WorldWideScience

Sample records for prosthetic joint infections

  1. Prosthetic Joint Infections

    Science.gov (United States)

    Aslam, Saima; Darouiche, Rabih O.

    2012-01-01

    Prosthetic joint infections represent a major therapeutic challenge for both healthcare providers and patients. This paper reviews the predisposing factors, pathogenesis, microbiology, diagnosis, treatment and prophylaxis of prosthetic joint infection. The most optimal management strategy should be identified based on a number of considerations including type and duration of infection, antimicrobial susceptibility of the infecting pathogen, condition of infected tissues and bone stock, patient wishes and functional status. PMID:22847032

  2. Periprosthetic joint infection: are patients with multiple prosthetic joints at risk?

    Science.gov (United States)

    Jafari, S Mehdi; Casper, David S; Restrepo, Camilo; Zmistowski, Benjamin; Parvizi, Javad; Sharkey, Peter F

    2012-06-01

    Patients who present with a periprosthetic joint infection in a single joint may have multiple prosthetic joints. The risk of these patients developing a subsequent infection in another prosthetic joint is unknown. Our purposes were (1) to identify the risk of developing a subsequent infection in another prosthetic joint and (2) to describe the time span and organism profile to the second prosthetic infection. We retrospectively identified 55 patients with periprosthetic joint infection who had another prosthetic joint in place at the time of presentation. Of the 55 patients, 11 (20%) developed a periprosthetic joint infection in a second joint. The type of organism was the same as the first infection in 4 (36%) of 11 patients. The time to developing a second infection averaged 2.0 years (range, 0-6.9 years). Copyright © 2012 Elsevier Inc. All rights reserved.

  3. Second-site prosthetic joint infection in patients with multiple prosthetic joints.

    Science.gov (United States)

    Clesham, Kevin; Hughes, Andrew J; O' hEireamhoin, Sven; Fleming, Catherine; Murphy, Colin G

    2018-04-10

    Prosthetic joint infections (PJIs) are among the most serious complications in arthroplasty. A second-site PJI in patients with multiple prosthetic joints increases morbidity, with many requiring further revision procedures. We aimed to establish why some patients with multiple joints develop second-site infections. Our institution's arthroplasty database was reviewed from 2004 to 2017. All PJIs were identified, and all patients with more than one prosthetic joint in situ were included. We recorded risk factors, causative organisms, number of procedures and length of stay. Forty-four patients meeting the criteria were identified. Four patients (9.1%) developed second-site infection. Eight patients (18.2%) developed re-infection of the primary PJI. Positive MRSA carrier status and PJI of a total knee replacement were associated with an increased risk of a second episode of infection. Patients who developed further infection had more frequent admission and longer lengths of stay than isolated PJIs. Higher morbidity and use of hospital resources are associated with this cohort of patients. PJIs in total knee replacements and positive MRSA status are associated with higher rates of second infection. Identifying this vulnerable cohort of patients at an early stage is critical to ensure measures are taken to reduce the risks of further infection.

  4. Review of Prosthetic Joint Infection from Listeria monocytogenes.

    Science.gov (United States)

    Bader, Gilbert; Al-Tarawneh, Mohammed; Myers, James

    2016-12-01

    Prosthetic joint infection from Listeria monocytogenes is rare. We decided to shed light on this illness and review the reported cases to better understand its characteristics. We conducted a comprehensive review of the English literature using PubMed. We also included one case that we had managed. We found 25 cases of prosthetic joint infection from L. monocytogenes reported individually and a retrospective study of 43 cases of joint and bone listerial infection, including 34 with prosthetic joint infection, conducted in France. We have described their clinical and para-clinical features and tried to elaborate on the pathophysiology, treatment, and prevention. Prosthetic joint infection from L. monocytogenes is mainly late. Systemic inflammation may be absent. Although rare, it must be suspected in patients at high risk for both prosthetic joint and listerial infections. In addition, those patients must be instructed on appropriate preventive measures.

  5. Management of Prosthetic Joint Infection.

    Science.gov (United States)

    Tande, Aaron J; Gomez-Urena, Eric O; Berbari, Elie F; Osmon, Douglas R

    2017-06-01

    Although uncommon, prosthetic joint infection is a devastating complication. This challenging condition requires a coordinated management approach to achieve good patient outcomes. This review details the general principles to consider when managing patients with prosthetic joint infection. The different medical/surgical treatment strategies and how to appropriately select a strategy are discussed. The data to support each strategy are presented, along with discussion of antimicrobial strategies in specific situations. Copyright © 2017 Elsevier Inc. All rights reserved.

  6. Gonococcal Prosthetic Joint Infection.

    Science.gov (United States)

    Gassiep, Ian; Gilpin, Bradley; Douglas, Joel; Siebert, David

    2017-01-01

    Neisseria gonorrhoea is a common sexually transmitted infection worldwide. Disseminated gonococcal infection is an infrequent presentation and rarely can be associated with septic arthritis. Incidence of this infection is rising, both internationally and in older age groups. We present the first documented case of N. gonorrhoea prosthetic joint infection which was successfully treated with laparoscopic debridement and antimicrobial therapy.

  7. Prosthetic Joint Infection

    Science.gov (United States)

    Tande, Aaron J.

    2014-01-01

    SUMMARY Prosthetic joint infection (PJI) is a tremendous burden for individual patients as well as the global health care industry. While a small minority of joint arthroplasties will become infected, appropriate recognition and management are critical to preserve or restore adequate function and prevent excess morbidity. In this review, we describe the reported risk factors for and clinical manifestations of PJI. We discuss the pathogenesis of PJI and the numerous microorganisms that can cause this devastating infection. The recently proposed consensus definitions of PJI and approaches to accurate diagnosis are reviewed in detail. An overview of the treatment and prevention of this challenging condition is provided. PMID:24696437

  8. Prosthetic vascular graft infection and prosthetic joint infection caused by Pseudomonas stutzeri.

    Science.gov (United States)

    Bonares, Michael J; Vaisman, Alon; Sharkawy, Abdu

    2016-01-01

    Pseudomonas stutzeri is infrequently isolated from clinical specimens, and if isolated, more likely represents colonization or contamination rather than infection. Despite this, there are dozens of case reports which describe clinically significant P. stutzeri infections at variable sites. A 69-year-old man had a P. stutzeri infection of a prosthetic vascular graft infection, which he received in Panama City. He was successfully treated with a single antipseudomonal agent for 6 weeks and the removal of the infected vascular graft. A 70-year-old man had a P. stutzeri infection of a prosthetic joint, which was successfully treated with a single anti-pseudomonal agent for 6 weeks. There is only one other documented case of a prosthetic vascular graft infection secondary to P. stutzeri . There are 5 documented cases of P. stutzeri prosthetic joint infections. The previous cases were treated with antibiotics and variably, source control with the removal of prosthetic material. Most cases of P. stutzeri infection are due to exposure in health care settings. Immunocompromised states such as HIV or hematological and solid tumor malignancies are risk factors for P. stutzeri infection. Infections caused by P. stutzeri are far less frequent and less fatal than those caused by P. aeruginosa. The etiology of a P. stutzeri infection could be exposure to soil and water, but also contaminated material in the health care setting or an immunocompromised state. Iatrogenic infections that are secondary to health care tourism are a potential cause of fever in the returned traveler.

  9. Cost analysis of debridement and retention for management of prosthetic joint infection.

    Science.gov (United States)

    Peel, T N; Dowsey, M M; Buising, K L; Liew, D; Choong, P F M

    2013-02-01

    Prosthetic joint infection remains one of the most devastating complications of arthroplasty. Debridement and retention of the prosthesis is an attractive management option in carefully selected patients. Despite this, there are no data investigating the cost of this management modality for prosthetic joint infections. The aim of this case-control study was to calculate the cost associated with debridement and retention for management of prosthetic joint infection compared with primary joint replacement surgery without prosthetic joint infection. From 1 January 2008 to 30 June 2010, there were 21 prosthetic joint infections matched to 42 control patients. Controls were matched to cases according to the arthroplasty site, age and sex. Cases had a greater number of unplanned readmissions (100% vs. 7.1%; p prosthetic joint infection the total cost, including index operation and costs of management of the prosthetic joint infection, was 3.1 times the cost of primary arthoplasty; the mean cost for cases was Australian dollars (AUD) $69,414 (±29,869) compared with $22,085 (±8147) (p prosthetic joint infections will also increase, placing significant burden on the health system. Our study adds significantly to the growing body of evidence highlighting the substantial costs associated with prosthetic joint infection. © 2011 The Authors. Clinical Microbiology and Infection © 2011 European Society of Clinical Microbiology and Infectious Diseases.

  10. Rotationplasty with vascular reconstruction for prosthetic knee joint infection.

    Science.gov (United States)

    Fujiki, Masahide; Miyamoto, Shimpei; Nakatani, Fumihiko; Kawai, Akira; Sakuraba, Minoru

    2015-01-01

    Rotationplasty is used most often as a function-preserving salvage procedure after resection of sarcomas of the lower extremity; however, it is also used after infection of prosthetic knee joints. Conventional vascular management during rotationplasty is to preserve and coil major vessels, but recently, transection and reanastomosis of the major vessels has been widely performed. However, there has been little discussion regarding the optimal vascular management of rotationplasty after infection of prosthetic knee joints because rotationplasty is rarely performed for this indication. We reviewed four patients who had undergone resection of osteosarcomas of the femur, placement of a prosthetic knee joint, and rotationplasty with vascular reconstruction from 2010 to 2013. The mean interval between prosthetic joint replacement and rotationplasty was 10.4 years and the mean interval between the diagnosis of prosthesis infection and rotationplasty was 7.9 years. Rotationplasty was successful in all patients; however, in one patient, arterial thrombosis developed and necessitated urgent surgical removal and arterial reconstruction. All patients were able to walk independently with a prosthetic limb after rehabilitation. Although there is no consensus regarding the most appropriate method of vascular management during rotationplasty for revision of infected prosthetic joints, vascular transection and reanastomosis is a useful option.

  11. Candida infection of a prosthetic shoulder joint

    Energy Technology Data Exchange (ETDEWEB)

    Lichtman, E.A.

    1983-09-01

    A heroin addict developed a Candida parapsilosis infection in a prosthetic shoulder joint. Radiographs showed loose fragments of cement with prosthetic loosening. The patient was treated with removal of the prosthesis and intravenous amphotericin B followed by oral ketoconazole.

  12. Candida infection of a prosthetic shoulder joint

    International Nuclear Information System (INIS)

    Lichtman, E.A.; Veterans Administration Medical Center, New York

    1983-01-01

    A heroin addict developed a Candida parapsilosis infection in a prosthetic shoulder joint. Radiographs showed loose fragments of cement with prosthetic loosening. The patient was treated with removal of the prosthesis and intravenous amphotericin B followed by oral ketoconazole. (orig.)

  13. Granulicatella adiacens prosthetic hip joint infection after dental treatment.

    Science.gov (United States)

    Aweid, Osama; Sundararajan, Sabapathy; Teferi, Abraham

    2016-06-01

    Granulicatella adiacens is a Gram-positive bacteria and a normal component of oral flora. It is also found in dental plaques, endodontic abscesses and can rarely cause more serious infections. We describe a prosthetic hip joint infection in an 81-year-old fit and healthy man due to Granulicatella adiacens who underwent a prolonged dental intervention two days earlier without antibiotic prophylaxis. The infection was successfully treated with surgical intervention and a combination of antibiotics. The patient eventually succumbed to severe community-acquired pneumonia two months later. Current guidelines recommend avoidance of antibiotic prophylaxis prior to dental treatment in patients who have no co-morbidities and no prior operation on the index prosthetic joint. This case report indicates that infections of prosthetic joints may be associated with dental procedures even in fit and healthy patients without the recognized risk factors.

  14. Anaerobic prosthetic joint infection.

    Science.gov (United States)

    Shah, Neel B; Tande, Aaron J; Patel, Robin; Berbari, Elie F

    2015-12-01

    In an effort to improve mobility and alleviate pain from degenerative and connective tissue joint disease, an increasing number of individuals are undergoing prosthetic joint replacement in the United States. Joint replacement is a highly effective intervention, resulting in improved quality of life and increased independence [1]. By 2030, it is predicted that approximately 4 million total hip and knee arthroplasties will be performed yearly in the United States [2]. One of the major complications associated with this procedure is prosthetic joint infection (PJI), occurring at a rate of 1-2% [3-7]. In 2011, the Musculoskeletal Infectious Society created a unifying definition for prosthetic joint infection [8]. The following year, the Infectious Disease Society of America published practice guidelines that focused on the diagnosis and management of PJI. These guidelines focused on the management of commonly encountered organisms associated with PJI, including staphylococci, streptococci and select aerobic Gram-negative bacteria. However, with the exception of Propionibacterium acnes, management of other anaerobic organisms was not addressed in these guidelines [1]. Although making up approximately 3-6% of PJI [9,10], anaerobic microorganisms cause devastating complications, and similar to the more common organisms associated with PJI, these bacteria also result in significant morbidity, poor outcomes and increased health-care costs. Data on diagnosis and management of anaerobic PJI is mostly derived from case reports, along with a few cohort studies [3]. There is a paucity of published data outlining factors associated with risks, diagnosis and management of anaerobic PJI. We therefore reviewed available literature on anaerobic PJI by systematically searching the PubMed database, and collected data from secondary searches to determine information on pathogenesis, demographic data, clinical features, diagnosis and management. We focused our search on five commonly

  15. LEUKOCYTE AND BACTERIA IMAGING IN PROSTHETIC JOINT INFECTION

    NARCIS (Netherlands)

    Glaudemans, Andor W. J. M.; Galli, Filippo; Pacilio, Marta; Signore, Alberto

    2013-01-01

    There has been a significant increase in the number of joint prosthesis replacements worldwide. Although relatively uncommon, complications can occur with the most serious being an infection. Various radiological and nuclear imaging techniques are available to diagnose prosthetic joint infections

  16. Clinical characteristics, microbiology, and outcomes of prosthetic joint infection in Taiwan.

    Science.gov (United States)

    Tsai, Jen-Chih; Sheng, Wang-Huei; Lo, Wan-Yu; Jiang, Ching-Chuan; Chang, Shan-Chwen

    2015-04-01

    Prosthetic joint infection (PJI) after total knee or hip replacement is a devastating complication associated with substantial morbidity and economic cost. The incidence of prosthetic joint infection is increasing as the use of mechanical joint replacement increases. The treatment approach to prosthetic joint infection is based on different clinical situations such as a patient's comorbidities, epidemic microbiology data, and surgical procedures. The aim of our study was to understand clinical characteristics of prosthetic joint infection, the microbiology of the prosthetic joint infection, and the outcomes of different treatment strategies during 2006-2011. We retrospectively collected cases of prosthetic joint infection in the National Taiwan University Hospital between January 1, 2006 and December 31, 2011. The patients' characteristics, microbiology, outcomes, and factors associated with treatment success were recorded. One hundred and forty-four patients were identified as having PJI. Of these, 92 patients were entered into per-protocol analysis. Staphylococcus aureus was the most common causative organism (29.9%), followed by coagulase-negative Staphylococci (16.7%), and Enterococci (9.7%). The overall treatment success rate was 50%. Patients who received a two-stage revision had a better outcome, compared to patients who underwent other types of surgeries (70% vs. 32.7%, respectively; p < 0.001). In multivariate analysis, the two-stage revision was significantly associated with treatment success (odds ratio = 3.923, 95% confidence interval = 1.53-10.04). Our study demonstrates that Staphylococcus aureus was the most common causative organisms in PJI. Performing two-stage revisions was significantly associated with a better outcome. Copyright © 2013. Published by Elsevier B.V.

  17. Clinical Presentation, Risk Factors, and Outcomes of Hematogenous Prosthetic Joint Infection in Patients with Staphylococcus aureus Bacteremia.

    Science.gov (United States)

    Tande, Aaron J; Palraj, Bharath Raj; Osmon, Douglas R; Berbari, Elie F; Baddour, Larry M; Lohse, Christine M; Steckelberg, James M; Wilson, Walter R; Sohail, M Rizwan

    2016-02-01

    Staphylococcus aureus bacteremia is a life-threatening condition that may lead to metastatic infection, including prosthetic joint infection. To assess clinical factors associated with hematogenous prosthetic joint infection, we retrospectively reviewed all patients with a joint arthroplasty in place at the time of a first episode of S. aureus bacteremia over a 5-year period at our institution. Patients with postsurgical prosthetic joint infection without hematogenous prosthetic joint infection were excluded. There were 85 patients (143 arthroplasties) with either no prosthetic joint infection (n = 50; 58.8%) or hematogenous prosthetic joint infection in at least one arthroplasty (n = 35; 41.2%). The odds of hematogenous prosthetic joint infection was significantly increased among patients with community-acquired S. aureus bacteremia (odds ratio [OR] 18.07; 95% confidence interval [CI] 2.64-infinity; P = .001), as compared with nosocomial S. aureus bacteremia, in which there were no patients with hematogenous prosthetic joint infection. After adjusting for S. aureus bacteremia classification, the presence of ≥3 joint arthroplasties in place was associated with a nearly ninefold increased odds of hematogenous prosthetic joint infection as compared with those with 1-2 joint arthroplasties in place (OR 8.55; 95% CI 1.44-95.71; P = .012). All but one joint with prosthetic joint infection demonstrated at least one clinical feature suggestive of infection. There were 4 additional S. aureus prosthetic joint infections diagnosed during a median of 3.4 years of follow-up post hospitalization for S. aureus bacteremia. Prosthetic joint infection is frequent in patients with existing arthroplasties and concomitant S. aureus bacteremia, particularly with community-acquired S. aureus bacteremia and multiple prostheses. In contrast, occult S. aureus prosthetic joint infection without clinical features suggestive of prosthetic joint infection at the time of S. aureus bacteremia

  18. Future Research Opportunities in Peri-Prosthetic Joint Infection Prevention.

    Science.gov (United States)

    Berbari, Elie; Segreti, John; Parvizi, Javad; Berríos-Torres, Sandra I

    Peri-prosthetic joint infection (PJI) is a serious complication of prosthetic joint arthroplasty. A better understanding and reversal of modifiable risk factors may lead to a reduction in the incidence of incisional (superficial and deep) and organ/space (e.g., PJI) surgical site infections (SSI). Recently, the Centers for Disease Control and Prevention (CDC) and the Healthcare Infection Control Practices Advisory Committee (HICPAC) published the Guideline for Prevention of Surgical Site Infection. This targeted update applies evidence-based methodology in drafting recommendations for potential strategies to reduce the risk of SSI both across surgical procedures and specifically in prosthetic joint arthroplasty. A panel of PJI content experts identified nine PJI prevention research opportunities based on both evidence gaps identified through the guideline development process (transfusion, immunosuppressive therapy, anticoagulation, orthopedic space suit, and biofilm) and expert opinion (anesthesia, operative room environment, glycemic control, and Staphylococcus aureus nasal screening and decolonization. This article offers a road map for PJI prevention research.

  19. Pseudotumor of the Hip due to Fungal Prosthetic Joint Infection

    Directory of Open Access Journals (Sweden)

    Stefano Artiaco

    2013-01-01

    Full Text Available Pseudotumors associated with total hip arthroplasty have been associated with metal-on-metal and metal-on-polyethylene total hip arthroplasties due to a granulomatous foreign-body reaction to methyl methacrylate, polyethylene, or metal ion release, but they have not been related to prosthetic joint infections. In this paper, we report an unusual case of Candida albicans total hip arthroplasty infection, causing a large inflammatory pseudotumor of the hip joint. Fungal periprosthetic joint infections are a rare clinical entity and difficult to diagnose, and a pseudotumor may be part of their clinical presentation. They should be suspected in immunodeficient host patients when clinical symptoms of prosthetic joint infections are observed.

  20. Factors influencing the cost of prosthetic joint infection treatment.

    Science.gov (United States)

    Peel, T N; Cheng, A C; Lorenzo, Y P; Kong, D C M; Buising, K L; Choong, P F M

    2013-11-01

    Prosthetic joint infection (PJI) is associated with significant costs to the healthcare system. Current literature examines the cost of specific treatment modalities without assessing other cost drivers for PJI. To examine the overall cost of the treatment of PJI and to identify factors associated with management costs. The costs of treatment of prosthetic joint infections were examined in 139 patients across 10 hospitals over a 3-year period (January 2006 to December 2008). Cost calculations included hospitalization costs, surgical costs, hospital-in-the-home costs and antibiotic therapy costs. Negative binomial regression analysis was performed to model factors associated with total cost. The median cost of treating prosthetic joint infection per patient was Australian $34,800 (interquartile range: 20,305, 56,929). The following factors were associated with increased treatment costs: septic revision arthroplasty (67% increase in treatment cost; P = 0.02), hypotension at presentation (70% increase; P = 0.03), polymicrobial infections (41% increase; P = 0.009), surgical treatment with one-stage exchange (100% increase; P = 0.002) or resection arthroplasty (48% increase; P = 0.001) were independently associated with increased treatment costs. Culture-negative prosthetic joint infections were associated with decreased costs (29% decrease in treatment cost; P = 0.047). Treatment failure was associated with 156% increase in treatment costs. This study identifies clinically important factors influencing treatment costs that may be of relevance to policy-makers, particularly in the setting of hospital reimbursement and guiding future research into cost-effective preventive strategies. Copyright © 2013 The Healthcare Infection Society. Published by Elsevier Ltd. All rights reserved.

  1. Increased risk of prosthetic joint infection associated with esophago-gastro-duodenoscopy with biopsy.

    Science.gov (United States)

    Coelho-Prabhu, Nayantara; Oxentenko, Amy S; Osmon, Douglas R; Baron, Todd H; Hanssen, Arlen D; Wilson, Walter R; Steckelberg, James M; Baddour, Larry M; Harmsen, William S; Mandrekar, Jay; Berbari, Elie F

    2013-02-01

    There are no prospective data regarding the risk of prosthetic joint infection following routine gastrointestinal endoscopic procedures. We wanted to determine the risk of prosthetic hip or knee infection following gastrointestinal endoscopic procedures in patients with joint arthroplasty. We conducted a prospective, single-center, case-control study at a single, tertiary-care referral center. Cases were defined as adult patients hospitalized for prosthetic joint infection of the hip or knee between December 1, 2001 and May 31, 2006. Controls were adult patients with hip or knee arthroplasties but without a diagnosis of joint infection, hospitalized during the same time period at the same orthopedic hospital. The main outcome measure was the odds ratio (OR) of prosthetic joint infection after gastrointestinal endoscopic procedures performed within 2 years before admission. 339 cases and 339 controls were included in the study. Of these, 70 cases (21%) cases and 82 controls (24%) had undergone a gastrointestinal endoscopic procedure in the preceding 2 years. Among gastrointestinal procedures that were assessed, esophago-gastro-duodenoscopy (EGD) with biopsy was associated with an increased risk of prosthetic joint infection (OR = 3, 95% CI: 1.1-7). In a multivariable analysis adjusting for sex, age, joint age, immunosuppression, BMI, presence of wound drain, prior arthroplasty, malignancy, ASA score, and prothrombin time, the OR for infection after EGD with biopsy was 4 (95% CI: 1.5-10). EGD with biopsy was associated with an increased risk of prosthetic joint infection in patients with hip or knee arthroplasties. This association will need to be confirmed in other epidemiological studies and adequately powered prospective clinical trials prior to recommending antibiotic prophylaxis in these patients.

  2. Diagnostic flowcharts in osteomyelitis, spondylodiscitis and prosthetic joint infection

    International Nuclear Information System (INIS)

    Jutte, P.; Lazzeri, E.; Sconfienza, L. M.; Cassar-Pullicino, V.; Trampuz, A.; Petrosillo, N.; Signore, A.

    2014-01-01

    Infections of the bone, spine and prosthetic joints are serious and complex conditions to diagnose and to treat. Structured diagnostic workup may very well improve the accuracy and speed of diagnosis, thereby improving the outcome since treatment may very well be more successful and less harmful if timely management is started. Literature shows no uniform advise on diagnosis. The EANM organized a consensus meeting with representatives from the involved disciplines in order to develop common flowcharts for the diagnosis of osteomyelitis, spondylodiscitis and prosthetic joint infections. In this report the proceedings of this consensus meeting, including the proposed flowcharts for diagnosis, are published.

  3. Prosthetic hip joint infection due to Campylobacter fetus.

    OpenAIRE

    Bates, C J; Clarke, T C; Spencer, R C

    1994-01-01

    A case of postoperative prosthetic hip joint infection due to Campylobacter fetus subsp. fetus is described. Difficulties in isolation and antimicrobial susceptibility testing of this organism are discussed.

  4. Remote transient Lactobacillus animalis bacteremia causing prosthetic hip joint infection: a case report.

    Science.gov (United States)

    Somayaji, R; Lynch, T; Powell, J N; Gregson, D

    2016-11-04

    Lactobacillus spp. are uncommon pathogens in immunocompetent hosts, and even rarer causes of prosthetic device infections. A case of chronic hip prosthetic joint infection (PJI) caused by L. animalis is described. This occurred 5 years after a transient bacteremia with the same organism. Whole genome sequencing of both isolates proved this PJI infection resulted from this remote bacteremia. We document that prosthetic joint infections may be a consequence of bacteremia as much as 3 years before the onset of symptoms.

  5. Acinetobacter Prosthetic Joint Infection Treated with Debridement and High-Dose Tigecycline.

    Science.gov (United States)

    Vila, Andrea; Pagella, Hugo; Amadio, Claudio; Leiva, Alejandro

    2016-12-01

    Prosthesis retention is not recommended for multidrug-resistant Acinetobacter prosthetic joint infection due to its high failure rate. Nevertheless, replacing the prosthesis implies high morbidity and prolonged hospitalization. Although tigecycline is not approved for the treatment of prosthetic joint infection due to multidrug resistant Acinetobacter baumannii, its appropriate use may preclude prosthesis exchange. Since the area under the curve divided by the minimum inhibitory concentration is the best pharmacodynamic predictor of its efficacy, we used tigecycline at high dose, in order to optimize its efficacy and achieve implant retention in 3 patients who refused prosthesis exchange. All patients with prosthetic joint infections treated at our Institution are prospectively registered in a database. Three patients with early prosthetic joint infection of total hip arthroplasty due to multidrug resistant A. baumannii were treated with debridement, antibiotics and implant retention, using a high maintenance dose of tigecycline (100 mg every 12 hours). The cases were retrospectively reviewed. All patients signed informed consent for receiving off-label use of tigecycline. Tigecycline was well tolerated, allowing its administration at high maintenance dose for a median of 40 days (range 30-60). Two patients were then switched to minocycline at standard doses for a median of 3.3 months in order to complete treatment. Currently, none of the patients showed relapse. Increasing the dose of tigecycline could be considered as a means to better attain pharmacodynamic targets in patients with severe or difficult-to-treat infections. Tigecycline at high maintenance dose might be useful when retention of the implant is attempted for treatment for prosthetic joint infections due to multidrug resistant Acinetobacter. Although this approach might be promising, off-label use of tigecycline should be interpreted cautiously until prospective data are available. Tigecycline is

  6. Body mass and weight thresholds for increased prosthetic joint infection rates after primary total joint arthroplasty.

    Science.gov (United States)

    Lübbeke, Anne; Zingg, Matthieu; Vu, Diemlan; Miozzari, Hermes H; Christofilopoulos, Panayiotis; Uçkay, Ilker; Harbarth, Stephan; Hoffmeyer, Pierre

    2016-01-01

    Obesity increases the risk of deep infection after total joint arthroplasty (TJA). Our objective was to determine whether there may be body mass index (BMI) and weight thresholds indicating a higher prosthetic joint infection rate. We included all 9,061 primary hip and knee arthroplasties (mean age 70 years, 61% women) performed between March 1996 and December 2013 where the patient had received intravenous cefuroxime (1.5 g) perioperatively. The main exposures of interest were BMI (5 categories: prosthetic joint infection. The mean follow-up time was 6.5 years (0.5-18 years). 111 prosthetic joint infections were observed: 68 postoperative, 16 hematogenous, and 27 of undetermined cause. Incidence rates were similar in the first 3 BMI categories (infection from the early postoperative period onward (adjusted HR = 2.1, 95% CI: 1.3-3.6). BMI ≥ 35 or weight ≥ 100 kg may serve as a cutoff for higher perioperative dosage of antibiotics.

  7. Remote transient Lactobacillus animalis bacteremia causing prosthetic hip joint infection: a case report

    Directory of Open Access Journals (Sweden)

    R. Somayaji

    2016-11-01

    Full Text Available Abstract Background Lactobacillus spp. are uncommon pathogens in immunocompetent hosts, and even rarer causes of prosthetic device infections. Case presentation A case of chronic hip prosthetic joint infection (PJI caused by L. animalis is described. This occurred 5 years after a transient bacteremia with the same organism. Whole genome sequencing of both isolates proved this PJI infection resulted from this remote bacteremia. Conclusions We document that prosthetic joint infections may be a consequence of bacteremia as much as 3 years before the onset of symptoms.

  8. Rapidly growing non-tuberculous mycobacteria infection of prosthetic knee joints: A report of two cases.

    Science.gov (United States)

    Kim, Manyoung; Ha, Chul-Won; Jang, Jae Won; Park, Yong-Beom

    2017-08-01

    Non-tuberculous mycobacteria (NTM) cause prosthetic knee joint infections in rare cases. Infections with rapidly growing non-tuberculous mycobacteria (RGNTM) are difficult to treat due to their aggressive clinical behavior and resistance to antibiotics. Infections of a prosthetic knee joint by RGNTM have rarely been reported. A standard of treatment has not yet been established because of the rarity of the condition. In previous reports, diagnoses of RGNTM infections in prosthetic knee joints took a long time to reach because the condition was not suspected, due to its rarity. In addition, it is difficult to identify RGNTM in the lab because special identification tests are needed. In previous reports, after treatment for RGNTM prosthetic infections, knee prostheses could not be re-implanted in all cases but one, resulting in arthrodesis or resection arthroplasty; this was most likely due to the aggressiveness of these organisms. In the present report, two cases of prosthetic knee joint infection caused by RGNTM (Mycobacterium abscessus) are described that were successfully treated, and in which prosthetic joints were finally reimplanted in two-stage revision surgery. Copyright © 2017 Elsevier B.V. All rights reserved.

  9. Good quality of life outcomes after treatment of prosthetic joint infection with debridement and prosthesis retention.

    Science.gov (United States)

    Aboltins, Craig; Dowsey, Michelle; Peel, Trish; Lim, Wen K; Choong, Peter

    2016-05-01

    Patients treated for early prosthetic joint infection (PJI) with surgical debridement and prosthesis retention have a rate of successful infection eradication that is similar to patients treated with the traditional approach of prosthesis exchange. It is therefore important to consider other outcomes after prosthetic joint infection treatment that may influence management decisions, such as quality of life (QOL). Our aim was to describe infection cure rates and quality of life for patients with prosthetic joint infection treated with debridement and prosthesis retention and to determine if treatment with this approach was a risk factor for poor quality of life outcomes. Prospectively collected pre and post-arthroplasty data were available for 2,134 patients, of which PJI occurred in 41. For patients treated for prosthetic joint infection, the 2-year survival free of treatment failure was 87% (95%CI 84-89). Prosthetic joint infection cases treated with debridement and retention had a similar improvement from pre-arthroplasty to 12-months post-arthroplasty as patients without PJI in QOL according to the SF-12 survey. Prosthetic joint infection treated with debridement and retention was not a risk factor for poor quality of life on univariate or multivariate analysis. Prosthetic joint infection treated with debridement and prosthesis retention results in good cure rates and quality of life. Further studies are required that directly compare quality of life for different surgical approaches for prosthetic joint infection to better inform management decisions. © 2015 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 34:898-902, 2016. © 2015 Orthopaedic Research Society. Published by Wiley Periodicals, Inc.

  10. Prosthetic joint infection caused by Pasteurella multocida: a case series and review of literature.

    Science.gov (United States)

    Honnorat, Estelle; Seng, Piseth; Savini, Hélène; Pinelli, Pierre-Olivier; Simon, Fabrice; Stein, Andreas

    2016-08-20

    Pasteurella multocida is a well-recognized zoonotic agent following dog or cat bites or scratches. Nevertheless, prosthetic joint infection caused by P. multocida are rarely reported. We report here a series of six cases of prosthetic joint infection caused by P. multocida managed at a referral centre for the treatment of bone and joint infection in southern France. We also reviewed the 26 cases reported in literature. The mean age of our cases was 74 years [±8.2, range 63-85]. In majority of our cases (5 cases) were associated with knee prostheses and one case with a hip prosthesis. Most of cases occurred after cat or dog scratches or licks or contact. Diagnoses of prosthetic joint infection caused by P. multocida were made by positive cultures of surgical biopsies or needle aspiration. Mean time delay between prosthetic joint implantation and infection onset was 7.6 years (±5.12 years, range 2-17). Local inflammation, which occurred in all six cases, was the most frequent clinical symptom, followed by pain in five cases, fever and swollen joints in four cases, and a fistula with purulent discharge inside the wound in two cases. The mean time of antibiotic therapy was 8 months. Surgical treatment with prosthesis removal was performed in three cases. Six of our cases were in remission without apparent relapse at 3 years after end of treatment. Prosthetic joint infections caused by P. multocida usually occur after animal scratches or bites, but can occasionally occur after a short animal lick. These infections are usually resulting from a contiguous infection and localized in the knee. An early antibiotic therapy after surgical debridement could avoid prosthetic withdrawal, notably in elderly patients. Patients with prosthetic joints should be warned that animals are potential sources of serious infection and urgent medical advice should be sought if they are bitten or scratched.

  11. Prosthetic joint infection caused by Granulicatella adiacens: a case series and review of literature.

    Science.gov (United States)

    Quénard, Fanny; Seng, Piseth; Lagier, Jean-Christophe; Fenollar, Florence; Stein, Andreas

    2017-06-23

    Bone and joint infection involving Granulicatella adiacens is rare, and mainly involved in cases of bacteremia and infectious endocarditis. Here we report three cases of prosthetic joint infection involving G. adiacens that were successfully treated with surgery and prolonged antimicrobial treatment. We also review the two cases of prosthetic joint infection involving G. adiacens that are reported in the literature. Not all five cases of prosthetic joint infection caused by G. adiacens were associated with bacteremia or infectious endocarditis. Dental care before the onset of infection was observed in two cases. The median time delay between arthroplasty implantation and the onset of infection was of 4 years (ranging between 2 and 10 years). One of our cases was identified with 16srRNA gene sequencing, one case with MALDI-TOF mass spectrometry, and one case with both techniques. Two literature cases were diagnosed by 16srRNA gene sequencing. All five cases were cured after surgery including a two-stage prosthesis exchange in three cases, a one-stage prosthesis exchange in one case, and debridement, antibiotics, irrigation, and retention of the prosthesis in one case, and prolonged antimicrobial treatment. Prosthetic joint infection involving G. adiacens is probably often dismissed due to difficult culture or misdiagnosis, in particular in the cases of polymicrobial infection. Debridement, antibiotics, irrigation, and retention of the prosthesis associated with prolonged antimicrobial treatment (≥ 8 weeks) should be considered as a treatment strategy for prosthetic joint infection involving G. adiacens.

  12. Pre-operative Asymptomatic Bacteriuria: A Risk Factor For Prosthetic Joint Infection?

    Science.gov (United States)

    Weale, R; El-Bakri, F; Saeed, Kordo

    2018-04-13

    Infection is a rare complication following implantation of prosthetic material into a joint. The impact of asymptomatic bacteriuria (ASB) before elective operations and the subsequent risk of prosthetic joint infection (PJI) are not well understood. • Assess the prevalence of ASB amongst patients undergoing total arthroplasty of the hip and knee. • Determine the rates of PJI diagnosed within two years of the arthroplasty and if ASB is an independent risk factor for developing PJI. Patients who had total/unicondylar knee or total hip arthroplasty were retrospectively reviewed over a five-year period. Pre-operative urine samples within one year of surgery were analysed and those with ASB identified. Primary outcome was prosthetic joint infection (PJI) within the first postoperative year. 5542 patients were included. 4368 had a pre-operative urine culture recorded. The prevalence of ASB was 140 of 4368 (3.2%). The overall PJI rate was 56 of 5542 (1.01%). Of those with a PJI, 33 had a pre-operative urine sample recorded. The infection rate in the ASB group was 5% (7 of 140), in the no-ASB group it was 0.61% (26 of 4228) and in the group without a urine sample it was 1.96% (23 of 1174) (p value prosthetic joint, suggestive the relationship is unlikely causal. Copyright © 2018. Published by Elsevier Ltd.

  13. Leukocyte and bacteria imaging in prosthetic joint infection

    Directory of Open Access Journals (Sweden)

    AWJM Glaudemans

    2013-01-01

    Full Text Available There has been a significant increase in the number of joint prosthesis replacements worldwide. Although relatively uncommon, complications can occur with the most serious being an infection. Various radiological and nuclear imaging techniques are available to diagnose prosthetic joint infections (PJI. In this review article, we describe the pathophysiology of PJI, the principles of nuclear medicine imaging and the differences between Single Photon Emission Computed Tomography (SPECT and Positron Emission Tomography (PET. The value of nuclear medicine techniques for clinical practice is also discussed.Then we provide an overview of the most often used radionuclide imaging techniques that may be helpful in diagnosing prosthetic joint infection: the 67Ga-citrate, labelled white blood cells in vitro and in vivo (monoclonal antibodies directed against specific targets on the leukocytes, and 18F-fluorodeoxyglucose (18F-FDG. We describe their working methods, the pitfalls, and the interpretation criteria. Furthermore, we review recent advances in imaging bacteria, a molecular imaging method that holds promises for the detection of occult infections. We conclude proposing two diagnostic flow-charts, based on data in the literature, that could help the clinicians to choose the best nuclear imaging method when they have a patient with suspicion of or with proven PJI.

  14. Multi-Disciplinary Antimicrobial Strategies for Improving Orthopaedic Implants to Prevent Prosthetic Joint Infections in Hip and Knee

    Science.gov (United States)

    Getzlaf, Matthew A.; Lewallen, Eric A.; Kremers, Hilal M.; Jones, Dakota L.; Bonin, Carolina A.; Dudakovic, Amel; Thaler, Roman; Cohen, Robert C.; Lewallen, David G.; van Wijnen, Andre J.

    2016-01-01

    Like any foreign object, orthopaedic implants are susceptible to infection when introduced into the human body. Without additional preventative measures, the absolute number of annual prosthetic joint infections will continue to rise, and may exceed the capacity of health care systems in the near future. Bacteria are difficult to eradicate from synovial joints due to their exceptionally diverse taxonomy, complex mechanistic attachment capabilities, and tendency to evolve antibiotic resistance. When a primary orthopaedic implant fails from prosthetic joint infection, surgeons are generally challenged by limited options for intervention. In this review, we highlight the etiology and taxonomic groupings of bacteria known to cause prosthetic joint infections, and examine their key mechanisms of attachment. We propose that antimicrobial strategies should focus on the most harmful bacteria taxa within the context of occurrence, taxonomic diversity, adhesion mechanisms, and implant design. Patient-specific identification of organisms that cause prosthetic joint infections will permit assessment of their biological vulnerabilities. The latter can be targeted using a range of antimicrobial techniques that exploit different colonization mechanisms including implant surface attachment, biofilm formation, and/or hematogenous recruitment. We anticipate that customized strategies for each patient, joint, and prosthetic component will be most effective at reducing prosthetic joint infections, including those caused by antibiotic-resistant and polymicrobial bacteria. PMID:26449208

  15. [Microbiological characteristics and patterns of resistance in prosthetic joint infections in a referral hospital].

    Science.gov (United States)

    Ortega-Peña, Silvestre; Colín-Castro, Claudia; Hernández-Duran, Melissa; López-Jácome, Esaú; Franco-Cendejas, Rafael

    2015-01-01

    The prosthetic joint infection is the most feared and catastrophic complication for cause severe physical damage to patients and, generates high economic costs. To describe the microbiological characteristics and to determine the resistance pattern in prosthetic joint infections in a reference hospital in Mexico. Patients whose prosthetic devices were withdrawn due to suspicion of septic and aseptic loosening were included. Cultures were performed to identify microorganisms and susceptibility analysis. Of the 111 patients included, 55% were diagnosed with prosthetic joint infection, with the most frequent prosthesis being of the hip (43%). Positive cultures were obtained in 97% of the infected cases, of which 75% were monomicrobial infections. The most frequent bacterial species isolated were: Staphylococcus epidermidis (31%), Enterococcus faecalis (16%), Staphylococcus aureus (13%), and Escherichia coli (8%). The resistance patterns for the Staphylococcus genus were: oxacillin (79%), erythromycin (45%) and ciprofloxacin (37%). Enterococcus faecalis showed a high percentage of resistance to erythromycin and clindamycin (86%), and fluoroquinolones (43%). The large majority (86%) of Escherichia coli were extended spectrum beta-lactamases positive, in addition to having high resistance to fluoroquinolones (86%), trimethoprim/sulfamethoxazole (86%) and gentamicin (72%). The microbiological characteristics found in prosthetic joint infections vary according to the hospitals. In this series, a high proportion of coagulase-negative Staphylococci and Enterococcus spp. were found, as well as a high bacterial resistance. Copyright © 2015 Academia Mexicana de Cirugía A.C. Published by Masson Doyma México S.A. All rights reserved.

  16. Prosthetic joint infection: state-of-the-art

    Directory of Open Access Journals (Sweden)

    Boris Sergeyevich Belov

    2013-01-01

    Full Text Available In current clinical practice, joint replacement is one of the progressive and permanently developed surgical treatments in patients with locomotor injury of any genesis. However, the upward trend in the number of replacements is inevitably accompanied by the rising number of patients with periprosthetic joint infection. The polymorphism of its clinical picture and the nonspecificity of diagnostic tests lead to a frequent delay in the diagnosis of prosthetic joint infection (PJI and thus late treatment. This paper gives an update on the etiology, epidemiology, clinical presentation, and diagnosis of PJI. Emphasis is laid on the value of a multimodal approach to PJI treatment Р a combination of surgery and etiotropic antibiotic therapy. The choice of a treatment modality is determined by patient status, comorbidity, and the magnitude and duration of the infectious process.

  17. Candida Prosthetic Joint Infection. A Review of Treatment Methods.

    Science.gov (United States)

    Cobo, Fernando; Rodríguez-Granger, Javier; Sampedro, Antonio; Aliaga-Martínez, Luis; Navarro-Marí, José María

    2017-01-01

    Fungal microorganisms are still a rare cause of bone and joint infections. We report a new case of knee prosthetic joint infection due to Candida albicans in a patient with a previous two-stage right knee arthroplasty for septic arthritis due to S. epidermidis occurred several months ago. Moreover, the treatment in 76 cases of Candida prosthetic joint infection has been discussed. Forty patients were female and mean age at diagnosis was 65.7 (± SD 18) yrs. No risk factors for candidal infection were found in 25 patients. Infection site was the knee in 38 patients and hip in 36; pain was present in 44 patients and swelling in 24. The most frequent species was C. albicans , followed by C. parapsilosis . Eleven patients were only treated with antifungal drugs being the outcome favourable in all of them. Two-stage exchange arthroplasty was performed in 30 patients, and resection arthroplasty in other 30; in three patients one-stage exchange arthroplasty was done. A favourable outcome was found in 58 patients after antifungal plus surgical treatment, in 11 after antifungal treatment alone and in one after surgery alone. The type of treatment is still not clearly defined and an algorithm for treatment in fungal PJI should be established, but various types of surgical procedures may be applied.

  18. Isolated Lactobacillus chronic prosthetic knee infection.

    Science.gov (United States)

    Bennett, David M; Shekhel, Tatyana; Radelet, Matt; Miller, Michael D

    2014-01-01

    Lactobacillus is a gram-positive rod bacteria found primarily in the gastrointestinal and female genital tracts. Prosthetic infections in implants are being increasingly reported. The authors present a case of a 58-year-old patient with Lactobacillus septic prosthetic knee joint infection. To the authors’ knowledge, this is the first reported case of chronic prosthetic knee infection with isolated Lactobacillus species. Lactobacillus has been most commonly implicated with bacteremia and endocarditis and rarely with pneumonia, meningitis, and endovascular infection, and a vast majority of the cases are reported in immunocompromised patients. In the current case, diabetes mellitus, hepatitis, malnutrition, anemia, and liver failure were comorbid conditions, placing the patient at increased risk of infection. The findings suggest that further case series are necessary to establish the significance of Lactobacillus as an etiologic agent in chronic low-virulence, and potentially vancomycin-resistant, prosthetic joint infection. The need also exists for further research aimed at the risk of prosthetic joint infection with oral intake of certain probiotic foods and supplements. The goal of this case report is to bring to light the potential of this organism to be a cause of subtle chronic prosthetic joint infection.

  19. Diagnostic flowcharts in osteomyelitis, spondylodiscitis and prosthetic joint infection

    NARCIS (Netherlands)

    Jutte, P.; Lazzeri, E.; Sconfienza, L. M.; Cassar-Pullicino, V.; Trampuz, A.; Petrosillo, N.; Signore, A.

    Infections of the bone, spine and prosthetic joints are serious and complex conditions to diagnose and to treat. Structured diagnostic workup may very well improve the accuracy and speed of diagnosis, thereby improving the outcome since treatment may very well be more successful and less harmful if

  20. One-year incidence of prosthetic joint infection in total hip arthroplasty

    DEFF Research Database (Denmark)

    Gundtoft, P H; Pedersen, A B; Schønheyder, H C

    2017-01-01

    OBJECTIVE: To examine the trend of Prosthetic Joint Infections (PJI) following primary total hip arthroplasty (THA) and the antimicrobial resistance of the bacteria causing these infections. MATERIALS AND METHODS: We identified a population-based cohort of patients in the Danish Hip Arthroplasty...

  1. Microbiological Aetiology, Epidemiology, and Clinical Profile of Prosthetic Joint Infections: Are Current Antibiotic Prophylaxis Guidelines Effective?

    Science.gov (United States)

    Cheng, Allen C.; Buising, Kirsty L.; Choong, Peter F. M.

    2012-01-01

    Prosthetic joint infections remain a major complication of arthroplasty. At present, local and international guidelines recommend cefazolin as a surgical antibiotic prophylaxis at the time of arthroplasty. This retrospective cohort study conducted across 10 hospitals over a 3-year period (January 2006 to December 2008) investigated the epidemiology and microbiological etiology of prosthetic joint infections. There were 163 cases of prosthetic joint infection identified. From a review of the microbiological culture results, methicillin-resistant Staphylococcus aureus (MRSA) and coagulase-negative staphylococci were isolated in 45% of infections. In addition, polymicrobial infections, particularly those involving Gram-negative bacilli and enterococcal species, were common (36%). The majority (88%) of patients received cefazolin as an antibiotic prophylaxis at the time of arthroplasty. In 63% of patients in this cohort, the microorganisms subsequently obtained were not susceptible to the antibiotic prophylaxis administered. The results of this study highlight the importance of ongoing reviews of the local ecology of prosthetic joint infection, demonstrating that the spectrum of pathogens involved is broad. The results should inform empirical antibiotic therapy. This report also provokes discussion about infection control strategies, including changing surgical antibiotic prophylaxis to a combination of glycopeptide and cefazolin, to reduce the incidence of infections due to methicillin-resistant staphylococci. PMID:22314530

  2. FDG-PET for diagnosing prosthetic joint infection: systematic review and metaanalysis

    Energy Technology Data Exchange (ETDEWEB)

    Kwee, Thomas C. [University Medical Center Utrecht, Department of Radiology, Utrecht (Netherlands); Kwee, Robert M. [University Medical Center Maastricht, Department of Radiology, Maastricht (Netherlands); Alavi, Abass [Hospital of the University of Pennsylvania, Division of Nuclear Medicine, Philadelphia, PA (United States)

    2008-11-15

    The aim of this study was to systematically review and metaanalyze published data on the diagnostic performance of {sup 18}F-fluoro-2-deoxyglucose positron emission tomography (FDG-PET) in detecting prosthetic hip or knee joint infection. A systematic search for relevant studies was performed of the PubMed/MEDLINE and Embase databases. Two reviewers independently assessed the methodological quality of each study. A metaanalysis of the reported sensitivity and specificity of each study was performed. Subgroup analyses were performed if results of individual studies were heterogeneous. The inclusion criteria were met by 11 studies; there was a total sample size of 635 prostheses. Overall, the studies had good methodological quality. Pooled sensitivity and specificity of FDG-PET for the detection of prosthetic hip or knee joint infection were 82.1% (95%CI = 68.0-90.8%) and 86.6% (95%CI = 79.7-91.4%), respectively. Heterogeneity among the results of individual studies was present (I {sup 2} = 68.8%). Diagnostic performance was influenced by type of joint prostheses (hip prostheses vs. knee prostheses) and type of reconstruction method used (filtered back vs. iterative) (p = 0.0164 and p = 0.0235, respectively). In this metaanalysis, overall diagnostic performance of FDG-PET was moderate to high. Caution is warranted, however, because results of individual studies were heterogeneous and could not be fully explored. Future studies should further explore potential causes of heterogeneity and validate the use of FDG-PET for diagnosing prosthetic joint infection. (orig.)

  3. FDG-PET for diagnosing prosthetic joint infection: systematic review and metaanalysis

    International Nuclear Information System (INIS)

    Kwee, Thomas C.; Kwee, Robert M.; Alavi, Abass

    2008-01-01

    The aim of this study was to systematically review and metaanalyze published data on the diagnostic performance of 18 F-fluoro-2-deoxyglucose positron emission tomography (FDG-PET) in detecting prosthetic hip or knee joint infection. A systematic search for relevant studies was performed of the PubMed/MEDLINE and Embase databases. Two reviewers independently assessed the methodological quality of each study. A metaanalysis of the reported sensitivity and specificity of each study was performed. Subgroup analyses were performed if results of individual studies were heterogeneous. The inclusion criteria were met by 11 studies; there was a total sample size of 635 prostheses. Overall, the studies had good methodological quality. Pooled sensitivity and specificity of FDG-PET for the detection of prosthetic hip or knee joint infection were 82.1% (95%CI = 68.0-90.8%) and 86.6% (95%CI = 79.7-91.4%), respectively. Heterogeneity among the results of individual studies was present (I 2 = 68.8%). Diagnostic performance was influenced by type of joint prostheses (hip prostheses vs. knee prostheses) and type of reconstruction method used (filtered back vs. iterative) (p = 0.0164 and p = 0.0235, respectively). In this metaanalysis, overall diagnostic performance of FDG-PET was moderate to high. Caution is warranted, however, because results of individual studies were heterogeneous and could not be fully explored. Future studies should further explore potential causes of heterogeneity and validate the use of FDG-PET for diagnosing prosthetic joint infection. (orig.)

  4. Ureaplasma parvum prosthetic joint infection detected by PCR.

    Science.gov (United States)

    Farrell, John J; Larson, Joshua A; Akeson, Jeffrey W; Lowery, Kristin S; Rounds, Megan A; Sampath, Rangarajan; Bonomo, Robert A; Patel, Robin

    2014-06-01

    We describe the first reported case of Ureaplasma parvum prosthetic joint infection (PJI) detected by PCR. Ureaplasma species do not possess a cell wall and are usually associated with colonization and infection of mucosal surfaces (not prosthetic material). U. parvum is a relatively new species name for certain serovars of Ureaplasma urealyticum, and PCR is useful for species determination. Our patient presented with late infection of his right total knee arthroplasty. Intraoperative fluid and tissue cultures and pre- and postoperative synovial fluid cultures were all negative. To discern the pathogen, we employed PCR coupled with electrospray ionization mass spectrometry (PCR/ESI-MS). Our patient's failure to respond to empirical antimicrobial treatment and our previous experience with PCR/ESI-MS in culture-negative cases of infection prompted us to use this approach over other diagnostic modalities. PCR/ESI-MS detected U. parvum in all samples. U. parvum-specific PCR testing was performed on all synovial fluid samples to confirm the U. parvum detection. Copyright © 2014, American Society for Microbiology. All Rights Reserved.

  5. Efficacy of Antibiotic Suppressive Therapy in Patients with a Prosthetic Joint Infection

    NARCIS (Netherlands)

    Wouthuyzen-Bakker, Marjan; Nijman, Jasperina M; Kampinga, Greetje A; van Assen, Sander; Jutte, Paul C

    2017-01-01

    Introduction: For chronic prosthetic joint infections (PJI), complete removal of the infected prosthesis is necessary in order to cure the infection. Unfortunately, a subgroup of patients is not able to undergo a revision surgery due to high surgical risk. Alternatively, these patients can be

  6. Differential contributions of specimen types, culturing, and 16S rRNA sequencing in diagnosis of prosthetic joint infections

    DEFF Research Database (Denmark)

    Larsen, Lone Heimann; Khalid, Vesal; Xu, Yijuan

    2018-01-01

    Prosthetic joint failure is mainly caused by infection, aseptic failure (AF), and mechanical problems. Infection detection has been improved with modified culture methods and molecular diagnostics. However, comparisons between modified and conventional microbiology methods are difficult due...... to variations in specimen sampling. In this prospective, multidisciplinary study of hip or knee prosthetic failures, we assessed the contributions of different specimen types, extended culture incubations, and 16S rRNA sequencing for diagnosing prosthetic joint infections (PJI). Project specimens included joint...... fluid (JF), bone biopsy specimens (BB), soft-tissue biopsy specimens (STB), and swabs (SW) from the prosthesis, collected in situ, and sonication fluid collected from prosthetic components (PC). Specimens were cultured for 6 (conventional) or 14 days, and 16S rRNA sequencing was performed at study...

  7. Technetium-99m-labeled annexin V imaging for detecting prosthetic joint infection in a rabbit model.

    Science.gov (United States)

    Tang, Cheng; Wang, Feng; Hou, Yanjie; Lu, Shanshan; Tian, Wei; Xu, Yan; Jin, Chengzhe; Wang, Liming

    2015-05-01

    Accurate and timely diagnosis of prosthetic joint infection is essential to initiate early treatment and achieve a favorable outcome. In this study, we used a rabbit model to assess the feasibility of technetium-99m-labeled annexin V for detecting prosthetic joint infection. Right knee arthroplasty was performed on 24 New Zealand rabbits. After surgery, methicillin-susceptible Staphylococcus aureus was intra-articularly injected to create a model of prosthetic joint infection (the infected group, n = 12). Rabbits in the control group were injected with sterile saline (n = 12). Seven and 21 days after surgery, technetium-99m-labeled annexin V imaging was performed in 6 rabbits of each group. Images were acquired 1 and 4 hours after injection of technetium-99m-labeled annexin V (150 MBq). The operated-to-normal-knee activity ratios were calculated for quantitative analysis. Seven days after surgery, increased technetium-99m-labeled annexin V uptake was observed in all cases. However, at 21 days a notable decrease was found in the control group, but not in the infected group. The operated-to-normal-knee activity ratios of the infected group were 1.84 ± 0.29 in the early phase and 2.19 ± 0.34 in the delay phase, both of which were significantly higher than those of the control group (P = 0.03 and P = 0.02). The receiver operator characteristic curve analysis showed that the operated-to-normal-knee activity ratios of the delay phase at 21 days was the best indicator, with an accuracy of 80%. In conclusion, technetium-99m-labeled annexin V imaging could effectively distinguish an infected prosthetic joint from an uninfected prosthetic joint in a rabbit model.

  8. Prosthetic joint infection due to Lysobacter thermophilus diagnosed by 16S rRNA gene sequencing

    OpenAIRE

    B Dhawan; S Sebastian; R Malhotra; A Kapil; D Gautam

    2016-01-01

    We report the first case of prosthetic joint infection caused by Lysobacter thermophilus which was identified by 16S rRNA gene sequencing. Removal of prosthesis followed by antibiotic treatment resulted in good clinical outcome. This case illustrates the use of molecular diagnostics to detect uncommon organisms in suspected prosthetic infections.

  9. Revision for prosthetic joint infection following hip arthroplasty: Evidence from the National Joint Registry.

    Science.gov (United States)

    Lenguerrand, E; Whitehouse, M R; Beswick, A D; Jones, S A; Porter, M L; Blom, A W

    2017-06-01

    We used the National Joint Registry for England, Wales, Northern Ireland and the Isle of Man (NJR) to investigate the risk of revision due to prosthetic joint infection (PJI) for patients undergoing primary and revision hip arthroplasty, the changes in risk over time, and the overall burden created by PJI. We analysed revision total hip arthroplasties (THAs) performed due to a diagnosis of PJI and the linked index procedures recorded in the NJR between 2003 and 2014. The cohort analysed consisted of 623 253 index primary hip arthroplasties, 63 222 index revision hip arthroplasties and 7585 revision THAs performed due to a diagnosis of PJI. The prevalence, cumulative incidence functions and the burden of PJI (total procedures) were calculated. Overall linear trends were investigated with log-linear regression. We demonstrated a prevalence of revision THA due to prosthetic joint infection of 0.4/100 procedures following primary and 1.6/100 procedures following revision hip arthroplasty. The prevalence of revision due to PJI in the three months following primary hip arthroplasty has risen 2.3-fold (95% confidence interval (CI) 1.3 to 4.1) between 2005 and 2013, and 3.0-fold (95% CI 1.1 to 8.5) following revision hip arthroplasty. Over 1000 procedures are performed annually as a consequence of hip PJI, an increase of 2.6-fold between 2005 and 2013. Although the risk of revision due to PJI following hip arthroplasty is low, it is rising and, coupled with the established and further predicted increased incidence of both primary and revision hip arthroplasty, this represents a growing and substantial treatment burden. Cite this article : E. Lenguerrand, M. R. Whitehouse, A. D. Beswick, S. A. Jones, M. L. Porter, A. W. Blom. Revision for prosthetic joint infection following hip arthroplasty: Evidence from the National Joint Registry. Bone Joint Res 2017;6:391-398. DOI: 10.1302/2046-3758.66.BJR-2017-0003.R1. © 2017 Lenguerrand et al.

  10. In vitro activity of ceftaroline against staphylococci from prosthetic joint infection.

    Science.gov (United States)

    Park, Kyung-Hwa; Greenwood-Quaintance, Kerryl E; Patel, Robin

    2016-02-01

    We tested the in vitro activity of ceftaroline by Etest against staphylococci recovered from patients with prosthetic joint infection, including 97 Staphylococcus aureus isolates (36%, oxacillin resistant) and 74 Staphylococcus epidermidis isolates (74%, oxacillin resistant). Ceftaroline inhibited all staphylococci at ≤0.5 μg/mL. The ceftaroline MIC(90/50) values for methicillin-susceptible S. aureus, methicillin-susceptible S. epidermidis, methicillin-resistant S. aureus, and methicillin-resistant S. epidermidis were 0.19/0.125, 0.094/0.047, 0.5/0.38, and 0.38/0.19 μg/mL, respectively. Based on these in vitro findings, ceftaroline should be further evaluated as a potential therapeutic option for the treatment of prosthetic joint infection caused by methicillin-susceptible and methicillin-resistant S. aureus and S. epidermidis. Copyright © 2016 Elsevier Inc. All rights reserved.

  11. Prosthetic joint infection due to Lysobacter thermophilus diagnosed by 16S rRNA gene sequencing

    Directory of Open Access Journals (Sweden)

    B Dhawan

    2016-01-01

    Full Text Available We report the first case of prosthetic joint infection caused by Lysobacter thermophilus which was identified by 16S rRNA gene sequencing. Removal of prosthesis followed by antibiotic treatment resulted in good clinical outcome. This case illustrates the use of molecular diagnostics to detect uncommon organisms in suspected prosthetic infections.

  12. Propionibacterium avidum as an Etiological Agent of Prosthetic Hip Joint Infection.

    Directory of Open Access Journals (Sweden)

    Peter Wildeman

    Full Text Available Propionibacterium acnes is well-established as a possible etiologic agent of prosthetic joint infections (PJIs. Other Propionibacterium spp. have occasionally been described as a cause of PJIs, but this has not previously been the case for P. avidum despite its capacity to form biofilm. We describe two patients with prosthetic hip joint infections caused by P. avidum. Both patients were primarily operated with an anteriorly curved skin incision close to the skin crease of the groin, and both were obese. Initial treatment was performed according to the DAIR procedure (debridement, antibiotics, and implant retention. In case 1, the outcome was successful, but in case 2, a loosening of the cup was present 18 months post debridement. The P. avidum isolate from case 1 and two isolates from case 2 (obtained 18 months apart were selected for whole genome sequencing. The genome of P. avidum obtained from case 1 was approximately 60 kb larger than the genomes of the two isolates of case 2. These latter isolates were clonal with the exception of SNPs in the genome. All three strains possessed the gene cluster encoding exopolysaccharide synthesis. P. avidum has a pathogenic potential and the ability to cause clinically relevant infections, including abscess formation, in the presence of foreign bodies such as prosthetic joint components. Skin incision in close proximity to the groin or deep skin crease, such as the anteriorly curved skin incision approach, might pose a risk of PJIs by P. avidum, especially in obese patients.

  13. Prosthetic joint infection caused by Trueperella bernardiae.

    Science.gov (United States)

    Gilarranz, Raul; Chamizo, Francisco; Horcajada, Iballa; Bordes-Benítez, Ana

    2016-09-01

    Trueperella bernardiae is a Gram-positive coryneform bacilli which role as human pathogen is unknown because it has been usually considered a contaminant. Furthermore its identification by biochemical test was difficult. We describe a prosthetic joint infection in a women who years ago underwent a total knee replacement with superinfection and necrosis of the patellar tendon as major complications. In the sample of synovial fluid collected grew a gram-positive bacilli which was identified by matrix-assisted laser desorption/ionization time-of-flight (MALDI-TOF) as T. bernardiae. The patient was treated with ciprofloxacin and currently preserves the prosthesis without signs of infection. Copyright © 2016 Japanese Society of Chemotherapy and The Japanese Association for Infectious Diseases. Published by Elsevier Ltd. All rights reserved.

  14. Improved Diagnosis of Prosthetic Joint Infection by Culturing Periprosthetic Tissue Specimens in Blood Culture Bottles.

    Science.gov (United States)

    Peel, Trisha N; Dylla, Brenda L; Hughes, John G; Lynch, David T; Greenwood-Quaintance, Kerryl E; Cheng, Allen C; Mandrekar, Jayawant N; Patel, Robin

    2016-01-05

    Despite known low sensitivity, culture of periprosthetic tissue specimens on agars and in broths is routine. Culture of periprosthetic tissue samples in blood culture bottles (BCBs) is potentially more convenient, but it has been evaluated in a limited way and has not been widely adopted. The aim of this study was to compare the sensitivity and specificity of inoculation of periprosthetic tissue specimens into blood culture bottles with standard agar and thioglycolate broth culture, applying Bayesian latent class modeling (LCM) in addition to applying the Infectious Diseases Society of America (IDSA) criteria for prosthetic joint infection. This prospective cohort study was conducted over a 9-month period (August 2013 to April 2014) at the Mayo Clinic, Rochester, MN, and included all consecutive patients undergoing revision arthroplasty. Overall, 369 subjects were studied; 117 (32%) met IDSA criteria for prosthetic joint infection, and 82% had late chronic infection. Applying LCM, inoculation of tissues into BCBs was associated with a 47% improvement in sensitivity compared to the sensitivity of conventional agar and broth cultures (92.1 versus 62.6%, respectively); this magnitude of change was similar when IDSA criteria were applied (60.7 versus 44.4%, respectively; P = 0.003). The time to microorganism detection was shorter with BCBs than with standard media (P Prosthetic joint infections are a devastating complication of arthroplasty surgery. Despite this, current microbiological techniques to detect and diagnose infections are imperfect. This study examined a new approach to diagnosing infections, through the inoculation of tissue samples from around the prosthetic joint into blood culture bottles. This study demonstrated that, compared to current laboratory practices, this new technique increased the detection of infection. These findings are important for patient care to allow timely and accurate diagnosis of infection. Copyright © 2016 Peel et al.

  15. Prosthetic joint infections: radionuclide state-of-the-art imaging

    Energy Technology Data Exchange (ETDEWEB)

    Gemmel, Filip [AZ Alma Campus Sijsele, Department of Nuclear Medicine, Sijsele-Damme (Belgium); Wyngaert, Hans van den [AZ Alma Campus Sijsele, Department of Orthopaedic Surgery, Sijsele-Damme (Belgium); Love, Charito [Albert Einstein College of Medicine of Yeshiva University, Division of Nuclear Medicine and Radiology, Bronx, NY (United States); Welling, M.M. [Leiden University Medical Center, Scientist Molecular Imaging, Department of Radiology, Section of Nuclear Medicine C2-203, Leiden (Netherlands); Gemmel, Paul [Ghent University, The Faculty of Economics and Business Administration, Ghent (Belgium); Palestro, Christopher J. [Hofstra North Shore-Long Island Jewish Health System, Division of Nuclear Medicine and Molecular Imaging, Department of Radiology, Hempstead, NY (United States)

    2012-05-15

    Prosthetic joint replacement surgery is performed with increasing frequency. Overall the incidence of prosthetic joint infection (PJI) and subsequently prosthesis revision failure is estimated to be between 1 and 3%. Differentiating infection from aseptic mechanical loosening, which is the most common cause of prosthetic failure, is especially important because of different types of therapeutic management. Despite a thorough patient history, physical examination, multiple diagnostic tests and complex algorithms, differentiating PJI from aseptic loosening remains challenging. Among imaging modalities, radiographs are neither sensitive nor specific and cross-sectional imaging techniques, such as computed tomography and magnetic resonance imaging, are limited by hardware-induced artefacts. Radionuclide imaging reflects functional rather than anatomical changes and is not hampered by the presence of a metallic joint prosthesis. As a result scintigraphy is currently the modality of choice in the investigation of suspected PJI. Unfortunately, there is no true consensus about the gold standard technique since there are several drawbacks and limitations inherent to each modality. Bone scintigraphy (BS) is sensitive for identifying the failed joint replacement, but cannot differentiate between infection and aseptic loosening. Combined bone/gallium scintigraphy (BS/GS) offers modest improvement over BS alone for diagnosing PJI. However, due to a number of drawbacks, BS/GS has generally been superseded by other techniques but it still may have a role in neutropenic patients. Radiolabelled leucocyte scintigraphy remains the gold standard technique for diagnosing neutrophil-mediated processes. It seems to be that combined in vitro labelled leucocyte/bone marrow scintigraphy (LS/BMS), with an accuracy of about 90%, is currently the imaging modality of choice for diagnosing PJI. There are, however, significant limitations using in vitro labelled leucocytes and considerable effort

  16. Prosthetic joint infections: radionuclide state-of-the-art imaging

    International Nuclear Information System (INIS)

    Gemmel, Filip; Wyngaert, Hans van den; Love, Charito; Welling, M.M.; Gemmel, Paul; Palestro, Christopher J.

    2012-01-01

    Prosthetic joint replacement surgery is performed with increasing frequency. Overall the incidence of prosthetic joint infection (PJI) and subsequently prosthesis revision failure is estimated to be between 1 and 3%. Differentiating infection from aseptic mechanical loosening, which is the most common cause of prosthetic failure, is especially important because of different types of therapeutic management. Despite a thorough patient history, physical examination, multiple diagnostic tests and complex algorithms, differentiating PJI from aseptic loosening remains challenging. Among imaging modalities, radiographs are neither sensitive nor specific and cross-sectional imaging techniques, such as computed tomography and magnetic resonance imaging, are limited by hardware-induced artefacts. Radionuclide imaging reflects functional rather than anatomical changes and is not hampered by the presence of a metallic joint prosthesis. As a result scintigraphy is currently the modality of choice in the investigation of suspected PJI. Unfortunately, there is no true consensus about the gold standard technique since there are several drawbacks and limitations inherent to each modality. Bone scintigraphy (BS) is sensitive for identifying the failed joint replacement, but cannot differentiate between infection and aseptic loosening. Combined bone/gallium scintigraphy (BS/GS) offers modest improvement over BS alone for diagnosing PJI. However, due to a number of drawbacks, BS/GS has generally been superseded by other techniques but it still may have a role in neutropenic patients. Radiolabelled leucocyte scintigraphy remains the gold standard technique for diagnosing neutrophil-mediated processes. It seems to be that combined in vitro labelled leucocyte/bone marrow scintigraphy (LS/BMS), with an accuracy of about 90%, is currently the imaging modality of choice for diagnosing PJI. There are, however, significant limitations using in vitro labelled leucocytes and considerable effort

  17. Vancomycin-Rifampin Combination Therapy Has Enhanced Efficacy against an Experimental Staphylococcus aureus Prosthetic Joint Infection

    Science.gov (United States)

    Niska, Jared A.; Shahbazian, Jonathan H.; Ramos, Romela Irene; Francis, Kevin P.; Bernthal, Nicholas M.

    2013-01-01

    Treatment of prosthetic joint infections often involves a two-stage exchange, with implant removal and antibiotic spacer placement followed by systemic antibiotic therapy and delayed reimplantation. However, if antibiotic therapy can be improved, one-stage exchange or implant retention may be more feasible, thereby decreasing morbidity and preserving function. In this study, a mouse model of prosthetic joint infection was used in which Staphylococcus aureus was inoculated into a knee joint containing a surgically placed metallic implant extending from the femur. This model was used to evaluate whether combination therapy of vancomycin plus rifampin has increased efficacy compared with vancomycin alone against these infections. On postoperative day 7, vancomycin with or without rifampin was administered for 6 weeks with implant retention. In vivo bioluminescence imaging, ex vivo CFU enumeration, X-ray imaging, and histologic analysis were carried out. We found that there was a marked therapeutic benefit when vancomycin was combined with rifampin compared with vancomycin alone. Taken together, our results suggest that the mouse model used could serve as a valuable in vivo preclinical model system to evaluate and compare efficacies of antibiotics and combinatory therapy for prosthetic joint infections before more extensive studies are carried out in human subjects. PMID:23917317

  18. Global changes in Staphylococcus aureus gene expression during human prosthetic joint infection

    DEFF Research Database (Denmark)

    Xu, Yijuan; Nielsen, Per Halkjær; Nielsen, Jeppe Lund

    2016-01-01

    and Environmental Engineering, Aalborg University, Denmark 2: Danish Technological Institute, Aarhus, Denmark Aim: ”The aim of this study was to gain insight into the in vivo expression of virulence and metabolic genes of Staphylococcus aureus in a prosthetic joint infection in a human subject” Method: ”Deep RNA......Global changes in Staphylococcus aureus gene expression during human prosthetic joint infection Xu, Yijuan1; Nielsen, Per H.1; Nielsen, Jeppe L.1; Thomsen, Trine R. 1,2; Nielsen, Kåre L.1 and the PRIS study group 1: Center for Microbial Communities, Department of Biotechnology, Chemistry...... involved overexpression of various enzymes related to cell-wall synthesis and multidrug efflux pumps. Interestingly, these efflux pumps are only known to be related to fluoroquinolone resistance. Many of the genes encoding virulence factors were upregulated, including toxins and superantigen-like proteins...

  19. [Joint Prosthetic Infection: UpDate Approaches to Diagnosis and Treatment].

    Science.gov (United States)

    Belov, B S; Makarov, S A; Byalik, E I

    2015-01-01

    At present endoprosthetics of the joints is considered as a progressive and ever developing method in the surgical treatment of patients with affection of the locomotor system of any genesis. Hence, increasing of the number of endoprosthetic results in increasing of the number of patients with periprosthetic infection. Polymorphism of the clinical picture and inspecificity of the diagnostic tests often cause a delay in the diagnosis of the joint prosthetic infection (JPI) and consequently the late treatment. The contemporary data on the etiology, epidemiology, clinical picture and diagnosis of JPI are presented. The importance of cooperated treatment of JPI, i.e. combination of the surgical management and etiotropic antibacterial therapy is indicated. The choice of the concrete treatment method is defined by the patient state, comorbid pathology, the infection severity and duration.

  20. Is There an Association Between Smoking Status and Prosthetic Joint Infection After Primary Total Joint Arthroplasty?

    Science.gov (United States)

    Gonzalez, Amanda I; Luime, Jolanda J; Uçkay, Ilker; Hannouche, Didier; Hoffmeyer, Pierre; Lübbeke, Anne

    2018-02-23

    Recent reports highlighted the association between smoking and higher risk of postsurgical infections. The aim was to compare the incidence of prosthetic joint infection after primary total joint arthroplasty (TJA) according to smoking status. A prospective hospital registry-based cohort study was performed including all primary knee and hip TJAs performed between March 1996 and December 2013. Smoking status preoperatively was classified into never, former, and current smoker. Incidence rates and hazard ratios (HRs) for prosthetic joint infection according to smoking status were assessed within the first year and beyond. We included 8559 primary TJAs (mean age 69.5 years), and median follow-up was 67 months. There were 5722 never, 1315 former, and 1522 current smokers. Incidence rates of infection within the first year for never, former, and current smokers were, respectively, 4.7, 10.1, and 10.9 cases/1000 person-years, comparing ever vs never smokers, crude and adjusted HRs were 2.35 (95% confidence interval [CI] 1.39-3.98) and 1.8 (95% CI 1.04-3.2). Beyond the first year, crude and adjusted HRs were 1.37 (95% CI 0.78-2.39) and 1.12 (95% CI 0.61-2.04). Smoking increased the infection risk about 1.8 times after primary hip or knee TJA in both current and former smokers. Beyond the first year, the infection risk was similar to never smokers. Copyright © 2018 Elsevier Inc. All rights reserved.

  1. Rapid Molecular Microbiologic Diagnosis of Prosthetic Joint Infection

    Science.gov (United States)

    Cazanave, Charles; Greenwood-Quaintance, Kerryl E.; Hanssen, Arlen D.; Karau, Melissa J.; Schmidt, Suzannah M.; Gomez Urena, Eric O.; Mandrekar, Jayawant N.; Osmon, Douglas R.; Lough, Lindsay E.; Pritt, Bobbi S.; Steckelberg, James M.

    2013-01-01

    We previously showed that culture of samples obtained by prosthesis vortexing and sonication was more sensitive than tissue culture for prosthetic joint infection (PJI) diagnosis. Despite improved sensitivity, culture-negative cases remained; furthermore, culture has a long turnaround time. We designed a genus-/group-specific rapid PCR assay panel targeting PJI bacteria and applied it to samples obtained by vortexing and sonicating explanted hip and knee prostheses, and we compared the results to those with sonicate fluid and periprosthetic tissue culture obtained at revision or resection arthroplasty. We studied 434 subjects with knee (n = 272) or hip (n = 162) prostheses; using a standardized definition, 144 had PJI. Sensitivities of tissue culture, of sonicate fluid culture, and of PCR were 70.1, 72.9, and 77.1%, respectively. Specificities were 97.9, 98.3, and 97.9%, respectively. Sonicate fluid PCR was more sensitive than tissue culture (P = 0.04). PCR of prosthesis sonication samples is more sensitive than tissue culture for the microbiologic diagnosis of prosthetic hip and knee infection and provides same-day PJI diagnosis with definition of microbiology. The high assay specificity suggests that typical PJI bacteria may not cause aseptic implant failure. PMID:23658273

  2. Prosthetic joint infection development of an evidence-based diagnostic algorithm.

    Science.gov (United States)

    Mühlhofer, Heinrich M L; Pohlig, Florian; Kanz, Karl-Georg; Lenze, Ulrich; Lenze, Florian; Toepfer, Andreas; Kelch, Sarah; Harrasser, Norbert; von Eisenhart-Rothe, Rüdiger; Schauwecker, Johannes

    2017-03-09

    Increasing rates of prosthetic joint infection (PJI) have presented challenges for general practitioners, orthopedic surgeons and the health care system in the recent years. The diagnosis of PJI is complex; multiple diagnostic tools are used in the attempt to correctly diagnose PJI. Evidence-based algorithms can help to identify PJI using standardized diagnostic steps. We reviewed relevant publications between 1990 and 2015 using a systematic literature search in MEDLINE and PUBMED. The selected search results were then classified into levels of evidence. The keywords were prosthetic joint infection, biofilm, diagnosis, sonication, antibiotic treatment, implant-associated infection, Staph. aureus, rifampicin, implant retention, pcr, maldi-tof, serology, synovial fluid, c-reactive protein level, total hip arthroplasty (THA), total knee arthroplasty (TKA) and combinations of these terms. From an initial 768 publications, 156 publications were stringently reviewed. Publications with class I-III recommendations (EAST) were considered. We developed an algorithm for the diagnostic approach to display the complex diagnosis of PJI in a clear and logically structured process according to ISO 5807. The evidence-based standardized algorithm combines modern clinical requirements and evidence-based treatment principles. The algorithm provides a detailed transparent standard operating procedure (SOP) for diagnosing PJI. Thus, consistently high, examiner-independent process quality is assured to meet the demands of modern quality management in PJI diagnosis.

  3. Candida-induced prosthetic joint infection. A literature review including 72 cases and a case report.

    Science.gov (United States)

    Cobo, Fernando; Rodríguez-Granger, Javier; López, Enrique M; Jiménez, Gemma; Sampedro, Antonio; Aliaga-Martínez, Luis; Navarro-Marí, José María

    2017-02-01

    The clinical and microbiological characteristics of prosthetic joint infection (PJI) caused by Candida species is described, including 72 cases in the literature and a case of Candida glabrata infection handled at the present centre. We describe one patient and using the key words 'fungal prosthetic joint infection' and 'candida prosthetic joint infection' we searched MEDLINE (National Library of Medicine, Bethesda, MD), Web of Science, CINAHL and Cochrane systematic review databases for case reports of this condition. Out of the 73 patients, 38 were female; mean age at diagnosis was 65.7 (± SD 18) yrs; 50 had risk factors for candidal infection such as systemic disease (e.g. rheumatoid arthritis, Sjogren's syndrome, systemic lupus erythematosus) and/or immunosuppressive therapy in 18 (24.6%) cases, diabetes mellitus in 14 (19.1%), immunosuppression due to malignant or chronic disease in 24 (32.8%) and long-term antibiotic use in four (5.4%) patients. Infection site was the knee in 36 patients and hip in 35; pain was present in 43 patients and swelling in 23 and the mean surgery-diagnosis interval was 32 months. The most frequent species was C. albicans, followed by C. parapsilosis. The diagnosis was obtained from joint fluid aspirate in 33 cases and intra-operative samples in 16. Susceptibility to antifungals was tested in only 21 isolates. The most frequently used antifungals were fluconazole and amphotericin B. Two-stage exchange arthroplasty was performed in 30 patients and resection arthroplasty in 31; 56 patients were cured with a combination of medical and surgical treatment; one patient died from the infection. PJI caused by Candida requires a high index of suspicion; surgery with long-term antifungal therapy is recommended.

  4. Neisseria meningitidis Infecting a Prosthetic Knee Joint: A New Case of an Unusual Disease

    Directory of Open Access Journals (Sweden)

    Berta Becerril Carral

    2017-01-01

    Full Text Available Primary meningococcal meningitis is an infrequent but known disease. However, the infection of a prosthetic joint with Neisseria meningitidis is rare. We hereby describe the second case of an arthroplasty infected with Neisseria meningitidis that responded favourably to prosthesis retention with surgical debridement, in combination with antibiotics treatment.

  5. Actinobaculum schaalii, a new cause of knee prosthetic joint infection in elderly.

    Science.gov (United States)

    Jacquier, H; Benmansour, H; Zadegan, F; Hannouche, D; Micaelo, M; Mongiat-Artus, P; Salomon, E; Cambau, E; Berçot, B

    2016-08-01

    Actinobaculum schaalii is an emerging pathogen particularly involved in urinary tract infection of elderly people and/or patient with urological risk factors of urinary tract infection. This microorganism is a difficult-to-diagnose pathogen and is rarely involved in systemic or deep infections. Here, we report the first case of prosthetic joint infection due to A. schaalii in an 84-year-old man with a benign prostatic hyperplasia associated with chronic retention of urine. This case underlines the importance to optimize the diagnosis of emerging uropathogens as A. schaalii, to prevent systemic infections, particularly in patients with orthopaedic implants.

  6. Evaluation of 99mTc-UBI 29-41 scintigraphy for specific detection of experimental Staphylococcus aureus prosthetic joint infections

    International Nuclear Information System (INIS)

    Sarda-Mantel, Laure; Meulemans, Alain; Vrigneaud, Jean-Marc; Raguin, Olivier; Lebtahi, Rachida; Guludec, Dominique Le; Saleh-Mghir, Azzam; Welling, Mick M.; Hervatin, Florence; Martet, Genevieve; Chau, Francoise

    2007-01-01

    99m Tc-UBI 29-41 (UBI), an antimicrobial peptide, specifically targets bacteria. We tested the ability of UBI to discriminate between infected and uninfected prosthetic joints using a rabbit model previously validated. Left knee arthroplasty was performed on 20 New Zealand rabbits, then 10 7 cfu of S. aureus (n = 12) or sterile saline (n = 8) was injected into the joint. On days 9 and 20 after surgery, planar UBI scintigraphy was performed in six infected and four uninfected rabbits, 1 h and 4 h p.i. (150 MBq), on a gamma camera. Operated-to-normal knee activity ratio (ONKR) was calculated on each scintigram. Then, after sacrifice, tissue samples of both knees were counted in a gamma counter. One rabbit injected with sterile saline had cutaneous infection at sacrifice and was excluded from analysis. ONKR was higher in infected than in uninfected animals 4 h p.i. 20 days after surgery: 1.75 ± 0.48 vs 1.13 ± 0.11, p = 0.04. From 1 h to 4 h p.i., ONKR increased in 9/12 infected and 0/7 uninfected animals. According to UBI uptake intensity and kinetics, scintigraphy was truly positive in all infected cases on day 9 and in four of six infected cases on day 20. It was truly negative in two of three sterile inflamed prosthetic knees on day 9, and in all cases on day 20. Biodistribution studies revealed increased UBI uptake in periprosthetic tissues in all animals 9 days after surgery, and only in infected animals on day 20. In this experimental study, 99m Tc-UBI 29-41 scintigraphy permitted the early detection of acute prosthetic joint infection, and exclusion of infection in chronic sterile prosthetic joint inflammation. (orig.)

