform MPLS VPN, but on heavy loaded traffic condition, RSVP protocol has better reliability than the LDP protocol.

  9. Multimode Communication Protocols Enabling Reconfigurable Radios

    Directory of Open Access Journals (Sweden)

    Berlemann Lars

    2005-01-01

    Full Text Available This paper focuses on the realization and application of a generic protocol stack for reconfigurable wireless communication systems. This focus extends the field of software-defined radios which usually concentrates on the physical layer. The generic protocol stack comprises common protocol functionality and behavior which are extended through specific parts of the targeted radio access technology. This paper considers parameterizable modules of basic protocol functions residing in the data link layer of the ISO/OSI model. System-specific functionality of the protocol software is realized through adequate parameterization and composition of the generic modules. The generic protocol stack allows an efficient realization of reconfigurable protocol software and enables a completely reconfigurable wireless communication system. It is a first step from side-by-side realized, preinstalled modes in a terminal towards a dynamic reconfigurable anymode terminal. The presented modules of the generic protocol stack can also be regarded as a toolbox for the accelerated and cost-efficient development of future communication protocols.

  10. Beyond protocols

    DEFF Research Database (Denmark)

    Vanderhoeven, Sonia; Branquart, Etienne; Casaer, Jim

    2017-01-01

    Risk assessment tools for listing invasive alien species need to incorporate all available evidence and expertise. Beyond the wealth of protocols developed to date, we argue that the current way of performing risk analysis has several shortcomings. In particular, lack of data on ecological impact...... information on risk and the exploration of improved methods for decision making on biodiversity management. This is crucial for efficient conservation resource allocation and uptake by stakeholders and the public......., transparency and repeatability of assessments as well as the incorporation of uncertainty should all be explicitly considered. We recommend improved quality control of risk assessments through formalized peer review with clear feedback between assessors and reviewers. Alternatively, a consensus building...

  11. PERFECTED enhanced recovery (PERFECT-ER) care versus standard acute care for patients admitted to acute settings with hip fracture identified as experiencing confusion: study protocol for a feasibility cluster randomized controlled trial.

    Science.gov (United States)

    Hammond, Simon P; Cross, Jane L; Shepstone, Lee; Backhouse, Tamara; Henderson, Catherine; Poland, Fiona; Sims, Erika; MacLullich, Alasdair; Penhale, Bridget; Howard, Robert; Lambert, Nigel; Varley, Anna; Smith, Toby O; Sahota, Opinder; Donell, Simon; Patel, Martyn; Ballard, Clive; Young, John; Knapp, Martin; Jackson, Stephen; Waring, Justin; Leavey, Nick; Howard, Gregory; Fox, Chris

    2017-12-04

    Health and social care provision for an ageing population is a global priority. Provision for those with dementia and hip fracture has specific and growing importance. Older people who break their hip are recognised as exceptionally vulnerable to experiencing confusion (including but not exclusively, dementia and/or delirium and/or cognitive impairment(s)) before, during or after acute admissions. Older people experiencing hip fracture and confusion risk serious complications, linked to delayed recovery and higher mortality post-operatively. Specific care pathways acknowledging the differences in patient presentation and care needs are proposed to improve clinical and process outcomes. This protocol describes a multi-centre, feasibility, cluster-randomised, controlled trial (CRCT) to be undertaken across ten National Health Service hospital trusts in the UK. The trial will explore the feasibility of undertaking a CRCT comparing the multicomponent PERFECTED enhanced recovery intervention (PERFECT-ER), which acknowledges the differences in care needs of confused older patients experiencing hip fracture, with standard care. The trial will also have an integrated process evaluation to explore how PERFECT-ER is implemented and interacts with the local context. The study will recruit 400 hip fracture patients identified as experiencing confusion and will also recruit "suitable informants" (individuals in regular contact with participants who will complete proxy measures). We will also recruit NHS professionals for the process evaluation. This mixed methods design will produce data to inform a definitive evaluation of the intervention via a large-scale pragmatic randomised controlled trial (RCT). The trial will provide a preliminary estimate of potential efficacy of PERFECT-ER versus standard care; assess service delivery variation, inform primary and secondary outcome selection, generate estimates of recruitment and retention rates, data collection difficulties, and

  12. Continuous training and certification in neonatal resuscitation in remote areas using a multi-platform information and communication technology intervention, compared to standard training: A randomized cluster trial study protocol [version 3; referees: 2 approved

    Directory of Open Access Journals (Sweden)

    Carlos Alberto Delgado

    2018-03-01

    Full Text Available Background: About 10% of all newborns may have difficulty breathing and require support by trained personnel. In Peru, 90% of deliveries occur in health facilities. However, there is not a national neonatal resuscitation and certification program for the public health sector. In addition, the Andes and the Amazon regions concentrate large rural remote areas, which further limit the implementation of training programs and the accomplishment of continuous certification. Neonatal resuscitation training through the use of information, communication and technology (ICT tools running on computers, tablets or mobile phones, may overcome such limitations. This strategy allows online and offline access to educational resources, paving the way to more frequent and efficient training and certification processes. Objective: To evaluate the effects of a neonatal resuscitation training and certification program that uses a multi-platform ICT (MP-ICT strategy on neonatal health care in remote areas. Methods: We propose to conduct the study through a cluster-randomized trial, where the study and analysis unit is the health care facility. Eligible facilities will include primary and secondary health care level facilities that are located in provinces with neonatal mortality rates higher than 15 per 1,000 live births. We will compare the proportion of newborns with a heart rate ≥100 beats per minute at two minutes after birth in health care facilities that receive MP-ICT training and certification implementation, with those that receive standard training and certification. Discussion: We expect that the intervention will be shown as more effective than the current standard of care. We are prepared to include it within a national neonatal resuscitation training and certification program to be implemented at national scale together with policymakers and other key stakeholders.  Trial registration: ClinicalTrials.gov Nº NCT03210194  Status of the study: This

  13. Streetlight Control System Based on Wireless Communication over DALI Protocol

    Science.gov (United States)

    Bellido-Outeiriño, Francisco José; Quiles-Latorre, Francisco Javier; Moreno-Moreno, Carlos Diego; Flores-Arias, José María; Moreno-García, Isabel; Ortiz-López, Manuel

    2016-01-01

    Public lighting represents a large part of the energy consumption of towns and cities. Efficient management of public lighting can entail significant energy savings. This work presents a smart system for managing public lighting networks based on wireless communication and the DALI protocol. Wireless communication entails significant economic savings, as there is no need to install new wiring and visual impacts and damage to the facades of historical buildings in city centers are avoided. The DALI protocol uses bidirectional communication with the ballast, which allows its status to be controlled and monitored at all times. The novelty of this work is that it tackles all aspects related to the management of public lighting: a standard protocol, DALI, was selected to control the ballast, a wireless node based on the IEEE 802.15.4 standard with a DALI interface was designed, a network layer that considers the topology of the lighting network has been developed, and lastly, some user-friendly applications for the control and maintenance of the system by the technical crews of the different towns and cities have been developed. PMID:27128923

  14. Streetlight Control System Based on Wireless Communication over DALI Protocol

    Directory of Open Access Journals (Sweden)

    Francisco José Bellido-Outeiriño

    2016-04-01

    Full Text Available Public lighting represents a large part of the energy consumption of towns and cities. Efficient management of public lighting can entail significant energy savings. This work presents a smart system for managing public lighting networks based on wireless communication and the DALI protocol. Wireless communication entails significant economic savings, as there is no need to install new wiring and visual impacts and damage to the facades of historical buildings in city centers are avoided. The DALI protocol uses bidirectional communication with the ballast, which allows its status to be controlled and monitored at all times. The novelty of this work is that it tackles all aspects related to the management of public lighting: a standard protocol, DALI, was selected to control the ballast, a wireless node based on the IEEE 802.15.4 standard with a DALI interface was designed, a network layer that considers the topology of the lighting network has been developed, and lastly, some user-friendly applications for the control and maintenance of the system by the technical crews of the different towns and cities have been developed.

  15. Streetlight Control System Based on Wireless Communication over DALI Protocol.

    Science.gov (United States)

    Bellido-Outeiriño, Francisco José; Quiles-Latorre, Francisco Javier; Moreno-Moreno, Carlos Diego; Flores-Arias, José María; Moreno-García, Isabel; Ortiz-López, Manuel

    2016-04-27

    Public lighting represents a large part of the energy consumption of towns and cities. Efficient management of public lighting can entail significant energy savings. This work presents a smart system for managing public lighting networks based on wireless communication and the DALI protocol. Wireless communication entails significant economic savings, as there is no need to install new wiring and visual impacts and damage to the facades of historical buildings in city centers are avoided. The DALI protocol uses bidirectional communication with the ballast, which allows its status to be controlled and monitored at all times. The novelty of this work is that it tackles all aspects related to the management of public lighting: a standard protocol, DALI, was selected to control the ballast, a wireless node based on the IEEE 802.15.4 standard with a DALI interface was designed, a network layer that considers the topology of the lighting network has been developed, and lastly, some user-friendly applications for the control and maintenance of the system by the technical crews of the different towns and cities have been developed.

  16. SU-G-TeP2-03: Comparison of Standard Dosimetry Protocol in Japan and AAPM TG-51 Addendum in Order to Establish Optimal Dosimetry for FFF Beam

    Energy Technology Data Exchange (ETDEWEB)

    Matsunaga, T; Adachi, Y [Department of Radiology, Seirei Hamamatsu General Hospital, Hamamatsu, Shizuoka (Japan); Hayashi, N [Graduate School of Health Sciences, Fujita Health University, Tayoake, Aichi (Japan); Nozue, M [Department of Radiation Oncology, Seirei Hamamtsu General Hospital, Hamamatsu, Shizuoka (Japan)

    2016-06-15

    Purpose: Japan Standard Dosimetry of Absorbed dose to water in external beam radiotherapy (JSDP12) is widely used to measure radiation dose in radiotherapy. However, JSDP12 does not take flattening-filter-free (FFF) beam into consideration. In addition, JSDP12 applied TPR20,10 for dose quality index for photon beam. The purpose of this study is to compare JSDP12 with AAPM TG-51 addendum in order to establish optimal dosimetry procedure for FFF beam. Method: We evaluated the ion-recombination factor (ks) and the correction factor of radial beam profile (Prp) in FFF beam dosimetry. The ks was introduced by 2 voltages method and verified by Jaffe’s plot. The Prp was given by both film measurement and calculation of treatment planning system, and compared them. Next, we compared the dose quality indexes (kQ) between TPR20,10 method and PDD(10)x method. Finally we considered optimal dosimetry protocol for FFF photon beam using JSDP12 with referring TG-51 addendum protocols. The FFF photon beams of 6 MV (6X-FFF) and 10 MV (10X-FFF) from TrueBeam were investigated in this study. Results: The ks for 6X-FFF and 10X-FFF beams were 1.005 and 1.010, respectively. The Prp of 0.6 cc ionization chamber for 6X-FFF and 10X-FFF beams (Film, TPS) were (1.004, 1.008) and (1.005, 1.008), respectively. The kQ for 6X-FFF and 10X-FFF beams (JSDP12, TG-51 addendum) were (0.9950, 0.9947) and (0.9851, 0.9845), respectively. The most effective factor for uncertainty in FFF photon beam measurement was Prp for JSDP12 formalism. Total dosimetric differences between JSDP12 and TG-51 addendum for 6X-FFF and 10X-FFF were -0.47% and -0.73%, respectively. Conclusion: The total dosimetric difference between JSDP12 and TG-51 addendum was within 1%. The introduction of kQ given by JSDP is feasible for FFF photon beam dosimetry. However, we think Prp should be considered for optimal dosimetry procedure even if JSDP12 is used for FFF photon beam dosimetry.

  17. CBHRP: A Cluster Based Routing Protocol for Wireless Sensor Network

    OpenAIRE

    Rashed, M. G.; Kabir, M. Hasnat; Rahim, M. Sajjadur; Ullah, Sk. Enayet

    2012-01-01

    A new two layer hierarchical routing protocol called Cluster Based Hierarchical Routing Protocol (CBHRP) is proposed in this paper. It is an extension of LEACH routing protocol. We introduce cluster head-set idea for cluster-based routing where several clusters are formed with the deployed sensors to collect information from target field. On rotation basis, a head-set member receives data from the neighbor nodes and transmits the aggregated results to the distance base station. This protocol ...

  18. Redundancy scheme for multi-layered accelerator control system

    International Nuclear Information System (INIS)

    Chauhan, Amit; Fatnani, Pravin

    2009-01-01

    The control system for SRS Indus-2 has three-layered architecture. There are VMEbus based stations at the lower two layers that are controlled by their respective CPU board. The 'Profibus' fieldbus standard is used for communication between these VME stations distributed in the field. There is a Profibus controller board at each station to implement the communication protocol. The mode of communication is master-slave (command-response) type. This paper proposes a scheme to implement redundancy at the lower two layers namely Layer-2 (Supervisory Layer / Profibus-master) and Layer-3 (Equipment Unit Interface Layer / Profibus-slave). The redundancy is for both the CPU and the communication board. The scheme uses two CPU boards and two Profi controller boards at each L-3 station. This helps in decreasing any downtime resulting either from CPU faults or communication board faults that are placed in the field area. Redundancy of Profi boards provides two active communication channels between the stations that can be used in different ways thereby increasing the availability on a communication link. Redundancy of CPU boards provides certain level of auto fault-recovery as one CPU remains active and the other CPU remains in standby mode, which takes over the control of VMEbus in case of any fault in the main CPU. (author)

  19. Publication trends of study protocols in rehabilitation.

    Science.gov (United States)

    Jesus, Tiago S; Colquhoun, Heather L

    2017-09-04

    Growing evidence points for the need to publish study protocols in the health field. To observe whether the growing interest in publishing study protocols in the broader health field has been translated into increased publications of rehabilitation study protocols. Observational study using publication data and its indexation in PubMed. Not applicable. Not applicable. PubMed was searched with appropriate combinations of Medical Subject Headings up to December 2014. The effective presence of study protocols was manually screened. Regression models analyzed the yearly growth of publications. Two-sample Z-tests analyzed whether the proportion of Systematic Reviews (SRs) and Randomized Controlled Trials (RCTs) among study protocols differed from that of the same designs for the broader rehabilitation research. Up to December 2014, 746 publications of rehabilitation study protocols were identified, with an exponential growth since 2005 (r2=0.981; p<0.001). RCT protocols were the most common among rehabilitation study protocols (83%), while RCTs were significantly more prevalent among study protocols than among the broader rehabilitation research (83% vs. 35.8%; p<0.001). For SRs, the picture was reversed: significantly less common among study protocols (2.8% vs. 9.3%; p<0.001). Funding was more often reported by rehabilitation study protocols than the broader rehabilitation research (90% vs. 53.1%; p<0.001). Rehabilitation journals published a significantly lower share of rehabilitation study protocols than they did for the broader rehabilitation research (1.8% vs.16.7%; p<0.001). Identifying the reasons for these discrepancies and reverting unwarranted disparities (e.g. low rate of publication for rehabilitation SR protocols) are likely new avenues for rehabilitation research and its publication. SRs, particularly those aggregating RCT results, are considered the best standard of evidence to guide rehabilitation clinical practice; however, that standard can be improved

  20. Performance Evaluation of Security Protocols

    DEFF Research Database (Denmark)

    Bodei, Chiara; Buchholtz, Mikael; Curti, Michele

    2005-01-01

    We use a special operational semantics which drives us in inferring quantitative measures on systems describing cryptographis cryptographic protocols. We assign rates to transitions by only looking at these labels. The rates reflect the distributed architecture running applications and the use...... of possibly different cryptosystems. We then map transition systems to Markov chains and evaluate performance of systems, using standard tools....

  1. Protocol and Topology Issues for Wide-Area Satellite Interconnection of Terrestrial Optical LANs

    Science.gov (United States)

    Parraga, N.

    2002-01-01

    Apart from broadcasting, the satellite business is targeting niche markets. Wide area interconnection is considered as one of these niche markets, since it addresses operators and business LANs (B2B, business to business) in remote areas where terrestrial infrastructure is not available. These LANs - if high-speed - are typically based on optical networks such as SONET. One of the advantages of SONET is its architecture flexibility and capacity to transport all kind of applications including multimedia with a range of different transmission rates. The applications can be carried by different protocols among which the Internet Protocol (IP) or the Asynchronous Transfer Mode (ATM) are the most prominent ones. Thus, the question arises how these protocols can be interconnected via the satellite segment. The paper addresses several solutions for interworking with different protocols. For this investigation we distinguish first of all between the topology and the switching technology of the satellites. In case of a star network with transparent satellite, the satellite protocol consists of physical layer and data layer which can be directly interconnected with layer 2 interworking function to their terrestrial counterparts in the SONET backbone. For regenerative satellites the situation is more complex: here we need to distinguish the types of transport protocols being used in the terrestrial and satellite segment. Whereas IP, ATM, MPEG dominate in the terrestrial networks, satellite systems usually do not follow these standards. Some might employ minor additions (for instance, satellite specific packet headers), some might be completely proprietary. In general, interworking must be done for the data plane on top of layer 2 (data link layer), whereas for the signaling plane the interworking is on top of layer 3. In the paper we will discuss the protocol stacks for ATM, IP, and MPEG with a regenerative satellite system. As an example we will use the EuroSkyWay satellite

  2. Comparison of 3- and 20-Gradient Direction Diffusion-Weighted Imaging in a Clinical Subacute Cohort of Patients with Transient Ischemic Attack: Application of Standard Vendor Protocols for Lesion Detection and Final Infarct Size Projection

    Directory of Open Access Journals (Sweden)

    Inger Havsteen

    2017-12-01

    Full Text Available ObjectiveDiffusion tensor imaging may aid brain ischemia assessment but is more time consuming than conventional diffusion-weighted imaging (DWI. We compared 3-gradient direction DWI (3DWI and 20-gradient direction DWI (20DWI standard vendor protocols in a hospital-based prospective cohort of patients with transient ischemic attack (TIA for lesion detection, lesion brightness, predictability of persisting infarction, and final infarct size.MethodsWe performed 3T-magnetic resonance imaging including diffusion and T2-fluid attenuated inversion recovery (FLAIR within 72 h and 8 weeks after ictus. Qualitative lesion brightness was assessed by visual inspection. We measured lesion area and brightness with manual regions of interest and compared with homologous normal tissue.Results117 patients with clinical TIA showed 78 DWI lesions. 2 lesions showed only on 3DWI. No lesions were uniquely 20DWI positive. 3DWI was visually brightest for 34 lesions. 12 lesions were brightest on 20DWI. The median 3DWI lesion area was larger for lesions equally bright, or brightest on 20DWI [median (IQR 39 (18–95 versus 18 (10–34 mm2, P = 0.007]. 3DWI showed highest measured relative lesion signal intensity [median (IQR 0.77 (0.48–1.17 versus 0.58 (0.34–0.81, P = 0.0006]. 3DWI relative lesion signal intensity was not correlated to absolute signal intensity, but 20DWI performed less well for low-contrast lesions. 3DWI lesion size was an independent predictor of persistent infarction. 3-gradient direction apparent diffusion coefficient areas were closest to 8-week FLAIR infarct size.Conclusion3DWI detected more lesions and had higher relative lesion SI than 20DWI. 20DWI appeared blurred and did not add information.Clinical Trial Registrationhttp://www.clinicaltrials.gov. Unique Identifier NCT01531946.

  3. Emulation of Industrial Control Field Device Protocols

    Science.gov (United States)

    2013-03-01

    today. The protocol operates at the application layer of the open systems interconnection ( OSI ) model, meaning it operates independently of the...the OSI model. Their job is to receive serial data from an MTU in the Modbus RTU or ASCII protocol, encapsulate and transmit the data to another modem...facing connection and out-of-band logging capabilities over the other LAN -facing connection. Despite the fact that the hardware configuration of the

  4. A Pattern Language for Designing Application-Level Communication Protocols and the Improvement of Computer Science Education through Cloud Computing

    OpenAIRE

    Lascano, Jorge Edison

    2017-01-01

    Networking protocols have been developed throughout time following layered architectures such as the Open Systems Interconnection model and the Internet model. These protocols are grouped in the Internet protocol suite. Most developers do not deal with low-level protocols, instead they design application-level protocols on top of the low-level protocol. Although each application-level protocol is different, there is commonality among them and developers can apply lessons learned from one prot...

  5. TOOL: The Open Opinion Layer

    OpenAIRE

    Masum, Hassan

    2002-01-01

    Shared opinions drive society: what we read, how we vote, and where we shop are all heavily influenced by the choices of others. However, the cost in time and money to systematically share opinions remains high, while the actual performance history of opinion generators is often not tracked. This article explores the development of a distributed open opinion layer, which is given the generic name of TOOL. Similar to the evolution of network protocols as an underlying layer for many comput...

  6. Comparison of National and International Standards of Good Egg Production Practices

    Directory of Open Access Journals (Sweden)

    GP Sousa

    Full Text Available ABSTRACT Egg production is an important economic activity in Brazil, with about 697 million eggs produced annually. The conventional cage system is commonly used for egg production. However, there has been a growing concern for the welfare of laying hens around the world. In this context, many countries have issued laws, protocols, and other normative technical specifications to ensure the welfare of layers. This study aims at identifying similarities and differences between international standards and Brazilian protocols using the Comparative Law perspective. This article reports an analytical study of selected protocols, performing three analyses using the Comparative Law method. The research concludes that some items of the Brazilian protocols of good egg production practices, such as farm inspection, treatment of diseases, temperature, ventilation, beak trimming, feed and water supply, correspond to international specifications, whereas others, such as housing, freedom movement, use of equipment, and transport, are less strict.

  7. TULIP: A Link-Level Protocol for Improving TCP over Wireless Links

    National Research Council Canada - National Science Library

    Parsa, Christina; Garcia-Luna-Aceves, J. J

    1999-01-01

    We present the transport unaware link improvement protocol (TULIP), which dramatically improves the performance of TCP over lossy wireless links, without competing with or modifying the transport- or network-layer protocols...

  8. The SIMS trial: adjustable anchored single-incision mini-slings versus standard tension-free midurethral slings in the surgical management of female stress urinary incontinence. A study protocol for a pragmatic, multicentre, non-inferiority randomised controlled trial.

