WorldWideScience

Sample records for proportional counters comparacion

  1. Proportional counter end effects eliminator

    International Nuclear Information System (INIS)

    Meekins, J.F.

    1976-01-01

    An improved gas-filled proportional counter which includes a resistor network connected between the anode and cathode at the ends of the counter in order to eliminate ''end effects'' is described. 3 Claims, 2 Drawing Figures

  2. Position sensitive proportional counters as focal plane detectors

    International Nuclear Information System (INIS)

    Ford, J.L.C. Jr.

    1979-01-01

    The rise time and charge division techniques for position decoding with RC-line proportional counters are reviewed. The advantages that these detectors offer as focal plane counters for nuclear spectroscopy performed with magnetic spectrographs are discussed. The theory of operation of proportional counters as position sensing devices is summarized, as well as practical aspects affecting their application. Factors limiting the position and energy resolutions obtainable with a focal plane proportional counter are evaluated and measured position and energy loss values are presented for comparison. Detector systems capable of the multiparameter measurements required for particle identification, background suppression and ray-tracing are described in order to illustrate the wide applicability of proportional counters within complex focal plane systems. Examples of the use of these counters other than with magnetic spectrographs are given in order to demonstrate their usefulness in not only nuclear physics but also in fields such as solid state physics, biology, and medicine. The influence of the new focal plane detector systems on future magnetic spectrograph designs is discussed. (Auth.)

  3. Proportional counter system for radiation measurement

    Energy Technology Data Exchange (ETDEWEB)

    Sugimoto, M; Okudera, S

    1970-11-21

    A gas such as Xe or Kr employed in counter tubes is charged into the counter tube of a gas-flow type proportional counter for radiation measurement and into a vessel having a volume larger than that of the counter tube. The vessel communicates with the counter tube to circulate the gas via a pump through both the vessel and tube during measurement. An organic film such as a polyester synthetic resin film is used for the window of the counter tube to measure X-rays in the long wavelength range. Accordingly, a wide range of X-rays can be measured including both long and short wavelengths ranges by utilizing only one counter tube, thus permitting the gases employed to be effectively used.

  4. Proton-recoil proportional counter tests at TREAT

    International Nuclear Information System (INIS)

    Fink, C.L.; Eichholz, J.J.; Burrows, D.R.; DeVolpi, A.

    1979-01-01

    A methane filled proton-recoil proportional counter will be used as a fission neutron detector in the fast-neutron hodoscope. To provide meaningful fuel-motion information the proportional counter should have: a linear response over a wide range of reactor powers background ratio (the number of high energy neutrons detected must be maximized relative to low energy neutrons, and gamma ray sensitivity must be kept small); and a detector efficiency for fission neutrons above 1 MeV of approximately 1%. In addition, it is desirable that the detector and the associated amplifier/discriminator be capable of operating at counting rates in excess of 500 kHz. This paper reports on tests that were conducted on several proportional counters at the TREAT reactor

  5. Reduction of degraded events in miniaturized proportional counters

    Energy Technology Data Exchange (ETDEWEB)

    Plaga, R.; Kirsten, T. (Max Planck Inst. fuer Kernphysik, Heidelberg (Germany))

    1991-11-15

    A method to reduce the number of degraded events in miniaturized proportional counters is described. A shaping of the outer cathode leads to a more uniform gas gain along the counter axis. The method is useful in situations in which the total number of decay events is very low. The effects leading to degraded events are studied theoretically and experimentally. The usefulness of the method is demonstrated by using it for the proportional counter of the GALLEX solar neutrino experiment. (orig.).

  6. Position-sensitive proportional counter

    International Nuclear Information System (INIS)

    Kopp, M.K.

    1980-01-01

    A position-sensitive proportional counter circuit uses a conventional (low-resistance, metal-wire anode) counter for spatial resolution of an ionizing event along the anode, which functions as an RC line. A pair of preamplifiers at the anode ends act as stabilized active-capacitance loads, each comprising a series-feedback, low-noise amplifier and a unity-gain, shunt-feedback amplifier whose output is connected through a feedback capacitor to the series-feedback amplifier input. The stabilized capacitance loading of the anode allows distributed RC-line position encoding and subsequent time difference decoding by sensing the difference in rise times of pulses at the anode ends where the difference is primarily in response to the distributed capacitance along the anode. This allows the use of lower resistance wire anodes for spatial radiation detection which simplifies the counter construction of handling of the anodes, and stabilizes the anode resistivity at high count rates (>10 6 counts/sec). (author)

  7. X-ray proportional counter for the Viking Lander

    International Nuclear Information System (INIS)

    Glesius, F.L.; Kroon, J.C.; Castro, A.J.; Clark, B.C.

    1978-01-01

    A set of four sealed proportional counters with optimized energy response is employed in the X-ray fluorescence spectrometer units aboard the two Viking Landers. The instruments have provided quantitative elemental analyses of soil samples taken from the Martian surface. This paper discusses the design and development of these miniature proportional counters, and describes their performance on Mars

  8. Neutron dosimetry using proportional counters with tissue equivalent walls

    International Nuclear Information System (INIS)

    Kerviller, H. de

    1965-01-01

    The author reminds the calculation method of the neutron absorbed dose in a material and deduce of it the conditions what this material have to fill to be equivalent to biological tissues. Various proportional counters are mode with walls in new tissue equivalent material and filled with various gases. The multiplication factor and neutron energy response of these counters are investigated and compared with those obtained with ethylene lined polyethylene counters. The conditions of working of such proportional counters for neutron dosimetry in energy range 10 -2 to 15 MeV are specified. (author) [fr

  9. Count rate effect in proportional counters

    International Nuclear Information System (INIS)

    Bednarek, B.

    1980-01-01

    A critical evaluaton is presented of the actual state of investigations and explanations of the resolution and pulse height changes resulted in proportional counters from radiation intensity variations. (author)

  10. DEVELOPMENT OF HETEROGENEOUS PROPORTIONAL COUNTERS FOR NEUTRON DOSIMETRY.

    Science.gov (United States)

    Forouzan, Faezeh; Waker, Anthony J

    2018-01-10

    The use of a custom-made cylindrical graphite proportional counter (Cy-GPC) along with a cylindrical tissue equivalent proportional counter (TEPC) for neutron-gamma mixed-field dosimetry has been studied in the following steps: first, the consistency of the gamma dose measurement between the Cy-TEPC and the Cy-GPC was investigated over a range of 20 keV (X-ray) to 0.661 MeV (Cs-137 gamma ray). Then, with both the counters used simultaneously, the neutron and gamma ray doses produced by a P385 Neutron Generator (Thermo Fisher Scientific) together with a Cs-137 gamma source were determined. © The Author(s) 2018. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  11. Count rate effect in proportional counters

    International Nuclear Information System (INIS)

    Bednarek, B.

    1980-01-01

    A new concept is presented explaining changes in spectrometric parameters of proportional counters which occur due to varying count rate. The basic feature of this concept is that the gas gain of the counter remains constant in a wide range of count rate and that the decrease in the pulse amplitude and the detorioration of the energy resolution observed are the results of changes in the shape of original current pulses generated in the active volume of the counter. In order to confirm the validity of this statement, measurements of the gas amplification factor have been made in a wide count rate range. It is shown that above a certain critical value the gas gain depends on both the operating voltage and the count rate. (author)

  12. Very large area multiwire spectroscopic proportional counters

    International Nuclear Information System (INIS)

    Ubertini, P.; Bazzano, A.; Boccaccini, L.; Mastropietro, M.; La Padula, C.D.; Patriarca, R.; Polcaro, V.F.

    1981-01-01

    As a result of a five year development program, a final prototype of a Very Large Area Spectroscopic Proportional Counter (VLASPC), to be employed in space borne payloads, was produced at the Istituto di Astrofisica Spaziale, Frascati. The instrument is the last version of a new generation of Multiwire Spectroscopic Proportional Counters (MWSPC) succesfully employed in many balloon borne flights, devoted to hard X-ray astronomy. The sensitive area of this standard unit is 2700 cm 2 with an efficiency higher than 10% in the range 15-180 keV (80% at 60 keV). The low cost and weight make this new type of VLASPC competitive with Nal arrays, phoswich and GSPC detectors in terms of achievable scientific results. (orig.)

  13. Very large area multiwire spectroscopic proportional counters

    Energy Technology Data Exchange (ETDEWEB)

    Ubertini, P.; Bazzano, A.; Boccaccini, L.; Mastropietro, M.; La Padula, C.D.; Patriarca, R.; Polcaro, V.F. (Istituto di Astrofisica Spaziale, Frascati (Italy))

    1981-07-01

    As a result of a five year development program, a final prototype of a Very Large Area Spectroscopic Proportional Counter (VLASPC), to be employed in space borne payloads, was produced at the Istituto di Astrofisica Spaziale, Frascati. The instrument is the last version of a new generation of Multiwire Spectroscopic Proportional Counters (MWSPC) successfully employed in many balloon borne flights, devoted to hard X-ray astronomy. The sensitive area of this standard unit is 2700 cm/sup 2/ with an efficiency higher than 10% in the range 15-180 keV (80% at 60 keV). The low cost and weight make this new type of VLASPC competitive with Nal arrays, phoswich and GSPC detectors in terms of achievable scientific results.

  14. An integrated photosensor readout for gas proportional scintillation counters

    International Nuclear Information System (INIS)

    Lopes, J.A.M.; Santos, J.M.F. dos; Conde, C.A.N.

    1996-01-01

    A xenon gas proportional scintillation counter has been instrumented with a novel photosensor that replaces the photomultiplier tube normally used to detect the VUV secondary scintillation light. In this implementation, the collection grid of a planar gas proportional scintillation counter also functions as a multiwire proportional chamber to amplify and detect the photoelectrons emitted by a reflective CsI photocathode in direct contact with the xenon gas. This integrated concept combines greater simplicity, compactness, and ruggedness (no optical window is used) with low power consumption. An energy resolution of 12% was obtained for 59.6 keV x-rays

  15. New proportional counter assembly in Gliwice 14C laboratory

    International Nuclear Information System (INIS)

    Moscicki, W.; Zastawny, A.

    1977-01-01

    The design and parameters are described of a proportional counter for low level counting. The cathode tube 80 mm in diameter and 30 cm in length is made of pure copper. The anode is a tungsten wire 0.05 mm in diameter. The cathode tube is surrounded by a cylindrical ring container with mercury. The total volume of the counter is 1.5 l and it is filled with carbon dioxide. At a pressure of 1 at of CO 2 the counter background is 4.20+-0.05 cpm and contemporary 14 C net effect 10.22+-0.10 cpm; at a pressure of 2 at of CO 2 the background is 4.40+-0.05 cpm and the contemporary 14 C net effect 20.53+-10 cpm. The efficiency of the proportional counter is 88% in both cases. (J.B.)

  16. Calibration of proportional counters in microdosimetry

    International Nuclear Information System (INIS)

    Varma, M.N.

    1982-01-01

    Many microdosimetric spectra for low LET as well as high LET radiations are measured using commercially available (similar to EG and G) Rossi proportional counters. This paper discusses the corrections to be applied to data when calibration of the counter is made using one type of radiation, and then the counter is used in a different radiation field. The principal correction factor is due to differences in W-value of the radiation used for calibration and the radiation for which microdosimetric measurements are made. Both propane and methane base tissue-equivalent (TE) gases are used in these counters. When calibrating the detectors, it is important to use the correct stopping power value for that gas. Deviations in y-bar/sub F/ and y-bar/sub D/ are calculated for 60 Co using different extrapolation procedures from 0.15 keV/μm to zero event size. These deviations can be as large as 30%. Advantages of reporting microdosimetric parameters such as y-bar/sub F/ and y-bar/sub D/ above a certain minimum cut-off are discussed

  17. Multi-element proportional counter for radiation protection measurements

    International Nuclear Information System (INIS)

    Kliauga, P.; Rossi, H.H.; Johnson, G.

    1988-01-01

    This article discusses design modifications of a multi-element proportional counter. The original counter exhibited poor resolution, as measured by the width of the event-size spectrum for low-energy photons. It was also suspected that the field inside each volume was not sufficiently symmetric. Results of the modifications showed that a dramatic improvement in resolution could be obtained in the chamber with tissue-equivalent septa if their potentials were adjusted to obtain optimal resolution. The full width at half maximum then approached, although it did not equal, that of a standard spherical counter

  18. Gas scintillation proportional counters for x-ray synchrotron applications

    International Nuclear Information System (INIS)

    Smith, A.; Bavdaz, M.

    1992-01-01

    Gas scintillation proportional counters (GSPCs) as x-ray detectors provide some advantages and disadvantages compared with proportional counters. In this paper the various configurations of xenon filled GSPC are described including both imaging and nonimaging devices. It is intended that this work be used to configure a GSPC for a particular application and predict its general performance characteristics. The general principles of operation are described and the performance characteristics are then separately considered. A high performance, imaging, driftless GSPC is described in which a single intermediate window is used between the PMT and gas cell

  19. On timing properties of the SRPO-304 proportional counters

    International Nuclear Information System (INIS)

    Gusev, A.A.; Pugacheva, G.I.

    1979-01-01

    Data of measurements of the signal delay time and the time of development of the discharge in a proportional counter filled with 90% Xe + 10% CH 4 mixture at 0.3 atm are presented. The measurements were carried out on muons of cosmic rays. Signal delay distribution for the proportional counter are given relative to the time of passage through it of a charged particle. The data obtained shows that the average delay time is 0.8 μs when a particle passes near the counter centre, whereas when it passes near its side wall the average delay time is 1.5 μs. The investigation of the discharge development time distribution was carried out for two values of the discriminator threshold: 6 and 20 keV. It was determined that the discharge development time distribution depends but little on the place of particle passage in a counter. The average discharge development time is 1.5 μs, with the maximum time beina 4.3 μs. It is shown that the resolution time of logical circuits will be near 4 μs when the counter is combined with scintillation detectors

  20. Proportional counter with a wire-anode lying on the dielectric surface

    International Nuclear Information System (INIS)

    Strelkov, A.V.

    1983-01-01

    Proportional coUnter with wire-anode lying on the dielectric surface is described. The result of the accumulation of charges on the dielectric surface immediately near the wire-anode surface is that such a counter possesses electrostatic memory relative to distribution of the gas amplification coefficient along the anode. SUch a distribution can be received for example by means of irradiation by the neutrons or the γ-rays. The disposition of the wire-anode on the convex dielectric surface allows one to make the ring-shaped counters or the nonplane proportional chambers practically of any profile. However, the energy resolution of the counter with anode on the dielectric is worse than the resolution of counter with free anode particularly at the large gas amplification coefficient

  1. A proportional counter for efficient backscatter Moessbauer effect spectroscopy

    International Nuclear Information System (INIS)

    Pawlowski, Z.; Marzec, J.; Cudny, W.; Holnicka, J.; Walentek, J.

    1979-01-01

    The authors present a novel gas-tight proportional counter with flat beryllium windows for backscatter Moessbauer spectroscopy. The krypton-filled counter has a geometry that approaches 2π and a resolution of 12% fwhm for the 14.4 keV line of 57 Fe, and is easy to manufacture. (Auth.)

  2. Pulse triggering mechanism of air proportional counters

    International Nuclear Information System (INIS)

    Aoyama, T.; Mori, T.; Watanabe, T.

    1983-01-01

    This paper describes the pulse triggering mechanism of a cylindrical proportional counter filled with air at atmospheric pressure for the incidence of β-rays. Experimental results indicate that primary electrons created distantly from the anode wire by a β-ray are transformed into negative ions, which then detach electrons close to the anode wire and generate electron avalanches thus triggering pulses, while electrons created near the anode wire by a β-ray directly trigger a pulse. Since a negative ion pulse is triggered by a single electron detached from a negative ion, multiple pulses are generated by a large number of ions produced by the incidence of a single β-ray. It is therefore necessary not to count pulses triggered by negative ions but to count those by primary electrons alone when use is made of air proportional counters for the detection of β-rays. (orig.)

  3. Position-sensitive proportional counters using resistance-capacitance position encoding

    International Nuclear Information System (INIS)

    Kopp, M.K.; Borkowski, C.J.

    1975-12-01

    A new method was developed for encoding the position of individual photons, neutrons, or charged particles in proportional counters by using the distributed RC line characteristics of these counters. The signal processing is described and guidelines for the design and operation of these position sensitive proportional counters (PSPCs) are given. Using these guidelines, several prototypic PSPCs were constructed to improve the spatial resolution and shorten the signal processing time; for example, the intrinsic spatial uncertainty was reduced to 28 μ fwhm for alpha particles and 100 μ fwhm for low-energy x rays (2 to 6 keV). Also, the signal processing time was reduced to 0.6 μsec without seriously degrading the spatial resolution. These results have opened new fields of application of the RC position encoding method in imaging distributions of photons, charged particles, or neutrons in nuclear medicine, physics, and radiography

  4. The background of external γ radiation in the proportional counters in SAGE experiment

    International Nuclear Information System (INIS)

    Gavrin, V.N.; Gorbachev, V.V.

    2003-01-01

    The influence of external γ radiation on the process of 71 Ge-decay counting in proportional counters in SAGE experiment of solar neutrino flux measurement is examined. One determines the systematic error of SAGE result, connected with radon decays inside the air volume surrounding the counters, and the background counting rate of proportional counters from γ radiation of passive and active shield [ru

  5. Space-charge effects of the proportional counters in a multiple-ionization chamber

    International Nuclear Information System (INIS)

    Mang, M.

    1993-01-01

    At the ALADIN spectrometer of the GSI in october 1991 for the first time the new multiple ionization chamber was applied, in the two anode planes of which are additional multiwire-proportional counters. The proportional counters are required in order to make the detection of light fragments (Z 4 gold projectiles per second by these positive space charges the homogeneous electric field of the MUSIC is disturbed. This effect is especially strong in the beam plane. As consequence of the space charge additionally electrons are focused on the proportional counter so that their amplitudes in dependence on the beam intensity increase up to the 2.5-fold. Furthermore the y coordinate is falsified, because the electrons are diverted to the medium plane. On the measurement of the x coordinate this diversion has with maximally 0.1% only a small influence. These space-charge effects can be qualitatively described by a schematic model, which assumes a stationary positive space charge. Additionally for the proportional counters, which are not in the beam plane, their resolution was determined. In these counters the space-charge effects are small, because essentially fewer particles are registrated than in the medium MWPC's. By this charges of fragments with Z<10 could be separated. The charge resolution amounted at lithium 0.8 charge units. The position resolution of the proportional counters in y direction was determined to less than 8 mm. The detection probability of the fragments amounts for lithium 90% and from boron all fragments are detected

  6. A nuclear proportional counter

    International Nuclear Information System (INIS)

    1973-01-01

    The invention relates to a nuclear proportional counter comprising in a bulb filled with a low-pressure gas, a wire forming an anode and a cathode, characterized in that said cathode is constituted by two plane plates parallel to each other and to the anode wire, and in that two branches of a circuit are connected to the anode wire end-portions, each branch comprising a pre-amplifier, a measuring circuit consisting of a differentiator-integrator-differentiator amplifier and a zero detector, one of the branches comprising an adjustable delay circuit, both branches jointly attacking a conversion circuit for converting the pulse duration into amplitudes said conversion circuit being followed by a multi-channel analyzer, contingently provided with a recorder [fr

  7. Ideal response function of a 3He proportional counter to thermal neutrons determined by different length counters

    International Nuclear Information System (INIS)

    Takeda, Naoto; Kudo, Katsuhisa; Kobayashi, Katsuhei; Yoshimoto, Takaaki

    2000-01-01

    The relative gas multiplication along the cylindrical axis of three 3 He proportional counters with different length were measured by using a thermal neutron beam at the Kyoto University Reactor and an ideal response function by taking into account the difference of pulse height spectra were measured by different length counters. The three 3 He proportional counters (model type of P4-0806, P4-0806 and P4-0808 manufactured by Reuter-Stokes) prepared for relative gas multiplication measurements had identical structure having cylindrical outer shells of 304 stainless steel except for different sensitive lengths of 10 cm, 15 cm and 20 cm, respectively. All counters were filled with 400 kPa of 3 He gas and 200 kPa of Ar gas. The pulse height distributions were measured by moving the counter in the direction of it's cylindrical axis perpendicular to the thermal neutron beam. The measured pulse heights corresponding to the full energy peaks at various entrance points were normalized to that of the whole counter irradiation. The results as a function of the distance from the bottom edge of the stainless steel cylinder are shown. The total transition region of gas gain corresponded to about 23 %, 15 % and 10 % of each nominal sensitive region corresponding to shot, middle and long counters. The ideal pulse height spectrum (dots) obtained by using proportional counters of 10 cm and 20 cm in nominal sensitive length to thermal neutron beam is shown in the paper in comparison to simulated one which was calculated assuming the constant gain within the sensitive region and zero gas gain outside the sensitive regions. The simulation realized the ideal response function fairly well. (S.Y.)

  8. Background of external γ radiation in the proportional counters of the SAGE experiment

    International Nuclear Information System (INIS)

    Gavrin, V.N.; Gorbachev, V.V.

    2003-01-01

    The effect of external γ radiation on the process of counting 71 Ge decays in the proportional counters of the SAGE experiment measuring the solar-neutrino flux is considered. The systematic uncertainty in the SAGE result due to radon decays inside the air volume surrounding the counters is estimated. The background counting rate in the proportional counters that is caused by γ radiation from the enclosing shield is also determined

  9. Pulse-shape discrimination in IAEA tritium proportional counters

    International Nuclear Information System (INIS)

    Florkowski, T.

    1981-01-01

    Two systems of pulse-shape discrimination (PSD) for the reduction of background in low-level proportional counters were tested. A tentative conclusion is drawn that both PSD systems, although they decrease slightly the meson background, do not bring improvement in the analytical accuracy

  10. Performance of microstrip proportional counters for x-ray astronomy on spectrum-roentgen-gamma

    DEFF Research Database (Denmark)

    Budtz-Jørgensen, Carl; BAHNSEN, A; Christensen, Finn Erland

    1991-01-01

    DSRI will provide a set of four imaging proportional counters for the Danish-Soviet X-ray telescopes XSPECT/SODART. The sensor principle is based on the novel micro-strip proportional counter (MSPC), where the strip electrodes are deposited by photolithography onto a rigid substrate. The MSPC off...

  11. Novel concept for neutron detection: proportional counter filled with 10B nanoparticle aerosol

    Science.gov (United States)

    Amaro, F. D.; Monteiro, C. M. B.; dos Santos, J. M. F.; Antognini, A.

    2017-01-01

    The high neutron detection efficiency, good gamma-ray discrimination and non-toxicity of 3He made of proportional counters filled with this gas the obvious choice for neutron detection, particularly in radiation portal monitors (RPM), used to control the illicit transport of nuclear material, of which neutron detectors are key components. 3He is very rare and during the last decade this gas has become increasingly difficult to acquire. With the exception of BF3, which is toxic, no other gas can be used for neutron detection in proportional counters. We present an alternative where the 3He atoms are replaced by nanoparticles made of another neutron sensitive material, 10B. The particles are dispersed in a gaseous volume, forming an aerosol with neutron sensitive properties. A proportional counter filled with such aerosol was exposed to a thermal neutron beam and the recorded response indicates that the neutrons have interacted with the particles in the aerosol. This original technique, which transforms a standard proportional gas mixture into a neutron sensitive aerosol, is a breakthrough in the field of radiation detection and has the potential to become an alternative to the use of 3He in proportional counters. PMID:28181520

  12. Digital signal processing for 3He proportional counters

    International Nuclear Information System (INIS)

    Takahashi, Hiroyuki; Kawarabayashi, Jun; Kurahashi, Tomohiko; Iguchi, Tetsuo; Nakazawa, Masaharu

    1994-01-01

    Numerical analysis of individual pulses from 3 He proportional counters has been performed. A parametric approach has been used for the identification of a charge particle track direction. Using area parameters, a clear separation of events was observed for the wall effect on a triton and a proton, respectively. ((orig.))

  13. A comparison between the measurements of Kr-85 in environmental samples by liquid scintillation and proportional counters; Comparacion de resultados de la medida radiactiva del Kr-85 ambiental por centelleo liquido y contadores proporcionales

    Energy Technology Data Exchange (ETDEWEB)

    Heras, M. C.; Perez, M. M.

    1983-07-01

    The most used methods for the measurement of Kr-81 beta-activity after their concentration and aisolation are the liquid scintillation counting and the proportional counter. In this work the beta activity of concentrated and aisolated Kr-85 samples measured in collaboration with the Max-Planck Institut fur Kernphyslk, Aussenstelle Freiburg. Samples taken both In Madrid and Frelburg are measured by proportional counters in the Max-Planck lnstitut, Freibury and by liquid scintillation counting in JEN, Madrid. The comparison of both measurements do not show appreciable discrepancy between the results obtained to both techniques. (Author)

  14. Position-sensitive proportional counter with low-resistance metal-wire anode

    International Nuclear Information System (INIS)

    Kopp, M.K.

    1980-01-01

    A position-sensitive proportional counter circuit is provided which uses a conventional (low-resistance, metal-wire anode) proportional counter for spatial resolution of an ionizing event along the anode of the counther. A pair of specially designed activecapacitance preamplifiers terminate the anode ends wherein the anode is treated as an RC line. The preamplifiers act as stabilized active capacitance loads and each is composed of a series-feedback, lownoise amplifier, a unity-gain, shunt-feedback amplifier whose output is connected through a feedback capacitor to the series-feedback amplifier input. The stabilized capacitance loading of the anode allows distributed RC-line position encoding and subsequent time difference decoding by sensing the difference in rise times of pulses at te anode ends where the difference is primarily in response to the distributed capacitance along the anode. This allows the use of lower resistance wire anodes for spatial radiation detection which simplifies the counter construction and handling of the anodes, and stabilizes the anode resistivity at high count rates

  15. Proportional counter response calculations for gallium solar neutrino detectors

    International Nuclear Information System (INIS)

    Kouzes, R.T.; Reynolds, D.

    1989-01-01

    Gallium bases solar neutrino detectors are sensitive to the primary pp reaction in the sun. Two experiments using gallium, SAGE in the Soviet Union and GALLEX in Europe, are under construction and will produce data by 1989. The radioactive /sup 71/Ge produced by neutrinos interacting with the gallium detector material, is chemically extracted and counted in miniature proportional counters. A number of calculations have been carried out to simulate the response of these counters to the decay of /sup 71/Ge and to background events

  16. On the counting rate-dependent amplitude shifts in proportional counters

    International Nuclear Information System (INIS)

    Mahesh, K.

    1976-01-01

    The presence of a positive ion cloud near the anode wire, which has been believed to be the cause of the observed counting rate-dependent peak shifts in proportional counters, does not explain various exhibited features of these shifts. The possibility of other mechanisms involved is, therefore, examined. The columnar recombination of primary ions in the counter is considered to explain the origin of the shifts and their observed features. (Auth.)

  17. Proportional Counter Calibration and Analysis for 12C + p Resonance Scattering

    Science.gov (United States)

    Nelson, Austin; Rogachev, Grigory; Uberseder, Ethan; Hooker, Josh; Koshchiy, Yevgen

    2014-09-01

    Light exotic nuclei provide a unique opportunity to test the predictions of modern ab initio theoretical calculations near the drip line. In ab initio approaches, nuclear structure is described starting from bare nucleon-nucleon and three-nucleon interactions. Calculations are very heavy and can only be performed for the lightest nuclei (A objective of this project was to test the performance and perform position calibration of this proportional counter array. The test was done using 12C beam. The excitation function for 12C + p elastic scattering was measured and calibration of the proportional counter was performed using known resonances in 13N. The method of calibration, including solid angle calculations, normalization corrections, and position calibration will be presented. Light exotic nuclei provide a unique opportunity to test the predictions of modern ab initio theoretical calculations near the drip line. In ab initio approaches, nuclear structure is described starting from bare nucleon-nucleon and three-nucleon interactions. Calculations are very heavy and can only be performed for the lightest nuclei (A objective of this project was to test the performance and perform position calibration of this proportional counter array. The test was done using 12C beam. The excitation function for 12C + p elastic scattering was measured and calibration of the proportional counter was performed using known resonances in 13N. The method of calibration, including solid angle calculations, normalization corrections, and position calibration will be presented. Funded by DOE and NSF-REU Program; Grant No. PHY-1263281.

  18. Proportional counter with uniform electric field with Penning's mixture

    International Nuclear Information System (INIS)

    Pawlowski, Z.; Marzec, J.; Zaremba, K.

    1984-01-01

    Some calculations are given and the design of proportional counters with a homogeneous electric field filled with Penning's mixtures, which ensure the best energy resolution is described. The counters with mixtures of Ne+Ar, Ne+CH 4 , Ne+CO 2 and Ar+C 2 H 2 have been checked. The admixtures (Ar, CH 4 , CO 2 , C 2 H 2 ) constitute from 0.1 to 2%, with pressure from 125 Tr to 760 Torr. The best energy resolution has been obtained for the mixture of Ne+1%CH 4 at the pressure of 190 Torr

  19. Nitrogen large area proportional counter with gas regeneration

    International Nuclear Information System (INIS)

    Leidner, L.; Sadri, E.

    1984-10-01

    A nitrogen large area proportional chamber with gas regeneration is introduced to measure alpha and beta/gamma activites. In contrast to the flow counters used till now the new detector is independent of an external gas supply. The gas amplification factor of nitrogen keeps constant up to an impurity of 2% of O 2 . Oxygen diffusing through unavoidable leakages into the counting gas is removed by an activated catalyzer using low temperature copper oxidation. Humidty is adsorbed by a molecular sieve. The closed counter consists of three components: the actual detector, a gas purification cartridge and a gas circulating pump. Finally, the report describes long run experiments being carried out with prototypes. (orig./HP) [de

  20. Improving the performance of X-ray proportional counters by using field transistor preamplifiers

    International Nuclear Information System (INIS)

    Kalinina, N.I.; Mel'ttser, L.V.; Pan'kin, V.V.

    1972-01-01

    The possibility of using low-noise field-effect transistors with the n-channel in preamplifiers for x-ray proportional counters constitutes the object of this article. The operation of the preamplifier assembled according to the scheme of the voltage amplifier and charge-sensitive preamplifier has been studied. The use of the field-effect transistor with the n-channel in preamplifiers for proportional counters allows to improve significantly the energy resolution and operation at reduced voltage and at high loads. Notably good results have been obtained when constructing the circuit of the premplifier with the field-effect transistor on the charge-sensitive principle. The use of home-produced field-effect transistors makes it possible to construct detectors of roentgen radiometric instruments to measure light element content with proportional counters at reduced voltage

  1. Avalanche localization and its effects in proportional counters

    International Nuclear Information System (INIS)

    Fischer, J.; Okuno, H.; Walenta, A.H.

    1977-11-01

    Avalanche development around the anode wire in a gas proportional counter is investigated. In the region of proportional gas amplification, the avalanche is found to be well localized on one side of the anode wire, where the electrons arrive along the field lines from the point of primary ionization. Induced signals on electrodes surrounding the anode wire are used to measure the azimuthal position of the avalanche on the anode wire. Practical applications of the phenomena such as left-right assignment in drift chambers and measurement of the angular direction of the primary ionization electrons drifting towards the anode wire are discussed

  2. Energy resolution limitations in a gas scintillation proportional counter

    International Nuclear Information System (INIS)

    Simons, D.G.; de Korte, P.A.J.; Peacock, A.; Bleeker, J.A.M.

    1985-01-01

    An investigation is made of the factors limiting the energy resolution of a gas scintillation proportional counter (GSPC). Several of these limitations originate in the drift region of such a counter and data is presented, giving a quantitative description of those effects. Data is also presented of a GSPC without a drift region, that therefore largely circumvents most of those degrading factors. The results obtained so far indicate that in that detector the limitation to the resolution is most probably due to cleanliness of the gas. Further research is underway in order to assess quantitatively the limiting factors in such a driftless GSPC

  3. Some aspects of the use of proton recoil proportional counters for fast neutron personnel dosimeters

    International Nuclear Information System (INIS)

    Yule, T.J.; Bennett, E.F.

