WorldWideScience

Sample records for prostate image alignment

  1. A Workflow to Improve the Alignment of Prostate Imaging with Whole-mount Histopathology.

    Science.gov (United States)

    Yamamoto, Hidekazu; Nir, Dror; Vyas, Lona; Chang, Richard T; Popert, Rick; Cahill, Declan; Challacombe, Ben; Dasgupta, Prokar; Chandra, Ashish

    2014-08-01

    Evaluation of prostate imaging tests against whole-mount histology specimens requires accurate alignment between radiologic and histologic data sets. Misalignment results in false-positive and -negative zones as assessed by imaging. We describe a workflow for three-dimensional alignment of prostate imaging data against whole-mount prostatectomy reference specimens and assess its performance against a standard workflow. Ethical approval was granted. Patients underwent motorized transrectal ultrasound (Prostate Histoscanning) to generate a three-dimensional image of the prostate before radical prostatectomy. The test workflow incorporated steps for axial alignment between imaging and histology, size adjustments following formalin fixation, and use of custom-made parallel cutters and digital caliper instruments. The control workflow comprised freehand cutting and assumed homogeneous block thicknesses at the same relative angles between pathology and imaging sections. Thirty radical prostatectomy specimens were histologically and radiologically processed, either by an alignment-optimized workflow (n = 20) or a control workflow (n = 10). The optimized workflow generated tissue blocks of heterogeneous thicknesses but with no significant drifting in the cutting plane. The control workflow resulted in significantly nonparallel blocks, accurately matching only one out of four histology blocks to their respective imaging data. The image-to-histology alignment accuracy was 20% greater in the optimized workflow (P alignment was observed in the optimized workflow. Evaluation of prostate imaging biomarkers using whole-mount histology references should include a test-to-reference spatial alignment workflow. Copyright © 2014 AUR. Published by Elsevier Inc. All rights reserved.

  2. Alignment Focus of Daily Image Guidance for Concurrent Treatment of Prostate and Pelvic Lymph Nodes

    International Nuclear Information System (INIS)

    Ferjani, Samah; Huang, Guangshun; Shang, Qingyang; Stephans, Kevin L.; Zhong, Yahua; Qi, Peng; Tendulkar, Rahul D.; Xia, Ping

    2013-01-01

    Purpose: To determine the dosimetric impact of daily imaging alignment focus on the prostate soft tissue versus the pelvic bones for the concurrent treatment of the prostate and pelvic lymph nodes (PLN) and to assess whether multileaf collimator (MLC) tracking or adaptive planning (ART) is necessary with the current clinical planning margins of 8 mm/6 mm posterior to the prostate and 5 mm to the PLN. Methods and Materials: A total of 124 kilovoltage cone-beam computed tomography (kV-CBCT) images from 6 patients were studied. For each KV-CBCT, 4 plans were retrospectively created using an isocenter shifting method with 2 different alignment focuses (prostate, PLN), an MLC shifting method, and the ART method. The selected dosimetric endpoints were compared among these plans. Results: For the isoshift contour, isoshift bone, MLC shift, and ART plans, D99 of the prostate was ≥97% of the prescription dose in 97.6%, 73.4%, 98.4%, and 96.8% of 124 fractions, respectively. Accordingly, D99 of the PLN was ≥97% of the prescription dose in 98.4%, 98.4%, 98.4%, and 100% of 124 fractions, respectively. For the rectum, D5 exceeded 105% of the planned D5 (and D5 of ART plans) in 11% (4%), 10% (2%), and 13% (5%) of 124 fractions, respectively. For the bladder, D5 exceeded 105% of the planned D5 (and D5 of ART) plans in 0% (2%), 0% (2%), and 0% (1%) of 124 fractions, respectively. Conclusion: For concurrent treatment of the prostate and PLN, with a planning margin to the prostate of 8 mm/6 mm posterior and a planning margin of 5 mm to the PLN, aligning to the prostate soft tissue can achieve adequate dose coverage to the both target volumes; aligning to the pelvic bone would result in underdosing to the prostate in one-third of fractions. With these planning margins, MLC tracking and ART methods have no dosimetric advantages

  3. Alignment focus of daily image guidance for concurrent treatment of prostate and pelvic lymph nodes.

    Science.gov (United States)

    Ferjani, Samah; Huang, Guangshun; Shang, Qingyang; Stephans, Kevin L; Zhong, Yahua; Qi, Peng; Tendulkar, Rahul D; Xia, Ping

    2013-10-01

    To determine the dosimetric impact of daily imaging alignment focus on the prostate soft tissue versus the pelvic bones for the concurrent treatment of the prostate and pelvic lymph nodes (PLN) and to assess whether multileaf collimator (MLC) tracking or adaptive planning (ART) is necessary with the current clinical planning margins of 8 mm/6 mm posterior to the prostate and 5 mm to the PLN. A total of 124 kilovoltage cone-beam computed tomography (kV-CBCT) images from 6 patients were studied. For each KV-CBCT, 4 plans were retrospectively created using an isocenter shifting method with 2 different alignment focuses (prostate, PLN), an MLC shifting method, and the ART method. The selected dosimetric endpoints were compared among these plans. For the isoshift contour, isoshift bone, MLC shift, and ART plans, D99 of the prostate was ≥97% of the prescription dose in 97.6%, 73.4%, 98.4%, and 96.8% of 124 fractions, respectively. Accordingly, D99 of the PLN was ≥97% of the prescription dose in 98.4%, 98.4%, 98.4%, and 100% of 124 fractions, respectively. For the rectum, D5 exceeded 105% of the planned D5 (and D5 of ART plans) in 11% (4%), 10% (2%), and 13% (5%) of 124 fractions, respectively. For the bladder, D5 exceeded 105% of the planned D5 (and D5 of ART) plans in 0% (2%), 0% (2%), and 0% (1%) of 124 fractions, respectively. For concurrent treatment of the prostate and PLN, with a planning margin to the prostate of 8 mm/6 mm posterior and a planning margin of 5 mm to the PLN, aligning to the prostate soft tissue can achieve adequate dose coverage to the both target volumes; aligning to the pelvic bone would result in underdosing to the prostate in one-third of fractions. With these planning margins, MLC tracking and ART methods have no dosimetric advantages. Copyright © 2013 Elsevier Inc. All rights reserved.

  4. Towards 3D ultrasound image based soft tissue tracking: a transrectal ultrasound prostate image alignment system.

    Science.gov (United States)

    Baumann, Michael; Mozer, Pierre; Daanen, Vincent; Troccaz, Jocelyne

    2007-01-01

    The emergence of real-time 3D ultrasound (US) makes it possible to consider image-based tracking of subcutaneous soft tissue targets for computer guided diagnosis and therapy. We propose a 3D transrectal US based tracking system for precise prostate biopsy sample localisation. The aim is to improve sample distribution, to enable targeting of unsampled regions for repeated biopsies, and to make post-interventional quality controls possible. Since the patient is not immobilized, since the prostate is mobile and due to the fact that probe movements are only constrained by the rectum during biopsy acquisition, the tracking system must be able to estimate rigid transformations that are beyond the capture range of common image similarity measures. We propose a fast and robust multi-resolution attribute-vector registration approach that combines global and local optimization methods to solve this problem. Global optimization is performed on a probe movement model that reduces the dimensionality of the search space and thus renders optimization efficient. The method was tested on 237 prostate volumes acquired from 14 different patients for 3D to 3D and 3D to orthogonal 2D slices registration. The 3D-3D version of the algorithm converged correctly in 96.7% of all cases in 6.5s with an accuracy of 1.41mm (r.m.s.) and 3.84mm (max). The 3D to slices method yielded a success rate of 88.9% in 2.3s with an accuracy of 1.37mm (r.m.s.) and 4.3mm (max).

  5. 2D kV orthogonal imaging with fiducial markers is more precise for daily image guided alignments than soft-tissue cone beam computed tomography for prostate radiation therapy

    Directory of Open Access Journals (Sweden)

    Peter H. Goff, MD, PhD

    2017-07-01

    Conclusions: The kV-FM–based daily IG alignment for IMRT of prostate cancer is more precise than ST-CBCT, as assessed by a physician's ability to reproducibly align images. Given the magnitude of the error introduced by inconsistency in making ST-CBCT alignments, these data support a role for daily kV imaging of FM to enhance the precision of external beam dose delivery to the prostate.

  6. A feature alignment score for online cone-beam CT-based image-guided radiotherapy for prostate cancer.

    Science.gov (United States)

    Hargrave, Catriona; Deegan, Timothy; Poulsen, Michael; Bednarz, Tomasz; Harden, Fiona; Mengersen, Kerrie

    2018-05-17

    To develop a method for scoring online cone-beam CT (CBCT)-to-planning CT image feature alignment to inform prostate image-guided radiotherapy (IGRT) decision-making. The feasibility of incorporating volume variation metric thresholds predictive of delivering planned dose into weighted functions, was investigated. Radiation therapists and radiation oncologists participated in workshops where they reviewed prostate CBCT-IGRT case examples and completed a paper-based survey of image feature matching practices. For 36 prostate cancer patients, one daily CBCT was retrospectively contoured then registered with their plan to simulate delivered dose if (a) no online setup corrections and (b) online image alignment and setup corrections, were performed. Survey results were used to select variables for inclusion in classification and regression tree (CART) and boosted regression trees (BRT) modeling of volume variation metric thresholds predictive of delivering planned dose to the prostate, proximal seminal vesicles (PSV), bladder, and rectum. Weighted functions incorporating the CART and BRT results were used to calculate a score of individual tumor and organ at risk image feature alignment (FAS TV _ OAR ). Scaled and weighted FAS TV _ OAR were then used to calculate a score of overall treatment compliance (FAS global ) for a given CBCT-planning CT registration. The FAS TV _ OAR were assessed for sensitivity, specificity, and predictive power. FAS global thresholds indicative of high, medium, or low overall treatment plan compliance were determined using coefficients from multiple linear regression analysis. Thirty-two participants completed the prostate CBCT-IGRT survey. While responses demonstrated consensus of practice for preferential ranking of planning CT and CBCT match features in the presence of deformation and rotation, variation existed in the specified thresholds for observed volume differences requiring patient repositioning or repeat bladder and bowel

  7. 'Compromise position' image alignment to accommodate independent motion of multiple clinical target volumes during radiotherapy: A high risk prostate cancer example

    International Nuclear Information System (INIS)

    Rosewall, Tara; Alasti, Hamideh; Bayley, Andrew; Yan, Jing

    2017-01-01

    Inclusion of multiple independently moving clinical target volumes (CTVs) in the irradiated volume causes an image guidance conundrum. The purpose of this research was to use high risk prostate cancer as a clinical example to evaluate a 'compromise' image alignment strategy. The daily pre-treatment orthogonal EPI for 14 consecutive patients were included in this analysis. Image matching was performed by aligning to the prostate only, the bony pelvis only and using the 'compromise' strategy. Residual CTV surrogate displacements were quantified for each of the alignment strategies. Analysis of the 388 daily fractions indicated surrogate displacements were well-correlated in all directions (r 2 = 0.95 (LR), 0.67 (AP) and 0.59 (SI). Differences between the surrogates displacements (95% range) were −0.4 to 1.8 mm (LR), −1.2 to 5.2 mm (SI) and −1.2 to 5.2 mm (AP). The distribution of the residual displacements was significantly smaller using the 'compromise' strategy, compared to the other strategies (p 0.005). The 'compromise' strategy ensured the CTV was encompassed by the PTV in all fractions, compared to 47 PTV violations when aligned to prostate only. This study demonstrated the feasibility of a compromise position image guidance strategy to accommodate simultaneous displacements of two independently moving CTVs. Application of this strategy was facilitated by correlation between the CTV displacements and resulted in no geometric excursions of the CTVs beyond standard sized PTVs. This simple image guidance strategy may also be applicable to other disease sites that concurrently irradiate multiple CTVs, such as head and neck, lung and cervix cancer.

  8. 'Compromise position' image alignment to accommodate independent motion of multiple clinical target volumes during radiotherapy: A high risk prostate cancer example.

    Science.gov (United States)

    Rosewall, Tara; Yan, Jing; Alasti, Hamideh; Cerase, Carla; Bayley, Andrew

    2017-04-01

    Inclusion of multiple independently moving clinical target volumes (CTVs) in the irradiated volume causes an image guidance conundrum. The purpose of this research was to use high risk prostate cancer as a clinical example to evaluate a 'compromise' image alignment strategy. The daily pre-treatment orthogonal EPI for 14 consecutive patients were included in this analysis. Image matching was performed by aligning to the prostate only, the bony pelvis only and using the 'compromise' strategy. Residual CTV surrogate displacements were quantified for each of the alignment strategies. Analysis of the 388 daily fractions indicated surrogate displacements were well-correlated in all directions (r 2  = 0.95 (LR), 0.67 (AP) and 0.59 (SI). Differences between the surrogates displacements (95% range) were -0.4 to 1.8 mm (LR), -1.2 to 5.2 mm (SI) and -1.2 to 5.2 mm (AP). The distribution of the residual displacements was significantly smaller using the 'compromise' strategy, compared to the other strategies (p 0.005). The 'compromise' strategy ensured the CTV was encompassed by the PTV in all fractions, compared to 47 PTV violations when aligned to prostate only. This study demonstrated the feasibility of a compromise position image guidance strategy to accommodate simultaneous displacements of two independently moving CTVs. Application of this strategy was facilitated by correlation between the CTV displacements and resulted in no geometric excursions of the CTVs beyond standard sized PTVs. This simple image guidance strategy may also be applicable to other disease sites that concurrently irradiate multiple CTVs, such as head and neck, lung and cervix cancer. © 2016 The Royal Australian and New Zealand College of Radiologists.

  9. Utilization of cone-beam CT for offline evaluation of target volume coverage during prostate image-guided radiotherapy based on bony anatomy alignment.

    Science.gov (United States)

    Paluska, Petr; Hanus, Josef; Sefrova, Jana; Rouskova, Lucie; Grepl, Jakub; Jansa, Jan; Kasaova, Linda; Hodek, Miroslav; Zouhar, Milan; Vosmik, Milan; Petera, Jiri

    2012-01-01

    To assess target volume coverage during prostate image-guided radiotherapy based on bony anatomy alignment and to assess possibility of safety margin reduction. Implementation of IGRT should influence safety margins. Utilization of cone-beam CT provides current 3D anatomic information directly in irradiation position. Such information enables reconstruction of the actual dose distribution. Seventeen prostate patients were treated with daily bony anatomy image-guidance. Cone-beam CT (CBCT) scans were acquired once a week immediately after bony anatomy alignment. After the prostate, seminal vesicles, rectum and bladder were contoured, the delivered dose distribution was reconstructed. Target dose coverage was evaluated by the proportion of the CTV encompassed by the 95% isodose. Original plans employed a 1 cm safety margin. Alternative plans assuming a smaller 7 mm margin between CTV and PTV were evaluated in the same way. Rectal and bladder volumes were compared with the initial ones. Rectal and bladder volumes irradiated with doses higher than 75 Gy, 70 Gy, 60 Gy, 50 Gy and 40 Gy were analyzed. In 12% of reconstructed plans the prostate coverage was not sufficient. The prostate underdosage was observed in 5 patients. Coverage of seminal vesicles was not satisfactory in 3% of plans. Most of the target underdosage corresponded to excessive rectal or bladder filling. Evaluation of alternative plans assuming a smaller 7 mm margin revealed 22% and 11% of plans where prostate and seminal vesicles coverage, respectively, was compromised. These were distributed over 8 and 7 patients, respectively. Sufficient dose coverage of target volumes was not achieved for all patients. Reducing of safety margin is not acceptable. Initial rectal and bladder volumes cannot be considered representative for subsequent treatment.

  10. Experimental image alignment system

    Science.gov (United States)

    Moyer, A. L.; Kowel, S. T.; Kornreich, P. G.

    1980-01-01

    A microcomputer-based instrument for image alignment with respect to a reference image is described which uses the DEFT sensor (Direct Electronic Fourier Transform) for image sensing and preprocessing. The instrument alignment algorithm which uses the two-dimensional Fourier transform as input is also described. It generates signals used to steer the stage carrying the test image into the correct orientation. This algorithm has computational advantages over algorithms which use image intensity data as input and is suitable for a microcomputer-based instrument since the two-dimensional Fourier transform is provided by the DEFT sensor.

  11. Prostate imaging. An update

    International Nuclear Information System (INIS)

    Franiel, T.; Teichgraeber, U.; Asbach, P.; Hamm, B.; Foller, S.

    2015-01-01

    New technical and clinical developments of sonography and magnetic resonance imaging include improved detection, localization and staging as well as active surveillance of prostate cancer. Multiparametric MRI can best answer these typical clinical questions. However, ultrasound elastography seems to be suitable for the detection of significant prostate cancer as well. The structured reporting system for multiparametric MRI of the prostate according to PI-RADS Version 1 led to improved and reproducible diagnosis of prostate cancer. The new PI-RADS Version 2 aims to minimize the limitations of Version 1 and make PI-RADS standardization more globally acceptable.

  12. Imaging of the prostate

    International Nuclear Information System (INIS)

    Turgut, A.

    2012-01-01

    Full text: The main role of imaging in prostatic diseases is for prostate cancer. Transrectal ultrasound (TRUS) and magnetic resonance imaging (MRI) are the most commonly used imaging tools used for the diagnosis of the diseases of the prostate gland. The main indications for TRUS is the evaluation for prostate cancer and guidance for prostate biopsy. On TRUS, the transition zone with a hypoechoic appearance can be differentiated from the peripheral zone, which appears relatively echogenic and homogenous in echotexture. Prostate cancer mainly involves the peripheral zone, though one fifth of the disease can be detected in the transition zone, which is the major site for hyperplastic changes in older men. Color Doppler ultrasound may be helpful for the differentiation of low-risk, hypovascular tumors from high-risk, hypervascular tumors, as the latter group is associated with higher Gleason tumor grades consistent with higher risk for extraprostatic spread. Nevertheless, targeted prostate biopsy solely based on high-frequency color or power Doppler imaging is not recommended, as the technique has inherent risk of missing a significant number of cancers. Although power Doppler ultrasound can enable the operator to perform more accurate sampling of the prostate by determining sites of focal hypervascularity, it has not been found to be superior to color Doppler ultrasound. It has been reported to be useful only for targeted biopsies with limited number of biopsy cores. Microbubble contrast agents may enable better visualization of prostatic microvasculature and cancerous prostate tissue. By means of contrast-enhanced ultrasound (CEUS), the number of cores may be decreased by performing targeted biopsies. Importantly, the detection of the signals reflected by the microbubbles can be enhanced by the phase inversion (pulse-inversion) technology. Prostate cancer appears as a dark zone on elastography representing limited elasticity or compressibility. By means of the

  13. Imaging and prostate cancer

    International Nuclear Information System (INIS)

    Schwartz, Lawrence H.

    1996-01-01

    The use of imaging in evaluating patients with prostate cancer is highly dependent upon the purpose of the evaluation. Ultrasound, Computed Tomography, Magnetic Resonance Imaging, TC-99m Bone Scanning, and Positron Emission Tomography may all be utilized for imaging in prostate cancer. The utility of each of these modalities depends upon the intended purpose: for instance, screening, staging, or evaluating for progression of disease in patients with prostate cancer. Transrectal ultrasound is performed by placing a 5MHz to 7.5 MHz transducer in the rectum and imaging the prostate in the coronal and sagittal planes. Prostate cancer generally appears as an area of diminished echogenocity in the peripheral zone of the prostate gland. However, up to 24% of prostate cancers are isoechoic and cannot be well distinguished from the remainder of the peripheral zone. In addition, the incidence of malignancy in a lesion judged to be suspicious on ultrasound is between 20% and 25%. Therefore, while ultrasound is the least expensive of the three cross sectional imaging modalities, its relatively low specificity precludes it from being used as a screening examination. Investigators have also looked at the ability of ultrasound to evaluate the presence and extent of extracapsular spread of prostate cancer. The RDOG (Radiology Diagnostic Oncology Group) multi-institutional cooperative trial reported a disappointing overall accuracy of ultrasound of 58% for staging prostate cancer. The accuracy was somewhat higher 63%, for patients with advanced disease. The other cross-sectional imaging modalities available for imaging the prostate include Computed Tomography and Magnetic Resonance Imaging. Computed Tomography is useful as an 'anatomic' imaging technique to detect lymph node enlargement. It is not sensitive in detecting microscopic nodal involvement with tumor, or tumor in non-enlarged pelvic lymph nodes. The primary prostate neoplasm is generally the same attenuation as the normal

  14. Automatic alignment of radionuclide images

    International Nuclear Information System (INIS)

    Barber, D.C.

    1982-01-01

    The variability of the position, dimensions and orientation of a radionuclide image within the field of view of a gamma camera hampers attempts to analyse the image numerically. This paper describes a method of using a set of training images of a particular type, in this case right lateral brain images, to define the likely variations in the position, dimensions and orientation for that type of image and to provide alignment data for a program that automatically aligns new images of the specified type to a standard position, size and orientation. Examples are given of the use of this method on three types of radionuclide image. (author)

  15. MR imaging of the prostate

    International Nuclear Information System (INIS)

    Asbach, P.; Haas, M.; Hamm, B.

    2015-01-01

    Prostate cancer is the most common form of cancer in men in Germany; however, there is a distinct difference between incidence and mortality. The detection of prostate cancer is based on clinical and laboratory testing using serum prostate-specific antigen (PSA) levels and transrectal ultrasound with randomized biopsy. Multiparametric MR imaging of the prostate can provide valuable diagnostic information for detection of prostate cancer, especially after negative results of a biopsy prior to repeat biopsy. In addition the use of MR ultrasound fusion-guided biopsy has gained in diagnostic importance and has increased the prostate cancer detection rate. The prostate imaging reporting and data system (PI-RADS) classification has standardized the reporting of prostate MRI which has positively influenced the acceptance by urologists. (orig.) [de

  16. Alignment of diabetic feet images

    NARCIS (Netherlands)

    Klein, Almar; van der Heijden, Ferdinand; Slump, Cornelis H.; Uyl, M.J.; Philips, W.

    2007-01-01

    This paper addresses the problem of aligning the images of feet taken at different instances in time. We propose to use SIFT keypoints to find the geometric deformation between two photo’s. We then have a set of landmarks for each image. By finding the corresponding landmarks (i.e. matching the

  17. Initial experience with megavoltage (MV) CT guidance for daily prostate alignments

    International Nuclear Information System (INIS)

    Langen, Katja M.; Zhang Yashan; Andrews, Rhonda D.; Hurley, Monica E.; Meeks, Sanford L.; Poole, Darrell O.; Willoughby, Twyla R.; Kupelian, Patrick A.

    2005-01-01

    Purpose: The on-board megavoltage (MV) computed tomography (CT) capabilities of a TomoTherapy Hi*ART unit were used to obtain daily MVCT images of prostate cancer patients. For patient alignment the daily MVCT image needs to be registered with the planning CT image to calculate couch shifts. Three manual techniques of registering the MVCT images with the planning kilovoltage (kV) CT images were evaluated. The techniques are based on visual alignment of (1) fiducial prostate markers (2) CT anatomy, and (3) kVCT contours. Methods and Materials: One hundred and twelve alignments from 3 patients were available for analysis. The radiation therapists visually registered the MVCT images with the planning kVCT images based on fiducial markers for actual patient alignment. Retrospectively, the therapists registered each image set using anatomy and contour-based techniques. In addition to the therapists, a physician retrospectively registered each image set based on each of the three techniques. For each MVCT to kVCT image pair a reference alignment was computed from the center-of-mass (COM) of the three fiducial markers. All registration results were compared with these reference alignments. The physician's image registrations were compared with the radiation therapists' registrations to assess the user variability of the different techniques. Results: The marker-based registration results agree best with the reference alignments, while the contour-based registrations show the least degree of agreement. Using anatomy and contour-based registrations, the radiation therapist's alignments differed by ≥ 3 mm from the reference alignments in 24%, 33%, and 3% and 55%, 48%, and 21% of all registrations in the anterior-posterior, superior-inferior, and lateral directions, respectively. The respective values for the marker-based alignments were 3%, 6%, and 3%. The physician's registrations showed the same general trend. The marker-based registrations showed the least amount of

  18. Granulomatous prostatitis: a pitfall in MR imaging of prostatic carcinoma

    Energy Technology Data Exchange (ETDEWEB)

    Gevenois, P.A. [Dept. of Radiology, Cliniques Univ. de Bruxelles, Hopital Erasme (Belgium); Stallenberg, B. [Dept. of Radiology, Cliniques Univ. de Bruxelles, Hopital Erasme (Belgium); Sintzoff, S.A. [Dept. of Radiology, Cliniques Univ. de Bruxelles, Hopital Erasme (Belgium); Salmon, I. [Dept. of Pathology, Cliniques Univ. de Bruxelles, Hopital Erasme (Belgium); Regemorter, G. van [Dept. of Urology, Cliniques Univ. de Bruxelles, Hopital Erasme (Belgium); Struyven, J. [Dept. of Radiology, Cliniques Univ. de Bruxelles, Hopital Erasme (Belgium)

    1992-08-01

    Granulomatous prostatitis is an uncommon disease that can mimic prostatic carcinoma on both digital rectal examination and transrectal ultrasound. Four patients who underwent magnetic resonance imaging of the prostate had a histological diagnosis of granulomatous prostatitis; three of them had recent urinary tract infections. The other patient had an associated midline prostatic cyst and a focus of malignancy. T1- and T2-weighted spin-echo images were obtained in all cases. Peripheral zone lesions of decreased signal intensity, suggestive of carcinoma, were found in all four patients on T2-weighted images. Granulomatous prostatitis should be considered in the differential diagnosis of low signal intensity areas with prostatic magnetic resonance imaging. (orig.)

  19. Magnetic resonance imaging of the prostate

    DEFF Research Database (Denmark)

    Iversen, P; Kjaer, L; Thomsen, C

    1988-01-01

    Magnetic resonance imaging offers new possibilities in investigation of the prostate gland. Current results of imaging and tissue discrimination in the evaluation of prostatic disease are reviewed. Magnetic resonance imaging may be useful in the staging of carcinoma of the prostate....

  20. Magnetic resonance imaging of the prostate

    DEFF Research Database (Denmark)

    Iversen, P; Kjaer, L; Thomsen, C

    1987-01-01

    Magnetic resonance imaging offers new possibilities in the investigation of the prostate. The current results of imaging and tissue discrimination in the evaluation of prostatic disease are reviewed. Magnetic resonance imaging may be of value in the staging of carcinoma of the prostate....

  1. Prostate resonance imaging: morphology and metabolism

    International Nuclear Information System (INIS)

    Ocantos, Jorge A.; Pietrani, Marcelo A.; Paganini, Lisandro

    2007-01-01

    The cancer of prostate is the most frequent neoplasms and the third cause of death in men, although the average of survival of patients it improved, the cancer of prostate is an important problem in health. The majority of these tumors are of slow growth and the early detection allows high probabilities of definitive treatment. The neoplasms of prostate detected at present are smaller than the detected ones 20 years ago behind, nevertheless exist big differences in the aggressiveness of these tumors. The images are very important in the management of prostate cancer, and the magnetic resonance imaging of the prostate is a new tool in the evaluation of prostate cancer [es

  2. Image guided prostate cancer treatments

    Energy Technology Data Exchange (ETDEWEB)

    Bard, Robert L. [Bard Cancer Center, Biofoundation for Angiogenesis Research and Development, New York, NY (United States); Fuetterer, Jurgen J. [Radboud Univ. Nijmegen, Medical Centre (Netherlands). Dept. of Radiology; Sperling, Dan (ed.) [Sperling Prostate Center, Alpha 3TMRI, New York, NY (United States)

    2014-07-01

    Systematic overview of the application of ultrasound and MRI in the diagnosis and treatment of diseases of the lower urinary tract. Detailed information on image-guided therapies, including focused ultrasound, photodynamic therapy, and microwave and laser ablation. Numerous high-quality illustrations based on high-end equipment. Represents the state of the art in Non Invasive Imaging and Minimally Invasive Ablation Treatment (MIAT). Image-Guided Prostate Cancer Treatments is a comprehensive reference and practical guide on the technology and application of ultrasound and MRI in the male pelvis, with special attention to the prostate. The book is organized into three main sections, the first of which is devoted to general aspects of imaging and image-guided treatments. The second section provides a systematic overview of the application of ultrasound and MRI to the diagnosis and treatment of diseases of the lower urinary tract. Performance of the ultrasound and MRI studies is explained, and the normal and abnormal pathological anatomy is reviewed. Correlation with the ultrasound in the same plane is provided to assist in understanding the MRI sequences. Biopsy and interventional procedures, ultrasound-MRI fusion techniques, and image-guided therapies, including focused ultrasound, photodynamic therapy, microwave and laser ablation, are all fully covered. The third section focuses on securing treatment effectiveness and the use of follow-up imaging to ensure therapeutic success and detect tumor recurrence at an early stage, which is vital given that prompt focal treatment of recurrence is very successful. Here, particular attention is paid to the role of Doppler ultrasound and DCE-MRI technologies. This book, containing a wealth of high-quality illustrations based on high-end equipment, will acquaint beginners with the basics of prostate ultrasound and MRI, while more advanced practitioners will learn new skills, means of avoiding pitfalls, and ways of effectively

  3. MR imaging of prostate cancer

    International Nuclear Information System (INIS)

    Heuck, A.; Scheidler, J.; Sommer, B.; Graser, A.; Mueller-Lisse, U.G.; Massmann, J.

    2003-01-01

    Accurate diagnosis and staging of prostate cancer (PC) is developing into an important health care issue in light of the high incidence of PC and the improvements in stage-adapted therapy. The purpose of this paper is to provide an overview on the current role of MR imaging and MR spectroscopy in the diagnosis and staging of PC.Material and methods Pertinent literature was searched and evaluated to collect information on current clinical indications, study techniques, diagnostic value, and limitations of magnetic resonance imaging and spectroscopy. Major indications for MR imaging of patients with supected PC are to define tumor location before biopsy when clinical or TRUS findings are inconclusive, and to provide accurate staging of histologically proven PC to ascertain effective therapy. Current MR imaging techniques for the evaluation of PC include multiplanar high-resolution T2-weighted FSE and T1-weighted SE sequences using combined endorectal and phased-array coils. Using these techniques, the reported accuracy of MR imaging for the diagnosis of extracapsular tumor extension ranges between 82 and 88% with sensitivities between 80 and 95%, and specificities between 82 and 93%. Typical MR findings of PC in different stages of disease, as well as diagnostic problems, such as chronic prostatitis, biopsy-related hemorrhage and therapy-related changes of prostatic tissue are discussed. In addition, the current perspectives and limitations of MR spectroscopy in PC are summarized. Current MR imaging techniques provide important diagnostic information in the pretherapeutic workup of PC including a high staging accuracy, and is superior to TRUS. (orig.) [de

  4. Multidisciplinary Functional MR Imaging for Prostate Cancer

    International Nuclear Information System (INIS)

    Kim, Jeong Kon; Jang, Yun Jin; Cho, Gyung Goo

    2009-01-01

    Various functional magnetic resonance (MR) imaging techniques are used for evaluating prostate cancer including diffusion-weighted imaging, dynamic contrast- enhanced MR imaging, and MR spectroscopy. These techniques provide unique information that is helpful to differentiate prostate cancer from non-cancerous tissue and have been proven to improve the diagnostic performance of MRI not only for cancer detection, but also for staging, post-treatment monitoring, and guiding prostate biopsies. However, each functional MR imaging technique also has inherent challenges. Therefore, in order to make accurate diagnoses, it is important to comprehensively understand their advantages and limitations, histologic background related with image findings, and their clinical relevance for evaluating prostate cancer. This article will review the basic principles and clinical significance of functional MR imaging for evaluating prostate cancer

  5. Stokes polarimetry imaging of dog prostate tissue

    Science.gov (United States)

    Kim, Jihoon; Johnston, William K., III; Walsh, Joseph T., Jr.

    2010-02-01

    Prostate cancer is the second leading cause of death in the United States in 2009. Radical prostatectomy (complete removal of the prostate) is the most common treatment for prostate cancer, however, differentiating prostate tissue from adjacent bladder, nerves, and muscle is difficult. Improved visualization could improve oncologic outcomes and decrease damage to adjacent nerves and muscle important for preservation of potency and continence. A novel Stokes polarimetry imaging (SPI) system was developed and evaluated using a dog prostate specimen in order to examine the feasibility of the system to differentiate prostate from bladder. The degree of linear polarization (DOLP) image maps from linearly polarized light illumination at different visible wavelengths (475, 510, and 650 nm) were constructed. The SPI system used the polarization property of the prostate tissue. The DOLP images allowed advanced differentiation by distinguishing glandular tissue of prostate from the muscular-stromal tissue in the bladder. The DOLP image at 650 nm effectively differentiated prostate and bladder by strong DOLP in bladder. SPI system has the potential to improve surgical outcomes in open or robotic-assisted laparoscopic removal of the prostate. Further in vivo testing is warranted.

  6. Transrectal ultrasound imaging and prostate cancer

    NARCIS (Netherlands)

    Goossen, Tjerk; Wijkstra, Hessel

    2003-01-01

    Prostate cancer is one of the most important causes of death from cancer in men. Ultrasound imaging is frequently used in the diagnosis of prostate cancer. This paper presents an overview of currently available ultrasound imaging techniques. The underlying principles and methods are discussed

  7. Image Alignment by Piecewise Planar Region Matching

    NARCIS (Netherlands)

    Lou, Z.; Gevers, T.

    2014-01-01

    Robust image registration is a challenging problem, especially when dealing with severe changes in illumination and viewpoint. Previous methods assume a global geometric model (e.g., homography) and, hence, are only able to align images under predefined constraints (e.g., planar scenes and

  8. Unsupervised image matching based on manifold alignment.

    Science.gov (United States)

    Pei, Yuru; Huang, Fengchun; Shi, Fuhao; Zha, Hongbin

    2012-08-01

    This paper challenges the issue of automatic matching between two image sets with similar intrinsic structures and different appearances, especially when there is no prior correspondence. An unsupervised manifold alignment framework is proposed to establish correspondence between data sets by a mapping function in the mutual embedding space. We introduce a local similarity metric based on parameterized distance curves to represent the connection of one point with the rest of the manifold. A small set of valid feature pairs can be found without manual interactions by matching the distance curve of one manifold with the curve cluster of the other manifold. To avoid potential confusions in image matching, we propose an extended affine transformation to solve the nonrigid alignment in the embedding space. The comparatively tight alignments and the structure preservation can be obtained simultaneously. The point pairs with the minimum distance after alignment are viewed as the matchings. We apply manifold alignment to image set matching problems. The correspondence between image sets of different poses, illuminations, and identities can be established effectively by our approach.

  9. Image correlation method for DNA sequence alignment.

    Science.gov (United States)

    Curilem Saldías, Millaray; Villarroel Sassarini, Felipe; Muñoz Poblete, Carlos; Vargas Vásquez, Asticio; Maureira Butler, Iván

    2012-01-01

    The complexity of searches and the volume of genomic data make sequence alignment one of bioinformatics most active research areas. New alignment approaches have incorporated digital signal processing techniques. Among these, correlation methods are highly sensitive. This paper proposes a novel sequence alignment method based on 2-dimensional images, where each nucleic acid base is represented as a fixed gray intensity pixel. Query and known database sequences are coded to their pixel representation and sequence alignment is handled as object recognition in a scene problem. Query and database become object and scene, respectively. An image correlation process is carried out in order to search for the best match between them. Given that this procedure can be implemented in an optical correlator, the correlation could eventually be accomplished at light speed. This paper shows an initial research stage where results were "digitally" obtained by simulating an optical correlation of DNA sequences represented as images. A total of 303 queries (variable lengths from 50 to 4500 base pairs) and 100 scenes represented by 100 x 100 images each (in total, one million base pair database) were considered for the image correlation analysis. The results showed that correlations reached very high sensitivity (99.01%), specificity (98.99%) and outperformed BLAST when mutation numbers increased. However, digital correlation processes were hundred times slower than BLAST. We are currently starting an initiative to evaluate the correlation speed process of a real experimental optical correlator. By doing this, we expect to fully exploit optical correlation light properties. As the optical correlator works jointly with the computer, digital algorithms should also be optimized. The results presented in this paper are encouraging and support the study of image correlation methods on sequence alignment.

  10. Transurethral light delivery for prostate photoacoustic imaging

    OpenAIRE

    Lediju Bell, Muyinatu A.; Guo, Xiaoyu; Song, Danny Y.; Boctor, Emad M.

    2015-01-01

    Photoacoustic imaging has broad clinical potential to enhance prostate cancer detection and treatment, yet it is challenged by the lack of minimally invasive, deeply penetrating light delivery methods that provide sufficient visualization of targets (e.g., tumors, contrast agents, brachytherapy seeds). We constructed a side-firing fiber prototype for transurethral photoacoustic imaging of prostates with a dual-array (linear and curvilinear) transrectal ultrasound probe. A method to calculate ...

  11. Image Alignment for Multiple Camera High Dynamic Range Microscopy

    OpenAIRE

    Eastwood, Brian S.; Childs, Elisabeth C.

    2012-01-01

    This paper investigates the problem of image alignment for multiple camera high dynamic range (HDR) imaging. HDR imaging combines information from images taken with different exposure settings. Combining information from multiple cameras requires an alignment process that is robust to the intensity differences in the images. HDR applications that use a limited number of component images require an alignment technique that is robust to large exposure differences. We evaluate the suitability fo...

  12. Multiparametric MR imaging in diagnosis of chronic prostatitis and its differentiation from prostate cancer

    Directory of Open Access Journals (Sweden)

    Vivek Kumar Sah

    2015-03-01

    Full Text Available Chronic prostatitis is a heterogeneous condition with high prevalence rate. Chronic prostatitis has overlap in clinical presentation with other prostate disorders and is one of the causes of high serum prostate specific antigen (PSA level. Chronic prostatitis, unlike acute prostatitis, is difficult to diagnose reliably and accurately on the clinical grounds alone. Not only this, it is also challenging to differentiate chronic prostatitis from prostate cancer with imaging modalities like TRUS and conventional MR Imaging, as the findings can mimic those of prostate cancer. Even biopsy doesn't play promising role in the diagnosis of chronic prostatitis as it has limited sensitivity and specificity. As a result of this, chronic prostatitis may be misdiagnosed as a malignant condition and end up in aggressive surgical management resulting in increased morbidity. This warrants the need of reliable diagnostic tool which has ability not only to diagnose it reliably but also to differentiate it from the prostate cancer. Recently, it is suggested that multiparametric MR Imaging of the prostate could improve the diagnostic accuracy of the prostate cancer. This review is based on the critically published literature and aims to provide an overview of multiparamateric MRI techniques in the diagnosis of chronic prostatitis and its differentiation from prostate cancer.

  13. Image Alignment for Multiple Camera High Dynamic Range Microscopy.

    Science.gov (United States)

    Eastwood, Brian S; Childs, Elisabeth C

    2012-01-09

    This paper investigates the problem of image alignment for multiple camera high dynamic range (HDR) imaging. HDR imaging combines information from images taken with different exposure settings. Combining information from multiple cameras requires an alignment process that is robust to the intensity differences in the images. HDR applications that use a limited number of component images require an alignment technique that is robust to large exposure differences. We evaluate the suitability for HDR alignment of three exposure-robust techniques. We conclude that image alignment based on matching feature descriptors extracted from radiant power images from calibrated cameras yields the most accurate and robust solution. We demonstrate the use of this alignment technique in a high dynamic range video microscope that enables live specimen imaging with a greater level of detail than can be captured with a single camera.

  14. Online updating of context-aware landmark detectors for prostate localization in daily treatment CT images

    Energy Technology Data Exchange (ETDEWEB)

    Dai, Xiubin [College of Geographic and Biologic Information, Nanjing University of Posts and Telecommunications, Nanjing, Jiangsu 210015, China and IDEA Lab, Department of Radiology and BRIC, University of North Carolina at Chapel Hill, 130 Mason Farm Road, Chapel Hill, North Carolina 27510 (United States); Gao, Yaozong [IDEA Lab, Department of Radiology and BRIC, University of North Carolina at Chapel Hill, 130 Mason Farm Road, Chapel Hill, North Carolina 27510 (United States); Shen, Dinggang, E-mail: dgshen@med.unc.edu [IDEA Lab, Department of Radiology and BRIC, University of North Carolina at Chapel Hill, 130 Mason Farm Road, Chapel Hill, North Carolina 27510 and Department of Brain and Cognitive Engineering, Korea University, Seoul (Korea, Republic of)

    2015-05-15

    Purpose: In image guided radiation therapy, it is crucial to fast and accurately localize the prostate in the daily treatment images. To this end, the authors propose an online update scheme for landmark-guided prostate segmentation, which can fully exploit valuable patient-specific information contained in the previous treatment images and can achieve improved performance in landmark detection and prostate segmentation. Methods: To localize the prostate in the daily treatment images, the authors first automatically detect six anatomical landmarks on the prostate boundary by adopting a context-aware landmark detection method. Specifically, in this method, a two-layer regression forest is trained as a detector for each target landmark. Once all the newly detected landmarks from new treatment images are reviewed or adjusted (if necessary) by clinicians, they are further included into the training pool as new patient-specific information to update all the two-layer regression forests for the next treatment day. As more and more treatment images of the current patient are acquired, the two-layer regression forests can be continually updated by incorporating the patient-specific information into the training procedure. After all target landmarks are detected, a multiatlas random sample consensus (multiatlas RANSAC) method is used to segment the entire prostate by fusing multiple previously segmented prostates of the current patient after they are aligned to the current treatment image. Subsequently, the segmented prostate of the current treatment image is again reviewed (or even adjusted if needed) by clinicians before including it as a new shape example into the prostate shape dataset for helping localize the entire prostate in the next treatment image. Results: The experimental results on 330 images of 24 patients show the effectiveness of the authors’ proposed online update scheme in improving the accuracies of both landmark detection and prostate segmentation

  15. Online updating of context-aware landmark detectors for prostate localization in daily treatment CT images

    International Nuclear Information System (INIS)

    Dai, Xiubin; Gao, Yaozong; Shen, Dinggang

    2015-01-01

    Purpose: In image guided radiation therapy, it is crucial to fast and accurately localize the prostate in the daily treatment images. To this end, the authors propose an online update scheme for landmark-guided prostate segmentation, which can fully exploit valuable patient-specific information contained in the previous treatment images and can achieve improved performance in landmark detection and prostate segmentation. Methods: To localize the prostate in the daily treatment images, the authors first automatically detect six anatomical landmarks on the prostate boundary by adopting a context-aware landmark detection method. Specifically, in this method, a two-layer regression forest is trained as a detector for each target landmark. Once all the newly detected landmarks from new treatment images are reviewed or adjusted (if necessary) by clinicians, they are further included into the training pool as new patient-specific information to update all the two-layer regression forests for the next treatment day. As more and more treatment images of the current patient are acquired, the two-layer regression forests can be continually updated by incorporating the patient-specific information into the training procedure. After all target landmarks are detected, a multiatlas random sample consensus (multiatlas RANSAC) method is used to segment the entire prostate by fusing multiple previously segmented prostates of the current patient after they are aligned to the current treatment image. Subsequently, the segmented prostate of the current treatment image is again reviewed (or even adjusted if needed) by clinicians before including it as a new shape example into the prostate shape dataset for helping localize the entire prostate in the next treatment image. Results: The experimental results on 330 images of 24 patients show the effectiveness of the authors’ proposed online update scheme in improving the accuracies of both landmark detection and prostate segmentation

  16. Dual-Modality PET/Ultrasound imaging of the Prostate

    Energy Technology Data Exchange (ETDEWEB)

    Huber, Jennifer S.; Moses, William W.; Pouliot, Jean; Hsu, I.C.

    2005-11-11

    Functional imaging with positron emission tomography (PET)will detect malignant tumors in the prostate and/or prostate bed, as well as possibly help determine tumor ''aggressiveness''. However, the relative uptake in a prostate tumor can be so great that few other anatomical landmarks are visible in a PET image. Ultrasound imaging with a transrectal probe provides anatomical detail in the prostate region that can be co-registered with the sensitive functional information from the PET imaging. Imaging the prostate with both PET and transrectal ultrasound (TRUS) will help determine the location of any cancer within the prostate region. This dual-modality imaging should help provide better detection and treatment of prostate cancer. LBNL has built a high performance positron emission tomograph optimized to image the prostate.Compared to a standard whole-body PET camera, our prostate-optimized PET camera has the same sensitivity and resolution, less backgrounds and lower cost. We plan to develop the hardware and software tools needed for a validated dual PET/TRUS prostate imaging system. We also plan to develop dual prostate imaging with PET and external transabdominal ultrasound, in case the TRUS system is too uncomfortable for some patients. We present the design and intended clinical uses for these dual imaging systems.

  17. Dual-Modality PET/Ultrasound imaging of the Prostate

    International Nuclear Information System (INIS)

    Huber, Jennifer S.; Moses, William W.; Pouliot, Jean; Hsu, I.C.

    2005-01-01

    Functional imaging with positron emission tomography (PET)will detect malignant tumors in the prostate and/or prostate bed, as well as possibly help determine tumor ''aggressiveness''. However, the relative uptake in a prostate tumor can be so great that few other anatomical landmarks are visible in a PET image. Ultrasound imaging with a transrectal probe provides anatomical detail in the prostate region that can be co-registered with the sensitive functional information from the PET imaging. Imaging the prostate with both PET and transrectal ultrasound (TRUS) will help determine the location of any cancer within the prostate region. This dual-modality imaging should help provide better detection and treatment of prostate cancer. LBNL has built a high performance positron emission tomograph optimized to image the prostate.Compared to a standard whole-body PET camera, our prostate-optimized PET camera has the same sensitivity and resolution, less backgrounds and lower cost. We plan to develop the hardware and software tools needed for a validated dual PET/TRUS prostate imaging system. We also plan to develop dual prostate imaging with PET and external transabdominal ultrasound, in case the TRUS system is too uncomfortable for some patients. We present the design and intended clinical uses for these dual imaging systems

  18. PET/CT Imaging and Radioimmunotherapy of Prostate Cancer

    DEFF Research Database (Denmark)

    Bouchelouche, Kirsten; Tagawa, Scott T; Goldsmith, Stanley J

    2011-01-01

    disease (ideal for antigen access and antibody delivery). Furthermore, prostate cancer is also radiation sensitive. Prostate-specific membrane antigen is expressed by virtually all prostate cancers, and represents an attractive target for RIT. Antiprostate-specific membrane antigen RIT demonstrates......Prostate cancer is a common cancer in men and continues to be a major health problem. Imaging plays an important role in the clinical management of patients with prostate cancer. An important goal for prostate cancer imaging is more accurate disease characterization through the synthesis...... of anatomic, functional, and molecular imaging information. Positron emission tomography (PET)/computed tomography (CT) in oncology is emerging as an important imaging tool. The most common radiotracer for PET/CT in oncology, (18)F-fluorodeoxyglucose (FDG), is not very useful in the imaging of prostate cancer...

  19. Impact of inter- and intrafraction deviations and residual set-up errors on PTV margins. Different alignment techniques in 3D conformal prostate cancer radiotherapy

    International Nuclear Information System (INIS)

    Langsenlehner, T.; Doeller, C.; Winkler, P.; Kapp, K.S.; Galle, G.

    2013-01-01

    The aim of this work was to analyze interfraction and intrafraction deviations and residual set-up errors (RSE) after online repositioning to determine PTV margins for 3 different alignment techniques in prostate cancer radiotherapy. The present prospective study included 44 prostate cancer patients with implanted fiducials treated with three-dimensional (3D) conformal radiotherapy. Daily localization was based on skin marks followed by marker detection using kilovoltage (kV) imaging and subsequent patient repositioning. Additionally, in-treatment megavoltage (MV) images were obtained for each treatment field. In an off-line analysis of 7,273 images, interfraction prostate motion, RSE after marker-based prostate localization, prostate position during each treatment session, and the effect of treatment time on intrafraction deviations were analyzed to evaluate PTV margins. Margins accounting for interfraction deviation, RSE and intrafraction motion were 14.1, 12.9, and 15.1 mm in anterior-posterior (AP), superior-inferior (SI), and left-right (LR) direction for skin mark alignment and 9.6, 8.7, and 2.6 mm for bony structure alignment, respectively. Alignment to implanted markers required margins of 4.6, 2.8, and 2.5 mm. As margins to account for intrafraction motion increased with treatment prolongation PTV margins could be reduced to 3.9, 2.6, and 2.4 mm if treatment time was ≤ 4 min. With daily online correction and repositioning based on implanted fiducials, a significant reduction of PTV margins can be achieved. The use of an optimized workflow with faster treatment techniques such as volumetric modulated arc techniques (VMAT) could allow for a further decrease. (orig.)

  20. Dosimetric effects of the prone and supine positions on image guided localized prostate cancer radiotherapy

    International Nuclear Information System (INIS)

    Liu Bei; Lerma, Fritz A.; Patel, Shilpen; Amin, Pradip; Feng Yuanming; Yi, B.-Y.; Yu, Cedric

    2008-01-01

    Purpose: To compare target coverage and doses to rectum and bladder in IMRT of localized prostate cancer in the supine versus prone position, with the inclusion of image guidance. Materials and methods: Twenty patients with early stage localized prostate carcinoma who received external beam radiotherapy in the supine and prone positions underwent approximately 10 serial CT examinations in their respective treatment position in non-consecutive days, except for one patient who was treated prone but serially imaged supine. The prostate, bladder and rectum were contoured on all CT scans. A PTV was generated on the first scan of each patient's CT series by expanding the prostate with a 5 mm margin and an IMRT plan was created. The resultant IMRT plan was then applied to that patient's remaining serial CT scans by aligning the initial CT image set with the subsequent serial CT image sets using (1) skin marks, (2) bony anatomy and (3) center of mass of the prostate. The dosimetric results from these three alignments were compared between the supine and prone groups. To account for the uncertainties associated with prostate delineation and intra-fractional geometric changes, a fictional 'daily PTV' was generated by expanding the prostate with a 3 mm margin on each serial CT scan. Thus, a more realistic target coverage index, V95, was quantified as the fraction of the daily PTV receiving at least 95% of the prescription dose. Dose-volume measures of the organs at risk were also compared. The fraction of the daily PTV contained by the initial PTV after each alignment method was quantified on each patient's serial CT scan, and is defined as PTV overlap index. Results: As expected, alignment based on skin marks yielded unacceptable dose coverage for both groups of patients. Under bony alignment, the target coverage index, V95, was 97.3% and 93.6% for prone and supine patients (p < 0.0001), respectively. The mean PTV overlap indices were 90.7% and 84.7% for prone and supine

  1. Method and apparatus for improving the alignment of radiographic images

    International Nuclear Information System (INIS)

    Schuller, P.D.; Hatcher, D.C.; Caelli, T.M.; Eggert, F.M.; Yuzyk, J.

    1991-01-01

    This invention relates generally to the field of radiology, and has to do particularly with a method and apparatus for improving the alignment of radiographic images taken at different times of the same tissue structure, so that the images can be sequentially shown in aligned condition, whereby changes in the structure can be noted. (author). 10 figs

  2. Interactive, multi-modality image registrations for combined MRI/MRSI-planned HDR prostate brachytherapy

    Directory of Open Access Journals (Sweden)

    Galen Reed

    2011-03-01

    Full Text Available Purpose: This study presents the steps and criteria involved in the series of image registrations used clinically during the planning and dose delivery of focal high dose-rate (HDR brachytherapy of the prostate. Material and methods: Three imaging modalities – Magnetic Resonance Imaging (MRI, Magnetic Resonance Spectroscopic Imaging (MRSI, and Computed Tomography (CT – were used at different steps during the process. MRSI is used for identification of dominant intraprosatic lesions (DIL. A series of rigid and nonrigid transformations were applied to the data to correct for endorectal-coil-induced deformations and for alignment with the planning CT. Mutual information was calculated as a morphing metric. An inverse planning optimization algorithm was applied to boost dose to the DIL while providing protection to the urethra, penile bulb, rectum, and bladder. Six prostate cancer patients were treated using this protocol. Results: The morphing algorithm successfully modeled the probe-induced prostatic distortion. Mutual information calculated between the morphed images and images acquired without the endorectal probe showed a significant (p = 0.0071 increase to that calculated between the unmorphed images and images acquired without the endorectal probe. Both mutual information and visual inspection serve as effective diagnostics of image morphing. The entire procedure adds less than thirty minutes to the treatment planning. Conclusion: This work demonstrates the utility of image transformations and registrations to HDR brachytherapy of prostate cancer.

  3. Diffusion weighted imaging in prostate cancer

    Energy Technology Data Exchange (ETDEWEB)

    Tan, Cher Heng [The University of Texas, M D Anderson Cancer Center, Department of Diagnostic Radiology, Division of Diagnostic Imaging, Houston, TX (United States); Tan Tock Seng Hospital, Department of Diagnostic Radiology, Singapore (Singapore); Wang, Jihong [The University of Texas, M D Anderson Cancer Center, Department of Imaging Physics, Division of Diagnostic Imaging, Houston, TX (United States); Kundra, Vikas [The University of Texas, M D Anderson Cancer Center, Department of Diagnostic Radiology, Division of Diagnostic Imaging, Houston, TX (United States); The University of Texas, M D Anderson Cancer Center, Department of Experimental Diagnostic Imaging, Division of Diagnostic Imaging, Houston, TX (United States)

    2011-03-15

    Diffusion-weighted imaging has generated substantial interest in the hope that it can be developed into a robust technique to improve the accuracy of MRI for the evaluation of prostate cancer. This technique has the advantages of short acquisition times, no need for intravenous administration of contrast medium, and the ability to study diffusion of water molecules that indirectly reflects tissue cellularity. In this article, we review the existing literature on the utility of DWI in tumour detection, localisation, treatment response, limitations of the technique, how it compares with other imaging techniques, technical considerations and future directions. (orig.)

  4. Influence of volumes of prostate, rectum, and bladder on treatment planning CT on interfraction prostate shifts during ultrasound image-guided IMRT

    International Nuclear Information System (INIS)

    Reddy, Nandanuri M. S.; Nori, Dattatreyudu; Sartin, William; Maiorano, Samuel; Modena, Jennifer; Mazur, Andrej; Osian, Adrian; Sood, Brijmohan; Ravi, Akkamma; Sampath, Seshadri; Lange, Christopher S.

    2009-01-01

    Purpose: The purpose of this study was to analyze the relationship between prostate, bladder, and rectum volumes on treatment planning CT day and prostate shifts in the XYZ directions on treatment days. Methods: Prostate, seminal vesicles, bladder, and rectum were contoured on CT images obtained in supine position. Intensity modulated radiation therapy plans was prepared. Contours were exported to BAT-ultrasound imaging system. Patients were positioned on the couch using skin marks. An ultrasound probe was used to obtain ultrasound images of prostate, bladder, and rectum, which were aligned with CT images. Couch shifts in the XYZ directions as recommended by BAT system were made and recorded. 4698 couch shifts for 42 patients were analyzed to study the correlations between interfraction prostate shifts vs bladder, rectum, and prostate volumes on planning CT. Results: Mean and range of volumes (cc): Bladder: 179 (42-582), rectum: 108 (28-223), and prostate: 55 (21-154). Mean systematic prostate shifts were (cm, ±SD) right and left lateral: -0.047±0.16 (-0.361-0.251), anterior and posterior: 0.14±0.3 (-0.466-0.669), and superior and inferior: 0.19±0.26 (-0.342-0.633). Bladder volume was not correlated with lateral, anterior/posterior, and superior/inferior prostate shifts (P>0.2). Rectal volume was correlated with anterior/posterior (P 0.2). The smaller the rectal volume or cross sectional area, the larger was the prostate shift anteriorly and vice versa (P 0.2). The smaller the prostate volume, the larger was prostate shift superiorly and vice versa (P<0.05). Conclusions: Prostate and rectal volumes, but not bladder volumes, on treatment planning CT influenced prostate position on treatment fractions. Daily image-guided adoptive radiotherapy would be required for patients with distended or empty rectum on planning CT to reduce rectal toxicity in the case of empty rectum and to minimize geometric miss of prostate.

  5. Multiview alignment hashing for efficient image search.

    Science.gov (United States)

    Liu, Li; Yu, Mengyang; Shao, Ling

    2015-03-01

    Hashing is a popular and efficient method for nearest neighbor search in large-scale data spaces by embedding high-dimensional feature descriptors into a similarity preserving Hamming space with a low dimension. For most hashing methods, the performance of retrieval heavily depends on the choice of the high-dimensional feature descriptor. Furthermore, a single type of feature cannot be descriptive enough for different images when it is used for hashing. Thus, how to combine multiple representations for learning effective hashing functions is an imminent task. In this paper, we present a novel unsupervised multiview alignment hashing approach based on regularized kernel nonnegative matrix factorization, which can find a compact representation uncovering the hidden semantics and simultaneously respecting the joint probability distribution of data. In particular, we aim to seek a matrix factorization to effectively fuse the multiple information sources meanwhile discarding the feature redundancy. Since the raised problem is regarded as nonconvex and discrete, our objective function is then optimized via an alternate way with relaxation and converges to a locally optimal solution. After finding the low-dimensional representation, the hashing functions are finally obtained through multivariable logistic regression. The proposed method is systematically evaluated on three data sets: 1) Caltech-256; 2) CIFAR-10; and 3) CIFAR-20, and the results show that our method significantly outperforms the state-of-the-art multiview hashing techniques.

  6. Impact of different setup approaches in image-guided radiotherapy as primary treatment for prostate cancer. A study of 2940 setup deviations in 980 MVCTs

    International Nuclear Information System (INIS)

    Schiller, Kilian; Specht, Hanno; Kampfer, Severin; Duma, Marciana Nona; Petrucci, Alessia; Geinitz, Hans; Schuster, Tibor

    2014-01-01

    The goal of this study was to assess the impact of different setup approaches in image-guided radiotherapy (IMRT) of the prostatic gland. In all, 28 patients with prostate cancer were enrolled in this study. After the placement of an endorectal balloon, the planning target volume (PTV) was treated to a dose of 70 Gy in 35 fractions. A simultaneously integrated boost (SIB) of 76 Gy (2.17 Gy per fraction and per day) was delivered to a smaller target volume. All patients underwent daily prostate-aligned IGRT by megavoltage CT (MVCT). Retrospectively, three different setup approaches were evaluated by comparison to the prostate alignment: setup by skin alignment, endorectal balloon alignment, and automatic registration by bones. A total of 2,940 setup deviations were analyzed in 980 fractions. Compared to prostate alignment, skin mark alignment was associated with substantial displacements, which were ≥ 8 mm in 13 %, 5 %, and 44 % of all fractions in the lateral, longitudinal, and vertical directions, respectively. Endorectal balloon alignment yielded displacements ≥ 8 mm in 3 %, 19 %, and 1 % of all setups; and ≥ 3 mm in 27 %, 58 %, and 18 % of all fractions, respectively. For bone matching, the values were 1 %, 1 %, and 2 % and 3 %, 11 %, and 34 %, respectively. For prostate radiotherapy, setup by skin marks alone is inappropriate for patient positioning due to the fact that, during almost half of the fractions, parts of the prostate would not be targeted successfully with an 8-mm safety margin. Bone matching performs better but not sufficiently for safety margins ≤ 3 mm. Endorectal balloon matching can be combined with bone alignment to increase accuracy in the vertical direction when prostate-based setup is not available. Daily prostate alignment remains the gold standard for high-precision radiotherapy with small safety margins. (orig.) [de

  7. Magnetic resonance imaging in prostate disease. Review of 58 cases

    Energy Technology Data Exchange (ETDEWEB)

    Gevenois, P.A.; Van Regemorter, G.; Van Gansbeke, D.; Delcour, C.; Corbusier, A.; Struyven, J.

    1987-03-01

    Forty-eight patients with prostatic disease (benign prostatic hyperplasia (B.P.H.), carcinoma, cysts, myoma and prostatitis) and 10 normal volunteers underwent magnetic resonance imaging (M.R.I) of the prostate. The prostatic parenchyma was best evaluated by a T2-weighted spin-echo pulse sequence. The prostate in patients with B.P.H. often had an homogeneous or more rarely a nodular appearance on T2-weighted images. In most cases, a peripheral dark rim is observed. All prostate in patients with carcinoma had an heterogeneous appearance on T2-weighted images. While most of the prostatic carcinomas appeared hypointense relative to adjacent prostatic parenchyma, some of the neoplasms had a high or mixed-high and low signal. The myoma showed a low-signal nodule like carcinoma. The cyst appears as a liquid tumor. The prostatitis had an homogeneous bright signal. With the used methodology, MRI can differentiate prostatic diseases in many cases. Nevertheless the technique has to be optimalized to improve its accuracy.

  8. Magnetic resonance imaging in prostate disease. Review of 58 cases

    International Nuclear Information System (INIS)

    Gevenois, P.A.; Van Regemorter, G.; Van Gansbeke, D.; Delcour, C.; Corbusier, A.; Struyven, J.

    1987-01-01

    Forty-eight patients with prostatic disease (benign prostatic hyperplasia (B.P.H.), carcinoma, cysts, myoma and prostatitis) and 10 normal volunteers underwent magnetic resonance imaging (M.R.I) of the prostate. The prostatic parenchyma was best evaluated by a T2-weighted spin-echo pulse sequence. The prostate in patients with B.P.H. often had an homogeneous or more rarely a nodular appearance on T2-weighted images. In most cases, a peripheral dark rim is observed. All prostate in patients with carcinoma had an heterogeneous appearance on T2-weighted images. While most of the prostatic carcinomas appeared hypointense relative to adjacent prostatic parenchyma, some of the neoplasms had a high or mixed-high and low signal. The myoma showed a low-signal nodule like carcinoma. The cyst appears as a liquid tumor. The prostatitis had an homogeneous bright signal. With the used methodology, MRI can differentiate prostatic diseases in many cases. Nevertheless the technique has to be optimalized to improve its accuracy [fr

  9. A Practical Guide to Multi-image Alignment

    OpenAIRE

    Aguerrebere, Cecilia; Delbracio, Mauricio; Bartesaghi, Alberto; Sapiro, Guillermo

    2018-01-01

    Multi-image alignment, bringing a group of images into common register, is an ubiquitous problem and the first step of many applications in a wide variety of domains. As a result, a great amount of effort is being invested in developing efficient multi-image alignment algorithms. Little has been done, however, to answer fundamental practical questions such as: what is the comparative performance of existing methods? is there still room for improvement? under which conditions should one techni...

  10. Markov random field based automatic image alignment for electron tomography.

    Science.gov (United States)

    Amat, Fernando; Moussavi, Farshid; Comolli, Luis R; Elidan, Gal; Downing, Kenneth H; Horowitz, Mark

    2008-03-01

    We present a method for automatic full-precision alignment of the images in a tomographic tilt series. Full-precision automatic alignment of cryo electron microscopy images has remained a difficult challenge to date, due to the limited electron dose and low image contrast. These facts lead to poor signal to noise ratio (SNR) in the images, which causes automatic feature trackers to generate errors, even with high contrast gold particles as fiducial features. To enable fully automatic alignment for full-precision reconstructions, we frame the problem probabilistically as finding the most likely particle tracks given a set of noisy images, using contextual information to make the solution more robust to the noise in each image. To solve this maximum likelihood problem, we use Markov Random Fields (MRF) to establish the correspondence of features in alignment and robust optimization for projection model estimation. The resulting algorithm, called Robust Alignment and Projection Estimation for Tomographic Reconstruction, or RAPTOR, has not needed any manual intervention for the difficult datasets we have tried, and has provided sub-pixel alignment that is as good as the manual approach by an expert user. We are able to automatically map complete and partial marker trajectories and thus obtain highly accurate image alignment. Our method has been applied to challenging cryo electron tomographic datasets with low SNR from intact bacterial cells, as well as several plastic section and X-ray datasets.

  11. Automatic registration of multi-modal microscopy images for integrative analysis of prostate tissue sections

    International Nuclear Information System (INIS)

    Lippolis, Giuseppe; Edsjö, Anders; Helczynski, Leszek; Bjartell, Anders; Overgaard, Niels Chr

    2013-01-01

    Prostate cancer is one of the leading causes of cancer related deaths. For diagnosis, predicting the outcome of the disease, and for assessing potential new biomarkers, pathologists and researchers routinely analyze histological samples. Morphological and molecular information may be integrated by aligning microscopic histological images in a multiplex fashion. This process is usually time-consuming and results in intra- and inter-user variability. The aim of this study is to investigate the feasibility of using modern image analysis methods for automated alignment of microscopic images from differently stained adjacent paraffin sections from prostatic tissue specimens. Tissue samples, obtained from biopsy or radical prostatectomy, were sectioned and stained with either hematoxylin & eosin (H&E), immunohistochemistry for p63 and AMACR or Time Resolved Fluorescence (TRF) for androgen receptor (AR). Image pairs were aligned allowing for translation, rotation and scaling. The registration was performed automatically by first detecting landmarks in both images, using the scale invariant image transform (SIFT), followed by the well-known RANSAC protocol for finding point correspondences and finally aligned by Procrustes fit. The Registration results were evaluated using both visual and quantitative criteria as defined in the text. Three experiments were carried out. First, images of consecutive tissue sections stained with H&E and p63/AMACR were successfully aligned in 85 of 88 cases (96.6%). The failures occurred in 3 out of 13 cores with highly aggressive cancer (Gleason score ≥ 8). Second, TRF and H&E image pairs were aligned correctly in 103 out of 106 cases (97%). The third experiment considered the alignment of image pairs with the same staining (H&E) coming from a stack of 4 sections. The success rate for alignment dropped from 93.8% in adjacent sections to 22% for sections furthest away. The proposed method is both reliable and fast and therefore well suited

  12. Quality measures for HRR alignment based ISAR imaging algorithms

    CSIR Research Space (South Africa)

    Janse van Rensburg, V

    2013-05-01

    Full Text Available Some Inverse Synthetic Aperture Radar (ISAR) algorithms form the image in a two-step process of range alignment and phase conjugation. This paper discusses a comprehensive set of measures used to quantify the quality of range alignment, with the aim...

  13. Development of a semi-automatic alignment tool for accelerated localization of the prostate

    International Nuclear Information System (INIS)

    Hua Chiaho; Lovelock, D. Michael; Mageras, Gikas S.; Katz, Matthew S.; Mechalakos, James; Lief, Eugene P.; Hollister, Timothy; Lutz, Wendell R.; Zelefsky, Michael J.; Ling, Clifton C.

    2003-01-01

    -fitting correction, 97% of the scans showed that the entire posterior prostate gland was covered by PTV given a margin of 6 mm at the rectum-prostate interface and 10 mm elsewhere. In comparison, only 74% and 65% could be achieved by the corrections based on daily and weekly bony matching on portal images, respectively. Conclusions: Results show that daily CT extent fitting provides a precise correction of prostate position in terms of CoG. Identifying prostate extents on five axial CT slices at the CT console is less time-consuming compared with daily contouring of the prostate on many slices. Taking advantage of the prostate curvature in the longitudinal direction, this method also eliminates the necessity of identifying prostate base and apex. Therefore, it is clinically feasible and should provide an accelerated localization of the prostate immediately before daily treatment

  14. Extraction of prostatic lumina and automated recognition for prostatic calculus image using PCA-SVM.

    Science.gov (United States)

    Wang, Zhuocai; Xu, Xiangmin; Ding, Xiaojun; Xiao, Hui; Huang, Yusheng; Liu, Jian; Xing, Xiaofen; Wang, Hua; Liao, D Joshua

    2011-01-01

    Identification of prostatic calculi is an important basis for determining the tissue origin. Computation-assistant diagnosis of prostatic calculi may have promising potential but is currently still less studied. We studied the extraction of prostatic lumina and automated recognition for calculus images. Extraction of lumina from prostate histology images was based on local entropy and Otsu threshold recognition using PCA-SVM and based on the texture features of prostatic calculus. The SVM classifier showed an average time 0.1432 second, an average training accuracy of 100%, an average test accuracy of 93.12%, a sensitivity of 87.74%, and a specificity of 94.82%. We concluded that the algorithm, based on texture features and PCA-SVM, can recognize the concentric structure and visualized features easily. Therefore, this method is effective for the automated recognition of prostatic calculi.

  15. Extraction of Prostatic Lumina and Automated Recognition for Prostatic Calculus Image Using PCA-SVM

    Science.gov (United States)

    Wang, Zhuocai; Xu, Xiangmin; Ding, Xiaojun; Xiao, Hui; Huang, Yusheng; Liu, Jian; Xing, Xiaofen; Wang, Hua; Liao, D. Joshua

    2011-01-01

    Identification of prostatic calculi is an important basis for determining the tissue origin. Computation-assistant diagnosis of prostatic calculi may have promising potential but is currently still less studied. We studied the extraction of prostatic lumina and automated recognition for calculus images. Extraction of lumina from prostate histology images was based on local entropy and Otsu threshold recognition using PCA-SVM and based on the texture features of prostatic calculus. The SVM classifier showed an average time 0.1432 second, an average training accuracy of 100%, an average test accuracy of 93.12%, a sensitivity of 87.74%, and a specificity of 94.82%. We concluded that the algorithm, based on texture features and PCA-SVM, can recognize the concentric structure and visualized features easily. Therefore, this method is effective for the automated recognition of prostatic calculi. PMID:21461364

  16. Endorectal magnetic resonance imaging of the prostate and bladder

    International Nuclear Information System (INIS)

    Sugimura, Yoshiki; Hayashi, Norio; Yamashita, Atsushi; Kinbara, Hiroyuki; Arima, Kiminobu; Tochigi, Hiromi; Kawamura, Juichi

    1994-01-01

    Endorectal magnetic resonance imaging (MRI) using an endorectal surface coil has been evaluated basically and clinically. This new modality obtained increased resolution magnetic resonance images of the pathologic conditions of the prostate and bladder. Compared with images obtained with a body coil, the surface coil images clearly demonstrate prostatic intraglandular zonal anatomy. The clear images of prostatic capsule and neurovascular bundle seen on the surface coil may contribute to the local staging of prostate cancer. The staging diagnosis of bladder tumor located in the bladder neck will be the best candidate for endorectal MRI. Enhancement with gadolinium may improve the ability to differentiate superficial from deep bladder-wall tumors. We concluded that endorectal MRI is safely performed and is extremely useful for the local staging of prostate cancer and bladder neck tumor. Further studies will be required to evaluate the clinical significance of this new modality. (author)

  17. Feature-based Alignment of Volumetric Multi-modal Images

    Science.gov (United States)

    Toews, Matthew; Zöllei, Lilla; Wells, William M.

    2014-01-01

    This paper proposes a method for aligning image volumes acquired from different imaging modalities (e.g. MR, CT) based on 3D scale-invariant image features. A novel method for encoding invariant feature geometry and appearance is developed, based on the assumption of locally linear intensity relationships, providing a solution to poor repeatability of feature detection in different image modalities. The encoding method is incorporated into a probabilistic feature-based model for multi-modal image alignment. The model parameters are estimated via a group-wise alignment algorithm, that iteratively alternates between estimating a feature-based model from feature data, then realigning feature data to the model, converging to a stable alignment solution with few pre-processing or pre-alignment requirements. The resulting model can be used to align multi-modal image data with the benefits of invariant feature correspondence: globally optimal solutions, high efficiency and low memory usage. The method is tested on the difficult RIRE data set of CT, T1, T2, PD and MP-RAGE brain images of subjects exhibiting significant inter-subject variability due to pathology. PMID:24683955

  18. Imaging Prostatic Lipids to Distinguish Aggressive Prostate Cancer

    Science.gov (United States)

    2016-12-01

    prostatectomy samples, intraprostatic lipid as measured by MRSI and prostate tumor aggressiveness. 3) To quantify key metabolic intermediates involved in...lipid as measured by 1H MRSI, and prostate tumor aggressiveness; and 3) quantify the association between key metabolic intermediates involved in lipid

  19. Fast 3-T MR-guided transrectal prostate biopsy using an in-room tablet device for needle guide alignment: a feasibility study.

    Science.gov (United States)

    Overduin, Christiaan G; Heidkamp, Jan; Rothgang, Eva; Barentsz, Jelle O; de Lange, Frank; Fütterer, Jurgen J

    2018-05-22

    To assess the feasibility of adding a tablet device inside the scanner room to assist needle-guide alignment during magnetic resonance (MR)-guided transrectal prostate biopsy. Twenty patients with one cancer-suspicious region (CSR) with PI-RADS score ≥ 4 on diagnostic multiparametric MRI were prospectively enrolled. Two orthogonal scan planes of an MR fluoroscopy sequence (~3 images/s) were aligned to the CSR and needle-guide pivoting point. Targeting was achieved by manipulating the needle-guide under MR fluoroscopy feedback on the in-room tablet device. Technical feasibility and targeting success were assessed. Complications and biopsy procedure times were also recorded. Needle-guide alignment with the in-room tablet device was technically successful in all patients and allowed sampling after a single alignment step in 19/20 (95%) CSRs (median size 14 mm, range: 4-45). Biopsy cores contained cancer in 18/20 patients. There were no per-procedural or post-biopsy complications. Using the tablet device, the mean time to first biopsy was 5.8 ± 1.0 min and the mean total procedure time was 23.7 ± 4.1 min. Use of an in-room tablet device to assist needle-guide alignment was feasible and safe during MR-guided transrectal prostate biopsy. Initial experience indicates potential for procedure time reduction. • Performing MR-guided prostate biopsy using an in-room tablet device is feasible. • CSRs could be sampled after a single alignment step in 19/20 patients. • The mean procedure time for biopsy with the tablet device was 23.7 min.