    Science.gov (United States)

    Abdel-Fattah, Mohamed; MacLennan, Graeme; Kilonzo, Mary; Assassa, R Phil; McCormick, Kirsty; Davidson, Tracey; McDonald, Alison; N'Dow, James; Wardle, Judith; Norrie, John

    2017-08-11

    Single-incision mini-slings (SIMS) represent the third generation of midurethral slings. They have been developed with the aim of offering a true ambulatory procedure for treatment of female stress urinary incontinence (SUI) with reduced morbidity and earlier recovery while maintaining similar efficacy to standard midurethral slings (SMUS). The aim of this study is to determine the clinical and cost-effectiveness of adjustable anchored SIMS compared with tension-free SMUS in the surgical management of female SUI, with 3-year follow-up. A pragmatic, multicentre, non-inferiority randomised controlled trial. The primary outcome measure is the patient-reported success rate measured by the Patient Global Impression of Improvement at 12 months. The primary economic outcome will be incremental cost per quality-adjusted life year gained at 12 months. The secondary outcomes measures include adverse events, objective success rates, impact on other lower urinary tract symptoms, health-related quality of life profile and sexual function, and reoperation rates for SUI. Secondary economic outcomes include National Health Service and patient primary and secondary care resource use and costs, incremental cost-effectiveness and incremental net benefit. The statistical analysis of the primary outcome will be by intention-to-treat and also a per-protocol analysis. Results will be displayed as estimates and 95% CIs. CIs around observed differences will then be compared with the prespecified non-inferiority margin. Secondary outcomes will be analysed similarly. The North of Scotland Research Ethics Committee has approved this study (13/NS/0143). The dissemination plans include HTA monograph, presentation at international scientific meetings and publications in high-impact, open-access journals. The results will be included in the updates of the National Institute for Health and Care Excellence and the European Association of Urology guidelines; these two specific guidelines directly

  9. Effects of tailored neck-shoulder pain treatment based on a decision model guided by clinical assessments and standardized functional tests. A study protocol of a randomized controlled trial

    Directory of Open Access Journals (Sweden)

    Björklund Martin

    2012-05-01

    Full Text Available Abstract Background A major problem with rehabilitation interventions for neck pain is that the condition may have multiple causes, thus a single treatment approach is seldom efficient. The present study protocol outlines a single blinded randomised controlled trial evaluating the effect of tailored treatment for neck-shoulder pain. The treatment is based on a decision model guided by standardized clinical assessment and functional tests with cut-off values. Our main hypothesis is that the tailored treatment has better short, intermediate and long-term effects than either non-tailored treatment or treatment-as-usual (TAU on pain and function. We sub-sequentially hypothesize that tailored and non-tailored treatment both have better effect than TAU. Methods/Design 120 working women with minimum six weeks of nonspecific neck-shoulder pain aged 20–65, are allocated by minimisation with the factors age, duration of pain, pain intensity and disability in to the groups tailored treatment (T, non-tailored treatment (NT or treatment-as-usual (TAU. Treatment is given to the groups T and NT for 11 weeks (27 sessions evenly distributed. An extensive presentation of the tests and treatment decision model is provided. The main treatment components are manual therapy, cranio-cervical flexion exercise and strength training, EMG-biofeedback training, treatment for cervicogenic headache, neck motor control training. A decision algorithm based on the baseline assessment determines the treatment components given to each participant of T- and NT-groups. Primary outcome measures are physical functioning (Neck Disability Index and average pain intensity last week (Numeric Rating Scale. Secondary outcomes are general improvement (Patient Global Impression of Change scale, symptoms (Profile Fitness Mapping neck questionnaire, capacity to work in the last 6 weeks (quality and quantity and pressure pain threshold of m. trapezius. Primary and secondary outcomes will

  10. On consensus through communication without a commonly known protocol

    OpenAIRE

    Tsakas Elias; Voorneveld Mark

    2010-01-01

    The present paper extends the standard model of pairwise communication among Bayesianagents to cases where the structure of the communication protocol is not commonly known.We show that, even under strict conditions on the structure of the protocols and the nature of the transmitted signals, a consensus may never be reached if very little asymmetric information about the protocol is introduced.

  11. Comparison between the Correlations of Retinal Nerve Fiber Layer Thickness Measured by Spectral Domain Optical Coherence Tomography and Visual Field Defects in Standard Automated White-on-White Perimetry versus Pulsar Perimetry.

    Science.gov (United States)

    Alnawaiseh, Maged; Hömberg, Lisann; Eter, Nicole; Prokosch, Verena

    2017-01-01

    To compare the structure-function relationships between retinal nerve fiber layer thickness (RNFLT) and visual field defects measured either by standard automated perimetry (SAP) or by Pulsar perimetry (PP). 263 eyes of 143 patients were prospectively included. Depending on the RNFLT, patients were assigned to the glaucoma group (group A: RNFL score 3-6) or the control group (group B: RNFL score 0-2). Structure-function relationships between RNFLT and mean sensitivity (MS) measured by SAP and PP were analyzed. Throughout the entire group, the MS assessed by PP and SAP correlated significantly with RNFLT in all sectors. In the glaucoma group, there was no significant difference between the correlations RNFL-SAP and RNFL-PP, whereas a significant difference was found in the control group. In the control group, the correlation between structure and function based on the PP data was significantly stronger than that based on SAP.

  12. Link-layer Jamming Attacks on S-MAC

    NARCIS (Netherlands)

    Law, Y.W.; Hartel, Pieter H.; den Hartog, Jeremy; Havinga, Paul J.M.

    2004-01-01

    We argue that among denial-of-service (DoS) attacks, link-layer jamming is a more attractive option to attackers than radio jamming is. By exploiting the semantics of the link-layer protocol (aka MAC protocol), an attacker can achieve better efficiency than blindly jamming the radio signals alone.

  13. Link-layer jamming attacks on S-MAC

    NARCIS (Netherlands)

    Law, Y.W.; Hartel, Pieter H.; den Hartog, Jeremy; Havinga, Paul J.M.

    We argue that among denial-of-service (DoS) attacks, link-layer jamming is a more attractive option to attackers than radio jamming is. By exploiting the semantics of the link-layer protocol (aka MAC protocol), an attacker can achieve better efficiency than blindly jamming the radio signals alone.

  14. Cross Layer Optimization and Simulation of Smart Grid Home Area Network

    Directory of Open Access Journals (Sweden)

    Lipi K. Chhaya

    2018-01-01

    Full Text Available An electrical “Grid” is a network that carries electricity from power plants to customer premises. Smart Grid is an assimilation of electrical and communication infrastructure. Smart Grid is characterized by bidirectional flow of electricity and information. Smart Grid is a complex network with hierarchical architecture. Realization of complete Smart Grid architecture necessitates diverse set of communication standards and protocols. Communication network protocols are engineered and established on the basis of layered approach. Each layer is designed to produce an explicit functionality in association with other layers. Layered approach can be modified with cross layer approach for performance enhancement. Complex and heterogeneous architecture of Smart Grid demands a deviation from primitive approach and reworking of an innovative approach. This paper describes a joint or cross layer optimization of Smart Grid home/building area network based on IEEE 802.11 standard using RIVERBED OPNET network design and simulation tool. The network performance can be improved by selecting various parameters pertaining to different layers. Simulation results are obtained for various parameters such as WLAN throughput, delay, media access delay, and retransmission attempts. The graphical results show that various parameters have divergent effects on network performance. For example, frame aggregation decreases overall delay but the network throughput is also reduced. To prevail over this effect, frame aggregation is used in combination with RTS and fragmentation mechanisms. The results show that this combination notably improves network performance. Higher value of buffer size considerably increases throughput but the delay is also greater and thus the choice of optimum value of buffer size is inevitable for network performance optimization. Parameter optimization significantly enhances the performance of a designed network. This paper is expected to serve

  15. Protecting the ozone layer.

    Science.gov (United States)

    Munasinghe, M; King, K

    1992-06-01

    Stratospheric ozone layer depletion has been recognized as a problem by the Vienna Convention for the Protection of the Ozone Layer and the 1987 Montreal Protocol (MP). The ozone layer shields the earth from harmful ultraviolet radiation (UV-B), which is more pronounced at the poles and around the equator. Industrialized countries have contributed significantly to the problem by releasing chlorofluorocarbons (CFCs) and halons into the atmosphere. The effect of these chemicals, which were known for their inertness, nonflammability, and nontoxicity, was discovered in 1874. Action to deal with the effects of CFCs and halons was initiated in 1985 in a 49-nation UN meeting. 21 nations signed a protocol limiting ozone depleting substances (ODS): CFCs and halons. Schedules were set based on each country's use in 1986; the target phaseout was set for the year 2000. The MP restricts trade in ODSs and weights the impact of substances to reflect the extent of damage; i.e., halons are 10 times more damaging than CFCs. ODS requirements for developing countries were eased to accommodate scarce resources and the small fraction of ODS emissions. An Interim Multilateral Fund under the Montreal Protocol (IMFMP) was established to provide loans to finance the costs to developing countries in meeting global environmental requirements. The IMFMP is administered by the World Bank, the UN Environmental Program, and the UN Development Program. Financing is available to eligible countries who use .3 kg of ODS/person/year. Rapid phaseout in developed countries has occurred due to strong support from industry and a lower than expected cost. Although there are clear advantages to rapid phaseout, there were no incentives included in the MP for rapid phaseout. Some of the difficulties occur because the schedules set minimum targets at the lowest possible cost. Also, costs cannot be minimized by a country-specific and ODS-specific process. The ways to improve implementation in scheduling and

  16. A universal data access and protocol integration mechanism for smart home

    Science.gov (United States)

    Shao, Pengfei; Yang, Qi; Zhang, Xuan

    2013-03-01

    With the lack of standardized or completely missing communication interfaces in home electronics, there is no perfect solution to address every aspect in smart homes based on existing protocols and technologies. In addition, the central control unit (CCU) of smart home system working point-to-point between the multiple application interfaces and the underlying hardware interfaces leads to its complicated architecture and unpleasant performance. A flexible data access and protocol integration mechanism is required. The current paper offers a universal, comprehensive data access and protocol integration mechanism for a smart home. The universal mechanism works as a middleware adapter with unified agreements of the communication interfaces and protocols, offers an abstraction of the application level from the hardware specific and decoupling the hardware interface modules from the application level. Further abstraction for the application interfaces and the underlying hardware interfaces are executed based on adaption layer to provide unified interfaces for more flexible user applications and hardware protocol integration. This new universal mechanism fundamentally changes the architecture of the smart home and in some way meets the practical requirement of smart homes more flexible and desirable.

  17. Superposition Attacks on Cryptographic Protocols

    DEFF Research Database (Denmark)

    Damgård, Ivan Bjerre; Funder, Jakob Løvstad; Nielsen, Jesper Buus

    2011-01-01

    of information. In this paper, we introduce a fundamentally new model of quantum attacks on classical cryptographic protocols, where the adversary is allowed to ask several classical queries in quantum superposition. This is a strictly stronger attack than the standard one, and we consider the security......Attacks on classical cryptographic protocols are usually modeled by allowing an adversary to ask queries from an oracle. Security is then defined by requiring that as long as the queries satisfy some constraint, there is some problem the adversary cannot solve, such as compute a certain piece...... of several primitives in this model. We show that a secret-sharing scheme that is secure with threshold $t$ in the standard model is secure against superposition attacks if and only if the threshold is lowered to $t/2$. We use this result to give zero-knowledge proofs for all of NP in the common reference...

  18. Optimized UAV Communication Protocol Based on Prior Locations

    OpenAIRE

    Sboui, Lokman; Rabah, Abdullatif

    2015-01-01

    In this paper, we adopt a new communication protocol between the UAV and fixed on-ground nodes. This protocol tends to reduce communication power consumption by stopping communication if the channel is not good to communicate (i.e. far nodes, obstacles, etc.) The communication is performed using the XBee 868M standard and Libelium wapsmotes. Our designed protocol is based on a new communication model that we propose in this paper. The protocole decides wether to communicate or not after compu...

  19. Vertical Protocol Composition

    DEFF Research Database (Denmark)

    Groß, Thomas; Mödersheim, Sebastian Alexander

    2011-01-01

    The security of key exchange and secure channel protocols, such as TLS, has been studied intensively. However, only few works have considered what happens when the established keys are actually used—to run some protocol securely over the established “channel”. We call this a vertical protocol.......e., that the combination cannot introduce attacks that the individual protocols in isolation do not have. In this work, we prove a composability result in the symbolic model that allows for arbitrary vertical composition (including self-composition). It holds for protocols from any suite of channel and application...

  20. Establishment of standard x-ray qualities to be used in diagnostic level at SSDLs

    International Nuclear Information System (INIS)

    A-Aziz, R.O.

    2007-08-01

    The objective of the present work is to modify x-ray machine (used by the secondary standard dosimetry laboratory in Sudan) to produce x-ray qualities suitable for the calibration at diagnostic level. It based on experimental evaluations. The importance of this study appears in development of protocols to calibrate the instruments used in diagnostic radiology in by good response of the instruments and low cost. In particular, the half value layer (HVL) values for the following qualities 40, 60, 80, 100, 120 and 150 were determined using various attenuation layers. Ionization chamber was used to determine the free air kerma rate at a distance of 100 cm from the x-ray generator. The obtained HVL values were compared with standard values of diagnostic levels. It was observed that the HVL of the present x-ray machine in most qualities are smaller than the standard ones. An approved method (described in the standard IEC 61267) was applied to determine the amount of additional filtration required to meet the standard values. The results show that the available cupper layers were not suitable for this purpose as most of the x-ray was absorbed in the material. Aluminum layers, on the other hand , show good performances to reduce the beams to the desired levels. The amount of additional filtration (from aluminum layers) needed in order to establish standard x-ray qualities to be used in diagnostic level were determined.(Author)

  1. Distributed Cross-layer Monitoring in Wireless Mesh Networks

    OpenAIRE

    Panmin, Ye; Yong,

    2009-01-01

    Wireless mesh networks has rapid development over the last few years. However, due to properties such as distributed infrastructure and interference, which strongly affect the performance of wireless mesh networks, developing technology has to face the challenge of architecture and protocol design issues. Traditional layered protocols do not function efficiently in multi-hop wireless environments. To get deeper understanding on interaction of the layered protocols and optimize the performance...

  2. Design and FPGA implementation for MAC layer of Ethernet PON

    Science.gov (United States)

    Zhu, Zengxi; Lin, Rujian; Chen, Jian; Ye, Jiajun; Chen, Xinqiao

    2004-04-01

    Ethernet passive optical network (EPON), which represents the convergence of low-cost, high-bandwidth and supporting multiple services, appears to be one of the best candidates for the next-generation access network. The work of standardizing EPON as a solution for access network is still underway in the IEEE802.3ah Ethernet in the first mile (EFM) task force. The final release is expected in 2004. Up to now, there has been no standard application specific integrated circuit (ASIC) chip available which fulfills the functions of media access control (MAC) layer of EPON. The MAC layer in EPON system has many functions, such as point-to-point emulation (P2PE), Ethernet MAC functionality, multi-point control protocol (MPCP), network operation, administration and maintenance (OAM) and link security. To implement those functions mentioned above, an embedded real-time operating system (RTOS) and a flexible programmable logic device (PLD) with an embedded processor are used. The software and hardware functions in MAC layer are realized through programming embedded microprocessor and field programmable gate array(FPGA). Finally, some experimental results are given in this paper. The method stated here can provide a valuable reference for developing EPON MAC layer ASIC.

  3. Building America House Simulation Protocols

    Energy Technology Data Exchange (ETDEWEB)

    Hendron, Robert [National Renewable Energy Lab. (NREL), Golden, CO (United States); Engebrecht, Cheryn [National Renewable Energy Lab. (NREL), Golden, CO (United States)

    2010-09-01

    The House Simulation Protocol document was developed to track and manage progress toward Building America's multi-year, average whole-building energy reduction research goals for new construction and existing homes, using a consistent analytical reference point. This report summarizes the guidelines for developing and reporting these analytical results in a consistent and meaningful manner for all home energy uses using standard operating conditions.

  4. Simple algorithm for improved security in the FDDI protocol

    Science.gov (United States)

    Lundy, G. M.; Jones, Benjamin

    1993-02-01

    We propose a modification to the Fiber Distributed Data Interface (FDDI) protocol based on a simple algorithm which will improve confidential communication capability. This proposed modification provides a simple and reliable system which exploits some of the inherent security properties in a fiber optic ring network. This method differs from conventional methods in that end to end encryption can be facilitated at the media access control sublayer of the data link layer in the OSI network model. Our method is based on a variation of the bit stream cipher method. The transmitting station takes the intended confidential message and uses a simple modulo two addition operation against an initialization vector. The encrypted message is virtually unbreakable without the initialization vector. None of the stations on the ring will have access to both the encrypted message and the initialization vector except the transmitting and receiving stations. The generation of the initialization vector is unique for each confidential transmission and thus provides a unique approach to the key distribution problem. The FDDI protocol is of particular interest to the military in terms of LAN/MAN implementations. Both the Army and the Navy are considering the standard as the basis for future network systems. A simple and reliable security mechanism with the potential to support realtime communications is a necessary consideration in the implementation of these systems. The proposed method offers several advantages over traditional methods in terms of speed, reliability, and standardization.

  5. Real-time communication protocols: an overview

    NARCIS (Netherlands)

    Hanssen, F.T.Y.; Jansen, P.G.

    2003-01-01

    This paper describes several existing data link layer protocols that provide real-time capabilities on wired networks, focusing on token-ring and Carrier Sense Multiple Access based networks. Existing modifications to provide better real-time capabilities and performance are also described. Finally

  6. Ad hoc mobile wireless networks principles, protocols, and applications

    CERN Document Server

    Sarkar, Subir Kumar

    2013-01-01

    The military, the research community, emergency services, and industrial environments all rely on ad hoc mobile wireless networks because of their simple infrastructure and minimal central administration. Now in its second edition, Ad Hoc Mobile Wireless Networks: Principles, Protocols, and Applications explains the concepts, mechanism, design, and performance of these highly valued systems. Following an overview of wireless network fundamentals, the book explores MAC layer, routing, multicast, and transport layer protocols for ad hoc mobile wireless networks. Next, it examines quality of serv

  7. Nuclear radiation gauge standard

    International Nuclear Information System (INIS)

    Berry, R.L.

    1977-01-01

    A hydrophobic standard for calibrating nuclear radiation moisture gauges is described, comprising a body of superposed interleaved thin layers of a moderating material containing hydrogen in the molecular structure thereof and of a substantially non-moderating material

  8. A software defined RTU multi-protocol automatic adaptation data transmission method

    Science.gov (United States)

    Jin, Huiying; Xu, Xingwu; Wang, Zhanfeng; Ma, Weijun; Li, Sheng; Su, Yong; Pan, Yunpeng

    2018-02-01

    Remote terminal unit (RTU) is the core device of the monitor system in hydrology and water resources. Different devices often have different communication protocols in the application layer, which results in the difficulty in information analysis and communication networking. Therefore, we introduced the idea of software defined hardware, and abstracted the common feature of mainstream communication protocols of RTU application layer, and proposed a uniformed common protocol model. Then, various communication protocol algorithms of application layer are modularized according to the model. The executable codes of these algorithms are labeled by the virtual functions and stored in the flash chips of embedded CPU to form the protocol stack. According to the configuration commands to initialize the RTU communication systems, it is able to achieve dynamic assembling and loading of various application layer communication protocols of RTU and complete the efficient transport of sensor data from RTU to central station when the data acquisition protocol of sensors and various external communication terminals remain unchanged.

  9. Lingual orthodontics for children and adolescents: improvement of the indirect bonding protocol

    Science.gov (United States)

    2013-01-01

    Introduction Demineralization of the dental enamel is a finding associated with fixed orthodontic treatment. When an indirect bonding procedure is used in children and adolescents the area beneath the bracket base may be affected. Aim To evaluate if the addition of an extra layer of a hydrophilic resin, to a conventional indirect bonding protocol, can reduce the incidence of demineralization beneath the bracket base. Methods 40 patients under 18 years of age were treated with completely customized lingual appliances. Two different bonding protocols were used either with or without the application of an additional layer of hydrophilic resin. Demineralization beneath the bracket base, after de-bonding, was evaluated by standardized intra-oral photographs. Results The addition of an extra layer of a hydrophilic resin helps to reduce the number of demineralized areas beneath the bracket bases significantly (three times less). The severity of the few remaining defects were minor and without any clinical consequence. Conclusion When bonding a completely customized lingual appliance in children and adolescents, an extra layer of a hydrophilic resin should be added to the teeth. PMID:24025345

  10. A Comparison Between the OSI Reference Model and the B-ISDN Protocol Reference Model

    DEFF Research Database (Denmark)

    Staalhagen, Lars

    1996-01-01

    This article aims at comparing the Open Systems Interconnection (OSI) Reference Model (RM) and the broadband integrated services digital network (B-ISDN) Protocol Reference Model (PRM). According to the International Telecommunications Union - Telecommunications Sector (ITU-T), the exact...... relationship between the lower layers of the OSI RM and the B-ISDN PRM is for further study. It is therefore the intention of this article to present some views on these relationships which hopefully could facilitate an interconnection between B-ISDN and data networks conforming to the OSI standards....

  11. Field Monitoring Protocol. Heat Pump Water Heaters

    Energy Technology Data Exchange (ETDEWEB)

    Sparn, B. [National Renewable Energy Lab. (NREL), Golden, CO (United States); Earle, L. [National Renewable Energy Lab. (NREL), Golden, CO (United States); Christensen, D. [National Renewable Energy Lab. (NREL), Golden, CO (United States); Maguire, J. [National Renewable Energy Lab. (NREL), Golden, CO (United States); Wilson, E. [National Renewable Energy Lab. (NREL), Golden, CO (United States); Hancock, C. E. [Mountain Energy Partnership, Longmont, CO (United States)

    2013-02-01

    This document provides a standard field monitoring protocol for evaluating the installed performance of Heat Pump Water Heaters in residential buildings. The report is organized to be consistent with the chronology of field test planning and execution. Research questions are identified first, followed by a discussion of analysis methods, and then the details of measuring the required information are laid out. A field validation of the protocol at a house near the NREL campus is included for reference.

  12. Field Monitoring Protocol: Heat Pump Water Heaters

    Energy Technology Data Exchange (ETDEWEB)

    Sparn, B.; Earle, L.; Christensen, D.; Maguire, J.; Wilson, E.; Hancock, E.

    2013-02-01

    This document provides a standard field monitoring protocol for evaluating the installed performance of Heat Pump Water Heaters in residential buildings. The report is organized to be consistent with the chronology of field test planning and execution. Research questions are identified first, followed by a discussion of analysis methods, and then the details of measuring the required information are laid out. A field validation of the protocol at a house near the NREL campus is included for reference.

  13. The French dosimetry protocol

    International Nuclear Information System (INIS)

    Dutreix, A.