  7. Clinical characteristics and outcomes of prosthetic joint infection caused by small colony variant staphylococci.

    Science.gov (United States)

    Tande, Aaron J; Osmon, Douglas R; Greenwood-Quaintance, Kerryl E; Mabry, Tad M; Hanssen, Arlen D; Patel, Robin

    2014-09-30

    Small colony variants (SCVs) are naturally occurring subpopulations of bacteria. The clinical characteristics and treatment outcomes of patients with prosthetic joint infection (PJI) caused by staphylococcal SCVs are unknown. This study was a retrospective series of 113 patients with staphylococcal PJI, with prospective testing of archived sonicate fluid samples. SCVs were defined using two-investigator review. Treatment failure was defined as (i) subsequent revision surgery for any reason, (ii) PJI after the index surgery, (iii) prosthesis nonreimplantation due to ongoing infection, or (iv) amputation of the affected limb. There were 38 subjects (34%) with SCVs and 75 (66%) with only normal-phenotype (NP) bacteria. Subjects with SCVs were more likely to have been on chronic antimicrobials prior to surgery (P = 0.048), have had prior surgery for PJI (P = 0.03), have had a longer duration of symptoms (P = 0.0003), and have had a longer time since joint implantation (P = 0.007), compared to those with only NP bacteria. Over a median follow-up of 30.6 months, 9 subjects (24%) with SCVs and 23 (32%) with only NP bacteria experienced treatment failure (P = 0.51). Subjects infected with Staphylococcus aureus were more likely to fail than were those infected with Staphylococcus epidermidis (hazard ratio [HR], 4.03; 95% confidence interval [CI], 1.80 to 9.04). While frequently identified in subjects with PJI and associated with several potential predisposing factors, SCVs were not associated with excess treatment failure compared to NP infections in this study, where they were primarily managed with two-stage arthroplasty exchange. Bacteria with the small colony variant (SCV) phenotype are described in small case series as causing persistent or relapsing infection, but there are insufficient data to suggest that they should be managed differently than infection with normal-phenotype bacteria. In an effort to investigate the clinical importance of this phenotype, we

  8. Synovial Calprotectin: An Inexpensive Biomarker to Exclude a Chronic Prosthetic Joint Infection.

    Science.gov (United States)

    Wouthuyzen-Bakker, Marjan; Ploegmakers, Joris J W; Ottink, Karsten; Kampinga, Greetje A; Wagenmakers-Huizenga, Lucie; Jutte, Paul C; Kobold, Anneke C M

    2018-04-01

    To diagnose or exclude a chronic prosthetic joint infection (PJI) can be a clinical challenge. Therefore, sensitive and specific biomarkers are needed in the diagnostic work-up. Calprotectin is a protein with antimicrobial properties and is released by activated neutrophils, making it a specific marker for infection. Because of its low costs and ability to obtain a quantitative value as a point of care test, it is an attractive marker to use in clinical practice. In addition, the test is already used in routine care in most hospitals for other indications and therefore easy to implement. Between June 2015 and June 2017 we collected synovial fluid of all consecutive patients who underwent revision surgery of a prosthetic joint because of chronic pain with or without prosthetic loosening. Synovial calprotectin was measured using a lateral flow immunoassay. A PJI was defined by the diagnostic criteria described by the Musculoskeletal Infection Society. Fifty-two patients with chronic pain were included. A PJI was diagnosed in 15 of 52 (29%) patients. The median calprotectin in the PJI group was 859 mg/L (interquartile range 86-1707) vs 7 mg/L (interquartile range 3-25) in the control group (P < .001). With a cut-off value of 50 mg/L, synovial calprotectin showed a sensitivity, specificity, positive predictive value, and negative predictive value of 86.7%, 91.7%, 81.3%, and 94.4%, respectively. Synovial calprotectin is a useful and cheap biomarker to use in the diagnostic work-up of patients with chronic pain, especially to exclude a PJI prior to revision surgery. Copyright © 2017 Elsevier Inc. All rights reserved.

  9. Evaluation of {sup 99m}Tc-UBI 29-41 scintigraphy for specific detection of experimental Staphylococcus aureus prosthetic joint infections

    Energy Technology Data Exchange (ETDEWEB)

    Sarda-Mantel, Laure; Meulemans, Alain; Vrigneaud, Jean-Marc; Raguin, Olivier; Lebtahi, Rachida; Guludec, Dominique Le [Universite Denis Diderot-Paris 7, UMR S773, Paris (France); Service de Medecine Nucleaire, AP-HP, Groupe Hospitalier Bichat-Beaujon, Paris (France); INSERM, U773, Paris (France); Saleh-Mghir, Azzam [Universite Versailles-St-Quentin, EA 3647, Garches (France); Welling, Mick M. [Leiden University Medical Center (LUCM), Department of Radiology, Section of Nuclear Medicine, Leiden (Netherlands); Hervatin, Florence [Universite Denis Diderot-Paris 7, UMR S773, Paris (France); CEA, DSV/DRM/SHFJ, Orsay (France); Martet, Genevieve [Universite Denis Diderot-Paris 7, UMR S773, Paris (France); INSERM, U773, Paris (France); Chau, Francoise [Universite Denis Diderot-Paris 7, UMR S773, Paris (France); Universite Denis Diderot Paris 7, EA 3964, Paris (France)

    2007-08-15

    {sup 99m}Tc-UBI 29-41 (UBI), an antimicrobial peptide, specifically targets bacteria. We tested the ability of UBI to discriminate between infected and uninfected prosthetic joints using a rabbit model previously validated. Left knee arthroplasty was performed on 20 New Zealand rabbits, then 10{sup 7} cfu of S. aureus (n = 12) or sterile saline (n = 8) was injected into the joint. On days 9 and 20 after surgery, planar UBI scintigraphy was performed in six infected and four uninfected rabbits, 1 h and 4 h p.i. (150 MBq), on a gamma camera. Operated-to-normal knee activity ratio (ONKR) was calculated on each scintigram. Then, after sacrifice, tissue samples of both knees were counted in a gamma counter. One rabbit injected with sterile saline had cutaneous infection at sacrifice and was excluded from analysis. ONKR was higher in infected than in uninfected animals 4 h p.i. 20 days after surgery: 1.75 {+-} 0.48 vs 1.13 {+-} 0.11, p = 0.04. From 1 h to 4 h p.i., ONKR increased in 9/12 infected and 0/7 uninfected animals. According to UBI uptake intensity and kinetics, scintigraphy was truly positive in all infected cases on day 9 and in four of six infected cases on day 20. It was truly negative in two of three sterile inflamed prosthetic knees on day 9, and in all cases on day 20. Biodistribution studies revealed increased UBI uptake in periprosthetic tissues in all animals 9 days after surgery, and only in infected animals on day 20. In this experimental study, {sup 99m}Tc-UBI 29-41 scintigraphy permitted the early detection of acute prosthetic joint infection, and exclusion of infection in chronic sterile prosthetic joint inflammation. (orig.)

  10. Indium-granulocyte scanning in the painful prosthetic joint

    International Nuclear Information System (INIS)

    Pring, D.J.; Henderson, R.G.; Keshavarzian, A.; Rivett, A.G.; Krausz, T.; Coombs, R.R.; Lavender, J.P.

    1986-01-01

    The value of indium-111-labeled granulocyte scanning to determine the presence of infection was assessed in 50 prosthetic joints (41 of which were painful) in 40 patients. Granulocytes were obtained from the patients' blood and labeled in plasma with indium 111 tropolonate. Abnormal accumulation of indium 111 in the region of the prosthesis was noted. Proven infection occurred in 11 prostheses, and all of the infections were detected by indium-111-labeled granulocyte scanning. Nineteen were not infected (including nine asymptomatic controls) and only two produced false-positive scans. This represents a specificity of 89.5%, sensitivity of 100%, and overall accuracy of 93.2%. These results compare favorably with plain radiography. There was no radiologic evidence of infection in three of the infected prostheses, and 10 of the noninfected prostheses had some radiologic features that suggested sepsis. We conclude that indium-granulocyte scanning can reliably detect or exclude infection in painful prosthetic joints and should prove useful in clinical management

  11. Periprosthetic Joint Infections: Clinical and Bench Research

    Directory of Open Access Journals (Sweden)

    Laurence Legout

    2013-01-01

    Full Text Available Prosthetic joint infection is a devastating complication with high morbidity and substantial cost. The incidence is low but probably underestimated. Despite a significant basic and clinical research in this field, many questions concerning the definition of prosthetic infection as well the diagnosis and the management of these infections remained unanswered. We review the current literature about the new diagnostic methods, the management and the prevention of prosthetic joint infections.

  12. Candida glabrata prosthetic joint infection, successfully treated with anidulafungin: A case report and review of the literature.

    Science.gov (United States)

    Koutserimpas, Christos; Samonis, George; Velivassakis, Emmanouil; Iliopoulou-Kosmadaki, Stylliani; Kontakis, Georgios; Kofteridis, Diamantis P

    2018-04-01

    Non-albicans Candida prosthetic joint infection (PJI) is extremely rare. A case of a Candida glabrata knee PJI is a 68-year-old splenectomised female smoker, suffering from chronic obstructive pulmonary disease (COPD) and alcoholism is reported. The patient presented with a peri-prosthetic fracture, 15 years after total knee replacement surgery. Cultures of the intraoperative peri-prosthetic tissue and materials yielded C. glabrata, as well as a methicillin-resistant S. epidermitis. The patient was treated with anidulafungin and vancomycin. The knee prosthetic joint was removed and cement-spacer with vancomycin and gentamycin was placed. Additionally, an external fixation was performed. A second stage revision surgery was planned, after completion of the antimicrobial and antifungal treatment. The patient is followed up for 4 months without signs, symptoms or findings of infection. PJI Candida infections require a high clinical suspicion index. It is of utmost importance to report these cases, since there is no consensus yet of the proper antifungal treatment. Furthermore, a literature review regarding treatment of those cases is provided. First-line treatment with an echinocandin seems most proper, due to their fungicidal properties, their effectiveness against biofilm, as well as their minimal toxicity, making them ideal for long-term use. Further experience is needed, for better understanding the disease's pathogenesis and optimal treatment. © 2017 Blackwell Verlag GmbH.

  13. Increasing risk of prosthetic joint infection after total hip arthroplasty

    DEFF Research Database (Denmark)

    Dale, Håvard; Fenstad, Anne M; Hallan, Geir

    2012-01-01

    Background and purpose The risk of revision due to infection after primary total hip arthroplasty (THA) has been reported to be increasing in Norway. We investigated whether this increase is a common feature in the Nordic countries (Denmark, Finland, Norway, and Sweden). Materials and methods The...... explain this increase. We believe that there has been an actual increase in the incidence of prosthetic joint infections after THA.......Background and purpose The risk of revision due to infection after primary total hip arthroplasty (THA) has been reported to be increasing in Norway. We investigated whether this increase is a common feature in the Nordic countries (Denmark, Finland, Norway, and Sweden). Materials and methods...... The study was based on the Nordic Arthroplasty Register Association (NARA) dataset. 432,168 primary THAs from 1995 to 2009 were included (Denmark: 83,853, Finland 78,106, Norway 88,455, and Sweden 181,754). Adjusted survival analyses were performed using Cox regression models with revision due to infection...

  14. Scintigraphic detection of prosthetic joint and soft tissue sepsis secondary to tuberculosis

    International Nuclear Information System (INIS)

    Zeiger, L.S.; Watters, W.; Sherk, H.

    1984-01-01

    In a 40-year-old Hispanic woman with pain and swelling in the left knee with a prosthesis, the combination of Ga-67 citrate and Tc-99m methylene diphosphonate (MDP) scans was used to indicate that there was a septic prosthetic joint. At surgery, the joint was infected and a foreign body was found. Cultures positive for tuberculosis were found also. The presence of an incongruent Ga-67 and Tc-99m (MDP) scan pattern suggests infection of the prosthetic joint, as in the following case

  15. Prosthetic Joint Infection due to Mycobacterium bovis after Intravesical Instillation of Bacillus Calmette-Guerin (BCG

    Directory of Open Access Journals (Sweden)

    Eric Gomez

    2009-01-01

    Full Text Available Intravesical instillation of Bacillus Calmette-Guerin (BCG is a treatment to prevent recurrence of superficial urothelial bladder carcinoma. Complications after bladder instillation of BCG have been reported including locally invasive and systemic infections due to dissemination of Mycobacterium bovis from the bladder. We present an uncommon case and literature review of prosthetic joint infection due to M. bovis after intravesical BCG treatment of bladder cancer.

  16. Human prosthetic joint infections are associated with myeloid-derived suppressor cells (MDSCs): Implications for infection persistence.

    Science.gov (United States)

    Heim, Cortney E; Vidlak, Debbie; Odvody, Jessica; Hartman, Curtis W; Garvin, Kevin L; Kielian, Tammy

    2017-11-15

    Prosthetic joint infection (PJI) is a devastating complication of joint arthroplasty surgery typified by biofilm formation. Currently, mechanisms whereby biofilms persist and evade immune-mediated clearance in immune competent patients remain largely ill-defined. Therefore, the current study characterized leukocyte infiltrates and inflammatory mediator expression in tissues from patients with PJI compared to aseptic loosening. CD33 + HLA-DR - CD66b + CD14 -/low granulocytic myeloid-derived suppressor cells (G-MDSCs) were the predominant leukocyte population at sites of human PJI compared to aseptic tissues. MDSCs inhibit T cell proliferation, which coincided with reduced T cells in PJIs compared to aseptic tissues. IL-10, IL-6, and CXCL1 were significantly elevated in PJI tissues and have been implicated in MDSC inhibitory activity, expansion, and recruitment, respectively, which may account for their preferential increase in PJIs. This bias towards G-MDSC accumulation during human PJI could account for the chronicity of these infections by preventing the pro-inflammatory, antimicrobial actions of immune effector cells. Animal models of PJI have revealed a critical role for MDSCs and IL-10 in promoting infection persistence; however, whether this population is prevalent during human PJI and across distinct bacterial pathogens remains unknown. This study has identified that granulocytic-MDSC infiltrates are unique to human PJIs caused by distinct bacteria, which are not associated with aseptic loosening of prosthetic joints. Better defining the immune status of human PJIs could lead to novel immune-mediated approaches to facilitate PJI clearance in combination with conventional antibiotics. © 2017 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res. © 2017 Orthopaedic Research Society. Published by Wiley Periodicals, Inc.

  17. Ten questions on prosthetic shoulder infection.

    Science.gov (United States)

    Pinder, Elizabeth M; Ong, Joshua Cy; Bale, R Stephen; Trail, Ian A

    2016-07-01

    Prosthetic shoulder infection can cause significant morbidity secondary to pain and stiffness. Symptoms may be present for years before diagnosis because clinical signs are often absent and inflammatory markers may be normal. An emerging common culprit, Propionibacterium acnes, is hard to culture and so prolonged incubation is necessary. A negative culture result does not always exclude infection and new synovial fluid biochemical markers such as α defensin are less sensitive than for lower limb arthroplasty. A structured approach is necessary when assessing patients for prosthetic shoulder joint infection. This includes history, examination, serum inflammatory markers, plain radiology and aspiration and/or biopsy. A classification for the likelihood of prosthetic shoulder infection has been described based on culture, pre-operative and intra-operative findings. Treatment options include antibiotic suppression, debridement with component retention, one-stage revision, two-stage revision and excision arthroplasty. Revision arthroplasty is associated with the best outcomes.

  18. Characterization of microbes in prosthetic joint specimens by culture-independent molecular methods

    DEFF Research Database (Denmark)

    Xu, Yijuan; Rudkjøbing, Vibeke Børsholt; Simonsen, Ole

    Prosthetic joint infection (PJI) is one of the most challenging complications of joint alloplasty. Formation of biofilm is a prominent feature of PJIs and constitutes a challenge to current sampling procedures and culture practices to obtain a reliable diagnosis. The aim of the study was to inves......Prosthetic joint infection (PJI) is one of the most challenging complications of joint alloplasty. Formation of biofilm is a prominent feature of PJIs and constitutes a challenge to current sampling procedures and culture practices to obtain a reliable diagnosis. The aim of the study...... was to investigate the microbial diversity in surgical samples (eg. synovial fluid, periprosthetic tissue, removed prosthesis) from 22 prosthetic patients using a range of culture-independent molecular methods including broad range 16S rRNA gene PCR, cloning, phylogeny, quantitative PCR (qPCR), and fluorescence...

  19. Severe prosthetic joint infection in an immunocompetent male patient due to a therapy refractory Pseudallescheria apiosperma.

    NARCIS (Netherlands)

    Lackner, M.; Man, F.H. de; Eygendaal, D.; Wintermans, R.G.; Kluytmans, J.A.; Klaassen, C.H.; Meis, J.F.G.M.

    2011-01-01

    Prosthetic joint infections (PJI) are rarely due to fungal agents and if so they are mainly caused by Candida strains. This case represents a PJI caused by a multi-drug resistant Pseudallescheria apiosperma, with poor in vivo response to itraconazole and voriconazole. This case differs also by the

  20. Synovial calprotectin: a potential biomarker to exclude a prosthetic joint infection.

    Science.gov (United States)

    Wouthuyzen-Bakker, M; Ploegmakers, J J W; Kampinga, G A; Wagenmakers-Huizenga, L; Jutte, P C; Muller Kobold, A C

    2017-05-01

    Recently, several synovial biomarkers have been introduced into the algorithm for the diagnosis of a prosthetic joint infection (PJI). Alpha defensin is a promising biomarker, with a high sensitivity and specificity, but it is expensive. Calprotectin is a protein that is present in the cytoplasm of neutrophils, is released upon neutrophil activation and exhibits anti-microbial activity. Our aim, in this study, was to determine the diagnostic potential of synovial calprotectin in the diagnosis of a PJI. In this pilot study, we prospectively collected synovial fluid from the hip, knee, shoulder and elbow of 19 patients with a proven PJI and from a control group of 42 patients who underwent revision surgery without a PJI. PJI was diagnosed according to the current diagnostic criteria of the Musculoskeletal Infection Society. Synovial fluid was centrifuged and the supernatant was used to measure the level of calprotectin after applying a lateral flow immunoassay. The median synovial calprotectin level was 991 mg/L (interquartile range (IQR) 154 to 1787) in those with a PJI and 11 mg/L (IQR 3 to 29) in the control group (p infection. With a lateral flow immunoassay, a relatively rapid quantitative diagnosis can be made. The measurement is cheap and is easy to use. Cite this article: Bone Joint J 2017;99-B:660-5. ©2017 The British Editorial Society of Bone & Joint Surgery.

  1. Sonication contribution to identifying prosthetic joint infection with Ralstonia pickettii: a case report and review of the literature.

    Science.gov (United States)

    Birlutiu, Rares Mircea; Roman, Mihai Dan; Cismasiu, Razvan Silviu; Fleaca, Sorin Radu; Popa, Crina Maria; Mihalache, Manuela; Birlutiu, Victoria

    2017-07-19

    In the context of an increase number of primary and revision total hip and total knee arthroplasty performed yearly, an increased risk of complication is expected. Prosthetic joint infection (PJI) remains the most common and feared arthroplasty complication. Ralstonia pickettii is a Gram-negative bacterium, that has also been identified in biofilms. It remains an extremely rare cause of PJI. There is no report of an identification of R. pickettii on an extracted spacer loaded with antibiotic. We present the case of an 83-years-old Caucasian male patient, that underwent a right cemented total hip replacement surgery. The patient is diagnosed with an early PJI with no isolated microorganism. A debridement and change of mobile parts is performed. At the beginning of 2016, the patient in readmitted into the Orthopedic Department for sever, right abdominal and groin pain and elevated serum erythrocyte sedimentation rate and C-reactive protein. A joint aspiration is performed with a negative microbiological examination. A two-stage exchange with long interval management is adopted, and a preformed spacer loaded with gentamicin was implanted. In July 2016, based on the proinflammatory markers evolution, a shift a three-stage exchange strategy is decided. In September 2016, a debridement, and changing of the preformed spacer loaded with gentamicin with another was carried out. Bacteriological examination of the tissues sampled intraoperatively was positive for Pseudomonas aeruginosa. From the sonication fluid, no bacteria were isolated on culture or identified using the bbFISH assay. During the hospitalization period, the patient received i.v. ceftazidime 3x2g/day and p.o. ciprofloxacin 2x750mg/day, antibiotic therapy that was continued after discharge with p.o. ciprofloxacin 2x750mg/day for 6 weeks. In February 2017, a reimplantation of a revision prosthesis is performed. The retrieved spacer is sonicated, and after 4 days of incubation of the sonication fluid, R

  2. A Novel Prosthetic Joint Infection Pathogen, Mycoplasma salivarium, Identified by Metagenomic Shotgun Sequencing.

    Science.gov (United States)

    Thoendel, Matthew; Jeraldo, Patricio; Greenwood-Quaintance, Kerryl E; Chia, Nicholas; Abdel, Matthew P; Steckelberg, James M; Osmon, Douglas R; Patel, Robin

    2017-07-15

    Defining the microbial etiology of culture-negative prosthetic joint infection (PJI) can be challenging. Metagenomic shotgun sequencing is a new tool to identify organisms undetected by conventional methods. We present a case where metagenomics was used to identify Mycoplasma salivarium as a novel PJI pathogen in a patient with hypogammaglobulinemia. © The Author 2017. Published by Oxford University Press for the Infectious Diseases Society of America. All rights reserved. For permissions, e-mail: journals.permissions@oup.com.

  3. Contribution of a multiplex serological test for the preoperative diagnosis of prosthetic joint infection: a prospective study.

    Science.gov (United States)

    de Seynes, Camille; de Barbeyrac, Bertille; Dutronc, Hervé; Ribes, Clément; Crémer, Paul; Dubois, Véronique; Fabre, Thierry; Dupon, Michel; Dauchy, Frédéric-Antoine

    2018-03-22

    Prosthetic joint infection (PJI) is a severe complication of orthopaedic surgery. Preoperative diagnosis, although sometimes difficult, is key to choose the relevant treatment. We conducted a prospective study aimed at evaluating the diagnostic performance of a multiplex serological test for the pre-operative diagnosis of PJI. Blood samples were collected between 1 July 2016 and 31 July 2017 among patients referred for suspected PJI that occurred at least six weeks prior. Infection diagnosis was confirmed using intraoperative bacteriological cultures during prosthetic exchange. Seventy-one patients were included, with a median age of 73 years (interquartile range [IQR]: 66-81) and 40 (56%) were male. Twenty-six patients had aseptic loosening and 45 patients had PJI. Among the latter, median time since the last surgery was 96 weeks (IQR: 20-324). Intraoperative cultures found Staphylococcus spp, Streptococcus spp or both in 39, 5 and 1 patients, respectively. Sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) were 81.8, 95.4, 97.3 and 72.4%, respectively, for all patients and 87.5, 93.5, 94.6 and 85.3%, respectively, for staphylococcal infections. Patients with false negative (FN) results had a significantly lower blood lymphocyte count (p = .045). Multiplex serological test performed well among patients with chronic staphylococcal prosthetic infection. This approach could contribute to PJI diagnosis especially in patients for whom the pre-operative analysis of joint fluid is not informative.

  4. Differential contributions of specimen types, culturing, and 16S rRNA sequencing in diagnosis of prosthetic joint infections

    DEFF Research Database (Denmark)

    Larsen, Lone Heimann; Khalid, Vesal; Xu, Yijuan

    2018-01-01

    to variations in specimen sampling. In this prospective, multidisciplinary study of hip or knee prosthetic failures, we assessed the contributions of different specimen types, extended culture incubations, and 16S rRNA sequencing for diagnosing prosthetic joint infections (PJI). Project specimens included joint...... fluid (JF), bone biopsy specimens (BB), soft-tissue biopsy specimens (STB), and swabs (SW) from the prosthesis, collected in situ, and sonication fluid collected from prosthetic components (PC). Specimens were cultured for 6 (conventional) or 14 days, and 16S rRNA sequencing was performed at study...... completion. Of the 156 patients enrolled, 111 underwent 114 surgical revisions (cases) due to indications of either PJI (n = 43) or AF (n = 71). Conventional tissue biopsy cultures confirmed PJI in 28/43 (65%) cases and refuted AF in 3/71 (4%) cases; one case was not evaluable. Based on these results, minor...

  5. [Tuberculous prosthetic knee joint infection: a case report and literature review].

    Science.gov (United States)

    Lara-Oya, A; Liébana-Martos, M C; Rodríguez-Granger, J; Sampedro-Martínez, A; Aliaga-Martínez, L; Gutierrez-Fernández, J; Navarro-Marí, J M

    2016-08-01

    Prosthetic late infection occurs in the second month after surgery in the context of haematogenous spread from another source. Prosthetic mycobacterial infection is a rare complication whose clinical management is not standardized. Patient of 77 years with no personal history except for diabetes and a prosthetic replacement of right knee with osteoarthritis three years ago. Patient goes to hospital emergency box for 6 months pain in the right knee with mechanical inflammatory signs but no fever associated. After their return within 5 days and clinical worsening is reporting growth of Mycobacterium tuberculosis in knee aspirate and antitubercular treatment is established for 9 months. Nuclear magnetic resonance imaging studies also confirmed the diagnosis of tuberculosis spondylitis in the clinical context of the patients. After surgery, M. tuberculosis was again isolated from intraoperative samples and therefore the patient received another batch of treatment for 9 months. After a year of monitoring, the development was acceptable but few months later, the patient died for cardiovascular causes. In the literature review, 15 publications with a total of 17 clinical cases of prosthetic infection by M. tuberculosis were found from 1980 to 2014. Prosthetic tuberculous arthritis, although it is a rare presentation, it should be noted, especially in patients with predisposing conditions with a history of tuberculosis infection.

  6. Prevention of Infection in Orthopedic Prosthetic Surgery.

    Science.gov (United States)

    Chirca, Ioana; Marculescu, Camelia

    2017-06-01

    Total joint arthroplasty is a generally safe orthopedic procedure; however, infection is a potentially devastating complication. Multiple risk factors have been identified for development of prosthetic joint infections. Identification of patients at risk and preoperative correction of known risk factors, such as smoking, diabetes mellitus, anemia, malnutrition, and decolonization of Staphylococcus carriers, represent well-established actions to decrease the infection risk. Careful operative technique, proper draping and skin preparation, and appropriate selection and dosing of antimicrobials for perioperative prophylaxis are also very important in prevention of infection. Published by Elsevier Inc.

  7. Introduction to the Centers for Disease Control and Prevention and Healthcare Infection Control Practices Advisory Committee Guideline for Prevention of Surgical Site Infection: Prosthetic Joint Arthroplasty Section.

    Science.gov (United States)

    Segreti, John; Parvizi, Javad; Berbari, Elie; Ricks, Philip; Berríos-Torres, Sandra I

    Peri-prosthetic joint infection (PJI) is a severe complication of total joint arthroplasty that appears to be increasing as more of these procedures are performed. Numerous risk factors for incisional (superficial and deep) and organ/space (e.g., PJI) surgical site infections (SSIs) have been identified. A better understanding and reversal of modifiable risk factors may lead to a reduction in the incidence of incisional SSI and PJI. The Centers for Disease Control and Prevention (CDC) and the Healthcare Infection Control Practices Advisory Committee (HICPAC) recently updated the national Guideline for Prevention of Surgical Site Infection. The updated guideline applies evidence-based methodology, presents recommendations for potential strategies to reduce the risk of SSI, and includes an arthroplasty-specific section. This article serves to introduce the guideline development process and to complement the Prosthetic Joint Arthroplasty section with background information on PJI-specific economic burden, epidemiology, pathogenesis and microbiology, and risk factor information.

  8. Conventional and molecular diagnostic strategies for prosthetic joint infections.

    Science.gov (United States)

    Esteban, Jaime; Sorlí, Luisa; Alentorn-Geli, Eduard; Puig, Lluís; Horcajada, Juan P

    2014-01-01

    An accurate diagnosis of prosthetic joint infection (PJI) is the mainstay for an optimized clinical management. This review analyzes different diagnostic strategies of PJI, with special emphasis on molecular diagnostic tools and their current and future applications. Until now, the culture of periprosthetic tissues has been considered the gold standard for the diagnosis of PJI. However, sonication of the implant increases the sensitivity of those cultures and is being increasingly adopted by many centers. Molecular diagnostic methods compared with intraoperative tissue culture, especially if combined with sonication, have a higher sensitivity, a faster turnaround time and are not influenced by previous antimicrobial therapy. However, they still lack a system for detection of antimicrobial susceptibility, which is crucial for an optimized and less toxic therapy of PJI. More studies are needed to assess the clinical value of these methods and their cost-effectiveness.

  9. Is Asymptomatic Bacteriuria a Risk Factor for Prosthetic Joint Infection?

    Science.gov (United States)

    Sousa, Ricardo; Muñoz-Mahamud, Ernesto; Quayle, Jonathan; Dias da Costa, Luis; Casals, Cristina; Scott, Phylip; Leite, Pedro; Vilanova, Paz; Garcia, Sebastian; Ramos, Maria Helena; Dias, Joana; Soriano, Alex; Guyot, Andrea

    2014-01-01

    Background. Infection is a major complication after total joint arthroplasty. The urinary tract is a possible source of surgical site contamination, but the role of asymptomatic bacteriuria (ASB) before elective surgery and the subsequent risk of infection is poorly understood. Methods. Candidates for total hip or total knee arthroplasty were reviewed in a multicenter cohort study. A urine sample was cultured in all patients, and those with ASB were identified. Preoperative antibiotic treatment was decided on an individual basis, and it was not mandatory or randomized. The primary outcome was prosthetic joint infection (PJI) in the first postoperative year. Results. A total of 2497 patients were enrolled. The prevalence of ASB was 12.1% (303 of 2497), 16.3% in women and 5.0% in men (odds ratio, 3.67; 95% confidence interval, 2.65–5.09; P infection rate was significantly higher in the ASB group than in the non-ASB group (4.3% vs 1.4%; odds ratio, 3.23; 95% confidence interval, 1.67–6.27; P = .001). In the ASB group, there was no significant difference in PJI rate between treated (3.9%) and untreated (4.7%) patients. The ASB group had a significantly higher proportion of PJI due to gram-negative microorganisms than the non-ASB group, but these did not correlate to isolates from urine cultures. Conclusions. ASB was an independent risk factor for PJI, particularly that due to gram-negative microorganisms. Preoperative antibiotic treatment did not show any benefit and cannot be recommended. PMID:24723280

  10. Detection and identification of microbes in prosthetic joint infections by culture and molecular methods

    DEFF Research Database (Denmark)

    Xu, Yijuan; Schønheyder, Henrik Carl; Ehrlich, Garth

    , indicating biofilm formation. In conclusion, this study indicated that to improve the microbiological diagnosis of prosthetic joint infections molecular methods may be useful supplements to routine cultures, and the current intraoperative sampling strategy needs to be optimized.......Bacterial biofilms have been observed in many device-related infections including orthopedic implants. This mode of growth makes the infection difficult to treat and constitutes a challenge to current sampling procedures and culture practices to obtain a reliable diagnosis. The aim of the study...... uncovered many more species including known pathogens and species not previously reported in orthopedic infections, and polymicrobial communities were commonly observed. Additionally the molecular findings suggested the bacterial composition and yield varied depending on the position and type of samples...

  11. Increased Mortality After Prosthetic Joint Infection in Primary THA

    DEFF Research Database (Denmark)

    Gundtoft, Per Hviid; Pedersen, Alma Becic; Varnum, Claus

    2017-01-01

    among patients with PJI that are associated with an increased risk of death? Methods: This population-based cohort study was based on the longitudinally maintained Danish Hip Arthroplasty Register on primary THA performed in Denmark from 2005 to 2014. Data from the Danish Hip Arthroplasty Register were......Background: Revision for prosthetic joint infection (PJI) has a major effect on patients’ health but it remains unclear if early PJI after primary THA is associated with a high mortality. Questions/Purposes: (1) Do patients with a revision for PJI within 1 year of primary THA have increased...... mortality compared with patients who do not undergo revision for any reason within 1 year of primary THA? (2) Do patients who undergo a revision for PJI within 1 year of primary THA have an increased mortality risk compared with patients who undergo an aseptic revision? (3) Are there particular bacteria...

  12. Diffuse skin hyperpigmentation associated with chronic minocycline use in a patient with prosthetic joint infection

    Directory of Open Access Journals (Sweden)

    Hadi Berbari

    2017-01-01

    Full Text Available Cutaneous hyperpigmentation is a recognized adverse effect of chronic minocycline use occurring in up to 50% of patients. In this report we present a rare case of extensive skin hyperpigmentation involving both lower extremities in a patient receiving long term minocycline. The patient was receiving minocycline as suppression for chronic prosthetic joint infection. Risk factors associated with minocycline-induced cutaneous pigmentation (MICH will be reviewed.

  13. Daptomycin in the treatment of prosthetic joint infection by Enterococcus faecalis: safety and efficacy of high-dose and prolonged therapy

    OpenAIRE

    José Ramón Yuste; Milena Quesada; Pablo Díaz-Rada; José Luis Del Pozo

    2014-01-01

    Enterococci are implicated in less than 2.3% of prosthetic joint infections. These infections can be difficult to treat and therapeutic failures are not uncommon. In these situations, daptomycin is a safe and effective alternative. We present a clinical case with a successful response to the prolonged use of high-dose daptomycin.

  14. Rapidly-growing mycobacterial infection: a recognized cause of early-onset prosthetic joint infection.

    Science.gov (United States)

    Jitmuang, Anupop; Yuenyongviwat, Varah; Charoencholvanich, Keerati; Chayakulkeeree, Methee

    2017-12-28

    Prosthetic joint infection (PJI) is a major complication of total hip and total knee arthroplasty (THA, TKA). Although mycobacteria are rarely the causative pathogens, it is important to recognize and treat them differently from non-mycobacterial infections. This study aimed to compare the clinical characteristics, associated factors and long-term outcomes of mycobacterial and non-mycobacterial PJI. We conducted a retrospective case-control study of patients aged ≥18 years who were diagnosed with PJI of the hip or knee at Siriraj Hospital from January 2000 to December 2012. Patient characteristics, clinical data, treatments and outcomes were evaluated. A total of 178 patients were included, among whom 162 had non-mycobacterial PJI and 16 had mycobacterial PJI. Rapidly growing mycobacteria (RGM) (11) and M. tuberculosis (MTB) (5) were the causative pathogens of mycobacterial PJI. PJI duration and time until onset were significantly different between mycobacterial and non-mycobacterial PJI. Infection within 90 days of arthroplasty was significantly associated with RGM infection (OR 21.86; 95% CI 4.25-112.30; p infection. RGM were the major pathogens of early onset PJI after THA and TKA. Both a high clinical index of suspicion and mycobacterial cultures are recommended when medically managing PJI with negative cultures or non-response to antibiotics. Removal of infected implants was associated with favorable outcomes.

  15. Daptomycin in the treatment of prosthetic joint infection by Enterococcus faecalis: safety and efficacy of high-dose and prolonged therapy

    Directory of Open Access Journals (Sweden)

    José Ramón Yuste

    2014-10-01

    Full Text Available Enterococci are implicated in less than 2.3% of prosthetic joint infections. These infections can be difficult to treat and therapeutic failures are not uncommon. In these situations, daptomycin is a safe and effective alternative. We present a clinical case with a successful response to the prolonged use of high-dose daptomycin.

  16. The Effect of Preoperative Antimicrobial Prophylaxis on Intraoperative Culture Results in Patients with a Suspected or Confirmed Prosthetic Joint Infection : A Systematic Review

    NARCIS (Netherlands)

    Wouthuyzen-Bakker, Marjan; Benito, Natividad; Soriano, Alex

    Obtaining reliable cultures during revision arthroplasty is important to adequately diagnose and treat a prosthetic joint infection (PJI). The influence of antimicrobial prophylaxis on culture results remains unclear. Since withholding prophylaxis increases the risk for surgical site infections,

  17. Treatment of prosthetic joint infections due to Propionibacterium

    Science.gov (United States)

    Van Hooff, Miranda L; Meis, Jacques F; Vos, Fidel; Goosen, Jon H M

    2016-01-01

    Background and purpose Currently, Propionibacterium is frequently recognized as a causative microorganism of prosthetic joint infection (PJI). We assessed treatment success at 1- and 2-year follow-up after treatment of Propionibacterium-associated PJI of the shoulder, hip, and knee. Furthermore, we attempted to determine whether postoperative treatment with rifampicin is favorable. Patients and methods We conducted a retrospective cohort study in which we included patients with a primary or revision joint arthroplasty of the shoulder, hip, or knee who were diagnosed with a Propionibacterium-associated PJI between November 2008 and February 2013 and who had been followed up for at least 1 year. Results We identified 60 patients with a Propionibacterium-associated PJI with a median duration of 21 (0.1–49) months until the occurrence of treatment failure. 39 patients received rifampicin combination therapy, with a success rate of 93% (95% CI: 83–97) after 1 year and 86% (CI: 71–93) after 2 years. The success rate was similar in patients who were treated with rifampicin and those who were not. Interpretation Propionibacterium-associated PJI treated with surgery in combination with long-term antibiotic administration had a successful outcome at 1- and 2-year follow-up irrespective of whether the patient was treated with rifampicin. Prospective studies are needed to determine whether the use of rifampicin is beneficial in the treatment of Propionibacterium-associated PJI. PMID:26414972

  18. Single-stage revision for fungal peri-prosthetic joint infection: a single-centre experience.

    Science.gov (United States)

    Klatte, T O; Kendoff, D; Kamath, A F; Jonen, V; Rueger, J M; Frommelt, L; Gebauer, M; Gehrke, T

    2014-04-01

    Fungal peri-prosthetic infections of the knee and hip are rare but likely to result in devastating complications. In this study we evaluated the results of their management using a single-stage exchange technique. Between 2001 and 2011, 14 patients (ten hips, four knees) were treated for a peri-prosthetic fungal infection. One patient was excluded because revision surgery was not possible owing to a large acetabular defect. One patient developed a further infection two months post-operatively and was excluded from the analysis. Two patients died of unrelated causes. After a mean of seven years (3 to 11) a total of ten patients were available for follow-up. One patient, undergoing revision replacement of the hip, had a post-operative dislocation. Another patient, undergoing revision replacement of the knee, developed a wound infection and required revision 29 months post-operatively following a peri-prosthetic femoral fracture. The mean Harris hip score increased to 74 points (63 to 84; p prosthetic infection is feasible, with an acceptable rate of a satisfactory outcome.

  19. Molecularly specific detection of bacterial lipoteichoic acid for diagnosis of prosthetic joint infection of the bone.

    Science.gov (United States)

    Pickett, Julie E; Thompson, John M; Sadowska, Agnieszka; Tkaczyk, Christine; Sellman, Bret R; Minola, Andrea; Corti, Davide; Lanzavecchia, Antonio; Miller, Lloyd S; Thorek, Daniel Lj

    2018-01-01

    Discriminating sterile inflammation from infection, especially in cases of aseptic loosening versus an actual prosthetic joint infection, is challenging and has significant treatment implications. Our goal was to evaluate a novel human monoclonal antibody (mAb) probe directed against the Gram-positive bacterial surface molecule lipoteichoic acid (LTA). Specificity and affinity were assessed in vitro. We then radiolabeled the anti-LTA mAb and evaluated its effectiveness as a diagnostic imaging tool for detecting infection via immunoPET imaging in an in vivo mouse model of prosthetic joint infection (PJI). In vitro and ex vivo binding of the anti-LTA mAb to pathogenic bacteria was measured with Octet, ELISA, and flow cytometry. The in vivo PJI mouse model was assessed using traditional imaging modalities, including positron emission tomography (PET) with [ 18 F]FDG and [ 18 F]NaF as well as X-ray computed tomography (CT), before being evaluated with the zirconium-89-labeled antibody specific for LTA ([ 89 Zr]SAC55). The anti-LTA mAb exhibited specific binding in vitro to LTA-expressing bacteria. Results from imaging showed that our model could reliably simulate infection at the surgical site by bioluminescent imaging, conventional PET tracer imaging, and bone morphological changes by CT. One day following injection of both the radiolabeled anti-LTA and isotype control antibodies, the anti-LTA antibody demonstrated significantly greater ( P  infected prosthesis sites over either the same antibody at sterile prosthesis sites or of control non-specific antibody at infected prosthesis sites. Taken together, the radiolabeled anti-LTA mAb, [ 89 Zr]SAC55, may serve as a valuable diagnostic molecular imaging probe to help distinguish between sterile inflammation and infection in the setting of PJI. Future studies are needed to determine whether these findings will translate to human PJI.

  20. Predictors of revision, prosthetic joint infection and mortality following total hip or total knee arthroplasty in patients with rheumatoid arthritis

    DEFF Research Database (Denmark)

    Cordtz, Rene Lindholm; Zobbe, Kristian; Højgaard, Pil

    2018-01-01

    OBJECTIVES: To investigate predictors of 10-year risk of revision and 1-year risk of prosthetic joint infection (PJI) and death following total hip/total knee arthroplasty (THA/TKA) in (1) patients with rheumatoid arthritis (RA) compared with patients with osteoarthritis (OA); and (2) patients...

  1. Excellent AUC for joint fluid cytology in the detection/exclusion of hip and knee prosthetic joint infection.

    Science.gov (United States)

    Gallo, Jiri; Juranova, Jarmila; Svoboda, Michal; Zapletalova, Jana

    2017-09-01

    The aim of this study was to evaluate the characteristics of synovial fluid (SF) white cell count (SWCC) and neutrophil/lymphocyte percentage in the diagnosis of prosthetic joint infection (PJI) for particular threshold values. This was a prospective study of 391 patients in whom SF specimens were collected before total joint replacement revisions. SF was aspirated before joint capsule incision. The PJI diagnosis was based only on non-SF data. Receiver operating characteristic plots were constructed for the SWCC and differential counts of leukocytes in aspirated fluid. Logistic binomic regression was used to distinguish infected and non-infected cases in the combined data. PJI was diagnosed in 78 patients, and aseptic revision in 313 patients. The areas (AUC) under the curve for the SWCC, the neutrophil and lymphocyte percentages were 0.974, 0.962, and 0.951, respectively. The optimal cut-off for PJI was 3,450 cells/μL, 74.6% neutrophils, and 14.6% lymphocytes. Positive likelihood ratios for the SWCC, neutrophil and lymphocyte percentages were 19.0, 10.4, and 9.5, respectively. Negative likelihood ratios for the SWCC, neutrophil and lymphocyte percentages were 0.06, 0.076, and 0.092, respectively. Based on AUC, the present study identified cut-off values for the SWCC and differential leukocyte count for the diagnosis of PJI. The likelihood ratio for positive/negative SWCCs can significantly change the pre-test probability of PJI.

  2. Tubercular prosthetic joint infection: two case reports and literature review.

    Science.gov (United States)

    Veloci, Sara; Mencarini, Jessica; Lagi, Filippo; Beltrami, Giovanni; Campanacci, Domenico Andrea; Bartoloni, Alessandro; Bartalesi, Filippo

    2018-02-01

    Tubercular prosthetic joint infection (TB-PJI) is an uncommon complication. Lack of evidence of systemic tuberculosis and clinical suspicion could bring a delay in the time of the diagnosis. The aims of this study are to underline the importance of awareness and suspicion of mycobacterial infection in the differential diagnosis in PJI and to evaluate the appropriateness of different therapeutic options. Case report and literature review. We report two cases of TB-PJI after total knee arthroplasty in Caucasian patients without prior history of tubercular disease or exposure. In both cases, the diagnosis was obtained years after the onset of symptoms. Despite that, both patients improved during antitubercular treatment (a four-drug regimen consisting of rifampicin, isoniazid, ethambutol, and pyrazinamide for 2 months, followed by rifampicin and isoniazid). Moreover, after an 18-month course of treatment, there was no need for surgical therapy. The result of the literature review allows us to identify 64 cases of TB-PJI. Many differences in both medical and surgical management have been found, among those reviewed cases. Considering our experience and the literature review, we recommend considering a conservative approach (debridement and adequate antituberculous chemotherapy) as a suitable and safe option.

  3. Moxifloxacin plus rifampin as an alternative for levofloxacin plus rifampin in the treatment of a prosthetic joint infection with staphylococcus aureus

    NARCIS (Netherlands)

    Wouthuyzen-Bakker, Marjan; Tornero, Eduard; Morata, Laura; Panday, Prashant V Nannan; Jutte, Paul C; Bori, Guillem; Kampinga, Greetje A; Soriano, Alex

    OBJECTIVES: The combination of a fluorquinolone with rifampin is one of the cornerstones in the treatment of a prosthetic joint infection (PJI) caused by staphylococci. Moxifloxacin is highly active against methicillin susceptible S. aureus (MSSA), and therefore, an attractive agent to use. However,

  4. May one-stage exchange for Candida albicans peri-prosthetic infection be successful?

    Science.gov (United States)

    Jenny, J-Y; Goukodadja, O; Boeri, C; Gaudias, J

    2016-02-01

    Fungal infection of a total joint arthroplasty has a low incidence but is generally considered as more difficult to cure than bacterial infection. As for bacterial infection, two-stage exchange is considered as the gold standard of treatment. We report two cases of one-stage total joint exchange for fungal peri-prosthetic infection with Candida albicans, where the responsible pathogens was only identified on intraoperative samples. This situation can be considered as a one-stage exchange for fungal peri-prosthetic infection without preoperative identification of the responsible organism, which is considered as having a poor prognosis. Both cases were free of infection after two years. One-stage revision has several potential advantages over two-stage revision, including shorter hospital stay and rehabilitation, no interim period with significant functional impairment, shorter antibiotic treatment, better functional outcome and probably lower costs. We suggest that one-stage revision for C. albicans peri-prosthetic infection may be successful even without preoperative fungal identification. Level IV-Historical cases. Copyright © 2015 Elsevier Masson SAS. All rights reserved.

  5. Prosthetic joint infection-a devastating complication of hemiarthroplasty for hip fracture.

    Science.gov (United States)

    Guren, Ellen; Figved, Wender; Frihagen, Frede; Watne, Leiv Otto; Westberg, Marianne

    2017-08-01

    Background and purpose - Hemiarthroplasty is the most common treatment in elderly patients with displaced femoral neck fracture. Prosthetic joint infection (PJI) is a feared complication. The infection rate varies in the literature, and there are limited descriptive data available. We investigated the characteristics and outcome of PJI following hemiarthroplasty over a 15-year period. Patients and methods - Patients with PJI were identified among 519 patients treated with hemiarthroplasty for a femoral neck fracture at Oslo University Hospital between 1998 and 2012. We used prospectively registered data from previous studies, and recorded additional data from the patients' charts when needed. Results - Of the 519 patients, we identified 37 patients (6%) with early PJI. 20 of these 37 patients became free of infection. Soft tissue debridement and retention of implant was performed in 35 patients, 15 of whom became free of infection with an intact arthroplasty. The 1-year mortality rate was 15/37. We found an association between 1-year mortality and treatment failure (p = 0.001). Staphylococcus aureus and polymicrobial infection were the most common microbiological findings, each accounting for 14 of the 37 infections. Enterococcus spp. was found in 9 infections, 8 of which were polymicrobial. There was an association between polymicrobial infection and treatment failure, and between polymicrobial infection and 1-year mortality. Interpretation - PJI following hemiarthroplasty due to femoral neck fracture is a devastating complication in the elderly. We found a high rate of polymicrobial PJIs frequently including Enterococcus spp, which is different from what is common in PJI after elective total hip arthroplasty.

  6. Improved Diagnosis of Prosthetic Joint Infection by Culturing Periprosthetic Tissue Specimens in Blood Culture Bottles

    Directory of Open Access Journals (Sweden)

    Trisha N. Peel

    2016-01-01

    Full Text Available Despite known low sensitivity, culture of periprosthetic tissue specimens on agars and in broths is routine. Culture of periprosthetic tissue samples in blood culture bottles (BCBs is potentially more convenient, but it has been evaluated in a limited way and has not been widely adopted. The aim of this study was to compare the sensitivity and specificity of inoculation of periprosthetic tissue specimens into blood culture bottles with standard agar and thioglycolate broth culture, applying Bayesian latent class modeling (LCM in addition to applying the Infectious Diseases Society of America (IDSA criteria for prosthetic joint infection. This prospective cohort study was conducted over a 9-month period (August 2013 to April 2014 at the Mayo Clinic, Rochester, MN, and included all consecutive patients undergoing revision arthroplasty. Overall, 369 subjects were studied; 117 (32% met IDSA criteria for prosthetic joint infection, and 82% had late chronic infection. Applying LCM, inoculation of tissues into BCBs was associated with a 47% improvement in sensitivity compared to the sensitivity of conventional agar and broth cultures (92.1 versus 62.6%, respectively; this magnitude of change was similar when IDSA criteria were applied (60.7 versus 44.4%, respectively; P = 0.003. The time to microorganism detection was shorter with BCBs than with standard media (P < 0.0001, with aerobic and anaerobic BCBs yielding positive results within a median of 21 and 23 h, respectively. Results of our study demonstrate that the semiautomated method of periprosthetic tissue culture in blood culture bottles is more sensitive than and as specific as agar and thioglycolate broth cultures and yields results faster.

  7. Treatment Challenges of Prosthetic Hip Infection with Associated Iliacus Muscle Abscess: Report of 5 Cases and Literature Review.

    Science.gov (United States)

    Lawrenz, Joshua M; Mesko, Nathan W; Higuera, Carlos A; Molloy, Robert M; Simpfendorfer, Claus; Babic, Maja

    2017-01-01

    Prosthetic joint infection is an unfortunate though well-recognized complication of total joint arthroplasty. An iliacus and/or iliopsoas muscle abscess is a rarely documented presentation of hip prosthetic joint infection. It is thought an unrecognized retroperitoneal nidus of infection can be a source of continual seeding of the prosthetic hip joint, prolonging attempts to eradicate infection despite aggressive debridement and explant attempts. The current study presents five cases demonstrating this clinical scenario, and discusses various treatment challenges. In each case we report the patient's clinical history, pertinent imaging, management and outcome. Diagnosis of the iliacus muscle abscess was made using computed tomography imaging. In brief, the mean number of total drainage procedures (open and percutaneous) per patient was 4.2, and outcomes consisted of one patient with a hip girdlestone, two patients with delayed revisions, and two patients with retained prosthesis. All patients ended with functional pain and on oral antibiotic suppression with an average follow up of 18 months. This article highlights an iliacus muscle abscess as an unrecognized source of infection to a prosthetic hip. It demonstrates resilience to standard treatment protocols for prosthetic hip infection, and is associated with poor patient outcomes. Aggressive surgical debridement appears to remain critical to treatment success, and early retroperitoneal debridement of the abscess should be considered.

  8. Matrix-assisted laser desorption ionization time of flight mass spectrometry and diagnostic testing for prosthetic joint infection in the clinical microbiology laboratory.

    Science.gov (United States)

    Peel, Trisha N; Cole, Nicolynn C; Dylla, Brenda L; Patel, Robin

    2015-03-01

    Identification of pathogen(s) associated with prosthetic joint infection (PJI) is critical for patient management. Historically, many laboratories have not routinely identified organisms such as coagulase-negative staphylococci to the species level. The advent of matrix-assisted laser desorption ionization time of flight mass spectrometry (MALDI-TOF MS) has enhanced clinical laboratory capacity for accurate species-level identification. The aim of this study was to describe the species-level identification of microorganisms isolated from periprosthetic tissue and fluid specimens using MALDI-TOF MS alongside other rapid identification tests in a clinical microbiology laboratory. Results of rapid identification of bacteria isolated from periprosthetic joint fluid and/or tissue specimens were correlated with clinical findings at Mayo Clinic, Rochester, Minnesota, between May 2012 and May 2013. There were 178 PJI and 82 aseptic failure (AF) cases analyzed, yielding 770 organisms (median, 3/subject; range, 1-19/subject). MALDI-TOF MS was employed for the identification of 455 organisms (59%) in 197 subjects (123 PJIs and 74 AFs), with 89% identified to the species level using this technique. Gram-positive bacteria accounted for 68% and 93% of isolates in PJI and AF, respectively. However, the profile of species associated with infection compared to specimen contamination differed. Staphylococcus aureus and Staphylococcus caprae were always associated with infection, Staphylococcus epidermidis and Staphylococcus lugdunensis were equally likely to be a pathogen or a contaminant, whereas the other coagulase-negative staphylococci were more frequently contaminants. Most streptococcal and Corynebacterium isolates were pathogens. The likelihood that an organism was a pathogen or contaminant differed with the prosthetic joint location, particularly in the case of Propionibacterium acnes. MALDI-TOF MS is a valuable tool for the identification of bacteria isolated from patients

  9. Brucella melitensis prosthetic joint infection in a traveller returning to the UK from Thailand: Case report and review of the literature.

    Science.gov (United States)

    Lewis, Joseph M; Folb, Jonathan; Kalra, Sanjay; Squire, S Bertel; Taegtmeyer, Miriam; Beeching, Nick J

    Brucella spp. prosthetic joint infections are infrequently reported in the literature, particularly in returning travellers, and optimal treatment is unknown. We describe a prosthetic joint infection (PJI) caused by Brucella melitensis in a traveller returning to the UK from Thailand, which we believe to be the first detailed report of brucellosis in a traveller returning from this area. The 23 patients with Brucella-related PJI reported in the literature are summarised, together with our case. The diagnosis of Brucella-related PJI is difficult to make; only 30% of blood cultures and 75% of joint aspiration cultures were positive in the reported cases. Culture of intraoperative samples provides the best diagnostic yield. In the absence of radiological evidence of joint loosening, combination antimicrobial therapy alone may be appropriate treatment in the first instance; this was successful in 6/7 [86%] of patients, though small numbers of patients and the likelihood of reporting bias warrant caution in drawing any firm conclusions about optimal treatment. Aerosolisation of synovial fluid during joint aspiration procedures and nosocomial infection has been described. Brucella-related PJI should be considered in the differential of travellers returning from endemic areas with PJI, including Thailand. Personal protective equipment including fit tested filtering face piece-3 (FFP3) mask or equivalent is recommended for personnel carrying out joint aspiration when brucellosis is suspected. Travellers can reduce the risk of brucellosis by avoiding unpasteurised dairy products and animal contact (particularly on farms and abattoirs) in endemic areas and should be counselled regarding these risks as part of their pre-travel assessment. Copyright © 2016 The Author(s). Published by Elsevier Ltd.. All rights reserved.

  10. Prosthetic Hip Loosening Due to Brucellar Infection: Case Report and Literature Review

    Directory of Open Access Journals (Sweden)

    Anis Tebourbi

    2016-12-01

    Full Text Available Context: Brucellosis is actually considered to be the commonest zoonotic infection worldwide; conversely prosthetic infection due to brucella is extremely rare. Although diagnostic is easily achieved, management of such situations is extremely challenging. Aims: To report the case of prosthetic hip loosening due to brucellar infection, discuss management manners and to summarize data about 19 cases reported in the literature. Methods: We report the case of a 73-year-old woman with brucellar prosthetic hip loosening treated with 2-stage exchange of the prosthesis and prolonged double antibiotherapy Results: At two years follow up the patient is pain free with total functional recovery and no clinical and radiographic signs of prosthetic loosening Conclusions: Brucella should be evocated as a cause of total joint arthroplasty infection especially in patients from endemic regions and with occupational exposure. Antibiotic treatment alone can be followed if there are no signs of implant loosening. Tow stage revision should be considered in other cases.

  11. Current antibiotic management of prosthetic joint infections in Italy: the 'Udine strategy'.

    Science.gov (United States)

    Bassetti, Matteo; Cadeo, Barbara; Villa, Giovanni; Sartor, Assunta; Cainero, Vanni; Causero, Araldo

    2014-09-01

    The rate of prosthetic joint infections followed and cured at our institution is constantly increasing, in line with epidemiological data from the recent literature. This is probably related to the greater number of knee and hip prostheses implanted every year. For intermediate and late infections, only the two-stage approach is applied, as this demonstrates the best outcome in our experience. Particular attention is paid to microbiological isolation of the pathogen: multiple samples of tissue are collected during the interventions, and kept in culture for a longer period of time than usual. Sonication of prosthetic devices is used to enhance the sensitivity and specificity of the microbiological cultures. Histological examination influences surgical choices either towards implantation of a new prosthesis or replacement of the spacer. An empirical antibiotic backbone of a glycopeptide/lipopeptide and rifampicin is chosen, due to the leading role of Gram-positive bacteria in this setting and the high incidence of methicillin resistance in our centre (>30%), followed by an antibiotic regimen containing linezolid. If specific risk factors are present, an anti-Gram-negative drug is added to the regimen. Duration of therapy depends upon the approach that is chosen, usually being 6 weeks when the prosthesis is removed. Despite at the moment being limited by its small sample size, data from our experience confirms that our empirical approach may represent a valid choice during the early phase of treatment, by keeping linezolid for a step-down therapy of shorter duration (4 weeks). © The Author 2014. Published by Oxford University Press on behalf of the British Society for Antimicrobial Chemotherapy. All rights reserved. For Permissions, please e-mail: journals.permissions@oup.com.

  12. Periprosthetic hip joint infection with Aspergillus terreus: A clinical case and a review of the literature

    Directory of Open Access Journals (Sweden)

    Rachel Bartash

    2017-12-01

    Full Text Available Fungal periprosthetic joint infections due to Aspergillus species are rare but are associated with significant cost and morbidity. We present a case of Asperigillus terreus prosthetic joint infection of the hip. The patient was successfully treated with a prolonged course of systemic antifungals along with surgical management. Keywords: Fungal prosthetic joint infection, Aspergillus terreus

  13. Corynebacterium minutissimum vascular graft infection: case report and review of 281 cases of prosthetic device-related Corynebacterium infection.

    Science.gov (United States)

    Reece, Rebecca M; Cunha, Cheston B; Rich, Josiah D

    2014-09-01

    Corynebacterium spp. have proven their pathogenic potential in causing infections, particularly in the setting of immunosuppression and prosthetic devices. We conducted a PubMed literature review of all cases of Corynebacterium prosthetic device infections published in the English language through December 2013. The majority of cases involved peritoneal dialysis and central venous catheters, but prosthetic joints and central nervous system shunts/drains were also involved. The management of these cases in terms of retention or removal of the device was not uniform; however, the overall mortality remained the same among both groups. All of these prosthetic device infections pose potential problems in management when the device cannot be removed safely for the patient, especially with the lack of data on the pathogenicity of Corynebacterium species. However with better identification of species and sensitivities, successful treatment is possible even with retention of the device.

  14. A comparison of gallium-67 citrate scintigraphy and indium-111 labelled leukocyte imaging for the diagnosis of prosthetic joint infection. Preliminary results

    International Nuclear Information System (INIS)

    McKillop, J.H.; Cuthbert, G.F.; Gray, H.W.; McKay, Iain; Sturrock, R.D.

    1982-01-01

    Preliminary experience in comparing Gallium-67 imaging in patients with a painful prosthetic joint to the findings on Indium-111 labelled leukocyte imaging is reported. In the small series of patients so far studied, no clear advantage has emerged for either Gallium-67 or Indium-111 leukocyte imaging in terms of sensitivity or specificity for joint prosthesis infection. Should a larger group confirm the preliminary findings, Gallium-67 imaging may be preferable to Indium-111 leukocyte imaging in the patient with the painful joint prosthesis, in view of the greater simplicity of the former technique

  15. Efficacy of Antibiotic Suppressive Therapy in Patients with a Prosthetic Joint Infection.

    Science.gov (United States)

    Wouthuyzen-Bakker, Marjan; Nijman, Jasperina M; Kampinga, Greetje A; van Assen, Sander; Jutte, Paul C

    2017-01-01

    Introduction: For chronic prosthetic joint infections (PJI), complete removal of the infected prosthesis is necessary in order to cure the infection. Unfortunately, a subgroup of patients is not able to undergo a revision surgery due to high surgical risk. Alternatively, these patients can be treated with antibiotic suppressive therapy (AST) to suppress the infection. Aim: To evaluate the efficacy and tolerability of AST. Methods: We retrospectively collected data (period 2009-2015) from patients with a PJI (of hip, knee or shoulder) who were treated with AST at the University Medical Center Groningen, the Netherlands. AST was defined as antibiotic treatment for PJI that was started after the usual 3 months of antibiotic treatment. The time of follow-up was defined from the time point AST was started. Treatment was considered as failed, when the patient still experienced joint pain, when surgical intervention (debridement, removal, arthrodesis or amputation) was needed to control the infection and/or when death occurred due to the infection. Results: We included 21 patients with a median age of 67 years (range 21 - 88) and with a median follow-up of 21 months (range 3 - 81). Coagulase negative staphylococci (CNS) (n=6), S. aureus (n=6) and polymicrobial flora (n=4) were the most frequently found causative pathogens. Most patients with CNS and S. aureus were treated with minocycline (67%) and clindamycin (83%) as AST, respectively. Overall, treatment was successful in 67% of patients. Failure was due to persistent joint pain (n=1), surgical intervention because of an uncontrolled infection (n=3), and death due the infection (n=3). We observed a treatment success of 90% in patients with a 'standard' prosthesis (n=11), compared to only 50% in patients with a tumor-prosthesis (n=10). Also, treatment was successful in 83% of patients with a CNS as causative microorganism for the infection, compared to 50% in patients with a S. aureus . Patients who failed on AST had a

  16. Mycobacterium smegmatis infection of a prosthetic total knee arthroplasty.

    Science.gov (United States)

    Saffo, Zaid; Ognjan, Anthony

    2016-01-01

    The most common organisms causing prosthetic knee joint infections are staphylococci. However, arthroplasty infections with atypical microbial pathogens, such as Mycobacteria can occur. Due to the rarity of mycobacterial prosthetic joint infections, diagnosis, treatment, and management of these atypical infections represent a clinical challenge. A 71-year old female post-operative day 40 after a left total knee arthroplasty was hospitalized secondary to left knee pain and suspected arthroplasty infection. She had failed outpatient oral antimicrobial treatment for superficial stitch abscess; and outpatient IV/Oral antimicrobials for a clinical postoperative septic bursitis. Ultimately, resection arthroplasty with operative tissue acid fast bacterial cultures demonstrated growth of the Mycobacterium smegmatis group. Post-operatively, she completed a combination course of oral doxycycline and levofloxacin and successfully completed a replacement arthroplasty with clinical and microbial resolution of the infection. To our knowledge, literature review demonstrates three case of knee arthroplasty infection caused by the Mycobacterium smegmatis group. Correspondingly, optimal surgical procedures and antimicrobial management including antimicrobial selection, treatment duration are not well defined. Presently, the best treatment options consists of two step surgical management including prosthesis hardware removal followed by extended antimicrobial therapy, followed by consideration for re-implantation arthroplasty. Our case illustrates importance of considering atypical mycobacterial infections in post-operative arthroplasty infections not responding to traditional surgical manipulations and antimicrobials. For an arthroplasty infection involving the atypical Mycobacterium smegmatis group, two step arthroplasty revision, including arthroplasty resection, with a combination of oral doxycycline and levofloxacin can lead to successful infection resolution, allowing for a

  17. Optimal diagnosis, prevention, and management of periprosthetic joint infection

    Directory of Open Access Journals (Sweden)

    Tafer N

    2015-01-01

    Full Text Available Nathalie Tafer,1 Wilson Belaieff,1 Céline Cuérel,1 Matthieu Zingg,1 Pierre Hoffmeyer,1 Ilker Uçkay1,2 1Orthopedic Surgery Department, 2Division of Infectious Diseases, University of Geneva Hospitals and Medical School, Geneva, Switzerland Abstract: The pace of the aging population is steadily rising worldwide with a parallel increase in the demand for joint replacement procedures. With the increasing number of patients undergoing arthroplasty, there is also an increased risk for arthroplasty infection that may lead to severe complications, poorer outcome, and substantial extra costs for health care systems. Current rates of prosthetic joint infection are not dramatically different from the 1960s or 1970s, but some general principles are now better defined, and their management has been studied extensively during the past decades, thus resulting in a change in clinical practice. The purpose of this review is to summarize important principles of prosthetic joint infection to guide the clinician and to contribute to the optimal diagnosis, prevention, and management of periprosthetic joint infections. Keywords: arthroplasty infection, antibiotic therapy, biofilm, surgery, prevention

  18. Mycobacterium avium intracellulare complex causing olecranon bursitis and prosthetic joint infection in an immunocompromised host

    Directory of Open Access Journals (Sweden)

    Eugene M. Tan

    2016-01-01

    Full Text Available Case: A 73-year-old immunocompromised male presented with recurrent left elbow swelling due to Mycobacterium avium intracellulare complex (MAC olecranon bursitis. 3 years after completing MAC treatment, he underwent right total knee arthroplasty (TKA. 1 year later, he developed TKA pain and swelling and was diagnosed with MAC prosthetic joint infection (PJI. He underwent TKA resection, reimplantation, and 12 months of anti-MAC therapy. This patient is the seventh case report of MAC olecranon bursitis and the third case report of MAC PJI. He is the only report of both MAC olecranon bursitis and PJI occurring in the same patient. Informed consent: This patient was informed and agreed to the publication of this material.

  19. Design and Evaluation of a Prosthetic Knee Joint Using the Geared Five-Bar Mechanism.

    Science.gov (United States)

    Sun, Yuanxi; Ge, Wenjie; Zheng, Jia; Dong, Dianbiao

    2015-11-01

    This paper presents the mechanical design, dynamics analysis and ankle trajectory analysis of a prosthetic knee joint using the geared five-bar mechanism. Compared with traditional four-bar or six-bar mechanisms, the geared five-bar mechanism is better at performing diverse movements and is easy to control. This prosthetic knee joint with the geared five-bar mechanism is capable of fine-tuning its relative instantaneous center of rotation and ankle trajectory. The centrode of this prosthetic knee joint, which is mechanically optimized according to the centrode of human knee joint, is better in the bionic performance than that of a prosthetic knee joint using the four-bar mechanism. Additionally, the stability control of this prosthetic knee joint during the swing and stance phase is achieved by a motor. By adjusting the gear ratio of this prosthetic knee joint, the ankle trajectories of both unilateral and bilateral amputees show less deviations from expected than that of the four-bar knee joint.

  20. Diagnosis of prosthetic joint infection with alpha-defensin using a lateral flow device: a multicentre study.

    Science.gov (United States)

    Berger, P; Van Cauter, M; Driesen, R; Neyt, J; Cornu, O; Bellemans, J

    2017-09-01

    The purpose of this current multicentre study is to analyse the presence of alpha-defensin proteins in synovial fluid using the Synovasure lateral flow device and to determine its diagnostic reliability and accuracy compared with the prosthetic joint infection (PJI) criteria produced by the Musculoskeletal Infection Society (MSIS). A cohort of 121 patients comprising 85 total knee arthroplasties and 36 total hip arthroplasties was prospectively evaluated between May 2015 and June 2016 in three different orthopaedic centres. The tests were performed on patients with a chronically painful prosthesis undergoing a joint aspiration in a diagnostic pathway or during revision surgery. Based on the MSIS criteria, 34 patients (28%) would have had a PJI, and 87 patients had no PJI. Testing with the lateral flow device had a sensitivity of 97.1% (95% confidence intervals (CI) 84.5 to 99.9) and a specificity of 96.6% (95% CI 90.3 to 99.2). The positive predictive value was 91.7% (95% CI 77.7% to 98.3), and the negative predictive value was 98.8% (95% CI 93.6 to 99.9). Receiver operator characteristics analysis demonstrated an area under the curve for the Synovasure test of 0.97 (95% CI 0.93 to 1.00). Our findings suggest that the Synovasure test has an excellent diagnostic performance to confirm or reject the diagnosis of a PJI. The results are promising for the care of the painful or problematic knee and hip joint arthroplasty and the test should be considered as part of the diagnostic toolbox for PJIs. Cite this article: Bone Joint J 2017;99-B:1176-82. ©2017 The British Editorial Society of Bone & Joint Surgery.

  1. Sonication technique improves microbiological diagnosis in patients treated with antibiotics before surgery for prosthetic joint infections.

    Science.gov (United States)

    Scorzolini, Laura; Lichtner, Miriam; Iannetta, Marco; Mengoni, Fabio; Russo, Gianluca; Panni, Alfredo Schiavone; Vasso, Michele; Vasto, Michele; Bove, Marco; Villani, Ciro; Mastroianni, Claudio M; Vullo, Vincenzo

    2014-07-01

    Microbiological diagnosis is crucial for the appropriate management of implant-associated orthopedic infections (IAOIs). Sonication of biomaterials for microbiological diagnosis has not yet been introduced in routine clinical practice. Aim of this study was to describe the advantages and feasibility of this procedure in the clinical setting. We prospectively studied 56 consecutive patients undergoing revision because of IAOI and compared the sensitivity of sonication of explanted orthopedic implants with standard cultures. Patients were divided into two groups: those with foreign body infection (FBI, 15 patients) and those with prosthetic joint infection (PJI, 41 patients). Clinical, radiological and microbiological features were recorded. In the PJI group the sensitivity of sonication in detecting bacterial growth was higher than conventional culture (77% vs 34.1% respectively, p0.05). Coagulase-negative Staphylococci accounted for 90% of the bacteria detected by sonication. Moreover, we found that in the PJI group the sensitivity of sonication was not affected by the timing of antibiotic interruption before surgery. Sonication remains an important tool to improve microbiological diagnosis in PJIs, especially in patients who received previous antimicrobial treatment.

  2. Identification of bacteria on the surface of clinically infected and non-infected prosthetic hip joints removed during revision arthroplasties by 16S rRNA gene sequencing and by microbiological culture

    Science.gov (United States)

    Dempsey, Kate E; Riggio, Marcello P; Lennon, Alan; Hannah, Victoria E; Ramage, Gordon; Allan, David; Bagg, Jeremy

    2007-01-01

    It has been postulated that bacteria attached to the surface of prosthetic hip joints can cause localised inflammation, resulting in failure of the replacement joint. However, diagnosis of infection is difficult with traditional microbiological culture methods, and evidence exists that highly fastidious or non-cultivable organisms have a role in implant infections. The purpose of this study was to use culture and culture-independent methods to detect the bacteria present on the surface of prosthetic hip joints removed during revision arthroplasties. Ten consecutive revisions were performed by two surgeons, which were all clinically and radiologically loose. Five of the hip replacement revision surgeries were performed because of clinical infections and five because of aseptic loosening. Preoperative and perioperative specimens were obtained from each patient and subjected to routine microbiological culture. The prostheses removed from each patient were subjected to mild ultrasonication to dislodge adherent bacteria, followed by aerobic and anaerobic microbiological culture. Bacterial DNA was extracted from each sonicate and the 16S rRNA gene was amplified with the universal primer pair 27f/1387r. All 10 specimens were positive for the presence of bacteria by both culture and PCR. PCR products were then cloned, organised into groups by RFLP analysis and one clone from each group was sequenced. Bacteria were identified by comparison of the 16S rRNA gene sequences obtained with those deposited in public access sequence databases. A total of 512 clones were analysed by RFLP analysis, of which 118 were sequenced. Culture methods identified species from the genera Leifsonia (54.3%), Staphylococcus (21.7%), Proteus (8.7%), Brevundimonas (6.5%), Salibacillus (4.3%), Methylobacterium (2.2%) and Zimmermannella (2.2%). Molecular detection methods identified a more diverse microflora. The predominant genus detected was Lysobacter, representing 312 (60.9%) of 512 clones

  3. Design and clinical outcome of a novel 3D-printed prosthetic joint replacement for the human temporomandibular joint.

    Science.gov (United States)

    Ackland, David; Robinson, Dale; Lee, Peter Vee Sin; Dimitroulis, George

    2018-05-11

    Stock prosthetic temporomandibular joint replacements come in limited sizes, and do not always encompass the joint anatomy that presents clinically. The aims of this study were twofold. Firstly, to design a personalized prosthetic total joint replacement for the treatment of a patient's end-stage temporomandibular joint osteoarthritis, to implant the prosthesis into the patient, and assess clinical outcome 12-months post-operatively; and secondly, to evaluate the influence of changes in prosthetic condyle geometry on implant load response during mastication. A 48-year-old female patient with Grade-5 osteoarthritis to the left temporomandibular joint was recruited, and a prosthesis developed to match the native temporomandibular joint anatomy. The prosthesis was 3D printed, sterilized and implanted into the patient, and pain and function measured 12-months post-operatively. The prosthesis load response during a chewing-bite and maximum-force bite was evaluated using a personalized multi-body musculoskeletal model. Simulations were performed after perturbing condyle thickness, neck length and head sphericity. Increases in prosthetic condyle neck length malaligned the mandible and perturbed temporomandibular joint force. Changes in condylar component thickness greatly influenced fixation screw stress response, while a more eccentric condylar head increased prosthetic joint-contact loading. Post-operatively, the prosthetic temporomandibular joint surgery reduced patient pain from 7/10 to 1/10 on a visual analog scale, and increased intercisal opening distance from 22 mm to 38 mm. This study demonstrates effectiveness of a personalized prosthesis that may ultimately be adapted to treat a wide-range of end-stage temporomandibular joint conditions, and highlights sensitivity of prosthesis load response to changes in condylar geometry. Copyright © 2018 Elsevier Ltd. All rights reserved.

  4. Mobility function of a prosthetic knee joint with an automatic stance phase lock.

    Science.gov (United States)

    Andrysek, Jan; Klejman, Susan; Torres-Moreno, Ricardo; Heim, Winfried; Steinnagel, Bryan; Glasford, Shane

    2011-06-01

    There is a need for a prosthetic knee joint design that is technologically and functionally appropriate for use in developing countries. To develop and clinically evaluate a new type of stance phase controlled prosthetic knee joint that provides stance phase stability without inhibiting swing phase flexion. A crossover repeated measures study design comparing the new knee joint to the participant's conventional low- or high-end prosthetic knee joint. The new knee joint was fitted to fourteen individuals aged 15 to 67 years with unilateral lower limb amputations. Walk tests were performed to measure walking speed. Energy expenditure was estimated using the physiological cost index (PCI). Walking speeds with the new knee joint were on average 0.14 m/s faster than conventional low-end knees (p < 0.0001), but 0.07 m/s slower than conventional high-end prosthetic knees (p = 0.008). The PCI was similar across all three knee joint technologies (p = 0.276). Mobility function with the new knee joint, in terms of walking speed, was more closely matched to high-end than low-end prosthetic knee joints. Therefore, given its relatively simple design, the new stance phase control mechanism may offer a functional and cost effective solution for active transfemoral amputees. This paper describes a new type of prosthetic knee joint mechanism that is intended to be cost-effective while providing high-level stance phase function to active individuals with a transfemoral amputation. Initial clinical testing suggests that the new knee joint may have some functional advantages over existing technologies in this category.

  5. Graft-Sparing Strategy for Thoracic Prosthetic Graft Infection.

    Science.gov (United States)

    Uchino, Gaku; Yoshida, Takeshi; Kakii, Bunpachi; Furui, Masato

    2018-04-01

     Thoracic prosthetic graft infection is a rare but serious complication with no standard management. We reported our surgical experience on graft-sparing strategy for thoracic prosthetic graft infection.  This study included patients who underwent graft-sparing surgery for thoracic prosthetic graft infection at Matsubara Tokushukai Hospital in Japan from January 2000 to October 2017.  There were 17 patients included in the analyses, with a mean age at surgery of 71.0 ± 10.5 years; 11 were men. In-hospital mortality was observed in five patients (29.4%).  Graft-sparing surgery for thoracic prosthetic graft infection is an alternative option particularly for early graft infection after hemiarch replacement. Georg Thieme Verlag KG Stuttgart · New York.

  6. Infection imaging with 99mTc-biotin in patients with prosthetic hip replacement

    International Nuclear Information System (INIS)

    Villa, G.; Mariani, G.; Augeri, C.; Pipino, F.; Paganelli, G.; Chinol, M.

    2002-01-01

    Full text: Although the incidence of infection in prosthetic hip joint replacements has decreased from about 10-15 % to about 0.5-2 % over the last 20 years, the total number of infections has actually increased because of the large number of patients undergoing the procedure. The most frequent clinical presentation of this complication is functional impairment and pain, with or without fever and other signs and/or symptoms of infection. The main is differentiating true infection from simple loosening with inflammation of the implanted stem. Scintigraphy with radiolabeled autologous leukocytes (WBC) represents the 'gold standard' nuclear medicine procedure for imaging infection. However, this procedure is time-consuming, expensive, and involves some biological hazard. Preliminary data, obtained during validation of the avidin/111In-biotin approach, have suggested some potential of 111ln-biotin per se to accumulate at sites of infection. In this pilot study we explored the potential of 99mTc-biotin as an infection imaging agent in pts with orthopedic infections. N4-lys-biotin was labeled with 1110 MBq. Sixteen pts bearing a total of 20 prosthetic hip replacements were enrolled in the study (9 women and 7 men, mean age 73.2 yrs). Eight pts had previously undergone removal of their hip prosthesis because of infection, while infection was suspected in the remaining 8 pts. Scintigraphy was recorded 20 min, then 1, 4 and 24 hr after the i.v. injection of 99mTc-biotin. Within 48 hrs of the 99mTc-biotin study, all pts also underwent scintigraphy with 99mTc-HMPAO-WBC. Out of the 20 hips evaluated, 15 turned out to be infected while in the remaining 5 cases pain was only caused by bone-prosthetic loosening and/or conditions other than infection. In 12/15 infected sites scintigraphy was concordantly positive with both procedures, 99mTc-biotin yielding higher target-to-nontarget ratios than 99mTc-HMPAO-WBC in 4 cases and similar values in the other cases. Discordant patterns

  7. [Localized purpura revealing vascular prosthetic graft infection].

    Science.gov (United States)

    Boureau, A S; Lescalie, F; Cassagnau, E; Clairand, R; Connault, J

    2013-07-01

    Prosthetic graft infection after vascular reconstruction is a rare but serious complication. We report a case of infection occurring late after implantation of an iliofemoral prosthetic vascular graft. The Staphylococcus aureus infection was revealed by vascular purpura localized on the right leg 7 years after implantation of a vascular prosthesis. This case illustrates an uncommonly late clinical manifestation presenting as an acute infection 7 years after the primary operation. In this situation, the presentation differs from early infection, which generally occurs within the first four postoperative months. Diagnosis and treatment remain a difficult challenge because prosthetic graft infection is a potentially life-threatening complication. Morbidity and mortality rates are high. Here we detail specific aspects of the clinical and radiological presentation. Copyright © 2013 Elsevier Masson SAS. All rights reserved.

  8. The Effect of Preoperative Antimicrobial Prophylaxis on Intraoperative Culture Results in Patients with a Suspected or Confirmed Prosthetic Joint Infection: a Systematic Review.

    Science.gov (United States)

    Wouthuyzen-Bakker, Marjan; Benito, Natividad; Soriano, Alex

    2017-09-01

    Obtaining reliable cultures during revision arthroplasty is important to adequately diagnose and treat a prosthetic joint infection (PJI). The influence of antimicrobial prophylaxis on culture results remains unclear. Since withholding prophylaxis increases the risk for surgical site infections, clarification on this topic is critical. A systematic review was performed with the following research question: in patients who undergo revision surgery of a prosthetic joint, does preoperative antimicrobial prophylaxis affect the culture yield of intraoperative samples in comparison with nonpreoperative antimicrobial prophylaxis? Seven articles were included in the final analysis. In most studies, standard diagnostic culture techniques were used. In patients with a PJI, pooled analysis showed a culture yield of 88% (145/165) in the prophylaxis group versus 95% (344/362) in the nonprophylaxis group ( P = 0.004). Subanalysis of patients with chronic PJIs showed positive cultures in 88% (78/89) versus 91% (52/57), respectively ( P = 0.59). In patients with a suspected chronic infection, a maximum difference of 4% in culture yield between the prophylaxis and nonprophylaxis groups was observed. With the use of standard culture techniques, antimicrobial prophylaxis seems to affect cultures in a minority of patients. Along with the known risk of surgical site infections due to inadequate timing of antimicrobial prophylaxis, we discourage the postponement of prophylaxis until tissue samples are obtained in revision surgery. Future studies are necessary to conclude whether the small percentage of false-negative cultures after prophylaxis can be further reduced with the use of more-sensitive culture techniques, like sonication. Copyright © 2017 American Society for Microbiology.

  9. Prevention of Periprosthetic Joint Infection

    Directory of Open Access Journals (Sweden)

    Alisina Shahi

    2015-04-01

    Full Text Available Prosthetic joint infection (PJI is a calamitous complication with high morbidity and substantial cost. The reported incidence is low but it is probably underestimated due to the difficulty in diagnosis. PJI has challenged the orthopaedic community for several years and despite all the advances in this field, it is still a real concern with immense impact on patients, and the healthcare system. Eradication of infection can be very difficult. Therefore, prevention remains the ultimate goal. The medical community has executed many practices with the intention to prevent infection and treat it effectively when it encounters. Numerous factors can predispose patients to PJI. Identifying the host risk factors, patients’ health modification, proper wound care, and optimizing operative room environment remain some of the core fundamental steps that can help minimizing the overall incidence of infection. In this review we have summarized the effective prevention strategies along with the recommendations of a recent International Consensus Meeting on Surgical Site and Periprosthetic Joint Infection.

  10. Early Onset Prosthetic Joint Infection and Bacteremia due to Campylobacter fetus Subspecies fetus

    Directory of Open Access Journals (Sweden)

    Igor Dumic

    2017-01-01

    Full Text Available Campylobacter fetus is a zoonotic pathogen that occasionally causes serious, relapsing, invasive disease, especially in immunocompromised hosts. We report a case of relapsing C. fetus diarrheal illness in a 75-year-old woman which resulted in secondary bacteremia and seeding of the left knee prosthetic joint. Patient responded favorably to debridement and retention of prosthesis in addition to six weeks of meropenem followed by chronic oral doxycycline suppressive therapy.

