WorldWideScience

Sample records for prostheses

  1. Microbial biofilms on silicone facial prostheses

    NARCIS (Netherlands)

    Ariani, Nina

    2015-01-01

    Facial disfigurements can result from oncologic surgery, trauma and congenital deformities. These disfigurements can be rehabilitated with facial prostheses. Facial prostheses are usually made of silicones. A problem of facial prostheses is that microorganisms can colonize their surface. It is hard

  2. Magnetic resonance imaging of breast prostheses

    African Journals Online (AJOL)

    G5

    and the commonest cause of replacement of the prosthesis. Older prostheses contained silicone gel. Rupture of these prostheses, although asymptomatic in most patients, has been associated with collagen vascular disorders and chronic fatigue syndrome. However more current data disputes any of these associations.

  3. Protective prostheses during radiation therapy

    International Nuclear Information System (INIS)

    Poole, T.S.; Flaxman, N.A.

    1986-01-01

    Current applications and complications in the use of radiotherapy for the treatment of oral malignancy are reviewed. Prostheses are used for decreasing radiation to vital structures not involved with the lesion but located in the field of radiation. With a program of oral hygiene and proper dental care, protective prostheses can help decrease greatly the morbidity seen with existing radiotherapy regimens

  4. Implant-level prostheses in the edentulous maxilla: a comparison with conventional abutment-level prostheses after 5 years of use.

    Science.gov (United States)

    Hjalmarsson, Lars; Smedberg, Jan-Ivan; Pettersson, Mattias; Jemt, Torsten

    2011-01-01

    Long-term comparisons of frameworks at the implant or abutment level are not available, and knowledge of the clinical function of cobalt-chromium (Co-Cr) alloy frameworks is limited. Primarily, the aim of this study was to compare the 5-year clinical performance of frameworks with or without abutment connections to implants. Secondly, the outcomes of prostheses made from Co-Cr alloy with porcelain veneers to those made of commercially pure titanium (CP Ti) with acrylic veneers were compared. The test groups comprised patients treated with screw-retained fixed prostheses made at the implant level according to the Cresco method in either dental porcelain-veneered Co-Cr alloy (n = 15) or acrylic-veneered CP Ti (n = 25). A control group of 40 randomly selected patients were provided with prostheses made at the standard abutment level in CP Ti with acrylic veneers. For all patients, clinical and radiologic 5-year data were retrospectively collected and evaluated. Five-year implant cumulative survival rates (CSRs) were 98.6% and 97.6% for test and control groups, respectively (P > .05). No major differences in bone level were demonstrated between the groups after 5 years (P > .05). Significantly more complications occurred in the test groups compared to the control group (P level prostheses made of porcelain-veneered Co-Cr or acrylic-veneered CP Ti seem comparable to acrylic-veneered titanium prostheses made at the standard abutment level regarding implant CSR and bone levels. However, more complications were registered in implant-level prostheses compared to the standard abutment-level prostheses.

  5. Computer-aided dental prostheses construction using reverse engineering.

    Science.gov (United States)

    Solaberrieta, E; Minguez, R; Barrenetxea, L; Sierra, E; Etxaniz, O

    2014-01-01

    The implementation of computer-aided design/computer-aided manufacturing (CAD/CAM) systems with virtual articulators, which take into account the kinematics, constitutes a breakthrough in the construction of customised dental prostheses. This paper presents a multidisciplinary protocol involving CAM techniques to produce dental prostheses. This protocol includes a step-by-step procedure using innovative reverse engineering technologies to transform completely virtual design processes into customised prostheses. A special emphasis is placed on a novel method that permits a virtual location of the models. The complete workflow includes the optical scanning of the patient, the use of reverse engineering software and, if necessary, the use of rapid prototyping to produce CAD temporary prostheses.

  6. Characterizing the Mechanical Properties of Running-Specific Prostheses

    Science.gov (United States)

    Beck, Owen N.; Taboga, Paolo; Grabowski, Alena M.

    2016-01-01

    The mechanical stiffness of running-specific prostheses likely affects the functional abilities of athletes with leg amputations. However, each prosthetic manufacturer recommends prostheses based on subjective stiffness categories rather than performance based metrics. The actual mechanical stiffness values of running-specific prostheses (i.e. kN/m) are unknown. Consequently, we sought to characterize and disseminate the stiffness values of running-specific prostheses so that researchers, clinicians, and athletes can objectively evaluate prosthetic function. We characterized the stiffness values of 55 running-specific prostheses across various models, stiffness categories, and heights using forces and angles representative of those measured from athletes with transtibial amputations during running. Characterizing prosthetic force-displacement profiles with a 2nd degree polynomial explained 4.4% more of the variance than a linear function (prunning 3 m/s and 6 m/s (10°-25°) compared to neutral (0°) (pRunning-specific prostheses should be tested under the demands of the respective activity in order to derive relevant characterizations of stiffness and function. In all, our results indicate that when athletes with leg amputations alter prosthetic model, height, and/or sagittal plane alignment, their prosthetic stiffness profiles also change; therefore variations in comfort, performance, etc. may be indirectly due to altered stiffness. PMID:27973573

  7. Fabrication of biosynthetic vascular prostheses by 193-nm excimer laser radiation

    Science.gov (United States)

    Husinsky, Wolfgang; Csek, Ch.; Bartel, A.; Grabenwoeger, M.; Fitzal, F.; Wolner, Ernst

    1998-05-01

    This study was undertaken to investigate the feasibility of transmural capillary ingrowth into the inner surface of biosynthetic vascular prostheses (OmniflowTM) through perforations created by an excimer-laser, thus inducing an endothelial cell coverage. The biosynthetic vascular prostheses (10 cm length, 6 mm (phi) ) were perforated with an excimer laser ((phi) of the holes 50 - 100 micrometer, distance 4 mm) and implanted into the carotid arteries of 8 sheep. The laser tissue interaction process of 193 nm radiation ensures minimal thermal damage to the prostheses. They were compared to untreated OmniflowTM prostheses implanted at the contralateral side. Three months after implantation the prostheses were explanted and evaluated by gross morphology, histological examination and scanning electron microscopy. Scanning electron microscopy showed endothelial cells in the midgraft portion of all perforated prostheses, whereas collagen fibers, fibrin meshwork and activated platelets formed the inner layer in 6 out of 8 untreated OmniflowTM prostheses. It can be concluded, that spontaneous endothelialization of biosynthetic vascular prostheses can be achieved by transmural capillary ingrowth through perforations in the wall of the prostheses in an experimental sheep model.

  8. Cobalt release and complications resulting from the use of dental prostheses

    DEFF Research Database (Denmark)

    Al-Imam, Hiba; Benetti, Ana R.; Özhayat, Esben B.

    2016-01-01

    of the functional prostheses released cobalt, whereas this was observed in 24 of 32 non-functional prostheses. None of the patients had contact allergy to cobalt. Of the 66 patients, 11 showed signs of inflammation of the oral mucosa, 2 had oral candidiasis, 16 had ill-fitting prostheses, and all had insufficient...... oral hygiene. CONCLUSIONS: Dental prostheses released cobalt during the fabrication stages, but not 1-5 years after insertion. No allergic reactions were observed. Signs of inflammation were related to candidiasis, insufficient oral hygiene, and ill-fitting prostheses....

  9. REDUCED THROMBOGENICITY OF VASCULAR PROSTHESES BY COATING WITH ADP-ASE

    NARCIS (Netherlands)

    VANDERLEI, B; ROBINSON, PH; BAKKER, WW; Bartels, H.

    1992-01-01

    In this pilot study ADP-ase coated polyurethane (PL) vascular prostheses and noncoated (control) PU vascular prostheses (all vascular prostheses: ID 1.5 mm, length 1,5 cm) were implanted into the carotid artery of the rabbit to test wheter ADP-ase might function as an adequate anti-thrombogenic

  10. Lactobacilli : Important in biofilm formation on voice prostheses

    NARCIS (Netherlands)

    Buijssen, Kevin J. D. A.; Harmsen, Hermie J. M.; van der Mei, Henny C.; Busscher, Henk J.; van der Laan, Bernard F. A. M.

    OBJECTIVE: We sought to identify bacterial strains responsible for biofilm formation on silicone rubber voice prostheses. STUDY DESIGN: We conducted an analysis of the bacterial population in biofilms on used silicone rubber voice prostheses by using new microbiological methods. METHODS: Two

  11. 3D-printed upper limb prostheses : a review

    NARCIS (Netherlands)

    ten Kate, J; Smit, G.; Breedveld, P.

    2017-01-01

    Goal: This paper aims to provide an overview with quantitative information of existing 3D-printed upper limb prostheses. We will identify the benefits and drawbacks of 3D-printed devices to enable improvement of current devices based on the demands of prostheses users. Methods: A review was

  12. Longitudinal research on the oral environment of elderly wearing fixed or removable prostheses.

    Science.gov (United States)

    Tanaka, Junko; Tanaka, Masahiro; Kawazoe, Takayoshi

    2009-04-01

    The purpose of this study was to investigate oral environmental risk factors involved in caries incidence in the elderly. We investigated the relationship between the oral environment factors of the elderly with both fixed prostheses and removable prostheses at baseline and at follow-up and examined time-course changes of each oral environmental factor by prosthesis type. The subject group consisted 11 elderly patients with fixed prostheses and 11 who wore removable prostheses. We examined oral environmental factors by saliva tests. Five oral environmental factors were examined: the stimulated salivary flow rate, buffering capacity, and the counts of mutans streptococci (SM), lactobacilli (LB), and Candida (CA). We compared these factors for subjects with fixed prostheses and those wearing removable prostheses at baseline and at follow-up. Furthermore, 3-year changes in the factors of each oral environment were compared and evaluated. Significant differences were observed between the two groups in the salivary microbial counts of SM and LB at baseline and at follow-up. The LB counts increased in the Denture group during the 3-year period and significant differences were noted. We found that fixed prostheses are less cariogenic, and removable prostheses cause an increase in the cariogenic bacterial count. Regarding time-course changes by the type of prosthesis, the LB count tended to increase in the subjects with removable prostheses. The risk of caries due to a fixed prosthesis may be lower than that of removable prostheses.

  13. Heat generated by knee prostheses.

    Science.gov (United States)

    Pritchett, James W

    2006-01-01

    Temperature sensors were placed in 50 knees in 25 patients who had one or both joints replaced. Temperature recordings were made before walking, after walking, and after cycling. The heat generated in healthy, arthritic, and replaced knees was measured. The knee replacements were done using eight different prostheses. A rotating hinge knee prosthesis generated a temperature increase of 7 degrees C in 20 minutes and 9 degrees C in 40 minutes. An unconstrained ceramic femoral prosthesis articulating with a polyethylene tibial prosthesis generated a temperature increase of 4 degrees C compared with a healthy resting knee. The other designs using a cobalt-chrome alloy and high-density polyethylene had temperature increases of 5 degrees-7 degrees C with exercise. Frictional heat generated in a prosthetic knee is not immediately dissipated and may result in wear, creep, and other degenerative processes in the high-density polyethylene. Extended periods of elevated temperature in joints may inhibit cell growth and perhaps contribute to adverse performance via bone resorption or component loosening. Prosthetic knees generate more heat with activity than healthy or arthritic knees. More-constrained knee prostheses generate more heat than less-constrained prostheses. A knee with a ceramic femoral component generates less heat than a knee with the same design using a cobalt-chromium alloy.

  14. MECHANICAL HEART-VALVE PROSTHESES - SOUND LEVEL AND RELATED COMPLAINTS

    NARCIS (Netherlands)

    LAURENS, RRP; WIT, HP; EBELS, T

    In a randomised study, we investigated the sound production of mechanical heart valve prostheses and the complaints related to this sound. The CarboMedics, Bjork-Shiley monostrut and StJude Medical prostheses were compared. A-weighted levels of the pulse-like sound produced by the prosthesis were

  15. Dual jaw treatment of edentulism using implant-supported monolithic zirconia fixed prostheses.

    Science.gov (United States)

    Altarawneh, Sandra; Limmer, Bryan; Reside, Glenn J; Cooper, Lyndon

    2015-01-01

    This case report describes restoration of the edentulous maxilla and mandible with implant supported fixed prostheses using monolithic zirconia, where the incisal edges and occluding surfaces were made of monolithic zirconia. Edentulism is a debilitating condition that can be treated with either a removable or fixed dental prosthesis. The most common type of implant-supported fixed prosthesis is the metal acrylic (hybrid), with ceramo-metal prostheses being used less commonly in complete edentulism. However, both of these prostheses designs are associated with reported complications of screw loosening or fracture and chipping of acrylic resin and porcelain. Monolithic zirconia implant-supported fixed prostheses have the potential for reduction of such complications. In this case, the CAD/CAM concept was utilized in fabrication of maxillary and mandibular screw-retained implant-supported fixed prostheses using monolithic zirconia. Proper treatment planning and execution coupled with utilizing advanced technologies contributes to highly esthetic results. However, long-term studies are required to guarantee a satisfactory long-term outcome of this modality of treatment. This case report describes the clinical and technical procedures involved in fabrication of maxillary and mandibular implant-supported fixed prostheses using monolithic zirconia as a treatment of edentulism, and proposes the possible advantages associated with using monolithic zirconia in eliminating dissimilar interfaces in such prostheses that are accountable for the most commonly occurring technical complication for these prostheses being chipping and fracture of the veneering material. © 2015 Wiley Periodicals, Inc.

  16. Esthetic, functional, and prosthetic outcomes with implant-retained finger prostheses.

    Science.gov (United States)

    Aydin, Cemal; Nemli, Secil Karakoca; Yilmaz, Handan

    2013-04-01

    Traumatic amputation of fingers results in a serious impairment of hand function and affects the psychological status of the patients. The implant-retained finger prostheses are an alternative treatment. The aim of this case report is to represent the use of osseointegrated implants for retention of finger prostheses in a patient with amputated thumb and index finger. Dental implants were placed in the residual bone of the fingers using two-stage surgery. Custom-made attachments were used to provide retention between implants and silicone prostheses. Prosthetic fingernails were made of composite resin material. After 6 months, implants were clinically successful, and the patient was satisfied with the appearance and the function of the prostheses. The complications of broken prosthetic nail and mild discoloration were observed. Reconstruction of amputated fingers with implant-retained prosthesis is a worthwhile treatment providing esthetic, functional, and psychological benefits, although some complications might be experienced. Clinical relevance Implant-retained finger prostheses are an acceptable treatment modality for patients with amputated fingers. Evaluating implant prognosis, functional results and prosthetic results of the patients are necessary to address the benefits and complications of the treatment.

  17. Oral cavity anaerobic pathogens in biofilm formation on voice prostheses

    NARCIS (Netherlands)

    Bertl, Kristina; Zijnge, Vincent; Zatorska, Beata; Leonhard, Matthias; Schneider-Stickler, Berit; Harmsen, Hermie J. M.

    BACKGROUND: A polymerase chain reaction (PCR)-based method has been used to identify oral anaerobic pathogens in biofilms on voice prostheses. The purpose of the present study was to determine the location of those pathogens inside the biofilms. METHODS: Biofilms of 15 voice prostheses were sampled

  18. [The costs for different voice prostheses depending on the lifetime].

    Science.gov (United States)

    Schuldt, T; Ovari, A; Dommerich, S

    2013-06-01

    Voice prostheses are available in different types of architecture und from different producers. Especially the ones with antifungal properties are characterized by a high pricing. The aim of this paper is to check, whether these prices are reflected by the prosthesis life time.A Benchmarking with usage of mean lifetime and prosthesis costs. Comparing Provox 1, Provox 2, Provox Vega, Provox ActiValve, ESKA-Herrmann, Blom Singer Classic, Phonax, Blom Singer Advantage.The voice prosthesis Provox 1 offers the best price-lifetime-ratio (1.0). It's 6.7-times higher than the one of the Provox ActiValve (0.15). In addition, the classic prostheses Provox 2 (0.53), Blom Singer Classic (0.54) and ESKA-Herrmann (0.72) offer a good ratio compared to Provox 1, too.The mean lifetime of the voice prostheses do not reflect the pricing. The Provox 1 offers the best ratio and should be used as a reference in pricing the prostheses. © Georg Thieme Verlag KG Stuttgart · New York.

  19. International comparative evaluation of knee replacement with fixed or mobile-bearing posterior-stabilized prostheses.

    Science.gov (United States)

    Graves, Stephen; Sedrakyan, Art; Baste, Valborg; Gioe, Terence J; Namba, Robert; Martínez Cruz, Olga; Stea, Susanna; Paxton, Elizabeth; Banerjee, Samprit; Isaacs, Abby J; Robertsson, Otto

    2014-12-17

    Posterior-stabilized total knee prostheses were introduced to address instability secondary to loss of posterior cruciate ligament function, and they have either fixed or mobile bearings. Mobile bearings were developed to improve the function and longevity of total knee prostheses. In this study, the International Consortium of Orthopaedic Registries used a distributed health data network to study a large cohort of posterior-stabilized prostheses to determine if the outcome of a posterior-stabilized total knee prosthesis differs depending on whether it has a fixed or mobile-bearing design. Aggregated registry data were collected with a distributed health data network that was developed by the International Consortium of Orthopaedic Registries to reduce barriers to participation (e.g., security, proprietary, legal, and privacy issues) that have the potential to occur with the alternate centralized data warehouse approach. A distributed health data network is a decentralized model that allows secure storage and analysis of data from different registries. Each registry provided data on mobile and fixed-bearing posterior-stabilized prostheses implanted between 2001 and 2010. Only prostheses associated with primary total knee arthroplasties performed for the treatment of osteoarthritis were included. Prostheses with all types of fixation were included except for those with the rarely used reverse hybrid (cementless tibial and cemented femoral components) fixation. The use of patellar resurfacing was reported. The outcome of interest was time to first revision (for any reason). Multivariate meta-analysis was performed with linear mixed models with survival probability as the unit of analysis. This study includes 137,616 posterior-stabilized knee prostheses; 62% were in female patients, and 17.6% had a mobile bearing. The results of the fixed-effects model indicate that in the first year the mobile-bearing posterior-stabilized prostheses had a significantly higher hazard

  20. [Morphological features of utilization intraperitoneal double-sided prostheses in inguinoplasty in dogs].

    Science.gov (United States)

    de Andrade, Luiz Carlos; Ceneviva, Reginaldo; Coutinho-Netto, Joaquim; Silva Júnior, Orlando de Castro e; dos Santos, José Sebastião; Sukeda, Daniel Hirochi

    2009-10-01

    To asses the morphological features of the behavior of a double-sided prostheses using inguinoplasty laparotomy in dogs with latex side turned to the visceras. Twenty dogs were divided into two groups of 10 and submitted into infraumbilical laparotomy with double-sided prostheses fixed in an inguinal area and in the other side area a control prostheses of polipropilene (PPL). Macroscopics itens were studied on the 14th and 28th day post-operatory, and they were related to obstruction and intestinal fistulas, encystation, fusion and especially sticker. The microscopic analysis covered the inflammatory process in its acute, chronic and restored phase Infectious process, obstruction or intestinal fistula did not happen. The prostheses presented good accommodation and incorporation. The stickers happened with more prevalent and intensity with the PPL (p0,05). The double-sided prostheses in its parietal side adds the advantages of the incorporation's potential to the noticed material with PPL to the biocompatibility from the latex in its visceral side. The little distance between the PPL disc and the edge of the double-sided prostheses (2 cm) allied to its sticking with just five staples is not enough to avoid gaps, through which the epíploon migrated towards to the inflammatory process provoked by PPL in the parietal side.

  1. Cementless Hydroxyapatite Coated Hip Prostheses

    Science.gov (United States)

    Herrera, Antonio; Mateo, Jesús; Gil-Albarova, Jorge; Lobo-Escolar, Antonio; Ibarz, Elena; Gabarre, Sergio; Más, Yolanda

    2015-01-01

    More than twenty years ago, hydroxyapatite (HA), calcium phosphate ceramics, was introduced as a coating for cementless hip prostheses. The choice of this ceramic is due to its composition being similar to organic apatite bone crystals. This ceramic is biocompatible, bioactive, and osteoconductive. These qualities facilitate the primary stability and osseointegration of implants. Our surgical experience includes the implantation of more than 4,000 cementless hydroxyapatite coated hip prostheses since 1990. The models implanted are coated with HA in the acetabulum and in the metaphyseal area of the stem. The results corresponding to survival and stability of implants were very satisfactory in the long-term. From our experience, HA-coated hip implants are a reliable alternative which can achieve long term survival, provided that certain requirements are met: good design selection, sound choice of bearing surfaces based on patient life expectancy, meticulous surgical technique, and indications based on adequate bone quality. PMID:25802848

  2. Cementless Hydroxyapatite Coated Hip Prostheses

    Directory of Open Access Journals (Sweden)

    Antonio Herrera

    2015-01-01

    Full Text Available More than twenty years ago, hydroxyapatite (HA, calcium phosphate ceramics, was introduced as a coating for cementless hip prostheses. The choice of this ceramic is due to its composition being similar to organic apatite bone crystals. This ceramic is biocompatible, bioactive, and osteoconductive. These qualities facilitate the primary stability and osseointegration of implants. Our surgical experience includes the implantation of more than 4,000 cementless hydroxyapatite coated hip prostheses since 1990. The models implanted are coated with HA in the acetabulum and in the metaphyseal area of the stem. The results corresponding to survival and stability of implants were very satisfactory in the long-term. From our experience, HA-coated hip implants are a reliable alternative which can achieve long term survival, provided that certain requirements are met: good design selection, sound choice of bearing surfaces based on patient life expectancy, meticulous surgical technique, and indications based on adequate bone quality.

  3. Movement characteristics of upper extremity prostheses during basic goal-directed tasks

    NARCIS (Netherlands)

    Bouwsema, Hanneke; van der Sluis, Corry K.; Bongers, Raoul M.

    Background: After an upper limb amputation a prosthesis is often used to restore the functionality. However, the frequency of prostheses use is generally low. Movement kinematics of prostheses use might suggest origins of this low use. The aim of this study was to reveal movement patterns of

  4. 3D-printed upper limb prostheses: a review.

    Science.gov (United States)

    Ten Kate, Jelle; Smit, Gerwin; Breedveld, Paul

    2017-04-01

    This paper aims to provide an overview with quantitative information of existing 3D-printed upper limb prostheses. We will identify the benefits and drawbacks of 3D-printed devices to enable improvement of current devices based on the demands of prostheses users. A review was performed using Scopus, Web of Science and websites related to 3D-printing. Quantitative information on the mechanical and kinematic specifications and 3D-printing technology used was extracted from the papers and websites. The overview (58 devices) provides the general specifications, the mechanical and kinematic specifications of the devices and information regarding the 3D-printing technology used for hands. The overview shows prostheses for all different upper limb amputation levels with different types of control and a maximum material cost of $500. A large range of various prostheses have been 3D-printed, of which the majority are used by children. Evidence with respect to the user acceptance, functionality and durability of the 3D-printed hands is lacking. Contrary to what is often claimed, 3D-printing is not necessarily cheap, e.g., injection moulding can be cheaper. Conversely, 3D-printing provides a promising possibility for individualization, e.g., personalized socket, colour, shape and size, without the need for adjusting the production machine. Implications for rehabilitation Upper limb deficiency is a condition in which a part of the upper limb is missing as a result of a congenital limb deficiency of as a result of an amputation. A prosthetic hand can restore some of the functions of a missing limb and help the user in performing activities of daily living. Using 3D-printing technology is one of the solutions to manufacture hand prostheses. This overview provides information about the general, mechanical and kinematic specifications of all the devices and it provides the information about the 3D-printing technology used to print the hands.

  5. Fabrication of low cost soft tissue prostheses with the desktop 3D printer.

    Science.gov (United States)

    He, Yong; Xue, Guang-huai; Fu, Jian-zhong

    2014-11-27

    Soft tissue prostheses such as artificial ear, eye and nose are widely used in the maxillofacial rehabilitation. In this report we demonstrate how to fabricate soft prostheses mold with a low cost desktop 3D printer. The fabrication method used is referred to as Scanning Printing Polishing Casting (SPPC). Firstly the anatomy is scanned with a 3D scanner, then a tissue casting mold is designed on computer and printed with a desktop 3D printer. Subsequently, a chemical polishing method is used to polish the casting mold by removing the staircase effect and acquiring a smooth surface. Finally, the last step is to cast medical grade silicone into the mold. After the silicone is cured, the fine soft prostheses can be removed from the mold. Utilizing the SPPC method, soft prostheses with smooth surface and complicated structure can be fabricated at a low cost. Accordingly, the total cost of fabricating ear prosthesis is about $30, which is much lower than the current soft prostheses fabrication methods.

  6. Fracture analysis of randomized implant-supported fixed dental prostheses

    Science.gov (United States)

    Esquivel-Upshaw, Josephine F.; Mehler, Alex; Clark, Arthur E.; Neal, Dan; Anusavice, Kenneth J.

    2014-01-01

    Objective Fractures of posterior fixed dental all-ceramic prostheses can be caused by one or more factors including prosthesis design, flaw distribution, direction and magnitude of occlusal loading, and nature of supporting infrastructure (tooth root/implant), and presence of adjacent teeth. This clinical study of implant-supported, all-ceramic fixed dental prostheses, determined the effects of (1) presence of a tooth distal to the most distal retainer; (2) prosthesis loading either along the non-load bearing or load bearing areas; (3) presence of excursive contacts or maximum intercuspation contacts in the prosthesis; and (4) magnitude of bite force on the occurrence of veneer ceramic fracture. Methods 89 implant-supported FDPs were randomized as either a three-unit posterior metal-ceramic (Au-Pd-Ag alloy and InLine POM, Ivoclar, Vivadent) FDP or a ceramic-ceramic (ZirCAD and ZirPress, Ivoclar, Vivadent) FDP. Two implants (Osseospeed, Dentsply) and custom abutments (Atlantis, Dentsply) supported these FDPs, which were cemented with resin cement (RelyX Universal Cement). Baseline photographs were made with markings of teeth from maximum intercuspation (MI) and excursive function. Patients were recalled at 6 months and 1 to 3 years. Fractures were observed, their locations recorded, and images compared with baseline photographs of occlusal contacts. Conclusion No significant relationship exists between the occurrence of fracture and: (1) the magnitude of bite force; (2) a tooth distal to the most distal retainer; and (3) contacts in load-bearing or non-load-bearing areas. However, there was a significantly higher likelihood of fracture in areas with MI contacts only. Clinical Significance This clinical study demonstrates that there is a need to evaluate occlusion differently with implant-supported prostheses than with natural tooth supported prostheses because of the absence of a periodontal ligament. Implant supported prostheses should have minimal occlusion and

  7. An in vivo comparative study of the e-polytetrafluoroethylene vascular prostheses: Vitaflon and Gore-Tex.

    Science.gov (United States)

    Dobrova, N B; Gorodkov, A J; Sidorenko, E S; Schekhter, A B; Baquey, C

    1999-12-01

    A comparative study was performed in order to validate new Russian e-PTFE vascular prostheses Vitaflon (St. Petersburg, Russia). The Gore-Tex prostheses were chosen as a referential model. The prostheses were implanted in the venous and arterial positions in 13 dog experiments. After the implantation time was over a comprehensive histological and histochemical examination of excized specimens was performed. It was demonstrated that there is no difference in healing and functional properties between the two studied prostheses. Copyright 1999 Kluwer Academic Publishers

  8. A biodegradable gentamicin-hydroxyapatite-coating for infection prophylaxis in cementless hip prostheses

    NARCIS (Netherlands)

    Neut, D.; Dijkstra, R. J. B.; Thompson, J. I.; Kavanagh, C.; van der Mei, H. C.; Busscher, H. J.

    2015-01-01

    A degradable, poly (lactic-co-glycolic acid) (PLGA), gentamicin-loaded prophylactic coating for hydroxyapatite (HA)-coated cementless hip prostheses is developed with similar antibacterial efficacy as offered by gentamicin-loaded cements for fixing traditional, cemented prostheses in bone. We

  9. Articulation prostheses made of polymers which are improved by ionizing radiations

    International Nuclear Information System (INIS)

    Gaussens, G.; Nicaise, M.; Tran, K.O.

    1981-10-01

    Articulation prostheses for the human body are generally made of the couple very high molecular weight polyethylene-special steels. Polyethylene properties are modified by ionizing radiations: creep resistance is improved and friction coefficient is decreased. Modifications are controlled by the choice of radiation dose and dose rate. Wear tests have been made on hip prostheses [fr

  10. [Significance of various implantate localizations of Sparks prostheses, experimental studies in rats].

    Science.gov (United States)

    Brieler, H S; Parwaresch, R; Thiede, A

    1976-01-01

    Our investigations show that Sparks prostheses after subcutaneous implantation are suitable for vascular grafting. At the end of the organization period the connective tissue becomes strong, and after the third and fourth weeks collagenous and elastic fibers can be seen. Ten weeks after s.c. implantation, collagenous fibers predominate. After this the Sparks prostheses can be used as a vascular graft. Intraperitoneal implantation, however, shows a histologically different picture with characteristic findings: only fat cells can be observed, a strong granulation tissue with elastic and collagenous fibers is not present. After intraperitoneal implantation Sparks prostheses are therefore unsuitable for vascular grafts.

  11. Candida albicans in patients with oronasal communication and obturator prostheses

    OpenAIRE

    MATTOS, Beatriz Silva Câmara; SOUSA, Andréa Alves de; MAGALHÃES, Marina Helena C. G. de; ANDRÉ, Marcia; BRITO E DIAS, Reinaldo

    2009-01-01

    Patients using obturator prostheses often present denture-induced stomatitis. In order to detect the presence of oral Candida albicans in patients with oronasal communications and to evaluate the effectiveness of a topical antifungal treatment, cytological smears obtained from the buccal and palatal mucosa of 10 adult patients, and from the nasal acrylic surface of their obturator prostheses were examined. A therapeutic protocol comprising the use of oral nystatin (Mycostatin®) and prosthesis...

  12. A need for a more user-centered design in body powered prostheses

    NARCIS (Netherlands)

    Hichert, M.; Plettenburg, D.H.; Vardy, A.N.; Will, Wendy; Scheme, Erik

    2014-01-01

    Users of body powered prostheses (BPP) complain about too high operating forces, leading to pain and/or fatigue during or after prosthetic operation. In the worst case nerve and vessel damage can occur [1, 2], leading to nonuse of prostheses. Smit et al. investigated cable forces and displacements

  13. A Study of Ossiculoplasty in Chronic Otitis Media using different types of Prostheses

    Directory of Open Access Journals (Sweden)

    Parthapratim Laha

    2013-12-01

    Full Text Available Abstract Introduction: A wide range of prostheses, autologus and synthetic are available for use these days. Ideally, the ossicular reconstruction prosthesis should be biocompatible, safe, easy to handle and capable of efficient sound transmission. Aim and objectives: To study operative ease and post-operative hearing results in patients undergoing ossiculoplasty with different types of prostheses. Materials and methods: A prospective randomized study of 25 patients with Chronic Otitis Media, undergoing ossiculoplasty was conducted at Command Hospital, Kolkata. Tragal cartilage was used in 05 patients, conchal cartilage in 05, refashioned incus in 05, hydroxyapatite in 05 and titanium prostheses in 05 patients. Subjects with mixed hearing loss, multiple co-morbidities and revision surgeries were excluded. Hearing assessment was done by pure tone audiometry pre-operatively and 04 and 12 weeks postoperatively. Results were analyzed statistically. Results: Using tragal or conchal cartilage took almost equal time as autologus incus. Using synthetic material saved time. Titanium prosthesis gives maximum surgical ease. Post-operative air-bone gap reduction within 20 dB was seen in all, irrespective of type of prostheses.  Conclusion: Surgical ease is considerably better with titanium prostheses; however hearing results are equally good in all.

  14. [Posturographic study of total prostheses in the leg. Apropos of 88 patients examined].

    Science.gov (United States)

    Lord, G; Gentaz, R; Gagey, P M; Baron, J B

    1976-01-01

    By suppressing certain articular sensory receptors, the reconstructive surgery of joints using total prostheses modifies tonic postural activity and, by this means, alters the regulation of balance in the subjects of operation. This doubtless explains certain discrepancies between the apparently excellent results in respect of joint movement and muscle strength and poor utilisation of the joint in every day life (instability, use of sticks or failure to use the joint in walking). Drawing on the experience and basic work of specialists in posture, the authors have undertaken a study of tonic postural activity in patients who had received a total prosthesis in the lower limb, both from the clinical aspect and by graphic measurement using an electronic apparatus, the statokinesiometer. Fourteen normal subjects were tested to calibrate the apparatus and 8 patients suffering from established osteoarthritis of the hip were studied as controls. Analysis of tonic postural activity was made in 66 patients who had received total prostheses in the lower limb. The results showed significant disturbance in balance in ankle prostheses, minimal disturbance in knee prostheses and not significant disturbance in hip prostheses. Certain therapeutic implications are derived from this study.

  15. High cable forces deteriorate pinch force control in voluntary-closing body-powered prostheses

    NARCIS (Netherlands)

    Hichert, M.; Abbink, D.A.; Kyberd, P.J.; Plettenburg, D.H.

    2017-01-01

    Background It is generally asserted that reliable and intuitive control of upper-limb prostheses requires adequate feedback of prosthetic finger positions and pinch forces applied to objects. Bodypowered prostheses (BPPs) provide the user with direct proprioceptive feedback. Currently available

  16. Magnetic resonance imaging in patients with heart valve prostheses

    International Nuclear Information System (INIS)

    Bachmann, R.; Juengehuelsing, M.; Schicha, H.; Deutsch, H.J.; Sechtem, U.; Hilger, H.H.

    1991-01-01

    Artifical valve prostheses are often regarded as a contraindication for magnetic resonance imaging (MRI), although preliminary in vitro studies suggested, that patients with these metallic implants might safely undergo MR examination. This study reports on the experience with a group of 89 patients with 100 heart valve prostheses who were examined by spin-echo MR and gradient-echo MR. MR examination was performed in all patients without complications. The spin-echo sequence showed advantages in the depiction of anatomical structures like paravalvular abcesses. Anatomical structures adjacent to the artificial valve were clearly visivle and the metal components of the valves showes no or only small artifacts. Artifacts were accentuated when using gradient-echo sequences. Gradient-echo sequences provided valuable information regarding the presence of valvular insufficiency. Physiological valvular regurgitation was easy to differentiate from pathological paravalvular or transvalvular regurgitation. These results demonstrate that patients with artificial valve prostheses can be imaged by MR without risk and that prosthesis-induced artifacts do no interfere with image interpretation. (orig.) [de

  17. Reflections on the present and future of upper limb prostheses.

    Science.gov (United States)

    Farina, Dario; Amsüss, Sebastian

    2016-01-01

    Despite progress in research and media attention on active upper limb prostheses, presently the most common commercial upper limb prosthetic devices are not fundamentally different from solutions offered almost one century ago. Limited information transfer for both control and sensory-motor integration and challenges in socket technology have been major obstacles. By analysing the present state-of-the-art and academic achievements, we provide our opinion on the future of upper limb prostheses. We believe that surgical procedures for muscle reinnervation and osseointegration will become increasingly clinically relevant; muscle electrical signals will remain the main clinical means for prosthetic control; and chronic electrode implants, first in muscles (control), then in nerves (sensory feedback), will become viable clinical solutions. After decades of suspended clinically relevant progress, it is foreseeable that a new generation of upper limb prostheses will enter the market in the near future based on such advances, thereby offering substantial clinical benefit for patients.

  18. Recovering a "Disfigured"¹ Face: Cosmesis in the Everyday Use of Facial Prostheses

    NARCIS (Netherlands)

    Yaron, Gili; Widdershoven, G.A.M.; Slatman, Jenny

    2017-01-01

    Prosthetic devices that replace an absent body part are generally considered to be either cosmetic or functional. Functional prostheses aim to restore (some degree of) lost physical functioning. Cosmetic prostheses attempt to restore a “normal” appearance to bodies that lack (one or more) limbs by

  19. Clinical Management of Implant Prostheses in Patients with Bruxism

    Science.gov (United States)

    Komiyama, Osamu; Lobbezoo, Frank; De Laat, Antoon; Iida, Takashi; Kitagawa, Tsuyoshi; Murakami, Hiroshi; Kato, Takao; Kawara, Misao

    2012-01-01

    There is general agreement that excessive stress to the bone-implant interface may result in implant overload and failure. Early failure of the implant due to excessive loading occurs shortly after uncovering the implant. Excess load on a final restoration after successful implant integration can result in physical failure of the implant structure. Many clinicians believe that overload of dental implants is a risk factor for vertical peri-implant bone loss and/or may be detrimental for the suprastructure in implant prostheses. It has been documented that occlusal parafunction, such as, bruxism (tooth grinding and clenching) affects the outcome of implant prostheses, but there is no evidence for a causal relation between the failures and overload of dental implants. In spite of this lack of evidence, often metal restorations are preferred instead of porcelain for patients in whom bruxism is presumed on the basis of tooth wear. The purpose of this paper is to discuss the importance of the occlusal scheme used in implant restorations for implant longevity and to suggest a clinical approach and occlusal materials for implant prostheses in order to prevent complications related to bruxism. PMID:22701484

  20. Nuclear medicine and prostheses

    International Nuclear Information System (INIS)

    Bordenave, L.; Baquey, Ch.

    2004-01-01

    Whatever the bio-material, prosthesis or medical device concerned, from design to experimental then clinical validation, nuclear medicine (NM) techniques offer a unique opportunity in all indications, (in vitro diagnosis, in vivo diagnosis and therapy) to investigate, assess and predict the behaviour of the device, qualitatively and quantitatively. All research fields involving prostheses and their constitutive biomaterials may take advantage of NM. In order to review published works, one can analyze provided data according to two strategies: an upright one related to medical and surgical specialties that integrate NM and a more horizontal one, that is to describe what kind of contribution is brought by such investigations. The latter approach was preferred in our review. We discuss and illustrate benefits of NM in the following indications: as an in vitro tool, as an in vivo tool for the diagnosis i) of device integration in recipient, ii) of functional outcome after use or implantation, iii) and predictive assessment of undesirable side effects, iv) of occurrence of complications associated to the device implantation, v) of a new therapy efficiency; finally as in vivo tool of therapy. Tissue engineering and regenerative medicine domains with stem cell potential as well as that of medical device associated with vigilance are new fields in basic research and clinical assessment that seem increasingly promising for the nuclear physician and to which NM could and would contribute from molecule to integrated system in order to improve knowledge and achievement of prostheses. (author)

  1. Should silicone prostheses be considered for specimen banking? A pilot study into their use for human biomonitoring.

    Science.gov (United States)

    Allan, Ian J; Bæk, Kine; Kringstad, Alfhild; Roald, Helge E; Thomas, Kevin V

    2013-09-01

    Persistent organic pollutant (POP) biomonitoring in humans is challenging and generally carried out using blood, breast milk or adipose tissue, with concentrations normalised to the lipid content of the sample matrix. The goal of this cross-sectional pilot study was to evaluate the validity and feasibility of explanted silicone prostheses as a matrix for persistent organic pollutant biomonitoring in humans. We postulate that pollutant concentrations in silicone prostheses inserted in the body will equilibrate with that in the body over time and provide a measure of the overall body burden. This study included silicone prostheses from 22 female patients of the Colosseum clinic (Oslo, Norway) collected between September 2010 and April 2012. Absorption of chlorinated and brominated POPs into silicone prostheses during implantation was observed. Relative levels of the different contaminants measured in prostheses were in agreement with those from serum and breast milk analyses from the general Norwegian population. The comparison of serum and breast milk-based literature data with prosthesis concentrations transposed into lipid-normalised concentrations supports the validity of the prosthesis measurements. The median of relative percent differences between measurements with replicate silicone prostheses from 11 patients was below 30%. Observed increases in prosthesis concentrations with patients' age were found to be very similar to literature data from studies of the Norwegian population. Silicone prostheses therefore represent a promising matrix for the biomonitoring of nonpolar and non-ionic pollutants in humans. Sample accessibility and body burden representativeness of the silicone prostheses suggest that specimen banking should be initiated. © 2013.

  2. Progress in the clinical development and utilization of vision prostheses: an update

    Directory of Open Access Journals (Sweden)

    Brandli A

    2016-05-01

    Full Text Available Alice Brandli, Chi D Luu, Robyn H Guymer, Lauren N Ayton Centre for Eye Research Australia, Department of Surgery (Ophthalmology, The University of Melbourne, Royal Victorian Eye and Ear Hospital, Melbourne, VIC, Australia Abstract: Vision prostheses, or “bionic eyes”, are implantable medical bionic devices with the potential to restore rudimentary sight to people with profound vision loss or blindness. In the past two decades, this field has rapidly progressed, and there are now two commercially available retinal prostheses in the US and Europe, and a number of next-generation devices in development. This review provides an update on the development of these devices and a discussion on the future directions for the field. Keywords: vision prostheses, bionic eye, vision restoration, blindness, medical bionics, retinitis pigmentosa

  3. Laser vibrometer measurements and middle ear prostheses

    Science.gov (United States)

    Flock, Stephen T.; Dornhoffer, John; Ferguson, Scott

    1997-05-01

    One of us has developed an improved partial ossicular replacement prosthesis that is easier to implant and, based on pilot clinical measurements, results in better high-frequency hearing as compared to patients receiving one of the alternative prostheses. It is hypothesized that the primary reason for this is because of the relatively light weight (about 25 mg) and low compliance of the prosthesis, which could conceivably result in better high frequency vibrational characteristics. The purpose of our initial work was to develop an instrument suitable for objectively testing the vibrational characteristics of prostheses. We have developed a laser based device suitable for measuring the vibrational characteristics of the oval window or other structures of the middle ear. We have tested this device using a piezoelectric transducer excited at audio frequencies, as well as on the oval window in human temporal bones harvested from cadavers. The results illustrate that it is possible to non-invasively monitor the vibrational characteristics of anatomic structures with a very inexpensive photonic device.

  4. Manufacturing implant supported auricular prostheses by rapid prototyping techniques.

    Science.gov (United States)

    Karatas, Meltem Ozdemir; Cifter, Ebru Demet; Ozenen, Didem Ozdemir; Balik, Ali; Tuncer, Erman Bulent

    2011-08-01

    Maxillofacial prostheses are usually fabricated on the models obtained following the impression procedures. Disadvantages of conventional impression techniques used in production of facial prosthesis are deformation of soft tissues caused by impression material and disturbance of the patient due to. Additionally production of prosthesis by conventional methods takes longer time. Recently, rapid prototyping techniques have been developed for extraoral prosthesis in order to reduce these disadvantages of conventional methods. Rapid prototyping technique has the potential to simplify the procedure and decrease the laboratory work required. It eliminates the need for measurement impression procedures and preparation of wax model to be performed by prosthodontists themselves In the near future this technology will become a standard for fabricating maxillofacial prostheses.

  5. [Surgical silicone prostheses in the treatment of biliary tract cancers: long prostheses or short prostheses? Results apropos of 500 cases].

    Science.gov (United States)

    Kron, B

    1992-10-01

    The interest of surgical prostheses in the palliative treatment of biliary tract cancer is well established, on the basis of their good tolerance, the more than 15 year follow up experience and the number of patients operated upon. After exeresis, they allow re-establishment of continuity, either by use of a prosthesis in Y when the right and let ducts can be dissected, or by using two prostheses, a multiperforated long prosthesis reimplanted in the duodenum and a short prosthesis reimplanted in the common bile duct without attaining the sphincter of Oddi. Of the 1000 cases treated, 500 were the object of a statistical analysis, 46 being operated upon by the author, in 60% of cases for biliary tract cancer, either primary or as an extension from the gallbladder. One-third of the patients had advanced lesions and a short survival of less than 3 months. Two-thirds a median survival of 9 months. In 10%, a radical exeresis was performed with survival of more than one year without recurrence of jaundice. Failure of treatment with persistence of jaundice was due to advanced disease for which surgery is unsatisfactory. Essential complications were premature bile leaks (5%) without serious consequences if sufficient drainage was maintained, since it stopped spontaneously, and angiocholitis (6%), the result of territory exclusion or reflux. Recurrence of jaundice was related to extension of the neoplasm to the secondary bile ducts, and to hepatic metastases. Obstruction of the prosthesis before two months was rare (6%) and was preceded by angiocholitis. In the absence of recurrence of the cancer the prosthesis can be replaced surgically without difficulty.

  6. What are estimated reimbursements for lower extremity prostheses capable of surgical and nonsurgical lengthening?

    Science.gov (United States)

    Henderson, Eric R; Pepper, Andrew M; Letson, G Douglas

    2012-04-01

    Growing prostheses accommodate skeletally immature patients with bone tumors undergoing limb-preserving surgery. Early devices required surgical procedures for lengthening; recent devices lengthen without surgery. Expenses for newer expandable devices that lengthen without surgery are more than for their predecessors but overall reimbursement amounts are not known. We sought to determine reimbursement amounts associated with lengthening of growing prostheses requiring surgical and nonsurgical lengthening. We retrospectively reviewed 17 patients with growing prostheses requiring surgical expansion and eight patients with prostheses capable of nonsurgical expansion. Insurance documents were reviewed to determine the reimbursement for implantation, lengthening, and complications. Growth data were obtained from the literature. Mean reimbursement amounts of surgical and nonsurgical lengthenings were $9950 and $272, respectively. Estimated reimbursements associated with implantation of a growing prosthesis varied depending on age, sex, and location. The largest difference was found for 4-year-old boys with distal femoral replacement where reimbursement for expansion to maturity for surgical and nonsurgical lengthening prostheses would be $379,000 and $208,000, respectively. For children requiring more than one surgical expansion, net reimbursements were lower when a noninvasive lengthening device was used. Annual per-prosthesis maintenance reimbursements to address complications for surgical and nonsurgical lengthening prostheses were $3386 and $1856, respectively. This study showed that reimbursements for lengthening of growing endoprostheses capable of nonsurgical expansion may be less expensive in younger patients, particularly male patients undergoing distal femur replacement, than endoprostheses requiring surgical lengthening. Longer outcomes studies are required to see if reimbursements for complications differ between devices. Level III, economic and decision

  7. The Use of Prostheses in Pelvic Reconstructive Surgery: Joy or Toy?

    Directory of Open Access Journals (Sweden)

    Ming-Ping Wu

    2008-06-01

    Full Text Available The high recurrence rate of pelvic organ prolapse (POP of up to 30% after pelvic reconstructive surgery makes a more refined surgery imperative, as well as the need for either biological or synthetic prostheses as adjuvant treatment. Patients with recurrence risks may benefit from the adjuvant treatment: (1 to substitute for the lack of supportive tissue; (2 to reinforce inadequate tissue; (3 to induce new supportive tissue; and (4 to consolidate and complement the insufficient surgical techniques. However, some debatable issues in use of the prosthetics remain. The use of prosthetics enables the simultaneous repair of all vaginal defects of POP and concomitant anti-incontinence surgery to be faster, easier and more precise. Nevertheless, great care should be devoted to the actual and theoretical short- and long-term risks, many of which have not been fully elucidated. Despite the lack of various ideal characteristics, the type I monofilament, macroporous polypropylene, has been suggested to have the lowest incidence of infection and erosion among the nonabsorbable prostheses. There is good evidence to support the use of nonabsorbable synthetic mesh for abdominal sacrocolpopexy, while the use of prostheses for repairing isolated anterior and posterior compartment defects remains controversial. There have been no long-term studies with sufficient patient numbers to prove whether synthetic or biological prostheses are superior during vaginal surgery. Tension-free vaginal mesh techniques with procedural kits are being adopted increasingly, despite the paucity of data. Although short-term follow-up studies have shown tension-free vaginal mesh to be a safe and effective technique to correct POP, anatomic and functional results of long-term follow-up studies, however, have not yet confirmed the effectiveness and safety. Mesh erosion remains a concern, with variable rates according to different materials and approaches. Newly developed prostheses offer

  8. Air-flow resistances of silicone rubber voice prostheses after formation of bacterial and fungal biofilms

    NARCIS (Netherlands)

    Elving, GJ; van der Mei, HC; Busscher, HJ; van Weissenbruch, R; Albers, FWJ

    Laryngectomized patients use silicone rubber voice prostheses to rehabilitate their voice. However, biofilm formation limits the lifetime of voice prostheses by causing leakage or an increased air-flow resistance and the prosthesis has to be replaced. To determine which bacterial or yeast strains,

  9. Study of effects of radiation on silicone prostheses

    International Nuclear Information System (INIS)

    Shedbalkar, A.R.; Devata, A.; Padanilam, T.

    1980-01-01

    Radiation effects on silicone gel and dose distribution of radiation through mammary prostheses were studied. Silicone gel behaves like tissue. Half value thickness for silicone gel and water are almost the same. Linear absorption coefficient for silicone gel and water are comparable

  10. Evaluation of taper joints with combined fatigue and crevice corrosion testing: Comparison to human explanted modular prostheses

    Energy Technology Data Exchange (ETDEWEB)

    Reclaru, L., E-mail: lucien.reclaru@pxgroup.com [PX Group S.A., Dep R and D Corrosion and Biocompatibility Group, Bd. des Eplatures 42, CH-2304 La Chaux-de-Fonds (Switzerland); Brooks, R.A. [Orthopaedic Research, Addenbrooke' s Hospital, University of Cambridge, Box 180 Hills Road, CB2 0QQ Cambridge (United Kingdom); Zuberbühler, M. [Smith and Nephew Orthopaedics AG, Schachenalle 29, 5001 Aarau (Switzerland); Eschler, P.-Y.; Constantin, F. [PX Group S.A., Dep R and D Corrosion and Biocompatibility Group, Bd. des Eplatures 42, CH-2304 La Chaux-de-Fonds (Switzerland); Tomoaia, G. [University of Medicine and Pharmacy Iuliu Hateganu of Cluj-Napoca, Dept. of Orthopaedics and Traumatology, Cluj-Napoca (Romania)

    2014-01-01

    The requirement for revision surgery of total joint replacements is increasing and modular joint replacement implants have been developed to provide adjustable prosthetic revision systems with improved intra-operative flexibility. An electrochemical study of the corrosion resistance of the interface between the distal and proximal modules of a modular prosthesis was performed in combination with a cyclic fatigue test. The complexity resides in the existence of interfaces between the distal part, the proximal part, and the dynamometric screw. A new technique for evaluating the resistance to cyclic dynamic corrosion with crevice stimulation was used and the method is presented. In addition, two components of the proximal module of explanted Ti6Al4V and Ti6Al7Nb prostheses were investigated by optical and electron microscopy. Our results reveal that: The electrolyte penetrates into the interface between the distal and proximal modules during cyclic dynamic fatigue tests, the distal module undergoes cracking and corrosion was generated at the interface between the two models; The comparison of the explanted proximal parts with the similar prostheses evaluated following cyclic dynamic crevice corrosion testing showed that there were significant similarities indicating that this method is suitable for evaluating materials used in the fabrication of modular prostheses. - Highlights: • Electrochemical crevice corrosion testing combined with fatigue test conducted on Ti6Al7Nb and Ti6Al4V modular prostheses • Cations released from integral prostheses • Comparison of human explanted modular prostheses with the similar prostheses evaluated in cyclic dynamic crevice corrosion.

  11. Evaluation of pneumatic cylinder actuators for hand prostheses

    NARCIS (Netherlands)

    Peerdeman, B.; Smit, Gerwin; Stramigioli, Stefano; Plettenburg, Dick; Misra, Sarthak

    2012-01-01

    DC motors are currently the preferred actuation method for externally powered hand prostheses. However, they are often heavy and large, which limits the number of actuators that can be integrated into the prosthesis. Alternative actuation methods are being researched, but have not yet found wide

  12. Interest of Flow Diversion Prostheses in the Management of Unruptured Intracranial Aneurysms

    Directory of Open Access Journals (Sweden)

    Xavier Armoiry

    2012-01-01

    Full Text Available Flow diversion prostheses represent a new endovascular approach aimed at treating patients with large wide-neck aneurysms. Our objective is to present this new technology, to review the clinical studies on efficacy, and to emphasize its current limits. Flow diversion prostheses consist of a cylinder made of a large number of braided microfilaments providing a large metallic surface when deployed and inducing a blood flow diversion outside the aneurysm. Two different brands are currently available. Clinical data supporting their efficacy are currently limited to six non comparative cohort studies that included between 18 and 107 patients. Procedural implantation was shown to be feasible in more than 90% and safe with a thirty-day mortality between 2.8 and 5.5%. Complete occlusion rates at twelve months varied between 85.7 and 100%. Even though promising, the current status of flow diversion prostheses needs further evaluation with randomized, prospective, clinical trials with comparison to conventional strategies including endovascular coiling or surgical clipping.

  13. Prostheses and orthoses in the collections of the Auschwitz-Birkenau State Museum.

    Science.gov (United States)

    Przeździak, Bogumił; Lutomirski, Adam; Kulczyk, Maria

    2011-01-01

    The authors described 424 orthopaedic appliances left by the prisoners of the Nazi Concentration Camp in Oświęcim. A collection of prostheses and orthoses, which is currently a part of the Auschwitz-Birkenau State Museum's exhibition, is extraordinary as it illustrates the fate of innocent, crippled people, who were incarcerated and murdered. Another point of value of the collection is its technical aspect, as it provides a clear picture of construction of prostheses and orthoses at the beginning of the 20th century.

  14. Aging of monolithic zirconia dental prostheses: Protocol for a 5-year prospective clinical study using ex vivo analyses

    OpenAIRE

    Koenig, Vinciane; Wulfman, Claudine P.; Derbanne, Mathieu A.; Dupont, Nathalie M.; Le Goff, Stéphane O.; Tang, Mie-Leng; Seidel, Laurence; Dewael, Thibaut Y.; Vanheusden, Alain J.; Mainjot, Amélie K.

    2016-01-01

    Background: Recent introduction of computer-aided design/computer-aided manufacturing (CAD/CAM) monolithic zirconia dental prostheses raises the issue of material low thermal degradation (LTD), a well-known problem with zirconia hip prostheses. This phenomenon could be accentuated by masticatory mechanical stress. Until now zirconia LTD process has only been studied in vitro. This work introduces an original protocol to evaluate LTD process of monolithic zirconia prostheses in the oral enviro...

  15. New total ossicular replacement prostheses with a resilient joint: experimental data from human temporal bones.

    Science.gov (United States)

    Arechvo, Irina; Bornitz, Matthias; Lasurashvili, Nikoloz; Zahnert, Thomas; Beleites, Thomas

    2012-01-01

    New flexible total ossicular prostheses with an integrated microjoint can compensate for large static displacements in the reconstructed ossicular chain. When properly designed, they can mimic the function of the joints of the intact chain and ensure good vibration transfer in both straight and bent conditions. Prosthesis dislocations and extrusions are frequently observed after middle ear surgery. They are mainly related to the altered distance between the coupling points because of large static eardrum displacements. The new prostheses consist of 2 titanium shafts, which are incorporated into a silicone body. The sound transfer function and stapes footplate displacement at static loads were evaluated in human temporal bones after ossicular reconstruction using prostheses with 2 different silicones with different hardness values. The stiffness and bending characteristics of the prostheses were investigated with a quasi-static load. The sound transfer properties of the middle ears with the prostheses inserted under uncompressed conditions were comparable with those of ears with intact ossicular chains. The implant with the soft silicone had improved acoustic transfer characteristics over the implant with the hard silicone in a compressed state. In the quasi-static experiments, the minimum medial footplate displacement was found with the same implant. The bending characteristics depended on the silicone stiffness and correlated closely with the point and angle of the load incidence. The titanium prostheses with a resilient joint that were investigated in this study had good sound transfer characteristics under optimal conditions as well as in a compressed state. As a result of joint bending, the implants compensate for the small changes in length of the ossicular chain that occur under varying middle ear pressure. The implants require a stable support at the stapes footplate to function properly.

  16. Natural History of Bone Response to Hydroxyapatite-Coated Hip Prostheses Implanted in Humans

    OpenAIRE

    Frayssinet, P.; Hardy, D.; Hanker, J. S.; Giammara, B. L.

    1995-01-01

    A series of 15 autopsied femurs containing hydroxyapatite- coated (HA-coated) prostheses was analysed histologically. Their implantation time ranged from 5 days up to 3 years. The coating thickness of some prostheses and the percentage of the coating in contact with bone at different levels were evaluated using an image analysis device. After the newly formed bone tissue had became mature, several bone morphotypes were identified at the coating contact. From the proximal to the distal part of...

  17. Visual prostheses: The enabling technology to give sight to the blind

    Directory of Open Access Journals (Sweden)

    Mohammad Hossein Maghami

    2014-01-01

    Full Text Available Millions of patients are either slowly losing their vision or are already blind due to retinal degenerative diseases such as retinitis pigmentosa (RP and age-related macular degeneration (AMD or because of accidents or injuries. Employment of artificial means to treat extreme vision impairment has come closer to reality during the past few decades. Currently, many research groups work towards effective solutions to restore a rudimentary sense of vision to the blind. Aside from the efforts being put on replacing damaged parts of the retina by engineered living tissues or microfabricated photoreceptor arrays, implantable electronic microsystems, referred to as visual prostheses, are also sought as promising solutions to restore vision. From a functional point of view, visual prostheses receive image information from the outside world and deliver them to the natural visual system, enabling the subject to receive a meaningful perception of the image. This paper provides an overview of technical design aspects and clinical test results of visual prostheses, highlights past and recent progress in realizing chronic high-resolution visual implants as well as some technical challenges confronted when trying to enhance the functional quality of such devices.

  18. Reduction of metal artifacts from hip prostheses on CT images of the pelvis: value of iterative reconstructions.

    Science.gov (United States)

    Morsbach, Fabian; Bickelhaupt, Sebastian; Wanner, Guido A; Krauss, Andreas; Schmidt, Bernhard; Alkadhi, Hatem

    2013-07-01

    To assess the value of iterative frequency split-normalized (IFS) metal artifact reduction (MAR) for computed tomography (CT) of hip prostheses. This study had institutional review board and local ethics committee approval. First, a hip phantom with steel and titanium prostheses that had inlays of water, fat, and contrast media in the pelvis was used to optimize the IFS algorithm. Second, 41 consecutive patients with hip prostheses who were undergoing CT were included. Data sets were reconstructed with filtered back projection, the IFS algorithm, and a linear interpolation MAR algorithm. Two blinded, independent readers evaluated axial, coronal, and sagittal CT reformations for overall image quality, image quality of pelvic organs, and assessment of pelvic abnormalities. CT attenuation and image noise were measured. Statistical analysis included the Friedman test, Wilcoxon signed-rank test, and Levene test. Ex vivo experiments demonstrated an optimized IFS algorithm by using a threshold of 2200 HU with four iterations for both steel and titanium prostheses. Measurements of CT attenuation of the inlays were significantly (P algorithm for CT image reconstruction significantly reduces metal artifacts from hip prostheses, improves the reliability of CT number measurements, and improves the confidence for depicting pelvic abnormalities.

  19. Magnetic resonance imaging of breast prostheses | Corr | SA ...

    African Journals Online (AJOL)

    Breast MR imaging is the most accurate imaging investigation to detect breast prosthesis rupture. Rupture is common in older prostheses (> 10 years post implantation) and is often asymptomatic. The radiological signs of rupture are due to collapse of the elastomer shell which is eneveloped by silicone gel and when the ...

  20. Radiological and scintigraphic evaluation of hip prostheses

    International Nuclear Information System (INIS)

    Bessler, W.; Schaub, W.

    1979-01-01

    The radiological findings following the introduction of hip prostheses are often equivocal. Additional bone scintigrams often provide important information for the evaluation of the prostheses. 1. An unstable hip prosthesis is characterised by abnormal uptake in bone, due to static and mechanical stress. 2. A positive scintigram does not necessarily indicate instability of the prosthesis. Increased uptake may also be due to inflammatory bone changes, healing, bone replacement, abnormal local stresses or soft tissue calcification. 3. In evaluating the scintigram one must take account not only of the intensity of isotope uptake, but also its distribution and exact localisation. 4. It is essential to compare the scintigram with the radiograph. Radiological features of possible instability become diagnostic if they correspond with appropriate increased radioactivity. If the latter is absent, the of instability remains doubtful. 5. In some cases early loosening of the stem of the prosthesis can be diagnosed while the radiograph is still negative. Increased radioactivity in the acetabulum is frequently seen in the presence of a stable acetabular prosthesis and must be interpreted with caution as a sign of loosening of the prosthesis. (orig.) [de

  1. Evaluation of osseous integration of PVD-silver-coated hip prostheses in a canine model.

    Science.gov (United States)

    Hauschild, Gregor; Hardes, Jendrik; Gosheger, Georg; Stoeppeler, Sandra; Ahrens, Helmut; Blaske, Franziska; Wehe, Christoph; Karst, Uwe; Höll, Steffen

    2015-01-01

    Infection associated with biomaterials used for orthopedic prostheses remains a serious complication in orthopedics, especially tumor surgery. Silver-coating of orthopedic (mega)prostheses proved its efficiency in reducing infections but has been limited to surface areas exposed to soft tissues due to concerns of silver inhibiting osseous integration of cementless stems. To close this gap in the bactericidal capacity of silver-coated orthopedic prostheses extension of the silver-coating on surface areas intended for osseous integration seems to be inevitable. Our study reports about a PVD- (physical-vapor-deposition-) silver-coated cementless stem in a canine model for the first time and showed osseous integration of a silver-coated titanium surface in vivo. Radiological, histological, and biomechanical analysis revealed a stable osseous integration of four of nine stems implanted. Silver trace elemental concentrations in serum did not exceed 1.82 parts per billion (ppb) and can be considered as nontoxic. Changes in liver and kidney functions associated with the silver-coating could be excluded by blood chemistry analysis. This was in accordance with very limited metal displacement from coated surfaces observed by laser ablation inductively coupled plasma-mass spectrometry (LA-ICP-MS) 12 months after implantation. In conclusion our results represent a step towards complete bactericidal silver-coating of orthopedic prostheses.

  2. Adhesion to silicone rubber of yeasts and bacteria isolated from voice prostheses : Influence of salivary conditioning films

    NARCIS (Netherlands)

    Busscher, HJ; GeertsemaDoornbusch, GI; vanderMei, HC

    Adhesion of yeasts and bacteria to silicone rubber is one of the first steps in the biodeterioration of silicone rubber voice prostheses. In this paper, adhesion of two streptococcal, staphylococcal, Candida albicans and Candida tropicalis strains, isolated from explanted voice prostheses was

  3. Effect of treatment with fixed and removable dental prostheses. An oral health-related quality of life study

    DEFF Research Database (Denmark)

    Øzhayat, Esben Boeskov; Gotfredsen, Klaus

    2012-01-01

    The aim of the study was to evaluate patient-reported effects of treatment with fixed dental prostheses (FDP) and removable dental prostheses (RDP) and relate the change in Oral Health Related Quality of Life (OHRQoL) to the type of treatment and objective dental variables of aesthetics and masti......The aim of the study was to evaluate patient-reported effects of treatment with fixed dental prostheses (FDP) and removable dental prostheses (RDP) and relate the change in Oral Health Related Quality of Life (OHRQoL) to the type of treatment and objective dental variables of aesthetics...... were obtained. The participants completed the Oral Health Impact Profile 49 (OHIP-49) before and after treatment. A control group with no need for dental treatment also completed the OHIP-49. All participants had a significant improvement in OHRQoL. The improvement was higher for the RDP group than...

  4. Monte Carlo dose calculations for phantoms with hip prostheses

    International Nuclear Information System (INIS)

    Bazalova, M; Verhaegen, F; Coolens, C; Childs, P; Cury, F; Beaulieu, L

    2008-01-01

    Computed tomography (CT) images of patients with hip prostheses are severely degraded by metal streaking artefacts. The low image quality makes organ contouring more difficult and can result in large dose calculation errors when Monte Carlo (MC) techniques are used. In this work, the extent of streaking artefacts produced by three common hip prosthesis materials (Ti-alloy, stainless steel, and Co-Cr-Mo alloy) was studied. The prostheses were tested in a hypothetical prostate treatment with five 18 MV photon beams. The dose distributions for unilateral and bilateral prosthesis phantoms were calculated with the EGSnrc/DOSXYZnrc MC code. This was done in three phantom geometries: in the exact geometry, in the original CT geometry, and in an artefact-corrected geometry. The artefact-corrected geometry was created using a modified filtered back-projection correction technique. It was found that unilateral prosthesis phantoms do not show large dose calculation errors, as long as the beams miss the artefact-affected volume. This is possible to achieve in the case of unilateral prosthesis phantoms (except for the Co-Cr-Mo prosthesis which gives a 3% error) but not in the case of bilateral prosthesis phantoms. The largest dose discrepancies were obtained for the bilateral Co-Cr-Mo hip prosthesis phantom, up to 11% in some voxels within the prostate. The artefact correction algorithm worked well for all phantoms and resulted in dose calculation errors below 2%. In conclusion, a MC treatment plan should include an artefact correction algorithm when treating patients with hip prostheses

  5. SPONGE ROBOTIC HAND DESIGN FOR PROSTHESES

    OpenAIRE

    Mine Seçkin

    2016-01-01

    In this study robotic hands and fingers’ materials are investigated from past to present and a sponge robotic hand is designed for biomedical applications. Emergence and necessity of soft robotic technology are explained and description of soft robot is made. Because of the importance of hand in a person’s body, researchers have dealt with robotic hand prostheses for many centuries and developed many hand types. To mimic the best for the human limbs, softness of the hand is one of the importa...

  6. Antibiotic cements in articular prostheses: current orthopaedic concepts.

    Science.gov (United States)

    Langlais, F; Belot, N; Ropars, M; Thomazeau, H; Lambotte, J C; Cathelineau, G

    2006-08-01

    The possibilities and limits of antibiotic cements (ACs) have been assessed by many researchers. ACs are now approved by many drug agencies, including the US Food and Drug Administration (approval in 2003), with widespread use in prophylaxis and curative treatments. Laboratory experiments have achieved satisfactory antibiotic delivery without impairing the mechanical properties of ACs. Implantation in large animals (e.g. sheep) showed an antibiotic concentration in the bone cortex four times the minimal inhibitory concentration (MIC) 6 months after implantation. Human pharmacokinetics during total hip replacement (THR) show antibiotic concentrations 20 times the MIC in drainage fluids. No toxic concentrations have been detected in blood or urine, and no allergies, toxic effects, mechanical failures or selection of resistant microorganisms have been observed. Antibioprophylaxis has been assessed in prospective studies in over 1600 cases. In data from the Scandinavian arthroplasty registers, with an exhaustive follow-up of more than 240000 THRs, infection rate was reduced by ca. 50% (0.9% compared with 1.9%). In prostheses with severe infection, use of AC increases the infection control rate from 86% to 93% when using two-stage prosthetic exchanges. In moderate infection, a similar infection control rate (86%) was achieved either by two-stage exchange without local antibiotic or by one-stage exchange with AC; however, one-stage exchange achieved better functional results at lower cost and with reduced pain and hospital stay. Therefore, AC prophylaxis is widely used in countries with prostheses registers (Northern Europe), and use of ACs as treatment for infected prostheses is often considered as the gold standard in the EU and North America. However, AC is only an adjuvant treatment, and excision of infected and devascularized tissues as well as systemic antibiotic treatment managed by a multidisciplinary team remain the main factors of infection control.

  7. Critiquing the Computer-Aided Design of Dental Prostheses.

    Science.gov (United States)

    Fitzpatrick, F. J.; And Others

    This paper describes RaPiD, a computer-aided assistant for the design of dental prostheses called removable partial dentures. The user manipulates icons directly to indicate the desired design solution to a given clinical situation. A developing design is represented as a logic database of components in a design; expert rules are applied as…

  8. Polyrethene nasolacrimal prostheses. Assessment of the complications using computed tomography

    International Nuclear Information System (INIS)

    Pino, I. T.; Paul, L.; Duran, M. A.; Grande, C.

    1999-01-01

    To assess the outcome of treatment of epiphora secondary to nasolacrimal duct obstruction by placement of a polyurethane prosthesis. We placed 20 polyurethane prostheses (song's prostheses) in 19 patients with nasolacrimal duct obstruction who presented idiopathic grade III-IV epiphora. All the patients underwent CT with follow-up studies 10 days, one month and three months after prosthesis placement. Epiphora resolved completely in 13 cases and partially in four. In two cases, the prosthesis was poorly positioned; one of them was replaced and the other functions to date. There were three cases of obstruction. We observed limited epistaxis in 7 patients and headache in one. The treatment of epiphora by polyurethane prosthesis placement is a simple procedure that is well tolerated by patients and has a high success rate. (Author) 14 refs

  9. The improvement of polyethylene prostheses through radiation crosslinking

    International Nuclear Information System (INIS)

    Du Plessis, T.A.; Grobbelaar, C.J.; Marais, F.

    1977-01-01

    During the past decade, remarkable progress has been made in the utilization of high-density polyethylene (HDPE) as a material for the manufacture of prostheses used in orthopaedic operations. This polymer contributes largely to the success of total hip replacement. In the case of total knee replacement it was considered imperative that a more hard-wearing polymer should be developed if at all possible, because not only are the cold-flow characteristics of ordinary high-density polyethylene at high pressures a limiting factor, but particle formation from friction can furthermore lead to physiological side-effects which adversely affect the efficacy of joints made from this material, especially so in the case of knee-joints. Bearing in mind the excellent improvements to be obtained through the radiation crosslinking of polyethylene film, the radiation crosslinking of high-density polyethylene prostheses seemed to be a logical avenue to investigate. Experimental details are presented. Gamma radiation was used. Impact strength and tensile strength measurements were made on specimens irradiated over a dose range of 0 to 80 Mrad. The results are discussed. (U.K.)

  10. Temperature variations in sintering ovens for metal ceramic dental prostheses: non-destructive assessment using OCT

    Science.gov (United States)

    Sinescu, C.; Bradu, A.; Duma, V.-F.; Topala, F. I.; Negrutiu, M. L.; Podoleanu, A. G.

    2018-02-01

    We present a recent investigation regarding the use of optical coherence tomography (OCT) in the monitoring of the calibration loss of sintering ovens for the manufacturing of metal ceramic dental prostheses. Differences in the temperatures of such ovens with regard to their specifications lead to stress and even cracks in the prostheses material, therefore to the failure of the dental treatment. Evaluation methods of the ovens calibration consist nowadays of firing supplemental samples; this is subjective, expensive, and time consuming. Using an in-house developed swept source (SS) OCT system, we have demonstrated that a quantitative assessment of the internal structure of the prostheses, therefore of the temperature settings of the ovens can be made. Using en-face OCT images acquired at similar depths inside the samples, the differences in reflectivity allow for the evaluation of the differences in granulation (i.e., in number and size of ceramic grains) of the prostheses material. Fifty samples, divided in five groups, each sintered at different temperatures (lower, higher, or equal to the prescribed one) have been analyzed. The consequences of the temperature variations with regard to the one prescribed were determined. Rules-of-thumb were extracted to monitor objectively, using only OCT images of currently manufactured samples, the settings of the oven. The method proposed allows for avoiding producing prostheses with defects. While such rules-of-thumb achieve a qualitative assessment, an insight in our on-going work on the quantitative assessment of such losses of calibration on dental ovens using OCT is also made.

  11. Objective clinical assessment of change in swallowing ability of maxillectomy patients when wearing obturator prostheses.

    Science.gov (United States)

    Matsuyama, Miwa; Tsukiyama, Yoshihiro; Koyano, Kiyoshi

    2005-01-01

    Evaluation of treatment outcome is important in maxillofacial rehabilitation. Although eating is one of the oral functions that most strongly influences patients' quality of life, only a few reports exist on the objective assessment of swallowing for maxillectomy patients. The purpose of this study was to identify changes in the swallowing ability of maxillectomy patients when wearing obturator prostheses through the use of an objective clinical assessment. The swallowing ability of 38 postmaxillectomy patients consecutively treated with obturator prostheses was objectively evaluated with the "water-drinking test" that was developed for the assessment of dysphagia patients after cerebrovascular disease. In this test, the subjects were instructed to drink 30 mL of water in one swallow. The profile was evaluated with the combination of the time required for drinking the water and the incidence of cough reflex. Statistical analysis was performed using the Wilcoxon signed-rank test, the paired t test, and the Chi-square test with StatView 5.0 for the Macintosh. Performance improved significantly when the patients wore prostheses (P = .0026, Wilcoxon signed-rank test). The mean drinking times without and with prostheses were 8.2 +/- 6.3 s and 5.0 +/- 3.5 s, respectively. Drinking time was shortened significantly when the prosthesis was worn (P = .0002, paired t test). The assessment of behavior and episodes revealed that the swallowing ability of the maxillectomy patients was significantly improved when a prosthesis was worn (P = .0002, Chi-square test). The swallowing ability of maxillectomy patients was quantitatively and qualitatively improved with obturator prostheses.

  12. Accelerated treatment protocols: full arch treatment with interim and definitive prostheses.

    Science.gov (United States)

    Drago, Carl

    2012-01-01

    With the advent of titanium, root form implants and osseointegration, dental treatment has undergone a metamorphosis in recent years. These new techniques enable dentists to provide anchorage for various kinds of prostheses that improve masticatory function, esthetics, and comfort for patients. Implant treatment protocols have been improved relative to implant macro- and micro-geometries, surgical and prosthetic components, and treatment times. Over the past 20 years, immediate occlusal function (also known as loading) has been established as a predictable treatment modality, provided certain specific criteria are met. In many cases, edentulous patients, crippled by the loss of their teeth, can undergo outpatient surgical and prosthetic procedures and return to a masticatory function that is near normal--sometimes after only one day of surgical and prosthetic treatment. This treatment option is also available for patients with advanced, generalized periodontal disease. Computer-assisted design/Computer-assisted manufacturing (CAD/CAM) has transformed how dental prostheses are made, offering improved accuracy, longevity, and biocompatibility; along with reduced labor costs and fewer complications than casting technologies. This article reviews the principles associated with immediate occlusal loading and illustrates one specific accelerated prosthodontic treatment protocol used to treat edentulous and partially edentulous patients with interim and definitive prostheses.

  13. PIXE characterization of tissues surrounding metallic prostheses coated with biological glasses

    International Nuclear Information System (INIS)

    Barbotteau, Y.; Irigaray, J.L.; Moretto, Ph.

    2004-01-01

    Biological glasses can be used as coatings for metallic prostheses in order to prevent corrosion. According to their composition, these glasses have different properties. We studied, in vivo, two glasses referred to as BVA and BVH. They are used as coatings of Ti6Al4V metallic implant. BVA glass disappears after 3 months of implantation and is replaced by bone. Prostheses initially coated by this glass have a larger osseous contact perimeter compared to the uncoated prostheses. This ensures a better anchoring of the implant and limits the micro-motions which cause wear debris. BVH glass keeps a constant composition during implantation and it is used like a layer which isolates metal implant from biological environment. In order to characterize the bony environment surrounding implants, we have used PIXE and RBS methods. This paper shows results of the behavior of bony tissue under micro-beam, the quality tests of new bone which replaces the BVA glass coating and the evaluation of corrosion effects. Titanium release in bony tissues begins when the metal surface of the prosthesis is exposed to biological fluids. After a few months of implantation, the titanium contamination is stabilized and remains localized within the first tens of micrometers of surrounding bone

  14. Impact of implant-supported prostheses on nutritional status and oral health perception in edentulous patients.

    Science.gov (United States)

    El Osta, Nada; El Osta, Lana; Moukaddem, Farah; Papazian, Tatiana; Saad, Robert; Hennequin, Martine; Rabbaa Khabbaz, Lydia

    2017-04-01

    Improvement of nutritional status and perception of oral health are supposed to be different with complete conventional denture or implant-supported fixed or removable prostheses. Since no study has been conducted in Lebanon, the aim of our study was to assess the nutritional status and oral heath related quality of life (OHRQoL) in totally edentulous patients after treatment with complete denture or implant supported-prostheses. This was an observational clinical prospective study. A convenient sample of Lebanese people aged 60 years or more was selected between September 2013 and July 2015 from the Departments of removable and fixed prosthesis at Saint-Joseph University of Beirut. The treatment options included complete denture, implant-supported complete denture and implant-supported fixed prostheses. Nutritional status and OHRQoL were assessed with the Mini-Nutritional Assessment Index (MNA) and the Geriatric Oral Health Assessment Index (GOHAI) respectively at Baseline (first visit before treatment), 2-3 weeks after treatment (t1), 3 months (t2) and 6 months (t3) after treatment. Fifty-one participants (mean age: 69.39 ± 7.164 years) were included. The results have shown an improvement over time in nutritional status and OHRQoL for all treatment groups. However, 2-3 weeks after treatment the number of participants at risk of malnutrition was higher with complete removable denture, intermediate with implant-supported complete denture and lower with implant-supported fixed prostheses (p-value = 0.049). Moreover, the mean GOHAI score was significantly lower over time with complete removable denture compared to implant-supported prostheses (p-value nutritional status for implant supported-prostheses compared to conventional removable dentures. Therefore, it is fundamental that dentists communicate with their patients about implant treatment to understand their expectations, to explain the outcomes and achieve the desired clinical result. Copyright © 2017

  15. Novel strategies to improve the patency of vascular prostheses

    NARCIS (Netherlands)

    Heyligers, J.M.M.

    2006-01-01

    Two novel strategies to improve the patency of vascular prostheses are described in this thesis. To improve the outcome of synthetic vascular bypass surgery, cell seeding is a promising concept that has extensively been investigated and is still evolving. To improve the short term effects due to

  16. [Endo-exo prostheses : Osseointegrated percutaneously channeled implants for rehabilitation after limb amputation].

    Science.gov (United States)

    Aschoff, H-H; Juhnke, D-L

    2016-05-01

    In 1999 the first endo-exo femoral prosthesis (EEFP) was implanted in Germany in a patient who had suffered a traumatic above-knee amputation. This procedure involves a skeletally anchored exoprosthetic device that is inserted into the residual femur. The distal part of the implant protrudes transcutaneously and allows attachment to a prosthetic limb which provides direct force transmission to the external prosthetic components. The technique originated from dental implantology and helps to avoid possible problems resulting from treatment of amputated limbs using socket prostheses. In the meantime, durability times of over 10 years have now helped to invalidate the initially well-founded reservations held against the procedure. What advantages can be achieved by osseointegrated and percutaneously channeled prostheses and which problems had to be overcome for treatment. Critical evaluation of data from patients operated on in Lübeck, Germany from January 2003 to December 2014. With osseointegrated and percutaneously channeled prostheses permanent durability times can be achieved. Infection-associated soft tissue problems at the site of skin protrusion (stoma) can be successfully prevented. The creation of this so-called stoma means acceptance of a possible bacterial portal of entry into the body. Patient satisfaction has so far been high, postoperative rehabilitation is simplified and the technique could possibly lower the costs of medical treatment. Endo-exo prostheses have proved to be successful for more than 15 years. A critical appraisal of the indications as well as a close cooperation between the surgeon, orthopedic technician and the associated rehabilitation facilities with the patient are the basis for the long-term success of this relatively new treatment approach.

  17. Development of friction and wear full-scale testing for TKR prostheses with reliable low cost apparatus

    Science.gov (United States)

    Suwandi, Agri; Soemardi, Tresna P.; Kiswanto, Gandjar; Kusumaningsih, Widjajalaksmi; I. Gusti Agung I. G., W.

    2018-02-01

    Prostheses products must undergo simulation and physical testing, before clinical testing. Finite element method is a preliminary simulation for in vivo test. The method visualizes the magnitude of the compressive force and the critical location of the Total Knee Replacement (TKR) prostheses design. In vitro testing is classified as physical testing for prostheses product. The test is conducted to evaluate the potential failure of the product and the characteristics of the prostheses TKR material. Friction and wear testing are part of the in vivo test. Motion of knee joints, which results in the phenomena of extension and deflection in the femoral and tibia insert, is represented by friction and wear testing. Friction and wear tests aim to obtain an approximate lifetime in normal and extreme load patterns as characterized by the shape of the friction surface area. The lifetime estimation requires friction and wear full-scale testing equipments for TKR prostheses products. These are necessary in obtaining initial data on potential product failures and characterizing of the material based on the ASTM F2724-08 standards. Based on the testing result and statistical analysis data, the average wear rate value per year is 2.19 × 10-3 mg/MC, with a 10 % safety limit of volume and 14,400 cycles times, for 15 hours moving nonstop then the prediction of wear life of the component tibia insert is ± 10 years.

  18. EFFICIENCY OF PROSTHETIC TREATMENT WITH POST RESECTION PROSTHESES WITH SOLID SUBSTITUTE PART

    Directory of Open Access Journals (Sweden)

    Ivan Gerdzhikov

    2016-08-01

    Full Text Available Aim: The aim of this study is to track the effectiveness of prosthetic treatment with post resection dentures with solid substitute part and their role in the restoration of damaged functions. Materials and methods: The study included 14 patients (9 men and 5 women with different size and location of defects in the upper jaw treated in the period 2010-2016 with post resection prostheses with a solid substitute part. The impressions were taken with irreversible hydrocolloid impression material. The prostheses were completed by heat-curing acrylic with low quantity residual monomer. The effectiveness of prosthetics was evaluated by the method of Mihaylov for both oral-nasal examination of the pressure with the device "Oronasopneumotest." For objectifying and assess the occlusal-articulation ratios was held computerized occlusal analysis with the system T-SCAN 8. Results: The results showed successful obturation and sealing of defects in all patients. It was found satisfactory recovery of the speaking function and normalization of occlusal-articulation ratios. Conclusion: The prosthetic treatment with post resection prostheses with a solid substitute part allows successful recovery of the lost speech and chewing functions, helping to restore self esteem and social rehabilitation of patients.