  20. Dosimetric impact of image-guided 3D conformal radiation therapy of prostate cancer

    International Nuclear Information System (INIS)

    Schaly, B; Song, W; Bauman, G S; Battista, J J; Van Dyk, J

    2005-01-01

    The goal of this work is to quantify the impact of image-guided conformal radiation therapy (CRT) on the dose distribution by correcting patient setup uncertainty and inter-fraction tumour motion. This was a retrospective analysis that used five randomly selected prostate cancer patients that underwent approximately 15 computed tomography (CT) scans during their radiation treatment course. The beam arrangement from the treatment plan was imported into each repeat CT study and the dose distribution was recalculated for the new beam setups. Various setup scenarios were then compared to assess the impact of image guidance on radiation treatment precision. These included (1) daily alignment to skin markers, thus representing a conventional beam setup without image guidance (2) alignment to bony anatomy for correction of daily patient setup error, thus representing on-line portal image guidance, and (3) alignment to the 'CTV of the day' for correction of inter-fraction tumour motion, thus representing on-line CT or ultrasound image guidance. Treatment scenarios (1) and (3) were repeated with a reduced CTV to PTV margin, where the former represents a treatment using small margins without daily image guidance. Daily realignment of the treatment beams to the prostate showed an average increase in minimum tumour dose of 1.5 Gy, in all cases where tumour 'geographic miss' without image guidance was apparent. However, normal tissue sparing did not improve unless the PTV margin was reduced. Daily realignment to the tumour combined with reducing the margin size by a factor of 2 resulted in an average escalation in tumour dose of 9.0 Gy for all five static plans. However, the prescription dose could be escalated by 13.8 Gy when accounting for changes in anatomy by accumulating daily doses using nonlinear image registration techniques. These results provide quantitative information on the effectiveness of image-guided radiation treatment of prostate cancer and demonstrate that

  1. ALIGNING THE BRAND IDENTITY AND BRAND IMAGE AFTER REBRANDING

    Directory of Open Access Journals (Sweden)

    Cătălin Mihail BARBU

    2016-11-01

    Full Text Available The brand identity and brand image are two concepts used extensively in positioning. Many brands underwent a rebranding process attempting to improve their positioning. The rebranding process can bring minor changes or substantial changes. Following the substantial changes, there can appear a mismatch between the desired identity and brand image. Brand image is persistent and it takes time to change it. This paper explores the challenges involved by the calibration of the identity and of the image in the process of rebranding. The alignment process is a dynamic one, an interactive and not a normative one. The results of this study highlight the elements that support the brand identity and image alignment: marketing communication, product characteristics and internal brand strength. On the other side, the efforts to align the brand identity and brand image are negatively affected by the attitudes of the consumers and their past experience with the brand.

  2. Evaluation of Multimodal Imaging Biomarkers of Prostate Cancer

    Science.gov (United States)

    2016-11-01

    relationship prostate cancer growth, androgen receptor (AR) levels, hypoxia, and translocator protein (TSPO) levels. As described in the statement of work... bladder uptake) that enable robust detection of small prostate cancers . In contrast, high background and variable uptake of FDHT and FMISO confounded the...Award Number: W81XWH-12-1-0245 TITLE: Evaluation of Multimodal Imaging Biomarkers of Prostate Cancer PRINCIPAL INVESTIGATOR: Christopher Chad

  3. Computer vision applications for coronagraphic optical alignment and image processing.

    Science.gov (United States)

    Savransky, Dmitry; Thomas, Sandrine J; Poyneer, Lisa A; Macintosh, Bruce A

    2013-05-10

    Modern coronagraphic systems require very precise alignment between optical components and can benefit greatly from automated image processing. We discuss three techniques commonly employed in the fields of computer vision and image analysis as applied to the Gemini Planet Imager, a new facility instrument for the Gemini South Observatory. We describe how feature extraction and clustering methods can be used to aid in automated system alignment tasks, and also present a search algorithm for finding regular features in science images used for calibration and data processing. Along with discussions of each technique, we present our specific implementation and show results of each one in operation.

  4. A Comparison of daily megavoltage CT and ultrasound image guided radiation therapy for prostate cancer

    International Nuclear Information System (INIS)

    Peng Cheng; Kainz, Kristofer; Lawton, Colleen; Li, X. Allen

    2008-01-01

    In order to quantify the differences between ultrasound-imaging and megavoltage-CT (MVCT) daily prostate localization in prostate-cancer radiotherapy and their dosimetric impacts, daily shifts were analyzed for a total of 140 prostate cancer patients; 106 positioned using ultrasound-based imaging [B-mode Acquisition and Targeting (BAT)], and 34 using the MVCT from a TomoTherapy Hi-Art unit. The shifts indicated by the two systems were compared statistically along the right/left (R/L), superior/inferior (S/I), and anterior/posterior (A/P) directions. The systematic and random variations among the daily alignments were calculated. Margins to account for these shifts were estimated. The mean shifts and standard deviations along the R/L, S/I, and A/P directions were -0.11±3.80, 0.67±4.67, and 2.71±6.31 mm for BAT localizations and -0.98±5.13, 0.27±3.35, and 1.00±4.22 mm for MVCT localizations, respectively. The systematic and random variations in daily shifts based on MVCT were generally smaller than those based on BAT, especially along the A/P direction. A t-test showed this difference to be statistically significant. The planning target volume margins in the A/P direction estimated to account for daily variations were 8.81 and 14.66 mm based on MVCT and BAT data, respectively. There was no statistically significant difference in the daily prostate movement pattern between the first few fractions and the remaining fractions. Dosimetric comparison of MVCT and BAT prostate alignments was performed for seven fractions from a patient. The degradation from the plan caused by the MVCT alignment is trivial, while that by BAT is substantial. The MVCT technique results in smaller variations in daily shifts than ultrasound imaging, indicating that MVCT is more reliable and precise for prostate localization. Ultrasound-based localization may overestimate the daily prostate motion, particularly in the A/P direction, negatively impacting prostate dose coverage and rectal

  5. A Comparison of daily megavoltage CT and ultrasound image guided radiation therapy for prostate cancer

    Energy Technology Data Exchange (ETDEWEB)

    Peng Cheng; Kainz, Kristofer; Lawton, Colleen; Li, X. Allen [Department of Radiation Oncology, Medical College of Wisconsin, Milwaukee, Wisconsin 53226 (United States)

    2008-12-15

    In order to quantify the differences between ultrasound-imaging and megavoltage-CT (MVCT) daily prostate localization in prostate-cancer radiotherapy and their dosimetric impacts, daily shifts were analyzed for a total of 140 prostate cancer patients; 106 positioned using ultrasound-based imaging [B-mode Acquisition and Targeting (BAT)], and 34 using the MVCT from a TomoTherapy Hi-Art unit. The shifts indicated by the two systems were compared statistically along the right/left (R/L), superior/inferior (S/I), and anterior/posterior (A/P) directions. The systematic and random variations among the daily alignments were calculated. Margins to account for these shifts were estimated. The mean shifts and standard deviations along the R/L, S/I, and A/P directions were -0.11{+-}3.80, 0.67{+-}4.67, and 2.71{+-}6.31 mm for BAT localizations and -0.98{+-}5.13, 0.27{+-}3.35, and 1.00{+-}4.22 mm for MVCT localizations, respectively. The systematic and random variations in daily shifts based on MVCT were generally smaller than those based on BAT, especially along the A/P direction. A t-test showed this difference to be statistically significant. The planning target volume margins in the A/P direction estimated to account for daily variations were 8.81 and 14.66 mm based on MVCT and BAT data, respectively. There was no statistically significant difference in the daily prostate movement pattern between the first few fractions and the remaining fractions. Dosimetric comparison of MVCT and BAT prostate alignments was performed for seven fractions from a patient. The degradation from the plan caused by the MVCT alignment is trivial, while that by BAT is substantial. The MVCT technique results in smaller variations in daily shifts than ultrasound imaging, indicating that MVCT is more reliable and precise for prostate localization. Ultrasound-based localization may overestimate the daily prostate motion, particularly in the A/P direction, negatively impacting prostate dose coverage

  6. Prostatic MR imaging. Accuracy in differentiating cancer from other prostatic disorders

    Energy Technology Data Exchange (ETDEWEB)

    Ikonen, S.; Kivisaari, L.; Tervahartiala, P. [Helsinki Univ. Central Hospital (Finland). Dept of Radiology; Vehmas, T. [Finnish Inst. of Occupational Health, Helsinki (Finland); Taari, K.; Rannikko, S. [Helsinki Univ. Central Hospital (Finland). Dept of Urology

    2001-03-01

    Purpose: We assessed the accuracy of MR imaging in differentiating between cancer and other prostatic disorders, and evaluated the diagnostic criteria for various prostatic diseases. Material and Methods: A total of 74 endorectal coil MR studies were performed on 72 patients. Twenty patients had prostatic cancer, 20 benign prostatic hyperplasia (BPH), 4 acute bacterial prostatitis, 5 chronic bacterial prostatitis (2 also belonging to the previous category), 19 chronic non-bacterial prostatitis/chronic pelvic pain syndrome, and 6 were symptomless voluntary controls. All studies were interpreted by two experienced radiologists in random order. Radiologists were blinded to all clinical data including the age of the patients. Based on MR findings, both radiologists filled in a form covering diagnostic criteria and diagnosis. Results: Accuracy in diagnosing prostate cancer was 74%. Sensitivity was 50% and specificity 83%, and positive and negative predictive values were 53 and 82%, respectively. Bacterial prostatitis showed some features similar to carcinoma. Abundant BPH rendered cancer detection more difficult. No diagnostic criterion was clearly better than the others. Interobserver agreement on the MR diagnosis ranged from moderate to good. Conclusion: Without knowledge of accurate clinical data, MR seems to be too insensitive in detecting prostate cancer to be used as a primary diagnostic tool.

  7. Systematic Image Based Optical Alignment and Tensegrity

    Science.gov (United States)

    Zeiders, Glenn W.; Montgomery, Edward E, IV (Technical Monitor)

    2001-01-01

    This presentation will review the objectives and current status of two Small Business Innovative Research being performed by the Sirius Group, under the direction of MSFC. They all relate to the development of advanced optical systems technologies for automated segmented mirror alignment techniques and fundamental design methodologies for ultralight structures. These are important to future astronomical missions in space.

  8. Evaluation of Image-Guidance Strategies in the Treatment of Localized Prostate Cancer

    International Nuclear Information System (INIS)

    Kupelian, Patrick A.; Lee, Choonik; Langen, Katja M.; Zeidan, Omar A.; Manon, Rafael R.; Willoughby, Twyla R.; Meeks, Sanford L.

    2008-01-01

    Purpose: To compare different image-guidance strategies in the alignment of prostate cancer patients. Using data from patients treated using daily image guidance, the remaining setup errors for several different strategies were retrospectively calculated. Methods and Materials: The alignment data from 74 patients treated with helical tomotherapy were analyzed, resulting in a data set of 2,252 fractions during which a megavoltage computed tomography image was used for image guidance with intraprostatic metallic fiducials. Given the daily positional adjustments, a variety of protocols, differing in imaging frequency and method, were retrospectively studied. The residual setup errors were determined for each protocol. Results: As expected, the systematic errors were effectively reduced with imaging. However, the random errors were unaffected. Even when image guidance was performed every other day with a running mean of the previous displacements, residual setup errors >5 mm occurred in 24% of all fractions. This frequency increased to about 40% if setup errors >3 mm were scored. Conclusion: Setup errors increased with decreasing frequency of image guidance. However, residual errors were still significant at the 5-mm level, even with imaging was performed every other day. This suggests that localizations must be performed daily in the set up of prostate cancer patients during a course of external beam radiotherapy

  9. MR imaging of the prostate; MRT der Prostata

    Energy Technology Data Exchange (ETDEWEB)

    Asbach, P.; Haas, M.; Hamm, B. [Charite Campus Benjamin Franklin, Klinik fuer Radiologie, Berlin (Germany)

    2015-12-15

    Prostate cancer is the most common form of cancer in men in Germany; however, there is a distinct difference between incidence and mortality. The detection of prostate cancer is based on clinical and laboratory testing using serum prostate-specific antigen (PSA) levels and transrectal ultrasound with randomized biopsy. Multiparametric MR imaging of the prostate can provide valuable diagnostic information for detection of prostate cancer, especially after negative results of a biopsy prior to repeat biopsy. In addition the use of MR ultrasound fusion-guided biopsy has gained in diagnostic importance and has increased the prostate cancer detection rate. The prostate imaging reporting and data system (PI-RADS) classification has standardized the reporting of prostate MRI which has positively influenced the acceptance by urologists. (orig.) [German] Das Prostatakarzinom ist in Deutschland die haeufigste Krebserkrankung des Mannes, wobei ein deutlicher Unterschied zwischen Inzidenz und Mortalitaet besteht. Die Detektion des Prostatakarzinoms basiert auf klinischer und laborchemischer Untersuchung (prostataspezifisches-Antigen[PSA]-Wert) sowie der transrektalen Ultraschalluntersuchung mit randomisierter Biopsie. Die multiparametrische MR-Tomographie kann zur Detektion des Prostatakarzinoms, insbesondere bei negativer Biopsie vor einer erneuten Biopsie wertvolle diagnostische Informationen liefern. Zudem wird zunehmend die MRT-Ultraschall-Fusionsbiopsie in der Diagnostik eingesetzt, wodurch die Detektionsrate des Prostatakarzinoms deutlich gesteigert werden kann. Mit Einfuehrung der PI-RADS-Klassifikation (Prostate Imaging-Reporting and Data System) konnte zudem eine Standardisierung der Befundung erreicht werden, was die Akzeptanz der MRT der Prostata in der Urologie erhoeht hat. (orig.)

  10. Ultrasound and PET-CT image fusion for prostate brachytherapy image guidance

    International Nuclear Information System (INIS)

    Hasford, F.

    2015-01-01

    , indicating the system’s ability to visualize low contrast objects 5.4 cm into a patient. PET-CT system’s performance evaluation also produced satisfactory results in accordance with set tolerances as recommended by IAEA Human Health Series 1. Computed tomography laser alignment test ensured that all CT gantry lasers were properly aligned with the patient bed. Image display width test ensured that volume of patient or organ being measured and displayed was equivalent to that selected on the CT scanner console, to a deviation of ± 1 mm. Results from CT image uniformity test showed that mean CT numbers in peripheral regions of interest deviated from the central mean to within recommended tolerance level of ± 5 HU, indicating a good level of uniformity. Computed tomographic dose indices for head and body phantoms were estimated as 44.30 mGy and 20.08 mGy, comparative to console displayed doses of 42.40 mGy and 19.49 mGy respectively. Registration accuracy for PET-CT images was to have displacements of less than 1 mm in x, y and z directions. Image quality of PET-CT images was performed to produce images simulating those obtained in a total body imaging study involving both hot and cold lesions. Percentage contrast estimates of 49.3% and 52.6% were obtained for hot spheres of diameters 1.3 cm and 2.2 cm respectively, while contrast estimates of 74.8% and 75.6% were obtained for cold spheres of diameters 2.8 cm and 3.7 cm respectively. The PET-CT system resolution was estimated as 0.5 ± 0.01 cm, indicating the system’s ability to image tumours of the size of about 5 mm. Satisfactory results from the performance evaluation of ultrasound and PET-CT systems, paved way for them to be used in acquiring prostatic images for the study. Developed MATLAB image enhancement algorithm enhanced the quality of prostatic images before fusion. The algorithm was developed by mapping the intensity values in raw images to new values in a modified image using imadjust function. Contrast

  11. Spatio-temporal alignment of pedobarographic image sequences.

    Science.gov (United States)

    Oliveira, Francisco P M; Sousa, Andreia; Santos, Rubim; Tavares, João Manuel R S

    2011-07-01

    This article presents a methodology to align plantar pressure image sequences simultaneously in time and space. The spatial position and orientation of a foot in a sequence are changed to match the foot represented in a second sequence. Simultaneously with the spatial alignment, the temporal scale of the first sequence is transformed with the aim of synchronizing the two input footsteps. Consequently, the spatial correspondence of the foot regions along the sequences as well as the temporal synchronizing is automatically attained, making the study easier and more straightforward. In terms of spatial alignment, the methodology can use one of four possible geometric transformation models: rigid, similarity, affine, or projective. In the temporal alignment, a polynomial transformation up to the 4th degree can be adopted in order to model linear and curved time behaviors. Suitable geometric and temporal transformations are found by minimizing the mean squared error (MSE) between the input sequences. The methodology was tested on a set of real image sequences acquired from a common pedobarographic device. When used in experimental cases generated by applying geometric and temporal control transformations, the methodology revealed high accuracy. In addition, the intra-subject alignment tests from real plantar pressure image sequences showed that the curved temporal models produced better MSE results (P alignment of pedobarographic image data, since previous methods can only be applied on static images.

  12. Comparison of prostate contours between conventional stepping transverse imaging and Twister-based sagittal imaging in permanent interstitial prostate brachytherapy.

    Science.gov (United States)

    Kawakami, Shogo; Ishiyama, Hiromichi; Satoh, Takefumi; Tsumura, Hideyasu; Sekiguchi, Akane; Takenaka, Kouji; Tabata, Ken-Ichi; Iwamura, Masatsugu; Hayakawa, Kazushige

    2017-08-01

    To compare prostate contours on conventional stepping transverse image acquisitions with those on twister-based sagittal image acquisitions. Twenty prostate cancer patients who were planned to have permanent interstitial prostate brachytherapy were prospectively accrued. A transrectal ultrasonography probe was inserted, with the patient in lithotomy position. Transverse images were obtained with stepping movement of the transverse transducer. In the same patient, sagittal images were also obtained through rotation of the sagittal transducer using the "Twister" mode. The differences of prostate size among the two types of image acquisitions were compared. The relationships among the difference of the two types of image acquisitions, dose-volume histogram (DVH) parameters on the post-implant computed tomography (CT) analysis, as well as other factors were analyzed. The sagittal image acquisitions showed a larger prostate size compared to the transverse image acquisitions especially in the anterior-posterior (AP) direction ( p transverse image acquisitions was correlated to DVH parameters such as D 90 ( R = 0.518, p = 0.019), and V 100 ( R = 0.598, p = 0.005). There were small but significant differences in the prostate contours between the transverse and the sagittal planning image acquisitions. Furthermore, our study suggested that the differences between the two types of image acquisitions might correlated to dosimetric results on CT analysis.

  13. Multiparametric magnetic resonance imaging in the detection of prostate cancer

    International Nuclear Information System (INIS)

    Durmus, T.; Baur, A.; Hamm, B.

    2014-01-01

    Prostate cancer is the most common malignancy in men, but only about 10 % of patients die from that cancer. Recent studies suggest that not all patients benefit from a radical therapeutic approach. When prostate cancer is suspected, magnetic resonance imaging (MRI) can make an important contribution to cancer localization within the prostate. Many studies show that T2-weighted morphologic imaging should be supplemented by multiparametric MRI techniques including diffusion-weighted imaging, contrast-enhanced sequences, and MR spectroscopy. This approach detects aggressive prostate cancer with high sensitivity and specificity. The findings of multiparametric MRI additionally contribute information to the assessment of cancer aggressiveness. The use of these multiparametric MRI techniques will gain an increasing role in the clinical management of prostate cancer patients. They can help in establishing a definitive diagnosis with a minimum of invasiveness and may also contribute to optimal individualized treatment. This review article presents the different techniques of multiparametric MRI and discusses their contribution to the detection of prostate cancer. Moreover, this review outlines an objective approach to image interpretation and structured reporting of MRI findings using the PI-RADS criteria. The review concludes with an outline of approaches to prostate biopsy on the basis of MRI (transrectal ultrasound, direct MRI guidance of tissue sampling, and MRI-ultrasound fusion biopsy) and emerging future uses of MRI in the planning of focal treatment options and in the active surveillance of patients diagnosed with prostate cancer. (orig.)

  14. Prostate imaging. An update; Bildgebung der Prostata. Ein Update

    Energy Technology Data Exchange (ETDEWEB)

    Franiel, T.; Teichgraeber, U. [University Hospital Jena (Germany). Dept. of Diagnostic and Interventional Radiology; Asbach, P.; Hamm, B. [University Medicine Berlin (Germany). Dept. of Radiology; Foller, S. [University Hospital Jena (Germany). Dept. of Urology

    2015-09-15

    New technical and clinical developments of sonography and magnetic resonance imaging include improved detection, localization and staging as well as active surveillance of prostate cancer. Multiparametric MRI can best answer these typical clinical questions. However, ultrasound elastography seems to be suitable for the detection of significant prostate cancer as well. The structured reporting system for multiparametric MRI of the prostate according to PI-RADS Version 1 led to improved and reproducible diagnosis of prostate cancer. The new PI-RADS Version 2 aims to minimize the limitations of Version 1 and make PI-RADS standardization more globally acceptable.

  15. Cryogenic Pupil Alignment Test Architecture for Aberrated Pupil Images

    Science.gov (United States)

    Bos, Brent; Kubalak, David A.; Antonille, Scott; Ohl, Raymond; Hagopian, John G.

    2009-01-01

    A document describes cryogenic test architecture for the James Webb Space Telescope (JWST) integrated science instrument module (ISIM). The ISIM element primarily consists of a mechanical metering structure, three science instruments, and a fine guidance sensor. One of the critical optomechanical alignments is the co-registration of the optical telescope element (OTE) exit pupil with the entrance pupils of the ISIM instruments. The test architecture has been developed to verify that the ISIM element will be properly aligned with the nominal OTE exit pupil when the two elements come together. The architecture measures three of the most critical pupil degrees-of-freedom during optical testing of the ISIM element. The pupil measurement scheme makes use of specularly reflective pupil alignment references located inside the JWST instruments, ground support equipment that contains a pupil imaging module, an OTE simulator, and pupil viewing channels in two of the JWST flight instruments. Pupil alignment references (PARs) are introduced into the instrument, and their reflections are checked using the instrument's mirrors. After the pupil imaging module (PIM) captures a reflected PAR image, the image will be analyzed to determine the relative alignment offset. The instrument pupil alignment preferences are specularly reflective mirrors with non-reflective fiducials, which makes the test architecture feasible. The instrument channels have fairly large fields of view, allowing PAR tip/tilt tolerances on the order of 0.5deg.

  16. Intraoperative panoramic image using alignment grid, is it accurate?

    Science.gov (United States)

    Apivatthakakul, T; Duanghakrung, M; Luevitoonvechkit, S; Patumasutra, S

    2013-07-01

    Minimally invasive orthopedic trauma surgery relies heavily on intraoperative fluoroscopic images to evaluate the quality of fracture reduction and fixation. However, fluoroscopic images have a narrow field of view and often cannot visualize the entire long bone axis. To compare the coronal femoral alignment between conventional X-rays to that achieved with a new method of acquiring a panoramic intraoperative image. Twenty-four cadaveric femurs with simple diaphyseal fractures were fixed with an angulated broad DCP to create coronal plane malalignment. An intraoperative alignment grid was used to help stitch different fluoroscopic images together to produce a panoramic image. A conventional X-ray of the entire femur was then performed. The coronal plane angulation in the panoramic images was then compared to the conventional X-rays using a Wilcoxon signed rank test. The mean angle measured from the panoramic view was 173.9° (range 169.3°-178.0°) with median of 173.2°. The mean angle measured from the conventional X-ray was 173.4° (range 167.7°-178.7°) with a median angle of 173.5°. There was no significant difference between both methods of measurement (P = 0.48). Panoramic images produced by stitching fluoroscopic images together with help of an alignment grid demonstrated the same accuracy at evaluating the coronal plane alignment of femur fractures as conventional X-rays.

  17. Three dimensional image alignment, registration and fusion

    International Nuclear Information System (INIS)

    Treves, S.T.; Mitchell, K.D.; Habboush, I.H.

    1998-01-01

    Combined assessment of three dimensional anatomical and functional images (SPECT, PET, MRI, CT) is useful to determine the nature and extent of lesions in many parts of the body. Physicians principally rely on their spatial sense of mentally re-orient and overlap images obtained with different imaging modalities. Objective methods that enable easy and intuitive image registration can help the physician arrive at more optimal diagnoses and better treatment decisions. This review describes a simple, intuitive and robust image registration approach developed in our laboratory. It differs from most other registration techniques in that it allows the user to incorporate all of the available information within the images in the registration process. This method takes full advantage of the ability of knowledgeable operators to achieve image registration and fusion using an intuitive interactive visual approach. It can register images accurately and quickly without the use of elaborate mathematical modeling or optimization techniques. The method provides the operator with tools to manipulate images in three dimensions, including visual feedback techniques to assess the accuracy of registration (grids, overlays, masks, and fusion of images in different colors). Its application is not limited to brain imaging and can be applied to images from any region in the body. The overall effect is a registration algorithm that is easy to implement and can achieve accuracy on the order of one pixel

  18. Multiparametric magnetic resonance imaging of the prostate: current concepts.

    NARCIS (Netherlands)

    Bittencourt, L.K.; Hausmann, D.; Sabaneeff, N.; Gasparetto, E.L.; Barentsz, J.O.

    2014-01-01

    Multiparametric MR (mpMR) imaging is rapidly evolving into the mainstay in prostate cancer (PCa) imaging. Generally, the examination consists of T2-weighted sequences, diffusion-weighted imaging (DWI), dynamic contrast-enhanced (DCE) evaluation, and less often proton MR spectroscopy imaging (MRSI).

  19. Daily Prostate Volume and Position Monitoring Using Implanted Gold Markers and On-Board Imaging during Radiotherapy

    Directory of Open Access Journals (Sweden)

    Linda Kašaová

    2011-01-01

    Full Text Available Purpose: This study aimed to evaluate prostate volume changes and prostate motions during radiotherapy. Methods: In 2010, twenty-five patients were treated for prostate cancer by external beam radiotherapy with implanted fiducial markers. Coordinates of three gold markers on kilovoltage images were calculated daily. Volume changes in target structure were observed through changes in intermarker distances. Differences in patient position between laser-tattoo alignment and gold marker localization were evaluated. Intrafraction motion was assessed by measuring marker displacement on kilovoltage images acquired before and after fraction delivery. Results: Prostate shrinkage was observed in 60% of patients. The average shrinkage was 7% of the prostate’s initial volume. Corrections after laser-tattoo alignment remained mostly below 1 cm. The difference between marker centroid position on the actual images and the planning images was 2 ± 1 mm on average. The extension of intrafraction movements was 7.6 ± 0.2 mm on average. Conclusions: In our retrospective study, the possibility for prostate volume changes during radiotherapy was revealed. Intrafraction movements turned out to be the limiting factor in safety margin reduction.

  20. Measurement of intrafractional prostate motion using magnetic resonance imaging

    International Nuclear Information System (INIS)

    Mah, Dennis; Freedman, Gary; Milestone, Bart; Hanlon, Alexandra; Palacio, Elizabeth; Richardson, Theresa; Movsas, Benjamin; Mitra, Raj; Horwitz, Eric; Hanks, Gerald E.

    2002-01-01

    Purpose: To quantify the three-dimensional intrafractional prostate motion over typical treatment time intervals with cine-magnetic resonance imaging (cine MRI) studies. Methods and Materials: Forty-two patients with prostate cancer were scanned supine in an alpha cradle cast using cine MRI. Twenty sequential slices were acquired in the sagittal and axial planes through the center of the prostate. Each scan took ∼9 min. The posterior, lateral, and superior edges of the prostate were tracked on each frame relative to the initial prostate position, and the size and duration of each displacement was recorded. Results: The prostate displacements were (mean ± SD): 0.2 ± 2.9 mm, 0.0 ± 3.4 mm, and 0.0 ± 1.5 mm in the anterior-posterior, superior-inferior, and medial-lateral dimensions respectively. The prostate motion appeared to have been driven by peristalsis in the rectum. Large displacements of the prostate (up to 1.2 cm) moved the prostate both anteriorly and superiorly and in some cases compressed the organ. For such motions, the prostate did not stay displaced, but moved back to its original position. To account for the dosimetric consequences of the motion, we also calculated the time-averaged displacement to be ∼1 mm. Conclusions: Cine MRI can be used to measure intrafractional prostate motion. Although intrafractional prostate motions occur, their effects are negligible compared to interfractional motion and setup error. No adjustment in margin is necessary for three-dimensional conformal or intensity-modulated radiation therapy

  1. Imaging prostate cancer: an update on positron emission tomography and magnetic resonance imaging

    DEFF Research Database (Denmark)

    Bouchelouche, Kirsten; Turkbey, Baris; Choyke, Peter

    2010-01-01

    , and molecular imaging information. Developments in imaging technologies, specifically magnetic resonance imaging (MRI) and positron emission tomography (PET)/computed tomography (CT), have improved the detection rate of prostate cancer. MRI has improved lesion detection and local staging. Furthermore, MRI...

  2. Feasibility study of CT perfusion imaging for prostate carcinoma

    International Nuclear Information System (INIS)

    Cullu, Nesat; Kantarci, Mecit; Ogul, Hayri; Pirimoglu, Berhan; Karaca, Leyla; Kizrak, Yesim; Adanur, Senol; Koc, Erdem; Polat, Ozkan; Okur, Aylin

    2014-01-01

    The aim of this feasibility study was to obtain initial data with which to assess the efficiency of perfusion CT imaging (CTpI) and to compare this with magnetic resonance imaging (MRI) in the diagnosis of prostate carcinoma. This prospective study involved 25 patients with prostate carcinoma undergoing MRI and CTpI. All analyses were performed on T2-weighted images (T2WI), apparent diffusion coefficient (ADC) maps, diffusion-weighted images (DWI) and CTp images. We compared the performance of T2WI combined with DWI and CTp alone. The study was approved by the local ethics committee, and written informed consent was obtained from all patients. Tumours were present in 87 areas according to the histopathological results. The diagnostic performance of the T2WI+DWI+CTpI combination was significantly better than that of T2WI alone for prostate carcinoma (P < 0.001). The diagnostic value of CTpI was similar to that of T2WI+DWI in combination. There were statistically significant differences in the blood flow and permeability surface values between prostate carcinoma and background prostate on CTp images. CTp may be a valuable tool for detecting prostate carcinoma and may be preferred in cases where MRI is contraindicated. If this technique is combined with T2WI and DWI, its diagnostic value is enhanced. (orig.)

  3. MR imaging of prostate. Preliminary experience with calculated imaging in 28 cases

    International Nuclear Information System (INIS)

    Gevenois, P.A.; Van Regemorter, G.; Ghysels, M.; Delepaut, A.; Van Gansbeke, D.; Struyven, J.

    1988-01-01

    The majority of studies with MR imaging in prostate disease are based on a semiology obtained using images weighted in T1 and T2. A study was carried out to evaluate effects of images calculated in T1 and T2 obtained at 0.5T. This preliminary study concerns 28 prostate examinations with spin-echo acquisition and inversion-recuperation parameters, and provided images calculated in T1, weighted and calculated in T2. Images allowed detection and characterization of prostate lesions. However, although calculated images accentuate discrimination of the method, the weighted images conserve their place because of their improved spatial resolution [fr

  4. Imaging Primary Prostate Cancer and Bone Metastasis

    National Research Council Canada - National Science Library

    Chen, Xiaoyuan

    2004-01-01

    ... and androgen independent prostate cancer xenografted mice. Specific Aims: (1) Design, synthesize, and characterize positrori emitting bombesin analogs, labeled with copper-64 or fluorine-I 8; (2...

  5. Improved image alignment method in application to X-ray images and biological images.

    Science.gov (United States)

    Wang, Ching-Wei; Chen, Hsiang-Chou

    2013-08-01

    Alignment of medical images is a vital component of a large number of applications throughout the clinical track of events; not only within clinical diagnostic settings, but prominently so in the area of planning, consummation and evaluation of surgical and radiotherapeutical procedures. However, image registration of medical images is challenging because of variations on data appearance, imaging artifacts and complex data deformation problems. Hence, the aim of this study is to develop a robust image alignment method for medical images. An improved image registration method is proposed, and the method is evaluated with two types of medical data, including biological microscopic tissue images and dental X-ray images and compared with five state-of-the-art image registration techniques. The experimental results show that the presented method consistently performs well on both types of medical images, achieving 88.44 and 88.93% averaged registration accuracies for biological tissue images and X-ray images, respectively, and outperforms the benchmark methods. Based on the Tukey's honestly significant difference test and Fisher's least square difference test tests, the presented method performs significantly better than all existing methods (P ≤ 0.001) for tissue image alignment, and for the X-ray image registration, the proposed method performs significantly better than the two benchmark b-spline approaches (P < 0.001). The software implementation of the presented method and the data used in this study are made publicly available for scientific communities to use (http://www-o.ntust.edu.tw/∼cweiwang/ImprovedImageRegistration/). cweiwang@mail.ntust.edu.tw.

  6. Interobserver variability of radiation therapists aligning to fiducial markers for prostate radiation therapy.

    Science.gov (United States)

    Deegan, Timothy; Owen, Rebecca; Holt, Tanya; Roberts, Lisa; Biggs, Jennifer; McCarthy, Alicia; Parfitt, Matthew; Fielding, Andrew

    2013-08-01

    As the use of fiducial markers (FMs) for the localisation of the prostate during external beam radiation therapy (EBRT) has become part of routine practice, radiation therapists (RTs) have become increasingly responsible for online image interpretation. The aim of this investigation was to quantify the limits of agreement (LoA) between RTs when localising to FMs with orthogonal kilovoltage (kV) imaging. Six patients receiving prostate EBRT utilising FMs were included in this study. Treatment localisation was performed using kV imaging prior to each fraction. Online stereoscopic assessment of FMs, performed by the treating RTs, was compared with the offline assessment by three RTs. Observer agreement was determined by pairwise Bland-Altman analysis. Stereoscopic analysis of 225 image pairs was performed online at the time of treatment, and offline by three RT observers. Eighteen pairwise Bland-Altman analyses were completed to assess the level of agreement between observers. Localisation by RTs was found to be within clinically acceptable 95% LoAs. Small differences between RTs, in both the online and offline setting, were found to be within clinically acceptable limits. RTs were able to make consistent and reliable judgements when matching FMs on planar kV imaging. © 2013 The Authors. Journal of Medical Imaging and Radiation Oncology © 2013 The Royal Australian and New Zealand College of Radiologists.

  7. Aligning Islamic Spirituality to Medical Imaging.

    Science.gov (United States)

    Zainuddin, Zainul Ibrahim

    2017-10-01

    This paper attempts to conceptualize Islamic spirituality in medical imaging that deals with the humanistic and technical dimensions. It begins with establishing an understanding concerning spirituality, an area that now accepted as part of patient-centred care. This is followed by discussions pertaining to Islamic spirituality, related to the practitioner, patient care and the practice. Possible avenues towards applying Islamic spirituality in medical imaging are proposed. It is hoped that the resultant harmonization between Islamic spirituality and the practice will trigger awareness and interests pertaining to the role of a Muslim practitioner in advocating and enhancing Islamic spirituality.

  8. Differentiation of prostatitis and prostate cancer using the Prostate Imaging-Reporting and Data System (PI-RADS).

    Science.gov (United States)

    Meier-Schroers, Michael; Kukuk, Guido; Wolter, Karsten; Decker, Georges; Fischer, Stefan; Marx, Christian; Traeber, Frank; Sprinkart, Alois Martin; Block, Wolfgang; Schild, Hans Heinz; Willinek, Winfried

    2016-07-01

    To determine if prostate cancer (PCa) and prostatitis can be differentiated by using PI-RADS. 3T MR images of 68 patients with 85 cancer suspicious lesions were analyzed. The findings were correlated with histopathology. T2w imaging (T2WI), diffusion weighted imaging (DWI), dynamic contrast enhancement (DCE), and MR-Spectroscopy (MRS) were acquired. Every lesion was given a single PI-RADS score for each parameter, as well as a sum score and a PI-RADS v2 score. Furthermore, T2-morphology, ADC-value, perfusion type, citrate/choline-level, and localization were evaluated. 44 of 85 lesions showed PCa (51.8%), 21 chronic prostatitis (24.7%), and 20 other benign tissue such as hyperplasia or fibromuscular tissue (23.5%). The single PI-RADS score for T2WI, DWI, DCE, as well as the aggregated score including and not including MRS, and the PI-RADS v2-score were all significantly higher for PCa than for prostatitis or other tissue (pprostatitis than for other tissue (p=0.029 and p=0.020), whereas the other parameters were not different. Prostatitis usually presented borderline pathological PI-RADS scores, showed restricted diffusion with ADC≥900mm(2)/s in 100% of cases, was more often indistinctly hypointense on T2WI (66.7%), and localized in the transitional zone (57.1%). An ADC≥900mm(2)/s achieved the highest predictive value for prostatitis (AUC=0.859). Prostatitis can be differentiated from PCa using PI-RADS, since all available parameters are more distinct in cases of cancer. However, there is significant overlap between prostatitis and other benign findings, thus PI-RADS is only suitable to a limited extent for the primary assessment of prostatitis. Restricted diffusion with ADC≥900mm(2)/s is believed to be a good indicator for prostatitis. MRS can help to distinguish between prostatitis and other tissue. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  9. Automatic Image Alignment and Stitching of Medical Images with Seam Blending

    OpenAIRE

    Abhinav Kumar; Raja Sekhar Bandaru; B Madhusudan Rao; Saket Kulkarni; Nilesh Ghatpande

    2010-01-01

    This paper proposes an algorithm which automatically aligns and stitches the component medical images (fluoroscopic) with varying degrees of overlap into a single composite image. The alignment method is based on similarity measure between the component images. As applied here the technique is intensity based rather than feature based. It works well in domains where feature based methods have difficulty, yet more robust than traditional correlation. Component images are stitched together usin...

  10. Prospects in radionuclide imaging of prostate cancer

    NARCIS (Netherlands)

    Lutje, Susanne; Boerman, Otto C.; van Rij, Catharina M.; Sedelaar, Michiel; Helfrich, Wijnand; Oyen, Wim J. G.; Mulders, Peter F. A.

    Prostate cancer is the most common malignancy in men in the Western world and represents a major health problem with substantial morbidity and mortality. Sensitivity and specificity of digital rectal examination (DRE) and evaluation of prostate specific antigen (PSA) are excellent methods for

  11. Multiparametric magnetic resonance imaging characteristics of prostate tuberculosis

    Energy Technology Data Exchange (ETDEWEB)

    Cheng, Yue; Huang, Lixiang; Zhang, Xiaodong; Ji, Qian; Shen, Wen [Dept. of Radiology, Tianjin First Central Hospital, Tianjin (China)

    2015-08-15

    To describe the multiparametric magnetic resonance imaging (MRI) appearance of prostate tuberculosis. Six patients with prostate tuberculosis were analyzed retrospectively. The mean age of the patients was 60.5 years (range, 48-67 years). The mean prostate specific antigen concentration was 6.62 ng/mL (range, 0.54-14.57 ng/mL). All patients underwent a multiparametric MRI examination. The histopathological results were obtained from biopsies in four men and from transurethral resection of the prostate in two men after the MRI examination. Nodular (33%, 2/6 patients) and diffuse lesions (67%, 4/6 patients) were seen on MRI. The nodular lesions were featured by extremely low signal intensity (similar to that of muscle) on T2-weighted imaging (T2WI). The T2WI signal intensity of the diffuse lesions was low but higher than that of muscle, which showed high signal intensity on diffusion weighted imaging and low signal intensity on an apparent diffusion coefficient map. MR spectroscopic imaging of this type showed a normal-like spectrum. Abscesses were found in one patient with the nodular type and in one with the diffuse type. The appearance of prostate tuberculosis on MRI can be separated into multiple nodular and diffuse types. Multiparametric MRI may offer useful information for diagnosing prostate tuberculosis.

  12. Interobserver variability of radiation therapists aligning to fiducial markers for prostate radiation therapy

    International Nuclear Information System (INIS)

    Deegan, Timothy; Owen, Rebecca; Holt, Tanya; Roberts, Lisa; Biggs, Jennifer; McCarthy, Alicia; Parfitt, Matthew; Fielding, Andrew

    2013-01-01

    As the use of fiducial markers (FMs) for the localisation of the prostate during external beam radiation therapy (EBRT) has become part of routine practice, radiation therapists (RTs) have become increasingly responsible for online image interpretation. The aim of this investigation was to quantify the limits of agreement (LoA) between RTs when localising to FMs with orthogonal kilovoltage (kV) imaging. Six patients receiving prostate EBRT utilising FMs were included in this study. Treatment localisation was performed using kV imaging prior to each fraction. Online stereoscopic assessment of FMs, performed by the treating RTs, was compared with the offline assessment by three RTs. Observer agreement was determined by pairwise Bland-Altman analysis. Stereoscopic analysis of 225 image pairs was performed online at the time of treatment, and offline by three RT observers. Eighteen pairwise Bland-Altman analyses were completed to assess the level of agreement between observers. Localisation by RTs was found to be within clinically acceptable 95% LoAs. Small differences between RTs, in both the online and offline setting, were found to be within clinically acceptable limits. RTs were able to make consistent and reliable judgements when matching FMs on planar kV imaging.

  13. Multimodal Image Alignment via Linear Mapping between Feature Modalities.

    Science.gov (United States)

    Jiang, Yanyun; Zheng, Yuanjie; Hou, Sujuan; Chang, Yuchou; Gee, James

    2017-01-01

    We propose a novel landmark matching based method for aligning multimodal images, which is accomplished uniquely by resolving a linear mapping between different feature modalities. This linear mapping results in a new measurement on similarity of images captured from different modalities. In addition, our method simultaneously solves this linear mapping and the landmark correspondences by minimizing a convex quadratic function. Our method can estimate complex image relationship between different modalities and nonlinear nonrigid spatial transformations even in the presence of heavy noise, as shown in our experiments carried out by using a variety of image modalities.

  14. Computed Tomography Imaging of the Topographical Anatomy of Canine Prostate

    International Nuclear Information System (INIS)

    Dimtrox, R.; Yonkova, P.; Vladova, D.; Kostov, D.

    2010-01-01

    AIM: To investigate the topographical anatomy of canine prostate gland by computed tomography (CT) for diagnostic imaging purposes. ÐœATERIAL AND METHODS: Seven clinically healthy mongrel male dogs at the age of 3−4 years and body weight of 10−15 kg were submitted to transverse computerized axial tomography (CAT) with cross section thickness of 5 mm. RESULTS: The CT image of canine prostate is visualized throughout the scans of the pelvis in the planes through the first sacral vertebra (S1) dorsally; the bodies of iliac bones laterally and cranially to the pelvic brim (ventrally). The body of prostate appears as an oval homogenous relatively hypo dense finding with soft tissue density. The gland is well differentiated from the adjacent soft tissues. CONCLUSION: By means of CT, the cranial part of prostate gland in adult dogs aged 3−4 years exhibited an abdominal localization. (author)

  15. A statistically harmonized alignment-classification in image space enables accurate and robust alignment of noisy images in single particle analysis.

    Science.gov (United States)

    Kawata, Masaaki; Sato, Chikara

    2007-06-01

    In determining the three-dimensional (3D) structure of macromolecular assemblies in single particle analysis, a large representative dataset of two-dimensional (2D) average images from huge number of raw images is a key for high resolution. Because alignments prior to averaging are computationally intensive, currently available multireference alignment (MRA) software does not survey every possible alignment. This leads to misaligned images, creating blurred averages and reducing the quality of the final 3D reconstruction. We present a new method, in which multireference alignment is harmonized with classification (multireference multiple alignment: MRMA). This method enables a statistical comparison of multiple alignment peaks, reflecting the similarities between each raw image and a set of reference images. Among the selected alignment candidates for each raw image, misaligned images are statistically excluded, based on the principle that aligned raw images of similar projections have a dense distribution around the correctly aligned coordinates in image space. This newly developed method was examined for accuracy and speed using model image sets with various signal-to-noise ratios, and with electron microscope images of the Transient Receptor Potential C3 and the sodium channel. In every data set, the newly developed method outperformed conventional methods in robustness against noise and in speed, creating 2D average images of higher quality. This statistically harmonized alignment-classification combination should greatly improve the quality of single particle analysis.

  16. Prostatic carcinoma. Diagnostic and stating: MR imaging. Cancer de la prostate Diagnostic et bilan: role de l'imagerie

    Energy Technology Data Exchange (ETDEWEB)

    Roy, C; Spittler, G; Jacqmin, D [Centre Hospitalier Universitaire, 67 - Strasbourg (FR); Morel, M [Clinique Saint-Francois, 67 Haguenau (FR)

    1991-01-01

    Prostatic carcinoma is the second most commun cause of cancer death over 60 years. It is suspected by digital examination and prostatic specific antigen dosage. Transrectal ultrasound shows the tumor as an hypoechoic lesion. Sensitivity is good but specificity is low. Transrectal biopsy of prostate guided by transrectal ultrasound made the diagnosis. At present, MR Imaging is the most accurate diagnostic modality for loco-regional staging of prostatic carcinoma.

  17. Poster - 10: QA of Ultrasound Images for Prostate Brachytherapy

    Energy Technology Data Exchange (ETDEWEB)

    Szpala, Stanislaw; Kohli, Kirpal S. [BCCA-Fraser Valley Centre (Canada)

    2016-08-15

    Purpose: The current QA protocol of ultrasound systems used in prostate brachytherapy (TG128) addresses geometrical verifications, but the scope of evaluation of image quality is limited. We recognized importance of the latter in routine practice, and designed a protocol for QA of the images. Methods: Images of an ultrasound prostate phantom (CIRS053) were collected with BK Flex Focus 400. The images were saved as bmp after adjusting the gain to 50% for consistent results. Mean pixel values and signal to noise ratio were inspected in the representative sections of the phantom, including the mock prostate and the unechoic medium. Constancy of these numbers over a one year period was looked at. Results: The typical intensity in the mock prostate region in the transverse images ranged between 95 and 118 (out of 256), and the signal to noise was about 10. The intensity in the urethra region was about 170±40, and the unechoic medium was 2±2. The mean and the signal to noise ratio remained almost unchanged after a year, while the signal in the unechoic medium increased to about 7±4. Similar values were obtained in the sagittal images. Conclusions: The image analysis discussed above allows quick evaluation of constancy of the image quality. This may be also useful in troubleshooting image-quality problems during routine exams, which might not be due to deterioration of the US system, but other reasons, e.g. variations in tissue properties or air being trapped between the probe and the anatomy.

  18. Intrafractional prostate motion during online image guided intensity-modulated radiotherapy for prostate cancer

    International Nuclear Information System (INIS)

    Budiharto, Tom; Slagmolen, Pieter; Haustermans, Karin; Maes, Frederik; Junius, Sara; Verstraete, Jan; Oyen, Raymond; Hermans, Jeroen; Van den Heuvel, Frank

    2011-01-01

    Introduction: Intrafractional motion consists of two components: (1) the movement between the on-line repositioning procedure and the treatment start and (2) the movement during the treatment delivery. The goal of this study is to estimate this intrafractional movement of the prostate during prostate cancer radiotherapy. Material and methods: Twenty-seven patients with prostate cancer and implanted fiducials underwent a marker match procedure before a five-field IMRT treatment. For all fields, in-treatment images were obtained and then processed to enable automatic marker detection. Combining the subsequent projection images, five positions of each marker were determined using the shortest path approach. The residual set-up error (RSE) after kV-MV based prostate localization, the prostate position as a function of time during a radiotherapy session and the required margins to account for intrafractional motion were determined. Results: The mean RSE and standard deviation in the antero-posterior, cranio-caudal and left-right direction were 2.3 ± 1.5 mm, 0.2 ± 1.1 mm and -0.1 ± 1.1 mm, respectively. Almost all motions occurred in the posterior direction before the first treatment beam as the percentage of excursions >5 mm was reduced significantly when the RSE was not accounted for. The required margins for intrafractional motion increased with prolongation of the treatment. Application of a repositioning protocol after every beam could decrease the 1 cm margin from CTV to PTV by 2 mm. Conclusions: The RSE is the main contributor to intrafractional motion. This RSE after on-line prostate localization and patient repositioning in the posterior direction emphasizes the need to speed up the marker match procedure. Also, a prostate IMRT treatment should be administered as fast as possible, to ensure that the pre-treatment repositioning efforts are not erased by intrafractional prostate motion. This warrants an optimized workflow with the use of faster treatment

  19. Compact Positron Tomograph for Prostate Imaging

    National Research Council Canada - National Science Library

    Derenzo, Stephen

    2003-01-01

    The goal of this project is to construct a functioning compact positron tomography, whose geometry is optimized for detecting prostate tumors with molecular tracers such as 11Ccholine (carbon-11 choline...

  20. Compact Positron Tomograph for Prostate Imaging

    National Research Council Canada - National Science Library

    Huber, Jennifer

    2004-01-01

    The goal of this project is to construct a functioning compact positron tomograph, whose geometry is optimized for detecting prostate tumors with molecular tracers such as 11Ccholine (carbon-11 choline...

  1. Compact Positron Tomograph for Prostate Imaging

    National Research Council Canada - National Science Library

    Huber, Jennifer S

    2005-01-01

    The goal of this project is to construct a functioning compact positron tomograph, whose geometry is optimized for detecting prostate tumors with molecular tracers such as 11Ccholine (carbon-11 choline...

  2. Image quality and cancer visibility of T2-weighted Magnetic Resonance Imaging of the prostate at 7 Tesla

    NARCIS (Netherlands)

    Vos, E.K.; Lagemaat, M.W.; Barentsz, J.O.; Futterer, J.J.; Zamecnik, P.; Roozen, H.; Orzada, S.; Bitz, A.K.; Maas, M.C.; Scheenen, T.W.J.

    2014-01-01

    To assess the image quality of T2-weighted (T2w) magnetic resonance imaging of the prostate and the visibility of prostate cancer at 7 Tesla (T).Seventeen prostate cancer patients underwent T2w imaging at 7T with only an external transmit/receive array coil. Three radiologists independently scored

  3. Image Guidance Based on Prostate Position for Prostate Cancer Proton Therapy

    International Nuclear Information System (INIS)

    Vargas, Carlos; Wagner, Marcus; Indelicato, Daniel; Fryer, Amber; Horne, David; Chellini, Angela; McKenzie, Craig; Lawlor, Paula; Mahajan, Chaitali; Li Zuofeng; Lin Liyong; Keole, Sameer

    2008-01-01

    Purpose: To determine the target coverage for proton therapy with and without image guidance and daily prebeam reorientation. Methods and Materials: A total of 207 prostate positions were analyzed for 9 prostate cancer patients treated using our low-risk prostate proton therapy protocol (University of Florida Proton Therapy Institute 001). The planning target volume was defined as the prostate plus a 5-mm axial and 8-mm superoinferior extension. The prostate was repositioned using 5- and 10-mm shifts (anteriorly, inferiorly, posteriorly, and superiorly) and for Points A-D using a combination of 10-mm multidimensional movements (anteriorly or inferiorly; posteriorly or superiorly; and left or right). The beams were then realigned using the new prostate position. The prescription dose was 78 Gray equivalent (GE) to 95% of the planning target volume. Results: For small movements in the anterior, inferior, and posterior directions within the planning target volume (≤5 mm), treatment realignment demonstrated small, but significant, improvements in the clinical target volume (CTV) coverage to the prescribed dose (78 GE). The anterior and posterior shifts also significantly increased the minimal CTV dose (Δ +1.59 GE). For prostate 10-mm movements in the inferior, posterior, and superior directions, the beam realignment produced larger and significant improvements for both the CTV V 78 (Δ +6.4%) and the CTV minimal dose (Δ +8.22 GE). For the compounded 10-mm multidimensional shifts, realignment significantly improved the CTV V 78 (Δ +11.8%) and CTV minimal dose (Δ +23.6 GE). After realignment, the CTV minimal dose was >76.6 GE (>98%) for all points (A-D). Conclusion: Proton beam realignment after target shift will enhance CTV coverage for different prostate positions

  4. Precision crystal alignment for high-resolution electron microscope imaging

    International Nuclear Information System (INIS)

    Wood, G.J.; Beeching, M.J.

    1990-01-01

    One of the more difficult tasks involved in obtaining quality high-resolution electron micrographs is the precise alignment of a specimen into the required zone. The current accepted procedure, which involves changing to diffraction mode and searching for symmetric point diffraction pattern, is insensitive to small amounts of misalignment and at best qualitative. On-line analysis of the fourier space representation of the image, both for determining and correcting crystal tilt, is investigated. 8 refs., 42 figs

  5. Nuclear medicine imaging of prostate cancer; Nuklearmedizinische Diagnostik des Prostatakarzinoms

    Energy Technology Data Exchange (ETDEWEB)

    Schreiter, V.; Reimann, C. [Charite Universitaetsmedizin Berlin (Germany). Dept. of Radiology; Schreiter, N.F. [Charite Universitaetsmedizin Berlin (Germany). Dept. of Nuclear Medicine; Geisel, D.

    2016-11-15

    The new tracer Gallium-68 prostate-specific membrane antigen (Ga-68 PSMA) yields new promising options for the PET/CT diagnosis of prostate cancer (PCa) and its metastases. To overcome limitations of hybrid imaging, known from the use of choline derivatives, seems to be possible with the use of Ga-68 PSMA for PCa. The benefits of hybrid imaging with Ga-68 PSMA for PCa compared to choline derivatives shall be discussed in this article based on an overview of the current literature.

  6. Biologically inspired EM image alignment and neural reconstruction.

    Science.gov (United States)

    Knowles-Barley, Seymour; Butcher, Nancy J; Meinertzhagen, Ian A; Armstrong, J Douglas

    2011-08-15

    Three-dimensional reconstruction of consecutive serial-section transmission electron microscopy (ssTEM) images of neural tissue currently requires many hours of manual tracing and annotation. Several computational techniques have already been applied to ssTEM images to facilitate 3D reconstruction and ease this burden. Here, we present an alternative computational approach for ssTEM image analysis. We have used biologically inspired receptive fields as a basis for a ridge detection algorithm to identify cell membranes, synaptic contacts and mitochondria. Detected line segments are used to improve alignment between consecutive images and we have joined small segments of membrane into cell surfaces using a dynamic programming algorithm similar to the Needleman-Wunsch and Smith-Waterman DNA sequence alignment procedures. A shortest path-based approach has been used to close edges and achieve image segmentation. Partial reconstructions were automatically generated and used as a basis for semi-automatic reconstruction of neural tissue. The accuracy of partial reconstructions was evaluated and 96% of membrane could be identified at the cost of 13% false positive detections. An open-source reference implementation is available in the Supplementary information. seymour.kb@ed.ac.uk; douglas.armstrong@ed.ac.uk Supplementary data are available at Bioinformatics online.

  7. Reduction of Dose Delivered to Organs at Risk in Prostate Cancer Patients via Image-Guided Radiation Therapy

    International Nuclear Information System (INIS)

    Pawlowski, Jason M.; Yang, Eddy S.; Malcolm, Arnold W.; Coffey, Charles W.; Ding, George X.

    2010-01-01

    Purpose: To determine whether image guidance can improve the dose delivered to target organs and organs at risk (OARs) for prostate cancer patients treated with intensity-modulated radiotherapy (IMRT). Methods and Materials: Eight prostate cancer patients were treated with IMRT to 76 Gy at 2 Gy per fraction. Daily target localization was performed via alignment of three intraprostatic fiducials and weekly kV-cone beam computed tomography (CBCT) scans. The prostate and OARs were manually contoured on each CBCT by a single physician. Daily patient setup shifts were obtained by comparing alignment of skin tattoos with the treatment position based on fiducials. Treatment fields were retrospectively applied to CBCT scans. The dose distributions were calculated using actual treatment plans (an 8-mm PTV margin everywhere except for 6-mm posteriorly) with and without image guidance shifts. Furthermore, the feasibility of margin reduction was evaluated by reducing planning margins to 4 mm everywhere except for 3 mm posteriorly. Results: For the eight treatment plans on the 56 CBCT scans, the average doses to 98% of the prostate (D98) were 102% (range, 99-104%) and 99% (range, 45-104%) with and without image guidance, respectively. Using margin reduction, the average D98s were 100% (range, 84-104%) and 92% (range, 40-104%) with and without image guidance, respectively. Conclusions: Currently, margins used in IMRT plans are adequate to deliver a dose to the prostate with conventional patient positioning using skin tattoos or bony anatomy. The use of image guidance may facilitate significant reduction of planning margins. Future studies to assess the efficacy of decreasing margins and improvement of treatment-related toxicities are warranted.

  8. Alignment effects on a neutron imaging system using coded apertures

    International Nuclear Information System (INIS)

    Thfoin, Isabelle; Landoas, Olivier; Caillaud, Tony; Vincent, Maxime; Bourgade, Jean-Luc; Rosse, Bertrand; Disdier, Laurent; Sangster, Thomas C.; Glebov, Vladimir Yu.; Pien, Greg; Armstrong, William

    2010-01-01

    A high resolution neutron imaging system is being developed and tested on the OMEGA laser facility for inertial confinement fusion experiments. This diagnostic uses a coded imaging technique with a penumbral or an annular aperture. The sensitiveness of these techniques to misalignment was pointed out with both experiments and simulations. Results obtained during OMEGA shots are in good agreement with calculations performed with the Monte Carlo code GEANT4. Both techniques are sensitive to the relative position of the source in the field of view. The penumbral imaging technique then demonstrates to be less sensitive to misalignment compared to the ring. These results show the necessity to develop a neutron imaging diagnostic for megajoule class lasers taking into account our alignment capabilities on such facilities.

  9. Evaluation of Tl-201 SPECT imaging findings in prostate cancer

    Directory of Open Access Journals (Sweden)

    Sinem Ozyurt

    2015-07-01

    Full Text Available Objectives: To compare with histopathological findings the findings of prostate cancer imaging by SPECT method using Tl-201 as a tumor seeking agent. Methods: The study comprised 59 patients (age range 51-79 years, mean age 65.3 ± 6.8 years who were planned to have transrectal ultrasonography (TRUS-guided biopsies due to suspicion of prostate cancer between April 2011 and September 2011. Early planar, late planar and SPECT images were obtained for all patients. Scintigraphic evaluation was made in relation to uptake presence and patterns in the visual assessment and to Tumor/Background (T/Bg ratios for both planar and SPECT images in the quantitative assessment. Histopathological findings were compatible with benign etiology in 36 (61% patients and malign etiology in 23 (39% patients. Additionally, comparisons were made to evaluate the relationships between uptake patterns,total PSA values and Gleason scores. Results: A statistically significant difference was found between the benign and malignant groups in terms of uptake in planar and SPECT images and T/Bg ratios and PSA values. No statistically significant difference was found between uptake patterns of planar and SPECT images and Gleason scores in the malignant group. Conclusions: SPECT images were superior to planar images in the comparative assessment. Tl-201 SPECT imaging can provide an additional contribution to clinical practice in the diagnosis of prostate cancer and it can be used in selected patients.

  10. Prostate Ultrasound

    Medline Plus

    Full Text Available ... ultrasound or with a rectal examination, an ultrasound-guided biopsy can be performed. This procedure involves advancing ... of the Prostate) Prostate Cancer Ultrasound- and MRI-Guided Prostate Biopsy Images related to Ultrasound - Prostate Sponsored ...

  11. Prostatitis

    Science.gov (United States)

    Prostatitis Overview Prostatitis is swelling and inflammation of the prostate gland, a walnut-sized gland situated directly below the bladder in ... produces fluid (semen) that nourishes and transports sperm. Prostatitis often causes painful or difficult urination. Other symptoms ...

  12. Detection of prostate cancer by contrast-ultrasound dispersion imaging

    NARCIS (Netherlands)

    Kuenen, M.P.J.; Saidov, T.A.; Heneweer, C.; Wijkstra, H.; Mischi, M.

    2013-01-01

    Despite the development of several efficient focal therapies for prostate cancer, treatment options are often restricted to radical treatments, such as a radical prostatectomy. One of the main obstacles preventing a wider application of focal therapies is the lack of reliable imaging methods for

  13. Nuclear Imaging of Prostate Cancer with Gastrin-Releasing-Peptide-Receptor Targeted Radiopharmaceuticals

    NARCIS (Netherlands)

    Ananias, H. J. K.; de Jong, I. J.; Dierckx, R. A.; van de Wiele, C.; Helfrich, W.; Elsinga, P. H.

    2008-01-01

    Prostate cancer is one of the most common causes of cancer in men. Evaluating the different stages of prostate cancer with conventional imaging techniques still proves difficult. Nuclear imaging might provide a technique that is able to evaluate prostate cancer, but clinical application has been

  14. MISTICA: Minimum Spanning Tree-Based Coarse Image Alignment for Microscopy Image Sequences.

    Science.gov (United States)

    Ray, Nilanjan; McArdle, Sara; Ley, Klaus; Acton, Scott T

    2016-11-01

    Registration of an in vivo microscopy image sequence is necessary in many significant studies, including studies of atherosclerosis in large arteries and the heart. Significant cardiac and respiratory motion of the living subject, occasional spells of focal plane changes, drift in the field of view, and long image sequences are the principal roadblocks. The first step in such a registration process is the removal of translational and rotational motion. Next, a deformable registration can be performed. The focus of our study here is to remove the translation and/or rigid body motion that we refer to here as coarse alignment. The existing techniques for coarse alignment are unable to accommodate long sequences often consisting of periods of poor quality images (as quantified by a suitable perceptual measure). Many existing methods require the user to select an anchor image to which other images are registered. We propose a novel method for coarse image sequence alignment based on minimum weighted spanning trees (MISTICA) that overcomes these difficulties. The principal idea behind MISTICA is to reorder the images in shorter sequences, to demote nonconforming or poor quality images in the registration process, and to mitigate the error propagation. The anchor image is selected automatically making MISTICA completely automated. MISTICA is computationally efficient. It has a single tuning parameter that determines graph width, which can also be eliminated by the way of additional computation. MISTICA outperforms existing alignment methods when applied to microscopy image sequences of mouse arteries.

  15. Fused-data transrectal EIT for prostate cancer imaging.

    Science.gov (United States)

    Murphy, Ethan K; Wu, Xiaotian; Halter, Ryan J

    2018-05-25

    Prostate cancer is a significant problem affecting 1 in 7 men. Unfortunately, the diagnostic gold-standard of ultrasound-guided biopsy misses 10%-30% of all cancers. The objective of this study was to develop an electrical impedance tomography (EIT) approach that has the potential to image the entire prostate using multiple impedance measurements recorded between electrodes integrated onto an end-fired transrectal ultrasound (TRUS) device and a biopsy probe (BP). Simulations and sensitivity analyses were used to investigate the best combination of electrodes, and measured tank experiments were used to evaluate a fused-data transrectal EIT (fd-TREIT) and BP approach. Simulations and sensitivity analysis revealed that (1) TREIT measurements are not sufficiently sensitive to image the whole prostate, (2) the combination of TREIT  +  BP measurements increases the sensitive region of TREIT-only measurements by 12×, and (3) the fusion of multiple TREIT  +  BP measurements collected during a routine or customized 12-core biopsy procedure can cover up to 76.1% or 94.1% of a nominal 50 cm 3 prostate, respectively. Three measured tank experiments of the fd-TREIT  +  BP approach successfully and accurately recovered the positions of 2-3 metal or plastic inclusions. The measured tank experiments represent important steps in the development of an algorithm that can combine EIT from multiple locations and from multiple probes-data that could be collected during a routine TRUS-guided 12-core biopsy. Overall, this result is a step towards a clinically deployable impedance imaging approach to scanning the entire prostate, which could significantly help to improve prostate cancer diagnosis.

  16. The use of gold markers and electronic portal imaging for radiotherapy verification in prostate cancer patients: Sweden Ghana Medical Centre experience

    Directory of Open Access Journals (Sweden)

    George Felix Acquah

    2014-02-01

    Full Text Available The success of radiotherapy cancer treatment delivery depends on the accuracy of patient setup for each fraction. A significant problem arises from reproducing the same patient position and prostate location during treatment planning for every fraction of the treatment process. To analyze the daily movements of the prostate, gold markers are implanted in the prostate and portal images taken and manually matched with reference images to locate the prostate. Geometrical and fiducial markers are annotated onto a highly quality generated digitally reconstructed radiographs, that are compared with portal images acquired right before treatment dose delivery. A 0 and 270 degree treatment fields are used to calculate prostate shifts for all prostate cancer patients undergoing treatment at the Sweden Ghana Medical Centre, using an iViewGT portal imaging device. After aligning of the marker positions onto the reference images, the set-up deviations corrections are displayed and an on-line correction procedure applied. The measured migrations of the prostate markers are below the threshold of 3 mm for the main plans and 2 mm for the boost plans. With daily electronic portal imaging combined with gold markers, provides an objective method for verifying and correcting the position of the prostate immediately prior to radiation delivery.--------------------------------------------Cite this article as: Acquah GF. The use of gold markers and electronic portal imaging for radiotherapy verification in prostate cancer patients: Sweden Ghana Medical Centre experience. Int J Cancer Ther Oncol 2014; 2(1:020112.DOI: http://dx.doi.org/10.14319/ijcto.0201.12

  17. Diffusion tensor imaging of the normal prostate at 3 Tesla

    International Nuclear Information System (INIS)

    Guerses, Bengi; Kabakci, Neslihan; Kovanlikaya, Arzu; Firat, Zeynep; Bayram, Ali; Kovanlikaya, Ilhami; Ulud, Aziz M.

    2008-01-01

    The aim of this study was to assess the feasibility of diffusion tensor imaging (DTI) of the prostate and to determine normative fractional anisotropy (FA) and apparent diffusion coefficient (ADC) values of healthy prostate with a 3-Tesla magnetic resonance imaging (MRI) system. Thirty volunteers with a mean age of 28 (25-35) years were scanned with a 3-Tesla MRI (Intera Achieva; Philips, The Netherlands) system using a six-channel phased array coil. Initially, T2-weighted turbo spin-echo (TSE) axial images of the prostate were obtained. In two subjects, a millimetric hypointense signal change was detected in the peripheral zones on T2-weighted TSE images. These two subjects were excluded from the study. DTI with single-shot echo-planar imaging (ssEPI) was performed in the remaining 28 subjects. ADC and FA values were measured using the manufacturer supplied software by positioning 9-pixel ROIs on each zone. Differences between parameters of the central and peripheral zones were assessed. Mean ADC value of the central (1.220 ± 0.271 x 10 -3 mm 2 /s) was found to be significantly lower when compared with the peripheral gland (1.610 ± 0.347 x 10 -3 mm 2 /s) (P < 0.01). Mean FA of the central gland was significantly higher (0.26), compared with the peripheral gland (0.16) (P < 0.01). This study shows the feasibility of prostate DTI with a 3-Tesla MR system and the normative FA and ADC values of peripheral and central zones of the normal prostate. The results are compatible with the microstructural organization of the gland. (orig.)

  18. Inverting Image Data For Optical Testing And Alignment

    Science.gov (United States)

    Shao, Michael; Redding, David; Yu, Jeffrey W.; Dumont, Philip J.

    1993-01-01

    Data from images produced by slightly incorrectly figured concave primary mirror in telescope processed into estimate of spherical aberration of mirror, by use of algorithm finding nonlinear least-squares best fit between actual images and synthetic images produced by multiparameter mathematical model of telescope optical system. Estimated spherical aberration, in turn, converted into estimate of deviation of reflector surface from nominal precise shape. Algorithm devised as part of effort to determine error in surface figure of primary mirror of Hubble space telescope, so corrective lens designed. Modified versions of algorithm also used to find optical errors in other components of telescope or of other optical systems, for purposes of testing, alignment, and/or correction.

  19. Imaging Cellular Proliferation in Prostate Cancer with Positron Emission Tomography

    Directory of Open Access Journals (Sweden)

    Hossein Jadvar

    2015-07-01

    Full Text Available Prostate cancer remains a major public health problem worldwide. Imaging plays an important role in the assessment of disease at all its clinical phases, including staging, restaging after definitive therapy, evaluation of therapy response, and prognostication. Positron emission tomography with a number of biologically targeted radiotracers has been demonstrated to have potential diagnostic and prognostic utility in the various clinical phases of this prevalent disease. Given the remarkable biological heterogeneity of prostate cancer, one major unmet clinical need that remains is the non-invasive imaging-based characterization of prostate tumors. Accurate tumor characterization allows for image-targeted biopsy and focal therapy as well as facilitates objective assessment of therapy effect. PET in conjunction with radiotracers that track the thymidine salvage pathway of DNA synthesis may be helpful to fulfill this necessity. We review briefly the preclinical and pilot clinical experience with the two major cellular proliferation radiotracers, [18F]-3’-deoxy-3’-fluorothymidine and [18F]-2’-fluoro-5-methyl-1-beta-D-arabinofuranosyluracil in prostate cancer.

  20. Transabdominal ultrasonography, computed tomography and electronic portal imaging for 3-dimensional conformal radiotherapy for prostate cancer

    International Nuclear Information System (INIS)

    Jereczek-Fossa, B.A.; Orecchia, R.; Cattani, F.; Garibaldi, C.; Cambria, R.; Valenti, M.; Ciocca, M.; Zerini, D.; Boboc, G.I.; Vavassori, A.; Ivaldi, G.B.; Kowalczyk, A.; Matei, D.V.; Cobelli, O. de

    2007-01-01

    Purpose: To evaluate the feasibility and accuracy of daily B-mode acquisition and targeting ultrasound-based prostate localization (BAT trademark) and to compare it with computed tomography (CT) and electronic portal imaging (EPI) in 3-dimensional conformal radiotherapy (3-D CRT) for prostate cancer. Patients and Methods: Ten patients were treated with 3-D CRT (72 Gy/30 fractions, 2.4 Gy/fraction, equivalent to 80 Gy/40 fractions, for α/β ratio of 1.5 Gy) and daily BAT-based prostate localization. For the first 5 fractions, CT and EPI were also performed in order to compare organ-motion and set-up error, respectively. Results: 287 BAT-, 50 CT- and 46 EPI-alignments were performed. The average BAT-determined misalignments in latero-lateral, antero-posterior and cranio-caudal directions were -0.9 mm ± 3.3 mm, 1.0 mm ± 4.0 mm and -0.9 mm ± 3.8 mm, respectively. The differences between BAT- and CT-determined organ-motion in latero-lateral, antero-posterior and cranio-caudal directions were 2.7 mm ± 1.9 mm, 3.9 ± 2.8 mm and 3.4 ± 3.0 mm, respectively. Weak correlation was found between BAT- and CT-determined misalignments in antero-posterior direction, while no correlation was observed in latero-lateral and cranio-caudal directions. The correlation was more significant when only data of good image-quality patients were analyzed (8 patients). Conclusion: BAT ensures the relative positions of target are the same during treatment and in treatment plan, however, the reliability of alignment is patient-dependent. The average BAT-determined misalignments were small, confirming the prevalence of random errors in 3-D CRT. Further study is warranted in order to establish the clinical value of BAT. (orig.)

  1. Value of Diffusion Tensor Imaging of Prostate Cancer: Comparison with Systemic Prostate Biopsy

    Energy Technology Data Exchange (ETDEWEB)

    Yoon, Seong Kuk; Kim, Dong Won; Ha, Dong Ho; Kwon, Hee Jin; Kang, Myong Jin; Choi, Sun Seob; Nam, Kyung Jin; Kim, Jung Il [Dong-A University, Medical Center, Busan (Korea, Republic of)

    2011-02-15

    This study was performed to evaluate the usefulness of diffusion tensor imaging (DTI) and to correlate systemic twelve biopsy in prostate cancer. Thirty-one patients with suspected prostate cancer underwent MR imaging. DTI was performed prior to a prostate biopsy. We prospectively calculated the apparent diffusion coefficient (ADC) and fractional anisotropy (FA) value in each corresponding biopsy site. Twenty-three of 31 patients had histopathologically proven adenocarcinoma. Among the 276 biopsy cores of 23 patients with prostate cancer, 109 cores showed positive results (39%). The ADC and FA value of positive cores were 1.31 {+-} 0.34x10-3 mm2/s and 0.68 {+-} 0.07, and those of the negative cores were 1.74 {+-} 0.45x10-3 mm2/s and 0.54 {+-} 0.09, respectively. Eight patients without carcinoma showed an ADC value of 1.83 {+-} 0.26x10-3 mm2/s and an FA value of 0.47 {+-} 0.07. The ADC and FA value of positive cores were significantly lower and higher than those of negative cores and cancer-free patients, respectively (p < 0.05). The ADC and FA values using DTI may provide useful diagnostic information in the differentiation of cancerous tissues, although there is overlap in some cases

  2. Correlation of breast image alignment using biomechanical modelling

    Science.gov (United States)

    Lee, Angela; Rajagopal, Vijay; Bier, Peter; Nielsen, Poul M. F.; Nash, Martyn P.