  11. Use of an automated blood culture system (BD BACTEC™) for diagnosis of prosthetic joint infections: easy and fast.

    Science.gov (United States)

    Minassian, Angela M; Newnham, Robert; Kalimeris, Elizabeth; Bejon, Philip; Atkins, Bridget L; Bowler, Ian C J W

    2014-05-04

    For the diagnosis of prosthetic joint infection (PJI) automated BACTEC™ blood culture bottle methods have comparable sensitivity, specificity and a shorter time to positivity than traditional cooked meat enrichment broth methods. We evaluate the culture incubation period required to maximise sensitivity and specificity of microbiological diagnosis, and the ability of BACTEC™ to detect slow growing Propionibacteria spp. Multiple periprosthetic tissue samples taken by a standardised method from 332 patients undergoing prosthetic joint revision arthroplasty were cultured for 14 days, using a BD BACTEC™ instrumented blood culture system, in a prospective study from 1st January to 31st August 2012. The "gold standard" definition for PJI was the presence of at least one histological criterion, the presence of a sinus tract or purulence around the device. Cases where > =2 samples yielded indistinguishable isolates were considered culture-positive. 1000 BACTEC™ bottle cultures which were negative after 14 days incubation were sub-cultured for Propionibacteria spp. 79 patients fulfilled the definition for PJI, and 66 of these were culture-positive. All but 1 of these 66 culture-positive cases of PJI were detected within 3 days of incubation. Only one additional (clinically-insignificant) Propionibacterium spp. was identified on terminal subculture of 1000 bottles. Prolonged microbiological culture for 2 weeks is unnecessary when using BACTEC™ culture methods. The majority of clinically significant organisms grow within 3 days, and Propionibacteria spp. are identified without the need for terminal subculture. These findings should facilitate earlier decisions on final antimicrobial prescribing.

  12. Synovial Fluid α-Defensin as a Biomarker for Peri-Prosthetic Joint Infection: A Systematic Review and Meta-Analysis.

    Science.gov (United States)

    Li, Bin; Chen, Fei; Liu, Yi; Xu, Guokang

    Total joint arthroplasty (TJA) has been one of the most beneficial interventions for treating patients suffering from joint disorders. However, peri-prosthetic joint infection (PJI) is a serious complication that often accompanies TJA and the diagnosis of PJI is remains difficult. Questions remain regarding whether certain biomarkers can be valuable in the diagnosis of PJI. We conducted our systematic review by searching PubMed, Embase, Web of Science, the Cochrane Library, and Science Direct with the key words "periprosthetic joint infection," "synovial fluid," and "α-defensin." Studies that provided sufficient data to construct 2 × 2 contingency tables were chosen based on inclusion and exclusion criteria. The quality of included studies was assessed according to the revised Quality Assessment of Diagnostic Accuracy Studies (QUADAS-2) criteria. The pooled sensitivity, specificity, and diagnostic odds ratio (DOR) were calculated for the included studies. The summary receiver operating characteristic (SROC) curve and the area under the summary receiver operating characteristic (AUSROC) were used to evaluate the overall diagnostic performance. Eight studies were included in this systematic review. Among them four articles were included in meta-analysis. A total of 421 participants were studied in the meta-analysis. The pooled sensitivity, specificity, and DOR were 0.98 (95% confidence interval [CI]: 0.94-1.00), 0.97 (95% CI: 0.95-0.99), and 1095.49 (95% CI: 283.68.58-4230.45), respectively. The AUSROC was 0.9949 (standard error [SE] 0.0095). Synovial fluid α-defensin is a biomarker of high sensitivity and specificity for the diagnosis of PJI.

  13. The diagnostic protocol for evaluation of periprosthetic joint infection

    Directory of Open Access Journals (Sweden)

    Alen Mlekuž

    2015-06-01

    Full Text Available Infection is becoming the most important as well as the most devastating mechanism of prosthetic joint failure. The incidence is increasing due to increased sensitivity of orthopedic surgeons for this diagnosis, better diagnostics, and  because the absolute number of operated patients is increasing and because more often very sick, debilitated, and immunocompromised patients are operated on. The trend shows the incidence to further increase in the years to come. The diagnosis may be very easy in case of high grade processes, but also extremely difficult in low grade infections. Misdiagnosing infection leads to repeat early failures and revisions that are distressing for patients as well as for surgeons. To avoid failures related to misdiagnosed prosthetic joint infections a step-wise algorithm of action is proposed and the diagnostic strength of the steps discussed. The key point is to select the potential candidates to define the possibility of an ongoing infection and then to select the tools to strengthen the suspicion. The further procedures base on the analysis of the pseudo-synovial fluid obtained by aspiration. The diagnostic conclusions form the basis for considered treatment decisions.

  14. Oral Therapy, Microbiological Findings, and Comorbidity Influence the Outcome of Prosthetic Joint Infections Undergoing 2-Stage Exchange.

    Science.gov (United States)

    Ascione, Tiziana; Pagliano, Pasquale; Balato, Giovanni; Mariconda, Massimo; Rotondo, Renato; Esposito, Silvano

    2017-07-01

    The aim of the present study was to investigate potential predictive factors of an unfavorable outcome in patients with prosthetic joint infection (PJI) undergoing 2-stage exchange. Patients with PJI undergoing 2-stage exchange and observed over a 5-year period (2009-2013) were included. Cure was defined by the disappearance of infection after a 96-week follow-up period. Statistical analysis was performed using the Mann-Whitney U test, the Fisher exact test, and the multivariate analysis. One-hundred twenty-two patients with PJI were included (median age, 69 years [range, 36-80 years]; 48% males, 47 hip PJI, and 75 knee PJI). Known comorbidities related to an increased risk of infection were reported in 43 patients (35%). Microbiological definition was obtained in 101 (83%) patients, and Staphylococcus aureus was isolated in 44 (36%) patients. Coagulase-negative staphylococci were isolated in 41 (34%) patients. A favorable outcome was obtained in 102 of 122 patients (84%). After univariate analysis, bacterial growth from operative specimens (P = .007), growth of Gram-positive bacteria (P rate can be reduced with appropriate treatment choices. Copyright © 2017 Elsevier Inc. All rights reserved.

  15. A personalized 3D-printed prosthetic joint replacement for the human temporomandibular joint: From implant design to implantation.

    Science.gov (United States)

    Ackland, David C; Robinson, Dale; Redhead, Michael; Lee, Peter Vee Sin; Moskaljuk, Adrian; Dimitroulis, George

    2017-05-01

    Personalized prosthetic joint replacements have important applications in cases of complex bone and joint conditions where the shape and size of off-the-shelf components may not be adequate. The objective of this study was to design, test and fabricate a personalized 3D-printed prosthesis for a patient requiring total joint replacement surgery of the temporomandibular joint (TMJ). The new 'Melbourne' prosthetic TMJ design featured a condylar component sized specifically to the patient and fixation screw positions that avoid potential intra-operative damage to the mandibular nerve. The Melbourne prosthetic TMJ was developed for a 58-year-old female recipient with end-stage osteoarthritis of the TMJ. The load response of the prosthesis during chewing and a maximum-force bite was quantified using a personalized musculoskeletal model of the patient's masticatory system developed using medical images. The simulations were then repeated after implantation of the Biomet Microfixation prosthetic TMJ, an established stock device. The maximum condylar stresses, screw stress and mandibular stress at the screw-bone interface were lower in the Melbourne prosthetic TMJ (259.6MPa, 312.9MPa and 198.4MPa, respectively) than those in the Biomet Microfixation device (284.0MPa, 416.0MPa and 262.2MPa, respectively) during the maximum-force bite, with similar trends also observed during the chewing bite. After trialing surgical placement and evaluating prosthetic TMJ stability using cadaveric specimens, the prosthesis was fabricated using 3D printing, sterilized, and implanted into the female recipient. Six months post-operatively, the prosthesis recipient had a normal jaw opening distance (40.0 mm), with no complications identified. The new design features and immediate load response of the Melbourne prosthetic TMJ suggests that it may provide improved clinical and biomechanical joint function compared to a commonly used stock device, and reduce risk of intra-operative nerve damage

  16. Prosthetic joint infection, dental treatment and antibiotic prophylaxis

    Directory of Open Access Journals (Sweden)

    Marthinus J. Kotzé

    2009-06-01

    Full Text Available Current international and national prophylactic antibiotic regimens have been analyzed in respect of the prevention of bacteremia after dental and surgical procedures and, therefore, of joint prosthesis infection. This information was used to formulate guidelines for the Department of Maxillofacial and Oral Surgery. Publications since 2003 were used in this research. In addition, recommendations of accredited institutions and associations were examined. These included the guidelines of the American Dental Association in association with the American Academy of Orthopaedic Surgeons (2003, the American Heart Association (2007, the Working Party of the British Society for Antimicrobial Chemotherapy (2006 and the Australian Dental Guidelines (2005. No guidelines published by any institution in South Africa were found. The general rationale for the use of antibiotic prophylaxis for surgical (including dental interventions is that those procedures may result in a bacteremia that may cause infection in joint prostheses. Antibiotics, however, should therefore be administered to susceptible patients, e.g. immunocompromised patients, prior to the development of bacteremia. The guidelines recommended for use in South Africa are based solely on those used outside South Africa. South Africa is regarded as a developing country with its own population and demographic characteristics. Eleven percent of our population is infected with HIV, and a specific guideline for prophylactic antibiotic treatment is, therefore, essential.

  17. Gram-negative prosthetic joint infection: outcome of a debridement, antibiotics and implant retention approach. A large multicentre study.

    Science.gov (United States)

    Rodríguez-Pardo, D; Pigrau, C; Lora-Tamayo, J; Soriano, A; del Toro, M D; Cobo, J; Palomino, J; Euba, G; Riera, M; Sánchez-Somolinos, M; Benito, N; Fernández-Sampedro, M; Sorli, L; Guio, L; Iribarren, J A; Baraia-Etxaburu, J M; Ramos, A; Bahamonde, A; Flores-Sánchez, X; Corona, P S; Ariza, J

    2014-11-01

    We aim to evaluate the epidemiology and outcome of gram-negative prosthetic joint infection (GN-PJI) treated with debridement, antibiotics and implant retention (DAIR), identify factors predictive of failure, and determine the impact of ciprofloxacin use on prognosis. We performed a retrospective, multicentre, observational study of GN-PJI diagnosed from 2003 through to 2010 in 16 Spanish hospitals. We define failure as persistence or reappearance of the inflammatory joint signs during follow-up, leading to unplanned surgery or repeat debridement>30 days from the index surgery related death, or suppressive antimicrobial therapy. Parameters predicting failure were analysed with a Cox regression model. A total of 242 patients (33% men; median age 76 years, interquartile range (IQR) 68-81) with 242 episodes of GN-PJI were studied. The implants included 150 (62%) hip, 85 (35%) knee, five (2%) shoulder and two (1%) elbow prostheses. There were 189 (78%) acute infections. Causative microorganisms were Enterobacteriaceae in 78%, Pseudomonas spp. in 20%, and other gram-negative bacilli in 2%. Overall, 19% of isolates were ciprofloxacin resistant. DAIR was used in 174 (72%) cases, with an overall success rate of 68%, which increased to 79% after a median of 25 months' follow-up in ciprofloxacin-susceptible GN-PJIs treated with ciprofloxacin. Ciprofloxacin treatment exhibited an independent protective effect (adjusted hazard ratio (aHR) 0.23; 95% CI, 0.13-0.40; pInfection © 2014 European Society of Clinical Microbiology and Infectious Diseases.

  18. Salmonella Typhimurium gastroenteritis leading to chronic prosthetic vascular graft infection.

    Science.gov (United States)

    Cullinan, Milo; Clarke, Michael; Dallman, Tim; Peart, Steven; Wilson, Deborah; Weiand, Daniel

    2017-08-01

    Introduction. It is estimated up to 6 % of prosthetic vascular grafts become infected. Staphylococcus aureus is predominant in early infection and coagulase-negative staphylococci are predominant in late infections. Enterobacteriaceae cause 14-40 % of prosthetic vascular graft infections. This is, to our knowledge the first reported case of Salmonella gastroenteritis causing chronic prosthetic vascular graft infection (PVGI). Case presentation. A 57 years old lady presented with signs and symptoms of prosthetic vascular graft infection. Three years earlier, she had undergone a prosthetic axillo-femoral bypass graft for critical limb ischaemia. The infected prosthetic vascular graft was removed and Salmonella Typhimurium was isolated on culture. In the intervening period, Salmonella Typhimurium was isolated from a faecal specimen, collected during an episode of acute gastroenteritis. Whole-genome sequencing (WGS) showed that the respective Salmonella Typhimurium isolates differed by only a single nucleotide polymorphism (SNP). Salmonella Typhimurium was not isolated on culture of a faecal specimen collected five days following cessation of antimicrobial therapy. Six months after removal of the prosthetic graft, the patient remains under follow-up for her peripheral vascular disease, which currently requires no further surgical intervention. Conclusion. This case has clear implications for the management of chronic PVGI. It is vital to collect high-quality surgical specimens for microbiological analysis and empirical choices of antibiotics are unlikely to cover all potential pathogens. It may also be prudent to enquire about a history of acute gastroenteritis when assessing patients presenting with chronic PVGI.

  19. A mechanism to compensate undesired stiffness in joints of prosthetic hands

    NARCIS (Netherlands)

    Smit, G.; Plettenbrug, D.H.; Van der Helm, F.C.T.

    2014-01-01

    Background: Cosmetic gloves that cover a prosthetic hand have a parasitic positive stiffness that counteracts the flexion of a finger joint. Objectives: Reducing the required input torque to move a finger of a prosthetic hand by compensating the parasitic stiffness of the cosmetic glove. Study

  20. 75% success rate after open debridement, exchange of tibial insert, and antibiotics in knee prosthetic joint infections.

    Science.gov (United States)

    Holmberg, Anna; Thórhallsdóttir, Valdís Gudrún; Robertsson, Otto; W-Dahl, Annette; Stefánsdóttir, Anna

    2015-01-01

    Prosthetic joint infection (PJI) is a leading cause of early revision after total knee arthroplasty (TKA). Open debridement with exchange of tibial insert allows treatment of infection with retention of fixed components. We investigated the success rate of this procedure in the treatment of knee PJIs in a nationwide material, and determined whether the results were affected by microbiology, antibiotic treatment, or timing of debridement. 145 primary TKAs revised for the first time, due to infection, with debridement and exchange of the tibial insert were identified in the Swedish Knee Arthroplasty Register (SKAR). Staphylococcus aureus was the most common pathogen (37%) followed by coagulase-negative staphylococci (CNS) (23%). Failure was defined as death before the end of antibiotic treatment, revision of major components due to infection, life-long antibiotic treatment, or chronic infection. The overall healing rate was 75%. The type of infecting pathogen did not statistically significantly affect outcome. Staphylococcal infections treated without a combination of antibiotics including rifampin had a higher failure rate than those treated with rifampin (RR = 4, 95% CI: 2-10). In the 16 cases with more than 3 weeks of symptoms before treatment, the healing rate was 62%, as compared to 77% in the other cases (p = 0.2). The few patients with a revision model of prosthesis at primary operation had a high failure rate (5 of 8). Good results can be achieved by open debridement with exchange of tibial insert. It is important to use an antibiotic combination including rifampin in staphylococcal infections.

  1. Efficacy of a novel PCR- and microarray-based method in diagnosis of a prosthetic joint infection

    Science.gov (United States)

    2014-01-01

    Background and purpose Polymerase chain reaction (PCR) methods enable detection and species identification of many pathogens. We assessed the efficacy of a new PCR and microarray-based platform for detection of bacteria in prosthetic joint infections (PJIs). Methods This prospective study involved 61 suspected PJIs in hip and knee prostheses and 20 negative controls. 142 samples were analyzed by Prove-it Bone and Joint assay. The laboratory staff conducting the Prove-it analysis were not aware of the results of microbiological culture and clinical findings. The results of the analysis were compared with diagnosis of PJIs defined according to the Musculoskeletal Infection Society (MSIS) criteria and with the results of microbiological culture. Results 38 of 61 suspected PJIs met the definition of PJI according to the MSIS criteria. Of the 38 patients, the PCR detected bacteria in 31 whereas bacterial culture was positive in 28 patients. 15 of the PJI patients were undergoing antimicrobial treatment as the samples for analysis were obtained. When antimicrobial treatment had lasted 4 days or more, PCR detected bacteria in 6 of the 9 patients, but positive cultures were noted in only 2 of the 9 patients. All PCR results for the controls were negative. Of the 61 suspected PJIs, there were false-positive PCR results in 6 cases. Interpretation The Prove-it assay was helpful in PJI diagnostics during ongoing antimicrobial treatment. Without preceding treatment with antimicrobials, PCR and microarray-based assay did not appear to give any additional information over culture. PMID:24564748

  2. [124I]FIAU: Human dosimetry and infection imaging in patients with suspected prosthetic joint infection

    International Nuclear Information System (INIS)

    Zhang, Xiaoyan M.; Zhang, Halle H.; McLeroth, Patrick; Berkowitz, Richard D.; Mont, Michael A.; Stabin, Michael G.; Siegel, Barry A.; Alavi, Abass; Barnett, T. Marc; Gelb, Jeffrey; Petit, Chantal; Spaltro, John; Cho, Steve Y.; Pomper, Martin G.; Conklin, James J.; Bettegowda, Chetan; Saha, Saurabh

    2016-01-01

    Introduction: Fialuridine (FIAU) is a nucleoside analog that is a substrate for bacterial thymidine kinase (TK). Once phosphorylated by TK, [ 124 I]FIAU becomes trapped within bacteria and can be detected with positron emission tomography/computed tomography (PET/CT). [ 124 I]FIAU PET/CT has been shown to detect bacteria in patients with musculoskeletal bacterial infections. Accurate diagnosis of prosthetic joint infections (PJIs) has proven challenging because of the lack of a well-validated reference. In the current study, we assessed biodistribution and dosimetry of [ 124 I]FIAU, and investigated whether [ 124 I]FIAU PET/CT can diagnose PJIs with acceptable accuracy. Methods: To assess biodistribution and dosimetry, six subjects with suspected hip or knee PJI and six healthy subjects underwent serial PET/CT after being dosed with 74 MBq (2 mCi) [ 124 I]FIAU intravenously (IV). Estimated radiation doses were calculated with the OLINDA/EXM software. To determine accuracy of [ 124 I]FIAU, 22 subjects with suspected hip or knee PJI were scanned at 2–6 and 24–30 h post IV injection of 185 MBq (5 mCi) [ 124 I]FIAU. Images were interpreted by a single reader blinded to clinical information. Representative cases were reviewed by 3 additional readers. The utility of [ 124 I]FIAU to detect PJIs was assessed based on the correlation of the patient's infection status with imaging results as determined by an independent adjudication board (IAB). Results: The kidney, liver, spleen, and urinary bladder received the highest radiation doses of [ 124 I]FIAU. The effective dose was 0.16 to 0.20 mSv/MBq and doses to most organs ranged from 0.11 to 0.76 mGy/MBq. PET image quality obtained from PJI patients was confounded by metal artifacts from the prostheses and pronounced FIAU uptake in muscle. Consequently, a correlation with infection status and imaging results could not be established. Conclusions: [ 124 I]FIAU was well-tolerated in healthy volunteers and subjects with

  3. [(124)I]FIAU: Human dosimetry and infection imaging in patients with suspected prosthetic joint infection.

    Science.gov (United States)

    Zhang, Xiaoyan M; Zhang, Halle H; McLeroth, Patrick; Berkowitz, Richard D; Mont, Michael A; Stabin, Michael G; Siegel, Barry A; Alavi, Abass; Barnett, T Marc; Gelb, Jeffrey; Petit, Chantal; Spaltro, John; Cho, Steve Y; Pomper, Martin G; Conklin, James J; Bettegowda, Chetan; Saha, Saurabh

    2016-05-01

    Fialuridine (FIAU) is a nucleoside analog that is a substrate for bacterial thymidine kinase (TK). Once phosphorylated by TK, [(124)I]FIAU becomes trapped within bacteria and can be detected with positron emission tomography/computed tomography (PET/CT). [(124)I]FIAU PET/CT has been shown to detect bacteria in patients with musculoskeletal bacterial infections. Accurate diagnosis of prosthetic joint infections (PJIs) has proven challenging because of the lack of a well-validated reference. In the current study, we assessed biodistribution and dosimetry of [(124)I]FIAU, and investigated whether [(124)I]FIAU PET/CT can diagnose PJIs with acceptable accuracy. To assess biodistribution and dosimetry, six subjects with suspected hip or knee PJI and six healthy subjects underwent serial PET/CT after being dosed with 74MBq (2mCi) [(124)I]FIAU intravenously (IV). Estimated radiation doses were calculated with the OLINDA/EXM software. To determine accuracy of [(124)I]FIAU, 22 subjects with suspected hip or knee PJI were scanned at 2-6 and 24-30h post IV injection of 185MBq (5mCi) [(124)I]FIAU. Images were interpreted by a single reader blinded to clinical information. Representative cases were reviewed by 3 additional readers. The utility of [(124)I]FIAU to detect PJIs was assessed based on the correlation of the patient's infection status with imaging results as determined by an independent adjudication board (IAB). The kidney, liver, spleen, and urinary bladder received the highest radiation doses of [(124)I]FIAU. The effective dose was 0.16 to 0.20mSv/MBq and doses to most organs ranged from 0.11 to 0.76mGy/MBq. PET image quality obtained from PJI patients was confounded by metal artifacts from the prostheses and pronounced FIAU uptake in muscle. Consequently, a correlation with infection status and imaging results could not be established. [(124)I]FIAU was well-tolerated in healthy volunteers and subjects with suspected PJI, and had acceptable dosimetry. However, the

  4. Implementation of an Algorithm for Prosthetic Joint Infection: Deviations and Problems.

    Science.gov (United States)

    Mühlhofer, Heinrich M L; Kanz, Karl-Georg; Pohlig, Florian; Lenze, Ulrich; Lenze, Florian; Toepfer, Andreas; von Eisenhart-Rothe, Ruediger; Schauwecker, Johannes

    The outcome of revision surgery in arthroplasty is based on a precise diagnosis. In addition, the treatment varies based on whether the prosthetic failure is caused by aseptic or septic loosening. Algorithms can help to identify periprosthetic joint infections (PJI) and standardize diagnostic steps, however, algorithms tend to oversimplify the treatment of complex cases. We conducted a process analysis during the implementation of a PJI algorithm to determine problems and deviations associated with the implementation of this algorithm. Fifty patients who were treated after implementing a standardized algorithm were monitored retrospectively. Their treatment plans and diagnostic cascades were analyzed for deviations from the implemented algorithm. Each diagnostic procedure was recorded, compared with the algorithm, and evaluated statistically. We detected 52 deviations while treating 50 patients. In 25 cases, no discrepancy was observed. Synovial fluid aspiration was not performed in 31.8% of patients (95% confidence interval [CI], 18.1%-45.6%), while white blood cell counts (WBCs) and neutrophil differentiation were assessed in 54.5% of patients (95% CI, 39.8%-69.3%). We also observed that the prolonged incubation of cultures was not requested in 13.6% of patients (95% CI, 3.5%-23.8%). In seven of 13 cases (63.6%; 95% CI, 35.2%-92.1%), arthroscopic biopsy was performed; 6 arthroscopies were performed in discordance with the algorithm (12%; 95% CI, 3%-21%). Self-critical analysis of diagnostic processes and monitoring of deviations using algorithms are important and could increase the quality of treatment by revealing recurring faults.

  5. Increased Mortality After Prosthetic Joint Infection in Primary THA.

    Science.gov (United States)

    Gundtoft, Per Hviid; Pedersen, Alma Becic; Varnum, Claus; Overgaard, Søren

    2017-11-01

    Revision for prosthetic joint infection (PJI) has a major effect on patients' health but it remains unclear if early PJI after primary THA is associated with a high mortality. (1) Do patients with a revision for PJI within 1 year of primary THA have increased mortality compared with patients who do not undergo revision for any reason within 1 year of primary THA? (2) Do patients who undergo a revision for PJI within 1 year of primary THA have an increased mortality risk compared with patients who undergo an aseptic revision? (3) Are there particular bacteria among patients with PJI that are associated with an increased risk of death? This population-based cohort study was based on the longitudinally maintained Danish Hip Arthroplasty Register on primary THA performed in Denmark from 2005 to 2014. Data from the Danish Hip Arthroplasty Register were linked to microbiology databases, the National Register of Patients, and the Civil Registration System to obtain data on microbiology, comorbidity, and vital status on all patients. Because reporting to the register is compulsory for all public and private hospitals in Denmark, the completeness of registration is 98% for primary THA and 92% for revisions (2016 annual report). The mortality risk for the patients who underwent revision for PJI within 1 year from implantation of primary THA was compared with (1) the mortality risk for patients who did not undergo revision for any reason within 1 year of primary THA; and (2) the mortality risk for patients who underwent an aseptic revision. A total of 68,504 primary THAs in 59,954 patients were identified, of those 445 primary THAs underwent revision for PJI, 1350 primary THAs underwent revision for other causes and the remaining 66,709 primary THAs did not undergo revision. Patients were followed from implantation of primary THA until death or 1 year of followup, or, in case of a revision, 1 year from the date of revision. Within 1 year of primary THA, 8% (95% CI, 6%-11%) of

  6. Preoperative Anemia Is Associated With Failure of Open Debridement Polyethylene Exchange in Acute and Acute Hematogenous Prosthetic Joint Infection.

    Science.gov (United States)

    Swenson, Richard D; Butterfield, James A; Irwin, Timothy J; Zurlo, John J; Davis, Charles M

    2018-06-01

    Acute and acute hematogenous prosthetic joint infections (PJIs) are often treated with open debridement and polyethylene exchange (ODPE) in an effort to save the prosthesis, decrease morbidity, and reduce costs. However, failure of ODPE may compromise a subsequent 2-stage treatment. The purpose of this study is to identify patient factors that impact the success of ODPE for acute and acute hematogenous PJIs. A retrospective review examined comorbidities, preoperative laboratory values, and patient history for patients with successful and failed ODPE treatment for acute perioperative or acute hematogenous periprosthetic hip or knee joint infections. Successful treatment was defined as retaining a well-fixed implant without the need for additional surgery for a minimum of 6-month follow-up with or without lifelong oral maintenance antibiotics. Fifty-three of 72 patients (73.6%) underwent successful ODPE. Of the 19 failures, 14 completed 2-stage revision with one subsequent known failure for recurrent infection. Patients with a Staphylococcus aureus infection were more likely to fail ODPE (48.3% vs 11.6%, P = .0012, odds ratio 7.1, 95% confidence interval 2.3-25.3). Patients with a preoperative hematocrit ≤32.1 were also more likely to fail ODPE (55% vs 16%, P = .0013, odds ratio 6.7, 95% confidence interval 2.2-22.4). When neither risk factor was present, 97.1% of PJIs were successfully treated with ODPE. S aureus infection and preoperative hematocrit ≤32.1 are independent risk factors for ODPE failure. ODPE is a safe alternative to 2-stage revision in patients without preoperative anemia and without S aureus infection. Two-thirds of patients with a failed ODPE were successfully treated with a 2-stage reimplantation. Copyright © 2018 Elsevier Inc. All rights reserved.

  7. Immediate effects of a new microprocessor-controlled prosthetic knee joint: a comparative biomechanical evaluation.

    Science.gov (United States)

    Bellmann, Malte; Schmalz, Thomas; Ludwigs, Eva; Blumentritt, Siegmar

    2012-03-01

    To investigate the immediate biomechanical effects after transition to a new microprocessor-controlled prosthetic knee joint. Intervention cross-over study with repeated measures. Only prosthetic knee joints were changed. Motion analysis laboratory. Men (N=11; mean age ± SD, 36.7±10.2y; Medicare functional classification level, 3-4) with unilateral transfemoral amputation. Two microprocessor-controlled prosthetic knee joints: C-Leg and a new prosthetic knee joint, Genium. Static prosthetic alignment, time-distance parameters, kinematic and kinetic parameters, and center of pressure. After a half-day training and an additional half-day accommodation, improved biomechanical outcomes were demonstrated by the Genium: lower ground reaction forces at weight acceptance during level walking at various velocities, increased swing phase flexion angles during walking on a ramp, and level walking with small steps. Maximum knee flexion angle during swing phase at various velocities was nearly equal for Genium. Step-over-step stair ascent with the Genium knee was more physiologic as demonstrated by a more equal load distribution between the prosthetic and contralateral sides and a more natural gait pattern. When descending stairs and ramps, knee flexion moments with the Genium tended to increase. During quiet stance on a decline, subjects using Genium accepted higher loading of the prosthetic side knee joint, thus reducing same side hip joint loading as well as postural sway. In comparision to the C-Leg, the Genium demonstrated immediate biomechanical advantages during various daily ambulatory activities, which may lead to an increase in range and diversity of activity of people with above-knee amputations. Results showed that use of the Genium facilitated more natural gait biomechanics and load distribution throughout the affected and sound musculoskeletal structure. This was observed during quiet stance on a decline, walking on level ground, and walking up and down ramps and

  8. Success rates for initial eradication of peri-prosthetic knee infection treated with a two-stage procedure.

    Science.gov (United States)

    Kaminski, Andrzej; Citak, Mustafa; Schildhauer, Thomas Armin; Fehmer, Tobias

    2014-01-01

    In Germany, rates of primary total knee arthroplasty procedures and exchange arthroplasty procedures continue to rise. Late-onset peri-prosthetic infection constitutes a serious complication whose management may be dependent upon the spectrum of micro-organisms involved. The aim of this study was to provide a retrospective analysis of the effectiveness of initial eradication measures performed as part of a two-stage procedure. Between 2002 and 2008, a total of 328 patients who had received a first-time diagnosis of chronic peri-prosthetic knee infection following total knee arthroplasty (TKA) subsequently underwent surgery at our clinic. The surgical approach consisted of a two-stage procedure, with the initial procedure consisting of the removal of the prosthesis and radical debridement, followed by insertion of an antibiotic-loaded static spacer. The effectiveness of the procedure was assessed after six weeks, with each patient undergoing a number of clinical and laboratory-based tests, including knee joint aspiration. Staphylococcus aureus strains were responsible for 68% (n=223) of the total number of cases of peri-prosthetic knee infection. 19% of cases (n=62) showed evidence of gram-negative bacteria, while MRSA accounted for 15% (n=49) of cases. Six weeks after completion of the above-named treatment regimen, eradication of infection was considered successful in 289 patients (88.1%). Eradication was unsuccessful in 22% of MRSA infections (n=11) and 7% of MSSA infections (n=23). The treatment regimen outlined in this report is capable of achieving satisfactory results in the management of late-onset peri-prosthetic knee infection, with one exception: patients with infections caused by MRSA showed high failure rates.

  9. 99Tcm-MDP imaging for the diagnosis of joint infection after total hip arthroplasty

    International Nuclear Information System (INIS)

    Li Yuan; Wang Qian; Yue Minggang

    2013-01-01

    Objective: To investigate the value of 99 Tc m -MDP imaging for the differential diagnosis between infection and aseptic loosening after total hip arthroplasty. Methods: During February 2008 to August 2011, 74 patients (32 males, 42 females, average age (64.3±11.2) years) with hip pain after arthroplasty underwent 3-phase (blood flow, blood pool and bone phases) 99 Tc m -MDP imaging. All patients had measurements of serum C reactive protein (CRP) and erythrocyte sedimentation rate (ESR). Joint infection was defined as either increased peri-prosthetic soft tissue activity during perfusion and blood pool phases or increased peri-prosthetic bone activity during uptake phase, or positive in all 3 phases. Aseptic loosening was defined as having negative 99 Tc m -MDP in all 3 phases. Clinical diagnosis was chosen as the gold standard. The blood flow-pool imaging was compared with the serum examinations. χ 2 test was used for statistical analysis. Results: There were 74 symptomatic joints in 74 patients, including 24 joint infections and 50 aseptic loosening. For the detection of peri-prosthetic infection, combined perfusion-blood-pool phase was more accurate than bone uptake phase (90.5% (67/74) vs 55.4% (41/74); χ 2 =23.159, P<0.001), with the sensitivity of 91.7% (22/24) vs 70.8% (17/24) and specificity of 90.0% (45/50) vs 48.0% (24/50), respectively. The blood flow-pool imaging was also more accurate than CRP (73.0% (54/74); χ 2 =7.656, P<0.05) and ESR (71.6% (53/74); χ 2 =8.633, P<0.05), respectively. Conclusion: 99 Tc m -MDP perfusion/blood flow-pool imaging is an accurate modality for differentiating peri-prosthetic infection from aseptic loosening in patients with hip pain after arthroplasty. (authors)

  10. Long-term outcome of acute prosthetic joint infections due to gram-negative bacilli treated with retention of prosthesis.

    Science.gov (United States)

    Jaén, N; Martínez-Pastor, J C; Muñoz-Mahamud, E; García-Ramiro, S; Bosch, J; Mensa, J; Soriano, A

    2012-09-01

    To update the clinical information of the 47 patients with a prosthetic joint infection due to Gram-negative bacilli included in a previous study and to reassess the predictors of failure after a longer follow-up. Using the electronic files of our hospital, all the information regarding readmissions to the hospital, new surgical procedures and the reason for the new surgery (infection, aseptic loosening), and the last visit in the hospital were registered. The medical chart of the 35 patients that were considered in remission in the previous publication was reviewed. In 30 patients no clinical evidence of failure was detected and no additional surgery on the previously infected prosthesis was necessary and they were considered in long-term remission. In 5 cases a late complication was identified. One case had a reinfection due to coagulase-negative staphylococci after 22 months from the open debridement and required a 2-stage revision surgery. The other 4 cases developed an aseptic loosening and it was necessary to perform a 1-stage exchange. Receiving a fluoroquinolone when all the Gram-negatives involved in the infection were susceptible to fluoroquinolones was the only factor associated with remission in the univariate analysis (p=0.002). After a long-term follow-up, our results support the importance of using fluoroquinolones in acute PJI due to Gram-negative bacilli.

  11. Efficacy of indefinite chronic oral antimicrobial suppression for prosthetic joint infection in the elderly: a comparative study.

    Science.gov (United States)

    Prendki, V; Sergent, P; Barrelet, A; Oziol, E; Beretti, E; Berlioz-Thibal, M; Bouchand, F; Dauchy, F A; Forestier, E; Gavazzi, G; Ronde-Oustau, C; Stirnemann, J; Dinh, A

    2017-07-01

    During prosthetic joint infection (PJI), surgical management is sometimes impossible and indefinite chronic oral antimicrobial suppression (ICOAS) may be the only option. The outcomes of elderly patients who benefited from ICOAS with strictly palliative intent were evaluated. A national retrospective cohort study was performed in France, involving patients aged >75 years with a PJI who were managed with planned life-long ICOAS from 2009 to 2014. Patients who experienced an event were compared to those who did not. An event was defined as a composite outcome in patients undergoing ICOAS, including local or systemic progression of the infection, death, or discontinuation of antimicrobial therapy because of an adverse drug reaction. Twenty-one patients were included, with a median age of 85 years (interquartile range 81-88 years). Eight of the 21 patients experienced an event: one had an adverse drug reaction, three had systemic progression of sepsis, and two had local progression. Two of the 21 patients died. No death was related to ICOAS or infection. There was no significant difference between the population with an event and the population free of an event with regard to demographic, clinical, and microbiological characteristics (p>0.05). ICOAS appeared to be an effective and safe option in this cohort. Copyright © 2017 The Author(s). Published by Elsevier Ltd.. All rights reserved.

  12. The relevance of aortic endograft prosthetic infection

    NARCIS (Netherlands)

    Cernohorsky, Paul; Reijnen, Michel M. P. J.; Tielliu, Ignace F. J.; van Sterkenburg, Steven M. M.; van den Dungen, Jan J. A. M.; Zeebregts, Clark J.

    Background: Vascular prosthetic graft infection is a severe complication after open aortic aneurysm repair. Reports of infected endografts are scarce. General treatment consensus with infected graft material is that it should be removed completely. The objective of this study was to describe the

  13. Psoas abscess masquerading as a prosthetic hip infection: A case report.

    Science.gov (United States)

    Atif, Muhammad; Malik, Azeem Tariq; Noordin, Shahryar

    2018-01-01

    Psoas abscess is an unusual condition and is defined as a collection of pus in the iliopsoas compartment. Due to the unique anatomy of psoas muscle it forms a conduit for spread of infection from upper part of body to hip joint in neglected cases. A 67year old lady presented with left groin pain for three weeks. She underwent an uncemented unipolar hemiarthoplasty eight years back. Currently, she developed fever and was unable to do any active left hip range of motion. Passive motion of the left hip was restricted to 30° flexion, no internal rotation, 5° external rotation, and 10° abduction. Lab workup showed raised serum infective markers and radiographs of pelvis were normal with no evidence of any radiolucency. Ultrasound guided aspiration of left hip joint showed E coli. Arthrotomy revealed clear fluid in hip joint but pus was drained at psoas insertion. Later on, culture reported presence of E. coli and biopsy confirmed psoas abscess. Postoperatively CT scan abdomen showed pyelonephritis. Antibiotics were given for three months. Twenty months later, she remains asymptomatic without evidence of infection with normal gait. Psoas abscess is a rare clinical entity that may mimic symptoms of a primary prosthetic hip infection. Treatment outcomes are directly related to early detection with adequate dissection of the psoas muscle up to sites of attachment and complete eradication of infection. This case highlights importance of thorough initial clinical examination, lab workup and radiological assessment to rule out rare causes of hip joint pain. Copyright © 2017. Published by Elsevier Ltd.

  14. Implant salvage in breast reconstruction with severe peri-prosthetic infection.

    Science.gov (United States)

    Meybodi, Farid; Sedaghat, Negin; French, James; Keighley, Caitlin; Mitchell, David; Elder, Elisabeth

    2017-12-01

    Although treatment of mild peri-prosthetic infection in implant-based breast reconstruction results in high rates of resolution, successful management of severe peri-prosthetic infection remains a significant challenge. In this case series, a protocol utilizing a novel dressing - negative pressure wound therapy with instillation (NPWTi) - for the management of severe peri-prosthetic infection in breast reconstruction patients is described. This is an operative technique involving: (i) explantation of the breast prosthesis and application of the NPWTi dressing to the implant pocket; (ii) change of the NPWTi dressing; (iii) intraoperative fluid/tissue cultures; and (iv) reimplantation of the breast prosthesis when cultures yield no growth. This protocol was utilized in six cases of severe peri-prosthetic infection in five patients with immediate breast reconstruction for breast cancer or risk-reducing surgery. Cultures of fluid/tissue grew typical and/or unusual organisms. Only one case did not yield an organism. The hospital length of stay upon completion of the protocol ranged from 7-16 days (mean, 12 days). Successful implant salvage was achieved in five of six cases. The protocol was aborted in one case to allow for completion of adjuvant chemotherapy. Early findings from this case series suggest that in cases of severe peri-prosthetic infection this novel operative protocol may result in successful implant salvage for breast reconstruction patients. Further studies are needed to more fully elaborate the role of NPWTi to achieve implant salvage in challenging cases of peri-prosthetic infection. © 2015 Royal Australasian College of Surgeons.

  15. Most common surgical mistakes with treatment of prosthetic joint infections

    Directory of Open Access Journals (Sweden)

    Boštjan Kocjančič

    2014-08-01

    Full Text Available The treatment of infections of orthopedic implants is often difficult and complex, although the chances of successful treatment with properly selected diagnostics, surgical and antibiotic treatment protocol have recently increased significantly. Surgical treatment is a key stone factor in the treatment of infections of orthopedic implants and any errors in it often lead to worse clinical outcomes. The most important and frequent surgical errors include: conservative treatment of periprothetic infections with antibiotics only, to-late surgical revision, insufficient debridement during surgical revision, inadequate intraoperative samples for bacteriological and histological analysis. It is important to have and to follow proper treatment algorithm for periprosthetic joint infection. In this work we present the listed surgical and most illustrative key errors.

  16. Managing uncertainty - a qualitative study of surgeons' decision-making for one-stage and two-stage revision surgery for prosthetic hip joint infection.

    Science.gov (United States)

    Moore, Andrew J; Blom, Ashley W; Whitehouse, Michael R; Gooberman-Hill, Rachael

    2017-04-12

    Approximately 88,000 primary hip replacements are performed in England and Wales each year. Around 1% go on to develop deep prosthetic joint infection. Between one-stage and two-stage revision arthroplasty best treatment options remain unclear. Our aims were to characterise consultant orthopaedic surgeons' decisions about performing either one-stage or two-stage revision surgery for patients with deep prosthetic infection (PJI) after hip arthroplasty, and to identify whether a randomised trial comparing one-stage with two-stage revision would be feasible. Semi-structured interviews were conducted with 12 consultant surgeons who perform revision surgery for PJI after hip arthroplasty at 5 high-volume National Health Service (NHS) orthopaedic departments in England and Wales. Surgeons were interviewed before the development of a multicentre randomised controlled trial. Data were analysed using a thematic approach. There is no single standardised surgical intervention for the treatment of PJI. Surgeons balance multiple factors when choosing a surgical strategy which include multiple patient-related factors, their own knowledge and expertise, available infrastructure and the infecting organism. Surgeons questioned whether it was appropriate that the two-stage revision remained the best treatment, and some surgeons' willingness to consider more one-stage revisions had increased over recent years and were influenced by growing evidence showing equivalence between surgical techniques, and local observations of successful one-stage revisions. Custom-made articulating spacers was a practice that enabled uncertainty to be managed in the absence of definitive evidence about the superiority of one surgical technique over the other. Surgeons highlighted the need for research evidence to inform practice and thought that a randomised trial to compare treatments was needed. Most surgeons thought that patients who they treated would be eligible for trial participation in instances

  17. The unsuspected prosthetic joint infection : incidence and consequences of positive intra-operative cultures in presumed aseptic knee and hip revisions.

    Science.gov (United States)

    Jacobs, A M E; Bénard, M; Meis, J F; van Hellemondt, G; Goosen, J H M

    2017-11-01

    Positive cultures are not uncommon in cases of revision total knee and hip arthroplasty (TKA and THA) for presumed aseptic causes. The purpose of this study was to assess the incidence of positive intra-operative cultures in presumed aseptic revision of TKA and THA, and to determine whether the presence of intra-operative positive cultures results in inferior survival in such cases. A retrospective cohort study was assembled with 679 patients undergoing revision knee (340 cases) or hip arthroplasty (339 cases) for presumed aseptic causes. For all patients three or more separate intra-operative cultures were obtained. Patients were diagnosed with a previously unsuspected prosthetic joint infection (PJI) if two or more cultures were positive with the same organism. Records were reviewed for demographic details, pre-operative laboratory results and culture results. The primary outcome measure was infection-free implant survival at two years. The incidence of unsuspected PJI was 27 out of 340 (7.9%) in TKA and 41 out of 339 (12.1%) in THA. Following revision TKA, the rate of infection-free implant survival in patients with an unsuspected PJI was 88% (95% confidence intervals (CI) 60 to 97) at two years compared with 98% (95% CI 94 to 99) in patients without PJI (p = 0.001). After THA, the rate of survival was similar in those with unsuspected PJI (92% (95% CI 73 to 98) at two years) and those without (94% (95% CI 89 to 97), p = 0.31). Following revision of TKA and THA for aseptic diagnoses, around 10% of cases were found to have positive cultures. In the knee, such cases had inferior infection-free survival at two years compared with those with negative cultures; there was no difference between the groups following THA. Cite this article: Bone Joint J 2017;99-B:1482-9. ©2017 The British Editorial Society of Bone & Joint Surgery.

  18. Failure of the first step of two-stage revision due to polymicrobial prosthetic joint infection of the hip.

    Science.gov (United States)

    Bozhkova, Svetlana; Tikhilov, Rashid; Labutin, Dmitry; Denisov, Alexey; Shubnyakov, Igor; Razorenov, Vadim; Artyukh, Vasilii; Rukina, Anna

    2016-12-01

    The unsuccessful treatment of prosthetic joint infection (PJI) with two-stage revision leads to infection recurrence. The objectives of the study were to assess the clinical and demographic characteristics of patients with polymicrobial PJI, and to evaluate the role of the microbial profile involved in PJI in the risk of infection recurrence after the first step of two-stage revision surgery. A retrospective analysis of 189 cases of culture-positive PJI following total hip replacement over a 5-year period was performed. The demographic characteristics of patients, clinical symptoms, microbiology cultures of intraoperative biopsies, laboratory values of C-reactive protein (CRP), white blood cell count and erythrocyte sedimentation rate were analyzed. Patients were divided into two groups-135 with monomicrobial and 54 with polymicrobial infection. Of all patients, 68.9 % in the monomicrobial and 83.3 % in the polymicrobial group had a body mass index >25 kg/m 2 (p = 0.05). The median CRP values were 5.7 mg/L (IQR 4.0-10.0 mg/L) in the monomicrobial compared to 8.8 mg/L (IQR 5.0-27 mg/L) in the polymicrobial group (p = 0.01). The percentage of successful outcomes was 27.8 % in patients with microbial associations (p infection recurrence (OR 4.4; 95 % CI 1.18-16.37; p = 0.03). Overweight and obese patients or those with elevated CRP had a greater risk of polymicrobial PJI. They were predisposed to recurrence of infection after the first step of two-stage revision. An unsuccessful outcome was more likely in cases with polymicrobial infection compared to those with monomicrobial infection. In addition, the presence of multidrug-resistant strains of Gram-negative bacteria substantially increased the risk of PJI treatment being unsuccessful. Level III, therapeutic study.

  19. Executive summary of management of prosthetic joint infections. Clinical practice guidelines by the Spanish Society of Infectious Diseases and Clinical Microbiology (SEIMC).

    Science.gov (United States)

    Ariza, Javier; Cobo, Javier; Baraia-Etxaburu, Josu; Benito, Natividad; Bori, Guillermo; Cabo, Javier; Corona, Pablo; Esteban, Jaime; Horcajada, Juan Pablo; Lora-Tamayo, Jaime; Murillo, Oscar; Palomino, Julián; Parra, Jorge; Pigrau, Carlos; Del Pozo, José Luis; Riera, Melchor; Rodríguez, Dolores; Sánchez-Somolinos, Mar; Soriano, Alex; Del Toro, M Dolores; de la Torre, Basilio

    2017-03-01

    The incidence of prosthetic joint infection (PJI) is expected to increase in the coming years. PJI has serious consequences for patients, and high costs for the health system. The complexity of these infections makes it necessary to organize the vast quantity of information published in the last several years. The indications for the choice of a given surgical strategy and the corresponding antimicrobial therapy are specifically reviewed. The authors selected clinically relevant questions and then reviewed the available literature in order to give recommendations according to a pre-determined level of scientific evidence. The more controversial aspects were debated, and the final composition was agreed at an ad hoc meeting. Before its final publication, the manuscript was made available online in order that all SEIMC members were able to read it and make comments and suggestions. Copyright © 2016 Elsevier España, S.L.U. and Sociedad Española de Enfermedades Infecciosas y Microbiología Clínica. All rights reserved.

  20. Accuracy of different diagnostic tests for early, delayed and late prosthetic joint infection.

    Science.gov (United States)

    Fernández-Sampedro, M; Fariñas-Alvarez, C; Garces-Zarzalejo, C; Alonso-Aguirre, M A; Salas-Venero, C; Martínez-Martínez, L; Fariñas, M C

    2017-08-25

    A combination of laboratory, histopathological and microbiological tests for diagnosis of prosthetic joint infection (PJI) have been strongly recommended. This study aims to characterize the accuracy of individual or group tests, such as culture of sonicate fluid, synovial fluid and peri-implant tissue, C-reactive protein (CRP) and histopathology for detection of early, delayed and late PJI. A prospective study of patients undergoing hip or knee arthroplasty from February 2009 to February 2014 was performed in a Spanish tertiary health care hospital. The diagnostic accuracy of the different methods was evaluated constructing receiver-operating-characteristic (ROC) curve areas. One hundred thirty consecutive patients were included: 18 (13.8%) early PJI, 35 (27%) delayed PJI and 77 (59.2%) late PJI. For individual parameters, the area under the ROC curve for peri-implant tissue culture was larger for early (0.917) than for delayed (0.829) and late PJI (0.778), p = 0.033. There was a significantly larger difference for ROC area in the synovial fluid culture for delayed (0.803) than for early (0.781) and late infections (0.679), p = 0.039. The comparison of the areas under the ROC curves for the two microbiological tests showed that sonicate fluid was significantly different from peri-implant tissue in delayed (0.951 vs 0.829, p = 0.005) and late PJI (0.901 vs 0.778, p = 0.000). The conjunction of preoperative parameters, synovial fluid culture and CRP, improved the accuracy for late PJI (p = 0.01). The conjunction of histopathology and sonicate fluid culture increased the area under ROC curve of sonication in early (0.917 vs 1.000); p = 0.06 and late cases (0.901 vs 0.999); p < 0.001. For early PJI, sonicate fluid and peri-implant tissue cultures achieve the same best sensitivity. For delayed and late PJI, sonicate fluid culture is the most sensitive individual diagnostic method. By combining histopathology and peri-implant tissue, all early, 97% of

  1. Experimental measurement of flexion-extension movement in normal and corpse prosthetic elbow joint.

    Science.gov (United States)

    TarniŢă, Daniela; TarniŢă, DănuŢ Nicolae

    2016-01-01

    This paper presents a comparative experimental study of flexion-extension movement in healthy elbow and in the prosthetic elbow joint fixed on an original experimental bench. Measurements were carried out in order to validate the functional morphology and a new elbow prosthesis type ball head. The three-dimensional (3D) model and the physical prototype of our experimental bench used to test elbow endoprosthesis at flexion-extension and pronation-supination movements is presented. The measurements were carried out on a group of nine healthy subjects and on the prosthetic corpse elbow, the experimental data being obtained for flexion-extension movement cycles. Experimental data for the two different flexion-extension tests for the nine subjects and for the corpse prosthetic elbow were acquired using SimiMotion video system. Experimental data were processed statistically. The corresponding graphs were obtained for all subjects in the experimental group, and for corpse prosthetic elbow for both flexion-extension tests. The statistical analysis has proved that the flexion angles of healthy elbows were significantly close to the values measured at the prosthetic elbow fixed on the experimental bench. The studied elbow prosthesis manages to re-establish the mobility for the elbow joint as close to the normal one.

  2. Five-year decreased incidence of surgical site infections following gastrectomy and prosthetic joint replacement surgery through active surveillance by the Korean Nosocomial Infection Surveillance System.

    Science.gov (United States)

    Choi, H J; Adiyani, L; Sung, J; Choi, J Y; Kim, H B; Kim, Y K; Kwak, Y G; Yoo, H; Lee, Sang-Oh; Han, S H; Kim, S R; Kim, T H; Lee, H M; Chun, H K; Kim, J-S; Yoo, J D; Koo, H-S; Cho, E H; Lee, K W

    2016-08-01

    Surveillance of healthcare-associated infection has been associated with a reduction in surgical site infection (SSI). To evaluate the Korean Nosocomial Infection Surveillance System (KONIS) in order to assess its effects on SSI since it was introduced. SSI data after gastrectomy, total hip arthroplasty (THA), and total knee arthroplasty (TKA) between 2008 and 2012 were analysed. The pooled incidence of SSI was calculated for each year; the same analyses were also conducted from hospitals that had participated in KONIS for at least three consecutive years. Standardized SSI rates for each year were calculated by adjusting for SSI risk factors. SSI trends were analysed using the Cochran-Armitage test. The SSI rate following gastrectomy was 3.12% (522/16,918). There was a significant trend of decreased crude SSI rates over five years. This trend was also evident in analysis of hospitals that had participated for more than three years. The SSI rate for THA was 2.05% (157/7656), which decreased significantly from 2008 to 2012. The risk factors for SSI after THA included the National Nosocomial Infections Surveillance risk index, trauma, reoperation, and age (60-69 years). The SSI rate for TKA was 1.90% (152/7648), which also decreased significantly during a period of five years. However, the risk-adjusted analysis of SSI did not show a significant decrease for all surgical procedures. The SSI incidence of gastrectomy and prosthetic joint replacement declined over five years as a result of active surveillance by KONIS. Copyright © 2016 The Healthcare Infection Society. Published by Elsevier Ltd. All rights reserved.

  3. In vitro comparison between α-tocopheryl acetate and α-tocopheryl phosphate against bacteria responsible of prosthetic and joint infections.

    Directory of Open Access Journals (Sweden)

    Alessandro Bidossi

    Full Text Available Biofilm-related infections represent a recurrent problem in the orthopaedic setting. In recent years, great interest was directed towards the identification of novel molecules capable to interfere with pathogens adhesion and biofilm formation on implant surfaces. In this study, two stable forms of α-tocopherol, the hydrophobic acetate ester and the water-soluble phosphate ester, were tested in vitro as coating for titanium prosthesis. Antimicrobial activity against microorganisms responsible of prosthetic and joints infections was assessed by broth microdilution method. In addition, α-tocopherol esters were evaluated for both their ability to hamper bacterial adhesion to and biofilm formation on sandblasted titanium surfaces. Results showed that only α-tocopheryl phosphate displayed antimicrobial activity against the tested strains. Both esters were able to significantly interfere with bacterial adhesion and to prevent biofilm formation, especially by Staphylococcus aureus and Staphylococcus epidermidis. The activity of α-tocopheryl phosphate was greater than that of α-tocopheryl acetate. Alterations at membrane levels have been reported in literature and may be likely responsible for the interference on bacterial adhesion and biofilm formation shown by α-tocopherol esters. Although further studies are needed to better investigate the mechanisms of action and the spectrum of activity of α-tocopherol esters, these characteristics together with the positive effect on wound healing and immune response, make these molecules promising candidate for coating in order to prevent implant-associated infections.

  4. Diagnostic performance of FDG PET or PET/CT in prosthetic infection after arthroplasty: a meta-analysis

    International Nuclear Information System (INIS)

    Jin, H.; Yuan, L.; Li, C.; Kan, Y.; Yang, J.; Hao, R.

    2014-01-01

    The purpose of this study was to systematically review and perform a meta-analysis of published data regarding the diagnostic performance of positron emission tomography (PET) or PET/computed tomography (PET/CT) in prosthetic infection after arthroplasty. A comprehensive computer literature search of studies published through May 31, 2012 regarding PET or PET/CT in patients suspicious of prosthetic infection was performed in PubMed/MEDLINE, Embase and Scopus databases. Pooled sensitivity and specificity of PET or PET/CT in patients suspicious of prosthetic infection on a per prosthesis-based analysis were calculated. The area under the receiver-operating characteristic (ROC) curve was calculated to measure the accuracy of PET or PET/CT in patients with suspicious of prosthetic infection. Fourteen studies comprising 838 prosthesis with suspicious of prosthetic infection after arthroplasty were included in this meta-analysis. The pooled sensitivity of PET or PET/CT in detecting prosthetic infection was 86% (95% confidence interval [CI] 82-90%) on a per prosthesis-based analysis. The pooled specificity of PET or PET/CT in detecting prosthetic infection was 86% (95% CI 83-89%) on a per prosthesis-based analysis. The area under the ROC curve was 0.93 on a per prosthesis-based analysis. In patients suspicious of prosthetic infection, FDG PET or PET/CT demonstrated high sensitivity and specificity. FDG PET or PET/CT are accurate methods in this setting. Nevertheless, possible sources of false positive results and influcing factors should kept in mind.

  5. Diagnostic performance of FDG PET or PET/CT in prosthetic infection after arthroplasty: a meta-analysis.

    Science.gov (United States)

    Jin, H; Yuan, L; Li, C; Kan, Y; Hao, R; Yang, J

    2014-03-01

    The purpose of this study was to systematically review and perform a meta-analysis of published data regarding the diagnostic performance of positron emission tomography (PET) or PET/computed tomography (PET/CT) in prosthetic infection after arthroplasty. A comprehensive computer literature search of studies published through May 31, 2012 regarding PET or PET/CT in patients suspicious of prosthetic infection was performed in PubMed/MEDLINE, Embase and Scopus databases. Pooled sensitivity and specificity of PET or PET/CT in patients suspicious of prosthetic infection on a per prosthesis-based analysis were calculated. The area under the receiver-operating characteristic (ROC) curve was calculated to measure the accuracy of PET or PET/CT in patients with suspicious of prosthetic infection. Fourteen studies comprising 838 prosthesis with suspicious of prosthetic infection after arthroplasty were included in this meta-analysis. The pooled sensitivity of PET or PET/CT in detecting prosthetic infection was 86% (95% confidence interval [CI] 82-90%) on a per prosthesis-based analysis. The pooled specificity of PET or PET/CT in detecting prosthetic infection was 86% (95% CI 83-89%) on a per prosthesis-based analysis. The area under the ROC curve was 0.93 on a per prosthesis-based analysis. In patients suspicious of prosthetic infection, FDG PET or PET/CT demonstrated high sensitivity and specificity. FDG PET or PET/CT are accurate methods in this setting. Nevertheless, possible sources of false positive results and influcing factors should kept in mind.

  6. Prosthetic joint infection: A pluridisciplinary multi-center audit bridging quality of care and outcome.

    Science.gov (United States)

    Roger, P-M; Tabutin, J; Blanc, V; Léotard, S; Brofferio, P; Léculé, F; Redréau, B; Bernard, E

    2015-06-01

    Care to patients with prosthetic joint infections (PJI) is provided after pluridisciplinary collaboration, in particular for complex presentations. Therefore, to carry out an audit in PJI justifies using pluridisciplinary criteria. We report an audit for hip or knee PJI, with emphasis on care homogeneity, length of hospital stay (LOS) and mortality. Fifteen criteria were chosen for quality of care: 5 diagnostic tools, 5 therapeutic aspects, and 5 pluridisciplinary criteria. Among these, 6 were chosen: surgical bacterial samples, surgical strategy, pluridisciplinary discussion, antibiotic treatment, monitoring of antibiotic toxicity, and prevention of thrombosis. They were scored on a scale to 20 points. We included PJI diagnosed between 2010 and 2012 from 6 different hospitals. PJI were defined as complex in case of severe comorbid conditions or multi-drug resistant bacteria, or the need for more than 1 surgery. Eighty-two PJI were included, 70 of which were complex (85%); the median score was 15, with a significant difference among hospitals: from 9 to 17.5 points, P < 0.001. The median LOS was 17 days, and not related to the criterion score; 16% of the patients required intensive care and 13% died. The cure rate was 41%, lost to follow-up 33%, and therapeutic failure 13%. Cure was associated with a higher score than an unfavorable outcome in the univariate analysis (median [range]): 16 [9-18] vs 13 [4-18], P = 0.002. Care to patients with PJI was heterogeneous, our quality criteria being correlated to the outcome. Copyright © 2015 Elsevier Masson SAS. All rights reserved.

  7. Lavage with allicin in combination with vancomycin inhibits biofilm formation by Staphylococcus epidermidis in a rabbit model of prosthetic joint infection.

    Directory of Open Access Journals (Sweden)

    Haohan Zhai

    Full Text Available BACKGROUND AND AIM: The present anti-infection strategy for prosthetic joint infections (PJI includes the use of antibiotics and surgical treatments, but the bacterial eradication rates are still low. One of the major challenges is the formation of biofilm causing poor bacterial eradication. Recently it has been reported that allicin (diallyl thiosulphinate, an antibacterial principle of garlic, can inhibit bacteria adherence and prevent biofilm formation in vitro. However, whether allicin could inhibit biofilm formation in vivo is unknown. The aim of this study was to investigate the effects of allicin on biofilm formation, and whether allicin could potentiate the bactericidal effect of vancomycin in a rabbit PJI model. METHODS: A sterile stainless-steel screw with a sterile ultra-high molecular weight polyethylene washer was inserted into the lateral femoral condyle of the right hind knee joint of rabbit, and 1 mL inoculum containing 104 colony-forming units of Staphylococcus epidermidis was inoculated into the knee joint (n = 32. Fourteen days later, rabbits randomly received one of the following 4 treatments using continuous lavages: normal saline, vancomycin (20 mcg/mL, allicin (4 mg/L, or allicin (4 mg/L plus vancomycin (20 mcg/mL. Three days later, the washer surface biofilm formation was examined by scanning electron microscopy (SEM. The bacterial counts within the biofilm of implanted screws were determined by bacterial culture. RESULTS: The lowest number of viable bacterial counts of Staphylococcus epidermidis recovered from the biofilm was in the rabbits treated with allicin plus vancomycin (P<0.01 vs. all other groups. The biofilm formation was significantly reduced or undetectable by SEM in rabbits receiving allicin or allicin plus vancomycin. CONCLUSION: Intra-articular allicincan inhibit biofilm formation and enhance the bactericidal effect of vancomycin on implant surface in vivo. Allicin in combination with vancomycin may be

  8. Synovial aspiration and serological testing in two-stage revision arthroplasty for prosthetic joint infection: evaluation before reconstruction with a mean follow-up of twenty seven months.

    Science.gov (United States)

    Mühlhofer, Heinrich M L; Knebel, C; Pohlig, Florian; Feihl, Susanne; Harrasser, Norbert; Schauwecker, Johannes; von Eisenhart-Rothe, Rüdiger

    2018-02-01

    The two-stage revision protocol is the gold standard for controlling and treating low-grade prosthetic joint infections of total hip and total knee arthroplasty. The antibiotic pause for diagnostic reasons before reconstruction (stage two) is discussed in relation to the persistence of the infection and the development of resistant bacterial strains. Serological markers and a synovial analysis are commonly used to exclude the persistence of infection. Therefore, we asked (1) is the serological testing of C-reactive protein and leucocytes a valuable tool to predict a persistence of infection? and (2) what is the role of synovial aspiration of Plymethylmethacrylat (PMMA) spacers in hip and knee joints? One hundred twelve patients who were MSIS criteria-positive for a prosthetic joint infection were studied, including 45 total hip arthroplasties (THA) and 67 total knee artrhoplasties (TKA) patients. All patients were treated with a two-stage-protocol using a mobile PMMA spacer after a 14-day antibiotic-free interval, during which we measured serological markers (C-reactive protein and leucocytes) and performed synovial aspiration (white blood cell count, polymorphonuclear cell percentage, and microbiological culture) in these patients and compared the results with those of their long-term-follow-up (mean follow-up 27 months, range 24-36 months). Of the 112 patients, 89 patients (79.5%; 95% CI 72-86.9) exhibited infection control after a two-stage exchange, and we detected most methicillin-resistant, coagulase-negative Staphylococci (CoNS) in cases of a persistent infection. The mean sensitivity of serum C-reactive protein in the patients was 0.43 (range 0.23-0.64), and the mean specificity was 0.73 (range 0.64-0.82). For serum leucocytes, the mean sensitivity was 0.09 (range 0-0.29), and the mean specificity was 0.81 (range 0.7-0.92). The mean sensitivity for the WBC count in the synovial fluid (PMMA spacer aspiration) was 0.1 (range 0-0.29), and the mean

  9. A new three-dimensional, print-on-demand temporomandibular prosthetic total joint replacement system: Preliminary outcomes.

    Science.gov (United States)

    Dimitroulis, George; Austin, Stephen; Sin Lee, Peter Vee; Ackland, David

    2018-05-16

    The aim of this study is to present the preliminary clinical data on the OMX Temporomandibular Joint (TMJ) Prosthetic total joint replacement system. A prospective, cohort, clinical study was undertaken of consecutive adult patients with Category 5 end-stage joint disease who were implanted with the OMX TMJ prosthesis between May 2015 and April 2017. A total of 50 devices were implanted in 38 patients, with 12 patients receiving bilateral prosthetic joints. There were 31 females and 7 males in this cohort, who ranged in age from 20 to 66 years, with a mean of 43.8 years (±14.0 years). Ten of the 50 prosthetic joints (20%) were fully customized, while the remaining were patient matched using virtual planning software. Based on a mean follow-up period of 15.3 months (range 12-24 months) following the TMJ total joint replacement, preliminary results suggest the OMX TMJ prosthesis has made a positive impact on clinical outcomes, with a mean 74.4% reduction in joint pain levels and significant improvements (p < 0.05) in jaw function as measured by the visual analogue scales for mouth opening (30.8%), diet (77.1%), and function (59.2%). No device failures were reported during the study period. This study suggests that the print-on-demand OMX TMJ prosthesis, designed for rapid delivery of both patient-matched and fully customize devices, represents a safe, reliable and versatile implantable joint replacement system for the treatment of category 5 end-stage TMJ disease. Copyright © 2018 European Association for Cranio-Maxillo-Facial Surgery. Published by Elsevier Ltd. All rights reserved.

  10. Multinuclide digital subtraction imaging in symptomatic prostnetic joints

    International Nuclear Information System (INIS)

    Chafetz, N.; Hattner, R.S.; Ruarke, W.C.; Helms, C.A.; Genant, H.K.; Murray, W.R.

    1985-01-01

    One hundred eleven patients with symptomatic prosthetic joints (86 hips, 23 knees, and two shoulders) were evaluated for prosthetic loosening and infection by combined technetium-99m-MDP/gallium-67 digital subtraction imaging. Clinical correlation was based on the assessment of loosening and bacterial cultures obtained at the time of surgery in 54 patients, joint aspiration cultures obtained in 37 patients, and long-term clinical follow-up for greater than 1.5 years in an additional 15 patients. Results revealed an 80-90% predictive value of a positive test for loosening, and a 95% predictive value of a negative test for infection. However, because of the low sensitivities and specificities observed, this approach to the evaluation of symptomatic prosthetic joints does not seem cost effective

  11. Nuclear medicine and the failed joint replacement: Past, present, and future.

    Science.gov (United States)

    Palestro, Christopher J

    2014-07-28

    Soon after the introduction of the modern prosthetic joint, it was recognized that radionuclide imaging provides useful information about these devices. The bone scan was used extensively to identify causes of prosthetic joint failure. It became apparent, however, that although sensitive, regardless of how the images were analyzed or how it was performed, the test was not specific and could not distinguish among the causes of prosthetic failure. Advances in anatomic imaging, notably cross sectional modalities, have facilitated the diagnosis of many, if not most, causes of prosthetic failure, with the important exception of infection. This has led to a shift in the diagnostic paradigm, in which nuclear medicine investigations increasingly have focused on diagnosing infection. The recognition that bone scintigraphy could not reliably diagnose infection led to the development of combined studies, first bone/gallium and subsequently leukocyte/bone and leukocyte/marrow imaging. Labeled leukocyte imaging, combined with bone marrow imaging is the most accurate (about 90%) imaging test for diagnosing joint arthroplasty infection. Its value not withstanding, there are significant disadvantages to this test. In-vivo techniques for labeling leukocytes, using antigranulocyte antibodies have been explored, but have their own limitations and the results have been inconsistent. Fluorodeoxyglucose (FDG)-positron emission tomography (FDG-PET) has been extensively investigated for more than a decade but its role in diagnosing the infected prosthesis has yet to be established. Antimicrobial peptides bind to bacterial cell membranes and are infection specific. Data suggest that these agents may be useful for diagnosing prosthetic joint infection, but large scale studies have yet to be undertaken. Although for many years nuclear medicine has focused on diagnosing prosthetic joint infection, the advent of hybrid imaging with single-photon emission computed tomography

  12. Prolonged suppressive antibiotic therapy for prosthetic joint infection in the elderly: a national multicentre cohort study.

    Science.gov (United States)

    Prendki, V; Ferry, T; Sergent, P; Oziol, E; Forestier, E; Fraisse, T; Tounes, S; Ansart, S; Gaillat, J; Bayle, S; Ruyer, O; Borlot, F; Le Falher, G; Simorre, B; Dauchy, F-A; Greffe, S; Bauer, T; Bell, E N; Martha, B; Martinot, M; Froidure, M; Buisson, M; Waldner, A; Lemaire, X; Bosseray, A; Maillet, M; Charvet, V; Barrelet, A; Wyplosz, B; Noaillon, M; Denes, E; Beretti, E; Berlioz-Thibal, M; Meyssonnier, V; Fourniols, E; Tliba, L; Eden, A; Jean, M; Arvieux, C; Guignery-Kadri, K; Ronde-Oustau, C; Hansmann, Y; Belkacem, A; Bouchand, F; Gavazzi, G; Herrmann, F; Stirnemann, J; Dinh, A

    2017-09-01

    During prosthetic joint infection (PJI), optimal surgical management with exchange of the device is sometimes impossible, especially in the elderly population. Thus, prolonged suppressive antibiotic therapy (PSAT) is the only option to prevent acute sepsis, but little is known about this strategy. We aimed to describe the characteristics, outcome and tolerance of PSAT in elderly patients with PJI. We performed a national cross-sectional cohort study of patients >75 years old and treated with PSAT for PJI. We evaluated the occurrence of events, which were defined as: (i) local or systemic progression of the infection (failure), (ii) death and (iii) discontinuation or switch of PSAT. A total of 136 patients were included, with a median age of 83 years [interquartile range (IQR) 81-88]. The predominant pathogen involved was Staphylococcus (62.1%) (Staphylococcus aureus in 41.7%). A single antimicrobial drug was prescribed in 96 cases (70.6%). There were 46 (33.8%) patients with an event: 25 (18%) with an adverse drug reaction leading to definitive discontinuation or switch of PSAT, 8 (5.9%) with progression of sepsis and 13 died (9.6%). Among patients under follow-up, the survival rate without an event at 2 years was 61% [95% confidence interval (CI): 51;74]. In the multivariate Cox analysis, patients with higher World Health Organization (WHO) score had an increased risk of an event [hazard ratio (HR) = 1.5, p = 0.014], whereas patients treated with beta-lactams are associated with less risk of events occurring (HR = 0.5, p = 0.048). In our cohort, PSAT could be an effective and safe option for PJI in the elderly.

  13. Uptake of radiolabeled leukocytes in prosthetic graft infection

    International Nuclear Information System (INIS)

    Serota, A.I.; Williams, R.A.; Rose, J.G.; Wilson, S.E.

    1981-01-01

    The utility of radionuclide labeled leukocytes in the demonstration of infection within vascular prostheses was examined. The infrarenal aorta was replaced with a 3 cm Dacron graft in 12 dogs. On the third postoperative day, six of the animals received an intravenous injection of 10(8) Staphylococcus aureus. Labeled leukocyte scans were performed at postoperative days one and three, and then weekly for 8 weeks with indium-111 and technetium-99 labeled autologous leukocytes. When scans showed focal uptake of isotope in the area of prosthetic material, the grafts were aseptically excised and cultured on mannitol-salt agar. Both control and infected animals had retroperitoneal isotope activity in the immediate postoperative period that disappeared by the end of the first week. By the eighth postoperative week, all of the animals that received the bacteremic challenge had both radionuclide concentration in the region of the vascular prosthesis and S. aureus cultured subsequently from the perigraft tissues. None of the control animals had either radionuclide or bacteriologic evidence of infection at the eighth postoperative week. The radiolabeled leukocyte scan is a highly sensitive and specific technique, clinically applicable for the diagnosis of vascular prosthetic infections

  14. Diagnosis of Persistent Infection in Prosthetic Two-Stage Exchange: Evaluation of the Effect of Sonication on Antibiotic Release from Bone Cement Spacers.

    Science.gov (United States)

    Mariaux, Sandrine; Furustrand Tafin, Ulrika; Borens, Olivier

    2018-01-01

    Introduction : When treating periprosthetic joint infection with a two-stage procedure, antibiotic-impregnated spacers can be used in the interval between prosthetic removal and reimplantation. In our experience, cultures of sonicated spacers are most often negative. The objective of the study was to assess whether that sonication causes an elution of antibiotics, leading to elevated antibiotic concentrations in the sonication fluid inhibiting bacterial growth and thus causing false-negative cultures. Methods : A prospective monocentric study was performed from September 2014 to March 2016. Inclusion criteria were a two-stage procedure for prosthetic infection and agreement of the patient to participate in the study. Spacers were made of gentamicin-containing cement to which tobramycin and vancomycin were added. Antibiotic concentrations in the sonication fluid were determined by mass-spectometry (LC-MS). Results : 30 patients were identified (15 hip and 14 knee and 1 ankle arthroplasties). No cases of culture positive sonicated spacer fluid were observed in our serie. In the sonication fluid median concentrations of 13.2µg/ml, 392 µg/ml and 16.6 µg/ml were detected for vancomycin, tobramycin and gentamicin, respectively. According to the European Committee on antimicrobial susceptibility testing (EUCAST), these concentrations released from cement spacer during sonication are higher than the minimal inhibitory concentrations (MICs) for most bacteria relevant in prosthetic joint infections. Conclusion: Spacer sonication cultures remained sterile in all of our cases. Elevated concentrations of antibiotics released during sonication could explain partly negative-cultured sonicated spacers. Indeed, the absence of antibiotic free interval during the two-stages can also contribute to false-negative spacers sonicated cultures.

  15. Comparative study of radiography and scintigraphy for loosening and infection of prosthetic hip replacement

    International Nuclear Information System (INIS)

    Park, Mi Sook; Lee, Sun Wha; Choi, Woo Suk; Lim, Joo Won; Song, Han Joon; Ahn, Chi Yul

    1987-01-01

    Prosthetic hip replacement is associated with certain complications which result in a painful hip. Many of these, e. g. prosthetic dislocation, fracture, trochanteric avulsion, and heterotopic calcification are easily diagnosed by conventional radiography. However, radiographic evaluation for infection and/pr loosening of prosthesis as major complications requiring reoperation often contributes little to the resolution of the diagnostic problem. The authors made a comparative study of plain radiography and scintigraphy of 39 cases performed revision at Kyung Hee University Hospital from Sep. '81-to Aug. '86. The results were as follows: 1. In 39 revised prosthetic hip replacement, 26 cases (67%) of loosening without infection and 11 cases (28%) of infection were proven. 2. In loosening of prosthesis, plain radiography showed true positive rate of 76% and true negative rate of 60%, and scintigraphy showed true positive rate of 75% and true negative rate of 95%. 3. In infection of prosthesis, plain radiography revealed true positive rate of 55% and true negative rate of 96%, and scintigraphy revealed true positive rate of 100% and true negative rate of 83%. 4. Scintigraphy and plain radiography were useful as complementary procedure in evaluating and differentiating loosening and/or infection of prosthetic component

  16. 111 In-labeled leukocytes in the detection of prosthetic vascular graft infections

    International Nuclear Information System (INIS)

    Williamson, M.R.; Boyd, C.M.; Read, R.C.; Thompson, B.W.; Barnes, R.W.; Shah, H.R.; Balachandran, S.; Ferris, E.J.

    1986-01-01

    Making a clinical diagnosis of infection in prosthetic vascular grafts is difficult but when undiagnosed, this condition has a high mortality rate. Using Indium-111-labeled white-blood cells, 30 scans were performed in 21 patients suspected of having a prosthetic graft infection. The diagnosis of infected graft was confirmed by surgery in all cases, and lack of infection was established by resolution of symptoms with conservative therapy. Twenty-four hour scans of autologous Indium-111 leukocytes were obtained, and correlative CT studies were done in 11 cases. There were 13 infected grafts at surgery (purulent material present), and scans were positive in all (100% sensitivity); of 17 scans, there were 15 true negatives and two false positives (88% specificity). Using the criteria of gas or fluid around the graft, the sensitivity of CT was only 37% in a small subset of these patients. One-half of the cases in which infection was suspected clinically had no infection and had negative scans. Various types of grafts and graft materials were used, and there was no correlation with presence or absence of infection on the basis of the type of graft. Extragraft infection sites were found in five patients. In conclusion, use of Indium-111 leukocytes has been found to be an accurate and valuable diagnostic method for evaluation of suspected prosthetic vascular graft infection, and to have higher diagnostic accuracy than CT

  17. Detection of low-grade prosthetic joint infections using 99mTc-antigranulocyte SPECT/CT: initial clinical results

    International Nuclear Information System (INIS)

    Graute, Vera; Lehner, Sebastian; Haug, Alexander; Bartenstein, Peter; Hacker, Marcus; Feist, Markus; Mueller, Peter Ernst

    2010-01-01

    Low-grade joint infections are characterized by infiltration of granulocytes, which mediate aspects of inflammatory changes. We evaluated retrospectively the contribution of SPECT/CT as an addition to planar scintigraphy with 99m Tc-labelled antigranulocyte antibodies for diagnosing and localizing low-grade joint infections. Planar scintigraphy using 99m Tc-labelled antigranulocyte BW 250/183 antibodies was performed in 31 patients with suspected joint infections at 5 min, 5 h and 24 h after injection, with additional SPECT/CT performed 6 h after injection. With reference to gold standard clinical data, we assessed the diagnostic sensitivity of scintigraphy alone and in conjunction with SPECT/CT. Joint infections were diagnosed clinically in 9 of the 31 patients (1 hip and 8 knee prostheses). Planar scintigraphy revealed 6 true-positives, 13 true-negatives, 9 false-positives and 3 false-negative results, indicating sensitivity, specificity, positive and negative predictive values of, respectively, 0.66, 0.60, 0.4 and 0.81. With the addition of SPECT images, corresponding sensitivity, specificity, positive and negative predictive values increased to 0.89, 0.45, 0.40 and 0.91. Implementation of fused SPECT/CT led to a further increase to 0.89, 0.73, 0.57 and 0.94. Relative to planar scintigraphy, SPECT with and without CT substantially improved the utility of imaging with 99m Tc-labelled antigranulocyte antibodies for diagnosis and localization of suspected joint infections. Optimal accuracy was obtained through image fusion, which permitted anatomical allocation of foci of pathological tracer accumulation as well as providing information on the extent of the infection. This imaging method seems suited for selection of patients requiring surgical therapy. (orig.)

  18. Predicting Failure in Early Acute Prosthetic Joint Infection Treated With Debridement, Antibiotics, and Implant Retention: External Validation of the KLIC Score.

    Science.gov (United States)

    Löwik, Claudia A M; Jutte, Paul C; Tornero, Eduard; Ploegmakers, Joris J W; Knobben, Bas A S; de Vries, Astrid J; Zijlstra, Wierd P; Dijkstra, Baukje; Soriano, Alex; Wouthuyzen-Bakker, Marjan

    2018-03-27

    Debridement, antibiotics, and implant retention (DAIR) is a widely used treatment modality for early acute prosthetic joint infection (PJI). A preoperative risk score was previously designed for predicting DAIR failure, consisting of chronic renal failure (K), liver cirrhosis (L), index surgery (I), cemented prosthesis (C), and C-reactive protein >115 mg/L (KLIC). The aim of this study was to validate the KLIC score in an external cohort. We retrospectively evaluated patients with early acute PJI treated with DAIR between 2006 and 2016 in 3 Dutch hospitals. Early acute PJI was defined as infection-related death within 60 days after debridement. A total of 386 patients were included. Failure occurred in 148 patients (38.3%). Patients with KLIC scores of ≤2, 2.5-3.5, 4-5, 5.5-6.5, and ≥7 had failure rates of 27.9%, 37.1%, 49.3%, 54.5%, and 85.7%, respectively (P < .001). The receiver-operating characteristic curve showed an area under the curve of 0.64 (95% confidence interval 0.59-0.69). A KLIC score higher than 6 points showed a specificity of 97.9%. The KLIC score is a relatively good preoperative risk score for DAIR failure in patients with early acute PJI and appears to be most useful in clinical practice for patients with low or high KLIC scores. Copyright © 2018 Elsevier Inc. All rights reserved.