    1985-01-01

    After a general introduction the protocol is divided in five sections dealing with: determination of the quality of X-ray, γ-ray and electron beams; the measuring instrument; calibration of the reference instrument; determination of the reference absorbed dose in the user's beams; determination of the absorbed dose in water at other points, in other conditions. The French protocol is not essentially different from the Nordic protocol and it is based on the experience gained in using both the American and the Nordic protocols. Therefore, only the main difference with the published protocols are discussed. (Auth.)

  14. SPP: A data base processor data communications protocol

    Science.gov (United States)

    Fishwick, P. A.

    1983-01-01

    The design and implementation of a data communications protocol for the Intel Data Base Processor (DBP) is defined. The protocol is termed SPP (Service Port Protocol) since it enables data transfer between the host computer and the DBP service port. The protocol implementation is extensible in that it is explicitly layered and the protocol functionality is hierarchically organized. Extensive trace and performance capabilities have been supplied with the protocol software to permit optional efficient monitoring of the data transfer between the host and the Intel data base processor. Machine independence was considered to be an important attribute during the design and implementation of SPP. The protocol source is fully commented and is included in Appendix A of this report.

  15. The Singapore protocol [for quantum cryptography

    International Nuclear Information System (INIS)

    Englert, B.

    2005-01-01

    The qubit protocol for quantum key distribution presented in this talk is fully tomographic and more efficient than other tomographic protocols. Under ideal circumstances the efficiency is log 2 (4/3) = 0.415 key bits per qubit sent, which is 25% more than the efficiency of 1/3 = 0.333 for the standard 6-state protocol. One can extract 0.4 key bits per qubit by a simple two-way communication scheme, and can so get close to the information-theoretical limit. The noise thresholds for secure key bit generation in the presence of unbiased noise will be reported and discussed. (author)

  16. Protocol Implementation Generator

    DEFF Research Database (Denmark)

    Carvalho Quaresma, Jose Nuno; Probst, Christian W.

    2010-01-01

    Users expect communication systems to guarantee, amongst others, privacy and integrity of their data. These can be ensured by using well-established protocols; the best protocol, however, is useless if not all parties involved in a communication have a correct implementation of the protocol and a...... Generator framework based on the LySatool and a translator from the LySa language into C or Java....... necessary tools. In this paper, we present the Protocol Implementation Generator (PiG), a framework that can be used to add protocol generation to protocol negotiation, or to easily share and implement new protocols throughout a network. PiG enables the sharing, verification, and translation...

  17. High-Performance CCSDS AOS Protocol Implementation in FPGA

    Science.gov (United States)

    Clare, Loren P.; Torgerson, Jordan L.; Pang, Jackson

    2010-01-01

    The Consultative Committee for Space Data Systems (CCSDS) Advanced Orbiting Systems (AOS) space data link protocol provides a framing layer between channel coding such as LDPC (low-density parity-check) and higher-layer link multiplexing protocols such as CCSDS Encapsulation Service, which is described in the following article. Recent advancement in RF modem technology has allowed multi-megabit transmission over space links. With this increase in data rate, the CCSDS AOS protocol implementation needs to be optimized to both reduce energy consumption and operate at a high rate.

  18. Advanced dementia pain management protocols.

    Science.gov (United States)

    Montoro-Lorite, Mercedes; Canalias-Reverter, Montserrat

    Pain management in advanced dementia is complex because of neurological deficits present in these patients, and nurses are directly responsible for providing interventions for the evaluation, management and relief of pain for people suffering from this health problem. In order to facilitate and help decision-makers, pain experts recommend the use of standardized protocols to guide pain management, but in Spain, comprehensive pain management protocols have not yet been developed for advanced dementia. This article reflects the need for an integrated management of pain in advanced dementia. From the review and analysis of the most current and relevant studies in the literature, we performed an approximation of the scales for the determination of pain in these patients, with the observational scale PAINAD being the most recommended for the hospital setting. In addition, we provide an overview for comprehensive management of pain in advanced dementia through the conceptual framework «a hierarchy of pain assessment techniques by McCaffery and Pasero» for the development and implementation of standardized protocols, including a four-phase cyclical process (evaluation, planning/performance, revaluation and recording), which can facilitate the correct management of pain in these patients. Copyright © 2017 Elsevier España, S.L.U. All rights reserved.

  19. Black layers on historical architecture.

    Science.gov (United States)

    Toniolo, Lucia; Zerbi, Carlotta M; Bugini, Roberto

    2009-03-01

    The external surface of any building in urban polluted environment is unavoidably destined to be covered with layers that assume a grey to black colour and are generally called 'black crusts'. These, according to standard protocols and glossary, are deteriorated surface layers of stone material; they can have variable thickness, are hard and fragile and can detach spontaneously from the substrate, which, in general, is quite decayed. Plain visual examination may lead to consider 'black crusts' all similar, whilst only a careful diagnostic investigation can distinguish 'black crusts' and the consequences of their formation on stone substrates. In this paper, various black layers on marble are studied and compared and the morphological and compositional characteristics discussed according to the related mechanisms of formation. Differences between old (hundred years) and recent crusts (30 years) are investigated and pointed out. Samples of black crusts collected from the Milan Cathedral façade (Candoglia Marble) have been studied and compared with the careful and synergic employ of traditional techniques: optical (transmission and reflected VIS light) and electron microscopy, X-ray spectrometry and micro-Fourier transform infrared spectroscopy. Visual examination of loose fragments does not allow to point out outstanding differences amongst the various samples; black layers have similar main mineral components, gypsum and airborne particles, with different spatial distribution. The microscopic studies allowed to point out the porosity differences, the gypsum crystallisation habit, different amount of embedded particles, level and progress of marble decay. The observations lead to define three main types of black crusts: black crust deriving from marble sulphation, compact deposit and encrustation due to exogenic materials deposition. Black crusts show evidence of sulphation in progress, without a clear continuity solution between crust and marble; the lack of

  20. Principles of the new quantum cryptography protocols building

    International Nuclear Information System (INIS)

    Kurochkin, V.; Kurochkin, Yu.

    2009-01-01

    The main aim of the quantum cryptography protocols is the maximal secrecy under the conditions of the real experiment. This work presents the result of the new protocol building with the use of the secrecy maximization. While using some well-known approaches this method has allowed one to achieve completely new results in quantum cryptography. The process of the protocol elaboration develops from the standard BB84 protocol upgrading to the building of completely new protocol with arbitrary large bases number. The secrecy proofs of the elaborated protocol appear to be natural continuation of the protocol building process. This approach reveals possibility to reach extremely high parameters of the protocol. It suits both the restrictions of contemporary technologies and requirements for high bit rate while being absolutely secret

  1. Efficacy of standard (SLA) and modified sandblasted and acid-etched (SLActive) dental implants in promoting immediate and/or early occlusal loading protocols: a systematic review of prospective studies.

    Science.gov (United States)

    Chambrone, Leandro; Shibli, Jamil Awad; Mercúrio, Carlos Eduardo; Cardoso, Bruna; Preshaw, Philip M

    2015-04-01

    To assess the survival percentage, clinical and radiographic outcomes of sandblasted and acid-etched (SLA) dental implants and its modified surface (SLActive) in protocols involving immediate and early occlusal loading. MEDLINE, EMBASE and the Cochrane Oral Health Group's Trials Register CENTRAL were searched in duplicate up to, and including, June 2013 to include randomised controlled trials (RCTs) and prospective observational studies of at least 6-month duration published in all languages. Studies limited to patients treated with SLA and/or SLActive implants involving a treatment protocol describing immediate and early loading of these implants were eligible for inclusion. Data on clinical and/or radiographic outcomes following implant placement were considered for inclusion. Of the 447 potentially eligible publications identified by the search strategy, seven RCTs comprising a total of 853 implants (8% titanium plasma-sprayed, 41.5% SLA and 50.5% SLActive) and 12 prospective observational studies including 1394 SLA and 145 SLActive implants were included in this review. According to the Cochrane Collaboration's tool for assessing risk of bias, one of the studies was considered to be at a low risk of bias, whereas the remaining studies were considered to be at an unclear risk. Regarding the observational studies, all of them presented a medium methodological quality based on the Modified Newcastle-Ottawa scale. There were no significant differences reported in the studies in relation to implant loss or clinical parameters between the immediate/early loading and delayed loading protocols. Overall, 95% of SLA and 97% of SLActive implants still survive at the end of follow-up. Despite of the positive findings achieved by the included studies, few RCTs were available for analysis for SLActive implants. Study heterogeneity, scarcity of data and the lack of pooled estimates represent a limitation between studies' comparisons and should be considered when interpreting

  2. Radio protocols for LTE and LTE-advanced

    CERN Document Server

    Yi, SeungJune; Lee, YoungDae; Park, SungJun; Jung, SungHoon

    2012-01-01

    Provides a unique focus on radio protocols for LTE and LTE-Advanced (LTE-A) Giving readers a valuable understanding of LTE radio protocols, this book covers LTE (Long-Term Evolution) Layer 2/3 radio protocols as well as new features including LTE-Advanced. It is divided into two sections to differentiate between the two technologies' characteristics. The authors systematically explain the design principles and functions of LTE radio protocols during the development of mobile handsets. The book also provides essential knowledge on the interaction between mobile networks a

  3. A Weak Value Based QKD Protocol Robust Against Detector Attacks

    Science.gov (United States)

    Troupe, James

    2015-03-01

    We propose a variation of the BB84 quantum key distribution protocol that utilizes the properties of weak values to insure the validity of the quantum bit error rate estimates used to detect an eavesdropper. The protocol is shown theoretically to be secure against recently demonstrated attacks utilizing detector blinding and control and should also be robust against all detector based hacking. Importantly, the new protocol promises to achieve this additional security without negatively impacting the secure key generation rate as compared to that originally promised by the standard BB84 scheme. Implementation of the weak measurements needed by the protocol should be very feasible using standard quantum optical techniques.

  4. Optimization and Verification of the TR-MAC Protocol for Wireless Sensor Networks

    NARCIS (Netherlands)

    Morshed, S.; Heijenk, Geert

    2015-01-01

    Energy-efficiency is an important requirement in the design of communication protocols for wireless sensor networks (WSN). TR-MAC is an energy-efficient medium access control (MAC) layer protocol for low power WSN that exploits transmitted-reference (TR) modulation in the physical layer. The

  5. Secure Protocol and IP Core for Configuration of Networking Hardware IPs in the Smart Grid

    Directory of Open Access Journals (Sweden)

    Marcelo Urbina

    2018-02-01

    Full Text Available Nowadays, the incorporation and constant evolution of communication networks in the electricity sector have given rise to the so-called Smart Grid, which is why it is necessary to have devices that are capable of managing new communication protocols, guaranteeing the strict requirements of processing required by the electricity sector. In this context, intelligent electronic devices (IEDs with network architectures are currently available to meet the communication, real-time processing and interoperability requirements of the Smart Grid. The new generation IEDs include an Field Programmable Gate Array (FPGA, to support specialized networking switching architectures for the electric sector, as the IEEE 1588-aware High-availability Seamless Redundancy/Parallel Redundancy Protocol (HSR/PRP. Another advantage to using an FPGA is the ability to update or reconfigure the design to support new requirements that are being raised to the standards (IEC 61850. The update of the architecture implemented in the FPGA can be done remotely, but it is necessary to establish a cyber security mechanism since the communication link generates vulnerability in the case the attacker gains physical access to the network. The research presented in this paper proposes a secure protocol and Intellectual Property (IP core for configuring and monitoring the networking IPs implemented in a Field Programmable Gate Array (FPGA. The FPGA based implementation proposed overcomes this issue using a light Layer-2 protocol fully implemented on hardware and protected by strong cryptographic algorithms (AES-GCM, defined in the IEC 61850-90-5 standard. The proposed secure protocol and IP core are applicable in any field where remote configuration over Ethernet is required for IP cores in FPGAs. In this paper, the proposal is validated in communications hardware for Smart Grids.

  6. Layered materials

    Science.gov (United States)

    Johnson, David; Clarke, Simon; Wiley, John; Koumoto, Kunihito

    2014-06-01

    Layered compounds, materials with a large anisotropy to their bonding, electrical and/or magnetic properties, have been important in the development of solid state chemistry, physics and engineering applications. Layered materials were the initial test bed where chemists developed intercalation chemistry that evolved into the field of topochemical reactions where researchers are able to perform sequential steps to arrive at kinetically stable products that cannot be directly prepared by other approaches. Physicists have used layered compounds to discover and understand novel phenomena made more apparent through reduced dimensionality. The discovery of charge and spin density waves and more recently the remarkable discovery in condensed matter physics of the two-dimensional topological insulating state were discovered in two-dimensional materials. The understanding developed in two-dimensional materials enabled subsequent extension of these and other phenomena into three-dimensional materials. Layered compounds have also been used in many technologies as engineers and scientists used their unique properties to solve challenging technical problems (low temperature ion conduction for batteries, easy shear planes for lubrication in vacuum, edge decorated catalyst sites for catalytic removal of sulfur from oil, etc). The articles that are published in this issue provide an excellent overview of the spectrum of activities that are being pursued, as well as an introduction to some of the most established achievements in the field. Clusters of papers discussing thermoelectric properties, electronic structure and transport properties, growth of single two-dimensional layers, intercalation and more extensive topochemical reactions and the interleaving of two structures to form new materials highlight the breadth of current research in this area. These papers will hopefully serve as a useful guideline for the interested reader to different important aspects in this field and

  7. Technical Analysis of SSP-21 Protocol

    Energy Technology Data Exchange (ETDEWEB)

    Bromberger, S. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States)

    2017-06-09

    As part of the California Energy Systems for the Twenty-First Century (CES-21) program, in December 2016 San Diego Gas and Electric (SDG&E) contracted with Lawrence Livermore National Laboratory (LLNL) to perform an independent verification and validation (IV&V) of a white paper describing their Secure SCADA Protocol for the Twenty-First Century (SSP-21) in order to analyze the effectiveness and propriety of cryptographic protocol use within the SSP-21 specification. SSP-21 is designed to use cryptographic protocols to provide (optional) encryption, authentication, and nonrepudiation, among other capabilities. The cryptographic protocols to be used reflect current industry standards; future versions of SSP-21 will use other advanced technologies to provide a subset of security services.

  8. Using the ACR/NEMA standard with TCP/IP and Ethernet

    Science.gov (United States)

    Chimiak, William J.; Williams, Rodney C.

    1991-07-01

    There is a need for a consolidated picture archival and communications system (PACS) in hospitals. At the Bowman Gray School of Medicine of Wake Forest University (BGSM), the authors are enhancing the ACR/NEMA Version 2 protocol using UNIX sockets and TCP/IP to greatly improve connectivity. Initially, nuclear medicine studies using gamma cameras are to be sent to PACS. The ACR/NEMA Version 2 protocol provides the functionality of the upper three layers of the open system interconnection (OSI) model in this implementation. The images, imaging equipment information, and patient information are then sent in ACR/NEMA format to a software socket. From there it is handed to the TCP/IP protocol, which provides the transport and network service. TCP/IP, in turn, uses the services of IEEE 802.3 (Ethernet) to complete the connectivity. The advantage of this implementation is threefold: (1) Only one I/O port is consumed by numerous nuclear medicine cameras, instead of a physical port for each camera. (2) Standard protocols are used which maximize interoperability with ACR/NEMA compliant PACSs. (3) The use of sockets allows a migration path to the transport and networking services of OSIs TP4 and connectionless network service as well as the high-performance protocol being considered by the American National Standards Institute (ANSI) and the International Standards Organization (ISO) -- the Xpress Transfer Protocol (XTP). The use of sockets also gives access to ANSI's Fiber Distributed Data Interface (FDDI) as well as other high-speed network standards.

  9. Denial of Service Attacks on 802.1X Security Protocol

    National Research Council Canada - National Science Library

    Ozan, Orhan

    2004-01-01

    ... infrastructure, such as military and administrative government LANs. The IEEE 802.11 wireless standard specifies both an authentication service and encryption protocol, but research has demonstrated that these protocols are severely flawed...

  10. Network protocols and sockets

    OpenAIRE

    BALEJ, Marek

    2010-01-01

    My work will deal with network protocols and sockets and their use in programming language C#. It will therefore deal programming network applications on the platform .NET from Microsoft and instruments, which C# provides to us. There will describe the tools and methods for programming network applications, and shows a description and sample applications that work with sockets and application protocols.

  11. A robust ECC based mutual authentication protocol with anonymity for session initiation protocol.

    Science.gov (United States)

    Mehmood, Zahid; Chen, Gongliang; Li, Jianhua; Li, Linsen; Alzahrani, Bander

    2017-01-01

    Over the past few years, Session Initiation Protocol (SIP) is found as a substantial application-layer protocol for the multimedia services. It is extensively used for managing, altering, terminating and distributing the multimedia sessions. Authentication plays a pivotal role in SIP environment. Currently, Lu et al. presented an authentication protocol for SIP and profess that newly proposed protocol is protected against all the familiar attacks. However, the detailed analysis describes that the Lu et al.'s protocol is exposed against server masquerading attack and user's masquerading attack. Moreover, it also fails to protect the user's identity as well as it possesses incorrect login and authentication phase. In order to establish a suitable and efficient protocol, having ability to overcome all these discrepancies, a robust ECC-based novel mutual authentication mechanism with anonymity for SIP is presented in this manuscript. The improved protocol contains an explicit parameter for user to cope the issues of security and correctness and is found to be more secure and relatively effective to protect the user's privacy, user's masquerading and server masquerading as it is verified through the comprehensive formal and informal security analysis.

  12. A robust ECC based mutual authentication protocol with anonymity for session initiation protocol.

    Directory of Open Access Journals (Sweden)

    Zahid Mehmood

    Full Text Available Over the past few years, Session Initiation Protocol (SIP is found as a substantial application-layer protocol for the multimedia services. It is extensively used for managing, altering, terminating and distributing the multimedia sessions. Authentication plays a pivotal role in SIP environment. Currently, Lu et al. presented an authentication protocol for SIP and profess that newly proposed protocol is protected against all the familiar attacks. However, the detailed analysis describes that the Lu et al.'s protocol is exposed against server masquerading attack and user's masquerading attack. Moreover, it also fails to protect the user's identity as well as it possesses incorrect login and authentication phase. In order to establish a suitable and efficient protocol, having ability to overcome all these discrepancies, a robust ECC-based novel mutual authentication mechanism with anonymity for SIP is presented in this manuscript. The improved protocol contains an explicit parameter for user to cope the issues of security and correctness and is found to be more secure and relatively effective to protect the user's privacy, user's masquerading and server masquerading as it is verified through the comprehensive formal and informal security analysis.

  13. Computer Program Re-layers Engineering Drawings

    Science.gov (United States)

    Crosby, Dewey C., III

    1990-01-01

    RULCHK computer program aids in structuring layers of information pertaining to part or assembly designed with software described in article "Software for Drawing Design Details Concurrently" (MFS-28444). Checks and optionally updates structure of layers for part. Enables designer to construct model and annotate its documentation without burden of manually layering part to conform to standards at design time.

  14. Estimation of the Thurstonian model for the 2-AC protocol

    DEFF Research Database (Denmark)

    Christensen, Rune Haubo Bojesen; Lee, Hye-Seong; Brockhoff, Per B.

    2012-01-01

    . This relationship makes it possible to extract estimates and standard errors of δ and τ from general statistical software, and furthermore, it makes it possible to combine standard regression modelling with the Thurstonian model for the 2-AC protocol. A model for replicated 2-AC data is proposed using cumulative......The 2-AC protocol is a 2-AFC protocol with a “no-difference” option and is technically identical to the paired preference test with a “no-preference” option. The Thurstonian model for the 2-AC protocol is parameterized by δ and a decision parameter τ, the estimates of which can be obtained...... by fairly simple well-known methods. In this paper we describe how standard errors of the parameters can be obtained and how exact power computations can be performed. We also show how the Thurstonian model for the 2-AC protocol is closely related to a statistical model known as a cumulative probit model...

  15. Design and standardization of PCR primers and protocols for detection of clonal immunoglobulin and T-cell receptor gene recombinations in suspect lymphoproliferations: Report of the BIOMED-2 Concerted Action BMH4-CT98-3936

    NARCIS (Netherlands)

    van Dongen, J. J. M.; Langerak, A. W.; Brüggemann, M.; Evans, P. A. S.; Hummel, M.; Lavender, F. L.; Delabesse, E.; Davi, F.; Schuuring, E.; García-Sanz, R.; van Krieken, J. H. J. M.; Droese, J.; González, D.; Bastard, C.; White, H. E.; Spaargaren, M.; González, M.; Parreira, A.; Smith, J. L.; Morgan, G. J.; Kneba, M.; Macintyre, E. A.

    2003-01-01

    In a European BIOMED-2 collaborative study, multiplex PCR assays have successfully been developed and standardized for the detection of clonally rearranged immunoglobulin (Ig) and T-cell receptor (TCR) genes and the chromosome aberrations t(11; 14) and t(14; 18). This has resulted in 107 different

  16. Design and standardization of PCR primers and protocols for detection of clonal immunoglobulin and T-cell receptor gene recombinations in suspect lymphoproliferations: report of the BIOMED-2 Concerted Action BMH4-CT98-3936.

    NARCIS (Netherlands)

    Dongen, J.J.M. van; Langerak, A.W.; Bruggemann, M.; Evans, P.; Hummel, M.; Lavender, F.L.; Delabesse, E.; Davi, F.; Schuuring, E.; Garcia-Sanz, R.; Krieken, J.H.J.M. van; Droese, J.; Gonzalez, D.; Bastard, C.; White, H.E.; Spaargaren, M.C.; Gonzalez, M.; Parreira, A.; Smith, J.L.; Morgan, G.J.; Kneba, M.; Macintyre, E.A.

    2003-01-01

    In a European BIOMED-2 collaborative study, multiplex PCR assays have successfully been developed and standardized for the detection of clonally rearranged immunoglobulin (Ig) and T-cell receptor (TCR) genes and the chromosome aberrations t(11;14) and t(14;18). This has resulted in 107 different

  17. A standardized crisis management model for self-harming and suicidal individuals with three or more diagnostic criteria of borderline personality disorder: The Brief Admission Skane randomized controlled trial protocol (BASRCT)

    NARCIS (Netherlands)

    Liljedahl, S.I.; Helleman, M.; Daukantaite, D.; Westrin, A.; Westling, S.

    2017-01-01

    BACKGROUND: Brief Admission is a crisis and risk management strategy in which self-harming and suicidal individuals with three or more diagnostic criteria of borderline personality disorder self-admit to hospital at times of increasing risk when other efforts to stay safe are failing. Standardized

  18. A new primary dental care service compared with standard care for child and family to reduce the re-occurrence of childhood dental caries (Dental RECUR): study protocol for a randomised controlled trial.

