WorldWideScience

Sample records for prosthetic disc replacement

  1. Significance of angular mismatch between vertebral endplate and prosthetic endplate in lumbar total disc replacement.

    Science.gov (United States)

    Lee, Chong Suh; Chung, Sung Soo; Oh, Sung Kyun; You, Je Wook

    2011-05-01

    A retrospective study. To determine whether angular mismatch between the vertebral endplate and prosthetic endplate during lumbar total disc replacement (L-TDR) affects the radiological and clinical outcomes. A prosthesis anchored to the vertebral body by using a large central keel carries an inherent risk of angular mismatch between the vertebral endplate and prosthetic endplate at a segment with a greater degree of lordosis, such as L5-S1. Theoretically, this angular mismatch can cause several problems, such as segmental hyperlordosis, anterior positioning of the upper prosthesis, posterior prosthetic edge subsidence, decreased range of motion (ROM), and a poor clinical outcome. This study evaluated 64 prosthetic levels of 56 patients who were implanted with L-TDR between June 2002 and February 2006. There were 38 and 26 prosthetic levels at the L4-5 and L5-S1, respectively. The mean follow-up period was 25.6 (12 to 49) months. The angle of mismatch between the lower endplate of the upper vertebral body and the upper prosthetic plate, segmental flexion/extension ROM, segmental lordosis angle at extension, distance from the posterior wall of the vertebral body to the posterior prosthetic edge were measured by obtaining radiographs. Clinically, the Visual Analogue Scale and Oswestry Disability Index were also evaluated. The angular mismatches between the upper vertebra and prosthesis at L4-5 and L5-S1 were 1.6 degree and 5.6 degree, respectively (P body to the posterior edge of the prosthesis in L5-S1 were 6.8 degree (4 to 13), 12.8 degree (8 to 17), and 3.8 mm (1 to 6 mm) in patients with an angular mismatch of 0.05). Angular mismatch was more common in L5-S1 than in L4-5. L-TDR at the most lordotic level, L5-S1, and implantation of an upper prosthesis with a mismatched angle seem to be the causes of a reduced segmental ROM, increased segmental lordosis, and anterior malpositioning of the prosthesis. However, these changes do not affect the clinical outcomes of

  2. Artificial Disc Replacement

    Science.gov (United States)

    ... Spondylolisthesis BLOG FIND A SPECIALIST Treatments Artificial Disc Replacement (ADR) Patient Education Committee Jamie Baisden The disc ... Disc An artificial disc (also called a disc replacement, disc prosthesis or spine arthroplasty device) is a ...

  3. Vascular complications of prosthetic inter-vertebral discs

    OpenAIRE

    Daly, Kevin J.; Ross, E. Raymond S.; Norris, Heather; McCollum, Charles N.

    2006-01-01

    Five consecutive cases of prosthetic inter-vertebral disc displacement with severe vascular complications on revisional surgery are described. The objective of this case report is to warn spinal surgeons that major vascular complications are likely with anterior displacement of inter-vertebral discs. We have not been able to find a previous report on vascular complications associated with anterior displacement of prosthetic inter-vertebral discs. In all five patients the prosthetic disc had e...

  4. Material Science in Cervical Total Disc Replacement

    Science.gov (United States)

    Pham, Martin H.; Mehta, Vivek A.; Tuchman, Alexander; Hsieh, Patrick C.

    2015-01-01

    Current cervical total disc replacement (TDR) designs incorporate a variety of different biomaterials including polyethylene, stainless steel, titanium (Ti), and cobalt-chrome (CoCr). These materials are most important in their utilization as bearing surfaces which allow for articular motion at the disc space. Long-term biological effects of implanted materials include wear debris, host inflammatory immune reactions, and osteolysis resulting in implant failure. We review here the most common materials used in cervical TDR prosthetic devices, examine their bearing surfaces, describe the construction of the seven current cervical TDR devices that are approved for use in the United States, and discuss known adverse biological effects associated with long-term implantation of these materials. It is important to appreciate and understand the variety of biomaterials available in the design and construction of these prosthetics and the considerations which guide their implementation. PMID:26523281

  5. Material Science in Cervical Total Disc Replacement

    Directory of Open Access Journals (Sweden)

    Martin H. Pham

    2015-01-01

    Full Text Available Current cervical total disc replacement (TDR designs incorporate a variety of different biomaterials including polyethylene, stainless steel, titanium (Ti, and cobalt-chrome (CoCr. These materials are most important in their utilization as bearing surfaces which allow for articular motion at the disc space. Long-term biological effects of implanted materials include wear debris, host inflammatory immune reactions, and osteolysis resulting in implant failure. We review here the most common materials used in cervical TDR prosthetic devices, examine their bearing surfaces, describe the construction of the seven current cervical TDR devices that are approved for use in the United States, and discuss known adverse biological effects associated with long-term implantation of these materials. It is important to appreciate and understand the variety of biomaterials available in the design and construction of these prosthetics and the considerations which guide their implementation.

  6. Material Science in Cervical Total Disc Replacement.

    Science.gov (United States)

    Pham, Martin H; Mehta, Vivek A; Tuchman, Alexander; Hsieh, Patrick C

    2015-01-01

    Current cervical total disc replacement (TDR) designs incorporate a variety of different biomaterials including polyethylene, stainless steel, titanium (Ti), and cobalt-chrome (CoCr). These materials are most important in their utilization as bearing surfaces which allow for articular motion at the disc space. Long-term biological effects of implanted materials include wear debris, host inflammatory immune reactions, and osteolysis resulting in implant failure. We review here the most common materials used in cervical TDR prosthetic devices, examine their bearing surfaces, describe the construction of the seven current cervical TDR devices that are approved for use in the United States, and discuss known adverse biological effects associated with long-term implantation of these materials. It is important to appreciate and understand the variety of biomaterials available in the design and construction of these prosthetics and the considerations which guide their implementation.

  7. Vascular complications of prosthetic inter-vertebral discs.

    Science.gov (United States)

    Daly, Kevin J; Ross, E Raymond S; Norris, Heather; McCollum, Charles N

    2006-10-01

    Five consecutive cases of prosthetic inter-vertebral disc displacement with severe vascular complications on revisional surgery are described. The objective of this case report is to warn spinal surgeons that major vascular complications are likely with anterior displacement of inter-vertebral discs. We have not been able to find a previous report on vascular complications associated with anterior displacement of prosthetic inter-vertebral discs. In all five patients the prosthetic disc had eroded into the bifurcation of the inferior vena cava and the left common iliac vein. In three cases the aortic bifurcation was also involved. The fibrosis was so severe that dissecting out the arteries and veins to provide access to the relevant disc proved impossible. Formal division of the left common iliac vein and artery with subsequent repair was our solution. Anterior inter-vertebral disc displacement was associated with severe vascular injury. Preventing anterior disc displacement is essential in disc design. In the event of anterior displacement, disc removal should be planned with a Vascular Surgeon.

  8. Pregnancy after Prosthetic Aortic Valve Replacement: How Do We Monitor Prosthetic Valvular Function during Pregnancy?

    Directory of Open Access Journals (Sweden)

    Nicole Sahasrabudhe

    2018-01-01

    Full Text Available Background. With modern medicine, many women after structural heart repair are deciding to experience pregnancy. There is a need for further study to identify normal echocardiographic parameters to better assess prosthetic valvular function in pregnancy. In addition, a multidisciplinary approach is essential in managing pregnant patients with complex cardiac conditions. Case. A 22-year-old nulliparous woman with an aortic valve replacement 18 months prior to her pregnancy presented to prenatal care at 20-week gestation. During her prenatal care, serial echocardiography showed a significant increase in the mean gradient across the prosthetic aortic valve. Multidisciplinary management and a serial echocardiography played an integral role in her care that resulted in a successful spontaneous vaginal delivery without complications. Conclusion. Further characterization of the normal echocardiographic parameters in pregnant patients with prosthetic valves is critical to optimize prenatal care for this patient population. This case report is novel in that serial echocardiograms were obtained throughout prenatal care, which showed significant changes across the prosthetic aortic valve. Teaching Points. (1 Further study is needed to identify normal echocardiographic parameters to best assess prosthetic valvular function in pregnancy. (2 Multidisciplinary management is encouraged to optimize prenatal care for women with prosthetic aortic valve replacements.

  9. Spine imaging after lumbar disc replacement: pitfalls and current recommendations

    OpenAIRE

    Robinson, Yohan; Sand?n, Bengt

    2009-01-01

    Abstract Background Most lumbar artificial discs are still composed of stainless steel alloys, which prevents adequate postoperative diagnostic imaging of the operated region when using magnetic resonance imaging (MRI). Thus patients with postoperative radicular symptoms or claudication after stainless steel implants often require alternative diagnostic procedures. Methods Possible complications of lumbar total disc replacement (TDR) are reviewed from the available literature and imaging reco...

  10. Prosthetic replacement of the infrahepatic inferior vena cava for leiomyosarcoma.

    Science.gov (United States)

    Illuminati, Giulio; Calio', Francesco G; D'Urso, Antonio; Giacobbi, Daniela; Papaspyropoulos, Vassilios; Ceccanei, Gianluca

    2006-09-01

    Resection of the infrahepatic inferior vena cava associated with prosthetic graft replacement for caval leiomyosarcoma is an acceptable procedure to obtain prolonged and good-quality survival. A consecutive sample clinical study with a mean follow-up of 40 months. The surgical department of an academic tertiary center and an affiliated secondary care center. Eleven patients, with a mean age of 51 years, who have primary leiomyosarcoma of the infrahepatic inferior vena cava. All of the patients underwent radical resection of the tumor en bloc with the affected segment of the vena cava. Reconstruction consisted of 10 cavocaval polytetrafluoroethylene grafts and 1 cavobiliac graft. An associated right nephrectomy was performed in 2 cases. The left renal vein was reimplanted in the graft in 3 cases. Cumulative disease-specific survival, disease-free survival, and graft patency rates expressed by standard life-table analysis. No patients died in the postoperative period. The cumulative (SE) disease-specific survival rate was 53% (21%) at 5 years. The cumulative (SE) disease-free survival rate was 44% (19%) at 5 years. The cumulative (SE) graft patency rate was 67% (22%) at 5 years. Radical resection followed by prosthetic graft reconstruction is a valuable method for treating primary leiomyosarcoma of the infrahepatic inferior vena cava.

  11. Association of facet tropism and progressive facet arthrosis after lumbar total disc replacement using ProDisc-L.

    Science.gov (United States)

    Shin, Myung-Hoon; Ryu, Kyeong-Sik; Hur, Jung-Woo; Kim, Jin-Sung; Park, Chun-Kun

    2013-08-01

    The purpose of this retrospective study was to examine the association of facet tropism and progressive facet arthrosis (PFA) after lumbar total disc replacement (TDR) surgery using ProDisc-L. A total of 51 segments of 42 patients who had undergone lumbar TDR using ProDisc-L between October 2003 and July 2007 and completed minimum 36-month follow-up period were retrospectively reviewed. The changes of facet arthrosis were categorized as non-PFA and PFA group. Comparison between non-PFA and PFA group was made according to age, sex, mean follow-up duration, grade of preoperative facet arthrosis, coronal and sagittal prosthetic position and degree of facet tropism. Multiple logistic regression analysis was also performed to analyze the effect of facet tropism on the progression of facet arthrosis. The mean age at the surgery was 44.43 ± 11.09 years and there were 16 males and 26 females. The mean follow-up period was 53.18 ± 15.79 months. Non-PFA group was composed of 19 levels and PFA group was composed of 32 levels. Age at surgery, sex proportion, mean follow-up period, level of implant, grade of preoperative facet arthrosis and coronal and sagittal prosthetic position were not significantly different between two groups (p = 0.264, 0.433, 0.527, 0.232, 0.926, 0.849 and 0.369, respectively). However, PFA group showed significantly higher degree of facet tropism (7.37 ± 6.46°) than that of non-PFA group (3.51 ± 3.53°) and p value was 0.008. After adjustment for age, sex and coronal and sagittal prosthetic position, multiple logistic regression analysis revealed that facet tropism of more than 5° was the only significant independent predictor of progression of facet arthrosis (odds ratio 5.39, 95 % confidence interval 1.251-19.343, p = 0.023). The data demonstrate that significant higher degree of facet tropism was seen in PFA group compared with non-PFA group and facet tropism of more than 5° had a significant association with PFA after TDR using ProDisc-L.

  12. Heart valve replacement with the Sorin tilting-disc prosthesis. A 10-year experience.

    Science.gov (United States)

    Milano, A; Bortolotti, U; Mazzucco, A; Mossuto, E; Testolin, L; Thiene, G; Gallucci, V

    1992-02-01

    From 1978 to 1988, 697 patients with a mean age of 48 +/- 11 years (range 5 to 75 years) received a Sorin tilting-disc prosthesis; 358 had had aortic valve replacement, 247 mitral valve replacement, and 92 mitral and aortic valve replacement. Operative mortality rates were 7.8%, 11.3%, and 10.8%, respectively, in the three groups. Cumulative duration of follow-up is 1650 patient-years for aortic valve replacement (maximum follow-up 11.4 years), 963 patient-years for mitral valve replacement (maximum follow-up 9.9 years) and 328 patient-years for mitral and aortic valve replacement (maximum follow-up 9.4 years). Actuarial survival at 9 years is 72% +/- 4% after mitral valve replacement, 70% +/- 3% after aortic valve replacement, and 50% +/- 12% after mitral and aortic valve replacement, and actuarial freedom from valve-related deaths is 97% +/- 2% after mitral valve replacement, 92% +/- 2% after aortic valve replacement, and 62% +/- 15% after mitral and aortic valve replacement. Thromboembolic events occurred in 21 patients with aortic valve replacement (1.3% +/- 0.2%/pt-yr), in 12 with mitral valve replacement (1.2% +/- 0.3% pt-yr), and in seven with mitral and aortic valve replacement (2.1% +/- 0.8%), with one case of prosthetic thrombosis in each group; actuarial freedom from thromboembolism at 9 years is 92% +/- 3% after mitral valve replacement, 91% +/- 3% after aortic valve replacement, and 74% +/- 16% after mitral and aortic valve replacement. Anticoagulant-related hemorrhage was observed in 15 patients after aortic valve replacement (0.9% +/- 0.2%/pt-yr), in 9 after mitral valve replacement (0.9% +/- 0.3%/pt-yr), and in 6 with mitral and aortic valve replacement (0.9% +/- 0.5%/pt-yr); actuarial freedom from this complication at 9 years is 94% +/- 2% after aortic valve replacement, 91% +/- 4% after mitral valve replacement, and 68% +/- 16% after mitral and aortic valve replacement. Actuarial freedom from reoperation at 9 years is 97% +/- 2% after mitral and

  13. Adjacent level effects of bi level disc replacement, bi level fusion and disc replacement plus fusion in cervical spine--a finite element based study.

    Science.gov (United States)

    Faizan, Ahmad; Goel, Vijay K; Biyani, Ashok; Garfin, Steven R; Bono, Christopher M

    2012-03-01

    Studies delineating the adjacent level effect of single level disc replacement systems have been reported in literature. The aim of this study was to compare the adjacent level biomechanics of bi-level disc replacement, bi-level fusion and a construct having adjoining level disc replacement and fusion system. In total, biomechanics of four models- intact, bi level disc replacement, bi level fusion and fusion plus disc replacement at adjoining levels- was studied to gain insight into the effects of various instrumentation systems on cranial and caudal adjacent levels using finite element analysis (73.6N+varying moment). The bi-level fusion models are more than twice as stiff as compared to the intact model during flexion-extension, lateral bending and axial rotation. Bi-level disc replacement model required moments lower than intact model (1.5Nm). Fusion plus disc replacement model required moment 10-25% more than intact model, except in extension. Adjacent level motions, facet loads and endplate stresses increased substantially in the bi-level fusion model. On the other hand, adjacent level motions, facet loads and endplate stresses were similar to intact for the bi-level disc replacement model. For the fusion plus disc replacement model, adjacent level motions, facet loads and endplate stresses were closer to intact model rather than the bi-level fusion model, except in extension. Based on our finite element analysis, fusion plus disc replacement procedure has less severe biomechanical effects on adjacent levels when compared to bi-level fusion procedure. Bi-level disc replacement procedure did not have any adverse mechanical effects on adjacent levels. Copyright © 2011 Elsevier Ltd. All rights reserved.

  14. Total disc replacement using tissue-engineered intervertebral discs in the canine cervical spine.

    Directory of Open Access Journals (Sweden)

    Yu Moriguchi

    Full Text Available The most common reason that adults in the United States see their physician is lower back or neck pain secondary to degenerative disc disease. To date, approaches to treat degenerative disc disease are confined to purely mechanical devices designed to either eliminate or enable flexibility of the diseased motion segment. Tissue engineered intervertebral discs (TE-IVDs have been proposed as an alternative approach and have shown promise in replacing native IVD in the rodent tail spine. Here we demonstrate the efficacy of our TE-IVDs in the canine cervical spine. TE-IVD components were constructed using adult canine annulus fibrosis and nucleus pulposus cells seeded into collagen and alginate hydrogels, respectively. Seeded gels were formed into a single disc unit using molds designed from the geometry of the canine spine. Skeletally mature beagles underwent discectomy with whole IVD resection at levels between C3/4 and C6/7, and were then divided into two groups that received only discectomy or discectomy followed by implantation of TE-IVD. Stably implanted TE-IVDs demonstrated significant retention of disc height and physiological hydration compared to discectomy control. Both 4-week and 16-week histological assessments demonstrated chondrocytic cells surrounded by proteoglycan-rich matrices in the NP and by fibrocartilaginous matrices in the AF portions of implanted TE-IVDs. Integration into host tissue was confirmed over 16 weeks without any signs of immune reaction. Despite the significant biomechanical demands of the beagle cervical spine, our stably implanted TE-IVDs maintained their position, structure and hydration as well as disc height over 16 weeks in vivo.

  15. Recurrent pannus formation causing prosthetic aortic valve dysfunction: Is excision without valve re-replacement applicable?

    Directory of Open Access Journals (Sweden)

    Darwazah Ahmad K

    2012-06-01

    Full Text Available Abstract Prosthetic valve dysfunction at aortic position is commonly caused by pannus formation. The exact etiology is not known. It arises from ventricular aspect of the prosthesis encroaching its leaflets causing stenosis or it may remain localized causing left ventricular outflow tract obstruction without affecting valve function. The difference in location entails different approaches in management. Such a pathology requires surgical excision of the pannus with or without valve re-replacement. A recurrent pannus was observed in a female patient who needed repeated surgical intervention to excise a localized pannus without re-replacement of a well functioning prosthetic valve. Management of our case presents several questions, whether recurrence of pannus is caused by sparing the prosthetic valve, is it simply an exaggeration of an inflammatory healing process in certain individuals or is it ideal to re-replace the valve despite a well preserved function.

  16. Recurrent pannus formation causing prosthetic aortic valve dysfunction: is excision without valve re-replacement applicable?

    Science.gov (United States)

    Darwazah, Ahmad K

    2012-06-29

    Prosthetic valve dysfunction at aortic position is commonly caused by pannus formation. The exact etiology is not known. It arises from ventricular aspect of the prosthesis encroaching its leaflets causing stenosis or it may remain localized causing left ventricular outflow tract obstruction without affecting valve function.The difference in location entails different approaches in management. Such a pathology requires surgical excision of the pannus with or without valve re-replacement.A recurrent pannus was observed in a female patient who needed repeated surgical intervention to excise a localized pannus without re-replacement of a well functioning prosthetic valve.Management of our case presents several questions, whether recurrence of pannus is caused by sparing the prosthetic valve, is it simply an exaggeration of an inflammatory healing process in certain individuals or is it ideal to re-replace the valve despite a well preserved function.

  17. Effect of total lumbar disc replacement on lumbosacral lordosis.

    Science.gov (United States)

    Kasliwal, Manish K; Deutsch, Harel

    2012-10-01

    Original article : To study effect of lumbar disc replacement on lumbosacral lordosis. There has been a growing interest in total disc replacement (TDR) for back pain with the rising concern of adjacent segment degeneration. Lumbar fusion surgery has been shown to lead to decrease in lumbar lordosis, which may account for postfusion pain resulting in less acceptable clinical outcome after successful fusion. TDR has recently emerged as an alternative treatment for back pain. There have been very few studies reporting lumbar sagittal outcome after TDR. Retrospective study of radiographic data of 17 patients who underwent TDR for single level degenerative disc disease at the author's institution was carried out. Study included measurement of preoperative and postoperative segmental and global lumbar lordosis and angle of lordosis. Patients age varied from 19 to 54 (mean, 35) years. Follow-up ranged from 12 to 24 months. TDR was performed at L4-5 level in 3 patients and L5-S1 level in 14 patients. The average values for segmental lordosis, global lordosis, and angle of lordosis at the operated level before and after surgery were 17.3, 49.7, and 8.6 degrees and 21.6, 54, and 9.5 degrees, respectively. There was a trend toward significant (P=0.02) and near significant (P=0.057) increase in segmental and global lordosis, respectively after TDR. Although prosthesis increased angle of lordosis at the level implanted in majority of the patients, the difference in preoperative and postoperative angle of lordosis was not significant (P=0.438). In addition, there was no correlation between the angle of implant of chosen and postoperative angle of lordosis at the operated level. The effect of TDR on sagittal balance appears favorable with an increase in global and segmental lumbar lordosis after single level TDR for degenerative disc disease. The degree of postoperative angle of lordosis was not affected by the angle of implant chosen at the operated level and varied

  18. Spine imaging after lumbar disc replacement: pitfalls and current recommendations

    Directory of Open Access Journals (Sweden)

    Sandén Bengt

    2009-07-01

    Full Text Available Abstract Background Most lumbar artificial discs are still composed of stainless steel alloys, which prevents adequate postoperative diagnostic imaging of the operated region when using magnetic resonance imaging (MRI. Thus patients with postoperative radicular symptoms or claudication after stainless steel implants often require alternative diagnostic procedures. Methods Possible complications of lumbar total disc replacement (TDR are reviewed from the available literature and imaging recommendations given with regard to implant type. Two illustrative cases are presented in figures. Results Access-related complications, infections, implant wear, loosening or fracture, polyethylene inlay dislodgement, facet joint hypertrophy, central stenosis, and ankylosis of the operated segment can be visualised both in titanium and stainless steel implants, but require different imaging modalities due to magnetic artifacts in MRI. Conclusion Alternative radiographic procedures should be considered when evaluating patients following TDR. Postoperative complications following lumbar TDR including spinal stenosis causing radiculopathy and implant loosening can be visualised by myelography and radionucleotide techniques as an adjunct to plain film radiographs. Even in the presence of massive stainless steel TDR implants lumbar radicular stenosis and implant loosening can be visualised if myelography and radionuclide techniques are applied.

  19. Orthodontic Space Closure Versus Prosthetic Replacement of Missing Upper Lateral Incisors in Patients With Bilateral Cleft Lip and Palate

    NARCIS (Netherlands)

    Oosterkamp, Barbara C. M.; Dijkstra, Pieter U.; Remmelink, Hendrik J.; van Oort, Robert P.; Sandham, John

    2010-01-01

    Objective To compare dental aesthetics and function of orthodontic space closure versus prosthetic replacement of upper lateral incisors in patients with bilateral cleft lip and palate The predominant mode of prosthetic replacement was resin-bonded bridges Patients and Methods The retrospective

  20. [Prosthetic replacement of missing teeth. Indications for fixed and removable dental prostheses

    NARCIS (Netherlands)

    Witter, D.J.; Gerritsen, A.E.; Baat, C. de; Creugers, N.H.J.

    2014-01-01

    Prosthetic replacement of missing teeth aims to improve health. This can be achieved by improving the patient's well-being and quality of life and by restoring the biological balance in terms ofocclusal and mandibular stability in the occlusal and the orofacial system. In occlusal systems with a

  1. Prosthetic valve sparing aortic root replacement: an improved technique.

    Science.gov (United States)

    Leacche, Marzia; Balaguer, Jorge M; Umakanthan, Ramanan; Byrne, John G

    2008-10-01

    We describe a modified surgical technique to treat patients with a previous history of isolated aortic valve replacement who now require aortic root replacement for an aneurysmal or dissected aorta. This technique consists of replacing the aortic root with a Dacron conduit, leaving intact the previously implanted prosthesis, and re-implanting the coronary arteries in the Dacron graft. Our technique differs from other techniques in that we do not leave behind any aortic tissue remnant and also in that we use a felt strip to obliterate any gap between the old sewing ring and the newly implanted graft. In our opinion, this promotes better hemostasis. We demonstrate that this technique is safe, feasible, and results in acceptable outcomes.

  2. Orthodontic space closure versus prosthetic replacement of missing upper lateral incisors in patients with bilateral cleft lip and palate.

    Science.gov (United States)

    Oosterkamp, Barbara C M; Dijkstra, Pieter U; Remmelink, Hendrik J; van Oort, Robert P; Sandham, Andrew

    2010-11-01

    To compare dental aesthetics and function of orthodontic space closure versus prosthetic replacement of upper lateral incisors in patients with bilateral cleft lip and palate. The predominant mode of prosthetic replacement was resin-bonded bridges. The retrospective study group consisted of 17 patients treated with orthodontic space closure (13 men, four women; median age, 27.1 years; interquartile range, 20.6 to 33.3 years) and 10 patients treated with prosthetic replacement (five men, five women; median age, 27.7 years; interquartile range, 20.9 to 39.7 years). Dental aesthetics were evaluated by the patients and by a professional panel. Mandibular function was evaluated by means of the mandibular function impairment questionnaire. The level of mandibular impairment was calculated using the Function Impairment Rating Scale. With respect to dental aesthetics, no significant differences between patients treated with orthodontic space closure and prosthetic replacement were found. With respect to function, the level of mandibular impairment was significantly higher in patients treated with prosthetic replacement compared with patients treated with orthodontic space closure, as indicated by high scores on specific masticatory functions. Orthodontic space closure and prosthetic replacement in bilateral cleft lip and palate patients produce similar results in terms of aesthetics. In terms of function, prosthetic replacement results in significantly more impairment of specific masticatory functions.

  3. Single-tooth replacement: factors affecting different prosthetic treatment modalities

    Directory of Open Access Journals (Sweden)

    Al-Quran Firas A

    2011-12-01

    Full Text Available Abstract Background The choice between several treatment options for replacing a single missing tooth is influenced by clinical, dentist- and patient-immanent factors. This study aimed to determine the patient factors that would affect the treatment decision to replace a single missing tooth and to assess the satisfaction with several options. Method 200 volunteers involved (121 females and 79 males divided into four groups, Group A: consisted of patients with conventional fixed partial dentures or patients with resin bonded fixed partial dentures. Group B: consisted of patients who received removable partial dentures while Group C: consisted of patients who received a single implant supported crown, and a control group D: consisted of patients who received no treatment. Data were collected using a questionnaire. Results The highest percentage of males within groups (58% was within the removable prostheses category. The majority of the subjects in the study reported that the main reason for replacing a missing tooth was for esthetic and function. Most important factor affecting the choice between treatment modalities was damaging the neighboring teeth. Pain, post operative sensitivity and dental phobia were important factors in choosing the prosthesis type and affected the control group patients not to have any treatment. The highest satisfaction percentage among groups studied was recorded for dental implants then FPD groups, while the least percentage were in both the control and RPD groups, for all aspects of function, esthetic and speech efficiency. Conclusions The final choice between FPD, RPD and implant depended on several factors which affected the decision making; among these is cost and patients' awareness of the different treatment options.

  4. Comparative study of radiography and scintigraphy for loosening and infection of prosthetic hip replacement

    Energy Technology Data Exchange (ETDEWEB)

    Park, Mi Sook; Lee, Sun Wha; Choi, Woo Suk; Lim, Joo Won; Song, Han Joon; Ahn, Chi Yul [College of Medicine, Kyung Hee University, Seoul (Korea, Republic of)

    1987-10-15

    Prosthetic hip replacement is associated with certain complications which result in a painful hip. Many of these, e. g. prosthetic dislocation, fracture, trochanteric avulsion, and heterotopic calcification are easily diagnosed by conventional radiography. However, radiographic evaluation for infection and/pr loosening of prosthesis as major complications requiring reoperation often contributes little to the resolution of the diagnostic problem. The authors made a comparative study of plain radiography and scintigraphy of 39 cases performed revision at Kyung Hee University Hospital from Sep. '81-to Aug. '86. The results were as follows: 1. In 39 revised prosthetic hip replacement, 26 cases (67%) of loosening without infection and 11 cases (28%) of infection were proven. 2. In loosening of prosthesis, plain radiography showed true positive rate of 76% and true negative rate of 60%, and scintigraphy showed true positive rate of 75% and true negative rate of 95%. 3. In infection of prosthesis, plain radiography revealed true positive rate of 55% and true negative rate of 96%, and scintigraphy revealed true positive rate of 100% and true negative rate of 83%. 4. Scintigraphy and plain radiography were useful as complementary procedure in evaluating and differentiating loosening and/or infection of prosthetic component.

  5. Comparative study of radiography and scintigraphy for loosening and infection of prosthetic hip replacement

    International Nuclear Information System (INIS)

    Park, Mi Sook; Lee, Sun Wha; Choi, Woo Suk; Lim, Joo Won; Song, Han Joon; Ahn, Chi Yul

    1987-01-01

    Prosthetic hip replacement is associated with certain complications which result in a painful hip. Many of these, e. g. prosthetic dislocation, fracture, trochanteric avulsion, and heterotopic calcification are easily diagnosed by conventional radiography. However, radiographic evaluation for infection and/pr loosening of prosthesis as major complications requiring reoperation often contributes little to the resolution of the diagnostic problem. The authors made a comparative study of plain radiography and scintigraphy of 39 cases performed revision at Kyung Hee University Hospital from Sep. '81-to Aug. '86. The results were as follows: 1. In 39 revised prosthetic hip replacement, 26 cases (67%) of loosening without infection and 11 cases (28%) of infection were proven. 2. In loosening of prosthesis, plain radiography showed true positive rate of 76% and true negative rate of 60%, and scintigraphy showed true positive rate of 75% and true negative rate of 95%. 3. In infection of prosthesis, plain radiography revealed true positive rate of 55% and true negative rate of 96%, and scintigraphy revealed true positive rate of 100% and true negative rate of 83%. 4. Scintigraphy and plain radiography were useful as complementary procedure in evaluating and differentiating loosening and/or infection of prosthetic component

  6. Recurrent pannus formation causing prosthetic aortic valve dysfunction: Is excision without valve re-replacement applicable?

    OpenAIRE

    Darwazah Ahmad K

    2012-01-01

    Abstract Prosthetic valve dysfunction at aortic position is commonly caused by pannus formation. The exact etiology is not known. It arises from ventricular aspect of the prosthesis encroaching its leaflets causing stenosis or it may remain localized causing left ventricular outflow tract obstruction without affecting valve function. The difference in location entails different approaches in management. Such a pathology requires surgical excision of the pannus with or without valve re-replace...

  7. [Late outlet strut fracture of an aortic Björk-Shiley and embolization of the prosthetic disc].

    Science.gov (United States)

    Brochet, E; Bougis de Brux, M A; Assayag, P; Benacin, Y; Gamerman, G; Guerot, C; Valère, P E

    1988-09-01

    A new case of late fracture of an outlet strut in a convexo-concave Björk-Shiley valve is reported. The fracture occurred 6 years after aortic implantation of the valve and was responsible for aorto-iliac embolization by the prosthetic disc and death of the patient from cardiogenic shock. This not uncommon complication of the Björk-Shiley valve prosthesis is usually ascribed to the relative fragility of its outlet strut welded to the metallic ring and subjected to strong pressures. Although most cases were observed within the first two years of prosthetic valve insertion, and mainly with valves manufactured in 1981 and 1982, our case and a few others demonstrate the possibility of late rupture. Cardiologists must be aware of this possible complication, since in some favourable cases it can be diagnosed at an early stage and the patient's life can be saved by an emergency operation.

  8. Aortic valve insufficiency in the teenager and young adult: the role of prosthetic valve replacement.

    Science.gov (United States)

    Bradley, Scott M

    2013-10-01

    The contents of this article were presented in the session "Aortic insufficiency in the teenager" at the congenital parallel symposium of the 2013 Society of Thoracic Surgeons (STS) annual meeting. The accompanying articles detail the approaches of aortic valve repair and the Ross procedure.(1,2) The current article focuses on prosthetic valve replacement. For many young patients requiring aortic valve surgery, either aortic valve repair or a Ross procedure provides a good option. The advantages include avoidance of anticoagulation and potential for growth. In other patients, a prosthetic valve is an appropriate alternative. This article discusses the current state of knowledge regarding mechanical and bioprosthetic valve prostheses and their specific advantages relative to valve repair or a Ross procedure. In current practice, young patients requiring aortic valve surgery frequently undergo valve replacement with a prosthetic valve. In STS adult cardiac database, among patients ≤30 years of age undergoing aortic valve surgery, 34% had placement of a mechanical valve, 51% had placement of a bioprosthetic valve, 9% had aortic valve repair, and 2% had a Ross procedure. In the STS congenital database, among patients 12 to 30 years of age undergoing aortic valve surgery, 21% had placement of a mechanical valve, 18% had placement of a bioprosthetic valve, 30% had aortic valve repair, and 24% had a Ross procedure. In the future, the balance among these options may be altered by design improvements in prosthetic valves, alternatives to warfarin, the development of new patch materials for valve repair, and techniques to avoid Ross autograft failure.

  9. Prosthetic Aortic Valve Fixation Study: 48 Replacement Valves Analyzed Using Digital Pressure Mapping.

    Science.gov (United States)

    Lee, Candice Y; Wong, Joshua K; Ross, Ronald E; Liu, David C; Khabbaz, Kamal R; Martellaro, Angelo J; Gorea, Heather R; Sauer, Jude S; Knight, Peter A

    Prostheses attachment is critical in aortic valve replacement surgery, yet reliable prosthetic security remains a challenge. Accurate techniques to analyze prosthetic fixation pressures may enable the use of fewer sutures while reducing the risk of paravalvular leaks (PVL). Customized digital thin film pressure transducers were sutured between aortic annulus models and 21-mm bioprosthetic valves with 15 × 4-mm, 12 × 4-mm, or 9 × 6-mm-wide pledgeted mattress sutures. Simulating open and minimally invasive access, 4 surgeons, blinded to data acquisition, each secured 12 valves using manual knot-tying (hand-tied [HT] or knot-pusher [KP]) or automated titanium fasteners (TFs). Real-time pressure measurements and times were recorded. Two-dimensional (2D) and 3D pressure maps were generated for all valves. Pressures less than 80 mm Hg were considered at risk for PVL. Pressures under each knot (intrasuture) fell less than 80 mm Hg for 12 of 144 manual knots (5/144 HT, 7/144 KP) versus 0 of 288 TF (P prosthetic valve security.

  10. Telemedicine consulting in the patient preparation and planning of prosthetic tooth replacement

    Directory of Open Access Journals (Sweden)

    Mladenović Dragan

    2013-01-01

    Full Text Available Introduction. In the management of edentulous spaces, there is a permanent need of a dentist-prosthetician in charge to consult other specialists. Modern telemedicine, based on powerful computer and telecomunication systems, offers an adequate answer to these challenges, being able to transfer and obtain clinical data and consultation information over large distances. Using smartphone or a computer, the teleconsultant acces the system, downloads and review the data and photographs and gave suggestions. The system then enables direct, real time contact with the consultant, chat, or directs them to contact each other by phone. Case report. We presented telemedicine consulting in the patient preparation and planning of prosthetic tooth replacement in 3 cases with different teleconsultation requirements: the first case for prosthetic rehabilitation of his upper teeth, the second one for prosthetic management of his partial edentulousness and “a growth on his gums” in the vestibular region of the frontal teeth and the third one for prosthetic management of total edentulousness of her upper jaw. We used the system of telemedicine in dentistry, established at the Faculty of Medicine in Kosovska Mitrovica. The operation was based on the computer application system XPA3 Online, computer networking and mobile smartphone network. All consultations were succefull with no need for further procedures in regional center. Conclusion. The use of a mobile smartphone has brought about the mobility and availability of teleconsultant specialists in an extent never seen before. Prostheticians are thus able to offer better service to their patients and improve the quality of management of partially or totally edentulous patients, especially in rural areas.

  11. Telemedicine consulting in the patient preparation and planning of prosthetic tooth replacement.

    Science.gov (United States)

    Mladenović, Dragan; Tosić, Goran; Zivković, Dusan; Djindjić, Natasa; Mladenović, Lidija; Mladenović, Sanja; Marković, Ivana

    2013-09-01

    In the management of edentulous spaces, there is a permanent need of a dentist-prosthetician in charge to consult other specialists. Modern telemedicine, based on powerful computer and telecomunication systems, offers an adequate answer to these challenges, being able to transfer and obtain clinical data and consultation information over large distances. Using smartphone or a computer, the teleconsultant acces the system, downloads and review the data and photographs and gave suggestions. The system then enables direct, real time contact with the consultant, chat, or directs them to contact each other by phone. We presented telemedicine consulting in the patient preparation and planning of prosthetic tooth replacement in 3 cases with different teleconsultation requirements: the first case for prosthetic rehabilitation of his upper teeth, the second one for prosthetic management of his partial edentulousness and "a growth on his gums" in the vestibular region of the frontal teeth and the third one for prosthetic management of total edentulousness of her upper jaw. We used the system of telemedicine in dentistry, established at the Faculty of Medicine in Kosovska Mitrovica. The operation was based on the computer application system XPA3 Online, computer networking and mobile smartphone network. All consultations were succefull with no need for further procedures in regional center. The use of a mobile smartphone has brought about the mobility and availability of teleconsultant specialists in an extent never seen before. Prostheticians are thus able to offer better service to their patients and improve the quality of management of partially or totally edentulous patients, especially in rural areas.

  12. Infection imaging with 99mTc-biotin in patients with prosthetic hip replacement

    International Nuclear Information System (INIS)

    Villa, G.; Mariani, G.; Augeri, C.; Pipino, F.; Paganelli, G.; Chinol, M.

    2002-01-01

    Full text: Although the incidence of infection in prosthetic hip joint replacements has decreased from about 10-15 % to about 0.5-2 % over the last 20 years, the total number of infections has actually increased because of the large number of patients undergoing the procedure. The most frequent clinical presentation of this complication is functional impairment and pain, with or without fever and other signs and/or symptoms of infection. The main is differentiating true infection from simple loosening with inflammation of the implanted stem. Scintigraphy with radiolabeled autologous leukocytes (WBC) represents the 'gold standard' nuclear medicine procedure for imaging infection. However, this procedure is time-consuming, expensive, and involves some biological hazard. Preliminary data, obtained during validation of the avidin/111In-biotin approach, have suggested some potential of 111ln-biotin per se to accumulate at sites of infection. In this pilot study we explored the potential of 99mTc-biotin as an infection imaging agent in pts with orthopedic infections. N4-lys-biotin was labeled with 1110 MBq. Sixteen pts bearing a total of 20 prosthetic hip replacements were enrolled in the study (9 women and 7 men, mean age 73.2 yrs). Eight pts had previously undergone removal of their hip prosthesis because of infection, while infection was suspected in the remaining 8 pts. Scintigraphy was recorded 20 min, then 1, 4 and 24 hr after the i.v. injection of 99mTc-biotin. Within 48 hrs of the 99mTc-biotin study, all pts also underwent scintigraphy with 99mTc-HMPAO-WBC. Out of the 20 hips evaluated, 15 turned out to be infected while in the remaining 5 cases pain was only caused by bone-prosthetic loosening and/or conditions other than infection. In 12/15 infected sites scintigraphy was concordantly positive with both procedures, 99mTc-biotin yielding higher target-to-nontarget ratios than 99mTc-HMPAO-WBC in 4 cases and similar values in the other cases. Discordant patterns

  13. Comparison of magnetic resonance imaging and Laser Doppler Anemometry velocity measurements downstream of replacement heart valves: implications for in vivo assessment of prosthetic valve function.

    Science.gov (United States)

    Fontaine, A A; Heinrich, R S; Walker, P G; Pedersen, E M; Scheidegger, M B; Boesiger, P; Walton, S P; Yoganathan, A P

    1996-01-01

    The non-invasive, in-vivo assessment of prosthetic valve function is compromised by the lack of accurate measurements of the transvalvular flow fields or hemodynamics by current techniques. Short echo time magnetic resonance imaging (MRI) may provide a method for the non-invasive, in vivo assessment of prosthetic valve function by accurately measuring changes in the transvalvular flow fields associated with normal and dysfunctional prosthetic valves. The objectives of these in vitro experiments were to investigate the potential for using MRI as a tool to measure the complex flow fields distal to replacement heart valves, and to assess the accuracy of MRI velocity measurements by comparison with Laser Doppler Anemometry (LDA), a gold standard. The velocity fields downstream of tilting disc, bileaflet, ball and cage, and pericardial tissue valves were measured using both three-component LDA and MRI phase velocity encoding under a steady flow rate of 22.8 l/min, simulating peak systolic flow. The valves were tested under normal and stenotic conditions to assess the MRI capabilities under a wide range of local flow conditions, velocities and turbulence levels. A new short echo time MRI technique (FAcE), which allowed velocity measurements in stenotic jets with high turbulence, was tested. Good overall agreement was obtained between the MRI velocity measurements and the LDA data. The MRI velocity measurements adequately reproduced the spatial structure of the flow fields. In most cases peak velocities were accurately measured to within 15%. The results indicate that the FAcE MRI method has the potential to be used as a diagnostic tool to assess prosthetic valve function.

  14. An evaluation of information on the Internet of a new device: the lumbar artificial disc replacement.

    Science.gov (United States)

    Garcia, Ryan M; Messerschmitt, Patrick J; Ahn, Nicholas U

    2009-02-01

    An analysis of websites, accessible to the public, was conducted pertaining to the lumbar artificial disc replacement. The objective was to investigate the content of information available on the Internet pertaining to the lumbar artificial disc replacement. The Internet is widely used by patients as an educational tool for health care information. Additionally, the Internet is used as a medium for direct-to-consumer marketing. Recent approval of the lumbar artificial disc replacement has led to the emergence of numerous websites offering information about this procedure. It is thought that patients can be influenced by information found on the Internet; therefore, it is imperative that this information be accurate and as complete as possible. Three commonly used search engines were used to locate 105 (35/search engine) websites providing information about the lumbar artificial disc replacement. Each website was evaluated with regard to authorship and content. Fifty-nine percent of the websites reviewed were authorized by a private physician group, 9% by an academic physician group, 6% by industry, 11% were news reports, and 15% were not otherwise categorized. Seventy-two percent offered a mechanism for direct contact and 30% provided clear patient selection criteria. Benefits were expressed in 87% of websites, whereas associated risks were described in 28% or less. European experiences were noted in 53%, whereas only 22% of websites detailed the current US experience. The results of this study demonstrate that much of the content of Internet-derived information pertaining to the lumbar artificial disc replacement is potentially misleading. Until long-term data are available, patients should be cautioned when using the Internet as a source for health care information, particularly with regard to the lumbar artificial disc replacement.

  15. Prosthetic replacement vs space closure for maxillary lateral incisor agenesis: A systematic review.

    Science.gov (United States)

    Silveira, Giordani Santos; de Almeida, Natália Valli; Pereira, Daniele Masterson Tavares; Mattos, Cláudia Trindade; Mucha, José Nelson

    2016-08-01

    Defining the best treatment for maxillary lateral incisor agenesis is a challenge. Our aim in this study was to determine, with the evidence available in the literature, the best treatment for maxillary lateral incisor agenesis in the permanent dentition, evaluating the esthetic, occlusal (functional), and periodontal results between prosthetic replacement and orthodontic space closure. Electronic databases (CENTRAL, PubMed, Web of Science, Scopus, and LILACS) were searched in September 2014 and updated in January 2015, with no restriction on language or initial date. A manual search of the reference lists of the potential studies was performed. Risk of bias was assessed by the Newcastle Ottawa Scale. The search identified 2174 articles, of which 1196 were excluded because they were duplicates. Titles and abstracts of 978 articles were accessed, and 957 were excluded. In total, 21 articles were read in full, and 9 case-control studies were included after applying the inclusion and exclusion criteria. Data were extracted from the articles selected, and a table was compiled for comparison and analysis of the results. There were no randomization and blinding, and the risk of bias evaluation found gaps in compatibility and outcome domains in almost all selected studies. Tooth-supported dental prostheses of maxillary lateral incisor agenesis had worse scores in the periodontal indexes than did orthodontic space closure. Space closure is evaluated better esthetically than prosthetic replacements, and the presence or absence of a Class I relationship of the canines showed no relationship with occlusal function or with signs and symptoms of temporomandibular disorders. Copyright © 2016 American Association of Orthodontists. Published by Elsevier Inc. All rights reserved.

  16. Wear studies on prosthetic materials using the pin-on-disc machine.

    Science.gov (United States)

    Wright, K W; Dobbs, H S; Scales, J T

    1982-01-01

    The wear of ultra high molecular weight polyethylene in combination with cobalt-chromium-molybdenum alloy was investigated by pin-on-disc experiments in which the alloy pin was loaded against the rotating polyethylene disc. In some experiments the pin was stationary, but in others it rotated about its axis. The effect of lubricant type, pin rotation, magnitude of the applied load, magnitude of the relative surface velocity, and disc storage in various environments was investigated. Wear of the polyethylene was assessed at 100 h intervals by both volumetric and gravimetric methods. Each experiment lasted 1000 h. It was concluded that of the lubricants tested bovine serum was the most suitable and that pin rotation produced more suitable polyethylene surfaces than did the stationary pin. The wear rate increased slightly with load (possibly owing to creep), was insensitive to speed, and was not affected by disc storage. The dynamic coefficient of friction increased with running tme. Results obtained by the two wear assessment methods were comparable and the reproducibility of the results was good.

  17. Difference in occurrence of heterotopic ossification according to prosthesis type in the cervical artificial disc replacement.

    Science.gov (United States)

    Yi, Seong; Kim, Keung Nyun; Yang, Moon Sul; Yang, Joong Won; Kim, Hoon; Ha, Yoon; Yoon, Do Heum; Shin, Hyun Chul

    2010-07-15

    Retrospective study of the difference of heterotopic ossification (HO) occurrence according to 3 different types of prosthesis. This study was designed to investigate the difference of HO occurrence according to different type of prosthesis. HO is defined as formation of the bone outside the skeletal system. Reported HO occurrence rate in cervical artificial disc replacement (ADR) was unexpectedly high and varied. But the influencing factors of HO in cervical ADR have not been elucidated well. The prosthesis-related factors for making difference of HO occurrence were investigated in this study. A total of 170 patients undergoing cervical arthroplasty with the Bryan cervical disc prosthesis (Medtroic Sofamor Danek, Memphis, TN), Mobi-C disc prosthesis (LDR Medical, Troyes, France), and ProDisc-C (Synthes, Inc., West Chester, PA) were included. Cervical lateral radiographs obtained before and after surgery were used to identify HO. Occurrence rate, occurrence-free period, location, and grade of HOs were investigated according to the different prosthesis. Each prosthesis group included patients as follows: Bryan disc, 81 patients; Mobi-C, 61 patients; and ProDisc-C, 28 patients. Overall HO rate was 40.6% (69 of 170 patients). Each HO occurrence rate by prosthesis was as follows: the Bryan disc group, 21.0%; Mobi-C group, 52.5%; and the ProDisc-C group, 71.4%. In the survival analysis, all patients showed 27.1 +/- 3.7 months as the median survival. The Bryan disc group showed statistically longer survival (48.4 +/- 7.4 months) than the other groups. Occurrence of HO is an inevitable postoperative complication after cervical ADR. The occurrence rate of HO was higher than our expectation. Moreover, definite differences in occurrence rate according to the prosthesis type were identified by this study.

  18. An evaluation of information on the internet about a new device: the cervical artificial disc replacement.

    Science.gov (United States)

    Qureshi, Sheeraz A; Koehler, Steven M; Lin, James D; Bird, Justin; Garcia, Ryan M; Hecht, Andrew C

    2012-05-01

    Cross-sectional survey. The objective of this study was to investigate the authorship, content, and quality of information available to the public on the Internet pertaining to the cervical artificial disc replacement device. The Internet is widely used by patients as an educational tool for health care information. In addition, the Internet is used as a medium for direct-to-consumer marketing. Increasing interest in cervical artificial disc replacement has led to the emergence of numerous Web sites offering information about this procedure. It is thought that patients can be influenced by information found on the Internet. A cross section of Web sites accessible to the general public was surveyed. Three commonly used search engines were used to locate 150 (50/search engine) Web sites providing information about the cervical artificial disc replacement. Each Web site was evaluated with regard to authorship and content. Fifty-three percent of the Web sites reviewed were authorized by a private physician group, 4% by an academic physician group, 13% by industry, 16% were news reports, and 14% were not otherwise categorized. Sixty-five percent of Web sites offered a mechanism for direct contact and 19% provided clear patient eligibility criteria. Benefits were expressed in 80% of Web sites, whereas associated risks were described in 35% or less. European experiences were noted in 17% of Web sites, whereas only 9% of Web sites detailed the current US experience. CONCLUSION.: The results of this study demonstrate that much of the content of the Internet-derived information pertaining to the cervical artificial disc replacement is for marketing purposes and may not represent unbiased information. Until we can confirm the content on a Web site to be accurate, patients should be cautioned when using the Internet as a source for health care information related to cervical disc replacement.

  19. Outcomes of Reoperative Valve Replacement in Patients with Prosthetic Valve Endocarditis: A 20-Year Experience

    Directory of Open Access Journals (Sweden)

    Young Woong Kim

    2018-02-01

    Full Text Available Background: Prosthetic valve endocarditis (PVE is a serious complication of cardiac valve replacement, and many p atients with P VE r equire r eoperation. The aim of t his study was to r eview our institutional 2 0 -year experience of surgical reoperative valve replacement in patients with PVE. Methods: A retrospective study was performed on 84 patients (mean age, 54.8±12.7 years; 51 males who were diagnosed with PVE and underwent reoperative valve replacement from January 1995 to December 2016. Results: PVE was found in 1 valve in 61 cases (72.6%, and in 2 or more valves in 23 cases (27.4%. The median follow-up duration was 47.3 months (range, 0 to 250 months. Postoperative complications occurred in 39 patients (46.4%. Reinfection occurred in 6 cases, all within 1 year. The freedom from reinfection rate at 5 years was 91.0%±3.5%. The overall survival rates at 5 and 10 years were 64.4%±5.8% and 54.3%±7.3%, respectively. In stepwise multivariable Cox proportional hazard models, older age (hazard ratio [HR], 1.48; 95% confidence interval [CI], 1.05 to 2.10; p=0.027 and cardiopulmonary bypass (CPB time (HR, 1.03; 95% CI, 1.00 to 1.0 1; p =0 . 0 33 e merged a s independent risk f actors f or d eath. Conclusion: Older age and a longer CPB time were associated with an increased risk of overall mortality in PVE patients.

  20. Design and clinical outcome of a novel 3D-printed prosthetic joint replacement for the human temporomandibular joint.

    Science.gov (United States)

    Ackland, David; Robinson, Dale; Lee, Peter Vee Sin; Dimitroulis, George

    2018-05-11

    Stock prosthetic temporomandibular joint replacements come in limited sizes, and do not always encompass the joint anatomy that presents clinically. The aims of this study were twofold. Firstly, to design a personalized prosthetic total joint replacement for the treatment of a patient's end-stage temporomandibular joint osteoarthritis, to implant the prosthesis into the patient, and assess clinical outcome 12-months post-operatively; and secondly, to evaluate the influence of changes in prosthetic condyle geometry on implant load response during mastication. A 48-year-old female patient with Grade-5 osteoarthritis to the left temporomandibular joint was recruited, and a prosthesis developed to match the native temporomandibular joint anatomy. The prosthesis was 3D printed, sterilized and implanted into the patient, and pain and function measured 12-months post-operatively. The prosthesis load response during a chewing-bite and maximum-force bite was evaluated using a personalized multi-body musculoskeletal model. Simulations were performed after perturbing condyle thickness, neck length and head sphericity. Increases in prosthetic condyle neck length malaligned the mandible and perturbed temporomandibular joint force. Changes in condylar component thickness greatly influenced fixation screw stress response, while a more eccentric condylar head increased prosthetic joint-contact loading. Post-operatively, the prosthetic temporomandibular joint surgery reduced patient pain from 7/10 to 1/10 on a visual analog scale, and increased intercisal opening distance from 22 mm to 38 mm. This study demonstrates effectiveness of a personalized prosthesis that may ultimately be adapted to treat a wide-range of end-stage temporomandibular joint conditions, and highlights sensitivity of prosthesis load response to changes in condylar geometry. Copyright © 2018 Elsevier Ltd. All rights reserved.

  1. International normalized ratio self-management lowers the risk of thromboembolic events after prosthetic heart valve replacement.

    Science.gov (United States)

    Eitz, Thomas; Schenk, Soren; Fritzsche, Dirk; Bairaktaris, Andreas; Wagner, Otto; Koertke, Heinrich; Koerfer, Reiner

    2008-03-01

    Although prosthetic valves are durable and easy to implant, the need for lifetime warfarin-based anticoagulation restricts their exclusive usage. We investigated if anticoagulation self-management improves outcome in a single-center series. Between 1994 and 1998, 765 patients with prosthetic valve replacements were prospectively enrolled and randomized to receive conventional anticoagulation management by their primary physician (group 1, n = 295) or to pursue anticoagulation self-management (group 2, n = 470). A study head office was implemented to coordinate and monitor anticoagulation protocols, international normalized ratios (INR), and adverse events. Patients were instructed on how to obtain and test their own blood samples and to adjust warfarin dosages according to the measured INR (target range, 2.5 to 4). Mean INR values were slightly yet significantly smaller in group 1 than in group 2 (2.8 +/- 0.7 vs 3.0 +/- .6, p events were similar in both groups. Time-related multivariate analysis identified INR self-management and higher INR as independent predictors for better outcome. Anticoagulation self-management can improve INR profiles up to 2 years after prosthetic valve replacement and reduce adverse events. Current indications of prosthetic rather than biologic valve implantations may be extended if the benefit of INR self-management is shown by future studies with longer follow-up.

  2. Research Regarding the Manufacturing through AM Technologies of an Implant for Cervical Disc Replacement

    Directory of Open Access Journals (Sweden)

    Miron-Borzan Cristina Stefana

    2017-01-01

    Full Text Available Worldwide, accidents are one of the main causes of illness in developed and undeveloped socio-economic countries. Additive Manufacturing (AM technologies bring extremely useful and advantageous applications for the new neurosurgical procedures. Because the surgical insertion of devices for cervical disc replacement is very difficult, the development of new devices that can minimize these disadvantages, are needed. The aim of this paper was to improve the characteristics of an implant for cervical intervertebral disc replacement, a model based on an existing implant. A cervical cage designed for stabilization and arthrodesis between the cervical vertebrae was analyzed. A new design of a cage that have some improvements, useful for patient safety, as well as for facilitating the surgery was developed. The new proposed design was verified through Fine Element Analysis.

  3. Lean Six Sigma: a new approach to the management of patients undergoing prosthetic hip replacement surgery.

    Science.gov (United States)

    Improta, Giovanni; Balato, Giovanni; Romano, Maria; Carpentieri, Francesco; Bifulco, Paolo; Alessandro Russo, Mario; Rosa, Donato; Triassi, Maria; Cesarelli, Mario

    2015-08-01

    In 2012, health care spending in Italy reached €114.5 billion, accounting for 7.2% of the Gross Domestic Product (GDP) and 14.2% of total public spending. Therefore, reducing waste in health facilities could generate substantial cost savings. The objective of this study is to show that Lean Six Sigma represents an appropriate methodology for the development of a clinical pathway which allows to improve quality and to reduce costs in prosthetic hip replacement surgery. The methodology used for the development of a new clinical pathway was Lean Six Sigma. Problem solving in Lean Six Sigma is the DMAIC (Define, Measure, Analyse, Improve, Control) roadmap, characterized by five operational phases which make possible to reach fixed goals through a rigorous process of defining, measuring, analysing, improving and controlling business problems. The following project indicated several variables influencing the inappropriate prolongation of the length of stay for inpatient treatment and corrective actions were performed to improve the effectiveness and efficiency of the process of care. The average length of stay was reduced from 18.9 to 10.6 days (-44%). This article shows there is no trade-off between quality and costs: Lean Six Sigma improves quality and, at the same time, reduces costs. © 2015 John Wiley & Sons, Ltd.

  4. Hereditary spherocytosis and elliptocytosis associated with prosthetic heart valve replacement: rheological study of erythrocyte modifications.

    Science.gov (United States)

    Caprari, Patrizia; Tarzia, Anna; Mojoli, Giorgio; Cianciulli, Paolo; Mannella, Emilio; Martorana, Maria Cristina

    2009-04-01

    The implantation of a prosthetic heart valve (HVP) in patients with hereditary spherocytosis (HS) and hereditary elliptocytosis (HE) is rare, and the changes in the structure and deformability of erythrocytes that follow implantation in these patients have been poorly described. In the present study, the erythrocytes in HS and HE patients with mechanical HVP were compared to the erythrocytes in patients with only congenital membrane defects, in terms of biochemical modifications and rheological behaviour. Integral and cytoskeletal erythrocyte membrane proteins were studied, and blood viscosity (shear rate/shear stress ratio), aggregation ratio [eta(1 s(-1))/eta(200 s(-1))], and red cell visco-elasticity were determined. Valve replacement with a mechanical prosthesis worsened anaemia and resulted in a change in haemolysis, from sub-clinical to evident. The rheological investigation of erythrocytes from HS patients confirmed the characteristic increased viscosity and aggregation ratio and the decreased deformability. The rheological behaviour of erythrocytes from patients with HVP showed a decrease in viscosity and an increase in elastic modulus. In these patients, the prosthesis seems to have induced traumatic damage to the erythrocyte membrane, leading to fragmentation and lysis, which in turn modified rheological parameters. The biochemical and rheological investigation allowed us to understand the clinical and haematological pictures of the patients and to describe the role played by different factors in haemolytic anaemia.

  5. A 6-DOF parallel bone-grinding robot for cervical disc replacement surgery.

    Science.gov (United States)

    Tian, Heqiang; Wang, Chenchen; Dang, Xiaoqing; Sun, Lining

    2017-12-01

    Artificial cervical disc replacement surgery has become an effective and main treatment method for cervical disease, which has become a more common and serious problem for people with sedentary work. To improve cervical disc replacement surgery significantly, a 6-DOF parallel bone-grinding robot is developed for cervical bone-grinding by image navigation and surgical plan. The bone-grinding robot including mechanical design and low level control is designed. The bone-grinding robot navigation is realized by optical positioning with spatial registration coordinate system defined. And a parametric robot bone-grinding plan and high level control have been developed for plane grinding for cervical top endplate and tail endplate grinding by a cylindrical grinding drill and spherical grinding for two articular surfaces of bones by a ball grinding drill. Finally, the surgical flow for a robot-assisted cervical disc replacement surgery procedure is present. The final experiments results verified the key technologies and performance of the robot-assisted surgery system concept excellently, which points out a promising clinical application with higher operability. Finally, study innovations, study limitations, and future works of this present study are discussed, and conclusions of this paper are also summarized further. This bone-grinding robot is still in the initial stage, and there are many problems to be solved from a clinical point of view. Moreover, the technique is promising and can give a good support for surgeons in future clinical work.

  6. Finite element study of a lumbar intervertebral disc nucleus replacement device

    Directory of Open Access Journals (Sweden)

    Jessica S Coogan

    2016-12-01

    Full Text Available Nucleus replacement technologies are a minimally invasive alternative to spinal fusion and total disc replacement that have the potential to reduce pain and restore motion for patients with degenerative disc disease. Finite element modeling can be used to determine the biomechanics associated with nucleus replacement technologies. The current study focuses on a new nucleus replacement device designed as a conforming silicone implant with an internal void. A validated finite element model of the human lumbar L3-L4 motion segment was developed and used to investigate the influence of the nucleus replacement device on spine biomechanics. In addition, the effect of device design changes on biomechanics was determined. A 3D, L3-L4 finite element model was constructed from medical imaging data. Models were created with the normal intact nucleus, the nucleus replacement device, and a solid silicone implant. Probabilistic analysis was performed on the normal model to provide quantitative validation metrics. Sensitivity analysis was performed on the silicone Shore A durometer of the device. Models were loaded under axial compression followed by flexion/extension, lateral bending, or axial rotation. Compressive displacement, endplate stresses, reaction moment, and annulus stresses were determined and compared between the different models. The novel nucleus replacement device resulted in similar compressive displacement, endplate stress, and annulus stress and slightly higher reaction moment compared with the normal nucleus. The solid implant resulted in decreased displacement, increased endplate stress, decreased annulus stress, and decreased reaction moment compared with the novel device. With increasing silicone durometer, compressive displacement decreased, endplate stress increased, reaction moment increased, and annulus stress decreased. Finite element analysis was used to show that the novel nucleus replacement device results in similar biomechanics

  7. A personalized 3D-printed prosthetic joint replacement for the human temporomandibular joint: From implant design to implantation.

    Science.gov (United States)

    Ackland, David C; Robinson, Dale; Redhead, Michael; Lee, Peter Vee Sin; Moskaljuk, Adrian; Dimitroulis, George

    2017-05-01

    Personalized prosthetic joint replacements have important applications in cases of complex bone and joint conditions where the shape and size of off-the-shelf components may not be adequate. The objective of this study was to design, test and fabricate a personalized 3D-printed prosthesis for a patient requiring total joint replacement surgery of the temporomandibular joint (TMJ). The new 'Melbourne' prosthetic TMJ design featured a condylar component sized specifically to the patient and fixation screw positions that avoid potential intra-operative damage to the mandibular nerve. The Melbourne prosthetic TMJ was developed for a 58-year-old female recipient with end-stage osteoarthritis of the TMJ. The load response of the prosthesis during chewing and a maximum-force bite was quantified using a personalized musculoskeletal model of the patient's masticatory system developed using medical images. The simulations were then repeated after implantation of the Biomet Microfixation prosthetic TMJ, an established stock device. The maximum condylar stresses, screw stress and mandibular stress at the screw-bone interface were lower in the Melbourne prosthetic TMJ (259.6MPa, 312.9MPa and 198.4MPa, respectively) than those in the Biomet Microfixation device (284.0MPa, 416.0MPa and 262.2MPa, respectively) during the maximum-force bite, with similar trends also observed during the chewing bite. After trialing surgical placement and evaluating prosthetic TMJ stability using cadaveric specimens, the prosthesis was fabricated using 3D printing, sterilized, and implanted into the female recipient. Six months post-operatively, the prosthesis recipient had a normal jaw opening distance (40.0 mm), with no complications identified. The new design features and immediate load response of the Melbourne prosthetic TMJ suggests that it may provide improved clinical and biomechanical joint function compared to a commonly used stock device, and reduce risk of intra-operative nerve damage

  8. Mixed reality simulation of rasping procedure in artificial cervical disc replacement (ACDR) surgery.

    Science.gov (United States)

    Halic, Tansel; Kockara, Sinan; Bayrak, Coskun; Rowe, Richard

    2010-10-07

    Until quite recently spinal disorder problems in the U.S. have been operated by fusing cervical vertebrae instead of replacement of the cervical disc with an artificial disc. Cervical disc replacement is a recently approved procedure in the U.S. It is one of the most challenging surgical procedures in the medical field due to the deficiencies in available diagnostic tools and insufficient number of surgical practices For physicians and surgical instrument developers, it is critical to understand how to successfully deploy the new artificial disc replacement systems. Without proper understanding and practice of the deployment procedure, it is possible to injure the vertebral body. Mixed reality (MR) and virtual reality (VR) surgical simulators are becoming an indispensable part of physicians' training, since they offer a risk free training environment. In this study, MR simulation framework and intricacies involved in the development of a MR simulator for the rasping procedure in artificial cervical disc replacement (ACDR) surgery are investigated. The major components that make up the MR surgical simulator with motion tracking system are addressed. A mixed reality surgical simulator that targets rasping procedure in the artificial cervical disc replacement surgery with a VICON motion tracking system was developed. There were several challenges in the development of MR surgical simulator. First, the assembly of different hardware components for surgical simulation development that involves knowledge and application of interdisciplinary fields such as signal processing, computer vision and graphics, along with the design and placements of sensors etc . Second challenge was the creation of a physically correct model of the rasping procedure in order to attain critical forces. This challenge was handled with finite element modeling. The third challenge was minimization of error in mapping movements of an actor in real model to a virtual model in a process called

  9. [Early effectiveness of discover cervical artificial disc replacement in treatment of cervical spondylosis].

    Science.gov (United States)

    Qian, Yufeng; Xue, Feng; Sheng, Xiaowen; Lu, Jianmin; Chen, Bingqian

    2012-03-01

    To investigate the early effectiveness of the Discover cervical artificial disc replacement in treating cervical spondylosis. Qualified for the selective standard, 24 patients with cervical spondylosis were treated between March 2010 and March 2011. Of 24 patients, 13 patients underwent anterior cervical decompression and fusion (ACDF) (ACDF group, between March 2010 and September 2010) and 11 patients underwent Discover cervical artificial disc replacement (CADR group, between September 2010 and March 2011). There was no significant difference in gender, age, disease duration, lesions typing, and affected segments between 2 groups (P > 0.05). The operative time, blood loss, and complications were recorded. Japanese Orthopaedic Association (JOA) scores, Neck Disability Index (NDI) scores, and Odom's scores were used to evaluate the postoperative effectiveness. In CADR group, the cervical range of motion (ROM) in all directions, and prosthesis eccentricity were measured before and after operation. Symptoms disappeared and no complication occurred after operation in the patients of 2 groups. The patients were followed up 12 to 18 months (mean, 15.3 months) in ACDF group and 6 to 12 months (mean, 9.6 months) in CADR group. The NDI scores in CADR group were significantly higher than those in ACDF group at 1, 3, and 6 months (P 0.05). According to Odom's score at last follow-up, the results were excellent in 6 cases, good in 4 cases, and fair in 3 cases with an excellent and good rate of 76.92% in ACDF group, and were excellent in 9 cases, good in 1 case, and poor in 1 case with an excellent and good rate of 90.91% in CADR group, showing no significant difference (chi2 = 3.000, P = 0.223). The patients in CADR group had significant limit of cervical joint ROM in flexion and extension and right bending at 1 month (P value (P < 0.05). Meanwhile, ROM in left bending were bigger than that in right bending in replaced segment and upper segment (P < 0.05), and the ROM

  10. The predisposing factors for the heterotopic ossification after cervical artificial disc replacement.

    Science.gov (United States)

    Yi, Seong; Shin, Dong Ah; Kim, Keung Nyun; Choi, Gwihyun; Shin, Hyun Chul; Kim, Keun Su; Yoon, Do Heum

    2013-09-01

    Heterotopic ossification (HO) is defined as a formation of bone outside the skeletal system. The reported HO occurrence rate in cervical artificial disc replacement (ADR) is unexpectedly high and is known to vary. However, the predisposing factors for HO in cervical ADR have not yet been elucidated. Investigation of the predisposing factors of HO in cervical arthroplasty and the relationship between degeneration of the cervical spine and HO occurrence. Retrospective study to discover predisposing factors of HO in cervical arthroplasty. A total of 170 patients who underwent cervical ADR were enrolled including full follow-up clinical and radiologic data. Radiologic outcomes were assessed by identification of HOs according to McAfee's classifications. This study enrolled a total of 170 patients who underwent cervical ADR. Pre-existing degenerative change included anterior or posterior osteophytes, ossification of the anterior longitudinal ligament, posterior longitudinal ligament, or ligamentum nuchae. The relationships between basic patient data, pre-existing degenerative change, and HO were investigated using linear logistic regression analysis. Among all 170 patients, HO was found in 69 patients (40.6%). Among the postulated predisposing factors, only male gender and artificial disc device type were shown to be statistically significant. Unexpectedly, preoperative degenerative changes in the cervical spine exerted no significant influence on the occurrence of HOs. The odds ratio of male gender compared with female gender was 2.117. With regard to device type, the odds ratios of Mobi-C (LDR medical, Troyes, France) and ProDisc-C (Synthes, Inc., West Chester, PA, USA) were 5.262 and 7.449, respectively, compared with the Bryan disc. Definite differences in occurrence rate according to the gender of patients and the prosthesis type were identified in this study. Moreover, factors indefinably expected to influence HO in the past were not shown to be risk factors

  11. A new three-dimensional, print-on-demand temporomandibular prosthetic total joint replacement system: Preliminary outcomes.