  19. Analysis of Interrelationships among Voluntary and Prosthetic Leg Joint Parameters Using Cyclograms.

    Science.gov (United States)

    Jasni, Farahiyah; Hamzaid, Nur Azah; Mohd Syah, Nor Elleeiana; Chung, Tze Y; Abu Osman, Noor Azuan

    2017-01-01

    The walking mechanism of a prosthetic leg user is a tightly coordinated movement of several joints and limb segments. The interaction among the voluntary and mechanical joints and segments requires particular biomechanical insight. This study aims to analyze the inter-relationship between amputees' voluntary and mechanical coupled leg joints variables using cyclograms. From this analysis, the critical gait parameters in each gait phase were determined and analyzed if they contribute to a better powered prosthetic knee control design. To develop the cyclogram model, 20 healthy able-bodied subjects and 25 prosthesis and orthosis users (10 transtibial amputees, 5 transfemoral amputees, and 10 different pathological profiles of orthosis users) walked at their comfortable speed in a 3D motion analysis lab setting. The gait parameters (i.e., angle, moment and power for the ankle, knee and hip joints) were coupled to form 36 cyclograms relationship. The model was validated by quantifying the gait disparities of all the pathological walking by analyzing each cyclograms pairs using feed-forward neural network with backpropagation. Subsequently, the cyclogram pairs that contributed to the highest gait disparity of each gait phase were manipulated by replacing it with normal values and re-analyzed. The manipulated cyclograms relationship that showed highest improvement in terms of gait disparity calculation suggested that they are the most dominant parameters in powered-knee control. In case of transfemoral amputee walking, it was identified using this approach that at each gait sub-phase, the knee variables most responsible for closest to normal walking were: knee power during loading response and mid-stance, knee moment and knee angle during terminal stance phase, knee angle and knee power during pre-swing, knee angle at initial swing, and knee power at terminal swing. No variable was dominant during mid-swing phase implying natural pendulum effect of the lower limb between

  20. Analysis of Interrelationships among Voluntary and Prosthetic Leg Joint Parameters Using Cyclograms

    Directory of Open Access Journals (Sweden)

    Nur Azah Hamzaid

    2017-04-01

    Full Text Available The walking mechanism of a prosthetic leg user is a tightly coordinated movement of several joints and limb segments. The interaction among the voluntary and mechanical joints and segments requires particular biomechanical insight. This study aims to analyze the inter-relationship between amputees' voluntary and mechanical coupled leg joints variables using cyclograms. From this analysis, the critical gait parameters in each gait phase were determined and analyzed if they contribute to a better powered prosthetic knee control design. To develop the cyclogram model, 20 healthy able-bodied subjects and 25 prosthesis and orthosis users (10 transtibial amputees, 5 transfemoral amputees, and 10 different pathological profiles of orthosis users walked at their comfortable speed in a 3D motion analysis lab setting. The gait parameters (i.e., angle, moment and power for the ankle, knee and hip joints were coupled to form 36 cyclograms relationship. The model was validated by quantifying the gait disparities of all the pathological walking by analyzing each cyclograms pairs using feed-forward neural network with backpropagation. Subsequently, the cyclogram pairs that contributed to the highest gait disparity of each gait phase were manipulated by replacing it with normal values and re-analyzed. The manipulated cyclograms relationship that showed highest improvement in terms of gait disparity calculation suggested that they are the most dominant parameters in powered-knee control. In case of transfemoral amputee walking, it was identified using this approach that at each gait sub-phase, the knee variables most responsible for closest to normal walking were: knee power during loading response and mid-stance, knee moment and knee angle during terminal stance phase, knee angle and knee power during pre-swing, knee angle at initial swing, and knee power at terminal swing. No variable was dominant during mid-swing phase implying natural pendulum effect of the

  1. Multidisciplinary Treatment Approach for Prosthetic Vascular Graft Infection in the Thoracic Aortic Area

    Science.gov (United States)

    Watanabe, Yoshinori

    2015-01-01

    Prosthetic vascular graft infection in the thoracic aortic area is a rare but serious complication. Adequate management of the complication is essential to increase the chance of success of open surgery. While surgical site infection is suggested as the root cause of the complication, it is also related to decreased host tolerance, especially as found in elderly patients. The handling of prosthetic vascular graft infection has been widely discussed to date. This paper mainly provides a summary of literature reports published within the past 5 years to discuss issues related to multidisciplinary treatment approaches, including surgical site infection, timing of onset, diagnostic methods, causative pathogens, auxiliary diagnostic methods, antibiotic treatment, anti-infective structures of vascular prostheses, surgical treatment, treatment strategy against infectious aortic aneurysms, future surgical treatment, postoperative systemic therapy, and antimicrobial stewardship. A thorough understanding of these issues will enable us to prevent prosthetic vascular graft infection in the thoracic aortic area as far as possible. In the event of its occurrence, the early introduction of appropriate treatment is expected to cure the disease without worsening of the underlying pathological condition. PMID:26356686

  2. Accuracy of CT-guided joint aspiration in patients with suspected infection status post-total hip arthroplasty

    Energy Technology Data Exchange (ETDEWEB)

    Tomas, Xavier; Garcia-Diez, Ana Isabel; Pomes, Jaime [Universidad de Barcelona, Department of Radiology, Hospital Clinic, Barcelona (Spain); Bori, Guillem; Garcia, Sebastian; Gallart, Xavier; Martinez, Juan Carlos; Riba, Josep [Universidad de Barcelona, Department of Orthopaedics, Hospital Clinic, Barcelona (Spain); Soriano, Alex; Mensa, Josep [Universidad de Barcelona, Department of Infectious Diseases, Hospital Clinic, Barcelona (Spain); Rios, Jose [Statistical Unit de Suport a la Estadistica I Metodologia IDIBAPS, Barcelona (Spain); Almela, Manel [Universidad de Barcelona, Department of Microbiology, Hospital Clinic, Barcelona (Spain)

    2011-01-15

    To determine the accuracy of guided computed tomography aspiration in the detection of septic hip prosthesis before surgery. Sixty-three patients (35 women and 28 men; age range, 29-86 years; mean age, 71 years) with clinically suspected septic hip prosthesis were prospectively studied with independent review board (IRB) approval. Volume and microbiological cultures of aspirated fluid and several computed tomography imaging findings such as periprosthetic fluid collections, prosthetic acetabular malposition, and heterotopic ossification were analyzed. All patients underwent revision surgery and infection was finally diagnosed in 33 patients. Statistical comparative analysis was performed comparing computed tomography aspiration and surgical findings (95% CI; level of significance at P = 0.05 two-sided) with 70% sensitivity, 100% specificity, 84% accuracy, 100% positive predictive value, and 75% negative predictive value. Using Fisher's exact test, the presence of periprosthetic fluid collections (P = 0.001), prosthetic acetabular malposition (P = 0.025) and aspirated fluid volume (P = 0.009) were significantly higher in infected than in non-infected prostheses, whereas heterotopic ossification was not (P = 0.429). Computed tomography aspiration is accurate to preoperatively diagnose septic hip prosthesis on the basis of volume and bacterial cultures of aspirated joint fluid. Furthermore, imaging findings such as periprosthetic fluid collections and prosthetic acetabular malposition strongly suggest infected prosthesis. (orig.)

  3. Accuracy of CT-guided joint aspiration in patients with suspected infection status post-total hip arthroplasty

    International Nuclear Information System (INIS)

    Tomas, Xavier; Garcia-Diez, Ana Isabel; Pomes, Jaime; Bori, Guillem; Garcia, Sebastian; Gallart, Xavier; Martinez, Juan Carlos; Riba, Josep; Soriano, Alex; Mensa, Josep; Rios, Jose; Almela, Manel

    2011-01-01

    To determine the accuracy of guided computed tomography aspiration in the detection of septic hip prosthesis before surgery. Sixty-three patients (35 women and 28 men; age range, 29-86 years; mean age, 71 years) with clinically suspected septic hip prosthesis were prospectively studied with independent review board (IRB) approval. Volume and microbiological cultures of aspirated fluid and several computed tomography imaging findings such as periprosthetic fluid collections, prosthetic acetabular malposition, and heterotopic ossification were analyzed. All patients underwent revision surgery and infection was finally diagnosed in 33 patients. Statistical comparative analysis was performed comparing computed tomography aspiration and surgical findings (95% CI; level of significance at P = 0.05 two-sided) with 70% sensitivity, 100% specificity, 84% accuracy, 100% positive predictive value, and 75% negative predictive value. Using Fisher's exact test, the presence of periprosthetic fluid collections (P = 0.001), prosthetic acetabular malposition (P = 0.025) and aspirated fluid volume (P = 0.009) were significantly higher in infected than in non-infected prostheses, whereas heterotopic ossification was not (P = 0.429). Computed tomography aspiration is accurate to preoperatively diagnose septic hip prosthesis on the basis of volume and bacterial cultures of aspirated joint fluid. Furthermore, imaging findings such as periprosthetic fluid collections and prosthetic acetabular malposition strongly suggest infected prosthesis. (orig.)

  4. Comparative study of radiography and scintigraphy for loosening and infection of prosthetic hip replacement

    Energy Technology Data Exchange (ETDEWEB)

    Park, Mi Sook; Lee, Sun Wha; Choi, Woo Suk; Lim, Joo Won; Song, Han Joon; Ahn, Chi Yul [College of Medicine, Kyung Hee University, Seoul (Korea, Republic of)

    1987-10-15

    Prosthetic hip replacement is associated with certain complications which result in a painful hip. Many of these, e. g. prosthetic dislocation, fracture, trochanteric avulsion, and heterotopic calcification are easily diagnosed by conventional radiography. However, radiographic evaluation for infection and/pr loosening of prosthesis as major complications requiring reoperation often contributes little to the resolution of the diagnostic problem. The authors made a comparative study of plain radiography and scintigraphy of 39 cases performed revision at Kyung Hee University Hospital from Sep. '81-to Aug. '86. The results were as follows: 1. In 39 revised prosthetic hip replacement, 26 cases (67%) of loosening without infection and 11 cases (28%) of infection were proven. 2. In loosening of prosthesis, plain radiography showed true positive rate of 76% and true negative rate of 60%, and scintigraphy showed true positive rate of 75% and true negative rate of 95%. 3. In infection of prosthesis, plain radiography revealed true positive rate of 55% and true negative rate of 96%, and scintigraphy revealed true positive rate of 100% and true negative rate of 83%. 4. Scintigraphy and plain radiography were useful as complementary procedure in evaluating and differentiating loosening and/or infection of prosthetic component.

  5. Indium-111 leukocyte localization in infected prosthetic graft

    Energy Technology Data Exchange (ETDEWEB)

    Purnell, G.L.; Walker, C.W.; Allison, J.W.; Dalrymple, G.V. (Univ. of Arkansas for Medical Sciences, Little Rock (USA))

    1990-08-01

    Infective endocarditis can be difficult to prove, even in the face of strong clinical suspicion. A case in which standard methods of diagnosis failed to demonstrate endocarditis in a patient with recurrent Staphylococcus aureus bacteremia and porcine aortic valve is reported. An In-111 labelled leukocyte SPECT study demonstrated uptake in the aortic root and leaflets, and autopsy demonstrated vegetations on the leaflets. In-111 may prove useful in demonstrating endocarditis in patients with prosthetic valve infection.

  6. Indium-111 leukocyte localization in infected prosthetic graft

    International Nuclear Information System (INIS)

    Purnell, G.L.; Walker, C.W.; Allison, J.W.; Dalrymple, G.V.

    1990-01-01

    Infective endocarditis can be difficult to prove, even in the face of strong clinical suspicion. A case in which standard methods of diagnosis failed to demonstrate endocarditis in a patient with recurrent Staphylococcus aureus bacteremia and porcine aortic valve is reported. An In-111 labelled leukocyte SPECT study demonstrated uptake in the aortic root and leaflets, and autopsy demonstrated vegetations on the leaflets. In-111 may prove useful in demonstrating endocarditis in patients with prosthetic valve infection

  7. Differential bacterial load on components of total knee prosthesis in patients with prosthetic joint infection.

    Science.gov (United States)

    Holinka, Johannes; Pilz, Magdalena; Hirschl, Alexander M; Graninger, Wolfgang; Windhager, Reinhard; Presterl, Elisabeth

    2012-10-01

    The purpose of our study was to evaluate and quantify the bacterial adherence on different components of total knee prosthesis with the sonication culture method. Explanted components of all patients with presumptive prosthetic or implant infection were treated by sonication separately in sterile containers to dislodge the adherent bacteria from the surfaces and cultured. The bacterial load of the different knee components (femur, tibia, PE-inlay and patella) was evaluated by counting of colony-forming units (CFU) dislodged from the components surfaces using the sonication culture method. Overall, 27 patients had positive sonication cultures of explanted total knee prostheses. Microorganisms were detected from 88 of 100 explanted components. Twenty femoral components were culture positive and 7 negative, 23 tibial components as well as 23 polyethylene (PE) platforms had positive microorganism detection from the surface. Staphylococcus epidermidis adhered to the highest number of components whereas Staphylococcus aureus yielded the highest load of CFU in the sonication cultures. Although not significant, PE-inlays and tibial components were most often affected. The highest CFU count was detected in polyethylene components. The sonication culture method is a reliable method to detect bacteria from the components. Additionally, the results demonstrate that bacterial adherence is not affecting a single component of knee prosthesis only. Thus, in septic revision surgery partial prosthetic exchange or exchange of single polyethylene components alone may be not sufficient.

  8. One- and two-stage surgical revision of peri-prosthetic joint infection of the hip: a pooled individual participant data analysis of 44 cohort studies.

    Science.gov (United States)

    Kunutsor, Setor K; Whitehouse, Michael R; Blom, Ashley W; Board, Tim; Kay, Peter; Wroblewski, B Mike; Zeller, Valérie; Chen, Szu-Yuan; Hsieh, Pang-Hsin; Masri, Bassam A; Herman, Amir; Jenny, Jean-Yves; Schwarzkopf, Ran; Whittaker, John-Paul; Burston, Ben; Huang, Ronald; Restrepo, Camilo; Parvizi, Javad; Rudelli, Sergio; Honda, Emerson; Uip, David E; Bori, Guillem; Muñoz-Mahamud, Ernesto; Darley, Elizabeth; Ribera, Alba; Cañas, Elena; Cabo, Javier; Cordero-Ampuero, José; Redó, Maria Luisa Sorlí; Strange, Simon; Lenguerrand, Erik; Gooberman-Hill, Rachael; Webb, Jason; MacGowan, Alasdair; Dieppe, Paul; Wilson, Matthew; Beswick, Andrew D

    2018-04-05

    One-stage and two-stage revision strategies are the two main options for treating established chronic peri-prosthetic joint infection (PJI) of the hip; however, there is uncertainty regarding which is the best treatment option. We aimed to compare the risk of re-infection between the two revision strategies using pooled individual participant data (IPD). Observational cohort studies with PJI of the hip treated exclusively by one- or two-stage revision and reporting re-infection outcomes were retrieved by searching MEDLINE, EMBASE, Web of Science, The Cochrane Library, and the WHO International Clinical Trials Registry Platform; as well as email contact with investigators. We analysed IPD of 1856 participants with PJI of the hip from 44 cohorts across four continents. The primary outcome was re-infection (recurrence of infection by the same organism(s) and/or re-infection with a new organism(s)). Hazard ratios (HRs) for re-infection were calculated using Cox proportional frailty hazards models. After a median follow-up of 3.7 years, 222 re-infections were recorded. Re-infection rates per 1000 person-years of follow-up were 16.8 (95% CI 13.6-20.7) and 32.3 (95% CI 27.3-38.3) for one-stage and two-stage strategies respectively. The age- and sex-adjusted HR of re-infection for two-stage revision was 1.70 (0.58-5.00) when compared with one-stage revision. The association remained consistently absent after further adjustment for potential confounders. The HRs did not vary importantly in clinically relevant subgroups. Analysis of pooled individual patient data suggest that a one-stage revision strategy may be as effective as a two-stage revision strategy in treating PJI of the hip.

  9. Validation of the diagnosis 'prosthetic joint infection' in the Danish Hip Arthroplasty Register

    DEFF Research Database (Denmark)

    Gundtoft, P H; Pedersen, Alma Becic; Schønheyder, H C

    2016-01-01

    and followed them until first-time revision, death, emigration or until 31 December 2012. Revision for PJI, as registered in the DHR, was validated against a benchmark which included information from microbiology databases, prescription registers, clinical biochemistry registers and clinical records. We......AIMS: The purpose of this study was to validate the diagnosis of periprosthetic joint infection (PJI) in the Danish Hip Arthroplasty Register (DHR). PATIENTS AND METHODS: We identified a cohort of patients from the DHR who had undergone primary total hip arthroplasty (THA) since 1 January 2005...... the validity of the diagnosis of PJI and should enable future register-based studies. Cite this article: Bone Joint J 2016;98-B:320-5....

  10. Detection of low-grade prosthetic joint infections using {sup 99m}Tc-antigranulocyte SPECT/CT: initial clinical results

    Energy Technology Data Exchange (ETDEWEB)

    Graute, Vera; Lehner, Sebastian; Haug, Alexander; Bartenstein, Peter; Hacker, Marcus [University of Munich, Department of Nuclear Medicine, Munich (Germany); Feist, Markus; Mueller, Peter Ernst [University of Munich, Department of Orthopedic Medicine, Munich (Germany)

    2010-09-15

    Low-grade joint infections are characterized by infiltration of granulocytes, which mediate aspects of inflammatory changes. We evaluated retrospectively the contribution of SPECT/CT as an addition to planar scintigraphy with {sup 99m}Tc-labelled antigranulocyte antibodies for diagnosing and localizing low-grade joint infections. Planar scintigraphy using {sup 99m}Tc-labelled antigranulocyte BW 250/183 antibodies was performed in 31 patients with suspected joint infections at 5 min, 5 h and 24 h after injection, with additional SPECT/CT performed 6 h after injection. With reference to gold standard clinical data, we assessed the diagnostic sensitivity of scintigraphy alone and in conjunction with SPECT/CT. Joint infections were diagnosed clinically in 9 of the 31 patients (1 hip and 8 knee prostheses). Planar scintigraphy revealed 6 true-positives, 13 true-negatives, 9 false-positives and 3 false-negative results, indicating sensitivity, specificity, positive and negative predictive values of, respectively, 0.66, 0.60, 0.4 and 0.81. With the addition of SPECT images, corresponding sensitivity, specificity, positive and negative predictive values increased to 0.89, 0.45, 0.40 and 0.91. Implementation of fused SPECT/CT led to a further increase to 0.89, 0.73, 0.57 and 0.94. Relative to planar scintigraphy, SPECT with and without CT substantially improved the utility of imaging with {sup 99m}Tc-labelled antigranulocyte antibodies for diagnosis and localization of suspected joint infections. Optimal accuracy was obtained through image fusion, which permitted anatomical allocation of foci of pathological tracer accumulation as well as providing information on the extent of the infection. This imaging method seems suited for selection of patients requiring surgical therapy. (orig.)

  11. Diagnosis Of Persistent Infection In Prosthetic Two-Stage Exchange: PCR analysis of Sonication fluid From Bone Cement Spacers.

    Science.gov (United States)

    Mariaux, Sandrine; Tafin, Ulrika Furustrand; Borens, Olivier

    2017-01-01

    Introduction: When treating periprosthetic joint infections with a two-stage procedure, antibiotic-impregnated spacers are used in the interval between removal of prosthesis and reimplantation. According to our experience, cultures of sonicated spacers are most often negative. The objective of our study was to investigate whether PCR analysis would improve the detection of bacteria in the spacer sonication fluid. Methods: A prospective monocentric study was performed from September 2014 to January 2016. Inclusion criteria were two-stage procedure for prosthetic infection and agreement of the patient to participate in the study. Beside tissues samples and sonication, broad range bacterial PCRs, specific S. aureus PCRs and Unyvero-multiplex PCRs were performed on the sonicated spacer fluid. Results: 30 patients were identified (15 hip, 14 knee and 1 ankle replacements). At reimplantation, cultures of tissue samples and spacer sonication fluid were all negative. Broad range PCRs were all negative. Specific S. aureus PCRs were positive in 5 cases. We had two persistent infections and four cases of infection recurrence were observed, with bacteria different than for the initial infection in three cases. Conclusion: The three different types of PCRs did not detect any bacteria in spacer sonication fluid that was culture-negative. In our study, PCR did not improve the bacterial detection and did not help to predict whether the patient will present a persistent or recurrent infection. Prosthetic 2-stage exchange with short interval and antibiotic-impregnated spacer is an efficient treatment to eradicate infection as both culture- and molecular-based methods were unable to detect bacteria in spacer sonication fluid after reimplantation.

  12. Diagnosis of arterial prosthetic graft infection by 111In oxine white blood cell scans

    International Nuclear Information System (INIS)

    McKeown, P.P.; Miller, D.C.; Jamieson, S.W.; Mitchell, R.S.; Reitz, B.A.; Olcott, C.; Mehigan, J.T.; Silberstein, R.J.; McDougall, I.R.

    1982-01-01

    Early and accurate diagnosis of infected prosthetic arterial grafts is difficult, despite the application of diverse diagnostic modalities. Delay in making the diagnosis is largely responsible for the high amputation and mortality rates associated with this complication. In nine patients with suspected graft infections, 111 In white blood cell scanning was useful and accurate. Graft infection was proved in five cases and ruled out in three. One false-positive scan was due to a sigmoid diverticular abscess overlying the graft. 111 In white blood cell scans may improve the accuracy of diagnosing infected prosthetic grafts, which may result in better limb and patient salvage rates

  13. Prosthetic graft infection: limitations of indium white blood cell scanning

    International Nuclear Information System (INIS)

    Brunner, M.C.; Mitchell, R.S.; Baldwin, J.C.; James, D.R.; Olcott, C. IV; Mehigan, J.T.; McDougall, I.R.; Miller, D.C.

    1986-01-01

    The lack of a rapid, noninvasive, and accurate method to confirm or rule out prosthetic graft infection continues to constitute a compelling and vexing clinical problem. A host of adjunctive diagnostic techniques has been used in the past, but early promising results subsequently have usually not yielded acceptable sensitivity (reflecting false negatives) and specificity (reflecting false positive) data. White blood cell (WBC) indium 111 scanning has recently been added to this list. The utility and accuracy of 111 In WBC scans were assessed by retrospective review of WBC scan results in 70 patients undergoing evaluation for possible prosthetic graft infection over a 7-year period. Operative and autopsy data (mean follow-up, 18 months for survivors with negative scans) were used to confirm the 22 positive, 45 negative, and three equivocal WBC scans. The false positive rate (+/- 70% confidence limits) was 36% +/- 6% (n = 8) among the 22 patients with positive scans (44% +/- 6% [11 of 25] if the three equivocal scans are included as false positive), yielding a specificity of 85% +/- 5% and an overall accuracy rate of 88% +/- 4% (80% +/- 5% and 84% +/- 5%, respectively, if the three equivocal cases are considered as false positive). All three patients with equivocal scans ultimately were judged not to have prosthetic graft infection. As implied by the high accuracy rate, the sensitivity of the test was absolute (100% [14 of 14]); there were no false negative results

  14. Bio-absorbable antibiotic impregnated beads for the treatment of prosthetic vascular graft infections.

    Science.gov (United States)

    Genovese, Elizabeth A; Avgerinos, Efthymios D; Baril, Donald T; Makaroun, Michel S; Chaer, Rabih A

    2016-12-01

    There is limited investigation into the use of bio-absorbable antibiotic beads for the treatment of prosthetic vascular graft infections. Our goal was to investigate the rates of infection eradication, graft preservation, and limb salvage in patients who are not candidates for graft explant or extensive reconstruction. A retrospective review of patients implanted with antibiotic impregnated bio-absorbable calcium sulfate beads at a major university center was conducted. Six patients with prosthetic graft infections were treated with bio-absorbable antibiotics beads from 2012-2014. Grafts included an aortobifemoral, an aorto-hepatic/superior mesenteric artery, and four extra-anatomic bypasses. Pathogens included Gram-positive and Gram-negative bacteria. Half of the patients underwent graft explant with reconstruction and half debridement of the original graft, all with antibiotic bead placement around the graft. Mean follow-up was 7.3 ± 8.3 months; all patients had infection resolution, healed wounds, and 100% graft patency, limb salvage, and survival. This report details the successful use of bio-absorbable antibiotic beads for the treatment prosthetic vascular graft infections in patients at high risk for graft explant or major vascular reconstruction. At early follow-up, we demonstrate successful infection suppression, graft preservation, and limb salvage with the use of these beads in a subset of vascular patients. © The Author(s) 2016.

  15. Bio-absorbable antibiotic impregnated beads for the treatment of prosthetic vascular graft infections

    Science.gov (United States)

    Genovese, Elizabeth A; Avgerinos, Efthymios D; Baril, Donald T; Makaroun, Michel S; Chaer, Rabih A

    2017-01-01

    Objective There is limited investigation into the use of bio-absorbable antibiotic beads for the treatment of prosthetic vascular graft infections. Our goal was to investigate the rates of infection eradication, graft preservation, and limb salvage in patients who are not candidates for graft explant or extensive reconstruction. Methods A retrospective review of patients implanted with antibiotic impregnated bio-absorbable calcium sulfate beads at a major university center was conducted. Results Six patients with prosthetic graft infections were treated with bio-absorbable antibiotics beads from 2012–2014. Grafts included an aortobifemoral, an aorto-hepatic/superior mesenteric artery, and four extra-anatomic bypasses. Pathogens included Gram-positive and Gram-negative bacteria. Half of the patients underwent graft explant with reconstruction and half debridement of the original graft, all with antibiotic bead placement around the graft. Mean follow-up was 7.3±8.3 months; all patients had infection resolution, healed wounds, and 100% graft patency, limb salvage, and survival. Conclusion This report details the successful use of bio-absorbable antibiotic beads for the treatment prosthetic vascular graft infections in patients at high risk for graft explant or major vascular reconstruction. At early follow-up, we demonstrate successful infection suppression, graft preservation, and limb salvage with the use of these beads in a subset of vascular patients. PMID:26896286

  16. FDG and FDG-labelled leucocyte PET/CT in the imaging of prosthetic joint infection

    Energy Technology Data Exchange (ETDEWEB)

    Aksoy, Sabire Yilmaz; Asa, Sertac; Ozhan, Meftune; Sager, M.S.; Halac, Metin; Kabasakal, Levent; Soenmezoglu, Kerim; Kanmaz, Bedii [University of Istanbul, Department of Nuclear Medicine, Cerrahpasa Medical Faculty, Aksaray, Istanbul (Turkey); Ocak, Meltem [University of Istanbul, Department of Pharmaceutical Technology, Faculty of Pharmacy, Istanbul (Turkey); Erkan, Melih Engin [Duzce University School of Medicine, Department of Nuclear Medicine, Duzce (Turkey)

    2014-03-15

    The demand for arthroplasty is rapidly growing as a result of the ageing of the population. Although complications such as heterotrophic ossification, fracture and dislocation are relatively rare, differentiating aseptic loosening, the most common complication of arthroplasty from infection, is a major challenge for clinicians. Radionuclide imaging is currently the imaging modality of choice since it is not affected by orthopaedic hardware. Whereas FDG PET/CT imaging has been widely used in periprosthetic infection, it cannot discriminate aseptic from septic inflammation. In this study we aimed to evaluate the role of FDG PET/CT and FDG-labelled leucocyte PET/CT in the diagnosis of periprosthetic infection. Of 54 patients with painful joint arthroplasty who were imaged by FDG PET/CT for diagnosis of periprosthetic infection examined, 46 (36 women, 10 men; mean age 61.04 ± 12.2 years, range 32 - 89 years) with 54 painful joint prostheses (19 hip, 35 knee) with grade 2 (above liver uptake) FDG accumulation on FDG PET/CT were included in the study and these 46 patients also underwent FDG-labelled leucocyte PET/CT. Final diagnoses were made by histopathological-microbiological culture or clinical follow-up. The final diagnosis showed infection in 15 (28 %) and aseptic loosening in 39 (72 %) of the 54 prostheses. FDG PET/CT was found to have a positive predictive value of 28 % (15/54). Since patients with no FDG uptake on FDG PET/CT were excluded from the study, the sensitivity, specificity, negative predictive value and accuracy could not be calculated. The sensitivity, specificity, and positive and negative predictive values of FDG-labelled leucocyte PET/CT were 93.3 % (14/15), 97.4 % (38/39), 93.3 % and 97.4 %, respectively. Since FDG is not specific to infection, the specificity of FDG PET/CT was very low. FDG-labelled leucocyte PET/CT with its high specificity may be a useful method and better than labelled leucocyte scintigraphy in periprosthetic infection

  17. Bone and joint infections by Mucorales, Scedosporium, Fusarium and even rarer fungi.

    Science.gov (United States)

    Koehler, Philipp; Tacke, Daniela; Cornely, Oliver A

    2016-01-01

    Mucorales, Scedosporium and Fusarium species are rarely considered as cause for bone and joint infections. However, these moulds are emerging as important fungal pathogens in immunocompromised and immunocompetent patients. Typical pre-disposing host conditions are immunosuppression and diabetes. Most common causative pathogens are Mucorales followed by Scedosporium and Fusarium. Acremonium and Phialemonium species are rare but some case reports exist. MRI is the gold standard imaging technique. Tissue specimens obtained as aspirates, imaging guided biopsy or open surgery need mycological and histopathological work-up for genus and species identification. Multimodal treatment strategies combine surgical debridement, drainage of joints or abscesses, removal of infected prosthetic joints and systemic antifungals. The treatment of mucormycosis is polyene based and may be combined with either posaconazole or - in rare cases - caspofungin. As Scedosporium species are intrinsically resistant to polyenes and azoles show absence of in vitro activity, voriconazole plus synergistic treatment regimens become the therapeutic standard. In fusariosis, fungal susceptibility is virtually impossible to predict, so that combination treatment of voriconazole and lipid-based amphotericin B should be the first-line strategy while susceptibility results are pending. In the absence of randomized controlled trials, infections due to the above moulds should be registered, e.g. in the registries of the European Confederation of Medical Mycology (ECMM).

  18. Agreement between pre-operative and intra-operative bacteriological samples in 85 chronic peri-prosthetic infections.

    Science.gov (United States)

    Matter-Parrat, V; Ronde-Oustau, C; Boéri, C; Gaudias, J; Jenny, J-Y

    2017-04-01

    Whether pre-operative microbiological sampling contributes to the management of chronic peri-prosthetic infection remains controversial. We assessed agreement between the results of pre-operative and intra-operative samples in patients undergoing single-stage prosthesis exchange to treat chronic peri-prosthetic infection. Agreement between pre-operative and intra-operative samples exceeds 75% in patients undergoing single-stage exchange of a hip or knee prosthesis to treat chronic peri-prosthetic infection. This single-centre retrospective study included 85 single-stage prosthesis exchange procedures in 82 patients with chronic peri-prosthetic infection at the hip or knee. Agreement between pre-operative and intra-operative sample results was evaluated. Changes to the initial antibiotic regimen made based on the intra-operative sample results were recorded. Of 149 pre-operative samples, 109 yielded positive cultures, in 75/85 cases. Of 452 intra-operative samples, 354 yielded positive cultures, in 85/85 cases. Agreement was complete in 54 (63%) cases and partial in 9 (11%) cases; there was no agreement in the remaining 22 (26%) cases. The complete agreement rate was significantly lower than 75% (P=0.01). The initial antibiotic regimen was inadequate in a single case. Pre-operative sampling may contribute to the diagnosis of peri-prosthetic infection but is neither necessary nor sufficient to confirm the diagnosis and identify the causative agent. The spectrum of the initial antibiotic regimen cannot be safely narrowed based on the pre-operative sample results. We suggest the routine prescription of a probabilistic broad-spectrum antibiotic regimen immediately after the prosthesis exchange, even when a pathogen was identified before surgery. IV, retrospective study. Copyright © 2017 Elsevier Masson SAS. All rights reserved.

  19. Total hip replacement infected with Mycobacterium tuberculosis complicated by Addison disease and psoas muscle abscess: a case report

    Directory of Open Access Journals (Sweden)

    De Nardo Pasquale

    2012-01-01

    Full Text Available Abstract Introduction Prosthetic joint infection due to Mycobacterium tuberculosis is occasionally encountered in clinical practice. To the best of our knowledge, this is the first report of a prosthetic joint infection due to Mycobacterium tuberculosis complicated by psoas abscesses and secondary Addison disease. Case presentation A 67-year-old immunocompetent Caucasian woman underwent total left hip arthroplasty because of osteoarthritis. After 18 months, she underwent arthroplasty revision for a possible prosthetic infection. Periprosthetic tissue specimens for bacteria were negative, and empirical antibiotic therapy was unsuccessful. She was then admitted to our department because of complications arising 22 months after arthroplasty. A physical examination revealed a sinus tract overlying her left hip and skin and mucosal pigmentation. Her levels of C-reactive protein, basal cortisol, adrenocorticotropic hormone, and sodium were out of normal range. Results of the tuberculin skin test and QuantiFERON-TB Gold test were positive. Computed tomography revealed a periprosthetic abscess and the inclusion of the left psoas muscle. Results of microbiological tests were negative, but polymerase chain reaction of a specimen taken from the hip fistula was positive for Mycobacterium tuberculosis. Our patient's condition was diagnosed as prosthetic joint infection and muscle psoas abscess due to Mycobacterium tuberculosis and secondary Addison disease. She underwent standard treatment with rifampicin, ethambutol, isoniazid, and pyrazinamide associated with hydrocortisone and fludrocortisone. At 15 months from the beginning of therapy, she was in good clinical condition and free of symptoms. Conclusions Prosthetic joint infection with Mycobacterium tuberculosis is uncommon. A differential diagnosis of tuberculosis should be considered when dealing with prosthetic joint infection, especially when repeated smears and histology examination from infected

  20. Deep prosthetic joint infection: a qualitative study of the impact on patients and their experiences of revision surgery

    Science.gov (United States)

    Blom, Ashley W; Whitehouse, Michael R; Gooberman-Hill, Rachael

    2015-01-01

    Objectives Around 1% of patients who have a hip replacement have deep prosthetic joint infection (PJI) afterwards. PJI is often treated with antibiotics plus a single revision operation (1-stage revision), or antibiotics plus a 2-stage revision process involving more than 1 operation. This study aimed to characterise the impact and experience of PJI and treatment on patients, including comparison of 1-stage with 2-stage revision treatment. Design Qualitative semistructured interviews with patients who had undergone surgical revision treatment for PJI. Patients were interviewed between 2 weeks and 12 months postdischarge. Data were audio-recorded, transcribed, anonymised and analysed using a thematic approach, with 20% of transcripts double-coded. Setting Patients from 5 National Health Service (NHS) orthopaedic departments treating PJI in England and Wales were interviewed in their homes (n=18) or at hospital (n=1). Participants 19 patients participated (12 men, 7 women, age range 56–88 years, mean age 73.2 years). Results Participants reported receiving between 1 and 15 revision operations after their primary joint replacement. Analysis indicated that participants made sense of their experience through reference to 3 key phases: the period of symptom onset, the treatment period and protracted recovery after treatment. By conceptualising their experience in this way, and through themes that emerged in these periods, they conveyed the ordeal that PJI represented. Finally, in light of the challenges of PJI, they described the need for support in all of these phases. 2-stage revision had greater impact on participants’ mobility, and further burdens associated with additional complications. Conclusions Deep PJI impacted on all aspects of patients’ lives. 2-stage revision had greater impact than 1-stage revision on participants’ well-being because the time in between revision procedures meant long periods of immobility and related psychological distress

  1. Cryopreserved Cadaveric Arterial Allograft for Arterial Reconstruction in Patients with Prosthetic Infection.

    Science.gov (United States)

    Lejay, Anne; Delay, Charline; Girsowicz, Elie; Chenesseau, Bettina; Bonnin, Emilie; Ghariani, Mohamed-Zied; Thaveau, Fabien; Georg, Yannick; Geny, Bernard; Chakfe, Nabil

    2017-11-01

    The aim of this study was to report outcomes of cryopreserved arterial allografts used as a vascular substitute in the setting of prosthetic material infection. A retrospective analysis of prospectively collected data was conducted including all consecutive interventions performed with cryopreserved arterial allografts used for vascular reconstruction in the setting of prosthetic material infection between January 2005 and December 2014. Five year outcomes included allograft related re-interventions, survival, primary patency, and limb salvage rates. Fifty-three procedures were performed using cryopreserved allografts for vascular prosthetic infection: 25 procedures (47%) were performed at aorto-iliac level (Group 1) and 28 procedures (53%) at peripheral level (Group 2). The mean follow-up was 52 months. Five year allograft related re-intervention was 55% in Group 1 (6 allograft ruptures and 5 allograft aneurysm degenerations) and 33% in Group 2 (2 allograft ruptures and 7 allograft aneurysm degenerations). Five year survival was 40% and 68%, primary patency was 89% and 59% and limb salvage was 100% and 89% for Group 1 and 2 respectively. Use of cryopreserved arterial allografts provides acceptable results but is tempered by suboptimal 5 year outcomes with high re-intervention rates. Copyright © 2017 European Society for Vascular Surgery. Published by Elsevier Ltd. All rights reserved.

  2. First Case Report of a Late Onset Knee Periprosthetic Joint Infection Caused by Lactococcus garvieae

    Directory of Open Access Journals (Sweden)

    V.-I. Neagoe

    2016-01-01

    Full Text Available Lactococcus garvieae is known as a Gram-positive, catalase-negative, and facultatively anaerobic fish pathogen. The association between Lactococcus spp. and human infectious diseases is described as being mainly associated with lumbar osteomyelitis, hepatic abscess, and infective endocarditis. In the literature of orthopedic post-prosthetic infections, L. garvieae was associated with a case of hip prosthetic infection in a fishmonger woman. We present the case of a 79-year-old male patient with multiple comorbidities, who is admitted to our center with a 5-day history of pain, swelling, and motility disorder of the right knee by the presence of a bicondylar knee replacement surgery, which was performed due to gonarthrosis 17 years ago. The radiographies of the right knee revealed no signs of displacement or loosening of the prothesis. After multiple radical debridements including VAC therapy and targeted antibiotic therapy we have managed to defeat the infection without exchange arthroplasty. Although we could not demonstrate the source of infection, we can only presume that in our case the source of infection was represented by the ingestion of possibly contaminated food. The patient had a habit of eating Nile perch fish (Lates niloticus every 4 weeks. We illustrated once more the possibility of a late onset L. garvieae related orthopedic periprosthetic joint infection by multiple comorbidities.

  3. A computational method for comparing the behavior and possible failure of prosthetic implants

    Energy Technology Data Exchange (ETDEWEB)

    Nielsen, C.; Hollerbach, K.; Perfect, S.; Underhill, K.

    1995-05-01

    Prosthetic joint implants currently in use exhibit high Realistic computer modeling of prosthetic implants provides an opportunity for orthopedic biomechanics researchers and physicians to understand possible in vivo failure modes, without having to resort to lengthy and costly clinical trials. The research presented here is part of a larger effort to develop realistic models of implanted joint prostheses. The example used here is the thumb carpo-metacarpal (cmc) joint. The work, however, can be applied to any other human joints for which prosthetic implants have been designed. Preliminary results of prosthetic joint loading, without surrounding human tissue (i.e., simulating conditions under which the prosthetic joint has not yet been implanted into the human joint), are presented, based on a three-dimensional, nonlinear finite element analysis of three different joint implant designs.

  4. Cryopreserved Human Allografts for the Reconstruction of Aortic and Peripheral Prosthetic Graft Infection.

    Science.gov (United States)

    Bossi, Matteo; Tozzi, Matteo; Franchin, Marco; Ferraro, Stefania; Rivolta, Nicola; Ferrario, Massimo; Guttadauro, Chiara; Castelli, Patrizio; Piffaretti, Gabriele

    2017-12-25

    Background : This study aimed to present cases with cryopreserved human allografts (CHAs) for vascular reconstruction in both aortic and peripheral infected prosthetic grafts. Materials and Methods : This is a single center, observational descriptive study with retrospective analysis. In all cases, the infected prosthetic graft material was completely removed. At discharge, patients were administered anticoagulants. Follow-up examinations included clinical visits, echo-color-Doppler ultrasounds, or computed tomography angiography within 30 days and at 3, 6, and 12 months after the treatment, and then twice per year. Results : We treated 21 patients (90% men, n=19) with the mean age of 71±12 years and mean interval between the initial operation and replacement with CHA of 30 months [range, 1-216; interquartile range (IQR), 2-36]. In-hospital mortality was 14% (n=3); no CHA-related complication led to death. Limb salvage was 100%. No patient was lost at the median follow-up of 14 months (range, 2-61; IQR, 6-39). No rupture, aneurysmal degeneration, or re-infection occurred. Estimated freedom from CHA-related adverse events (95% confidence interval, 43-63) was 95% at 3 years. Conclusion : In our experience, CHAs are a viable option for prosthetic graft infections and provide satisfactory clinical results and favorable stability because of a very low rate of CHA-related adverse events during follow-up.

  5. Cost-effectiveness of antibiotic prophylaxis for dental patients with prosthetic joints: Comparisons of antibiotic regimens for patients with total hip arthroplasty.

    Science.gov (United States)

    Skaar, Daniel D; Park, Taehwan; Swiontkowski, Marc F; Kuntz, Karen M

    2015-11-01

    Clinician uncertainty concerning the need for antibiotic prophylaxis to prevent prosthetic joint infection (PJI) after undergoing dental procedures persists. Improved understanding of the potential clinical and economic risks and benefits of antibiotic prophylaxis will help inform the debate and facilitate the continuing evolution of clinical management guidelines for dental patients with prosthetic joints. The authors developed a Markov decision model to compare the lifetime cost-effectiveness of alternative antibiotic prophylaxis strategies for dental patients aged 65 years who had undergone total hip arthroplasty (THA). On the basis of the authors' interpretation of previous recommendations from the American Dental Association and American Academy of Orthopaedic Surgeons, they compared the following strategies: no prophylaxis, prophylaxis for the first 2 years after arthroplasty, and lifetime prophylaxis. A strategy of foregoing antibiotic prophylaxis before dental visits was cost-effective and resulted in lower lifetime accumulated costs ($11,909) and higher accumulated quality-adjusted life years (QALYs) (12.375) when compared with alternative prophylaxis strategies. The results of Markov decision modeling indicated that a no-antibiotic prophylaxis strategy was cost-effective for dental patients who had undergone THA. These results support the findings of case-control studies and the conclusions of an American Dental Association Council on Scientific Affairs report that questioned general recommendations for antibiotic prophylaxis before dental procedures. The results of cost-effectiveness decision modeling support the contention that routine antibiotic prophylaxis for dental patients with total joint arthroplasty should be reconsidered. Copyright © 2015 American Dental Association. Published by Elsevier Inc. All rights reserved.

  6. Mesofluidic controlled robotic or prosthetic finger

    Science.gov (United States)

    Lind, Randall F; Jansen, John F; Love, Lonnie J

    2013-11-19

    A mesofluidic powered robotic and/or prosthetic finger joint includes a first finger section having at least one mesofluidic actuator in fluid communication with a first actuator, a second mesofluidic actuator in fluid communication with a second actuator and a second prosthetic finger section pivotally connected to the first finger section by a joint pivot, wherein the first actuator pivotally cooperates with the second finger to provide a first mechanical advantage relative to the joint point and wherein the second actuator pivotally cooperates with the second finger section to provide a second mechanical advantage relative to the joint point.

  7. Role of Tc-99m Sulesomab in the diagnosis of bone and joint infections

    International Nuclear Information System (INIS)

    Iyengar, K.P.; Nadkarni, J.B.; Vinjamuri, S.

    2005-01-01

    Confirming the presence of deep-seated infection in the bones and joints can be difficult, especially when routine laboratory tests and plain radiographs are inconclusive. The aim of this study was to assess the role of Tc-99m labelled anti-granulocyte monoclonal antibody Fab' fragment (Sulesomab) in bone and joint infection. Scans of 95 patients with suspected skeletal/ joint infection were studied and correlated with clinical information. Referrals consisted of suspected infection in prosthetic total joint replacements (38), long bones (32), primary joints (12) and feet (13). There were 48 female and 47 male referrals with a mean age of 60 rears (Range= 16 to 89 years). Results of routine haemogram (ESR, CRP and full blood count), plain radiographs, relevant microbiology, culture and /or histology were collected in all patients. All patients had positive Tc-99m MDP bone scan prior to Tc-99m Sulesomab scintigraphy. Patients were classified into true positives, true negatives, false positives and false negatives on the basis of final diagnosis arrived at by conclusive microbiology, surgery, complementary investigations like CT/MRI and clinical follow-up. Fifty-eight out of 95 patients had normal or equivocal blood test results. Plain radiographs revealed no abnormality or were inconclusive of infection in more than half of the patients. The Tc-99m Sulesomab scans were found to be positive in 38 patients and 57 had normal scans. Outcome classification revealed 29 true positives, 56 true negatives, 9 false positives and one false negative with an overall sensitivity of 96.66 %, specificity of 86.15 % and negative predictive value of 98.24%. Individual sensitivity, specificity and diagnostic accuracy of each category were compared. The diagnostic accuracy was found to be the highest for long bone infections (96.87%) and least for primary joint infections (83.33%). Overall the sensitivities were better than specificity in all categories. We therefore conclude that Tc

  8. The Clinical usefulness of 99mTc HMPAO Leukocyte/99mTc phytate bone marrow scintigraphy for diagnosis of prosthetic knee infection: A preliminary study

    International Nuclear Information System (INIS)

    Jung, Kyung Pyo; Park, Ji Sun; Lee, Ah Young; Choi, Su Jung; Lee, Seok Mo; Bae, Sang Kyun

    2012-01-01

    The preferred radionuclide imaging procedure for diagnosing prosthetic joint infection is combined radiolabeled leukocyte/ 99mT c sulfur colloid bone marrow scintigraphy, which has an accuracy of over 90%. Unfortunately, sulfur colloid is no longer available in South Korea. in this study, we evaluated the usefulness of 99mT c phytate, a substitute for 99mT c sulfur colloid, when combined with radiolabeled leukocyte scintigraphy in suspected prosthetic knee infections. Eleven patients (nine women, two men; mean age 72±6 years) with painful knee prostheses and a suspicion of infection underwent both 99mT c phytate bone marrow scintigraphy (BMS). The combined images were interpreted as positive for infection when radioactivity in the LS at the sits of clinical interest clearly exceeded that of the BMS (discordant); they were interpreted as negative when the increased activity in the LS was consistent with an increased activity in the BMS(concordant). The final diagnosis was made with microbiological or intraoperative findings and a clinical follow up of at least 12 months. Five of eleven patients were diagnosed as having an infected prosthesis. The overall sensitivity, specificity, specificity, positive predictive value (PPV), negative predictive value (NPV), and diagnostic accuracy of the combined LS/BMS were 100%, 83%, 83%, 100% and 91%, respectively. We find that combined 99mT c HMPAO LS/ 99mT c phytate BMS shows comparable diagnostic performance to other studies utilizing sulfur colloid. Combined 99mT c HMPAO LS/ 99mT c phytate BMS is therefore expected to be an acceptable alternative to combined radiolabeled LS/ 99ms ulfur colloid BMS for diagnosing prosthetic knee infections

  9. A Modern Approach to Preventing Prosthetic Joint Infections.

    Science.gov (United States)

    Papas, Paraskevi Vivian; Congiusta, Dominick; Scuderi, Giles R; Cushner, Fred D

    2018-02-28

    Total knee arthroplasty (TKA) is recognized as one of the most successful surgical procedures performed today. One of the most common and dreaded complications of TKA is postoperative infection. To prevent infections, it is critical to identify patients at high risk through analyzing their risk factors, and help in addressing them prior to surgery. The effort to prevent infection must be carried through every step of the surgical process, from preoperative counseling to intraoperative measures and postoperative protocols. Hair removal, the application of antiseptics, the utilization of antibiotics, barbed sutures, smart dressings, and antibacterial washes are some of the avenues surgeons may explore to help prevent infection. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.

  10. Prosthetic vascular graft infection through a median sternotomy: a multicentre review †.

    Science.gov (United States)

    Oda, Tatsuya; Minatoya, Kenji; Kobayashi, Junjiro; Okita, Yutaka; Akashi, Hidetoshi; Tanaka, Hiroyuki; Kawaharada, Nobuyoshi; Saiki, Yoshikatsu; Kuniyoshi, Yukio; Nishimura, Kunihiro

    2015-06-01

    The aim of this study is to analyse the treatment outcomes of thoracic prosthetic graft infection. A retrospective chart review was conducted at six hospitals and included the records of 68 patients treated for postoperative prosthetic vascular graft infection (mean age: 62.3 ± 15.1, male 51) from January 2000 to December 2013. The number of patients and the locations of the treated infections were as follows: 13 for aortic root, 16 for ascending aorta, 35 for aortic arch and 4 for aortic root to arch. In-hospital infection occurred in 43 patients and after discharge in 25. The mean follow-up time was 2.0 ± 2.3 years. The follow-up rate was 94.1%. The most commonly isolated micro-organism was Staphylococcus aureus (72.1%). Rereplacement of infectious graft was performed in 18 patients (Dacron graft in 12, homograft in 4 and rifampicin-bonded Dacron graft in 2). The overall hospital mortality rate was 35.3% (24/68). The mortality rate among the patients with graft rereplacement was 33.3% (6/18), with pedicled muscle flaps or pedicled omental flaps to cover the graft 25.9% (7/27), with irrigation 55.0% (11/20) and on antibiotic therapy only 0% (0/3). Our multivariate analysis demonstrated that the risk factors of hospital death increased in the absence of pedicled flaps (muscle or omentum) to cover the graft (P = 0.001), age over 55 (P = 0.003), time from onset of initial operation prosthetic vascular graft infection have not been satisfactory. However, the use of pedicled muscle or omental flaps to cover the graft could improve the outcomes. © The Author 2015. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.

  11. F-18-Fluorodeoxyglucose Positron Emission Tomography/CT Scanning in Diagnosing Vascular Prosthetic Graft Infection

    NARCIS (Netherlands)

    Saleem, Ben R.; Pol, Robert A.; Slart, Riemer H. J. A.; Reijnen, Michel M. P. J.; Zeebregts, Clark J.

    2014-01-01

    Vascular prosthetic graft infection (VPGI) is a severe complication after vascular surgery. CT-scan is considered the diagnostic tool of choice in advanced VPGI. The incidence of a false-negative result using CT is relatively high, especially in the presence of low-grade infections.

  12. Healthcare-associated prosthetic heart valve, aortic vascular graft, and disseminated Mycobacterium chimaera infections subsequent to open heart surgery.

    Science.gov (United States)

    Kohler, Philipp; Kuster, Stefan P; Bloemberg, Guido; Schulthess, Bettina; Frank, Michelle; Tanner, Felix C; Rössle, Matthias; Böni, Christian; Falk, Volkmar; Wilhelm, Markus J; Sommerstein, Rami; Achermann, Yvonne; Ten Oever, Jaap; Debast, Sylvia B; Wolfhagen, Maurice J H M; Brandon Bravo Bruinsma, George J; Vos, Margreet C; Bogers, Ad; Serr, Annerose; Beyersdorf, Friedhelm; Sax, Hugo; Böttger, Erik C; Weber, Rainer; van Ingen, Jakko; Wagner, Dirk; Hasse, Barbara

    2015-10-21

    We identified 10 patients with disseminated Mycobacterium chimaera infections subsequent to open-heart surgery at three European Hospitals. Infections originated from the heater-cooler unit of the heart-lung machine. Here we describe clinical aspects and treatment course of this novel clinical entity. Interdisciplinary care and follow-up of all patients was documented by the study team. Patients' characteristics, clinical manifestations, microbiological findings, and therapeutic measures including surgical reinterventions were reviewed and treatment outcomes are described. The 10 patients comprise a 1-year-old child and nine adults with a median age of 61 years (range 36-76 years). The median duration from cardiac surgery to diagnosis was 21 (range 5-40) months. All patients had prosthetic material-associated infections with either prosthetic valve endocarditis, aortic graft infection, myocarditis, or infection of the prosthetic material following banding of the pulmonary artery. Extracardiac manifestations preceded cardiovascular disease in some cases. Despite targeted antimicrobial therapy, M. chimaera infection required cardiosurgical reinterventions in eight patients. Six out of 10 patients experienced breakthrough infections, of which four were fatal. Three patients are in a post-treatment monitoring period. Healthcare-associated infections due to M. chimaera occurred in patients subsequent to cardiac surgery with extracorporeal circulation and implantation of prosthetic material. Infections became clinically apparent after a time lag of months to years. Mycobacterium chimaera infections are easily missed by routine bacterial diagnostics and outcome is poor despite long-term antimycobacterial therapy, probably because biofilm formation hinders eradication of pathogens. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2015. For permissions please email: journals.permissions@oup.com.

  13. Synovial fluid white cell count and histopathological examination of periprosthetic tissue samples (frozen and permanent sections in the diagnosis of prosthetic knee infection

    Directory of Open Access Journals (Sweden)

    Obada B.

    2017-02-01

    Full Text Available The aim of the study was to determine prospectively the importance of synovial fluid white cell count and intraoperative frozen and permanent sections analysis (number of polymorphonuclear leukocytes per high-power field in the diagnosis of septic total knee arthroplasty. There were studied prospectively 72 patients who needed a revision total knee arthroplasty between 2013-2015. 30 patients were diagnosed with prosthetic joint infection due to high rates of ESR (93% and CRP (90% and preoperative positive culture from aspirated synovial fluid and 42 patients were considered to have aseptic failure according to negative preoperative culture from joint aspirate. For all the patients was analysed synovial fluid white cell count and histopathological aspect of intraoperative frozen and permanent sections of periprosthetic tissue. The results showed a median value of 13800 of sinovial white cells count for infected knee and 92 for noninfected knee. 90% of the patients with joint infection had more than 5 polymorphonuclear leukocytes per high power field on intraoperative frozen sections and 83% on permanent sections. None of the patients from aseptic group had more than 5 polymorphonuclear leukocytes per field on permanent sections. The erythrocyte sedimentation rate and C-reactive protein level can be supplemented with cultures of aspirated joint fluid and fluid white cell count to confirm the diagnosis of periprosthetic infection. When the preoperative diagnosis remain unclear, the histological examination of frozen or permanent sections of periprosthetic tissue with at least 5 polymorphonuclear leukocytes per high power field, is predictive for the presence of infection.

  14. 99mTc-leukocyte scintigraphy in prosthetic vascular graft infections

    International Nuclear Information System (INIS)

    Vorne, M.; Laitinen, J.; Lehtonen, J.; Toivio, I.; Mokka, R.; Soini, I.

    1989-01-01

    The aim of this study was to determine the diagnostic value of scintigraphy with 99m Tc-HMPAO-labelled leukocytes for the detection of prosthetic vascular graft infection. 51 scans were recorded in 19 patients with suspected vascular graft infection and 8 control patients. Three-phase scanning was used at 0.5, 3-6 and 18-24 h. 13 vascular graft infections (10 early, 3 late) were found. 12 of these healed with antibiotics and only one patient with late infection had to be reoperated. None of them died during the follow-up period. The sensitivity was 100% and the specificity 96%. 99m Tc-leukocyte scintigraphy seems a useful tool to detect vascular graft infection and to differentiate it from infections elsewhere. The results suggest that the incidence of vascular graft infection may be greater, and the mortality rate lower, than supposed before. (orig.) [de

  15. Short- versus long-duration levofloxacin plus rifampicin for acute staphylococcal prosthetic joint infection managed with implant retention: a randomised clinical trial.

    Science.gov (United States)

    Lora-Tamayo, Jaime; Euba, Gorane; Cobo, Javier; Horcajada, Juan Pablo; Soriano, Alex; Sandoval, Enrique; Pigrau, Carles; Benito, Natividad; Falgueras, Luis; Palomino, Julián; Del Toro, María Dolores; Jover-Sáenz, Alfredo; Iribarren, José Antonio; Sánchez-Somolinos, Mar; Ramos, Antonio; Fernández-Sampedro, Marta; Riera, Melchor; Baraia-Etxaburu, Josu Mirena; Ariza, Javier

    2016-09-01

    Levofloxacin plus rifampicin (L+R) is the treatment of choice for acute staphylococcal prosthetic joint infection (PJI) managed with debridement and implant retention (DAIR). Long courses have been empirically recommended, but some studies have suggested that shorter treatments could be as effective. Our aim was to prove that a short treatment schedule was non-inferior to the standard long schedule. An open-label, multicentre, randomised clinical trial (RCT) was performed. Patients with an early post-surgical or haematogenous staphylococcal PJI, managed with DAIR and initiated on L+R were randomised to receive 8 weeks of treatment (short schedule) versus a long schedule (3 months or 6 months for hip or knee prostheses, respectively). The primary endpoint was cure rate. From 175 eligible patients, 63 were included (52% women; median age, 72 years): 33 patients (52%) received the long schedule and 30 (48%) received the short schedule. There were no differences between the two groups except for a higher rate of polymicrobial infection in the long-schedule group (27% vs. 7%; P = 0.031). Median follow-up was 540 days. In the intention-to-treat analysis, cure rates were 58% and 73% in patients receiving the long and short schedules, respectively (difference -15.7%, 95% CI -39.2% to 7.8%). Forty-four patients (70%) were evaluable per-protocol: cure rates were 95.0% and 91.7% for the long and short schedules, respectively (difference 3.3%, 95% CI -11.7% to 18.3%). This is the first RCT suggesting that 8 weeks of L+R could be non-inferior to longer standard treatments for acute staphylococcal PJI managed with DAIR. Copyright © 2016 Elsevier B.V. and International Society of Chemotherapy. All rights reserved.

  16. The “true” incidence of surgically treated deep prosthetic joint infection after 32,896 primary total hip arthroplasties

    Science.gov (United States)

    Gundtoft, Per Hviid; Overgaard, Søren; Schønheyder, Henrik Carl; Møller, Jens Kjølseth; Kjærsgaard-Andersen, Per; Pedersen, Alma Becic

    2015-01-01

    Background and purpose It has been suggested that the risk of prosthetic joint infection (PJI) in patients with total hip arthroplasty (THA) may be underestimated if based only on arthroplasty registry data. We therefore wanted to estimate the “true” incidence of PJI in THA using several data sources. Patients and methods We searched the Danish Hip Arthroplasty Register (DHR) for primary THAs performed between 2005 and 2011. Using the DHR and the Danish National Register of Patients (NRP), we identified first revisions for any reason and those that were due to PJI. PJIs were also identified using an algorithm incorporating data from microbiological, prescription, and clinical biochemistry databases and clinical findings from the medical records. We calculated cumulative incidence with 95% confidence interval. Results 32,896 primary THAs were identified. Of these, 1,546 had first-time revisions reported to the DHR and/or the NRP. For the DHR only, the 1- and 5-year cumulative incidences of PJI were 0.51% (0.44–0.59) and 0.64% (0.51–0.79). For the NRP only, the 1- and 5-year cumulative incidences of PJI were 0.48% (0.41–0.56) and 0.57% (0.45–0.71). The corresponding 1- and 5-year cumulative incidences estimated with the algorithm were 0.86% (0.77–0.97) and 1.03% (0.87–1.22). The incidences of PJI based on the DHR and the NRP were consistently 40% lower than those estimated using the algorithm covering several data sources. Interpretation Using several available data sources, the “true” incidence of PJI following primary THA was estimated to be approximately 40% higher than previously reported by national registries alone. PMID:25637247

  17. Conservative treatment of vascular prosthetic graft infection is associated with high mortality

    NARCIS (Netherlands)

    Saleem, Ben R.; Meetwaldt, Robbert; Tielliu, Ignace F. J.; Verhoeven, Eric L. G.; van den Dungen, Jan J. A. M.; Zeebregts, Clark J.

    BACKGROUND: The aim of this study was to identify patient-related and/or disease-related factors that influence outcomes in patients with vascular prosthetic graft infections. METHODS: Through the hospital patient administration system, between January 1997 and December 2007, a total of 44 patients

  18. Antibiotic treatment of biofilm infections

    DEFF Research Database (Denmark)

    Ciofu, Oana; Rojo-Molinero, Estrella; Macià, María D.

    2017-01-01

    Bacterial biofilms are associated with a wide range of infections, from those related to exogenous devices, such as catheters or prosthetic joints, to chronic tissue infections such as those occurring in the lungs of cystic fibrosis patients. Biofilms are recalcitrant to antibiotic treatment due ...

  19. The role of bone scanning, gallium and indium imaging in infection

    International Nuclear Information System (INIS)

    Mido, K.; Navarro, D.A.; Segall, G.M.; McDougall, I.R.

    1987-01-01

    Nuclear medicine studies have considerable value in diagnosing infectious conditions in the skeleton. In this chapter the authors discuss acute infections of bone and joints separately. The section on acute osteomyelitis covers radiopharmaceuticals, methods, experimental models and the results of clinical series. Acute infections of joints is discussed with attention to radiopharmaceuticals, methods and results. The diagnosis of acute infection is prosthetic joints is treated separately. The evaluation of chronic bone infections is described briefly

  20. Welding of Prosthetic Alloys

    Directory of Open Access Journals (Sweden)

    Wojciechowska M.

    2015-04-01

    Full Text Available This paper presents the techniques of joining metal denture elements, used in prosthetic dentistry: the traditional soldering technique with a gas burner and a new technique of welding with a laser beam; the aim of the study was to make a comparative assessment of the quality of the joints in view of the possibility of applying them in prosthetic structures. Fractographic examinations were conducted along with tensile strength and impact strength tests, and the quality of the joints was assessed compared to the solid metal. The experiments have shown that the metal elements used to make dentures, joined by the technique which employs a laser beam, have better strength properties than those achieved with a gas burner.

  1. How Many Samples and How Many Culture Media To Diagnose a Prosthetic Joint Infection: a Clinical and Microbiological Prospective Multicenter Study.

    Science.gov (United States)

    Bémer, Pascale; Léger, Julie; Tandé, Didier; Plouzeau, Chloé; Valentin, Anne Sophie; Jolivet-Gougeon, Anne; Lemarié, Carole; Kempf, Marie; Héry-Arnaud, Geneviève; Bret, Laurent; Juvin, Marie Emmanuelle; Giraudeau, Bruno; Corvec, Stéphane; Burucoa, Christophe

    2016-02-01

    Although numerous perioperative samples and culture media are required to diagnose prosthetic joint infection (PJI), their exact number and types have not yet been definitely determined with a high level of proof. We conducted a prospective multicenter study to determine the minimal number of samples and culture media required for accurate diagnosis of PJI. Over a 2-year period, consecutive patients with clinical signs suggesting PJI were included, with five perioperative samples per patient. The bacteriological and PJI diagnosis criteria were assessed using a random selection of two, three, or four samples and compared with those obtained using the recommended five samples (references guidelines). The results obtained with two or three culture media were then compared with those obtained with five culture media for both criteria. The times-to-positivity of the different culture media were calculated. PJI was confirmed in 215/264 suspected cases, with a bacteriological criterion in 192 (89%). The PJI was monomicrobial (85%) or polymicrobial (15%). Percentages of agreement of 98.1% and 99.7%, respectively, for the bacteriological criterion and confirmed PJI diagnosis were obtained when four perioperative samples were considered. The highest percentages of agreement were obtained with the association of three culture media, a blood culture bottle, a chocolate agar plate, and Schaedler broth, incubated for 5, 7, and 14 days, respectively. This new procedure leads to significant cost saving. Our prospective multicenter study showed that four samples seeded on three culture media are sufficient for diagnosing PJI. Copyright © 2016, American Society for Microbiology. All Rights Reserved.

  2. Amputation and Prosthetics

    Science.gov (United States)

    ... All Topics A-Z Videos Infographics Symptom Picker Anatomy Bones Joints Muscles Nerves Vessels Tendons About Hand Surgery What is a Hand Surgeon? What is a Hand Therapist? Media Find a Hand Surgeon Home Anatomy Amputation and Prosthetics Email to a friend * required ...

  3. The Clinical usefulness of {sup 99mT}c HMPAO Leukocyte/{sup 99mT}c phytate bone marrow scintigraphy for diagnosis of prosthetic knee infection: A preliminary study

    Energy Technology Data Exchange (ETDEWEB)

    Jung, Kyung Pyo; Park, Ji Sun; Lee, Ah Young; Choi, Su Jung; Lee, Seok Mo; Bae, Sang Kyun [Inje Univ., Pusan Paik Hospital, Pusan (Korea, Republic of)

    2012-12-15

    The preferred radionuclide imaging procedure for diagnosing prosthetic joint infection is combined radiolabeled leukocyte/{sup 99mT}c sulfur colloid bone marrow scintigraphy, which has an accuracy of over 90%. Unfortunately, sulfur colloid is no longer available in South Korea. in this study, we evaluated the usefulness of {sup 99mT}c phytate, a substitute for {sup 99mT}c sulfur colloid, when combined with radiolabeled leukocyte scintigraphy in suspected prosthetic knee infections. Eleven patients (nine women, two men; mean age 72{+-}6 years) with painful knee prostheses and a suspicion of infection underwent both {sup 99mT}c phytate bone marrow scintigraphy (BMS). The combined images were interpreted as positive for infection when radioactivity in the LS at the sits of clinical interest clearly exceeded that of the BMS (discordant); they were interpreted as negative when the increased activity in the LS was consistent with an increased activity in the BMS(concordant). The final diagnosis was made with microbiological or intraoperative findings and a clinical follow up of at least 12 months. Five of eleven patients were diagnosed as having an infected prosthesis. The overall sensitivity, specificity, specificity, positive predictive value (PPV), negative predictive value (NPV), and diagnostic accuracy of the combined LS/BMS were 100%, 83%, 83%, 100% and 91%, respectively. We find that combined {sup 99mT}c HMPAO LS/{sup 99mT}c phytate BMS shows comparable diagnostic performance to other studies utilizing sulfur colloid. Combined {sup 99mT}c HMPAO LS/{sup 99mT}c phytate BMS is therefore expected to be an acceptable alternative to combined radiolabeled LS/{sup 99ms}ulfur colloid BMS for diagnosing prosthetic knee infections.

  4. Microbiology and management of joint and bone infections due to anaerobic bacteria.

    Science.gov (United States)

    Brook, Itzhak

    2008-03-01

    To describes the microbiology, diagnosis, and management of septic arthritis and osteomyelitis due to anaerobic bacteria. The predominant anaerobes in arthritis are anaerobic Gram-negative bacilli (AGNB) including the Bacteroides fragilis group, Fusobacterium spp., Peptostreptococcus spp., and Propionibacterium acnes. Infection with P. acnes is associated with a prosthetic joint, previous surgery, and trauma. B. fragilis group is associated with distant infection, Clostridium spp. with trauma, and Fusobacterium spp. with oropharyngeal infection. Most cases of anaerobic arthritis, in contrast to anaerobic osteomyelitis, involved a single isolate, and most cases are secondary to hematogenous spread. The predominant anaerobes in osteomyelitis are Bacteroides, Peptostreptococcus, Fusobacterium, and Clostridium spp. as well as P. acnes. Conditions predisposing to bone infections are vascular disease, bites, contiguous infection, peripheral neuropathy, hematogenous spread, and trauma. Pigmented Prevotella and Porphyromonas spp. are mostly isolated in skull and bite infections, members of the B. fragilis group in hand and feet infections, and Fusobacterium spp. in skull, bite, and hematogenous long bone infections. Many patients with osteomyelitis due to anaerobic bacteria have evidence of an anaerobic infection elsewhere in the body that is the source of the organisms involved in the osteomyelitis. Treatment of arthritis and osteomyelitis involving anaerobic bacteria includes symptomatic therapy, immobilization in some cases, adequate drainage of purulent material, and antibiotic therapy effective against these organisms. Anaerobic bacteria can cause septic arthritis and osteomyelitis. Correct diagnosis and appropriate therapy are important contributor to successful outcome.

  5. Circuit For Control Of Electromechanical Prosthetic Hand

    Science.gov (United States)

    Bozeman, Richard J., Jr.

    1995-01-01

    Proposed circuit for control of electromechanical prosthetic hand derives electrical control signals from shoulder movements. Updated, electronic version of prosthesis, that includes two hooklike fingers actuated via cables from shoulder harness. Circuit built around favored shoulder harness, provides more dexterous movement, without incurring complexity of computer-controlled "bionic" or hydraulically actuated devices. Additional harness and potentiometer connected to similar control circuit mounted on other shoulder. Used to control stepping motor rotating hand about prosthetic wrist to one of number of angles consistent with number of digital outputs. Finger-control signals developed by circuit connected to first shoulder harness transmitted to prosthetic hand via sliprings at prosthetic wrist joint.

  6. First described case of prosthetic joint infection with Clostridium disporicum.

    Science.gov (United States)

    McBride, Joseph A; Sterkel, Alana K; Rehrauer, William M; Smith, Jeannina A

    2017-12-01

    An orthopedic hardware infection with Clostridium disporicum is described. C. disporicum is a gram positive anaerobic bacillus which can contain two subterminal spores. C. disporicum had not previously been reported in musculoskeletal infections. Gram stains demonstrating gram positive bacilli with two subterminal spores should alert practitioners to the possibility of C. disporicum infection. Published by Elsevier Ltd.

  7. Stiffness and hysteresis properties of some prosthetic feet

    NARCIS (Netherlands)

    van Jaarsveld, H.W.L.; Grootenboer, H.J.; de Vries, J.; Koopman, Hubertus F.J.M.

    1990-01-01

    A prosthetic foot is an important element of a prosthesis, although it is not always fully recognized that the properties of the foot, along with the prosthetic knee joint and the socket, are in part responsible for the stability and metabolic energy cost during walking. The stiffness and the

  8. Antimicrobial photodynamic therapy-a promising treatment for prosthetic joint infections.

    Science.gov (United States)

    Briggs, Timothy; Blunn, Gordon; Hislop, Simon; Ramalhete, Rita; Bagley, Caroline; McKenna, David; Coathup, Melanie

    2018-04-01

    Periprosthetic joint infection (PJI) is associated with high patient morbidity and a large financial cost. This study investigated Photodynamic Therapy (PDT) as a means of eradicating bacteria that cause PJI, using a laser with a 665-nm wavelength and methylene blue (MB) as the photosensitizer. The effectiveness of MB concentration on the growth inhibition of methicillin-sensitive Staphylococcus aureus (MSSA), methicillin-resistant Staphylococcus aureus (MRSA), Staphylococcus epidermidis, Pseudomonas aeruginosa and Acinetobacter baumannii was investigated. The effect of laser dose was also investigated and the optimized PDT method was used to investigate its bactericidal effect on species within planktonic culture and following the formation of a biofilm on polished titanium and hydroxyapatite coated titanium discs. Results showed that Staphylococci were eradicated at the lowest concentration of 0.1 mM methylene blue (MB). With P. aeruginosa and A. baumannii, increasing the MB concentration improved the bactericidal effect. When the laser dose was increased, results showed that the higher the power of the laser the more bacteria were eradicated with a laser power ≥ 35 J/cm 2 and an irradiance of 35 mW/cm 2 , eradicating all S. epidermidis. The optimized PDT method had a significant bactericidal effect against planktonic MRSA and S. epidermidis compared to MB alone, laser alone, or control (no treatment). When biofilms were formed, PDT treatment had a significantly higher bactericidal effect than MB alone and laser alone for all species of bacteria investigated on the polished disc surfaces. P. aeruginosa grown in a biofilm was shown to be less sensitive to PDT when compared to Staphylococci, and a HA-coated surface reduced the effectiveness of PDT. This study demonstrated that PDT is effective for killing bacteria that cause PJI.

  9. Accuracy of FDG-PET-CT in the Diagnostic Work-up of Vascular Prosthetic Graft Infection

    NARCIS (Netherlands)

    Bruggink, J. L. M.; Glaudemans, A. W. J. M.; Saleem, B. R.; Meerwaldt, R.; Alkefaji, H.; Prins, T. R.; Start, R. H. J. A.; Zeebregts, C. J.

    Objectives: To investigate the diagnostic accuracy of fluoro-2-deoxy-D-glucose positron emission tomography (FDG-PET) compared with computed tomography (CT) scanning and added value of fused FDG-PET CT in diagnosing vascular prosthetic graft infection. Design: Prospective cohort study with

  10. Prosthetics / Limb Loss

    Science.gov (United States)

    ... implant to encourage the sealing process. Implanting titanium prosthetic components avoids the need for a socket. But preventing bacterial invasion and infection is a key challenge, one that this research ...

  11. Stiffness and hysteresis properties of some prosthetic feet

    OpenAIRE

    van Jaarsveld, H.W.L.; Grootenboer, H.J.; de Vries, J.; Koopman, Hubertus F.J.M.

    1990-01-01

    A prosthetic foot is an important element of a prosthesis, although it is not always fully recognized that the properties of the foot, along with the prosthetic knee joint and the socket, are in part responsible for the stability and metabolic energy cost during walking. The stiffness and the hysteresis, which are the topics of this paper, are not properly prescribed, but could be adapted to improve the prosthetic walking performance. The shape is strongly related to the cosmetic appearance a...

  12. The treatment and outcome of peri-prosthetic infection of the ankle: a single cohort-centre experience of 34 cases.

    Science.gov (United States)

    Kessler, B; Knupp, M; Graber, P; Zwicky, L; Hintermann, B; Zimmerli, W; Sendi, P

    2014-06-01

    The treatment of peri-prosthetic joint infection (PJI) of the ankle is not standardised. It is not clear whether an algorithm developed for hip and knee PJI can be used in the management of PJI of the ankle. We evaluated the outcome, at two or more years post-operatively, in 34 patients with PJI of the ankle, identified from a cohort of 511 patients who had undergone total ankle replacement. Their median age was 62.1 years (53.3 to 68.2), and 20 patients were women. Infection was exogenous in 28 (82.4%) and haematogenous in six (17.6%); 19 (55.9%) were acute infections and 15 (44.1%) chronic. Staphylococci were the cause of 24 infections (70.6%). Surgery with retention of one or both components was undertaken in 21 patients (61.8%), both components were replaced in ten (29.4%), and arthrodesis was undertaken in three (8.8%). An infection-free outcome with satisfactory function of the ankle was obtained in 23 patients (67.6%). The best rate of cure followed the exchange of both components (9/10, 90%). In the 21 patients in whom one or both components were retained, four had a relapse of the same infecting organism and three had an infection with another organism. Hence the rate of cure was 66.7% (14 of 21). In these 21 patients, we compared the treatment given to an algorithm developed for the treatment of PJI of the knee and hip. In 17 (80.9%) patients, treatment was not according to the algorithm. Most (11 of 17) had only one criterion against retention of one or both components. In all, ten of 11 patients with severe soft-tissue compromise as a single criterion had a relapse-free survival. We propose that the treatment concept for PJI of the ankle requires adaptation of the grading of quality of the soft tissues. ©2014 The British Editorial Society of Bone & Joint Surgery.

  13. Surgical and Antimicrobial Treatment of Prosthetic Vascular Graft Infections at Different Surgical Sites: A Retrospective Study of Treatment Outcomes

    Science.gov (United States)

    Elzi, Luigia; Gurke, Lorenz; Battegay, Manuel; Widmer, Andreas F.; Weisser, Maja

    2014-01-01

    Objective Little is known about optimal management of prosthetic vascular graft infections, which are a rare but serious complication associated with graft implants. The goal of this study was to compare and characterize these infections with respect to the location of the graft and to identify factors associated with outcome. Methods This was a retrospective study over more than a decade at a tertiary care university hospital that has an established multidisciplinary approach to treating graft infections. Cases of possible prosthetic vascular graft infection were identified from the hospital's infectious diseases database and evaluated against strict diagnostic criteria. Patients were divided into groups according to the locations of their grafts: thoracic-aortic, abdominal-aortic, or peripheral-arterial. Statistical analyses included evaluation of patient and infection characteristics, time to treatment failure, and factors associated specifically with cure rates in aortic graft infections. The primary endpoint was cure at one year after diagnosis of the infection. Results Characterization of graft infections according to the graft location did show that these infections differ in terms of their characteristics and that the prognosis for treatment seems to be influenced by the location of the infection. Cure rate and all-cause mortality at one year were 87.5% and 12.5% in 24 patients with thoracic-aortic graft infections, 37.0% and 55.6% in 27 patients with abdominal-aortic graft infections, and 70.0% and 30.0% in 10 patients with peripheral-arterial graft infections. In uni- and multivariate analysis, the type of surgical intervention used in managing infections (graft retention versus graft replacement) did not affect primary outcome, whereas a rifampicin-based antimicrobial regimen was associated with a higher cure rate. Conclusions We recommend that future prospective studies differentiate prosthetic vascular graft infections according to the location of the

  14. Detection of thoracic aortic prosthetic graft infection with 18F-fluorodeoxyglucose positron emission tomography/computed tomography.

    Science.gov (United States)

    Tokuda, Yoshiyuki; Oshima, Hideki; Araki, Yoshimori; Narita, Yuji; Mutsuga, Masato; Kato, Katsuhiko; Usui, Akihiko

    2013-06-01

    To investigate the diagnostic value of (18)F-fluorodeoxyglucose positron emission tomography/computed tomography (FDG-PET/CT) in detecting thoracic aortic prosthetic graft infection. Nine patients with clinically suspected thoracic aortic graft infection underwent FDG-PET/CT scanning. In these patients, the diagnoses could not be confirmed using conventional modalities. The patients' clinical courses were retrospectively reviewed. On the basis of surgical, microbiological and clinical follow-up findings, the aortic grafts were considered infected in 4 patients and not infected in 5. All 4 patients with graft infection (root: 2 cases, arch: 1 case and descending: 1 case) eventually underwent in situ re-replacement. Two of the 4 patients also had abdominal grafts; however, only the thoracic grafts were replaced because uptake was low around the abdominal grafts. The maximal standardized uptake value (SUVmax) in the perigraft area was higher in the infected group than in the non-infected group (11.4 ± 4.5 vs 6.9 ± 6.4), although the difference was not statistically significant. According to the receiver operating characteristic analysis, SUVmax >8 appeared to be the cut-off value in distinguishing the two groups (sensitivity: 1.0 and specificity: 0.8). FDG-PET/CT is useful for confirming the presence of graft infection by detecting high uptake around grafts and excluding other causes of inflammation. An SUVmax value greater than 8 around a graft suggests the presence of graft infection. In addition, FDG-PET/CT can be used to clarify the precise extent of infection. This is especially useful if multiple separated prosthetic grafts have been implanted.

  15. The efficacy of 99mTc-ciprofloxacin (infecton) imaging in suspected prosthetic infection following total knee replacement arthroplasty (pilot study)

    International Nuclear Information System (INIS)

    Kim, Jong Ho; Choi, Tae Hyun; Kim, Nam Bum

    2002-01-01

    The aims of this study were 1) to increase the labelling efficiency of 99m Tc-ciprofloxacin (infecton) and 2) to determine the value of infecton imaging in demonstrating infection following total knee replacement arthroplasty (TKRA). Five patients (4 female, 1 male: mean age 52.8±13.5 years, both TKRA in 3 pt) with suspected prosthetic infective conditions were included. In order to increase labelling efficiency, infection was labelled with stannous tartrate instead of previousely used formamidine sulfinic acid (FSA). Immediate perfusion, 5min blood pool, 1hr, 4hr and 24hr delayed images were perfomed. All images were blindly interpreted by two independent observers with visual findings being classified according to a four-grade scale(0.1.2.3). Images graded 0 and 1, and also those regions which showed faintly increase or unchanged uptake grade on late images as compared with early images, were classified as negative; grades 2 and 3 were classified as positive. The diagnosis was confirmed by intraoperative microbiological / histological findings or by the presence of gross purulence. Labelling efficiency increased up to over 98% with formation of radiocolloid less than 1%. All of four pt with prosthetic infection showed positive infecton images but one pt with sterile loosening of prosthesis showed negative infection images. The easy availability as well as new labelling technique make infecton imaging the better option for the detection of prosthetic orthopedic infection

  16. Outcome of Acute Prosthetic Joint Infections Due to Gram-Negative Bacilli Treated with Open Debridement and Retention of the Prosthesis▿

    Science.gov (United States)

    Martínez-Pastor, Juan C.; Muñoz-Mahamud, Ernesto; Vilchez, Félix; García-Ramiro, Sebastián; Bori, Guillem; Sierra, Josep; Martínez, José A.; Font, Lluis; Mensa, Josep; Soriano, Alex

    2009-01-01

    The aim of our study was to evaluate the outcome of acute prosthetic joint infections (PJIs) due to gram-negative bacilli (GNB) treated without implant removal. Patients with an acute PJI due to GNB diagnosed from 2000 to 2007 were prospectively registered. Demographics, comorbidity, type of implant, microbiology data, surgical treatment, antimicrobial therapy, and outcome were recorded. Classification and regression tree analysis, the Kaplan-Meier survival method, and the Cox regression model were applied. Forty-seven patients were included. The mean age was 70.7 years, and there were 15 hip prostheses and 32 knee prostheses. The median number of days from the time of arthroplasty was 20. The most frequent pathogens were members of the Enterobacteriaceae family in 41 cases and Pseudomonas spp. in 20 cases. Among the Enterobacteriaceae, 14 were resistant to ciprofloxacin, while all Pseudomonas aeruginosa isolates were susceptible to ciprofloxacin. The median durations of intravenous and oral antibiotic treatment were 14 and 64 days, respectively. A total of 35 (74.5%) patients were in remission after a median follow-up of 463 days (interquartile range, 344 to 704) days. By use of the Kaplan-Meier survival curve, a C-reactive protein (CRP) concentration of ≤15 mg/dl (P = 0.03) and receipt of a fluoroquinolone, when all GNB isolated were susceptible (P = 0.0009), were associated with a better outcome. By use of a Cox regression model, a CRP concentration of ≤15 mg/dl (odds ratio [OR], 3.57; 95% confidence interval [CI], 1.05 to 12.5; P = 0.043) and receipt of a fluoroquinolone (OR, 9.09; 95% CI, 1.96 to 50; P = 0.005) were independently associated with better outcomes. Open debridement without removal of the implant had a success rate of 74.5%, and the factors associated with good prognosis were a CRP concentration at the time of diagnosis ≤15 mg/dl and treatment with a fluoroquinolone. PMID:19687237

  17. The efficacy of {sup 99m}Tc-ciprofloxacin (infecton) imaging in suspected prosthetic infection following total knee replacement arthroplasty (pilot study)

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Jong Ho; Choi, Tae Hyun; Kim, Nam Bum [Gachon Medical School, Incheon (Korea, Republic of)

    2002-07-01

    The aims of this study were 1) to increase the labelling efficiency of {sup 99m}Tc-ciprofloxacin (infecton) and 2) to determine the value of infecton imaging in demonstrating infection following total knee replacement arthroplasty (TKRA). Five patients (4 female, 1 male: mean age 52.8{+-}13.5 years, both TKRA in 3 pt) with suspected prosthetic infective conditions were included. In order to increase labelling efficiency, infection was labelled with stannous tartrate instead of previousely used formamidine sulfinic acid (FSA). Immediate perfusion, 5min blood pool, 1hr, 4hr and 24hr delayed images were perfomed. All images were blindly interpreted by two independent observers with visual findings being classified according to a four-grade scale(0.1.2.3). Images graded 0 and 1, and also those regions which showed faintly increase or unchanged uptake grade on late images as compared with early images, were classified as negative; grades 2 and 3 were classified as positive. The diagnosis was confirmed by intraoperative microbiological / histological findings or by the presence of gross purulence. Labelling efficiency increased up to over 98% with formation of radiocolloid less than 1%. All of four pt with prosthetic infection showed positive infecton images but one pt with sterile loosening of prosthesis showed negative infection images. The easy availability as well as new labelling technique make infecton imaging the better option for the detection of prosthetic orthopedic infection.

  18. A new rabbit model of implant-related biofilm infection: development and evaluation

    Science.gov (United States)

    Chu, Cheng-Bing; Zeng, Hong; Shen, Ding-Xia; Wang, Hui; Wang, Ji-Fang; Cui, Fu-Zhai

    2016-03-01

    This study is to establish a rabbit model for human prosthetic joint infection and biofilm formation. Thirty-two healthy adult rabbits were randomly divided into four groups and implanted with stainless steel screws and ultra-high molecular weight polyethylene (UHMWPE) washers in the non-articular surface of the femoral lateral condyle of the right hind knees. The rabbit knee joints were inoculated with 1 mL saline containing 0, 102, 103, 104 CFU of Staphylococcus epidermidis ( S. epidermidis) isolated from the patient with total knee arthroplasty (TKA) infection, respectively. On the 14th postoperative day, the UHMWPE washers from the optimal 103 CFU group were further examined. The SEM examination showed a typical biofilm construction that circular S. epidermidis were embedded in a mucous-like matrix. In addition, the LCSM examination showed that the biofilm consisted of the polysaccharide stained bright green fluorescence and S. epidermidis radiating red fluorescence. Thus, we successfully create a rabbit model for prosthetic joint infection and biofilm formation, which should be valuable for biofilm studies.

  19. Late prosthetic graft infection after frozen elephant trunk presenting by haemoptysis and positive ¹⁸F-fluorodeoxyglucose-positron emission tomography/computed tomography.