    Science.gov (United States)

    Pine, Cynthia; Adair, Pauline; Burnside, Girvan; Robinson, Louise; Edwards, Rhiannon Tudor; Albadri, Sondos; Curnow, Morag; Ghahreman, Marjan; Henderson, Mary; Malies, Clare; Wong, Ferranti; Muirhead, Vanessa; Weston-Price, Sally; Whitehead, Hilary

    2015-11-04

    also added to the challenges in implementing the Dental RECUR protocol during the recruitment phase. ISRCTN24958829 (date of registration: 27 September 2013), Current protocol version: 5.0.

  19. Intravenous iron isomaltoside 1000 administered by high single-dose infusions or standard medical care for the treatment of fatigue in women after postpartum haemorrhage: study protocol for a randomised controlled trial.

    Science.gov (United States)

    Holm, Charlotte; Thomsen, Lars Lykke; Norgaard, Astrid; Langhoff-Roos, Jens

    2015-01-14

    Postpartum haemorrhage can lead to iron deficiency with and without anaemia, the clinical consequences of which include physical fatigue. Although oral iron is the standard treatment, it is often associated with gastrointestinal side effects and poor compliance. To date, no published randomised controlled studies have compared the clinical efficacy and safety of standard medical care with intravenous administration of iron supplementation after postpartum haemorrhage.The primary objective of this study is to compare the efficacy of an intravenous high single-dose of iron isomaltoside 1000 with standard medical care on physical fatigue in women with postpartum haemorrhage. In a single centre, open-labelled, randomised trial, women with postpartum haemorrhage exceeding 700 mL will be allocated to either a single dose of 1,200 mg of iron isomaltoside 1000 or standard medical care. Healthy parturients with a singleton pregnancy will be included within 48 hours after delivery.Participants will complete structured questionnaires that focus on several dimensions of fatigue and mental health (Multidimensional Fatigue Inventory, Edinburgh Postnatal Depression Scale and the Postpartum Questionnaire), at inclusion and at follow-up visits after three days, one week, three weeks, eight weeks, and 12 weeks postpartum. The primary endpoint is the aggregated change in physical fatigue score within 12 weeks postpartum, as measured by a subscale of the Multidimensional Fatigue Inventory. The primary objective will be considered to have been met if an intravenous high single dose of iron isomaltoside 1000 is shown to be superior to standard medical care in women after postpartum haemorrhage regarding physical fatigue.For claiming superiority, we set the minimal clinically relevant difference between the mean scores at 1.8, and the assumed standard deviation at 4.2. Hence, 87 participants per treatment group are needed in order to demonstrate superiority; to provide an extra margin

  20. Samples and Sampling Protocols for Scientific Investigations | Joel ...

    African Journals Online (AJOL)

    ... from sampling, through sample preparation, calibration to final measurement and reporting. This paper, therefore offers useful information on practical guidance on sampling protocols in line with best practice and international standards. Keywords: Sampling, sampling protocols, chain of custody, analysis, documentation ...

  1. Analysing Password Protocol Security Against Off-line Dictionary Attacks

    NARCIS (Netherlands)

    Corin, R.J.; Doumen, J.M.; Etalle, Sandro; Busi, Nadia; Gorrieri, Roberto; Martinelli, Fabio

    We study the security of password protocols against off-line dictionary attacks. In addition to the standard adversary abilities, we also consider further cryptographic advantages given to the adversary when considering the password protocol being instantiated with particular encryption schemes. We

  2. Coded Splitting Tree Protocols

    DEFF Research Database (Denmark)

    Sørensen, Jesper Hemming; Stefanovic, Cedomir; Popovski, Petar

    2013-01-01

    This paper presents a novel approach to multiple access control called coded splitting tree protocol. The approach builds on the known tree splitting protocols, code structure and successive interference cancellation (SIC). Several instances of the tree splitting protocol are initiated, each...... instance is terminated prematurely and subsequently iterated. The combined set of leaves from all the tree instances can then be viewed as a graph code, which is decodable using belief propagation. The main design problem is determining the order of splitting, which enables successful decoding as early...

  3. Playing With Population Protocols

    Directory of Open Access Journals (Sweden)

    Xavier Koegler

    2009-06-01

    Full Text Available Population protocols have been introduced as a model of sensor networks consisting of very limited mobile agents with no control over their own movement: A collection of anonymous agents, modeled by finite automata, interact in pairs according to some rules. Predicates on the initial configurations that can be computed by such protocols have been characterized under several hypotheses. We discuss here whether and when the rules of interactions between agents can be seen as a game from game theory. We do so by discussing several basic protocols.

  4. MITRE sensor layer prototype

    Science.gov (United States)

    Duff, Francis; McGarry, Donald; Zasada, David; Foote, Scott

    2009-05-01

    The MITRE Sensor Layer Prototype is an initial design effort to enable every sensor to help create new capabilities through collaborative data sharing. By making both upstream (raw) and downstream (processed) sensor data visible, users can access the specific level, type, and quantities of data needed to create new data products that were never anticipated by the original designers of the individual sensors. The major characteristic that sets sensor data services apart from typical enterprise services is the volume (on the order of multiple terabytes) of raw data that can be generated by most sensors. Traditional tightly coupled processing approaches extract pre-determined information from the incoming raw sensor data, format it, and send it to predetermined users. The community is rapidly reaching the conclusion that tightly coupled sensor processing loses too much potentially critical information.1 Hence upstream (raw and partially processed) data must be extracted, rapidly archived, and advertised to the enterprise for unanticipated uses. The authors believe layered sensing net-centric integration can be achieved through a standardize-encapsulate-syndicateaggregate- manipulate-process paradigm. The Sensor Layer Prototype's technical approach focuses on implementing this proof of concept framework to make sensor data visible, accessible and useful to the enterprise. To achieve this, a "raw" data tap between physical transducers associated with sensor arrays and the embedded sensor signal processing hardware and software has been exploited. Second, we encapsulate and expose both raw and partially processed data to the enterprise within the context of a service-oriented architecture. Third, we advertise the presence of multiple types, and multiple layers of data through geographic-enabled Really Simple Syndication (GeoRSS) services. These GeoRSS feeds are aggregated, manipulated, and filtered by a feed aggregator. After filtering these feeds to bring just the type

  5. Mobile Internet Protocol Analysis

    National Research Council Canada - National Science Library

    Brachfeld, Lawrence

    1999-01-01

    ...) and User Datagram Protocol (UDP). Mobile IP allows mobile computers to send and receive packets addressed with their home network IP address, regardless of the IP address of their current point of attachment on the Internet...

  6. Transdiagnostic group CBT vs. standard group CBT for depression, social anxiety disorder and agoraphobia/panic disorder: Study protocol for a pragmatic, multicenter non-inferiority randomized controlled trial.

    Science.gov (United States)

    Arnfred, Sidse M; Aharoni, Ruth; Hvenegaard, Morten; Poulsen, Stig; Bach, Bo; Arendt, Mikkel; Rosenberg, Nicole K; Reinholt, Nina

    2017-01-23

    Transdiagnostic Cognitive Behavior Therapy (TCBT) manuals delivered in individual format have been reported to be just as effective as traditional diagnosis specific CBT manuals. We have translated and modified the "The Unified Protocol for Transdiagnostic Treatment of Emotional Disorders" (UP-CBT) for group delivery in Mental Health Service (MHS), and shown effects comparable to traditional CBT in a naturalistic study. As the use of one manual instead of several diagnosis-specific manuals could simplify logistics, reduce waiting time, and increase therapist expertise compared to diagnosis specific CBT, we aim to test the relative efficacy of group UP-CBT and diagnosis specific group CBT. The study is a partially blinded, pragmatic, non-inferiority, parallel, multi-center randomized controlled trial (RCT) of UP-CBT vs diagnosis specific CBT for Unipolar Depression, Social Anxiety Disorder and Agoraphobia/Panic Disorder. In total, 248 patients are recruited from three regional MHS centers across Denmark and included in two intervention arms. The primary outcome is patient-ratings of well-being (WHO Well-being Index, WHO-5), secondary outcomes include level of depressive and anxious symptoms, personality variables, emotion regulation, reflective functioning, and social adjustment. Assessments are conducted before and after therapy and at 6 months follow-up. Weekly patient-rated outcomes and group evaluations are collected for every session. Outcome assessors, blind to treatment allocation, will perform the observer-based symptom ratings, and fidelity assessors will monitor manual adherence. The current study will be the first RCT investigating the dissemination of the UP in a MHS setting, the UP delivered in groups, and with depressive patients included. Hence the results are expected to add substantially to the evidence base for rational group psychotherapy in MHS. The planned moderator and mediator analyses could spur new hypotheses about mechanisms of change in

  7. USA-USSR protocol

    CERN Multimedia

    1970-01-01

    On 30 November the USA Atomic Energy Commission and the USSR State Committee for the Utilization of Atomic Energy signed, in Washington, a protocol 'on carrying out of joint projects in the field of high energy physics at the accelerators of the National Accelerator Laboratory (Batavia) and the Institute for High Energy Physics (Serpukhov)'. The protocol will be in force for five years and can be extended by mutual agreement.

  8. An Enhanced LoRaWAN Security Protocol for Privacy Preservation in IoT with a Case Study on a Smart Factory-Enabled Parking System.

    Science.gov (United States)

    You, Ilsun; Kwon, Soonhyun; Choudhary, Gaurav; Sharma, Vishal; Seo, Jung Taek

    2018-06-08

    The Internet of Things (IoT) utilizes algorithms to facilitate intelligent applications across cities in the form of smart-urban projects. As the majority of devices in IoT are battery operated, their applications should be facilitated with a low-power communication setup. Such facility is possible through the Low-Power Wide-Area Network (LPWAN), but at a constrained bit rate. For long-range communication over LPWAN, several approaches and protocols are adopted. One such protocol is the Long-Range Wide Area Network (LoRaWAN), which is a media access layer protocol for long-range communication between the devices and the application servers via LPWAN gateways. However, LoRaWAN comes with fewer security features as a much-secured protocol consumes more battery because of the exorbitant computational overheads. The standard protocol fails to support end-to-end security and perfect forward secrecy while being vulnerable to the replay attack that makes LoRaWAN limited in supporting applications where security (especially end-to-end security) is important. Motivated by this, an enhanced LoRaWAN security protocol is proposed, which not only provides the basic functions of connectivity between the application server and the end device, but additionally averts these listed security issues. The proposed protocol is developed with two options, the Default Option (DO) and the Security-Enhanced Option (SEO). The protocol is validated through Burrows⁻Abadi⁻Needham (BAN) logic and the Automated Validation of Internet Security Protocols and Applications (AVISPA) tool. The proposed protocol is also analyzed for overheads through system-based and low-power device-based evaluations. Further, a case study on a smart factory-enabled parking system is considered for its practical application. The results, in terms of network latency with reliability fitting and signaling overheads, show paramount improvements and better performance for the proposed protocol compared with the two

  9. An Enhanced LoRaWAN Security Protocol for Privacy Preservation in IoT with a Case Study on a Smart Factory-Enabled Parking System

    Directory of Open Access Journals (Sweden)

    Ilsun You

    2018-06-01

    Full Text Available The Internet of Things (IoT utilizes algorithms to facilitate intelligent applications across cities in the form of smart-urban projects. As the majority of devices in IoT are battery operated, their applications should be facilitated with a low-power communication setup. Such facility is possible through the Low-Power Wide-Area Network (LPWAN, but at a constrained bit rate. For long-range communication over LPWAN, several approaches and protocols are adopted. One such protocol is the Long-Range Wide Area Network (LoRaWAN, which is a media access layer protocol for long-range communication between the devices and the application servers via LPWAN gateways. However, LoRaWAN comes with fewer security features as a much-secured protocol consumes more battery because of the exorbitant computational overheads. The standard protocol fails to support end-to-end security and perfect forward secrecy while being vulnerable to the replay attack that makes LoRaWAN limited in supporting applications where security (especially end-to-end security is important. Motivated by this, an enhanced LoRaWAN security protocol is proposed, which not only provides the basic functions of connectivity between the application server and the end device, but additionally averts these listed security issues. The proposed protocol is developed with two options, the Default Option (DO and the Security-Enhanced Option (SEO. The protocol is validated through Burrows–Abadi–Needham (BAN logic and the Automated Validation of Internet Security Protocols and Applications (AVISPA tool. The proposed protocol is also analyzed for overheads through system-based and low-power device-based evaluations. Further, a case study on a smart factory-enabled parking system is considered for its practical application. The results, in terms of network latency with reliability fitting and signaling overheads, show paramount improvements and better performance for the proposed protocol compared with

  10. Cluster Based Hierarchical Routing Protocol for Wireless Sensor Network

    OpenAIRE

    Rashed, Md. Golam; Kabir, M. Hasnat; Rahim, Muhammad Sajjadur; Ullah, Shaikh Enayet

    2012-01-01

    The efficient use of energy source in a sensor node is most desirable criteria for prolong the life time of wireless sensor network. In this paper, we propose a two layer hierarchical routing protocol called Cluster Based Hierarchical Routing Protocol (CBHRP). We introduce a new concept called head-set, consists of one active cluster head and some other associate cluster heads within a cluster. The head-set members are responsible for control and management of the network. Results show that t...

  11. Concurrent support of higher-layer protocols over WDM

    NARCIS (Netherlands)

    Theelen, B.D.; Voeten, J.P.M.; Putten, van der P.H.A.; Stevens, M.P.J.; Dorren, H.J.S.

    2002-01-01

    To satisfy the severe requirements involved in future communication networks, commercial and research interest in the applicability of wavelength division multiplexing (WDM) is growing. However, since WDM is merely concerned with transmitting bits over optical fibers, full advantage can only be

  12. a transport layer protocol using adaptive loss recovery method for ...

    Indian Academy of Sciences (India)

    Ayhan Kİraz

    Recently, critical projects were developed using wireless sensor network (WSN) such as medical and military ... provide high reliability, low power consumption, low end- to-end ... transmission and lower end-to-end packet latency values.

  13. Variability in donation after cardiac death protocols: a national survey.

    Science.gov (United States)

    Fugate, Jennifer E; Stadtler, Maria; Rabinstein, Alejandro A; Wijdicks, Eelco F M

    2011-02-27

    As donation after cardiac death practices expand, the number of institutional policies is increasing. We contacted organ procurement organizations throughout the United States and requested protocols in hospitals in their donor service areas. Sixty-four protocols were obtained with representation from 16 different states. The terminology and recommended practices varied substantially. The methods for death determination were not specified in 28 (44%) protocols. Most adhered to a 2- to 5-min observation time between circulatory arrest and organ procurement, but 10 (16%) provided no information. This variability reveals a need to define a uniform standard in donation after cardiac death protocols and death determination practices.

  14. A cluster randomized trial of standard quality improvement versus patient-centered interventions to enhance depression care for African Americans in the primary care setting: study protocol NCT00243425

    Directory of Open Access Journals (Sweden)

    Ghods Bri K

    2010-02-01

    Full Text Available Abstract Background Several studies document disparities in access to care and quality of care for depression for African Americans. Research suggests that patient attitudes and clinician communication behaviors may contribute to these disparities. Evidence links patient-centered care to improvements in mental health outcomes; therefore, quality improvement interventions that enhance this dimension of care are promising strategies to improve treatment and outcomes of depression among African Americans. This paper describes the design of the BRIDGE (Blacks Receiving Interventions for Depression and Gaining Empowerment Study. The goal of the study is to compare the effectiveness of two interventions for African-American patients with depression--a standard quality improvement program and a patient-centered quality improvement program. The main hypothesis is that patients in the patient-centered group will have a greater reduction in their depression symptoms, higher rates of depression remission, and greater improvements in mental health functioning at six, twelve, and eighteen months than patients in the standard group. The study also examines patient ratings of care and receipt of guideline-concordant treatment for depression. Methods/Design A total of 36 primary care clinicians and 132 of their African-American patients with major depressive disorder were recruited into a cluster randomized trial. The study uses intent-to-treat analyses to compare the effectiveness of standard quality improvement interventions (academic detailing about depression guidelines for clinicians and disease-oriented care management for their patients and patient-centered quality improvement interventions (communication skills training to enhance participatory decision-making for clinicians and care management focused on explanatory models, socio-cultural barriers, and treatment preferences for their patients for improving outcomes over 12 months of follow

  15. Effects of unconsciousness during spinal immobilization on tissue-interface pressures: A randomized controlled trial comparing a standard rigid spineboard with a newly developed soft-layered long spineboard.

    Science.gov (United States)

    Hemmes, Baukje; Brink, Peter R G; Poeze, Martijn

    2014-11-01

    Immobilization of the spine of patients with trauma at risk of spinal damage is usually performed using a rigid long spineboard or vacuum mattress, both during prehospital and in-hospital care. However, disadvantages of these immobilization devices in terms of discomfort and tissue-interface pressures have guided the development of soft-layered long spineboards. We compared tissue-interface pressures between awake and anaesthetized (unconscious) patients during immobilization on a rigid spineboard and a soft-layered long spineboard. In this comparative study, 30 anaesthetized patients were randomized to immobilization on either the rigid spineboard or the soft-layered spineboard for the duration of their elective surgery. Tissue-interface pressures measured using an Xsensor pressure-mapping device were compared with those of 30 healthy volunteers who were immobilized sequentially on the rigid spineboard and the soft-layered spineboard. Redness of the sacrum was also recorded for the anaesthetized patients immediately after the surgery. For both anaesthetized patients and awake volunteers, tissue-interface pressures were significantly lower on the soft-layered spineboard than on the rigid spineboard, both at start and after 15min. On the soft-layered spineboard, tissue interface pressure and peak pressure index (PPI) for the sacrum were significantly lower for anaesthetized patients than for awake volunteers. Peak pressures and PPI on the rigid spineboard were equal for both groups. Tissue-interface pressures did not change significantly over time. Redness of the sacrum was significantly more pronounced on the rigid spineboard than on the soft-layered spineboard. This prospective randomized controlled trial shows that using a soft-layered spineboard compared to a rigid spineboard for spinal immobilization resulted in lower tissue-interface pressures in both awake volunteers and anaesthetized patients. Moreover, tissue-interface pressures on the soft-layered

  16. Gravitational double layers

    International Nuclear Information System (INIS)

    Senovilla, José M M

    2014-01-01

    I analyze the properties of thin shells through which the scalar curvature R is discontinuous in gravity theories with Lagrangian F(R) = R − 2Λ + αR 2 on the bulk. These shells/domain walls are of a new kind because they possess, in addition to the standard energy–momentum tensor, an external energy flux vector, an external scalar pressure/tension and, most exotic of all, another energy–momentum contribution resembling classical dipole distributions on a shell: a double layer. I prove that all these contributions are necessary to make the entire energy–momentum tensor divergence-free. This is the first known occurrence of such a type of double layer in a gravity theory. I present explicit examples in constant-curvature five-dimensional bulks, with a brief study of their properties: new physical behaviors arise. (fast track communications)

  17. Power Saving MAC Protocols for WSNs and Optimization of S-MAC Protocol

    Directory of Open Access Journals (Sweden)

    Simarpreet Kaur

    2012-11-01

    Full Text Available Low power MAC protocols have received a lot of consideration in the last few years because of their influence on the lifetime of wireless sensor networks. Since, sensors typically operate on batteries, replacement of which is often difficult. A lot of work has been done to minimize the energy expenditure and prolong the sensor lifetime through energy efficient designs, across layers. Meanwhile, the sensor network should be able to maintain a certain throughput in order to fulfill the QoS requirements of the end user, and to ensure the constancy of the network. This paper introduces different types of MAC protocols used for WSNs and proposes S‐MAC, a Medium‐Access Control protocol designed for Wireless Sensor Networks. S‐MAC uses a few innovative techniques to reduce energy consumption and support selfconfiguration. A new protocol is suggested to improve the energy efficiency, latency and throughput of existing MAC protocol for WSNs. A modification of the protocol is then proposed to eliminate the need for some nodes to stay awake longer than the other nodes which improves the energy efficiency, latency and throughput and hence increases the life span of a wireless sensor network.

  18. The impact of a knowledge translation intervention employing educational outreach and a point-of-care reminder tool vs standard lay health worker training on tuberculosis treatment completion rates: study protocol for a cluster randomized controlled trial.

    Science.gov (United States)

    Puchalski Ritchie, Lisa M; van Lettow, Monique; Makwakwa, Austine; Chan, Adrienne K; Hamid, Jemila S; Kawonga, Harry; Martiniuk, Alexandra L C; Schull, Michael J; van Schoor, Vanessa; Zwarenstein, Merrick; Barnsley, Jan; Straus, Sharon E

    2016-09-07

    periods, for a total of 40-60 interview participants. This study will directly inform the efforts of knowledge users within TB care and, through extension of the approach, other areas of care provided by LHWs in Malawi and other low- and middle-income countries. ClinicalTrials.gov NCT02533089 . Registered 20 August 2015. Protocol Date/Version 29 May 2016/Version 2.

  19. Uniform measurement standard for heat supply in housing and utility building construction. A protocol to compare alternatives for heat supply at building construction sites. Version 3.1; Uniforme Maatlat voor de warmtevoorziening in de woning- en utiliteitsbouw. Een protocol voor het vergelijken van alternatieven voor de warmtevoorziening op bouwlocaties. Versie 3.1

    Energy Technology Data Exchange (ETDEWEB)

    Nuiten, P. [W/E adviseurs, Utrecht (Netherlands); Van der Ree, B. [Primum, Driebergen-Rijsenburg (Netherlands)

    2012-02-15

    The uniform measurement standard is one of the methods that the National Expertise Heat Centre develops to compare the energy efficiency of different techniques (such as heat pumps, heat and cold storage, collective systems, waste heat, combustion of woody biomass, etc.). The development of the uniform standard was started for the residential and utility building construction industry. In the future, the standard calculation method will also be made available for other sectors [Dutch] De uniforme maatlat is 1 van de methoden die het Nationaal Expertisecentrum Warmte ontwikkelt om de energieprestaties van verschillende technieken (zoals warmtepompen, warmte-koudeopslag, collectieve systemen, restwarmte, verbranding van houtachtige biomassa, etc.) goed vergelijkbaar te maken. De ontwikkeling van de uniforme maatlat is gestart voor de woning- en utiliteitsbouw. In de toekomst zal de uniforme maatlat ook voor andere sectoren beschikbaar komen. In deze versie van de uniforme maatlat is aansluiting gezocht bij de kengetallen van de Energieprestatienorm voor Maatregelen op Gebiedsniveau (EMG), zodat de resultaten van de uniforme maatlat in lijn zijn met die van de EMG.