  19. External breast prostheses. A survey of their use by women after mastectomy.

    Science.gov (United States)

    Tanner, R; Abraham, S F; Llewellyn-Jones, D

    1983-03-19

    Women who have had a mastectomy for breast cancer have to cope with two major problems: first, that they have cancer, and second, that they have lost their physical appearance. The provision of an appropriate prosthesis can reduce the sense of disfigurement. If women were to obtain the full psychological benefit of wearing a breast prosthesis, they need to be informed about the available breast forms, have an opportunity to choose between them, and to be satisfied with their choice. In this study of 49 women, only 44% had had the opportunity to choose a prosthesis, 28% were dissatisfied with their prostheses, and 17% were still using temporary prostheses.

  20. Dental prostheses mimic the natural enamel behavior under functional loading: A review article

    Directory of Open Access Journals (Sweden)

    Ahmed A. Madfa

    2016-02-01

    Full Text Available Alumina- and zirconia-based ceramic dental restorations are designed to repair functionality as well as esthetics of the failed teeth. However, these materials exhibited several performance deficiencies such as fracture, poor esthetic properties of ceramic cores (particularly zirconia cores, and difficulty in accomplishing a strong ceramic–resin-based cement bond. Therefore, improving the mechanical properties of these ceramic materials is of great interest in a wide range of disciplines. Consequently, spatial gradients in surface composition and structure can improve the mechanical integrity of ceramic dental restorations. Thus, this article reviews the current status of the functionally graded dental prostheses inspired by the dentino-enamel junction (DEJ structures and the linear gradation in Young's modulus of the DEJ, as a new material design approach, to improve the performance compared to traditional dental prostheses. This is a remarkable example of nature's ability to engineer functionally graded dental prostheses. The current article opens a new avenue for recent researches aimed at the further development of new ceramic dental restorations for improving their clinical durability.

  1. Use of digital impression systems with intraoral scanners for fabricating restorations and fixed dental prostheses.

    Science.gov (United States)

    Takeuchi, Yoshimasa; Koizumi, Hiroyasu; Furuchi, Mika; Sato, Yohei; Ohkubo, Chikahiro; Matsumura, Hideo

    2018-01-01

    Accurate impressions are essential in fabri-cating dental restorations and fixed dental prostheses. During the last decade, digital impression systems have improved substantially. This review discusses the accuracy of digital impression systems for fabrication of dental restorations and fixed dental prostheses. A literature search in PubMed was performed for the period from July 2010 through June 2017. The search keywords were Cerec, digital impression, direct digitalization, indirect digitalization, and intraoral scanner. Only relevant studies are summarized and discussed in this review. In general, the latest systems have considerably reduced the time required for impression making, and the accuracy and marginal fit of digital impression systems have recently improved. Restorations and fixed dental prostheses fabricated with currently available digital impression systems and intraoral scanners exhibit clinically acceptable ranges of marginal gap in both direct and indirect procedures.

  2. Sport prostheses and prosthetic adaptations for the upper and lower limb amputees: an overview of peer reviewed literature.

    Science.gov (United States)

    Bragaru, Mihai; Dekker, Rienk; Geertzen, Jan H B

    2012-09-01

    Sport prostheses are used by both upper- and lower-limb amputees while participating in sports and other physical activities. Although the number of these devices has increased over the past decade, no overview of the peer reviewed literature describing them has been published previously. Such an overview will allow specialists to choose appropriate prostheses based on available scientific evidence rather than on personal experience or preference. To provide an overview of the sport prostheses as they are described by the papers published in peer reviewed literature. Literature review. Four electronic databases were searched using free text and Medical Subject Headings (MESH) terms. Papers were included if they concerned a prosthesis or a prosthetic adaptation used in sports. Papers were excluded if they did not originate from peer reviewed sources, if they concerned prostheses for body parts other than the upper or lower limbs, if they concerned amputations distal to the wrist or ankle, or if they were written in a language other than English. Twenty-four papers were included in this study. The vast majority contained descriptive data and consisted of expert opinions and technical notes. Data concerning the energy efficiency, technical characteristics and special mechanical properties of prostheses or prosthetic adaptations for sports, other than running, are scarce.

  3. Investigation of the dosimetric accuracy of the isocenter shifting method in prostate cancer patients with and without hip prostheses

    International Nuclear Information System (INIS)

    Hwang, Andrew B.; Kinsey, Erica; Xia Ping

    2009-01-01

    Purpose: The use of image guided radiation therapy (IGRT) enables compensation for prostate movement by shifting the treatment isocenter to track the prostate on a daily basis. Although shifting the isocenter can alter the source to skin distances (SSDs) and the effective depth of the target volume, it is commonly assumed that these changes have a negligible dosimetric effect, and therefore, the number of monitor units delivered is usually not adjusted. However, it is unknown whether or not this assumption is valid for patient with hip prostheses, which frequently contain high density materials. Methods: The authors conducted a retrospective study to investigate dosimetric effect of the isocenter shifting method for prostate patients with and without hip prostheses. For each patient, copies of the prostate volume were shifted by up to 1.5 cm from the original position to simulate prostate movement in 0.5 cm increments. Subsequently, 12 plans were created for each patient by creating a copy of the original plan for each prostate position with the isocenter shifted to track the position of the shifted prostate. The dose to the prostate was then recalculated for each plan. For patients with hip prostheses, plans were created both with and without lateral beam angles entering through the prostheses. Results: Without isocenter shifting to compensate for prostate motion of 1.5 cm, the dose to the 95% of the prostate (D-95%) changed by an average of 30% and by up to 64%. This was reduced to less than 3% with the isocenter shifting method. It was found that for patients with hip prostheses, this technique worked best for treatment plans that avoided beam angles passing through the prostheses. Conclusions: The results demonstrated that the isocenter shifting method can accurately deliver dose to the prostate even in patients with hip prostheses.

  4. Optimization of tomotherapy treatment planning for patients with bilateral hip prostheses.

    Science.gov (United States)

    Chapman, David; Smith, Shaun; Barnett, Rob; Bauman, Glenn; Yartsev, Slav

    2014-02-04

    To determine the effect of different imaging options and the most efficient imaging strategy for treatment planning of patients with hip prostheses. The planning kilovoltage CT (kVCT) and daily megavoltage CT (MVCT) studies for three prostate cancer patients with bilateral hip prostheses were used for creating hybrid kVCT/MVCT image sets. Treatment plans were created for kVCT images alone, hybrid kVCT/MVCT images, and MVCT images alone using the same dose prescription and planning parameters. The resulting dose volume histograms were compared. The orthopedic metal artifact reduction (O-MAR) reconstruction tool for kVCT images and different MVCT options were investigated with a water tank fit with double hip prostheses. Treatment plans were created for all imaging options and calculated dose was compared with the one measured by a pin-point ion chamber. On average for three patients, the D35% for the bladder was 8% higher in plans based on MVCT images and 7% higher in plans based on hybrid images, compared to the plans based on kVCT images alone. Likewise, the D35% for the rectum was 3% higher than the kVCT based plan for both hybrid and MVCT plans. The average difference in planned D99% in the PTV compared to kVCT plans was 0.9% and 0.1% for MVCT and hybrid plans, respectively. For the water tank with hip prostheses phantom, the kVCT plan with O-MAR correction applied showed better agreement between the measured and calculated dose than the original image set, with a difference of -1.9% compared to 3.3%. The measured doses for the MVCT plans were lower than the calculated dose due to image size limitations. The best agreement was for the kVCT/MVCT hybrid plans with the difference between calculated and measured dose around 1%. MVCT image provides better visualization of patient anatomy and hybrid kVCT/MVCT study enables more accurate calculations using updated MVCT relative electron density calibration.

  5. Optimization of tomotherapy treatment planning for patients with bilateral hip prostheses

    International Nuclear Information System (INIS)

    Chapman, David; Smith, Shaun; Barnett, Rob; Bauman, Glenn; Yartsev, Slav

    2014-01-01

    To determine the effect of different imaging options and the most efficient imaging strategy for treatment planning of patients with hip prostheses. The planning kilovoltage CT (kVCT) and daily megavoltage CT (MVCT) studies for three prostate cancer patients with bilateral hip prostheses were used for creating hybrid kVCT/MVCT image sets. Treatment plans were created for kVCT images alone, hybrid kVCT/MVCT images, and MVCT images alone using the same dose prescription and planning parameters. The resulting dose volume histograms were compared. The orthopedic metal artifact reduction (O-MAR) reconstruction tool for kVCT images and different MVCT options were investigated with a water tank fit with double hip prostheses. Treatment plans were created for all imaging options and calculated dose was compared with the one measured by a pin-point ion chamber. On average for three patients, the D 35% for the bladder was 8% higher in plans based on MVCT images and 7% higher in plans based on hybrid images, compared to the plans based on kVCT images alone. Likewise, the D 35% for the rectum was 3% higher than the kVCT based plan for both hybrid and MVCT plans. The average difference in planned D99% in the PTV compared to kVCT plans was 0.9% and 0.1% for MVCT and hybrid plans, respectively. For the water tank with hip prostheses phantom, the kVCT plan with O-MAR correction applied showed better agreement between the measured and calculated dose than the original image set, with a difference of -1.9% compared to 3.3%. The measured doses for the MVCT plans were lower than the calculated dose due to image size limitations. The best agreement was for the kVCT/MVCT hybrid plans with the difference between calculated and measured dose around 1%. MVCT image provides better visualization of patient anatomy and hybrid kVCT/MVCT study enables more accurate calculations using updated MVCT relative electron density calibration

  6. Indium-111 chloride imaging in the detection of infected prostheses

    International Nuclear Information System (INIS)

    Sayle, B.A.; Fawcett, H.D.; Wilkey, D.J.; Cierny, G. III; Mader, J.T.

    1985-01-01

    Thirty-three patients with painful joint prostheses and a suspicion of infection were imaged with [ 111 In]chloride. A final diagnosis was established by culture in 19. Of these, 12 were categorized as true positives and three as true negatives. There were two false-positive studies, occurring in patients with knee prostheses. In both, the culture was obtained by aspiration. The sensitivity was 86%, specificity 60%, and accuracy 79%. Seventeen of the proven cases had bone imaging prior to [ 111 In]chloride imaging. All 17 static images were positive and were not helpful in differentiating loosening from infection. Using increased uptake on the blood-pool image as a criteria for infection, the sensitivity was 89%, but the specificity was 0. Adding flow studies made little difference in interpreting the blood-pool images. This study shows that [ 111 In]chloride imaging is more accurate in evaluating infection in prosthesis than bone imaging

  7. Microbial colonization of silicone voice prostheses used in laryngectomized patients

    NARCIS (Netherlands)

    Eerenstein, S. E.; Grolman, W.; Schouwenburg, P. F.

    1999-01-01

    The aim of this study was to identify the microbial colonization of dysfunctioning voice prostheses in laryngectomized patients and determine the influence of patient radiation therapy on prosthesis life span. In a 40-month period, 257 outpatient voice prosthesis replacements were carried out in a

  8. High Cable Forces Deteriorate Pinch Force Control in Voluntary-Closing Body-Powered Prostheses.

    Directory of Open Access Journals (Sweden)

    Mona Hichert

    Full Text Available It is generally asserted that reliable and intuitive control of upper-limb prostheses requires adequate feedback of prosthetic finger positions and pinch forces applied to objects. Body-powered prostheses (BPPs provide the user with direct proprioceptive feedback. Currently available BPPs often require high cable operation forces, which complicates control of the forces at the terminal device. The aim of this study is to quantify the influence of high cable forces on object manipulation with voluntary-closing prostheses.Able-bodied male subjects were fitted with a bypass-prosthesis with low and high cable force settings for the prehensor. Subjects were requested to grasp and transfer a collapsible object as fast as they could without dropping or breaking it. The object had a low and a high breaking force setting.Subjects conducted significantly more successful manipulations with the low cable force setting, both for the low (33% more and high (50% object's breaking force. The time to complete the task was not different between settings during successful manipulation trials.High cable forces lead to reduced pinch force control during object manipulation. This implies that low cable operation forces should be a key design requirement for voluntary-closing BPPs.

  9. Dose attenuation effect of hip prostheses in a 9-MV photon beam. Commercial treatment planning system versus Monte Carlo calculations

    International Nuclear Information System (INIS)

    Mesbahi, A.; Nejad, F.S.

    2007-01-01

    The purpose of this study was to investigate the dosimetric effect of various hip prostheses on pelvis lateral fields treated by a 9-MV photon beam using Monte Carlo (MC) and effective path-length (EPL) methods. The head of the Neptun 10 pc linac was simulated using the MCNP4C MC code. The accuracy of the MC model was evaluated using measured dosimetric features including depth dose values and dose profiles in a water phantom. The Alfard treatment planning system (TPS) was used for EPL calculations. A virtual water phantom with dimensions of 30 x 30 x 30 cm 3 and a cube with dimensions of 4 x 4 x 4 cm 3 made of various metals centered in 12 cm depth was used for MC and EPL calculations. Various materials including titanium, Co-Cr-Mo, and steel alloys were used as hip prostheses. Our results showed significant attenuation in absorbed dose for points after and inside the prostheses. Attenuations of 32%, 54% and 55% were seen for titanium, Co-Cr-Mo, and steel alloys, respectively, at a distance of 5 cm from the prosthesis. Considerable dose increase (up to 18%) was found at the water-prosthesis interface due to back-scattered electrons using the MC method. The results of EPL calculations for the titanium implant were comparable to the MC calculations. This method, however, was not able to predict the interface effect or calculate accurately the absorbed dose in the presence of the Co-Cr-Mo and steel prostheses. The dose perturbation effect of hip prostheses is significant and cannot be predicted accurately by the EPL method for Co-Cr-Mo or steel prostheses. The use of MC-based TPS is recommended for treatments requiring fields passing through hip prostheses. (author)

  10. Restoring natural sensory feedback in real-time bidirectional hand prostheses

    DEFF Research Database (Denmark)

    Raspopovic, Stanisa; Capogrosso, Marco; Petrini, Francesco Maria

    2014-01-01

    Hand loss is a highly disabling event that markedly affects the quality of life. To achieve a close to natural replacement for the lost hand, the user should be provided with the rich sensations that we naturally perceive when grasping or manipulating an object. Ideal bidirectional hand prosthese...

  11. Comparison of fixed implant-supported prostheses, removable implant-supported prostheses, and complete dentures: patient satisfaction and oral health-related quality of life.

    Science.gov (United States)

    Oh, Sung-Hee; Kim, Younhee; Park, Joo-Yeon; Jung, Yea Ji; Kim, Seong-Kyun; Park, Sun-Young

    2016-02-01

    The purpose of this study was to compare patient satisfaction and oral health-related quality of life (OHRQoL) among fully edentulous patients treated with either fixed implant-supported prostheses (FP), removable implant-supported prostheses (RP), or complete dentures (CD). Eighty-six patients - 29 FP, 27 RP, and 30 CD patients - participated in this study. The survey was conducted using face-to-face interviews with a questionnaire that included a patient satisfaction scale and Oral Health Impact Profile (OHIP-14). We measured patient satisfaction after prosthetic treatments and OHRQoL before and after the treatments. After prosthetic treatments, OHRQoL increased in all three groups (P patient satisfaction and OHRQoL, and both groups showed greater improvement compared with the CD group. Specifically, the OHRQoL dimensions of functional limitation, physical pain, psychological discomfort, and psychological disability in the FP group, and functional limitation in the RP group, improved greatly in comparison with the CD group (P patient satisfaction than the CD treatment. Reliable information of OHRQoL and patient satisfaction helps experts and patients choose the best prosthetic treatment option. © 2014 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  12. Frequency and Type of Prosthetic Complications Associated with Interim, Immediately Loaded Full-Arch Prostheses: A 2-Year Retrospective Chart Review.

    Science.gov (United States)

    Drago, Carl

    2016-08-01

    The purpose of this report was to retrospectively evaluate implant and immediate full-arch prosthesis survival rates over a 24-month period; patients were consecutively treated with immediate occlusal loading. Dental arch, gender, and implant orientation (vertical vs. tilted) were also noted. All Brånemark System implants (Nobel Active) and interim, all-acrylic resin prostheses placed in patients following an All-on-Four™ protocol, in a single private practice were assessed by retrospective patient chart review. The amount of space provided surgically for implant restorative components and prostheses was determined from measurements of the vertical heights of the interim prostheses in the right/left anterior and posterior segments. These measurements were made in the laboratory. Interim prosthetic repairs (type, frequency, length of time from insertion) were analyzed by type, arch, gender, and implant orientation. Implant survival and insertion torque values were also measured. Inclusion criteria consisted of all Brånemark System implants placed with the All-on-Four protocol from September 1, 2011, until August 31, 2013. Specific dietary instructions were given for the first 7 days immediately postoperatively and for the weeks prior to insertion of the definitive prostheses. One hundred twenty-nine patients, comprising 191 arches (766 implants) from September 1, 2011, until August 31, 2013, were included in the study. One patient experienced implant failure yielding an overall implant survival rate (SR) of 99.5% (762 of 766). Four hundred twenty-six of 430 maxillary implants and 336 of 336 mandibular implants survived for SRs of 99.1% and 100%, respectively. Regarding implant orientation, 415 of 417 tilted implants (SR 99.5%) and 343 of 345 (CSR 95.6%) vertical implants were noted to be clinically stable. Interim, all-acrylic resin prostheses were in place for a mean of 199.2 days; mandibular prostheses were in place for an average of 195.4 days; maxillary

  13. Functional changes through the usage of 3D-printed transitional prostheses in children.

    Science.gov (United States)

    Zuniga, Jorge M; Peck, Jean L; Srivastava, Rakesh; Pierce, James E; Dudley, Drew R; Than, Nicholas A; Stergiou, Nicholas

    2017-11-08

    There is limited knowledge on the use of 3 D-printed transitional prostheses, as they relate to changes in function and strength. Therefore, the purpose of this study was to identify functional and strength changes after usage of 3 D-printed transitional prostheses for multiple weeks for children with upper-limb differences. Gross manual dexterity was assessed using the Box and Block Test and wrist strength was measured using a dynamometer. This testing was conducted before and after a period of 24 ± 2.61 weeks of using a 3 D-printed transitional prosthesis. The 11 children (five girls and six boys; 3-15 years of age) who participated in the study, were fitted with a 3 D-printed transitional partial hand (n = 9) or an arm (n = 2) prosthesis. Separate two-way repeated measures ANOVAs were performed to analyze function and strength data. There was a significant hand by time interaction for function, but not for strength. Conclusion and relevance to the study of disability and rehabilitation: The increase in manual gross dexterity suggests that the Cyborg Beast 2 3 D-printed prosthesis can be used as a transitional device to improve function in children with traumatic or congenital upper-limb differences. Implications for Rehabilitation Children's prosthetic needs are complex due to their small size, rapid growth, and psychosocial development. Advancements in computer-aided design and additive manufacturing offer the possibility of designing and printing transitional prostheses at a very low cost, but there is limited knowledge on the function of this type of devices. The use of 3D printed transitional prostheses may improve manual gross dexterity in children after several weeks of using it.

  14. Application of quality by design for 3D printed bone prostheses and scaffolds.

    Science.gov (United States)

    Martinez-Marquez, Daniel; Mirnajafizadeh, Ali; Carty, Christopher P; Stewart, Rodney A

    2018-01-01

    3D printing is an emergent manufacturing technology recently being applied in the medical field for the development of custom bone prostheses and scaffolds. However, successful industry transformation to this new design and manufacturing approach requires technology integration, concurrent multi-disciplinary collaboration, and a robust quality management framework. This latter change enabler is the focus of this study. While a number of comprehensive quality frameworks have been developed in recent decades to ensure that the manufacturing of medical devices produces reliable products, they are centred on the traditional context of standardised manufacturing techniques. The advent of 3D printing technologies and the prospects for mass customisation provides significant market opportunities, but also presents a serious challenge to regulatory bodies tasked with managing and assuring product quality and safety. Before 3D printing bone prostheses and scaffolds can gain traction, industry stakeholders, such as regulators, clients, medical practitioners, insurers, lawyers, and manufacturers, would all require a high degree of confidence that customised manufacturing can achieve the same quality outcomes as standardised manufacturing. A Quality by Design (QbD) approach to custom 3D printed prostheses can help to ensure that products are designed and manufactured correctly from the beginning without errors. This paper reports on the adaptation of the QbD approach for the development process of 3D printed custom bone prosthesis and scaffolds. This was achieved through the identification of the Critical Quality Attributes of such products, and an extensive review of different design and fabrication methods for 3D printed bone prostheses. Research outcomes include the development of a comprehensive design and fabrication process flow diagram, and categorised risks associated with the design and fabrication processes of such products. An extensive systematic literature review

  15. Application of quality by design for 3D printed bone prostheses and scaffolds

    Science.gov (United States)

    Martinez-Marquez, Daniel; Mirnajafizadeh, Ali; Carty, Christopher P.

    2018-01-01

    3D printing is an emergent manufacturing technology recently being applied in the medical field for the development of custom bone prostheses and scaffolds. However, successful industry transformation to this new design and manufacturing approach requires technology integration, concurrent multi-disciplinary collaboration, and a robust quality management framework. This latter change enabler is the focus of this study. While a number of comprehensive quality frameworks have been developed in recent decades to ensure that the manufacturing of medical devices produces reliable products, they are centred on the traditional context of standardised manufacturing techniques. The advent of 3D printing technologies and the prospects for mass customisation provides significant market opportunities, but also presents a serious challenge to regulatory bodies tasked with managing and assuring product quality and safety. Before 3D printing bone prostheses and scaffolds can gain traction, industry stakeholders, such as regulators, clients, medical practitioners, insurers, lawyers, and manufacturers, would all require a high degree of confidence that customised manufacturing can achieve the same quality outcomes as standardised manufacturing. A Quality by Design (QbD) approach to custom 3D printed prostheses can help to ensure that products are designed and manufactured correctly from the beginning without errors. This paper reports on the adaptation of the QbD approach for the development process of 3D printed custom bone prosthesis and scaffolds. This was achieved through the identification of the Critical Quality Attributes of such products, and an extensive review of different design and fabrication methods for 3D printed bone prostheses. Research outcomes include the development of a comprehensive design and fabrication process flow diagram, and categorised risks associated with the design and fabrication processes of such products. An extensive systematic literature review

  16. Cross-pinning: the philosophy of retrievability applied practically to fixed, implant-supported prostheses.

    Science.gov (United States)

    Gervais, M J; Hatzipanagiotis, P; Wilson, P R

    2008-03-01

    Biologic and technical complications are widely reported in the dental literature and often compromise the functional and/or aesthetic features of fixed, implant-supported prostheses. Managing complications without damaging or destroying a restoration is an obvious advantage of implant-based dentistry where the option of prosthetic retrievability is almost always available. The technique of cross-pinning uses a transverse screw to secure a prosthesis to a milled implant abutment, allowing prosthetic retrievability irrespective of dental implant alignment. This study presents guidelines for cross-pinning implant-supported prostheses based on resistance form, screw mechanics and natural tooth contours. The technical aspects of cross-pinning are also discussed using examples from four implant systems.

  17. 19 mm sized bileaflet valve prostheses' flow field investigated by bidimensional laser Doppler anemometry (part II: maximum turbulent shear stresses)

    Science.gov (United States)

    Barbaro, V; Grigioni, M; Daniele, C; D'Avenio, G; Boccanera, G

    1997-11-01

    The investigation of the flow field generated by cardiac valve prostheses is a necessary task to gain knowledge on the possible relationship between turbulence-derived stresses and the hemolytic and thrombogenic complications in patients after valve replacement. The study of turbulence flows downstream of cardiac prostheses, in literature, especially concerns large-sized prostheses with a variable flow regime from very low up to 6 L/min. The Food and Drug Administration draft guidance requires the study of the minimum prosthetic size at a high cardiac output to reach the maximum Reynolds number conditions. Within the framework of a national research project regarding the characterization of cardiovascular endoprostheses, an in-depth study of turbulence generated downstream of bileaflet cardiac valves is currently under way at the Laboratory of Biomedical Engineering of the Istituto Superiore di Sanita. Four models of 19 mm bileaflet valve prostheses were used: St Jude Medical HP, Edwards Tekna, Sorin Bicarbon, and CarboMedics. The prostheses were selected for the nominal Tissue Annulus Diameter as reported by manufacturers without any assessment of valve sizing method, and were mounted in aortic position. The aortic geometry was scaled for 19 mm prostheses using angiographic data. The turbulence-derived shear stresses were investigated very close to the valve (0.35 D0), using a bidimensional Laser Doppler anemometry system and applying the Principal Stress Analysis. Results concern typical turbulence quantities during a 50 ms window at peak flow in the systolic phase. Conclusions are drawn regarding the turbulence associated to valve design features, as well as the possible damage to blood constituents.

  18. Biomedical Titanium alloy prostheses manufacturing by means of Superplastic and Incremental Forming processes

    Directory of Open Access Journals (Sweden)

    Piccininni Antonio

    2016-01-01

    Full Text Available The present work collects some results of the three-years Research Program “BioForming“, funded by the Italian Ministry of Education (MIUR and aimed to investigate the possibility of using flexible sheet forming processes, i.e. Super Plastic Forming (SPF and Single Point Incremental Forming (SPIF, for the manufacturing of patient-oriented titanium prostheses. The prosthetic implants used as case studies were from the skull; in particular, two different Ti alloys and geometries were considered: one to be produced in Ti-Gr23 by SPF and one to be produced in Ti-Gr2 by SPIF. Numerical simulations implementing material behaviours evaluated by characterization tests were conducted in order to design both the manufacturing processes. Subsequently, experimental tests were carried out implementing numerical results in terms of: (i gas pressure profile able to determine a constant (and optimal strain rate during the SPF process; (ii tool path able to avoid rupture during the SPIF process. Post forming characteristics of the prostheses in terms of thickness distributions were measured and compared to data from simulations for validation purposes. A good correlation between numerical and experimental thickness distributions has been obtained; in addition, the possibility of successfully adopting both the SPF and the SPIF processes for the manufacturing of prostheses has been demonstrated.

  19. In vitro comparative analysis of the fit of gold alloy or commercially pure titanium implant-supported prostheses before and after electroerosion.

    Science.gov (United States)

    Sartori, Ivete Aparecida de Mattias; Ribeiro, Ricardo Faria; Francischone, Carlos Eduardo; de Mattos, Maria da Gloria Chiarello

    2004-08-01

    For implant-supported prostheses, passive fit is critical for the success of rehabilitation, especially when alternative materials are used. The purpose of this study was to compare interfacial fit of implant-supported prostheses cast in titanium to those cast in gold alloy. Five 3-unit fixed partial dentures were fabricated in gold alloy (Degudent U) as 1-piece castings, and 5 others were similarly cast in commercially pure titanium (Grade 1). The interfacial gaps between the prostheses and the abutments were evaluated with an optical microscope, before and after electroerosion. Readings were made with both screws tightened (10 N.cm torque), and with only 1 side tightened, so as to also evaluate the passive fit of the prostheses. Data were compared statistically by 2-way analysis of variance and the post hoc Tukey multiple range test (alpha=.05). Before electroerosion, the interfacial gaps for the 1-piece prostheses were significantly smaller (Pelectroerosion procedure significantly (Pelectroerosion did not present significant differences when the side opposite the tightened side was analyzed, but the gold alloy group showed better fit when the tightened side was analyzed (12.8 +/- 1.4 microm for gold alloy; 29.6 +/- 4.4 microm for titanium) and when both screws were tightened (5.4 +/- 2.3 microm for gold alloy; 16.1 +/- 5.5 microm for titanium). Cast titanium prostheses, despite showing larger interfacial gaps between the prosthesis and abutment than those obtained with gold alloy, had improved fit after being subjected to electroerosion.

  20. Immunoscintigraphy with antigranulocyte monoclonal antibodies for the diagnosis of septic loosening of hip prostheses

    International Nuclear Information System (INIS)

    Boubaker, A.; Bischof Delaloye, A.; Blanc, C.H.; Dutoit, M.; Leyvraz, P.F.; Delaloye, B.

    1995-01-01

    To determine the value of immunoscintigraphy (IS) with antigranulocyte monoclonal antibodies (Mab) in the diagnosis of subacute or chronic infection of hip prostheses, we prospectively studied 57 patients (23 women and 34 men; age 29-92 years, mean 72.7 years) sent to our institution in the past 6 years for clinical suspicion of septic loosening of a hip prosthesis. Nineteen patients had bilateral prostheses and one of them was studied twice. A total of 78 prostheses were examined. All patients had three-phase bone scans followed by IS with technetium-99m antigranulocyte Mab BW 250/183. Intervals between bone scans and IS varied from 2 days to 4 weeks. Final diagnosis was assessed by culture in 48 cases (articular puncture or intraoperative sampling) and by clinical follow-up of at least 8 months in 30 cases. Twelve prostheses were considered septic and 66 non-septic. The overall sensitivity and specificity were 92% and 64% respectively for bone scans, 67% and 75% for IS and 67% and 84% for both modalities together. In three cases, IS was doubtful and the final clinical diagnosis was negative for infection. False-positive results were observed in the presence of massive loosening of the prosthesis or in association with metaplastic peri-articular bone formation. In three of the four false-negative results, infection was proven only after enrichment of the culture, and the bacterium was Staphylococcus epidermidis. In 12/33 (36%) positive bone scans IS allowed the diagnosis of infection to be excluded. Overall accuracy of both modalities together was 81% and the negative predictive value was 93%, which compares favourably with the results reported for other non-invasive methods. (orig.)

  1. IMPROVED HEALING OF SMALL-CALIBER POLYTETRAFLUOROETHYLENE PROSTHESES BY INDUCTION OF A CLOT LAYER - A REVIEW OF EXPERIMENTAL STUDIES IN RATS

    NARCIS (Netherlands)

    VANDERLEI, B; STRONCK, JW; WILDEVUUR, CRH

    1991-01-01

    This report reviews our experiments that have been undertaken to test the hypothesis whether the induction of a clot layer on the graft surface of small-caliber polytetrafluoroethylene ( PTFE) prostheses might improve their healing. 1 2 PTFE prostheses with a fibril length of 30-mu-m, PTFE

  2. Efficacy of cleansing agents in killing microorganisms in mixed species biofilms present on silicone facial prostheses-an in vitro study

    NARCIS (Netherlands)

    Ariani, Nina; Visser, Anita; Teulings, Margot R. I. M.; Dijk, Melissa; Rahardjo, Tri Budi W.; Vissink, Arjan; van der Mei, Henny C.

    2015-01-01

    The purpose of this study was to assess the efficacy of different cleansing agents in killing mixed species biofilms on silicone facial prostheses. Two bacterial and three yeast strains, isolated from silicone facial prostheses, were selected for the mixed species biofilms. A variety of agents used

  3. Manufacturing Implant Supported Auricular Prostheses by Rapid Prototyping Techniques

    OpenAIRE

    Karatas, Meltem Ozdemir; Cifter, Ebru Demet; Ozenen, Didem Ozdemir; Balik, Ali; Tuncer, Erman Bulent

    2011-01-01

    Maxillofacial prostheses are usually fabricated on the models obtained following the impression procedures. Disadvantages of conventional impression techniques used in production of facial prosthesis are deformation of soft tissues caused by impression material and disturbance of the patient due to. Additionally production of prosthesis by conventional methods takes longer time. Recently, rapid prototyping techniques have been developed for extraoral prosthesis in order to reduce these disadv...

  4. Control Capabilities of Myoelectric Robotic Prostheses by Hand Amputees: A Scientific Research and Market Overview.

    Science.gov (United States)

    Atzori, Manfredo; Müller, Henning

    2015-01-01

    Hand amputation can dramatically affect the capabilities of a person. Cortical reorganization occurs in the brain, but the motor and somatosensorial cortex can interact with the remnant muscles of the missing hand even many years after the amputation, leading to the possibility to restore the capabilities of hand amputees through myoelectric prostheses. Myoelectric hand prostheses with many degrees of freedom are commercially available and recent advances in rehabilitation robotics suggest that their natural control can be performed in real life. The first commercial products exploiting pattern recognition to recognize the movements have recently been released, however the most common control systems are still usually unnatural and must be learned through long training. Dexterous and naturally controlled robotic prostheses can become reality in the everyday life of amputees but the path still requires many steps. This mini-review aims to improve the situation by giving an overview of the advancements in the commercial and scientific domains in order to outline the current and future chances in this field and to foster the integration between market and scientific research.

  5. Control Capabilities of Myoelectric Robotic Prostheses by Hand Amputees: A Scientific Research and Market Overview

    Directory of Open Access Journals (Sweden)

    Manfredo eAtzori

    2015-11-01

    Full Text Available Hand amputation can dramatically affect the capabilities of a person. Cortical reorganization occurs in the brain, but the motor and somatosensorial cortex can interact with the remnant muscles of the missing hand even many years after the amputation, leading to the possibility to restore the capabilities of hand amputees through myoelectric prostheses. Myoelectric hand prostheses with many degrees of freedom are commercially available and recent advances in rehabilitation robotics suggest that their natural control can be performed in real life. The first commercial products exploiting pattern recognition to recognize the movements have recently been released, however the most common control systems are still usually unnatural and must be learned through long training. Dexterous and naturally controlled robotic prostheses can become reality in the everyday life of amputees but the path still requires many steps. This mini-review aims to improve the situation by giving an overview of the advancements in the commercial and scientific domains in order to outline the current and future chances in this field and to foster the integration between market and scientific research.

  6. Stress analysis in oral obturator prostheses, part II: photoelastic imaging

    Science.gov (United States)

    Pesqueira, Aldiéris Alves; Goiato, Marcelo Coelho; da Silva, Emily Vivianne Freitas; Haddad, Marcela Filié; Moreno, Amália; Zahoui, Abbas; dos Santos, Daniela Micheline

    2014-06-01

    In part I of the study, two attachment systems [O-ring; bar-clip (BC)] were used, and the system with three individualized O-rings provided the lowest stress on the implants and the support tissues. Therefore, the aim of this study was to assess the stress distribution, through the photoelastic method, on implant-retained palatal obturator prostheses associated with different attachment systems: BOC-splinted implants with a bar connected to two centrally placed O-rings, and BOD-splinted implants with a BC connected to two distally placed O-rings (cantilever). One photoelastic model of the maxilla with oral-sinus-nasal communication with three parallel implants was fabricated. Afterward, two implant-retained palatal obturator prostheses with the two attachment systems described above were constructed. Each assembly was positioned in a circular polariscope and a 100-N axial load was applied in three different regions with implants by using a universal testing machine. The results were obtained through photograph record analysis of stress. The BOD system exhibited the highest stress concentration, followed by the BOC system. The O-ring, centrally placed on the bar, allows higher mobility of the prostheses and homogeneously distributes the stress to the region of the alveolar ridge and implants. It can be concluded that the use of implants with O-rings, isolated or connected with a bar, to rehabilitate maxillectomized patients allows higher prosthesis mobility and homogeneously distributes the stress to the alveolar ridge region, which may result in greater chewing stress distribution to implants and bone tissue. The clinical implication of the augmented bone support loss after maxillectomy is the increase of stress in the attachment systems and, consequently, a higher tendency for displacement of the prosthesis.

  7. Implant-supported titanium prostheses following augmentation procedures: a clinical report.

    Science.gov (United States)

    Knabe, C; Hoffmeister, B

    2003-03-01

    This report describes a novel technique for fabricating retrievable implant-supported titanium (Ti) prostheses in patients requiring a comprehensive treatment plan involving the combined efforts of maxillofacial surgery and implant prosthodontics. Following bone graft reconstructive surgery and implant placement prosthetic treatment was initiated by inserting ITI-Octa abutments. An impression was made, and a framework was fabricated by fusing Ti-cast frameworks to prefabricated titanium copings by laser-welding. This was followed by veneering or fabrication of a removable denture with Ti metal re-enforcement. Favourable clinical results have been achieved using these screw-retained Ti implant-supported restorations for patients treated with reconstructive bone graft-surgery, with clinical observation periods ranging from three to four years. The present observations suggest that these screw-retained implant-supported Ti prostheses may be a meaningful contribution to implant prosthodontics, facilitating retrievable restorations of optimum biocompatibility, good marginal precision and with a good esthetic result. However, controlled clinical studies are needed to establish the long-term serviceability of these Ti restorations.

  8. Electromyography data for non-invasive naturally-controlled robotic hand prostheses.

    Science.gov (United States)

    Atzori, Manfredo; Gijsberts, Arjan; Castellini, Claudio; Caputo, Barbara; Hager, Anne-Gabrielle Mittaz; Elsig, Simone; Giatsidis, Giorgio; Bassetto, Franco; Müller, Henning

    2014-01-01

    Recent advances in rehabilitation robotics suggest that it may be possible for hand-amputated subjects to recover at least a significant part of the lost hand functionality. The control of robotic prosthetic hands using non-invasive techniques is still a challenge in real life: myoelectric prostheses give limited control capabilities, the control is often unnatural and must be learned through long training times. Meanwhile, scientific literature results are promising but they are still far from fulfilling real-life needs. This work aims to close this gap by allowing worldwide research groups to develop and test movement recognition and force control algorithms on a benchmark scientific database. The database is targeted at studying the relationship between surface electromyography, hand kinematics and hand forces, with the final goal of developing non-invasive, naturally controlled, robotic hand prostheses. The validation section verifies that the data are similar to data acquired in real-life conditions, and that recognition of different hand tasks by applying state-of-the-art signal features and machine-learning algorithms is possible.

  9. A biodegradable gentamicin-hydroxyapatite-coating for infection prophylaxis in cementless hip prostheses

    Directory of Open Access Journals (Sweden)

    D Neut

    2015-01-01

    Full Text Available A degradable, poly (lactic-co-glycolic acid (PLGA, gentamicin-loaded prophylactic coating for hydroxyapatite (HA-coated cementless hip prostheses is developed with similar antibacterial efficacy as offered by gentamicin-loaded cements for fixing traditional, cemented prostheses in bone. We describe the development pathway, from in vitro investigation of antibiotic release and antibacterial properties of this PLGA-gentamicin-HA-coating in different in vitro models to an evaluation of its efficacy in preventing implant-related infection in rabbits. Bone in-growth in the absence and presence of the coating was investigated in a canine model. The PLGA-gentamicin-HA-coating showed high-burst release, with antibacterial efficacy in agar-assays completely disappearing after 4 days, minimising risk of inducing antibiotic resistance. Gentamicin-sensitive and gentamicin-resistant staphylococci were killed by the antibiotic-loaded coating, in a simulated prosthesis-related interfacial gap. PLGA-gentamicin-HA-coatings prevented growth of bioluminescent staphylococci around a miniature-stem mounted in bacterially contaminated agar, as observed using bio-optical imaging. PLGA-gentamicin-HA-coated pins inserted in bacterially contaminated medullary canals in rabbits caused a statistically significant reduction in infection rates compared to HA-coated pins without gentamicin. Bone ingrowth to PLGA-gentamicin-HA-coated pins, in condylar defects of Beagle dogs was not impaired by the presence of the degradable, gentamicin-loaded coating. In conclusion, the PLGA-gentamicin-HA-coating constitutes an effective strategy for infection prophylaxis in cementless prostheses.

  10. Radial Force: An Underestimated Parameter in Oversizing Transcatheter Aortic Valve Replacement Prostheses: In Vitro Analysis with Five Commercialized Valves.

    Science.gov (United States)

    Egron, Sandrine; Fujita, Buntaro; Gullón, Lucía; Désirée, Pott; Schmitz-Rode, Thomas; Ensminger, Stephan; Steinseifer, Ulrich

    2017-09-05

    The goal is to inform in depth on transcatheter aortic valve replacement (TAVR) prosthesis mechanical behavior, depending on frame type, design, and size, and how it crucially impacts the oversizing issue in clinical use, and ultimately the procedure outcome. Transcatheter aortic valve replacement is an established therapy for high-risk patients suffering from aortic stenosis, and the indication for TAVR is progressively expanding to intermediate-risk patients. Choosing the optimal oversizing degree is crucial to safely anchor the TAVR valve-which involves limiting the risks for embolism, aortic regurgitation, conductance disturbance, or annulus rupture-and to increase the valve prosthesis performance. The radial force (RF) profiles of five TAVR prostheses were measured in vitro: the CoreValve 23 and 26 (Medtronic, MN), the Acurate neo S (Symetis, Switzerland), and the SAPIEN XT 23 and 26 (Edwards Lifesciences, CA). Measurements were run with the RX Machine equipment (Machine Solutions Inc., AZ), which is used in ISO standard tests for intravascular stents. Test protocols were adapted for TAVR prostheses. With the prostheses RF profiles' results, mechanical behavior differences could be described and discussed in terms of oversizing strategy and clinical impact for all five valves. Besides, crossing the prostheses' RF profiles with their recommended size windows made the assessment of borderline size cases possible and helped analyze the risks when accurate measurement of patient aortic annulus proves difficult. The prostheses' RF profiles bring new support in clinical decision-making for valve type and size in patients.

  11. [Technical aspects of treatments with single- and multi-unit fixed dental prostheses

    NARCIS (Netherlands)

    Wiersema, E.J.; Kreulen, C.M.; Latzke, P.; Witter, D.J.; Creugers, N.H.J.

    2014-01-01

    For the manufacture of single- and multi-unit fixed dental prostheses, effective communication between dentist and dental technician is required. Mutual insight concerning the (im)possibilities of available treatments and technical options is prerequisitefor this communication. The manufacture of

  12. Stimulation and recording electrodes for neural prostheses

    CERN Document Server

    Pour Aryan, Naser; Rothermel, Albrecht

    2015-01-01

    This book provides readers with basic principles of the electrochemistry of the electrodes used in modern, implantable neural prostheses. The authors discuss the boundaries and conditions in which the electrodes continue to function properly for long time spans, which are required when designing neural stimulator devices for long-term in vivo applications. Two kinds of electrode materials, titanium nitride and iridium are discussed extensively, both qualitatively and quantitatively. The influence of the counter electrode on the safety margins and electrode lifetime in a two electrode system is explained. Electrode modeling is handled in a final chapter.

  13. Clinical and Radiographic Assessment of Reasons for Replacement of Metal- Ceramic Fixed Dental Prostheses in Patients Referring to Dental School.

    Science.gov (United States)

    Al Refai, Roa'a; Saker, Samah

    2018-01-01

    The expected length of service and reasons for fixed dental prostheses (FDPs) replacement are a frequent inquiry by patients while the answers were mainly based on studies reports that was conducted outside the middle east region. This clinical and radiographic survey was constructed to assess and survey clinically and radiographically the reasons of replacement of metal-ceramic fixed dental prostheses, amongst patients reporting at dental school in Taibah University. Between January and May 2016, 151 patients were recruited for this study. Interview (include questions pertained to the length of service of the prosthesis, the nature of complaint as told by patient in her own words), clinical examination, intra-oral photographs, and periapical radiographs, were done by the researchers. The parameters assessed were secondary caries, open margins, loss of retention, failure of endodontic treatment of the abutment and periodontal diseases. A total number of 249 failed fixed dental prostheses were evaluated. Of which 180 (39.7%) were single crowns, 159 (35.0%) were retainers and 117 (25.8%) were pontics in 69 fixed partial denture. The most common reason for replacement of fixed restorations was periodontal diseases affecting 92.8% of all types' restorations, followed by defective margin in 90.4% of examined restoration, poor aesthetic in 88% of restorations, while periapical involvement was found in 85.5% of fixed dental prosthesis. The survival rates of fixed prostheses were not predictable, and no association was found between number of years in service and the number of restorations. The most common reasons for replacing single unit fixed dental prostheses are periodontal diseases and periapical involvement, while defective margins and poor aesthetic mainly associated with multi-unit fixed dental prostheses. Key words: Failure, Fixed dental prosthesis, Survival, Replacement.

  14. Evaluation of Osseous Integration of PVD-Silver-Coated Hip Prostheses in a Canine Model

    Directory of Open Access Journals (Sweden)

    Gregor Hauschild

    2015-01-01

    Full Text Available Infection associated with biomaterials used for orthopedic prostheses remains a serious complication in orthopedics, especially tumor surgery. Silver-coating of orthopedic (megaprostheses proved its efficiency in reducing infections but has been limited to surface areas exposed to soft tissues due to concerns of silver inhibiting osseous integration of cementless stems. To close this gap in the bactericidal capacity of silver-coated orthopedic prostheses extension of the silver-coating on surface areas intended for osseous integration seems to be inevitable. Our study reports about a PVD- (physical-vapor-deposition- silver-coated cementless stem in a canine model for the first time and showed osseous integration of a silver-coated titanium surface in vivo. Radiological, histological, and biomechanical analysis revealed a stable osseous integration of four of nine stems implanted. Silver trace elemental concentrations in serum did not exceed 1.82 parts per billion (ppb and can be considered as nontoxic. Changes in liver and kidney functions associated with the silver-coating could be excluded by blood chemistry analysis. This was in accordance with very limited metal displacement from coated surfaces observed by laser ablation inductively coupled plasma-mass spectrometry (LA-ICP-MS 12 months after implantation. In conclusion our results represent a step towards complete bactericidal silver-coating of orthopedic prostheses.

  15. Oral Implant-Prostheses: New Teeth for a Brighter Brain.

    Directory of Open Access Journals (Sweden)

    Vincenzo De Cicco

    Full Text Available Several studies have demonstrated that chewing can be regarded as a preventive measure for cognitive impairment, whereas masticatory deficiency, associated with soft-diet feeding, is a risk factor for the development of dementia. At present the link between orofacial sensorimotor activity and cognitive functions is unknown. In subjects with unilateral molar loss we have shown asymmetries in both pupil size and masticatory muscles electromyographic (EMG activity during clenching: the molar less side was characterized by a lower EMG activity and a smaller pupil. Since implant-prostheses, greatly reduced both the asymmetry in EMG activity and in pupil's size, trigeminal unbalance, leading to unbalance in the activity of the Locus Coeruleus (LC, may be responsible for the pupil's asymmetry. According to the findings obtained in animal models, we propose that the different activity of the right and left LC may induce an asymmetry in brain activity, thus leading to cognitive impairment. According to this hypothesis, prostheses improved the performance in a complex sensorimotor task and increased the mydriasis associated with haptic tasks. In conclusion, the present study indicates that the implant-prosthesis therapy, which reduces the unbalance of trigeminal proprioceptive afferents and the asymmetry in pupil's size, may improve arousal, boosting performance in a complex sensorimotor task.

  16. Workflow Optimization for Tuning Prostheses with High Input Channel

    Science.gov (United States)

    2017-10-01

    of Specific Aim 1 by driving a commercially available two DoF wrist and single DoF hand. The high -level control system will provide analog signals...AWARD NUMBER: W81XWH-16-1-0767 TITLE: Workflow Optimization for Tuning Prostheses with High Input Channel PRINCIPAL INVESTIGATOR: Daniel Merrill...Unlimited The views, opinions and/or findings contained in this report are those of the author(s) and should not be construed as an official Department

  17. Fixed and mobile-bearing total ankle prostheses: Effect on tibial bone strain.

    Science.gov (United States)

    Terrier, Alexandre; Fernandes, Caroline Sieger; Guillemin, Maïka; Crevoisier, Xavier

    2017-10-01

    Total ankle replacement is associated to a high revision rate. To improve implant survival, the potential advantage of prostheses with fixed bearing compared to mobile bearing is unclear. The objective of this study was to test the hypothesis that fixed and mobile bearing prostheses are associated with different biomechanical quantities typically associated to implant failure. With a validated finite element model, we compared three cases: a prosthesis with a fixed bearing, a prosthesis with a mobile bearing in a centered position, and a prosthesis with mobile bearing in an eccentric position. Both prostheses were obtained from the same manufacturer. They were tested on seven tibias with maximum axial compression force during walking. We tested the hypothesis that there was a difference of bone strain, bone-implant interfacial stress, and bone support between the three cases. We also evaluated, for the three cases, the correlations between bone support, bone strain and bone-implant interfacial stress. There were no statistically significant differences between the three cases. Overall, bone support was mainly trabecular, and less effective in the posterior side. Bone strain and bone-implant interfacial stress were strongly correlated to bone support. Even if slight differences are observed between fixed and mobile bearing, it is not enough to put forward the superiority of one of these implants regarding their reaction to axial compression. When associated to the published clinical results, our study provides no argument to warn surgeons against the use of two-components fixed bearing implants. Copyright © 2017 Elsevier Ltd. All rights reserved.

  18. HEALING OF MICROVENOUS PTFE PROSTHESES IMPLANTED INTO THE RAT FEMORAL VEIN

    NARCIS (Netherlands)

    VANDERLEI, B; DIJK, F; JONGEBLOED, WL; ROBINSON, PH; Bartels, H.

    44 PTFE prostheses (Gore-Tex(R); ID 1 mm) were implanted into rats' femoral veins by means of the sleeve anastomotic technique and were evaluated at regular intervals from 1 h up till 24 weeks after implantation by means of light and electron microscopy to study in detail their healing process. All

  19. Tribology of total hip arthroplasty prostheses

    Science.gov (United States)

    Rieker, Claude B.

    2016-01-01

    Articulating components should minimise the generation of wear particles in order to optimize long-term survival of the prosthesis. A good understanding of tribological properties helps the orthopaedic surgeon to choose the most suitable bearing for each individual patient. Conventional and highly cross-linked polyethylene articulating either with metal or ceramic, ceramic-on-ceramic and metal-on-metal are the most commonly used bearing combinations. All combinations of bearing surface have their advantages and disadvantages. An appraisal of the individual patient’s objectives should be part of the assessment of the best bearing surface. Cite this article: Rieker CB. Tribology of total hip arthroplasty prostheses: what an orthopaedic surgeon should know. EFORT Open Rev 2016;1:52-57. DOI: 10.1302/2058-5241.1.000004. PMID:28461928

  20. Provisional prostheses during ridge augmentation and implant dentistry.

    Science.gov (United States)

    Livada, Rania; Hottel, Timothy L; Shiloah, Jacob

    2013-01-01

    Recent advancements in ridge augmentation and bone regeneration have expanded the pool of patients that could benefit from dental implants. However, providing the patient with a temporary prosthesis during the wound healing phase without impairing the process is a challenging task. This article summarizes available information pertaining to provisional prostheses, both tooth-supported and soft tissue-supported, that may meet the patient needs. The advantages and disadvantages of each class of prosthesis, along with indications and contraindications, were taken into consideration to aid the restorative dentist in choosing the optimal provisional for their patients.

  1. [Clinical characteristics of the Soviet low-profile heart valve prostheses EMIKS and LIKS].

    Science.gov (United States)

    Tsukerman, G I; Dobrova, N B; Faminskiĭ, D O; Pomortseva, L V; Gvakhariia, I N; Chigogidze, N A; Zaretskiĭ, Iu V

    1989-01-01

    The present work is devoted to the clinical assessment of the Soviet-made cardiac valve prostheses 'EMIKS' and 'LIKS'. From 1983 to May 1, 1988, 632 prostheses were implanted to 508 patients. A group of 348 patients were assessed: 139 after mitral (M) replacement, 130 after aortal (A) replacement, and 79 after mitral-aortal (M+A) replacement. Hospital mortality rate was: in M group--4.3 per cent, in A group--5.3 per cent, in M+A group--8.8 per cent. Survival rate on the fifth postoperative year was: in M group--89.5 +/- 9.2 per cent, in a group--90.0 +/- 4.2 per cent, in M+A group--91.0 +/- 6.2 per cent, the stability of the good results being 85.5 +/- 7.2, 79.5 +/- 6.2, and 75.0 +/- 9.1 per cent, respectively. At year 5 of the follow-up, patient numbers without thromboembolic complications amounted to 95.0 +/- 4.7 per cent in M group, 95.5 +/- 4.2 per cent in A group, and 85.0 +/- 9.1 in M+A group. 95.1 per cent patients belong to functional classes I and II. In mitral replacement, the mean 'EMIKS' gradient was 4.2 +/- 0.58 mm Hg, the 'LIKS' one--4.58 +/- 0.62 mm Hg. Intravascular hemolysis was not observed. The 'EMIKS' and 'LIKS' prostheses match the models produced in other countries. No significant differences between the two models were found.

  2. Screening of patients for first time prostheses after amputation of lower limbs

    Directory of Open Access Journals (Sweden)

    Vetra A.

    2016-01-01

    More than 25% of those who followed the recommended treatment and rehabilitation programme to prepare the amputation stump, reduced contracture and enhanced physical working abilities were declared to be appropriate for further prostheses. This indicates serious shortcomings in medical treatments during the early post-amputation period.

  3. Pathogenic characteristics of Candida albicans isolated from oral cavities of denture wearers and cancer patients wearing oral prostheses.

    Science.gov (United States)

    Mothibe, J V; Patel, M

    2017-09-01

    Candida albicans cause opportunistic infections including oral candidiasis in immunocompromised patients. It has an ability to cause infection due to its virulence factors. This study investigated the pathogenic characteristics of C. albicans isolated from the oral cavities of healthy subjects and two vulnerable groups, denture wearers and cancer patients wearing oral prostheses. Oral rinse samples were collected and cultured for the quantitative and qualitative analysis of Candida. Twenty strains of C. albicans isolated from the healthy individuals and denture wearers and, 14 strains isolated from the cancer patients were selected and their pathogenic characteristics were measured. The results of the study groups were compared using a Scheffe test for pairwise comparison and a chi square test. Denture wearer and cancer patients with prostheses carried significantly higher number (p production were significantly higher in the strains from denture wearers. In addition, high number of isolates from the denture wearers produced phospholipase and proteinase (85% and 80% respectively) compared to the strains from normal subjects (25% and 60% respectively). Only the germ tube formation and adherence ability were significantly higher in the strains from the cancer patients with prostheses (p = 0.05 and p oral cavity and prostheses is important in the prevention of colonization of Candida and the development of oral candidiasis. Copyright © 2017 Elsevier Ltd. All rights reserved.

  4. Progressive recovery of osseoperception as a function of the combination of implant-supported prostheses.

    Science.gov (United States)

    Batista, Mauro; Bonachela, Wellington; Soares, Janir

    2008-06-01

    The extraction of teeth involves the elimination of extremely sensitive periodontal mechanoreceptors, which play an important role in oral sensory perception. The aim of this study was to evaluate the recovery of interocclusal sensory perception for micro-thickness in individuals with different types of implant-supported prostheses. Wearers of complete dentures (CDs) comprised the negative control group (group A, n=17). The experimental group consisted of wearers of prostheses supported by osseointegrated implants (Group B, n=29), which was subsequently divided into 4 subgroups: B(1) (n=5)--implant supported overdentures (ISO) occluding with CD; B(2) (n=6)--implant-supported fixed prostheses (ISFP) occluding with CD; B(3) (n=8)--wearers of maxillary and mandibular ISFP, and B(4) (n=10)--ISFP occluding with natural dentition (ND). Individuals with ND represented the positive control group (Group C, n=24). Aluminum foils measuring 10 microm, 24 microm, 30 microm, 50 microm, 80 microm, and 104 microm thickness were placed within the premolar area, adding up to 120 tests for each individual. The mean tactile thresholds of groups A, B1, B2, B3, B4, and C were 92 microm, 27 microm, 27 microm, 14 microm, 10 microm, and 10 microm, respectively. [Correction added after publication online 18 April 2008: in the preceding sentence 92 microm, 27 microm, 14 microm, 10 microm and 10 microm, was corrected to 92 microm, 27 microm, 27 microm, 14 microm, 10 microm and 10 microm]. The Kruskal-Wallis test revealed significant difference among groups (P<0.05). The Dunn test revealed that group A was statistically different from groups C, B(3), and B(4), and that B(1) and B(2) were statistically different from group C. Progressive recovery of osseoperception as a function of the combination of implant-supported prostheses could be observed. Moreover, ISO and/or ISFP combinations may similarly maximize the recovery of osseoperception.

  5. [Loading and strength of single- and multi-unit fixed dental prostheses 2. Strength

    NARCIS (Netherlands)

    Baat, C. de; Witter, D.J.; Meijers, C.C.A.J.; Vergoossen, E.L.; Creugers, N.H.J.

    2014-01-01

    The ultimate strength of a dental prosthesis is defined as the strongest loading force applied to the prosthesis until afracture failure occurs. Important key terms are strength, hardness, toughness and fatigue. Relatively prevalent complications of single- and multi-unit fixed dental prostheses are

  6. Auditory Neural Prostheses – A Window to the Future

    Directory of Open Access Journals (Sweden)

    Mohan Kameshwaran

    2015-06-01

    Full Text Available Hearing loss is one of the commonest congenital anomalies to affect children world-over. The incidence of congenital hearing loss is more pronounced in developing countries like the Indian sub-continent, especially with the problems of consanguinity. Hearing loss is a double tragedy, as it leads to not only deafness but also language deprivation. However, hearing loss is the only truly remediable handicap, due to remarkable advances in biomedical engineering and surgical techniques. Auditory neural prostheses help to augment or restore hearing by integration of an external circuitry with the peripheral hearing apparatus and the central circuitry of the brain. A cochlear implant (CI is a surgically implantable device that helps restore hearing in patients with severe-profound hearing loss, unresponsive to amplification by conventional hearing aids. CIs are electronic devices designed to detect mechanical sound energy and convert it into electrical signals that can be delivered to the coch­lear nerve, bypassing the damaged hair cells of the coch­lea. The only true prerequisite is an intact auditory nerve. The emphasis is on implantation as early as possible to maximize speech understanding and perception. Bilateral CI has significant benefits which include improved speech perception in noisy environments and improved sound localization. Presently, the indications for CI have widened and these expanded indications for implantation are related to age, additional handicaps, residual hearing, and special etiologies of deafness. Combined electric and acoustic stimulation (EAS / hybrid device is designed for individuals with binaural low-frequency hearing and severe-to-profound high-frequency hearing loss. Auditory brainstem implantation (ABI is a safe and effective means of hearing rehabilitation in patients with retrocochlear disorders, such as neurofibromatosis type 2 (NF2 or congenital cochlear nerve aplasia, wherein the cochlear nerve is damaged

  7. Force Myography to Control Robotic Upper Extremity Prostheses: A Feasibility Study

    Directory of Open Access Journals (Sweden)

    Erina eCho

    2016-03-01

    Full Text Available Advancement in assistive technology has led to the commercial availability of multi-dexterous robotic prostheses for the upper extremity. The relatively low performance of the currently used techniques to detect the intention of the user to control such advanced robotic prostheses, however, limits their use. This article explores the use of force myography (FMG as a potential alternative to the well-established surface electro-myography (sEMG. Specifically, the use of FMG to control different grips of a commercially available robotic hand, Bebionic3, are investigated. Four male transradially amputated subjects participated in the study and a protocol was developed to assess the prediction accuracy of eleven grips. Different combinations of grips were examined ranging from six up to eleven grips. The results indicate that it is possible to classify six primary grips important in activities of daily living using FMG with an accuracy of above 70% in the residual limb. Additional strategies to increase classification accuracy, such as using the available modes on the Bebionic3, allowed results to improve up to 88.83% and 89.00% for opposed thumb and non-opposed thumb modes respectively.

  8. Neuromuscular coordination of masticatory muscles in subjects with two types of implant-supported prostheses.

    Science.gov (United States)

    Ferrario, Virgilio F; Tartaglia, Gianluca M; Maglione, Michele; Simion, Massimo; Sforza, Chiarella

    2004-04-01

    To compare the electromyographic (EMG) characteristics of masticatory muscles in patients with fixed implant-supported prostheses and implant overdentures. Nineteen subjects aged 45-79 years were examined. Fourteen were edentulous and had been successfully rehabilitated with (a) maxillary and mandibular implant-supported fixed prostheses (seven patients); (b) mandibular implant overdentures and maxillary complete dentures (seven patients). Five control subjects had natural dentition or single/partial (no more than two teeth) tooth or implant fixed dentures. Surface EMG of the masseter and temporal muscles was performed during unilateral gum chewing and during maximum teeth clenching. To reduce biological and instrumental noise, all values were standardized as percentage of a maximum clenching on cotton rolls. During clenching, temporal muscle symmetry was larger in control subjects and fixed implant-supported prosthesis patients than in overdenture patients (analysis of variance, P=0.005). No differences were found in masseter muscle symmetry or in muscular torque. Muscle activities (integrated areas of the EMG potentials over time) were significantly larger in control subjects than in implant-supported prosthesis patients (P=0.014). In both patient groups, a poor neuromuscular coordination during chewing, with altered muscular patterns, and a smaller left-right symmetry than in control subjects were found (P=0.05). No differences in masticatory frequency were found. Surface EMG analysis of clenching and chewing showed that fixed implant-supported prostheses and implant overdentures were functionally equivalent. Neuromuscular coordination during chewing was inferior to that found in subjects with natural dentition.

  9. 3D surface reconstruction and FIB microscopy of worn alumina hip prostheses

    Energy Technology Data Exchange (ETDEWEB)

    Zeng, P; Inkson, B J; Rainforth, W M [Department of Engineering Materials, Mappin St., University of Sheffield, Sheffield, S1 3JD (United Kingdom); Stewart, T [School of Mechanical Engineering, University of Leeds, Leeds, LS2 9JT (United Kingdom)], E-mail: m.rainforth@sheffield.ac.uk

    2008-08-15

    Interest in alumina-on-alumina total hip replacements (THR) continues to grow for the young and active patient due to their superior wear performance and biocompatibility compared to the alternative traditional polymer/metal prostheses. While alumina on alumina bearings offer an excellent solution, a region of high wear, known as stripe wear, is commonly observed on retrieved alumina hip components that poses concern. These in-vivo stripe wear mechanisms can be replicated in vitro by the introduction of micro-separation during the simulated walking cycle in hip joint simulation. However, the understanding of the mechanisms behind the stripe wear processes is relatively poor. 3D topographic reconstructions of titled SEM stereo pairs from different zones have been obtained to determine the local worn surface topography. Focused ion beam (FIB) microscopy was applied to examine the subsurface damage across the stripe wear. The paper presents novel images of sub-surface microcracks in alumina along with 3D reconstructions of the worn ceramic surfaces and a classification of four distinct wear zones following microseparation in hip prostheses.

  10. Prosthesis use in adult acquired major upper-limb amputees: patterns of wear, prosthetic skills and the actual use of prostheses in activities of daily life.

    Science.gov (United States)

    Østlie, Kristin; Lesjø, Ingrid Marie; Franklin, Rosemary Joy; Garfelt, Beate; Skjeldal, Ola Hunsbeth; Magnus, Per

    2012-11-01

    To describe patterns of prosthesis wear and perceived prosthetic usefulness in adult acquired upper-limb amputees (ULAs). To describe prosthetic skills in activities of daily life (ADL) and the actual use of prostheses in the performance of ADL tasks. To estimate the influence of prosthetic skills on actual prosthesis use and the influence of background factors on prosthetic skills and actual prosthesis use. Cross-sectional study analysing population-based questionnaire data (n = 224) and data from interviews and clinical testing in a referred/convenience sample of prosthesis-wearing ULAs (n = 50). Effects were analysed using linear regression. 80.8% wore prostheses. 90.3% reported their most worn prosthesis as useful. Prosthetic usefulness profiles varied with prosthetic type. Despite demonstrating good prosthetic skills, the amputees reported actual prosthesis use in only about half of the ADL tasks performed in everyday life. In unilateral amputees, increased actual use was associated with sufficient prosthetic training and with the use of myoelectric vs cosmetic prostheses, regardless of amputation level. Prosthetic skills did not affect actual prosthesis use. No background factors showed significant effect on prosthetic skills. Most major ULAs wear prostheses. Individualised prosthetic training and fitting of myoelectric rather than passive prostheses may increase actual prosthesis use in ADL.

  11. Edentulous patients' knowledge of dental hygiene and care of prostheses.

    Science.gov (United States)

    de Castellucci Barbosa, Luciano; Ferreira, Manoela Rejane Maia; de Carvalho Calabrich, Carolina Freire; Viana, Aline Cavalcanti; de Lemos, Maria Catarina Lavigne; Lauria, Roberta Andrade

    2008-06-01

    The aim of this study was to analyse denture users' oral care habits with regard to the use of their prostheses. Rehabilitative treatment is only successful when patients are motivated and aware of correct prosthesis use and hygiene. Questionnaires were distributed to 150 complete denture users at the Federal University of Bahia School of Dentistry, the Esmeralda Natividade Health Center, the Bahian Science Development Foundation and a Salvador nursing home. The questionnaire included information on gender, age, length of prosthesis use, cleaning methods and materials, etc. The data were analysed using EpiInfo version 6 software. The chi-squared test was used for statistical analysis, with a significance level of 5%. Questionnaire results showed that 78% of the subjects, with an average age of 67.3 years, had used the same complete denture for over 5 years. 64% slept with their prostheses and 44% removed them from the mouth only for cleaning. None of the patients interviewed knew anything about brushes designed specifically for complete dentures. 37.3% had a restricted diet and 44% believed that a complete denture would last for more than 10 years. Within the limitations of this study, it was concluded that the edentulous patients surveyed had limited awareness of prosthetic hygiene and long-term oral care despite extended periods of denture use.

  12. [Aftercare for durability and profitability of single-unit and multi-unit fixed dental prostheses

    NARCIS (Netherlands)

    Baat, C. de; Loveren, C. van; Maarel-Wierink, C.D. van der; Witter, D.J.; Creugers, N.H.J.

    2013-01-01

    An important aim ofa treatment with single-unit and multi-unit fixed dental prostheses is a durable and profitable treatment outcome. That requires aftercare, too. First, the frequency of routine oral examinations should be assessed, using an individual risk profile. The objectives of the routine

  13. Modified Design of Pin-on-Ring Tribometer for Hip Joint Prostheses Measurement; Case Study on Salat Activity

    Directory of Open Access Journals (Sweden)

    Muhammad Khafidh

    2015-02-01

    Full Text Available Total hip replacement (THR is one of the most successful orthopedic surgical procedures for replacing a broken hip joint. In THR, wear may occur at the articulating surface of the acetabular cup and the femoral head. In Indonesia, the country with the largest Muslim population in the world, most of the inhabitants do salat (praying every day. THR users are banned from doing salat for fear it will damage the hip joint prostheses. The previous wear calculation methods on the hip joint prostheses use the gravimetric, coordinate measuring machine (CMM, profiler, and geometric method. The disadvantages of the previous methods are that the geometry of the wear patch and the wear volume are only known at the end of the experiment, so they cannot be used to calculate the specific wear rate values in real time. So far, in every modeling of the hip joint prostheses, the values of the specific wear rate are assumed to be constant. This paper reports on the design modification of a pin-on-ring tribometer that is used to measure the wear volumes in hip joint prostheses. The result shows that modifications of the femoral head holder, reciprocating motion, elastic joint, and extra displacement transducer is needed to get the specific wear rate value. The calculation method to find the delta volume that is the value of displacement less than the displacement minimum (δmin is based on a graph, while the calculation method to find the delta volume that is the value of displacement that is more than the displacement minimum (δmin is based on an equation. In the salat test protocol, the longest test time was during the sujud (prostration motion, which took 1034.17 minutes in the experiment.

  14. How good are our impressions? An audit of alginate impression quality in the production of removable prostheses.

    Science.gov (United States)

    Horwitz, Richard

    2014-05-01

    Impressions are taken regularly in practice giving vital information to the dental laboratory, but are there quality assurance systems in place to make sure that they are up to a sufficient standard? As dental professionals we have to appreciate that dental technicians can only work with the information given to them. This makes the skill of taking a good impression vital in order for us as clinicians to provide prostheses of good quality. This paper outlines an audit of alginate impressions and their quality in the making of removable prostheses. To record the quality of impression taking, and how one's own ability to critique an impression may differ from that of our colleagues.

  15. Fracture load of complete-arch implant-supported prostheses reinforced with nylon-silica mesh: An in vitro study.

    Science.gov (United States)

    Gonçalves, Fernanda de Cássia Papaiz; Amaral, Marina; Borges, Alexandre Luiz Souto; Gonçalves, Luiz Fernando Martins; Paes-Junior, Tarcisio José de Arruda

    2018-04-01

    Complete-arch implant-supported prostheses without a framework have a high risk of failure: a straightforward and inexpensive reinforcement material, such as nylon mesh, could improve their longevity. The purpose of this in vitro study was to evaluate a nylon-silica mesh compound on the fracture strength of acrylic resin and the fracture load of complete-arch implant-supported prostheses. Twenty-four complete mandibular arch implant-supported prostheses were divided into 2 groups according to cantilever length (molar and premolar) and subdivided into another 2 subgroups according to the presence or absence of reinforcing mesh. The specimens were submitted to a maximum load-to-fracture test in a universal testing machine, with a 100-N load cell, a 2 mm/min crosshead speed, and a spherical metal tip diameter of 4 mm at different points (molar and premolar). These were submitted to 1-way analysis of variance for repeated measurement and the post hoc Tukey multiple comparison test (α=.05). The mean maximum load ±standard deviation for the molar group was 393.4 ±95.0 N with reinforcement and 305.4 ±76.3 N without reinforcement (P=.02); and for the premolar group was 1083.3 ±283.7 N with reinforcement and 605.3 ±90.5 N without reinforcement (P=.001). Reinforcement with nylon mesh increased the mean maximum load of implant-supported complete-arch prostheses at both cantilever lengths. The cantilever to the premolar (5 mm) presented the highest maximum load values to fracture. Copyright © 2017 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.

  16. Aortic annulus eccentricity before and after transcatheter aortic valve implantation: Comparison of balloon-expandable and self-expanding prostheses

    International Nuclear Information System (INIS)

    Schuhbaeck, Annika; Weingartner, Christina; Arnold, Martin; Schmid, Jasmin; Pflederer, Tobias; Marwan, Mohamed; Rixe, Johannes; Nef, Holger; Schneider, Christian; Lell, Michael; Uder, Michael; Ensminger, Stephan; Feyrer, Richard; Weyand, Michael; Achenbach, Stephan

    2015-01-01

    Highlights: • Post-implant geometry of catheter-based aortic valve prostheses is influenced by aortic valve calcification. • Balloon-expandable prostheses are more circular as compared to self-expanding prostheses. • The impact of post-implant geometry on valve function needs to be investigated. - Abstract: Introduction: The geometry of the aortic annulus and implanted transcatheter aortic valve prosthesis might influence valve function. We investigated the influence of valve type and aortic valve calcification on post-implant geometry of catheter-based aortic valve prostheses. Methods: Eighty consecutive patients with severe aortic valve stenosis (mean age 82 ± 6 years) underwent computed tomography before and after TAVI. Aortic annulus diameters were determined. Influence of prosthesis type and degree of aortic valve calcification on post-implant eccentricity were analysed. Results: Aortic annulus eccentricity was reduced in patients after TAVI (0.21 ± 0.06 vs. 0.08 ± 0.06, p < 0.0001). Post-TAVI eccentricity was significantly lower in 65 patients following implantation of a balloon-expandable prosthesis as compared to 15 patients who received a self-expanding prosthesis (0.06 ± 0.05 vs. 0.15 ± 0.07, p < 0.0001), even though the extent of aortic valve calcification was not different. After TAVI, patients with a higher calcium amount retained a significantly higher eccentricity compared to patients with lower amounts of calcium. Conclusions: Patients undergoing TAVI with a balloon-expandable prosthesis show a more circular shape of the implanted prosthesis as compared to patients with a self-expanding prosthesis. Eccentricity of the deployed prosthesis is affected by the extent of aortic valve calcification

  17. Clinical Fit of Partial Removable Dental Prostheses Based on Alginate or Polyvinyl Siloxane Impressions.

    NARCIS (Netherlands)

    Fokkinga, W.A.; Witter, D.J.; Bronkhorst, E.M.; Creugers, N.H.J.

    2017-01-01

    PURPOSE: The aim of this study was to analyze the clinical fit of metal-frame partial removable dental prostheses (PRDPs) based on custom trays used with alginate or polyvinyl siloxane impression material. MATERIALS AND METHODS: Fifth-year students of the Nijmegen Dental School made 25 correct

  18. [Single- and multi-unit fixed dental prostheses in relation to the occlusal system].

    Science.gov (United States)

    Witter, D J; Gerritsen, A E; van Spijker, A; Creugers, N H J

    2013-02-01

    Occlusion concepts based on functional aspects offer more solid ground in the diagnostic process and in the treatment of (reduced) dentitions than morphologically and mechanically oriented occlusion concepts. Nevertheless, for occlusal reconstruction morphologically oriented guidelines are necessary. These guidelines are based on the border movements and positions of the mandible in the orofacial system, and on the location and modelling of the occlusal contacts in the occlusal system. The modelling of single- and multi-unit fixed dental prostheses must harmonize with the occlusal system. Moreover, an important feature is the relation of the anterior teeth which enables mutually protected occlusion. Characteristics of a healthy orofacial and occlusal system are: absence of pathology, perceived sufficient oral functions, variability inform and function, and adaptive capacity. When designing single- or multiunit fixed dental prostheses, a pragmatic starting point is to maintain the existing occlusion and the existing speech pattern unless arguments can be provided for alterations. The occlusal design should aim at optimizing oral functions, such as mandibular and occlusal stability.

  19. Investigation of firing temperature variation in ovens for ceramic-fused-to-metal dental prostheses using swept source optical coherence tomography

    Science.gov (United States)

    Todor, Raluca; Negrutiu, Meda-Lavinia; Sinescu, Cosmin; Topala, Florin Ionel; Bradu, Adrian; Duma, Virgil-Florin; Romînu, Mihai; Podoleanu, Adrian G.

    2018-03-01

    One of the most common fabrication techniques for dental ceramics is sintering, a process of heating of the ceramic to ensure densification. This occurs by viscous flow when the firing temperature is reached. Acceptable restorations require the alloy and ceramic to be chemically, thermally, mechanically, and aesthetically compatible. Thermal and mechanical compatibility include a fusing temperature of ceramic that does not cause distortion of the metal substructure. Decalibration of ovens used for firing of the ceramic layers for metal ceramic dental prostheses leads to stress and cracks in the veneering material, and ultimately to the failure of the restoration. 25 metal ceramic prostheses were made for this study. They were divided in five groups, each sintered at a different temperature: a group at the temperature prescribed by the producer, two groups at lower and two groups at higher temperatures set in the ceramic oven. An established noninvasive biomedical imaging method, swept source (SS) optical coherence tomography (OCT) was employed, in order to evaluate the modifications induced when using temperatures different from those prescribed for firing the samples. A quantitative assessment of the probes is performed by en-face OCT images, taken at constant depths inside the samples. The differences in granulation, thus in reflectivity allow for extracting rules-of-thumb to evaluate fast, by using only the prostheses currently produced the current calibration of the ceramic oven. OCT imaging can allow quick identification of the oven decalibration, to avoid producing dental prostheses with defects.

  20. A computer-based biomechanical analysis of the three-dimensional motion of cementless hip prostheses.

    Science.gov (United States)

    Gilbert, J L; Bloomfeld, R S; Lautenschlager, E P; Wixson, R L

    1992-04-01

    A computer-based mathematical technique was developed to measure and completely describe the migration and micromotion of a femoral hip prosthesis relative to the femur. This technique utilized the mechanics of rigid-body motion analysis and apparatus of seven linear displacement transducers to measure and describe the complete three-dimensional motion of the prosthesis during cyclic loading. Computer acquisition of the data and custom analysis software allowed one to calculate the magnitude and direction of the motion of any point of interest on the prostheses from information about the motion of two points on the device. The data were also used to replay the tests using a computer animation technique, which allowed a magnified view of the three-dimensional motion of the prosthesis. This paper describes the mathematical development of the rigid-body motion analysis, the experimental method and apparatus for data collection, the technique used to animate the motion, the sources of error and the effect of the assumptions (rigid bodies) on the results. Selected results of individual test runs of uncemented and cemented prostheses are presented to demonstrate the efficacy of the method. The combined effect of the vibration and electrical noise resulted in a resolution of the system of about 3-5 microns motion for each transducer. Deformation effects appear to contribute about 3-15 microns to the measurement error. This measurement and analysis technique is a very sensitive and powerful means of assessing the effects of different design parameters on the migration and micromotion of total joint prostheses and can be applied to any other case (knee, dental implant) where three-dimensional relative motion between two bodies is important.

  1. Whole-body angular momentum during stair walking using passive and powered lower-limb prostheses.

    Science.gov (United States)

    Pickle, Nathaniel T; Wilken, Jason M; Aldridge, Jennifer M; Neptune, Richard R; Silverman, Anne K

    2014-10-17

    Individuals with a unilateral transtibial amputation have a greater risk of falling compared to able-bodied individuals, and falling on stairs can lead to serious injuries. Individuals with transtibial amputations have lost ankle plantarflexor muscle function, which is critical for regulating whole-body angular momentum to maintain dynamic balance. Recently, powered prostheses have been designed to provide active ankle power generation with the goal of restoring biological ankle function. However, the effects of using a powered prosthesis on the regulation of whole-body angular momentum are unknown. The purpose of this study was to use angular momentum to evaluate dynamic balance in individuals with a transtibial amputation using powered and passive prostheses relative to able-bodied individuals during stair ascent and descent. Ground reaction forces, external moment arms, and joint powers were also investigated to interpret the angular momentum results. A key result was that individuals with an amputation had a larger range of sagittal-plane angular momentum during prosthetic limb stance compared to able-bodied individuals during stair ascent. There were no significant differences in the frontal, transverse, or sagittal-plane ranges of angular momentum or maximum magnitude of the angular momentum vector between the passive and powered prostheses during stair ascent or descent. These results indicate that individuals with an amputation have altered angular momentum trajectories during stair walking compared to able-bodied individuals, which may contribute to an increased fall risk. The results also suggest that a powered prosthesis provides no distinct advantage over a passive prosthesis in maintaining dynamic balance during stair walking. Copyright © 2014 Elsevier Ltd. All rights reserved.

  2. ENHANCED HEALING OF 30-MU-M GORE-TEX PTFE MICROARTERIAL PROSTHESES BY ALCOHOL-PRETREATMENT

    NARCIS (Netherlands)

    VANDERLEI, B; STRONCK, JW; WILDEVUUR, CRH

    1991-01-01

    Polytetrafluoroethylene (PTFE) microvascular prostheses with a fibril length of 30-mu-m were pretreated with alcohol (n = 18), implanted into the abdominal aorta of rats and were evaluated at 1 day (n = 3), 1 week (n = 3), 3 weeks (n = 6) and 6 weeks (n = 6) to determine whether alcohol-pretreatment

  3. Waterjet cutting of periprosthetic interface tissue in loosened hip prostheses: an in vitro feasibility study

    NARCIS (Netherlands)

    Kraaij, Gert; Tuijthof, Gabrielle J. M.; Dankelman, Jenny; Nelissen, Rob G. H. H.; Valstar, Edward R.

    2015-01-01

    Waterjet cutting technology is considered a promising technology to be used for minimally invasive removal of interface tissue surrounding aseptically loose hip prostheses. The goal of this study was to investigate the feasibility of waterjet cutting of interface tissue membrane. Waterjets with 0.2

  4. Noninvasive radioisotopic technique for detection of platelet deposition in mitral valve prostheses and quantitation of visceral microembolism in dogs

    International Nuclear Information System (INIS)

    Dewanjee, M.K.; Fuster, V.; Rao, S.A.; Forshaw, P.L.; Kaye, M.P.

    1983-01-01

    A noninvasive technique has been developed in the dog model for imaging, with a gamma camera, the platelet deposition on Bjoerk-Shiley mitral valve prostheses early postoperatively. At 25 hours after implantation of the prosthesis and 24 hours after intravenous administration of 400 to 500 microCi of platelets labeled with indium-111, the platelet deposition in the sewing ring and perivalvular cardiac tissue can be clearly delineated in a scintiphotograph. An in vitro technique was also developed for quantitation of visceral microemboli in brain, lungs, kidneys, and other tissues. Biodistribution of the labeled platelets was quantitated, and the tissue/blood radioactivity ratio was determined in 22 dogs in four groups: unoperated normal dogs, sham-operated dogs, prosthesis-implanted dogs, and prosthesis-implanted dogs treated with dipyridamole before and aspirin and dipyridamole immediately after operation. Fifteen to 20% of total platelets were consumed as a consequence of the surgical procedure. On quantitation, we found that platelet deposition on the components of the prostheses was significantly reduced in prosthesis-implanted animals treated with dipyridamole and aspirin when compared with prosthesis-implanted, untreated dogs. All prosthesis-implanted animals considered together had a twofold to fourfold increase in tissue/blood radioactivity ratio in comparison with unoperated and sham-operated animals, an indication that the viscera work as filters and trap platelet microemboli that are presumably produced in the region of the mitral valve prostheses. In the dog model, indium-111-labeled platelets thus provide a sensitive marker for noninvasive imaging of platelet deposition on mechanical mitral valve prostheses, in vitro evaluation of platelet microembolism in viscera, in vitro quantitation of surgical consumption of platelets, and evaluation of platelet-inhibitor drugs

  5. The development of artificial organs and prostheses worldwide and in the Ottoman Empire.

    Science.gov (United States)

    Birdane, Leman; Cingi, Cemal; Elçioğlu, Ömür; Muluk, Nuray Bayar

    2016-08-01

    An artificial organ or prosthesis is a man-made device that is implanted or integrated into a human to replace a natural organ. There were many historical steps in the development of artificial organs and prostheses. New surgical techniques, the development of prosthetic materials and the creative ideas of engineers led to progress in this field. © The European Society of Cardiology 2014.

  6. 19 mm sized bileaflet valve prostheses' flow field investigated by bidimensional laser Doppler anemometry (part I: velocity profiles).