    Science.gov (United States)

    Morjan, Mohammed; Ali, Khaldoun; Harringer, Wolfgang; El-Essawi, Aschraf

    2014-11-01

    In cardiothoracic surgery, prosthetic graft infection represents a diagnostic and therapeutic challenge. Although clinical assessment, imaging techniques and microbiological investigations are helpful, late graft infection can be difficult to identify using classical diagnostic tools. An aggressive surgical approach involving removal and replacement of all prosthetic materials is technically demanding but remains the best strategy to eradicate infection. Herein, we report a case of a late aortic graft infection, after frozen elephant trunk implantation with atypical presentation, diagnosed with (18)F-fluorodeoxyglucose-positron emission tomography and treated successfully through a radical surgical strategy. This case emphasizes the emerging diagnostic role of positron emission tomography and encourages the adoption of an aggressive surgical approach. © The Author 2014. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.

  20. Can We Achieve Intuitive Prosthetic Elbow Control Based on Healthy Upper Limb Motor Strategies?

    Directory of Open Access Journals (Sweden)

    Manelle Merad

    2018-02-01

    Full Text Available Most transhumeral amputees report that their prosthetic device lacks functionality, citing the control strategy as a major limitation. Indeed, they are required to control several degrees of freedom with muscle groups primarily used for elbow actuation. As a result, most of them choose to have a one-degree-of-freedom myoelectric hand for grasping objects, a myoelectric wrist for pronation/supination, and a body-powered elbow. Unlike healthy upper limb movements, the prosthetic elbow joint angle, adjusted prior to the motion, is not involved in the overall upper limb movements, causing the rest of the body to compensate for the lack of mobility of the prosthesis. A promising solution to improve upper limb prosthesis control exploits the residual limb mobility: like in healthy movements, shoulder and prosthetic elbow motions are coupled using inter-joint coordination models. The present study aims to test this approach. A transhumeral amputated individual used a prosthesis with a residual limb motion-driven elbow to point at targets. The prosthetic elbow motion was derived from IMU-based shoulder measurements and a generic model of inter-joint coordinations built from healthy individuals data. For comparison, the participant also performed the task while the prosthetic elbow was implemented with his own myoelectric control strategy. The results show that although the transhumeral amputated participant achieved the pointing task with a better precision when the elbow was myoelectrically-controlled, he had to develop large compensatory trunk movements. Automatic elbow control reduced trunk displacements, and enabled a more natural body behavior with synchronous shoulder and elbow motions. However, due to socket impairments, the residual limb amplitudes were not as large as those of healthy shoulder movements. Therefore, this work also investigates if a control strategy whereby prosthetic joints are automatized according to healthy individuals

  1. Prosthesis infections after orthopedic joint replacement

    DEFF Research Database (Denmark)

    Song, Zhijun; Borgwardt, Lotte; Høiby, Niels

    2013-01-01

    Prosthesis-related infection is a serious complication for patients after orthopedic joint replacement, which is currently difficult to treat with antibiotic therapy. Consequently, in most cases, removal of the infected prosthesis is the only solution to cure the infection. It is, therefore...

  2. Engineered biomaterial and biophysical stimulation as combinatorial strategies to address prosthetic infection by pathogenic bacteria.

    Science.gov (United States)

    Boda, Sunil Kumar; Basu, Bikramjit

    2017-10-01

    A plethora of antimicrobial strategies are being developed to address prosthetic infection. The currently available methods for implant infection treatment include the use of antibiotics and revision surgery. Among the bacterial strains, Staphylococcus species pose significant challenges particularly, with regard to hospital acquired infections. In order to combat such life threatening infectious diseases, researchers have developed implantable biomaterials incorporating nanoparticles, antimicrobial reinforcements, surface coatings, slippery/non-adhesive and contact killing surfaces. This review discusses a few of the biomaterial and biophysical antimicrobial strategies, which are in the developmental stage and actively being pursued by several research groups. The clinical efficacy of biophysical stimulation methods such as ultrasound, electric and magnetic field treatments against prosthetic infection depends critically on the stimulation protocol and parameters of the treatment modality. A common thread among the three biophysical stimulation methods is the mechanism of bactericidal action, which is centered on biophysical rupture of bacterial membranes, the generation of reactive oxygen species (ROS) and bacterial membrane depolarization evoked by the interference of essential ion-transport. Although the extent of antimicrobial effect, normally achieved through biophysical stimulation protocol is insufficient to warrant therapeutic application, a combination of antibiotic/ROS inducing agents and biophysical stimulation methods can elicit a clinically relevant reduction in viable bacterial numbers. In this review, we present a detailed account of both the biomaterial and biophysical approaches for achieving maximum bacterial inactivation. Summarizing, the biophysical stimulation methods in a combinatorial manner with material based strategies can be a more potent solution to control bacterial infections. © 2016 Wiley Periodicals, Inc. J Biomed Mater Res Part B

  3. Role of radionuclide imaging for diagnosis of device and prosthetic valve infections

    Institute of Scientific and Technical Information of China (English)

    Jean-Fran?ois Sarrazin; Fran?ois Philippon; Mika?l Trottier; Michel Tessier

    2016-01-01

    Cardiovascular implantable electronic device(CIED) infection and prosthetic valve endocarditis(PVE) remain a diagnostic challenge.Cardiac imaging plays an important role in the diagnosis and management of patients with CIED infection or PVE.Over the past few years,cardiac radionuclide imaging has gained a key role in the diagnosis of these patients,and in assessing the need for surgery,mainly in the most difficult cases.Both 18F-fluorodeoxyglucose positron emission tomography/computed tomography(18F-FDG PET/CT) and radiolabelled white blood cell single-photon emission computed tomography/computed tomography(WBC SPECT/CT) have been studied in these situations.In their 2015 guidelines for the management of infective endocarditis,the European Society of Cardiology incorporated cardiac nuclear imaging as part of their diagnostic algorithm for PVE,but not CIED infection since the data were judged insufficient at the moment.This article reviews the actual knowledge and recent studies on the use of 18F-FDG PET/CT and WBC SPECT/CT in the context of CIED infection and PVE,and describes the technical aspects of cardiac radionuclide imaging.It also discusses their accepted and potential indications for the diagnosis and management of CIED infection and PVE,the limitations of these tests,and potential areas of future research.

  4. Role of radionuclide imaging for diagnosis of device and prosthetic valve infections

    Science.gov (United States)

    Sarrazin, Jean-François; Philippon, François; Trottier, Mikaël; Tessier, Michel

    2016-01-01

    Cardiovascular implantable electronic device (CIED) infection and prosthetic valve endocarditis (PVE) remain a diagnostic challenge. Cardiac imaging plays an important role in the diagnosis and management of patients with CIED infection or PVE. Over the past few years, cardiac radionuclide imaging has gained a key role in the diagnosis of these patients, and in assessing the need for surgery, mainly in the most difficult cases. Both 18F-fluorodeoxyglucose positron emission tomography/computed tomography (18F-FDG PET/CT) and radiolabelled white blood cell single-photon emission computed tomography/computed tomography (WBC SPECT/CT) have been studied in these situations. In their 2015 guidelines for the management of infective endocarditis, the European Society of Cardiology incorporated cardiac nuclear imaging as part of their diagnostic algorithm for PVE, but not CIED infection since the data were judged insufficient at the moment. This article reviews the actual knowledge and recent studies on the use of 18F-FDG PET/CT and WBC SPECT/CT in the context of CIED infection and PVE, and describes the technical aspects of cardiac radionuclide imaging. It also discusses their accepted and potential indications for the diagnosis and management of CIED infection and PVE, the limitations of these tests, and potential areas of future research. PMID:27721936

  5. Do Prolonged Prophylactic Antibiotics Reduce the Incidence of Surgical-Site Infections in Immediate Prosthetic Breast Reconstruction?

    Science.gov (United States)

    Wang, Frederick; Chin, Robin; Piper, Merisa; Esserman, Laura; Sbitany, Hani

    2016-12-01

    Approximately 50,000 women in the United States undergo mastectomy and immediate prosthetic breast reconstruction annually, and most receive postoperative prophylactic antibiotics. The effect of these antibiotics on the risk of surgical-site infections remains unclear. The authors searched the Medline, Embase, and Cochrane Library databases for studies that compared less than 24 hours and greater than 24 hours of antibiotics following immediate prosthetic breast reconstruction. Primary outcomes were surgical-site infections and implant loss. Conservative random effects models were used to obtain pooled relative risk estimates. The authors identified 927 studies, but only four cohort studies and one randomized controlled trial met their inclusion criteria. Unadjusted incidences of surgical-site infections were 14 percent with more than 24 hours of antibiotics, 19 percent with less than 24 hours of antibiotics, and 16 percent overall. Unadjusted incidences of implant loss were 8 percent with more than 24 hours of antibiotics, 10 percent with less than 24 hours of antibiotics, and 9 percent overall. The pooled relative risk of implant loss was 1.17 (95 percent CI, 0.39 to 3.6) with less than 24 hours of antibiotics, which was not statistically significant. Prolonged antibiotic use did not have a statistically significant effect on reducing surgical-site infections or implant loss. There was significant heterogeneity between studies, and prolonged antibiotics may have increased the risk of implant loss in the randomized controlled trial. Definitive evidence may only be obtained with data from more prospective randomized controlled trials.

  6. First report of Sneathia sanguinegens together with Mycoplasma hominis in postpartum prosthetic valve infective endocarditis: a case report.

    Science.gov (United States)

    Kotaskova, Iva; Nemec, Petr; Vanerkova, Martina; Malisova, Barbora; Tejkalova, Renata; Orban, Marek; Zampachova, Vita; Freiberger, Tomas

    2017-08-14

    The presence of more than one bacterial agent is relatively rare in infective endocarditis, although more common in prosthetic cases. Molecular diagnosis from a removed heart tissue is considered a quick and effective way to diagnose fastidious or intracellular agents. Here we describe the case of postpartum polymicrobial prosthetic valve endocarditis in a young woman. Sneathia sanguinegens and Mycoplasma hominis were simultaneously detected from the heart valve sample using broad range 16S rRNA polymerase chain reaction (PCR) followed by sequencing while culture remained negative. Results were confirmed by independent PCR combined with denaturing gradient gel electrophoresis. Before the final agent identification, the highly non-compliant patient left from the hospital against medical advice on empirical intravenous treatment with aminopenicillins, clavulanate and gentamicin switched to oral amoxycillin and clavulanate. Four months after surgery, no signs of inflammation were present despite new regurgitation and valve leaflet flail was detected. However, after another 5 months the patient died from sepsis and recurrent infective endocarditis of unclarified etiology. Mycoplasma hominis is a rare causative agent of infective endocarditis. To the best of our knowledge, presented case is the first report of Sneathia sanguinegens detected in this condition. Molecular techniques were shown to be useful even in polymicrobial infective endocarditis samples.

  7. Brief report: biomarkers of aortic vascular prosthetic graft infection in a porcine model with Staphylococcus aureus

    DEFF Research Database (Denmark)

    Langerhuus, S. N.; Tønnesen, E. K.; Jensen, K. H.

    2010-01-01

    Aortic vascular prosthetic graft infection (AVPGI) with Staphylococcus aureus is a feared post-operative complication. This study was conducted to evaluate the clinical signs and potential biomarkers of infection in a porcine AVPGI model. The biomarkers evaluated were: C-reactive protein (CRP......), fibrinogen, white blood cells (WBC), major histocompatibility complex II (MHC II) density, lymphocyte CD4:CD8 ratio and tumour necrosis factor-alpha (TNF-α) in vitro responsiveness. Sixteen pigs were included in the study, and randomly assigned into four groups (n = 4): “SHAM” pigs had their infra...

  8. Brucella Melitensis Review of the Human Infection Case

    Directory of Open Access Journals (Sweden)

    Šukrija Zvizdić

    2006-02-01

    Full Text Available Brucella spp. prosthetic joint infections are infrequently reported in the literature, particularly in returning travellers, and optimal treatment is unknown.METHOD:We describe a prosthetic joint infection (PJI caused by Brucella melitensis in a traveller returning to the UK from Thailand, which we believe to be the first detailed report of brucellosis in a traveller returning from this area. The 23 patients with Brucella-related PJI reported in the literature are summarised, together with our case.RESULTS:The diagnosis of Brucella-related PJI is difficult to make; only 30% of blood cultures and 75% of joint aspiration cultures were positive in the reported cases. Culture of intraoperative samples provides the best diagnostic yield. In the absence of radiological evidence of joint loosening, combination antimicrobial therapy alone may be appropriate treatment in the first instance; this was successful in 6/7 [86%] of patients, though small numbers of patients and the likelihood of reporting bias warrant caution in drawing any firm conclusions about optimal treatment. Aerosolisation of synovial fluid during joint aspiration procedures and nosocomial infection has been described.CONCLUSIONS:Brucella-related PJI should be considered in the differential of travellers returning from endemic areas with PJI, including Thailand. Personal protective equipment including fit tested filtering face piece-3 (FFP3 mask or equivalent is recommended for personnel carrying out joint aspiration when brucellosis is suspected. Travellers can reduce the risk of brucellosis by avoiding unpasteurised dairy products and animal contact (particularly on farms and abattoirs in endemic areas and should be counselled regarding these risks as part of their pre-travel assessment.

  9. The effect of polyethylene creep on tibial insert locking screw loosening and back-out in prosthetic knee joints.

    Science.gov (United States)

    Sanders, Anthony P; Raeymaekers, Bart

    2014-10-01

    A prosthetic knee joint typically comprises a cobalt-chromium femoral component that articulates with a polyethylene tibial insert. A locking screw may be used to prevent micromotion and dislodgement of the tibial insert from the tibial tray. Screw loosening and back-out have been reported, but the mechanism that causes screw loosening is currently not well understood. In this paper, we experimentally evaluate the effect of polyethylene creep on the preload of the locking screw. We find that the preload decreases significantly as a result of polyethylene creep, which reduces the torque required to loosen the locking screw. The torque applied to the tibial insert due to internal/external rotation within the knee joint during gait could thus drive locking screw loosening and back-out. The results are very similar for different types of polyethylene. Copyright © 2014 Elsevier Ltd. All rights reserved.

  10. Mechanical design and performance specifications of anthropomorphic prosthetic hands: a review.

    Science.gov (United States)

    Belter, Joseph T; Segil, Jacob L; Dollar, Aaron M; Weir, Richard F

    2013-01-01

    In this article, we set forth a detailed analysis of the mechanical characteristics of anthropomorphic prosthetic hands. We report on an empirical study concerning the performance of several commercially available myoelectric prosthetic hands, including the Vincent, iLimb, iLimb Pulse, Bebionic, Bebionic v2, and Michelangelo hands. We investigated the finger design and kinematics, mechanical joint coupling, and actuation methods of these commercial prosthetic hands. The empirical findings are supplemented with a compilation of published data on both commercial and prototype research prosthetic hands. We discuss numerous mechanical design parameters by referencing examples in the literature. Crucial design trade-offs are highlighted, including number of actuators and hand complexity, hand weight, and grasp force. Finally, we offer a set of rules of thumb regarding the mechanical design of anthropomorphic prosthetic hands.

  11. Early prosthetic aortic valve infection identified with the use of positron emission tomography in a patient with lead endocarditis.

    Science.gov (United States)

    Amraoui, Sana; Tlili, Ghoufrane; Sohal, Manav; Bordenave, Laurence; Bordachar, Pierre

    2016-12-01

    18-Fluorodeoxyglucose positron emission tomography/computerized tomography (FDG PET/CT) scanning has recently been proposed as a diagnostic tool for lead endocarditis (LE). FDG PET/CT might be also useful to localize associated septic emboli in patients with LE. We report an interesting case of a LE patient with a prosthetic aortic valve in whom a trans-esophageal echocardiogram did not show associated aortic endocarditis. FDG PET/CT revealed prosthetic aortic valve infection. A second TEE performed 2 weeks after identified aortic vegetation. A longer duration of antimicrobial therapy with serial follow-up echocardiography was initiated. There was also increased uptake in the sigmoid colon, corresponding to focal polyps resected during a colonoscopy. FDG PET/CT scanning seems to be highly sensitive for prosthetic aortic valve endocarditis diagnosis. This promising diagnostic tool may be beneficial in LE patients, by identifying septic emboli and potential sites of pathogen entry.

  12. Modelling and Simulation of the Knee Joint with a Depth Sensor Camera for Prosthetics and Movement Rehabilitation

    Science.gov (United States)

    Risto, S.; Kallergi, M.

    2015-09-01

    The purpose of this project was to model and simulate the knee joint. A computer model of the knee joint was first created, which was controlled by Microsoft's Kinect for Windows. Kinect created a depth map of the knee and lower leg motion independent of lighting conditions through an infrared sensor. A combination of open source software such as Blender, Python, Kinect SDK and NI_Mate were implemented for the creation and control of the simulated knee based on movements of a live physical model. A physical size model of the knee and lower leg was also created, the movement of which was controlled remotely by the computer model and Kinect. The real time communication of the model and the robotic knee was achieved through programming in Python and Arduino language. The result of this study showed that Kinect in the modelling of human kinematics and can play a significant role in the development of prosthetics and other assistive technologies.

  13. Modelling and Simulation of the Knee Joint with a Depth Sensor Camera for Prosthetics and Movement Rehabilitation

    International Nuclear Information System (INIS)

    Risto, S; Kallergi, M

    2015-01-01

    The purpose of this project was to model and simulate the knee joint. A computer model of the knee joint was first created, which was controlled by Microsoft's Kinect for Windows. Kinect created a depth map of the knee and lower leg motion independent of lighting conditions through an infrared sensor. A combination of open source software such as Blender, Python, Kinect SDK and NI-Mate were implemented for the creation and control of the simulated knee based on movements of a live physical model. A physical size model of the knee and lower leg was also created, the movement of which was controlled remotely by the computer model and Kinect. The real time communication of the model and the robotic knee was achieved through programming in Python and Arduino language. The result of this study showed that Kinect in the modelling of human kinematics and can play a significant role in the development of prosthetics and other assistive technologies. (paper)

  14. TREATMENT OF DEEP PERIPROSTHETIC INFECTION OF KNEE JOINT

    Directory of Open Access Journals (Sweden)

    Ivantsov V. A.

    2018-03-01

    Full Text Available In connection with the increase in arthroplasty of joints, the problem of infectious complications becomes topical. The aim of the study was to increase the effectiveness of purulent complications treatment after total knee arthroplasty. Material and methods. Treatment of patients with deep periprosthetic infection of the knee joint dealt with surgical debridement with the preservation of endoprosthesis, its removal and placement of a cement spacer or with the removal of endoprosthesis and arthrodesis of the knee joint. Surgical debridement was related to the radical excision of necrotic tissues and the remains of the synovial membrane. To prepare the cement spacer bone cement "CEMFIX" or "GENTAFIX" impregnated with antibiotic was used. For arthrodesis of the knee joint, Medbiotech core apparatus (the Republic of Belarus superimposed on the limb in the frontal and sagittal planes was applied. Results. The use of a differentiated and individual approach to the treatment of deep periprosthetic infection of the knee joint enabled to obtain positive results in 85.6% of cases. Conclusions. The two-stage method of treatment of deep periprosthetic infection of the knee joint is preferred, as compared to a one-stage method, which enables to obtain better results.

  15. Capnocytophaga canimorsus - An underestimated cause of periprosthetic joint infection?

    Science.gov (United States)

    Orth, Marcel; Orth, Patrick; Anagnostakos, Konstantinos

    2017-08-01

    Periprosthetic joint infection (PJI) is a major clinical problem in orthopedic surgery. Capnocytophaga canimorsus (C. canimorsus) is an unusual and hardly detectable bacterium. A review of the literature indicates that C. canimorsus affects mainly immunocompromised patients. It has not been reported to cause periprosthetic joint infections in immunocompetent patients so far. This case report aims to raise awareness of C. canimorsus in orthopedic surgery with special regard to joint arthroplasty. We report a case of a 54-year-old immunocompetent patient with a late infection after total knee arthroplasty caused by C. canimorsus. The patient underwent two-stage revision with prosthesis explantation, implantation of an antibiotic-impregnated static spacer, intravenous antimicrobial therapy for four weeks with cefuroxime followed by oral antimicrobial therapy with ciprofloxacin for further two weeks and secondary revision total knee arthroplasty. In the present case, we could demonstrate that adequate treatment of C. canimorsus was capable to successfully treat periprosthetic joint infection caused by C. canimorsus in an immunocompetent patient. We feel that C. canimorsus has to be taken into account as a potential pathogen causing periprosthetic joint infection - regardless of the immunological status of the patient and especially when the detection of a pathogen does not succeed. Copyright © 2017 Elsevier B.V. All rights reserved.

  16. Differentiation between peri-prosthetic infection and aseptic loosening using quantitative analysis of triphasic 99Tcm-MDP bone scintigraphy

    International Nuclear Information System (INIS)

    Li Xinxin; Zhang Yanyan; Zhang Weifang; Mao Yuan; Zhao Meixin

    2013-01-01

    Objective: To differentiate between peri-prosthetic infection and aseptic loosening using quantitative analysis of triphasic bone scintigraphy. Methods: Twenty-eight patients (9 males, 19 females; mean age 67.5 years, range 49-80 years) with recurrent joint pain after arthroplasty were retrospectively assessed. All patients underwent triphasic bone scintigraphy. ROI of each joint was drawn and the ratios of affected to unaffected side were calculated. The ratios of blood flow phase, blood pool phase, static phase, C-reactive protein (CRP) and erythrocyte sedimentation (ESR) were quantitatively analyzed by ROC curve. The final diagnosis was based on microbiological and histological examinations. The optimal cut-off value was chosen based on the ideal sensitivity and specificity. Results: Nine patients were diagnosed as septic loosening, 17 patients aseptic loosening, 1 patient bursitis of hip joint and 1 patient suture reaction. Taking the positive results of blood flow phase or blood pool phase as standard for diagnosing septic loosening, the sensitivity, specificity and accuracy of bone scintigraphy were 7/9, 78.9% (15/19) and 78.6% (22/28), respectively. The AUC of blood pool phase was 0.942, and the sensitivity and specificity were 8/9 and 78.9% (15/19), respectively, with the optimal cut-off value of 1.40. The AUCs of blood flow ratio and CRP were 0.816 and 0.795, with cut-off values of 1.53 and 1.20, respectively. The AUCs of static phase ratio and ESR were 0.474 and 0.722, respectively, both P>0.05. Conclusions: For the diagnosis of septic loosening, quantitative analysis of triphasic 99 Tc m -MDP bone scintigraphy, particularly with the ratio of blood pool phase, is more accurate than qualitative analysis. (authors)

  17. Radionuclide imaging of musculoskeletal infection

    International Nuclear Information System (INIS)

    Palestr, Christopher J.; North Shore Long Island Jewish Health System, Manhasset and New Hyde Park, NY; Love, Charito

    2007-01-01

    Radionuclide imaging studies are routinely used to evaluate patients suspected of having musculoskeletal infection. Three-phase bone imaging is readily available, relatively inexpensive, and very accurate in the setting of otherwise normal bone. Labeled leukocyte imaging should be used in cases of 'complicating osteomyelitis' such as prosthetic joint infection. This test also is useful in clinically unsuspected diabetic pedal osteomyelitis as well as in the neuropathic joint. It is often necessary, however, to perform complementary bone marrow imaging, to maximize the accuracy of labeled leukocyte imaging. In contrast to other regions in the skeleton, labeled leukocyte imaging is not useful for diagnosing spinal osteomyelitis. At the moment, gallium is the preferred radionuclide procedure for this condition and is a useful adjunct to magnetic resonance imaging. FDG-PET likely will play an important role in the evaluation of musculoskeletal infection, especially spinal osteomyelitis, and may replace gallium imaging for this purpose. (author)

  18. Acute sacroiliac joint infection in a rugby player with atopic dermatitis.

    Science.gov (United States)

    Yasuda, Tadashi; Nisimatsu, Hidekazu

    2012-11-01

    In athletes, acute bacterial infection is an unusual cause of pain in the sacroiliac joint. Although an entry site for infection is not always evident, the present case of a 15-year-old rugby player suggests the association between right sacroiliac joint infection and skin lesion of atopic dermatitis (AD) infected with group A streptococcus. Magnetic resonance imaging revealed inflammation around the sacroiliac joint with abscess formation. The infection resolved after a course of antibiotics. Because atopic skin lesion is a potential portal of bacteria, treatment for AD is essential for the prevention of pyogenic arthritis in athletes.

  19. Multi-Axis Prosthetic Knee Resembles Alpine Skiing Movements of an Intact Leg

    Science.gov (United States)

    Demšar, Ivan; Duhovnik, Jože; Lešnik, Blaž; Supej, Matej

    2015-01-01

    The purpose of the study was to analyse the flexion angles of the ski boot, ankle and knee joints of an above-knee prosthesis and to compare them with an intact leg and a control group of skiers. One subject with an above-knee amputation of the right leg and eight healthy subjects simulated the movement of a skiing turn by performing two-leg squats in laboratory conditions. By adding additional loads in proportion to body weight (BW; +1/3 BW, +2/3 BW, +3/3 BW), various skiing regimes were simulated. Change of Flexion Angle (CoFA) and Range of Motion (RoM) in the ski boot, ankle and knee joints were calculated and compared. An average RoM in the skiing boot on the side of prosthesis (4.4 ± 1.1°) was significantly lower compared to an intact leg (5.9 ± 1.8°) and the control group (6.5 ± 2.3°). In the ankle joint, the average RoM was determined to be 13.2±2.9° in the prosthesis, 12.7 ± 2.8° in an intact leg and 14.8±3.6 in the control group. However, the RoM of the knee joint in the prosthesis (42.2 ± 4.2°) was significantly larger than that of the intact leg (34.7 ± 4.4°). The average RoM of the knee joint in the control group was 47.8 ± 5.4°. The influences of additional loads on the kinematics of the lower extremities were different on the side of the prosthesis and on the intact leg. In contrast, additional loads did not produce any significant differences in the control group. Although different CoFAs in the ski boot, ankle and knee joints were used, an above-knee prosthesis with a built-in multi-axis prosthetic knee enables comparable leg kinematics in simulated alpine skiing. Key points The RoM in the ski boot on the side of the prosthetic leg was smaller than the RoM of the intact leg and the control group of healthy subjects. The RoM in the ankle joint of prosthetic leg was comparable to that of the intact leg and the control group of healthy subjects. The RoM in the prosthetic knee joint was greater than the RoM in the knee joint of the

  20. A qualitative study of the challenges of providing pre-prosthetic rehabilitation in rural South Africa.

    Science.gov (United States)

    Ennion, Liezel; Johannesson, Anton

    2018-04-01

    There is a known shortage of rehabilitation staff in rural settings and a sharp increase in the number of lower limb amputations being performed. A lack of adequate pre-prosthetic rehabilitation will result in worse physical and psychological outcomes for a person with a lower limb amputation, and they will not be eligible to be fitted with a prosthesis. To explore therapists' experiences with providing pre-prosthetic rehabilitation in a rural setting. A qualitative descriptive approach was used to collect and analyse data. Data were collected from 17 purposively sampled therapists in five district hospitals in a rural community in South Africa. Data were collected in two rounds of focus groups to explore the challenges of providing pre-prosthetic rehabilitation in rural South Africa. The main themes identified in the study were (1) a lack of government health system support, (2) poor socioeconomic circumstances of patients and (3) cultural factors that influence rehabilitation. These themes all negatively influence the therapists' ability to follow up patients for pre-prosthetic rehabilitation after discharge from hospital. A lack of adequate pre-prosthetic rehabilitation is a substantial barrier to prosthetic fitting in rural South Africa. Patients who do not receive pre-prosthetic rehabilitation have a poorly shaped residuum or other complications such as knee or hip joint contractures which disqualifies them from being referred to prosthetic services. Therapists involved in this study identified the most important barriers to patients having access to prosthetic services. Clinical relevance Pre-prosthetic rehabilitation provides care of the residuum; maintenance or improvement of physical strength, joint range of motion and referral to a prosthetist. By exploring the challenges known to exist in this service, we can identify potential ways to reduce these barriers and improve the lives of those who use it.

  1. Imaging of hip joint arthroplasty

    International Nuclear Information System (INIS)

    Mayerhoefer, M.E.; Fruehwald-Pallamar, J.; Czerny, C.

    2009-01-01

    The hip joint is the largest joint in the human body and consequently, its evaluation by diagnostic imaging is highly important. This includes imaging of hip joint arthroplasty, which is used to avoid joint immobility following a wide spectrum of diseases, such as end-stage degenerative disease, avascular necrosis of the femoral head or post-traumatic fractures. Conventional radiography is still the standard imaging modality for the evaluation of hip arthroplasty both directly following surgery and for periodical follow-up. In the majority of cases conventional radiography enables adequate assessment of early and late complications that can arise following hip arthroplasty, such as loosening, prosthetic or periprosthetic fracture, luxation, infection and soft tissue calcification. If the diagnosis cannot be established by means of radiography, advanced imaging methods such as computed tomography (CT) and magnetic resonance imaging (MRI), with or without injection of contrast media, may provide additional information. This is particularly true for the depiction of inflammatory processes. Regardless of the imaging modality used patients' clinical symptoms must also be taken into account in order to establish the correct diagnosis. (orig.) [de

  2. Echocardiographic evaluation of heart valve prosthetic dysfunction

    Directory of Open Access Journals (Sweden)

    Yuriy Ivaniv

    2018-02-01

    Full Text Available Patients with replaced heart valve submitted to echocardiographic examination may have symptoms related either to valvular malfunction or ventricular dysfunction from different causes. Clinical examination is not reliable in a prosthetic valve evaluation and the main information regarding its function could be obtained using different cardiac ultrasound modalities. This review provides a description of echocardiographic and Doppler techniques useful in evaluation of prosthetic heart valves. For the interpretation of echocardiography there is a need in special knowledge of prosthesis types and possible reasons of prosthetic function deterioration. Echocardiography allows to reveal valve thrombosis, pannus formation, vegetation and such complications of infective endocarditis as valve ring abscess or dehiscence. Transthoracic echocardiography requires different section plane angles and unconventional views. Transesophageal echocardiography is more often used than in native valve examination due to better visualization of prosthetic valve structure and function. Three-dimensional echocardiography could provide more detailed visual information especially in the assessment of paravalvular regurgitation or valve obstruction.

  3. Radionuclide imaging of the painful joint replacement: past, present and future

    Energy Technology Data Exchange (ETDEWEB)

    Palestro, Christopher J. [Long Island Jewish Medical Center, New Hyde Park, NY (United States)]. E-mail: palestro@lij.edu

    2002-09-01

    Differentiating aseptic loosening from infection as the cause of prosthetic joint failure is difficult because both entities are similar, clinically and histopathologically. Aseptic loosening frequently result from an immune reaction to the prosthesis. There is inflammation with an influx of histiocytes, giant cells, lymphocytes and plasma cells. Pro inflammatory cytokines and proteolytic enzymes are secreted, causing osteolysis and loosening. These same events occur in infection except that neutrophils, rarely present in aseptic loosening, area invariably present in infection. Clinical signs and symptoms, laboratory tests, X-rays and joint aspiration are insensitive, nonspecific or both. Artifacts produced by the metallic hardware hamper cross-sectional imaging modalities. Radionuclide imaging is not affected by the presence of metallic hardware and is very useful for evaluating the painful prosthesis. Bone scintigraphy, with and accuracy of 50%-70% is a useful screening test, since a normal study effectively excludes a prosthetic complication. Adding gallium-67, a nonspecific inflammation-imaging agent, improves the accuracy of bone scintigraphy to 70%-80%. The accuracy of combined leukocyte/marrow imaging, 90%, is the highest among available radionuclide studies. Its success is due to the fact that leukocytes imaging is most sensitive for detecting neutrophil mediated inflammations. Inflammatory conditions that are neutrophil-poor, even though large numbers of other leukocytes may be present, (such as the aseptically loosened joint prosthesis) go undetected. The success of leukocyte/marrow imaging is tempered by the limitations of in vitro labeling. In vivo labeling has been investigated and a murine monoclonal anti-granulocyte antibody appears promising. Some investigations have focused on F-18 FDG imaging, although specificity is a concern with this agent. (author)

  4. Radionuclide imaging of the painful joint replacement: past, present and future

    International Nuclear Information System (INIS)

    Palestro, Christopher J.

    2002-01-01

    Differentiating aseptic loosening from infection as the cause of prosthetic joint failure is difficult because both entities are similar, clinically and histopathologically. Aseptic loosening frequently result from an immune reaction to the prosthesis. There is inflammation with an influx of histiocytes, giant cells, lymphocytes and plasma cells. Pro inflammatory cytokines and proteolytic enzymes are secreted, causing osteolysis and loosening. These same events occur in infection except that neutrophils, rarely present in aseptic loosening, area invariably present in infection. Clinical signs and symptoms, laboratory tests, X-rays and joint aspiration are insensitive, nonspecific or both. Artifacts produced by the metallic hardware hamper cross-sectional imaging modalities. Radionuclide imaging is not affected by the presence of metallic hardware and is very useful for evaluating the painful prosthesis. Bone scintigraphy, with and accuracy of 50%-70% is a useful screening test, since a normal study effectively excludes a prosthetic complication. Adding gallium-67, a nonspecific inflammation-imaging agent, improves the accuracy of bone scintigraphy to 70%-80%. The accuracy of combined leukocyte/marrow imaging, 90%, is the highest among available radionuclide studies. Its success is due to the fact that leukocytes imaging is most sensitive for detecting neutrophil mediated inflammations. Inflammatory conditions that are neutrophil-poor, even though large numbers of other leukocytes may be present, (such as the aseptically loosened joint prosthesis) go undetected. The success of leukocyte/marrow imaging is tempered by the limitations of in vitro labeling. In vivo labeling has been investigated and a murine monoclonal anti-granulocyte antibody appears promising. Some investigations have focused on F-18 FDG imaging, although specificity is a concern with this agent. (author)

  5. One-stage exchange with antibacterial hydrogel coated implants provides similar results to two-stage revision, without the coating, for the treatment of peri-prosthetic infection.

    Science.gov (United States)

    Capuano, Nicola; Logoluso, Nicola; Gallazzi, Enrico; Drago, Lorenzo; Romanò, Carlo Luca

    2018-03-16

    Aim of this study was to verify the hypothesis that a one-stage exchange procedure, performed with an antibiotic-loaded, fast-resorbable hydrogel coating, provides similar infection recurrence rate than a two-stage procedure without the coating, in patients affected by peri-prosthetic joint infection (PJI). In this two-center case-control, study, 22 patients, treated with a one-stage procedure, using implants coated with an antibiotic-loaded hydrogel [defensive antibacterial coating (DAC)], were compared with 22 retrospective matched controls, treated with a two-stage revision procedure, without the coating. At a mean follow-up of 29.3 ± 5.0 months, two patients (9.1%) in the DAC group showed an infection recurrence, compared to three patients (13.6%) in the two-stage group. Clinical scores were similar between groups, while average hospital stay and antibiotic treatment duration were significantly reduced after one-stage, compared to two-stage (18.9 ± 2.9 versus 35.8 ± 3.4 and 23.5 ± 3.3 versus 53.7 ± 5.6 days, respectively). Although in a relatively limited series of patients, our data shows similar infection recurrence rate after one-stage exchange with DAC-coated implants, compared to two-stage revision without coating, with reduced overall hospitalization time and antibiotic treatment duration. These findings warrant further studies in the possible applications of antibacterial coating technologies to treat implant-related infections. III.

  6. New developments in prosthetic arm systems

    Directory of Open Access Journals (Sweden)

    Vujaklija I

    2016-07-01

    Full Text Available Ivan Vujaklija,1 Dario Farina,1 Oskar C Aszmann2 1Institute of Neurorehabilitation Systems, Bernstein Focus Neurotechnology Göttingen, University Medical Center Göttingen, Georg-August University, Göttingen, Germany; 2Christian Doppler Laboratory for Restoration of Extremity Function, Division of Plastic and Reconstructive Surgery, Department of Surgery, Medical University of Vienna, Vienna, Austria Abstract: Absence of an upper limb leads to severe impairments in everyday life, which can further influence the social and mental state. For these reasons, early developments in cosmetic and body-driven prostheses date some centuries ago, and they have been evolving ever since. Following the end of the Second World War, rapid developments in technology resulted in powered myoelectric hand prosthetics. In the years to come, these devices were common on the market, though they still suffered high user abandonment rates. The reasons for rejection were trifold – insufficient functionality of the hardware, fragile design, and cumbersome control. In the last decade, both academia and industry have reached major improvements concerning technical features of upper limb prosthetics and methods for their interfacing and control. Advanced robotic hands are offered by several vendors and research groups, with a variety of active and passive wrist options that can be articulated across several degrees of freedom. Nowadays, elbow joint designs include active solutions with different weight and power options. Control features are getting progressively more sophisticated, offering options for multiple sensor integration and multi-joint articulation. Latest developments in socket designs are capable of facilitating implantable and multiple surface electromyography sensors in both traditional and osseointegration-based systems. Novel surgical techniques in combination with modern, sophisticated hardware are enabling restoration of dexterous upper limb

  7. Radionuclide imaging of musculoskeletal infection

    Energy Technology Data Exchange (ETDEWEB)

    Palestr, Christopher J. [Albert Einstein College of Medicine, Bronx, NY (United States); North Shore Long Island Jewish Health System, Manhasset and New Hyde Park, NY (United States). Div. of Nuclear Medicine and Molecular Imaging; E-mail: palestro@lij.edu; Love, Charito [North Shore Long Island Jewish Health System, Manhasset and New Hyde Park, NY (United States). Div. of Nuclear Medicine and Molecular Imaging

    2007-09-15

    Radionuclide imaging studies are routinely used to evaluate patients suspected of having musculoskeletal infection. Three-phase bone imaging is readily available, relatively inexpensive, and very accurate in the setting of otherwise normal bone. Labeled leukocyte imaging should be used in cases of 'complicating osteomyelitis' such as prosthetic joint infection. This test also is useful in clinically unsuspected diabetic pedal osteomyelitis as well as in the neuropathic joint. It is often necessary, however, to perform complementary bone marrow imaging, to maximize the accuracy of labeled leukocyte imaging. In contrast to other regions in the skeleton, labeled leukocyte imaging is not useful for diagnosing spinal osteomyelitis. At the moment, gallium is the preferred radionuclide procedure for this condition and is a useful adjunct to magnetic resonance imaging. FDG-PET likely will play an important role in the evaluation of musculoskeletal infection, especially spinal osteomyelitis, and may replace gallium imaging for this purpose. (author)

  8. Prosthetic valve endocarditis caused by Staphylococcus capitis: report of 4 cases

    Directory of Open Access Journals (Sweden)

    Wada Yuko

    2011-10-01

    Full Text Available Abstract Although Staphylococcus capitis is considered to be a rare causative organism for prosthetic valve endocarditis, we report 4 such cases that were encountered at our hospital over the past 2 years. Case 1 was a 79-year-old woman who underwent aortic valve replacement with a bioprosthetic valve and presented with fever 24 days later. Transesophageal echocardiography revealed an annular abscess in the aorto-mitral continuity and mild perivalvular regurgitation. We performed emergency surgery 5 days after the diagnosis of prosthetic valve endocarditis was made. Case 2 was a 79-year-old woman presenting with fever 40 days after aortic valve replacement with a bioprosthesis. Transesophageal echocardiography showed vegetation on the valve, and she underwent urgent surgery 2 days after prosthetic valve endocarditis was diagnosed. In case 3, a 76-year-old man presented with fever 53 days after aortic valve replacement with a bioprosthesis. Vegetation on the prosthetic leaflet could be seen by transesophageal echocardiography. He underwent emergency surgery 2 days after the diagnosis of prosthetic valve endocarditis was made. Case 4 was a 68-year-old woman who collapsed at her home 106 days after aortic and mitral valve replacement with bioprosthetic valves. Percutaneous cardiopulmonary support was started immediately after massive mitral regurgitation due to prosthetic valve detachment was revealed by transesophageal echocardiography. She was transferred to our hospital by helicopter and received surgery immediately on arrival. In all cases, we re-implanted another bioprosthesis after removal of the infected valve and annular debridement. All patients recovered without severe complications after 2 months of antibiotic treatment, and none experienced re-infection during 163 to 630 days of observation. Since the time interval between diagnosis of prosthetic valve endocarditis and valve re-replacement ranged from 0 to 5 days, early surgical removal

  9. Welding of Prosthetic Alloys / Spawanie Stopów Protetycznych Typu Co-Cr

    Directory of Open Access Journals (Sweden)

    Wojciechowska M.

    2015-12-01

    Full Text Available This paper presents the techniques of joining metal denture elements, used in prosthetic dentistry: the traditional soldering technique with a gas burner and a new technique of welding with a laser beam; the aim of the study was to make a comparative assessment of the quality of the joints in view of the possibility of applying them in prosthetic structures. Fractographic examinations were conducted along with tensile strength and impact strength tests, and the quality of the joints was assessed compared to the solid metal. The experiments have shown that the metal elements used to make dentures, joined by the technique which employs a laser beam, have better strength properties than those achieved with a gas burner.

  10. Evaluation of a Musculoskeletal Model with Prosthetic Knee through Six Experimental Gait Trials

    OpenAIRE

    Kia, Mohammad; Stylianou, Antonis P.; Guess, Trent M.

    2014-01-01

    Knowledge of the forces acting on musculoskeletal joint tissues during movement benefits tissue engineering, artificial joint replacement, and our understanding of ligament and cartilage injury. Computational models can be used to predict these internal forces, but musculoskeletal models that simultaneously calculate muscle force and the resulting loading on joint structures are rare. This study used publicly available gait, skeletal geometry, and instrumented prosthetic knee loading data [1]...

  11. Do hip prosthesis related infection codes in administrative discharge registers correctly classify periprosthetic hip joint infection?

    DEFF Research Database (Denmark)

    Lange, Jeppe; Pedersen, Alma B; Troelsen, Anders

    2015-01-01

    PURPOSE: Administrative discharge registers could be a valuable and easily accessible single-sources for research data on periprosthetic hip joint infection. The aim of this study was to estimate the positive predictive value of the International Classification of Disease 10th revision (ICD-10...... in future single-source register based studies, but preferably should be used in combination with alternate data sources to ensure higher validity....... decreased to 82% (95% CI: 72-89). CONCLUSIONS: Misclassification must be expected and taken into consideration when using administrative discharge registers for epidemiological research on periprosthetic hip joint infection. We believe that the periprosthetic hip joint infection diagnosis code can be of use...

  12. Stair ascent with an innovative microprocessor-controlled exoprosthetic knee joint.

    Science.gov (United States)

    Bellmann, Malte; Schmalz, Thomas; Ludwigs, Eva; Blumentritt, Siegmar

    2012-12-01

    Climbing stairs can pose a major challenge for above-knee amputees as a result of compromised motor performance and limitations to prosthetic design. A new, innovative microprocessor-controlled prosthetic knee joint, the Genium, incorporates a function that allows an above-knee amputee to climb stairs step over step. To execute this function, a number of different sensors and complex switching algorithms were integrated into the prosthetic knee joint. The function is intuitive for the user. A biomechanical study was conducted to assess objective gait measurements and calculate joint kinematics and kinetics as subjects ascended stairs. Results demonstrated that climbing stairs step over step is more biomechanically efficient for an amputee using the Genium prosthetic knee than the previously possible conventional method where the extended prosthesis is trailed as the amputee executes one or two steps at a time. There is a natural amount of stress on the residual musculoskeletal system, and it has been shown that the healthy contralateral side supports the movements of the amputated side. The mechanical power that the healthy contralateral knee joint needs to generate during the extension phase is also reduced. Similarly, there is near normal loading of the hip joint on the amputated side.

  13. Impact of Early Valve Surgery on Outcome of Staphylococcus aureus Prosthetic Valve Infective Endocarditis: Analysis in the International Collaboration of Endocarditis–Prospective Cohort Study

    OpenAIRE

    Chirouze, Catherine; Alla, François; Fowler, Vance G.; Sexton, Daniel J.; Corey, G. Ralph; Chu, Vivian H.; Wang, Andrew; Erpelding, Marie-Line; Durante-Mangoni, Emanuele; Fernández-Hidalgo, Nuria; Giannitsioti, Efthymia; Hannan, Margaret M.; Lejko-Zupanc, Tatjana; Miró, José M.; Muñoz, Patricia

    2014-01-01

    Using appropriate analytical methods to examine data from the International Collaboration on Endocarditis–Prospective Cohort Study, we found that early valve surgery was not associated with reduced 1-year mortality in Staphylococcus aureus prosthetic valve infective endocarditis.

  14. 18F-Fluorodeoxyglucose Positron Emission Tomography/CT Scanning in Diagnosing Vascular Prosthetic Graft Infection

    Science.gov (United States)

    Saleem, Ben R.; Pol, Robert A.; Slart, Riemer H. J. A.; Reijnen, Michel M. P. J.; Zeebregts, Clark J.

    2014-01-01

    Vascular prosthetic graft infection (VPGI) is a severe complication after vascular surgery. CT-scan is considered the diagnostic tool of choice in advanced VPGI. The incidence of a false-negative result using CT is relatively high, especially in the presence of low-grade infections. 18F-fluorodeoxyglucose positron emission tomography (18F-FDG PET) scanning has been suggested as an alternative for the diagnosis and assessment of infectious processes. Hybrid 18F-FDG PET/CT has established the role of 18F-FDG PET for the assessment of suspected VPGI, providing accurate anatomic localization of the site of infection. However, there are no clear guidelines for the interpretation of the uptake patterns of 18F-FDG as clinical tool for VPGI. Based on the available literature it is suggested that a linear, diffuse, and homogeneous uptake should not be regarded as an infection whereas focal or heterogeneous uptake with a projection over the vessel on CT is highly suggestive of infection. Nevertheless, 18F-FDG PET and 18F-FDG PET/CT can play an important role in the detection of VPGI and monitoring response to treatment. However an accurate uptake and pattern recognition is warranted and cut-off uptake values and patterns need to be standardized before considering the technique to be the new standard. PMID:25210712

  15. In vitro adherence of bacteria to prosthetic grafting materials

    International Nuclear Information System (INIS)

    Brewer, A.R.; Stromberg, B.V.

    1990-01-01

    Adherence of bacteria to prosthetic grafting material is thought to play an important role in the ultimate development of prosthetic infections. To evaluate the role of bacterial adherence in the initiation and colonization of prosthetic materials, Proplast II, Gore-Tex, and silicone were evaluated for adherence of Escherichia coli and Staphylococcus aureus. Bacteria were radiolabeled and incubated with the study material. Adherence was determined by scintillation. Adherence to Proplast II and Gore-Tex reached a maximum at approximately 45 minutes of incubation and demonstrated a detachment phenomenon with E. coli. Similar results were noted with S. aureus, but with a maximal attachment at approximately 30 minutes. Interestingly, bacterial attachment to silicone continued to increase throughout the time of the incubation. In addition, adherence of S. aureus was at a faster rate than E. coli. Attachment of bacteria is a multifactorial process. However, the PTFE graft demonstrates a slower rate of attachment, lower total number of attached bacteria, and faster detachment. The importance of this phenomenon may help explain the foreign body effect of increased susceptibility to infection of foreign materials

  16. Preceding trauma in childhood hematogenous bone and joint infections.

    Science.gov (United States)

    Pääkkönen, Markus; Kallio, Markku J T; Lankinen, Petteri; Peltola, Heikki; Kallio, Pentti E

    2014-03-01

    Preceding trauma may play a role in the etiology and pathogenesis of hematogenous bone and joint infections. Among 345 children with an acute hematogenous bone and/or joint infection, 20% reported trauma during a 2-week period leading to infection. Blunt impact, bruises, or excoriations were commonly reported. The rate was similar to that in the general pediatric population obtained from the literature. In the study group, patients with and without trauma were similar in age, serum C-reactive protein and erythrocyte sedimentation rate, length of hospitalization, and late sequelae. Preceding minor trauma did not prove to be significant as an etiological or as a prognostic factor.

  17. In-111-labeled leukocyte scintigraphy in postoperative joint infection

    International Nuclear Information System (INIS)

    Ogawa, Yoji; Uetani, Masataka; Aziz, A.; Hayashi, Kuniaki

    2000-01-01

    To evaluate the role of In-111-labeled leukocyte scintigraphy in the patients with suspected postoperative joint infection, 41 scintigraphic examinations were performed in 24 patients. Scintigrams were interpreted by the degree of accumulation of labeled leukocytes, and were classified into 3 groups: positive, intermediate, and negative. In the cases of positive leukocyte scans, definite diagnosis of infection was made in all cases except one. In the cases of negative scans, there was no evidence of infection. In 13 cases, leukocyte scintigrams were interpreted in conjunction with bone scintigrams. Definite diagnosis of infection was made in all of the cases with positive combined leukocyte/bone scan, and there was no evidence of infection in cases with negative combined leukocyte/bone scan. This study demonstrates that In-111-labeled leukocyte scintigraphy is a useful method in diagnosis of postoperative joint infection, and accuracy of the examination improves when combined with bone scintigraphy. (author)

  18. [Treatment of bacterial infection in the interphalangeal joints of the hand].

    Science.gov (United States)

    Vorderwinkler, K-P; Mühldorfer, M; Pillukat, T; van Schoonhoven, J

    2011-07-01

    Radical debridement of joint infection, prevention of further infection-related tissue destruction. Septic arthritis of interphalangeal joints in the thumb and fingers. Extensive soft tissue defects. Severe impairment of blood circulation, finger gangrene. Noncompliance for immobilization or for treatment with external fixator. Arthrotomy and irrigation with isotonic solution. Radical tissue debridement. Joint preservation possible only in the absence of infection-related macroscopic cartilage damage. Otherwise, resection of the articular surfaces and secondary arthrodesis. Insertion of antibiotic-coated devices. Temporary immobilization with external fixator. Inpatient postoperative treatment with 5-day intravenous administration of a second-generation cephalosporine (e.g., Cefuroxim®) followed by 7-10 days oral application. Adaptation of antibiotics according to antibiogram results. In joint-preserving procedures, radiographs and fixator removal after 4 weeks, active joint mobilization. If joint surfaces were resected, removal of fixator after 6 weeks; arthrodesis under 3-day intravenous broad-band antibiotic prophylaxis. Splint immobilization until consolidation (6-8 weeks). In 10 of 40 patients, the infected joint could be preserved. All infections healed. After an average duration of therapy of 6 (3-11) weeks, 4 individuals were free of complaints, and 6 patients had minor symptoms. Overall range of motion in the affected finger was reduced by 25-50° in 5 patients. All patients could return to work after 6.6 (4-11) weeks. A total of 30 patients were treated with joint resection and external fixator. After 5.6 (4-8) weeks, arthrodesis was performed, leading to consolidation in 29 patients. One patient underwent amputation after 4 months due to delayed gangrene. Treatment duration was 15.7 (7-25) weeks. Eight patients reported no complaints, 14 suffered mild symptoms, 5 had moderate, and 3 had severe symptoms in daily life. In 15 cases, range

  19. Salmonella typhimurium infection in total knee arthroplasty: A case report with review of literature

    Directory of Open Access Journals (Sweden)

    Sujeesh Sebastian

    2017-01-01

    Full Text Available Salmonella enterica serotype Typhimurium is a rare cause of prosthetic joint infection (PJI. The recognized predisposing risk factors for Salmonella septic arthritis include diabetes mellitus, renal failure, human immunodeficiency virus infection and chronic corticosteroid use. We describe a case of PJI of the knee in a 74-year-old lady who was on antitubercular treatment. The patient presented with discharging sinus and raised inflammatory markers. She was successfully treated by the removal of prosthesis and debridement followed by ciprofloxacin therapy for 6 weeks. This case report highlights the potential virulence of Salmonella in immunocompromised patient with a joint prosthesis. Continuous monitoring and close collaboration of microbiologists and orthopedicians helped obtain the resolution of infection in our patient.

  20. 18F-FDG-PET/CT angiography in the diagnosis of infective endocarditis and cardiac device infection in adult patients with congenital heart disease and prosthetic material.

    Science.gov (United States)

    Pizzi, María N; Dos-Subirà, L; Roque, Albert; Fernández-Hidalgo, Nuria; Cuéllar-Calabria, Hug; Pijuan Domènech, Antonia; Gonzàlez-Alujas, María T; Subirana-Domènech, M T; Miranda-Barrio, B; Ferreira-González, Ignacio; González-López, Juan J; Igual, Albert; Maisterra-Santos, Olga; García-Dorado, David; Castell-Conesa, Joan; Almirante, Benito; Escobar Amores, Manuel; Tornos, Pilar; Aguadé-Bruix, Santiago

    2017-12-01

    Infective endocarditis (IE) and cardiac device infection (CDI) are a major complication in the growing number of patients with congenital heart disease (CHD) reaching adulthood. We aimed to evaluate the added value of 18 F-FDG-PET/CT angiography (PET/CTA) in the diagnosis of IE-CDI in adults with CHD and intravascular or intracardiac prosthetic material, in whom echocardiography (ECHO) and modified Duke Criteria (DC) have limitations because of the patients' complex anatomy. A prospective study was conducted in a referral center with multidisciplinary IE and CHD Units. PET/CTA and ECHO findings were compared in consecutive adult (≥18years) patients with CHD who have prosthetic material and suspected IE-CDI. The initial diagnosis using the DC and the diagnosis with the additional PET/CTA data (DC+PET/CTA) were compared with the final diagnostic consensus established by an expert team at three months. Between November-2012 and April-2017, 25 patients (15 men; median age 40years) were included. Cases were initially classified as definite in 8 (32%), possible in 14 (56%) and rejected in 3 (12%). DC+PET/CTA allowed reclassification of 12/14 (86%) cases initially identified as possible IE. The sensitivity, specificity, PPV, NPV, and accuracy of DC at IE suspicion were 39.1%/83.3%/90.4%/25.5%/61.2%, respectively. The diagnostic performance increased significantly with addition of PET/CTA data: 87%/83.3%/95.4%/61.5%/85.1%, respectively. PET/CTA also provided an alternative diagnosis in 3 patients with rejected IE, and detected pulmonary embolisms in 3 patients. PET/CTA was a useful diagnostic tool in the complex group of adult patients with CHD who have cardiac or intravascular prosthetic material and suspected IE or CDI, providing added diagnostic value to the modified DC (increased sensitivity) and improving case classification. Copyright © 2017 Elsevier Ireland Ltd. All rights reserved.

  1. Prosthetic design directives: Low-cost hands within reach.

    Science.gov (United States)

    Jones, G K; Rosendo, A; Stopforth, R

    2017-07-01

    Although three million people around the world suffer from the lack of one or both upper limbs 80% of this number is located within developing countries. While prosthetic prices soar with technology 3D printing and low cost electronics present a sensible solution for those that cannot afford expensive prosthetics. The electronic and control design of a low-cost prosthetic hand, the Touch Hand II, is discussed. This paper shows that sensorless techniques can be used to reduce design complexities, costs, and provide easier access to the electronics. A closing and opening finite state machine (COFSM) was developed to handle the actuated digit joint control state and a supervisory switching control scheme, used for speed and grip strength control. Three torque and speed settings were created to be preset for specific grasps. The hand was able to replicate ten frequently used grasps and grip some common objects. Future work is necessary to enable a user to control it with myoelectric signals (MESs) and to solve operational problems related to electromagnetic interference (EMI).

  2. Synovial fluid multiplex PCR is superior to culture for detection of low-virulent pathogens causing periprosthetic joint infection.

    Science.gov (United States)

    Morgenstern, Christian; Cabric, Sabrina; Perka, Carsten; Trampuz, Andrej; Renz, Nora

    2018-02-01

    Analysis of joint aspirate is the standard preoperative investigation for diagnosis of periprosthetic joint infection (PJI). We compared the diagnostic performance of culture and multiplex polymerase chain reaction (PCR) of synovial fluid for diagnosis of PJI. Patients in whom aspiration of the prosthetic hip or knee joint was performed before revision arthroplasty were prospectively included. The performance of synovial fluid culture and multiplex PCR was compared by McNemar's chi-squared test. A total of 142 patients were included, 82 with knee and 60 with hip prosthesis. PJI was diagnosed in 77 patients (54%) and aseptic failure in 65 patients (46%). The sensitivity of synovial fluid culture and PCR was 52% and 60%, respectively, showing concordant results in 116 patients (82%). In patients with PJI, PCR missed 6 high-virulent pathogens (S. aureus, streptococci, E. faecalis, E. coli) which grew in synovial fluid culture, whereas synovial fluid culture missed 12 pathogens detected by multiplex PCR, predominantly low-virulent pathogens (Cutibacterium acnes and coagulase-negative staphylococci). In patients with aseptic failure, PCR detected 6 low-virulent organisms (predominantly C. acnes). While the overall performance of synovial fluid PCR was comparable to culture, PCR was superior for detection of low-virulent bacteria such as Cutibacterium spp. and coagulase-negative staphylococci. In addition, synovial fluid culture required several days for growth, whereas multiplex PCR provided results within 5hours in an automated manner. Copyright © 2017 Elsevier Inc. All rights reserved.

  3. Exophiala (Wangiella dermatitidis Prosthetic Aortic Valve Endocarditis and Prosthetic Graft Infection in an Immune Competent Patient

    Directory of Open Access Journals (Sweden)

    Jay S. Berger

    2017-01-01

    Full Text Available Exophiala (Wangiella dermatitidis is an emerging dematiaceous fungus associated with high mortality rates and is a rare cause of endocarditis. We describe the first case of E. dermatitidis endocarditis of a prosthetic aortic valve and aortic graft in an immune competent patient with no clear risk factors of hematological acquisition.

  4. Detection of periprosthetic joint infections in presumed aseptic patients

    DEFF Research Database (Denmark)

    Xu, Yijuan; Lorenzen, Jan; Thomsen, Trine Rolighed

    2016-01-01

    Title: Detection of periprosthetic joint infections in presumed aseptic patients Yijuan Xu1, Jan Lorenzen1, Trine Rolighed Thomsen1,2, Kathrin Kluba3, Kathrin Chamaon3, Christoph Lohmann3 1. Danish Technological Institute, Aarhus, Denmark 2. Center for Microbial Communities, Department of Biotech......Title: Detection of periprosthetic joint infections in presumed aseptic patients Yijuan Xu1, Jan Lorenzen1, Trine Rolighed Thomsen1,2, Kathrin Kluba3, Kathrin Chamaon3, Christoph Lohmann3 1. Danish Technological Institute, Aarhus, Denmark 2. Center for Microbial Communities, Department...... of Biotechnology, Chemistry and Environmental Engineering, Aalborg University, Denmark 3. Department of Orthopaedics, Otto-von-Guericke University of Magdeburg, Germany Aim: ”The HypOrth project (New approaches in the development of Hypoallergenic implant material in Orthopaedics: Steps to personalised medicine......) aims to investigate adverse immune reactions to implant materials. For this project, it is of utmost importance to exclude patients with periprosthetic joint infections (PJIs). The aim of this study was to rule out PJIs in included patients using prolonged culture and next generation sequencing (NGS...

  5. Combined bone scintigraphy with 99mTc-MDP and 99mTc-ciprofloxacin in differentiation of hip and knee prosthesis aseptic loosening and infection: A preliminary study

    Directory of Open Access Journals (Sweden)

    Pucar Dragan

    2017-01-01

    Full Text Available Background/Aim. Although the number of new primary implantation of hip and knee prostheses every year increases, the rate of failed arthroplasty is nearly the same. The main question is whether it is an aseptic instability or instability caused by infection. The aim of this preliminary study was an attempt with combined 99mTc-ciprofloxacin and 99mTc-methylene diphosphonate (MDP bone scintigraphy to improve diagnostic accuracy in the differentiation of hip and knee prosthesis aseptic loosening and periprosthetic joint infection. Methods. Inclusion criteria of patients for this study were based on suspected periprosthetic joint infection: painful prosthetic joint, restricted joint movements and increased value of erythrocyte sedimentation rate or levels of C-reactive protein. We examined 20 patients with implanted 14 hip and 6 knee prosthesis. All patients also underwent plain radiography of suspected joint. In all patients, three-phase 99mTc-MDP bone scintigraphy was performed. Three to five days after the bone scan, we performed scintigraphy using 99mTc-ciprofloxacin with the calculation of accumulation index. Periprosthetic joint infection was confirmed on the basis of microbiological findings. Results. Periprosthetic joint infection was confirmed in fourteen of twenty observed joints, in five of them the aseptic loosening was present and in one patient’s symptoms were not related to the prosthesis (poor biomechanics of prosthetic joints caused by weaknesses of muscle. Estimated sensitivity/specificity for 99mTc-MDP bone scintigraphy alone were 100/17%; for 99mTc-ciprofloxacin scintigraphy were 85,7/100%. Sensitivity and specificity were 92,3% and 83,3%, respectively for results obtained with combined assessment by both methods. Our study confirmed the high negative predictive value of 99mTc-MDP bone scan. The negative result of bone scan virtually excludes the possibility of periprosthetic infection. On the other hand, positive findings of

  6. CT Assessment of the axial deviation of the femoral and tibial prosthetic components in total knee arthroplasty

    International Nuclear Information System (INIS)

    Rimondi, E.; Molinari, M.; Moio, A.; Busacca, M.; Trentani, F.; Trentani, P.; Tigani, D.; Nigrosoli, M.

    2000-01-01

    CT assessment of the axial deviation of the femoral and tibial prosthetic components in total knee arthroplasty. From January to July 1999, 17 patients, 10 males and 7 females, mean age 66 years (standard deviation plus or minus 4) were examined after total knee arthroplasty. Exclusion criteriawere prosthesis loosening and severe (equal or superior to 7'' varus o valgus deviation. All patients were examined with knee radiography in the standing position completed by axial projection of patella and by CT scanning. It was used a modification of Berger technique and carried out comparative CT scans extended lower limbs and acquisitions perpendicular to the mechanical axis of the knee, from the femoral supracondylar region down to the plane crossing the distal end of the tibial prosthetic component. Reference lines were then drawn electronically on given scanning planes to reckon the axial deviation of the femoral and tibial prosthetic components. Six patients, one female and 5 males with normal rotational values of femoral and tibial prosthetic components presented no clinical symptoms. Eight patients, 4 females and 4 males, with abnormal values presented the following clinical symptoms: medial impingement, (incomplete) dislocation patella, and lateral instability. One female patient with a normal rotational value of femoral prosthetic component and an altered value of tibial prosthetic component presented medial impingement. Finally two patients, one female and one male, were absolutely asymptomatic although the rotational values of the two prosthetic components were beyond the normal range. Total knee arthroplasty is presently a standard treatment for many conditions involving this joint. There are several possible postoperative complications, namely fractures, dislocations (a)septic losening and femoropatellar instability. The latter condition is the most frequent complication among implant failures and is caused by bad orientation of the femoral and tibial

  7. Measurement of installation deformation of the acetabulum during prosthetic replacement of a hip joint using digital image correlation

    Science.gov (United States)

    Lei, Dong; Bai, Pengxiang; Zhu, Feipeng

    2018-01-01

    Nowadays, acetabulum prosthesis replacement is widely used in clinical medicine. However, there is no efficient way to evaluate the implantation effect of the prosthesis. Based on a modern photomechanics technique called digital image correlation (DIC), the evaluation method of the installation effect of the acetabulum was established during a prosthetic replacement of a hip joint. The DIC method determines strain field by comparing the speckle images between the undeformed sample and the deformed counterpart. Three groups of experiments were carried out to verify the feasibility of the DIC method on the acetabulum installation deformation test. Experimental results indicate that the installation deformation of acetabulum generally includes elastic deformation (corresponding to the principal strain of about 1.2%) and plastic deformation. When the installation angle is ideal, the plastic deformation can be effectively reduced, which could prolong the service life of acetabulum prostheses.

  8. One-stage or two-stage revision surgery for prosthetic hip joint infection--the INFORM trial: a study protocol for a randomised controlled trial.

    Science.gov (United States)

    Strange, Simon; Whitehouse, Michael R; Beswick, Andrew D; Board, Tim; Burston, Amanda; Burston, Ben; Carroll, Fran E; Dieppe, Paul; Garfield, Kirsty; Gooberman-Hill, Rachael; Jones, Stephen; Kunutsor, Setor; Lane, Athene; Lenguerrand, Erik; MacGowan, Alasdair; Moore, Andrew; Noble, Sian; Simon, Joanne; Stockley, Ian; Taylor, Adrian H; Toms, Andrew; Webb, Jason; Whittaker, John-Paul; Wilson, Matthew; Wylde, Vikki; Blom, Ashley W

    2016-02-17

    Periprosthetic joint infection (PJI) affects approximately 1% of patients following total hip replacement (THR) and often results in severe physical and emotional suffering. Current surgical treatment options are debridement, antibiotics and implant retention; revision THR; excision of the joint and amputation. Revision surgery can be done as either a one-stage or two-stage operation. Both types of surgery are well-established practice in the NHS and result in similar rates of re-infection, but little is known about the impact of these treatments from the patient's perspective. The main aim of this randomised controlled trial is to determine whether there is a difference in patient-reported outcome measures 18 months after randomisation for one-stage or two-stage revision surgery. INFORM (INFection ORthopaedic Management) is an open, two-arm, multi-centre, randomised, superiority trial. We aim to randomise 148 patients with eligible PJI of the hip from approximately seven secondary care NHS orthopaedic units from across England and Wales. Patients will be randomised via a web-based system to receive either a one-stage revision or a two-stage revision THR. Blinding is not possible due to the nature of the intervention. All patients will be followed up for 18 months. The primary outcome is the WOMAC Index, which assesses hip pain, function and stiffness, collected by questionnaire at 18 months. Secondary outcomes include the following: cost-effectiveness, complications, re-infection rates, objective hip function assessment and quality of life. A nested qualitative study will explore patients' and surgeons' experiences, including their views about trial participation and randomisation. INFORM is the first ever randomised trial to compare two widely accepted surgical interventions for the treatment of PJI: one-stage and two-stage revision THR. The results of the trial will benefit patients in the future as the main focus is on patient-reported outcomes: pain, function

  9. Capnocytophaga canimorsus: a rare case of conservatively treated prosthetic valve endocarditis.

    Science.gov (United States)

    Jalava-Karvinen, Päivi; Grönroos, Juha O; Tuunanen, Helena; Kemppainen, Jukka; Oksi, Jarmo; Hohenthal, Ulla

    2018-05-01

    We describe a rare case of prosthetic valve endocarditis caused by the canine bacterium Capnocytophaga canimorsus in a male aged 73 years. The diagnosis of infective endocarditis was unequivocal, as it blood cultures were positive for C. canimorsus and vegetations were detected on transesophageal echocardiography; the modified Duke criteria were fulfilled. PET-CT showed intense 18 F-FDG uptake of the prosthetic valve area. The patient was treated with antibiotics alone (no surgery), and is now on life-long suppressive antibiotic therapy. To our knowledge, this is the third reported case of prosthetic valve endocarditis caused by C. canimorsus and the first one to have been treated conservatively. © 2018 APMIS. Published by John Wiley & Sons Ltd.

  10. Advanced upper limb prosthetic devices: implications for upper limb prosthetic rehabilitation.

    Science.gov (United States)

    Resnik, Linda; Meucci, Marissa R; Lieberman-Klinger, Shana; Fantini, Christopher; Kelty, Debra L; Disla, Roxanne; Sasson, Nicole

    2012-04-01

    The number of catastrophic injuries caused by improvised explosive devices in the Afghanistan and Iraq Wars has increased public, legislative, and research attention to upper limb amputation. The Department of Veterans Affairs (VA) has partnered with the Defense Advanced Research Projects Agency and DEKA Integrated Solutions to optimize the function of an advanced prosthetic arm system that will enable greater independence and function. In this special communication, we examine current practices in prosthetic rehabilitation including trends in adoption and use of prosthetic devices, financial considerations, and the role of rehabilitation team members in light of our experiences with a prototype advanced upper limb prosthesis during a VA study to optimize the device. We discuss key challenges in the adoption of advanced prosthetic technology and make recommendations for service provision and use of advanced upper limb prosthetics. Rates of prosthetic rejection are high among upper limb amputees. However, these rates may be reduced with sufficient training by a highly specialized, multidisciplinary team of clinicians, and a focus on patient education and empowerment throughout the rehabilitation process. There are significant challenges emerging that are unique to implementing the use of advanced upper limb prosthetic technology, and a lack of evidence to establish clinical guidelines regarding prosthetic prescription and treatment. Finally, we make recommendations for future research to aid in the identification of best practices and development of policy decisions regarding insurance coverage of prosthetic rehabilitation. Copyright © 2012 American Congress of Rehabilitation Medicine. Published by Elsevier Inc. All rights reserved.

  11. A Spontaneous Joint Infection with Corynebacterium striatum▿

    OpenAIRE

    Scholle, David

    2006-01-01

    Corynebacterium striatum is a ubiquitous saprophyte with the potential to cause bacteremia in immunocompromised patients. Until now, spontaneous infection of a natural joint has not been reported. When phenotyping failed, gene sequencing was used to identify the species. The isolate demonstrated high-level resistance to most antibiotics.

  12. Introduction to the Centers for Disease Control and Prevention and the Healthcare Infection Control Practices Advisory Committee Guideline for the Prevention of Surgical Site Infections.

    Science.gov (United States)

    Solomkin, Joseph S; Mazuski, John; Blanchard, Joan C; Itani, Kamal M F; Ricks, Philip; Dellinger, E Patchen; Allen, George; Kelz, Rachel; Reinke, Caroline E; Berríos-Torres, Sandra I

    Surgical site infection (SSI) is a common type of health-care-associated infection (HAI) and adds considerably to the individual, social, and economic costs of surgical treatment. This document serves to introduce the updated Guideline for the Prevention of SSI from the Centers for Disease Control and Prevention (CDC) and the Healthcare Infection Control Practices Advisory Committee (HICPAC). The Core section of the guideline addresses issues relevant to multiple surgical specialties and procedures. The second procedure-specific section focuses on a high-volume, high-burden procedure: Prosthetic joint arthroplasty. While many elements of the 1999 guideline remain current, others warrant updating to incorporate new knowledge and changes in the patient population, operative techniques, emerging pathogens, and guideline development methodology.

  13. Forced-air warming discontinued: periprosthetic joint infection rates drop

    Directory of Open Access Journals (Sweden)

    Scott D. Augustine

    2017-06-01

    Full Text Available Several studies have shown that the waste heat from forced-air warming (FAW escapes near the floor and warms the contaminated air resident near the floor. The waste heat then forms into convection currents that rise up and contaminate the sterile field above the surgical table. It has been shown that a single airborne bacterium can cause a periprosthetic joint infection (PJI following joint replacement surgery. We retrospectively compared PJI rates during a period of FAW to a period of air-free conductive fabric electric warming (CFW at three hospitals. Surgical and antibiotic protocols were held constant. The pooled multicenter data showed a decreased PJI rate of 78% following the discontinuation of FAW and a switch to air-free CFW (n=2034; P=0.002. The 78% reduction in joint implant infections observed when FAW was discontinued suggests that there is a link between the waste FAW heat and PJIs.

  14. Long-term clinical evaluation of the automatic stance-phase lock-controlled prosthetic knee joint in young adults with unilateral above-knee amputation.

    Science.gov (United States)

    Andrysek, Jan; Wright, F Virginia; Rotter, Karin; Garcia, Daniela; Valdebenito, Rebeca; Mitchell, Carlos Alvarez; Rozbaczylo, Claudio; Cubillos, Rafael

    2017-05-01

    The purpose of this study was to clinically evaluate the automatic stance-phase lock (ASPL) knee mechanism against participants' existing weight-activated braking (WAB) prosthetic knee joint. This prospective crossover study involved 10 young adults with an above-knee amputation. Primary measurements consisted of tests of walking speeds and capacity. Heart rate was measured during the six-minute walk test and the Physiological Cost Index (PCI) which was calculated from heart rate estimated energy expenditure. Activity was measured with a pedometer. User function and quality of life were assessed using the Lower Limb Function Questionnaire (LLFQ) and Prosthetic Evaluation Questionnaire (PEQ). Long-term follow-up over 12 months were completed. Walking speeds were the same for WAB and APSL knees. Energy expenditure (PCI) was lower for the ASPL knees (p = 0.007). Step counts were the same for both knees, and questionnaires indicated ASPL knee preference attributed primarily to knee stability and improved walking, while limitations included terminal impact noise. Nine of 10 participants chose to keep using the ASPL knee as part of the long-term follow-up. Potential benefits of the ASPL knee were identified in this study by functional measures, questionnaires and user feedback, but not changes in activity or the PEQ.

  15. Description of the rates, trends and surgical burden associated with revision for prosthetic joint infection following primary and revision knee replacements in England and Wales: an analysis of the National Joint Registry for England, Wales, Northern Ireland and the Isle of Man.

    Science.gov (United States)

    Lenguerrand, Erik; Whitehouse, Michael R; Beswick, Andrew D; Toms, Andrew D; Porter, Martyn L; Blom, Ashley W

    2017-07-10

    To describe the prevalence rates of revision surgery for the treatment of prosthetic joint infection (PJI) for patients undergoing knee replacement, their time trends, the cumulative incidence function of revision for PJI and estimate the burden of PJI at health service level. We analysed revision knee replacements performed due to a diagnosis of PJI and the linked index procedures recorded in the National Joint Registry from 2003 to 2014 for England and Wales. The cohort analysed consisted of 679 010 index primary knee replacements, 33 920 index revision knee replacements and 8247 revision total knee replacements performed due to a diagnosis of PJI. The prevalence rates, their time trends investigated by time from index surgery to revision for PJI, cumulative incidence functions and the burden of PJI (total procedures) were calculated. Overall linear trends were investigated with log-linear regression. The incidence of revision total knee replacement due to PJI at 2 years was 3.2/1000 following primary and 14.4/1000 following revision knee replacement, respectively. The prevalence of revision due to PJI in the 3 months following primary knee replacement has risen by 2.5-fold (95% CI 1.2 to 5.3) from 2005 to 2013 and 7.5-fold (95% CI 1.0 to 56.1) following revision knee replacement. Over 1000 procedures per year are performed as a consequence of knee PJI, an increase of 2.8 from 2005 to 2013. Overall, 75% of revisions were two-stage with an increase in use of single-stage from 7.9% in 2005 to 18.8% in 2014. Although the risk of revision due to PJI following knee replacement is low, it is rising, and coupled with the established and further predicted increased incidence of both primary and revision knee replacements, this represents an increasing and substantial treatment burden for orthopaedic service delivery in England and Wales. This has implications for future service design and the funding of individual and specialist centres. © Article author

  16. Uncemented allograft-prosthetic composite reconstruction of the proximal femur

    Directory of Open Access Journals (Sweden)

    Li Min

    2014-01-01

    Full Text Available Background: Allograft-prosthetic composite can be divided into three groups names cemented, uncemented, and partially cemented. Previous studies have mainly reported outcomes in cemented and partially cemented allograft-prosthetic composites, but have rarely focused on the uncemented allograft-prosthetic composites. The objectives of our study were to describe a surgical technique for using proximal femoral uncemented allograft-prosthetic composite and to present the radiographic and clinical results. Materials and Methods: Twelve patients who underwent uncemented allograft-prosthetic composite reconstruction of the proximal femur after bone tumor resection were retrospectively evaluated at an average followup of 24.0 months. Clinical records and radiographs were evaluated. Results: In our series, union occurred in all the patients (100%; range 5-9 months. Until the most recent followup, there were no cases with infection, nonunion of the greater trochanter, junctional bone resorption, dislocation, allergic reaction, wear of acetabulum socket, recurrence, and metastasis. But there were three periprosthetic fractures which were fixed using cerclage wire during surgery. Five cases had bone resorption in and around the greater trochanter. The average Musculoskeletal Tumor Society (MSTS score and Harris hip score (HHS were 26.2 points (range 24-29 points and 80.6 points (range 66.2-92.7 points, respectively. Conclusions: These results showed that uncemented allograft-prosthetic composite could promote bone union through compression at the host-allograft junction and is a good choice for proximal femoral resection. Although this technology has its own merits, long term outcomes are yet not validated.

  17. Prosthetic Leg Control in the Nullspace of Human Interaction.

    Science.gov (United States)

    Gregg, Robert D; Martin, Anne E

    2016-07-01

    Recent work has extended the control method of virtual constraints, originally developed for autonomous walking robots, to powered prosthetic legs for lower-limb amputees. Virtual constraints define desired joint patterns as functions of a mechanical phasing variable, which are typically enforced by torque control laws that linearize the output dynamics associated with the virtual constraints. However, the output dynamics of a powered prosthetic leg generally depend on the human interaction forces, which must be measured and canceled by the feedback linearizing control law. This feedback requires expensive multi-axis load cells, and actively canceling the interaction forces may minimize the human's influence over the prosthesis. To address these limitations, this paper proposes a method for projecting virtual constraints into the nullspace of the human interaction terms in the output dynamics. The projected virtual constraints naturally render the output dynamics invariant with respect to the human interaction forces, which instead enter into the internal dynamics of the partially linearized prosthetic system. This method is illustrated with simulations of a transfemoral amputee model walking with a powered knee-ankle prosthesis that is controlled via virtual constraints with and without the proposed projection.

  18. Aerogel Use as a Skin Protective Liner In Space Suits and Prosthetic Limbs Project

    Science.gov (United States)

    Roberson, Luke Bennett

    2014-01-01

    Existing materials for prosthetic liners tend to be thick and airtight, causing perspiration to accumulate inside the liner and potentially causing infection and injury. The purpose of this project was to examine the suitability of aerogel for prosthetic liner applications for use in space suits and orthopedics. Three tests were performed on several types of aerogel to assess the properties of each material, and our initial findings demonstrated that these materrials would be excellent candidates for liner applications for prosthetics and space suits. The project is currently on hold until additional funding is obtained for application testing at the VH Hospitals in Tampa

  19. Development of a prototype over-actuated biomimetic prosthetic hand.

    Directory of Open Access Journals (Sweden)

    Matthew R Williams

    Full Text Available The loss of a hand can greatly affect quality of life. A prosthetic device that can mimic normal hand function is very important to physical and mental recuperation after hand amputation, but the currently available prosthetics do not fully meet the needs of the amputee community. Most prosthetic hands are not dexterous enough to grasp a variety of shaped objects, and those that are tend to be heavy, leading to discomfort while wearing the device. In order to attempt to better simulate human hand function, a dexterous hand was developed that uses an over-actuated mechanism to form grasp shape using intrinsic joint mounted motors in addition to a finger tendon to produce large flexion force for a tight grip. This novel actuation method allows the hand to use small actuators for grip shape formation, and the tendon to produce high grip strength. The hand was capable of producing fingertip flexion force suitable for most activities of daily living. In addition, it was able to produce a range of grasp shapes with natural, independent finger motion, and appearance similar to that of a human hand. The hand also had a mass distribution more similar to a natural forearm and hand compared to contemporary prosthetics due to the more proximal location of the heavier components of the system. This paper describes the design of the hand and controller, as well as the test results.

  20. Fungal prosthetic valve endocarditis with mycotic aneurysm: Case report.

    Science.gov (United States)

    Brandão, Mariana; Almeida, Jorge; Ferraz, Rita; Santos, Lurdes; Pinho, Paulo; Casanova, Jorge

    2016-09-01

    Fungal prosthetic valve endocarditis is an extremely severe form of infective endocarditis, with poor prognosis and high mortality despite treatment. Candida albicans is the most common etiological agent for this rare but increasingly frequent condition. We present a case of fungal prosthetic valve endocarditis due to C. albicans following aortic and pulmonary valve replacement in a 38-year-old woman with a history of surgically corrected tetralogy of Fallot, prior infective endocarditis and acute renal failure with need for catheter-based hemodialysis. Antifungal therapy with liposomal amphotericin B was initiated prior to cardiac surgery, in which the bioprostheses were replaced by homografts, providing greater resistance to recurrent infection. During hospitalization, a mycotic aneurysm was diagnosed following an episode of acute arterial ischemia, requiring two vascular surgical interventions. Despite the complications, the patient's outcome was good and she was discharged on suppressive antifungal therapy with oral fluconazole for at least a year. The reported case illustrates multiple risk factors for fungal endocarditis, as well as complications and predictors of poor prognosis, demonstrating its complexity. Copyright © 2016 Sociedade Portuguesa de Cardiologia. Publicado por Elsevier España, S.L.U. All rights reserved.

  1. Graft infections after surgical aortic reconstructions

    NARCIS (Netherlands)

    Berger, P.

    2015-01-01

    Prosthetic vascular grafts are frequently used to reconstruct (part) of the aorta. Every surgical procedure caries a certain risk for infection and when a prosthetic aortic graft is implanted, this may lead to an aortic graft infection (AGI). Endovascular techniques have gradually replaced open

  2. A Mobile Motion Analysis System Using Intertial Sensors for Analysis of Lower Limb Prosthetics

    Energy Technology Data Exchange (ETDEWEB)

    Mueller, John Kyle P [ORNL; Ericson, Milton Nance [ORNL; Farquhar, Ethan [ORNL; Lind, Randall F [ORNL; Evans III, Boyd Mccutchen [ORNL

    2011-01-01

    Soldiers returning from the global war on terror requiring lower leg prosthetics generally have different concerns and requirements than the typical lower leg amputee. These subjects are usually young, wish to remain active and often desire to return to active military duty. As such, they demand higher performance from their prosthetics, but are at risk for chronic injury and joint conditions in their unaffected limb. Motion analysis is a valuable tool in assessing the performance of new and existing prosthetic technologies as well as the methods in fitting these devices to both maximize performance and minimize risk of injury for the individual soldier. We are developing a mobile, low-cost motion analysis system using inertial measurement units (IMUs) and two custom force sensors that detect ground reaction forces and moments on both the unaffected limb and prosthesis. IMUs were tested on a robot programmed to simulate human gait motion. An algorithm which uses a kinematic model of the robot and an extended Kalman filter (EKF) was used to convert the rates and accelerations from the gyro and accelerometer into joint angles. Compared to encoder data from the robot, which was considered the ground truth in this experiment, the inertial measurement system had a RMSE of <1.0 degree. Collecting kinematic and kinetic data without the restrictions and expense of a motion analysis lab could help researchers, designers and prosthetists advance prosthesis technology and customize devices for individuals. Ultimately, these improvements will result in better prosthetic performance for the military population.