    2009-02-01

    Breast cancer is one of the most common causes of cancer death among women around the world. Researchers have found that a combination of imaging modalities (such as x-ray mammography, magnetic resonance, and ultrasound) leads to more effective diagnosis and management of breast cancers because each imaging modality displays different information about the breast tissues. In order to aid clinicians in interpreting the breast images from different modalities, we have developed a computational framework for generating individual-specific, 3D, finite element (FE) models of the breast. Medical images are embedded into this model, which is subsequently used to simulate the large deformations that the breasts undergo during different imaging procedures, thus warping the medical images to the deformed views of the breast in the different modalities. In this way, medical images of the breast taken in different geometric configurations (compression, gravity, etc.) can be aligned according to physically feasible transformations. In order to analyse the accuracy of the biomechanical model predictions, squared normalised cross correlation (NCC2) was used to provide both local and global comparisons of the model-warped images with clinical images of the breast subject to different gravity loaded states. The local comparison results were helpful in indicating the areas for improvement in the biomechanical model. To improve the modelling accuracy, we will need to investigate the incorporation of breast tissue heterogeneity into the model and altering the boundary conditions for the breast model. A biomechanical image registration tool of this kind will help radiologists to provide more reliable diagnosis and localisation of breast cancer.

  3. Impact of Image Guidance on Outcomes After External Beam Radiotherapy for Localized Prostate Cancer

    International Nuclear Information System (INIS)

    Kupelian, Patrick A.; Willoughby, Twyla R.; Reddy, Chandana A.; Klein, Eric A.; Mahadevan, Arul

    2008-01-01

    Purpose: To verify whether rectal distention at the time of planning impacts outcomes in patients with localized prostate cancer treated with daily image guidance. Methods and Materials: Between 1998 and 2002, a total of 488 prostate cancer patients were treated with intensity-modulated radiotherapy. The radiation dose was 70 Gy delivered at 2.5 Gy per fraction in all cases. All cases were treated with a 4-mm margin posteriorly. In all cases the total rectal volume documented on the CT scan was used for treatment planning. No special bowel preparation instructions were given, either for the simulation or the daily treatments. Before each daily treatment, alignment of the prostate was performed with the B-mode acquisition and targeting (BAT) transabdominal ultrasound system. The median follow-up for all 488 patients was 60 months (range, 24-96 months). Results: For all patients the biochemical relapse-free survival (bRFS) rate at 5 years was 86%. The 5-year bRFS rate for the rectal distention 3 , 50 to 3 , and ≥100 cm 3 groups was 90%, 83%, and 85%, respectively (p = 0.18). To adjust for other potential variables affecting bRFS rates, a multivariate time-to-failure analysis using the Cox proportional hazards model was performed. Rectal distention was not an independent predictor of biochemical failure on multivariate analysis (p = 0.80). Rectal distention was not a predictor of rectal or urinary toxicity. Conclusion: The use of daily image guidance eliminates errors such as rectal distention at the initial planning stage that can affect outcomes after radiotherapy for localized prostate cancer

  4. Thermoacoustic imaging of prostate cancer: comparison to histology

    Science.gov (United States)

    Patch, S. K.; Griep, S. K.; Jacobsohn, K.; See, W. A.; Hull, D.

    2014-03-01

    Ex vivo imaging of fresh prostate specimens was performed to test the hypothesis that the thermoacoustic (TA) contrast mechanism generated with very high frequency electromagnetic (EM) irradiation is sensitive to prostate cancer. Ex vivo imaging was performed immediately after radical prostatectomy, performed as part of normal care. Irradiation pulsewidth was 700 ns and duty cycle was extremely low. Typical specific absorption rate (SAR) throughout the prostate was 70-90 kW/kg during pulsing, but time-averaged SAR was below 2 W/kg. TA pressure pulses generated by rapid heating due to EM energy deposition were detected using single element transducers. 15g/L glycine powder mixed into DI water served as acoustic couplant, which was chilled to prevent autolysis. Spatial encoding was performed by scanning in tomographic "step-and-shoot" mode, with 3 mm translation between slices and 1.8-degree rotation between tomographic views. Histology slides for 3 cases scanned with 2.25 MHz transducers were marked for comparison to TA reconstructions. These three cases showed little, moderate, and severe involvement in the histology levels surrounding the verumontanum. TA signal strength decreased with percent cancerous involvement. When VHF is used for tissue heating, the TA contrast mechanism is driven by ionic content and we observed suppressed TA signal from diseased prostate tissue in the peripheral zone. For the 45 regions of interest analyzed, a reconstruction value of 0.4 mV provides 100% sensitivity but only 29% specificity.

  5. MO-B-BRC-00: Prostate HDR Treatment Planning - Considering Different Imaging Modalities

    International Nuclear Information System (INIS)

    2016-01-01

    Brachytherapy has proven to be an effective treatment option for prostate cancer. Initially, prostate brachytherapy was delivered through permanently implanted low dose rate (LDR) radioactive sources; however, high dose rate (HDR) temporary brachytherapy for prostate cancer is gaining popularity. Needle insertion during prostate brachytherapy is most commonly performed under ultrasound (U/S) guidance; however, treatment planning may be performed utilizing several imaging modalities either in an intra- or post-operative setting. During intra-operative prostate HDR, the needles are imaged during implantation, and planning may be performed in real time. At present, the most common imaging modality utilized for intra-operative prostate HDR is U/S. Alternatively, in the post-operative setting, following needle implantation, patients may be simulated with computed tomography (CT) or magnetic resonance imaging (MRI). Each imaging modality and workflow provides its share of benefits and limitations. Prostate HDR has been adopted in a number of cancer centers across the nation. In this educational session, we will explore the role of U/S, CT, and MRI in HDR prostate brachytherapy. Example workflows and operational details will be shared, and we will discuss how to establish a prostate HDR program in a clinical setting. Learning Objectives: Review prostate HDR techniques based on the imaging modality Discuss the challenges and pitfalls introduced by the three imagebased options for prostate HDR brachytherapy Review the QA process and learn about the development of clinical workflows for these imaging options at different institutions

  6. MO-B-BRC-00: Prostate HDR Treatment Planning - Considering Different Imaging Modalities

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2016-06-15

    Brachytherapy has proven to be an effective treatment option for prostate cancer. Initially, prostate brachytherapy was delivered through permanently implanted low dose rate (LDR) radioactive sources; however, high dose rate (HDR) temporary brachytherapy for prostate cancer is gaining popularity. Needle insertion during prostate brachytherapy is most commonly performed under ultrasound (U/S) guidance; however, treatment planning may be performed utilizing several imaging modalities either in an intra- or post-operative setting. During intra-operative prostate HDR, the needles are imaged during implantation, and planning may be performed in real time. At present, the most common imaging modality utilized for intra-operative prostate HDR is U/S. Alternatively, in the post-operative setting, following needle implantation, patients may be simulated with computed tomography (CT) or magnetic resonance imaging (MRI). Each imaging modality and workflow provides its share of benefits and limitations. Prostate HDR has been adopted in a number of cancer centers across the nation. In this educational session, we will explore the role of U/S, CT, and MRI in HDR prostate brachytherapy. Example workflows and operational details will be shared, and we will discuss how to establish a prostate HDR program in a clinical setting. Learning Objectives: Review prostate HDR techniques based on the imaging modality Discuss the challenges and pitfalls introduced by the three imagebased options for prostate HDR brachytherapy Review the QA process and learn about the development of clinical workflows for these imaging options at different institutions.

  7. Automatic multimodal real-time tracking for image plane alignment in interventional Magnetic Resonance Imaging

    International Nuclear Information System (INIS)

    Neumann, Markus

    2014-01-01

    Interventional magnetic resonance imaging (MRI) aims at performing minimally invasive percutaneous interventions, such as tumor ablations and biopsies, under MRI guidance. During such interventions, the acquired MR image planes are typically aligned to the surgical instrument (needle) axis and to surrounding anatomical structures of interest in order to efficiently monitor the advancement in real-time of the instrument inside the patient's body. Object tracking inside the MRI is expected to facilitate and accelerate MR-guided interventions by allowing to automatically align the image planes to the surgical instrument. In this PhD thesis, an image-based work-flow is proposed and refined for automatic image plane alignment. An automatic tracking work-flow was developed, performing detection and tracking of a passive marker directly in clinical real-time images. This tracking work-flow is designed for fully automated image plane alignment, with minimization of tracking-dedicated time. Its main drawback is its inherent dependence on the slow clinical MRI update rate. First, the addition of motion estimation and prediction with a Kalman filter was investigated and improved the work-flow tracking performance. Second, a complementary optical sensor was used for multi-sensor tracking in order to decouple the tracking update rate from the MR image acquisition rate. Performance of the work-flow was evaluated with both computer simulations and experiments using an MR compatible test bed. Results show a high robustness of the multi-sensor tracking approach for dynamic image plane alignment, due to the combination of the individual strengths of each sensor. (author)

  8. An improved image alignment procedure for high-resolution transmission electron microscopy.

    Science.gov (United States)

    Lin, Fang; Liu, Yan; Zhong, Xiaoyan; Chen, Jianghua

    2010-06-01

    Image alignment is essential for image processing methods such as through-focus exit-wavefunction reconstruction and image averaging in high-resolution transmission electron microscopy. Relative image displacements exist in any experimentally recorded image series due to the specimen drifts and image shifts, hence image alignment for correcting the image displacements has to be done prior to any further image processing. The image displacement between two successive images is determined by the correlation function of the two relatively shifted images. Here it is shown that more accurate image alignment can be achieved by using an appropriate aperture to filter the high-frequency components of the images being aligned, especially for a crystalline specimen with little non-periodic information. For the image series of crystalline specimens with little amorphous, the radius of the filter aperture should be as small as possible, so long as it covers the innermost lattice reflections. Testing with an experimental through-focus series of Si[110] images, the accuracies of image alignment with different correlation functions are compared with respect to the error functions in through-focus exit-wavefunction reconstruction based on the maximum-likelihood method. Testing with image averaging over noisy experimental images from graphene and carbon-nanotube samples, clear and sharp crystal lattice fringes are recovered after applying optimal image alignment. Copyright 2010 Elsevier Ltd. All rights reserved.

  9. SU-D-210-07: The Dependence On Acoustic Velocity of Medium On the Needle Template and Electronic Grid Alignment in Ultrasound QA for Prostate Brachytherapy

    Energy Technology Data Exchange (ETDEWEB)

    Kapoor, P; Kapoor, R; Curran, B [Virginia Commonwealth University, Richmond, VA (United States); HH McGuire VA Hospital, Richmond, VA (United States)

    2015-06-15

    Purpose: To analyze the impact on acoustic velocity (AV) of two different media (water and milk) using the needle template/electronic grid alignment test. Water, easily available, makes a good material to test the alignment of the template and grid although water’s AV (1498 m/s at 25°C) is significantly different from tissue (1540 m/s). Milk, with an AV much closer (1548 m/s) to prostate tissue, may be a good substitute for water in ultrasound quality assurance testing. Methods: Tests were performed using a Hitachi ultrasound unit with a mechanical arrangement designed to position needles parallel to the transducer. In this work, two materials – distilled water and homogenized whole milk (AVs of 1498 and 1548 m/s at 25°C) were used in a phantom to test ultrasound needle/grid alignment. The images were obtained with both materials and analyzed for their placement accuracy. Results: The needle template/electronic grid alignment tests showed displacement errors between measured and calculated values. The measurements showed displacements of 2.3mm (water) and 0.4mm (milk), and 1.6mm (water) and 0.3mm (milk) at depths of 7cm and 5cm respectively from true needle positions. The calculated results showed a displacement of 2.36 mm (water); 0.435mm (milk), and 1.66mm (water) and 0.31mm (milk) at a depth of 7cm and 5cm respectively. The displacements in the X and Y directions were also calculated. At depths of 7cm and 5cm, the (ΔX,ΔY) displacements in water were (0.829mm, 2.21mm) and (0.273mm, 1.634mm) and for milk were (0.15mm, 0.44mm) and (0.05mm, 0.302mm) respectively. Conclusion: The measured and calculated values were in good agreement for all tests. They show that milk provides superior results when performing needle template and electronic grid alignment tests for ultrasound units used in prostate brachytherapy.

  10. Fabrication of Aligned Nanofibers by Manipulated Rotating Drum Method and Studying the Effective Parameters on Fibers Alignment by Image Processing

    Directory of Open Access Journals (Sweden)

    Zohreh Hadi

    2013-01-01

    Full Text Available Electrospinning is a known process to produce nanofibers through electrostatic forces. In a typical process, an electrical potential is applied between droplets of polymer solution or melt, held through a syringe needle and a grounded target. In general electrospinning fibers are collected on the grounded target as a random oriented web of nanofiber. Various research projects are attempted to obtain aligned electrospun fibers. This modified electrospinning method can be developed and used in a variety of nanofiber-based applications such as making of nanofibrous scaffolds for tissue engineering. In this study, an effective method has been developed to fabricate aligned nanofibers by manipulation of electrospinning system using two nozzles with opposite charges. Moreover, the effect of some parameters including take-up velocity, applied voltage and polymer solution concentration on alignment of produced nanofibers is investigated. The comparison of fibers alignment was carried out by programming and image processing in MATLAB. It is shown that take-up velocity and polymer solution concentration have significant effect on increasing the fibers alignment. Also, the alignment is increased with applied voltage at first and then, it is decreased. The analytical results and optical microscopic images are clear evidence of showing the maximum alignment of nanofibers obtained at 15% polymer solution concentration with take-up velocity of 600 rpm and 11 kV voltage.

  11. A Review of Imaging Methods for Prostate Cancer Detection

    Directory of Open Access Journals (Sweden)

    Saradwata Sarkar

    2016-01-01

    Full Text Available Imaging is playing an increasingly important role in the detection of prostate cancer (PCa. This review summarizes the key imaging modalities–multiparametric ultrasound (US, multiparametric magnetic resonance imaging (MRI, MRI-US fusion imaging, and positron emission tomography (PET imaging–-used in the diagnosis and localization of PCa. Emphasis is laid on the biological and functional characteristics of tumors that rationalize the use of a specific imaging technique. Changes to anatomical architecture of tissue can be detected by anatomical grayscale US and T2-weighted MRI. Tumors are known to progress through angiogenesis–-a fact exploited by Doppler and contrast-enhanced US and dynamic contrast-enhanced MRI. The increased cellular density of tumors is targeted by elastography and diffusion-weighted MRI. PET imaging employs several different radionuclides to target the metabolic and cellular activities during tumor growth. Results from studies using these various imaging techniques are discussed and compared.

  12. Molecular Imaging and Precision Medicine in Prostate Cancer.

    Science.gov (United States)

    Ceci, Francesco; Fiorentino, Michelangelo; Castellucci, Paolo; Fanti, Stefano

    2017-01-01

    The aim of the present review is to discuss about the role of new probes for molecular imaging in the evaluation of prostate cancer (PCa). This review focuses particularly on the role of new promising radiotracers for the molecular imaging with PET/computed tomography in the detection of PCa recurrence. The role of these new imaging techniques to guide lesion-target therapies and the potential application of these molecular probes as theranostics agents is discussed. Finally, the molecular mechanisms underlying resistance to castration in PCa and the maintenance of active androgen receptor are discussed. Copyright © 2016 Elsevier Inc. All rights reserved.

  13. Prostate Ultrasound

    Medline Plus

    Full Text Available ... Physician Resources Professions Site Index A-Z Ultrasound - Prostate Ultrasound of the prostate uses sound waves to ... Ultrasound Imaging? What is Ultrasound Imaging of the Prostate? Ultrasound is safe and painless, and produces pictures ...

  14. The development of a compact positron tomograph for prostate imaging

    Energy Technology Data Exchange (ETDEWEB)

    Huber, Jennifer S.; Qi, Jinyi; Derenzo, Stephen E.; Moses, William W.; Huesman, Ronald H.; Budinger, Thomas F.

    2002-12-17

    We give design details and expected image results of a compact positron tomograph designed for prostate imaging that centers a patient between a pair of external curved detector banks (ellipse: 45 cm minor, 70 cm major axis). The bottom bank is fixed below the patient bed, and the top bank moves upward for patient access and downward for maximum sensitivity. Each bank is composed of two rows (axially) of 20 CTI PET Systems HR+ block detectors, forming two arcs that can be tilted to minimize attenuation. Compared to a conventional PET system, our camera uses about one-quarter the number of detectors and has almost two times higher solid angle coverage for a central point source, because the detectors are close to the patient. The detectors are read out by modified CTI HRRT data acquisition electronics. The individual detectors are angled in the plane to point towards the prostate to minimize reso

  15. Prostate Activated Prodrugs and Imaging Agents

    National Research Council Canada - National Science Library

    Jones, Graham B

    2004-01-01

    .... The substrate chosen was a 3 component system composed of a peptide sequence with affinity for PSA, an imaging agent and a deactivating bridge-linker, which electronically incapacitates the imaging agent...

  16. Dedicated mobile high resolution prostate PET imager with an insertable transrectal probe

    Science.gov (United States)

    Majewski, Stanislaw; Proffitt, James

    2010-12-28

    A dedicated mobile PET imaging system to image the prostate and surrounding organs. The imaging system includes an outside high resolution PET imager placed close to the patient's torso and an insertable and compact transrectal probe that is placed in close proximity to the prostate and operates in conjunction with the outside imager. The two detector systems are spatially co-registered to each other. The outside imager is mounted on an open rotating gantry to provide torso-wide 3D images of the prostate and surrounding tissue and organs. The insertable probe provides closer imaging, high sensitivity, and very high resolution predominately 2D view of the prostate and immediate surroundings. The probe is operated in conjunction with the outside imager and a fast data acquisition system to provide very high resolution reconstruction of the prostate and surrounding tissue and organs.

  17. Can Images Obtained With High Field Strength Magnetic Resonance Imaging Reduce Contouring Variability of the Prostate?

    International Nuclear Information System (INIS)

    Usmani, Nawaid; Sloboda, Ron; Kamal, Wafa; Ghosh, Sunita; Pervez, Nadeem; Pedersen, John; Yee, Don; Danielson, Brita; Murtha, Albert; Amanie, John; Monajemi, Tara

    2011-01-01

    Purpose: The objective of this study is to determine whether there is less contouring variability of the prostate using higher-strength magnetic resonance images (MRI) compared with standard MRI and computed tomography (CT). Methods and Materials: Forty patients treated with prostate brachytherapy were accrued to a prospective study that included the acquisition of 1.5-T MR and CT images at specified time points. A subset of 10 patients had additional 3.0-T MR images acquired at the same time as their 1.5-T MR scans. Images from each of these patients were contoured by 5 radiation oncologists, with a random subset of patients repeated to quantify intraobserver contouring variability. To minimize bias in contouring the prostate, the image sets were placed in folders in a random order with all identifiers removed from the images. Results: Although there was less interobserver contouring variability in the overall prostate volumes in 1.5-T MRI compared with 3.0-T MRI (p < 0.01), there was no significant differences in contouring variability in the different regions of the prostate between 1.5-T MRI and 3.0-T MRI. MRI demonstrated significantly less interobserver contouring variability in both 1.5-T and 3.0-T compared with CT in overall prostate volumes (p < 0.01, p = 0.01), with the greatest benefits being appreciated in the base of the prostate. Overall, there was less intraobserver contouring variability than interobserver contouring variability for all of the measurements analyzed. Conclusions: Use of 3.0-T MRI does not demonstrate a significant improvement in contouring variability compared with 1.5-T MRI, although both magnetic strengths demonstrated less contouring variability compared with CT.

  18. MR imaging of noncancerous lesions of the prostate gland

    International Nuclear Information System (INIS)

    Lovett, K.; Rifkin, M.D.; Choi, H.Y.; McCue, P.; Mitchell, D.G.; Burk, D.L. Jr.

    1990-01-01

    This paper determines the importance of MR signal characteristics in noncancerous lesions of the prostate. Step-sectioned radical prostatectomy specimens from over 50 individuals with stage A or B cancer were retrospectively reviewed and compared with correlative axial T2-weighted MR images obtained just prior to surgery. Noncancerous lesions were evaluated for signal intensity and location. Focal high-signal-intensity areas were present in 82% of patients. The 28% of lesions in the central gland correlated with cystic atrophy. Of the lesions in the peripheral prostate, 85% were cystic atrophy without associated cancer, 7.5% cystic atrophy with cancer, and 7.5% focal inflammation. Focal low-signal-intensity areas were present in 76% of patients. Of the 31% in the central prostate, one-fifth correlated with benign prostatic hyperplasia (BPH) and four-fifths with fibrous tissue, 10% to the 69% that were peripheral, 82% corresponded to fibrous tissue, 10% to BPH, and 8% to normal tissue. Mixed lesions were present in 73%; 93% of these were located centrally and 7% peripherally. All mixed central lesions were BPH, and the peripheral 7% were areas of combined cystic atrophy and fibrosis

  19. Initial results of a positron tomograph for prostate imaging

    Energy Technology Data Exchange (ETDEWEB)

    Huber, J.S.; Choong, W.S.; Moses, W.W.; Qi, J.; Hu, J.; Wang,G.C.; Wilson, D.; Oh, S.; Huesman, R.H.; Derenzo, S.E.; Budinger, T.F.

    2004-11-29

    We present the status and initial images of a positrontomograph for prostate imaging that centers a patient between a pair ofexternal curved detector banks (ellipse: 45 cm minor, 70 cm major axis).The distance between detector banks adjusts to allow patient access andto position the detectors as closely as possible for maximum sensitivitywith patients of various sizes. Each bank is composed of two axial rowsof 20 CTI PET Systems HR+ block detectors for a total of 80 modules inthe camera. Compared to an ECAT HR PET system operating in 3D mode, ourcamera uses about one-quarter the number of detectors and hasapproximately the same sensitivity for a central point source, becauseour detectors are close to the patient. The individual detectors areangled in the plane to point towards the prostate to minimize resolutiondegradation in that region. The detectors are read out by modified CTIdata acquisition electronics. We have completed construction of thegantry and electronics, have developed detector calibration and dataacquisition software, and are taking coincidence data. We demonstratethat we can clearly visualize a "prostate" in a simple phantom.Reconstructed images of two phantoms are shown.

  20. Differentiation of prostate cancer from benign prostate hypertrophy using dual-echo dynamic contrast MR imaging

    International Nuclear Information System (INIS)

    Muramoto, Satoshi; Uematsu, Hidemasa; Kimura, Hirohiko; Ishimori, Yoshiyuki; Sadato, Norihiro; Oyama, Nobuyuki; Matsuda, Tsuyoshi; Kawamura, Yasutaka; Yonekura, Yoshiharu; Okada, Kenichiro; Itoh, Harumi

    2002-01-01

    Objective: To investigate the usefulness of dynamic contrast magnetic resonance (MR) imaging in the differentiation of prostate cancer (PC) from benign prostate hypertrophy (BPH). Materials and methods: Eleven PC patients and 13 BPH patients were entered into the analysis. The mean gradient (MG) was calculated from the T2* term-eliminated time-signal intensity curve obtained from dynamic contrast MR data, and the MG of PC and that of BPH were compared. Results: The MG of PC was significantly higher than that of BPH. When the threshold value was set to 1.88% per s for discriminating PC from BPH, the sensitivity, specificity, and accuracy were 100, 85, and 92%, respectively. Conclusion: The MG, which is derived from the T2* term-eliminated time-signal intensity curve, may be a useful index for differentiating PC from BPH

  1. Method comparison of ultrasound and kilovoltage x-ray fiducial marker imaging for prostate radiotherapy targeting

    International Nuclear Information System (INIS)

    Fuller, Clifton David; Jr, Charles R Thomas; Schwartz, Scott; Golden, Nanalei; Ting, Joe; Wong, Adrian; Erdogmus, Deniz; Scarbrough, Todd J

    2006-01-01

    Several measurement techniques have been developed to address the capability for target volume reduction via target localization in image-guided radiotherapy; among these have been ultrasound (US) and fiducial marker (FM) software-assisted localization. In order to assess interchangeability between methods, US and FM localization were compared using established techniques for determination of agreement between measurement methods when a 'gold-standard' comparator does not exist, after performing both techniques daily on a sequential series of patients. At least 3 days prior to CT simulation, four gold seeds were placed within the prostate. FM software-assisted localization utilized the ExacTrac X-Ray 6D (BrainLab AG, Germany) kVp x-ray image acquisition system to determine prostate position; US prostate targeting was performed on each patient using the SonArray (Varian, Palo Alto, CA). Patients were aligned daily using laser alignment of skin marks. Directional shifts were then calculated by each respective system in the X, Y and Z dimensions before each daily treatment fraction, previous to any treatment or couch adjustment, as well as a composite vector of displacement. Directional shift agreement in each axis was compared using Altman-Bland limits of agreement, Lin's concordance coefficient with Partik's grading schema, and Deming orthogonal bias-weighted correlation methodology. 1019 software-assisted shifts were suggested by US and FM in 39 patients. The 95% limits of agreement in X, Y and Z axes were ±9.4 mm, ±11.3 mm and ±13.4, respectively. Three-dimensionally, measurements agreed within 13.4 mm in 95% of all paired measures. In all axes, concordance was graded as 'poor' or 'unacceptable'. Deming regression detected proportional bias in both directional axes and three-dimensional vectors. Our data suggest substantial differences between US and FM image-guided measures and subsequent suggested directional shifts. Analysis reveals that the vast majority of

  2. Oriented Edge-Based Feature Descriptor for Multi-Sensor Image Alignment and Enhancement

    Directory of Open Access Journals (Sweden)

    Myung-Ho Ju

    2013-10-01

    Full Text Available In this paper, we present an efficient image alignment and enhancement method for multi-sensor images. The shape of the object captured in a multi-sensor images can be determined by comparing variability of contrast using corresponding edges across multi-sensor image. Using this cue, we construct a robust feature descriptor based on the magnitudes of the oriented edges. Our proposed method enables fast image alignment by identifying matching features in multi-sensor images. We enhance the aligned multi-sensor images through the fusion of the salient regions from each image. The results of stitching the multi-sensor images and their enhancement demonstrate that our proposed method can align and enhance multi-sensor images more efficiently than previous methods.

  3. Image alignment for tomography reconstruction from synchrotron X-ray microscopic images.

    Directory of Open Access Journals (Sweden)

    Chang-Chieh Cheng

    Full Text Available A synchrotron X-ray microscope is a powerful imaging apparatus for taking high-resolution and high-contrast X-ray images of nanoscale objects. A sufficient number of X-ray projection images from different angles is required for constructing 3D volume images of an object. Because a synchrotron light source is immobile, a rotational object holder is required for tomography. At a resolution of 10 nm per pixel, the vibration of the holder caused by rotating the object cannot be disregarded if tomographic images are to be reconstructed accurately. This paper presents a computer method to compensate for the vibration of the rotational holder by aligning neighboring X-ray images. This alignment process involves two steps. The first step is to match the "projected feature points" in the sequence of images. The matched projected feature points in the x-θ plane should form a set of sine-shaped loci. The second step is to fit the loci to a set of sine waves to compute the parameters required for alignment. The experimental results show that the proposed method outperforms two previously proposed methods, Xradia and SPIDER. The developed software system can be downloaded from the URL, http://www.cs.nctu.edu.tw/~chengchc/SCTA or http://goo.gl/s4AMx.

  4. Image alignment for tomography reconstruction from synchrotron X-ray microscopic images.

    Science.gov (United States)

    Cheng, Chang-Chieh; Chien, Chia-Chi; Chen, Hsiang-Hsin; Hwu, Yeukuang; Ching, Yu-Tai

    2014-01-01

    A synchrotron X-ray microscope is a powerful imaging apparatus for taking high-resolution and high-contrast X-ray images of nanoscale objects. A sufficient number of X-ray projection images from different angles is required for constructing 3D volume images of an object. Because a synchrotron light source is immobile, a rotational object holder is required for tomography. At a resolution of 10 nm per pixel, the vibration of the holder caused by rotating the object cannot be disregarded if tomographic images are to be reconstructed accurately. This paper presents a computer method to compensate for the vibration of the rotational holder by aligning neighboring X-ray images. This alignment process involves two steps. The first step is to match the "projected feature points" in the sequence of images. The matched projected feature points in the x-θ plane should form a set of sine-shaped loci. The second step is to fit the loci to a set of sine waves to compute the parameters required for alignment. The experimental results show that the proposed method outperforms two previously proposed methods, Xradia and SPIDER. The developed software system can be downloaded from the URL, http://www.cs.nctu.edu.tw/~chengchc/SCTA or http://goo.gl/s4AMx.

  5. Automatic localization of the prostate for on-line or off-line image-guided radiotherapy

    International Nuclear Information System (INIS)

    Smitsmans, Monique H.P.; Wolthaus, Jochem W.H.; Artignan, Xavier; Bois, Josien de; Jaffray, David A.; Lebesque, Joos V.; Herk, Marcel van

    2004-01-01

    Purpose: With higher radiation dose, higher cure rates have been reported in prostate cancer patients. The extra margin needed to account for prostate motion, however, limits the level of dose escalation, because of the presence of surrounding organs at risk. Knowledge of the precise position of the prostate would allow significant reduction of the treatment field. Better localization of the prostate at the time of treatment is therefore needed, e.g. using a cone-beam computed tomography (CT) system integrated with the linear accelerator. Localization of the prostate relies upon manual delineation of contours in successive axial CT slices or interactive alignment and is fairly time-consuming. A faster method is required for on-line or off-line image-guided radiotherapy, because of prostate motion, for patient throughput and efficiency. Therefore, we developed an automatic method to localize the prostate, based on 3D gray value registration. Methods and materials: A study was performed on conventional repeat CT scans of 19 prostate cancer patients to develop the methodology to localize the prostate. For each patient, 8-13 repeat CT scans were made during the course of treatment. First, the planning CT scan and the repeat CT scan were registered onto the rigid bony structures. Then, the delineated prostate in the planning CT scan was enlarged by an optimum margin of 5 mm to define a region of interest in the planning CT scan that contained enough gray value information for registration. Subsequently, this region was automatically registered to a repeat CT scan using 3D gray value registration to localize the prostate. The performance of automatic prostate localization was compared to prostate localization using contours. Therefore, a reference set was generated by registering the delineated contours of the prostates in all scans of all patients. Gray value registrations that showed large differences with respect to contour registrations were detected with a χ 2

  6. Reverse alignment "mirror image" visualization as a laparoscopic training tool improves task performance.

    Science.gov (United States)

    Dunnican, Ward J; Singh, T Paul; Ata, Ashar; Bendana, Emma E; Conlee, Thomas D; Dolce, Charles J; Ramakrishnan, Rakesh

    2010-06-01

    Reverse alignment (mirror image) visualization is a disconcerting situation occasionally faced during laparoscopic operations. This occurs when the camera faces back at the surgeon in the opposite direction from which the surgeon's body and instruments are facing. Most surgeons will attempt to optimize trocar and camera placement to avoid this situation. The authors' objective was to determine whether the intentional use of reverse alignment visualization during laparoscopic training would improve performance. A standard box trainer was configured for reverse alignment, and 34 medical students and junior surgical residents were randomized to train with either forward alignment (DIRECT) or reverse alignment (MIRROR) visualization. Enrollees were tested on both modalities before and after a 4-week structured training program specific to their modality. Student's t test was used to determine differences in task performance between the 2 groups. Twenty-one participants completed the study (10 DIRECT, 11 MIRROR). There were no significant differences in performance time between DIRECT or MIRROR participants during forward or reverse alignment initial testing. At final testing, DIRECT participants had improved times only in forward alignment performance; they demonstrated no significant improvement in reverse alignment performance. MIRROR participants had significant time improvement in both forward and reverse alignment performance at final testing. Reverse alignment imaging for laparoscopic training improves task performance for both reverse alignment and forward alignment tasks. This may be translated into improved performance in the operating room when faced with reverse alignment situations. Minimal lab training can account for drastic adaptation to this environment.

  7. A Bayesian nonrigid registration method to enhance intraoperative target definition in image-guided prostate procedures through uncertainty characterization

    International Nuclear Information System (INIS)

    Pursley, Jennifer; Risholm, Petter; Fedorov, Andriy; Tuncali, Kemal; Fennessy, Fiona M.; Wells, William M. III; Tempany, Clare M.; Cormack, Robert A.

    2012-01-01

    Purpose: This study introduces a probabilistic nonrigid registration method for use in image-guided prostate brachytherapy. Intraoperative imaging for prostate procedures, usually transrectal ultrasound (TRUS), is typically inferior to diagnostic-quality imaging of the pelvis such as endorectal magnetic resonance imaging (MRI). MR images contain superior detail of the prostate boundaries and provide substructure features not otherwise visible. Previous efforts to register diagnostic prostate images with the intraoperative coordinate system have been deterministic and did not offer a measure of the registration uncertainty. The authors developed a Bayesian registration method to estimate the posterior distribution on deformations and provide a case-specific measure of the associated registration uncertainty. Methods: The authors adapted a biomechanical-based probabilistic nonrigid method to register diagnostic to intraoperative images by aligning a physician's segmentations of the prostate in the two images. The posterior distribution was characterized with a Markov Chain Monte Carlo method; the maximum a posteriori deformation and the associated uncertainty were estimated from the collection of deformation samples drawn from the posterior distribution. The authors validated the registration method using a dataset created from ten patients with MRI-guided prostate biopsies who had both diagnostic and intraprocedural 3 Tesla MRI scans. The accuracy and precision of the estimated posterior distribution on deformations were evaluated from two predictive distance distributions: between the deformed central zone-peripheral zone (CZ-PZ) interface and the physician-labeled interface, and based on physician-defined landmarks. Geometric margins on the registration of the prostate's peripheral zone were determined from the posterior predictive distance to the CZ-PZ interface separately for the base, mid-gland, and apical regions of the prostate. Results: The authors observed

  8. Characterization of a PET Camera Optimized for Prostate Imaging

    International Nuclear Information System (INIS)

    Huber, Jennifer S.; Choong, Woon-Seng; Moses, William W.; Qi, Jinyi; Hu, Jicun; Wang, G.C.; Wilson, David; Oh, Sang; Huesman, RonaldH.; Derenzo, Stephen E.

    2005-01-01

    We present the characterization of a positron emission tomograph for prostate imaging that centers a patient between a pair of external curved detector banks (ellipse: 45 cm minor, 70 cm major axis). The distance between detector banks adjusts to allow patient access and to position the detectors as closely as possible for maximum sensitivity with patients of various sizes. Each bank is composed of two axial rows of 20 HR+ block detectors for a total of 80 detectors in the camera. The individual detectors are angled in the transaxial plane to point towards the prostate to reduce resolution degradation in that region. The detectors are read out by modified HRRT data acquisition electronics. Compared to a standard whole-body PET camera, our dedicated-prostate camera has the same sensitivity and resolution, less background (less randoms and lower scatter fraction) and a lower cost. We have completed construction of the camera. Characterization data and reconstructed images of several phantoms are shown. Sensitivity of a point source in the center is 946 cps/mu Ci. Spatial resolution is 4 mm FWHM in the central region

  9. Patient repositioning in prostate conformal radiotherapy by image fusion

    International Nuclear Information System (INIS)

    Betrouni, Nacim

    2004-01-01

    This research thesis first proposes an overview of imaging modalities which are generally used in radiotherapy, and briefly presents operation principles for ultrasound scans, scanners and MRI. The issue of patient repositioning in radiotherapy is then introduced, and already proposed solutions are presented. In the next part, the author addresses space location and ultrasound-based location, with a brief overview of methods used to track the displacements of a mobile object, in this case an ultrasound probe, and calibration. Then, after a presentation of the adopted method, and a discussion of published works related to contour extraction and to filtering and noise reduction methods in ultrasound imagery, the author addresses the issue of prostate segmentation based on ultrasound images. The next part deals with image registration with an overview of available methods and tools. A method of registration of pre-operation images obtained by MRI or scanner, and of intra-operation ultrasound images is proposed for a real-time registration. This method is aimed at supporting patient repositioning during prostate conformal radiotherapy

  10. Improved techniques in radionuclides imaging of prostatic lymph nodes

    International Nuclear Information System (INIS)

    Gardiner, R.A.; Fitzpatrick, J.M.; Constable, A.R.; Cranage, R.W.; O'Donoghue, E.P.N.; Wickham, J.E.A.

    1979-01-01

    Further improvements were made in the techniques of human prostatic lymphoscintigraphy, allowing better anatomical localisation of the areas of uptake of activity. A single median injection into the capsule of sup(99m)Tc labelled antimony sulphide colloid was found to give as good imaging as 2 injections on either side of the midline. By placing markers on the umbilicus, pubic symphysis and both anterior superior iliac spines, a 'pelvic grid' could be superimposed on the antero-posterior view. Further help with accurate localisation may be attained by taking 3 views; anterio-posterior, postero-anterior and lateral. In 9 instances, prostatic injection was performed without any sedation or anaesthesia. The resulting scintigrams were indistinguishable in quality from those of anaesthetised patients. (author)

  11. In vivo optoacoustic temperature imaging for image-guided cryotherapy of prostate cancer

    Science.gov (United States)

    Petrova, E. V.; Brecht, H. P.; Motamedi, M.; Oraevsky, A. A.; Ermilov, S. A.

    2018-03-01

    The objective of this study is to demonstrate in vivo the feasibility of optoacoustic temperature imaging during cryotherapy of prostate cancer. We developed a preclinical prototype optoacoustic temperature imager that included pulsed optical excitation at a wavelength of 805 nm, a modified clinical transrectal ultrasound probe, a parallel data acquisition system, image processing and visualization software. Cryotherapy of a canine prostate was performed in vivo using a commercial clinical system, Cryocare® CS, with an integrated ultrasound imaging. The universal temperature-dependent optoacoustic response of blood was employed to convert reconstructed optoacoustic images to temperature maps. Optoacoustic imaging of temperature during prostate cryotherapy was performed in the longitudinal view over a region of 30 mm (long)  ×  10 mm (deep) that covered the rectum, the Denonvilliers fascia, and the posterior portion of the treated gland. The transrectal optoacoustic images showed high-contrast vascularized regions, which were used for quantitative estimation of local temperature profiles. The constructed temperature maps and their temporal dynamics were consistent with the arrangement of the cryoprobe and readouts of the thermal needle sensors. The temporal profiles of the readouts from the thermal needle sensors and the temporal profile estimated from the normalized optoacoustic intensity of the selected vascularized region showed significant resemblance, except for the initial overshoot, that may be explained as a result of the physiological thermoregulatory compensation. The temperature was mapped with errors not exceeding  ±2 °C (standard deviation) consistent with the clinical requirements for monitoring cryotherapy of the prostate. In vivo results showed that the optoacoustic temperature imaging is a promising non-invasive technique for real-time imaging of tissue temperature during cryotherapy of prostate cancer, which can be combined

  12. In vivo Photoacoustic Imaging of Prostate Cancer Using Targeted Contrast Agent

    Science.gov (United States)

    2016-11-01

    AD______________ AWARD NUMBER: W81XWH-14-1-0242 TITLE: In Vivo Photoacoustic Imaging of Prostate Cancer Using Targeted Contrast Agent PRINCIPAL...TITLE AND SUBTITLE In vivo Photoacoustic Imaging of Prostate Cancer Using T argeted Contrast Agent 5a. CONTRACT NUMBER W81XWH-14-1-0242 5b. GRANT...diagnose prostate cancer based on the near-infrared optical absorption of either endogenous tissue constituents or exogenous contrast agents . Although

  13. Testicular Doses in Image-Guided Radiotherapy of Prostate Cancer

    International Nuclear Information System (INIS)

    Deng Jun; Chen Zhe; Yu, James B.; Roberts, Kenneth B.; Peschel, Richard E.; Nath, Ravinder

    2012-01-01

    Purpose: To investigate testicular doses contributed by kilovoltage cone-beam computed tomography (kVCBCT) during image-guided radiotherapy (IGRT) of prostate cancer. Methods and Materials: An EGS4 Monte Carlo code was used to calculate three-dimensional dose distributions from kVCBCT on 3 prostate cancer patients. Absorbed doses to various organs were compared between intensity-modulated radiotherapy (IMRT) treatments and kVCBCT scans. The impact of CBCT scanning mode, kilovoltage peak energy (kVp), and CBCT field span on dose deposition to testes and other organs was investigated. Results: In comparison with one 10-MV IMRT treatment, a 125-kV half-fan CBCT scan delivered 3.4, 3.8, 4.1, and 5.7 cGy to the prostate, rectum, bladder, and femoral heads, respectively, accounting for 1.7%, 3.2%, 3.2%, and 8.4% of megavoltage photon dose contributions. However, the testes received 2.9 cGy from the same CBCT scan, a threefold increase as compared with 0.7 cGy received during IMRT. With the same kVp, full-fan mode deposited much less dose to organs than half-fan mode, ranging from 9% less for prostate to 69% less for testes, except for rectum, where full-fan mode delivered 34% more dose. As photon beam energy increased from 60 to 125 kV, kVCBCT-contributed doses increased exponentially for all organs, irrespective of scanning mode. Reducing CBCT field span from 30 to 10 cm in the superior–inferior direction cut testicular doses from 5.7 to 0.2 cGy in half-fan mode and from 1.5 to 0.1 cGy in full-fan mode. Conclusions: Compared with IMRT, kVCBCT-contributed doses to the prostate, rectum, bladder, and femoral heads are clinically insignificant, whereas dose to the testes is threefold more. Full-fan CBCT usually deposits much less dose to organs (except for rectum) than half-fan mode in prostate patients. Kilovoltage CBCT–contributed doses increase exponentially with photon beam energy. Reducing CBCT field significantly cuts doses to testes and other organs.

  14. Testicular Doses in Image-Guided Radiotherapy of Prostate Cancer

    Energy Technology Data Exchange (ETDEWEB)

    Deng Jun, E-mail: jun.deng@yale.edu [Department of Therapeutic Radiology, Yale University, New Haven, CT (United States); Chen Zhe; Yu, James B.; Roberts, Kenneth B.; Peschel, Richard E.; Nath, Ravinder [Department of Therapeutic Radiology, Yale University, New Haven, CT (United States)

    2012-01-01

    Purpose: To investigate testicular doses contributed by kilovoltage cone-beam computed tomography (kVCBCT) during image-guided radiotherapy (IGRT) of prostate cancer. Methods and Materials: An EGS4 Monte Carlo code was used to calculate three-dimensional dose distributions from kVCBCT on 3 prostate cancer patients. Absorbed doses to various organs were compared between intensity-modulated radiotherapy (IMRT) treatments and kVCBCT scans. The impact of CBCT scanning mode, kilovoltage peak energy (kVp), and CBCT field span on dose deposition to testes and other organs was investigated. Results: In comparison with one 10-MV IMRT treatment, a 125-kV half-fan CBCT scan delivered 3.4, 3.8, 4.1, and 5.7 cGy to the prostate, rectum, bladder, and femoral heads, respectively, accounting for 1.7%, 3.2%, 3.2%, and 8.4% of megavoltage photon dose contributions. However, the testes received 2.9 cGy from the same CBCT scan, a threefold increase as compared with 0.7 cGy received during IMRT. With the same kVp, full-fan mode deposited much less dose to organs than half-fan mode, ranging from 9% less for prostate to 69% less for testes, except for rectum, where full-fan mode delivered 34% more dose. As photon beam energy increased from 60 to 125 kV, kVCBCT-contributed doses increased exponentially for all organs, irrespective of scanning mode. Reducing CBCT field span from 30 to 10 cm in the superior-inferior direction cut testicular doses from 5.7 to 0.2 cGy in half-fan mode and from 1.5 to 0.1 cGy in full-fan mode. Conclusions: Compared with IMRT, kVCBCT-contributed doses to the prostate, rectum, bladder, and femoral heads are clinically insignificant, whereas dose to the testes is threefold more. Full-fan CBCT usually deposits much less dose to organs (except for rectum) than half-fan mode in prostate patients. Kilovoltage CBCT-contributed doses increase exponentially with photon beam energy. Reducing CBCT field significantly cuts doses to testes and other organs.

  15. Imaging Prostate Cancer Microenvironment by Collagen Hybridization

    Science.gov (United States)

    2015-10-01

    diagnosis, staging, and treatment of numerous connective tissue disorders and diseases. Standard antibody staining methods that rely on epitopes of a...CMP can be used to detect mechanical damage to collagen in tendon which could be used for diagnostic and therapeutics of musculoskeletal injury which...13. SUPPLEMENTARY NOTES 14. ABSTRACT The major goal of the proposed work is to develop new PCa imaging methods based on the collagen mimetic peptide

  16. Imaging Prostate Cancer with Positron Emission Tomography

    Science.gov (United States)

    2014-07-01

    multimodal imaging platforms. We have developed peptides that are specific for the FAP active site, conjugated them to the cross- bridged macrocycle 4,11...based pendant arms. Reaction with excess chelator for an extended period finally afforded 5 mg of each product in 95% purity. Additionally 5 mg...proton sponge behavior of the cross- bridged macrocycle14,15. Radiolabeled conjugates can be prepared with a specific activity of 37 MBq (1 mCi)/µg

  17. Overview of current multiparametric magnetic resonance imaging approach in the diagnosis and staging of prostate cancer

    Directory of Open Access Journals (Sweden)

    Hasan Aydın

    2015-04-01

    Full Text Available This article is primarily based on the utility and validity of multiparametric magnetic resonance imaging in the diagnosis and staging of prostate gland tumors. Multiparametric magnetic resonance imaging is an emerging, useful approach for evaluating and detecting prostate cancers. It also aids in the management of a tumor and improve the care and follow-up of patients.

  18. Prostate Ultrasound

    Medline Plus

    Full Text Available ... Z Ultrasound - Prostate Ultrasound of the prostate uses sound waves to produce pictures of a man’s prostate ... pictures of the inside of the body using sound waves. Ultrasound imaging, also called ultrasound scanning or ...

  19. Enhanced spatio-temporal alignment of plantar pressure image sequences using B-splines.

    Science.gov (United States)

    Oliveira, Francisco P M; Tavares, João Manuel R S

    2013-03-01

    This article presents an enhanced methodology to align plantar pressure image sequences simultaneously in time and space. The temporal alignment of the sequences is accomplished using B-splines in the time modeling, and the spatial alignment can be attained using several geometric transformation models. The methodology was tested on a dataset of 156 real plantar pressure image sequences (3 sequences for each foot of the 26 subjects) that was acquired using a common commercial plate during barefoot walking. In the alignment of image sequences that were synthetically deformed both in time and space, an outstanding accuracy was achieved with the cubic B-splines. This accuracy was significantly better (p align real image sequences with unknown transformation involved, the alignment based on cubic B-splines also achieved superior results than our previous methodology (p alignment on the dynamic center of pressure (COP) displacement was also assessed by computing the intraclass correlation coefficients (ICC) before and after the temporal alignment of the three image sequence trials of each foot of the associated subject at six time instants. The results showed that, generally, the ICCs related to the medio-lateral COP displacement were greater when the sequences were temporally aligned than the ICCs of the original sequences. Based on the experimental findings, one can conclude that the cubic B-splines are a remarkable solution for the temporal alignment of plantar pressure image sequences. These findings also show that the temporal alignment can increase the consistency of the COP displacement on related acquired plantar pressure image sequences.

  20. Comparison of daily megavoltage electronic portal imaging or kilovoltage imaging with marker seeds to ultrasound imaging or skin marks for prostate localization and treatment positioning in patients with prostate cancer

    International Nuclear Information System (INIS)

    Serago, Christopher F.; Buskirk, Steven J.; Igel, Todd C.; Gale, Ashley A.; Serago, Nicole E.; Earle, John D.

    2006-01-01

    Purpose: To compare the accuracy of imaging modalities, immobilization, localization, and positioning techniques in patients with prostate cancer. Methods and Materials: Thirty-five patients with prostate cancer had gold marker seeds implanted transrectally and were treated with fractionated radiotherapy. Twenty of the 35 patients had limited immobilization; the remaining had a vacuum-based immobilization. Patient positioning consisted of alignment with lasers to skin marks, ultrasound or kilovoltage X-ray imaging, optical guidance using infrared reflectors, and megavoltage electronic portal imaging (EPI). The variance of each positioning technique was compared to the patient position determined from the pretreatment EPI. Results: With limited immobilization, the average difference between the skin marks' laser position and EPI pretreatment position is 9.1 ± 5.3 mm, the average difference between the skin marks' infrared position and EPI pretreatment position is 11.8 ± 7.2 mm, the average difference between the ultrasound position and EPI pretreatment position is 7.0 ± 4.6 mm, the average difference between kV imaging and EPI pretreatment position is 3.5 ± 3.1 mm, and the average intrafraction movement during treatment is 3.4 ± 2.7 mm. For the patients with the vacuum-style immobilization, the average difference between the skin marks' laser position and EPI pretreatment position is 10.7 ± 4.6 mm, the average difference between kV imaging and EPI pretreatment position is 1.9 ± 1.5 mm, and the average intrafraction movement during treatment is 2.1 ± 1.5 mm. Conclusions: Compared with use of skin marks, ultrasound imaging for positioning provides an increased degree of agreement to EPI-based positioning, though not as favorable as kV imaging fiducial seeds. Intrafraction movement during treatment decreases with improved immobilization

  1. Robust image alignment for cryogenic transmission electron microscopy.

    Science.gov (United States)

    McLeod, Robert A; Kowal, Julia; Ringler, Philippe; Stahlberg, Henning

    2017-03-01

    Cryo-electron microscopy recently experienced great improvements in structure resolution due to direct electron detectors with improved contrast and fast read-out leading to single electron counting. High frames rates enabled dose fractionation, where a long exposure is broken into a movie, permitting specimen drift to be registered and corrected. The typical approach for image registration, with high shot noise and low contrast, is multi-reference (MR) cross-correlation. Here we present the software package Zorro, which provides robust drift correction for dose fractionation by use of an intensity-normalized cross-correlation and logistic noise model to weight each cross-correlation in the MR model and filter each cross-correlation optimally. Frames are reliably registered by Zorro with low dose and defocus. Methods to evaluate performance are presented, by use of independently-evaluated even- and odd-frame stacks by trajectory comparison and Fourier ring correlation. Alignment of tiled sub-frames is also introduced, and demonstrated on an example dataset. Zorro source code is available at github.com/CINA/zorro. Copyright © 2016 Elsevier Inc. All rights reserved.

  2. Efficient and robust model-to-image alignment using 3D scale-invariant features.

    Science.gov (United States)

    Toews, Matthew; Wells, William M

    2013-04-01

    This paper presents feature-based alignment (FBA), a general method for efficient and robust model-to-image alignment. Volumetric images, e.g. CT scans of the human body, are modeled probabilistically as a collage of 3D scale-invariant image features within a normalized reference space. Features are incorporated as a latent random variable and marginalized out in computing a maximum a posteriori alignment solution. The model is learned from features extracted in pre-aligned training images, then fit to features extracted from a new image to identify a globally optimal locally linear alignment solution. Novel techniques are presented for determining local feature orientation and efficiently encoding feature intensity in 3D. Experiments involving difficult magnetic resonance (MR) images of the human brain demonstrate FBA achieves alignment accuracy similar to widely-used registration methods, while requiring a fraction of the memory and computation resources and offering a more robust, globally optimal solution. Experiments on CT human body scans demonstrate FBA as an effective system for automatic human body alignment where other alignment methods break down. Copyright © 2012 Elsevier B.V. All rights reserved.

  3. Molecular imaging of prostate cancer: translating molecular biology approaches into the clinical realm.

    Science.gov (United States)

    Vargas, Hebert Alberto; Grimm, Jan; F Donati, Olivio; Sala, Evis; Hricak, Hedvig

    2015-05-01

    The epidemiology of prostate cancer has dramatically changed since the introduction of prostate-specific antigen (PSA) screening in the 1980's. Most prostate cancers today are detected at early stages of the disease and are considered 'indolent'; however, some patients' prostate cancers demonstrate a more aggressive behaviour which leads to rapid progression and death. Increasing understanding of the biology underlying the heterogeneity that characterises this disease has led to a continuously evolving role of imaging in the management of prostate cancer. Functional and metabolic imaging techniques are gaining importance as the impact on the therapeutic paradigm has shifted from structural tumour detection alone to distinguishing patients with indolent tumours that can be managed conservatively (e.g., by active surveillance) from patients with more aggressive tumours that may require definitive treatment with surgery or radiation. In this review, we discuss advanced imaging techniques that allow direct visualisation of molecular interactions relevant to prostate cancer and their potential for translation to the clinical setting in the near future. The potential use of imaging to follow molecular events during drug therapy as well as the use of imaging agents for therapeutic purposes will also be discussed. • Advanced imaging techniques allow direct visualisation of molecular interactions in prostate cancer. • MRI/PET, optical and Cerenkov imaging facilitate the translation of molecular biology. • Multiple compounds targeting PSMA expression are currently undergoing clinical translation. • Other targets (e.g., PSA, prostate-stem cell antigen, GRPR) are in development.

  4. Clinical stage T1c prostate cancer: evaluation with endorectal MR imaging and MR spectroscopic imaging.

    Science.gov (United States)

    Zhang, Jingbo; Hricak, Hedvig; Shukla-Dave, Amita; Akin, Oguz; Ishill, Nicole M; Carlino, Lauren J; Reuter, Victor E; Eastham, James A

    2009-11-01

    To assess the diagnostic accuracy of endorectal magnetic resonance (MR) imaging and MR spectroscopic imaging for prediction of the pathologic stage of prostate cancer and the presence of clinically nonimportant disease in patients with clinical stage T1c prostate cancer. The institutional review board approved-and waived the informed patient consent requirement for-this HIPAA-compliant study involving 158 patients (median age, 58 years; age range, 40-76 years) who had clinical stage T1c prostate cancer, had not been treated preoperatively, and underwent combined 1.5-T endorectal MR imaging-MR spectroscopic imaging between January 2003 and March 2004 before undergoing radical prostatectomy. On the MR images and combined endorectal MR-MR spectroscopic images, two radiologists retrospectively and independently rated the likelihood of cancer in 12 prostate regions and the likelihoods of extracapsular extension (ECE), seminal vesicle invasion (SVI), and adjacent organ invasion by using a five-point scale, and they determined the probability of clinically nonimportant prostate cancer by using a four-point scale. Whole-mount step-section pathology maps were used for imaging-pathologic analysis correlation. Receiver operating characteristic curves were constructed and areas under the curves (AUCs) were estimated nonparametrically for assessment of reader accuracy. At surgical-pathologic analysis, one (0.6%) patient had no cancer; 124 (78%) patients, organ-confined (stage pT2) disease; 29 (18%) patients, ECE (stage pT3a); two (1%) patients, SVI (stage pT3b); and two (1%) patients, bladder neck invasion (stage pT4). Forty-six (29%) patients had a total tumor volume of less than 0.5 cm(3). With combined MR imaging-MR spectroscopic imaging, the two readers achieved 80% accuracy in disease staging and AUCs of 0.62 and 0.71 for the prediction of clinically nonimportant cancer. Clinical stage T1c prostate cancers are heterogeneous in pathologic stage and volume. MR imaging may

  5. Short-lag spatial coherence beamforming of photoacoustic images for enhanced visualization of prostate brachytherapy seeds

    OpenAIRE

    Lediju Bell, Muyinatu A.; Kuo, Nathanael; Song, Danny Y.; Boctor, Emad M.

    2013-01-01

    Prostate brachytherapy, administered by implanting tiny radioactive seeds to treat prostate cancer, currently relies on transrectal ultrasound imaging for intraoperative visualization of the metallic seeds. Photoacoustic (PA) imaging has been suggested as a feasible alternative to ultrasound imaging due to its superior sensitivity to metal surrounded by tissue. However, PA images suffer from poor contrast when seeds are distant from the light source. We propose a transperineal light delivery ...

  6. Quantitative Time-Resolved Fluorescence Imaging of Androgen Receptor and Prostate-Specific Antigen in Prostate Tissue Sections.

    Science.gov (United States)

    Krzyzanowska, Agnieszka; Lippolis, Giuseppe; Helczynski, Leszek; Anand, Aseem; Peltola, Mari; Pettersson, Kim; Lilja, Hans; Bjartell, Anders

    2016-05-01

    Androgen receptor (AR) and prostate-specific antigen (PSA) are expressed in the prostate and are involved in prostate cancer (PCa). The aim of this study was to develop reliable protocols for reproducible quantification of AR and PSA in benign and malignant prostate tissue using time-resolved fluorescence (TRF) imaging techniques. AR and PSA were detected with TRF in tissue microarrays from 91 PCa patients. p63/ alpha-methylacyl-CoA racemase (AMACR) staining on consecutive sections was used to categorize tissue areas as benign or cancerous. Automated image analysis was used to quantify staining intensity. AR intensity was significantly higher in AMACR+ and lower in AMACR- cancer areas as compared with benign epithelium. The PSA intensity was significantly lower in cancer areas, particularly in AMACR- glands. The AR/PSA ratio varied significantly in the AMACR+ tumor cells as compared with benign glands. There was a trend of more rapid disease progression in patients with higher AR/PSA ratios in the AMACR- areas. This study demonstrates the feasibility of developing reproducible protocols for TRF imaging and automated image analysis to study the expression of AR and PSA in benign and malignant prostate. It also highlighted the differences in AR and PSA protein expression within AMACR- and AMACR+ cancer regions. © 2016 The Histochemical Society.

  7. The Impact of Imaging Modality on the Measurement of Coronal Plane Alignment After Total Knee Arthroplasty.

    Science.gov (United States)

    Nam, Denis; Vajapey, Sravya; Nunley, Ryan M; Barrack, Robert L

    2016-10-01

    The optimal coronal alignment after total knee arthroplasty (TKA) has become an area of increased debate. Sources of variability among investigations include the radiographic technique used for both preoperative surgical planning and postoperative alignment assessments. This study's purpose was to assess the impact of the imaging modality used on the measurement of coronal plane alignment after TKA. A consecutive series of patients undergoing TKA using the same cruciate-retaining prosthesis were included for analysis. Postoperatively, all patients received both a rotationally controlled, scout computed tomography scan and a hip-knee-ankle (HKA) image using the EOS Imaging system (EOS Inc., Paris, France). Two, independent observers measured the HKA angle, and femoral and tibial component alignment from each image. After classifying overall and component alignment as neutral, varus, or valgus, 40.6% (65 of 160) of knees had a discordant alignment classification for HKA, 28.1% (45 of 160) for femoral component alignment, and 26.9% (43 of 160) for tibial component alignment between their computed tomography and EOS images. Overall, 24.4% (39 of 160) of patients had a HKA difference of ≥3° between the 2 images, whereas 18.8% (30 of 160) and 20.0% (32 of 160) of patients had a femoral and tibial component alignment difference of ≥2°, respectively. Significant differences are present when comparing 2 measurement techniques of mechanical alignment after TKA. The impact of imaging modality on postoperative assessments must be accounted for and be consistent when comparing the results of different investigations. Copyright © 2016 Elsevier Inc. All rights reserved.

  8. Program for PET image alignment: Effects on calculated differences in cerebral metabolic rates for glucose

    International Nuclear Information System (INIS)

    Phillips, R.L.; London, E.D.; Links, J.M.; Cascella, N.G.

    1990-01-01

    A program was developed to align positron emission tomography images from multiple studies on the same subject. The program allowed alignment of two images with a fineness of one-tenth the width of a pixel. The indications and effects of misalignment were assessed in eight subjects from a placebo-controlled double-blind crossover study on the effects of cocaine on regional cerebral metabolic rates for glucose. Visual examination of a difference image provided a sensitive and accurate tool for assessing image alignment. Image alignment within 2.8 mm was essential to reduce variability of measured cerebral metabolic rates for glucose. Misalignment by this amount introduced errors on the order of 20% in the computed metabolic rate for glucose. These errors propagate to the difference between metabolic rates for a subject measured in basal versus perturbed states

  9. Prostate-specific membrane antigen-based imaging in prostate cancer: impact on clinical decision making process.

    Science.gov (United States)

    Demirkol, Mehmet Onur; Acar, Ömer; Uçar, Burcu; Ramazanoğlu, Sultan Rana; Sağlıcan, Yeşim; Esen, Tarık

    2015-05-01

    There is an ongoing need for an accurate imaging modality which can be used for staging purposes, metastatic evaluation, predicting biologic aggresiveness and investigating recurrent disease in prostate cancer. Prostate specific membrane antigen, given its favorable molecular characteristics, holds a promise as an ideal target for prostate cancer-specific nuclear imaging. In this study, we evaluated our initial results of PSMA based PET/CT imaging in prostate cancer. A total of 22 patients with a median age and serum PSA level of 68 years and 4.15 ng/ml, respectively underwent Ga-68 PSMA PET/CT in our hospital between Februrary and August 2014. Their charts were retrospectively reviewed in order to document the clinical characteristics, the indications for and the results of PSMA based imaging and the impact of Ga-68 PSMA PET/CT findings on disease management. The most common indications were rising PSA after local ± adjuvant treatment followed by staging and metastatic evaluation before definitive or salvage treatment. All except 2 patients had prostatic ± extraprostatic PSMA positive lesions. For those who had a positive result; treatment strategies were tailored accordingly. Above the PSA level of 2 ng/ml, none of the PSMA based nuclear imaging studies revealed negative results. PSMA based nuclear imaging has significantly impacted our way of handling patients with prostate cancer. Its preliminary performance in different clinical scenarios and ability to detect lesions even in low PSA values seems fairly promising and deserves to be supplemented with further clinical studies. © 2015 Wiley Periodicals, Inc.

  10. Method comparison of ultrasound and kilovoltage x-ray fiducial marker imaging for prostate radiotherapy targeting

    Science.gov (United States)

    Fuller, Clifton David; Thomas, Charles R., Jr.; Schwartz, Scott; Golden, Nanalei; Ting, Joe; Wong, Adrian; Erdogmus, Deniz; Scarbrough, Todd J.

    2006-10-01

    Several measurement techniques have been developed to address the capability for target volume reduction via target localization in image-guided radiotherapy; among these have been ultrasound (US) and fiducial marker (FM) software-assisted localization. In order to assess interchangeability between methods, US and FM localization were compared using established techniques for determination of agreement between measurement methods when a 'gold-standard' comparator does not exist, after performing both techniques daily on a sequential series of patients. At least 3 days prior to CT simulation, four gold seeds were placed within the prostate. FM software-assisted localization utilized the ExacTrac X-Ray 6D (BrainLab AG, Germany) kVp x-ray image acquisition system to determine prostate position; US prostate targeting was performed on each patient using the SonArray (Varian, Palo Alto, CA). Patients were aligned daily using laser alignment of skin marks. Directional shifts were then calculated by each respective system in the X, Y and Z dimensions before each daily treatment fraction, previous to any treatment or couch adjustment, as well as a composite vector of displacement. Directional shift agreement in each axis was compared using Altman-Bland limits of agreement, Lin's concordance coefficient with Partik's grading schema, and Deming orthogonal bias-weighted correlation methodology. 1019 software-assisted shifts were suggested by US and FM in 39 patients. The 95% limits of agreement in X, Y and Z axes were ±9.4 mm, ±11.3 mm and ±13.4, respectively. Three-dimensionally, measurements agreed within 13.4 mm in 95% of all paired measures. In all axes, concordance was graded as 'poor' or 'unacceptable'. Deming regression detected proportional bias in both directional axes and three-dimensional vectors. Our data suggest substantial differences between US and FM image-guided measures and subsequent suggested directional shifts. Analysis reveals that the vast majority of

  11. T2*-weighted image/T2-weighted image fusion in postimplant dosimetry of prostate brachytherapy

    International Nuclear Information System (INIS)

    Katayama, Norihisa; Takemoto, Mitsuhiro; Yoshio, Kotaro

    2011-01-01

    Computed tomography (CT)/magnetic resonance imaging (MRI) fusion is considered to be the best method for postimplant dosimetry of permanent prostate brachytherapy; however, it is inconvenient and costly. In T2 * -weighted image (T2 * -WI), seeds can be easily detected without the use of an intravenous contrast material. We present a novel method for postimplant dosimetry using T2 * -WI/T2-weighted image (T2-WI) fusion. We compared the outcomes of T2 * -WI/T2-WI fusion-based and CT/T2-WI fusion-based postimplant dosimetry. Between April 2008 and July 2009, 50 consecutive prostate cancer patients underwent brachytherapy. All the patients were treated with 144 Gy of brachytherapy alone. Dose-volume histogram (DVH) parameters (prostate D90, prostate V100, prostate V150, urethral D10, and rectal D2cc) were prospectively compared between T2 * -WI/T2-WI fusion-based and CT/T2-WI fusion-based dosimetry. All the DVH parameters estimated by T2 * -WI/T2-WI fusion-based dosimetry strongly correlated to those estimated by CT/T2-WI fusion-based dosimetry (0.77≤ R ≤0.91). No significant difference was observed in these parameters between the two methods, except for prostate V150 (p=0.04). These results show that T2 * -WI/T2-WI fusion-based dosimetry is comparable or superior to MRI-based dosimetry as previously reported, because no intravenous contrast material is required. For some patients, rather large differences were observed in the value between the 2 methods. We thought these large differences were a result of seed miscounts in T2 * -WI and shifts in fusion. Improving the image quality of T2 * -WI and the image acquisition speed of T2 * -WI and T2-WI may decrease seed miscounts and fusion shifts. Therefore, in the future, T2 * -WI/T2-WI fusion may be more useful for postimplant dosimetry of prostate brachytherapy. (author)

  12. Normal appearance of the prostate and seminal tract: MR imaging using an endorectal surface coil

    International Nuclear Information System (INIS)

    Kim, Myeong Jin; Lee, Jong Tae; Lee, Moo Sang; Choi, Pil Sik; Hong, Sung Joon; Lee, Yeon Hee; Choi, Hak Yong

    1994-01-01

    To assess the ability of MR imaging with an endorectal surface coil for the depiction of normal anatomical structure of prostate and its adjacent organs. MR imaging using an endorectal surface coil was performed in 23 male patients(age ; 20-75) to evaluate various prostatic and vasovesicular disorders, i. e, 14 cases of ejaculatory problems, 3 cases of hypogonadism, and 4 cases of prostatic cancers and 2 cases of benign prostatic hyperplasia. MR images were obtained with axial, sagittal and coronal fast spin echo long TR/TE images and axial spin echo short TR/TE images. Field of views was 10-12 cm and scan thickness was 3-5 mm. Depiction of normal anatomcial structures was excellent in all cases. On T2WI, zonal anatomy of the prostate and prostatic urethra, urethral crest, and ejaculatory duct were cleary visualized. On T1WI, periprostatic fat plane is more cleary visualized. On transverse images, periprostatic structures were well visualized on T1WI,and on T2WI, anterior fibromuscular stroma, transition zone and peripheral zone could be readily differentiated. Coronal images were more helpful in visualization of both central and peripheral zones. Vas deferens, ejaculatory duct and vermontanum were also more easily defined on these images. Sagittal images was helpful in the depiction of anterior fibromuscular stroma, central zone and peripheral zone with prostatic urethra and ejaculatory duct in a single plane. High resolution MR imaging with an endorectal surface coil can readily visualize the normal anatomy of the prostate and its related structures and may be useful in the evaluation of various diseases of prostate and vasvesicular system

  13. Normal appearance of the prostate and seminal tract: MR imaging using an endorectal surface coil

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Myeong Jin; Lee, Jong Tae; Lee, Moo Sang; Choi, Pil Sik; Hong, Sung Joon; Lee, Yeon Hee; Choi, Hak Yong [Yonsei University College of Medicine, Seoul (Korea, Republic of)

    1994-06-15

    To assess the ability of MR imaging with an endorectal surface coil for the depiction of normal anatomical structure of prostate and its adjacent organs. MR imaging using an endorectal surface coil was performed in 23 male patients(age ; 20-75) to evaluate various prostatic and vasovesicular disorders, i. e, 14 cases of ejaculatory problems, 3 cases of hypogonadism, and 4 cases of prostatic cancers and 2 cases of benign prostatic hyperplasia. MR images were obtained with axial, sagittal and coronal fast spin echo long TR/TE images and axial spin echo short TR/TE images. Field of views was 10-12 cm and scan thickness was 3-5 mm. Depiction of normal anatomcial structures was excellent in all cases. On T2WI, zonal anatomy of the prostate and prostatic urethra, urethral crest, and ejaculatory duct were cleary visualized. On T1WI, periprostatic fat plane is more cleary visualized. On transverse images, periprostatic structures were well visualized on T1WI,and on T2WI, anterior fibromuscular stroma, transition zone and peripheral zone could be readily differentiated. Coronal images were more helpful in visualization of both central and peripheral zones. Vas deferens, ejaculatory duct and vermontanum were also more easily defined on these images. Sagittal images was helpful in the depiction of anterior fibromuscular stroma, central zone and peripheral zone with prostatic urethra and ejaculatory duct in a single plane. High resolution MR imaging with an endorectal surface coil can readily visualize the normal anatomy of the prostate and its related structures and may be useful in the evaluation of various diseases of prostate and vasvesicular system.

  14. Evaluation of permanent I-125 prostate implants using radiography and magnetic resonance imaging

    International Nuclear Information System (INIS)

    Moerland, Marinus A.; Wijrdeman, Harm K.; Beersma, Robert; Bakker, Chris J.G.; Battermann, Jan J.

    1997-01-01

    Purpose: The aim of this study is the evaluation of permanent I-125 prostate implants using radiography and magnetic resonance imaging (MRI). Methods and Materials: Twenty-one patients underwent radiography on the simulator and MRI within 3 days after implantation of the I-125 seeds. Isocentric radiographs were used for reconstruction of the seed distribution, after which registration with the seed-induced signal voids on MRI provided the seed positions in relation to the prostate. The prostate was contoured on the transversal magnetic resonance images, and dose-volume histograms were computed to evaluate the implants. The validity of the ellipsoidal prostate volume approximation, as applied in preimplant dose calculation, was assessed by comparison of ellipsoidal volumes given by prostate width, height, and length and prostate volumes obtained by a slice-by-slice contouring method, both on postimplant MRI. Prostate volume changes due to postimplant prostate swelling were assessed from radiographs taken at 3 days and 1 month after the implantation. Results: The seeds were readily identified on T 1 -weighted spin-echo images and matched with the seed distribution reconstructed from the isocentric radiographs. The matching error, averaged over 21 patients, amounted to 1.8 ± 0.4 mm (mean ± standard deviation). The fractions of the prostate volumes receiving the prescribed matched peripheral dose (MPD) ranged from 32 to 71% (mean ± standard deviation: 60 ± 10%). Prostate volumes, obtained by the contouring method on postimplant MRI, were a factor 1.5 ± 0.3 larger than the ellipsoidal volumes given by the prostate dimensions on postimplant MRI. Prostate volumes 3 days after the implantation were a factor 1.3 ± 0.2 larger than the prostate volumes 1 month after the implantation. Registration of the reconstructed seed distribution and the MR images showed inaccuracies in seed placement, for example, two or more seeds clustering together or seeds outside the prostate

  15. Intra-fractional uncertainties in image-guided intensity-modulated radiotherapy (IMRT) of prostate cancer

    International Nuclear Information System (INIS)

    Polat, Buelent; Guenther, Iris; Wilbert, Juergen; Goebel, Joachim; Sweeney, Reinhart A.; Flentje, Michael; Guckenberger, Matthias

    2008-01-01

    To evaluate intra-fractional uncertainties during intensity-modulated radiotherapy (IMRT) of prostate cancer. During IMRT of 21 consecutive patients, kilovolt (kV) cone-beam computed tomography (CBCT) images were acquired prior to and immediately after treatment: a total of 252 treatment fractions with 504 CBCT studies were basis of this analysis. The prostate position in anterior-posterior (AP) direction was determined using contour matching; patient set-up based on the pelvic bony anatomy was evaluated using automatic image registration. Internal variability of the prostate position was the difference between absolute prostate and patient position errors. Intra-fractional changes of prostate position, patient position, rectal distension in AP direction and bladder volume were analyzed. With a median treatment time of 16 min, intra-fractional drifts of the prostate were > 5 mm in 12% of all fractions and a margin of 6 mm was calculated for compensation of this uncertainty. Mobility of the prostate was independent from the bony anatomy with poor correlation between absolute prostate motion and motion of the bony anatomy (R 2 = 0.24). A systematic increase of bladder filling by 41 ccm on average was observed; however, these changes did not influence the prostate position. Small variations of the prostate position occurred independently from intra-fractional changes of the rectal distension; a weak correlation between large internal prostate motion and changes of the rectal volume was observed (R 2 = 0.55). Clinically significant intra-fractional changes of the prostate position were observed and margins of 6 mm were calculated for this intra-fractional uncertainty. Repeated or continuous verification of the prostate position may allow further margin reduction. (orig.)