    Science.gov (United States)

    Dimitroulis, George; Austin, Stephen; Sin Lee, Peter Vee; Ackland, David

    2018-05-16

    The aim of this study is to present the preliminary clinical data on the OMX Temporomandibular Joint (TMJ) Prosthetic total joint replacement system. A prospective, cohort, clinical study was undertaken of consecutive adult patients with Category 5 end-stage joint disease who were implanted with the OMX TMJ prosthesis between May 2015 and April 2017. A total of 50 devices were implanted in 38 patients, with 12 patients receiving bilateral prosthetic joints. There were 31 females and 7 males in this cohort, who ranged in age from 20 to 66 years, with a mean of 43.8 years (±14.0 years). Ten of the 50 prosthetic joints (20%) were fully customized, while the remaining were patient matched using virtual planning software. Based on a mean follow-up period of 15.3 months (range 12-24 months) following the TMJ total joint replacement, preliminary results suggest the OMX TMJ prosthesis has made a positive impact on clinical outcomes, with a mean 74.4% reduction in joint pain levels and significant improvements (p < 0.05) in jaw function as measured by the visual analogue scales for mouth opening (30.8%), diet (77.1%), and function (59.2%). No device failures were reported during the study period. This study suggests that the print-on-demand OMX TMJ prosthesis, designed for rapid delivery of both patient-matched and fully customize devices, represents a safe, reliable and versatile implantable joint replacement system for the treatment of category 5 end-stage TMJ disease. Copyright © 2018 European Association for Cranio-Maxillo-Facial Surgery. Published by Elsevier Ltd. All rights reserved.

  12. Coil embolization of a false aneurysm with aorto-cutaneous fistula after prosthetic graft replacement of the ascending aorta

    International Nuclear Information System (INIS)

    Miguel, Bruno; Camilleri, Lionel; Gabrillargues, Jean; Macheda, Bruno; Kubota, Hiroshi; Ravel, Anne; Riberolles, Charles de; Boyer, Louis

    2000-01-01

    Aim: To report palliative embolization of a false aneurysm over the distal suture line of an ascending aorta graft replacement. Material and Method: A 78-year-old male patient was admitted for increasing bleeding of a chronic Manubrium ulceration, 20 months after coronary artery bypass complicated by perioperative ascending aorta dissection requiring prosthetic graft replacement. One month later, he underwent epiploplasty for a mediastinitis followed by long-term antibiotic therapy. Five months later, he presented with a Manubrium ulceration of the sternotomy. Spiral computerized tomography (CT) and aortography revealed a 20 mm anterior peri-prosthetic false aneurysm with a wide neck. Advanced age, active mediastinitis and patient's objection led us to perform percutaneous occlusion according to the Moret remodeling technique while protecting the coils release with balloon catheter inflation. Results: No post-operative complication was observed and at 1-year follow-up the patient was doing well with no recurrent bleeding. Magnetic resonance imaging (MRI) and spiral CT controls confirmed coils stability without any internal flow. Conclusion: Percutaneous coils embolization of a large false aneurysm in the ascending aorta can be a palliative treatment in a surgically unsuited patient

  13. Measurement of installation deformation of the acetabulum during prosthetic replacement of a hip joint using digital image correlation

    Science.gov (United States)

    Lei, Dong; Bai, Pengxiang; Zhu, Feipeng

    2018-01-01

    Nowadays, acetabulum prosthesis replacement is widely used in clinical medicine. However, there is no efficient way to evaluate the implantation effect of the prosthesis. Based on a modern photomechanics technique called digital image correlation (DIC), the evaluation method of the installation effect of the acetabulum was established during a prosthetic replacement of a hip joint. The DIC method determines strain field by comparing the speckle images between the undeformed sample and the deformed counterpart. Three groups of experiments were carried out to verify the feasibility of the DIC method on the acetabulum installation deformation test. Experimental results indicate that the installation deformation of acetabulum generally includes elastic deformation (corresponding to the principal strain of about 1.2%) and plastic deformation. When the installation angle is ideal, the plastic deformation can be effectively reduced, which could prolong the service life of acetabulum prostheses.

  14. Cost-effectiveness of cervical total disc replacement vs fusion for the treatment of 2-level symptomatic degenerative disc disease.

    Science.gov (United States)

    Ament, Jared D; Yang, Zhuo; Nunley, Pierce; Stone, Marcus B; Kim, Kee D

    2014-12-01

    Cervical total disc replacement (CTDR) was developed to treat cervical spondylosis, while preserving motion. While anterior cervical discectomy and fusion (ACDF) has been the standard of care for 2-level disease, a randomized clinical trial (RCT) suggested similar outcomes. Cost-effectiveness of this intervention has never been elucidated. To determine the cost-effectiveness of CTDR compared with ACDF. Data were derived from an RCT that followed up 330 patients over 24 months. The original RCT consisted of multi-institutional data including private and academic institutions. Using linear regression for the current study, health states were constructed based on the stratification of the Neck Disability Index and a visual analog scale. Data from the 12-item Short-Form Health Survey questionnaires were transformed into utilities values using the SF-6D mapping algorithm. Costs were calculated by extracting Diagnosis-Related Group codes from institutional billing data and then applying 2012 Medicare reimbursement rates. The costs of complications and return-to-work data were also calculated. A Markov model was built to evaluate quality-adjusted life-years (QALYs) for both treatment groups. The model adopted a third-party payer perspective and applied a 3% annual discount rate. Patients included in the original RCT had to be diagnosed as having radiculopathy or myeloradiculopathy at 2 contiguous levels from C3-C7 that was unresponsive to conservative treatment for at least 6 weeks or demonstrated progressive symptoms. Incremental cost-effectiveness ratio of CTDR compared with ACDF. A strong correlation (R2 = 0.6864; P sensitivity analysis, the incremental cost-effectiveness ratio value stays below the threshold of $50,000 per QALY in most scenarios (range, -$58,194 to $147,862 per QALY). The incremental cost-effectiveness ratio of CTDR compared with traditional ACDF is lower than the commonly accepted threshold of $50,000 per QALY. This remains true with varying input

  15. Fracture and embolization of a Björk-Shiley disc. Fatal failure of a prosthetic mitral valve.

    Science.gov (United States)

    Norenberg, D D; Evans, R W; Gundersen, A E; Abellera, R M

    1977-12-01

    A case of fracture of the disc occluder of a Bjork-Shiley mitral prosthesis with embolization of the disc fragments to distal aorta is presented. The possibility of valve dysfunction and the diagnostic value of echocardiography should be considered whenever acute heart failure occurs in a patient with an artificial valve.

  16. Metal-containing lymph nodes following prosthetic replacement of osseous malignancy: potential role of MR imaging in characterisation

    Energy Technology Data Exchange (ETDEWEB)

    Davies, A.M.; Cooper, S.A. [Dept. of Radiology, Royal Orthopaedic Hospital, Birmingham (United Kingdom); Mangham, D.C. [Dept. of Pathology, Royal Orthopaedic Hospital, Birmingham (United Kingdom); Grimer, R.J. [Dept. of Orthopaedic Oncology, Royal Orthopaedic Hospital, Birmingham (United Kingdom)

    2001-05-01

    The identification of regional lympadenopathy in patients with bone malignancy treated by excision and insertion of a prosthesis usually indicates metastatic disease. We present two cases in which the lymphadenopathy was due to an uncommon but well-recognized foreign body reaction. This is secondary to the lymphatic uptake of metal debris shed by the prosthesis. In one case the metal within the excised lymph node could be demonstrated on in vitro MR imaging and in retrospect on the original in vivo scans. This condition should be considered when undertaking an MR examination in patients with bone malignancy treated by prosthetic replacement in whom there is a clinical suspicion of metastatic spread to the regional lymph nodes. (orig.)

  17. Posterior Transpedicular Dynamic Stabilization versus Total Disc Replacement in the Treatment of Lumbar Painful Degenerative Disc Disease: A Comparison of Clinical Results

    Directory of Open Access Journals (Sweden)

    Tunc Oktenoglu

    2013-01-01

    Full Text Available Study Design. Prospective clinical study. Objective. This study compares the clinical results of anterior lumbar total disc replacement and posterior transpedicular dynamic stabilization in the treatment of degenerative disc disease. Summary and Background Data. Over the last two decades, both techniques have emerged as alternative treatment options to fusion surgery. Methods. This study was conducted between 2004 and 2010 with a total of 50 patients (25 in each group. The mean age of the patients in total disc prosthesis group was 37,32 years. The mean age of the patients in posterior dynamic transpedicular stabilization was 43,08. Clinical (VAS and Oswestry and radiological evaluations (lumbar lordosis and segmental lordosis angles of the patients were carried out prior to the operation and 3, 12, and 24 months after the operation. We compared the average duration of surgery, blood loss during the surgery and the length of hospital stay of both groups. Results. Both techniques offered significant improvements in clinical parameters. There was no significant change in radiologic evaluations after the surgery for both techniques. Conclusion. Both dynamic systems provided spine stability. However, the posterior dynamic system had a slight advantage over anterior disc prosthesis because of its convenient application and fewer possible complications.

  18. Development of a clinically relevant impingement test method for a mobile bearing lumbar total disc replacement.

    Science.gov (United States)

    Siskey, Ryan; Peck, Jonathan; Mehta, Hitesh; Kosydar, Allison; Kurtz, Steven; Hill, Genevieve

    2016-09-01

    Total disc arthroplasty is an alternative therapy to spinal fusion for the treatment of neck or low back pain and is hypothesized to reduce the risk of disease progression to the adjacent spinal levels. Radiographic and retrieval analyses of various total disc replacements (TDRs) have shown evidence of impingement damage. Impingement of TDRs can occur when the device reaches the limits of its functional range of motion, causing contact between peripheral regions of the device. Impingement can be associated with increased wear and mechanical damage; however, impingement conditions are not simulated in current standardized mechanical bench test methods. This study explored the test conditions necessary to apply clinically relevant impingement loading to a lumbar TDR in vitro. An experimental protocol was developed and evaluated using in vivo retrievals for qualitative and quantitative validation. Retrieval analysis was conducted on a set of 11 size 3 retrieved Charité devices using American Society for Testing and Materials F561 as a guide. The impingement range of motion was determined using a combination of modeling and experiments, and was used as an input in vitro testing. A 1-million cycle in vitro test was then conducted, and the in vitro samples were characterized using methods similar to the retreived devices. All in vitro tested samples exhibited impingement regions and damage patterns consistent with retrieved devices. Consistent with the retrievals, the impingement damage on the rim was a combination of abrasive wear and plastic deformation. Micro computed tomography (microCT) was used to quantitatively assess rim damage due to impingement. Rim penetration was statistically lower in the retrievals when compared with both in vitro groups. Rim elongation was comparable among all groups. The simulated-facet group had statistically greater angular rim deformations than the retrieval group and the no-facet group. Results demonstrate that clinically relevant

  19. [Social and professional effects of hip prosthetic replacment on people under 50 years of age].

    Science.gov (United States)

    Xenard, J

    1996-12-01

    Although total hip prosthetic replacement is a common surgical procedure, it is not without social and professional consequences. In a certain number of cases, return to occupational activities is not possible. In others, it is difficult. Long-term work break repercussions can be major as they often go together with financial difficulties. The medical counsultant and the occupational doctor will have an important role to play at the time of the return to occupational activities or to determine the conditions of workplace adaptation or a vocational training program.Functional recovery after insertion of total hip prosthesis observes precise rules of articular mobilization, weight bearing and muscular strengthening.In the young patient, before 50 years old, objectives will be more accurate and progress not only will concern recovery of daily living, walking and do-it-yourself activities but also return to sports, play and occupational activities. Not only will reactivation be physical, muscular and articular but also behavioral and psychological.Disease and its consequences, surgery in particular, cause a psychological and a physical aggression which modifies the patient's self-concept. • Vulnerability and plastic wrong (limping, modifications of gesture and sports performanee as well as modifications of the living conditions). The patient unconsciously translates this physical affection into: * loneliness (taking away or exclusion from the usual surroundings of those who are in good health) * "blues" * lack of dynamism * uselessness, feeling of being incompetent "in those conditions, what's the use of fighting?" ٜ At the same time - loss of social status: "Colleagues get up to go to work, children go to school, all the others are productive, I'm good at nothing." - impression of uselessness, dependence; reinforcement of turning in on the self. •The undertaking by a surgeon and his team (anaesthetist, nurse, physiotherapist) which implies constraints, orders

  20. Laxity of the elbow after experimental excision of the radial head and division of the medial collateral ligament. Efficacy of ligament repair and radial head prosthetic replacement

    DEFF Research Database (Denmark)

    Jensen, S.L.; Deutch, S.R.; Olsen, B.S.

    2003-01-01

    We studied the stabilising effect of prosthetic replacement of the radial head and repair of the medial collateral ligament (MCL) after excision of the radial head and section of the MCL in five cadaver elbows. Division of the MCL increased valgus angulation (mean 3.9 +/- 1.5 degrees) and internal...

  1. The Mobi-C cervical disc for one-level and two-level cervical disc replacement: a review of the literature

    Directory of Open Access Journals (Sweden)

    Alvin MD

    2014-11-01

    with cervical degenerative disc disease. The Mobi-C CDA procedure is associated with high rates of HO. Two-level Mobi-C CDA may be superior to two-level ACDF. However, insufficient evidence exists, thereby mandating a need for unbiased, well-designed prospective studies with well-defined outcomes in the future.Keywords: Mobi-C, cervical disc arthroplasty, total disc replacement, ACDF, quality of life, outcomes, effectiveness, cervical spine

  2. Preferential superior surface motion in wear simulations of the Charité total disc replacement.

    Science.gov (United States)

    Goreham-Voss, Curtis M; Vicars, Rachel; Hall, Richard M; Brown, Thomas D

    2012-06-01

    Laboratory wear simulations of the dual-bearing surface Charité total disc replacement (TDR) are complicated by the non-specificity of the device's center of rotation (CoR). Previous studies have suggested that articulation of the Charité preferentially occurs at the superior-bearing surface, although it is not clear how sensitive this phenomenon is to lubrication conditions or CoR location. In this study, a computational wear model is used to study the articulation kinematics and wear of the Charité TDR. Implant wear was found to be insensitive to the CoR location, although seemingly non-physiologic endplate motion can result. Articulation and wear were biased significantly to the superior-bearing surface, even in the presence of significant perturbations of loading and friction. The computational wear model provides novel insight into the mechanics and wear of the Charité TDR, allowing for better interpretation of in vivo results, and giving useful insight for designing future laboratory physical tests.

  3. Efficacy of a novel strategy for poststernotomy deep sternal infection after thoracic aorta replacement using a prosthetic graft.

    Science.gov (United States)

    Kuriyama, Motone; Yoshida, Yukitaka; Ninomiya, Hitoshi; Yamamoto, Shin; Sasaguri, Shiro; Akita, Shinsuke; Mitsukawa, Nobuyuki

    2018-05-01

    Poststernotomy deep sternal wound infections are persistent and occasionally fatal, especially in cases involving prosthetic grafts, because of their complicated structure and virtual impossibility of removal. We aimed to verify the influence of cooperation with plastic surgeons and our novel strategy for treating deep sternal wound infection after aortic replacement on cardiovascular surgery outcomes. Nine hundred eighty-three consecutive patients were divided into two groups: an early group (2012-2013) and a late group (2014-2015). The late group had received cooperatively improved perioperative wound management: our novel strategy of deep sternal infection based on radical debridement and immediate reconstruction decided by reference to severities of the patient's general condition and widespread infection by early intervention of plastic surgeons. The groups were analysed retrospectively. Binary variables were analysed statistically with the Fisher exact test and continuous variables with the Mann-Whitney U test. Inter-group differences were assessed with the chi-square test. Twenty of 390 cases in the early group and 13 of 593 cases in the late group were associated with deep sternal infection. Morbidity rates of deep sternal wound infection and associated mortality rates 1 year after reconstruction surgery were significantly less (p infection also reduced associated mortality rates. Facilities should consider the early inclusion of plastic surgeons in the treatment of patients undergoing aortic replacement to facilitate better outcomes. Copyright © 2018 British Association of Plastic, Reconstructive and Aesthetic Surgeons. Published by Elsevier Ltd. All rights reserved.

  4. Improvement of chronic corneal opacity in ocular surface disease with prosthetic replacement of the ocular surface ecosystem (PROSE) treatment.

    Science.gov (United States)

    Cressey, Anna; Jacobs, Deborah S; Remington, Crystal; Carrasquillo, Karen G

    2018-06-01

    To demonstrate clearing of chronic corneal opacities and improvement of visual acuity with the use of BostonSight prosthetic replacement of the ocular surface ecosystem (PROSE) treatment in ocular surface disease. We undertook retrospective analysis of the medical records of a series of patients who underwent PROSE treatment from August 2006 to December 2014. Patients were referred for ocular surface disease of various etiologies. Primary inclusion criterion was corneal opacity that improved with PROSE treatment. Patients were excluded if topical steroids or adjuvant therapy used once PROSE treatment was initiated. Underlying disease, prior treatment, clinical presentation, and clinical course were extracted from the medical record. Four patients are included in this series. There were three females and one male; median age at time of treatment initiation was 30 years (range = 0.5-58 years). Median duration of PROSE treatment at time of retrospective analysis was 3.5 years (range = 1-8 years). Two cases had corneal opacification in the context of neurotrophic keratopathy: a unilateral case due to presumed herpes simplex keratitis and a bilateral case due to congenital corneal anesthesia associated with familial dysautonomia. One case had corneal opacity from exposure related to seventh nerve palsy, and one had corneal opacification associated with recurrent surface breakdown, neurotrophic keratopathy, and limbal stem deficiency of uncertain etiology. After consistent wear of prosthetic devices used in PROSE treatment for support of the ocular surface, visual acuity improved and clearing of the opacities was observed, without use of topical steroids or adjuvant therapy. These cases demonstrate clearing of chronic corneal opacity with PROSE treatment for ocular surface disease. This clearing can occur with no adjuvant therapy, suggesting that restoration of ocular surface function and integrity allows for corneal remodeling.

  5. Custom-tailored tissue engineered polycaprolactone scaffolds for total disc replacement

    International Nuclear Information System (INIS)

    Van Uden, S; Silva-Correia, J; Correlo, V M; Oliveira, J M; Reis, R L

    2015-01-01

    fibroblast’s cell line. This study proposed a simple, rapid, and low-cost strategy to fabricate custom-tailored annulus fibrosus scaffolds. In the future, this strategy might be used in association with nucleus pulposus regeneration strategies to facilitate the development of tissue-engineered total disc replacement implants specific to each patient, with a goal of full IVD regeneration. (paper)

  6. Comparison of total disc replacement with lumbar fusion: a meta-analysis of randomized controlled trials

    International Nuclear Information System (INIS)

    Nie, H.

    2015-01-01

    A meta-analysis was performed to evaluate whether a beneficial clinical effect of the Total Disc Replacement (TDR) over lumbar fusion for the treatment of patients with Degenerative Disc Disease (DDD). An electronic search of PubMed, Cochrane Central Register of Controlled Trials, and EMBASE from their inception to 2012 was completed, and we assessed risk bias and retrieved relevant data, and meta-analysis was performed, if appropriate. Oswestry Disability Index (ODI), Visual Analog Score (VAS), patient satisfaction or VAS patient satisfaction, narcotic use, overall success rate, reoperation rate, work status, surgery again, complications and radiographic outcomes were evaluated. Six RCTs were included in this meta-analysis. At 2 years, TDR was demonstrated to be more beneficial for patients compared to lumbar fusion in the following outcomes, including ODI scores (MD: -4.87, 95% CI: -7.77 to -1.97, p=0.001), patient satisfaction (OR:1.91, 95% CI: 1.27 to 2.86, p=0.002) and VAS patient satisfaction (MD:9.10, 95% CI: 3.20 to 14.99, p=0.002), the percentage of using narcotics (OR=0.54, 95%CI: 0.31 to 0.96, p=0.03), overall success rate (OR:1.68, 95% CI: 1.26 to 2.25, p=0.005), the rate of patients to chose the same surgical treatment again (OR:2.38, 95% CI: 1.72 to 3.28, p < 0.001), and complications (OR=0.50, 95% CI: 0.29 to 0.84, p=0.008). Other outcomes, including re-operation rate (OR:0.62, 95% CI: 0.36 to 1.06, p=0.08) and work status (OR=1.05, 95% CI: 0.75 to 1.47, p=0.80), were demonstrated to be no differences between the two groups. In a long-term of follow-up (2 years), TDR shows a significant superiority for the treatment of lumbar DDD compared with fusion. (author)

  7. Seven-year cost-effectiveness of ProDisc-C total disc replacement: results from investigational device exemption and post-approval studies.

    Science.gov (United States)

    Radcliff, Kris; Lerner, Jason; Yang, Chao; Bernard, Thierry; Zigler, Jack E

    2016-05-01

    OBJECTIVE The purpose of this study was to evaluate the 7-year cost-effectiveness of cervical total disc replacement (CTDR) versus anterior cervical discectomy and fusion (ACDF) for the treatment of patients with single-level symptomatic degenerative disc disease. A change in the spending trajectory for spine care is to be achieved, in part, through the selection of interventions that have been proven effective yet cost less than other options. This analysis complements and builds upon findings from other cost-effectiveness evaluations of CTDR through the use of long-term, patient-level data from a randomized study. METHODS This was a 7-year health economic evaluation comparing CTDR versus ACDF from the US commercial payer perspective. Prospectively collected health care resource utilization and treatment effects (quality-adjusted life years [QALYs]) were obtained from individual patient-level adverse event reports and SF-36 data, respectively, from the randomized, multicenter ProDisc-C total disc replacement investigational device exemption (IDE) study and post-approval study. Statistical distributions for unit costs were derived from a commercial claims database and applied using Monte Carlo simulation. Patient-level costs and effects were modeled via multivariate probabilistic analysis. Confidence intervals for 7-year costs, effects, and net monetary benefit (NMB) were obtained using the nonparametric percentile method from results of 10,000 bootstrap simulations. The robustness of results was assessed through scenario analysis and within a parametric regression model controlling for baseline variables. RESULTS Seven-year follow-up data were available for more than 70% of the 209 randomized patients. In the base-case analysis, CTDR resulted in mean per-patient cost savings of $12,789 (95% CI $5362-$20,856) and per-patient QALY gains of 0.16 (95% CI -0.073 to 0.39) compared with ACDF over 7 years. CTDR was more effective and less costly in 90.8% of probabilistic

  8. Internal Prosthetic Replacement of Skeletal Segments Lost in Combat Related Injuries.

    Science.gov (United States)

    1981-08-01

    general anesthesia using sterile techniques. Both legs were operated in one session. Antibiotic prophylaxis with clindamycin was given routinely. The...elevate the pelvis. General inhalation anesthesia is used and intravenous fluid replacement is available to correct fluid loss. The left lower limb is...after evacuation to a primary care facility. Operation #1. General endotracheal anesthesia was administered. The leg was shaved but not prepped, and was

  9. Prosthetic liner wear in total hip replacement: a longitudinal 13-year study with computed tomography.

    Science.gov (United States)

    Weidenhielm, Lars; Olivecrona, Henrik; Maguire, Gerald Q; Noz, Marilyn E

    2018-06-01

    This case report follows a woman who had a total hip replacement in 1992 when she was 45 years old. Six serial computed tomography (CT) examinations over a period of 13 years provided information that allowed her revision surgery to be limited to liner replacement as opposed to replacement of the entire prosthesis. Additionally, they provided data that ruled out the presence of osteolysis and indeed none was found at surgery. In 2004, when the first CT was performed, the 3D distance the femoral head had penetrated into the cup was determined to be 2.6 mm. By 2017, femoral head penetration had progressed to 5.0 mm. The extracted liner showed wear at the thinnest part to be 5.5 mm, as measured with a micrometer. The use of modern CT techniques can identify problems, while still correctable without major surgery. Furthermore, the ability of CT to assess the direction of wear revealed that the liner wear changed from the cranial to dorsal direction.

  10. Regression in left ventricular mass after aortic valve replacement for chronic aortic regurgitation is unrelated to prosthetic valve size.

    Science.gov (United States)

    Brown, Morgan L; Schaff, Hartzell V; Suri, Rakesh M; Li, Zhuo; Sundt, Thoralf M; Dearani, Joseph A; Enriquez-Sarano, Maurice

    2011-08-01

    We examined the role of prosthesis-patient mismatch on left ventricular mass regression after aortic valve replacement for chronic aortic valve regurgitation. We selected patients who had complete preoperative and follow-up echocardiograms with measurement of left ventricular mass. Patients were excluded who had moderate or greater aortic valve stenosis, concomitant coronary artery bypass grafting, or mitral valve procedures. Patients' mean age was 55 ± 17 years; 21% were female. The mean preoperative indexed left ventricular mass was 150 ± 45 g/m(2). Patients with mildly (n = 44; mean indexed mass, 126 ± 15 g/m(2)), moderately (n = 31; mean indexed mass, 168 ± 11 g/m(2)), or severely (n = 15; mean indexed mass, 241 ± 34 g/m(2)) increased preoperative indexed left ventricular mass, were similar, except for lower ejection fractions, larger end-diastolic dimensions, and larger ventricular wall thicknesses in the severely enlarged group (P regression was unrelated to labeled valve size, prosthesis-patient mismatch, or measured indexed effective aortic valve area. A greater preoperative indexed left ventricular mass (P regression. Despite having greater left ventricular mass regression, patients with severe preoperative indexed left ventricular mass did not return to normal values (mean, 142 ± 25 g/m(2)). Left ventricular mass regression after aortic valve replacement for chronic aortic regurgitation is unrelated to indexed prosthetic valve area. Although incomplete, regression is greatest in patients with the largest preoperative indexed left ventricular mass. Copyright © 2011 The American Association for Thoracic Surgery. Published by Mosby, Inc. All rights reserved.

  11. Pannus-related prosthetic valve dysfunction. Case report.

    Science.gov (United States)

    Moldovan, Maria-Sînziana; Bedeleanu, Daniela; Kovacs, Emese; Ciumărnean, Lorena; Molnar, Adrian

    2016-01-01

    Pannus-related prosthetic valve dysfunction, a complication of mechanical prosthetic valve replacement, is rare, with a slowly progressive evolution, but it can be acute, severe, requiring surgical reintervention. We present the case of a patient with a mechanical single disc aortic prosthesis, with moderate prosthesis-patient mismatch, minor pannus found on previous ultrasound examinations, who presented to our service with angina pain with a duration of 1 hour, subsequently interpreted as non-ST segment elevation myocardial infarction (NSTEMI) syndrome. Coronarography showed normal epicardial coronary arteries, an ample movement of the prosthetic disc, without evidence of coronary thromboembolism, and Gated Single-Photon Emission Computerized Tomography (SPECT) with Technetium (Tc)-99m detected no perfusion defects. Transthoracic echocardiography (TTE) evidenced a dysfunctional prosthesis due to a subvalvular mass; transesophageal echocardiography (TOE) showed the interference of this mass, with a pannus appearance, with the closure of the prosthetic disc. Under conditions of repeated angina episodes, under anticoagulant treatment, surgery was performed, with the intraoperative confirmation of pannus and its removal. Postoperative evolution was favorable. This case reflects the diagnostic and therapeutic management problems of pannus-related prosthetic valve dysfunction.

  12. Transcatheter pulmonary valve replacement by hybrid approach using a novel polymeric prosthetic heart valve: proof of concept in sheep.

    Directory of Open Access Journals (Sweden)

    Ben Zhang

    Full Text Available Since 2000, transcatheter pulmonary valve replacement has steadily advanced. However, the available prosthetic valves are restricted to bioprosthesis which have defects like poor durability. Polymeric heart valve is thought as a promising alternative to bioprosthesis. In this study, we introduced a novel polymeric transcatheter pulmonary valve and evaluated its feasibility and safety in sheep by a hybrid approach.We designed a novel polymeric trileaflet transcatheter pulmonary valve with a balloon-expandable stent, and the valve leaflets were made of 0.1-mm expanded polytetrafluoroethylene (ePTFE coated with phosphorylcholine. We chose glutaraldehyde-treated bovine pericardium valves as control. Pulmonary valve stents were implanted in situ by a hybrid transapical approach in 10 healthy sheep (8 for polymeric valve and 2 for bovine pericardium valve, weighing an average of 22.5±2.0 kg. Angiography and cardiac catheter examination were performed after implantation to assess immediate valvular functionality. After 4-week follow-up, angiography, echocardiography, computed tomography, and cardiac catheter examination were used to assess early valvular function. One randomly selected sheep with polymeric valve was euthanized and the explanted valved stent was analyzed macroscopically and microscopically.Implantation was successful in 9 sheep. Angiography at implantation showed all 9 prosthetic valves demonstrated orthotopic position and normal functionality. All 9 sheep survived at 4-week follow-up. Four-week follow-up revealed no evidence of valve stent dislocation or deformation and normal valvular and cardiac functionality. The cardiac catheter examination showed the peak-peak transvalvular pressure gradient of the polymeric valves was 11.9±5.0 mmHg, while that of two bovine pericardium valves were 11 and 17 mmHg. Gross morphology demonstrated good opening and closure characteristics. No thrombus or calcification was seen macroscopically

  13. Measurements of three-dimensional glenoid erosion when planning the prosthetic replacement of osteoarthritic shoulders.

    Science.gov (United States)

    Terrier, A; Ston, J; Larrea, X; Farron, A

    2014-04-01

    The three-dimensional (3D) correction of glenoid erosion is critical to the long-term success of total shoulder replacement (TSR). In order to characterise the 3D morphology of eroded glenoid surfaces, we looked for a set of morphological parameters useful for TSR planning. We defined a scapular coordinates system based on non-eroded bony landmarks. The maximum glenoid version was measured and specified in 3D by its orientation angle. Medialisation was considered relative to the spino-glenoid notch. We analysed regular CT scans of 19 normal (N) and 86 osteoarthritic (OA) scapulae. When the maximum version of OA shoulders was higher than 10°, the orientation was not only posterior, but extended in postero-superior (35%), postero-inferior (6%) and anterior sectors (4%). The medialisation of the glenoid was higher in OA than normal shoulders. The orientation angle of maximum version appeared as a critical parameter to specify the glenoid shape in 3D. It will be very useful in planning the best position for the glenoid in TSR.

  14. Segmental translation after lumbar total disc replacement using Prodisc-L®: associated factors and relation to facet arthrosis.

    Science.gov (United States)

    Shin, Myung H; Ryu, Kyeong S; Rathi, Nitesh K; Park, Chun K

    2017-02-01

    Segmental translation after lumbar total disc replacement (TDR) with ProDisc-L® prosthesis frequently observed radiographic findings during follow-up period. However its precise pathomechanism and relation with facet arthrosis have not been investigated yet. This study was performed to evaluate possible factors that affect postoperative segmental translation and to identify its relation with facet joint degeneration after lumbar TDR using ProDisc-L® prosthesis. Thirty-five consecutive patients, who underwent lumbar TDR using ProDisc-L®, completed minimum 24 months follow-up. Segmental translation was assessed postoperatively at 1 month and at least at 24 months by using dynamic plain radiograph. Segmental translation was assessed in relation to patient age, sex, change of functional spinal unit (FSU) height, segmental range of motion (ROM), global lumbar ROM, implanted level, relative prosthesis size and prosthesis position. The comparison of segmental translation between progressive facet arthrosis (PFA) group and non-PFA group was also made. The mean segmental translation was 0.49±0.49 mm at 1 month after surgery and showed significant increase to 0.83±0.78 mm at last follow-up (P=0.014). Change of FSU height, segmental ROM, global lumbar ROM, implanted level and relative size of prosthesis were the significant factors among the variables related to segmental translation that authors assessed (P=0.032, P=0.000, P=0.001, P=0.046 and P=0.042, respectively). There was no significant intergroup difference of mean segmental translation between PFA group and non-PFA group (P=0.586). This study demonstrates that segmental translation after TDR using ProDisc-L® has significant relations with change of FSU height, segmental ROM, global lumbar ROM, implanted level and relative size of prosthesis. With the intergroup comparison, PFA group did not show significant higher segmental translation than non-PFA group.

  15. Socioeconomic indicators and prosthetic replacement of missing teeth in a working-age population--results of the Study of Health in Pomerania (SHIP).

    Science.gov (United States)

    Mundt, Torsten; Polzer, Ines; Samietz, Stefanie; Grabe, Hans Jörgen; Messerschmidt, Heidrun; Dören, Martina; Schwarz, Sabine; Kocher, Thomas; Biffar, Reiner; Schwahn, Christian

    2009-04-01

    To analyse the possible effects of the socioeconomic status (SES) on the prosthetic replacement of missing teeth in working-age people and to explore the role of potential confounders. Cross-sectional data were collected from 2310 German adults aged 30-59 years. The relationship between each of the three SES indicators (education, income, and occupational status) and dental prostheses were examined by multinomial logistic regression analyses. For that, partially dentate participants with suboptimal and no replacement of missing teeth were compared with partially dentate participants having optimal replacement. Potential confounders (age, sex, dental status, social network and social support) were entered if their inclusion in the model led to >or= 10% change in the coefficient of interest. Social network and social support did not meet the criterion for confounding. In the maxilla, having no replacement was positively associated with lower categories for each of the three SES indicators [Odds ratios (OR) between 1.6 and 2.1; 95% confidence intervals (CI) between 1.1 and 3.4]. Low occupational status was the single predictor for suboptimal dental prostheses (OR=3.2; 95% CI: 1.6-6.2). In the mandible, occupational status showed no association with the prosthetic status, whereas low educational level and low household income were determinants for having no replacement (OR=1.9 and 1.9, 95% CI: 1.0-3.5 and 1.1-3.0, respectively). Low household income was the single determinant for suboptimal replacement of missing teeth (OR=2.4, 95% CI=1.1-5.2). The findings may indicate the relevance of the financing of prosthodontic treatment. The strong association between various forms of upper dentures and occupational prestige can be seen as key contributing concept to how individuals' characteristics affect the outcome in prosthodontic care.

  16. The efficacy of {sup 99m}Tc-ciprofloxacin (infecton) imaging in suspected prosthetic infection following total knee replacement arthroplasty (pilot study)

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Jong Ho; Choi, Tae Hyun; Kim, Nam Bum [Gachon Medical School, Incheon (Korea, Republic of)

    2002-07-01

    The aims of this study were 1) to increase the labelling efficiency of {sup 99m}Tc-ciprofloxacin (infecton) and 2) to determine the value of infecton imaging in demonstrating infection following total knee replacement arthroplasty (TKRA). Five patients (4 female, 1 male: mean age 52.8{+-}13.5 years, both TKRA in 3 pt) with suspected prosthetic infective conditions were included. In order to increase labelling efficiency, infection was labelled with stannous tartrate instead of previousely used formamidine sulfinic acid (FSA). Immediate perfusion, 5min blood pool, 1hr, 4hr and 24hr delayed images were perfomed. All images were blindly interpreted by two independent observers with visual findings being classified according to a four-grade scale(0.1.2.3). Images graded 0 and 1, and also those regions which showed faintly increase or unchanged uptake grade on late images as compared with early images, were classified as negative; grades 2 and 3 were classified as positive. The diagnosis was confirmed by intraoperative microbiological / histological findings or by the presence of gross purulence. Labelling efficiency increased up to over 98% with formation of radiocolloid less than 1%. All of four pt with prosthetic infection showed positive infecton images but one pt with sterile loosening of prosthesis showed negative infection images. The easy availability as well as new labelling technique make infecton imaging the better option for the detection of prosthetic orthopedic infection.

  17. The efficacy of 99mTc-ciprofloxacin (infecton) imaging in suspected prosthetic infection following total knee replacement arthroplasty (pilot study)

    International Nuclear Information System (INIS)

    Kim, Jong Ho; Choi, Tae Hyun; Kim, Nam Bum

    2002-01-01

    The aims of this study were 1) to increase the labelling efficiency of 99m Tc-ciprofloxacin (infecton) and 2) to determine the value of infecton imaging in demonstrating infection following total knee replacement arthroplasty (TKRA). Five patients (4 female, 1 male: mean age 52.8±13.5 years, both TKRA in 3 pt) with suspected prosthetic infective conditions were included. In order to increase labelling efficiency, infection was labelled with stannous tartrate instead of previousely used formamidine sulfinic acid (FSA). Immediate perfusion, 5min blood pool, 1hr, 4hr and 24hr delayed images were perfomed. All images were blindly interpreted by two independent observers with visual findings being classified according to a four-grade scale(0.1.2.3). Images graded 0 and 1, and also those regions which showed faintly increase or unchanged uptake grade on late images as compared with early images, were classified as negative; grades 2 and 3 were classified as positive. The diagnosis was confirmed by intraoperative microbiological / histological findings or by the presence of gross purulence. Labelling efficiency increased up to over 98% with formation of radiocolloid less than 1%. All of four pt with prosthetic infection showed positive infecton images but one pt with sterile loosening of prosthesis showed negative infection images. The easy availability as well as new labelling technique make infecton imaging the better option for the detection of prosthetic orthopedic infection

  18. Retrieval of a leaflet escaped in a Tri-technologies bileaflet mechanical prosthetic valve.

    Science.gov (United States)

    Cianciulli, Tomás F; Lax, Jorge A; Saccheri, María C; Guidoin, Robert; Salvado, César M; Fernández, Adrián J; Prezioso, Horacio A

    2008-01-01

    The escape of the prosthetic heart valve disc is one of the causes of prosthetic dysfunction that requires emergency surgery. The removal of the embolized disc should be carried out because of the risk of a progressive extrusion on the aortic wall. Several imaging techniques can be used for the detection of the missing disc localization. In this report we describe a 32-year-old man who underwent mitral valve replacement with a Tri-technologies bileaflet valve three years ago, and was admitted in cardiogenic shock. Transesophageal echocardiography showed acute-onset massive mitral regurgitation. The patient underwent emergency replacement of the prosthetic valve. Only one of the two leaflets remained in the removed prosthetic valve. The missing leaflet could not be found within the cardiac cavity. The abdominal fluoroscopic study and plain radiography were unable to detect the escaped leaflet. The abdominal computed tomography scan and the ultrasound showed the escaped leaflet in the terminal portion of the aortic bifurcation. To retrieve the embolized disc laparotomy and aortotomy were performed three months later. The escaped leaflet shows a fracture of one of the pivot systems caused by structural failure. This kind of failure mode is usually the result of high stress concentration.

  19. Biomechanics of Artificial Disc Replacements Adjacent to a 2-Level Fusion in 4-Level Hybrid Constructs: An In Vitro Investigation

    Science.gov (United States)

    Liao, Zhenhua; Fogel, Guy R.; Wei, Na; Gu, Hongsheng; Liu, Weiqiang

    2015-01-01

    Background The ideal procedure for multilevel cervical degenerative disc diseases remains controversial. Recent studies on hybrid surgery combining anterior cervical discectomy and fusion (ACDF) and artificial cervical disc replacement (ACDR) for 2-level and 3-level constructs have been reported in the literature. The purpose of this study was to estimate the biomechanics of 3 kinds of 4-level hybrid constructs, which are more likely to be used clinically compared to 4-level arthrodesis. Material/Methods Eighteen human cadaveric spines (C2–T1) were evaluated in different testing conditions: intact, with 3 kinds of 4-level hybrid constructs (hybrid C3–4 ACDR+C4–6 ACDF+C6–7ACDR; hybrid C3–5ACDF+C5–6ACDR+C6–7ACDR; hybrid C3–4ACDR+C4–5ACDR+C5–7ACDF); and 4-level fusion. Results Four-level fusion resulted in significant decrease in the C3–C7 ROM compared with the intact spine. The 3 different 4-level hybrid treatment groups caused only slight change at the instrumented levels compared to intact except for flexion. At the adjacent levels, 4-level fusion resulted in significant increase of contribution of both upper and lower adjacent levels. However, for the 3 hybrid constructs, significant changes of motion increase far lower than 4P at adjacent levels were only noted in partial loading conditions. No destabilizing effect or hypermobility were observed in any 4-level hybrid construct. Conclusions Four-level fusion significantly eliminated motion within the construct and increased motion at the adjacent segments. For all 3 different 4-level hybrid constructs, ACDR normalized motion of the index segment and adjacent segments with no significant hypermobility. Compared with the 4-level ACDF condition, the artificial discs in 4-level hybrid constructs had biomechanical advantages compared to fusion in normalizing adjacent level motion. PMID:26694835

  20. Preliminary and intermediate follow-up outcomes for cervical disc replacement in the treatment of cervical spondylopathy in 12 cases

    International Nuclear Information System (INIS)

    Qian Zhonglai; Yang Huilin; Jiang Weimin; Li Xigong; Li Xuefeng; Tang Tiansi

    2010-01-01

    Objective: To observe the short and intermediate-term clinical outcomes of porous coated motion (PCM) cervical prosthesis in the treatment of cervical spondylosis. Methods: The 12 (13 levels) patients who were suffered spondylotic myelopathy with PCM cervical prosthesis were treated. Evaluate the clinical outcome by comparing the JOA scores, the position of prosthesis,rotation of motion, the heterotopic ossification and Odom's scales. Results: After the average 6.5 months(3 ∼ 12 months) follow-up, the JOA scales raised from 8.35 ± 1.10 preoperatively to 15.88 ± 0.73 postoperatively (P 0.05). There was no occurrence of failures of prosthesis such as subsidence, loosening, or excursion. Heterotopic ossification was also absent. Conclusion: The clinical outcomes for cervical disc replacement in the treatment of cervical spondylopathy are satisfied. (authors)

  1. In-situ photopolymerized and monitored implants: successful application to an intervertebral disc replacement

    Science.gov (United States)

    Schmocker, Andreas M.; Khoushabi, Azadeh; Bourban, Pierre-Etienne; Schizas, Constantin; Pioletti, Dominique; Moser, Christophe

    2016-02-01

    Photopolymerization is a common method to harden materials initially in a liquid state. A surgeon can directly trigger the solidification of a dental implant or a bone or tissue filler by using ultra-violet light. Traditionally, photopolymerization has been used mainly in dentistry. Over the last decade advances in material development including a wide range of biocompatible gel- and cement-systems open up a new avenue for in-situ photopolymerization. We designed a miniaturized light probe where a photoactive material can be 1) mixed, pressurized and injected 2) photopolymerized or photoactivated and 3) monitored during the chemical reaction. The device enables surgeries to be conducted through a hole smaller than 500 μm in diameter. Using a combination of Raman and fluorescence spectroscopy, the current state of the photopolymerization was inferred and monitored in real time within an in-vitro tissue model. It was also possible to determine roughly the position of the probe within the tissue cavity by analysing the fluorescence signal. Using the technique hydrogels were successfully implanted into a bovine intervertebral disc model. Mechanical tests could not obstruct the functionality of the implant. Finally, the device was also used for other application such as the implantation of a hydrogel into an aneurysm tissue cavity which will be presented at the conference.

  2. The value of real-time three-dimensional transesophageal echocardiography in the assessment of paravalvular leak origin following prosthetic mitral valve replacement.

    Science.gov (United States)

    Yildiz, Mustafa; Duran, Nilüfer Ekşi; Gökdeniz, Tayyar; Kaya, Hasan; Ozkan, Mehmet

    2009-09-01

    Two-dimensional (2D) echocardiographic approaches are not sufficient to determine the origin of paravalvular leak (PVL) that occurs after prosthetic mitral valve replacement (MVR). In this study, we investigated the role of real-time three-dimensional transesophageal echocardiography (RT-3D TEE) in detecting the origin and size of PVL occurring after prosthetic MVR. The study included 13 patients (7 females; 6 males; mean age 56+/-10 years; range 37 to 71 years) who developed PVL within a mean of 8.3+/-3.8 years following mechanical prosthetic MVR. Nine patients (69.2%) had atrial fibrillation, and four patients (30.8%) had normal sinus rhythm. Four patients (30.8%) had hemolysis. Paravalvular leak was mild, moderate, and severe in two, six, and five patients, respectively. Real-time 3D TEE was performed using a 3D matrix-array TEE transducer immediately after detection of PVL on 2D TEE examination. Localization of PVL was made using a clock-wise format in relation to the aortic valve and the size of dehiscence was measured. The mean PVL width measured by 2D TEE was 3.00+/-0.92 mm. The mean length of dehiscence was 13.6+/-8.8 mm, and the mean width was 3.88+/-2.04 mm on RT-3D TEE. The PVLs were mainly localized in the posterior and anterior annular positions between 12 to 03 hours (n=7) and 06 to 09 hours (n=3) on RT-3D TEE, respectively, which corresponded to the posteromedial or anterolateral sectors of the posterior annulus. Considering that only the width of the PVL defect can be assessed by 2D TEE, delineation by RT-3D TEE includes the localization of PVL together with the length and width of the defect.

  3. Disc dislodgment in Björk Shiley mitral valve prosthesis: two successfully operated cases.

    Science.gov (United States)

    Dubernet, J; Irarrázaval, M J; Urzúa, J; Maturana, G; Morán, S; Lema, G; Asenjo, F; Fajuri, A

    1986-02-01

    Two patients with Björk Shiley mitral valve replacement had migration and embolization of the occluding disc. One patient suffered migration of the disc a few hours after surgery and the other had a strut fracture with disc translocation six years after the initial operation. Clinical signs in both cases were pulmonary edema, cardiogenic shock, and absence of prosthetic sounds. Both patients were reoperated on an emergency basis, recovering after a complicated postoperative course. They are on functional Class I, 8 and 1 years later, respectively, with their dislodged discs still in the abdominal aorta. The only hope for survival in these patients is emergency reoperation, once the prosthetic mitral valve dysfunction is confirmed.

  4. Quality of systematic reviews: an example of studies comparing artificial disc replacement with fusion in the cervical spine.

    Science.gov (United States)

    Tashani, Osama A; El-Tumi, Hanan; Aneiba, Khaled

    2015-01-01

    Cervical artificial disc replacement (C-ADR) is now an alternative to anterior cervical discectomy and fusion (ACDF). Many studies have evaluated the efficacy of C-ADR compared with ACDF. This led to a series of systematic reviews and meta-analyses to evaluate the evidence of the superiority of one intervention against the other. The aim of the study presented here was to evaluate the quality of these reviews and meta-analyses. Medline via Ovid, Embase, and Cochrane Library were searched using the keywords: (total disk replacement, prosthesis, implantation, discectomy, and arthroplasty) AND (cervical vertebrae, cervical spine, and spine) AND (systematic reviews, reviews, and meta-analysis). Screening and data extraction were conducted by two reviewers independently. Two reviewers then assessed the quality of the selected reviews and meta-analysis using 11-item AMSTAR score which is a validated measurement tool to assess the methodological quality of systematic reviews. Screening of full reports of 46 relevant abstracts resulted in the selection of 15 systematic reviews and/or meta-analyses as eligible for this study. The two reviewers' inter-rater agreement level was high as indicated by kappa of >0.72. The AMSTAR score of the reviews ranged from 3 to 11. Only one study (a Cochrane review) scored 100% (AMSTAR 11). Five studies scored below (AMSTAR 5) indicating low-quality reviews. The most significant drawbacks of reviews of a score below 5 were not using an extensive search strategy, failure to use the scientific quality of the included studies appropriately in formulating a conclusion, not assessing publication bias, and not reporting the excluded studies. With a significant exception of a Cochrane review, the methodological quality of systematic reviews evaluating the evidence of C-ADR versus ACDF has to be improved.

  5. Prosthetic replacement of the medial meniscus in cadaveric knees - Does the prosthesis mimic the functional behavior of the native meniscus?

    NARCIS (Netherlands)

    Tienen, TG; Verdonschot, N; Heijkants, RGJC; Buma, R; Scholten, JGF; van Kampen, A; Veth, RPH

    2004-01-01

    Meniscus replacement by a polymer meniscus prosthesis in dogs resulted in generation of new meniscal tissue. Hypothesis: Optimal functioning of the prosthesis would involve realistic deformation and motion patterns of the prosthesis during knee joint motion. Study Design: Controlled laboratory

  6. Cluster analysis as a method for determining size ranges for spinal implants: disc lumbar replacement prosthesis dimensions from magnetic resonance images.

    Science.gov (United States)

    Lei, Dang; Holder, Roger L; Smith, Francis W; Wardlaw, Douglas; Hukins, David W L

    2006-12-01

    Statistical analysis of clinical radiologic data. To develop an objective method for finding the number of sizes for a lumbar disc replacement. Cluster analysis is a well-established technique for sorting observations into clusters so that the "similarity level" is maximal if they belong to the same cluster and minimal otherwise. Magnetic resonance scans from 69 patients, with no abnormal discs, yielded 206 sagittal and transverse images of 206 discs (levels L3-L4-L5-S1). Anteroposterior and lateral dimensions were measured from vertebral margins on transverse images; disc heights were measured from sagittal images. Hierarchical cluster analysis was performed to determine the number of clusters followed by nonhierarchical (K-means) cluster analysis. Discriminant analysis was used to determine how well the clusters could be used to classify an observation. The most successful method of clustering the data involved the following parameters: anteroposterior dimension; lateral dimension (both were the mean of results from the superior and inferior margins of a vertebral body, measured on transverse images); and maximum disc height (from a midsagittal image). These were grouped into 7 clusters so that a discriminant analysis was capable of correctly classifying 97.1% of the observations. The mean and standard deviations for the parameter values in each cluster were determined. Cluster analysis has been successfully used to find the dimensions of the minimum number of prosthesis sizes required to replace L3-L4 to L5-S1 discs; the range of sizes would enable them to be used at higher lumbar levels in some patients.

  7. Lumbar total disc replacement from an extreme lateral approach: clinical experience with a minimum of 2 years' follow-up.

    Science.gov (United States)

    Pimenta, Luiz; Oliveira, Leonardo; Schaffa, Thomas; Coutinho, Etevaldo; Marchi, Luis

    2011-01-01

    current lumbar total disc replacement (TDR) devices require an anterior approach for implantation. This approach has inherent limitations, including risks to abdominal structures and the need for resection of the anterior longitudinal ligament (ALL). Placement of a TDR device from a true lateral (extreme lateral interbody fusion [XLIF]) approach is thought to offer a less invasive option to access the disc space, preserving the stabilizing ligaments and avoiding scarring of anterior vasculature. In this study, the authors attempted to quantify the clinical and radiographic outcomes of a lateral approach to lumbar TDR from a prospective, single-center experience. a TDR device designed for implantation through a true lateral, retroperitoneal, transpsoas approach (XLIF) was implanted in 36 patients with discography-confirmed 1- or 2-level degenerative disc disease. Clinical (pain and function) and radiographic (range of motion [ROM]) data were prospectively collected preoperatively, postoperatively, and serially for a minimum of 24 months' follow-up. thirty-six surgeries were performed in 16 men and 20 women (mean age 42.6 years). Surgeries included 15 single-level TDR procedures at L3-4 or L4-5, three 2-level TDR procedures spanning L3-4 and L4-5, and 18 hybrid procedures (anterior lumbar interbody fusion [ALIF]) at L5-S1 and TDR at L4-5 [17] or L3-4 [1]). Operative time averaged 130 minutes, with an average blood loss of 60 ml and no intraoperative complications. Postoperative radiographs showed good device placement. All patients were walking within 12 hours of surgery and all but 9 were discharged the next day (7 of 9 had hybrid TDR/ALIF procedures). Five patients (13.8%) had psoas weakness and 3 (8.3%) had anterior thigh numbness postoperatively, both resolving within 2 weeks. One patient (2.8%) demonstrated weakness of the leg ipsilateral to the approach side, which lasted through the 3-month visit but was resolved by the 6-month visit. One patient (2.8%) was

  8. Dual energy X-ray absorptiometry analysis of peri-prosthetic stress shielding in the Birmingham resurfacing hip replacement.

    LENUS (Irish Health Repository)

    Harty, J A

    2012-02-03

    INTRODUCTION: Numerous reports in the literature refer to the femoral neck fracture rate in hip resurfacing. The aim of this study was to determine the bone mineral density and evidence of stress shielding around the femoral component of the Birmingham resurfacing prosthesis. MATERIAL AND METHODS: Twenty-eight patients with primary unilateral osteoarthritis had a Birmingham resurfacing prosthesis. DEXA analysis of the proximal femur and femoral neck was performed and compared with the opposite unaffected side. RESULTS: Total periprosthetic bone mineral density was 0.49% greater than the control, but this did not achieve statistical significance. Although the BMD of the femoral neck was slightly increased on the prosthetic side (1.002 g\\/cm2) as opposed to the control side, this difference did not reach statistical significance. CONCLUSION: The Birmingham resurfacing prosthesis does not appear to reduce femoral neck bone mineral density in comparison to the normal femoral neck bone density. We conclude that femoral neck fractures are unlikely to be due to stress shielding related to the prosthesis.

  9. Evaluation of Adverse Events in Total Disc Replacement: A Meta-Analysis of FDA Summary of Safety and Effectiveness Data.

    Science.gov (United States)

    Anderson, Paul A; Nassr, Ahmad; Currier, Bradford L; Sebastian, Arjun S; Arnold, Paul M; Fehlings, Michael G; Mroz, Thomas E; Riew, K Daniel

    2017-04-01

    Systematic review and meta-analysis. The safety of new technology such as cervical total disc replacement (TDR) is of paramount importance and is best evaluated in randomized clinical trials (RCT). We compared complication risks of TDR to fusion using data from Investigational Device Exemptions. A systematic review of FDA Summary of Safety and Effectiveness reports of the 8 approved cervical TDRs was performed. These were all randomized controlled trials comparing anterior cervical discectomy and fusion (ACDF) to TDR. Important outcome variables were dysphagia, wound infection, neurologic injuries, heterotopic ossification, death, and secondary surgeries. A random effects model was selected a priori. Data on adverse events was abstracted and analyzed by calculating relative risk of ACDF to TDR by meta-analysis techniques. The study included 3027 patients with 1377 randomized to ACDF and 1652 to TDR. No statistical differences were present between the 2 groups in dysphagia/dysphonia, hardware related, heterotopic ossification, death, and overall neurologic adverse events and incidence of neurologic deterioration. The relative risk of wound-related problems ACDF to TDR was 0.76 (95% confidence interval [CI] = 0.59, 0.98) favoring ACDF, which was statistically significant, but these were minor and never required a second surgical procedure for deep wound infection. The relative risk of ACDF to TDR in surgical-related neurologic events and secondary surgeries was 1.62 (95% CI = 1.04, 2.53) and 1.79 (95% CI = 1.17, 2.74), both favoring TDR. Cervical TDR appears to be as safe as or safer than ACDF at 2-year follow-up.

  10. Guide to prosthetic cardiac valves

    International Nuclear Information System (INIS)

    Morse, D.; Steiner, R.M.; Fernandez, J.

    1985-01-01

    This book contains 10 chapters. Some of the chapter titles are: The development of artificial heart valves: Introduction and historical perspective; The radiology of prosthetic heart valves; The evaluation of patients for prosthetic valve implantation; Pathology of cardiac valve replacement; and Bioengineering of mechanical and biological heart valve substitutes

  11. Evidence for cell-replacement repair of X-ray-induced teratogenic damage in male genital imaginal discs of Drosophila melanogaster

    International Nuclear Information System (INIS)

    Fukunaga, Akihiro; Kondo, Sohei

    1985-01-01

    Male genital imaginal discs from old (late-third-instar) larvae of Drosophila that had been X-irradiated with appropriate doses developed into severely damaged adult genitalia when implanted into old larvae, but they developed into completely normal adult genitalia when transplanted into 2-day-younger larvae. Complete repair of X-ray-induced teratogenic damage in the genital discs on transplantation into young host larvae was similar in the wild-type and mei-9sup(a) strains. The results are discussed in relation to the hypothesis that repair of X-ray-induced teratogenic damage depends not on DNA repair but on replacement of damage-bearing primordial cells by healthy ones after suicidal elimination of the former. (Auth.)

  12. Biomechanics of Hybrid Anterior Cervical Fusion and Artificial Disc Replacement in 3-Level Constructs: An In Vitro Investigation

    Science.gov (United States)

    Liao, Zhenhua; Fogel, Guy R.; Pu, Ting; Gu, Hongsheng; Liu, Weiqiang

    2015-01-01

    Background The ideal surgical approach for cervical disk disease remains controversial, especially for multilevel cervical disease. The purpose of this study was to investigate the biomechanics of the cervical spine after 3-level hybrid surgery compared with 3-level anterior cervical discectomy and fusion (ACDF). Material/Methods Eighteen human cadaveric spines (C2-T1) were evaluated under displacement-input protocol. After intact testing, a simulated hybrid construct or fusion construct was created between C3 to C6 and tested in the following 3 conditions: 3-level disc plate disc (3DPD), 3-level plate disc plate (3PDP), and 3-level plate (3P). Results Compared to intact, almost 65~80% of motion was successfully restricted at C3-C6 fusion levels (p0.05). 3PDP construct resulted in significant decrease of ROM at C3-C6 levels less than 3P (pbiomechanical advantages compared to fusion in normalizing motion. PMID:26529430

  13. The 5-year cost-effectiveness of two-level anterior cervical discectomy and fusion or cervical disc replacement: a Markov analysis.

    Science.gov (United States)

    Overley, Samuel C; McAnany, Steven J; Brochin, Robert L; Kim, Jun S; Merrill, Robert K; Qureshi, Sheeraz A

    2018-01-01

    Anterior cervical discectomy and fusion (ACDF) and cervical disc replacement (CDR) are both acceptable surgical options for the treatment of cervical myelopathy and radiculopathy. To date, there are limited economic analyses assessing the relative cost-effectiveness of two-level ACDF versus CDR. The purpose of this study was to determine the 5-year cost-effectiveness of two-level ACDF versus CDR. The study design is a secondary analysis of prospectively collected data. Patients in the Prestige cervical disc investigational device exemption (IDE) study who underwent either a two-level CDR or a two-level ACDF were included in the study. The outcome measures were cost and quality-adjusted life years (QALYs). A Markov state-transition model was used to evaluate data from the two-level Prestige cervical disc IDE study. Data from the 36-item Short Form Health Survey were converted into utilities using the short form (SF)-6D algorithm. Costs were calculated from the payer perspective. QALYs were used to represent effectiveness. A probabilistic sensitivity analysis (PSA) was performed using a Monte Carlo simulation. The base-case analysis, assuming a 40-year-old person who failed appropriate conservative care, generated a 5-year cost of $130,417 for CDR and $116,717 for ACDF. Cervical disc replacement and ACDF generated 3.45 and 3.23 QALYs, respectively. The incremental cost-effectiveness ratio (ICER) was calculated to be $62,337/QALY for CDR. The Monte Carlo simulation validated the base-case scenario. Cervical disc replacement had an average cost of $130,445 (confidence interval [CI]: $108,395-$152,761) with an average effectiveness of 3.46 (CI: 3.05-3.83). Anterior cervical discectomy and fusion had an average cost of $116,595 (CI: $95,439-$137,937) and an average effectiveness of 3.23 (CI: 2.84-3.59). The ICER was calculated at $62,133/QALY with respect to CDR. Using a $100,000/QALY willingness to pay (WTP), CDR is the more cost-effective strategy and would be selected

  14. Preoperative irradiation for prevention of heterotopic ossification following prosthetic total hip replacement. Results of a prospective study in 462 hips

    Energy Technology Data Exchange (ETDEWEB)

    Koelbl, O.; Seufert, J.; Pohl, F.; Flentje, M. [Univ. Wuerzburg (Germany). Klinik and Poliklinik for Radiotherapy; Tauscher, A.; Springorum, H.W. [Caritas Hospital, Bad Mergentheim (Germany). Orthopedic Clinic; Lehmann, H. [Caritas Hospital, Bad Mergentheim (Germany). Inst. of Radiology

    2003-11-01

    Background: The effectiveness of pre- or postoperative radiotherapy for prevention of heterotopic ossification (HO) following total hip replacement (THR) has already been demonstrated in the past. Thereby, in most studies using preoperative radiotherapy patients were irradiated < 6 h before surgery. The purpose of this prospective study was to analyze the effectiveness of preoperative irradiation on the evening before surgery and to identify risk factors for HO in a homogeneous collective of patients. Patients and Methods: From July 1997 to July 2001, 416 patients (462 hips; 235 males, 227 females) received preoperative radiotherapy of the hip on the evening before surgery with a 7-Gy single fraction. The patients' median age was 67.1 years. The most frequent indication for radiotherapy was hypertrophic osteoarthritis (383 hips, 82.9%). Treatment results were assessed by comparison of pre- and postoperative hip X-rays (immediately and 6 months after surgery). The analysis of radiographs was performed according to the Brooker score. Results: The overall incidence of HO was 18.1% (n = 84), Brooker score 1 12.3% (n = 57), score 2 3.9% (n = 18), score 3 1.5% (n = 7), and score 4 0.4% (n = 2). Sex, body height, hypertrophic osteoarthritis of higher degree, size of the femoral component of the prosthesis, previous ipsi- or contralateral HO, and short course of nonsteroidal anti-inflammatory drug (diclofenac) therapy significantly influenced the HO rate in univariate analysis. In multivariate analysis, an interdependence of prosthesis size, sex and patient's height was found. From these three variables, only prosthesis size was statistically significant in multivariate analysis. The cumulative dose of diclofenac ({<=} 300 mg or > 300 mg) within the first 7 postoperative days and previous ipsi- or contralateral HO influenced the incidence of HO in multivariate analysis. Conclusion: Preoperative radiotherapy on the evening before surgery is an effective treatment

  15. Patient-reported Outcomes and Revision Rates at a Mean Follow-up of 10 Years After Lumbar Total Disc Replacement

    DEFF Research Database (Denmark)

    Laugesen, Line A.; Tendal Paulsen, Rune; Carreon, Leah

    2017-01-01

    STUDY DESIGN.: Prospective observational cohort study. OBJECTIVE.: To determine the long-term clinical results and prosthesis survival in patients treated with lumbar total disc replacement (TDR). SUMMARY OF BACKGROUND DATA.: Fusion has become the current standard surgical treatment for lumbar...... and statistically significant worse outcome scores at last follow-up compared to patients who had no revision. Thirty patients (52.6%) would choose the same treatment again if they were faced with the same problem. CONCLUSION.: This study demonstrated significant improvement in long-term clinical outcomes, similar...

  16. Prosthetic alignment after total knee replacement is not associated with dissatisfaction or change in Oxford Knee Score: A multivariable regression analysis.

    Science.gov (United States)

    Huijbregts, Henricus J T A M; Khan, Riaz J K; Fick, Daniel P; Jarrett, Olivia M; Haebich, Samantha

    2016-06-01

    Approximately 18% of the patients are dissatisfied with the result of total knee replacement. However, the relation between dissatisfaction and prosthetic alignment has not been investigated before. We retrospectively analysed prospectively gathered data of all patients who had a primary TKR, preoperative and one-year postoperative Oxford Knee Scores (OKS) and postoperative computed tomography (CT). The CT protocol measures hip-knee-ankle (HKA) angle, and coronal, sagittal and axial component alignment. Satisfaction was defined using a five-item Likert scale. We dichotomised dissatisfaction by combining '(very) dissatisfied' and 'neutral/not sure'. Associations with dissatisfaction and change in OKS were calculated using multivariable logistic and linear regression models. 230 TKRs were implanted in 105 men and 106 women. At one year, 12% were (very) dissatisfied and 10% neutral. Coronal alignment of the femoral component was 0.5 degrees more accurate in patients who were satisfied at one year. The other alignment measurements were not different between satisfied and dissatisfied patients. All radiographic measurements had a P-value>0.10 on univariate analyses. At one year, dissatisfaction was associated with the three-months OKS. Change in OKS was associated with three-months OKS, preoperative physical SF-12, preoperative pain and cruciate retaining design. Neither mechanical axis, nor component alignment, is associated with dissatisfaction at one year following TKR. Patients get the best outcome when pain reduction and function improvement are optimal during the first three months and when the indication to embark on surgery is based on physical limitations rather than on a high pain score. 2. Copyright © 2016 Elsevier B.V. All rights reserved.

  17. Five-year decreased incidence of surgical site infections following gastrectomy and prosthetic joint replacement surgery through active surveillance by the Korean Nosocomial Infection Surveillance System.

    Science.gov (United States)

    Choi, H J; Adiyani, L; Sung, J; Choi, J Y; Kim, H B; Kim, Y K; Kwak, Y G; Yoo, H; Lee, Sang-Oh; Han, S H; Kim, S R; Kim, T H; Lee, H M; Chun, H K; Kim, J-S; Yoo, J D; Koo, H-S; Cho, E H; Lee, K W

    2016-08-01

    Surveillance of healthcare-associated infection has been associated with a reduction in surgical site infection (SSI). To evaluate the Korean Nosocomial Infection Surveillance System (KONIS) in order to assess its effects on SSI since it was introduced. SSI data after gastrectomy, total hip arthroplasty (THA), and total knee arthroplasty (TKA) between 2008 and 2012 were analysed. The pooled incidence of SSI was calculated for each year; the same analyses were also conducted from hospitals that had participated in KONIS for at least three consecutive years. Standardized SSI rates for each year were calculated by adjusting for SSI risk factors. SSI trends were analysed using the Cochran-Armitage test. The SSI rate following gastrectomy was 3.12% (522/16,918). There was a significant trend of decreased crude SSI rates over five years. This trend was also evident in analysis of hospitals that had participated for more than three years. The SSI rate for THA was 2.05% (157/7656), which decreased significantly from 2008 to 2012. The risk factors for SSI after THA included the National Nosocomial Infections Surveillance risk index, trauma, reoperation, and age (60-69 years). The SSI rate for TKA was 1.90% (152/7648), which also decreased significantly during a period of five years. However, the risk-adjusted analysis of SSI did not show a significant decrease for all surgical procedures. The SSI incidence of gastrectomy and prosthetic joint replacement declined over five years as a result of active surveillance by KONIS. Copyright © 2016 The Healthcare Infection Society. Published by Elsevier Ltd. All rights reserved.

  18. The Discover artificial disc replacement versus fusion in cervical radiculopathy--a randomized controlled outcome trial with 2-year follow-up.