  3. Aortic allografts in treatment of aortic valve and ascending aorta prosthetic endocarditis

    Directory of Open Access Journals (Sweden)

    S.V. Spiridonov

    2017-03-01

    Full Text Available The aim – to assess short- and long-term results of aortic root replacement using aortic allografts in patients with prosthetic endocarditis. Materials and methods. Since February 2009 until June 2016 aortic valve and ascending aorta replacement using aortic allografts was performed in 26 patients with prosthetic endocarditis. In 50 % of cases at initial operation aortic valve replacement was performed, in another 50 % of cases – aortic valve and ascending aorta replacement. Echocardiography was performed 10 days, 3, 6 and 12 months, 2, 3 and 5 years after surgery. Analysis of long-term results included all cases of deaths, prosthesis-related complications and recurrence of endocarditis. Results. 30-day mortality was 23.1 %. Extracorporeal membranous oxygenation (ECMO was used only in 5 patients (19.2 %. Four patients were weaned from ECMO. We did not observe any allograft-related complications. During follow-up period there were no cases of reoperation due to structural allograft failure. Relapse of infection occurred in 1 patient (3.8 % four years after the operation and led to lethal outcome. Conclusion. Reoperations using allografts are an effective surgical treatment of prosthetic endocarditis. In majority of cases prosthetic endocarditis was caused by gram-positive cocci (Staphylococcus. In 84.6 % of cases it was associated with destruction of paravalvular structures and abscesses formation. Heart failure was a causative factor of different complications in these patients, which required ECMO in 19.2 % of patients. In 80 % of cases patients were weaned from ECMO. Allografts using for the treatment of prosthetic endocarditis is associated with high resistance to infection and with a significant rate of freedom from recurrence of endocarditis within 3 years after surgery.

  4. An Evaluation of Dental Prosthetic Status and Prosthetic Needs ...

    African Journals Online (AJOL)

    present cross‑sectional study aimed to evaluate the dental prosthetic status and prosthetic needs among eunuchs .... who consented to become part of the study guided us to the .... to the reason that our study population comprised of adults with low SES. ... Arora M, Schwarz E, Sivaneswaran S, Banks E. Cigarette smoking.

  5. Developing and modeling of voice control system for prosthetic robot arm in medical systems

    Directory of Open Access Journals (Sweden)

    Koksal Gundogdu

    2018-04-01

    Full Text Available In parallel with the development of technology, various control methods are also developed. Voice control system is one of these control methods. In this study, an effective modelling upon mathematical models used in the literature is performed, and a voice control system is developed in order to control prosthetic robot arms. The developed control system has been applied on four-jointed RRRR robot arm. Implementation tests were performed on the designed system. As a result of the tests; it has been observed that the technique utilized in our system achieves about 11% more efficient voice recognition than currently used techniques in the literature. With the improved mathematical modelling, it has been shown that voice commands could be effectively used for controlling the prosthetic robot arm. Keywords: Voice recognition model, Voice control, Prosthetic robot arm, Robotic control, Forward kinematic

  6. Clinical features of anaerobic orthopaedic infections.

    Science.gov (United States)

    Lebowitz, Dan; Kressmann, Benjamin; Gjoni, Shpresa; Zenelaj, Besa; Grosgurin, Olivier; Marti, Christophe; Zingg, Matthieu; Uçkay, Ilker

    2017-02-01

    Some patient populations and types of orthopaedic surgery could be at particular risk for anaerobic infections. In this retrospective cohort study of operated adult patients with infections from 2004 to 2014, we assessed obligate anaerobes and considered first clinical infection episodes. Anaerobes, isolated from intra-operative samples, were identified in 2.4% of 2740 surgical procedures, of which half (33/65; 51%) were anaerobic monomicrobial infections. Propionibacterium acnes, a penicillin and vancomycin susceptible pathogen, was the predominantly isolated anaerobe. By multivariate analysis, the presence of fracture fixation plates was the variable most strongly associated with anaerobic infection (odds ratio: 2.1, 95% CI: 1.3-3.5). Anaerobes were also associated with spondylodesis and polymicrobial infections. In contrast, it revealed less likely in native bone or prosthetic joint infections and was not related to prior antibiotic use. In conclusion, obligate anaerobes in our case series of orthopaedic infections were rare, and mostly encountered in infections related to trauma with open-fracture fixation devices rather than clean surgical site infection. Anaerobes were often co-pathogens, and cultures most frequently recovered P. acnes. These observations thus do not support changes in current practices such as broader anaerobe coverage for perioperative prophylaxis.

  7. Efficacy of a novel strategy for poststernotomy deep sternal infection after thoracic aorta replacement using a prosthetic graft.

    Science.gov (United States)

    Kuriyama, Motone; Yoshida, Yukitaka; Ninomiya, Hitoshi; Yamamoto, Shin; Sasaguri, Shiro; Akita, Shinsuke; Mitsukawa, Nobuyuki

    2018-05-01

    Poststernotomy deep sternal wound infections are persistent and occasionally fatal, especially in cases involving prosthetic grafts, because of their complicated structure and virtual impossibility of removal. We aimed to verify the influence of cooperation with plastic surgeons and our novel strategy for treating deep sternal wound infection after aortic replacement on cardiovascular surgery outcomes. Nine hundred eighty-three consecutive patients were divided into two groups: an early group (2012-2013) and a late group (2014-2015). The late group had received cooperatively improved perioperative wound management: our novel strategy of deep sternal infection based on radical debridement and immediate reconstruction decided by reference to severities of the patient's general condition and widespread infection by early intervention of plastic surgeons. The groups were analysed retrospectively. Binary variables were analysed statistically with the Fisher exact test and continuous variables with the Mann-Whitney U test. Inter-group differences were assessed with the chi-square test. Twenty of 390 cases in the early group and 13 of 593 cases in the late group were associated with deep sternal infection. Morbidity rates of deep sternal wound infection and associated mortality rates 1 year after reconstruction surgery were significantly less (p infection also reduced associated mortality rates. Facilities should consider the early inclusion of plastic surgeons in the treatment of patients undergoing aortic replacement to facilitate better outcomes. Copyright © 2018 British Association of Plastic, Reconstructive and Aesthetic Surgeons. Published by Elsevier Ltd. All rights reserved.

  8. Illusory movement perception improves motor control for prosthetic hands

    Science.gov (United States)

    Marasco, Paul D.; Hebert, Jacqueline S.; Sensinger, Jon W.; Shell, Courtney E.; Schofield, Jonathon S.; Thumser, Zachary C.; Nataraj, Raviraj; Beckler, Dylan T.; Dawson, Michael R.; Blustein, Dan H.; Gill, Satinder; Mensh, Brett D.; Granja-Vazquez, Rafael; Newcomb, Madeline D.; Carey, Jason P.; Orzell, Beth M.

    2018-01-01

    To effortlessly complete an intentional movement, the brain needs feedback from the body regarding the movement’s progress. This largely non-conscious kinesthetic sense helps the brain to learn relationships between motor commands and outcomes to correct movement errors. Prosthetic systems for restoring function have predominantly focused on controlling motorized joint movement. Without the kinesthetic sense, however, these devices do not become intuitively controllable. Here we report a method for endowing human amputees with a kinesthetic perception of dexterous robotic hands. Vibrating the muscles used for prosthetic control via a neural-machine interface produced the illusory perception of complex grip movements. Within minutes, three amputees integrated this kinesthetic feedback and improved movement control. Combining intent, kinesthesia, and vision instilled participants with a sense of agency over the robotic movements. This feedback approach for closed-loop control opens a pathway to seamless integration of minds and machines. PMID:29540617

  9. Psychophysical testing of visual prosthetic devices: a call to establish a multi-national joint task force

    Science.gov (United States)

    Rizzo, Joseph F., III; Ayton, Lauren N.

    2014-04-01

    Recent advances in the field of visual prostheses, as showcased in this special feature of Journal of Neural Engineering , have led to promising results from clinical trials of a number of devices. However, as noted by these groups there are many challenges involved in assessing vision of people with profound vision loss. As such, it is important that there is consistency in the methodology and reporting standards for clinical trials of visual prostheses and, indeed, the broader vision restoration research field. Two visual prosthesis research groups, the Boston Retinal Implant Project (BRIP) and Bionic Vision Australia (BVA), have agreed to work cooperatively to establish a multi-national Joint Task Force. The aim of this Task Force will be to develop a consensus statement to guide the methods used to conduct and report psychophysical and clinical results of humans who receive visual prosthetic devices. The overarching goal is to ensure maximum benefit to the implant recipients, not only in the outcomes of the visual prosthesis itself, but also in enabling them to obtain accurate information about this research with ease. The aspiration to develop a Joint Task Force was first promulgated at the inaugural 'The Eye and the Chip' meeting in September 2000. This meeting was established to promote the development of the visual prosthetic field by applying the principles of inclusiveness, openness, and collegiality among the growing body of researchers in this field. These same principles underlie the intent of this Joint Task Force to enhance the quality of psychophysical research within our community. Despite prior efforts, a critical mass of interested parties could not congeal. Renewed interest for developing joint guidelines has developed recently because of a growing awareness of the challenges of obtaining reliable measurements of visual function in patients who are severely visually impaired (in whom testing is inherently noisy), and of the importance of

  10. Computed Tomography of the complications of prosthetic surgery of the abdominal aorta

    International Nuclear Information System (INIS)

    Giovagnorio, Francesco; Andreoli, Chiara; De Cicco, Maria Luisa

    1997-01-01

    Computerized Tomography has gained an important role in the diagnosis of the complications of prosthetic surgery of the abdominal aorta: the importance of such complications come from their frequency, which is proportional to the increasing number of interventions, and their severity. The authors investigated the CT patterns of the most frequent complications. 24 patients referred for strongly suspected postoperative complications were examined in 2 years: fever and leukocytosis (20 cases) and progressive anemia (4 cases) were the most frequent findings. The operation had been performed 7± 12 weeks before (2 patients were excluded because surgery dated less than 3 weeks. 14 patients had infective complications: thickening (57%) and inhomogeneity (43%) of the periprosthetic wrap and ectopic gas bubble (78%) were the most frequent Computerized Tomography findings. The authors also observed 2 periprosthetic hematomas, 1 aneurysm relapse and 1 prosthetic graft rupture. In conclusion, CT confirmed its important role in the study of the complications of prosthetic aortic surgery, despite its know poor specificity in the demonstration of the aorta in the first 2-3 months postoperatively, in the initial stages of infection and in the diagnosis of aorta-enteric fistulas

  11. Computed tomography of human joints and radioactive waste drums

    International Nuclear Information System (INIS)

    Martz, Harry E.; Roberson, G. Patrick; Hollerbach, Karin; Logan, Clinton M.; Ashby, Elaine; Bernardi, Richard

    1999-01-01

    X- and gamma-ray imaging techniques in nondestructive evaluation (NDE) and assay (NDA) have seen increasing use in an array of industrial, environmental, military, and medical applications. Much of this growth in recent years is attributed to the rapid development of computed tomography (CT) and the use of NDE throughout the life-cycle of a product. Two diverse examples of CT are discussed, 1.) Our computational approach to normal joint kinematics and prosthetic joint analysis offers an opportunity to evaluate and improve prosthetic human joint replacements before they are manufactured or surgically implanted. Computed tomography data from scanned joints are segmented, resulting in the identification of bone and other tissues of interest, with emphasis on the articular surfaces. 2.) We are developing NDE and NDA techniques to analyze closed waste drums accurately and quantitatively. Active and passive computed tomography (A and PCT) is a comprehensive and accurate gamma-ray NDA method that can identify all detectable radioisotopes present in a container and measure their radioactivity

  12. Early prosthetic valve endocarditis caused by Corynebacterium kroppenstedtii.

    Science.gov (United States)

    Hagemann, Jürgen Benjamin; Essig, Andreas; Herrmann, Manuel; Liebold, Andreas; Quader, Mohamed Abo

    2015-12-01

    Corynebacterium (C.) kroppenstedtii is a rarely detected agent of bacterial infections in humans. Here, we describe the first case of prosthetic valve endocarditis caused by C. kroppenstedtii. Application of molecular methods using surgically excised valve tissue was a cornerstone for the establishment of the microbiological diagnosis, which is crucial for targeted antimicrobial treatment. Copyright © 2015 Elsevier GmbH. All rights reserved.

  13. 21 CFR 888.3400 - Hip joint femoral (hemi-hip) metallic resurfacing prosthesis.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Hip joint femoral (hemi-hip) metallic resurfacing... HUMAN SERVICES (CONTINUED) MEDICAL DEVICES ORTHOPEDIC DEVICES Prosthetic Devices § 888.3400 Hip joint femoral (hemi-hip) metallic resurfacing prosthesis. (a) Identification. A hip joint femoral (hemi-hip...

  14. 21 CFR 888.3370 - Hip joint (hemi-hip) acetabular metal cemented prosthesis.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Hip joint (hemi-hip) acetabular metal cemented... HUMAN SERVICES (CONTINUED) MEDICAL DEVICES ORTHOPEDIC DEVICES Prosthetic Devices § 888.3370 Hip joint (hemi-hip) acetabular metal cemented prosthesis. (a) Identification. A hip joint (hemi-hip) acetabular...

  15. 21 CFR 888.3350 - Hip joint metal/polymer semi-constrained cemented prosthesis.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Hip joint metal/polymer semi-constrained cemented... HUMAN SERVICES (CONTINUED) MEDICAL DEVICES ORTHOPEDIC DEVICES Prosthetic Devices § 888.3350 Hip joint metal/polymer semi-constrained cemented prosthesis. (a) Identification. A hip joint metal/polymer semi...

  16. 21 CFR 888.3300 - Hip joint metal constrained cemented or uncemented prosthesis.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Hip joint metal constrained cemented or uncemented... HUMAN SERVICES (CONTINUED) MEDICAL DEVICES ORTHOPEDIC DEVICES Prosthetic Devices § 888.3300 Hip joint metal constrained cemented or uncemented prosthesis. (a) Identification. A hip joint metal constrained...

  17. 21 CFR 888.3570 - Knee joint femoral (hemi-knee) metallic uncemented prosthesis.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Knee joint femoral (hemi-knee) metallic uncemented... HUMAN SERVICES (CONTINUED) MEDICAL DEVICES ORTHOPEDIC DEVICES Prosthetic Devices § 888.3570 Knee joint femoral (hemi-knee) metallic uncemented prosthesis. (a) Identification. A knee joint femoral (hemi-knee...

  18. 21 CFR 888.3120 - Ankle joint metal/polymer non-constrained cemented prosthesis.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Ankle joint metal/polymer non-constrained cemented... HUMAN SERVICES (CONTINUED) MEDICAL DEVICES ORTHOPEDIC DEVICES Prosthetic Devices § 888.3120 Ankle joint metal/polymer non-constrained cemented prosthesis. (a) Identification. An ankle joint metal/polymer non...

  19. 21 CFR 872.3940 - Total temporomandibular joint prosthesis.

    Science.gov (United States)

    2010-04-01

    ... (CONTINUED) MEDICAL DEVICES DENTAL DEVICES Prosthetic Devices § 872.3940 Total temporomandibular joint... implanted in the human jaw to replace the mandibular condyle and augment the glenoid fossa to functionally...

  20. Prosthetic radioiodination of interleukin-8 ([123/131I]-IL-8): biological behavior in a mouse infection model

    International Nuclear Information System (INIS)

    Amartey, J.K.; Esguerra, C.; Al-Otaibi, B.; Al-Jammaz, I.; Al-Qahtani, M.; Parhar, R.S.

    2005-01-01

    Numerous molecular entities with diverse structures have been radiolabeled and investigated as potential infection and inflammation detection agents. However, none of these molecules have gained the acceptance of gallium citrate or radiolabeled autologous white blood cells. We have radioiodinated interleukin-8 using two different methods and tested the biological behavior of the products in mice. As expected, the direct radioiodinated material displayed extensive in vivo deiodination. The use of pyridine-based prosthetic label yielded a product with better kinetics than the direct radioiodination method and showed a better target to non-target ratio. Nonetheless, this method is not suited for labeling of bioactive peptides such as the title peptide because of the very high specific activity required to prevent cytotoxic effects in a human application

  1. Virtual Constraint Control of a Powered Prosthetic Leg: From Simulation to Experiments with Transfemoral Amputees.

    Science.gov (United States)

    Gregg, Robert D; Lenzi, Tommaso; Hargrove, Levi J; Sensinger, Jonathon W

    2014-12-01

    Recent powered (or robotic) prosthetic legs independently control different joints and time periods of the gait cycle, resulting in control parameters and switching rules that can be difficult to tune by clinicians. This challenge might be addressed by a unifying control model used by recent bipedal robots, in which virtual constraints define joint patterns as functions of a monotonic variable that continuously represents the gait cycle phase. In the first application of virtual constraints to amputee locomotion, this paper derives exact and approximate control laws for a partial feedback linearization to enforce virtual constraints on a prosthetic leg. We then encode a human-inspired invariance property called effective shape into virtual constraints for the stance period. After simulating the robustness of the partial feedback linearization to clinically meaningful conditions, we experimentally implement this control strategy on a powered transfemoral leg. We report the results of three amputee subjects walking overground and at variable cadences on a treadmill, demonstrating the clinical viability of this novel control approach.

  2. Fused Filament Fabrication of Prosthetic Components for Trans-Humeral Upper Limb Prosthetics

    Science.gov (United States)

    Lathers, Steven M.

    Presented below is the design and fabrication of prosthetic components consisting of an attachment, tactile sensing, and actuator systems with Fused Filament Fabrication (FFF) technique. The attachment system is a thermoplastic osseointegrated upper limb prosthesis for average adult trans-humeral amputation with mechanical properties greater than upper limb skeletal bone. The prosthetic designed has: a one-step surgical process, large cavities for bone tissue ingrowth, uses a material that has an elastic modulus less than skeletal bone, and can be fabricated on one system. FFF osseointegration screw is an improvement upon the current two-part osseointegrated prosthetics that are composed of a fixture and abutment. The current prosthetic design requires two invasive surgeries for implantation and are made of titanium, which has an elastic modulus greater than bone. An elastic modulus greater than bone causes stress shielding and overtime can cause loosening of the prosthetic. The tactile sensor is a thermoplastic piezo-resistive sensor for daily activities for a prosthetic's feedback system. The tactile sensor is manufactured from a low elastic modulus composite comprising of a compressible thermoplastic elastomer and conductive carbon. Carbon is in graphite form and added in high filler ratios. The printed sensors were compared to sensors that were fabricated in a gravity mold to highlight the difference in FFF sensors to molded sensors. The 3D printed tactile sensor has a thickness and feel similar to human skin, has a simple fabrication technique, can detect forces needed for daily activities, and can be manufactured in to user specific geometries. Lastly, a biomimicking skeletal muscle actuator for prosthetics was developed. The actuator developed is manufactured with Fuse Filament Fabrication using a shape memory polymer composite that has non-linear contractile and passive forces, contractile forces and strains comparable to mammalian skeletal muscle, reaction

  3. Three cases of severely disseminated Staphylococcus aureus infection in patients treated with tocilizumab

    DEFF Research Database (Denmark)

    Nguyen, Mai; Pødenphant, Jan; Ravn, Pernille

    2013-01-01

    -intensive diagnostic work-up and early treatment should be performed. Systematic postmarketing studies are needed to clarify if there is a true increased risk of disseminated S aureus infections. We suggest caution when prescribing tocilizumab to patients with prosthetic joints and/or prior invasive S aureus......We report three cases of severe disseminated Staphylococcus aureus infection in patients with rheumatoid arthritis (RA) treated with tocilizumab. Tocilizumab is a new drug, unknown to most internists, and injections given weeks before admission may not be considered by the patient as part...... of their 'current medical treatment', and the physician may not be aware that the patient is severely immunosuppressed. Severe infections in RA patients treated with tocilizumab may present with mild symptoms despite severe and disseminated infection and, as these patients are severely immunodeficient...

  4. A rare case of prosthetic endocarditis and dehiscence in a mechanical valved conduit.

    Science.gov (United States)

    Kannan, Arun; Smith, Cristy; Subramanian, Sreekumar; Janardhanan, Rajesh

    2014-02-07

    A middle-aged adult patient with a history of aortic root replacement with a mechanical valved conduit and remote chest trauma was referred to our institution with prosthetic endocarditis. Transoesophageal echocardiogram at our institution confirmed a near-complete dehiscence of the prosthetic aortic valve from the conduit, with significant perivalvular flow forming a pseudoaneurysm. The patient underwent a high-risk re-operation, involving redo aortic root replacement with a homograft after extensive debridement of the infected tissue. The patient was discharged to an outside facility after an uncomplicated hospital course, and remains stable.

  5. Prevention of Prosthetic Dentistry

    Directory of Open Access Journals (Sweden)

    Eremin O.V.

    2011-03-01

    Full Text Available Prevention in prosthetic dentistry is not just a regular oral hygiene and the prevention of caries in the early stages of its development. The initial goal of orthopedic and dental should be the ability to convey to the patient's sense of pros-thetics that proteziruya one saved more. An example is included prosthetic dental arch defects with bridges or single artificial crowns on implants that will prevent movement of teeth and the continuity of the dentition

  6. Are homografts superior to conventional prosthetic valves in the setting of infective endocarditis involving the aortic valve?

    Science.gov (United States)

    Kim, Joon Bum; Ejiofor, Julius I; Yammine, Maroun; Camuso, Janice M; Walsh, Conor W; Ando, Masahiko; Melnitchouk, Serguei I; Rawn, James D; Leacche, Marzia; MacGillivray, Thomas E; Cohn, Lawrence H; Byrne, John G; Sundt, Thoralf M

    2016-05-01

    Surgical dogma suggests that homografts should be used preferentially, compared with conventional xenograft or mechanical prostheses, in the setting of infective endocarditis (IE), because they have greater resistance to infection. However, comparative data that support this notion are limited. From the prospective databases of 2 tertiary academic centers, we identified 304 consecutive adult patients (age ≥17 years) who underwent surgery for active IE involving the aortic valve (AV), in the period 2002 to 2014. Short- and long-term outcomes were evaluated using propensity scores and inverse-probability weighting to adjust for selection bias. Homografts, and xenograft and mechanical prostheses, were used in 86 (28.3%), 139 (45.7%), and 79 (26.0%) patients, respectively. Homografts were more often used in the setting of prosthetic valve endocarditis (58.1% vs 28.8%, P = .002) and methicillin-resistant Staphylococcus (25.6% vs 12.1%, P = .002), compared with conventional prostheses. Early mortality occurred in 17 (19.8%) in the homograft group, and 20 (9.2%) in the conventional group (P = .019). During follow-up (median: 29.4 months; interquartile-range: 4.7-72.6 months), 60 (19.7%) patients died, and 23 (7.7%) experienced reinfection, with no significant differences in survival (P = .23) or freedom from reinfection rates (P = .65) according to the types of prostheses implanted. After adjustments for baseline characteristics, using propensity-score analyses, use of a homograft did not significantly affect early death (odds ratio 1.61; 95% confidence interval [CI], 0.73-3.40, P = .23), overall death (hazard ratio 1.10; 95% CI, 0.62-1.94, P = .75), or reinfection (hazard ratio 1.04; 95% CI, 0.49-2.18, P = .93). No significant benefit to use of homografts was demonstrable with regard to resistance to reinfection in the setting of IE. The choice among prosthetic options should be based on technical and patient-specific factors. Lack of availability of homografts should

  7. Systematic variation of prosthetic foot spring affects center-of-mass mechanics and metabolic cost during walking.

    Science.gov (United States)

    Zelik, Karl E; Collins, Steven H; Adamczyk, Peter G; Segal, Ava D; Klute, Glenn K; Morgenroth, David C; Hahn, Michael E; Orendurff, Michael S; Czerniecki, Joseph M; Kuo, Arthur D

    2011-08-01

    Lower-limb amputees expend more energy to walk than non-amputees and have an elevated risk of secondary disabilities. Insufficient push-off by the prosthetic foot may be a contributing factor. We aimed to systematically study the effect of prosthetic foot mechanics on gait, to gain insight into fundamental prosthetic design principles. We varied a single parameter in isolation, the energy-storing spring in a prototype prosthetic foot, the controlled energy storage and return (CESR) foot, and observed the effect on gait. Subjects walked on the CESR foot with three different springs. We performed parallel studies on amputees and on non-amputees wearing prosthetic simulators. In both groups, spring characteristics similarly affected ankle and body center-of-mass (COM) mechanics and metabolic cost. Softer springs led to greater energy storage, energy return, and prosthetic limb COM push-off work. But metabolic energy expenditure was lowest with a spring of intermediate stiffness, suggesting biomechanical disadvantages to the softest spring despite its greater push-off. Disadvantages of the softest spring may include excessive heel displacements and COM collision losses. We also observed some differences in joint kinetics between amputees and non-amputees walking on the prototype foot. During prosthetic push-off, amputees exhibited reduced energy transfer from the prosthesis to the COM along with increased hip work, perhaps due to greater energy dissipation at the knee. Nevertheless, the results indicate that spring compliance can contribute to push-off, but with biomechanical trade-offs that limit the degree to which greater push-off might improve walking economy. © 2011 IEEE

  8. Risk factors and outcomes for nosocomial infection after prosthetic vascular grafts.

    Science.gov (United States)

    Fariñas, María Carmen; Campo, Ana; Duran, Raquel; Sarralde, José Aurelio; Nistal, Juan Francisco; Gutiérrez-Díez, José Francisco; Fariñas-Álvarez, Concepción

    2017-11-01

    The objective of this study was to determine risk factors for nosocomial infections (NIs) and predictors of mortality in patients with prosthetic vascular grafts (PVGs). This was a prospective cohort study of all consecutive patients who underwent PVG of the abdominal aorta with or without iliac-femoral involvement and peripheral PVG from April 2008 to August 2009 at a university hospital. Patients younger than 15 years and those with severe immunodeficiency were excluded. The follow-up period was until 3 years after surgery or until death. There were 261 patients included; 230 (88.12%) were male, and the mean age was 67.57 (standard deviation, 10.82) years. The reason for operation was aortic aneurysm in 49 (18.77%) patients or lower limb arteriopathy in 212 (81.23%) patients. NIs occurred in 71 (27.20%) patients. Of these, 42 were surgical site infections (SSIs), of which 61.9% occurred in the lower extremities (14 superficial, 10 deep, and 2 PVG infections) and 38.1% in the abdomen (7 superficial, 7 deep, and 2 PVG infections); 15 were respiratory tract infections; and 15 were urinary tract infections. Active lower extremity skin and soft tissue infection (SSTI) at the time of surgery was a significant predictor of NI for both types of PVG (abdominal aortic PVG: adjusted odds ratio [OR], 12.6; 95% confidence interval [CI], 1.15-138.19; peripheral PVG: adjusted OR, 2.43; 95% CI, 1.08-5.47). Other independent predictors of NI were mechanical ventilation (adjusted OR, 55.96; 95% CI, 3.9-802.39) for abdominal aortic PVG and low hemoglobin levels on admission (adjusted OR, 0.84; 95% CI, 0.71-0.99) and emergent surgery (adjusted OR, 4.39; 95% CI, 1.51-12.74) for peripheral PVG. The in-hospital mortality rate was 1.92%. The probability of surviving the first month was 0.96, and significant predictors of mortality were active lower extremity SSTI (adjusted risk ratio [RR], 12.07; 95% CI, 1.04-154.75), high postsurgical glucose levels (adjusted RR, 1.02; 95% CI, 1

  9. Prosthetic component segmentation with blur compensation: a fast method for 3D fluoroscopy.

    Science.gov (United States)

    Tarroni, Giacomo; Tersi, Luca; Corsi, Cristiana; Stagni, Rita

    2012-06-01

    A new method for prosthetic component segmentation from fluoroscopic images is presented. The hybrid approach we propose combines diffusion filtering, region growing and level-set techniques without exploiting any a priori knowledge of the analyzed geometry. The method was evaluated on a synthetic dataset including 270 images of knee and hip prosthesis merged to real fluoroscopic data simulating different conditions of blurring and illumination gradient. The performance of the method was assessed by comparing estimated contours to references using different metrics. Results showed that the segmentation procedure is fast, accurate, independent on the operator as well as on the specific geometrical characteristics of the prosthetic component, and able to compensate for amount of blurring and illumination gradient. Importantly, the method allows a strong reduction of required user interaction time when compared to traditional segmentation techniques. Its effectiveness and robustness in different image conditions, together with simplicity and fast implementation, make this prosthetic component segmentation procedure promising and suitable for multiple clinical applications including assessment of in vivo joint kinematics in a variety of cases.

  10. Pre-operative antiseptic shower and bath policy decreases the rate of S. aureus and methicillin-resistant S. aureus surgical site infections in patients undergoing joint arthroplasty.

    Science.gov (United States)

    Colling, Kristin; Statz, Catherine; Glover, James; Banton, Kaysie; Beilman, Greg

    2015-04-01

    Surgical site infection (SSI) following joint arthroplasty increases length of stay, hospital cost, and leads to patient and healthcare provider dissatisfaction. Due to the presence of non-biologic implants (the prosthetic joint) in these procedures, infection is often devastating and treatment of the infection is more difficult. For this reason, prevention of SSI is of crucial importance in this population. Staphylococcus aureus colonizes the nares of approximately 30-40% of the population, is the most common pathogen causing SSI, and is associated with high morbidity and mortality rate. A pre-operative shower or bath with an antiseptic is an inexpensive and effective method of removal of these transient skin pathogens prior to the procedure and may be used to decrease SSI. We hypothesize that a preoperative antiseptic shower or bath will decrease the rate of SSI. A retrospective review was performed at two affiliated hospitals within the same system, one with a hospital-wide policy enforcing pre-operative antiseptic shower or bath and the other with no policy, with cases included from January 2010 to June 2012. International Classification of Disease-Ninth Revision-Clinical Modification (ICD-9-CM) codes and chart review were used to identify patients undergoing joint arthroplasty and to identify those with SSI. Two thousand three-hundred forty-nine arthroplasties were performed at the University of Minnesota Medical Center, a tertiary-care hospital with a pre-operative antiseptic shower or bath policy in place. An additional 1,693 procedures were performed at Fairview Ridges Hospital, a community hospital with no pre-operative policy. There was no difference in the rate of SSI between the two hospitals (1.96% vs. 1.95%; p=1.0). However, the rate of SSI caused by S. aureus was significantly decreased by pre-operative antiseptic shower/bath (17% vs. 61%; p=0.03), as was the rate of methicillin-resistant S. aureus (MRSA) infections (2% vs. 24% p=0.002). A pre

  11. Prosthetic radioiodination of interleukin-8 ([{sup 123/131}I]-IL-8): biological behavior in a mouse infection model

    Energy Technology Data Exchange (ETDEWEB)

    Amartey, J.K. [Cyclotron and Radiopharmaceuticals Department, King Faisal Specialist Hospital and Research Centre, MBC-03, P.O. Box 3354, Riyadh 11211 (Saudi Arabia)]. E-mail: amarty@kfshrc.edu.sa; Esguerra, C. [Cyclotron and Radiopharmaceuticals Department, King Faisal Specialist Hospital and Research Centre, MBC-03, P.O. Box 3354, Riyadh 11211 (Saudi Arabia); Al-Otaibi, B. [Cyclotron and Radiopharmaceuticals Department, King Faisal Specialist Hospital and Research Centre, MBC-03, P.O. Box 3354, Riyadh 11211 (Saudi Arabia); Al-Jammaz, I. [Cyclotron and Radiopharmaceuticals Department, King Faisal Specialist Hospital and Research Centre, MBC-03, P.O. Box 3354, Riyadh 11211 (Saudi Arabia); Al-Qahtani, M. [Cyclotron and Radiopharmaceuticals Department, King Faisal Specialist Hospital and Research Centre, MBC-03, P.O. Box 3354, Riyadh 11211 (Saudi Arabia); Parhar, R.S. [Cyclotron and Radiopharmaceuticals Department, King Faisal Specialist Hospital and Research Centre, MBC-03, P.O. Box 3354, Riyadh 11211 (Saudi Arabia)

    2005-01-01

    Numerous molecular entities with diverse structures have been radiolabeled and investigated as potential infection and inflammation detection agents. However, none of these molecules have gained the acceptance of gallium citrate or radiolabeled autologous white blood cells. We have radioiodinated interleukin-8 using two different methods and tested the biological behavior of the products in mice. As expected, the direct radioiodinated material displayed extensive in vivo deiodination. The use of pyridine-based prosthetic label yielded a product with better kinetics than the direct radioiodination method and showed a better target to non-target ratio. Nonetheless, this method is not suited for labeling of bioactive peptides such as the title peptide because of the very high specific activity required to prevent cytotoxic effects in a human application.

  12. Total Hip Arthroplasty Loosening Due to Mycobacterium Tuberculosis: A Case Report and Review of the Literature

    Directory of Open Access Journals (Sweden)

    Anis Tebourbi

    2017-04-01

    Full Text Available Context: Prosthetic joint infection due to Mycobacterium tuberculosis with no previous history of pulmonary or extra pulmonary tuberculosis is an extremely rare complication. Aims To report the case of a patient with tuberculous mycobacterial prosthetic hip infection, 14 years after surgery for post traumatic osteoarthritis, with no previous history of tuberculosis. Methods A 46-year-old male presented an acetabular loosening of a cemented total hip arthroplasty with subnormal biologic parameters. A one stage revision surgery was planned. Intraoperative findings suggested mycobacterial tuberculous infection with presence of periacetabular yellowish rice-shaped granules. Results A one-stage prosthesis exchange was performed; Culture on Löwenstein-Jensen medium grew MTB days after inoculation and histological examination confirmed tuberculous infection. Patient was treated by antituberculous agents for 12 months with optimal clinical and biological response and no prosthetic loosening signs at eighteen months follow up. Conclusions Total hip arthroplasty loosening due to mycobacterium tuberculosis is a rare entity, which should be evoked even when no inflammatory signs are shown. Discovery of yellowish rice-shaped granules is an indicator to investigate for tuberculosis. Management of prosthetic joint infection due to M.tuberculosis must involve both medical and surgical approach.

  13. Graft infections after surgical aortic reconstructions

    OpenAIRE

    Berger, P.

    2015-01-01

    Prosthetic vascular grafts are frequently used to reconstruct (part) of the aorta. Every surgical procedure caries a certain risk for infection and when a prosthetic aortic graft is implanted, this may lead to an aortic graft infection (AGI). Endovascular techniques have gradually replaced open surgical reconstructions as first line of treatment for aorto-iliac diseases. Nowadays, open reconstructions are primarily reserved for patients unsuitable for endovascular reconstructions or for redo ...

  14. Illusory movement perception improves motor control for prosthetic hands.

    Science.gov (United States)

    Marasco, Paul D; Hebert, Jacqueline S; Sensinger, Jon W; Shell, Courtney E; Schofield, Jonathon S; Thumser, Zachary C; Nataraj, Raviraj; Beckler, Dylan T; Dawson, Michael R; Blustein, Dan H; Gill, Satinder; Mensh, Brett D; Granja-Vazquez, Rafael; Newcomb, Madeline D; Carey, Jason P; Orzell, Beth M

    2018-03-14

    To effortlessly complete an intentional movement, the brain needs feedback from the body regarding the movement's progress. This largely nonconscious kinesthetic sense helps the brain to learn relationships between motor commands and outcomes to correct movement errors. Prosthetic systems for restoring function have predominantly focused on controlling motorized joint movement. Without the kinesthetic sense, however, these devices do not become intuitively controllable. We report a method for endowing human amputees with a kinesthetic perception of dexterous robotic hands. Vibrating the muscles used for prosthetic control via a neural-machine interface produced the illusory perception of complex grip movements. Within minutes, three amputees integrated this kinesthetic feedback and improved movement control. Combining intent, kinesthesia, and vision instilled participants with a sense of agency over the robotic movements. This feedback approach for closed-loop control opens a pathway to seamless integration of minds and machines. Copyright © 2018 The Authors, some rights reserved; exclusive licensee American Association for the Advancement of Science. No claim to original U.S. Government Works.

  15. The effects of a controlled energy storage and return prototype prosthetic foot on transtibial amputee ambulation.

    Science.gov (United States)

    Segal, Ava D; Zelik, Karl E; Klute, Glenn K; Morgenroth, David C; Hahn, Michael E; Orendurff, Michael S; Adamczyk, Peter G; Collins, Steven H; Kuo, Arthur D; Czerniecki, Joseph M

    2012-08-01

    The lack of functional ankle musculature in lower limb amputees contributes to the reduced prosthetic ankle push-off, compensations at other joints and more energetically costly gait commonly observed in comparison to non-amputees. A variety of energy storing and return prosthetic feet have been developed to address these issues but have not been shown to sufficiently improve amputee biomechanics and energetic cost, perhaps because the timing and magnitude of energy return is not controlled. The goal of this study was to examine how a prototype microprocessor-controlled prosthetic foot designed to store some of the energy during loading and return it during push-off affects amputee gait. Unilateral transtibial amputees wore the Controlled Energy Storage and Return prosthetic foot (CESR), a conventional foot (CONV), and their previously prescribed foot (PRES) in random order. Three-dimensional gait analysis and net oxygen consumption were collected as participants walked at constant speed. The CESR foot demonstrated increased energy storage during early stance, increased prosthetic foot peak push-off power and work, increased prosthetic limb center of mass (COM) push-off work and decreased intact limb COM collision work compared to CONV and PRES. The biological contribution of the positive COM work for CESR was reduced compared to CONV and PRES. However, the net metabolic cost for CESR did not change compared to CONV and increased compared to PRES, which may partially reflect the greater weight, lack of individualized size and stiffness and relatively less familiarity for CESR and CONV. Controlled energy storage and return enhanced prosthetic push-off, but requires further design modifications to improve amputee walking economy. Published by Elsevier B.V.

  16. Secondary infection of haematoma following closed acromioclavicular joint dislocation

    Science.gov (United States)

    Dupley, Leanne; Berg, Andrew James; Mohil, Randeep

    2016-01-01

    An unusual case of a patient presenting with a large infected haematoma following a traumatic grade II acromioclavicular joint dislocation is reported. Diagnosis of this rare complication, of an otherwise common self-limiting injury, was delayed until 19 days postinjury despite several presentations during this time with worsening swelling and pain. The patient was found to have significant tissue destruction by the time washout was performed and required multiple procedures to treat the infection. This case highlights the need for a high index of suspicion for complications, even following common self-limiting injuries, when patients represent with symptoms that do not fit the usual natural history of the condition, particularly if they have risk factors for bleeding and infection. PMID:26786526

  17. GIANT PROSTHETIC VALVE THROMBUS

    Directory of Open Access Journals (Sweden)

    Prashanth Kumar

    2015-04-01

    Full Text Available Mechanical prosthetic valves are predisposed to bleeding, thrombosis & thromboembolic complications. Overall incidence of thromboembolic complications is 1% per year who are on oral anticoagulants, whereas bleeding complications incidence is 0.5% to 6.6% per year. 1, 2 Minimization of Scylla of thromboembolic & Charybdis of bleeding complication needs a balancing act of optimal antithrombotic therapy. We are reporting a case of middle aged male patient with prosthetic mitral valve presenting in heart failure. Patient had discontinued anticoagulants, as he had subdural hematoma in the past. He presented to our institute with a giant prosthetic valve thrombus.

  18. Dubious space for Artelon joint resurfacing for basal thumb (trapeziometacarpal joint) osteoarthritis. A systematic review.

    Science.gov (United States)

    Smeraglia, Francesco; Mariconda, Massimo; Balato, Giovanni; Di Donato, Sigismondo Luca; Criscuolo, Giovanni; Maffulli, Nicola

    2018-04-06

    Trapeziometacarpal arthritis is a common and disabling condition. There is no evidence in the literature of superiority of one surgical procedure over others. Several prosthetic implants have been introduced to preserve joint mobility. We searched the on Medline (PubMed), Web of Science and Scopus databases using the combined keywords 'artelon', 'thumb', 'carpometacarpal', 'trapeziometacarpal' and 'rhizoarthrosis'; 11 studies were identified. The use of Artelon implant is not recommended because of its high revision rate and worse outcomes compared to conventional techniques. Inert materials subjected to compressive and shearing forces could produce debris and subsequent inflammatory response. There is debate in the published scientific literature regarding the role of preoperative antibiotic profilaxis and post-surgery inflammatory response. Standard techniques such as trapeziectomy alone or combined with interposition or suspensionplasty offer effective treatment for thumb basal joint arthritis. Several prosthetic implants show promising results in terms of pain relief and functional request, but there is a need of long-term randomized controlled trials to demonstrate their equivalence, and eventually superiority, compared to standard techniques.

  19. Mitigated infection in so called aseptic loosening of the total endoprosthesis of the big joints

    OpenAIRE

    Koudela, Karel

    2008-01-01

    The theme of the work is infection in the aseptic loosening of total joint replacement of large joints. Thesis topic is very timely, since inflammatory complications accompanying large joint arthroplasty is one of the causes of failure of total joint replacement and subsequent revision surgery represents a major problem of health, social and economic. PhD thesis summarizes the known aspects of this issue.

  20. Nuclear Medicine in Diagnosis of Prosthetic Valve Endocarditis: An Update

    Science.gov (United States)

    Musso, Maria; Petrosillo, Nicola

    2015-01-01

    Over the past decades cardiovascular disease management has been substantially improved by the increasing introduction of medical devices as prosthetic valves. The yearly rate of infective endocarditis (IE) in patient with a prosthetic valve is approximately 3 cases per 1,000 patients. The fatality rate of prosthetic valve endocarditis (PVE) remains stable over the years, in part due to the aging of the population. The diagnostic value of echocardiography in diagnosis is operator-dependent and its sensitivity can decrease in presence of intracardiac devices and valvular prosthesis. The modified Duke criteria are considered the gold standard for diagnosing IE; their sensibility is 80%, but in clinical practice their diagnostic accuracy in PVE is lower, resulting inconclusively in nearly 30% of cases. In the last years, these new imaging modalities have gained an increasing attention because they make it possible to diagnose an IE earlier than the structural alterations occurring. Several studies have been conducted in order to assess the diagnostic accuracy of various nuclear medicine techniques in diagnosis of PVE. We performed a review of the literature to assess the available evidence on the role of nuclear medicine techniques in the diagnosis of PVE. PMID:25695043

  1. Pregnancy after Prosthetic Aortic Valve Replacement: How Do We Monitor Prosthetic Valvular Function during Pregnancy?

    Directory of Open Access Journals (Sweden)

    Nicole Sahasrabudhe

    2018-01-01

    Full Text Available Background. With modern medicine, many women after structural heart repair are deciding to experience pregnancy. There is a need for further study to identify normal echocardiographic parameters to better assess prosthetic valvular function in pregnancy. In addition, a multidisciplinary approach is essential in managing pregnant patients with complex cardiac conditions. Case. A 22-year-old nulliparous woman with an aortic valve replacement 18 months prior to her pregnancy presented to prenatal care at 20-week gestation. During her prenatal care, serial echocardiography showed a significant increase in the mean gradient across the prosthetic aortic valve. Multidisciplinary management and a serial echocardiography played an integral role in her care that resulted in a successful spontaneous vaginal delivery without complications. Conclusion. Further characterization of the normal echocardiographic parameters in pregnant patients with prosthetic valves is critical to optimize prenatal care for this patient population. This case report is novel in that serial echocardiograms were obtained throughout prenatal care, which showed significant changes across the prosthetic aortic valve. Teaching Points. (1 Further study is needed to identify normal echocardiographic parameters to best assess prosthetic valvular function in pregnancy. (2 Multidisciplinary management is encouraged to optimize prenatal care for women with prosthetic aortic valve replacements.

  2. Mechanical energy profiles of the combined ankle-foot system in normal gait: insights for prosthetic designs.

    Science.gov (United States)

    Takahashi, Kota Z; Stanhope, Steven J

    2013-09-01

    Over the last half-century, the field of prosthetic engineering has continuously evolved with much attention being dedicated to restoring the mechanical energy properties of ankle joint musculatures during gait. However, the contributions of 'distal foot structures' (e.g., foot muscles, plantar soft tissue) have been overlooked. Therefore, the purpose of this study was to quantify the total mechanical energy profiles (e.g., power, work, and work-ratio) of the natural ankle-foot system (NAFS) by combining the contributions of the ankle joint and all distal foot structures during stance in level-ground steady state walking across various speeds (0.4, 0.6, 0.8 and 1.0 statures/s). The results from eleven healthy subjects walking barefoot indicated ankle joint and distal foot structures generally performed opposing roles: the ankle joint performed net positive work that systematically increased its energy generation with faster walking speeds, while the distal foot performed net negative work that systematically increased its energy absorption with faster walking speeds. Accounting for these simultaneous effects, the combined ankle-foot system exhibited increased work-ratios with faster walking. Most notably, the work-ratio was not significantly greater than 1.0 during the normal walking speed of 0.8 statures/s. Therefore, a prosthetic design that strategically exploits passive-dynamic properties (e.g., elastic energy storage and return) has the potential to replicate the mechanical energy profiles of the NAFS during level-ground steady-state walking. Copyright © 2013 Elsevier B.V. All rights reserved.

  3. Percutaneous CT-guided sacroiliac joint sampling for infection: aspiration, biopsy, and technique.

    Science.gov (United States)

    Knipp, David; Simeone, F Joseph; Nelson, Sandra B; Huang, Ambrose J; Chang, Connie Y

    2018-04-01

    To evaluate methods of CT-guided sacroiliac joint sampling in patients with suspected infection. All CT-guided sacroiliac joint sampling procedures for suspected infection were reviewed for sampling type (aspiration, lavage aspiration, biopsy), microbiology results, and clinical and imaging follow-up. The primary gold standard was anatomic pathology. If pathology was not available, then positive blood culture with the same organism as SIJ sampling, imaging and clinical follow-up, or clinical follow-up only were used. Anterior and posterior joint distention was evaluated by MRI within 7 days of the procedure. A total of 34 patients (age 39 ± 20 (range, 6-75) years; 21 F, 13 M) were included. Aspiration samples only were obtained in 13/34 (38%) cases, biopsy samples only in 9/34 (26%) cases, and both samples in 12/34 (35%) cases. There was an overall 54% sensitivity and 86% specificity. For the aspiration samples, sensitivity and specificity were 60 and 81%, respectively, compared to 45 and 90% for the biopsy samples. In cases with both samples, biopsy did not add additional microbial information. Seventeen (17/34, 50%) patients had an MRI. The anterior joint was more distended than the posterior joint in 15/17 (88%) of patients, and this difference was significant (P = 0.0003). All of these 17 patients had an attempted aspiration by a posterior approach; 6/17 (35%) resulted in a successful aspiration. Aspiration of the sacroiliac joint has a higher sensitivity than biopsy and should always be attempted first. MRI may be helpful for procedure planning.

  4. Percutaneous CT-guided sacroiliac joint sampling for infection. Aspiration, biopsy, and technique

    Energy Technology Data Exchange (ETDEWEB)

    Knipp, David; Simeone, F.J.; Huang, Ambrose J.; Chang, Connie Y. [Massachusetts General Hospital, Division of Musculoskeletal Imaging and Intervention, Department of Radiology, Boston, MA (United States); Nelson, Sandra B. [Massachusetts General Hospital, Infectious Disease Unit, Department of Medicine, Boston, MA (United States)

    2018-04-15

    To evaluate methods of CT-guided sacroiliac joint sampling in patients with suspected infection. All CT-guided sacroiliac joint sampling procedures for suspected infection were reviewed for sampling type (aspiration, lavage aspiration, biopsy), microbiology results, and clinical and imaging follow-up. The primary gold standard was anatomic pathology. If pathology was not available, then positive blood culture with the same organism as SIJ sampling, imaging and clinical follow-up, or clinical follow-up only were used. Anterior and posterior joint distention was evaluated by MRI within 7 days of the procedure. A total of 34 patients (age 39 ± 20 (range, 6-75) years; 21 F, 13 M) were included. Aspiration samples only were obtained in 13/34 (38%) cases, biopsy samples only in 9/34 (26%) cases, and both samples in 12/34 (35%) cases. There was an overall 54% sensitivity and 86% specificity. For the aspiration samples, sensitivity and specificity were 60 and 81%, respectively, compared to 45 and 90% for the biopsy samples. In cases with both samples, biopsy did not add additional microbial information. Seventeen (17/34, 50%) patients had an MRI. The anterior joint was more distended than the posterior joint in 15/17 (88%) of patients, and this difference was significant (P = 0.0003). All of these 17 patients had an attempted aspiration by a posterior approach; 6/17 (35%) resulted in a successful aspiration. Aspiration of the sacroiliac joint has a higher sensitivity than biopsy and should always be attempted first. MRI may be helpful for procedure planning. (orig.)

  5. Cervical Facet Joint Infection and Associated Epidural Abscess with Streptococcus intermedius from a Dental Infection Origin A Case Report and Review.

    Science.gov (United States)

    Kaye, Ian David; Protopsaltis, Themistocles S

    2016-09-01

    Pyogenic cervical facet joint infections are rare and such infections from a dental origin are even less common. Of these few cases, none have described infection with Streptococcus intermedius as the pathogen. A 65-year-old orthopaedic surgeon complained of fevers, right-sided radiating neck pain, stiffness, swelling, erythema, and right upper extremity weakness one month after he had broken a crown over his right mandibular premolar, a continued source of pain. Imaging of the cervical spine showed a right C4-C5 facet inflammatory arthropathy and a small epidural abscess that was cultured and initially treated with intravenous antibiotics. The oral maxillofacial surgery team performed an extraction of the infected, symptomatic tooth. For continued right upper extremity weakness, the patient underwent C4-C5 laminoforaminotomy and irrigation and debridement of the right C4-C5 facet joint. After 6 weeks of intravenous antibiotics, the patient's infectious and inflammatory markers had normalized. By 4 months, he had regained full strength at his upper extremity and a painless and full range of motion of his cervical spine.Pyogenic cervical facet joint infection is very rare and potentially dangerous. A high clinical suspicion and appropriate imaging, including magnetic resonance imaging, are important for correct diagnosis. Prompt medical and surgical treatment may avert complications, and although the patient presented made a complete recovery, patients may be left with neurological compromise.

  6. Prevention : T

    NARCIS (Netherlands)

    Boot, Willemijn; Vogely, H. Charles

    2017-01-01

    Joint replacement is a successful surgical procedure that provides pain relief, restores joint function and improves the quality of life of patients. A minority of patients will experience complications like aseptic failure or prosthetic joint infection (PJI; Tande and Patel 2014).

  7. Trichosporon Asahii Infection after Total Knee Arthroplasty: A Case Report and Review of the Literature

    Directory of Open Access Journals (Sweden)

    Qiang Zuo

    2015-01-01

    Full Text Available Reports of fungal infection after total knee arthroplasty are extremely rare. In most reports, the infecting organism is a Candida species. The present report describes a case involving a 73-year-old immunocompetent woman who underwent total knee arthroplasty and presented one month later with signs of prosthetic infection. She underwent joint debridement and the fluid was sent for culture and sensitivity testing. The culture showed growth of Trichosporon asahii. The patient was administered intravenous and intra-articular injections of amphotericin B, followed by antifungal treatment with voriconazole for one year. At 26 months of follow-up, there was no evidence of infection and the patient was ambulating with a walker. To the authors’ knowledge, the present case is the first report of T asahii infection following knee replacement. Early detection, prompt institution of the appropriate antibiotics and regular follow-up are recommended.

  8. Bioactive Coatings for Orthopaedic Implants—Recent Trends in Development of Implant Coatings

    Directory of Open Access Journals (Sweden)

    Bill G. X. Zhang

    2014-07-01

    Full Text Available Joint replacement is a major orthopaedic procedure used to treat joint osteoarthritis. Aseptic loosening and infection are the two most significant causes of prosthetic implant failure. The ideal implant should be able to promote osteointegration, deter bacterial adhesion and minimize prosthetic infection. Recent developments in material science and cell biology have seen the development of new orthopaedic implant coatings to address these issues. Coatings consisting of bioceramics, extracellular matrix proteins, biological peptides or growth factors impart bioactivity and biocompatibility to the metallic surface of conventional orthopaedic prosthesis that promote bone ingrowth and differentiation of stem cells into osteoblasts leading to enhanced osteointegration of the implant. Furthermore, coatings such as silver, nitric oxide, antibiotics, antiseptics and antimicrobial peptides with anti-microbial properties have also been developed, which show promise in reducing bacterial adhesion and prosthetic infections. This review summarizes some of the recent developments in coatings for orthopaedic implants.

  9. Patent urachus with subsequent joint infection in a free-living Grevy's zebra foal.

    Science.gov (United States)

    Ndung'u, Francis K; Ndegwa, Margaret W; deMaar, Thomas W J

    2003-01-01

    A free-living, female Grevy's zebra (Equus grevyi) foal was found lethargic, lame, with swollen joints, pyrexia, and urine dripping from the umbilicus. It died 2 days later despite intensive care. Gross examination revealed patent urachus and suppurative arthritis. Swabs were taken from the joints, the patent urachus, and urine for bacteriology. The dominant isolate was Escherichia coli. The joint infection was probably secondary to septicemia, resulting from the patent urachus. To our knowledge, this is the first report of neonatal patent urachus in a wild equid.

  10. Evaluation of a musculoskeletal model with prosthetic knee through six experimental gait trials.

    Science.gov (United States)

    Kia, Mohammad; Stylianou, Antonis P; Guess, Trent M

    2014-03-01

    Knowledge of the forces acting on musculoskeletal joint tissues during movement benefits tissue engineering, artificial joint replacement, and our understanding of ligament and cartilage injury. Computational models can be used to predict these internal forces, but musculoskeletal models that simultaneously calculate muscle force and the resulting loading on joint structures are rare. This study used publicly available gait, skeletal geometry, and instrumented prosthetic knee loading data [1] to evaluate muscle driven forward dynamics simulations of walking. Inputs to the simulation were measured kinematics and outputs included muscle, ground reaction, ligament, and joint contact forces. A full body musculoskeletal model with subject specific lower extremity geometries was developed in the multibody framework. A compliant contact was defined between the prosthetic femoral component and tibia insert geometries. Ligament structures were modeled with a nonlinear force-strain relationship. The model included 45 muscles on the right lower leg. During forward dynamics simulations a feedback control scheme calculated muscle forces using the error signal between the current muscle lengths and the lengths recorded during inverse kinematics simulations. Predicted tibio-femoral contact force, ground reaction forces, and muscle forces were compared to experimental measurements for six different gait trials using three different gait types (normal, trunk sway, and medial thrust). The mean average deviation (MAD) and root mean square deviation (RMSD) over one gait cycle are reported. The muscle driven forward dynamics simulations were computationally efficient and consistently reproduced the inverse kinematics motion. The forward simulations also predicted total knee contact forces (166Nphysiological motor control patterns during gait. Consequently, the simulations did not accurately predict medial/lateral tibio-femoral force distribution and muscle activation timing. Copyright

  11. Visualization of a prosthetic vascular graft due to platelet contamination during 111Indium-labeled leukocyte scintigraphy

    International Nuclear Information System (INIS)

    Oates, E.; Ramberg, K.

    1988-01-01

    A prosthetic axillo-femoral bypass graft was visualized during 111 In-labeled leukocyte scintigraphy in a patient referred for possible abdominal abscess. The presence of significant cardiac blood-pool activity raised the possibility that this uptake was due to deposition of contaminating labeled platelets rather than labeled leukocytes. An analysis of a small sample of the patient's blood confirmed that the circulating activity was due to labeled platelets. Increased activity along prosthetic vascular grafts in patients undergoing 111 In-labeled leukocyte scintigraphy may be due to adherent platelet, and not indicative of infection

  12. Computer Aided Facial Prosthetics Manufacturing System

    Directory of Open Access Journals (Sweden)

    Peng H.K.

    2016-01-01

    Full Text Available Facial deformities can impose burden to the patient. There are many solutions for facial deformities such as plastic surgery and facial prosthetics. However, current fabrication method of facial prosthetics is high-cost and time consuming. This study aimed to identify a new method to construct a customized facial prosthetic. A 3D scanner, computer software and 3D printer were used in this study. Results showed that the new developed method can be used to produce a customized facial prosthetics. The advantages of the developed method over the conventional process are low cost, reduce waste of material and pollution in order to meet the green concept.

  13. Of bugs and joints: the relationship between infection and joints.

    Science.gov (United States)

    Espinoza, Luis R; García-Valladares, Ignacio

    2013-01-01

    The association between microbes and joints has existed since antiquity, and remains complex. Diagnosis is often times difficult to determine despite highly suspicious clinical characteristics for the presence of an underlying infection. Over the several past decades, considerable advances have occurred in diagnostic methodologies and therapy. However, the morbidity and mortality of septic arthritis remains high. Great advances have occurred in the diagnosis, pathogenesis, and therapeutic management of reactive arthritis, and there is evidence that when the responsible microorganism is Chlamydia trachomathis, complete remission and cure is possible. Emergent infections, especially viral, has been recognized, i.e. HIV, hepatitis C, and most recently Chikengunya virus, and in the case of HIV associated articular manifestations, the introduction of HAART has resulted in a decrease in the incidence and development of newer complications such as the immune reconstitution syndrome. The infectious etiology of rheumatoid arthritis is being strongly considered once again, and the exciting association with periodontal disease is at the forefront of intense research. The gut microbiota is also being investigated and new and most interesting data is being gathered of the potential role of commensal gut organisms and the pathogenesis of rheumatoid arthritis. Copyright © 2011 Elsevier España, S.L. All rights reserved.

  14. The role of osteoblasts in peri-prosthetic osteolysis.

    LENUS (Irish Health Repository)

    O'Neill, S C

    2013-08-01

    Peri-prosthetic osteolysis and subsequent aseptic loosening is the most common reason for revising total hip replacements. Wear particles originating from the prosthetic components interact with multiple cell types in the peri-prosthetic region resulting in an inflammatory process that ultimately leads to peri-prosthetic bone loss. These cells include macrophages, osteoclasts, osteoblasts and fibroblasts. The majority of research in peri-prosthetic osteolysis has concentrated on the role played by osteoclasts and macrophages. The purpose of this review is to assess the role of the osteoblast in peri-prosthetic osteolysis. In peri-prosthetic osteolysis, wear particles may affect osteoblasts and contribute to the osteolytic process by two mechanisms. First, particles and metallic ions have been shown to inhibit the osteoblast in terms of its ability to secrete mineralised bone matrix, by reducing calcium deposition, alkaline phosphatase activity and its ability to proliferate. Secondly, particles and metallic ions have been shown to stimulate osteoblasts to produce pro inflammatory mediators in vitro. In vivo, these mediators have the potential to attract pro-inflammatory cells to the peri-prosthetic area and stimulate osteoclasts to absorb bone. Further research is needed to fully define the role of the osteoblast in peri-prosthetic osteolysis and to explore its potential role as a therapeutic target in this condition.

  15. Prosthesis infections after orthopedic joint replacement: the possible role of bacterial biofilms

    Directory of Open Access Journals (Sweden)

    Zhijun Song

    2013-06-01

    Full Text Available Prosthesis-related infection is a serious complication for patients after orthopedic joint replacement, which is currently difficult to treat with antibiotic therapy. Consequently, in most cases, removal of the infected prosthesis is the only solution to cure the infection. It is, therefore, important to understand the comprehensive interaction between the microbiological situation and the host immune responses that lead to prosthesis infections. Evidence indicates that prosthesis infections are actually biofilm-correlated infections that are highly resistant to antibiotic treatment and the host immune responses. The authors reviewed the related literature in the context of their clinical experience, and discussed the possible etiology and mechanism leading to the infections, especially problems related to bacterial biofilm, and prophylaxis and treatment of infection, including both microbiological and surgical measures. Recent progress in research into bacterial biofilm and possible future treatment options of prosthesis-related infections are discussed.

  16. Local dynamic stability of lower extremity joints in lower limb amputees during slope walking.

    Science.gov (United States)

    Chen, Jin-Ling; Gu, Dong-Yun

    2013-01-01

    Lower limb amputees have a higher fall risk during slope walking compared with non-amputees. However, studies on amputees' slope walking were not well addressed. The aim of this study was to identify the difference of slope walking between amputees and non-amputees. Lyapunov exponents λS was used to estimate the local dynamic stability of 7 transtibial amputees' and 7 controls' lower extremity joint kinematics during uphill and downhill walking. Compared with the controls, amputees exhibited significantly lower λS in hip (P=0.04) and ankle (P=0.01) joints of the sound limb, and hip joints (P=0.01) of the prosthetic limb during uphill walking, while they exhibited significantly lower λS in knee (P=0.02) and ankle (P=0.03) joints of the sound limb, and hip joints (P=0.03) of the prosthetic limb during downhill walking. Compared with amputees level walking, they exhibited significantly lower λS in ankle joints of the sound limb during both uphill (P=0.01) and downhill walking (P=0.01). We hypothesized that the better local dynamic stability of amputees was caused by compensation strategy during slope walking.

  17. Production of radioiodinated prosthetic group for indirect protein labeling

    International Nuclear Information System (INIS)

    Santos, Josefina da Silva

    2001-01-01

    Monoclonal antibodies and their fragments and, more recently, radiolabeled peptides have been extensively studied in order to develop radiopharmaceuticals for diagnostic and therapy in Nuclear Medicine. The radioiodination of proteins can be done by a direct method, with radioiodine being incorporated in to a tyrosine residue of the protein by electrophilic substitution. The main problem in the use of radioiodinated proteins, is that they are often dehalogenated in vivo by the action of specific enzymes, probably because of the structural similarity between iodophenyl groups and thyroid hormones. Several protein radioiodination methods have been developed in order to minimize this in vivo dehalogenation using prosthetic groups for indirect labeling. In this case, the radioiodine is first incorporated in to the prosthetic group that is subsequently attached to a terminal amino group or to a ε-amino group of lysine residue. The aim of this work is to obtain a radioiodinated prosthetic group for indirect labeling of proteins. The prosthetic group selected was the N-succinimidyl-4-radioiodine benzoate (SIB), obtained by the iodination of the p-bromobenzoic acid followed by the reaction with TSTU (0-(N-succinimidyl)-N,N,N',N'-tetramethyl uronium tetrafluoroborate) The results of these studies showed that the p-radio iodobenzoic acid was obtained with a radiochemical purity greater than 92% and a labeling yield of about 65%. Some reaction parameters were studied like temperature, time and Cu Cl mass (cataliser). The SIB was quantitatively obtained from p-radio iodobenzoic acid, using basic medium and after removing the water from the reaction using an nitrogen stream. The kinetic of this reaction is very fast with complete consumption of the p-radioiodebenzoic acid after 5 minutes. The coupling of the SIB prosthetic group to the protein was studied using Human Immunoglobulin (IgG) as a protein model. In a comparative way, the same protein was used on direct labeling

  18. Gradual Hunterian ligation for infected prosthetic bypass.

    Science.gov (United States)

    Egun, A; Slade, D; McCollum, C N

    2000-04-01

    To review gradual snare occlusion for the management of complex or recurrent graft infection. Medical records of patients treated with gradual snare occlusion following graft infection were reviewed for indication for operation, type of bypass and graft material used. In addition, infecting organism, grade of infection (Szilágyi) and outcome were recorded. Four femoropopliteal, two extra-anatomic (axillofemoral) and aortobifemoral bypasses were included in this study. All had chronic infection (Szilágyi grade III) with onset of 4 to 24 months and two of which were recurrent. The causative organisms were coagulase-negative staphylococci, Staphylococcus epidermidis and methicillin-resistant Staphylococcus aureus in three patients, with no organism isolated in the remaining cases. There was no loss of limb following gradual snare occlusion but there was only one death due to aortic stump rupture 2 weeks later. Gradual snare occlusion is an alternative for the management of chronic or recurrent graft infection. Copyright 1999 Harcourt Publishers Ltd.

  19. Differences in the stress distribution in the distal femur between patellofemoral joint replacement and total knee replacement: a finite element study

    Directory of Open Access Journals (Sweden)

    van Jonbergen Hans-Peter W

    2012-06-01

    Full Text Available Abstract Background Patellofemoral joint replacement is a successful treatment option for isolated patellofemoral osteoarthritis. However, results of later conversion to total knee replacement may be compromised by periprosthetic bone loss. Previous clinical studies have demonstrated a decrease in distal femoral bone mineral density after patellofemoral joint replacement. It is unclear whether this is due to periprosthetic stress shielding. The main objective of the current study was to evaluate the stress shielding effect of prosthetic replacement with 2 different patellofemoral prosthetic designs and with a total knee prosthesis. Methods We developed a finite element model of an intact patellofemoral joint, and finite element models of patellofemoral joint replacement with a Journey PFJ prosthesis, a Richards II prosthesis, and a Genesis II total knee prosthesis. For each of these 4 finite element models, the average Von Mises stress in 2 clinically relevant regions of interest were evaluated during a simulated squatting movement until 120 degrees of flexion. Results During deep knee flexion, in the anterior region of interest, the average Von Mises stress with the Journey PFJ design was comparable to the physiological knee, while reduced by almost 25% for both the Richards II design and the Genesis II total knee joint replacement design. The average Von Mises stress in the supracondylar region of interest was similar for both patellofemoral prosthetic designs and the physiological model, with slightly lower stress for the Genesis II design. Conclusions Patellofemoral joint replacement results in periprosthetic stress-shielding, although to a smaller degree than in total knee replacement. Specific patellofemoral prosthetic design properties may result in differences in femoral stress shielding.

  20. Differences in the stress distribution in the distal femur between patellofemoral joint replacement and total knee replacement: a finite element study

    Science.gov (United States)

    2012-01-01

    Background Patellofemoral joint replacement is a successful treatment option for isolated patellofemoral osteoarthritis. However, results of later conversion to total knee replacement may be compromised by periprosthetic bone loss. Previous clinical studies have demonstrated a decrease in distal femoral bone mineral density after patellofemoral joint replacement. It is unclear whether this is due to periprosthetic stress shielding. The main objective of the current study was to evaluate the stress shielding effect of prosthetic replacement with 2 different patellofemoral prosthetic designs and with a total knee prosthesis. Methods We developed a finite element model of an intact patellofemoral joint, and finite element models of patellofemoral joint replacement with a Journey PFJ prosthesis, a Richards II prosthesis, and a Genesis II total knee prosthesis. For each of these 4 finite element models, the average Von Mises stress in 2 clinically relevant regions of interest were evaluated during a simulated squatting movement until 120 degrees of flexion. Results During deep knee flexion, in the anterior region of interest, the average Von Mises stress with the Journey PFJ design was comparable to the physiological knee, while reduced by almost 25% for both the Richards II design and the Genesis II total knee joint replacement design. The average Von Mises stress in the supracondylar region of interest was similar for both patellofemoral prosthetic designs and the physiological model, with slightly lower stress for the Genesis II design. Conclusions Patellofemoral joint replacement results in periprosthetic stress-shielding, although to a smaller degree than in total knee replacement. Specific patellofemoral prosthetic design properties may result in differences in femoral stress shielding. PMID:22704638

  1. Lactococcus garvieae Endocarditis on a Prosthetic Biological Aortic Valve.

    Science.gov (United States)

    Tsur, A; Slutzki, T; Flusser, D

    2015-09-01

    Lactococcus garvieae (LG) endocarditis is a rare disease in humans. There are only about 16 reported cases in the world. We report a 76-year-old male patient with LG endocarditis. In depth interview with the patient revealed that 2 weeks prior to admission, he had eaten sushi containing raw fish. Unlike many of the other infections reported, which were on a native mitral valve, our patient's vegetation was on a prosthetic aortic valve. © 2014 Blackwell Verlag GmbH.

  2. Negative pressure wound therapy for the treatment of infected wounds with exposed knee joint after patellar fracture.

    Science.gov (United States)

    Lee, Sang Yang; Niikura, Takahiro; Miwa, Masahiko; Sakai, Yoshitada; Oe, Keisuke; Fukazawa, Takahiro; Kawakami, Yohei; Kurosaka, Masahiro

    2011-06-14

    Treatment of soft tissue defects with exposed bones and joints, resulting from trauma, infection, and surgical complications, represents a major challenge. The introduction of negative pressure wound therapy has changed many wound management practices. Negative pressure wound therapy has recently been used in the orthopedic field for management of traumatic or open wounds with exposed bone, nerve, tendon, and orthopedic implants. This article describes a case of a patient with a large soft tissue defect and exposed knee joint, in which negative pressure wound therapy markedly improved wound healing. A 50-year-old man presented with an ulceration of his left knee with exposed joint, caused by severe wound infections after open reduction and internal fixation of a patellar fracture. After 20 days of negative pressure wound therapy, a granulated wound bed covered the exposed bones and joint.To our knowledge, this is the first report of negative pressure wound therapy used in a patient with a large soft tissue defect with exposed knee joint. Despite the chronic wound secondary to infection, healing was achieved through the use of the negative pressure wound therapy, thus promoting granulation tissue formation and closing the joint. We suggest negative pressure wound therapy as an alternative option for patients with lower limb wounds containing exposed bones and joints when free flap transfer is contraindicated. Our result added to the growing evidence that negative pressure wound therapy is a useful adjunctive treatment for open wounds around the knee joint. Copyright 2011, SLACK Incorporated.

  3. Pre-prosthetic surgery: Mandible

    Directory of Open Access Journals (Sweden)

    Veeramalai Naidu Devaki

    2012-01-01

    Full Text Available Pre-prosthetic surgery is that part of oral and maxillofacial surgery which restores oral function and facial form. This is concerned with surgical modification of the alveolar process and its surrounding structures to enable the fabrication of a well-fitting, comfortable, and esthetic dental prosthesis. The ultimate goal of pre-prosthetic surgery is to prepare a mouth to receive a dental prosthesis by redesigning and smoothening bony edges.

  4. Guide to prosthetic cardiac valves

    International Nuclear Information System (INIS)

    Morse, D.; Steiner, R.M.; Fernandez, J.

    1985-01-01

    This book contains 10 chapters. Some of the chapter titles are: The development of artificial heart valves: Introduction and historical perspective; The radiology of prosthetic heart valves; The evaluation of patients for prosthetic valve implantation; Pathology of cardiac valve replacement; and Bioengineering of mechanical and biological heart valve substitutes

  5. Analysis of pain and painless symptoms in temporomandibular joints dysfunction in adult patients.

    Science.gov (United States)

    Górecka, Małgorzata; Pihut, Małgorzata; Kulesa-Mrowiecka, Małgorzata

    2017-01-01

    Recent years have shown an increase in the number of patients reporting for treatment of pain due to musculoskeletal joint, associated with temporomandibular joint dysfunction. Therefore, studies were undertaken, aimed at analyzing the symptoms of the dysfunction, because of which patients come to the prosthetic treatment. Aim of the thesis: The aim of the study was a retrospective analysis of symptoms of temporomandibular joint dysfunction reported by patients diagnosed with this problem. The research material was a retrospective medical records of 120 patients, aged 19 to 45 years who have taken prosthetic treatment due to temporomandibular joint dysfunction in the Consulting Room in Prosthetics Department in Kraków, from June 2015 to December 2016. During the test patients, in addition to interviewing a physician, completed a personal survey in their own study. The material has been divided into I group of patients who reported pain form of dysfunction and II group, who had no symptoms of pain within the stomatognatic system. The analysis covered type of symptoms, the share of local factors (para-functions) and systemic, as well as the time a er which the patients reported for the treatment of functional disorders since the appearance of the first symptoms. Analysis of the research material showed that the main reason for reporting patients was pain in one or both temporal joints of significant intensity (5 to 8 in VAS scale,) accompanied by acoustic symptoms. A large group of questioners reported problems with the range of jaw movement and head and face pain, as well as subjective symptoms from the auditory, sight, neck, neck and shoulder areas.

  6. Secure Microprocessor-Controlled Prosthetic Leg for Elderly Amputees: Preliminary Results

    Directory of Open Access Journals (Sweden)

    S. Krut

    2011-01-01

    Full Text Available We introduce a new prosthetic leg design, adapted to elderly trans-femoral amputees. Technical progress in prosthesis design mainly concerns active individuals. An important number of elderly amputees are not very mobile, tire easily, present reduced muscle strength, and have difficulties managing their balance. Therefore, the needs and characteristics of this specific population are very different from those of younger ones and the prosthetic solutions are not adapted. Our artificial knee has been designed to fulfill the specific requirements of this population in terms of capabilities, transfer assistance, security, intuitiveness, simplicity of use, and types of physical activity to be performed. We particularly focused our efforts on ensuring safe and secure stand-to-sit transfers. We developed an approach to control the different states of the prosthetic joint (blocked, free, resistant, associated with different physical activities. Amputee posture and motion are observed through a single multi-axis force sensor embedded in the prosthesis. The patient behaves naturally, while the controller analyses his movements in order to detect his intention to sit down. The detection algorithm is based on a reference pattern, calibrated individually, to which the sensor data are compared, and submitted to a set of tests allowing the discrimination of the intention to sit down from other activities. Preliminary validation of the system has been performed in order to verify the applicability of the prosthesis to different tasks: walking, standing, sitting down, standing up, picking up an object from a chair, slope and stair climbing.

  7. Sensitivity and specificity of simultaneously acquired (dual channel) radiogallium and Tc-99m-HDP in painful hip and knee prosthetic joints

    International Nuclear Information System (INIS)

    Skarzynski, J.J.; Sziklas, J.J.; Rosenberg, R.J.; Rich, D.A.; Spencer, R.P.

    1985-01-01

    Differentiation of prosthetic loosening from infection, by use of sequential bone and radiogallium imaging, has been discussed in the literature. The authors investigated simultaneous (2 channel) imaging of Ga-67 and Tc-99m-HDP in multiviews, in order to assess the parameter of Tc-99m-Ga-67 incongruity. Acquisition of data was carried out 2 days after 5 mCi of Ga-67 citrate IV and 2 hours after 8 mCi of Tc-99m-HDP. Dual data channels were used to insure perfect superimposition of the images and to reduce total imaging time. Normalized bone images were taken, then subtracted from those of Ga-67, by means of progressive weighting factors. A total of 68 studies were carried out on 43 patients. Exams involved both knee and hip prostheses, in population with 63% of the patients over age 60 years. Time from placement of the prosthesis to the dual radionuclide exam was within 2 years in 48% and within 5 years in 78%. Sensitivity was 0.88 and specificity 0.89. Using information on the follow-up dual channel studies, 40/43 cases were correctly identified (93%). Dual channel radionuclide imaging offers a readily available and accurate means of differentiating infection from loosening of hip or knee prostheses

  8. Prosthetic status and prosthetic need among the patients attending various dental institutes of ahmedabad and gandhinagar district, gujarat.

    Science.gov (United States)

    Shah, Vrinda R; Shah, Darshana N; Parmar, Chaitanya H

    2012-09-01

    The oral health being an integral part for the healthy living, necessity of disability limitation and rehabilitation in oral health has taken a paramount role. To assess the prosthetic status and to evaluate the prosthetic needs of the patients attending various institutes of Ahmedabad and Gandhinagar district. A total of 510 (264 males and 246 females) subjects at various dental institutes were examined in the study. A survey proforma was prepared with the help of WHO oral health assessment form (1997). Prosthetic status and prosthetic treatment need was recorded. Out of 510, any type of Edentulousness was 322 (63 %). Among them, 254 (49.8 %) were partially edentulous while 68 (13.3 %) were completely edentulous. Only 69 (13 %) were having any prosthesis in upper arch while only 80 (16 %) were having any prosthesis in lower arch. Need for any type of prosthesis in upper and lower arch was 55 and 60 % in males and females, respectively. In lower social class group need of prosthesis in upper and lower arch was 62 and 63 %, respectively. It was found that prosthetic status and prosthetic treatment need increased with increase in age. Steps should be taken to overcome this disparity and more emphasis should be given to meet the felt need of the people through government and non government organizations to improve the oral health. The unmet prosthetic treatment need should be met to rehabilitate needy people so that their disability may be limited.

  9. A three-dimensional finite element study on the stress distribution pattern of two prosthetic abutments for external hexagon implants.

    Science.gov (United States)

    Moreira, Wagner; Hermann, Caio; Pereira, Jucélio Tomás; Balbinoti, Jean Anacleto; Tiossi, Rodrigo

    2013-10-01

    The purpose of this study was to evaluate the mechanical behavior of two different straight prosthetic abutments (one- and two-piece) for external hex butt-joint connection implants using three-dimensional finite element analysis (3D-FEA). Two 3D-FEA models were designed, one for the two-piece prosthetic abutment (2 mm in height, two-piece mini-conical abutment, Neodent) and another one for the one-piece abutment (2 mm in height, Slim Fit one-piece mini-conical abutment, Neodent), with their corresponding screws and implants (Titamax Ti, 3.75 diameter by 13 mm in length, Neodent). The model simulated the single restoration of a lower premolar using data from a computerized tomography of a mandible. The preload (20 N) after torque application for installation of the abutment and an occlusal loading were simulated. The occlusal load was simulated using average physiological bite force and direction (114.6 N in the axial direction, 17.1 N in the lingual direction and 23.4 N toward the mesial at an angle of 75° to the occlusal plan). The regions with the highest von Mises stress results were at the bottom of the initial two threads of both prosthetic abutments that were tested. The one-piece prosthetic abutment presented a more homogeneous behavior of stress distribution when compared with the two-piece abutment. Under the simulated chewing loads, the von Mises stresses for both tested prosthetic-abutments were within the tensile strength values of the materials analyzed which thus supports the clinical use of both prosthetic abutments.

  10. [Clinical application of continuous douche and vacuum sealing drainage in refractory tissue, bone and joint infections after debridement].

    Science.gov (United States)

    Yang, Ping-lin; He, Xi-jing; Li, Hao-peng; Wang, Guo-yu; Zang, Quan-jin

    2010-01-01

    To explore effect and the application value of continuous douche and vacuum sealing drainage (VSD) in refractory tissue, and joint infections after complete debridement. As retrospective analysis of treatment time and restoration or recurrence, from Jan. 2006 to Dec. 2007, 61 cases of refractory tissue, bone and joint infections underwent continuous douche and VSD combined with the treatment of anti-inflammatory and rehabilitation training after debridement in our hospital. The 61 patients included 39 males and 22 females with age ranging from 10 to 58 years with an average of (35 +/- 12) years, among whom 61 identified to have ankle ulcers combined with infections,open fracture combined with infections, sacrococcygeal pressure ulcers combined with infections, infections after hip replacement, infections after open fracture, and infections after skin avulsion postoperation were 11, 15, 9, 3, 5 and 18 cases respectively. The course was from 2 weeks to 11 months with an average of 4 months. In all 61 patients,the mean healing time was 17, 36, 42, 24, 32, 29 and 28 days in ankle ulcers and infections, tibia and fibula open fracture and infections, femoral shaft fracture and infections, sacrococcygeal pressure ulcers and infections, infections after hip replacement, infections after open fracture, and infections after skin avulsion postoperation respectively. The replacement of VSD was 1, 2-4, 3-5, 1-3, 2-4, 2-3 and 1-3 times in each group respectively. There was no wound recurrence except for 2 cases with recurrent in 61 cases with external fixation nail hole semi-pathological fracture in 1 case of femoral shaft fracture and infection and 1 case of tibia and fibula fracture and infection after follow-up at least one year. Application of continuous douche and VSD can effectively decrease incidence of complications and promote the refractory tissue, bone and joint infections wound growth, healing and considerably shorten the healing time.

  11. Factors Associated with Prosthetic Looseness in Lower Limb Amputees.

    Science.gov (United States)

    Phonghanyudh, Thong; Sutpasanon, Taweesak; Hathaiareerug, Chanasak; Devakula, M L Buddhibongsa; Kumnerddee, Wipoo

    2015-12-01

    To determine the factors associated with prosthetic looseness in lower limb amputees in Sisaket province. The present was a cross-sectional descriptive study. Subjects were lower limb amputees who previously obtained prostheses and required prosthetic replacements at the mobile prosthetic laboratory unit under the Prostheses Foundation of H.R.H. the Princess Mother at Khun Han Hospital, Sisaket province, in February 2013. Data including participant characteristics, prosthetic looseness data, and various variables were collected by direct semi-structured interview. Energy expenditures in physical activities were measured using the Thai version of the short format international physical activity questionnaire. Data between participants with and without prosthetic looseness were compared to determine prosthetic loosening associated factors. Among 101 participants enrolled, 33 (32.7%) had prosthetic looseness with average onset of 1.76 ± 1.67 years. Diabetes mellitus was the only significant factor associated with prosthetic looseness from both univariate and multivariate analyses (HR = 7.05, p = 0.002 and HR = 5.93, p = 0.007 respectively). Among the lower limb amputees in Sisaket province, diabetes mellitus was the only factor associated with prosthetic looseness. Therefore, diabetic screening should be supplemented in lower limb amputee assessment protocol. In addition, we recommend that amputees with diabetes mellitus should receive prosthesis check out at approximately

  12. Can Good Infection Control Be Obtained in One-stage Exchange of the Infected TKA to a Rotating Hinge Design? 10-year Results.