  16. Intra-fractional uncertainties in image-guided intensity-modulated radiotherapy (IMRT) of prostate cancer

    Energy Technology Data Exchange (ETDEWEB)

    Polat, Buelent; Guenther, Iris; Wilbert, Juergen; Goebel, Joachim; Sweeney, Reinhart A.; Flentje, Michael; Guckenberger, Matthias [Wuerzburg Univ. (Germany). Dept. of Radiation Oncology

    2008-12-15

    To evaluate intra-fractional uncertainties during intensity-modulated radiotherapy (IMRT) of prostate cancer. During IMRT of 21 consecutive patients, kilovolt (kV) cone-beam computed tomography (CBCT) images were acquired prior to and immediately after treatment: a total of 252 treatment fractions with 504 CBCT studies were basis of this analysis. The prostate position in anterior-posterior (AP) direction was determined using contour matching; patient set-up based on the pelvic bony anatomy was evaluated using automatic image registration. Internal variability of the prostate position was the difference between absolute prostate and patient position errors. Intra-fractional changes of prostate position, patient position, rectal distension in AP direction and bladder volume were analyzed. With a median treatment time of 16 min, intra-fractional drifts of the prostate were > 5 mm in 12% of all fractions and a margin of 6 mm was calculated for compensation of this uncertainty. Mobility of the prostate was independent from the bony anatomy with poor correlation between absolute prostate motion and motion of the bony anatomy (R{sup 2} = 0.24). A systematic increase of bladder filling by 41 ccm on average was observed; however, these changes did not influence the prostate position. Small variations of the prostate position occurred independently from intra-fractional changes of the rectal distension; a weak correlation between large internal prostate motion and changes of the rectal volume was observed (R{sup 2} = 0.55). Clinically significant intra-fractional changes of the prostate position were observed and margins of 6 mm were calculated for this intra-fractional uncertainty. Repeated or continuous verification of the prostate position may allow further margin reduction. (orig.)

  17. Robust through-the-wall radar image classification using a target-model alignment procedure.

    Science.gov (United States)

    Smith, Graeme E; Mobasseri, Bijan G

    2012-02-01

    A through-the-wall radar image (TWRI) bears little resemblance to the equivalent optical image, making it difficult to interpret. To maximize the intelligence that may be obtained, it is desirable to automate the classification of targets in the image to support human operators. This paper presents a technique for classifying stationary targets based on the high-range resolution profile (HRRP) extracted from 3-D TWRIs. The dependence of the image on the target location is discussed using a system point spread function (PSF) approach. It is shown that the position dependence will cause a classifier to fail, unless the image to be classified is aligned to a classifier-training location. A target image alignment technique based on deconvolution of the image with the system PSF is proposed. Comparison of the aligned target images with measured images shows the alignment process introducing normalized mean squared error (NMSE) ≤ 9%. The HRRP extracted from aligned target images are classified using a naive Bayesian classifier supported by principal component analysis. The classifier is tested using a real TWRI of canonical targets behind a concrete wall and shown to obtain correct classification rates ≥ 97%. © 2011 IEEE

  18. Impact of different setup approaches in image-guided radiotherapy as primary treatment for prostate cancer. A study of 2940 setup deviations in 980 MVCTs

    Energy Technology Data Exchange (ETDEWEB)

    Schiller, Kilian; Specht, Hanno; Kampfer, Severin; Duma, Marciana Nona [Technische Universitaet Muenchen Klinikum rechts der Isar, Department of Radiation Oncology, Muenchen (Germany); Petrucci, Alessia [University of Florence, Department of Radiation Oncology, Florence (Italy); Geinitz, Hans [Krankenhaus der Barmherzigen Schwestern Linz, Department of Radiation Oncology, Linz (Austria); Schuster, Tibor [Klinikum Rechts der Isar, Technische Universitaet Muenchen, Institute for Medical Statistics and Epidemiology, Muenchen (Germany)

    2014-08-15

    The goal of this study was to assess the impact of different setup approaches in image-guided radiotherapy (IMRT) of the prostatic gland. In all, 28 patients with prostate cancer were enrolled in this study. After the placement of an endorectal balloon, the planning target volume (PTV) was treated to a dose of 70 Gy in 35 fractions. A simultaneously integrated boost (SIB) of 76 Gy (2.17 Gy per fraction and per day) was delivered to a smaller target volume. All patients underwent daily prostate-aligned IGRT by megavoltage CT (MVCT). Retrospectively, three different setup approaches were evaluated by comparison to the prostate alignment: setup by skin alignment, endorectal balloon alignment, and automatic registration by bones. A total of 2,940 setup deviations were analyzed in 980 fractions. Compared to prostate alignment, skin mark alignment was associated with substantial displacements, which were ≥ 8 mm in 13 %, 5 %, and 44 % of all fractions in the lateral, longitudinal, and vertical directions, respectively. Endorectal balloon alignment yielded displacements ≥ 8 mm in 3 %, 19 %, and 1 % of all setups; and ≥ 3 mm in 27 %, 58 %, and 18 % of all fractions, respectively. For bone matching, the values were 1 %, 1 %, and 2 % and 3 %, 11 %, and 34 %, respectively. For prostate radiotherapy, setup by skin marks alone is inappropriate for patient positioning due to the fact that, during almost half of the fractions, parts of the prostate would not be targeted successfully with an 8-mm safety margin. Bone matching performs better but not sufficiently for safety margins ≤ 3 mm. Endorectal balloon matching can be combined with bone alignment to increase accuracy in the vertical direction when prostate-based setup is not available. Daily prostate alignment remains the gold standard for high-precision radiotherapy with small safety margins. (orig.) [German] Das Ziel dieser Studie bestand darin, den Einfluss verschiedener Herangehensweisen bei der Einstellung einer

  19. Study of CMOS Image Sensors for the Alignment System of the CMS Experiment

    Energy Technology Data Exchange (ETDEWEB)

    Virto, A. L.; Vila, I.; Rodrigo, T.; Matorras, F.; Figueroa, C. F.; Calvo, E.; Calderon, A.; Arce, P.; Oller, J. C.; Molinero, A.; Josa, M. I.; Fuentes, J.; Ferrando, A.; Fernandez, M. G.; Barcala, J. M.

    2002-07-01

    We report on an in-depth study made on commercial CMOS image sensors in order to determine their feasibility for beam light position detection in the CMS multipoint alignment scheme. (Author) 21 refs.

  20. MR imaging of prostate cancer; MR-Tomographie des Prostatakarzinoms

    Energy Technology Data Exchange (ETDEWEB)

    Heuck, A.; Scheidler, J.; Sommer, B.; Graser, A. [Radiologisches Zentrum Muenchen-Pasing (Germany); Mueller-Lisse, U.G. [Institut fuer Klinische Radiologie, Universitaet Muenchen (Germany); Massmann, J. [Gemeinschaftspraxis Pathologie, Muenchen (Germany)

    2003-06-01

    Accurate diagnosis and staging of prostate cancer (PC) is developing into an important health care issue in light of the high incidence of PC and the improvements in stage-adapted therapy. The purpose of this paper is to provide an overview on the current role of MR imaging and MR spectroscopy in the diagnosis and staging of PC.Material and methods Pertinent literature was searched and evaluated to collect information on current clinical indications, study techniques, diagnostic value, and limitations of magnetic resonance imaging and spectroscopy. Major indications for MR imaging of patients with supected PC are to define tumor location before biopsy when clinical or TRUS findings are inconclusive, and to provide accurate staging of histologically proven PC to ascertain effective therapy. Current MR imaging techniques for the evaluation of PC include multiplanar high-resolution T2-weighted FSE and T1-weighted SE sequences using combined endorectal and phased-array coils. Using these techniques, the reported accuracy of MR imaging for the diagnosis of extracapsular tumor extension ranges between 82 and 88% with sensitivities between 80 and 95%, and specificities between 82 and 93%. Typical MR findings of PC in different stages of disease, as well as diagnostic problems, such as chronic prostatitis, biopsy-related hemorrhage and therapy-related changes of prostatic tissue are discussed. In addition, the current perspectives and limitations of MR spectroscopy in PC are summarized. Current MR imaging techniques provide important diagnostic information in the pretherapeutic workup of PC including a high staging accuracy, and is superior to TRUS. (orig.) [German] Der Diagnostik des Prostatakarzinoms kommt wegen seiner hohen Inzidenz und den verbesserten stadienadaptierten Therapiemoeglichkeiten eine grosse Bedeutung zu. Dabei spielen bildgebende Verfahren bei den klinisch oft unzureichend diagnostizierbaren Faellen eine wesentliche Rolle fuer die praetherapeutische

  1. Image quality and cancer visibility of T2-weighted Magnetic Resonance Imaging of the prostate at 7 Tesla

    International Nuclear Information System (INIS)

    Vos, E.K.; Lagemaat, M.W.; Barentsz, J.O.; Fuetterer, J.J.; Zamecnik, P.; Roozen, H.; Maas, M.C.; Orzada, S.; Bitz, A.K.; Scheenen, T.W.J.

    2014-01-01

    To assess the image quality of T2-weighted (T2w) magnetic resonance imaging of the prostate and the visibility of prostate cancer at 7 Tesla (T). Seventeen prostate cancer patients underwent T2w imaging at 7T with only an external transmit/receive array coil. Three radiologists independently scored images for image quality, visibility of anatomical structures, and presence of artefacts. Krippendorff's alpha and weighted kappa statistics were used to assess inter-observer agreement. Visibility of prostate cancer lesions was assessed by directly linking the T2w images to the confirmed location of prostate cancer on histopathology. T2w imaging at 7T was achievable with 'satisfactory' (3/5) to 'good' (4/5) quality. Visibility of anatomical structures was predominantly scored as 'satisfactory' (3/5) and 'good' (4/5). If artefacts were present, they were mostly motion artefacts and, to a lesser extent, aliasing artefacts and noise. Krippendorff's analysis revealed an α = 0.44 between three readers for the overall image quality scores. Clinically significant cancer lesions in both peripheral zone and transition zone were visible at 7T. T2w imaging with satisfactory to good quality can be routinely acquired, and cancer lesions were visible in patients with prostate cancer at 7T using only an external transmit/receive body array coil. (orig.)

  2. Beam alignment based on two-dimensional power spectral density of a near-field image.

    Science.gov (United States)

    Wang, Shenzhen; Yuan, Qiang; Zeng, Fa; Zhang, Xin; Zhao, Junpu; Li, Kehong; Zhang, Xiaolu; Xue, Qiao; Yang, Ying; Dai, Wanjun; Zhou, Wei; Wang, Yuanchen; Zheng, Kuixing; Su, Jingqin; Hu, Dongxia; Zhu, Qihua

    2017-10-30

    Beam alignment is crucial to high-power laser facilities and is used to adjust the laser beams quickly and accurately to meet stringent requirements of pointing and centering. In this paper, a novel alignment method is presented, which employs data processing of the two-dimensional power spectral density (2D-PSD) for a near-field image and resolves the beam pointing error relative to the spatial filter pinhole directly. Combining this with a near-field fiducial mark, the operation of beam alignment is achieved. It is experimentally demonstrated that this scheme realizes a far-field alignment precision of approximately 3% of the pinhole size. This scheme adopts only one near-field camera to construct the alignment system, which provides a simple, efficient, and low-cost way to align lasers.

  3. Image-guided diagnosis of prostate cancer can increase detection of tumors

    Science.gov (United States)

    In the largest prospective study to date of image-guided technology for identifying suspicious regions of the prostate to biopsy, researchers compared the ability of this technology to detect high-risk prostate cancer with that of the current standard of

  4. Deformable image registration for image guided prostate radiotherapy

    International Nuclear Information System (INIS)

    Cassetta, Roberto; Riboldi, Marco; Baroni, Guido; Leandro, Kleber; Novaes, Paulo Eduardo; Goncalves, Vinicius; Sakuraba, Roberto; Fattori, Giovanni

    2016-01-01

    In this study, we present a CT to CBCT deformable registration method based on the ITK library. An algorithm was developed in order to explore the soft tissue information of the CT-CBCT images to perform deformable image registration (DIR), making efforts to overcome the poor signal-to-noise ratio and HU calibration issues that limits CBCT use for treatment planning purposes. Warped CT images and contours were generated and their impact in adaptive radiotherapy was evaluated by DVH analysis for photon and proton treatments. Considerable discrepancies, related to the treatment planning dose distribution, might be found due to changes in patient’s anatomy. (author)

  5. Imaging of prostate cancer local recurrences: why and how?

    International Nuclear Information System (INIS)

    Rouviere, Olivier; Lyonnet, Denis; Vitry, Thierry

    2010-01-01

    Because prostate cancer local recurrences can be efficiently treated by salvage therapies, it becomes critical to detect them early. The first alert is the rise of the prostate specific antigen (PSA) level after the post-treatment nadir, which can correspond to a distant recurrence, a local recurrence or both. This so-called biochemical failure (BF) is defined as PSA level >0.2 ng/ml after radical prostatectomy (RP) and PSA level > nadir+2 ng/ml after radiotherapy. There is no consensual definition of BF after cryotherapy, high-intensity focused ultrasound (HIFU) ablation or brachytherapy. Local recurrences after RP are treated by radiotherapy, those after radiotherapy by RP, cryotherapy, brachytherapy or HIFU ablation. Recurrences after cryotherapy or HIFU ablation can be treated by a second session or radiotherapy. Recurrences after brachytherapy are difficult to treat. In patients with BF, MRI can detect local recurrences, whatever the initial treatment was. Dynamic contrast-enhanced MRI seems particularly accurate. The role of spectroscopy remains controversial. Ultrasound-based techniques are less accurate, but this may change with the advent of ultrasonic contrast media. These recent advances in imaging may improve the outcome of salvage therapies (by improving patient selection and treatment targeting) and should open the way to focal salvage treatments in the near future. (orig.)

  6. Imaging of prostate cancer local recurrences: why and how?

    Energy Technology Data Exchange (ETDEWEB)

    Rouviere, Olivier; Lyonnet, Denis [Universite de Lyon, Lyon (France); Universite Lyon 1, Faculte de Medecine Lyon Nord (France); Service d' Imagerie Urinaire et Vasculaire, Hospices Civils de Lyon, Hopital Edouard Herriot, Lyon (France); INSERM U 556, Lyon (France); Vitry, Thierry [Service d' Imagerie Urinaire et Vasculaire, Hospices Civils de Lyon, Hopital Edouard Herriot, Lyon (France)

    2010-05-15

    Because prostate cancer local recurrences can be efficiently treated by salvage therapies, it becomes critical to detect them early. The first alert is the rise of the prostate specific antigen (PSA) level after the post-treatment nadir, which can correspond to a distant recurrence, a local recurrence or both. This so-called biochemical failure (BF) is defined as PSA level >0.2 ng/ml after radical prostatectomy (RP) and PSA level > nadir+2 ng/ml after radiotherapy. There is no consensual definition of BF after cryotherapy, high-intensity focused ultrasound (HIFU) ablation or brachytherapy. Local recurrences after RP are treated by radiotherapy, those after radiotherapy by RP, cryotherapy, brachytherapy or HIFU ablation. Recurrences after cryotherapy or HIFU ablation can be treated by a second session or radiotherapy. Recurrences after brachytherapy are difficult to treat. In patients with BF, MRI can detect local recurrences, whatever the initial treatment was. Dynamic contrast-enhanced MRI seems particularly accurate. The role of spectroscopy remains controversial. Ultrasound-based techniques are less accurate, but this may change with the advent of ultrasonic contrast media. These recent advances in imaging may improve the outcome of salvage therapies (by improving patient selection and treatment targeting) and should open the way to focal salvage treatments in the near future. (orig.)

  7. Prostate Cancer Detection Using Near Infrared Spectral Polarization Imaging

    National Research Council Canada - National Science Library

    Alfano, R. R; Wang, W. B

    2005-01-01

    .... The technique is based on the spectral and polarization properties of light scattered, absorbed and emitted from prostate cancerous and normal tissues, and contrast agents targeted to the prostate cancers. Results of finding...

  8. Confocal Microscope Alignment of Nanocrystals for Coherent Diffraction Imaging

    International Nuclear Information System (INIS)

    Beitra, Loren; Watari, Moyu; Matsuura, Takashi; Shimamoto, Naonobu; Harder, Ross; Robinson, Ian

    2010-01-01

    We have installed and tested an Olympus LEXT confocal microscope at the 34-ID-C beamline of the Advanced Photon Source (APS). The beamline is for Coherent X-ray Diffraction (CXD) experiments in which a nanometre-sized crystal is aligned inside a focussed X-ray beam. The microscope was required for three-dimensional (3D) sample alignment to get around sphere-of-confusion issues when locating Bragg peaks in reciprocal space. In this way, and by use of strategic sample preparations, we have succeeded in measuring six Bragg peaks from a single 200 nm gold crystal and obtained six projections of its internal displacement field. This enables the clear identification of stacking-fault bands within the crystal. The confocal alignment method will allow a full determination of the strain tensor provided three or more Bragg reflections from the same crystal are found.

  9. Neurient: An Algorithm for Automatic Tracing of Confluent Neuronal Images to Determine Alignment

    Science.gov (United States)

    Mitchel, J.A.; Martin, I.S.

    2013-01-01

    A goal of neural tissue engineering is the development and evaluation of materials that guide neuronal growth and alignment. However, the methods available to quantitatively evaluate the response of neurons to guidance materials are limited and/or expensive, and may require manual tracing to be performed by the researcher. We have developed an open source, automated Matlab-based algorithm, building on previously published methods, to trace and quantify alignment of fluorescent images of neurons in culture. The algorithm is divided into three phases, including computation of a lookup table which contains directional information for each image, location of a set of seed points which may lie along neurite centerlines, and tracing neurites starting with each seed point and indexing into the lookup table. This method was used to obtain quantitative alignment data for complex images of densely cultured neurons. Complete automation of tracing allows for unsupervised processing of large numbers of images. Following image processing with our algorithm, available metrics to quantify neurite alignment include angular histograms, percent of neurite segments in a given direction, and mean neurite angle. The alignment information obtained from traced images can be used to compare the response of neurons to a range of conditions. This tracing algorithm is freely available to the scientific community under the name Neurient, and its implementation in Matlab allows a wide range of researchers to use a standardized, open source method to quantitatively evaluate the alignment of dense neuronal cultures. PMID:23384629

  10. Hohlraum Target Alignment from X-ray Detector Images using Starburst Design Patterns

    International Nuclear Information System (INIS)

    Leach, R.R.; Conder, A.; Edwards, O.; Kroll, J.; Kozioziemski, B.; Mapoles, E.; McGuigan, D.; Wilhelmsen, K.

    2010-01-01

    National Ignition Facility (NIF) is a high-energy laser facility comprised of 192 laser beams focused with enough power and precision on a hydrogen-filled spherical, cryogenic target to initiate a fusion reaction. The target container, or hohlraum, must be accurately aligned to an x-ray imaging system to allow careful monitoring of the frozen fuel layer in the target. To achieve alignment, x-ray images are acquired through starburst-shaped windows cut into opposite sides of the hohlraum. When the hohlraum is in alignment, the starburst pattern pairs match nearly exactly and allow a clear view of the ice layer formation on the edge of the target capsule. During the alignment process, x-ray image analysis is applied to determine the direction and magnitude of adjustment required. X-ray detector and source are moved in concert during the alignment process. The automated pointing alignment system described here is both accurate and efficient. In this paper, we describe the control and associated image processing that enables automation of the starburst pointing alignment.

  11. Molecular imaging of tumor blood vessels in prostate cancer.

    Science.gov (United States)

    Tilki, Derya; Seitz, Michael; Singer, Bernhard B; Irmak, Ster; Stief, Christian G; Reich, Oliver; Ergün, Süleyman

    2009-05-01

    In the past three decades many efforts have been undertaken to understand the mechanisms of tumor angiogenesis. The introduction of anti-angiogenic drugs in tumor therapy during the last few years necessitates the establishment of new techniques enabling molecular imaging of tumor vascular remodelling. The determination of tumor size as commonly used is not appropriate since the extended necrosis under anti-angiogenic therapy does not necessarily result in the reduction of tumor diameter. The basis for the molecular imaging of tumor blood vessels is the remodelling of the tumor vessels under anti-angiogenic therapy which obviously occurs at an early stage and seems to be a convincing parameter. Beside the enormous progress in this field during the last few years the resolution is still not high enough to evaluate the remodelling of the micro tumor vessels. New imaging approaches combining specific molecular markers for tumor vessels with the different imaging techniques are needed to overcome this issue as exemplarily discussed for prostate cancer in this review. Molecular contrast agents targeting the vasculature will allow clinicians the visualization of vascular remodelling processes taking place under anti-angiogenic therapy and improve tumor diagnosis and follow-up.

  12. Inter- and Intra-Observer Variability in Prostate Definition With Tissue Harmonic and Brightness Mode Imaging

    International Nuclear Information System (INIS)

    Sandhu, Gurpreet Kaur; Dunscombe, Peter; Meyer, Tyler; Pavamani, Simon; Khan, Rao

    2012-01-01

    Purpose: The objective of this study was to compare the relative utility of tissue harmonic (H) and brightness (B) transrectal ultrasound (TRUS) images of the prostate by studying interobserver and intraobserver variation in prostate delineation. Methods and Materials: Ten patients with early-stage disease were randomly selected. TRUS images of prostates were acquired using B and H modes. The prostates on all images were contoured by an experienced radiation oncologist (RO) and five equally trained observers. The observers were blinded to information regarding patient and imaging mode. The volumes of prostate glands and areas of midgland slices were calculated. Volumes contoured were compared among the observers and between observer group and RO. Contours on one patient were repeated five times by four observers to evaluate the intraobserver variability. Results: A one-sample Student t-test showed the volumes outlined by five observers are in agreement (p > 0.05) with the RO. Paired Student t-test showed prostate volumes (p = 0.008) and midgland areas (p = 0.006) with H mode were significantly smaller than that with B mode. Two-factor analysis of variances showed significant interobserver variability (p < 0.001) in prostate volumes and areas. Inter- and intraobserver consistency was quantified as the standard deviation of mean volumes and areas, and concordance indices. It was found that for small glands (≤35 cc) H mode provided greater interobserver consistency; however, for large glands (≥35 cc), B mode provided more consistent estimates. Conclusions: H mode provided superior inter- and intraobserver agreement in prostate volume definition for small to medium prostates. In large glands, H mode does not exhibit any additional advantage. Although harmonic imaging has not proven advantageous for all cases, its utilization seems to be judicious for small prostates.

  13. Endorectal coil MRI and MR-spectroscopic imaging in patients with elevated serum prostate specific antigen with negative trus transrectal ultrasound guided biopsy

    Directory of Open Access Journals (Sweden)

    Farooq Ahmad Ganie

    2013-01-01

    Conclusion: Prostatic biopsy directed with endorectal coil MRI and MR-spectroscopic imaging findings in patients with elevated serum PSA and prior negative biopsy, improves the early diagnosis of prostatic carcinoma and accurate localization of prostate cancer within the gland.

  14. Improving supervised classification accuracy using non-rigid multimodal image registration: detecting prostate cancer

    Science.gov (United States)

    Chappelow, Jonathan; Viswanath, Satish; Monaco, James; Rosen, Mark; Tomaszewski, John; Feldman, Michael; Madabhushi, Anant

    2008-03-01

    Computer-aided diagnosis (CAD) systems for the detection of cancer in medical images require precise labeling of training data. For magnetic resonance (MR) imaging (MRI) of the prostate, training labels define the spatial extent of prostate cancer (CaP); the most common source for these labels is expert segmentations. When ancillary data such as whole mount histology (WMH) sections, which provide the gold standard for cancer ground truth, are available, the manual labeling of CaP can be improved by referencing WMH. However, manual segmentation is error prone, time consuming and not reproducible. Therefore, we present the use of multimodal image registration to automatically and accurately transcribe CaP from histology onto MRI following alignment of the two modalities, in order to improve the quality of training data and hence classifier performance. We quantitatively demonstrate the superiority of this registration-based methodology by comparing its results to the manual CaP annotation of expert radiologists. Five supervised CAD classifiers were trained using the labels for CaP extent on MRI obtained by the expert and 4 different registration techniques. Two of the registration methods were affi;ne schemes; one based on maximization of mutual information (MI) and the other method that we previously developed, Combined Feature Ensemble Mutual Information (COFEMI), which incorporates high-order statistical features for robust multimodal registration. Two non-rigid schemes were obtained by succeeding the two affine registration methods with an elastic deformation step using thin-plate splines (TPS). In the absence of definitive ground truth for CaP extent on MRI, classifier accuracy was evaluated against 7 ground truth surrogates obtained by different combinations of the expert and registration segmentations. For 26 multimodal MRI-WMH image pairs, all four registration methods produced a higher area under the receiver operating characteristic curve compared to that

  15. Automatic prostate MR image segmentation with sparse label propagation and domain-specific manifold regularization.

    Science.gov (United States)

    Liao, Shu; Gao, Yaozong; Shi, Yinghuan; Yousuf, Ambereen; Karademir, Ibrahim; Oto, Aytekin; Shen, Dinggang

    2013-01-01

    Automatic prostate segmentation in MR images plays an important role in prostate cancer diagnosis. However, there are two main challenges: (1) Large inter-subject prostate shape variations; (2) Inhomogeneous prostate appearance. To address these challenges, we propose a new hierarchical prostate MR segmentation method, with the main contributions lying in the following aspects: First, the most salient features are learnt from atlases based on a subclass discriminant analysis (SDA) method, which aims to find a discriminant feature subspace by simultaneously maximizing the inter-class distance and minimizing the intra-class variations. The projected features, instead of only voxel-wise intensity, will be served as anatomical signature of each voxel. Second, based on the projected features, a new multi-atlases sparse label fusion framework is proposed to estimate the prostate likelihood of each voxel in the target image from the coarse level. Third, a domain-specific semi-supervised manifold regularization method is proposed to incorporate the most reliable patient-specific information identified by the prostate likelihood map to refine the segmentation result from the fine level. Our method is evaluated on a T2 weighted prostate MR image dataset consisting of 66 patients and compared with two state-of-the-art segmentation methods. Experimental results show that our method consistently achieves the highest segmentation accuracies than other methods under comparison.

  16. Five-year follow-up using a prostate stent as fiducial in image-guided radiotherapy of prostate cancer.

    Science.gov (United States)

    Carl, Jesper; Sander, Lotte

    2015-06-01

    To report results from the five-year follow-up on a previously reported study using image-guided radiotherapy (IGRT) of localized or locally advanced prostate cancer (PC) and a removable prostate stent as fiducial. Patients with local or locally advanced PC were treated using five-field 3D conformal radiotherapy (3DRT). The clinical target volumes (CTV) were treated to 78 Gy in 39 fractions using daily on-line image guidance (IG). Late genito-urinary (GU) and gastro-intestinal (GI) toxicities were scored using the radiotherapy oncology group (RTOG) score and the common toxicity score of adverse events (CTC) score. Urinary symptoms were also scored using the international prostate symptom score (IPSS). Median observation time was 5.4 year. Sixty-two of the 90 patients from the original study cohort were eligible for toxicity assessment. Overall survival, cancer-specific survival and biochemical freedom from failure were 85%, 96% and 80%, respectively at five years after radiotherapy. Late toxicity GU and GI RTOG scores≥2 were 5% and 0%. Comparing pre- and post-radiotherapy IPSS scores indicate that development in urinary symptoms after radiotherapy may be complex. Prostate image-guided radiotherapy using a prostate stent demonstrated survival data comparable with recently published data. GU and GI toxicities at five-year follow-up were low and comparable to the lowest toxicity rates reported. These findings support that the precision of the prostate stent technique is at least as good as other techniques. IPSS revealed a complex development in urinary symptoms after radiotherapy.

  17. Automated and Adaptable Quantification of Cellular Alignment from Microscopic Images for Tissue Engineering Applications

    Science.gov (United States)

    Xu, Feng; Beyazoglu, Turker; Hefner, Evan; Gurkan, Umut Atakan

    2011-01-01

    Cellular alignment plays a critical role in functional, physical, and biological characteristics of many tissue types, such as muscle, tendon, nerve, and cornea. Current efforts toward regeneration of these tissues include replicating the cellular microenvironment by developing biomaterials that facilitate cellular alignment. To assess the functional effectiveness of the engineered microenvironments, one essential criterion is quantification of cellular alignment. Therefore, there is a need for rapid, accurate, and adaptable methodologies to quantify cellular alignment for tissue engineering applications. To address this need, we developed an automated method, binarization-based extraction of alignment score (BEAS), to determine cell orientation distribution in a wide variety of microscopic images. This method combines a sequenced application of median and band-pass filters, locally adaptive thresholding approaches and image processing techniques. Cellular alignment score is obtained by applying a robust scoring algorithm to the orientation distribution. We validated the BEAS method by comparing the results with the existing approaches reported in literature (i.e., manual, radial fast Fourier transform-radial sum, and gradient based approaches). Validation results indicated that the BEAS method resulted in statistically comparable alignment scores with the manual method (coefficient of determination R2=0.92). Therefore, the BEAS method introduced in this study could enable accurate, convenient, and adaptable evaluation of engineered tissue constructs and biomaterials in terms of cellular alignment and organization. PMID:21370940

  18. Visualizing the prostate gland by MR imaging in young and old mice.

    Directory of Open Access Journals (Sweden)

    Murali Ravoori

    Full Text Available Prostate imaging requires optimization in young and old mouse models. We tested which MR sequences and field strengths best depict the prostate gland in young and old mice; and, whether prostate MR signal, size, and architecture change with age.Magnetic resonance imaging (MRI of the prostate of young (2 months and old (18 months male nude mice (n = 6 was performed at 4.7 and 7 T and SCID mice (n = 6 at 7 T field strengths, using T1, fat suppressed T1, DWI, T2, fat suppressed T2, as well as T2-based- and proton density-based Dixon "water only" sequences. Images were ranked for best overall sequence for prostate visualization, prostate delineation, and quality of fat suppression. Prostate volume and signal characteristics were compared and histology was performed.T2-based-Dixon "water only" images ranked best overall for prostate visualization and delineation as well as fat suppression (n = 6, P<0.001 at both 4.7 T and 7 T in nude and 7T in SCID mice. Evaluated in nude mice, T2-based Dixon "water only" had greater prostate CNR and lower fat SNR at 7 T than 4.7 T (P<0.001. Prostate volume was less in older than younger mice (n = 6, P<0.02 nude mice; n = 6, P<0.002 SCID mice. Prostate T2 FSE as well as proton density-based and T2-based-Dixon "water only" signal intensity was higher in younger than older mice (P<0.001 nude mice; P<0.01 SCID mice both at 4.7 and 7 T. This corresponded to an increase in glandular hyperplasia in older mice by histology (P<0.01, n = 6.T2-based Dixon "water only" images best depict the mouse prostate in young and old nude mice at 4.7 and 7 T. The mouse prostate decreases in size with age. The decrease in T2 and T2-based Dixon "water only" signal with age corresponds with glandular hyperplasia. Findings suggest age should be an important determinant when choosing models of prostate biology and disease.

  19. Vision Servo Motion Control and Error Analysis of a Coplanar XXY Stage for Image Alignment Motion

    Directory of Open Access Journals (Sweden)

    Hau-Wei Lee

    2013-01-01

    Full Text Available In recent years, as there is demand for smart mobile phones with touch panels, the alignment/compensation system of alignment stage with vision servo control has also increased. Due to the fact that the traditional stacked-type XYθ stage has cumulative errors of assembly and it is heavy, it has been gradually replaced by the coplanar stage characterized by three actuators on the same plane with three degrees of freedom. The simplest image alignment mode uses two cameras as the equipments for feedback control, and the work piece is placed on the working stage. The work piece is usually engraved/marked. After the cameras capture images and when the position of the mark in the camera is obtained by image processing, the mark can be moved to the designated position in the camera by moving the stage and using alignment algorithm. This study used a coplanar XXY stage with 1 μm positioning resolution. Due to the fact that the resolution of the camera is about 3.75 μm per pixel, thus a subpixel technology is used, and the linear and angular alignment repeatability of the alignment system can achieve 1 μm and 5 arcsec, respectively. The visual servo motion control for alignment motion is completed within 1 second using the coplanar XXY stage.

  20. Prostate Ultrasound

    Medline Plus

    Full Text Available ... about radiology? Share your patient story here Images × Image Gallery Radiologist and patient consultation. View full size with caption Related Articles and Media Benign Prostatic Hyperplasia (BPH) (Enlargement of the Prostate) ...

  1. FLIM-FRET image analysis of tryptophan in prostate cancer cells

    Science.gov (United States)

    Periasamy, Ammasi; Alam, Shagufta R.; Svindrych, Zdenek; Wallrabe, Horst

    2017-07-01

    A region of interest (ROI) based quantitative FLIM-FRET image analysis is developed to quantitate the autofluorescence signals of the essential amino acid tryptophan as a biomarker to investigate the metabolism in prostate cancer cells.

  2. Bladder outlet obstruction due to a small midline prostatic cyst - diagnostic imaging and interventional radiological treatment

    International Nuclear Information System (INIS)

    Hueppe, T.; Kopka, L.; Friedrich, M.; Kuehn, M.

    1992-01-01

    We describe a rare case of a bladder outlet obstruction due to a midline prostatic cyst. In the following clinical apperance, diagnostic imaging and therapy by CT-guided punction are reported. Differential diagnosis and therapy are discussed. (orig.) [de

  3. Prostate cancer

    International Nuclear Information System (INIS)

    Murphy, G.P.; Kuss, R.; Khoury, S.; Chatelain, C.; Denis, L.

    1987-01-01

    This book contains over 70 selections. Some of the titles are: Place of the Computed Tomography in the Staging of Prostatic Cancer; Magnetic Resonance Imaging (MRI) in Staging of the Prostatic Cancer; Magnetic Resonance Imaging of the Prostate; Long-Term Results in Radiotherapy of Prostatic Cancer; Interstitial Irradiation Using I-125 Seeds; and Treatment of Cancer of the Prostate by Use of Physiotherapy: Long-Term Results

  4. Prostate cancer

    Energy Technology Data Exchange (ETDEWEB)

    Murphy, G.P.; Kuss, R., Khoury, S.; Chatelain, C.; Denis, L.

    1987-01-01

    This book contains over 70 selections. Some of the titles are: Place of the Computed Tomography in the Staging of Prostatic Cancer; Magnetic Resonance Imaging (MRI) in Staging of the Prostatic Cancer; Magnetic Resonance Imaging of the Prostate; Long-Term Results in Radiotherapy of Prostatic Cancer; Interstitial Irradiation Using I-125 Seeds; and Treatment of Cancer of the Prostate by Use of Physiotherapy: Long-Term Results.

  5. Real-time virtual sonography for navigation during targeted prostate biopsy using magnetic resonance imaging data

    International Nuclear Information System (INIS)

    Miyagawa, Tomoaki; Ishikawa, Satoru; Kimura, Tomokazu; Suetomi, Takahiro; Tsutsumi, Masakazu; Irie, Toshiyuki; Kondoh, Masanao; Mitake, Tsuyoshi

    2010-01-01

    The objective of this study was to evaluate the effectiveness of the medical navigation technique, namely, Real-time Virtual Sonography (RVS), for targeted prostate biopsy. Eighty-five patients with suspected prostate cancer lesions using magnetic resonance imaging (MRI) were included in this study. All selected patients had at least one negative result on the previous transrectal biopsies. The acquired MRI volume data were loaded onto a personal computer installed with RVS software, which registers the volumes between MRI and real-time ultrasound data for real-time display. The registered MRI images were displayed adjacent to the ultrasonographic sagittal image on the same computer monitor. The suspected lesions on T2-weighted images were marked with a red circle. At first suspected lesions were biopsied transperineally under real-time navigation with RVS and then followed by the conventional transrectal and transperineal biopsy under spinal anesthesia. The median age of the patients was 69 years (56-84 years), and the prostate-specific antigen level and prostate volume were 9.9 ng/mL (4.0-34.2) and 37.2 mL (18-141), respectively. Prostate cancer was detected in 52 patients (61%). The biopsy specimens obtained using RVS revealed 45/52 patients (87%) positive for prostate cancer. A total of 192 biopsy cores were obtained using RVS. Sixty-two of these (32%) were positive for prostate cancer, whereas conventional random biopsy revealed cancer only in 75/833 (9%) cores (P<0.01). Targeted prostate biopsy with RVS is very effective to diagnose lesions detected with MRI. This technique only requires additional computer and RVS software and thus is cost-effective. Therefore, RVS-guided prostate biopsy has great potential for better management of prostate cancer patients. (author)

  6. Optimal image alignment with random projections of manifolds: algorithm and geometric analysis.

    Science.gov (United States)

    Kokiopoulou, Effrosyni; Kressner, Daniel; Frossard, Pascal

    2011-06-01

    This paper addresses the problem of image alignment based on random measurements. Image alignment consists of estimating the relative transformation between a query image and a reference image. We consider the specific problem where the query image is provided in compressed form in terms of linear measurements captured by a vision sensor. We cast the alignment problem as a manifold distance minimization problem in the linear subspace defined by the measurements. The transformation manifold that represents synthesis of shift, rotation, and isotropic scaling of the reference image can be given in closed form when the reference pattern is sparsely represented over a parametric dictionary. We show that the objective function can then be decomposed as the difference of two convex functions (DC) in the particular case where the dictionary is built on Gaussian functions. Thus, the optimization problem becomes a DC program, which in turn can be solved globally by a cutting plane method. The quality of the solution is typically affected by the number of random measurements and the condition number of the manifold that describes the transformations of the reference image. We show that the curvature, which is closely related to the condition number, remains bounded in our image alignment problem, which means that the relative transformation between two images can be determined optimally in a reduced subspace.

  7. Accurate and robust brain image alignment using boundary-based registration.

    Science.gov (United States)

    Greve, Douglas N; Fischl, Bruce

    2009-10-15

    The fine spatial scales of the structures in the human brain represent an enormous challenge to the successful integration of information from different images for both within- and between-subject analysis. While many algorithms to register image pairs from the same subject exist, visual inspection shows that their accuracy and robustness to be suspect, particularly when there are strong intensity gradients and/or only part of the brain is imaged. This paper introduces a new algorithm called Boundary-Based Registration, or BBR. The novelty of BBR is that it treats the two images very differently. The reference image must be of sufficient resolution and quality to extract surfaces that separate tissue types. The input image is then aligned to the reference by maximizing the intensity gradient across tissue boundaries. Several lower quality images can be aligned through their alignment with the reference. Visual inspection and fMRI results show that BBR is more accurate than correlation ratio or normalized mutual information and is considerably more robust to even strong intensity inhomogeneities. BBR also excels at aligning partial-brain images to whole-brain images, a domain in which existing registration algorithms frequently fail. Even in the limit of registering a single slice, we show the BBR results to be robust and accurate.

  8. Diagnostic Accuracy of Multiparametric Magnetic Resonance Imaging and Fusion Guided Targeted Biopsy Evaluated by Transperineal Template Saturation Prostate Biopsy for the Detection and Characterization of Prostate Cancer.

    Science.gov (United States)

    Mortezavi, Ashkan; Märzendorfer, Olivia; Donati, Olivio F; Rizzi, Gianluca; Rupp, Niels J; Wettstein, Marian S; Gross, Oliver; Sulser, Tullio; Hermanns, Thomas; Eberli, Daniel

    2018-02-21

    We evaluated the diagnostic accuracy of multiparametric magnetic resonance imaging and multiparametric magnetic resonance imaging/transrectal ultrasound fusion guided targeted biopsy against that of transperineal template saturation prostate biopsy to detect prostate cancer. We retrospectively analyzed the records of 415 men who consecutively presented for prostate biopsy between November 2014 and September 2016 at our tertiary care center. Multiparametric magnetic resonance imaging was performed using a 3 Tesla device without an endorectal coil, followed by transperineal template saturation prostate biopsy with the BiopSee® fusion system. Additional fusion guided targeted biopsy was done in men with a suspicious lesion on multiparametric magnetic resonance imaging, defined as Likert score 3 to 5. Any Gleason pattern 4 was defined as clinically significant prostate cancer. The detection rates of multiparametric magnetic resonance imaging and fusion guided targeted biopsy were compared with the detection rate of transperineal template saturation prostate biopsy using the McNemar test. We obtained a median of 40 (range 30 to 55) and 3 (range 2 to 4) transperineal template saturation prostate biopsy and fusion guided targeted biopsy cores, respectively. Of the 124 patients (29.9%) without a suspicious lesion on multiparametric magnetic resonance imaging 32 (25.8%) were found to have clinically significant prostate cancer on transperineal template saturation prostate biopsy. Of the 291 patients (70.1%) with a Likert score of 3 to 5 clinically significant prostate cancer was detected in 129 (44.3%) by multiparametric magnetic resonance imaging fusion guided targeted biopsy, in 176 (60.5%) by transperineal template saturation prostate biopsy and in 187 (64.3%) by the combined approach. Overall 58 cases (19.9%) of clinically significant prostate cancer would have been missed if fusion guided targeted biopsy had been performed exclusively. The sensitivity of

  9. Phosphorus magnetic resonance spectroscopic imaging at 7 T in patients with prostate cancer.

    Science.gov (United States)

    Lagemaat, Miriam W; Vos, Eline K; Maas, Marnix C; Bitz, Andreas K; Orzada, Stephan; van Uden, Mark J; Kobus, Thiele; Heerschap, Arend; Scheenen, Tom W J

    2014-05-01

    The aim of this study was to identify characteristics of phosphorus (P) spectra of the human prostate and to investigate changes of individual phospholipid metabolites in prostate cancer through in vivo P magnetic resonance spectroscopic imaging (MRSI) at 7 T. In this institutional review board-approved study, 15 patients with biopsy-proven prostate cancer underwent T2-weighted magnetic resonance imaging and 3-dimensional P MRSI at 7 T. Voxels were selected at the tumor location, in normal-appearing peripheral zone tissue, normal-appearing transition zone tissue, and in the base of the prostate close to the seminal vesicles. Phosphorus metabolite ratios were determined and compared between tissue types. Signals of phosphoethanolamine (PE) and phosphocholine (PC) were present and well resolved in most P spectra in the prostate. Glycerophosphocholine signals were observable in 43% of the voxels in malignant tissue, but in only 10% of the voxels in normal-appearing tissue away from the seminal vesicles. In many spectra, independent of tissue type, 2 peaks resonated in the chemical shift range of inorganic phosphate, possibly representing 2 separate pH compartments. The PC/PE ratio in the seminal vesicles was highly elevated compared with the prostate in 5 patients. A considerable overlap of P metabolite ratios was found between prostate cancer and normal-appearing prostate tissue, preventing direct discrimination of these tissues. The only 2 patients with high Gleason scores tumors (≥4+5) presented with high PC and glycerophosphocholine levels in their cancer lesions. Phosphorus MRSI at 7 T shows distinct features of phospholipid metabolites in the prostate gland and its surrounding structures. In this exploratory study, no differences in P metabolite ratios were observed between prostate cancer and normal-appearing prostate tissue possibly because of the partial volume effects of small tumor foci in large MRSI voxels.

  10. Automated Registration of Multimodal Optic Disc Images: Clinical Assessment of Alignment Accuracy.

    Science.gov (United States)

    Ng, Wai Siene; Legg, Phil; Avadhanam, Venkat; Aye, Kyaw; Evans, Steffan H P; North, Rachel V; Marshall, Andrew D; Rosin, Paul; Morgan, James E

    2016-04-01

    To determine the accuracy of automated alignment algorithms for the registration of optic disc images obtained by 2 different modalities: fundus photography and scanning laser tomography. Images obtained with the Heidelberg Retina Tomograph II and paired photographic optic disc images of 135 eyes were analyzed. Three state-of-the-art automated registration techniques Regional Mutual Information, rigid Feature Neighbourhood Mutual Information (FNMI), and nonrigid FNMI (NRFNMI) were used to align these image pairs. Alignment of each composite picture was assessed on a 5-point grading scale: "Fail" (no alignment of vessels with no vessel contact), "Weak" (vessels have slight contact), "Good" (vessels with 50% contact), and "Excellent" (complete alignment). Custom software generated an image mosaic in which the modalities were interleaved as a series of alternate 5×5-pixel blocks. These were graded independently by 3 clinically experienced observers. A total of 810 image pairs were assessed. All 3 registration techniques achieved a score of "Good" or better in >95% of the image sets. NRFNMI had the highest percentage of "Excellent" (mean: 99.6%; range, 95.2% to 99.6%), followed by Regional Mutual Information (mean: 81.6%; range, 86.3% to 78.5%) and FNMI (mean: 73.1%; range, 85.2% to 54.4%). Automated registration of optic disc images by different modalities is a feasible option for clinical application. All 3 methods provided useful levels of alignment, but the NRFNMI technique consistently outperformed the others and is recommended as a practical approach to the automated registration of multimodal disc images.

  11. Inter- and intra-observer variability in prostate definition with tissue harmonic and brightness mode imaging.

    Science.gov (United States)

    Sandhu, Gurpreet Kaur; Dunscombe, Peter; Meyer, Tyler; Pavamani, Simon; Khan, Rao

    2012-01-01

    The objective of this study was to compare the relative utility of tissue harmonic (H) and brightness (B) transrectal ultrasound (TRUS) images of the prostate by studying interobserver and intraobserver variation in prostate delineation. Ten patients with early-stage disease were randomly selected. TRUS images of prostates were acquired using B and H modes. The prostates on all images were contoured by an experienced radiation oncologist (RO) and five equally trained observers. The observers were blinded to information regarding patient and imaging mode. The volumes of prostate glands and areas of midgland slices were calculated. Volumes contoured were compared among the observers and between observer group and RO. Contours on one patient were repeated five times by four observers to evaluate the intraobserver variability. A one-sample Student t-test showed the volumes outlined by five observers are in agreement (p > 0.05) with the RO. Paired Student t-test showed prostate volumes (p = 0.008) and midgland areas (p = 0.006) with H mode were significantly smaller than that with B mode. Two-factor analysis of variances showed significant interobserver variability (p standard deviation of mean volumes and areas, and concordance indices. It was found that for small glands (≤35 cc) H mode provided greater interobserver consistency; however, for large glands (≥35 cc), B mode provided more consistent estimates. H mode provided superior inter- and intraobserver agreement in prostate volume definition for small to medium prostates. In large glands, H mode does not exhibit any additional advantage. Although harmonic imaging has not proven advantageous for all cases, its utilization seems to be judicious for small prostates. Crown Copyright © 2012. Published by Elsevier Inc. All rights reserved.

  12. Is MR imaging useful for detecting prostate cancer in cases requiring repeat biopsy?. Presidential award proceedings

    International Nuclear Information System (INIS)

    Ito, Hirotoshi; Takahata, Akiko; Goto, Mariko; Masunami, Terutoshi; Yuen, Sachiko; Yamada, Kei; Nishimura, Tsunehiko

    2007-01-01

    The purpose of this study was to evaluate the usefulness of magnetic resonance (MR) imaging in detecting prostate cancer in cases requiring repeat biopsy. Twenty patients with negative first prostate biopsy were evaluated by T2-weighted images (T 2 W), diffusion weighted image (DWI), and contrast-enhanced dynamic MRI at 1.5T prior to repeat biopsy. Eleven of the 20 also underwent MR imaging before initial biopsy. Cancer criteria were defined as an area of low signal intensity on T 2 W, high signal intensity on DWI, and early enhancement on dynamic MR imaging. We compared MR imaging findings with biopsy results. Prostate cancer was detected by repeat biopsy in nine of 20 patients. MR imaging demonstrated the cancer lesion in seven of the 9 patients whose biopsies were positive for cancer. MR imaging of 5 patients whose biopsies showed cancer also demonstrated cancer lesion previous to initial biopsy. Most cancers were detected in the anterior, apex, and far lateral areas. False-negative cases were low-grade cancers and had a few positive biopsy cores. In patients with repeat prostate biopsy, prior MR imaging may be valuable for detecting and localizing prostate cancer. (author)

  13. Alignment of CT images of skull dysmorphology using anatomy-based perpendicular axes

    International Nuclear Information System (INIS)

    Yoo, Sun K; Kim, Yong O; Kim, Hee-Joung; Kim, Nam H; Jang, Young Beom; Kim, Kee-Deog; Lee, Hye-Yeon

    2003-01-01

    Rigid body registration of 3D CT scans, based on manual identification of homologous landmarks, is useful for the visual analysis of skull dysmorphology. In this paper, a robust and simple alignment method was proposed to allow for the comparison of skull morphologies, within and between individuals with craniofacial anomalies, based on 3D CT scans, and the minimum number of anatomical landmarks, under rigidity and uniqueness constraints. Three perpendicular axes, extracted from anatomical landmarks, define the absolute coordinate system, through a rigid body transformation, to align multiple CT images for different patients and acquisition times. The accuracy of the alignment method depends on the accuracy of the localized landmarks and target points. The numerical simulation generalizes the accuracy requirements of the alignment method. Experiments using a human dried skull specimen, and ten sets of skull CT images (the pre- and post-operative CT scans of four plagiocephaly, and one fibrous dysplasia patients), demonstrated the feasibility of the technique in clinical practice

  14. Simultaneous cell tracking and image alignment in 3D CLSM imagery of growing arabidopsis thaliana sepals

    NARCIS (Netherlands)

    Fick, R.H.J.; Fedorov, D.; Roeder, A.H.K.; Manjunath, B.S.

    2013-01-01

    In this research we propose a combined cell matching and image alignment method for tracking cells based on their nuclear locations in 3D fluorescent Confocal Laser Scanning Microscopy (CLSM) image sequences. We then apply it to study the cell division pattern in the developing sepal of the small

  15. Image-robot coupling for the prostate brachytherapy

    International Nuclear Information System (INIS)

    Coelen, V.; Lartigau, E.; Merzouki, R.

    2009-01-01

    The results allows to contemplate a robot use in the prostate brachytherapy but equally in other applications such prostate biopsy. The tests to come are going to be directed towards on the use of a prostate phantom in order to calibrate the ultrasonography. thereafter, we contemplate the conception of an intelligent gripping system placed on the robot arm and allowing a good control in closed loop of the brachytherapy needle placement and allowing the setting up of an online monitoring. (N.C.)

  16. Alignment of the Measurement Scale Mark during Immersion Hydrometer Calibration Using an Image Processing System

    OpenAIRE

    Pe?a-Perez, Luis Manuel; Pedraza-Ortega, Jesus Carlos; Ramos-Arreguin, Juan Manuel; Arriaga, Saul Tovar; Fernandez, Marco Antonio Aceves; Becerra, Luis Omar; Hurtado, Efren Gorrostieta; Vargas-Soto, Jose Emilio

    2013-01-01

    The present work presents an improved method to align the measurement scale mark in an immersion hydrometer calibration system of CENAM, the National Metrology Institute (NMI) of Mexico, The proposed method uses a vision system to align the scale mark of the hydrometer to the surface of the liquid where it is immersed by implementing image processing algorithms. This approach reduces the variability in the apparent mass determination during the hydrostatic weighing in the calibration process,...

  17. Alignment of the measurement scale mark during immersion hydrometer calibration using an image processing system.

    Science.gov (United States)

    Peña-Perez, Luis Manuel; Pedraza-Ortega, Jesus Carlos; Ramos-Arreguin, Juan Manuel; Arriaga, Saul Tovar; Fernandez, Marco Antonio Aceves; Becerra, Luis Omar; Hurtado, Efren Gorrostieta; Vargas-Soto, Jose Emilio

    2013-10-24

    The present work presents an improved method to align the measurement scale mark in an immersion hydrometer calibration system of CENAM, the National Metrology Institute (NMI) of Mexico, The proposed method uses a vision system to align the scale mark of the hydrometer to the surface of the liquid where it is immersed by implementing image processing algorithms. This approach reduces the variability in the apparent mass determination during the hydrostatic weighing in the calibration process, therefore decreasing the relative uncertainty of calibration.

  18. Poster - 48: Clinical assessment of ExacTrac stereoscopic imaging of spine alignment for lung SBRT

    International Nuclear Information System (INIS)

    Sattarivand, Mike; Summers, Clare; Robar, James

    2016-01-01

    Purpose: To evaluate the validity of using spine as a surrogate for tumor positioning with ExacTrac stereoscopic imaging in lung stereotactic body radiation therapy (SBRT). Methods: Using the Novalis ExacTrac x-ray system, 39 lung SBRT patients (182 treatments) were aligned before treatment with 6 degrees (6D) of freedom couch (3 translations, 3 rotations) based on spine matching on stereoscopic images. The couch was shifted to treatment isocenter and pre-treatment CBCT was performed based on a soft tissue match around tumor volume. The CBCT data were used to measure residual errors following ExacTrac alignment. The thresholds for re-aligning the patients based on CBCT were 3mm shift or 3° rotation (in any 6D). In order to evaluate the effect of tumor location on residual errors, correlations between tumor distance from spine and individual residual errors were calculated. Results: Residual errors were up to 0.5±2.4mm. Using 3mm/3° thresholds, 80/182 (44%) of the treatments required re-alignment based on CBCT soft tissue matching following ExacTrac spine alignment. Most mismatches were in sup-inf, ant-post, and roll directions which had larger standard deviations. No correlation was found between tumor distance from spine and individual residual errors. Conclusion: ExacTrac stereoscopic imaging offers a quick pre-treatment patient alignment. However, bone matching based on spine is not reliable for aligning lung SBRT patients who require soft tissue image registration from CBCT. Spine can be a poor surrogate for lung SBRT patient alignment even for proximal tumor volumes.

  19. Poster - 48: Clinical assessment of ExacTrac stereoscopic imaging of spine alignment for lung SBRT

    Energy Technology Data Exchange (ETDEWEB)

    Sattarivand, Mike; Summers, Clare; Robar, James [Nova Scotia Cancer Centre, Nova Scotia Cancer Centre, Nova Scotia Cancer Centre (Canada)

    2016-08-15

    Purpose: To evaluate the validity of using spine as a surrogate for tumor positioning with ExacTrac stereoscopic imaging in lung stereotactic body radiation therapy (SBRT). Methods: Using the Novalis ExacTrac x-ray system, 39 lung SBRT patients (182 treatments) were aligned before treatment with 6 degrees (6D) of freedom couch (3 translations, 3 rotations) based on spine matching on stereoscopic images. The couch was shifted to treatment isocenter and pre-treatment CBCT was performed based on a soft tissue match around tumor volume. The CBCT data were used to measure residual errors following ExacTrac alignment. The thresholds for re-aligning the patients based on CBCT were 3mm shift or 3° rotation (in any 6D). In order to evaluate the effect of tumor location on residual errors, correlations between tumor distance from spine and individual residual errors were calculated. Results: Residual errors were up to 0.5±2.4mm. Using 3mm/3° thresholds, 80/182 (44%) of the treatments required re-alignment based on CBCT soft tissue matching following ExacTrac spine alignment. Most mismatches were in sup-inf, ant-post, and roll directions which had larger standard deviations. No correlation was found between tumor distance from spine and individual residual errors. Conclusion: ExacTrac stereoscopic imaging offers a quick pre-treatment patient alignment. However, bone matching based on spine is not reliable for aligning lung SBRT patients who require soft tissue image registration from CBCT. Spine can be a poor surrogate for lung SBRT patient alignment even for proximal tumor volumes.

  20. Improving PET spatial resolution and detectability for prostate cancer imaging

    International Nuclear Information System (INIS)

    Bal, H; Guerin, L; Casey, M E; Conti, M; Eriksson, L; Michel, C; Fanti, S; Pettinato, C; Adler, S; Choyke, P

    2014-01-01

    Prostate cancer, one of the most common forms of cancer among men, can benefit from recent improvements in positron emission tomography (PET) technology. In particular, better spatial resolution, lower noise and higher detectability of small lesions could be greatly beneficial for early diagnosis and could provide a strong support for guiding biopsy and surgery. In this article, the impact of improved PET instrumentation with superior spatial resolution and high sensitivity are discussed, together with the latest development in PET technology: resolution recovery and time-of-flight reconstruction. Using simulated cancer lesions, inserted in clinical PET images obtained with conventional protocols, we show that visual identification of the lesions and detectability via numerical observers can already be improved using state of the art PET reconstruction methods. This was achieved using both resolution recovery and time-of-flight reconstruction, and a high resolution image with 2 mm pixel size. Channelized Hotelling numerical observers showed an increase in the area under the LROC curve from 0.52 to 0.58. In addition, a relationship between the simulated input activity and the area under the LROC curve showed that the minimum detectable activity was reduced by more than 23%. (paper)

  1. Multiparametric Magnetic Resonance Imaging for Discriminating Low-Grade From High-Grade Prostate Cancer

    NARCIS (Netherlands)

    Vos, E.K.; Kobus, T.; Litjens, G.J.S.; Hambrock, T.; Hulsbergen-van de Kaa, C.A.; Barentsz, J.O.; Maas, M.C.; Scheenen, T.W.J.

    2015-01-01

    The aim of this study was to determine and validate the optimal combination of parameters derived from 3-T diffusion-weighted imaging, dynamic contrast-enhanced imaging, and magnetic resonance (MR) spectroscopic imaging for discriminating low-grade from high-grade prostate cancer (PCa).The study was

  2. Automated, feature-based image alignment for high-resolution imaging mass spectrometry of large biological samples

    NARCIS (Netherlands)

    Broersen, A.; Liere, van R.; Altelaar, A.F.M.; Heeren, R.M.A.; McDonnell, L.A.

    2008-01-01

    High-resolution imaging mass spectrometry of large biological samples is the goal of several research groups. In mosaic imaging, the most common method, the large sample is divided into a mosaic of small areas that are then analyzed with high resolution. Here we present an automated alignment

  3. Fitting-free algorithm for efficient quantification of collagen fiber alignment in SHG imaging applications.

    Science.gov (United States)

    Hall, Gunnsteinn; Liang, Wenxuan; Li, Xingde

    2017-10-01

    Collagen fiber alignment derived from second harmonic generation (SHG) microscopy images can be important for disease diagnostics. Image processing algorithms are needed to robustly quantify the alignment in images with high sensitivity and reliability. Fourier transform (FT) magnitude, 2D power spectrum, and image autocorrelation have previously been used to extract fiber information from images by assuming a certain mathematical model (e.g. Gaussian distribution of the fiber-related parameters) and fitting. The fitting process is slow and fails to converge when the data is not Gaussian. Herein we present an efficient constant-time deterministic algorithm which characterizes the symmetricity of the FT magnitude image in terms of a single parameter, named the fiber alignment anisotropy R ranging from 0 (randomized fibers) to 1 (perfect alignment). This represents an important improvement of the technology and may bring us one step closer to utilizing the technology for various applications in real time. In addition, we present a digital image phantom-based framework for characterizing and validating the algorithm, as well as assessing the robustness of the algorithm against different perturbations.

  4. SU-F-T-42: MRI and TRUS Image Fusion as a Mode of Generating More Accurate Prostate Contours

    Energy Technology Data Exchange (ETDEWEB)

    Petronek, M; Purysko, A; Balik, S; Ciezki, J; Klein, E; Wilkinson, D [Cleveland Clinic Foundation, Cleveland, OH (United States)

    2016-06-15

    Purpose: Transrectal Ultrasound (TRUS) imaging is utilized intra-operatively for LDR permanent prostate seed implant treatment planning. Prostate contouring with TRUS can be challenging at the apex and base. This study attempts to improve accuracy of prostate contouring with MRI-TRUS fusion to prevent over- or under-estimation of the prostate volume. Methods: 14 patients with previous MRI guided prostate biopsy and undergone an LDR permanent prostate seed implant have been selected. The prostate was contoured on the MRI images (1 mm slice thickness) by a radiologist. The prostate was also contoured on TRUS images (5 mm slice thickness) during LDR procedure by a urologist. MRI and TRUS images were rigidly fused manually and the prostate contours from MRI and TRUS were compared using Dice similarity coefficient, percentage volume difference and length, height and width differences. Results: The prostate volume was overestimated by 8 ± 18% (range: 34% to −25%) in TRUS images compared to MRI. The mean Dice was 0.77 ± 0.09 (range: 0.53 to 0.88). The mean difference (TRUS-MRI) in the prostate width was 0 ± 4 mm (range: −11 to 5 mm), height was −3 ± 6 mm (range: −13 to 6 mm) and length was 6 ± 6 (range: −10 to 16 mm). Prostate was overestimated with TRUS imaging at the base for 6 cases (mean: 8 ± 4 mm and range: 5 to 14 mm), at the apex for 6 cases (mean: 11 ± 3 mm and range: 5 to 15 mm) and 1 case was underestimated at both base and apex by 4 mm. Conclusion: Use of intra-operative TRUS and MRI image fusion can help to improve the accuracy of prostate contouring by accurately accounting for prostate over- or under-estimations, especially at the base and apex. The mean amount of discrepancy is within a range that is significant for LDR sources.

  5. SU-F-T-42: MRI and TRUS Image Fusion as a Mode of Generating More Accurate Prostate Contours

    International Nuclear Information System (INIS)

    Petronek, M; Purysko, A; Balik, S; Ciezki, J; Klein, E; Wilkinson, D

    2016-01-01

    Purpose: Transrectal Ultrasound (TRUS) imaging is utilized intra-operatively for LDR permanent prostate seed implant treatment planning. Prostate contouring with TRUS can be challenging at the apex and base. This study attempts to improve accuracy of prostate contouring with MRI-TRUS fusion to prevent over- or under-estimation of the prostate volume. Methods: 14 patients with previous MRI guided prostate biopsy and undergone an LDR permanent prostate seed implant have been selected. The prostate was contoured on the MRI images (1 mm slice thickness) by a radiologist. The prostate was also contoured on TRUS images (5 mm slice thickness) during LDR procedure by a urologist. MRI and TRUS images were rigidly fused manually and the prostate contours from MRI and TRUS were compared using Dice similarity coefficient, percentage volume difference and length, height and width differences. Results: The prostate volume was overestimated by 8 ± 18% (range: 34% to −25%) in TRUS images compared to MRI. The mean Dice was 0.77 ± 0.09 (range: 0.53 to 0.88). The mean difference (TRUS-MRI) in the prostate width was 0 ± 4 mm (range: −11 to 5 mm), height was −3 ± 6 mm (range: −13 to 6 mm) and length was 6 ± 6 (range: −10 to 16 mm). Prostate was overestimated with TRUS imaging at the base for 6 cases (mean: 8 ± 4 mm and range: 5 to 14 mm), at the apex for 6 cases (mean: 11 ± 3 mm and range: 5 to 15 mm) and 1 case was underestimated at both base and apex by 4 mm. Conclusion: Use of intra-operative TRUS and MRI image fusion can help to improve the accuracy of prostate contouring by accurately accounting for prostate over- or under-estimations, especially at the base and apex. The mean amount of discrepancy is within a range that is significant for LDR sources.

  6. Deformable segmentation of 3D MR prostate images via distributed discriminative dictionary and ensemble learning

    International Nuclear Information System (INIS)

    Guo, Yanrong; Shao, Yeqin; Gao, Yaozong; Price, True; Oto, Aytekin; Shen, Dinggang

    2014-01-01

    Purpose: Automatic prostate segmentation from MR images is an important task in various clinical applications such as prostate cancer staging and MR-guided radiotherapy planning. However, the large appearance and shape variations of the prostate in MR images make the segmentation problem difficult to solve. Traditional Active Shape/Appearance Model (ASM/AAM) has limited accuracy on this problem, since its basic assumption, i.e., both shape and appearance of the targeted organ follow Gaussian distributions, is invalid in prostate MR images. To this end, the authors propose a sparse dictionary learning method to model the image appearance in a nonparametric fashion and further integrate the appearance model into a deformable segmentation framework for prostate MR segmentation. Methods: To drive the deformable model for prostate segmentation, the authors propose nonparametric appearance and shape models. The nonparametric appearance model is based on a novel dictionary learning method, namely distributed discriminative dictionary (DDD) learning, which is able to capture fine distinctions in image appearance. To increase the differential power of traditional dictionary-based classification methods, the authors' DDD learning approach takes three strategies. First, two dictionaries for prostate and nonprostate tissues are built, respectively, using the discriminative features obtained from minimum redundancy maximum relevance feature selection. Second, linear discriminant analysis is employed as a linear classifier to boost the optimal separation between prostate and nonprostate tissues, based on the representation residuals from sparse representation. Third, to enhance the robustness of the authors' classification method, multiple local dictionaries are learned for local regions along the prostate boundary (each with small appearance variations), instead of learning one global classifier for the entire prostate. These discriminative dictionaries are located on

  7. Deformable segmentation of 3D MR prostate images via distributed discriminative dictionary and ensemble learning

    Science.gov (United States)

    Guo, Yanrong; Gao, Yaozong; Shao, Yeqin; Price, True; Oto, Aytekin; Shen, Dinggang

    2014-01-01

    Purpose: Automatic prostate segmentation from MR images is an important task in various clinical applications such as prostate cancer staging and MR-guided radiotherapy planning. However, the large appearance and shape variations of the prostate in MR images make the segmentation problem difficult to solve. Traditional Active Shape/Appearance Model (ASM/AAM) has limited accuracy on this problem, since its basic assumption, i.e., both shape and appearance of the targeted organ follow Gaussian distributions, is invalid in prostate MR images. To this end, the authors propose a sparse dictionary learning method to model the image appearance in a nonparametric fashion and further integrate the appearance model into a deformable segmentation framework for prostate MR segmentation. Methods: To drive the deformable model for prostate segmentation, the authors propose nonparametric appearance and shape models. The nonparametric appearance model is based on a novel dictionary learning method, namely distributed discriminative dictionary (DDD) learning, which is able to capture fine distinctions in image appearance. To increase the differential power of traditional dictionary-based classification methods, the authors' DDD learning approach takes three strategies. First, two dictionaries for prostate and nonprostate tissues are built, respectively, using the discriminative features obtained from minimum redundancy maximum relevance feature selection. Second, linear discriminant analysis is employed as a linear classifier to boost the optimal separation between prostate and nonprostate tissues, based on the representation residuals from sparse representation. Third, to enhance the robustness of the authors' classification method, multiple local dictionaries are learned for local regions along the prostate boundary (each with small appearance variations), instead of learning one global classifier for the entire prostate. These discriminative dictionaries are located on different

  8. Deformable segmentation of 3D MR prostate images via distributed discriminative dictionary and ensemble learning.

    Science.gov (United States)

    Guo, Yanrong; Gao, Yaozong; Shao, Yeqin; Price, True; Oto, Aytekin; Shen, Dinggang

    2014-07-01

    Automatic prostate segmentation from MR images is an important task in various clinical applications such as prostate cancer staging and MR-guided radiotherapy planning. However, the large appearance and shape variations of the prostate in MR images make the segmentation problem difficult to solve. Traditional Active Shape/Appearance Model (ASM/AAM) has limited accuracy on this problem, since its basic assumption, i.e., both shape and appearance of the targeted organ follow Gaussian distributions, is invalid in prostate MR images. To this end, the authors propose a sparse dictionary learning method to model the image appearance in a nonparametric fashion and further integrate the appearance model into a deformable segmentation framework for prostate MR segmentation. To drive the deformable model for prostate segmentation, the authors propose nonparametric appearance and shape models. The nonparametric appearance model is based on a novel dictionary learning method, namely distributed discriminative dictionary (DDD) learning, which is able to capture fine distinctions in image appearance. To increase the differential power of traditional dictionary-based classification methods, the authors' DDD learning approach takes three strategies. First, two dictionaries for prostate and nonprostate tissues are built, respectively, using the discriminative features obtained from minimum redundancy maximum relevance feature selection. Second, linear discriminant analysis is employed as a linear classifier to boost the optimal separation between prostate and nonprostate tissues, based on the representation residuals from sparse representation. Third, to enhance the robustness of the authors' classification method, multiple local dictionaries are learned for local regions along the prostate boundary (each with small appearance variations), instead of learning one global classifier for the entire prostate. These discriminative dictionaries are located on different patches of the

  9. Deformable segmentation of 3D MR prostate images via distributed discriminative dictionary and ensemble learning

    Energy Technology Data Exchange (ETDEWEB)

    Guo, Yanrong; Shao, Yeqin [Department of Radiology and BRIC, University of North Carolina at Chapel Hill, North Carolina 27599 (United States); Gao, Yaozong; Price, True [Department of Radiology and BRIC, University of North Carolina at Chapel Hill, North Carolina 27599 and Department of Computer Science, University of North Carolina at Chapel Hill, North Carolina 27599 (United States); Oto, Aytekin [Department of Radiology, Section of Urology, University of Chicago, Illinois 60637 (United States); Shen, Dinggang, E-mail: dgshen@med.unc.edu [Department of Radiology and BRIC, University of North Carolina at Chapel Hill, North Carolina 27599 and Department of Brain and Cognitive Engineering, Korea University, Seoul 136-713 (Korea, Republic of)

    2014-07-15

    Purpose: Automatic prostate segmentation from MR images is an important task in various clinical applications such as prostate cancer staging and MR-guided radiotherapy planning. However, the large appearance and shape variations of the prostate in MR images make the segmentation problem difficult to solve. Traditional Active Shape/Appearance Model (ASM/AAM) has limited accuracy on this problem, since its basic assumption, i.e., both shape and appearance of the targeted organ follow Gaussian distributions, is invalid in prostate MR images. To this end, the authors propose a sparse dictionary learning method to model the image appearance in a nonparametric fashion and further integrate the appearance model into a deformable segmentation framework for prostate MR segmentation. Methods: To drive the deformable model for prostate segmentation, the authors propose nonparametric appearance and shape models. The nonparametric appearance model is based on a novel dictionary learning method, namely distributed discriminative dictionary (DDD) learning, which is able to capture fine distinctions in image appearance. To increase the differential power of traditional dictionary-based classification methods, the authors' DDD learning approach takes three strategies. First, two dictionaries for prostate and nonprostate tissues are built, respectively, using the discriminative features obtained from minimum redundancy maximum relevance feature selection. Second, linear discriminant analysis is employed as a linear classifier to boost the optimal separation between prostate and nonprostate tissues, based on the representation residuals from sparse representation. Third, to enhance the robustness of the authors' classification method, multiple local dictionaries are learned for local regions along the prostate boundary (each with small appearance variations), instead of learning one global classifier for the entire prostate. These discriminative dictionaries are located on

  10. Iterative Stable Alignment and Clustering of 2D Transmission Electron Microscope Images

    Science.gov (United States)

    Yang, Zhengfan; Fang, Jia; Chittuluru, Johnathan; Asturias, Francisco J.; Penczek, Pawel A.

    2012-01-01

    SUMMARY Identification of homogeneous subsets of images in a macromolecular electron microscopy (EM) image data set is a critical step in single-particle analysis. The task is handled by iterative algorithms, whose performance is compromised by the compounded limitations of image alignment and K-means clustering. Here we describe an approach, iterative stable alignment and clustering (ISAC) that, relying on a new clustering method and on the concepts of stability and reproducibility, can extract validated, homogeneous subsets of images. ISAC requires only a small number of simple parameters and, with minimal human intervention, can eliminate bias from two-dimensional image clustering and maximize the quality of group averages that can be used for ab initio three-dimensional structural determination and analysis of macromolecular conformational variability. Repeated testing of the stability and reproducibility of a solution within ISAC eliminates heterogeneous or incorrect classes and introduces critical validation to the process of EM image clustering. PMID:22325773

  11. Differentiation of prostatitis and prostate cancer by using diffusion-weighted MR imaging and MR-guided biopsy at 3 T

    NARCIS (Netherlands)

    Nagel, Klaas N.A.; Schouten, Martijn G.; Hambrock, Thomas; Litjens, Geert J.S.; Hoeks, Caroline; ten Haken, Bernard; Barentsz, Jelle O.; Fütterer, Johannes Jacobus; Fütterer, Jurgen J.

    2013-01-01

    Purpose To determine if prostatitis and prostate cancer (PCa) can be distinguished by using apparent diffusion coefficients (ADCs) on magnetic resonance (MR) images, with specimens obtained at MR-guided biopsy as the standard of reference. Materials and Methods The need for institutional review

  12. Differentiation of Prostatitis and Prostate Cancer by Using Diffusion-weighted MR Imaging and MR-guided Biopsy at 3 T

    NARCIS (Netherlands)

    Nagel, K.N.A.; Schouten, M.G.; Hambrock, T.; Litjens, G.J.S.; Hoeks, C.M.A.; Haken, B.T.; Barentsz, J.O.; Futterer, J.J.

    2013-01-01

    Purpose:To determine if prostatitis and prostate cancer (PCa) can be distinguished by using apparent diffusion coefficients (ADCs) on magnetic resonance (MR) images, with specimens obtained at MR-guided biopsy as the standard of reference.Materials and Methods:The need for institutional review board

  13. Note: A simple image processing based fiducial auto-alignment method for sample registration.

    Science.gov (United States)

    Robertson, Wesley D; Porto, Lucas R; Ip, Candice J X; Nantel, Megan K T; Tellkamp, Friedjof; Lu, Yinfei; Miller, R J Dwayne

    2015-08-01

    A simple method for the location and auto-alignment of sample fiducials for sample registration using widely available MATLAB/LabVIEW software is demonstrated. The method is robust, easily implemented, and applicable to a wide variety of experiment types for improved reproducibility and increased setup speed. The software uses image processing to locate and measure the diameter and center point of circular fiducials for distance self-calibration and iterative alignment and can be used with most imaging systems. The method is demonstrated to be fast and reliable in locating and aligning sample fiducials, provided here by a nanofabricated array, with accuracy within the optical resolution of the imaging system. The software was further demonstrated to register, load, and sample the dynamically wetted array.