    1984-01-01

    Gas-filled proton recoil proportional counters have been used extensively for the measurement of neutron spectra in degraded fission-spectrum environments. Some considerations relating to the use of these counters for personnel dosimetry are here described. High sensitivity and good accuracy in the determination of dose-equivalent can be obtained if relatively high pressure hydrogen-filled proportional counters are used as the active element in a dosimeter system

  4. Methods of calculus for neutron spectrometry in proportional counters

    International Nuclear Information System (INIS)

    Butragueno, J.L.; Blazquez, J.B.; Barrado, J.M.

    1976-01-01

    Response functions for cylindrical proportional counters with hidrogenated gases have been determined, taking in account only wall effect, by means of two independent calculus methods. One of them is a Montecarlo application and the other one analytical at all. Results of both methods have been compared. (author) [es

  5. Methods of calculus for neutron spectrometry in proportional counters

    International Nuclear Information System (INIS)

    Butragueno Casado, J.L.; Blazquez Martinez, J.B.; Barrado Menendez, J.M.

    1976-01-01

    Response functions for cylindrical proportional counters with hydrogenated gases have been determined, taking in account only wall effect, by means of two independent calculus methods. One of them is a Monte Carlo application and the other one analytica at all. Results of both methods have been compared. (Author)

  6. Design of a hybrid gas proportional counter with CdTe guard counters for sup 1 sup 4 C dating system

    CERN Document Server

    Zhang, L; Hinamoto, N; Nakazawa, M; Yoshida, K

    2002-01-01

    Nowadays uniform, low-cost and large-size compound semiconductor detectors are available up to several square centimeters. We are trying to combine this technology with conventional gas detectors to upgrade an anticoincidence type proportional counter, Oeschger-type thin wall counter of 2.2 l, used for a sup 1 sup 4 C dating facility at the University of Tokyo. In order to increase the ratio of the signal to the background for smaller quantity of samples less than 1 g, an effective approach is to minimize the detector volume at higher gas pressure. However, the anticoincidence function suffers from such a small volume. Therefore we designed a new active wall gas counter of 0.13 l counting volume using CdTe compound semiconductor detectors as the wall of the gas proportional counter to perform anticoincidence. Simulation study showed that at noise thresholds less than 70 keV, the wall counters can reject above 99.8% of events arising from outer gamma rays. Measured noise levels of CdTe detectors were smaller t...

  7. Development of a drift tissue equivalent proportional counter for radiation protection personnel dosimetry

    International Nuclear Information System (INIS)

    Bordy, J.M.

    1992-04-01

    A new multicellular geometry for proportional counter has been developed. It is made of several drift regions which are some holes drilled in the cathode in front of anodes wires. The present work is made of 3 parts: 1) A theoretical evaluation of the multicellular counter characteristics: the sensitivity increases by a factor 15 vs the Tinelli Merlin-Gerin counter; the chord length distribution study shows the possibility to use a Dirac function for the dosimetry calculations; a tissue equivalent gas mixture based on argon and propane is designed. 2) The production of a monocellular prototype made of a hole and a needle shaped anode. 3) An experimental study of the prototype electrical characteristics and a computation of the electrical field in the counter. The focalization and the electron drift into the hole, the proportional operating mode are shown. Irradiations in front of photon and neutron sources verify these results

  8. Xenon-based Penning mixtures for proportional counters

    International Nuclear Information System (INIS)

    Ramsey, B.D.; Agrawal, P.C.; National Aeronautics and Space Administration, Huntsville, AL

    1989-01-01

    The choice of quench gas can have a significant effect on the gas gain and energy resolution of gas-filed proportional counters. Details are given on the performance obtained with a variety of quench additives of varying ionization potentials for use in xenon-filled systems. It is confirmed that optimum performance is obtained when the ionization potential is closely matched to the first metastable level of xenon (8.3 eV) as is the case with xenon + trimethylamine and xenon + dimethylamine. For these mixtures the Penning effect is at its strongest. (orig.)

  9. Development of proportional counters using photosensitive gases and liquids

    International Nuclear Information System (INIS)

    Anderson, D.F.

    1984-10-01

    An introduction to the history and to the principle of operation of wire chambers using photosensitive gases and liquids is presented. Their use as light sensors coupled to Gas Scintillation Proportional Counters and BaF 2 , as well as their use in Cherenkov Ring imaging, is discussed in some detail. 42 references, 21 figures

  10. Proton-recoil proportional-counter array for neutron-image construction

    International Nuclear Information System (INIS)

    Fink, C.L.; Eichholz, J.J.; DeVolpi, A.

    1984-01-01

    The fuel-motion measurement capability of the fast-neutron hodoscope has been upgraded by the addition of a 360-detector proton-recoil proportional-counter array, which detects high-energy fission neutrons. The current sensitive amplifier/discriminator module for each detector fits into a 12.7 by 12.7 by 102 mm package and cost less than $100 per module. It has a 50 ns rise time, a noise level of 100 nA, and a deadtime per event of 200 ns. Provision has been provided for the independent adjustment of the input current versus discriminator voltage for each module. The new proportional-counters cost approximately $400 each. Each detector has been tested to have the same gain versus voltage response. A space-charge model relating count-rate changes to space-charge effects has also been developed. The new detector array has been operational for approximately two years and has become the main detector system in fuel-motion analysis. It has significantly improved the linearity, stability, count-rate capability, and setup ease of the hodoscope

  11. 39Ar/Ar measurements using ultra-low background proportional counters

    International Nuclear Information System (INIS)

    Hall, Jeter; Aalseth, Craig E.; Bonicalzi, Ricco M.; Brandenberger, Jill M.; Day, Anthony R.; Humble, Paul H.; Mace, Emily K.; Panisko, Mark E.; Seifert, Allen

    2016-01-01

    Age-dating groundwater and seawater using the 39 Ar/Ar ratio is an important tool to understand water mass-flow rates and mean residence time. Low-background proportional counters developed at Pacific Northwest National Laboratory use mixtures of argon and methane as counting gas. We demonstrate sensitivity to 39 Ar by comparing geological (ancient) argon recovered from a carbon dioxide gas well and commercial argon. The demonstrated sensitivity to the 39 Ar/Ar ratio is sufficient to date water masses as old as 1000 years. - Highlights: • 39 Ar/Ar age dating is important for understanding environmental water migration. • Ultra low background proportional counters have been developed. • 39 Ar is detected in atmospheric argon at a rate of 70.3 counts per day. The demonstrated background is 166 counts per day. • Age dating is possible for water with underground residence time of up to 1000 years.

  12. Calibration methodology for proportional counters applied to yield measurements of a neutron burst

    Energy Technology Data Exchange (ETDEWEB)

    Tarifeño-Saldivia, Ariel, E-mail: atarifeno@cchen.cl, E-mail: atarisal@gmail.com; Pavez, Cristian; Soto, Leopoldo [Comisión Chilena de Energía Nuclear, Casilla 188-D, Santiago (Chile); Center for Research and Applications in Plasma Physics and Pulsed Power, P4, Santiago (Chile); Departamento de Ciencias Fisicas, Facultad de Ciencias Exactas, Universidad Andres Bello, Republica 220, Santiago (Chile); Mayer, Roberto E. [Instituto Balseiro and Centro Atómico Bariloche, Comisión Nacional de Energía Atómica and Universidad Nacional de Cuyo, San Carlos de Bariloche R8402AGP (Argentina)

    2014-01-15

    This paper introduces a methodology for the yield measurement of a neutron burst using neutron proportional counters. This methodology is to be applied when single neutron events cannot be resolved in time by nuclear standard electronics, or when a continuous current cannot be measured at the output of the counter. The methodology is based on the calibration of the counter in pulse mode, and the use of a statistical model to estimate the number of detected events from the accumulated charge resulting from the detection of the burst of neutrons. The model is developed and presented in full detail. For the measurement of fast neutron yields generated from plasma focus experiments using a moderated proportional counter, the implementation of the methodology is herein discussed. An experimental verification of the accuracy of the methodology is presented. An improvement of more than one order of magnitude in the accuracy of the detection system is obtained by using this methodology with respect to previous calibration methods.

  13. Calibration methodology for proportional counters applied to yield measurements of a neutron burst

    International Nuclear Information System (INIS)

    Tarifeño-Saldivia, Ariel; Pavez, Cristian; Soto, Leopoldo; Mayer, Roberto E.

    2014-01-01

    This paper introduces a methodology for the yield measurement of a neutron burst using neutron proportional counters. This methodology is to be applied when single neutron events cannot be resolved in time by nuclear standard electronics, or when a continuous current cannot be measured at the output of the counter. The methodology is based on the calibration of the counter in pulse mode, and the use of a statistical model to estimate the number of detected events from the accumulated charge resulting from the detection of the burst of neutrons. The model is developed and presented in full detail. For the measurement of fast neutron yields generated from plasma focus experiments using a moderated proportional counter, the implementation of the methodology is herein discussed. An experimental verification of the accuracy of the methodology is presented. An improvement of more than one order of magnitude in the accuracy of the detection system is obtained by using this methodology with respect to previous calibration methods

  14. Absolute measurement of the activity of 222Rn using a proportional counter

    International Nuclear Information System (INIS)

    Busch, Ingo; Greupner, Heinz; Keyser, Uwe

    2002-01-01

    A measuring set-up comprising a proportional counter of calculable 222 Rn efficiency and quantifiable active volume (δ V 222 Rn efficiency is determined by computer simulation of the measured α-spectra. The procedures necessary for absolute measurements by means of the counter are described, and the suitability of the counter for absolute measurements of the 222 Rn activity is proved by experiments. Thus, a new method for the realization of the unit of activity of 222 Rn is obtained, which is independent of the unit of activity of 226 Ra

  15. Measurements of electron attachment by oxygen molecule in proportional counter

    Energy Technology Data Exchange (ETDEWEB)

    Tosaki, M., E-mail: tosaki.mitsuo.3v@kyoto-u.ac.jp [Radioisotope Research Center, Kyoto University, Kyoto 606-8501 (Japan); Kawano, T. [National Institute for Fusion Science, 322-6 Oroshi, Toki 509-5292 (Japan); Isozumi, Y. [Radioisotope Research Center, Kyoto University, Kyoto 606-8501 (Japan)

    2013-11-15

    We present pulse height measurements for 5-keV Auger electrons from a radioactive {sup 55}Fe source mounted at the inner cathode surface of cylindrical proportional counter, which is operated with CH{sub 4} admixed dry air or N{sub 2}. A clear shift of the pulse height has been observed by varying the amount of the admixtures; the number of electrons, created in the primary ionization by Auger electrons, is decreased by the electron attachment of the admixtures during their drift from the place near the source to the anode wire. The large gas amplification (typically 10{sup 4}) in the secondary ionization of proportional counter makes it possible to investigate a small change in the number of primary electrons. The electron attenuation cross-section of O{sub 2} has been evaluated by analyzing the shifts of the pulse height caused by the electron attachment to dry air and N{sub 2}.

  16. X-ray polarimetry with a conventional gas proportional counter through rise-time analysis

    CERN Document Server

    Hayashida, K; Tsunemi, H; Torii, K; Murakami, H; Ohno, Y; Tamura, K

    1999-01-01

    We have performed an experiment on the signal rise time of a Xe gas proportional counter using a polarized X-ray beam of synchrotron orbital radiation with energies from 10 to 40 keV. When the counter anode is perpendicular to the electric vector of the incident X-ray photons, the average rise time becomes significantly longer than that for the parallel case. This indicates that the conventional gas proportional counters are useful for X-ray polarimetry. The moderate modulation contrast of this rise-time polarimeter (M=0.1 for 10 keV X-rays and M=0.35 for 40 keV X-rays), with capability of the simultaneous measuring X-ray energies and the timing, would be useful for applications in X-ray astronomy and in other fields.

  17. Experimental dead time corrections for a linear position-sensitive proportional counter

    International Nuclear Information System (INIS)

    Yelon, W.B.; Tompson, C.W.; Mildner, D.F.R.; Berliner, R.; Missouri Univ., Columbia

    1984-01-01

    Two simple counters included in the charge-digitization circuitry of a position-sensitive proportional counter using the charge division method for position encoding have enabled us to determine the dead time losses for the system. An interesting positional dependence of the dead time tau is observed, which agrees with a simple model. The system enables us to correct the experimental data for dead time and to be indifferent to the relatively slow analog-to-digital converters used in the system. (orig.)

  18. Study and construction of an air proportional counter for superficial alpha contamination

    International Nuclear Information System (INIS)

    Cabral, T.S.

    1991-01-01

    Some properties of the proportional counters such as the working principle and the process of the gaseous multiplication are presented. Besides that, the project of Multiwire Proportional Counters is shown, which was tested with anodic wires of different diameters and with windows of several thicknesses. Operational characteristics of the detector were determined with the quoted variations. The chamber was normally operated by atmospheric pressure, but there were also made surveys on its behavior with oxygen, nitrogen and mixture of both. The performance of the chamber with a variations of temperature and relative humidity is analysed, because that is one of the biggest problems faced when measure of field are being made with this kind of detector. (author)

  19. Feasibility studies of high-pressure 4π proportional counter for absolute activity measurement

    International Nuclear Information System (INIS)

    Hino, Y.; Kawada, Y.

    1988-01-01

    A high-pressure proportional counter system is constructed. The high pressure 4πβ counter system constructed is made of aluminum and is divided into two 2π counters. The gas pressure is controlled with a pressure regulator and very fine leak valves to keep the balance of a stable pressure and constant flow rate. Investigation of characteristics of th counter shows that there is an almost linear relation between voltage and pressure. The linearlity of gas gain of this counter to the electron energies is measured with different gas pressures. Quite good linear gas multiplication is obtained at 0.9 MPa. Another investigation is made of application of to activity measurement of 109 Cd. When the gas pressure is over 0.5 MPa, the proportion of collected conversion electrons to absolute activity comes to a constant value of 96 %. This is quite good agreement with the decay data of 96.4 % conversion electron emission rate. The study indicated many excellent features for activity measurement. Especially the efficiency variation technique is good for automatic data acquisition with a programmable high voltage supplier. Moreover, since it is possible to obtain absolute activity with only one sample, it will be quite useful for limited samples experiments. (N.K.)

  20. Rate dependent image distortions in proportional counters

    International Nuclear Information System (INIS)

    Trow, M.W.; Bento, A.C.; Smith, A.

    1994-01-01

    The positional linearity of imaging proportional counters is affected by the intensity distribution of the incident radiation. A mechanism for this effect is described, in which drifting positive ions in the gas produce a distorting electric field which perturbs the trajectories of the primary electrons. In certain cases, the phenomenon causes an apparent improvement of the position resolution. We demonstrate the effect in a detector filled with a xenon-argon-CO 2 mixture. The images obtained are compared with the results of a simulation. If quantitative predictions for a particular detector are required, accurate values of the absolute detector gain, ion mobility and electron drift velocity are needed. ((orig.))

  1. Quench gases for xenon- (and krypton-)filled proportional counters

    International Nuclear Information System (INIS)

    Ramsey, B.D.; Agrawal, P.C.

    1988-01-01

    Xenon-filled proportional counters are used extensively in astronomy, particularly in the hard X-ray region. The choice of quench gas can have a significant effect on the operating characteristics of the instrument although the data necessary to make the choice are not easily obtainable. We present results which detail the performance obtained from both cylindrical and parallel field geometries for a wide variety of readily available, ultrahigh or research grade purity, quench gases. (orig.)

  2. Investigation of the Pulse Height Distribution of Boron Trifluoride Proportional Counters

    Energy Technology Data Exchange (ETDEWEB)

    Andersson, I Oe; Malmskog, S

    1962-08-15

    The report describes a theoretical and experimental investigation of the factors that determine the pulse height distribution of BF{sub 3}, proportional counters irradiated by thermal neutrons. The branching ratio of the {sup 10}B (n,{alpha}) {sup 7}Li reaction for thermal neutrons has been measured.

  3. Position sensitive proportional counter for measurement of tritium labelled gas movement

    International Nuclear Information System (INIS)

    Mori, Chizuo; Nakamoto, Makihiko; Uritani, Akira; Watanabe, Tamaki

    1984-01-01

    A position sensitive proportional counter of a charge division type with a single resistive anode wire was constructed for the measurement of the movement of 3 H labelled gas which is flowing or diffusing in a pipe. The introduction of resistors between the anode wire and pre-amplifiers brought a uniform detection efficiency for 3 H β-rays throughout the counter. The position resolution was 3.1 mm FWHM. Detection efficiency was almost 100% uniformly over about 700 mm in the total anode length of 740 mm. The movement of 3 H labelled gas could be measured effectively. (author)

  4. Study on the neutron dosimetric characteristics of Tissue Equivalent Proportional Counter

    Energy Technology Data Exchange (ETDEWEB)

    Nunomiya, T.; Kim, E.; Kurosawa, T.; Taniguchi, S.; Nakamura, T. [Tohoku Univ., Sendai (Japan). Cyclotron and Radioisotope Center; Tsujimura, N.; Momose, T.; Shinohara, K. [Japan Nuclear Cycle Development Inst., Environment and Safety Division, Tokai Works, Tokai, Ibaraki (Japan)

    1999-03-01

    The neutron dosimetric characteristics of TEPC (Tissue Equivalent Proportional Counter) has been investigated under a cooperative study between Tohoku University and JNC since 1997. This TEPC is a spherical, large volume, single-wire proportional counter (the model LETSW-5, manufactured by Far West Technology, Inc.) and filled with a tissue equivalent gas in a spherical detector of the A-150 tissue equivalent plastic. The TEPC can measure the spectra of absorbed dose in LET and easily estimate the tissue equivalent dose to neutron. This report summarizes the dosimetric characteristics of TEPC to the monoenergetic neutrons with energy from 8 keV to 15 MeV. It is found that TEPC can estimate the ambient dose equivalent, H*(10), with an accuracy from 0.9 to 2 to the neutron above 0.25 MeV and TEPC has a good counting efficiency enough to measure neutron doses with low dose rate at the stray neutron fields. (author)

  5. Application of the finite-difference approximation to electrostatic problems in gaseous proportional counters

    International Nuclear Information System (INIS)

    Waligorski, M.P.R.; Urbanczyk, K.M.

    1975-01-01

    The basic principles of the finite-difference approximation applied to the solution of electrostatic field distributions in gaseous proportional counters are given. Using this method, complicated two-dimensional electrostatic problems may be solved, taking into account any number of anodes, each with its own radius, and any cathode shape. A general formula for introducing the anode radii into the calculations is derived and a method of obtaining extremely accurate (up to 0.1%) solutions is developed. Several examples of potential and absolute field distributions for single rectangular and multiwire proportional counters are calculated and compared with exact results according to Tomitani, in order to discuss in detail errors of the finite-difference approximation. (author)

  6. Proceedings of the symposium on measurements of neutron energy spectra using recoil proton proportional counters

    International Nuclear Information System (INIS)

    Urabe, Itsumasa

    1986-01-01

    This is a report of the symposium on measurements of neutron energy spectra using recoil proton proportional counters held at the Research Reactor Institute of Kyoto University on January 27 in 1986. An energy resolution, wall effects of response functions, n · γ discrimination methods and other fundamental properties of recoil proton counters are discussed for a new development of an application of this counter. (author)

  7. Neutron spectrometry with proton recoil proportional counters at the research and measurement reactor Braunschweig - status of the technique

    International Nuclear Information System (INIS)

    Knauf, K.; Wittstock, J.

    1987-07-01

    This status report is concerned with the facilities set up for neutron spectrometry at the Research and Measurement Reactor Braunschweig, based on proton recoil proportional counters. Cylindrical counters for irradiation by a neutron beam normal to the counter wire and commercial spherical counters are employed. They can be filled with hydrogen or a hydrogeneous gas up to a pressure of 1 MPa depending on their use. The filling method and the electronic pulse processing are described. The pulse analysis system includes a pulse shape discrimination branch in order to separate γ-ray induced pulses. Finally, experimental investigations with spherical counters are discussed regarding the region of proportionality and the influence of the counter voltage on the shape of the response function. (orig./HP) [de

  8. Computer simulation of gain fluctuations in proportional counters

    International Nuclear Information System (INIS)

    Demir, Nelgun; Tapan, . Ilhan

    2004-01-01

    A computer simulation code has been developed in order to examine the fluctuation in gas amplification in wire proportional counters which are common in detector applications in particle physics experiments. The magnitude of the variance in the gain dominates the statistical portion of the energy resolution. In order to compare simulation and experimental results, the gain and its variation has been calculated numerically for the well known Aleph Inner Tracking Detector geometry. The results show that the bias voltage has a strong influence on the variance in the gain. The simulation calculations are in good agreement with experimental results. (authors)

  9. Proportional counter with a uniform electric field in the zone of avalanche multiplication of electrons

    International Nuclear Information System (INIS)

    Marzec, J.; Pawlowski, Z.

    1982-01-01

    The work describes the construction of a proportional counter with a uniform electric field in the zone of avalanche multiplication of electrons. It has been shown that in this counter filled with Penning's mixtures Ne+Ar+CO 2 , Ne+CH 4 and Ar+C 2 H 2 , much higher resolutions are obtained than in typical cylindrical counters. In the counter described filled with a mixture of Ne+1%CH 4 , a resolution of fwhm=10.5% has been obtained for E=5.9 keV. (orig.)

  10. Absolute calibration of TFTR helium proportional counters

    International Nuclear Information System (INIS)

    Strachan, J.D.; Diesso, M.; Jassby, D.; Johnson, L.; McCauley, S.; Munsat, T.; Roquemore, A.L.; Loughlin, M.

    1995-06-01

    The TFTR helium proportional counters are located in the central five (5) channels of the TFTR multichannel neutron collimator. These detectors were absolutely calibrated using a 14 MeV neutron generator positioned at the horizontal midplane of the TFTR vacuum vessel. The neutron generator position was scanned in centimeter steps to determine the collimator aperture width to 14 MeV neutrons and the absolute sensitivity of each channel. Neutron profiles were measured for TFTR plasmas with time resolution between 5 msec and 50 msec depending upon count rates. The He detectors were used to measure the burnup of 1 MeV tritons in deuterium plasmas, the transport of tritium in trace tritium experiments, and the residual tritium levels in plasmas following 50:50 DT experiments

  11. Proportional counter with a uniform electric field in the zone of avalanche multiplication of electrons

    Energy Technology Data Exchange (ETDEWEB)

    Marzec, J.; Pawlowski, Z. (Politechnika Warszawska (Poland). Inst. Radioelektroniki)

    1982-09-15

    The work describes the construction of a proportional counter with a uniform electric field in the zone of avalanche multiplication of electrons. It has been shown that in this counter filled with Penning's mixtures Ne+Ar+CO/sub 2/, Ne+CH/sub 4/ and Ar+C/sub 2/H/sub 2/, much higher resolutions are obtained than in typical cylindrical counters. In the counter described filled with a mixture of Ne+1%CH/sub 4/, a resolution of fwhm=10.5% has been obtained for E=5.9 keV.

  12. CWRU multiwire proportional counter readout system

    International Nuclear Information System (INIS)

    Bevington, P.R.; Leskovec, R.A.

    1977-01-01

    An electronic system is described which translates pulses from individual wires of multiwire proportional counters into binary addresses indicating the location of the wires in the chambers. The system combines a fast (<100 ns) serial scan of an event buffer with parallel encoding to provide fast transfer of addresses (250 ns per hit). The buffer has provision for disabling the input less than 40 ns after detection of an event to suppress recording of multiple hits caused by individual events. The encoder can digitize the address of every hit encountered or just the first addresses of contiguous hits. The system includes a coincidence trigger for determining whether timing criteria have been satisfied between chambers and with external devices. Events which do not meet the coincidence criteria are typically reset within 400 ns. The addresses are transferred to a computer interface through CAMAC modules. Multiple buffering permits further data acquisition during CAMAC transfer cycles. (Auth.)

  13. Fabrication of preamplifier for proportional counter

    International Nuclear Information System (INIS)

    Lotfi, Y.; Yazdanpanah, M.; Talebi, B.; Mohammadi, A.; Etaati, Gh.

    2002-01-01

    We have tried to describe techniques of preamplifier fabrication for proportional counter. At first electronic circuit of preamplifier has been analyzed by means of Or cad 9.1. Then we assembled the circuit. Thereafter essential and standard parameters of preamplifier has been measured and compared with foreign made one, according to IEEE standard method. (IEEE Std 301-1988) Specification for our preamplifier is: 1. Rise time of output plus: 25 nsec. 2. Fall time of output pulse: 50μ sec. 3. Charge sensitive: 46.3 mV/pc. 4. Average noise: 500 ion pair (rms) 5. Count R ate L imit: 9.14*10 10 Count/sec. 6. Resolution: %1.3 7. Spectrum of Bf3 detector to 300μ Ci Am-Be source for this preamplifier is the same as foreign one. On the Whole comparison of this preamplifier with the foreign one shows that their parameters similarity is about %95

  14. Set-up of proportional counter L2 for 14C measurements with improved precision

    International Nuclear Information System (INIS)

    Goslar, T.; Pazdur, A.; Pazdur, M.F.; Walanus, A.; Zastawny, A.

    1990-01-01

    Radiocarbon dating with improved precision denotes determination of conventional radiocarbon dates with accuracy equal to ca ± 25 yr. The paper presents some fundamental data concerning construction and design of the proportional counter L2, the results of calibration of the counter, including detailed information on changes of the background counting rate. The counter L2 enables dating of samples up to 50 000 yr. For samples younger than 3000 yr the error of dating is equal to ca ± 25 yr. 4 figs., 1 tab., 9 refs. (author)

  15. Risetime discrimination applied to pressurized Xe gas proportional counter for hard x-ray detection

    International Nuclear Information System (INIS)

    Fujii, Masami; Doi, Kosei

    1978-01-01

    A high pressure Xe proportional counter has been developed for hard X-ray observation. This counter has better energy-resolving power than a NaI scintillation counter, and the realization of large area is relatively easy. This counter is constructed with a cylindrical aluminum tube, and this tube can be used at 40 atmospheric pressure. The detection efficiency curves were obtained in relation to gas pressure. It is necessary to reduce impurities in the Xe gas to increase the energy-resolving power of the counter. The increase of gas pressure made the resolving power worse. The characteristics of the counter were stable for at least a few months. The wave form discrimination was applied to reduce the background signals such as pulses caused by charged particles and gamma-ray. This method has been used for normal pressure counter, and in the present study, it was applied for the high pressure counter. It was found that the discrimination method was able to be applied to this case. (Kato, T.)

  16. Determination of optimum shape and dimensions of anode high-voltage isolators for gaseous proportional counters

    International Nuclear Information System (INIS)

    Jelen, K.; Jagusztyn, W.

    1975-01-01

    The influence of the shape and dimensions of the high-voltage anode-to-cathods isolator on the regularity of the electrostatic field distribution along the anode of a cylindrical gaseous proportional counter is studied. For a counter of fixed dimensions, the length and diameter of the glass isolators were optimized to disrupt as little as possible the regularity of the field distribution in the active volume of the counter. Results of calculations are in agreement with experimental data. The obtained results provide a basis for obtaining a correct ratio of the active volume of the counter to its total volume. (author)

  17. Low-pressure, multistep, multiwire proportional counter for the time-of-flight isochronous spectrometer

    International Nuclear Information System (INIS)

    Vieira, D.J.

    1985-01-01

    A low-pressure, multistep, multiwire proportional counter (MSMWPC) has been developed for the characterization and testing of the time-of-flight isochronous (TOFI) spectrometer and its associated secondary-beam transport line. This type of counter was selected because of its high sensitivity, large dynamic range, and good position (0.2 mm FWHM) and timing (180 ps FWHM) resolution. Furthermore, because the counter operates at low gas pressures (1-10 torr) and high electric-field strengths, which enable short collection times, it can be used as a transmission counter with thin gas-isolation windows and it can operate at high counting rates. Here the authors discuss the basic operating principle of the MSMWPC, describe the technical details of the detector and signal processing, and report on the performance they have measured for alpha particles and fission fragments

  18. A multiwire proportional counter for very high counting rates

    International Nuclear Information System (INIS)

    Barbosa, A.F.; Guedes, G.P.; Tamura, E.; Pepe, I.M.; Oliveira, N.B.

    1997-12-01

    Preliminary measurements in a proportional counter with two independently counting wires showed that counting rates up to 10 6 counts/s per wire can be reached without critical loss in the true versus measured linearity relation. Results obtained with a detector containing 30 active wires (2 mm pitch) are presented. To each wire is associated a fast pre-amplifier and a discriminator channel. Global counting rates in excess to 10 7 events/s are reported. Data acquisition systems are described for 1D (real time) and 2D (off-line) position sensitive detection systems. (author)

  19. A pill-box design, flow type, gas scintillation proportional counter

    International Nuclear Information System (INIS)

    Garg, S.P.; Sharma, R.C.; Bhati, S.; Somasundaram, S.

    1982-01-01

    A gas scintillation proportional counter of 'pill-box' design operated with argon + 2.5% nitrogen gas in continuous flow, has been developed. An energy resolution of 1.6% is obtained for 239 Pu α-particles emitted from a mixed nuclide source of 239 Pu- 241 Am- 244 Cm and injected into the counter parallel to the anode. The risetime of the scintillation pulse is found to be less than 0.5 μs. Measurements have been made of charge and light gain factors as a function of anode voltage. It is found that for a given anode voltage, the scintillation pulse amplitude increases sharply with the addition of nitrogen to argon and reaches a maximum at about 2.5% and then decreases slowly, whereas the charge pulse amplitude reduces monotonically. Nitrogen improvement factors with the addition of 2.5% nitrogen to argon are found to be different for two photomultipliers with different photocathode responses. The improvement in energy resolution as a result of addition of nitrogen to argon is discussed. Comments are made on the intrinsic energy resolution capabilities of such a counter. (orig.)

  20. The suppression of destructive sparks in parallel plate proportional counters

    Energy Technology Data Exchange (ETDEWEB)

    Cockshott, R.A.; Mason, I.M.

    1984-02-01

    The authors find that high energy background events produce localised sparks in parallel plate counters when operated in the proportional mode. These sparks increase dead-time and lead to degradation ranging from electrode damage to spurious pulsing and continuous breakdown. The problem is particularly serious in low energy photon detectors for X-ray astronomy which are required to have lifetimes of several years in the high radiation environment of space. For the parallel plate imaging detector developed for the European X-ray Observatory Satellite (EXOSAT) they investigate quantitatively the spark thresholds, spark rates and degradation processes. They discuss the spark mechanism, pointing out differences from the situation in spark chambers and counters. They show that the time profile of the sparks allows them to devise a spark suppression system which reduces the degradation rate by a factor of ''200.

  1. Response matrix of a multisphere neutron spectrometer with an 3 He proportional counter

    International Nuclear Information System (INIS)

    Vega C, H.R.; Manzanares A, E.; Hernandez D, V.M.; Mercado S, G.A.

    2005-01-01

    The response matrix of a Bonner sphere spectrometer was calculated by use of the MCNP code. As thermal neutron counter, the spectrometer has a 3.2 cm-diameter 3 He-filled proportional counter which is located at the center of a set of polyethylene spheres. The response was calculated for 0, 3, 5, 6, 8, 10, 12, and 16 inches-diameter polyethylene spheres for neutrons whose energy goes from 10 -9 to 20 MeV. The response matrix was compared with a set of responses measured with several monoenergetic neutron sources. In this comparison the calculated matrix agrees with the experimental results. The matrix was also compared with the response matrix calculated for the PTB C spectrometer. Even though that calculation was carried out using a detailed model to describe the proportional counter; both matrices do agree, but small differences are observed in the bare case because of the difference in the model used during calculations. Other differences are in some spheres for 14.8 and 20 MeV neutrons, probably due to the differences in the cross sections used during both calculations. (Author) 28 refs., 1 tab., 6 figs

  2. The miniaturized proportional counter HD-2(Fe)/(Si) for the GALLEX solar neutrino experiment

    Energy Technology Data Exchange (ETDEWEB)

    Wink, R.; Anselmann, P.; Doerflinger, D.; Hampel, W.; Heusser, G.; Kirsten, T.; Moegel, P.; Pernicka, E.; Plaga, R.; Schlosser, C. (Max Planck Inst. fuer Kernphysik, Heidelberg (Germany))

    1993-06-01

    The miniaturized proportional counters used for the detection of [sup 71]Ge in the solar neutrino project GALLEX are characterized. We also report on the construction techniques applied to build these counters and to achieve the described performance. A very low counting background is achieved by, among other things, careful selection of the materials used for construction. The total [sup 71]Ge detection efficiency after applying cuts to reduce the background is about 66%. (orig.).