    Science.gov (United States)

    Zahar, Akos; Kendoff, Daniel O; Klatte, Till O; Gehrke, Thorsten A

    2016-01-01

    Prosthetic joint infection (PJI) occurs in 1% to 2% of total knee arthroplasties (TKAs). Although two-stage exchange is the preferred management method of patients with chronic PJI in TKA in North America, one-stage exchange is an alternative treatment method, but long-term studies of this approach have not been conducted. We reviewed our minimum 9-year results of 70 patients who underwent one-stage exchange arthroplasty with a rotating hinge design to determine: (1) What was the proportion of patients free of infection? (2) What was the patient rate of survival free of any reoperation? (3) What were the clinical outcomes as measured by Hospital for Special Surgery scores? (4) What proportion of patients developed radiographic evidence of loosening? All one-stage revision TKAs for infection between January 1 and December 31, 2002, with a minimum 9-year followup (mean, 10 years; range, 9-11 years), in which patients had been seen within the last 1 year, were included in this retrospective review. During that period, 11 patients with infected TKAs were treated with other approaches (including two-stage approaches in eight); the general indication for one-stage revision was the diagnosis of PJI with a known causative organism. Exclusion criteria were culture-negative preoperative aspiration, known allergy to local antibiotics or bone cement, or cases in which radical débridement was impossible as a result of the involvement of important anatomical structures. Eighty-one patients with PJI were seen during this period; 70 underwent one-stage exchange using our strict protocol and were reimplanted with a rotating hinge TKA. Eleven patients (15.7%) were lost to followup. Hospital for Special Surgery scores were recorded and all radiographs were evaluated for prosthetic loosening. Failure was defined as revision surgery for infection or any other cause. Our 10-year infection-free survival was 93% (mean, 4.1; 95% confidence interval [CI], 89%-96%; p exchange techniques for

  13. Optimising the prescription of prosthetic technologies (opptec): Outcome measures for evidence based prosthetic practice and use

    LENUS (Irish Health Repository)

    Ryall, Dr Nicola

    2010-01-01

    This study provided a forum for patients and service providers to voice their opinions in what they believe to be the important predictors and outcomes involved in successful rehabilitation following limb loss. To develop a consensus on the most important outcomes and factors to address for both the lower limb and upper limb prosthetic prescription process, the above data relating to lower limb and upper prosthetics were subsequently used in the next phase of the research involving two Delphi surveys of 23 and 53 experts within the lower limb and upper limb amputation and prosthetic field respectively, including users, service providers and researchers.\\r\

  14. Individual Leg and Joint Work during Sloped Walking for People with a Transtibial Amputation Using Passive and Powered Prostheses

    Directory of Open Access Journals (Sweden)

    Jana R. Jeffers

    2017-12-01

    Full Text Available People with a transtibial amputation using passive-elastic prostheses exhibit reduced prosthetic ankle power and push-off work compared to non-amputees and compensate by increasing their affected leg (AL hip joint work and unaffected leg (UL ankle, knee, and hip joint and leg work during level-ground walking. Use of a powered ankle–foot prosthesis normalizes step-to-step transition work during level-ground walking over a range of speeds for people with a transtibial amputation, but the effects on joint work during level-ground, uphill, and downhill walking have not been assessed. We investigated how use of passive-elastic and powered ankle–foot prostheses affect leg joint biomechanics during level-ground and sloped walking. 10 people with a unilateral transtibial amputation walked at 1.25 m/s on a dual-belt force-measuring treadmill at 0°, ±3°, ±6°, and ±9° using their own passive-elastic and a powered prosthesis (BiOM T2, BionX Medical Technologies, Inc., Bedford, MA, USA while we measured kinematic and kinetic data. We calculated AL and UL prosthetic, ankle, knee, hip, and individual leg positive, negative, and net work. Use of a powered compared to passive-elastic ankle–foot prosthesis resulted in greater AL prosthetic and individual leg net work on uphill and downhill slopes. Over a stride, AL prosthetic positive work was 23–30% greater (p < 0.05 during walking on uphill slopes of +6°, and +9°, prosthetic net work was up to 10 times greater (more positive (p ≤ 0.005 on all uphill and downhill slopes and individual leg net work was 146 and 82% more positive (p < 0.05 at uphill slopes of +6° and +9°, respectively, with use of the powered compared to passive-elastic prosthesis. Greater prosthetic positive and net work through use of a powered ankle–foot prosthesis during uphill and downhill walking improves mechanical work symmetry between the legs, which could decrease metabolic cost and improve functional

  15. CRITERIA FOR THE EVALUATION AND ESTIMATION OF IATROGENIC PROSTHETIC FACTORS – SEMIOLOGY AND SYMPTOMATOLOGY

    Directory of Open Access Journals (Sweden)

    G. LUCA

    2013-12-01

    Full Text Available Introduction: The principles lying at the basis of a balanced dental occlusion cannot be analyzed separately, but only if considering the teeth (and, implicitly, dental occlusion as integrated into the masticatory system, which includes the masticatory muscles, the temporo-mandibu‑ lary joint and the maxillary bones. Scope: The scope of the present study was to correlate and establish the interde‑ pendence between the morpholgically-incorrect prosthetic works and the tissular and functional damages suffered by the neighbouring structures, as a result of some incor‑ rectly-made prosthetic works. Also, the study aims at iden‑ tifying the factors and limits responsible for a prolongued maintenance of such irreversible pathological modificati‑ ons within an asymptomatic zone for the patient. Materials and method: The working hypothesis of the present inves‑ tigation started from the analysis of the various objective signs, versus the morphology of the incorrectly performed prosthetic works. The study, initiated as early as 2009, in a private stomatological clinics (DentEstet, Bucuresti, includes a number of 500 patients (250 women and 250 men, selected among the patients having addressed the stomatological office from various reasons (not always related to the prosthetic pathology of the cases here under investigation. Included in the study have been only the patients with fixed prosthetic works associated with one or several of the previously described objective signs, potentially induced by the iatrogeneicity of the prosthetic works. Results: The pathological effects of the iatrogenic works here under analysis, upon both the antagonistic and prosthetic support teeth, may be clinically identified during a minute examination performed prior to produ‑ cing irreversible final effects (abrasions, fractures, dental mobility, etc.. Such noxious effects of the iatrogenic pros‑ thetic works appear as a false masticatory comfort and as a

  16. Vascular complications of prosthetic inter-vertebral discs

    OpenAIRE

    Daly, Kevin J.; Ross, E. Raymond S.; Norris, Heather; McCollum, Charles N.

    2006-01-01

    Five consecutive cases of prosthetic inter-vertebral disc displacement with severe vascular complications on revisional surgery are described. The objective of this case report is to warn spinal surgeons that major vascular complications are likely with anterior displacement of inter-vertebral discs. We have not been able to find a previous report on vascular complications associated with anterior displacement of prosthetic inter-vertebral discs. In all five patients the prosthetic disc had e...

  17. [An attempt to use ultrasonic technique for confirming the diagnosis, planning and observation of long-term treatment results of painful temporo-mandibular joint dysfunction].

    Science.gov (United States)

    Ey-Chmielewska, H

    1998-01-01

    The author presents an attempt of using ultrasonographic technique in diagnosis, planning and observation of treatment results of temporo-mandibular joint pain dysfunctions. Temporo-mandibular joint pain dysfunctions are interchangeably also called temporo-mandibular joint functional disorders. The assessment of pain symptoms in temporo-mandibular joint dysfunctions pain symptoms is principally based on a subjective estimation by the examining practitioner. There is no univocal definition of the disease or a simple index evidencing important symptoms in decision making. Additionally X-ray technique examinations, being hitherto used, in early stages of the disorder do not allow to diagnose it, and are also burdensome to a patient. The aim of this study was to confirm visibility of anatomical elements of the temporo-mandibular joint in an ultrasound examination, assess the mobility of the articular disc before, during and after prosthetic treatment with and without the use of ultrasound technique, and to determine the period of time necessary to obtain a therapeutic effect. The study material consisted of 180 patients, 128 women and 52 men, aged 20 to 60 years, treated by applying prostheses because of temporo-mandibular joint pain dysfunction, in the Department of Prosthetic Dentistry of the Pomeranian Medical Academy. The patients were divided into 2 groups, control and study group. The control group consisted of 90 patients, 63 women and 27 men. In this group prosthetic treatment planning and observation of results was based on a subjective estimation of the practitioner. The study group here comprised 90 patients, 65 women and 25 men, aged 26 to 60 years. In this group prosthetic treatment planning and observation of treatment results were carried on with the use of ultrasound technique. Data from both groups concerning history, results of examinations carried out by ultrasound technique, and the assessment of ultrasound examination were noted on standard

  18. Advanced Prosthetic Gait Training Tool

    Science.gov (United States)

    2015-12-01

    modules to train individuals to distinguish gait deviations (trunk motion and lower-limb motion). Each of these modules help trainers improve their...AWARD NUMBER: W81XWH-10-1-0870 TITLE: Advanced Prosthetic Gait Training Tool PRINCIPAL INVESTIGATOR: Dr. Karim Abdel-Malek CONTRACTING...study is to produce a computer-based Advanced Prosthetic Gait Training Tool to aid in the training of clinicians at military treatment facilities

  19. Clinical application of 99mTc-HMPAO labeled leucocytes imaging in detecting bone joint infection

    International Nuclear Information System (INIS)

    Li Biao; Barthe, N.; Basse-Cathalinat, B.

    1995-01-01

    99m Tc-MDP scintigraphy and 99m Tc-HMPAO-leucocytes imaging were performed in twenty five patients with clinically suspected bone joint infection. All of the 25 cases were confirmed by surgery, microbiological and histologic examinations. Among them 21 cases were definitively diagnosed as infections, while 3 cases were non-infection. The results of 99m Tc-MDP scintigraphy showed that all of 25 cases demonstrated anomalous accumulation of radioactivity in the clinically suspected infections sites, while in 99m Tc-HMPAO-leucocytes imaging, concentrated radioactivity in proved infectious sites was observed in 19 cases, non-anomalous radioactivity found in 4 cases of non-infectious sites, but there were 2 cases false negative with long term antibiotics treatment, none of the case was false positive. Thereby a sensitivity of the labelled leucocytes imaging of 90.5%, a specificity of 100%, and a accuracy of about 92% were found. Present research work concluded that 99m Tc-HMPAO labelled leucocytes imaging provided a non-invasive, effective, and reliable diagnostic method in detecting patients with clinically suspected bone joint infection and afforded strong evidence for effective therapy

  20. Antibiotic impregnated total femur spacers: a technical tip

    Directory of Open Access Journals (Sweden)

    Colin D. Canham, MD

    2018-03-01

    Full Text Available Simultaneous prosthetic joint infection of ipsilateral hip and knee arthroplasties is often accompanied by significant bone loss and presents a challenging reconstructive problem. Two-stage reconstruction is favored and requires the placement of a total femur spacer, which is not a commercially available device. We describe a surgical technique, reporting on 2 cases in which a customized total femur antibiotic impregnated spacer was created by combining an articulating knee spacer and an articulating hip spacer with a reinforced cement dowel construct connecting the 2 spacers. Custom total femoral spacers are useful in the management of infected femoral megaprostheses and cases with ipsilateral injected hip and knee arthroplasties and severe femoral bone loss. Keywords: total femur spacer, revision arthroplasty, total hip arthroplasty, total knee arthroplasty, prosthetic joint infection

  1. Imaging of bacterial infections of the sacroiliac joint

    International Nuclear Information System (INIS)

    Groves, C.; Cassar-Pullicino, V.

    2004-01-01

    Infection of the sacroiliac joint can be pyogenic or granulomatous and is usually unilateral. There are a number of predisposing conditions including drug abuse and intra articular steroid injection, but in 44% of cases, no definite predisposing factors can be identified. Considerable delay between presentation and diagnosis is recognized. The clinical picture may be non-specific and variable, and clinical suspicion may be low due to the relatively low incidence of the condition. This is compounded by difficulties in clinical examination of the SIJs. The diagnosis is based on a history suggestive of infection, clinical or radiographic localization to the SIJs, and a positive blood culture or joint aspirate. The pathology of pyogenic sacroiliitis is reviewed with respect to the anatomy of the SIJ, and the differential diagnoses considered. The imaging findings, and relative merits of all the modalities are discussed with particular consideration given to changes over the course of the disease. Imaging strategies are evaluated and proposed. As the commonest presenting symptom is low back pain, consideration should be given to the addition of a STIR sequence covering the SIJs on all routine lumbar spine MR examinations. MR imaging is the most sensitive and specific imaging modality, while CT-guided arthrocentesis improves diagnostic confidence. Tc 99 MDP blood pool imaging mirrors the clinical features of resolution, and scintigraphy may be the best method to monitor response to treatment. Targeted antibiotic therapy usually leads to a full recovery. A high incidence of clinical suspicion, with MR imaging at an early stage are the essential prerequisites to an accurate diagnosis of bacterial sacroiliitis. (orig.) [de

  2. Prosthetic Engineering

    Science.gov (United States)

    ... the household and community environments may lead to falls and injuries. This research aims to develop an ankle that can invert and evert and thereby control the center of pressure under the prosthetic foot; enhancing balance and stability of lower limb amputees. Foot-Ankle ...

  3. Elbow joint laxity after experimental radial head excision and lateral collateral ligament rupture

    DEFF Research Database (Denmark)

    Jensen, Steen Lund; Olsen, Bo Sanderhoff; Tyrdal, Stein

    2005-01-01

    The objectives of this experimental study were to investigate the effect of radial head excision and lateral collateral ligament (LCL) division on elbow joint laxity and to determine the efficacy of radial head prosthetic replacement and LCL repair. Valgus, varus, internal rotation, and external...... rotation of the ulna were measured during passive flexion-extension and application of a 0.75-Nm torque in 6 intact cadaveric elbows and after (1) either excision of the radial head or division of the LCL, (2) removal of both constraints, (3) isolated radial head prosthetic replacement, (4) isolated LCL...... normalized varus laxity but resulted in a 2.9 degrees increase in external rotatory laxity. The combined procedures restored laxity completely. The radial head is a constraint to varus and external rotation in the elbow joint, functioning by maintaining tension in the LCL. Still, removal of both constraints...

  4. “In vitro” Implantation Technique Based on 3D Printed Prosthetic Prototypes

    Science.gov (United States)

    Tarnita, D.; Boborelu, C.; Geonea, I.; Malciu, R.; Grigorie, L.; Tarnita, D. N.

    2018-06-01

    In this paper, Rapid Prototyping ZCorp 310 system, based on high-performance composite powder and on resin-high strength infiltration system and three-dimensional printing as a manufacturing method are used to obtain physical prototypes of orthopaedic implants and prototypes of complex functional prosthetic systems directly from the 3D CAD data. These prototypes are useful for in vitro experimental tests and measurements to optimize and obtain final physical prototypes. Using a new elbow prosthesis model prototype obtained by 3D printing, the surgical technique of implantation is established. Surgical implantation was performed on male corpse elbow joint.

  5. Optimization of prosthetic foot stiffness to reduce metabolic cost and intact knee loading during below-knee amputee walking: a theoretical study.

    Science.gov (United States)

    Fey, Nicholas P; Klute, Glenn K; Neptune, Richard R

    2012-11-01

    Unilateral below-knee amputees develop abnormal gait characteristics that include bilateral asymmetries and an elevated metabolic cost relative to non-amputees. In addition, long-term prosthesis use has been linked to an increased prevalence of joint pain and osteoarthritis in the intact leg knee. To improve amputee mobility, prosthetic feet that utilize elastic energy storage and return (ESAR) have been designed, which perform important biomechanical functions such as providing body support and forward propulsion. However, the prescription of appropriate design characteristics (e.g., stiffness) is not well-defined since its influence on foot function and important in vivo biomechanical quantities such as metabolic cost and joint loading remain unclear. The design of feet that improve these quantities could provide considerable advancements in amputee care. Therefore, the purpose of this study was to couple design optimization with dynamic simulations of amputee walking to identify the optimal foot stiffness that minimizes metabolic cost and intact knee joint loading. A musculoskeletal model and distributed stiffness ESAR prosthetic foot model were developed to generate muscle-actuated forward dynamics simulations of amputee walking. Dynamic optimization was used to solve for the optimal muscle excitation patterns and foot stiffness profile that produced simulations that tracked experimental amputee walking data while minimizing metabolic cost and intact leg internal knee contact forces. Muscle and foot function were evaluated by calculating their contributions to the important walking subtasks of body support, forward propulsion and leg swing. The analyses showed that altering a nominal prosthetic foot stiffness distribution by stiffening the toe and mid-foot while making the ankle and heel less stiff improved ESAR foot performance by offloading the intact knee during early to mid-stance of the intact leg and reducing metabolic cost. The optimal design also

  6. An experimental apparatus to simulate body-powered prosthetic usage: Development and preliminary evaluation.

    Science.gov (United States)

    Gao, Fan; Rodriguez, Johanan; Kapp, Susan

    2016-06-01

    Harness fitting in the body-powered prosthesis remains more art than science due to a lack of consistent and quantitative evaluation. The aim of this study was to develop a mechanical, human-body-shaped apparatus to simulate body-powered upper limb prosthetic usage and evaluate its capability of quantitative examination of harness configuration. The apparatus was built upon a torso of a wooden mannequin and integrated major mechanical joints to simulate terminal device operation. Sensors were used to register cable tension, cable excursion, and grip force simultaneously. The apparatus allowed the scapula to move up to 127 mm laterally and the load cell can measure the cable tension up to 445 N. Our preliminary evaluation highlighted the needs and importance of investigating harness configurations in a systematic and controllable manner. The apparatus allows objective, systematic, and quantitative evaluation of effects of realistic harness configurations and will provide insightful and working knowledge on harness fitting in upper limb amputees using body-powered prosthesis. © The International Society for Prosthetics and Orthotics 2015.

  7. Incidence of Infection and Inhospital Mortality in Patients With Chronic Renal Failure After Total Joint Arthroplasty.

    Science.gov (United States)

    Erkocak, Omer F; Yoo, Joanne Y; Restrepo, Camilo; Maltenfort, Mitchell G; Parvizi, Javad

    2016-11-01

    Patients with chronic renal failure (CRF) may require total joint arthroplasty (TJA) to treat degenerative joint disease, fractures, osteonecrosis, or amyloid arthropathy. There have been conflicting results, however, regarding outcomes of TJA in patients with chronic renal disease. The aim of this case-controlled study was to determine the outcome of TJA in patients with CRF, with particular interest in the incidence of infections and inhospital mortality. We queried our electronic database to determine which patients among the 29,389 TJAs performed at our institution between January 2000 and June 2012 had a diagnosis of CRF. A total of 359 CRF patients were identified and matched for procedure, gender, age (±4 years), date of surgery (±2 years), and body mass index (±5 kg/m 2 ) in a 2:1 ratio to 718 control patients. The incidence of infection and inhospital mortality was not significantly different between the nondialysis CRF patients and controls, whereas it was significantly higher in dialysis-dependent end-stage renal failure patients compared to controls. Of the 50 CRF patients receiving hemodialysis, 10 (20%) developed surgical site infection, of which 4 (8%) were periprosthetic joint infection, and 4 (8%) died during hospital stay. The odds ratio for infection in the dialysis group was 7.54 (95% confidence interval: 2.83-20.12) and 10.46 (95% confidence interval: 1.67-65.34) for the inhospital mortality. We conclude that end-stage renal failure patients receiving hemodialysis have higher postoperative infection and inhospital mortality rates after an elective TJA procedure, whereas nondialysis CRF patients have similar outcomes compared with the general TJA population. Copyright © 2016 Elsevier Inc. All rights reserved.

  8. Pseudomonas aeruginosa biofilm formation and slime excretion on antibiotic-loaded bone cement

    NARCIS (Netherlands)

    Neut, D; Hendriks, JGE; van Horn, Jim R.; van der Mei, HC; Busscher, HJ

    Background Infection is an infrequent but serious complication of prosthetic joint surgery. These infections will usually not clear until the implant is removed and re-implantation has a high failure rate, especially when Pseudomonas aeruginosa is involved. Material and methods We examined

  9. Pannus-related prosthetic valve dysfunction. Case report.

    Science.gov (United States)

    Moldovan, Maria-Sînziana; Bedeleanu, Daniela; Kovacs, Emese; Ciumărnean, Lorena; Molnar, Adrian

    2016-01-01

    Pannus-related prosthetic valve dysfunction, a complication of mechanical prosthetic valve replacement, is rare, with a slowly progressive evolution, but it can be acute, severe, requiring surgical reintervention. We present the case of a patient with a mechanical single disc aortic prosthesis, with moderate prosthesis-patient mismatch, minor pannus found on previous ultrasound examinations, who presented to our service with angina pain with a duration of 1 hour, subsequently interpreted as non-ST segment elevation myocardial infarction (NSTEMI) syndrome. Coronarography showed normal epicardial coronary arteries, an ample movement of the prosthetic disc, without evidence of coronary thromboembolism, and Gated Single-Photon Emission Computerized Tomography (SPECT) with Technetium (Tc)-99m detected no perfusion defects. Transthoracic echocardiography (TTE) evidenced a dysfunctional prosthesis due to a subvalvular mass; transesophageal echocardiography (TOE) showed the interference of this mass, with a pannus appearance, with the closure of the prosthetic disc. Under conditions of repeated angina episodes, under anticoagulant treatment, surgery was performed, with the intraoperative confirmation of pannus and its removal. Postoperative evolution was favorable. This case reflects the diagnostic and therapeutic management problems of pannus-related prosthetic valve dysfunction.

  10. Passive prosthetic hands and tools: A literature review.

    Science.gov (United States)

    Maat, Bartjan; Smit, Gerwin; Plettenburg, Dick; Breedveld, Paul

    2018-02-01

    The group of passive prostheses consists of prosthetic hands and prosthetic tools. These can either be static or adjustable. Limited research and development on passive prostheses has been performed although many people use these prosthesis types. Although some publications describe passive prostheses, no recent review of the peer-reviewed literature on passive prostheses is available. Review the peer-reviewed literature on passive prostheses for replacement of the hand. Literature review. Four electronic databases were searched using a Boolean combination of relevant keywords. English-language articles relevant to the objective were selected. In all, 38 papers were included in the review. Publications on passive prosthetic hands describe their users, usage, functionality, and problems in activities of daily living. Publications on prosthetic tools mostly focus on sport, recreation, and vehicle driving. Passive hand prostheses receive little attention in prosthetic research and literature. Yet one out of three people with a limb deficiency uses this type of prosthesis. Literature indicates that passive prostheses can be improved on pulling and grasping functions. In the literature, ambiguous names are used for different types of passive prostheses. This causes confusion. We present a new and clear classification of passive prostheses. Clinical relevance This review provides information on the users of passive prosthetic hands and tools, their usage and the functionality. Passive prostheses receive very little attention and low appreciation in literature. Passive prosthetic hands and tools show to be useful to many unilateral amputees and should receive more attention and higher acceptance.

  11. Validation of the prosthetic esthetic index

    DEFF Research Database (Denmark)

    Özhayat, Esben B; Dannemand, Katrine

    2014-01-01

    OBJECTIVES: In order to diagnose impaired esthetics and evaluate treatments for these, it is crucial to evaluate all aspects of oral and prosthetic esthetics. No professionally administered index currently exists that sufficiently encompasses comprehensive prosthetic esthetics. This study aimed...... to validate a new comprehensive index, the Prosthetic Esthetic Index (PEI), for professional evaluation of esthetics in prosthodontic patients. MATERIAL AND METHODS: The content, criterion, and construct validity; the test-retest, inter-rater, and internal consistency reliability; and the sensitivity...... furthermore distinguish between participants and controls, indicating sufficient sensitivity. CONCLUSION: The PEI is considered a valid and reliable instrument involving sufficient aspects for assessment of the professionally evaluated esthetics in prosthodontic patients. CLINICAL RELEVANCE...

  12. Clinical validation of the avidin/indium-111 biotin approach for imaging infection/inflammation in orthopaedic patients

    International Nuclear Information System (INIS)

    Lazzeri, E.; Molea, N.; Bodei, L.; Bianchi, R.; Manca, M.; Marchetti, S.; Consoli, V.; Chinol, M.; Paganelli, G.; Mariani, G.

    1999-01-01

    We report here the results of a validation study of the avidin/indium-111 biotin approach in patients with skeletal lesions. This study involved 54 patients with orthopaedic conditions: 20 patients with intermediate suspected osteomyelitis of the trunk, 19 patients with infection/inflammation of prosthetic joint replacements, and 15 patients with suspected osteomyelitis of appendicular bones. Avidin (3 mg) was injected as an i.v. bolus, followed 4 h later by 111 In-biotin; imaging was acquired 30 min and 16-18 h after administration of 111 In-biotin. Technetium-99m hexamethylpropylene amine oxime ( 99m Tc-HMPAO)-labelled leucocyte scintigraphy was performed in 39/54 patients. The overall sensitivity of the avidin/ 111 In-biotin scan was 97.7% (versus 88.9% for 99m Tc-HMPAO leucocyte scintigraphy). While the diagnostic performance of avidin/ 111 In-biotin scintigraphy was similar to that of 99m Tc-HMPAO leucocyte scintigraphy in patients with prosthetic joint replacements or osteomyelitis of appendicular bones, the avidin/ 111 In-biotin approach clearly performed better than 99m Tc-HMPAO leucocyte scintigraphy in patients with suspected osteomyelitis of the trunk (100% sensitivity, specificity and accuracy versus 50% sensitivity, 100% specificity and 66.7% accuracy for 99m Tc-HMPAO-leucocyte scintigraphy). These results demonstrate the feasibility of the avidin/ 111 In-biotin approach for imaging sites of infection/inflammation in the clinical setting. Although no systematic advantages of avidin/ 111 In-biotin scintigraphy were found versus 99m Tc-HMPAO leucocyte scintigraphy, the newer scintigraphic method is more practicable and involves lower biological risk for the operators. (orig.)

  13. Multidisciplinary approach for in-deep assessment of joint prosthesis failure.

    Science.gov (United States)

    Tessarolo, F; Caola, I; Piccoli, F; Dorigotti, P; Demattè, E; Molinari, M; Malavolta, M; Barbareschi, M; Caciagli, P; Nollo, G

    2009-01-01

    In spite of advancement in biomaterials and biomechanics, in development of new osteo-integrative materials and coatings, and in macro- micro- component design, a non negligible fraction of the implanted prosthesis fails before the expected lifetime. A prospective observational clinical study has been conducted to define and apply a set of experimental techniques to in-deep assess the failure of joint prosthesis. Microbiological, histological and micro-structural techniques were implemented to specifically address phenomena occurring at the tissue-implant interface. Results obtained from 27 cases of prosthetic joint failure are discussed in terms of sensitivity and specificity. A procedural flow-chart is finally proposed for the assessment of joint prosthesis failure.

  14. Which prosthetic foot to prescribe?

    OpenAIRE

    De Asha, AR; Barnett, CT; Struchkov, V; Buckley, JG

    2017-01-01

    Introduction: \\ud Clinicians typically use findings from cohort studies to objectively inform judgements regarding the potential (dis)advantages of prescribing a new prosthetic device. However, before finalising prescription a clinician will typically ask a patient to 'try out' a change of prosthetic device while the patient is at the clinic. Observed differences in gait when using the new device should be the result of the device’s mechanical function, but could also conceivably be due to pa...

  15. Distal radioulnar joint injuries

    Directory of Open Access Journals (Sweden)

    Binu P Thomas

    2012-01-01

    Full Text Available Distal radioulnar joint is a trochoid joint relatively new in evolution. Along with proximal radioulnar joint , forearm bones and interosseous membrane, it allows pronosupination and load transmission across the wrist. Injuries around distal radioulnar joint are not uncommon, and are usually associated with distal radius fractures,fractures of the ulnar styloid and with the eponymous Galeazzi or Essex_Lopresti fractures. The injury can be purely involving the soft tissue especially the triangular fibrocartilage or the radioulnar ligaments.The patients usually present with ulnar sided wrist pain, features of instability, or restriction of rotation. Difficulty in carrying loads in the hand is a major constraint for these patients. Thorough clinical examination to localize point of tenderness and appropriate provocative tests help in diagnosis. Radiology and MRI are extremely useful, while arthroscopy is the gold standard for evaluation. The treatment protocols are continuously evolving and range from conservative, arthroscopic to open surgical methods. Isolated dislocation are uncommon. Basal fractures of the ulnar styloid tend to make the joint unstable and may require operative intervention. Chronic instability requires reconstruction of the stabilizing ligaments to avoid onset of arthritis. Prosthetic replacement in arthritis is gaining acceptance in the management of arthritis.

  16. [Endoprosthesis Infections - Guidelines for Antibiotic Therapy Common Guidelines of the Czech Society for Orthopaedics and Traumatology and the Society for Infectious Diseases of the Czech Medical Association of J. E. Purkyně].

    Science.gov (United States)

    Musil, D; Balejová, M; Horníková, M; Chrdle, A; Mallátová, N; Nyč, O; Chmelík, V; Gallo, J; Jahoda, D; Stehlík, J

    2017-01-01

    PURPOSE OF THE STUDY This study aims to articulate regional guidelines for curative and suppressive antibiotic therapy of total joint replacement infections. MATERIAL AND METHODS When developing the standard, used as source materials were the published foreign guidelines for antibiotic therapy of prosthetic joint infections, the analysis of resistance of bacterial strains conducted in the Hospital in České Budějovice, a.s. and the assessment of strain resistance for the Czech Republic published by the European Antimicrobial Resistance Surveillance Network (EARS-Net). Considered was also the availability of individual antibiotics in the Czech Republic and restricted prescription according to the Summary of Product Characteristics as specified in the State Institute for Drug Control marketing authorisation. The expert group composed of orthopaedists, microbiologists and infectious disease specialists elaborated the basic antibiotic guideline for choosing an appropriate antibiotic/antifungal drug based on the usual susceptibility, its dose and dosage interval for initial and continuation therapy. The comments of individual specialists were gradually incorporated therein and in case of doubts majority rule was applied. The drafted document was sent for peer reviews to clinical orthopaedic, infectious disease and microbiological centres, whose comments were also incorporated and the finalised document was submitted for evaluation to specialised medical societies. RESULTS The outcome is the submitted guideline for antibiotic curative and suppressive therapy suitable for managing the prosthetic joint infections, which was approved by the committee of the Czech Society for Orthopaedics and Traumatology andthe Society for Infectious Diseases of the Czech Medical Association of J. E. Purkyně. DISCUSION Curative therapy of total joint replacement infections consists primarily in surgical treatment and has to be accompanied by adequate antibiotic therapy administered

  17. Prosthetic rehabilitation of large mid-facial defect with magnet-retained silicone prosthesis

    Directory of Open Access Journals (Sweden)

    Kirti Jajoo Shrivastava

    2015-01-01

    Full Text Available Rehabilitation of maxillofacial defect patients is a challenging task. The most common prosthetic treatment problem with such patients is, getting adequate retention, stability, and support. In cases of large maxillofacial defect, movement of the prosthesis is inevitable. The primary objectives in rehabilitating the maxillofacial defect patients are to restore the function of mastication, deglutition, speech, and to achieve normal orofacial appearance. This clinical report describes maxillofacial prosthetic rehabilitation of large midfacial defect including orbit along with its contents, zygoma and soft tissues including half of the nose, cheeks, upper lip of left side, accompanying postsurgical microstomia and orofacial communication, which resulted from severe fungal infection mucormycosis. The defect in this case was restored with magnet retained two piece maxillofacial prosthesis having hollow acrylic resin framework and an overlying silicone facial prosthesis. The retention of prosthesis was further enhanced with the use of spectacles. This type of combination prosthesis enhanced the cosmesis and functional acceptability of prosthesis.

  18. 10 Kinyanjui-Septic.indd

    African Journals Online (AJOL)

    tract, dental, and urinary tract infections (2). Microorganisms that grow in biofilms typically cause prosthetic joint infections (3). Within biofilms, microorganisms are ... with superior screws, polyethylene insert, ceramic head, and along femoral stem. The lateral wall was augmented with cortical allograft secured with bone.

  19. Bruxism and prosthetic treatment: a critical review.

    Science.gov (United States)

    Johansson, Anders; Omar, Ridwaan; Carlsson, Gunnar E

    2011-07-01

    Based on the findings from available research on bruxism and prosthetic treatment published in the dental literature, an attempt was made to draw conclusions about the existence of a possible relationship between the two, and its clinical relevance. MEDLINE/PubMed searches were conducted using the terms 'bruxism' and 'prosthetic treatment', as well as combinations of these and related terms. The few studies judged to be relevant were critically reviewed, in addition to papers found during an additional manual search of reference lists within selected articles. Bruxism is a common parafunctional habit, occurring both during sleep and wakefulness. Usually it causes few serious effects, but can do so in some patients. The etiology is multifactorial. There is no known treatment to stop bruxism, including prosthetic treatment. The role of bruxism in the process of tooth wear is unclear, but it is not considered a major cause. As informed by the present critical review, the relationship between bruxism and prosthetic treatment is one that relates mainly to the effect of the former on the latter. Bruxism may be included among the risk factors, and is associated with increased mechanical and/or technical complications in prosthodontic rehabilitation, although it seems not to affect implant survival. When prosthetic intervention is indicated in a patient with bruxism, efforts should be made to reduce the effects of likely heavy occlusal loading on all the components that contribute to prosthetic structural integrity. Failure to do so may indicate earlier failure than is the norm. Copyright © 2011 Japan Prosthodontic Society. Published by Elsevier Ltd. All rights reserved.

  20. PERIPROSTHETIC JOINT INFECTION IN PATIENTS WITH RHEUMATIC DISEASES: THE PROBLEMS OF DIAGNOSIS, PREVENTION, AND TREATMENT

    Directory of Open Access Journals (Sweden)

    A. E. Khramov

    2015-01-01

    Full Text Available One of the most menacing complications of large joint total endoprosthesis (TE in patients with rheumatic diseases (RD is the development of periprosthetic infection (PI, progression of which may give rise not only to limb loss, but also death. At the same time, early diagnosis and adequate surgical care make it possible not only to arrest the infectious process, but also to preserve an implanted joint.Objective: to define criteria for the diagnosis, prevention, and treatment of PI after hip and knee joint (HJ and KJ TE in patients with RD.Subjects and methods. In 2009 to 2013, 654 KJ and 549 HJ TE was performed in the V.A. Nasonova Research Instituteof Rheumatology performed KJ (n = 654 and HJ (n = 549 joint ERs.Results and discussion. PI developed in 12 (3.63% and 8 (2.95% patients after KJ and HJ ER, respectively. Early, delayed, and late PI was seen in 11, 6, and 3 patients, respectively. Eleven patients with early PI underwent joint revision/ debridement with preservation of an endoprosthesis and replacement of HJ endoprosthetic inserts and heads. The operations were completed with the collagen hemobiotics being left in the wound and its drainage. Systemic antibiotic therapy was used for 4–6 weeks. No recurrent infection was observed in 9 cases. Two patients underwentresurgery, by setting suction-irrigation systems. Nine patients with delayed or late PI had the following operations: A single-stage revision operation (the endoprosthesis was removed and a new one was implanted was performed in two cases of stable endoprosthetic components and accurately verified low-virulent microorganisms susceptible to certain antibiotics. It was imperative to use cement with an antibiotic, collagen hemobiotics, and systemic antibiotic therapy for 6 weeks. The other 7 patients with unstable endoprosthetic components underwent two-stage revision: Stage 1, endoprosthetic removal and antibiotic-loaded spacer implantation; 6-12 weeks after

  1. In Vivo Assessment of Phage and Linezolid Based Implant Coatings for Treatment of Methicillin Resistant S. aureus (MRSA Mediated Orthopaedic Device Related Infections.

    Directory of Open Access Journals (Sweden)

    Sandeep Kaur

    Full Text Available Staphylococcus comprises up to two-thirds of all pathogens in orthopaedic implant infections with two species respectively Staphylococcus aureus and Staphylococcus epidermidis, being the predominate etiological agents isolated. Further, with the emergence of methicillin-resistant S. aureus (MRSA, treatment of S. aureus implant infections has become more difficult, thus representing a devastating complication. Use of local delivery system consisting of S.aureus specific phage along with linezolid (incorporated in biopolymer allowing gradual release of the two agents at the implant site represents a new, still unexplored treatment option (against orthopaedic implant infections that has been studied in an animal model of prosthetic joint infection. Naked wire, hydroxypropyl methylcellulose (HPMC coated wire and phage and /or linezolid coated K-wire were surgically implanted into the intra-medullary canal of mouse femur bone of respective groups followed by inoculation of S.aureus ATCC 43300(MRSA. Mice implanted with K-wire coated with both the agents i.e phage as well as linezolid (dual coated wires showed maximum reduction in bacterial adherence, associated inflammation of the joint as well as faster resumption of locomotion and motor function of the limb. Also, all the coating treatments showed no emergence of resistant mutants. Use of dual coated implants incorporating lytic phage (capable of self-multiplication as well as linezolid presents an attractive and aggressive early approach in preventing as well as treating implant associated infections caused by methicillin resistant S. aureus strains as assessed in a murine model of experimental joint infection.

  2. Prosthetic management of deciduous teeth

    OpenAIRE

    Bassil, Jean

    2015-01-01

    Projeto de Pós-Graduação/Dissertação apresentado à Universidade Fernando Pessoa como parte dos requisitos para obtenção do grau de Mestre em Medicina Dentária Introduction: Situations of single or multiple edentulous are not an exception during childhood. Prosthetic management is necessary in case of absence of replacing tooth or when its eruption is planned too far in time. Indications of prosthetic rehabilitation for children are multiple and rise from the etiologic factors caus...

  3. 100 top-cited scientific papers in limb prosthetics.

    Science.gov (United States)

    Eshraghi, Arezoo; Osman, Noor Azuan Abu; Gholizadeh, Hossein; Ali, Sadeeq; Shadgan, Babak

    2013-11-17

    Research has tremendously contributed to the developments in both practical and fundamental aspects of limb prosthetics. These advancements are reflected in scientific articles, particularly in the most cited papers. This article aimed to identify the 100 top-cited articles in the field of limb prosthetics and to investigate their main characteristics. Articles related to the field of limb prosthetics and published in the Web of Knowledge database of the Institute for Scientific Information (ISI) from the period of 1980 to 2012. The 100 most cited articles in limb prosthetics were selected based on the citation index report. All types of articles except for proceedings and letters were included in the study. The study design and level of evidence were determined using Sackett's initial rules of evidence. The level of evidence was categorized either as a systematic review or meta-analysis, randomized controlled trial, cohort study, case-control study, case series, expert opinion, or design and development. The top cited articles in prosthetics were published from 1980 to 2012 with a citation range of 11 to 90 times since publication. The mean citation rate was 24.43 (SD 16.7) times. Eighty-four percent of the articles were original publications and were most commonly prospective (76%) and case series studies (67%) that used human subjects (96%) providing level 4 evidence. Among the various fields, rehabilitation (47%), orthopedics (29%), and sport sciences (28%) were the most common fields of study. The study established that studies conducted in North America and were written in English had the highest citations. Top cited articles primarily dealt with lower limb prosthetics, specifically, on transtibial and transradial prosthetic limbs. Majority of the articles were experimental studies.

  4. Responsiveness of the Prosthetic Esthetic Scale

    DEFF Research Database (Denmark)

    Øzhayat, Esben Boeskov

    2017-01-01

    Objectives The aim of the study was to evaluate the responsiveness of the Prosthetic Esthetic Index (PEI) in a population who received prosthetic replacements. Materials and methods Fifty-seven patients who received prosthetic replacement of at least one tooth by means of fixed or removable...... prosthesis were professionally esthetically evaluated using the PEI and the Dental Aesthetic Index (DAI) before and after treatment. The participants further evaluated their oral esthetics using the Oral Health Impact Profile Aesthetic (OHIP-Aes) and Orofacial Esthetic Index (OES). Responsiveness......-Aes and OES scores. The PEI was more consistent in responsiveness than the DAI. Conclusions The PEI shows sufficient responsiveness for use in longitudinal studies and for use as a follow-up measure in clinical practice. Clinical relevance The PEI can in a standardized manner monitor and document esthetic...

  5. Analytical Study of Active Prosthetic Legs

    Science.gov (United States)

    Ono, Kyosuke; Katsumata, Mie

    Walking with prosthesis has not been well analyzed mathematically and it seems that the design of powered prosthesis has been done empirically so far. This paper presents a dynamic simulation of a normal human walking and walking with an active prosthesis. We also studied the two controlling methods of a powered thigh prosthesis based on multi-body simulation of human walking. First we measured the normal human walking gait, then, we showed that a 3-DOF human walking model can walk on level ground by applying tracking control to the measured walking gait within a certain range of tuned walking period. Next, we applied the tracking control and self-excited control to the powered thigh prosthesis and compared the robustness and efficiency of the two control methods by numerical simulation. As a result, we found that the self-excited control can significantly decrease the hip joint torque and specific cost to 1/3 compared with the tracking control. Moreover, the self-excited control is superior to the tracking control because tuning for the walking period is not needed for the active prosthetic leg.

  6. Control method for prosthetic devices

    Science.gov (United States)

    Bozeman, Richard J., Jr. (Inventor)

    1995-01-01

    A control system and method for prosthetic devices is provided. The control system comprises a transducer for receiving movement from a body part for generating a sensing signal associated with that movement. The sensing signal is processed by a linearizer for linearizing the sensing signal to be a linear function of the magnitude of the distance moved by the body part. The linearized sensing signal is normalized to be a function of the entire range of body part movement from the no-shrug position of the moveable body part. The normalized signal is divided into a plurality of discrete command signals. The discrete command signals are used by typical converter devices which are in operational association with the prosthetic device. The converter device uses the discrete command signals for driving the moveable portions of the prosthetic device and its sub-prosthesis. The method for controlling a prosthetic device associated with the present invention comprises the steps of receiving the movement from the body part, generating a sensing signal in association with the movement of the body part, linearizing the sensing signal to be a linear function of the magnitude of the distance moved by the body part, normalizing the linear signal to be a function of the entire range of the body part movement, dividing the normalized signal into a plurality of discrete command signals, and implementing the plurality of discrete command signals for driving the respective moveable prosthesis device and its sub-prosthesis.

  7. Twenty-Year Experience in the Diagnosis and Treatment of Infective Endocarditis.

    Science.gov (United States)

    Abramczuk, Elżbieta; Stępińska, Janina; Hryniewiecki, Tomasz

    2015-01-01

    The aim of this study was to compare the etiology, clinical course, selected diagnostic methods and efficacy of the treatment used in patients with infective endocarditis (IE) in the nineteen eighties and nineties. The study group comprised 300 patients with infective endocarditis hospitalized in the Institute of Cardiology in Warsaw in the following years: from 1982 to 1987 (150 patients: 75 successive patients with IE on the prosthetic valve and 75 successive patients with IE on the native valve), as well as from 1990 to 2003 (150 patients: 75 successive patients with IE on the prosthetic valve and 75 successive patients with IE on the native valve). In the nineties, immunological symptoms, embolism formation and progressive heart failure were diagnosed decidedly more frequently. Early prosthetic valve endocarditis (PVE) (up to 60 days after operation) occurred significantly more frequently in the eighties. The quantity of negative blood cultures in PVE has not decreased, it is still observed in over 20% of cases. For 20 years the etiology of PVE has remained the same, the dominant pathogen remains Staphylococcus. The frequency of PVE caused by Streptococci has markedly reduced. In both the decades analyzed the etiology of native valve endocarditis (NVE) was similar. In the eighties Streptococcus was predominant. In successive years the number of infections caused by Staphylococci was the same as that caused by Streptococci. The incidence of early PVE decreased in the nineties. More patients were treated surgically with lesser peri-operative mortality. A lower incidence of infective endocarditis on prosthetic valves caused by streptococci may signify better prophylaxis against infective endocarditis. Infective endocarditis with sterile blood cultures continues to occur frequently.

  8. Tomographic and echocardiographic diagnosis of mitral prosthetic valve thrombosis

    International Nuclear Information System (INIS)

    Sainz Gonzalez de la Penna, Benito; Ramos Gutierrez, Luis Benito; Gonzalez Artiles, Iovank

    2010-01-01

    Despite the progress achieved in the design of mechanical prosthetic valves, prosthetic valve thrombosis remains a frequent cause of morbidity, usually due to incorrect anticoagulation. A patient was presented with mitral prosthetic thrombosis one year after implantation, who had been diagnosed by transthoracic transesophageal echocardiography imaging and 64-slice computed tomography. Thrombolytic therapy was successful and led to the satisfactory evolution of the patient

  9. Prosthetic Consideration in Implant-supported Prosthesis: A Review of Literature.

    Science.gov (United States)

    Gowd, Manga Snigdha; Shankar, Thatapudi; Ranjan, Rajeev; Singh, Arpita

    2017-06-01

    Modern dentistry has changed tremendously with implant therapy. For the successful implant therapy, making a proper treatment plan considering both surgical and prosthetic part in mind is the key of success. Often practitioners tend to create a treatment plan overlooking the basic principles of prosthetic part. This present review has discussed various prosthetic consideration of implant-supported prosthesis. A step-by-step detailed prosthetic option with their indications has been discussed to help all dental implant practitioners in making of an optimal treatment plan for each case.

  10. Alloplastic temporomandibular joint replacement systems: a systematic review of their history.

    Science.gov (United States)

    De Meurechy, N; Mommaerts, M Y

    2018-06-01

    This systematic review provides an overview of the historical evolution of the prosthetic temporomandibular joint and addresses the challenges and complications faced by engineers and surgeons, in an effort to shed light on why only a few systems remain available. A better understanding of the history of temporomandibular joint prostheses might also provide insights into the origin of the negative public opinion of the prosthesis, which is based on outdated information. A computerized search using the PubMed Central, ScienceDirect, Wiley Online, Ovid, and Cochrane Library databases was performed following the PRISMA guidelines. Out of 7122 articles identified, 41 met the inclusion criteria for this systematic review. Although several historical reviews have been published previously, none has covered such an extensive time period or has described all designs. Furthermore, besides providing a historical overview, this review discusses the rationale behind the evolution in design and biomaterials, which have largely contributed to the outcomes of the prosthetic systems. Copyright © 2018 International Association of Oral and Maxillofacial Surgeons. Published by Elsevier Ltd. All rights reserved.

  11. Risk factors for periprosthetic joint infection following primary total hip or knee arthroplasty: a meta-analysis.

    Science.gov (United States)

    Kong, Lingde; Cao, Junming; Zhang, Yingze; Ding, Wenyuan; Shen, Yong

    2017-06-01

    To identify risk factors for periprosthetic joint infection following primary total joint arthroplasty, a systematic search was performed in Pubmed, Embase and Cochrane library databases. Pooled odds ratios (ORs) or standardised mean differences (SMDs) with 95% confidence intervals (CIs) were calculated. Patient characteristics, surgical-related factors and comorbidities, as potential risk factors, were investigated. The main factors associated with infection after total joint arthroplasty (TJA) were male gender (OR, 1·48; 95% CI, 1.19-1.85), age (SMD, -0·10; 95% CI, -0.17--0.03), obesity (OR, 1·54; 95% CI, 1·25-1·90), alcohol abuse (OR, 1·88; 95% CI, 1·32-2·68), American Society of Anesthesiologists (ASA) scale > 2 (OR, 2·06; 95% CI, 1·77-2·39), operative time (SMD, 0·49; 95% CI, 0·19-0·78), drain usage (OR, 0·36; 95% CI, 0·18-0·74), diabetes mellitus (OR, 1·58; 95% CI, 1·37-1·81), urinary tract infection (OR, 1·53; 95% CI, 1.09-2.16) and rheumatoid arthritis (OR, 1·57; 95% CI, 1·30-1·88). Among these risk factors, ASA score > 2 was a high risk factor, and drain usage was a protective factor. There was positive evidence for some factors that could be used to prevent the onset of infection after TJA. © 2016 Medicalhelplines.com Inc and John Wiley & Sons Ltd.

  12. The role of vision processing in prosthetic vision.

    Science.gov (United States)

    Barnes, Nick; He, Xuming; McCarthy, Chris; Horne, Lachlan; Kim, Junae; Scott, Adele; Lieby, Paulette

    2012-01-01

    Prosthetic vision provides vision which is reduced in resolution and dynamic range compared to normal human vision. This comes about both due to residual damage to the visual system from the condition that caused vision loss, and due to limitations of current technology. However, even with limitations, prosthetic vision may still be able to support functional performance which is sufficient for tasks which are key to restoring independent living and quality of life. Here vision processing can play a key role, ensuring that information which is critical to the performance of key tasks is available within the capability of the available prosthetic vision. In this paper, we frame vision processing for prosthetic vision, highlight some key areas which present problems in terms of quality of life, and present examples where vision processing can help achieve better outcomes.

  13. Antithrombotic Therapy in Patients with Prosthetic Heart Valves

    Directory of Open Access Journals (Sweden)

    Mohamed HA

    2009-01-01

    Full Text Available Patients with mechanical valve prostheses require a lifelong anticoagulant treatment. The combined use of Warfarin and low-dose aspirin appears to reduce the risk of valve thrombosis and systemic embolism at a low risk of bleeding. The management of women with prosthetic heart valves during pregnancy poses a particular challenge, as there are no available controlled clinical trials to provide guidelines for effective antithrombotic therapy. Oral anticoagulants, such as Warfarin, cause foetal embryopathy; unfractionated heparin and low-molecular-weight heparin have been reported to be ineffective in preventing thromboembolic complications.This article discusses the available data and the most recent guidelines in the antithrombotic management of patients with prosthetic valves, and antithrombotic therapy in various clinical situations such as pregnant women with prosthetic heart valves, and patients with prosthetic heart valves undergoing noncardiac surgery.

  14. Clinical validation of the avidin/indium-111 biotin approach for imaging infection/inflammation in orthopaedic patients

    Energy Technology Data Exchange (ETDEWEB)

    Lazzeri, E.; Molea, N.; Bodei, L.; Bianchi, R. [Regional Centre of Nuclear Medicine, University of Pisa, Pisa (Italy); Manca, M.; Marchetti, S.; Consoli, V. [Institute of Orthopedics, University of Pisa, Pisa (Italy); Chinol, M.; Paganelli, G. [Nuclear Medicine Service, European Institute of Oncology, Milan (Italy); Mariani, G. [Nuclear Medicine Service, DIMI, University of Genoa, Genoa (Italy)

    1999-06-01

    We report here the results of a validation study of the avidin/indium-111 biotin approach in patients with skeletal lesions. This study involved 54 patients with orthopaedic conditions: 20 patients with intermediate suspected osteomyelitis of the trunk, 19 patients with infection/inflammation of prosthetic joint replacements, and 15 patients with suspected osteomyelitis of appendicular bones. Avidin (3 mg) was injected as an i.v. bolus, followed 4 h later by {sup 111}In-biotin; imaging was acquired 30 min and 16-18 h after administration of {sup 111}In-biotin. Technetium-99m hexamethylpropylene amine oxime ({sup 99m}Tc-HMPAO)-labelled leucocyte scintigraphy was performed in 39/54 patients. The overall sensitivity of the avidin/{sup 111}In-biotin scan was 97.7% (versus 88.9% for {sup 99m}Tc-HMPAO leucocyte scintigraphy). While the diagnostic performance of avidin/{sup 111}In-biotin scintigraphy was similar to that of {sup 99m}Tc-HMPAO leucocyte scintigraphy in patients with prosthetic joint replacements or osteomyelitis of appendicular bones, the avidin/{sup 111}In-biotin approach clearly performed better than {sup 99m}Tc-HMPAO leucocyte scintigraphy in patients with suspected osteomyelitis of the trunk (100% sensitivity, specificity and accuracy versus 50% sensitivity, 100% specificity and 66.7% accuracy for {sup 99m}Tc-HMPAO-leucocyte scintigraphy). These results demonstrate the feasibility of the avidin/{sup 111}In-biotin approach for imaging sites of infection/inflammation in the clinical setting. Although no systematic advantages of avidin/{sup 111}In-biotin scintigraphy were found versus {sup 99m}Tc-HMPAO leucocyte scintigraphy, the newer scintigraphic method is more practicable and involves lower biological risk for the operators. (orig.) With 3 figs., 2 tabs., 56 refs.

  15. 38 CFR 17.150 - Prosthetic and similar appliances.

    Science.gov (United States)

    2010-07-01

    ... appliances. 17.150 Section 17.150 Pensions, Bonuses, and Veterans' Relief DEPARTMENT OF VETERANS AFFAIRS MEDICAL Prosthetic, Sensory, and Rehabilitative Aids § 17.150 Prosthetic and similar appliances... appliances including invalid lifts and therapeutic and rehabilitative devices, and special clothing made...

  16. Do the radial head prosthesis components fit with the anatomical structures of the proximal radioulnar joint?

    Science.gov (United States)

    Wegmann, Kilian; Hain, Moritz K; Ries, Christian; Neiss, Wolfram F; Müller, Lars P; Burkhart, Klaus J

    2015-09-01

    The fitting accuracy of radial head components has been investigated in the capitulo-radial joint, and reduced contact after prosthetic replacement of the radial head has been observed. The kinematics of the proximal radioulnar joint (PRUJ) are affected by radial head arthroplasty as well, but have not yet been investigated in this regard. The elbow joints of 60 upper extremities of formalin-fixed body donors were disarticulated to obtain a good view of the PRUJ. Each specimen was mounted on the examining table and radial head position in the native PRUJ was assessed in neutral position, full pronation, and full supination. Measurements were repeated after implantation of mono- and bi-polar prostheses. Analysis of the distribution of the joint contacts in the compartments showed significant differences after radial head replacement. In comparison to the native joint, after bipolar and monopolar radial head replacement, the physiological shift of the proximal radius was altered. The physiological shift of the joint contact of the radial head from anterior to posterior during forearm rotation that was found in the native joint in our cadaver model was not observed after prosthetic replacement. With higher conformity and physiological kinematic of radial head prostheses, possibly lower shear forces and lower contact pressures would be generated. The tested radial head prostheses do not replicate the physiological kinematics of the radial head. Further development in the prosthesis design has to be made. The meticulous reconstruction of the annular ligament seems to be of importance to increase joint contact.

  17. Viability of Controlling Prosthetic Hand Utilizing Electroencephalograph (EEG) Dataset Signal

    Science.gov (United States)

    Miskon, Azizi; A/L Thanakodi, Suresh; Raihan Mazlan, Mohd; Mohd Haziq Azhar, Satria; Nooraya Mohd Tawil, Siti

    2016-11-01

    This project presents the development of an artificial hand controlled by Electroencephalograph (EEG) signal datasets for the prosthetic application. The EEG signal datasets were used as to improvise the way to control the prosthetic hand compared to the Electromyograph (EMG). The EMG has disadvantages to a person, who has not used the muscle for a long time and also to person with degenerative issues due to age factor. Thus, the EEG datasets found to be an alternative for EMG. The datasets used in this work were taken from Brain Computer Interface (BCI) Project. The datasets were already classified for open, close and combined movement operations. It served the purpose as an input to control the prosthetic hand by using an Interface system between Microsoft Visual Studio and Arduino. The obtained results reveal the prosthetic hand to be more efficient and faster in response to the EEG datasets with an additional LiPo (Lithium Polymer) battery attached to the prosthetic. Some limitations were also identified in terms of the hand movements, weight of the prosthetic, and the suggestions to improve were concluded in this paper. Overall, the objective of this paper were achieved when the prosthetic hand found to be feasible in operation utilizing the EEG datasets.

  18. Effect of a standardized treatment regime for infection after osteosynthesis.

    Science.gov (United States)

    Hellebrekers, Pien; Leenen, Luke P H; Hoekstra, Meriam; Hietbrink, Falco

    2017-03-09

    Infection after osteosynthesis is an important complication with significant morbidity and even mortality. These infections are often caused by biofilm-producing bacteria. Treatment algorithms dictate an aggressive approach with surgical debridement and antibiotic treatment. The aim of this study is to analyze the effect of such an aggressive standardized treatment regime with implant retention for acute, existing regime consisted of implant retention, thorough surgical debridement, and immediate antibiotic combination therapy with rifampicin. The primary outcome was success. Success was defined as consolidation of the fracture and resolved symptoms of infection. Culture and susceptibility testing were performed to identify bacteria and resistance patterns. Univariate analysis was conducted on patient-related factors in association with primary success and antibiotic resistance. Forty-nine patients were included for analysis. The primary success rate was 63% and overall success rate 88%. Factors negatively associated with primary success were the following: Gustilo classification (P = 0.023), higher number of debridements needed (P = 0.015), inability of primary closure (P = 0.017), and subsequent application of vacuum therapy (P = 0.030). Adherence to the treatment regime was positively related to primary success (P = 0.034). The described treatment protocol results in high success rates, comparable with success rates achieved in staged exchange in prosthetic joint infection treatment.

  19. Pre-prosthetic surgical alterations in maxillectomy to enhance the prosthetic prognoses as part of rehabilitation of oral cancer patient.

    Science.gov (United States)

    El Fattah, H; Zaghloul, A; Pedemonte, E; Escuin, T

    2012-03-01

    After maxillectomy, prosthetic restoration of the resulting defect is an essential step because it signals the beginning of patient's rehabilitation. The obturator used to restore the defect should be comfortable, restore adequate speech, deglutition, mastication, and be cosmetically acceptable, success will depend on the size and location of the defect and the quantity and integrity of the remaining structures, in addition to pre-prosthetic surgical preparation of defect site. Preoperative cooperation between the oncologist surgeon and the maxillofacial surgeon may allow obturation of a resultant defect by preservation of the premaxilla or the tuberosity on the defect side and maintaining the alveolar bone or teeth adjacent to the defect. This study evaluates the importance of pre-prosthetic surgical alterations at the time maxillectomy on the enhancement of the prosthetic prognoses as part of the rehabilitation of oral cancer patient. The study was carried out between 2003- 2008, on 66 cancer patients(41 male-25 female) age ranged from 33 to 72 years, at National Cancer Institute, Cairo University, whom underwent maxillectomy surgery to remove malignant tumor as a part of cancer treatment. Patients were divided in two groups. Group A: Resection of maxilla followed by preprosthetic surgical preparation. Twenty-four cancer patients (13 male - 11 female). Group B: Resection of maxilla without any preprosthetic surgical preparation. Forty-two cancer patients (28 male-14 female). Outcome variables measured included facial contour and aesthetic results, speech understandability, ability to eat solid foods, oronasal separation, socializing outside the home, and return-to-work status. Flap success and donor site morbidity were also studied. To improve the prosthetic restoration of maxillary defect resulting maxillary resection as part treatment of maxillofacial tumor depends on the close cooperation between prosthodontist and surgeon, by combination of pre-prosthetic

  20. Control System for Prosthetic Devices

    Science.gov (United States)

    Bozeman, Richard J. (Inventor)

    1996-01-01

    A control system and method for prosthetic devices is provided. The control system comprises a transducer for receiving movement from a body part for generating a sensing signal associated with that of movement. The sensing signal is processed by a linearizer for linearizing the sensing signal to be a linear function of the magnitude of the distance moved by the body part. The linearized sensing signal is normalized to be a function of the entire range of body part movement from the no-shrug position of the moveable body part through the full-shrg position of the moveable body part. The normalized signal is divided into a plurality of discrete command signals. The discrete command signals are used by typical converter devices which are in operational association with the prosthetic device. The converter device uses the discrete command signals for driving the moveable portions of the prosthetic device and its sub-prosthesis. The method for controlling a prosthetic device associated with the present invention comprises the steps of receiving the movement from the body part, generating a sensing signal in association with the movement of the body part, linearizing the sensing signal to be a linear function of the magnitude of the distance moved by the body part, normalizing the linear signal to be a function of the entire range of the body part movement, dividing the normalized signal into a plurality of discrete command signals, and implementing the plurality of discrete command signals for driving the respective moveable prosthesis device and its sub-prosthesis.

  1. A comparative study of 99Tcm-MDP, 99Tcm(V)-DMSA and 99Tcm-Citrate in diagnosis of bone malignant tumors and bone/joint infections

    International Nuclear Information System (INIS)

    Wu Zhaozhong; Wu Boyi; Lin Wei; Wei Xueli; Wu Hengfu; Fan Ziwen; Ouyang Zhi; Wu Changwei; Yuan Gewen

    2003-01-01

    The purpose of this study was to assess the diagnostic value of scans with 99 Tc m (V)-dimercaptosuccinic acid (DMSA) to localize bone metastases and to evaluate the capability to diagnose bone/joint infections with scans using 99 Tc m -Citrate. Eighteen patients referred to bone metastases and eighteen patients referred to bone and joint infection were studied. In all patients, a bone scan of 99 Tc m -MDP was obtained initially. Subsequently, comparative scans with 99 Tc m (V)-DMSA and 99 Tc m -Citrate were conducted successively. Pathologic finding and/or microbiological finding, X-ray CT and/or MRI, and/or clinical follow-up (until symptoms disappeared) were considered to be proof of the presence of bone metastases and bone/joint infection. All of the eighteen patients with diagnosed bone metastases and of the eighteen patients with diagnosed bone and joint infection had positive 99 Tc m -MDP scintigraphy. The fifteen patients with diagnosed bone metastases and the fifteen patients with diagnosed bone/joint infection had increased 99 Tc m (V) -DMSA accumulation at certain areas matched with those shown in 99 Tc m -MDP scans, and only one patient with diagnosed bone metastases and the fifteen patients with diagnosed bone and joint infection had increased 99 Tc m -Citrate accumulation at certain areas matched with those shown in 99 Tc m -MDP scans. 99 Tc m -MDP scans show 64 bone lesions in the bone metastases while 49 lesions by the 99 Tc m (V)-DMSA scans and only one lesion by the 99 Tc m -Citrate scans respectively. And 99 Tc m -MDP scans show 22 bone lesions in the bone and joint infection while 17 lesions by the 99 Tc m (V)-DMSA imaging and 16 lesions by the 99 Tc m -Citrate imaging respectively. For bone metastases diagnosis, the sensitivity of 99 Tc m (V)-DMSA imaging and 99 Tc m -Citrate imaging were 76.56% and 1.56%, respectively, and the specificity were only 22.73% and 27.27%, respectively. For bone and joint infection diagnosis, the sensitivity of two

  2. Successful thrombolysis of aortic prosthetic valve thrombosis during ...

    African Journals Online (AJOL)

    Successful thrombolysis of aortic prosthetic valve thrombosis during first trimester of pregnancy. A Shukla, AP Raval, R Shah. Abstract. Prosthetic heart valve thrombosis during pregnancy is life-threatening. Standard surgical treatment using cardiopulmonary bypass carries high maternal and fetal complications. Here we ...

  3. Current Role of Imaging in Diagnosing Aortic Graft Infections

    NARCIS (Netherlands)

    Bruggink, Janneke L. M.; Slart, Riemer H. J. A.; Pol, Jillis A.; Reijnen, Michel M. P. J.; Zeebregts, Clark J.

    2011-01-01

    Vascular prosthetic graft infection is a rare but serious complication after aortic graft replacement, with high morbidity and mortality rates. Therefore, adequate diagnostics are needed to detect and treat these infections as early as possible. Several imaging modalities provide different

  4. Preoperative diagnostic for periprosthetic joint infection prior to total knee revision arthroplasty

    Directory of Open Access Journals (Sweden)

    Leif Claassen

    2014-08-01

    Full Text Available Periprosthetic joint infection (PJI after total knee arthroplasty remains a challenging problem. The aim of this study was to evaluate the accuracy of diagnostic knee aspiration and serum inflammatory markers in diagnostic of a PJI after total knee arthroplasty. Within 2011 and 2012, 46 patients received a one- or two-stage revision arthroplasty of the knee joint. These patients received a total number of 77 operations. A preoperative aspiration was performed in each case. We analyzed the microbiological and histological examinations of the samples from the aspiration and from the revision operation and additionally estimated serum inflammatory markers. The diagnostic aspiration had a specificity of 0.87, a sensitivity of 0.39, a positive predictive value of 0.67 and a negative predictive value of 0.68. For C-reactive protein the specificity was 0.61 and the sensitivity was 0.48, the serum white blood cell count had a specificity of 0.98 and a sensitivity of 0.23. Our data queries whether diagnostic joint aspiration or serum inflammatory markers are sufficient to verify or exclude a PJI.

  5. Twenty-Year Experience in the Diagnosis and Treatment of Infective Endocarditis

    Science.gov (United States)

    2015-01-01

    Aims The aim of this study was to compare the etiology, clinical course, selected diagnostic methods and efficacy of the treatment used in patients with infective endocarditis (IE) in the nineteen eighties and nineties. Material and Methods The study group comprised 300 patients with infective endocarditis hospitalized in the Institute of Cardiology in Warsaw in the following years: from 1982 to 1987 (150 patients: 75 successive patients with IE on the prosthetic valve and 75 successive patients with IE on the native valve), as well as from 1990 to 2003 (150 patients: 75 successive patients with IE on the prosthetic valve and 75 successive patients with IE on the native valve). Results In the nineties, immunological symptoms, embolism formation and progressive heart failure were diagnosed decidedly more frequently. Early prosthetic valve endocarditis (PVE) (up to 60 days after operation) occurred significantly more frequently in the eighties. The quantity of negative blood cultures in PVE has not decreased, it is still observed in over 20% of cases. For 20 years the etiology of PVE has remained the same, the dominant pathogen remains Staphylococcus. The frequency of PVE caused by Streptococci has markedly reduced. In both the decades analyzed the etiology of native valve endocarditis (NVE) was similar. In the eighties Streptococcus was predominant. In successive years the number of infections caused by Staphylococci was the same as that caused by Streptococci. Conclusions The incidence of early PVE decreased in the nineties. More patients were treated surgically with lesser peri-operative mortality. A lower incidence of infective endocarditis on prosthetic valves caused by streptococci may signify better prophylaxis against infective endocarditis. Infective endocarditis with sterile blood cultures continues to occur frequently. PMID:26230402

  6. Energy flow analysis of amputee walking shows a proximally-directed transfer of energy in intact limbs, compared to a distally-directed transfer in prosthetic limbs at push-off.

    Science.gov (United States)

    Weinert-Aplin, R A; Howard, D; Twiste, M; Jarvis, H L; Bennett, A N; Baker, R J

    2017-01-01

    Reduced capacity and increased metabolic cost of walking occurs in amputees, despite advances in prosthetic componentry. Joint powers can quantify deficiencies in prosthetic gait, but do not reveal how energy is exchanged between limb segments. This study aimed to quantify these energy exchanges during amputee walking. Optical motion and forceplate data collected during walking at a self-selected speed for cohorts of 10 controls, 10 unilateral trans-tibial, 10 unilateral trans-femoral and 10 bilateral trans-femoral amputees were used to determine the energy exchanges between lower limb segments. At push-off, consistent thigh and shank segment powers were observed between amputee groups (1.12W/kg vs. 1.05W/kg for intact limbs and 0.97W/kg vs. 0.99W/kg for prosthetic limbs), and reduced prosthetic ankle power, particularly in trans-femoral amputees (3.12W/kg vs. 0.87W/kg). Proximally-directed energy exchange was observed in the intact limbs of amputees and controls, while prosthetic limbs displayed distally-directed energy exchanges at the knee and hip. This study used energy flow analysis to show a reversal in the direction in which energy is exchanged between prosthetic limb segments at push-off. This reversal was required to provide sufficient energy to propel the limb segments and is likely a direct result of the lack of push-off power at the prosthetic ankle, particularly in trans-femoral amputees, and leads to their increased metabolic cost of walking. Copyright © 2016 IPEM. Published by Elsevier Ltd. All rights reserved.

  7. Influence of prosthetic radioiodination on the chemical and biological behavior of chemotactic peptides labeled at high specific activity

    International Nuclear Information System (INIS)

    Pozzi, Oscar R.; Sajaroff, Elisa O.; Edreira, Martin M.

    2006-01-01

    The influence of radioiodination made through prosthetic group N-succinimidyl-3-[ 131 I]iodo-benzoate ([ 131 I]SIB) on the behavior of small peptides was investigated using as model the chemotactic hexapeptide Nα-for-Nle-Leu-Phe-Nle-Tyr-Lys. No carrier added labeled peptide was isolated by reverse-phase HPLC (RP-HPLC) with coupling efficiencies up to 59-75%. Biodistribution in normal and infected C57 mice showed mainly a hepatobiliary clearance, a very low thyroid uptake and the highest uptake at the infection site was within 1h of injection. Superoxide production and competitive binding assays studies in human polymorphonuclear leukocytes showed a preserved biological activity and high-affinity specific binding. However, the results indicated that the changes observed in the receptor-binding properties with an IC 50 almost twice than the unlabeled peptide and the increasing in the hepatobiliary excretion could be the consequence of the increased lipophicity observed due to the presence of the prosthetic group together with a strong influence of the radioisotope per se

  8. Influence of prosthetic radioiodination on the chemical and biological behavior of chemotactic peptides labeled at high specific activity

    Energy Technology Data Exchange (ETDEWEB)

    Pozzi, Oscar R. [National Atomic Energy Commission, Ezeiza Atomic Centre, Buenos Aires (Argentina)]. E-mail: oscar.pozzi@duke.edu; Sajaroff, Elisa O. [National Atomic Energy Commission, Ezeiza Atomic Centre, Buenos Aires (Argentina); Edreira, Martin M. [National Atomic Energy Commission, Ezeiza Atomic Centre, Buenos Aires (Argentina)

    2006-06-15

    The influence of radioiodination made through prosthetic group N-succinimidyl-3-[{sup 131}I]iodo-benzoate ([{sup 131}I]SIB) on the behavior of small peptides was investigated using as model the chemotactic hexapeptide N{alpha}-for-Nle-Leu-Phe-Nle-Tyr-Lys. No carrier added labeled peptide was isolated by reverse-phase HPLC (RP-HPLC) with coupling efficiencies up to 59-75%. Biodistribution in normal and infected C57 mice showed mainly a hepatobiliary clearance, a very low thyroid uptake and the highest uptake at the infection site was within 1h of injection. Superoxide production and competitive binding assays studies in human polymorphonuclear leukocytes showed a preserved biological activity and high-affinity specific binding. However, the results indicated that the changes observed in the receptor-binding properties with an IC{sub 50} almost twice than the unlabeled peptide and the increasing in the hepatobiliary excretion could be the consequence of the increased lipophicity observed due to the presence of the prosthetic group together with a strong influence of the radioisotope per se.

  9. 21 CFR 890.3025 - Prosthetic and orthotic accessory.

    Science.gov (United States)

    2010-04-01

    ... (CONTINUED) MEDICAL DEVICES PHYSICAL MEDICINE DEVICES Physical Medicine Prosthetic Devices § 890.3025... intended for medical purposes to support, protect, or aid in the use of a cast, orthosis (brace), or prosthesis. Examples of prosthetic and orthotic accessories include the following: A pelvic support band and...

  10. Undergraduate prosthetics and orthotics teaching methods: A baseline for international comparison.

    Science.gov (United States)

    Aminian, Gholamreza; O'Toole, John M; Mehraban, Afsoon Hassani

    2015-08-01

    Education of Prosthetics and Orthotics is a relatively recent professional program. While there has been some work on various teaching methods and strategies in international medical education, limited publication exists within prosthetics and orthotics. To identify the teaching and learning methods that are used in Bachelor-level prosthetics and orthotics programs that are given highest priority by expert prosthetics and orthotics instructors from regions enjoying a range of economic development. Mixed method. The study partly documented by this article utilized a mixed method approach (qualitative and quantitative methods) within which each phase provided data for other phases. It began with analysis of prosthetics and orthotics curricula documents, which was followed by a broad survey of instructors in this field and then a modified Delphi process. The expert instructors who participated in this study gave high priority to student-centered, small group methods that encourage critical thinking and may lead to lifelong learning. Instructors from more developed nations placed higher priority on student's independent acquisition of prosthetics and orthotics knowledge, particularly in clinical training. Application of student-centered approaches to prosthetics and orthotics programs may be preferred by many experts, but there appeared to be regional differences in the priority given to different teaching methods. The results of this study identify the methods of teaching that are preferred by expert prosthetics and orthotics instructors from a variety of regions. This treatment of current instructional techniques may inform instructor choice of teaching methods that impact the quality of education and improve the professional skills of students. © The International Society for Prosthetics and Orthotics 2014.

  11. Rehabilitation and Prosthetic Services

    Science.gov (United States)

    ... Review Resources AT Education Blind Rehab Chiropractic Service Polytrauma/TBI Prosthetics & Sensory Aids Recreation Therapy More Health ... Military Sexual Trauma PTSD Research (MIRECC) Military Exposures Polytrauma Rehabilitation Spinal Cord Injury Telehealth Womens Health Issues ...

  12. Successful Management of Prosthetic Valve Brucella Endocarditis with Antibiotherapy Alone

    Directory of Open Access Journals (Sweden)

    José Pedro Fonseca

    2018-01-01

    Full Text Available Objectives: To report a case of mechanical aortic prosthesis Brucella endocarditis successfully treated with antibiotics alone. Materials and methods: We describe a clinical case and present a review of the literature. Results: A 60-year-old female farmer with a mechanical aortic prosthetic valve presented with low back pain and fever. She was diagnosed with prosthetic valve Brucella mellitensis endocarditis and was cured with antibiotic therapy alone. Few cases of successfully treated prosthetic valve Brucella endocarditis without surgery have been reported. Conclusion: Prosthetic valve Brucella endocarditis usually requires surgical valve replacement. However, selected patients may be successfully treated with antibiotic therapy alone.

  13. Provision of Prosthetic Services Following Lower Limb Amputation in Malaysia

    Science.gov (United States)

    Arifin, Nooranida; Hasbollah, Hasif Rafidee; Hanafi, Muhammad Hafiz; Ibrahim, Al Hafiz; Rahman, Wan Afezah Wan Abdul; Aziz, Roslizawati Che

    2017-01-01

    The incidence of lower limb amputation is high across the globe and continues to be a major threat to morbidity and mortality. Consequently, the provision of high quality and effective prosthetics services have been known as an essential component for a successful rehabilitation outcome. In Malaysia, amputation prevalence has been increasing in which several main components of service delivering aspects (such as service intervention, prosthetic personnel) should be anticipated to accommodate for the increasing demand. This article highlights the hurdles experienced in providing prosthetic services in Malaysia from multiple aspects such as financial burden to acquire the prosthesis and lack of expertise to produce quality prosthesis. This paramount issues consequently justify for the urgency to carry out national level survey on the current statistics of lower limb amputation and to ascertain the available workforce to provide a quality prosthetics services. Only with accurate and current information from the national survey, strategies and policies aimed at enhancing the outcome from prosthetics services can be achieved. PMID:29386978

  14. Periprosthetic joint infections: a clinical practice algorithm.

    Science.gov (United States)

    Volpe, Luigi; Indelli, Pier Francesco; Latella, Leonardo; Poli, Paolo; Yakupoglu, Jale; Marcucci, Massimiliano

    2014-01-01

    periprosthetic joint infection (PJI) accounts for 25% of failed total knee arthroplasties (TKAs) and 15% of failed total hip arthroplasties (THAs). The purpose of the present study was to design a multidisciplinary diagnostic algorithm to detect a PJI as cause of a painful TKA or THA. from April 2010 to October 2012, 111 patients with suspected PJI were evaluated. The study group comprised 75 females and 36 males with an average age of 71 years (range, 48 to 94 years). Eighty-four patients had a painful THA, while 27 reported a painful TKA. The stepwise diagnostic algorithm, applied in all the patients, included: measurement of serum C-reactive protein (CRP) and erythrocyte sedimentation rate (ESR) levels; imaging studies, including standard radiological examination, standard technetium-99m-methylene diphosphonate (MDP) bone scan (if positive, confirmation by LeukoScan was obtained); and joint aspiration with analysis of synovial fluid. following application of the stepwise diagnostic algorithm, 24 out of our 111 screened patients were classified as having a suspected PJI (21.7%). CRP and ESR levels were negative in 84 and positive in 17 cases; 93.7% of the patients had a positive technetium-labeled bone scan, and 23% a positive LeukoScan. Preoperative synovial fluid analysis was positive in 13.5%; analysis of synovial fluid obtained by preoperative aspiration showed a leucocyte count of > 3000 cells μ/l in 52% of the patients. the present study showed that the diagnosis of PJI requires the application of a multimodal diagnostic protocol in order to avoid complications related to surgical revision of a misdiagnosed "silent" PJI. Level IV, therapeutic case series.

  15. Prosthetic Status and Prosthetic Need Among the Patients Attending Various Dental Institutes of Ahmedabad and Gandhinagar District, Gujarat

    OpenAIRE

    Shah, Vrinda R.; Shah, Darshana N.; Parmar, Chaitanya H.

    2012-01-01

    The oral health being an integral part for the healthy living, necessity of disability limitation and rehabilitation in oral health has taken a paramount role. To assess the prosthetic status and to evaluate the prosthetic needs of the patients attending various institutes of Ahmedabad and Gandhinagar district. A total of 510 (264 males and 246 females) subjects at various dental institutes were examined in the study. A survey proforma was prepared with the help of WHO oral health assessment ...

  16. Interleukin-6 in serum and in synovial fluid enhances the differentiation between periprosthetic joint infection and aseptic loosening.

    Directory of Open Access Journals (Sweden)

    Thomas M Randau

    Full Text Available The preoperative differentiation between septic and aseptic loosening after total hip or knee arthroplasty is essential for successful therapy and relies in part on biomarkers. The objective of this study was to assess synovial and serum levels of inflammatory proteins as diagnostic tool for periprosthetic joint infection and compare their accuracy with standard tests. 120 patients presenting with a painful knee or hip endoprosthesis for surgical revision were included in this prospective trial. Blood samples and samples of intraoperatively acquired joint fluid aspirate were collected. White blood cell count, C-reactive protein, procalcitonin and interleukin-6 were determined. The joint aspirate was analyzed for total leukocyte count and IL-6. The definite diagnosis of PJI was determined on the basis of purulent synovial fluid, histopathology and microbiology. IL-6 in serum showed significantly higher values in the PJI group as compared to aseptic loosening and control, with specificity at 58.3% and a sensitivity of 79.5% at a cut-off value of 2.6 pg/ml. With a cut-off >6.6 pg/ml, the specificity increased to 88.3%. IL-6 in joint aspirate had, at a cut-off of >2100 pg/ml, a specificity of 85.7% and sensitivity of 59.4%. At levels >9000 pg/ml, specificity was almost at 100% with sensitivity just below 50%, so PJI could be considered proven with IL-6 levels above this threshold. Our data supports the published results on IL-6 as a biomarker in PJI. In our large prospective cohort of revision arthroplasty patients, the use of IL-6 in synovial fluid appears to be a more accurate marker than either the white blood cell count or the C-reactive protein level in serum for the detection of periprosthetic joint infection. On the basis of the results we recommend the use of the synovial fluid biomarker IL-6 for the diagnosis of periprosthetic joint infection following total hip and knee arthroplasty.

  17. Interleukin-6 in serum and in synovial fluid enhances the differentiation between periprosthetic joint infection and aseptic loosening.

    Science.gov (United States)

    Randau, Thomas M; Friedrich, Max J; Wimmer, Matthias D; Reichert, Ben; Kuberra, Dominik; Stoffel-Wagner, Birgit; Limmer, Andreas; Wirtz, Dieter C; Gravius, Sascha

    2014-01-01

    The preoperative differentiation between septic and aseptic loosening after total hip or knee arthroplasty is essential for successful therapy and relies in part on biomarkers. The objective of this study was to assess synovial and serum levels of inflammatory proteins as diagnostic tool for periprosthetic joint infection and compare their accuracy with standard tests. 120 patients presenting with a painful knee or hip endoprosthesis for surgical revision were included in this prospective trial. Blood samples and samples of intraoperatively acquired joint fluid aspirate were collected. White blood cell count, C-reactive protein, procalcitonin and interleukin-6 were determined. The joint aspirate was analyzed for total leukocyte count and IL-6. The definite diagnosis of PJI was determined on the basis of purulent synovial fluid, histopathology and microbiology. IL-6 in serum showed significantly higher values in the PJI group as compared to aseptic loosening and control, with specificity at 58.3% and a sensitivity of 79.5% at a cut-off value of 2.6 pg/ml. With a cut-off >6.6 pg/ml, the specificity increased to 88.3%. IL-6 in joint aspirate had, at a cut-off of >2100 pg/ml, a specificity of 85.7% and sensitivity of 59.4%. At levels >9000 pg/ml, specificity was almost at 100% with sensitivity just below 50%, so PJI could be considered proven with IL-6 levels above this threshold. Our data supports the published results on IL-6 as a biomarker in PJI. In our large prospective cohort of revision arthroplasty patients, the use of IL-6 in synovial fluid appears to be a more accurate marker than either the white blood cell count or the C-reactive protein level in serum for the detection of periprosthetic joint infection. On the basis of the results we recommend the use of the synovial fluid biomarker IL-6 for the diagnosis of periprosthetic joint infection following total hip and knee arthroplasty.

  18. LEAK study : design of a nationwide randomised controlled trial to find the best way to treat wound leakage after primary hip and knee arthroplasty

    NARCIS (Netherlands)

    Löwik, Claudia A M; Wagenaar, Frank-Christiaan; van der Weegen, Walter; Poolman, Rudolf W; Nelissen, Rob G H H; Bulstra, Sjoerd K; Pronk, Yvette; Vermeulen, Karin M; Wouthuyzen-Bakker, Marjan; van den Akker-Scheek, Inge; Stevens, Martin; Jutte, Paul C

    2017-01-01

    INTRODUCTION: Total hip arthroplasty (THA) and total knee arthroplasty (TKA) are highly successful treatment modalities for advanced osteoarthritis. However, prolonged wound leakage after arthroplasty is linked to prosthetic joint infection (PJI), which is a potentially devastating complication. On

  19. Adaptive sports technology and biomechanics: prosthetics.

    Science.gov (United States)

    De Luigi, Arthur Jason; Cooper, Rory A

    2014-08-01

    With the technologic advances in medicine and an emphasis on maintaining physical fitness, the population of athletes with impairments is growing. It is incumbent upon health care practitioners to make every effort to inform these individuals of growing and diverse opportunities and to encourage safe exercise and athletic participation through counseling and education. Given the opportunities for participation in sports for persons with a limb deficiency, the demand for new, innovative prosthetic designs is challenging the clinical and technical expertise of the physician and prosthetist. When generating a prosthetic prescription, physicians and prosthetists should consider the needs and preferences of the athlete with limb deficiency, as well as the functional demands of the chosen sporting activity. The intent of this article is to provide information regarding the current advancements in the adaptive sports technology and biomechanics in the field of prosthetics, and to assist clinicians and their patients in facilitating participation in sporting activities. Copyright © 2014 American Academy of Physical Medicine and Rehabilitation. Published by Elsevier Inc. All rights reserved.

  20. QT Prolongation Complicated with Torsades de Pointes in Prosthetic Mitral Valve Endocarditis: A Case Report

    Directory of Open Access Journals (Sweden)

    A. Tounsi

    2012-01-01

    Full Text Available We present the case of a 49-year-old male patient with prosthetic mitral valve endocarditis associated with QT prolongation and torsades de pointes. He was asymptomatic until the end of January 2012, when he was admitted to our hospital emergency unit because of syncope, fever, and suspicion of endocarditis. Cardiologic evaluation was requested and the transthoracic (TTE and transesophageal (TEE echocardiograms revealed vegetations on the prosthetic mitral valve. All cultures were positive for methicillin-sensitive Staphylococcus aureus. The corrected QT (QTc interval was markedly prolonged upon admission (QTc 540 ms. He experienced torsades de pointes (TdP several times and he was recovered after bystander cardiopulmonary resuscitation. The clinical course and the long QTc interval with deep inverted T wave were completely normalized 4 weeks after. He continued on triple antibiotic therapy for 45 days with a good revolution. The clinical features and the possible mechanisms of QT prolongation (inflammation, infection of this patient are discussed.