  14. Simulation of high-resolution X-ray microscopic images for improved alignment

    International Nuclear Information System (INIS)

    Song Xiangxia; Zhang Xiaobo; Liu Gang; Cheng Xianchao; Li Wenjie; Guan Yong; Liu Ying; Xiong Ying; Tian Yangchao

    2011-01-01

    The introduction of precision optical elements to X-ray microscopes necessitates fine realignment to achieve optimal high-resolution imaging. In this paper, we demonstrate a numerical method for simulating image formation that facilitates alignment of the source, condenser, objective lens, and CCD camera. This algorithm, based on ray-tracing and Rayleigh-Sommerfeld diffraction theory, is applied to simulate the X-ray microscope beamline U7A of National Synchrotron Radiation Laboratory (NSRL). The simulations and imaging experiments show that the algorithm is useful for guiding experimental adjustments. Our alignment simulation method is an essential tool for the transmission X-ray microscope (TXM) with optical elements and may also be useful for the alignment of optical components in other modes of microscopy.

  15. Reliability of image-free navigation to monitor lower-limb alignment.

    Science.gov (United States)

    Pearle, Andrew D; Goleski, Patrick; Musahl, Volker; Kendoff, Daniel

    2009-02-01

    Proper alignment of the mechanical axis of the lower limb is the principal goal of a high tibial osteotomy. A well-accepted and relevant technical specification is the coronal plane lower-limb alignment. Target values for coronal plane alignment after high tibial osteotomy include 2 degrees of overcorrection, while tolerances for this specification have been established as 2 degrees to 4 degrees. However, the role of axial plane and sagittal plane realignment after high tibial osteotomy is poorly understood; consequently, targets and tolerance for this technical specification remain undefined. This article reviews the literature concerning the reliability and precision of navigation in monitoring the clinically relevant specification of lower-limb alignment in high tibial osteotomy. We conclude that image-free navigation registration may be clinically useful for intraoperative monitoring of the coronal plane only. Only fair and poor results for the axial and sagittal planes can be obtained by image-free navigation systems. In the future, combined image-based data, such as those from radiographs, magnetic resonance imaging, and gait analysis, may be used to help to improve the accuracy and reproducibility of quantitative intraoperative monitoring of lower-limb alignment.

  16. Giant prostatic utricle (utriculus masculinis): diagnostic imaging and surgical implications

    International Nuclear Information System (INIS)

    Lopatina, O.A.; Berry, T.T.; Spottswood, S.E.

    2004-01-01

    The prostatic utricle is an embryological remnant of the Mullerian duct system. It is often revealed incidentally on voiding cystourethrography in young males undergoing evaluation for possible vesicoureteral reflux. We present the case of a very large prostatic utricle found incidentally on ultrasound evaluation in a 4-year-old boy with a history of recurrent urinary tract infections. (orig.)

  17. Evaluation of magnetic resonance imaging-based prostate-specific antigen density of the prostate in the diagnosis of prostate cancer

    International Nuclear Information System (INIS)

    Hoshii, Tatsuhiko; Nishiyama, Tsutomu; Toyabe, Shinichi; Akazawa, Kohei; Komatsu, Shuichi; Kaneko, Masaaki; Hara, Noboru; Takahashi, Kota

    2007-01-01

    We evaluated prostate-specific antigen (PSA) density of the prostatic volume (PSAD) estimated using transrectal ultrasonography (TRUS; TRUS-based PSAD), magnetic resonance imaging (MRI; MRI-based PSAD), and PSA density of the transition zone (TZ) volume (PSATZD) estimated using MRI (MRI-based PSATZD) in the diagnosis of prostate cancer (PCa). One hundred and twenty patients, who were suspected to have PCa based on PSA, ranged between 4.1 and 20.0 ng/mL were enrolled in this study. The prostatic volume estimated using TRUS was smaller than the volume estimated using MRI by 11.4% in the patients with PSA levels ranging 4.1-20.0 ng/mL, 7.2% in those 4.1-10.0 ng/mL, and 15.7% in those 10.1-20.0 ng/mL, respectively. PSA levels were correlated with the prostatic volume estimated using TRUS and MRI, and TZ volume estimated using MRI in the patients without PCa; however, the level was not correlated with them in the patients with PCa. The area under the receiver operating characteristic curve of MRI-based PSAD was higher than that of TRUS-based PSAD; however, there was no statistical difference. Stepwise logistic regression analysis for the prediction of PCa by using PSA-related parameters confirmed that MRI-based PSATZD was the most significant predictor in patients with PSA levels in the range of 4.1-20.0 ng/mL (P<0.001), the range of 4.1-10.0 ng/mL (P=0.002), and the range of 10.1-20.0 ng/mL (P<0.001), respectively. The prostatic volume estimated using TRUS was smaller than the volume estimated using MRI. MRI-based PSATZD is the most significant predictor in the four parameters. (author)

  18. Prebiopsy magnetic resonance spectroscopy and imaging in the diagnosis of prostate cancer

    International Nuclear Information System (INIS)

    Kumar, V.; Jagannathan, N.R.; Thulkar, S.; Kumar, R.

    2012-01-01

    Existing screening investigations for the diagnosis of early prostate cancer lack specificity, resulting in a high negative biopsy rate. There is increasing interest in the use of various magnetic resonance methods for improving the yield of transrectal ultrasound-guided biopsies of the prostate in men suspected to have prostate cancer. We review the existing status of such investigations. A literature search was carried out using the Pubmed database to identify articles related to magnetic resonance methods for diagnosing prostate cancer. References from these articles were also extracted and reviewed. Recent studies have focused on prebiopsy magnetic resonance investigations using conventional magnetic resonance imaging, dynamic contrast enhanced magnetic resonance imaging, diffusion weighted magnetic resonance imaging, magnetization transfer imaging and magnetic resonance spectroscopy of the prostate. This marks a shift from the earlier strategy of carrying out postbiopsy magnetic resonance investigations. Prebiopsy magnetic resonance investigations has been useful in identifying patients who are more likely to have a biopsy positive for malignancy. Prebiopsy magnetic resonance investigations has a potential role in increasing specificity of screening for early prostate cancer. It has a role in the targeting of biopsy sites, avoiding unnecessary biopsies and predicting the outcome of biopsies. (author)

  19. Exploiting Interslice Correlation for MRI Prostate Image Segmentation, from Recursive Neural Networks Aspect

    Directory of Open Access Journals (Sweden)

    Qikui Zhu

    2018-01-01

    Full Text Available Segmentation of the prostate from Magnetic Resonance Imaging (MRI plays an important role in prostate cancer diagnosis. However, the lack of clear boundary and significant variation of prostate shapes and appearances make the automatic segmentation very challenging. In the past several years, approaches based on deep learning technology have made significant progress on prostate segmentation. However, those approaches mainly paid attention to features and contexts within each single slice of a 3D volume. As a result, this kind of approaches faces many difficulties when segmenting the base and apex of the prostate due to the limited slice boundary information. To tackle this problem, in this paper, we propose a deep neural network with bidirectional convolutional recurrent layers for MRI prostate image segmentation. In addition to utilizing the intraslice contexts and features, the proposed model also treats prostate slices as a data sequence and utilizes the interslice contexts to assist segmentation. The experimental results show that the proposed approach achieved significant segmentation improvement compared to other reported methods.

  20. The gastrin/cholecystokinin-B receptor on prostate cells--a novel target for bifunctional prostate cancer imaging.

    Science.gov (United States)

    Sturzu, Alexander; Klose, Uwe; Sheikh, Sumbla; Echner, Hartmut; Kalbacher, Hubert; Deeg, Martin; Nägele, Thomas; Schwentner, Christian; Ernemann, Ulrike; Heckl, Stefan

    2014-02-14

    The means of identifying prostate carcinoma and its metastases are limited. The contrast agents used in magnetic resonance imaging clinical diagnostics are not taken up into the tumor cells, but only accumulate in the interstitial space of the highly vasculated tumor. We examined the gastrin/cholecystokinin-B receptor as a possible target for prostate-specific detection using the C-terminal seven amino acid sequence of the gastrin peptide hormone. The correct sequence and a scrambled control sequence were coupled to the fluorescent dye rhodamine and the magnetic resonance imaging contrast agent gadolinium (Gd)-1,4,7,10-tetraazacyclododecane-1,4,7,10-tetraacetic acid (DOTA). Expression analysis of the gastrin receptor mRNA was performed by reverse transcriptase polymerase chain reaction on PC3 prostate carcinoma cells, U373 glioma, U2OS osteosarcoma and Colo205 colon carcinoma cells. After having confirmed elevated expression of gastrin receptor in PC3 cells and very low expression of the receptor in Colo205 cells, these two cell lines were used to create tumor xenografts on nude mice for in vivo experiments. Confocal lasers scanning microscopy and magnetic resonance imaging showed a high specificity of the correct conjugate for the PC3 xenografts. Staining of the PC3 xenografts was much weaker with the scrambled conjugate while the Colo205 xenografts showed no marked staining with any of the conjugates. In vitro experiments comparing the correct and scrambled conjugates on PC3 cells by magnetic resonance relaxometry and fluorescence-activated cell sorting confirmed markedly higher specificity of the correct conjugate. The investigations show that the gastrin receptor is a promising tumor cell surface target for future prostate-cancer-specific imaging applications. Copyright © 2013 Elsevier B.V. All rights reserved.

  1. An MR Contrast Agent for Intra-Prostatic Imaging of Prostatic Cancer

    National Research Council Canada - National Science Library

    Josephson, Lee

    2005-01-01

    An MR contrast agent targeted to the GRP receptor will be a novel pharmaceutical capable of non-invasively, and at high spatial resolution, characterizing healthy and patholological regions within the prostate...

  2. Limited evidence for the use of imaging to detect prostate cancer: A systematic review

    International Nuclear Information System (INIS)

    Blomqvist, L.; Carlsson, S.; Gjertsson, P.; Heintz, E.; Hultcrantz, M.; Mejare, I.; Andrén, O.

    2014-01-01

    Highlights: • In men with clinical suspicion of prostate cancer, ultrasound guided systematic biopsies is the golden standard for diagnosis. • Diagnostic imaging techniques, especially magnetic resonance imaging, is being used in trials to aid detection of prostate cancer. • To date, there is insufficient scientific evidence for the use of imaging techniques to detect prostate cancer. - Abstract: Objective: To assess the diagnostic accuracy of imaging technologies for detecting prostate cancer in patients with elevated PSA-values or suspected findings on clinical examination. Methods: The databases Medline, EMBASE, Cochrane, CRD HTA/DARE/NHS EED and EconLit were searched until June 2013. Pre-determined inclusion criteria were used to select full text articles. Risk of bias in individual studies was rated according to QUADAS or AMSTAR. Abstracts and full text articles were assessed independently by two reviewers. The performance of diagnostic imaging was compared with systematic biopsies (reference standard) and sensitivity and specificity were calculated. Results: The literature search yielded 5141 abstracts, which were reviewed by two independent reviewers. Of these 4852 were excluded since they did not meet the inclusion criteria. 288 articles were reviewed in full text for quality assessment. Six studies, three using MRI and three using transrectal ultrasound were included. All were rated as high risk of bias. Relevant studies on PET/CT were not identified. Conclusion: Despite clinical use, there is insufficient evidence regarding the accuracy of imaging technologies for detecting cancer in patients with suspected prostate cancer using TRUS guided systematic biopsies as reference standard

  3. Limited evidence for the use of imaging to detect prostate cancer: A systematic review

    Energy Technology Data Exchange (ETDEWEB)

    Blomqvist, L., E-mail: lennart.k.blomqvist@ki.se [Department of Diagnostic Radiology, Karolinska University Hospital, Solna (Sweden); Department of Molecular Medicine and Surgery, Karolinska Institutet, Stockholm (Sweden); Carlsson, S. [Department of Molecular Medicine and Surgery, Karolinska Institutet, Stockholm (Sweden); Department of Urology, Karolinska University Hospital, Solna (Sweden); Gjertsson, P. [Department of Clinical Physiology, Sahlgrenska University Hospital, Gothenburg (Sweden); Heintz, E.; Hultcrantz, M.; Mejare, I. [The Swedish Council on Health Technology Assessment, Stockholm (Sweden); Andrén, O. [School of Health and Medical Sciences, Örebro University, Örebro (Sweden); Department of Urology, Örebro University Hospital, Örebro (Sweden)

    2014-09-15

    Highlights: • In men with clinical suspicion of prostate cancer, ultrasound guided systematic biopsies is the golden standard for diagnosis. • Diagnostic imaging techniques, especially magnetic resonance imaging, is being used in trials to aid detection of prostate cancer. • To date, there is insufficient scientific evidence for the use of imaging techniques to detect prostate cancer. - Abstract: Objective: To assess the diagnostic accuracy of imaging technologies for detecting prostate cancer in patients with elevated PSA-values or suspected findings on clinical examination. Methods: The databases Medline, EMBASE, Cochrane, CRD HTA/DARE/NHS EED and EconLit were searched until June 2013. Pre-determined inclusion criteria were used to select full text articles. Risk of bias in individual studies was rated according to QUADAS or AMSTAR. Abstracts and full text articles were assessed independently by two reviewers. The performance of diagnostic imaging was compared with systematic biopsies (reference standard) and sensitivity and specificity were calculated. Results: The literature search yielded 5141 abstracts, which were reviewed by two independent reviewers. Of these 4852 were excluded since they did not meet the inclusion criteria. 288 articles were reviewed in full text for quality assessment. Six studies, three using MRI and three using transrectal ultrasound were included. All were rated as high risk of bias. Relevant studies on PET/CT were not identified. Conclusion: Despite clinical use, there is insufficient evidence regarding the accuracy of imaging technologies for detecting cancer in patients with suspected prostate cancer using TRUS guided systematic biopsies as reference standard.

  4. MR-CT registration using a Ni-Ti prostate stent in image-guided radiotherapy of prostate cancer.

    Science.gov (United States)

    Korsager, Anne Sofie; Carl, Jesper; Østergaard, Lasse Riis

    2013-06-01

    In image-guided radiotherapy of prostate cancer defining the clinical target volume often relies on magnetic resonance (MR). The task of transferring the clinical target volume from MR to standard planning computed tomography (CT) is not trivial due to prostate mobility. In this paper, an automatic local registration approach is proposed based on a newly developed removable Ni-Ti prostate stent. The registration uses the voxel similarity measure mutual information in a two-step approach where the pelvic bones are used to establish an initial registration for the local registration. In a phantom study, the accuracy was measured to 0.97 mm and visual inspection showed accurate registration of all 30 data sets. The consistency of the registration was examined where translation and rotation displacements yield a rotation error of 0.41° ± 0.45° and a translation error of 1.67 ± 2.24 mm. This study demonstrated the feasibility for an automatic local MR-CT registration using the prostate stent.

  5. MR-CT registration using a Ni-Ti prostate stent in image-guided radiotherapy of prostate cancer

    International Nuclear Information System (INIS)

    Korsager, Anne Sofie; Østergaard, Lasse Riis; Carl, Jesper

    2013-01-01

    Purpose: In image-guided radiotherapy of prostate cancer defining the clinical target volume often relies on magnetic resonance (MR). The task of transferring the clinical target volume from MR to standard planning computed tomography (CT) is not trivial due to prostate mobility. In this paper, an automatic local registration approach is proposed based on a newly developed removable Ni-Ti prostate stent.Methods: The registration uses the voxel similarity measure mutual information in a two-step approach where the pelvic bones are used to establish an initial registration for the local registration.Results: In a phantom study, the accuracy was measured to 0.97 mm and visual inspection showed accurate registration of all 30 data sets. The consistency of the registration was examined where translation and rotation displacements yield a rotation error of 0.41° ± 0.45° and a translation error of 1.67 ± 2.24 mm.Conclusions: This study demonstrated the feasibility for an automatic local MR-CT registration using the prostate stent.

  6. MR-CT registration using a Ni-Ti prostate stent in image-guided radiotherapy of prostate cancer

    Energy Technology Data Exchange (ETDEWEB)

    Korsager, Anne Sofie; Ostergaard, Lasse Riis [Department of Health Science and Technology, Aalborg University, Aalborg 9220 (Denmark); Carl, Jesper [Department of Medical Physics, Oncology, Aalborg Hospital, Aalborg 9100 (Denmark)

    2013-06-15

    Purpose: In image-guided radiotherapy of prostate cancer defining the clinical target volume often relies on magnetic resonance (MR). The task of transferring the clinical target volume from MR to standard planning computed tomography (CT) is not trivial due to prostate mobility. In this paper, an automatic local registration approach is proposed based on a newly developed removable Ni-Ti prostate stent.Methods: The registration uses the voxel similarity measure mutual information in a two-step approach where the pelvic bones are used to establish an initial registration for the local registration.Results: In a phantom study, the accuracy was measured to 0.97 mm and visual inspection showed accurate registration of all 30 data sets. The consistency of the registration was examined where translation and rotation displacements yield a rotation error of 0.41 Degree-Sign {+-} 0.45 Degree-Sign and a translation error of 1.67 {+-} 2.24 mm.Conclusions: This study demonstrated the feasibility for an automatic local MR-CT registration using the prostate stent.

  7. Prostate cancer detection by prebiopsy 3.0-tesla magnetic resonance imaging

    International Nuclear Information System (INIS)

    Nishida, Sachiyo; Kinoshita, Hidefumi; Mishima, Takao; Kurokawa, Hiroaki; Sakaida, Noriko; Matsuda, Tadashi

    2011-01-01

    The diagnostic value of 3.0-Tesla magnetic resonance imaging (MRI) for prostate cancer remains to be determined. The aim of the present study was to assess the features of prostate cancer detectable by prebiopsy 3.0-Tesla MRI. From January 2007 through to December 2008, 116 patients who were examined by prebiopsy 3.0-Tesla MRI underwent radical prostatectomy for localized prostate cancer. Prostate specimens were examined to see whether the largest cancer area was the same as the area indicated on the MRI. Univariate and multivariate logistic regression analyses were conducted to identify variables predictive of agreement between MRI and histopathological findings. Sixty-six (56.9%) patients were suspected of having prostate cancer on the basis of MRI findings. In 49 of these patients (74.2%), it was considered that there was agreement between the abnormal area on the MRI and the index tumor. Univariate analysis revealed that there were significant differences in abnormal digital rectal examination, capsular penetration, the diameter of the index tumor of the radical prostatectomy specimen, and the Gleason scores of the biopsy and radical prostatectomy specimens. Multivariate analysis revealed that the Gleason score of the radical prostatectomy specimen was associated with the accurate detection of the prostate cancer by MRI (P=0.0177). In conclusion, 3.0-Tesla MRI tends to accurately diagnose prostate cancer with high tumor burden and aggressiveness. Multimodal examination (T2-weighted imaging, dynamic contrast-enhanced imaging, and diffusion-weighted imaging) is recommended for the diagnosis of prostate cancer using 3.0-Tesla MRI. (author)

  8. Landmark matching based retinal image alignment by enforcing sparsity in correspondence matrix.

    Science.gov (United States)

    Zheng, Yuanjie; Daniel, Ebenezer; Hunter, Allan A; Xiao, Rui; Gao, Jianbin; Li, Hongsheng; Maguire, Maureen G; Brainard, David H; Gee, James C

    2014-08-01

    Retinal image alignment is fundamental to many applications in diagnosis of eye diseases. In this paper, we address the problem of landmark matching based retinal image alignment. We propose a novel landmark matching formulation by enforcing sparsity in the correspondence matrix and offer its solutions based on linear programming. The proposed formulation not only enables a joint estimation of the landmark correspondences and a predefined transformation model but also combines the benefits of the softassign strategy (Chui and Rangarajan, 2003) and the combinatorial optimization of linear programming. We also introduced a set of reinforced self-similarities descriptors which can better characterize local photometric and geometric properties of the retinal image. Theoretical analysis and experimental results with both fundus color images and angiogram images show the superior performances of our algorithms to several state-of-the-art techniques. Copyright © 2013 Elsevier B.V. All rights reserved.

  9. Image-based quantification of fiber alignment within electrospun tissue engineering scaffolds is related to mechanical anisotropy.

    Science.gov (United States)

    Fee, Timothy; Downs, Crawford; Eberhardt, Alan; Zhou, Yong; Berry, Joel

    2016-07-01

    It is well documented that electrospun tissue engineering scaffolds can be fabricated with variable degrees of fiber alignment to produce scaffolds with anisotropic mechanical properties. Several attempts have been made to quantify the degree of fiber alignment within an electrospun scaffold using image-based methods. However, these methods are limited by the inability to produce a quantitative measure of alignment that can be used to make comparisons across publications. Therefore, we have developed a new approach to quantifying the alignment present within a scaffold from scanning electron microscopic (SEM) images. The alignment is determined by using the Sobel approximation of the image gradient to determine the distribution of gradient angles with an image. This data was fit to a Von Mises distribution to find the dispersion parameter κ, which was used as a quantitative measure of fiber alignment. We fabricated four groups of electrospun polycaprolactone (PCL) + Gelatin scaffolds with alignments ranging from κ = 1.9 (aligned) to κ = 0.25 (random) and tested our alignment quantification method on these scaffolds. It was found that our alignment quantification method could distinguish between scaffolds of different alignments more accurately than two other published methods. Additionally, the alignment parameter κ was found to be a good predictor the mechanical anisotropy of our electrospun scaffolds. The ability to quantify fiber alignment within and make direct comparisons of scaffold fiber alignment across publications can reduce ambiguity between published results where cells are cultured on "highly aligned" fibrous scaffolds. This could have important implications for characterizing mechanics and cellular behavior on aligned tissue engineering scaffolds. © 2016 Wiley Periodicals, Inc. J Biomed Mater Res Part A: 104A: 1680-1686, 2016. © 2016 Wiley Periodicals, Inc.

  10. Intraocular lens alignment from purkinje and Scheimpflug imaging.

    Science.gov (United States)

    Rosales, Patricia; De Castro, Alberto; Jiménez-Alfaro, Ignacio; Marcos, Susana

    2010-11-01

    The improved designs of intraocular lenses (IOLs) implanted during cataract surgery demand understanding of the possible effects of lens misalignment on optical performance. In this review, we describe the implementation, set-up and validation of two methods to measure in vivo tilt and decentration of IOLs, one based on Purkinje imaging and the other on Scheimpflug imaging. The Purkinje system images the reflections of an oblique collimated light source on the anterior cornea and anterior and posterior IOL surfaces and relies on the well supported assumption of the linearity of the Purkinje images with respect to IOL tilt and decentration. Scheimpflug imaging requires geometrical distortion correction and image processing techniques to retrieve the pupillary axis, IOL axis and pupil centre from the three-dimensional anterior segment image of the eye. Validation of the techniques using a physical eye model indicates that IOL tilt is estimated within an accuracy of 0.261 degree and decentration within 0.161 mm. Measurements on patients implanted with aspheric IOLs indicate that IOL tilt and decentration tend to be mirror symmetric between left and right eyes. The average tilt was 1.54 degrees and the average decentration was 0.21 mm. Simulated aberration patterns using custom models of the patients eyes, built using anatomical data of the anterior cornea and foveal position, the IOL geometry and the measured IOL tilt and decentration predict the experimental wave aberrations measured using laser ray tracing aberrometry on the same eyes. This reveals a relatively minor contribution of IOL tilt and decentration on the higher-order aberrations of the normal pseudophakic eye.

  11. Stability Measurements for Alignment of the NIF Neutron Imaging System Pinhole Array

    International Nuclear Information System (INIS)

    Fittinghoff, D.N.; Bower, D.E.; Drury, O.B.; Dzenitis, J.M.; Frank, M.; Buckles, R.A.; Munson, C.; Wilde, C.H.

    2011-01-01

    The alignment system for the National Ignition Facility's neutron imaging system has been commissioned and measurements of the relative stability of the 90-315 DIM, the front and the back of the neutron imaging pinhole array and an exploding pusher target have been made using the 90-135 and the 90-258 opposite port alignment systems. Additionally, a laser beam shot from the neutron-imaging Annex and reflected from a mirror at the back of the pinhole array was used to monitor the pointing of the pinhole. Over a twelve hour period, the relative stability of these parts was found to be within ∼ ±18 (micro)m rms even when using manual methods for tracking the position of the objects. For highly visible features, use of basic particle tracking techniques found that the front of the pinhole array was stable relative to the 90-135 opposite port alignment camera to within ±3.4 (micro)m rms. Reregistration, however, of the opposite port alignment systems themselves using the target alignment sensor was found to change the expected position of target chamber center by up to 194 (micro)m.

  12. Metabolomic imaging of prostate cancer with magnetic resonance spectroscopy and mass spectrometry

    International Nuclear Information System (INIS)

    Spur, Eva-Margarete; Decelle, Emily A.; Cheng, Leo L.

    2013-01-01

    Metabolomic imaging of prostate cancer (PCa) aims to improve in vivo imaging capability so that PCa tumors can be localized noninvasively to guide biopsy and evaluated for aggressiveness prior to prostatectomy, as well as to assess and monitor PCa growth in patients with asymptomatic PCa newly diagnosed by biopsy. Metabolomics studies global variations of metabolites with which malignancy conditions can be evaluated by profiling the entire measurable metabolome, instead of focusing only on certain metabolites or isolated metabolic pathways. At present, PCa metabolomics is mainly studied by magnetic resonance spectroscopy (MRS) and mass spectrometry (MS). With MRS imaging, the anatomic image, obtained from magnetic resonance imaging, is mapped with values of disease condition-specific metabolomic profiles calculated from MRS of each location. For example, imaging of removed whole prostates has demonstrated the ability of metabolomic profiles to differentiate cancerous foci from histologically benign regions. Additionally, MS metabolomic imaging of prostate biopsies has uncovered metabolomic expression patterns that could discriminate between PCa and benign tissue. Metabolomic imaging offers the potential to identify cancer lesions to guide prostate biopsy and evaluate PCa aggressiveness noninvasively in vivo, or ex vivo to increase the power of pathology analysis. Potentially, this imaging ability could be applied not only to PCa, but also to different tissues and organs to evaluate other human malignancies and metabolic diseases. (orig.)

  13. Metabolomic imaging of prostate cancer with magnetic resonance spectroscopy and mass spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Spur, Eva-Margarete [Massachusetts General Hospital, Harvard Medical School, Department of Pathology, Boston, MA (United States); Massachusetts General Hospital, Harvard Medical School, Department of Radiology, Boston, MA (United States); Charite Universitaetsmedizin, Berlin (Germany); Decelle, Emily A.; Cheng, Leo L. [Massachusetts General Hospital, Harvard Medical School, Department of Pathology, Boston, MA (United States); Massachusetts General Hospital, Harvard Medical School, Department of Radiology, Boston, MA (United States)

    2013-07-15

    Metabolomic imaging of prostate cancer (PCa) aims to improve in vivo imaging capability so that PCa tumors can be localized noninvasively to guide biopsy and evaluated for aggressiveness prior to prostatectomy, as well as to assess and monitor PCa growth in patients with asymptomatic PCa newly diagnosed by biopsy. Metabolomics studies global variations of metabolites with which malignancy conditions can be evaluated by profiling the entire measurable metabolome, instead of focusing only on certain metabolites or isolated metabolic pathways. At present, PCa metabolomics is mainly studied by magnetic resonance spectroscopy (MRS) and mass spectrometry (MS). With MRS imaging, the anatomic image, obtained from magnetic resonance imaging, is mapped with values of disease condition-specific metabolomic profiles calculated from MRS of each location. For example, imaging of removed whole prostates has demonstrated the ability of metabolomic profiles to differentiate cancerous foci from histologically benign regions. Additionally, MS metabolomic imaging of prostate biopsies has uncovered metabolomic expression patterns that could discriminate between PCa and benign tissue. Metabolomic imaging offers the potential to identify cancer lesions to guide prostate biopsy and evaluate PCa aggressiveness noninvasively in vivo, or ex vivo to increase the power of pathology analysis. Potentially, this imaging ability could be applied not only to PCa, but also to different tissues and organs to evaluate other human malignancies and metabolic diseases. (orig.)

  14. Comparison of MR imaging and urodynamic findings in benign prostatic hyperplasia

    International Nuclear Information System (INIS)

    Alam, A.M.; Ishida, Jun; Igawa, Mikio; Sugimura, Kazuro; Okizuka, Hiromi

    2000-01-01

    In benign prostatic hyperplasia (BPH), it is uncertain whether the size of the prostate is related to the degree of urodynamically demonstrated bladder outlet obstruction. We compared MR imaging findings and urodynamic data in patients with surgically confirmed BPH. We prospectively studied 43 benign prostatic hyperplasia (BPH) patients in whom transurethral resection of the prostate (TURP) was planned. We obtained T1- and T2-weighted images in the transverse and sagittal planes with a 1.5 Tesla superconducting unit. The predicted volume of the inner gland and the peripheral zone were obtained on T2-weighted transverse images. Prostatic protrusion into the urinary bladder (IB protrusion) and the inner gland ratio (IG ratio: inner gland volume/total prostatic volume) were determined. IB protrusion and inner IG ratio were significantly greater in patients with severe stenosis than in those without. A surgical capsule (SC) was seen in 20 of 25 patients (80%) with severe stenosis and 8 of 18 (44%) of those without it. The accuracy of IB protrusion + IG ratio, IB protrusion + surgical capsule, and IB protrusion + IG ratio + surgical capsule was 89%, and that of IG ratio + surgical capsule was 86%. The inner gland ratio, protrusion into the bladder, and presence of surgical capsule were the most important factors in bladder outlet obstruction. The probability of outlet stenosis increases in patients with more than two of these criteria. (author)

  15. Comparison of MR imaging and urodynamic findings in benign prostatic hyperplasia

    Energy Technology Data Exchange (ETDEWEB)

    Alam, A.M.; Ishida, Jun; Igawa, Mikio [Shimane Medical Univ., Izumo (Japan); Sugimura, Kazuro; Okizuka, Hiromi

    2000-04-01

    In benign prostatic hyperplasia (BPH), it is uncertain whether the size of the prostate is related to the degree of urodynamically demonstrated bladder outlet obstruction. We compared MR imaging findings and urodynamic data in patients with surgically confirmed BPH. We prospectively studied 43 benign prostatic hyperplasia (BPH) patients in whom transurethral resection of the prostate (TURP) was planned. We obtained T1- and T2-weighted images in the transverse and sagittal planes with a 1.5 Tesla superconducting unit. The predicted volume of the inner gland and the peripheral zone were obtained on T2-weighted transverse images. Prostatic protrusion into the urinary bladder (IB protrusion) and the inner gland ratio (IG ratio: inner gland volume/total prostatic volume) were determined. IB protrusion and inner IG ratio were significantly greater in patients with severe stenosis than in those without. A surgical capsule (SC) was seen in 20 of 25 patients (80%) with severe stenosis and 8 of 18 (44%) of those without it. The accuracy of IB protrusion + IG ratio, IB protrusion + surgical capsule, and IB protrusion + IG ratio + surgical capsule was 89%, and that of IG ratio + surgical capsule was 86%. The inner gland ratio, protrusion into the bladder, and presence of surgical capsule were the most important factors in bladder outlet obstruction. The probability of outlet stenosis increases in patients with more than two of these criteria. (author)

  16. Interfraction Prostate Rotation Determined from In-Room Computerized Tomography Images

    International Nuclear Information System (INIS)

    Owen, Rebecca; Kron, Tomas; Foroudi, Farshad; Milner, Alvin; Cox, Jennifer; Duchesne, Gillian

    2011-01-01

    Fiducial markers (FMs) are commonly used as a correction technique for interfraction translations of the prostate. The aim of this investigation was to determine the magnitude of prostate rotations using 2 methods: FM coordinates and the anatomical border of the prostate and rectum. Daily computed tomography (CT) scans (n = 346) of 10 prostate cancer patients with 3 implanted FMs were acquired using the CT on rails. FM coordinates were used to determine rotation in the sagittal, transverse, and coronal planes, and CT contours of the prostate and rectum were used to determine rotation along the sagittal plane. An adaptive technique based on a subset of images (n = 6; planning and first 5 treatment CTs) to reduce systematic rotation errors in the sagittal plane was tested. The standard deviation (SD) of systematic rotation from FM coordinates was 7.6 o , 7.7 o , and 5.0 o in the sagittal, transverse and coronal planes. The corresponding SD of random error was 10.2 o , 15.8 o , and 6.5 o . Errors in the sagittal plane, determined from prostate and rectal contours, were 10.1 o (systematic) and 7.7 o (random). These results did not correlate with rotation computed from FM coordinates (r = -0.017; p = 0.753, n = 337). The systematic error could be reduced by 43% to 5.6 o when the mean prostate position was estimated from 6 CT scans. Prostate rotation is a significant source of error that appears to be more accurately determined using the anatomical border of the prostate and rectum rather than FMs, thus highlighting the utility of CT image guidance.

  17. Initial experience of 3 tesla endorectal coil magnetic resonance imaging and 1H-spectroscopic imaging of the prostate.

    NARCIS (Netherlands)

    Fütterer, J.J.; Scheenen, T.W.J.; Huisman, H.J.; Klomp, D.W.J.; Dorsten, F.A. van; Hulsbergen-van de Kaa, C.A.; Witjes, J.A.; Heerschap, A.; Barentsz, J.O.

    2004-01-01

    RATIONALE AND OBJECTIVES: We sought to explore the feasibility of magnetic resonance imaging (MRI) of the prostate at 3T, with the knowledge of potential drawbacks of MRI at high field strengths. MATERIAL AND METHOD: MRI, dynamic MRI, and 1H-MR spectroscopic imaging were performed in 10 patients

  18. Identification of threshold prostate specific antigen levels to optimize the detection of clinically significant prostate cancer by magnetic resonance imaging/ultrasound fusion guided biopsy.

    Science.gov (United States)

    Shakir, Nabeel A; George, Arvin K; Siddiqui, M Minhaj; Rothwax, Jason T; Rais-Bahrami, Soroush; Stamatakis, Lambros; Su, Daniel; Okoro, Chinonyerem; Raskolnikov, Dima; Walton-Diaz, Annerleim; Simon, Richard; Turkbey, Baris; Choyke, Peter L; Merino, Maria J; Wood, Bradford J; Pinto, Peter A

    2014-12-01

    Prostate specific antigen sensitivity increases with lower threshold values but with a corresponding decrease in specificity. Magnetic resonance imaging/ultrasound targeted biopsy detects prostate cancer more efficiently and of higher grade than standard 12-core transrectal ultrasound biopsy but the optimal population for its use is not well defined. We evaluated the performance of magnetic resonance imaging/ultrasound targeted biopsy vs 12-core biopsy across a prostate specific antigen continuum. We reviewed the records of all patients enrolled in a prospective trial who underwent 12-core transrectal ultrasound and magnetic resonance imaging/ultrasound targeted biopsies from August 2007 through February 2014. Patients were stratified by each of 4 prostate specific antigen cutoffs. The greatest Gleason score using either biopsy method was compared in and across groups as well as across the population prostate specific antigen range. Clinically significant prostate cancer was defined as Gleason 7 (4 + 3) or greater. Univariate and multivariate analyses were performed. A total of 1,003 targeted and 12-core transrectal ultrasound biopsies were performed, of which 564 diagnosed prostate cancer for a 56.2% detection rate. Targeted biopsy led to significantly more upgrading to clinically significant disease compared to 12-core biopsy. This trend increased more with increasing prostate specific antigen, specifically in patients with prostate specific antigen 4 to 10 and greater than 10 ng/ml. Prostate specific antigen 5.2 ng/ml or greater captured 90% of upgrading by targeted biopsy, corresponding to 64% of patients who underwent multiparametric magnetic resonance imaging and subsequent fusion biopsy. Conversely a greater proportion of clinically insignificant disease was detected by 12-core vs targeted biopsy overall. These differences persisted when controlling for potential confounders on multivariate analysis. Prostate cancer upgrading with targeted biopsy increases

  19. A prototype distributed object-oriented architecture for image-based automatic laser alignment

    International Nuclear Information System (INIS)

    Stout, E.A.; Kamm, V.J.M.; Spann, J.M.; Van Arsdall, P.J.

    1996-01-01

    Designing a computer control system for the National Ignition Facility (NIF) is a complex undertaking because of the system's large size and its distributed nature. The controls team is addressing that complexity by adopting the object-oriented programming paradigm, designing reusable software frameworks, and using the Common Object Request Broker Architecture (CORBA) for distribution. A prototype system for image-based automatic laser alignment has been developed to evaluate and gain experience with CORBA and OOP in a small distributed system. The prototype is also important in evaluating alignment concepts, image processing techniques, speed and accuracy of automatic alignment objectives for the NIF, and control hardware for aligment devices. The prototype system has met its inital objectives and provides a basis for continued development

  20. Fast prostate segmentation for brachytherapy based on joint fusion of images and labels

    Science.gov (United States)

    Nouranian, Saman; Ramezani, Mahdi; Mahdavi, S. Sara; Spadinger, Ingrid; Morris, William J.; Salcudean, Septimiu E.; Abolmaesumi, Purang

    2014-03-01

    Brachytherapy as one of the treatment methods for prostate cancer takes place by implantation of radioactive seeds inside the gland. The standard of care for this treatment procedure is to acquire transrectal ultrasound images of the prostate which are segmented in order to plan the appropriate seed placement. The segmentation process is usually performed either manually or semi-automatically and is associated with subjective errors because the prostate visibility is limited in ultrasound images. The current segmentation process also limits the possibility of intra-operative delineation of the prostate to perform real-time dosimetry. In this paper, we propose a computationally inexpensive and fully automatic segmentation approach that takes advantage of previously segmented images to form a joint space of images and their segmentations. We utilize joint Independent Component Analysis method to generate a model which is further employed to produce a probability map of the target segmentation. We evaluate this approach on the transrectal ultrasound volume images of 60 patients using a leave-one-out cross-validation approach. The results are compared with the manually segmented prostate contours that were used by clinicians to plan brachytherapy procedures. We show that the proposed approach is fast with comparable accuracy and precision to those found in previous studies on TRUS segmentation.

  1. Prostate Ultrasound

    Medline Plus

    Full Text Available ... pictures of a man’s prostate gland and to help diagnose symptoms such as difficulty urinating or an ... Ultrasound imaging is a noninvasive medical test that helps physicians diagnose and treat medical conditions. Prostate ultrasound, ...

  2. Prostate Ultrasound

    Medline Plus

    Full Text Available ... uses sound waves to produce pictures of a man’s prostate gland and to help diagnose symptoms such ... also called transrectal ultrasound, provides images of a man's prostate gland and surrounding tissue. The exam typically ...

  3. Prostate ultrasound imaging: evaluation of a two-step scoring system in the diagnosis of prostate cancer.

    Science.gov (United States)

    Gao, Yong; Liao, Xin-Hong; Ma, Yan; Lu, Lu; Wei, Li-Yan; Yan, Xue

    2017-12-01

    This study aims to investigate the feasibility and performance of a two-step scoring system of ultrasound imaging in the diagnosis of prostate cancer. 75 patients with 888 consecutive histopathologically verified lesions were included in this study. Step 1, an initial 5-point scoring system was developed based on conventional transrectal ultrasound (TRUS). Step 2, a final scoring system was evaluated according to contrast-enhanced transrectal ultrasound (CE-TRUS). Each lesion was evaluated using the two-step scoring system (step 1 + step 2) and compared with only using conventional TRUS (step 1). 888 lesions were histologically verified: 315 of them were prostate cancer from 46 patients and 573 were benign prostatic hypertrophy (BPH) from 29 patients. According to the two-step scoring system, 284 lesions were upgraded and 130 lesions were downgraded from step 1 to step 2 (this means using step 2 to assess the results by step 1). However, 96 cases were improperly upgraded after step 2 and 48 malignant lesions were still missed after step 2 as score-1. For the two-step scoring system, the sensitivity, specificity, and accuracy were 84.7%, 83.2%, and 83.7%, respectively, versus 22.8%, 96.6%, and 70.4%, respectively, for conventional TRUS. The area under the ROC curve (AUC) for lesion diagnosis was 0.799-0.952 for the two-step scoring system, versus 0.479-0.712 for conventional TRUS. The difference in the diagnostic accuracy of the two-step scoring system and conventional TRUS was statistically significant (Pstep scoring system was straightforward to use and achieved a considerably accurate diagnostic performance for prostate cancer. The application of the two-step scoring system for prostate cancer is promising.

  4. Biomechanical modeling constrained surface-based image registration for prostate MR guided TRUS biopsy

    NARCIS (Netherlands)

    Ven, W.J.M. van de; Hu, Y.; Barentsz, J.O.; Karssemeijer, N.; Barratt, D.; Huisman, H.J.

    2015-01-01

    Adding magnetic resonance (MR)-derived information to standard transrectal ultrasound (TRUS) images for guiding prostate biopsy is of substantial clinical interest. A tumor visible on MR images can be projected on ultrasound (US) by using MR-US registration. A common approach is to use surface-based

  5. Construction and application of hierarchical decision tree for classification of ultrasonographic prostate images

    NARCIS (Netherlands)

    Giesen, R. J.; Huynen, A. L.; Aarnink, R. G.; de la Rosette, J. J.; Debruyne, F. M.; Wijkstra, H.

    1996-01-01

    A non-parametric algorithm is described for the construction of a binary decision tree classifier. This tree is used to correlate textural features, computed from ultrasonographic prostate images, with the histopathology of the imaged tissue. The algorithm consists of two parts; growing and pruning.

  6. Advances in magnetic resonance imaging: how they are changing the management of prostate cancer

    NARCIS (Netherlands)

    Sciarra, A.; Barentsz, J.O.; Bjartell, A.; Eastham, J.; Hricak, H.; Panebianco, V.; Witjes, J.A.

    2011-01-01

    CONTEXT: Although magnetic resonance imaging (MRI) is emerging as the most commonly used imaging modality for prostate cancer (PCa) detection, treatment planning, and follow-up, its acceptance has not been uniform. Recently, great interest has been shown in multiparametric MRI, which combines

  7. Metabolic imaging of patients with prostate cancer using hyperpolarized [1-¹³C]pyruvate

    DEFF Research Database (Denmark)

    Nelson, Sarah J; Kurhanewicz, John; Vigneron, Daniel B

    2013-01-01

    This first-in-man imaging study evaluated the safety and feasibility of hyperpolarized [1-¹³C]pyruvate as an agent for noninvasively characterizing alterations in tumor metabolism for patients with prostate cancer. Imaging living systems with hyperpolarized agents can result in more than 10,000-f...

  8. Dual optimization based prostate zonal segmentation in 3D MR images.

    Science.gov (United States)

    Qiu, Wu; Yuan, Jing; Ukwatta, Eranga; Sun, Yue; Rajchl, Martin; Fenster, Aaron

    2014-05-01

    Efficient and accurate segmentation of the prostate and two of its clinically meaningful sub-regions: the central gland (CG) and peripheral zone (PZ), from 3D MR images, is of great interest in image-guided prostate interventions and diagnosis of prostate cancer. In this work, a novel multi-region segmentation approach is proposed to simultaneously segment the prostate and its two major sub-regions from only a single 3D T2-weighted (T2w) MR image, which makes use of the prior spatial region consistency and incorporates a customized prostate appearance model into the segmentation task. The formulated challenging combinatorial optimization problem is solved by means of convex relaxation, for which a novel spatially continuous max-flow model is introduced as the dual optimization formulation to the studied convex relaxed optimization problem with region consistency constraints. The proposed continuous max-flow model derives an efficient duality-based algorithm that enjoys numerical advantages and can be easily implemented on GPUs. The proposed approach was validated using 18 3D prostate T2w MR images with a body-coil and 25 images with an endo-rectal coil. Experimental results demonstrate that the proposed method is capable of efficiently and accurately extracting both the prostate zones: CG and PZ, and the whole prostate gland from the input 3D prostate MR images, with a mean Dice similarity coefficient (DSC) of 89.3±3.2% for the whole gland (WG), 82.2±3.0% for the CG, and 69.1±6.9% for the PZ in 3D body-coil MR images; 89.2±3.3% for the WG, 83.0±2.4% for the CG, and 70.0±6.5% for the PZ in 3D endo-rectal coil MR images. In addition, the experiments of intra- and inter-observer variability introduced by user initialization indicate a good reproducibility of the proposed approach in terms of volume difference (VD) and coefficient-of-variation (CV) of DSC. Copyright © 2014 Elsevier B.V. All rights reserved.

  9. SU-F-J-81: Evaluation of Automated Deformable Registration Between Planning Computed Tomography (CT) and Daily Cone Beam CT Images Over the Course of Prostate Cancer Radiotherapy

    Energy Technology Data Exchange (ETDEWEB)

    Matney, J; Hammers, J; Kaidar-Person, O; Wang, A; Chen, R; Das, S; Marks, L; Mavroidis, P [University North Carolina, Chapel Hill, NC (United States)

    2016-06-15

    Purpose: To compute daily dose delivered during radiotherapy, deformable registration needs to be relatively fast, automated, and accurate. The aim of this study was to evaluate the performance of commercial deformable registration software for deforming between two modalities: planning computed tomography (pCT) images acquired for treatment planning and cone beam (CB) CT images acquired prior to each fraction of prostate cancer radiotherapy. Methods: A workflow was designed using MIM Software™ that aligned and deformed pCT into daily CBCT images in two steps: (1) rigid shifts applied after daily CBCT imaging to align patient anatomy to the pCT and (2) normalized intensity-based deformable registration to account for interfractional anatomical variations. The physician-approved CTV and organ and risk (OAR) contours were deformed from the pCT to daily CBCT over the course of treatment. The same structures were delineated on each daily CBCT by a radiation oncologist. Dice similarity coefficient (DSC) mean and standard deviations were calculated to quantify the deformable registration quality for prostate, bladder, rectum and femoral heads. Results: To date, contour comparisons have been analyzed for 31 daily fractions of 2 of 10 of the cohort. Interim analysis shows that right and left femoral head contours demonstrate the highest agreement (DSC: 0.96±0.02) with physician contours. Additionally, deformed bladder (DSC: 0.81±0.09) and prostate (DSC: 0.80±0.07) have good agreement with physician-defined daily contours. Rectum contours have the highest variations (DSC: 0.66±0.10) between the deformed and physician-defined contours on daily CBCT imaging. Conclusion: For structures with relatively high contrast boundaries on CBCT, the MIM automated deformable registration provided accurate representations of the daily contours during treatment delivery. These findings will permit subsequent investigations to automate daily dose computation from CBCT. However

  10. T2-weighted endorectal magnetic resonance imaging of prostate cancer after external beam radiation therapy

    International Nuclear Information System (INIS)

    Westphalen, Antonio C.; Kurhanewicz, John; Cunha, Rui M.G.; Hsu, I-Chow; Kornak, John; Zhao, Shoujun; Coakley, Fergus V.

    2009-01-01

    Purpose: To retrospectively determine the accuracy of T2-weighted endorectal MR imaging in the detection of prostate cancer after external beam radiation therapy and to investigate the relationship between imaging accuracy and time since therapy. Materials and Methods: Institutional review board approval was obtained and the study was HIPPA compliant. We identified 59 patients who underwent 1.5 Tesla endorectal MR imaging of the prostate between 1999 and 2006 after definitive external beam radiation therapy for biopsy-proven prostate cancer. Two readers recorded the presence or absence of tumor on T2-weighted images. Logistic regression and Fisher's exact tests for 2x2 tables were used to determine the accuracy of imaging and investigate if accuracy differed between those imaged within 3 years of therapy (n = 25) and those imaged more than 3 years after therapy (n = 34). Transrectal biopsy was used as the standard of reference for the presence or absence of recurrent cancer. Results: Thirty-four of 59 patients (58%) had recurrent prostate cancer detected on biopsy. The overall accuracy of T2-weighted MR imaging in the detection cancer after external beam radiation therapy was 63% (37/59) for reader 1 and 71% for reader 2 (42/59). For both readers, logistic regression showed no difference in accuracy between those imaged within 3 years of therapy and those imaged more than 3 years after therapy (p = 0.86 for reader 1 and 0.44 for reader 2). Conclusion: T2-weighted endorectal MR imaging has low accuracy in the detection of prostate cancer after external beam radiation therapy, irrespective of the time since therapy. (author)

  11. Image-guided system versus manual marking for toric intraocular lens alignment in cataract surgery

    NARCIS (Netherlands)

    Webers, V.S.C.; Bauer, N.J.C.; Visser, N.; Berendschot, T.T.J.M.; van den Biggelaar, F.J.H.M.; Nuijts, R.M.M.A.

    2017-01-01

    Purpose To compare the accuracy of toric intraocular lens (IOL) alignment using the Verion Image-Guided System versus a conventional manual ink-marking procedure. Setting University Eye Clinic Maastricht, Maastricht, the Netherlands. Design Prospective randomized clinical trial. Methods Eyes with

  12. Detection and localization of carcinoma within the prostate using high resolution transrectal gamma imaging (TRGI) of monoclonal antibody directed at prostate specific membrane antigen (PSMA)—Proof of concept and initial imaging results

    International Nuclear Information System (INIS)

    Franc, Benjamin L.; Cho, Steve Y.; Rosenthal, Seth A.; Cui, Yonggang; Tsui, Benjamin; Vandewalker, Kristen M.N.; Holz, Andrew L.; Poonamallee, Uday; Pomper, Martin G.; James, Ralph B.

    2013-01-01

    Purpose: Molecular imaging methods may identify primary prostate cancer foci and potentially guide biopsy and optimal management approaches. In this exploratory study, safety and first human imaging experience of a novel solid state endocavity transrectal gamma-imaging (TRGI) device was evaluated. Methods: Twelve patients received 5 ± 0.5 mCi In-111 capromab pendetide (ProstaScint ® ) intravenously and the prostate of each was imaged 4 days later transrectally using an endoluminal cadmium zinc telluride (CZT)-based compact gamma camera (ProxiScan™, Hybridyne Imaging Technologies, Inc.). Immediate and 5–7-day post imaging safety assessments were performed. In those patients with a prostate cancer diagnosis (N = 10), single photon emission computed tomography (SPECT-CT) and magnetic resonance imaging (MRI) of the pelvis were also acquired. Images were reviewed and sites of suspected cancer were localized by prostate quadrant by consensus of two nuclear medicine physicians. Pathology from TRUS biopsy, or surgical pathology following prostatectomy (N = 3) when available, served as the gold standard. Results: There were no serious adverse events associated with TRGI. No focal signal was detected in patients without a diagnosis of prostate cancer (N = 2). Of 40 quadrants evaluated in the cancer cohort (N = 10), 22 contained malignancy. In 8 of these 10 patients, the most focal site of uptake on TRGI corresponded to a prostatic quadrant with biopsy-proven malignancy. In 6 cancer-containing quadrants, TRGI was positive where SPECT-CT was negative; MRI showed a detectable abnormality in only 1 of these 6 quadrants. Qualitative image review of the planar TRGI images for prostate cancer localization was severely limited in some cases by scatter artifact within the vicinity of the prostate gland arising from physiologic urine and blood pool activity from nearby structures. Conclusions: TRGI is a safe imaging method that can potentially detect radiopharmaceutical uptake

  13. Cryo-EM image alignment based on nonuniform fast Fourier transform.

    Science.gov (United States)

    Yang, Zhengfan; Penczek, Pawel A

    2008-08-01

    In single particle analysis, two-dimensional (2-D) alignment is a fundamental step intended to put into register various particle projections of biological macromolecules collected at the electron microscope. The efficiency and quality of three-dimensional (3-D) structure reconstruction largely depends on the computational speed and alignment accuracy of this crucial step. In order to improve the performance of alignment, we introduce a new method that takes advantage of the highly accurate interpolation scheme based on the gridding method, a version of the nonuniform fast Fourier transform, and utilizes a multi-dimensional optimization algorithm for the refinement of the orientation parameters. Using simulated data, we demonstrate that by using less than half of the sample points and taking twice the runtime, our new 2-D alignment method achieves dramatically better alignment accuracy than that based on quadratic interpolation. We also apply our method to image to volume registration, the key step in the single particle EM structure refinement protocol. We find that in this case the accuracy of the method not only surpasses the accuracy of the commonly used real-space implementation, but results are achieved in much shorter time, making gridding-based alignment a perfect candidate for efficient structure determination in single particle analysis.

  14. Cryo-EM image alignment based on nonuniform fast Fourier transform

    International Nuclear Information System (INIS)

    Yang Zhengfan; Penczek, Pawel A.

    2008-01-01

    In single particle analysis, two-dimensional (2-D) alignment is a fundamental step intended to put into register various particle projections of biological macromolecules collected at the electron microscope. The efficiency and quality of three-dimensional (3-D) structure reconstruction largely depends on the computational speed and alignment accuracy of this crucial step. In order to improve the performance of alignment, we introduce a new method that takes advantage of the highly accurate interpolation scheme based on the gridding method, a version of the nonuniform fast Fourier transform, and utilizes a multi-dimensional optimization algorithm for the refinement of the orientation parameters. Using simulated data, we demonstrate that by using less than half of the sample points and taking twice the runtime, our new 2-D alignment method achieves dramatically better alignment accuracy than that based on quadratic interpolation. We also apply our method to image to volume registration, the key step in the single particle EM structure refinement protocol. We find that in this case the accuracy of the method not only surpasses the accuracy of the commonly used real-space implementation, but results are achieved in much shorter time, making gridding-based alignment a perfect candidate for efficient structure determination in single particle analysis

  15. Online Image-based Monitoring of Soft-tissue Displacements for Radiation Therapy of the Prostate

    International Nuclear Information System (INIS)

    Schlosser, Jeffrey; Salisbury, Kenneth; Hristov, Dimitre

    2012-01-01

    Purpose: Emerging prolonged, hypofractionated radiotherapy regimens rely on high-dose conformality to minimize toxicity and thus can benefit from image guidance systems that continuously monitor target position during beam delivery. To address this need we previously developed, as a potential add-on device for existing linear accelerators, a novel telerobotic ultrasound system capable of real-time, soft-tissue imaging. Expanding on this capability, the aim of this work was to develop and characterize an image-based technique for real-time detection of prostate displacements. Methods and Materials: Image processing techniques were implemented on spatially localized ultrasound images to generate two parameters representing prostate displacements in real time. In a phantom and five volunteers, soft-tissue targets were continuously imaged with a customized robotic manipulator while recording the two tissue displacement parameters (TDPs). Variations of the TDPs in the absence of tissue displacements were evaluated, as was the sensitivity of the TDPs to prostate translations and rotations. Robustness of the approach to probe force was also investigated. Results: With 95% confidence, the proposed method detected in vivo prostate displacements before they exceeded 2.3, 2.5, and 2.8 mm in anteroposterior, superoinferior, and mediolateral directions. Prostate pitch was detected before exceeding 4.7° at 95% confidence. Total system time lag averaged 173 ms, mostly limited by ultrasound acquisition rate. False positives (FPs) (FP) in the absence of displacements did not exceed 1.5 FP events per 10 min of continuous in vivo imaging time. Conclusions: The feasibility of using telerobotic ultrasound for real-time, soft-tissue–based monitoring of target displacements was confirmed in vivo. Such monitoring has the potential to detect small clinically relevant intrafractional variations of the prostate position during beam delivery.

  16. A novel 111In-labeled anti-PSMA nanobody for targeted SPECT/CT imaging of prostate cancer

    NARCIS (Netherlands)

    Chatalic, K.L.S.; Veldhoven-Zweistra, J.; Bolkestein, M.; Hoeben, S.; Koning, G.A.; Boerman, O.C.; Jong, M. de; Weerden, W.M. van

    2015-01-01

    Prostate-specific Membrane Antigen (PSMA) is overexpressed in prostate cancer (PCa) and a promising target for molecular imaging and therapy. Nanobodies (single domain antibodies, VHH) are the smallest antibody-based fragments possessing ideal molecular imaging properties, such as high target

  17. Magnetic resonance imaging for the detection, localisation, and characterisation of prostate cancer: recommendations from a European consensus meeting

    NARCIS (Netherlands)

    Dickinson, L.; Ahmed, H.U.; Allen, C.; Barentsz, J.O.; Carey, B.; Futterer, J.J.; Heijmink, S.W.T.P.J.; Hoskin, P.J.; Kirkham, A.; Padhani, A.R.; Persad, R.; Puech, P.; Punwani, S.; Sohaib, A.S.; Tombal, B.; Villers, A.; Meulen, J. van der; Emberton, M.

    2011-01-01

    BACKGROUND: Multiparametric magnetic resonance imaging (mpMRI) may have a role in detecting clinically significant prostate cancer in men with raised serum prostate-specific antigen levels. Variations in technique and the interpretation of images have contributed to inconsistency in its reported

  18. Synergistic Instance-Level Subspace Alignment for Fine-Grained Sketch-Based Image Retrieval.

    Science.gov (United States)

    Li, Ke; Pang, Kaiyue; Song, Yi-Zhe; Hospedales, Timothy M; Xiang, Tao; Zhang, Honggang

    2017-08-25

    We study the problem of fine-grained sketch-based image retrieval. By performing instance-level (rather than category-level) retrieval, it embodies a timely and practical application, particularly with the ubiquitous availability of touchscreens. Three factors contribute to the challenging nature of the problem: (i) free-hand sketches are inherently abstract and iconic, making visual comparisons with photos difficult, (ii) sketches and photos are in two different visual domains, i.e. black and white lines vs. color pixels, and (iii) fine-grained distinctions are especially challenging when executed across domain and abstraction-level. To address these challenges, we propose to bridge the image-sketch gap both at the high-level via parts and attributes, as well as at the low-level, via introducing a new domain alignment method. More specifically, (i) we contribute a dataset with 304 photos and 912 sketches, where each sketch and image is annotated with its semantic parts and associated part-level attributes. With the help of this dataset, we investigate (ii) how strongly-supervised deformable part-based models can be learned that subsequently enable automatic detection of part-level attributes, and provide pose-aligned sketch-image comparisons. To reduce the sketch-image gap when comparing low-level features, we also (iii) propose a novel method for instance-level domain-alignment, that exploits both subspace and instance-level cues to better align the domains. Finally (iv) these are combined in a matching framework integrating aligned low-level features, mid-level geometric structure and high-level semantic attributes. Extensive experiments conducted on our new dataset demonstrate effectiveness of the proposed method.

  19. Everyman's prostate phantom: kiwi-fruit substitute for human prostates at magnetic resonance imaging, diffusion-weighted imaging and magnetic resonance spectroscopy

    Energy Technology Data Exchange (ETDEWEB)

    Mueller-Lisse, Ullrich G.; Murer, Sophie; Kuhn, Marissa [University of Munich (' ' Ludwig-Maximilians-Universitaet' ' , LMU), Department of Radiology, Faculty of Medicine, Muenchen (Germany); Mueller-Lisse, Ulrike L. [University of Munich (' ' Ludwig-Maximilians-Universitaet' ' , LMU), Department of Urology, Faculty of Medicine, Muenchen (Germany); Interdisciplinary Oncology Centre Munich (IOZ), Department of Urology, Munich (Germany); Scheidler, Juergen [University of Munich (' ' Ludwig-Maximilians-Universitaet' ' , LMU), Department of Radiology, Faculty of Medicine, Muenchen (Germany); Radiology Centre Munich (RZM), Muenchen (Germany); Scherr, Michael [University of Munich (' ' Ludwig-Maximilians-Universitaet' ' , LMU), Department of Radiology, Faculty of Medicine, Muenchen (Germany); BG Unfallklinik Murnau, Department of Radiology, Murnau am Staffelsee (Germany)

    2017-08-15

    To apply an easy-to-assemble phantom substitute for human prostates in T2-weighted magnetic resonance imaging (T2WI), diffusion-weighted imaging (DWI) and 3D magnetic resonance spectroscopy (MRS). Kiwi fruit were fixed with gel hot and cold compress packs on two plastic nursery pots, separated by a plastic plate, and submerged in tap water inside a 1-L open-spout plastic watering can for T2WI (TR/TE 7500/101 ms), DWI (5500/61 ms, ADC b50-800 s/mm{sup 2} map) and MRS (940/145 ms) at 3.0 T, with phased array surface coils. One green kiwi fruit was additionally examined with an endorectal coil. Retrospective comparison with benign peripheral zone (PZ) and transitional zone (TZ) of prostate (n = 5), Gleason 6-7a prostate cancer (n = 8) and Gleason 7b-9 prostate cancer (n = 7) validated the phantom. Mean contrast between central placenta (CP) and outer pericarp (OP, 0.346-0.349) or peripheral placenta (PP, 0.364-0.393) of kiwi fruit was similar to Gleason 7b-9 prostate cancer and PZ (0.308) in T2WI. ADC values of OP and PP (1.27 ± 0.07-1.37 ± 0.08 mm{sup 2}/s x 10{sup -3}) resembled PZ and TZ (1.39 ± 0.17-1.60 ± 0.24 mm{sup 2}/s x 10{sup -3}), while CP (0.91 ± 0.14-0.99 ± 0.10 mm{sup 2}/s x 10{sup -3}) resembled Gleason 7b-9 prostate cancer (1.00 ± 0.25 mm{sup 2}/s x 10{sup -3}). MR spectra showed peaks of citrate and myo-inositol in kiwi fruit, and citrate and ''choline+creatine'' in prostates. The phantom worked with an endorectal coil, too. The kiwi fruit phantom reproducibly showed zones similar to PZ, TZ and cancer in human prostates in T2WI and DWI and two metabolite peaks in MRS and appears suitable to compare different MR protocols, coil systems and scanners. (orig.)

  20. Vertically aligned carbon nanotube emitter on metal foil for medical X-ray imaging.

    Science.gov (United States)

    Ryu, Je Hwang; Kim, Wan Sun; Lee, Seung Ho; Eom, Young Ju; Park, Hun Kuk; Park, Kyu Chang

    2013-10-01

    A simple method is proposed for growing vertically aligned carbon nanotubes on metal foil using the triode direct current plasma-enhanced chemical vapor deposition (PECVD). The carbon nanotube (CNT) electron emitter was fabricated using fewer process steps with an acid treated metal substrate. The CNT emitter was used for X-ray generation, and the X-ray image of mouse's joint was obtained with an anode current of 0.5 mA at an anode bias of 60 kV. The simple fabrication of a well-aligned CNT with a protection layer on metal foil, and its X-ray application, were studied.

  1. Alignment of the Measurement Scale Mark during Immersion Hydrometer Calibration Using an Image Processing System

    Directory of Open Access Journals (Sweden)

    Jose Emilio Vargas-Soto

    2013-10-01

    Full Text Available The present work presents an improved method to align the measurement scale mark in an immersion hydrometer calibration system of CENAM, the National Metrology Institute (NMI of Mexico, The proposed method uses a vision system to align the scale mark of the hydrometer to the surface of the liquid where it is immersed by implementing image processing algorithms. This approach reduces the variability in the apparent mass determination during the hydrostatic weighing in the calibration process, therefore decreasing the relative uncertainty of calibration.

  2. Alignment of the Measurement Scale Mark during Immersion Hydrometer Calibration Using an Image Processing System

    Science.gov (United States)

    Peña-Perez, Luis Manuel; Pedraza-Ortega, Jesus Carlos; Ramos-Arreguin, Juan Manuel; Arriaga, Saul Tovar; Fernandez, Marco Antonio Aceves; Becerra, Luis Omar; Hurtado, Efren Gorrostieta; Vargas-Soto, Jose Emilio

    2013-01-01

    The present work presents an improved method to align the measurement scale mark in an immersion hydrometer calibration system of CENAM, the National Metrology Institute (NMI) of Mexico, The proposed method uses a vision system to align the scale mark of the hydrometer to the surface of the liquid where it is immersed by implementing image processing algorithms. This approach reduces the variability in the apparent mass determination during the hydrostatic weighing in the calibration process, therefore decreasing the relative uncertainty of calibration. PMID:24284770

  3. SU-E-J-24: Image-Guidance Using Cone-Beam CT for Stereotactic Body Radiotherapy (SBRT) of Lung Cancer Patients: Bony Alignment or Soft Tissue Alignment?

    Science.gov (United States)

    Wang, L; Turaka, A; Meyer, J; Spoka, D; Jin, L; Fan, J; Ma, C

    2012-06-01

    To assess the reliability of soft tissue alignment by comparing pre- and post-treatment cone-beam CT (CBCT) for image guidance in stereotactic body radiotherapy (SBRT) of lung cancers. Our lung SBRT procedures require all patients undergo 4D CT scan in order to obtain patient-specific target motion information through reconstructed 4D data using the maximum-intensity projection (MIP) algorithm. The internal target volume (ITV) was outlined directly from the MIP images and a 3-5 mm margin expansion was then applied to the ITV to create the PTV. Conformal treatment planning was performed on the helical images, to which the MIP images were fused. Prior to each treatment, CBCT was used for image guidance by comparing with the simulation CT and for patient relocalization based on the bony anatomy. Any displacement of the patient bony structure would be considered as setup errors and would be corrected by couch shifts. Theoretically, as the PTV definition included target internal motion, no further shifts other than setup corrections should be made. However, it is our practice to have treating physicians further check target localization within the PTV. Whenever the shifts based on the soft-tissue alignment (that is, target alignment) exceeded a certain value (e.g. 5 mm), a post-treatment CBCT was carried out to ensure that the tissue alignment is reliable by comparing between pre- and post-treatment CBCT. Pre- and post-CBCT has been performed for 7 patients so far who had shifts beyond 5 mm despite bony alignment. For all patients, post CBCT confirmed that the visualized target position was kept in the same position as before treatment after adjusting for soft-tissue alignment. For the patient population studied, it is shown that soft-tissue alignment is necessary and reliable in the lung SBRT for individual cases. © 2012 American Association of Physicists in Medicine.

  4. Magnetic resonance imaging and morphometric histologic analysis of prostate tissue composition in predicting the clinical outcome of terazosin therapy in benign prostatic hyperplasia

    Energy Technology Data Exchange (ETDEWEB)

    Isen, K. [Karaelmas Univ., Zonguldak (Turkey). School of Medicine; Sinik, Z.; Alkibay, T.; Sezer, C.; Soezen, S.; Atilla, S.; Ataoglu, O.; Isik, S.

    2001-02-01

    The purpose of this study was to determine whether magnetic resonance imaging (MRI) or quantitative color-imaged morphometric analysis (MA) of the prostate gland are related to the clinical response to terazosin. Thirty-six male patients with symptomatic benign prostatic hyperplasia (BPH) with a serum prostate-specific antigen level of 4-10 ng/mL underwent MRI with body coil, transrectal prostate unltrasonography and biopsy prior to terazosin therapy. For MRI-determined stromal and non-stromal BPH, the ratio of the signal intensity of the inner gland to the obturator internus muscle was evaluated. Histologic sections were stained with hematoxylin and eosin. The MA of the specimens was performed by Samba 2000. Results of the two techniques were interpreted according to the terazosin therapy results. The mean stromal percentage was 60.5{+-}18.0%. No statistically significant relationship was found between the clinical outcome of terazosin and the MRI findings. The MA results showed a significant relationship between the percentage of stroma and the percent change of the peak urinary flow rate, but not with the percent change of the international prostate symptom score after terazosin therapy (P<0.05). Magnetic resonance imaging alone is not sufficient in predicting the response to terazosin therapy. Morphometric analysis of BPH tissue composition can be used in predicting the clinical outcome of terazosin therapy but it is suitable only in patients for whom prostatic biopsy is necessary in order to rule out prostate cancer. (author)

  5. Magnetic resonance imaging and morphometric histologic analysis of prostate tissue composition in predicting the clinical outcome of terazosin therapy in benign prostatic hyperplasia

    International Nuclear Information System (INIS)

    Isen, K.; Sinik, Z.; Alkibay, T.; Sezer, C.; Soezen, S.; Atilla, S.; Ataoglu, O.; Isik, S.

    2001-01-01

    The purpose of this study was to determine whether magnetic resonance imaging (MRI) or quantitative color-imaged morphometric analysis (MA) of the prostate gland are related to the clinical response to terazosin. Thirty-six male patients with symptomatic benign prostatic hyperplasia (BPH) with a serum prostate-specific antigen level of 4-10 ng/mL underwent MRI with body coil, transrectal prostate unltrasonography and biopsy prior to terazosin therapy. For MRI-determined stromal and non-stromal BPH, the ratio of the signal intensity of the inner gland to the obturator internus muscle was evaluated. Histologic sections were stained with hematoxylin and eosin. The MA of the specimens was performed by Samba 2000. Results of the two techniques were interpreted according to the terazosin therapy results. The mean stromal percentage was 60.5±18.0%. No statistically significant relationship was found between the clinical outcome of terazosin and the MRI findings. The MA results showed a significant relationship between the percentage of stroma and the percent change of the peak urinary flow rate, but not with the percent change of the international prostate symptom score after terazosin therapy (P<0.05). Magnetic resonance imaging alone is not sufficient in predicting the response to terazosin therapy. Morphometric analysis of BPH tissue composition can be used in predicting the clinical outcome of terazosin therapy but it is suitable only in patients for whom prostatic biopsy is necessary in order to rule out prostate cancer. (author)

  6. Binocular contrast-gain control for natural scenes: Image structure and phase alignment.

    Science.gov (United States)

    Huang, Pi-Chun; Dai, Yu-Ming

    2018-05-01

    In the context of natural scenes, we applied the pattern-masking paradigm to investigate how image structure and phase alignment affect contrast-gain control in binocular vision. We measured the discrimination thresholds of bandpass-filtered natural-scene images (targets) under various types of pedestals. Our first experiment had four pedestal types: bandpass-filtered pedestals, unfiltered pedestals, notch-filtered pedestals (which enabled removal of the spatial frequency), and misaligned pedestals (which involved rotation of unfiltered pedestals). Our second experiment featured six types of pedestals: bandpass-filtered, unfiltered, and notch-filtered pedestals, and the corresponding phase-scrambled pedestals. The thresholds were compared for monocular, binocular, and dichoptic viewing configurations. The bandpass-filtered pedestal and unfiltered pedestals showed classic dipper shapes; the dipper shapes of the notch-filtered, misaligned, and phase-scrambled pedestals were weak. We adopted a two-stage binocular contrast-gain control model to describe our results. We deduced that the phase-alignment information influenced the contrast-gain control mechanism before the binocular summation stage and that the phase-alignment information and structural misalignment information caused relatively strong divisive inhibition in the monocular and interocular suppression stages. When the pedestals were phase-scrambled, the elimination of the interocular suppression processing was the most convincing explanation of the results. Thus, our results indicated that both phase-alignment information and similar image structures cause strong interocular suppression. Copyright © 2018 Elsevier Ltd. All rights reserved.

  7. Imaging of Prostate Cancer Using Urokinase-Type Plasminogen Activator Receptor PET

    DEFF Research Database (Denmark)

    Skovgaard, Dorthe; Persson, Morten; Kjaer, Andreas

    2017-01-01

    Urokinase-type plasminogen activator receptor (uPAR) overexpression is an important biomarker for aggressiveness in cancer including prostate cancer (PC) and provides independent clinical information in addition to prostate-specific antigen and Gleason score. This article focuses on uPAR PET...... as a new diagnostic and prognostic imaging biomarker in PC. Many preclinical uPAR-targeted PET imaging studies using AE105 in cancer models have been undertaken with promising results. A major breakthrough was obtained with the recent human translation of uPAR PET in using 64Cu- and 68Ga-labelled versions...

  8. Integration of Architectural and Cytologic Driven Image Algorithms for Prostate Adenocarcinoma Identification

    Directory of Open Access Journals (Sweden)

    Jason Hipp

    2012-01-01

    Full Text Available Introduction: The advent of digital slides offers new opportunities within the practice of pathology such as the use of image analysis techniques to facilitate computer aided diagnosis (CAD solutions. Use of CAD holds promise to enable new levels of decision support and allow for additional layers of quality assurance and consistency in rendered diagnoses. However, the development and testing of prostate cancer CAD solutions requires a ground truth map of the cancer to enable the generation of receiver operator characteristic (ROC curves. This requires a pathologist to annotate, or paint, each of the malignant glands in prostate cancer with an image editor software - a time consuming and exhaustive process.

  9. Automated detection of a prostate Ni-Ti stent in electronic portal images.

    Science.gov (United States)

    Carl, Jesper; Nielsen, Henning; Nielsen, Jane; Lund, Bente; Larsen, Erik Hoejkjaer

    2006-12-01

    Planning target volumes (PTV) in fractionated radiotherapy still have to be outlined with wide margins to the clinical target volume due to uncertainties arising from daily shift of the prostate position. A recently proposed new method of visualization of the prostate is based on insertion of a thermo-expandable Ni-Ti stent. The current study proposes a new detection algorithm for automated detection of the Ni-Ti stent in electronic portal images. The algorithm is based on the Ni-Ti stent having a cylindrical shape with a fixed diameter, which was used as the basis for an automated detection algorithm. The automated method uses enhancement of lines combined with a grayscale morphology operation that looks for enhanced pixels separated with a distance similar to the diameter of the stent. The images in this study are all from prostate cancer patients treated with radiotherapy in a previous study. Images of a stent inserted in a humanoid phantom demonstrated a localization accuracy of 0.4-0.7 mm which equals the pixel size in the image. The automated detection of the stent was compared to manual detection in 71 pairs of orthogonal images taken in nine patients. The algorithm was successful in 67 of 71 pairs of images. The method is fast, has a high success rate, good accuracy, and has a potential for unsupervised localization of the prostate before radiotherapy, which would enable automated repositioning before treatment and allow for the use of very tight PTV margins.