    Science.gov (United States)

    Barbaro, V; Grigioni, M; Daniele, C; D'Avenio, G; Boccanera, G

    1997-11-01

    The investigation of the flow field downstream of a cardiac valve prosthesis is a well established task. In particular turbulence generation is of interest if damage to blood constituents is to be assessed. Several prosthetic valve flow studies are available in literature but they generally concern large-sized prostheses. The FDA draft guidance requires the study of the maximum Reynolds number conditions for a cardiac valve model to assess the worst case in turbulence by choosing both the minimum valve diameter and a high cardiac output value as protocol set up. Within the framework of a national research project regarding the characterization of cardiovascular endoprostheses, the Laboratory of Biomedical Engineering is currently conducting an in-depth study of turbulence generated downstream of bileaflet cardiac valves. Four models of 19 mm sized bileaflet valve prostheses, namely St Jude Medical HP Edwards Tekna, Sorin Bicarbon, and CarboMedics, were studied in aortic position. The prostheses were selected for the nominal annulus diameter reported by the manufacturers without any assessment of the valve sizing method. The hemodynamic function was investigated using a bidimensional LDA system. Results concern velocity profiles during the peak flow systolic phase, at high cardiac output regime, highlighting the different flow field features downstream of the four small-sized cardiac valves.

  7. Ranking of CT in persistent vertigo after implantation of stapes prostheses

    International Nuclear Information System (INIS)

    Koesling, S.; Woldag, K.; Meister, E.F.; Reschke, I.; Schulz, H.G.

    1995-01-01

    10 of 150 patients had persistent vertigo after implanation of stapes prostheses. These patients were evaluated by high resolution CT in the axial and coronal plane. Scans showed in all cases findings which related to the symptoms. The CT findings were proved intraoperatively in 9 cases. A new indirect sign of a perilymphatic fistula is described in form of an air bulla at the end of the prosthesis. Retympanotomy could be planned better with the help of HR-CT. (orig.) [de

  8. Creating natural-looking removable prostheses: combining art and science to imitate nature.

    Science.gov (United States)

    Patras, Michael; Kourtis, Stefanos; Sykaras, Nikitas

    2012-06-01

    Patient awareness of dental appearance has increased, resulting in more demanding esthetic requests. There is also strong evidence that increased esthetics is highly significant for complete denture acceptance and success. Taking notice of patients' perceptions of natural appearance and esthetics, the clinician can incorporate their preferences in the construction of individualized dentures that will be harmonized with their facial characteristics. Despite the evolution of materials and techniques, the vast majority of dentures still fail to look natural. Thus, producing prostheses that defy detection and successfully restore the appearance of edentulous patients remains a challenge for the clinician. This paper presents a clinical case where immediate loading of implants supporting a mandibular overdenture was combined with an opposing conventional maxillary denture to satisfy the high functional and esthetic demands of the patient. It also emphasizes the individualized esthetic performance through customization during their fabrication while taking into consideration the various clinical parameters affecting rehabilitation of the edentulous jaw. Implant-retained overdentures can significantly improve the patients' function. The esthetic performance of these restorations however, may not be satisfying the patients' expectations and demands. Customizing the artificial gingival areas and individual staining of the prefabricated acrylic teeth may improve the esthetic performance creating natural-looking removable prostheses. © 2011 Wiley Periodicals, Inc.

  9. Antibacterial Efficacy of a New Gentamicin-Coating for Cementless Prostheses Compared to Gentamicin-Loaded Bone Cement

    NARCIS (Netherlands)

    Neut, Danielle; Dijkstra, Rene J. B.; Thompson, Jonathan I.; van der Mei, Henny C.; Busscher, Henk J.

    Cementless prostheses are increasingly popular but require alternative prophylactic measures than the use of antibiotic-loaded bone cements. Here, we determine the 24-h growth inhibition of gentamicin-releasing coatings from grit-blasted and porous-coated titanium alloys, and compare their

  10. Inducing repetitive action potential firing in neurons via synthesized photoresponsive nanoscale cellular prostheses.

    Science.gov (United States)

    Lu, Siyuan; Madhukar, Anupam

    2013-02-01

    Recently we reported an analysis that examined the potential of synthesized photovoltaic functional abiotic nanosystems (PVFANs) to modulate membrane potential and activate action potential firing in neurons. Here we extend the analysis to delineate the requirements on the electronic energy levels and the attendant photophysical properties of the PVFANs to induce repetitive action potential under continuous light, a capability essential for the proposed potential application of PVFANs as retinal cellular prostheses to compensate for loss of photoreceptors. We find that repetitive action potential firing demands two basic characteristics in the electronic response of the PVFANs: an exponential dependence of the PVFAN excited state decay rate on the membrane potential and a three-state system such that, following photon absorption, the electron decay from the excited state to the ground state is via intermediate state(s) whose lifetime is comparable to the refractory time following an action potential. In this study, the potential of synthetic photovoltaic functional abiotic nanosystems (PVFANs) is examined under continuous light to modulate membrane potential and activate action potential firing in neurons with the proposed potential application of PVFANs as retinal cellular prostheses. Copyright © 2013 Elsevier Inc. All rights reserved.

  11. [Failure of zirconia-based prostheses on natural teeth and implants: focus on risk factors].

    Science.gov (United States)

    Dupont, N; Koenig, V; Vanheusden, A; Mainjot, A

    2014-01-01

    Cohesive fracture of the veneering ceramic (chipping) is the first cause of failure of zirconia-based prostheses on natural teeth and implants. Besides risk factors related to the material (thermal stresses generated during the manufacturing process, framework inappropriate design), there are some clinical risk factors, which can influence the restoration prognosis. Indeed, unfavorable occlusal relationships and/or the presence of parafunctions such as bruxism and clenching, which are frequent pathologies, engender significant overloading. A retrospective study was performed at the University Hospital Center (CHU) of Liege on 147 dental and implants prostheses, placed between May 2003 and January 2012. This study highlighted a significant correlation between chipping and the absence of an occlusal nightguard (p = 0.0048), the presence of a ceramic restoration as an antagonist (p = 0.013), the presence of occlusal parafunctions (p = 0.018), and the presence of implants as support of the restorations (p = 0.026). These results underline the importance of external stress and occlusal risk factors diagnosis, as the need to perform an occlusal nightguard to patients with parafunctions.

  12. Wear Distribution Detection of Knee Joint Prostheses by Means of 3D Optical Scanners

    Directory of Open Access Journals (Sweden)

    Saverio Affatato

    2017-03-01

    Full Text Available The objective of this study was to examine total knee polyethylene inserts from in vitro simulation to evaluate and display—using a 3D optical scanner—wear patterns and wear rates of inserts exposed to wear by means of simulators. Various sets of tibial inserts have been reconstructed by using optical scanners. With this in mind, the wear behavior of fixed and mobile bearing polyethylene knee configurations was investigated using a knee wear joint simulator. After the completion of the wear test, the polyethylene menisci were analyzed by an innovative 3D optical scanners in order to evaluate the 3D wear distribution on the prosthesis surface. This study implemented a new procedure for evaluating polyethylene bearings of joint prostheses obtained after in vitro wear tests and the proposed new approach allowed quantification of the contact zone on the geometry of total knee prostheses. The results of the present study showed that mobile TKPs (total knee prosthesis have lower wear resistance with respect to fixed TKPs.

  13. Toward Balance Recovery With Leg Prostheses Using Neuromuscular Model Control

    Science.gov (United States)

    Geyer, Hartmut

    2016-01-01

    Objective Lower limb amputees are at high risk of falling as current prosthetic legs provide only limited functionality for recovering balance after unexpected disturbances. For instance, the most established control method used on powered leg prostheses tracks local joint impedance functions without taking the global function of the leg in balance recovery into account. Here we explore an alternative control policy for powered transfemoral prostheses that considers the global leg function and is based on a neuromuscular model of human locomotion. Methods We adapt this model to describe and simulate an amputee walking with a powered prosthesis using the proposed control, and evaluate the gait robustness when confronted with rough ground and swing leg disturbances. We then implement and partially evaluate the resulting controller on a leg prosthesis prototype worn by a non-amputee user. Results In simulation, the proposed prosthesis control leads to gaits that are more robust than those obtained by the impedance control method. The initial hardware experiments with the prosthesis prototype show that the proposed control reproduces normal walking patterns qualitatively and effectively responds to disturbances in early and late swing. However, the response to mid-swing disturbances neither replicates human responses nor averts falls. Conclusions The neuromuscular model control is a promising alternative to existing prosthesis controls, although further research will need to improve on the initial implementation and determine how well these results transfer to amputee gait. Significance This work provides a potential avenue for future development of control policies that help improve amputee balance recovery. PMID:26315935

  14. [Loading and strength of single- and multi-unit fixed dental prostheses. 1. Retention and resistance

    NARCIS (Netherlands)

    Baat, C. de; Witter, D.J.; Meijers, C.C.A.J.; Vergoossen, E.L.; Creugers, N.H.J.

    2014-01-01

    The degree to which single- and multi-unit fixed dental prostheses are able to withstand loading forces is dependent, among other things, on the quality of their retention and resistance. The quality of the retention and resistance of the configuration of an abutment tooth prepared for a metal and

  15. Testicular prostheses in children: Is earlier better?

    Science.gov (United States)

    Peycelon, M; Rossignol, G; Muller, C O; Carricaburu, E; Philippe-Chomette, P; Paye-Jaouen, A; El Ghoneimi, A

    2016-08-01

    The absence of a testis occurs for various reasons in children, but testicular prosthesis implantation in children is uncommon. The optimal time for prosthesis placement is still unclear, and its complication rate has been poorly studied in children. The aim of this study was to determine the risk factors of complications in cases of testicular prosthesis implantation in children. A monocentric, retrospective review was performed of children implanted with a testicular prosthesis between 2008 and 2014. All implantations were performed through an inguinal incision with a standardized procedure. Children were divided into two groups depending on the interval after orchiectomy: (A) early implantation (delay between surgeries prosthesis implantation at the mean age of 14.7 years (range 9-18) (A, 14.3; B, 14.6) with a mean delay of 36.1 months (A, 1.3; B, 80.3). Indications were mainly spermatic cord torsion (27%), bilateral anorchia (27%), and testicular atrophy after cryptorchidism surgery (19.2%). Complications (10.5%) included two cases of extrusion, one infection and one migration. Patient 1 had a history of acute lymphoblastic leukemia with testicle relapse 2 years after induction therapy. High-dose chemotherapy, total body irradiation and bilateral orchiectomies were performed, and bilateral prostheses were implanted 12 years after the end of chemotherapy. Complications happened 85 days after surgery. Patient 2 was followed-up for a proximal hypospadias. The tunica vaginalis flap, which was used during a redo urethroplasty, lead to testicular atrophy. Thirteen years after the last penile surgery, a testicular prosthesis was placed through an inguinal incision, and extrusion occurred 203 days after surgery. Bacterial cultures of the prostheses were sterile and histological review showed no sign of granuloma or graft rejection. The complication rate was significantly higher if the delay between the two surgeries exceeded 1 year (P = 0.01). Indications of

  16. Preliminary observations on influence of dairy products on biofilm removal from silicone rubber voice prostheses in vitro

    NARCIS (Netherlands)

    Busscher, HJ; Free, RH; Van Weissenbruch, R; Albers, FWJ; Van der Mei, HC

    We determined oropharyngeal biofilm removal from silicone rubber voice prostheses in an artificial throat after perfusion with different commercially available dairy products, including buttermilk, Lactobacillus casei Shirota fermented milk (Yakult, Yakult Netherlands BV, Almere, The Netherlands),

  17. Heart valve prostheses: who protects our patients, and from what?

    Science.gov (United States)

    Beall, A C

    1977-01-01

    Phenomenal advances in the development of cardiac valve prostheses have taken place in less than two decades. However, the currently prevailing atmosphere of consumer protectionism in existence 20 years ago probably would have made such developments impossible. Recent passage of the Medical Device Amendments of 1976 (P.L. 94-295) will not only make future development extremely difficult, but also may force the field of cardiac valve replacement back into the era of the 1950s. Regulations implementing this legislation may be even more disastrous. It is time for someone to protect patients from their so-called protectors.

  18. Wear properties of alumina/zirconia composite ceramics for joint prostheses measured with an end-face apparatus.

    Science.gov (United States)

    Morita, Yusuke; Nakata, Kenichi; Kim, Yoon-Ho; Sekino, Tohru; Niihara, Koichi; Ikeuchi, Ken

    2004-01-01

    While only alumina is applied to all-ceramic joint prostheses at present, a stronger ceramic is required to prevent fracture and chipping due to impingement and stress concentration. Zirconia could be a potential substitute for alumina because it has high strength and fracture toughness. However, the wear of zirconia/zirconia combination is too high for clinical use. Although some investigations on composite ceramics revealed that mixing of different ceramics was able to improve the mechanical properties of ceramics, there are few reports about wear properties of composite ceramics for joint prosthesis. Since acetabular cup and femoral head of artificial hip joint are finished precisely, they indicate high geometric conformity. Therefore, wear test under flat contact was carried out with an end-face wear testing apparatus for four kinds of ceramics: alumina monolith, zirconia monolith, alumina-based composite ceramic, and zirconia based composite ceramic. Mean contact pressure was 10 MPa and sliding velocity was 40 mm/s. The wear test continued for 72 hours and total sliding distance was 10 km. After the test, the wear factor was calculated. Worn surfaces were observed with a scanning electron micrograph (SEM). The results of this wear test show that the wear factors of the both composite ceramics are similarly low and their mechanical properties are much better than those of the alumina monolith and the zirconia monolith. According to these results, it is predicted that joint prostheses of the composite ceramics are safer against break down and have longer lifetime compared with alumina/alumina joint prostheses.

  19. MR imaging of 22 Charnley-Mueller total hip prostheses

    International Nuclear Information System (INIS)

    Lemmens, J.A.M.; Ruijs, J.H.J.

    1986-01-01

    To find out whether MR imaging is contraindicated in patients with metallic implants or can be a routine diagnostic procedure, MR investigations in 18 patients with 22 Charnley-Mueller total hip prostheses were performed on a 0.5 T Gyroscan S 5, Philips. No adverse reactions during or post MR investigation were encountered. The imaging of the soft tissue was superior to CT and showed less distortion. The diagnosis of loosening, by detection of demarcation lines at the interfaces was at its best in the distal part of the femoral stem prosthesis and was poor in the acetabular component and in the upper part of the stem prosthesis due to artifacts. (orig.) [de

  20. PATENCY AND HEALING OF MICROVASCULAR PROSTHESES - A REVIEW OF 10 YEARS OF EXPERIMENTAL WORK IN GRONINGEN

    NARCIS (Netherlands)

    VANDERLEI, B; ROBINSON, PH

    1993-01-01

    From 1982 onwards, in Groningen, The Netherlands, we have worked on the experimental evaluation and development of microvascular prostheses in rats and rabbits. In this review article a systematic overview of this experimental work is presented and the results are discussed with regard to the

  1. Adaptation to prostheses among patients with major lower-limb amputations and its association with sociodemographic and clinical data

    Directory of Open Access Journals (Sweden)

    Marco Antonio Nunes

    Full Text Available CONTEXT AND OBJECTIVE: Lower-limb amputation compromises patients' independence and autonomy, and therefore they should be referred for rehabilitation in order to adapt to prostheses and regain autonomy. The aim here was to assess adaptation to prostheses among patients with major lower-limb amputations and its association with sociodemographic and clinical data. DESIGN AND SETTING: This was a cross-sectional study in the city of Aracaju, Brazil. METHODS: The patients were identified by primary healthcare teams. The inclusion criterion was that these should be patients who underwent major lower-limb amputations of any etiology. Associations between sociodemographic and clinical variables and the adaptation to lower-limb prostheses were assessed. RESULTS: 149 patients were examined. Adaptation to the prosthesis occurred in 40% (60/149 of them, but only 62% (37/60 were using it. Adaptation occurred more often among male patients (P = 0.017 and among those who had a higher educational level (P = 0.013, with a longer time since amputation (P = 0.049 and when the etiology was trauma (P = 0.003. The result from logistic regression analysis showed that only patients with low education (P = 0.031 were significantly associated with a lower frequency of adaptation to prostheses. CONCLUSION: It was found that patients with a low educational level became adapted to the prosthesis less frequently. CONTEXTO E OBJETIVO: A amputação de membros inferiores compromete a independência e a autonomia dos pacientes, por isso, eles devem ser encaminhados para a reabilitação para a adaptação das próteses e assim viabilizar a recuperação da autonomia. O objetivo foi avaliar a adaptação de prótese em pacientes com amputações maiores de membros inferiores e sua associação com dados sócio-demográficos e clínicos.

  2. [A scanning electron microscopy study of the surface of porous-textured breast implants and their capsules. Description of the "velcro" effect of porous-textured breast prostheses].

    Science.gov (United States)

    Danino, A; Rocher, F; Blanchet-Bardon, C; Revol, M; Servant, J M

    2001-02-01

    The efficacy of breast prosthesis texturing in the prevention of capsular contracture has been established for about 20 years. This successful procedure has led to the development and marketing of a number of different models. In the present study, four porous-textured breast prostheses have been examined: the Arion monoblock implant, the CUI (McGahn), the Biocell (Mcgahn), and the Sebbin LS21. Scanning electron microscopic (SEM) investigation of the implant surfaces of the different prostheses was carried out on new samples received from the manufacturers. During a prospective study on eight patients, capsule samples corresponding to the four above-mentioned prostheses were taken to determine whether a secondary intervention was necessary for correction of asymmetry or malpositioning. These samples were analyzed by SEM to investigate whether there could be a correlation between prosthesis texturing and the aspect of the corresponding capsules. Significant ultrastructural differences were found between the various prostheses examined: the results showed that only the CUI and Biocell prostheses presented a mirror image of the capsule texturing, with a correspondence between the depressions on the prosthesis and the contacts on the capsule. This finding seems to be linked to the existence of a critical size for the pores that constitute the implant surface. This observation led to the hypothesis of an adhesive "velcro" effect between the prosthesis and its capsule. Although the latter may not be directly linked to the prevention of capsular contracture it can, however, have a major effect on implant stabilization in cases of primary breast reconstruction and in possible secondary adjustments of asymmetry and malpositioning.

  3. The stereognostic ability of natural dentitions versus implant-supported fixed prostheses or overdentures.

    Science.gov (United States)

    Jacobs, R; Bou Serhal, C; van Steenberghe, D

    1997-06-01

    A stereognostic ability test was performed in 60 patients. Forty patients were rehabilitated by means of osseointegrated implants. One group consisted of 20 patients with fixed prostheses on implants in both the upper and lower jaws. The other 20 patients had a maxillary denture while in the mandible an overdenture was retained by means of two implants connected by a bar. They were compared to a group of 20 subjects (controls) with a non-restored natural dentition. For the stereognostic ability test, subjects had to recognise ten different test pieces by manipulating them with two antagonistic incisor teeth, avoiding any contact with other oral structures. Both response time and percentage accuracy of recognition were evaluated. The present findings indicated that subjects with an overdenture on implants did not score significantly different from those with an implant-supported fixed prosthesis. In contrast, subjects with teeth had a significantly better stereognostic ability. The percentage of correct responses was 52% for overdentures, 56% for fixed prostheses on implants and 75% for natural dentitions. From these results, it could be concluded that the stereognostic ability is impaired in subjects rehabilitated with osseointegrated implants by about one-third to one-quarter compared to subjects with natural teeth.

  4. High-density EMG e-textile systems for the control of active prostheses

    DEFF Research Database (Denmark)

    Farina, Dario; Lorrain, Thomas; Negro, Francesco

    2010-01-01

    Myoelectric control of active prostheses requires electrode systems that are easy to apply for daily repositioning of the electrodes by the user. In this study we propose the use of Smart Fabric and Interactive Textile (SFIT) systems as an alternative solution for recording high-density EMG signa...... classified with linear discriminant analysis. The average classification accuracy for the nine tasks was 89.1 1.9 %. These results show that SFIT systems can be used as an effective way for muscle-machine interfacing....

  5. Neural prostheses in clinical applications--trends from precision mechanics towards biomedical microsystems in neurological rehabilitation.

    Science.gov (United States)

    Stieglitz, T; Schuettler, M; Koch, K P

    2004-04-01

    Neural prostheses partially restore body functions by technical nerve excitation after trauma or neurological diseases. External devices and implants have been developed since the early 1960s for many applications. Several systems have reached nowadays clinical practice: Cochlea implants help the deaf to hear, micturition is induced by bladder stimulators in paralyzed persons and deep brain stimulation helps patients with Parkinson's disease to participate in daily life again. So far, clinical neural prostheses are fabricated with means of precision mechanics. Since microsystem technology opens the opportunity to design and develop complex systems with a high number of electrodes to interface with the nervous systems, the opportunity for selective stimulation and complex implant scenarios seems to be feasible in the near future. The potentials and limitations with regard to biomedical microdevices are introduced and discussed in this paper. Target specifications are derived from existing implants and are discussed on selected applications that has been investigated in experimental research: a micromachined implant to interface a nerve stump with a sieve electrode, cuff electrodes with integrated electronics, and an epiretinal vision prosthesis.

  6. Wireless radio channel for intramuscular electrode implants in the control of upper limb prostheses.

    Science.gov (United States)

    Stango, Antonietta; Yazdandoost, Kamya Yekeh; Farina, Dario

    2015-01-01

    In the last few years the use of implanted devices has been considered also in the field of myoelectric hand prostheses. Wireless implanted EMG (Electromyogram) sensors can improve the functioning of the prosthesis, providing information without the disadvantage of the wires, and the usability by amputees. The solutions proposed in the literature are based on proprietary communication protocols between the implanted devices and the prosthesis controller, using frequency bands that are already assigned to other purposes. This study proposes the use of a standard communication protocol (IEEE 802.15.6), specific for wireless body area networks (WBANs), which assign a specific bandwidth to implanted devices. The propagation losses from in-to-on body were investigated by numerical simulation with a 3D human model and an electromagnetic solver. The channel model resulting from the study represents the first step towards the development of myoelectric prosthetic hands which are driven by signals acquired by implanted sensors. However these results can provide important information to researchers for further developments, and manufacturers, which can decrease the production costs for hand prostheses having a common standard of communication with assigned frequencies of operation.

  7. Dual-energy CT and ceramic or titanium prostheses material reduce CT artifacts and provide superior image quality of total knee arthroplasty.

    Science.gov (United States)

    Kasparek, Maximilian F; Töpker, Michael; Lazar, Mathias; Weber, Michael; Kasparek, Michael; Mang, Thomas; Apfaltrer, Paul; Kubista, Bernd; Windhager, Reinhard; Ringl, Helmut

    2018-06-07

    To evaluate the influence of different scan parameters for single-energy CT and dual-energy CT, as well as the impact of different material used in a TKA prosthesis on image quality and the extent of metal artifacts. Eight pairs of TKA prostheses from different vendors were examined in a phantom set-up. Each pair consisted of a conventional CoCr prosthesis and the corresponding anti-allergic prosthesis (full titanium, ceramic, or ceramic-coated) from the same vendor. Nine different (seven dual-energy CT and two single-energy CT) scan protocols with different characteristics were used to determine the most suitable CT protocol for TKA imaging. Quantitative image analysis included assessment of blooming artifacts (metal implants appear thicker on CT than they are, given as virtual growth in mm in this paper) and streak artifacts (thick dark lines around metal). Qualitative image analysis was used to investigate the bone-prosthesis interface. The full titanium prosthesis and full ceramic knee showed significantly fewer blooming artifacts compared to the standard CoCr prosthesis (mean virtual growth 0.6-2.2 mm compared to 2.9-4.6 mm, p energy CT protocols showed less blooming (range 3.3-3.8 mm) compared to single-energy protocols (4.6-5.5 mm). The full titanium and full ceramic prostheses showed significantly fewer streak artifacts (mean standard deviation 77-86 Hounsfield unit (HU)) compared to the standard CoCr prosthesis (277-334 HU, p energy CT protocols had fewer metal streak artifacts (215-296 HU compared to single-energy CT protocols (392-497 HU)). Full titanium and ceramic prostheses were ranked superior with regard to the image quality at the bone/prosthesis interface compared to a standard CoCr prosthesis, and all dual-energy CT protocols were ranked better than single-energy protocols. Dual-energy CT and ceramic or titanium prostheses reduce CT artifacts and provide superior image quality of total knee arthroplasty at the bone/prosthesis interface

  8. Motor behavior during the first chewing cycle in subjects with fixed tooth- or implant-supported prostheses.

    Science.gov (United States)

    Grigoriadis, Joannis; Trulsson, Mats; Svensson, Krister G

    2016-04-01

    Appropriate sensory information from periodontal mechanoreceptors (PMRs) is important for optimizing the positioning of food and adjustment of force vectors during precision biting. This study was designed to describe motor behavior during the first cycle of a natural chewing task and to evaluate the role of such sensory input in this behavior. While 10 subjects with natural dentition, 11 with bimaxillary fixed tooth-supported prostheses (TSP) and 10 with bimaxillary fixed implant-supported prostheses (ISP) (mean age 69 [range 61-83]) chewed a total of five hazelnuts, their vertical and lateral jaw movements were recorded. Data obtained during the first chewing cycle of each hazelnut were analyzed. The amplitude of vertical and lateral mandibular movement and duration of jaw opening did not differ between the groups, indicating similar behavior during this part of the chewing cycle. However, only 30% of the subjects in the natural dentate group, but 82% of those in the TSP and 70% in the ISP group exhibited slippage of the hazelnut during jaw closure in at least one of five trials. The TSP and ISP groups also exhibited more irregular and narrower patterns of motion (total lateral/vertical movement = 0.15 and 0.19, respectively, compared to 0.27 for the natural group). Subjects with fixed tooth- or implant-supported prostheses in both jaws show altered behavior, including inadequate control of the hazelnut, during the first chewing cycle. We propose that these differences are due to impairment or absence of sensory signaling from PMRs in these individuals. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  9. A fractographic study of clinically retrieved zirconia–ceramic and metal–ceramic fixed dental prostheses

    OpenAIRE

    Pang, Zhen; Chughtai, Asima; Sailer, Irena; Zhang, Yu

    2015-01-01

    A recent 3-year randomized controlled trial (RCT) of tooth supported three- to five-unit zirconia-ceramic and metal-ceramic posterior fixed dental prostheses (FDPs) revealed that veneer chipping and fracture in zirconia-ceramic systems occurred more frequently than those in metal-ceramic systems [1]. This study seeks to elucidate the underlying mechanisms responsible for the fracture phenomena observed in this RCT using a descriptive fractographic analysis

  10. Brachial plexus injury management through upper extremity amputation with immediate postoperative prostheses.

    Science.gov (United States)

    Malone, J M; Leal, J M; Underwood, J; Childers, S J

    1982-02-01

    Management of patients with brachial plexus injuries requires a team approach so that all aspects of their care are addressed simultaneously. This report examines elective amputation and prosthetic rehabilitation in a patient with brachial plexus avulsion of the left arm. The best possibility for good prosthetic rehabilitation is the early application of prosthetic devices with intensive occupational therapy. Using this type of approach, we have achieved significant improvement in amputation rehabilitation of upper extremity amputees treated with immediate postoperative conventional electric and myoelectric prostheses.

  11. Assessment of health-related quality of life in Turkish patients with facial prostheses

    Directory of Open Access Journals (Sweden)

    Atay Arzu

    2013-01-01

    Full Text Available Abstract Background Facial prostheses are intended to provide a non-operative rehabilitation for patients with acquired facial defects. By improving aesthetics and quality of life (QOL, this treatment involves reintegration of the patient into family and social life. The aim of this study was to evaluate the perception of QOL in adult patients with facial prostheses and to compare this perception with that of a control group. Methods The study participants consisted of 72 patients, who were divided into three equal-sized groups according to the type of prosthesis (OP- orbital prosthesis, AP- auricular prosthesis, NP - nasal prosthesis and 24 healthy control participants without any congenital or acquired deformity of face or body. Clinical and socio-demographic data were gathered from each person’s medical chart. Participants completed the Turkish version of the World Health Organization Quality of Life Instrument, Short Form (WHOQOL-BREF. Descriptive statistics, independent sample t-tests, Pearson's chi-square test, ANOVA, ANCOVA, and Pearson correlation were used to analyse the data. Results Compared with the control participants, patients with NP scored lower on the all domains of QOL and all three patient groups had lower scores on overall QOL and its domains of physical and environmental health. Patients with OP reported significantly lower physical health scores than those with AP, while patients with NP reported significantly lower overall QOL and psychological health scores than those with AP. Female patients had lower environmental domain scores than did male patients. The patient’s age and income correlated with social relationships QOL, while the patient’s income and the age of facial prosthesis were correlated with environmental QOL. Conclusion Patients with facial prostheses had lower scores in overall QOL, physical and environmental health domains than the control participants. Socio-demographic and clinical characteristics

  12. Anterior Cantilever Resin-Bonded Fixed Dental Prostheses: A Review of the Literature.

    Science.gov (United States)

    Mourshed, Bilal; Samran, Abdulaziz; Alfagih, Amal; Samran, Ahalm; Abdulrab, Saleem; Kern, Matthias

    2018-03-01

    This review evaluated the survival rate of single retainer anterior resin-bonded fixed dental prostheses (RBFDPs) to determine whether the choice of material affects their clinical outcome. An electronic search of the English peer-reviewed dental literature in PubMed was conducted to identify all publications reporting on cantilever RBFDPs until May 2016. Study information extraction and methodological quality assessments were accomplished by two reviewers independently. The searched keywords were as follows: "resin-bonded, single retainer, all-ceramic resin-bonded fixed dental prostheses (RBFDPs), all-ceramic RBFDPs, cantilever resin, RBFDPs, cantilever resin-bonded bridge, two units cantilevered, two-unit cantilevered, metal-ceramic cantilever, and metal-ceramic." Furthermore, the ''Related Articles'' feature of PubMed was used to identify further references of interest within the primary search. The bibliographies of the obtained references were used to identify pertinent secondary references. Review articles were also used to identify relevant articles. After the application of exclusion criteria, the definitive list of articles was screened to extract the qualitative data, and the results were analyzed. Overall 2588 articles were dedicated at the first review phase; however, only 311 studies were left after the elimination of duplicates and unrelated studies. Seventeen studies passed the second review phase. Five studies were excluded because they were follow-up studies of the same study cohort. Twelve studies were finally selected. The use of cantilever RBFDPs showed promising results and high survival rates. © 2016 by the American College of Prosthodontists.

  13. Human endothelium on vascular prostheses modified by extracellular matrix proteins in a flow experiment

    Czech Academy of Sciences Publication Activity Database

    Chlupáč, Jaroslav; Filová, Elena; Riedel, Tomáš; Brynda, Eduard; Remy-Zolghadri, M.; Bareille, R.; Fernandez, P.; Daculsi, R.; Bordenave, L.; Bačáková, Lucie

    2006-01-01

    Roč. 9, č. 58-60 (2006), s. 10-13 ISSN 1429-7248 R&D Projects: GA AV ČR(CZ) IAA5011301; GA AV ČR(CZ) IAA4050202; GA AV ČR(CZ) IAA400500507; GA AV ČR(CZ) 1QS500110564 Institutional research plan: CEZ:AV0Z50110509; CEZ:AV0Z40500505 Keywords : bioartificial vascular prostheses * laminin * fibrin Subject RIV: EI - Biotechnology ; Bionics

  14. Implant-tooth-supported fixed partial prostheses: correlations between in vivo occlusal bite forces and marginal bone reactions.

    Science.gov (United States)

    Akça, Kivanç; Uysal, Serdar; Cehreli, Murat Cavit

    2006-06-01

    To evaluate maximal occlusal bite forces (MOF) and marginal bone level (MBL) changes in patients with implant-tooth-supported fixed partial prostheses (FPP). Twenty nine partially edentulous patients consecutively who received 34 three-occlusal unit FPP with terminal implant and tooth support were subjected to quantification of MOFs using a sub-miniature load cell connected to a data acquisition system and measurement of the MBL changes around implants in digitalized periapical radiographs obtained at prostheses delivery and 24-month follow-up. MOFs for implant support (mean: 353.61 N) significantly differed from tooth support (mean: 275.48 N) (P 0.05). MBL changes at mesial and distal sites of the implants at 24 months of functional loading were 0.28 and 0.097 mm respectively. Although MOFs under functional loading might indicate an increase in load participation for supporting implant, the rigid connection between implant and natural tooth via three-occlusal unit FPP does not jeopardize the time-dependent MBL stability of the implant under functional loads.

  15. Cortical visual prostheses: from microstimulation to functional percept

    Science.gov (United States)

    Najarpour Foroushani, Armin; Pack, Christopher C.; Sawan, Mohamad

    2018-04-01

    Cortical visual prostheses are intended to restore vision by targeted electrical stimulation of the visual cortex. The perception of spots of light, called phosphenes, resulting from microstimulation of the visual pathway, suggests the possibility of creating meaningful percept made of phosphenes. However, to date electrical stimulation of V1 has still not resulted in perception of phosphenated images that goes beyond punctate spots of light. In this review, we summarize the clinical and experimental progress that has been made in generating phosphenes and modulating their associated perceptual characteristics in human and macaque primary visual cortex (V1). We focus specifically on the effects of different microstimulation parameters on perception and we analyse key challenges facing the generation of meaningful artificial percepts. Finally, we propose solutions to these challenges based on the application of supervised learning of population codes for spatial stimulation of visual cortex.

  16. Interference in adhesion of bacteria and yeasts isolated from explanted voice prostheses to silicone rubber by rhamnolipid biosurfactants

    NARCIS (Netherlands)

    Rodrigues, LR; Banat, IM; van der Mei, HC; Teixeira, JA; Oliveira, R

    Aims: The effects and extent of adhesion of four different bacterial and two yeast strains isolated from explanted voice prostheses to silicone rubber with and without an adsorbed rhamnolipid biosurfactant layer obtained from Pseudomonasaeruginosa DS10-129 was studied. Methods and Results: The

  17. Study of effects of metallic prostheses in radiotherapy treatments in prostate cancer; Estudio de los efectos de las protesis metalicas en tratamientos radioterapicos en irradiacion pelvica

    Energy Technology Data Exchange (ETDEWEB)

    Cabrera, P.; Mateos, J. C.; Herrador, M.; Ortiz, M. J.

    2006-07-01

    In this work it is described the problems related to the radiotherapy treatments of patients with prostate cancer and hip implants Analyze the effects of metallic prostheses in radiotherapy treatments and present the methods to overcome the problems that arise in these situations. Our patients are student in a TAC Philips with a range of Hounsfield number of-1000 to 4000. The planning and measurement of CT numbers are done in a RTP ADAC Pinnacle that have a maximum of 32767 CT units. The metallic implants more frequently used, titanium, stainless steel and cobalt-chromium-molybdenum, generate CT numbers from 2000 to 3000, and cause saturation effects. This problem may be solved with modern scanners that use the extended CT range. It is an algorithm that expand the usual range by a factor of 10. An alternative solution to this problem can be used if the prostheses are able to scan to select the window parameters that allow an automatic region of interest (roi) definition that match to the dimensions of the implants. Finally it is assigned the electronic/physical densities to the created roi's. The clinical dosimetry of patients with prostheses have been done defining the usual regions of interests (target volume and risk organs) in first place. Finally the prostheses are outlined using the window parameters previously measured and assigned the electronic or physical densities. The attenuation of the implant may then be calculated accurately. The presence of implants in the treatment fields originate artifacts in the TAC images of patients and underdosage of target volume that range between 12% and 30% in function of material an energy used. It is necessary the application of methods that correct the dose behind the implant, if it is not possible to prevent the incidence of the treatment beams over the prostheses. (Author)

  18. ELECTROMYOGRAPHIC EVALUATION OF MASTICATION AND SWALLOWING IN ELDERLY INDIVIDUALS WITH MANDIBULAR FIXED IMPLANTSUPPORTED PROSTHESES

    Science.gov (United States)

    Berretin-Felix, Giédre; Nary, Hugo; Padovani, Carlos Roberto; Trindade, Alceu Sergio; Machado, Wellington Monteiro

    2008-01-01

    This study evaluated the effect of implant-supported oral rehabilitation in the mandible on the electromyographic activity during mastication and swallowing in edentulous elderly individuals. Fifteen patients aged more than 60 years were evaluated, being 10 females and 5 males. All patients were edentulous, wore removable complete dentures on both dental arches, and had the mandibular dentures replaced by implant-supported prostheses. All patients were submitted to electromyographic evaluation of the masseter, superior orbicularis oris muscles, and the submental muscles, before surgery and 3, 6 and 18 months postoperatively, using foods of different textures. The results obtained at the different periods were analyzed statistically by Kruskal-Wallis non-parametric test. Statistical analysis showed that only the masseter muscle had a significant loss in electromyographic activity (p<0.001), with a tendency of similar response for the submental muscles. Moreover, there was an increase in the activity of the orbicularis oris muscle during rubber chewing after treatment, yet without statistically significant difference. Mandibular fixed implant-supported prostheses in elderly individuals revealed a decrease in electromyographic amplitude for the masseter muscles during swallowing, which may indicate adaptation to new conditions of stability provided by fixation of the complete denture in the mandibular arch. PMID:19089202

  19. Evaluation of non-conformities of hip prostheses made of titanium alloys and stainless steel

    International Nuclear Information System (INIS)

    Bezerra, Ewerton de Oliveira Teotonio; Nascimento, Jose Jeferson da Silva; Luna, Carlos Bruno Barreto; Morais, Crislene Rodrigues da Silva; Campos, Karla Valeria Miranda de

    2017-01-01

    A large number of metallic alloys has satisfactory behavior when used to manufacture implants for hip prostheses. However, they must be in conformity with standards, to ensure their quality for long periods without losing its functionality. Therefore, this paper aims to study the non-conformities in two hip prostheses, one of titanium and other stainless steel according to standards. The implants studied passed by X-ray diffraction (XRD), X-ray fluorescence, tensile test and optical microscopy (OM). Specimens for the tensile test were made according to ASTM E 8M, as well, MO samples passed by metallographic procedure. The results evidenced that some chemical compositions showed in relation to the standards. The XRD analysis showed peaks of austenite and absence of ferrite for the stainless steel, while the titanium alloy presents an alpha phase (HCP) more significant than the beta phase (BCC). The stainless steel alloys and titanium have yield strength and tensile strength that meet the standards. On the other hand, the elastic modulus of the titanium alloy and stainless steel, comes to be ten times greater than the human bone. Therefore, the high modulus of elasticity of the alloys, favors bone resorption problems. The stainless steel microstructure is typical of an austenitic matrix, while the titanium alloy presents α + β microstructure. (author)

  20. Characterization of In-Body to On-Body Wireless Radio Frequency Link for Upper Limb Prostheses.

    Directory of Open Access Journals (Sweden)

    Antonietta Stango

    Full Text Available Wireless implanted devices can be used to interface patients with disabilities with the aim of restoring impaired motor functions. Implanted devices that record and transmit electromyographic (EMG signals have been applied for the control of active prostheses. This simulation study investigates the propagation losses and the absorption rate of a wireless radio frequency link for in-to-on body communication in the medical implant communication service (MICS frequency band to control myoelectric upper limb prostheses. The implanted antenna is selected and a suitable external antenna is designed. The characterization of both antennas is done by numerical simulations. A heterogeneous 3D body model and a 3D electromagnetic solver have been used to model the path loss and to characterize the specific absorption rate (SAR. The path loss parameters were extracted and the SAR was characterized, verifying the compliance with the guideline limits. The path loss model has been also used for a preliminary link budget analysis to determine the feasibility of such system compliant with the IEEE 802.15.6 standard. The resulting link margin of 11 dB confirms the feasibility of the system proposed.

  1. Preliminary study of acoustic analysis for evaluating speech-aid oral prostheses: Characteristic dips in octave spectrum for comparison of nasality.

    Science.gov (United States)

    Chang, Yen-Liang; Hung, Chao-Ho; Chen, Po-Yueh; Chen, Wei-Chang; Hung, Shih-Han

    2015-10-01

    Acoustic analysis is often used in speech evaluation but seldom for the evaluation of oral prostheses designed for reconstruction of surgical defect. This study aimed to introduce the application of acoustic analysis for patients with velopharyngeal insufficiency (VPI) due to oral surgery and rehabilitated with oral speech-aid prostheses. The pre- and postprosthetic rehabilitation acoustic features of sustained vowel sounds from two patients with VPI were analyzed and compared with the acoustic analysis software Praat. There were significant differences in the octave spectrum of sustained vowel speech sound between the pre- and postprosthetic rehabilitation. Acoustic measurements of sustained vowels for patients before and after prosthetic treatment showed no significant differences for all parameters of fundamental frequency, jitter, shimmer, noise-to-harmonics ratio, formant frequency, F1 bandwidth, and band energy difference. The decrease in objective nasality perceptions correlated very well with the decrease in dips of the spectra for the male patient with a higher speech bulb height. Acoustic analysis may be a potential technique for evaluating the functions of oral speech-aid prostheses, which eliminates dysfunctions due to the surgical defect and contributes to a high percentage of intelligible speech. Octave spectrum analysis may also be a valuable tool for detecting changes in nasality characteristics of the voice during prosthetic treatment of VPI. Copyright © 2014. Published by Elsevier B.V.

  2. Aging of monolithic zirconia dental prostheses: Protocol for a 5-year prospective clinical study using ex vivo analyses.

    Science.gov (United States)

    Koenig, Vinciane; Wulfman, Claudine P; Derbanne, Mathieu A; Dupont, Nathalie M; Le Goff, Stéphane O; Tang, Mie-Leng; Seidel, Laurence; Dewael, Thibaut Y; Vanheusden, Alain J; Mainjot, Amélie K

    2016-12-15

    Recent introduction of computer-aided design/computer-aided manufacturing (CAD/CAM) monolithic zirconia dental prostheses raises the issue of material low thermal degradation (LTD), a well-known problem with zirconia hip prostheses. This phenomenon could be accentuated by masticatory mechanical stress. Until now zirconia LTD process has only been studied in vitro . This work introduces an original protocol to evaluate LTD process of monolithic zirconia prostheses in the oral environment and to study their general clinical behavior, notably in terms of wear. 101 posterior monolithic zirconia tooth elements (molars and premolars) are included in a 5-year prospective clinical trial. On each element, several areas between 1 and 2 mm 2 (6 on molars, 4 on premolars) are determined on restoration surface: areas submitted or non-submitted to mastication mechanical stress, glazed or non-glazed. Before prosthesis placement, ex vivo analyses regarding LTD and wear are performed using Raman spectroscopy, SEM imagery and 3D laser profilometry. After placement, restorations are clinically evaluated following criteria of the World Dental Federation (FDI), complemented by the analysis of fracture clinical risk factors. Two independent examiners perform the evaluations. Clinical evaluation and ex vivo analyses are carried out after 6 months and then each year for up to 5 years. For clinicians and patients, the results of this trial will justify the use of monolithic zirconia restorations in dental practice. For researchers, the originality of a clinical study including ex vivo analyses of material aging will provide important data regarding zirconia properties.Trial registration: ClinicalTrials.gov Identifier: NCT02150226.

  3. Integration of the Residual Limb with Prostheses via Direct Skin-Bone-Peripheral Nerve Interface

    Science.gov (United States)

    2017-10-01

    AWARD NUMBER: W81XWH-16-1-0791 TITLE: Integration of the Residual Limb with Prostheses via Direct Skin- Bone-Peripheral Nerve Interface...ABOVE ADDRESS. 1. REPORT DATE October 2017 2. REPORT TYPE Annual 3. DATES COVERED 30 Sep 2016 - 29 Sep 2017 4. TITLE AND SUBTITLE Integration of the...translational study to develop Skin and Bone Integrated Pylon with Peripheral Neural Interface (SBIP-PNI) directly attached to the residuum and the

  4. Sport prostheses and prosthetic adaptations for the upper and lower limb amputees : an overview of peer reviewed literature

    NARCIS (Netherlands)

    Bragaru, Mihai; Dekker, Rienk; Geertzen, Jan H. B.

    Background: Sport prostheses are used by both upper- and lower-limb amputees while participating in sports and other physical activities. Although the number of these devices has increased over the past decade, no overview of the peer reviewed literature describing them has been published

  5. Surface characterization of polymers used in fabrication of interim prostheses after treatment with photopolymerized glaze

    International Nuclear Information System (INIS)

    Santos, Daniela Micheline dos; Commar, Betina Chiarelo; Rocha Bonatto, Liliane da; Freitas da Silva, Emily Vivianne; Sônego, Mariana Vilela; Rangel, Elidiane Cipriano; Pesqueira, Aldieris Alves; Goiato, Marcelo Coelho

    2017-01-01

    The material used for interim prostheses fabrication must present excellent physical properties for greater longevity in the face of environmental conditions, which can occur in the oral cavity. The purpose of this study was to evaluate the effect of a photopolymerized glaze on the physical and mechanical properties of polymers used for the fabrication of interim prostheses, before and after thermocycling and immersion in staining solutions. One hundred samples of composite and acrylic resins were fabricated: Dencor chemically activated acrylic resin (CAAR) (n = 20) and heat-polymerized acrylic resin (HPAR) (n = 20), Charisma (n = 20), Structur (n = 20), and Protemp (n = 20). A mechanical polishing was performed on half of the samples, and a chemical polishing was performed on the remaining samples. Subsequently, all samples were submitted to thermocycling and immersion in coffee staining solution for 21 days. Analysis of color and microhardness, as well as atomic force microscopy (AFM), scanning electron microscopy (SEM), and energy dispersive x-ray spectrometry (EDS) were performed. The data were submitted to repeated-measures analysis of variance (ANOVA), followed by the Tukey test (α = 0.05) and the Student t-test (α = 0.05). It was verified that the glaze decreased the chromatic alteration values, and increased the microhardness values of the samples, with the exception of the Charisma resin. The samples that did not receive chemical polishing had the greatest number of surface irregularities. This study concluded that the groups with glaze presented less color alteration. In addition, Charisma and Structur resins exhibited the greatest chromatic stability. As to the microhardness, the values were greater when the samples were treated with the glaze, with the exception of the Charisma group. - Highlights: • Polymers used in fabrication of interim prostheses were analyzed. • The influence of a chemical polishing on these polymers was analyzed.

  6. Implant loading protocols for edentulous patients with fixed prostheses: a systematic review and meta-analysis.

    Science.gov (United States)

    Papaspyridakos, Panos; Chen, Chun-Jung; Chuang, Sung-Kiang; Weber, Hans-Peter

    2014-01-01

    To report on the effect of immediate implant loading with fixed prostheses compared to early and conventional loading on implant and prosthesis survival, failure, and complications. An electronic and manual search was conducted to identify randomized controlled clinical trials (RCTs) as well as prospective and retrospective studies involving rough surface implants and implant fixed complete dental prostheses for edentulous patients. The 62 studies that fulfilled the inclusion criteria featured 4 RCTs, 2 prospective case-control studies, 34 prospective cohort studies, and 22 retrospective cohort studies. These studies yielded data from 2,695 patients (2,757 edentulous arches) with 13,653 implants. Studies were grouped according to the loading protocol applied; 45 studies reported on immediate loading, 8 on early loading, and 11 on conventional loading. For the immediate loading protocol with flap surgery, the implant and prosthesis survival rates ranged from 90.1% to 100% and 93.75% to 100%, respectively (range of follow-up, 1 to 10 years). When immediate loading was combined with guided flapless implant placement, the implant survival rates ranged from 90% to 99.4%. For the early loading protocol, the implant and prosthesis survival rates ranged from 94.74% to 100% and 93.75% to 100%, respectively (range of follow-up, 1 to 10 years). For the conventional loading protocol, the implant and prosthesis survival rates ranged from 94.95% to 100% and 87.5% to 100%, respectively (range of follow-up, 2 to 15 years). No difference was identified between maxilla and mandible. When selecting cases carefully and using dental implants with a rough surface, immediate loading with fixed prostheses in edentulous patients results in similar implant and prosthesis survival and failure rates as early and conventional loading. For immediate loading, most of the studies recommended a minimal insertion torque of 30 Ncm. The estimated 1-year implant survival was above 99% with all three

  7. Surface characterization of polymers used in fabrication of interim prostheses after treatment with photopolymerized glaze

    Energy Technology Data Exchange (ETDEWEB)

    Santos, Daniela Micheline dos, E-mail: danielamicheline@foa.unesp.br [Department of Dental Materials and Prosthodontics, Aracatuba Dental School, Univ Estadual Paulista (UNESP), José Bonifácio St., 1193, Aracatuba, São Paulo 16015-050 (Brazil); Commar, Betina Chiarelo; Rocha Bonatto, Liliane da; Freitas da Silva, Emily Vivianne; Sônego, Mariana Vilela [Department of Dental Materials and Prosthodontics, Aracatuba Dental School, Univ Estadual Paulista (UNESP), José Bonifácio St., 1193, Aracatuba, São Paulo 16015-050 (Brazil); Rangel, Elidiane Cipriano [Technological Plasma Laboratory (LaPTec), Experimental Campus of Sorocaba, Univ Estadual Paulista (UNESP), Tres de Março Av., 511, Sorocaba, Sao Paulo, 18087-180 (Brazil); Pesqueira, Aldieris Alves; Goiato, Marcelo Coelho [Department of Dental Materials and Prosthodontics, Aracatuba Dental School, Univ Estadual Paulista (UNESP), José Bonifácio St., 1193, Aracatuba, São Paulo 16015-050 (Brazil)

    2017-02-01

    The material used for interim prostheses fabrication must present excellent physical properties for greater longevity in the face of environmental conditions, which can occur in the oral cavity. The purpose of this study was to evaluate the effect of a photopolymerized glaze on the physical and mechanical properties of polymers used for the fabrication of interim prostheses, before and after thermocycling and immersion in staining solutions. One hundred samples of composite and acrylic resins were fabricated: Dencor chemically activated acrylic resin (CAAR) (n = 20) and heat-polymerized acrylic resin (HPAR) (n = 20), Charisma (n = 20), Structur (n = 20), and Protemp (n = 20). A mechanical polishing was performed on half of the samples, and a chemical polishing was performed on the remaining samples. Subsequently, all samples were submitted to thermocycling and immersion in coffee staining solution for 21 days. Analysis of color and microhardness, as well as atomic force microscopy (AFM), scanning electron microscopy (SEM), and energy dispersive x-ray spectrometry (EDS) were performed. The data were submitted to repeated-measures analysis of variance (ANOVA), followed by the Tukey test (α = 0.05) and the Student t-test (α = 0.05). It was verified that the glaze decreased the chromatic alteration values, and increased the microhardness values of the samples, with the exception of the Charisma resin. The samples that did not receive chemical polishing had the greatest number of surface irregularities. This study concluded that the groups with glaze presented less color alteration. In addition, Charisma and Structur resins exhibited the greatest chromatic stability. As to the microhardness, the values were greater when the samples were treated with the glaze, with the exception of the Charisma group. - Highlights: • Polymers used in fabrication of interim prostheses were analyzed. • The influence of a chemical polishing on these polymers was analyzed.

  8. Platelet thrombosis in cardiac-valve prostheses

    International Nuclear Information System (INIS)

    Dewanjee, M.K.

    1989-01-01

    The contribution of platelets and clotting factors in thrombosis on cardiovascular prostheses had been quantified with several tracers. Thrombus formation in vivo could be measured semiquantitatively in animal models and patients with indium-111, Technetium-99m labeled platelets, iodine-123, iodine-131 labeled fibrinogen, and In-111 and Tc-99m labeled antibody to the fibrinogen-receptor on the platelet- membrane, or fibrin. The early studies demonstrated that certain platelet-inhibitors, e.g. sulfinpyrazone, aspirin or aspirin- persantine increased platelet survival time with mechanical valves implanted in the baboon model and patients. Thrombus localization by imaging is possible for large thrombus on thrombogenic surface of prosthesis in the acute phase. The majority of thrombus was found in the sewing ring (Dacron) in the acute phase in both the mechanical and tissue valves. The amount of retained thrombus in both mechanical and tissue valves in our one-day study in the dog model was similar (< 1% if injected In-111 platelets = 5 billion platelets). As the fibrous ingrowth covered the sewing ring, the thrombus formation decreased significantly. Only a small amount of thrombus was found on the leaflets at one month in both the dog and calf models. 38 refs., 9 figs., 5 tabs

  9. Platelet thrombosis in cardiac-valve prostheses

    Energy Technology Data Exchange (ETDEWEB)

    Dewanjee, M.K.

    1989-01-01

    The contribution of platelets and clotting factors in thrombosis on cardiovascular prostheses had been quantified with several tracers. Thrombus formation in vivo could be measured semiquantitatively in animal models and patients with indium-111, Technetium-99m labeled platelets, iodine-123, iodine-131 labeled fibrinogen, and In-111 and Tc-99m labeled antibody to the fibrinogen-receptor on the platelet- membrane, or fibrin. The early studies demonstrated that certain platelet-inhibitors, e.g. sulfinpyrazone, aspirin or aspirin- persantine increased platelet survival time with mechanical valves implanted in the baboon model and patients. Thrombus localization by imaging is possible for large thrombus on thrombogenic surface of prosthesis in the acute phase. The majority of thrombus was found in the sewing ring (Dacron) in the acute phase in both the mechanical and tissue valves. The amount of retained thrombus in both mechanical and tissue valves in our one-day study in the dog model was similar (< 1% if injected In-111 platelets = 5 billion platelets). As the fibrous ingrowth covered the sewing ring, the thrombus formation decreased significantly. Only a small amount of thrombus was found on the leaflets at one month in both the dog and calf models. 38 refs., 9 figs., 5 tabs.

  10. Clinical experiences of implant-supported prostheses with laser-welded titanium frameworks in the partially edentulous jaw: a 5-year follow-up study.

    Science.gov (United States)

    Ortorp, A; Jemt, T

    1999-01-01

    Titanium frameworks have been used in the endentulous implant patient for the last 10 years. However, knowledge of titanium frameworks for the partially dentate patient is limited. To report the 5-year clinical performance of implant-supported prostheses with laser-welded titanium frameworks in the partially edentulous jaw. A consecutive group of 383 partially edentulous patients were, on a routine basis, provided with fixed partial prostheses supported by Brånemark implants in the mandible or maxilla. Besides conventional frameworks in cast gold alloy, 58 patients were provided with titanium frameworks with three different veneering techniques, and clinical and radiographic 5-year data were collected for this group. The overall cumulative survival rate was 95.6% for titanium-framework prostheses and 93.6% for implants. Average bone loss during the follow-up period was 0.4 mm. The most common complications were minor veneering fractures. Loose and fractured implant screw components were fewer than 2%. An observation was that patients on medications for cardiovascular problems may lose more implants than others (p laser-welded titanium frameworks was similar to that reported for conventional cast frames in partially edentulous jaws. Low-fusing porcelain veneers also showed clinical performance comparable to that reported for conventional porcelain-fused-to-metal techniques.

  11. Evaluation of total alloplastic temporo-mandibular joint replacement with two different types of prostheses: A three-year prospective study.

    Science.gov (United States)

    Gonzalez-Perez, L-M; Gonzalez-Perez-Somarriba, B; Centeno, G; Vallellano, C; Montes-Carmona, J-F

    2016-11-01

    Temporo-Mandibular Joint (TMJ) replacement has been used clinically for years. The objective of this study was to evaluate outcomes achieved in patients with two different categories of TMJ prostheses. All patients who had a TMJ replacement (TMJR) implanted during the study period from 2006 through 2012 were included in this 3-year prospective study. All procedures were performed using the Biomet Microfixation TMJ Replacement System, and all involved replacing both the skull base component (glenoid fossa) and the mandibular condyle. Fifty-seven patients (38 females and 19 males), involving 75 TMJs with severe disease requiring reconstruction (39 unilateral, 18 bilateral) were operated on consecutively, and 68 stock prostheses and 7 custom-made prostheses were implanted. The mean age at surgery was 52.6±11.5 years in the stock group and 51.8±11.7 years in the custom-made group. In the stock group, after three years of TMJR, results showed a reduction in pain intensity from 6.4±1.4 to 1.6±1.2 (p<0.001), and an improvement in jaw opening from 2.7±0.9 cm to 4.2±0.7 cm (p<0.001). In the custom-made group, after three years of TMJR, results showed a reduction in pain intensity from 6.0±1.6 to 2.2±0.4 (p<0.001), and an improvement in jaw opening from 1.5±0.5 cm to 4.3±0.6 cm (p<0.001). No statistically significant differences between two groups were detected. The results of this three-year prospective study support the surgical placement of TMJ prostheses (stock prosthetic, and custom-made systems), and show that the approach is efficacious and safe, reduces pain, and improves maximum mouth opening movement, with few complications. As such, TMJR represents a viable technique and a stable long-term solution for cranio-mandibular reconstruction in patients with irreversible end-stage TMJ disease. Comparing stock and custom-made groups, no statistically significant differences were detected with respect to pain intensity reduction and maximum mouth opening

  12. Experimental substantiation of a method of early diagnosis of infectivity of vascular prostheses with the help of 99mTc-leukocytes

    International Nuclear Information System (INIS)

    Zatevakhin, I.I.; Malov, G.A.; Govorunov, G.V.; Dobronravov, D.S.; Makhmudov, S.Ya.; Komrakov, V.E.

    1988-01-01

    Experiments on 9 dogs were staged for a study of a method of early diagnosis of infectivity of vascular prostheses of the abdominal aorta with the help of 99m Tc-labeled leukocytes. A sterile synthetic vascular prosthesis was used for prosthetics of the abdominal aorta in the 1st control group of animals, a prosthesis, previously infected with St. aureus, was used in the 2nd group, a sterile prosthesis with its subsequent infecting by i.v. injection of St. aureus was used in the 3rd group. The tolre of antibiotic therapy in infectivity of vascular prostheses was studied on the animals of the 3rd group. A radionuclide study with autologous 99m Tc-labeled leukocytes was conducted using the Deina-2 camera (Picker). Visualization of the prostheses was unobserved in the 1st control group; in the 2nd group the accumulation of 99m Tc-leucocytes in the zone of the prosthesis and its vizualization on the 4th-5th min. were noted; in the 3rd group the prothesis was visualized on the 10th-15th min. After antibiotic therapy in the 3rd group visualization of the prothesis was undetectable. The proposed method permitted visualization of a zone of infection in the early postoperative period, observation of the time course of infection development, and assessment of the efficacy of antibiotic therapy

  13. A Meta-Analysis Examining Differences in Short-Term Outcomes Between Sutureless and Conventional Aortic Valve Prostheses.

    Science.gov (United States)

    Hurley, Eoghan T; O'Sullivan, Katie E; Segurado, Ricardo; Hurley, John P

    2015-01-01

    Sutureless aortic valve prostheses are anchored by radial force in a mechanism similar to that of transcatheter aortic valve implantation. Transcatheter aortic valve implantation is associated with an increased permanent pacemaker (PPM) requirement in a significant proportion of patients. We undertook a meta-analysis to examine the incidence of PPM insertion associated with sutureless compared with conventional surgical aortic valve replacement. A systematic review was conducted in accordance with the Prisma guidelines. All searches were performed on August 10, 2014. Studies between 2007 and 2014 were included in the search. A total of 832 patients were included in the sutureless group and 3,740 in the conventional group. Aortic cross-clamp (39.8 vs 62.4 minutes; P < 0.001) and cardiopulmonary bypass (64.9 vs 86.7 minutes; P = 0.002) times were shorter in the sutureless group. Permanent pacemaker implantation rate was higher in the sutureless cohort (9.1% vs 2.4%; P = 0.025). Sutureless aortic valve prostheses are associated with significantly shorter cardiopulmonary bypass and aortic cross-clamp times and a higher incidence of PPM insertion than conventional. Further investigation of the prognostic significance is required.

  14. Survival of anterior cantilevered all-ceramic resin-bonded fixed dental prostheses made from zirconia ceramic.

    Science.gov (United States)

    Sasse, Martin; Kern, Matthias

    2014-06-01

    This study evaluated the clinical outcome of all-ceramic resin-bonded fixed dental prostheses (RBFDPs) with a cantilevered single-retainer design made from zirconia ceramic. Forty-two anterior RBFDPs with a cantilevered single-retainer design were made from yttrium oxide-stabilized zirconium oxide ceramic. RBFDPs were inserted using Panavia 21 TC as luting agent after air-abrasion of the ceramic bonding surface. During a mean observation time of 61.8 months two debondings occurred. Both RBFDPs were rebonded using Panavia 21 TC and are still in function. A caries lesion was detected at one abutment tooth during recall and was treated with a composite filling. Therefore, the overall six-year failure-free rate according to Kaplan-Meier was 91.1%. If only debonding was defined as failure the survival rate increased to 95.2%. Since all RBFDPs are still in function the overall survival rate was 100% after six years. Cantilevered zirconia ceramic RBFDPs showed promising results within the observation period. Single-retainer resin-bonded fixed dental prostheses made from zirconia ceramic show very good mid-term clinical survival rates. They should therefore be considered as a viable treatment alternative for the replacement of single missing anterior teeth especially as compared to an implant therapy. Copyright © 2014 Elsevier Ltd. All rights reserved.

  15. Electromyographic evaluation of mastication and swallowing in elderly individuals with mandibular fixed implant-supported prostheses

    Directory of Open Access Journals (Sweden)

    Giédre Berretin-Felix

    2008-04-01

    Full Text Available This study evaluated the effect of implant-supported oral rehabilitation in the mandible on the electromyographic activity during mastication and swallowing in edentulous elderly individuals. Fifteen patients aged more than 60 years were evaluated, being 10 females and 5 males. All patients were edentulous, wore removable complete dentures on both dental arches, and had the mandibular dentures replaced by implant-supported prostheses. All patients were submitted to electromyographic evaluation of the masseter, superior orbicularis oris muscles, and the submental muscles, before surgery and 3, 6 and 18 months postoperatively, using foods of different textures. The results obtained at the different periods were analyzed statistically by Kruskal-Wallis non-parametric test. Statistical analysis showed that only the masseter muscle had a significant loss in electromyographic activity (p<0.001, with a tendency of similar response for the submental muscles. Moreover, there was an increase in the activity of the orbicularis oris muscle during rubber chewing after treatment, yet without statistically significant difference. Mandibular fixed implant-supported prostheses in elderly individuals revealed a decrease in electromyographic amplitude for the masseter muscles during swallowing, which may indicate adaptation to new conditions of stability provided by fixation of the complete denture in the mandibular arch.

  16. Gamma Ray Sterilization of Starr-Edwards Heart Valve Prostheses

    Energy Technology Data Exchange (ETDEWEB)

    Gibbons, J. R. P.; Alladine, M. F. [London Chest Hospital, London (United Kingdom)

    1967-09-15

    Starr-Edwards valves have normally been sterilized by exposure to ethylene oxide or by autoclaving. Patients having a prosthetic valve replacement are known to have a higher incidence of endocarditis in comparison with patients in which no prosthesis has been used. Ethylene oxide will only sterilize the surface of the valve and autoclaving has caused distortion of the polytetrafluorethylene ring. Work has been done on the effect of gamma radiation on the components of these valve prostheses and is given in detail. The bacteriological efficiency, at a total absorbed dose of 2. 5 Mrad, has been established. Thirty valves treated by this method have now been inserted and twelve patients have been examined post-operatively for a period of one to two years. All valves are working normally and there has been no evidence of blood-borne infection or malfunction of the valve. (author)

  17. Radiological follow-up of uncemented knee prostheses. Preliminary study

    International Nuclear Information System (INIS)

    Martin Hervas, C.; Gomez Barrena, E.; Marquez Moreno, I.; Calle Yuste, F.; Ordonez Parra, J.M.

    1993-01-01

    The preliminary results of a prospective study of 40 uncemented total knee prostheses (TKP) are presented following a radiological protocol with fluoroscopic control and follow-up of over 2 years. The prosthesis-bone interface and the components alignment were assessed. Several radiological signs were studied to assess this interface with respect to the fixing of the component, but they showed little clinical correlation. Statistical significance (p<0.05, chisquare) was found only in the observation of sclerosis in areas of support for the tibital tray as a reaction of the bone. This radiological follow-up is of interest to determine the evolution of the interface and position of the implant to prevent complications (especially loosening) in patients, particularly those under 60 years old, who represent the group that can most benefit from prosthetic systems with uncemented anchorage because of their life expectation and level of activity. Author

  18. Myoelectric signal processing for control of powered limb prostheses.

    Science.gov (United States)

    Parker, P; Englehart, K; Hudgins, B

    2006-12-01

    Progress in myoelectric control technology has over the years been incremental, due in part to the alternating focus of the R&D between control methodology and device hardware. The technology has over the past 50 years or so moved from single muscle control of a single prosthesis function to muscle group activity control of multifunction prostheses. Central to these changes have been developments in the means of extracting information from the myoelectric signal. This paper gives an overview of the myoelectric signal processing challenge, a brief look at the challenge from an historical perspective, the state-of-the-art in myoelectric signal processing for prosthesis control, and an indication of where this field is heading. The paper demonstrates that considerable progress has been made in providing clients with useful and reliable myoelectric communication channels, and that exciting work and developments are on the horizon.

  19. Clinical and radiological evolution of Intervened patients of total arthroplasty of hip with prostheses of resuperficialization metal-metal - Preliminary report

    International Nuclear Information System (INIS)

    Galvan Villamarin, Fernando; Bernal Torres, Fabio A; Paez, Jose Mauricio and others

    2006-01-01

    The articular degeneration of the hip in young patients requires including therapeutical alternatives for the management of this population. The resurfacing prostheses with metal-metal surfaces is an alternative for this type of patients. Reports with short and medium follow up are very promising, besides the different studies of laboratory that bear, the theoretical bases for their success. In this descriptive study, observational cases series type is described the radiological and clinical evolution of patients intervened of total arthroplasty of hip with resurfacing prostheses metal-metal in the hospital el Tunal of Bogota. The results of 31 hips are presented (27 patients) with an age average of 50 years old and a medium follow up of 16 months, with a good post surgical functional result with a median of 96 in the Harris Scores. The complications presented in the patient series are described and their relation with the different factors analyzed

  20. Purely transvaginal/perineal management of complications from commercial prolapse kits using a new prostheses/grafts complication classification system.

    Science.gov (United States)

    Firoozi, Farzeen; Ingber, Michael S; Moore, Courtenay K; Vasavada, Sandip P; Rackley, Raymond R; Goldman, Howard B

    2012-05-01

    Commercial prolapse mesh kits are increasingly used in the management of pelvic organ prolapse. We present our experience with the transvaginal/perineal management of synthetic mesh related complications from prolapse kits. In addition, we used the new ICS/IUGA (International Continence Society/International Urogynecological Association) prostheses/grafts complication classification system to report on our contemporary series. A retrospective chart review of all patients who underwent surgical removal of transvaginal mesh for mesh related complications after prolapse kit use from November 2006 to April 2010 at 1 institution was performed. We report our contemporary series of mesh complications using the new ICS/IUGA prostheses/grafts complication classification system. Postoperative pain, degree of improvement and presence of continued symptoms were reported by patients at last followup. A total of 23 patients underwent transvaginal removal of mesh during the study period. Mean patient age was 61 years. Median period of latency to mesh related complication was 10 months (range 1 to 27). Indications for mesh removal included vaginal/pelvic pain (39%), dyspareunia (39%), vaginal mesh extrusion/exposure (26%), urinary incontinence (35%), recurrent pelvic organ prolapse (22%), bladder mesh perforation with recurrent urinary tract infection (22%), rectal mesh perforation (4%), ureteral perforation injury (4%), retained foreign body (surgical sponge) in the bladder (4%) and vesicovaginal fistula (9%), with most patients citing more than 1 reason. Although technically difficult in some cases, purely transvaginal mesh excision appears to be safe with resolution of almost all presenting symptoms. Although slightly cumbersome, the new ICS/IUGA prostheses/graft complication classification system can be used to report and more accurately characterize mesh complications. Copyright © 2012 American Urological Association Education and Research, Inc. Published by Elsevier Inc

  1. [Communication prostheses and behavioral alignment in hospital leaflets].

    Science.gov (United States)

    Vasconcellos-Silva, Paulo Roberto; Rivera, Francisco Javier Uribe; Rozemberg, Brani

    2003-08-01

    Review was made of publications that describe experience with printed material distributed to the lay public in hospital institutions. From the 146 leaflets examined, those aimed at professionals or disabled people, thus leaving 75 papers that illustrate the present pattern for the rationality behind the production, use and evaluation of this type of resource. In a general manner, such leaflets invest in the power of "ideal printed information" to align behavior with the hospital's biomedical agenda. The underlying rationality that permeates them perceives the "perfect information package" as one that efficiently describes its technical content for the purpose of unidirectional persuasion, is up-to-date in relation to readability scales and embellished by graphic design, and emphasizes the priorities defined by the professionals. Such "communication prostheses" should be capable of electronic validation by means of software suitable for proportioning the "doses" to the subject matter. Information as a drug, cognitivism, the lack of research on message reception and the need for communicative action for the deconstruction of systems of closed thinking within the hospital environment have been discussed.

  2. 500 penile prostheses implanted by a surgeon in Italy in the last 30 years

    Directory of Open Access Journals (Sweden)

    Diego Pozza

    2015-09-01

    Full Text Available Objectives: The aim of our study was to report our experience with patients affected by Erectile Dysfunction (ED and undergoing penile prosthetic implantation (PPI in a single center by a single surgeon. Material and Methods: We retrospectively evaluated the clinical outcome of 500 patients (mean age: 51.5 years, range: 20-86 years affected by ED and referred to our private andrological center from January 1984 to December 2013 who underwent penile prosthesis implantation, including the reported level of patient satisfaction. Results: 182 silicone, 180 malleable, 18 monocomponent hydraulic and 120 multicomponents hydraulic prostheses were implanted by the same experienced surgeon. All patients were hospitalized for the procedure. All patients were evaluated immediately, 1 month (496 patients and, for the great majority, every year after implantation. One hundred twenty five patients were lost to follow-up. Twenty two patients underwent revision surgery for complications in the postoperative period. The most serious postoperative complications were mechanical problems (45 patients, 9.0% and infection (15 patients, 3%. Forty two (8.4% prostheses were explanted. Overall, 80% (400/500 of patients were able to have sexual intercourse and were fully satisfied with the results. Conclusions: In our experience prosthetic surgery should be considered a good solution for men affected by ED and not responsive to other therapeutic solutions. Prosthetic surgery can be performed not only in large public hospitals but also in smaller private facilities.

  3. [PVD-silicoating before cementation of zirconia-based knee prostheses effects better cement adhesion and lower aseptic loosening rates].

    Science.gov (United States)

    Marx, R; Faramarzi, R; Oberbach, T; Begand, S; Grätz, N; Wirtz, D C

    2012-02-01

    CoCrMo alloys are contraindicated for allergy patients. For these patients, cemented or uncemented prostheses made of titanium alloy are indicated. Uncemented prostheses, however, have low primary retention, particularly the tibial components of knee joint prostheses because of the lack of a positive locking. Therefore, for knee replacement cemented CoCrMo prostheses may be suitable also for allergy sufferers if these are masked by ZrN or TiNbN layers. Alternatively the CoCrMo alloy may be replaced by high-strength oxide ceramics. For adhesion of bone cement to the ceramic surface, however, only inefficient mechanical retention spots are exposed as compared with a metal surface. Undercuts generated by corundum blasting, although highly efficient on a CoCrMo surface, are not such efficient centres on a ceramic surface due to its brittleness. Therefore, the mechanical component of retention is significantly reduced. When specific adhesion between bone cement and surface does not exist due to physical and chemical forces, the hydrolytic stability will be insufficient. Micromotions are promoted and early aseptic loosening is predictable. Silicoating of the ceramic surface will allow specific adhesion and can result in better hydrolytic stability of bonding. In order to evaluate the effectiveness of silicoating the bond strengths of blasted (mean size of corundum grains 50 µm) and silicate layered alumina-toughened zirconia (ATZ) surfaces were compared with "as fired" surfaces by utilising TiAlV probes (diameter 6 mm) for traction-adhesive strength testing. Samples machined out of CoCrMo alloy were utilised for reference. After preparing the samples for traction-adhesive strength testing (sequence: substrate, silicate and silane, protective lacquer [PolyMA], bone cement, TiAlV probe) they were aged up to 360 days at 37 °C in Ringer's solution. The bond strengths observed for all ageing intervals were well above 20 MPa and much higher and more hydrolytically

  4. Immediate prostheses on one-piece trans-mucosal implants in flapless surgical procedures Case Series Report. Part I: full arch rehabilitations

    Directory of Open Access Journals (Sweden)

    Aris Petros Tripodakis

    2012-06-01

    Full Text Available Aim: The aim of the present case series report is to illustrate a clinical technique and present the application of onepiece transmucosal implants in flapless surgical procedures, supporting full arch immediate prostheses. Materials and methods: A total of 294 implants (Xive TG, Friadent, Germany have been used to support full arch immediate prostheses, over the last six years and have been in function for at least one year. The surgical placement of five or more implants per case involved immediate extraction and intrasocket flapless placement, combined with minimal flap elevation in the areas of healed extraction sites (43 mandibular and 7 maxillary arches. In all cases immediate provisionalization followed. Detailed three-dimensional cone-beam localized volumetric tomography preceeded the surgical procedures. The delivery of the final ceramo-metal prostheses was accomplished within a 20 day period. Materials and methods: Results Six implants failed to osseointegrate. All other implants are still successfully bearing the final prosthesis for the time that they have been followed. Soft tissue reaction was favorable from both the biologic and esthetic point of view. Conclusion: The flapless placement of one piece implants into edentulous healed sites is a predictable procedure in the presence of abundance of supporting bone as confirmed by 3-D imaging. On the other hand, immediate extraction placement of one piece implants allows the engagement of sound bone located deeper into the socket and provides adequate mechanical support of the soft tissue architecture that is preserved predictably. In all cases the prosthetic procedures are accomplished without disturbing the hardsoft tissue interface as the abutment-prosthesis interface is coronally elevated by the virtual design of the implant.

  5. Marginal and Internal Fit of Cobalt-Chromium Fixed Dental Prostheses Generated from Digital and Conventional Impressions

    OpenAIRE

    Svanborg, Per; Skjerven, Henrik; Carlsson, Pablo; Eliasson, Alf; Karlsson, Stig; Örtorp, Anders

    2014-01-01

    Objectives. Digital impressions are increasingly used and have the potential to avoid the problem of inaccurate impressions. Only a few studies to verify the accuracy of digital impressions have been performed. The purpose of this study was to compare the marginal and internal fit of 3-unit tooth supported fixed dental prostheses (FDPs) fabricated from digital and conventional impressions. Methods. Ten FDPs were produced from digital impressions using the iTero system and 10 FDPs were produce...

  6. Early rehabilitation of facial defects using interim removable prostheses: A clinical case report

    Directory of Open Access Journals (Sweden)

    Vivekanandhan Ramkumar

    2013-01-01

    Full Text Available Surgical resection of neoplasms or malformations of the face may result in defects that are not amenable to immediate surgical reconstruction. Such defects can have a severe adverse effect on patient perceptions of body image and self-esteem. In these cases, the use of an interim removable facial prosthesis can offer a rapid alternative treatment solution. The patient may then resume social interactions more comfortably while permitting easy access to the facial defect to observe tissue healing while awaiting definitive rehabilitation. This article presents a case report describing the use of interim nasal prostheses to provide rapid patient rehabilitation of facial defects.

  7. Comparison of patellofemoral outcomes after TKA using two prostheses with different patellofemoral design features.

    Science.gov (United States)

    Bae, Dae Kyung; Baek, Jong Hun; Yoon, Kyung Tack; Son, Hyuck Sung; Song, Sang Jun

    2017-12-01

    The purpose of the present study was to compare the clinical and radiographic results after TKA using two prostheses with different sagittal patellofemoral design features, including outcomes related to compatibility of the patellofemoral joint. The clinical and radiographic results of 81 patients (100 knees) who underwent TKA using the specific prosthesis (group A) were compared with those in a control group who underwent TKA using the other prosthesis (group B). The presence of anterior knee joint pain, patellar crepitation, and patellar clunk syndrome was also checked. The function score and maximum flexion angle at the last follow-up were slightly better in group A than those in group B (92.0 ± 2.3 vs. 90.6 ± 4.2) (133.6° ± 8.4° vs. 129.6° ± 11.4°). Anterior knee pain was observed in 6 knees and patellar crepitation in four knees in group A. In group B, these symptoms were observed in 22 knees and 18 knees, respectively. There was no patellar clunk syndrome in either group. The alignment was corrected with satisfactory positioning of components. The patellar height remained unchanged after TKA in the two groups. The differences between preoperative and postoperative patellar tilt angle and patellar translation were small. When comparing the clinical and radiographic results after TKA using two prostheses with different sagittal patellofemoral design features, TKA using the specific prosthesis provided satisfactory results with less clinical symptoms related to the patellofemoral kinematics with TKA using the other prosthesis. III.

  8. Survival and failure modes: platform-switching for internal and external hexagon cemented fixed dental prostheses.

    Science.gov (United States)

    Anchieta, Rodolfo B; Machado, Lucas S; Hirata, Ronaldo; Coelho, Paulo G; Bonfante, Estevam A

    2016-10-01

    This study evaluated the probability of survival (reliability) of platform-switched fixed dental prostheses (FDPs) cemented on different implant-abutment connection designs. Eighty-four-three-unit FDPs (molar pontic) were cemented on abutments connected to two implants of external or internal hexagon connection. Four groups (n = 21 each) were established: external hexagon connection and regular platform (ERC); external hexagon connection and switched platform (ESC); internal hexagon and regular platform (IRC); and internal hexagon and switched platform (ISC). Prostheses were subjected to step-stress accelerated life testing in water. Weibull curves and probability of survival for a mission of 100,000 cycles at 400 N (two-sided 90% CI) were calculated. The beta values of 0.22, 0.48, 0.50, and 1.25 for groups ERC, ESC, IRC, and ISC, respectively, indicated a limited role of fatigue in damage accumulation, except for group ISC. Survival decreased for both platform-switched groups (ESC: 74%, and ISC: 59%) compared with the regular matching platform counterparts (ERC: 95%, and IRC: 98%). Characteristic strength was higher only for ERC compared with ESC, but not different between internal connections. Failures chiefly involved the abutment screw. Platform switching decreased the probability of survival of FDPs on both external and internal connections. The absence in loss of characteristic strength observed in internal hexagon connections favor their use compared with platform-switched external hexagon connections. © 2016 Eur J Oral Sci.

  9. Influence of varus/valgus positioning of the Nanos® and Metha® short-stemmed prostheses on stress shielding of metaphyseal bone.

    Science.gov (United States)

    Brinkmann, V; Radetzki, F; Gutteck, N; Delank, S; Zeh, A

    2017-03-01

    The aim of this study was to analyze bone remodeling around the Nanos® (Smith & Nephew) and Metha® (Aesculap AG) implants as a function of varus/valgus stem positioning. In 75 patients with diagnosed coxarthrosis, either Nanos® (n= 51) or Metha® (n= 24) prostheses were implanted. Digital assessment of plain radiographs immediately, 97 days, and 381 days after THA showed no clinically-relevant migration, angulation, or change in offset and center of rotation. The DEXA scans showed significant BMD changes in Gruen zones 1 (-12.8%), 2 (-3.3%), 6 (+6.4%), and 7(-7.8%)(t-test). The pre/postoperative CCD for the Nanos® was 129°/ 135° and for the Metha® 131°/ 127°. Linear regression analysis showed no prediction for BMD by postoperative CCD or stem type. In conclusion, there was no clinically-relevant influence on proximal femur BMD according to varus/valgus implantation of the Nanos® or Metha® prostheses.

  10. Cancer risk among patients with finger and hand joint and temporo-mandibular joint prostheses in Denmark.

    Science.gov (United States)

    Fryzek, J P; Mellemkjaer, L; McLaughlin, J K; Blot, W J; Olsen, J H

    1999-05-31

    The use of artificial joint implants has risen greatly over the past years. However, few investigations of the cancer risk associated with implants have been performed. We investigated cancer risk in patients with finger and hand joint and temporo-mandibular (TMJ) joint implants. A nationwide cohort in Denmark of patients with finger and hand joint prostheses (n = 858) or TMJ implants (n = 389) was followed from January 1, 1977, to December 31, 1995, to evaluate any potential cancer risks subsequent to receiving these implants. Standardized incidence ratios (SIRs) for all cancers were 1.0 (95% CI = 0.8-1.2) for the finger and hand joint cohort and 1.1 (95% CI = 0.8-1.7) for the TMJ cohort. A significant risk for non-Hodgkin's lymphoma was found in the finger and hand joint cohort (SIR = 3.8, 95% CI = 1.5-7.8). When the finger and hand joint cohort was stratified by diagnosis of rheumatoid arthritis, the excess risk was seen only in the group with rheumatoid arthritis. This is consistent with past studies, which have found an association between rheumatoid arthritis and non-Hodgkin's lymphoma. Our results provide evidence that the cancer risk for patients with finger and hand joint prostheses and TMJ implants is similar to that for the general population.

  11. Microcomputer-based artificial vision support system for real-time image processing for camera-driven visual prostheses

    Science.gov (United States)

    Fink, Wolfgang; You, Cindy X.; Tarbell, Mark A.

    2010-01-01

    It is difficult to predict exactly what blind subjects with camera-driven visual prostheses (e.g., retinal implants) can perceive. Thus, it is prudent to offer them a wide variety of image processing filters and the capability to engage these filters repeatedly in any user-defined order to enhance their visual perception. To attain true portability, we employ a commercial off-the-shelf battery-powered general purpose Linux microprocessor platform to create the microcomputer-based artificial vision support system (μAVS2) for real-time image processing. Truly standalone, μAVS2 is smaller than a deck of playing cards, lightweight, fast, and equipped with USB, RS-232 and Ethernet interfaces. Image processing filters on μAVS2 operate in a user-defined linear sequential-loop fashion, resulting in vastly reduced memory and CPU requirements during execution. μAVS2 imports raw video frames from a USB or IP camera, performs image processing, and issues the processed data over an outbound Internet TCP/IP or RS-232 connection to the visual prosthesis system. Hence, μAVS2 affords users of current and future visual prostheses independent mobility and the capability to customize the visual perception generated. Additionally, μAVS2 can easily be reconfigured for other prosthetic systems. Testing of μAVS2 with actual retinal implant carriers is envisioned in the near future.