    Science.gov (United States)

    Skeppholm, Martin; Lindgren, Lars; Henriques, Thomas; Vavruch, Ludek; Löfgren, Håkan; Olerud, Claes

    2015-06-01

    Several previous studies comparing artificial disc replacement (ADR) and fusion have been conducted with cautiously positive results in favor of ADR. This study is not, in contrast to most previous studies, an investigational device exemption study required by the Food and Drug Administration for approval to market the product in the United States. This study was partially funded with unrestricted institutional research grants by the company marketing the artificial disc used in this study. To compare outcomes between the concepts of an artificial disc to treatment with anterior cervical decompression and fusion (ACDF) and to register complications associated to the two treatments during a follow-up time of 2 years. This is a randomized controlled multicenter trial, including three spine centers in Sweden. The study included patients seeking care for cervical radiculopathy who fulfilled inclusion criteria. In total, 153 patients were included. Self-assessment with Neck Disability Index (NDI) as a primary outcome variable and EQ-5D and visual analog scale as secondary outcome variables. Patients were randomly allocated to either treatment with the Depuy Discover artificial disc or fusion with iliac crest bone graft and plating. Randomization was blinded to both patient and caregivers until time for implantation. Adverse events, complications, and revision surgery were registered as well as loss of follow-up. Data were available in 137 (91%) of the included and initially treated patients. Both groups improved significantly after surgery. NDI changed from 63.1 to 39.8 in an intention-to-treat analysis. No statistically significant difference between the ADR and the ACDF groups could be demonstrated with NDI values of 39.1 and 40.1, respectively. Nor in secondary outcome measures (EQ-5D and visual analog scale) could any statistically significant differences be demonstrated between the groups. Nine patients in the ADR group and three in the fusion group underwent

  19. Comparative Study Between M6-C and Mobi-C Cervical Artificial Disc Replacement: Biomechanical Outcomes and Comparison with Normative Data.

    Science.gov (United States)

    Pham, My; Phan, Kevin; Teng, Ian; Mobbs, Ralph J

    2018-05-01

    Cervical spondylosis affects a huge proportion of the middle-aged population. Degenerative changes can occur in multiple regions of the cervical spine typically affecting the joints, intervertebral discs and endplates. These changes lead to compression of adjacent nervous structures, which results in radiculopathic and myelopathic pain. Various treatment modalities are currently available with non-surgical approaches the initial go to if there is no symptomatic cord compression. Anterior cervical discectomy and fusion, or arthroplasty are the two common surgical approaches if non-surgical treatments fail to relieve symptoms of the patients or there are signs of central cord compression. However, studies have shown that there is an increased risk of adjacent segment disease related to fusion. Cervical disc arthroplasty aims to restore normal range of motion (ROM) in patients with pain and disability due to degenerative disc disease resistant to conservative care. Two common disc prostheses used include M6-C and Mobi-C. Both prostheses comprise a mobile polymer segment sandwiched between two metal endplates with mechanisms resembling an actual intervertebral disc. This study aims to compare the kinematics associated with these prostheses, against the normal range of motion in the non-degenerative population. Patients who underwent M6-C or Mobi-C disc replacements by the senior author from 2012 to 2015 were identified at a single tertiary institution. Routine 3-month postoperative lateral radiographs were analyzed for flexion and extension ROM angles at the involved vertebral level by two independent authors. Data was compared to previous published studies investigating cervical spine ROM of asymptomatic patients. There was no statistical significance in the difference of overall flexion range between M6-C and Mobi-C prostheses. However, overall range of extension of Mobi-C was greater compared to M6-C (P = 0.028). At C 5-6 , the range of flexion for both implants

  20. Complications of Lumbar Artificial Disc Replacement Compared to Fusion: Results From the Prospective, Randomized, Multicenter US Food and Drug Administration Investigational Device Exemption Study of the Charité Artificial Disc

    Science.gov (United States)

    Majd, Mohammed E.; Isaza, Jorge E.; Blumenthal, Scott L.; McAfee, Paul C.; Guyer, Richard D.; Hochschuler, Stephen H.; Geisler, Fred H.; Garcia, Rolando; Regan, John J.

    2007-01-01

    Background Previous reports of lumbar total disc replacement (TDR) have described significant complications. The US Food and Drug Administration (FDA) investigational device exemption (IDE) study of the Charité artificial disc represents the first level I data comparison of TDR to fusion. Methods In the prospective, randomized, multicenter IDE study, patients were randomized in a 2:1 ratio, with 205 patients in the Charité group and 99 patients in the control group (anterior lumbar interbody fusion [ALIF] with BAK cages). Inclusion criteria included confirmed single-level degenerative disc disease at L4-5 or L5-S1 and failure of nonoperative treatment for at least 6 months. Complications were reported throughout the study. Results The rate of approach-related complications was 9.8% in the investigational group and 10.1% in the control group. The rate of major neurological complications was similar between the 2 groups (investigational = 4.4%, control = 4.0%). There was a higher rate of superficial wound infection in the investigational group but no deep wound infections in either group. Pseudarthrosis occurred in 9.1% of control group patients. The rate of subsidence in the investigational group was 3.4%. The reoperation rate was 5.4% in the investigational group and 9.1% in the control group. Conclusions The incidence of perioperative and postoperative complications for lumbar TDR was similar to that of ALIF. Vigilance is necessary with respect to patient indications, training, and correct surgical technique to maintain TDR complications at the levels experienced in the IDE study. PMID:25802575

  1. Complete Transversal Disc Fracture in a Björk-Shiley Delrin Mitral Valve Prosthesis 43 Years After Implantation.

    Science.gov (United States)

    González-Santos, Jose María; Arnáiz-García, María Elena; Dalmau-Sorlí, María José; Sastre-Rincón, Jose Alfonso; Hernández-Hernández, Jesús; Pérez-Losada, María Elena; Sagredo-Meneses, Víctor; López-Rodríguez, Javier

    2016-10-01

    A patient who underwent previous implantation of a mitral valve replacement with a Björk-Shiley Delrin (BSD) mitral valve prosthesis during infancy was admitted to our institution 43 years later after an episode of syncope and cardiac arrest. Under extreme hemodynamic instability, a mitral valve prosthetic dysfunction causing massive mitral regurgitation was identified. The patient underwent an emergent cardiac operation, and a complete disc fracture with partial disc migration was found. Exceptional cases of mechanical prosthetic heart valve fracture exist. We report the first case of complete transversal disc rupture of a BSD mitral valve prosthesis after the longest period of implantation ever reported in that position. Copyright © 2016 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

  2. Comparative Analysis between Total Disc Replacement and Posterior Foraminotomy for Posterolateral Soft Disc Herniation with Unilateral Radiculopathy : Clinical and Biomechanical Results of a Minimum 5 Years Follow-up

    Science.gov (United States)

    Kim, Kyoung-Tae; Cho, Dae-Chul; Sung, Joo-Kyung; Kim, Young-Baeg; Kim, Du Hwan

    2017-01-01

    Objective To compare the clinical outcomes and biomechanical effects of total disc replacement (TDR) and posterior cervical foraminotomy (PCF) and to propose relative inclusion criteria. Methods Thirty-five patients who underwent surgery between 2006 and 2008 were included. All patients had single-level disease and only radiculopathy. The overall sagittal balance and angle and height of a functional segmental unit (FSU; upper and lower vertebral body of the operative lesion) were assessed by preoperative and follow-up radiographs. C2–7 range of motion (ROM), FSU, and the adjacent segment were also checked. Results The clinical outcome of TDR (group A) was tended to be superior to that of PCF (group B) without statistical significance. In the group A, preoperative and postoperative upper adjacent segment level motion values were 8.6±2.3 and 8.4±2.0, and lower level motion values were 8.4±2.2 and 8.3±1.9. Preoperative and postoperative FSU heights were 37.0±2.1 and 37.1±1.8. In the group B, upper level adjacent segment motion values were 8.1±2.6 and 8.2±2.8, and lower level motion values were 6.5±3.3 and 6.3±3.1. FSU heights were 37.1±2.0 and 36.2±1.8. The postoperative FSU motion and height changes were significant (p<0.05). The patient’s satisfaction rates for surgery were 88.2% in group A and 88.8% in group B. Conclusion TDR and PCF have favorable outcomes in patients with unilateral soft disc herniation. However, patients have different biomechanical backgrounds, so the patient’s biomechanical characteristics and economic status should be understood and treated using the optimal procedure. PMID:28061490

  3. Replacement

    Directory of Open Access Journals (Sweden)

    S. Radhakrishnan

    2014-03-01

    Full Text Available The fishmeal replaced with Spirulina platensis, Chlorella vulgaris and Azolla pinnata and the formulated diet fed to Macrobrachium rosenbergii postlarvae to assess the enhancement ability of non-enzymatic antioxidants (vitamin C and E, enzymatic antioxidants (superoxide dismutase (SOD and catalase (CAT and lipid peroxidation (LPx were analysed. In the present study, the S. platensis, C. vulgaris and A. pinnata inclusion diet fed groups had significant (P < 0.05 improvement in the levels of vitamins C and E in the hepatopancreas and muscle tissue. Among all the diets, the replacement materials in 50% incorporated feed fed groups showed better performance when compared with the control group in non-enzymatic antioxidant activity. The 50% fishmeal replacement (best performance diet fed groups taken for enzymatic antioxidant study, in SOD, CAT and LPx showed no significant increases when compared with the control group. Hence, the present results revealed that the formulated feed enhanced the vitamins C and E, the result of decreased level of enzymatic antioxidants (SOD, CAT and LPx revealed that these feeds are non-toxic and do not produce any stress to postlarvae. These ingredients can be used as an alternative protein source for sustainable Macrobrachium culture.

  4. Iodine-125 orbital brachytherapy with a prosthetic implant in situ

    Energy Technology Data Exchange (ETDEWEB)

    Stannard, Clare [Groote Schuur Hospital and Cape Town Univ. (South Africa). Dept. of Radiation Oncology; Maree, Gert; Munro, Roger [Groote Schuur Hospital and Cape Town Univ. (South Africa). Dept. of Medical Physics; Lecuona, Karin [Groote Schuur Hospital and Cape Town Univ. (South Africa). Dept. of Ophthalmology; Sauerwein, Wolfgang [Universitaetsklinikum Essen (Germany). Strahlenklinik, NCTeam

    2011-05-15

    Purpose: Brachytherapy is one method of irradiating the orbit after enucleation of an eye with a malignant tumor that has a potential to recur. It consists of 6 trains of I-125 seeds placed around the periphery of the orbit, a shorter central train, and a metal disc, loaded with seeds, placed beneath the eyelids. The presence of a prosthetic orbital implant requires omission of the central train and adjustment of the activity of the seeds in the anterior orbit around the prosthesis. Patients and Methods: This is a retrospective review of the technical modifications and outcome of 12 patients treated in this manner: 6 with retinoblastoma, 5 with malignant melanoma, and 1 with an intraocular rhabdomyosarcoma. The median dose was 35.5 Gy in 73 hours for retinoblastoma and 56 Gy in 141 hours for malignant melanoma. Patients with retinoblastoma and rhabdomyosarcoma also received chemotherapy. Results: The tubes can be placed satisfactorily around the prosthesis. The increased activity in the anterior half of the tubes produced comparable dose distributions. There have been no orbital recurrences, no extrusion of the prosthesis, and cosmesis is good. Conclusion: Insertion of a prosthetic implant at the time of enucleation greatly enhances the subsequent cosmetic appearance. This should be encouraged unless there is frank tumor in the orbit. Orbital brachytherapy without the central train continues to give excellent local control. The short treatment time and good cosmesis are added advantages. The patient is spared the expense and inconvenience of removing and replacing the prosthetic implant. (orig.)

  5. Prosthetic Engineering

    Science.gov (United States)

    ... the household and community environments may lead to falls and injuries. This research aims to develop an ankle that can invert and evert and thereby control the center of pressure under the prosthetic foot; enhancing balance and stability of lower limb amputees. Foot-Ankle ...

  6. Prosthetics in Paediatric Dentistry

    Directory of Open Access Journals (Sweden)

    Vulićević Zoran

    2017-07-01

    Full Text Available Premature loss of teeth in children may lead to both functional and esthetic problems. Missing teeth in both anterior and posterior regions may cause malfunctions in mastication and proper pronunciation. If the missing teeth are not replaced, further complications may occur, including adjacent tooth migration, loss of alveolar bone, and irregular occlusion. Considering the sensitive nature of children, loss of teeth may cause the development of insecurities and low self esteem problems. Due to dynamic nature of growth in children and adolescents, prosthetic appliances must not hinder development of orofacial system, and must meet adequate esthetic and functional standards. Dental prosthetic appliances in paediatrics must be planned with respect to the special conditions that led to tooth loss or damage. Multi-disciplinary approach is needed, under constant supervision of paediatric dentist and orthodontist, as well as regular checkups with clinical and radiographical examinations.

  7. Isolated mitral valve replacement with the Kay-Shiley disc. valve. Acturial analysis of the long term results.

    Science.gov (United States)

    Wellons, H A; Strauch, R S; Nolan, S P; Muller, W H

    1975-11-01

    During a five-year period the Kay-Shiley (K and T series) prosthesis was used for 83 isolated mitral valve replacements. There were 14 early deaths, for a 17.28 per cent mortality rate. Survival determined by the actuarial method revealed a 6 year cumulative survival rate of 39.8 per cent. Thromboembolism was a significant problem in this series, with 33 patients experiencing a total of 55 embolic events. This represented a rate of 24.7 emboli per 1,000 patient months at risk. From our experience, it is concluded that the Kay-Shiley prosthesis is associated with a high incidence of thromboembolism and late death.

  8. Comparison of the incidence of patient-reported post-operative dysphagia between ACDF with a traditional anterior plate and artificial cervical disc replacement.

    Science.gov (United States)

    Yang, Yi; Ma, Litai; Liu, Hao; Liu, Yilian; Hong, Ying; Wang, Beiyu; Ding, Chen; Deng, Yuxiao; Song, Yueming; Liu, Limin

    2016-09-01

    Compared with anterior cervical discectomy and fusion (ACDF), cervical disc replacement (CDR) has provided satisfactory clinical results. The incidence of post-operative dysphagia between ACDF with a traditional anterior plate and CDR remains controversial. Considering the limited studies and knowledge in this area, a retrospective study focusing on post-operative dysphagia was conducted. The Bazaz grading system was used to assess the severity of dysphagia at post-operative intervals including 1 week, 1 month, 3 months, 6 months, 12 months and 24 months respectively. The Chi-square test, Student t-test, Mann-Whitney U tests and Ordinal Logistic regression were used for data analysis when appropriate. Statistical significance was accepted at a probability value of dysphagia in the CDR and plate group were 36.58% and 60.43% at one week, 29.27% and 38.85% at one month, 21.95% and 31.65% at three months, 6.83% and 17.99% at six months, 5.85% and 14.39% at 12 months, and 4.39% and 10.07% at the final follow-up respectively (All Pdysphagia (all Pdysphagia. Female patients, two-level surgery, C4/5 surgery and anterior cervical plating were associated with a higher incidence of dysphagia. Future prospective, randomized, controlled studies are needed to further validate these findings. Copyright © 2016 Elsevier B.V. All rights reserved.

  9. Prosthetic management of deciduous teeth

    OpenAIRE

    Bassil, Jean

    2015-01-01

    Projeto de Pós-Graduação/Dissertação apresentado à Universidade Fernando Pessoa como parte dos requisitos para obtenção do grau de Mestre em Medicina Dentária Introduction: Situations of single or multiple edentulous are not an exception during childhood. Prosthetic management is necessary in case of absence of replacing tooth or when its eruption is planned too far in time. Indications of prosthetic rehabilitation for children are multiple and rise from the etiologic factors caus...

  10. Anaerobic prosthetic joint infection.

    Science.gov (United States)

    Shah, Neel B; Tande, Aaron J; Patel, Robin; Berbari, Elie F

    2015-12-01

    In an effort to improve mobility and alleviate pain from degenerative and connective tissue joint disease, an increasing number of individuals are undergoing prosthetic joint replacement in the United States. Joint replacement is a highly effective intervention, resulting in improved quality of life and increased independence [1]. By 2030, it is predicted that approximately 4 million total hip and knee arthroplasties will be performed yearly in the United States [2]. One of the major complications associated with this procedure is prosthetic joint infection (PJI), occurring at a rate of 1-2% [3-7]. In 2011, the Musculoskeletal Infectious Society created a unifying definition for prosthetic joint infection [8]. The following year, the Infectious Disease Society of America published practice guidelines that focused on the diagnosis and management of PJI. These guidelines focused on the management of commonly encountered organisms associated with PJI, including staphylococci, streptococci and select aerobic Gram-negative bacteria. However, with the exception of Propionibacterium acnes, management of other anaerobic organisms was not addressed in these guidelines [1]. Although making up approximately 3-6% of PJI [9,10], anaerobic microorganisms cause devastating complications, and similar to the more common organisms associated with PJI, these bacteria also result in significant morbidity, poor outcomes and increased health-care costs. Data on diagnosis and management of anaerobic PJI is mostly derived from case reports, along with a few cohort studies [3]. There is a paucity of published data outlining factors associated with risks, diagnosis and management of anaerobic PJI. We therefore reviewed available literature on anaerobic PJI by systematically searching the PubMed database, and collected data from secondary searches to determine information on pathogenesis, demographic data, clinical features, diagnosis and management. We focused our search on five commonly

  11. Three-year hemodynamic performance, left ventricular mass regression, and prosthetic-patient mismatch after rapid deployment aortic valve replacement in 287 patients.

    Science.gov (United States)

    Haverich, Axel; Wahlers, Thorsten C; Borger, Michael A; Shrestha, Malakh; Kocher, Alfred A; Walther, Thomas; Roth, Matthias; Misfeld, Martin; Mohr, Friedrich W; Kempfert, Joerg; Dohmen, Pascal M; Schmitz, Christoph; Rahmanian, Parwis; Wiedemann, Dominik; Duhay, Francis G; Laufer, Günther

    2014-12-01

    Superior aortic valve hemodynamic performance can accelerate left ventricular mass regression and enhance survival and functional status after surgical aortic valve replacement. This can be achieved by rapid deployment aortic valve replacement using a subannular balloon-expandable stent frame, which functionally widens and reshapes the left ventricular outflow tract, to ensure a larger effective orifice area compared with conventional surgical valves. We report the intermediate-term follow-up data from a large series of patients enrolled in the Surgical Treatment of Aortic Stenosis With a Next Generation Surgical Aortic Valve (TRITON) trial. In a prospective, multicenter (6 European hospitals), single-arm study, 287 patients with aortic stenosis underwent rapid deployment aortic valve replacement using a stented trileaflet bovine pericardial bioprosthesis. Core laboratory echocardiography was performed at baseline, discharge, and 3 months, 1 year, and 3 years after rapid deployment aortic valve replacement. The mean patient age was 75.7 ± 6.7 years (range, 45-93; 49.1% women). The mean aortic valve gradient significantly decreased from discharge to 3 years of follow-up. The mean effective orifice area remained stable from discharge to 3 years. At 1 year, the left ventricular mass index had decreased by 14% (P replacement using a subannular balloon-expandable stent frame demonstrated excellent hemodynamic performance and significant left ventricular mass regression. With continued follow-up, future studies will establish whether these favorable structural changes correlate with improvement in long-term survival and functional status. Copyright © 2014 The American Association for Thoracic Surgery. Published by Elsevier Inc. All rights reserved.

  12. Prosthetic Management of Patients Presenting with Juvenile ...

    African Journals Online (AJOL)

    Eighteen were referred for prosthetic replacement. Their age ranged between 18 and 36 years. A total of 24 removable partial dentures were fabricated, 17[70.8%] were kennedy class III type, of which 11[64.7%] had the bounded saddle located in the anterior segment. Majority 8[44.4%] of the patients had 2-4 teeth replaced ...

  13. 99mTc-HMPAO labeled leucocyte, 99mTc-labeled antigranulocyte antibody and 67Ga scintigraphy in the evaluation of painful hip and knee prosthetic replacements

    International Nuclear Information System (INIS)

    Oliveira, S.; Pereira, L.; Joao, F.; Lima, J.

    2003-01-01

    Full text: Objective: To evaluate the utility of 99mTc-HMPAO labeled leucocyte, 99mTc-labeled anti-granulocyte antibody and 67Ga scintigraphy in patients suspected to have infected hip and knee replacements, from March/1998 to March/ 2002. Methods: Retrospective study of 33 patients (12 male, 21 female) with an average age of 61,1 ± 7,3 years. Nineteen had hip replacements and 14 were submitted to knee replacements. 99mTc-HMPAO labeled leucocyte scintigraphy was performed in 17 patients, 99mTc-labeled anti-granulocyte antibody scintigraphy in 13 patients and 67Ga scintigraphy in 3 patients. Twenty-six patients were also submitted to 3-phase 99mTc-MDP bone scintigraphy. Results were compared to those from studies with infection/inflammation agents. Concordant positive studies were considered to be a positive result for infection. A second study using 67Ga was also performed in 3 patients. Results: Diagnosis was based on surgical findings in 14 patients, pathologic study of biopsy specimen in 1 case and clinical/ imaging follow-up in 18 patients. Infection was detected in 22 cases and absent in 11. The conjoined evaluation of scintigraphic studies considered infection to be present in 20 cases and absent in 13. With infection/inflammation agents, 20 cases were positive (+) and 13 cases were negative (-). Using 99mTc-HMPAO labeled leucocytes, 12 cases were (+) and 5 cases were (-). With 99mTc-labeled anti-granulocyte antibodies, 8 cases were (+) and 5 were (-). With 67Ga, all 3 cases were (-). In patients with (+) studies using infection/ inflammation agents, a false positive case with 99mTc-HMPAO labeled leucocytes was reported. Two false negative cases were detected, both with 99mTc-labeled antigranulocyte antibodies, in patients with (-) studies. Regarding the studies with 99mTc-MDP, 24 were (+) and 2 were (-). Eighteen of these (+) cases were also (+) in studies with infection/inflammation agents, but 6 were (-) with these agents. Negative cases were also (-) in

  14. 21 CFR 872.3970 - Interarticular disc prosthesis (interpositional implant).

    Science.gov (United States)

    2010-04-01

    ... implant). 872.3970 Section 872.3970 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES DENTAL DEVICES Prosthetic Devices § 872.3970 Interarticular disc prosthesis (interpositional implant). (a) Identification. An interarticular disc prosthesis...

  15. Echocardiographic evaluation of heart valve prosthetic dysfunction

    Directory of Open Access Journals (Sweden)

    Yuriy Ivaniv

    2018-02-01

    Full Text Available Patients with replaced heart valve submitted to echocardiographic examination may have symptoms related either to valvular malfunction or ventricular dysfunction from different causes. Clinical examination is not reliable in a prosthetic valve evaluation and the main information regarding its function could be obtained using different cardiac ultrasound modalities. This review provides a description of echocardiographic and Doppler techniques useful in evaluation of prosthetic heart valves. For the interpretation of echocardiography there is a need in special knowledge of prosthesis types and possible reasons of prosthetic function deterioration. Echocardiography allows to reveal valve thrombosis, pannus formation, vegetation and such complications of infective endocarditis as valve ring abscess or dehiscence. Transthoracic echocardiography requires different section plane angles and unconventional views. Transesophageal echocardiography is more often used than in native valve examination due to better visualization of prosthetic valve structure and function. Three-dimensional echocardiography could provide more detailed visual information especially in the assessment of paravalvular regurgitation or valve obstruction.

  16. Prosthetic Mitral Valve Leaflet Escape

    Science.gov (United States)

    Kim, Darae; Hun, Sin Sang; Cho, In-Jeong; Shim, Chi-Young; Ha, Jong-Won; Chung, Namsik; Ju, Hyun Chul; Sohn, Jang Won

    2013-01-01

    Leaflet escape of prosthetic valve is rare but potentially life threatening. It is essential to make timely diagnosis in order to avoid mortality. Transesophageal echocardiography and cinefluoroscopy is usually diagnostic and the location of the missing leaflet can be identified by computed tomography (CT). Emergent surgical correction is mandatory. We report a case of fractured escape of Edward-Duromedics mitral valve 27 years after the surgery. The patient presented with symptoms of acute decompensated heart failure and cardiogenic shock. She was instantly intubated and mechanically ventilated. After prompt evaluation including transthoracic echocardiography and CT, the escape of the leaflet was confirmed. The patient underwent emergent surgery for replacement of the damaged prosthetic valves immediately. Eleven days after the surgery, the dislodged leaflet in iliac artery was removed safely and the patient recovered well. PMID:23837121

  17. Successful Management of Prosthetic Valve Brucella Endocarditis with Antibiotherapy Alone

    Directory of Open Access Journals (Sweden)

    José Pedro Fonseca

    2018-01-01

    Full Text Available Objectives: To report a case of mechanical aortic prosthesis Brucella endocarditis successfully treated with antibiotics alone. Materials and methods: We describe a clinical case and present a review of the literature. Results: A 60-year-old female farmer with a mechanical aortic prosthetic valve presented with low back pain and fever. She was diagnosed with prosthetic valve Brucella mellitensis endocarditis and was cured with antibiotic therapy alone. Few cases of successfully treated prosthetic valve Brucella endocarditis without surgery have been reported. Conclusion: Prosthetic valve Brucella endocarditis usually requires surgical valve replacement. However, selected patients may be successfully treated with antibiotic therapy alone.

  18. Responsiveness of the Prosthetic Esthetic Scale

    DEFF Research Database (Denmark)

    Øzhayat, Esben Boeskov

    2017-01-01

    Objectives The aim of the study was to evaluate the responsiveness of the Prosthetic Esthetic Index (PEI) in a population who received prosthetic replacements. Materials and methods Fifty-seven patients who received prosthetic replacement of at least one tooth by means of fixed or removable...... prosthesis were professionally esthetically evaluated using the PEI and the Dental Aesthetic Index (DAI) before and after treatment. The participants further evaluated their oral esthetics using the Oral Health Impact Profile Aesthetic (OHIP-Aes) and Orofacial Esthetic Index (OES). Responsiveness......-Aes and OES scores. The PEI was more consistent in responsiveness than the DAI. Conclusions The PEI shows sufficient responsiveness for use in longitudinal studies and for use as a follow-up measure in clinical practice. Clinical relevance The PEI can in a standardized manner monitor and document esthetic...

  19. LEUKOCYTE AND BACTERIA IMAGING IN PROSTHETIC JOINT INFECTION

    NARCIS (Netherlands)

    Glaudemans, Andor W. J. M.; Galli, Filippo; Pacilio, Marta; Signore, Alberto

    2013-01-01

    There has been a significant increase in the number of joint prosthesis replacements worldwide. Although relatively uncommon, complications can occur with the most serious being an infection. Various radiological and nuclear imaging techniques are available to diagnose prosthetic joint infections

  20. Prevention of Prosthetic Dentistry

    Directory of Open Access Journals (Sweden)

    Eremin O.V.

    2011-03-01

    Full Text Available Prevention in prosthetic dentistry is not just a regular oral hygiene and the prevention of caries in the early stages of its development. The initial goal of orthopedic and dental should be the ability to convey to the patient's sense of pros-thetics that proteziruya one saved more. An example is included prosthetic dental arch defects with bridges or single artificial crowns on implants that will prevent movement of teeth and the continuity of the dentition

  1. Prosthetic replacement for proximal humeral fractures.

    Science.gov (United States)

    Kontakis, George; Tosounidis, Theodoros; Galanakis, Ioannis; Megas, Panagiotis

    2008-12-01

    The ideal management of complex proximal humeral fractures continues to be debatable. Evolution of proximal humeral fracture management, during the past decade, led to the implementation of many innovations in surgical treatment. Even though the pendulum of treatment seems to swing towards new trends such as locked plating, hemiarthroplasty remains a valid and reliable option that serves the patient's needs well. Hemiarthroplasty is indicated for complex proximal humeral fractures in elderly patients with poor bone stock and when internal fixation is difficult or unreliable. Hemiarthroplasty provides a better result when it is performed early post-injury. Stem height, retroversion and tuberosity positioning are technical aspects of utmost importance. Additionally reverse total shoulder arthroplasty is an alternative new modality that can be used as a primary solution in selected patients with proximal humeral fracture treatment. Failed hemiarthroplasty and fracture sequelae can be successfully managed with reverse total shoulder arthroplasty. Individual decision-making and tailored treatment that takes into consideration the personality of the fracture and the patient's characteristics should be used.

  2. Radiological visualization of prosthetic heart valves in situ

    International Nuclear Information System (INIS)

    Hoffmeister, H.M.; Pirschel, J.

    1986-01-01

    To determine the radiographic appearance of prosthetic heart valves 15 different models were investigated in situ. Fluoroscopy with detail radiographs and standard chest-radiographs were used for identification of the specific type of the prosthesis, for determination of details of the valve apparatus and for evaluation of the motion of the valve disc/ball. - Fluoroscopy and routine radiographs provided sufficient information to identify all prosthetic heart valves with exception of the Xenomedica bioprosthesis. If radiopaque material was used for the valve disc/ball, fluoroscopic assessment of the function of the valve was possible. Thus, in most types of disc or ball valves the opening/closing of the valve can be visualized, whereas in bioprosthesis a radiological determination of the mechanical function is not possible. (orig.) [de

  3. LOW-MOLECULAR-WEIGHT HEPARIN TREATMENT FAILURE IN PREVENTION OF PROSTHETIC MITRAL VALVE THROMBOSIS

    OpenAIRE

    David Šuran; Vojko Kanič; Tatjana Golob Gulič; Husam Franjo Naji; Robert Lipovec

    2009-01-01

    Background Prosthetic heart valve thrombosis (PHVT) represents a dangerous postoperative complication following prosthetic heart valve replacement. Incidence varies according to different data from 0.5–4 % per year following mitral or aortic valve replacement in spite of adequate oral anticoagulation with coumarins. Case report We are presenting a case of prosthetic mitral valve thrombosis as a result of 6-month lowmolecular-weight heparin (LMWH) (nadroparine) treatment failure. Our pat...

  4. Factors Associated with Prosthetic Looseness in Lower Limb Amputees.

    Science.gov (United States)

    Phonghanyudh, Thong; Sutpasanon, Taweesak; Hathaiareerug, Chanasak; Devakula, M L Buddhibongsa; Kumnerddee, Wipoo

    2015-12-01

    To determine the factors associated with prosthetic looseness in lower limb amputees in Sisaket province. The present was a cross-sectional descriptive study. Subjects were lower limb amputees who previously obtained prostheses and required prosthetic replacements at the mobile prosthetic laboratory unit under the Prostheses Foundation of H.R.H. the Princess Mother at Khun Han Hospital, Sisaket province, in February 2013. Data including participant characteristics, prosthetic looseness data, and various variables were collected by direct semi-structured interview. Energy expenditures in physical activities were measured using the Thai version of the short format international physical activity questionnaire. Data between participants with and without prosthetic looseness were compared to determine prosthetic loosening associated factors. Among 101 participants enrolled, 33 (32.7%) had prosthetic looseness with average onset of 1.76 ± 1.67 years. Diabetes mellitus was the only significant factor associated with prosthetic looseness from both univariate and multivariate analyses (HR = 7.05, p = 0.002 and HR = 5.93, p = 0.007 respectively). Among the lower limb amputees in Sisaket province, diabetes mellitus was the only factor associated with prosthetic looseness. Therefore, diabetic screening should be supplemented in lower limb amputee assessment protocol. In addition, we recommend that amputees with diabetes mellitus should receive prosthesis check out at approximately

  5. The role of osteoblasts in peri-prosthetic osteolysis.

    LENUS (Irish Health Repository)

    O'Neill, S C

    2013-08-01

    Peri-prosthetic osteolysis and subsequent aseptic loosening is the most common reason for revising total hip replacements. Wear particles originating from the prosthetic components interact with multiple cell types in the peri-prosthetic region resulting in an inflammatory process that ultimately leads to peri-prosthetic bone loss. These cells include macrophages, osteoclasts, osteoblasts and fibroblasts. The majority of research in peri-prosthetic osteolysis has concentrated on the role played by osteoclasts and macrophages. The purpose of this review is to assess the role of the osteoblast in peri-prosthetic osteolysis. In peri-prosthetic osteolysis, wear particles may affect osteoblasts and contribute to the osteolytic process by two mechanisms. First, particles and metallic ions have been shown to inhibit the osteoblast in terms of its ability to secrete mineralised bone matrix, by reducing calcium deposition, alkaline phosphatase activity and its ability to proliferate. Secondly, particles and metallic ions have been shown to stimulate osteoblasts to produce pro inflammatory mediators in vitro. In vivo, these mediators have the potential to attract pro-inflammatory cells to the peri-prosthetic area and stimulate osteoclasts to absorb bone. Further research is needed to fully define the role of the osteoblast in peri-prosthetic osteolysis and to explore its potential role as a therapeutic target in this condition.

  6. Strut fracture and disc embolization of a Björk-Shiley mitral valve prosthesis: localization of embolized disc by computerized axial tomography.

    Science.gov (United States)

    Larrieu, A J; Puglia, E; Allen, P

    1982-08-01

    The case of a patient who survived strut fracture and embolization of a Björk-Shiley mitral prosthetic disc is presented. Prompt surgical treatment was directly responsible for survival. In addition, computerized axial tomography of the abdomen aided in localizing and retrieving the embolized disc, which was lodged at the origin of the superior mesenteric artery. A review of similar case reports from the literature supports our conclusions that the development of acute heart failure and absent or muffled prosthetic heart sounds in a patient with a Björk-Shiley prosthetic heart valve inserted prior to 1978 should raise the possibility of valve dysfunction and lead to early reoperation.

  7. GIANT PROSTHETIC VALVE THROMBUS

    Directory of Open Access Journals (Sweden)

    Prashanth Kumar

    2015-04-01

    Full Text Available Mechanical prosthetic valves are predisposed to bleeding, thrombosis & thromboembolic complications. Overall incidence of thromboembolic complications is 1% per year who are on oral anticoagulants, whereas bleeding complications incidence is 0.5% to 6.6% per year. 1, 2 Minimization of Scylla of thromboembolic & Charybdis of bleeding complication needs a balancing act of optimal antithrombotic therapy. We are reporting a case of middle aged male patient with prosthetic mitral valve presenting in heart failure. Patient had discontinued anticoagulants, as he had subdural hematoma in the past. He presented to our institute with a giant prosthetic valve thrombus.

  8. Rehabilitation and Prosthetic Services

    Science.gov (United States)

    ... Review Resources AT Education Blind Rehab Chiropractic Service Polytrauma/TBI Prosthetics & Sensory Aids Recreation Therapy More Health ... Military Sexual Trauma PTSD Research (MIRECC) Military Exposures Polytrauma Rehabilitation Spinal Cord Injury Telehealth Womens Health Issues ...

  9. Prosthetics / Limb Loss

    Science.gov (United States)

    ... implant to encourage the sealing process. Implanting titanium prosthetic components avoids the need for a socket. But preventing bacterial invasion and infection is a key challenge, one that this research ...

  10. Re-operation for aortic and mitral prosthetic dysfunctions.

    Science.gov (United States)

    Kaul, T K; Sastry, M R; Mercer, J L; Meade, J B

    1985-01-01

    The overall incidence of re-operation and prosthetic valve endocarditis was low in the present series as mechanical prostheses were used predominantly. The prosthetic dysfunctions were less frequent following the primary implantation with Bjork Shiley prostheses, but high operative risk was associated with the clotted Bjork Shiley prostheses. We also had unusual experience of strut fracture and sticking of Bjork Shiley discs in the closed position in both aortic and mitral positions. The early deaths were nil since the use of cardioplegic protection. Intra-operative bleeding due to adhesions can be minimised by using synthetic or heterologous pericardium during the primary operation.

  11. Prosthetic Joint Infections

    Science.gov (United States)

    Aslam, Saima; Darouiche, Rabih O.

    2012-01-01

    Prosthetic joint infections represent a major therapeutic challenge for both healthcare providers and patients. This paper reviews the predisposing factors, pathogenesis, microbiology, diagnosis, treatment and prophylaxis of prosthetic joint infection. The most optimal management strategy should be identified based on a number of considerations including type and duration of infection, antimicrobial susceptibility of the infecting pathogen, condition of infected tissues and bone stock, patient wishes and functional status. PMID:22847032

  12. Disc defect classification for optical disc drives

    NARCIS (Netherlands)

    Helvoirt, van J.; Leenknegt, G.A.L.; Steinbuch, M.; Goossens, H.J.

    2005-01-01

    Optical disc drives are subject to various disturbances and faults. A special type of fault is the so-called disc defect. In this paper we present an approach for disc defect classification. It is based on hierarchical clustering of measured signals that are affected by disc defects. The

  13. What is the superior surgical strategy for bi-level cervical spondylosis-anterior cervical disc replacement or anterior cervical decompression and fusion?: A meta-analysis from 11 studies.

    Science.gov (United States)

    Zhao, He; Duan, Li-Jun; Gao, Yu-Shan; Yang, Yong-Dong; Tang, Xiang-Sheng; Zhao, Ding-Yan; Xiong, Yang; Hu, Zhen-Guo; Li, Chuan-Hong; Yu, Xing

    2018-03-01

    Nowadays, anterior cervical artificial disc replacement (ACDR) has achieved favorable outcomes in treatment for patients with single-level cervical spondylosis. However, It is still controversial that whether or not it will become a potent therapeutic alternation in treating 2 contiguous levels cervical spondylosis compared with anterior cervical decompression and fusion (ACDF). Therefore, we conducted a systematic review and meta-analysis to compare the efficacy and safety of ACDR and ACDF in patients with 2 contiguous levels cervical spondylosis. According to the computer-based online search, PubMed, Embase, Web of Science, and Cochrane Library for articles published before July 1, 2017 were searched. The following outcome measures were extracted: neck disability index (NDI), visual analog scale (VAS) neck, VAS arm, Short Form (SF)-12 mental component summary (MCS), SF-12 physical component summary (PCS), overall clinical success (OCS), patient satisfaction (PS), device-related adverse event (DRAE), subsequent surgical intervention (SSI), neurological deterioration (ND), and adjacent segment degeneration (ASD). Methodological quality was evaluated independently by 2 reviewers using the Furlan for randomized controlled trial (RCT) and MINORS scale for clinical controlled trials (CCT). The chi-squared test and Higgin I test were used to evaluate the heterogeneity. A P bi-level cervical spondylosis, ACDR appears to provide superior clinical effectiveness and safety effects than ACDF. In the future, more high-quality RCTs are warranted to enhance this conclusion.

  14. Passive prosthetic hands and tools: A literature review.

    Science.gov (United States)

    Maat, Bartjan; Smit, Gerwin; Plettenburg, Dick; Breedveld, Paul

    2018-02-01

    The group of passive prostheses consists of prosthetic hands and prosthetic tools. These can either be static or adjustable. Limited research and development on passive prostheses has been performed although many people use these prosthesis types. Although some publications describe passive prostheses, no recent review of the peer-reviewed literature on passive prostheses is available. Review the peer-reviewed literature on passive prostheses for replacement of the hand. Literature review. Four electronic databases were searched using a Boolean combination of relevant keywords. English-language articles relevant to the objective were selected. In all, 38 papers were included in the review. Publications on passive prosthetic hands describe their users, usage, functionality, and problems in activities of daily living. Publications on prosthetic tools mostly focus on sport, recreation, and vehicle driving. Passive hand prostheses receive little attention in prosthetic research and literature. Yet one out of three people with a limb deficiency uses this type of prosthesis. Literature indicates that passive prostheses can be improved on pulling and grasping functions. In the literature, ambiguous names are used for different types of passive prostheses. This causes confusion. We present a new and clear classification of passive prostheses. Clinical relevance This review provides information on the users of passive prosthetic hands and tools, their usage and the functionality. Passive prostheses receive very little attention and low appreciation in literature. Passive prosthetic hands and tools show to be useful to many unilateral amputees and should receive more attention and higher acceptance.

  15. Description of the rates, trends and surgical burden associated with revision for prosthetic joint infection following primary and revision knee replacements in England and Wales: an analysis of the National Joint Registry for England, Wales, Northern Ireland and the Isle of Man.

    Science.gov (United States)

    Lenguerrand, Erik; Whitehouse, Michael R; Beswick, Andrew D; Toms, Andrew D; Porter, Martyn L; Blom, Ashley W

    2017-07-10

    To describe the prevalence rates of revision surgery for the treatment of prosthetic joint infection (PJI) for patients undergoing knee replacement, their time trends, the cumulative incidence function of revision for PJI and estimate the burden of PJI at health service level. We analysed revision knee replacements performed due to a diagnosis of PJI and the linked index procedures recorded in the National Joint Registry from 2003 to 2014 for England and Wales. The cohort analysed consisted of 679 010 index primary knee replacements, 33 920 index revision knee replacements and 8247 revision total knee replacements performed due to a diagnosis of PJI. The prevalence rates, their time trends investigated by time from index surgery to revision for PJI, cumulative incidence functions and the burden of PJI (total procedures) were calculated. Overall linear trends were investigated with log-linear regression. The incidence of revision total knee replacement due to PJI at 2 years was 3.2/1000 following primary and 14.4/1000 following revision knee replacement, respectively. The prevalence of revision due to PJI in the 3 months following primary knee replacement has risen by 2.5-fold (95% CI 1.2 to 5.3) from 2005 to 2013 and 7.5-fold (95% CI 1.0 to 56.1) following revision knee replacement. Over 1000 procedures per year are performed as a consequence of knee PJI, an increase of 2.8 from 2005 to 2013. Overall, 75% of revisions were two-stage with an increase in use of single-stage from 7.9% in 2005 to 18.8% in 2014. Although the risk of revision due to PJI following knee replacement is low, it is rising, and coupled with the established and further predicted increased incidence of both primary and revision knee replacements, this represents an increasing and substantial treatment burden for orthopaedic service delivery in England and Wales. This has implications for future service design and the funding of individual and specialist centres. © Article author

  16. Gonococcal Prosthetic Joint Infection.

    Science.gov (United States)

    Gassiep, Ian; Gilpin, Bradley; Douglas, Joel; Siebert, David

    2017-01-01

    Neisseria gonorrhoea is a common sexually transmitted infection worldwide. Disseminated gonococcal infection is an infrequent presentation and rarely can be associated with septic arthritis. Incidence of this infection is rising, both internationally and in older age groups. We present the first documented case of N. gonorrhoea prosthetic joint infection which was successfully treated with laparoscopic debridement and antimicrobial therapy.

  17. Amputation and Prosthetics

    Science.gov (United States)

    ... All Topics A-Z Videos Infographics Symptom Picker Anatomy Bones Joints Muscles Nerves Vessels Tendons About Hand Surgery What is a Hand Surgeon? What is a Hand Therapist? Media Find a Hand Surgeon Home Anatomy Amputation and Prosthetics Email to a friend * required ...

  18. Graft-Sparing Strategy for Thoracic Prosthetic Graft Infection.

    Science.gov (United States)

    Uchino, Gaku; Yoshida, Takeshi; Kakii, Bunpachi; Furui, Masato

    2018-04-01

     Thoracic prosthetic graft infection is a rare but serious complication with no standard management. We reported our surgical experience on graft-sparing strategy for thoracic prosthetic graft infection.  This study included patients who underwent graft-sparing surgery for thoracic prosthetic graft infection at Matsubara Tokushukai Hospital in Japan from January 2000 to October 2017.  There were 17 patients included in the analyses, with a mean age at surgery of 71.0 ± 10.5 years; 11 were men. In-hospital mortality was observed in five patients (29.4%).  Graft-sparing surgery for thoracic prosthetic graft infection is an alternative option particularly for early graft infection after hemiarch replacement. Georg Thieme Verlag KG Stuttgart · New York.

  19. The radiology of prosthetic heart valves

    International Nuclear Information System (INIS)

    Steiner, R.M.; Flicker, S.

    1985-01-01

    The development of prosthetic heart valves in the late 1950s ushered in a new era in the treatment of heart disease. The radiologist has an important role to play preoperatively in the diagnosis of valvular heart disease. Radiology is valuable in identification of the implanted prosthetic valve and recognition of complications associated with valve implantation. Radiologists must be familiar with the imaging techniques best suited to evaluate the function of the valve prosthesis in question. In this chapter the authors discuss the radiographic approach to the evaluation of the status of patients for valve replacement and the imaging problems peculiar to the types of valves in current use. The relative value of plain-film radiography, fluoroscopy, videorecording and cinerecording, and aortography is addressed, as well as the potential value of magnetic resonance imaging and subsecond dynamic computed tomography

  20. Welding of Prosthetic Alloys

    Directory of Open Access Journals (Sweden)

    Wojciechowska M.

    2015-04-01

    Full Text Available This paper presents the techniques of joining metal denture elements, used in prosthetic dentistry: the traditional soldering technique with a gas burner and a new technique of welding with a laser beam; the aim of the study was to make a comparative assessment of the quality of the joints in view of the possibility of applying them in prosthetic structures. Fractographic examinations were conducted along with tensile strength and impact strength tests, and the quality of the joints was assessed compared to the solid metal. The experiments have shown that the metal elements used to make dentures, joined by the technique which employs a laser beam, have better strength properties than those achieved with a gas burner.

  1. Immediate natural tooth pontic: A viable yet temporary prosthetic solution: A patient reported outcome

    Directory of Open Access Journals (Sweden)

    Sudhir Bhandari

    2012-01-01

    Conclusion: The concept of immediate pontic placement is surely a viable treatment option and promises an excellent transient esthetic solution for a lost tooth as well as enables good preparation of the extraction site for future prosthetic replacement.

  2. Rotationplasty with vascular reconstruction for prosthetic knee joint infection.

    Science.gov (United States)

    Fujiki, Masahide; Miyamoto, Shimpei; Nakatani, Fumihiko; Kawai, Akira; Sakuraba, Minoru

    2015-01-01

    Rotationplasty is used most often as a function-preserving salvage procedure after resection of sarcomas of the lower extremity; however, it is also used after infection of prosthetic knee joints. Conventional vascular management during rotationplasty is to preserve and coil major vessels, but recently, transection and reanastomosis of the major vessels has been widely performed. However, there has been little discussion regarding the optimal vascular management of rotationplasty after infection of prosthetic knee joints because rotationplasty is rarely performed for this indication. We reviewed four patients who had undergone resection of osteosarcomas of the femur, placement of a prosthetic knee joint, and rotationplasty with vascular reconstruction from 2010 to 2013. The mean interval between prosthetic joint replacement and rotationplasty was 10.4 years and the mean interval between the diagnosis of prosthesis infection and rotationplasty was 7.9 years. Rotationplasty was successful in all patients; however, in one patient, arterial thrombosis developed and necessitated urgent surgical removal and arterial reconstruction. All patients were able to walk independently with a prosthetic limb after rehabilitation. Although there is no consensus regarding the most appropriate method of vascular management during rotationplasty for revision of infected prosthetic joints, vascular transection and reanastomosis is a useful option.

  3. Role of CT in patients with prosthetic heart valves

    NARCIS (Netherlands)

    Suchá, D.

    2016-01-01

    Valvular heart disease accounts for a substantial part of the cardiovascular disease worldwide with an estimated prevalence of 2.5% in the Western population aged <65 years and over 13% in the population aged >75 years. Surgical prosthetic heart valve (PHV) replacement is the indicated therapy for

  4. Disc degeneration: current surgical options

    Directory of Open Access Journals (Sweden)

    C Schizas

    2010-10-01

    Full Text Available Chronic low back pain attributed to lumbar disc degeneration poses a serious challenge to physicians. Surgery may be indicated in selected cases following failure of appropriate conservative treatment. For decades, the only surgical option has been spinal fusion, but its results have been inconsistent. Some prospective trials show superiority over usual conservative measures while others fail to demonstrate its advantages. In an effort to improve results of fusion and to decrease the incidence of adjacent segment degeneration, total disc replacement techniques have been introduced and studied extensively. Short-term results have shown superiority over some fusion techniques. Mid-term results however tend to show that this approach yields results equivalent to those of spinal fusion. Nucleus replacement has gained some popularity initially, but evidence on its efficacy is scarce. Dynamic stabilisation, a technique involving less rigid implants than in spinal fusion and performed without the need for bone grafting, represents another surgical option. Evidence again is lacking on its superiority over other surgical strategies and conservative measures. Insertion of interspinous devices posteriorly, aiming at redistributing loads and relieving pain, has been used as an adjunct to disc removal surgery for disc herniation. To date however, there is no clear evidence on their efficacy. Minimally invasive intradiscal thermocoagulation techniques have also been tried, but evidence of their effectiveness is questioned. Surgery using novel biological solutions may be the future of discogenic pain treatment. Collaboration between clinicians and basic scientists in this multidisciplinary field will undoubtedly shape the future of treating symptomatic disc degeneration.

  5. An Evaluation of Dental Prosthetic Status and Prosthetic Needs ...

    African Journals Online (AJOL)

    present cross‑sectional study aimed to evaluate the dental prosthetic status and prosthetic needs among eunuchs .... who consented to become part of the study guided us to the .... to the reason that our study population comprised of adults with low SES. ... Arora M, Schwarz E, Sivaneswaran S, Banks E. Cigarette smoking.

  6. Second-site prosthetic joint infection in patients with multiple prosthetic joints.

    Science.gov (United States)

    Clesham, Kevin; Hughes, Andrew J; O' hEireamhoin, Sven; Fleming, Catherine; Murphy, Colin G

    2018-04-10

    Prosthetic joint infections (PJIs) are among the most serious complications in arthroplasty. A second-site PJI in patients with multiple prosthetic joints increases morbidity, with many requiring further revision procedures. We aimed to establish why some patients with multiple joints develop second-site infections. Our institution's arthroplasty database was reviewed from 2004 to 2017. All PJIs were identified, and all patients with more than one prosthetic joint in situ were included. We recorded risk factors, causative organisms, number of procedures and length of stay. Forty-four patients meeting the criteria were identified. Four patients (9.1%) developed second-site infection. Eight patients (18.2%) developed re-infection of the primary PJI. Positive MRSA carrier status and PJI of a total knee replacement were associated with an increased risk of a second episode of infection. Patients who developed further infection had more frequent admission and longer lengths of stay than isolated PJIs. Higher morbidity and use of hospital resources are associated with this cohort of patients. PJIs in total knee replacements and positive MRSA status are associated with higher rates of second infection. Identifying this vulnerable cohort of patients at an early stage is critical to ensure measures are taken to reduce the risks of further infection.

  7. Prosthetic Joint Infection

    Science.gov (United States)

    Tande, Aaron J.

    2014-01-01

    SUMMARY Prosthetic joint infection (PJI) is a tremendous burden for individual patients as well as the global health care industry. While a small minority of joint arthroplasties will become infected, appropriate recognition and management are critical to preserve or restore adequate function and prevent excess morbidity. In this review, we describe the reported risk factors for and clinical manifestations of PJI. We discuss the pathogenesis of PJI and the numerous microorganisms that can cause this devastating infection. The recently proposed consensus definitions of PJI and approaches to accurate diagnosis are reviewed in detail. An overview of the treatment and prevention of this challenging condition is provided. PMID:24696437

  8. Cost analysis of debridement and retention for management of prosthetic joint infection.

    Science.gov (United States)

    Peel, T N; Dowsey, M M; Buising, K L; Liew, D; Choong, P F M

    2013-02-01

    Prosthetic joint infection remains one of the most devastating complications of arthroplasty. Debridement and retention of the prosthesis is an attractive management option in carefully selected patients. Despite this, there are no data investigating the cost of this management modality for prosthetic joint infections. The aim of this case-control study was to calculate the cost associated with debridement and retention for management of prosthetic joint infection compared with primary joint replacement surgery without prosthetic joint infection. From 1 January 2008 to 30 June 2010, there were 21 prosthetic joint infections matched to 42 control patients. Controls were matched to cases according to the arthroplasty site, age and sex. Cases had a greater number of unplanned readmissions (100% vs. 7.1%; p prosthetic joint infection the total cost, including index operation and costs of management of the prosthetic joint infection, was 3.1 times the cost of primary arthoplasty; the mean cost for cases was Australian dollars (AUD) $69,414 (±29,869) compared with $22,085 (±8147) (p prosthetic joint infections will also increase, placing significant burden on the health system. Our study adds significantly to the growing body of evidence highlighting the substantial costs associated with prosthetic joint infection. © 2011 The Authors. Clinical Microbiology and Infection © 2011 European Society of Clinical Microbiology and Infectious Diseases.

  9. Cervical artificial disc extrusion after a paragliding accident

    OpenAIRE

    Niu, Tianyi; Hoffman, Haydn; Lu, Daniel C.

    2017-01-01

    Background: Cervical total disc replacement (TDR) is an established alternative to anterior cervical discectomy and fusion (ACDF) with excellent long-term outcomes and low failure rates. Cases of implant failure and migration are scarce and primarily limited to several years postoperatively. The authors report a case of anterior extrusion of a C4-C5 ProDisc-C (DePuy Synthes, West Chester, PA, USA) cervical artificial disc (CAD) 14 months after placement due to minor trauma. Case Description: ...

  10. Valve assembly having remotely replaceable bearings

    International Nuclear Information System (INIS)

    Johnson, E.R.; Tanner, D.E.

    1980-01-01

    A valve assembly having remotely replaceable bearings is disclosed wherein a valve disc is supported within a flow duct for rotation about a pair of axially aligned bearings, one of which is carried by a spindle received within a diametral bore in the valve disc, and the other of which is carried by a bearing support block releasably mounted on the duct circumferentially of an annular collar on the valve disc coaxial with its diametrical bore. The spindle and bearing support block are adapted for remote removal to facilitate servicing or replacement of the valve disc support bearings

  11. Radially truncated galactic discs

    NARCIS (Netherlands)

    Grijs, R. de; Kregel, M.; Wesson, K H

    2000-01-01

    Abstract: We present the first results of a systematic analysis of radially truncatedexponential discs for four galaxies of a sample of disc-dominated edge-onspiral galaxies. Edge-on galaxies are very useful for the study of truncatedgalactic discs, since we can follow their light distributions out

  12. Björk-Shiley strut fracture and disc escape: literature review and a method of disc retrieval.

    Science.gov (United States)

    Hendel, P N

    1989-03-01

    Embolization of a prosthetic valve poppet is a rare but life-threatening event. It was reported sporadically before the introduction of the Björk-Shiley 70-degree convexoconcave prosthesis in 1980. Since that time, there have been a large number of reported mechanical failures with disc escape. The rate for the 29-mm to 33-mm mitral valves is estimated as 5.2%. In 29 of 35 patients (including the 2 presented here) in whom the site of disc lodgment could be determined, the disc was in the descending or abdominal aorta. Fifteen of these patients died. Six survivors had the disc removed at the same operation and 6 at a later operation. In 2 patients, the disc was not removed. In 2 patients in whom the disc was not removed initially, it was thought to contribute to postoperative complications. Two more cases of structural failure of the Björk-Shiley convexoconcave prosthesis are presented. A transpericardial approach to the descending aorta on bypass is described. It allows easy removal of the disc and eliminates the need for a second operation.

  13. Management of Prosthetic Joint Infection.

    Science.gov (United States)

    Tande, Aaron J; Gomez-Urena, Eric O; Berbari, Elie F; Osmon, Douglas R

    2017-06-01

    Although uncommon, prosthetic joint infection is a devastating complication. This challenging condition requires a coordinated management approach to achieve good patient outcomes. This review details the general principles to consider when managing patients with prosthetic joint infection. The different medical/surgical treatment strategies and how to appropriately select a strategy are discussed. The data to support each strategy are presented, along with discussion of antimicrobial strategies in specific situations. Copyright © 2017 Elsevier Inc. All rights reserved.

  14. Advanced Prosthetic Gait Training Tool

    Science.gov (United States)

    2015-12-01

    modules to train individuals to distinguish gait deviations (trunk motion and lower-limb motion). Each of these modules help trainers improve their...AWARD NUMBER: W81XWH-10-1-0870 TITLE: Advanced Prosthetic Gait Training Tool PRINCIPAL INVESTIGATOR: Dr. Karim Abdel-Malek CONTRACTING...study is to produce a computer-based Advanced Prosthetic Gait Training Tool to aid in the training of clinicians at military treatment facilities

  15. Which prosthetic foot to prescribe?

    OpenAIRE

    De Asha, AR; Barnett, CT; Struchkov, V; Buckley, JG

    2017-01-01

    Introduction: \\ud Clinicians typically use findings from cohort studies to objectively inform judgements regarding the potential (dis)advantages of prescribing a new prosthetic device. However, before finalising prescription a clinician will typically ask a patient to 'try out' a change of prosthetic device while the patient is at the clinic. Observed differences in gait when using the new device should be the result of the device’s mechanical function, but could also conceivably be due to pa...

  16. Pre-prosthetic surgery: Mandible

    Directory of Open Access Journals (Sweden)

    Veeramalai Naidu Devaki

    2012-01-01

    Full Text Available Pre-prosthetic surgery is that part of oral and maxillofacial surgery which restores oral function and facial form. This is concerned with surgical modification of the alveolar process and its surrounding structures to enable the fabrication of a well-fitting, comfortable, and esthetic dental prosthesis. The ultimate goal of pre-prosthetic surgery is to prepare a mouth to receive a dental prosthesis by redesigning and smoothening bony edges.

  17. Red flag in the emergency department: fracture and primary failure of a prosthetic valve.

    Science.gov (United States)

    Ozsarac, Murat; Karcioglu, Ozgur; Ayrik, Cuneyt; Bozkurt, Seyran; Turkcuer, Ibrahim; Gumrukcu, Serhat

    2005-07-01

    This case report concerns a patient with fracture and primary dysfunction of a prosthetic valve. A 40-year-old man presented to the Emergency Department with a chief complaint of breakthrough pleuritic back pain and shortness of breath. Past surgical history was significant only for an aortic valve replacement and mitral valve replacement performed 16 years prior. The transthoracic echocardiography raised suspicion of prosthesis malposition. The patient was taken to the operating room by cardiothoracic surgeons for valve replacement. Operative findings revealed that a prosthetic valve leaflet in the mitral position had broken off. Primary prosthetic valve failure should not be overlooked in the differential diagnosis of patients with valve replacement and a rapidly deteriorating clinical course. Emergency echocardiography is a guide to convenient diagnosis and management. Early surgical consultation and early reparative surgery might prevent unnecessary morbidity and mortality.

  18. Extrinsic mechanism obstructing the opening of a prosthetic mitral valve: an unusual case of suture entrapment.

    Science.gov (United States)

    Ozkan, Mehmet; Astarcioglu, Mehmet Ali; Karakoyun, Suleyman; Balkanay, Mehmet

    2012-02-01

    Obstruction to a prosthetic cardiac valve is a well-recognized complication of cardiac valve replacement. Malfunction of the mobile component of a prosthetic valve to open or close correctly may occur in consequence of intrinsic or extrinsic causes (thrombus, vegetation, entrapment of left ventricular myocardium, suture entanglement, and pannus formation) that may result prosthetic valve stenosis and/or insufficiency. In the case we report a 48-year-old female with valve dysfunction occurred early after surgery, as one valve leaflet was only able to partially open due to suture entrapment. © 2011, Wiley Periodicals, Inc.

  19. Combined computed tomography and fluorodeoxyglucose positron emission tomography in the diagnosis of prosthetic valve endocarditis: a case series.

    Science.gov (United States)

    Bartoletti, Michele; Tumietto, Fabio; Fasulo, Giovanni; Giannella, Maddalena; Cristini, Francesco; Bonfiglioli, Rachele; Raumer, Luigi; Nanni, Cristina; Sanfilippo, Silvia; Di Eusanio, Marco; Scotton, Pier Giorgio; Graziosi, Maddalena; Rapezzi, Claudio; Fanti, Stefano; Viale, Pierluigi

    2014-01-13

    The diagnosis of prosthetic valve endocarditis is challenging. The gold standard for prosthetic valve endocarditis diagnosis is trans-esophageal echocardiography. However, trans-esophageal echocardiography may result in negative findings or yield images difficult to differentiate from thrombus in patients with prosthetic valve endocarditis. Combined computed tomography and fluorodeoxyglucose positron emission tomography is a potentially promising diagnostic tool for several infectious conditions and it has also been employed in patients with prosthetic valve endocarditis but data are still scant. We reviewed the charts of 6 patients with prosthetic aortic valves evaluated for suspicion of prosthetic valve endocarditis, at two different hospital, over a 3-year period. We found 3 patients with early-onset PVE cases and blood cultures yielding Pseudomonas aeruginosa, Staphylococcus epidermidis and Staphylococcus lugdunensis, respectively; and 3 late-onset cases in the remaining 3 patients with isolation in the blood of Streptococcus bovis, Candida albicans and P. aeruginosa, respectively. Initial trans-esophageal echocardiography was negative in all the patients, while fluorodeoxyglucose positron emission tomography showed images suspicious for prosthetic valve endocarditis. In 4 out of 6 patients valve replacement was done with histology confirming the prosthetic valve endocarditis diagnosis. After an adequate course of antibiotic therapy fluorodeoxyglucose positron emission tomography showed resolution of prosthetic valve endocarditis in all the patients. Our experience confirms the potential role of fluoroseoxyglucose positron emission tomography in the diagnosis and follow-up of prosthetic valve endocarditis.

  20. Can we close large prosthetic space with orthodontics?

    Science.gov (United States)

    Mesko, Mauro Elias; Skupien, Jovito Adiel; Valentini, Fernanda; Pereira-Cenci, Tatiana

    2013-01-01

    For years, the treatment for the replacement of a missing tooth was a fixed dental prosthesis. Currently, implants are indicated to replace missing teeth due to high clinical success and with the advantage of not performing preparations in the adjacent tooth. Another option for space closure is the use of orthodontics associated to miniscrews for anchorage allowing better control of the orthodontic biomechanics and especially making possible closure of larger prosthetic spaces. Thus, this article describes two cases with indications and discussion of the advantages and disadvantages of using orthodontics for prosthetic spaces closure. The cases herein presented show that it is possible to close an space when there are available teeth in the adjacent area. It can be concluded that when a malocclusion is present there will be a strong trend to indicate space closure by orthodontic movement as it preserves natural teeth and seems a more physiological approach.

  1. Mechanical design criteria for intervertebral disc tissue engineering.

    Science.gov (United States)

    Nerurkar, Nandan L; Elliott, Dawn M; Mauck, Robert L

    2010-04-19

    Due to the inability of current clinical practices to restore function to degenerated intervertebral discs, the arena of disc tissue engineering has received substantial attention in recent years. Despite tremendous growth and progress in this field, translation to clinical implementation has been hindered by a lack of well-defined functional benchmarks. Because successful replacement of the disc is contingent upon replication of some or all of its complex mechanical behaviors, it is critically important that disc mechanics be well characterized in order to establish discrete functional goals for tissue engineering. In this review, the key functional signatures of the intervertebral disc are discussed and used to propose a series of native tissue benchmarks to guide the development of engineered replacement tissues. These benchmarks include measures of mechanical function under tensile, compressive, and shear deformations for the disc and its substructures. In some cases, important functional measures are identified that have yet to be measured in the native tissue. Ultimately, native tissue benchmark values are compared to measurements that have been made on engineered disc tissues, identifying where functional equivalence was achieved, and where there remain opportunities for advancement. Several excellent reviews exist regarding disc composition and structure, as well as recent tissue engineering strategies; therefore this review will remain focused on the functional aspects of disc tissue engineering. Copyright 2009 Elsevier Ltd. All rights reserved.

  2. Floppy disc units for data collection from neutron beam experiments

    International Nuclear Information System (INIS)

    Hall, J.W.

    1976-02-01

    The replacement of paper tape output facilities on neutron beam equipment on DIDO and PLUTO reactors by floppy discs will improve reliability and provide a more manageable data storage medium. The cost of floppy disc drives is about the same as a tape punch and printer and less than other devices such as a magnetic tape. Suitable floppy disc controllers are not at present available and a unit was designed as a directly pluggable replacement for paper tape punches. This design was taken as the basis in the development of a prototype unit for use in neutron beam equipment. The circuit operation for this prototype unit is described. (author)

  3. The Prosthetic Workflow in the Digital Era

    Directory of Open Access Journals (Sweden)

    Lidia Tordiglione

    2016-01-01

    Full Text Available The purpose of this retrospective study was to clinically evaluate the benefits of adopting a full digital workflow for the implementation of fixed prosthetic restorations on natural teeth. To evaluate the effectiveness of these protocols, treatment plans were drawn up for 15 patients requiring rehabilitation of one or more natural teeth. All the dental impressions were taken using a Planmeca PlanScan® (Planmeca OY, Helsinki, Finland intraoral scanner, which provided digital casts on which the restorations were digitally designed using Exocad® (Exocad GmbH, Germany, 2010 software and fabricated by CAM processing on 5-axis milling machines. A total of 28 single crowns were made from monolithic zirconia, 12 vestibular veneers from lithium disilicate, and 4 three-quarter vestibular veneers with palatal extension. While the restorations were applied, the authors could clinically appreciate the excellent match between the digitally produced prosthetic design and the cemented prostheses, which never required any occlusal or proximal adjustment. Out of all the restorations applied, only one exhibited premature failure and was replaced with no other complications or need for further scanning. From the clinical experience gained using a full digital workflow, the authors can confirm that these work processes enable the fabrication of clinically reliable restorations, with all the benefits that digital methods bring to the dentist, the dental laboratory, and the patient.

  4. Superluminous accretion discs

    Energy Technology Data Exchange (ETDEWEB)

    Sikora, M [Cambridge Univ. (UK). Inst. of Astronomy; Polska Akademia Nauk, Warsaw. Centrum Astronomiczne)

    1981-07-01

    Upper limits are computed for the total luminosities and collimation of radiation from thick, radiation supported accretion discs around black holes. Numerical results are obtained for the 'extreme' discs with rsub(out) = 10/sup 3/ GMsub(BH)/c/sup 2/, the angular momentum of the black hole being Jsub(BH) = 0.998 GMsub(BH)/c. The high luminosity (L approximately 8.5 Lsub(Edd)) and substantial collimation of radiation found for these discs indicate that such discs can explain both the high luminosities of quasars and similar objects and may produce some of the observed beams and jets.

  5. Prosthetic valve endocarditis caused by Staphylococcus capitis: report of 4 cases

    Directory of Open Access Journals (Sweden)

    Wada Yuko

    2011-10-01

    Full Text Available Abstract Although Staphylococcus capitis is considered to be a rare causative organism for prosthetic valve endocarditis, we report 4 such cases that were encountered at our hospital over the past 2 years. Case 1 was a 79-year-old woman who underwent aortic valve replacement with a bioprosthetic valve and presented with fever 24 days later. Transesophageal echocardiography revealed an annular abscess in the aorto-mitral continuity and mild perivalvular regurgitation. We performed emergency surgery 5 days after the diagnosis of prosthetic valve endocarditis was made. Case 2 was a 79-year-old woman presenting with fever 40 days after aortic valve replacement with a bioprosthesis. Transesophageal echocardiography showed vegetation on the valve, and she underwent urgent surgery 2 days after prosthetic valve endocarditis was diagnosed. In case 3, a 76-year-old man presented with fever 53 days after aortic valve replacement with a bioprosthesis. Vegetation on the prosthetic leaflet could be seen by transesophageal echocardiography. He underwent emergency surgery 2 days after the diagnosis of prosthetic valve endocarditis was made. Case 4 was a 68-year-old woman who collapsed at her home 106 days after aortic and mitral valve replacement with bioprosthetic valves. Percutaneous cardiopulmonary support was started immediately after massive mitral regurgitation due to prosthetic valve detachment was revealed by transesophageal echocardiography. She was transferred to our hospital by helicopter and received surgery immediately on arrival. In all cases, we re-implanted another bioprosthesis after removal of the infected valve and annular debridement. All patients recovered without severe complications after 2 months of antibiotic treatment, and none experienced re-infection during 163 to 630 days of observation. Since the time interval between diagnosis of prosthetic valve endocarditis and valve re-replacement ranged from 0 to 5 days, early surgical removal

  6. [Intra-prosthetic dislocation of the Bousquet dual mobility socket].