  10. Automated detection of a prostate Ni-Ti stent in electronic portal images

    International Nuclear Information System (INIS)

    Carl, Jesper; Nielsen, Henning; Nielsen, Jane; Lund, Bente; Larsen, Erik Hoejkjaer

    2006-01-01

    Planning target volumes (PTV) in fractionated radiotherapy still have to be outlined with wide margins to the clinical target volume due to uncertainties arising from daily shift of the prostate position. A recently proposed new method of visualization of the prostate is based on insertion of a thermo-expandable Ni-Ti stent. The current study proposes a new detection algorithm for automated detection of the Ni-Ti stent in electronic portal images. The algorithm is based on the Ni-Ti stent having a cylindrical shape with a fixed diameter, which was used as the basis for an automated detection algorithm. The automated method uses enhancement of lines combined with a grayscale morphology operation that looks for enhanced pixels separated with a distance similar to the diameter of the stent. The images in this study are all from prostate cancer patients treated with radiotherapy in a previous study. Images of a stent inserted in a humanoid phantom demonstrated a localization accuracy of 0.4-0.7 mm which equals the pixel size in the image. The automated detection of the stent was compared to manual detection in 71 pairs of orthogonal images taken in nine patients. The algorithm was successful in 67 of 71 pairs of images. The method is fast, has a high success rate, good accuracy, and has a potential for unsupervised localization of the prostate before radiotherapy, which would enable automated repositioning before treatment and allow for the use of very tight PTV margins

  11. 11C-Choline PET/pathology image coregistration in primary localized prostate cancer

    International Nuclear Information System (INIS)

    Grosu, Anca-Ligia; Prokic, Vesna; Weirich, Gregor; Wendl, Christina; Geinitz, Hans; Molls, Michael; Kirste, Simon; Souvatzoglou, Michael; Schwaiger, Markus; Gschwend, Juergen E.; Treiber, Uwe; Weber, Wolfgang A.; Krause, Bernd Joachim

    2014-01-01

    The aim of this study was to develop a methodology for the comparison of pathology specimens after prostatectomy (post-S) with PET images obtained before surgery (pre-S). This method was used to evaluate the merit of 11 C-choline PET/CT for delineation of gross tumour volume (GTV) in prostate cancer (PC). In 28 PC patients, 11 C-choline PET/CT was performed before surgery. PET/CT data were coregistered with the pathology specimens. GTV on PET images (GTV-PET) was outlined automatically and corrected manually. Tumour volume in the prostate (TVP) was delineated manually on the pathology specimens. Based on the coregistered PET/pathology images, the following parameters were assessed: SUVmax and SUVmean in the tumoral and nontumoral prostate (NP), GTV-PET (millilitres) and TVP (millilitres). PET/pathology image coregistration was satisfactory. Mean SUVmax in the TVP was lower than in the NP: 5.0 and 5.5, respectively (p = 0.093). Considering the entire prostate, SUVmax was located in the TVP in two patients, in the TVP and NP in 12 patients and exclusively in NP in 14 patients. Partial overlap the TVP and GTV-PET was seen in 71 % of patients, and complete overlap in 4 %. PET/pathology image coregistration can be used for evaluation of different imaging modalities. 11 C-Choline PET failed to distinguish tumour from nontumour tissue. (orig.)

  12. Implementation of large area CMOS image sensor module using the precision align inspection

    International Nuclear Information System (INIS)

    Kim, Byoung Wook; Kim, Toung Ju; Ryu, Cheol Woo; Lee, Kyung Yong; Kim, Jin Soo; Kim, Myung Soo; Cho, Gyu Seong

    2014-01-01

    This paper describes a large area CMOS image sensor module Implementation using the precision align inspection program. This work is needed because wafer cutting system does not always have high precision. The program check more than 8 point of sensor edges and align sensors with moving table. The size of a 2×1 butted CMOS image sensor module which except for the size of PCB is 170 mm×170 mm. And the pixel size is 55 μm×55 μm and the number of pixels is 3,072×3,072. The gap between the two CMOS image sensor module was arranged in less than one pixel size

  13. Group sparse multiview patch alignment framework with view consistency for image classification.

    Science.gov (United States)

    Gui, Jie; Tao, Dacheng; Sun, Zhenan; Luo, Yong; You, Xinge; Tang, Yuan Yan

    2014-07-01

    No single feature can satisfactorily characterize the semantic concepts of an image. Multiview learning aims to unify different kinds of features to produce a consensual and efficient representation. This paper redefines part optimization in the patch alignment framework (PAF) and develops a group sparse multiview patch alignment framework (GSM-PAF). The new part optimization considers not only the complementary properties of different views, but also view consistency. In particular, view consistency models the correlations between all possible combinations of any two kinds of view. In contrast to conventional dimensionality reduction algorithms that perform feature extraction and feature selection independently, GSM-PAF enjoys joint feature extraction and feature selection by exploiting l(2,1)-norm on the projection matrix to achieve row sparsity, which leads to the simultaneous selection of relevant features and learning transformation, and thus makes the algorithm more discriminative. Experiments on two real-world image data sets demonstrate the effectiveness of GSM-PAF for image classification.

  14. Implementation of large area CMOS image sensor module using the precision align inspection

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Byoung Wook; Kim, Toung Ju; Ryu, Cheol Woo [Radiation Imaging Technology Center, JBTP, Iksan (Korea, Republic of); Lee, Kyung Yong; Kim, Jin Soo [Nano Sol-Tech INC., Iksan (Korea, Republic of); Kim, Myung Soo; Cho, Gyu Seong [Dept. of Nuclear and Quantum Engineering, KAIST, Daejeon (Korea, Republic of)

    2014-12-15

    This paper describes a large area CMOS image sensor module Implementation using the precision align inspection program. This work is needed because wafer cutting system does not always have high precision. The program check more than 8 point of sensor edges and align sensors with moving table. The size of a 2×1 butted CMOS image sensor module which except for the size of PCB is 170 mm×170 mm. And the pixel size is 55 μm×55 μm and the number of pixels is 3,072×3,072. The gap between the two CMOS image sensor module was arranged in less than one pixel size.

  15. Evaluation of alignment error due to a speed artifact in stereotactic ultrasound image guidance

    International Nuclear Information System (INIS)

    Salter, Bill J; Wang, Brian; Szegedi, Martin W; Rassiah-Szegedi, Prema; Shrieve, Dennis C; Cheng, Roger; Fuss, Martin

    2008-01-01

    Ultrasound (US) image guidance systems used in radiotherapy are typically calibrated for soft tissue applications, thus introducing errors in depth-from-transducer representation when used in media with a different speed of sound propagation (e.g. fat). This error is commonly referred to as the speed artifact. In this study we utilized a standard US phantom to demonstrate the existence of the speed artifact when using a commercial US image guidance system to image through layers of simulated body fat, and we compared the results with calculated/predicted values. A general purpose US phantom (speed of sound (SOS) = 1540 m s -1 ) was imaged on a multi-slice CT scanner at a 0.625 mm slice thickness and 0.5 mm x 0.5 mm axial pixel size. Target-simulating wires inside the phantom were contoured and later transferred to the US guidance system. Layers of various thickness (1-8 cm) of commercially manufactured fat-simulating material (SOS = 1435 m s -1 ) were placed on top of the phantom to study the depth-related alignment error. In order to demonstrate that the speed artifact is not caused by adding additional layers on top of the phantom, we repeated these measurements in an identical setup using commercially manufactured tissue-simulating material (SOS = 1540 m s -1 ) for the top layers. For the fat-simulating material used in this study, we observed the magnitude of the depth-related alignment errors resulting from the speed artifact to be 0.7 mm cm -1 of fat imaged through. The measured alignment errors caused by the speed artifact agreed with the calculated values within one standard deviation for all of the different thicknesses of fat-simulating material studied here. We demonstrated the depth-related alignment error due to the speed artifact when using US image guidance for radiation treatment alignment and note that the presence of fat causes the target to be aliased to a depth greater than it actually is. For typical US guidance systems in use today, this will

  16. Evaluation of alignment error due to a speed artifact in stereotactic ultrasound image guidance.

    Science.gov (United States)

    Salter, Bill J; Wang, Brian; Szegedi, Martin W; Rassiah-Szegedi, Prema; Shrieve, Dennis C; Cheng, Roger; Fuss, Martin

    2008-12-07

    Ultrasound (US) image guidance systems used in radiotherapy are typically calibrated for soft tissue applications, thus introducing errors in depth-from-transducer representation when used in media with a different speed of sound propagation (e.g. fat). This error is commonly referred to as the speed artifact. In this study we utilized a standard US phantom to demonstrate the existence of the speed artifact when using a commercial US image guidance system to image through layers of simulated body fat, and we compared the results with calculated/predicted values. A general purpose US phantom (speed of sound (SOS) = 1540 m s(-1)) was imaged on a multi-slice CT scanner at a 0.625 mm slice thickness and 0.5 mm x 0.5 mm axial pixel size. Target-simulating wires inside the phantom were contoured and later transferred to the US guidance system. Layers of various thickness (1-8 cm) of commercially manufactured fat-simulating material (SOS = 1435 m s(-1)) were placed on top of the phantom to study the depth-related alignment error. In order to demonstrate that the speed artifact is not caused by adding additional layers on top of the phantom, we repeated these measurements in an identical setup using commercially manufactured tissue-simulating material (SOS = 1540 m s(-1)) for the top layers. For the fat-simulating material used in this study, we observed the magnitude of the depth-related alignment errors resulting from the speed artifact to be 0.7 mm cm(-1) of fat imaged through. The measured alignment errors caused by the speed artifact agreed with the calculated values within one standard deviation for all of the different thicknesses of fat-simulating material studied here. We demonstrated the depth-related alignment error due to the speed artifact when using US image guidance for radiation treatment alignment and note that the presence of fat causes the target to be aliased to a depth greater than it actually is. For typical US guidance systems in use today, this will

  17. Multi-atlas-based automatic 3D segmentation for prostate brachytherapy in transrectal ultrasound images

    Science.gov (United States)

    Nouranian, Saman; Mahdavi, S. Sara; Spadinger, Ingrid; Morris, William J.; Salcudean, S. E.; Abolmaesumi, P.

    2013-03-01

    One of the commonly used treatment methods for early-stage prostate cancer is brachytherapy. The standard of care for planning this procedure is segmentation of contours from transrectal ultrasound (TRUS) images, which closely follow the prostate boundary. This process is currently performed either manually or using semi-automatic techniques. This paper introduces a fully automatic segmentation algorithm which uses a priori knowledge of contours in a reference data set of TRUS volumes. A non-parametric deformable registration method is employed to transform the atlas prostate contours to a target image coordinates. All atlas images are sorted based on their registration results and the highest ranked registration results are selected for decision fusion. A Simultaneous Truth and Performance Level Estimation algorithm is utilized to fuse labels from registered atlases and produce a segmented target volume. In this experiment, 50 patient TRUS volumes are obtained and a leave-one-out study on TRUS volumes is reported. We also compare our results with a state-of-the-art semi-automatic prostate segmentation method that has been clinically used for planning prostate brachytherapy procedures and we show comparable accuracy and precision within clinically acceptable runtime.

  18. MR imaging of prostatic neoplasms with and without Gd-DTPA as intravenous contrast agent

    International Nuclear Information System (INIS)

    Schmidt, H.; Beer, M.; Schnabl, G.; Hahn, D.; Naegele, M.

    1986-01-01

    Nine patients with prostatic carcinoma (proved by radical prostatectomy in five and by TUR in four), five patients with benign prostatic hyperplasia (BPH, proved by adenomectomy in two and by TUR in three) and three control subjects underwent MR imaging performed using the Siemens Magnetom (1.0T) and the spin echo sequences 1.6/30,90,0.5/30, and 0.2/20 msec prior to, and the sequences 0.5/30 and 0.2/20 after, administration of Gd-DTPA (0.2 mmol/kg). The normal prostate showed a low, homogeneous signal enhancement. In BPH, the signal enhancement of the adenoma varied widely. In three of the five patients the adenoma was better demarcated from the pseudocapsule after administration of Gd-DTPA than on the precontrast image. The prostatic carcinoma showed only slightly less signal enhancement than BPH. On the postcontrast image, six of the nine carcinomas were visualized as a hyperintense nodule. However, reliable differentiation of prostatic carcinoma from BPH by means of signal enhancement was not possible

  19. The Role of Seminal Vesicle Motion in Target Margin Assessment for Online Image-Guided Radiotherapy for Prostate Cancer

    International Nuclear Information System (INIS)

    Liang Jian; Wu Qiuwen; Yan Di

    2009-01-01

    Purpose: For patients with intermediate- and high-risk prostate cancer, the seminal vesicles (SVs) are included in the clinical target volume (CTV). The purposes of this study are to investigate interfraction motion characteristics of the SVs and determine proper margins for online computed tomography image guidance. Methods and Materials: Twenty-four patients, each with 16 daily helical computed tomography scans, were included in this study. A binary image mask was used for image registration to determine daily organ motion. Two online image-guided radiotherapy strategies (prostate only and prostate + SVs) were simulated in a hypofractionated scheme. Three margin designs were studied for both three-dimensional conformal radiotherapy and intensity-modulated radiotherapy (IMRT). In prostate-only guidance, Margin A was uniformly applied to the whole CTV, and Margin B was applied to the SVs with a fixed 3-mm prostate margin. In prostate plus SV guidance, Margin C was uniformly applied to the CTV. The minimum margins were sought to satisfy the criterion that minimum cumulative CTV dose be more than those of the planning target volume in the plan for greater than 95% of patients. Results: The prostate and SVs move significantly more in the anterior-posterior and superior-inferior than right-left directions. The anterior-posterior motion of the prostate and SVs correlated (R 2 = 0.7). The SVs move significantly more than the prostate. The minimum margins found were 2.5 mm for three-dimensional conformal radiotherapy and 4.5, 4.5, and 3.0 mm for Margins A, B, and C for IMRT, respectively. Margins for IMRT were larger, but the irradiated volume and doses to critical structures were smaller. Minimum margins of 4.5 mm to the SVs and 3 mm to the prostate are recommended for IMRT with prostate-only guidance. Conclusions: The SVs move independently from the prostate gland, and additional margins are necessary for image-guided radiotherapy

  20. Imaging response during therapy with radium-223 for castration-resistant prostate cancer with bone metastases

    DEFF Research Database (Denmark)

    Keizman, D; Fosboel, M O; Reichegger, H

    2017-01-01

    BACKGROUND: The imaging response to radium-223 therapy is at present poorly described. We aimed to describe the imaging response to radium-223 treatment. METHODS: We retrospectively evaluated the computed tomography (CT) and bone scintigraphy response of metastatic castration-resistant prostate c....../or radiological) may be noted during the first 3 months, and should not be confused with progression. Imaging by CT scan should be considered after three and six doses of radium-223 to rule out extraskeletal disease progression....

  1. Differentiation among prostate cancer patients with Gleason score of 7 using histopathology whole-slide image and genomic data

    Science.gov (United States)

    Ren, Jian; Karagoz, Kubra; Gatza, Michael; Foran, David J.; Qi, Xin

    2018-03-01

    Prostate cancer is the most common non-skin related cancer affecting 1 in 7 men in the United States. Treatment of patients with prostate cancer still remains a difficult decision-making process that requires physicians to balance clinical benefits, life expectancy, comorbidities, and treatment-related side effects. Gleason score (a sum of the primary and secondary Gleason patterns) solely based on morphological prostate glandular architecture has shown as one of the best predictors of prostate cancer outcome. Significant progress has been made on molecular subtyping prostate cancer delineated through the increasing use of gene sequencing. Prostate cancer patients with Gleason score of 7 show heterogeneity in recurrence and survival outcomes. Therefore, we propose to assess the correlation between histopathology images and genomic data with disease recurrence in prostate tumors with a Gleason 7 score to identify prognostic markers. In the study, we identify image biomarkers within tissue WSIs by modeling the spatial relationship from automatically created patches as a sequence within WSI by adopting a recurrence network model, namely long short-term memory (LSTM). Our preliminary results demonstrate that integrating image biomarkers from CNN with LSTM and genomic pathway scores, is more strongly correlated with patients recurrence of disease compared to standard clinical markers and engineered image texture features. The study further demonstrates that prostate cancer patients with Gleason score of 4+3 have a higher risk of disease progression and recurrence compared to prostate cancer patients with Gleason score of 3+4.

  2. Nuclear Imaging for Assessment of Prostate Cancer Gene Therapy

    Science.gov (United States)

    2007-03-01

    thymidine kinase transfected EL4 cells . Further exploration of Tc-99m conjugated potential HSV1-TK substrates is still undergoing in our laboratory...prostate cancer cells , has been demonstrated the utility for tissue-specific toxic gene therapy for prostate cancer[10, 11]. Therefore, an adenovirus...BJ5183 together with pAdeasy-1, the viral DNA plasmid. The pAdeasy-1 is E1 and E3 deleted, its E1 function can be complemented in 293A cells . The

  3. Relationship between nanotopographical alignment and stem cell fate with live imaging and shape analysis

    Science.gov (United States)

    Newman, Peter; Galenano-Niño, Jorge Luis; Graney, Pamela; Razal, Joselito M.; Minett, Andrew I.; Ribas, João; Ovalle-Robles, Raquel; Biro, Maté; Zreiqat, Hala

    2016-12-01

    The topography of a biomaterial regulates cellular interactions and determine stem cell fate. A complete understanding of how topographical properties affect cell behavior will allow the rational design of material surfaces that elicit specified biological functions once placed in the body. To this end, we fabricate substrates with aligned or randomly organized fibrous nanostructured topographies. Culturing adipose-derived stem cells (ASCs), we explore the dynamic relationship between the alignment of topography, cell shape and cell differentiation to osteogenic and myogenic lineages. We show aligned topographies differentiate cells towards a satellite cell muscle progenitor state - a distinct cell myogenic lineage responsible for postnatal growth and repair of muscle. We analyze cell shape between the different topographies, using fluorescent time-lapse imaging over 21 days. In contrast to previous work, this allows the direct measurement of cell shape at a given time rather than defining the morphology of the underlying topography and neglecting cell shape. We report quantitative metrics of the time-based morphological behaviors of cell shape in response to differing topographies. This analysis offers insights into the relationship between topography, cell shape and cell differentiation. Cells differentiating towards a myogenic fate on aligned topographies adopt a characteristic elongated shape as well as the alignment of cells.

  4. Calibration results using highly aberrated images for aligning the JWST instruments to the telescope

    Science.gov (United States)

    Smith, Koby Z.; Acton, D. Scott; Gallagher, Ben B.; Knight, J. Scott; Dean, Bruce H.; Jurling, Alden S.; Zielinski, Thomas P.

    2016-07-01

    The James Webb Space Telescope (JWST) project is an international collaboration led by NASA's Goddard Space Flight Center (GSFC) in Greenbelt, MD. JWST is NASA's flagship observatory that will operate nearly a million miles away from Earth at the L2 Lagrange point. JWST's optical design is a three-mirror anastigmat with four main optical components; 1) the eighteen Primary Mirror Segment Assemblies (PMSA), 2) a single Secondary Mirror Assembly (SMA), 3) an Aft-Optics Subsystem (AOS) consisting of a Tertiary Mirror and Fine Steering Mirror, and 4) an Integrated Science Instrument Module consisting of the various instruments for JWST. JWST's optical system has been designed to accommodate a significant amount of alignment capability and risk with the PMSAs and SMA having rigid body motion available on-orbit just for alignment purposes. However, the Aft-Optics Subsystem (AOS) and Integrated Science Instrument Module (ISIM) are essentially fixed optical subsystems within JWST, and therefore the cryogenic alignment of the AOS to the ISIM is critical to the optical performance and mission success of JWST. In support of this cryogenic alignment of the AOS to ISIM, an array of fiber optic sources, known as the AOS Source Plate Assembly (ASPA), are placed near the intermediate image location of JWST (between the secondary and tertiary mirrors) during thermal vacuum ground-test operations. The AOS produces images of the ASPA fiber optic sources at the JWST focal surface location, where they are captured by the various science instruments. In this manner, the AOS provides an optical yardstick by which the instruments within ISIM can evaluate their relative positions to and the alignment of the AOS to ISIM can be quantified. However, since the ASPA is located at the intermediate image location of the JWST three-mirror anastigmat design, the images of these fiber optic sources produced by the AOS are highly aberrated with approximately 2-3μm RMS wavefront error consisting

  5. Multiparametric magnetic resonance imaging characteristics of normal, benign and malignant conditions in the prostate

    Energy Technology Data Exchange (ETDEWEB)

    Visschere, Pieter J.L. de; Pattyn, Eva; Villeirs, Geert M. [Ghent University Hospital, Department of Radiology, Ghent (Belgium); Vral, Anne [Ghent University Hospital, Department of Basic Medical Sciences, Ghent (Belgium); Perletti, Gianpaolo [Ghent University Hospital, Department of Basic Medical Sciences, Ghent (Belgium); University of Insubria, Clinical Pharmacology, Medical and Surgical Sciences Section, Department of Biotechnology and Life Sciences, Varese (Italy); Praet, Marleen [Ghent University Hospital, Department of Pathology, Ghent (Belgium); Magri, Vittorio [Instituti Clinici di Perfezionamento, Urology Clinic, Milano (Italy)

    2017-05-15

    To identify the multiparametric magnetic resonance imaging (mpMRI) characteristics of normal, benign and malignant conditions in the prostate. Fifty-six histopathological whole-mount radical prostatectomy specimens from ten randomly selected patients with prostate cancer (PC) were matched with corresponding transverse mpMRI slices. The mpMRI was performed prior to biopsy and consisted of T2-weighted imaging (T2-WI), diffusion-weighted imaging (DWI), dynamic contrast-enhanced imaging (DCE) and magnetic resonance spectroscopic imaging (MRSI). In each prostate specimen, a wide range of histopathological conditions were observed. They showed consistent but overlapping characteristics on mpMRI. Normal glands in the transition zone showed lower signal intensity (SI) on T2-WI, lower ADC values and lower citrate peaks on MRSI as compared to the peripheral zone (PZ) due to sparser glandular elements and more prominent collagenous fibres. In the PZ, normal glands were iso-intense on T2-WI, while high SI areas represented cystic atrophy. Mimickers of well-differentiated PC on mpMRI were inflammation, adenosis, HG-PIN and post-atrophic hyperplasia. Each prostate is a unique mix of normal, benign and/or malignant areas that vary in extent and distribution resulting in very heterogeneous characteristics on mpMRI. Understanding the main concepts of this mpMRI-histopathological correlation may increase the diagnostic confidence in reporting mpMRI. (orig.)

  6. The progress in diagnostic imaging for staging of bladder and prostate cancer. Endorectal magnetic resonance imaging and magnetization transfer contrast

    International Nuclear Information System (INIS)

    Arima, Kiminobu; Hayashi, Norio; Yanagawa, Makoto; Kawamura, Juichi; Kobayashi, Shigeki; Takeda, Kan; Sugimura, Yoshiki

    1999-01-01

    We retrospectively studied the staging accuracy of endorectal magnetic resonance imaging (MRI) in comparison with transrectal ultrasound examination (TRUS) for 71 localized bladder cancers and 19 localized prostate cancers (PC) radically resected. The accuracy of clinical staging for bladder cancer in endorectal MRI and TRUS was 85.9% and 69.2%, respectively. The presence or absence of the continuity of submucosal enhancement on T2-weighted MRI images could be useful for the staging of bladder cancer. The accuracy of the seminal vesicular invasion for prostate cancer in endorectal MRI and TRUS was 95% and 63%, respectively. To determine whether magnetization transfer contrast (MTC) provides additional information in the diagnosis of prostate cancer, the magnetization transfer ratios (MTRs) were calculated in 22 patients with PC, 5 with benign prostatic hyperplasia (BPH) and 4 controls. The mean MTR in the peripheral zone of the normal prostate (8.0%±3.4 [standard deviation]) showed a statistically significant decrease relative to that in the inner zone of the normal prostate (27.4%±3.4, p<0.01), BPH (25.5%±3.7, p<0.01), pre-treatment PC (30.6%±5.9, p<0.01), and PC after hormonal therapy (20.3%±6.3, p<0.01). The mean MTR in pre-treatment PC was significantly higher than that in BPH, or in PC after hormonal therapy (p<0.01). MTC was considered to be useful for conspicuity of prostate cancer lesion. (author)

  7. Compact CdZnTe-Based Gamma Camera For Prostate Cancer Imaging

    International Nuclear Information System (INIS)

    Cui, Y.; Lall, T.; Tsui, B.; Yu, J.; Mahler, G.; Bolotnikov, A.; Vaska, P.; DeGeronimo, G.; O'Connor, P.; Meinken, G.; Joyal, J.; Barrett, J.; Camarda, G.; Hossain, A.; Kim, K.H.; Yang, G.; Pomper, M.; Cho, S.; Weisman, K.; Seo, Y.; Babich, J.; LaFrance, N.; James, R.B.

    2011-01-01

    In this paper, we discuss the design of a compact gamma camera for high-resolution prostate cancer imaging using Cadmium Zinc Telluride (CdZnTe or CZT) radiation detectors. Prostate cancer is a common disease in men. Nowadays, a blood test measuring the level of prostate specific antigen (PSA) is widely used for screening for the disease in males over 50, followed by (ultrasound) imaging-guided biopsy. However, PSA tests have a high false-positive rate and ultrasound-guided biopsy has a high likelihood of missing small cancerous tissues. Commercial methods of nuclear medical imaging, e.g. PET and SPECT, can functionally image the organs, and potentially find cancer tissues at early stages, but their applications in diagnosing prostate cancer has been limited by the smallness of the prostate gland and the long working distance between the organ and the detectors comprising these imaging systems. CZT is a semiconductor material with wide band-gap and relatively high electron mobility, and thus can operate at room temperature without additional cooling. CZT detectors are photon-electron direct-conversion devices, thus offering high energy-resolution in detecting gamma rays, enabling energy-resolved imaging, and reducing the background of Compton-scattering events. In addition, CZT material has high stopping power for gamma rays; for medical imaging, a few-mm-thick CZT material provides adequate detection efficiency for many SPECT radiotracers. Because of these advantages, CZT detectors are becoming popular for several SPECT medical-imaging applications. Most recently, we designed a compact gamma camera using CZT detectors coupled to an application-specific-integrated-circuit (ASIC). This camera functions as a trans-rectal probe to image the prostate gland from a distance of only 1-5 cm, thus offering higher detection efficiency and higher spatial resolution. Hence, it potentially can detect prostate cancers at their early stages. The performance tests of this camera

  8. Joint Processing of Envelope Alignment and Phase Compensation for Isar Imaging

    Science.gov (United States)

    Chen, Tao; Jin, Guanghu; Dong, Zhen

    2018-04-01

    Range envelope alignment and phase compensation are spilt into two isolated parts in the classical methods of translational motion compensation in Inverse Synthetic Aperture Radar (ISAR) imaging. In classic method of the rotating object imaging, the two reference points of the envelope alignment and the Phase Difference (PD) estimation are probably not the same point, making it difficult to uncouple the coupling term by conducting the correction of Migration Through Resolution Cell (MTRC). In this paper, an improved approach of joint processing which chooses certain scattering point as the sole reference point is proposed to perform with utilizing the Prominent Point Processing (PPP) method. With this end in view, we firstly get the initial image using classical methods from which a certain scattering point can be chose. The envelope alignment and phase compensation using the selected scattering point as the same reference point are subsequently conducted. The keystone transform is thus smoothly applied to further improve imaging quality. Both simulation experiments and real data processing are provided to demonstrate the performance of the proposed method compared with classical method.

  9. Refinement procedure for the image alignment in high-resolution electron tomography

    International Nuclear Information System (INIS)

    Houben, L.; Bar Sadan, M.

    2011-01-01

    High-resolution electron tomography from a tilt series of transmission electron microscopy images requires an accurate image alignment procedure in order to maximise the resolution of the tomogram. This is the case in particular for ultra-high resolution where even very small misalignments between individual images can dramatically reduce the fidelity of the resultant reconstruction. A tomographic-reconstruction based and marker-free method is proposed, which uses an iterative optimisation of the tomogram resolution. The method utilises a search algorithm that maximises the contrast in tomogram sub-volumes. Unlike conventional cross-correlation analysis it provides the required correlation over a large tilt angle separation and guarantees a consistent alignment of images for the full range of object tilt angles. An assessment based on experimental reconstructions shows that the marker-free procedure is competitive to the reference of marker-based procedures at lower resolution and yields sub-pixel accuracy even for simulated high-resolution data. -- Highlights: → Alignment procedure for electron tomography based on iterative tomogram contrast optimisation. → Marker-free, independent of object, little user interaction. → Accuracy competitive with fiducial marker methods and suited for high-resolution tomography.

  10. Automated angular and translational tomographic alignment and application to phase-contrast imaging

    DEFF Research Database (Denmark)

    Cunha Ramos, Tiago Joao; Jørgensen, Jakob Sauer; Andreasen, Jens Wenzel

    2017-01-01

    X-ray computerized tomography (CT) is a 3D imaging technique that makes use of x-ray illumination and image reconstruction techniques to reproduce the internal cross-sections of a sample. Tomographic projection data usually require an initial relative alignment or knowledge of the exact object po...... improvement in the reconstruction resolution. A MATLAB implementation is made publicly available and will allow robust analysis of large volumes of phase-contrast tomography data.......X-ray computerized tomography (CT) is a 3D imaging technique that makes use of x-ray illumination and image reconstruction techniques to reproduce the internal cross-sections of a sample. Tomographic projection data usually require an initial relative alignment or knowledge of the exact object...... reconstruction artifacts and limit the attained resolution in the final tomographic reconstruction. Alignment algorithms that require manual interaction impede data analysis with ever-increasing data acquisition rates, supplied by more brilliant sources. We present in this paper an iterative reconstruction...

  11. Quality assurance of CT-PET alignment and image registration for radiation treatment planning

    International Nuclear Information System (INIS)

    Gong, S.J.; O'Keefe, G.J.; Gunawardana, D.H.

    2005-01-01

    A multi-layer point source phantom was first used to calibrate and verify the CT-PET system alignment. A partial whole-body Aldcrson RANDO Man Phantom (head through mid-femur) was externally and internally marked with small metal cannulas filled with 18F-FDG and then scanned with both modalities. Six series of phantom studies with different acquisition settings and scan positions were performed to reveal possible system bias and evaluate the accuracy and reliabilities of Philips Syntegra program in image alignment, coregistration and fusion. The registration error was assessed quantitatively by measuring the root-mean-square distance between the iso-centers of corresponding fiducial marker geometries in reference CT volumes and transformed CT or PET volumes. Results: Experimental data confirms the accuracy of manual, parameter, point and image-based registration using Syntegra is better than 2 mm. Comparisons between blind and cross definition of iso-centers of fiducial marks indicate that the fused CT and PET is superior to visual correlation of CT and PET side-by-side. Conclusion: In this work we demonstrate the QA procedures of Gemini image alignment and registration. Syntegra produces intrinsic and robust multi-modality image registration and fusion with careful user interaction. The registration accuracy is generally better than the spatial resolution of the PET scanner used and this appears to be sufficient for most RTP CT-PET registration procedures

  12. Effect of rectal enema on intrafraction prostate movement during image-guided radiotherapy.

    Science.gov (United States)

    Choi, Youngmin; Kwak, Dong-Won; Lee, Hyung-Sik; Hur, Won-Joo; Cho, Won-Yeol; Sung, Gyung Tak; Kim, Tae-Hyo; Kim, Soo-Dong; Yun, Seong-Guk

    2015-04-01

    Rectal volume and movement are major factors that influence prostate location. The aim of this study was to assess the effect of a rectal enema on intrafraction prostate motion. The data from 12 patients with localised prostate cancer were analysed. Each patient underwent image-guided radiotherapy (RT), receiving a total dose of 70 Gy in 28 fractions. Rectal enemas were administered to all of the patients before each RT fraction. The location of the prostate was determined by implanting three fiducial markers under the guidance of transrectal ultrasound. Each patient underwent preparation for IGRT twice before an RT fraction and in the middle of the fraction. The intrafraction displacement of the prostate was calculated by comparing fiducial marker locations before and in the middle of an RT fraction. The rectal enemas were well tolerated by patients. The mean intrafraction prostate movement in 336 RT fractions was 1.11 ± 0.77 mm (range 0.08-7.20 mm). Intrafraction motions of 1, 2 and 3 mm were observed in 56.0%, 89.0% and 97.6% of all RT fractions, respectively. The intrafraction movements on supero-inferior and anteroposterior axes were larger than on the right-to-left axes (P movement, calculated using the van Herk formula (2.5Σ + 0.7σ), was 1.50 mm. A daily rectal enema before each RT fraction was tolerable and yielded little intrafraction prostate displacement. We think the use of rectal enemas is a feasible method to reduce prostate movement during RT. © 2014 The Royal Australian and New Zealand College of Radiologists.

  13. Effect of rectal enema on intrafraction prostate movement during image-guided radiotherapy

    International Nuclear Information System (INIS)

    Choi, Youngmin; Kwak, Dong-Won; Lee, Hyung-Sik; Hur, Won-Jooh; Cho, Won-Yeol; Sung, Gyung Tak; Kim, Tae-Hyo; Kim, Soo-Dong; Yun, Seong-Guk

    2015-01-01

    Rectal volume and movement are major factors that influence prostate location. The aim of this study was to assess the effect of a rectal enema on intrafraction prostate motion. The data from 12 patients with localised prostate cancer were analysed. Each patient underwent image-guided radiotherapy (RT), receiving a total dose of 70 Gy in 28 fractions. Rectal enemas were administered to all of the patients before each RT fraction. The location of the prostate was determined by implanting three fiducial markers under the guidance of transrectal ultrasound. Each patient underwent preparation for IGRT twice before an RT fraction and in the middle of the fraction. The intrafraction displacement of the prostate was calculated by comparing fiducial marker locations before and in the middle of an RT fraction. The rectal enemas were well tolerated by patients. The mean intrafraction prostate movement in 336 RT fractions was 1.11 ± 0.77 mm (range 0.08–7.20 mm). Intrafraction motions of 1, 2 and 3 mm were observed in 56.0%, 89.0% and 97.6% of all RT fractions, respectively. The intrafraction movements on supero-inferior and anteroposterior axes were larger than on the right-to-left axes (P < 0.05). The CTV-to-PTV margin necessary to allow for movement, calculated using the van Herk formula (2.5Σ + 0.7σ), was 1.50 mm. A daily rectal enema before each RT fraction was tolerable and yielded little intrafraction prostate displacement. We think the use of rectal enemas is a feasible method to reduce prostate movement during RT.

  14. Synthesis and assessment methods for an edge-alignment-free hybrid image

    Science.gov (United States)

    Sripian, Peeraya; Yamaguchi, Yasushi

    2017-07-01

    A hybrid image allows multiple image interpretations to be modulated by the viewing distance. It can be constructed on the basis of the multiscale perceptual mechanisms of the human visual system by combining the low and high spatial frequencies of two different images. The hybrid image was introduced as an experimental tool for visual recognition study in terms of spatial frequency perception. To produce a compelling hybrid image, the original hybrid image synthesis method could only use similar shapes of source images that were aligned in the edges. If any two different images can be hybrid, it would be beneficial as a new experimental tool. In addition, there is no measure for the actual perception of spatial frequency, whether a single spatial frequency or both spatial frequencies are perceived from the hybrid stimulus. This paper describes two methods for synthesizing a hybrid image from dissimilar shape images or unaligned images; this hybrid image is known as an "edge-alignment-free hybrid image." A noise-inserted method can be done by intentionally inserting and enhancing noises into the high-frequency image. With this method, the low-frequency blobs are covered with high-frequency noises when viewed up close. A color-inserted method uses complementary color gratings in the background of the high-frequency image to emphasize the high-frequency image when viewed up close, whereas the gratings disappear when viewed from far away. To ascertain that our approach successfully separates the spatial frequency at each viewing distance, we measured this property using our proposed assessment method. Our proposed method allows the experimenter to quantify the probability of perceiving both spatial frequencies and a single spatial frequency in a hybrid image. The experimental results confirmed that our proposed synthesis methods successfully hid the low-frequency image and emphasized the high-frequency image at a close viewing distance. At the same time, the

  15. Prostate gland motion assessed with cine-magnetic resonance imaging (cine-MRI)

    International Nuclear Information System (INIS)

    Ghilezan, Michel J.; Jaffray, David A.; Siewerdsen, Jeffrey H.; Herk, Marcel van; Shetty, Anil; Sharpe, Michael B.; Zafar Jafri, Syed; Vicini, Frank A.; Matter, Richard C.; Brabbins, Donald S.; Martinez, Alvaro A.

    2005-01-01

    Purpose: To quantify prostate motion during a radiation therapy treatment using cine-magnetic resonance imaging (cine-MRI) for time frames comparable to that expected in an image-guided radiation therapy treatment session (20-30 min). Materials and Methods: Six patients undergoing radiation therapy for prostate cancer were imaged on 3 days, over the course of therapy (Weeks 1, 3, and 5). Four hundred images were acquired during the 1-h MRI session in 3 sagittal planes through the prostate at 6-s intervals. Eleven anatomic points of interest (POIs) have been used to characterize prostate/bony pelvis/abdominal wall displacement. Motion traces and standard deviation for each of the 11 POIs have been determined. The probability of displacement over time has also been calculated. Results: Patients were divided into 2 groups according to rectal filling status: full vs. empty rectum. The displacement of POIs (standard deviation) ranged from 0.98 to 1.72 mm for the full-rectum group and from 0.68 to 1.04 mm for the empty-rectum group. The low standard deviations in position (2 mm or less) would suggest that these excursions have a low frequency of occurrence. The most sensitive prostate POI to rectal wall motion was the midposterior with a standard deviation of 1.72 mm in the full-rectum group vs. 0.79 mm in the empty-rectum group (p 0.0001). This POI has a 10% probability of moving more than 3 mm in a time frame of ∼1 min if the rectum is full vs. ∼20 min if the rectum is empty. Conclusion: Motion of the prostate and seminal vesicles during a time frame similar to a standard treatment session is reduced compared to that reported in interfraction studies. The most significant predictor for intrafraction prostate motion is the status of rectal filling. A prostate displacement of <3 mm (90%) can be expected for the 20 min after the moment of initial imaging for patients with an empty rectum. This is not the case for patients presenting with full rectum. The determination

  16. Automated prostate cancer detection via comprehensive multi-parametric magnetic resonance imaging texture feature models

    International Nuclear Information System (INIS)

    Khalvati, Farzad; Wong, Alexander; Haider, Masoom A.

    2015-01-01

    Prostate cancer is the most common form of cancer and the second leading cause of cancer death in North America. Auto-detection of prostate cancer can play a major role in early detection of prostate cancer, which has a significant impact on patient survival rates. While multi-parametric magnetic resonance imaging (MP-MRI) has shown promise in diagnosis of prostate cancer, the existing auto-detection algorithms do not take advantage of abundance of data available in MP-MRI to improve detection accuracy. The goal of this research was to design a radiomics-based auto-detection method for prostate cancer via utilizing MP-MRI data. In this work, we present new MP-MRI texture feature models for radiomics-driven detection of prostate cancer. In addition to commonly used non-invasive imaging sequences in conventional MP-MRI, namely T2-weighted MRI (T2w) and diffusion-weighted imaging (DWI), our proposed MP-MRI texture feature models incorporate computed high-b DWI (CHB-DWI) and a new diffusion imaging modality called correlated diffusion imaging (CDI). Moreover, the proposed texture feature models incorporate features from individual b-value images. A comprehensive set of texture features was calculated for both the conventional MP-MRI and new MP-MRI texture feature models. We performed feature selection analysis for each individual modality and then combined best features from each modality to construct the optimized texture feature models. The performance of the proposed MP-MRI texture feature models was evaluated via leave-one-patient-out cross-validation using a support vector machine (SVM) classifier trained on 40,975 cancerous and healthy tissue samples obtained from real clinical MP-MRI datasets. The proposed MP-MRI texture feature models outperformed the conventional model (i.e., T2w+DWI) with regard to cancer detection accuracy. Comprehensive texture feature models were developed for improved radiomics-driven detection of prostate cancer using MP-MRI. Using a

  17. Extreme Hypofractionated Image-Guided Radiotherapy for Prostate Cancer

    Directory of Open Access Journals (Sweden)

    Carlo Greco

    2013-09-01

    Full Text Available An emerging body of data suggests that hypofractionated radiation schedules, where a higher dose per fraction is delivered in a smaller number of sessions, may be superior to conventional fractionation schemes in terms of both tumour control and toxicity profile in the management of adenocarcinoma of the prostate. However, the optimal hypofractionation scheme is still the subject of scientific debate. Modern computer-driven technology enables the safe implementation of extreme hypo fractionation (often referred to as stereotactic body radiation therapy [SBRT]. Several studies are currently being conducted to clarify the yet unresolved issues regarding treatment techniques and fractionation regimens. Recently, the American Society for Radiation Oncology (ASTRO issued a model policy indicating that data supporting the use of SBRT for prostate cancer have matured to a point where SBRT could be considered an appropriate alternative for select patients with low-to-intermediate risk disease. The present article reviews some of the currently available data and examines the impact of tracking technology to mitigate intra-fraction target motion, thus, potentially further improving the clinical outcomes of extreme hypofractionated radiation therapy in appropriately selected prostate cancer patients. The Champalimaud Centre for the Unknown (CCU’s currently ongoing Phase I feasibility study is described; it delivers 45 Gy in five fractions using prostate fixation via a rectal balloon, and urethral sparing via catheter placement with on-line intra-fractional motion tracking through beacon transponder technology.

  18. Magnetic resonance imaging basics for the prostate brachytherapist

    DEFF Research Database (Denmark)

    Wang, Jihong; Tanderup, Kari; Cunha, Adam

    2017-01-01

    . Terminology and MRI system components are reviewed along with typical work flows in prostate high-dose-rate and low-dose-rate brachytherapy. In general, the brachytherapy workflow consists of five key components: diagnosis, implantation, treatment planning (scan + plan), implant verification, and delivery...

  19. Choline-PET/CT for imaging prostate cancer; Cholin-PET/CT zur Bildgebung des Prostatakarzinoms

    Energy Technology Data Exchange (ETDEWEB)

    Krause, Bernd Joachim [Klinik- und Poliklinik fuer Nuklearmedizin, Klinikum rechts der Isar, Technische Univ. Muenchen (Germany); Treiber, U.; Schwarzenboeck, S.; Souvatzoglou, M. [Klinik fuer Urologie, Klinikum rechts der Isar, Technische Univ. Muenchen (Germany)

    2010-09-15

    PET and PET/CT using [{sup 11}C]- and [{sup 18}F]-labelled choline derivatives are increasingly being used for imaging of prostate cancer. The value of PET and PET/CT with [{sup 11}C]- and [{sup 18}F]-labelled choline derivates in biochemical recurrence of prostate cancer has been examined in many studies and demonstrates an increasing importance. Primary prostate cancer can be detected with moderate sensitivity using PET and PET/CT using [{sup 11}C]- and [{sup 18}F]-labelled choline derivatives - the differentiation between benign prostatic hyperplasia, prostatitis or high-grade intraepithelial neoplasia (HGPIN) is not always possible. At the present time [{sup 11}C]choline PET/CT is not recommended in the primary setting but may be utilized in clinically suspected prostate cancer with repeatedly negative prostate biopsies, in preparation of a focused re-biopsy. Promising results have been obtained for the use of PET and PET/CT with [{sup 11}C]- and [{sup 18}F]-labelled choline derivates in patients with biochemical recurrence. The detection rate of choline PET and PET/CT for local, regional, and distant recurrence in patients with a biochemical recurrence shows a linear correlation with PSA values at the time of imaging and reaches about 75% in patients with PSA > 3 ng/mL. At PSA values below 1 ng/mL, the recurrence can be diagnosed with choline PET/CT in approximately 1/3 of the patients. PET and PET/CT with [{sup 11}C]- and [{sup 18}F]choline derivates can be helpful for choosing a therapeutic strategy in the sense of an individualized treatment: since an early diagnosis of recurrence is crucial to the choice of optimal treatment. The localization of the site of recurrence - local recurrence, lymph node metastasis or systemic dissemination - has important influence on the therapy regimen. (orig.)

  20. 3D non-rigid surface-based MR-TRUS registration for image-guided prostate biopsy

    Science.gov (United States)

    Sun, Yue; Qiu, Wu; Romagnoli, Cesare; Fenster, Aaron

    2014-03-01

    Two dimensional (2D) transrectal ultrasound (TRUS) guided prostate biopsy is the standard approach for definitive diagnosis of prostate cancer (PCa). However, due to the lack of image contrast of prostate tumors needed to clearly visualize early-stage PCa, prostate biopsy often results in false negatives, requiring repeat biopsies. Magnetic Resonance Imaging (MRI) has been considered to be a promising imaging modality for noninvasive identification of PCa, since it can provide a high sensitivity and specificity for the detection of early stage PCa. Our main objective is to develop and validate a registration method of 3D MR-TRUS images, allowing generation of volumetric 3D maps of targets identified in 3D MR images to be biopsied using 3D TRUS images. Our registration method first makes use of an initial rigid registration of 3D MR images to 3D TRUS images using 6 manually placed approximately corresponding landmarks in each image. Following the manual initialization, two prostate surfaces are segmented from 3D MR and TRUS images and then non-rigidly registered using a thin-plate spline (TPS) algorithm. The registration accuracy was evaluated using 4 patient images by measuring target registration error (TRE) of manually identified corresponding intrinsic fiducials (calcifications and/or cysts) in the prostates. Experimental results show that the proposed method yielded an overall mean TRE of 2.05 mm, which is favorably comparable to a clinical requirement for an error of less than 2.5 mm.

  1. Evaluating the cancer detection and grading potential of prostatic-zinc imaging: a simulation study

    International Nuclear Information System (INIS)

    Cortesi, M; Chechik, R; Breskin, A; Vartsky, D; Ramon, J; Raviv, G; Volkov, A; Fridman, E

    2009-01-01

    The present work deals with the analysis of prostatic-zinc-concentration images. The goal is to evaluate potential clinically relevant information that can be extracted from such images. In the absence of experimental images, synthetic ones are produced from clinically measured zinc-concentration distributions in certified benign and cancerous tissue samples, classified by the lesion grade. We describe the method for producing the images and model the effect of counting statistics noise. We present in detail the image analysis, which is based on a combination of standard image processing and segmentation tools, optimized for this particular application. The information on lowest zinc value obtained from the image analysis is translated to clinical data such as tumour presence, location, size and grade. Their confidence is evaluated with the help of standard statistical tools such as receiver operating characteristic analysis. The present work predicts a potential for detecting small prostate-cancer lesions, of grade (4+3) and above, with very good specificity and sensitivity. The present analysis further provides data on the pixel size and image counting statistics requested from the trans-rectal probe that will record in vivo prostatic-zinc maps in patients.

  2. Clinically low-risk prostate cancer: evaluation with transrectal doppler ultrasound and functional magnetic resonance imaging

    Directory of Open Access Journals (Sweden)

    Maria Inês Novis

    2011-01-01

    Full Text Available OBJECTIVES: To evaluate transrectal ultrasound, amplitude Doppler ultrasound, conventional T2-weighted magnetic resonance imaging, spectroscopy and dynamic contrast-enhanced magnetic resonance imaging in localizing and locally staging low-risk prostate cancer. INTRODUCTION: Prostate cancer has been diagnosed at earlier stages and the most accepted classification for low-risk prostate cancer is based on clinical stage T1c or T2a, Gleason score <6, and prostate-specific antigen (PSA <10 ng/ml. METHODS: From 2005 to 2006, magnetic resonance imaging was performed in 42 patients, and transrectal ultrasound in 26 of these patients. Seven patients were excluded from the study. Mean patient age was 64.94 years and mean serum PSA was 6.05 ng/ml. The examinations were analyzed for tumor identification and location in prostate sextants, detection of extracapsular extension, and seminal vesicle invasion, using surgical pathology findings as the gold standard. RESULTS: Sixteen patients (45.7% had pathologically proven organ-confined disease, 11 (31.4% had positive surgical margin, 8 (28.9% had extracapsular extension, and 3 (8.6% presented with extracapsular extension and seminal vesicle invasion. Sensitivity, specificity, positive predictive value (PPV, negative predictive value (NPV and accuracy values for localizing low-risk prostate cancer were 53.1%, 48.3%, 63.4%, 37.8% and 51.3% for transrectal ultrasound; 70.4%, 36.2%, 65.1%, 42.0% and 57.7% for amplitude Doppler ultrasound; 71.5%, 58.9%, 76.6%, 52.4% and 67.1% for magnetic resonance imaging; 70.4%, 58.7%, 78.4%, 48.2% and 66.7% for magnetic resonance spectroscopy; 67.2%, 65.7%, 79.3%, 50.6% and 66.7% for dynamic contrast-enhanced magnetic resonance imaging, respectively. Sensitivity, specificity, PPV, NPV and accuracy values for detecting extracapsular extension were 33.3%, 92%, 14.3%, 97.2% and 89.7% for transrectal ultrasound and 50.0%, 77.6%, 13.7%, 95.6% and 75.7% for magnetic resonance imaging

  3. The role of positron emission tomography/computed tomography imaging with radiolabeled choline analogues in prostate cancer.

    Science.gov (United States)

    Navarro-Pelayo Láinez, M M; Rodríguez-Fernández, A; Gómez-Río, M; Vázquez-Alonso, F; Cózar-Olmo, J M; Llamas-Elvira, J M

    2014-11-01

    prostate cancer is the most frequent solid malignant tumor in Western Countries. Positron emission tomography/x-ray computed tomography imaging with radiolabeled choline analogues is a useful tool for restaging prostate cancer in patients with rising prostate-specific antigen after radical treatment (in whom conventional imaging techniques have important limitations) as well as in the initial assessment of a selected group of prostate cancer patients. For this reason a literature review is necessary in order to evaluate the usefulness of this imaging test for the diagnosis and treatment of prostate cancer. a MEDLINE (PubMed way) literature search was performed using the search parameters: «Prostate cancer» and «Choline-PET/CT». Other search terms were «Biochemical failure» and/or «Staging» and/or «PSA kinetics». English and Spanish papers were selected; original articles, reviews, systematic reviews and clinical guidelines were included. according to available data, radiolabeled choline analogues plays an important role in the management of prostate cancer, especially in biochemical relapse because technique accuracy is properly correlated with prostate-specific antigen values and kinetics. Although is an emerging diagnostic technique useful in treatment planning of prostate cancer, final recommendations have not been submitted. Copyright © 2013 AEU. Published by Elsevier Espana. All rights reserved.

  4. Prostate cancer in magnetic resonance imaging: diagnostic utilites of spectroscopic sequences

    International Nuclear Information System (INIS)

    Caivano, Rocchina; Cirillo, Patrizia; Lotumolo, Antonella; Fortunato, Giovanna; Zandolino, Alexis; Cammarota, Aldo; Balestra, Antonio; Macarini, Luca; Vita, Giulia

    2012-01-01

    The aim of our work is to determine the efficacy of a combined study 3 Tesla Magnetic Resonance Imaging (3T MRI), with phased-array coil, for the detection of prostate cancer using magnetic resonance spectroscopy (MRS) and diffusion-weighted images (DWI) in identifying doubt nodules. In this study, we prospectively studied 46 patients who consecutively underwent digital-rectal exploration for high doses of prostate specific antigen (PSA), as well as a MRI examination and a subsequent rectal biopsy. The study of magnetic resonance imaging was performed with a Philips Achieva 3T scanner and phased-array coil. The images were obtained with turbo spin-echo sequences T2-weighted images, T1-weighted before and after the administration of contrast medium, DWI sequences and 3D spectroscopic sequences. The ultrasound-guided prostate biopsy was performed approximately 15 days after the MRI. The data obtained from MR images and spectroscopy were correlated with histological data. MRI revealed sensitivity and specificity of 88% and 61% respectively and positive predictive value (PPV) of 73%, negative predicted value (NPV) of 81% and accuracy of 76%. In identifying the location of prostate cancer, the sensitivity of 3T MRS was 92%, with a specificity of 89%, PPV of 87%, NPV of 88% and accuracy of 87%; DWI showed a sensitivity of 88%, specificity of 61%, PPV of 73%, NPV of 81% and accuracy of 76%. The 3T MR study with phased-array coil and the use of DWI and spectroscopic sequences, in addition to T2-weighted sequences, revealed to be accurate in the diagnosis of prostate cancer and in the identification of nodules to be biopsied. It may be indicated as a resolute way before biopsy in patients with elevated PSA value and can be proposed in the staging and follow-up.

  5. Quality control of system of imaging for rectal ultrasound for implants seed prostate low rate

    International Nuclear Information System (INIS)

    Luquero Llopis, N.; Ferrer Gracia, C.; Huertas Martinez, C.; Huerga Cabrerizo, C.; Corredoira Silva, E.; Serrada Hierro, A.

    2013-01-01

    In this work, the objective is the evaluation of the image system used in implants of prostate of low rate held at our hospital, for maximum control on the placement of the seeds in the patient and therefore carried out dosimetry. (Author)

  6. Voxel-wise prostate cell density prediction using multiparametric magnetic resonance imaging and machine learning.

    Science.gov (United States)

    Sun, Yu; Reynolds, Hayley M; Wraith, Darren; Williams, Scott; Finnegan, Mary E; Mitchell, Catherine; Murphy, Declan; Haworth, Annette

    2018-04-26

    There are currently no methods to estimate cell density in the prostate. This study aimed to develop predictive models to estimate prostate cell density from multiparametric magnetic resonance imaging (mpMRI) data at a voxel level using machine learning techniques. In vivo mpMRI data were collected from 30 patients before radical prostatectomy. Sequences included T2-weighted imaging, diffusion-weighted imaging and dynamic contrast-enhanced imaging. Ground truth cell density maps were computed from histology and co-registered with mpMRI. Feature extraction and selection were performed on mpMRI data. Final models were fitted using three regression algorithms including multivariate adaptive regression spline (MARS), polynomial regression (PR) and generalised additive model (GAM). Model parameters were optimised using leave-one-out cross-validation on the training data and model performance was evaluated on test data using root mean square error (RMSE) measurements. Predictive models to estimate voxel-wise prostate cell density were successfully trained and tested using the three algorithms. The best model (GAM) achieved a RMSE of 1.06 (± 0.06) × 10 3 cells/mm 2 and a relative deviation of 13.3 ± 0.8%. Prostate cell density can be quantitatively estimated non-invasively from mpMRI data using high-quality co-registered data at a voxel level. These cell density predictions could be used for tissue classification, treatment response evaluation and personalised radiotherapy.

  7. Metabolite ratios in 1H MR spectroscopic imaging of the prostate

    NARCIS (Netherlands)

    Kobus, T.; Wright, A.J.; Weiland, E.; Heerschap, A.; Scheenen, T.W.J.

    2015-01-01

    In (1)H MR spectroscopic imaging ((1)H-MRSI) of the prostate the spatial distribution of the signal levels of the metabolites choline, creatine, polyamines, and citrate are assessed. The ratio of choline (plus spermine as the main polyamine) plus creatine over citrate [(Cho+(Spm+)Cr)/Cit] is derived

  8. Development of High Field MR Imaging and Spectroscopy Techniques of the Prostate

    NARCIS (Netherlands)

    Arteaga de Castro, C.S.

    2013-01-01

    This thesis summarizes the work of the development of new techniques for obtaining magnetic resonance imaging (MRI) and spectroscopy (MRS) of the prostate at the ultra high field of 7 tesla (T). The 7 T field strength presents various challenges such as the shortening of the wavelength and the lower

  9. Preliminary results of endorectal surface coil magnetic resonance imaging for local staging of prostate cancer

    NARCIS (Netherlands)

    Jager, G. J.; Barentsz, J. O.; de la Rosette, J. J.; Rosenbusch, G.

    1994-01-01

    To evaluate the effectiveness of endorectal surface coil (ERC) magnetic resonance imaging (MRI) in the local staging of adenocarcinoma of the prostate (ACP). A total of 23 patients who were considered candidates for radical prostatectomy because of clinically localized ACP were examined by ERC-MRI.

  10. Preclinical Study on GRPR-Targeted (68)Ga-Probes for PET Imaging of Prostate Cancer

    DEFF Research Database (Denmark)

    Sun, Yao; Ma, Xiaowei; Zhang, Zhe

    2016-01-01

    Gastrin-releasing peptide receptor (GRPR) targeted positron emission tomography (PET) is a highly promising approach for imaging of prostate cancer (PCa) in small animal models and patients. Developing a GRPR-targeted PET probe with excellent in vivo performance such as high tumor uptake, high...

  11. Automatic prostate localization on cone-beam CT scans for high precision image-guided radiotherapy

    NARCIS (Netherlands)

    Smitsmans, Monique H. P.; de Bois, Josien; Sonke, Jan-Jakob; Betgen, Anja; Zijp, Lambert J.; Jaffray, David A.; Lebesque, Joos V.; van Herk, Marcel

    2005-01-01

    PURPOSE: Previously, we developed an automatic three-dimensional gray-value registration (GR) method for fast prostate localization that could be used during online or offline image-guided radiotherapy. The method was tested on conventional computed tomography (CT) scans. In this study, the

  12. Multi-parametric MR imaging for prostate carcinoma; Multiparametrische MR-Bildgebung beim Prostatakarzinom

    Energy Technology Data Exchange (ETDEWEB)

    Schlemmer, Heinz-Peter [Deutsches Krebsforschungszentrum, Heidelberg (Germany). Abt. Radiologie

    2017-03-15

    Multi-parametric NMR imaging in case of prostate carcinoma can improve diagnostics, allows reliable prognostic estimations and helps to find the optimum individual therapy. The contribution is focused to deliver the needed methodological tools and background knowledge for the daily routine.

  13. Oligometastatic prostate cancer: shaping the definition with molecular imaging and an improved understanding of tumor biology.

    Science.gov (United States)

    Joice, Gregory A; Rowe, Steven P; Pienta, Kenneth J; Gorin, Michael A

    2017-11-01

    The aim of this review is to discuss how novel imaging modalities and molecular markers are shaping the definition of oligometastatic prostate cancer. To effectively classify a patient as having oligometastatic prostate cancer, diagnostic tests must be sensitive enough to detect subtle sites of metastatic disease. Conventional imaging modalities can readily detect widespread polymetastatic disease but do not have the sensitivity necessary to reliably classify patients as oligometastatic. Molecular imaging using both metabolic- and molecularly-targeted radiotracers has demonstrated great promise in aiding in our ability to define the oligometastatic state. Perhaps the most promising data to date have been generated with radiotracers targeting prostate-specific membrane antigen. In addition, early studies are beginning to define biologic markers in the oligometastatic state that may be indicative of disease with minimal metastatic potential. Recent developments in molecular imaging have allowed for improved detection of metastatic prostate cancer allowing for more accurate staging of patients with oligometastatic disease. Future development of biologic markers may assist in defining the oligometastatic state and determining prognosis.

  14. Axial loaded stress views and kinematic MR imaging evaluation of patellar alignment and tracking

    International Nuclear Information System (INIS)

    Shellock, F.G.; Mink, J.H.; Deutsch, A.; Meeks, T.; Fox, J.; Molnar, T.

    1990-01-01

    This paper evaluates patellar alignment and tracking in patients with suspected abnormalities by obtaining axial loaded stress views to assess dynamic stabilizers and kinematic MR images to assess static stabilizers of the patellofemoral joint. Ninety-eight symptomatic joints were studied; 21 joints had prior realignment surgery. Axial loaded stress views were achieved with a device that simulated weight bearing. Images were obtained with knees flexed at 20 degrees ± 5 degrees while the patient resisted with an isometric contraction. Kinematic MR imaging was performed according to previously described methods. Kinematic MR imaging showed normal findings in six joints, lateral subluxation in 22, medial subluxation in 58, lateral tilt in two, and lateral to medial subluxation in 10. Axial stress views showed normal findings in 30, lateral subluxation in 18, and medial subluxation in 50. Both tests agreed on abnormalities for 63% of the joints, while kinematic MR imaging showed abnormalities for an additional 32%

  15. Image stack alignment in full-field X-ray absorption spectroscopy using SIFT_PyOCL.

    Science.gov (United States)

    Paleo, Pierre; Pouyet, Emeline; Kieffer, Jérôme

    2014-03-01

    Full-field X-ray absorption spectroscopy experiments allow the acquisition of millions of spectra within minutes. However, the construction of the hyperspectral image requires an image alignment procedure with sub-pixel precision. While the image correlation algorithm has originally been used for image re-alignment using translations, the Scale Invariant Feature Transform (SIFT) algorithm (which is by design robust versus rotation, illumination change, translation and scaling) presents an additional advantage: the alignment can be limited to a region of interest of any arbitrary shape. In this context, a Python module, named SIFT_PyOCL, has been developed. It implements a parallel version of the SIFT algorithm in OpenCL, providing high-speed image registration and alignment both on processors and graphics cards. The performance of the algorithm allows online processing of large datasets.

  16. An efficient multi-resolution GA approach to dental image alignment

    Science.gov (United States)

    Nassar, Diaa Eldin; Ogirala, Mythili; Adjeroh, Donald; Ammar, Hany

    2006-02-01

    Automating the process of postmortem identification of individuals using dental records is receiving an increased attention in forensic science, especially with the large volume of victims encountered in mass disasters. Dental radiograph alignment is a key step required for automating the dental identification process. In this paper, we address the problem of dental radiograph alignment using a Multi-Resolution Genetic Algorithm (MR-GA) approach. We use location and orientation information of edge points as features; we assume that affine transformations suffice to restore geometric discrepancies between two images of a tooth, we efficiently search the 6D space of affine parameters using GA progressively across multi-resolution image versions, and we use a Hausdorff distance measure to compute the similarity between a reference tooth and a query tooth subject to a possible alignment transform. Testing results based on 52 teeth-pair images suggest that our algorithm converges to reasonable solutions in more than 85% of the test cases, with most of the error in the remaining cases due to excessive misalignments.

  17. Automatic Prostate Tracking and Motion Assessment in Volumetric Modulated Arc Therapy With an Electronic Portal Imaging Device

    International Nuclear Information System (INIS)

    Azcona, Juan Diego; Li, Ruijiang; Mok, Edward; Hancock, Steven; Xing, Lei

    2013-01-01

    Purpose: To assess the prostate intrafraction motion in volumetric modulated arc therapy treatments using cine megavoltage (MV) images acquired with an electronic portal imaging device (EPID). Methods and Materials: Ten prostate cancer patients were treated with volumetric modulated arc therapy using a Varian TrueBeam linear accelerator equipped with an EPID for acquiring cine MV images during treatment. Cine MV images acquisition was scheduled for single or multiple treatment fractions (between 1 and 8). A novel automatic fiducial detection algorithm that can handle irregular multileaf collimator apertures, field edges, fast leaf and gantry movement, and MV image noise and artifacts in patient anatomy was used. All sets of images (approximately 25,000 images in total) were analyzed to measure the positioning accuracy of implanted fiducial markers and assess the prostate movement. Results: Prostate motion can vary greatly in magnitude among different patients. Different motion patterns were identified, showing its unpredictability. The mean displacement and standard deviation of the intrafraction motion was generally less than 2.0 ± 2.0 mm in each of the spatial directions. In certain patients, however, the percentage of the treatment time in which the prostate is displaced more than 5 mm from its planned position in at least 1 spatial direction was 10% or more. The maximum prostate displacement observed was 13.3 mm. Conclusion: Prostate tracking and motion assessment was performed with MV imaging and an EPID. The amount of prostate motion observed suggests that patients will benefit from its real-time monitoring. Megavoltage imaging can provide the basis for real-time prostate tracking using conventional linear accelerators

  18. Alignment of large image series using cubic B-splines tessellation: application to transmission electron microscopy data.

    Science.gov (United States)

    Dauguet, Julien; Bock, Davi; Reid, R Clay; Warfield, Simon K

    2007-01-01

    3D reconstruction from serial 2D microscopy images depends on non-linear alignment of serial sections. For some structures, such as the neuronal circuitry of the brain, very large images at very high resolution are necessary to permit reconstruction. These very large images prevent the direct use of classical registration methods. We propose in this work a method to deal with the non-linear alignment of arbitrarily large 2D images using the finite support properties of cubic B-splines. After initial affine alignment, each large image is split into a grid of smaller overlapping sub-images, which are individually registered using cubic B-splines transformations. Inside the overlapping regions between neighboring sub-images, the coefficients of the knots controlling the B-splines deformations are blended, to create a virtual large grid of knots for the whole image. The sub-images are resampled individually, using the new coefficients, and assembled together into a final large aligned image. We evaluated the method on a series of large transmission electron microscopy images and our results indicate significant improvements compared to both manual and affine alignment.

  19. Prostate Ultrasound

    Medline Plus

    Full Text Available ... through blood vessels. Ultrasound imaging is a noninvasive medical test that helps physicians diagnose and treat medical conditions. Prostate ultrasound, also called transrectal ultrasound, provides ...

  20. Automatic prostate localization on cone-beam CT scans for high precision image-guided radiotherapy

    International Nuclear Information System (INIS)

    Smitsmans, Monique H.P.; Bois, Josien de; Sonke, Jan-Jakob; Betgen, Anja; Zijp, Lambert J.; Jaffray, David A.; Lebesque, Joos V.; Herk, Marcel van

    2005-01-01

    Purpose: Previously, we developed an automatic three-dimensional gray-value registration (GR) method for fast prostate localization that could be used during online or offline image-guided radiotherapy. The method was tested on conventional computed tomography (CT) scans. In this study, the performance of the algorithm to localize the prostate on cone-beam CT (CBCT) scans acquired on the treatment machine was evaluated. Methods and Materials: Five to 17 CBCT scans of 32 prostate cancer patients (332 scans in total) were used. For 18 patients (190 CBCT scans), the CBCT scans were acquired with a collimated field of view (FOV) (craniocaudal). This procedure improved the image quality considerably. The prostate (i.e., prostate plus seminal vesicles) in each CBCT scan was registered to the prostate in the planning CT scan by automatic 3D gray-value registration (normal GR) starting from a registration on the bony anatomy. When these failed, registrations were repeated with a fixed rotation point locked at the prostate apex (fixed apex GR). Registrations were visually assessed in 3D by one observer with the help of an expansion (by 3.6 mm) of the delineated prostate contours of the planning CT scan. The percentage of successfully registered cases was determined from the combined normal and fixed apex GR assessment results. The error in gray-value registration for both registration methods was determined from the position of one clearly defined calcification in the prostate gland (9 patients, 71 successful registrations). Results: The percentage of successfully registered CBCT scans that were acquired with a collimated FOV was about 10% higher than for CBCT scans that were acquired with an uncollimated FOV. For CBCT scans that were acquired with a collimated FOV, the percentage of successfully registered cases improved from 65%, when only normal GR was applied, to 83% when the results of normal and fixed apex GR were combined. Gray-value registration mainly failed (or

  1. Automated detection of a prostate Ni-Ti stent in electronic portal images

    OpenAIRE

    Carl, Jesper; Nielsen, Henning; Nielsen, Jane; Lund, Bente; Larsen, Erik Hoejkjaer

    2006-01-01

      Udgivelsesdato: DEC  Planning target volumes (PTV) in fractionated radiotherapy still have to be outlined with wide margins to the clinical target volume due to uncertainties arising from daily shift of the prostate position. A recently proposed new method of visualization of the prostate is based on insertion of a thermo-expandable Ni-Ti stent. The current study proposes a new detection algorithm for automated detection of the Ni-Ti stent in electronic portal images. The algorithm is ba...

  2. The method for glomerulations detection in histological images of prostate

    Science.gov (United States)

    Zavarzin, A. A.; Pronichev, A. N.; Rodionova, O. V.; Komochkina, E. A.; Prilepskaya, E. A.; Kovylina, M. V.

    2018-01-01

    In the work presented, a method for detecting glomeruli in pictures of histological preparations of the prostate gland is described, the presence of which indicates a malignant neoplasm. Pathological structures at the level of microimages are investigated. The developed method is the result of joint activity of the National Research Nuclear University "MEPhI" and the Moscow State Medical and Stomatological University named after A.I. Evdokimova.

  3. Fusing MRI and Mechanical Imaging for Improved Prostate Cancer Diagnosis

    Science.gov (United States)

    2016-10-01

    paradigm. The spatial prior probability is calculated in the training phase, and is used to estimate the texture feature parameters corresponding to...active shape model ( ASM ) is introduced and applied in the new 3D TURS representation for prostate segmentation. Figure 1 demonstrates the framework of...generating the foreground and background heat-map per texture feature. Figure 2. The probability heatmap of (a) the foreground probability and

  4. WE-EF-210-07: Development of a Minimally Invasive Photo Acoustic Imaging System for Early Prostate Cancer Detection

    Energy Technology Data Exchange (ETDEWEB)

    Sano, M; Yousefi, S; Xing, L [Stanford University School of Medicine, Stanford, CA (United States)

    2015-06-15

    Purpose: The objective of this work is to design, implement and characterize a catheter-based ultrasound/photoacoustic imaging probe for early-diagnosis of prostate cancer and to aid in image-guided radiation therapy. Methods: The need to image across 6–10cm of tissue to image the whole prostate gland limits the resolution achievable with a transrectal ultrasound approach. In contrast, the urethra bisects the prostate gland, providing a minimally invasive pathway for deploying a high resolution ultrasound transducer. Utilizing a high-frequency (20MHz) ultrasound/photoacoustic probe, high-resolution structural and molecular imaging of the prostate tissue is possible. A custom 3D printed probe containing a high-frequency single-element ultrasound transducer is utilized. The diameter of the probe is designed to fit inside a Foley catheter and the probe is rotated around the central axis to achieve a circular B-scan. A custom ultrasound amplifier and receiver was set up to trigger the ultrasound pulse transmission and record the reflected signal. The reconstructed images were compared to images generated by traditional 5 MHz ultrasound transducers. Results: The preliminary results using the high-frequency ultrasound probe show that it is possible to resolve finely detailed information in a prostate tissue phantom that was not achievable with previous low-frequency ultrasound systems. Preliminary ultrasound imaging was performed on tissue mimicking phantom and sensitivity and signal-to-noise ratio of the catheter was measured. Conclusion: In order to achieve non-invasive, high-resolution, structural and molecular imaging for early-diagnosis and image-guided radiation therapy of the prostate tissue, a transurethral catheter was designed. Structural/molecular imaging using ultrasound/photoacoustic of the prostate tissue will allow for localization of hyper vascularized areas for early-stage prostate cancer diagnosis.