  12. Clinical study on the success of posterior monolithic zirconia crowns and fixed dental prostheses: preliminary report

    Directory of Open Access Journals (Sweden)

    Merve Bankoğlu Güngör

    2017-09-01

    Full Text Available Objective: The purpose of this report was to present preliminary clinical results regarding the success rates and technical outcomes of posterior monolithic zirconia single tooth crowns (STs and fixed dental prostheses (FDPs. Materials and Method: Thirty-four patients received 43 posterior monolithic zirconia restorations as single tooth crowns (STs and/or fixed dental prostheses (FDPs, which were fabricated using a CAD-CAM (Computer Aided Design - Computer Aided Manufacturing system. At baseline and every 6 months, the restorations were examined for survival and technical outcomes. Success of the restorations was defined as the restoration remaining in situ, with no need for removal or replacement at follow-up visits. Technical outcomes were evaluated with a modified version of the United States Public Health Services criteria. Survival of restorations was estimated by using the Kaplan-Meier survival analysis. For each restoration, duration of follow-up was calculated from the time of placement to the date of its first failure. Results: After a mean observation period of 18.6 ± 3.9 months (between 8-24 months, cumulative survival rates were 86.7% and 92.3% for STs and FDPs, respectively. Technical evaluation revealed good marginal adaptation and crown contours; however, modifications were needed for shade and occlusion of restorations. Conclusion: These preliminary results revealed high survival rate and generally successful technical outcomes for posterior monolithic zirconia STs and FDPs.

  13. Tooth replacements in young adults with severe hypodontia: Orthodontic space closure, dental implants, and tooth-supported fixed dental prostheses. A follow-up study.

    Science.gov (United States)

    Hvaring, Christina L; Øgaard, Bjørn; Birkeland, Kari

    2016-10-01

    Children with severe hypodontia have a substantial impairment of their dental health starting early in life. The purpose of this study was to describe types and locations of substitutes for missing teeth in patients with severe hypodontia and to compare the crown and soft tissue morphologies of orthodontic space closure, dental implants, and tooth-supported fixed dental prostheses for replacing teeth in the anterior region. Fifty patients missing 6 or more teeth and aged 18 years or older (mean age, 25.6 years) took part in a follow-up study. The patients were examined clinically with panoramic radiographs and clinical photographs. Crown and soft tissue variables (mucosal discoloration, crown morphology, color, and papilla index) were compared for orthodontic space closure, dental implant fixtures, and fixed dental prostheses. Dental implants, orthodontic space closure, and retaining deciduous teeth were the most commonly prescribed treatments. Persisting deciduous teeth showed a good survival rate at the follow-up examination. Mucosal discoloration was seen only for implant fixtures and was evident for almost all fixtures in the anterior mandible and two thirds of those in the anterior maxilla. The papilla index scored poorer for both implant fixtures and fixed dental prostheses compared with orthodontic space closure. Dental implants in the anterior region proved to be an inadequate treatment modality in patients with severe hypodontia because of pronounced mucosal discoloration. Copyright © 2016 American Association of Orthodontists. Published by Elsevier Inc. All rights reserved.

  14. Tribology of total hip arthroplasty prostheses: What an orthopaedic surgeon should know.

    Science.gov (United States)

    Rieker, Claude B

    2016-02-01

    Articulating components should minimise the generation of wear particles in order to optimize long-term survival of the prosthesis.A good understanding of tribological properties helps the orthopaedic surgeon to choose the most suitable bearing for each individual patient.Conventional and highly cross-linked polyethylene articulating either with metal or ceramic, ceramic-on-ceramic and metal-on-metal are the most commonly used bearing combinations.All combinations of bearing surface have their advantages and disadvantages. An appraisal of the individual patient's objectives should be part of the assessment of the best bearing surface. Cite this article: Rieker CB. Tribology of total hip arthroplasty prostheses: what an orthopaedic surgeon should know. EFORT Open Rev 2016;1:52-57. DOI: 10.1302/2058-5241.1.000004.

  15. Wireless technologies for closed-loop retinal prostheses

    Science.gov (United States)

    Ng, David C.; Bai, Shun; Yang, Jiawei; Tran, Nhan; Skafidas, Efstratios

    2009-12-01

    In this paper, we discuss various technologies needed to develop retinal prostheses with wireless power and data telemetry operation. In addition to the need to communicate with the implanted device, supply of power to the retinal prosthesis is especially difficult. This is because, in the implanted state, the device is not fixed in position due to constant motion of the eye. Furthermore, a retinal prosthesis incorporating a high density electrode array of more than 1000 electrodes is expected to consume approximately 45 mW of power and require 300 kbps of image and stimulation data. The front end of the wireless power and data transmission, the antenna, needs to be small compared to the size of the eye. Also, the wireless module is expected to operate in the reactive near-field region due to small separation between the transmit and receive antennas compared to their size and corresponding operating wavelength. An inductive link is studied as a means to transfer power and for data telemetry between the implant and external unit. In this work, the use of integrated circuit and microfabrication technologies for implementing inductive links is discussed. A closed-loop approach is taken to improve performance and reach optimum operation condition. Design and simulation data are presented as the basis for development of viable wireless module prototypes.

  16. Optimization of scan time in MRI for total hip prostheses. SEMAC tailoring for prosthetic implants containing different types of metals

    Energy Technology Data Exchange (ETDEWEB)

    Deligianni, X. [University of Basel Hospital, Basel (Switzerland). Div. of Radiological Physics; Merian Iselin Klinik, Basel (Switzerland). Inst. of Radiology; Bieri, O. [University of Basel Hospital, Basel (Switzerland). Div. of Radiological Physics; Elke, R. [Orthomerian, Basel (Switzerland); Wischer, T.; Egelhof, T. [Merian Iselin Klinik, Basel (Switzerland). Inst. of Radiology

    2015-12-15

    Magnetic resonance imaging (MRI) of soft tissues after total hip arthroplasty is of clinical interest for the diagnosis of various pathologies that are usually invisible with other imaging modalities. As a result, considerable effort has been put into the development of metal artifact reduction MRI strategies, such as slice encoding for metal artifact correction (SEMAC). Generally, the degree of metal artifact reduction with SEMAC directly relates to the overall time spent for acquisition, but there is no specific consensus about the most efficient sequence setup depending on the implant material. The aim of this article is to suggest material-tailored SEMAC protocol settings. Five of the most common total hip prostheses (1. Revision prosthesis (S-Rom), 2. Titanium alloy, 3. Mueller type (CoNiCRMo alloy), 4. Old Charnley prosthesis (Exeter/Stryker), 5. MS-30 stem (stainless-steel)) were scanned on a 1.5 T MRI clinical scanner with a SEMAC sequence with a range of artifact-resolving slice encoding steps (SES: 2 - 23) along the slice direction (yielding a total variable scan time ranging from 1 to 10 min). The reduction of the artifact volume in comparison with maximal artifact suppression was evaluated both quantitatively and qualitatively in order to establish a recommended number of steps for each case. The number of SES that reduced the artifact volume below approximately 300 mm{sup 3} ranged from 3 to 13, depending on the material. Our results showed that although 3 SES steps can be sufficient for artifact reduction for titanium prostheses, at least 11 SES should be used for prostheses made of materials such as certain alloys of stainless steel. Tailoring SES to the implant material and to the desired degree of metal artifact reduction represents a simple tool for workflow optimization of SEMAC imaging near total hip arthroplasty in a clinical setting.

  17. Optimization of scan time in MRI for total hip prostheses. SEMAC tailoring for prosthetic implants containing different types of metals

    International Nuclear Information System (INIS)

    Deligianni, X.; Wischer, T.; Egelhof, T.

    2015-01-01

    Magnetic resonance imaging (MRI) of soft tissues after total hip arthroplasty is of clinical interest for the diagnosis of various pathologies that are usually invisible with other imaging modalities. As a result, considerable effort has been put into the development of metal artifact reduction MRI strategies, such as slice encoding for metal artifact correction (SEMAC). Generally, the degree of metal artifact reduction with SEMAC directly relates to the overall time spent for acquisition, but there is no specific consensus about the most efficient sequence setup depending on the implant material. The aim of this article is to suggest material-tailored SEMAC protocol settings. Five of the most common total hip prostheses (1. Revision prosthesis (S-Rom), 2. Titanium alloy, 3. Mueller type (CoNiCRMo alloy), 4. Old Charnley prosthesis (Exeter/Stryker), 5. MS-30 stem (stainless-steel)) were scanned on a 1.5 T MRI clinical scanner with a SEMAC sequence with a range of artifact-resolving slice encoding steps (SES: 2 - 23) along the slice direction (yielding a total variable scan time ranging from 1 to 10 min). The reduction of the artifact volume in comparison with maximal artifact suppression was evaluated both quantitatively and qualitatively in order to establish a recommended number of steps for each case. The number of SES that reduced the artifact volume below approximately 300 mm 3 ranged from 3 to 13, depending on the material. Our results showed that although 3 SES steps can be sufficient for artifact reduction for titanium prostheses, at least 11 SES should be used for prostheses made of materials such as certain alloys of stainless steel. Tailoring SES to the implant material and to the desired degree of metal artifact reduction represents a simple tool for workflow optimization of SEMAC imaging near total hip arthroplasty in a clinical setting.

  18. Rough surfaces of titanium and titanium alloys for implants and prostheses

    International Nuclear Information System (INIS)

    Conforto, E.; Aronsson, B.-O.; Salito, A.; Crestou, C.; Caillard, D.

    2004-01-01

    Titanium and titanium alloys for dental implants and hip prostheses were surface-treated and/or covered by metallic or ceramic rough layers after being submitted to sand blasting. The goal of these treatments is to improve the surface roughness and consequently the osteointegration, the fixation, and the stability of the implant. The microstructure of titanium and titanium alloys submitted to these treatments has been studied and correlated to their mechanical behavior. As-treated/covered and mechanically tested surfaces were characterized by scanning electron microscopy (SEM). Structural analyses performed by transmission electron microscopy (TEM), mainly in cross-section, reveal the degree of adherence and cohesion between the surface layer and the substrate (implant). We observed that, although the same convenient surface roughness was obtained with the two types of process, many characteristics as structural properties and mechanical behavior are very different

  19. Cyclic stress-strain behavior of polymeric nonwoven structures for the use as artificial leaflet material for transcatheter heart valve prostheses

    Directory of Open Access Journals (Sweden)

    Arbeiter Daniela

    2017-09-01

    Full Text Available Xenogenic leaflet material, bovine and porcine pericardium, is widely used for the fabrication of surgically implanted and transcatheter heart valve prostheses. As a biological material, long term durability of pericardium is limited due to calcification, degeneration and homogeneity. Therefore, polymeric materials represent a promising approach for a next generation of artificial heart valve leaflets with improved durability. Within the current study we analyzed the mechanical performance of polymeric structures based on elastomeric materials. Polymeric cast films were prepared and nonwovens were manufactured in an electrospinning process. Analysis of cyclic stress-strain behavior was performed, using a universal testing machine. The uniaxial cyclic tensile experiments of the elastomeric samples yielded a non-linear elastic response due to viscoelastic behavior with hysteresis. Equilibrium of stress-strain curves was found after a specific number of cycles, for cast films and nonwovens, respectively. In conclusion, preconditioning was found obligatory for the evaluation of the mechanical performance of polymeric materials for the use as artificial leaflet material for heart valve prostheses.

  20. Electric stimulation with sinusoids and white noise for neural prostheses

    Directory of Open Access Journals (Sweden)

    Daniel K Freeman

    2010-02-01

    Full Text Available We are investigating the use of novel stimulus waveforms in neural prostheses to determine whether they can provide more precise control over the temporal and spatial pattern of elicited activity as compared to conventional pulsatile stimulation. To study this, we measured the response of retinal ganglion cells to both sinusoidal and white noise waveforms. The use of cell-attached and whole cell patch clamp recordings allowed the responses to be observed without significant obstruction from the stimulus artifact. Electric stimulation with sinusoids elicited robust responses. White noise analysis was used to derive the linear kernel for the ganglion cell’s spiking response as well as for the underlying excitatory currents. These results suggest that in response to electric stimulation, presynaptic retinal neurons exhibit bandpass filtering characteristics with peak response that occur 25ms after onset. The experimental approach demonstrated here may be useful for studying the temporal response properties of other neurons in the CNS.

  1. Assessment of Body-Powered Upper Limb Prostheses by Able-Bodied Subjects, using the Box and Blocks Test and the Nine Hole Peg Test

    NARCIS (Netherlands)

    Haverkate, L.; Smit, G.; Plettenburg, D.H.

    2014-01-01

    Study Design: Experimental trial. Background: The functional performance of currently available body-powered prostheses is unknown. Objective: The goal of this study was to objectively assess and compare the functional performance of three commonly used body-powered upper limb terminal devices.

  2. Full mouth rehabilitation with retrievable metal-ceramic implant-supported fixed prostheses for a young patient with atrophic jaws: a clinical report.

    Science.gov (United States)

    Ameri, Narges; Alikhasi, Marzieh; Rezayani, Vida

    2017-09-01

    Treatment of atrophic edentulous jaws with implant-supported fixed prostheses is one of the most complicated challenges in dentistry. This clinical report describes the prosthesis which consists of screw retained frameworks with individual cement retained crowns which combines the advantages of the screw retained restoration with the advantage of cement retained.

  3. To what extent does the longevity of fixed dental prostheses depend on the function of the cement? Working Group 4 materials : cementation

    NARCIS (Netherlands)

    Edelhoff, Daniel; Ozcan, Mutlu

    Aims/Background: The objective of this review was to define the impact of cementation mode on the longevity of different types of single tooth restorations and fixed dental prostheses (FDP). Methods: Literature search by PubMed as the major database was used utilizing the terms namely, adhesive

  4. Percutaneous bone cement refixation of aseptically loose hip prostheses: the effect of interface tissue removal on injected cement volumes

    Energy Technology Data Exchange (ETDEWEB)

    Malan, Daniel F. [Leiden University Medical Center, Department of Orthopaedics, Leiden (Netherlands); Delft University of Technology, Department of Intelligent Systems, Delft (Netherlands); Valstar, Edward R. [Leiden University Medical Center, Department of Orthopaedics, Leiden (Netherlands); Delft University of Technology, Department of Biomechanical Engineering, Delft (Netherlands); Nelissen, Rob G.H.H. [Leiden University Medical Center, Department of Orthopaedics, Leiden (Netherlands)

    2014-11-15

    To quantify whether injected cement volumes differed between two groups of patients who underwent experimental minimally invasive percutaneous cement injection procedures to stabilize aseptically loose hip prostheses. One patient group was preoperatively treated using gene-directed enzyme prodrug therapy to remove fibrous interface tissue, while the other group received no preoperative treatment. It was hypothesized that cement penetration may have been inhibited by the presence of fibrous interface tissue in periprosthetic lesions. We analyzed 17 patients (14 female, 3 male, ages 72-91, ASA categories 2-4) who were treated at our institution. Osteolytic lesions and injected cement were manually delineated using 3D CT image segmentation, and the deposition of injected cement was quantified. Patients who underwent preoperative gene-directed enzyme therapy to remove fibrous tissue exhibited larger injected cement volumes than those who did not. The observed median increase in injected cement volume was 6.8 ml. Higher cement leakage volumes were also observed for this group. We conclude that prior removal of periprosthetic fibrous interface tissue may enable better cement flow and penetration. This might lead to better refixation of aseptically loosened prostheses. (orig.)

  5. Embodying prostheses - how to let the body welcome assistive devices. Comment on "The embodiment of assistive devices-from wheelchair to exoskeleton" by M. Pazzaglia and M. Molinari

    Science.gov (United States)

    Longo, Matthew R.; Sadibolova, Renata; Tamè, Luigi

    2016-03-01

    A growing body of research has focused on the development of assistive devises to improve the recovery and ameliorate the quality of life of people suffering from spinal cord injuries (SCI). In their stimulating and timely paper, Pazzaglia and Molinari [1] review the significant progress made by biotechnology studies in providing increasing sophisticated assistive tools (e.g., prostheses and exoskeletons) that extend the functionality of patients' bodies. However, despite this extraordinary technological effort [2], it remains uncertain how these devices can be appropriately embedded into the mental representation of the body. Here, we wish to amplify the points raised by Pazzaglia and Molinari by discussing three challenges facing work on embodying prostheses raised by experimental research on body representation.

  6. Fit Analysis of Different Framework Fabrication Techniques for Implant-Supported Partial Prostheses.

    Science.gov (United States)

    Spazzin, Aloísio Oro; Bacchi, Atais; Trevisani, Alexandre; Farina, Ana Paula; Dos Santos, Mateus Bertolini

    2016-01-01

    This study evaluated the vertical misfit of implant-supported frameworks made using different techniques to obtain passive fit. Thirty three-unit fixed partial dentures were fabricated in cobalt-chromium alloy (n = 10) using three fabrication methods: one-piece casting, framework cemented on prepared abutments, and laser welding. The vertical misfit between the frameworks and the abutments was evaluated with an optical microscope using the single-screw test. Data were analyzed using one-way analysis of variance and Tukey test (α = .05). The one-piece casted frameworks presented significantly higher vertical misfit values than those found for framework cemented on prepared abutments and laser welding techniques (P Laser welding and framework cemented on prepared abutments are effective techniques to improve the adaptation of three-unit implant-supported prostheses. These techniques presented similar fit.

  7. A retrospective 3- to 5-year study of the reconstruction of oral function using implant-supported prostheses in patients with hypohidrotic ectodermal dysplasia.

    Science.gov (United States)

    Zou, Duohong; Wu, Yiqun; Wang, Xu Dong; Huang, Wei; Zhang, Zhiyong; Zhang, Zhiyuan

    2014-10-01

    The aim of this study was to evaluate oral function rehabilitation in patients with hypohidrotic ectodermal dysplasia (HED) using implant-supported prostheses based on bone augmentation. From September 2005 and March 2009, 25 HED patients were chosen for clinical data analysis in this study. The criteria for patient selection included the following: the display of clinical features of HED, the number of congenitally missing teeth (>5), the patient age (>16 years), the patient's willingness, and the patient's tolerance for bone graft surgery and implant placement. Follow-up evaluations were initiated from the time of implant prosthetic placement and scheduled annually for 3-5 years. The effects of oral function reconstruction were assessed based on the cumulative survival and success rates of implants, the health of the peri-implant area, and the degree of patient satisfaction. Twenty-five HED patients received 169 conventional implants and 10 zygomatic implants (179 total implants). During 3-5 years of post-loading evaluations, 5 of the 179 implants failed and 3 implants were removed. The 3-year success and cumulative survival rates were 97.2% and 98.3%, respectively. Furthermore, periodontal probing and radiographic assessments showed that the 3-year incidence of peri-implantitis was 4.5%. Finally, HED patients expressed high degrees of satisfaction with their facial contours, masticatory function, pronunciation ability, and comfort with the implant-supported prostheses. The results of this 3- to 5-year retrospective study indicate that the oral function of HED patients can be effectively reconstructed using bone augmentation and implant-supported prostheses; however, longer term results are warranted in the future.

  8. Metal artifact reduction software used with abdominopelvic dual-energy CT of patients with metal hip prostheses: assessment of image quality and clinical feasibility.

    Science.gov (United States)

    Han, Seung Chol; Chung, Yong Eun; Lee, Young Han; Park, Kwan Kyu; Kim, Myeong Jin; Kim, Ki Whang

    2014-10-01

    The objective of our study was to determine the feasibility of using Metal Artifact Reduction (MAR) software for abdominopelvic dual-energy CT in patients with metal hip prostheses. This retrospective study included 33 patients (male-female ratio, 19:14; mean age, 63.7 years) who received total hip replacements and 20 patients who did not have metal prostheses as the control group. All of the patients underwent dual-energy CT. The quality of the images reconstructed using the MAR algorithm and of those reconstructed using the standard reconstruction was evaluated in terms of the visibility of the bladder wall, pelvic sidewall, rectal shelf, and bone-prosthesis interface and the overall diagnostic image quality with a 4-point scale. The mean and SD attenuation values in Hounsfield units were measured in the bladder, pelvic sidewall, and rectal shelf. For validation of the MAR interpolation algorithm, pelvis phantoms with small bladder "lesions" and metal hip prostheses were made, and images of the phantoms both with and without MAR reconstruction were evaluated. Image quality was significantly better with MAR reconstruction than without at all sites except the rectal shelf, where the image quality either had not changed or had worsened after MAR reconstruction. The mean attenuation value was changed after MAR reconstruction to its original expected value at the pelvic sidewall (p software with dual-energy CT decreases metal artifacts and increases diagnostic confidence in the assessment of the pelvic cavity but also introduces new artifacts that can obscure pelvic structures.

  9. Immediately loaded implants supporting fixed prostheses in the edentulous maxilla: a preliminary clinical and radiologic report.

    Science.gov (United States)

    Bergkvist, Göran; Sahlholm, Sten; Karlsson, Ulf; Nilner, Krister; Lindh, Christina

    2005-01-01

    To evaluate the survival rate of immediately loaded ITI sand-blasted, large-grit, acid-etched (SLA) solid-screw dental implants in the edentulous maxilla after 8 months of loading. Twenty-eight patients (mean age 63 years) with edentulous maxillae each received 6 implants and 1 implant-supported fixed provisional prosthesis within 24 hours after surgery. After a mean healing time of 15 weeks, the patient received a definitive, screw-retained, implant-supported fixed prosthesis. A total of 168 implants were placed. Clinical parameters were registered after 1 month of loading with the implant-supported fixed prostheses as well as 8 months after implant placement. Radiologic examinations and assessments were made at implant placement and after 8 months. The mean marginal bone level at implant placement was 1.6 mm (range 0 to 5.1; SD 1.1) apical of the reference point (the implant shoulder). The mean marginal bone level at the 8-month follow-up was 3.2 mm (range 0.4 to 5.9; SD 1.1) apical of the reference point. Three implants failed during the healing period. The improved results in the present study might be a result of the positive effect of splinting the implants immediately after placement. ITI SLA solid-screw implants immediately loaded (ie, loaded within 24 hours of placement) and supporting fixed prostheses had successful survival rates after 8 months. The present results constitute a solid baseline for future follow-up studies.

  10. Diagnostics of 'non-acute' vascular prosthesis infection using {sup 18}F-FDG PET/CT: our experience with 96 prostheses

    Energy Technology Data Exchange (ETDEWEB)

    Spacek, M. [First Faculty of Medicine and General Teaching Hospital, Second Clinical Department of Cardiovascular Surgery, Prague (Czech Republic); Na Homolce Hospital, Department of Vascular Surgery, Prague (Czech Republic); Belohlavek, O.; Votrubova, J. [PET Centre, Na Homolce Hospital, Department of Nuclear Medicine, Prague (Czech Republic); Sebesta, P.; Stadler, P. [Na Homolce Hospital, Department of Vascular Surgery, Prague (Czech Republic)

    2009-05-15

    Vascular prosthesis infection (VPI) is a life-threatening complication that occurs in 0.5-5% of prostheses. Low-grade infections in non-acute patients are a diagnostic challenge requiring a new method with good diagnostic accuracy. The aim of this work was to define the accuracy of {sup 18}F-FDG PET/CT in these settings and to identify essential parameters of the evaluation. PET/CT was performed prospectively in 76 consecutive patients with a total of 96 vascular prosthetic grafts in which infection was suspected. PET/CT scans were analysed in terms of the presence and intensity of focal and diffuse FDG uptake, the presence of an anastomotic pseudoaneurysm, the presence of an irregular boundary of infiltration, a combination of these, and the uptake ratio between the graft and blood background. The gold standard was based on operative/histopathological finding or a clinical follow up of >6 months. Among the various assessed parameters only focal FDG uptake and an irregular graft boundary were significant predictors of VPI. Focal intense FDG uptake together with an irregular boundary of the lesion on CT scan predicted VPI with 97% probability, while smooth lesion boundaries and no focal FDG uptake predicted a probability of VPI of less than 5%. Even in lesions with nondiagnostic inhomogeneous focal FDG uptake (18/96) an irregular boundary effectively helped in decision-making with a probability of 28% (smooth) or 77% (irregular) for VPI. PET/CT gave reliable results with an accuracy >95% in 75% of prostheses. PET/CT can identify those prostheses (25% of prosthesis) for which its diagnostic accuracy is diminished to 70-75%. In our series PET/CT was an excellent diagnostic modality for suspected VPI. (orig.)

  11. An Evaluation of the Gap Sizes of 3-Unit Fixed Dental Prostheses Milled from Sintering Metal Blocks

    OpenAIRE

    Jung, Jae-Kwan

    2017-01-01

    This study assessed the clinical acceptability of sintering metal-fabricated 3-unit fixed dental prostheses (FDPs) based on gap sizes. Ten specimens were prepared on research models by milling sintering metal blocks or by the lost-wax technique (LWC group). Gap sizes were assessed at 12 points per abutment (premolar and molar), 24 points per specimen (480 points in a total in 20 specimens). The measured points were categorized as marginal, axial wall, and occlusal for assessment in a silicone...

  12. Complete integration of technology for improved reproduction of auricular prostheses.

    Science.gov (United States)

    Watson, Jason; Hatamleh, Muhanad M

    2014-05-01

    The accurate reproduction of the form and surface details of missing body structures is an essential part of any successful prosthetic rehabilitation. It helps mask the prosthesis and gives confidence to the patient. This clinical report details the integration of multiple in-house digital technologies of laser scanning, rapid prototyping, and digital color scanning and formulating to improve the shape, texture, orientation, and color of auricular prostheses for 3 patients with missing unilateral ears. A structured light laser scanner was used to digitize the patient's nondefect ear. The digitized data were then manipulated in specialist software and mirrored to reflect the opposing side. A rapid prototyping machine was used to manufacture a 3-dimensional (3D) model of the soft tissue required. This 3D mirrored ear model allowed the accurate reproduction of missing soft tissue. A color spectrometer was used to accurately reproduce the skin tones digitally and physically. Copyright © 2014 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.

  13. Reinforcement of a PMMA resin for fixed interim prostheses with nanodiamonds.

    Science.gov (United States)

    Protopapa, Popi; Kontonasaki, Eleana; Bikiaris, Dimitrios; Paraskevopoulos, Konstantinos M; Koidis, Petros

    2011-01-01

    The aim of this study was to investigate the possible reinforcement of Nanodiamonds (ND) in a PMMA resin for fixed interim restorations. The fracture toughness (K(Ic)), impact strength and the dynamic thermomechanical properties (T(g), E´, E´´, tanδ) of a series of PMMA-ND nanocomposites with different amounts of ND were evaluated. The fracture toughness increased as the ND percentage increased up to 0.38% wt but a greater amount of ND induced a decrease in K(Ic). Impact strength and Young's modulus were also increased by increasing nanoparticles content, indicating the reinforcing effect of ND. Dynamic mechanical properties were also affected. By increasing the ND content an increase of storage modulus was recorded, while glass transition was shifted at higher temperatures. Under the limitations of this study, it can be suggested that reinforcing PMMA with ND nanoparticles -especially at low concentrations- may increase the overall performance of fixed interim prostheses.

  14. All-ceramic inlay-retained fixed dental prostheses for replacing posterior missing teeth: A systematic review.

    Science.gov (United States)

    Castillo-Oyagüe, Raquel; Sancho-Esper, Rocío; Lynch, Christopher D; Suárez-García, María-Jesús

    2018-01-01

    To evaluate the current status of all-ceramic inlay-retained fixed dental prostheses (CIR-FDPs) for the replacement of posterior teeth. Screening of titles and abstracts, full-text analysis for inclusion eligibility, quality assessment, data extraction and evaluation of the scientific evidence were performed independently by two reviewers. The electronic databases MEDLINE/PubMed, EMBASE, Cochrane Central Register of Controlled Trials, and Compludoc were searched with no restriction to publication date or language. The quality of the studies was evaluated through: the original 'QDP' ('Questionnaire for selecting articles on Dental Prostheses') (for research papers); the 'Guidelines for managing overviews' of the Evidence-Based Medicine Working Group (for reviews); the Cochrane risk of bias tool; and the GRADE scale for grading scientific evidence. This review started with 4942 articles, which were narrowed down to 23 according to the selection criteria. The data was not statistically treated because of the heterogeneity of the studies. Zirconia-based CIR-FDPs may be recommended for restoring posterior single missing teeth, although the prosthesis/tooth bonded interface has yet to be improved. The addition of lateral wings to the classical inlay preparation seems promising. The weakest parts of CIR-FDPs are the connectors and retainers, while caries and endodontic problems are the most common biological complications. The fabrication of CIR-FDPs with monolithic zirconia may eliminate chipping problems. A three-unit CIR-FDP is a viable treatment option for replacing a posterior missing tooth. Appropriate case selection, abutment preparation and luting procedures may be decisive for clinical success. Copyright © 2017 Japan Prosthodontic Society. Published by Elsevier Ltd. All rights reserved.

  15. Oral health-related quality of life of implant-supported overdentures versus conventional complete prostheses: Retrospective study of a cohort of edentulous patients.

    Science.gov (United States)

    Fernandez-Estevan, Lucia; Selva-Otaolaurruchi, Eduardo J; Montero, Javier; Sola-Ruiz, Fernanda

    2015-07-01

    This work aims to confirm if implant-supported overdentures are a good treatment option for edentulous patients and offer an improvement in quality of life compared with traditional complete prostheses (dentures). This retrospective clinical descriptive study included three evaluation groups: validation group (n=57); control group of patients with complete removeable prostheses (n=56); study group of patients with implant-supported overdentures retained with the Locator® system (n=80). The study also validated the Oral Health Impact Profile-20 questionnaire. Individual protocols were created that included socio-demographic data, the Oral Health Impact Profile-20 (OHIP-20) questionnaire and Oral Satisfaction Scale (OSS). Descriptive and bivariate statistical analysis was carried out applying χ², Pearson, Kruskal-Wallis, and Student t tests, transferring data into SPSS-Windows® software from a Microsoft® Excel spreadsheet. The OHIP-20 proved to be a valid instrument and provided reliable assessment of health-related quality of life among both the Spanish general population and edentulous patients. The control and study groups proved comparable, showing socio-demographic homogeneity. For patients with overdentures retained by means of the Locator® system, these restorations had significantly lower impact on quality of life (19 vs 33), both generally and for each individual questionnaire item, and much higher satisfaction with the state of their oral cavities (8.3 vs 5.3) than patients wearing dentures; both sets of data showed a direct linear relationship, so that as the level of impact on quality of life increased, perceived oral satisfaction worsened. Patients rehabilitated with implant supported overdentures retained by the Locator® system, presented significantly lower levels of impact on their quality of life and significantly higher oral satisfaction than patients with conventional complete prostheses.

  16. Monoscopic photogrammetry to obtain 3D models by a mobile device: a method for making facial prostheses.

    Science.gov (United States)

    Salazar-Gamarra, Rodrigo; Seelaus, Rosemary; da Silva, Jorge Vicente Lopes; da Silva, Airton Moreira; Dib, Luciano Lauria

    2016-05-25

    The aim of this study is to present the development of a new technique to obtain 3D models using photogrammetry by a mobile device and free software, as a method for making digital facial impressions of patients with maxillofacial defects for the final purpose of 3D printing of facial prostheses. With the use of a mobile device, free software and a photo capture protocol, 2D captures of the anatomy of a patient with a facial defect were transformed into a 3D model. The resultant digital models were evaluated for visual and technical integrity. The technical process and resultant models were described and analyzed for technical and clinical usability. Generating 3D models to make digital face impressions was possible by the use of photogrammetry with photos taken by a mobile device. The facial anatomy of the patient was reproduced by a *.3dp and a *.stl file with no major irregularities. 3D printing was possible. An alternative method for capturing facial anatomy is possible using a mobile device for the purpose of obtaining and designing 3D models for facial rehabilitation. Further studies must be realized to compare 3D modeling among different techniques and systems. Free software and low cost equipment could be a feasible solution to obtain 3D models for making digital face impressions for maxillofacial prostheses, improving access for clinical centers that do not have high cost technology considered as a prior acquisition.

  17. Edentulism and dental prostheses in the elderly: impact on quality of life measured with EuroQol--visual analog scale (EQ-VAS).

    Science.gov (United States)

    Cano-Gutiérrez, Carlos; Borda, Miguel G; Arciniegas, Antonio J; Borda, Claudia X

    2015-01-01

    The objective of this study was to measure the impact of edentulism and dental prostheses on quality of life (QOL) in older adults in Bogota, Colombia. Edentulism is a frequent condition in older adults and has great impact on their QOL. No epidemiological data are currently available on edentulism among older adults in Colombia. Data were obtained from the SABE-Bogota study, a cross-sectional study conducted in 2012, and used to analyze the EQ-VAS (Visual Analog Scale) from the EuroQol instrument to measure the perception of quality of life (QOL) in relation to edentulism. The study included 2,000 individuals over 60 years old. The Spearman-Rho correlation was used to analyze the correlation between EQ-VAS and edentulism. Chi-Square, ANOVA and t-test were used to study the differences in EQ-VAS scores between edentulous and healthy subjects. Statistical significance was set at peducation were related to edentulism. Individuals with fewer teeth and dental prostheses had lower EQ-VAS scores (pmeasuring the perception of QOL in dental health scenarios. Edentulism significantly affects QOL in older adults and the use of dental prosthesis does not improve the perception of QOL.

  18. Hydrogel-Electrospun Fiber Mat Composite Coatings for Neural Prostheses

    Directory of Open Access Journals (Sweden)

    Ning eHan

    2011-03-01

    Full Text Available Achieving stable, long-term performance of implanted neural prosthetic devices has been challenging because of implantation related neuron loss and a foreign body response that results in encapsulating glial scar formation. To improve neuron-prosthesis integration and form chronic, stable interfaces, we investigated the potential of neurotrophin-eluting hydrogel-electrospun fiber mat (EFM composite coatings. In particular, poly(ethylene glycol-poly(ε-caprolactone (PEGPCL hydrogel- poly(ε-caprolactone (PCL EFM composites were applied as coatings for multielectrode arrays (MEAs. Coatings were stable and persisted on electrode surfaces for over 1 month under an agarose gel tissue phantom and over 9 months in a PBS immersion bath. To demonstrate drug release, a neurotrophin, nerve growth factor (NGF, was loaded in the PEGPCL hydrogel layer, and coating cytotoxicity and sustained NGF release were evaluated using a PC12 cell culture model. Quantitative MTT assays showed that these coatings had no significant toxicity toward PC12 cells, and neurite extension at day 7 and 14 confirmed sustained release of NGF at biologically significant concentrations for at least 2 weeks. Our results demonstrate that hydrogel-EFM composite materials can be applied to neural prostheses as a means to improve neuron-electrode proximity and enhance long-term device performance and function.

  19. Alumina-fluorapatite composite coating deposited by atmospheric plasma spraying: An agent of cohesion between bone and prostheses

    International Nuclear Information System (INIS)

    Ghorbel, Halima Feki; Guidara, Awatef; Danlos, Yoan; Bouaziz, Jamel; Coddet, Christian

    2017-01-01

    In order to remedy the poor biological and tribological properties of 316 L stainless steel (SS), plasma sprayed bio-ceramic coatings have been widely investigated. In the present study, a small amount of fluorapatite (Fap) was introduced into alumina in order to enhance its bioactivity. The powder feedstock was sprayed on 316 L substrate by Atmospheric Plasma Spraying (APS) technology. The roughness profiles and average roughness values were determined using 3D profilometry. The cross sectional morphologies of the coatings were examined by scanning electron microscopy (SEM). Adhesive strength, micro-hardness and tribological properties were also examined. Experimental results revealed that Al 2 O 3 /Fap coating showed a good microhardness property revealing that the calcium aluminates were quite effective in improving the Fap mechanical behavior. The tribological characteristics of both alumina and alumina-Fap coating were also compared to those of classical hydroxyapatite (Hap) coatings as reported in the literature. The main finding of this work was that Fap coating can contribute to the cohesion between bone and prostheses and thus ensure a more durable and reliable prostheses. - Highlights: • This research addresses tissue engineering and novel biomaterials consisting of combination of Al 2 O 3 and Fap. • The addition of Fap to alumina results in higher coating porosity, which may be beneficial for the mechanical fixture by bone ingrowth. • Adhesion strength of the alumina ceramic coating is improved by the Fap addition • The presence of CaO in the synthesized Fap may help in improving the mechanical resistance through to formation of the calcium aluminates

  20. A review of scalp camouflaging agents and prostheses for individuals with hair loss.

    Science.gov (United States)

    Donovan, Jeff C H; Shapiro, Ron L; Shapiro, Paul; Zupan, Matt; Pierre-Louis, Margareth; Hordinsky, Maria K

    2012-08-15

    Hair loss is a common problem for both men and women and may impact negatively on self-esteem. A variety of medical and surgical treatment options are available depending on the type of alopecia. Many patients also seek the advice of their physicians about options to hide or reduce the appearance of hair loss with hair prostheses (wigs, hairpieces, and extensions) or hair camouflaging agents (hair fibers, powder cakes, lotions, sprays, hair crayons, and scalp tattooing). Herein, we review current methods to hide or reduce the appearance of hair loss and discuss their associated costs, advantages, and disadvantages. Knowledge of products available to cover scalp, eyebrow, and eyelash hair loss may not only better equip clinicians to respond to questions from concerned patients, but may provide additional options to help these patients best cope with their hair loss.

  1. Quantifying metal artefact reduction using virtual monochromatic dual-layer detector spectral CT imaging in unilateral and bilateral total hip prostheses

    Energy Technology Data Exchange (ETDEWEB)

    Wellenberg, R.H.H., E-mail: r.h.wellenberg@amc.uva.nl [Department of Radiology, Academic Medical Centre, Amsterdam (Netherlands); Boomsma, M.F., E-mail: m.f.boomsma@isala.nl [Department of Radiology, Isala, Zwolle (Netherlands); Osch, J.A.C. van, E-mail: j.a.c.van.osch@isala.nl [Department of Radiology, Isala, Zwolle (Netherlands); Vlassenbroek, A., E-mail: alain.vlassenbroek@philips.com [Philips Medical Systems, Brussels (Belgium); Milles, J., E-mail: julien.milles@philips.com [Philips Medical Systems, Eindhoven (Netherlands); Edens, M.A., E-mail: m.a.edens@isala.nl [Department of Innovation and Science, Isala, Zwolle (Netherlands); Streekstra, G.J., E-mail: g.j.streekstra@amc.uva.nl [Department of Radiology, Academic Medical Centre, Amsterdam (Netherlands); Slump, C.H., E-mail: c.h.slump@utwente.nl [MIRA Institute for Biomedical Technology and Technical Medicine, University of Twente, Enschede (Netherlands); Maas, M., E-mail: m.maas@amc.uva.nl [Department of Radiology, Academic Medical Centre, Amsterdam (Netherlands)

    2017-03-15

    Highlights: • Dual-layer detector CT reduces metal artefacts at high monochromatic energies (keV). • 130 keV images were optimal based on quantitative analysis on CNRs. • Optimal keVs varied from 74 to 150 keV for different hip prostheses configurations. • The Titanium alloy resulted in less severe artefacts compared to the Cobalt alloy. • Severe metal artefacts, caused by extensive photon-starvation, were not reduced. - Abstract: Purpose: To quantify the impact of prosthesis material and design on the reduction of metal artefacts in total hip arthroplasties using virtual monochromatic dual-layer detector Spectral CT imaging. Methods: The water-filled total hip arthroplasty phantom was scanned on a novel 128-slice Philips IQon dual-layer detector Spectral CT scanner at 120-kVp and 140-kVp at a standard computed tomography dose index of 20.0 mGy. Several unilateral and bilateral hip prostheses consisting of different metal alloys were inserted and combined which were surrounded by 18 hydroxyapatite calcium carbonate pellets representing bone. Images were reconstructed with iterative reconstruction and analysed at monochromatic energies ranging from 40 to 200 keV. CT numbers in Hounsfield Units (HU), noise measured as the standard deviation in HU, signal-to-noise-ratios (SNRs) and contrast-to-noise-ratios (CNRs) were analysed within fixed regions-of-interests placed in and around the pellets. Results: In 70 and 74 keV virtual monochromatic images the CT numbers of the pellets were similar to 120-kVp and 140-kVp polychromatic results, therefore serving as reference. A separation into three categories of metal artefacts was made (no, mild/moderate and severe) where pellets were categorized based on HU deviations. At high keV values overall image contrast was reduced. For mild/moderate artefacts, the highest average CNRs were attained with virtual monochromatic 130 keV images, acquired at 140-kVp. Severe metal artefacts were not reduced. In 130 keV images

  2. Mechanical compatibility of sol-gel annealing with titanium for orthopaedic prostheses.

    Science.gov (United States)

    Greer, Andrew I M; Lim, Teoh S; Brydone, Alistair S; Gadegaard, Nikolaj

    2016-01-01

    Sol-gel processing is an attractive method for large-scale surface coating due to its facile and inexpensive preparation, even with the inclusion of precision nanotopographies. These are desirable traits for metal orthopaedic prostheses where ceramic coatings are known to be osteoinductive and the effects may be amplified through nanotexturing. However there are a few concerns associated with the application of sol-gel technology to orthopaedics. Primarily, the annealing stage required to transform the sol-gel into a ceramic may compromise the physical integrity of the underlying metal. Secondly, loose particles on medical implants can be carcinogenic and cause inflammation so the coating needs to be strongly bonded to the implant. These concerns are addressed in this paper. Titanium, the dominant material for orthopaedics at present, is examined before and after sol-gel processing for changes in hardness and flexural modulus. Wear resistance, bending and pull tests are also performed to evaluate the ceramic coating. The findings suggest that sol-gel coatings will be compatible with titanium implants for an optimum temperature of 500 °C.

  3. Metallic artifacts caused by dental metal prostheses on PET images. A PET/CT phantom study using different PET/CT scanners

    International Nuclear Information System (INIS)

    Shimamoto, Hiroaki; Kakimoto, Naoya; Murakami, Shumei; Furukawa, Souhei; Fujino, Kouichi; Hamada, Seiki; Shimosegawa, Eku; Hatazawa, Jun

    2009-01-01

    The objective of this study was to investigate the effects of computed tomography (CT) artifacts caused by dental metal prostheses on positron emission tomography (PET) images. A dental arch cast was fixed in a cylindrical water-bath phantom. A spherical phantom positioned in the vicinity of the dental arch cast was used to simulate a tumor. To simulate the tumor imaging, the ratio of the 18 F-fluoro-deoxy-glucose radioactivity concentration of the spherical phantom to that of the water-bath phantom was set at 2.5. A dental bridge composed of a gold-silver-palladium alloy on the right mandibular side was prepared. A spherical phantom was set in the white artifact area on the CT images (site A), in a slightly remote area from the white artifact (site B), and in a black artifact area (site C). A PET/CT scan was performed with and without the metal bridge at each simulated tumor site, and the artifactual influence was evaluated on the axial attenuation-corrected (AC) PET images, in which the simulated tumor produced the strongest accumulation. Measurements were performed using three types of PET/CT scanners (scanners 1 and 2 with CT-based attenuation correction, and 3 with Cesium-137 ( 137 Cs)-based attenuation correction). The influence of the metal bridge was evaluated using the change rate of the SUVmean with and without the metal bridge. At site A, an overestimation was shown (scanner 1: +5.0% and scanner 2: +2.5%), while scanner 3 showed an underestimation of -31.8%. At site B, an overestimation was shown (scanner 1: +2.1% and scanner 2: +2.0%), while scanner 3 showed an underestimation of -2.6%. However, at site C, an underestimation was shown (scanner 1: -25.0%, scanner 2: -32.4%, and scanner 3: -8.4%). When CT is used for attenuation correction in patients with dental metal prostheses, an underestimation of radioactivity of accumulated tracer is anticipated in the dark streak artifact area on the CT images. In this study, the dark streak artifacts of the CT

  4. Are aortic endograft prostheses fully hemo-compatible? A dielectric spectroscopy investigation of the electrical alterations induced on erythrocyte cell membranes

    International Nuclear Information System (INIS)

    Basoli, Antonio; Bordi, Federico; Cametti, Cesare; Faraglia, Vittorio; Gili, Tommaso; Rizzo, Luigi; Taurino, Maurizio

    2007-01-01

    In this paper we present a new approach directed to ascertain the full hemo-compatibility of aortic endograft prostheses based on the measurement of the passive electrical parameters of the erythrocyte cell membrane. The red blood cell membrane, from an electric point of view, is characterized by an electrical permittivity, ε s , which takes into account the structural charged organization of the lipid double layer, and by the electrical conductivity, σ s , which accounts for the ionic transport processes across the membrane. These parameters can be easily measured by means of a radiowave dielectric spectroscopy technique, analyzing the dependence of the electrical impedance of an erythrocyte suspension on the frequency of the applied electric field. In this preliminary report, we investigate the alterations induced, at a membrane level, by two different devices commonly employed for endovascular abdominal aortic aneurysm exclusion, i.e., Excluder (registered) and Zenith (registered) devices, implanted in ten patients. We observe, in all the cases investigated, a statistically significant increase of both the permittivity ε s and electrical conductivity σ s of the erythrocyte membrane upon the prosthesis implant, this increase being higher than about 20% of the un-treated values. Moreover, these alterations remain roughly unaffected 30 days after surgery. These findings suggest that a complete hemo-compatibility of these prostheses is lacking, even if the observed alterations may not have a clinical relevance

  5. Development of a software for the design of custom-made hip prostheses using an open-source rapid application development environment.

    Science.gov (United States)

    Viceconti, M; Testi, D; Gori, R; Zannoni, C

    2000-01-01

    The present work describes a technology transfer project called HIPCOM devoted to the re-engineering of the process used by a medical devices manufacturer to design custom-made hip prostheses. Although it started with insufficient support from the end-user management, a very tight scheduling and a moderate budget, the project developed into what is considered by all partners a success story. In particular, the development of the design software, called HIPCOM Interactive Design Environment (HIDE) was completed in a time shorter than any optimistic expectation. The software was quite stable since its first beta version, and once introduced at the user site it fully replaced the original procedure in less than two months. One year after the early adoption, more than 80 custom-made prostheses had been designed with HIDE and the user had reported only two bugs, both cosmetics. The scope of the present work was to report the development experience and to investigate the reasons for these positive results, with particular reference to the development procedure and the software architecture. The choice of TCL/TK as development language and the adoption of well-defined software architecture were found to be the success key factors. Other important determinants were found to be the adoption of an incremental software engineering strategy, well suited for small to medium projects and the presence in the development staff of a technology transfer expert.

  6. Antifungal activity of components used for decontamination of dental prostheses on the growth of Candida albicans

    Directory of Open Access Journals (Sweden)

    Cíntia Lima Gouveia

    Full Text Available Introduction: The effectiveness of antimicrobial solutions employed in dental prosthesis decontamination is still uncertain. Aim: To evaluate the antifungal activity of cleaners used in the decontamination of dental prostheses on the growth of Candida albicans. Material and method: The evaluated products were: Corega Tabs(r (S1, Sodium Hypochlorite 1% (S2, Sodium Bicarbonate 1% (S3, Hydrogen Peroxide 1% (S4, Chlorhexidine Digluconate 0.12% - Periogard (r (S5, Mouthrinse based on essential oils - Listerine(r (S6, essential oil from Rosmarinus officinalis (rosemary at concentrations of 1% (S7 and 2% (S8. The antifungal activity of the products was evaluated by agar diffusion technique and the determination of microbial death curve of samples of C. albicans (ATCC 90028 in concentration 1.5 × 106 CFU/mL. The tests were performed in triplicate and statistical analysis was made by ANOVA Two-Way and Tukey tests, with the confidence level of 95%. Result: The average of the zones of inhibition growth, in millimeters, obtained for the products were: 0.0 (S1, 44.7 (S2, 0.0 (S3, 21.6 (S4, 10.0 (S5, 6.1 (S6, 0.0 (S7 and 2.4 (S8. Considering the determination of microbial death curve, all products showed a statistical difference (p<0.01 from control (0.85% sodium chloride and S3 groups. Fungal growth less than 2×104 CFU/mL and an accentuation of the microbial death curve were observed after 30 minutes, with exception for S3 and control groups. Conclusion: The studied compounds, with the exception of Sodium Bicarbonate, have antifungal effect against C. albicans, which contribute for dental prostheses hygiene.

  7. Effect of tightening torque on the marginal adaptation of cement-retained implant-supported fixed dental prostheses.

    Science.gov (United States)

    Ghanbarzadeh, Jalil; Dashti, Hossin; Karamad, Reza; Alikhasi, Marzieh; Nakhaei, Mohammadreza

    2015-01-01

    The final position of the abutment changes with the amount of tightening torque. This could eventually lead to loss of passivity and marginal misfit of prostheses. The aim of this study was to evaluate the effect of three different tightening torques on the marginal adaptation of 3-unit cement-retained implant-supported fixed dental prostheses (FDPs). Two implants (Straumann) were inserted in an acrylic block so that one of the implants was placed vertically and the other at a 15° vertical angle. A straight abutment and a 15° angulated abutment were connected to the vertically and obliquely installed implants, respectively, so that the two abutments were parallel. Then, 10 cement-retained FDPs were waxed and cast. Abutments were tightened with 10, 20, and 35 Ncm torques, respectively. Following each tightening torque, FDPs were luted on respective abutments with temporary cement. The marginal adaptation of the retainers was evaluated using stereomicroscope. FDPs were then removed from the abutments and were sectioned at the connector sites. The retainers were luted again on their respective abutments. Luting procedures and marginal adaptation measurement were repeated. Data were analyzed by ANOVA and least significant difference tests (α = 0.05). After cutting the FDP connectors, the independent samples t-test was used to compare misfit values (α = 0.05). Following 10, 20, and 35 Ncm tightening torques, the marginal discrepancy of the retainers of FDPs significantly increased (P marginal discrepancies of these two retainers (P > 0.05). The marginal gap values of angulated abutment retainers (ANRs) were significantly higher than those of the straight abutment after cutting the connectors (P = 0.026). Within the limitations of this study, the marginal misfit of cement-retained FDPs increased continuously when the tightening torque increased. After cutting the connectors, the marginal misfit of the ANRs was higher than those of the straight abutment retainers.

  8. Comparison of Metal-Ceramic and All-Ceramic Three-Unit Posterior Fixed Dental Prostheses: A 3-Year Randomized Clinical Trial.

    Science.gov (United States)

    Nicolaisen, Maj H; Bahrami, Golnosh; Schropp, Lars; Isidor, Flemming

    2016-01-01

    The aim of this randomized clinical study was to compare the 3-year clinical outcome of metal-ceramic fixed dental prostheses (MC-FDPs) and zirconia all-ceramic fixed dental prostheses (AC-FDPs) replacing a posterior tooth. A sample of 34 patients with a missing posterior tooth were randomly chosen to receive either a MC-FDP (n = 17) or an AC-FDP (n = 17). The FDPs were evaluated at baseline and yearly until 3 years after cementation. They were assessed using the California Dental Association assessment system. Periodontal parameters were measured at the abutment teeth, and the contralateral teeth served as control. The statistical unit was the FDP/patient. The survival rates for MC-FDPs and AC-FDPs were 100%. The success rate was 76% and 71% for MC-FDPs and AC-FDPs, respectively. Three technical complications were observed in the MC-FDP group and five in the AC-FDP group, all chipping fractures of the ceramic veneer. Furthermore, one biologic complication in the MC-FDP group (an apical lesion) was observed. No framework fractures occurred. All patients had optimal oral hygiene and showed no bleeding on periodontal probing at any of the recalls. Only minor changes in the periodontal parameters were observed during the 3 years of observation. Three-unit posterior MC-FDPs and AC-FDPs showed similar high survival rates and acceptable success rates after 3 years of function, and ceramic veneer chipping fracture was the most frequent complication for both types of restorations.

  9. Alumina-fluorapatite composite coating deposited by atmospheric plasma spraying: An agent of cohesion between bone and prostheses

    Energy Technology Data Exchange (ETDEWEB)

    Ghorbel, Halima Feki, E-mail: ghorbel.halima@yahoo.fr [LCI, Ecole Nationale d' Ingénieurs de Sfax “ENIS”, Soukra 1173-3038, Sfax (Tunisia); LERMPS, Université de Technologie de Belfort-Montbeliard “UTBM”, Belfort 90010 (France); Guidara, Awatef [LCI, Ecole Nationale d' Ingénieurs de Sfax “ENIS”, Soukra 1173-3038, Sfax (Tunisia); Danlos, Yoan [LERMPS, Université de Technologie de Belfort-Montbeliard “UTBM”, Belfort 90010 (France); Bouaziz, Jamel [LCI, Ecole Nationale d' Ingénieurs de Sfax “ENIS”, Soukra 1173-3038, Sfax (Tunisia); Coddet, Christian [LERMPS, Université de Technologie de Belfort-Montbeliard “UTBM”, Belfort 90010 (France)

    2017-02-01

    In order to remedy the poor biological and tribological properties of 316 L stainless steel (SS), plasma sprayed bio-ceramic coatings have been widely investigated. In the present study, a small amount of fluorapatite (Fap) was introduced into alumina in order to enhance its bioactivity. The powder feedstock was sprayed on 316 L substrate by Atmospheric Plasma Spraying (APS) technology. The roughness profiles and average roughness values were determined using 3D profilometry. The cross sectional morphologies of the coatings were examined by scanning electron microscopy (SEM). Adhesive strength, micro-hardness and tribological properties were also examined. Experimental results revealed that Al{sub 2}O{sub 3}/Fap coating showed a good microhardness property revealing that the calcium aluminates were quite effective in improving the Fap mechanical behavior. The tribological characteristics of both alumina and alumina-Fap coating were also compared to those of classical hydroxyapatite (Hap) coatings as reported in the literature. The main finding of this work was that Fap coating can contribute to the cohesion between bone and prostheses and thus ensure a more durable and reliable prostheses. - Highlights: • This research addresses tissue engineering and novel biomaterials consisting of combination of Al{sub 2}O{sub 3} and Fap. • The addition of Fap to alumina results in higher coating porosity, which may be beneficial for the mechanical fixture by bone ingrowth. • Adhesion strength of the alumina ceramic coating is improved by the Fap addition • The presence of CaO in the synthesized Fap may help in improving the mechanical resistance through to formation of the calcium aluminates.

  10. 5-year clinical and radiostereometric analysis (RSA) follow-up of 39 CUT femoral neck total hip prostheses in young osteoarthritis patients

    Science.gov (United States)

    2012-01-01

    Background As the number of young patients receiving total hip arthroplasty increases, bone-saving implantations facilitating possible future revision, such as the CUT femoral neck prosthesis, are gaining importance. There have been few medium-term results reported for this prosthesis, however, and its migration pattern has not been analyzed. Patients and methods 39 consecutive CUT femoral neck prostheses were implanted in 32 patients, mean age 37 (17–58) years, with symptomatic osteoarthritis and either less than 55 years of age or with an anatomic anomaly preventing implantation of a diaphyseal stem (n = 1). Patients were followed prospectively using routine clinical examination and radiostereometric analysis (RSA) at 6, 12, 26, and 52 weeks postoperatively and annually thereafter. This study evaluated the 5-year follow-up results. Results The mean Harris hip score increased from 26 (3–51) points preoperatively to 84 (66–98), 86 (55–98), and 87 (47–98) points at 3, 12, and 60 months. 3 stems were revised: 1 after luxation following excessive subsidence due to an undersized component and 2 due to persistent strong thigh pain. 5-year survival was 95% (95% CI: 87–100). Initial migration varied widely in magnitude; median total tip migration was 0.42 mm (0.09–9.4) at 6 weeks, 0.92 mm (0.18–5.9) at 1 year, and 1.10 mm (0.13–6.4) at 5 years. Even after high initial migration, stabilization was achieved in 31 of the 35 RSA-evaluable implants. 3 prostheses showed progressive continuous migration throughout the entire follow-up period, and were considered to be loose, suggesting reduced long-term survival. Interpretation Currently, we cannot recommend the CUT femoral neck prosthesis as a routine treatment option in (young) patients requiring THA. The CUT prosthesis may not reach the 90% survival benchmark at 10 years, and the prosthesis is difficult to implant. If initial stabilization is achieved, however, aseptic loosening is unlikely. A good clinical

  11. Standardizing Failure, Success, and Survival Decisions in Clinical Studies of Ceramic and Metal-Ceramic Fixed Dental Prostheses

    Science.gov (United States)

    Anusavice, Kenneth J.

    2011-01-01

    “Nothing worthwhile is ever without complications.”– Nora Roberts The recent increase in reports from clinical studies of ceramic chipping has raised the question of which criteria should constitute success or failure of total-ceramic prostheses. Terminology such as minor chipping[1], partial chipping, technical complications[2, 3], and biological complications have crept into the dental terminology and they have complicated our classification of success and failure of these crown and bridge restorations. Some journals have permitted the reporting of fractures as “complications” and they are not necessarily classified as failures in the study. One study has attempted to classify chipping fractures according to their severity and subsequent treatment.[4] This is a promising approach to resolve the challenges to the classification of chipping fracture. The term ‘chipping fracture’ is more descriptive than ‘chipping’ since the latter term tends to imply an event of minor consequence. Two types of statistics are reported routinely in these studies, i.e., percent success, which is a measure of restorations that survive without any adverse effects, and percent survival, which is a measure of all restorations that survive even though they may have exhibited chipping fracture or they may have been repaired. Why has this scenario occurred? One possible explanation is that many of these types of fractures are very small and do not affect function or esthetics. Another reason is that corporate sponsors prefer to use the term chipping since it does not connote failure in the sense that the term fracture does. In any event, we need to be more precise in our scientific observations of fracture and classifications of the various types of fracture including details on the location of fracture and the prosthesis design configuration. Because of the lack of standardized methods for describing chipping fractures, materials scientists are unable to properly analyze

  12. Standardizing failure, success, and survival decisions in clinical studies of ceramic and metal-ceramic fixed dental prostheses.

    Science.gov (United States)

    Anusavice, Kenneth J

    2012-01-01

    The recent increase in reports from clinical studies of ceramic chipping has raised the question of which criteria should constitute success or failure of total-ceramic prostheses. Terminologies such as minor chipping [1], partial chipping, technical complications [2,3], and biological complications have crept into the dental terminology and they have complicated our classification of success and failure of these crown and bridge restorations. Some journals have permitted the reporting of fractures as "complications" and they are not necessarily classified as failures in the study. One study has attempted to classify chipping fractures according to their severity and subsequent treatment [4]. This is a promising approach to resolve the challenges to the classification of chipping fracture. The term 'chipping fracture' is more descriptive than 'chipping' since the latter term tends to imply an event of minor consequence. Two types of statistics are reported routinely in these studies, i.e., percent success, which is a measure of restorations that survive without any adverse effects, and percent survival, which is a measure of all restorations that survive even though they may have exhibited chipping fracture or they may have been repaired. Why has this scenario occurred? One possible explanation is that many of these types of fractures are very small and do not affect function or esthetics. Another reason is that corporate sponsors prefer to use the term chipping since it does not connote failure in the sense that the term fracture does. In any event, we need to be more precise in our scientific observations of fracture and classifications of the various types of fracture including details on the location of fracture and the prosthesis design configuration. Because of the lack of standardized methods for describing chipping fractures, materials scientists are unable to properly analyze the effect of material properties and design factors on the time

  13. Fifteen-year survival of anterior all-ceramic cantilever resin-bonded fixed dental prostheses.

    Science.gov (United States)

    Kern, Matthias

    2017-01-01

    The aim of this follow-up study was to report the long-term outcome of all-ceramic cantilever resin-bonded fixed dental prostheses (RBFDPs). In 16 patients (mean age of 33.3±17.5years) 22 RBFDPs made from a glass-infiltrated alumina ceramic (In-Ceram) were inserted with a phosphate monomer containing luting agent after air-abrasion of the retainer wings. The abutment preparation included a shallow groove on the cingulum and a small proximal box. The restorations replacing 16 maxillary and 6 mandibular incisors were followed over a mean observation time of 188.7 months. No restoration debonded. Two RBFDPs fractured and were lost 48 and 214 months after insertion, respectively. The 10-year and 15-year survival rates were both 95.4% and dropped to 81.8% after 18 years. Anterior all-ceramic cantilever RBFDPs exhibited an excellent clinical longevity. Copyright © 2016 Elsevier Ltd. All rights reserved.

  14. Implant-supported prostheses versus conventional permanent and removable dentures

    Directory of Open Access Journals (Sweden)

    Koszuta Agnieszka

    2014-06-01

    Full Text Available Social, economic and technological progress results in an increasing range of treatment and rehabilitation methods for patients with partial or complete edentulism. The role of the dentist is to inform the patient about the full range of available missing teeth treatment options leading to complete rehabilitation of the masticatory organ in agreement with the patient’s aesthetic and functional expectations. The aim of the paper was to identify the type of prostheses used by patients before opting for implantsupported teeth replacements, according to the patients’ age, sex, marital status, place of residence and education. The study covered 464 patients, women and men, aged 20-74, treated with dental implants. The patients answered questions in an anonymous questionnaire. The influence of the prosthetic replacement type according to age and marital status was highly statistically significant, whereas it was statistically significant according to sex, place of residence and education. The female respondents who previously used tissue-borne complete or partial dentures opted for implant treatment more frequently. The respondents younger than 40 and between 40-60 years of age who did not previously used any prosthetic replacements opted for implant treatment more frequently. The respondents who did not use any prosthetic replacements decided to undergo implant treatment most frequently, regardless of their marital status, education and place of residence. The patients opted for implant treatment to improve their quality of life, despite the high cost of such therapy.

  15. Implant prostheses for convertibility, stress control, esthetics, and hygiene.

    Science.gov (United States)

    Garfield, R E

    1988-07-01

    A method of connecting "fixed partial denture" prostheses to osseointegrated implant fixtures has been described. The advantages of this system of restoration for partially and fully edentulous mouths are that it is more effective in addressing the problems of (1) stress-control on abutments, (2) a back-up system for abutment failures, (3) esthetics, and (4) control of bacterial plaques around abutments. To accomplish this procedure, the application of convertible periodontal prosthesis techniques with modifications to some existing implant systems is undertaken. The disadvantages of this method seem insignificant when one considers the complexities and risks involved with the present array of implant prosthesis alternatives. Some patients and dentists might consider the necessity of the prosthesis being detachable as one disadvantage. In reality, the prosthesis can be used as a fixed restoration until the patient has fully adapted to the new proprioception and appearance. A large percentage of patients feel uncomfortable with the word "removable" because it immediately creates a perception of unsightly metallic clasp display, palatal coverage, tongue interference, and negative body image. The use of the term "detachable" coupled with the doctor's offer to perform this task for the patient "whenever necessary" will usually relieve the patient's anxiety and allow the treatment to proceed. Once neuromuscular and esthetic adaptation have occurred and the patient has accepted the prosthesis, daily detaching and home-care hygiene by the patient will follow without incident. Esthetic improvement is obvious (Fig. 3).

  16. Are aortic endograft prostheses fully hemo-compatible? A dielectric spectroscopy investigation of the electrical alterations induced on erythrocyte cell membranes

    Energy Technology Data Exchange (ETDEWEB)

    Basoli, Antonio [Clinica Chirurgica II, Universita di Roma ' La Sapienza' , Rome (Italy); Bordi, Federico [Dipartimento di Fisica, Universita di Roma ' La Sapienza' , Rome (Italy); Cametti, Cesare [Dipartimento di Fisica, Universita di Roma ' La Sapienza' , Rome (Italy); Faraglia, Vittorio [Cattedra di Chirurgia Vascolare, Second School of Medicine, Universita di Roma ' La Sapienza' , Rome (Italy); Gili, Tommaso [Dipartimento di Fisica, Universita di Roma ' La Sapienza' , Rome (Italy); Rizzo, Luigi [Cattedra di Chirurgia Vascolare, Second School of Medicine, Universita di Roma ' La Sapienza' , Rome (Italy); Taurino, Maurizio [Cattedra di Chirurgia Vascolare, Second School of Medicine, Universita di Roma ' La Sapienza' , Rome (Italy)

    2007-03-01

    In this paper we present a new approach directed to ascertain the full hemo-compatibility of aortic endograft prostheses based on the measurement of the passive electrical parameters of the erythrocyte cell membrane. The red blood cell membrane, from an electric point of view, is characterized by an electrical permittivity, {epsilon}{sub s}, which takes into account the structural charged organization of the lipid double layer, and by the electrical conductivity, {sigma}{sub s}, which accounts for the ionic transport processes across the membrane. These parameters can be easily measured by means of a radiowave dielectric spectroscopy technique, analyzing the dependence of the electrical impedance of an erythrocyte suspension on the frequency of the applied electric field. In this preliminary report, we investigate the alterations induced, at a membrane level, by two different devices commonly employed for endovascular abdominal aortic aneurysm exclusion, i.e., Excluder (registered) and Zenith (registered) devices, implanted in ten patients. We observe, in all the cases investigated, a statistically significant increase of both the permittivity {epsilon}{sub s} and electrical conductivity {sigma}{sub s} of the erythrocyte membrane upon the prosthesis implant, this increase being higher than about 20% of the un-treated values. Moreover, these alterations remain roughly unaffected 30 days after surgery. These findings suggest that a complete hemo-compatibility of these prostheses is lacking, even if the observed alterations may not have a clinical relevance.

  17. VKORC1-1639G>A, CYP2C9, EPHX1691A>G genotype, body weight, and age are important predictors for warfarin maintenance doses in patients with mechanical heart valve prostheses in southwest China.

    Science.gov (United States)

    Gu, Qiang; Kong, Yan; Schneede, Jörn; Xiao, Ying-Bin; Chen, Lin; Zhong, Qian-Jin; Wang, Xue-Feng; Hao, Jia; Chen, Bai-Cheng; Chen, Jing-Jin

    2010-12-01

    To investigate the contribution of genetic polymorphisms of vitamin K epoxide reductase complex subunit 1 gene VKORC1-1639G>A, cytochrome P450 2C9 gene (CYP2C9), EPHXI, and clinical factors to warfarin sensitivity in southwest Chinese Han patients with mechanical heart valve prostheses. A total of 127 patients with mechanical heart valve prostheses who have been followed up at our department during the past 23 years were enrolled in this study and compared to a control group that consisted of 133 randomly selected healthy blood donors. These Chinese patients met stable warfarin dosage requirements and had reached the target international normalized ratio (INR) of 1.5-2.0. PCR and direct sequencing were carried out to identify the polymorphisms of VKORC1-1639G>A (rs9923231), CYP2C9*3 (rs1057910), CYP2C9 IVS3-65G>C (rs9332127), and EPHX1691A>G (rs4653436). In addition, total and free (non-protein-bound) warfarin concentrations were analyzed. There were great interindividual differences in warfarin maintenance dosage (ranging from 0.6 to 8.4 mg/day) among the 127 patients with mechanical heart valve prostheses. VKORC1-1639G>A, CYP2C9, EPHX1691A>G polymorphism, body weight, and age were found to affect the dose demands. Multiple linear regression models incorporating genetic polymorphisms of VKORC1, CYP2C9, EPHX1691A>G, and the nongenetic factors of age and body weight were developed, and explained up to 76.8% of the total variation (adjusted R (2) of 0.743) in warfarin maintenance doses in southwest Chinese patients with mechanical heart valve prostheses.

  18. SU-E-I-75: Evaluation of An Orthopedic Metal Artifact Reduction (O-MAR) Algorithm On Patients with Spinal Prostheses Near Spinal Tumors

    International Nuclear Information System (INIS)

    Shen, Z; Xia, P; Djemil, T; Klahr, P

    2014-01-01

    Purpose: To evaluate the impact of a commercial orthopedic metal artifact reduction (O-MAR) algorithm on CT image quality and dose calculation for patients with spinal prostheses near spinal tumors. Methods: A CT electron density phantom was scanned twice: with tissue-simulating inserts only, and with a titanium insert replacing solid water. A patient plan was mapped to the phantom images in two ways: with the titanium inside or outside of the spinal tumor. Pinnacle and Eclipse were used to evaluate the dosimetric effects of O-MAR on 12-bit and 16-bit CT data, respectively. CT images from five patients with spinal prostheses were reconstructed with and without O-MAR. Two observers assessed the image quality improvement from O-MAR. Both pencil beam and Monte Carlo dose calculation in iPlan were used for the patient study. The percentage differences between non-OMAR and O-MAR datasets were calculated for PTV-min, PTV-max, PTV-mean, PTV-V100, PTV-D90, OAR-V10Gy, OAR-max, and OAR-D0.1cc. Results: O-MAR improved image quality but did not significantly affect the dose distributions and DVHs for both 12-bit and 16- bit CT phantom data. All five patient cases demonstrated some degree of image quality improvement from O-MAR, ranging from small to large metal artifact reduction. For pencil beam, the largest discrepancy was observed for OARV-10Gy at 5.4%, while the other seven parameters were ≤0.6%. For Monte Carlo, the differences between non-O-MAR and O-MAR datasets were ≤3.0%. Conclusion: Both phantom and patient studies indicated that O-MAR can substantially reduce metal artifacts on CT images, allowing better visualization of the anatomical structures and metal objects. The dosimetric impact of O-MAR was insignificant regardless of the metal location, image bit-depth, and dose calculation algorithm. O-MAR corrected images are recommended for radiation treatment planning on patients with spinal prostheses because of the improved image quality and no need to modify

  19. Radionuclide arthrogram with SPECT/CT for the evaluation of mechanical loosening of hip and knee prostheses

    International Nuclear Information System (INIS)

    Chew, C.G.; Lewis, P.; Middleton, F.; Wijngaard, R. van den; Deshaies, A.

    2010-01-01

    The Objective of this study was to evaluate the value of single photon emission computed tomography (SPECT)/CT in radionuclide arthrogram (RNA) for the assessment of mechanical loosening of hip and knee prostheses. A retrospective audit of 117 RNA SPECT/CTs evaluated by a single reader- 40 hips, (1 hemiarthroplasty) and 77 knees (12 unicompartmental). The detection of any radiotracer within the bone/prosthetic interface was deemed positive for loosening. The operative assessment of 29 hip and 44 knee prosthetic joints was known and used as the gold standard. A subsequent blinded reassessment of the planar images was performed and compared with the SPECT/CT results for 26 of the 29 hip and 42 of the 44 knee prostheses. The respective SPECT/CT versus planar results were as follows: hips- acetabular cup: sensitivity: 73 versus 0%; specificity: 71 versus 100%; positive predictive value: 62% versus indeterminate; negative predictive value: 80% versus 72% (p=0.0044). Hips- femoral component: sensitivity: 78 versus 63%; specificity: 90 versus 94%; positive predictive value: 78 versus 83%; negative predictive value: 90 versus 85% (p=0.2482). Knees- femoral component: sensitivity: 75 versus 17%; specificity 63 versus 97%; positive predictive value: 43 versus 67%; negative predictive value: 87 versus 74% (p=0.0001). Knees- tibial component: sensitivity: 86 versus 63%; specificity: 86 versus 76%; positive predictive value: 55 versus 38%; negative predictive value: 97 versus 90% (p=0.6831). For evaluation of mechanical loosening of the hip prosthesis SPECT/CT was significantly better than planar scanning for the acetabular cup, but not for the femoral stem. For evaluation of the knee prosthesis, a significant improvement was noted using SPECT/CT for the femoral component, and although superior results were also noted for the tibial component, statistical significance was not reached. Taking into account the limitations of this retrospective audit, the value of using RNA SPECT

  20. Crossover study of amputee stair ascent and descent biomechanics using Genium and C-Leg prostheses with comparison to non-amputee control.

    Science.gov (United States)

    Lura, Derek J; Wernke, Matthew W; Carey, Stephanie L; Kahle, Jason T; Miro, Rebecca M; Highsmith, M Jason

    2017-10-01

    This study was a randomized crossover of stair ambulation of Transfemoral Amputees (TFAs) using the Genium and C-Leg prosthetic knees. TFAs typically have difficulty ascending and descending stairs, limiting community mobility. The objective of this study was to determine the relative efficacy of the Genium and C-Leg prostheses for stair ascent and descent, and their absolute efficacy relative to non-amputees. Twenty TFAs, and five non-amputees participated in the study. TFAs were randomized to begin the study with the Genium or C-Leg prosthesis. Informed consent was obtained from all participants prior to data collection and the study was listed on clinicaltrials.gov (#NCT01473662). After fitting, accommodation, and training, participants were asked to demonstrate their preferred gait pattern for stair ascent and descent and a step-over-step pattern if able. TFAs then switched prosthetic legs and repeated fitting, accommodation, training, and testing. An eight camera Vicon optical motion analysis system, and two AMTI force plates were used to track and analyze the participants' gait patterns, knee flexion angles, knee moment normalized by body weight, and swing time. For stair descent, no significant differences were found between prostheses. For stair ascent, Genium use resulted in: increased ability to use a step-over-step gait pattern (p=0.03), increased prosthetic side peak knee flexion (pstair ascent relative to the C-Leg, by enabling gait patterns that more closely resembled non-amputees. Copyright © 2017 Elsevier B.V. All rights reserved.

  1. Design of Complete Dentures by Adopting CAD Developed for Fixed Prostheses.

    Science.gov (United States)

    Li, Yanfeng; Han, Weili; Cao, Jing; Iv, Yuan; Zhang, Yue; Han, Yishi; Shen, Yi; Ma, Zheng; Liu, Huanyue

    2018-02-01

    The demand for complete dentures is expected to increase worldwide, but complete dentures are mainly designed and fabricated manually involving a broad series of clinical and laboratory procedures. Therefore, the quality of complete dentures largely depends on the skills of the dentist and technician, leading to difficulty in quality control. Computer-aided design and manufacturing (CAD/CAM) has been used to design and fabricate various dental restorations including dental inlays, veneers, crowns, partial crowns, and fixed partial dentures (FPDs). It has been envisioned that the application of CAD/CAM technology could reduce intensive clinical/laboratory work for the fabrication of complete dentures; however, CAD/CAM is seldom used to fabricate complete dentures due to the lack of suitable CAD software to design virtual complete dentures although the CAM techniques are in a much advanced stage. Here we report the successful design of virtual complete dentures using CAD software of 3Shape Dental System 2012, which was developed for designing fixed prostheses instead of complete dentures. Our results demonstrated that complete dentures could be successfully designed by the combination of two modeling processes, single coping and full anatomical FPD, available in the 3Shape Dental System 2012. © 2016 by the American College of Prosthodontists.

  2. The use of interlocking prostheses for both temporary and definitive management of infected periprosthetic femoral fractures.

    Science.gov (United States)

    Konan, Sujith; Rayan, Faizal; Manketelow, Andrew R J; Haddad, Fares S

    2011-12-01

    Infected periprosthetic fractures around total hip arthroplasties are an extremely challenging problem. We describe our experience of managing infected periprosthetic femoral fractures using interlocking long-stem femoral prostheses either as temporary functional spacers or as definitive implants. The Cannulock (Orthodesign, Christchurch, United Kingdom) uncoated stem was used in 12 cases, and the Kent hip prosthesis (Biomet Merck, Bridgend, United Kingdom), in 5 cases. Satisfactory outcome was noted in all cases, and in 11 cases, revision to a definitive stem has been undertaken after successful control of infection and fracture union. The use of interlocking stems offers a relatively appealing solution for a complex problem and avoids the complications that would be associated with resection of the entire femur or the use of large quantities of bone cement. Copyright © 2011 Elsevier Inc. All rights reserved.

  3. [Aftercare for durability and profitability of single-unit and multi-unit fixed dental prostheses].

    Science.gov (United States)

    de Baat, C; van Loveren, C; van der Maarel-Wierink, C D; Witter, D J; Creugers, N H J

    2013-01-01

    An important aim ofa treatment with single-unit and multi-unit fixed dental prostheses is a durable and profitable treatment outcome. That requires aftercare, too. First, the frequency of routine oral examinations should be assessed, using an individual risk profile. The objectives of the routine oral examinations are the prevention and, when necessary, the treatment of pathological conditions and complications. With regard to prevention, attention should be paid to information and instruction, oral biofilm and calculus, non-functional activities, hard tooth tissues, periodontal and peri-implant tissues, and saliva. Subsequently, it can be determined whether the intended durability and profitability have been achieved or can still be achieved, whether or not through indicated adjustments. Special attention should be paid to endodontically treated teeth. Restorative, repair or replacement treatments may be indicated in case ofcomplications, such as loose single- or multi-unitfixed dental prosthesis, fracture of a fixed dental prosthesis unit, lost tooth pulp vitality, tooth root fracture, and implant or implant abutment problems.

  4. Dentistry investigations of teeth and dental prostheses using OCT

    Science.gov (United States)

    Sinescu, C.; Duma, V.-F.; Canjau, S.; Dobre, G.; Demian, D.; Cernat, R.; Negrutiu, M. L.; Todea, C.; Topala, F. I.; Hutiu, Gh.; Bradu, A.; Podoleanu, A. G.

    2016-04-01

    We present some of our recent investigations in Dental Medicine using Optical Coherence Tomography (OCT). Time Domain (TD), Spectral Domain (SD), and Swept Source (SS) OCT in-house developed systems are being used, for both ex vivo and in vivo investigations in the oral cavity. We study ex vivo the interface between the tooth and the dental sealant and demonstrate the limitations of the X-rays investigations that are now the gold standard for such procedures. Using OCT, defects in the interface that cannot be identified in radiographs can be determined both as position and magnitude. The drilling process of teeth can also be characterized in real time using OCT, to monitor the remaining dentin thickness (RDT) in order to avoid opening the pulp chamber. We demonstrate in this respect that an RDT of 0.5 mm is the minimum value to assure the integrity of the dentin wall between the drilled cavity and the pulp chamber; at an RDT of 0.3 mm or less a fracture is initiated, the dentin is punctured and endodontic treatment must follow. In vivo OCT investigations in the oral cavity were also performed (i.e., for metalloceramic prostheses and for ceramic inlay tooth interfaces), with the low cost, light weight and versatile handheld probes with 1D galvoscanners that we have developed and applied for a range of in-house developed OCT systems, in various clinical applications. They are briefly discussed, as well as some of our current and future work in the field, including for studies of soft tissue in the mouth.

  5. Performance of zirconia ceramic cantilever fixed dental prostheses: 3-year results from a prospective, randomized, controlled pilot study.

    Science.gov (United States)

    Zenthöfer, Andreas; Ohlmann, Brigitte; Rammelsberg, Peter; Bömicke, Wolfgang

    2015-07-01

    Little is known about the clinical performance of ceramic cantilever fixed dental prostheses on natural teeth. The purpose of this randomized controlled pilot study was to evaluate the clinical performance of ceramic and metal ceramic cantilever fixed dental prostheses (CFDPs) after 3 years of service. Twenty-one participants were randomly allocated to 2 treatment groups. Participants in the ceramic (ZC) group (n=11) each received 1 CFDP made of yttria-stabilized, tetragonal zirconia polycrystal; the others (n=10) were fitted with a metal ceramic (MC) CFDP. All CFDPs were retained by 2 complete crown abutments and replaced 1 tooth. The clinical target variables were survival, incidence of complications, probing pocket depth (PPD), probing attachment level (PAL), plaque index (PI), gingival index (GI), and esthetic performance as rated by the participants. The United States Public Health Service (USPHS) criteria were used to evaluate chipping, retention, color, marginal integrity, and secondary caries. Descriptive statistics and nonparametric analyses were applied to the target variables in the 2 groups. The esthetic performance of the CFDPs was also visualized by using a pyramid comparison. The overall survival of the CFDPs was 100% in both groups. During the 3-year study, 6 clinically relevant complications requiring aftercare were observed among 5 participants (4 in the ZC group and 2 in the MC group). Changes in the PI, GI, PPD, and PAL of the abutment teeth were similar for both groups (P>.05). The participants regarded the esthetic performance of ZC-CFDPs and MC-CFDPs as satisfactory. Within the 3-year observation period, the clinical performance of MC-FDPs and ZC-FDPs was acceptable. More extensive research with larger sample sizes is encouraged, however, to confirm the evaluation of the survival of Y-TZP hand-veneered cantilever FPDs. Copyright © 2015 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.

  6. Prostheses size dependency of the mechanical response of the herniated human abdomen.

    Science.gov (United States)

    Simón-Allué, R; Hernández-Gascón, B; Lèoty, L; Bellón, J M; Peña, E; Calvo, B

    2016-12-01

    Hernia repairs still exhibit clinical complications, i.e. recurrence, discomfort and pain and mesh features are thought to be highly influent. The aim of this study is to evaluate the impact of the defect size and mesh type in an herniated abdominal wall using numerical models. To do so, we have started from a FE model based on a real human abdomen geometry obtained by MRI, where we have provoked an incisional hernia of three different sizes. The surgical procedure was simulated by covering the hernia with a prostheses, and three surgical meshes with distinct mechanical properties were used for the hernia repair: an isotropic heavy-weight mesh (Surgipro @ ), a slightly anisotropic light-weight mesh (Optilene @ ) and a highly anisotropic medium-weight mesh (Infinit @ ). The mechanical response of the wall to a high intraabdominal pressure (corresponding to a coughing motion) was analyzed here. Our findings suggest that the anisotropy of the mesh becomes more relevant with the increase of the defect size. Additionally, according to our results Optilene @ showed the closest deformation to the natural distensibility of the abdomen while Infinit @ should be carefully used due to its excessive compliance.