    Science.gov (United States)

    Lecuire, F; Benareau, I; Rubini, J; Basso, M

    2004-05-01

    The Bousquet system is a dual mobility head-polyethylene polyethylene-metal cup socket. The polyethylene insert retaining the femoral head moves in the noncemented metal cup, increasing both mobility and stability. Between 1989 and 1997, seven cases of intra-prosthetic dislocation (six patients) were observed. The femoral head escaped from the polyethylene insert due to wear. On the average, this complication occurred ten Years after implantation. Risk of dislocation was high in six of the seven hips. All patients had a large sized stem screwed into the femoral neck. There was a characteristic radiological aspect with loss of the concentric head metal cup configuration. The head was applied against the upper wall of the metal cup. Surgical replacement was undertaken early in six patients by simply changing the insert without modifying the other stable components. Outcome remained good at three to eight Years. One patient underwent late surgery. The insert and the cup were replaced with a classical implant. Functional outcome was good but recurrent dislocation occurred. At mid-term, intra-prosthetic dislocation of dual mobility sockets appears to be exceptional. Dislocation results from polyethylene wear leading to failure of the insert to retain the prosthetic head. Wear is favored by direct phenomena (direct contact between neck and insert which can occur early if there is a small difference in the head and neck diameters) or indirect phenomena (factors limiting polyethylene metal-cup mobility). Surgical treatment is necessary. If undertaken early, replacement with a modular head and insert can be sufficient if the prosthesis has not loosened but the metal cup may have to be replaced in the event of metal-metal contact between the head and the cup. Prosthesis loosening, wear of the metal cup, or an identified cause of dislocation imply replacing the failing implants. Implantation of the dual mobility system is particularly interesting for patients with a high risk

  7. Prosthetic joint infection caused by Trueperella bernardiae.

    Science.gov (United States)

    Gilarranz, Raul; Chamizo, Francisco; Horcajada, Iballa; Bordes-Benítez, Ana

    2016-09-01

    Trueperella bernardiae is a Gram-positive coryneform bacilli which role as human pathogen is unknown because it has been usually considered a contaminant. Furthermore its identification by biochemical test was difficult. We describe a prosthetic joint infection in a women who years ago underwent a total knee replacement with superinfection and necrosis of the patellar tendon as major complications. In the sample of synovial fluid collected grew a gram-positive bacilli which was identified by matrix-assisted laser desorption/ionization time-of-flight (MALDI-TOF) as T. bernardiae. The patient was treated with ciprofloxacin and currently preserves the prosthesis without signs of infection. Copyright © 2016 Japanese Society of Chemotherapy and The Japanese Association for Infectious Diseases. Published by Elsevier Ltd. All rights reserved.

  8. Instability of warped discs

    Science.gov (United States)

    Doǧan, S.; Nixon, C. J.; King, A. R.; Pringle, J. E.

    2018-05-01

    Accretion discs are generally warped. If a warp in a disc is too large, the disc can `break' apart into two or more distinct planes, with only tenuous connections between them. Further, if an initially planar disc is subject to a strong differential precession, then it can be torn apart into discrete annuli that precess effectively independently. In previous investigations, torque-balance formulae have been used to predict where and when the disc breaks into distinct parts. In this work, focusing on discs with Keplerian rotation and where the shearing motions driving the radial communication of the warp are damped locally by turbulence (the `diffusive' regime), we investigate the stability of warped discs to determine the precise criterion for an isolated warped disc to break. We find and solve the dispersion relation, which, in general, yields three roots. We provide a comprehensive analysis of this viscous-warp instability and the emergent growth rates and their dependence on disc parameters. The physics of the instability can be understood as a combination of (1) a term that would generally encapsulate the classical Lightman-Eardley instability in planar discs (given by ∂(νΣ)/∂Σ < 0) but is here modified by the warp to include ∂(ν1|ψ|)/∂|ψ| < 0, and (2) a similar condition acting on the diffusion of the warp amplitude given in simplified form by ∂(ν2|ψ|)/∂|ψ| < 0. We discuss our findings in the context of discs with an imposed precession, and comment on the implications for different astrophysical systems.

  9. 21 CFR 870.3710 - Pacemaker repair or replacement material.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Pacemaker repair or replacement material. 870.3710... (CONTINUED) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Prosthetic Devices § 870.3710 Pacemaker repair or replacement material. (a) Identification. A pacemaker repair or replacement material is an...

  10. Candida infection of a prosthetic shoulder joint

    Energy Technology Data Exchange (ETDEWEB)

    Lichtman, E.A.

    1983-09-01

    A heroin addict developed a Candida parapsilosis infection in a prosthetic shoulder joint. Radiographs showed loose fragments of cement with prosthetic loosening. The patient was treated with removal of the prosthesis and intravenous amphotericin B followed by oral ketoconazole.

  11. Candida infection of a prosthetic shoulder joint

    International Nuclear Information System (INIS)

    Lichtman, E.A.; Veterans Administration Medical Center, New York

    1983-01-01

    A heroin addict developed a Candida parapsilosis infection in a prosthetic shoulder joint. Radiographs showed loose fragments of cement with prosthetic loosening. The patient was treated with removal of the prosthesis and intravenous amphotericin B followed by oral ketoconazole. (orig.)

  12. Disc operational system

    International Nuclear Information System (INIS)

    Veretenov, V.Yu.; Volkov, A.I.; Gurevich, M.I.; Kozik, V.S.; Pod'yachev, E.I.; Shapiro, M.L.

    1974-01-01

    A disc operational system is proposed, which is based on the file structure and designed for use in a BESM-6 computer with the software system comprising a dispatcher DD-73 and a monitor 'Dubna'. The main distinguishing feature of the disc operational system is the decentralization of the file system. Each disc package is an independent file unaffected by the state of the other disc packages. The use of several disc packages is allowed. The above feature of the disc operational system makes it possible to simplify the language of communication with the system, to give the user the opportunity of controlling the file quite independently, and to simplify the maintenance of the discs by the computer personnel. One and the same disc can be simultaneously addressed by all problems in the processor (both mathematical and service). A single file, however, may be used in the recording mode by only one problem. The description presented is the instruction for users. It also describes special possibilities open to the system programmers [ru

  13. Intratracheal Seal Disc

    DEFF Research Database (Denmark)

    Christiansen, Karen J; Moeslund, Niels; Lauridsen, Henrik

    2017-01-01

    . The device consisted of an intratracheal silicone seal disc fixated by a cord through the stoma to an external part. At day 14, computed tomography (CT) was performed before the device was extracted. With the pulling of a cord, the disc unraveled into a thin thread and was extracted through the stoma. At day...

  14. Double rupture disc experience

    International Nuclear Information System (INIS)

    1979-01-01

    Result of these observations, comparisons and evaluations can be summarized in the following list of concerns regarding the use of double rupture discs coupled to the liquid space of a steam generator that is subjected to a large leak sodium water reaction event. Single rupture disc show delayed collapse characteristics in LLTR Series I and double disc assemblies are presumed to be more complex with additional delay before opening to give pressure relief. Delayed failure increases pressures in the IHTS and must be adequately covered by design requirements. With CRBR design, the first disc may fail only partially reducing the loading on the second disc with the result that relief performance may not meet requirements

  15. M6-C artificial disc placement.

    Science.gov (United States)

    Coric, Domagoj; Parish, John; Boltes, Margaret O

    2017-01-01

    There has been a steady evolution of cervical total disc replacement (TDR) devices over the last decade resulting in surgical technique that closely mimics anterior cervical discectomy and fusion as well as disc design that emphasizes quality of motion. The M6-C TDR device is a modern-generation artificial disc composed of titanium endplates with tri-keel fixation as well as a polyethylene weave with a polyurethane core. Although not yet approved by the FDA, M6-C has finished a pilot and pivotal US Investigational Device Exemption (IDE) study. The authors present the surgical technique for implantation of a 2-level M6-C cervical TDR device. The video can be found here: https://youtu.be/rFEAqINLRCo .

  16. A rare case of prosthetic endocarditis and dehiscence in a mechanical valved conduit.

    Science.gov (United States)

    Kannan, Arun; Smith, Cristy; Subramanian, Sreekumar; Janardhanan, Rajesh

    2014-02-07

    A middle-aged adult patient with a history of aortic root replacement with a mechanical valved conduit and remote chest trauma was referred to our institution with prosthetic endocarditis. Transoesophageal echocardiogram at our institution confirmed a near-complete dehiscence of the prosthetic aortic valve from the conduit, with significant perivalvular flow forming a pseudoaneurysm. The patient underwent a high-risk re-operation, involving redo aortic root replacement with a homograft after extensive debridement of the infected tissue. The patient was discharged to an outside facility after an uncomplicated hospital course, and remains stable.

  17. Control method for prosthetic devices

    Science.gov (United States)

    Bozeman, Richard J., Jr. (Inventor)

    1995-01-01

    A control system and method for prosthetic devices is provided. The control system comprises a transducer for receiving movement from a body part for generating a sensing signal associated with that movement. The sensing signal is processed by a linearizer for linearizing the sensing signal to be a linear function of the magnitude of the distance moved by the body part. The linearized sensing signal is normalized to be a function of the entire range of body part movement from the no-shrug position of the moveable body part. The normalized signal is divided into a plurality of discrete command signals. The discrete command signals are used by typical converter devices which are in operational association with the prosthetic device. The converter device uses the discrete command signals for driving the moveable portions of the prosthetic device and its sub-prosthesis. The method for controlling a prosthetic device associated with the present invention comprises the steps of receiving the movement from the body part, generating a sensing signal in association with the movement of the body part, linearizing the sensing signal to be a linear function of the magnitude of the distance moved by the body part, normalizing the linear signal to be a function of the entire range of the body part movement, dividing the normalized signal into a plurality of discrete command signals, and implementing the plurality of discrete command signals for driving the respective moveable prosthesis device and its sub-prosthesis.

  18. Optic disc oedema

    DEFF Research Database (Denmark)

    Nielsen, Marianne Kromann; Hamann, Steffen

    2014-01-01

    Optic disc oedema describes the nonspecific, localized swelling of the optic nerve head regardless of aetiology. Therefore, differentiating among the various aetiologies depends on a thorough history and knowledge of the clinical characteristics of the underlying conditions. Papilloedema strictly...... refers to optic disc oedema as a consequence of elevated intracranial pressure. It is usually a bilateral condition and visual function is preserved until late. Optic disc oedema caused by an anterior optic neuropathy is usually unilateral and accompanied by the loss of visual function....

  19. Internal Prosthetic Replacement of Skeletal Segments Lost in Combat Injuries.

    Science.gov (United States)

    1973-08-31

    osteo- articular bone grafts. Clin. Ortho., 87: 156, 1972. 8. Tuli, S. M.: Bridging of bone defects by massive bone grafts in tumorous conditions. Clin...fashion in its proximal one-third to "prevent distractic ,n of the fragments. The fiber metal segment was then placed in the appropriate defect and the...defect slightly oversized and also osteotomizing the fibula to delete any possible distracting forces or angulating forces. The only complication in

  20. The Bundle of His in Prosthetic Heart Valve Replacement*

    African Journals Online (AJOL)

    1973-01-27

    Jan 27, 1973 ... The tract has been slightly en- larged due to displacement of suture material during cutting of the section. (H. and E. x 4.) Group 1. Group 2. Controls. It is significant that recent haemorrhage within the conduction system was only found in patients belonging to group 1 (Tables II and IV). Such haemorrhage is.

  1. Herniated Cervical Disc

    Science.gov (United States)

    ... are sometimes prescribed for more severe arm and neck pain because of their very powerful anti-inflammatory effect. ... caused by a herniated cervical disc. However, some neck pain may persist. Most patients respond well to discectomy; ...

  2. Coronary artery assessment by multidetector computed tomography in patients with prosthetic heart valves

    International Nuclear Information System (INIS)

    Habets, Jesse; Mali, Willem P.T.M.; Budde, Ricardo P.J.; Brink, Renee B.A. van den; Uijlings, Ruben; Spijkerboer, Anje M.; Chamuleau, Steven A.J.

    2012-01-01

    Patients with prosthetic heart valves may require assessment for coronary artery disease. We assessed whether valve artefacts hamper coronary artery assessment by multidetector CT. ECG-gated or -triggered CT angiograms were selected from our PACS archive based on the presence of prosthetic heart valves. The best systolic and diastolic axial reconstructions were selected for coronary assessment. Each present coronary segment was scored for the presence of valve-related artefacts prohibiting coronary artery assessment. Scoring was performed in consensus by two observers. Eighty-two CT angiograms were performed on a 64-slice (n = 27) or 256-slice (n = 55) multidetector CT. Eighty-nine valves and five annuloplasty rings were present. Forty-three out of 1160 (3.7%) present coronary artery segments were non-diagnostic due to valve artefacts (14/82 patients). Valve artefacts were located in right coronary artery (15/43; 35%), left anterior descending artery (2/43; 5%), circumflex artery (14/43; 32%) and marginal obtuse (12/43; 28%) segments. All cobalt-chrome containing valves caused artefacts prohibiting coronary assessment. Biological and titanium-containing valves did not cause artefacts except for three specific valve types. Most commonly implanted prosthetic heart valves do not hamper coronary assessment on multidetector CT. Cobalt-chrome containing prosthetic heart valves preclude complete coronary artery assessment because of severe valve artefacts. circle Most commonly implanted prosthetic heart valves do not hamper coronary artery assessment circle Prosthetic heart valve composition determines the occurrence of prosthetic heart valve-related artefacts circle Bjoerk-Shiley and Sorin tilting disc valves preclude diagnostic coronary artery segment assessment. (orig.)

  3. Investigation of Product Performance of Al-Metal Matrix Composites Brake Disc using Finite Element Analysis

    International Nuclear Information System (INIS)

    Fatchurrohman, N; Marini, C D; Suraya, S; Iqbal, AKM Asif

    2016-01-01

    The increasing demand of fuel efficiency and light weight components in automobile sectors have led to the development of advanced material parts with improved performance. A specific class of MMCs which has gained a lot of attention due to its potential is aluminium metal matrix composites (Al-MMCs). Product performance investigation of Al- MMCs is presented in this article, where an Al-MMCs brake disc is analyzed using finite element analysis. The objective is to identify the potentiality of replacing the conventional iron brake disc with Al-MMCs brake disc. The simulation results suggested that the MMCs brake disc provided better thermal and mechanical performance as compared to the conventional cast iron brake disc. Although, the Al-MMCs brake disc dissipated higher maximum temperature compared to cast iron brake disc's maximum temperature. The Al-MMCs brake disc showed a well distributed temperature than the cast iron brake disc. The high temperature developed at the ring of the disc and heat was dissipated in circumferential direction. Moreover, better thermal dissipation and conduction at brake disc rotor surface played a major influence on the stress. As a comparison, the maximum stress and strain of Al-MMCs brake disc was lower than that induced on the cast iron brake disc. (paper)

  4. Control System for Prosthetic Devices

    Science.gov (United States)

    Bozeman, Richard J. (Inventor)

    1996-01-01

    A control system and method for prosthetic devices is provided. The control system comprises a transducer for receiving movement from a body part for generating a sensing signal associated with that of movement. The sensing signal is processed by a linearizer for linearizing the sensing signal to be a linear function of the magnitude of the distance moved by the body part. The linearized sensing signal is normalized to be a function of the entire range of body part movement from the no-shrug position of the moveable body part through the full-shrg position of the moveable body part. The normalized signal is divided into a plurality of discrete command signals. The discrete command signals are used by typical converter devices which are in operational association with the prosthetic device. The converter device uses the discrete command signals for driving the moveable portions of the prosthetic device and its sub-prosthesis. The method for controlling a prosthetic device associated with the present invention comprises the steps of receiving the movement from the body part, generating a sensing signal in association with the movement of the body part, linearizing the sensing signal to be a linear function of the magnitude of the distance moved by the body part, normalizing the linear signal to be a function of the entire range of the body part movement, dividing the normalized signal into a plurality of discrete command signals, and implementing the plurality of discrete command signals for driving the respective moveable prosthesis device and its sub-prosthesis.

  5. Prosthetics & Orthotics Manufacturing Initiative (POMI)

    Science.gov (United States)

    2012-12-21

    suspension system, socket- ankle /knee interface, etc.) associated with a complete prosthetic system. More specific, the purpose of these deliverables was...strap. The waist belt consists of an adjustable belt utilizing polypropylene buckles and a 2‖ elastic suspension strap which descends to the anchor ...Superior View. Step 8: The suspension component consists of a 1’ anchor strap with a buckle and a 5’ – 6’ long shoulder strap with hook and

  6. The Correlation between Insertion Depth of Prodisc-C Artificial Disc and Postoperative Kyphotic Deformity: Clinical Importance of Insertion Depth of Artificial Disc.

    Science.gov (United States)

    Lee, Do-Youl; Kim, Se-Hoon; Suh, Jung-Keun; Cho, Tai-Hyoung; Chung, Yong-Gu

    2012-09-01

    This study was designed to investigate the correlation between insertion depth of artificial disc and postoperative kyphotic deformity after Prodisc-C total disc replacement surgery, and the range of artificial disc insertion depth which is effective in preventing postoperative whole cervical or segmental kyphotic deformity. A retrospective radiological analysis was performed in 50 patients who had undergone single level total disc replacement surgery. Records were reviewed to obtain demographic data. Preoperative and postoperative radiographs were assessed to determine C2-7 Cobb's angle and segmental angle and to investigate postoperative kyphotic deformity. A formula was introduced to calculate insertion depth of Prodisc-C artificial disc. Statistical analysis was performed to search the correlation between insertion depth of Prodisc-C artificial disc and postoperative kyphotic deformity, and to estimate insertion depth of Prodisc-C artificial disc to prevent postoperative kyphotic deformity. In this study no significant statistical correlation was observed between insertion depth of Prodisc-C artificial disc and postoperative kyphotic deformity regarding C2-7 Cobb's angle. Statistical correlation between insertion depth of Prodisc-C artificial disc and postoperative kyphotic deformity was observed regarding segmental angle (p<0.05). It failed to estimate proper insertion depth of Prodisc-C artificial disc effective in preventing postoperative kyphotic deformity. Postoperative segmental kyphotic deformity is associated with insertion depth of Prodisc-C artificial disc. Anterior located artificial disc leads to lordotic segmental angle and posterior located artificial disc leads to kyphotic segmental angle postoperatively. But C2-7 Cobb's angle is not affected by artificial disc location after the surgery.

  7. Disc-halo interactions in ΛCDM

    Science.gov (United States)

    Bauer, Jacob S.; Widrow, Lawrence M.; Erkal, Denis

    2018-05-01

    We present a new method for embedding a stellar disc in a cosmological dark matter halo and provide a worked example from a Λ cold dark matter zoom-in simulation. The disc is inserted into the halo at a redshift z = 3 as a zero-mass rigid body. Its mass and size are then increased adiabatically while its position, velocity, and orientation are determined from rigid-body dynamics. At z = 1, the rigid disc (RD) is replaced by an N-body disc whose particles sample a three-integral distribution function (DF). The simulation then proceeds to z = 0 with live disc (LD) and halo particles. By comparison, other methods assume one or more of the following: the centre of the RD during the growth phase is pinned to the minimum of the halo potential, the orientation of the RD is fixed, or the live N-body disc is constructed from a two rather than three-integral DF. In general, the presence of a disc makes the halo rounder, more centrally concentrated, and smoother, especially in the innermost regions. We find that methods in which the disc is pinned to the minimum of the halo potential tend to overestimate the amount of adiabatic contraction. Additionally, the effect of the disc on the subhalo distribution appears to be rather insensitive to the disc insertion method. The LD in our simulation develops a bar that is consistent with the bars seen in late-type spiral galaxies. In addition, particles from the disc are launched or `kicked up' to high galactic latitudes.

  8. Ankle replacement

    Science.gov (United States)

    Ankle arthroplasty - total; Total ankle arthroplasty; Endoprosthetic ankle replacement; Ankle surgery ... Ankle replacement surgery is most often done while you are under general anesthesia. This means you will ...

  9. Novel imaging strategies for the Detection of Prosthetic Heart Valve Obstruction and Endocarditis

    NARCIS (Netherlands)

    Tanis, W.

    2014-01-01

    Valvular heart disease is accompanied by a high mortality/morbidity and often requires prosthetic heart valve (PHV) replacement in order to improve quality of life and survival. The major drawback of both mechanical and biological PHV implantations is development of dysfunction, which is a life

  10. The Gore-Tex prosthetic ligament as a salvage procedure in deficient knees

    NARCIS (Netherlands)

    Roolker, W.; Patt, T. W.; van Dijk, C. N.; Vegter, M.; Marti, R. K.

    2000-01-01

    The purpose of this study was to evaluate the results of prosthetic ligament replacement of the anterior cruciate ligament (ACL) or posterior cruciate ligament (PCL) with the Gore-Tex polytetrafluorethyene prosthesis (W.L. Gore and Co., Flagstaff, Ariz. ) in 52 patients (54 knees). All patients

  11. Infective endocarditis following transcatheter aortic valve replacement-

    DEFF Research Database (Denmark)

    Loh, Poay Huan; Bundgaard, Henning; S�ndergaard, Lars

    2013-01-01

    Transcatheter aortic valve replacement (TAVR) can improve the symptoms and prognosis of patients with severe aortic stenosis who, due to a high expected operative risk, would not have otherwise been treated surgically. If these patients develop prosthetic valve endocarditis, their presentations may...... be atypical causing a delay in the diagnosis and treatment. The management is also complicated by their comorbidities, and surgical treatment may not be feasible leading to a significant morbidity and mortality. We describe a case of an 85-year-old man with TAVI prosthetic valve endocarditis successfully...

  12. Computer Aided Facial Prosthetics Manufacturing System

    Directory of Open Access Journals (Sweden)

    Peng H.K.

    2016-01-01

    Full Text Available Facial deformities can impose burden to the patient. There are many solutions for facial deformities such as plastic surgery and facial prosthetics. However, current fabrication method of facial prosthetics is high-cost and time consuming. This study aimed to identify a new method to construct a customized facial prosthetic. A 3D scanner, computer software and 3D printer were used in this study. Results showed that the new developed method can be used to produce a customized facial prosthetics. The advantages of the developed method over the conventional process are low cost, reduce waste of material and pollution in order to meet the green concept.

  13. Circuit For Control Of Electromechanical Prosthetic Hand

    Science.gov (United States)

    Bozeman, Richard J., Jr.

    1995-01-01

    Proposed circuit for control of electromechanical prosthetic hand derives electrical control signals from shoulder movements. Updated, electronic version of prosthesis, that includes two hooklike fingers actuated via cables from shoulder harness. Circuit built around favored shoulder harness, provides more dexterous movement, without incurring complexity of computer-controlled "bionic" or hydraulically actuated devices. Additional harness and potentiometer connected to similar control circuit mounted on other shoulder. Used to control stepping motor rotating hand about prosthetic wrist to one of number of angles consistent with number of digital outputs. Finger-control signals developed by circuit connected to first shoulder harness transmitted to prosthetic hand via sliprings at prosthetic wrist joint.

  14. The Galactic stellar disc

    International Nuclear Information System (INIS)

    Feltzing, S; Bensby, T

    2008-01-01

    The study of the Milky Way stellar discs in the context of galaxy formation is discussed. In particular, we explore the properties of the Milky Way disc using a new sample of about 550 dwarf stars for which we have recently obtained elemental abundances and ages based on high-resolution spectroscopy. For all the stars we also have full kinematic information as well as information about their stellar orbits. We confirm results from previous studies that the thin and the thick discs have distinct abundance patterns. But we also explore a larger range of orbital parameters than what has been possible in our previous studies. Several new results are presented. We find that stars that reach high above the Galactic plane and have eccentric orbits show remarkably tight abundance trends. This implies that these stars formed out of well-mixed gas that had been homogenized over large volumes. We find some evidence that suggest that the event that most likely caused the heating of this stellar population happened a few billion years ago. Through a simple, kinematic exploration of stars with super-solar [Fe/H], we show that the solar neighbourhood contains metal-rich, high velocity stars that are very likely associated with the thick disc. Additionally, the HR1614 moving group and the Hercules and Arcturus stellar streams are discussed and it is concluded that, probably, a large fraction of the groups and streams so far identified in the disc are the result of evolution and interactions within the stellar disc rather than being dissolved stellar clusters or engulfed dwarf galaxies.

  15. Novel implant for peri-prosthetic proximal tibia fractures.

    Science.gov (United States)

    Tran, Ton; Chen, Bernard K; Wu, Xinhua; Pun, Chung Lun

    2018-03-01

    Repair of peri-prosthetic proximal tibia fractures is very challenging in patients with a total knee replacement or arthroplasty. The tibial component of the knee implant severely restricts the fixation points of the tibial implant to repair peri-prosthetic fractures. A novel implant has been designed with an extended flange over the anterior of tibial condyle to provide additional points of fixation, overcoming limitations of existing generic locking plates used for proximal tibia fractures. Furthermore, the screws fixed through the extended flange provide additional support to prevent the problem of subsidence of tibial component of knee implant. The design methodology involved extraction of bone data from CT scans into a flexible CAD format, implant design and structural evaluation and optimisation using FEM as well as prototype development and manufacture by selective laser melting 3D printing technology with Ti6Al4 V powder. A prototype tibia implant was developed based on a patient-specific bone structure, which was regenerated from the CT images of patient's tibia. The design is described in detail and being applied to fit up to 80% of patients, for both left and right sides based on the average dimensions and shape of the bone structure from a wide range of CT images. A novel tibial implant has been developed to repair peri-prosthetic proximal tibia fractures which overcomes significant constraints from the tibial component of existing knee implant. Copyright © 2018 Elsevier Ltd. All rights reserved.

  16. Isolated Optic Disc Tuberculosis

    Science.gov (United States)

    Mansour, Ahmad M.; Tabbara, Khalid F.; Tabbarah, Zuhair

    2015-01-01

    We present a healthy male subject who developed progressive visual loss in the left eye initially diagnosed as optic neuritis. Upon suspicion of infectious etiology, testing was positive for tuberculosis. There were no signs or symptoms of active systemic tuberculosis infection. The patient responded swiftly to antimycobacterial therapy with return of vision and resolution of disc swelling. Positive purified protein derivative skin test, negative chest radiograph, negative systemic workup, negative workup for other causes of unilateral optic neuritis and quick response to mycobacterial therapy reaffirm the entity of isolated optic disc tuberculosis similar to isolated choroidal tuberculosis without systemic manifestation. PMID:26483675

  17. Isolated Optic Disc Tuberculosis

    Directory of Open Access Journals (Sweden)

    Ahmad M. Mansour

    2015-09-01

    Full Text Available We present a healthy male subject who developed progressive visual loss in the left eye initially diagnosed as optic neuritis. Upon suspicion of infectious etiology, testing was positive for tuberculosis. There were no signs or symptoms of active systemic tuberculosis infection. The patient responded swiftly to antimycobacterial therapy with return of vision and resolution of disc swelling. Positive purified protein derivative skin test, negative chest radiograph, negative systemic workup, negative workup for other causes of unilateral optic neuritis and quick response to mycobacterial therapy reaffirm the entity of isolated optic disc tuberculosis similar to isolated choroidal tuberculosis without systemic manifestation.

  18. The Role of Virtual Articulator in Prosthetic and Restorative Dentistry

    Science.gov (United States)

    Aljanakh, Mohammad

    2014-01-01

    Virtual reality is a computer based technology linked with the future of dentistry and dental practice. The virtual articulator is one such application in prosthetic and restorative dentistry based on virtual reality that will significantly reduce the limitations of the mechanical articulator, and by simulation of real patient data, allow analyses with regard to static and dynamic occlusion as well as to jaw relation. It is the purpose of this article to present the concepts and strategies for a future replacement of the mechanical articulator by a virtual one. Also, a brief note on virtual reality haptic system has been highlighted along with newly developed touch enabled virtual articulator. PMID:25177664

  19. Prosthetic Valve Endocarditis - Successful Management With Antimicrobial Treatment

    Directory of Open Access Journals (Sweden)

    Ashokan Nambiar C

    2015-07-01

    Full Text Available Middle aged male was admitted with high fever, rigor and chills of 2 days duration. He was seen in the clinic two years back for syncope. He gave history of Mitral (Starr-Edward and Aortic (Medtronic valve replacement ten years earlier from another center and was on regular anticoagulation with dose-adjusted acenocoumarol. On evaluation he had normal prosthetic valve function by trans-thoracic echo, but Holter monitoring showed Paroxysmal Atrial Fibrillation. He had mild wall motion abnormalities and left ventricular dysfunction suggestive of coronary artery disease also and was put on additional Metoprolol.

  20. Cervical disc arthroplasty: Pros and cons.

    Science.gov (United States)

    Moatz, Bradley; Tortolani, P Justin

    2012-01-01

    Cervical disc arthroplasty has emerged as a promising potential alternative to anterior cervical discectomy and fusion (ACDF) in appropriately selected patients. Despite a history of excellent outcomes after ACDF, the question as to whether a fusion leads to adjacent segment degeneration remains unanswered. Numerous US investigational device exemption trials comparing cervical arthroplasty to fusion have been conducted to answer this question. This study reviews the current research regarding cervical athroplasty, and emphasizes both the pros and cons of arthroplasty as compared with ACDF. Early clinical outcomes show that cervical arthroplasty is as effective as the standard ACDF. However, this new technology is also associated with an expanding list of novel complications. Although there is no definitive evidence that cervical disc replacement reduces the incidence of adjacent segment degeneration, it does show other advantages; for example, faster return to work, and reduced need for postoperative bracing.

  1. Tracing Planets in Circumstellar Discs

    Directory of Open Access Journals (Sweden)

    Uribe Ana L.

    2013-04-01

    Full Text Available Planets are assumed to form in circumstellar discs around young stellar objects. The additional gravitational potential of a planet perturbs the disc and leads to characteristic structures, i.e. spiral waves and gaps, in the disc density profile. We perform a large-scale parameter study on the observability of these planet-induced structures in circumstellar discs in the (submm wavelength range for the Atacama Large (SubMillimeter Array (ALMA. On the basis of hydrodynamical and magneto-hydrodynamical simulations of star-disc-planet models we calculate the disc temperature structure and (submm images of these systems. These are used to derive simulated ALMA maps. Because appropriate objects are frequent in the Taurus-Auriga region, we focus on a distance of 140 pc and a declination of ≈ 20°. The explored range of star-disc-planet configurations consists of six hydrodynamical simulations (including magnetic fields and different planet masses, nine disc sizes with outer radii ranging from 9 AU to 225 AU, 15 total disc masses in the range between 2.67·10-7 M⊙ and 4.10·10-2 M⊙, six different central stars and two different grain size distributions, resulting in 10 000 disc models. At almost all scales and in particular down to a scale of a few AU, ALMA is able to trace disc structures induced by planet-disc interaction or the influence of magnetic fields in the wavelength range between 0.4...2.0 mm. In most cases, the optimum angular resolution is limited by the sensitivity of ALMA. However, within the range of typical masses of protoplane tary discs (0.1 M⊙...0.001 M⊙ the disc mass has a minor impact on the observability. At the distance of 140 pc it is possible to resolve discs down to 2.67·10-6 M⊙ and trace gaps in discs with 2.67·10-4 M⊙ with a signal-to-noise ratio greater than three. In general, it is more likely to trace planet-induced gaps in magneto-hydrodynamical disc models, because gaps are wider in the presence of

  2. Intraoperative echocardiography of a dislodged Björk-Shiley mitral valve disc.

    Science.gov (United States)

    Tanaka, M; Abe, T; Takeuchi, E; Watanabe, T; Tamaki, S

    1991-02-01

    The successful management of a patient who suffered an outlet strut fracture of a Björk-Shiley 60-degree convexo-concave mitral valve prosthesis is reported. Emergency operation was life-saving. Preoperative echocardiography assisted in making a prompt diagnosis, and intraoperative echocardiography allowed the detection and removal of the dislodged disc from the left ventricle at the time of the operation. The role of intraoperative echocardiography in the diagnosis of prosthetic strut fracture is emphasized.

  3. Knee Replacement

    Science.gov (United States)

    Knee replacement is surgery for people with severe knee damage. Knee replacement can relieve pain and allow you to ... Your doctor may recommend it if you have knee pain and medicine and other treatments are not ...

  4. Prosthetic

    Directory of Open Access Journals (Sweden)

    Pokpong Amornvit

    2014-01-01

    Full Text Available Ocular trauma can be caused by road traffic accidents, falls, assaults, or work-related accidents. Enucleation is often indicated after ocular injury or for the treatment of intraocular tumors, severe ocular infections, and painful blind eyes. Rehabilitation of an enucleated socket without an intraocular implant or with an inappropriately sized implant can result in superior sulcus deepening, enophthalmos, ptosis, ectropion, and lower lid laxity, which are collectively known as post-enucleation socket syndrome. This clinical report describes the rehabilitation of post-enucleation socket syndrome with a modified ocular prosthesis. Modifications to the ocular prosthesis were performed to correct the ptosis, superior sulcus deepening, and enophthalmos. The rehabilitation procedure produced satisfactory results.

  5. Aortic allografts in treatment of aortic valve and ascending aorta prosthetic endocarditis

    Directory of Open Access Journals (Sweden)

    S.V. Spiridonov

    2017-03-01

    Full Text Available The aim – to assess short- and long-term results of aortic root replacement using aortic allografts in patients with prosthetic endocarditis. Materials and methods. Since February 2009 until June 2016 aortic valve and ascending aorta replacement using aortic allografts was performed in 26 patients with prosthetic endocarditis. In 50 % of cases at initial operation aortic valve replacement was performed, in another 50 % of cases – aortic valve and ascending aorta replacement. Echocardiography was performed 10 days, 3, 6 and 12 months, 2, 3 and 5 years after surgery. Analysis of long-term results included all cases of deaths, prosthesis-related complications and recurrence of endocarditis. Results. 30-day mortality was 23.1 %. Extracorporeal membranous oxygenation (ECMO was used only in 5 patients (19.2 %. Four patients were weaned from ECMO. We did not observe any allograft-related complications. During follow-up period there were no cases of reoperation due to structural allograft failure. Relapse of infection occurred in 1 patient (3.8 % four years after the operation and led to lethal outcome. Conclusion. Reoperations using allografts are an effective surgical treatment of prosthetic endocarditis. In majority of cases prosthetic endocarditis was caused by gram-positive cocci (Staphylococcus. In 84.6 % of cases it was associated with destruction of paravalvular structures and abscesses formation. Heart failure was a causative factor of different complications in these patients, which required ECMO in 19.2 % of patients. In 80 % of cases patients were weaned from ECMO. Allografts using for the treatment of prosthetic endocarditis is associated with high resistance to infection and with a significant rate of freedom from recurrence of endocarditis within 3 years after surgery.

  6. Fungal prosthetic valve endocarditis with mycotic aneurysm: Case report.

    Science.gov (United States)

    Brandão, Mariana; Almeida, Jorge; Ferraz, Rita; Santos, Lurdes; Pinho, Paulo; Casanova, Jorge

    2016-09-01

    Fungal prosthetic valve endocarditis is an extremely severe form of infective endocarditis, with poor prognosis and high mortality despite treatment. Candida albicans is the most common etiological agent for this rare but increasingly frequent condition. We present a case of fungal prosthetic valve endocarditis due to C. albicans following aortic and pulmonary valve replacement in a 38-year-old woman with a history of surgically corrected tetralogy of Fallot, prior infective endocarditis and acute renal failure with need for catheter-based hemodialysis. Antifungal therapy with liposomal amphotericin B was initiated prior to cardiac surgery, in which the bioprostheses were replaced by homografts, providing greater resistance to recurrent infection. During hospitalization, a mycotic aneurysm was diagnosed following an episode of acute arterial ischemia, requiring two vascular surgical interventions. Despite the complications, the patient's outcome was good and she was discharged on suppressive antifungal therapy with oral fluconazole for at least a year. The reported case illustrates multiple risk factors for fungal endocarditis, as well as complications and predictors of poor prognosis, demonstrating its complexity. Copyright © 2016 Sociedade Portuguesa de Cardiologia. Publicado por Elsevier España, S.L.U. All rights reserved.

  7. Prosthetic joint infection: state-of-the-art

    Directory of Open Access Journals (Sweden)

    Boris Sergeyevich Belov

    2013-01-01

    Full Text Available In current clinical practice, joint replacement is one of the progressive and permanently developed surgical treatments in patients with locomotor injury of any genesis. However, the upward trend in the number of replacements is inevitably accompanied by the rising number of patients with periprosthetic joint infection. The polymorphism of its clinical picture and the nonspecificity of diagnostic tests lead to a frequent delay in the diagnosis of prosthetic joint infection (PJI and thus late treatment. This paper gives an update on the etiology, epidemiology, clinical presentation, and diagnosis of PJI. Emphasis is laid on the value of a multimodal approach to PJI treatment Р a combination of surgery and etiotropic antibiotic therapy. The choice of a treatment modality is determined by patient status, comorbidity, and the magnitude and duration of the infectious process.

  8. Wave disc engine apparatus

    Energy Technology Data Exchange (ETDEWEB)

    Muller, Norbert; Piechna, Janusz; Sun, Guangwei; Parraga, Pablo-Francisco

    2018-01-02

    A wave disc engine apparatus is provided. A further aspect employs a constricted nozzle in a wave rotor channel. A further aspect provides a sharp bend between an inlet and an outlet in a fluid pathway of a wave rotor, with the bend being spaced away from a peripheral edge of the wave rotor. A radial wave rotor for generating electricity in an automotive vehicle is disclosed in yet another aspect.

  9. Clinical characteristics, microbiology, and outcomes of prosthetic joint infection in Taiwan.

    Science.gov (United States)

    Tsai, Jen-Chih; Sheng, Wang-Huei; Lo, Wan-Yu; Jiang, Ching-Chuan; Chang, Shan-Chwen

    2015-04-01

    Prosthetic joint infection (PJI) after total knee or hip replacement is a devastating complication associated with substantial morbidity and economic cost. The incidence of prosthetic joint infection is increasing as the use of mechanical joint replacement increases. The treatment approach to prosthetic joint infection is based on different clinical situations such as a patient's comorbidities, epidemic microbiology data, and surgical procedures. The aim of our study was to understand clinical characteristics of prosthetic joint infection, the microbiology of the prosthetic joint infection, and the outcomes of different treatment strategies during 2006-2011. We retrospectively collected cases of prosthetic joint infection in the National Taiwan University Hospital between January 1, 2006 and December 31, 2011. The patients' characteristics, microbiology, outcomes, and factors associated with treatment success were recorded. One hundred and forty-four patients were identified as having PJI. Of these, 92 patients were entered into per-protocol analysis. Staphylococcus aureus was the most common causative organism (29.9%), followed by coagulase-negative Staphylococci (16.7%), and Enterococci (9.7%). The overall treatment success rate was 50%. Patients who received a two-stage revision had a better outcome, compared to patients who underwent other types of surgeries (70% vs. 32.7%, respectively; p < 0.001). In multivariate analysis, the two-stage revision was significantly associated with treatment success (odds ratio = 3.923, 95% confidence interval = 1.53-10.04). Our study demonstrates that Staphylococcus aureus was the most common causative organisms in PJI. Performing two-stage revisions was significantly associated with a better outcome. Copyright © 2013. Published by Elsevier B.V.

  10. ISASS Policy Statement – Lumbar Artificial Disc

    Science.gov (United States)

    Garcia, Rolando

    2015-01-01

    Purpose The primary goal of this Policy Statement is to educate patients, physicians, medical providers, reviewers, adjustors, case managers, insurers, and all others involved or affected by insurance coverage decisions regarding lumbar disc replacement surgery. Procedures This Policy Statement was developed by a panel of physicians selected by the Board of Directors of ISASS for their expertise and experience with lumbar TDR. The panel's recommendation was entirely based on the best evidence-based scientific research available regarding the safety and effectiveness of lumbar TDR. PMID:25785243

  11. [Tuberculous prosthetic knee joint infection: a case report and literature review].

    Science.gov (United States)

    Lara-Oya, A; Liébana-Martos, M C; Rodríguez-Granger, J; Sampedro-Martínez, A; Aliaga-Martínez, L; Gutierrez-Fernández, J; Navarro-Marí, J M

    2016-08-01

    Prosthetic late infection occurs in the second month after surgery in the context of haematogenous spread from another source. Prosthetic mycobacterial infection is a rare complication whose clinical management is not standardized. Patient of 77 years with no personal history except for diabetes and a prosthetic replacement of right knee with osteoarthritis three years ago. Patient goes to hospital emergency box for 6 months pain in the right knee with mechanical inflammatory signs but no fever associated. After their return within 5 days and clinical worsening is reporting growth of Mycobacterium tuberculosis in knee aspirate and antitubercular treatment is established for 9 months. Nuclear magnetic resonance imaging studies also confirmed the diagnosis of tuberculosis spondylitis in the clinical context of the patients. After surgery, M. tuberculosis was again isolated from intraoperative samples and therefore the patient received another batch of treatment for 9 months. After a year of monitoring, the development was acceptable but few months later, the patient died for cardiovascular causes. In the literature review, 15 publications with a total of 17 clinical cases of prosthetic infection by M. tuberculosis were found from 1980 to 2014. Prosthetic tuberculous arthritis, although it is a rare presentation, it should be noted, especially in patients with predisposing conditions with a history of tuberculosis infection.

  12. Accretion discs around neutron stars

    International Nuclear Information System (INIS)

    Pringle, J.E.

    1982-01-01

    If the central object in the disc is a neutron star, then we do not need the disc itself to produce the X-rays. In other words, the disc structure itself is not important as long as it plays the role of depositing matter on the neutron star at a sufficient rate to produce the X-ray flux. Similarly, in the outer disc regions, the main disc luminosity comes from absorption and reradiation of X-ray photons and not from the intrinsic, viscously-produced, local energy production rate. These two points indicate why in the compact binary X-ray sources confrontation between disc theory and observations is not generally practicable. For this reason I will divide my talk into two parts: one on observational discs in which I discuss what observational evidence there is for discs in the compact X-ray sources and what the evidence can tell the theorist about disc behaviour, and the other on theoretical discs where I consider in what ways theoretical arguments can put limits or cast doubt on some of the empirical models put forward to explain the observations. (orig.)

  13. Advanced upper limb prosthetic devices: implications for upper limb prosthetic rehabilitation.

    Science.gov (United States)

    Resnik, Linda; Meucci, Marissa R; Lieberman-Klinger, Shana; Fantini, Christopher; Kelty, Debra L; Disla, Roxanne; Sasson, Nicole

    2012-04-01

    The number of catastrophic injuries caused by improvised explosive devices in the Afghanistan and Iraq Wars has increased public, legislative, and research attention to upper limb amputation. The Department of Veterans Affairs (VA) has partnered with the Defense Advanced Research Projects Agency and DEKA Integrated Solutions to optimize the function of an advanced prosthetic arm system that will enable greater independence and function. In this special communication, we examine current practices in prosthetic rehabilitation including trends in adoption and use of prosthetic devices, financial considerations, and the role of rehabilitation team members in light of our experiences with a prototype advanced upper limb prosthesis during a VA study to optimize the device. We discuss key challenges in the adoption of advanced prosthetic technology and make recommendations for service provision and use of advanced upper limb prosthetics. Rates of prosthetic rejection are high among upper limb amputees. However, these rates may be reduced with sufficient training by a highly specialized, multidisciplinary team of clinicians, and a focus on patient education and empowerment throughout the rehabilitation process. There are significant challenges emerging that are unique to implementing the use of advanced upper limb prosthetic technology, and a lack of evidence to establish clinical guidelines regarding prosthetic prescription and treatment. Finally, we make recommendations for future research to aid in the identification of best practices and development of policy decisions regarding insurance coverage of prosthetic rehabilitation. Copyright © 2012 American Congress of Rehabilitation Medicine. Published by Elsevier Inc. All rights reserved.

  14. Acute Mitral Valve Dysfunction Due to Escape of Prosthetic Mechanical Leaflet and Peripheral Leaftlet Embolization.

    Science.gov (United States)

    Calik, Eyup Serhat; Limandal, Husnu Kamil; Arslan, Umit; Tort, Mehmet; Yildiz, Ziya; Bayram, Ednan; Dag, Ozgur; Kaygin, Mehmet Ali; Erkut, Bilgehan

    2015-12-14

    Leaflet escape of prosthetic valve is rare but potentially life threatening. Early diagnosis is essential on account of avoiding mortality, and emergency surgical correction is compulsory. This complication has previously been reported for both monoleaflet and bileaflet valve models. A 30-year-old man who had undergone mitral valve replacement with a bileaflet valve 8 years prior at another center was admitted with acute-onset with cardiogenic shock as an emergency case. Transthoracic echocardiograms showed acute-starting severe mitral regurgitation associated with prosthetic mitral valve. There was a suspicious finding of a single prosthetic mitral leaflet. But the problem related with the valve wasn't specifically determined. The patient underwent emergent surgery for replacement of the damaged prosthetic valves immediately. There was no tissue impingement and thrombosis, one of the two leaflets was absent, and there were no signs of endocarditis or pannus formation in the prosthetic valve. The missing leaflet could not be found within the cardiac cavity. The abdominal fluoroscopic study and plain radiography were unable to detect the escaped leaflet during surgery. The damaged valve was removed and a replacement 29 mm bileaflet mechanical valve was inserted by right lateral thoracotomy. After post-operative week one, the abdominal computed tomography scan and the ultrasound showed the escaped leaflet in the left femoral artery. Fifteen days after the surgery the escaped leaflet was removed safely from the left femoral artery and the patient made a complete recovery. The escaped leaflet showed a fracture of one of the pivot systems caused by structural failure. Early cardiac surgery should be applied because of life-threatening problems.

  15. Single-stage revision for fungal peri-prosthetic joint infection: a single-centre experience.

    Science.gov (United States)

    Klatte, T O; Kendoff, D; Kamath, A F; Jonen, V; Rueger, J M; Frommelt, L; Gebauer, M; Gehrke, T

    2014-04-01

    Fungal peri-prosthetic infections of the knee and hip are rare but likely to result in devastating complications. In this study we evaluated the results of their management using a single-stage exchange technique. Between 2001 and 2011, 14 patients (ten hips, four knees) were treated for a peri-prosthetic fungal infection. One patient was excluded because revision surgery was not possible owing to a large acetabular defect. One patient developed a further infection two months post-operatively and was excluded from the analysis. Two patients died of unrelated causes. After a mean of seven years (3 to 11) a total of ten patients were available for follow-up. One patient, undergoing revision replacement of the hip, had a post-operative dislocation. Another patient, undergoing revision replacement of the knee, developed a wound infection and required revision 29 months post-operatively following a peri-prosthetic femoral fracture. The mean Harris hip score increased to 74 points (63 to 84; p prosthetic infection is feasible, with an acceptable rate of a satisfactory outcome.

  16. DME Prosthetics Orthotics, and Supplies Fee Schedule

    Data.gov (United States)

    U.S. Department of Health & Human Services — Durable Medical Equipment, Prosthetics-Orthotics, and Supplies Fee Schedule. The list contains the fee schedule amounts, floors, and ceilings for all procedure codes...

  17. Computed Tomography of Prosthetic Heart Valves

    NARCIS (Netherlands)

    Habets, J.

    2012-01-01

    Prosthetic heart valve (PHV) dysfunction is an infrequent but potentially life-threatening disease with a heterogeneous clinical presentation. Patients with PHV dysfunction clinically can present with symptoms of congestive heart failure (dyspnea, fatigue, edema), fever, angina pectoris, dizziness

  18. CT discography for cervical soft disc hernia

    Energy Technology Data Exchange (ETDEWEB)

    Iwasa, Kenichi; Mizutani, Shigeru; Morimoto, Hiroyuki; Yamada, Hidehito; Iwasa, Satoru

    1985-03-01

    In this study the effectiveness of computed tomographic discography (CTD) in diagnosing cervical soft disc hernia was evaluated. Twenty-five intervertebral discs of 15 cases with cervical soft disc hernia were examined with a discography and then a CT scan. Results of the CT scan were as follows: three discs were protruded, 12 discs were prolapsed, 6 discs were extruded, and 4 discs were sequestrated. The findings were helpful in determining the location of soft disc hernias between the median and posterolateral discs. They were also valuable in classifying types of hernias and surgical approaches.

  19. CT discography for cervical soft disc hernia

    International Nuclear Information System (INIS)

    Iwasa, Kenichi; Mizutani, Shigeru; Morimoto, Hiroyuki; Yamada, Hidehito; Iwasa, Satoru

    1985-01-01

    In this study the effectiveness of computed tomographic discography (CTD) in diagnosing cervical soft disc hernia was evaluated. Twenty-five interververtebral discs of 15 cases with cervical soft disc hernia were examined with a discography and then a CT scan. Results of the CT scan were as follows: three discs were protruded, 12 discs were prolapsed, 6 discs were extruded, and 4 discs were sequestrated. The findings were helpful in determining the location of soft disc hernians between the median and posterolateral discs. They were also valuable in classifying types of hernians and surgical aproaches. (author)

  20. Isolated Lactobacillus chronic prosthetic knee infection.

    Science.gov (United States)

    Bennett, David M; Shekhel, Tatyana; Radelet, Matt; Miller, Michael D

    2014-01-01

    Lactobacillus is a gram-positive rod bacteria found primarily in the gastrointestinal and female genital tracts. Prosthetic infections in implants are being increasingly reported. The authors present a case of a 58-year-old patient with Lactobacillus septic prosthetic knee joint infection. To the authors’ knowledge, this is the first reported case of chronic prosthetic knee infection with isolated Lactobacillus species. Lactobacillus has been most commonly implicated with bacteremia and endocarditis and rarely with pneumonia, meningitis, and endovascular infection, and a vast majority of the cases are reported in immunocompromised patients. In the current case, diabetes mellitus, hepatitis, malnutrition, anemia, and liver failure were comorbid conditions, placing the patient at increased risk of infection. The findings suggest that further case series are necessary to establish the significance of Lactobacillus as an etiologic agent in chronic low-virulence, and potentially vancomycin-resistant, prosthetic joint infection. The need also exists for further research aimed at the risk of prosthetic joint infection with oral intake of certain probiotic foods and supplements. The goal of this case report is to bring to light the potential of this organism to be a cause of subtle chronic prosthetic joint infection.

  1. Efficacy and safety of Mobi-C cervical artificial disc versus anterior discectomy and fusion in patients with symptomatic degenerative disc disease: A meta-analysis.

    Science.gov (United States)

    Lu, Hui; Peng, Lihua

    2017-12-01

    Total disc replacement (TDR) using Mobi-C cervical artificial disc might be promising to treat symptomatic degenerative disc disease. However, the results remained controversial. We conducted a systematic review and meta-analysis to compare the efficacy and safety of Mobi-C cervical artificial disc and anterior cervical discectomy and fusion (ACDF) in patients with symptomatic degenerative disc disease. PubMed, EMbase, Web of science, EBSCO, and Cochrane library databases were systematically searched. Randomized controlled trials (RCTs) assessing the effect of Mobi-C versus ACDF on the treatment of symptomatic degenerative disc disease were included. Two investigators independently searched articles, extracted data, and assessed the quality of included studies. The primary outcomes were neck disability index (NDI) score, patient satisfaction, and subsequent surgical intervention. Meta-analysis was performed using the random-effect model. Four RCTs were included in the meta-analysis. Overall, compared with ACDF surgery for symptomatic degenerative disc disease, TDR using Mobi-C was associated with a significantly increased NDI score (Std. mean difference = 0.32; 95% CI = 0.10-0.53; P = .004), patient satisfaction (odds risk [OR] = 2.75; 95% confidence interval [CI] = 1.43-5.27; P = .002), and reduced subsequent surgical intervention (OR = 0.20; 95% CI = 0.11-0.37; P degenerative disc disease, TDR using Mobi-C cervical artificial disc resulted in a significantly improved NDI score, patient satisfaction, and reduced subsequent surgical intervention. There was no significant difference of neurological deterioration, radiographic success, and overall success between TDR using Mobi-C cervical artificial disc versus ACDF surgery. TDR using Mobi-C cervical artificial disc should be recommended for the treatment of symptomatic degenerative disc disease.

  2. Prosthetic joint infections: radionuclide state-of-the-art imaging

    Energy Technology Data Exchange (ETDEWEB)

    Gemmel, Filip [AZ Alma Campus Sijsele, Department of Nuclear Medicine, Sijsele-Damme (Belgium); Wyngaert, Hans van den [AZ Alma Campus Sijsele, Department of Orthopaedic Surgery, Sijsele-Damme (Belgium); Love, Charito [Albert Einstein College of Medicine of Yeshiva University, Division of Nuclear Medicine and Radiology, Bronx, NY (United States); Welling, M.M. [Leiden University Medical Center, Scientist Molecular Imaging, Department of Radiology, Section of Nuclear Medicine C2-203, Leiden (Netherlands); Gemmel, Paul [Ghent University, The Faculty of Economics and Business Administration, Ghent (Belgium); Palestro, Christopher J. [Hofstra North Shore-Long Island Jewish Health System, Division of Nuclear Medicine and Molecular Imaging, Department of Radiology, Hempstead, NY (United States)

    2012-05-15

    Prosthetic joint replacement surgery is performed with increasing frequency. Overall the incidence of prosthetic joint infection (PJI) and subsequently prosthesis revision failure is estimated to be between 1 and 3%. Differentiating infection from aseptic mechanical loosening, which is the most common cause of prosthetic failure, is especially important because of different types of therapeutic management. Despite a thorough patient history, physical examination, multiple diagnostic tests and complex algorithms, differentiating PJI from aseptic loosening remains challenging. Among imaging modalities, radiographs are neither sensitive nor specific and cross-sectional imaging techniques, such as computed tomography and magnetic resonance imaging, are limited by hardware-induced artefacts. Radionuclide imaging reflects functional rather than anatomical changes and is not hampered by the presence of a metallic joint prosthesis. As a result scintigraphy is currently the modality of choice in the investigation of suspected PJI. Unfortunately, there is no true consensus about the gold standard technique since there are several drawbacks and limitations inherent to each modality. Bone scintigraphy (BS) is sensitive for identifying the failed joint replacement, but cannot differentiate between infection and aseptic loosening. Combined bone/gallium scintigraphy (BS/GS) offers modest improvement over BS alone for diagnosing PJI. However, due to a number of drawbacks, BS/GS has generally been superseded by other techniques but it still may have a role in neutropenic patients. Radiolabelled leucocyte scintigraphy remains the gold standard technique for diagnosing neutrophil-mediated processes. It seems to be that combined in vitro labelled leucocyte/bone marrow scintigraphy (LS/BMS), with an accuracy of about 90%, is currently the imaging modality of choice for diagnosing PJI. There are, however, significant limitations using in vitro labelled leucocytes and considerable effort

  3. Prosthetic joint infections: radionuclide state-of-the-art imaging

    International Nuclear Information System (INIS)

    Gemmel, Filip; Wyngaert, Hans van den; Love, Charito; Welling, M.M.; Gemmel, Paul; Palestro, Christopher J.

    2012-01-01

    Prosthetic joint replacement surgery is performed with increasing frequency. Overall the incidence of prosthetic joint infection (PJI) and subsequently prosthesis revision failure is estimated to be between 1 and 3%. Differentiating infection from aseptic mechanical loosening, which is the most common cause of prosthetic failure, is especially important because of different types of therapeutic management. Despite a thorough patient history, physical examination, multiple diagnostic tests and complex algorithms, differentiating PJI from aseptic loosening remains challenging. Among imaging modalities, radiographs are neither sensitive nor specific and cross-sectional imaging techniques, such as computed tomography and magnetic resonance imaging, are limited by hardware-induced artefacts. Radionuclide imaging reflects functional rather than anatomical changes and is not hampered by the presence of a metallic joint prosthesis. As a result scintigraphy is currently the modality of choice in the investigation of suspected PJI. Unfortunately, there is no true consensus about the gold standard technique since there are several drawbacks and limitations inherent to each modality. Bone scintigraphy (BS) is sensitive for identifying the failed joint replacement, but cannot differentiate between infection and aseptic loosening. Combined bone/gallium scintigraphy (BS/GS) offers modest improvement over BS alone for diagnosing PJI. However, due to a number of drawbacks, BS/GS has generally been superseded by other techniques but it still may have a role in neutropenic patients. Radiolabelled leucocyte scintigraphy remains the gold standard technique for diagnosing neutrophil-mediated processes. It seems to be that combined in vitro labelled leucocyte/bone marrow scintigraphy (LS/BMS), with an accuracy of about 90%, is currently the imaging modality of choice for diagnosing PJI. There are, however, significant limitations using in vitro labelled leucocytes and considerable effort

  4. Cetacean Swimming with Prosthetic Limbs

    Science.gov (United States)

    Bode-Oke, Ayodeji; Ren, Yan; Dong, Haibo; Fish, Frank

    2016-11-01

    During entanglement in fishing gear, dolphins can suffer abrasions and amputations of flukes and fins. As a result, if the dolphin survives the ordeal, swimming performance is altered. Current rehabilitation technques is the use of prosthesis to regain swimming ability. In this work, analyses are focused on two dolphins with locomotive impairment; Winter (currently living in Clearwater Marine Aquarium in Florida) and Fuji (lived in Okinawa Churaumi Aquarium in Japan). Fuji lost about 75% of its fluke surface to necrosis (death of cells) and Winter lost its tail due to amputation. Both dolphins are aided by prosthetic tails that mimic the shape of a real dolphin tail. Using 3D surface reconstruction techniques and a high fidelity Computational Fluid Dynamics (CFD) flow solver, we were able to elucidate the kinematics and hydrodynamics and fluke deformation of these swimmers to clarify the effectiveness of prostheses in helping the dolphins regain their swimming ability. Associated with the performance, we identified distinct features in the wake structures that can explain this gap in the performance compared to a healthy dolphin. This work was supported by ONR MURI Grant Number N00014-14-1-0533.

  5. Uptake of radiolabeled leukocytes in prosthetic graft infection

    International Nuclear Information System (INIS)

    Serota, A.I.; Williams, R.A.; Rose, J.G.; Wilson, S.E.

    1981-01-01

    The utility of radionuclide labeled leukocytes in the demonstration of infection within vascular prostheses was examined. The infrarenal aorta was replaced with a 3 cm Dacron graft in 12 dogs. On the third postoperative day, six of the animals received an intravenous injection of 10(8) Staphylococcus aureus. Labeled leukocyte scans were performed at postoperative days one and three, and then weekly for 8 weeks with indium-111 and technetium-99 labeled autologous leukocytes. When scans showed focal uptake of isotope in the area of prosthetic material, the grafts were aseptically excised and cultured on mannitol-salt agar. Both control and infected animals had retroperitoneal isotope activity in the immediate postoperative period that disappeared by the end of the first week. By the eighth postoperative week, all of the animals that received the bacteremic challenge had both radionuclide concentration in the region of the vascular prosthesis and S. aureus cultured subsequently from the perigraft tissues. None of the control animals had either radionuclide or bacteriologic evidence of infection at the eighth postoperative week. The radiolabeled leukocyte scan is a highly sensitive and specific technique, clinically applicable for the diagnosis of vascular prosthetic infections

  6. Leukocyte and bacteria imaging in prosthetic joint infection

    Directory of Open Access Journals (Sweden)

    AWJM Glaudemans

    2013-01-01

    Full Text Available There has been a significant increase in the number of joint prosthesis replacements worldwide. Although relatively uncommon, complications can occur with the most serious being an infection. Various radiological and nuclear imaging techniques are available to diagnose prosthetic joint infections (PJI. In this review article, we describe the pathophysiology of PJI, the principles of nuclear medicine imaging and the differences between Single Photon Emission Computed Tomography (SPECT and Positron Emission Tomography (PET. The value of nuclear medicine techniques for clinical practice is also discussed.Then we provide an overview of the most often used radionuclide imaging techniques that may be helpful in diagnosing prosthetic joint infection: the 67Ga-citrate, labelled white blood cells in vitro and in vivo (monoclonal antibodies directed against specific targets on the leukocytes, and 18F-fluorodeoxyglucose (18F-FDG. We describe their working methods, the pitfalls, and the interpretation criteria. Furthermore, we review recent advances in imaging bacteria, a molecular imaging method that holds promises for the detection of occult infections. We conclude proposing two diagnostic flow-charts, based on data in the literature, that could help the clinicians to choose the best nuclear imaging method when they have a patient with suspicion of or with proven PJI.

  7. Gravitating discs around black holes

    International Nuclear Information System (INIS)

    Karas, V; Hure, J-M; Semerak, O

    2004-01-01

    Fluid discs and tori around black holes are discussed within different approaches and with the emphasis on the role of disc gravity. First reviewed are the prospects of investigating the gravitational field of a black hole-disc system using analytical solutions of stationary, axially symmetric Einstein equations. Then, more detailed considerations are focused to the middle and outer parts of extended disc-like configurations where relativistic effects are small and the Newtonian description is adequate. Within general relativity, only a static case has been analysed in detail. Results are often very inspiring. However, simplifying assumptions must be imposed: ad hoc profiles of the disc density are commonly assumed and the effects of frame-dragging are completely lacking. Astrophysical discs (e.g. accretion discs in active galactic nuclei) typically extend far beyond the relativistic domain and are fairly diluted. However, self-gravity is still essential for their structure and evolution, as well as for their radiation emission and the impact on the surrounding environment. For example, a nuclear star cluster in a galactic centre may bear various imprints of mutual star-disc interactions, which can be recognized in observational properties, such as the relation between the central mass and stellar velocity dispersion. (topical review)

  8. The clinical significance of perivalvular pannus in prosthetic mitral valves: Can cardiac CT be helpful?

    Science.gov (United States)

    Chang, Suyon; Suh, Young Joo; Han, Kyunghwa; Kim, Jin Young; Kim, Young Jin; Chang, Byung-Chul; Choi, Byoung Wook

    2017-12-15

    The clinical significance of pannus in the prosthetic mitral valve (MV) is not well documented. To investigate the clinical significance of pannus on cardiac computed tomography (CT) in patients with a prosthetic MV. A total of 130 patients with previous MV replacement who underwent cardiac CT were retrospectively included in this study. The presence of pannus, paravalvular leak (PVL) around the prosthetic MV and limitation of motion (LOM) of the MV were analyzed using CT. Between patients with MV pannus and those without pannus, CT, echocardiographic, and redo-surgery findings were compared. The diagnostic performance of CT and transesophageal echocardiography (TEE) for the detection of MV pannus was also compared, using surgical findings as a standard reference. MV pannus was observed on cardiac CT in 32.3% of the study population. Patients with MV pannus detected on CT more commonly had LOM (28.2% vs. 15.2%) and less frequently had PVL of the prosthetic MV (16.7% vs. 25%) than patients without MV pannus (P>0.05). Prosthetic valve obstruction (PVO) due prosthetic MV pannus requiring redo-surgery was present in only five patients (11.9%). Cardiac CT detected MV pannus with sensitivity of 65.2% and specificity of 80.9% and showed better diagnostic performance than TEE (Ppannus can frequently be seen on cardiac CT. However, its clinical significance should be assessed with careful consideration, because PVO due to MV pannus is relatively uncommon, and pannus can be seen in patients without any clinical problems. Copyright © 2017 Elsevier B.V. All rights reserved.

  9. Esthetic management of compromised ridge in the anterior maxilla, a modified prosthetic approach

    Directory of Open Access Journals (Sweden)

    R Lambodharan

    2017-01-01

    Full Text Available Replacing a missing tooth with an implant, especially in the esthetic zone has been increasing demand for the patient. Placing dental implants in the esthetic zone, especially in the compromised ridge with thin gingival thin biotype is considered to be the ultimate challenge for many dentists. This case report illustrates the implant placement in the traumatic anterior maxilla with thin gingival biotype (Class IV and a modified approach in prosthetic placement.

  10. Evaluation of a Musculoskeletal Model with Prosthetic Knee through Six Experimental Gait Trials

    OpenAIRE

    Kia, Mohammad; Stylianou, Antonis P.; Guess, Trent M.

    2014-01-01

    Knowledge of the forces acting on musculoskeletal joint tissues during movement benefits tissue engineering, artificial joint replacement, and our understanding of ligament and cartilage injury. Computational models can be used to predict these internal forces, but musculoskeletal models that simultaneously calculate muscle force and the resulting loading on joint structures are rare. This study used publicly available gait, skeletal geometry, and instrumented prosthetic knee loading data [1]...

  11. Mitral valve-sparing procedures and prosthetic heart valve failure: A case report

    Science.gov (United States)

    Khan, Nasir A; Butany, Jagdish; Leong, Shaun W; Rao, Vivek; Cusimano, Robert J; Ross, Heather J

    2009-01-01

    Prosthetic heart valve dysfunction due to thrombus or pannus formation can be a life-threatening complication. The present report describes a 47-year-old woman who developed valvular cardiomyopathy after chorda-sparing mitral valve replacement, and subsequently underwent heart transplantation for progressive heart failure. The explanted mitral valve prosthesis showed significant thrombus and pannus leading to reduced leaflet mobility and valvular stenosis. The present report illustrates the role of the subvalvular apparatus and pannus in prosthesis dysfunction. PMID:19279993

  12. Prosthetic rehabilitation of severe Siebert's Class III defect with modified Andrews bridge system

    OpenAIRE

    Rathee, Manu; Sikka, Neha; Jindal, Sahil; Kaushik, Ashutosh

    2015-01-01

    Prosthetic dentistry involves the replacement of missing and contiguous tissues with artificial substitutes to restore and maintain the oral functions, appearance, and health of the patient. The treatment of edentulous areas with ridge defects poses a challenging task for the dentist. Management of such cases involves a wide range of treatment options comprising mainly of surgical interventions and non surgical techniques such as use of removable, fixed or fixed- removable partial dentures. B...

  13. sup 99m Tc-labelled anti NCA-95 antibodies in prosthetic heart valve endocarditis

    Energy Technology Data Exchange (ETDEWEB)

    Bair, H J; Becker, W; Wolf, F [Dept. of Nuclear Medicine, Univ. Erlangen-Nuernberg, Erlangen (Germany); Volkholz, H J [Dept. of Internal Medicine 1, Univ. of Erlangen-Nuernberg, Erlangen (Germany)

    1991-08-01

    A 54-y old women with earlier replacement of the mitral and aortic valves and clinical signs of localized endocarditis was studied with {sup 99m}Tc-labelled anti NCA-95 antibody. Whereas echocardiographic findings were negative, increased radionuclide uptake was observed left parasternal over the mitral valve as a sign of prosthetic valve endocarditis. This result could be confirmed by a similar study with leukocytes labelled in vitro with {sup 111}In-oxine. (orig.).