  3. Calibration methodology for proportional counters applied to yield measurements of a neutron burst

    International Nuclear Information System (INIS)

    Tarifeño-Saldivia, Ariel; Pavez, Cristian; Soto, Leopoldo; Mayer, Roberto E

    2015-01-01

    This work introduces a methodology for the yield measurement of a neutron burst using neutron proportional counters. The methodology is based on the calibration of the counter in pulse mode, and the use of a statistical model to estimate the number of detected events from the accumulated charge resulting from detection of the burst of neutrons. An improvement of more than one order of magnitude in the accuracy of a paraffin wax moderated 3 He-filled tube is obtained by using this methodology with respect to previous calibration methods. (paper)

  4. Proton recoil spectra in spherical proportional counters calculated with finite element and Monte Carlo methods

    Energy Technology Data Exchange (ETDEWEB)

    Benmosbah, M. [Laboratoire de Chimie Physique et Rayonnement Alain Chambaudet, UMR CEA E4, Universite de Franche-Comte, 16 route de Gray, 25030 Besancon Cedex (France); Groetz, J.E. [Laboratoire de Chimie Physique et Rayonnement Alain Chambaudet, UMR CEA E4, Universite de Franche-Comte, 16 route de Gray, 25030 Besancon Cedex (France)], E-mail: jegroetz@univ-fcomte.fr; Crovisier, P. [Service de Protection contre les Rayonnements, CEA Valduc, 21120 Is/Tille (France); Asselineau, B. [Laboratoire de Metrologie et de Dosimetrie des Neutrons, IRSN, Cadarache BP3, 13115 St Paul-lez-Durance (France); Truffert, H.; Cadiou, A. [AREVA NC, Etablissement de la Hague, DQSSE/PR/E/D, 50444 Beaumont-Hague Cedex (France)

    2008-08-11

    Proton recoil spectra were calculated for various spherical proportional counters using Monte Carlo simulation combined with the finite element method. Electric field lines and strength were calculated by defining an appropriate mesh and solving the Laplace equation with the associated boundary conditions, taking into account the geometry of every counter. Thus, different regions were defined in the counter with various coefficients for the energy deposition in the Monte Carlo transport code MCNPX. Results from the calculations are in good agreement with measurements for three different gas pressures at various neutron energies.

  5. A versatile gas-flow proportional counter for Moessbauer spectroscopy

    Energy Technology Data Exchange (ETDEWEB)

    Bibicu, I., E-mail: bibicu@infim.ro [National Institute for Materials Physics (Romania); Nicolescu, G. [IFIN-HH, National Institute of Physics and Nuclear Engineering (Romania); Cretu, C. [Transylvania University, Physics Department (Romania)

    2009-07-15

    This article presents a versatile gas-flow proportional counter for surface and transmission Moessbauer spectroscopy, suitable for studies with {sup 57}Fe, {sup 119}Sn and {sup 151}Eu isotopes. The main advantages obtained by new design are: (1) the height of the detection volume can be changed in large limits from 0 to 38 mm, (2) the detection volume can be choose symmetrical or not in respect with anode plan, (3) the anode replacement is easily (4) and different anode configuration can be used. The characteristics of the detector, operating at room temperature, are reported.

  6. A multiwire proportional counter for very high counting rates

    Energy Technology Data Exchange (ETDEWEB)

    Barbosa, A F; Guedes, G P [Centro Brasileiro de Pesquisas Fisicas (CBPF), Rio de Janeiro, RJ (Brazil); Tamura, E [Laboratorio Nacional de Luz Sincrotron (LNLS), Campinas, SP (Brazil); Pepe, I M; Oliveira, N B [Bahia Univ., Salvador, BA (Brazil). Inst. de Fisica

    1997-12-01

    Preliminary measurements in a proportional counter with two independently counting wires showed that counting rates up to 10{sup 6} counts/s per wire can be reached without critical loss in the true versus measured linearity relation. Results obtained with a detector containing 30 active wires (2 mm pitch) are presented. To each wire is associated a fast pre-amplifier and a discriminator channel. Global counting rates in excess to 10{sup 7} events/s are reported. Data acquisition systems are described for 1D (real time) and 2D (off-line) position sensitive detection systems. (author) 13 refs., 6 figs.

  7. Quality measurement by proportional counter with B

    International Nuclear Information System (INIS)

    Onizuka, Yoshihiko; Endo, Satoru; Tanaka, Kenichi

    2005-01-01

    The dosimetry of air and the tissue-equivalent phantom made of acryl are carried out by the tissue-equivalent proportional counter (TEPC) and TEPC with wall contained B, and both results were compared. The changes of quality with distance from the beam center are determined by the frequency mean renewal energy y F (y)and the dose mean renewal energy y D (y) as indicators of quality. Both y F (y)and y D (y) of tissue-equivalent phantom are larger than air, but very large change was not observed in all distance. The dose rate is determined by y D (y), the number of events and measurement time. Change of dose rate was larger than the change of quality. The maximum value of dose rate depended on γray and neutron beam showed at the point 2 cm away from the center. (S.Y.)

  8. A helium-3 proportional counter technique for estimating fast and intermediate neutrons

    International Nuclear Information System (INIS)

    Kosako, Toshiso; Nakazawa, Masaharu; Sekiguchi, Akira; Wakabayashi, Hiroaki.

    1976-11-01

    3 He proportional counter was employed to determine the fast and intermediate neutron spectra of wide energy region. The mixed gas ( 3 He, Kr) type counter response and the spectrum unfolding code were prepared and applied to some neutron fields. The counter response calculation was performed by using the Monte Carlo code, paying regards to dealing of the particle range calculation of the mixed gas. An experiment was carried out by using the van de Graaff accelerator to check the response function. The spectrum unfolding code was prepared so that it may have the function of automatic evaluation of the higher energy spectrum's effect to the pulse hight distribution of the lower energy region. The neutron spectra of the various neutron fields were measured and compared with the calculations such as the discrete ordinate Sn calculations. It became clear that the technique developed here can be applied to the practical use in the neutron energy range from about 150 KeV to 5 MeV. (auth.)

  9. Interfacing a gas proportional counter with a mass spectrometer: Simultaneous display of GC/MS and radiocarbon data

    International Nuclear Information System (INIS)

    Peterson, G.S.; Laemmerhirt, D.F.; Weaver, A.

    1985-01-01

    To facilitate the location of pesticides and monitor their metabolism in environmental and biological systems, carbon-14 labelling of the parent compound is used. Detection of the radiolabel is achieved using a gas proportional counter, while identification of the labelled components is most easily accomplished with mass spectrometry. However, when these two operations are performed separately, correlation of the information is awkward, at best. Since each is a destructive detector, simultaneous monitoring of the outposts requires an effluent splitter. The complete system consists of a variable splitter, which allows control of the ratio of the GC effluent to the two instruments, and signal processing circuitry for simultaneous recording and storage of radiocarbon and mass spectral data. Modifications to a Finnigan GC/MS and Gas Proportional Counter included a high temperature GC effluent splitter with glass-lined connecting tubing, and a data interface, including analog to digital and serial to parallel conversions with optical isolation between the gas proportional counter and the computer. The splitter restricted the flow to the mass spectrometer, preventing flow completely in the closed position. The split was adjusted to maximize flow to the mass spectrometer using the vacuum as a rough guide (1.0 x 10 -5 torr in EI, 7.5 x 10 -5 torr in CI). A heated transfer line between the transfer oven and gas proportional counter prevented condensation of eluting components prior to radiocarbon detection

  10. A comparison between the measurements of Kr-85 in environmental samples by liquid scintillation and proportional counters

    International Nuclear Information System (INIS)

    Heras Iniquez, M.C.; Perez Garcia, M.M.

    1983-01-01

    The most used methods for the measurement of Kr-81 beta-activity after their concentration and aisolation are the liquid scintillation counting and the proportional counter. In this work the beta activity of concentrated and aisolated Kr-85 samples measured in collaboration with the Max-Planck Institut fur Kernphyslk, Aussenstelle Freiburg. Samples taken both In Madrid and Frelburg are measured by proportional counters in the Max-Planck lnstitut, Freibury and by liquid scintillation counting in JEN, Madrid. The comparison of both measurements do not show appreciable discrepancy between the results obtained to both techniques. (Author)

  11. Comprehensive applications of the gas flow proportional counters for radiological surveillance

    International Nuclear Information System (INIS)

    Babu, D.A.R.; Raman, Anand; Ashokkumar, P.; Sharma, D.N.

    2008-01-01

    Gas Flow Proportional Counters (GFPC) have been developed indigenously for various radiation protection applications. These detectors can be fabricated for 2 inches diameter filter paper sample counting applications to large area (∼1500 cm 2 ) detectors for surface contamination applications. Thin entrance windows allow non penetrating type of radiations like alpha and low energy beta particles, Efficiencies (for alpha and beta radiations) are comparable to conventional detectors used to measure these radiations. Poor gamma efficiency ( 2 /γ ratio, a high figure of merit and enables efficient gamma background rejection. These detectors are quite suitable for Indian environmental conditions. Three systems have been developed and successfully incorporated in to the radiation surveillance program at various nuclear facilities. The systems based on GFPC detectors include: a) Multiple sample gross alpha counting system; b) Laundry monitoring system; c) Alpha hand contamination monitoring system. The first of these enables simultaneous gross alpha counting of five air activity filter paper samples. The area of the detector surface is optimized to cover the 2 inches sized filter paper samples routinely used for the purpose. Five numbers of GFPC 's are arranged sequentially coupled to five individual amplifiers - micro controller modules to process the signal from the five counters. The laundry monitor which is micro controller based system consists of four large area multiwire GFPC detectors (700 cm 2 sensitive area) used to monitor alpha contamination of decontaminated laundry, Each detector uses a charge sensitive preamplifier coupled to I 2 C counter. The alpha hand monitoring system consists of four large area multiwire gas flow proportional detectors (330 cm 2 sensitive area each). A micro controller-based module is employed to initiate the counting process automatically when the hands are inserted in to the suitably designed window slots and provides audio and

  12. Direct measurement of gaseous activities by diffusion-in long proportional counter method

    International Nuclear Information System (INIS)

    Yoshida, M.; Yamamoto, T.; Wu, Y.; Aratani, T.; Uritani, A.; Mori, C.

    1993-01-01

    Direct measurement of gaseous activities by the diffusion-in long proportional counter method (DLPC method) was studied. The measuring time without end effect was estimated by observing the behavior of 37 Ar in the counter and was long enough to carry out the accurate activity measurement. The correction for wall effect was also examined on the basis of the measured and calculated correction factors. Among the tested gases of methane, P10 gas and propane, P10 gas was made clear to be a suitable counting gas for the DLPC method because of good diffusion properties and small wall effect. This method is quite effective for standardization of gaseous activities used for tracer experiments and calibration works of radioactive gas monitoring instruments. (orig.)

  13. Miniature proportional counter for compression measurements of laser-fusion targets

    International Nuclear Information System (INIS)

    Lane, S.M.; Dellis, J.H.; Bennett, C.K.; Campbell, E.M.

    1981-10-01

    Direct drive laser fusion targets consisting of DT gas encapsulated in glass microshells produce 14.1 MeV neutrons that can interact with silicon-28 nuclei in the glass to produce a 2.2 minute aluminum-28 activity. From the number of 28 Al nuclei created and the neutron yield, the compressed glass areal density can be found. To determine the number of activated atoms created, we collect approximately one-half of the target debris on a thin metal foil which is transferred to our beta-gamma coincidence detector. This detector consists of a 25 cm x 25 cm NaI(Tl) crystal having a 5 cm x 15 cm well. We have recently built a miniature proportional counter that fits into this well and is used to detect beta particles. It is constructed of .025 cm thick copper and has nine separate chambers through which methane flows. The coincidence background is 0.14 cpm and the measured beta efficiency is 45%. We are now building a .0125 cm thick counter made of aluminum having a predicted efficiency of > 90%

  14. Desarrollo de una hoja excel para metaanálisis de comparaciones indirectas y mixtas

    Directory of Open Access Journals (Sweden)

    Aurelio Tobías

    2014-01-01

    Full Text Available En investigación clínica, el meta análisis ha servido generalmente para evaluar la eficacia y la seguridad de un tratamiento a través de la comparación con un único comparador. Las comparaciones indirectas, a través del método de Bucher, permiten combinar datos procedentes de estudios primarios de una forma sencilla cuando la información para las comparaciones directas es limitada o inexistente. Las comparaciones mixtas permiten combinar las estimaciones procedentes de comparaciones directas e indirectas, aumentando el poder estadístico. En la actualidad, es necesario el desarrollo de aplicaciones informáticas para el cálculo de meta análisis de comparaciones indirectas y mixtas. Por este motivo, se ha desarrollado una hoja de cálculo con Microsoft Office Excel para el cálculo de comparaciones indirectas y mixtas, de uso sencillo para investigadores clínicos interesados en revisiones sistemáticas con meta análisis, pero no familiarizados con el uso de paquetes estadísticos más avanzados. La utilización de esta hoja de cálculo para las comparaciones indirectas y mixtas puede ser de gran utilidad en epidemiología clínica, con el fin de extender el conocimiento proporcionado por el metaanálisis tradicional cuando la evidencia de las comparaciones directas es limitada o inexistente.

  15. Numerical modelling of tissue-equivalent proportional counters

    International Nuclear Information System (INIS)

    Segur, P.; Colautti, P.

    1995-01-01

    In this paper a survey is given of the various numerical techniques employed to study the transport of ionising particles inside a TEPC. The first part is devoted to the description of the general concept of particle transport calculations. Thereafter, the different methods available to study transport phenomena and energy deposition in the sensitive volume and in counter walls are described. Finally, the basic ionisation mechanisms which may occur in a counter are described, and the non-equilibrium phenomena which play an important role mainly for counters that are to be used in measurements at the nanodosemeter level are studied. (author)

  16. Development of new type boron-coating proportional counter and its experimental investigation and simulation calculation

    International Nuclear Information System (INIS)

    Zhang Zixia; Wei Zhiyong; Fang Meihua; Qiang Peng; Zhu Li; Chen Guoyun

    2015-01-01

    Three materials wherein suitable proportion of isotope enriched 10 B powder, 1, 2-ethylene dichloride and formvar resin were blended to make 10 B neutron sensitive coating by oneself. A new type proportional counter that coated with 10 B neutron sensitive coating was made. Furthermore, in order to increase the character and quality of the neutron detector, a set of 14 annulus epoxy sheets which were sided with 10 B film were placed in the tube. A series performance tests were done by 241 Am-Be neutron source. The tests of 3.7 × 10 9 Bq 211 Am-Be neutron source show that the plateau length of detector is 150 V from 750 V to 900 V, while the plateau slope is 8.2%/100 V. When the working voltage is 800 V, the count rate of new type boron-coating proportional counter is 50 s -1 . The level of sensitivity is 0.71 cm 2 . Compared with the detector only coated with 10 B film in the inner walls of detector, neutron sensitivity area of the new detector increases to 3.15 times. The results show that the plateau length increases from 80 V to 150 V, and the plateau slope is improved from 12.4%/100 V to 7.58%/100 V, while the neutron sensitivity increases to 2.63 times. Using Geant4 software based on Monte Carlo method, this paper presented the response and detection efficiency of new type boron-coating proportional counter, which was covered with φ55 mm × 250 mm cylinder high density polyethylene moderator material. The simulation results of Geant4 are in agreement with the results of 241 Am-Be neutron source experiment. It shows the reliability of simulation application. (authors)

  17. Demand-type gas supply system for rocket borne thin-window proportional counters

    Science.gov (United States)

    Acton, L. W.; Caravalho, R.; Catura, R. C.; Joki, E. G.

    1977-01-01

    A simple closed loop control system has been developed to maintain the gas pressure in thin-window proportional counters during rocket flights. This system permits convenient external control of detector pressure and system flushing rate. The control system is activated at launch with the sealing of a reference volume at the existing system pressure. Inflight control to plus or minus 2 torr at a working pressure of 760 torr has been achieved on six rocket flights.

  18. {sup 10}B multi-grid proportional gas counters for large area thermal neutron detectors

    Energy Technology Data Exchange (ETDEWEB)

    Andersen, K. [ESS, P.O. Box 176, SE-221 00 Lund (Sweden); Bigault, T. [ILL, BP 156, 6, rue Jules Horowitz, 38042 Grenoble Cedex 9 (France); Birch, J. [Linköping University, SE-581, 83 Linköping (Sweden); Buffet, J. C.; Correa, J. [ILL, BP 156, 6, rue Jules Horowitz, 38042 Grenoble Cedex 9 (France); Hall-Wilton, R. [ESS, P.O. Box 176, SE-221 00 Lund (Sweden); Hultman, L. [Linköping University, SE-581, 83 Linköping (Sweden); Höglund, C. [ESS, P.O. Box 176, SE-221 00 Lund (Sweden); Linköping University, SE-581, 83 Linköping (Sweden); Guérard, B., E-mail: guerard@ill.fr [ILL, BP 156, 6, rue Jules Horowitz, 38042 Grenoble Cedex 9 (France); Jensen, J. [Linköping University, SE-581, 83 Linköping (Sweden); Khaplanov, A. [ILL, BP 156, 6, rue Jules Horowitz, 38042 Grenoble Cedex 9 (France); ESS, P.O. Box 176, SE-221 00 Lund (Sweden); Kirstein, O. [Linköping University, SE-581, 83 Linköping (Sweden); Piscitelli, F.; Van Esch, P. [ILL, BP 156, 6, rue Jules Horowitz, 38042 Grenoble Cedex 9 (France); Vettier, C. [ESS, P.O. Box 176, SE-221 00 Lund (Sweden)

    2013-08-21

    {sup 3}He was a popular material in neutrons detectors until its availability dropped drastically in 2008. The development of techniques based on alternative convertors is now of high priority for neutron research institutes. Thin films of {sup 10}B or {sup 10}B{sub 4}C have been used in gas proportional counters to detect neutrons, but until now, only for small or medium sensitive area. We present here the multi-grid design, introduced at the ILL and developed in collaboration with ESS for LAN (large area neutron) detectors. Typically thirty {sup 10}B{sub 4}C films of 1 μm thickness are used to convert neutrons into ionizing particles which are subsequently detected in a proportional gas counter. The principle and the fabrication of the multi-grid are described and some preliminary results obtained with a prototype of 200 cm×8 cm are reported; a detection efficiency of 48% has been measured at 2.5 Å with a monochromatic neutron beam line, showing the good potential of this new technique.

  19. Calibration of an ultra-low-background proportional counter for measuring 37Ar

    International Nuclear Information System (INIS)

    Seifert, A.; Aalseth, C. E.; Bonicalzi, R. M.; Bowyer, T. W.; Day, A. R.; Fuller, E. S.; Haas, D. A.; Hayes, J. C.; Hoppe, E. W.; Humble, P. H.; Keillor, M. E.; LaFerriere, B. D.; Mace, E. K.; McIntyre, J. I.; Merriman, J. H.; Miley, H. S.; Myers, A. W.; Orrell, J. L.; Overman, C. T.; Panisko, M. E.

    2013-01-01

    An ultra-low-background proportional counter design has been developed at Pacific Northwest National Laboratory (PNNL) using clean materials, primarily electro-chemically-purified copper. This detector, along with an ultra-low-background counting system (ULBCS), was developed to complement a new shallow underground laboratory (30 meters water-equivalent) at PNNL. The ULBCS design includes passive neutron and gamma shielding, along with an active cosmic-veto system. This system provides a capability for making ultra-sensitive measurements to support applications like age-dating soil hydrocarbons with 14 C/ 3 H, age-dating of groundwater with 39 Ar, and soil-gas assay for 37 Ar to support On-Site Inspection (OSI). On-Site Inspection is a key component of the verification regime for the Comprehensive Nuclear-Test-Ban Treaty (CTBT). Measurements of radionuclides created by an underground nuclear explosion are valuable signatures of a Treaty violation. For OSI, the 35-day half-life of 37 Ar, produced from neutron interactions with calcium in soil, provides both high specific activity and sufficient time for inspection before decay limits sensitivity. This work describes the calibration techniques and analysis methods developed to enable quantitative measurements of 37 Ar samples over a broad range of proportional counter operating pressures. These efforts, along with parallel work in progress on gas chemistry separation, are expected to provide a significant new capability for 37 Ar soil gas background studies

  20. Use of the helium-3 proportional counter for neutron spectrometry

    International Nuclear Information System (INIS)

    Vialettes, H.; Le Thanh, P.

    1967-01-01

    Up to now, two methods have been mainly used for neutron spectrometry near nuclear installations: - photographic emulsion spectrometry - the so-called, 'multisphere' technique spectrometry. The first method, which is fairly difficult to apply, has a threshold energy of about 500 keV; this is a big disadvantage for an apparatus which has to be used for spectrometry around nuclear installations where the neutron radiation is very much degraded energetically. The second method does not suffer from this disadvantage but the results which it yields are only approximate. In order to extend the energy range of the neutron spectra studied with sufficient accuracy the use of a helium-3 proportional counter has been considered. This report presents the principles of operation of the helium-3 spectrometer, and the calculation methods which make it possible to take into account the two main effects tending to deform the spectra obtained: - energy absorption by the walls of the counter, - energy loss of the incident neutrons due to elastic collisions with helium-3 nuclei. As an example of the application, the shape of the neutron spectrum emitted by a polonium-lithium source is given; the results obtained are in excellent agreement with theoretical predictions. (authors) [fr

  1. Output pulse-shapes of position-sensitive proportional counters using high resistance single wire

    International Nuclear Information System (INIS)

    Iwatani, Kazuo; Nishiyama, Fumitaka; Hasai, Hiromi

    1980-01-01

    The measurements and model analysis of the output pulse-shapes from a single wire proportional counter (SWPC) which has a high resistance anode are described. The characteristics of the observed pulse-shapes are determined by only one parameter which is a function of anode resistance and load resistance and they are reproduced by a simple model. Using this model, the methods for position read-out are discussed in a systematical way. (author)

  2. The Rutherford Appleton Laboratory's Mark I Multiwire Proportional Counter positron camera

    International Nuclear Information System (INIS)

    Bateman, J.E.; Connolly, J.F.; Stephenson, R.; Tappern, G.J.; Flesher, A.C.

    1983-01-01

    A small model of a proposed large aperture positron camera has been developed at Rutherford Appleton Laboratory. Based on Multiwire Proportional Counter technology it uses lead foil cathodes which function simultaneously as converters for the 511 keV gamma rays and readout electrodes for a delay line readout system. The detectors have been built up into a portable imaging system complete with a dedicated computer for data taking, processing and display. A complete hardware system and sufficient software was provided to permit hospital based colleagues to generate useful images easily. A complete description of the system is given with performance figures and some of the images obtained are presented. (author)

  3. Annular shape silver lined proportional counter for on-line pulsed neutron yield measurement

    International Nuclear Information System (INIS)

    Dighe, P.M.; Das, D.

    2015-01-01

    An annular shape silver lined proportional counter is developed to measure pulsed neutron radiation. The detector has 314 mm overall length and 235 mm overall diameter. The central cavity of 150 mm diameter and 200 mm length is used for placing the neutron source. Because of annular shape the detector covers >3π solid angle of the source. The detector has all welded construction. The detector is developed in two halves for easy mounting and demounting. Each half is an independent detector. Both the halves together give single neutron pulse calibration constant of 4.5×10 4 neutrons/shot count. The detector operates in proportional mode which gives enhanced working conditions in terms of dead time and operating range compared to Geiger Muller based neutron detectors

  4. Investigations of X-ray response of single wire anode Ar-N2 flow type gas scintillation proportional counters

    International Nuclear Information System (INIS)

    Garg, S.P.; Sharma, R.C.

    1984-01-01

    The X-ray response of single wire anode gas scintillation proportional counters of two different geometries operated with argon+nitrogen gases in continuous flow has been investigated with wire anodes of diameters 25 μm to 1.7 mm. An energy resolution of 19% is obtained for 5.9 keV X-rays entering the counter perpendicular to the anode in pill-box geometry with 25 μm diameter anode. With cylindrical geometry counters energy obtained at 5.9 keV are 18%, 24% and 33% for 50 μm, 0.5 mm and 1.7 mm diameter anodes respectively. An analysis of the observed resolution shows that the contribution from photon counting statistics to the relative variance of scintillation pulses even for X-rays in Ar-N 2 single wire anode gas scintillation proportional counters is small and is not a limiting factor. The energy resolution with thicker anodes, where the contribution from the variance of the charge multiplication factor also has been minimised, is found to deteriorate mainly by the interaction in the scintillation production region. Comments are made on the possibility of improvement in energy resolution by suppression of pulses due to such interactions with the help of the pulse risetime discrimination technique. (orig.)

  5. Electronic system for recording proportional counter rare pulses with the pulse shape analysis

    International Nuclear Information System (INIS)

    Barabanov, I.R.; Gavrin, V.N.; Zakharov, Yu.I.; Tikhonov, A.A.

    1984-01-01

    The anutomated system for recording proportional counter rare pulses is described. The proportional counters are aimed at identification of 37 Ar and H7 1 Gr decays in chemical radiation detectors of solar neutrino. Pulse shape recording by means of a storage oscilloscope and a TV display is performed in the system considered besides two-parametric selection of events (measurement of pulse amplitude in a slow channel and the amplitude of pulse differentiated with time constant of about 10 ns in a parallel fast channel). Pulse discrimination by a front rise rate provides background decrease in the 55 Fe range (5.9 keV) by 6 times; the visual analysis of pulse shapes recorded allows to decrease the background additionally by 25-30%. The background counting rate in the 55 Fe range being equal to 1 pulse per 1.5 days, is obtained when using the installation described above, as well as the passive Pb shield 5 cm thick, and the active shield based on the anticoincidence NaI(Tl) detector with the cathode 5.6 mm in-diameter made of Fe fabircated by zone melting. The installation described allows to reach the background level of 0.6 pulse/day (the total coefficient of background attenuation is 400). Further background decrease is supposed to be provided by installation allocation in the low-noise underground laboratory of the Baksan Neutrino Observatory

  6. Determination of dose equivalent with tissue-equivalent proportional counters

    International Nuclear Information System (INIS)

    Dietze, G.; Schuhmacher, H.; Menzel, H.G.

    1989-01-01

    Low pressure tissue-equivalent proportional counters (TEPC) are instruments based on the cavity chamber principle and provide spectral information on the energy loss of single charged particles crossing the cavity. Hence such detectors measure absorbed dose or kerma and are able to provide estimates on radiation quality. During recent years TEPC based instruments have been developed for radiation protection applications in photon and neutron fields. This was mainly based on the expectation that the energy dependence of their dose equivalent response is smaller than that of other instruments in use. Recently, such instruments have been investigated by intercomparison measurements in various neutron and photon fields. Although their principles of measurements are more closely related to the definition of dose equivalent quantities than those of other existing dosemeters, there are distinct differences and limitations with respect to the irradiation geometry and the determination of the quality factor. The application of such instruments for measuring ambient dose equivalent is discussed. (author)

  7. Low energy recoil detection with a spherical proportional counter

    Science.gov (United States)

    Savvidis, I.; Katsioulas, I.; Eleftheriadis, C.; Giomataris, I.; Papaevangellou, T.

    2018-01-01

    We present results for the detection of low energy nuclear recoils in the keV energy region, from measurements performed with the Spherical Proportional Counter (SPC). An 241Am-9Be fast neutron source is used in order to obtain neutron-nucleus elastic scattering events inside the gaseous volume of the detector. The detector performance in the keV energy region was measured by observing the 5.9 keV line of a 55Fe X-ray source, with energy resolution of 10% (σ). The toolkit GEANT4 was used to simulate the irradiation of the detector by an 241Am-9Be source, while SRIM was used to calculate the Ionization Quenching Factor (IQF), the simulation results are compared with the measurements. The potential of the SPC in low energy recoil detection makes the detector a good candidate for a wide range of applications, including Supernova or reactor neutrino detection and Dark Matter (WIMP) searches (via coherent elastic scattering).

  8. Design and construction techniques for one-meter position sensitive proportional counters of the helical delay line type

    International Nuclear Information System (INIS)

    Orbesen, S.D.; Sherman, J.D.; Flynn, E.R.

    1976-03-01

    A description is given of the techniques involved in the construction of a one-meter long helical proportional counter which produces excellent position accuracy of 1 mm while yielding particle identification through a measurement of energy loss and total energy

  9. Imaging micro-well proportional counters fabricated with masked UV laser ablation

    CERN Document Server

    Deines-Jones, P; Crawford, H; Hunter, S D

    2002-01-01

    The micro-well detector is a gas-proportional counter similar to the CAT (Bartol et al., J. Phys. III 6 (1996) 337) and WELL detectors (Bellazzini et al., Nucl. Instr. and Meth. A 423 (1999) 125). The micro-well is a cylindrical hole formed in the polymer substrate of commercially fabricated copper-clad flexible printed circuit board by UV laser ablation. The micro-wells are drilled at GSFC's UV laser-ablation facility. The cathode is a metal annulus that surrounds the opening of the well. The anode is a metal pad that fills the bottom of the well. Advantages of this topology include intrinsic two-dimensional sensing, thick robust electrodes, and large localized image charge on the cathodes. We have fabricated 5 cmx5 cm micro-well detectors with segmented anodes (1-d) and with both anodes and cathodes segmented (2-d), and have demonstrated: - stable, proportional operation at gas gains in excess of 30,000 in Ar- and Xe-based gases; - FWHM energy resolution of 20% at 6 keV in P-10; - preliminary 1-d spatial re...

  10. Gas-multiplication factor of a proportional counter operated at low temperature described with the Diethorn, Rose-Korff and townsend expressions

    Energy Technology Data Exchange (ETDEWEB)

    Fukumura, Kazuko; Nakanishi, Akio; Kobayashi, Takayuki [Shiga Univ. of Medical Science, Otsu (Japan)

    1996-07-01

    In the present work, the gas-multiplication factor is expressed with the Rose-Korff and Townsend methods as well as with the Diethorn method. A proportional counter with helium or neon works only at low temperature. This is discussed in terms of the number of electrons emitted when an ion is neutralized at the cathode of the counter. (J.P.N.)

  11. A technique for searching for the 2 K capture in 124Xe with a copper proportional counter

    Science.gov (United States)

    Gavrilyuk, Yu. M.; Gangapshev, A. M.; Kazalov, V. V.; Kuzminov, V. V.; Panasenko, S. I.; Ratkevich, S. S.; Tekueva, D. A.; Yakimenko, S. P.

    2015-12-01

    An experimental technique for searching for the 2 K capture in 124Xe with a large low-background copper proportional counter is described. Such an experiment is conducted at the Baksan Neutrino Observatory of the Institute for Nuclear Research of the Russian Academy of Sciences. The experimental setup is located in the Low-Background Deep-Level Laboratory at a depth of 4900 m.w.e., where the flux of muons of cosmic rays is suppressed by a factor of 107 relative to that at the Earth's surface. The setup incorporates a proportional counter and low-background shielding (18 cm of copper, 15 cm of lead, and 8 cm of borated polyethylene). The results of processing the data obtained in 5 months of live measurement time are presented. A new limit on the half-life of 124Xe with respect to the 2 K capture is set at the level of 2.5 × 1021 years.

  12. Multi-level modelling of the response of the ultraminiature proportional counter: gas gain phenomena and pulse height spectra

    International Nuclear Information System (INIS)

    Olko, P.; Moutarde, C.; Segur, P.