  5. Prostate contouring uncertainty in megavoltage computed tomography images acquired with a helical tomotherapy unit during image-guided radiation therapy

    International Nuclear Information System (INIS)

    Song, William Y.; Chiu, Bernard; Bauman, Glenn S.; Lock, Michael; Rodrigues, George; Ash, Robert; Lewis, Craig; Fenster, Aaron; Battista, Jerry J.; Van Dyk, Jake

    2006-01-01

    Purpose: To evaluate the image-guidance capabilities of megavoltage computed tomography (MVCT), this article compares the interobserver and intraobserver contouring uncertainty in kilovoltage computed tomography (KVCT) used for radiotherapy planning with MVCT acquired with helical tomotherapy. Methods and Materials: Five prostate-cancer patients were evaluated. Each patient underwent a KVCT and an MVCT study, a total of 10 CT studies. For interobserver variability analysis, four radiation oncologists, one physicist, and two radiation therapists (seven observers in total) contoured the prostate and seminal vesicles (SV) in the 10 studies. The intraobserver variability was assessed by asking all observers to repeat the contouring of 1 patient's KVCT and MVCT studies. Quantitative analysis of contour variations was performed by use of volumes and radial distances. Results: The interobserver and intraobserver contouring uncertainty was larger in MVCT compared with KVCT. Observers consistently segmented larger volumes on MVCT where the ratio of average prostate and SV volumes was 1.1 and 1.2, respectively. On average (interobserver and intraobserver), the local delineation variability, in terms of standard deviations [Δσ = √(σ 2 MVCT - σ 2 KVCT )], increased by 0.32 cm from KVCT to MVCT. Conclusions: Although MVCT was inferior to KVCT for prostate delineation, the application of MVCT in prostate radiotherapy remains useful

  6. Synchronous rectal and prostate cancer – The impact of MRI on incidence and imaging findings

    International Nuclear Information System (INIS)

    Sturludóttir, Margrét; Martling, Anna; Carlsson, Stefan; Blomqvist, Lennart

    2015-01-01

    Highlights: •Prostate and rectal cancers are two of the most common cancers in male. •Synchronous diagnosis of prostate and rectal cancer is a rare identity. •Strong increase in the synchronous diagnosis likely due to improved diagnostic methods. •Pre-treatment MRI for rectal cancer has led to increased synchronous diagnosis. -- Abstract: Objective: To evaluate the incidence of synchronous diagnosis of rectal and prostate cancer and to identify how the role of magnetic resonance imaging (MRI) for preoperative staging of rectal cancer has affected the incidence. Methods: Regional data from the Swedish Colorectal Cancer Registry and the Regional Cancer Registry in Stockholm-Gotland area (two million inhabitants) between the years 1995–2011 were used. Patients were included when the rectal cancer was diagnosed prior to the prostate cancer. Medical records and pre-treatment MRI were retrospectively reviewed. Results: Of 29,849 patients diagnosed with either disease, synchronous diagnosis was made in 29 patients (0.1%). Two patients were diagnosed in the years 1995–1999, seven patients between the years 2000–2005 and 20 patients between the years 2006–2011. The most common presentation, for the prostate cancer was incidental finding during staging for rectal cancer, n = 20, and of those led MRI to the diagnosis in 14 cases. At retrospective review, all patients had focal lesions in the prostate on MRI and patients with higher suspicion of malignancy on MRI had more locally advanced disease. Conclusion: Synchronous rectal and prostate cancer are a rare entity, but a strong increase in synchronous diagnosis is seen which may be attributed to improved diagnostic methods, including the use of pre-treatment MRI in routine work-up for rectal cancer

  7. Synchronous rectal and prostate cancer – The impact of MRI on incidence and imaging findings

    Energy Technology Data Exchange (ETDEWEB)

    Sturludóttir, Margrét, E-mail: margret.sturludottir@karolinska.se [Department of Radiology, Karolinska University Hospital, 17176 Solna (Sweden); Martling, Anna, E-mail: anna.martling@ki.se [Center of Surgical Gastroenterology, Karolinska University Hospital, 17176 Solna (Sweden); Department of Molecular Medicine and Surgery, Karolinska Institutet, 17177 Solna (Sweden); Carlsson, Stefan, E-mail: stefan.carlsson@ki.se [Department of Urology, Karolinska University Hospital, 17176 Solna (Sweden); Department of Molecular Medicine and Surgery, Karolinska Institutet, 17177 Solna (Sweden); Blomqvist, Lennart, E-mail: lennart.k.blomqvist@ki.se [Department of Radiology, Karolinska University Hospital, 17176 Solna (Sweden); Department of Molecular Medicine and Surgery, Karolinska Institutet, 17177 Solna (Sweden)

    2015-04-15

    Highlights: •Prostate and rectal cancers are two of the most common cancers in male. •Synchronous diagnosis of prostate and rectal cancer is a rare identity. •Strong increase in the synchronous diagnosis likely due to improved diagnostic methods. •Pre-treatment MRI for rectal cancer has led to increased synchronous diagnosis. -- Abstract: Objective: To evaluate the incidence of synchronous diagnosis of rectal and prostate cancer and to identify how the role of magnetic resonance imaging (MRI) for preoperative staging of rectal cancer has affected the incidence. Methods: Regional data from the Swedish Colorectal Cancer Registry and the Regional Cancer Registry in Stockholm-Gotland area (two million inhabitants) between the years 1995–2011 were used. Patients were included when the rectal cancer was diagnosed prior to the prostate cancer. Medical records and pre-treatment MRI were retrospectively reviewed. Results: Of 29,849 patients diagnosed with either disease, synchronous diagnosis was made in 29 patients (0.1%). Two patients were diagnosed in the years 1995–1999, seven patients between the years 2000–2005 and 20 patients between the years 2006–2011. The most common presentation, for the prostate cancer was incidental finding during staging for rectal cancer, n = 20, and of those led MRI to the diagnosis in 14 cases. At retrospective review, all patients had focal lesions in the prostate on MRI and patients with higher suspicion of malignancy on MRI had more locally advanced disease. Conclusion: Synchronous rectal and prostate cancer are a rare entity, but a strong increase in synchronous diagnosis is seen which may be attributed to improved diagnostic methods, including the use of pre-treatment MRI in routine work-up for rectal cancer.

  8. Prospective MR image alignment between breath-holds: Application to renal BOLD MRI.

    Science.gov (United States)

    Kalis, Inge M; Pilutti, David; Krafft, Axel J; Hennig, Jürgen; Bock, Michael

    2017-04-01

    To present an image registration method for renal blood oxygen level-dependent (BOLD) measurements that enables semiautomatic assessment of parenchymal and medullary R2* changes under a functional challenge. In a series of breath-hold acquisitions, three-dimensional data were acquired initially for prospective image registration of subsequent BOLD measurements. An algorithm for kidney alignment for BOLD renal imaging (KALIBRI) was implemented to detect the positions of the left and right kidney so that the kidneys were acquired in the subsequent BOLD measurement at consistent anatomical locations. Residual in-plane distortions were corrected retrospectively so that semiautomatic dynamic R2* measurements of the renal cortex and medulla become feasible. KALIBRI was tested in six healthy volunteers during a series of BOLD experiments, which included a 600- to 1000-mL water challenge. Prospective image registration and BOLD imaging of each kidney was achieved within a total measurement time of about 17 s, enabling its execution within a single breath-hold. KALIBRI improved the registration by up to 35% as found with mutual information measures. In four volunteers, a medullary R2* decrease of up to 40% was observed after water ingestion. KALIBRI improves the quality of two-dimensional time-resolved renal BOLD MRI by aligning local renal anatomy, which allows for consistent R2* measurements over many breath-holds. Magn Reson Med 77:1573-1582, 2017. © 2016 International Society for Magnetic Resonance in Medicine. © 2016 International Society for Magnetic Resonance in Medicine.

  9. Magnetic resonance spectroscopy imaging in the diagnosis of prostate cancer: initial experience

    International Nuclear Information System (INIS)

    Melo, Homero Jose de Farias e; Abdala, Nitamar; Goldman, Suzan Menasce; Szejnfeld, Jacob

    2009-01-01

    Objective: to report an experiment involving the introduction of a protocol utilizing commercially available three-dimensional 1H magnetic resonance spectroscopy imaging (3D 1H MRSI) method in patients diagnosed with prostatic tumors under suspicion of neoplasm. Materials and methods: forty-one patients in the age range between 51 and 80 years (mean, 67 years) were prospectively evaluated. The patients were divided into two groups: patients with one or more biopsies negative for cancer and high specific-prostatic antigen levels (group A), and patients with cancer confirmed by biopsy (group B). The determination of the target area (group A) or the known cancer extent (group B) was based on magnetic resonance imaging and MRSI studies. Results: the specificity of MRSI in the diagnosis of prostate cancer was lower than the specificity reported in the literature (about 47%). On the other hand, for tumor staging, it corresponded to the specificity reported in the literature. Conclusion: the introduction and standardization of 3D 1H MRSI has allowed the obtention of a presumable diagnosis of prostate cancer, by a combined analysis of magnetic resonance imaging and metabolic data from 3D 1H MRSI. (author)

  10. Learning statistical correlation for fast prostate registration in image-guided radiotherapy

    International Nuclear Information System (INIS)

    Shi Yonghong; Liao Shu; Shen Dinggang

    2011-01-01

    Purpose: In adaptive radiation therapy of prostate cancer, fast and accurate registration between the planning image and treatment images of the patient is of essential importance. With the authors' recently developed deformable surface model, prostate boundaries in each treatment image can be rapidly segmented and their correspondences (or relative deformations) to the prostate boundaries in the planning image are also established automatically. However, the dense correspondences on the nonboundary regions, which are important especially for transforming the treatment plan designed in the planning image space to each treatment image space, are remained unresolved. This paper presents a novel approach to learn the statistical correlation between deformations of prostate boundary and nonboundary regions, for rapidly estimating deformations of the nonboundary regions when given the deformations of the prostate boundary at a new treatment image. Methods: The main contributions of the proposed method lie in the following aspects. First, the statistical deformation correlation will be learned from both current patient and other training patients, and further updated adaptively during the radiotherapy. Specifically, in the initial treatment stage when the number of treatment images collected from the current patient is small, the statistical deformation correlation is mainly learned from other training patients. As more treatment images are collected from the current patient, the patient-specific information will play a more important role in learning patient-specific statistical deformation correlation to effectively reflect prostate deformation of the current patient during the treatment. Eventually, only the patient-specific statistical deformation correlation is used to estimate dense correspondences when a sufficient number of treatment images have been acquired from the current patient. Second, the statistical deformation correlation will be learned by using a

  11. Automated image alignment for 2D gel electrophoresis in a high-throughput proteomics pipeline.

    Science.gov (United States)

    Dowsey, Andrew W; Dunn, Michael J; Yang, Guang-Zhong

    2008-04-01

    The quest for high-throughput proteomics has revealed a number of challenges in recent years. Whilst substantial improvements in automated protein separation with liquid chromatography and mass spectrometry (LC/MS), aka 'shotgun' proteomics, have been achieved, large-scale open initiatives such as the Human Proteome Organization (HUPO) Brain Proteome Project have shown that maximal proteome coverage is only possible when LC/MS is complemented by 2D gel electrophoresis (2-DE) studies. Moreover, both separation methods require automated alignment and differential analysis to relieve the bioinformatics bottleneck and so make high-throughput protein biomarker discovery a reality. The purpose of this article is to describe a fully automatic image alignment framework for the integration of 2-DE into a high-throughput differential expression proteomics pipeline. The proposed method is based on robust automated image normalization (RAIN) to circumvent the drawbacks of traditional approaches. These use symbolic representation at the very early stages of the analysis, which introduces persistent errors due to inaccuracies in modelling and alignment. In RAIN, a third-order volume-invariant B-spline model is incorporated into a multi-resolution schema to correct for geometric and expression inhomogeneity at multiple scales. The normalized images can then be compared directly in the image domain for quantitative differential analysis. Through evaluation against an existing state-of-the-art method on real and synthetically warped 2D gels, the proposed analysis framework demonstrates substantial improvements in matching accuracy and differential sensitivity. High-throughput analysis is established through an accelerated GPGPU (general purpose computation on graphics cards) implementation. Supplementary material, software and images used in the validation are available at http://www.proteomegrid.org/rain/.

  12. MR diffusion weighted imaging of the prostate adenocarcinoma after endocrinotherapy: preliminary results

    International Nuclear Information System (INIS)

    Chen Zhiqiang; Wang Xiaoying; Li Feiyu; Guo Xuemei; Jiang Xuexiang; Guo Yulin

    2007-01-01

    Objective: To assess the changes of the apparent diffusion coefficient (ADC) values of cancerous and noncancerous regions of prostate peripheral zone in prostate cancer patients with and without endocrinotherapy. Methods: Diffusion-weighted echo-planar imaging (EPI) were performed in 32 patients with diagnosed prostate cancer, including 18 patients who were treated with endocrinotherapy over 6 months and 14 untreated matched control patients. According to the pathological results obtained by ultrasound guided biopsy, the locations of the prostate cancerous regions were marked at one or more of the sextants. The ADC values of the bladder and the obturator internus were also measured. Results: The mean ADC values of cancerous and noncancerous regions in 14 untreated controls were (1.22±0.25) x 10 -3 , (1.59 ± 0.19) x 10 -3 mm 2 /s, respectively (t=7.03, P -3 mm 2 /s in noncancerous regions, but increased to (1.46 ± 0.30) x 10 -3 mm 2 /s in cancerous regions. There still had significant difference between the cancerous and the noncancerous regions (t=2.46, P 0.05), in bladder and the obturator internus (t=0.48, 1.64; P>0.05). Conclusion: Measurement of ADCs might be useful to evaluate the efficacy of endocrinotherapy for patients with prostate cancer. (authors)

  13. 18F-DCFBC Prostate-Specific Membrane Antigen-Targeted PET/CT Imaging in Localized Prostate Cancer: Correlation With Multiparametric MRI and Histopathology.

    Science.gov (United States)

    Turkbey, Baris; Mena, Esther; Lindenberg, Liza; Adler, Stephen; Bednarova, Sandra; Berman, Rose; Ton, Anita T; McKinney, Yolanda; Eclarinal, Philip; Hill, Craig; Afari, George; Bhattacharyya, Sibaprasad; Mease, Ronnie C; Merino, Maria J; Jacobs, Paula M; Wood, Bradford J; Pinto, Peter A; Pomper, Martin G; Choyke, Peter L

    2017-10-01

    To assess the ability of (N-[N-[(S)-1,3-dicarboxypropyl]carbamoyl]-4-F-fluorobenzyl-L-cysteine) (F-DCFBC), a prostate-specific membrane antigen-targeted PET agent, to detect localized prostate cancer lesions in correlation with multiparametric MRI (mpMRI) and histopathology. This Health Insurance Portability and Accountability Act of 1996-compliant, prospective, institutional review board-approved study included 13 evaluable patients with localized prostate cancer (median age, 62.8 years [range, 51-74 years]; median prostate-specific antigen, 37.5 ng/dL [range, 3.26-216 ng/dL]). Patients underwent mpMRI and F-DCFBC PET/CT within a 3 months' window. Lesions seen on mpMRI were biopsied under transrectal ultrasound/MRI fusion-guided biopsy, or a radical prostatectomy was performed. F-DCFBC PET/CT and mpMRI were evaluated blinded and separately for tumor detection on a lesion basis. For PET image analysis, MRI and F-DCFBC PET images were fused by using software registration; imaging findings were correlated with histology, and uptake of F-DCFBC in tumors was compared with uptake in benign prostatic hyperplasia nodules and normal peripheral zone tissue using the 80% threshold SUVmax. A total of 25 tumor foci (mean size, 1.8 cm; median size, 1.5 cm; range, 0.6-4.7 cm) were histopathologically identified in 13 patients. Sensitivity rates of F-DCFBC PET/CT and mpMRI were 36% and 96%, respectively, for all tumors. For index lesions, the largest tumor with highest Gleason score, sensitivity rates of F-DCFBC PET/CT and mpMRI were 61.5% and 92%, respectively. The average SUVmax for primary prostate cancer was higher (5.8 ± 4.4) than that of benign prostatic hyperplasia nodules (2.1 ± 0.3) or that of normal prostate tissue (2.1 ± 0.4) at 1 hour postinjection (P = 0.0033). The majority of index prostate cancers are detected with F-DCFBC PET/CT, and this may be a prognostic indicator based on uptake and staging. However, for detecting prostate cancer with high sensitivity, it

  14. A hybrid strategy of offline adaptive planning and online image guidance for prostate cancer radiotherapy

    International Nuclear Information System (INIS)

    Lei Yu; Wu Qiuwen

    2010-01-01

    Offline adaptive radiotherapy (ART) has been used to effectively correct and compensate for prostate motion and reduce the required margin. The efficacy depends on the characteristics of the patient setup error and interfraction motion through the whole treatment; specifically, systematic errors are corrected and random errors are compensated for through the margins. In online image-guided radiation therapy (IGRT) of prostate cancer, the translational setup error and inter-fractional prostate motion are corrected through pre-treatment imaging and couch correction at each fraction. However, the rotation and deformation of the target are not corrected and only accounted for with margins in treatment planning. The purpose of this study was to investigate whether the offline ART strategy is necessary for an online IGRT protocol and to evaluate the benefit of the hybrid strategy. First, to investigate the rationale of the hybrid strategy, 592 cone-beam-computed tomography (CBCT) images taken before and after each fraction for an online IGRT protocol from 16 patients were analyzed. Specifically, the characteristics of prostate rotation were analyzed. It was found that there exist systematic inter-fractional prostate rotations, and they are patient specific. These rotations, if not corrected, are persistent through the treatment fraction, and rotations detected in early fractions are representative of those in later fractions. These findings suggest that the offline adaptive replanning strategy is beneficial to the online IGRT protocol with further margin reductions. Second, to quantitatively evaluate the benefit of the hybrid strategy, 412 repeated helical CT scans from 25 patients during the course of treatment were included in the replanning study. Both low-risk patients (LRP, clinical target volume, CTV = prostate) and intermediate-risk patients (IRP, CTV = prostate + seminal vesicles) were included in the simulation. The contours of prostate and seminal vesicles were

  15. Imaging and intervention in prostate cancer: Current perspectives and future trends

    Directory of Open Access Journals (Sweden)

    Sanjay Sharma

    2014-01-01

    Full Text Available Prostate cancer is the commonest malignancy in men that causes significant morbidity and mortality worldwide. Screening by digital rectal examination (DRE and serum prostate-specific antigen (PSA is used despite its limitations. Gray-scale transrectal ultrasound (TRUS, used to guide multiple random prostatic biopsies, misses up to 20% cancers and frequently underestimates the grade of malignancy. Increasing the number of biopsy cores marginally increases the yield. Evolving techniques of real-time ultrasound elastography (RTE and contrast-enhanced ultrasound (CEUS are being investigated to better detect and improve the yield by allowing "targeted" biopsies. Last decade has witnessed rapid developments in magnetic resonance imaging (MRI for improved management of prostate cancer. In addition to the anatomical information, it is capable of providing functional information through diffusion-weighted imaging (DWI, magnetic resonance spectroscopy (MRS, and dynamic contrast-enhanced (DCE MRI. Multi-parametric MRI has the potential to exclude a significant cancer in majority of cases. Inclusion of MRI before prostatic biopsy can reduce the invasiveness of the procedure by limiting the number of cores needed to make a diagnosis and support watchful waiting in others. It is made possible by targeted biopsies as opposed to random. With the availability of minimally invasive therapeutic modalities like high-intensity focused ultrasound (HIFU and interstitial laser therapy, detecting early cancer is even more relevant today. [18F]--fluorodeoxyglucose positron emission tomography/computed tomography ( 18 FDG PET/CT has no role in the initial evaluation of prostate cancer. Choline PET has been recently found to be more useful. Fluoride-PET has a higher sensitivity and resolution than a conventional radionuclide bone scan in detecting skeletal metastases.

  16. Evaluation of GMI and PMI diffeomorphic‐based demons algorithms for aligning PET and CT Images

    Science.gov (United States)

    Yang, Juan; Zhang, You; Yin, Yong

    2015-01-01

    Fusion of anatomic information in computed tomography (CT) and functional information in F18‐FDG positron emission tomography (PET) is crucial for accurate differentiation of tumor from benign masses, designing radiotherapy treatment plan and staging of cancer. Although current PET and CT images can be acquired from combined F18‐FDG PET/CT scanner, the two acquisitions are scanned separately and take a long time, which may induce potential positional errors in global and local caused by respiratory motion or organ peristalsis. So registration (alignment) of whole‐body PET and CT images is a prerequisite for their meaningful fusion. The purpose of this study was to assess the performance of two multimodal registration algorithms for aligning PET and CT images. The proposed gradient of mutual information (GMI)‐based demons algorithm, which incorporated the GMI between two images as an external force to facilitate the alignment, was compared with the point‐wise mutual information (PMI) diffeomorphic‐based demons algorithm whose external force was modified by replacing the image intensity difference in diffeomorphic demons algorithm with the PMI to make it appropriate for multimodal image registration. Eight patients with esophageal cancer(s) were enrolled in this IRB‐approved study. Whole‐body PET and CT images were acquired from a combined F18‐FDG PET/CT scanner for each patient. The modified Hausdorff distance (dMH) was used to evaluate the registration accuracy of the two algorithms. Of all patients, the mean values and standard deviations (SDs) of dMH were 6.65 (± 1.90) voxels and 6.01 (± 1.90) after the GMI‐based demons and the PMI diffeomorphic‐based demons registration algorithms respectively. Preliminary results on oncological patients showed that the respiratory motion and organ peristalsis in PET/CT esophageal images could not be neglected, although a combined F18‐FDG PET/CT scanner was used for image acquisition. The PMI

  17. Evaluation of GMI and PMI diffeomorphic-based demons algorithms for aligning PET and CT Images.

    Science.gov (United States)

    Yang, Juan; Wang, Hongjun; Zhang, You; Yin, Yong

    2015-07-08

    Fusion of anatomic information in computed tomography (CT) and functional information in 18F-FDG positron emission tomography (PET) is crucial for accurate differentiation of tumor from benign masses, designing radiotherapy treatment plan and staging of cancer. Although current PET and CT images can be acquired from combined 18F-FDG PET/CT scanner, the two acquisitions are scanned separately and take a long time, which may induce potential positional errors in global and local caused by respiratory motion or organ peristalsis. So registration (alignment) of whole-body PET and CT images is a prerequisite for their meaningful fusion. The purpose of this study was to assess the performance of two multimodal registration algorithms for aligning PET and CT images. The proposed gradient of mutual information (GMI)-based demons algorithm, which incorporated the GMI between two images as an external force to facilitate the alignment, was compared with the point-wise mutual information (PMI) diffeomorphic-based demons algorithm whose external force was modified by replacing the image intensity difference in diffeomorphic demons algorithm with the PMI to make it appropriate for multimodal image registration. Eight patients with esophageal cancer(s) were enrolled in this IRB-approved study. Whole-body PET and CT images were acquired from a combined 18F-FDG PET/CT scanner for each patient. The modified Hausdorff distance (d(MH)) was used to evaluate the registration accuracy of the two algorithms. Of all patients, the mean values and standard deviations (SDs) of d(MH) were 6.65 (± 1.90) voxels and 6.01 (± 1.90) after the GMI-based demons and the PMI diffeomorphic-based demons registration algorithms respectively. Preliminary results on oncological patients showed that the respiratory motion and organ peristalsis in PET/CT esophageal images could not be neglected, although a combined 18F-FDG PET/CT scanner was used for image acquisition. The PMI diffeomorphic-based demons

  18. Searching for prostate cancer by fully automated magnetic resonance imaging classification: deep learning versus non-deep learning.

    Science.gov (United States)

    Wang, Xinggang; Yang, Wei; Weinreb, Jeffrey; Han, Juan; Li, Qiubai; Kong, Xiangchuang; Yan, Yongluan; Ke, Zan; Luo, Bo; Liu, Tao; Wang, Liang

    2017-11-13

    Prostate cancer (PCa) is a major cause of death since ancient time documented in Egyptian Ptolemaic mummy imaging. PCa detection is critical to personalized medicine and varies considerably under an MRI scan. 172 patients with 2,602 morphologic images (axial 2D T2-weighted imaging) of the prostate were obtained. A deep learning with deep convolutional neural network (DCNN) and a non-deep learning with SIFT image feature and bag-of-word (BoW), a representative method for image recognition and analysis, were used to distinguish pathologically confirmed PCa patients from prostate benign conditions (BCs) patients with prostatitis or prostate benign hyperplasia (BPH). In fully automated detection of PCa patients, deep learning had a statistically higher area under the receiver operating characteristics curve (AUC) than non-deep learning (P = 0.0007 deep learning method and 0.70 (95% CI 0.63-0.77) for non-deep learning method, respectively. Our results suggest that deep learning with DCNN is superior to non-deep learning with SIFT image feature and BoW model for fully automated PCa patients differentiation from prostate BCs patients. Our deep learning method is extensible to image modalities such as MR imaging, CT and PET of other organs.

  19. Perceptions of masculinity and body image in men with prostate cancer: the role of exercise.

    Science.gov (United States)

    Langelier, David Michael; Cormie, Prue; Bridel, William; Grant, Christopher; Albinati, Natalia; Shank, Jena; Daun, Julia Teresa; Fung, Tak S; Davey, Colin; Culos-Reed, S Nicole

    2018-04-13

    The goal of this study was to explore the association between levels of exercise and patterns of masculinity, body image, and quality of life in men undergoing diverse treatment protocols for prostate cancer. Fifty men with prostate cancer (aged 42-86) completed self-report measures. Self-reported measures included the following: the Godin Leisure Time Exercise Questionnaire (GLTEQ), Masculine Self-esteem Scale (MSES), Personal Attributes Questionnaire (PAQ), Body Image Scale (BIS), and the Functional Assessment of Cancer Therapy-Prostate (FACT-P). Masculinity, body image, and quality of life scores were compared between men obtaining recommended levels of exercise (aerobic or resistance) and those not obtaining recommended level of exercise. Secondary outcomes included the association between masculinity, body image, and quality of life scores as they relate to exercise levels. There were significantly higher scores of masculinity (p < 0.01), physical well-being (p < 0.05), prostate cancer specific well-being (p < 0.05), and overall quality of life (p < 0.05) in those obtaining at least 150 min of moderate to vigorous aerobic exercise. In the 48% of men who had never received androgen deprivation therapy, significantly higher levels of masculinity, body image, and quality of life were observed in those meeting aerobic guidelines. Whether treatment includes androgen deprivation or not, men who participate in higher levels of aerobic exercises report higher levels of masculinity, improved body image, and quality of life than those who are inactive. Future longitudinal research is required evaluating exercise level and its effect on masculinity and body image.

  20. Design of an Image-Servo Mask Alignment System Using Dual CCDs with an XXY Stage

    Directory of Open Access Journals (Sweden)

    Chih-Jer Lin

    2016-02-01

    Full Text Available Mask alignment of photolithography technology is used in many applications, such as micro electro mechanical systems’ semiconductor process, printed circuits board, and flat panel display. As the dimensions of the product are getting smaller and smaller, the automatic mask alignment of photolithography is becoming more and more important. The traditional stacked XY-Θz stage is heavy and it has cumulative flatness errors due to its stacked assembly mechanism. The XXY stage has smaller cumulative error due to its coplanar design and it can move faster than the traditional XY-Θz stage. However, the relationship between the XXY stage’s movement and the commands of the three motors is difficult to compute, because the movements of the three motors on the same plane are coupling. Therefore, an artificial neural network is studied to establish a nonlinear mapping from the desired position and orientation of the stage to three motors’ commands. Further, this paper proposes an image-servo automatic mask alignment system, which consists of a coplanar XXY stage, dual GIGA-E CCDs with lens and a programmable automatic controller (PAC. Before preforming the compensation, a self-developed visual-servo provides the positioning information which is obtained from the image processing and pattern recognition according to the specified fiducial marks. To obtain better precision, two methods including the center of gravity method and the generalize Hough Transformation are studied to correct the shift positioning error.

  1. Prostate position relative to pelvic bony anatomy based on intraprostatic gold markers and electronic portal imaging

    International Nuclear Information System (INIS)

    Schallenkamp, John M.; Herman, Michael G.; Kruse, Jon J.; Pisansky, Thomas M.

    2005-01-01

    Purpose: To describe the relative positions and motions of the prostate, pelvic bony anatomy, and intraprostatic gold fiducial markers during daily electronic portal localization of the prostate. Methods and Materials: Twenty prostate cancer patients were treated supine with definitive external radiotherapy according to an on-line target localization protocol using three or four intraprostatic gold fiducial markers and an electronic portal imaging device. Daily pretherapy and through-treatment electronic portal images (EPIs) were obtained for each of four treatment fields. The patients' pelvic bony anatomy, intraprostatic gold markers, and a best visual match to the target (i.e., prostate) were identified on simulation digitally reconstructed radiographs and during daily treatment setup and delivery. These data provided quantitative inter- and intrafractional analysis of prostate motion, its position relative to the bony anatomy, and the individual intraprostatic fiducial markers. Treatment planning margins, with and without on-line localization, were subsequently compared. Results: A total of 22,266 data points were obtained from daily pretherapy and through-treatment EPIs. The pretherapy three-dimensional (3D) average displacement of the fiducial markers, as a surrogate for the prostate, was 5.6 mm, which improved to 2.8 mm after use of the localization protocol. The bony anatomy 3D average displacement was 4.4 mm both before and after localization to the prostate (p = 0.46). Along the superior-inferior (SI), anterior-posterior (AP), and right-left (RL) axes, the average prostate displacement improved from 2.5, 3.7, and 1.9 mm, respectively, before localization to 1.4, 1.6, and 1.1 mm after (all p < 0.001). The pretherapy to through-treatment position of the bony landmarks worsened from 1.7 to 2.5 mm (p < 0.001) in the SI axis, remained statistically unchanged at 2.8 mm (p = 0.39) in the AP axis, and improved from 2.0 to 1.2 mm in the RL axis (p < 0.001). There

  2. Rapid ex vivo imaging of PAIII prostate to bone tumor with SWIFT-MRI.

    Science.gov (United States)

    Luhach, Ihor; Idiyatullin, Djaudat; Lynch, Conor C; Corum, Curt; Martinez, Gary V; Garwood, Michael; Gillies, Robert J

    2014-09-01

    The limiting factor for MRI of skeletal/mineralized tissue is fast transverse relaxation. A recent advancement in MRI technology, SWIFT (Sweep Imaging with Fourier Transform), is emerging as a new approach to overcome this difficulty. Among other techniques like UTE, ZTE, and WASPI, the application of SWIFT technology has the strong potential to impact preclinical and clinical imaging, particularly in the context of primary or metastatic bone cancers because it has the added advantage of imaging water in mineralized tissues of bone allowing MRI images to be obtained of tissues previously visible only with modalities such as computed tomography (CT). The goal of the current study is to examine the feasibility of SWIFT for the assessment of the prostate cancer induced changes in bone formation (osteogenesis) and destruction (osteolysis) in ex vivo specimens. A luciferase expressing prostate cancer cell line (PAIII) or saline control was inoculated directly into the tibia of 6-week-old immunocompromised male mice. Tumor growth was assessed weekly for 3 weeks before euthanasia and dissection of the tumor bearing and sham tibias. The ex vivo mouse tibia specimens were imaged with a 9.4 Tesla (T) and 7T MRI systems. SWIFT images are compared with traditional gradient-echo and spin-echo MRI images as well as CT and histological sections. SWIFT images with nominal resolution of 78 μm are obtained with the tumor and different bone structures identified. Prostate cancer induced changes in the bone microstructure are visible in SWIFT images, which is supported by spin-echo, high resolution CT and histological analysis. SWIFT MRI is capable of high-quality high-resolution ex vivo imaging of bone tumor and surrounding bone and soft tissues. Furthermore, SWIFT MRI shows promise for in vivo bone tumor imaging, with the added benefits of nonexposure to ionizing radiation, quietness, and speed. Copyright © 2013 Wiley Periodicals, Inc.

  3. Refinement procedure for the image alignment in high-resolution electron tomography.

    Science.gov (United States)

    Houben, L; Bar Sadan, M

    2011-01-01

    High-resolution electron tomography from a tilt series of transmission electron microscopy images requires an accurate image alignment procedure in order to maximise the resolution of the tomogram. This is the case in particular for ultra-high resolution where even very small misalignments between individual images can dramatically reduce the fidelity of the resultant reconstruction. A tomographic-reconstruction based and marker-free method is proposed, which uses an iterative optimisation of the tomogram resolution. The method utilises a search algorithm that maximises the contrast in tomogram sub-volumes. Unlike conventional cross-correlation analysis it provides the required correlation over a large tilt angle separation and guarantees a consistent alignment of images for the full range of object tilt angles. An assessment based on experimental reconstructions shows that the marker-free procedure is competitive to the reference of marker-based procedures at lower resolution and yields sub-pixel accuracy even for simulated high-resolution data. Copyright © 2011 Elsevier B.V. All rights reserved.

  4. Magnetic resonance imaging in the radiation treatment planning of localized prostate cancer using intra-prostatic fiducial markers for computed tomography co-registration

    International Nuclear Information System (INIS)

    Parker, C.C.; Damyanovich, A.; Haycocks, T.; Haider, M.; Bayley, A.; Catton, C.N.

    2003-01-01

    Purpose: To assess the feasibility, and potential implications, of using intra-prostatic fiducial markers, rather than bony landmarks, for the co-registration of computed tomography (CT) and magnetic resonance (MR) images in the radiation treatment planning of localized prostate cancer. Methods: All men treated with conformal therapy for localized prostate cancer underwent routine pre-treatment insertion of prostatic fiducial markers to assist with gross target volume (GTV) delineation and to identify prostate positioning during therapy. Six of these men were selected for investigation. Phantom MRI measurements were obtained to quantify image distortion, to determine the most suitable gold alloy marker composition, and to identify the spin-echo sequences that optimized both marker identification and the contrast between the prostate and the surrounding tissues. The GTV for each patient was contoured independently by three radiation oncologists on axial planning CT slices, and on axial MRI slices fused to the CT slices by matching the implanted fiducial markers. From each set of contours the scan common volume (SCV), and the scan encompassing volume (SEV), were obtained. The ratio SEV/SCV for a given scan is a measure of inter-observer variation in contouring. For each of the 18 patient-observer combinations the observer common volume (OCV) and the observer encompassing volume (OEV) was obtained. The ratio OEV/OCV for a given patient-observer combination is a measure of the inter-modality variation in contouring. The distance from the treatment planning isocenter to the prostate contours was measured and the discrepancy between the CT- and the MR-defined contour recorded. The discrepancies between the CT- and MR-defined contours of the posterior prostate were recorded in the sagittal plane at 1-cm intervals above and below the isocenter. Results: Phantom measurements demonstrated trivial image distortion within the required field of view, and an 18K Au/Cu alloy to

  5. Monitoring Prostate Tumor Growth in an Orthotopic Mouse Model Using Three-Dimensional Ultrasound Imaging Technique

    Directory of Open Access Journals (Sweden)

    Jie Ni

    2016-02-01

    Full Text Available Prostate cancer (CaP is the most commonly diagnosed and the second leading cause of death from cancer in males in USA. Prostate orthotopic mouse model has been widely used to study human CaP in preclinical settings. Measurement of changes in tumor size obtained from noninvasive diagnostic images is a standard method for monitoring responses to anticancer modalities. This article reports for the first time the usage of a three-dimensional (3D ultrasound system equipped with photoacoustic (PA imaging in monitoring longitudinal prostate tumor growth in a PC-3 orthotopic NODSCID mouse model (n = 8. Two-dimensional and 3D modes of ultrasound show great ability in accurately depicting the size and shape of prostate tumors. PA function on two-dimensional and 3D images showed average oxygen saturation and average hemoglobin concentration of the tumor. Results showed a good fit in representative exponential tumor growth curves (n = 3; r2 = 0.948, 0.955, and 0.953, respectively and a good correlation of tumor volume measurements performed in vivo with autopsy (n = 8, r = 0.95, P < .001. The application of 3D ultrasound imaging proved to be a useful imaging modality in monitoring tumor growth in an orthotopic mouse model, with advantages such as high contrast, uncomplicated protocols, economical equipment, and nonharmfulness to animals. PA mode also enabled display of blood oxygenation surrounding the tumor and tumor vasculature and angiogenesis, making 3D ultrasound imaging an ideal tool for preclinical cancer research.

  6. Application of 11C-choline PET/CT imaging for differentiating malignant from benign prostate lesions

    International Nuclear Information System (INIS)

    Li Xin; Wang Muwen; Liu Qingwei; Zhu Renjuan; Liu Lihui; Yuan Xianshun; Yao Shuzhan; Liu Songtao

    2006-01-01

    Objective: To investigate the potential of 11 C-choline PET/CT imaging for differentiating prostate cancer from benign prostate hyperplasia. Methods: A total of 45 patients with prostate lesions under- went 11 C-choline PET/CT imaging before transrectal needle biopsy. PET/CT imaging was performed 5 min after injection of 7.4 MBq/kg 11 C-choline in supine position over lower abdomen (3 min per bed with 2 beds), including the pelvis, and the whole body with 6 beds when necessary. After attenuation correction and iterative reconstruction, PET data were analyzed semi-quantitatively by measuring maximum standardized uptake values (SUV max ) in prostate lesions (P, target) and the muscles (M, non-target) and then P/M ratios were calculated. Also visual analysis was performed in different transverse, sagittal views and slices as well as three-dimensional images. Results: Eighteen prostate cancer and 27 benign prostate hyperplasia [and(or) chronic prostatitis] were all confirmed by pathology. The mean P/M ratio of prostate cancer was 4.02± 1.88, while in benign lesions was 1.87±1.21. The statistical differences of P/M ratios between them were significant (t=2.07, P 11 C-choline PET/CT imaging were 88.89%, 88.89% and 92.31% respectively. Conclusions: 11 C-choline PET/CT imaging is a valuable non-invasive technology in the diagnosis of pros- tate cancer. The P/M ratio can differentiate prostate cancer from benign lesions better than SUV. (authors)

  7. Lesion volume predicts prostate cancer risk and aggressiveness: validation of its value alone and matched with prostate imaging reporting and data system score.

    Science.gov (United States)

    Martorana, Eugenio; Pirola, Giacomo Maria; Scialpi, Michele; Micali, Salvatore; Iseppi, Andrea; Bonetti, Luca Reggiani; Kaleci, Shaniko; Torricelli, Pietro; Bianchi, Giampaolo

    2017-07-01

    To demonstrate the association between magnetic resonance imaging (MRI) estimated lesion volume (LV), prostate cancer detection and tumour clinical significance, evaluating this variable alone and matched with Prostate Imaging Reporting and Data System version 2 (PI-RADS v2) score. We retrospectively analysed 157 consecutive patients, with at least one prior negative systematic prostatic biopsy, who underwent transperineal prostate MRI/ultrasonography fusion-targeted biopsy between January 2014 and February 2016. Suspicious lesions were delineated using a 'region of interest' and the system calculated prostate volume and LV. Patients were divided in groups considering LV (≤0.5, 0.5-1, ≥1 mL) and PI-RADS score (1-5). We considered clinically significant prostate cancer as all cancers with a Gleason score of ≥3 + 4 as suggested by PI-RADS v2. A direct comparison between MRI estimated LV (MRI LV) and histological tumour volume (HTV) was done in 23 patients who underwent radical prostatectomy during the study period. Differences between MRI LV and HTV were assessed using the paired sample t-test. MRI LV and HTV concordance was verified using a Bland-Altman plot. The chi-squared test and logistic and ordinal regression models were used to evaluate difference in frequencies. The MRI LV and PI-RADS score were associated both with prostate cancer detection (both P prostate cancer detection (P Prostate cancer detection was 1.4-times higher for LVs of 0.5-1 mL and 1.8-times higher for LVs of ≥1 mL; significant prostate cancer detection was 2.6-times for LVs of 0.5-1 mL and 4-times for LVs of ≥1 mL. There was a positive correlation between MRI LV and HTV (r = 0.9876, P prostate cancer detection and with tumour clinical significance. © 2016 The Authors BJU International © 2016 BJU International Published by John Wiley & Sons Ltd.

  8. Diagnostic value of MR diffusion weighted imaging in prostate cancer of central glands

    International Nuclear Information System (INIS)

    Xiao Lihua; Zheng Xiaolin; He Qiang; Luo Daosheng; Zhang Kunlin; Zou Yujian

    2010-01-01

    Objective: To discuss the diagnostic value of diffusion weighted imaging (DWI) in prostate cancer of central glands (CGPca) and differentiate from benign hyperlasia (BHP). Methods: All patients included 15 cases of prostate cancer of central glands and 20 cases of benign prostatic hyperplasia. DWI were obtained with factor b of 800 s/mm 2 . DWI and ADC map appearances were reviewed in all patients. ADC values of CGPca and PBH tissues were measured and analysed statistically. Results: All of 15 CGPca cases showed markedly markedly high-signal on DWI and low-signal on ADC map, both could clearly demonstrate the area of CGPca. But 6 cases were misdiagnosed as PBH by conventional imaging because of the tumors limited to central glands. The mean ADG values of CGPca cases and BPH cases were (0.93±0.13) x 10 -3 mm 2 /s and (11.53±0.12) x 10 -3 mm 2 /s respectively. There were significant differences in CGPca and BPH. Conclusion: It has an important clinical value in diagnosing prostate cancer of central glands and differentiating from BHP with DWI and ADC values. (authors)

  9. TH-CD-206-02: BEST IN PHYSICS (IMAGING): 3D Prostate Segmentation in MR Images Using Patch-Based Anatomical Signature

    International Nuclear Information System (INIS)

    Yang, X; Jani, A; Rossi, P; Mao, H; Curran, W; Liu, T

    2016-01-01

    Purpose: MRI has shown promise in identifying prostate tumors with high sensitivity and specificity for the detection of prostate cancer. Accurate segmentation of the prostate plays a key role various tasks: to accurately localize prostate boundaries for biopsy needle placement and radiotherapy, to initialize multi-modal registration algorithms or to obtain the region of interest for computer-aided detection of prostate cancer. However, manual segmentation during biopsy or radiation therapy can be time consuming and subject to inter- and intra-observer variation. This study’s purpose it to develop an automated method to address this technical challenge. Methods: We present an automated multi-atlas segmentation for MR prostate segmentation using patch-based label fusion. After an initial preprocessing for all images, all the atlases are non-rigidly registered to a target image. And then, the resulting transformation is used to propagate the anatomical structure labels of the atlas into the space of the target image. The top L similar atlases are further chosen by measuring intensity and structure difference in the region of interest around prostate. Finally, using voxel weighting based on patch-based anatomical signature, the label that the majority of all warped labels predict for each voxel is used for the final segmentation of the target image. Results: This segmentation technique was validated with a clinical study of 13 patients. The accuracy of our approach was assessed using the manual segmentation (gold standard). The mean volume Dice Overlap Coefficient was 89.5±2.9% between our and manual segmentation, which indicate that the automatic segmentation method works well and could be used for 3D MRI-guided prostate intervention. Conclusion: We have developed a new prostate segmentation approach based on the optimal feature learning label fusion framework, demonstrated its clinical feasibility, and validated its accuracy. This segmentation technique could be

  10. TH-CD-206-02: BEST IN PHYSICS (IMAGING): 3D Prostate Segmentation in MR Images Using Patch-Based Anatomical Signature

    Energy Technology Data Exchange (ETDEWEB)

    Yang, X; Jani, A; Rossi, P; Mao, H; Curran, W; Liu, T [Emory University, Atlanta, GA (United States)

    2016-06-15

    Purpose: MRI has shown promise in identifying prostate tumors with high sensitivity and specificity for the detection of prostate cancer. Accurate segmentation of the prostate plays a key role various tasks: to accurately localize prostate boundaries for biopsy needle placement and radiotherapy, to initialize multi-modal registration algorithms or to obtain the region of interest for computer-aided detection of prostate cancer. However, manual segmentation during biopsy or radiation therapy can be time consuming and subject to inter- and intra-observer variation. This study’s purpose it to develop an automated method to address this technical challenge. Methods: We present an automated multi-atlas segmentation for MR prostate segmentation using patch-based label fusion. After an initial preprocessing for all images, all the atlases are non-rigidly registered to a target image. And then, the resulting transformation is used to propagate the anatomical structure labels of the atlas into the space of the target image. The top L similar atlases are further chosen by measuring intensity and structure difference in the region of interest around prostate. Finally, using voxel weighting based on patch-based anatomical signature, the label that the majority of all warped labels predict for each voxel is used for the final segmentation of the target image. Results: This segmentation technique was validated with a clinical study of 13 patients. The accuracy of our approach was assessed using the manual segmentation (gold standard). The mean volume Dice Overlap Coefficient was 89.5±2.9% between our and manual segmentation, which indicate that the automatic segmentation method works well and could be used for 3D MRI-guided prostate intervention. Conclusion: We have developed a new prostate segmentation approach based on the optimal feature learning label fusion framework, demonstrated its clinical feasibility, and validated its accuracy. This segmentation technique could be

  11. Evaluation of Online/Offline Image Guidance/Adaptation Approaches for Prostate Cancer Radiation Therapy

    International Nuclear Information System (INIS)

    Qin, An; Sun, Ying; Liang, Jian; Yan, Di

    2015-01-01

    Purpose: To evaluate online/offline image-guided/adaptive treatment techniques for prostate cancer radiation therapy with daily cone-beam CT (CBCT) imaging. Methods and Materials: Three treatment techniques were evaluated retrospectively using daily pre- and posttreatment CBCT images on 22 prostate cancer patients. Prostate, seminal vesicles (SV), rectal wall, and bladder were delineated on all CBCT images. For each patient, a pretreatment intensity modulated radiation therapy plan with clinical target volume (CTV) = prostate + SV and planning target volume (PTV) = CTV + 3 mm was created. The 3 treatment techniques were as follows: (1) Daily Correction: The pretreatment intensity modulated radiation therapy plan was delivered after online CBCT imaging, and position correction; (2) Online Planning: Daily online inverse plans with 3-mm CTV-to-PTV margin were created using online CBCT images, and delivered; and (3) Hybrid Adaption: Daily Correction plus an offline adaptive inverse planning performed after the first week of treatment. The adaptive plan was delivered for all remaining 15 fractions. Treatment dose for each technique was constructed using the daily posttreatment CBCT images via deformable image registration. Evaluation was performed using treatment dose distribution in target and critical organs. Results: Treatment equivalent uniform dose (EUD) for the CTV was within [85.6%, 100.8%] of the pretreatment planned target EUD for Daily Correction; [98.7%, 103.0%] for Online Planning; and [99.2%, 103.4%] for Hybrid Adaptation. Eighteen percent of the 22 patients in Daily Correction had a target dose deficiency >5%. For rectal wall, the mean ± SD of the normalized EUD was 102.6% ± 2.7% for Daily Correction, 99.9% ± 2.5% for Online Planning, and 100.6% ± 2.1% for Hybrid Adaptation. The mean ± SD of the normalized bladder EUD was 108.7% ± 8.2% for Daily Correction, 92.7% ± 8.6% for Online Planning, and 89.4% ± 10.8% for Hybrid

  12. Transcription-Based Molecular Imaging and Gene Therapy for Castration-resistant and Metastatic Prostate Cancer in Translational Models

    OpenAIRE

    Jiang, Ziyue

    2013-01-01

    The advanced stage of prostate cancer is the second leading cause of cancer-related death for American men. Novel, effective treatment options and more cancer-specific diagnostic tools are urgently needed to facilitate patient management. Here, we explored the construction and application of an array of gene-based molecular imaging and therapeutic vectors in a variety of clinically relevant settings. These vectors exploit prostate cancer-specific promoters to control the transcription of imag...

  13. Development of a PET Prostate-Specific Membrane Antigen Imaging Agent: Preclinical Translation for Future Clinical Application

    Science.gov (United States)

    2017-10-01

    are those of the author(s) and should not be construed as an official Department of the Army position, policy or decision unless so designated by...phase 0) application to the FDA by the end of the funding period. The small molecule imaging agents under study home to prostate specific membrane...funding period. The small molecule imaging agents under study home to prostate specific membrane antigen (PSMA) that is prevalent on a majority of

  14. Magnetic resonance imaging-guided biopsies may improve diagnosis in biopsy-naive men with suspicion of prostate cancer

    DEFF Research Database (Denmark)

    Winther, Mads Dochedahl; Balslev, Ingegerd; Boesen, Lars

    2017-01-01

    INTRODUCTION: The purpose of this pilot study was to investigate whether a short prostate biparametric magnetic resonance imaging (bp-MRI) protocol provides a valuable diagnostic addition for biopsy guidance in biopsy-naive men with a suspicion of prostate cancer (PCa). METHODS: A total of 62...... biopsy-naive patients referred to a systematic transrectal ultrasound biopsy (TRUS-bx) due to suspicion of PCa were prospectively enrolled. Bp-MRI was performed before biopsy. All lesions were scored according to the modified Prostate Imaging Reporting and Data System (PI-RADS) version 2. All patients...

  15. Integrated manufacture of a freeform off-axis multi-reflective imaging system without optical alignment.

    Science.gov (United States)

    Li, Zexiao; Liu, Xianlei; Fang, Fengzhou; Zhang, Xiaodong; Zeng, Zhen; Zhu, Linlin; Yan, Ning

    2018-03-19

    Multi-reflective imaging systems find wide applications in optical imaging and space detection. However, it is faced with difficulties in adjusting the freeform mirrors with high accuracy to guarantee the optical function. Motivated by this, an alignment-free manufacture approach is proposed to machine the optical system. The direct optical performance-guided manufacture route is established without measuring the form error of freeform optics. An analytical model is established to investigate the effects of machine errors to serve the error identification and compensation in machining. Based on the integrated manufactured system, an ingenious self-designed testing configuration is constructed to evaluate the optical performance by directly measuring the wavefront aberration. Experiments are carried out to manufacture a three-mirror anastigmat, surface topographical details and optical performance shows agreement to the designed expectation. The final system works as an off-axis infrared imaging system. Results validate the feasibility of the proposed method to achieve excellent optical application.

  16. Combination of prostate imaging reporting and data system (PI-RADS) score and prostate-specific antigen (PSA) density predicts biopsy outcome in prostate biopsy naïve patients.

    Science.gov (United States)

    Washino, Satoshi; Okochi, Tomohisa; Saito, Kimitoshi; Konishi, Tsuzumi; Hirai, Masaru; Kobayashi, Yutaka; Miyagawa, Tomoaki

    2017-02-01

    To assess the value of the Prostate Imaging Reporting and Data System (PI-RADS) scoring system, for prostate multi-parametric magnetic resonance imaging (mpMRI) to detect prostate cancer, and classical parameters, such as prostate-specific antigen (PSA) level, prostate volume and PSA density, for predicting biopsy outcome in biopsy naïve patients who have suspected prostate cancer. Patients who underwent mpMRI at our hospital, and who had their first prostate biopsy between July 2010 and April 2014, were analysed retrospectively. The prostate biopsies were taken transperineally under transrectal ultrasonography guidance. In all, 14 cores were biopsied as a systematic biopsy in all patients. Two cognitive fusion-targeted biopsy cores were added for each lesion in patients who had suspicious or equivocal lesions on mpMRI. The PI-RADS scoring system version 2.0 (PI-RADS v2) was used to describe the MRI findings. Univariate and multivariate analyses were performed to determine significant predictors of prostate cancer and clinically significant prostate cancer. In all, 288 patients were analysed. The median patient age, PSA level, prostate volume and PSA density were 69 years, 7.5 ng/mL, 28.7 mL, and 0.26 ng/mL/mL, respectively. The biopsy results were benign, clinically insignificant, and clinically significant prostate cancer in 129 (45%), 18 (6%) and 141 (49%) patients, respectively. The multivariate analysis revealed that PI-RADS v2 score and PSA density were independent predictors for prostate cancer and clinically significant prostate cancer. When PI-RADS v2 score and PSA density were combined, a PI-RADS v2 score of ≥4 and PSA density ≥0.15 ng/mL/mL, or PI-RADS v2 score of 3 and PSA density of ≥0.30 ng/mL/mL, was associated with the highest clinically significant prostate cancer detection rates (76-97%) on the first biopsy. Of the patients in this group with negative biopsy results, 22% were subsequently diagnosed as prostate cancer. In contrast, a PI

  17. Variability induced by the MR imager in dynamic contrast-enhanced imaging of the prostate.

    Science.gov (United States)

    Brunelle, S; Zemmour, C; Bratan, F; Mège-Lechevallier, F; Ruffion, A; Colombel, M; Crouzet, S; Sarran, A; Rouvière, O

    2018-04-01

    To evaluate the variability induced by the imager in discriminating high-grade (Gleason≥7) prostate cancers (HGC) using dynamic contrast-enhanced MRI. We retrospectively selected 3T MRIs with temporal resolution<10 seconds and comprising T1 mapping from a prospective radiologic-pathologic database of patients treated by prostatectomy. Ktrans, Kep, Ve and Vp were calculated for each lesion seen on MRI using the Weinmann arterial input function (AIF) and three patient-specific AIFs measured in the right and left iliac arteries in pixels in the center of the lumen (psAIF-ST) or manually selected by two independent readers (psAIF-R1 and psAIF-R2). A total of 43 patients (mean age, 63.6±4.9 [SD]; range: 48-72 years) with 100 lesions on MRI (55 HGC) were selected. MRIs were performed on imager A (22 patients, 49 lesions) or B (21 patients, 51 lesions) from two different manufacturers. Using the Weinmann AIF, Kep (P=0.005), Ve (P=0.04) and Vp (P=0.01) significantly discriminated HCG. After adjusting on tissue classes, the imager significantly influenced the values of Kep (P=0.049) and Ve (P=0.007). Using patient-specific AIFs, Vp with psAIF-ST (P=0.008) and psAIF-R2 (P=0.04), and Kep with psAIF-R1 (P=0.03) significantly discriminated HGC. After adjusting on tissue classes, types of patient-specific AIF and side of measurement, the imager significantly influenced the values of Ktrans (P=0.0002), Ve (P=0.0072) and Vp (P=0.0003). For all AIFs, the diagnostic value of pharmacokinetic parameters remained unchanged after adjustment on the imager, with stable odds ratios. The imager induced variability in the absolute values of pharmacokinetic parameters but did not change their diagnostic performance. Copyright © 2018 Société française de radiologie. Published by Elsevier Masson SAS. All rights reserved.

  18. Toxicity after intensity-modulated, image-guided radiotherapy for prostate cancer

    International Nuclear Information System (INIS)

    Flentje, Michael; Guckenberger, Matthias; Ok, Sami; Polat, Buelent; Sweeney, Reinhart A.

    2010-01-01

    Purpose: To evaluate toxicity after dose-escalated radiotherapy for prostate cancer using intensity-modulated treatment planning (IMRT) and image-guided treatment (IGRT) delivery. Patients and Methods: 100 patients were treated with simultaneous integrated boost (SIB) IMRT for prostate cancer: doses of 76.23 Gy and 60 Gy in 33 fractions were prescribed to the prostate and the seminal vesicles, respectively, for intermediate- and high-risk patients (n = 74). The total dose was 73.91 Gy in 32 fractions for low-risk patients and after transurethral resection of the prostate (n = 26). The pelvic lymphatics were treated with 46 Gy in 25 fractions in patients with high risk of lymph node metastases using an SIB to the prostate (n = 25). IGRT was practiced with cone-beam computed tomography. Acute and late gastrointestinal (GI) and genitourinary (GU) toxicity was evaluated prospectively (CTCAE v3.0). Results: Treatment was completed as planned by all patients. Acute GI and GU toxicity grade ≥ 2 was observed in 12% and 42% of the patients, respectively, with 4% suffering from GU toxicity grade 3. 6 weeks after treatment, the incidence of acute toxicity grade ≥ 2 had decreased to 12%. With a median follow-up of 26 months, late GI and GU toxicity grade ≥ 2 was seen in 1.5% and 7.7% of the patients at 24 months. Four patients developed late toxicity grade 3 (GI n = 1; GU n = 3). Presence of acute GI and GU toxicity was significantly associated with late GI (p = 0.0007) and GU toxicity (p = 0.006). Conclusion: High-dose radiotherapy for prostate cancer using IMRT and IGRT resulted in low rates of acute toxicity and preliminary results of late toxicity are promising. (orig.)

  19. Toxicity after intensity-modulated, image-guided radiotherapy for prostate cancer

    Energy Technology Data Exchange (ETDEWEB)

    Flentje, Michael [Dept. of Radiotherapy, Univ. Hospital Wuerzburg (Germany); Guckenberger, Matthias; Ok, Sami; Polat, Buelent; Sweeney, Reinhart A.

    2010-10-15

    Purpose: To evaluate toxicity after dose-escalated radiotherapy for prostate cancer using intensity-modulated treatment planning (IMRT) and image-guided treatment (IGRT) delivery. Patients and Methods: 100 patients were treated with simultaneous integrated boost (SIB) IMRT for prostate cancer: doses of 76.23 Gy and 60 Gy in 33 fractions were prescribed to the prostate and the seminal vesicles, respectively, for intermediate- and high-risk patients (n = 74). The total dose was 73.91 Gy in 32 fractions for low-risk patients and after transurethral resection of the prostate (n = 26). The pelvic lymphatics were treated with 46 Gy in 25 fractions in patients with high risk of lymph node metastases using an SIB to the prostate (n = 25). IGRT was practiced with cone-beam computed tomography. Acute and late gastrointestinal (GI) and genitourinary (GU) toxicity was evaluated prospectively (CTCAE v3.0). Results: Treatment was completed as planned by all patients. Acute GI and GU toxicity grade {>=} 2 was observed in 12% and 42% of the patients, respectively, with 4% suffering from GU toxicity grade 3. 6 weeks after treatment, the incidence of acute toxicity grade {>=} 2 had decreased to 12%. With a median follow-up of 26 months, late GI and GU toxicity grade {>=} 2 was seen in 1.5% and 7.7% of the patients at 24 months. Four patients developed late toxicity grade 3 (GI n = 1; GU n = 3). Presence of acute GI and GU toxicity was significantly associated with late GI (p = 0.0007) and GU toxicity (p = 0.006). Conclusion: High-dose radiotherapy for prostate cancer using IMRT and IGRT resulted in low rates of acute toxicity and preliminary results of late toxicity are promising. (orig.)

  20. Image-guided system versus manual marking for toric intraocular lens alignment in cataract surgery.

    Science.gov (United States)

    Webers, Valentijn S C; Bauer, Noel J C; Visser, Nienke; Berendschot, Tos T J M; van den Biggelaar, Frank J H M; Nuijts, Rudy M M A

    2017-06-01

    To compare the accuracy of toric intraocular lens (IOL) alignment using the Verion Image-Guided System versus a conventional manual ink-marking procedure. University Eye Clinic Maastricht, Maastricht, the Netherlands. Prospective randomized clinical trial. Eyes with regular corneal astigmatism of at least 1.25 diopters (D) that required cataract surgery and toric IOL implantation (Acrysof SN6AT3-T9) were randomly assigned to the image-guided group or the manual-marking group. The primary outcome was the alignment of the toric IOL based on preoperative images and images taken immediately after surgery. Secondary outcome measures were residual astigmatism, uncorrected distance visual acuity (UDVA), and complications. The study enrolled 36 eyes (24 patients). The mean toric IOL misalignment was significantly less in the image-guided group than in the manual group 1 hour (1.3 degrees ± 1.6 [SD] versus 2.8 ± 1.8 degrees; P = .02) and 3 months (1.7 ± 1.5 degrees versus 3.1 ± 2.1 degrees; P image-guided group and manual group, respectively (P > .05). The mean UDVA was 0.03 ± 0.10 logarithm of minimum angle of resolution (logMAR) and 0.04 ± 0.09 logMAR, respectively (both P > .05). No intraoperative complications occurred during any surgery. The IOL misalignment was significantly less with digital marking than with manual marking; this did not result in a better UDVA or lower residual refractive astigmatism. Copyright © 2017 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  1. Feasibility study using a Ni-Ti stent and electronic portal imaging to localize the prostate during radiotherapy.

    Science.gov (United States)

    Carl, Jesper; Lund, Bente; Larsen, Erik Hoejkjaer; Nielsen, Jane

    2006-02-01

    A new method for localization of the prostate during external beam radiotherapy is presented. The method is based on insertion of a thermo-expandable Ni-Ti stent. The stent is originally developed for treatment of bladder outlet obstruction caused by benign hyperplasia. The radiological properties of the stent are used for precise prostate localization during treatment using electronic portal images. Patients referred for intended curative radiotherapy and having a length of their prostatic urethra in the range from 25 to 65 mm were included. Pairs of isocentric orthogonal portal images were used to determine the 3D position at eight different treatment sessions for each patient. Fourteen patients were enrolled in the study. The data obtained demonstrated that the stent position was representative of the prostate location. The stent may also improve delineation of the prostate GTV, and prevent obstruction of bladder outlet during treatment. Precision in localization of the stent was less than 1 mm. Random errors in stent position were left-right 1.6 mm, cranial-caudal 2.2 mm and anterior-posterior 3.2 mm. In four of 14 patients a dislocation of the stent to the bladder occurred. Dislocation only occurred in patients with length of prostatic urethra less than 40 mm. A new method for radiological high precision localization of the prostate during radiotherapy is presented. The method is based on insertion of a standard Ni-Ti thermo-expandable stent, designed for treatment of benign prostate hyperplasia.

  2. BrachyView: Combining LDR seed positions with transrectal ultrasound imaging in a prostate gel phantom.

    Science.gov (United States)

    Alnaghy, S; Cutajar, D L; Bucci, J A; Enari, K; Safavi-Naeini, M; Favoino, M; Tartaglia, M; Carriero, F; Jakubek, J; Pospisil, S; Lerch, M; Rosenfeld, A B; Petasecca, M

    2017-02-01

    BrachyView is a novel in-body imaging system which aims to provide LDR brachytherapy seeds position reconstruction within the prostate in real-time. The first prototype is presented in this study: the probe consists of a gamma camera featuring three single cone pinhole collimators embedded in a tungsten tube, above three, high resolution pixelated detectors (Timepix). The prostate was imaged with a TRUS system using a sagittal crystal with a 2.5mm slice thickness. Eleven needles containing a total of thirty 0.508U 125 I seeds were implanted under ultrasound guidance. A CT scan was used to localise the seed positions, as well as provide a reference when performing the image co-registration between the BrachyView coordinate system and the TRUS coordinate system. An in-house visualisation software interface was developed to provide a quantitative 3D reconstructed prostate based on the TRUS images and co-registered with the LDR seeds in situ. A rigid body image registration was performed between the BrachyView and TRUS systems, with the BrachyView and CT-derived source locations compared. The reconstructed seed positions determined by the BrachyView probe showed a maximum discrepancy of 1.78mm, with 75% of the seeds reconstructed within 1mm of their nominal location. An accurate co-registration between the BrachyView and TRUS coordinate system was established. The BrachyView system has shown its ability to reconstruct all implanted LDR seeds within a tissue equivalent prostate gel phantom, providing both anatomical and seed position information in a single interface. Crown Copyright © 2017. Published by Elsevier Ltd. All rights reserved.

  3. Ultrasonic Nanobubbles Carrying Anti-PSMA Nanobody: Construction and Application in Prostate Cancer-Targeted Imaging.

    Directory of Open Access Journals (Sweden)

    Xiaozhou Fan

    Full Text Available To facilitate prostate cancer imaging using targeted molecules, we constructed ultrasonic nanobubbles coupled with specific anti-PSMA (prostate specific membrane antigen nanobodies, and evaluated their in vitro binding capacity and in vivo imaging efficacy. The "targeted" nanobubbles, which were constructed via a biotin-streptavidin system, had an average diameter of 487.60 ± 33.55 nm and carried the anti-PSMA nanobody as demonstrated by immunofluorescence. Microscopy revealed targeted binding of nanobubbles in vitro to PSMA-positive cells. Additionally, ultrasonography indicators of nanobubble imaging (including arrival time, peak time, peak intensity and enhanced duration were evaluated for the ultrasound imaging in three kinds of animal xenografts (LNCaP, C4-2 and MKN45, and showed that these four indicators of targeted nanobubbles exhibited significant differences from blank nanobubbles. Therefore, this study not only presents a novel approach to target prostate cancer ultrasonography, but also provides the basis and methods for constructing small-sized and high-efficient targeted ultrasound nanobubbles.

  4. Automatic classification of prostate stromal tissue in histological images using Haralick descriptors and Local Binary Patterns

    International Nuclear Information System (INIS)

    Oliveira, D L L; Batista, V R; Duarte, Y A S; Nascimento, M Z; Neves, L A; Godoy, M F; Jacomini, R S; Arruda, P F F; Neto, D S

    2014-01-01

    In this paper we presente a classification system that uses a combination of texture features from stromal regions: Haralick features and Local Binary Patterns (LBP) in wavelet domain. The system has five steps for classification of the tissues. First, the stromal regions were detected and extracted using segmentation techniques based on thresholding and RGB colour space. Second, the Wavelet decomposition was applied in the extracted regions to obtain the Wavelet coefficients. Third, the Haralick and LBP features were extracted from the coefficients. Fourth, relevant features were selected using the ANOVA statistical method. The classication (fifth step) was performed with Radial Basis Function (RBF) networks. The system was tested in 105 prostate images, which were divided into three groups of 35 images: normal, hyperplastic and cancerous. The system performance was evaluated using the area under the ROC curve and resulted in 0.98 for normal versus cancer, 0.95 for hyperplasia versus cancer and 0.96 for normal versus hyperplasia. Our results suggest that texture features can be used as discriminators for stromal tissues prostate images. Furthermore, the system was effective to classify prostate images, specially the hyperplastic class which is the most difficult type in diagnosis and prognosis

  5. Phase Retrieval Using a Genetic Algorithm on the Systematic Image-Based Optical Alignment Testbed

    Science.gov (United States)

    Taylor, Jaime R.

    2003-01-01

    NASA s Marshall Space Flight Center s Systematic Image-Based Optical Alignment (SIBOA) Testbed was developed to test phase retrieval algorithms and hardware techniques. Individuals working with the facility developed the idea of implementing phase retrieval by breaking the determination of the tip/tilt of each mirror apart from the piston motion (or translation) of each mirror. Presented in this report is an algorithm that determines the optimal phase correction associated only with the piston motion of the mirrors. A description of the Phase Retrieval problem is first presented. The Systematic Image-Based Optical Alignment (SIBOA) Testbeb is then described. A Discrete Fourier Transform (DFT) is necessary to transfer the incoming wavefront (or estimate of phase error) into the spatial frequency domain to compare it with the image. A method for reducing the DFT to seven scalar/matrix multiplications is presented. A genetic algorithm is then used to search for the phase error. The results of this new algorithm on a test problem are presented.

  6. Three-dimensional conformal external beam radiotherapy compared with permanent prostate implantation in low-risk prostate cancer based on endorectal magnetic resonance spectroscopy imaging and prostate-specific antigen level

    International Nuclear Information System (INIS)

    Pickett, Barby; Kurhanewicz, John; Pouliot, Jean; Weinberg, Vivian; Shinohara, Katsuto; Coakley, Fergus; Roach, Mack

    2006-01-01

    Purpose: To evaluate the metabolic response by comparing the time to resolution of spectroscopic abnormalities (TRSA) and the time to prostate-specific antigen level in low-risk prostate cancer patients after treatment with three-dimensional conformal external beam radiotherapy (3D-CRT) compared with permanent prostate implantation (PPI). Recent studies have suggested that the treatment of low-risk prostate cancer yields similar results for patients treated with 3D-CRT or PPI. Methods and Materials: A total of 50 patients, 25 in each group, who had been treated with 3D-CRT or PPI, had undergone endorectal magnetic resonance spectroscopy imaging before and/or at varying times after therapy. The 3D-CRT patients had received radiation doses of ≥72 Gy compared with 144 Gy for the PPI patients. The spectra from all usable voxels were examined for detectable levels of metabolic signal, and the percentages of atrophic and cancerous voxels were tabulated. Results: The median time to resolution of the spectroscopic abnormalities was 32.2 and 24.8 months and the time to the nadir prostate-specific antigen level was 52.4 and 38.0 months for the 3D-CRT and PPI patients, respectively. Of the 3D-CRT patients, 92% achieved negative endorectal magnetic resonance spectroscopy imaging findings, with 40% having complete metabolic atrophy. All 25 PPI patients had negative endorectal magnetic resonance spectroscopy imaging findings, with 60% achieving complete metabolic atrophy. Conclusion: The results of this study suggest that metabolic and biochemical responses of the prostate are more pronounced after PPI. Our results have not proved PPI is more effective at curing prostate cancer, but they have demonstrated that it may be more effective at destroying prostate metabolism

  7. Making a Back-Illuminated Imager with Back-Side Contact and Alignment Markers

    Science.gov (United States)

    Pain, Bedabrata

    2008-01-01

    A design modification and a fabrication process that implements the modification have been conceived to solve two problems encountered in the development of back-illuminated, back-sidethinned complementary metal oxide/ semiconductor (CMOS) image-detector integrated circuits. The two problems are (1) how to form metal electrical-contact pads on the back side that are electrically connected through the thickness in proper alignment with electrical contact points on the front side and (2) how to provide alignment keys on the back side to ensure proper registration of backside optical components (e.g., microlenses and/or color filters) with the front-side pixel pattern. The essence of the design modification is to add metal plugs that extend from the desired front-side locations through the thickness and protrude from the back side of the substrate. The plugs afford the required front-to-back electrical conduction, and the protrusions of the plugs serve as both the alignment keys and the bases upon which the back-side electrical-contact pads can be formed.

  8. Optical derotator alignment using image-processing algorithm for tracking laser vibrometer measurements of rotating objects.

    Science.gov (United States)

    Khalil, Hossam; Kim, Dongkyu; Jo, Youngjoon; Park, Kyihwan

    2017-06-01

    An optical component called a Dove prism is used to rotate the laser beam of a laser-scanning vibrometer (LSV). This is called a derotator and is used for measuring the vibration of rotating objects. The main advantage of a derotator is that it works independently from an LSV. However, this device requires very specific alignment, in which the axis of the Dove prism must coincide with the rotational axis of the object. If the derotator is misaligned with the rotating object, the results of the vibration measurement are imprecise, owing to the alteration of the laser beam on the surface of the rotating object. In this study, a method is proposed for aligning a derotator with a rotating object through an image-processing algorithm that obtains the trajectory of a landmark attached to the object. After the trajectory of the landmark is mathematically modeled, the amount of derotator misalignment with respect to the object is calculated. The accuracy of the proposed method for aligning the derotator with the rotating object is experimentally tested.

  9. Alignment and Imaging of the CS2 Dimer Inside Helium Nanodroplets

    Science.gov (United States)

    Pickering, James D.; Shepperson, Benjamin; Hübschmann, Bjarke A. K.; Thorning, Frederik; Stapelfeldt, Henrik

    2018-03-01

    The carbon disulphide (CS2) dimer is formed inside He nanodroplets and identified using fs laser-induced Coulomb explosion, by observing the CS2+ ion recoil velocity. It is then shown that a 160 ps moderately intense laser pulse can align the dimer in advantageous spatial orientations which allow us to determine the cross-shaped structure of the dimer by analysis of the correlations between the emission angles of the nascent CS2+ and S+ ions, following the explosion process. Our method will enable fs time-resolved structural imaging of weakly bound molecular complexes during conformational isomerization, including formation of exciplexes.

  10. Clinical assessment of CT-MRI image fusion software in localization of the prostate for 3D conformal radiation therapy

    International Nuclear Information System (INIS)

    Kagawa, Kazufumi; Lee, W. Robert; Schultheiss, Timothy E.; Hunt, Margie A.; Shaer, Andrew H.; Hanks, Gerald E.

    1996-01-01

    Purpose: To assess the utility of image fusion software and compare MRI prostate localization with CT localization in patients undergoing 3D conformal radiation therapy of prostate cancer. Materials and Methods: After a phantom study was performed to ensure the accuracy of image fusion procedure, 22 prostate cancer patients had CT and MRI studies before the start of radiotherapy. Immobilization casts used during radiation treatment were also used for both imaging studies. After the clinical target volume (CTV) (prostate or prostate + seminal vesicles) was defined on CT, slices from MRI study were reconstructed to match precisely the corresponding CT slices by identifying three common bony landmarks on each study. The CTV was separately defined on the matched MRI slices. Data related to the size and location of the prostate were compared between CT and MRI. The spatial relationship between the tip of urethrogram cone on CT and prostate apex seen on MRI was also scrutinized. Results: The phantom study showed the registration discrepancies between CT and MRI smaller than 1.0 mm in any pair of comparison. The patient study showed mean image registration error of 0.9 (± 0.6) mm. The average prostate volume was 63.0 (± 25.8) cm 3 and 50.9 (± 22.9) cm 3 determined by CT and MRI respectively (Fig. 1). The difference in prostate location with the two studies most commonly differed at the base and at the apex of the prostate (Fig. 2). On transverse MRI, the prostate apex was situated 7.1 (± 4.5) mm dorsal and 15.1 (± 4.0) mm cephalad to the tip of urethrogram cone (Fig. 3). Conclusions: CT-MRI image fusion study made it possible to compare the two modalities directly. MRI localization of the prostate is more accurate than CT, and indicates the distance from cone to apex is 15 mm. In view of excellent treatment results obtained with current CT localization of the prostate, still it may not be wise to reduce target volume to that demonstrated on MRI

  11. {sup 68}Ga-PSMA I and T PET/CT for assessment of prostate cancer: evaluation of image quality after forced diuresis and delayed imaging

    Energy Technology Data Exchange (ETDEWEB)

    Derlin, Thorsten; Weiberg, Desiree; Ross, Tobias L.; Bengel, Frank M. [Hannover Medical School, Department of Nuclear Medicine, Hannover (Germany); Klot, Christoph von [Hannover Medical School, Department of Urology and Urologic Oncology, Hannover (Germany); Wester, Hans-Juergen [Technische Universitaet Muenchen, Pharmaceutical Radiochemistry, Garching (Germany); Henkenberens, Christoph; Christiansen, Hans [Hannover Medical School, Department of Radiation Oncology, Hannover (Germany); Merseburger, Axel S. [University Hospital Schleswig-Holstein, Department of Urology, Campus Luebeck, Luebeck (Germany)

    2016-12-15

    Urinary radiotracer excretion of {sup 68}Ga-Labelled prostate-specific membrane antigen (PSMA) ligands may complicate the assessment of the prostate region and differentiation of lymph nodes from ureteral activity. The aim of this study was to assess the value of delayed imaging after forced diuresis. Sixty-six patients underwent {sup 68}Ga-PSMA I and T PET/CT for evaluation of prostate cancer at 60 min post-injection. In subgroups of patients, this was amended by delayed imaging after 180 min post-injection, preceded by furosemide and oral hydration early, at the time of tracer injection, or delayed, at 100 min post-injection. Urinary tracer activity within the bladder and focal ureteral activity was analyzed. After forced diuresis, linear and focal visualization of ureters was significantly reduced. After delayed furosemide, mean and peak bladder activity decreased (p < 0.001), and image quality of the prostate region improved on delayed images (p < 0.001). Early furosemide co-injection with tracer resulted in increased mean and peak bladder activity (p < 0.001) and in deteriorated image quality of the prostate region on delayed images (p = 0.008). Ga-PSMA I and T PET/CT delayed imaging after forced diuresis can improve the assessment of prostate region and pelvic lymph nodes by removing excreted tracer from the lower urinary tract. (orig.)