  14. Prótese para substituição total de disco intervertebral: desenvolvimento de modelo computacional e análise por elementos finitos Prótese de reemplazo total del disco intervertebral: modelo de desarrollo computacional y análisis de elementos finitos Prosthesis for total intervertebral disc replacement: computacional model development and finite element analysis

    Directory of Open Access Journals (Sweden)

    Tiago Nunes Campello

    2009-03-01

    ón de su modelo virtual, seguido por el virtual mecánica de análisis de elementos finitos. RESULTADOS: la prótesis discal, fue diseñado con tres componentes, que son la parte superior de brida, la brida inferior y núcleo. Aplicando el criterio de von Mises solución virtual para el análisis, se constató que el núcleo de la prótesis es la más solicitada durante la compresión axial y la compresión y cortante. CONCLUSIÓN: por último, este estudio demuestra la viabilidad de elaborar un proyecto para la construcción de una prótesis para reemplazo total del disco intervertebral, a través de métodos computacionales ya consagrados en los proyectos de ingeniería mecánica, principalmente en automoción y sector aeroespacial.INTRODUCTION: the idea of an artificial intervertebral disc is not new. The studies of spinal arthroplasty prostheses are in developing, while new materials and technologies are developed to suply medical engineering projects. OBJECTIVE: to establish a methodology for product development on a project of prosthesis for total disc replacement, trough the use of computacional engineering tools. METHODS: the methodology of prosthesis development began with the definition of their virtual model, followed by the virtual mechanical analysis by finite element. RESULTS: the prosthesis is designed with three components: the top flange, bottom flange and the core. Applying the von Mises criterion for the virtual analysis solution, it was found that the core of the prosthesis is the most stressed component during axial compression and compression/shear. CONCLUSION: this study demonstrated that the development of a total disc replacement prosthesis is viable through computational methods already known in mechanical engineering projects, mainly in automotive and aeronautics.

  15. Replacing penalties

    Directory of Open Access Journals (Sweden)

    Vitaly Stepashin

    2017-01-01

    Full Text Available УДК 343.24The subject. The article deals with the problem of the use of "substitute" penalties.The purpose of the article is to identify criminal and legal criteria for: selecting the replacement punishment; proportionality replacement leave punishment to others (the formalization of replacement; actually increasing the punishment (worsening of legal situation of the convicted.Methodology.The author uses the method of analysis and synthesis, formal legal method.Results. Replacing the punishment more severe as a result of malicious evasion from serving accused designated penalty requires the optimization of the following areas: 1 the selection of a substitute punishment; 2 replacement of proportionality is serving a sentence other (formalization of replacement; 3 ensuring the actual toughening penalties (deterioration of the legal status of the convict. It is important that the first two requirements pro-vide savings of repression in the implementation of the replacement of one form of punishment to others.Replacement of punishment on their own do not have any specifics. However, it is necessary to compare them with the contents of the punishment, which the convict from serving maliciously evaded. First, substitute the punishment should assume a more significant range of restrictions and deprivation of certain rights of the convict. Second, the perfor-mance characteristics of order substitute the punishment should assume guarantee imple-mentation of the new measures.With regard to replacing all forms of punishment are set significant limitations in the application that, in some cases, eliminates the possibility of replacement of the sentence, from serving where there has been willful evasion, a stricter measure of state coercion. It is important in the context of the topic and the possibility of a sentence of imprisonment as a substitute punishment in cases where the original purpose of the strict measures excluded. It is noteworthy that the

  16. [Surgical treatment of thoracic disc herniation].

    Science.gov (United States)

    Hrabálek, L; Kalita, O; Langová, K

    2010-08-01

    The aim of this study was to compare the efficiency of different surgical approaches to thoracic disc herniation, and to show the role of segmental fusion and selection of an appropriate microsurgical decompression technique for the successful outcome of surgery. A group of 27 patients, 10 men and 17 women, between 31 and 70 years (average age, 49.33 years) were included in this prospective study. They underwent surgery for thoracic degeneration disc disease in the period from June 1994 to August 2008. In all patients, the severity of myelopathy was assessed using the grading Frankel system and JOA score, axial and radicular pain intensity was evaluated with VAS and ODI rating systems. The diagnosis was established on the basis of thoracic spine radiography, thoracic spine MRI and a CT scan of the segment. A total of 30 thoracic segments, in the range of Th4/Th5 to Th12/L1, were indicated for surgery. Localisation of the hernia was medial at 19 segments, mediolateral at three and lateral at eight segments. Soft disc herniation was found in 17 cases and hard disc protrusion at the remaining 13 segments. Surgery for significant myelopathy was carried out in 23 patients and for pain in four patients. According to the surgical procedure used, the patients were allocated to two groups: group A comprised 10 patients treated without disc replacement through a laminectomy or a costotransversectomy exposure, and group B consisted of 17 patients undergo- ing intersomatic fusion via a thoracotomy. Clinical and radiographic examinations were made at regular intervals for at least 1 year of follow-up. The results of clinical assessment, including JOA scores, JOA Recovery Rate, VAS scores at rest and after exercise and ODI, were statistically analysed for each group and compared. There was a statistically significant difference in JOA evaluation of myelopathy between the groups in group A, the mean JOA score declined from 7.9 to 7.0, i.e., -0.9 point, while in group B it

  17. Simplified Prosthetic Rehabilitation of a Patient after Oral Cancer Removal.

    Science.gov (United States)

    Kranjčić, Josip; Džakula, Nikola; Vojvodić, Denis

    2016-09-01

    The treatment of patients with oral cancer is complex: a multidisciplinary approach needs to be taken and maxillofacial and oral surgeons, an oncologist, a prosthodontist should be included, and a psychologist is often needed. This case report describes the prosthetic rehabilitation of a patient after surgical removal of oral cancer with obturator prosthesis. Resection cavity was located in central part of the hard palate and the condition belonged to Aramany class 3 maxillary defects. The two-step impression technique of denture bearing area was used and the resection of cavity was performed. A primary impression-the impression of denture bearing area was made using irreversible hydrocolloid material, while the second impression - the impression of resection cavity was made using condensation silicone material and obturator prosthesis framework. The obturator prosthesis replaced lost teeth, improved oral function and esthetics at minimal costs.

  18. Simplified Prosthetic Rehabilitation of a Patient after Oral Cancer Removal

    Directory of Open Access Journals (Sweden)

    Nikola Džakula

    2016-01-01

    Full Text Available The treatment of patients with oral cancer is complex: a multidisciplinary approach needs to be taken and maxillofacial and oral surgeons, an oncologist, a prosthodontist should be included, and a psychologist is often needed. This case report describes the prosthetic rehabilitation of a patient after surgical removal of oral cancer with obturator prosthesis. Resection cavity was located in central part of the hard palate and the condition belonged to Aramany class 3 maxillary defects. The two-step impression technique of denture bearing area and the resection cavity was performed. A primary impression- the impression of denture bearing area was made using irreversible hydrocolloid material, while the second impression – the impression of resection cavity was made using condensation silicone material and obturator prosthesis framework. The obturator prosthesis replaced lost teeth, improved oral function and esthetics at minimal costs.

  19. Mycobacterium smegmatis infection of a prosthetic total knee arthroplasty.

    Science.gov (United States)

    Saffo, Zaid; Ognjan, Anthony

    2016-01-01

    The most common organisms causing prosthetic knee joint infections are staphylococci. However, arthroplasty infections with atypical microbial pathogens, such as Mycobacteria can occur. Due to the rarity of mycobacterial prosthetic joint infections, diagnosis, treatment, and management of these atypical infections represent a clinical challenge. A 71-year old female post-operative day 40 after a left total knee arthroplasty was hospitalized secondary to left knee pain and suspected arthroplasty infection. She had failed outpatient oral antimicrobial treatment for superficial stitch abscess; and outpatient IV/Oral antimicrobials for a clinical postoperative septic bursitis. Ultimately, resection arthroplasty with operative tissue acid fast bacterial cultures demonstrated growth of the Mycobacterium smegmatis group. Post-operatively, she completed a combination course of oral doxycycline and levofloxacin and successfully completed a replacement arthroplasty with clinical and microbial resolution of the infection. To our knowledge, literature review demonstrates three case of knee arthroplasty infection caused by the Mycobacterium smegmatis group. Correspondingly, optimal surgical procedures and antimicrobial management including antimicrobial selection, treatment duration are not well defined. Presently, the best treatment options consists of two step surgical management including prosthesis hardware removal followed by extended antimicrobial therapy, followed by consideration for re-implantation arthroplasty. Our case illustrates importance of considering atypical mycobacterial infections in post-operative arthroplasty infections not responding to traditional surgical manipulations and antimicrobials. For an arthroplasty infection involving the atypical Mycobacterium smegmatis group, two step arthroplasty revision, including arthroplasty resection, with a combination of oral doxycycline and levofloxacin can lead to successful infection resolution, allowing for a

  20. The activL® Artificial Disc: a next-generation motion-preserving implant for chronic lumbar discogenic pain

    Science.gov (United States)

    Yue, James J; Garcia, Rolando; Miller, Larry E

    2016-01-01

    Degeneration of the lumbar intervertebral discs is a leading cause of chronic low back pain in adults. Treatment options for patients with chronic lumbar discogenic pain unresponsive to conservative management include total disc replacement (TDR) or lumbar fusion. Until recently, only two lumbar TDRs had been approved by the US Food and Drug Administration − the Charité Artificial Disc in 2004 and the ProDisc-L Total Disc Replacement in 2006. In June 2015, a next-generation lumbar TDR received Food and Drug Administration approval − the activL® Artificial Disc (Aesculap Implant Systems). Compared to previous-generation lumbar TDRs, the activL® Artificial Disc incorporates specific design enhancements that result in a more precise anatomical match and allow a range of motion that better mimics the healthy spine. The results of mechanical and clinical studies demonstrate that the activL® Artificial Disc results in improved mechanical and clinical outcomes versus earlier-generation artificial discs and compares favorably to lumbar fusion. The purpose of this report is to describe the activL® Artificial Disc including implant characteristics, intended use, surgical technique, postoperative care, mechanical testing, and clinical experience to date. PMID:27274317

  1. Double-disc gate valve

    International Nuclear Information System (INIS)

    Wheatley, S.J.

    1979-01-01

    The invention relates to an improvement in a conventional double-disc gate valve having a vertically movable gate assembly including a wedge, spreaders slidably engaged therewith, a valve disc carried by the spreaders. When the gate assembly is lowered to a selected point in the valve casing, the valve discs are moved transversely outward to close inlet and outlet ports in the casing. The valve includes hold-down means for guiding the disc-and-spreader assemblies as they are moved transversely outward and inward. If such valves are operated at relatively high differential pressures, they sometimes jam during opening. Such jamming has been a problem for many years in gate valves used in gaseous diffusion plants for the separation of uranium isotopes. The invention is based on the finding that the above-mentioned jamming results when the outlet disc tilts about its horizontal axis in a certain way during opening of the valve. In accordance with the invention, tilting of the outlet disc is maintained at a tolerable value by providing the disc with a rigid downwardly extending member and by providing the casing with a stop for limiting inward arcuate movement of the member to a preselected value during opening of the valve

  2. [Localized purpura revealing vascular prosthetic graft infection].

    Science.gov (United States)

    Boureau, A S; Lescalie, F; Cassagnau, E; Clairand, R; Connault, J

    2013-07-01

    Prosthetic graft infection after vascular reconstruction is a rare but serious complication. We report a case of infection occurring late after implantation of an iliofemoral prosthetic vascular graft. The Staphylococcus aureus infection was revealed by vascular purpura localized on the right leg 7 years after implantation of a vascular prosthesis. This case illustrates an uncommonly late clinical manifestation presenting as an acute infection 7 years after the primary operation. In this situation, the presentation differs from early infection, which generally occurs within the first four postoperative months. Diagnosis and treatment remain a difficult challenge because prosthetic graft infection is a potentially life-threatening complication. Morbidity and mortality rates are high. Here we detail specific aspects of the clinical and radiological presentation. Copyright © 2013 Elsevier Masson SAS. All rights reserved.

  3. Validation of the prosthetic esthetic index

    DEFF Research Database (Denmark)

    Özhayat, Esben B; Dannemand, Katrine

    2014-01-01

    OBJECTIVES: In order to diagnose impaired esthetics and evaluate treatments for these, it is crucial to evaluate all aspects of oral and prosthetic esthetics. No professionally administered index currently exists that sufficiently encompasses comprehensive prosthetic esthetics. This study aimed...... to validate a new comprehensive index, the Prosthetic Esthetic Index (PEI), for professional evaluation of esthetics in prosthodontic patients. MATERIAL AND METHODS: The content, criterion, and construct validity; the test-retest, inter-rater, and internal consistency reliability; and the sensitivity...... furthermore distinguish between participants and controls, indicating sufficient sensitivity. CONCLUSION: The PEI is considered a valid and reliable instrument involving sufficient aspects for assessment of the professionally evaluated esthetics in prosthodontic patients. CLINICAL RELEVANCE...

  4. Ten questions on prosthetic shoulder infection.

    Science.gov (United States)

    Pinder, Elizabeth M; Ong, Joshua Cy; Bale, R Stephen; Trail, Ian A

    2016-07-01

    Prosthetic shoulder infection can cause significant morbidity secondary to pain and stiffness. Symptoms may be present for years before diagnosis because clinical signs are often absent and inflammatory markers may be normal. An emerging common culprit, Propionibacterium acnes, is hard to culture and so prolonged incubation is necessary. A negative culture result does not always exclude infection and new synovial fluid biochemical markers such as α defensin are less sensitive than for lower limb arthroplasty. A structured approach is necessary when assessing patients for prosthetic shoulder joint infection. This includes history, examination, serum inflammatory markers, plain radiology and aspiration and/or biopsy. A classification for the likelihood of prosthetic shoulder infection has been described based on culture, pre-operative and intra-operative findings. Treatment options include antibiotic suppression, debridement with component retention, one-stage revision, two-stage revision and excision arthroplasty. Revision arthroplasty is associated with the best outcomes.

  5. Are galaxy discs optically thick?

    International Nuclear Information System (INIS)

    Disney, Michael; Davies, Jonathan; Phillipps, Steven

    1989-01-01

    We re-examine the classical optical evidence for the low optical depths traditionally assigned to spiral discs and argue that it is highly model-dependent and unconvincing. In particular, layered models with a physically thin but optically thick dust layer behave like optically thin discs. The opposite hypotheses, that such discs are optically thick is then examined in the light of modern evidence. We find it to be consistent with the near-infrared and IRAS observations, with the surface brightnesses, with the HI and CO column densities and with the Hα measurements. (author)

  6. Structural Integration and Control of Peerless Human-like Prosthetic Hand

    Science.gov (United States)

    Dave, Ankit; Muthu, P.; Karthikraj, V.; Latha, S.

    2018-04-01

    Limb damage can create severe disturbance in movement and operative abilities wherein the prosthetic rehabilitation has the potential to replace function and enhance the quality of life. This paper presents a humanlike prosthetic hand using such unique design concept of hand model using artificial bones, ligaments, and tendons controlled using Arduino. Amongst various platforms available, Arduino is known for its adaptability, adoration and low cost. The design of prosthetic hand has a unique structure with all carpal, metacarpal, and phalanges which are bones of the hand. These bones are attached to each other following the pattern of human hand using the polymeric rubber as a functioning ligament. Furthermore, this structure of finger is driven by tendons attached to all fingers and passes through the ligaments working as pulley resulting in more degrees of freedom. The motor can twitch the tendons to achieve the action of fingers. Thus the servos, controlled by an Arduino, are used to regulate the movement mechanism of the prosthetic hand.

  7. Bruxism and prosthetic treatment: a critical review.

    Science.gov (United States)

    Johansson, Anders; Omar, Ridwaan; Carlsson, Gunnar E

    2011-07-01

    Based on the findings from available research on bruxism and prosthetic treatment published in the dental literature, an attempt was made to draw conclusions about the existence of a possible relationship between the two, and its clinical relevance. MEDLINE/PubMed searches were conducted using the terms 'bruxism' and 'prosthetic treatment', as well as combinations of these and related terms. The few studies judged to be relevant were critically reviewed, in addition to papers found during an additional manual search of reference lists within selected articles. Bruxism is a common parafunctional habit, occurring both during sleep and wakefulness. Usually it causes few serious effects, but can do so in some patients. The etiology is multifactorial. There is no known treatment to stop bruxism, including prosthetic treatment. The role of bruxism in the process of tooth wear is unclear, but it is not considered a major cause. As informed by the present critical review, the relationship between bruxism and prosthetic treatment is one that relates mainly to the effect of the former on the latter. Bruxism may be included among the risk factors, and is associated with increased mechanical and/or technical complications in prosthodontic rehabilitation, although it seems not to affect implant survival. When prosthetic intervention is indicated in a patient with bruxism, efforts should be made to reduce the effects of likely heavy occlusal loading on all the components that contribute to prosthetic structural integrity. Failure to do so may indicate earlier failure than is the norm. Copyright © 2011 Japan Prosthodontic Society. Published by Elsevier Ltd. All rights reserved.

  8. Optimising the prescription of prosthetic technologies (opptec): Outcome measures for evidence based prosthetic practice and use

    LENUS (Irish Health Repository)

    Ryall, Dr Nicola

    2010-01-01

    This study provided a forum for patients and service providers to voice their opinions in what they believe to be the important predictors and outcomes involved in successful rehabilitation following limb loss. To develop a consensus on the most important outcomes and factors to address for both the lower limb and upper limb prosthetic prescription process, the above data relating to lower limb and upper prosthetics were subsequently used in the next phase of the research involving two Delphi surveys of 23 and 53 experts within the lower limb and upper limb amputation and prosthetic field respectively, including users, service providers and researchers.\\r\

  9. [Multiple agenesis and prosthetic restoration].

    Science.gov (United States)

    Renault, P

    1990-03-01

    Cases of multiple agenesia present some difficulties in the treatment planing. Three situations may be encountered: limited agenesia, restored by a fixed, bonded or cemented prosthesis, multiple uni- or bimaxillary agenesia without remaining of deciduous teeth, restored by a fixed, bonded or cemented prosthesis or the partial adjacent prosthesis, multiple uni- or bimaxillary agenesia with remaining of deciduous teeth, restored by means of a supra-dental prosthesis. The first two situations have been described in dental literature and are relatively easy to treat. The same is not true for the third situation, where the decision to keep the temporary teeth considerably increases the difficulty of prosthetic restoration. This subject will be illustrated by the presentation of a clinical case of multiple bi-maxillary agenesia. The patient has: on the maxilla: an absence of 9 permanent teeth (18, 15, 14, 12, 22, 23, 24, 25, 28) and the presence of 4 deciduous teeth (62, 63, 64, 65), on the mandible: an absence of all permanent teeth, with the exception of 36 and 46, and the remaining of 4 deciduous teeth (75, 73, 83, 84). The remaining of deciduous teeth and the presence of a very high inter-arch space led to opting for dental coverage so as to keep the deciduous teeth and a proper vertical dimension. The patient wished to solve his "problem" in the maxilla first, and is not wanting to undergo the extraction of his deciduous teeth. The following therapeutic proposal was adapted: On the maxilla, a three-step procedure: first step: building of metal copings on 13, 16 and 26 and metal-ceramic crowns on 11 and 21, second step: building of telescop crowns on 16 and 26 and clasps on 13, 11 and 21, third step: casting of the removable partial denture framework and soldering to the telescop crowns and clasps. On the mandible, a provisional restoration using a supra-dental resin removable partial denture with ceramic occlusal surfaces was adopted. The aesthetic and functional

  10. Mesofluidic controlled robotic or prosthetic finger

    Science.gov (United States)

    Lind, Randall F; Jansen, John F; Love, Lonnie J

    2013-11-19

    A mesofluidic powered robotic and/or prosthetic finger joint includes a first finger section having at least one mesofluidic actuator in fluid communication with a first actuator, a second mesofluidic actuator in fluid communication with a second actuator and a second prosthetic finger section pivotally connected to the first finger section by a joint pivot, wherein the first actuator pivotally cooperates with the second finger to provide a first mechanical advantage relative to the joint point and wherein the second actuator pivotally cooperates with the second finger section to provide a second mechanical advantage relative to the joint point.

  11. Tomographic and echocardiographic diagnosis of mitral prosthetic valve thrombosis

    International Nuclear Information System (INIS)

    Sainz Gonzalez de la Penna, Benito; Ramos Gutierrez, Luis Benito; Gonzalez Artiles, Iovank

    2010-01-01

    Despite the progress achieved in the design of mechanical prosthetic valves, prosthetic valve thrombosis remains a frequent cause of morbidity, usually due to incorrect anticoagulation. A patient was presented with mitral prosthetic thrombosis one year after implantation, who had been diagnosed by transthoracic transesophageal echocardiography imaging and 64-slice computed tomography. Thrombolytic therapy was successful and led to the satisfactory evolution of the patient

  12. Disc piezoelectric ceramic transformers.

    Science.gov (United States)

    Erhart, Jirií; Půlpán, Petr; Doleček, Roman; Psota, Pavel; Lédl, Vít

    2013-08-01

    In this contribution, we present our study on disc-shaped and homogeneously poled piezoelectric ceramic transformers working in planar-extensional vibration modes. Transformers are designed with electrodes divided into wedge, axisymmetrical ring-dot, moonie, smile, or yin-yang segments. Transformation ratio, efficiency, and input and output impedances were measured for low-power signals. Transformer efficiency and transformation ratio were measured as a function of frequency and impedance load in the secondary circuit. Optimum impedance for the maximum efficiency has been found. Maximum efficiency and no-load transformation ratio can reach almost 100% and 52 for the fundamental resonance of ring-dot transformers and 98% and 67 for the second resonance of 2-segment wedge transformers. Maximum efficiency was reached at optimum impedance, which is in the range from 500 Ω to 10 kΩ, depending on the electrode pattern and size. Fundamental vibration mode and its overtones were further studied using frequency-modulated digital holographic interferometry and by the finite element method. Complementary information has been obtained by the infrared camera visualization of surface temperature profiles at higher driving power.

  13. Knee Replacement

    Science.gov (United States)

    ... days. Medications prescribed by your doctor should help control pain. During the hospital stay, you'll be encouraged to move your ... exercise your new knee. After you leave the hospital, you'll continue physical ... mobility and a better quality of life. And most knee replacements can be ...

  14. Disc Golf: Teaching a Lifetime Activity

    Science.gov (United States)

    Eastham, Susan L.

    2015-01-01

    Disc golf is a lifetime activity that can be enjoyed by students of varying skill levels and abilities. Disc golf follows the principles of ball golf but is generally easier for students to play and enjoy success. The object of disc golf is similar to ball golf and involves throwing a disc from the teeing area to the target in as few throws as…

  15. Effects of cilostazol and k-134 on reconstructive surgery using prosthetic grafts in the abdominal aorta of beagle dogs.

    Science.gov (United States)

    Inoue, Yoshinori; Sugano, Norihide; Jibiki, Masatoshi; Kudo, Toshifumi; Iwai, Takehisa

    2008-01-01

    Problems associated with prosthetic graft replacement are stenosis at the anastomosis site and thrombus formation on the inner surface. Cilostazol is known to have antiplatelet activity and inhibit vascular smooth muscle cell proliferation and neointima thickening. A cilostazol derivative, (-)-6-[3-[3-cyclopropyl-3-[(1R,2R)-2-hydroxycyclohexyl]ureido]-propoxy]-2-(1H)-quinolinone (K-134), has more potent anti-platelet activity and anti-neointimal thickening activity than cilostazol in the in-vitro platelet aggregation and in-vivo anti-hyperplastic activity assay. The aim of this study was to investigate effects of cilostazol and K-134 on thrombus formation and neointimal thickening at the site of prosthetic graft replacement. Beagle dogs underwent infrarenal abdominal aortic resection with straight Dacron graft replacement, which were allocated to the control, cilostazol, and K-134 groups. Two dogs were dead without confirming the cause of death. After 6 months, all dogs were necropsied. All prosthetic grafts were patent in each group. Ratios of red thrombus to prosthetic graft area were 0.3+/-6.4%, and 3.3+/-4.5% in the cilostazol and K-134 groups, respectively, which were significant different from that in the control group (24.4+/-16.8%). However, no clear difference was seen among the 3 groups with respect to neointimal thickness (control group, 0.70+/-0.13 mm; cilostazol group, 0.59+/-0.14 mm; K-134 group, 0.67+/-0.14 mm). Cilostazol and K-134 significantly inhibited thrombus formation on the inner surface of the prosthetic graft at 6 months after graft replacement. Neointimal thickening on the inner surface was slight even in control-group animals, and the effects of cilostazol and K-134 on such thickening were unclear.

  16. Correctness of multi-detector-row computed tomography for diagnosing mechanical prosthetic heart valve disorders using operative findings as a gold standard

    Energy Technology Data Exchange (ETDEWEB)

    Tsai, I.Chen [Taichung Veterans General Hospital, Department of Radiology, Taichung (China); Institute of Clinical Medicine and Faculty of Medicine, National Yang-Ming University, Taipei (China); Lin, Yung-Kai; Chang, Yen; Wang, Chung-Chi; Hsieh, Shih-Rong; Wei, Hao-Ji; Tsai, Hung-Wen [Taichung Veterans General Hospital, Section of Cardiovascular Surgery, Cardiovascular Center, Taichung (China); Fu, Yun-Ching; Jan, Sheng-Ling [Institute of Clinical Medicine and Faculty of Medicine, National Yang-Ming University, Taipei (China); Taichung Veterans General Hospital, Section of Pediatric Cardiology, Department of Pediatrics, Taichung (China); Wang, Kuo-Yang [Taichung Veterans General Hospital, Section of General Cardiology, Cardiovascular Center, Taichung (China); Chung-Shan Medical University, Department of Medicine, Taichung (China); Chen, Min-Chi; Chen, Clayton Chi-Chang [Taichung Veterans General Hospital, Department of Radiology, Taichung (China); Central Taiwan University of Science and Technology, Department of Radiological Technology, Taichung (China)

    2009-04-15

    The purpose was to compare the findings of multi-detector computed tomography (MDCT) in prosthetic valve disorders using the operative findings as a gold standard. In a 3-year period, we prospectively enrolled 25 patients with 31 prosthetic heart valves. MDCT and transthoracic echocardiography (TTE) were done to evaluate pannus formation, prosthetic valve dysfunction, suture loosening (paravalvular leak) and pseudoaneurysm formation. Patients indicated for surgery received an operation within 1 week. The MDCT findings were compared with the operative findings. One patient with a Bjoerk-Shiley valve could not be evaluated by MDCT due to a severe beam-hardening artifact; thus, the exclusion rate for MDCT was 3.2% (1/31). Prosthetic valve disorders were suspected in 12 patients by either MDCT or TTE. Six patients received an operation that included three redo aortic valve replacements, two redo mitral replacements and one Amplatzer ductal occluder occlusion of a mitral paravalvular leak. The concordance of MDCT for diagnosing and localizing prosthetic valve disorders and the surgical findings was 100%. Except for images impaired by severe beam-hardening artifacts, MDCT provides excellent delineation of prosthetic valve disorders. (orig.)

  17. Lumbar disc excision through fenestration

    Directory of Open Access Journals (Sweden)

    Sangwan S

    2006-01-01

    Full Text Available Background : Lumbar disc herniation often causes sciatica. Many different techniques have been advocated with the aim of least possible damage to other structures while dealing with prolapsed disc surgically in the properly selected and indicated cases. Methods : Twenty six patients with clinical symptoms and signs of prolapsed lumbar intervertebral disc having radiological correlation by MRI study were subjected to disc excision by interlaminar fenestration method. Results : The assessment at follow-up showed excellent results in 17 patients, good in 6 patients, fair in 2 patients and poor in 1 patient. The mean preoperative and postoperative Visual Analogue Scores were 9.34 ±0.84 and 2.19 ±0.84 on scale of 0-10 respectively. These were statistically significant (p value< 0.001, paired t test. No significant complications were recorded. Conclusion : Procedures of interlaminar fenestration and open disc excision under direct vision offers sufficient adequate exposure for lumbar disc excision with a smaller incision, lesser morbidity, shorter convalescence, early return to work and comparable overall results in the centers where recent laser and endoscopy facilities are not available.

  18. The activL® Artificial Disc: a next-generation motion-preserving implant for chronic lumbar discogenic pain

    Directory of Open Access Journals (Sweden)

    Yue JJ

    2016-05-01

    Full Text Available James J Yue,1 Rolando Garcia Jr,2 Larry E Miller3 1Department of Orthopaedic Surgery, Yale School of Medicine, New Haven, CT, 2Orthopedic Care Center, Miami, FL, 3Miller Scientific Consulting, Inc., Asheville, NC, USA Abstract: Degeneration of the lumbar intervertebral discs is a leading cause of chronic low back pain in adults. Treatment options for patients with chronic lumbar discogenic pain unresponsive to conservative management include total disc replacement (TDR or lumbar fusion. Until recently, only two lumbar TDRs had been approved by the US Food and Drug Administration - the Charité Artificial Disc in 2004 and the ProDisc-L Total Disc Replacement in 2006. In June 2015, a next-generation lumbar TDR received Food and Drug Administration approval - the activL® Artificial Disc (Aesculap Implant Systems. Compared to previous-generation lumbar TDRs, the activL® Artificial Disc incorporates specific design enhancements that result in a more precise anatomical match and allow a range of motion that better mimics the healthy spine. The results of mechanical and clinical studies demonstrate that the activL® Artificial Disc results in improved mechanical and clinical outcomes versus earlier-generation artificial discs and compares favorably to lumbar fusion. The purpose of this report is to describe the activL® Artificial Disc including implant characteristics, intended use, surgical technique, postoperative care, mechanical testing, and clinical experience to date. Keywords: activL® Artificial Disc, artificial disc, degenerative disc disease, discogenic, implant, lumbar, motion preservation, pain

  19. Comparison of Animal Discs Used in Disc Research to Human Lumbar Disc: Torsion Mechanics and Collagen Content

    Science.gov (United States)

    Showalter, Brent L.; Beckstein, Jesse C.; Martin, John T.; Beattie, Elizabeth E.; Orías, Alejandro A. Espinoza; Schaer, Thomas P.; Vresilovic, Edward J.; Elliott, Dawn M.

    2012-01-01

    Study Design Experimental measurement and normalization of in vitro disc torsion mechanics and collagen content for several animal species used in intervertebral disc research and comparing these to the human disc. Objective To aid in the selection of appropriate animal models for disc research by measuring torsional mechanical properties and collagen content. Summary of Background Data There is lack of data and variability in testing protocols for comparing animal and human disc torsion mechanics and collagen content. Methods Intervertebral disc torsion mechanics were measured and normalized by disc height and polar moment of inertia for 11 disc types in 8 mammalian species: the calf, pig, baboon, goat, sheep, rabbit, rat, and mouse lumbar, and cow, rat, and mouse caudal. Collagen content was measured and normalized by dry weight for the same discs except the rat and mouse. Collagen fiber stretch in torsion was calculated using an analytical model. Results Measured torsion parameters varied by several orders of magnitude across the different species. After geometric normalization, only the sheep and pig discs were statistically different from human. Fiber stretch was found to be highly dependent on the assumed initial fiber angle. The collagen content of the discs was similar, especially in the outer annulus where only the calf and goat discs were statistically different from human. Disc collagen content did not correlate with torsion mechanics. Conclusion Disc torsion mechanics are comparable to human lumbar discs in 9 of 11 disc types after normalization by geometry. The normalized torsion mechanics and collagen content of the multiple animal discs presented is useful for selecting and interpreting results for animal models of the disc. Structural composition of the disc, such as initial fiber angle, may explain the differences that were noted between species after geometric normalization. PMID:22333953

  20. Tactile Sensing Reflexes for Advanced Prosthetic Hands

    Science.gov (United States)

    2016-10-01

    Jeremy A. Fishel, Member, IEEE Figure 1. A) Custom NumaTac prosthetic fingertip sensor core and foam; B) Ottobock VariPlus Speed hand installed with two...oal – H ardw are P rototype D evelopm ent R   Identify alternatives for outcom e m easures R   E xplore sensor design param eters C Y16 G oals – C

  1. Successful Thrombolysis of Aortic Prosthetic Valve Thrombosis ...

    African Journals Online (AJOL)

    Arun Kumar Agnihotri

    patients with valvular heart disease). Endorsed by the Society of Cardiovascular. Anesthesiologists, Society for Cardiovascular. Angiography and Interventions, and Society of. Thoracic Surgeons. J Am Coll Cardiol. 2008;52(13):e1-142. 5. Elkayam U, Bitar F. Valvular heart disease and pregnancy. Part II: prosthetic valves.

  2. Multimodality Imaging Assessment of Prosthetic Heart Valves

    NARCIS (Netherlands)

    Suchá, D.; Symersky, Petr; Tanis, W; Mali, Willem P Th M; Leiner, Tim; van Herwerden, LA; Budde, Ricardo P J

    Echocardiography and fluoroscopy are the main techniques for prosthetic heart valve (PHV) evaluation, but because of specific limitations they may not identify the morphological substrate or the extent of PHV pathology. Cardiac computed tomography (CT) and magnetic resonance imaging (MRI) have

  3. The Prosthetic Experience Between Body and Technology

    DEFF Research Database (Denmark)

    Søndergaard, Morten

    2018-01-01

    In this paper, I argue that a prosthetic aesthetic instigated by experimental art practices operate with and within a ‘second nature’ – in-between science and art. Drawing on theories from Dewey and Edelman and examples from Da Vinci, Brancusi, Man Ray, Dali and Stelarc, I am calling...

  4. Consumer satisfaction in prosthetics and orthotics facilities

    NARCIS (Netherlands)

    Geertzen, J.H.B.; Gankema, H.G.J.; Groothoff, J.W.; Dijkstra, P.U.

    The aim of this study was to assess consumer/patient satisfaction with the services of the prosthetics and orthotics (P&O) facilities in the north of the Netherlands, using a modified SERVQUAL questionnaire. In this questionnaire, consumer interests and experiences are assessed on a 5-point Likert

  5. The relevance of aortic endograft prosthetic infection

    NARCIS (Netherlands)

    Cernohorsky, Paul; Reijnen, Michel M. P. J.; Tielliu, Ignace F. J.; van Sterkenburg, Steven M. M.; van den Dungen, Jan J. A. M.; Zeebregts, Clark J.

    Background: Vascular prosthetic graft infection is a severe complication after open aortic aneurysm repair. Reports of infected endografts are scarce. General treatment consensus with infected graft material is that it should be removed completely. The objective of this study was to describe the

  6. Biomechanics of a Fixed–Center of Rotation Cervical Intervertebral Disc Prosthesis

    Science.gov (United States)

    Crawford, Neil R.; Baek, Seungwon; Sawa, Anna G.U.; Safavi-Abbasi, Sam; Sonntag, Volker K.H.; Duggal, Neil

    2012-01-01

    Background Past in vitro experiments studying artificial discs have focused on range of motion. It is also important to understand how artificial discs affect other biomechanical parameters, especially alterations to kinematics. The purpose of this in vitro investigation was to quantify how disc replacement with a ball-and-socket disc arthroplasty device (ProDisc-C; Synthes, West Chester, Pennsylvania) alters biomechanics of the spine relative to the normal condition (positive control) and simulated fusion (negative control). Methods Specimens were tested in multiple planes by use of pure moments under load control and again in displacement control during flexion-extension with a constant 70-N compressive follower load. Optical markers measured 3-dimensional vertebral motion, and a strain gauge array measured C4-5 facet loads. Results Range of motion and lax zone after disc replacement were not significantly different from normal values except during lateral bending, whereas plating significantly reduced motion in all loading modes (P biomechanics were less substantial after artificial disc placement than after anterior plating. PMID:25694869

  7. Evolution of viscous discs. 3. Giant discs in symbiotic stars

    Energy Technology Data Exchange (ETDEWEB)

    Bath, G T [Oxford Univ. (UK). Dept. of Astrophysics; Pringle, J E [Cambridge Univ. (UK). Inst. of Astronomy

    1982-10-01

    The structure of time-dependent accretion discs in giant binaries with separation of the order of 10/sup 13/ cm is examined. Radiative ..cap alpha..-viscosity discs with ..cap alpha.. of order unity accreting on to main-sequence stars at accretion rates which generate luminosities greater than a giant companion decay on time-scales of the same order as the binary period, unlike those in dwarf nova binaries which decay on time-scales 100 times longer than the binary period. This results from the lower gravitational potential and consequent larger disc thickness (relative to the radius) of luminous 'giant' discs accreting at high accretion rates. The eruptions of the symbiotic binary C I Cygni are modelled by an ..cap alpha.. = 1 disc with outer radius 8.5 x 10/sup 12/ cm and a sequence of five mass-transfer bursts at rates between 1.5 x 10/sup 21/ and 4 x 10/sup 22/g s/sup -1/.

  8. Acinetobacter Prosthetic Joint Infection Treated with Debridement and High-Dose Tigecycline.

    Science.gov (United States)

    Vila, Andrea; Pagella, Hugo; Amadio, Claudio; Leiva, Alejandro

    2016-12-01

    Prosthesis retention is not recommended for multidrug-resistant Acinetobacter prosthetic joint infection due to its high failure rate. Nevertheless, replacing the prosthesis implies high morbidity and prolonged hospitalization. Although tigecycline is not approved for the treatment of prosthetic joint infection due to multidrug resistant Acinetobacter baumannii, its appropriate use may preclude prosthesis exchange. Since the area under the curve divided by the minimum inhibitory concentration is the best pharmacodynamic predictor of its efficacy, we used tigecycline at high dose, in order to optimize its efficacy and achieve implant retention in 3 patients who refused prosthesis exchange. All patients with prosthetic joint infections treated at our Institution are prospectively registered in a database. Three patients with early prosthetic joint infection of total hip arthroplasty due to multidrug resistant A. baumannii were treated with debridement, antibiotics and implant retention, using a high maintenance dose of tigecycline (100 mg every 12 hours). The cases were retrospectively reviewed. All patients signed informed consent for receiving off-label use of tigecycline. Tigecycline was well tolerated, allowing its administration at high maintenance dose for a median of 40 days (range 30-60). Two patients were then switched to minocycline at standard doses for a median of 3.3 months in order to complete treatment. Currently, none of the patients showed relapse. Increasing the dose of tigecycline could be considered as a means to better attain pharmacodynamic targets in patients with severe or difficult-to-treat infections. Tigecycline at high maintenance dose might be useful when retention of the implant is attempted for treatment for prosthetic joint infections due to multidrug resistant Acinetobacter. Although this approach might be promising, off-label use of tigecycline should be interpreted cautiously until prospective data are available. Tigecycline is

  9. Oral health-related quality of life and prosthetic status of nursing home residents with or without dementia.

    Science.gov (United States)

    Klotz, Anna-Luisa; Hassel, Alexander Jochen; Schröder, Johannes; Rammelsberg, Peter; Zenthöfer, Andreas

    2017-01-01

    The objective of this cross-sectional study was to evaluate the effect of prosthetic status on the oral health-related quality of life (OHRQoL) of nursing home residents with or without dementia. The study was performed in 14 nursing homes across the federal state of Baden-Württemberg, Germany. All eligible participants were included, and general and medical information and information about their dental and prosthetic statuses were collected. The Geriatric Oral Health Assessment Index (GOHAI) was administered to evaluate OHRQoL. The Mini-Mental State Examination (MMSE) served to classify participants into living or not living with dementia according to the established cutoff value for dementia (MMSE health was also similar in both groups ( P >0.05). The number of teeth (odds ratio [OR]: 2.0), the type of prosthetic status (OR: 6.5), and denture-related treatment needs (OR: 2.4) were the major factors significantly affecting OHRQoL ( P nursing home residents is substantially compromised. Several prosthetic treatment needs for residents living with or without dementia were identified. Edentulism without tooth replacement and having <5 teeth resulted in an increased risk of substantially compromised OHRQoL. Further studies should be conducted to determine whether improvements in prosthetic status can increase OHRQoL.

  10. Prosthetic valve endocarditis 7 months after transcatheter aortic valve implantation diagnosed with 3D TEE

    Directory of Open Access Journals (Sweden)

    Cenk Sarı

    2016-03-01

    Full Text Available Transcatheter aortic valve implantation (TAVI was introduced as an alternative treatment for patients with severe symptomatic aortic stenosis for whom surgery would be high-risk. Prosthetic aortic valve endocarditis is a serious complication of surgical AVR (SAVR with high morbidity and mortality. According to recent cases, post-TAVI prosthetic valve endocarditis (PVE seems to occur very rarely. We present the case of a 75-year-old woman who underwent TAVI (Edwards Saphien XT with an uneventful postoperative stay. She was diagnosed with endocarditis using three dimensional (3D echocardiography on the TAVI device 7 months later and she subsequently underwent surgical aortic valve replacement. Little experience of the interpretation of transoesophageal echocardiography (TEE and the clinical course and effectiveness of treatment strategies in post-TAVI endocarditis exists. We report a case of PVE in a TAVI patient which was diagnosed with three-dimensional transoesophageal echocardiography (3DTEE.

  11. [Self-assembly tissue engineering fibrocartilage model of goat temporomandibular joint disc].

    Science.gov (United States)

    Kang, Hong; Li, Zhen-Qiang; Bi, Yan-Da

    2011-06-01

    To construct self-assembly fibrocartilage model of goat temporomandibular joint disc and observe the biological characteristics of the self-assembled fibrocartilage constructs, further to provide a basis for tissue engineering of the temporomandibular joint disc and other fibrocartilage. Cells from temporomandibular joint discs of goats were harvested and cultured. 5.5 x 10(6) cells were seeded in each agarose well with diameter 5 mm x depth 10 mm, daily replace of medium, cultured for 2 weeks. One day after seeding, goat temporomandibular joint disc cells in agarose wells were gathered and began to self-assemble into a disc-shaped base, then gradually turned into a round shape. When cultured for 2 weeks, hematoxylin-eosin staining was conducted and observed that cells were round and wrapped around by the matrix. Positive Safranin-O/fast green staining for glycosaminoglycans was observed throughout the entire constructs, and picro-sirius red staining was examined and distribution of numerous type I collagen was found. Immunohistochemistry staining demonstrated brown yellow particles in cytoplasm and around extracellular matrix, which showed self-assembly construct can produce type I collagen as native temporomandibular joint disc tissue. Production of extracellular matrix in self-assembly construct as native temporomandibular joint disc tissue indicates that the use of agarose wells to construct engineered temporomandibular joint disc will be possible and practicable.

  12. Impact of pannus formation on hemodynamic dysfunction of prosthetic aortic valve: pannus extent and its relationship to prosthetic valve motion and degree of stenosis.

    Science.gov (United States)

    Koo, Hyun Jung; Ha, Hojin; Kang, Joon-Won; Kim, Jeong A; Song, Jae-Kwan; Kim, Hwa Jung; Lim, Tae-Hwan; Yang, Dong Hyun

    2018-02-19

    Although pannus is an important cause of prosthetic valve dysfunction, the minimum pannus size that can induce hemodynamic dysfunction has not yet been determined. This study investigated the correlation between the limitation of motion (LOM) of the prosthetic valve and pannus extent and determined the pannus extent that could induce severe aortic stenosis. This study included 49 patients who underwent mechanical aortic valve replacement (AVR) and showed pannus on cardiac computed tomography (CT). Pannus width, ratio of pannus width to valve diameter, pannus area, effective orifice area, encroachment ratio by pannus, pannus involvement angle and percent LOM of mechanical valves were evaluated on CT. Transvalvular peak velocity (TPV) and transvalvular pressure gradient (TPG) were measured by transesophageal echocardiography to determine the degree of aortic stenosis. The relationship between percent LOM of the prosthetic valve and pannus extent and the cut-off of pannus extent required to induce severe aortic stenosis were evaluated. The mean interval between AVR and pannus formation was 11 years and was longer in patients with than without severe aortic stenosis (14.0 vs. 7.3 years). On CT, the percent LOM of the prosthetic valve was significantly associated with the extent of pannus only in patients with pannus involvement angle > 180° (r = 0.55-0.68, P Pannus width, effective orifice area, and encroachment ratio were significantly associated with increased TPV and TPG (r = 0.51-0.62, P Pannus width > 3.5 mm, pannus width/valve inner diameter > 0.15, and encroachment ratio > 0.14 were significantly associated with severe aortic stenosis (TPV > 4 m/s; mean TPG ≥ 35 mmHg), with c-indices of 0.74-079 (P pannus extent parameters are good indicators of significant hemodynamic changes with increased TPV and mean TPG.

  13. Replacement rod

    International Nuclear Information System (INIS)

    Hatfield, S.C.

    1989-01-01

    This patent describes in an elongated replacement rod for use with fuel assemblies of the type having two end fittings connected by guide tubes with a plurality of rod and guide tube cell defining spacer grids containing rod support features and mixing vanes. The grids secured to the guide tubes in register between the end fittings at spaced intervals. The fuel rod comprising: an asymmetrically beveled tip; a shank portion having a straight centerline; and a permanently diverging portion between the tip and the shank portion

  14. Intervertebral disc (IVD): Structure, degeneration, repair and regeneration

    Energy Technology Data Exchange (ETDEWEB)

    Whatley, Benjamin R.; Wen Xuejun, E-mail: xjwen@clemson.edu

    2012-02-01

    Low back pain affects a large portion of the population, resulting in high care costs for therapy and treatment. One primary cause of low back pain is the degeneration of the intervertebral disc (IVD) resulting in the compression of the spinal nerves and adjacent vertebrae. Exact causes of degeneration are unknown, but it is thought that natural aging, and both biological and genetic factors may play a significant role in the degenerative process. Conventional methods to alleviate low back pain include spinal fusion and artificial disc replacement. Traditional treatments through spinal fusion may eliminate pain yet do not restore disc function and lead to further degeneration of adjacent levels by altering disc biomechanics and natural kinematics. Recently, artificial IVD replacements have started to gain interest, with two IVD implants currently approved in the United States. Although these implants facilitate the preservation of motions and disc space height, they are unable to sustain compressive forces due to their lack of elasticity. In addition, the implants may produce wear debris that can cause osteolysis and other deleterious effects. As an alternative to these conventional approaches, tissue engineered IVD constructs offer the advantage of biointegration while preserving the essential attributes of natural motion and disc space restoration. There is a great need for the development of tissue engineered scaffolds that simulate the natural 3D morphology and microenvironment of the targeted tissue. Scaffolds should facilitate biological transport to satisfy nutrition and waste removal requirements within the IVD. The discrete tissue architectures of the nucleus pulposus (NP) and annulus fibrosus (AF) have posed great challenges to IVD tissue engineering. Current attempts have not been able to satisfy the biological functions and/or mechanical properties of native tissue. Therefore, these current scaffolds are far from satisfactory. This review highlights the

  15. Complementary role of cardiac CT in the assessment of aortic valve replacement dysfunction

    Science.gov (United States)

    Moss, Alastair J; Dweck, Marc R; Dreisbach, John G; Williams, Michelle C; Mak, Sze Mun; Cartlidge, Timothy; Nicol, Edward D; Morgan-Hughes, Gareth J

    2016-01-01

    Aortic valve replacement is the second most common cardiothoracic procedure in the UK. With an ageing population, there are an increasing number of patients with prosthetic valves that require follow-up. Imaging of prosthetic valves is challenging with conventional echocardiographic techniques making early detection of valve dysfunction or complications difficult. CT has recently emerged as a complementary approach offering excellent spatial resolution and the ability to identify a range of aortic valve replacement complications including structural valve dysfunction, thrombus development, pannus formation and prosthetic valve infective endocarditis. This review discusses each and how CT might be incorporated into a multimodal cardiovascular imaging pathway for the assessment of aortic valve replacements and in guiding clinical management. PMID:27843568

  16. Vertebral osteomyelitis without disc involvement

    Energy Technology Data Exchange (ETDEWEB)

    Kamani, I.; Syed, I.; Saifuddin, A. E-mail: asaifuddin@aol.com; Green, R.; MacSweeney, F

    2004-10-01

    Vertebral osteomyelitis is most commonly due to pyogenic or granulomatous infection and typically results in the combined involvement of the intervertebral disc and adjacent vertebral bodies. Non-infective causes include the related conditions of chronic recurrent multifocal osteomyelitis (CRMO) and SAPHO (synovitis, acne, pustulosis, hyperostosis, and osteitis) syndrome. Occasionally, these conditions may present purely within the vertebral body, resulting in various combinations of vertebral marrow oedema and sclerosis, destructive lesions of the vertebral body and pathological vertebral collapse, thus mimicking neoplastic disease. This review illustrates the imaging features of vertebral osteomyelitis without disc involvement, with emphasis on magnetic resonance imaging (MRI) findings.

  17. Cervical artificial disc extrusion after a paragliding accident.

    Science.gov (United States)

    Niu, Tianyi; Hoffman, Haydn; Lu, Daniel C

    2017-01-01

    Cervical total disc replacement (TDR) is an established alternative to anterior cervical discectomy and fusion (ACDF) with excellent long-term outcomes and low failure rates. Cases of implant failure and migration are scarce and primarily limited to several years postoperatively. The authors report a case of anterior extrusion of a C4-C5 ProDisc-C (DePuy Synthes, West Chester, PA, USA) cervical artificial disc (CAD) 14 months after placement due to minor trauma. A 33-year-old female who had undergone C4-C5 CAD implantation presented with neck pain and spasm after experiencing a paragliding accident. A 4 mm anterior protrusion of the CAD was seen on x-ray. She underwent removal of the CAD followed by anterior fusion. Other cases of CAD extrusion in the literature are discussed and the device's durability and testing are considered. Overall, CAD extrusion is a rare event. This case is likely the result of insufficient osseous integration. Patients undergoing cervical TDR should avoid high-risk activities to prevent trauma that could compromise the disc's placement, and future design/research should focus on how to enhance osseous integration at the interface while minimizing excessive heterotopic ossification.

  18. Mitral Prosthetic Valve Obstruction and Its Complications

    Directory of Open Access Journals (Sweden)

    Rajesh Rajan

    2015-12-01

    Full Text Available Prosthetic Valve Obstruction (PVO is a serious complication which is associated with increased morbidity and mortality. This could result from thrombus formation, development of pannus, or a combination of both. Patients with this complication often present with symptoms and signs of heart failure, systemic embolism, acute cardiovascular collapse, and sudden death. Transesophageal echocardiography and cine fluoroscopy play a vital role in diagnosis of this potentially lethal condition. Herein, we reported a 56-year-old male patient who presented with severe heart failure and was found to have obstructed ATS27 bileaflet mitral prosthetic valve. Thrombolysis and redo surgery are two important options for treating this condition although guidelines for choosing between the two are not very definite.

  19. Prosthetic valve obstruction: Redo surgery or fibrinolysis?

    Directory of Open Access Journals (Sweden)

    Avinash Inamdar

    2017-01-01

    Full Text Available Objective: The aim of this study was to compare the efficacy and safety of surgery versus fibrinolytic therapy in patients with prosthetic valve obstruction. Materials and Methods: We compared 15 patients of prosthetic valve thrombosis treated by surgical line of management and another 15 patients treated by thrombolysis. All patients were initially assessed by clinical evaluation and diagnosis confirmed by transthoracic and transesophageal two-dimensional echocardiography. Depending on hemodynamic stability, pannus, or thrombus on transesophageal echocardiography, the patients were assigned surgical or medical line of management. Results: Patients mortality rate was 40% in fibrinolytic group and 13.33% in surgical group. Recurrence was 40% in fibrinolytic group while there was no recurrence till date in surgery group. Complications were more in fibrinolytic group as opposed to surgery group patient. Conclusion: From our experience, we conclude that redo surgery is effective and definitive treatment, especially in patients with stable hemodynamic conditions.

  20. Prosthetic vascular graft infection and prosthetic joint infection caused by Pseudomonas stutzeri.

    Science.gov (United States)

    Bonares, Michael J; Vaisman, Alon; Sharkawy, Abdu

    2016-01-01

    Pseudomonas stutzeri is infrequently isolated from clinical specimens, and if isolated, more likely represents colonization or contamination rather than infection. Despite this, there are dozens of case reports which describe clinically significant P. stutzeri infections at variable sites. A 69-year-old man had a P. stutzeri infection of a prosthetic vascular graft infection, which he received in Panama City. He was successfully treated with a single antipseudomonal agent for 6 weeks and the removal of the infected vascular graft. A 70-year-old man had a P. stutzeri infection of a prosthetic joint, which was successfully treated with a single anti-pseudomonal agent for 6 weeks. There is only one other documented case of a prosthetic vascular graft infection secondary to P. stutzeri . There are 5 documented cases of P. stutzeri prosthetic joint infections. The previous cases were treated with antibiotics and variably, source control with the removal of prosthetic material. Most cases of P. stutzeri infection are due to exposure in health care settings. Immunocompromised states such as HIV or hematological and solid tumor malignancies are risk factors for P. stutzeri infection. Infections caused by P. stutzeri are far less frequent and less fatal than those caused by P. aeruginosa. The etiology of a P. stutzeri infection could be exposure to soil and water, but also contaminated material in the health care setting or an immunocompromised state. Iatrogenic infections that are secondary to health care tourism are a potential cause of fever in the returned traveler.

  1. Prosthetic management of an ocular defect

    Directory of Open Access Journals (Sweden)

    Siddesh Kumar Chintal

    2010-01-01

    Full Text Available The disfigurement associated with the loss of an eye can cause significant physical and emotional problems. Various treatment modalities are available, one of which is implants. Although implant has a superior outcome, it may not be advisable in all patients due to economic factors. The present article describes the prosthetic management of an ocular defect with a custom-made ocular prosthesis.

  2. New developments in prosthetic arm systems

    Directory of Open Access Journals (Sweden)

    Vujaklija I

    2016-07-01

    Full Text Available Ivan Vujaklija,1 Dario Farina,1 Oskar C Aszmann2 1Institute of Neurorehabilitation Systems, Bernstein Focus Neurotechnology Göttingen, University Medical Center Göttingen, Georg-August University, Göttingen, Germany; 2Christian Doppler Laboratory for Restoration of Extremity Function, Division of Plastic and Reconstructive Surgery, Department of Surgery, Medical University of Vienna, Vienna, Austria Abstract: Absence of an upper limb leads to severe impairments in everyday life, which can further influence the social and mental state. For these reasons, early developments in cosmetic and body-driven prostheses date some centuries ago, and they have been evolving ever since. Following the end of the Second World War, rapid developments in technology resulted in powered myoelectric hand prosthetics. In the years to come, these devices were common on the market, though they still suffered high user abandonment rates. The reasons for rejection were trifold – insufficient functionality of the hardware, fragile design, and cumbersome control. In the last decade, both academia and industry have reached major improvements concerning technical features of upper limb prosthetics and methods for their interfacing and control. Advanced robotic hands are offered by several vendors and research groups, with a variety of active and passive wrist options that can be articulated across several degrees of freedom. Nowadays, elbow joint designs include active solutions with different weight and power options. Control features are getting progressively more sophisticated, offering options for multiple sensor integration and multi-joint articulation. Latest developments in socket designs are capable of facilitating implantable and multiple surface electromyography sensors in both traditional and osseointegration-based systems. Novel surgical techniques in combination with modern, sophisticated hardware are enabling restoration of dexterous upper limb

  3. Control system and method for prosthetic devices

    Science.gov (United States)

    Bozeman, Richard J., Jr. (Inventor)

    1992-01-01

    A control system and method for prosthetic devices is provided. The control system comprises a transducer for receiving movement from a body part for generating a sensing signal associated with that movement. The sensing signal is processed by a linearizer for linearizing the sensing signal to be a linear function of the magnitude of the distance moved by the body part. The linearized sensing signal is normalized to be a function of the entire range of body part movement from the no-shrug position of the movable body part through the full-shrug position of the movable body part. The normalized signal is divided into a plurality of discrete command signals. The discrete command signals are used by typical converter devices which are in operational association with the prosthetic device. The converter device uses the discrete command signals for driving the movable portions of the prosthetic device and its sub-prosthesis. The method for controlling a prosthetic device associated with the present invention comprises the steps of receiving the movement from the body part, generating a sensing signal in association with the movement of the body part, linearizing the sensing signal to be a linear function of the magnitude of the distance moved by the body part, normalizing the linear signal to be a function of the entire range of the body part movement, dividing the normalized signal into a plurality of discrete command signals, and implementing the plurality of discrete command signals for driving the respective movable prosthesis device and its sub-prosthesis.

  4. Smart Prosthetic Hand Technology - Phase 2

    Science.gov (United States)

    2011-05-01

    functional magnetic resonance imaging (f- MRI ) was used to analyze the reciprocal adaptation between the human brain and the prosthetic hand by the...Schmidt PC. Influence of compacted hydrophobic and hydrophilic colloidal silicon dioxide on tableting properties of pharmaceutical excipients. Drug Dev...nanoparticles, and manganese nanoparticles) in magnetic resonance imaging ( MRI ) in the detection and staging of cancer [2]. 2.1 Iron Oxide

  5. Dynamic elasticity measurement for prosthetic socket design.

    Science.gov (United States)

    Kim, Yujin; Kim, Junghoon; Son, Hyeryon; Choi, Youngjin

    2017-07-01

    The paper proposes a novel apparatus to measure the dynamic elasticity of human limb in order to help the design and fabrication of the personalized prosthetic socket. To take measurements of the dynamic elasticity, the desired force generated as an exponential chirp signal in which the frequency increases and amplitude is maintained according to time progress is applied to human limb and then the skin deformation is recorded, ultimately, to obtain the frequency response of its elasticity. It is referred to as a Dynamic Elasticity Measurement Apparatus (DEMA) in the paper. It has three core components such as linear motor to provide the desired force, loadcell to implement the force feedback control, and potentiometer to record the skin deformation. After measuring the force/deformation and calculating the dynamic elasticity of the limb, it is visualized as 3D color map model of the limb so that the entire dynamic elasticity can be shown at a glance according to the locations and frequencies. For the visualization, the dynamic elasticities measured at specific locations and frequencies are embodied using the color map into 3D limb model acquired by using 3D scanner. To demonstrate the effectiveness, the visualized dynamic elasticities are suggested as outcome of the proposed system, although we do not have any opportunity to apply the proposed system to the amputees. Ultimately, it is expected that the proposed system can be utilized to design and fabricate the personalized prosthetic socket in order for releasing the wearing pain caused by the conventional prosthetic socket.

  6. Adaptive sports technology and biomechanics: prosthetics.

    Science.gov (United States)

    De Luigi, Arthur Jason; Cooper, Rory A

    2014-08-01

    With the technologic advances in medicine and an emphasis on maintaining physical fitness, the population of athletes with impairments is growing. It is incumbent upon health care practitioners to make every effort to inform these individuals of growing and diverse opportunities and to encourage safe exercise and athletic participation through counseling and education. Given the opportunities for participation in sports for persons with a limb deficiency, the demand for new, innovative prosthetic designs is challenging the clinical and technical expertise of the physician and prosthetist. When generating a prosthetic prescription, physicians and prosthetists should consider the needs and preferences of the athlete with limb deficiency, as well as the functional demands of the chosen sporting activity. The intent of this article is to provide information regarding the current advancements in the adaptive sports technology and biomechanics in the field of prosthetics, and to assist clinicians and their patients in facilitating participation in sporting activities. Copyright © 2014 American Academy of Physical Medicine and Rehabilitation. Published by Elsevier Inc. All rights reserved.

  7. Wear analysis of disc cutters of full face rock tunnel boring machine

    Science.gov (United States)

    Zhang, Zhaohuang; Meng, Liang; Sun, Fei

    2014-11-01

    Wear is a major factor of disc cutters' failure. No current theory offers a standard for the prediction of disc cutter wear yet. In the field the wear prediction method commonly used is based on the excavation length of tunnel boring machine(TBM) to predict the disc cutter wear and its wear law, considering the location number of each disc cutter on the cutterhead(radius for installation); in theory, there is a prediction method of using arc wear coefficient. However, the preceding two methods have their own errors, with their accuracy being 40% or so and largely relying on the technicians' experience. Therefore, radial wear coefficient, axial wear coefficient and trajectory wear coefficient are defined on the basis of the operating characteristics of TBM. With reference to the installation and characteristics of disc cutters, those coefficients are modified according to penetration, which gives rise to the presentation of comprehensive axial wear coefficient, comprehensive radial wear coefficient and comprehensive trajectory wear coefficient. Calculation and determination of wear coefficients are made with consideration of data from a segment of TBM project(excavation length 173 m). The resulting wear coefficient values, after modification, are adopted to predict the disc cutter wear in the follow-up segment of the TBM project(excavation length of 5621 m). The prediction results show that the disc cutter wear predicted with comprehensive radial wear coefficient and comprehensive trajectory wear coefficient are not only accurate(accuracy 16.12%) but also highly congruous, whereas there is a larger deviation in the prediction with comprehensive axial wear coefficient(accuracy 41%, which is in agreement with the prediction of disc cutters' life in the field). This paper puts forth a new method concerning prediction of life span and wear of TBM disc cutters as well as timing for replacing disc cutters.

  8. Intervertebral disc degeneration in dogs

    NARCIS (Netherlands)

    Bergknut, N.

    2011-01-01

    Back pain is common in both dogs and humans, and is often associated with intervertebral disc (IVD) degeneration. The IVDs are essential structures of the spine and degeneration can ultimately result in diseases such as IVD herniation or spinal instability. In order to design new treatments halting

  9. Intervertebral disc degeneration in dogs

    NARCIS (Netherlands)

    Bergknut, Niklas

    Back pain is common in both dogs and humans, and is often associated with intervertebral disc (IVD) degeneration. The IVDs are essential structures of the spine and degeneration can ultimately result in diseases such as IVD herniation or spinal instability. In order to design new treatments halting

  10. CT morphometry of adult thoracic intervertebral discs.

    Science.gov (United States)

    Fletcher, Justin G R; Stringer, Mark D; Briggs, Christopher A; Davies, Tilman M; Woodley, Stephanie J

    2015-10-01

    Despite being commonly affected by degenerative disorders, there are few data on normal thoracic intervertebral disc dimensions. A morphometric analysis of adult thoracic intervertebral discs was, therefore, undertaken. Archival computed tomography scans of 128 recently deceased individuals (70 males, 58 females, 20-79 years) with no known spinal pathology were analysed to determine thoracic disc morphometry and variations with disc level, sex and age. Reliability was assessed by intraclass correlation coefficients (ICCs). Anterior and posterior intervertebral disc heights and axial dimensions were significantly greater in men (anterior disc height 4.0±1.4 vs 3.6±1.3 mm; posterior disc height 3.6±0.90 vs 3.4±0.93 mm; p<0.01). Disc heights and axial dimensions at T4-5 were similar or smaller than at T2-3, but thereafter increased caudally (mean anterior disc height T4-5 and T10-11, 2.7±0.7 and 5.4±1.2 mm, respectively, in men; 2.6±0.8 and 5.1±1.3 mm, respectively, in women; p<0.05). Except at T2-3, anterior disc height decreased with advancing age and anteroposterior and transverse disc dimensions increased; posterior and middle disc heights and indices of disc shape showed no consistent statistically significant changes. Most parameters showed substantial to almost perfect agreement for intra- and inter-rater reliability. Thoracic disc morphometry varies significantly and consistently with disc level, sex and age. This study provides unique reference data on adult thoracic intervertebral disc morphometry, which may be useful when interpreting pathological changes and for future biomechanical and functional studies.

  11. Stiffness and hysteresis properties of some prosthetic feet

    OpenAIRE

    van Jaarsveld, H.W.L.; Grootenboer, H.J.; de Vries, J.; Koopman, Hubertus F.J.M.

    1990-01-01

    A prosthetic foot is an important element of a prosthesis, although it is not always fully recognized that the properties of the foot, along with the prosthetic knee joint and the socket, are in part responsible for the stability and metabolic energy cost during walking. The stiffness and the hysteresis, which are the topics of this paper, are not properly prescribed, but could be adapted to improve the prosthetic walking performance. The shape is strongly related to the cosmetic appearance a...

  12. Thermochemical modelling of brown dwarf discs

    NARCIS (Netherlands)

    Greenwood, A. J.; Kamp, I.; Waters, L. B. F. M.; Woitke, P.; Thi, W.-F.; Rab, Ch.; Aresu, G.; Spaans, M.

    The physical properties of brown dwarf discs, in terms of their shapes and sizes, are still largely unexplored by observations. ALMA has by far the best capabilities to observe these discs in sub-mm CO lines and dust continuum, while also spatially resolving some discs. To what extent brown dwarf

  13. Fused Filament Fabrication of Prosthetic Components for Trans-Humeral Upper Limb Prosthetics

    Science.gov (United States)

    Lathers, Steven M.

    Presented below is the design and fabrication of prosthetic components consisting of an attachment, tactile sensing, and actuator systems with Fused Filament Fabrication (FFF) technique. The attachment system is a thermoplastic osseointegrated upper limb prosthesis for average adult trans-humeral amputation with mechanical properties greater than upper limb skeletal bone. The prosthetic designed has: a one-step surgical process, large cavities for bone tissue ingrowth, uses a material that has an elastic modulus less than skeletal bone, and can be fabricated on one system. FFF osseointegration screw is an improvement upon the current two-part osseointegrated prosthetics that are composed of a fixture and abutment. The current prosthetic design requires two invasive surgeries for implantation and are made of titanium, which has an elastic modulus greater than bone. An elastic modulus greater than bone causes stress shielding and overtime can cause loosening of the prosthetic. The tactile sensor is a thermoplastic piezo-resistive sensor for daily activities for a prosthetic's feedback system. The tactile sensor is manufactured from a low elastic modulus composite comprising of a compressible thermoplastic elastomer and conductive carbon. Carbon is in graphite form and added in high filler ratios. The printed sensors were compared to sensors that were fabricated in a gravity mold to highlight the difference in FFF sensors to molded sensors. The 3D printed tactile sensor has a thickness and feel similar to human skin, has a simple fabrication technique, can detect forces needed for daily activities, and can be manufactured in to user specific geometries. Lastly, a biomimicking skeletal muscle actuator for prosthetics was developed. The actuator developed is manufactured with Fuse Filament Fabrication using a shape memory polymer composite that has non-linear contractile and passive forces, contractile forces and strains comparable to mammalian skeletal muscle, reaction

  14. CT findings of lumbar intervertebral disc: II. Disc herniation (HNP)

    International Nuclear Information System (INIS)

    Yang, W. J.; Lee, J. M.; Bahk, Y. W.