    1995-01-01

    The ultraminiature proportional counters, UMC, unique radiation detectors for monitoring high intensity therapy fields, designed by Kliauga and operated at Columbia University (USA), have yielded a number of pulse height distributions for photons, neutrons and ions at simulated diameters of 5-50 nm. Monte Carlo calculations of the gas gain in such a counter questioned the possibility of achieving proportionally at such low simulated diameters. The response of the UMC has now been modelled taking into account both fluctuations of energy deposited in the counter volume and its calculated gas gain. Energy deposition was calculated using the MOCA-14, MOCA-8 and TRION codes, whereby distributions of ionisations d(j) after irradiations with 137 Cs, 15 MeV neutrons and 7 MeV.amu -1 deuterons were obtained. Monte Carlo calculations of electron avalanches in UMC show that the size of the single-electron avalanche P(n) reaching the anode depends strongly on the location of the primary ionisation within the counter volume. Distributions of the size of electron avalanches for higher numbers of primary ionisations, P *j (n), were obtained by successive convolutions of P(n). Finally, the counter response was obtained by weighting P *j (n) over d(j) distributions. On comparing the measured and calculated spectra it was concluded that the previously proposed single-electron peak calibration method might not be valid for the UMC due to the excessive width and overlap of electron avalanche distributions. Better agreement between the measured and calculated spectra is found if broader electron avalanche distributions than those used in the present calculations, are assumed. (author)

  13. Use of the small gas proportional counters for the carbon-14 measurement of very small samples

    International Nuclear Information System (INIS)

    Sayre, E.V.; Harbottle, G.; Stoenner, R.W.; Otlet, R.L.; Evans, G.V.

    1981-01-01

    Two recent developments are: the first is the mass-spectrometric separation of 14 C and 12 C ions, followed by counting of the 14 C, while the second is the extension of conventional proportional counter operation, using CO 2 as counting gas, to very small counters and samples. Although the second method is slow (months of counting time are required for 10 mg of carbon) it does not require operator intervention and many samples may be counted simultaneously. Also, it costs only a fraction of the capital expense of an accelerator installation. The development, construction and operation of suitable small counters are described, and results of three actual dating studies involving milligram scale carbon samples will be given. None of these could have been carried out if conventional, gram-sized samples had been needed. New installations, based on the use of these counters, are under construction or in the planning stages. These are located at Brookhaven Laboratory, the National Bureau of Standards (USA) and Harwell (UK). The Harwell installation, which is in advanced stages of construction, will be described in outline. The main significance of the small-counter method is, that although it will not suffice to measure the smallest (much less than 10 mg) or oldest samples, it will permit existing radiocarbon laboratories to extend their capability considerably, in the direction of smaller samples, at modest expense

  14. Application of the pulse-rise-time discriminator for background noise decreasing in proportional x-ray counters

    International Nuclear Information System (INIS)

    Goganov, D.A.; Guslina, A.G.; Korolev, V.F.; Lozinskij, B.S.; Sklyankin, V.A.

    1977-01-01

    The intrinsic background of commercial rising edge discriminator - based proportional counters has been measured. The block-diagram of the experimental apparatus comprises the detector to be tested, a charge-sensitive amplifier with an amplitude analyzer, a rising edge discriminator (RED) and a scaling device. The rising edges have been analyzed in the range between 0.2 to 0.7 of the pulse amplitude. The RED threshold has been preset to cut off all the edges longer than those of 55 Fe (to register 87% of the 55 Fe quanta). It has been found that by limiting the amplitude discriminator window to +-20% and using a RED the background of commercial counters can be reduced by about an order

  15. An array of low-background 3He proportional counters for theSudbury Neutrino Observatory

    Energy Technology Data Exchange (ETDEWEB)

    Amsbaugh, J.F.; Anaya, J.M.; Banar, J.; Bowles, T.J.; Browne,M.C.; Bullard, T.V.; Burritt, T.H.; Cox-Mobrand, G.A.; Dai, X.; H.Deng,X.; Di Marco, M.; Doe, P.J.; Dragowsky, M.R.; Duba, C.A.; Duncan, F.A.; Earle, E.D.; Elliott, S.R.; Esch, E.-I.; Fergani, H.; Formaggio, J.A.; Fowler, M.M.; Franklin, J.E.; Geissbuehler, P.; Germani, J.V.; Goldschmidt, A.; Guillian, E.; Hallin, A.L.; Harper, G.; Harvey, P.J.; Hazama, R.; Heeger, K.M.; Heise, J.; Hime, A.; Howe, M.A.; Huang, M.; Kormos, L.L.; Kraus, C.; Krauss, C.B.; Law, J.; Lawson, I.T.; Lesko,K.T.; Loach, J.C.; Majerus, S.; Manor, J.; McGee, S.; Miknaitis, K.K.S.; Miller, G.G.; Morissette, B.; Myers, A.; Oblath, N.S.; O' Kee, H.M.; Ollerhead, R.W.; Peeters, S.J.M.; Poon, A.W.P.; Prior, G.; Reitzner,S.D.; Rielage, K.; Robertson, R.G.H.; Skensved, P.; Smith, A.R.; Smith,M.W.E.; Steiger, T.D.; Stonehill,L.C.; Thornewell, P.M.; Tolich, N.; VanDevender, B.A.; VanWechel, T.D.; Wall, B.L.; Tseung, H.W.C.; Wendland,J.; West, N.; Wilhelmy, J.B.; Wilkerson, J.F.; Wouters, J.M.

    2007-02-01

    An array of Neutral-Current Detectors (NCDs) has been builtin order to make a unique measurement of the total active ux of solarneutrinos in the Sudbury Neutrino Observatory (SNO). Data in the thirdphase of the SNO experiment were collected between November 2004 andNovember 2006, after the NCD array was added to improve theneutral-current sensitivity of the SNO detector. This array consisted of36 strings of proportional counters lled with a mixture of 3He and CF4gas capable of detecting the neutrons liberated by the neutrino-deuteronneutral current reaction in the D2O, and four strings lled with a mixtureof 4He and CF4 gas for background measurements. The proportional counterdiameter is 5 cm. The total deployed array length was 398 m. The SNO NCDarray is the lowest-radioactivity large array of proportional countersever produced. This article describes the design, construction,deployment, and characterization of the NCD array, discusses theelectronics and data acquisition system, and considers event signaturesand backgrounds.

  16. Performance tests and comparison of microdosimetric measurements with four tissue-equivalent proportional counters in scanning proton therapy

    Czech Academy of Sciences Publication Activity Database

    Farah, J.; De Saint-Hubert, M.; Mojzeszek, N.; Chiriotti, S.; Gryzinski, M.; Ploc, Ondřej; Trompier, F.; Turek, Karel; Vanhavere, F.; Olko, P.

    2017-01-01

    Roč. 96, JAN (2017), s. 42-52 ISSN 1350-4487 EU Projects: European Commission(XE) 662287 - CONCERT Institutional support: RVO:61389005 Keywords : tissue-equivalent proportional counters * microdosimetry * proton therapy * stray neutrons and prothons Subject RIV: JF - Nuclear Energetics OBOR OECD: Nuclear related engineering Impact factor: 1.442, year: 2016

  17. Identification of relativistic charged particles by means of ionisation energy loss in proportional counters

    International Nuclear Information System (INIS)

    Bateman, J.E.

    1978-12-01

    A method is described of obtaining a useful degree of improvement in the particle discrimination capability of multiwire proportional counters. The normal multiple sampling technique using a suitable bias to combat the small magnitude of the relativistic rise in the ionization energy loss and the wide pulse height distributions obtained in thin gas counters requires a large number of samples for useful discrimination. In the method reported, this number is reduced by suppressing the delta ray contribution to the total charge pulse from the anode wire. A monte carlo model convoluting the 'delta ray suppressed' data from a one sample detector shows that when it is required to separate pions and electrons at 1 GeV/C with a detection efficiency for the electron of 90%, a 'suppressor' circuit can achieve a pion rejection ratio of 250:1 with 82 samples, whereas the truncated mean approach (lowest 70% of samples) requires 100 samples. (UK)

  18. Application of digital waveform processing to position-sensitive proportional counter

    International Nuclear Information System (INIS)

    Takenaka, Yasuto; Uritani, Akira; Mori, Chizuo

    1995-01-01

    In a charge-division type position-sensitive proportional counter (PSPC) with an anode wire of small resistance, a reflected component from an opposite end and thermal noise involved in signals deteriorate the position resolution of the PSPC. A digital waveform processing method was applied to the reduction of these undesirable effects by skillfully utilizing their signal characteristics that can be observed as inversely correlative signals between two-output signals from both sides of the PSPC. The digital waveform processing could improve the position resolution compared to a conventional pulse height processing method with analog filters. When the digital waveform processing was applied to signals of an equivalent circuit simulating the PSPC, the position resolutions defined by the full width at half maximum were improved to about 30% of those of conventional analog pulse processing. In the case of an actual PSPC, the position resolutions by the digital waveform processing were improved by 4-10% as compared with those of conventional pulse height processing. (author)

  19. Construction of a self-supporting tissue-equivalent dividing wall and operational characteristics of a coaxial double-cylindrical tissue-equivalent proportional counter

    International Nuclear Information System (INIS)

    Saion, E.B.; Watt, D.E.

    1994-01-01

    An additional feature incorporated in a coaxial double-cylindrical tissue-equivalent proportional counter, is the presence of a common tissue-equivalent dividing wall between the inner and outer counters of thickness equivalent to the corresponding maximum range of protons at the energy of interest. By appropriate use of an anti-coincidence arrangement with the outer counter, the inner counter could be used to discriminate microdosimetric spectra of neutrons at the desired low energy range from those of the faster neutrons. The construction of an A-150 self-supporting tissue-equivalent dividing wall and an anti-coincidence unit are described. Some operational characteristic tests have been performed to determine the operation of the new microdosimeter. (author)

  20. Determination of the influence of asymmetry of the electric field distribution in gaseous proportional counters on their signal amplitude

    International Nuclear Information System (INIS)

    Jagusztyn, W.

    1976-01-01

    A method is described of establishing the influence of the asymmetry of the electric field distribution in gaseous proportional counters on the amplitude of their voltage signal. A numerical evaluation of this effect demands performing calculations of the electric field in the vicinity of the anode. Using the described method of numerical solution of the Laplace equation in polar coordinates with logarythmically scaled radial dimension, it is possible to achieve the required accuracy. In the calculations of differences in amplitudes of voltage signals, for chosen trajektories of electrons liberated in the process of primary ionization, changes in the gaseous amplification factors and drift velocities of positive ions are taken into account. Experimental results prove the validity of presented theory. The results obtained are accurate enough to be applied to the design of proportional counters of non-cylindrical geometries. (author)

  1. A technique for searching for the 2K capture in {sup 124}Xe with a copper proportional counter

    Energy Technology Data Exchange (ETDEWEB)

    Gavrilyuk, Yu. M.; Gangapshev, A. M.; Kazalov, V. V.; Kuzminov, V. V. [Russian Academy of Sciences, Institute for Nuclear Research (Russian Federation); Panasenko, S. I.; Ratkevich, S. S. [Karazin Kharkiv National University (Ukraine); Tekueva, D. A., E-mail: t.jami.a@mail.ru; Yakimenko, S. P. [Russian Academy of Sciences, Institute for Nuclear Research (Russian Federation)

    2015-12-15

    An experimental technique for searching for the 2K capture in {sup 124}Xe with a large low-background copper proportional counter is described. Such an experiment is conducted at the Baksan Neutrino Observatory of the Institute for Nuclear Research of the Russian Academy of Sciences. The experimental setup is located in the Low-Background Deep-Level Laboratory at a depth of 4900 m.w.e., where the flux of muons of cosmic rays is suppressed by a factor of 10{sup 7} relative to that at the Earth’s surface. The setup incorporates a proportional counter and low-background shielding (18 cm of copper, 15 cm of lead, and 8 cm of borated polyethylene). The results of processing the data obtained in 5 months of live measurement time are presented. A new limit on the half-life of {sup 124}Xe with respect to the 2K capture is set at the level of 2.5 × 10{sup 21} years.

  2. The performance of the curved grid gas proportional scintillation counter in X-ray spectrometry

    International Nuclear Information System (INIS)

    Santos, J.M.F. dos; Bento, A.C.S.S.M.; Conde, C.A.N.

    1994-01-01

    The performance of a curved grid gas proportional scintillation counter filled with xenon at 1100 mbar and having a 25 mm diameter window is evaluated for X-rays in the 1-11 keV energy range. Energy resolutions of 8.0% were obtained for a 5.9 keV parallel X-ray beam entering the detector through the full size window. The variation of the energy resolution with the X-ray energy is studied and X-ray fluorescence spectra for samples like industrial coal, painted porcelain and car lubrication oil, are presented. (orig.)

  3. KEhD-1 Debye-Sherrar camera with a coordinate proportional counter

    International Nuclear Information System (INIS)

    Ageev, O.I.; Glazova, L.P.; Goganov, D.A.; Rejzis, B.M.; Syrkin, M.G.

    1985-01-01

    An arrangement of the KEhD-1 Debye-Sherrar camera, in which the advantages of a proportional counter are combined with the wide range of simultaneous image recording is described. The camera consists of an X-ray tube unit with the URS-0.1 source, a linear coordinate detector with resistive-capacity coding, a signal transducer and the MK-1 multichannel system for data acquisition and processing based on the ''Uskra-1256'' computer. The counting rate of X-ray pulses is > 5x10 4 s -1 , energy resolution for the CuKsub(α) line constitutes 20%, spatial resolution equals 150 μm, detection efficiency constitutes not less than 64%. The range of the detector displacement varies from -30 deg to +130 deg. The information obtained by means of the camera may be output to a display, a plotter, a numeric printer or a magnetic tape

  4. Recent improvements to RC-line encoded position-sensitive proportional counters

    International Nuclear Information System (INIS)

    Borkowski, C.J.; Kopp, M.K.

    1977-01-01

    Continuing research on the principles of position encoding with RC lines has advanced the design of position-sensitive proportional counters (PSPCs) to meet the requirements for high count rates (>10 5 counts/sec) and good spatial resolution (>10 4 spatial elements) in small-angle scattering experiments with x rays and neutrons. Low-noise preamplifiers were developed with pole-zero cancellation in the feedback circuit and modular linear amplifiers with passive RCL shaping which, compared to previous designs, reduce output saturation at high count rates approx.20 times and shorten the position signal processing time to 2 ) for low-energy ( 800 x 800 mm 2 ) for the measurement of small-angle scattering with neutrons. The method of electronic thickness discrimination was applied to change the effective thickness of an area PSPC from 12 to 2 cm whenever the molybdenum target of an x-ray generator was changed to a copper target. This thickness adjustment increased the signal-to-background ratio by a factor of approx.6 for the 8-keV photons from the copper target, while maintaining a >90% detection efficiency

  5. A suspended boron foil multi-wire proportional counter neutron detector

    Energy Technology Data Exchange (ETDEWEB)

    Nelson, Kyle A.; Edwards, Nathaniel S.; Hinson, Niklas J.; Wayant, Clayton D.; McGregor, Douglas S.

    2014-12-11

    Three natural boron foils, approximately 1.0 cm in diameter and 1.0 µm thick, were obtained from The Lebow Company and suspended in a multi-wire proportional counter. Suspending the B foils allowed the alpha particle and Li ion reaction products to escape simultaneously, one on each side of the foil, and be measured concurrently in the gas volume. The thermal neutron response pulse-height spectrum was obtained and two obvious peaks appear from the 94% and 6% branches of the {sup 10}B(n,α){sup 7}Li neutron reaction. Scanning electron microscope images were collected to obtain the exact B foil thicknesses and MCNP6 simulations were completed for those same B thicknesses. Pulse-height spectra obtained from the simulations were compared to experimental data and matched well. The theoretical intrinsic thermal–neutron detection efficiency for enriched {sup 10}B foils was calculated and is presented. Additionally, the intrinsic thermal neutron detection efficiency of the three natural B foils was calculated to be 3.2±0.2%.

  6. A suspended boron foil multi-wire proportional counter neutron detector

    Science.gov (United States)

    Nelson, Kyle A.; Edwards, Nathaniel S.; Hinson, Niklas J.; Wayant, Clayton D.; McGregor, Douglas S.

    2014-12-01

    Three natural boron foils, approximately 1.0 cm in diameter and 1.0 μm thick, were obtained from The Lebow Company and suspended in a multi-wire proportional counter. Suspending the B foils allowed the alpha particle and Li ion reaction products to escape simultaneously, one on each side of the foil, and be measured concurrently in the gas volume. The thermal neutron response pulse-height spectrum was obtained and two obvious peaks appear from the 94% and 6% branches of the 10B(n,α)7Li neutron reaction. Scanning electron microscope images were collected to obtain the exact B foil thicknesses and MCNP6 simulations were completed for those same B thicknesses. Pulse-height spectra obtained from the simulations were compared to experimental data and matched well. The theoretical intrinsic thermal-neutron detection efficiency for enriched 10B foils was calculated and is presented. Additionally, the intrinsic thermal neutron detection efficiency of the three natural B foils was calculated to be 3.2±0.2%.

  7. Digital signal processing for He3 proportional counter

    International Nuclear Information System (INIS)

    Zeynalov, Sh.S.; Ahmadov, Q.S.

    2010-01-01

    Full text : Data acquisition systems for nuclear spectroscopy have traditionally been based on systems with analog shaping amplifiers followed by analog-to-digital converters. Recently, however, new systems based on digital signal processing make possible to replace the analog shaping and timing circuitry the numerical algorithms to derive properties of the pulse such as its amplitude. DSP is a fully numerical analysis of the detector pulse signals and this technique demonstrates significant advantages over analog systems in some circumstances. From a mathematical point of view, one can consider the signal evolution from the detector to the ADC as a sequence of transformations that can be described by precisely defined mathematical expressions. Digital signal processing with ADCs has the possibility to utilize further information on the signal pulses from radiation detectors. In the experiment each step of the signal generation in the 3He filled proportional counter was described using digital signal processing techniques (DSP). The electronic system has consisted of a detector, a preamplifier and a digital oscilloscope. The pulses from the detector were digitized using a digital storage oscilloscope. This oscilloscope allowed signal digitization with accuracy of 8 bit (256 levels) and with frequency of up to 5 * 10 8 samples/s. As a neutron source was used Cf-252. To obtain detector output current pulse I(t) created by the motions of the ions/electrons pairs was written an algorithm which can easily be programmed using modern computer programming languages.

  8. Alpha–beta monitoring system based on pair of simultaneous Multi-Wire Proportional Counters

    Energy Technology Data Exchange (ETDEWEB)

    Wengrowicz, U.; Amidan, D. [Department of Nuclear Engineering, Ben Gurion University of the Negev, Beer-Sheva 84105 (Israel); NRC-Negev, P.O. Box 9001, Beer-Sheva 84190 (Israel); Orion, I. [Department of Nuclear Engineering, Ben Gurion University of the Negev, Beer-Sheva 84105 (Israel)

    2016-08-11

    A new approach for a simultaneous alpha–beta Multi-wire Proportional Counter (MWPC) is presented. The popular approach for alpha–beta monitoring systems consists of a large area MWPC using noble gas flow such as Argon Methane. This method of measurement is effective but requires large-scale and expensive maintenance due to the needs of gas flow control and periodic replacements. In this work, a pair of simultaneous MWPCs for alpha–beta measuring is presented. The developed detector consists of a sealed gas MWPC sensor for beta particles, behind a free air alpha sensor. This approach allows effective simultaneous detection and discrimination of both alpha and beta radiation without the maintenance cost noble gas flow required for unsealed detectors.

  9. Methods of calculus for neutron spectrometry in proportional counters; Metodos de calculo para espectrometria de neutrones en contadores proporcionales

    Energy Technology Data Exchange (ETDEWEB)

    Butragueno, J L; Blazquez, J B; Barrado, J M

    1976-07-01

    Response functions for cylindrical proportional counters with hydrogenated gases have been determined, taking in account only wall effect, by means of two independent calculus methods. One of them is a Monte Carlo application and the other one analytica at all. Results of both methods have been compared. (Author)

  10. Numerical determination of the amplification of a cylindrical proportional counter operating at low pressure. Application to nano-dosimetry

    International Nuclear Information System (INIS)

    Moutarde, Cyrille

    1994-01-01

    This work is devoted to a study of proportional counters used to measure the energy deposition in micrometer biological sites. Tissue equivalent gas filling improve typical operating mode of those counters. Specially, the extension of the multiplication zone becomes important at low pressures. A Monte Carlo simulation has been used to study the behaviour of an electron swarm in the sensitive volume. The calculations show that electrons are not in equilibrium with the applied electric field in this geometry. The influence of the gradient field and the rotation of the electrons around the anode wire has been studied carefully. The importance of non-equilibrium effects on the theoretical amplification calculated through the ionisation coefficient has been confirmed by experimental investigations. The statistical fluctuations of multiplication process has been calculated by the determination of avalanche spectra at the anode. Resolution of an ultra-miniature counter have been calculated to improve technological limitations of experimental nanodosimetry. (author) [fr

  11. Characteristics of proportional counters used in X-ray radiometric analysis

    International Nuclear Information System (INIS)

    Mamikonyan, S.V.; Martishchenko, L.G.; Mel'ttser, L.V.

    1972-01-01

    Counters with extended (up to 10 cm 2 ) apertres have been described and the results obtained are presented. CPM-15 and CPM-16 counters are intended for sensoring and spectral analysis of X-rays in the range of 2.5 to 23 and 2.5 to 15 keV, respectively. The only difference is in the gas composition. The CPM-15 counter is filled with 90 per cent xenon plus 10 per cent methane used as a quenching dopant. The CPM-16 is filled with 90 per cent argon and 10 per cent methane. The life time is 10 10 pulses at 1800 V for CPM-16 and at 2200 V for CPM-15

  12. Use of tissue equivalent proportional counters to characterize radiation quality on the space shuttle

    International Nuclear Information System (INIS)

    Braby, L.A.; Conroy, T.J.; Elegy, D.C.; Brackenbush, L.W.

    1992-04-01

    Tissue equivalent proportional counters (TEPC) are essentially cavity ionization chambers operating at low pressure and with gas gain. A small, battery powered, TEPC spectrometer, which records lineal energy spectra at one minute intervals, has been used on several space shuttle missions. The data it has collected clearly show the South Atlantic anomaly and indicate a mean quality factor somewhat higher than expected. An improved type of instrument has been developed with sufficient memory to record spectra at 10 second intervals, and with increased resolution for low LET events. This type of instrument will be used on most future space shuttle flights and in some international experiments

  13. Development of multiwire proportional chambers

    CERN Multimedia

    Charpak, G

    1969-01-01

    It has happened quite often in the history of science that theoreticians, confronted with some major difficulty, have successfully gone back thirty years to look at ideas that had then been thrown overboard. But it is rare that experimentalists go back thirty years to look again at equipment which had become out-dated. This is what Charpak and his colleagues did to emerge with the 'multiwire proportional chamber' which has several new features making it a very useful addition to the armoury of particle detectors. In the 1930s, ion-chambers, Geiger- Muller counters and proportional counters, were vital pieces of equipment in nuclear physics research. Other types of detectors have since largely replaced them but now the proportional counter, in new array, is making a comeback.

  14. Digital signal processing for He3 proportional counter

    International Nuclear Information System (INIS)

    Ahmadov, Q.S.; Institute of Radiation Problems, ANAS, Baku

    2011-01-01

    Full text: Data acquisition systems for nuclear spectroscopy have traditionally been based on systems with analog shaping amplifiers followed by analog-to-digital converters. Recently, however, new systems based on digital signal processing allow us to replace the analog shaping and timing circuitry the numerical algorithms to derive properties of the pulse such as its amplitude. DSP is a fully numerical analysis of the detector pulse signals and this technique demonstrates significant advantages over analog systems in some circumstances. From a mathematical point of view, one can consider the signal evolution from the detector to the ADC as a sequence of transformations that can be described by precisely defined mathematical expressions.Digital signal processing with ADCs has the possibility to utilize further information on the signal pulses from radiation detectors [1] [2]. In the experiment each step of the signal generation in the 3He filled proportional counter was described using digital signal processing techniques (DSP). The electronic system has consisted of a detector, a preamplifier and a digital oscilloscope. The pulses from the detector were digitized using a OTSZS-02 (250USB)-4 digital storage oscilloscope from ZAO R UDNEV-SHILYAYEV . This oscilloscope allowed signal digitization with accuracy of 8 bit(256 levels) and with frequency of up to 5.10''8 samples/s. As a neutron source was used Cf-252.To obtain detector output current pulse I(t) created by the motions of the ions/electrons pairs was written an algorithm which can easily be programmed using modern computer programming languages

  15. First results of a simultaneous measurement of tritium and 14C in an ultra-low-background proportional counter for environmental sources of methane

    Energy Technology Data Exchange (ETDEWEB)

    Mace, Emily K.; Aalseth, Craig E.; Day, Anthony R.; Hoppe, Eric W.; Keillor, Martin E.; Moran, James J.; Panisko, Mark E.; Seifert, Allen; Tatishvili, Gocha; Williams, Richard M.

    2016-02-01

    Abstract Simultaneous measurement of tritium and 14C would provide an added tool for tracing organic compounds through environmental systems and is possible via beta energy spectroscopy of sample-derived methane in internal-source gas proportional counters. Since the mid-1960’s atmospheric tritium and 14C have fallen dramatically as the isotopic injections from above-ground nuclear testing have been diluted into the ocean and biosphere. In this work, the feasibility of simultaneous tritium and 14C measurements via proportional counters is revisited in light of significant changes in both the atmospheric and biosphere isotopics and the development of new ultra-low-background gas proportional counting capabilities for small samples (roughly 50 cc methane). A Geant4 Monte Carlo model of a Pacific Northwest National Laboratory (PNNL) proportional counter response to tritium and 14C is used to analyze small samples of two different methane sources to illustrate the range of applicability of contemporary simultaneous measurements and their limitations. Because the two methane sources examined were not sample size limited, we could compare the small-sample measurements performed at PNNL with analysis of larger samples performed at a commercial laboratory. The dual-isotope simultaneous measurement is well matched for methane samples that are atmospheric or have an elevated source of tritium (i.e. landfill gas). For samples with low/modern tritium isotopics (rainwater), commercial separation and counting is a better fit.

  16. Single channel analog pulse processor Asic for gas proportional counters and SI detector

    International Nuclear Information System (INIS)

    Chandratre, V.B.; Sarkar, Soumen; Kataria, S.K.; Viyogi, Y.P.

    2005-01-01

    The paper presents the design and development of a single channel pulse processor in short Singleplex ASIC targeted for gas proportional counters/Si detectors. The design is optimized for the dynamic range of +500 fC to -500 fC with provision for externally adjusted pole-zero cancellation. A dedicated filter based on the de-convolution principle is used for the cancellation of the long hyperbolic signal tail produced by the slow drift of ions, typical in gas proportional with the filter time constants derived from the actual detector input signal shape. The pole-zero adjustment can be done by external dc voltage to achieve perfect base-line recovery to 1% after 5 μs. The simulated 0 pf noise is 500 e - rms for the peaking time of 1.2 μs with noise slope of 7e - -. The gain is 3.4 mv/fC over the entire linear dynamic range with power dissipation of 13 mW. This design is a modified version of Indiplex chip with features dynamic range equal gain on both polarities with nearly same noise and serves as diagnostic chip for Indiplex. The chip can be used for radiation monitoring instruments. (author)

  17. Long life boron-lined proportional counters fitted to the start-up range of the nuclear reactors

    International Nuclear Information System (INIS)

    Dauphin, G.; Duchene, J.

    1983-03-01

    CEA has been engaged in a research and development program in technical cooperation with RTC, to improve the life time of the boron lined proportional counters used for PWR's start up. The present report is a synthesis of these works. The processes by which the discrimination curves show a shift in count rate versus the neutron fluences are described and, the possible ways to get improved performances and the tests performed on the different prototypes are presented. Analysis of the results is given [fr

  18. Radiation protection instruments based on tissue equivalent proportional counters: Part II of an international intercomparison

    International Nuclear Information System (INIS)

    Alberts, W.G.; Dietz, E.; Guldbakke, S.; Kluge, H.; Schumacher, H.

    1988-04-01

    This report describes the irradiation conditions and procedures of Part II of an international intercomparison of tissue-equivalent proportional counters used for radiation protection measurements. The irradiations took place in monoenergetic reference neutron fields produced by the research reactor and accelerator facilities of the PTB Braunschweig in the range from thermal neutrons to 14.8 MeV. In addition measurements were performed in 60 Co and D 2 O-moderated 252 Cf radiation fields. Prototype instruments from 7 European groups were investigated. The results of the measurements are summarized and compared with the reference data of the irradiations. (orig.) [de

  19. Absolute determination of radiation bursts and of proportional counters space charge effect through the influence method

    International Nuclear Information System (INIS)

    Rios, I.J.; Mayer, R.E.

    2016-01-01

    When proportional counters are employed in charge integration mode to determine the magnitude of a radiation pulse, so intense that individual detection events take place in a time too short to produce individual output pulses, mostly in pulsed neutron sources, the strong build-up of positive space charge reduces the electric multiplication factor of the proportional detector. Under such conditions the ensuing measurement underestimates the amount of radiation that interacted with the detector. If the geometric characteristics, the filling gas pressure and the voltage applied to that detector are known, it becomes possible to apply an analytical correction method to the measurement. In this article we present a method that allows to determine the absolute value of the detected radiation burst without the need to know the characteristics of the employed detectors. It is necessary to employ more than one detector, taking advantage of the Influence Method. The “Influence Method” is conceived for the absolute determination of a nuclear particle flux in the absence of known detector efficiency and without the need to register coincidences of any kind. This method exploits the influence of the presence of one detector in the count rate of another detector, when they are placed one behind the other and define statistical estimators for the absolute number of incident particles and for the efficiency (Rios and Mayer, 2015 [1,2]). Its practical implementation in the measurement of a moderated neutron flux arising from an isotopic neutron source was exemplified in (Rios and Mayer, 2016 [3]) and the extension for multiple detectors in (Rios and Mayer 2016 [4]). - Highlights: • Absolute determination of radiation burst. • Proportional counters space charge effect. • Radiation measurements on pulsed devices.

  20. A powerful, low-cost histogramming memory for digital radiography with multi-wire proportional counters

    International Nuclear Information System (INIS)

    Bateman, J.E.; Locke, C.E.R.; Ferrari, C.A.

    1986-01-01

    A powerful, low-cost histogramming memory for digital radiograph with multi-wire proportional counter is described. The memory is based on a commercial video display device coupled to an Apple II microcomputer which, at a total cost of around 2500 pounds gives a system with 512 x 512 pixel resolution and a counting range of 4095 counts per pixel. The system can take data at rates of up to 5000 Hz while providing a live-time display. No hardware modifications are necessary, the comprehensive storage and display facilities being implemented in a combined package of BASIC and ASSEMBLER software. An ACCELERATOR coprocessor card is used to enhance the performance of the system. (author)

  1. Dual-chamber/dual-anode proportional counter incorporating an intervening thin-foil solid neutron converter

    International Nuclear Information System (INIS)

    Boatner, Lynn A.; Neal, John S.; Blackston, Matthew A.; Kolopus, James A.; Ramey, Joanne O.

    2012-01-01

    A dual-chamber/dual-anode gas proportional counter utilizing thin solid 6 LiF or 10 B neutron converters coated on a 2-micon-thick Mylar film that is positioned between the two counter chambers and anodes has been designed, fabricated, and tested using a variety of fill gases—including naturally abundant helium. In this device, neutron conversion products emitted from both sides of the coated converter foil are detected—rather than having half of the products absorbed in the wall of a conventional tube-type counter where the solid neutron converter is deposited on the tube wall. Geant4-based radiation transport calculations were used to determine the optimum neutron converter coating thickness for both isotopes. Solution methods for applying these optimized-thickness coatings on a Mylar film were developed that were carried out at room temperature without any specialized equipment and that can be adapted to standard coating methods such as silk screen or ink jet printing. The performance characteristics of the dual-chamber/dual-anode neutron detector were determined for both types of isotopically enriched converters. The experimental performance of the 6 LiF-converter-based detector was described well by modeling results from Geant4. Additional modeling studies of multiple-foil/multiple-chamber/anode configurations addressed the basic issue of the relatively longer absorption range of neutrons versus the shorter range of the conversion products for 6 LiF and 10 B. Combined with the experimental results, these simulations indicate that a high-performance neutron detector can be realized in a single device through the application of these multiple-foil/solid converter, multiple-chamber detector concepts.