  7. The accuracy of the CAD system using intraoral and extraoral scanners for designing of fixed dental prostheses.

    Science.gov (United States)

    Shimizu, Sakura; Shinya, Akikazu; Kuroda, Soichi; Gomi, Harunori

    2017-07-26

    The accuracy of prostheses affects clinical success and is, in turn, affected by the accuracy of the scanner and CAD programs. Thus, their accuracy is important. The first aim of this study was to evaluate the accuracy of an intraoral scanner with active triangulation (Cerec Omnicam), an intraoral scanner with a confocal laser (3Shape Trios), and an extraoral scanner with active triangulation (D810). The second aim of this study was to compare the accuracy of the digital crowns designed with two different scanner/CAD combinations. The accuracy of the intraoral scanners and extraoral scanner was clinically acceptable. Marginal and internal fit of the digital crowns fabricated using the intraoral scanner and CAD programs were inferior to those fabricated using the extraoral scanner and CAD programs.

  8. Intraocular camera for retinal prostheses: Refractive and diffractive lens systems

    Science.gov (United States)

    Hauer, Michelle Christine

    The focus of this thesis is on the design and analysis of refractive, diffractive, and hybrid refractive/diffractive lens systems for a miniaturized camera that can be surgically implanted in the crystalline lens sac and is designed to work in conjunction with current and future generation retinal prostheses. The development of such an intraocular camera (IOC) would eliminate the need for an external head-mounted or eyeglass-mounted camera. Placing the camera inside the eye would allow subjects to use their natural eye movements for foveation (attention) instead of more cumbersome head tracking, would notably aid in personal navigation and mobility, and would also be significantly more psychologically appealing from the standpoint of personal appearances. The capability for accommodation with no moving parts or feedback control is incorporated by employing camera designs that exhibit nearly infinite depth of field. Such an ultracompact optical imaging system requires a unique combination of refractive and diffractive optical elements and relaxed system constraints derived from human psychophysics. This configuration necessitates an extremely compact, short focal-length lens system with an f-number close to unity. Initially, these constraints appear highly aggressive from an optical design perspective. However, after careful analysis of the unique imaging requirements of a camera intended to work in conjunction with the relatively low pixellation levels of a retinal microstimulator array, it becomes clear that such a design is not only feasible, but could possibly be implemented with a single lens system.

  9. Using a colorimeter to develop an intrinsic silicone shade guide for facial prostheses.

    Science.gov (United States)

    Over, L M; Andres, C J; Moore, B K; Goodacre, C J; Muñoz, C A

    1998-12-01

    To determine if using CIE L*a*b* color measurements of white facial skin could be correlated to those of silicone shade samples that visually matched the skin. Secondly, to see if a correlation in color measurements could be achieved between the silicone shade samples and duplicated silicone samples made using a shade-guide color formula. A color booth was designed according to ASTM specifications, and painted using a Munsell Value 8 gray. A Minolta colorimeter was used to make facial skin measurements on 15 white adults. The skin color was duplicated using custom-shaded silicone samples. A 7-step wedge silicone shade guide was then fabricated, representing the commonly encountered thicknesses when fabricating facial prostheses. The silicone samples were then measured with the Minolta colorimeter. The readings were compared with the previous L*a*b* readings from the corresponding patient's skin measurements, and the relative color difference was then calculated. Silicone samples were fabricated and analyzed for three of the patients to determine if duplication of the visually matched silicone specimen was possible using the silicone color formula, and if the duplicates were visually and colorimetrically equivalent to each other. The color difference Delta E and chromaticity was calculated, and the data were analyzed using a coefficient-of-variation formula expressed by percent. A Pearson Product Moment Correlation Coefficient was performed to determine if a correlation existed between the skin and the silicone samples at the p 0), but only the 1-mm and 4-mm b* readings were very strong. Patient and silicone L*a*b* measurement results showed very little change in the a* axis, while the L* and b* measurements showed more change in their numbers, with changes in depth for all patient silicone samples. Delta E numbers indicated the lowest Delta E at the 1-mm depth and the highest Delta E at the 10-mm depth. All duplicated samples matched their original silicone samples

  10. Time course of fibronectin in the peri-implant tissue and neointima formation after functional implantation of polyester-based vascular prostheses with different porosity in pigs

    Energy Technology Data Exchange (ETDEWEB)

    Patrzyk, Maciej; Hoene, Andreas [Department of Surgery, Ernst Moritz Arndt University Greifswald, Friedrich-Loeffler-Str. 23, D-17489 Greifswald (Germany); Jarchow, Raymond [Computation Centre, Ernst Moritz Arndt University Greifswald, Felix-Hausdorff-Str. 12, D-17489 Greifswald (Germany); Wilhelm, Lutz [Department of Surgery, Hospital Demmin, Loitzer Str. 1, D-17109 Demmin (Germany); Walschus, Uwe; Schlosser, Michael [Research Group of Predictive Diagnostics of the Department of Medical Biochemistry and Molecular Biology and Institute of Pathophysiology, Ernst Moritz Arndt University Greifswald, Greifswalder Str. 11c, D-17495 Karlsburg (Germany); Zippel, Roland, E-mail: schlosse@uni-greifswald.d [Department of Surgery, Elbland Hospital Center, Weinbergstr. 8, D-01589 Riesa (Germany)

    2010-10-01

    Intima hyperplasia, resulting from extracellular matrix (ECM) secretion, can lead to vascular prosthesis occlusion and is a major problem in vascular surgery. Fibronectin might contribute to ongoing ECM secretion. However, the exact role of fibronectin and its influence on neointima formation remains unclear. This study was aimed at investigating the time course of the fibronectin area fraction and neointima formation following the functional implantation of three different polyester vascular prostheses into pigs. The infrarenal aorta from 15 animals (n = 5/group) was replaced by prosthesis segments with low, medium and high primary porosity. After 7, 14, 21, 28 and 116 days, the prostheses were morphometrically examined. Overall, the fibronectin area fraction was inversely correlated with the neointima thickness, demonstrating high fibronectin levels in the early phase (days 7 and 14) and low levels in the later phase with almost complete neointima formation (days 21-116). Throughout the study, fibronectin levels were highest at the proximal anastomosis region. The low porosity prosthesis had the highest fibronectin area fraction and a delayed neointima formation in the middle phase (days 21 and 28) but the highest neointima lining on day 116. The results indicate a relationship between fibronectin and neointima formation with the prosthesis porosity, demonstrating the importance of the textile design for tissue reactions following implantation.

  11. Designing and testing lightweight shoulder prostheses with hybrid actuators for movements involved in typical activities of daily living and impact absorption.

    Science.gov (United States)

    Sekine, Masashi; Kita, Kahori; Yu, Wenwei

    2015-01-01

    Unlike forearm amputees, transhumeral amputees have residual stumps that are too small to provide a sufficient range of operation for their prosthetic parts to perform usual activities of daily living. Furthermore, it is difficult for small residual stumps to provide sufficient impact absorption for safe manipulation in daily living, as intact arms do. Therefore, substitution of upper limb function in transhumeral amputees requires a sufficient range of motion and sufficient viscoelasticity for shoulder prostheses under critical weight and dimension constraints. We propose the use of two different types of actuators, ie, pneumatic elastic actuators (PEAs) and servo motors. PEAs offer high power-to-weight performance and have intrinsic viscoelasticity in comparison with motors or standard industrial pneumatic cylinder actuators. However, the usefulness of PEAs in large working spaces is limited because of their short strokes. Servo motors, in contrast, can be used to achieve large ranges of motion. In this study, the relationship between the force and stroke of PEAs was investigated. The impact absorption of both types of actuators was measured using a single degree-of-freedom prototype to evaluate actuator compliance for safety purposes. Based on the fundamental properties of the actuators identified, a four degree-of-freedom robotic arm is proposed for prosthetic use. The configuration of the actuators and functional parts was designed to achieve a specified range of motion and torque calculated from the results of a simulation of typical movements performed in usual activities of daily living. Our experimental results showed that the requirements for the shoulder prostheses could be satisfied.

  12. Considerations for services from dental technicians in fabrication of fixed prostheses: A survey of commercial dental laboratories in Thessaloniki, Greece.

    Science.gov (United States)

    Hatzikyriakos, Andreas; Petridis, Haralampos P; Tsiggos, Nikolaos; Sakelariou, Sotirios

    2006-11-01

    Effective communication and cooperation between dentists and dental technicians are essential in providing quality services. There has been a lack of information regarding dentist-dental technician communications and current methods and materials used for the fabrication of fixed partial dentures (FPDs). This cross-sectional study identified the materials and techniques used for fabrication of FPDs, as well as the status of communication between dentists and dental technicians in Thessaloniki, Greece. A questionnaire was developed with 7 sections pertaining to procedures and materials used for the fabrication of fixed prostheses: general questions, infection control, impressions/interocclusal records, die technique/mounting, information from final casts, prostheses design/materials, and communication/shade selection. The questionnaire was anonymous and distributed by the Association of Dental Technicians of Thessaloniki to all member laboratories (228) in the wider province of Thessaloniki, Greece. Due to the absence of normal distribution of the results, frequencies and medians were reported. Ninety-six of 228 dental laboratories responded (42.1% response rate). Twenty-six percent of dental laboratories did not routinely disinfect incoming items. The dental technicians considered 30% of incoming final impressions and 20% of interocclusal registrations as inadequate. Half of the time (55%) final casts were mounted by technicians on simple hinge articulators. Only 20% of tooth preparations had adequate finish lines. The majority (70%) of fixed restorations were metal-ceramic. Fifty-seven percent of dental technicians considered the delivery time requested by dentists as insufficient. The information provided in this study indicates areas of weakness in communication between dentists and dental technicians, along with areas where both parties should use greater care during clinical and laboratory procedures.

  13. Mastication and jaw motion of partially edentulous patients are affected by different implant-based prostheses.

    Science.gov (United States)

    Gonçalves, T M S V; Campos, C H; Rodrigues Garcia, R C M

    2014-07-01

    The main goal of prosthetic treatment is to restore masticatory function. However, insufficient evidence supports the recommendation of one specific prosthetic intervention for partially edentulous patients. Function after the use of three different prostheses by the same partially edentulous subject. Mastication was assessed in 12 subjects (mean age 62.6 ± 7.8 years) after they had used removable partial dentures (RPDs), implant-supported partial dentures (IRPDs) and implant-fixed partial dentures (IFPDs). Masticatory ability (MA) was estimated by visual analogue scale questionnaire, while the mandibular chewing motion was evaluated by kinesiographic device, representing an objective measurement of masticatory function. Data were analysed by repeated-measures anova followed by Tukey-Kramer (P < 0.05). MA improved after IRPD and IFPD use (P < 0.05). Opening, closing and total cycle time duration were reduced after both IRPD and IFPD use (P < 0.05), irrespectively the implant prosthesis type. IFPDs and IRPDs restore the masticatory function of partially edentulous patients better than RPDs. © 2014 John Wiley & Sons Ltd.

  14. Temperature measurement and control system for transtibial prostheses: Single subject clinical evaluation.

    Science.gov (United States)

    Ghoseiri, Kamiar; Zheng, Yong Ping; Leung, Aaron K L; Rahgozar, Mehdi; Aminian, Gholamreza; Masoumi, Mehdi; Safari, Mohammad Reza

    2018-01-01

    The snug fit of a prosthetic socket over the residual limb can disturb thermal balance and put skin integrity in jeopardy by providing an unpleasant and infectious environment. The prototype of a temperature measurement and control (TM&C) system was previously introduced to resolve thermal problems related to prostheses. This study evaluates its clinical application in a setting with reversal, single subject design. The TM&C system was installed on a fabricated prosthetic socket of a man with unilateral transtibial amputation. Skin temperature of the residual limb without prosthesis at baseline and with prosthesis during rest and walking was evaluated. The thermal sense and thermal comfort of the participant were also evaluated. The results showed different skin temperature around the residual limb with a temperature decrease tendency from proximal to distal. The TM&C system decreased skin temperature rise after prosthesis wearing. The same situation occurred during walking, but the thermal power of the TM&C system was insufficient to overcome heat build-up in some regions of the residual limb. The participant reported no significant change of thermal sense and thermal comfort. Further investigations are warranted to examine thermography pattern of the residual limb, thermal sense, and thermal comfort in people with amputation.

  15. Additive Manufacturing: A Comparative Analysis of Dimensional Accuracy and Skin Texture Reproduction of Auricular Prostheses Replicas.

    Science.gov (United States)

    Unkovskiy, Alexey; Spintzyk, Sebastian; Axmann, Detlef; Engel, Eva-Maria; Weber, Heiner; Huettig, Fabian

    2017-11-10

    The use of computer-aided design/computer-aided manufacturing (CAD/CAM) and additive manufacturing in maxillofacial prosthetics has been widely acknowledged. Rapid prototyping can be considered for manufacturing of auricular prostheses. Therefore, so-called prostheses replicas can be fabricated by digital means. The objective of this study was to identify a superior additive manufacturing method to fabricate auricular prosthesis replicas (APRs) within a digital workflow. Auricles of 23 healthy subjects (mean age of 37.8 years) were measured in vivo with respect to an anthropometrical protocol. Landmarks were volumized with fiducial balls for 3D scanning using a handheld structured light scanner. The 3D CAD dataset was postprocessed, and the same anthropometrical measurements were made in the CAD software with the digital lineal. Each CAD dataset was materialized using fused deposition modeling (FDM), selective laser sintering (SLS), and stereolithography (SL), constituting 53 APR samples. All distances between the landmarks were measured on the APRs. After the determination of the measurement error within the five data groups (in vivo, CAD, FDM, SLS, and SL), the mean values were compared using matched pairs method. To this, the in vivo and CAD dataset were set as references. Finally, the surface structure of the APRs was qualitatively evaluated with stereomicroscopy and profilometry to ascertain the level of skin detail reproduction. The anthropometrical approach showed drawbacks in measuring the protrusion of the ear's helix. The measurement error within all groups of measurements was calculated between 0.20 and 0.28 mm, implying a high reproducibility. The lowest mean differences of 53 produced APRs were found in FDM (0.43%) followed by SLS (0.54%) and SL (0.59%)--compared to in vivo, and again in FDM (0.20%) followed by SL (0.36%) and SLS (0.39%)--compared to CAD. None of these values exceed the threshold of clinical relevance (1.5%); however, the qualitative

  16. Microscopical analysis of synovial fluid wear debris from failing CoCr hip prostheses

    Science.gov (United States)

    Ward, M. B.; Brown, A. P.; Cox, A.; Curry, A.; Denton, J.

    2010-07-01

    Metal on metal hip joint prostheses are now commonly implanted in patients with hip problems. Although hip replacements largely go ahead problem free, some complications can arise such as infection immediately after surgery and aseptic necrosis caused by vascular complications due to surgery. A recent observation that has been made at Manchester is that some Cobalt Chromium (CoCr) implants are causing chronic pain, with the source being as yet unidentified. This form of replacement failure is independent of surgeon or hospital and so some underlying body/implant interface process is thought to be the problem. When the synovial fluid from a failed joint is examined particles of metal (wear debris) can be found. Transmission Electron Microscopy (TEM) has been used to look at fixed and sectioned samples of the synovial fluid and this has identified fine (< 100 nm) metal and metal oxide particles within the fluid. TEM EDX and Electron Energy Loss Spectroscopy (EELS) have been employed to examine the composition of the particles, showing them to be chromium rich. This gives rise to concern that the failure mechanism may be associated with the debris.

  17. Simulating auditory and visual sensorineural prostheses: a comparative review

    Science.gov (United States)

    Hallum, L. E.; Dagnelie, G.; Suaning, G. J.; Lovell, N. H.

    2007-03-01

    Microelectronic vision prosthesis proposes to render luminous spots (so-called phosphenes) in the visual field of the otherwise blind subject by way of an implanted array of stimulating electrodes, and in doing so restore some spatial vision. There are now many research teams worldwide working towards a therapeutic device, analogous to the cochlear implant, for the profoundly blind. Despite the similarities between the cochlear implant and vision prostheses, there are few instances in the literature where the two approaches are compared and contrasted with a mind to informing the science and engineering of the latter. This is the focus of the present review; specifically, our interest is psychophysics and signal processing. Firstly, we examine the cochlear implant, and review a handful of psychophysical work: the acoustic simulation of cochlear implants and the method used. We focus on the use of normally hearing subjects (played coloured noise bands or sine waves) as a means of investigating cochlear-implant efficacy and speech processing algorithms. These results provide guidance to vision researchers, for they address the interpretation of simulation data, and flag key areas, such as 'artificial' perception in the presence of noise, that require experimental work in coming years. Secondly, we provide an up-to-date review of the body of analogous psychophysical work: the visual simulation, involving normal observers, of microelectronic vision prosthesis. These simulations allow predictions as to the likely clinical efficacy of the prosthesis; indeed, results to date suggest that a number on the order of 100 implanted electrodes will afford subjects mobility and recognition of faces (and other complex stimuli), while even fewer electrodes facilitate reading printed text and very simple visuomanual tasks. Further, the simulations allow investigations of image and signal processing strategies, plus they provide researchers in the field, and other interested persons

  18. Biomechanical evaluation of the natural abutment teeth in combined tooth-implant-supported telescopic prostheses: a three-dimensional finite element analysis.

    Science.gov (United States)

    Chen, Yu; Wang, Chao; Huang, Yuanding; Feng, Tianming; Zou, Huawei; Fan, Yubo

    2017-07-01

    Telescopic overdentures supported by the combination of natural teeth and implants have been thought a valuable treatment for the severely compromised partially edentulous patients. But the combination of teeth and implants involves highly complex biomechanical problems. This study is to evaluate biomechanical behaviors of the natural abutment teeth with the treatment of combined tooth-implant supported telescopic crown prostheses in mandible through 3D FEA. According to this study, the prosthetic option supported by a combination of teeth and implants and retained by double crowns could protect teeth and their periodontal support tissues acting as a rigid splint, and may be a valuable treatment option for partially edentulous patients with severely reduced remaining teeth in mandible.

  19. The Poly Implant Prothèse breast prostheses scandal: Embodied risk and social suffering.

    Science.gov (United States)

    Greco, Cinzia

    2015-12-01

    This article examines the 2010 scandal surrounding the use and subsequent recall of adulterated Poly Implant Prothèse (PIP) silicone breast prostheses in France. It uses a mixed method approach that includes 12 interviews with French PIP prosthesis recipients, analyses of medical literature, policy documents of French and EU regulatory agencies, and an online forum for PIP recipients. These data are used to explain how the definition of "acceptable risk" in the silicone implants controversy of the 1990s in the US influenced the PIP scandal later on in France. Additionally, PIP recipients had an embodied experience of risk that clashed with the definition of risk used by authorities and some surgeons. The coverage of re-implantation was also defined at different policy levels, leading to variation in patients' suffering. The combination of fraud and lack of recognition from part of the medical system constitutes an example of social suffering for the patients involved. The PIP scandal is a useful case for analyzing the interconnection of embodied experience and professional and public policy definitions of medical risk through the concepts of moral economy and biological citizenship. Copyright © 2015 Elsevier Ltd. All rights reserved.

  20. Post-operative hemimaxillectomy rehabilitation using prostheses supported by zygoma implants and remaining natural teeth

    Directory of Open Access Journals (Sweden)

    Xing Zhou Qu

    Full Text Available OBJECTIVES: This study aimed to evaluate the stability of prostheses supported by zygoma implants and remaining teeth for subjects who had undergone hemi-maxillectomy. METHODS: Ten patients were included in the study. Oral rehabilitation was performed using a temporary prosthesis that was supported by remaining teeth for the first three months. Then, a zygoma implant was placed to provide support for a final prosthesis in addition to the remaining teeth. Each prosthesis was tailor-made according to biomechanical three-dimensional finite element analysis results. The patients were assessed using the prosthesis functioning scale of the Memorial Sloan-Kettering Cancer Center. In addition, retention and bite force were recorded for both the temporary prosthesis and the final prosthesis. RESULTS: The mean bite force of the prosthetic first molar was increased to 69.2 N. The mean retentive force increased to 13.5 N after zygoma implant insertion. The bite force on the prosthetic first molar was improved to 229.3 N. CONCLUSION: Bite force increased significantly with the support of a zygoma implant. The use of zygoma implants in the restoration of maxillary defects improved functional outcome and patient satisfaction.

  1. Designing and testing lightweight shoulder prostheses with hybrid actuators for movements involved in typical activities of daily living and impact absorption

    Directory of Open Access Journals (Sweden)

    Sekine M

    2015-07-01

    Full Text Available Masashi Sekine,1,2 Kahori Kita,1 Wenwei Yu1 1Center for Frontier Medical Engineering, 2Graduate School of Engineering, Chiba University, Chiba, Japan Abstract: Unlike forearm amputees, transhumeral amputees have residual stumps that are too small to provide a sufficient range of operation for their prosthetic parts to perform usual activities of daily living. Furthermore, it is difficult for small residual stumps to provide sufficient impact absorption for safe manipulation in daily living, as intact arms do. Therefore, substitution of upper limb function in transhumeral amputees requires a sufficient range of motion and sufficient viscoelasticity for shoulder prostheses under critical weight and dimension constraints. We propose the use of two different types of actuators, ie, pneumatic elastic actuators (PEAs and servo motors. PEAs offer high power-to-weight performance and have intrinsic viscoelasticity in comparison with motors or standard industrial pneumatic cylinder actuators. However, the usefulness of PEAs in large working spaces is limited because of their short strokes. Servo motors, in contrast, can be used to achieve large ranges of motion. In this study, the relationship between the force and stroke of PEAs was investigated. The impact absorption of both types of actuators was measured using a single degree-of-freedom prototype to evaluate actuator compliance for safety purposes. Based on the fundamental properties of the actuators identified, a four degree-of-freedom robotic arm is proposed for prosthetic use. The configuration of the actuators and functional parts was designed to achieve a specified range of motion and torque calculated from the results of a simulation of typical movements performed in usual activities of daily living. Our experimental results showed that the requirements for the shoulder prostheses could be satisfied. Keywords: shoulder prosthesis, hybrid actuation, pneumatic elastic actuator, antagonistic

  2. Randomized clinical trial of implant-supported ceramic-ceramic and metal-ceramic fixed dental prostheses: preliminary results.

    Science.gov (United States)

    Esquivel-Upshaw, Josephine F; Clark, Arthur E; Shuster, Jonathan J; Anusavice, Kenneth J

    2014-02-01

    The aim of this study was to determine the survival rates over time of implant-supported ceramic-ceramic and metal-ceramic prostheses as a function of core-veneer thickness ratio, gingival connector embrasure design, and connector height. An IRB-approved, randomized, controlled clinical trial was conducted as a single-blind pilot study involving 55 patients missing three teeth in either one or two posterior areas. These patients (34 women; 21 men; age range 52-75 years) were recruited for the study to receive a three-unit implant-supported fixed dental prosthesis (FDP). Two implants were placed for each of the 72 FDPs in the study. The implants (Osseospeed, Astra Tech), which were made of titanium, were grit blasted. A gold-shaded, custom-milled titanium abutment (Atlantis, Astra Tech), was secured to each implant body. Each of the 72 FDPs in 55 patients were randomly assigned based on one of the following options: (1) A. ceramic-ceramic (Yttria-stabilized zirconia core, pressable fluorapatite glass-ceramic, IPS e.max ZirCAD, and ZirPress, Ivoclar Vivadent) B. metal-ceramic (palladium-based noble alloy, Capricorn, Ivoclar Vivadent, with press-on leucite-reinforced glass-ceramic veneer, IPS InLine POM, Ivoclar Vivadent); (2) occlusal veneer thickness (0.5, 1.0, and 1.5 mm); (3) curvature of gingival embrasure (0.25, 0.5, and 0.75 mm diameter); and (4) connector height (3, 4, and 5 mm). FDPs were fabricated and cemented with dual-cure resin cement (RelyX, Universal Cement, 3M ESPE). Patients were recalled at 6 months, 1 year, and 2 years. FDPs were examined for cracks, fracture, and general surface quality. Recall exams of 72 prostheses revealed 10 chipping fractures. No fractures occurred within the connector or embrasure areas. Two-sided Fisher's exact tests showed no significant correlation between fractures and type of material system (p = 0.51), veneer thickness (p = 0.75), radius of curvature of gingival embrasure (p = 0.68), and connector height (p = 0

  3. Characterization of interfacial socket pressure in transhumeral prostheses: A case series.

    Science.gov (United States)

    Schofield, Jonathon S; Schoepp, Katherine R; Williams, Heather E; Carey, Jason P; Marasco, Paul D; Hebert, Jacqueline S

    2017-01-01

    One of the most important factors in successful upper limb prostheses is the socket design. Sockets must be individually fabricated to arrive at a geometry that suits the user's morphology and appropriately distributes the pressures associated with prosthetic use across the residual limb. In higher levels of amputation, such as transhumeral, this challenge is amplified as prosthetic weight and the physical demands placed on the residual limb are heightened. Yet, in the upper limb, socket fabrication is largely driven by heuristic practices. An analytical understanding of the interactions between the socket and residual limb is absent in literature. This work describes techniques, adapted from lower limb prosthetic research, to empirically characterize the pressure distribution occurring between the residual limb and well-fit transhumeral prosthetic sockets. A case series analyzing the result of four participants with transhumeral amputation is presented. A Tekscan VersaTek pressure measurement system and FaroArm Edge coordinate measurement machine were employed to capture socket-residual limb interface pressures and geometrically register these values to the anatomy of participants. Participants performed two static poses with their prosthesis under two separate loading conditions. Surface pressure maps were constructed from the data, highlighting pressure distribution patterns, anatomical locations bearing maximum pressure, and the relative pressure magnitudes. Pressure distribution patterns demonstrated unique characteristics across the four participants that could be traced to individual socket design considerations. This work presents a technique that implements commercially available tools to quantitatively characterize upper limb socket-residual limb interactions. This is a fundamental first step toward improved socket designs developed through informed, analytically-based design tools.

  4. Post-Cam Design and Contact Stress on Tibial Posts in Posterior-Stabilized Total Knee Prostheses: Comparison Between a Rounded and a Squared Design.

    Science.gov (United States)

    Watanabe, Toshifumi; Koga, Hideyuki; Horie, Masafumi; Katagiri, Hiroki; Sekiya, Ichiro; Muneta, Takeshi

    2017-12-01

    The post-cam mechanism in posterior stabilized (PS) prostheses plays an important role in total knee arthroplasty (TKA). The purpose of this study is to clarify the difference of the contact stress on the tibial post between a rounded post-cam design and a squared design during deep knee flexion and at hyperextension using the three-dimensional (3D) finite element models. We created 2 types of 3D, finite element models of PS prostheses (types A and B), whose surfaces were identical except for the post-cam geometries: type A has a rounded post-cam design, while type B has a squared design. Both types have a similar curved-shape intercondylar notch of the femoral component. Stress distributions, peak contact stresses, and contact areas on the tibial posts at 90°, 120°, and 150° flexion with/without 10° tibial internal rotation and at 10° hyperextension were compared between the 2 models. Type B demonstrated more concentrated stress distribution compared to type A. The peak contact stresses were similar in both groups during neutral flexion; however, the stresses were much higher in type B during flexion with 10° rotation and at hyperextension. The higher peak contact stresses corresponded to the smaller contact areas in the tibial post. A rounded post-cam design demonstrated less stress concentration during flexion with rotation and at hyperextension compared with a squared design. The results would be useful for development of implant designs and prediction of the contact stress on the tibial post in PS total knee arthroplasty. Copyright © 2017 Elsevier Inc. All rights reserved.

  5. Context-dependent adaptation improves robustness of myoelectric control for upper-limb prostheses

    Science.gov (United States)

    Patel, Gauravkumar K.; Hahne, Janne M.; Castellini, Claudio; Farina, Dario; Dosen, Strahinja

    2017-10-01

    Objective. Dexterous upper-limb prostheses are available today to restore grasping, but an effective and reliable feed-forward control is still missing. The aim of this work was to improve the robustness and reliability of myoelectric control by using context information from sensors embedded within the prosthesis. Approach. We developed a context-driven myoelectric control scheme (cxMYO) that incorporates the inference of context information from proprioception (inertial measurement unit) and exteroception (force and grip aperture) sensors to modulate the outputs of myoelectric control. Further, a realistic evaluation of the cxMYO was performed online in able-bodied subjects using three functional tasks, during which the cxMYO was compared to a purely machine-learning-based myoelectric control (MYO). Main results. The results demonstrated that utilizing context information decreased the number of unwanted commands, improving the performance (success rate and dropped objects) in all three functional tasks. Specifically, the median number of objects dropped per round with cxMYO was zero in all three tasks and a significant increase in the number of successful transfers was seen in two out of three functional tasks. Additionally, the subjects reported better user experience. Significance. This is the first online evaluation of a method integrating information from multiple on-board prosthesis sensors to modulate the output of a machine-learning-based myoelectric controller. The proposed scheme is general and presents a simple, non-invasive and cost-effective approach for improving the robustness of myoelectric control.

  6. Study of the effect of the silver content on the structural and mechanical behavior of Ag–ZrCN coatings for orthopedic prostheses

    Energy Technology Data Exchange (ETDEWEB)

    Ferreri, I., E-mail: isabelferreri@gmail.com [GRF-CFUM, University of Minho, Campus of Azurém, 4800-058 Guimarães (Portugal); CEB, Centre for Biological Engineering, University of Minho, Campus of Gualtar, 4700-057 (Portugal); Lopes, V. [GRF-CFUM, University of Minho, Campus of Azurém, 4800-058 Guimarães (Portugal); Calderon V, S. [GRF-CFUM, University of Minho, Campus of Azurém, 4800-058 Guimarães (Portugal); SEG-CEMUC, Mechanical Engineering Department, University of Coimbra, 3030-788 Coimbra (Portugal); Tavares, C.J. [GRF-CFUM, University of Minho, Campus of Azurém, 4800-058 Guimarães (Portugal); Cavaleiro, A. [SEG-CEMUC, Mechanical Engineering Department, University of Coimbra, 3030-788 Coimbra (Portugal); Carvalho, S. [GRF-CFUM, University of Minho, Campus of Azurém, 4800-058 Guimarães (Portugal); SEG-CEMUC, Mechanical Engineering Department, University of Coimbra, 3030-788 Coimbra (Portugal)

    2014-09-01

    With the increase of elderly population and health problems that are arising nowadays, hip joint prostheses are being widely used. However, it is estimated that 20% of hip replacement surgeries simply fails after few years, mainly due to wear fatigue. Bearing this in mind, this work reports on the development of new coatings that are able to sustain long and innocuous life inside the patient, which will confer to the usual biomaterials improved physical, mechanical and tribological properties. In particular, the development of multifunctional coatings based on Ag-ZrCN, prepared by DC reactive magnetron sputtering using two targets, Zr and a modified Zr target, in an Ar + C{sub 2}H{sub 2} + N{sub 2} atmosphere. Silver pellets were placed in the erosion area of the alloyed Zr target in order to obtain a silver content up to 8 at.%. The structural results obtained by x-ray diffraction show that the coatings crystallize in a NaCl crystal structure typical of ZrC{sub 1-x}N{sub x}. The increase of Ag content promoted the formation of an additional a-CN{sub x} amorphous phase, besides a silver crystalline phase. Hardness is decreasing, as increasing silver content. Despite the low thicknesses, adhesion values (L{sub C3}) can be considered as good. Dynamic fatigue results suggest that these coatings system can be a real asset in terms of mechanical properties, by improving the performance of usual Stainless Steel 316 L biomaterials. - Highlights: • ZrCN, silver and carbon based amorphous phases, form the structure of the coatings. • Ag–ZrCN coatings have a high capacity to withstand an impact load without fracturing. • Silver incorporation reduces the fatigue failures of the coatings. • The films possess mechanical resistance and biocompatibility, required in prostheses.

  7. Prognosis of Combining Remaining Teeth and Implants in Double-Crown-Retained Removable Dental Prostheses: A Systematic Review and Meta-Analysis.

    Science.gov (United States)

    Lian, Meifei; Zhao, Kai; Feng, Yunzhi; Yao, Qian

    The reliability of combining natural teeth and implants in one removable prosthesis is controversial. This systematic review was conducted to evaluate the prognosis of combined tooth/implant-supported double-crown-retained removable dental prostheses (DCR-RDPs) and to compare them with solely implant-supported prostheses with a minimum observation period of 3 years. Electronic database (PubMed, Embase, Central, and SCI) and manual searches up to August 2016 were conducted to identify human clinical studies on tooth/implant-supported DCR-RDPs. Literature selection and data extraction were accomplished by two independent reviewers. Meta-analyses of survival and complication rates were performed separately for combined tooth/implant-supported and solely implant-supported DCRRDPs. Among the initially identified 366 articles, 17 were included in a quantitative analysis. The estimated overall cumulative survival rate (CSR) for implants in combined tooth/implant-supported DCRRDPs was 98.72% (95% confidence interval [95% CI]: 96.98% to 99.82%), and that for implants in solely implant-supported DCR-RDPs was 98.83% (95% CI: 97.45% to 99.75%). The summary CSR for abutment teeth was 92.96% (95% CI: 85.38% to 98.12%). Double-crown-retained dentures with both abutment types showed high CSRs, most of which were approximately 100%. Regarding prosthetic maintenance treatment, the estimated incidence for patients treated with combined tooth/implant-supported RDPs was 0.164 (95% CI: 0.089 to 0.305) per patient per year (T/P/Y) and that for patients restored with solely implant-supported RDPs was 0.260 (95% CI: 0.149 to 0.454) T/P/Y. Based on four studies with combined tooth/implant-supported DCR-RDPs, no intrusion phenomena were encountered. Subject to the limitations of the present review, combining remaining teeth and implants in DCR-RDPs is a reliable and predictable treatment modality for partially edentulous patients. Comparable high survival rates and minor biologic or

  8. Functionalization of polydimethylsiloxane membranes to be used in the production of voice prostheses

    Directory of Open Access Journals (Sweden)

    Paula Ferreira, Álvaro Carvalho, Tiago Ruivo Correia, Bernardo Paiva Antunes, Ilídio Joaquim Correia and Patrícia Alves

    2013-01-01

    Full Text Available The voice is produced by the vibration of vocal cords which are located in the larynx. Therefore, one of the major consequences for patients subjected to laryngectomy is losing their voice. In these cases, a synthetic one-way valve set (voice prosthesis can be implanted in order to allow restoration of speech. Most voice prostheses are produced with silicone-based materials such as polydimethylsiloxane (PDMS. This material has excellent properties, such as optical transparency, chemical and biological inertness, non-toxicity, permeability to gases and excellent mechanical resistance that are fundamental for its application in the biomedical field. However, PDMS is very hydrophobic and this property causes protein adsorption which is followed by microbial adhesion and biofilm formation. To overcome these problems, surface modification of materials has been proposed in this study. A commercial silicone elastomer, SylgardTM 184 was used to prepare membranes whose surface was modified by grafting 2-hydroxyethylmethacrylate and methacrylic acid by low-pressure plasma treatment. The hydrophilicity, hydrophobic recovery and surface energy of the produced materials were determined. Furthermore, the cytotoxicity and antibacterial activity of the materials were also assessed. The results obtained revealed that the PDMS surface modification performed did not affect the material's biocompatibility, but decreased their hydrophobic character and bacterial adhesion and growth on its surface.

  9. FACTORS RELATED TO ORAL CANDIDIASIS IN ELDERLY USERS AND NON-USERS OF REMOVABLE DENTAL PROSTHESES.

    Science.gov (United States)

    Bianchi, Cyra Maria Pires de Carvalho; Bianchi, Hélcio Aparecido; Tadano, Tomoko; Paula, Claudete Rodrigues de; Hoffmann-Santos, Hugo Dias; Leite, Diniz Pereira; Hahn, Rosane Christine

    2016-01-01

    This study examined the association between oral candidiasis in elderly users and nonusers of prosthesis and its predisposing factors. To this end, we performed a cross-sectional study where saliva samples from 48 patients were collected they used prosthesis and 43 patients (control group) who did not use. Among the 91 patients, Candida spp were isolated in 40 (83.3%) who used prosthesis and in 23 (53.5%) in the control group. A statistically significant association was determined between the two groups, the isolation of yeasts and dental prosthesis (p oral candidiasis (n = 24), 83.3% (n = 20) belonged to the group that wore dentures, while only 16.7% (n = 4) belonged to the control group. Elderly patients with diabetes had 4.4 times higher estimated risk of developing oral candidiasis when compared with individuals without this condition. There was no statistically significant association between being user prostheses and have diabetes with the onset of candidiasis. No statistically significant association was determined between xerostomia, use of prosthesis and oral candidiasis. The use of prosthetics and poor oral hygiene in elderly patients predisposes to the development of oral candidiasis.

  10. Evaluation of non-conformities of hip prostheses made of titanium alloys and stainless steel; Avaliacao de nao conformidades de proteses de quadril fabricadas com ligas de titanio e aco inox

    Energy Technology Data Exchange (ETDEWEB)

    Bezerra, Ewerton de Oliveira Teotonio; Nascimento, Jose Jeferson da Silva; Luna, Carlos Bruno Barreto; Morais, Crislene Rodrigues da Silva; Campos, Karla Valeria Miranda de, E-mail: ewerton.teotonio@hotmail.com, E-mail: brunobarretodemaufcg@hotmail.com [Universidade Federal de Campina Grande (UAEMa/CCT/UFCG), PB (Brazil). Unidade Academinca de Engenharia de Materiais

    2017-01-15

    A large number of metallic alloys has satisfactory behavior when used to manufacture implants for hip prostheses. However, they must be in conformity with standards, to ensure their quality for long periods without losing its functionality. Therefore, this paper aims to study the non-conformities in two hip prostheses, one of titanium and other stainless steel according to standards. The implants studied passed by X-ray diffraction (XRD), X-ray fluorescence, tensile test and optical microscopy (OM). Specimens for the tensile test were made according to ASTM E 8M, as well, MO samples passed by metallographic procedure. The results evidenced that some chemical compositions showed in relation to the standards. The XRD analysis showed peaks of austenite and absence of ferrite for the stainless steel, while the titanium alloy presents an alpha phase (HCP) more significant than the beta phase (BCC). The stainless steel alloys and titanium have yield strength and tensile strength that meet the standards. On the other hand, the elastic modulus of the titanium alloy and stainless steel, comes to be ten times greater than the human bone. Therefore, the high modulus of elasticity of the alloys, favors bone resorption problems. The stainless steel microstructure is typical of an austenitic matrix, while the titanium alloy presents α + β microstructure. (author)

  11. Characterization of interfacial socket pressure in transhumeral prostheses: A case series.

    Directory of Open Access Journals (Sweden)

    Jonathon S Schofield

    Full Text Available One of the most important factors in successful upper limb prostheses is the socket design. Sockets must be individually fabricated to arrive at a geometry that suits the user's morphology and appropriately distributes the pressures associated with prosthetic use across the residual limb. In higher levels of amputation, such as transhumeral, this challenge is amplified as prosthetic weight and the physical demands placed on the residual limb are heightened. Yet, in the upper limb, socket fabrication is largely driven by heuristic practices. An analytical understanding of the interactions between the socket and residual limb is absent in literature. This work describes techniques, adapted from lower limb prosthetic research, to empirically characterize the pressure distribution occurring between the residual limb and well-fit transhumeral prosthetic sockets. A case series analyzing the result of four participants with transhumeral amputation is presented. A Tekscan VersaTek pressure measurement system and FaroArm Edge coordinate measurement machine were employed to capture socket-residual limb interface pressures and geometrically register these values to the anatomy of participants. Participants performed two static poses with their prosthesis under two separate loading conditions. Surface pressure maps were constructed from the data, highlighting pressure distribution patterns, anatomical locations bearing maximum pressure, and the relative pressure magnitudes. Pressure distribution patterns demonstrated unique characteristics across the four participants that could be traced to individual socket design considerations. This work presents a technique that implements commercially available tools to quantitatively characterize upper limb socket-residual limb interactions. This is a fundamental first step toward improved socket designs developed through informed, analytically-based design tools.

  12. Obturator or "lateral" bypass in the management of infected vascular prostheses at the groin

    Directory of Open Access Journals (Sweden)

    Davidović Lazar B.

    2002-01-01

    Full Text Available The infection of the previously implanted vascular graft at the groin, is associated with great mortality and morbidity rate [1]. The authors present a retrospective study in which they analyzed management of infected vascular prostheses at the groin, using obturator bypass in 26 cases, and "lateral" bypass in 15 cases. The indications for obturator bypass reconstructions included: 20 infections of aorto-femoral grafts, two infected pse udoaneurysms in the groin after RTA of the superficial femoral artery, and 4 infections of iliac-femoral grafts. The indications for lateral bypass reconstructions were: infections after aorto-femoral reconstructions - 8 cases; infection after femora-popliteal reconstructions - 4 cases; infection after iliac-femoral reconstruction - 2 patients, and one infected pseudoaneurysm in the groin after RTA of the superficial femoral artery. In 3 subjects obturator bypass was performed using extraperitoneal approach while in other 23 patients transperitoneal approach was done by donor's artery. The obturator bypass was performed using a PTFE graft in 3 cases and Dacron graft in 23. The donor's artery used for obturator bypass was a noninfected proximal part of aortofemoral graft in 20 cases, and iliac artery in 6 patients. The superfical femoral artery was recipient artery for obturator bypass in 3 cases, deep femoral artery in one case, and above the knee popliteal artery in 22 cases (Figure 1. In two patients transperitoenal approach to donors artery for "lateral" bypass has been used, and in 13 cases extraperitoneal. The proximal noninfected part of aorto femoral graft was used as a donor's artery for lateral bypass in 8 patients, while common iliac artery in 7 subjects. In 5 cases recon structions were performed using PTFE grafts, in 3 using autologous saphenous vein grafts, and in 7 using Dacron grafts. The recipient artery for "lateral" bypass was deep femoral in 8 cases, superficial femoral in three patients and

  13. Individual Leg and Joint Work during Sloped Walking for People with a Transtibial Amputation Using Passive and Powered Prostheses

    Directory of Open Access Journals (Sweden)

    Jana R. Jeffers

    2017-12-01

    Full Text Available People with a transtibial amputation using passive-elastic prostheses exhibit reduced prosthetic ankle power and push-off work compared to non-amputees and compensate by increasing their affected leg (AL hip joint work and unaffected leg (UL ankle, knee, and hip joint and leg work during level-ground walking. Use of a powered ankle–foot prosthesis normalizes step-to-step transition work during level-ground walking over a range of speeds for people with a transtibial amputation, but the effects on joint work during level-ground, uphill, and downhill walking have not been assessed. We investigated how use of passive-elastic and powered ankle–foot prostheses affect leg joint biomechanics during level-ground and sloped walking. 10 people with a unilateral transtibial amputation walked at 1.25 m/s on a dual-belt force-measuring treadmill at 0°, ±3°, ±6°, and ±9° using their own passive-elastic and a powered prosthesis (BiOM T2, BionX Medical Technologies, Inc., Bedford, MA, USA while we measured kinematic and kinetic data. We calculated AL and UL prosthetic, ankle, knee, hip, and individual leg positive, negative, and net work. Use of a powered compared to passive-elastic ankle–foot prosthesis resulted in greater AL prosthetic and individual leg net work on uphill and downhill slopes. Over a stride, AL prosthetic positive work was 23–30% greater (p < 0.05 during walking on uphill slopes of +6°, and +9°, prosthetic net work was up to 10 times greater (more positive (p ≤ 0.005 on all uphill and downhill slopes and individual leg net work was 146 and 82% more positive (p < 0.05 at uphill slopes of +6° and +9°, respectively, with use of the powered compared to passive-elastic prosthesis. Greater prosthetic positive and net work through use of a powered ankle–foot prosthesis during uphill and downhill walking improves mechanical work symmetry between the legs, which could decrease metabolic cost and improve functional

  14. Radiological follow-up of uncemented knee prostheses. Preliminary study. Seguimiento radiologico de protesis de rodilla no cementadas. Estudio preliminar

    Energy Technology Data Exchange (ETDEWEB)

    Martin Hervas, C.; Gomez Barrena, E.; Marquez Moreno, I.; Calle Yuste, F.; Ordoez Parra, J.M.

    1993-10-01

    The preliminary results of a prospective study of 40 uncemented total knee prostheses (TKP) are presented following a radiological protocol with fluoroscopic control and follow-up of over 2 years. The prosthesis-bone interface and the components alignment were assessed. Several radiological signs were studied to assess this interface with respect to the fixing of the component, but they showed little clinical correlation. Statistical significance (p<0.05, chisquare) was found only in the observation of sclerosis in areas of support for the tibital tray as a reaction of the bone. This radiological follow-up is of interest to determine the evolution of the interface and position of the implant to prevent complications (especially loosening) in patients, particularly those under 60 years old, who represent the group that can most benefit from prosthetic systems with uncemented anchorage because of their life expectation and level of activity. Author

  15. Cardiac arrest due to left circumflex coronary artery embolism as a complication of subtherapeutic oral anticoagulation in a patient with mitral and aortic mechanical valve prostheses.

    Science.gov (United States)

    Protasiewicz, Marcin; Rojek, Aleksandra; Gajek, Jacek; Mysiak, Andrzej

    2013-01-01

    We report a case of a 65-year-old female patient after replacement of aortic and mitral valve with mechanical prostheses and implantation of a pacemaker hospitalized in our clinic due to acute coronary syndrome complicated with cardiac arrest due to ventricular fibrillation. The electrocardiogram performed on admission showed signs of myocardial infarction with concomitant ventricular pacing. After successful resuscitation the coronary angiography was performed, which showed occlusion of the left circumflex artery (LCx) by thrombus. On the basis of intravascular ultrasound imaging the presence of vulnerable plaque, parietal thrombus and dissection of LCx were excluded. It suggested that occlusion of the LCx resulted from its embolism by left-sided heart thrombus due to subtherapeutic oral anticoagulation. In this case suboptimal anticoagulation was partially iatrogenic. Two weeks before the patient had been given vitamin K intravenously due to indeterminable international normalized ratio (INR) level, which caused transient resistance to oral anticoagulants. This case report illustrates tragic difficulties in the treatment with vitamin K antagonists, which concern as many as 2/3 of anticoagulated patients. These troubles contributed to the search for new, more efficient and safer anticoagulants. There are two classes of new oral anticoagulant drugs, which do not require monitoring of coagulation: direct thrombin inhibitors (e.g. dabigatran) and factor Xa inhibitors (e.g. rivaroxaban). In spite of their proven efficacy in the prevention of ischaemic stroke related to atrial fibrillation and prevention or treatment of deep vein thrombosis and pulmonary embolism, the use of new oral anticoagulants for the treatment of patients with mechanical valve prostheses needs further research.

  16. Marginal Vertical Discrepancies of Monolithic and Veneered Zirconia and Metal-Ceramic Three-Unit Posterior Fixed Dental Prostheses.

    Science.gov (United States)

    Lopez-Suarez, Carlos; Gonzalo, Esther; Pelaez, Jesus; Serrano, Benjamin; Suarez, Maria J

    2016-01-01

    The aim of this study was to investigate and compare the marginal fit of posterior fixed dental prostheses (FDPs) made of monolithic and veneered computer-aided design/computer-assisted manufacture (CAD/CAM) zirconia ceramic with metal-ceramic posterior FDPs. Thirty standardized steel dies were prepared to receive posterior three-unit FDPs. Specimens were randomly divided into three groups (n = 10): (1) metal-ceramic (control group), (2) veneered zirconia, and (3) monolithic zirconia. All FDPs were cemented using a glass-ionomer cement. The specimens were subjected to thermal cycling (5°C to 55°C). A scanning electron microscope (SEM) with a magnification of ×500 was used for measurements. The data were statistically analyzed using one-way analysis of variance and paired t test. Both zirconia groups showed similar vertical marginal discrepancies, and no significant differences (P = .661) in marginal adaptation were observed among the groups. No differences were observed in either group in marginal discrepancies between surfaces or abutments. Monolithic zirconia posterior FDPs exhibit similar vertical marginal discrepancies to veneered zirconia posterior FDPs. No influence of localization measurements was observed.

  17. Ankle mechanics during sidestep cutting implicates need for 2-degrees of freedom powered ankle-foot prostheses.

    Science.gov (United States)

    Ficanha, Evandro M; Rastgaar, Mohammad; Kaufman, Kenton R

    2015-01-01

    The ankle joint of currently available powered prostheses is capable of controlling one degree of freedom (DOF), focusing on improved mobility in the sagittal plane. To increase agility, the requirements of turning in prosthesis design need to be considered. Ankle kinematics and kinetics were studied during sidestep cutting and straight walking. There were no significant differences between the ankle sagittal plane mechanics when comparing sidestep cutting and straight walking; however, significant differences were observed in ankle frontal plane mechanics. During straight walking, the inversion-eversion (IE) angles were smaller than with sidestep cutting. The ankle that initiated the sidestep cutting showed progressively increasing inversion from 2 to 13 degrees while the following contralateral step showed progressively decreasing inversion from 8 to -4 degrees during normal walking speed. The changes in IE kinematics were the most significant during sidestep cutting compared with straight walking. The IE moments of the step that initiated the sidestep cutting were always in eversion, acting as a braking moment opposing the inverting motion. This suggests that an ankle-foot prosthesis with active DOFs in the sagittal and frontal planes will increase the agility of gait for patients with limb loss.

  18. Clinical Fit of Partial Removable Dental Prostheses Based on Alginate or Polyvinyl Siloxane Impressions.

    Science.gov (United States)

    Fokkinga, Wietske A; Witter, Dick J; Bronkhorst, Ewald M; Creugers, Nico H

    The aim of this study was to analyze the clinical fit of metal-frame partial removable dental prostheses (PRDPs) based on custom trays used with alginate or polyvinyl siloxane impression material. Fifth-year students of the Nijmegen Dental School made 25 correct impressions for 23 PRDPs for 21 patients using alginate, and 31 correct impressions for 30 PRDPs for 28 patients using polyvinyl siloxane. Clinical fit of the framework as a whole and of each retainer separately were evaluated by calibrated supervisors during framework try-in before (first evaluation) and after (second evaluation) possible adjustments (score 0 = poor fit, up to score 3 = good fit). Framework fit and fit of the denture base were evaluated at delivery (third evaluation). Finally, postinsertion sessions were evaluated and total number of sessions needed, sore spots, adjustments to the denture base, and reported food-impaction were recorded. No significant differences in clinical fit (of the framework as a whole, for the retainers, or for the denture base) were found between the groups in the three evaluation sessions. Differences were not found for postinsertion sessions with one exception: in the alginate group, four subjects reported food impaction, versus none in the polyvinyl siloxane group. Clinical fit of metal-frame PRDPs based on impressions with custom trays combined with alginate or polyvinyl siloxane was similar.

  19. Enhancing the soft tissue seal around intraosseous transcutaneous amputation prostheses using silanized fibronectin titanium alloy

    Energy Technology Data Exchange (ETDEWEB)

    Chimutengwende-Gordon, M; Pendegrass, C; Blunn, G, E-mail: mukai.cg@mac.com [Centre for Biomedical Engineering, Institute of Orthopaedics and Musculoskeletal Science, University College London, Brockley Hill, Stanmore, HA7 4LP (United Kingdom)

    2011-04-15

    The success of intraosseous transcutaneous amputation prostheses (ITAP) relies on achieving a tight seal between the soft tissues and the implant in order to avoid infection. Fibronectin (Fn) may be silanized onto titanium alloy (Ti-6Al-4V) in order to promote soft-tissue attachment. The silanization process includes passivation with sulphuric acid, which alters surface characteristics. This study aimed to improve in vitro fibroblast adhesion to silanized fibronectin (SiFn) titanium alloy by omitting the passivation stage. Additionally, the study assessed the effects of SiFn on in vivo dermal attachment, comparing the results with adsorbed Fn, hydroxyapatite (HA), Fn adsorbed onto HA (HAFn) and uncoated controls. Surface topography was assessed using scanning electron microscopy, profilometry and contact angle measurement. Anti-vinculin antibodies were used to immunolocalize fibroblast adhesion sites. A histological assessment of soft-tissue attachment and cell alignment relative to implants in an in vivo ovine model was performed. Passivation resulted in rougher, more hydrophobic, microcracked surfaces and was associated with poorer fibroblast adhesion than unpassivated controls. SiFn and HAFn surfaces resulted in more favourable cell alignment in vivo, implying that dermal attachment was enhanced. These results suggest that SiFn and HAFn surfaces could be useful in optimizing the soft tissue seal around ITAP.

  20. A systematic review of the clinical performance of tooth-retained and implant-retained double crown prostheses with a follow-up of ≥ 3 years.

    Science.gov (United States)

    Verma, Rohini; Joda, Tim; Brägger, Urs; Wittneben, Julia-Gabriela

    2013-01-01

    The objective of this review was to systematically screen the literature for data related to the survival and complication rates observed with dental or implant double crown abutments and removable prostheses under functional loading for at least 3 years. A systematic review of the dental literature from January 1966 to December 2009 was performed in electronic databases (PubMed and Embase) as well as by an extensive hand search to investigate the clinical outcomes of double crown reconstructions. From the total of 2412 titles retrieved from the search, 65 were selected for full-text review. Subsequently, 17 papers were included for data extraction. An estimation of the cumulative survival and complication rates was not feasible due to the lack of detailed information. Tooth survival rates for telescopic abutment teeth ranged from 82.5% to 96.5% after an observation period of 3.4 to 6 years, and for tooth-supported double crown retained dentures from 66.7% to 98.6% after an observation period of 6 to 10 years. The survival rates of implants were between 97.9% and 100% and for telescopic-retained removable dental prostheses with two mandibular implants, 100% after 3.0 and 10.4 years. The major biological complications affecting the tooth abutments were gingival inflammation, periodontal disease, and caries. The most frequent technical complications were loss of cementation and loss of facings. The main findings of this review are: (I) double crown tooth abutments and dentures demonstrated a wide range of survival rates. (II) Implant-supported mandibular overdentures demonstrated a favorable long-term prognosis. (III) A greater need for prosthetic maintenance is required for both tooth-supported and implant-supported reconstructions. (IV) Future areas of research would involve designing appropriate longitudinal studies for comparisons of survival and complication rates of different reconstruction designs. © 2012 by the American College of Prosthodontists.

  1. A comparison of the marginal vertical discrepancies of zirconium and metal ceramic posterior fixed dental prostheses before and after cementation.

    Science.gov (United States)

    Gonzalo, Esther; Suárez, Maria J; Serrano, Benjamin; Lozano, Jose F L

    2009-12-01

    Marginal discrepancies of zirconia posterior fixed dental prostheses (FDPs) fabricated using various systems have been assessed to determine the quality of the restorations and facilitate clinical use; however, studies are limited and results are ambiguous because of the sample sizes and measurement methods. The purpose of this in vitro study was to compare changes in marginal fit of posterior fixed dental prostheses of 3 zirconia systems manufactured using CAD/CAM technology and metal ceramic posterior fixed dental protheses fabricated with the conventional lost-wax technique, before and after cementation. Forty standardized master steel dies with 2 abutments simulating first mandibular premolars were fabricated to receive a posterior 3-unit FDP (from first molar to first premolar) and divided into 4 groups (n=10): Lava All-Ceramic System, Procera Bridge Zirconia, VITA In-Ceram 2000 YZ, and metal ceramic (control group). All FDPs were prepared for an internal space of 50 microm. The external marginal gap of the restorations was investigated by measuring 30 points in the middle of the buccal and lingual surfaces; therefore, 60 measurements per abutment were recorded. Measurements were made with an image analysis program on the master steel model before and after conventional cementation with a glass ionomer agent (Ketac Cem Easymix). The data obtained were statistically analyzed using 1-way ANOVA, Duncan's multiple range post hoc test, and Student's paired t test (alpha=.05). No significant differences in the vertical marginal fit before and after cementation were recorded for the analyzed groups. The marginal discrepancy of Procera abutments before and after cementation (9 +/-10 microm and 12 +/-9 microm, respectively) was less than that of the other groups. Significant differences (P=.001) were observed in marginal adaptation between Procera Bridge Zirconia and the other groups. The results of this study showed that cementation did not cause a significant

  2. MR imaging with metal artifact-reducing sequences and gadolinium contrast agent in a case-control study of periprosthetic abnormalities in patients with metal-on-metal hip prostheses

    Energy Technology Data Exchange (ETDEWEB)

    Mueller, Gunilla M.; Mueller, Markus F.; Ekberg, Olle [Lund University, Skaane University Hospital, Department of Radiology, Malmoe (Sweden); Maansson, Sven [Lund University, Skaane University Hospital, Department of Medical Radiation Physics, Malmoe (Sweden); Schewelov, Thord von [Lund University, Skaane University Hospital, Department of Orthopedic Surgery, Malmoe (Sweden); Nittka, Mathias [Siemens AG, Healthcare Sector, Erlangen (Germany); Lundin, Bjoern [Lund University, Skaane University Hospital, Department of Radiology, Lund (Sweden)

    2014-08-15

    To apply and compare magnetic resonance imaging (MRI) metal artifact reducing sequences (MARS) including subtraction imaging after contrast application in patients with metal-on-metal (MoM) hip prostheses, investigate the prevalence and characteristics of periprosthetic abnormalities, as well as their relation with pain and risk factors. Fifty-two MoM prostheses (35 cases with pain and or risk factors, and 17 controls) in 47 patients were examined in a 1.5-T MR scanner using MARS: turbo spin echo (TSE) with high readout bandwidth with and without view angle tilting (VAT), TSE with VAT and slice encoding for metal artifact correction (SEMAC), short tau inversion recovery (STIR) with matched RF pulses, and post-contrast imaging. The relations of MRI findings to pain and risk factors were analyzed and in five revised hips findings from operation, histology, and MRI were compared. TSE VAT detected the highest number of osteolyses. Soft tissue mass, effusion, and capsular thickening were common, whereas osteolysis in acetabulum and femur were less frequent. Contrast enhancement occurred in bone, synovia, joint capsule, and the periphery of soft tissue mass. There was no significant relation between MRI findings and pain or risk factors. MARS and gadolinium subtraction imaging are useful for evaluation of complications to MoM prosthesis. TSE VAT had the highest sensitivity for osteolysis. Contrast enhancement might indicate activation of aseptic lymphocyte-dominated vasculitis-associated lesion (ALVAL). Pain, small head, or steep prosthesis inclination angle are not useful predictors of periprosthetic abnormalities, and wide indications for MR follow-up are warranted. (orig.)

  3. A prospective 5-year study of fixed partial prostheses supported by implants with machined and TiO2-blasted surface

    DEFF Research Database (Denmark)

    Gotfredsen, K; Karlsson, U

    2001-01-01

    PURPOSE: The aim of the present study was to evaluate whether there was a difference between machined and TiO(2)-blasted implants regarding survival rate and marginal bone loss during a 5-year observation period. MATERIALS AND METHODS: A total of 133 implants (Astra Tech Dental Implants; Astra Tech...... AB, Mölndal, Sweden) were placed in 50 patients at 6 centers in 4 Scandinavian countries. Forty-eight implants were installed in the maxilla and 85 implants in the mandible. A randomization and a stratification were done, so that each fixed partial prosthesis was supported by at least 1 machined...... and 1 TiO(2)-blasted implant. The implant-supported fixed partial prostheses (ISFPP) were fabricated within 2 months after postoperative healing. A total of 52 ISFPP (17 maxillary, 35 mandibular) were inserted. The patients were clinically examined once a year for 5 years. At the annual follow...

  4. Four-unit fixed dental prostheses replacing the maxillary incisors supported by two narrow-diameter implants - a five-year case series.

    Science.gov (United States)

    Moráguez, Osvaldo; Vailati, Francesca; Grütter, Linda; Sailer, Irena; Belser, Urs C

    2017-07-01

    (1) To determine the survival rate of 10 four-unit fixed dental prostheses (FDPs) replacing the four maxillary incisors, supported by 20 narrow-diameter implants (NDIs), (2) to assess the incidence of mechanical and biological complications, and (3) to evaluate bone level changes longitudinally after final FDP insertion. Ten patients (six women, four men), mean age 49.4 ± 12.6 years, were treated with a four-unit anterior maxillary FDP (six screw-retained; four cemented). Biological parameters, eventual technical complications, radiographic measurements, and study casts were assessed at 1 (baseline), 3, and 5 years after implant placement. A multilevel logistic regression test was performed on clinical parameters and bone level changes (significance level P four-unit FDP to replace the four missing maxillary incisors may be considered a predictable treatment modality. © 2016 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  5. Optimization of metal artefact reduction (MAR) sequences for MRI of total hip prostheses

    Energy Technology Data Exchange (ETDEWEB)

    Toms, A.P., E-mail: andoni.toms@nnuh.nhs.u [Department of Radiology, Norfolk and Norwich University Hospital Trust, Norwich, Norfolk NR4 7UY (United Kingdom); Smith-Bateman, C.; Malcolm, P.N.; Cahir, J. [Department of Radiology, Norfolk and Norwich University Hospital Trust, Norwich, Norfolk NR4 7UY (United Kingdom); Graves, M. [University Department of Radiology, Addenbrooke' s Hospital, Cambridge (United Kingdom)

    2010-06-15

    Aim: To describe the relative contribution of matrix size and bandwidth to artefact reduction in order to define optimal sequence parameters for metal artefact reduction (MAR) sequences for MRI of total hip prostheses. Methods and materials: A phantom was created using a Charnley total hip replacement. Mid-coronal T1-weighted (echo time 12 ms, repetition time 400 ms) images through the prosthesis were acquired with increasing bandwidths (150, 300, 454, 592, and 781 Hz/pixel) and increasing matrixes of 128, 256, 384, 512, 640, and 768 pixels square. Signal loss from the prosthesis and susceptibility artefact was segmented using an automated tool. Results: Over 90% of the achievable reduction in artefacts was obtained with matrixes of 256 x 256 or greater and a receiver bandwidth of approximately 400 Hz/pixel or greater. Thereafter increasing the receiver bandwidth or matrix had little impact on reducing susceptibility artefacts. Increasing the bandwidth produced a relative fall in the signal-to-noise ratio (SNR) of between 49 and 56% for a given matrix, but, in practice, the image quality was still satisfactory even with the highest bandwidth and largest matrix sizes. The acquisition time increased linearly with increasing matrix parameters. Conclusion: Over 90% of the achievable metal artefact reduction can be realized with mid-range matrices and receiver bandwidths on a clinical 1.5 T system. The loss of SNR from increasing receiver bandwidth, is preferable to long acquisition times, and therefore, should be the main tool for reducing metal artefact.

  6. Feature extraction using extrema sampling of discrete derivatives for spike sorting in implantable upper-limb neural prostheses.

    Science.gov (United States)

    Zamani, Majid; Demosthenous, Andreas

    2014-07-01

    Next generation neural interfaces for upper-limb (and other) prostheses aim to develop implantable interfaces for one or more nerves, each interface having many neural signal channels that work reliably in the stump without harming the nerves. To achieve real-time multi-channel processing it is important to integrate spike sorting on-chip to overcome limitations in transmission bandwidth. This requires computationally efficient algorithms for feature extraction and clustering suitable for low-power hardware implementation. This paper describes a new feature extraction method for real-time spike sorting based on extrema analysis (namely positive peaks and negative peaks) of spike shapes and their discrete derivatives at different frequency bands. Employing simulation across different datasets, the accuracy and computational complexity of the proposed method are assessed and compared with other methods. The average classification accuracy of the proposed method in conjunction with online sorting (O-Sort) is 91.6%, outperforming all the other methods tested with the O-Sort clustering algorithm. The proposed method offers a better tradeoff between classification error and computational complexity, making it a particularly strong choice for on-chip spike sorting.

  7. Thermal time constant: optimising the skin temperature predictive modelling in lower limb prostheses using Gaussian processes.

    Science.gov (United States)

    Mathur, Neha; Glesk, Ivan; Buis, Arjan

    2016-06-01

    Elevated skin temperature at the body/device interface of lower-limb prostheses is one of the major factors that affect tissue health. The heat dissipation in prosthetic sockets is greatly influenced by the thermal conductive properties of the hard socket and liner material employed. However, monitoring of the interface temperature at skin level in lower-limb prosthesis is notoriously complicated. This is due to the flexible nature of the interface liners used which requires consistent positioning of sensors during donning and doffing. Predicting the residual limb temperature by monitoring the temperature between socket and liner rather than skin and liner could be an important step in alleviating complaints on increased temperature and perspiration in prosthetic sockets. To predict the residual limb temperature, a machine learning algorithm - Gaussian processes is employed, which utilizes the thermal time constant values of commonly used socket and liner materials. This Letter highlights the relevance of thermal time constant of prosthetic materials in Gaussian processes technique which would be useful in addressing the challenge of non-invasively monitoring the residual limb skin temperature. With the introduction of thermal time constant, the model can be optimised and generalised for a given prosthetic setup, thereby making the predictions more reliable.

  8. Marginal and internal fit of cobalt-chromium fixed dental prostheses generated from digital and conventional impressions.

    Science.gov (United States)

    Svanborg, Per; Skjerven, Henrik; Carlsson, Pablo; Eliasson, Alf; Karlsson, Stig; Ortorp, Anders

    2014-01-01

    Objectives. Digital impressions are increasingly used and have the potential to avoid the problem of inaccurate impressions. Only a few studies to verify the accuracy of digital impressions have been performed. The purpose of this study was to compare the marginal and internal fit of 3-unit tooth supported fixed dental prostheses (FDPs) fabricated from digital and conventional impressions. Methods. Ten FDPs were produced from digital impressions using the iTero system and 10 FDPs were produced using vinyl polysiloxane (VPS) impression material. A triple-scan protocol and CAD software were used for measuring and calculating discrepancies of the FDPs at 3 standard areas: mean internal discrepancy, absolute marginal gap, and cervical area discrepancy. The Mann-Whitney U test was used for analyzing the results. Results. For conventional and digital impressions, respectively, FDPs had an absolute marginal gap of 147  μ m and 142  μ m, cervical area discrepancy of 69  μ m and 44  μ m, and mean internal discrepancy of 117  μ m and 93  μ m. The differences were statistically significant in the cervical and internal areas (P digital impression technique is more exact and can generate 3-unit FDPs with a significantly closer fit compared to the VPS technique.

  9. Waterjet cutting of periprosthetic interface tissue in loosened hip prostheses: an in vitro feasibility study.

    Science.gov (United States)

    Kraaij, Gert; Tuijthof, Gabrielle J M; Dankelman, Jenny; Nelissen, Rob G H H; Valstar, Edward R

    2015-02-01

    Waterjet cutting technology is considered a promising technology to be used for minimally invasive removal of interface tissue surrounding aseptically loose hip prostheses. The goal of this study was to investigate the feasibility of waterjet cutting of interface tissue membrane. Waterjets with 0.2 mm and 0.6 mm diameter, a stand-off distance of 5 mm, and a traverse speed of 0.5 mm/s were used to cut interface tissue samples in half. The water flow through the nozzle was controlled by means of a valve. By changing the flow, the resulting waterjet pressure was regulated. Tissue sample thickness and the required waterjet pressures were measured. Mean thickness of the samples tested within the 0.2 mm nozzle group was 2.3 mm (SD 0.7 mm) and within the 0.6 mm nozzle group 2.6 mm (SD 0.9 mm). The required waterjet pressure to cut samples was between 10 and 12 MPa for the 0.2 mm nozzle and between 5 and 10 MPa for the 0.6 mm nozzle. Cutting bone or bone cement requires about 3 times higher waterjet pressure (30-50 MPa, depending on used nozzle diameter) and therefore we consider waterjet cutting as a safe technique to be used for minimally invasive interface tissue removal. Copyright © 2015 IPEM. Published by Elsevier Ltd. All rights reserved.

  10. Maxillary and mandibular immediately loaded implant-supported interim complete fixed dental prostheses on immediately placed dental implants with a digital approach: A clinical report.

    Science.gov (United States)

    Lewis, Ryan C; Harris, Bryan T; Sarno, Robert; Morton, Dean; Llop, Daniel R; Lin, Wei-Shao

    2015-09-01

    This clinical report describes the treatment of maxillary and mandibular immediate implant placement and immediately loaded implant-supported interim complete fixed dental prostheses with a contemporary digital approach. The virtual diagnostic tooth arrangement eliminated the need for a customized radiographic template, and the diagnostic data collection required for computer-guided surgery (digital diagnostic impressions, digital photographs, and a cone beam-computed tomography [CBCT] scan) was completed in a single visit with improved workflow efficiency. Computer-aided design and computer-aided manufacturing (CAD/CAM)-fabricated surgical templates and interim prosthesis templates were made in a dental laboratory to facilitate computer-guided surgery and the immediate loading process. Copyright © 2015 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.

  11. [Technical complications rates and plaque control of fixed dental prostheses in patients treated for periodontal disease].

    Science.gov (United States)

    Xie, Yesi; Meng, Huanxin; Han, Jie; Pan, Shaoxia; Zhang, Li; Shi, Dong

    2016-02-01

    To compare the incidence of technical complications of implant-supported fixed dental prostheses in Chinese patients with a history of moderate or severe periodontitis and periodontally healthy patients(PHP) and analyze the effects of interproximal papillae patterns on food impaction and efficacy of plaque control. A total of 103 partially edentulous patients treated with implant-supported fixed dental prostheses between December 2009 and December 2012 for a minimum 1-year follow-up period were recruited from Department of Periodontology, Peking University, School and Hospital of Stomatology. Based on the initial periodontal examination, the participants were divided into three groups: 30 PHP, 36 moderate periodontally compromised patients(mPCP) and 37 severe periodontally compromised patients(sPCP). Implant survival/loss, technical complications, plaque index, papilla index, food impaction and degree of proximal contact tightness of each patient were assessed around the implants at follow-up. According to the implant papilla index, the implants were divided into two groups: the "filling" group with the mesial and distal aspects with papilla index=3 and the "no filling" group with at least one aspect with papilla indextechnical complications were analyzed. Comparisons of the incidence of technical complications were performed between the patients with different periodontal conditions with chi-square or Fisher's exact test. The influences of the interproximal papillae loss on food impaction and efficacy of plaque control were estimated with chi-square and Mann-Whitney U tests. The total implant survival rate was 100%(162/162) for all three groups. Technical complications were as following: veneer fractures(1.9%, 3/162), abutment screw loosening(1.9%, 3/162), prosthetic screw loosening(3.1%, 5/162) and decementation(3.1%, 5/162) in all subjects. No implant/screw fracture was noted. The incidence of technical complications in sPCP, mPCP and PHP did not yield

  12. The role of welding techniques in the biomechanical behavior of implant-supported prostheses.

    Science.gov (United States)

    Rodrigues, Sabrina Alessandra; Presotto, Anna Gabriella Camacho; Barão, Valentim Adelino Ricardo; Consani, Rafael Leonardo Xediek; Nóbilo, Mauro Antônio Arruda; Mesquita, Marcelo Ferraz

    2017-09-01

    This in vitro study investigated the role of welding techniques of implant-supported prostheses in the 2D and 3D marginal misfits of prosthetic frameworks, strain induced on the mini abutment, and detorque of prosthetic screws. The correlations between the analyzed variables were also investigated. Frameworks were cast in commercially pure titanium (cp-Ti). A marginal misfit of 200μm was simulated in the working models (control group) (n=20). The 2D marginal misfit was analyzed according to the single-screw test protocol using a precision optical microscope. The 3D marginal misfit was performed by X-ray microtomography. Strain gauge analysis was performed to investigate the strain induced on the mini abutment. A digital torque meter was used for analysis of the detorque and the mean value was calculated for each framework. Afterwards, the frameworks were divided into two experimental groups (n=10): Laser (L) and TIG (T). The welding techniques were performed according to the following parameters: L (390V/9ms); T (36A/60ms). The L and T groups were reevaluated according to the marginal misfit, strain, and detorque. The results were submitted to one-way ANOVA followed by Tukey's HSD test and Person correlation analysis (α=0.05). Welding techniques statistically reduced the 2D and 3D marginal misfits of prosthetic frameworks (p0.05). Positive correlations were observed between 2D and 3D marginal misfit reading methods (r=0.943, pwelding techniques improved the biomechanical behavior of the implant-supported system. TIG can be an acceptable and affordable technique to reduce the misfit of 3-unit Ti frameworks. Copyright © 2017 Elsevier B.V. All rights reserved.

  13. Designing and assessing fixed dental prostheses 2 multimedia-based education in dentistry students.

    Science.gov (United States)

    Jahandideh, Yousef; Roohi Balasi, Leila; Vadiati Saberi, Bardia; Dadgaran, Ideh

    2016-01-01

    Background: Above all methods effective learning results from decent training, acquired in the proper environment and encouraging creative methods. Computer-assisted training by educational software is considered a fundamental measure to improve medical and dentistry education systems. This study aims to design and assess fixed dental prostheses via 2 multimedia instructional contents at the Guilan dentistry school. Methods: This is a descriptive and cross-sectional study. First off, the instructional content was analyzed. The software used to produce multimedia was the iSpring suite Ver.7.0. After designing the instructional multimedia, this software was loaded by LMS. Sixty-nine dentistry students in the 5th semester at Guilan Dentistry School were selected via convenience sampling. At the end of the course, a structured questionnaire containing 26 items were handed to the students to evaluate the instructional multimedia quality. Results: Mean ±SD age was 24.68±3.24 years, 43 were women (62.4%) and 26 were men (37.6%) -the majority of 76.8% used the internet at home. A portion of 33.3% were inclined to use multimedia and the internet with in-person training. About 60% declared that multimedia quality as being good. Conclusion: the instructional multimedia designs which are compatible with lesson objectives and audiovisual facilities can have a great effect on the student's satisfaction. Preparing instructional multimedia makes the instructional content easily accessible for students to be able to review it several times at the proper opportunity and if presented through LMS they would be able to study the lesson subject wherever and whenever accessing the internet.

  14. Radiographic evaluation of bone adaptation adjacent to percutaneous osseointegrated prostheses in a sheep model.

    Science.gov (United States)

    Jeyapalina, Sujee; Beck, James Peter; Bachus, Kent N; Chalayon, Ornusa; Bloebaum, Roy D

    2014-10-01

    Percutaneous osseointegrated prostheses (POPs) are being investigated as an alternative to conventional socket suspension and require a radiographic followup in translational studies to confirm that design objectives are being met. In this 12-month animal study, we determined (1) radiographic signs of osseointegration and (2) radiographic signs of periprosthetic bone hypertrophy and resorption (adaptation) and (3) confirmed them with the histologic evidence of host bone osseointegration and adaptation around a novel, distally porous-coated titanium POP with a collar. A POP device was designed to fit the right metacarpal bone of sheep. Amputation and implantation surgeries (n = 14) were performed, and plane-film radiographs were collected quarterly for 12 months. Radiographs were assessed for osseointegration (fixation) and bone adaptation (resorption and hypertrophy). The cortical wall and medullary canal widths were used to compute the cortical index and expressed as a percentage. Based on the cortical index changes and histologic evaluations, bone adaptation was quantified. Radiographic data showed signs of osseointegration including those with incomplete seating against the collar attachment. Cortical index data indicated distal cortical wall thinning if the collar was not seated distally. When implants were bound proximally, bone resorbed distally and the diaphyseal cortex hypertrophied. Histopathologic evidence and cortical index measurements confirmed the radiographic indications of adaptation and osseointegration. Distal bone loading, through collar attachment and porous coating, limited the distal bone resorption. Serial radiographic studies, in either animal models or preclinical trials for new POP devices, will help to determine which designs are likely to be safe over time and avoid implant failures.

  15. Estimation of distal arm joint angles from EMG and shoulder orientation for transhumeral prostheses.

    Science.gov (United States)

    Akhtar, Aadeel; Aghasadeghi, Navid; Hargrove, Levi; Bretl, Timothy

    2017-08-01

    In this paper, we quantify the extent to which shoulder orientation, upper-arm electromyography (EMG), and forearm EMG are predictors of distal arm joint angles during reaching in eight subjects without disability as well as three subjects with a unilateral transhumeral amputation and targeted reinnervation. Prior studies have shown that shoulder orientation and upper-arm EMG, taken separately, are predictors of both elbow flexion/extension and forearm pronation/supination. We show that, for eight subjects without disability, shoulder orientation and upper-arm EMG together are a significantly better predictor of both elbow flexion/extension during unilateral (R 2 =0.72) and mirrored bilateral (R 2 =0.72) reaches and of forearm pronation/supination during unilateral (R 2 =0.77) and mirrored bilateral (R 2 =0.70) reaches. We also show that adding forearm EMG further improves the prediction of forearm pronation/supination during unilateral (R 2 =0.82) and mirrored bilateral (R 2 =0.75) reaches. In principle, these results provide the basis for choosing inputs for control of transhumeral prostheses, both by subjects with targeted motor reinnervation (when forearm EMG is available) and by subjects without target motor reinnervation (when forearm EMG is not available). In particular, we confirm that shoulder orientation and upper-arm EMG together best predict elbow flexion/extension (R 2 =0.72) for three subjects with unilateral transhumeral amputations and targeted motor reinnervation. However, shoulder orientation alone best predicts forearm pronation/supination (R 2 =0.88) for these subjects, a contradictory result that merits further study. Copyright © 2017 Elsevier Ltd. All rights reserved.

  16. A review of clinical and technical considerations for fixed and removable implant prostheses in the edentulous mandible.

    Science.gov (United States)

    Zitzmann, Nicola Ursula; Marinello, Carlo Paolo

    2002-01-01

    The aim of the present article is to review some of the technical treatment options for implant prostheses restoring the edentulous mandible, mainly based on the Brånemark system. Clinical and technical aspects are discussed for the three established concepts: (1) implant-supported fixed prosthesis, (2) removable implant-supported overdenture, and (3) combined implant-retained and soft tissue-supported overdenture prosthesis. The framework of an implant-supported fixed screw-retained prosthesis can be processed in gold, Co-Cr alloy, or titanium with casting, laser-welding, or milling techniques. To improve the stability and retention of a conventional complete denture, one to four implants are indicated, and unsplinted (single attachments) or splinted designs (bar systems) can be applied. The design of the overdenture prosthesis must be carefully planned according to the requirements to ensure adequate stability and optimal form, contour, and esthetics, and the patient's best comfort. A large variety of different treatment modalities exist for both the fixed and removable mandibular implant prosthesis. Clinical and technical aspects should be considered at the beginning of the treatment to: (1) select the optimal implant position, (2) establish an adequate number of functional units, (3) select the appropriate retainers, and (4) apply the best technique for framework processing and veneering.

  17. Occurrence and antimicrobial susceptibility of enteric rods and pseudomonads isolated from the dental prostheses biofilm

    Directory of Open Access Journals (Sweden)

    Sanrrangers Sales Silva

    Full Text Available ABSTRACT Aspiration of oral bacteria leads to cardiac and respiratory infectious diseases and dentures can act as a reservoir for pathogenic microorganisms. Objective: To determine the occurrence and the in vitro antimicrobial susceptibility of enteric rods and pseudomonads from the denture biofilm of 52 subjects at the Center for Dental Specialties of Sobral/ Ceara, Brazil. Material and Methods: Denture biofilm was collected and samples plated on MacConkey agar. The isolated bacterial colonies were identified using the BBL Crystal enteric/non-fermenter system. Antibiotic bacterial susceptibility was assessed by the disc diffusion method of amoxicillin, amoxicillin/clavulanic acid, doxycycline, tetracycline, tobramycin, imipenem, cefotaxime, and ciprofloxacin. The Minimum Inhibitory Concentration (MIC of cefotaxime, tobramycin, doxycycline, imipenem, and ciprofloxacin was determined for 40 species by E-test. Results: 34 subjects (65.4% harbored enteric rods in their prostheses. Klebsiella pneumoniae (26.5%, Escherichia coli (23.5%, and Enterobacter aerogenes (23.5% were the most prevalent species. All organisms were susceptible to ciprofloxacin and most species were resistant to amoxicillin or amoxicillin/clavulanic acid, demonstrating variable sensitivity patterns to other antimicrobials. However, the MIC showed the emergence of strains with reduced sensitivity to ciprofloxacin (MIC90≥3 μg/ mL and cefotaxime (MIC90≥2 μg/mL. Conclusion: The findings show high prevalence of nosocomial diseases-related bacterial species and low susceptibility to antimicrobial drugs. Therefore, these results imply caution against the indiscriminate use of broad spectrum antibiotics in dental practice.

  18. Systematic Review of Ossicular Chain Anatomy: Strategic Planning for Development of Novel Middle Ear Prostheses.

    Science.gov (United States)

    Kamrava, Brandon; Roehm, Pamela C

    2017-08-01

    Objective To systematically review the anatomy of the ossicular chain. Data Sources Google Scholar, PubMed, and otologic textbooks. Review Methods A systematic literature search was performed on January 26, 2015. Search terms used to discover articles consisted of combinations of 2 keywords. One keyword from both groups was used: [ ossicular, ossicle, malleus, incus, stapes] and [ morphology, morphometric, anatomy, variation, physiology], yielding more than 50,000 hits. Articles were then screened by title and abstract if they did not contain information relevant to human ossicular chain anatomy. In addition to this search, references of selected articles were studied as well as suggested relevant articles from publication databases. Standard otologic textbooks were screened using the search criteria. Results Thirty-three sources were selected for use in this review. From these studies, data on the composition, physiology, morphology, and morphometrics were acquired. In addition, any correlations or lack of correlations between features of the ossicular chain and other features of the ossicular chain or patient were noted, with bilateral symmetry between ossicles being the only important correlation reported. Conclusion There was significant variation in all dimensions of each ossicle between individuals, given that degree of variation, custom fitting, or custom manufacturing of prostheses for each patient could optimize prosthesis fit. From published data, an accurate 3-dimensional model of the malleus, incus, and stapes can be created, which can then be further modified for each patient's individual anatomy.