    1984-01-01

    In lumbar region the epidural fat pad is relatively abundant so that CT can provides sufficient information in diagnosis of lumbar HNP. Many authors have reported on the CT findings of HNP such as focal nodular protrusion of the posterior disc margin, obliteration of epidural fat pad, impingement of dural sac and nerve root, swelling of nerve root, soft tissue density in the spinal canal and calcification of disc. However there was so previous report describing incidence and reliability of the findings. It is the purpose of the present study to survey the frequency, reliability, and limitation of these CT findings. The clinical material was consisted of 30 operatively proven cases of HNP of the lumbar spine. Each lumbar CT scan was reviewed retrospectively and the findings were analysed by two radiologists independently. There were 20 males and 10 females and the mean age was 36.7 years. Involvement of L4-S5 level was 2.3 times more frequent than that of L5-S1 level. Of 30 cases, 22 were unilateral posterolateral types and 8 cases central or unilateral far lateral types. CT findings observed were nodular protrusion of the posterior margin of the disc, obliteration of epidural fat pad, impingement of dural sac or nerve root, soft tissue density in the spinal canal and calcification in the posterior portion of the protruded disc, in order of decreasing frequency. The conclusions are follows: 1. Nodular protrusion of the posterior disc margin accompanied by obliteration of epidural fat pad was observed in every case. The former findings was designated as direct sign and the latter indirect. 2. Obliteration of the epidural fat appears to be significant in lateral recesses especially when it occurs unilaterally. This was not true, however, in the centrally located fat pad. 3. Impingement of the dural sac and nerve root were observed in 90% and 67%, respectively, and were very helpful in establishing HNP diagnosis when the direct and indirect signs were equivocal

  15. Prevention of dental anomalies in children by prosthetics defects hard tooth tissues and dentitions: the need to possibilities

    Directory of Open Access Journals (Sweden)

    Suetenkov D.Ye.

    2011-03-01

    Full Text Available This article presents the possibility of restore the function and anatomy of the tooth and replacement of defects of dentition by prosthesis in children under the removable bite as a method of prevention of dentoalveolar anomalies. Identified the need for prosthetic treatment of children and the willingness of dentists as primary health care professional to address the problems identified. A clinical analysis of complex treatment of defects in the teeth with fixed restorations

  16. Echocardiographic Evaluation of Tricuspid Prosthetic Valves: An Update

    Directory of Open Access Journals (Sweden)

    Dimitrios Maragiannis, MD, FASE, FACC

    2016-05-01

    Full Text Available This review focuses on the diagnostic value of novel echocardiographic techniques and the clinical application of recently described algorithms to assess tricuspid prosthetic valve function.

  17. Prosthetic hip joint infection due to Campylobacter fetus.

    OpenAIRE

    Bates, C J; Clarke, T C; Spencer, R C

    1994-01-01

    A case of postoperative prosthetic hip joint infection due to Campylobacter fetus subsp. fetus is described. Difficulties in isolation and antimicrobial susceptibility testing of this organism are discussed.

  18. Shoulder replacement - discharge

    Science.gov (United States)

    Total shoulder arthroplasty - discharge; Endoprosthetic shoulder replacement - discharge; Partial shoulder replacement - discharge; Partial shoulder arthroplasty - discharge; Replacement - shoulder - discharge; Arthroplasty - shoulder - discharge

  19. Cryopreserved Human Allografts for the Reconstruction of Aortic and Peripheral Prosthetic Graft Infection.

    Science.gov (United States)

    Bossi, Matteo; Tozzi, Matteo; Franchin, Marco; Ferraro, Stefania; Rivolta, Nicola; Ferrario, Massimo; Guttadauro, Chiara; Castelli, Patrizio; Piffaretti, Gabriele

    2017-12-25

    Background : This study aimed to present cases with cryopreserved human allografts (CHAs) for vascular reconstruction in both aortic and peripheral infected prosthetic grafts. Materials and Methods : This is a single center, observational descriptive study with retrospective analysis. In all cases, the infected prosthetic graft material was completely removed. At discharge, patients were administered anticoagulants. Follow-up examinations included clinical visits, echo-color-Doppler ultrasounds, or computed tomography angiography within 30 days and at 3, 6, and 12 months after the treatment, and then twice per year. Results : We treated 21 patients (90% men, n=19) with the mean age of 71±12 years and mean interval between the initial operation and replacement with CHA of 30 months [range, 1-216; interquartile range (IQR), 2-36]. In-hospital mortality was 14% (n=3); no CHA-related complication led to death. Limb salvage was 100%. No patient was lost at the median follow-up of 14 months (range, 2-61; IQR, 6-39). No rupture, aneurysmal degeneration, or re-infection occurred. Estimated freedom from CHA-related adverse events (95% confidence interval, 43-63) was 95% at 3 years. Conclusion : In our experience, CHAs are a viable option for prosthetic graft infections and provide satisfactory clinical results and favorable stability because of a very low rate of CHA-related adverse events during follow-up.

  20. Prosthetic tricuspid valve dysfunction assessed by three-dimensional transthoracic and transesophageal echocardiography.

    Science.gov (United States)

    Yuasa, Toshinori; Takasaki, Kunitsugu; Mizukami, Naoko; Ueya, Nami; Kubota, Kayoko; Horizoe, Yoshihisa; Chaen, Hideto; Kuwahara, Eiji; Kisanuki, Akira; Hamasaki, Shuichi

    2013-09-01

    A 39-year-old male who had undergone tricuspid valve replacement for severe tricuspid regurgitation was admitted with palpitation and general edema. Two-dimensional (2D) echocardiography showed tricuspid prosthetic valve dysfunction. Additional three-dimensional (3D) transthoracic and transesophageal echocardiography (TEE) could clearly demonstrate the disabilities of the mechanical tricuspid valve. Particularly, 3D TEE demonstrated a mass located on the right ventricular side of the tricuspid prosthesis, which may have caused the stuck disk. This observation was confirmed by intra-operative findings.

  1. Wear analysis by applying a pin-disc configuration to phemoral head and acetabular cup

    Directory of Open Access Journals (Sweden)

    Guillermo Urriolagoitia-Calderón

    2008-01-01

    Full Text Available This work determines a prosthetic hip system’s life-span, focusing on a Mexican phenotype. The total sliding equivalent distance for the system was determined, as well as the loading regime under which the femoral component and the acetabular cup were subjected in normal operating conditions. An experimental tribology essay was then performed to simulate the wearing of the components in a Pin over Disc machine. This assay (for which the test specimens were manufactured in medical grade stainless steel AISI-ASTM 316L for the femoral component and high density polyethylene for the acetabular cup was aimed at simulating wear conditions involved in 10 years of continuous operation. A numerical simulation of operational conditions (using the finite element method was performedIn for establishing assay loading conditions to accurately determine where the loads should be applied. The tribology assay led to quantifying the volumetric loss of materials for the system being analysed. It can be concluded that the methodology proposed in this work for estimating the life-span of a prosthetic hip system was valid and accurate by comparing the results with those found in the literature. A statistical validation of the proposed method is plaaned for the future. Key words: Design life; femoral component; acetabular cup; Mexican phenotype; pin-disc configuration.

  2. Factors Influencing Mortality after Bioprosthetic Valve Replacement; A Midterm Outcome

    OpenAIRE

    Hassan Javadzadegan; Amir Javadzadegan; Jafar Mehdizadeh Baghbani

    2013-01-01

    Introduction: Although valve repair is applied routinely nowadays, particularly for mitral regurgitation (MR) or tricuspid regurgitation (TR), valve replacement using prosthetic valves is also common especially in adults. Unfortunately the valve with ideal hemodynamic performance and long-term durability without increasing the risk of bleeding due to long-term anticoagulant therapy has not been introduced. Therefore, patients and physicians must choose either bioprosthetic or mechanical valve...

  3. Autogenous tooth transplantation for replacing a lost tooth: case reports

    Directory of Open Access Journals (Sweden)

    Ji-Youn Kang

    2013-02-01

    Full Text Available The autogenous tooth transplantation is an alternative treatment replacing a missing tooth when a suitable donor tooth is available. It is also a successful treatment option to save significant amount of time and cost comparing implants or conventional prosthetics. These cases, which required single tooth extraction due to deep caries and severe periodontal disease, could have good results by transplanting non-functional but sound donor tooth to the extraction site.

  4. Hip joint replacement

    Science.gov (United States)

    Hip arthroplasty; Total hip replacement; Hip hemiarthroplasty; Arthritis - hip replacement; Osteoarthritis - hip replacement ... Your hip joint is made up of 2 major parts. One or both parts may be replaced during surgery: ...

  5. MR imaging findings of a sequestered disc in the lumbar spine: a comparison with an extruded disc

    International Nuclear Information System (INIS)

    Sim, Su Youn; Park, Ji Seon; Ryu, Kyung Nam; Jin, Wook

    2007-01-01

    To compare the MR findings of a sequestered disc with an extruded disc. MR images of 28 patients with a sequestered disc and 18 patients with an extruded disc were retrospectively reviewed. Patients with sequestered discs were divided into two groups whether definite separation from the parent disc was or was not seen. In the latter group (definite separation not seen) and the extruded disc group of patients, the signal intensities of the herniated discs were compared with the signal intensities of the parent discs and were evaluated on T1-and T2-weighted images. We also assessed the presence of a notch within the herniated disc. In the sequestered disc group of patients (28 discs), only 5 discs (18%) showed obvious separation from the parent disc. Among the remaining 23 discs with indefinite separation, the notch was visible in 14 discs (61%) and 9 discs (39%) had no notch. In the extruded disc group (18 discs), the notch was visible in 2 (11%) discs and the difference between the two groups was statistically significant (ρ 0.0002). The signal intensities of the herniated discs on T1-weighted images were isointense in both the sequestered and extruded discs. The difference of incidence of high signal intensities on T2-weighted images was not statistically significant (ρ = 0.125). It is necessary to consider the possibility of the presence of a sequestered disc when a herniated disc material shows a notch

  6. A STUDY OF INDICATIONS, COMPLICATIONS OF PROSTHETIC VALVES AND PROGNOSIS AFTER TREATMENT OF STUCK VALVE

    Directory of Open Access Journals (Sweden)

    Y. V. Subba Reddy

    2017-03-01

    Full Text Available BACKGROUND Implantation of prosthetic cardiac valves to treat haemodynamically significant valvular diseases has become common; however, it is associated with complications. Thus, this study was intended to evaluate the indications for implantation of prosthetic valve and complications after its implantation and prognosis after treatment of one of its complication, i.e. stuck valve. MATERIALS AND METHODS This was a single-centered study wherein 50 patients who came to the emergency department with stuck valve were assessed. The 2D echocardiography was performed in all patients. Thrombolysis was done and the gradients were reassessed. Further response to treatment and development of complications before and after treatment were observed. RESULTS Of total patients, 60% were females. Mean age group was 30-40 yrs. Most of them were asymptomatic for 6 years and there was lack of compliance in 90% of patients. Most common indication for valve replacement was mitral stenosis (60% followed by mitral regurgitation (20%, aortic regurgitation and aortic stenosis (10% and combined mitral and tricuspid regurgitation (10%. Commonest valve was St. Jude (90%. Pannus was observed in 10% patients and thrombus was observed in 50% patients. Most patients had gradients 45/20 mmHg across mitral valve. In about 90% patients, gradients decreased after thrombolysis (12/5 mmHg. The complications after thrombolysis were hemiparesis (4%, death before thrombolysis (6% and death after thrombolysis (4%. CONCLUSION Considering these results, it can be concluded that prosthetic valves are seldom associated with some complications. Further, thrombolysis can be effective in patients with prosthetic valve thrombosis.

  7. Evaluation of p53 Polymorphism in Patients with Pannus-Derived Prosthetic Dysfunction.

    Science.gov (United States)

    Gursoy, Mustafa Ozan; Karakoyun, Suleyman; Kalcik, Macit; Yesin, Mahmut; Gunduz, Sabahattin; Astarcioğlu, Mehmet Ali; Oğuz, Ali Emrah; Ozkan, Mehmet

    2015-09-01

    Prosthetic valve dysfunction (PVD) due to pannus formation is considered to occur due to a bioreaction to prosthetic material. The p53 gene plays a critical role in apoptosis and cell proliferation. p53 Arg72Pro polymorphism has been found to be associated with coronary stent restenosis, but has not yet been studied in prosthetic heart valve dysfunction. The study aim was to evaluate the association between pannus-derived PVD and p53 G72C(Arg72Pro) polymorphism. This single-center, prospective study included 25 patients (20 females, five males; mean age 45.6 +/- 12.5 years; group 1) who underwent redo valve surgery due to PVD, and 49 age- and gender-matched control patients (44 females, five males; mean age 47.3 +/- 12.2 years; group 2) with normofunctional prostheses. The prostheses were examined using transthoracic and transesophageal echocardiography. Analyses of p53 G72C(Arg72Pro) polymorphism were performed using Roche LightCyler 2.0 Real-time polymerase chain reaction. The most common location of replaced valves was the mitral position in both groups (88% and 89.8%, respectively). In group 1, normal alleles (GG) were observed in 12 patients (48%), while one patient (4%) showed a homozygous mutation (GC) and 12 patients (48%) showed a heterozygous mutation (CC). In group 2, 21 patients (42.9%) had normal alleles (GG), while four (8.2%) had a homozygous mutation (CC) and 24 (48.9%) had a heterozygous mutation (GC). No significant difference was observed between the groups with regards to p53 Arg72Pro polymorphism (p = 0.769). In patients with prosthetic valves, the underlying mechanism behind pannus formation is unrelated to p53 Arg72Pro polymorphism.

  8. Exophiala (Wangiella dermatitidis Prosthetic Aortic Valve Endocarditis and Prosthetic Graft Infection in an Immune Competent Patient

    Directory of Open Access Journals (Sweden)

    Jay S. Berger

    2017-01-01

    Full Text Available Exophiala (Wangiella dermatitidis is an emerging dematiaceous fungus associated with high mortality rates and is a rare cause of endocarditis. We describe the first case of E. dermatitidis endocarditis of a prosthetic aortic valve and aortic graft in an immune competent patient with no clear risk factors of hematological acquisition.

  9. Retina image–based optic disc segmentation

    Directory of Open Access Journals (Sweden)

    Ching-Lin Wang

    2016-05-01

    Full Text Available The change of optic disc can be used to diagnose many eye diseases, such as glaucoma, diabetic retinopathy and macular degeneration. Moreover, retinal blood vessel pattern is unique for human beings even for identical twins. It is a highly stable pattern in biometric identification. Since optic disc is the beginning of the optic nerve and main blood vessels in retina, it can be used as a reference point of identification. Therefore, optic disc segmentation is an important technique for developing a human identity recognition system and eye disease diagnostic system. This article hence presents an optic disc segmentation method to extract the optic disc from a retina image. The experimental results show that the optic disc segmentation method can give impressive results in segmenting the optic disc from a retina image.

  10. Pre prosthetic reconstruction of alveolar ridge

    Directory of Open Access Journals (Sweden)

    Prabhuji Munivenkatappa Lakshmaiahenkatesh

    2011-01-01

    Full Text Available Dento-alveolar bony defects are common and occur due to a variety of causes, such as, pulpal pathology, traumatic tooth extraction, advanced periodontal disease, implant failure, tumor or congenital anomalies. These defects often cause a significant problem in dental treatment and rehabilitation. Many techniques exist for effective soft and hard tissue augmentation. The approach is largely based on the extent of the defect and specific procedures to be performed for the implant or prosthetic rehabilitation. This article presents case reports of soft and hard tissue ridge augmentation.

  11. Prevention of Infection in Orthopedic Prosthetic Surgery.

    Science.gov (United States)

    Chirca, Ioana; Marculescu, Camelia

    2017-06-01

    Total joint arthroplasty is a generally safe orthopedic procedure; however, infection is a potentially devastating complication. Multiple risk factors have been identified for development of prosthetic joint infections. Identification of patients at risk and preoperative correction of known risk factors, such as smoking, diabetes mellitus, anemia, malnutrition, and decolonization of Staphylococcus carriers, represent well-established actions to decrease the infection risk. Careful operative technique, proper draping and skin preparation, and appropriate selection and dosing of antimicrobials for perioperative prophylaxis are also very important in prevention of infection. Published by Elsevier Inc.

  12. The PANDA Endcap Disc DIRC

    Science.gov (United States)

    Föhl, K.; Ali, A.; Belias, A.; Dzhygadlo, R.; Gerhardt, A.; Götzen, K.; Kalicy, G.; Krebs, M.; Lehmann, D.; Nerling, F.; Patsyuk, M.; Peters, K.; Schepers, G.; Schmitt, L.; Schwarz, C.; Schwiening, J.; Traxler, M.; Böhm, M.; Eyrich, W.; Lehmann, A.; Pfaffinger, M.; Uhlig, F.; Düren, M.; Etzelmüller, E.; Hayrapetyan, A.; Kreutzfeld, K.; Merle, O.; Rieke, J.; Schmidt, M.; Wasem, T.; Achenbach, P.; Cardinali, M.; Hoek, M.; Lauth, W.; Schlimme, S.; Sfienti, C.; Thiel, M.

    2018-02-01

    Positively identifying charged kaons in the PANDA forward endcap solid angle range can be achieved with the Endcap Disc DIRC, allowing kaon-pion separation from 1 up to 4 GeV/c with a separation power of at least 3 standard deviations. Design, performance, and components of this DIRC are given, including the recently introduced TOFPET-ASIC based read-out. Results of a prototype operated in a test beam at DESY in 2016 are shown.

  13. A Low-Cost Auto-Stop Hydraulic Press for Making KBr Disc

    Science.gov (United States)

    Hon, Ping-Kay

    1998-05-01

    A hydraulic press fitted with an adjustable torque wrench, together with a stand made of iron bars will form an auto-stop hydraulic press for making KBr disc in IR studies. Total material cost is about $100. All parts are readily available from the local hardware stores. The modified torque wrench is also useful to replace the lever in the standard laboratory press.

  14. Cyborg beast: a low-cost 3d-printed prosthetic hand for children with upper-limb differences.

    Science.gov (United States)

    Zuniga, Jorge; Katsavelis, Dimitrios; Peck, Jean; Stollberg, John; Petrykowski, Marc; Carson, Adam; Fernandez, Cristina

    2015-01-20

    There is an increasing number of children with traumatic and congenital hand amputations or reductions. Children's prosthetic needs are complex due to their small size, constant growth, and psychosocial development. Families' financial resources play a crucial role in the prescription of prostheses for their children, especially when private insurance and public funding are insufficient. Electric-powered (i.e., myoelectric) and body-powered (i.e., mechanical) devices have been developed to accommodate children's needs, but the cost of maintenance and replacement represents an obstacle for many families. Due to the complexity and high cost of these prosthetic hands, they are not accessible to children from low-income, uninsured families or to children from developing countries. Advancements in computer-aided design (CAD) programs, additive manufacturing, and image editing software offer the possibility of designing, printing, and fitting prosthetic hands devices at a distance and at very low cost. The purpose of this preliminary investigation was to describe a low-cost three-dimensional (3D)-printed prosthetic hand for children with upper-limb reductions and to propose a prosthesis fitting methodology that can be performed at a distance. No significant mean differences were found between the anthropometric and range of motion measurements taken directly from the upper limbs of subjects versus those extracted from photographs. The Bland and Altman plots show no major bias and narrow limits of agreements for lengths and widths and small bias and wider limits of agreements for the range of motion measurements. The main finding of the survey was that our prosthetic device may have a significant potential to positively impact quality of life and daily usage, and can be incorporated in several activities at home and in school. This investigation describes a low-cost 3D-printed prosthetic hand for children and proposes a distance fitting procedure. The Cyborg Beast

  15. Differences in the stress distribution in the distal femur between patellofemoral joint replacement and total knee replacement: a finite element study

    Directory of Open Access Journals (Sweden)

    van Jonbergen Hans-Peter W

    2012-06-01

    Full Text Available Abstract Background Patellofemoral joint replacement is a successful treatment option for isolated patellofemoral osteoarthritis. However, results of later conversion to total knee replacement may be compromised by periprosthetic bone loss. Previous clinical studies have demonstrated a decrease in distal femoral bone mineral density after patellofemoral joint replacement. It is unclear whether this is due to periprosthetic stress shielding. The main objective of the current study was to evaluate the stress shielding effect of prosthetic replacement with 2 different patellofemoral prosthetic designs and with a total knee prosthesis. Methods We developed a finite element model of an intact patellofemoral joint, and finite element models of patellofemoral joint replacement with a Journey PFJ prosthesis, a Richards II prosthesis, and a Genesis II total knee prosthesis. For each of these 4 finite element models, the average Von Mises stress in 2 clinically relevant regions of interest were evaluated during a simulated squatting movement until 120 degrees of flexion. Results During deep knee flexion, in the anterior region of interest, the average Von Mises stress with the Journey PFJ design was comparable to the physiological knee, while reduced by almost 25% for both the Richards II design and the Genesis II total knee joint replacement design. The average Von Mises stress in the supracondylar region of interest was similar for both patellofemoral prosthetic designs and the physiological model, with slightly lower stress for the Genesis II design. Conclusions Patellofemoral joint replacement results in periprosthetic stress-shielding, although to a smaller degree than in total knee replacement. Specific patellofemoral prosthetic design properties may result in differences in femoral stress shielding.

  16. Differences in the stress distribution in the distal femur between patellofemoral joint replacement and total knee replacement: a finite element study

    Science.gov (United States)

    2012-01-01

    Background Patellofemoral joint replacement is a successful treatment option for isolated patellofemoral osteoarthritis. However, results of later conversion to total knee replacement may be compromised by periprosthetic bone loss. Previous clinical studies have demonstrated a decrease in distal femoral bone mineral density after patellofemoral joint replacement. It is unclear whether this is due to periprosthetic stress shielding. The main objective of the current study was to evaluate the stress shielding effect of prosthetic replacement with 2 different patellofemoral prosthetic designs and with a total knee prosthesis. Methods We developed a finite element model of an intact patellofemoral joint, and finite element models of patellofemoral joint replacement with a Journey PFJ prosthesis, a Richards II prosthesis, and a Genesis II total knee prosthesis. For each of these 4 finite element models, the average Von Mises stress in 2 clinically relevant regions of interest were evaluated during a simulated squatting movement until 120 degrees of flexion. Results During deep knee flexion, in the anterior region of interest, the average Von Mises stress with the Journey PFJ design was comparable to the physiological knee, while reduced by almost 25% for both the Richards II design and the Genesis II total knee joint replacement design. The average Von Mises stress in the supracondylar region of interest was similar for both patellofemoral prosthetic designs and the physiological model, with slightly lower stress for the Genesis II design. Conclusions Patellofemoral joint replacement results in periprosthetic stress-shielding, although to a smaller degree than in total knee replacement. Specific patellofemoral prosthetic design properties may result in differences in femoral stress shielding. PMID:22704638

  17. Normal modes of Bardeen discs

    International Nuclear Information System (INIS)

    Verdaguer, E.

    1983-01-01

    The short wavelength normal modes of self-gravitating rotating polytropic discs in the Bardeen approximation are studied. The discs' oscillations can be seen in terms of two types of modes: the p-modes whose driving forces are pressure forces and the r-modes driven by Coriolis forces. As a consequence of differential rotation coupling between the two takes place and some mixed modes appear, their properties can be studied under the assumption of weak coupling and it is seen that they avoid the crossing of the p- and r-modes. The short wavelength analysis provides a basis for the classification of the modes, which can be made by using the properties of their phase diagrams. The classification is applied to the large wavelength modes of differentially rotating discs with strong coupling and to a uniformly rotating sequence with no coupling, which have been calculated in previous papers. Many of the physical properties and qualitative features of these modes are revealed by the analysis. (author)

  18. Candida glabrata prosthetic joint infection, successfully treated with anidulafungin: A case report and review of the literature.

    Science.gov (United States)

    Koutserimpas, Christos; Samonis, George; Velivassakis, Emmanouil; Iliopoulou-Kosmadaki, Stylliani; Kontakis, Georgios; Kofteridis, Diamantis P

    2018-04-01

    Non-albicans Candida prosthetic joint infection (PJI) is extremely rare. A case of a Candida glabrata knee PJI is a 68-year-old splenectomised female smoker, suffering from chronic obstructive pulmonary disease (COPD) and alcoholism is reported. The patient presented with a peri-prosthetic fracture, 15 years after total knee replacement surgery. Cultures of the intraoperative peri-prosthetic tissue and materials yielded C. glabrata, as well as a methicillin-resistant S. epidermitis. The patient was treated with anidulafungin and vancomycin. The knee prosthetic joint was removed and cement-spacer with vancomycin and gentamycin was placed. Additionally, an external fixation was performed. A second stage revision surgery was planned, after completion of the antimicrobial and antifungal treatment. The patient is followed up for 4 months without signs, symptoms or findings of infection. PJI Candida infections require a high clinical suspicion index. It is of utmost importance to report these cases, since there is no consensus yet of the proper antifungal treatment. Furthermore, a literature review regarding treatment of those cases is provided. First-line treatment with an echinocandin seems most proper, due to their fungicidal properties, their effectiveness against biofilm, as well as their minimal toxicity, making them ideal for long-term use. Further experience is needed, for better understanding the disease's pathogenesis and optimal treatment. © 2017 Blackwell Verlag GmbH.

  19. Prosthetic Rehabilitation in Children: An Alternative Clinical Technique

    Directory of Open Access Journals (Sweden)

    Nádia Carolina Teixeira Marques

    2013-01-01

    Full Text Available Complete and partial removable dentures have been used successfully in numerous patients with oligodontia and/or anodontia. However, there is little information in the literature regarding the principles and guidelines to prosthetic rehabilitation for growing children. This case report describes the management of a young child with oligodontia as well as the treatment planning and the prosthetic rehabilitation technique.

  20. 21 CFR 890.3025 - Prosthetic and orthotic accessory.

    Science.gov (United States)

    2010-04-01

    ... (CONTINUED) MEDICAL DEVICES PHYSICAL MEDICINE DEVICES Physical Medicine Prosthetic Devices § 890.3025... intended for medical purposes to support, protect, or aid in the use of a cast, orthosis (brace), or prosthesis. Examples of prosthetic and orthotic accessories include the following: A pelvic support band and...

  1. Successful thrombolysis of aortic prosthetic valve thrombosis during ...

    African Journals Online (AJOL)

    Successful thrombolysis of aortic prosthetic valve thrombosis during first trimester of pregnancy. A Shukla, AP Raval, R Shah. Abstract. Prosthetic heart valve thrombosis during pregnancy is life-threatening. Standard surgical treatment using cardiopulmonary bypass carries high maternal and fetal complications. Here we ...

  2. Stiffness and hysteresis properties of some prosthetic feet

    NARCIS (Netherlands)

    van Jaarsveld, H.W.L.; Grootenboer, H.J.; de Vries, J.; Koopman, Hubertus F.J.M.

    1990-01-01

    A prosthetic foot is an important element of a prosthesis, although it is not always fully recognized that the properties of the foot, along with the prosthetic knee joint and the socket, are in part responsible for the stability and metabolic energy cost during walking. The stiffness and the

  3. Prosthetic prescription in the Netherlands: An interview with clinical experts

    NARCIS (Netherlands)

    Van Der Linde, H.; Geertzen, J.H.B.; Hofstad, C.J.; Van Limbeek, Jacques; Postema, K.

    2004-01-01

    In the process of guideline development for prosthetic prescription in the Netherlands the authors made a study of the daily clinical practice of lower limb prosthetics. Besides the evidence-based knowledge from literature the more implicit knowledge from clinical experts is of importance for

  4. 38 CFR 17.150 - Prosthetic and similar appliances.

    Science.gov (United States)

    2010-07-01

    ... appliances. 17.150 Section 17.150 Pensions, Bonuses, and Veterans' Relief DEPARTMENT OF VETERANS AFFAIRS MEDICAL Prosthetic, Sensory, and Rehabilitative Aids § 17.150 Prosthetic and similar appliances... appliances including invalid lifts and therapeutic and rehabilitative devices, and special clothing made...

  5. Review of Prosthetic Joint Infection from Listeria monocytogenes.

    Science.gov (United States)

    Bader, Gilbert; Al-Tarawneh, Mohammed; Myers, James

    2016-12-01

    Prosthetic joint infection from Listeria monocytogenes is rare. We decided to shed light on this illness and review the reported cases to better understand its characteristics. We conducted a comprehensive review of the English literature using PubMed. We also included one case that we had managed. We found 25 cases of prosthetic joint infection from L. monocytogenes reported individually and a retrospective study of 43 cases of joint and bone listerial infection, including 34 with prosthetic joint infection, conducted in France. We have described their clinical and para-clinical features and tried to elaborate on the pathophysiology, treatment, and prevention. Prosthetic joint infection from L. monocytogenes is mainly late. Systemic inflammation may be absent. Although rare, it must be suspected in patients at high risk for both prosthetic joint and listerial infections. In addition, those patients must be instructed on appropriate preventive measures.

  6. Nitinol for Prosthetic and Orthotic Applications

    Science.gov (United States)

    Henderson, Emma; Buis, Arjan

    2011-07-01

    As global populations age, conditions such as stroke and diabetes require individuals to use rehabilitation technology for many years to come due to chronic musculoskeletal, sensory, and other physical impairments. One in four males currently aged 45 will experience a stroke within 40 years and will often require access to prolonged rehabilitation. In addition, worldwide, one individual loses a limb every 30 s due to the complications of diabetes. As a result, innovative ideas are required to devise more effective prosthetic and orthotic devices to enhance quality of life. While Nitinol has already found much favor within the biomedical industry, one area, which has not yet exploited its unique properties, is in the field of physical rehabilitation, ranging from prosthetic and orthotic devices to assistive technology such as wheelchairs. Improved intervention capabilities based on materials such as Nitinol have the potential to vastly improve patients' quality of life and in the case of orthoses, may even reduce the severity of the condition over time. It is hoped that this study will spark discussion and interest for the materials community in a field which has yet to be fully exploited.

  7. Is the Prosthetic Homologue Necessary for Embodiment?

    Science.gov (United States)

    Dornfeld, Chelsea; Swanston, Michelle; Cassella, Joseph; Beasley, Casey; Green, Jacob; Moshayev, Yonatan; Wininger, Michael

    2016-01-01

    Embodiment is the process by which patients with limb loss come to accept their peripheral device as a natural extension of self. However, there is little guidance as to how exacting the prosthesis must be in order for embodiment to take place: is it necessary for the prosthetic hand to look just like the absent hand? Here, we describe a protocol for testing whether an individual would select a hand that looks like their own from among a selection of five hands, and whether the hand selection (regardless of homology) is consistent across multiple exposures to the same (but reordered) set of candidate hands. Pilot results using healthy volunteers reveals that hand selection is only modestly consistent, and that selection of the prosthetic homologue is atypical (61 of 192 total exposures). Our protocol can be executed in minutes, and makes use of readily available equipment and softwares. We present both a face-to-face and a virtual protocol, for maximum flexibility of implementation.

  8. Proto-planetary disc evolution and dispersal

    Science.gov (United States)

    Rosotti, Giovanni Pietro

    2015-05-01

    Planets form from gas and dust discs in orbit around young stars. The timescale for planet formation is constrained by the lifetime of these discs. The properties of the formed planetary systems depend thus on the evolution and final dispersal of the discs, which is the main topic of this thesis. Observations reveal the existence of a class of discs called "transitional", which lack dust in their inner regions. They are thought to be the last stage before the complete disc dispersal, and hence they may provide the key to understanding the mechanisms behind disc evolution. X-ray photoevaporation and planet formation have been studied as possible physical mechanisms responsible for the final dispersal of discs. However up to now, these two phenomena have been studied separately, neglecting any possible feedback or interaction. In this thesis we have investigated what is the interplay between these two processes. We show that the presence of a giant planet in a photo-evaporating disc can significantly shorten its lifetime, by cutting the inner regions from the mass reservoir in the exterior of the disc. This mechanism produces transition discs that for a given mass accretion rate have larger holes than in models considering only X-ray photo-evaporation, constituting a possible route to the formation of accreting transition discs with large holes. These discs are found in observations and still constitute a puzzle for the theory. Inclusion of the phenomenon called "thermal sweeping", a violent instability that can destroy a whole disc in as little as 10 4 years, shows that the outer disc left can be very short-lived (depending on the X-ray luminosity of the star), possibly explaining why very few non accreting transition discs are observed. However the mechanism does not seem to be efficient enough to reconcile with observations. In this thesis we also show that X-ray photo-evaporation naturally explains the observed correlation between stellar masses and accretion

  9. Mitral Valve Replacement with a Pulmonary Autograft in an Infant

    Directory of Open Access Journals (Sweden)

    Yong Ho Jeong

    2018-04-01

    Full Text Available A 76-day-old infant weighing 3.4 kg was referred for surgical intervention for severe mitral valve stenoinsufficiency caused by leaflet fibrosis and calcification. He had experienced a cerebral infarction in the left middle cerebral artery territory, which was deemed attributable to an embolism of a calcified particle from the dysmorphic mitral valve. Because mitral valve replacement using a prosthetic valve was not feasible in this small baby, mitral valve replacement with a pulmonary autograft was performed. After a brief period of extracorporeal membrane oxygenation (ECMO support, he was weaned from ECMO and was discharged home without further cardiovascular complications.

  10. [Research progress of intervertebral disc endogenous stem cells for intervertebral disc regeneration].

    Science.gov (United States)

    Liang, Hang; Deng, Xiangyu; Shao, Zengwu

    2017-10-01

    To summarize the research progress of intervertebral disc endogenous stem cells for intervertebral disc regeneration and deduce the therapeutic potential of endogenous repair for intervertebral disc degeneration. The original articles about intervertebral disc endogenous stem cells for intervertebral disc regeneration were extensively reviewed; the reparative potential in vivo and the extraction and identification in vitro of intervertebral disc endogenous stem cells were analyzed; the prospect of endogenous stem cells for intervertebral disc regeneration was predicted. Stem cell niche present in the intervertebral discs, from which stem cells migrate to injured tissues and contribute to tissues regeneration under certain specific microenvironment. Moreover, the migration of stem cells is regulated by chemokines system. Tissue specific progenitor cells have been identified and successfully extracted and isolated. The findings provide the basis for biological therapy of intervertebral disc endogenous stem cells. Intervertebral disc endogenous stem cells play a crucial role in intervertebral disc regeneration. Therapeutic strategy of intervertebral disc endogenous stem cells is proven to be a promising biological approach for intervertebral disc regeneration.

  11. Photopolymerized materials and patterning for improved performance of neural prosthetics

    Science.gov (United States)

    Tuft, Bradley William

    Neural prosthetics are used to replace or substantially augment remaining motor and sensory functions of neural pathways that were lost or damaged due to physical trauma, disease, or genetics. However, due to poor spatial signal resolution, neural prostheses fail to recapitulate the intimate, precise interactions inherent to neural networks. Designing materials and interfaces that direct de novo nerve growth to spatially specific stimulating elements is, therefore, a promising method to enhance signal specificity and performance of prostheses such as the successful cochlear implant (CI) and the developing retinal implant. In this work, the spatial and temporal reaction control inherent to photopolymerization was used to develop methods to generate micro and nanopatterned materials that direct neurite growth from prosthesis relevant neurons. In particular, neurite growth and directionality has been investigated in response to physical, mechanical, and chemical cues on photopolymerized surfaces. Spiral ganglion neurons (SGNs) serve as the primary neuronal model as they are the principal target for CI stimulation. The objective of the research is to rationally design materials that spatially direct neurite growth and to translate fundamental understanding of nerve cell-material interactions into methods of nerve regeneration that improve neural prosthetic performance. A rapid, single-step photopolymerization method was developed to fabricate micro and nanopatterned physical cues on methacrylate surfaces by selectively blocking light with photomasks. Feature height is readily tuned by modulating parameters of the photopolymerizaiton including initiator concentration and species, light intensity, separation distance from the photomask, and radiation exposure time. Alignment of neural elements increases significantly with increasing feature amplitude and constant periodicity, as well as with decreasing periodicity and constant amplitude. SGN neurite alignment strongly

  12. Vent-induced prosthetic leaflet thrombosis treated by open-heart valve-in-valve implantation.

    Science.gov (United States)

    Stamm, Christof; Pasic, Miralem; Buz, Semih; Hetzer, Roland

    2015-09-01

    A patient required emergency mitral valve replacement and extracorporeal membrane oxygenation (ECMO) support for acute biventricular failure. The left ventricular (LV) vent inserted via the left upper pulmonary vein induced thrombotic immobilization of a prosthetic valve leaflet, with significant intra-prosthesis regurgitation after ECMO explantation. Therefore, the left atrium was opened on the beating heart during conventional extracorporeal circulation, all prosthesis leaflets were excised and a 29-mm expandable Edwards Sapien prosthesis was inserted within the scaffold of the original prosthesis under direct vision. This case illustrates the benefits and potential problems of LV venting on ECMO support, and a rapid and safe way of replacing the prosthesis leaflets in a critical situation. © The Author 2015. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.

  13. Live 3D TEE demonstrates and guides the management of prosthetic mitral valve obstruction.

    Science.gov (United States)

    Chahal, Mangeet; Pandya, Utpal; Adlakha, Satjit; Khouri, Samer J

    2011-08-01

    A 43-year-old woman, with a remote history of rheumatic mitral stenosis and a St. Jude prosthetic mitral valve replacement, presented with shortness of breath and palpitations, shortly after a long flight. On admission, atrial fibrillation with a rapid ventricular response was noted in the setting of a long history of noncompliance with her anticoagulation. Transesophageal echocardiography (TEE) demonstrated multiple laminated thrombi in the left atrial appendage. Live three-dimensional (3D) TEE confirmed this diagnosis and demonstrated an immobile posterior leaflet of the mitral prosthesis, which had direct implications in her management. She successfully underwent surgery for mitral valve replacement, left atrial appendage ligation, and a Maze procedure on the following day. The multiple thrombi within the atrial appendage were confirmed intraoperatively and pannus formation was determined to be the etiology of the leaflet immobility. © 2011, Wiley Periodicals, Inc.

  14. Biomaterials for intervertebral disc regeneration and repair.

    Science.gov (United States)

    Bowles, Robert D; Setton, Lori A

    2017-06-01

    The intervertebral disc contributes to motion, weight bearing, and flexibility of the spine, but is susceptible to damage and morphological changes that contribute to pathology with age and injury. Engineering strategies that rely upon synthetic materials or composite implants that do not interface with the biological components of the disc have not met with widespread use or desirable outcomes in the treatment of intervertebral disc pathology. Here we review bioengineering advances to treat disc disorders, using cell-supplemented materials, or acellular, biologically based materials, that provide opportunity for cell-material interactions and remodeling in the treatment of intervertebral disc disorders. While a field still in early development, bioengineering-based strategies employing novel biomaterials are emerging as promising alternatives for clinical treatment of intervertebral disc disorders. Copyright © 2017 Elsevier Ltd. All rights reserved.

  15. Development of rupture discs for the FBTR

    International Nuclear Information System (INIS)

    Chetal, S.C.; Raju, C.; Anandkumar, V.; Seetharaman, V.; Rajan, K.K.

    1984-01-01

    Rupture discs are required as a safety device for protecting the secondary sodium circuit and its components against high pressure surges due to accidental water steam leaks in sodium heated steam generator and the consequent sodium water reaction. For identical reasons, rupture discs are also required on the vessels used for decontamination of sodium components. Reverse buckling knife blade concept with austenitic stainless steel disc has been developed for the rupture disc assemblies required for Fast Breeder Test Reactor (FBTR). Hydroforming process without any die has been used for disc fabrication. One rupture disc assembly required for steam generator is undergoing sodium endurance test and has accumulated 4,500 hours. The present status of development work as demonstrated by room temperature experimental results as well as the scope for future work are discussed. (author)

  16. A Report Of Two Cases Of Uncemented Total Hip Replacement In ...

    African Journals Online (AJOL)

    This is a report of two sickle cell patients (HbSS) with advanced osteoarthritis of the right hip. The patients were in Ficat and Arlet\\'s stage 3 and 4 respectively. Both were females aged 23 and 46 years and they had uncemented hydroxyapatite coated omnifit (Stryker Howmedica Osteonics) total hip prosthetic replacement.

  17. Physiological pattern of lumbar disc height

    International Nuclear Information System (INIS)

    Biggemann, M.; Frobin, W.; Brinckmann, P.

    1997-01-01

    Purpose of this study is to present a new method of quantifying objectively the height of all discs in lateral radiographs of the lumbar spine and of analysing the normal craniocaudal sequence pattern of lumbar disc heights. Methods: The new parameter is the ventrally measured disc height corrected for the dependence on the angle of lordosis by normalisation to mean angles observed in the erect posture of healthy persons. To eliminate radiographic magnification, the corrected ventral height is related to the mean depth of the cranially adjoining vertebra. In this manner lumbar disc heights were objectively measured in young, mature and healthy persons (146 males and 65 females). The craniocaudal sequence pattern was analysed by mean values from all persons and by height differences of adjoining discs in each individual lumbar spine. Results: Mean normative values demonstrated an increase in disc height between L1/L2 and L4/L5 and a constant or decreasing disc height between L4/L5 and L5/S1. However, this 'physiological sequence of disc height in the statistical mean' was observed in only 36% of normal males and 55% of normal females. Conclusion: The radiological pattern of the 'physiological sequence of lumbar disc height' leads to a relevant portion of false positive pathological results especially at L4/L5. An increase of disc height from L4/L5 to L5/S1 may be normal. The recognition of decreased disc height should be based on an abrupt change in the heights of adjoining discs and not on a deviation from a craniocaudal sequence pattern. (orig.) [de

  18. The non-invasive investigation of lumbar disc degeneration in patients with chronic low back pain

    International Nuclear Information System (INIS)

    Buirski, G.

    1989-01-01

    The painful degenerate disc is a recognised cause of low back pain. Magnetic Resonance Imaging (MRI) has now replaced discography in the non-invasive assessment of disk degeneration. However, the prohibitive capital expense of MRI and the small number of MR units in Australia produce limitations in clinical access. In contrast, Computed Tomography (CT) is readily available and is performed in most patients prior to MRI referral. This prospective study was undertaken to determine whether preliminary CT could offer any information about disc degeneration and so reduce the demand on a MRI scanner. 30 consecutive patients were studied all of whom had both CT and MRI examinations. Of a total 107 discs examined by both techniques, MRI was able to identify 37 degenerate discs. Conclusive evidence of degeneration (i.e. the presence of intervertebral gas) was only seen in 3 discs at CT (1 patient). Of the 29 posterior disc bulges found on CT, all were both bulging and degenerate on MRI. Indications for MRI based on the CT findings are recommended. Using these criteria, 13% (4 patients) of this study group could have avoided an expensive and unnecessary MR investigation. A useful algorithm for the investigation and assessment of patients with chronic low back pain is discussed. 8 refs., 5 figs., 1 tab

  19. Debris disc constraints on planetesimal formation

    Science.gov (United States)

    Krivov, Alexander V.; Ide, Aljoscha; Löhne, Torsten; Johansen, Anders; Blum, Jürgen

    2018-02-01

    Two basic routes for planetesimal formation have been proposed over the last decades. One is a classical `slow-growth' scenario. Another one is particle concentration models, in which small pebbles are concentrated locally and then collapse gravitationally to form planetesimals. Both types of models make certain predictions for the size spectrum and internal structure of newly born planetesimals. We use these predictions as input to simulate collisional evolution of debris discs left after the gas dispersal. The debris disc emission as a function of a system's age computed in these simulations is compared with several Spitzer and Herschel debris disc surveys around A-type stars. We confirm that the observed brightness evolution for the majority of discs can be reproduced by classical models. Further, we find that it is equally consistent with the size distribution of planetesimals predicted by particle concentration models - provided the objects are loosely bound `pebble piles' as these models also predict. Regardless of the assumed planetesimal formation mechanism, explaining the brightest debris discs in the samples uncovers a `disc mass problem'. To reproduce such discs by collisional simulations, a total mass of planetesimals of up to ˜1000 Earth masses is required, which exceeds the total mass of solids available in the protoplanetary progenitors of debris discs. This may indicate that stirring was delayed in some of the bright discs, that giant impacts occurred recently in some of them, that some systems may be younger than previously thought or that non-collisional processes contribute significantly to the dust production.

  20. Lumbar disc arthroplasty: indications, biomechanics, types, and radiological criteria

    International Nuclear Information System (INIS)

    Baur-Melnyk, A.; Reiser, M.F.; Birkenmaier, C.

    2006-01-01

    Lumbar total disc replacement (TDR) was developed to treat a painful degenerative lumbar motion segment while avoiding the disadvantages of fusion surgery, such as adjacent segment instabilities. Early clinical results with TDR have shown a significant reduction in low back pain and a significant improvement in disability scores. When compared to fusion, the results with TDR tend to be superior in the short-term follow-up and initial rehabilitation is faster. The radiological assessment is an integral part of the preoperative work-up. Plain X-rays of the lumbar spine should be complemented by flexion - extension views in order to assess residual segmental mobility. Computed tomography is used to exclude osteoarthritis of the zygapophyseal joints, Baastrup's disease (kissing spines) and other sources of low back pain. Magnetic resonance imaging is useful to exclude substantial disc protrusions; it allows for the detection of disc dehydration and bone marrow edema in the case of activated spondylochondrosis. If osteoporosis is suspected, an osteodensitometry of the lumbar spine should be performed. Postoperative plain X-rays should include antero-posterior and lateral views as well as flexion - extension views in the later postoperative course. Measurements should determine the disc space height in the lateral view, the segmental and total lumbar lordosis as well as the segmental mobility in the flexion - extension views. The ideal position of a TDR is exactly central in the ap-view and close to the dorsal border of the vertebral endplates in the lateral view. Malpositioning may cause segmental hyperlordosis and unbalanced loading of the endplates with the risk of implant subsidence and migration. (orig.) [de

  1. Viability of Controlling Prosthetic Hand Utilizing Electroencephalograph (EEG) Dataset Signal

    Science.gov (United States)

    Miskon, Azizi; A/L Thanakodi, Suresh; Raihan Mazlan, Mohd; Mohd Haziq Azhar, Satria; Nooraya Mohd Tawil, Siti

    2016-11-01

    This project presents the development of an artificial hand controlled by Electroencephalograph (EEG) signal datasets for the prosthetic application. The EEG signal datasets were used as to improvise the way to control the prosthetic hand compared to the Electromyograph (EMG). The EMG has disadvantages to a person, who has not used the muscle for a long time and also to person with degenerative issues due to age factor. Thus, the EEG datasets found to be an alternative for EMG. The datasets used in this work were taken from Brain Computer Interface (BCI) Project. The datasets were already classified for open, close and combined movement operations. It served the purpose as an input to control the prosthetic hand by using an Interface system between Microsoft Visual Studio and Arduino. The obtained results reveal the prosthetic hand to be more efficient and faster in response to the EEG datasets with an additional LiPo (Lithium Polymer) battery attached to the prosthetic. Some limitations were also identified in terms of the hand movements, weight of the prosthetic, and the suggestions to improve were concluded in this paper. Overall, the objective of this paper were achieved when the prosthetic hand found to be feasible in operation utilizing the EEG datasets.

  2. Salmonella Typhimurium gastroenteritis leading to chronic prosthetic vascular graft infection.

    Science.gov (United States)

    Cullinan, Milo; Clarke, Michael; Dallman, Tim; Peart, Steven; Wilson, Deborah; Weiand, Daniel

    2017-08-01

    Introduction. It is estimated up to 6 % of prosthetic vascular grafts become infected. Staphylococcus aureus is predominant in early infection and coagulase-negative staphylococci are predominant in late infections. Enterobacteriaceae cause 14-40 % of prosthetic vascular graft infections. This is, to our knowledge the first reported case of Salmonella gastroenteritis causing chronic prosthetic vascular graft infection (PVGI). Case presentation. A 57 years old lady presented with signs and symptoms of prosthetic vascular graft infection. Three years earlier, she had undergone a prosthetic axillo-femoral bypass graft for critical limb ischaemia. The infected prosthetic vascular graft was removed and Salmonella Typhimurium was isolated on culture. In the intervening period, Salmonella Typhimurium was isolated from a faecal specimen, collected during an episode of acute gastroenteritis. Whole-genome sequencing (WGS) showed that the respective Salmonella Typhimurium isolates differed by only a single nucleotide polymorphism (SNP). Salmonella Typhimurium was not isolated on culture of a faecal specimen collected five days following cessation of antimicrobial therapy. Six months after removal of the prosthetic graft, the patient remains under follow-up for her peripheral vascular disease, which currently requires no further surgical intervention. Conclusion. This case has clear implications for the management of chronic PVGI. It is vital to collect high-quality surgical specimens for microbiological analysis and empirical choices of antibiotics are unlikely to cover all potential pathogens. It may also be prudent to enquire about a history of acute gastroenteritis when assessing patients presenting with chronic PVGI.

  3. Fluid dynamics of the magnetic field dependent thermosolutal convection and viscosity between coaxial contracting discs

    Science.gov (United States)

    Khan, Aamir; Shah, Rehan Ali; Shuaib, Muhammad; Ali, Amjad

    2018-06-01

    The effects of magnetic field dependent (MFD) thermosolutal convection and MFD viscosity of the fluid dynamics are investigated between squeezing discs rotating with different velocities. The unsteady constitutive expressions of mass conservation, modified Navier-Stokes, Maxwell and MFD thermosolutal convection are coupled as a system of ordinary differential equations. The corresponding solutions for the transformed radial and azimuthal momentum as well as solutions for the azimuthal and axial induced magnetic field equations are determined, also the MHD pressure and torque which the fluid exerts on the upper disc is derived and discussed in details. In the case of smooth discs the self-similar equations are solved using Homotopy Analysis Method (HAM) with appropriate initial guesses and auxiliary parameters to produce an algorithm with an accelerated and assured convergence. The validity and accuracy of HAM results is proved by comparison of the HAM solutions with numerical solver package BVP4c. It has been shown that magnetic Reynolds number causes to decrease magnetic field distributions, fluid temperature, axial and tangential velocity. Also azimuthal and axial components of magnetic field have opposite behavior with increase in MFD viscosity. Applications of the study include automotive magneto-rheological shock absorbers, novel aircraft landing gear systems, heating up or cooling processes, biological sensor systems and biological prosthetic etc.

  4. Sensory feedback in upper limb prosthetics.

    Science.gov (United States)

    Antfolk, Christian; D'Alonzo, Marco; Rosén, Birgitta; Lundborg, Göran; Sebelius, Fredrik; Cipriani, Christian

    2013-01-01

    One of the challenges facing prosthetic designers and engineers is to restore the missing sensory function inherit to hand amputation. Several different techniques can be employed to provide amputees with sensory feedback: sensory substitution methods where the recorded stimulus is not only transferred to the amputee, but also translated to a different modality (modality-matched feedback), which transfers the stimulus without translation and direct neural stimulation, which interacts directly with peripheral afferent nerves. This paper presents an overview of the principal works and devices employed to provide upper limb amputees with sensory feedback. The focus is on sensory substitution and modality matched feedback; the principal features, advantages and disadvantages of the different methods are presented.

  5. Non-Traumatic Anterior Dislocation of a Total Knee Replacement Associated with Neurovascular Injury

    Science.gov (United States)

    Aderinto, Joseph; Gross, Allan E; Rittenhouse, Bryan

    2009-01-01

    Prosthetic total knee replacements rarely dislocate. When dislocation does occur, it is usually in a posterior direction in association with a posterior stabilised, cruciate-sacrificing prosthesis. Neurovascular injury is unusual. In this report, we describe a case of anterior dislocation of a cruciate-retaining total knee replacement in a 67-year-old woman. The dislocation occurred in the absence of overt trauma and resulted in severe neurovascular injury. PMID:19686618

  6. Loss of notochordal cell phenotype in 3D-cell cultures: implications for disc physiology and disc repair.

    Science.gov (United States)

    Omlor, G W; Nerlich, A G; Tirlapur, U K; Urban, J P; Guehring, T

    2014-12-01

    -culture caused a rapid loss of NC phenotype towards a CLC phenotype with disappearance of vacuoles, reduced cell size, increased proliferation, and gene-expression changes. These findings may be related to NC nutritional demands and support the latest hypothesis of NC maturation into CLC opposing the idea that NC get lost in human discs by cell death or apoptosis to be replaced by CLC from the inner annulus.

  7. Transcatheter aortic valve replacement

    Science.gov (United States)

    ... gov/ency/article/007684.htm Transcatheter aortic valve replacement To use the sharing features on this page, please enable JavaScript. Transcatheter aortic valve replacement (TAVR) is surgery to replace the aortic valve. ...

  8. Hip Replacement Surgery

    Science.gov (United States)

    ... Outreach Initiative Breadcrumb Home Health Topics English Español Hip Replacement Surgery Basics In-Depth Download Download EPUB ... PDF What is it? Points To Remember About Hip Replacement Surgery Hip replacement surgery removes damaged or ...

  9. Nicotine replacement therapy

    Science.gov (United States)

    Smoking cessation - nicotine replacement; Tobacco - nicotine replacement therapy ... Before you start using a nicotine replacement product, here are some things to know: The more cigarettes you smoke, the higher the dose you may need to ...

  10. Distraction of the temporomandibular joint condyle in patients with unilateral non-reducing disc displacement: Fact or fiction?

    Science.gov (United States)

    Yıldız, Melih; Çağatay Dayan, Süleyman; Şakar, Olcay; Sülün, Tonguç

    2017-07-24

    This study investigated the distractive effect of a unilateral pivot splint on patients with unilateral disc displacement without reduction. The study group was comprised of 18 patients who had no history of treatment with removable prosthetic restorations of molars, premolars, or canine teeth, and no previous treatment for temporomandibular disorder. Joint spaces measurements made on magnetic resonance images indicated the affected side to be narrower than the healthy side. Unilateral distraction splints were made for all patients. An ultrasonic motion analyzer was used to measure the vertical shift occurring on the affected side as patients closed their mouths with maximal force with the splint in their mouths. Closing with maximal force on the unilateral distraction splint led to a noticeable downward movement of the affected condyle. The findings of this study indicate that the TMJ condyle of patients with unilateral disc displacement without reduction may be unilaterally distracted if the articular space is narrowed.

  11. Local models of astrophysical discs

    Science.gov (United States)

    Latter, Henrik N.; Papaloizou, John

    2017-12-01

    Local models of gaseous accretion discs have been successfully employed for decades to describe an assortment of small-scale phenomena, from instabilities and turbulence, to dust dynamics and planet formation. For the most part, they have been derived in a physically motivated but essentially ad hoc fashion, with some of the mathematical assumptions never made explicit nor checked for consistency. This approach is susceptible to error, and it is easy to derive local models that support spurious instabilities or fail to conserve key quantities. In this paper we present rigorous derivations, based on an asympototic ordering, and formulate a hierarchy of local models (incompressible, Boussinesq and compressible), making clear which is best suited for a particular flow or phenomenon, while spelling out explicitly the assumptions and approximations of each. We also discuss the merits of the anelastic approximation, emphasizing that anelastic systems struggle to conserve energy unless strong restrictions are imposed on the flow. The problems encountered by the anelastic approximation are exacerbated by the disc's differential rotation, but also attend non-rotating systems such as stellar interiors. We conclude with a defence of local models and their continued utility in astrophysical research.

  12. Optic Disc Drusen in Children

    DEFF Research Database (Denmark)

    Malmqvist, Lasse; Li, Xiao Qiang; Eckmann, Christina L

    2017-01-01

    diameter and fetal birth and pubertal parameters are associated with the presence of ODD. METHODS: This observational, longitudinal population-based birth cohort study, with a nested case-control, included 1,406 children. Eye examinations were performed when the children were between 11 and 12 years of age....... Assessment was performed of optical coherence tomography (OCT) scans from 1,304 children with gradable enhanced depth imaging scans of the optic disc. RESULTS: ODD in one or both eyes were found in 13 (1.0%) of all children. All but one of the cases were found in children with scleral canal diameter...... in the lowest quartile (1,182-1,399 μm) in the nested case-control study. Children with ODD had a mean disc diameter of 1,339 μm (interquartile range, 30 μm), whereas it was 1,508 μm (interquartile range, 196 μm) in the 130 controls without ODD (P

  13. Acute failure of a St. Jude's prosthetic aortic valve: large pannus formation masked by a small thrombus.

    Science.gov (United States)

    Hurwitz, Seth Eric; Waxman, Daniel; Hecht, Susan

    2009-09-01

    Pannus formation and valve thrombus can cause prosthetic valve failure. The authors report the case of a 50-year-old woman who presented to the emergency room with decompensated heart failure secondary to mechanical valve dysfunction. On two-dimensional and transesophageal echocardiography, the patient had severe aortic stenosis and regurgitation. A thrombus seen on the valve was felt to be the etiology of her prosthetic valve failure. She underwent emergent cardiac surgery for aortic valve replacement. Pathology revealed that although a small thrombus was present, extensive pannus was the underlying mechanism of valve dysfunction. Differentiation between pannus and thrombus may have important clinical implications, but this case illustrates that distinguishing between these entities by echocardiographic and clinical criteria may not be possible.

  14. Minimum weight design of inhomogeneous rotating discs

    International Nuclear Information System (INIS)

    Jahed, Hamid; Farshi, Behrooz; Bidabadi, Jalal

    2005-01-01

    There are numerous applications for gas turbine discs in the aerospace industry such as in turbojet engines. These discs normally work under high temperatures while subjected to high angular velocities. Minimizing the weight of such items in aerospace applications results in benefits such as low dead weights and lower costs. High speed of rotation causes large centrifugal forces in a disc and simultaneous application of high temperatures reduces disc material strength. Thus, the latter effects tend to increase deformations of the disc under the applied loads. In order to obtain a reliable disc analysis and arrive at the corresponding correct stress distribution, solutions should consider changes in material properties due to the temperature field throughout the disc. To achieve this goal, an inhomogeneous disc model with variable thickness is considered. Using the variable material properties method, stresses are obtained for the disc under rotation and a steady temperature field. In this paper this is done by modelling the rotating disc as a series of rings of different but constant properties. The optimum disc profile is arrived at by sequentially proportioning the thicknesses of each ring to satisfy the stress requirements. This method vis-a-vis a mathematical programming procedure for optimization shows several advantages. Firstly, it is simple iterative proportioning in each design cycle not requiring involved mathematical operations. Secondly, due to its simplicity it alleviates the necessity of certain simplifications that are common in so-called rigorous mathematical procedures. The results obtained, compared to those published in the literature show agreement and superiority. A further advantage of the proposed method is the independence of the end results from the initially assumed point in the iterative design routine, unlike most methods published so far

  15. Prosthetic status and prosthetic need among the patients attending various dental institutes of ahmedabad and gandhinagar district, gujarat.

    Science.gov (United States)

    Shah, Vrinda R; Shah, Darshana N; Parmar, Chaitanya H

    2012-09-01

    The oral health being an integral part for the healthy living, necessity of disability limitation and rehabilitation in oral health has taken a paramount role. To assess the prosthetic status and to evaluate the prosthetic needs of the patients attending various institutes of Ahmedabad and Gandhinagar district. A total of 510 (264 males and 246 females) subjects at various dental institutes were examined in the study. A survey proforma was prepared with the help of WHO oral health assessment form (1997). Prosthetic status and prosthetic treatment need was recorded. Out of 510, any type of Edentulousness was 322 (63 %). Among them, 254 (49.8 %) were partially edentulous while 68 (13.3 %) were completely edentulous. Only 69 (13 %) were having any prosthesis in upper arch while only 80 (16 %) were having any prosthesis in lower arch. Need for any type of prosthesis in upper and lower arch was 55 and 60 % in males and females, respectively. In lower social class group need of prosthesis in upper and lower arch was 62 and 63 %, respectively. It was found that prosthetic status and prosthetic treatment need increased with increase in age. Steps should be taken to overcome this disparity and more emphasis should be given to meet the felt need of the people through government and non government organizations to improve the oral health. The unmet prosthetic treatment need should be met to rehabilitate needy people so that their disability may be limited.

  16. A Simulation Model of Focus and Radial Servos in Compact Disc Players with Disc Surface Defects

    DEFF Research Database (Denmark)

    Odgaard, Peter Fogh; Stoustrup, Jakob; Andersen, Palle

    2004-01-01

    Compact Disc players have been on the market in more than two decades.As a consequence most of the control servo problems have been solved. A large remaining problem to solve is the handling of Compact Discs with severe surface defects like scratches and fingerprints. This paper introduces a method...... for making the design of controllers handling surface defects easier. A simulation model of Compact Disc players playing discs with surface defects is presented. The main novel element in the model is a model of the surface defects. That model is based on data from discs with surface defects. This model...

  17. Intervertebral disc herniation: prevalence and association with ...

    African Journals Online (AJOL)

    Background: Low back pain is one of the common health problems encountered in life with intervertebral disc herniation being a common cause of its occurrence. Magnetic resonance imaging has emerged the gold standard for diagnosing a herniated disc. Aims and Objectives: To assess the frequency and pattern of ...

  18. The evolution of stellar exponential discs

    NARCIS (Netherlands)

    Ferguson, AMN; Clarke, CJ

    2001-01-01

    Models of disc galaxies which invoke viscosity-driven radial flows have long been known to provide a natural explanation for the origin of stellar exponential discs, under the assumption that the star formation and viscous time-scales are comparable. We present models which invoke simultaneous star

  19. Feature Based Control of Compact Disc Players

    DEFF Research Database (Denmark)

    Odgaard, Peter Fogh

    Two servo control loops are used to keep the Optical Pick-up Unit focused and radially on the information track of the Compact Disc. These control servos have problems handling surface faults on the Compact Disc. In this Ph.D thesis a method is proposed to improve the handling of these surface...

  20. Robust control of a compact disc mechanism

    NARCIS (Netherlands)

    Steinbuch, M.; Schootstra, G.; Bosgra, O.H.; Levine, W.S.

    1995-01-01

    A compact disc (CD) player is an optical decoding device that reproduces high-quality audio from a digitally coded signal recorded as a spiral-shaped track on a reflective disc. Apart from the audio application, other optical data systems (CD-ROM, optical data drive) and combined audio/video

  1. Computing Decoupled Residuals for Compact Disc Players

    DEFF Research Database (Denmark)

    Odgaard, Peter Fogh; Stoustrup, Jakob; Andersen, Palle

    2006-01-01

    a pair of residuals generated by Compact Disc Player. However, these residuals depend on the performance of position servos in the Compact Disc Player. In other publications of the same authors a pair of decoupled residuals is derived. However, the computation of these alternative residuals has been...

  2. Use NASA GES DISC Data in ArcGIS

    Science.gov (United States)

    Yang, Wenli; Pham, Long B.; Kempler, Steve

    2015-01-01

    This presentation describes GIS relevant data at NASA Goddard Earth Sciences Data and Information Services Center (GES DISC), GES DISC Services and Support for GIS Users, and use cases of GES DISC data in ArcGIS.

  3. Fixed prosthetic treatment in patients with cleft lip and palate

    Directory of Open Access Journals (Sweden)

    Bajevska Jagoda

    2017-01-01

    Full Text Available Introduction. The prosthetic treatment of patients with cleft palate includes various treatment options such as fixed partial dentures, removable partial prosthesis, etc. The type of prosthetic appliance is determined by the oral health of each individual and the circumstances. We presented three adult patients with the cleft lip and palate subjected to prosthetic treatment. Case report. From the possible prosthetic solutions according to the conditions in the oral cavity and the circumstances, fixed partial dentures veneered with composite or ceramic were chosen. A proper relationship between the teeth was reached with the fixed partial dentures, and function established, the phonetics improved and satisfying aesthetics effect accomplished improving the profile appearance of the patient’s face. Plastic surgery of the nose was performed after that. Conclusion. Multidisclipinary treatment is necessary for favourable long-term outcome in cleft lip and palate patients.

  4. The role of vision processing in prosthetic vision.

    Science.gov (United States)

    Barnes, Nick; He, Xuming; McCarthy, Chris; Horne, Lachlan; Kim, Junae; Scott, Adele; Lieby, Paulette

    2012-01-01

    Prosthetic vision provides vision which is reduced in resolution and dynamic range compared to normal human vision. This comes about both due to residual damage to the visual system from the condition that caused vision loss, and due to limitations of current technology. However, even with limitations, prosthetic vision may still be able to support functional performance which is sufficient for tasks which are key to restoring independent living and quality of life. Here vision processing can play a key role, ensuring that information which is critical to the performance of key tasks is available within the capability of the available prosthetic vision. In this paper, we frame vision processing for prosthetic vision, highlight some key areas which present problems in terms of quality of life, and present examples where vision processing can help achieve better outcomes.

  5. Antithrombotic Therapy in Patients with Prosthetic Heart Valves

    Directory of Open Access Journals (Sweden)

    Mohamed HA

    2009-01-01

    Full Text Available Patients with mechanical valve prostheses require a lifelong anticoagulant treatment. The combined use of Warfarin and low-dose aspirin appears to reduce the risk of valve thrombosis and systemic embolism at a low risk of bleeding. The management of women with prosthetic heart valves during pregnancy poses a particular challenge, as there are no available controlled clinical trials to provide guidelines for effective antithrombotic therapy. Oral anticoagulants, such as Warfarin, cause foetal embryopathy; unfractionated heparin and low-molecular-weight heparin have been reported to be ineffective in preventing thromboembolic complications.This article discusses the available data and the most recent guidelines in the antithrombotic management of patients with prosthetic valves, and antithrombotic therapy in various clinical situations such as pregnant women with prosthetic heart valves, and patients with prosthetic heart valves undergoing noncardiac surgery.

  6. Magnetic resonance imaging of intervertebral disc degeneration

    International Nuclear Information System (INIS)

    Maeda, Hiroshi; Noguchi, Masao; Kira, Hideaki; Fujiki, Hiroshi; Shimokawa, Isao; Hinoue, Kaichi.

    1993-01-01

    The aim of this study was to correlate the degree of lumbar intervertebral disc degeneration with findings of magnetic resonance imaging (MRI). Seventeen autopsied (from 7 patients) and 21 surgical (from 20 patients) intervertebral discs were used as specimens for histopathological examination. In addition, 21 intervertebral discs were examined on T2-weighted images. Histopathological findings from both autopsied and surgical specimens were well correlated with MRI findings. In particular, T2-weighted images reflected increased collagen fibers and rupture within the fibrous ring accurately. However, when severely degenerated intervertebral discs and hernia protruding the posterior longitudinal ligament existed, histological findings were not concordant well with T2-weighted images. Morphological appearances of autopsy specimens, divided into four on T2-weighted images, were well consistent with histological degeneration. This morphological classification, as shown on T2-weighted images, could also be used in the evaluation of intervertebral disc degeneration. (N.K.)

  7. Magnetic resonance imaging of intervertebral disc degeneration

    Energy Technology Data Exchange (ETDEWEB)

    Maeda, Hiroshi; Noguchi, Masao (Kitakyushu City Yahata Hospital, Fukuoka (Japan)); Kira, Hideaki; Fujiki, Hiroshi; Shimokawa, Isao; Hinoue, Kaichi

    1993-02-01

    The aim of this study was to correlate the degree of lumbar intervertebral disc degeneration with findings of magnetic resonance imaging (MRI). Seventeen autopsied (from 7 patients) and 21 surgical (from 20 patients) intervertebral discs were used as specimens for histopathological examination. In addition, 21 intervertebral discs were examined on T2-weighted images. Histopathological findings from both autopsied and surgical specimens were well correlated with MRI findings. In particular, T2-weighted images reflected increased collagen fibers and rupture within the fibrous ring accurately. However, when severely degenerated intervertebral discs and hernia protruding the posterior longitudinal ligament existed, histological findings were not concordant well with T2-weighted images. Morphological appearances of autopsy specimens, divided into four on T2-weighted images, were well consistent with histological degeneration. This morphological classification, as shown on T2-weighted images, could also be used in the evaluation of intervertebral disc degeneration. (N.K.).