  2. Helium-filled proportional counter and its operation mechanism at low temperatures

    CERN Document Server

    Isozumi, Y; Kishimoto, S

    2002-01-01

    The operation mechanism of helium-filled proportional counter (HFPC) at about 4.2 K is explained. Unstable behavior of HFPC is caused by releasing secondary-electron from the cathode by four kinds of active particles such as He sub n sup + , non-resonance photon from excited helium atom, non-resonance photon from He sub 2 sup * (A sup 1 Su sup +) and He sub 2 sup m (a sup 3 Su sup +). On experiments of HFPC behavior at low temperature, the following facts were observed; 1) main charge formation process in the electron avalanche is direct ionization by electron without Hornbeck-Molnar process. Accordingly, the gas amplification factor becomes small at low temperature. 2) Stable helium cation is He sub 2 sup + at room temperature, but cluster at low temperature. Large after-pulse is observed in output signal depends on cluster ion. The probability of secondary-electron emission decreased. The gas gain increased with increasing anode voltage. 3) By decreasing reaction rate of atom and molecule collision at low t...

  3. MCNP modelling of the wall effects observed in tissue-equivalent proportional counters.

    Science.gov (United States)

    Hoff, J L; Townsend, L W

    2002-01-01

    Tissue-equivalent proportional counters (TEPCs) utilise tissue-equivalent materials to depict homogeneous microscopic volumes of human tissue. Although both the walls and gas simulate the same medium, they respond to radiation differently. Density differences between the two materials cause distortions, or wall effects, in measurements, with the most dominant effect caused by delta rays. This study uses a Monte Carlo transport code, MCNP, to simulate the transport of secondary electrons within a TEPC. The Rudd model, a singly differential cross section with no dependence on electron direction, is used to describe the energy spectrum obtained by the impact of two iron beams on water. Based on the models used in this study, a wall-less TEPC had a higher lineal energy (keV.micron-1) as a function of impact parameter than a solid-wall TEPC for the iron beams under consideration. An important conclusion of this study is that MCNP has the ability to model the wall effects observed in TEPCs.

  4. Development of a parallel plate proportional counter TRD with suppressed sensitivity to ionization

    International Nuclear Information System (INIS)

    Solomey, N.; Krolak, P.; Graham, G.

    1995-01-01

    The development of a Parallel Plate Proportional Counter which has a highly suppressed sensitivity to ionization but retains a good X-ray signal to noise ratio is presented. Details of the laboratory development and actual beam tests showing the e/π rejection are described. Because of its insensitivity to ionization this type of detector can be useful in an environment where the number of minimum ionizing particles are high, but uninteresting; however, the detector is very sensitive to the highly localized electron cloud from converted X-rays making it ideal as a transition radiation X-ray detector. Thus, this detector only gives a signal for charged particles above TR threshold; all other particles below this threshold produce no TR X-rays giving only a pedestal-like signal. The system's potential performance for π/p separation in the intended neutral Hyperon experiment is evaluated

  5. Qualitative and quantative analysis of some physical processes encountered in measurements of low level radon activity by means of proportional counter

    International Nuclear Information System (INIS)

    Bluszcz, A.; Moscicki, W.

    1980-01-01

    Physical model for absorption of radon and its decay products on the electrodes of the proportional counter filled with Rn-CO 2 mixture is presented. The results of calculations based on developed model are compared with observed changes of counting rate of radon and its decay products. (author)

  6. Search of 2K(2ν) capture in 78 Kr and 124 Xe by means of wall-less proportional counters

    International Nuclear Information System (INIS)

    Volchenko, G.V.; Gavrilyuk, Yu.M.; Kuz'minov, V.V.; Osetrova, N.Ya.; Ratkevich, S.S.

    1998-01-01

    The technique of the experiment on the double two-neutrino K-capture search in isotopes of rare gases 78 Kr and 124 Xe is described. Multiwire wall-less proportional counters of a large volume are used in this experiment. Methods of decreasing the counter background noise in the energy range 10-100 keV are considered. These methods are based on the discrimination of events on the coordinate along the anode filament and the pulse rise time. The sensitivity of the experimental installation is estimated according to the half-life 78 Kr (1.2 x 10 21 years) and 124 Xe (2.6 x 10 20 years) with respect to the 2K(2ν) capture (68% certain level)

  7. Errors in estimating neutron quality factor using lineal energy distributions measured in tissue-equivalent proportional counters

    International Nuclear Information System (INIS)

    Borak, T.B.; Stinchcomb, T.G.

    1982-01-01

    Neutron dose equivalent is obtained from quality factors which are defined in terms of LET. It is possible to estimate the dose averaged quality factor, antiQ, directly from distributions in lineal energy, y, that are measured in tissue-equivalent proportional counters. This eliminates a mathematical transformation of the absorbed dose from D(y) to D(L). We evaluate the inherent error in computing Q from D(y) rather than D(L) for neutron spectra below 4 MeV. The effects of neutron energy and simulated tissue diameters within a gas cavity are examined in detail. (author)

  8. The Rutherford Appleton Laboratory's Mark I multiwire proportional counter positron camera

    International Nuclear Information System (INIS)

    Bateman, J.E.; Connolly, J.F.; Stephenson, R.; Tappern, G.J.; Flesher, A.C.

    1984-01-01

    A small (30 cmx30 cm) model of a proposed large aperture positron camera has been developed at Rutherford Appleton Laboratory. Based on multiwire proportional counter technology, it uses lead foil cathodes which function simultaneously as converters for the 511 keV gamma rays and readout electrodes for a delay line readout system. The detectors have been built up into a portable imaging system complete with a dedicated computer for data taking, processing and display. This has permitted evaluation of this type of positron imaging system in the clinical environment using both cyclotron generated isotopes ( 15 O, 11 C, 18 F, 124 I) and available isotopic generator systems ( 82 Rb, 68 Ga). AT RAL we provided a complete hardware system and sufficient software to permit our hospital based colleagues to generate useful images with the minimum of effort. A complete description of the system is given with performance figures and some of the images obtained in three hospital visits are presented. Some detailed studies of the imaging performance of the positron camera are reported which have bearing on the design of future, improved systems. (orig.)

  9. Development and Characterization of Tissue Equivalent Proportional Counter for Radiation Monitoring in International Space Station

    Directory of Open Access Journals (Sweden)

    Uk-Won Nam

    2013-06-01

    Full Text Available Tissue equivalent proportional counter (TEPC can measure the Linear Energy Transfer (LET spectrum and calculate the equivalent dose for the complicated radiation field in space. In this paper, we developed and characterized a TEPC for radiation monitoring in International Space Station (ISS. The prototype TEPC which can simulate a 2 μm of the site diameter for micro-dosimetry has been tested with a standard alpha source (241Am, 5.5 MeV. Also, the calibration of the TEPC was performed by the 252Cf neutron standard source in Korea Research Institute of Standards and Science (KRISS. The determined calibration factor was kf = 3.59×10-7 mSv/R.

  10. A model for the operation of helium-filled proportional counter at low temperatures near 4.2 K

    International Nuclear Information System (INIS)

    Masaoka, Sei; Katano, Rintaro; Kishimoto, Shunji; Isozumi, Yasuhito

    2000-01-01

    In order to understand the operation of helium-filled proportional counter (HFPC) from the standpoint of fundamental atomic and molecular processes, we have surveyed previous works on collision processes in discharged helium gas. By analyzing gas gain curve, after-pulses and discharge current experimentally observed at 4.2 K, the electron avalanche and the secondary electron emission from cathode have been related to the collision processes in helium. A simplified model for the HFPC operation at low temperatures near 4.2 K has been constructed with the related processes

  11. Needle counter

    International Nuclear Information System (INIS)

    Fujita, Yuzo

    1977-01-01

    Needle counter had been devised by Geiger about 60 years ago before the present GM counter appeared. It is suitable for the detection of weak radiation because it is limited in effective volume, if the background due to mainly cosmic ray is proportional to the effective volume of the counter. Recently the very low β detector having a needle counter as the main detector has been developed. It showed highly excellent performance in the measurements of small area samples, about ten times sensitive as compared with other detectors. The counter is installed in the very low radiation measuring well at Nokogiriyama, Chiba Prefecture, using a NaI scintillator as its guard counter. D. H. Wilkinson first treated a gas amplification counter theoretically and quantitatively. The authors have obtained good results in the comparison with the experiments of the counter using a generalized form of Wilkinson theory. The findings obtained through this study seem to be applicable to the electrode arrangement which is important for the counter design. It was found that the excellent rise time of induced pulses in a gas amplification counter was achieved in larger amplification factor and smaller convolution effect. In the detection of charged particles with small obstructing capability such as γ ray, faster rise time and higher pulses can be obtained with needle counters than wire counters. (Wakatsuki, Y.)

  12. Preliminary results from a high-pressure imaging spectroscopic proportional counter

    International Nuclear Information System (INIS)

    Hall, C.J.; Bazzano, A.; Lewis, R.A.; Parker, B.; Ubertini, P.; Worgan, J.S.

    1992-01-01

    A new type of high-pressure proportional counter, with both spatial resolution and spectroscopic capabilities is being jointly developed by the Istituto di Astrofisica Spaziale (CNR), Frascati, Italy and the SERC Daresbury Laboratory, Warrington, UK. The characteristics of the detector can be optimized for the particular requirement of the experiment, either for x-ray astronomy observations from space, or for the high count rate applications associated with a synchrotron light source. In its baseline configuration, the detector is filled to 5 bar with a xenon/quench gas mixture and will be sensitive over the energy range 5 keV to 150 keV (2.5 to 0.08 A). The positional resolution will range from 500 μm at the lower energies to around 1 mm at the higher end of the energy range. The current prototype has a sensitive area of 200x200 mm. The final version is hoped to have an area closer to 425x425 mm. The very small photon absorption length in the higher pressure gas allows the parallax effect, a feature of 1 atmosphere detectors, to be greatly reduced. The timing resolution (150 ns) of the detector enables both a high-rate capability and the possibility of the escape gate technique to achieve higher spectral resolution at energies > the Xe K edge. Preliminary results are presented showing the spectral and positional resolution for the prototype detector

  13. Light yield as a function of gas pressure and electric field in gas scintillation proportional counters

    International Nuclear Information System (INIS)

    Favata, F.; Smith, A.; Bavdaz, M.; Kowalski, T.Z.

    1990-01-01

    We have investigated the dependence of the scintillation light output for Xe on gas pressure in the range 0.14-1.4 bar, using a gas scintillation proportional counter, in different experimental configurations. We have compared our work with that of previous workers, and have shown that both our results and the results of previous authors are compatible with the intrinsic light output being independent of gas pressure, with any observed dependence being a pure experimental effect due to the spectral response of the various UV detectors used. We also use our experimental data for determining the ratio between the cross section of the Xe 2 ** +Xe→Xe 2 * +Xe reaction and the rate of the Xe 2 ** →2Xe+γ UV reaction. (orig.)

  14. Radiation effects on the proportional counter X-ray detectors on board the NEAR spacecraft

    International Nuclear Information System (INIS)

    Floyd, S.R.; Trombka, J.I.; Leidecker, H.W.; Clark, P.E.; Starr, R.; Goldsten, J.O.; Roth, D.R.

    1999-01-01

    The X-ray proportional counters on board the Near Earth Asteroid Rendezvous (NEAR) spacecraft have exhibited a resolution degradation and recovery phenomenon several times during the long cruise phase of the mission. The resolution is checked periodically by commanding an 55 Fe source into the window area. The degradation is seen as a low energy tailing of the 5.9 keV photopeak. Two events have occurred which provided good spectral data for better understanding the degradation phenomenon. In November 1997 a large solar particle event occurred that degraded the resolution and excited copper in the collimator. Eventually the detectors returned to normal. In January 1998 the spacecraft performed an Earth swingby gravity assist maneuver. The near Earth environment excited the magnesium and aluminum in the filter elements. The copper line was also produced. The NEAR spacecraft was launched in February 1996 and will rendezvous and orbit the asteroid 433 Eros in early 1999

  15. Development of extruded resistive plastic tubes for proportional chamber cathodes

    International Nuclear Information System (INIS)

    Kondo, K.

    1982-01-01

    Carbon mixed plastic tubes with resistivity of 10 3 approx. 10 4 Ωcm have been molded with an extrusion method and used for the d.c. cathode of a proportional counter and a multi-wire proportional chamber. The signal by gas multiplication was picked up from a strip r.f. cathode set outside the tube. The characteristics of the counter in the proportional and limited streamer modes have been studied

  16. A primary scintillation gated high pressure position sensitive gas scintillation proportional counter (HPGSPC) for applications to x-ray astronomy

    International Nuclear Information System (INIS)

    Giarrusso, S.; Manzo, G.; Re, S.

    1985-01-01

    The authors describe a new instrument for x-ray astronomy. The instrument, based on a high pressure (5 atm.), xenon filled, position sensitive Gas Scintillation Proportional counter (HPGSPC) is expected to feature an energy resolution better than 4% at 60 keV, an angular resolution of approximately 20 arc-minutes over the full energy range (4 to 100 keV) and a field of view (FOV) of up to 30x30 degrees. A prototype flight unit of the gas cell on which the instrument is based is presently under technological development in the framework of the SAX project

  17. Photon and neutron dose discrimination using low pressure proportional counters with graphite and A150 walls

    International Nuclear Information System (INIS)

    Kylloenen, J.; Lindborg, L.

    2005-01-01

    Full text: The determination of both the low- and high-LET components of ambient dose equivalent in mixed fields is possible with microdosimetric methods. With the multiple-event microdosimetric variance covariance method the sum of those components are directly obtained also in pulsed beams. However, if the value of each dose component is needed a more extended analysis is required. The use of a graphite walled proportional detector in combination with a tissue-equivalent proportional counter in combination with the variance covariance method was here investigated. MCNP simulations were carried out for relevant energies to investigate the photon and neutron responses of the two detectors. The combined graphite and TEPC system, the Sievert instrument, was used for measurements at IRSN, Cadarache, in the workplace calibration fields of CANEL+, SIGMA, a Cf-252 and a moderated Cf(D 2 O,Cd) radiation field. The response of the instrument in various monoenergetic neutron fields is also known from measurements at PTB. The instrument took part in the measurement campaigns in workplace fields in the nuclear industry organized within the EVIDOS contract. The results are analyzed and the method of using a graphite detector compared with alternative methods of analysis is discussed. (author)

  18. Detection of pulsed fast neutrons by a proportional counter boron-convered and enveloped in paraffin moderators

    International Nuclear Information System (INIS)

    Goncalez, O.L.; Yanagihara, L.S.; Veissid, V.L.C.P.; Herdade, S.B.

    1983-01-01

    The response to pulsed fast neutrons by a parafin moderated boron-lined proportional counter is investigated theoretically and experimentally. The neutrons pulses are generated by 60 MeV electrons from a linear accelerator. The calculation of the counting loss based on the detector dead time and on the exponential decresse of the thermal neutron population in the moderator is presented in detail. An analytical relation between the true counting rate and the reduced one, indicated by the detector, is found. In this formula three parameters appear: the decay constant of the thermal neutron population, the detector dead time and the pulse frequency of the neutron source. The decay constant is calculated by diffusion theory. The experimental results for six values of moderator thickness (between 2.5 to 12.5 cm) agree with our theoretical calculation within 20 per cent. (Author) [pt

  19. Background simulation for the Spherical Proportional Counter and its use for the detection of optical photons

    International Nuclear Information System (INIS)

    Bougamont, E; Colas, P; Dastgheibi-Fard, A; Derre, J; Giomataris, I; Gerbier, G; Gros, M; Magnier, P; Navick, X F; Tsiledakis, G; Salin, P; Savvidis, I; Vergados, J D

    2013-01-01

    The recently developed Spherical Proportional Counter [1] allows to instrument large target masses with good energy resolution and sub-keV energy threshold. The moderate cost of this detector, its simplicity and robustness, makes this technology a promising approach for many domains of physics and applications, like dark matter detection and low energy neutrino searches. Detailed Monte Carlo simulations are essential to evaluate the background level expected at the sub-keV energy regime. The simulated background here, it refers to the contribution of the construction material of the detector and the effect of the environmental gamma radiation. This detector due to its spherical shape could be also served as an optical photon detector provided it is equipped with PMTs, for Double Beta decay and Dark Matter searches. All calculations shown here are obtained using the FLUKA Monte Carlo code

  20. Calibration of the Large Area X-Ray Proportional Counter (LAXPC) Instrument on board AstroSat

    Energy Technology Data Exchange (ETDEWEB)

    Antia, H. M.; Yadav, J. S.; Chauhan, Jai Verdhan; Chitnis, Varsha; Dedhia, Dhiraj; Shah, Parag; Gujar, V. M.; Katoch, Tilak; Kurhade, V. N.; Madhwani, Pankaj; Manojkumar, T. K.; Nikam, V. A.; Pandya, A. S.; Parmar, J. V.; Pawar, D. M. [Tata Institute of Fundamental Research, Homi Bhabha Road, Mumbai 400005 (India); Agrawal, P. C. [UM-DAE Centre of Excellence for Basic Sciences, University of Mumbai, Kalina, Mumbai 400098 (India); Manchanda, R. K. [University of Mumbai, Kalina, Mumbai 400098 (India); Paul, Biswajit [Department of Astronomy and Astrophysics, Raman Research Institute, Bengaluru 560080 (India); Pahari, Mayukh; Misra, Ranjeev [Inter-University Centre for Astronomy and Astrophysics, Pune 411007 (India); and others

    2017-07-01

    We present the calibration and background model for the Large Area X-ray Proportional Counter (LAXPC) detectors on board AstroSat . The LAXPC instrument has three nominally identical detectors to achieve a large collecting area. These detectors are independent of each other, and in the event analysis mode they record the arrival time and energy of each photon that is detected. The detectors have a time resolution of 10 μ s and a dead-time of about 42 μ s. This makes LAXPC ideal for timing studies. The energy resolution and peak channel-to-energy mapping were obtained from calibration on the ground using radioactive sources coupled with GEANT4 simulations of the detectors. The response matrix was further refined from observations of the Crab after launch. At around 20 keV the energy resolution of the detectors is 10%–15%, while the combined effective area of the three detectors is about 6000 cm{sup 2}.

  1. PEP quark search proportional chambers

    Energy Technology Data Exchange (ETDEWEB)

    Parker, S I; Harris, F; Karliner, I; Yount, D [Hawaii Univ., Honolulu (USA); Ely, R; Hamilton, R; Pun, T [California Univ., Berkeley (USA). Lawrence Berkeley Lab.; Guryn, W; Miller, D; Fries, R [Northwestern Univ., Evanston, IL (USA)

    1981-04-01

    Proportional chambers are used in the PEP Free Quark Search to identify and remove possible background sources such as particles traversing the edges of counters, to permit geometric corrections to the dE/dx and TOF information from the scintillator and Cerenkov counters, and to look for possible high cross section quarks. The present beam pipe has a thickness of 0.007 interaction lengths (lambdasub(i)) and is followed in both arms each with 45/sup 0/ <= theta <= 135/sup 0/, ..delta..phi=90/sup 0/ by 5 proportional chambers, each 0.0008 lambdasub(i) thick with 32 channels of pulse height readout, and by 3 thin scintillator planes, each 0.003 lambdasub(i) thick. Following this thin front end, each arm of the detector has 8 layers of scintillator (one with scintillating light pipes) interspersed with 4 proportional chambers and a layer of lucite Cerenkov counters. Both the calculated ion statistics and measurements using He-CH/sub 4/ gas in a test chamber indicate that the chamber efficiencies should be >98% for q=1/3. The Landau spread measured in the test was equal to that observed for normal q=1 traversals. One scintillator plane and thin chamber in each arm will have an extra set of ADC's with a wide gate bracketing the normal one so timing errors and tails of earlier pulses should not produce fake quarks.

  2. 90Sr- 90Y and 89Sr beta radioactivity measurement in milk samples using a proportional counter

    International Nuclear Information System (INIS)

    Mananes, A.; Perez Santos, C.; Martinez Churiaque, F.

    1987-01-01

    A thin window glas flow proportional counter is used to measure the 90 Sr- 90 Y and 89 Sr beta radioactivity in milk samples. A chemical procedure is used to separate strontium-yttrium from the other radionuclides present in milk. A calculation of the total efficiency of the system is performed which includes an empirical estimation of the backscattering factor. The calibration of the whole process allows the determination of the 90 Sr activity within 10% relative error in spite of uncertainties in the recovery yields of strontium and yttrium. No 89 Sr activity has been detected, and the mean value obtained for the 90 Sr activity in nine milk samples of Cantabria is 0.115 Bq/1 with a minimum detectable activity of 0.0105 Bq. (author) 18 refs

  3. Development of NRESP98 Monte Carlo codes for the calculation of neutron response functions of neutron detectors. Calculation of the response function of spherical BF{sub 3} proportional counter

    Energy Technology Data Exchange (ETDEWEB)

    Hashimoto, M.; Saito, K.; Ando, H. [Power Reactor and Nuclear Fuel Development Corp., Oarai, Ibaraki (Japan). Oarai Engineering Center

    1998-05-01

    The method to calculate the response function of spherical BF{sub 3} proportional counter, which is commonly used as neutron dose rate meter and neutron spectrometer with multi moderator system, is developed. As the calculation code for evaluating the response function, the existing code series NRESP, the Monte Carlo code for the calculation of response function of neutron detectors, is selected. However, the application scope of the existing NRESP is restricted, the NRESP98 is tuned as generally applicable code, with expansion of the geometrical condition, the applicable element, etc. The NRESP98 is tested with the response function of the spherical BF{sub 3} proportional counter. Including the effect of the distribution of amplification factor, the detailed evaluation of the charged particle transportation and the effect of the statistical distribution, the result of NRESP98 calculation fit the experience within {+-}10%. (author)

  4. Evaluation of B10Plus+* proportional detectors for neutron coincidence counting

    Energy Technology Data Exchange (ETDEWEB)

    Beddingfield, David H.; Yoon, Seokryung [International Atomic Energy Agency, Vienna International Centre, PO Box 100, 1400 Vienna, (Austria)

    2015-07-01

    GE-Reuter-Stokes (GERS) has developed a new line of neutron proportional counters, the B10Plus+* proportional counter. The detector design is intended to serve as a cost-effective alternative to traditional {sup 3}He proportional counters in a variety of applications. The detector is a hybrid design 10B-lined tube optimized with the addition of a small quantity of 3He gas to improve the detector performance and efficiency. As a demonstration of the B10Plus+* detector, GERS has constructed a Uranium Neutron Collar (UNCL) system consisting of B-10Plus+* proportional counters. GERS has designed and built a demonstration UNCL system intended to match the performance of a Type-I UNCL design in Pressurized Water Reactor (PWR) geometry operating in thermal mode. GERS offered their system on loan to the International Atomic Energy Agency (IAEA) Safeguards Division of Technical and Scientific Services for an assessment of the detector technology and the demonstration system. We have characterized the demonstration UNCL system and compared its performance with a traditional Type-I UNCL design in regular use by the IAEA. This paper summarizes our findings and observations during the characterization and testing activity. (authors)

  5. An investigation of the effect of some gaseous admixtures on the ionization currents in the air in the discharge chambers of the proportional counter type

    International Nuclear Information System (INIS)

    Berdowska, E.; Zastawny, A.

    1981-01-01

    Voltage-current characteristics of the ionization discharge in chambers of the proportional counter filled with air with admixtures of CO, CO 2 , CH 4 and H 2 O have been investigated. It was found that in the transition region between dependent and self-maintained discharge the characteristics change sufficiently for detection of the presence of those admixtures in the air. (author)

  6. Calibration of a low background gas-flow proportional counter to estimate "2"3"4Th activity in coastal waters

    International Nuclear Information System (INIS)

    Cuesta, E.; Lozano, R.L.; Miguel, E.G. San; Casas-Ruiz, M.; Bolívar, J.P.

    2016-01-01

    This paper relates the calibration of a low background gas-flow proportional counter. This calibration has been used to determine low activity of "2"3"4Th in coastal water samples. Two methods were used to prepare calibration samples: Evaporation and Electrodeposition. First method was rejected due to the lack of reproducibility because the different geometry adopted by the drops of tracer once dried on the disk. On the contrary, through the second method, similar efficiencies were obtained in all detectors with an average of 0.401±0.004. In this paper, the whole procedure to obtain "2"3"4Th activity in dissolution as well as in particulate matter has been detailed, and all the algorithms needed to calculate activities and efficiencies are shown. Finally, two experiments have been designed in order to validate the calibration of the beta counter and the method to determine "2"3"4Th in coastal waters with high concentration of particulate matter. - Highlights: • This paper shows a Home-made calibration using two methods to prepare calibration samples. • The algorithms needed to obtain Th-234 activity concentrations are described in full detail. • This is the first time Th-234 has been determined in water samples from Huelva Estuary.

  7. The study of the influence of helium on the counter's measurement properties

    International Nuclear Information System (INIS)

    Guan Rui; Weng Kuiping; Ren Xingbi

    2009-04-01

    In measurement of tritium by the proportional counter, methane is usually used as counter gas. Gas samples have been made with helium and methane in the proportion of concentration and measured to study the influence of helium on the counter's measurement properties. Then gas sample with tritium and helium has been measured, and the result is according with anticipation. The experiment has showed that the plateau curve of counter could be changed by helium, but the influence could be ignored when helium concentration less 10%. (authors)

  8. Response of a carbon-walled proportional counter to 14 MeV neutrons

    International Nuclear Information System (INIS)

    Lewis, K.D.

    1982-01-01

    The response of a carbon-walled spherical proportional counter filled with a methane-based tissue-equivalent gas mixture at low pressure and irradiated with 14 MeV neutrons is first measured experimentally and is then calculated theoretically by using an analytical model. The model, called the CISS model, is derived from a consideration of four basic modes of interaction of charged particles generated in neutron-nucleus reactions with the spherical cavity of the detector. Since several quantities which have application in neutron dosimetry, radiation protection, and radiation biology make direct use of such spectra, it is desirable to have the ability to theoretically predict what is expected experimentally. Thus, a comparison between the two response curves is made. The discrepancy between them is investigated by considering several physical phenomena occurring within the detector wall which tend to distort the experimental response curve. In particular, the C(n,n',3α) reaction occurring in the detector wall gives rise to multiple events, originating from a single neutron interaction in the wall simultaneously strike the detector cavity, and are recorded as a single larger event in an experimental spectra. In the analytic model, the simultaneous entry of two charged particles into the cavity is scored as two separate smaller events, uncorrelated in their production. In this work, an effort is made to modify the analytic model prediction of the response curve by correcting for the multiple events which occur. Finally, the CISS model is used to compute mass stopping power corrections for this inhomogeneous detector

  9. Nuclear accident dosimetry: the calibration of Geiger-Mueller and 2π proportional counters for sulphur and gold

    International Nuclear Information System (INIS)

    Delafield, H.J.; Reading, A.H.

    1981-10-01

    A reference, 2π precision counter was set up at Harwell and absolutely calibrated for the measurement of sulphur discs ( 32 P) and gold foils ( 198 Au) used in the UK personnel criticality dosimeter. Sample sulphur discs and gold foils were irradiated in the GLEEP reactor at Harwell, counted in the 2π counter, and their activities absolutely assayed by the National Physical Laboratory. The 2π counter was then used to intercalibrate the GM counters used routinely for the assessment of the criticality dosimeter. The mean measured efficiencies of the GM counters were found to be for 32 P in sulphur discs within +- 4%, and for gold ( 198 Au) within +- 6% of the values given by previous calibrations. (author)

  10. From the High Energy Physics Laboratory to the hospital -some experiences of the application of MWPC [multiwire proportional counter] technology to medicine

    International Nuclear Information System (INIS)

    Bateman, J.E.

    1989-01-01

    In this talk I wish to briefly review the experience we have obtained at the Rutherford Appleton Laboratory over the past decade in the adaptation of MWPC (multiwire proportional counter) technology to diagnostic imaging applications in medicine. A cursory glance at the history of science and technology quickly shows the often intimate and mutually beneficial relationship between ''pure'' science (and scientists) and practical applications. The following talk traces some of the principal features of the situation which have been brought to my attention in the course of the last decade. (author)

  11. A Neutron Rem Counter

    Energy Technology Data Exchange (ETDEWEB)

    Andersson, I Oe; Braun, J

    1964-01-15

    A neutron detector is described which measures the neutron dose rate in rem/h independently of the energy of the neutrons from thermal to 15 MeV. The detector consists of a BF{sub 3} proportional counter surrounded by a shield made of polyethylene and boron plastic that gives the appropriate amount of moderation and absorption to the impinging neutrons to obtain rem response. Two different versions have been developed. One model can utilize standard BF{sub 3} counters and is suitable for use in installed monitors around reactors and accelerators and the other model is specially designed for use in a portable survey instrument. The neutron rem counter for portable instruments has a sensitivity of 2.4 cps/mrem/h and is essentially nondirectional in response. With correct bias setting the counter is insensitive to gamma exposure up to 200 r/h from Co-60.

  12. Simulated Response of a Tissue-equivalent Proportional Counter on the Surface of Mars.

    Science.gov (United States)

    Northum, Jeremy D; Guetersloh, Stephen B; Braby, Leslie A; Ford, John R

    2015-10-01

    Uncertainties persist regarding the assessment of the carcinogenic risk associated with galactic cosmic ray (GCR) exposure during a mission to Mars. The GCR spectrum peaks in the range of 300(-1) MeV n to 700 MeV n(-1) and is comprised of elemental ions from H to Ni. While Fe ions represent only 0.03% of the GCR spectrum in terms of particle abundance, they are responsible for nearly 30% of the dose equivalent in free space. Because of this, radiation biology studies focusing on understanding the biological effects of GCR exposure generally use Fe ions. Acting as a thin shield, the Martian atmosphere alters the GCR spectrum in a manner that significantly reduces the importance of Fe ions. Additionally, albedo particles emanating from the regolith complicate the radiation environment. The present study uses the Monte Carlo code FLUKA to simulate the response of a tissue-equivalent proportional counter on the surface of Mars to produce dosimetry quantities and microdosimetry distributions. The dose equivalent rate on the surface of Mars was found to be 0.18 Sv y(-1) with an average quality factor of 2.9 and a dose mean lineal energy of 18.4 keV μm(-1). Additionally, albedo neutrons were found to account for 25% of the dose equivalent. It is anticipated that these data will provide relevant starting points for use in future risk assessment and mission planning studies.

  13. Controlling low-rate signal path microdischarge for an ultra-low-background proportional counter

    International Nuclear Information System (INIS)

    Mace, E.K.; Aalseth, C.E.; Bonicalzi, R.M.; Day, A.R.; Hoppe, E.W.; Keillor, M.E.; Myers, A.W.; Overman, C.T.; Seifert, A.

    2013-01-01

    Pacific Northwest National Laboratory (PNNL) has developed an ultra-low-background proportional counter (ULBPC) made of high purity copper. These detectors are part of an ultra-low-background counting system (ULBCS) in the newly constructed shallow underground laboratory at PNNL (at a depth of ∼30 m water-equivalent). To control backgrounds, the current preamplifier electronics are located outside the ULBCS shielding. Thus the signal from the detector travels through ∼1 m of cable and is potentially susceptible to high voltage microdischarge and other sources of electronic noise. Based on initial successful tests, commercial cables and connectors were used for this critical signal path. Subsequent testing across different batches of commercial cables and connectors, however, showed unwanted (but still low) rates of microdischarge noise. To control this noise source, two approaches were pursued: first, to carefully validate cables, connectors, and other commercial components in this critical signal path, making modifications where necessary; second, to develop a custom low-noise, low-background preamplifier that can be integrated with the ULBPC and thus remove most commercial components from the critical signal path. This integrated preamplifier approach is based on the Amptek A250 low-noise charge-integrating preamplifier module. The initial microdischarge signals observed are presented and characterized according to the suspected source. Each of the approaches for mitigation is described, and the results from both are compared with each other and with the original performance seen with commercial cables and connectors. (author)

  14. Pulse formation of gas-filled counter

    International Nuclear Information System (INIS)

    Iwatani, Kazuo; Teshima, Kazunori; Shizuma, Kiyoshi; Hasai, Hiromi

    1991-01-01

    The pulse formation of gas-filled counter has been calculated by simple models for the proportional and self-quenching streamer (SQS) modes. Calculated pulse shapes of counter output have accurately reproduced the observed ones for both modes. As a result, it is shown that the special density distribution of ion pairs in a streamer can be estimated with the rising part of observed pulse shape, using the model. (author)

  15. New proportional counter for in vivo detection of traces of plutonium in the lungs; Nouveau compteur proportionnel destine a la detection in vivo de traces de plutonium dans les poumons

    Energy Technology Data Exchange (ETDEWEB)

    Morucci, J [Commissariat a l' Energie Atomique, Centre d' Etudes Nucleaires de Saclay, 91 - Gif-sur-Yvette (France)

    1966-07-01

    Development of a multi-wire proportional counter having a uniform response over 250 cm{sup 2} thanks to corrections made for boundary effects, and having a low background per sq. cm. due to the use of two identical counters set in anti-coincidence in the same enclosure is described. (author) [French] Etude et mise au point d'un compteur proportionnel multifils de reponse utile homogene sur une surface de 250 cm{sup 2} grace a la correction des effets de bords et de faible mouvement propre par cm{sup 2} grace a deux compteurs identiques montes en anticoincidence dans la meme enceinte. (auteur)

  16. Azimuthal spread of the avalanche in proportional chambers

    International Nuclear Information System (INIS)

    Okuno, H.; Fischer, J.; Radeka, V.; Walenta, A.H.