  20. Assessing the efficacy of the healthy eating and lifestyle programme (HELP compared with enhanced standard care of the obese adolescent in the community: study protocol for a randomized controlled trial

    Directory of Open Access Journals (Sweden)

    Christie Deborah

    2011-11-01

    Full Text Available Abstract Background The childhood obesity epidemic is one of the foremost UK health priorities. Childhood obesity tracks into adult life and places individuals at considerable risk for diabetes, cardiovascular disease, liver disease and other morbidities. There is widespread need for paediatric lifestyle programmes as change may be easier to accomplish in childhood than later in life. Study Design/Method The study will evaluate the management of adolescent obesity by conducting a Medical Research Council complex intervention phase III efficacy randomised clinical trial of the Healthy Eating Lifestyle Programme within primary care. The study tests a community delivered multi-component intervention designed for adolescents developed from best practice as identified by National Institute for Health and Clinical Excellence. The hospital based pilot reduced body mass index and improved health-related quality of life. Subjects will be individually randomised to receiving either the Healthy Eating Lifestyle Programme (12 fortnightly family sessions or enhanced standard care. Baseline and follow up assessments will be undertaken blind to allocation status. A health economic evaluation is also being conducted. 200 obese young people (13-17 years, body mass index > 98th centile for age and sex will be recruited from primary care within the greater London area. The primary hypothesis is that a motivational and solution-focused family-based weight management programme delivered over 6 months is more efficacious in reducing body mass index in obese adolescents identified in the community than enhanced standard care. The primary outcome will be body mass index at the end of the intervention, adjusted for baseline body mass index, age and sex. The secondary hypothesis is that the Healthy Eating Lifestyle Programme is more efficacious in improving quality of life and psychological function and reducing waist circumference and cardiovascular risk factors in

  1. Vehicular Networks and Road Safety: an Application for Emergency/Danger Situations Management Using the WAVE/802.11p Standard

    Directory of Open Access Journals (Sweden)

    Peppino Fazio

    2013-01-01

    Full Text Available Car-to-car communication makes possible offering many services for vehicular environment, mainly to improve the safety. The decentralized kind of these networks requires new protocols to distribute information. The advantages that it offers depend on the penetration rate, that will be enough only after years since the introduction, due to the longevity of the current cars. The V2X communication requires On-Board Units (OBUs in the vehicles, and Road-Side Units (RSUs on the roads. The proposed application uses the peculiarities of the VANETs to advise danger or emergency situations with V2V and V2I message exchange. IEEE 802.11p is standard on which the communication is based, that provides the physical and the MAC layers. The WAVE protocol uses this standard, implementing other protocols defined by the family of standards IEEE P1609 in the upper layers. They define security services, resource management, multichannel operations and the message exchange protocol in WAVE. The performance of the application will be evaluated through many simulations executed in different scenarios, to provide general data independent from them.

  2. Protocol for an economic evaluation alongside the University Health Network Whiplash Intervention Trial: cost-effectiveness of education and activation, a rehabilitation program, and the legislated standard of care for acute whiplash injury in Ontario

    Science.gov (United States)

    2011-01-01

    Background Whiplash injury affects 83% of persons in a traffic collision and leads to whiplash-associated disorders (WAD). A major challenge facing health care decision makers is identifying cost-effective interventions due to lack of economic evidence. Our objective is to compare the cost-effectiveness of: 1) physician-based education and activation, 2) a rehabilitation program developed by Aviva Canada (a group of property and casualty insurance providers), and 3) the legislated standard of care in the Canadian province of Ontario: the Pre-approved Framework Guideline for Whiplash developed by the Financial Services Commission of Ontario. Methods/Design The economic evaluation will use participant-level data from the University Health Network Whiplash Intervention Trial and will be conducted from the societal perspective over the trial's one-year follow-up. Resource use (costs) will include all health care goods and services, and benefits provided during the trial's 1-year follow-up. The primary health effect will be the quality-adjusted life year. We will identify the most cost-effective intervention using the incremental cost-effectiveness ratio and incremental net-benefit. Confidence ellipses and cost-effectiveness acceptability curves will represent uncertainty around these statistics, respectively. A budget impact analysis will assess the total annual impact of replacing the current legislated standard of care with each of the other interventions. An expected value of perfect information will determine the maximum research expenditure Canadian society should be willing to pay for, and inform priority setting in, research of WAD management. Discussion Results will provide health care decision makers with much needed economic evidence on common interventions for acute whiplash management. Trial Registration http://ClinicalTrials.gov identifier NCT00546806 [Trial registry date: October 18, 2007; Date first patient was randomized: February 27, 2008] PMID

  3. Protocol for an economic evaluation alongside the University Health Network Whiplash Intervention Trial: cost-effectiveness of education and activation, a rehabilitation program, and the legislated standard of care for acute whiplash injury in Ontario

    Directory of Open Access Journals (Sweden)

    van der Velde Gabrielle

    2011-07-01

    Full Text Available Abstract Background Whiplash injury affects 83% of persons in a traffic collision and leads to whiplash-associated disorders (WAD. A major challenge facing health care decision makers is identifying cost-effective interventions due to lack of economic evidence. Our objective is to compare the cost-effectiveness of: 1 physician-based education and activation, 2 a rehabilitation program developed by Aviva Canada (a group of property and casualty insurance providers, and 3 the legislated standard of care in the Canadian province of Ontario: the Pre-approved Framework Guideline for Whiplash developed by the Financial Services Commission of Ontario. Methods/Design The economic evaluation will use participant-level data from the University Health Network Whiplash Intervention Trial and will be conducted from the societal perspective over the trial's one-year follow-up. Resource use (costs will include all health care goods and services, and benefits provided during the trial's 1-year follow-up. The primary health effect will be the quality-adjusted life year. We will identify the most cost-effective intervention using the incremental cost-effectiveness ratio and incremental net-benefit. Confidence ellipses and cost-effectiveness acceptability curves will represent uncertainty around these statistics, respectively. A budget impact analysis will assess the total annual impact of replacing the current legislated standard of care with each of the other interventions. An expected value of perfect information will determine the maximum research expenditure Canadian society should be willing to pay for, and inform priority setting in, research of WAD management. Discussion Results will provide health care decision makers with much needed economic evidence on common interventions for acute whiplash management. Trial Registration http://ClinicalTrials.gov identifier NCT00546806 [Trial registry date: October 18, 2007; Date first patient was randomized: February

  4. Multiprofissional electronic protocol in ophtalmology with enfasis in strabismus

    Directory of Open Access Journals (Sweden)

    CHRISTIE GRAF RIBEIRO

    Full Text Available ABSTRACT Objective: to create and validate an electronic database in ophthalmology focused on strabismus, to computerize this database in the form of a systematic data collection software named Electronic Protocol, and to incorporate this protocol into the Integrated System of Electronic Protocols (SINPE(c. Methods: this is a descriptive study, with the methodology divided into three phases: (1 development of a theoretical ophthalmologic database with emphasis on strabismus; (2 computerization of this theoretical ophthalmologic database using SINPE(c and (3 interpretation of the information with demonstration of results to validate the protocol. We inputed data from the charts of fifty patients with known strabismus through the Electronic Protocol for testing and validation. Results: the new electronic protocol was able to store information regarding patient history, physical examination, laboratory exams, imaging results, diagnosis and treatment of patients with ophthalmologic diseases, with emphasis on strabismus. We included 2,141 items in this master protocol and created 20 new specific electronic protocols for strabismus, each with its own specifics. Validation was achieved through correlation and corroboration of the symptoms and confirmed diagnoses of the fifty included patients with the diagnostic criteria for the twenty new strabismus protocols. Conclusion: a new, validated electronic database focusing on ophthalmology, with emphasis on strabismus, was successfully created through the standardized collection of information, and computerization of the database using proprietary software. This protocol is ready for deployment to facilitate data collection, sorting and application for practitioners and researchers in numerous specialties.

  5. Business protocol in integrated Europe

    OpenAIRE

    Pavelová, Nina

    2009-01-01

    The first chapter devotes to definitions of basic terms such as protocol or business protocol, to differences between protocol and etiquette, and between social etiquette and business etiquette. The second chapter focuses on the factors influencing the European business protocol. The third chapter is devoted to the etiquette of business protocol in the European countries. It touches the topics such as punctuality and planning of business appointment, greeting, business cards, dress and appear...

  6. Security Protocols in a Nutshell

    OpenAIRE

    Toorani, Mohsen

    2016-01-01

    Security protocols are building blocks in secure communications. They deploy some security mechanisms to provide certain security services. Security protocols are considered abstract when analyzed, but they can have extra vulnerabilities when implemented. This manuscript provides a holistic study on security protocols. It reviews foundations of security protocols, taxonomy of attacks on security protocols and their implementations, and different methods and models for security analysis of pro...

  7. A three-group study, internet-based, face-to-face based and standard- management after acute whiplash associated disorders (WAD – choosing the most efficient and cost-effective treatment: study protocol of a randomized controlled trial

    Directory of Open Access Journals (Sweden)

    Bring Annika

    2009-07-01

    Full Text Available Abstract Background The management of Whiplash Associated Disorders is one of the most complicated challenges with high expenses for the health care system and society. There are still no general guidelines or scientific documentation to unequivocally support any single treatment for acute care following whiplash injury. The main purpose of this study is to try a new behavioural medicine intervention strategy at acute phase aimed to reduce the number of patients who have persistent problems after the whiplash injury. The goal is also to identify which of three different interventions that is most cost-effective for patients with Whiplash Associated Disorders. In this study we are controlling for two factors. First, the effect of behavioural medicine approach is compared with standard care. Second, the manner in which the behavioural medicine treatment is administered, Internet or face-to-face, is evaluated in it's effectiveness and cost-effectiveness. Methods/Design The study is a randomized, prospective, experimental three-group study with analyses of cost-effectiveness up to two-years follow-up. Internet – based programme and face-to-face group treatment programme are compared to standard-treatment only. Patient follow-ups take place three, six, twelve and 24 months, that is, short-term as well as long-term effects are evaluated. Patients will be enrolled via the emergency ward during the first week after the accident. Discussion This new self-help management will concentrate to those psychosocial factors that are shown to be predictive in long-term problems in Whiplash Associated Disorders, i.e. the importance of self-efficacy, fear of movement, and the significance of catastrophizing as a coping strategy for restoring and sustaining activities of daily life. Within the framework of this project, we will develop, broaden and evaluate current physical therapy treatment methods for acute Whiplash Associated Disorders. The project will

  8. Intelligent Local Avoided Collision (iLAC) MAC Protocol for Very High Speed Wireless Network

    Science.gov (United States)

    Hieu, Dinh Chi; Masuda, Akeo; Rabarijaona, Verotiana Hanitriniala; Shimamoto, Shigeru

    Future wireless communication systems aim at very high data rates. As the medium access control (MAC) protocol plays the central role in determining the overall performance of the wireless system, designing a suitable MAC protocol is critical to fully exploit the benefit of high speed transmission that the physical layer (PHY) offers. In the latest 802.11n standard [2], the problem of long overhead has been addressed adequately but the issue of excessive colliding transmissions, especially in congested situation, remains untouched. The procedure of setting the backoff value is the heart of the 802.11 distributed coordination function (DCF) to avoid collision in which each station makes its own decision on how to avoid collision in the next transmission. However, collision avoidance is a problem that can not be solved by a single station. In this paper, we introduce a new MAC protocol called Intelligent Local Avoided Collision (iLAC) that redefines individual rationality in choosing the backoff counter value to avoid a colliding transmission. The distinguishing feature of iLAC is that it fundamentally changes this decision making process from collision avoidance to collaborative collision prevention. As a result, stations can avoid colliding transmissions with much greater precision. Analytical solution confirms the validity of this proposal and simulation results show that the proposed algorithm outperforms the conventional algorithms by a large margin.

  9. Evaluation of Protocol Uniformity Concerning Laparoscopic Cholecystectomy in The Netherlands

    Science.gov (United States)

    Goossens, Richard H. M.; van Eijk, Daan J.; Lange, Johan F.

    2008-01-01

    Background Iatrogenic bile duct injury remains a current complication of laparoscopic cholecystectomy. One uniform and standardized protocol, based on the “critical view of safety” concept of Strasberg, should reduce the incidence of this complication. Furthermore, owing to the rapid development of minimally invasive surgery, technicians are becoming more frequently involved. To improve communication between the operating team and technicians, standardized actions should also be defined. The aim of this study was to compare existing protocols for laparoscopic cholecystectomy from various Dutch hospitals. Methods Fifteen Dutch hospitals were contacted for evaluation of their protocols for laparoscopic cholecystectomy. All evaluated protocols were divided into six steps and were compared accordingly. Results In total, 13 hospitals responded—5 academic hospitals, 5 teaching hospitals, 3 community hospitals—of which 10 protocols were usable for comparison. Concerning the trocar positions, only minor differences were found. The concept of “critical view of safety” was represented in just one protocol. Furthermore, the order of clipping and cutting the cystic artery and duct differed. Descriptions of instruments and apparatus were also inconsistent. Conclusions Present protocols differ too much to define a universal procedure among surgeons in The Netherlands. The authors propose one (inter)national standardized protocol, including standardized actions. This uniform standardized protocol has to be officially released and recommended by national scientific associations (e.g., the Dutch Society of Surgery) or international societies (e.g., European Association for Endoscopic Surgery and Society of American Gastrointestinal and Endoscopic Surgeons). The aim is to improve patient safety and professional communication, which are necessary for new developments. PMID:18224485

  10. QUALITY OF LIFE AND COMPLIANCE TO THERAPY IN PATIENTS FOLLOWING SUCCESSFULTRANSLUMINAL CORONARY ANGIOPLASTY, WHO WERE PRESCRIBED FLUVASTATIN EXTENDED RELEASE ADDED TO STANDARD THERAPY. PROTOCOL OF THE OPEN-LABEL OBSERVATIONAL STUDY

    Directory of Open Access Journals (Sweden)

    A. V. Susekov

    2010-01-01

    Full Text Available Aim. To evaluate quality of life changes and compliance to therapy in patients following successful transluminal angioplasty, who have indications for fluvastatin extended release in addition to standard treatment.Material and methods. This is a national observational multicenter study. An inclusion of 60 investigator centers is planned (out-patient medical centers, the total number of patients to be included is 600. Patients (men and women with coronary heart disease following successful transluminal coronary angioplasty, who were prescribed fluvastatinextended release (Lescol Forte, Novartis 80 mg once daily will be included in the observation. The following efficacy and safety parameters will be evaluated: quality of life assessed with SF-36 scale before and during treatment; compliance to therapy; adverse events and serious adverse events. Observation period is planned for 6 months. During this period patient is expected to make 4 visits to treating physician. According to the physician’s decision, observation period can be extended to 12 months.Present study status. The study is completed. 524 patients completed the observation, including 116 patients who were followed up for 12 months. There are 414 men (79% and 110 women (21% among patients enrolled into the study.

  11. The DYD-RCT protocol: an on-line randomised controlled trial of an interactive computer-based intervention compared with a standard information website to reduce alcohol consumption among hazardous drinkers

    Directory of Open Access Journals (Sweden)

    Godfrey Christine

    2007-10-01

    Full Text Available Abstract Background Excessive alcohol consumption is a significant public health problem throughout the world. Although there are a range of effective interventions to help heavy drinkers reduce their alcohol consumption, these have little proven population-level impact. Researchers internationally are looking at the potential of Internet interventions in this area. Methods/Design In a two-arm randomised controlled trial, an on-line psychologically enhanced interactive computer-based intervention is compared with a flat, text-based information web-site. Recruitment, consent, randomisation and data collection are all on-line. The primary outcome is total past-week alcohol consumption; secondary outcomes include hazardous or harmful drinking, dependence, harm caused by alcohol, and mental health. A health economic analysis is included. Discussion This trial will provide information on the effectiveness and cost-effectiveness of an on-line intervention to help heavy drinkers drink less. Trial registration International Standard Randomised Controlled Trial Number Register ISRCTN31070347

  12. Report, realized on behalf of the foreign Affairs, the Defense and the Armed Forces Commission: - on the law project, carried by the Senate, authorizing the approval of the amendment for the 16 september 1987 Montreal protocol relative to the substances which impoverish the ozone layer, adopted at Montreal the 17 september 1997; - and on the law project, carried by the Senate, authorizing the approval of the amendment for the 16 september 1987 Montreal protocol relative to the substances which impoverish the ozone layer, adopted at Pekin the 3 december 1999

    Energy Technology Data Exchange (ETDEWEB)

    Guillet, J.J.

    2003-07-01

    The document presents the text of the law projects concerning the substances which impoverish the ozone layer. Facts of science,protection systems and the two amendments adopted at Montreal in 1997 and Pekin in 1999 are discussed. For each countries data on the substances impoverish the ozone layer, are also given. (A.L.B.)

  13. Miracle: The Multi-Interface Cross-Layer Extension of ns2

    Directory of Open Access Journals (Sweden)

    Guerra Federico

    2010-01-01

    Full Text Available We present Miracle, a novel framework which extends ns2 to facilitate the simulation and the design of beyond 4G networks. Miracle enhances ns2 by providing an efficient and embedded engine for handling cross-layer messages and, at the same time, enabling the coexistence of multiple modules within each layer of the protocol stack. We also present a novel framework developed as an extension of Miracle called Miracle PHY and MAC. This framework facilitates the development of more realistic Channel, PHY and MAC modules, considering features currently lacking in most state-of-the-art simulators, while at the same time giving a strong emphasis on code modularity, interoperability and reusability. Finally, we provide an overview of the wireless technologies implemented in Miracle, discussing in particular the models for the IEEE 802.11, UMTS and WiMAX standards and for Underwater Acoustic Networks. We observe that, thanks to Miracle and its extensions, it is possible to carefully simulate complex network architectures at all the OSI layers, from the physical reception model to standard applications and system management schemes. This allows to have a comprehensive view of all the interactions among network components, which play an important role in many research areas, such as cognitive networking and cross-layer design.

  14. Padronização de um protocolo experimental de treinamento periodizado em natação utilizando ratos Wistar Standardization of an experimental periodized training protocol in swimming rats

    Directory of Open Access Journals (Sweden)

    Gustavo Gomes de Araujo

    2010-02-01

    creatine kinase (CK in rats. Seventy male Wistar rats were randomly separated in two groups: Control Group (CG n = 30 and Training Periodization Group (TPG n = 30. All experiments were preceded by 2 weeks of individual adaptation to the water. The TPG was carried out during a period of 12 weeks (w with frequency of 6 days/w. The training period was subdivided in three specialized series blocks: Preparation (6 w, Specific (4.5 w and Taper (1.5 w. The Lactate Minimun Test (LACm was adapted to determine the aerobic capacity. Anaerobic performance was evaluated by maximal exhaustion time (Tlim verified during hyperlactatemia induction phase in the LACm protocol. Training stimulus was based on intensities corresponding to the LACm: Endurance (END 1 = 80%; END2= 100%; END3= 120% and Anaerobic (ANA 240% of the LACm. Two-way Anova and Newman-Keuls post-hoc test (P<0.05were also used. Aerobic performance was not different from initial training (Preparation: 4.57 ± 0.24% of body weigh (bw; Specific: 4.59 ± 0.44 %bw, but at the end of taper, the LACm was higher (Taper: 5.01 ± 0.71% bw. The anaerobic parameter (Tlim was significantly higher at the end of taper (73 ± 14s when compared to the Preparation (50 ± 13s and Specific blocks (65 ± 18s. The CG reduced the LACm and anaerobic performance along the experimental period. The glycogen M increased after taper but CK did not alter during training. Training periodization in rats acted as an important tool to evaluate specific effects of training. This is supported by sensitive responses of the rats along the blocks, based on improvement of aerobic and anaerobic performance as well as glycogen concentration obtained after the taper block.

  15. Analysing Protocol Stacks for Services

    DEFF Research Database (Denmark)

    Gao, Han; Nielson, Flemming; Nielson, Hanne Riis

    2011-01-01

    We show an approach, CaPiTo, to model service-oriented applications using process algebras such that, on the one hand, we can achieve a certain level of abstraction without being overwhelmed by the underlying implementation details and, on the other hand, we respect the concrete industrial...... standards used for implementing the service-oriented applications. By doing so, we will be able to not only reason about applications at different levels of abstractions, but also to build a bridge between the views of researchers on formal methods and developers in industry. We apply our approach...... to the financial case study taken from Chapter 0-3. Finally, we develop a static analysis to analyse the security properties as they emerge at the level of concrete industrial protocols....

  16. Communicating systems with UML 2 modeling and analysis of network protocols

    CERN Document Server

    Barrera, David Garduno

    2013-01-01

    This book gives a practical approach to modeling and analyzing communication protocols using UML 2. Network protocols are always presented with a point of view focusing on partial mechanisms and starting models. This book aims at giving the basis needed for anybody to model and validate their own protocols. It follows a practical approach and gives many examples for the description and analysis of well known basic network mechanisms for protocols.The book firstly shows how to describe and validate the main protocol issues (such as synchronization problems, client-server interactions, layer

  17. The depletion of the stratospheric ozone layer

    International Nuclear Information System (INIS)

    Sabogal Nelson

    2000-01-01

    The protection of the Earth's ozone layer is of the highest importance to mankind. The dangers of its destruction are by now well known. The depletion of that layer has reached record levels. The Antarctic ozone hole covered this year a record area. The ozone layer is predicted to begin recovery in the next one or two decades and should be restored to pre-1980 levels by 2050. This is the achievement of the regime established by the 1985 Vienna Convention for the Protection of the Ozone Layer and the 1987 Montreal Protocol on Substances that Deplete the Ozone Layer. The regime established by these two agreements has been revised, and made more effective in London (1990), Copenhagen (1992), Vienna (1995), and Beijing (1999)

  18. Nurse health and lifestyle modification versus standard care in 40 to 70 year old regional adults: study protocol of the Management to Optimise Diabetes and mEtabolic syndrome Risk reduction via Nurse-led intervention (MODERN) randomized controlled trial.