  8. The formation of planets by disc fragmentation

    Directory of Open Access Journals (Sweden)

    Stamatellos Dimitris

    2013-04-01

    Full Text Available I discuss the role that disc fragmentation plays in the formation of gas giant and terrestrial planets, and how this relates to the formation of brown dwarfs and low-mass stars, and ultimately to the process of star formation. Protostellar discs may fragment, if they are massive enough and can cool fast enough, but most of the objects that form by fragmentation are brown dwarfs. It may be possible that planets also form, if the mass growth of a proto-fragment is stopped (e.g. if this fragment is ejected from the disc, or suppressed and even reversed (e.g by tidal stripping. I will discuss if it is possible to distinguish whether a planet has formed by disc fragmentation or core accretion, and mention of a few examples of observed exoplanets that are suggestive of formation by disc fragmentation.

  9. T1 hyperintense disc in alkaptonuria.

    Science.gov (United States)

    Sag, Alan A; Silbergleit, Richard; Olson, Rick E; Wilson, Jon; Krishnan, Anant

    2012-10-01

    Case report. To report a rare case of alkaptonuria presenting as a T1-hyperintense disc herniation. A 46-year-old man without previous diagnosis of alkaptonuria underwent evaluation for progressive back pain revealing a T1-hyperintense disc herniation at the L3-L4 level. Discectomy recovered a blackened disc that was pathologically confirmed to be nucleus pulposus with alkaptonuric involvement. The differential diagnosis of a T1-hyperintense, T2-hypointense disc on magnetic resonance imaging is discussed, with emphasis on the pathophysiology of alkaptonuria. A single patient is reported. Pathologically proven patient presentation with radiological and pathological images. We report a rare case of alkaptonuria presenting as a T1-hyperintense disc herniation.

  10. Nonconventional mesocaval prosthetic shunt interposition in ...

    African Journals Online (AJOL)

    years demonstrates shunt patency and normal development ... However, the child's condition and growth ... The child has satisfactory weight and growth gain. (40kg .... infants and toddlers: replacement with decellularized branched pulmonary.

  11. Periprosthetic fracture-dislocation in a loosened total knee replacement treated by knee arthrodesis

    International Nuclear Information System (INIS)

    Lozano Moreno, Francisco Jose

    2004-01-01

    We present a patient who was operated four years before performing a total knee replacement. She fell down resulting a periprosthetic femoral fracture and a prosthetic dislocation. After evaluating different treatments, we decided to do prosthetic removal and a knee arthrodesis using an intramedullar nail. The femoral fracture was fixed with wire cerclages. Knee arthrodesis is a procedure uses as a last option for the treatment of infected or loosed arthroplasties. In our case it was difficult to consider any other reconstructive procedure due to the association of fracture, dislocation and loosening. The evolution has been satisfactory with good functional result and without pain

  12. Custom-made laser-welded titanium implant prosthetic abutment.

    Science.gov (United States)

    Iglesia-Puig, Miguel A

    2005-10-01

    A technique to create an individually modified implant prosthetic abutment is described. An overcasting is waxed onto a machined titanium abutment, cast in titanium, and joined to it with laser welding. With the proposed technique, a custom-made titanium implant prosthetic abutment is created with adequate volume and contour of metal to support a screw-retained, metal-ceramic implant-supported crown.

  13. ORAL HYGIENE OF PROSTHETIC DENTURE USER IN KODINGARENG ISLAND

    OpenAIRE

    NUR, NURUL KUSUMADEWI S.KG

    2008-01-01

    Objectives:to determine the level of oral hygiene for prosthetic denture user, especially for full-denture in Kodingareng Island. This researchincluded the distribution level of prosthetic denture user based on age and education.Methods: the method that used in this research is observational descriptive withcross sectional-studyas the research design. Variable result of the research determined in to 3, those are bad, middle, and good. Result:the highest percentage o...

  14. Defining line replaceable units

    NARCIS (Netherlands)

    Parada Puig, J. E.; Basten, R. J I

    2015-01-01

    Defective capital assets may be quickly restored to their operational condition by replacing the item that has failed. The item that is replaced is called the Line Replaceable Unit (LRU), and the so-called LRU definition problem is the problem of deciding on which item to replace upon each type of

  15. Prosthetic Status and Prosthetic Need Among the Patients Attending Various Dental Institutes of Ahmedabad and Gandhinagar District, Gujarat

    OpenAIRE

    Shah, Vrinda R.; Shah, Darshana N.; Parmar, Chaitanya H.

    2012-01-01

    The oral health being an integral part for the healthy living, necessity of disability limitation and rehabilitation in oral health has taken a paramount role. To assess the prosthetic status and to evaluate the prosthetic needs of the patients attending various institutes of Ahmedabad and Gandhinagar district. A total of 510 (264 males and 246 females) subjects at various dental institutes were examined in the study. A survey proforma was prepared with the help of WHO oral health assessment ...

  16. Antibiotic prophylaxis for dental treatment after prosthetic joint replacement: exploring the orthopaedic surgeon's opinion

    Directory of Open Access Journals (Sweden)

    Clare M. McNally, MPhil(Dent

    2016-09-01

    Conclusions: Australian orthopaedic surgeons continue to recommend antibiotic prophylaxis for dental treatment. The recording of PJI in relation to dental procedures into clinical registries would enable the development of consistent guidelines between professional groups responsible for the care of this patient group.

  17. Intervertebral Disc Characteristic on Progressive Neurological Deficit

    Directory of Open Access Journals (Sweden)

    Farid Yudoyono

    2017-09-01

    Full Text Available Objective: To examine the intervertebral disc characteristic on magnetic resonance imaging (MRI in lumbar herniated disc (LHD patients with progressive neurological deficit. Methods: Patients were collected retrospectively from Dr. Hasan Sadikin General Hospital Database from 2011–2013 with LHD, had neurological deficit such as radiculopathy and cauda equine syndrome for less than four weeks with a positive sign confirmed by neurological examination and confirmatory with MRI examination. Results: A total of 14 patients with lumbar herniated disc disease (10 males, 4 females suffered from progressive neurological deficit with an average age of (52.07±10.9 years old. Early disc height was 9.38±0.5 mm and progressive neurological deficit state disc height was 4.03±0.53 mm, which were significantly different statisticaly (p<0.01. Symptoms of radiculopathy were seen in 11 patients and cauda equine syndrome in three patients. Modic changes grade 1 was found in five patients, grade 2 in eight patients,grade 3 in one patient, Pfirmman grade 2 in eleven patients and grade 3 in three patients. Thecal sac compression 1/3 compression was seen in four patients and 2/3 compression in ten patients. Conclusions: Neurosurgeon should raise concerns on the characteristic changes of intervertebral disc in magnetic resonance imaging examination to avoid further neural injury in lumbar herniated disc patients.

  18. Deep-down ionization of protoplanetary discs

    Science.gov (United States)

    Glassgold, A. E.; Lizano, S.; Galli, D.

    2017-12-01

    The possible occurrence of dead zones in protoplanetary discs subject to the magneto-rotational instability highlights the importance of disc ionization. We present a closed-form theory for the deep-down ionization by X-rays at depths below the disc surface dominated by far-ultraviolet radiation. Simple analytic solutions are given for the major ion classes, electrons, atomic ions, molecular ions and negatively charged grains. In addition to the formation of molecular ions by X-ray ionization of H2 and their destruction by dissociative recombination, several key processes that operate in this region are included, e.g. charge exchange of molecular ions and neutral atoms and destruction of ions by grains. Over much of the inner disc, the vertical decrease in ionization with depth into the disc is described by simple power laws, which can easily be included in more detailed modelling of magnetized discs. The new ionization theory is used to illustrate the non-ideal magnetohydrodynamic effects of Ohmic, Hall and Ambipolar diffusion for a magnetic model of a T Tauri star disc using the appropriate Elsasser numbers.

  19. Consumer design priorities for upper limb prosthetics.

    Science.gov (United States)

    Biddiss, Elaine; Beaton, Dorcas; Chau, Tom

    2007-11-01

    To measure consumer satisfaction with upper limb prosthetics and provide an enumerated list of design priorities for future developments. A self-administered, anonymous survey collected information on participant demographics, history of and goals for prosthesis use, satisfaction, and design priorities. The questionnaire was available online and in paper format and was distributed through healthcare providers, community support groups, and one prosthesis manufacturer; 242 participants of all ages and levels of upper limb absence completed the survey. Rates of rejection for myoelectric hands, passive hands, and body-powered hooks were 39%, 53%, and 50%, respectively. Prosthesis wearers were generally satisfied with their devices while prosthesis rejecters were dissatisfied. Reduced prosthesis weight emerged as the highest priority design concern of consumers. Lower cost ranked within the top five design priorities for adult wearers of all device types. Life-like appearance is a priority for passive/cosmetic prostheses, while improved harness comfort, wrist movement, grip control and strength are required for body-powered devices. Glove durability, lack of sensory feedback, and poor dexterity were also identified as design priorities for electric devices. Design priorities reflect consumer goals for prosthesis use and vary depending on the type of prosthesis used and age. Future design efforts should focus on the development of more light-weight, comfortable prostheses.

  20. Analytical Study of Active Prosthetic Legs

    Science.gov (United States)

    Ono, Kyosuke; Katsumata, Mie

    Walking with prosthesis has not been well analyzed mathematically and it seems that the design of powered prosthesis has been done empirically so far. This paper presents a dynamic simulation of a normal human walking and walking with an active prosthesis. We also studied the two controlling methods of a powered thigh prosthesis based on multi-body simulation of human walking. First we measured the normal human walking gait, then, we showed that a 3-DOF human walking model can walk on level ground by applying tracking control to the measured walking gait within a certain range of tuned walking period. Next, we applied the tracking control and self-excited control to the powered thigh prosthesis and compared the robustness and efficiency of the two control methods by numerical simulation. As a result, we found that the self-excited control can significantly decrease the hip joint torque and specific cost to 1/3 compared with the tracking control. Moreover, the self-excited control is superior to the tracking control because tuning for the walking period is not needed for the active prosthetic leg.

  1. Surface EMG in advanced hand prosthetics.

    Science.gov (United States)

    Castellini, Claudio; van der Smagt, Patrick

    2009-01-01

    One of the major problems when dealing with highly dexterous, active hand prostheses is their control by the patient wearing them. With the advances in mechatronics, building prosthetic hands with multiple active degrees of freedom is realisable, but actively controlling the position and especially the exerted force of each finger cannot yet be done naturally. This paper deals with advanced robotic hand control via surface electromyography. Building upon recent results, we show that machine learning, together with a simple downsampling algorithm, can be effectively used to control on-line, in real time, finger position as well as finger force of a highly dexterous robotic hand. The system determines the type of grasp a human subject is willing to use, and the required amount of force involved, with a high degree of accuracy. This represents a remarkable improvement with respect to the state-of-the-art of feed-forward control of dexterous mechanical hands, and opens up a scenario in which amputees will be able to control hand prostheses in a much finer way than it has so far been possible.

  2. Peri-prosthetic fracture vibration testing

    Energy Technology Data Exchange (ETDEWEB)

    Cruce, Jesse R [Los Alamos National Laboratory; Erwin, Jenny R [Los Alamos National Laboratory; Remick, Kevin R [Los Alamos National Laboratory; Cornwell, Phillip J [Los Alamos National Laboratory; Menegini, R. Michael [INDIANA UNIV.; Racanelli, Joe [STRYKER ORTHOPARDICS

    2010-11-08

    The purpose of this study was to establish a test setup and vibration analysis method to predict femoral stem seating and prevent bone fracture using accelerometer and force response data from an instrumented stem and impactor. This study builds upon earlier studies to identify a means to supplement a surgeon's tactile and auditory senses by using damage identification techniques normally used for civil and mechanical structures. Testing was conducted using foam cortical shell sawbones prepared for stems of different geometries. Each stem was instrumented with an accelerometer. Two impactor designs were compared: a monolithic impactor and a two-piece impactor, each with an integrated load cell and accelerometer. Acceleration and force measurements were taken in the direction of impaction. Comparisons between different methods of applying an impacting force were made, including a drop tower and a surgical hammer. The effect of varying compliance on the data was also investigated. The ultimate goal of this study was to assist in the design of an integrated portable data acquisition system capable of being used in future cadaveric testing. This paper will discuss the experimental setup and the subsequent results of the comparisons made between impactors, prosthetic geometries, compliances, and impact methods. The results of this study can be used for both future replicate testing as well as in a cadaveric environment.

  3. Rare early prosthesis obstruction after mitral valve replacement: a case report and literature review

    Directory of Open Access Journals (Sweden)

    Shi Jun

    2012-07-01

    Full Text Available Abstract As a dreadful complication after the mechanical heart valve replacement, prosthetic valve obstruction caused by pannus formation occurs increasingly with time. The authors here present a case of 42-year-old woman who was urgently admitted to hospital with acute heart failure symptoms due to the mechanical mitral valve failure only 3 months after surgery. Transthoracic and transesophageal echocardiography demonstrated that the bileaflet of the mitral prosthesis were completely immobilized with only a small transvalvular jet remained. During the reoperation, the reason of the prosthetic valve obstruction was attributed to the noncircular pannus ingrowth extending from the atrioventricular side. For a better understanding of the prosthetic valve dysfunction caused by pannus formation, the authors then compile a literature review to briefly discuss the status quo of the clinical characteristics of this uncommon complication.

  4. FEM and Von Mises Analysis on Prosthetic Crowns Structural Elements: Evaluation of Different Applied Materials

    Directory of Open Access Journals (Sweden)

    Ennio Bramanti

    2017-01-01

    Full Text Available The aim of this paper is to underline the mechanical properties of dental single crown prosthodontics materials in order to differentiate the possibility of using each material for typical clinical condition and masticatory load. Objective of the investigation is to highlight the stress distribution over different common dental crowns by using computer-aided design software and a three-dimensional virtual model. By using engineering systems of analyses like FEM and Von Mises investigations it has been highlighted the strength over simulated lower first premolar crowns made by chrome cobalt alloy, golden alloy, dental resin, and zirconia. The prosthodontics crown models have been created and put on simulated chewing stresses. The three-dimensional models were subjected to axial and oblique forces and both guaranteed expected results over simulated masticatory cycle. Dental resin presented the low value of fracture while high values have been recorded for the metal alloy and zirconia. Clinicians should choose the better prosthetic solution for the teeth they want to restore and replace. Both prosthetic dental crowns offer long-term success if applied following the manufacture guide limitations and suggestions.

  5. FEM and Von Mises Analysis on Prosthetic Crowns Structural Elements: Evaluation of Different Applied Materials.

    Science.gov (United States)

    Bramanti, Ennio; Cervino, Gabriele; Lauritano, Floriana; Fiorillo, Luca; D'Amico, Cesare; Sambataro, Sergio; Denaro, Deborah; Famà, Fausto; Ierardo, Gaetano; Polimeni, Antonella; Cicciù, Marco

    2017-01-01

    The aim of this paper is to underline the mechanical properties of dental single crown prosthodontics materials in order to differentiate the possibility of using each material for typical clinical condition and masticatory load. Objective of the investigation is to highlight the stress distribution over different common dental crowns by using computer-aided design software and a three-dimensional virtual model. By using engineering systems of analyses like FEM and Von Mises investigations it has been highlighted the strength over simulated lower first premolar crowns made by chrome cobalt alloy, golden alloy, dental resin, and zirconia. The prosthodontics crown models have been created and put on simulated chewing stresses. The three-dimensional models were subjected to axial and oblique forces and both guaranteed expected results over simulated masticatory cycle. Dental resin presented the low value of fracture while high values have been recorded for the metal alloy and zirconia. Clinicians should choose the better prosthetic solution for the teeth they want to restore and replace. Both prosthetic dental crowns offer long-term success if applied following the manufacture guide limitations and suggestions.

  6. Simulation of personalised haemodynamics by various mounting positions of a prosthetic valve using computational fluid dynamics.

    Science.gov (United States)

    Bongert, Markus; Geller, Marius; Pennekamp, Werner; Nicolas, Volkmar

    2018-03-03

    Diseases of the cardiovascular system account for nearly 42% of all deaths in the European Union. In Germany, approximately 12,000 patients receive surgical replacement of the aortic valve due to heart valve disease alone each year. A three-dimensional (3D) numerical model based on patient-specific anatomy derived from four-dimensional (4D) magnetic resonance imaging (MRI) data was developed to investigate preoperatively the flow-induced impact of mounting positions of aortic prosthetic valves to select the best orientation for individual patients. Systematic steady-state analysis of blood flow for different rotational mounting positions of the valve is only possible using a virtual patient model. A maximum velocity of 1 m/s was used as an inlet boundary condition, because the opening angle of the valve is at its largest at this velocity. For a comparative serial examination, it is important to define the standardised general requirements to avoid impacts other than the rotated implantation of the prosthetic aortic valve. In this study, a uniform velocity profile at the inlet for the inflow of the aortic valve and the real aortic anatomy were chosen for all simulations. An iterative process, with the weighted parameters flow resistance (1), shear stress (2) and velocity (3), was necessary to determine the best rotated orientation. Blood flow was optimal at a 45° rotation from the standard implantation orientation, which will offer a supply to the coronary arteries.

  7. Prosthetic valve endocarditis 7 months after transcatheter aortic valve implantation diagnosed with 3D TEE.

    Science.gov (United States)

    Sarı, Cenk; Durmaz, Tahir; Karaduman, Bilge Duran; Keleş, Telat; Bayram, Hüseyin; Baştuğ, Serdal; Özen, Mehmet Burak; Bayram, Nihal Akar; Bilen, Emine; Ayhan, Hüseyin; Kasapkara, Hacı Ahmet; Bozkurt, Engin

    2016-01-01

    Transcatheter aortic valve implantation (TAVI) was introduced as an alternative treatment for patients with severe symptomatic aortic stenosis for whom surgery would be high-risk. Prosthetic aortic valve endocarditis is a serious complication of surgical AVR (SAVR) with high morbidity and mortality. According to recent cases, post-TAVI prosthetic valve endocarditis (PVE) seems to occur very rarely. We present the case of a 75-year-old woman who underwent TAVI (Edwards Saphien XT) with an uneventful postoperative stay. She was diagnosed with endocarditis using three dimensional (3D) echocardiography on the TAVI device 7 months later and she subsequently underwent surgical aortic valve replacement. Little experience of the interpretation of transoesophageal echocardiography (TEE) and the clinical course and effectiveness of treatment strategies in post-TAVI endocarditis exists. We report a case of PVE in a TAVI patient which was diagnosed with three-dimensional transoesophageal echocardiography (3DTEE). Copyright © 2016 Hellenic Cardiological Society. Published by Elsevier B.V. All rights reserved.

  8. Likelihood inference for unions of interacting discs

    DEFF Research Database (Denmark)

    Møller, Jesper; Helisova, K.

    2010-01-01

    This is probably the first paper which discusses likelihood inference for a random set using a germ-grain model, where the individual grains are unobservable, edge effects occur and other complications appear. We consider the case where the grains form a disc process modelled by a marked point...... process, where the germs are the centres and the marks are the associated radii of the discs. We propose to use a recent parametric class of interacting disc process models, where the minimal sufficient statistic depends on various geometric properties of the random set, and the density is specified......-based maximum likelihood inference and the effect of specifying different reference Poisson models....

  9. Spectroscopic Parameters of Lumbar Intervertebral Disc Material

    Science.gov (United States)

    Terbetas, G.; Kozlovskaja, A.; Varanius, D.; Graziene, V.; Vaitkus, J.; Vaitkuviene, A.

    2009-06-01

    There are numerous methods of investigating intervertebral disc. Visualization methods are widely used in clinical practice. Histological, imunohistochemical and biochemical methods are more used in scientific research. We propose that a new spectroscopic investigation would be useful in determining intervertebral disc material, especially when no histological specimens are available. Purpose: to determine spectroscopic parameters of intervertebral disc material; to determine emission spectra common for all intervertebral discs; to create a background for further spectroscopic investigation where no histological specimen will be available. Material and Methods: 20 patients, 68 frozen sections of 20 μm thickness from operatively removed intervertebral disc hernia were excited by Nd:YAG microlaser STA-01-TH third harmonic 355 nm light throw 0, 1 mm fiber. Spectrophotometer OceanOptics USB2000 was used for spectra collection. Mathematical analysis of spectra was performed by ORIGIN multiple Gaussian peaks analysis. Results: In each specimen of disc hernia were found distinct maximal spectral peaks of 4 types supporting the histological evaluation of mixture content of the hernia. Fluorescence in the spectral regions 370-700 nm was detected in the disc hernias. The main spectral component was at 494 nm and the contribution of the components with the peak wavelength values at 388 nm, 412 nm and 435±5 nm were varying in the different groups of samples. In comparison to average spectrum of all cases, there are 4 groups of different spectral signatures in the region 400-500 nm in the patient groups, supporting a clinical data on different clinical features of the patients. Discussion and Conclusion: besides the classical open discectomy, new minimally invasive techniques of treating intervertebral disc emerge (PLDD). Intervertebral disc in these techniques is assessed by needle, no histological specimen is taken. Spectroscopic investigation via fiber optics through the

  10. 100 top-cited scientific papers in limb prosthetics.

    Science.gov (United States)

    Eshraghi, Arezoo; Osman, Noor Azuan Abu; Gholizadeh, Hossein; Ali, Sadeeq; Shadgan, Babak

    2013-11-17

    Research has tremendously contributed to the developments in both practical and fundamental aspects of limb prosthetics. These advancements are reflected in scientific articles, particularly in the most cited papers. This article aimed to identify the 100 top-cited articles in the field of limb prosthetics and to investigate their main characteristics. Articles related to the field of limb prosthetics and published in the Web of Knowledge database of the Institute for Scientific Information (ISI) from the period of 1980 to 2012. The 100 most cited articles in limb prosthetics were selected based on the citation index report. All types of articles except for proceedings and letters were included in the study. The study design and level of evidence were determined using Sackett's initial rules of evidence. The level of evidence was categorized either as a systematic review or meta-analysis, randomized controlled trial, cohort study, case-control study, case series, expert opinion, or design and development. The top cited articles in prosthetics were published from 1980 to 2012 with a citation range of 11 to 90 times since publication. The mean citation rate was 24.43 (SD 16.7) times. Eighty-four percent of the articles were original publications and were most commonly prospective (76%) and case series studies (67%) that used human subjects (96%) providing level 4 evidence. Among the various fields, rehabilitation (47%), orthopedics (29%), and sport sciences (28%) were the most common fields of study. The study established that studies conducted in North America and were written in English had the highest citations. Top cited articles primarily dealt with lower limb prosthetics, specifically, on transtibial and transradial prosthetic limbs. Majority of the articles were experimental studies.

  11. Chiropractic management of patients post-disc arthroplasty: eight case reports

    Directory of Open Access Journals (Sweden)

    Descarreaux Martin

    2010-04-01

    Full Text Available Abstract Background When conservative therapies for low back pain (LBP are not effective, elective surgery may be proposed to these patients. Over the last 20 years, a new technology, disc replacement, has become increasingly popular because it is believed to maintain or restore the integrity of spinal movement and minimize the side-effects compared to fusion. Although disc replacement may relieve a patient from pain and related disability, soreness and stiffness of the lumbopelvic region seem to be common aftermaths of the surgery. This prospective case series was undertaken to identify and describe potential adverse events of lumbar spinal manipulation, a common therapy for low back pain, in a group of patients with symptoms after disc prostheses. Cases presentation Eight patients who underwent lumbar spine total disc replacement were referred by an orthopaedic surgeon for chiropractic treatments. These patients had 1 or 2 total lumbar disc replacements and were considered stable according to the surgical protocol but presented persistent, post-surgical, non-specific LBP or pelvic pain. They were treated with lumbar spine side posture manipulations only and received 8 to 10 chiropractic treatments based on the clinical evolution and the chiropractor's judgment. Outcome measures included benign, self-limiting, and serious adverse events after low back spinal manipulative therapy. The Oswestry Disability Index, a pain scale and the fear avoidance belief questionnaire were administered to respectively assess disability, pain and fear avoidance belief about work and physical activity. This prospective case series comprised 8 patients who all had at least 1 total disc replacement at the L4/L5 or L5/S1 level and described persistent post-surgical LBP interfering with their daily activities. Commonly-reported side-effects of a benign nature included increased pain and/or stiffness of short duration in nearly half of the chiropractic treatment period

  12. Special features of total knee replacement in hemophilia.

    Science.gov (United States)

    Rodriguez-Merchan, Emerito Carlos

    2013-12-01

    Total knee replacement is an operation frequently needed by hemophilia patients, which greatly improves their quality of life. This operation, however, carries a higher risk of bleeding and infection for hemophiliacs than it does for osteoarthritis sufferers. It is advisable to implant prosthetic components using antibiotic-loaded cement. It is essential to maintain a level of 100% of the replacement clotting factor for 2 weeks. Hematological treatment must be established, depending on the patient's factor levels and other pharmacokinetic parameters such as recovery and half-life, optimal doses and treatment time. It is preferable to use general anesthesia due to the risk of spinal bleeding. The lifespan of total knee replacement in hemophilic patients is shorter than in patients with osteoarthritis because of the increased risk of infection.

  13. Thermal analysis on motorcycle disc brake geometry

    Science.gov (United States)

    W. M. Zurin W., S.; Talib, R. J.; Ismail, N. I.

    2017-08-01

    Braking is a phase of slowing and stop the movement of motorcycle. During braking, the frictional heat was generated and the energy was ideally should be faster dissipated to surrounding to prevent the built up of the excessive temperature which may lead to brake fluid vaporization, thermoelastic deformation at the contact surface, material degradation and failure. In this paper, solid and ventilated type of motorcycle disc brake are being analyse using Computational Fluid Dynamic (CFD) software. The main focus of the analysis is the thermal behaviour during braking for solid and ventilated disc brake. A comparison between both geometries is being discussed to determine the better braking performance in term of temperature distribution. It is found that ventilated disc brake is having better braking performance in terms of heat transfer compare to solid disc.

  14. Hydrodynamic forces on two moving discs

    Directory of Open Access Journals (Sweden)

    Burton D.A.

    2004-01-01

    Full Text Available We give a detailed presentation of a flexible method for constructing explicit expressions of irrotational and incompressible fluid flows around two rigid circular moving discs. We also discuss how such expressions can be used to compute the fluid-induced forces and torques on the discs in terms of Killing drives. Conformal mapping techniques are used to identify a meromorphic function on an annular region in C with a flow around two circular discs by a Mobius transformation. First order poles in the annular region correspond to vortices outside of the two discs. Inflows are incorporated by putting a second order pole at the point in the annulus that corresponds to infinity.

  15. Locally prepared antibiotic sensitivity discs: a substitute for imported ...

    African Journals Online (AJOL)

    Zones of inhibition were compared with those obtained from commercial antibiotic discs. Results obtained showed that discs prepared locally from antibiotic tablets, performed comparably with commercially obtained discs. There was no significant statistical difference between the two tested discs. We therefore recommend ...

  16. Ankle replacement - discharge

    Science.gov (United States)

    ... total - discharge; Total ankle arthroplasty - discharge; Endoprosthetic ankle replacement - discharge; Osteoarthritis - ankle ... You had an ankle replacement. Your surgeon removed and reshaped ... an artificial ankle joint. You received pain medicine and were ...

  17. Partial knee replacement - slideshow

    Science.gov (United States)

    ... page: //medlineplus.gov/ency/presentations/100225.htm Partial knee replacement - series—Normal anatomy To use the sharing ... A.M. Editorial team. Related MedlinePlus Health Topics Knee Replacement A.D.A.M., Inc. is accredited ...

  18. Prosthetic rehabilitation of severe Siebert′s Class III defect with modified Andrews bridge system

    Directory of Open Access Journals (Sweden)

    Manu Rathee

    2015-01-01

    Full Text Available Prosthetic dentistry involves the replacement of missing and contiguous tissues with artificial substitutes to restore and maintain the oral functions, appearance, and health of the patient. The treatment of edentulous areas with ridge defects poses a challenging task for the dentist. Management of such cases involves a wide range of treatment options comprising mainly of surgical interventions and non surgical techniques such as use of removable, fixed or fixed- removable partial dentures. But each treatment plan undertaken should be customized according to patient needs. A variety of factors such as quality and quantity of existing contiguous hard and soft tissues, systemic condition and economic status of the patient play an important role in treatment planning, clinical outcome and prognosis. This case report presents the restoration of a Seibert′s Class III ridge defect by an economical modification of Andrews Bridge in a 32 Year old patient.

  19. Maximizing prosthetic valve size with the Top Hat supra-annular aortic valve

    DEFF Research Database (Denmark)

    Aagaard, Jan; Geha, Alexander S.

    2007-01-01

    BACKGROUND AND AIM OF THE STUDY: The CarboMedics Top Hat supra-annular aortic valve allows a one-size (and often two-size) increase over the standard intra-annular valve. This advantage should minimize the risk of patient-prosthesis mismatch, where the effective prosthetic valve orifice area....... This study evaluates the authors' clinical experience with Top Hat supra-annular aortic valve size selection, and the technical aspects of implantation. METHODS: Between January 1999 and October 2005, a total of 251 consecutive patients underwent 252 aortic valve replacements with Top Hat supra...... required unplanned coronary bypass, and 30-day mortality was 2.0% (5/251), indicating a good safety profile for the valves implanted in this series. CONCLUSION: The general distribution of implant sizes in the US indicates that cardiac surgeons may be under-sizing the Top Hat supra-annular aortic valve...

  20. Optic Disc Pit with Sectorial Retinitis Pigmentosa

    OpenAIRE

    Balikoglu-Yilmaz, Melike; Taskapili, Muhittin; Yilmaz, Tolga; Teke, Mehmet Yasin

    2013-01-01

    Sectorial retinitis pigmentosa (RP) and optic disc pit (ODP) are rare clinical conditions. We present a 40-year-old woman with a history of mild night blindness and decreased vision in the right eye for about 5 years. Fundus examination revealed retinal pigmentary changes in the superior and inferotemporal sectors covering the macula and reduced arterial calibre and ODP at the temporal edge of the optic disc. In addition, fundus autofluorescence, spectral-domain optical coherence tomography, ...

  1. The lowest surface brightness disc galaxy known

    International Nuclear Information System (INIS)

    Davies, J.I.; Phillipps, S.; Disney, M.J.

    1988-01-01

    The discovery of a galaxy with a prominent bulge and a dominant extremely low surface brightness disc component is reported. The profile of this galaxy is very similar to the recently discovered giant low surface brightness galaxy Malin 1. The disc central surface brightness is found to be ∼ 26.4 Rμ, some 1.5 mag fainter than Malin 1 and thus by far the lowest yet observed. (author)

  2. Spontaneous Resolution of Optic Disc Pit Maculopathy

    OpenAIRE

    Tripathy, Koushik

    2017-01-01

    I read with interest the article reporting spontaneous resolution of optic disc pit maculopathy in a boy.1 Though the presence of an optic disc pit and associated macular involvement is undoubted in the presented case, the provided optical coherence tomography (OCT) does not clearly show typical intraretinal schisis (Figure 1B)1 at multiple retinal levels which may communicate with the pit. Instead, it shows a sub-internal limiting membrane (sub-ILM) cavity. Such cavities are known to occur f...

  3. Prosthetic implant treatment of the edentulous maxilla with overdenture.

    Science.gov (United States)

    Inversini, M

    2006-10-01

    The literature concerning the success of prosthetic implant treatment with maxillary overdenture is reviewed, and variables affecting treatment from the implant and prosthetic standpoint are analysed. Guidelines for the fabrication of maxillary overimplants comparable to those for mandibular overimplants are still lacking, as are evidence-based prosthetic design concepts. Individual methods and techniques have been described, but evaluation standards for the outcome of maxillary prosthetic-implant treatment are lacking or individually interpreted. The biomechanics involved in the proposed system are described, together with the advantages of telescopic crowns for the retention of removable partial prosthesis supported by maxillary implants. The positive influence, in terms of long-term prognosis, of the perio-protective design of removable partial prostheses supported by maxillary overimplants is also discussed. The proposed system not only provides stability, support and retention for removable partial prostheses supported by maxillary implants, but also enables implant survival rates to be improved, both for biomechanical reasons and due to improved oral hygiene. The simplification of fabrication procedures, repair, rebasing and re-operating also reduce the cost of follow-up and improve the cost/benefit ratio. However, additional studies are needed to clarify the number and most appropriate distribution of implants, as well as the most favourable prosthetic designs for maxillary overimplants.

  4. Provision of Prosthetic Services Following Lower Limb Amputation in Malaysia

    Science.gov (United States)

    Arifin, Nooranida; Hasbollah, Hasif Rafidee; Hanafi, Muhammad Hafiz; Ibrahim, Al Hafiz; Rahman, Wan Afezah Wan Abdul; Aziz, Roslizawati Che

    2017-01-01

    The incidence of lower limb amputation is high across the globe and continues to be a major threat to morbidity and mortality. Consequently, the provision of high quality and effective prosthetics services have been known as an essential component for a successful rehabilitation outcome. In Malaysia, amputation prevalence has been increasing in which several main components of service delivering aspects (such as service intervention, prosthetic personnel) should be anticipated to accommodate for the increasing demand. This article highlights the hurdles experienced in providing prosthetic services in Malaysia from multiple aspects such as financial burden to acquire the prosthesis and lack of expertise to produce quality prosthesis. This paramount issues consequently justify for the urgency to carry out national level survey on the current statistics of lower limb amputation and to ascertain the available workforce to provide a quality prosthetics services. Only with accurate and current information from the national survey, strategies and policies aimed at enhancing the outcome from prosthetics services can be achieved. PMID:29386978

  5. Archival-grade optical disc design and international standards

    Science.gov (United States)

    Fujii, Toru; Kojyo, Shinichi; Endo, Akihisa; Kodaira, Takuo; Mori, Fumi; Shimizu, Atsuo

    2015-09-01

    Optical discs currently on the market exhibit large variations in life span among discs, making them unsuitable for certain business applications. To assess and potentially mitigate this problem, we performed accelerated degradation testing under standard ISO conditions, determined the probable disc failure mechanisms, and identified the essential criteria necessary for a stable disc composition. With these criteria as necessary conditions, we analyzed the physical and chemical changes that occur in the disc components, on the basis of which we determined technological measures to reduce these degradation processes. By applying these measures to disc fabrication, we were able to develop highly stable optical discs.

  6. Lições sobre a substituição total de disco cervical após sete anos de acompanhamento Lecciones sobre el reemplazo total de disco cervical después de siete años de seguimiento Lessons learned on cervical total disc replacement after 7-year follow-up

    Directory of Open Access Journals (Sweden)

    Thiago Coutinho

    2012-06-01

    fueron operados en un solo nivel, 67 pacientes en dos, 17 en tres niveles, siendo 4 niveles en seis. Los resultados clínicos y radiológicos fueron recolectados antes de la operación, 1 semana, y 1, 3 y 6 meses y anualmente. Cuestionarios de NDI/VAS se utilizaron para evaluar el dolor y los resultados funcionales. Para el análisis de la degeneración de las facetas, se utilizó una escala de cuatro grados basada ​​en la tomografía computarizada. RESULTADOS: Los resultados clínicos han mejorado significativamente en todas las visitas posoperatorias. La mayoría de los pacientes progresó hasta los grados I y II de degeneración facetária, y en estos casos no hubo deterioro clínico, a diferencia de los casos con grados III y IV. Entre los niveles estudiados, 25 (8,93% mostraron algún grado de HO: 14 fueron de grado I (56%, 7 de grado II (28%, tres con grado III (12% y solo uno de grado IV (4%. En 92% de los pacientes, que desarrollaron HO, había incipiente presencia de osteofitos. La enfermedad de niveles adyacentes se produjo en el 5,7% de los pacientes. CONCLUSIÓN: Los buenos resultados clínicos también corroboran la superioridad de CTDR en comparación con los resultados del ACDF descritos en la literatura.OBJECTIVE: To present the clinical and radiological experience of cervical arthroplasty in the treatment of intervertebral disc degeneration, maintaining movement and reducing adjacent segments stress and degeneration. METHODS: We studied the radiographs of 280 levels in 161 patients (mean age 45.4 years treated between cervical levels C3-4 and C7-T1. Seventy-one patients were operated at one disc level, 67 at two, 17 at three, and 6 at four levels. Radiological and clinical outcomes were collected preoperatively, 1 week and 1, 3 and 6 months and annually. NDI/VAS questionnaires were used to assess pain and functional outcomes. For facet degeneration analysis, we used a four-grade scale based on CT scans. RESULTS: The clinical outcomes significantly

  7. Flued head replacement alternatives

    International Nuclear Information System (INIS)

    Smetters, J.L.

    1987-01-01

    This paper discusses flued head replacement options. Section 2 discusses complete flued head replacement with a design that eliminates the inaccessible welds. Section 3 discusses alternate flued head support designs that can drastically reduce flued head installation costs. Section 4 describes partial flued head replacement designs. Finally, Section 5 discusses flued head analysis methods. (orig./GL)

  8. Capital Equipment Replacement Decisions

    OpenAIRE

    Batterham, Robert L.; Fraser, K.I.

    1995-01-01

    This paper reviews the literature on the optimal replacement of capital equipment, especially farm machinery. It also considers the influence of taxation and capital rationing on replacement decisions. It concludes that special taxation provisions such as accelerated depreciation and investment allowances are unlikely to greatly influence farmers' capital equipment replacement decisions in Australia.

  9. Implementing Replacement Cost Accounting

    Science.gov (United States)

    1976-12-01

    cost accounting Clickener, John Ross Monterey, California. Naval Postgraduate School http://hdl.handle.net/10945/17810 Downloaded from NPS Archive...Calhoun IMPLEMENTING REPLACEMENT COST ACCOUNTING John Ross CHckener NAVAL POSTGRADUATE SCHOOL Monterey, California THESIS IMPLEMENTING REPLACEMENT COST ...Implementing Replacement Cost Accounting 7. AUTHORS John Ross Clickener READ INSTRUCTIONS BEFORE COMPLETING FORM 3. RECIPIENT’S CATALOG NUMBER 9. TYRE OF

  10. A dynamic model-based approach to motion and deformation tracking of prosthetic valves from biplane x-ray images.

    Science.gov (United States)

    Wagner, Martin G; Hatt, Charles R; Dunkerley, David A P; Bodart, Lindsay E; Raval, Amish N; Speidel, Michael A

    2018-04-16

    Transcatheter aortic valve replacement (TAVR) is a minimally invasive procedure in which a prosthetic heart valve is placed and expanded within a defective aortic valve. The device placement is commonly performed using two-dimensional (2D) fluoroscopic imaging. Within this work, we propose a novel technique to track the motion and deformation of the prosthetic valve in three dimensions based on biplane fluoroscopic image sequences. The tracking approach uses a parameterized point cloud model of the valve stent which can undergo rigid three-dimensional (3D) transformation and different modes of expansion. Rigid elements of the model are individually rotated and translated in three dimensions to approximate the motions of the stent. Tracking is performed using an iterative 2D-3D registration procedure which estimates the model parameters by minimizing the mean-squared image values at the positions of the forward-projected model points. Additionally, an initialization technique is proposed, which locates clusters of salient features to determine the initial position and orientation of the model. The proposed algorithms were evaluated based on simulations using a digital 4D CT phantom as well as experimentally acquired images of a prosthetic valve inside a chest phantom with anatomical background features. The target registration error was 0.12 ± 0.04 mm in the simulations and 0.64 ± 0.09 mm in the experimental data. The proposed algorithm could be used to generate 3D visualization of the prosthetic valve from two projections. In combination with soft-tissue sensitive-imaging techniques like transesophageal echocardiography, this technique could enable 3D image guidance during TAVR procedures. © 2018 American Association of Physicists in Medicine.

  11. Intracardiac echocardiography to diagnose pannus formation after aortic valve replacement.

    Science.gov (United States)

    Yamamoto, Yoshiya; Ohara, Takahiro; Funada, Akira; Takahama, Hiroyuki; Amaki, Makoto; Hasegawa, Takuya; Sugano, Yasuo; Kanzaki, Hideaki; Anzai, Toshihisa

    2016-03-01

    A 66-year-old female, under regular follow-up for 20 years after aortic valve replacement (19-mm Carbomedics), presented dyspnea on effort and hypotension during hemodialysis. A transthoracic echocardiogram showed elevation of transvalvular velocity up to 4 m/s, but the structure around the aortic prosthesis was difficult to observe due to artifacts. Fluoroscopy revealed normal motion of the leaflets of the mechanical valve. Intracardiac echocardiography (ICE) revealed a pannus-like structure in the left ventricular outflow tract. Transesophageal echocardiogram also revealed this structure. ICE can visualize structural abnormalities around a prosthetic valve after cardiac surgery even in patients in whom conventional imaging modalities failed.

  12. Image segmentation for enhancing symbol recognition in prosthetic vision.

    Science.gov (United States)

    Horne, Lachlan; Barnes, Nick; McCarthy, Chris; He, Xuming

    2012-01-01

    Current and near-term implantable prosthetic vision systems offer the potential to restore some visual function, but suffer from poor resolution and dynamic range of induced phosphenes. This can make it difficult for users of prosthetic vision systems to identify symbolic information (such as signs) except in controlled conditions. Using image segmentation techniques from computer vision, we show it is possible to improve the clarity of such symbolic information for users of prosthetic vision implants in uncontrolled conditions. We use image segmentation to automatically divide a natural image into regions, and using a fixation point controlled by the user, select a region to phosphenize. This technique improves the apparent contrast and clarity of symbolic information over traditional phosphenization approaches.

  13. Obtention of a prosthetic group for labelling of radioiodinated proteins

    International Nuclear Information System (INIS)

    Santos, Josefina da S.; Colturato, Maria Tereza; Araujo, Elaine B. de

    2000-01-01

    Antibodies and peptides labeled with radionuclides has been extensively used in radioimmunotherapy and radioimmunodetection. The principal problem with the use of radioiodinated proteins is the in vivo dehalogenation. The use of prosthetic groups for indirect labeling of proteins with radioiodine has showed to be useful on labeling proteins with greater in vivo stability. A procedure is described for the preparation of an radioiodinated prosthetic group (N-succinimidyl 4-radioiodine-benzoate-SIB), using procedure described by Stocklin et al, with the iodination of p-bromo-benzoic acid and subsequent reaction with TSTU. Preliminary labeling results showed that the prosthetic group can be obtained in a good yield. The coupling of the SIB to the protein will be studied using human IgG as protein model. (author)

  14. Surgical-prosthetic treatment of large mandibular cysts

    Directory of Open Access Journals (Sweden)

    Džambas Ljubiša D.

    2003-01-01

    Full Text Available This paper presents a combined surgical-prosthetic procedure of reconstructing mandibular bone defect in a 53 year old patient, following enucleation of a mandibular cyst (Cystectomy Partsch II. After a thorough diagnostic evaluation, a surgical procedure was planned with the particular attention to the nature of the disease, patient’s condition, size and extension of the cyst, tissue loss, and the possibilities of prosthetic management of a mandibular bone defect with partial postresection dental prosthesis. It is of great importance to point to the significance of teamwork of a maxillofacial surgeon and a specialist in prosthodontics. This kind of cooperation provided very effective and less risky soft tissue, as well as bone tissue regeneration (osteogenesis. The patient’s recovery was fast, and he could return to his daily activities and work without significant changes regarding quality of life after surgery and prosthetic treatment.

  15. Granulicatella adiacens prosthetic hip joint infection after dental treatment.

    Science.gov (United States)

    Aweid, Osama; Sundararajan, Sabapathy; Teferi, Abraham

    2016-06-01

    Granulicatella adiacens is a Gram-positive bacteria and a normal component of oral flora. It is also found in dental plaques, endodontic abscesses and can rarely cause more serious infections. We describe a prosthetic hip joint infection in an 81-year-old fit and healthy man due to Granulicatella adiacens who underwent a prolonged dental intervention two days earlier without antibiotic prophylaxis. The infection was successfully treated with surgical intervention and a combination of antibiotics. The patient eventually succumbed to severe community-acquired pneumonia two months later. Current guidelines recommend avoidance of antibiotic prophylaxis prior to dental treatment in patients who have no co-morbidities and no prior operation on the index prosthetic joint. This case report indicates that infections of prosthetic joints may be associated with dental procedures even in fit and healthy patients without the recognized risk factors.

  16. Future Research Opportunities in Peri-Prosthetic Joint Infection Prevention.

    Science.gov (United States)

    Berbari, Elie; Segreti, John; Parvizi, Javad; Berríos-Torres, Sandra I

    Peri-prosthetic joint infection (PJI) is a serious complication of prosthetic joint arthroplasty. A better understanding and reversal of modifiable risk factors may lead to a reduction in the incidence of incisional (superficial and deep) and organ/space (e.g., PJI) surgical site infections (SSI). Recently, the Centers for Disease Control and Prevention (CDC) and the Healthcare Infection Control Practices Advisory Committee (HICPAC) published the Guideline for Prevention of Surgical Site Infection. This targeted update applies evidence-based methodology in drafting recommendations for potential strategies to reduce the risk of SSI both across surgical procedures and specifically in prosthetic joint arthroplasty. A panel of PJI content experts identified nine PJI prevention research opportunities based on both evidence gaps identified through the guideline development process (transfusion, immunosuppressive therapy, anticoagulation, orthopedic space suit, and biofilm) and expert opinion (anesthesia, operative room environment, glycemic control, and Staphylococcus aureus nasal screening and decolonization. This article offers a road map for PJI prevention research.

  17. Uncemented allograft-prosthetic composite reconstruction of the proximal femur

    Directory of Open Access Journals (Sweden)

    Li Min

    2014-01-01

    Full Text Available Background: Allograft-prosthetic composite can be divided into three groups names cemented, uncemented, and partially cemented. Previous studies have mainly reported outcomes in cemented and partially cemented allograft-prosthetic composites, but have rarely focused on the uncemented allograft-prosthetic composites. The objectives of our study were to describe a surgical technique for using proximal femoral uncemented allograft-prosthetic composite and to present the radiographic and clinical results. Materials and Methods: Twelve patients who underwent uncemented allograft-prosthetic composite reconstruction of the proximal femur after bone tumor resection were retrospectively evaluated at an average followup of 24.0 months. Clinical records and radiographs were evaluated. Results: In our series, union occurred in all the patients (100%; range 5-9 months. Until the most recent followup, there were no cases with infection, nonunion of the greater trochanter, junctional bone resorption, dislocation, allergic reaction, wear of acetabulum socket, recurrence, and metastasis. But there were three periprosthetic fractures which were fixed using cerclage wire during surgery. Five cases had bone resorption in and around the greater trochanter. The average Musculoskeletal Tumor Society (MSTS score and Harris hip score (HHS were 26.2 points (range 24-29 points and 80.6 points (range 66.2-92.7 points, respectively. Conclusions: These results showed that uncemented allograft-prosthetic composite could promote bone union through compression at the host-allograft junction and is a good choice for proximal femoral resection. Although this technology has its own merits, long term outcomes are yet not validated.

  18. Sagittal alignment after single cervical disc arthroplasty.

    Science.gov (United States)

    Guérin, Patrick; Obeid, Ibrahim; Gille, Olivier; Bourghli, Anouar; Luc, Stéphane; Pointillart, Vincent; Vital, Jean-Marc

    2012-02-01

    Prospective study. To analyze the sagittal balance after single-level cervical disc replacement (CDR) and range of motion (ROM). To define clinical and radiologic parameters those have a significant correlation with segmental and overall cervical curvature after CDR. Clinical outcomes and ROM after CDR with Mobi-C (LDR, Troyes, France) prosthesis have been documented in few studies. No earlier report of this prosthesis has studied correlations between static and dynamic parameters or those between static parameters and clinical outcomes. Forty patients were evaluated. Clinical outcome was assessed using the Short Form-36 questionnaire, Neck Disability Index, and a Visual Analog Scale. Spineview software (Surgiview, Paris, France) was used to investigate sagittal balance parameters and ROM. The mean follow-up was 24.3 months (range: 12 to 36 mo). Clinical outcomes were satisfactory. There was a significant improvement of Short Form-36, Neck Disability Index, and Visual Analog Scale scores. Mean ROM was 8.3 degrees preoperatively and 11.0 degrees postoperatively (P=0.013). Mean preoperative C2C7 curvature was 12.8 and 16.0 degrees at last follow-up (P=0.001). Mean preoperative functional spinal unit (FSU) angle was 2.3 and 5.3 degrees postoperatively (P<0.0001). Mean postoperative shell angle was 5.5 degrees. There was a significant correlation between postoperative C2C7 alignment and preoperative C2C7 alignment, change of C2C7 alignment, preoperative and postoperative FSU angle, and prosthesis shell angle. There was also a significant correlation between postoperative FSU angle and preoperative C2C7 alignment, preoperative FSU angle, change of FSU angle, and prosthesis shell angle. Regression analysis showed that prosthesis shell angle and preoperative FSU angle contributed significantly to postoperative FSU angle. Moreover, preoperative C2C7 alignment, preoperative FSU angle, postoperative FSU angle, and prosthesis shell angle contributed significantly to

  19. Magnetic Oculomotor Prosthetics for Acquired Nystagmus.

    Science.gov (United States)

    Nachev, Parashkev; Rose, Geoff E; Verity, David H; Manohar, Sanjay G; MacKenzie, Kelly; Adams, Gill; Theodorou, Maria; Pankhurst, Quentin A; Kennard, Christopher

    2017-10-01

    Acquired nystagmus, a highly symptomatic consequence of damage to the substrates of oculomotor control, often is resistant to pharmacotherapy. Although heterogeneous in its neural cause, its expression is unified at the effector-the eye muscles themselves-where physical damping of the oscillation offers an alternative approach. Because direct surgical fixation would immobilize the globe, action at a distance is required to damp the oscillation at the point of fixation, allowing unhindered gaze shifts at other times. Implementing this idea magnetically, herein we describe the successful implantation of a novel magnetic oculomotor prosthesis in a patient. Case report of a pilot, experimental intervention. A 49-year-old man with longstanding, medication-resistant, upbeat nystagmus resulting from a paraneoplastic syndrome caused by stage 2A, grade I, nodular sclerosing Hodgkin's lymphoma. We designed a 2-part, titanium-encased, rare-earth magnet oculomotor prosthesis, powered to damp nystagmus without interfering with the larger forces involved in saccades. Its damping effects were confirmed when applied externally. We proceeded to implant the device in the patient, comparing visual functions and high-resolution oculography before and after implantation and monitoring the patient for more than 4 years after surgery. We recorded Snellen visual acuity before and after intervention, as well as the amplitude, drift velocity, frequency, and intensity of the nystagmus in each eye. The patient reported a clinically significant improvement of 1 line of Snellen acuity (from 6/9 bilaterally to 6/6 on the left and 6/5-2 on the right), reflecting an objectively measured reduction in the amplitude, drift velocity, frequency, and intensity of the nystagmus. These improvements were maintained throughout a follow-up of 4 years and enabled him to return to paid employment. This work opens a new field of implantable therapeutic devices-oculomotor prosthetics-designed to modify eye

  20. Prosthetic Mesh Repair for Incarcerated Inguinal Hernia

    Directory of Open Access Journals (Sweden)

    Cihad Tatar

    2016-08-01

    Full Text Available Background: Incarcerated inguinal hernia is a commonly encountered urgent surgical condition, and tension-free repair is a well-established method for the treatment of noncomplicated cases. However, due to the risk of prosthetic material-related infections, the use of mesh in the repair of strangulated or incarcerated hernia has often been subject to debate. Recent studies have demonstrated that biomaterials represent suitable materials for performing urgent hernia repair. Certain studies recommend mesh repair only for cases where no bowel resection is required; other studies, however, recommend mesh repair for patients requiring bowel resection as well. Aim: The aim of this study was to compare the outcomes of different surgical techniques performed for strangulated hernia, and to evaluate the effect of mesh use on postoperative complications. Study Design: Retrospective cross-sectional study. Methods: This retrospective study was performed with 151 patients who had been admitted to our hospital’s emergency department to undergo surgery for a diagnosis of incarcerated inguinal hernia. The patients were divided into two groups based on the applied surgical technique. Group 1 consisted of 112 patients treated with mesh-based repair techniques, while Group 2 consisted of 39 patients treated with tissue repair techniques. Patients in Group 1 were further divided into two sub-groups: one consisting of patients undergoing bowel resection (Group 3, and the other consisting of patients not undergoing bowel resection (Group 4. Results: In Group 1, it was observed that eight (7.14% of the patients had wound infections, while two (1.78% had hematomas, four (3.57% had seromas, and one (0.89% had relapse. In Group 2, one (2.56% of the patients had a wound infection, while three (7.69% had hematomas, one (2.56% had seroma, and none had relapses. There were no statistically significant differences between the two groups with respect to wound infection

  1. Diagnostic flowcharts in osteomyelitis, spondylodiscitis and prosthetic joint infection

    International Nuclear Information System (INIS)

    Jutte, P.; Lazzeri, E.; Sconfienza, L. M.; Cassar-Pullicino, V.; Trampuz, A.; Petrosillo, N.; Signore, A.

    2014-01-01

    Infections of the bone, spine and prosthetic joints are serious and complex conditions to diagnose and to treat. Structured diagnostic workup may very well improve the accuracy and speed of diagnosis, thereby improving the outcome since treatment may very well be more successful and less harmful if timely management is started. Literature shows no uniform advise on diagnosis. The EANM organized a consensus meeting with representatives from the involved disciplines in order to develop common flowcharts for the diagnosis of osteomyelitis, spondylodiscitis and prosthetic joint infections. In this report the proceedings of this consensus meeting, including the proposed flowcharts for diagnosis, are published.

  2. Cervical disc hernia operations through posterior laminoforaminotomy.

    Science.gov (United States)

    Yolas, Coskun; Ozdemir, Nuriye Guzin; Okay, Hilmi Onder; Kanat, Ayhan; Senol, Mehmet; Atci, Ibrahim Burak; Yilmaz, Hakan; Coban, Mustafa Kemal; Yuksel, Mehmet Onur; Kahraman, Umit

    2016-01-01

    The most common used technique for posterolateral cervical disc herniations is anterior approach. However, posterior cervical laminotoforaminomy can provide excellent results in appropriately selected patients with foraminal stenosis in either soft disc prolapse or cervical spondylosis. The purpose of this study was to present the clinical outcomes following posterior laminoforaminotomy in patients with radiculopathy. We retrospectively evaluated 35 patients diagnosed with posterolateral cervical disc herniation and cervical spondylosis with foraminal stenosis causing radiculopathy operated by the posterior cervical keyhole laminoforaminotomy between the years 2010 and 2015. The file records and the radiographic images of the 35 patients were assessed retrospectively. The mean age was 46.4 years (range: 34-66 years). Of the patients, 19 were males and 16 were females. In all of the patients, the neurologic deficit observed was radiculopathy. The posterolaterally localized disc herniations and the osteophytic structures were on the left side in 18 cases and on the right in 17 cases. In 10 of the patients, the disc level was at C5-6, in 18 at C6-7, in 2 at C3-4, in 2 at C4-5, in 1 at C7-T1, in 1 patient at both C5-6 and C6-7, and in 1 at both C4-5 and C5-6. In 14 of these 35 patients, both osteophytic structures and protruded disc herniation were present. Intervertebral foramen stenosis was present in all of the patients with osteophytes. Postoperatively, in 31 patients the complaints were relieved completely and four patients had complaints of neck pain and paresthesia radiating to the arm (the success of operation was 88.5%). On control examinations, there was no finding of instability or cervical kyphosis. Posterior cervical laminoforaminotomy is an alternative appropriate choice in both cervical soft disc herniations and cervical stenosis.

  3. Cervical disc hernia operations through posterior laminoforaminotomy

    Directory of Open Access Journals (Sweden)

    Coskun Yolas

    2016-01-01

    Full Text Available Objective: The most common used technique for posterolateral cervical disc herniations is anterior approach. However, posterior cervical laminotoforaminomy can provide excellent results in appropriately selected patients with foraminal stenosis in either soft disc prolapse or cervical spondylosis. The purpose of this study was to present the clinical outcomes following posterior laminoforaminotomy in patients with radiculopathy. Materials and Methods: We retrospectively evaluated 35 patients diagnosed with posterolateral cervical disc herniation and cervical spondylosis with foraminal stenosis causing radiculopathy operated by the posterior cervical keyhole laminoforaminotomy between the years 2010 and 2015. Results: The file records and the radiographic images of the 35 patients were assessed retrospectively. The mean age was 46.4 years (range: 34-66 years. Of the patients, 19 were males and 16 were females. In all of the patients, the neurologic deficit observed was radiculopathy. The posterolaterally localized disc herniations and the osteophytic structures were on the left side in 18 cases and on the right in 17 cases. In 10 of the patients, the disc level was at C5-6, in 18 at C6-7, in 2 at C3-4, in 2 at C4-5, in 1 at C7-T1, in 1 patient at both C5-6 and C6-7, and in 1 at both C4-5 and C5-6. In 14 of these 35 patients, both osteophytic structures and protruded disc herniation were present. Intervertebral foramen stenosis was present in all of the patients with osteophytes. Postoperatively, in 31 patients the complaints were relieved completely and four patients had complaints of neck pain and paresthesia radiating to the arm (the success of operation was 88.5%. On control examinations, there was no finding of instability or cervical kyphosis. Conclusion: Posterior cervical laminoforaminotomy is an alternative appropriate choice in both cervical soft disc herniations and cervical stenosis.

  4. Only marginal alignment of disc galaxies

    Science.gov (United States)

    Andrae, René; Jahnke, Knud

    2011-12-01

    Testing theories of angular-momentum acquisition of rotationally supported disc galaxies is the key to understanding the formation of this type of galaxies. The tidal-torque theory aims to explain this acquisition process in a cosmological framework and predicts positive autocorrelations of angular-momentum orientation and spiral-arm handedness, i.e. alignment of disc galaxies, on short distance scales of 1 Mpc h-1. This disc alignment can also cause systematic effects in weak-lensing measurements. Previous observations claimed discovering these correlations but are overly optimistic in the reported level of statistical significance of the detections. Errors in redshift, ellipticity and morphological classifications were not taken into account, although they have a significant impact. We explain how to rigorously propagate all the important errors through the estimation process. Analysing disc galaxies in the Sloan Digital Sky Survey (SDSS) data base, we find that positive autocorrelations of spiral-arm handedness and angular-momentum orientations on distance scales of 1 Mpc h-1 are plausible but not statistically significant. Current data appear not good enough to constrain parameters of theory. This result agrees with a simple hypothesis test in the Local Group, where we also find no evidence for disc alignment. Moreover, we demonstrate that ellipticity estimates based on second moments are strongly biased by galactic bulges even for Scd galaxies, thereby corrupting correlation estimates and overestimating the impact of disc alignment on weak-lensing studies. Finally, we discuss the potential of future sky surveys. We argue that photometric redshifts have too large errors, i.e. PanSTARRS and LSST cannot be used. Conversely, the EUCLID project will not cover the relevant redshift regime. We also discuss the potentials and problems of front-edge classifications of galaxy discs in order to improve the autocorrelation estimates of angular-momentum orientation.

  5. Star-disc interaction in galactic nuclei: formation of a central stellar disc

    Science.gov (United States)

    Panamarev, Taras; Shukirgaliyev, Bekdaulet; Meiron, Yohai; Berczik, Peter; Just, Andreas; Spurzem, Rainer; Omarov, Chingis; Vilkoviskij, Emmanuil

    2018-05-01

    We perform high-resolution direct N-body simulations to study the effect of an accretion disc on stellar dynamics in an active galactic nucleus (AGN). We show that the interaction of the nuclear stellar cluster (NSC) with the gaseous accretion disc (AD) leads to formation of a stellar disc in the central part of the NSC. The accretion of stars from the stellar disc on to the super-massive black hole is balanced by the capture of stars from the NSC into the stellar disc, yielding a stationary density profile. We derive the migration time through the AD to be 3 per cent of the half-mass relaxation time of the NSC. The mass and size of the stellar disc are 0.7 per cent of the mass and 5 per cent of the influence radius of the super-massive black hole. An AD lifetime shorter than the migration time would result in a less massive nuclear stellar disc. The detection of such a stellar disc could point to past activity of the hosting galactic nucleus.

  6. Adapting to change: influence of a microprocessor-controlled prosthetic knee on gait adaptations

    NARCIS (Netherlands)

    Prinsen, Erik Christiaan

    2016-01-01

    Advancement in prosthetic knee design have led to the introduction of microprocessor-controlled prosthetic knees (MPKs). MPKs incorporate sensors that are able to measure prosthetic loading, the knee angle, and knee angular velocity. Based on the sensor information, MPKs determine the optimal level

  7. Radiological assessment of loss of disc height during acute and chronic degenerative lumbar disc alterations

    International Nuclear Information System (INIS)

    Zoellner, J.; Sancaktaroglu, T.; Nafe, B.; Eysel, P.; Loew, R.

    2001-01-01

    Aim of the study: A loss of disc height with increasing segmental mobility is an important reason for low back pain. The measurement of hyaluronic acid content of the nucleus pulposus prolaps shows a difference between acute (group 1) and chronic (group 2) disc degeneration. The purpose of the present investigation was to determine the decreasing of disc height between these two groups and the no-symptomatic segments of these patients. Methods: 20 human lateral preoperative X-ray measurements according to Frobin et al. were taken; group 1 with 7 patients (mean age 41 years) and group 2 with 13 patients (mean age 44 years). Results: There was a significant tendency (p=0.091) to a reduction of disc height in group 2 between symptomatic and asymptomatic discs. Conclusion: The used method is not suitable to answer the present question conclusively. (orig.) [de

  8. Evaluation Of Factors Influencing On Causes Of Prosthetic Valve Re-operation And Early Postoperative Survival Tehran Emam hospital (1991-2001

    Directory of Open Access Journals (Sweden)

    Rahmani Reaza

    2003-06-01

    Full Text Available Prosthetic valve re-operation has greater mortality and morbidity than primary valve replacement. By recognition of factors influencing on causes of redo operation and preoperative survival, one can select appropriate prosthesis at primary valve replacement and when operation performed at appropriate time, surgical risk can be reduced."nMethods and Materials: Two hundred patients that underwent prosthetic valve re-operation from October 1991 through November 2001 were included in this study. There were 68 men and 132 women with the mean age of 42:tl 1.8 years. Structural failure was the commonest cause of bio-prosthesis replacement (93%. Valve thrombosis was the common cause of mechanical valve replacement (32%. Age younger Than 50 (P= 0.01 and interval after the first implantation more than 10 years (P= 0.01 affected bio-prosthesis degeneration."nResults: Atrial fibrillation (P<0.01, Older age especially more than 40 (P<0.05 and mitral position (P<0.01 affected mechanical valve thrombosis. Cross clamp time (P= 0.005, Tricuspid insufficiency (P = 0.001, NYHA IV (P = 0.005 and emergent operation (P= 0.001 were independent determinants of hospital mortality."nConclusion: In conclusion, in patients with more than 10-years life expectancy and age younger than 50, mechanical valve can be selected for primary valve replacement. If operation performed before patients reach deteriorated condition, preoperative survival would be excellent.

  9. Pre-prosthetic surgical alterations in maxillectomy to enhance the prosthetic prognoses as part of rehabilitation of oral cancer patient.

    Science.gov (United States)

    El Fattah, H; Zaghloul, A; Pedemonte, E; Escuin, T

    2012-03-01

    After maxillectomy, prosthetic restoration of the resulting defect is an essential step because it signals the beginning of patient's rehabilitation. The obturator used to restore the defect should be comfortable, restore adequate speech, deglutition, mastication, and be cosmetically acceptable, success will depend on the size and location of the defect and the quantity and integrity of the remaining structures, in addition to pre-prosthetic surgical preparation of defect site. Preoperative cooperation between the oncologist surgeon and the maxillofacial surgeon may allow obturation of a resultant defect by preservation of the premaxilla or the tuberosity on the defect side and maintaining the alveolar bone or teeth adjacent to the defect. This study evaluates the importance of pre-prosthetic surgical alterations at the time maxillectomy on the enhancement of the prosthetic prognoses as part of the rehabilitation of oral cancer patient. The study was carried out between 2003- 2008, on 66 cancer patients(41 male-25 female) age ranged from 33 to 72 years, at National Cancer Institute, Cairo University, whom underwent maxillectomy surgery to remove malignant tumor as a part of cancer treatment. Patients were divided in two groups. Group A: Resection of maxilla followed by preprosthetic surgical preparation. Twenty-four cancer patients (13 male - 11 female). Group B: Resection of maxilla without any preprosthetic surgical preparation. Forty-two cancer patients (28 male-14 female). Outcome variables measured included facial contour and aesthetic results, speech understandability, ability to eat solid foods, oronasal separation, socializing outside the home, and return-to-work status. Flap success and donor site morbidity were also studied. To improve the prosthetic restoration of maxillary defect resulting maxillary resection as part treatment of maxillofacial tumor depends on the close cooperation between prosthodontist and surgeon, by combination of pre-prosthetic

  10. DZ Chamaeleontis: a bona fide photoevaporating disc

    Science.gov (United States)

    Canovas, H.; Montesinos, B.; Schreiber, M. R.; Cieza, L. A.; Eiroa, C.; Meeus, G.; de Boer, J.; Ménard, F.; Wahhaj, Z.; Riviere-Marichalar, P.; Olofsson, J.; Garufi, A.; Rebollido, I.; van Holstein, R. G.; Caceres, C.; Hardy, A.; Villaver, E.

    2018-02-01

    Context. DZ Cha is a weak-lined T Tauri star (WTTS) surrounded by a bright protoplanetary disc with evidence of inner disc clearing. Its narrow Hα line and infrared spectral energy distribution suggest that DZ Cha may be a photoevaporating disc. Aims: We aim to analyse the DZ Cha star + disc system to identify the mechanism driving the evolution of this object. Methods: We have analysed three epochs of high resolution optical spectroscopy, photometry from the UV up to the sub-mm regime, infrared spectroscopy, and J-band imaging polarimetry observations of DZ Cha. Results: Combining our analysis with previous studies we find no signatures of accretion in the Hα line profile in nine epochs covering a time baseline of 20 yr. The optical spectra are dominated by chromospheric emission lines, but they also show emission from the forbidden lines [SII] 4068 and [OI] 6300Å that indicate a disc outflow. The polarized images reveal a dust depleted cavity of 7 au in radius and two spiral-like features, and we derive a disc dust mass limit of Mdust 80 MJup) companions are detected down to 0.̋07 ( 8 au, projected). Conclusions: The negligible accretion rate, small cavity, and forbidden line emission strongly suggests that DZ Cha is currently at the initial stages of disc clearing by photoevaporation. At this point the inner disc has drained and the inner wall of the truncated outer disc is directly exposed to the stellar radiation. We argue that other mechanisms like planet formation or binarity cannot explain the observed properties of DZ Cha. The scarcity of objects like this one is in line with the dispersal timescale (≲105 yr) predicted by this theory. DZ Cha is therefore an ideal target to study the initial stages of photoevaporation. Based on observations collected at the European Organisation for Astronomical Research in the Southern Hemisphere under ESO programme 097.C-0536. Based on data obtained from the ESO Science Archive Facility under request number 250112.