    1978-10-01

    The angular distribution of the avalanche around the anode wire in the gas proportional counter is determined by measuring the distribution of positive ions arriving on cathode strips surrounding the anode wire for each single event. The shape and width of the distribution depend on such factors as the gas gain, the anode diameter, the counting gas and the primary ionization density. Effects of these factors are studied systematically, and their importance for practical counter applications is discussed

  17. Measurement and analysis of neutron flux distribution of STACY heterogeneous core by position sensitive proportional counter. Contract research

    CERN Document Server

    Murazaki, M; Uno, Y

    2003-01-01

    We have measured neutron flux distribution around the core tank of STACY heterogeneous core by position sensitive proportional counter (PSPC) to develop the method to measure reactivity for subcritical systems. The neutron flux distribution data in the position accuracy of +-13 mm have been obtained in the range of uranium concentration of 50g/L to 210g/L both in critical and in subcritical state. The prompt neutron decay constant, alpha, was evaluated from the measurement data of pulsed neutron source experiments. We also calculated distribution of neutron flux and sup 3 He reaction rates at the location of PSPC by using continuous energy Monte Carlo code MCNP. The measurement data was compared with the calculation results. As results of comparison, calculated values agreed generally with measurement data of PSPC with Cd cover in the region above half of solution height, but the difference between calculated value and measurement data was large in the region below half of solution height. On the other hand, ...

  18. The x-ray spectrum of the Cygnus Loop measured with Gas Scintillation Proportional Counters

    International Nuclear Information System (INIS)

    Tsunemi, Hiroshi; Manabe, Makoto; Yamashita, Koujun; Koyama, Katsuji.

    1988-01-01

    We report the results of an observation of the whole Cygnus Loop performed with the Gas Scintillation Proportional Counters (GSPC) on board the Tenma satellite. Line emissions around 1.9 keV and 2.5 keV, probably originating from silicon and sulfur Kα line blends, were detected. The continuum spectrum in the energy range 1-3 keV can be represented by a thermal bremsstrahlung spectrum with a temperature of 7 x 10 6 K. This is the highest value for the Cygnus Loop reported so far. The Tenma data were also combined with those from a sounding rocket flight performed previously, in which a similar detector system was employed. Thus, we obtain a wide-band X-ray spectrum for the whole Cygnus Loop with the best energy resolution reported so far. The combined data could not be fitted by a single temperature component in the thermal collisional ionization equilibrium (CIE) model or a single-temperature nonequilibrium ionization (NEI) model. A good fit is obtained if at least two temperature components are included in both the CIE and NEI models. However, only the NEI model allows a self consistent interpretation. Taking into account the emission measures for both components, we can conclude that the low-temperature, high-density component arises mainly from the shell region and that the high-temperature, low-density component arises from the interior of the shell. (author)

  19. Einstein Observatory SSS and MPC observations of the complex X-ray spectra of Seyfert galaxies. [Solid State Spectrometer and Monitor Proportional Counter

    Science.gov (United States)

    Turner, T. J.; Weaver, K. A.; Mushotzky, R. F.; Holt, S. S.; Madejski, G. M.

    1991-01-01

    The X-ray spectra of 25 Seyfert galaxies measured with the Solid State Spectrometer on the Einstein Observatory have been investigated. This new investigation utilizes simultaneous data from the Monitor Proportional Counter, and automatic correction for systematic effects in the Solid State Spectrometer which were previously handled subjectively. It is found that the best-fit single-power-law indices generally agree with those previously reported, but that soft excesses of some form are inferred for about 48 percent of the sources. One possible explanation of the soft excess emission is a blend of soft X-ray lines, centered around 0.8 keV. The implications of these results for accretion disk models are discussed.

  20. Simultaneous measurement of tritium and radiocarbon by ultra-low-background proportional counting.

    Science.gov (United States)

    Mace, Emily; Aalseth, Craig; Alexander, Tom; Back, Henning; Day, Anthony; Hoppe, Eric; Keillor, Martin; Moran, Jim; Overman, Cory; Panisko, Mark; Seifert, Allen

    2017-08-01

    Use of ultra-low-background capabilities at Pacific Northwest National Laboratory provide enhanced sensitivity for measurement of low-activity sources of tritium and radiocarbon using proportional counters. Tritium levels are nearly back to pre-nuclear test backgrounds (~2-8 TU in rainwater), which can complicate their dual measurement with radiocarbon due to overlap in the beta decay spectra. We present results of single-isotope proportional counter measurements used to analyze a dual-isotope methane sample synthesized from ~120mg of H 2 O and present sensitivity results. Copyright © 2017 Elsevier Ltd. All rights reserved.

  1. Contributions to the methodology of multiwire proportional chambers

    International Nuclear Information System (INIS)

    Petrascu, H.

    1993-01-01

    The Ph.D. thesis presents first the realization, testing, optimization, and use of detection equipment based on position sensitive multiwire proportional chambers (MWPC), high resolution proportional counters, and of ΔE,E ionization chambers. In the second chapter it is presented the realization MWPC, in which the coordinate information is obtained by means of LC-delay lines, containing many original constructive elements. By using a system of three MWPC in coincidence, an experimental testing of the theoretically predicted pion generation in the 235 U fission process, was performed. An upper limit of 10 -11 for this process was found. In the 3-rd chapter there are presented the developments of high resolution proportional counters for X-ray spectrometry. Various penning mixtures of high purity gases were studied. The purity of gases was assured by a technology described in a Romanian patents. These counters are currently use in various applications as a rapid analysis of steel marks and in the mining industry. the 4-th chapter is dedicated to the construction and using of ΔE,E closed, high resolution ionization chambers. With these chambers the multinucleon transfer in the 27 Al( 14 M, X) reaction at 116 MeV bombarding energy was investigated. Also this type of chambers was used for the elaboration of an absolute method for analysis and profiling of impurities in silicon wafers. This method is described in the last part of the chapter. (Author) 117 Figs., 8 Tabs., 55 Refs

  2. Measurement and analysis of neutron flux distribution of STACY heterogeneous core by position sensitive proportional counter. Contract research

    Energy Technology Data Exchange (ETDEWEB)

    Murazaki, Minoru; Uno, Yuichi; Miyoshi, Yoshinori [Japan Atomic Energy Research Inst., Tokai, Ibaraki (Japan). Tokai Research Establishment

    2003-03-01

    We have measured neutron flux distribution around the core tank of STACY heterogeneous core by position sensitive proportional counter (PSPC) to develop the method to measure reactivity for subcritical systems. The neutron flux distribution data in the position accuracy of {+-}13 mm have been obtained in the range of uranium concentration of 50g/L to 210g/L both in critical and in subcritical state. The prompt neutron decay constant, {alpha}, was evaluated from the measurement data of pulsed neutron source experiments. We also calculated distribution of neutron flux and {sup 3}He reaction rates at the location of PSPC by using continuous energy Monte Carlo code MCNP. The measurement data was compared with the calculation results. As results of comparison, calculated values agreed generally with measurement data of PSPC with Cd cover in the region above half of solution height, but the difference between calculated value and measurement data was large in the region below half of solution height. On the other hand, calculated value agreed well with measurement data of PSPC without Cd cover. (author)

  3. Las comparaciones interpersonales y la evaluación de estados sociales alternativos

    Directory of Open Access Journals (Sweden)

    Casas , Andrés Fernando

    2003-06-01

    Full Text Available Este ensayo revisa diferentes aproximaciones de la teoría económica para evaluar estados sociales alternativos, a partir de la formulación de una función de bienestar social que admita o niegue comparaciones interpersonales de utilidad. Analiza en especial los puntos de vista de la vieja y la nueva economía del bienestar. Y concluye que con los aportes de Amartya Sen al concepto de bienestar como funcionamiento y al de justicia como capacidad de elegir entre diversos funcionamientos, es posible considerar de manera distinta a los agentes y evaluar opciones alternativas de condiciones de vida.

  4. Realisation and qualification of a tissue equivalent proportional counter with a multi-cellular geometry for the individual neutron dosimetry

    International Nuclear Information System (INIS)

    Hoflack, Ch.

    1999-01-01

    The present day dosimetry means for radiations with a strong ionization density cannot fulfill the future radioprotection regulations which will require an individual dosimetry with active dosemeters. The aim of this work is the study and development of an individual dosemeter based on a tissue equivalent proportional counter and with a multi-cellular geometry allowing to reach a sensibility equivalent to environmental dosemeters. A pressure regulation bench has been added to the detector in order to reduce the degassing of the detector parts and to reach a sufficient service life for the implementation of the characterization tests. The hole counter system has been adopted for the first prototypes in order to reduce the sensibility of the wires multiplication system with respect to mechanical vibrations. Tests performed with an internal alpha source have shown that a better electrical efficiency can be reached when more severe mechanical limits are adopted during the construction. The dose equivalent response of the prototype for mono-energy neutrons of 144 keV to 2.5 MeV is analyzed experimentally and by simulation. During experiments with normal incidence neutrons, the prototype fulfills the requirements of the CEI N O 1323 standard for energies comprised between 400 keV and 2.5 MeV, while the simulation indicates a satisfactory response up to 200 keV. A preliminary study of the behaviour of the detector with respect to the neutrons incidence indicates that the multi-cellular geometry is efficient for large angles (the sensibility of the prototype is increased by a factor 3). Finally, simulation studies have to be made to optimize the electrical operation and the geometry of the next prototype. (J.S.)

  5. Discrimination capability of avalanche counters detecting different ionizing particles

    International Nuclear Information System (INIS)

    Prete, G.; Viesti, G.; Padua Univ.

    1985-01-01

    The discrimination capability of avalanche counters to detect different ionizing particles has been studied using a 252 Cf source. Pulse height, pulse-height resolution and timing properties have been measured as a function of the reduced applied voltage for parallel-plate and parallel-grid avalanche counters. At the highest applied voltages, space charge effects shift the pulse-height signal of the avalanche counter away from being linearly proportional to the stopping power of the detected particles and cause the pulse-height resolution to deteriorate. To optimize the avalanche counter capability, without loss of time resolution, it appears better to operate the detector at voltages well below the breakdown threshold. Measurements with 32 S ions are also reported. (orig.)

  6. Simultaneous measurement of tritium and radiocarbon by ultra-low-background proportional counting

    Energy Technology Data Exchange (ETDEWEB)

    Mace, Emily; Aalseth, Craig; Alexander, Tom; Back, Henning; Day, Anthony; Hoppe, Eric; Keillor, Martin; Moran, Jim; Overman, Cory; Panisko, Mark; Seifert, Allen

    2017-08-01

    Use of ultra-low-background capabilities at Pacific Northwest National Laboratory provide enhanced sensitivity for measurement of low-activity sources of tritium and radiocarbon using proportional counters. Tritium levels are nearly back to pre-nuclear test backgrounds (~2-8 TU in rainwater), which can complicate their dual measurement with radiocarbon due to overlap in the isotope’s respective energy spectra. This activity makes direct dual-isotope measurements challenging without additional chemistry to concentrate the tritium in a sample. We present results of single-isotope proportional counter measurements used to analyze a dual-isotope methane sample synthesized from ~120 mg of H2O and present sensitivity results.

  7. Proportional gas scintillation detectors and their applications

    International Nuclear Information System (INIS)

    Petr, I.

    1978-01-01

    The principle is described of a gas proportional scintillation detector and its function. Dependence of Si(Li) and xenon proportional detectors energy resolution on the input window size is given. A typical design is shown of a xenon detector used for X-ray spetrometry at an energy of 277 eV to 5.898 keV and at a gas pressure of 98 to 270 kPa. Gas proportional scintillation detectors show considerable better energy resolution than common proportional counters and even better resolution than semiconductor Si(Li) detectors for low X radiation energies. For detection areas smaller than 25 mm 2 Si(Li) detectors show better resolution, especially for higher X radiation energies. For window areas 25 to 190 mm 2 both types of detectors are equal, for a window area exceeding 190 mm 2 the proportional scintillation detector has higher energy resolution. (B.S.)

  8. Multiwire proportional chamber for Moessbauer spectroscopy: development and results

    International Nuclear Information System (INIS)

    Costa, M.S. da.

    1985-12-01

    A new Multiwere proportional Chamber designed for Moessbauer Spectroscopy is presented. This detector allows transmission backscattering experiments using either photons or electrons. The Moessbauer data acquisition system, partially developed for this work is described. A simple method for determining the frontier between true proportional and semi-proportional regions of operation in gaseous detectors is proposed. The study of the tertiary gas mixture He-Ar-CH 4 leads to a straight forward way of energy calibration of the electron spectra. Moessbauer spectra using Fe-57 source are presented. In particular those obtained with backsattered electrons show the feasibility of depth selective analysis with gaseous proportional counters. (author) [pt

  9. The response of a spherical tissue-equivalent proportional counter to 56-Fe particles from 200-1000 MeV/nucleon

    Energy Technology Data Exchange (ETDEWEB)

    Gersey, Bradford B.; Borak, Thomas B.; Guetersloh, Stephen B.; Zeitlin, Cary J.; Miller, J.; Heilbronn, L.; Murakami, T.; Iwata, Y.

    2001-09-04

    The radiation environment aboard the space shuttle and the International Space Station includes high-Z and high-energy (HZE) particles that are part of the galactic cosmic radiation (GCR) spectrum. Iron-56 is considered to be one of the most biologically important parts of the GCR spectrum. Tissue-equivalent proportional counters (TEPC) are used as active dosimeters on manned space flights. These TEPC's are further used to determine average quality factor for each space mission. A TEPC simulating a 1 micron diameter sphere of tissue was exposed as part of a particle spectrometer to iron-56 at energies from 200-1000 MeV/nucleon. The response of TEPC in terms of frequency-averaged lineal energy, dose-averaged lineal energy, as well as energy deposited at different impact parameters through detector was determined for six different incident energies of iron-56 in this energy range. Calculations determined that charged particle equilibrium was achieved for each of the six experiments. Energy depositions at different impact parameters were calculated using a radial dose distribution model and the results compared to experimental data.

  10. Multiwire proportional counter (lecture by an electromagnetic delay line)

    International Nuclear Information System (INIS)

    Bruere-Dawson, R.

    1989-01-01

    For track localisation of ionizing particles with multiwire proportional chamber, an electronic chain including amplifying, shaping and memorizing circuits is required for each wire. In order to lower the cost of this type of detector, an electromagnetic delay line is proposed among various possibilities. In this paper, different coupling modes between chamber and delay line are studied with their respective advantages. The realization of one meter long delay line with a unit delay time of 15 ns per cm is also presented [fr

  11. Optimization of Counting Times, Figure of Merit and Mass Thickness for Low-background Alpha/beta Proportional Counter in Sea Water

    International Nuclear Information System (INIS)

    Pakkong, Pannee; Wongsanit, Sarinya; Tumnoi, Yutthana; Udomsomporn, Suchin

    2011-06-01

    Full text: The determination of gross alpha and beta activity in environmental aqueous samples can be done by using a low-background alpha/beta proportional counter with multiple detector type (Bert hold LB770). The co precipitate sea water samples were considered for optimal regime of counting time, the minimum detectable activity (MDA), mass thickness of samples (mg/cm-2) and figure of merit (FOM). The result showed that the MDA of the measurements were estimated to be 0.07 Bq/l for gross alpha and 0.05 Bq/l for gross beta at counting time of 100 and 200 minute, respectively. The thickness of samples prepared by coprecipitation technique indicated more parochial range when compared to evaporation to dryness method. In addition, the samples were in the suitable range that can be corrected by the previous self-absorption correction factor (F a ) as 0.0003w 2 -0.0414 w+1.692; where F a is the self-absorption correction factor and w is the weight of the final precipitate in milligrams

  12. Calculations of the response functions of Bonner spheres with a spherical 3He proportional counter using a realistic detector model

    International Nuclear Information System (INIS)

    Wiegel, B.; Alevra, A.V.; Siebert, B.R.L.

    1994-11-01

    A realistic geometry model of a Bonner sphere system with a spherical 3 He-filled proportional counter and 12 polyethylene moderating spheres with diameters ranging from 7,62 cm (3'') to 45,72 cm (18'') is introduced. The MCNP Monte Carlo computer code is used to calculate the responses of this Bonner sphere system to monoenergetic neutrons in the energy range between 1 meV to 20 MeV. The relative uncertainties of the responses due to the Monte Carlo calculations are less than 1% for spheres up to 30,48 cm (12'') in diameter and less than 2% for the 15'' and 18'' spheres. Resonances in the carbon cross section are seen as significant structures in the response functions. Additional calculations were made to study the influence of the 3 He number density and the polyethylene mass density on the response as well as the angular dependence of the Bonner sphere system. The calculated responses can be adjusted to a large set of calibration measurements with only a single fit factor common to all sphere diameters and energies. (orig.) [de

  13. Quality control of total alpha and beta activity analysis in water using the Proportional Counter of Gaseous Flux technique; Controle de qualidade das análises de atividades alfa e beta total em água pela técnica do Contador Proporcional de Fluxo Gasoso

    Energy Technology Data Exchange (ETDEWEB)

    Neto, Alberto P.; Bastos, Thiago M.R.; Santos, Thiago O.; Filho, Crescêncio A.S.; França, Elvis J. de, E-mail: albertopereiran@gmail.com, E-mail: thiagomrbastos@gmail.com, E-mail: thiago_cbufpe@yahoo.com.br, E-mail: candrade@cnen.gov.br, E-mail: ejfranca@cnen.gov.br [Centro Regional de Ciências Nucleares do Nordeste (CRCN-NE/CNEN-PE), Recife, PE (Brazil)

    2017-07-01

    The analytical capacity of the CRCN (Centro Regional de Ciências Nucleares do Nordeste) for quantification of total alpha and beta concentrations in water samples using the Proportional Counter of Gaseous Flux is presented. To demonstrate the traceability of the results, the National Intercomparison Program (PNI) samples were used, promoted by the Institute of Radioprotection and Dosimetry (IRD) from which the Regional Nuclear Science Center of the Northeast (CRCN-NE) participates since 2011. The results reported to the PNI demonstrate the analytical capacity of the CRCN to detect the emission of alpha and beta radioactivities in water within the potability standards in analytical detection of quantification in radioactivity by the technique of the Proportional Flow Counter.

  14. A gas proportional scintillation counter for use in large area detector systems without photomultipliers

    International Nuclear Information System (INIS)

    Baruch, J.E.F.; Brooke, G.; Kellermann, E.W.; Bateman, J.E.; Connolly, J.F.

    1978-03-01

    The properties of a prototype gas proportional scintillation detector, for use in large numbers, are examined. The detector is designed to focus a light signal, which is proportional to ionisation loss, into a fibre optic lightguide. It is shown that a single charged particle traversing the detector produces enough light out of the lightguide to be seen by a TV camera. Problems of lifetime and large scale detector production are discussed. Properties of saturation, linearity, position sensitivity, and operating limits are examined. It is shown that an array of gas proportional scintillation detectors when used with fibre optic lightguides and TV camera readout could offer significant improvements in cost per area and reliability over a scintillator plus photomultiplier or a wire proportional chamber array. (author)

  15. Introduction to Neutron Coincidence Counter Design Based on Boron-10

    Energy Technology Data Exchange (ETDEWEB)

    Kouzes, Richard T.; Ely, James H.; Lintereur, Azaree T.; Siciliano, Edward R.

    2012-01-22

    The Department of Energy Office of Nonproliferation Policy (NA-241) is supporting the project 'Coincidence Counting With Boron-Based Alternative Neutron Detection Technology' at Pacific Northwest National Laboratory (PNNL) for development of an alternative neutron coincidence counter. The goal of this project is ultimately to design, build and demonstrate a boron-lined proportional tube based alternative system in the configuration of a coincidence counter. This report, providing background information for this project, is the deliverable under Task 1 of the project.

  16. Dead zone characteristics of a gas counter

    International Nuclear Information System (INIS)

    Nohtomi, Akihiro; Sakae, Takeji; Matoba, Masaru; Koori, Norihiko.

    1990-01-01

    The dead zone was recently defined as the product of dead length and dead time in order to describe the characteristics of the self-quenching streamer (SQS) mode of a gas counter. Investigation of the dead zone characteristics has been extended for the proportional and GM modes, and the measured dead zone has been compared with that of the SQS mode. Accurate values for the dead zone could be determined by means of a newly developed method with a pulse interval time to amplitude converter. Each operation mode indicates distinct dead zone characteristics. Properties of gas counters for high counting rates may be improved on the basis of measurements of the dead zone. (author)

  17. Counter-diffusion and -permeation of deuterium and hydrogen through metals

    Energy Technology Data Exchange (ETDEWEB)

    Kizu, Kaname; Tanabe,; Tetsuo, [Nagoya Univ. (Japan)

    1998-03-01

    The first experiments for counter-diffusion and -permeation of deuterium and hydrogen through palladium were performed. Deuterium permeation rates against D{sub 2} pressure were measured under the condition where hydrogen permeated to opposite direction by supplying H{sub 2} gas at the permeated side of D{sub 2}. It was found that not a small amount of deuterium was clearly permeated even if the deuterium pressure was much smaller than the hydrogen pressure. Deuterium permeation rate was gradually reduced by increasing the counter H permeation. The deuterium permeation rate under the counter H permeation is well represented by a simple model in which the ratio of the deuterium permeation rates with and without the counter H permeation was proportional to the fractional concentration of deuterium in the bulk. As increasing the hydrogen counter flow, however, the deuterium permeation rate deviates from the model. This means that adsorption (absorption) of D{sub 2} from gas phase is inhibited and surface recombination of deuterium is blocked by hydrogen. (author)

  18. A new neutron counter for fission research

    Energy Technology Data Exchange (ETDEWEB)

    Laurent, B., E-mail: benoit.laurent@cea.fr [CEA, DAM, DIF, F-91297 Arpajon (France); Granier, T.; Bélier, G.; Chatillon, A.; Martin, J.-F.; Taieb, J. [CEA, DAM, DIF, F-91297 Arpajon (France); Hambsch, F.-J. [EC-JRC Institute for Reference Materials and Measurements (IRMM), Retieseweg, 2440 Geel (Belgium); Tovesson, F.; Laptev, A.B.; Haight, R.C.; Nelson, R.O.; O' Donnell, J.M. [Los Alamos Neutron Science Center, Los Alamos National Laboratory, Los Alamos, NM 87545 (United States)

    2014-05-01

    A new neutron counter for research experiments on nuclear fission has been developed. This instrument is designed for the detection of prompt fission neutrons within relatively high levels of gamma and neutron background. It is composed of a set of {sup 3}He proportional counters arranged within a block of polyethylene which serves as moderator. The detection properties have been studied by means of Monte Carlo simulations and experiments with radioactive sources. These properties are confirmed by an experiment on neutron-induced fission of {sup 238}U at the WNR facility of the Los Alamos Neutron Science Center during which the mean prompt fission neutron multiplicity, or ν{sup ¯} has been measured from 1 to 20 MeV of incident neutron energy.

  19. Design of nuclear pulse shaped circuit based on proportional counter

    International Nuclear Information System (INIS)

    Song Qianqian; Cheng Yi; Tuo Xianguo

    2011-01-01

    Use the self-developed proportional to sample gas tritium in environment and make the measurement. For this detector, a kind of pulse shape circuit based on second order active low pass filtering circuit realized filtering and shaping nuclear pulse by high-speed operational amplifier, with less stages that has been approved for filter Gaussian wave. Use Multisim 10.0 to simulate the different parameters of the filter circuit. The simulation result was consistent with the theoretical results. The experiments proved the feasibility of this circuit, and at the same time provided a convenient and reliable method for analysis and optimization of the nuclear pulse waveform in order for discriminating by MCA. (authors)

  20. The Proportional Counter. Some Aspects of Operation; Le compteur proportionnel. Ses caracteristiques de fonctionnement; Proportsional'nyj schetchik. Nekotorye aspekty raboty; El contador proportional. Sus caracteristicas de funcionamiento

    Energy Technology Data Exchange (ETDEWEB)

    Curran, S C [Awre, Aldermaston (United Kingdom)

    1960-06-15

    1. Work on a counter system designed for electron capture studies has shown that the diameter of the anode wire in a high-pressure proportional counter can have an important influence on the energy resolution obtained in measurements of low-energy radiations. In a counter working at a pressure of 12 atmospheres the width of the pulse distribution due to 13.5 keV K-capture radiations could be changed from 65% to 17% by changing the wire diameter from 0.0076 mm to 0.0025 mm. This phenomenon is interpreted as an effect of positive ion space charge in the avalanche. For a given gas gain and primary radiation the density of positive ions in the avalanche increases rapidly with pressure of the filling gas, and when the accompanying electric fields are large enough to affect the last stages of the multiplication process the energy resolution of the counter deteriorates. Decrease in diameter of the anode wire increases the externally applied field in the region where multiplication takes place, thus tending to counteract the effect of space charge. Use of 0.0025 mm anode wires has proved satisfactory in new measurements of L/K capture ratios made with a multiwire counter system working at pressures up to 12 atmospheres. The results obtained for L/K capture ratios of Ge{sup 71} and Kr{sup 79} are 0.115 and 0.112 respectively. The same counting system has also been used in a search for M capture in these two isotopes. The low energy of the M capture radiation, 180 eV in Ge{sup 71} and 260 eV in Kr{sup 79}, and its low intensity relative to that of K capture, makes accurate measurement difficult; but peaks attributable to M capture were observed in pulse spectra of both sources. 2. Low-Background Counting - Recent observations made on a combination of proportional counter and scintillation counters (operating as shields) show that there are some real difficulties in devising a relatively simple system of this kind. The performance is inherently very satisfactory but practical

  1. Tritium assay in hydrogen gas by proportional counter with magnetic tape recording

    International Nuclear Information System (INIS)

    Grabczak, J.

    1982-03-01

    Analytical procedure is discussed concerning routine tritium activity determination in water samples based on hydrogen production from the water sample and radioactivity measurement by gas proportional counting. The method was found to be fully comparable to the widely adopted technique of liquid scintillation counting with electrolytic enrichment

  2. Numerical modeling of working of a multicellular proportional counter aimed to individual dosimetry of neutrons

    International Nuclear Information System (INIS)

    Bordy, J.M.; Barthe, J.; Boutruche, B.

    1993-01-01

    The use of a personal dosimeter imposes severe constraints, particularly for tension of polarization and tolerable dimensions. That why a numerical modeling of this detector working is an appreciable help for conception. It allows to determine quickly the influence of modification of different parameters (nature and pressure of gas, dimension of electrodes, dimension of channels, tension of polarization,...) without having to make new prototypes. The aim of this report is to give some numerical results got with a multicellular counter with a cylindrical geometry. 6 figs

  3. Distributed performance counters

    Science.gov (United States)

    Davis, Kristan D; Evans, Kahn C; Gara, Alan; Satterfield, David L

    2013-11-26

    A plurality of first performance counter modules is coupled to a plurality of processing cores. The plurality of first performance counter modules is operable to collect performance data associated with the plurality of processing cores respectively. A plurality of second performance counter modules are coupled to a plurality of L2 cache units, and the plurality of second performance counter modules are operable to collect performance data associated with the plurality of L2 cache units respectively. A central performance counter module may be operable to coordinate counter data from the plurality of first performance counter modules and the plurality of second performance modules, the a central performance counter module, the plurality of first performance counter modules, and the plurality of second performance counter modules connected by a daisy chain connection.

  4. proportional counting chamber for large-area-coated β sources

    Indian Academy of Sciences (India)

    The system consists of a multiwire-based proportional counter with gas ... volume of the detector to avoid any loss of detection efficiency due to absorption in the entrance ... Figure 1. (a) Energy levels of 90Sr decay scheme and (b) energy distribution of β- ... High voltage is applied to the anode grid and high electric field is.

  5. Study and full simulation of ten different gases on sealed Multi-Wire Proportional Counter (MWPC) by using Garfield and Maxwell codes

    International Nuclear Information System (INIS)

    Shohani, M. Ebrahimi; Golgoun, S.M.; Aminipour, M.; Shabani, A.; Mazoochi, A.R.; Akbari, R. Maghsoudi; Mohammadzadeh, M.; Davarpanah, M.R.; Sardari, D.; Sadeghi, M.; Mofrad, F. Babapour; Jafari, A.

    2016-01-01

    In this research gas sealed Multi-Wire Proportional Counter (MWPC) including blades between anode wires and beta particles of "9"0Sr with 196 keV mean energy were considered. Ten different gases such as Noble gases mixtures with methane and several other pure gases were studied. In this type of detector, by using Garfield and Maxwell codes and for each of the gases, variation of different parameters such as first Townsend, electron attachment coefficients with variable electric field and their effects on pulse height or collected charge and in turn on Signal to Noise Ratio (SNR) were studied. Also the effect of anode voltage and its diameter and the pressure of gas on the pulse height were studied. Results show that Garfield and Maxwell codes can be used to study and improve the design of other gaseous detectors. - Highlights: • Simulation of different gases that is applicable for various gas detectors. • Two simulation codes were used and analyzed their results for beta particle. • Different detector parameters were studied (SNR, first Townsend, electron attachment coefficients, anode voltage and etc.). • The effect of blade in the detector were assessed. • The codes are useful for design and improvement of detector.

  6. Coincidence measurements with the use of detectors measuring the energy of the radiances (proportional meters and scintillation counter); Mesures de coincidences avec utilisation de detecteurs mesurant l'energie des rayonnements (compteurs proportionnels et compteur a scintillations)

    Energy Technology Data Exchange (ETDEWEB)

    Sartory, M [Commissariat a l' Energie Atomique, Saclay(France). Centre d' Etudes Nucleaires

    1953-07-01

    In the setting of the realization of a set of installations permitting of the measures of coincidences between sorted radiances according to their energies, an installation understanding a proportional counter and a scintillation counter has been constructed and optimized. It has been used to do some measures of coincidences between X{sub K} photons and photons {gamma} issued at the time of the radioactive transformation of the selenium 75 (electronic capture). The efficiency of the proportional meter has been determined roughly. Besides, a proportional counter of solid angle neighboring of 4{pi} was able to achieve measures of coincidences while only doing one selection of amplitudes: indeed, the simultaneity of the detection of two radiances appear by an impulse whose amplitude is the sum of the amplitudes of the impulses resulting from each of the studied radiations. This method, applied to the coincidences between X-rays, permitted to bring the information on the diagram of decay of the arsenic 73. Besides, the coefficient of internal conversion of a consecutive transition to this decay has been valued. (author) [French] Dans le cadre de la realisation d'une serie de montages permettant des mesures de coincidences entre rayonnements tries d'apres leurs energies, un montage comprenant un compteur proportionnel et un compteur a scintillations a ete construit et mis au point. Il a ete utilise pour effectuer quelques mesures de coincidences entre photons X{sub K} et photons {gamma} emis lors de la transformation radioactive du selenium 75 (capture electronique). L'efficacite du compteur proportionnel a ete approximativement determinee. De plus, un compteur proportionnel d'angle solide voisin de 4{pi} a pu etre utilise pour realiser des mesures de coincidences en n'effectuant qu'une selection d'amplitudes: en effet, la simultaneite de la detection de deux rayonnements se manifeste par une impulsion dont l'amplitude est la somme des amplitudes des impulsions

  7. The Energy Variation of the Sensitivity of a Polyethylene Moderated BF{sub 3} Proportional Counter

    Energy Technology Data Exchange (ETDEWEB)

    Fraeki, R; Leimdoerfer, M; Malmskog, S

    1962-11-15

    The variation with neutron energy of the sensitivity of a polyethylene moderated boron counter has been investigated experimentally at 2.3 MeV, 550 keV, 210 keV, 110 keV, 340 eV and 5 eV, and theoretically by the multigroup diffusion method in the same range. Different moderator thicknesses up to 10 cm were considered Results show good agreement between experimental and theoretical sensitivities for the keV and MeV energies, while a discrepancy of the order of a factor 2 at the most is obtained in the eV region.