  12. Prostate-specific membrane antigen targeted protein contrast agents for molecular imaging of prostate cancer by MRI

    Science.gov (United States)

    Pu, Fan; Salarian, Mani; Xue, Shenghui; Qiao, Jingjuan; Feng, Jie; Tan, Shanshan; Patel, Anvi; Li, Xin; Mamouni, Kenza; Hekmatyar, Khan; Zou, Juan; Wu, Daqing; Yang, Jenny J.

    2016-06-01

    Prostate-specific membrane antigen (PSMA) is one of the most specific cell surface markers for prostate cancer diagnosis and targeted treatment. However, achieving molecular imaging using non-invasive MRI with high resolution has yet to be achieved due to the lack of contrast agents with significantly improved relaxivity for sensitivity, targeting capabilities and metal selectivity. We have previously reported our creation of a novel class of protein Gd3+ contrast agents, ProCA32, which displayed significantly improved relaxivity while exhibiting strong Gd3+ binding selectivity over physiological metal ions. In this study, we report our effort in further developing biomarker-targeted protein MRI contrast agents for molecular imaging of PSMA. Among three PSMA targeted contrast agents engineered with addition of different molecular recognition sequences, ProCA32.PSMA exhibits a binding affinity of 1.1 +/- 0.1 μM for PSMA while the metal binding affinity is maintained at 0.9 +/- 0.1 × 10-22 M. In addition, ProCA32.PSMA exhibits r1 of 27.6 mM-1 s-1 and r2 of 37.9 mM-1 s-1 per Gd (55.2 and 75.8 mM-1 s-1 per molecule r1 and r2, respectively) at 1.4 T. At 7 T, ProCA32.PSMA also has r2 of 94.0 mM-1 s-1 per Gd (188.0 mM-1 s-1 per molecule) and r1 of 18.6 mM-1 s-1 per Gd (37.2 mM-1 s-1 per molecule). This contrast capability enables the first MRI enhancement dependent on PSMA expression levels in tumor bearing mice using both T1 and T2-weighted MRI at 7 T. Further development of these PSMA-targeted contrast agents are expected to be used for the precision imaging of prostate cancer at an early stage and to monitor disease progression and staging, as well as determine the effect of therapeutic treatment by non-invasive evaluation of the PSMA level using MRI.Prostate-specific membrane antigen (PSMA) is one of the most specific cell surface markers for prostate cancer diagnosis and targeted treatment. However, achieving molecular imaging using non-invasive MRI with high

  13. Cone beam computed tomography: An accurate imaging technique in comparison with orthogonal portal imaging in intensity-modulated radiotherapy for prostate cancer

    Directory of Open Access Journals (Sweden)

    Om Prakash Gurjar

    2016-03-01

    Full Text Available Purpose: Various factors cause geometric uncertainties during prostate radiotherapy, including interfractional and intrafractional patient motions, organ motion, and daily setup errors. This may lead to increased normal tissue complications when a high dose to the prostate is administered. More-accurate treatment delivery is possible with daily imaging and localization of the prostate. This study aims to measure the shift of the prostate by using kilovoltage (kV cone beam computed tomography (CBCT after position verification by kV orthogonal portal imaging (OPI.Methods: Position verification in 10 patients with prostate cancer was performed by using OPI followed by CBCT before treatment delivery in 25 sessions per patient. In each session, OPI was performed by using an on-board imaging (OBI system and pelvic bone-to-pelvic bone matching was performed. After applying the noted shift by using OPI, CBCT was performed by using the OBI system and prostate-to-prostate matching was performed. The isocenter shifts along all three translational directions in both techniques were combined into a three-dimensional (3-D iso-displacement vector (IDV.Results: The mean (SD IDV (in centimeters calculated during the 250 imaging sessions was 0.931 (0.598, median 0.825 for OPI and 0.515 (336, median 0.43 for CBCT, p-value was less than 0.0001 which shows extremely statistical significant difference.Conclusion: Even after bone-to-bone matching by using OPI, a significant shift in prostate was observed on CBCT. This study concludes that imaging with CBCT provides a more accurate prostate localization than the OPI technique. Hence, CBCT should be chosen as the preferred imaging technique.

  14. Bacterial prostatitis.

    Science.gov (United States)

    Gill, Bradley C; Shoskes, Daniel A

    2016-02-01

    The review provides the infectious disease community with a urologic perspective on bacterial prostatitis. Specifically, the article briefly reviews the categorization of prostatitis by type and provides a distillation of new findings published on bacterial prostatitis over the past year. It also highlights key points from the established literature. Cross-sectional prostate imaging is becoming more common and may lead to more incidental diagnoses of acute bacterial prostatitis. As drug resistance remains problematic in this condition, the reemergence of older antibiotics such as fosfomycin, has proven beneficial. With regard to chronic bacterial prostatitis, no clear clinical risk factors emerged in a large epidemiological study. However, bacterial biofilm formation has been associated with more severe cases. Surgery has a limited role in bacterial prostatitis and should be reserved for draining of a prostatic abscess or the removal of infected prostatic stones. Prostatitis remains a common and bothersome clinical condition. Antibiotic therapy remains the basis of treatment for both acute and chronic bacterial prostatitis. Further research into improving prostatitis treatment is indicated.

  15. Echo-Planar Imaging-Based, J-Resolved Spectroscopic Imaging for Improved Metabolite Detection in Prostate Cancer

    Science.gov (United States)

    2016-12-01

    post-process the multi-dimensional MRS data from different prostate pathologies . Scope: Improved cancer detection (specificity) in differentiating...MATERIALS AND METHODS Patients Between March 2012 and May 2013, twenty-two patients with PCa with a mean age of 63.8 years (range, 46–79 years), who...tumor voxels, which was confirmed by the pathology report. After reconstruction, the EP-JRESI data were overlaid onto MRI images. MRI and MRSI A body

  16. Rectal dose variation during the course of image-guided radiation therapy of prostate cancer

    International Nuclear Information System (INIS)

    Chen Lili; Paskalev, Kamen; Xu Xiu; Zhu, Jennifer; Wang Lu; Price, Robert A.; Hu Wei; Feigenberg, Steven J.; Horwitz, Eric M.; Pollack, Alan; Charlie Ma, C.M.

    2010-01-01

    Background and purpose: To investigate the change in rectal dose during the treatment course for intensity-modulated radiotherapy (IMRT) of prostate cancer with image-guidance. Materials and methods: Twenty prostate cancer patients were recruited for this retrospective study. All patients have been treated with IMRT. For each patient, MR and CT images were fused for target and critical structure delineation. IMRT treatment planning was performed on the simulation CT images. Inter-fractional motion during the course of treatment was corrected using a CT-on-rails system. The rectum was outlined on both the original treatment plan and the subsequent daily CT images from the CT-on-rails by the same investigator. Dose distributions on these daily CT images were recalculated with the isocenter shifts relative to the simulation CT images using the leaf sequences/MUs based on the original treatment plan. The rectal doses from the subsequent daily CTs were compared with the original doses planned on the simulation CT using our clinical acceptance criteria. Results: Based on 20 patients with 139 daily CT sets, 28% of the subsequent treatment dose distributions did not meet our criterion of V 40 65 < 17%. The inter-fractional rectal volume variation is significant for some patients. Conclusions: Due to the large inter-fractional variation of the rectal volume, it is more favorable to plan prostate IMRT based on an empty rectum and deliver treatment to patients with an empty rectum. Over 70% of actual treatments showed better rectal doses than our clinical acceptance criteria. A significant fraction (27%) of the actual treatments would benefit from adaptive image-guided radiotherapy based on daily CT images.

  17. PET imaging of urokinase-type plasminogen activator receptor (uPAR) in prostate cancer

    DEFF Research Database (Denmark)

    Skovgaard, Dorthe; Persson, Morten; Kjaer, Andreas

    2016-01-01

    Overexpression of urokinase-type plasminogen activator receptors (uPAR) represents an important biomarker for aggressiveness in most common malignant diseases, including prostate cancer (PC). Accordingly, uPAR expression either assessed directly in malignant PC tissue or assessed directly in plasma...... and prognostic imaging method. In this review, we will focus on the recent development of uPAR PET and the relevance within prostate cancer imaging. Novel antibody and small-molecule radiotracers-targeting uPAR, including a series of uPAR-targeting PET ligands, based on the high affinity peptide ligand AE105......, have been synthesized and tested in vitro and in vivo in preclinical murine xenograft models and, recently, in a first-ever clinical uPAR PET study in cancer patients, including patients with PC. In this phase I study, a high and specific uptake of the tracer 64Cu-DOTA-AE105 was found in both primary...

  18. Inter-fractional Target Displacement in the Prostate Image-Guided Radiotherapy using Cone Beam Computed Tomography

    International Nuclear Information System (INIS)

    Dong, Kap Sang; Back, Chang Wook; Jeong, Yun Jeong; Bae, Jae Beom; Choi, Young Eun; Sung, Ki Hoon

    2016-01-01

    To quantify the inter-fractional variation in prostate displacement and their dosimetric effects for prostate cancer treatment. A total of 176 daily cone-beam CT (CBCT) sets acquired for 6 prostate cancer patients treated with volumetric-modulated arc therapy (VMAT) were retrospectively reviewed. For each patient, the planning CT (pCT) was registered to each daily CBCT by aligning the bony anatomy. The prostate, rectum, and bladder were delineated on daily CBCT, and the contours of these organs in the pCT were copied to the daily CBCT. The concordance of prostate displacement, deformation, and size variation between pCT and daily CBCT was evaluated using the Dice similarity coefficient (DSC). The mean volume of prostate was 37.2 cm3 in the initial pCT, and the variation was around ±5% during the entire course of treatment for all patients. The mean DSC was 89.9%, ranging from 70% to 100% for prostate displacement. Although the volume change of bladder and rectum per treatment fraction did not show any correlation with the value of DSC (r=-0.084, p=0.268 and r=-0.162, p=0.032, respectively), a decrease in the DSC value was observed with increasing volume change of the bladder and rectum (r=-0.230,p=0.049 and r=-0.240,p=0.020, respectively). Consistency of the volume of the bladder and rectum cannot guarantee the accuracy of the treatment. Our results suggest that patient setup with the registration between the pCT and daily CBCT should be considered aligning soft tissue

  19. Inter-fractional Target Displacement in the Prostate Image-Guided Radiotherapy using Cone Beam Computed Tomography

    Energy Technology Data Exchange (ETDEWEB)

    Dong, Kap Sang; Back, Chang Wook; Jeong, Yun Jeong; Bae, Jae Beom; Choi, Young Eun; Sung, Ki Hoon [Dept. of Radiation Oncology, Gachon University Gil Medical Center, Incheon (Korea, Republic of)

    2016-12-15

    To quantify the inter-fractional variation in prostate displacement and their dosimetric effects for prostate cancer treatment. A total of 176 daily cone-beam CT (CBCT) sets acquired for 6 prostate cancer patients treated with volumetric-modulated arc therapy (VMAT) were retrospectively reviewed. For each patient, the planning CT (pCT) was registered to each daily CBCT by aligning the bony anatomy. The prostate, rectum, and bladder were delineated on daily CBCT, and the contours of these organs in the pCT were copied to the daily CBCT. The concordance of prostate displacement, deformation, and size variation between pCT and daily CBCT was evaluated using the Dice similarity coefficient (DSC). The mean volume of prostate was 37.2 cm3 in the initial pCT, and the variation was around ±5% during the entire course of treatment for all patients. The mean DSC was 89.9%, ranging from 70% to 100% for prostate displacement. Although the volume change of bladder and rectum per treatment fraction did not show any correlation with the value of DSC (r=-0.084, p=0.268 and r=-0.162, p=0.032, respectively), a decrease in the DSC value was observed with increasing volume change of the bladder and rectum (r=-0.230,p=0.049 and r=-0.240,p=0.020, respectively). Consistency of the volume of the bladder and rectum cannot guarantee the accuracy of the treatment. Our results suggest that patient setup with the registration between the pCT and daily CBCT should be considered aligning soft tissue.

  20. Relationship of Imaging Frequency and Planning Margin to Account for Intrafraction Prostate Motion: Analysis Based on Real-Time Monitoring Data

    International Nuclear Information System (INIS)

    Curtis, William; Khan, Mohammad; Magnelli, Anthony; Stephans, Kevin; Tendulkar, Rahul; Xia, Ping

    2013-01-01

    Purpose: Correction for intrafraction prostate motion becomes important for hypofraction treatment of prostate cancer. The purpose of this study was to estimate an ideal planning margin to account for intrafraction prostate motion as a function of imaging and repositioning frequency in the absence of continuous prostate motion monitoring. Methods and Materials: For 31 patients receiving intensity modulated radiation therapy treatment, prostate positions sampled at 10 Hz during treatment using the Calypso system were analyzed. Using these data, we simulated multiple, less frequent imaging protocols, including intervals of every 10, 15, 20, 30, 45, 60, 90, 120, 180, and 240 seconds. For each imaging protocol, the prostate displacement at the imaging time was corrected by subtracting prostate shifts from the subsequent displacements in that fraction. Furthermore, we conducted a principal component analysis to quantify the direction of prostate motion. Results: Averaging histograms of every 240 and 60 seconds for all patients, vector displacements of the prostate were, respectively, within 3 and 2 mm for 95% of the treatment time. A vector margin of 1 mm achieved 91.2% coverage of the prostate with 30 second imaging. The principal component analysis for all fractions showed the largest variance in prostate position in the midsagittal plane at 54° from the anterior direction, indicating that anterosuperior to inferoposterior is the direction of greatest motion. The smallest prostate motion is in the left-right direction. Conclusions: The magnitudes of intrafraction prostate motion along the superior-inferior and anterior-posterior directions are comparable, and the smallest motion is in the left-right direction. In the absence of continuous prostate motion monitoring, and under ideal circumstances, 1-, 2-, and 3-mm vector planning margins require a respective imaging frequency of every 15, 60, and 240 to account for intrafraction prostate motion while achieving

  1. Tensor voting for image correction by global and local intensity alignment.

    Science.gov (United States)

    Jia, Jiaya; Tang, Chi-Keung

    2005-01-01

    This paper presents a voting method to perform image correction by global and local intensity alignment. The key to our modeless approach is the estimation of global and local replacement functions by reducing the complex estimation problem to the robust 2D tensor voting in the corresponding voting spaces. No complicated model for replacement function (curve) is assumed. Subject to the monotonic constraint only, we vote for an optimal replacement function by propagating the curve smoothness constraint using a dense tensor field. Our method effectively infers missing curve segments and rejects image outliers. Applications using our tensor voting approach are proposed and described. The first application consists of image mosaicking of static scenes, where the voted replacement functions are used in our iterative registration algorithm for computing the best warping matrix. In the presence of occlusion, our replacement function can be employed to construct a visually acceptable mosaic by detecting occlusion which has large and piecewise constant color. Furthermore, by the simultaneous consideration of color matches and spatial constraints in the voting space, we perform image intensity compensation and high contrast image correction using our voting framework, when only two defective input images are given.

  2. On the image formation in x-ray radiography using aligned carbon nanofibers

    Energy Technology Data Exchange (ETDEWEB)

    Okuyama, F., E-mail: okuya@mui.biglobe.ne.jp

    2017-04-11

    Evidence is presented that field electrons emitted from vertically-aligned carbon nanofibers (CNFs) yield clearer x-ray images than do thermionic electrons, under the identical electron-optical condition. Specifically, the same sample, an LSI circuit, mounted on the same x-ray chamber could be imaged far more sharply with a CNF emitter than with a thermionic one. It is hypothesized that electrons discharged from CNF tips hit the target to form “discrete focal points” thereon, thereby generating multiple x-ray beams that interplay to form a brilliant, sharply-delineated x-ray image. This hypothesis may stimulate open discussion on how to define the “focal point” for the x-ray imaging using nano-structured electron sources. Also, the improved resolution attained with CNFs might indicate that the heat generation originating in electron-target interactions is not so serious in the present field-emission mode. - Highlights: • Field-emission (FE) x-ray radiography (XR) is based on nanotechnology. • FE-XR surpasses thermionic XR in image resolution and brilliance. • Highly-resolved FE-XR images are due possibly to a discrete array of x-ray spots. • This hypothesis stimulates open discussion on how to define the focal-point in FE-XR.

  3. On the image formation in x-ray radiography using aligned carbon nanofibers

    International Nuclear Information System (INIS)

    Okuyama, F.

    2017-01-01

    Evidence is presented that field electrons emitted from vertically-aligned carbon nanofibers (CNFs) yield clearer x-ray images than do thermionic electrons, under the identical electron-optical condition. Specifically, the same sample, an LSI circuit, mounted on the same x-ray chamber could be imaged far more sharply with a CNF emitter than with a thermionic one. It is hypothesized that electrons discharged from CNF tips hit the target to form “discrete focal points” thereon, thereby generating multiple x-ray beams that interplay to form a brilliant, sharply-delineated x-ray image. This hypothesis may stimulate open discussion on how to define the “focal point” for the x-ray imaging using nano-structured electron sources. Also, the improved resolution attained with CNFs might indicate that the heat generation originating in electron-target interactions is not so serious in the present field-emission mode. - Highlights: • Field-emission (FE) x-ray radiography (XR) is based on nanotechnology. • FE-XR surpasses thermionic XR in image resolution and brilliance. • Highly-resolved FE-XR images are due possibly to a discrete array of x-ray spots. • This hypothesis stimulates open discussion on how to define the focal-point in FE-XR.

  4. Image-guided adaptive radiation therapy (IGART): Radiobiological and dose escalation considerations for localized carcinoma of the prostate

    International Nuclear Information System (INIS)

    Song, William; Schaly, Bryan; Bauman, Glenn; Battista, Jerry; Van Dyk, Jake

    2005-01-01

    The goal of this work was to evaluate the efficacy of various image-guided adaptive radiation therapy (IGART) techniques to deliver and escalate dose to the prostate in the presence of geometric uncertainties. Five prostate patients with 15-16 treatment CT studies each were retrospectively analyzed. All patients were planned with an 18 MV, six-field conformal technique with a 10 mm margin size and an initial prescription of 70 Gy in 35 fractions. The adaptive strategy employed in this work for patient-specific dose escalation was to increase the prescription dose in 2 Gy-per-fraction increments until the rectum normal tissue complication probability (NTCP) reached a level equal to that of the nominal plan NTCP (i.e., iso-NTCP dose escalation). The various target localization techniques simulated were: (1) daily laser-guided alignment to skin tattoo marks that represents treatment without image-guidance, (2) alignment to bony landmarks with daily portal images, and (3) alignment to the clinical target volume (CTV) with daily CT images. Techniques (1) and (3) were resimulated with a reduced margin size of 5 mm to investigate further dose escalation. When delivering the original clinical prescription dose of 70 Gy in 35 fractions, the 'CTV registration' technique yielded the highest tumor control probability (TCP) most frequently, followed by the 'bone registration' and 'tattoo registration' techniques. However, the differences in TCP among the three techniques were minor when the margin size was 10 mm (≤1.1%). Reducing the margin size to 5 mm significantly degraded the TCP values of the 'tattoo registration' technique in two of the five patients, where a large difference was found compared to the other techniques (≤11.8%). The 'CTV registration' technique, however, did maintain similar TCP values compared to their 10 mm margin counterpart. In terms of normal tissue sparing, the technique producing the lowest NTCP varied from patient to patient. Reducing the

  5. Proton therapy for prostate cancer treatment employing online image guidance and an action level threshold.

    Science.gov (United States)

    Vargas, Carlos; Falchook, Aaron; Indelicato, Daniel; Yeung, Anamaria; Henderson, Randall; Olivier, Kenneth; Keole, Sameer; Williams, Christopher; Li, Zuofeng; Palta, Jatinder

    2009-04-01

    The ability to determine the accuracy of the final prostate position within a determined action level threshold for image-guided proton therapy is unclear. Three thousand one hundred ten images for 20 consecutive patients treated in 1 of our 3 proton prostate protocols from February to May of 2007 were analyzed. Daily kV images and patient repositioning were performed employing an action-level threshold (ALT) of > or = 2.5 mm for each beam. Isocentric orthogonal x-rays were obtained, and prostate position was defined via 3 gold markers for each patient in the 3 axes. To achieve and confirm our action level threshold, an average of 2 x-rays sets (median 2; range, 0-4) was taken daily for each patient. Based on our ALT, we made no corrections in 8.7% (range, 0%-54%), 1 correction in 82% (41%-98%), and 2 to 3 corrections in 9% (0-27%). No patient needed 4 or more corrections. All patients were treated with a confirmed error of < 2.5 mm for every beam delivered. After all corrections, the mean and standard deviations were: anterior-posterior (z): 0.003 +/- 0.094 cm; superior-inferior (y): 0.028 +/- 0.073 cm; and right-left (x) -0.013 +/- 0.08 cm. It is feasible to limit all final prostate positions to less than 2.5 mm employing an action level image-guided radiation therapy (IGRT) process. The residual errors after corrections were very small.

  6. Time-Resolved Spectroscopy and Near Infrared Imaging for Prostate Cancer Detection: Receptor-targeted and Native Biomarker

    Science.gov (United States)

    Pu, Yang

    Optical spectroscopy and imaging using near-infrared (NIR) light provides powerful tools for non-invasive detection of cancer in tissue. Optical techniques are capable of quantitative reconstructions maps of tissue absorption and scattering properties, thus can map in vivo the differences in the content of certain marker chromophores and/or fluorophores in normal and cancerous tissues (for example: water, tryptophan, collagen and NADH contents). Potential clinical applications of optical spectroscopy and imaging include functional tumor detection and photothermal therapeutics. Optical spectroscopy and imaging apply contrasts from intrinsic tissue chromophores such as water, collagen and NADH, and extrinsic optical contrast agents such as Indocyanine Green (ICG) to distinguish disease tissue from the normal one. Fluorescence spectroscopy and imaging also gives high sensitivity and specificity for biomedical diagnosis. Recent developments on specific-targeting fluorophores such as small receptor-targeted dye-peptide conjugate contrast agent offer high contrast between normal and cancerous tissues hence provide promising future for early tumour detection. This thesis focus on a study to distinguish the cancerous prostate tissue from the normal prostate tissues with enhancement of specific receptor-targeted prostate cancer contrast agents using optical spectroscopy and imaging techniques. The scattering and absorption coefficients, and anisotropy factor of cancerous and normal prostate tissues were investigated first as the basis for the biomedical diagnostic and optical imaging. Understanding the receptors over-expressed prostate cancer cells and molecular target mechanism of ligand, two small ICG-derivative dye-peptides, namely Cypate-Bombesin Peptide Analogue Conjugate (Cybesin) and Cypate-Octreotate Peptide Conjugate (Cytate), were applied to study their clinical potential for human prostate cancer detection. In this work, the steady-state and time

  7. Prostate Ultrasound

    Medline Plus

    Full Text Available ... receiver coil. top of page Additional Information and Resources RTAnswers.org Radiation Therapy for Prostate Cancer top ... here Images × Image Gallery Radiologist and patient consultation. View full size with caption Related Articles and Media ...

  8. Image-Guided Hypofractionated Radiotherapy in Low-Risk Prostate Cancer Patients

    Directory of Open Access Journals (Sweden)

    Maurizio Valeriani

    2014-01-01

    Full Text Available Aim. To evaluate efficacy and toxicity of image-guided hypofractionated radiotherapy (HFRT in the treatment of low-risk prostate cancer. Outcomes and toxicities of this series of patients were compared to another group of 32 low-risk patients treated with conventional fractionation (CFRT. Methods. Fifty-nine patients with low-risk prostate cancer were analysed. Total dose for the prostate and proximal seminal vesicles was 60 Gy delivered in 20 fractions. Results. The median follow-up was 30 months. The actuarial 4-year overall survival, biochemical free survival, and disease specific survival were 100%, 97.4%, and 97.4%, respectively. Acute grade 1-2 gastrointestinal (GI and genitourinary (GU toxicity rates were 11.9% and 40.7%, respectively. Grade 1 GI and GU late toxicity rates were 8.5% and 13.6%, respectively. No grade ≥2 late toxicities were recorded. Acute grade 2-3 GU toxicity resulted significantly lower (P=0.04 in HFRT group compared to the CFRT group. The cumulative 4-year incidence of grade 1-2 GU toxicity was significantly higher (P<0.001 for HFRT patients. Conclusions. Our study demonstrated that hypofractionated regimen provided excellent biochemical control in favorable risk prostate cancer patients. The incidence of GI and GU toxicity was low. However, HFRT presented higher cumulative incidence of low-grade late GU toxicity than CFRT.

  9. Value of diffusion-Weighted imaging in evaluating the cellularity density of prostate cancer

    International Nuclear Information System (INIS)

    Liu Jingang; Wang Xizhen; Wang Bin; Niu Qingliang; Liu Qiang

    2008-01-01

    Objective: To study the cellularity density of prostate cancer (PCa) with diffusion-weighted imaging (DWI) and apparent diffusion coefficient (ADC). Methods: 38 patients with histologically proven prostate cancer (PCa) underwent DWI with a 1.5 T MR scanner using a pelvic phased array multi-coil. The ADC values of PCa, benign prostatic hyperplasia (BPH), and peripheral zone (PZ) were calculated. The cellularity density of PCa was recorded according to hematoxylin and eosin (HE) staining. The relationship between ADC value and cellularity density of PCa was analyzed with Pearson correlation coefficient. Results: The ADC values of PCa, BPH, and PZ were (49.32±12.68)×10 -5 mm 2 /s, (86.73±26.75)×10 -5 mm 2 /s and (126.25±27.21)×10 -5 mm 2 /s, respectively. The ADC value of PCa was significantly lower than that of BPH and PZ (P<005). The cellularity density of PCa was 12.9%. The ADC value reversely related to the cellularity density of prostate cancer (r=-0.646, P<005). Conclusion: The ADC value can reflect the cellularity density of PCa. (authors)

  10. Multiple Time-Point 68Ga-PSMA I&T PET/CT for Characterization of Primary Prostate Cancer: Value of Early Dynamic and Delayed Imaging.

    Science.gov (United States)

    Schmuck, Sebastian; Mamach, Martin; Wilke, Florian; von Klot, Christoph A; Henkenberens, Christoph; Thackeray, James T; Sohns, Jan M; Geworski, Lilli; Ross, Tobias L; Wester, Hans-Juergen; Christiansen, Hans; Bengel, Frank M; Derlin, Thorsten

    2017-06-01

    The aims of this study were to gain mechanistic insights into prostate cancer biology using dynamic imaging and to evaluate the usefulness of multiple time-point Ga-prostate-specific membrane antigen (PSMA) I&T PET/CT for the assessment of primary prostate cancer before prostatectomy. Twenty patients with prostate cancer underwent Ga-PSMA I&T PET/CT before prostatectomy. The PET protocol consisted of early dynamic pelvic imaging, followed by static scans at 60 and 180 minutes postinjection (p.i.). SUVs, time-activity curves, quantitative analysis based on a 2-tissue compartment model, Patlak analysis, histopathology, and Gleason grading were compared between prostate cancer and benign prostate gland. Primary tumors were identified on both early dynamic and delayed imaging in 95% of patients. Tracer uptake was significantly higher in prostate cancer compared with benign prostate tissue at any time point (P ≤ 0.0003) and increased over time. Consequently, the tumor-to-nontumor ratio within the prostate gland improved over time (2.8 at 10 minutes vs 17.1 at 180 minutes p.i.). Tracer uptake at both 60 and 180 minutes p.i. was significantly higher in patients with higher Gleason scores (P dynamic and static delayed Ga-PSMA ligand PET images. The tumor-to-nontumor ratio in the prostate gland improves over time, supporting a role of delayed imaging for optimal visualization of prostate cancer.

  11. The use of atlas registration and graph cuts for prostate segmentation in magnetic resonance images

    Energy Technology Data Exchange (ETDEWEB)

    Korsager, Anne Sofie, E-mail: asko@hst.aau.dk; Østergaard, Lasse Riis [Department of Health Science and Technology, Aalborg University, Aalborg 9220 (Denmark); Fortunati, Valerio; Lijn, Fedde van der; Niessen, Wiro; Walsum, Theo van [Biomedical Imaging Group of Rotterdam, Department of Medical Informatics and Radiology, Erasmus MC, Rotterdam 3015 GE Rotterdam (Netherlands); Carl, Jesper [Department of Medical Physics, Oncology, Aalborg University Hospital, Aalborg 9220 (Denmark)

    2015-04-15

    Purpose: An automatic method for 3D prostate segmentation in magnetic resonance (MR) images is presented for planning image-guided radiotherapy treatment of prostate cancer. Methods: A spatial prior based on intersubject atlas registration is combined with organ-specific intensity information in a graph cut segmentation framework. The segmentation is tested on 67 axial T{sub 2}-weighted MR images in a leave-one-out cross validation experiment and compared with both manual reference segmentations and with multiatlas-based segmentations using majority voting atlas fusion. The impact of atlas selection is investigated in both the traditional atlas-based segmentation and the new graph cut method that combines atlas and intensity information in order to improve the segmentation accuracy. Best results were achieved using the method that combines intensity information, shape information, and atlas selection in the graph cut framework. Results: A mean Dice similarity coefficient (DSC) of 0.88 and a mean surface distance (MSD) of 1.45 mm with respect to the manual delineation were achieved. Conclusions: This approaches the interobserver DSC of 0.90 and interobserver MSD 0f 1.15 mm and is comparable to other studies performing prostate segmentation in MR.

  12. Snow and Water Imaging Spectrometer (SWIS): first alignment and characterization results

    Science.gov (United States)

    Bender, Holly A.; Mouroulis, Pantazis; Haag, Justin; Smith, Christopher D.; Van Gorp, Byron E.

    2017-09-01

    The Snow and Water Imaging Spectrometer (SWIS) is a fast, high-uniformity, low-polarization sensitivity imaging spectrometer and telescope system designed for integration on a 6U CubeSat platform. Operating in the 350-1700 nm spectral region with 5.7 nm sampling, SWIS is capable of simultaneously addressing the demanding needs of coastal ocean science and snow and ice monitoring. New key technologies that facilitate the development of this instrument include a linear variable anti-reflection (LVAR) detector coating for stray light management, and a single drive on-board calibration mechanism utilizing a transmissive diffuser for solar calibration. We provide an overview of the SWIS instrument design and potential science applications and describe the instrument assembly and alignment, supported by laboratory measurements.

  13. Genetic Algorithm Phase Retrieval for the Systematic Image-Based Optical Alignment Testbed

    Science.gov (United States)

    Taylor, Jaime; Rakoczy, John; Steincamp, James

    2003-01-01

    Phase retrieval requires calculation of the real-valued phase of the pupil fimction from the image intensity distribution and characteristics of an optical system. Genetic 'algorithms were used to solve two one-dimensional phase retrieval problem. A GA successfully estimated the coefficients of a polynomial expansion of the phase when the number of coefficients was correctly specified. A GA also successfully estimated the multiple p h e s of a segmented optical system analogous to the seven-mirror Systematic Image-Based Optical Alignment (SIBOA) testbed located at NASA s Marshall Space Flight Center. The SIBOA testbed was developed to investigate phase retrieval techniques. Tiphilt and piston motions of the mirrors accomplish phase corrections. A constant phase over each mirror can be achieved by an independent tip/tilt correction: the phase Conection term can then be factored out of the Discrete Fourier Tranform (DFT), greatly reducing computations.

  14. Automated alignment system for optical wireless communication systems using image recognition.

    Science.gov (United States)

    Brandl, Paul; Weiss, Alexander; Zimmermann, Horst

    2014-07-01

    In this Letter, we describe the realization of a tracked line-of-sight optical wireless communication system for indoor data distribution. We built a laser-based transmitter with adaptive focus and ray steering by a microelectromechanical systems mirror. To execute the alignment procedure, we used a CMOS image sensor at the transmitter side and developed an algorithm for image recognition to localize the receiver's position. The receiver is based on a self-developed optoelectronic integrated chip with low requirements on the receiver optics to make the system economically attractive. With this system, we were able to set up the communication link automatically without any back channel and to perform error-free (bit error rate <10⁻⁹) data transmission over a distance of 3.5 m with a data rate of 3 Gbit/s.

  15. Bidirectional composition on lie groups for gradient-based image alignment.

    Science.gov (United States)

    Mégret, Rémi; Authesserre, Jean-Baptiste; Berthoumieu, Yannick

    2010-09-01

    In this paper, a new formulation based on bidirectional composition on Lie groups (BCL) for parametric gradient-based image alignment is presented. Contrary to the conventional approaches, the BCL method takes advantage of the gradients of both template and current image without combining them a priori. Based on this bidirectional formulation, two methods are proposed and their relationship with state-of-the-art gradient based approaches is fully discussed. The first one, i.e., the BCL method, relies on the compositional framework to provide the minimization of the compensated error with respect to an augmented parameter vector. The second one, the projected BCL (PBCL), corresponds to a close approximation of the BCL approach. A comparative study is carried out dealing with computational complexity, convergence rate and frequence of convergence. Numerical experiments using a conventional benchmark show the performance improvement especially for asymmetric levels of noise, which is also discussed from a theoretical point of view.

  16. A multiparametric magnetic resonance imaging-based risk model to determine the risk of significant prostate cancer prior to biopsy.

    Science.gov (United States)

    van Leeuwen, Pim J; Hayen, Andrew; Thompson, James E; Moses, Daniel; Shnier, Ron; Böhm, Maret; Abuodha, Magdaline; Haynes, Anne-Maree; Ting, Francis; Barentsz, Jelle; Roobol, Monique; Vass, Justin; Rasiah, Krishan; Delprado, Warick; Stricker, Phillip D

    2017-12-01

    To develop and externally validate a predictive model for detection of significant prostate cancer. Development of the model was based on a prospective cohort including 393 men who underwent multiparametric magnetic resonance imaging (mpMRI) before biopsy. External validity of the model was then examined retrospectively in 198 men from a separate institution whom underwent mpMRI followed by biopsy for abnormal prostate-specific antigen (PSA) level or digital rectal examination (DRE). A model was developed with age, PSA level, DRE, prostate volume, previous biopsy, and Prostate Imaging Reporting and Data System (PIRADS) score, as predictors for significant prostate cancer (Gleason 7 with >5% grade 4, ≥20% cores positive or ≥7 mm of cancer in any core). Probability was studied via logistic regression. Discriminatory performance was quantified by concordance statistics and internally validated with bootstrap resampling. In all, 393 men had complete data and 149 (37.9%) had significant prostate cancer. While the variable model had good accuracy in predicting significant prostate cancer, area under the curve (AUC) of 0.80, the advanced model (incorporating mpMRI) had a significantly higher AUC of 0.88 (P prostate cancer. Individualised risk assessment of significant prostate cancer using a predictive model that incorporates mpMRI PIRADS score and clinical data allows a considerable reduction in unnecessary biopsies and reduction of the risk of over-detection of insignificant prostate cancer at the cost of a very small increase in the number of significant cancers missed. © 2017 The Authors BJU International © 2017 BJU International Published by John Wiley & Sons Ltd.

  17. In vivo cryoablation of prostate tissue with temperature monitoring by optoacoustic imaging

    Science.gov (United States)

    Petrova, Elena V.; Motamedi, Massoud; Oraevsky, Alexander A.; Ermilov, Sergey A.

    2016-03-01

    Cryoablation of prostate cancer is an FDA approved clinical procedure, which involves repetitive rapid cooling of a lesion to lethal temperatures of -40°C and below. The major drawback of the technique is the insufficient control over the fast thermal processes that may result in severe complications (impotence, incontinence, perforation of the rectal wall) and morbidity. The developed optoacoustic imaging technique provides non-invasive real-time temperature mapping of tissue adjacent to prostate and enables more efficient control over the procedure, which is necessary to reduce side effects and accelerate the physician's learning curve. In these studies we successfully demonstrated real-time transrectal optoacoustic imaging during prostate cryoablation in live canine model focused on optoacoustic thermography of the rectal wall within the depth of 1cm. Our method utilized previously discovered universal thermal dependence of the normalized optoacoustic response of blood. Nanosecond-pulse radiation of Ti-Sapphire laser tuned to the isosbestic point of hemoglobin (802+/-3 nm) was delivered via fiberoptic illuminators assembled on both sides of the linear array of the 128-channel transrectal ultrasound probe. Temperature readouts at discrete locations inside and nearby prostate were also performed using standard transperineal needle sensors. The effect of homeostasis on optoacoustic imaging in live tissue was examined during cooling and shown to be significant only within the range of +/-1.5°C in respect to the body temperature. Accuracy of in vivo optoacoustic temperature measurements was determined as +/-2°C for the range of temperature from +35 to -15°C, which is more than sufficient for tracking the essential isotherms in the course of clinical procedures.

  18. Evaluation of an Automated Analysis Tool for Prostate Cancer Prediction Using Multiparametric Magnetic Resonance Imaging.

    Directory of Open Access Journals (Sweden)

    Matthias C Roethke

    Full Text Available To evaluate the diagnostic performance of an automated analysis tool for the assessment of prostate cancer based on multiparametric magnetic resonance imaging (mpMRI of the prostate.A fully automated analysis tool was used for a retrospective analysis of mpMRI sets (T2-weighted, T1-weighted dynamic contrast-enhanced, and diffusion-weighted sequences. The software provided a malignancy prediction value for each image pixel, defined as Malignancy Attention Index (MAI that can be depicted as a colour map overlay on the original images. The malignancy maps were compared to histopathology derived from a combination of MRI-targeted and systematic transperineal MRI/TRUS-fusion biopsies.In total, mpMRI data of 45 patients were evaluated. With a sensitivity of 85.7% (with 95% CI of 65.4-95.0, a specificity of 87.5% (with 95% CI of 69.0-95.7 and a diagnostic accuracy of 86.7% (with 95% CI of 73.8-93.8 for detection of prostate cancer, the automated analysis results corresponded well with the reported diagnostic accuracies by human readers based on the PI-RADS system in the current literature.The study revealed comparable diagnostic accuracies for the detection of prostate cancer of a user-independent MAI-based automated analysis tool and PI-RADS-scoring-based human reader analysis of mpMRI. Thus, the analysis tool could serve as a detection support system for less experienced readers. The results of the study also suggest the potential of MAI-based analysis for advanced lesion assessments, such as cancer extent and staging prediction.

  19. Application evaluation of MR diffusion weighted imaging in the diagnosis and differential diagnosis of early prostate cancer

    International Nuclear Information System (INIS)

    Shen Junkang; Lu Yanli; Yang Yi; Zhao Wenlu; Jiang Zhen; Zhang Caiyuan; Ma Qi; Zhang Yongsheng; Shan Yuxi

    2014-01-01

    Objective: To evaluate the value of diffusion weighted imaging (DWI) in the diagnosis and differential diagnosis of early prostate cancer. Methods: The data of 106 patients [35 with early prostate cancer (PCa), 55 with benign prostatic hyperplasia (BPH) and 16 with prostatitis] were retrospectively analyzed, who underwent T 2 WI, DWI, and T 2 WI + DWI examination and all patients were confirmed by pathology. The data obtained from T 2 WI, DWI, and a combination of T 2 WI and DWI were scored and compared with pathological findings. The receiver operating characteristic (ROC) curves were analyzed for the area under the curve (Az) using Z test. Specificities, sensitivities and accuracies of the three protocols to diagnose PCa were evaluated. The ADC values of each prostate lesion were measured and compared with ANOVA test. Results: DWI missed 7 in 35 early prostate cancer, misdiagnosed 2 in 55 BPH, and 11 in 16 prostatitis. The Az values of T 2 WI, DWI, and T 2 WI + DWI for the detection of early prostate cancer were 0.846, 0.874, and 0.947, respectively. There was significant differences between T 2 WI + DWI and T 2 WI alone (Z=3.262, P=0.001), and between T 2 WI + DWI and DWI alone (Z=2.402, P=0.016). There was no significant difference between T 2 WI alone and DWI alone (Z=0.630, P=0.528). The sensitivities, specificities, and accuracies of T 2 WI, DWI, and a combination of T 2 WI and DWI for the detection of early prostate cancer were 51.43% (18/35), 80.00% (28/35), and 85.71% (30/35); 90.14% (64/71), 81.69% (58/71), and 88.73% (63/71); 77.36% (82/106), 81.13% (86/106), and 87.74% (93/106) respectively. The ADC values for detecting early PCa, BPH, and prostatitis were (723 ± 183) ×10 -3 , (1 381 ± 117) × 10 -3 , and (957 ± 175) × 10 -3 mm 2 /s.These ADC values showed statistical significance (F=131.94, P<0.01) among the three groups and also reached statistical significance between each two groups. Conclusions: DWI is valuable in detecting early prostate

  20. Introducing an on-line adaptive procedure for prostate image guided intensity modulate proton therapy.

    Science.gov (United States)

    Zhang, M; Westerly, D C; Mackie, T R

    2011-08-07

    With on-line image guidance (IG), prostate shifts relative to the bony anatomy can be corrected by realigning the patient with respect to the treatment fields. In image guided intensity modulated proton therapy (IG-IMPT), because the proton range is more sensitive to the material it travels through, the realignment may introduce large dose variations. This effect is studied in this work and an on-line adaptive procedure is proposed to restore the planned dose to the target. A 2D anthropomorphic phantom was constructed from a real prostate patient's CT image. Two-field laterally opposing spot 3D-modulation and 24-field full arc distal edge tracking (DET) plans were generated with a prescription of 70 Gy to the planning target volume. For the simulated delivery, we considered two types of procedures: the non-adaptive procedure and the on-line adaptive procedure. In the non-adaptive procedure, only patient realignment to match the prostate location in the planning CT was performed. In the on-line adaptive procedure, on top of the patient realignment, the kinetic energy for each individual proton pencil beam was re-determined from the on-line CT image acquired after the realignment and subsequently used for delivery. Dose distributions were re-calculated for individual fractions for different plans and different delivery procedures. The results show, without adaptive, that both the 3D-modulation and the DET plans experienced delivered dose degradation by having large cold or hot spots in the prostate. The DET plan had worse dose degradation than the 3D-modulation plan. The adaptive procedure effectively restored the planned dose distribution in the DET plan, with delivered prostate D(98%), D(50%) and D(2%) values less than 1% from the prescription. In the 3D-modulation plan, in certain cases the adaptive procedure was not effective to reduce the delivered dose degradation and yield similar results as the non-adaptive procedure. In conclusion, based on this 2D phantom

  1. MR imaging of the prostate at 3 Tesla: comparison of an external phased-array coil to imaging with an endorectal coil at 1.5 Tesla.

    Science.gov (United States)

    Sosna, Jacob; Pedrosa, Ivan; Dewolf, William C; Mahallati, Houman; Lenkinski, Robert E; Rofsky, Neil M

    2004-08-01

    To qualitatively compare the image quality of torso phased-array 3-Tesla (3T) imaging of the prostate with that of endorectal 1.5-Tesla imaging. Twenty cases of torso phased-array prostate imaging performed at 3-Tesla with FSE T2 weighted images were evaluated by two readers independently for visualization of the posterior border (PB), seminal vesicles (SV), neurovascular bundles (NVB), and image quality rating (IQR). Studies were performed at large fields of view(FOV) (25 cm) (14 cases) (3TL) and smaller FOV (14 cm) (19 cases) (3TS). A comparison was made to 20 consecutive cases of 1.5-T endorectal evaluation performed during the same time period.Results. 3TL produced a significantly better image quality compared with the small FOV for PB (P = .0001), SV (P =.0001), and IQR (P = .0001). There was a marginally significant difference within the NVB category (P = .0535). 3TL produced an image of similar quality to image quality at 1.5 T for PB (P = .3893), SV (P = .8680), NB (P = .2684), and IQR (P = .8599). Prostate image quality at 3T with a torso phased-array coil can be comparable with that of endorectal 1.5-T imaging. These findings suggest that additional options are now available for magnetic resonance imaging of the prostate gland.

  2. A Failure Detection Strategy for Intrafraction Prostate Motion Monitoring With On-Board Imagers for Fixed-Gantry IMRT

    International Nuclear Information System (INIS)

    Liu Wu; Luxton, Gary; Xing Lei

    2010-01-01

    Purpose: To develop methods to monitor prostate intrafraction motion during fixed-gantry intensity-modulated radiotherapy using MV treatment beam imaging together with minimal kV imaging for a failure detection strategy that ensures prompt detection when target displacement exceeds a preset threshold. Methods and Materials: Real-time two-dimensional (2D) marker position in the MV image plane was obtained by analyzing cine-MV images. The marker's in-line movement, and thus its time-varying three-dimensional (3D) position, was estimated by combining the 2D projection data with a previously established correlative relationship between the directional components of prostate motion. A confirmation request for more accurate localization using MV-kV triangulation was triggered when the estimated prostate displacement based on the cine-MV data was greater than 3 mm. An interventional action alert followed on positive MV-kV confirmation. To demonstrate the feasibility and accuracy of the proposed method, simulation studies of conventional-fraction intensity-modulated radiotherapy sessions were done using 536 Calypso-measured prostate trajectories from 17 radiotherapy patients. Results: A technique for intrafraction prostate motion management has been developed. The technique, using 'freely available' cine-MV images and minimum on-board kV imaging (on average 2.5 images/fraction), successfully limited 3D prostate movement to within a range of 3 mm relative to the MV beam for 99.4% of the total treatment time. On average, only approximately one intervention/fraction was needed to achieve this level of accuracy. Conclusion: Instead of seeking to accurately and continuously localize the prostate target as existing motion tracking systems do, the present technique effectively uses cine-MV data to provide a clinically valuable way to minimize kV usage, while maintaining high targeting accuracy.

  3. Continuous monitoring of prostate position using stereoscopic and monoscopic kV image guidance

    Energy Technology Data Exchange (ETDEWEB)

    Stevens, M. Tynan R.; Parsons, Dave D.; Robar, James L. [Department of Medical Physics, Dalhousie University, Halifax, Nova Scotia B3H 4R2, Canada and Nova Scotia Cancer Centre, QEII Health Science Centre, Halifax, Nova Scotia B3H 2Y9 (Canada)

    2016-05-15

    Purpose: To demonstrate continuous kV x-ray monitoring of prostate motion using both stereoscopic and monoscopic localizations, assess the spatial accuracy of these techniques, and evaluate the dose delivered from the added image guidance. Methods: The authors implemented both stereoscopic and monoscopic fiducial localizations using a room-mounted dual oblique x-ray system. Recently developed monoscopic 3D position estimation techniques potentially overcome the issue of treatment head interference with stereoscopic imaging at certain gantry angles. To demonstrate continuous position monitoring, a gold fiducial marker was placed in an anthropomorphic phantom and placed on the Linac couch. The couch was used as a programmable translation stage. The couch was programmed with a series of patient prostate motion trajectories exemplifying five distinct categories: stable prostate, slow drift, persistent excursion, transient excursion, and high frequency excursions. The phantom and fiducial were imaged using 140 kVp, 0.63 mAs per image at 1 Hz for a 60 s monitoring period. Both stereoscopic and monoscopic 3D localization accuracies were assessed by comparison to the ground-truth obtained from the Linac log file. Imaging dose was also assessed, using optically stimulated luminescence dosimeter inserts in the phantom. Results: Stereoscopic localization accuracy varied between 0.13 ± 0.05 and 0.33 ± 0.30 mm, depending on the motion trajectory. Monoscopic localization accuracy varied from 0.2 ± 0.1 to 1.1 ± 0.7 mm. The largest localization errors were typically observed in the left–right direction. There were significant differences in accuracy between the two monoscopic views, but which view was better varied from trajectory to trajectory. The imaging dose was measured to be between 2 and 15 μGy/mAs, depending on location in the phantom. Conclusions: The authors have demonstrated the first use of monoscopic localization for a room-mounted dual x-ray system. Three

  4. Comparing the Zeiss Callisto Eye and the Alcon Verion Image Guided System Toric Lens Alignment Technologies.

    Science.gov (United States)

    Hura, Arjan S; Osher, Robert H

    2017-07-01

    To compare the alignment meridian generated by the Zeiss Callisto Eye (Carl Zeiss AG, Dublin, CA) and the Alcon Verion Image Guided System (Alcon Laboratories, Inc., Fort Worth, TX). In this retrospective comparative evaluation of technology, intraoperative images were captured at different steps in the same surgery, allowing the comparison of the guidance lines generated by the Verion system to the parallel guidance lines generated by the Callisto Eye system. Measurements of each hemi-meridian were quantified using Adobe Photoshop 2015 CC software (Adobe Systems, San Jose, CA). The numbers of degrees separating these alignment meridians were calculated, entered into a database, and analyzed. The authors found that of 98 captured images of 16 eyes, the two technologies were identical in 0 eyes (θ 1 = θ 2 = 0), similar by 3° in 52 (53%) captured images (θ 1 ≠ θ 2 ≠ 0), and different by at least 3° in 46 (47%) captured images (θ 1 ≠ θ 2 ≠ 0). The target meridians were superimposed, the target lines were minimally separated, and the target lines were dissimilar. It was noted that some intraoperative variation occurred from measurement to measurement. Within the small group of 16 cases of routine toric lens implantation in this study, the absolute average number of degrees of misalignment between the Verion and Callisto Eye systems was 3.355 for θ 1 and 3.838 for θ 2 . On average, the intraoperative variation termed "drift" was noted to be 3.963° for θ 1 , and 4.557° for θ 2 . The authors found that small deviations were frequent when comparing two sophisticated technologies. Although deviations greater than 3° occurred in less than 47% of captured images from 16 eyes, smaller but significant variations of less than 3° occurred in 53% of captured images from 16 eyes. It was rare to identify a large deviation. However, the authors identified "drift" in the same eye when measurements were taken at different times. The results indicate that the two

  5. Prostate-specific membrane antigen targeted imaging and therapy of prostate cancer using a PSMA inhibitor as a homing ligand.

    Science.gov (United States)

    Kularatne, Sumith A; Wang, Kevin; Santhapuram, Hari-Krishna R; Low, Philip S

    2009-01-01

    Prostate cancer (PCa) is a major cause of mortality and morbidity in Western society today. Current methods for detecting PCa are limited, leaving most early malignancies undiagnosed and sites of metastasis in advanced disease undetected. Major deficiencies also exist in the treatment of PCa, especially metastatic disease. In an effort to improve both detection and therapy of PCa, we have developed a PSMA-targeted ligand that delivers attached imaging and therapeutic agents selectively to PCa cells without targeting normal cells. The PSMA-targeted radioimaging agent (DUPA-(99m)Tc) was found to bind PSMA-positive human PCa cells (LNCaP cell line) with nanomolar affinity (K(D) = 14 nM). Imaging and biodistribution studies revealed that DUPA-(99m)Tc localizes primarily to LNCaP cell tumor xenografts in nu/nu mice (% injected dose/gram = 11.3 at 4 h postinjection; tumor-to-muscle ratio = 75:1). Two PSMA-targeted optical imaging agents (DUPA-FITC and DUPA-rhodamine B) were also shown to efficiently label PCa cells and to internalize and traffic to intracellular endosomes. A PSMA-targeted chemotherapeutic agent (DUPA-TubH) was demonstrated to kill PSMA-positive LNCaP cells in culture (IC(50) = 3 nM) and to eliminate established tumor xenografts in nu/nu mice with no detectable weight loss. Blockade of tumor targeting upon administration of excess PSMA inhibitor (PMPA) and the absence of targeting to PSMA-negative tumors confirmed the specificity of each of the above targeted reagents for PSMA. Tandem use of the imaging and therapeutic agents targeted to the same receptor could allow detection, staging, monitoring, and treatment of PCa with improved accuracy and efficacy.

  6. Tissue mimicking materials for a multi-imaging modality prostate phantom

    International Nuclear Information System (INIS)

    D'Souza, Warren D.; Madsen, Ernest L.; Unal, Orhan; Vigen, Karl K.; Frank, Gary R.; Thomadsen, Bruce R.

    2001-01-01

    Materials that simultaneously mimic soft tissue in vivo for magnetic resonance imaging (MRI), ultrasound (US), and computed tomography (CT) for use in a prostate phantom have been developed. Prostate and muscle mimicking materials contain water, agarose, lipid particles, protein, Cu ++ , EDTA, glass beads, and thimerosal (preservative). Fat was mimicked with safflower oil suffusing a random mesh (network) of polyurethane. Phantom material properties were measured at 22 deg. C. (22 deg. C is a typical room temperature at which phantoms are used.) The values of material properties should match, as well as possible, the values for tissues at body temperature, 37 deg. C. For MRI, the primary properties of interest are T1 and T2 relaxations times, for US they are the attenuation coefficient, propagation speed, and backscatter, and for CT, the x-ray attenuation. Considering the large number of parameters to be mimicked, rather good agreement was found with actual tissue values obtained from the literature. Using published values for prostate parenchyma, T1 and T2 at 37 deg. C and 40 MHz are estimated to be about 1100 and 98 ms, respectively. The CT number for in vivo prostate is estimated to be 45 HU (Hounsfield units). The prostate mimicking material has a T1 of 937 ms and a T2 of 88 ms at 22 deg. C and 40 MHz; the propagation speed and attenuation coefficient slope are 1540 m/s and 0.36 dB/cm/MHz, respectively, and the CT number of tissue mimicking prostate is 43 HU. Tissue mimicking (TM) muscle differs from TM prostate in the amount of dry weight agarose, Cu ++ , EDTA, and the quality and quantity of glass beads. The 18 μm glass beads used in TM muscle increase US backscatter and US attenuation; the presence of the beads also has some effect on T1 but no effect on T2. The composition of tissue-mimicking materials developed is such that different versions can be placed in direct contact with one another in a phantom with no long term change in US, MRI, or CT

  7. Cost minimisation analysis: kilovoltage imaging with automated repositioning versus electronic portal imaging in image-guided radiotherapy for prostate cancer.

    Science.gov (United States)

    Gill, S; Younie, S; Rolfo, A; Thomas, J; Siva, S; Fox, C; Kron, T; Phillips, D; Tai, K H; Foroudi, F

    2012-10-01

    To compare the treatment time and cost of prostate cancer fiducial marker image-guided radiotherapy (IGRT) using orthogonal kilovoltage imaging (KVI) and automated couch shifts and orthogonal electronic portal imaging (EPI) and manual couch shifts. IGRT treatment delivery times were recorded automatically on either unit. Costing was calculated from real costs derived from the implementation of a new radiotherapy centre. To derive cost per minute for EPI and KVI units the total annual setting up and running costs were divided by the total annual working time. The cost per IGRT fraction was calculated by multiplying the cost per minute by the duration of treatment. A sensitivity analysis was conducted to test the robustness of our analysis. Treatment times without couch shift were compared. Time data were analysed for 8648 fractions, 6057 from KVI treatment and 2591 from EPI treatment from a total of 294 patients. The median time for KVI treatment was 6.0 min (interquartile range 5.1-7.4 min) and for EPI treatment it was 10.0 min (interquartile range 8.3-11.8 min) (P value time for EPI was 8.8 min and for KVI was 5.1 min. Treatment time is less on KVI units compared with EPI units. This is probably due to automation of couch shift and faster evaluation of imaging on KVI units. Annual running costs greatly outweigh initial setting up costs and therefore the cost per fraction was less with KVI, despite higher initial costs. The selection of appropriate IGRT equipment can make IGRT practical within radiotherapy departments. Crown Copyright © 2012. Published by Elsevier Ltd. All rights reserved.

  8. Prostate cancer detection from model-free T1-weighted time series and diffusion imaging

    Science.gov (United States)

    Haq, Nandinee F.; Kozlowski, Piotr; Jones, Edward C.; Chang, Silvia D.; Goldenberg, S. Larry; Moradi, Mehdi

    2015-03-01

    The combination of Dynamic Contrast Enhanced (DCE) images with diffusion MRI has shown great potential in prostate cancer detection. The parameterization of DCE images to generate cancer markers is traditionally performed based on pharmacokinetic modeling. However, pharmacokinetic models make simplistic assumptions about the tissue perfusion process, require the knowledge of contrast agent concentration in a major artery, and the modeling process is sensitive to noise and fitting instabilities. We address this issue by extracting features directly from the DCE T1-weighted time course without modeling. In this work, we employed a set of data-driven features generated by mapping the DCE T1 time course to its principal component space, along with diffusion MRI features to detect prostate cancer. The optimal set of DCE features is extracted with sparse regularized regression through a Least Absolute Shrinkage and Selection Operator (LASSO) model. We show that when our proposed features are used within the multiparametric MRI protocol to replace the pharmacokinetic parameters, the area under ROC curve is 0.91 for peripheral zone classification and 0.87 for whole gland classification. We were able to correctly classify 32 out of 35 peripheral tumor areas identified in the data when the proposed features were used with support vector machine classification. The proposed feature set was used to generate cancer likelihood maps for the prostate gland.

  9. A PSMA Ligand Labeled with Cobalt-55 for PET Imaging of Prostate Cancer

    DEFF Research Database (Denmark)

    Dam, Johan Hygum; Olsen, Birgitte Brinkmann; Baun, Christina

    2017-01-01

    PURPOSE: Prostate-specific membrane antigen (PSMA) comprises a recognized target for molecular imaging of prostate cancer. As such, radiolabeled PSMA inhibitors are of great value for diagnosis and staging of this disease. Herein, we disclose the preclinical characterization of [(55)Co]PSMA-617...... for positron emission tomography (PET)/x-ray computed tomography (CT) imaging of prostate cancer lesions. PROCEDURES: By the application of microwave heating, PSMA-617 in acetate buffer (0.4 M, pH 4.4) was labeled with the radioisotopes cobalt-55/57. The extents of internalization and dissociation constants (K...... to the biodistribution in LNCaP xenograft mice, [(57)Co]PSMA-617 displayed a high and relatively constant uptake in the tumor (12.9 %IA/g at 1 h to 10.5 %IA/g at 24 h) with an initial but transient high uptake in the kidneys, adrenals, and spleen. Tumor-to-background ratios improved over time as normal tissue cleared...

  10. MR-CBCT image-guided system for radiotherapy of orthotopic rat prostate tumors.

    Science.gov (United States)

    Chiu, Tsuicheng D; Arai, Tatsuya J; Campbell Iii, James; Jiang, Steve B; Mason, Ralph P; Stojadinovic, Strahinja

    2018-01-01

    Multi-modality image-guided radiotherapy is the standard of care in contemporary cancer management; however, it is not common in preclinical settings due to both hardware and software limitations. Soft tissue lesions, such as orthotopic prostate tumors, are difficult to identify using cone beam computed tomography (CBCT) imaging alone. In this study, we characterized a research magnetic resonance (MR) scanner for preclinical studies and created a protocol for combined MR-CBCT image-guided small animal radiotherapy. Two in-house dual-modality, MR and CBCT compatible, phantoms were designed and manufactured using 3D printing technology. The phantoms were used for quality assurance tests and to facilitate end-to-end testing for combined preclinical MR and CBCT based treatment planning. MR and CBCT images of the phantoms were acquired utilizing a Varian 4.7 T scanner and XRad-225Cx irradiator, respectively. The geometry distortion was assessed by comparing MR images to phantom blueprints and CBCT. The corrected MR scans were co-registered with CBCT and subsequently used for treatment planning. The fidelity of 3D printed phantoms compared to the blueprint design yielded favorable agreement as verified with the CBCT measurements. The geometric distortion, which varied between -5% and 11% throughout the scanning volume, was substantially reduced to within 0.4% after correction. The distortion free MR images were co-registered with the corresponding CBCT images and imported into a commercial treatment planning software SmART Plan. The planning target volume (PTV) was on average 19% smaller when contoured on the corrected MR-CBCT images relative to raw images without distortion correction. An MR-CBCT based preclinical workflow was successfully designed and implemented for small animal radiotherapy. Combined MR-CBCT image-guided radiotherapy for preclinical research potentially delivers enhanced relevance to human radiotherapy for various disease sites. This novel protocol

  11. Ultrasonographic findings in patients with nonbacterial prostatitis

    NARCIS (Netherlands)

    de la Rosette, J. J.; Karthaus, H. F.; Debruyne, F. M.

    1992-01-01

    The potential value of prostatic imaging in the diagnosis of inflammatory disorders of the prostate is largely unexplored. In several studies, specific ultrasonographic characteristics in patients with prostatitis have been described. Also nonspecific echogenic qualities in prostatitis have been

  12. A quantitative analysis of two-dimensional manually segmented transrectal ultrasound axial images in planning high dose rate brachytherapy for prostate cancer

    Directory of Open Access Journals (Sweden)

    Dabić-Stanković Kata

    2017-01-01

    Full Text Available Background/Aim. Prostate delineation, pre-planning and catheter implantation procedures, in high-dose rate brachytherapy (HDR-BT, are commonly based on the prostate manually segmented transrectal ultrasound (TRUS images. The aim of this study was to quantitatively analyze the consistency of prostate capsule delineation, done by a single therapist, prior to each HDR-BT fraction and the changes in the shape of the prostate capsule during HDR-BT, using two dimensional (2D TRUS axial image. Methods. A group of 16 patients were treated at the Medical System Belgrade Brachytherapy Department with definitive HDRBT. The total applied median dose of 52 Gy was divided into four individual fractions, each fraction being delivered 2– 3 weeks apart. Real time prostate axial visualization and the manual segmentation prior to each fraction were performed using B-K Medical ultrasound. Quantitative analyses, analysis of an area and shape were applied on 2D-TRUS axial images of the prostate. Area analyses were used to calculate the average value of the cross-sectional area of the prostate image. The parameters of the prostate shape, the fractal dimension and the circularity ratio of the prostate capsule contour were estimated at the maximum axial cross section of the prostate image. Results. The sample group consisted of four phases, each phase being performed prior to the first, second, third and fourth HDR-BT fraction, respectively. Statistical analysis showed that during HDR-BT fractions there were no significant differences in the average value of area, as well as in the maximum shape of prostate capsule. Conclusions. Quantitative analysis of TRUS axial prostate segmented images shows a successful capsule delineation in the series of manually segmented TRUS images, and the prostate maximum shape remaining unchanged during HDR-BT fractions.

  13. Quantitative PET Imaging with Novel HER3 Targeted Peptides Selected by Phage Display to Predict Androgen Independent Prostate Cancer Progression

    Science.gov (United States)

    2017-08-01

    Independent Prostate Cancer Progression PRINCIPAL INVESTIGATOR: Benjamin Larimer, PhD CONTRACTING ORGANIZATION: Massachusetts General Hospital Boston...3. DATES COVERED 1 Aug 2016 – 31 July 2017 4. TITLE AND SUBTITLE Cancer Progression 5a. CONTRACT NUMBER Quantitative PET Imaging with Novel HER3...Targeted Peptides Selected by Phage Display to Predict Androgen-Independent Prostate Cancer Progression 5b. GRANT NUMBER W81XWH-16-1-0447 5c

  14. A new fiducial marker for Image-guided radiotherapy of prostate cancer: Clinical experience

    Energy Technology Data Exchange (ETDEWEB)

    Carl, Jesper; Nielsen, Jane; Holmberg, Mats; Hoejkjaer Larsen, Erik; Fabrin, Knud; Fisker, Rune V. (Dept. of Medical Physics, Oncology, Aalborg Hospital (Denmark))

    2008-08-15

    Background. A new fiducial marker for image guided radiotherapy (IGRT) based on a removable prostate stent made of Ni Ti has been developed during two previous clinical feasibility studies. The marker is currently being evaluated for IGRT treatment in a third clinical study. Method. The new marker is used to co-register MR and planning CT scans with high accuracy in the region around the prostate. The co-registered MR-CT volumes are used for delineation of GTV before planning. In each treatment session the IGRT system is used to position the patient before treatment. The IGRT system use a stereo pair of kV images matched to corresponding Digital Reconstructed Radiograms (DRR) from the planning CT scan. The match is done using mutual gray scale information. The pair of DRR's for positioning is created in the IGRT system with a threshold in the Look Up Table (LUT). The resulting match provides the necessary shift in couch coordinates to position the stent with an accuracy of 1-2 mm within the planned position. Results. At the present time 39 patients have received the new marker. Of the 39 one has migrated to the bladder. Deviations of more than 5 mm between CTV outlined on CT and MR are seen in several cases and in anterior-posterior (AP), left-right (LR) and cranial-caudal (CC) directions. Intra-fraction translation movements up to +/- 3 mm are seen as well. As the stent is also clearly visible on images taken with high voltage x-rays using electronic portal images devices (EPID), the positioning has been verified independently of the IGRT system. Discussion. The preliminary result of an on going clinical study of a Ni Ti prostate stent, potentially a new fiducial marker for image guided radiotherapy, looks promising. The risk of migration appears to be much lower compared to previous designs

  15. A new fiducial marker for Image-guided radiotherapy of prostate cancer: clinical experience.

    Science.gov (United States)

    Carl, Jesper; Nielsen, Jane; Holmberg, Mats; Højkjaer Larsen, Erik; Fabrin, Knud; Fisker, Rune V

    2008-01-01

    A new fiducial marker for image guided radiotherapy (IGRT) based on a removable prostate stent made of Ni Ti has been developed during two previous clinical feasibility studies. The marker is currently being evaluated for IGRT treatment in a third clinical study. The new marker is used to co-register MR and planning CT scans with high accuracy in the region around the prostate. The co-registered MR-CT volumes are used for delineation of GTV before planning. In each treatment session the IGRT system is used to position the patient before treatment. The IGRT system use a stereo pair of kV images matched to corresponding Digital Reconstructed Radiograms (DRR) from the planning CT scan. The match is done using mutual gray scale information. The pair of DRR's for positioning is created in the IGRT system with a threshold in the Look Up Table (LUT). The resulting match provides the necessary shift in couch coordinates to position the stent with an accuracy of 1-2 mm within the planned position. At the present time 39 patients have received the new marker. Of the 39 one has migrated to the bladder. Deviations of more than 5 mm between CTV outlined on CT and MR are seen in several cases and in anterior-posterior (AP), left-right (LR) and cranial-caudal (CC) directions. Intra-fraction translation movements up to +/- 3 mm are seen as well. As the stent is also clearly visible on images taken with high voltage x-rays using electronic portal images devices (EPID), the positioning has been verified independently of the IGRT system. The preliminary result of an on going clinical study of a Ni Ti prostate stent, potentially a new fiducial marker for image guided radiotherapy, looks promising. The risk of migration appears to be much lower compared to previous designs.

  16. 3D prostate histology image reconstruction: Quantifying the impact of tissue deformation and histology section location

    Directory of Open Access Journals (Sweden)

    Eli Gibson

    2013-01-01

    Full Text Available Background: Guidelines for localizing prostate cancer on imaging are ideally informed by registered post-prostatectomy histology. 3D histology reconstruction methods can support this by reintroducing 3D spatial information lost during histology processing. The need to register small, high-grade foci drives a need for high accuracy. Accurate 3D reconstruction method design is impacted by the answers to the following central questions of this work. (1 How does prostate tissue deform during histology processing? (2 What spatial misalignment of the tissue sections is induced by microtome cutting? (3 How does the choice of reconstruction model affect histology reconstruction accuracy? Materials and Methods: Histology, paraffin block face and magnetic resonance images were acquired for 18 whole mid-gland tissue slices from six prostates. 7-15 homologous landmarks were identified on each image. Tissue deformation due to histology processing was characterized using the target registration error (TRE after landmark-based registration under four deformation models (rigid, similarity, affine and thin-plate-spline [TPS]. The misalignment of histology sections from the front faces of tissue slices was quantified using manually identified landmarks. The impact of reconstruction models on the TRE after landmark-based reconstruction was measured under eight reconstruction models comprising one of four deformation models with and without constraining histology images to the tissue slice front faces. Results: Isotropic scaling improved the mean TRE by 0.8-1.0 mm (all results reported as 95% confidence intervals, while skew or TPS deformation improved the mean TRE by <0.1 mm. The mean misalignment was 1.1-1.9΀ (angle and 0.9-1.3 mm (depth. Using isotropic scaling, the front face constraint raised the mean TRE by 0.6-0.8 mm. Conclusions: For sub-millimeter accuracy, 3D reconstruction models should not constrain histology images to the tissue slice front faces and

  17. A new fiducial marker for Image-guided radiotherapy of prostate cancer: Clinical experience

    International Nuclear Information System (INIS)

    Carl, Jesper; Nielsen, Jane; Holmberg, Mats; Hoejkjaer Larsen, Erik; Fabrin, Knud; Fisker, Rune V.

    2008-01-01

    Background. A new fiducial marker for image guided radiotherapy (IGRT) based on a removable prostate stent made of Ni Ti has been developed during two previous clinical feasibility studies. The marker is currently being evaluated for IGRT treatment in a third clinical study. Method. The new marker is used to co-register MR and planning CT scans with high accuracy in the region around the prostate. The co-registered MR-CT volumes are used for delineation of GTV before planning. In each treatment session the IGRT system is used to position the patient before treatment. The IGRT system use a stereo pair of kV images matched to corresponding Digital Reconstructed Radiograms (DRR) from the planning CT scan. The match is done using mutual gray scale information. The pair of DRR's for positioning is created in the IGRT system with a threshold in the Look Up Table (LUT). The resulting match provides the necessary shift in couch coordinates to position the stent with an accuracy of 1-2 mm within the planned position. Results. At the present time 39 patients have received the new marker. Of the 39 one has migrated to the bladder. Deviations of more than 5 mm between CTV outlined on CT and MR are seen in several cases and in anterior-posterior (AP), left-right (LR) and cranial-caudal (CC) directions. Intra-fraction translation movements up to +/- 3 mm are seen as well. As the stent is also clearly visible on images taken with high voltage x-rays using electronic portal images devices (EPID), the positioning has been verified independently of the IGRT system. Discussion. The preliminary result of an on going clinical study of a Ni Ti prostate stent, potentially a new fiducial marker for image guided radiotherapy, looks promising. The risk of migration appears to be much lower compared to previous designs

  18. Combined spectroscopic imaging and chemometric approach for automatically partitioning tissue types in human prostate tissue biopsies

    Science.gov (United States)

    Haka, Abigail S.; Kidder, Linda H.; Lewis, E. Neil

    2001-07-01

    We have applied Fourier transform infrared (FTIR) spectroscopic imaging, coupling a mercury cadmium telluride (MCT) focal plane array detector (FPA) and a Michelson step scan interferometer, to the investigation of various states of malignant human prostate tissue. The MCT FPA used consists of 64x64 pixels, each 61 micrometers 2, and has a spectral range of 2-10.5 microns. Each imaging data set was collected at 16-1 resolution, resulting in 512 image planes and a total of 4096 interferograms. In this article we describe a method for separating different tissue types contained within FTIR spectroscopic imaging data sets of human prostate tissue biopsies. We present images, generated by the Fuzzy C-Means clustering algorithm, which demonstrate the successful partitioning of distinct tissue type domains. Additionally, analysis of differences in the centroid spectra corresponding to different tissue types provides an insight into their biochemical composition. Lastly, we demonstrate the ability to partition tissue type regions in a different data set using centroid spectra calculated from the original data set. This has implications for the use of the Fuzzy C-Means algorithm as an automated technique for the separation and examination of tissue domains in biopsy samples.

  19. Role of image-guided patient repositioning and online planning in localized prostate cancer IMRT

    International Nuclear Information System (INIS)

    Lerma, Fritz A.; Liu, Bei; Wang, Zhendong; Yi, Byongyong; Amin, Pradip; Liu, Sandy; Feng Yuanming; Yu, Cedric X.

    2009-01-01

    Purpose: To determine the expected benefit of image-guided online replanning over image-guided repositioning of localized prostate cancer intensity-modulated radiotherapy (IMRT). Materials and methods: On 10 to 11 CT scans of each of 10 early-stage prostate cancer patients, the prostate, bladder and rectum are manually segmented. Using a 3-mm PTV margin expansion from the CTV, an IMRT plan is made on the first CT scan of each patient. Online repositioning is simulated by recalculating the IMRT plan from the initial CT scan on the subsequent CT scans of each patient. For online replanning, IMRT is replanned twice on all CT scans, using 0-mm and 3-mm margins. The doses from subsequent CT images of each patient are then deformed to the initial CT anatomy using a mesh-based thin-plate B-spline deformation method and are accumulated for DVH and isodose review. Results: Paired t-tests show that online replanning with 3-mm margins significantly increases the prostate volume receiving the prescribed dose over replanning with 0-mm margins (p-value 0.004); gives marginally better target coverage than repositioning with 3-mm margins(p-value 0.06-0.343), and reduces variations in t