  11. INJURIES IN DISC GOLF - A DESCRIPTIVE CROSS-SECTIONAL STUDY

    DEFF Research Database (Denmark)

    Rahbek, Martin Amadeus; Nielsen, Rasmus Oestergaard

    2016-01-01

    BACKGROUND: Disc golf is rapidly increasing in popularity and more than two million people are estimated to regularly participate in disc golf activities. Despite this popularity, the epidemiology of injuries in disc golf remains under reported. PURPOSE: The purpose of the present study...... was to investigate the prevalence and anatomic distribution of injuries acquired through disc-golf participation in Danish disc golf players. METHODS: The study was a cross-sectional study conducted on Danish disc-golf players. In May 2015, invitations to complete a web-based questionnaire were spread online via...... social media, and around disc-golf courses in Denmark. The questionnaire included questions regarding disc-golf participation and the characteristics of injuries acquired through disc golf participation. The data was analyzed descriptively. RESULTS: An injury prevalence of 13.3% (95% CI: 6.7% to 19...

  12. MRI findings of traumatic cervical disc herniation

    International Nuclear Information System (INIS)

    Tanaka, Hisato; Kasahara, Takaki; Akiyama, Nanae

    2011-01-01

    In general practice, disc hernia is increasingly being questioned about its relation with traffic injuries. In this study, we examined the image findings of cervical disc herniation for findings indicative of traumatic hernia. In 2008, we examined 35 cases of cervical disc herniation at our hospital by MRI. The patients were divided into two groups; patients with trauma history (19 cases) and those without (16 cases), and their images were compared. Disc herniation in the trauma group showed high intensity at T2, with some of the patients in this group also indicating continuous high intensity of the internal and herniated discs. Traumatic force was found to cause swelling under the laryngeal soft tissue. Cases with further flexion injury showed interspinous ligament hemorrhage. These findings strongly suggest the involvement of injury. But given that some younger patients in the non-trauma group also show high intensity at T2*, attention must be paid not to confuse swelling below the larynx with inflammation of the longus colli muscle. (author)

  13. Active galactic nucleus outflows in galaxy discs

    Science.gov (United States)

    Hartwig, Tilman; Volonteri, Marta; Dashyan, Gohar

    2018-05-01

    Galactic outflows, driven by active galactic nuclei (AGNs), play a crucial role in galaxy formation and in the self-regulated growth of supermassive black holes (BHs). AGN feedback couples to and affects gas, rather than stars, and in many, if not most, gas-rich galaxies cold gas is rotationally supported and settles in a disc. We present a 2D analytical model for AGN-driven outflows in a gaseous disc and demonstrate the main improvements, compared to existing 1D solutions. We find significant differences for the outflow dynamics and wind efficiency. The outflow is energy-driven due to inefficient cooling up to a certain AGN luminosity (˜1043 erg s-1 in our fiducial model), above which the outflow remains momentum-driven in the disc up to galactic scales. We reproduce results of 3D simulations that gas is preferentially ejected perpendicular to the disc and find that the fraction of ejected interstellar medium is lower than in 1D models. The recovery time of gas in the disc, defined as the free-fall time from the radius to which the AGN pushes the ISM at most, is remarkably short, of the order 1 Myr. This indicates that AGN-driven winds cannot suppress BH growth for long. Without the inclusion of supernova feedback, we find a scaling of the BH mass with the halo velocity dispersion of MBH ∝ σ4.8.

  14. Aeronautical Information System Replacement -

    Data.gov (United States)

    Department of Transportation — Aeronautical Information System Replacement is a web-enabled, automation means for the collection and distribution of Service B messages, weather information, flight...

  15. Development of injectable hydrogels for nucleus pulposus replacement

    Science.gov (United States)

    Thomas, Jonathan D.

    Intervertebral disc degeneration has been reported as the underlying cause for 75% of cases of lower back pain and is marked by dehydration of the nucleus pulposus within the intervertebral disc. There have been many implant designs to replace the nucleus pulposus. Some researchers have proposed the replacement of the nucleus pulposus with hydrogel materials. The insertion of devices made from these materials further compromises the annulus of the disc. An ideal nucleus replacement could be injected into the disc space and form a solid in vivo. However, injectable replacements using curing elastomers and thermoplastic materials are not ideal because of the potentially harmful exothermic heat evolved from their reactions and the toxicity of the reactants used. We propose a hydrogel system that can be injected as a liquid at 25°C and solidified to yield a hydrogel within the intervertebral disc at 37°C. In aqueous solutions, these polymers have Lower Critical Solution Temperatures (LCST) between 25-37°C, making them unique candidate materials for this application. Poly(N-isopropylacrylamide) (PNIPAAm) is the most widely studied LCST polymer due to its drastic transition near body temperature. However, by itself, pure PNIPAAm forms a hydrogel that has low water content and can readily undergo plastic deformation. To increase the water content and impart elasticity to PNIPAAm hydrogels, grafted and branched hydrogel systems were created that incorporated the thermogelling PNIPAAm and hydrophilic poly(ethylene glycol) (PEG). In this research, the effects of polymer composition and monomer to initiator ratio, which controls polymer MW, on the in vitro swelling properties (mass, chemical, and compressive mechanical stability) of hydrogels formed from aqueous solutions of these polymers were evaluated. Immersion studies were also conducted in solutions to simulate the osmotic environment of the nucleus pulposus. The effects of repeated compression and unloading cycles

  16. Early prosthetic valve endocarditis caused by Corynebacterium kroppenstedtii.

    Science.gov (United States)

    Hagemann, Jürgen Benjamin; Essig, Andreas; Herrmann, Manuel; Liebold, Andreas; Quader, Mohamed Abo

    2015-12-01

    Corynebacterium (C.) kroppenstedtii is a rarely detected agent of bacterial infections in humans. Here, we describe the first case of prosthetic valve endocarditis caused by C. kroppenstedtii. Application of molecular methods using surgically excised valve tissue was a cornerstone for the establishment of the microbiological diagnosis, which is crucial for targeted antimicrobial treatment. Copyright © 2015 Elsevier GmbH. All rights reserved.

  17. Development of a 3D-Printed Robotic Prosthetic Arm

    Energy Technology Data Exchange (ETDEWEB)

    Gomez Martinez, M.; Garcia-Miquel, A.; Vidal Martinez, N.

    2016-07-01

    Current prostheses are not affordable to the general public. 3D printing technology may allow low-cost production of such devices, making them more readily accessible to people in need. This contribution presents the set-up and the considerations that have to be taken into account to develop a functional artificial upper limb prototype. The robotic prosthetic arm reported herein was produced entirely using 3D printing technology to demonstrate its feasibility on a limited budget. The project was developed to integrate two different functional modes: a prosthetic application and a remote application. The prosthetic application is intended to emulate existing prosthetic devices using myoelectric sensors. The remote application is conceived as a tool for prevention, by providing the general public with a device that could carry out activities that entail a risk of severe physical injury. This is achieved using a hand-tracking system that allows the robotic arm to copy the user’s movements remotely and in real time. The outcome of the validation tests has been considerably successful for both applications and the total costs are on target. (Author)

  18. Consumer satisfaction with the services of prosthetics and orthotics facilities

    NARCIS (Netherlands)

    Bosmans, Joline; Geertzen, Jan; Dijkstra, Pieter U.

    2009-01-01

    Consumer satisfaction with the services provided in a prosthetics and orthotics (PO) facility has seldom been studied. The aim of this study was to analyze consumer satisfaction regarding the services provided by 15 PO facilities in The Netherlands. Consumers (n=1,364) of these PO facilities who

  19. Esthetics with prosthetics in case of maxillary canine transposition: A ...

    African Journals Online (AJOL)

    Esthetics with prosthetics in case of maxillary canine transposition: A clinical report. ... provides a helpful Frequently Asked Questions about PDFs. Alternatively, you can download the PDF file directly to your computer, from where it can be opened using a PDF reader. To download the PDF, click the Download link above.

  20. Determining asymmetry of roll-over shapes in prosthetic walking

    NARCIS (Netherlands)

    Curtze, C.; Otten, Bert; Hof, A.L.; Postema, K.

    2011-01-01

    How does the inherent asymmetry of the locomotor system in people with lower-limb amputation affect the ankle-foot roll-over shape of prosthetic walking? In a single-case design, we evaluated the walking patterns of six people with lower-limb amputation (3 transtibial and 3 transfemoral) and three

  1. Diagnostic evaluation of left-sided prosthetic heart valve dysfunction

    NARCIS (Netherlands)

    Habets, Jesse; Budde, Ricardo P.; Symersky, Petr; van den Brink, Renee B.; de Mol, Bas A.; Mali, Willem P.; van Herwerden, Lex A.; Chamuleau, Steven A.

    Prosthetic heart valve (PHV) dysfunction is a rare, but potentially life-threatening, complication. In clinical practice, PHV dysfunction poses a diagnostic dilemma. Echocardiography and fluoroscopy are the imaging techniques of choice and are routinely used in daily practice. However, these

  2. Diagnostic evaluation of left-sided prosthetic heart valve dysfunction

    NARCIS (Netherlands)

    Habets, Jesse; Budde, Ricardo P.; Symersky, Petr; van den Brink, Renee B.; de Mol, Bas A.; Mali, Willem P.; van Herwerden, Lex A.; Chamuleau, Steven A.

    2011-01-01

    Prosthetic heart valve (PHV) dysfunction is a rare, but potentially life-threatening, complication. In clinical practice, PHV dysfunction poses a diagnostic dilemma. Echocardiography and fluoroscopy are the imaging techniques of choice and are routinely used in daily practice. However, these

  3. Development of a prototype over-actuated biomimetic prosthetic hand.

    Directory of Open Access Journals (Sweden)

    Matthew R Williams

    Full Text Available The loss of a hand can greatly affect quality of life. A prosthetic device that can mimic normal hand function is very important to physical and mental recuperation after hand amputation, but the currently available prosthetics do not fully meet the needs of the amputee community. Most prosthetic hands are not dexterous enough to grasp a variety of shaped objects, and those that are tend to be heavy, leading to discomfort while wearing the device. In order to attempt to better simulate human hand function, a dexterous hand was developed that uses an over-actuated mechanism to form grasp shape using intrinsic joint mounted motors in addition to a finger tendon to produce large flexion force for a tight grip. This novel actuation method allows the hand to use small actuators for grip shape formation, and the tendon to produce high grip strength. The hand was capable of producing fingertip flexion force suitable for most activities of daily living. In addition, it was able to produce a range of grasp shapes with natural, independent finger motion, and appearance similar to that of a human hand. The hand also had a mass distribution more similar to a natural forearm and hand compared to contemporary prosthetics due to the more proximal location of the heavier components of the system. This paper describes the design of the hand and controller, as well as the test results.

  4. Diagnostic flowcharts in osteomyelitis, spondylodiscitis and prosthetic joint infection

    NARCIS (Netherlands)

    Jutte, P.; Lazzeri, E.; Sconfienza, L. M.; Cassar-Pullicino, V.; Trampuz, A.; Petrosillo, N.; Signore, A.

    Infections of the bone, spine and prosthetic joints are serious and complex conditions to diagnose and to treat. Structured diagnostic workup may very well improve the accuracy and speed of diagnosis, thereby improving the outcome since treatment may very well be more successful and less harmful if

  5. Effect of Modifying Prosthetic Socket Base Materials by Adding Nanodiamonds

    Directory of Open Access Journals (Sweden)

    Lifang Ma

    2015-01-01

    Full Text Available The curing process of prosthetic socket base materials requires attention owing to a series of associated problems that are yet to be addressed and solved. However, to date, few relevant studies have been reported. In this paper, nanodiamonds modified with a silane coupling agent were dispersed into a prosthetic socket base material, and the performance of the modified base materials was investigated. Adding a predetermined amount of nanodiamonds to the prosthetic socket base material increased the glass transition temperature, improved the mechanical properties of the cured base material, and reduced the influence of the volatile gas formed during the curing process on the environment. With increasing nanodiamond contents, the glass transition temperature increased and the mechanical properties improved slightly. Owing to the high thermal conductivity of the nanodiamonds, the localized heat, as a result of the curing process, could be dissipated and released. Thus, adding nanodiamonds led to a more uniform temperature field forming in the curing system. This improved the curing process and reduced the formation of volatile monomers, thereby decreasing the adverse impact of the generated volatile gases on the environment. All of these provide a potential strategy for modifying prosthetic socket base materials.

  6. Prosthetic prescription in the Netherlands : an observational study

    NARCIS (Netherlands)

    van der Linde, H; Geertzen, JHB; Hofstad, CJ; Postema, K; Van Limbeek, Jacques

    2003-01-01

    Prosthetic prescription for lower limb amputees and the methodology used are primarily based on empirical knowledge. Clinical expertise plays an important role that can lead to an adequate prescription; however, a clear evidence based motivation for the choices made cannot be given. This can lead to

  7. Jamming Transition: Heptagons, Pentagons, and Discs

    Directory of Open Access Journals (Sweden)

    Xu Yuanyuan

    2017-01-01

    Full Text Available The jamming behavior of a system composed of discs has been well documented. However, it remains unclear how a granular system consisting of non-spherical particles transitions between unjammed and jammed states. Here, we present compression experiments to study the jamming transition of 2D granular materials composed of photoelastic heptagonal particles and compare these results to data for discs and pentagons. We determine the critical packing fraction of heptagons and make a comparison to discs and pentagons. In the experiment, we subject 618 heptagonal particles to cyclic compression. We track the motion (inlcuding rotations of the particles, and we measure forces on particles by photoelasticity. We observe a power law relationship between the average contact number (Z and the pressure (P. Furthermore, we classify the type of contacts by the relative orientation of pairs of contacting particles (creating point-to-face and face-to-face contacts, and we explore the evolution of the contacts during jamming.

  8. On the formation of exponential discs

    International Nuclear Information System (INIS)

    Yoshii, Yuzuru; Sommer-Larsen, Jesper

    1989-01-01

    Spiral galaxy discs are characterized by approximately exponential surface luminosity profiles. In this paper the evolutionary equations for a star-forming, viscous disc are solved analytically or semi-analytically. It is shown that approximately exponential stellar surface density profiles result if the viscous time-scale t ν is comparable to the star-formation time scale t * everywhere in the disc. The analytical solutions are used to illuminate further on the issue of why the above mechanism leads to resulting exponential stellar profiles under certain conditions. The sensitivity of the solution to variations of various parameters are investigated and show that the initial gas surface density distribution has to be fairly regular in order that final exponential stellar surface density profiles result. (author)

  9. Optic disc pit with sectorial retinitis pigmentosa.

    Science.gov (United States)

    Balikoglu-Yilmaz, Melike; Taskapili, Muhittin; Yilmaz, Tolga; Teke, Mehmet Yasin

    2013-01-01

    Sectorial retinitis pigmentosa (RP) and optic disc pit (ODP) are rare clinical conditions. We present a 40-year-old woman with a history of mild night blindness and decreased vision in the right eye for about 5 years. Fundus examination revealed retinal pigmentary changes in the superior and inferotemporal sectors covering the macula and reduced arterial calibre and ODP at the temporal edge of the optic disc. In addition, fundus autofluorescence, spectral-domain optical coherence tomography, fluorescein angiography, and multifocal electroretinogram scans confirmed these clinical findings. Visual acuity was decreased due to an atrophic-appearing foveal lesion. No intervention was suggested because of the poor visual potential. To the best of our knowledge, the present study is the first to describe coexistent optic disc pit and sectorial RP in the superior and inferotemporal sectors covering the macula in the same eye with figures.

  10. Optic Disc Pit with Sectorial Retinitis Pigmentosa

    Directory of Open Access Journals (Sweden)

    Melike Balikoglu-Yilmaz

    2013-01-01

    Full Text Available Sectorial retinitis pigmentosa (RP and optic disc pit (ODP are rare clinical conditions. We present a 40-year-old woman with a history of mild night blindness and decreased vision in the right eye for about 5 years. Fundus examination revealed retinal pigmentary changes in the superior and inferotemporal sectors covering the macula and reduced arterial calibre and ODP at the temporal edge of the optic disc. In addition, fundus autofluorescence, spectral-domain optical coherence tomography, fluorescein angiography, and multifocal electroretinogram scans confirmed these clinical findings. Visual acuity was decreased due to an atrophic-appearing foveal lesion. No intervention was suggested because of the poor visual potential. To the best of our knowledge, the present study is the first to describe coexistent optic disc pit and sectorial RP in the superior and inferotemporal sectors covering the macula in the same eye with figures.

  11. Imaging cell competition in Drosophila imaginal discs.

    Science.gov (United States)

    Ohsawa, Shizue; Sugimura, Kaoru; Takino, Kyoko; Igaki, Tatsushi

    2012-01-01

    Cell competition is a process in which cells with higher fitness ("winners") survive and proliferate at the expense of less fit neighbors ("losers"). It has been suggested that cell competition is involved in a variety of biological processes such as organ size control, tissue homeostasis, cancer progression, and the maintenance of stem cell population. By advent of a genetic mosaic technique, which enables to generate fluorescently marked somatic clones in Drosophila imaginal discs, recent studies have presented some aspects of molecular mechanisms underlying cell competition. Now, with a live-imaging technique using ex vivo-cultured imaginal discs, we can dissect the spatiotemporal nature of competitive cell behaviors within multicellular communities. Here, we describe procedures and tips for live imaging of cell competition in Drosophila imaginal discs. Copyright © 2012 Elsevier Inc. All rights reserved.

  12. Calcification of intervertebral discs in children

    International Nuclear Information System (INIS)

    Hoermann, D.

    1984-01-01

    Thirteen children with intervertebral disc calcifications of the cervical, thoracal and lumbar spine have been diagnosed since 1970. Most of them were observed over a period of several years. Ten children fell ill with acute pains, but only 2 of them sufferred from a trauma. In 3 cases the features were discovered accidentally combined with malformations of vertebral bodies and congenital diseases. Our results suggest a primary structural inferiority of the calcified discs. The calcifications arise partially from a birth trauma, partially from an unknown etiology. They can last for a long time without symptoms. An acute event effects the pains due to shifting or herniation of calcified disc-fragments. Secondary findings such as decrease of the height of cervical vertebral bodies or destructions of the endplates of thoracal and lumbar vertebral bodies disappear retarded and often incompletely and demand a control for a long time. (orig.)

  13. Appearance of Keplerian discs orbiting Kerr superspinars

    Energy Technology Data Exchange (ETDEWEB)

    Stuchlik, Zdenek; Schee, Jan, E-mail: zdenek.stuchlik@fpf.slu.c, E-mail: jan.schee@fpf.slu.c [Institute of Physics, Faculty of Philosophy and Science, Silesian University in Opava, Bezrucovo nam. 13, Opava (Czech Republic)

    2010-11-07

    We study optical phenomena related to the appearance of Keplerian accretion discs orbiting Kerr superspinars predicted by string theory. The superspinar exterior is described by standard Kerr naked singularity geometry breaking the black hole limit on the internal angular momentum (spin). We construct local photon escape cones for a variety of orbiting sources that enable us to determine the superspinars silhouette in the case of distant observers. We show that the superspinar silhouette depends strongly on the assumed edge where the external Kerr spacetime is joined to the internal spacetime governed by string theory and significantly differs from the black hole silhouette. The appearance of the accretion disc is strongly dependent on the value of the superspinar spin in both their shape and frequency shift profile. Apparent extension of the disc grows significantly with the growing spin, while the frequency shift grows with the descending spin. This behaviour differs substantially from the appearance of discs orbiting black holes enabling thus, at least in principle, to distinguish clearly the Kerr superspinars and black holes. In vicinity of a Kerr superspinar the non-escaped photons have to be separated to those captured by the superspinar and those being trapped in its strong gravitational field leading to self-illumination of the disc that could even influence its structure and cause self-reflection effect of radiation of the disc. The amount of trapped photons grows with descending superspinar spin. We thus can expect significant self-illumination effects in the field of Kerr superspinars with near-extreme spin a {approx} 1.

  14. Radionuclide scanning after total knee replacement: correlation with pain and radiolucent lines. A prospective study

    DEFF Research Database (Denmark)

    Duus, B R; Boeckstyns, M; Kjaer, L

    1987-01-01

    The authors examined the relationships among Tc-99m radionuclide bone scan findings, pain, and radiolucent lines in 35 postsurgical knees. Our prospective study included bone scans, as well as radiographic and clinical examination three, seven, and 12 months after knee replacement surgery in 35...... and nonpainful knees, and the degree of isotope uptake did not correlate with the development of radiolucent lines around the prosthetic components....

  15. Actuator disc edge singularity. The key to a revised actuator disc concept and momentum theory

    Energy Technology Data Exchange (ETDEWEB)

    Kuik, G.A.M. van (The Wind Energy Group of the Technical University Eindhoven (NL))

    1989-01-01

    Since the beginning of rotor aerodynamics the actuator disc momentum theory occupies a prominant place in almost any textbook on this subject. Specially in axial flow the theory provides an easy and rather accurate performance prediction. The results first obtained by Lanchester for the induced power of a hovering rotor and the maximum power of a wind turbine are still used as guidelines for complicated calculations. On the other hand, experimental results for propellers are known to deviate systematically (some 10%) from the momentum theory results. This is commonly attributed to the differences between a real rotor and an actuator disc. However, some actuator disc- and actuator strip (the 2-dimensional version) experiments are described in literature, showing the same deviations from momentum theory results. Therefore, apart from the question how representative an actuator disc is for a real rotor, the actuator disc concept itself may be inadequate. This problem is the subject of the work describe here. It will be shown that the classical actuator disc concept ignores discrete forces resulting from a flow singularity at the edge of the disc. The (extended) momentum theory, applied to this actuator strip model, shows a shift of the results towards the experimental data, and for the static case (hover) even a quantitative agreement is obtained. (author) 12 refs.

  16. Impact of depressive symptoms on prosthetic status--results of the study of health in Pomerania (SHIP).

    Science.gov (United States)

    Samietz, Stefanie A; Kindler, Stefan; Schwahn, Christian; Polzer, Ines; Hoffmann, Wolfgang; Kocher, Thomas; Grabe, Hans Jörgen; Mundt, Torsten; Biffar, Reiner

    2013-05-01

    Previous investigations have confirmed that every fifth dental patient suffers from clinically significant depressive symptoms. However, the putative impact of depressive symptoms on the prosthetic status has not been addressed in these studies. The objective of this study was to investigate the association between depressive symptoms and prosthetic status based on data from the Study of Health in Pomerania (SHIP-0). Data from 2,135 participants aged 30 to 59 years were analyzed. A classification (six classes regarding the number and position of missing teeth per jaw) was used to identify the degree of prosthetic status (no/suboptimal/optimal tooth replacement). The presence of depressive symptoms was assessed with a modified version of von Zerssen's complaints scale. Screening for lifetime diagnoses of mental disorders was performed with the Composite International Diagnostic-Screener (CID-S). Multivariable logistic regressions including several confounders were calculated. A significant protective dose-response effect of depressive symptoms on prosthetic status was found only in men for the lower jaw [0-1 depressive symptoms: odds ratio (OR) = 3.84, 95 % confidence interval (CI, 1.65-8.92), p < 0.01; 2-3: OR = 2.87 (CI, 1.22-6.74), p < 0.05; reference, ≥8; adjusted for age, school education, smoking status, household income, marital status, living without a partner, risky alcohol consumption, obesity, diabetes, and physical activity]. There was no such association in women or for the upper jaw. The analyses using the CID-S confirmed these results. In the lower jaw, men with depressive symptoms had a better prosthetic status than men without depressive symptoms suggesting a higher level of concern regarding their personal health. If dentists might have an opportunity to identify men with depressive symptoms they can provide a wide range of treatment options that may enhance patients' self-esteem and contribute to the patient' well-being. Furthermore, depressive

  17. Disc valve for sampling erosive process streams

    Science.gov (United States)

    Mrochek, J.E.; Dinsmore, S.R.; Chandler, E.W.

    1986-01-07

    A four-port disc valve is described for sampling erosive, high temperature process streams. A rotatable disc defining opposed first and second sampling cavities rotates between fired faceplates defining flow passageways positioned to be alternatively in axial alignment with the first and second cavities. Silicon carbide inserts and liners composed of [alpha] silicon carbide are provided in the faceplates and in the sampling cavities to limit erosion while providing lubricity for a smooth and precise operation when used under harsh process conditions. 1 fig.

  18. Static axisymmetric discs and gravitational collapse

    Energy Technology Data Exchange (ETDEWEB)

    Chamorro, A.; Gregory, R.; Stewart, J.M.

    1987-09-08

    Regular static axisymmetric vacuum solutions of Einstein's field equations representing the exterior field of a finite thin disc are found. These are used to describe the slow collapse of a disc-like object. If no conditions are placed on the matter, a naked singularity is formed and the cosmic censorship hypothesis would be violated. Imposition of the weak energy condition, however, prevents slow collapse to a singularity and preserves the validity of this hypothesis. The validity of the hoop conjecture is also discussed.

  19. Cells and Biomaterials for Intervertebral Disc Regeneration

    CERN Document Server

    Grad, Sibylle

    2010-01-01

    Disorders related to the intervertebral disc (IVD) are common causes of morbidity and of severe life quality deterioration. IVD degeneration, although in many cases asymptomatic, is often the origin of painful neck and back diseases. In Western societies IVD related pain and disability account for enormous health care costs as a result of work absenteeism and thus lost production, disability benefits, medical and insurance expenses. Although only a small percentage of patients with disc disorders finally will undergo surgery, spinal surgery has been one of the fastest growing disciplines in th

  20. Design and characterization of a carbon-nanotube-reinforced adhesive coating for piezoelectric ceramic discs

    International Nuclear Information System (INIS)

    Lanzara, G; Chang, F-K

    2009-01-01

    The silver paste electrode of piezoelectric (PZT) ceramic discs has been shown to produce a weak interface bond between a bare PZT and its paste coating under a peeling force. In this work, an investigation was conducted to reinforce the bond with a high density array of oriented carbon nanotube nano-electrodes (CNTs-NEA), between a bare PZT ceramic and a metal substrate. The ensuing design and fabrication of a carbon-nanotube-coated piezoelectric disc (CPZT) is presented along with a study of the bondline integrity of a CPZT mounted on a hosting structure. The CPZT has its electrode silver paste coating replaced with a high density array of CNTs-NEA. Mechanical tests were performed to characterize the shear strength of the bondline between CPZT discs and the substrate. The test results were compared with shear strengths of the bondlines made of pure non-conductive adhesive and adhesive with randomly mixed CNTs. The comparison showed the oriented CNT coating on PZTs could significantly enhance the interfacial shear strength. Through the microscopic examination, it was evident that the ratio between the CNT length (Lc) and the bond thickness (H) significantly influenced the bond strength of CPZT discs. Three major interface microstructure types and their corresponding failure modes for specific Lc/H values were identified. The study also showed that failure did not occur along the interface between the PZT ceramic element and the CNT coating

  1. [Longterm results of cervical arthroplasty with disc prosthesis. A literature review].

    Science.gov (United States)

    Fransen, P; Schils, F

    2014-01-01

    Cervical arthroplasty has now been performed for over 10 years. Despite the large number of implanted artificial discs, the quality of the published studies is weak, and very few report a follow up exceeding two years. We reviewed the literature on cervical total disc replacement, focusing on publications reporting a follow-up of more than two years. The selection of patients, the type of implant and the surgical technique seem to influence greatly the quality of the clinical and radiological results. The occurrence of heterotopic ossifications around the implant seems to be the rule rather than the exception. Wear debris are likely to be observed in the vicinity of the prosthesis. Most long term studies also report a progressive decrease in the range of motion of the prosthesis, although without influence on the clinical evolution. It seems reasonable to say that cervical disc prosthesis is not inferior to discectomy and fusion, and that these implants allow a short term preservation of cervical mobility, but the efficacy in preventing adjacent segment disease or a favourable costleffectiveness ratio have yet to be demonstrated. A more widespread use of cervical disc prosthesis can only be suggested when these questions have been answered by long term follow-up studies.

  2. Quality Assessment of Prosthetic Rehabilitation Using Aesthetic Fixed Restorations

    Directory of Open Access Journals (Sweden)

    Zinovii Ozhohan

    2018-04-01

    Full Text Available The objective of the research was to study and assess the quality of prosthetic treatment using aesthetic fixed restorations. Materials and methods. The study included 79 patients without a comorbidity who underwent prosthetic rehabilitation. All the patients were divided into 3 groups: Group I included 25 patients with metal-plastic restorations; Group II comprised 34 patients with porcelain-fused-to-metal restorations; Group III consisted of 20 patients with a combined occlusal surface of prosthetic restorations. The patients were observed 6 months after prosthetic repair. Only patients with single molar and premolar crowns were examined. Bridge prostheses were not taken into account in order to eliminate the effect of masticatory force redistribution on the abutment crowns. Results. In Group I, 11 (44% patients were satisfied with the results of prosthetic treatment. In Group II, 25 (78.12% patients reported that they were satisfied with their treatment. In Group III, there were 17 (85% patients satisfied with their outcome. However, the patients’ complaints are often subjective and do not fully reflect the objective state of the dentoalveolar system. An objective examination revealed that in indirect restorations, marginal periodontium pathology is typical. Conclusions. Aesthetic fixed restorations with a combined occlusal surface have demonstrated good clinical results, even at long-term follow-up. Combining positive properties of two different construction materials, namely zirconium dioxide and ceramics, they reduce the risk of complications such as marginal periodontium pathology and chipping along the occlusal surface as well as contribute to minimal abrasion of the occlusal surfaces of the antagonistic teeth. We cannot recommend metal-plastic restorations due to their low clinical effectiveness, poor aesthetic qualities as well as a high level of marginal periodontium pathology.

  3. Evaluation of 3D printed anatomically scalable transfemoral prosthetic knee.

    Science.gov (United States)

    Ramakrishnan, Tyagi; Schlafly, Millicent; Reed, Kyle B

    2017-07-01

    This case study compares a transfemoral amputee's gait while using the existing Ossur Total Knee 2000 and our novel 3D printed anatomically scalable transfemoral prosthetic knee. The anatomically scalable transfemoral prosthetic knee is 3D printed out of a carbon-fiber and nylon composite that has a gear-mesh coupling with a hard-stop weight-actuated locking mechanism aided by a cross-linked four-bar spring mechanism. This design can be scaled using anatomical dimensions of a human femur and tibia to have a unique fit for each user. The transfemoral amputee who was tested is high functioning and walked on the Computer Assisted Rehabilitation Environment (CAREN) at a self-selected pace. The motion capture and force data that was collected showed that there were distinct differences in the gait dynamics. The data was used to perform the Combined Gait Asymmetry Metric (CGAM), where the scores revealed that the overall asymmetry of the gait on the Ossur Total Knee was more asymmetric than the anatomically scalable transfemoral prosthetic knee. The anatomically scalable transfemoral prosthetic knee had higher peak knee flexion that caused a large step time asymmetry. This made walking on the anatomically scalable transfemoral prosthetic knee more strenuous due to the compensatory movements in adapting to the different dynamics. This can be overcome by tuning the cross-linked spring mechanism to emulate the dynamics of the subject better. The subject stated that the knee would be good for daily use and has the potential to be adapted as a running knee.

  4. Radiation Source Replacement Workshop

    Energy Technology Data Exchange (ETDEWEB)

    Griffin, Jeffrey W.; Moran, Traci L.; Bond, Leonard J.

    2010-12-01

    This report summarizes a Radiation Source Replacement Workshop in Houston Texas on October 27-28, 2010, which provided a forum for industry and researchers to exchange information and to discuss the issues relating to replacement of AmBe, and potentially other isotope sources used in well logging.

  5. Prosthetic ossicular on middle ear: what look?

    International Nuclear Information System (INIS)

    Cabral, Christiane Pena; Ramos, Frederico Rocha Henriques; Pires, Diego Demolinari; Antunes, Augusto Braga Fernandes; Motta, Emilia Guerra Pinto Coelho; Ribeiro, Marcelo Almeida; Moreira, Wanderval; Diniz, Renata Lopes Furletti Caldeira

    2010-01-01

    The aim of this essay was to demonstrate the normal and pathological CT findings of the post-operative imaging of patients underwent ossicular prosthesis implants. The stapedectomy replaced by prosthesis is considered the 'gold standard' treatment of patients with oval window closure, related to otosclerosis or other inflammatory conditions. Several types of prosthesis are available and the choice depends on the extension of the disease or the surgeon's preferences. Based on extensive literature review, the normal postoperative findings, as well as some surgery inherent complications were described, including among others: perforation of the tympanic membrane, necrosis associated with subluxation/extrusion of the prosthesis, granuloma/cholesteatoma or periprosthetic fibrosis, perilymphatic fistula, facial nerve damage, among other. The knowledge of post-operative and related complications CT findings is extremely useful for head and neck radiologist, but it is essential for an assertive diagnoses a close clinical correlation. (author)

  6. Dutch evidence-based guidelines for amputation and prosthetics of the lower extremity : Rehabilitation process and prosthetics. Part 2

    NARCIS (Netherlands)

    Geertzen, Jan; van der Linde, Harmen; Rosenbrand, Kitty; Conradi, Marcel; Deckers, Jos; Koning, Jan; Rietman, Hans S.; van der Schaaf, Dick; van der Ploeg, Rein; Schapendonk, Johannes; Schrier, Ernst; Duijzentkunst, Rob Smit; Spruit-van Eijk, Monica; Versteegen, Gerbrig; Voesten, Harrie

    2015-01-01

    Background: A structured, multidisciplinary approach in the rehabilitation process after amputation is needed that includes a greater focus on the involvement of both (para)medics and prosthetists. There is considerable variation in prosthetic prescription concerning the moment of initial prosthesis

  7. Parametric modeling of the intervertebral disc space in 3D: application to CT images of the lumbar spine.

    Science.gov (United States)

    Korez, Robert; Likar, Boštjan; Pernuš, Franjo; Vrtovec, Tomaž

    2014-10-01

    Gradual degeneration of intervertebral discs of the lumbar spine is one of the most common causes of low back pain. Although conservative treatment for low back pain may provide relief to most individuals, surgical intervention may be required for individuals with significant continuing symptoms, which is usually performed by replacing the degenerated intervertebral disc with an artificial implant. For designing implants with good bone contact and continuous force distribution, the morphology of the intervertebral disc space and vertebral body endplates is of considerable importance. In this study, we propose a method for parametric modeling of the intervertebral disc space in three dimensions (3D) and show its application to computed tomography (CT) images of the lumbar spine. The initial 3D model of the intervertebral disc space is generated according to the superquadric approach and therefore represented by a truncated elliptical cone, which is initialized by parameters obtained from 3D models of adjacent vertebral bodies. In an optimization procedure, the 3D model of the intervertebral disc space is incrementally deformed by adding parameters that provide a more detailed morphometric description of the observed shape, and aligned to the observed intervertebral disc space in the 3D image. By applying the proposed method to CT images of 20 lumbar spines, the shape and pose of each of the 100 intervertebral disc spaces were represented by a 3D parametric model. The resulting mean (±standard deviation) accuracy of modeling was 1.06±0.98mm in terms of radial Euclidean distance against manually defined ground truth points, with the corresponding success rate of 93% (i.e. 93 out of 100 intervertebral disc spaces were modeled successfully). As the resulting 3D models provide a description of the shape of intervertebral disc spaces in a complete parametric form, morphometric analysis was straightforwardly enabled and allowed the computation of the corresponding

  8. Late prosthetic graft infection after frozen elephant trunk presenting by haemoptysis and positive ¹⁸F-fluorodeoxyglucose-positron emission tomography/computed tomography.

    Science.gov (United States)

    Morjan, Mohammed; Ali, Khaldoun; Harringer, Wolfgang; El-Essawi, Aschraf

    2014-11-01

    In cardiothoracic surgery, prosthetic graft infection represents a diagnostic and therapeutic challenge. Although clinical assessment, imaging techniques and microbiological investigations are helpful, late graft infection can be difficult to identify using classical diagnostic tools. An aggressive surgical approach involving removal and replacement of all prosthetic materials is technically demanding but remains the best strategy to eradicate infection. Herein, we report a case of a late aortic graft infection, after frozen elephant trunk implantation with atypical presentation, diagnosed with (18)F-fluorodeoxyglucose-positron emission tomography and treated successfully through a radical surgical strategy. This case emphasizes the emerging diagnostic role of positron emission tomography and encourages the adoption of an aggressive surgical approach. © The Author 2014. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.

  9. Transcatheter, valve-in-valve transapical aortic and mitral valve implantation, in a high risk patient with aortic and mitral prosthetic valve stenoses

    Directory of Open Access Journals (Sweden)

    Harish Ramakrishna

    2015-01-01

    Full Text Available Transcatheter valve implantation continues to grow worldwide and has been used principally for the nonsurgical management of native aortic valvular disease-as a potentially less invasive method of valve replacement in high-risk and inoperable patients with severe aortic valve stenosis. Given the burden of valvular heart disease in the general population and the increasing numbers of patients who have had previous valve operations, we are now seeing a growing number of high-risk patients presenting with prosthetic valve stenosis, who are not potential surgical candidates. For this high-risk subset transcatheter valve delivery may be the only option. Here, we present an inoperable patient with severe, prosthetic valve aortic and mitral stenosis who was successfully treated with a trans catheter based approach, with a valve-in-valve implantation procedure of both aortic and mitral valves.

  10. Analysis of Interrelationships among Voluntary and Prosthetic Leg Joint Parameters Using Cyclograms.

    Science.gov (United States)

    Jasni, Farahiyah; Hamzaid, Nur Azah; Mohd Syah, Nor Elleeiana; Chung, Tze Y; Abu Osman, Noor Azuan

    2017-01-01

    The walking mechanism of a prosthetic leg user is a tightly coordinated movement of several joints and limb segments. The interaction among the voluntary and mechanical joints and segments requires particular biomechanical insight. This study aims to analyze the inter-relationship between amputees' voluntary and mechanical coupled leg joints variables using cyclograms. From this analysis, the critical gait parameters in each gait phase were determined and analyzed if they contribute to a better powered prosthetic knee control design. To develop the cyclogram model, 20 healthy able-bodied subjects and 25 prosthesis and orthosis users (10 transtibial amputees, 5 transfemoral amputees, and 10 different pathological profiles of orthosis users) walked at their comfortable speed in a 3D motion analysis lab setting. The gait parameters (i.e., angle, moment and power for the ankle, knee and hip joints) were coupled to form 36 cyclograms relationship. The model was validated by quantifying the gait disparities of all the pathological walking by analyzing each cyclograms pairs using feed-forward neural network with backpropagation. Subsequently, the cyclogram pairs that contributed to the highest gait disparity of each gait phase were manipulated by replacing it with normal values and re-analyzed. The manipulated cyclograms relationship that showed highest improvement in terms of gait disparity calculation suggested that they are the most dominant parameters in powered-knee control. In case of transfemoral amputee walking, it was identified using this approach that at each gait sub-phase, the knee variables most responsible for closest to normal walking were: knee power during loading response and mid-stance, knee moment and knee angle during terminal stance phase, knee angle and knee power during pre-swing, knee angle at initial swing, and knee power at terminal swing. No variable was dominant during mid-swing phase implying natural pendulum effect of the lower limb between

  11. Analysis of Interrelationships among Voluntary and Prosthetic Leg Joint Parameters Using Cyclograms

    Directory of Open Access Journals (Sweden)

    Nur Azah Hamzaid

    2017-04-01

    Full Text Available The walking mechanism of a prosthetic leg user is a tightly coordinated movement of several joints and limb segments. The interaction among the voluntary and mechanical joints and segments requires particular biomechanical insight. This study aims to analyze the inter-relationship between amputees' voluntary and mechanical coupled leg joints variables using cyclograms. From this analysis, the critical gait parameters in each gait phase were determined and analyzed if they contribute to a better powered prosthetic knee control design. To develop the cyclogram model, 20 healthy able-bodied subjects and 25 prosthesis and orthosis users (10 transtibial amputees, 5 transfemoral amputees, and 10 different pathological profiles of orthosis users walked at their comfortable speed in a 3D motion analysis lab setting. The gait parameters (i.e., angle, moment and power for the ankle, knee and hip joints were coupled to form 36 cyclograms relationship. The model was validated by quantifying the gait disparities of all the pathological walking by analyzing each cyclograms pairs using feed-forward neural network with backpropagation. Subsequently, the cyclogram pairs that contributed to the highest gait disparity of each gait phase were manipulated by replacing it with normal values and re-analyzed. The manipulated cyclograms relationship that showed highest improvement in terms of gait disparity calculation suggested that they are the most dominant parameters in powered-knee control. In case of transfemoral amputee walking, it was identified using this approach that at each gait sub-phase, the knee variables most responsible for closest to normal walking were: knee power during loading response and mid-stance, knee moment and knee angle during terminal stance phase, knee angle and knee power during pre-swing, knee angle at initial swing, and knee power at terminal swing. No variable was dominant during mid-swing phase implying natural pendulum effect of the

  12. Relationship of condylar position to disc position and morphology

    Energy Technology Data Exchange (ETDEWEB)

    Incesu, L.; Taskaya-Yilmaz, N. E-mail: nergizy@omu.edu.tr; Oeguetcen-Toller, M.; Uzun, E

    2004-09-01

    Introduction/objective: The purpose of this study was to assess whether condylar position, as depicted by magnetic resonance imaging, was an indicator of disc morphology and position. Methods and material: One hundred and twenty two TMJs of 61 patients with temporomandibular joint disorder were examined. Condylar position, disc deformity and degree of anterior disc displacement were evaluated by using magnetic resonance imaging. Results and discussion: Posterior condyle position was found to be the main feature of temporomandibular joints with slight and moderate anterior disc displacement. No statistical significance was found between the condylar position, and reducing and nonreducing disc positions. On the other hand, superior disc position was found to be statistically significant for centric condylar position. Conclusion: It was concluded that posterior condyle position could indicate anterior disc displacement whereas there was no relation between the position of condyle and the disc deformity.

  13. Imaging characteristics of noncontained migrating disc fragment and cyst

    International Nuclear Information System (INIS)

    Eerens, I.; Demaerel, P.; Haven, F.; Wilms, G.; Loon, J. van; Calenbergh, F. van

    2001-01-01

    The purpose of this article is to review less common presentations of degenerative disc disease on MR imaging. The images of eight patients were retrospectively analyzed. Six of them had transligamentous (or noncontained) disc herniations, the fragments of which were located in the posterior epidural space in three of them. One patient had a transdural disc fragment and one patient had a disc cyst. The cyst was located in the ventrolateral epidural space. On T2-weighted images, the migrated disc fragment returned a higher signal than the disc of origin in 6 of 7 patients. The disc cyst returned a signal similar to that of cerebrospinal fluid. The MR appearances of disc fragments can be puzzling, particularly if they are located in the posterior epidural space. It is important to recognize the abnormalities in order to differentiate them from less common lesions such as hematoma, abscess and neurinoma. (orig.)

  14. Imaging characteristics of noncontained migrating disc fragment and cyst

    Energy Technology Data Exchange (ETDEWEB)

    Eerens, I.; Demaerel, P.; Haven, F.; Wilms, G. [Dept. of Radiology, University Hospitals, Leuven (Belgium); Loon, J. van; Calenbergh, F. van [Dept. of Neurosurgery, University Hospitals, Leuven (Belgium)

    2001-05-01

    The purpose of this article is to review less common presentations of degenerative disc disease on MR imaging. The images of eight patients were retrospectively analyzed. Six of them had transligamentous (or noncontained) disc herniations, the fragments of which were located in the posterior epidural space in three of them. One patient had a transdural disc fragment and one patient had a disc cyst. The cyst was located in the ventrolateral epidural space. On T2-weighted images, the migrated disc fragment returned a higher signal than the disc of origin in 6 of 7 patients. The disc cyst returned a signal similar to that of cerebrospinal fluid. The MR appearances of disc fragments can be puzzling, particularly if they are located in the posterior epidural space. It is important to recognize the abnormalities in order to differentiate them from less common lesions such as hematoma, abscess and neurinoma. (orig.)

  15. Current antibiotic management of prosthetic joint infections in Italy: the 'Udine strategy'.

    Science.gov (United States)

    Bassetti, Matteo; Cadeo, Barbara; Villa, Giovanni; Sartor, Assunta; Cainero, Vanni; Causero, Araldo

    2014-09-01

    The rate of prosthetic joint infections followed and cured at our institution is constantly increasing, in line with epidemiological data from the recent literature. This is probably related to the greater number of knee and hip prostheses implanted every year. For intermediate and late infections, only the two-stage approach is applied, as this demonstrates the best outcome in our experience. Particular attention is paid to microbiological isolation of the pathogen: multiple samples of tissue are collected during the interventions, and kept in culture for a longer period of time than usual. Sonication of prosthetic devices is used to enhance the sensitivity and specificity of the microbiological cultures. Histological examination influences surgical choices either towards implantation of a new prosthesis or replacement of the spacer. An empirical antibiotic backbone of a glycopeptide/lipopeptide and rifampicin is chosen, due to the leading role of Gram-positive bacteria in this setting and the high incidence of methicillin resistance in our centre (>30%), followed by an antibiotic regimen containing linezolid. If specific risk factors are present, an anti-Gram-negative drug is added to the regimen. Duration of therapy depends upon the approach that is chosen, usually being 6 weeks when the prosthesis is removed. Despite at the moment being limited by its small sample size, data from our experience confirms that our empirical approach may represent a valid choice during the early phase of treatment, by keeping linezolid for a step-down therapy of shorter duration (4 weeks). © The Author 2014. Published by Oxford University Press on behalf of the British Society for Antimicrobial Chemotherapy. All rights reserved. For Permissions, please e-mail: journals.permissions@oup.com.

  16. Evaluation of a musculoskeletal model with prosthetic knee through six experimental gait trials.

    Science.gov (United States)

    Kia, Mohammad; Stylianou, Antonis P; Guess, Trent M

    2014-03-01

    Knowledge of the forces acting on musculoskeletal joint tissues during movement benefits tissue engineering, artificial joint replacement, and our understanding of ligament and cartilage injury. Computational models can be used to predict these internal forces, but musculoskeletal models that simultaneously calculate muscle force and the resulting loading on joint structures are rare. This study used publicly available gait, skeletal geometry, and instrumented prosthetic knee loading data [1] to evaluate muscle driven forward dynamics simulations of walking. Inputs to the simulation were measured kinematics and outputs included muscle, ground reaction, ligament, and joint contact forces. A full body musculoskeletal model with subject specific lower extremity geometries was developed in the multibody framework. A compliant contact was defined between the prosthetic femoral component and tibia insert geometries. Ligament structures were modeled with a nonlinear force-strain relationship. The model included 45 muscles on the right lower leg. During forward dynamics simulations a feedback control scheme calculated muscle forces using the error signal between the current muscle lengths and the lengths recorded during inverse kinematics simulations. Predicted tibio-femoral contact force, ground reaction forces, and muscle forces were compared to experimental measurements for six different gait trials using three different gait types (normal, trunk sway, and medial thrust). The mean average deviation (MAD) and root mean square deviation (RMSD) over one gait cycle are reported. The muscle driven forward dynamics simulations were computationally efficient and consistently reproduced the inverse kinematics motion. The forward simulations also predicted total knee contact forces (166Nphysiological motor control patterns during gait. Consequently, the simulations did not accurately predict medial/lateral tibio-femoral force distribution and muscle activation timing. Copyright

  17. Solid angle subtended by two circular discs

    International Nuclear Information System (INIS)

    Gilly, Louis.

    1978-09-01

    Methods of calculation of solid angles, subtended by two circular discs are analysed. Calculus are methodically classified as follow: series development Legendre polynomes, defined integral, elliptic integrals, Bessel integrals, multiple integrals, Monte Carlo method, electrostatic analogy. Applications in Nuclear Physics are added as examples. List of numeric tables completes bibliography [fr

  18. Frictional Torque on a Rotating Disc

    Science.gov (United States)

    Mungan, Carl E.

    2012-01-01

    Resistance to motion often includes a dry frictional term independent of the speed of an object and a fluid drag term varying linearly with speed in the viscous limit. (At higher speeds, quadratic drag can also occur.) Here, measurements are performed for an aluminium disc mounted on bearings that is given an initial twist and allowed to spin…

  19. Fusion around cervical disc prosthesis: case report.

    NARCIS (Netherlands)

    Bartels, R.H.M.A.; Donk, R.

    2005-01-01

    OBJECTIVE AND IMPORTANCE: Cervical arthroplasty is a relatively new method to maintain motion after cervical anterior discectomy. Two cases are presented in which bony fusion occurred around a cervical disc prosthesis. CLINICAL PRESENTATION: A 30-year-old man and a 49-year-old woman underwent a

  20. Can Exercise Positively Influence the Intervertebral Disc?

    NARCIS (Netherlands)

    Belavý, Daniel L.; Albracht, Kirsten; Bruggemann, Gert Peter; Vergroesen, Pieter Paul A; van Dieën, Jaap H.

    2016-01-01

    To better understand what kinds of sports and exercise could be beneficial for the intervertebral disc (IVD), we performed a review to synthesise the literature on IVD adaptation with loading and exercise. The state of the literature did not permit a systematic review; therefore, we performed a

  1. Radiographic identification of ingested disc batteries

    International Nuclear Information System (INIS)

    Maves, M.D.

    1986-01-01

    Recently, the hazards by posed the accidental ingestion and impaction of small disc batteries have been widely publicized in the medical and lay press. These foreign bodies, when lodged in the esophagus, leak a caustic solution of 26 to 45% sodium or potassium hydroxide which can cause a burn injury to the esophagus in a very short period of time. Because of the considerable clinical morbidity and mortality from this foreign body, it becomes imperative for the radiologist to quickly and accurately identify disc batteries on plain radiographs. This communication offers a series of radiologic signs important in the identification of disc batteries demonstrate a double density shadow due to the bilaminar structure of the battery. On lateral view, the edges of most disc batteries are round and again present a step-off at the junction of the cathode and anode. These findings are differentiated from the more common esophageal foreign body of a coin which does not have a double density on frontal projection, has a much sharper edge and no visible stepoff. (orig.)

  2. Kinematic structures in galactic disc simulations

    NARCIS (Netherlands)

    Roca-F� brega, S.; Romero-Gómez, M.; Figueras, F.; Antoja Castelltort, Teresa; Valenzuela, O.; Henney, W.J.; Torres-Peimbert, S.

    2011-01-01

    N-body and test particle simulations have been used to characterize the stellar streams in the galactic discs of Milky Way type galaxies. Tools such as the second and third order moments of the velocity ellipsoid and clustering methods -EM-WEKA and FoF- allow characterizing these kinematic

  3. Geršgorin discs revisited

    Czech Academy of Sciences Publication Activity Database

    Fiedler, Miroslav; Hall, F.J.; Marsli, R.

    2013-01-01

    Roč. 438, č. 1 (2013), s. 598-603 ISSN 0024-3795 Institutional support: RVO:67985807 Keywords : geometric multiplicity * algebra ic multiplicity * Geršgorin disc Subject RIV: BA - General Mathematics Impact factor: 0.983, year: 2013

  4. Angiogenesis in the degeneration of the lumbar intervertebral disc

    OpenAIRE

    David, Gh; Ciurea, AV; Iencean, SM; Mohan, A

    2010-01-01

    The goal of the study is to show the histological and biochemical changes that indicate the angiogenesis of the intervertebral disc in lumbar intervertebral disc hernia and the existence of epidemiological correlations between these changes and the risk factors of lumbar intervertebral disc hernia, as well as the patient's quality of life (QOL). We have studied 50 patients aged between 18 and 73 years old, who have undergone lumbar intervertebral disc hernia surgery, making fibroblast growth ...

  5. On the diversity and statistical properties of protostellar discs

    Science.gov (United States)

    Bate, Matthew R.

    2018-04-01

    We present results from the first population synthesis study of protostellar discs. We analyse the evolution and properties of a large sample of protostellar discs formed in a radiation hydrodynamical simulation of star cluster formation. Due to the chaotic nature of the star formation process, we find an enormous diversity of young protostellar discs, including misaligned discs, and discs whose orientations vary with time. Star-disc interactions truncate discs and produce multiple systems. Discs may be destroyed in dynamical encounters and/or through ram-pressure stripping, but reform by later gas accretion. We quantify the distributions of disc mass and radii for protostellar ages up to ≈105 yr. For low-mass protostars, disc masses tend to increase with both age and protostellar mass. Disc radii range from of order 10 to a few hundred au, grow in size on time-scales ≲ 104 yr, and are smaller around lower mass protostars. The radial surface density profiles of isolated protostellar discs are flatter than the minimum mass solar nebula model, typically scaling as Σ ∝ r-1. Disc to protostar mass ratios rarely exceed two, with a typical range of Md/M* = 0.1-1 to ages ≲ 104 yr and decreasing thereafter. We quantify the relative orientation angles of circumstellar discs and the orbit of bound pairs of protostars, finding a preference for alignment that strengths with decreasing separation. We also investigate how the orientations of the outer parts of discs differ from the protostellar and inner disc spins for isolated protostars and pairs.

  6. Physical Limitations to Tissue Engineering of Intervertabral Disc Cells

    OpenAIRE

    Kobayashi, Shigeru; Baba, Hisatoshi; Takeno, Kenichi; Miyazaki, Tsuyoshi; Meir, Adam; Urban, Jill

    2010-01-01

    There is increasing interest in the using biological methods to repair degenerate discs. Biological repair depends on the disc maintaining a population of viable and active cells. Adequate nutrition of the disc influences the outcome of such therapies and, hence, must be considered to be a crucial parameter. Therefore, it is very important to maintain an appropriate physicochemical environment to achieve successful disc repair by biological methods and tissue engineering procedures.

  7. Positional and morphologic changes of the temporomandibular joint disc using magnetic resonance imaging

    International Nuclear Information System (INIS)

    Ahn, Hyoun Suk; Cho, Su Beom; Koh, Kwang Joon

    2001-01-01

    To evaluate displacement and morphologic changes of the temporomandibular joint (TMJ) disc in patient with internal derangement using magnetic resonance imaging (MRI). One hundred and forty five MR images of TMJs in 73 patients were evaluated. Positional and morphologic changes of the TMJ disc were assessed. Lateral or medial disc displacement was also evaluated on cornal images. Among 63 discs with anterior disc displacement, 37 discs were assessed as a biconcave disc and 21 as a deformed disc. Rotational disc displacement was observed in 35 disc. Anteromedial disc displacement was observed in 29 discs, and anterolateral direction in 6 discs. Among 35 rotational displacement, 5 biconcave discs and 21 deformed discs were observed. Rotational and sideways displacement of TMJ discs were found to be common and an important aspect of internal derangement. This study also suggests that sagittal and coronal images of the TMJ have complementary abilities for an assessment of joint abnormality

  8. Grain size segregation in debris discs

    Science.gov (United States)

    Thebault, P.; Kral, Q.; Augereau, J.-C.

    2014-01-01

    Context. In most debris discs, dust grain dynamics is strongly affected by stellar radiation pressure. Because this mechanism is size-dependent, we expect dust grains to be spatially segregated according to their sizes. However, because of the complex interplay between radiation pressure, grain processing by collisions, and dynamical perturbations, this spatial segregation of the particle size distribution (PSD) has proven difficult to investigate and quantify with numerical models. Aims: We propose to thoroughly investigate this problem by using a new-generation code that can handle some of the complex coupling between dynamical and collisional effects. We intend to explore how PSDs behave in both unperturbed discs at rest and in discs pertubed by planetary objects. Methods: We used the DyCoSS code to investigate the coupled effect of collisions, radiation pressure, and dynamical perturbations in systems that have reached a steady-state. We considered two setups: a narrow ring perturbed by an exterior planet, and an extended disc into which a planet is embedded. For both setups we considered an additional unperturbed case without a planet. We also investigated the effect of possible spatial size segregation on disc images at different wavelengths. Results: We find that PSDs are always spatially segregated. The only case for which the PSD follows a standard dn ∝ s-3.5ds law is for an unperturbed narrow ring, but only within the parent-body ring itself. For all other configurations, the size distributions can strongly depart from such power laws and have steep spatial gradients. As an example, the geometrical cross-section of the disc is very rarely dominated by the smallest grains on bound orbits, as it is expected to be in standard PSDs in sq with q ≤ -3. Although the exact profiles and spatial variations of PSDs are a complex function of the set-up that is considered, we are still able to derive some reliable results that will be useful for image or SED

  9. Prognosis of intervertebral disc loss from diagnosis of degenerative disc disease

    Science.gov (United States)

    Li, S.; Lin, A.; Tay, K.; Romano, W.; Osman, Said

    2015-03-01

    Degenerative Disc Disease (DDD) is one of the most common causes of low back pain, and is a major factor in limiting the quality of life of an individual usually as they enter older stages of life, the disc degeneration reduces the shock absorption available which in turn causes pain. Disc loss is one of the central processes in the pathogenesis of DDD. In this study, we investigated whether the image texture features quantified from magnetic resonance imaging (MRI) could be appropriate markers for diagnosis of DDD and prognosis of inter-vertebral disc loss. The main objective is to use simple image based biomarkers to perform prognosis of spinal diseases using non-invasive procedures. Our results from 65 subjects proved the higher success rates of the combination marker compared to the individual markers and in the future, we will extend the study to other spine regions to allow prognosis and diagnosis of DDD for a wider region.

  10. Initial Clinical Evaluation of the Modular Prosthetic Limb

    Directory of Open Access Journals (Sweden)

    Briana N. Perry

    2018-03-01

    Full Text Available The Modular Prosthetic Limb (MPL was examined for its feasibility and usability as an advanced, dexterous upper extremity prosthesis with surface electromyography (sEMG control in with two individuals with below-elbow amputations. Compared to currently marketed prostheses, the MPL has a greater number of sequential and simultaneous degrees of motion, as well as wrist modularity, haptic feedback, and individual digit control. The MPL was successfully fit to a 33-year-old with a trans-radial amputation (TR01 and a 30-year-old with a wrist disarticulation amputation (TR02. To preserve anatomical limb length, we adjusted the powered degrees of freedom of wrist motion between users. Motor training began with practicing sEMG and pattern recognition control within the virtual integration environment (VIE. Prosthetic training sessions then allowed participants to complete a variety of activities of daily living with the MPL. Training and Motion Control Accuracy scores quantified their ability to consistently train and execute unique muscle-to-motion contraction patterns. Each user also completed one prosthetic functional metric—the Southampton Hand Assessment Procedure (SHAP for TR01 and the Jebsen-Taylor Hand Function Test (JHFT for TR02. Haptic feedback capabilities were integrated for TR01. TR01 achieved 95% accuracy at 84% of his VIE sessions. He demonstrated improved scores over a year of prosthetic training sessions, ultimately achieving simultaneous control of 13 of the 17 (76% attempted motions. His performance on the SHAP improved from baseline to final assessment with an increase in number of tasks achieved. TR01 also used vibrotactile sensors to successfully discriminate between hard and soft objects being grasped by the MPL hand. TR02 demonstrated 95% accuracy at 79% of his VIE sessions. He demonstrated improved scores over months of prosthetic training sessions, however there was a significant drop in scores initially following a mid

  11. Could wind replace nuclear?

    International Nuclear Information System (INIS)

    2017-01-01

    This article aims at assessing the situation produced by a total replacement of nuclear energy by wind energy, while facing consumption demand at any moment, notably in December. The authors indicate the evolution of the French energy mix during December 2016, and the evolution of the rate between wind energy production and the sum of nuclear and wind energy production during the same month, and then give briefly some elements regarding necessary investments in wind energy to wholly replace nuclear energy. According to them, such a replacement would be ruinous

  12. Time Localisation of Surface Defects on Optical Discs

    DEFF Research Database (Denmark)

    Odgaard, Peter Fogh; Wickerhauser, M.V.

    Many have experienced problems with their Compact Disc player when a disc with a scratch or a finger print is tried played. One way to improve the playability of discs with such a defect, is to locate the defect in time and then handle it in a special way. As a consequence this time localisation...

  13. Time Localisation of Surface Defects on Optical Discs

    DEFF Research Database (Denmark)

    Odgaard, Peter Fogh; Wickerhauser, M.V.

    2004-01-01

    Many have experienced problems with their Compact Disc Player when a disc with a scratch or a fingerprint is tried played. One way to improve the playability of discs with such a defect, is to locate the defect in time and then handle it in a special way. As a consequence this time localization...

  14. Analysis of an Assemblage of Discs Employing Interactive Graphics.

    Science.gov (United States)

    1980-12-01

    facilitate the program’s efficiency. Indeed, the ulsabilitv of tie distinct element method is pred icated on ef f ic ielt Irogramming techniques...paragraphs. Any subsequent user of DISC should not necessarily feel bound to this scheme. 33. At the outset of writing DISC, it was decided that a disc

  15. On the illumination of neutron star accretion discs

    Science.gov (United States)

    Wilkins, D. R.

    2018-03-01

    The illumination of the accretion disc in a neutron star X-ray binary by X-rays emitted from (or close to) the neutron star surface is explored through general relativistic ray tracing simulations. The applicability of the canonical suite of relativistically broadened emission line models (developed for black holes) to discs around neutron stars is evaluated. These models were found to describe well emission lines from neutron star accretion discs unless the neutron star radius is larger than the innermost stable orbit of the accretion disc at 6 rg or the disc is viewed at high inclination, above 60° where shadowing of the back side of the disc becomes important. Theoretical emissivity profiles were computed for accretion discs illuminated by hotspots on the neutron star surfaces, bands of emission and emission by the entirety of the hot, spherical star surface and in all cases, the emissivity profile of the accretion disc was found to be well represented by a single power law falling off slightly steeper than r-3. Steepening of the emissivity index was found where the emission is close to the disc plane and the disc can appear truncated when illuminated by a hotspot at high latitude. The emissivity profile of the accretion disc in Serpens X-1 was measured and found to be consistent with a single unbroken power law with index q=3.5_{-0.4}^{+0.3}, suggestive of illumination by the boundary layer between the disc and neutron star surface.

  16. A method for quantitative measurement of lumbar intervertebral disc structures

    DEFF Research Database (Denmark)

    Tunset, Andreas; Kjær, Per; Samir Chreiteh, Shadi

    2013-01-01

    There is a shortage of agreement studies relevant for measuring changes over time in lumbar intervertebral disc structures. The objectives of this study were: 1) to develop a method for measurement of intervertebral disc height, anterior and posterior disc material and dural sac diameter using MR...

  17. Vortex ring state by full-field actuator disc model

    Energy Technology Data Exchange (ETDEWEB)

    Soerensen, J.N.; Shen, W.Z.; Munduate, X. [DTU, Dept. of Energy Engineering, Lyngby (Denmark)

    1997-08-01

    One-dimensional momentum theory provides a simple analytical tool for analysing the gross flow behavior of lifting propellers and rotors. Combined with a blade-element strip-theory approach, it has for many years been the most popular model for load and performance predictions of wind turbines. The model works well at moderate and high wind velocities, but is not reliable at small wind velocities, where the expansion of the wake is large and the flow field behind the rotor dominated by turbulent mixing. This is normally referred to as the turbulent wake state or the vortex ring state. In the vortex ring state, momentum theory predicts a decrease of thrust whereas the opposite is found from experiments. The reason for the disagreement is that recirculation takes place behind the rotor with the consequence that the stream tubes past the rotor becomes effectively chocked. This represents a condition at which streamlines no longer carry fluid elements from far upstream to far downstream, hence one-dimensional momentum theory is invalid and empirical corrections have to be introduced. More sophisticated analytical or semi-analytical rotor models have been used to describe stationary flow fields for heavily loaded propellers. In recent years generalized actuator disc models have been developed, but up to now no detailed computations of the turbulent wake state or the vortex ring state have been performed. In the present work the phenomenon is simulated by direct simulation of the Navier-Stokes equations, where the influence of the rotor on the flow field is modelled simply by replacing the blades by an actuator disc with a constant normal load. (EG) 13 refs.

  18. CT in diagnosis of recurrent vertebral disc hernias after preceding lumbar disc prolapse surgery

    International Nuclear Information System (INIS)

    Burval, S.; Nekula, J.; Vaverka, M.; Veliskova, J.

    1992-01-01

    20 patients with recurrent symptoms following operations for disc prolapse and resistant to treatment were studied by CT, using plain and enhanced images. The results have been analysed. In 10 patients a recurrence of disc prolapse was diagnosed, and this was confirmed surgically in 8 cases. In 2 patients there was epidural scarring. The findings indicate that differential diagnosis between scarring and recurring prolapse can by accurately made by this technique. (orig.) [de

  19. The life cycles of Be viscous decretion discs: fundamental disc parameters of 54 SMC Be stars

    Science.gov (United States)

    Rímulo, L. R.; Carciofi, A. C.; Vieira, R. G.; Rivinius, Th; Faes, D. M.; Figueiredo, A. L.; Bjorkman, J. E.; Georgy, C.; Ghoreyshi, M. R.; Soszyński, I.

    2018-05-01

    Be stars are main-sequence massive stars with emission features in their spectrum, which originates in circumstellar gaseous discs. Even though the viscous decretion disc model can satisfactorily explain most observations, two important physical ingredients, namely the magnitude of the viscosity (α) and the disc mass injection rate, remain poorly constrained. The light curves of Be stars that undergo events of disc formation and dissipation offer an opportunity to constrain these quantities. A pipeline was developed to model these events that use a grid of synthetic light curves, computed from coupled hydrodynamic and radiative transfer calculations. A sample of 54 Be stars from the OGLE survey of the Small Magellanic Cloud (SMC) was selected for this study. Because of the way our sample was selected (bright stars with clear disc events), it likely represents the densest discs in the SMC. Like their siblings in the Galaxy, the mass of the disc in the SMC increases with the stellar mass. The typical mass and angular momentum loss rates associated with the disc events are of the order of ˜10-10 M⊙ yr-1 and ˜5 × 1036 g cm2 s-2, respectively. The values of α found in this work are typically of a few tenths, consistent with recent results in the literature and with the ones found in dwarf novae, but larger than current theory predicts. Considering the sample as a whole, the viscosity parameter is roughly two times larger at build-up ( = 0.63) than at dissipation ( = 0.26). Further work is necessary to verify whether this trend is real or a result of some of the model assumptions.

  20. Spontaneous Resolution of Optic Disc Pit Maculopathy

    Directory of Open Access Journals (Sweden)

    Koushik Tripathy

    2017-06-01

    Full Text Available I read with interest the article reporting spontaneous resolution of optic disc pit maculopathy in a boy.1 Though the presence of an optic disc pit and associated macular involvement is undoubted in the presented case, the provided optical coherence tomography (OCT does not clearly show typical intraretinal schisis (Figure 1B1 at multiple retinal levels which may communicate with the pit. Instead, it shows a sub-internal limiting membrane (sub-ILM cavity. Such cavities are known to occur following the resolution of sub-ILM bleed due to various cause including Valsalva retinopathy,2 Terson syndrome, and also in some retinitis3 cases.4 In fact, some of these cavities may simulate a neurosensory retinal detachment or central serous chorioretinopathy on cursory clinical examination.5 To confirm that the features of the current patient1 are indeed related to the optic disc pit, it is necessary for the authors to provide an OCT scan which shows a connection of the presented cavity with the optic disc pit. Also, clear OCT scans of the fovea, both at presentation and at final follow-up would help our understanding of the visual recovery of the patient. The interval between the presenting (28 June 2012 OCT and final OCT (30 Nov 2012 is 5 months and not 6 months as described in the manuscript. For an effective comparison, both the presenting and final OCT scans should have been taken using either horizontal or vertical orientation over the macula. Though the spontaneous resolution of optic disc pit maculopathy is possible, visual recovery in usually unlikely and in such cases an alternate diagnosis needs to be excluded.