  8. Over-the-counter medications containing diphenhydramine and doxylamine used by older adults to improve sleep.

    Science.gov (United States)

    Abraham, Olufunmilola; Schleiden, Loren; Albert, Steven M

    2017-08-01

    Background The unintentional misuse of over-the-counter sleep aids among older adults is an important public health problem and a focus of Healthy People 2020. Accordingly, the 2015 Beers Criteria for Potentially Inappropriate Medication Use in Older Adults recommends that individuals 65 years or older avoid use of diphenhydramine and doxylamine; however, many over-the-counter sleep products contain these active ingredients. Objective To identify the proportion of older adults using an over-the-counter medication containing diphenhydramine or doxylamine, and compare their characteristics with older adults using an over-the-counter medication that does not contain these ingredients. Setting Study participants were recruited from the Community Registry of the Pittsburgh Claude D. Pepper Older Americans Independence Center. Method The study sample was taken from a larger survey of 1025 participants on sleep health and over-the-counter sleep medication use conducted from February to April 2015. A subset of 169 participants aged 65 and older reporting taking at least one over-the-counter product to improve sleep within the past 30 days (16.5%) were selected for our analysis on associations between participant characteristics and potentially inappropriate use of over-the-counter sleep medications. Main outcome measure The proportion and characteristics of older adults taking at least one over-the-counter medication containing diphenhydramine or doxylamine. Results Of the 223 over-the-counter sleep medications listed by participants, 115 (52%) contained diphenhydramine or doxylamine. Using the Beers Criteria, we found that more than half of participants (59%) had used a potentially inappropriate over-the-counter medication containing diphenhydramine or doxylamine to improve sleep within the past 30 days. Participants taking at least one diphenhydramine or doxylamine containing medication were less likely to be aware of any safety risks in taking over-the-counter sleep

  9. Absolute measurements with a 4 {pi}-counter

    Energy Technology Data Exchange (ETDEWEB)

    Martinsson, Kerstin

    1959-06-15

    Measurements on standardized p-emitters have been made in a 4 it proportional flow-counter. The counter efficiency is found to be near 100 %. Absorption curves have been determined with plastic foils and aluminium. A comparison is made between the self-absorption arising in different methods of source preparation which include precipitates and the use of wetting agents The most reliable results have been obtained with sources on aluminium foils, where the foil absorption is calculated from the absorption curves and the self-absorption is supposed to be negligible for isotopes with end point energy above 0.5 MeV. The {beta}-emitters studied have energies ranging from 1.71 MeV ({sup 32}P) to 0.167 MeV ({sup 35}S). Most of them have been obtained from National Physical Laboratory and Atomic Energy Research Establishment, Harwell, England. The agreement between their calibration and our measurements is very good except in the case of Co 60.

  10. Absolute measurements with a 4 π-counter

    International Nuclear Information System (INIS)

    Martinsson, Kerstin

    1959-06-01

    Measurements on standardized p-emitters have been made in a 4 it proportional flow-counter. The counter efficiency is found to be near 100 %. Absorption curves have been determined with plastic foils and aluminium. A comparison is made between the self-absorption arising in different methods of source preparation which include precipitates and the use of wetting agents The most reliable results have been obtained with sources on aluminium foils, where the foil absorption is calculated from the absorption curves and the self-absorption is supposed to be negligible for isotopes with end point energy above 0.5 MeV. The β-emitters studied have energies ranging from 1.71 MeV ( 32 P) to 0.167 MeV ( 35 S). Most of them have been obtained from National Physical Laboratory and Atomic Energy Research Establishment, Harwell, England. The agreement between their calibration and our measurements is very good except in the case of Co 60

  11. Cerenkov counters at ISABELLE

    International Nuclear Information System (INIS)

    Etkin, A.; Kostoulas, I.; Leith, D.W.G.S.; Thun, R.

    1977-01-01

    The Cherenkov counter described for use at Isabelle is a threshold counter in which light is focussed on phototubes. The counter is applicable in large-angle, small-aperture magnetic spectrometers for measurement of particle yields at large p/sub T/. Three of these counters will provide complete π-K-p separation in the range of 7-20 GeV/c. Other Cherenkov counters are discussed and a bibliography of relevant literature on the counters utilizing photoionization is included

  12. The acetone bandpass detector for inverse photoemission: operation in proportional and Geiger–Müller modes

    Science.gov (United States)

    Thiede, Christian; Niehues, Iris; Schmidt, Anke B.; Donath, Markus

    2018-06-01

    Inverse photoemission is the most versatile experimental tool to study the unoccupied electronic structure at surfaces of solids. Typically, the experiments are performed in the isochromat mode with bandpass photon detectors. For gas-filled counters, the bandpass behavior is realized by the combination of the photoionization threshold of the counting gas as the high-pass filter and the ultraviolet transmission cutoff of an alkaline earth fluoride entrance window as the low-pass filter. The transmission characteristics of the entrance window determine the optical bandpass. The performance of the counter depends on the composition of the detection gas and the fill-gas pressure, the readout electronics and the counter geometry. For the well-known combination of acetone and CaF2, the detector can be operated in proportional and Geiger–Müller modes. In this work, we review aspects concerning the working principles, the counter construction and the read-out electronics. We identify optimum working parameters and provide a step-by-step recipe how to build, install and operate the device.

  13. Multimode pulse counter

    International Nuclear Information System (INIS)

    Natanzon, D.D.

    1982-01-01

    A pulse counter with code conversion is described. The counter is based on the integrated circuits of direct-counting devices of medium integration. The counter ensures various modes of pulse counting depending on the logical control signals: reversible, two-channel summing, one-channel summing binary, summing with ''storage'' signal code fixation without interrupting pulse counting. Arrangement of the suggested structure as a microcircuit of medium integration might contribute to reduction in the counter type nomenclature in digital families of widely used integrated circuits

  14. Space charge effect in SQS transition in a gas counter

    International Nuclear Information System (INIS)

    Ohgaki, Hideaki; Kametani, Hitoshi; Fujita, Yasuyuki; Uozumi, Yuusuke; Ijiri, Hidenobu; Matoba, Masaru; Sakae, Takeji; Koori, Norihiko

    1990-01-01

    Systematic investigation of the gas multiplication characteristics in the transition region from proportional to SQS mode in a cylindrical proportional counter has been performed. The property of saturation of the gas multiplication factor can be reproduced using the effective electric field which is corrected for the space charge related to the positive ion density in the avalanche. Photon-mediated gas multiplication can explain the large jump phenomenon of the SQS transition. It is shown that the effective electric field in the avalanche becomes almost zero near the anode surface (Meek's streamer condition) at the 50% transition voltage and the region of its maximum moves slightly away from the anode surface. (orig.)

  15. Counter-intuitive moral judgement following traumatic brain injury.

    Science.gov (United States)

    Rowley, Dane A; Rogish, Miles; Alexander, Timothy; Riggs, Kevin J

    2017-02-07

    Several neurological patient populations, including traumatic brain injury (TBI), appear to produce an abnormally 'utilitarian' pattern of judgements to moral dilemmas; they tend to make judgements that maximize the welfare of the majority, rather than deontological judgements based on the following of moral rules (e.g., do not harm others). However, this patient research has always used extreme dilemmas with highly valued moral rules (e.g., do not kill). Data from healthy participants, however, suggest that when a wider range of dilemmas are employed, involving less valued moral rules (e.g., do not lie), moral judgements demonstrate sensitivity to the psychological intuitiveness of the judgements, rather than their deontological or utilitarian content (Kahane et al., Social Cognitive and Affective Neuroscience, 7, 2011, 393). We sought the moral judgements of 30 TBI participants and 30 controls on moral dilemmas where content (utilitarian/deontological) and intuition (intuitive/counter-intuitive) were measured concurrently. Overall TBI participants made utilitarian judgements in equal proportions to controls; disproportionately favouring utilitarian judgements only when they were counter-intuitive, and deontological judgements only when they were counter-intuitive. These results speak against the view that TBI causes a specific utilitarian bias, suggesting instead that moral intuition is broadly disrupted following TBI. © 2017 The British Psychological Society.

  16. A gas proportional scintillation counter for use in large area detector systems without photomultipliers

    International Nuclear Information System (INIS)

    Baruch, J.E.F.; Brooke, G.; Kellerman, E.W.; Bateman, J.E.; Connolly, J.F.

    1979-01-01

    The properties of a prototype gas proportional scintillation (GPS) detector module are described. The module (25X25X14cm 3 ) is intended to form the basic unit of large area (up to approximately 100 m 2 ) calorimetric cosmic ray burst detector. Ionisation from particle tracks in the module is collected onto a point electrode where the GPS signal is generated. A concave mirror focusses this point source onto the end of a fibre optic light guide. In the proposed large area detector these fibres are brought together onto a low light level TV camera which performs the readout. The prototype module has demonstrated an adequate light output for the detection of single muons by such a readout system and also permitted the investigation of the main operating parameters (gas mixture, EHT, pressure, etc) and operational requirements such as proportionality and long term stability. (Auth.)

  17. Use of the helium-3 proportional counter for neutron spectrometry; Utilisation du compteur proportionnel a helium 3 pour la spectrometrie des neutrons

    Energy Technology Data Exchange (ETDEWEB)

    Vialettes, H; Le Thanh, P [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1967-07-01

    Up to now, two methods have been mainly used for neutron spectrometry near nuclear installations: - photographic emulsion spectrometry - the so-called, 'multisphere' technique spectrometry. The first method, which is fairly difficult to apply, has a threshold energy of about 500 keV; this is a big disadvantage for an apparatus which has to be used for spectrometry around nuclear installations where the neutron radiation is very much degraded energetically. The second method does not suffer from this disadvantage but the results which it yields are only approximate. In order to extend the energy range of the neutron spectra studied with sufficient accuracy the use of a helium-3 proportional counter has been considered. This report presents the principles of operation of the helium-3 spectrometer, and the calculation methods which make it possible to take into account the two main effects tending to deform the spectra obtained: - energy absorption by the walls of the counter, - energy loss of the incident neutrons due to elastic collisions with helium-3 nuclei. As an example of the application, the shape of the neutron spectrum emitted by a polonium-lithium source is given; the results obtained are in excellent agreement with theoretical predictions. (authors) [French] Jusqu'ici deux methodes ont ete utilisees principalement pour la spectrometrie des neutrons autour des installations nucleaires: - la spectrometrie par emulsions photographiques - la spectrometrie par la technique dite des multispheres. La premiere methode, d'un emploi assez delicat presente un seuil en energie d'environ 500 keV qui est un obstacle serieux a la spectrometrie autour des installations nucleaires ou le rayonnement neutronique est tres degrade en energie. La deuxieme methode ne presente pas cet inconvenient mais les resultats qu'elle permet d'obtenir ne sont qu'approches. Pour etendre la gamme d'energie des spectres de neutrons etudies avec une precision suffisante, l'utilisation du

  18. The calculated neutron response of a sphere with the multi-counters

    International Nuclear Information System (INIS)

    Li Taosheng; Yang Lianzhen; Li Dongyu

    2004-01-01

    Based on the difference of the neutron distribution in the moderator, three position sensitive proportional counters which are perpendicular to each other are inserted into the moderator. The energy responses with six spherical moderators and six incidence directions have been calculated by MCNP4A code. The calculated results for two divided region methods in the radial of the spherical moderator have been analyzed and compared. (authors)

  19. Radiation loading effect proportional chamber on the performances

    International Nuclear Information System (INIS)

    Alekseev, T.D.; Kalinina, N.A.; Karpukhin, V.V.; Kruglov, V.V.; Khazins, D.M.

    1980-01-01

    The effect of a space charge which appears under the effect of radiation loading on counting characteristics of a proportional chamber, is experimentally investigated. Calculations are made which take into account the effect of a space charge of positive ions formed in the chamber. The investigations have been carried out on the test board which consists of a one-coordinate proportional chamber, a telescope of two scintillation counters and a collimated 90 Sr β-source. The proportional chamber has the 160x160 mm dimensions. The signal wires with the 50 μm diameter are located with the step of s=10 mm. High-voltage planes are coiled with a wire with the 100 μm diameter and a 2 mm step. The distance between high-voltage planes are 18 mm. The chamber is blown through with a gaseous mixture, its composition is 57% Ar+38% CH 4 +5% (OCH 3 ) 2 CH 2 . When carrying out measurements in wide ranges, the density of radiation loading and the amplifier threshold are changed. The experimental results show a considerable effect of radiation loading and the value of amplifier threshold on the value of a counting characteristic. This should be taken into account when estimating the performance of a proportional chamber according to board testing using radioactive sources, as conditions for investigations are usually different from those of a physical experiment on an accelerator

  20. Digital pulse-shape discrimination applied to an ultra-low-background gas-proportional counting system. First results

    International Nuclear Information System (INIS)

    Aalseth, C.E.; Day, A.R.; Fuller, E.S.; Hoppe, E.W.; Keillor, M.E.; Mace, E.K.; Myers, A.W.; Overman, C.T.; Panisko, M.E.; Seifert, A.

    2013-01-01

    A new ultra-low-background proportional counter design was recently developed at Pacific Northwest National Laboratory (PNNL). This design, along with an ultra-low-background counting system which provides passive and active shielding with radon exclusion, has been developed to complement a new shallow underground laboratory (∼30 m water-equivalent) constructed at PNNL. After these steps to mitigate dominant backgrounds (cosmic rays, external gamma-rays, radioactivity in materials), remaining background events do not exclusively arise from ionization of the proportional counter gas. Digital pulse-shape discrimination (PSD) is thus employed to further improve measurement sensitivity. In this work, a template shape is generated for each individual sample measurement of interest, a 'self-calibrating' template. Differences in event topology can also cause differences in pulse shape. In this work, the temporal region analyzed for each event is refined to maximize background discrimination while avoiding unwanted sensitivity to event topology. This digital PSD method is applied to sample and background data, and initial measurement results from a biofuel methane sample are presented in the context of low-background measurements currently being developed. (author)

  1. The application of a microstrip gas counter to energy-dispersive x-ray fluorescence analysis

    International Nuclear Information System (INIS)

    Veloso, J.F.C.A.; Santos, J.M.F. dos; Conde, C.A.N.

    1996-01-01

    Performance characteristics of a microstrip gas counter operated as a x-ray fluorescence spectrometer are reported. Gas amplification as a function of microstrip anode-cathode voltage was measured, and the breakdown threshold voltage was determined in pure xenon. The detector temporal stability and the effect of gas purity were assessed. Energy resolution and linearity, detection efficiency, and uniformity of spatial response in the 2- to 60-keV x-ray energy range were determined from the pulse-height distributions of the fluorescence x-ray spectra induced in a variety of single- and multi-element sample materials. Energy resolution similar to conventional proportional counters was achieved at 6 keV

  2. Space and power efficient hybrid counters array

    Science.gov (United States)

    Gara, Alan G [Mount Kisco, NY; Salapura, Valentina [Chappaqua, NY

    2009-05-12

    A hybrid counter array device for counting events. The hybrid counter array includes a first counter portion comprising N counter devices, each counter device for receiving signals representing occurrences of events from an event source and providing a first count value corresponding to a lower order bits of the hybrid counter array. The hybrid counter array includes a second counter portion comprising a memory array device having N addressable memory locations in correspondence with the N counter devices, each addressable memory location for storing a second count value representing higher order bits of the hybrid counter array. A control device monitors each of the N counter devices of the first counter portion and initiates updating a value of a corresponding second count value stored at the corresponding addressable memory location in the second counter portion. Thus, a combination of the first and second count values provide an instantaneous measure of number of events received.

  3. Characterisation of a ultra-miniature counter for microdosimetric measurements in a therapeutic 400 MeV/A carbon beam

    International Nuclear Information System (INIS)

    Endo, S.; Takada, M.; Ishikawa, M.; Hoshi, M.; Uehara, S.; Yamaguchi, H.; Kanai, T.; Matsufji, N.; Shizuma, K.; Onizuka, Y.

    2002-01-01

    Single event spectra of a clinical carbon beam have been measured by an ultra-miniature tissue-equivalent proportional counter (UMC). In order to cover the energy range of the Bragg peak, the incident energy of the carbon beam was degraded by aluminium plates. Single event spectra for carbon-events incident to the UMC were analysed and selected at several carbon energies using thin scintillation counters. It was found that the dose weighted lineal energy distributions have a doublet peak structure due to incident carbon beam and fragment contributions. (author)

  4. A low-level needle counter

    International Nuclear Information System (INIS)

    Fujita, Y.; Taguchi, Y.; Imamura, M.; Inoue, T.; Tanaka, S.

    1977-01-01

    A small end-window type gas-flow counter which has a sharpened needle (anode) against the end-window plane (cathode) was developed for low-level counting of β particles to the amount of less than one count per hour in solid sources of relatively high specific activity. The advantage of the needle counter for low-level work is that being of a conical shape the active volume as against the window area is small. The background count rate of 0.0092+-0.0005 cpm was obtained for a 10 mm dia needle counter operating in GM mode and in anticoincidence with a well-type NaI(Tl) guard crystal with massive shields. The counter design and the counter characteristics are presented in detail. The needle counter is simple in design, low-cost and stable in long time operation. (author)

  5. A long liquid Cherenkov counter for 300 to 460 MeV/c pion beams

    International Nuclear Information System (INIS)

    Zavrtanik, D.; Sever, F.; Plesko, M.; Music, M.; Kernel, G.

    1984-01-01

    A long liquid Cherenkov counter has been used to measure the proportion of muons in positive and negative pion beams in the momentum range between 300 and 460 MeV/c. A nine-parameter function fits all the spectra well. The data show a smooth dependence on incident momenta and agree with calculations of pion and muon pulse heights. (orig.)

  6. Counter-discourse in Zimbabwean literature

    NARCIS (Netherlands)

    Mangena, Tendai

    2015-01-01

    Counter-Discourse in Zimbabwean Literature is a study of specific aspects of counter-discursive Zimbabwean narratives in English. In discussing the selected texts, my thesis is based on Terdiman’s (1989) the postcolonial concept of counter-discourse. In Zimbabwean literature challenges to a dominant

  7. Efficiency simulation of long neutron counter

    International Nuclear Information System (INIS)

    Hu Qingyuan; Li Bojun; Zhang De; Guo Hongsheng; Wang Dong; Yang Gaozhao; Si Fenni; Liu Jian

    2008-01-01

    In order to achieve the high efficiency and uniform sensitivity for neutrons with widely different energies, the efficiency of long boron trifluoride proportional counter imbedded in polyethylene moderator was simulated by MCNP code. The result shows that detective efficiency would increase with increasing moderator radius and response curve at higher energy would be ameliorated through adjusting the thickness of front moderator. Also we calculated the relative efficiencies for different energy of a detector whose efficiencies were calibrated on an accelerator. The simulated efficiency for D-D neutrons (2.4 MeV) is 75% of the efficiency for D-T neutrons (14.1 MeV), which is approximately agreed with experimental data, 61%. The validity of the simulated model was proved by the consistent results between calculation and experiment data. (authors)

  8. Efficiency determination of whole-body counters by Monte Carlo method, using a microcomputer

    International Nuclear Information System (INIS)

    Fernandes Neto, J.M.

    1987-01-01

    A computing program using Monte Carlo method for calculate the whole efficiency of distributed radiation counters in human body is developed. A simulater of human proportions was used, of which was filled with a known and uniform solution containing a quantity of radioisopes. The 99m Tc, 131 I and 42 K were used in this experience, and theirs activities compared by a liquid scintillator. (C.G.C.) [pt

  9. The parallel plate avalanche counter: a simple, rugged, imaging X-ray counter

    International Nuclear Information System (INIS)

    Joensen, K.D.; Budtz-Joergensen, C.; Bahnsen, A.; Madsen, M.M.; Olesen, C.; Schnopper, H.W.

    1995-01-01

    A two-dimensional parallel gap proportional counter has been developed at the Danish Space Research Institute. Imaging over the 120 mm diameter active area is obtained using the positive ion component of the avalanche signals as recorded by a system of wedge- and strip-electrodes. An electronically simple, but very effective background rejection is obtained by using the fast electron component of the avalanche signal. Gas gains up to 8x10 5 have been achieved. An energy-resolution of 16% and a sub-millimeter spatial resolution have been measured at 5.9 keV for an operating gas gain of 10 5 . In principle, the position coordinates are linear functions of electronic readouts. The present model, however, exhibits non-linearities, caused by imperfections in the wedge and strip-electrode pattern. These non-linearities are corrected by using a bilinear correction algorithm. We conclude that the rugged construction, the simple electronics, the effectiveness of the background rejection and the actual imaging performance makes this a very attractive laboratory detector for low and intermediate count rate imaging applications. ((orig.))

  10. What is Counter-Enlightenment?

    OpenAIRE

    Darrin M. McMahon

    2017-01-01

    This article counters recent suggestions that there was no such thing as a “Counter-Enlightenment” or “Counter-Enlightenments,” and that such terms ought thus to be abandoned.   While acknowledging inevitable difficulties with the terms, the article argues that there can be no doubting the reality.   European countries faced a variety of vehement and self-conscious movements that defined themselves precisely through their opposition to what they took to be the corrosive effects of the Enlight...

  11. A portable neutron coincidence counter

    Energy Technology Data Exchange (ETDEWEB)

    Peurrung, A.J.; Bowyer, S.M.; Craig, R.A.; Dudder, G.B.; Knopf, M.A.; Panisko, M.E.; Reeder, P.L.; Stromswold, D.C.; Sunberg, D.S.

    1996-11-01

    Pacific Northwest National Laboratory has designed and constructed a prototype portable neutron coincidence counter intended for use in a variety of applications, such as the verification and inspection of weapons components, safety measurements for novel and challenging situations, portable portal deployment to prevent the transportation of fissile materials, uranium enrichment measurements in hard-to-reach locations, waste assays for objects that cannot be measured by existing measurement systems, and decontamination and decommissioning. The counting system weighs less than 40 kg and is composed of parts each weighing no more than 5 kg. In addition, the counter`s design is sufficiently flexible to allow rapid, reliable assembly around containers of nearly arbitrary size and shape. The counter is able to discern the presence of 1 kg of weapons-grade plutonium within an ALR-8 (30-gal drum) in roughly 100 seconds and 10 g in roughly 1000 seconds. The counter`s electronics are also designed for maximum adaptability, allowing operation under a wide variety of circumstances, including exposure to gamma-ray fields of 1 R/h. This report provides a detailed review of the design and construction process. Finally, preliminary experimental measurements that confirm the performance capabilities of this counter are discussed. 6 refs., 18 figs., 3 tabs.

  12. CEDAR counter (internal part)

    CERN Multimedia

    CERN PhotoLab

    1976-01-01

    Here on the mounting bench. The counter is a differential Cerenkov, corrected for chromaticity, able to differentiate pions from kaons up to 350 GeV. Counters of this type were used in all SPS hadron beams.

  13. Whole Body Counters (rev.)

    Energy Technology Data Exchange (ETDEWEB)

    Woodburn, John H. [Walter Johnson High School, Rockville, MD; Lengemann, Frederick W. [Cornell University

    1967-01-01

    Whole body counters are radiation detecting and measuring instruments that provide information about the human body. This booklet describes different whole body counters, scientific principles that are applied to their design, and ways they are used.

  14. 4{pi} proportional counter for absolute measurement of {beta}-emitters; Compteur 4{pi} proportionnel destine a la mesure absolue d'emetteurs {beta}

    Energy Technology Data Exchange (ETDEWEB)

    Perolat, J P; Laine, M [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1967-07-01

    The 4{pi} counter is commonly used to measure the activity of {beta} sources, the one we describe does not advance a new conception but the issue of several years of investigations. The apparatus presents good performances about the qualities commonly required in that kind of counter: detection efficiency, plateau and dead time. Moreover technical characteristics give a great flexibility in use, particularly a possibility of adaptation in a {beta},{gamma} coincidence unit. (authors) [French] Le compteur 4{pi} proportionnel est couramment, utilise pour mesurer l'activite de sources {beta}, celui que nous decrivons ne represente pas une conception nouvelle, mais plutot l'aboutissement de plusieurs annees d'etudes. Cette installation presente des performances satisfaisantes en ce qui concerne les qualites habituellement requises dans ce type de compteur: l'efficacite de detection, le palier et le temps mort. En outre, certaines caracteristiques techniques qui lui sont propres lui conferent une grande souplesse d'utilisation, en particulier la possibilite d'adaptation a un ensemble de mesures par coincidences 4{pi} {beta} {gamma}. (auteurs)

  15. Calibration tests and use of a Nicolet/Xentronics imaging proportional chamber mounted on a conventional source for protein crystallography

    Energy Technology Data Exchange (ETDEWEB)

    Derewenda, Z; Helliwell, J R

    1989-04-01

    The results are presented of calibration tests and several single-crystal X-ray data collection experiments undertaken with a Nicolet/Xentronics Imaging Proportional Counter mounted on a conventional X-ray source. Considerable attention has been given to system optimization in collaboration with Nicolet, and this has led to a performance of high quality. (orig.).

  16. Over-the-Counter Medicines

    Science.gov (United States)

    Over-the-counter (OTC) medicines are drugs you can buy without a prescription. Some OTC medicines relieve aches, pains and itches. ... medicine is safe enough to sell over-the-counter. Taking OTC medicines still has risks. Some interact ...

  17. In-vivo radiation counter

    International Nuclear Information System (INIS)

    Pollard, D.E.

    1983-01-01

    This patent specification describes a radiation counter utilizing at least one detector for sensing radiation from a living body. The radiation counter also includes an aperture for forming a corridor between the body and the detector. A shield outside the corridor prevents passage of background radiation through the corridor and gaining access to the detector. The counter also includes a device for isolating a selected portion of the body from the corridor such that radiation counting is restricted to a region of the body through a separate detector. The corridor formation permits a user to stand in an upright position while the detector and detectors are able to separately monitor different sections of the body. The radiation counter overcomes the problem of obtaining accurate and quick measurements or radiation doses sustained by a large group of persons. (author)

  18. Rapid actinide analysis method coupling liquid chromatography/ICP-MS and "9"0Sr gas proportional counter in post-accidental situation environmental samples

    International Nuclear Information System (INIS)

    Habibi, Azza

    2015-01-01

    The present study follows the Fukushima power plant accident and aimed to develop an analytical method to achieve, during an emergency situation, a rapid identification and quantification of alpha and beta emitters in environmental samples. The first step of this study allowed us to list the alpha and beta emitters which can be released in the environment in case of a nuclear accident. The second step aimed towards the development of a rapid analysis method to quantify 17 radionuclides of U, Th, Pu, Am, Np and Sr. The main objective was the automation of the radiochemical separation step and its coupling for the measurement. The separation is performed using columns containing extraction resins, namely TEVA, TRU and Sr. The measurement is performed using an ICP-MS (inductively coupled plasma mass spectrometry) and in some cases a gas proportional counter to quantify radiostrontium ("8"9Sr and "9"0Sr). Excellent figures of merit were obtained, off line, with water (tap, river and sea water) and solid matrices (soil and aerosol filters), after a micro-wave digestion or an alkaline fusion dissolution followed by a Ca_3(PO_4)_2 coprecipitation. The proposed analytical strategy showed yields between 70 % and 100 % and standard deviations between 5 % and 10 %. The newly developed separation method was then automated and coupled on-line to ICP-MS. The operating parameters were optimized using a design of experiments and the results were processed with Minitab. The optimized automated separation coupled on-line to the ICP-MS allows the rapid quantification, in 1.5 h per sample, of U, Th, Pu, Am, Np and Sr with detection limits gain as high as 20 times for artificial radionuclide. (author)

  19. Permanently calibrated interpolating time counter

    International Nuclear Information System (INIS)

    Jachna, Z; Szplet, R; Kwiatkowski, P; Różyc, K

    2015-01-01

    We propose a new architecture of an integrated time interval counter that provides its permanent calibration in the background. Time interval measurement and the calibration procedure are based on the use of a two-stage interpolation method and parallel processing of measurement and calibration data. The parallel processing is achieved by a doubling of two-stage interpolators in measurement channels of the counter, and by an appropriate extension of control logic. Such modification allows the updating of transfer characteristics of interpolators without the need to break a theoretically infinite measurement session. We describe the principle of permanent calibration, its implementation and influence on the quality of the counter. The precision of the presented counter is kept at a constant level (below 20 ps) despite significant changes in the ambient temperature (from −10 to 60 °C), which can cause a sevenfold decrease in the precision of the counter with a traditional calibration procedure. (paper)

  20. Portable microcomputer controlled radiation counter

    International Nuclear Information System (INIS)

    Mason, E.W.; Weber, J.M.

    1984-01-01

    A portable microcomputer controlled counter for use as a radiation counter is described. The counter uses digital processing of input pulses from a radiation detector. The number of counts received by the microcomputer per unit time is used to calculate a value for display using a calibration factor obtained during physical calibration of the instrument with a radiation source or with a pulse generator. The keyboard is used to enter calibration points. The number of calibration points which may be entered depends on the degree of accuracy desired by the user. The high voltage generator which drives the detector is triggered by pulses from the microcomputer in relation to the count rate. After processing the count, the resulting count rate or dose rate is displayed on the liquid crystal display. The counter is autoranging in which the decimal point is shifted as necessary by the microcomputer. The units displayed are determined by the user by means of a multiposition switch. Low battery and an overrange condition are displayed. An interface is provided via a connector to allow parallel transmission of data to peripheral devices. Low battery power consumption is featured. The counter is capable of providing more accurate readings than currently available counters

  1. Energy performance of an innovative liquid desiccant dehumidification system with a counter-flow heat and mass exchanger using potassium formate

    DEFF Research Database (Denmark)

    Jradi, Muhyiddine; Riffat, Saffa

    2014-01-01

    An innovative micro-scale liquid desiccant dehumidification system is numerically investigated. The liquid desiccant dehumidification unit employs a counter-flow low-cost and efficient heat and mass exchange core, improving the thermal performance and eliminating desiccant carryover...... that the dehumidifier effectiveness is directly proportional to the intake air temperature, intake air relative humidity and liquid desiccant flow rate where the effectiveness is inversely proportional to the intake air velocity and the heat exchanger air channel height....

  2. Process for the automatic compensation of spectral displacement based on quenching processes in a liquid scintillation counter

    International Nuclear Information System (INIS)

    Nather, R.E.

    1978-01-01

    In measurements in a liquid scintillation counter, the tritium or C 14 isotope to be examined is situated in a scintillator solution. It is excited according to the energy of the β particle to emit light. An electrical signal is proportional to the light signal, and from the former, selective counting in the β spectrum can be undertaken in an impulse height analyser. The influence of the quenching effects by colour quenching or chemical quenching would reduce the gain of the counter. To compensate for the displacement of the spectrum, the required adjustment of a system parameter is carried out by calibration with a sample of low quenching effect. The calibration process is directly set for the energy end-point of the spectrum. Well known processes can be used to determine the quenching effect of the quenching represented by the sample. For example, the system parameters can be the discriminator level of the counter window. (DG) 891 HP [de

  3. What is Counter-Enlightenment?

    Directory of Open Access Journals (Sweden)

    Darrin M. McMahon

    2017-02-01

    Full Text Available This article counters recent suggestions that there was no such thing as a “Counter-Enlightenment” or “Counter-Enlightenments,” and that such terms ought thus to be abandoned.   While acknowledging inevitable difficulties with the terms, the article argues that there can be no doubting the reality.   European countries faced a variety of vehement and self-conscious movements that defined themselves precisely through their opposition to what they took to be the corrosive effects of the Enlightenment.  In the process, they defined the main terms of an enduring vision of the world that we now associate with the Right.

  4. Nuclear timer/counter

    International Nuclear Information System (INIS)

    Wuthayavanich, S.