    Science.gov (United States)

    Carrington, Melinda J; Zimmet, Paul

    2017-12-06

    Metabolic syndrome (MetS), the clustering of multiple leading risk factors, predisposes individuals to increased risk for developing type 2 diabetes and/or cardiovascular disease (CVD). Cardio-metabolic disease risk increases with greater remoteness where specialist services are scarce. Nurse-led interventions are effective for the management of chronic disease. The aim of this clinical trial is to determine whether a nurse-implemented health and lifestyle modification program is more beneficial than standard care to reduce cardio-metabolic abnormalities and future risk of CVD and diabetes in individuals with MetS. MODERN is a multi-centre, open, parallel group randomized controlled trial in regional Victoria, Australia. Participants were self-selected and individuals aged 40 to 70 years with MetS who had no evidence of CVD or other chronic disease were recruited. Those attending a screening visit with any 3 or more risk factors of central obesity, dyslipidemia (high triglycerides or low high density lipoprotein cholesterol) elevated blood pressure and dysglycemia were randomized to either nurse-led health and lifestyle modification (intervention) or standard care (control). The intervention included risk factor management, health education, care planning and scheduled follow-up commensurate with level of risk. The primary cardio-metabolic end-point was achievement of risk factor thresholds to eliminate MetS or minimal clinically meaningful changes for at least 3 risk factors that characterise MetS over 2 year follow-up. Pre-specified secondary endpoints to evaluate between group variations in cardio-metabolic risk, general health and lifestyle behaviours and new onset CVD and type 2 diabetes will be evaluated. Key outcomes will be measured at baseline, 12 and 24 months via questionnaires, physical examinations, pathology and other diagnostic tests. Health economic analyses will be undertaken to establish the cost-effectiveness of the intervention. The MODERN

  19. Migration and head penetration of Vitamin-E diffused cemented polyethylene cup compared to standard cemented cup in total hip arthroplasty: study protocol for a randomised, double-blind, controlled trial (E1 HIP).

    Science.gov (United States)

    Sköldenberg, Olof; Rysinska, Agata; Chammout, Ghazi; Salemyr, Mats; Muren, Olle; Bodén, Henrik; Eisler, Thomas

    2016-07-07

    In vitro, Vitamin-E-diffused, highly cross-linked polyethylene (PE) has been shown to have superior wear resistance and improved mechanical properties when compared to those of standard highly cross-linked PE liners used in total hip arthroplasty (THA). The aim of the study is to evaluate the safety of a new cemented acetabular cup with Vitamin-E-doped PE regarding migration, head penetration and clinical results. In this single-centre, double-blinded, randomised controlled trial, we will include 50 patients with primary hip osteoarthritis scheduled for THA and randomise them in a 1:1 ratio to a cemented cup with either argon gas-sterilised PE (control group) or Vitamin-E-diffused PE (vitamin-e group). All patients and the assessor of the primary outcome will be blinded and the same uncemented stem will be used for all participants. The primary end point will be proximal migration of the cup at 2 years after surgery measured with radiostereometry. Secondary end points include proximal migration at other follow-ups, total migration, femoral head penetration, clinical outcome scores and hip-related complications. Patients will be followed up at 3 months and at 1, 2, 5 and 10 years postoperatively. Results will be analysed using 95% CIs for the effect size. A regression model will also be used to adjust for stratification factors. The ethical committee at Karolinska Institutet has approved the study. The first results from the study will be disseminated to the medical community via presentations and publications in relevant medical journals when the last patient included has been followed up for 2 years. NCT02254980. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/

  20. Evaluation of dose reduction versus standard dosing for maintenance of remission in patients with spondyloarthritis and clinical remission with anti-TNF (REDES-TNF): study protocol for a randomized controlled trial.

    Science.gov (United States)

    Pontes, Caridad; Gratacós, Jordi; Torres, Ferran; Avendaño, Cristina; Sanz, Jesús; Vallano, Antoni; Juanola, Xavier; de Miguel, Eugenio; Sanmartí, Raimon; Calvo, Gonzalo

    2015-08-20

    Dose reduction schedules of tumor necrosis factor antagonists (anti-TNF) as maintenance therapy in patients with spondyloarthritis are used empirically in clinical practice, despite the lack of clinical trials providing evidence for this practice. To address this issue the Spanish Society of Rheumatology (SER) and Spanish Society of Clinical Pharmacology (SEFC) designed a 3-year multicenter, randomized, open-label, controlled clinical trial (2 years for inclusion and 1 year of follow-up). The study is expected to include 190 patients with axial spondyloarthritis on stable maintenance treatment (≥4 months) with any anti-TNF agent at doses recommended in the summary of product characteristics. Patients will be randomized to either a dose reduction arm or maintenance of the dosing regimen as per the official labelling recommendations. Randomization will be stratified according to the anti-TNF agent received before study inclusion. Patient follow-up, visit schedule, and examinations will be maintained as per normal clinical practice recommendations according to SER guidelines. The study aims to test the hypothesis of noninferiority of the dose reduction strategy compared with standard treatment. The first patients were recruited in July 2012, and study completion is scheduled for the end of April 2015. The REDES-TNF study is a pragmatic clinical trial that aims to provide evidence to support a medical decision now made empirically. The study results may help inform clinical decisions relevant to both patients and healthcare decision makers. EudraCT 2011-005871-18 (21 December 2011).

  1. Tight intra-operative blood pressure control versus standard care for patients undergoing hip fracture repair - Hip Fracture Intervention Study for Prevention of Hypotension (HIP-HOP) trial: study protocol for a randomised controlled trial.

    Science.gov (United States)

    Moppett, Iain Keith; White, Stuart; Griffiths, Richard; Buggy, Donal

    2017-07-25

    Hypotension during anaesthesia for hip fracture surgery is common. Recent data suggest that there is an association between the lowest intra-operative blood pressure and mortality, even when adjusted for co-morbidities. This is consistent with data derived from the wider surgical population, where magnitude and duration of hypotension are associated with mortality and peri-operative complications. However, there are no trial to data to support more aggressive blood pressure control. We are conducting a three-centre, randomised, double-blinded pilot study in three hospitals in the United Kingdom. The sample size will be 75 patients (25 from each centre). Randomisation will be done using computer-generated concealed tables. Both participants and investigators will be blinded to group allocation. Participants will be aged >70 years, cognitively intact (Abbreviated Mental Test Score 7 or greater), able to give informed consent and admitted directly through the emergency department with a fractured neck of the femur requiring operative repair. Patients randomised to tight blood pressure control or avoidance of intra-operative hypotension will receive active treatment as required to maintain both of the following: systolic arterial blood pressure >80% of baseline pre-operative value and mean arterial pressure >75 mmHg throughout. All participants will receive standard hospital care, including spinal or general anaesthesia, at the discretion of the clinical team. The primary outcome is a composite of the presence or absence of defined cardiovascular, renal and delirium morbidity within 7 days of surgery (myocardial injury, stroke, acute kidney injury, delirium). Secondary endpoints will include the defined individual morbidities, mortality, early mobility and discharge to usual residence. This is a small-scale pilot study investigating the feasibility of a trial of tight intra-operative blood pressure control in a frail elderly patient group with known high morbidity

  2. Nursing Music Protocol and Postoperative Pain.

    Science.gov (United States)

    Poulsen, Michael J; Coto, Jeffrey

    2018-04-01

    Pain has always been a major concern for patients and nurses during the postoperative period. Therapies, medicines, and protocols have been developed to improve pain and anxiety but have undesirable risks to the patient. Complementary and alternative medicine therapies have been studied but have not been applied as regular protocols in the hospital setting. Music is one type of complementary and alternative medicine therapy that has been reported to have favorable results on reducing postoperative pain, anxiety, and opioid usage. However, music lacks a protocol that nurses can implement during the perioperative process. This paper is an in-depth literature review assessing a best practice recommendation and protocol that establishes a consensus in the use of music therapy. The results suggest that music therapy may consist of calming, soft tones of 60-80 beats per minute for at least 15-30 minutes at least twice daily during the pre- and postoperative periods. It is suggested that music only be used in conjunction with standards of care and not as the primary intervention of pain or anxiety. This evidence suggests that proper use of music therapy can significantly reduce surgical pain. Implementing these protocols and allowing the freedom of nursing staff to use them may lead to greater reductions in surgical pain and anxiety and a reduction in opioid use. Copyright © 2017 American Society for Pain Management Nursing. Published by Elsevier Inc. All rights reserved.

  3. Protocol Monitoring Energy Conservation; Protocol Monitoring Energiebesparing

    Energy Technology Data Exchange (ETDEWEB)

    Boonekamp, P.G.M. [ECN Beleidsstudies, Petten (Netherlands); Mannaerts, H. [Centraal Planburea CPB, Den Haag (Netherlands); Tinbergen, W. [Centraal Bureau voor de Statistiek CBS, Den Haag (Netherlands); Vreuls, H.H.J. [Nederlandse onderneming voor energie en milieu Novem, Utrecht (Netherlands); Wesselink, B. [Rijksinstituut voor Volksgezondheid en Milieuhygiene RIVM, Bilthoven (Netherlands)

    2001-12-01

    On request of the Dutch ministry of Economic Affairs five institutes have collaborated to create a 'Protocol Monitoring Energy Conservation', a common method and database to calculate the amount of energy savings realised in past years. The institutes concerned are the Central Bureau of Statistics (CBS), the Netherlands Bureau for Economic Policy Analysis (CPB), the Energy research Centre of the Netherlands (ECN), the National Agency for Energy and Environment (Novem) and the Netherlands Institute of Public Health and the Environment (RIVM). The institutes have agreed upon a clear definition of energy use and energy savings. The demarcation with renewable energy, the saving effects of substitution between energy carriers and the role of import and export of energy have been elaborated. A decomposition method is used to split up the observed change in energy use in a number of effects, on a national and sectoral level. This method includes an analysis of growth effects, effects of structural changes in production and consumption activities and savings on end use or with more efficient conversion processes. To calculate these effects the total energy use is desegregated as much as possible. For each segment a reference energy use is calculated according to the trend in a variable which is supposed to be representative for the use without savings. The difference with the actual energy use is taken as the savings realised. Results are given for the sectors households, industry, agriculture, services and government, transportation and the energy sector; as well as a national figure. A special feature of the protocol method is the application of primary energy use figures in the determination of savings for end users. This means that the use of each energy carrier is increased with a certain amount, according to the conversion losses caused elsewhere in the energy system. The losses concern the base year energy sector and losses abroad for imports of secondary

  4. Ambient Layer-by-Layer ZnO Assembly for Highly Efficient Polymer Bulk Heterojunction Solar Cells

    KAUST Repository

    Eita, Mohamed Samir; El Labban, Abdulrahman; Cruciani, Federico; Usman, Anwar; Beaujuge, Pierre; Mohammed, Omar F.

    2015-01-01

    The use of metal oxide interlayers in polymer solar cells has great potential because metal oxides are abundant, thermally stable, and can be used in fl exible devices. Here, a layer-by-layer (LbL) protocol is reported as a facile, room

  5. Modelling the protocol stack in NCS with deterministic and stochastic petri net

    Science.gov (United States)

    Hui, Chen; Chunjie, Zhou; Weifeng, Zhu

    2011-06-01

    Protocol stack is the basis of the networked control systems (NCS). Full or partial reconfiguration of protocol stack offers both optimised communication service and system performance. Nowadays, field testing is unrealistic to determine the performance of reconfigurable protocol stack; and the Petri net formal description technique offers the best combination of intuitive representation, tool support and analytical capabilities. Traditionally, separation between the different layers of the OSI model has been a common practice. Nevertheless, such a layered modelling analysis framework of protocol stack leads to the lack of global optimisation for protocol reconfiguration. In this article, we proposed a general modelling analysis framework for NCS based on the cross-layer concept, which is to establish an efficiency system scheduling model through abstracting the time constraint, the task interrelation, the processor and the bus sub-models from upper and lower layers (application, data link and physical layer). Cross-layer design can help to overcome the inadequacy of global optimisation based on information sharing between protocol layers. To illustrate the framework, we take controller area network (CAN) as a case study. The simulation results of deterministic and stochastic Petri-net (DSPN) model can help us adjust the message scheduling scheme and obtain better system performance.

  6. The 5x1 DAFNE study protocol: a cluster randomised trial comparing a standard 5 day DAFNE course delivered over 1 week against DAFNE training delivered over 1 day a week for 5 consecutive weeks

    Directory of Open Access Journals (Sweden)

    Elliott Jackie

    2012-11-01

    Full Text Available Abstract Background Structured education programmes are now established as an essential component to assist effective self-management of diabetes. In the case of Type 1 diabetes, the Dose Adjustment For Normal Eating (DAFNE programme improves both glycaemic control and quality of life. Traditionally delivered over five consecutive days, this format has been cited as a barrier to participation by some patients, such as those who work full-time. Some centres in the UK have organised structured education programmes to be delivered one day a week over several consecutive weeks. This type of format may add benefit by allowing more time in which to practice skills between sessions, but may suffer as a result of weaker peer support being generated compared to that formed over five consecutive days. Methods/design We aim to compare DAFNE delivered over five consecutive days (1 week course with DAFNE delivered one day a week over five weeks (5 week course in a randomised controlled trial. A total of 213 patients were randomised to attend either a 1 week or a 5 week course delivered in seven participating centres. Study outcomes (measured at baseline, 6 and 12 months post-course include HbA1c, weight, self-reported rates of severe hypoglycaemia, psychosocial measures of quality of life, and cost-effectiveness. Generalisability was optimised by recruiting patients from DAFNE waiting lists at each centre, and by mailing eligible patients from hospital clinic lists. The inclusion and exclusion criteria were identical to those used to recruit to a standard DAFNE course (e.g., HbA1c Discussion This trial has been designed to test the hypothesis that the benefits of delivering a structured education programme over 5 weeks are comparable to those observed after a 1 week course. The results of the trial and the qualitative sub-study will both inform the design and delivery of future DAFNE courses, and the development of structured education programmes in other

  7. Utilizing Cross-Layer Information to Improve Performance in JPEG2000 Decoding

    Directory of Open Access Journals (Sweden)

    Hannes Persson

    2007-01-01

    Full Text Available We focus on wireless multimedia communication and investigate how cross-layer information can be used to improve performance at the application layer, using JPEG2000 as an example. The cross-layer information is in the form of soft information from the physical layer. The soft information, which is supplied by a soft decision demodulator, yields reliability measures for the received bits and is fed into two soft input iterative JPEG2000 image decoders. When errors are detected with the error detecting mechanisms in JPEG2000, the decoders utilize the soft information to point out likely transmission errors. Hence, the decoders can correct errors and increase the image quality without making time-consuming retransmissions. We believe that the proposed decoding method utilizing soft information is suitable for a general IP-based network and that it keeps the principles of a layered structure of the protocol stack intact. Further, experimental results with images transmitted over a simulated wireless channel show that a simple decoding algorithm that utilizes soft information can give high gains in image quality compared to the standard hard-decision decoding.

  8. Immunocytochemical methods and protocols

    National Research Council Canada - National Science Library

    Javois, Lorette C

    1999-01-01

    ... monoclonal antibodies to study cell differentiation during embryonic development. For a select few disciplines volumes have been published focusing on the specific application of immunocytochemical techniques to that discipline. What distinguished Immunocytochemical Methods and Protocols from earlier books when it was first published four years ago was i...

  9. Linear Logical Voting Protocols

    DEFF Research Database (Denmark)

    DeYoung, Henry; Schürmann, Carsten

    2012-01-01

    Current approaches to electronic implementations of voting protocols involve translating legal text to source code of an imperative programming language. Because the gap between legal text and source code is very large, it is difficult to trust that the program meets its legal specification. In r...

  10. Principles of Protocol Design

    DEFF Research Database (Denmark)

    Sharp, Robin

    This is a new and updated edition of a book first published in 1994. The book introduces the reader to the principles used in the construction of a large range of modern data communication protocols, as used in distributed computer systems of all kinds. The approach taken is rather a formal one...

  11. UV Impacts Avoided by the Montreal Protocol

    Science.gov (United States)

    Newman, Paul; McKenzie, Richard

    2010-01-01

    Temporal and geographical variabilities in the future "World Expected" UV environment are compared with the "World Avoided", which would have occurred without the Montreal Protocol on protection of the ozone layer and its subsequent amendments and adjustments. Based on calculations of clear-sky UV irradiances, the effects of the Montreal Protocol have been hugely beneficial to avoid the health risks, such as skin cancer, which are associated with high UV, while there is only a small increase in health risks, such as vitamin D deficiency, that are associated with low UV. However, interactions with climate change may lead to changes in cloud and albedo, and possibly behavioural changes which could also be important.

  12. Protocols for pressure ulcer prevention: are they evidence-based?

    Science.gov (United States)

    Chaves, Lidice M; Grypdonck, Mieke H F; Defloor, Tom

    2010-03-01

    This study is a report of a study to determine the quality of protocols for pressure ulcer prevention in home care in the Netherlands. If pressure ulcer prevention protocols are evidence-based and practitioners use them correctly in practice, this will result a reduction in pressure ulcers. Very little is known about the evidence-based content and quality of the pressure ulcer prevention protocols. In 2008, current pressure ulcer prevention protocols from 24 home-care agencies in the Netherlands were evaluated. A checklist developed and validated by two pressure ulcer prevention experts was used to assess the quality of the protocols, and weighted and unweighted quality scores were computed and analysed using descriptive statistics. The 24 pressure ulcer prevention protocols had a mean weighted quality score of 63.38 points out of a maximum of 100 (sd 5). The importance of observing the skin at the pressure points at least once a day was emphasized in 75% of the protocols. Only 42% correctly warned against the use of materials that were 'less effective or that could potentially cause harm'. Pressure ulcer prevention commands a reasonable amount of attention in home care, but the incidence of pressure ulcers and lack of a consistent, standardized document for use in actual practice indicate a need for systematic implementation of national pressure ulcer prevention standards in the Netherlands to ensure adherence to the established protocols.

  13. Model Additional Protocol

    International Nuclear Information System (INIS)

    Rockwood, Laura

    2001-01-01

    Since the end of the cold war a series of events has changed the circumstances and requirements of the safeguards system. The discovery of a clandestine nuclear weapons program in Iraq, the continuing difficulty in verifying the initial report of Democratic People's Republic of Korea upon entry into force of their safeguards agreement, and the decision of the South African Government to give up its nuclear weapons program and join the Treaty on the Non-Proliferation of Nuclear Weapons have all played a role in an ambitious effort by IAEA Member States and the Secretariat to strengthen the safeguards system. A major milestone in this effort was reached in May 1997 when the IAEA Board of Governors approved a Model Protocol Additional to Safeguards Agreements. The Model Additional Protocol was negotiated over a period of less than a year by an open-ended committee of the Board involving some 70 Member States and two regional inspectorates. The IAEA is now in the process of negotiating additional protocols, State by State, and implementing them. These additional protocols will provide the IAEA with rights of access to information about all activities related to the use of nuclear material in States with comprehensive safeguards agreements and greatly expanded physical access for IAEA inspectors to confirm or verify this information. In conjunction with this, the IAEA is working on the integration of these measures with those provided for in comprehensive safeguards agreements, with a view to maximizing the effectiveness and efficiency, within available resources, the implementation of safeguards. Details concerning the Model Additional Protocol are given. (author)

  14. Study on Cloud Security Based on Trust Spanning Tree Protocol

    Science.gov (United States)

    Lai, Yingxu; Liu, Zenghui; Pan, Qiuyue; Liu, Jing

    2015-09-01

    Attacks executed on Spanning Tree Protocol (STP) expose the weakness of link layer protocols and put the higher layers in jeopardy. Although the problems have been studied for many years and various solutions have been proposed, many security issues remain. To enhance the security and credibility of layer-2 network, we propose a trust-based spanning tree protocol aiming at achieving a higher credibility of LAN switch with a simple and lightweight authentication mechanism. If correctly implemented in each trusted switch, the authentication of trust-based STP can guarantee the credibility of topology information that is announced to other switch in the LAN. To verify the enforcement of the trusted protocol, we present a new trust evaluation method of the STP using a specification-based state model. We implement a prototype of trust-based STP to investigate its practicality. Experiment shows that the trusted protocol can achieve security goals and effectively avoid STP attacks with a lower computation overhead and good convergence performance.

  15. Optimizing the high-resolution manometry (HRM) study protocol.

    Science.gov (United States)

    Patel, A; Ding, A; Mirza, F; Gyawali, C P

    2015-02-01

    Intolerance of the esophageal manometry catheter may prolong high-resolution manometry (HRM) studies and increase patient distress. We assessed the impact of obtaining the landmark phase at the end of the study when the patient has acclimatized to the HRM catheter. 366 patients (mean age 55.4 ± 0.8 years, 62.0% female) undergoing esophageal HRM over a 1-year period were studied. The standard protocol consisted of the landmark phase, 10 5 mL water swallows 20-30 s apart, and multiple rapid swallows where 4-6 2 mL swallows were administered in rapid succession. The modified protocol consisted of the landmark phase at the end of the study after test swallows. Study duration, technical characteristics, indications, and motor findings were compared between standard and modified protocols. Of the 366 patients, 89.6% underwent the standard protocol (study duration 12.9 ± 0.3 min). In 10.4% with poor catheter tolerance undergoing the modified protocol, study duration was significantly longer (15.6 ± 1.0 min, p = 0.004) despite similar duration of study maneuvers. Only elevated upper esophageal sphincter basal pressures at the beginning of the study segregated modified protocol patients. The 95th percentile time to landmark phase in the standard protocol patients was 6.1 min; as many as 31.4% of modified protocol patients could not obtain their first study maneuver within this period (p = 0.0003). Interpretation was not impacted by shifting the landmark phase to the end of the study. Modification of the HRM study protocol with the landmark phase obtained at the end of the study optimizes study duration without compromising quality. © 2014 John Wiley & Sons Ltd.

  16. Building America House Simulation Protocols (Revised)

    Energy Technology Data Exchange (ETDEWEB)

    Hendron, R.; Engebrecht, C.

    2010-10-01

    The House Simulation Protocol document was developed to track and manage progress toward Building America's multi-year, average whole-building energy reduction research goals for new construction and existing homes, using a consistent analytical reference point. This report summarizes the guidelines for developing and reporting these analytical results in a consistent and meaningful manner for all home energy uses using standard operating conditions.

  17. D-RATS 2011: RAFT Protocol Overview

    Science.gov (United States)

    Utz, Hans

    2011-01-01

    A brief overview presentation on the protocol used during the D-RATS2011 field test for file transfer from the field-test robots at Black Point Lava Flow AZ to Johnson Space Center, Houston TX over a simulated time-delay. The file transfer actually uses a commercial implementation of an open communications standard. The focus of the work lies on how to make the state of the distributed system observable.