  19. Articulating spacers used in two-stage revision of infected hip and knee prostheses abrade with time.

    Science.gov (United States)

    Fink, Bernd; Rechtenbach, Annett; Büchner, Hubert; Vogt, Sebastian; Hahn, Michael

    2011-04-01

    Articulating spacers used in two-stage revision surgery of infected prostheses have the potential to abrade and subsequently induce third-body wear of the new prosthesis. We asked whether particulate material abraded from spacers could be detected in the synovial membrane 6 weeks after implantation when the spacers were removed for the second stage of the revision. Sixteen hip spacers (cemented prosthesis stem articulating with a cement cup) and four knee spacers (customized mobile cement spacers) were explanted 6 weeks after implantation and the synovial membranes were removed at the same time. The membranes were examined by xray fluorescence spectroscopy, xray diffraction for the presence of abraded particles originating from the spacer material, and analyzed in a semiquantitative manner by inductively coupled plasma mass spectrometry. Histologic analyses also were performed. We found zirconium dioxide in substantial amounts in all samples, and in the specimens of the hip synovial lining, we detected particles that originated from the metal heads of the spacers. Histologically, zirconium oxide particles were seen in the synovial membrane of every spacer and bone cement particles in one knee and two hip spacers. The observations suggest cement spacers do abrade within 6 weeks. Given the presence of abrasion debris, we recommend total synovectomy and extensive lavage during the second-stage reimplantation surgery to minimize the number of abraded particles and any retained bacteria.

  20. Marginal and Internal Fit of Cobalt-Chromium Fixed Dental Prostheses Generated from Digital and Conventional Impressions

    Directory of Open Access Journals (Sweden)

    Per Svanborg

    2014-01-01

    Full Text Available Objectives. Digital impressions are increasingly used and have the potential to avoid the problem of inaccurate impressions. Only a few studies to verify the accuracy of digital impressions have been performed. The purpose of this study was to compare the marginal and internal fit of 3-unit tooth supported fixed dental prostheses (FDPs fabricated from digital and conventional impressions. Methods. Ten FDPs were produced from digital impressions using the iTero system and 10 FDPs were produced using vinyl polysiloxane (VPS impression material. A triple-scan protocol and CAD software were used for measuring and calculating discrepancies of the FDPs at 3 standard areas: mean internal discrepancy, absolute marginal gap, and cervical area discrepancy. The Mann-Whitney U test was used for analyzing the results. Results. For conventional and digital impressions, respectively, FDPs had an absolute marginal gap of 147 μm and 142 μm, cervical area discrepancy of 69 μm and 44 μm, and mean internal discrepancy of 117 μm and 93 μm. The differences were statistically significant in the cervical and internal areas (P<0.001. Significance. The results indicated that the digital impression technique is more exact and can generate 3-unit FDPs with a significantly closer fit compared to the VPS technique.

  1. Ranking of CT in persistent vertigo after implantation of stapes prostheses; Stellenwert der Computertomographie bei persistierenden Gleichgewichtsstoerungen nach dem Einsatz von Stapesplastiken

    Energy Technology Data Exchange (ETDEWEB)

    Koesling, S. [Leipzig Univ. (Germany). Klinik fuer Diagnostische Radiologie; Woldag, K. [Leipzig Univ. (Germany). Klinik und Poliklinik fuer Hals-Nasen-Ohren-Krankheiten; Meister, E.F. [Leipzig Univ. (Germany). Klinik und Poliklinik fuer Hals-Nasen-Ohren-Krankheiten; Reschke, I. [Leipzig Univ. (Germany). Klinik fuer Diagnostische Radiologie; Schulz, H.G. [Leipzig Univ. (Germany). Klinik fuer Diagnostische Radiologie

    1995-01-01

    10 of 150 patients had persistent vertigo after implanation of stapes prostheses. These patients were evaluated by high resolution CT in the axial and coronal plane. Scans showed in all cases findings which related to the symptoms. The CT findings were proved intraoperatively in 9 cases. A new indirect sign of a perilymphatic fistula is described in form of an air bulla at the end of the prosthesis. Retympanotomy could be planned better with the help of HR-CT. (orig.) [Deutsch] Von 150 Patienten zeigten 10 nach dem Einsatz einer Stapesprothese eine persistierende vestibulaere Symptomatik. Mittels der hochaufloesenden Felsenbein-CT in axialer und koronarer Schnittfuehrung konnten in allen Faellen in Symptomatik erklaerende Befunde erhoben werden. Eine operative Bestaetigung erfolgte in 9 Faellen. Als bisher in der Literatur in diesem Zusammenhang nicht beschriebenes, indirektes Zeichen einer Perilymphfistel wurde eine kleine Luftblase am Prothesenende nachgewiesen. Die HR-CT hat sich als wesentliche Erleichterung bei der Planung einer Retympanotomie erwiesen. (orig.)

  2. A fractographic study of clinically retrieved zirconia–ceramic and metal–ceramic fixed dental prostheses

    Science.gov (United States)

    Pang, Zhen; Chughtai, Asima; Sailer, Irena; Zhang, Yu

    2015-01-01

    Objectives A recent 3-year randomized controlled trial (RCT) of tooth supported three- to five-unit zirconia–ceramic and metal–ceramic posterior fixed dental prostheses (FDPs) revealed that veneer chipping and fracture in zirconia–ceramic systems occurred more frequently than those in metal–ceramic systems [1]. This study seeks to elucidate the underlying mechanisms responsible for the fracture phenomena observed in this RCT using a descriptive fractographic analysis. Methods Vinyl-polysiloxane impressions of 12 zirconia–ceramic and 6 metal–ceramic FDPs with veneer fractures were taken from the patients at the end of a mean observation of 40.3 ± 2.8 months. Epoxy replicas were produced from these impressions [1]. All replicas were gold coated, and inspected under the optical microscope and scanning electron microscope (SEM) for descriptive fractography. Results Among the 12 zirconia–ceramic FDPs, 2 had small chippings, 9 had large chippings, and 1 exhibited delamination. Out of 6 metal–ceramic FDPs, 5 had small chippings and 1 had large chipping. Descriptive fractographic analysis based on SEM observations revealed that fracture initiated from the wear facet at the occlusal surface in all cases, irrespective of the type of restoration. Significance Zirconia–ceramic and metal–ceramic FDPs all fractured from microcracks that emanated from occlusal wear facets. The relatively low fracture toughness and high residual tensile stress in porcelain veneer of zirconia restorations may contribute to the higher chipping rate and larger chip size in zirconia–ceramic FDPs relative to their metal–ceramic counterparts. The low veneer/core interfacial fracture energy of porcelain-veneered zirconia may result in the occurrence of delamination in zirconia–ceramic FDPs. PMID:26233469

  3. An evaluation of marginal fit of three-unit fixed dental prostheses fabricated by direct metal laser sintering system.

    Science.gov (United States)

    Kim, Ki-Baek; Kim, Woong-Chul; Kim, Hae-Young; Kim, Ji-Hwan

    2013-07-01

    This in vitro study aimed to evaluate and compare marginal fit of three-unit fixed dental prostheses (FDPs) fabricated using a newly developed direct metal laser sintering (DMLS) system with that of three-unit FDPs by a conventional lost wax technique (LW) method. Ten cobalt-chromium alloy three-unit FDPs using DMLS system and another ten nickel-chromium alloy FDPs using LW method were fabricated. Marginal fit was examined using a light-body silicone. After setting, the silicon film was cut into four parts and the thickness of silicon layer was measured at 160× magnification using a digital microscope to measure absolute marginal discrepancy (AMD), marginal gap (MG) and internal gap (IG). A repeated measure ANOVA for statistical analysis was performed using the SPSS statistical package version 12.0 (α=0.05). The mean values of AMD, MG, and IG were significantly larger in the DMLS group than in the LW group (p0.05). The marginal fit of the DMLS system appeared significantly inferior compared to that of the conventional LW method and slightly larger than the acceptable range. For clinical application further improvement of DMLS system may be required. Copyright © 2013 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.

  4. A new self-administered questionnaire to determine patient experience with voice prostheses (Blom-singer valves

    Directory of Open Access Journals (Sweden)

    Kazi R

    2005-01-01

    Full Text Available Aim: To obtain information about valved speech and related issues in patients who have undergone total laryngectomy with the help of a new structured questionnaire on voice prosthesis. Settings and Design: A questionnaire-based pilot study set at a tertiary referral head and neck cancer unit. Materials and Methods: Twenty-five patients using voice prostheses, who showed no signs of recurrence after having undergone total laryngectomy were interviewed with the help of a questionnaire that assessed issues such as voice quality, valve maintenance, leakage, quality of life, humidification and hands-free system over the preceding seven days. The data was analyzed using non-parametric tests (Mann-Whitney and Spearman rank. Results: Twenty-five patients (16 males with a median age of 65 years (IQ range: 59-70 years had been using the prosthesis for a median of 6 years (IQ range: 5-10 years. The majority of the patients (n=20 were fully informed about their valve size and diameter and most were able to remove and replace their own prosthesis. Fourteen patients (60% had leakage-related issues. Women were less satisfied with their voice quality as compared to men. Overall, there appeared to be an improvement in quality of life with the use of the voice prosthesis. Conclusions: The subjects were fairly well informed about their valve and experienced a high level of satisfaction with their voice. This questionnaire serves as a valuable tool for monitoring voice rehabilitation in patients who have undergone laryngectomy.

  5. Dermatitis de contacto por prótesis ortopédicas Contact dermatitis for orthopaedic prostheses

    Directory of Open Access Journals (Sweden)

    C.A. Danielo

    2007-09-01

    Full Text Available Diversas aleaciones son utilizadas en la fabricación de prótesis ortopédicas (ej: titanio, vitalio, etc, dentro de las cuales la más utilizada es la de acero inoxidable. El níquel, parte importante de esta aleación, es capaz de liberarse y provocar sensibilización, desencadenando reacciones cutáneas locales y sistémicas. De los materiales que componen la aleación para formar acero inoxidable, el níquel es el que más frecuentemente se ve implicado en reacciones cutáneas por sensibilidad, en tanto que otros como el cromo y cobalto, la posibilidad de pérdida de material a partir de la prótesis es discutida. Presentamos el caso de una paciente con dermatitis alérgica al níquel con lesiones generalizadas, que aparecieron luego del implante de prótesis ortopédicas de acero inoxidable, dando positivo para níquel sulfato en las pruebas epicutáneas.Several alloys are used in the manufacture of orthopaedics prostheses (ie: titanium, vitalium. Stainless steel is the most frequently used among them. Nickel is an important component of this alloy and may release and provoke sensitivity. Arising local and systemic cutaneous reactions. Nickel is the material composing stainless steel that ordinary is implicated in cutaneous reactions of sensitivity; the role of chrome or cobalt is still uncertain. Our patient is a woman affected of nickel contact dermatitis, with generalized reactions that appear after an implant of a stainless steel orthopaedic prosthesis. Epicutaneous tests were performed, confirming a strong sensitivity to nickel sulphate.

  6. Long-term clinical outcomes and survivorship of press-fit condylar sigma fixed-bearing and mobile-bearing total knee prostheses in the same patients.

    Science.gov (United States)

    Kim, Young-Hoo; Park, Jang-Won; Kim, Jun-Shik; Kulkarni, Sourabh S; Kim, Yoon-Hong

    2014-10-01

    We are aware of no study that has compared press-fit condylar Sigma fixed-bearing and mobile-bearing total knee prostheses in the same patients after more than ten years of follow-up. The purpose of the current study was to compare these two implants with respect to the functional and radiographic results, prevalence of osteolysis, and overall revision rates at a mean of 12.1 years of follow-up. The study consisted of a consecutive series of 444 patients (mean age [and standard deviation], 66.5 ± 7.4 years) who underwent simultaneous bilateral total knee arthroplasty, with one side treated immediately after the other. All of the patients received a press-fit condylar Sigma mobile-bearing prosthesis on one side and a press-fit condylar Sigma fixed-bearing prosthesis on the contralateral side. The minimum duration of follow-up was ten years (mean, 12.1 years; range, ten to thirteen years). At the time of each follow-up visit, the patients were assessed clinically and radiographically. Postoperative total knee scores (95 and 94 points), Western Ontario and McMaster Universities Osteoarthritis Index (19 and 18 points), University of California, Los Angeles activity score (both prostheses, 5 points), range of motion (129° ± 6.3° and 127° ± 6.8°), and radiographic findings did not differ significantly between the press-fit condylar Sigma mobile and fixed-bearing designs at the final follow-up. The prevalence of aseptic loosening (1.4% and 1.8%) did not differ significantly between the mobile and fixed-bearing implant designs. No knee in either group had osteolysis. The estimated survival rate with revision as the end point was 98.2% (95% confidence interval, 91% to 99%) and 97.5% (95% confidence interval, 91% to 99%) at 12.1 years for the mobile and fixed-bearing implant groups, respectively. The results of the present long-term clinical study suggest that excellent clinical and radiographic results were achieved with both the press-fit condylar Sigma mobile and

  7. La influencia de factores sistémicos en el uso de las prótesis totales Influence of systemic factors in use of total prostheses

    Directory of Open Access Journals (Sweden)

    Carolina de Andrade Lima Chaves

    2009-03-01

    Full Text Available Considerando la posible influencia de las enfermedades sistémicas y de los medicamentos utilizados para su tratamiento en la cavidad bucal, el presente estudio se propone realizar una revisión de la literatura sobre el tema, enfatizando la influencia de estos factores en el uso de las prótesis totales (PTs, con el fin de proporcionar al cirujano-dentista un mejor conocimiento científico para la realización de ese tipo de tratamiento rehabilitador.According to the possible influence of systemic diseases and of drugs used for its treatment in buccal cavity, the aim of present study is to carry out a review of literature on this topic, emphasizing on influence of these factors on use of the total prostheses (PTs, allowing to surgeon-dentist a better scientific knowledge to creation of this type of rehabilitation treatment.

  8. Tribology and wear of metal-on-metal hip prostheses: influence of cup angle and head position.

    Science.gov (United States)

    Williams, Sophie; Leslie, Ian; Isaac, Graham; Jin, Zhongmin; Ingham, Eileen; Fisher, John

    2008-08-01

    Clinical studies have indicated that the angular position of the acetabular cup may influence wear in metal-on-metal total hip bearings. A high cup angle in comparison to the anatomical position may lead to the head being constrained by the superior lateral surface and rim of the cup, thus potentially changing the location of the contact zone between the head and the cup. The aim of this study was to test the hypothesis that both a steep cup angle and a lateralized position of the head can increase head contact on the superior rim of the cup, with the consequence of increased wear. Hip-joint simulator studies of metal-on-metal bearings were undertaken with cup angles of 45 degrees and 55 degrees . The femoral head was either aligned to the center of the cup or placed in a position of microlateralization. Wear was measured gravimetrically over 5 million cycles. A steep cup angle of 55 degrees showed significantly higher long-term steady-state wear than a standard cup angle of 45 degrees (p < 0.01). The difference was fivefold. Microlateralization of the head resulted in a fivefold increase in steady-state wear compared with a centralized head. The combination of a steep cup angle and a microlateralized head increased the steady-state wear rate by tenfold compared with a standard cup angle with a centralized head. These studies support the hypothesis that both an increased cup angle and a lateral head position increase wear in metal-on-metal hip prostheses.

  9. Reliability and failure modes of implant-supported zirconium-oxide fixed dental prostheses related to veneering techniques

    Science.gov (United States)

    Baldassarri, Marta; Zhang, Yu; Thompson, Van P.; Rekow, Elizabeth D.; Stappert, Christian F. J.

    2011-01-01

    Summary Objectives To compare fatigue failure modes and reliability of hand-veneered and over-pressed implant-supported three-unit zirconium-oxide fixed-dental-prostheses(FDPs). Methods Sixty-four custom-made zirconium-oxide abutments (n=32/group) and thirty-two zirconium-oxide FDP-frameworks were CAD/CAM manufactured. Frameworks were veneered with hand-built up or over-pressed porcelain (n=16/group). Step-stress-accelerated-life-testing (SSALT) was performed in water applying a distributed contact load at the buccal cusp-pontic-area. Post failure examinations were carried out using optical (polarized-reflected-light) and scanning electron microscopy (SEM) to visualize crack propagation and failure modes. Reliability was compared using cumulative-damage step-stress analysis (Alta-7-Pro, Reliasoft). Results Crack propagation was observed in the veneering porcelain during fatigue. The majority of zirconium-oxide FDPs demonstrated porcelain chipping as the dominant failure mode. Nevertheless, fracture of the zirconium-oxide frameworks was also observed. Over-pressed FDPs failed earlier at a mean failure load of 696 ± 149 N relative to hand-veneered at 882 ± 61 N (profile I). Weibull-stress-number of cycles-unreliability-curves were generated. The reliability (2-sided at 90% confidence bounds) for a 400N load at 100K cycles indicated values of 0.84 (0.98-0.24) for the hand-veneered FDPs and 0.50 (0.82-0.09) for their over-pressed counterparts. Conclusions Both zirconium-oxide FDP systems were resistant under accelerated-life-time-testing. Over-pressed specimens were more susceptible to fatigue loading with earlier veneer chipping. PMID:21557985

  10. Biotribological behavior of Ag-ZrCxN1-x coatings against UHMWPE for joint prostheses devices.

    Science.gov (United States)

    Calderon V, S; Sánchez-López, J C; Cavaleiro, A; Carvalho, S

    2015-01-01

    This study aims to evaluate the structural, mechanical and tribological properties of zirconium carbonitrides (ZrCxN1-x) coatings with embedded silver nanoparticles, produced with the intention of achieving a material with enhanced multi-functional properties, including mechanical strength, corrosion resistance, tribological performance and antibacterial behavior suitable for their use in joint prostheses. The coatings were deposited by direct current (DC) reactive magnetron sputtering onto 316 L stainless steel, changing the silver content from 0 to 20 at% by modifying the current density applied to the targets. Different nitrogen and acetylene gas fluxes were used as reactive gases. The coatings revealed different mixtures of crystalline ZrCxN1-x, silver nanoparticles and amorphous carbon phases. The hardness of the films was found to be mainly controlled by the ratio between the hard (ZrCxN1-x) and soft (Ag and amorphous carbon) phases in the films, fluctuating between 7.4 and 20.4 GPa. The coefficient of friction, measured against ultra-high molecular weight polyethylene (UHMWPE) in Hank's balanced salt solution with 10 gL(-1) albumin, is governed by the surface roughness and hardness. The UHMWPE wear rates were in the same order of magnitude (between 1.4 and 2.0 × 10(-6)mm(3)N(-1)m(-1)), justified by the effect of the protective layer of albumin formed during the tests. The small differences were due to the hydrophobic/hydrophilic character of the surface, as well as to the silver content. Copyright © 2014 Elsevier Ltd. All rights reserved.

  11. Effect of different types of prosthetic platforms on stress-distribution in dental implant-supported prostheses

    Energy Technology Data Exchange (ETDEWEB)

    Minatel, Lurian [Pró-Reitoria de Pesquisa e Pós-graduação (PRPPG), Universidade do Sagrado Coração, USC, 10–50 Irmã Armindal, Jardim Brasil, Bauru, 17011–160, SP (Brazil); Verri, Fellippo Ramos [Department of Dental Materials and Prosthodontics, Araçatuba Dental School, UNESP - Univ Estadual Paulista, 1193 José Bonifácio Street, Vila Mendonça, Araçatuba 16015–050 (Brazil); Kudo, Guilherme Abu Halawa [Pró-Reitoria de Pesquisa e Pós-graduação (PRPPG), Universidade do Sagrado Coração, USC, 10–50 Irmã Armindal, Jardim Brasil, Bauru, 17011–160, SP (Brazil); Faria Almeida, Daniel Augusto de; Souza Batista, Victor Eduardo de; Aparecido Araujo Lemos, Cleidiel; Piza Pellizzer, Eduardo [Department of Dental Materials and Prosthodontics, Araçatuba Dental School, UNESP - Univ Estadual Paulista, 1193 José Bonifácio Street, Vila Mendonça, Araçatuba 16015–050 (Brazil); and others

    2017-02-01

    A biomechanical analysis of different types of implant connections is relevant to clinical practice because it may impact the longevity of the rehabilitation treatment. Therefore, the objective of this study is to evaluate the Morse taper connections and the stress distribution of structures associated with the platform switching (PSW) concept. It will do this by obtaining data on the biomechanical behavior of the main structure in relation to the dental implant using the 3-dimensional finite element methodology. Four models were simulated (with each containing a single prosthesis over the implant) in the molar region, with the following specifications: M1 and M2 is an external hexagonal implant on a regular platform; M3 is an external hexagonal implant using PSW concept; and M4 is a Morse taper implant. The modeling process involved the use of images from InVesalius CT (computed tomography) processing software, which were refined using Rhinoceros 4.0 and SolidWorks 2011 CAD software. The models were then exported into the finite element program (FEMAP 11.0) to configure the meshes. The models were processed using NeiNastram software. The main results are that M1 (regular diameter 4 mm) had the highest stress concentration area and highest microstrain concentration for bone tissue, dental implants, and the retaining screw (P < 0.05). Using the PSW concept increases the area of the stress concentrations in the retaining screw (P < 0.05) more than in the regular platform implant. It was concluded that the increase in diameter is beneficial for stress distribution and that the PSW concept had higher stress concentrations in the retaining screw and the crown compared to the regular platform implant. - Highlights: • The external hexagon implants was unfavorable biomechanical. • The Morse taper implant presented the best biomechanical result. • Platform switching concept increased stress in screw-retained prostheses.

  12. An approach for brain-controlled prostheses based on Scene Graph Steady-State Visual Evoked Potentials.

    Science.gov (United States)

    Li, Rui; Zhang, Xiaodong; Li, Hanzhe; Zhang, Liming; Lu, Zhufeng; Chen, Jiangcheng

    2018-08-01

    Brain control technology can restore communication between the brain and a prosthesis, and choosing a Brain-Computer Interface (BCI) paradigm to evoke electroencephalogram (EEG) signals is an essential step for developing this technology. In this paper, the Scene Graph paradigm used for controlling prostheses was proposed; this paradigm is based on Steady-State Visual Evoked Potentials (SSVEPs) regarding the Scene Graph of a subject's intention. A mathematic model was built to predict SSVEPs evoked by the proposed paradigm and a sinusoidal stimulation method was used to present the Scene Graph stimulus to elicit SSVEPs from subjects. Then, a 2-degree of freedom (2-DOF) brain-controlled prosthesis system was constructed to validate the performance of the Scene Graph-SSVEP (SG-SSVEP)-based BCI. The classification of SG-SSVEPs was detected via the Canonical Correlation Analysis (CCA) approach. To assess the efficiency of proposed BCI system, the performances of traditional SSVEP-BCI system were compared. Experimental results from six subjects suggested that the proposed system effectively enhanced the SSVEP responses, decreased the degradation of SSVEP strength and reduced the visual fatigue in comparison with the traditional SSVEP-BCI system. The average signal to noise ratio (SNR) of SG-SSVEP was 6.31 ± 2.64 dB, versus 3.38 ± 0.78 dB of traditional-SSVEP. In addition, the proposed system achieved good performances in prosthesis control. The average accuracy was 94.58% ± 7.05%, and the corresponding high information transfer rate (IRT) was 19.55 ± 3.07 bit/min. The experimental results revealed that the SG-SSVEP based BCI system achieves the good performance and improved the stability relative to the conventional approach. Copyright © 2018 Elsevier B.V. All rights reserved.

  13. Detection of total hip prostheses at airport security checkpoints: how has heightened security affected patients?

    Science.gov (United States)

    Johnson, Aaron J; Naziri, Qais; Hooper, Hasan A; Mont, Michael A

    2012-04-04

    The sensitivity of airport security screening measures has increased substantially during the past decade, but few reports have examined how this affects patients who have undergone hip arthroplasty. The purpose of this study was to determine the experiences of patients who had hip prostheses and who passed through airport security screenings. A consecutive series of 250 patients who presented to the office of a high-volume surgeon were asked whether they had had a hip prosthesis for at least one year and, if so, whether they had flown on a commercial airline within the past year. Patients who responded affirmatively to both questions were asked to complete a written survey that included questions about which joint(s) had been replaced, the number of encounters with airport security, the frequency and location of metal detector activation, any additional screening procedures that were utilized, whether security officials requested documentation regarding the prosthesis, the degree of inconvenience, and other relevant information. Of the 143 patients with hip replacements who traveled by air, 120 (84%) reported triggering the alarm and required wanding with a handheld detector. Twenty-five of these patients reported subsequently having to undergo further inspection, including additional wanding, being patted down, and in two cases having to undress in a private room to show the incision. Ninety-nine (69%) of the 143 patients reported that the prosthetic joint caused an inconvenience while traveling. This study provides interesting and critical information that allows physicians to understand the real-world implications of implanted orthopaedic devices for patients who are traveling where there has been heightened security since September 11, 2001. Patients should be counseled that they should expect delays and be prepared for such inconveniences, but that these are often only momentary. This information could relieve some anxiety and concerns that patients may have

  14. Effect of different types of prosthetic platforms on stress-distribution in dental implant-supported prostheses

    International Nuclear Information System (INIS)

    Minatel, Lurian; Verri, Fellippo Ramos; Kudo, Guilherme Abu Halawa; Faria Almeida, Daniel Augusto de; Souza Batista, Victor Eduardo de; Aparecido Araujo Lemos, Cleidiel; Piza Pellizzer, Eduardo

    2017-01-01

    A biomechanical analysis of different types of implant connections is relevant to clinical practice because it may impact the longevity of the rehabilitation treatment. Therefore, the objective of this study is to evaluate the Morse taper connections and the stress distribution of structures associated with the platform switching (PSW) concept. It will do this by obtaining data on the biomechanical behavior of the main structure in relation to the dental implant using the 3-dimensional finite element methodology. Four models were simulated (with each containing a single prosthesis over the implant) in the molar region, with the following specifications: M1 and M2 is an external hexagonal implant on a regular platform; M3 is an external hexagonal implant using PSW concept; and M4 is a Morse taper implant. The modeling process involved the use of images from InVesalius CT (computed tomography) processing software, which were refined using Rhinoceros 4.0 and SolidWorks 2011 CAD software. The models were then exported into the finite element program (FEMAP 11.0) to configure the meshes. The models were processed using NeiNastram software. The main results are that M1 (regular diameter 4 mm) had the highest stress concentration area and highest microstrain concentration for bone tissue, dental implants, and the retaining screw (P < 0.05). Using the PSW concept increases the area of the stress concentrations in the retaining screw (P < 0.05) more than in the regular platform implant. It was concluded that the increase in diameter is beneficial for stress distribution and that the PSW concept had higher stress concentrations in the retaining screw and the crown compared to the regular platform implant. - Highlights: • The external hexagon implants was unfavorable biomechanical. • The Morse taper implant presented the best biomechanical result. • Platform switching concept increased stress in screw-retained prostheses.

  15. Multicriteria Decision Analysis in Improving Quality of Design in Femoral Component of Knee Prostheses: Influence of Interface Geometry and Material

    Directory of Open Access Journals (Sweden)

    Ali Jahan

    2015-01-01

    Full Text Available Knee prostheses as medical products require careful application of quality and design tool to ensure the best performance. Therefore, quality function deployment (QFD was proposed as a quality tool to systematically integrate consumer’s expectation to perceived needs by medical and design team and to explicitly address the translation of customer needs into engineering characteristics. In this study, full factorial design of experiment (DOE method was accompanied by finite element analysis (FEA to evaluate the effect of inner contours of femoral component on mechanical stability of the implant and biomechanical stresses within the implant components and adjacent bone areas with preservation of the outer contours for standard Co-Cr alloy and a promising functionally graded material (FGM. The ANOVA revealed that the inner shape of femoral component influenced the performance measures in which the angle between the distal and anterior cuts and the angle between the distal and posterior cuts were greatly influential. In the final ranking of alternatives, using multicriteria decision analysis (MCDA, the designs with FGM was ranked first over the Co-Cr femoral component, but the original design with Co-Cr material was not the best choice femoral component, among the top ranked design with the same material.

  16. Cross-cultural validation of the Prosthesis Evaluation Questionnaire in vascular amputees fitted with prostheses in Spain.

    Science.gov (United States)

    Benavent, Jose Vicente; Igual, Celedonia; Mora, Enrique; Antonio, Rosa; Tenias, Jose Maria

    2016-12-01

    The lack of specific prosthetic-related outcome instruments for Spanish amputees must be addressed. To elaborate a culturally equivalent version of the Prosthesis Evaluation Questionnaire in the Spanish language. Cross-cultural questionnaire validation. Two-step process for cultural adaptation: forward and backward translations of English original and Spanish translated versions; assessment of both construct and criterion validity and reliability in a group of vascular amputees. A total of 61 patients were recruited, 44 men (72.1%) and 17 women (27.9%), with a median age of 71.1 years (standard deviation: 7.7 years; range: 51-87 years). In the Prosthesis Evaluation Questionnaire-Spanish, the lowest scores were for gait and frustration, and the highest scores were for noise and stump health. Internal consistency of the questionnaire was acceptable (>0.70) for four of the scales used in the Prosthesis Evaluation Questionnaire but poor (<0.50) for the scales relating to appearance and stump health. Correlations with the quality-of-life levels as measured by the Short Form-36 were positive and mostly significant. Prosthesis Evaluation Questionnaire-Spanish could assess the quality of life in patients who have undergone vascular amputations and then been fitted with a prosthetic limb. The questionnaire shows adequate criteria validity when compared with other instruments for measuring quality of life. The Prosthesis Evaluation Questionnaire-Spanish could be a valid and reliable instrument for assessing adaptation to prostheses in vascular amputees. The questionnaire adds information relevant to the patient and the physician and may identify cases with poor expected adaptation to the prosthesis. © The International Society for Prosthetics and Orthotics 2015.

  17. Lower layers in the motor cortex are more effective targets for penetrating microelectrodes in cortical prostheses

    Science.gov (United States)

    Parikh, Hirak; Marzullo, Timothy C.; Kipke, Daryl R.

    2009-04-01

    Improving cortical prostheses requires the development of recording neural interfaces that are efficient in terms of providing maximal control information with minimal interface complexity. While the typical approaches have targeted neurons in the motor cortex with multiple penetrating shanks, an alternative approach is to determine an efficient distribution of electrode sites within the layers of the cortex with fewer penetrating shanks. The objective of this study was to compare unit activity in the upper and lower layers of the cortex with respect to movement and direction in order to inform the design of penetrating microelectrodes. Four rats were implanted bilaterally with multi-site single-shank silicon microelectrode arrays in the neck/shoulder region of the motor cortex. We simultaneously recorded unit activity across all layers of the motor cortex while the animal was engaged in a movement direction task. Localization of the electrode array within the different layers of the cortex was determined by histology. We denoted units from layers 2 and 3 and units as upper layer units, and units from layers 5 and 6 as lower layer units. Analysis of unit spiking activity demonstrated that both the upper and lower layers encode movement and direction information. Unit responses in either cortical layer of the cortex were not preferentially associated with contralateral or ipsilateral movement. Aggregate analysis (633 neurons) and best session analysis (75 neurons) indicated that units in the lower layers (layers 5, 6) are more likely to encode direction information when compared to units in the upper layers (layers 2, 3) (p< 0.05). These results suggest that electrode sites clustered in the lower layers provide access to more salient control information for cortical neuroprostheses.

  18. The essential oil of Allium sativum as an alternative agent against Candida isolated from dental prostheses.

    Science.gov (United States)

    Mendoza-Juache, Alejandro; Aranda-Romo, Saray; Bermeo-Escalona, Josué R; Gómez-Hernández, Araceli; Pozos-Guillén, Amaury; Sánchez-Vargas, Luis Octavio

    The colonization of the surfaces of dental prostheses by Candida albicans is associated with the development of denture stomatitis. In this context, the use of fluconazole has been proposed, but its disadvantage is microbial resistance. Meanwhile, the oil of Allium sativum has shown an effect in controlling biofilm formation by C. albicans. The objective of this study was to determine the antifungal activities of the essential oil of A. sativum and fluconazole against clinical isolates of Candida species obtained from rigid, acrylic-based partial or total dentures and to compare these agents' effects on both biofilm and planktonic cells. A total of 48 clinical isolates obtained from the acrylic surface of partial or complete dentures were examined, and the following species were identified: C. albicans, Candida glabrata, Candida tropicalis, and Candida krusei. For each isolate, the antifungal activities of the essential oil of A. sativum and fluconazole against both biofilm and planktonic cells were evaluated using the Clinical & Laboratory Standards Institute (CLSI) M27-A3 method. The isolates were also evaluated by semiquantitative XTT reduction. All planktonic Candida isolates were susceptible to the essential oil of A. sativum, whereas 4.2% were resistant to fluconazole. Regarding susceptibilities in biofilms, 43.8% of biofilms were resistant to A. sativum oil, and 91.7% were resistant to fluconazole. All planktonic cells of the different Candida species tested are susceptible to sativum oil, and the majority are susceptible to fluconazole. Susceptibility decreases in biofilm cells, with increased resistance to fluconazole compared with A. sativum oil. The essential oil of A. sativum is thus active against clinical isolates of Candida species obtained from dentures, with effects on both biofilm and planktonic cells in vitro. Copyright © 2017 Asociación Española de Micología. Publicado por Elsevier España, S.L.U. All rights reserved.

  19. Current state of craniofacial prosthetic rehabilitation.

    Science.gov (United States)

    Ariani, Nina; Visser, Anita; van Oort, Robert P; Kusdhany, Lindawati; Rahardjo, Tri Budi W; Krom, Bastiaan P; van der Mei, Henry C; Vissink, Arjan

    2013-01-01

    This study aimed to review the current state of the techniques and materials used to rehabilitate maxillofacial defects. The MEDLINE and EMBASE databases were searched for articles pertinent to maxillofacial prostheses published from January 1990 to July 2011. The main clinical stages were the subject of analysis. A multidisciplinary approach is preferred when rehabilitating maxillofacial defects. Surgical reconstruction can be used for smaller defects, but larger defects require a prosthesis to achieve an esthetic rehabilitation. Implant retained prostheses are preferred over adhesive prostheses. Silicone elastomer is currently the best material available for maxillofacial prostheses; however, longevity and discoloration, which are greatly influenced by ultraviolet radiation, microorganisms, and environmental factors, remain significant problems. In the near future, the widespread availability and cost effectiveness of digital systems may improve the workflow and outcomes of facial prostheses. Patients report high satisfaction with their prostheses despite some areas that still need improvement. Maxillofacial prostheses are a reliable treatment option to restore maxillofacial defects and improve quality of life. Significant progress has been made in the application of implants for retention and digital technology for designing surgical guides, suprastructures, and craniofacial prostheses. Further improvements are necessary to enhance longevity of prostheses.

  20. Veneered zirconia inlay-retained fixed dental prostheses: 10-Year results from a prospective clinical study.

    Science.gov (United States)

    Rathmann, Friederike; Bömicke, Wolfgang; Rammelsberg, Peter; Ohlmann, Brigitte

    2017-09-01

    The purpose of this study was to evaluate the 10-year clinical performance of zirconia-based inlay-retained fixed dental prostheses (IRFDP). For replacement of a molar in 27 patients, 30 IRFDP were luted by use of different cements, Panavia F (Kuraray Europe GmbH) or Multilink Automix (Ivoclar Vivadent GmbH), with use of inlay/inlay, inlay/full-crown, or inlay/partial-crown retainers for anchorage. Frameworks were milled from yttria-stabilized zirconia (IPS e.maxZirCAD; Ivoclar Vivadent GmbH) and fully veneered with pressable ceramic (IPS e.max ZirPress; Ivoclar Vivadent GmbH). Before luting, the IRFDP were silica-coated (Rocatec; 3M Espe) and silanized (Monobond S; Ivoclar Vivadent GmbH). Complications (for example, chipping or delamination of the veneering ceramic, debonding, secondary caries, endodontic treatment, and abutment tooth fracture) and failure were reported, by use of standardized report forms, 2 weeks, 6 months, and 1, 2, and 10 years after cementation. Statistical analysis included Kaplan-Meier survival and success (complication-free survival) and Cox regression analysis (α=0.05 for all). During the 10-year observation period, the complications most often observed were chipping of the veneer and debonding. Twenty-five restorations failed and one participant dropped out. Cumulative 10-year survival and success were 12.1% and 0%, respectively. The design of the retainer, use of a dental dam, choice of cement, and location in the dental arch had no statistically significant effect on the occurrence of complications. Use of fully veneered zirconia-based IRFDP with this technique cannot be recommended. A large incidence of complications and poor survival were observed for fully veneered zirconia-based IRFDP, revealing an urgent need for further design improvements for this type of restoration. This, again, emphasizes the need for testing of new restoration designs in clinical trials before implementation in general dental practice. Copyright © 2017

  1. Passive prosthetic hands and tools: A literature review.

    Science.gov (United States)

    Maat, Bartjan; Smit, Gerwin; Plettenburg, Dick; Breedveld, Paul

    2018-02-01

    The group of passive prostheses consists of prosthetic hands and prosthetic tools. These can either be static or adjustable. Limited research and development on passive prostheses has been performed although many people use these prosthesis types. Although some publications describe passive prostheses, no recent review of the peer-reviewed literature on passive prostheses is available. Review the peer-reviewed literature on passive prostheses for replacement of the hand. Literature review. Four electronic databases were searched using a Boolean combination of relevant keywords. English-language articles relevant to the objective were selected. In all, 38 papers were included in the review. Publications on passive prosthetic hands describe their users, usage, functionality, and problems in activities of daily living. Publications on prosthetic tools mostly focus on sport, recreation, and vehicle driving. Passive hand prostheses receive little attention in prosthetic research and literature. Yet one out of three people with a limb deficiency uses this type of prosthesis. Literature indicates that passive prostheses can be improved on pulling and grasping functions. In the literature, ambiguous names are used for different types of passive prostheses. This causes confusion. We present a new and clear classification of passive prostheses. Clinical relevance This review provides information on the users of passive prosthetic hands and tools, their usage and the functionality. Passive prostheses receive very little attention and low appreciation in literature. Passive prosthetic hands and tools show to be useful to many unilateral amputees and should receive more attention and higher acceptance.

  2. Mechanistic and morphological origins of ultra-high molecular weight polyethylene wear debris in total joint replacement prostheses.

    Science.gov (United States)

    Wang, A; Stark, C; Dumbleton, J H

    1996-01-01

    The mechanistic and morphological origins of microscopic wear debris generated from UHMWPE articular surfaces in total joint replacement prostheses are investigated in this study. It was found experimentally that the molecular chain structure at the articulating surface of UHMWPE undergoes a re-organization process due to strain accumulation caused by surface traction. This molecular re-organization process creates a fibre-like surface texture that exhibits an anisotropic behaviour similar to a unidirectionally reinforced polymer composite. This composite responds to stresses favourably if loaded along the fibre axis but unfavourably if loaded off axis. Due to the very complex multi-axial motion/loading nature at the articular surfaces in total joint replacements, the stress tensors applied to each localized asperity contact area continuously change their directions and magnitudes. These changes in the localized stress field create an off-axis loading situation at each localized contact zone with respect to the orientation of the molecular chains. Depending on the off-axis angle, failure of the molecular structure occurs in three different ways: tensile rupture at very small off-axis angles, shear rupture at intermediate off-axis angles and transverse splitting at large off-axis angles. These failure mechanisms all produce similar fibre-like wear debris. However, the failure stresses differ significantly among the three modes. According to this molecular wear theory, the preferred polymer microstructure for optimal wear resistance would be a three-dimensionally strong network connected by covalent bonds between molecular chains. For UHMWPE, a three-dimensional molecular network can be created by radiation induced cross-linking. Experiments conducted on both gamma irradiated and unirradiated UHMWPE specimens using a linear wear machine and multi-axial joint simulators confirmed the validity of the molecular wear theory.

  3. Comparison of Treatment Outcomes in Partially Edentulous Patients with Implant-Supported Fixed Prostheses and Removable Partial Dentures.

    Science.gov (United States)

    Nogawa, Toshifumi; Takayama, Yoshiyuki; Ishida, Keita; Yokoyama, Atsuro

    The aim of this study was to compare masticatory performance, occlusal force, and oral health-related quality of life (OHRQoL) in patients with mandibular distal-extension edentulism between those with implant-supported fixed prostheses (ISFPs) and those with removable partial dentures (RPDs), and to evaluate relationships among them. Subjects were recruited from patients using ISFPs or RPDs for mandibular distal-extension edentulism. Masticatory performance was evaluated based on the glucose extracted from chewed gummy jelly. Occlusal force was measured with a pressure-sensitive sheet, and data were subjected to computer analysis. The Japanese version of the Oral Health Impact Profile (OHIP-J) was used to evaluate OHRQoL. The masticatory performance, occlusal force, and OHIP-J scores of the ISFP and RPD groups were compared using the Wilcoxon rank-sum test. The relationships among the variables were analyzed using the Spearman rank correlation coefficient test. Multivariate logistic regression analysis was employed with the OHIP-J score as a dependent variable. Nineteen patients with ISFPs and 25 patients with RPDs participated in this study. No significant difference was observed between the two groups with regard to masticatory performance and occlusal force. The OHIP-J score was significantly lower in the ISFP group than in the RPD group. The OHIP-J score had no significant correlation with masticatory performance, but was significantly correlated with occlusal force and the prosthetic method. Multivariate logistic regression analysis showed that younger age, RPDs, and lower occlusal force were significantly associated with a higher OHIP-J summary score. The present results suggest that the difference in masticatory performance and occlusal force between ISFPs and RPDs is small, but ISFPs are superior to RPDs with regard to OHRQoL in patients with mandibular distal-extension edentulism. In addition, there appears to be a slight correlation between the OHIP

  4. Influence of retainer design on two-unit cantilever resin-bonded glass fiber reinforced composite fixed dental prostheses: an in vitro and finite element analysis study.

    Science.gov (United States)

    Keulemans, Filip; De Jager, Niek; Kleverlaan, Cornelis J; Feilzer, Albert J

    2008-10-01

    The aim of this study was to evaluate in vitro the influence of retainer design on the strength of two-unit cantilever resin-bonded glass fiber-reinforced composite (FRC) fixed dental prostheses (FDP). Four retainer designs were tested: a proximal box, a step-box, a dual wing, and a step-box-wing. Of each design on 8 human mandibular molars, FRC-FDPs of a premolar size were produced. The FRC framework was made of resin impregnated unidirectional glass fibers (Estenia C&B EG Fiber, Kuraray) and veneered with hybrid resin composite (Estenia C&B, Kuraray). Panavia F 2.0 (Kuraray) was used as resin luting cement. FRC-FDPs were loaded to failure in a universal testing machine. One-way ANOVA and Tukey's post-hoc test were used to evaluate the data. The four designs were analyzed with finite element analysis (FEA) to reveal the stress distribution within the tooth/restoration complex. Significantly lower fracture strengths were observed with inlay-retained FDPs (proximal box: 300 +/- 65 N; step-box: 309 +/- 37 N) compared to wing-retained FDPs (p optimal design for replacement of a single premolar by means of a two-unit cantilever FRC-FDPs.

  5. Combination of straight and tilted implants for supporting screw-retained dental prostheses in atrophic posterior maxillae: A 2-year prospective study.

    Science.gov (United States)

    Casar-Espinosa, Juan-Carlos; Castillo-Oyagüe, Raquel; Serrera-Figallo, María Ángeles; Garrido-Serrano, Roberto; Lynch, Christopher D; Menéndez-Collar, Manuel; Torres-Lagares, Daniel; Gutiérrez-Pérez, José-Luis

    2017-08-01

    To evaluate the two-year survival rate (SR) and marginal bone loss (MBL) of fixed dental prostheses (FDPs) supported by straight (S) and tilted (T) implants under the influence of diverse study variables. A prospective investigation comprising 21 patients provided with a total of 27 maxillary screw-retained restorations fixed to 70 dental implants was developed. Two groups of implants were considered depending on their inclination with respect to the occlusal plane: Group 1 (S, n=37): straight/axial implants and Group 2 (T, n=33): tilted/angled fixations. Each FDP was supported by a combination of S and T implants. SR and MBL were assessed at the time of loading and two years after surgery. Patient-, surgical- and/or rehabilitation-related information was gathered. Data were statistically analysed at the α=0.05 significance level. After 24 months, a 100% SR was achieved and the MBL of S and T implants were statistically similar. T implants located in the molar region showed lower MBL than did those replacing premolars (p=0.031). Upright and angled fixations inserted at posterior maxillary areas resulted in comparable survival rates and peri-implant MBL after two years. The marginal bone resorption around tilted implants depended on their location. Screw-retained restorations fixed to straight and tilted implants seem to be a safe treatment option in posterior atrophic maxillae. Copyright © 2017 Elsevier Ltd. All rights reserved.

  6. Hydroxyapatite does not improve the outcome of a bipolar hemiarthroplasty.

    NARCIS (Netherlands)

    Meijerink, H.J.; Gardeniers, J.W.M.; Buma, P.; Lemmens, J.A.M.; Schreurs, B.W.

    2004-01-01

    In a one-surgeon study the clinical and radiographic results of 30 cementless bipolar hip prostheses in 24 patients younger than 55 years were evaluated. Eleven noncoated prostheses (Noncoated Group) and 19 hydroxyapatite-coated prostheses (Hydroxyapatite Group) were compared after a mean followup

  7. Adhesion of yeasts and bacteria to fluoro-alkylsiloxane layers chemisorbed on silicone rubber

    NARCIS (Netherlands)

    Everaert, EPJM; van der Mei, HC; Busscher, HJ

    1998-01-01

    Indwelling voice prostheses are most often made of silicone rubber. However, the silicone rubber surface attracts huge quantities of adhering yeasts and bacteria and their colonization on the valve side of voice prostheses leads to frequent malfunctioning. On average, indwelling voice prostheses

  8. Cost of placement and complications associated with osseointegrated bone-conducting hearing prostheses: a retrospective analysis of medicare billing data.

    Science.gov (United States)

    Pross, Seth E; Layton, Andrew; Tong, Kuo; Lustig, Lawrence R

    2014-03-01

    To report the cost of placement and complications related to osseointegrated bone-conducting hearing prostheses (OBHPs) in a Medicare population. We performed a retrospective analysis of nationwide Medicare claims data for operative and nonoperative complications associated with the placement of percutaneous OBHPs between the first quarter of 2007 and the second quarter of 2009 for which there were 6 subsequent quarters of follow-up. We used Medicare Standard Analytical Files (SAF), which contain a 5% random sample of Medicare fee-for-service beneficiaries, excluding those that also were enrolled in a managed-care organization. We identified 118 patients who had OBHPs placed in the requisite period. Their complication billing data were analyzed for the six-quarters after initial placement. Seventy patients (59%) had no billing codes for complications or repeat procedures after receiving the implant, whereas 48 patients (41%) had such codes. The total adjusted mean cost with repeat/revision operations or complications was $7,812 per patient compared with $6,733 for those without these issues, an increase of $1,079 or 16%. We estimate that complications associated with the implantation of percutaneous OBHPs led to $417,616 in additional costs in the entire Medicare fee-for-service population during the study period and that the total cost of placement of these devices together with the cost of their complications totaled $6,789,248. In conclusion, the Medicare SAF database suggests that complications associated with OBHP increased the overall cost of placement by 16%. Like all surgical procedures, these complications and their associated costs should be taken into account when considering treatment options for patients who experience hearing loss.

  9. Evaluation of metal-polymeric fixed partial prosthesis using optical coherence tomography

    Science.gov (United States)

    Sinescu, C.; Negrutiu, M. L.; Duma, V. F.; Marcauteanu, C.; Topala, F. I.; Rominu, M.; Bradu, A.; Podoleanu, A. Gh.

    2013-11-01

    Metal-Polymeric fixed partial prosthesis is the usual prosthetic treatment for many dental patients. However, during the mastication the polymeric component of the prosthesis is fractured and will be lost. This fracture is caused by the material defects or by the fracture lines trapped inside the esthetic components of the prosthesis. This will finally lead to the failure of the prosthetic treatment. Nowadays, there is no method of identification and forecast for the materials defects of the polymeric materials. The aim of this paper is to demonstrate the capability of Optical Coherence Tomography (OCT) as a non-invasive clinical method that can be used for the evaluation of metal-polymeric fixed partial prostheses. Twenty metal-polymeric fixed partial prostheses were used for this study. The esthetic component of the prostheses has been Adoro (Ivoclar). Optical investigations of the metal prostheses have revealed no material defects or fracture lines. All the prostheses were temporary cemented in the oral cavities of the patients for six month. The non-invasive method used for the investigations was OCT working in Time Domain mode at 1300 nm. The evaluations of the prostheses were performed before and after their cementation in the patient mouths. All the imagistic results were performed in 2D and than in 3D, after the reconstruction. The results obtained after the OCT evaluation allowed for the identification of 4 metal-polymeric fixed partial prostheses with material defects immediately after finishing the technological procedures. After 6 month in the oral environment other 3 fixed partial prostheses revealed fracture lines. In conclusion, OCT proved to be a valuable tool for the noninvasive evaluation of the metal-polymeric fixed partial prostheses.

  10. Precision Fit of Screw-Retained Implant-Supported Fixed Dental Prostheses Fabricated by CAD/CAM, Copy-Milling, and Conventional Methods.

    Science.gov (United States)

    de França, Danilo Gonzaga; Morais, Maria Helena; das Neves, Flávio D; Carreiro, Adriana Fonte; Barbosa, Gustavo As

    The aim of this study was to evaluate the effectiveness of fabrication methods (computer-aided design/computer-aided manufacture [CAD/CAM], copy-milling, and conventional casting) in the fit accuracy of three-unit, screw-retained fixed dental prostheses. Sixteen three-unit implant-supported screw-retained frameworks were fabricated to fit an in vitro model. Eight frameworks were fabricated using the CAD/CAM system, four in zirconia and four in cobalt-chromium. Four zirconia frameworks were fabricated using the copy-milled system, and four were cast in cobalt-chromium using conventional casting with premachined abutments. The vertical and horizontal misfit at the implant-framework interface was measured using scanning electron microscopy at ×250. The results for vertical misfit were analyzed using Kruskal-Wallis and Mann-Whitney tests. The horizontal misfits were categorized as underextended, equally extended, or overextended. Statistical analysis established differences between groups according to the chi-square test (α = .05). The mean vertical misfit was 5.9 ± 3.6 μm for CAD/CAM-fabricated zirconia, 1.2 ± 2.2 μm for CAD/CAM-fabricated cobalt-chromium frameworks, 7.6 ± 9.2 μm for copy-milling-fabricated zirconia frameworks, and 11.8 (9.8) μm for conventionally fabricated frameworks. The Mann-Whitney test revealed significant differences between all but the zirconia-fabricated frameworks. A significant association was observed between the horizontal misfits and the fabrication method. The percentage of horizontal misfits that were underextended and overextended was higher in milled zirconia (83.3%), CAD/CAM cobaltchromium (66.7%), cast cobalt-chromium (58.3%), and CAD/CAM zirconia (33.3%) frameworks. CAD/CAM-fabricated frameworks exhibit better vertical misfit and low variability compared with copy-milled and conventionally fabricated frameworks. The percentage of interfaces equally extended was higher when CAD/CAM and zirconia were used.

  11. Cyclic fatigue and fracture in pyrolytic carbon-coated graphite mechanical heart-valve prostheses: role of small cracks in life prediction.

    Science.gov (United States)

    Dauskardt, R H; Ritchie, R O; Takemoto, J K; Brendzel, A M

    1994-07-01

    A fracture-mechanics based study has performed to characterize the fracture toughness and rates of cyclic fatigue-crack growth of incipient flaws in prosthetic heart-valve components made of pyrolytic carbon-coated graphite. Such data are required to predict the safe structural lifetime of mechanical heart-valve prostheses using damage-tolerant analysis. Unlike previous studies where fatigue-crack propagation data were obtained using through-thickness, long cracks (approximately 2-20 mm long), growing in conventional (e.g., compact-tension) samples, experiments were performed on physically small cracks (approximately 100-600 microns long), initiated on the surface of the pyrolytic-carbon coating to simulate reality. Small-crack toughness results were found to agree closely with those measured conventionally with long cracks. However, similar to well-known observations in metal fatigue, it was found that based on the usual computations of the applied (far-field) driving force in terms of the maximum stress intensity, Kmax, small fatigue cracks grew at rates that exceeded those of long cracks at the same applied stress intensity, and displayed a negative dependency on Kmax; moreover, they grew at applied stress intensities less than the fatigue threshold value, below which long cracks are presumed dormant. To resolve this apparent discrepancy, it is shown that long and small crack results can be normalized, provided growth rates are characterized in terms of the total (near-tip) stress intensity (incorporating, for example, the effect of residual stress); with this achieved, in principle, either form of data can be used for life prediction of implant devices. Inspection of the long and small crack results reveals extensive scatter inherent in both forms of growth-rate data for the pyrolytic-carbon material.

  12. Corrosion of dental magnet attachments for removable prostheses on teeth and implants.

    Science.gov (United States)

    Boeckler, Arne F; Ehring, Carolin; Morton, Dean; Geis-Gerstorfer, Jürgen; Setz, Juergen M

    2009-06-01

    For a long time, the use of magnets for the anchorage of dental prostheses failed due to lack of biocompatibility and the magnets' high susceptibility to corrosion in the mouth. These facts make encapsulation of the magnetic alloy with a corrosion-resistant, tight, and functionally firm sealing necessary. Due to different products and analysis methods, it is not feasible to compare the findings for contemporary products with the sparse and rather old test results in the literature. Therefore, the aim of this study was the standardized control and the comparison of the corrosion behavior of modern magnetic attachments for use on teeth and dental implants. Thirty-seven components of magnetic attachments on implants and natural teeth from different alloys (NdFeB, SmCo, Ti, CrMoMnTiFe, etc.) as delivered by the manufacturers or fabricated according to their instructions were examined for their corrosion behavior using the statical immersion analysis (ISO 10271:2001). Four specimens of every product with the same design were used. An uncased SmCo magnet served as control. Analyses after 1, 4, 7, and 28 days of the storage in corrosion solution were made. The eluate was examined quantitatively on the alloy components of the respective component with the help of optical emission spectrometry (microg/cm(2)). The results were compared to the requirements of ISO standard 22674:2006. In addition, existing corrosion products were also defined in the solution after 28 days. The results were analyzed descriptively and statistically to determine possible significant differences (t-test and Mann-Whitney-Wilcoxon rank-sums test; p keeper), Cr (1.18, Magfit DX 800 keeper), Pd (0.21, Direct System Keeper), Ni (0.18, WR-Magnet S3 small), Co (0.12, Direct System Keeper), and Ti (0.09, Magna Cap - Mini). After 28 days, the analyzed ion release increased non-uniformly: Fe (31.92, Magfit DX 800 Keeper), Cr (6.65, Magfit DX 800 Keeper), Pd (18.19, Direct System Keeper), Ni (0.61, WR

  13. Reverse engineering of mandible and prosthetic framework: Effect of titanium implants in conjunction with titanium milled full arch bridge prostheses on the biomechanics of the mandible.

    Science.gov (United States)

    De Santis, Roberto; Gloria, Antonio; Russo, Teresa; D'Amora, Ugo; Varriale, Angelo; Veltri, Mario; Balleri, Piero; Mollica, Francesco; Riccitiello, Francesco; Ambrosio, Luigi

    2014-12-18

    This study aimed at investigating the effects of titanium implants and different configurations of full-arch prostheses on the biomechanics of edentulous mandibles. Reverse engineered, composite, anisotropic, edentulous mandibles made of a poly(methylmethacrylate) core and a glass fibre reinforced outer shell were rapid prototyped and instrumented with strain gauges. Brånemark implants RP platforms in conjunction with titanium Procera one-piece or two-piece bridges were used to simulate oral rehabilitations. A lateral load through the gonion regions was used to test the biomechanical effects of the rehabilitations. In addition, strains due to misfit of the one-piece titanium bridge were compared to those produced by one-piece cast gold bridges. Milled titanium bridges had a better fit than cast gold bridges. The stress distribution in mandibular bone rehabilitated with a one-piece bridge was more perturbed than that observed with a two-piece bridge. In particular the former induced a stress concentration and stress shielding in the molar and symphysis regions, while for the latter design these stresses were strongly reduced. In conclusion, prosthetic frameworks changed the biomechanics of the mandible as a result of both their design and manufacturing technology. Copyright © 2014 Elsevier Ltd. All rights reserved.

  14. Restoration of vision in blind individuals using bionic devices: a review with a focus on cortical visual prostheses.

    Science.gov (United States)

    Lewis, Philip M; Ackland, Helen M; Lowery, Arthur J; Rosenfeld, Jeffrey V

    2015-01-21

    detail these and other challenges facing developers of cortical visual prostheses in addition to briefly outlining the epidemiology of blindness, and the history of cortical electrical stimulation in the context of visual prosthetics. Copyright © 2014 The Authors. Published by Elsevier B.V. All rights reserved.

  15. Effects of Cement, Abutment Surface Pretreatment, and Artificial Aging on the Force Required to Detach Cantilever Fixed Dental Prostheses from Dental Implants.

    Science.gov (United States)

    Kappel, Stefanie; Chepura, Taras; Schmitter, Marc; Rammelsberg, Peter; Rues, Stefan

    To examine the in vitro effects of different cements, abutment surface preconditioning, and artificial aging on the maximum tensile force needed to detach cantilever fixed dental prostheses (FDPs) from dental implants with titanium abutments. A total of 32 tissue-level implants were combined with standardized titanium abutments. For each test group, eight cantilever FDPs were fabricated using selective laser melting (cobalt-chromium [CoCr] alloy). The inner surfaces of the cantilever FDPs and half of the abutments were sandblasted and then joined by use of four different cements (two permanent and two semi-permanent) in two different amounts per cement. Subgroups were tested after either artificial aging (thermocycling and chewing simulation) or 3 days of water storage. Finally, axial pull off-tests were performed for each abutment separately. Cement type and surface pretreatment significantly affected decementation behavior. The highest retention forces (approximately 1,200 N) were associated with sandblasted abutments and permanent cements. With unconditioned abutments, temporary cements (Fu cement (Fu ≈ 100 N), resulted in rather low retention forces. Zinc phosphate cement guaranteed high retention forces. After aging, retention was sufficient only for cementation with zinc phosphate cement and for the combination of sandblasted abutments and glass-ionomer cement. When glass-ionomer cement is used to fix cantilever FDPs on implants, sandblasting of standard titanium abutments may help prevent loss of retention. Retention forces were still high for FDPs fixed with zinc phosphate cement, even when the abutments were not pretreated. Use of permanent cements only, however, is recommended to prevent unwanted loosening of cantilever FDPs.

  16. Biological aortic valve replacement: advantages and optimal indications of stentless compared to stented valve substitutes. A review.

    Science.gov (United States)

    Tavakoli, Reza; Danial, Pichoy; Oudjana, Ahmed Hamid; Jamshidi, Peiman; Gassmann, Max; Leprince, Pascal; Lebreton, Guillaume

    2018-05-01

    Controversy still surrounds the optimal biological valve substitute for aortic valve replacement. In light of the current literature, we review advantages and optimal indications of stentless compared to stented aortic bio-prostheses. Recent meta-analyses, prospective randomized controlled trials and retrospective studies comparing the most frequently used stentless and stented aortic bio-prostheses were analyzed. In the present review, the types and implantation techniques of the bio-prosthesis that are seldom taken into account by most studies and reviews were integrated in the interpretation of the relevant reports. For stentless aortic root bio-prostheses, full-root vs. sub-coronary implantation offered better early transvalvular gradients, effective orifice area and left ventricular mass regression as well as late freedom from structural valve deterioration in retrospective studies. Early mortality and morbidity did not differ between the stentless and stented aortic bio-prostheses. Early transvalvular gradients, effective orifice area and regression of left ventricular hypertrophy were significantly better for stentless, especially as full-root, compared to stented bio-prostheses. The long-term valve-related survival for stentless aortic root and Toronto SPV bio-prosthesis was as good as that for stented pericardial aortic bio-prostheses. For full-root configuration this survival advantage was statistically significant. There seems to be not one but different ideal biological valve substitutes for different subgroups of patients. In patients with small aortic root or exposed to prosthesis-patient mismatch full-root implantation of stentless bio-prostheses may better meet functional needs of individual patients. Longer follow-ups on newer generation of stented bio-prostheses are needed for comparison of their hemodynamic performance with stentless counterparts especially in full-root configuration.

  17. A first experience with digital complete overdentures

    OpenAIRE

    Bajunaid, Salwa Omar

    2016-01-01

    The development of computer-aided design/computer-aided manufacturing systems for dentistry in the 1980s resulted in the successful fabrication of crowns, fixed dental prostheses, and superstructures for both natural teeth and dental implants. Today, this technology is available for constructing digitally designed and milled, completely removable dental prostheses. The procedure uses clinical and laboratory protocols that allow fabrication of completely removable prostheses within two clinica...

  18. Equally good fixation of cemented and uncemented cups in total trapeziometacarpal joint prostheses. A randomized clinical RSA study with 2-year follow-up.

    Science.gov (United States)

    Hansen, Torben Baek; Stilling, Maiken

    2013-02-01

    Cup failure is a recognized problem in total trapeziometacarpal (TM) joint prostheses; it may be related to poor fixation, which can be revealed by radiostereometric analysis (RSA). We compared the early implant migration of cemented trapezium cups to that of uncemented screw cups. In a prospective, parallel-group, randomized patient-blinded clinical trial, we included 32 hands in 28 patients (5 males) with a mean age of 58 (40-77) years and with Eaton stage-2 or -3 osteoarthritis of the trapeziometacarpal joint. Patients were randomized to surgery with a cemented DLC all-polyethylene cup (C) (n = 16) or an uncemented hydroxyapatite-coated chrome-cobalt Elektra screw cup (UC) (n = 16). Uncemented cups were inserted without threading of the bone. Stereoradiographs for evaluation of cup migration (primary effect size) and DASH and pain scores were obtained during 2 years of follow-up. The 2-year total translation (TT) was similar (p = 0.2): 0.24 mm (SD 0.10) for the C (n = 11) and 0.19 mm (SD 0.16) for the UC (n = 11). Variances were similar (p = 0.4). Judged by RSA, 2 UC cups and 1 C cup became loose (TT > 1 mm). Both UC cups were found to be loose at revision. Grip strength, pain, and DASH scores were similar between groups at all measurement points. Early implant fixation and clinical outcome were equally good with both cup designs. This is the first clinical RSA study on trapezium cups, and the method appears to be clinically useful for detection of loose implants.

  19. Influence of sodalite zeolite infiltration on the coefficient of thermal expansion and bond strength of all-ceramic dental prostheses.

    Science.gov (United States)

    Naji, Ghassan Abdul-Hamid; Omar, Ros Anita; Yahya, Rosiyah

    2017-03-01

    In all-ceramic systems, a high incidence of veneer chip-off has been reported in clinical studies. Coefficient of thermal expansion (CTE) behaviour is one of the factors that may increase residual stress in the interface and influence the veneer/core bond strength. Therefore, this study aimed to evaluate the effect of sodalite zeolite-infiltration on the CTE behaviour and bond strength of different all-ceramic prostheses. The case-study groups were synthesized sodalite zeolite-infiltrated alumina (IA-SOD) and synthesized sodalite zeolite-infiltrated zirconia-toughened alumina (ZTA) (IZ-SOD), while the control groups were glass-infiltrated alumina (IA-glass) and glass-infiltrated ZTA (IZ-glass). Forty cylindrical-shaped samples measuring 5 mm in diameter and 10 mm in height were tested for CTE using a thermo-mechanical analyser machine, and forty disc-shaped ceramic samples measuring 12 mm in diameter and 1.2 ± 0.2 mm in thickness were prepared using specially designed stainless steel split mould and veneered by cylinder-shaped (2 mm high × 2 mm diameter) low-fusing porcelain (Vita VM7). The veneer/core samples were sintered and tested for shear bond strength using a high precision universal testing machine. Scanning electron microscope, stereo microscope, atomic force microscope, and energy-dispersive X-ray spectroscopy were used to investigate the structural characteristics of samples at the fracture surface. The collected data were analyzed with a one-way ANOVA and Tukey HSD test (α=.05). IZ-SOD revealed highest CTE and shear bond strength values, while the IA-glass revealed the lowest values than the other groups. There was no significant difference in CTE and bond strength among IZ-SOD, IA-SOD and IZ-glass samples (p>0.05). The experimental SOD zeolite-infiltrated samples revealed higher CTE mismatch and bond strength along with a more favourable mode of failure than did the commercial glass-infiltrated samples. Sandblast technique is considered as effective

  20. Effect of number of pontics and impression technique on the accuracy of four-unit monolithic zirconia fixed dental prostheses.

    Science.gov (United States)

    Kim, Woong Ki; Kim, Sunjai

    2018-03-08

    Because of their relatively small scanning area, intraoral scanners may result in less accurate fixed dental prostheses (FDPs) than do laboratory scanners. The purpose of this in vitro study was to evaluate the accuracy of monolithic zirconia FDPs with different numbers of pontics fabricated with different impression techniques. The mandibular right premolars and molars of an acrylic resin model were prepared to receive 4-unit FDPs. Three master models were fabricated with epoxy resin: model NP, no pontic; model 1P, 1 pontic; and model 2P, 2 pontics. Each master model was scanned by using direct (DD) and indirect digitalization (ID). Four-unit monolithic zirconia FDPs were fabricated and divided into 3 groups (groups NP, 1P, and 2P) and then subdivided according to the digitalization technique (group DD and ID; n=10). The FDPs were also evaluated based on the presence (Po) or absence (NPo) of an adjacent pontic. The marginal, axial, and occlusal gap widths of each FDP were measured, and statistical analyses were performed to evaluate and compare the amount of gap present (α=.05). For direct digitalization, group 2P had significantly greater marginal (69.4 μm versus 60.9 μm or 62.3 μm; Pdigitalization. Direct digitalization resulted in significantly smaller gap widths in all measurement areas than indirect digitalization; however, the mean differences were less than 12 μm, which is considered clinically insignificant. The presence of an adjacent pontic had a significant effect on the adjacent marginal and axial gap widths. Copyright © 2017 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.

  1. Immediate occlusal loading of Osseotite implants in mandibular edentulous patients: a prospective observational report with 18-month data.

    Science.gov (United States)

    Drago, Carl J; Lazzara, Richard J

    2006-01-01

    To evaluate the efficacy of treatment consisting of placement and immediate occlusal loading of implants in 27 patients with edentulous mandibles. Twenty-seven patients were treated in two private practice settings. One hundred fifty-one implants were placed and immediately occlusally loaded with fixed implant prostheses (15 cement-retained, 12 screw-retained) on the day of implant placement. The implant-retained prostheses were inserted within 5 hours of implant placement. Patients were followed for at least 18 months. The required criteria for immediate occlusal loading was primary implant stability of at least 30 Ncm of insertion torque. The implant prostheses were removed at least 12 months post-placement and the implants were evaluated for primary clinical stability and radiographic bone apposition to implants. At the 12-month follow-up appointments, cumulative survival rates of 98.0% and 100% were recorded for implants and prostheses, respectively. Three implants failed within 3 months. All other implants were clinically successful. Immediate occlusal loading of multiple, splinted mandibular implants is an effective treatment when implants are stable at insertion and are rigidly splinted with implant-retained prostheses.

  2. Modified cementless total coxofemoral prosthesis: development, implantation and clinical evaluation

    Directory of Open Access Journals (Sweden)

    S.A. Arias

    2013-12-01

    Full Text Available The aim of this study was to modify canine coxofemoral prostheses and the clinical evaluation of the implantation. Fifteen canine hips and femora of cadavers were used in order to study the surface points of modification in prostheses and develop a perforation guide. Femoral stems and acetabular components were perforated and coated with biphasic calcium phosphate layer. Twelve young adult male mongrel dogs were implanted with coxofemoral prostheses. Six were operated upon and implanted with cemented canine modular hip prostheses, establishing the control group. The remaining six were implanted with a novel design of cementless porous tricalcic phosphate-hydroxyapatite coated hip prostheses. Clinical and orthopedic performance, complications, and thigh muscular hypotrophy were assessed up to the 120th post-operatory day. After 120 days, animals with cementless prostheses had similar clinical and orthopedic performance compared to the cemented group despite the increased pain thigh hypotrophy. Animals that underwent cementless hip prosthesis evidenced more pain, compared to animals with cemented hip prosthesis that required longer recuperation time. No luxations, two fractures and two isquiatic neurapraxies were identified in the course of the study. Using both the cemented and the bioactive coated cementless model were suitable to dogs, showing clinical satisfactory results. Osseointegration and biological fixation were observed in the animals with the modified cementless hip prosthesis.

  3. [Design and optimization of wireless power and data transmission for visual prosthesis].

    Science.gov (United States)

    Lei, Xuping; Wu, Kaijie; Zhao, Lei; Chai, Xinyu

    2013-11-01

    Boosting spatial resolution of visual prostheses is an effective method to improve implant subjects' visual perception. However, power consumption of visual implants greatly rises with the increasing number of implanted electrodes. In respond to this trend, visual prostheses need to develop high-efficiency wireless power transmission and high-speed data transmission. This paper presents a review of current research progress on wireless power and data transmission for visual prostheses, analyzes relative principles and requirement, and introduces design methods of power and data transmission.

  4. PERSENTASE PENGGUNA PROTESA DI INDONESIA

    Directory of Open Access Journals (Sweden)

    Magdarina Destri Agtini

    2012-09-01

    Full Text Available Teeth loss still becomes a major problem especially in developing countries. It can cause disfunction of mastication and Temporomandibular joint (TMJ. Furthermore, missing teeth can influence economic factor as well as physical and psychological aspect including aesthethic factor. Replacing of teeth loss with artificial denture is the only way to prevent those factors. A total sample 779.496 responden age 12 years and above were analysed using data of National Health Research (Riskesdas 2007. The objective of the study is to determine the index of missing teeth (M-T and the percentage of people using prostheses. The data is descriptively analysed using the Decayed (D-T, Missing (M-T, FilledfF-T, and Decayed Missing Filled Teeth (DMF-T, and data from Dentogram based on the result of permanent teeth examination; Missing Treatment Index (MTIand people using fixed and removable prostheses. The result of the study shows that M-T=3.9 out of DMF-T=4.8 and MTI=79.6%. Moreover, the percentage of people using prostheses is 4.5%. M-T, MTI, and people using prostheses increase in aged group of35 - 44 years old. M-T, MTI, and people using prostheses is higher in women compared to men. In addition, M-T and MTI are higher in rural area compared in urban area. However, the percentage of people using prostheses are higher in urban area than in rural area. According to the level of household expenditure per capita shows that MT and MTI are higher in group of people with low level of household expenditure. In contradictory, the percentage of people using prostheses is higher in those with high level of household expenditure.   Keywords: caries experience, DMF-T, Missing Teeth, Protesa

  5. CNC-milled titanium frameworks supported by implants in the edentulous jaw: a 10-year comparative clinical study.

    Science.gov (United States)

    Örtorp, Anders; Jemt, Torsten

    2012-03-01

    No long-term clinical studies covering more than 5 years are available on Computer Numeric Controlled (CNC) milled titanium frameworks. To evaluate and compare the clinical and radiographic performance of implant-supported prostheses provided with CNC titanium frameworks in the edentulous jaw with prostheses with cast gold-alloy frameworks during the first 10 years of function. Altogether, 126 edentulous patients were by random provided with 67 prostheses with titanium frameworks (test) in 23 maxillas and 44 mandibles, and with 62 prostheses with gold-alloy castings (control) in 31 maxillas and 31 mandibles. Clinical and radiographic 10-year data were collected for the groups and statistically compared on patient level. The 10-year prosthesis and implant cumulative survival rate was 95.6% compared with 98.3%, and 95.0% compared with 97.9% for test and control groups, respectively (p > .05). No implants were lost after 5 years of follow-up. Smokers lost more implants than nonsmokers after 5 years of follow-up (p .05), respectively. One prosthesis was lost in each group due to loss of implants, and one prosthesis failed due to framework fracture in the test group. Two metal fractures were registered in each group. More appointments of maintenance were needed for the prostheses in the maxilla compared with those in the mandible (p CNC-milled titanium frameworks are a viable alternative to gold-alloy castings for restoring patients with implant-supported prostheses in the edentulous jaw. © 2009 Wiley Periodicals, Inc.

  6. Appearance of low signal intensity lines in MRI of silicone breast implants.

    Science.gov (United States)

    Stroman, P W; Rolland, C; Dufour, M; Grondin, P; Guidoin, R G

    1996-05-01

    Magnetic resonance (MR) images of five explanted mammary prostheses were obtained with a 1.5 T GE Signa system using a conventional spin-echo pulse sequence, in order to investigate the low-intensity curvilinear lines which may be observed in MR images of silicone gel-filled breast implants under pressure from fibrous capsules. MR images showed ellipsoid prostheses, often containing multiple low-intensity curvilinear lines which in some cases presented an appearance very similar to that of the linguine sign. Upon opening the fibrous capsules, however, all of the prostheses were found to be completely intact demonstrating that the appearance of multiple low signal intensity curvilinear lines in MR images of silicone gel-filled prostheses is not necessarily a sign of prosthesis rupture. The MR image features which are specific to the linguine sign must be more precisely defined.

  7. Total replace in the knee with deformity in the valgus

    International Nuclear Information System (INIS)

    Lara Cortassio, Gilberto; Pineros Ramirez, Daniel Francisco

    2006-01-01

    The total knee arthroplasty with valgus deformity is a technically demanding surgery. The bone deformities and the soft tissues make difficult to balance the soft tissues, the mechanic axis restoration and the prostheses placement. We present the results of a retrospective study, observational, descriptive type series of cases of 40 patients (42 prostheses), operated on with valgus deformity of more than 10 grades, using the I. White side technique to balance the soft tissue, with and average following up of 4.5 years. Based on the knee society scale (KSS) we found satisfactory results in more than 92% of the cases (39 prostheses). The complications were: total lost of the knee extension in 2 patients and i femoropatellar misalignment. We recommend practicing a sequential liberation of the lateral soft tissue to obtain a good clinical result and prostheses longevity

  8. Ten-year survival and complication rates of lithium-disilicate (Empress 2) tooth-supported crowns, implant-supported crowns, and fixed dental prostheses.

    Science.gov (United States)

    Teichmann, Maren; Göckler, Fabian; Weber, Volker; Yildirim, Murat; Wolfart, Stefan; Edelhoff, Daniel

    2017-01-01

    To prospectively evaluate the clinical long-term outcome of tooth-supported crowns (SCs), implant-supported crowns (ISCs), and fixed dental prostheses (FDPs) made of a lithium-disilicate glass-ceramic framework material (IPS Empress 2). Between 1997 and 1999, a total of 184 restorations (106 SCs, 32 ISCs, 33 FDPs, and 13 diverse restorations) were placed in 73 patients. Kaplan-Meier estimation was applied for survival and chipping-free rates. Inter-group comparison of both rates was realized by a log rank test and a 2×2 contingency table. Also, SCs and FDPs were compared regarding adhesive vs. conventional cementation, and anterior vs. posterior positioning, for impact on survival. Due to 14 dropouts (34 restorations) and reasonable exclusion of 19 other restorations, the final dataset included: i) 87 SCs [37 patients, mean observation time 11.4 (±3.8)years]; ii) 17 ISCs [12 patients, mean observation time 13.3 (±2.3)years; and iii) 27 FDPs [19 patients, mean observation time 8.9 (±5.4)years]. The 10-year survival rate/chipping-free rate for SCs were 86.1%/83.4%, for ISCs 93.8%/94.1%, and for FDPs were 51.9%/90.8%. Both ISCs and SCs had a significantly higher survival than FDPs (ISCs vs. FDPs: both tests p=0.001; SCs vs. FDPs: p=0.001 and p=0.005). Differences in the chipping-free rates did not reach significance. Also, neither the cementation mode nor positioning of the restoration had an impact on survival. SCs had a slightly lower outcome than can generally be expected from single crowns. In contrast, ICSs had a favorable outcome and the FDPs predominantly failed. The practitioner's choice of dental materials is based (at best) on long-term experience. The present 10-year results are based on comprehensive data analyses and show the high potential of lithium-disilicate as a reliable material, especially for single-unit restoration. Copyright © 2016 Elsevier Ltd. All rights reserved.

  9. Voluntary Control of Residual Antagonistic Muscles in Transtibial Amputees: Feedforward Ballistic Contractions and Implications for Direct Neural Control of Powered Lower Limb Prostheses.

    Science.gov (United States)

    Huang, Stephanie; Huang, He

    2018-04-01

    Discrete, rapid (i.e., ballistic like) muscle activation patterns have been observed in ankle muscles (i.e., plantar flexors and dorsiflexors) of able-bodied individuals during voluntary posture control. This observation motivated us to investigate whether transtibial amputees are capable of generating such a ballistic-like activation pattern accurately using their residual ankle muscles in order to assess whether the volitional postural control of a powered ankle prosthesis using proportional myoelectric control via residual muscles could be feasible. In this paper, we asked ten transtibial amputees to generate ballistic-like activation patterns using their residual lateral gastrocnemius and residual tibialis anterior to control a computer cursor via proportional myoelectric control to hit targets positioned at 20% and 40% of maximum voluntary contraction of the corresponding residual muscle. During practice conditions, we asked amputees to hit a single target repeatedly. During testing conditions, we asked amputees to hit a random sequence of targets. We compared movement time to target and end-point accuracy. We also examined motor recruitment synchronization via time-frequency representations of residual muscle activation. The result showed that median end-point error ranged from -0.6% to 1% maximum voluntary contraction across subjects during practice, which was significantly lower compared to testing ( ). Average movement time for all amputees was 242 ms during practice and 272 ms during testing. Motor recruitment synchronization varied across subjects, and amputees with the highest synchronization achieved the fastest movement times. End-point accuracy was independent of movement time. Results suggest that it is feasible for transtibial amputees to generate ballistic control signals using their residual muscles. Future work on volitional control of powered power ankle prostheses might consider anticipatory postural control based on ballistic-like residual

  10. Eficiencia del método de polimerización con microondas en la rehabilitación por prótesis oculares individuales Effectiveness of microwaves polymerization method in individual ocular prostheses rehabilitation

    Directory of Open Access Journals (Sweden)

    Yamel Maqueira Rodríguez

    2011-06-01

    Full Text Available La polimerización con microondas es una nueva forma de llevar a cabo la confección de prótesis oculares individuales, sin embargo son aún insuficientes los estudios que exploren la eficiencia de este método. Se realizó una investigación para determinar el efecto de la polimerización con microondas en la eficiencia de la rehabilitación por prótesis oculares individuales. Se llevó a cabo un estudio de evaluación económica del tipo minimización de costos. Se comparó la polimerización tradicional simplificada con la polimerización por el método de microondas. Se consideraron para la efectividad el monómero residual, la deflexión transversal, la contracción lineal, la porosidad, la estabilidad del color, la resistencia al impacto, la dureza, la absorción de agua y la resistencia transversal. Se calcularon los costos médicos directos sobre la base de un modelo teórico para un paciente que requirió una prótesis ocular individual en el año 2006. Se documentó la igualdad de efectividad entre ambos métodos de polimerización. El costo teórico para un paciente que requirió una prótesis ocular individual fue de $ 79,85 USD y $ 70,07 USD por los métodos tradicionales y por microondas respectivamente. El método de polimerización con microondas ahorró en consumo de energía eléctrica y favoreció una mayor productividad de los recursos humanos, a la vez que incrementó la eficiencia.Microwaves polymerization is a new method to design individual ocular prostheses; however, there is a lack of studies exploring the effectiveness of present method to determine the effect of the microwaves polymerization in relation to effectiveness of individual ocular prostheses rehabilitation. An economic evaluation study was conducted to minimize costs. The simplified traditional polymerization was compared with microwaves polymerization method. For residual monomer the effectiveness transverse deflection, linear contraction, porosity, color

  11. REDUCED THROMBOGENICITY OF ARTIFICIAL MATERIALS BY COATING WITH ADPASE

    NARCIS (Netherlands)

    BAKKER, WW; VANDERLEI, B; NIEUWENHUIS, P; ROBINSON, P; Bartels, H.

    A novel coating solution for the improvement of biocompatibility of polyurethane-based vascular prostheses was tested in rabbits and rats in vivo. Segments of coated and uncoated vascular prostheses were implanted into the peritoneal cavity of rats, followed by induction of experimental haemorrhage;

  12. [In situ aortofemoral reconstructions in surgical treatment of infected aortofemoral grafts].

    Science.gov (United States)

    Badretdinov, I A; Pokrovsky, A V

    2015-01-01

    The article presents a review of literature sources covering possibilities of peiforming in situ aortofemoral reconstructions in surgical treatment of infected aortofemoral grafts. This methodology makes it possible to improve the outcomes of treatment for paraprosthetic infection at the expense of decreasing lethality and morbidity, increasing parameters of patency of grafts and lower limb salvage in the remote postoperative period. Mention should be made that in situ secondary aortofemoral reconstructions are fraught with danger of relapsing paraprosthetic infection, therefore many publications are dedicated to search for prostheses most resistant to infection. The article also presents the results of works devoted to the use of various types of prostheses for in situ secondary aortofemoral reconstructions: prostheses made of polytetrafluoroethylene (PTFE), synthetic grafts saturated with various antibacterial drugs and gelatine, cadaveric allografts, synthetic prostheses treated with silver ions, autovenous conduits based on the femoral and popliteal veins.