  1. [Custom-made implant for complex facial reconstruction: A case of total replacement of temporo-mandibular joint, zygomatic arch and malar bone].

    Science.gov (United States)

    Guillier, D; Moris, V; See, L-A; Girodon, M; Wajszczak, B-L; Zwetyenga, N

    2017-02-01

    Total prosthetic replacement of the temporo-mandibular joint (TMJ) has become a common procedure, but it is usually limited to the TMJ itself. We report about one case of complex prosthetic joint reconstruction extending to the neighbouring bony structures. A 57-year-old patient, operated several times for a cranio-facial fibrous dysplasia, presented with a recurring TMJ ankylosis and a complexe latero-facial bone loss on the right side. We performed a reconstruction procedure including the TMJ, the zygomatic arch and the malar bone by mean of custom made composite prosthesis (chrome-cobalt-molybdenum-titanium and polyethylene). Five years postoperatively, mouth opening, nutrition, pain and oral hygiene were significantly improved. Nowadays technical possibilities allow for complex facial alloplastic reconstructions with good medium term results. Copyright © 2017 Elsevier Masson SAS. All rights reserved.

  2. Prosthetic implant treatment of the edentulous maxilla with overdenture.

    Science.gov (United States)

    Inversini, M

    2006-10-01

    The literature concerning the success of prosthetic implant treatment with maxillary overdenture is reviewed, and variables affecting treatment from the implant and prosthetic standpoint are analysed. Guidelines for the fabrication of maxillary overimplants comparable to those for mandibular overimplants are still lacking, as are evidence-based prosthetic design concepts. Individual methods and techniques have been described, but evaluation standards for the outcome of maxillary prosthetic-implant treatment are lacking or individually interpreted. The biomechanics involved in the proposed system are described, together with the advantages of telescopic crowns for the retention of removable partial prosthesis supported by maxillary implants. The positive influence, in terms of long-term prognosis, of the perio-protective design of removable partial prostheses supported by maxillary overimplants is also discussed. The proposed system not only provides stability, support and retention for removable partial prostheses supported by maxillary implants, but also enables implant survival rates to be improved, both for biomechanical reasons and due to improved oral hygiene. The simplification of fabrication procedures, repair, rebasing and re-operating also reduce the cost of follow-up and improve the cost/benefit ratio. However, additional studies are needed to clarify the number and most appropriate distribution of implants, as well as the most favourable prosthetic designs for maxillary overimplants.

  3. Surgical-prosthetic treatment of large mandibular cysts

    Directory of Open Access Journals (Sweden)

    Džambas Ljubiša D.

    2003-01-01

    Full Text Available This paper presents a combined surgical-prosthetic procedure of reconstructing mandibular bone defect in a 53 year old patient, following enucleation of a mandibular cyst (Cystectomy Partsch II. After a thorough diagnostic evaluation, a surgical procedure was planned with the particular attention to the nature of the disease, patient’s condition, size and extension of the cyst, tissue loss, and the possibilities of prosthetic management of a mandibular bone defect with partial postresection dental prosthesis. It is of great importance to point to the significance of teamwork of a maxillofacial surgeon and a specialist in prosthodontics. This kind of cooperation provided very effective and less risky soft tissue, as well as bone tissue regeneration (osteogenesis. The patient’s recovery was fast, and he could return to his daily activities and work without significant changes regarding quality of life after surgery and prosthetic treatment.

  4. Prosthetics in Paediatric Dentistry

    Directory of Open Access Journals (Sweden)

    Vulićević Zoran

    2017-07-01

    Full Text Available Premature loss of teeth in children may lead to both functional and esthetic problems. Missing teeth in both anterior and posterior regions may cause malfunctions in mastication and proper pronunciation. If the missing teeth are not replaced, further complications may occur, including adjacent tooth migration, loss of alveolar bone, and irregular occlusion. Considering the sensitive nature of children, loss of teeth may cause the development of insecurities and low self esteem problems. Due to dynamic nature of growth in children and adolescents, prosthetic appliances must not hinder development of orofacial system, and must meet adequate esthetic and functional standards. Dental prosthetic appliances in paediatrics must be planned with respect to the special conditions that led to tooth loss or damage. Multi-disciplinary approach is needed, under constant supervision of paediatric dentist and orthodontist, as well as regular checkups with clinical and radiographical examinations.

  5. Custom-made laser-welded titanium implant prosthetic abutment.

    Science.gov (United States)

    Iglesia-Puig, Miguel A

    2005-10-01

    A technique to create an individually modified implant prosthetic abutment is described. An overcasting is waxed onto a machined titanium abutment, cast in titanium, and joined to it with laser welding. With the proposed technique, a custom-made titanium implant prosthetic abutment is created with adequate volume and contour of metal to support a screw-retained, metal-ceramic implant-supported crown.

  6. Prosthetic Rehabilitation in Children: An Alternative Clinical Technique

    Directory of Open Access Journals (Sweden)

    Nádia Carolina Teixeira Marques

    2013-01-01

    Full Text Available Complete and partial removable dentures have been used successfully in numerous patients with oligodontia and/or anodontia. However, there is little information in the literature regarding the principles and guidelines to prosthetic rehabilitation for growing children. This case report describes the management of a young child with oligodontia as well as the treatment planning and the prosthetic rehabilitation technique.

  7. Imaging of hip joint arthroplasty; Bildgebung bei Hueftgelenkendoprothesen

    Energy Technology Data Exchange (ETDEWEB)

    Mayerhoefer, M.E.; Fruehwald-Pallamar, J.; Czerny, C. [Univ.-Klinik fuer Radiodiagnostik, Medizinische Universitaet Wien, Abteilung fuer Neuroradiologie und Muskuloskelettale Radiologie, Wien (Austria)

    2009-05-15

    The hip joint is the largest joint in the human body and consequently, its evaluation by diagnostic imaging is highly important. This includes imaging of hip joint arthroplasty, which is used to avoid joint immobility following a wide spectrum of diseases, such as end-stage degenerative disease, avascular necrosis of the femoral head or post-traumatic fractures. Conventional radiography is still the standard imaging modality for the evaluation of hip arthroplasty both directly following surgery and for periodical follow-up. In the majority of cases conventional radiography enables adequate assessment of early and late complications that can arise following hip arthroplasty, such as loosening, prosthetic or periprosthetic fracture, luxation, infection and soft tissue calcification. If the diagnosis cannot be established by means of radiography, advanced imaging methods such as computed tomography (CT) and magnetic resonance imaging (MRI), with or without injection of contrast media, may provide additional information. This is particularly true for the depiction of inflammatory processes. Regardless of the imaging modality used patients' clinical symptoms must also be taken into account in order to establish the correct diagnosis. (orig.) [German] Dem Hueftgelenk als groesstem Gelenk des menschlichen Koerpers kommt eine besondere Bedeutung in der muskuloskelettalen Radiologie zu. Entsprechend wichtig ist auch die radiologische Beurteilung von Hueftgelenkendoprothesen, die z. B. infolge degenerativer Gelenkerkrankungen, einer Hueftkopfnekrose oder einer Fraktur eingesetzt werden. Die Projektionsradiographie ist weiterhin die primaere Modalitaet zur Beurteilung von Hueftgelenkendoprothesen, direkt postoperativ und zur laengerfristigen Verlaufskontrolle. Diese Methode erlaubt in der Mehrzahl der Faelle eine suffiziente Antwort auf die Frage nach Lockerung, periprothetischer Fraktur oder Prothesenmaterialbruch, Luxation, Infektion und Weichteilkalzifikation

  8. Chikungunya Virus Infection: An Update on Joint Manifestations and Management

    Directory of Open Access Journals (Sweden)

    Maria Krutikov

    2016-10-01

    Full Text Available The advent of sophisticated diagnostics has enabled the discovery of previously unknown arthropod-borne viruses like Chikungunya. This infection has become increasingly prevalent in the last 10 years across the Indian Ocean and has been brought to media attention by a recent outbreak in the Caribbean. The outbreak has been aided by a drastic rise in air travel, allowing infected individuals to transport the virus to previously unaffected regions. In addition, a recently documented viral mutation has allowed its transmission by the Aedes albopictus mosquito, therefore facilitating outbreaks in Southern Europe and the USA. The duration and extent of the arthritis seen peri- and post infection has become a topic of academic interest. Although published data are largely observational, there has been a definite increase in original research focusing on this. Symptoms can persist for years, particularly in older patients with pre-existing medical conditions. The etiology is still not fully understood, but viral persistence and immune activation within synovial fluid have been shown in mouse models. There have been no prospective clinical trials of treatment in humans; however, animal trials are in process. The mainstay of treatment remains anti-inflammatories and steroids where necessary. The clinical presentation seems to mimic common rheumatological conditions like rheumatoid arthritis; therefore recent recommendations suggest the use disease-modifying agents as a common practice for the specific syndrome. This review uses recent published data and draws on our own clinical experience to provide an overview of joint complications of Chikungunya infection.

  9. Fluoroscopy- vs ultrasound-guided aspiration techniques in the management of periprosthetic joint infection: which is the best?

    Science.gov (United States)

    Randelli, Filippo; Brioschi, Marco; Randelli, Pietro; Ambrogi, Federico; Sdao, Silvana; Aliprandi, Alberto

    2018-01-01

    Fluid samples obtained from an affected joint still play a central role in the diagnosis of periprosthetic joint infection (PJI). It is the only preoperative test able to discover the causative microbiological agent. In the hip, fluid aspiration can be performed through fluoroscopy, ultrasound, or, less commonly, computed tomography. However, there is still a lack of consensus on which method is preferable in terms of efficacy and costbenefit. We, therefore, asked whether (1) the benefits in terms of sensitivity and specificity and (2) the costs were comparable between fluoroscopy- and ultrasound-guided joint aspirations in a suspicious of hip PJI. Between 2013 and 2016, 52 hip aspirations were performed on 49 patients with clinical, radiological, or serological suspicion of PJI, waiting for a revision surgery. The patients were divided in two groups: fluoroscopy- (n = 26) vs ultrasound-guided hip aspiration group (n = 26). These groups were also divided in control and infected patients. The criteria of MusculoSkeletal Infection Society (MSIS) were used, as gold standard, to define PJI. (1) Ultrasound-guided aspiration revealed valid sensitivity (89% vs 60%) and specificity (94% vs 81%) in comparison with fluoroscopic-guided aspiration. (2) The cost analysis was also in favor of ultrasound-guided aspiration (125.30€) than fluoroscopic-guided aspiration (343.58€). We concluded that ultrasound-guided hip aspiration could represent a valid, safe, and less expensive diagnostic alternative to fluoroscopic-guided aspiration in hip PJI.

  10. Energetic and Peak Power Advantages of Series Elastic Actuators in an Actuated Prosthetic Leg for Walking and Running

    Directory of Open Access Journals (Sweden)

    Martin Grimmer

    2014-02-01

    Full Text Available A monoarticular series elastic actuator (SEA reduces energetic and peak power requirements compared to a direct drive (DD in active prosthetic ankle-foot design. Simulation studies have shown that similar advantages are possible for the knee joint. The aims of this paper were to investigate the advantages of a monoarticular SEA-driven hip joint and to quantify the energetic benefit of an SEA-driven leg (with monoarticular hip, knee and ankle SEAs, assuming that damping (negative power is passively achieved. The hip SEA provided minor energetic advantages in walking (up to 29% compared to the knee and the ankle SEA. Reductions in required peak power were observed only for speeds close to preferred walking speed (18% to 27%. No energetic advantages were found in running, where a DD achieved the best performance when optimizing for energy. Using an SEA at each leg joint in the sagittal plane reduced the positive work by 14% to 39% for walking and by 37% to 75% for running. When using an SEA instead of a DD, the contribution of the three leg joints to doing positive work changed: the knee contributed less and the hip more positive work. For monoarticular SEAs, the ankle joint motor did most of the positive work.

  11. Embodied prosthetic arm stabilizes body posture, while unembodied one perturbs it.

    Science.gov (United States)

    Imaizumi, Shu; Asai, Tomohisa; Koyama, Shinichi

    2016-10-01

    Senses of ownership (this arm belongs to me) and agency (I am controlling this arm) originate from sensorimotor system. External objects can be integrated into the sensorimotor system following long-term use, and recognized as one's own body. We examined how an (un)embodied prosthetic arm modulates whole-body control, and assessed the components of prosthetic embodiment. Nine unilateral upper-limb amputees participated. Four frequently used their prosthetic arm, while the others rarely did. Their postural sway was measured during quiet standing with or without their prosthesis. The frequent users showed greater sway when they removed the prosthesis, while the rare users showed greater sway when they fitted the prosthesis. Frequent users reported greater everyday feelings of postural stabilization by prosthesis and a larger sense of agency over the prosthesis. We suggest that a prosthetic arm maintains or perturbs postural control, depending on the prosthetic embodiment, which involves sense of agency rather than ownership. Copyright © 2016 Elsevier Inc. All rights reserved.

  12. Fixed prosthetic treatment in patients with cleft lip and palate

    Directory of Open Access Journals (Sweden)

    Bajevska Jagoda

    2017-01-01

    Full Text Available Introduction. The prosthetic treatment of patients with cleft palate includes various treatment options such as fixed partial dentures, removable partial prosthesis, etc. The type of prosthetic appliance is determined by the oral health of each individual and the circumstances. We presented three adult patients with the cleft lip and palate subjected to prosthetic treatment. Case report. From the possible prosthetic solutions according to the conditions in the oral cavity and the circumstances, fixed partial dentures veneered with composite or ceramic were chosen. A proper relationship between the teeth was reached with the fixed partial dentures, and function established, the phonetics improved and satisfying aesthetics effect accomplished improving the profile appearance of the patient’s face. Plastic surgery of the nose was performed after that. Conclusion. Multidisclipinary treatment is necessary for favourable long-term outcome in cleft lip and palate patients.

  13. BIOLOGIC JOINT RECONSTRUCTION: ALTERNATIVES TO ARTHROPLASTY

    Directory of Open Access Journals (Sweden)

    Brian J. Cole

    2009-06-01

    limited prosthetic resurfacing. Section VI is "Operative treatment-elbow" including chapters arthroscopy, nonprosthetic elbow arthroplasty, biological resurfacing. The Section VII is "Operative treatment-foot and ankle" including chapters about ankle arthroscopy and cartilage repair in the ankle.The text is one of the most comprehensive and up-to-date references in the treatment of cartilage pathologies and biological joint reconstruction. Some other minimal invasive surgical techniques such as prosthetic partial resurfacing or some osteotomies are also subjected as other alternative treatments for joint restoration. Basic sciences, diagnostic imaging, pharmacological treatment and neutraceuticals, and rehabilitation are making the text. The chapter about future developments in cartilage repair is not only describing the recent technology, different types of tissue engineering and related centers in the world but also gives an idea for the possibilities of future in cartilage repair. Chapters about surgical techniques and procedures are uniformly composed of parts including introduction, preoperative evaluation, surgical technique, postoperative issues, results and references in which the techniques and management described in detail. Numerous high quality images, rich illustrations and figures, page design and also colored tables about key points, protocols, or helpful hints makes the reading and understanding easier

  14. Prosthetic Mitral Valve Leaflet Escape

    Science.gov (United States)

    Kim, Darae; Hun, Sin Sang; Cho, In-Jeong; Shim, Chi-Young; Ha, Jong-Won; Chung, Namsik; Ju, Hyun Chul; Sohn, Jang Won

    2013-01-01

    Leaflet escape of prosthetic valve is rare but potentially life threatening. It is essential to make timely diagnosis in order to avoid mortality. Transesophageal echocardiography and cinefluoroscopy is usually diagnostic and the location of the missing leaflet can be identified by computed tomography (CT). Emergent surgical correction is mandatory. We report a case of fractured escape of Edward-Duromedics mitral valve 27 years after the surgery. The patient presented with symptoms of acute decompensated heart failure and cardiogenic shock. She was instantly intubated and mechanically ventilated. After prompt evaluation including transthoracic echocardiography and CT, the escape of the leaflet was confirmed. The patient underwent emergent surgery for replacement of the damaged prosthetic valves immediately. Eleven days after the surgery, the dislodged leaflet in iliac artery was removed safely and the patient recovered well. PMID:23837121

  15. Adapting to change: influence of a microprocessor-controlled prosthetic knee on gait adaptations

    NARCIS (Netherlands)

    Prinsen, Erik Christiaan

    2016-01-01

    Advancement in prosthetic knee design have led to the introduction of microprocessor-controlled prosthetic knees (MPKs). MPKs incorporate sensors that are able to measure prosthetic loading, the knee angle, and knee angular velocity. Based on the sensor information, MPKs determine the optimal level

  16. Surgical management for active infective endocarditis: a single hospital 10 years experience

    International Nuclear Information System (INIS)

    Parvizi, R.; Varshouchi, M.; Alizadeh, R.

    2007-01-01

    To examine the outcome of surgery for active infective endocarditis (IE) in a cohort of patients. One hundred sixty-four consecutive patients who underwent valve surgery for active IE (diagnosis according to Duke criteria) in Madani Heart Center, Tabriz, Iran from 1996 to 2006 were studied. The mean age of patients was 36.3+-16 years overall: 34.6+-17.5 years for native valve endocarditis and 38.6+-15.2 yrs for prosthetic valve endocarditis (p=0.169). Ninety one (55.5%) patients were men. The infected valve was native in 112 (68.7%) of patients and prosthetic in 52(31.3%). In 61 (37%) patients, no predisposing heart disease was found. The aortic valve was infected in 78 (47.6%), mitral valve in 69 (42.1%), and multiple valves in 17 (10.3%) of patients. Active culture positive endocarditis was present in 81 (49.4%) whereas 83 (50.6%) patients had culture-negative endocarditis. Staphylococcus aureus was the most common isolated microorganism. Ninety patients (54.8%) were in NYHA classes III and IV. Mechanical valves were implanted in 69 patients (42.1%) and bioprostheses in 95 (57.9%), including a homograft in 19 (11.5%). There were 16 (9%) operative deaths, but there was only 1 death in patients that underwent aortic homograft replacement. Reoperation was required in 18 (10.9%) of cases. On multivariate logistic regression analysis, Staphylococcus aureus infection (p=0.008), prosthetic valve endocarditis (p=0.01), paravalvular abscess (p=0.001) and left ventricular ejection fraction less than 40% (p=0.04) were independent predictors of in-hospital mortality. Surgery for infective endocarditis continues to be challenging and associated with high operative mortality and morbidity. Prosthetic valve endocarditis, impaired ventricular function, paravalvular abscess and Staphylococcus aureus infection adversely affect in-hospital mortality. Also we found that aortic valve replacement with an aortic homograft can be performed with acceptable in hospital mortality and

  17. Development of a 3D-Printed Robotic Prosthetic Arm

    Energy Technology Data Exchange (ETDEWEB)

    Gomez Martinez, M.; Garcia-Miquel, A.; Vidal Martinez, N.

    2016-07-01

    Current prostheses are not affordable to the general public. 3D printing technology may allow low-cost production of such devices, making them more readily accessible to people in need. This contribution presents the set-up and the considerations that have to be taken into account to develop a functional artificial upper limb prototype. The robotic prosthetic arm reported herein was produced entirely using 3D printing technology to demonstrate its feasibility on a limited budget. The project was developed to integrate two different functional modes: a prosthetic application and a remote application. The prosthetic application is intended to emulate existing prosthetic devices using myoelectric sensors. The remote application is conceived as a tool for prevention, by providing the general public with a device that could carry out activities that entail a risk of severe physical injury. This is achieved using a hand-tracking system that allows the robotic arm to copy the user’s movements remotely and in real time. The outcome of the validation tests has been considerably successful for both applications and the total costs are on target. (Author)

  18. 77 FR 12063 - Joint Meeting of the Anti-Infective Drugs Advisory Committee and the Nonprescription Drugs...

    Science.gov (United States)

    2012-02-28

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES Food and Drug Administration [Docket No. FDA-2012-N-0001] Joint Meeting of the Anti-Infective Drugs Advisory Committee and the Nonprescription Drugs Advisory Committee; Notice of Meeting AGENCY: Food and Drug Administration, HHS. ACTION: Notice. This notice announces a forthcoming meeting of a public...

  19. Image segmentation for enhancing symbol recognition in prosthetic vision.

    Science.gov (United States)

    Horne, Lachlan; Barnes, Nick; McCarthy, Chris; He, Xuming

    2012-01-01

    Current and near-term implantable prosthetic vision systems offer the potential to restore some visual function, but suffer from poor resolution and dynamic range of induced phosphenes. This can make it difficult for users of prosthetic vision systems to identify symbolic information (such as signs) except in controlled conditions. Using image segmentation techniques from computer vision, we show it is possible to improve the clarity of such symbolic information for users of prosthetic vision implants in uncontrolled conditions. We use image segmentation to automatically divide a natural image into regions, and using a fixation point controlled by the user, select a region to phosphenize. This technique improves the apparent contrast and clarity of symbolic information over traditional phosphenization approaches.

  20. PEMODELAN PERSAMAAN NEWTON-EULER PADA PENGEMBANGAN PROSTHETIC TANGAN KOSMETIK DALAM MENENTUKAN BESARNYA DAYA PADA SISTEM KABEL EXTERNAL

    Directory of Open Access Journals (Sweden)

    Lobes Herdiman

    2012-01-01

    sebesar 12,5041 watt. Daya yang dihasilkan dapat digunakan sebagai dasar menentukan spesifikasi motor. Spesifikasi motor yaitu tipe motor servo dengan seri PTSV4835 atau SV4835, rpm 55,1, volt (12,13 V, I (4.27 amp, input (51,82 watt, torque ( 47 kg-cm, output (26,60 watt dan efficiency sebesar 51,33%. Kata kunci: Prosthetic tangan kosmetik, functional requirements, 6 model gerakan dasar, Newton Euler, tosi, daya Abstract   Development of Prosthetic hand component consists of the metacarpal, metacarpal pollicis, and fingers. The material used is nylon, the number of components of 87 and 175 grams weight. Ability thumb and index finger an important role in the movement to 6 models. The position of the tip-media Phalanx distalis thumb and index finger meet at one point, so that they can perform the basic hand movements. Testing with empirical experiments on the development of cosmetics Prosthetic hand performed to determine the rotation of the coordinate points on the joints during activities of holdings. Coordinate axis and space axis system where x, y, and z, with zero point set at the base of the main shaft. Model mechanism cosmetics Prosthetic hand with withdrawal system to control an external cable. Measurement of pressure on the thumb with the index finger of 493 grams which is done by means of a dial indicator, measuring the pressure with the thumb middle finger for 487 grams. Load Testing pull cable to open the fingers to be fully open by 4291 grams with a force gauge. Newton-Euler equations to produce the amount of torque through the equation forward (forward and backward (backward. Rotation matrix symbolized xRx +1, with x is the starting point and x +1 is the destination point. Point coordinates on each segment as a degree of freedom on three points, namely the point 0, point 1 and point 2. Rotation matrix calculation using the starting point (origin and the destination point (destination. Fingers 0 points specified in the metacarpophalangeal joints, point 1 on

  1. Development of novel 3D-printed robotic prosthetic for transradial amputees.

    Science.gov (United States)

    Gretsch, Kendall F; Lather, Henry D; Peddada, Kranti V; Deeken, Corey R; Wall, Lindley B; Goldfarb, Charles A

    2016-06-01

    Upper extremity myoelectric prostheses are expensive. The Robohand demonstrated that three-dimensional printing reduces the cost of a prosthetic extremity. The goal of this project was to develop a novel, inexpensive three-dimensional printed prosthesis to address limitations of the Robohand. The prosthesis was designed for patients with transradial limb amputation. It is shoulder-controlled and externally powered with an anthropomorphic terminal device. The user can open and close all five fingers, and move the thumb independently. The estimated cost is US$300. After testing on a patient with a traumatic transradial amputation, several advantages were noted. The independent thumb movement facilitated object grasp, the device weighed less than most externally powered prostheses, and the size was easily scalable. Limitations of the new prosthetic include low grip strength and decreased durability compared to passive prosthetics. Most children with a transradial congenital or traumatic amputation do not use a prosthetic. A three-dimensional printed shoulder-controlled robotic prosthesis provides a cost effective, easily sized and highly functional option which has been previously unavailable. © The International Society for Prosthetics and Orthotics 2015.

  2. Prosthetic prescription in the Netherlands: An interview with clinical experts

    NARCIS (Netherlands)

    Van Der Linde, H.; Geertzen, J.H.B.; Hofstad, C.J.; Van Limbeek, Jacques; Postema, K.

    2004-01-01

    In the process of guideline development for prosthetic prescription in the Netherlands the authors made a study of the daily clinical practice of lower limb prosthetics. Besides the evidence-based knowledge from literature the more implicit knowledge from clinical experts is of importance for

  3. PLANNING OF IMPLANTO‐PROSTHETIC STRUCTURES IN TOTAL EDENTATION ACCORDING TO BIOMECHANICAL CRITERIA

    Directory of Open Access Journals (Sweden)

    N. VASILE

    2013-07-01

    Full Text Available Scope of the study: Analysis of the biomechanical aspects of the implanto‐prosthetic structures for planning the treatment in cases of total edentation.Materials and method: The study was performed in the Clinics of Prosthetics and Oral Implantology, Military Emergency Hospital of Sibiu, on a group of mandibularly totally edentated patients. Planning of the implanto‐pros‐ thetic treatment had in view the peculiarities of total man‐ dibular edentation and observance of the biomechanical principles. Selection of the type of occlusion restoration considered the presence of parafunctions and the nature of the antagonistic arch. Special attention was paid to the direction and intensity of the forces acting in the region of the future prosthetic work. When bruxism was manifested, its preimplantary removal was compulsory.Results and discussion: In fixed prosthetic restaurati‐ ons applied on implants, distribuition of forces obviously depend on the quality of osteo‐acceptance, as well, and also on the elasticity degree of the prosthetic work. In the case of mobilized prosthetic restorations supported on implants, rigidization of implants from the anterior region of the mandible may be obtained by means of a bar. In decreasing order of their elasticity, the materials employed are: acrylate, composites, noble and seminoble alloys, other metals, ceramics. Ceramics confers maximum stability to implants, yet without redeeming the forces. For amortizing the forces and for a progressive charging of the implants, it is recommended that the first (temporary prosthetic restorations should be made of either acrylate or compo‐ sites.Conclusions. Observance of the occlusological princi‐ ples in cases of occlusal reconstruction represents the determining element which assures the osteo‐acceptance of implants and the integrity of prosthetic restaurations.

  4. Myoelectric control of prosthetic hands: state-of-the-art review

    Directory of Open Access Journals (Sweden)

    Geethanjali P

    2016-07-01

    Full Text Available Purushothaman Geethanjali School of Electrical Engineering Department of Control and Automation VIT University, Vellore, Tamil Nadu, India Abstract: Myoelectric signals (MES have been used in various applications, in particular, for identification of user intention to potentially control assistive devices for amputees, orthotic devices, and exoskeleton in order to augment capability of the user. MES are also used to estimate force and, hence, torque to actuate the assistive device. The application of MES is not limited to assistive devices, and they also find potential applications in teleoperation of robots, haptic devices, virtual reality, and so on. The myoelectric control-based prosthetic hand aids to restore activities of daily living of amputees in order to improve the self-esteem of the user. All myoelectric control-based prosthetic hands may not have similar operations and exhibit variation in sensing input, deciphering the signals, and actuating prosthetic hand. Researchers are focusing on improving the functionality of prosthetic hand in order to suit the user requirement with the different operating features. The myoelectric control differs in operation to accommodate various external factors. This article reviews the state of the art of myoelectric prosthetic hand, giving description of each control strategy. Keywords: EMG, assistive device, amputee, myoelectric control, electric powered, body ­powered, bioelectric signal control

  5. Effects of a flat prosthetic foot rocker section on balance and mobility.

    Science.gov (United States)

    Hansen, Andrew; Nickel, Eric; Medvec, Joseph; Brielmaier, Steven; Pike, Alvin; Weber, Marilyn

    2014-01-01

    Previous studies have shown that the effective rocker shape of the physiologic ankle-foot system during standing and fore-aft swaying is much flatter than that used during walking, which indicates a more stable base of support for the standing/swaying activity. Previous work suggests that flat regions within the effective rocker shapes of prosthetic ankle-foot systems could provide enhanced stability for standing balance tasks. An experimental prosthetic foot was altered to provide three different flat region lengths within its effective rocker shape. It was hypothesized that longer flat regions of the effective rocker shape would lead to improved standing balance outcomes and reduced walking performance for unilateral transtibial prosthesis users. However, no significant changes were seen in the balance and mobility outcomes of 12 unilateral transtibial prosthesis users when using the three prosthetic foot conditions. Subjects in the study significantly preferred prosthetic feet with relatively low to moderate flat regions over those with long flat regions. All the subjects without loss of light touch or vibratory sensation selected the prosthetic foot with the shortest flat region. More work is needed to investigate the effects of prosthetic foot properties on balance and mobility of prosthesis users.

  6. Multi-Axis Prosthetic Knee Resembles Alpine Skiing Movements of an Intact Leg

    Directory of Open Access Journals (Sweden)

    Ivan Demšar, Jože Duhovnik, Blaž Lešnik, Matej Supej

    2015-12-01

    Full Text Available The purpose of the study was to analyse the flexion angles of the ski boot, ankle and knee joints of an above-knee prosthesis and to compare them with an intact leg and a control group of skiers. One subject with an above-knee amputation of the right leg and eight healthy subjects simulated the movement of a skiing turn by performing two-leg squats in laboratory conditions. By adding additional loads in proportion to body weight (BW; +1/3 BW, +2/3 BW, +3/3 BW, various skiing regimes were simulated. Change of Flexion Angle (CoFA and Range of Motion (RoM in the ski boot, ankle and knee joints were calculated and compared. An average RoM in the skiing boot on the side of prosthesis (4.4 ± 1.1° was significantly lower compared to an intact leg (5.9 ± 1.8° and the control group (6.5 ± 2.3°. In the ankle joint, the average RoM was determined to be 13.2±2.9° in the prosthesis, 12.7 ± 2.8° in an intact leg and 14.8±3.6 in the control group. However, the RoM of the knee joint in the prosthesis (42.2 ± 4.2° was significantly larger than that of the intact leg (34.7 ± 4.4°. The average RoM of the knee joint in the control group was 47.8 ± 5.4°. The influences of additional loads on the kinematics of the lower extremities were different on the side of the prosthesis and on the intact leg. In contrast, additional loads did not produce any significant differences in the control group. Although different CoFAs in the ski boot, ankle and knee joints were used, an above-knee prosthesis with a built-in multi-axis prosthetic knee enables comparable leg kinematics in simulated alpine skiing.

  7. Vascular complications of prosthetic inter-vertebral discs.

    Science.gov (United States)

    Daly, Kevin J; Ross, E Raymond S; Norris, Heather; McCollum, Charles N

    2006-10-01

    Five consecutive cases of prosthetic inter-vertebral disc displacement with severe vascular complications on revisional surgery are described. The objective of this case report is to warn spinal surgeons that major vascular complications are likely with anterior displacement of inter-vertebral discs. We have not been able to find a previous report on vascular complications associated with anterior displacement of prosthetic inter-vertebral discs. In all five patients the prosthetic disc had eroded into the bifurcation of the inferior vena cava and the left common iliac vein. In three cases the aortic bifurcation was also involved. The fibrosis was so severe that dissecting out the arteries and veins to provide access to the relevant disc proved impossible. Formal division of the left common iliac vein and artery with subsequent repair was our solution. Anterior inter-vertebral disc displacement was associated with severe vascular injury. Preventing anterior disc displacement is essential in disc design. In the event of anterior displacement, disc removal should be planned with a Vascular Surgeon.

  8. Initial Clinical Evaluation of the Modular Prosthetic Limb

    Directory of Open Access Journals (Sweden)

    Briana N. Perry

    2018-03-01

    Full Text Available The Modular Prosthetic Limb (MPL was examined for its feasibility and usability as an advanced, dexterous upper extremity prosthesis with surface electromyography (sEMG control in with two individuals with below-elbow amputations. Compared to currently marketed prostheses, the MPL has a greater number of sequential and simultaneous degrees of motion, as well as wrist modularity, haptic feedback, and individual digit control. The MPL was successfully fit to a 33-year-old with a trans-radial amputation (TR01 and a 30-year-old with a wrist disarticulation amputation (TR02. To preserve anatomical limb length, we adjusted the powered degrees of freedom of wrist motion between users. Motor training began with practicing sEMG and pattern recognition control within the virtual integration environment (VIE. Prosthetic training sessions then allowed participants to complete a variety of activities of daily living with the MPL. Training and Motion Control Accuracy scores quantified their ability to consistently train and execute unique muscle-to-motion contraction patterns. Each user also completed one prosthetic functional metric—the Southampton Hand Assessment Procedure (SHAP for TR01 and the Jebsen-Taylor Hand Function Test (JHFT for TR02. Haptic feedback capabilities were integrated for TR01. TR01 achieved 95% accuracy at 84% of his VIE sessions. He demonstrated improved scores over a year of prosthetic training sessions, ultimately achieving simultaneous control of 13 of the 17 (76% attempted motions. His performance on the SHAP improved from baseline to final assessment with an increase in number of tasks achieved. TR01 also used vibrotactile sensors to successfully discriminate between hard and soft objects being grasped by the MPL hand. TR02 demonstrated 95% accuracy at 79% of his VIE sessions. He demonstrated improved scores over months of prosthetic training sessions, however there was a significant drop in scores initially following a mid

  9. Structural Integration and Control of Peerless Human-like Prosthetic Hand

    Science.gov (United States)

    Dave, Ankit; Muthu, P.; Karthikraj, V.; Latha, S.

    2018-04-01

    Limb damage can create severe disturbance in movement and operative abilities wherein the prosthetic rehabilitation has the potential to replace function and enhance the quality of life. This paper presents a humanlike prosthetic hand using such unique design concept of hand model using artificial bones, ligaments, and tendons controlled using Arduino. Amongst various platforms available, Arduino is known for its adaptability, adoration and low cost. The design of prosthetic hand has a unique structure with all carpal, metacarpal, and phalanges which are bones of the hand. These bones are attached to each other following the pattern of human hand using the polymeric rubber as a functioning ligament. Furthermore, this structure of finger is driven by tendons attached to all fingers and passes through the ligaments working as pulley resulting in more degrees of freedom. The motor can twitch the tendons to achieve the action of fingers. Thus the servos, controlled by an Arduino, are used to regulate the movement mechanism of the prosthetic hand.

  10. Impact of Early Valve Surgery on Outcome of Staphylococcus aureus Prosthetic Valve Infective Endocarditis: Analysis in the International Collaboration of Endocarditis–Prospective Cohort Study

    Science.gov (United States)

    Chirouze, Catherine; Alla, François; Fowler, Vance G.; Sexton, Daniel J.; Corey, G. Ralph; Chu, Vivian H.; Wang, Andrew; Erpelding, Marie-Line; Durante-Mangoni, Emanuele; Fernández-Hidalgo, Nuria; Giannitsioti, Efthymia; Hannan, Margaret M.; Lejko-Zupanc, Tatjana; Miró, José M.; Muñoz, Patricia; Murdoch, David R.; Tattevin, Pierre; Tribouilloy, Christophe; Hoen, Bruno; Clara, Liliana; Sanchez, Marisa; Nacinovich, Francisco; Oses, Pablo Fernandez; Ronderos, Ricardo; Sucari, Adriana; Thierer, Jorge; Casabé, José; Cortes, Claudia; Altclas, Javier; Kogan, Silvia; Spelman, Denis; Athan, Eugene; Harris, Owen; Kennedy, Karina; Tan, Ren; Gordon, David; Papanicolas, Lito; Eisen, Damon; Grigg, Leeanne; Street, Alan; Korman, Tony; Kotsanas, Despina; Dever, Robyn; Jones, Phillip; Konecny, Pam; Lawrence, Richard; Rees, David; Ryan, Suzanne; Feneley, Michael P.; Harkness, John; Jones, Phillip; Ryan, Suzanne; Jones, Phillip; Ryan, Suzanne; Jones, Phillip; Post, Jeffrey; Reinbott, Porl; Ryan, Suzanne; Gattringer, Rainer; Wiesbauer, Franz; Andrade, Adriana Ribas; de Brito, Ana Cláudia Passos; Guimarães, Armenio Costa; Grinberg, Max; Mansur, Alfredo José; Siciliano, Rinaldo Focaccia; Strabelli, Tania Mara Varejao; Vieira, Marcelo Luiz Campos; de Medeiros Tranchesi, Regina Aparecida; Paiva, Marcelo Goulart; Fortes, Claudio Querido; de Oliveira Ramos, Auristela; Ferraiuoli, Giovanna; Golebiovski, Wilma; Lamas, Cristiane; Santos, Marisa; Weksler, Clara; Karlowsky, James A.; Keynan, Yoav; Morris, Andrew M.; Rubinstein, Ethan; Jones, Sandra Braun; Garcia, Patricia; Cereceda, M; Fica, Alberto; Mella, Rodrigo Montagna; Barsic, Bruno; Bukovski, Suzana; Krajinovic, Vladimir; Pangercic, Ana; Rudez, Igor; Vincelj, Josip; Freiberger, Tomas; Pol, Jiri; Zaloudikova, Barbora; Ashour, Zainab; El Kholy, Amani; Mishaal, Marwa; Rizk, Hussien; Aissa, Neijla; Alauzet, Corentine; Alla, Francois; Campagnac, Catherine; Doco-Lecompte, Thanh; Selton-Suty, Christine; Casalta, Jean-Paul; Fournier, Pierre-Edouard; Habib, Gilbert; Raoult, Didier; Thuny, Franck; Delahaye, François; Delahaye, Armelle; Vandenesch, Francois; Donal, Erwan; Donnio, Pierre Yves; Michelet, Christian; Revest, Matthieu; Tattevin, Pierre; Violette, Jérémie; Chevalier, Florent; Jeu, Antoine; Sorel, Claire; Tribouilloy, Christophe; Bernard, Yvette; Chirouze, Catherine; Hoen, Bruno; Leroy, Joel; Plesiat, Patrick; Naber, Christoph; Neuerburg, Carl; Mazaheri, Bahram; Naber, Christoph; Neuerburg, Carl; Athanasia, Sofia; Giannitsioti, Efthymia; Mylona, Elena; Paniara, Olga; Papanicolaou, Konstantinos; Pyros, John; Skoutelis, Athanasios; Sharma, Gautam; Francis, Johnson; Nair, Lathi; Thomas, Vinod; Venugopal, Krishnan; Hannan, Margaret; Hurley, John; Gilon, Dan; Israel, Sarah; Korem, Maya; Strahilevitz, Jacob; Rubinstein, Ethan; Strahilevitz, Jacob; Casillo, Roberta; Cuccurullo, Susanna; Dialetto, Giovanni; Durante-Mangoni, Emanuele; Irene, Mattucci; Ragone, Enrico; Tripodi, Marie Françoise; Utili, Riccardo; Cecchi, Enrico; De Rosa, Francesco; Forno, Davide; Imazio, Massimo; Trinchero, Rita; Tebini, Alessandro; Grossi, Paolo; Lattanzio, Mariangela; Toniolo, Antonio; Goglio, Antonio; Raglio, Annibale; Ravasio, Veronica; Rizzi, Marco; Suter, Fredy; Carosi, Giampiero; Magri, Silvia; Signorini, Liana; Baban, Tania; Kanafani, Zeina; Kanj, Souha S.; Yasmine, Mohamad; Abidin, Imran; Tamin, Syahidah Syed; Martínez, Eduardo Rivera; Soto Nieto, Gabriel Israel; van der Meer, Jan T.M.; Chambers, Stephen; Holland, David; Morris, Arthur; Raymond, Nigel; Read, Kerry; Murdoch, David R.; Dragulescu, Stefan; Ionac, Adina; Mornos, Cristian; Butkevich, O.M.; Chipigina, Natalia; Kirill, Ozerecky; Vadim, Kulichenko; Vinogradova, Tatiana; Edathodu, Jameela; Halim, Magid; Lum, Luh-Nah; Tan, Ru-San; Lejko-Zupanc, Tatjana; Logar, Mateja; Mueller-Premru, Manica; Commerford, Patrick; Commerford, Anita; Deetlefs, Eduan; Hansa, Cass; Ntsekhe, Mpiko; Almela, Manuel; Armero, Yolanda; Azqueta, Manuel; Castañeda, Ximena; Cervera, Carlos; del Rio, Ana; Falces, Carlos; Garcia-de-la-Maria, Cristina; Fita, Guillermina; Gatell, Jose M.; Marco, Francesc; Mestres, Carlos A.; Miró, José M.; Moreno, Asuncion; Ninot, Salvador; Paré, Carlos; Pericas, Joan; Ramirez, Jose; Rovira, Irene; Sitges, Marta; Anguera, Ignasi; Font, Bernat; Guma, Joan Raimon; Bermejo, Javier; Bouza, Emilio; Fernández, Miguel Angel Garcia; Gonzalez-Ramallo, Victor; Marín, Mercedes; Muñoz, Patricia; Pedromingo, Miguel; Roda, Jorge; Rodríguez-Créixems, Marta; Solis, Jorge; Almirante, Benito; Fernandez-Hidalgo, Nuria; Tornos, Pilar; de Alarcón, Arístides; Parra, Ricardo; Alestig, Eric; Johansson, Magnus; Olaison, Lars; Snygg-Martin, Ulrika; Pachirat, Orathai; Pachirat, Pimchitra; Pussadhamma, Burabha; Senthong, Vichai; Casey, Anna; Elliott, Tom; Lambert, Peter; Watkin, Richard; Eyton, Christina; Klein, John L.; Bradley, Suzanne; Kauffman, Carol; Bedimo, Roger; Chu, Vivian H.; Corey, G. Ralph; Crowley, Anna Lisa; Douglas, Pamela; Drew, Laura; Fowler, Vance G.; Holland, Thomas; Lalani, Tahaniyat; Mudrick, Daniel; Samad, Zaniab; Sexton, Daniel; Stryjewski, Martin; Wang, Andrew; Woods, Christopher W.; Lerakis, Stamatios; Cantey, Robert; Steed, Lisa; Wray, Dannah; Dickerman, Stuart A.; Bonilla, Hector; DiPersio, Joseph; Salstrom, Sara-Jane; Baddley, John; Patel, Mukesh; Peterson, Gail; Stancoven, Amy; Afonso, Luis; Kulman, Theresa; Levine, Donald; Rybak, Michael; Cabell, Christopher H.; Baloch, Khaula; Chu, Vivian H.; Corey, G. Ralph; Dixon, Christy C.; Fowler, Vance G.; Harding, Tina; Jones-Richmond, Marian; Pappas, Paul; Park, Lawrence P.; Redick, Thomas; Stafford, Judy; Anstrom, Kevin; Athan, Eugene; Bayer, Arnold S.; Cabell, Christopher H.; Chu, Vivian H.; Corey, G. Ralph; Fowler, Vance G.; Hoen, Bruno; Karchmer, A. W.; Miró, José M.; Murdoch, David R.; Sexton, Daniel J.; Wang, Andrew; Bayer, Arnold S.; Cabell, Christopher H.; Chu, Vivian; Corey, G. Ralph; Durack, David T.; Eykyn, Susannah; Fowler, Vance G.; Hoen, Bruno; Miró, José M.; Moreillon, Phillipe; Olaison, Lars; Raoult, Didier; Rubinstein, Ethan; Sexton, Daniel J.

    2015-01-01

    Background. The impact of early valve surgery (EVS) on the outcome of Staphylococcus aureus (SA) prosthetic valve infective endocarditis (PVIE) is unresolved. The objective of this study was to evaluate the association between EVS, performed within the first 60 days of hospitalization, and outcome of SA PVIE within the International Collaboration on Endocarditis–Prospective Cohort Study. Methods. Participants were enrolled between June 2000 and December 2006. Cox proportional hazards modeling that included surgery as a time-dependent covariate and propensity adjustment for likelihood to receive cardiac surgery was used to evaluate the impact of EVS and 1-year all-cause mortality on patients with definite left-sided S. aureus PVIE and no history of injection drug use. Results. EVS was performed in 74 of the 168 (44.3%) patients. One-year mortality was significantly higher among patients with S. aureus PVIE than in patients with non–S. aureus PVIE (48.2% vs 32.9%; P = .003). Staphylococcus aureus PVIE patients who underwent EVS had a significantly lower 1-year mortality rate (33.8% vs 59.1%; P = .001). In multivariate, propensity-adjusted models, EVS was not associated with 1-year mortality (risk ratio, 0.67 [95% confidence interval, .39–1.15]; P = .15). Conclusions. In this prospective, multinational cohort of patients with S. aureus PVIE, EVS was not associated with reduced 1-year mortality. The decision to pursue EVS should be individualized for each patient, based upon infection-specific characteristics rather than solely upon the microbiology of the infection causing PVIE. PMID:25389255

  11. Control system and method for prosthetic devices

    Science.gov (United States)

    Bozeman, Richard J., Jr. (Inventor)

    1992-01-01

    A control system and method for prosthetic devices is provided. The control system comprises a transducer for receiving movement from a body part for generating a sensing signal associated with that movement. The sensing signal is processed by a linearizer for linearizing the sensing signal to be a linear function of the magnitude of the distance moved by the body part. The linearized sensing signal is normalized to be a function of the entire range of body part movement from the no-shrug position of the movable body part through the full-shrug position of the movable body part. The normalized signal is divided into a plurality of discrete command signals. The discrete command signals are used by typical converter devices which are in operational association with the prosthetic device. The converter device uses the discrete command signals for driving the movable portions of the prosthetic device and its sub-prosthesis. The method for controlling a prosthetic device associated with the present invention comprises the steps of receiving the movement from the body part, generating a sensing signal in association with the movement of the body part, linearizing the sensing signal to be a linear function of the magnitude of the distance moved by the body part, normalizing the linear signal to be a function of the entire range of the body part movement, dividing the normalized signal into a plurality of discrete command signals, and implementing the plurality of discrete command signals for driving the respective movable prosthesis device and its sub-prosthesis.

  12. Diagnosis of infected bone and joint diseases with 99mTc-HM-PAO labeled leukocytes

    International Nuclear Information System (INIS)

    Kanegae, Kakuko; Itoh, Kazuo; Tsukamoto, Eriko; Nagao, Kazuhiko; Nakada, Kunihiro; Hurudate, Masayori

    1992-01-01

    The usefulness of 99m Tc-hexamethylpropylene amine oxime (HM-PAO) labeled leukocytes scans was studied in 15 patients with suspected infection of the bone and joints. All spot images of lesions were obtained 4 and 24 hours after injection of 70.3-236.8 MBq (a mean, 149.5 MBq). 99m Tc-HM-PAO leukocytes scans were positive in 5 patients, negative in 8, and equivocal in 2. It had a sensitivity of 83% (5/6), specificity of 100% (6/6), and accuracy of 93% (14/15) for diagnosing infections. Equivocal uptake, seen on the 4-hr image in 2 patients, became negative on the 24-hr image. In view of ready availability and simple labeling procedure, 99m Tc-HM-PAO labeled leukocytes scans can be used as one of the specific diagnostic procedures for infections. (N.K.)

  13. Rehand: Realistic electric prosthetic hand created with a 3D printer.

    Science.gov (United States)

    Yoshikawa, Masahiro; Sato, Ryo; Higashihara, Takanori; Ogasawara, Tsukasa; Kawashima, Noritaka

    2015-01-01

    Myoelectric prosthetic hands provide an appearance with five fingers and a grasping function to forearm amputees. However, they have problems in weight, appearance, and cost. This paper reports on the Rehand, a realistic electric prosthetic hand created with a 3D printer. It provides a realistic appearance that is same as the cosmetic prosthetic hand and a grasping function. A simple link mechanism with one linear actuator for grasping and 3D printed parts achieve low cost, light weight, and ease of maintenance. An operating system based on a distance sensor provides a natural operability equivalent to the myoelectric control system. A supporter socket allows them to wear the prosthetic hand easily. An evaluation using the Southampton Hand Assessment Procedure (SHAP) demonstrated that an amputee was able to operate various objects and do everyday activities with the Rehand.

  14. Cementless One-Stage Revision in Chronic Periprosthetic Hip Joint Infection. Ninety-One Percent Infection Free Survival in 56 Patients at Minimum 2-Year Follow-Up

    DEFF Research Database (Denmark)

    Lange, Jeppe; Troelsen, Anders; Solgaard, Søren

    2018-01-01

    was re-revision performed due to infection and was evaluated by competing risk analysis, with death and aseptic revision as competing events. All-cause mortality was evaluated by Kaplan-Meier survival analysis. Oxford Hip Score (OHS) was used as disease-specific patient-reported outcome measure. RESULTS......BACKGROUND: Cementless 1-stage revision in chronic periprosthetic hip joint infections is limited evaluated. The purpose of this study was to evaluate a specific treatment protocol in this patient group. METHODS: The study was performed as a multicenter, proof-of-concept, observational study...

  15. Diagnostic value of imaging in infective endocarditis: a systematic review.

    Science.gov (United States)

    Gomes, Anna; Glaudemans, Andor W J M; Touw, Daan J; van Melle, Joost P; Willems, Tineke P; Maass, Alexander H; Natour, Ehsan; Prakken, Niek H J; Borra, Ronald J H; van Geel, Peter Paul; Slart, Riemer H J A; van Assen, Sander; Sinha, Bhanu

    2017-01-01

    Sensitivity and specificity of the modified Duke criteria for native valve endocarditis are both suboptimal, at approximately 80%. Diagnostic accuracy for intracardiac prosthetic material-related infection is even lower. Non-invasive imaging modalities could potentially improve diagnosis of infective endocarditis; however, their diagnostic value is unclear. We did a systematic literature review to critically appraise the evidence for the diagnostic performance of these imaging modalities, according to PRISMA and GRADE criteria. We searched PubMed, Embase, and Cochrane databases. 31 studies were included that presented original data on the performance of electrocardiogram (ECG)-gated multidetector CT angiography (MDCTA), ECG-gated MRI, 18 F-fluorodeoxyglucose ( 18 F-FDG) PET/CT, and leucocyte scintigraphy in diagnosis of native valve endocarditis, intracardiac prosthetic material-related infection, and extracardiac foci in adults. We consistently found positive albeit weak evidence for the diagnostic benefit of 18 F-FDG PET/CT and MDCTA. We conclude that additional imaging techniques should be considered if infective endocarditis is suspected. We propose an evidence-based diagnostic work-up for infective endocarditis including these non-invasive techniques. Copyright © 2017 Elsevier Ltd. All rights reserved.

  16. A comparison of self-reported joint symptoms following infection with different enteric pathogens: effect of HLA-B27

    DEFF Research Database (Denmark)

    Schiellerup, P.; Krogfelt, K.A.; Locht, H.

    2008-01-01

    with positive fecal culture for Salmonella, Campylobacter, Yersinia, Shigella, and E. coli were addressed by questionnaires inquiring about gastrointestinal (GI) symptoms and the occurrence of joint pain in a previously healthy joint within 4 weeks after onset of infection. A blood sample was requested for HLA......-B27 typing. RESULTS: Of 3146 patients invited, 2105 (67%) responded to the survey questionnaire. The triggering infections were Campylobacter, 1003; Salmonella, 619; E. coli, 290; Shigella, 102; and Yersinia, 91. JPrea was reported by 294 subjects: Campylobacter, 131 (13.1%); Salmonella, 104 (16.......8%); Yersinia, 21 (23.1%); Shigella, 10 (9.8%); and E. coli, 28 (9.7%). There was a significant association between severity of gastroenteritis and development of arthralgia (p = 0.001). The odds ratio (OR) for JPrea in an HLA-B27-positive individual was 2.62 (95% CI 1.67-3.93) for the entire group...

  17. 18F-FDG-PET/CT Angiography for the Diagnosis of Infective Endocarditis.

    Science.gov (United States)

    Roque, A; Pizzi, M N; Cuéllar-Calàbria, H; Aguadé-Bruix, S

    2017-02-01

    This article reviews the current imaging role of 18 F-fluordeoxyglucose positron emission computed tomography ( 18 F-FDG-PET/CT) combined with cardiac CT angiography (CTA) in infective endocarditis and discusses the strengths and limitations of this technique. The diagnosis of infective endocarditis affecting prosthetic valves and intracardiac devices is challenging because echocardiography and, therefore, the modified Duke criteria have well-recognized limitations in this clinical scenario. The high sensitivity of 18 F-FDG-PET/CT for the detection of infection associated with the accurate definition of structural damage by gated cardiac CTA in a combined technique (PET/CTA) has provided a significant increase in diagnostic sensitivity for the detection of IE. PET/CTA has proven to be a useful diagnostic tool in patients with suspected infective endocarditis. The additional information provided by this technique improves diagnostic performance in prosthetic valve endocarditis when it is used in combination with the Duke criteria. The findings obtained in PET/CTA studies have been included as a major criterion in the recently updated diagnostic algorithm in infective endocarditis guidelines.

  18. Infection of PTFE mesh 15 years following pedicled TRAM flap breast reconstruction: mechanism and aetiology.

    Science.gov (United States)

    Elfaki, A; Gkorila, A; Khatib, M; Malata, C M

    2018-01-01

    The pedicled transverse rectus abdominis myocutaneous (TRAM) flap procedure is still widely used for breast reconstruction. The repair of the flap harvest site in the transverse rectus abdominis muscle and sheath is often assisted by the use of prosthetic meshes. This decreases the risk of abdominal wall weakness and herniation but, being a foreign body, it also carries the risk of infection. In this report, we describe the case of a 63-year-old patient who, whilst receiving chemotherapy for metastatic breast cancer, presented with an infected polytetrafluoroethylene mesh 15 years after pedicled TRAM flap immediate breast reconstruction. This necessitated mesh removal to treat the infection. Following a thorough review of the English literature, this is the longest recorded presentation of an abdominal prosthetic mesh infection. The mechanism and aetiology of such a late complication are discussed.

  19. Does positron emission tomography/computed tomography aid the diagnosis of prosthetic valve infective endocarditis?

    Science.gov (United States)

    Balmforth, Damian; Chacko, Jacob; Uppal, Rakesh

    2016-10-01

    A best evidence topic was constructed according to a structured protocol. The question addressed was whether (18)F-fluorodeoxyglucose positron emission tomography/computed tomography (PET/CT) aids the diagnosis of prosthetic valve endocarditis (PVE)? A total of 107 publications were found using the reported search, of which 6 represented the best evidence to answer the clinical question. The authors, journal, date and country of publication, patient group studied, study type, relevant outcomes and results of these papers are tabulated. The reported outcome of all studies was a final diagnosis of confirmed endocarditis on follow-up. All the six studies were non-randomized, single-centre, observational studies and thus represented level 3 evidence. The diagnostic capability of PET/CT for PVE was compared with that of the modified Duke Criteria and echocardiography, and reported in terms of sensitivity, specificity and positive and negative predictive values. All studies demonstrated an increased sensitivity for the diagnosis of PVE when PET/CT was combined with the modified Duke Criteria on admission. A higher SUVmax on PET was found to be significantly associated with a confirmed diagnosis of endocarditis and an additional diagnostic benefit of PET/CT angiography over conventional PET/non-enhanced CT is reported due to improved anatomical resolution. However, PET/CT was found to be unreliable in the early postoperative period due to its inability to distinguish between infection and residual postoperative inflammatory changes. PET/CT was also found to be poor at diagnosing cases of native valve endocarditis. We conclude that PET/CT aids in the diagnosis of PVE when combined with the modified Duke Criteria on admission by increasing the diagnostic sensitivity. The diagnostic ability of PET/CT can be potentiated by the use of PET/CTA; however, its use may be unreliable in the early postoperative period or in native valve endocarditis. © The Author 2016. Published by

  20. COMPARISON OF CULTURE OF SYNOVIAL FLUID, PERIPROSTHETIC TISSUE AND PROSTHESIS SONICATE FOR THE DIAGNOSIS OF KNEE PROSTHESIS INFECTION

    Directory of Open Access Journals (Sweden)

    Andrej Trampuž

    2003-03-01

    Full Text Available Background. Synovial fluid and periprosthetic tissue specimens are the standard specimens cultured for the diagnosis of prosthetic joint infection (PJI. We hypothesize that ultrasonication of the explanted prosthesis may improve diagnosis of PJI by dislodging biofilm bacteria from the prosthesis surface and improve the sensitivity and specificity of diagnosis of PJI.Methods. Included were patients undergoing knee prosthesis exchange for septic or biomechanical failure and have not received antimicrobial therapy in the last 2 weeks prior specimen collection. Cultures of synovial fluid and periprosthetic tissue specimens were performed per the usual clinical practice. Additionally, explanted joint components were sonicated for 5 minutes at frequency 40 kHz in sterile Ringer’s solution; aliquots of 0.5 ml sonicate were plated onto five aerobic and five anaerobic blood agar plates, and incubated at 37 °C and examined for the next seven days. The number and identity of each colony morphology was recorded.Results. 35 patients undergoing knee replacement have been studied (24 for aseptic biomechanical failure and 11 for suspected PJI. In patients with PJI, coagulase-negative staphylococci (7 cases, Corynebacterium spp. (2 cases, Staphylococcus aureus (1 case, and viridans group streptococcus (1 case were recovered. Culture sensitivity and specificity were for synovial fluid 88% and 100%, for periprosthetic tissue 83% and 81%, and for explant sonicate 91% and 100%, respectively. In sonicate cultures higher numbers of microorganisms than in periprosthetic tissue cultures were consistently detected.Conclusions. Using synovial fluid, periprosthetic tissue, and explant sonicate cultures, 12%, 17% and 9% of PJI were missed, respectively. Explant sonicate cultures were the most sensitive with respect to the diagnosis of PJI, indicating that explant ultrasonication may improve bacterial recovery. In sonicate cultures, infecting organisms were detected in

  1. ORAL HYGIENE OF PROSTHETIC DENTURE USER IN KODINGARENG ISLAND

    OpenAIRE

    NUR, NURUL KUSUMADEWI S.KG

    2008-01-01

    Objectives:to determine the level of oral hygiene for prosthetic denture user, especially for full-denture in Kodingareng Island. This researchincluded the distribution level of prosthetic denture user based on age and education.Methods: the method that used in this research is observational descriptive withcross sectional-studyas the research design. Variable result of the research determined in to 3, those are bad, middle, and good. Result:the highest percentage o...

  2. Reduced prosthetic stiffness lowers the metabolic cost of running for athletes with bilateral transtibial amputations.

    Science.gov (United States)

    Beck, Owen N; Taboga, Paolo; Grabowski, Alena M

    2017-04-01

    Inspired by the springlike action of biological legs, running-specific prostheses are designed to enable athletes with lower-limb amputations to run. However, manufacturer's recommendations for prosthetic stiffness and height may not optimize running performance. Therefore, we investigated the effects of using different prosthetic configurations on the metabolic cost and biomechanics of running. Five athletes with bilateral transtibial amputations each performed 15 trials on a force-measuring treadmill at 2.5 or 3.0 m/s. Athletes ran using each of 3 different prosthetic models (Freedom Innovations Catapult FX6, Össur Flex-Run, and Ottobock 1E90 Sprinter) with 5 combinations of stiffness categories (manufacturer's recommended and ± 1) and heights (International Paralympic Committee's maximum competition height and ± 2 cm) while we measured metabolic rates and ground reaction forces. Overall, prosthetic stiffness [fixed effect (β) = 0.036; P = 0.008] but not height ( P ≥ 0.089) affected the net metabolic cost of transport; less stiff prostheses reduced metabolic cost. While controlling for prosthetic stiffness (in kilonewtons per meter), using the Flex-Run (β = -0.139; P = 0.044) and 1E90 Sprinter prostheses (β = -0.176; P = 0.009) reduced net metabolic costs by 4.3-4.9% compared with using the Catapult prostheses. The metabolic cost of running improved when athletes used prosthetic configurations that decreased peak horizontal braking ground reaction forces (β = 2.786; P = 0.001), stride frequencies (β = 0.911; P < 0.001), and leg stiffness values (β = 0.053; P = 0.009). Remarkably, athletes did not maintain overall leg stiffness across prosthetic stiffness conditions. Rather, the in-series prosthetic stiffness governed overall leg stiffness. The metabolic cost of running in athletes with bilateral transtibial amputations is influenced by prosthetic model and stiffness but not height. NEW & NOTEWORTHY We measured the

  3. [Treatment of the infected wound with exposed silver-ring vascular graft and delayed Thiersch method of skin transplant covering ].

    Science.gov (United States)

    Nenezić, Dragoslav; Pandaitan, Simon; Ilijevski, Nenad; Matić, Predrag; Gajin, Predag; Radak, Dorde

    2005-01-01

    Although the incidence of prosthetic infection is low (1%-6%), the consequences (limb loss or death) are dramatic for a patient, with high mortality rate (25%-75%) and limb loss in 40%-75% of cases. In case of Szilagyi's grade III infection, standard procedure consists of the excision of prosthesis and wound debridement. Alternative method is medical treatment. This is a case report of a patient with prosthetic infection of Silver-ring graft, used for femoropopliteal reconstruction, in whom an extreme skin necrosis developed in early postoperative period. This complication was successfully treated medically. After repeated debridement and wound-packing, the wound was covered using Thiersch skin graft.

  4. Clinical Effectiveness of Using Aesthetic Fixed Prosthetic Appliances with Combined Occlusal Surface

    OpenAIRE

    Andrii Biben; Zinovii Ozhohan

    2017-01-01

    The objective of the research was to evaluate the clinical effectiveness of using aesthetic fixed prosthetic appliances with combined occlusal surface. Materials and methods. The study included 30 patients who were divided into 2 groups: Group I included 20 patients with combined occlusal surface of the crowns; Group II included 22 patients with ceramic occlusal surface of the crowns. The patients were observed 3, 6 and 12 months after prosthetic repair. Results. 6 months after prosthet...

  5. Control of a powered prosthetic device via a pinch gesture interface

    Science.gov (United States)

    Yetkin, Oguz; Wallace, Kristi; Sanford, Joseph D.; Popa, Dan O.

    2015-06-01

    A novel system is presented to control a powered prosthetic device using a gesture tracking system worn on a user's sound hand in order to detect different grasp patterns. Experiments are presented with two different gesture tracking systems: one comprised of Conductive Thimbles worn on each finger (Conductive Thimble system), and another comprised of a glove which leaves the fingers free (Conductive Glove system). Timing tests were performed on the selection and execution of two grasp patterns using the Conductive Thimble system and the iPhone app provided by the manufacturer. A modified Box and Blocks test was performed using Conductive Glove system and the iPhone app provided by Touch Bionics. The best prosthetic device performance is reported with the developed Conductive Glove system in this test. Results show that these low encumbrance gesture-based wearable systems for selecting grasp patterns may provide a viable alternative to EMG and other prosthetic control modalities, especially for new prosthetic users who are not trained in using EMG signals.

  6. Validation and Application of a Dried Blood Spot Assay for Biofilm-Active Antibiotics Commonly Used for Treatment of Prosthetic Implant Infections

    Science.gov (United States)

    Knippenberg, Ben; Page-Sharp, Madhu; Clark, Ben; Dyer, John; Batty, Kevin T.; Davis, Timothy M. E.

    2016-01-01

    Dried blood spot (DBS) antibiotic assays can facilitate pharmacokinetic (PK)/pharmacodynamic (PD) studies in situations where venous blood sampling is logistically difficult. We sought to develop, validate, and apply a DBS assay for rifampin (RIF), fusidic acid (FUS), and ciprofloxacin (CIP). These antibiotics are considered active against organisms in biofilms and are therefore commonly used for the treatment of infections associated with prosthetic implants. A liquid chromatography-mass spectroscopy DBS assay was developed and validated, including red cell partitioning and thermal stability for each drug and the rifampin metabolite desacetyl rifampin (Des-RIF). Plasma and DBS concentrations in 10 healthy adults were compared, and the concentration-time profiles were incorporated into population PK models. The limits of quantification for RIF, Des-RIF, CIP, and FUS in DBS were 15 μg/liter, 14 μg/liter, 25 μg/liter, and 153 μg/liter, respectively. Adjusting for hematocrit, red cell partitioning, and relative recovery, DBS-predicted plasma concentrations were comparable to measured plasma concentrations for each antibiotic (r > 0.95; P < 0.0001), and Bland-Altman plots showed no significant bias. The final population PK estimates of clearance, volume of distribution, and time above threshold MICs for measured and DBS-predicted plasma concentrations were comparable. These drugs were stable in DBSs for at least 10 days at room temperature and 1 month at 4°C. The present DBS antibiotic assays are robust and can be used as surrogates for plasma concentrations to provide valid PK and PK/PD data in a variety of clinical situations, including therapeutic drug monitoring or studies of implant infections. PMID:27270283

  7. 3D reconstruction of bony elements of the knee joint and finite element analysis of total knee prosthesis obtained from the reconstructed model.

    Science.gov (United States)

    Djoudi, Farid

    2013-01-01

    Two separate themes are presented in this paper. The first theme is to present a graphical modeling approach of human anatomical structures namely, the femur and the tibia. The second theme involves making a finite element analysis of stresses, displacements and deformations in prosthetic implants (the femoral implant and the polyethylene insert). The graphical modeling approach comes in two parts. The first is the segmentation of MRI scanned images, retrieved in DICOM format for edge detection. In the second part, 3D-CAD models are generated from the results of the segmentation stage. The finite element analysis is done by first extracting the prosthetic implants from the reconstructed 3D-CAD model, then do a finite element analysis of these implants under objectively determined conditions such as; forces, allowed displacements, the materials composing implant, and the coefficient of friction. The objective of this work is to implement an interface for exchanging data between 2D MRI images obtained from a medical diagnosis of a patient and the 3D-CAD model used in various applications, such as; the extraction of the implants, stress analysis at the knee joint and can serve as an aid to surgery, also predict the behavior of the prosthetic implants vis-a-vis the forces acting on the knee joints.

  8. LOW-MOLECULAR-WEIGHT HEPARIN TREATMENT FAILURE IN PREVENTION OF PROSTHETIC MITRAL VALVE THROMBOSIS

    OpenAIRE

    David Šuran; Vojko Kanič; Tatjana Golob Gulič; Husam Franjo Naji; Robert Lipovec

    2009-01-01

    Background Prosthetic heart valve thrombosis (PHVT) represents a dangerous postoperative complication following prosthetic heart valve replacement. Incidence varies according to different data from 0.5–4 % per year following mitral or aortic valve replacement in spite of adequate oral anticoagulation with coumarins. Case report We are presenting a case of prosthetic mitral valve thrombosis as a result of 6-month lowmolecular-weight heparin (LMWH) (nadroparine) treatment failure. Our pat...

  9. Obtention of a prosthetic group for labelling of radioiodinated proteins

    International Nuclear Information System (INIS)

    Santos, Josefina da S.; Colturato, Maria Tereza; Araujo, Elaine B. de

    2000-01-01

    Antibodies and peptides labeled with radionuclides has been extensively used in radioimmunotherapy and radioimmunodetection. The principal problem with the use of radioiodinated proteins is the in vivo dehalogenation. The use of prosthetic groups for indirect labeling of proteins with radioiodine has showed to be useful on labeling proteins with greater in vivo stability. A procedure is described for the preparation of an radioiodinated prosthetic group (N-succinimidyl 4-radioiodine-benzoate-SIB), using procedure described by Stocklin et al, with the iodination of p-bromo-benzoic acid and subsequent reaction with TSTU. Preliminary labeling results showed that the prosthetic group can be obtained in a good yield. The coupling of the SIB to the protein will be studied using human IgG as protein model. (author)

  10. Fatigue limits of titanium-bar joints made with the laser and the electric resistance welding techniques: microstructural characterization and hardness properties.

    Science.gov (United States)

    Degidi, Marco; Nardi, Diego; Morri, Alessandro; Sighinolfi, Gianluca; Tebbel, Florian; Marchetti, Claudio

    2017-09-01

    Fatigue behavior of the titanium bars is of utmost importance for the safe and reliable operation of dental implants and prosthetic constructions based on these implants. To date, however, only few data are available on the fatigue strength of dental prostheses made with electric resistance welding and laser welding techniques. This in-vitro study highlighted that although the joints made with the laser welding approach are credited of a superior tensile strength, joints made with electric resistance welding exhibited double the minimum fatigue strength with respect to the joints made with laser welding (120 vs 60 N).

  11. A clinical survey about commercial games in lower limb prosthetic rehabilitation.

    Science.gov (United States)

    Imam, Bita; Miller, William C; Finlayson, Heather C; Eng, Janice J; Jarus, Tal

    2018-06-01

    Despite the popularity of commercial games in lower limb prosthetic rehabilitation, data about their prevalence of use as well as therapists' perspectives about these games are still lacking. To learn about the prevalence of use of commercial games in lower limb prosthetic rehabilitation and therapists' perspectives about these games. Cross-sectional. An online survey was sent to physical and occupational therapists across prosthetic rehabilitation facilities in Canada. The survey had questions about the use of commercial games and therapists' perspectives. Data were collected from 82 therapists. Overall, 46.3% (38/82) reported that they use commercial games; of those, 94.7% (36/38) used the Nintendo Wii Fit. The most reported perceived benefits were the Wii Fit helping to improve weight shifting ( n = 76/82, 92.7%) and balance ( n = 75/82, 91.5%), and being motivating and complementing traditional therapy ( n = 75/82, 91.5%). The most reported perceived barriers/challenges were lack of time and familiarity with the games ( n = 58/82, 70.7%). Commercial games, particularly the Wii Fit, are commonly used in lower prosthetic rehabilitation in Canada. Most of the queried therapists view the Wii Fit positively. Knowledge translation activities and developing standard treatment protocols would be helpful in minimizing the barriers identified in this study. Clinical relevance The Wii Fit is prevalent in lower limb prosthetic rehabilitation in Canada and it is viewed positively by therapists as having the potential to improve balance and weight bearing, making rehabilitation more motivating, and complementing traditional therapy. Future studies should investigate the efficacy of the Wii Fit in prosthetic rehabilitation.

  12. Quality Assessment of Prosthetic Rehabilitation Using Aesthetic Fixed Restorations

    Directory of Open Access Journals (Sweden)

    Zinovii Ozhohan

    2018-04-01

    Full Text Available The objective of the research was to study and assess the quality of prosthetic treatment using aesthetic fixed restorations. Materials and methods. The study included 79 patients without a comorbidity who underwent prosthetic rehabilitation. All the patients were divided into 3 groups: Group I included 25 patients with metal-plastic restorations; Group II comprised 34 patients with porcelain-fused-to-metal restorations; Group III consisted of 20 patients with a combined occlusal surface of prosthetic restorations. The patients were observed 6 months after prosthetic repair. Only patients with single molar and premolar crowns were examined. Bridge prostheses were not taken into account in order to eliminate the effect of masticatory force redistribution on the abutment crowns. Results. In Group I, 11 (44% patients were satisfied with the results of prosthetic treatment. In Group II, 25 (78.12% patients reported that they were satisfied with their treatment. In Group III, there were 17 (85% patients satisfied with their outcome. However, the patients’ complaints are often subjective and do not fully reflect the objective state of the dentoalveolar system. An objective examination revealed that in indirect restorations, marginal periodontium pathology is typical. Conclusions. Aesthetic fixed restorations with a combined occlusal surface have demonstrated good clinical results, even at long-term follow-up. Combining positive properties of two different construction materials, namely zirconium dioxide and ceramics, they reduce the risk of complications such as marginal periodontium pathology and chipping along the occlusal surface as well as contribute to minimal abrasion of the occlusal surfaces of the antagonistic teeth. We cannot recommend metal-plastic restorations due to their low clinical effectiveness, poor aesthetic qualities as well as a high level of marginal periodontium pathology.

  13. Effect of Modifying Prosthetic Socket Base Materials by Adding Nanodiamonds

    Directory of Open Access Journals (Sweden)

    Lifang Ma

    2015-01-01

    Full Text Available The curing process of prosthetic socket base materials requires attention owing to a series of associated problems that are yet to be addressed and solved. However, to date, few relevant studies have been reported. In this paper, nanodiamonds modified with a silane coupling agent were dispersed into a prosthetic socket base material, and the performance of the modified base materials was investigated. Adding a predetermined amount of nanodiamonds to the prosthetic socket base material increased the glass transition temperature, improved the mechanical properties of the cured base material, and reduced the influence of the volatile gas formed during the curing process on the environment. With increasing nanodiamond contents, the glass transition temperature increased and the mechanical properties improved slightly. Owing to the high thermal conductivity of the nanodiamonds, the localized heat, as a result of the curing process, could be dissipated and released. Thus, adding nanodiamonds led to a more uniform temperature field forming in the curing system. This improved the curing process and reduced the formation of volatile monomers, thereby decreasing the adverse impact of the generated volatile gases on the environment. All of these provide a potential strategy for modifying prosthetic socket base materials.

  14. Strength evaluation of prosthetic check sockets, copolymer sockets, and definitive laminated sockets.

    Science.gov (United States)

    Gerschutz, Maria J; Haynes, Michael L; Nixon, Derek; Colvin, James M

    2012-01-01

    A prosthesis encounters loading through forces and torques exerted by the person with amputation. International Organization for Standardization (ISO) standard 10328 was designed to test most lower-limb prosthetic components. However, this standard does not include prosthetic sockets. We measured static failure loads of prosthetic sockets using a modified ISO 10328 and then compared them with the criteria set by this standard for other components. Check socket (CS) strengths were influenced by thickness, material choice, and fabrication method. Copolymer socket (CP) strengths depended on thickness and fabrication methods. A majority of the CSs and all of the CPs failed to pass the ISO 10328 ductile loading criterion. In contrast, the strengths of definitive laminated sockets (DLs) were influenced more by construction material and technique. A majority of the DLs failed to pass the ISO 10328 brittle loading criterion. Analyzing prosthetic sockets from a variety of facilities demonstrated that socket performance varies considerably between and within facilities. The results from this article provide a foundation for understanding the quality of prosthetic sockets, some insight into possible routes for improving the current care delivered to patients, and a comparative basis for future technology.

  15. Diagnostic value of imaging in infective endocarditis : a systematic review

    NARCIS (Netherlands)

    Gomes, Anna; Glaudemans, Andor W J M; Touw, Daan J; van Melle, Joost P; Willems, Tineke P; Maass, Alexander H; Natour, Ehsan; Prakken, Niek H J; Borra, Ronald J H; van Geel, Peter Paul; Slart, Riemer H J A; van Assen, Sander; Sinha, Bhanu

    Sensitivity and specificity of the modified Duke criteria for native valve endocarditis are both suboptimal, at approximately 80%. Diagnostic accuracy for intracardiac prosthetic material-related infection is even lower. Non-invasive imaging modalities could potentially improve diagnosis of

  16. Computed Tomography of Prosthetic Heart Valves

    NARCIS (Netherlands)

    Habets, J.

    2012-01-01

    Prosthetic heart valve (PHV) dysfunction is an infrequent but potentially life-threatening disease with a heterogeneous clinical presentation. Patients with PHV dysfunction clinically can present with symptoms of congestive heart failure (dyspnea, fatigue, edema), fever, angina pectoris, dizziness

  17. Joint Effects of Exposure to Prenatal Infection and Peripubertal Psychological Trauma in Schizophrenia.

    Science.gov (United States)

    Debost, Jean-Christophe P G; Larsen, Janne Tidselbak; Munk-Olsen, Trine; Mortensen, Preben Bo; Meyer, Urs; Petersen, Liselotte

    2017-01-01

    Prenatal infection and traumatizing experiences have both been linked with schizophrenia, but none of these factors seem sufficient to cause the disorder. However, recent evidence suggests that these environmental insults act in synergy to increase schizophrenia risk. To estimate the independent and joint effects of exposure to prenatal infection and peripubertal psychological trauma on the risk of schizophrenia. Danish nationwide registers were linked in this prospective cohort study. We used survival analysis to report incidence rate ratios (IRRs) and corresponding 95% confidence intervals (95% CIs). Analyses were adjusted for age and calendar period and stratified by sex. A total of 979701 persons born between 1980 and 1998 were followed up from January 1, 1995 through December 31, 2013, with 9656 having a hospital contact for schizophrenia. Females exposed to prenatal infection had a significantly increased risk of schizophrenia (IRR: 1.61, 95% CI: 1.30-2.00), but not males (IRR: 0.99, 95% CI: 0.77-1.28). Peripubertal trauma was associated with increased risk in both sexes. Males, however, had a significantly higher risk of schizophrenia after exposure to both prenatal infection and peripubertal psychological trauma (IRR: 2.85, 95% CI: 2.32-3.51), with significant interaction between infection and peripubertal trauma on the multiplicative scale (P = .007). Our study demonstrated for the first time that prenatal infection and psychological trauma in peripubertal life can act in synergy to increase the risk of schizophrenia, with a potentially stronger susceptibility in males. © The Author 2016. Published by Oxford University Press on behalf of the Maryland Psychiatric Research Center. All rights reserved. For permissions, please email: journals.permissions@oup.com.

  18. The routine use of prosthetic mesh in austere environments: dogma vs data.

    Science.gov (United States)

    Kuckelman, John P; Barron, Morgan R; Blair, Kelly; Martin, Matthew J

    2016-05-01

    Mesh repair has become the standard in adult hernia repairs. Mesh infection is an uncommon but potentially devastating complication. Currently, there is widespread dogma against the use of prosthetic mesh (PM) in deployed or austere environments but little available data to support or refute this bias. Retrospective review of all hernia repairs over 1 year in a forward deployed surgical unit in Afghanistan. Demographics, hernia type, repair performed, and mesh type were evaluated. Follow-up was completed up to 6 weeks and then as needed for up to a year, and complications to include infection were recorded. Sixty-six patients were identified, mean age was 38 (range 3 to 80) and 98% were male. Single-dose perioperative antibiotics and standard sterile technique were used in all cases. The majority (70%) had PM placed. The mean operative time was 54 min, and mean estimated blood loss was less than 25 cm(3). The vast majority of our hernias were inguinal (95%) with 1 ventral and 2 umbilical hernias. In the PM group, there were no surgical site infections, no mesh infections, and no mesh explantation or reoperation. There were no recurrences in either group identified at up to 1-year postoperation. There was no statistically significant difference in any outcome measure between the PM and no-PM groups. The use of PM for hernia repairs in the austere or forward environment appears safe and did not increase the risk of wound infection, mesh infections, or recurrence. Published by Elsevier Inc.

  19. Coronary artery assessment by multidetector computed tomography in patients with prosthetic heart valves

    International Nuclear Information System (INIS)

    Habets, Jesse; Mali, Willem P.T.M.; Budde, Ricardo P.J.; Brink, Renee B.A. van den; Uijlings, Ruben; Spijkerboer, Anje M.; Chamuleau, Steven A.J.

    2012-01-01

    Patients with prosthetic heart valves may require assessment for coronary artery disease. We assessed whether valve artefacts hamper coronary artery assessment by multidetector CT. ECG-gated or -triggered CT angiograms were selected from our PACS archive based on the presence of prosthetic heart valves. The best systolic and diastolic axial reconstructions were selected for coronary assessment. Each present coronary segment was scored for the presence of valve-related artefacts prohibiting coronary artery assessment. Scoring was performed in consensus by two observers. Eighty-two CT angiograms were performed on a 64-slice (n = 27) or 256-slice (n = 55) multidetector CT. Eighty-nine valves and five annuloplasty rings were present. Forty-three out of 1160 (3.7%) present coronary artery segments were non-diagnostic due to valve artefacts (14/82 patients). Valve artefacts were located in right coronary artery (15/43; 35%), left anterior descending artery (2/43; 5%), circumflex artery (14/43; 32%) and marginal obtuse (12/43; 28%) segments. All cobalt-chrome containing valves caused artefacts prohibiting coronary assessment. Biological and titanium-containing valves did not cause artefacts except for three specific valve types. Most commonly implanted prosthetic heart valves do not hamper coronary assessment on multidetector CT. Cobalt-chrome containing prosthetic heart valves preclude complete coronary artery assessment because of severe valve artefacts. circle Most commonly implanted prosthetic heart valves do not hamper coronary artery assessment circle Prosthetic heart valve composition determines the occurrence of prosthetic heart valve-related artefacts circle Bjoerk-Shiley and Sorin tilting disc valves preclude diagnostic coronary artery segment assessment. (orig.)

  20. Evaluation of 3D printed anatomically scalable transfemoral prosthetic knee.

    Science.gov (United States)

    Ramakrishnan, Tyagi; Schlafly, Millicent; Reed, Kyle B

    2017-07-01

    This case study compares a transfemoral amputee's gait while using the existing Ossur Total Knee 2000 and our novel 3D printed anatomically scalable transfemoral prosthetic knee. The anatomically scalable transfemoral prosthetic knee is 3D printed out of a carbon-fiber and nylon composite that has a gear-mesh coupling with a hard-stop weight-actuated locking mechanism aided by a cross-linked four-bar spring mechanism. This design can be scaled using anatomical dimensions of a human femur and tibia to have a unique fit for each user. The transfemoral amputee who was tested is high functioning and walked on the Computer Assisted Rehabilitation Environment (CAREN) at a self-selected pace. The motion capture and force data that was collected showed that there were distinct differences in the gait dynamics. The data was used to perform the Combined Gait Asymmetry Metric (CGAM), where the scores revealed that the overall asymmetry of the gait on the Ossur Total Knee was more asymmetric than the anatomically scalable transfemoral prosthetic knee. The anatomically scalable transfemoral prosthetic knee had higher peak knee flexion that caused a large step time asymmetry. This made walking on the anatomically scalable transfemoral prosthetic knee more strenuous due to the compensatory movements in adapting to the different dynamics. This can be overcome by tuning the cross-linked spring mechanism to emulate the dynamics of the subject better. The subject stated that the knee would be good for daily use and has the potential to be adapted as a running knee.