  18. Layering and Ordering in Electrochemical Double Layers

    Energy Technology Data Exchange (ETDEWEB)

    Liu, Yihua [Materials Science Division, Argonne National Laboratory, Argonne, Illinois 60439, United States; Kawaguchi, Tomoya [Materials Science Division, Argonne National Laboratory, Argonne, Illinois 60439, United States; Pierce, Michael S. [Rochester Institute of Technology, School of Physics and Astronomy, Rochester, New York 14623, United States; Komanicky, Vladimir [Faculty of Science, Safarik University, 041 54 Kosice, Slovakia; You, Hoydoo [Materials Science Division, Argonne National Laboratory, Argonne, Illinois 60439, United States

    2018-02-26

    Electrochemical double layers (EDL) form at electrified interfaces. While Gouy-Chapman model describes moderately charged EDL, formation of Stern layers was predicted for highly charged EDL. Our results provide structural evidence for a Stern layer of cations, at potentials close to hydrogen evolution in alkali fluoride and chloride electrolytes. Layering was observed by x-ray crystal truncation rods and atomic-scale recoil responses of Pt(111) surface layers. Ordering in the layer is confirmed by glancing-incidence in-plane diffraction measurements.

  19. Protocol independent transmission method in software defined optical network

    Science.gov (United States)

    Liu, Yuze; Li, Hui; Hou, Yanfang; Qiu, Yajun; Ji, Yuefeng

    2016-10-01

    With the development of big data and cloud computing technology, the traditional software-defined network is facing new challenges (e.i., ubiquitous accessibility, higher bandwidth, more flexible management and greater security). Using a proprietary protocol or encoding format is a way to improve information security. However, the flow, which carried by proprietary protocol or code, cannot go through the traditional IP network. In addition, ultra- high-definition video transmission service once again become a hot spot. Traditionally, in the IP network, the Serial Digital Interface (SDI) signal must be compressed. This approach offers additional advantages but also bring some disadvantages such as signal degradation and high latency. To some extent, HD-SDI can also be regard as a proprietary protocol, which need transparent transmission such as optical channel. However, traditional optical networks cannot support flexible traffics . In response to aforementioned challenges for future network, one immediate solution would be to use NFV technology to abstract the network infrastructure and provide an all-optical switching topology graph for the SDN control plane. This paper proposes a new service-based software defined optical network architecture, including an infrastructure layer, a virtualization layer, a service abstract layer and an application layer. We then dwell on the corresponding service providing method in order to implement the protocol-independent transport. Finally, we experimentally evaluate that proposed service providing method can be applied to transmit the HD-SDI signal in the software-defined optical network.

  20. On the security of the Mobile IP protocol family

    NARCIS (Netherlands)

    Meyer, Ulrike; Tschofenig, Hannes; Karagiannis, Georgios; Devetsikiotis, M.; Michailidis, G.

    2007-01-01

    The Internet Engineering Task Force (IETF) has worked on network layer mobility for more than 10 years and a number of RFCs are available by now. Although the IETF mobility protocols are not present in the Internet infrastructure as of today, deployment seems to be imminent since a number of

  1. The importance of the Montreal Protocol in protecting climate

    NARCIS (Netherlands)

    Velders, G.J.M.; Andersen, S.O.; Daniel, J.S.; Fahey, D.W.; McFarland, M.

    2007-01-01

    The 1987 Montreal Protocol on Substances that Deplete the Ozone Layer is a landmark agreement that has successfully reduced the global production, consumption, and emissions of ozone-depleting substances (ODSs). ODSs are also greenhouse gases that contribute to the radiative forcing of climate

  2. Biologic comparison of partial breast irradiation protocols

    International Nuclear Information System (INIS)

    Rosenstein, Barry S.; Lymberis, Stella C.; Formenti, Silvia C.

    2004-01-01

    Purpose: To analyze the dose/fractionation schedules currently used in ongoing clinical trials of partial breast irradiation (PBI) by comparing their biologically effective dose (BED) values to those of three standard whole breast protocols commonly used after segmental mastectomy in the treatment of breast cancer. Methods and materials: The BED equation derived from the linear-quadratic model for radiation-induced cell killing was used to calculate the BEDs for three commonly used whole breast radiotherapy regimens, in addition to a variety of external beam radiotherapy, as well as high-dose-rate and low-dose-rate brachytherapy, PBI protocols. Results: The BED values of most PBI protocols resulted in tumor control BEDs roughly equivalent to a 50-Gy standard treatment, but consistently lower than the BEDs for regimens in which the tumor bed receives a total dose of either 60 Gy or 66 Gy. The BED values calculated for the acute radiation responses of erythema and desquamation were nearly all lower for the PBI schedules, and the late-response BEDs for most PBI regimens were in a similar range to the BEDs for the standard treatments. Conclusion: Biologically effective dose modeling raises the concern that inadequate doses might be delivered by PBI to ensure optimal in-field tumor control

  3. A SURVEY ON MULTICAST ROUTING PROTOCOLS FOR PERFORMANCE EVALUATION IN WIRELESS SENSOR NETWORK

    Directory of Open Access Journals (Sweden)

    A. Suruliandi

    2015-03-01

    Full Text Available Multicast is a process used to transfer same message to multiple receivers at the same time. This paper presents the simulation and analysis of the performance of six different multicast routing protocols for Wireless Sensor Network (WSN. They are On Demand Multicast Routing Protocol (ODMRP, Protocol for Unified Multicasting through Announcement (PUMA, Multicast Adhoc On demand Distance Vector Protocol (MAODV, Overlay Boruvka-based Adhoc Multicast Protocol (OBAMP, Application Layer Multicast Algorithm (ALMA and enhanced version of ALMA (ALMA-H for WSN. Among them, ODMRP, MAODV and PUMA are reactive protocols while OBAMP, ALMA and ALMA-H are proactive protocols. This paper compares the performance of these protocols with common parameters such as Throughput, Reliability, End-to-End delay and Packet Delivery Ratio (PDR with increasing the numbers of nodes and increasing the speed of the nodes. The main objective of this work is to select the efficient multicast routing protocol for WSN among six multicast routing protocol based on relative strength and weakness of each protocol. The summary of above six multicast routing protocols is presented with a table of different performance characteristics. Experimental result shows that ODMRP attains higher throughput, reliability and higher packet delivery ratio than other multicast routing protocol, while incurring far less end-to-end delay.

  4. The Performance of a Second Generation Service Discovery Protocol In Response to Message Loss

    NARCIS (Netherlands)

    Sundramoorthy, V.; van de Glind, G.J.; Hartel, Pieter H.; Scholten, Johan

    We analyze the behavior of FRODO, a second generation service discovery protocol, in response to message loss in the network. Earlier protocols, like UPnP and Jini rely on underlying network layers to enhance their failure recovery. A comparison with UPnP and Jini shows that FRODO performs more

  5. The Performance of a Second Generation Service Discovery Protocol In Response to Message Loss

    NARCIS (Netherlands)

    Sundramoorthy, V.; van de Glind, G.J.; Hartel, Pieter H.; Scholten, Johan

    We analyze the behavior of FRODO, a second generation service discovery protocol, in response to message loss in the network. First generation protocols, like UPnP and Jini rely on underlying network layers to enhance their failure recovery. A comparison with UPnP and Jini shows that FRODO performs

  6. ['Gold standard', not 'golden standard'

    NARCIS (Netherlands)

    Claassen, J.A.H.R.

    2005-01-01

    In medical literature, both 'gold standard' and 'golden standard' are employed to describe a reference test used for comparison with a novel method. The term 'gold standard' in its current sense in medical research was coined by Rudd in 1979, in reference to the monetary gold standard. In the same

  7. Epistemic Protocols for Distributed Gossiping

    Directory of Open Access Journals (Sweden)

    Krzysztof R. Apt

    2016-06-01

    Full Text Available Gossip protocols aim at arriving, by means of point-to-point or group communications, at a situation in which all the agents know each other's secrets. We consider distributed gossip protocols which are expressed by means of epistemic logic. We provide an operational semantics of such protocols and set up an appropriate framework to argue about their correctness. Then we analyze specific protocols for complete graphs and for directed rings.

  8. Symmetric cryptographic protocols

    CERN Document Server

    Ramkumar, Mahalingam

    2014-01-01

    This book focuses on protocols and constructions that make good use of symmetric pseudo random functions (PRF) like block ciphers and hash functions - the building blocks for symmetric cryptography. Readers will benefit from detailed discussion of several strategies for utilizing symmetric PRFs. Coverage includes various key distribution strategies for unicast, broadcast and multicast security, and strategies for constructing efficient digests of dynamic databases using binary hash trees.   •        Provides detailed coverage of symmetric key protocols •        Describes various applications of symmetric building blocks •        Includes strategies for constructing compact and efficient digests of dynamic databases

  9. Diplomacy and Diplomatic Protocol

    Directory of Open Access Journals (Sweden)

    Lect. Ph.D Oana Iucu

    2008-12-01

    Full Text Available The present study aims to observe relationships and determining factors between diplomacyand diplomatic protocol as outlined by historical and contextual analyses. The approach is very dynamic,provided that concepts are able to show their richness, antiquity and polyvalence at the level of connotations,semantics, grammatical and social syntax. The fact that this information is up to date determines anattitude of appreciation and a state of positive contamination.

  10. Decommissioning standards

    International Nuclear Information System (INIS)

    Crofford, W.N.

    1980-01-01

    EPA has agreed to establish a series of environmental standards for the safe disposal of radioactive waste through participation in the Interagency Review Group on Nuclear Waste Management (IRG). One of the standards required under the IRG is the standard for decommissioning of radioactive contaminated sites, facilities, and materials. This standard is to be proposed by December 1980 and promulgated by December 1981. Several considerations are important in establishing these standards. This study includes discussions of some of these considerations and attempts to evaluate their relative importance. Items covered include: the form of the standards, timing for decommissioning, occupational radiation protection, costs and financial provisions. 4 refs

  11. Automatic Validation of Protocol Narration

    DEFF Research Database (Denmark)

    Bodei, Chiara; Buchholtz, Mikael; Degano, Pierpablo

    2003-01-01

    We perform a systematic expansion of protocol narrations into terms of a process algebra in order to make precise some of the detailed checks that need to be made in a protocol. We then apply static analysis technology to develop an automatic validation procedure for protocols. Finally, we...

  12. Dysphonia risk screening protocol

    Directory of Open Access Journals (Sweden)

    Katia Nemr

    2016-03-01

    Full Text Available OBJECTIVE: To propose and test the applicability of a dysphonia risk screening protocol with score calculation in individuals with and without dysphonia. METHOD: This descriptive cross-sectional study included 365 individuals (41 children, 142 adult women, 91 adult men and 91 seniors divided into a dysphonic group and a non-dysphonic group. The protocol consisted of 18 questions and a score was calculated using a 10-cm visual analog scale. The measured value on the visual analog scale was added to the overall score, along with other partial scores. Speech samples allowed for analysis/assessment of the overall degree of vocal deviation and initial definition of the respective groups and after six months, the separation of the groups was confirmed using an acoustic analysis. RESULTS: The mean total scores were different between the groups in all samples. Values ranged between 37.0 and 57.85 in the dysphonic group and between 12.95 and 19.28 in the non-dysphonic group, with overall means of 46.09 and 15.55, respectively. High sensitivity and specificity were demonstrated when discriminating between the groups with the following cut-off points: 22.50 (children, 29.25 (adult women, 22.75 (adult men, and 27.10 (seniors. CONCLUSION: The protocol demonstrated high sensitivity and specificity in differentiating groups of individuals with and without dysphonia in different sample groups and is thus an effective instrument for use in voice clinics.

  13. Dysphonia risk screening protocol

    Science.gov (United States)

    Nemr, Katia; Simões-Zenari, Marcia; da Trindade Duarte, João Marcos; Lobrigate, Karen Elena; Bagatini, Flavia Alves

    2016-01-01

    OBJECTIVE: To propose and test the applicability of a dysphonia risk screening protocol with score calculation in individuals with and without dysphonia. METHOD: This descriptive cross-sectional study included 365 individuals (41 children, 142 adult women, 91 adult men and 91 seniors) divided into a dysphonic group and a non-dysphonic group. The protocol consisted of 18 questions and a score was calculated using a 10-cm visual analog scale. The measured value on the visual analog scale was added to the overall score, along with other partial scores. Speech samples allowed for analysis/assessment of the overall degree of vocal deviation and initial definition of the respective groups and after six months, the separation of the groups was confirmed using an acoustic analysis. RESULTS: The mean total scores were different between the groups in all samples. Values ranged between 37.0 and 57.85 in the dysphonic group and between 12.95 and 19.28 in the non-dysphonic group, with overall means of 46.09 and 15.55, respectively. High sensitivity and specificity were demonstrated when discriminating between the groups with the following cut-off points: 22.50 (children), 29.25 (adult women), 22.75 (adult men), and 27.10 (seniors). CONCLUSION: The protocol demonstrated high sensitivity and specificity in differentiating groups of individuals with and without dysphonia in different sample groups and is thus an effective instrument for use in voice clinics. PMID:27074171

  14. Formalizing and proving a typing result for security protocols in Isabelle/HOL

    DEFF Research Database (Denmark)

    Hess, Andreas Viktor; Modersheim, Sebastian

    2017-01-01

    or the positive output of a verification tool. However several of these works have used a typed model, where the intruder is restricted to "well-typed" attacks. There also have been several works that show that this is actually not a restriction for a large class of protocols, but all these results so far...... are again pen-and-paper proofs. In this work we present a formalization of such a typing result in Isabelle/HOL. We formalize a constraint-based approach that is used in the proof argument of such typing results, and prove its soundness, completeness and termination. We then formalize and prove the typing...... result itself in Isabelle. Finally, to illustrate the real-world feasibility, we prove that the standard Transport Layer Security (TLS) handshake satisfies the main condition of the typing result....

  15. A concept to standardize raw biosignal transmission for brain-computer interfaces.

    Science.gov (United States)

    Breitwieser, Christian; Neuper, Christa; Müller-Putz, Gernot R

    2011-01-01

    With this concept we introduced the attempt of a standardized interface called TiA to transmit raw biosignals. TiA is able to deal with multirate and block-oriented data transmission. Data is distinguished by different signal types (e.g., EEG, EOG, NIRS, …), whereby those signals can be acquired at the same time from different acquisition devices. TiA is built as a client-server model. Multiple clients can connect to one server. Information is exchanged via a control- and a separated data connection. Control commands and meta information are transmitted over the control connection. Raw biosignal data is delivered using the data connection in a unidirectional way. For this purpose a standardized handshaking protocol and raw data packet have been developed. Thus, an abstraction layer between hardware devices and data processing was evolved facilitating standardization.

  16. Telomerase Repeated Amplification Protocol (TRAP).

    Science.gov (United States)

    Mender, Ilgen; Shay, Jerry W

    2015-11-20

    Telomeres are found at the end of eukaryotic linear chromosomes, and proteins that bind to telomeres protect DNA from being recognized as double-strand breaks thus preventing end-to-end fusions (Griffith et al. , 1999). However, due to the end replication problem and other factors such as oxidative damage, the limited life span of cultured cells (Hayflick limit) results in progressive shortening of these protective structures (Hayflick and Moorhead, 1961; Olovnikov, 1973). The ribonucleoprotein enzyme complex telomerase-consisting of a protein catalytic component hTERT and a functional RNA component hTR or hTERC - counteracts telomere shortening by adding telomeric repeats to the end of chromosomes in ~90% of primary human tumors and in some transiently proliferating stem-like cells (Shay and Wright, 1996; Shay and Wright, 2001). This results in continuous proliferation of cells which is a hallmark of cancer. Therefore, telomere biology has a central role in aging, cancer progression/metastasis as well as targeted cancer therapies. There are commonly used methods in telomere biology such as Telomere Restriction Fragment (TRF) (Mender and Shay, 2015b), Telomere Repeat Amplification Protocol (TRAP) and Telomere dysfunction Induced Foci (TIF) analysis (Mender and Shay, 2015a). In this detailed protocol we describe Telomere Repeat Amplification Protocol (TRAP). The TRAP assay is a popular method to determine telomerase activity in mammalian cells and tissue samples (Kim et al. , 1994). The TRAP assay includes three steps: extension, amplification, and detection of telomerase products. In the extension step, telomeric repeats are added to the telomerase substrate (which is actually a non telomeric oligonucleotide, TS) by telomerase. In the amplification step, the extension products are amplified by the polymerase chain reaction (PCR) using specific primers (TS upstream primer and ACX downstream primer) and in the detection step, the presence or absence of telomerase is

  17. Protocol design and analysis for cooperative wireless networks

    CERN Document Server

    Song, Wei; Jin, A-Long

    2017-01-01

    This book focuses on the design and analysis of protocols for cooperative wireless networks, especially at the medium access control (MAC) layer and for crosslayer design between the MAC layer and the physical layer. It highlights two main points that are often neglected in other books: energy-efficiency and spatial random distribution of wireless devices. Effective methods in stochastic geometry for the design and analysis of wireless networks are also explored. After providing a comprehensive review of existing studies in the literature, the authors point out the challenges that are worth further investigation. Then, they introduce several novel solutions for cooperative wireless network protocols that reduce energy consumption and address spatial random distribution of wireless nodes. For each solution, the book offers a clear system model and problem formulation, details of the proposed cooperative schemes, comprehensive performance analysis, and extensive numerical and simulation results that validate th...

  18. Diagnostic Accuracy of Spectralis SD OCT Automated Macular Layers Segmentation to Discriminate Normal from Early Glaucomatous Eyes.

    Science.gov (United States)

    Pazos, Marta; Dyrda, Agnieszka Anna; Biarnés, Marc; Gómez, Alicia; Martín, Carlos; Mora, Clara; Fatti, Gianluca; Antón, Alfonso

    2017-08-01

    To evaluate the accuracy of the macular retinal layer segmentation software of the Spectralis spectral-domain (SD) optical coherence tomography (OCT) device (Heidelberg Engineering, Inc., Heidelberg, Germany) to discriminate between healthy and early glaucoma (EG) eyes. Prospective, cross-sectional study. Forty EG eyes and 40 healthy controls were included. All participants were examined using the standard posterior pole and the peripapillary retinal nerve fiber layer (pRNFL) protocols of the Spectralis OCT device. Using an Early Treatment Diagnostic Retinopathy Study circle at the macular level, the automated retinal segmentation software was applied to determine thicknesses of the following parameters: total retinal thickness, inner retinal layer (IRL), macular retinal nerve fiber layer (mRNFL), macular ganglion cell layer (mGCL), macular inner plexiform layer (mIPL), macular inner nuclear layer (mINL), macular outer plexiform layer (mOPL), macular outer nuclear layer (mONL), photoreceptors (PR), and retinal pigmentary epithelium (RPE). The ganglion cell complex (GCC) was determined by adding the mRNFL, mGCL, and mIPL parameters and the ganglion cell layer-inner plexiform layer (mGCL-IPL) was determined by combining the mGCL and mIPL parameters. Thickness of each layer was compared between the groups, and the layer and sector with the best area under the receiver operating characteristic curve (AUC) were identified. Comparison of pRNFL, IRL, mRNFL, mGCL, mIPL, mGCC, mGCL-IPL, mINL, mOPL, mONL, PR, and RPE parameters and total retinal thicknesses between groups for the different areas and their corresponding AUCs. Peripapillary RNFL was significantly thinner in the EG group globally and in all 6 sectors assessed (P < 0.0005). For the macular variables, retinal thickness was significantly reduced in the EG group for total retinal thickness, mIRL, mRNFL, mGCL, and mIPL. The 2 best isolated parameters to discriminate between the 2 groups were pRNFL (AUC, 0.956) and

  19. Accounting standards

    NARCIS (Netherlands)

    Stellinga, B.; Mügge, D.

    2014-01-01

    The European and global regulation of accounting standards have witnessed remarkable changes over the past twenty years. In the early 1990s, EU accounting practices were fragmented along national lines and US accounting standards were the de facto global standards. Since 2005, all EU listed

  20. Standardization Documents

    Science.gov (United States)

    2011-08-01

    Specifications and Standards; Guide Specifications; CIDs; and NGSs . Learn. Perform. Succeed. STANDARDIZATION DOCUMENTS Federal Specifications Commercial...national or international standardization document developed by a private sector association, organization, or technical society that plans ...Maintain lessons learned • Examples: Guidance for application of a technology; Lists of options Learn. Perform. Succeed. DEFENSE HANDBOOK

  1. Standardization of fertilization protocols for the European eel, Anguilla anguilla

    DEFF Research Database (Denmark)

    Butts, Ian; Sørensen, Sune Riis; Politis, Sebastian Nikitas

    2014-01-01

    of this research were to provide a rapid, accurate and precise method to quantify sperm density by examining the relationship between sperm density and absorbance by use of a spectrophotometer, determine the optimal number of sperm required to fertilize eggs in a controlled setting, and explore how long eggs...... are receptive to fertilization post-stripping. Mean sperm density and absorbance at 350nm were 1.54e+10±4.95e+9sperm/mL and 1.91±0.22nm, respectively. Regression analysis demonstrated a highly significant positive relationship between sperm density and absorbance using a spectrophotometer at 350nm (R2=0.94, p

  2. Managing orthopedics and neurosciences costs through standard treatment protocols.

    Science.gov (United States)

    McGinnity, E S; Pluth, T E

    1994-06-01

    High-cost, high-volume specialty programs such as orthopedics and neurosciences find themselves in a position of evaluating the costs and in some cases the appropriateness of medical practices in response to payer scrutiny and provider selection processes. Orthopedics and neurosciences programs are at a stage of development analogous to that of cardiovascular care several years ago. Many of the same trends have come into play, such as payer "carve-outs" for orthopedic services, payer selection of centers of excellence based on cost and quality, reduction of Medicare reimbursement, greater use of high-cost technology, the decline of profitability due to "older, sicker, and tougher" patients, and the recent emergence of national orthopedic specialty networks oriented to national contracts for care. In an era in which payers demand value on both sides of the cost-plus-quality equation, programs are challenged to maximize the return on a patient population rife with "no-win" situations. In the orthopedic service line these include a high proportion of Medicare patients and chronic conditions such as workers' compensation medical back cases or repetitive motion injuries, which can be elusive to diagnose and expensive to treat. Many hospitals continue to lose money on joint replacement surgeries, the largest-volume orthopedic inpatient service, primarily because of the high Medicare population and the cost of implants. Neuroservices, while still relatively well reimbursed, face a rising proportion of Medicare payments as patients live longer and develop chronic, degenerative conditions. Inpatient days are decreasing due to payer pressures to limit hospital stays and to shift inpatient care to outpatient services. Some hospitals "have lost interest in (the orthopedic) service line during the last five years because of recent trends in orthopedic-related inpatient volume and payment." But by managing costs strategically, both the neurosciences and orthopedics service lines can provide substantial revenue as well as the opportunity to achieve a "center of excellence" competitive position in a managed care environment. This Special Report outlines the process and advantages of managing costs and quality of care strategically, that is, in a manner which helps these programs meet internal cost and clinical goals while responding to market situations. The hospital, physicians, and patients all benefit as costs are reduced, quality is enhanced, and the service line's competitive position is strengthened.