  13. Trends in Computer-Aided Manufacturing in Prosthodontics: A Review of the Available Streams

    Science.gov (United States)

    Bennamoun, Mohammed

    2014-01-01

    In prosthodontics, conventional methods of fabrication of oral and facial prostheses have been considered the gold standard for many years. The development of computer-aided manufacturing and the medical application of this industrial technology have provided an alternative way of fabricating oral and facial prostheses. This narrative review aims to evaluate the different streams of computer-aided manufacturing in prosthodontics. To date, there are two streams: the subtractive and the additive approaches. The differences reside in the processing protocols, materials used, and their respective accuracy. In general, there is a tendency for the subtractive method to provide more homogeneous objects with acceptable accuracy that may be more suitable for the production of intraoral prostheses where high occlusal forces are anticipated. Additive manufacturing methods have the ability to produce large workpieces with significant surface variation and competitive accuracy. Such advantages make them ideal for the fabrication of facial prostheses. PMID:24817888

  14. Trends in Computer-Aided Manufacturing in Prosthodontics: A Review of the Available Streams

    Directory of Open Access Journals (Sweden)

    Jaafar Abduo

    2014-01-01

    Full Text Available In prosthodontics, conventional methods of fabrication of oral and facial prostheses have been considered the gold standard for many years. The development of computer-aided manufacturing and the medical application of this industrial technology have provided an alternative way of fabricating oral and facial prostheses. This narrative review aims to evaluate the different streams of computer-aided manufacturing in prosthodontics. To date, there are two streams: the subtractive and the additive approaches. The differences reside in the processing protocols, materials used, and their respective accuracy. In general, there is a tendency for the subtractive method to provide more homogeneous objects with acceptable accuracy that may be more suitable for the production of intraoral prostheses where high occlusal forces are anticipated. Additive manufacturing methods have the ability to produce large workpieces with significant surface variation and competitive accuracy. Such advantages make them ideal for the fabrication of facial prostheses.

  15. Re-operation for aortic and mitral prosthetic dysfunctions.

    Science.gov (United States)

    Kaul, T K; Sastry, M R; Mercer, J L; Meade, J B

    1985-01-01

    The overall incidence of re-operation and prosthetic valve endocarditis was low in the present series as mechanical prostheses were used predominantly. The prosthetic dysfunctions were less frequent following the primary implantation with Bjork Shiley prostheses, but high operative risk was associated with the clotted Bjork Shiley prostheses. We also had unusual experience of strut fracture and sticking of Bjork Shiley discs in the closed position in both aortic and mitral positions. The early deaths were nil since the use of cardioplegic protection. Intra-operative bleeding due to adhesions can be minimised by using synthetic or heterologous pericardium during the primary operation.

  16. Intensity-Modulated Radiation Therapy with Noncoplanar Beams for Treatment of Prostate Cancer in Patients with Bilateral Hip Prosthesis-A Case Study

    International Nuclear Information System (INIS)

    Brooks, Chris; Cheung, Rex Min; Kudchadker, Rajat J.

    2010-01-01

    Megavoltage photon intensity-modulated radiation therapy (IMRT) is typically used in the treatment of prostate cancer at our institution. Approximately 1% to 2% of patients with prostate cancer have hip prostheses. The presence of the prosthesis usually complicates the planning process because of dose perturbation around the prosthesis, radiation attenuation through the prosthesis, and the introduction of computed tomography artifacts in the planning volume. In addition, hip prostheses are typically made of materials of high atomic number, which add uncertainty to the dosimetry of the prostate and critical organs in the planning volume. When the prosthesis is bilateral, treatment planning is further complicated because only a limited number of beam angles can be used to avoid the prostheses. In this case study, we will report the observed advantages of using noncoplanar beams in the delivery of IMRT to a prostate cancer patient with bilateral hip prostheses. The treatment was planned for 75.6 Gy using a 7-field coplanar approach and a noncoplanar arrangement, with all fields avoiding entrance though the prostheses. Our results indicate that, compared with the coplanar plan, the noncoplanar plan delivers the prescribed dose to the target with a slightly better conformality and sparing of rectal tissue versus the coplanar plan.

  17. Prototyping for surgical and prosthetic treatment.

    Science.gov (United States)

    Goiato, Marcelo Coelho; Santos, Murillo Rezende; Pesqueira, Aldiéris Alves; Moreno, Amália; dos Santos, Daniela Micheline; Haddad, Marcela Filié

    2011-05-01

    Techniques of rapid prototyping were introduced in the 1980s in the field of engineering for the fabrication of a solid model based on a computed file. After its introduction in the biomedical field, several applications were raised for the fabrication of models to ease surgical planning and simulation in implantology, neurosurgery, and orthopedics, as well as for the fabrication of maxillofacial prostheses. Hence, the literature has described the evolution of rapid prototyping technique in health care, which allowed easier technique, improved surgical results, and fabrication of maxillofacial prostheses. Accordingly, a literature review on MEDLINE (PubMed) database was conducted using the keywords rapid prototyping, surgical planning, and maxillofacial prostheses and based on articles published from 1981 to 2010. After reading the titles and abstracts of the articles, 50 studies were selected owing to their correlations with the aim of the current study. Several studies show that the prototypes have been used in different dental-medical areas such as maxillofacial and craniofacial surgery; implantology; neurosurgery; orthopedics; scaffolds of ceramic, polymeric, and metallic materials; and fabrication of personalized maxillofacial prostheses. Therefore, prototyping has been an indispensable tool in several studies and helpful for surgical planning and fabrication of prostheses and implants.

  18. Three-phase bone scan and indium white blood cell scintigraphy following porous coated hip arthroplasty: A prospective study of the prosthetic tip

    International Nuclear Information System (INIS)

    Oswald, S.G.; Van Nostrand, D.; Savory, C.G.; Callaghan, J.J.

    1989-01-01

    Although few reports address the use of three-phase bone scanning (TPBS) and 111 In-labeled white blood cell (In-WBC) scintigraphy in hip arthroplasty utilizing a porous coated prosthesis, the literature suggests that scintigraphic patterns in the uncomplicated patient may differ from that seen in the cemented prosthesis. In an attempt to determine the scintigraphic natural history, 25 uncomplicated porous coated hip arthroplasties in 21 patients were prospectively studied with serial TPBS and In-WBC at approximately 7 days, and at 3, 6, 12, 18, and 24 mo postoperatively. This report deals with findings related to the prosthetic tip. Only one of 136 flow studies were abnormal and only two of 136 blood-pool images demonstrated focally increased activity. All 25 prostheses (120 of 143 scans) demonstrated increased uptake on the bone phase images. The area about the tip was divided into three segments; increased uptake at 24 mo was noted in the medial, distal, and lateral segments in 16%, 72%, and 56% of prostheses, respectively. Twenty of 25 prostheses (82 of 142 scans) showed uptake on In-WBC scintigraphy, being noted in 48% of prostheses at 24 mo. We conclude that scintigraphic patterns in the uncomplicated patient with a porous coated prosthesis appear to differ from patterns described in cemented prostheses

  19. The mechanical design of a transfemoral prosthesis using computational tools and design methodology

    Directory of Open Access Journals (Sweden)

    John Sánchez Otero

    2012-09-01

    Full Text Available Artificial limb replacement with lower limb prostheses has been widely reported in current scientific literature. There are many lower limb prosthetic designs ranging from a single-axis knee mechanism to complex mechanisms involving microcontrollers, made from many materials ranging from lightweight, high specific strength ones (e.g., carbon fibre to traditional forms (e.g., stainless steel. However, the challenge is to design prostheses whose movement resembles the human body’s natural movement as closely as possible. Advances in prosthetics have enabled many amputees to return to their everyday activities; however, such prostheses are expensive, some costing as much as $60,000. Many of the affected population in Colombia have scarce economic resources; there is therefore a need to develop affordable functional prostheses.The Universidad del Norte’s Materials, Processes and Design Research Group and the Robotics and Intelligent Systems Group have been working on this line of research to develop modular prostheses which can be adjusted to each patient’s requirements. This research represents an initial methodological approach to developing a prosthesis in which software tools have been used (the finite element method with a criteria relationship matrix for selecting the best alternative while considering different aspects such as mod-ularity, cost, stiffness and weight.

  20. Immediate occluding definitive partial fixed prosthesis versus non-occluding provisional restorations - 4-month post-loading results from a pragmatic multicenter randomised controlled trial.

    Science.gov (United States)

    Heinemann, Friedhelm; Grufferty, Brendan; Papavasiliou, George; Dominiak, Marzena; García, Jaime Jiménez; Trullenque-Eriksson, Anna; Esposito, Marco

    2016-01-01

    To compare the clinical outcome of dental implants restored with definitive occluding partial fixed prostheses within 1 week, after implant placement with immediate non-occluding provisional restorations, which were to be replaced by definitive prostheses after 4 months. Fifty partially edentulous patients treated with one to three dental implants, at least 8.5 mm long and 4.0 mm wide inserted with a torque of at least 35 Ncm, were randomised in two groups of 25 patients each, to be immediately loaded with partial fixed prostheses. Patients of one group received one definitive screw-retained metal-ceramic prosthesis in occlusion within 1 week after placement. Patients of the other group received one non-occluding provisional acrylic reinforced prosthesis within 24 h after implant placement. Provisional prostheses were replaced after 4 months by definitive ones. The follow-up for all patients was 4-months post-loading. Outcome measures were prosthesis and implant failures, any complications, peri-implant marginal bone level changes, aesthetic evaluation by a clinician, patient satisfaction, chair time and number of visits at the dental office from implant placement to delivery of definitive restorations. No patient dropped out. Two immediately occlusally loaded implants with their related definitive prostheses (8%) failed early (difference in proportions = 0.08; 95% CI: -0.03 to 0.19; P = 0.490). Four complications occurred in the occlusal group versus one in the non-occlusal group; (difference in proportions = 0.12; 95% CI: -0.04 to 0.28; P = 0.349). Four months after loading, patients subjected to non-occlusal loading lost an average of 0.72 mm of peri-implant bone versus 0.99 mm of patients restored with occluding definitive partial fixed prostheses. There were no statistically significant differences for marginal bone level changes between the two groups (mean difference = -0.27 mm; 95% CI: -0.84 to 0.30; P = 0.349). The differences for aesthetic scores showed

  1. Influence of the provox Flush (R), blowing and imitated coughing on voice prosthetic biofilms in vitro

    NARCIS (Netherlands)

    Free, RH; Van Der Mei, HC; Elving, GJ; Van Weissenbruch, R; Albers, FWJ; Busscher, HJ

    Objective-This study investigates the effect of regular airflow, as an isolated single factor, through Groningen and Provox(R)2 voice prostheses on biofilm formation. Material and Methods-Groningen and Provox2 voice prostheses were placed in a modified Robbins device and inoculated with the total

  2. In vitro formation of oropharyngeal biofilms on silicone rubber treated with a palladium/tin salt mixture

    NARCIS (Netherlands)

    Dijk, F; Westerhof, M; Busscher, HJ; van Luyn, MJA; van der Mei, HC

    2000-01-01

    Adhesion of yeasts and bacteria to silicone rubber is one of the first steps in the biodeterioration of indwelling, silicone rubber voice prostheses. In this paper, silicone rubber, so-called "Groningen button," voice prostheses were treated with a colloidal palladium/tin solution to form a thin

  3. Reconstrucción de la articulación temporomandibular (ATM: prótesis aloplástica Reconstruction of the temporomandibular joint (TMJ: alloplastic prostheses

    Directory of Open Access Journals (Sweden)

    C. Goizueta Adame

    2005-02-01

    Full Text Available La incapacidad de desarrollar sistemas inertes eficaces para la sustitución completa de la articulación temporo-mandibular durante décadas ha generado una variedad de soluciones biológicas para un problema biomecánico. Los injertos autólogos no ofrecen garantías en funcionalidad, simetría, o estabilidad oclusal; resultan técnicamente más complejos y tienen mayor potencial morbilidad. El paciente candidato a reconstrucción completa de la ATM debe contar con la posibilidad de una prótesis si otras opciones fracasan. La reconstrucción aloplástica garantiza estabilidad oclusal, técnica sencilla y reproducible, estancia hospitalaria predecible y baja tasa de complicaciones con los sistemas protésicos actuales. Siempre van a existir pacientes en los que ésta sea la única opción, por lo tanto es primordial la medición de la magnitud de las fuerzas implicadas en la mecánica de la ATM para poder diseñar prótesis en base a modelos fiables como en otras articulaciones en las que ya han resuelto el problema.Incapabability to develop effective inert systems to total temporomandibular joint substitution during decades has genered several biologic solutions for a biomecanic question. Autologous grafts don´t offer security in functioning, simmetry, or oclusal estability; its have more coplex technique and more potencial morbility. Alloplastic reconstruction guarantees oclusal stability, single and reproducible technique, predictable time in hospital, and low morbility with actual prosthetic systems. Patients whos prostheses is only one option are going to exist always, so that it is primordial measures of magnitude of implicated strenghts in TMJ mecanic to can design prosthesis based on reliable models like others articulations which have just resolved the question.

  4. An Alternative Myoelectric Pattern Recognition Approach for the Control of Hand Prostheses: A Case Study of Use in Daily Life by a Dysmelia Subject

    Science.gov (United States)

    Ahlberg, Johan; Lendaro, Eva; Hermansson, Liselotte; Håkansson, Bo; Ortiz-Catalan, Max

    2018-01-01

    The functionality of upper limb prostheses can be improved by intuitive control strategies that use bioelectric signals measured at the stump level. One such strategy is the decoding of motor volition via myoelectric pattern recognition (MPR), which has shown promising results in controlled environments and more recently in clinical practice. Moreover, not much has been reported about daily life implementation and real-time accuracy of these decoding algorithms. This paper introduces an alternative approach in which MPR allows intuitive control of four different grips and open/close in a multifunctional prosthetic hand. We conducted a clinical proof-of-concept in activities of daily life by constructing a self-contained, MPR-controlled, transradial prosthetic system provided with a novel user interface meant to log errors during real-time operation. The system was used for five days by a unilateral dysmelia subject whose hand had never developed, and who nevertheless learned to generate patterns of myoelectric activity, reported as intuitive, for multi-functional prosthetic control. The subject was instructed to manually log errors when they occurred via the user interface mounted on the prosthesis. This allowed the collection of information about prosthesis usage and real-time classification accuracy. The assessment of capacity for myoelectric control test was used to compare the proposed approach to the conventional prosthetic control approach, direct control. Regarding the MPR approach, the subject reported a more intuitive control when selecting the different grips, but also a higher uncertainty during proportional continuous movements. This paper represents an alternative to the conventional use of MPR, and this alternative may be particularly suitable for a certain type of amputee patients. Moreover, it represents a further validation of MPR with dysmelia cases. PMID:29637030

  5. Tibial rotation kinematics subsequent to knee arthroplasty

    Science.gov (United States)

    Collins, Duane J.; Khatib, Yasser H.; Parker, David A.; Jenkin, Deanne E.; Molnar, Robert B.

    2015-01-01

    Background The use of computer assisted joint replacement has facilitated precise intraoperative measurement of knee kinematics. The changes in “screw home mechanism” (SHM) resulting from Total Knee Arthroplasty (TKA) with different prostheses and constraints has not yet been accurately described. Methods A pilot study was first completed. Intraoperative kinematic data was collected two groups of 15 patients receiving different prostheses. Results On average, patients lost 5.3° of ER (SD = 6.1°). There was no significant difference between the prostheses or different prosthetic constraints. Conclusions There significant loss of SHM after TKA. Further research is required to understand its impact on patient function. PMID:25829754

  6. THE USE OF 3D SCANNING AND RAPID PROTOTYPING IN MEDICAL ENGINEERING

    Directory of Open Access Journals (Sweden)

    Octavian CIOBANU

    2013-05-01

    Full Text Available New cost effective scanning and modeling techniques are used today to process data acquisition and3D reconstruction in order to fabricate prostheses and orthoses by 3D printing. Paper approaches two scanningand 3D modeling techniques used in order to fabricate orthoses and prostheses. In this study, an artificialprosthetic ear was produced through 3D printing using two scanning techniques: structured light scanningtechnique and single camera stereo photogrammetric scanning technique. The processing phases are describedand discussed from data acquisition to 3D printing. The surface scanning and 3D reconstruction techniques willcontinue to increase the accessibility of prostheses and orthoses, making them more cost-effective and morecomfortable.

  7. Internal fit of three-unit fixed dental prostheses produced by computer-aided design/computer-aided manufacturing and the lost-wax metal casting technique assessed using the triple-scan protocol.

    Science.gov (United States)

    Dahl, Bjørn E; Dahl, Jon E; Rønold, Hans J

    2018-02-01

    Suboptimal adaptation of fixed dental prostheses (FDPs) can lead to technical and biological complications. It is unclear if the computer-aided design/computer-aided manufacturing (CAD/CAM) technique improves adaptation of FDPs compared with FDPs made using the lost-wax and metal casting technique. Three-unit FDPs were manufactured by CAD/CAM based on digital impression of a typodont model. The FDPs were made from one of five materials: pre-sintered zirconium dioxide; hot isostatic pressed zirconium dioxide; lithium disilicate glass-ceramic; milled cobalt-chromium; and laser-sintered cobalt-chromium. The FDPs made using the lost-wax and metal casting technique were used as reference. The fit of the FDPs was analysed using the triple-scan method. The fit was evaluated for both single abutments and three-unit FDPs. The average cement space varied between 50 μm and 300 μm. Insignificant differences in internal fit were observed between the CAD/CAM-manufactured FDPs, and none of the FPDs had cement spaces that were statistically significantly different from those of the reference FDP. For all FDPs, the cement space at a marginal band 0.5-1.0 mm from the preparation margin was less than 100 μm. The milled cobalt-chromium FDP had the closest fit. The cement space of FDPs produced using the CAD/CAM technique was similar to that of FDPs produced using the conventional lost-wax and metal casting technique. © 2017 Eur J Oral Sci.

  8. Effect of prosthesis endplate lordosis angles on L5-S1 kinematics after disc arthroplasty.

    Science.gov (United States)

    Tsitsopoulos, Parmenion P; Wojewnik, Bartosz; Voronov, Leonard I; Havey, Robert M; Renner, Susan M; Zelenakova, Julia; McIntosh, Braden; Carandang, Gerard; Abjornson, Celeste; Patwardhan, Avinash G

    2012-06-01

    We hypothesized that L5-S1 kinematics will not be affected by the lordosis distribution between the prosthesis endplates. Twelve cadaveric lumbosacral spines (51.3 ± 9.8 years) were implanted with 6° or 11° prostheses (ProDisc-L) with four combinations of superior/inferior lordosis (6°/0°, 3°/3°, 11°/0°, 3°/8°). Specimens were tested intact and after prostheses implantation with different lordosis distributions. Center of rotation (COR) and range of motion (ROM) were quantified. Six-degree lordosis prostheses (n = 7) showed no difference in flexion-extension ROM, regardless of design (6°/0° or 3°/3°) (p > 0.05). In lateral bending (LB), both designs reduced ROM (p lordosis prostheses (n = 5) showed no difference in flexion-extension ROM for either design (p > 0.05). LB ROM decreased with distributed lordosis prostheses (3°/8°) (p lordosis distribution among the two prosthesis endplates. The ProDisc-L prosthesis design where all lordosis is concentrated in the superior endplate yielded COR locations that were anterior and caudal to intact controls. The prosthesis with lordosis distributed between the two endplates yielded a COR that tended to be closer to intact. Further clinical and biomechanical studies are needed to assess the long-term impact of lordosis angle distribution on the fate of the facet joints.

  9. Current topics in the radiology of joint replacement surgery

    International Nuclear Information System (INIS)

    Weissman, B.N.

    1990-01-01

    Several methods of total hip joint replacement are currently used. Radiographic appearances after cemented, bone ingrowth, press-fit, and bipolar hip prostheses are reviewed. The roles of nuclear medicine and arthrographic procedures for identifying complications are discussed. Total knee prostheses and, in particular, complications related to the patellar component are described.115 references

  10. Comparison of marginal and internal fit of 3-unit ceramic fixed dental prostheses made with either a conventional or digital impression.

    Science.gov (United States)

    Su, Ting-Shu; Sun, Jian

    2016-09-01

    For 20 years, the intraoral digital impression technique has been applied to the fabrication of computer aided design and computer aided manufacturing (CAD-CAM) fixed dental prostheses (FDPs). Clinical fit is one of the main determinants of the success of an FDP. Studies of the clinical fit of 3-unit ceramic FDPs made by means of a conventional impression versus a digital impression technology are limited. The purpose of this in vitro study was to evaluate and compare the internal fit and marginal fit of CAD-CAM, 3-unit ceramic FDP frameworks fabricated from an intraoral digital impression and a conventional impression. A standard model was designed for a prepared maxillary left canine and second premolar and missing first premolar. The model was scanned with an intraoral digital scanner, exporting stereolithography (STL) files as the experimental group (digital group). The model was used to fabricate 10 stone casts that were scanned with an extraoral scanner, exporting STL files to a computer connected to the scanner as the control group (conventional group). The STL files were used to produce zirconia FDP frameworks with CAD-CAM. These frameworks were seated on the standard model and evaluated for marginal and internal fit. Each framework was segmented into 4 sections per abutment teeth, resulting in 8 sections per framework, and was observed using optical microscopy with ×50 magnification. Four measurement points were selected on each section as marginal discrepancy (P1), mid-axial wall (P2), axio-occusal edge (P3), and central-occlusal point (P4). Mean marginal fit values of the digital group (64 ±16 μm) were significantly smaller than those of the conventional group (76 ±18 μm) (Pdigital group (111 ±34 μm) were significantly smaller than those of the conventional group (132 ±44 μm) (Pdigital and conventional impressions showed clinically acceptable marginal and internal fit. The marginal and internal fit of frameworks fabricated from the intraoral

  11. SU-F-J-161: Prostate Contouring in Patients with Bilateral Hip Prostheses: Impact of Using Artifact-Reduced CT Images and MRI

    Energy Technology Data Exchange (ETDEWEB)

    Elzibak, A; Loblaw, A; Morton, G; Vesprini, D; Liu, S; Chung, H; Davidson, M [Odette Cancer Centre, Sunnybrook Health Sciences Centre, Toronto, Ontario (Canada)

    2016-06-15

    Purpose: To investigate the usefulness of metal artifact reduction in CT images of patients with bilateral hip prostheses (BHP) for contouring the prostate and determine if the inclusion of MR images provides additional benefits. Methods: Five patients with BHP were CT scanned using our clinical protocol (140kV, 300mAs, 3mm slices, 1.5mm increment, Philips Medical Systems, OH). Images were reconstructed with the orthopaedic metal artifact reduction (O-MAR) algorithm. MRI scanning was then performed (1.5T, GE Healthcare, WI) with a flat table-top (T{sub 2}-weighted, inherent body coil, FRFSE, 3mm slices with 0mm gap). All images were transferred to Pinnacle (Version 9.2, Philips Medical Systems). For each patient, two data sets were produced: one containing the O-MAR-corrected CT images and another containing fused MRI and O-MAR-corrected CT images. Four genito-urinary radiation oncologists contoured the prostate of each patient on the O-MAR-corrected CT data. Two weeks later, they contoured the prostate on the fused data set, blinded to all other contours. During each contouring session, the oncologists reported their confidence in the contours (1=very confident, 3=not confident) and the contouring difficulty that they experienced (1=really easy, 4=very challenging). Prostate volumes were computed from the contours and the conformity index was used to evaluate inter-observer variability. Results: Larger prostate volumes were found on the O-MAR-corrected CT set than on the fused set (p< 0.05, median=36.9cm{sup 3} vs. 26.63 cm{sup 3}). No significant differences were noted in the inter-observer variability between the two data sets (p=0.3). Contouring difficulty decreased with the addition of MRI (p<0.05) while the radiation oncologists reported more confidence in their contours when MRI was fused with the O-MAR-corrected CT data (p<0.05). Conclusion: This preliminary work demonstrated that, while O-MAR correction to CT images improves visualization of anatomy, the

  12. Implant and prosthodontic survival rates with implant fixed complete dental prostheses in the edentulous mandible after at least 5 years: a systematic review.

    Science.gov (United States)

    Papaspyridakos, Panos; Mokti, Muizzaddin; Chen, Chun-Jung; Benic, Goran I; Gallucci, German O; Chronopoulos, Vasilios

    2014-10-01

    The treatment of mandibular edentulism with implant fixed complete dental prostheses (IFCDPs) is a routinely used treatment option. The study aims to report the implant and prosthodontic survival rates associated with IFCDPs for the edentulous mandible after an observation period of a minimum 5 years. An electronic MEDLINE/PubMED search was conducted to identify randomized controlled clinical trials and prospective studies with IFCDPs for the edentulous mandible. Clinical studies with at least 5-year follow-up were selected. Pooled data were statistically analyzed and cumulative implant- and prosthesis survival rates were calculated by meta-analysis, regression, and chi-square statistics. Implant-related and prosthesis-related factors were identified and their impact on survival rates was assessed. Seventeen prospective studies, including 501 patients and 2,827 implants, were selected for meta-analysis. The majority of the implants (88.5% of all placed implants) had been placed in the interforaminal area. Cumulative implant survival rates for rough surface ranged from 98.42% (95% confidence interval [CI]: 97.98-98.86) (5 years) to 96.86% (95% CI: 96.00-97.73) (10 years); smooth surface implant survival rates ranged from 98.93% (95% CI: 98.38-99.49) (5 years) to 97.88% (95% CI: 96.78-98.98) (10 years). The prosthodontic survival rates for 1-piece IFCDPs ranged from 98.61% (95% CI: 97.80-99.43) (5 years) to 97.25% (95% CI: 95.66-98.86) (10 years). Treatment with mandibular IFCDPs yields high implant and prosthodontic survival rates (more than 96% after 10 years). Rough surface implants exhibited cumulative survival rates similar to the smooth surface ones (p > .05) in the edentulous mandible. The number of supporting implants and the antero-posterior implant distribution had no influence (p > .05) on the implant survival rate. The prosthetic design and veneering material, the retention type, and the loading protocol (delayed, early, and immediate) had no

  13. Advances in implantable bionic devices for blindness: a review.

    Science.gov (United States)

    Lewis, Philip M; Ayton, Lauren N; Guymer, Robyn H; Lowery, Arthur J; Blamey, Peter J; Allen, Penelope J; Luu, Chi D; Rosenfeld, Jeffrey V

    2016-09-01

    Since the 1950s, vision researchers have been working towards the ambitious goal of restoring a functional level of vision to the blind via electrical stimulation of the visual pathways. Groups based in Australia, USA, Germany, France and Japan report progress in the translation of retinal visual prosthetics from the experimental to clinical domains, with two retinal visual prostheses having recently received regulatory approval for clinical use. Regulatory approval for cortical visual prostheses is yet to be obtained; however, several groups report plans to conduct clinical trials in the near future, building upon the seminal clinical studies of Brindley and Dobelle. In this review, we discuss the general principles of visual prostheses employing electrical stimulation of the visual pathways, focusing on the retina and visual cortex as the two most extensively studied stimulation sites. We also discuss the surgical and functional outcomes reported to date for retinal and cortical prostheses, concluding with a brief discussion of novel developments in this field and an outlook for the future. © 2016 Royal Australasian College of Surgeons.

  14. Material selection for prosthetics of defects of dentitions at patients with functional and inflammatory bowel diseases

    Directory of Open Access Journals (Sweden)

    Myalina Yu.N.

    2012-06-01

    Full Text Available Objective: To study clinical-morphological characteristics of parodontal diseases, markers of density of bone tissue and to define rational approaches to prosthetics of defects of dentitions in patients with colon diseases. Materials and methods: 55 patients with ulcerative colitis, even 80 with the syndrome of the irritable bowel syndrome with defects of dentitions, have been applied metallic, cement prostheses and having prostheses on the intraosseous of implants. Markers of bone metabolism in the blood serum and in the oral liquid, the proliferating activity of the epitheliocytes of periodontium have been evaluated according to the morphometric indices of the markers of the proliferation of ki-67, cyclein D1, the inhibitor of apoptosis of bcl-2 have been inspected. Results: Connection of intensity of periodontitis with the stage of colon disease has been stated. Metallic dental prostheses have been served as additional risk factors of development of parodontal diseases in patients with ulcerative colitis. Conclusion: The diagnostic value of the markers of proliferation has been determined in diagnostics of parodontal disease during the application of prostheses from different materials.

  15. Reconstituição da valva pulmonar e via de saída do ventrículo direito, com prótese bivalvular e prótese tubular valvada de tronco pulmonar de porco: estudo experimental e aplicação clínica Pulmonary valve and right ventricular oulet tract reconstruction with biovalvular prostheses and valved tubular prostheses of the pig pulmonary artery: experimental study and clinical application

    Directory of Open Access Journals (Sweden)

    Miguel A Maluf

    1993-03-01

    aplicação clínica da prótese bivalvular foi realizada em 3 pacientes portadores de t. de Fallot associada a hipoplasía do anel pulmonar (2 casos e agenesia da valva pulmonar (1 caso, com idades de 16, 2 e 7 anos. Após evolução de 3 a 10 meses, os gradientes variaram entre 10 mmHg e 20 mmHg e discreta insuficiência pulmonar valvar ao estudo ecodopplercardiográfico. A prótese tubular valvar foi implantada em 2 pacientes portadores de atresia pulmonar associada a comunicação interventricular (CIV e outro a transposição corrigida das grandes artérias (TCGA associada a GIV e estenose subpulmonar, com idades de 10 e 6 anos, respectivamente. Após evolução de 5 a 12 meses, foram detectados suficiência da valva pulmonar, gradientes entre 15 mmHg e 18 mmHg, sem sinais de calcificação. Apesar de se considerar aceitáveis os resultados desta experiência, a ampliação das indicações deverá ser feita com cautela, até o melhor conhecimento da resistência da prótese a calcificação, infecção, obstrução e rotura.Obstruction of the right ventricle outlet tract (RVOT has been the object of arguments regarding its surgical correction, while there are different criteria for reconstruction. Thus two kinds of prostheses were developed from the pig pulmonary trunk (PT. 1 One with two valves of the pulmonary valve (PV, named bivalvular graft, and could be used for correction of Fallot with pulmonary ring hypoplasia. 2 The other, with a tubular form, containing the pig PV itself and named valved conduit, could be used in RVOT reconstruction for patients with pulmonary atresia (PA. These prostheses were tested in an experimental model: implant of the bivalvular graft was performed in 16 sheep with the aid of extracorporeal circulation (ECC. The surgical technique consisted of resection of the two valves of the PV and of the anterior wall of the infundibulum; this condition was similar to Fallot correction. Implant of the valvular conduit was carried out in 12

  16. A first experience with digital complete overdentures

    Directory of Open Access Journals (Sweden)

    Salwa Omar Bajunaid

    2016-07-01

    Full Text Available The development of computer-aided design/computer-aided manufacturing systems for dentistry in the 1980s resulted in the successful fabrication of crowns, fixed dental prostheses, and superstructures for both natural teeth and dental implants. Today, this technology is available for constructing digitally designed and milled, completely removable dental prostheses. The procedure uses clinical and laboratory protocols that allow fabrication of completely removable prostheses within two clinical appointments. The aim of this clinical report is to present the author’s first experience with digital complete overdentures, the practicality of this technology, and patient feedback. Compared with conventional overdentures, the fit of the digital prostheses was improved because the cameo and flanges of the prostheses were nicely shaped and rolled, and this enhanced their stability and retention. Occlusion was also excellent. However, aesthetics in terms of the alignment, shape, and size of the maxillary overdenture teeth were inacceptable. Despite some of the drawbacks identified in our study, the use of removable digital dentures does provide excellent adaptation of the denture base and requires fewer clinic visits. We anticipate that the unsatisfactory aesthetic outcomes presented in this report can be corrected with more experience. We also believe that acquiring an in-house scanning machine would be beneficial. We highly recommend including this technique in dental school curriculums at both the undergraduate and graduate levels in order to keep students and residents up to date on the latest technology available.

  17. Clinical experiences with laser-welded titanium frameworks supported by implants in the edentulous mandible: a 5-year follow-up study.

    Science.gov (United States)

    Ortorp, A; Linden, B; Jemt, T

    1999-01-01

    The purpose of this study was to report the 5-year clinical performance of implant-supported prostheses with laser-welded titanium frameworks and to compare their performance with that of prostheses provided with conventional cast frameworks. On a routine basis, a consecutive group of 824 edentulous patients were provided with fixed prostheses supported by implants in the edentulous mandible. In addition to conventional gold-alloy castings, patients were at random provided with 2 kinds of laser-welded titanium frameworks. In all, 155 patients were included in the 2 titanium framework groups. A control group of 53 randomly selected patients with conventional gold-alloy castings was used for comparison. Clinical and radiographic 5-year data was collected for the 3 groups. All followed patients still had fixed prostheses in the mandible after 5 years. The overall cumulative success rates were 95.9% and 99.7% for titanium-framework prostheses and implants, respectively. The corresponding success rates for the control group were 100% and 99.6%, respectively. Bone loss was 0.5 mm on average during the 5-year follow-up period. The most common complications for titanium frameworks were resin or tooth fractures, gingival inflammation, and fractures of the metal frames (10%). One of the cast frameworks fractured and was resoldered. Loose and fractured implant screw components were few (laser-welded titanium frameworks seem to be a viable alternative to conventional castings in the edentulous mandible.

  18. Revision washout decreases implant capsule tissue culture positivity: a multicenter study.

    Science.gov (United States)

    Henry, Gerard D; Carson, Culley C; Wilson, Steven K; Wiygul, Jeremy; Tornehl, Chris; Cleves, Mario A; Simmons, Caroline J; Donatucci, Craig F

    2008-01-01

    Positive cultures, visible biofilm and confocal micrography confirm bacterial presence on clinically uninfected inflatable penile prostheses at revision surgery. Salvage irrigation has been proved to rescue patients with clinically infected inflatable penile prostheses. Similar washout at revision for noninfectious reasons significantly lowers subsequent infection rates. We investigated a larger series of patients for positive culture rates and evaluated implant capsule tissue culture rates before and after revision washout. At 4 institutions a total of 148 patients with inflatable penile prostheses underwent revision surgery for noninfectious reasons between June 2001 and September 2005. Swab cultures of the fluid around the pump and visible biofilm were obtained. Also, in 65 patients a wedge of tissue from the capsule that forms around the pump was cultured. After implant removal revision washout of the implant spaces was performed and a second wedge of tissue was cultured. Of the 148 patients 97 (66%) had positive bacterial swab cultures of the fluid around the pump or biofilm. A total of 124 isolates were cultured. Of the 65 implant capsule tissue cultures obtained before washout 28 (43%) were positive for bacteria, while 16 (25%) obtained after revision washout were positive. Positive cultures and visible bacterial biofilm are present on clinically uninfected inflatable penile prostheses at revision surgery in most patients. Revision washout appears to decrease the bacterial load on implant capsule tissue at revision surgery of inflatable penile prostheses for noninfectious reasons.

  19. A first experience with digital complete overdentures.

    Science.gov (United States)

    Bajunaid, Salwa Omar

    2016-07-01

    The development of computer-aided design/computer-aided manufacturing systems for dentistry in the 1980s resulted in the successful fabrication of crowns, fixed dental prostheses, and superstructures for both natural teeth and dental implants. Today, this technology is available for constructing digitally designed and milled, completely removable dental prostheses. The procedure uses clinical and laboratory protocols that allow fabrication of completely removable prostheses within two clinical appointments. The aim of this clinical report is to present the author's first experience with digital complete overdentures, the practicality of this technology, and patient feedback. Compared with conventional overdentures, the fit of the digital prostheses was improved because the cameo and flanges of the prostheses were nicely shaped and rolled, and this enhanced their stability and retention. Occlusion was also excellent. However, aesthetics in terms of the alignment, shape, and size of the maxillary overdenture teeth were inacceptable. Despite some of the drawbacks identified in our study, the use of removable digital dentures does provide excellent adaptation of the denture base and requires fewer clinic visits. We anticipate that the unsatisfactory aesthetic outcomes presented in this report can be corrected with more experience. We also believe that acquiring an in-house scanning machine would be beneficial. We highly recommend including this technique in dental school curriculums at both the undergraduate and graduate levels in order to keep students and residents up to date on the latest technology available.

  20. Bone-anchored titanium implants for auricular rehabilitation: case report and review of literature.

    Science.gov (United States)

    Gumieiro, Emne Hammoud; Dib, Luciano Lauria; Jahn, Ricardo Schmitutz; Santos Junior, João Ferreira dos; Nannmark, Ulf; Granström, Gösta; Abrahão, Márcio

    2009-01-01

    Osseointegrated implants have acquired an important role in the prosthetic rehabilitation of patients with craniofacial defects. The main indications are lack of local tissue for autogenous reconstruction, previous reconstruction failure and selection of this technique by the patient. This paper presents a clinical case and discusses indications and advantages of the osseointegrated implant technique for retention of auricular prostheses. Case report, Universidade Federal de São Paulo (UNIFESP). A female patient received three auricular implants after surgical resection of a hemangioma in her left ear. The time taken for osseointegration of the temporal bone was three months. After fabrication of the implant-retained auricular prosthesis, the patient was monitored for 12 months. The clinical parameters evaluated showed good postoperative healing, healthy peri-implant tissue, good hygiene and no loss of implants. Good hygiene combined with thin and immobile peri-implant soft tissues resulted in minimal complications. Craniofacial implant integration appears to be site-dependent; increasing age affects osseointegration in the temporal bone. The frequency of adverse skin reactions in peri-implant tissues is generally low. The surgical technique for rehabilitation using implant-retained auricular prostheses seems to be simple. It is associated with low rates of adverse skin reactions and long-term complications. Prostheses anchored by osseointegrated implants seem to provide better retention than do prostheses supported on spectacle frames, less risk of discoloration through the use of adhesives and better esthetic results than do prostheses anchored in the surgical cavity.

  1. Impact of Removable Partial Dental Prostheses on the Oral Health-Related Quality of Life of a South African Cohort with Varied Distributions of Missing Posterior Teeth.

    Science.gov (United States)

    Khan, Sadika; Chikte, Usuf; Omar, Ridwaan

    2017-10-25

    To determine the impact of removable partial dental prostheses on satisfying the daily functioning and quality of life (QoL) of adult patients with different distributions of missing posterior teeth. A cross-sectional interventional study was carried out on 80 patients having variously distributed posteriorly shortened and interrupted arches. Treatment comprised provision of partial dentures by senior dental students, supervised by senior clinical teachers who had knowledge of the potential benefits of the shortened dental arch (SDA) concept. The Oral Impacts on Daily Performance Index was completed before and 6 months after prosthetic treatment across groups comprising Kennedy Classes I, II, and III arches. Analysis included descriptive statistics and associations and comparisons between variables. Mean age of patients was 57.4 years (SD = 13.1), many were retired (72.2%), and a majority were females (60%). Most patients lived in urban areas (95%), and were largely unemployed (63.3%). At pretreatment, only 31.3% of patients reported having good dental health and satisfaction with their current oral state, while 82.5% said they had a great need for treatment. The negative oral impacts that were most frequently experienced were those of eating (67.5%), smiling (50%), and being emotionally disturbed (63.8%). Post-treatment, 76.3% indicated good oral health and satisfaction with no significant differences between the 3 Kennedy groups. Any further negative impacts were reported mostly for Kennedy Classes I and II. Overall, significant reductions of negative impacts were observed following treatment with dentures, across the 3 Kennedy groups, with respect to improved function, satisfaction, and oral health-related QoL. The findings confirm the reliance by partially dentate patients in all 3 Kennedy groups on dentures for improved oral health, although the possible benefits of the SDA concept as an alternative treatment option was not specifically explored. © 2017 by

  2. Diverse modalities of gingival replacement: A report of three cases

    Directory of Open Access Journals (Sweden)

    Dileep N Vinnakota

    2012-01-01

    Full Text Available Gingival replacement is often a component of comprehensive prosthodontics. Gingival prostheses may be fixed or removable. It can be made from acrylics, composite resins, silicones or porcelain-based materials.This paper describes different clinical situations in which three types of gingival prostheses, removable acrylic veneer with melanin pigmentation, fixed ceramic veneer and flexible nylon based veneer, were used effectively.

  3. Porps, torps, and homografts in tympanoplasty.

    Science.gov (United States)

    Gillanders, D A; Cambon, K G; Doyle, P J

    1980-04-01

    A brief review of the use of plastique prostheses in ossiculoplasty, as well as the use of homograft tympanic membranes along with our experience is reported. Plastipore prostheses have been found to be useful, and their continued use is advocated. Homograft tympanic membranes are useful in repairing those ears which have undergone extensive damage to the tympanic membrane and ossicles.

  4. Three-unit posterior zirconia-ceramic fixed dental prostheses (FDPs) veneered with layered and milled (CAD-on) veneering ceramics: 1-year follow-up of a randomized controlled clinical trial.

    Science.gov (United States)

    Grohmann, Philipp; Bindl, Andreas; Hämmerle, Christoph; Mehl, Albert; Sailer, Irena

    2015-01-01

    The aim of this multicenter randomized controlled clinical trial was to test posterior zirconia-ceramic fixed dental prostheses (FDPs) veneered with a computer-aided design/computer- assisted manufacture (CAD/CAM) lithium disilicate veneering ceramic (CAD-on) and manually layered zirconia veneering ceramic with respect to survival of the FDPs, and technical and biologic outcomes. Sixty patients in need of one posterior three-unit FDP were included. The zirconia frameworks were produced with a CAD/CAM system (Cerec inLab 3D/Cerec inEOS inLab). Thirty FDPs were veneered with a CAD/CAM lithium disilicate veneering ceramic (Cad-on) (test) and 30 were veneered with a layered zirconia veneering ceramic (control). For the clinical evaluation at baseline, 6, and 12 months, the United States Public Health Service (USPHS) criteria were used. The biologic outcome was judged by comparing the plaque control record (PCR), bleeding on probing (BOP), and probing pocket depth (PPD). Data were statistically analyzed. Fifty-six patients were examined at a mean follow-up of 13.9 months. At the 1-year follow-up the survival rate was 100% in the test and in the control group. No significant differences of the technical outcomes occurred. Major chipping occurred in the control group (n = 3) and predominantly minor chipping in the test group (minor n = 2, major n = 1). No biologic problems or differences were found. Both types of zirconia-ceramic FDPs exhibited very good clinical outcomes without differences between groups. Chipping occurred in both types of FDPs at small amounts, yet the extension of the chippings differed. The test FDPs predominantly exhibited minor chipping, the control FDPs major chipping.

  5. Effects of prosthesis use on the capability to control myoelectric robotic prosthetic hands.

    Science.gov (United States)

    Atzori, Manfredo; Hager, Anne-Gabrielle Mittaz; Elsig, Simone; Giatsidis, Giorgio; Bassetto, Franco; Muller, Henning

    2015-08-01

    The natural control of robotic prosthetic hands with non-invasive techniques is still a challenge: myoelectric prostheses currently give some control capabilities; the application of pattern recognition techniques is promising and recently started to be applied in practice but still many questions are open in the field. In particular, the effects of clinical factors on movement classification accuracy and the capability to control myoelectric prosthetic hands are analyzed in very few studies. The effect of regularly using prostheses on movement classification accuracy has been previously studied, showing differences between users of myoelectric and cosmetic prostheses. In this paper we compare users of myoelectric and body-powered prostheses and intact subjects. 36 machine-learning methods are applied on 6 amputees and 40 intact subjects performing 40 movements. Then, statistical analyses are performed in order to highlight significant differences between the groups of subjects. The statistical analyses do not show significant differences between the two groups of amputees, while significant differences are obtained between amputees and intact subjects. These results constitute new information in the field and suggest new interpretations to previous hypotheses, thus adding precious information towards natural control of robotic prosthetic hands.

  6. Powered Lower Limb Prostheses

    OpenAIRE

    Grimmer, Martin

    2015-01-01

    Human upright locomotion emerged about 6 million years ago. It is achieved by a complex interaction of the biological infrastructure and the neural control. Bones, muscles, tendons, central nervous commands and reflex mechanisms interact to provide robust and efficient bipedal movement patterns like walking or running. Next to these locomotion tasks humans can also perform complex movements like climbing, dancing or jumping. Diseases or traumatic events may cause the loss of parts of the biol...

  7. Awareness, attitudes, need and demand on replacement of missing teeth among a group of partially dentate patients attending a University Dental Hospital.

    Science.gov (United States)

    Jayasinghe, Rasika Manori; Perera, Janana; Jayasinghe, Vajira; Thilakumara, Indika P; Rasnayaka, Sumudu; Shiraz, Muhammad Hanafi Muhammad; Ranabahu, Indra; Kularatna, Sanjeewa

    2017-07-27

    Our objective was to assess awareness, attitudes, need and demand on replacement of missing teeth according to edentulous space, age, gender, ethnicity, educational level and socio-economical status of the patient. 76.2% of the study group was opined that the missing teeth should be replaced by prosthetic means. Majority were keen in getting them replaced mainly for the comfort in mastication. Although 77.9 and 32.9% were aware of the removable prostheses and implants respectively, only 25.2% knew about tooth supported bridges as an option of replacement of missing teeth. Participants' awareness on tooth and implant supported prostheses is at a higher level. Participants' opinion on need of regular dental visit was statistically significant when gender, ethnicity and education level were considered. The highest demand for replacement of missing teeth was observed in Kennedy class I and II situations in both upper and lower arches. Demand for fixed prostheses was significantly highest in Kennedy class II in upper and lower arches. In conclusion, although removable prosthodontic options are known to most of the patients, their awareness on tooth and implant supported prostheses is also at a higher level. The highest demand for replacement of missing teeth is by patients with Kennedy class I and II situations whereas Kennedy class II being the category with highest demand for fixed prostheses. We recommend that the location of missing teeth to be considered as a priority when educating patients on the most appropriate prosthetic treatment options. Dentists' involvement in educating patients on prosthetic options needs to be improved.

  8. Metabolic Pattern of Asymptomatic Hip-Prosthesis by 18F-FDG-Positron-Emission-Tomography

    International Nuclear Information System (INIS)

    Beslic, Nermina; Heber, Daniel; Walter Lipp, Rainer; Sonneck-Koenne, Charlotte; Knoll, Peter; Mirzaei, Siroos

    2015-01-01

    Joint replacement is a procedure with a major impact on the quality of life of patients with joint degenerative disease or traumatic injuries. However, some patients develop symptoms after the intervention caused by mechanical loosening or infection. Metabolic imaging by 18F-FDG-PET investigated in these patients isoften hampered by low specificity for diagnosis of possible septic vs. mechanical loosening. The reason for this shortcoming is to our opinion the unawareness of physiological remodeling processes that could be seen in asymptomatic patients. In order to overcome this drawback, we aimed to find out the physiological metabolic functional pattern in asymptomatic patients with implanted hip prosthesis Twelve patients (6 males, 6 females); mean age 73 ± 7 (range 58 - 91) years were prospectively enrolled in the study. The patients were admitted to our department for oncological referral with implanted hip prostheses. All patients explained no symptoms with regard to their implanted prosthesis. The attenuation corrected images were used for analysis. Fourteen hip prostheses in 12 patients were visually analyzed. Seven out of 14 prostheses among 12 patients showed focal periprosthetic enhanced metabolism, two of which showed two sites of enhanced uptake; whereas, the remaining five prostheses showed singular hypermetabolic areas within the periprosthetic site. The remaining seven prostheses in the other five patients showed no periprosthetic-enhanced uptake. Of the asymptomatic patients investigated, 58% showed focal enhanced periprosthetic glucose metabolism. This finding should be taken into consideration as a more probable unspecific metabolic pattern for correct interpretation of 18F-FDG-PET studies in patients with suspected septic loosening of the hip prosthesis

  9. Bone-anchored titanium implants for auricular rehabilitation: case report and review of literature

    Directory of Open Access Journals (Sweden)

    Emne Hammoud Gumieiro

    Full Text Available CONTEXT AND OBJECTIVE: Osseointegrated implants have acquired an important role in the prosthetic rehabilitation of patients with craniofacial defects. The main indications are lack of local tissue for autogenous reconstruction, previous reconstruction failure and selection of this technique by the patient. This paper presents a clinical case and discusses indications and advantages of the osseointegrated implant technique for retention of auricular prostheses. TYPE OF STUDY: Case report, Universidade Federal de São Paulo (UNIFESP. METHODS: A female patient received three auricular implants after surgical resection of a hemangioma in her left ear. The time taken for osseointegration of the temporal bone was three months. After fabrication of the implant-retained auricular prosthesis, the patient was monitored for 12 months. RESULTS: The clinical parameters evaluated showed good postoperative healing, healthy peri-implant tissue, good hygiene and no loss of implants. Good hygiene combined with thin and immobile peri-implant soft tissues resulted in minimal complications. Craniofacial implant integration appears to be site-dependent; increasing age affects osseointegration in the temporal bone. The frequency of adverse skin reactions in peri-implant tissues is generally low. CONCLUSION: The surgical technique for rehabilitation using implant-retained auricular prostheses seems to be simple. It is associated with low rates of adverse skin reactions and long-term complications. Prostheses anchored by osseointegrated implants seem to provide better retention than do prostheses supported on spectacle frames, less risk of discoloration through the use of adhesives and better esthetic results than do prostheses anchored in the surgical cavity

  10. The Influence of Artificial Cervical Disc Prosthesis Height on the Cervical Biomechanics: A Finite Element Study.

    Science.gov (United States)

    Yuan, Wei; Zhang, Haiping; Zhou, Xiaoshu; Wu, Weidong; Zhu, Yue

    2018-05-01

    Artificial cervical disc replacement is expected to maintain normal cervical biomechanics. At present, the effect of the Prestige LP prosthesis height on cervical biomechanics has not been thoroughly studied. This finite element study of the cervical biomechanics aims to predict how the parameters, like range of motion (ROM), adjacent intradiscal pressure, facet joint force, and bone-implant interface stress, are affected by different heights of Prestige LP prostheses. The finite element model of intact cervical spine (C3-C7) was obtained from our previous study, and the model was altered to implant Prestige LP prostheses at the C5-C6 level. The effects of the height of 5, 6, and 7 mm prosthesis replacement on ROM, adjacent intradiscal pressure, facet joint force, as well as the distribution of bone-implant interface stress were examined. ROM, adjacent intradiscal pressure, and facet joint force increased with the prosthesis height, whereas ROM and facet joint force decreased at C5-C6. The maximal stress on the inferior surface of the prostheses was greater than that on the superior surface, and the stresses increased with the prosthesis height. The biomechanical changes were slightly affected by the height of 5 and 6 mm prostheses, but were strongly affected by the 7-mm prosthesis. An appropriate height of the Prestige LP prosthesis can preserve normal ROM, adjacent intradiscal pressure, and facet joint force. Prostheses with a height of ≥2 mm than normal can lead to marked changes in the cervical biomechanics and bone-implant interface stress. Copyright © 2018 Elsevier Inc. All rights reserved.

  11. Comparison of in vivo polyethylene wear particles between mobile- and fixed-bearing TKA in the same patients.

    Science.gov (United States)

    Minoda, Yukihide; Hata, Kanako; Ikebuchi, Mitsuhiko; Mizokawa, Shigekazu; Ohta, Yoichi; Nakamura, Hiroaki

    2017-09-01

    Polyethylene wear particle generation is one of the most important factors that affects the mid- to long-term results of total knee arthroplasties (TKA). Mobile-bearing total knee prostheses were developed to reduce polyethylene wear generation. However, whether mobile-bearing prostheses actually generate fewer polyethylene wear particles than fixed-bearing prostheses remains controversial. The aim of this study was to compare, within individual patients, the in vivo polyethylene wear particles created by a newly introduced mobile-bearing prosthesis in one knee and a conventional fixed-bearing prosthesis in other knee. Eighteen patients receiving bilateral TKAs to treat osteoarthritis were included. The synovial fluid was obtained from 36 knees at an average of 3.5 years after the operation. The in vivo polyethylene wear particles were isolated from the synovial fluid using a previously validated method and examined using a scanning electron microscope and an image analyser. The size and shape of the polyethylene wear particles from the mobile-bearing prostheses were similar to those from the conventional fixed-bearing prostheses. Although the number of wear particles from the mobile-bearing prosthesis (1.63 × 10 7  counts/knee) appeared smaller than that from the fixed-bearing prosthesis (2.16 × 10 7  counts/knee), the difference was not statistically significant. The current in vivo study shows that no statistically significant differences were found between the polyethylene wear particles generated by a newly introduced mobile-bearing PS prosthesis and a conventional fixed-bearing PS prosthesis during the early clinical stage after implantation. Therapeutic study, Level III.

  12. All-ceramic or metal-ceramic tooth-supported fixed dental prostheses (FDPs)? A systematic review of the survival and complication rates. Part I: Single crowns (SCs).

    Science.gov (United States)

    Sailer, Irena; Makarov, Nikolay Alexandrovich; Thoma, Daniel Stefan; Zwahlen, Marcel; Pjetursson, Bjarni Elvar

    2015-06-01

    To assess the 5-year survival of metal-ceramic and all-ceramic tooth-supported single crowns (SCs) and to describe the incidence of biological, technical and esthetic complications. Medline (PubMed), Embase, Cochrane Central Register of Controlled Trials (CENTRAL) searches (2006-2013) were performed for clinical studies focusing on tooth-supported fixed dental prostheses (FDPs) with a mean follow-up of at least 3 years. This was complimented by an additional hand search and the inclusion of 34 studies from a previous systematic review [1,2]. Survival and complication rates were analyzed using robust Poisson's regression models to obtain summary estimates of 5-year proportions. Sixty-seven studies reporting on 4663 metal-ceramic and 9434 all-ceramic SCs fulfilled the inclusion criteria. Seventeen studies reported on metal-ceramic crowns, and 54 studies reported on all-ceramic crowns. Meta-analysis of the included studies indicated an estimated survival rate of metal-ceramic SCs of 94.7% (95% CI: 94.1-96.9%) after 5 years. This was similar to the estimated 5-year survival rate of leucit or lithium-disilicate reinforced glass ceramic SCs (96.6%; 95% CI: 94.9-96.7%), of glass infiltrated alumina SCs (94.6%; 95% CI: 92.7-96%) and densely sintered alumina and zirconia SCs (96%; 95% CI: 93.8-97.5%; 92.1%; 95% CI: 82.8-95.6%). In contrast, the 5-year survival rates of feldspathic/silica-based ceramic crowns were lower (pceramic and zirconia crowns exhibited significantly lower survival rates in the posterior region (pceramic fractures than metal-ceramic SCs (pceramic SCs than for metal-ceramic SCs. Survival rates of most types of all-ceramic SCs were similar to those reported for metal-ceramic SCs, both in anterior and posterior regions. Weaker feldspathic/silica-based ceramics should be limited to applications in the anterior region. Zirconia-based SCs should not be considered as primary option due to their high incidence of technical problems. Copyright © 2015 Academy

  13. Arthroplasty knee registry of Catalonia: What scientific evidence supports the implantation of our prosthesis?

    Science.gov (United States)

    Samaniego Alonso, R; Gaviria Parada, E; Pons Cabrafiga, M; Espallargues Carreras, M; Martinez Cruz, O

    2018-02-28

    In our environment, it is increasingly necessary to perform an activity based on scientific evidence and the field of prosthetic surgery should be governed by the same principles. The national arthroplasty registries allow us to obtain a large amount of data in order to evaluate this technique. The aim of our study is to analyse the scientific evidence that supports the primary total knee arthroplasties implanted in Catalonian public hospitals, based on the Arthoplasty Registry of Catalonia (RACat) MATERIAL AND METHODS: A review of the literature was carried out on knee prostheses (cruciate retaining, posterior stabilized, constricted and rotational) recorded in RACat between the period 2005-2013 in the following databases: Orthopedic Data Evaluation Panel, PubMed, TripDatabase and Google Scholar. The prostheses implanted in fewer than 10 units (1,358 prostheses corresponding to 62 models) were excluded. 41,947 prostheses (96.86%) were analysed out of 43,305 implanted, corresponding to 74 different models. In 13 models (n = 4,715) (11.24%) no clinical evidence to support their use was found. In the remaining 36 models (n = 13,609) (32.45%), level iv studies were the most predominant evidence. There was a significant number of implanted prostheses (11.24%) for which no clinical evidence was found. The number of models should be noted, 36 out of 110, with fewer than 10 units implanted. The use of arthroplasty registries has proved an extremely useful tool that allows us to analyse and draw conclusions in order to improve the efficiency of this surgical technique. Copyright © 2018 SECOT. Publicado por Elsevier España, S.L.U. All rights reserved.

  14. Próteses de comunicação e alinhamento comportamental sobre impressos hospitalares Communication prostheses and behavioral alignment in hospital leaflets

    Directory of Open Access Journals (Sweden)

    Paulo Roberto Vasconcellos-Silva

    2003-08-01

    graphic design, and emphasizes the priorities defined by the professionals. Such "communication prostheses" should be capable of electronic validation by means of software suitable for proportioning the "doses" to the subject matter. Information as a drug, cognitivism, the lack of research on message reception and the need for communicative action for the deconstruction of systems of closed thinking within the hospital environment have been discussed.

  15. Mastication improvement after partial implant-supported prosthesis use.

    Science.gov (United States)

    Gonçalves, T M S V; Campos, C H; Gonçalves, G M; de Moraes, M; Rodrigues Garcia, R C M

    2013-12-01

    Partially edentulous patients may be rehabilitated by the placement of removable dental prostheses, implant-supported removable dental prostheses, or partial implant fixed dental prostheses. However, it is unclear the impact of each prosthesis type over the masticatory aspects, which represents the objective of this paired clinical trial. Twelve patients sequentially received and used each of these 3 prosthesis types for 2 months, after which maximum bite force was assessed by a strain sensor and food comminution index was determined with the sieving method. Masseter and temporal muscle thicknesses during rest and maximal clenching were also evaluated by ultrasonography. Each maxillary arch received a new complete denture that was used throughout the study. Data were analyzed by analysis of variance for repeated measures, followed by the Tukey test (p mastication, and the magnitude of this effect was related to prosthesis type.

  16. Control and Evaluation of a Powered Transfemoral Prosthesis for Stair Ascent.

    Science.gov (United States)

    Ledoux, Elissa D; Goldfarb, Michael

    2017-07-01

    This paper assesses the metabolic effort exerted by three transfemoral amputees, when using a powered knee and ankle prosthesis for stair ascent, relative to ascending stairs with passive knee and ankle prostheses. The paper describes a controller that provides step-over stair ascent behavior reflective of healthy stair ascent biomechanics, and describes its implementation in a powered prosthesis prototype. Stair ascent experiments were performed with three unilateral transfemoral amputee subjects, comparing the oxygen consumption required to ascend stairs using the powered prosthesis (with a step-over gait), relative to using their daily-use energetically passive prostheses (with a step-to gait). Results indicate on average a 24% reduction in oxygen consumption and a 30% reduction in stair ascent timewhen using the powered prosthesis, relative to when using the passive prostheses. All subjects expressed a strong preference for ascending stairs using the powered prosthesis.

  17. Communication Protocol for Advanced Prosthesis Components

    OpenAIRE

    Karnå, David

    2007-01-01

    It would be of great value for the prosthesis industry to achieve an open standard for communication in upper limb prostheses. Cooperation between NTNU and the University of New Brunswick has resulted in a functional requirements specification for such a standard, SCIP(Standardised Communication Interface in Prostheses). The special challenges for communication in a prosthesis system are possible noisy environments, high demands for light weight, safety for the user and the fact that devices ...

  18. Proceedings of the Annual Conference on Manual Control (10th) held at Wright-Patterson AFB, Ohio on 9-11 April 1974

    Science.gov (United States)

    1974-04-01

    427 R. E. Fenton , R. D. Gilson, and R. W. Ventola Simulator Evaluation of Three Situation and Guidance Displays for V/STOL Zero-Zero Landings...prostheses is a factor that may lead some amputees to abandon their prostheses shortly after fitting, or to use them primarily for cosmetic purposes...PRESENTATION VIA DUAL KINESTHETIC-TACTUAL DISPLAYS lüTn w *rr ,-.-r Robert E. Fenton Richard D. 611 son Dept. of Electrical Engineering Dept. of

  19. A simple procedure for retrieval of a cement-retained implant-supported crown: a case report.

    Science.gov (United States)

    Buzayan, Muaiyed Mahmoud; Mahmood, Wan Adida; Yunus, Norsiah Binti

    2014-02-01

    Retrieval of cement-retained implant prostheses can be more demanding than retrieval of screw-retained prostheses. This case report describes a simple and predictable procedure to locate the abutment screw access openings of cementretained implant-supported crowns in cases of fractured ceramic veneer. A conventional periapical radiography image was captured using a digital camera, transferred to a computer, and manipulated using Microsoft Word document software to estimate the location of the abutment screw access.

  20. Towards photovoltaic powered artificial retina

    Directory of Open Access Journals (Sweden)

    Santiago Silvestre

    2011-11-01

    Full Text Available The aim of this article is to provide an overview of current and future concepts in the field of retinal prostheses, and is focused on the power supply based on solar energy conversion; we introduce the possibility of using PV minimodules as power supply for a new concept of retinal prostheses: Photovoltaic Powered Artificial Retina (PVAR. Main characteristics of these PV modules are presented showing its potential for this application.

  1. Clinical and patient-reported outcomes of zirconia-based implant fixed dental prostheses: Results of a prospective case series 5 years after implant placement.

    Science.gov (United States)

    Spies, Benedikt Christopher; Witkowski, Siegbert; Vach, Kirstin; Kohal, Ralf-Joachim

    2018-01-01

    To evaluate the clinical and patient-reported outcome of all-ceramic zirconia implant supported fixed dental prostheses (FDPs) 5 years after implant installation. Thirteen patients were treated with two terminally placed one-piece zirconia implants for a three-unit FDP each. The FDPs consisted of a CAD/CAM-fabricated zirconia framework over-pressed with a fluor-apatite veneering ceramic and were adhesively cemented. Survival and success were assessed by applying modified US Public Health Service (USPHS) criteria and preparation of Kaplan-Meier (KM) plots. Alpha and Bravo ratings were accepted for success (among others including small area veneer chippings and occlusal roughness), whereas Charlie ratings allowing for intra-oral correction (e.g., polishing) were accepted for survival. Furthermore, patient-reported outcome measures (PROMs) were analyzed with the help of visual analogue scales (VAS). Wilcoxon matched-pairs signed-rank test (USPHS criteria) and linear mixed models (PROMs) were used to evaluate time effects on response variables. All patients were available 61.8 ± 1.1 months after implant installation (53.6 ± 3.1 months after final prosthesis insertion). FDP survival was 100%. Significant incidence of veneer chipping (p = .0096) and occlusal roughness (p = .0019) was observed. Charlie rated extent of both phenomena resulted in a KM success estimate of 38.5% (95% CI: 14.1%-62.8%; seven FDPs with obvious roughness, three of them with extended veneer chipping). Compared with the pre-treatment assessments (30%-81% of satisfaction), all surveys at prosthetic delivery showed significantly improved VAS scores (66%-93%; p ≤ .038), except for speech (p = .341). Concerning function, esthetics and self-esteem, no decrease in satisfaction could be observed until the end of follow-up (90%-96%; p ≥ .057), whereas perception of sense (92%) and speech (95%) increased over time (p ≤ .030). Occurrence of technical complications did not correlate

  2. A Randomized Seven-Year Study on Performance of the Stemmed Metal M2a-Magnum and Ceramic C2a-Taper, and the Resurfacing ReCap Hip Implants

    DEFF Research Database (Denmark)

    Borgwardt, Arne; Borgwardt, Lotte; Zerahn, Bo

    2018-01-01

    BACKGROUND: The large-diameter metal-on-metal hip prostheses were expected to have low wear and reduced dislocation rate compared to the traditional metal-on-polyethylene implants. We compare 2 such prostheses, the ReCap resurfacing implant and the M2a-Magnum stemmed implant, with the C2a ceramic......-on-ceramic stemmed implant as to clinical performance, serum concentrations of prosthesis metals, and the durability of the implants in a randomized, controlled clinical trial at 7 years of follow-up. METHODS: All included patients had osteoarthritis. Preoperatively, the size of the implants was estimated from...... of the soft tissue adjacent to the implant as well as MRI with metal artifact reduction sequence (MARS-MRI) when indicated. RESULTS: One hundred fifty-two hips in 146 patients were included. The serum cobalt and chromium concentrations were significantly higher for the 2 metal-on-metal prostheses than...

  3. Osseointegrated implants and auricular defects: a case series study.

    Science.gov (United States)

    Wright, Robert F; Zemnick, Candice; Wazen, Jack J; Asher, Eric

    2008-08-01

    The objective of this study was to report on the survival rate of 16 patients treated with extraoral implants in the auricular region, analyze treatment outcomes, and discuss important clinical variables encountered during treatment. Sixteen patients who received extraoral dental implants to retain auricular prostheses between 1987 and 2003 were followed retrospectively. The variables recorded were gender, initial diagnosis, number and size of implants, implant placement date, age at implant placement, history of radiation to the treated field, abutment size, design of initial prosthesis, age of initial prosthesis (when a remake was indicated), date of prosthesis delivery, soft tissue response, grafting procedure, date of last follow-up, and complications. All patients were thoroughly evaluated presurgically by the reconstruction team, which consisted of prosthodontists, a facial prosthetist, and an otolaryngologist. Surgical templates were used for all patients. The criteria for success of the prostheses included marginal accuracy, overall stability and function, symmetry/position, texture, color stability, and patient acceptance. Thirty-nine implants were placed in 16 patients. All 16 patients were completely satisfied with their reconstructions. No surgical complications, implant failures, or prosthetic failures were encountered. Therefore, the survival rate was 100%. Three patients (18.75%) had grade 0, seven (43.75%) had grade 1, five (31.25%) had grade 2, and one (6.25%) had grade 3 soft tissue inflammation. The inflammation completely resolved in 7 of the 13 patients (54%) with hygiene reinforcement or soft tissue reduction. The survival rate for bone-anchored titanium implants and prostheses was 100%. Bone-anchored titanium implants provided the 16 patients in this study with a safe, reliable, adhesive-free method to anchor auricular prostheses with recovery of normal appearance. Under the guidance of an appropriate implant team, proper positioning of

  4. Conception, design and development of a low-cost intelligent prosthesis for one-sided transfemoral amputees

    Directory of Open Access Journals (Sweden)

    Wilson Carlos da Silva Júnior

    Full Text Available Introduction Modern transfemoral knee prostheses are designed to offer comfort and self-confidence to amputees. These prostheses are mainly based upon either a passive concept, with a damping system, or an active computational intelligent design to control knee motion during the swing phase. In Brazil, most lower extremity amputees are unable to afford modern prostheses due to their high cost. In this work, we present the conception, design and development of a low-cost intelligent prosthesis for one-sided transfemoral amputees. Methods The concept of the prosthesis is based on a control system with sensors for loads, which are installed on the amputee’s preserved leg and used as a mirror for the movement of the prosthesis. Mechanical strength analysis, using the Finite Element Method, electromechanical tests for the sensors and actuators and verification of data acquisition, signal conditioning and data transferring to the knee prosthesis were performed. Results The laboratory tests performed showed the feasibility of the proposed design. The electromechanical concept that was used enabled a controlled activation of the knee prosthesis by the two load cells located on the shoe sole of the preserved leg. Conclusions The electromechanical design concept and the resulting knee prosthesis show promising results concerning prosthesis activation during walking tests, thereby showing the feasibility of a reduced manufacturing cost compared to the modern prostheses available on the market.

  5. A novel osseointegrated percutaneous prosthetic system for the treatment of patients with transfemoral amputation: A prospective study of 51 patients.

    Science.gov (United States)

    Brånemark, R; Berlin, O; Hagberg, K; Bergh, P; Gunterberg, B; Rydevik, B

    2014-01-01

    Patients with transfemoral amputation (TFA) often experience problems related to the use of socket-suspended prostheses. The clinical development of osseointegrated percutaneous prostheses for patients with a TFA started in 1990, based on the long-term successful results of osseointegrated dental implants. Between 1999 and 2007, 51 patients with 55 TFAs were consecutively enrolled in a prospective, single-centre non-randomised study and followed for two years. The indication for amputation was trauma in 33 patients (65%) and tumour in 12 (24%). A two-stage surgical procedure was used to introduce a percutaneous implant to which an external amputation prosthesis was attached. The assessment of outcome included the use of two self-report questionnaires, the Questionnaire for Persons with a Transfemoral Amputation (Q-TFA) and the Short-Form (SF)-36. The cumulative survival at two years' follow-up was 92%. The Q-TFA showed improved prosthetic use, mobility, global situation and fewer problems (all p reported following treatment with osseointegrated percutaneous prostheses.

  6. Three-Dimensional Printed Prosthesis for Repair of Superior Canal Dehiscence.

    Science.gov (United States)

    Kozin, Elliott D; Remenschneider, Aaron K; Cheng, Song; Nakajima, Hideko Heidi; Lee, Daniel J

    2015-10-01

    Outcomes following repair of superior canal dehiscence (SCD) are variable, and surgery carries a risk of persistent or recurrent SCD symptoms, as well as a risk of hearing loss and vestibulopathy. Poor outcomes may occur from inadequate repair of the SCD or mechanical insult to the membranous labyrinth. Repair of SCD using a customized, fixed-length prosthesis may address current operative limitations and improve surgical outcomes. We aim to 3-dimensionally print customized prostheses to resurface or occlude bony SCD defects. Dehiscences were created along the arcuate eminence of superior semicircular canals in cadaveric temporal bones. Prostheses were designed and created using computed tomography and a 3-dimensional printer. The prostheses occupied the superior semicircular canal defect, reflected in postrepair computed tomography scans. This novel approach to SCD repair could have advantages over current techniques. Refinement of prosthesis design and materials will be important if this approach is translated into clinical use. © American Academy of Otolaryngology-Head and Neck Surgery Foundation 2015.

  7. Oral rehabilitation of patients after maxillectomy. A systematic review.

    Science.gov (United States)

    Dos Santos, D M; de Caxias, F P; Bitencourt, S B; Turcio, K H; Pesqueira, A A; Goiato, M C

    2018-05-01

    Patients who have maxillectomy can be rehabilitated with reconstructive surgery or obturator prostheses with or without osseointegratable implants. To identify studies on possible treatments in this group, we systematically searched the Scopus, Embase, PubMed/Medline, and Cochrane databases to collect data on patients' characteristics, radiotherapy, and results related to speech, swallowing, mastication or diet, chewing, aesthetics, and quality of life. Of the 1376 papers found, six were included, and one other was included after an additional search of references. A total of 252 patients were included, and of them, 86 had reconstructive surgery, 91 were treated with obturator prostheses, 39 had reconstructive surgery or obturator prostheses associated with implants, and 36 had reconstruction plus an obturator prosthesis. Data on radiotherapy were incomplete. There is a lack of consensus about the indication for rehabilitation, as the treatment must be based on the individual characteristics of each patient. Copyright © 2018 The British Association of Oral and Maxillofacial Surgeons. Published by Elsevier Ltd. All rights reserved.

  8. Assessment of dental implant stability by means of the electromechanical impedance method

    International Nuclear Information System (INIS)

    Boemio, Giovanni; Rizzo, Piervincenzo; Nardo, Luigi De

    2011-01-01

    Implant stability is a prerequisite for functional recovery in load-bearing prostheses. Robust, reliable and noninvasive methods to assess the bone interface of dental and orthopedic implants are increasingly demanded for clinical diagnosis and direct prognosis. In this paper, a study of the feasibility of a noninvasive method based on electromechanical impedance (EMI) to assess dental prostheses stability is presented. Two different dental screws were entrenched in polyurethane foams (Sawbones ® ) and immersed in a solution of nitric acid to allow material degradation, inversely simulating a bone healing process. This process was monitored by bonding a piezoceramic transducer (PZT) to the implant and measuring the admittance of the PZT over time. It was found that the PZT's conductance and the statistical features associated with its analysis were sensitive to the degradation of the foams and can be correlated to the Sawbones mechanical properties. The present study shows promising results and may pave the road towards an innovative approach for the noninvasive monitoring of implanted prostheses

  9. Indium-granulocyte scanning in the painful prosthetic joint

    International Nuclear Information System (INIS)

    Pring, D.J.; Henderson, R.G.; Keshavarzian, A.; Rivett, A.G.; Krausz, T.; Coombs, R.R.; Lavender, J.P.

    1986-01-01

    The value of indium-111-labeled granulocyte scanning to determine the presence of infection was assessed in 50 prosthetic joints (41 of which were painful) in 40 patients. Granulocytes were obtained from the patients' blood and labeled in plasma with indium 111 tropolonate. Abnormal accumulation of indium 111 in the region of the prosthesis was noted. Proven infection occurred in 11 prostheses, and all of the infections were detected by indium-111-labeled granulocyte scanning. Nineteen were not infected (including nine asymptomatic controls) and only two produced false-positive scans. This represents a specificity of 89.5%, sensitivity of 100%, and overall accuracy of 93.2%. These results compare favorably with plain radiography. There was no radiologic evidence of infection in three of the infected prostheses, and 10 of the noninfected prostheses had some radiologic features that suggested sepsis. We conclude that indium-granulocyte scanning can reliably detect or exclude infection in painful prosthetic joints and should prove useful in clinical management

  10. Perspectives of optic nerve prostheses.

    Science.gov (United States)

    Lane, Frank John; Nitsch, Kristian; Huyck, Margaret; Troyk, Philip; Schug, Ken

    2016-01-01

    A number of projects exist that are investigating the ability to restore visual percepts for individuals who are blind through a visual prosthesis. While many projects have reported the results from a technical basis, very little exists in the professional literature on the human experience of visual implant technology. The current study uses an ethnographic methodological approach to document the experiences of the research participants and study personnel of a optic nerve vision prosthesis project in Brussels, Belgium. The findings have implications for motivation for participating in clinical trials, ethical safeguards of participants and the role of the participant in a research study. Implications for Rehabilitation Rehabilitation practitioners are often solicited by prospective participants to assist in evaluating a clinical trial before making a decision about participation. Rehabilitation professionals should be aware that: The decision to participate in a clinical trial is ultimately up to the individual participant. However, participants should be aware that family members might experience stress from of a lack of knowledge about the research study. The more opportunities a participant has to share thoughts and feelings about the research study with investigators will likely result in a positive overall experience. Ethical safeguards put in place to protect the interests of an individual participant may have the opposite effect and create stress. Rehabilitation professionals can play an important role as participant advocates from recruitment through termination of the research study. Participant hope is an important component of participation in a research study. Information provided to participants by investigators during the consent process should be balanced carefully with potential benefits, so it does not destroy a participant's hope.

  11. Demonstration of metallic implants by means of digital luminescence radiography (DLR)

    International Nuclear Information System (INIS)

    Wiesmann, W.; Reiser, M.; Fiebich, M.; Bick, U.; Peters, P.E.

    1990-01-01

    DLR makes it possible to integrate conventional radiography into digital communication and storage methods (PACS) into radiology. The use of DLR has been compared with conventional film methods in the demonstration of hip prostheses. The high contrast differences at the edge of the metal implant leads to artifacts, which could result in erroneous interpretation. Suitable image manipulation makes it possible, however, to eliminate these artifacts almost completely. DLR leads to an improvement in diagnosis in those complications not specifically related to the prostheses. (orig.) [de

  12. A comparison of laser-welded titanium and conventional cast frameworks supported by implants in the partially edentulous jaw: a 3-year prospective multicenter study.

    Science.gov (United States)

    Jemt, T; Henry, P; Lindén, B; Naert, I; Weber, H; Bergström, C

    2000-01-01

    The purpose of this prospective multicenter study was to evaluate and compare the clinical performance of laser-welded titanium fixed partial implant-supported prostheses with conventional cast frameworks. Forty-two partially edentulous patients were provided with Brånemark system implants and arranged into 2 groups. Group A was provided with a conventional cast framework with porcelain veneers in one side of the jaw and a laser-welded titanium framework with low-fusing porcelain on the other side. The patients in group B had an old implant prosthesis replaced by a titanium framework prosthesis. The patients were followed for 3 years after prosthesis placement. Clinical and radiographic data were collected and analyzed. Only one implant was lost, and all prostheses were still in function after 3 years. The 2 framework designs showed similar clinical performance with few clinical complications. Only one abutment screw (1%) and 9 porcelain tooth units (5%) fractured. Four prostheses experienced loose gold screws (6%). In group A, marginal bone loss was similar for both designs of prostheses, with a mean of 1.0 mm and 0.3 mm in the maxilla and mandible, respectively. No bone loss was observed on average in group B. No significant relationship (P > 0.05) was observed between marginal bone loss and placement of prosthesis margin or prosthesis design. The use of laser-welded titanium frameworks seems to present similar clinical performance to conventional cast frameworks in partial implant situations after 3 years.

  13. Experimental Assessment of a New Type of Carbon-Coated ARTECOR® Vascular Prosthesis in Sheep

    Directory of Open Access Journals (Sweden)

    Jiří Podlaha

    2009-01-01

    Full Text Available The aim of the study was to test and verify the characteristics of a new type of carbon-coated ARTECOR® vascular prosthesis developed at the Knitting Research Institute, a.s. Brno. Eight healthy Merino sheep, aged between 2 and 3 years, were implanted four types (A, B, C with diamond-like carbon (DLC coating and D as a control without DLC of vascular prostheses. The site of implantation was the common carotid artery; the length of the implant was 7 cm. All sheep received antibiotics prophylactically in accordance with the theory of the so-called “protected coagulum”. Doppler ultrasound examination was performed before finishing the operation to verify the patency of each prosthesis. During the study period the animals were closely observed. Prostheses were extirpated on day +/- 100 in 6 sheep and on day 182 in 2 sheep. Type B prosthesis showed better results according to its postoperative patency. The implant lumen was constantly 7 mm, whereas the use of other types resulted in lumen narrowing. Type B prosthesis has a deposition of DLC coating of a thickness of 20 nm with a high content of sp3 bonds (more diamond-like ones. The experimental type B of prosthesis ARTECOR® appears to be the most successful of the tested prostheses (at the end of the study all B-type prostheses remained patent. This prosthesis appears to better satisfy the rheologic characteristics for healing.

  14. {sup 99m}Tc-HMPAO-labelled leucocyte scintigraphy in the diagnosis of infection after total knee replacement arthroplasty

    Energy Technology Data Exchange (ETDEWEB)

    Park, Dong Rib [College of Medicine, Kunkuk Univ., Seoul (Korea, Republic of); Kim, Jae Seung; Ryu, Jin Sook; Moon, Dae Hyuk; Bin, Seong Il; Cho, Woo Shin; Lee, Hee Kyung [College of Medicine, Ulsan Univ., Seoul (Korea, Republic of)

    1999-08-01

    This study was performed to evaluate the usefulness of {sup 99m}Tc-HMPAO-labelled leucocyte scintigraphy for diagnosing prosthetic infection after total knee replacement arthroplasty without the aid of following bone marrow scintigraphy. The study subjects were 25 prostheses of 17 patients (one man and 16 women, mean age: 65 years) who had total knee replacement arthroplasty. After injection of {sup 99m}Tc-HMPAO-labelled leucocyte, the whole body planar and knee SPECT images were obtained in all patients. The subjects were classified into three groups according to clinical suspicion of prosthetic infection: Group A (n=11) with high suspicion of infection; Group B (n=6) with equivocal suspicion of infection, and Group C (n=8) with asymptomatic contralateral prostheses. Final diagnosis of infection was based on surgical, histological and bacteriological data and clinical follow-up. Infection was confirmed in 13 prostheses (11 in Group A and 2 in Group B). All prostheses in Group A were true positive. There were two true positive, one false positive and three true negative in Group B, and six true negatives and two false positive in Group C. Overall sensitivity, specificity, and accuracy for diagnosis of the infected knee prosthesis were 100%, 75% and 88%, respectively. {sup 99m}Tc-HMPAO-labelled leucocyte scintigraphy is a sensitive method for the diagnosis of infected knee prosthesis. However, false positive uptakes even in asymptomatic prosthesis suggest that bone marrow scintigraphy may be needed to achieve improved specificity.

  15. 99mTc-HMPAO-labelled leucocyte scintigraphy in the diagnosis of infection after total knee replacement arthroplasty

    International Nuclear Information System (INIS)

    Park, Dong Rib; Kim, Jae Seung; Ryu, Jin Sook; Moon, Dae Hyuk; Bin, Seong Il; Cho, Woo Shin; Lee, Hee Kyung

    1999-01-01

    This study was performed to evaluate the usefulness of 99m Tc-HMPAO-labelled leucocyte scintigraphy for diagnosing prosthetic infection after total knee replacement arthroplasty without the aid of following bone marrow scintigraphy. The study subjects were 25 prostheses of 17 patients (one man and 16 women, mean age: 65 years) who had total knee replacement arthroplasty. After injection of 99m Tc-HMPAO-labelled leucocyte, the whole body planar and knee SPECT images were obtained in all patients. The subjects were classified into three groups according to clinical suspicion of prosthetic infection: Group A (n=11) with high suspicion of infection; Group B (n=6) with equivocal suspicion of infection, and Group C (n=8) with asymptomatic contralateral prostheses. Final diagnosis of infection was based on surgical, histological and bacteriological data and clinical follow-up. Infection was confirmed in 13 prostheses (11 in Group A and 2 in Group B). All prostheses in Group A were true positive. There were two true positive, one false positive and three true negative in Group B, and six true negatives and two false positive in Group C. Overall sensitivity, specificity, and accuracy for diagnosis of the infected knee prosthesis were 100%, 75% and 88%, respectively. 99m Tc-HMPAO-labelled leucocyte scintigraphy is a sensitive method for the diagnosis of infected knee prosthesis. However, false positive uptakes even in asymptomatic prosthesis suggest that bone marrow scintigraphy may be needed to achieve improved specificity

  16. FDG-PET for diagnosing prosthetic joint infection: systematic review and metaanalysis

    Energy Technology Data Exchange (ETDEWEB)

    Kwee, Thomas C. [University Medical Center Utrecht, Department of Radiology, Utrecht (Netherlands); Kwee, Robert M. [University Medical Center Maastricht, Department of Radiology, Maastricht (Netherlands); Alavi, Abass [Hospital of the University of Pennsylvania, Division of Nuclear Medicine, Philadelphia, PA (United States)

    2008-11-15

    The aim of this study was to systematically review and metaanalyze published data on the diagnostic performance of {sup 18}F-fluoro-2-deoxyglucose positron emission tomography (FDG-PET) in detecting prosthetic hip or knee joint infection. A systematic search for relevant studies was performed of the PubMed/MEDLINE and Embase databases. Two reviewers independently assessed the methodological quality of each study. A metaanalysis of the reported sensitivity and specificity of each study was performed. Subgroup analyses were performed if results of individual studies were heterogeneous. The inclusion criteria were met by 11 studies; there was a total sample size of 635 prostheses. Overall, the studies had good methodological quality. Pooled sensitivity and specificity of FDG-PET for the detection of prosthetic hip or knee joint infection were 82.1% (95%CI = 68.0-90.8%) and 86.6% (95%CI = 79.7-91.4%), respectively. Heterogeneity among the results of individual studies was present (I {sup 2} = 68.8%). Diagnostic performance was influenced by type of joint prostheses (hip prostheses vs. knee prostheses) and type of reconstruction method used (filtered back vs. iterative) (p = 0.0164 and p = 0.0235, respectively). In this metaanalysis, overall diagnostic performance of FDG-PET was moderate to high. Caution is warranted, however, because results of individual studies were heterogeneous and could not be fully explored. Future studies should further explore potential causes of heterogeneity and validate the use of FDG-PET for diagnosing prosthetic joint infection. (orig.)

  17. FDG-PET for diagnosing prosthetic joint infection: systematic review and metaanalysis

    International Nuclear Information System (INIS)

    Kwee, Thomas C.; Kwee, Robert M.; Alavi, Abass

    2008-01-01

    The aim of this study was to systematically review and metaanalyze published data on the diagnostic performance of 18 F-fluoro-2-deoxyglucose positron emission tomography (FDG-PET) in detecting prosthetic hip or knee joint infection. A systematic search for relevant studies was performed of the PubMed/MEDLINE and Embase databases. Two reviewers independently assessed the methodological quality of each study. A metaanalysis of the reported sensitivity and specificity of each study was performed. Subgroup analyses were performed if results of individual studies were heterogeneous. The inclusion criteria were met by 11 studies; there was a total sample size of 635 prostheses. Overall, the studies had good methodological quality. Pooled sensitivity and specificity of FDG-PET for the detection of prosthetic hip or knee joint infection were 82.1% (95%CI = 68.0-90.8%) and 86.6% (95%CI = 79.7-91.4%), respectively. Heterogeneity among the results of individual studies was present (I 2 = 68.8%). Diagnostic performance was influenced by type of joint prostheses (hip prostheses vs. knee prostheses) and type of reconstruction method used (filtered back vs. iterative) (p = 0.0164 and p = 0.0235, respectively). In this metaanalysis, overall diagnostic performance of FDG-PET was moderate to high. Caution is warranted, however, because results of individual studies were heterogeneous and could not be fully explored. Future studies should further explore potential causes of heterogeneity and validate the use of FDG-PET for diagnosing prosthetic joint infection. (orig.)

  18. Micromotion in knee arthroplasty. A roentgen stereophotogrammetric analysis of four different concepts of prosthetic fixation

    International Nuclear Information System (INIS)

    Ryd, L.

    1985-05-01

    In a prospective study, micromotion between tibial components and bone was analysed using roentgen stereophotogrammetric analysis (RSA), the potential of which was assessed. The patient material consisted of 96 arthrotic knees subjected to arthroplasty with six types of prosthese representing four different fixation concepts with and without bone cement. Provided stable conditions of the objects studied, RSA proved to have an accuracy (=resolution) of 0.3 degrees for rotation and 0.2 mm for translation (3 S.D.). This resolution was 10 times better than conventional radiography and sufficient for the study of micromotion. Micromotion, both gradual over time (migration) and instant, in response to applied forces (inducible displacement), was found for all tibial components studied. For conventional cemented prostheses the mean migration was 1-1.5 mm for the different groups. Most of the migration occurred during the first 6 months. Inducible displacement of 0.2-1.0 mm was found in most cases. Metal support did not improve the prosthetic fixation. For the non-cemented cases both migration and inducible displacement was significantly larger than in cemented cases. All prostheses proved to be bonded to the bone in a semi-rigid way permitting micromotion. The newer fixation concept did not prove superior to conventional cementing of all-polyethylene prostheses. The micromotion occurred wihtin the soft tissue layer constituing the radiolucent zone, which in some cases was of tensile origin. Other radiographic of clinical variables did not correlate with the micromotion. (Author)

  19. Dental onlay bridge-like prosthesis in three koalas (Phascolarctos cinereus): the use of Premise trimodal composite to prevent interproximal Eucalyptus spp. retention and infection.

    Science.gov (United States)

    Perry, Sean M; Pye, Geoffrey W; Fagan, David A

    2014-06-01

    Three koalas (Phascolarctos cinereus) presented with moderate to severe interproximal space accumulation with Eucalyptus spp. at the San Diego Zoo. Premise trimodal composite was used to create dental onlay bridge-like prostheses to eliminate open, enlarged interproximal spaces. The prostheses prevented further leaf material accumulation within the interproximal spaces and consequently reduced periodontal disease. Aesthetically, the prosthesis replicates normal tooth coloration and appearance and wears at a similar rate to surrounding teeth. Prosthetic repair or replacement may be required, so periodic examination every 3-6 mo is recommended.

  20. Artificial organs versus regenerative medicine: is it true?

    Science.gov (United States)

    Nosé, Yukihiko; Okubo, Hisashi

    2003-09-01

    Individuals engaged in the fields of artificial kidney and artificial heart have often mistakenly stated that "the era of artificial organs is over; regenerative medicine is the future." Contrarily, we do not believe artificial organs and regenerative medicine are different medical technologies. As a matter of fact, artificial organs developed during the last 50 years have been used as a bridge to regeneration. The only difference between regenerative medicine and artificial organs is that artificial organs for the bridge to regeneration promote tissue regeneration in situ, instead of outside the body (for example, vascular prostheses, neuroprostheses, bladder substitutes, skin prostheses, bone prostheses, cartilage prostheses, ligament prostheses, etc.). All of these artificial organs are successful because tissue regeneration over a man-made prosthesis is established inside the patient's body (artificial organs to support regeneration). Another usage of the group of artificial organs for the bridge to regeneration is to sustain the functions of the patient's diseased organs during the regeneration process of the body's healthy tissues and/or organs. This particular group includes artificial kidney, hepatic assist, respiratory assist, and circulatory assist. Proof of regeneration of these healthy tissues and/or organs is demonstrated in the short-term recovery of end-stage organ failure patients (artificial organs for bridge to regeneration). A third group of artificial organs for the bridge to regeneration accelerates the regenerating process of the patient's healthy tissues and organs. This group includes neurostimulators, artificial blood (red cells) blood oxygenators, and plasmapheresis devices, including hemodiafiltrators. So-called "therapeutic artificial organs" fall into this category (artificial organs to accelerate regeneration). Thus, almost all of today's artificial organs are useful in the bridge to regeneration of healthy natural tissues and organs

  1. Functional outcome, revision rates and mortality after primary total hip replacement--a national comparison of nine prosthesis brands in England.

    Directory of Open Access Journals (Sweden)

    Mark Pennington

    Full Text Available The number of prosthesis brands used for hip replacement has increased rapidly, but there is little evidence on their effectiveness. We compared patient-reported outcomes, revision rates, and mortality for the three most frequently used brands within each prosthesis type: cemented (Exeter V40 Contemporary, Exeter V40 Duration and Exeter V40 Elite Plus Ogee, cementless (Corail Pinnacle, Accolade Trident, and Taperloc Exceed, and hybrid (Exeter V40 Trilogy, Exeter V40 Trilogy, and CPT Trilogy.We used three national databases of patients who had hip replacements between 2008 and 2011 in the English NHS to compare functional outcome (Oxford Hip Score (OHS ranging from 0 (worst to 48 (best in 43,524 patients at six months. We analysed revisions and mortality in 187,201 patients. We used multiple regression to adjust for pre-operative differences. Prosthesis type had an impact on post-operative OHS and revision rates (both p<0.001. Patients with hybrid prostheses had the best functional outcome (mean OHS 39.4, 95%CI 39.1 to 39.7 and those with cemented prostheses the worst (37.7, 37.3 to 38.1. Patients with cemented prostheses had the lowest reported 5-year revision rates (1.3%, 1.2% to 1.4% and those with cementless prostheses the highest (2.2%, 2.1% to 2.4%. Differences in mortality according to prosthesis type were small and not significant (p = 0.06. Functional outcome varied according to brand among cemented (p = 0.05, with Exeter V40 Duration having the best and cementless prostheses (p = 0.01, with Corail Pinnacle having the best. Revision rates varied according to brand among hybrids (p = 0.05, with Exeter V40 Trident having the lowest.Functional outcomes were better with cementless cups and revision rates were lower with cemented stems, which underlies the good overall performance of hybrids. The hybrid Exeter V40 Trident seemed to produce the best overall results. This brand should be considered as a benchmark in randomised trials.

  2. Impact of Powered Knee-Ankle Prosthesis on Low Back Muscle Mechanics in Transfemoral Amputees: A Case Series

    Directory of Open Access Journals (Sweden)

    Chandrasekaran Jayaraman

    2018-03-01

    Full Text Available Regular use of prostheses is critical for individuals with lower limb amputations to achieve everyday mobility, maintain physical and physiological health, and achieve a better quality of life. Use of prostheses is influenced by numerous factors, with prosthetic design playing a critical role in facilitating mobility for an amputee. Thus, prostheses design can either promote biomechanically efficient or inefficient gait behavior. In addition to increased energy expenditure, inefficient gait behavior can expose prosthetic user to an increased risk of secondary musculoskeletal injuries and may eventually lead to rejection of the prosthesis. Consequently, researchers have utilized the technological advancements in various fields to improve prosthetic devices and customize them for user specific needs. One evolving technology is powered prosthetic components. Presently, an active area in lower limb prosthetic research is the design of novel controllers and components in order to enable the users of such powered devices to be able to reproduce gait biomechanics that are similar in behavior to a healthy limb. In this case series, we studied the impact of using a powered knee-ankle prostheses (PKA on two transfemoral amputees who currently use advanced microprocessor controlled knee prostheses (MPK. We utilized outcomes pertaining to kinematics, kinetics, metabolics, and functional activities of daily living to compare the efficacy between the MPK and PKA devices. Our results suggests that the PKA allows the participants to walk with gait kinematics similar to normal gait patterns observed in a healthy limb. Additionally, it was observed that use of the PKA reduced the level of asymmetry in terms of mechanical loading and muscle activation, specifically in the low back spinae regions and lower extremity muscles. Further, the PKA allowed the participants to achieve a greater range of cadence than their predicate MPK, thus allowing them to safely

  3. The long-term use of zygomatic implants: a 10-year clinical and radiographic report.

    Science.gov (United States)

    Aparicio, Carlos; Manresa, Carolina; Francisco, Karen; Ouazzani, Wafaa; Claros, Pedro; Potau, Josep M; Aparicio, Arnau

    2014-06-01

    The zygoma implant has been an effective option in the short-term management of the atrophic edentulous maxilla. To report on long-term outcomes in the rehabilitation of the atrophic maxilla using zygomatic (ZI) and regular implants (RI). 22 consecutive zygomatic patients in a maintenance program were included. Cumulative survival rate (CSR) of ZI, RI, prostheses, and complications were recorded during, at least, 10 years of loading. Implant mobility was tested using Periotest(®). Sinus health was radiographically and clinically assessed according to Lund-Mackay (L-M) score and Lanza and Kennedy survey, respectively. A satisfaction questionnaire and anatomical measurements were also performed. Patients received 22 prostheses, anchored on 172 implants. Forty-one were ZI. Three RI failed (10 years CSR = 97.71%). Two ZI were partly removed due to perimplant infection (10 years CSR = 95.12%). All patients maintained functional prostheses. One patient fractured framework twice. Loosening or fracturing screws happened in 11 patients. Seven patients fractured occlusal material. Four ZI abutments in two patients were disconnected because of uncomfortable prostheses. Alveolar height at the ZI head level on the right and left sides was 2.64 mm and 2.25 mm, respectively. Mean distance of ZI head center to ridge center, on the right and left sides was 4.54 mm and 5.67 mm, respectively. Mean Periotest values (PTv) of ZI were -4.375 PTv and -4.941 PTv before prostheses placement and after 10 years, respectively. Six patients experienced sinusitis 14-127 months postoperatively. 54.55% of the L-M scores did not present opacification (L-M = 0) in any sinus. Osteomeatal obstruction happened in eight patients (two bilateral). Two (9.09%) were diagnosed with sinusitis. Eighty-four percent reported satisfaction levels above 80%. 31.81% reported maximum satisfaction score (100%). The long-term rehabilitation of the severely atrophic maxillae using ZI is a predictable procedure. © 2012

  4. Porcine carotid artery replacement with biodegradable electrospun poly-e-caprolactone vascular prosthesis.

    Science.gov (United States)

    Mrówczyński, Wojciech; Mugnai, Damiano; de Valence, Sarra; Tille, Jean-Christophe; Khabiri, Ebrahim; Cikirikcioglu, Mustafa; Möller, Michael; Walpoth, Beat H

    2014-01-01

    There is a continuous search for shelf-ready small-caliber vascular prostheses with satisfactory early and late results. Biodegradable scaffolds, repopulated by recipient's cells regenerating a neovessel, can be a suitable option for adult and pediatric, urgent and elective cardiovascular procedures. This was a short-term experimental assessment of a new biodegradable vascular prosthesis for arterial replacement in the pig. Eleven pigs underwent bilateral carotid artery replacement with biodegradable electrospun poly-ε-caprolactone (PCL) nanofiber prostheses (internal diameter, 4 mm; length, 5 cm); or expanded polytetrafluoroethylene (ePTFE) prostheses as control. Perioperative anticoagulation was achieved with intravenous heparin (double baseline activated clotting time). Postoperatively, until conclusion of the study at 1 month, animals received aspirin and clopidogrel daily. Transit time flow was measured intraoperatively and at sacrifice. Doppler ultrasound (1 and 4 weeks) and a selective carotid angiography (4 weeks) were performed to assess patency. All explanted grafts were analyzed by histology, morphometry, and scanning electron microscopy in order to study graft-host interaction. Surgical handling and hemostasis of the new prostheses were excellent. Patency rate was 78% (7/9) for PCL grafts, compared with 67% (4/6) for ePTFE grafts. Transit time flow and Doppler ultrasound showed no significant changes in flow and velocity or diameter over time in both groups. Both prostheses showed no detectable in vivo compliance as compared with native carotid artery. Percent neoendothelialization was 86% for PCL and 58% for ePTFE grafts (P = .008). Neointima formation was equal in both grafts. More adventitial infiltration of macrophages, myofibroblasts, and capillaries was seen in PCL grafts with a milder foreign-body reaction when compared with ePTFE implants. Both grafts showed similar endoluminal thrombus formation. Biodegradable, electrospun PCL grafts showed

  5. Maxillary Implant-Supported Fixed Prosthesis: A Survey of Reviews and Key Variables for Treatment Planning.

    Science.gov (United States)

    Gallucci, German O; Avrampou, Marianna; Taylor, James C; Elpers, Julie; Thalji, Ghadeer; Cooper, Lyndon F

    2016-01-01

    This review was conducted to provide information to support the establishment of clinical guidelines for the treatment of maxillary edentulism using implant-supported fixed dental prostheses. Initial efforts were directed toward a systematic review with a defined PICO question: "For maxillary edentulous patients with dental implants treated using a fixed prosthesis, what is the impact of prosthesis design on prosthesis survival and complications?" Following a title search of more than 3,000 titles identified by electronic search of PubMed, 180 articles were identified that addressed the clinical evaluation of maxillary dental implant prostheses. The broad methodologic heterogeneity and clinical variation among reports precluded this approach for a systematic review. The information was extracted using a standardized extraction table by two pairs of investigators, and the reported outcomes were then summarized according to reported outcomes for implant prostheses supported by four, six, or eight implants using unitary or segmented prostheses. This review indicated that high prosthetic survival is observed using all approaches. The advantages of using fewer implants and a unitary prosthesis are revealed in the surgical phases, and complications commonly involve the fracture or detachment of acrylic teeth and reduced access for proper oral hygiene and related biologic complications. Using six implants typically involved grafting of posterior regions with advantages of reduced cantilevers and redundancy of implant support. Reduced prosthesis survival in these cases was associated with poor implant distribution. Segmented prostheses supported by six or more implants offered greater prosthetic survival, perhaps due to posterior implant placement. Advantages of a segmented prosthesis included pragmatic issues of accommodating divergent implants, attaining passive fit, combining prosthetic materials, and relative simplicity of repair. The existing literature demonstrated

  6. All-ceramic or metal-ceramic tooth-supported fixed dental prostheses (FDPs)? A systematic review of the survival and complication rates. Part II: Multiple-unit FDPs.

    Science.gov (United States)

    Pjetursson, Bjarni Elvar; Sailer, Irena; Makarov, Nikolay Alexandrovich; Zwahlen, Marcel; Thoma, Daniel Stefan

    2015-06-01

    To assess the 5-year survival of metal-ceramic and all-ceramic tooth-supported fixed dental prostheses (FDPs) and to describe the incidence of biological, technical and esthetic complications. Medline (PubMed), Embase and Cochrane Central Register of Controlled Trials (CENTRAL) searches (2006-2013) were performed for clinical studies focusing on tooth-supported FDPs with a mean follow-up of at least 3 years. This was complemented by an additional hand search and the inclusion of 10 studies from a previous systematic review [1]. Survival and complication rates were analyzed using robust Poisson's regression models to obtain summary estimates of 5-year proportions. Forty studies reporting on 1796 metal-ceramic and 1110 all-ceramic FDPs fulfilled the inclusion criteria. Meta-analysis of the included studies indicated an estimated 5-year survival rate of metal-ceramic FDPs of 94.4% (95% CI: 91.2-96.5%). The estimated survival rate of reinforced glass ceramic FDPs was 89.1% (95% CI: 80.4-94.0%), the survival rate of glass-infiltrated alumina FDPs was 86.2% (95% CI: 69.3-94.2%) and the survival rate of densely sintered zirconia FDPs was 90.4% (95% CI: 84.8-94.0%) in 5 years of function. Even though the survival rate of all-ceramic FDPs was lower than for metal-ceramic FDPs, the differences did not reach statistical significance except for the glass-infiltrated alumina FDPs (p=0.05). A significantly higher incidence of caries in abutment teeth was observed for densely sintered zirconia FDPs compared to metal-ceramic FDPs. Significantly more framework fractures were reported for reinforced glass ceramic FDPs (8.0%) and glass-infiltrated alumina FDPs (12.9%) compared to metal-ceramic FDPs (0.6%) and densely sintered zirconia FDPs (1.9%) in 5 years in function. However, the incidence of ceramic fractures and loss of retention was significantly (p=0.018 and 0.028 respectively) higher for densely sintered zirconia FDPs compared to all other types of FDPs. Survival rates of all

  7. Cemented versus Uncemented Oxford Unicompartmental Knee Arthroplasty: Is There a Difference?

    Directory of Open Access Journals (Sweden)

    Burak Akan

    2013-01-01

    Full Text Available Purpose. The use of uncemented unicompartmental knee prostheses has recently increased. However, few studies on the outcomes of uncemented unicompartmental knee prostheses have been performed. The purpose of this study was to compare the outcomes of cemented and uncemented Oxford unicompartmental knee arthroplasty. Materials and Methods. This retrospective observational study evaluated the clinical and radiological outcomes of 263 medial Oxford unicompartmental prostheses (141 cemented, 122 uncemented implanted in 235 patients. The mean follow-up was 42 months in the cemented group and 30 months in the uncemented group. Results. At the last follow-up, there were no significant differences in the clinical results or survival rates between the two groups. However, the operation time in the uncemented unicompartmental knee arthroplasty group was shorter than that in the cemented unicompartmental knee arthroplasty group. In addition, the cost of uncemented arthroplasty was greater. Conclusion. Despite the successful midterm results in the uncemented unicompartmental knee arthroplasty group, a longer follow-up period is required to determine the best fixation mode.

  8. Biomechanical Considerations in the Design of High-Flexion Total Knee Replacements

    Directory of Open Access Journals (Sweden)

    Cheng-Kung Cheng

    2014-01-01

    Full Text Available Typically, joint arthroplasty is performed to relieve pain and improve functionality in a diseased or damaged joint. Total knee arthroplasty (TKA involves replacing the entire knee joint, both femoral and tibial surfaces, with anatomically shaped artificial components in the hope of regaining normal joint function and permitting a full range of knee flexion. In spite of the design of the prosthesis itself, the degree of flexion attainable following TKA depends on a variety of factors, such as the joint’s preoperative condition/flexion, muscle strength, and surgical technique. High-flexion knee prostheses have been developed to accommodate movements that require greater flexion than typically achievable with conventional TKA; such high flexion is especially prevalent in Asian cultures. Recently, computational techniques have been widely used for evaluating the functionality of knee prostheses and for improving biomechanical performance. To offer a better understanding of the development and evaluation techniques currently available, this paper aims to review some of the latest trends in the simulation of high-flexion knee prostheses.

  9. Differences of oral health conditions between adults and older adults: A census in a Southern Brazilian city.

    Science.gov (United States)

    Boscato, Noeli; Schuch, Helena S; Grasel, Claudia E; Goettems, Marilia L

    2016-09-01

    To assess differences in the oral diseases/conditions between adults and older adults. A cross-sectional study was carried out with all adults and older adults in Luzerna, South Brazil (n = 569). Clinical data included use of and need for dental prostheses; number of decayed, missing and filled teeth; and temporomandibular disorder. Differences between adults and older adults were evaluated using χ(2) -tests. Associations between independent variables and the use of and need for dental prostheses were determined using Poisson regression analyses (P older adults. After adjustments, lower social class (P = 0.001) and unmarried status (P = 0.05) were associated with greater need for prosthetic rehabilitation. Women (P = 0.02), older individuals (P adults and older adults was observed. The frequency of use of and need for dental prostheses was higher for older adults, although they had reported lower frequency of temporomandibular disorder. Women, married and individuals of higher socioeconomic status showed better oral health conditions. Geriatr Gerontol Int 2016; 16: 1014-1020. © 2015 Japan Geriatrics Society.

  10. Combination of natural teeth and osseointegrated implants as prosthesis abutments in a posterior cantilever bridge

    Directory of Open Access Journals (Sweden)

    Michael Josef Kridanto Kamadjaja

    2008-06-01

    Full Text Available Dental implants have been used for several decades. Patients of all ages have chosen dental implants to replace a single tooth or several teeth or to support partial or full dentures. This paper reports two cases of patients treated with dental implant as alternative to replace the missing teeth and connected with natural tooth as abutments in a fixed restoration with distal cantilever bridge. The underlining reasons that we decided to make such kind fixed prostheses are because of clinically imposible to put the implant on certain area and the patients asked for prostheses as optimum as possible, so the mastication function could return to the homeostasis condition. The benefit of these treatments are that prostheses could be made as optimum as possible with a more economic price, so the patients feel quite satisfied. The result shows that a few years after the treatments finished there is no any disadvantageous effect of connecting teeth to implants as abutments in fixed partial dentures and there is no sign of a harmful effect to the opposing teeth either.

  11. The acetabulum: A prospective study of three-phase bone and indium white blood cell scintigraphy following porous-coated hip arthroplasty

    International Nuclear Information System (INIS)

    Oswald, S.G.; Van Nostrand, D.; Savory, C.G.; Anderson, J.H.; Callaghan, J.J.

    1990-01-01

    Although few studies address the use of three-phase bone scanning (TPBS) and indium-111-labeled white blood cell scintigraphy ( 111 In-WBC) in hip arthroplasty utilizing a porous-coated prosthesis, the literature suggests that scintigraphic patterns in the uncomplicated patient may differ from that seen with the cemented prosthesis. In an attempt to determine the scintigraphic natural history, 25 uncomplicated porous-coated hip arthroplasties in 21 patients were prospectively studied with serial TPBS and 111I n-WBC at approximately 7 days, and 3, 6, 12, 18, and 24 mo postoperatively. This report deals with findings related to the acetabulum. All 25 prostheses (144 of 144 scans) demonstrated increased uptake on the bone-phase images. Although this activity decreased with time, 76% had persistent uptake at 24 mo. Twenty-three of 25 prostheses (126 of 140 scans) showed increased uptake on 111 In-WBC scintigraphy, invariably decreasing with time, but with 37% having significant uptake at 24 mo. Scintigraphic patterns in the uncomplicated porous-coated hip arthroplasty patient appear to differ from patterns described in cemented prostheses

  12. A silver ion-doped calcium phosphate-based ceramic nanopowder-coated prosthesis increased infection resistance.

    Science.gov (United States)

    Kose, Nusret; Otuzbir, Ali; Pekşen, Ceren; Kiremitçi, Abdurrahman; Doğan, Aydin

    2013-08-01

    Despite progress in surgical techniques, 1% to 2% of joint arthroplasties become complicated by infection. Coating implant surfaces with antimicrobial agents have been attempted to prevent initial bacterial adhesion to implants with varying success rates. We developed a silver ion-containing calcium phosphate-based ceramic nanopowder coating to provide antibacterial activity for orthopaedic implants. We asked whether titanium prostheses coated with this nanopowder would show resistance to bacterial colonization as compared with uncoated prostheses. We inserted titanium implants (uncoated [n = 9], hydroxyapatite-coated [n = 9], silver-coated [n = 9]) simulating knee prostheses into 27 rabbits' knees. Before implantation, 5 × 10(2) colony-forming units of Staphylococcus aureus were inoculated into the femoral canal. Radiology, microbiology, and histology findings were quantified at Week 6 to define the infection, microbiologically by increased rate of implant colonization/positive cultures, histologically by leukocyte infiltration, necrosis, foreign-body granuloma, and devitalized bone, and radiographically by periosteal reaction, osteolysis, or sequestrum formation. Swab samples taken from medullary canals and implants revealed a lower proportion of positive culture in silver-coated implants (one of nine) than in uncoated (eight of nine) or hydroxyapatite-coated (five of nine) implants. Silver-coated implants also had a lower rate of colonization. No cellular inflammation or foreign-body granuloma was observed around the silver-coated prostheses. Silver ion-doped ceramic nanopowder coating of titanium implants led to an increase in resistance to bacterial colonization compared to uncoated implants. Silver-coated orthopaedic implants may be useful for resistance to local infection but will require in vivo confirmation.

  13. A randomized controlled clinical trial of 3-unit posterior zirconia-ceramic fixed dental prostheses (FDP) with layered or pressed veneering ceramics: 3-year results.

    Science.gov (United States)

    Naenni, Nadja; Bindl, Andreas; Sax, Caroline; Hämmerle, Christoph; Sailer, Irena

    2015-11-01

    The aim of the present pilot study was to test whether or not posterior zirconia-ceramic fixed dental prostheses (FDPs) with pressed veneering ceramic exhibit less chipping than FDPs with layered veneering ceramics. Forty patients (13 female, 27 male; mean age 54 years (range 26.1-80.7 years) in need of one maxillary or mandibular three-unit FDP in the second premolar or molar region were recruited and treated at two separate centers at the University of Zurich according to the same study protocol. The frameworks were made out of zirconia using a CAD/CAM system (Cerec Sirona, Bensheim, Germany). The patients were randomly assigned to either the test group (zirconia frameworks veneered with pressed ceramic; IPS e.max ZirPress, Ivoclar Vivadent AG, Schaan, Liechtenstein; n=20) or the control group (layered veneering ceramic; IPS e.max Ceram, Ivoclar Vivadent AG, Schaan, Liechtenstein; n=20). All FDPs were adhesively cemented and evaluated at baseline (i.e., cementation), at 6 months and at 1 and 3 years of clinical service. The survival of the reconstruction was recorded. The technical outcome was assessed using modified United States Public Health Services (USPHS) criteria. The biologic parameters analyzed at abutment teeth and analogous non-restored teeth included probing pocket depth (PPD), plaque control record (PCR), bleeding on probing (BOP), and tooth vitality (CO2). Data was descriptively analyzed and survival was calculated using Kaplan-Meier statistics. 36 patients (25 female, 11 male; mean age 52.3 years) with 18 test and 18 control FDPs were examined after a mean follow-up of 36 months (95% CI: 32.6-39.1 months). Comparison of groups was done by Crosstabulation showing even distribution of the respective restored teeth amidst the groups. Survival rate was 100% for both test and control FDPs. Chipping of the veneering ceramic tended to occur more frequently in test (n=8; 40%) than in control (n=4; 20%) FDPs, albeit not significantly (p=0.3). No further

  14. Geometric Evaluation of the Effect of Prosthetic Rehabilitation on the Facial Appearance of Mandibulectomy Patients: A Preliminary Study.

    Science.gov (United States)

    Aswehlee, Amel M; Elbashti, Mahmoud E; Hattori, Mariko; Sumita, Yuka I; Taniguchi, Hisashi

    The purpose of this study was to geometrically evaluate the effect of prosthetic rehabilitation on the facial appearance of mandibulectomy patients. Facial scans (with and without prostheses) were performed for 16 mandibulectomy patients using a noncontact three-dimensional (3D) digitizer, and 3D images were reconstructed with the corresponding software. The 3D datasets were geometrically evaluated and compared using 3D evaluation software. The mean difference in absolute 3D deviations for full face scans was 382.2 μm. This method may be useful in evaluating the effect of conventional prostheses on the facial appearance of individuals with mandibulectomy defects.

  15. Arthrography of painful hips following arthroplasty: Digital versus plain film subtraction

    Energy Technology Data Exchange (ETDEWEB)

    Walker, C W; FitzRandolph, R L; Dalrymple, G V [Arkansas Univ. for Medical Sciences, Little Rock, AR (USA). Dept. of Radiology John McClellan Memorial Veterans Hospital, Little Rock, AR (USA); Collins, D N [Arkansas Univ. for Medical Sciences, Little Rock, AR (USA). Dept. of Orthopedics John McClellan Memorial Veterans Hospital, Little Rock, AR (USA)

    1991-08-01

    Digital and manual subtraction images obtained during the arthrographic evaluation of 78 painful hip prostheses were reviewed retrospectively. Revision arthroplasty was performed in 53 of these cases, and the arthrographic and surgical findings were correlated. The digital and manual subtraction images were evaluated without knowledge of the surgical results using established criteria for component loosening. The difference between detection of femoral component loosening on digital as opposed to manual subtraction images was statistically significant (P < 0.05). This study demonstrates that digital subtraction improves the evaluation of femoral component loosening in painful hip prostheses. (orig./GDG).

  16. Three-component hydraulic penile prosthesis malfunction due to penile fibrolipoma secondary to augmentative phalloplasty: A case report

    Directory of Open Access Journals (Sweden)

    Gabriele Antonini

    2016-01-01

    Full Text Available Fibrolipomas are an infrequent type of lipomas. We describe a case of a man suffering from subcutaneous penile fibrolipoma, who twelve months earlier has been submitted to augmentative phalloplasty due to aesthetic dysmorphophobia. The same patient three years earlier has been submitted to three-component hydraulic penile prostheses implantation due to erectile dysfunction. After six months from removing of the mass, the penile elongation and penile enlargement were stable, the prostheses were correctly functioning and the patient was satisfied with his sexual intercourse and life. The diagnostics and surgical characteristics of this case are reported.

  17. Pacemaker implantation rate after transcatheter aortic valve implantation with early and new-generation devices: a systematic review.

    Science.gov (United States)

    van Rosendael, Philippe J; Delgado, Victoria; Bax, Jeroen J

    2018-02-06

    The incidence of new-onset conduction abnormalities requiring permanent pacemaker implantation (PPI) after transcatheter aortic valve implantation (TAVI) with new-generation prostheses remains debated. This systematic review analyses the incidence of PPI after TAVI with new-generation devices and evaluates the electrical, anatomical, and procedural factors associated with PPI. In addition, the incidence of PPI after TAVI with early generation prostheses was reviewed for comparison. According to the Preferred Reporting Items for Systematic Reviews and Meta-Analyses checklist, this systematic review screened original articles published between October 2010 and October 2017, reporting on the incidence of PPI after implantation of early and new-generation TAVI prostheses. Of the 1406 original articles identified in the first search for new-generation TAVI devices, 348 articles were examined for full text, and finally, 40 studies (n = 17 139) were included. The incidence of a PPI after the use of a new-generation TAVI prosthesis ranged between 2.3% and 36.1%. For balloon-expandable prostheses, the PPI rate remained low when using an early generation SAPIEN device (ranging between 2.3% and 28.2%), and with the new-generation SAPIEN 3 device, the PPI rate was between 4.0% and 24.0%. For self-expandable prostheses, the PPI rates were higher with the early generation CoreValve device (16.3-37.7%), and despite a reduction in PPI rates with the new Evolut R, the rates remained relatively higher (14.7-26.7%). When dividing the studies according to the highest (>26.0%) and the lowest (left ventricular outflow tract (anatomical factor), and balloon valvuloplasty and depth of implantation (procedural factors) were associated with increased risk of PPI. The rate of PPI after TAVI with new-generation devices is highly variable. Specific recommendations for implantation of each prosthesis, taking into consideration the presence of pre-existent conduction abnormalities and

  18. The Toronto outcome measure for craniofacial prosthetics: reliability and validity of a condition-specific quality-of-life instrument.

    Science.gov (United States)

    Anderson, James D; Johnston, Dennis A; Haugh, Gil S; Kiat-Amnuay, Sudarat; Gettleman, Lawrence

    2013-01-01

    The purpose of this study was to refine the Toronto Outcome Measure for Craniofacial Prosthetics (TOMCP), present evidence for its reliability and validity, and use the instrument to explore differences in quality of life between prostheses made with chlorinated polyethylene (CPE) (experimental) and silicone (control). As part of a multicenter prospective controlled randomized double-blind single-crossover clinical trial of the two materials, the TOMCP was administered at the start and end of two 4-month study arms, during which 42 patients wore prostheses made from one material then the other. Reliability was assessed at the crossover. To determine validity of the TOMCP, the Linear Analogue Self-Assessment (LASA-12) and the Short-Form 8 (SF-8) were also administered with the TOMCP. The TOMCP was reduced by removing items that were unreliable, had poorly distributed answers, showed increased internal consistency after their removal, or were too highly correlated with more than one other item. The tests of reliability and validity were then repeated. Finally, the reduced instrument was used to test for differences in quality of life between prostheses made of the two materials. The item reduction tactics pared the 52-item instrument down to 27 items. The correlations of both TOMCP versions with the LASA-12 and the SF-8 were found to be statistically significant, providing evidence of the validity of the TOMCP. The instrument revealed significantly better quality of life with silicone rather than CPE prostheses. Both versions of the TOMCP were found to be reliable and valid. The instrument was able to show differences in quality of life between two materials.

  19. Clinical experiences with laser-welded titanium frameworks supported by implants in the edentulous mandible: a 10-year follow-up study.

    Science.gov (United States)

    Ortorp, Anders; Jemt, Torsten

    2006-01-01

    Long-term follow-up studies for more than 5 years are not available on laser-welded titanium frameworks. To report and compare 10-year data on implant-supported prostheses in the edentulous mandible provided with laser-welded titanium frameworks and conventional gold alloy frameworks. Altogether, 155 patients were consecutively treated with prostheses at abutment level with two generations of fixed laser-welded titanium frameworks (test groups). A control group of 53 randomly selected patients with conventional gold alloy castings was used for comparison. Clinical and radiographic 10-year data were collected for the three groups. All patients followed-up for 10 years (n=112) still had fixed prostheses in the mandible (cumulative success rate [CSR] 100%). The overall 10-year cumulative success rate (CSR) was 92.8 and 100.0% for titanium and gold alloy frameworks, respectively. Ten-year implant cumulative survival rate (CSR) was 99.4 and 99.6% for the test and control groups, respectively. Average 10-year bone loss was 0.56 (SD 0.45) mm for the titanium group and 0.77 (SD 0.36) mm for the control group (p screw components were below 3%. Excellent overall long-term results with 100% CSR could be achieved with the present treatment modality. Fractures of the metal frames and remade prostheses were more common for the laser-welded titanium frameworks, and the first generation of titanium frameworks worked poorly when compared with gold alloy frameworks during 10 years (p < 0.05). However, on average more bone loss was observed for implants supporting gold alloy frameworks during 10 years. The reasons for this difference are not clear.

  20. Rehabilitation with ear prosthesis linked to osseointegrated implants.

    Science.gov (United States)

    Goiato, Marcelo C; dos Santos, Daniela M; Haddad, Marcela F; Moreno, Amália

    2012-06-01

    The absence of an ear, which can be the result of a congenital malformation, surgical tumour resection or traumatic injury, is a significant aesthetic problem. Attachment of ear prostheses with adhesives can cause local irritation for the wearer and affect the colour of the prostheses. Use of implants in craniofacial reconstruction can improve the retention and stability of prostheses giving to patient greater comfort and security relative to adhesive attachment. The aim of this report was to present a clinical case of a mutilated patient who was rehabilitated by means of installing an ear prosthesis fixed through osseointegrated implants. The patient had two implants installed in the mastoid region that were linked by a bar, and a clip-type system was used. The ear prosthesis was constructed from medical-use silicone, pigmented to match the patient's skin colour and linked to the retention system. The patient's rehabilitation was satisfactory from both a functional and an aesthetic point of view, making it possible for the patient to return to a normal social life and regain lost self-esteem. © 2012 The Gerodontology Society and John Wiley & Sons A/S.

  1. [Individualized restorative designs and clinical evaluation for dental implants in the anterior esthetic zone with inappropriate conditions].

    Science.gov (United States)

    Dai, Wen-yong; Zhou, Guo-xing; Zhang, Xiao-zhen; Zhao, Yi; Wang, Jie; Yang, Yi; Zhu, Zhi-jun; Tang, Chun-bo

    2014-08-01

    To offer individualized restorative strategies for patients receiving dental implants in the anterior esthetic zone but with inappropriate available conditions and evaluate the clinical outcomes. Forty-six patients with 58 implants were recruited for the study in accordance with the criteria and received individualized implant prostheses in the anterior esthetic zone. The patients were followed up for 3-24 months, and the clinical outcomes were evaluated by pink and white esthetic scores (PES/WES). The patients were from 18 to 69 years old, and followed up for 12.6 months in average. According to the third month follow-up esthetic scores, for PES, 1.72% of the patients got low scores, 44.83% got medium scores and 53.45% got high scores; For WES, 0% got low scores, 20.69% got medium scores and 79.31% got high scores. No implant failure or peri-implantitis occurred. Individualized restorative designs for implants in the esthetic zone can effectively improve the appearance of the prostheses which originally have no appropriate available space. Close follow-up and monitoring of the peri-implant soft tissue and proper oral hygiene instructions are important to ensure the conditions of the prostheses.

  2. Availability of Dental Prosthesis Procedures in Brazilian Primary Health Care

    Directory of Open Access Journals (Sweden)

    Maria Aparecida Gonçalves Melo Cunha

    2018-01-01

    Full Text Available Objectives. To describe dental prosthesis provision in the Brazilian public health service and report the performance of dental prosthesis procedures according to the Brazilian macroregions. Methods. A structured interview was conducted with senior-level health professionals from each of the 18,114 oral health teams (OHT. The dependent variables were performance of removable prostheses and prosthesis procedures, including provision of fixed prostheses by OHT. Descriptive statistics were produced together with performing a cluster analysis using SPSS version 19.0. Results. The manufacture of any type of prosthesis was done by a minority of OHT (43%. The most commonly provided types of dental prosthesis were removable full and partial dentures. Cluster 1 (teams that performed prosthesis procedures the most was composed of a smaller number of teams (n = 5,531, and Cluster 2 (composed of teams that do not perform prosthetics or that perform them in small amounts consisted of 12,583 teams. The geographic distribution of clusters reveals that the largest proportion of Cluster 1 teams is located in the Northeast (33.9% and Southeast (33.6%. Conclusions. A minority of OHT produce dental prostheses. There is an unequal geographical distribution of clusters.

  3. Elements of implant-supported rehabilitation planning in patients with bruxism.

    Science.gov (United States)

    Sarmento, Hugo Ramalho; Dantas, Raquel Venâncio Fernandes; Pereira-Cenci, Tatiana; Faot, Fernanda

    2012-11-01

    The rehabilitation of partial or completely edentulous patients with implant-supported prostheses has been widely used, achieving high success rates. However, many studies consider the presence of bruxism as a contraindication for this treatment modality. The purpose of this study was to revise the literature and identify risk factors in implant-supported rehabilitation planning in subjects with bruxism. Available literature was searched through Medline, with no time limit, including only studies in English. Topics discussed were etiology of bruxism and its implications on dental implants, biomechanical considerations regarding the overload on dental implants, and methods to prevent the occurrence of overloads in implant-supported prostheses. The rehabilitation of bruxers using implant-supported prostheses, using implants with adequate length and diameter, as well as proper positioning seems to be a reliable treatment, with reduced risks of failure. Bruxism control through the use of a nightguard by rigid occlusal stabilization appliance relieved in the region of implants is highly indicated. Although it is clear that implant-supported rehabilitation of patients with bruxism requires adequate planning and follow-up, well-designed randomized controlled trials are needed to provide reliable evidence on the long-term success of this treatment modality.

  4. Monte Carlo characterization of materials for prosthetic implants and dosimetric validation of Pinnacle3 TPS

    International Nuclear Information System (INIS)

    Palleri, Francesca; Baruffaldi, Fabio; Angelini, Anna Lisa; Ferri, Andrea; Spezi, Emiliano

    2008-01-01

    In external beam radiotherapy the calculation of dose distribution for patients with hip prostheses is critical. Metallic implants not only degrade the image quality but also perturb the dose distribution. Conventional treatment planning systems do not accurately account for high-Z prosthetic implants heterogeneities, especially at interfaces. The materials studied in this work have been chosen on the basis of a statistical investigation on the hip prostheses implanted in 70 medical centres. The first aim of this study is a systematic characterization of materials used for hip prostheses, and it has been provided by BEAMnrc Monte Carlo code. The second aim is to evaluate the capabilities of a specific treatment planning system, Pinnacle 3 , when dealing with dose calculations in presence of metals, also close to the regions of high-Z gradients. In both cases it has been carried out an accurate comparison versus experimental measurements for two clinical photon beam energies (6 MV and 18 MV) and for two experimental sets-up: metallic cylinders inserted in a water phantom and in a specifically built PMMA slab. Our results show an agreement within 2% between experiments and MC simulations. TPS calculations agree with experiments within 3%.

  5. Monte Carlo characterization of materials for prosthetic implants and dosimetric validation of Pinnacle 3 TPS

    Science.gov (United States)

    Palleri, Francesca; Baruffaldi, Fabio; Angelini, Anna Lisa; Ferri, Andrea; Spezi, Emiliano

    2008-12-01

    In external beam radiotherapy the calculation of dose distribution for patients with hip prostheses is critical. Metallic implants not only degrade the image quality but also perturb the dose distribution. Conventional treatment planning systems do not accurately account for high-Z prosthetic implants heterogeneities, especially at interfaces. The materials studied in this work have been chosen on the basis of a statistical investigation on the hip prostheses implanted in 70 medical centres. The first aim of this study is a systematic characterization of materials used for hip prostheses, and it has been provided by BEAMnrc Monte Carlo code. The second aim is to evaluate the capabilities of a specific treatment planning system, Pinnacle 3, when dealing with dose calculations in presence of metals, also close to the regions of high-Z gradients. In both cases it has been carried out an accurate comparison versus experimental measurements for two clinical photon beam energies (6 MV and 18 MV) and for two experimental sets-up: metallic cylinders inserted in a water phantom and in a specifically built PMMA slab. Our results show an agreement within 2% between experiments and MC simulations. TPS calculations agree with experiments within 3%.

  6. Assessment of Oral Health Related Quality of Life Among the Institutionalised Elderly in Delhi, India.

    Science.gov (United States)

    Rekhi, Amit; Marya, Charu Mohan; Nagpal, Ruchi; Oberoi, Sukhvinder Singh

    To assess the oral health related quality of life (OHRQoL) among older people residing in old-age homes in Delhi, India. Oral health related quality of life was measured by using the Hindi version of Geriatric Oral Health Assessment Index (GOHAI) which was tested for its reliability and validity. Sociodemographic data were collected and questions regarding the self-perception of general health, oral health and perceived need for dental treatment were put forward. Clinical assessment was also performed. The mean additive-GOHAI score of the study population was found to be 41.57 ± 6.07. Statistically significant associations were found between GOHAI and perceived measures. GOHAI scores decreased with a decrease in the number of teeth present and a decrease in the number of teeth having coronal and root caries. Those subjects who were in need of multi-unit prostheses or full prostheses had significantly poorer OHRQoL compared to those without any prosthetic need or need of single-unit prostheses. This study revealed the extent of dental problems in old-age home residents and may help to plan appropriate preventive measures.

  7. Multimodality Treatment for Rehabilitation of Adult Orthodontic Patient with Complicated Dental Condition and Jaw Relation

    Directory of Open Access Journals (Sweden)

    Yu-Cheng Liaw

    2008-11-01

    Full Text Available A 50-year-old man with severe malocclusion requested comprehensive oral rehabilitation. He presented with retrognathic mandible, anterior deep bite and a gummy smile in the premaxilla, and tenting occlusal plane with severe buccal crossbite of the left maxillary posterior teeth. Inappropriate fixed prostheses spanned the maxilla and the mandible with a class II jaw relationship. A detailed analysis indicated the need for orthodontic treatment, orthognathic surgery, bone graft at the deficient alveolar ridge for implant surgery and a revision of all prostheses. Over a 2-year-period of management, the patient received anterior osteotomy for intrusion of lower anterior teeth, bilateral sagittal splitting osteotomy for mandible advancement and posterior osteotomy for inward upward repositioning of posterior teeth of the left maxilla to correct major jaw deformities. The deficient alveolar ridge in the premaxilla was augmented by autogenous bone graft harvested during the orthognathic surgery. He sequentially had mini-plate and dental implant as anchorage assisting teeth alignment in the mandible. Two 3-fixture-supported implant prostheses were delivered in the premaxilla and the mandible. The improvement in cosmesis, stability and function through treatment and a 2-year clinical follow-up were considered satisfactory.

  8. Economic Evaluation of Implant-Supported Overdentures in Edentulous Patients: A Systematic Review.

    Science.gov (United States)

    Zhang, Qi; Jin, Xin; Yu, Mengliu; Ou, Guoming; Matsui, Hiroyuki; Liang, Xing; Sasaki, Keiichi

    Edentulous patients benefit significantly from implant-supported overdenture prostheses. The purpose of this systematic review was to evaluate the cost-effectiveness of implant-supported overdentures (IODs) for edentulous patients. The search was limited to studies written in English and included an electronic and manual search through MEDLINE (Ovid, 1946 to November 2015), Embase (Ovid, 1966 to November 2015), Cochrane Central Register of Controlled Trials (CENTRAL) (to November 2015), and PubMed (to November 2015). Two investigators extracted the data and assessed the studies independently. No meta-analysis was conducted due to the high heterogeneity within the literature. Of the initial 583 selected articles, 10 studies involving 802 participants were included. Of these, 6 studies had a high risk of bias and the rest had an unclear risk of bias. Implant-supported prostheses were more cost-effective when compared to conventional dentures and fixed implant-supported prostheses. Overdentures supported by two implants and magnet attachment were reported as cost-effective. Implant-supported overdentures are a cost-effective treatment for edentulous patients. More clinical studies with appropriate scientific vigor are required to further assess the cost-effectiveness of implant-supported overdentures.

  9. [Possibility of 3D Printing in Ophthalmology - First Experiences by Stereotactic Radiosurgery Planning Scheme of Intraocular Tumor].

    Science.gov (United States)

    Furdová, A; Furdová, Ad; Thurzo, A; Šramka, M; Chorvát, M; Králik, G

    Nowadays 3D printing allows us to create physical objects on the basis of digital data. Thanks to its rapid development the use enormously increased in medicine too. Its creations facilitate surgical planning processes, education and research in context of organ transplantation, individualization prostheses, breast forms, and others.Our article describes the wide range of applied 3D printing technology possibilities in ophthalmology. It is focusing on innovative implementation of eye tumors treatment planning in stereotactic radiosurgery irradiation.We analyze our first experience with 3D printing model of the eye in intraocular tumor planning stereotactic radiosurgery. 3D printing, model, Fused Deposition Modelling, stereotactic radiosurgery, prostheses, intraocular tumor.

  10. Management of compromised anterior maxillary edentulous arch with symphyseal bone graft

    Directory of Open Access Journals (Sweden)

    Sunil Kumar Mishra

    2018-01-01

    Full Text Available Achieving optimal aesthetics, function and phonetics with implant-supported restorations depends largely on the amount of bone present at the site where implant has to be placed. Sometimes, patient reports with compromised conditions which makes the implant placement difficult. Today, reconstruction procedures such as autogenous bone graft and guided bone regeneration make the implant placement possible in different ridge deficient cases. This case report describes step-by-step procedure of restoring the missing maxillary right central incisor with implant-supported prostheses. In missing left central incisor region, the alveolar bony defect was corrected by autogenous bone graft obtained from symphysis region, for restoration with implant prostheses.

  11. Tribology of total hip arthroplasty prostheses

    OpenAIRE

    Rieker, Claude B.

    2016-01-01

    Articulating components should minimise the generation of wear particles in order to optimize long-term survival of the prosthesis. A good understanding of tribological properties helps the orthopaedic surgeon to choose the most suitable bearing for each individual patient. Conventional and highly cross-linked polyethylene articulating either with metal or ceramic, ceramic-on-ceramic and metal-on-metal are the most commonly used bearing combinations. All combinations of bearing surface have t...

  12. Echocardiographic Assessment of Heart Valve Prostheses

    Science.gov (United States)

    Sordelli, Chiara; Severino, Sergio; Ascione, Luigi; Coppolino, Pasquale; Caso, Pio

    2014-01-01

    Patients submitted to valve replacement with mechanical or biological prosthesis, may present symptoms related either to valvular malfunction or ventricular dysfunction from other causes. Because a clinical examination is not sufficient to evaluate a prosthetic valve, several diagnostic methods have been proposed to assess the functional status of a prosthetic valve. This review provides an overview of echocardiographic and Doppler techniques useful in evaluation of prosthetic heart valves. Compared to native valves, echocardiographic evaluation of prosthetic valves is certainly more complex, both for the examination and the interpretation. Echocardiography also allows discriminating between intra- and/or peri-prosthetic regurgitation, present in the majority of mechanical valves. Transthoracic echocardiography (TTE) requires different angles of the probe with unconventional views. Transesophageal echocardiography (TEE) is the method of choice in presence of technical difficulties. Three-dimensional (3D)-TEE seems to be superior to 2D-TEE, especially in the assessment of paravalvular leak regurgitation (PVL) that it provides improved localization and analysis of the PVL size and shape. PMID:28465917

  13. Wireless power delivery for retinal prostheses.

    Science.gov (United States)

    Ng, David C; Williams, Chris E; Allen, Penny J; Bai, Shun; Boyd, Clive S; Meffin, Hamish; Halpern, Mark E; Skafidas, Efstratios

    2011-01-01

    Delivering power to an implanted device located deep inside the body is not trivial. This problem is made more challenging if the implanted device is in constant motion. This paper describes two methods of transferring power wirelessly by means of magnetic induction coupling. In the first method, a pair of transmit and receive coils is used for power transfer over a large distance (compared to their diameter). In the second method, an intermediate pair of coils is inserted in between transmit and receive coils. Comparison between the power transfer efficiency with and without the intermediate coils shows power transfer efficiency to be 11.5 % and 8.8 %, respectively. The latter method is especially suitable for powering implanted devices in the eye due to immunity to movements of the eye and ease of surgery. Using this method, we have demonstrated wireless power delivery into an animal eye.

  14. Sensory feedback for upper limb prostheses.

    Science.gov (United States)

    Hsiao, Steven S; Fettiplace, Michael; Darbandi, Bejan

    2011-01-01

    In this chapter, we discuss the neurophysiological basis of how to provide sensory feedback to users with an upper limb prosthesis and discuss some of the theoretical issues that need to be considered when directly stimulating neurons in the somatosensory system. We focus on technologies that are currently available and discuss approaches that are most likely to succeed in providing natural perception from the artificial hand to the user. First, we discuss the advantages and disadvantages of providing feedback by stimulating directly the remaining afferents that originally innervated the arm and hand. In particular, we pay close attention to the normal functional roles that the peripheral afferents play in perception. What are the consequences and implications of stimulating these afferents? We then discuss whether it is reasonable to stimulate neurons in the ascending pathways that carry the information from the afferents to the cortex or directly in neurons in the primary somatosensory cortex. We show that for some modalities there are advantages for stimulating in the spinal cord, while for others it is advantageous to stimulate directly in the somatosensory cortex. Finally, we discuss results from a current experiment in which we used electrical stimuli in primary somatosensory cortex to restore the percept of the intensity of a mechanical probe indented into the hand. The results suggest that the simple percept of stimulus intensity can be provided to the animal from a single finger using four electrodes. We propose that significantly more electrodes will be needed to reproduce more complex aspects of tactile perception. Copyright © 2011 Elsevier B.V. All rights reserved.

  15. Inhibitory effect of zirconium oxide nanoparticles on Candida albicans adhesion to repaired polymethyl methacrylate denture bases and interim removable prostheses: a new approach for denture stomatitis prevention.

    Science.gov (United States)

    Gad, Mohammed M; Al-Thobity, Ahmad M; Shahin, Suliman Y; Alsaqer, Badar T; Ali, Aiman A

    2017-01-01

    addition of zirconia nanoparticles to cold-cured acrylic resin is an effective method for reducing Candida adhesion to repaired polymethyl methacrylate (PMMA) denture bases and cold-cured removable prosthesis. Based on the results of the current study, zirconia nanoparticles have an antifungal effect, which could be incorporated in the repair material for repairing denture bases and in PMMA removable prostheses as a possible approach for denture stomatitis prevention.

  16. Prevalência de lesões bucais associadas ao uso de próteses dentárias removíveis em um serviço de estomatologia Prevalencia de lesiones bucales asociadas al uso de prótesis dentales removibles, en un servicio de estomatología Prevalence of oral lesions associated with use of removable dental prostheses in a Stomatology service

    Directory of Open Access Journals (Sweden)

    Gardênia Matos Paraguassú

    2011-09-01

    candidiasis crónica atrófica en el 20,6 %, la queilitis angular en el 8,82 % y la úlcera traumática en el 8,82 %. Los sitios anatómicos más afectados fueron la mucosa alveolar con un 35,3 % y el paladar con un 29,4 %. Estos resultados subrayan la importancia del uso de prótesis adecuadas, así como la necesidad de realizar controles periódicos y de proporcionar instrucciones sobre la higiene bucal en pacientes que usan prótesis removibles.The removable dental prosthesis restores the function and esthetics of stomatognathic system but may to cause damages in oral tissues. The objective of present study is to assess the prevalence of oral lesions related to the use of removable prostheses. Authors made a review of records of patients seen in the Stomatology service of the Dentistry Faculty of Bahia Federal University of Brazil, from June, 2006 to December, 2007. From the 28 subjects using removable prostheses, 25 (89.3 % showed abnormalities in the buccal mucosa and the 42.8 % of them were not well adapted. The inflammatory fibrous hyperplasia (29.42 %, atrophic chronic candidiasis (20.6 %, angular cheilitis (8.82 % and traumatic ulcer (8.82 % were the more frequent lesions and the alveolar mucosa (35.3 % and palate (29.4 % were the anatomical sites more involved. These results emphasize la significance of an appropriate prosthesis, the need to make periodical controls and to give instructions on oral hygiene for patients that may use removable prostheses.

  17. Improving the Robustness of Electromyogram-Pattern Recognition for Prosthetic Control by a Postprocessing Strategy

    Directory of Open Access Journals (Sweden)

    Xu Zhang

    2017-09-01

    Full Text Available Electromyogram (EMG contains rich information for motion decoding. As one of its major applications, EMG-pattern recognition (PR-based control of prostheses has been proposed and investigated in the field of rehabilitation robotics for decades. These prostheses can offer a higher level of dexterity compared to the commercially available ones. However, limited progress has been made toward clinical application of EMG-PR-based prostheses, due to their unsatisfactory robustness against various interferences during daily use. These interferences may lead to misclassifications of motion intentions, which damage the control performance of EMG-PR-based prostheses. A number of studies have applied methods that undergo a postprocessing stage to determine the current motion outputs, based on previous outputs or other information, which have proved effective in reducing erroneous outputs. In this study, we proposed a postprocessing strategy that locks the outputs during the constant contraction to block out occasional misclassifications, upon detecting the motion onset using a threshold. The strategy was investigated using three different motion onset detectors, namely mean absolute value, Teager–Kaiser energy operator, or mechanomyogram (MMG. Our results indicate that the proposed strategy could suppress erroneous outputs, during rest and constant contractions in particular. In addition, with MMG as the motion onset detector, the strategy was found to produce the most significant improvement in the performance, reducing the total errors up to around 50% (from 22.9 to 11.5% in comparison to the original classification output in the online test, and it is the most robust against threshold value changes. We speculate that motion onset detectors that are both smooth and responsive would further enhance the efficacy of the proposed postprocessing strategy, which would facilitate the clinical application of EMG-PR-based prosthetic control.

  18. Retention systems for extraoral maxillofacial prosthetic implants: a critical review.

    Science.gov (United States)

    Cobein, M V; Coto, N P; Crivello Junior, O; Lemos, J B D; Vieira, L M; Pimentel, M L; Byrne, H J; Dias, R B

    2017-10-01

    We describe the techniques available for retention of implant-supported prostheses: bar-clips, O-rings, and magnets. We present reported preferences and, although this is limited by the heterogeneity of methods used and patients studied, we hope we have identified the best retention systems for maxillofacial prosthetic implants. If practitioners know the advantages and disadvantages of each system, they can choose the most natural and comfortable prosthesis. We searched the PubMed and Scopus databases, and restricted our search to papers published 2001-13. MeSH terms used were Maxillofacial prosthesis and Craniofacial prosthesis OR Craniofacial prostheses. We found a total of 2630 papers, and after duplicates had been removed we analysed the rest and found 25 papers for review. Of these, 12 were excluded because they were case reports or non-systematic reviews. Of the remaining 13, 10 described group analyses and seemed appropriate to find practitioner's choices, as cited in the abstract (n=1611 prostheses). Three papers did not mention the type of prosthetic connection used, so were excluded. The most popular choices for different conditions were analysed, though the sites and retention systems were not specified in all 10 papers. The bar-clip system was the most used in auricular (6/10 papers) and nasal prostheses (4/10). For the orbital region, 6/10 favoured magnets. Non-osseointegrated mechanical or adhesive retention techniques are the least expensive and have no contraindications. When osseointegrated implants are possible, each facial region has a favoured system. The choice of system is influenced by two factors: standard practice and the abilities of the maxillofacial surgeon and maxillofacial prosthetist. Copyright © 2017 The British Association of Oral and Maxillofacial Surgeons. Published by Elsevier Ltd. All rights reserved.

  19. The role of synovial fluid analysis in the detection of periprosthetic hip and knee infections: a systematic review and meta-analysis.

    Science.gov (United States)

    De Fine, Marcello; Giavaresi, Gianluca; Fini, Milena; Illuminati, Andrea; Terrando, Silvio; Pignatti, Giovanni

    2018-05-01

    This study tried to ascertain (1) the accuracy of synovial fluid white blood cell count and polymorphonucleate percentage in the diagnosis of periprosthetic hip and knee infections, (2) which test yielded superior test performance, and (3) the influence on diagnostic accuracy of study characteristics such as patient number, study design, study level, anatomic site, and threshold value. A systematic search was conducted including papers assessing more effective cutoffs for synovial fluid tests, having comparative design, evaluating an exclusive cohort of hip or knee prostheses, including a clear definition of infected cases, and reporting sufficient data for the calculation of true-positive, false-positive, false-negative, and true-negative. A total of 375 articles were collected and, given the inclusion criteria, ten manuscripts were included. These studies assessed 1155 hip prostheses (276 infected cases) and 1235 knee prostheses (401 infected cases). The specificity of synovial fluid white blood cell count was significantly increased by using the threshold value ≥ 3000 cell/μL (p = 0.006); the sensitivity of polymorphonucleate percentage was significantly higher in detecting knee infections (p = 0.034). Both tests had a high specificity and sensitivity in detecting periprosthetic joint infections, and no clear superiority of one over the other existed. Furthermore, cutoff and anatomic site significantly influenced synovial fluid white blood cell count and polymorphonucleate percentage, respectively. Synovial fluid analysis is adequate in differentiating patients with periprosthetic hip and knee infections. Our data confirms international guidelines suggesting the use of 3000 cell/μL as cutoff threshold for synovial fluid white blood cell count. Since an anatomic site effect has been demonstrated, the goal of future studies will be to identify different cutoffs for hip and knee prostheses.

  20. Gender differences of the morphology of the distal femur and proximal tibia in a Korean population.

    Science.gov (United States)

    Lim, Hong-Chul; Bae, Ji-Hoon; Yoon, Ji-Yeol; Kim, Seung-Ju; Kim, Jae-Gyoon; Lee, Jae-Moon

    2013-01-01

    We conducted this study to determine whether the sizes of distal femurs and proximal tibiae in Korean men and women are different, and to assess suitability of the sizes of prostheses currently used in Korea. We performed morphological analysis of proximal tibia and distal femur on 115 patients (56 male, 59 female) using MRI to investigate a gender difference. Tibial mediolateral dimension (tMAP), tibial medial anteroposterior dimension (tMAP), tibial lateral anteroposterior dimension (tLAP) femoral mediolateral dimension (fML), femoral medial anteroposterior dimension (fMAP), and femoral lateral anteroposterior dimension (fLAP) were measured. The ratio of tMAP and tLAP to tML (plateau aspect ratio, tAP/tML×100%), and that of fMAP and fLAP to fML (condylar aspect ratio, fAP/fML×100%) were calculated. The measurements were compared with the similar dimensions of four total knee implants currently used. The tML and tAP lengths showed a significant gender difference (PtMAP/tML) revealed a significant difference between male (0.74±0.05) and female (0.68±0.04, P<0.05). For morphotype of distal femur, males were found to have significantly large values (P<0.05) in the parameters, except for fLAP. With regards to the ratio of the ML width to the AP length, the women showed a narrower ML width than the men. Both genders were distributed within the range of the dimensions of the prostheses currently used prostheses. Korean population revealed that women have smaller dimensions than male counterparts. In both genders, a relatively small size of prostheses matches distal femur and proximal tibia better among the implants currently used in Korea. Copyright © 2012 Elsevier B.V. All rights reserved.

  1. Visual pattern and serial quantitation of {sup 18}F-sodium fluoride PET/CT in asymptomatic patients after hip and knee arthroplasty

    Energy Technology Data Exchange (ETDEWEB)

    Son, Hye Joo; Jeong, Young Jin; Yoon, Hyun Jin; Wang, Lih; Kim, Hyeon Jun; Kang, Do Young [Dong-A University Medical Center, Dong-A University College of Medicine, Busan (Korea, Republic of); Park, Jong Hwan [Institute of Convergence Bio-Health, Dong-A University, Busan (Korea, Republic of)

    2016-12-15

    We investigated the visual tracer distribution pattern and serial changes in uptake ratio in different anatomical zones during the natural postoperative course in order to establish a reference for evaluation of patients with complications. A total of 36 patients without symptoms after hip or knee arthroplasty were grouped according to the interval between surgery and the scan. The serial changes in SUVmean in each periprosthetic zone were quantified using the volume of interest isocontour method. Images were classified according to the uptake distribution pattern. The uptake ratios in the postoperative period groups were then compared using the Kruskal-Wallis test. The correlation between uptake ratio and postoperative period was then determined. Tracer distribution patterns in hip prostheses were classified into three types and the patterns in knee prostheses into five types. In hip prostheses, intense osteoblastic activity was observed during 3-6 months and then declined in most patients, but showed a slight increase over 15-25 months in 5-10 % of patients. The correlation coefficients varied among the zones. Significant differences in uptake ratios among the period groups was found for all zones, except zone 8. Porous coated areas showed higher uptake than uncoated areas only for the period the 3-6 months. In knee prostheses, uptake ratios showed a curvilinear pattern, increasing from 3-6 to 8-15 months and declining later. The uptake ratios were different among the period groups. Every zone showed a positive correlation from 3-6 to 8-15 months, and negative correlations from 8-15 to 22-25 months. This is the first {sup 18}F-sodium fluoride PET/CT study investigating the stability of implants and sets a reference for evaluation of patients with complications.

  2. [Non-cemented self-locking total arthroplasty of the hip. Clinical and radiological results after three years].

    Science.gov (United States)

    Desjardins, A L; Roy, A; Duchesne, R; Béliveau, P; Fallaha, M; Bornais, S

    1993-01-01

    We reviewed 47 patients who had fifty-one (51) primary, cementless biofit total hip arthroplasties (THA) implanted at Maisonneuve-Rosemont Hospital between 1986 and 1990. An independent observer rated the patients on the Harris Hip Score (HHS) by questionnaire, physical examination and radiological assessment. The average follow-up was 40 months. Twenty-two percent (22%) of the femoral components had been revised because of incapacitating pain, limping or a HHS inferior to 60. A little more than 20% of the unrevised prostheses had a mediocre result (HHS inferior to 70). There was no correlation between results and radiological signs of instability. The femoral component of the hip arthroplasty has a poor clinical performance which compares unfavourably with cemented prostheses.

  3. Complex radial folds versus subtle signs of intracapsular rupture of breast implants: MR findings with surgical correlation.

    Science.gov (United States)

    Soo, M S; Kornguth, P J; Walsh, R; Elenberger, C D; Georgiade, G S

    1996-06-01

    Detection of intracapsular rupture of silicone breast prostheses using MR imaging is often performed by identifying the "linguine sign" [1]. The linguine sign is easily differentiated from simple radial folds that are seen in intact implants. However, more subtle signs of intracapsular rupture, including undulating subcapsular lines and the "teardrop sign," are less often recognized [2-5] and may prove difficult for the less experienced radiologist to differentiate from complex radial folds of intact implants. In this essay, we illustrate the MR imaging findings of complex radial folds in intact implants and compare them with findings of incomplete shell collapse in ruptured implants in a surgically confirmed series of explanted silicone breast prostheses.

  4. Focused Ultrasound Surgery for Uterine Fibroids

    Science.gov (United States)

    ... or electronic devices inside your body, such as metallic joint prostheses, artificial heart valves, implanted electronic devices, cochlear implants, body piercings or dental implants. Other precautions The ...

  5. Arthrography

    Medline Plus

    Full Text Available ... examinations. Examples include but are not limited to: artificial heart valves implanted drug infusion ports artificial limbs or metallic joint prostheses implanted nerve stimulators ...

  6. Children's (Pediatric) Magnetic Resonance Imaging

    Medline Plus

    Full Text Available ... examinations. Examples include but are not limited to: artificial heart valves implanted drug infusion ports artificial limbs or metallic joint prostheses implanted nerve stimulators ...

  7. MRI of the Chest

    Medline Plus

    Full Text Available ... examinations. Examples include but are not limited to: artificial heart valves implanted drug infusion ports artificial limbs or metallic joint prostheses implanted nerve stimulators ...

  8. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... examinations. Examples include but are not limited to: artificial heart valves implanted drug infusion ports artificial limbs or metallic joint prostheses implanted nerve stimulators ...

  9. Biological biomaterials

    Energy Technology Data Exchange (ETDEWEB)

    Jorge-Herrero, E. [Servicio de Cirugia Experimental. Clinica Puerta de Hierro, Madrid (Spain)

    1997-05-01

    There are a number of situations in which substances of biological origin are employed as biomaterials. Most of them are macromolecules derived from isolated connective tissue or the connective tissue itself in membrane form, in both cases, the tissue can be used in its natural form or be chemically treated. In other cases, certain blood vessels can be chemically pretreated and used as vascular prostheses. Proteins such as albumin, collagen and fibrinogen are employed to coat vascular prostheses. Certain polysaccharides have also been tested for use in controlled drug release systems. Likewise, a number of tissues, such as dura mater, bovine pericardium, procine valves and human valves, are used in the preparation of cardiac prostheses. We also use veins from animals or humans in arterial replacement. In none of these cases are the tissues employed dissimilar to the native tissues as they have been chemically modified, becoming a new bio material with different physical and biochemical properties. In short, we find that natural products are being utilized as biomaterials and must be considered as such; thus, it is necessary to study both their chemicobiological and physicomechanical properties. In the present report, we review the current applications, problems and future prospects of some of these biological biomaterials. (Author) 84 refs.

  10. Major traumatic limb loss among women veterans and servicemembers.

    Science.gov (United States)

    Katon, Jodie G; Reiber, Gayle E

    2013-01-01

    The number of women veterans is rapidly growing, and little is known regarding the health and healthcare needs of women veterans with traumatic limb loss. The objective of this study was to summarize physical and mental health conditions and rates of prosthetic prescriptions among women service members and veterans with major traumatic limb loss. Researchers and clinicians who administered the Survey for Prosthetic Use contacted and enrolled 283 servicemembers and veterans of Operation Iraqi Freedom/Operation Enduring Freedom with major traumatic limb loss. Participants provided information on health status; comorbidities; other combat injuries; and prosthetic device use, rejection, and replacement. Of the 283 veterans, 9 (3%) were women. Compared with men, women reported more than a threefold higher prevalence of migraine (67% vs 20%, p = 0.001). Compared with men, women received 0.42 more prostheses per year, rejected 0.11 more prostheses per year, but replaced 0.18 fewer prostheses per year. With the exception of migraine headaches, men and women servicemembers and veterans with major traumatic limb loss report similarly high prevalence of physical and mental health conditions. Women report higher rates of prosthesis receipt and rejection and lower rates of prosthesis replacement than men. These findings highlight some potential issues specific to women veterans that may require additional clinical attention.

  11. Present status of titanium removable dentures--a review of the literature.

    Science.gov (United States)

    Ohkubo, C; Hanatani, S; Hosoi, T

    2008-09-01

    Although porcelain and zirconium oxide might be used for fixed partial dental prostheses instead of conventional dental metals in the near future, removable partial denture (RPD) frameworks will probably continue to be cast with biocompatible metals. Commercially pure (CP) titanium has appropriate mechanical properties, it is lightweight (low density) compared with conventional dental alloys, and has outstanding biocompatibility that prevents metal allergic reactions. This literature review describes the laboratory conditions needed for fabricating titanium frameworks and the present status of titanium removable prostheses. The use of titanium for the production of cast RPD frameworks has gradually increased. There are no reports about metallic allergy apparently caused by CP titanium dentures. The laboratory drawbacks still remain, such as the lengthy burn-out, inferior castability and machinability, reaction layer formed on the cast surface, difficulty of polishing, and high initial costs. However, the clinical problems, such as discoloration of the titanium surfaces, unpleasant metal taste, decrease of clasp retention, tendency for plaque to adhere to the surface, detachment of the denture base resin, and severe wear of titanium teeth, have gradually been resolved. Titanium RPD frameworks have never been reported to fail catastrophically. Thus, titanium is recommended as protection against metal allergy, particularly for large-sized prostheses such as RPDs or complete dentures.

  12. Radiation crosslinked hydrogels as sustained release drug delivery systems

    International Nuclear Information System (INIS)

    Pekala, W.; Rosiak, J.; Rucinska-Rybus, A.; Burczak, K.; Galant, S.; Czolczynska, T.

    1986-01-01

    Radiation methods have been used for: i/modification of vascular prostheses, ii/ obtaining burn dressing materials enabling controlled drug release, iii/ the preparation of polymer ocular insert discs. The surface of polyester vascular prostheses, has been modified by deposition of acrylamide and inducing its polymerization in the solid state by γ-radiation. As a result of this treatment, tightness of the prosthesis walls and its surface hydrophilicity have been improved. Toxicological examinations and blood hemolysis studies of modified prostheses showed its good biocompatibility. Various burn dressings have been prepared and the most promising of all investigated turned to be composition consisting of a cotton gauze base and an active polyacrylamide hydrogel layer with addition of glycerin and immobilized Provital/protein preparation/. Preliminary clinical evaluations of this particular dressing showed that the process of burn healing is indeed fast and fully satisfactory. Ocular insert discs made of polymer and containing pilocarpin hydrochloride which is released at controlled rate have been prepared. It has been found that high hydrophilicity and good swelling properties of the ocular insert discs made possible to incorporate pilocarpin hydrochloride into hydrogel matrix. This work has been carried out under IAEA research contract RB 3379/R-1 POL. (author)

  13. Safety and effectiveness considerations for clinical studies of visual prosthetic devices

    Science.gov (United States)

    Cohen, Ethan D.

    2007-03-01

    With the advent of new designs of visual prostheses for the blind, FDA is faced with developing guidance for evaluating their engineering, safety and patient performance. Visual prostheses are considered significant risk medical devices, and their use in human clinical trials must be approved by FDA under an investigation device exemption (IDE). This paper contains a series of test topics and design issues that sponsors should consider in order to assess the safety and efficacy of their device. The IDE application includes a series of pre-clinical and clinical data sections. The pre-clinical section documents laboratory, animal and bench top performance tests of visual prostheses safety and reliability to support a human clinical trial. The materials used in constructing the implant should be biocompatible, sterile, corrosion resistant, and able to withstand any forces exerted on it during normal patient use. The clinical data section is composed of items related to patient-related evaluation of device performance. This section documents the implantation procedure, trial design, statistical analysis and how visual performance is assessed. Similar to cochlear implants, a visual prosthesis is expected to last in the body for many years, and good pre-clinical and clinical testing will help ensure its safety, durability and effectiveness.

  14. Biotic - Abiotic Interface Between they Body and the Artificial Limb

    National Research Council Canada - National Science Library

    Church, Kenneth H

    2008-01-01

    Intraosseous transcutaneous amputation prostheses (ITAPs) may be able to overcome the problems that stem from the nonuniform distribution of pressure seen in the conventional stump-socket prosthetic replacement devices...

  15. 6th International Congres on Ectodermal Dysplasia

    DEFF Research Database (Denmark)

    Gjørup, Hans; Nyhuus, Lone; Buhl, Jytte

    2015-01-01

    was to report treatment experiences in boys with HED treated by implant-supported dental prostheses before puberty, and to evaluate the growth of jaws during the pubertal period. Material and methods. Two boys with X-linked HED, 10 yrs of age, were included. One boy was edentulous; the other one had two molars...... (55 & 36). In addition to two mandibular implants, the treatment included bone-augmentation and insertion of maxillary implants at the age of 10 yrs. Implant-supported removable prostheses were fabricated. The study material consisted of profile cephalograms, panoramic radiographs, and clinical photos...... in the pre-pubertal period might be considered as a treatment option in edentoulous individuals with HED and in individuals with HED and very few teeth (2-3)....

  16. Surgical Templates for Dental Implant Positioning; Current ...

    African Journals Online (AJOL)

    prosthodontics; however, designing an implant‑supported prosthesis with function .... template where a provisional fixed restoration bridges the implant site. Pesun and ... in single implant therapy or short‑span implant‑supported prostheses.

  17. Accuracy of dose planning for prostate radiotherapy in the presence of metallic implants evaluated by electron spin resonance dosimetry

    Energy Technology Data Exchange (ETDEWEB)

    Alves, G.G. [Departamento de Física, Faculdade de Filosofia, Ciências e Letras de Ribeirão Preto, Universidade de São Paulo, Ribeirão Preto, SP (Brazil); Kinoshita, A. [Departamento de Física, Faculdade de Filosofia, Ciências e Letras de Ribeirão Preto, Universidade de São Paulo, Ribeirão Preto, SP (Brazil); Universidade Sagrado Coração, Bauru, SP (Brazil); Oliveira, H.F. de; Guimarães, F.S.; Amaral, L.L. [Serviço de Radioterapia, Hospital das Clínicas, Faculdade de Medicina de Ribeirão Preto, Universidade de São Paulo, Ribeirão Preto, SP (Brazil); Baffa, O. [Departamento de Física, Faculdade de Filosofia, Ciências e Letras de Ribeirão Preto, Universidade de São Paulo, Ribeirão Preto, SP (Brazil)

    2015-05-26

    Radiotherapy is one of the main approaches to cure prostate cancer, and its success depends on the accuracy of dose planning. A complicating factor is the presence of a metallic prosthesis in the femur and pelvis, which is becoming more common in elderly populations. The goal of this work was to perform dose measurements to check the accuracy of radiotherapy treatment planning under these complicated conditions. To accomplish this, a scale phantom of an adult pelvic region was used with alanine dosimeters inserted in the prostate region. This phantom was irradiated according to the planned treatment under the following three conditions: with two metallic prostheses in the region of the femur head, with only one prosthesis, and without any prostheses. The combined relative standard uncertainty of dose measurement by electron spin resonance (ESR)/alanine was 5.05%, whereas the combined relative standard uncertainty of the applied dose was 3.35%, resulting in a combined relative standard uncertainty of the whole process of 6.06%. The ESR dosimetry indicated that there was no difference (P>0.05, ANOVA) in dosage between the planned dose and treatments. The results are in the range of the planned dose, within the combined relative uncertainty, demonstrating that the treatment-planning system compensates for the effects caused by the presence of femur and hip metal prostheses.

  18. Accuracy of dose planning for prostate radiotherapy in the presence of metallic implants evaluated by electron spin resonance dosimetry.

    Science.gov (United States)

    Alves, G G; Kinoshita, A; Oliveira, H F de; Guimarães, F S; Amaral, L L; Baffa, O

    2015-07-01

    Radiotherapy is one of the main approaches to cure prostate cancer, and its success depends on the accuracy of dose planning. A complicating factor is the presence of a metallic prosthesis in the femur and pelvis, which is becoming more common in elderly populations. The goal of this work was to perform dose measurements to check the accuracy of radiotherapy treatment planning under these complicated conditions. To accomplish this, a scale phantom of an adult pelvic region was used with alanine dosimeters inserted in the prostate region. This phantom was irradiated according to the planned treatment under the following three conditions: with two metallic prostheses in the region of the femur head, with only one prosthesis, and without any prostheses. The combined relative standard uncertainty of dose measurement by electron spin resonance (ESR)/alanine was 5.05%, whereas the combined relative standard uncertainty of the applied dose was 3.35%, resulting in a combined relative standard uncertainty of the whole process of 6.06%. The ESR dosimetry indicated that there was no difference (P>0.05, ANOVA) in dosage between the planned dose and treatments. The results are in the range of the planned dose, within the combined relative uncertainty, demonstrating that the treatment-planning system compensates for the effects caused by the presence of femur and hip metal prostheses.

  19. Adaptive sports ankle prosthetics. Interview by Sarah A. Curran.

    Science.gov (United States)

    Lyle, David K

    2012-09-01

    Participating in sport at all levels is gaining a dedicated following and this is also apparent in individuals with an amputation. Currently, there is a wide variety of ankle prostheses available which attempt to provide function, control, and comfort, as well as good aesthetic appeal. Participation in sport, however, increases the demands placed upon ankle prostheses. This can compromise function and performance, and constrain the opportunities of participation in various outdoor and water sports. In acknowledging this limitation and the need to develop more versatile ankle prostheses, this article introduces the evolution of a prototype ankle prosthesis referred to as "Adaptive Sports Ankle." The ankle prosthesis, which is compatible with any foot pyramid adapter, offers the same range of motion as the normal human ankle joint and is made up of components that are chemical and corrosion resistant. These design features that are specifically created to accommodate below-the-knee amputees provide an ideal prosthesis for those wishing to lead an active lifestyle and participate in aquatic (i.e. swimming, surfing, and scuba diving), snowboarding, and equestrian activities. Although it is acknowledged that there is a need to establish research on the Adaptive Sports Ankle, its introduction to the market will enhance and expand opportunities of those individuals with a lower limb amputation to lead an active and healthy lifestyle.

  20. Accuracy of dose planning for prostate radiotherapy in the presence of metallic implants evaluated by electron spin resonance dosimetry

    International Nuclear Information System (INIS)

    Alves, G.G.; Kinoshita, A.; Oliveira, H.F. de; Guimarães, F.S.; Amaral, L.L.; Baffa, O.

    2015-01-01

    Radiotherapy is one of the main approaches to cure prostate cancer, and its success depends on the accuracy of dose planning. A complicating factor is the presence of a metallic prosthesis in the femur and pelvis, which is becoming more common in elderly populations. The goal of this work was to perform dose measurements to check the accuracy of radiotherapy treatment planning under these complicated conditions. To accomplish this, a scale phantom of an adult pelvic region was used with alanine dosimeters inserted in the prostate region. This phantom was irradiated according to the planned treatment under the following three conditions: with two metallic prostheses in the region of the femur head, with only one prosthesis, and without any prostheses. The combined relative standard uncertainty of dose measurement by electron spin resonance (ESR)/alanine was 5.05%, whereas the combined relative standard uncertainty of the applied dose was 3.35%, resulting in a combined relative standard uncertainty of the whole process of 6.06%. The ESR dosimetry indicated that there was no difference (P>0.05, ANOVA) in dosage between the planned dose and treatments. The results are in the range of the planned dose, within the combined relative uncertainty, demonstrating that the treatment-planning system compensates for the effects caused by the presence of femur and hip metal prostheses