  3. Standardized food images : A photographing protocol and image database

    NARCIS (Netherlands)

    Charbonnier, Lisette; van Meer, Floor; van der Laan, Laura N.; Viergever, Max A.; Smeets, Paul A M

    2015-01-01

    The regulation of food intake has gained much research interest because of the current obesity epidemic. For research purposes, food images are a good and convenient alternative for real food because many dietary decisions are made based on the sight of foods. Food pictures are assumed to elicit

  4. Standardized food images: A photographing protocol and image database

    NARCIS (Netherlands)

    Charbonnier, L.; Meer, van der F.; Laan, van der L.N.; Viergever, M.A.; Smeets, P.A.M.

    2016-01-01

    The regulation of food intake has gained much research interest because of the current obesity epidemic. For research purposes, food images are a good and convenient alternative for real food because many dietary decisions are made based on the sight of foods. Food pictures are assumed to elicit

  5. Photoelectrochemical water splitting standards, experimental methods, and protocols

    CERN Document Server

    Chen, Zhebo; Miller, Eric

    2014-01-01

    This book outlines many of the techniques involved in materials development and characterization for photoelectrochemical (PEC) - for example, proper metrics for describing material performance, how to assemble testing cells and prepare materials for assessment of their properties, and how to perform the experimental measurements needed to achieve reliable results towards better scientific understanding. For each technique, proper procedure, benefits, limitations, and data interpretation are discussed. Consolidating this information in a short, accessible, and easy to read reference guide will allow researchers to more rapidly immerse themselves into PEC research and also better compare their results against those of other researchers to better advance materials development. This book serves as a "how-to" guide for researchers engaged in or interested in engaging in the field of photoelectrochemical (PEC) water splitting. PEC water splitting is a rapidly growing field of research in which the goal is to deve...

  6. Assessing impacts of roads: Application of a standard assessment protocol

    Science.gov (United States)

    Adaptive management of road networks depends on timely data that accurately reflect the impacts of network impacts on ecosystem processes and associated services. In the absence of reliable data, land managers are left with little more than observations and perceptions to support adaptive management...

  7. e-SCP-ECG+ Protocol: An Expansion on SCP-ECG Protocol for Health Telemonitoring—Pilot Implementation

    Directory of Open Access Journals (Sweden)

    George J. Mandellos

    2010-01-01

    Full Text Available Standard Communication Protocol for Computer-assisted Electrocardiography (SCP-ECG provides standardized communication among different ECG devices and medical information systems. This paper extends the use of this protocol in order to be included in health monitoring systems. It introduces new sections into SCP-ECG structure for transferring data for positioning, allergies, and five additional biosignals: noninvasive blood pressure (NiBP, body temperature (Temp, Carbon dioxide (CO2, blood oxygen saturation (SPO2, and pulse rate. It also introduces new tags in existing sections for transferring comprehensive demographic data. The proposed enhanced version is referred to as e-SCP-ECG+ protocol. This paper also considers the pilot implementation of the new protocol as a software component in a Health Telemonitoring System.

  8. Network Authentication Protocol Studies

    Science.gov (United States)

    2009-04-01

    usually require compliance with development standards such as ISO 12207 or IEEE / IEC 12207 . Those standards mandate traceability as a property of a...standards have been proposed to deal with non-repudiation. ISO /IEC 10181-4 [19] and ISO /IEC 13888 [20, 22, 21]. While ISO /IEC 10181-4 provides a...framework for developing and employing these services, ISO /IEC 13888 consists of three parts. They propose a general model of non-repudiation and a set of

  9. IAEA to implement Safeguards Additional Protocols in the EU

    International Nuclear Information System (INIS)

    2004-01-01

    Full text: IAEA Director General Mohamed ElBaradei welcomed the entry into force today of the Additional Protocols for 15 States of the European Union - France, the United Kingdom and the 13 non-nuclear weapon States of the EU - and the European Atomic Energy Community (EURATOM). The Protocols, which provide the Agency with better tools to verify compliance with nuclear non-proliferation commitments, entered into force when the European Commission informed the Agency that EURATOM's own requirements for entry into force had been met. The 15 States had provided similar notifications over the past years since signing the Protocols in 1998. The simultaneous entry into force of Additional Protocols for the 15 EU States is 'a very positive development and a milestone in our efforts to strengthen the verification regime', said Dr. ElBaradei. 'In my view, the Additional Protocol should become the standard for verification under the Treaty on the Non-Proliferation of Nuclear Weapons (NPT).' He added that the Agency had been preparing for the entry into force of the EU protocols and was confident that, in co-operation with the 15 States and EURATOM, it would be able to ensure effective and efficient implementation in the EU States. The Model Additional Protocol was developed following the discovery of Iraq's clandestine nuclear weapons programme to ensure that the IAEA is given the information and access it needs for timely discovery of any similar activities in States that have pledged not to use nuclear material and activities for weapons purposes. In the past year, Additional Protocols entered into force for 22 countries, and the Agency will now implement Additional Protocols in 58 States, which includes the 15 EU States. The 10 countries joining the EU on 1 May 2004 - seven of which already have brought into force Additional Protocols to their respective safeguards agreements - are expected to gradually accede to the Safeguards Agreement and Additional Protocol covering

  10. A Scenario-Based Protocol Checker for Public-Key Authentication Scheme

    Science.gov (United States)

    Saito, Takamichi

    Security protocol provides communication security for the internet. One of the important features of it is authentication with key exchange. Its correctness is a requirement of the whole of the communication security. In this paper, we introduce three attack models realized as their attack scenarios, and provide an authentication-protocol checker for applying three attack-scenarios based on the models. We also utilize it to check two popular security protocols: Secure SHell (SSH) and Secure Socket Layer/Transport Layer Security (SSL/TLS).

  11. FRENCH PROTOCOL CARDS

    CERN Multimedia

    Division du Personnel

    1999-01-01

    Senior officials, holders of FRENCH PROTOCOL cards (blue cards) due to expire on 31.12.1999, are requested to return these cards and those of family members, for extension to:Bureau des cartes, bâtiment 33.1-025Should the 3 spaces for authentication on the back of the card be full, please enclose 2 passport photographs for a new card.In the case of children aged 14 and over, an attestation of dependency and a school certificate should be returned with the card.Personnel DivisionTel. 79494/74683

  12. FRENCH PROTOCOL CARDS

    CERN Multimedia

    Human Resources Division

    2000-01-01

    Senior officials, holders of FRENCH PROTOCOL cards (blue cards) due to expire on 31.12.2000, are requested to return these cards and those of family members, for extension to: Bureau des cartes, Bât 33.1-009/1-015 Should the three spaces for authentication on the back of the card be full, please enclose two passport photographs for a new card. In the case of children aged 14 and over, an attestation of dependency and a school certificate should be returned with the card.

  13. Sincalide - the final protocol

    International Nuclear Information System (INIS)

    Clarke, E.A.; Notghi, A.; Hesslewood, S.R.; Harding, L.K.

    2002-01-01

    Full text: HIDA biliary studies examine the gallbladder (GB) to give a percentage ejection fraction (EF). Porcine CCK was an accepted agent for stimulating the GB prior to being withdrawn in the UK from 1998. Sincalide (a synthetic CCK) was the suggested replacement. We have tried many administration regimes in an attempt to get results comparable with our established CCK protocols. Dose concentration and length of infusion times have been studied. Initially a dose of 10 ngm/kg/min given over 2 minutes (manufacturer's recommended dose) was used. This gave falsely low ejection fractions. The dose was reduced to 3 ngm/kg/min over 3 minutes as it was felt the higher dose may be causing constriction of the sphincter of Oddi. This gave a slight improvement with 22 % of patients having normal EF (>35 %). The length of infusion was extended to 15 minutes and the dose concentration reduced again to 0.6 ngm/kg/min. 62 % of patients had a normal EF. However, on many of the curves the gallbladder was still contracting on completion of the 15 minute infusion and began to refill immediately after stopping Sincalide. A further change of protocol was indicated. The infusion time was extended to 30 minutes and the dose concentration per minute kept the same. Imaging began at 30 minutes post HIDA injection and continued for a total of 50 minutes. Sincalide infusion began at 35 minutes if a GB was visualized. This protocol has been performed on 17 patients. 53 % of these had a normal result (comparable with a normal rate of 40 % previously established with CCK) with a mean EF of 60 %. The mean EF of patients with abnormal studies was 15 %. Curves showed a plateau by 30 minutes in 94 % of patients indicating that gallbladder contraction was complete. No normal range is available so results were compared with ultrasound (US). All patients who had an abnormal US scan also had abnormal HIDA results. Three patients had a normal US scan and abnormal HIDA study. These are currently

  14. Distributed Network Protocols

    Science.gov (United States)

    1980-07-01

    MONITORING AGENCY NAME & ADDRESS(II different from Controlting Office) IS. SECURITY CLASS. (of this report) S Office of Naval Research Unclassified...All protocols are extended to networks with changing. topology. S80 8 4 246 DD0I iA 1473 EDITION OF INOV 65 IS OBSOLETE 8 0 24 SECURITY CLASSIFICATION...to the netowrk . f) Each node knows its adjacent links, but not necessarily the identity of its neighbors, i.e. the nodes at the other end of the links

  15. Asymptotic analysis and boundary layers

    CERN Document Server

    Cousteix, Jean

    2007-01-01

    This book presents a new method of asymptotic analysis of boundary-layer problems, the Successive Complementary Expansion Method (SCEM). The first part is devoted to a general comprehensive presentation of the tools of asymptotic analysis. It gives the keys to understand a boundary-layer problem and explains the methods to construct an approximation. The second part is devoted to SCEM and its applications in fluid mechanics, including external and internal flows. The advantages of SCEM are discussed in comparison with the standard Method of Matched Asymptotic Expansions. In particular, for the first time, the theory of Interactive Boundary Layer is fully justified. With its chapter summaries, detailed derivations of results, discussed examples and fully worked out problems and solutions, the book is self-contained. It is written on a mathematical level accessible to graduate and post-graduate students of engineering and physics with a good knowledge in fluid mechanics. Researchers and practitioners will estee...

  16. Emulation Platform for Cyber Analysis of Wireless Communication Network Protocols

    Energy Technology Data Exchange (ETDEWEB)

    Van Leeuwen, Brian P. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Eldridge, John M. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)

    2017-11-01

    Wireless networking and mobile communications is increasing around the world and in all sectors of our lives. With increasing use, the density and complexity of the systems increase with more base stations and advanced protocols to enable higher data throughputs. The security of data transported over wireless networks must also evolve with the advances in technologies enabling more capable wireless networks. However, means for analysis of the effectiveness of security approaches and implementations used on wireless networks are lacking. More specifically a capability to analyze the lower-layer protocols (i.e., Link and Physical layers) is a major challenge. An analysis approach that incorporates protocol implementations without the need for RF emissions is necessary. In this research paper several emulation tools and custom extensions that enable an analysis platform to perform cyber security analysis of lower layer wireless networks is presented. A use case of a published exploit in the 802.11 (i.e., WiFi) protocol family is provided to demonstrate the effectiveness of the described emulation platform.

  17. Securing ARP and DHCP for mitigating link layer attacks

    Indian Academy of Sciences (India)

    Osama S Younes

    2017-11-24

    Nov 24, 2017 ... network, DHCP automates the assignment of configuration parameters of TCP/IP ... standard protocols, simple, and cost-effective. The rest of the .... DHCP ACK, are attached with the challenge-response to authenticate the ...

  18. RadNet: Open network protocol for radiation data

    International Nuclear Information System (INIS)

    Rees, B.; Olson, K.; Beckes-Talcott, J.; Kadner, S.; Wenderlich, T.; Hoy, M.; Doyle, W.; Koskelo, M.

    1998-01-01

    Safeguards instrumentation is increasingly being incorporated into remote monitoring applications. In the past, vendors of radiation monitoring instruments typically provided the tools for uploading the monitoring data to a host. However, the proprietary nature of communication protocols lends itself to increased computer support needs and increased installation expenses. As a result, a working group of suppliers and customers of radiation monitoring instruments defined an open network protocol for transferring packets on a local area network from radiation monitoring equipment to network hosts. The protocol was termed RadNet. While it is now primarily used for health physics instruments, RadNet's flexibility and strength make it ideal for remote monitoring of nuclear materials. The incorporation of standard, open protocols ensures that future work will not render present work obsolete; because RadNet utilizes standard Internet protocols, and is itself a non-proprietary standard. The use of industry standards also simplifies the development and implementation of ancillary services, e.g. E-main generation or even pager systems

  19. May the Kyoto protocol produce results?

    International Nuclear Information System (INIS)

    Jaureguy-Naudin, M.

    2009-01-01

    A not well managed drastic reduction of greenhouse emissions might result in significant decrease of living standards, but without such reduction efforts, climate change might have five to twenty times higher costs. Thus, while indicating estimated consequences or evolutions of greenhouse emissions and temperature, the author stresses the need of emission reduction. She discusses the role of economic instruments which can be used in policies aimed at the struggle against climate change. She recalls the emission reduction commitments specified in the Kyoto protocol, discusses the present status, operation and results of the international emission trading scheme, the lessons learned after the first years of operation, comments the involvement of emerging countries in relationship with another mechanism defined in the protocol: the Clean Development Mechanism

  20. Security and SCADA protocols

    International Nuclear Information System (INIS)

    Igure, V. M.; Williams, R. D.

    2006-01-01

    Supervisory control and data acquisition (SCADA) networks have replaced discrete wiring for many industrial processes, and the efficiency of the network alternative suggests a trend toward more SCADA networks in the future. This paper broadly considers SCADA to include distributed control systems (DCS) and digital control systems. These networks offer many advantages, but they also introduce potential vulnerabilities that can be exploited by adversaries. Inter-connectivity exposes SCADA networks to many of the same threats that face the public internet and many of the established defenses therefore show promise if adapted to the SCADA differences. This paper provides an overview of security issues in SCADA networks and ongoing efforts to improve the security of these networks. Initially, a few samples from the range of threats to SCADA network security are offered. Next, attention is focused on security assessment of SCADA communication protocols. Three challenges must be addressed to strengthen SCADA networks. Access control mechanisms need to be introduced or strengthened, improvements are needed inside of the network to enhance security and network monitoring, and SCADA security management improvements and policies are needed. This paper discusses each of these challenges. This paper uses the Profibus protocol as an example to illustrate some of the vulnerabilities that arise within SCADA networks. The example Profibus security assessment establishes a network model and an attacker model before proceeding to a list of example attacks. (authors)

  1. STANDARDIZATION AND VALIDATION OF METHODS FOR ENUMERATION OF FECAL COLIFORM AND SALMONELLA IN BIOSOLIDS

    Science.gov (United States)

    Current federal regulations require monitoring for fecal coliforms or Salmonella in biosolids destined for land application. Methods used for analysis of fecal coliforms and Salmonella were reviewed and a standard protocol was developed. The protocols were then evaluated by testi...

  2. Characterization of a test device for determination of the half value layer and of filtration with quality equity of materials in accordance with standard ABNT NBR IEC 60601-1-3

    International Nuclear Information System (INIS)

    Viana, Vlamir

    2012-01-01

    The motivation of this work was the development and validation of a device to perform the tests established by ABNT NBR IEC 60601-1-3 versions published in 2001 and 2011. The purpose of the tests is to determine the half-value layer – HVL and filtration with equivalent filtration quality in mmAl, materials that intercept the X-ray beam from their emission to the X-ray image receiving device. This filtration includes all the materials present in radiation source assembly, formed by the x-ray tube housing with x-ray tube inserted, the collimator (inherent filtration) and by materials present in the patients support, as Table and wall bucky, both incorporate image receiving device which is also evaluated. In the development was taken in consideration the routine of tests execution routine, in order to reduce the operator interaction with the system and in order to reduce the human factor in the execution, reflecting directly on the measurement uncertainty, in the runtime reduction of the runtime and radiation safety. The device was validated with respect to: a) Effect of positioning and distribution of the filters in the filter changer device; b) Influence of purity of the aluminum filter used in the device, and c) Comparison tests carried out with the testing device with respect to the tests carried out with a reference X-ray generator. (author)

  3. [Computerized clinical protocol for occlusion].

    Science.gov (United States)

    Salsench, J; Ferrer, J; Nogueras, J

    1988-11-01

    In making a protocol it is necessary that all members of the team who are going to collect information have the same unity of criterion about the different variables that compose it. The drawing up of this document is as much or more necessary than the protocol itself. In this work we all data collected in the protocol and we give the explanations of each concept.

  4. The FEROL40, a microTCA card interfacing custom point-to-point links and standard TCP/IP

    CERN Document Server

    Gigi, Dominique; Behrens, Ulf; Branson, James; Chaze, Olivier; Cittolin, Sergio; Contescu, Cristian; da Silva Gomes, Diego; Darlea, Georgiana-Lavinia; Deldicque, Christian; Demiragli, Zeynep; Dobson, Marc; Doualot, Nicolas; Erhan, Samim; Fulcher, Jonathan Richard; Gladki, Maciej; Glege, Frank; Gomez-Ceballos, Guillelmo; Hegeman, Jeroen; Holzner, Andre; Janulis, Mindaugas; Lettrich, Michael; Meijers, Frans; Meschi, Emilio; Mommsen, Remigius K; Morovic, Srecko; O'Dell, Vivian; Orn, Samuel Johan; Orsini, Luciano; Papakrivopoulos, Ioannis; Paus, Christoph; Petrova, Petia; Petrucci, Andrea; Pieri, Marco; Rabady, Dinyar; Racz, Attila; Reis, Thomas; Sakulin, Hannes; Schwick, Christoph; Simelevicius, Dainius; Vazquez Velez, Cristina; Vougioukas, Michail; Zejdl, Petr

    2017-01-01

    In order to accommodate new back-end electronics of upgraded CMS sub-detectors, a new FEROL40 card in the microTCA standard has been developed. The main function of the FEROL40 is to acquire event data over multiple point-to-point serial optical links, provide buffering, perform protocol conversion, and transmit multiple TCP/IP streams (4x10Gbps) to the Ethernet network of the aggregation layer of the CMS DAQ (data acquisition) event builder. This contribution discusses the design of the FEROL40 and experience from operation.

  5. Training Standardization

    International Nuclear Information System (INIS)

    Agnihotri, Newal

    2003-01-01

    The article describes the benefits of and required process and recommendations for implementing the standardization of training in the nuclear power industry in the United States and abroad. Current Information and Communication Technologies (ICT) enable training standardization in the nuclear power industry. The delivery of training through the Internet, Intranet and video over IP will facilitate this standardization and bring multiple benefits to the nuclear power industry worldwide. As the amount of available qualified and experienced professionals decreases because of retirements and fewer nuclear engineering institutions, standardized training will help increase the number of available professionals in the industry. Technology will make it possible to use the experience of retired professionals who may be interested in working part-time from a remote location. Well-planned standardized training will prevent a fragmented approach among utilities, and it will save the industry considerable resources in the long run. It will also ensure cost-effective and safe nuclear power plant operation

  6. Static Validation of Security Protocols

    DEFF Research Database (Denmark)

    Bodei, Chiara; Buchholtz, Mikael; Degano, P.

    2005-01-01

    We methodically expand protocol narrations into terms of a process algebra in order to specify some of the checks that need to be made in a protocol. We then apply static analysis technology to develop an automatic validation procedure for protocols. Finally, we demonstrate that these techniques ...... suffice to identify several authentication flaws in symmetric and asymmetric key protocols such as Needham-Schroeder symmetric key, Otway-Rees, Yahalom, Andrew secure RPC, Needham-Schroeder asymmetric key, and Beller-Chang-Yacobi MSR...

  7. Directional Medium Access Control (MAC Protocols in Wireless Ad Hoc and Sensor Networks: A Survey

    Directory of Open Access Journals (Sweden)

    David Tung Chong Wong

    2015-06-01

    Full Text Available This survey paper presents the state-of-the-art directional medium access control (MAC protocols in wireless ad hoc and sensor networks (WAHSNs. The key benefits of directional antennas over omni-directional antennas are longer communication range, less multipath interference, more spatial reuse, more secure communications, higher throughput and reduced latency. However, directional antennas lead to single-/multi-channel directional hidden/exposed terminals, deafness and neighborhood, head-of-line blocking, and MAC-layer capture which need to be overcome. Addressing these problems and benefits for directional antennas to MAC protocols leads to many classes of directional MAC protocols in WAHSNs. These classes of directional MAC protocols presented in this survey paper include single-channel, multi-channel, cooperative and cognitive directional MACs. Single-channel directional MAC protocols can be classified as contention-based or non-contention-based or hybrid-based, while multi-channel directional MAC protocols commonly use a common control channel for control packets/tones and one or more data channels for directional data transmissions. Cooperative directional MAC protocols improve throughput in WAHSNs via directional multi-rate/single-relay/multiple-relay/two frequency channels/polarization, while cognitive directional MAC protocols leverage on conventional directional MAC protocols with new twists to address dynamic spectrum access. All of these directional MAC protocols are the pillars for the design of future directional MAC protocols in WAHSNs.

  8. About the Design of QUIC Firefox Transport Protocol

    Directory of Open Access Journals (Sweden)

    Vraj Pandya

    2017-07-01

    Full Text Available QUIC (Quick UDP Internet Connections Chrome is an experimental transport layer network protocol designed by Jim Roskind at Google, initially implemented in 2012 and announced publicly in 2013. One of the QUIC's goals is to improve performance of connection-oriented web applications that are currently using the Transmission Control Protocol (TCP. To do that, QUIC achieves a reduced latency and a better stream-multiplexing support to avoid network congestion. In 2015, Firefox Mozilla started to work on an equivalent QUIC transport protocol for their browser. This idea was motivated by the differences between Chrome and Firefox. Despite the fact that Mozilla Firefox and Google Chrome are both web browser engines, there are some significant differences between them, such as file hierarchy, open source policies (Firefox is completely, while Chrome is only partial, tabs design, continuous integration, and more. Likewise QUIC Chrome, QUIC Firefox is a new multiplexed and secure transport based on User Datagram Protocol (UDP, designed from the ground up and optimized for Hyper-Text Transfer Protocol 2 (HTTP/2 semantics. While built with HTTP/2 as the primary application protocol