    1978-01-01

    This thesis represents the development of a Timer/COUNTER compatible to the standard Nuclear Instrument Module Specifications. The unit exhibits high accuracy, light weight and ease of maintenance. The unit also has a built-in precision discriminator to discriminate unwanted signals that may cause interference in counting. With line frequency time base the timer can be preset in steps from 0.1 sec. to 9 x 10 5 min. The counter with six digits miniature display and an overflow output has a maximum counting rate of 10 MHz. The accumulated counting data can be transferred to a teletype or printer for hard copy printout with the aid of ORTEC 777 Line Printer or 432 A Print-out Control or any print out interface with input compatible to the print output of the Timer/Counter. Owing to its NIM compatibility the unit is directly powered by the NIM power supply

  5. The first CEDAR counter

    CERN Multimedia

    CERN PhotoLab

    1976-01-01

    The first differential Cerenkov counter with chromatic corrections (called CEDAR) successfully tested at the PS in July 75. These counters were used in the SPS hadronic beams for particle identification. Some of the eight photomultipliers can be seen: they receive the light reflected back through the annular diaphragm. René Maleyran stands on the left.

  6. MANTEL-HAENSZEL TYPE ESTIMATORS FOR THE COUNTER-MATCHED SAMPLING DESIGN IN NESTED CASE-CONTROL STUDY

    OpenAIRE

    Fujii, Yoshinori; Zhang, Zhong-Zhan; 藤井, 良宜

    2001-01-01

    We are concerned with a counter-matched nested case-control study. Assuming the proportional hazards model, the Mantel-Haenszel estimators of hazard rates are presented in two situations. The proposed estimators can be calculated without estimating the nuisance parameter. Consistent estimators of the variance of the proposed hazard rate estimators are also developed. We compare these estimators to the maximum partial likelihood estimators in the asymptotic variance. The methods are illustrate...

  7. Large Area X-ray Proportional Counter (LAXPC) Instrument on AstroSat and Some Preliminary Results from its performance in the orbit

    OpenAIRE

    Agrawal, P. C.; Yadav, J. S.; Antia, H. M.; Dedhia, Dhiraj; Shah, P.; Chauhan, Jai Verdhan; Manchanda, R. K.; Chitnis, V. R.; Gujar, V. M.; Katoch, Tilak; Kurhade, V. N.; Madhwani, P.; Manojkumar, T. K.; Nikam, V. A.; Pandya, A. S.

    2017-01-01

    Large Area X-ray Propositional Counter (LAXPC) instrument on AstroSat is aimed at providing high time resolution X-ray observations in 3 to 80 keV energy band with moderate energy resolution. To achieve large collecting area, a cluster of three co-aligned identical LAXPC detectors, is used to realize an effective area in access of about 6000 cm2 at 15 keV. The large detection volume of the LAXPC detectors, filled with xenon gas at about 2 atmosphere pressure, results in detection efficiency g...

  8. Fiber-Optic Monitoring System of Particle Counters

    Directory of Open Access Journals (Sweden)

    A. A. Titov

    2016-01-01

    Full Text Available The article considers development of a fiber-optic system to monitor the counters of particles. Presently, optical counters of particles, which are often arranged at considerable distance from each other, are used to study the saltation phenomenon. For monitoring the counters, can be used electric communication lines.However, it complicates and raises the price of system Therefore, we offered a fiber-optic system and the counter of particles, free from these shortcomings. The difference between the offered counter of particles and the known one is that the input of radiation to the counter and the output of radiation scattering on particles are made by the optical fibers, and direct radiation is entered the optical fiber rather than is delayed by a light trap and can be used for lighting the other counters thereby allowing to use their connection in series.The work involved a choice of the quartz multimode optical fiber for communication, defining the optical fiber and lenses parameters of the counter of particles, and a selection of the radiation source and the photo-detector.Using the theory of light diffraction on a particle, a measuring range of the particle sizes has been determined. The system speed has been estimated, and it has been shown that a range of communication can reach 200km.It should be noted that modulation noise of counters of particles connected in series have the impact on the useful signal. To assess the extent of this influence we have developed a calculation procedure to illustrate that with ten counters connected in series this influence on the signal-to-noise ratio will be insignificant.Thus, it has been shown that the offered fiber-optic system can be used for monitoring the counters of particles across the desertified territories. 

  9. Counter-Narratives and the Unrehearsed Stories Counter-Terrorists Unwittingly Produce

    Directory of Open Access Journals (Sweden)

    Beatrice de Graaf

    2010-11-01

    Full Text Available Governments produce both deliberate and involuntary (and less conscious narratives when countering terrorism. The thesis of this article is that such unintended messages can be much more powerful and consequential than is realized; in fact, they can completely contradict the intended official 'counter-narrative'. To substantiate this hypothesis, the author looks at the experience of the German Federal Republic in the 1970s and beyond when state and society were confronted with the Red Army Faction (RAF and similar left-wing "revolutionaries" like those of the 2nd of June Movement or the Red Zora.

  10. Real-time {sup 90}Sr Counter

    Energy Technology Data Exchange (ETDEWEB)

    Kaneko, Naomi; Kawai, Hideyuki; Kodama, Satoshi; Kobayashi, Atsushi; Tabata, Makoto; Ito, Hiroshi [Graduate School of Science, Chiba University, Chiba, (Japan); Han, Soorim [Graduate School of Science, Chiba University, Chiba, (Japan); National Institute of Radiological Science, Chiba, (Japan)

    2015-07-01

    Radioisotopes have been emitted around Japan due to a nuclear accident at the Fukushima Daiichi nuclear power station in March 2011. A problem is the contaminated water including the atomic nucleus which relatively has a long half- life time and soluble such as {sup 90}Sr, {sup 137}Cs. Internal exposures by {sup 90}Sr are more dangerous than {sup 137}Cs's because Sr has effective half-life time of 18 years and property of accumulation in a born. We have developed real-time {sup 90}Sr counter which is sensitive beta-ray of maximum kinematic energy of 2.28 MeV from {sup 90}Sr and insensitive of beta-ray of maximum kinematic energy of 1.17 MeV and gamma-ray from {sup 90}Sr by Cherenkov detection. This counter composes of Cerenkov counter, trigger scintillation counter and veto counter. Silica aerogel for Cherenkov counter can obtain refractive index between 1.017 and 1.049 easily. And wavelength shifting fiber (WLSF) is used as a light guide for extending effective area and producing lower cost. A mechanism of the identification of {sup 90}Sr is explained in following. In case of {sup 90}Sr, when the trigger counter reacts on the beta-ray from {sup 90}Sr, aerogel emits the Cherenkov light and WLSF reacts and read the Cherenkov light. On the other hand, in case of {sup 137}Cs, the trigger counter reacts on the beta-ray, aerogel stops the beta- ray and Cherenkov light is not emitted. Therefore, aerogel has a function as a radiator and shielding material. the gamma-ray is not reacted on the lower density detector. Cosmic rays would be also reacted by the veto counter. A prototype counter whose the effective area is 30 cm x 10 cm was obtained (2.0±1.2){sup 3} of mis-identification as {sup 137}Cs/{sup 90}Sr. Detection limit in the surface contamination inspection depends on measurement time and effective area mainly. The sensitivity of wide range, 10{sup -2} - 10{sup 4} Bq/cm{sup 2}, is obtained by adjustment of detection level in circuit of this counter. A lower

  11. Plea and counter-plea

    International Nuclear Information System (INIS)

    1979-06-01

    The bulk of papers written during the hearing 'Plea and counter-plea', the so-called 'Gorleben hearing', which was held from 28th March until 3rd April 1979, comprises ca. 4,200 pages. It consists of the written comments put forward by the critics of nuclear energy, the minutes of the hearing as well as the supplementary statements of the counter-critics. This report is trying to confront those essential objections made by the critics which put in doubt the feasibility of a fuel-cycle centre with regard to safety engineering with the facts which are considered correct from the view of the DWK. The oral and written explanations of the counter-critics are particularly referred to in this debate. (orig./HP) [de

  12. Multiple channel programmable coincidence counter

    Science.gov (United States)

    Arnone, Gaetano J.

    1990-01-01

    A programmable digital coincidence counter having multiple channels and featuring minimal dead time. Neutron detectors supply electrical pulses to a synchronizing circuit which in turn inputs derandomized pulses to an adding circuit. A random access memory circuit connected as a programmable length shift register receives and shifts the sum of the pulses, and outputs to a serializer. A counter is input by the adding circuit and downcounted by the seralizer, one pulse at a time. The decoded contents of the counter after each decrement is output to scalers.

  13. Aerogel Cherenkov Counters of the KEDR Detector

    CERN Document Server

    Ovtin, I V; Barnyakov, M Y; Bobrovnikov, V S; Buzykaev, A R; Danilyuk, A F; Katcin, A A; Kononov, S A; Kravchenko, E A; Kuyanov, I A; Onuchin, A P; Rodiakin, V A

    2017-01-01

    The particle identification system of the KEDR detector is based on aerogel threshold Cherenkov counters called ASHIPH counters. The system consists of 160 counters arranged in two layers. An event reconstruction program for the ASHIPH system was developed. The position of each counter relative to the tracking system was determined using cosmic muons and Bhabha events. The geometric efficiency of the ASHIPH system was verified with Bhabha events. The efficiency of relativistic particle detection was measured with cosmic muons. A π/K separation of 4δ in the momentum range 0.95 −1.45 GeV/c was confirmed. A simulation program for the ASHIPH counters has been developed.

  14. Crate counter for normal operating loss

    International Nuclear Information System (INIS)

    Harlan, R.A.

    A lithium-loaded zinc sulfide scintillation counter to closely assay plutonium in waste packaged in 1.3 by 1.3 by 2.13m crates was built. In addition to assays for normal operating loss accounting, the counter will allow safeguards verification immediately before shipment of the crates for burial. The counter should detect approximately 10 g of plutonium in 1000 kg of waste

  15. An introduction to automatic radioactive sample counters

    International Nuclear Information System (INIS)

    1980-01-01

    The subject is covered in chapters, entitled; the detection of radiation in sample counters; nucleonic equipment; liquid scintillation counting; basic features of automatic sample counters; statistics of counting; data analysis; purchase, installation, calibration and maintenance of automatic sample counters. (U.K.)

  16. Monte Carlo calculations and experimental results of Bonner spheres systems with a new cylindrical Helium-3 proportional counter

    CERN Document Server

    Müller, H; Bouassoule, T; Fernández, F; Pochat, J L; Tomas, M; Van Ryckeghem, L

    2002-01-01

    The experimental results on neutron energy spectra, integral fluences and equivalent dose measurements performed by means of a Bonner sphere system placed inside the containment building of the Vandellos II Nuclear Power Plant (Tarragona, Spain) are presented. The equivalent dose results obtained with this system are compared to those measured with different neutron area detectors (Berthold, Dineutron, Harwell). A realistic geometry model of the Bonner sphere system with a new cylindrical counter type 'F' (0,5NH1/1KI--Eurisys Mesures) and with a set of eight polyethylene moderating spheres is described in detail. The response function in fluence of this new device, to mono-energetic neutrons from thermal energy to 20 MeV, is calculated by the MCNP-4B code for each moderator sphere. The system has been calibrated at IPSN Cadarache facility for ISO Am-Be calibrated source and thermal neutron field, then the response functions were confirmed by measurements at PTB (Germany) for ISO recommended energies of mono-e...

  17. Multiwire proportional chambers with a high spatial resolution for X radiation detection and localization

    International Nuclear Information System (INIS)

    Algre, J.-L.

    1975-01-01

    A multiwire proportional counter, with a high spatial resolution has been developed, and some basic characteristics of this type of detector specified. A method of calculating the potential and consequently the field at each point of the volume limited by the counter was defined. The method allows the problems of the outer wires to be solved, and the consequences of a wire displacement predicted. The analysis of the pulses observed on both cathode and anode showed that they were hardly formed from the only ion migration from the cathode to the anode. An estimation of the formation time duration established that in argon mixtures with a low percentage of methane, Ar + ions are in majority. Then it can be predicted that anode wires are not to be spaced by less than 1mm when a conventional electronics is used. The study of the multiplication factor as a function of the main geometric parameters of the counter gave a relation between the multiplication coefficient and the geometric parameters of the chamber; consequently the optimal operation conditions can be predicted. Especially, the diameter of the multiplying wires must be as weak as possible to improve the energy resolution of the detector. A localization method showed that an interpolation may be done between two wires so that, with 1mm spaced wires, the two-dimensional position of an event can be determined with a resolution better than 0.5mm for both directions [fr

  18. The counter ion: expanding excipient functionality

    Directory of Open Access Journals (Sweden)

    Shireesh Apte

    2011-06-01

    Full Text Available Excipients have increasingly become 'enablers' of drug delivery and efficacy rather than passive bystanders. Advances in pharmaceutical technology have enabled the ability to deliver specific counter ions (in the form of the counter ion containing excipient and the API simultaneously to preselected targets in the body. This, coupled with a near universal mechanism of columbic interactions that determine the [API- counter ion] efficacy, can be harnessed to exploit this hitherto unavailable or unrecognized enabling mechanism. New excipients may be assembled by a near inexhaustible supply of different permutations of counter ions and their judicious use in specific situations could potentially drive a renaissance in excipient innovation (and drug delivery and efficacy despite regulatory stagnation.

  19. Signal shaping and tail cancellation for gas proportional detectors at high counting rates

    International Nuclear Information System (INIS)

    Boie, R.A.; Hrisoho, A.T.; Rehak, P.

    1982-01-01

    A low noise, wide bandwidth preamplifier and signal processing filter were developed for high counting rate proportional counters. The filter consists of a seven pole Gaussian integrator with symmetrical weighting function and continuously variable shaping time, tausub(s), of 8-50 ns (fwhm) preceded by a second order pole/zero circuit which cancels the long (1/t) tails of the chamber signals. The preamplifier is an optimized common base input design with 2 ns rise time and an equivalent noise input charge < 2000 r.m.s. electrons, when connected to a chamber with 10 pF capacitance and at a filtering time, tausub(s), of 10 ns. (orig.)

  20. Rapid method for determining Sr-89 and Sr-90 using Cherenkov and proportional counting; Schnellmethode zur Bestimmung von SR-89 und SR-90 durch Cerenkov- und Proportionalzaehlermessungen

    Energy Technology Data Exchange (ETDEWEB)

    Lange, S.; Wende, C.; Schwokowski, R.; Alisch-Mark, M.; Abraham, A.; Heinrich, T. [Staatliche Betriebsgesellschaft fuer Umwelt und Landwirtschaft, Radebeul (Germany)

    2016-07-01

    A rapid method for determining Sr-89 and Sr-90 in water, milk and biological samples has been developed and tested. After sample preparation strontium is separated by extraction chromatography using Sr resin. Eluate is divided and transfered to LSC vial and filter paper by SrCO{sub 3} precipitation. A Hidex 300 SL TDCR liquid scintillation counter and Thermo Fisher low level proportional counter have been used. Chemical yield of Sr-85 tracer is determined by Gamma spectroscopy. Uncertainty budget, decision threshold and detection limit are calculated in accordance with GUM and ISO 11929.

  1. Counter-cryptanalysis

    NARCIS (Netherlands)

    M.M.J. Stevens (Marc); R. Canetti; J.A. Garay

    2013-01-01

    textabstractWe introduce \\emph{counter-cryptanalysis} as a new paradigm for strengthening weak cryptographic primitives against cryptanalytic attacks. Redesigning a weak primitive to more strongly resist cryptanalytic techniques will unavoidably break backwards compatibility. Instead,

  2. Over-the-counter codeine use in Iceland

    DEFF Research Database (Denmark)

    Almarsdóttir, A B; Grimsson, A

    2000-01-01

    BACKGROUND: The objective of this study was to test the assumption that liberalizing community pharmacy ownership in Iceland would lead to increased irrational use of over-the-counter pain relievers containing codeine. METHODS: Based on this assumption we built and tested a model using an interru......BACKGROUND: The objective of this study was to test the assumption that liberalizing community pharmacy ownership in Iceland would lead to increased irrational use of over-the-counter pain relievers containing codeine. METHODS: Based on this assumption we built and tested a model using...... an interrupted time series design that contrasts the monthly sales data for over-the-counter pain relievers containing codeine before and after the legislation took effect. RESULTS: The total use of over-the-counter pain relievers containing codeine as well as those containing paracetamol and codeine has risen...... leads to irrational use of over-the-counter medicines is not substantiated in the case of over-the-counter pain relievers containing codeine....

  3. Optimization of simultaneous tritium–radiocarbon internal gas proportional counting

    Energy Technology Data Exchange (ETDEWEB)

    Bonicalzi, R. M.; Aalseth, C. E.; Day, A. R.; Hoppe, E. W.; Mace, E. K.; Moran, J. J.; Overman, C. T.; Panisko, M. E.; Seifert, A.

    2016-03-01

    Specific environmental applications can benefit from dual tritium and radiocarbon measurements in a single compound. Assuming typical environmental levels, it is often the low tritium activity relative to the higher radiocarbon activity that limits the dual measurement. In this paper, we explore the parameter space for a combined tritium and radiocarbon measurement using a methane sample mixed with an argon fill gas in low-background proportional counters of a specific design. We present an optimized methane percentage, detector fill pressure, and analysis energy windows to maximize measurement sensitivity while minimizing count time. The final optimized method uses a 9-atm fill of P35 (35% methane, 65% argon), and a tritium analysis window from 1.5 to 10.3 keV, which stops short of the tritium beta decay endpoint energy of 18.6 keV. This method optimizes tritium counting efficiency while minimizing radiocarbon beta decay interference.

  4. Basic Research Needs for Countering Terrorism

    Energy Technology Data Exchange (ETDEWEB)

    Stevens, W.; Michalske, T.; Trewhella, J.; Makowski, L.; Swanson, B.; Colson, S.; Hazen, T.; Roberto, F.; Franz, D.; Resnick, G.; Jacobson, S.; Valdez, J.; Gourley, P.; Tadros, M.; Sigman, M.; Sailor, M.; Ramsey, M.; Smith, B.; Shea, K.; Hrbek, J.; Rodacy, P.; Tevault, D.; Edelstein, N.; Beitz, J.; Burns, C.; Choppin, G.; Clark, S.; Dietz, M.; Rogers, R.; Traina, S.; Baldwin, D.; Thurnauer, M.; Hall, G.; Newman, L.; Miller, D.; Kung, H.; Parkin, D.; Shuh, D.; Shaw, H.; Terminello, L.; Meisel, D.; Blake, D.; Buchanan, M.; Roberto, J.; Colson, S.; Carling, R.; Samara, G.; Sasaki, D.; Pianetta, P.; Faison, B.; Thomassen, D.; Fryberger, T.; Kiernan, G.; Kreisler, M.; Morgan, L.; Hicks, J.; Dehmer, J.; Kerr, L.; Smith, B.; Mays, J.; Clark, S.

    2002-03-01

    To identify connections between technology needs for countering terrorism and underlying science issues and to recommend investment strategies to increase the impact of basic research on efforts to counter terrorism.

  5. A fast photo-counter with multi-level buffers

    International Nuclear Information System (INIS)

    Peng Hu; Zhou Peiling; Yao Kun; Guo Guangcan

    1992-01-01

    Digital Photon Correlator (DPC) is composed of a Photo-counter and a data processing unit. The performance of Photo-counter in data acquisition system has a direct influence on data processing. The Photo-counter with fast carry designed here has multi-level buffers. Photon pulses can be correctly and dynamically recorded by the Photo-counter and processed by a single chip computer

  6. Counter-responses as organizers in adolescent analysis and therapy.

    Science.gov (United States)

    Richmond, M Barrie

    2004-01-01

    The author introduces Counter-response as a phenomological term to replace theory-burdened terms like counter-transference, counter-identification, and counter-resistance. He discusses the analyst's use of self (drawing on the comparison with Winnicott's use of the object) in processing the expectable destabilizing counter-reactions that occur in working therapeutically with disturbed adolescents and their parents. Further; he discusses the counter-reaction to the patient's narrative, acting-out, and how re-enactments can serve as an organizer for understanding the patient's inner life when the analyst formulates his/her counter-response. Emphasis is placed on the therapist forming his or her own narrative with the adolescent that takes into account the evoked counter-reaction. For this purpose, the author recommends the use of a combined counter-response and metaphor-orienting perspective to acknowledge and work with the denial, illusions, reversal of perspective, and catastrophic anxieties experienced with these adolescents. The counter-response perspective permits the emergence of the disturbed adolescent's novel narrative; however, since these experiences can be destabilizing or disruptive, the author also recommends the use of a personal metaphor to anticipate the reluctance to examining, processing, and formulating the analyst's dysphoric counter-reaction. With the use of the counter-response, the analyst's therapeutic ideal is to achieve a more optimal balance between using accepted narrative theories and exploring novel enactment experiences. His swimming metaphor stratagem is designed to keep the analyst in these difficult encounters.

  7. High-speed parallel counter

    International Nuclear Information System (INIS)

    Gus'kov, B.N.; Kalinnikov, V.A.; Krastev, V.R.; Maksimov, A.N.; Nikityuk, N.M.

    1985-01-01

    This paper describes a high-speed parallel counter that contains 31 inputs and 15 outputs and is implemented by integrated circuits of series 500. The counter is designed for fast sampling of events according to the number of particles that pass simultaneously through the hodoscopic plane of the detector. The minimum delay of the output signals relative to the input is 43 nsec. The duration of the output signals can be varied from 75 to 120 nsec

  8. A multi purpose 4 π counter spherical ionization chamber type

    International Nuclear Information System (INIS)

    Calin, Marian Romeo; Calin, Adrian Cantemir

    2004-01-01

    A pressurized ionization chamber detector able to measure radioactive sources in internal 2π or 4π geometry was built in order to characterize alpha and beta radioactive sources, i.e. to calibrate these sources by relative method and to test the behavior of gas mixtures in pressurized-gas radiation detectors. The detector we made is of spherical shape and works by collecting in a uniform electric field the ionization charges resulting from the interaction of ionizing radiation with gas in the sensitive volume of the chamber. An ionizing current proportional to the activity of the radioactive source to be measured is obtained. In this paper a gas counter with a spherical symmetry is described. This detector can work in a very satisfactory manner, either as a flow counter or as a ionization chamber reaching in the latter case a good α pulse height resolution, even with large emitting sources. Calculations are made in order to find the dependence of the pulse shape on the direction of emission of an α-particle by a point source in the chamber (finite track). A good agreement is found between these calculations and the experimental tests performed, which show that this dependence can be employed in high efficiency measurements of angular α-γ correlations. (authors)

  9. The Micro Trench Gas Counter

    International Nuclear Information System (INIS)

    Schmitz, J.

    1991-07-01

    A novel design is presented for a gas avalanche chamber with micro-strip gas readout. While existing gaseous microstrip detectors (Micro-strip Gas Counters, Knife edge chambers) have a minimum anode pitch of the order of 100 μm, the pitch of the discussed Micro Trench Gas Counter goes down to 30-50 μm. This leads to a better position resolution and two track separation, and a higher radiation resistivity. Its efficiency and signal speed are expected to be the same as the Microstrip Gas Counter. The energy resolution of the device is expected to be equal to or better than 10 percent for the 55 Fe peak. Since the anode strip dimensions are larger than those in a MSGC, the device may be not as sensitive to discharges and mechanical damage. In this report production of the device is briefly described, and predictions on its operation are made based on electric field calculations and experience with the Microstrip Gas Counter. The authors restrict themselves to the application in High Energy Physics. (author). 10 refs.; 9 figs

  10. The 'miniskirt' counter array at CDF II

    International Nuclear Information System (INIS)

    Artikov, A.; Budagov, Yu.; Bellettini, G.

    2002-01-01

    Muon detection is fundamental to many of the interesting analyses at CDF II. For more efficient muon registration in Run II it was decided to increase geometrical coverage. The so-called 'miniskirt' counters are part of this upgrade. The original design parameters of the 'miniskirt' and mixed 'miniskirt' scintillation counters for the CDF Muon System are presented. The modifications, testing and installation of these counters within the CDF Upgrade Project are described in detail. The timing characteristics of mixed 'miniskirt' counters are also investigated using cosmic muons. The measurements show that the time resolution does not exceed 2.2 ns

  11. Counter-diabatic driving for Dirac dynamics

    Science.gov (United States)

    Fan, Qi-Zhen; Cheng, Xiao-Hang; Chen, Xi

    2018-03-01

    In this paper, we investigate the fast quantum control of Dirac equation dynamics by counter-diabatic driving, sharing the concept of shortcut to adiabaticity. We systematically calculate the counter-diabatic terms in different Dirac systems, like graphene and trapped ions. Specially, the fast and robust population inversion processes are achieved in Dirac system, taking into account the quantum simulation with trapped ions. In addition, the population transfer between two bands can be suppressed by counter-diabatic driving in graphene system, which might have potential applications in opt-electric devices.

  12. Counter traction makes endoscopic submucosal dissection easier.

    Science.gov (United States)

    Oyama, Tsuneo

    2012-11-01

    Poor counter traction and poor field of vision make endoscopic submucosal dissection (ESD) difficult. Good counter traction allows dissections to be performed more quickly and safely. Position change, which utilizes gravity, is the simplest method to create a clear field of vision. It is useful especially for esophageal and colon ESD. The second easiest method is clip with line method. Counter traction made by clip with line accomplishes the creation of a clear field of vision and suitable counter traction thereby making ESD more efficient and safe. The author published this method in 2002. The name ESD was not established in those days; the name cutting endoscopic mucosal resection (EMR) or EMR with hook knife was used. The other traction methods such as external grasping forceps, internal traction, double channel scope, and double scopes method are introduced in this paper. A good strategy for creating counter traction makes ESD easier.

  13. An efficient anticoincidence counter

    CERN Multimedia

    1977-01-01

    This scintillation counter (about 25 cm diameter) was prepared at CERN for an experiment at the Saclay 600 MeV electron linac studying molecular processes originated in liquid hydrogen by muons. The counter is meant to surround the target and detect charged particles emerging from the hydrogen. The experiment was a CERN-Saclay collaboration which used the linac so as to take advantage of the time structure of the electron beam(see CERN Courier Sep 1977 and J. Bardin et al. Phys. Lett. B104 (1981) 320)

  14. COUNTER-PUNISHMENT, COMMUNICATION AND COOPERATION AMONG PARTNERS

    Directory of Open Access Journals (Sweden)

    Giulia eAndrighetto

    2016-04-01

    Full Text Available We study how communication affects cooperation in an experimental public goods environment with punishment and counter-punishment opportunities. Participants interacted over thirty rounds in fixed groups with fixed identifiers that allowed them to trace other group members’ behavior over time. The two dimensions of communication we study are asking for a specific contribution level and having to express oneself when choosing to counter-punish. We conduct four experimental treatments, all involving a contribution stage, a punishment stage and a counter-punishment stage in each round. In the first treatment communication is not possible at any of the stages. The second treatment allows participants to ask for a contribution level at the punishment stage and in the third treatment participants are required to send a message if they decide to counter-punishment. The fourth combines the two communication channels of the second and third treatments. We find that the three treatments involving communication at any of the two relevant stages lead to significantly higher contributions than the baseline treatment. We find no difference between the three treatments with communication. We also relate our results to previous results from treatments without counter-punishment opportunities and do not find that the presence of counter-punishment leads to lower cooperation level. The overall pattern of results shows that given fixed identifiers the key factor is the presence of communication. Whenever communication is possible contributions and earnings are higher than when it is not, regardless of counter-punishment opportunities.

  15. Improvement of a gas scintillation proportional counter

    International Nuclear Information System (INIS)

    Luo Zhiping; Liu Liye; Ma Jizeng; Chen Baowei; Iimoto, Takeshi; Kosako, Toshiso

    2008-01-01

    A prototype GSPC without the gas purification system was developed in China Institute for Radiation Protection (CIRP). Xenon filled GSPC has many advantages, including high energy resolution, large detection area, ability for implementing position sensitive detection, etc. It may find a wide application in low energy X-ray and γ-ray fields, e.g., astronomy X-ray detection, medical imaging. Further applications in neutron and charged heavy particle detection are also possible. Several tests for 241 Am and 55 Fe have been carried out to check out its preliminary performance. Currently the energy resolution is still far from expectation, nevertheless, the concept is proved to be promising and the experimental results suggest the way for further improvements. The possible ways for improvement of the detector performance are discussed in conclusion. This work was funded by National Natural Science Foundation of China. (author)

  16. Consumer Preferences for High Welfare Meat in Germany: Self-service Counter or Service Counter?

    Directory of Open Access Journals (Sweden)

    Ramona Weinrich

    2015-01-01

    Full Text Available Many people view animal welfare standards in the agricultural industry as critical and some consumers would prefer to buy high welfare meat. In order to successfully introduce high welfare meat products onto the market, some important marketing decisions must be made. Due to limited shelf space in retail outlets, niche products like high welfare meat cannot be placed both at the self-service counter and at the service counter. In order to analyze where to place it best an online survey of 642 German consumers was conducted. By means of factor and cluster analyses, consumers’ animal welfare attitudes and their preference for a point of purchase were combined. The different target groups were joint using cross tabulation analysis. The results reveal that consumers in the target group show a more positive attitude to the service counter.

  17. Proportionality lost - proportionality regained?

    DEFF Research Database (Denmark)

    Werlauff, Erik

    2010-01-01

    In recent years, the European Court of Justice (the ECJ) seems to have accepted restrictions on the freedom of establishment and other basic freedoms, despite the fact that a more thorough proportionality test would have revealed that the restriction in question did not pass the 'rule of reason' ...

  18. 21 CFR 866.2170 - Automated colony counter.

    Science.gov (United States)

    2010-04-01

    ...) MEDICAL DEVICES IMMUNOLOGY AND MICROBIOLOGY DEVICES Microbiology Devices § 866.2170 Automated colony counter. (a) Identification. An automated colony counter is a mechanical device intended for medical...

  19. Development of photocathodes for gas counters

    International Nuclear Information System (INIS)

    Chalot, J.F.

    1982-03-01

    A lot of ways of physics needs the development of high sensibility imaging devices with large sensitive surface. The problems brought by the building of such devices may be solved by the use of gaz counters. But we must sensitize these counters to low energy photons ( [fr

  20. Geometric covers, graph orientations, counter games

    DEFF Research Database (Denmark)

    Berglin, Edvin

    -directed graph is dynamic (can be altered by some outside actor), some orientations may need to be reversed in order to maintain the low out-degree. We present a new algorithm that is simpler than earlier work, yet matches or outperforms the efficiency of these results with very few exceptions. Counter games...... example is Line Cover, also known as Point-Line Cover, where a set of points in a geometric space are to be covered by placing a restricted number of lines. We present new FPT algorithms for the sub-family Curve Cover (which includes Line Cover), as well as for Hyperplane Cover restricted to R 3 (i...... are a type of abstract game played over a set of counters holding values, and these values may be moved between counters according to some set of rules. Typically they are played between two players: the adversary who tries to concentrate the greatest value possible in a single counter, and the benevolent...

  1. 21 CFR 866.2180 - Manual colony counter.

    Science.gov (United States)

    2010-04-01

    ...) MEDICAL DEVICES IMMUNOLOGY AND MICROBIOLOGY DEVICES Microbiology Devices § 866.2180 Manual colony counter. (a) Identification. A manual colony counter is a device intended for medical purposes that consists...

  2. On generating counter-rotating streamwise vortices

    KAUST Repository

    Winoto, S H

    2015-09-23

    Counter-rotating streamwise vortices are known to enhance the heat transfer rate from a surface and also to improve the aerodynamic performance of an aerofoil. In this paper, some methods to generate such counter-rotating vortices using different methods or physical conditions will be briefly considered and discussed.

  3. On generating counter-rotating streamwise vortices

    KAUST Repository

    Winoto, S H; Mitsudharmadi, Hatsari; Budiman, A C; Hasheminejad, S M; Nadesan, T; Tandiono; Low, H T; Lee, T S

    2015-01-01

    Counter-rotating streamwise vortices are known to enhance the heat transfer rate from a surface and also to improve the aerodynamic performance of an aerofoil. In this paper, some methods to generate such counter-rotating vortices using different methods or physical conditions will be briefly considered and discussed.

  4. Counter Traction Makes Endoscopic Submucosal Dissection Easier

    OpenAIRE

    Oyama, Tsuneo

    2012-01-01

    Poor counter traction and poor field of vision make endoscopic submucosal dissection (ESD) difficult. Good counter traction allows dissections to be performed more quickly and safely. Position change, which utilizes gravity, is the simplest method to create a clear field of vision. It is useful especially for esophageal and colon ESD. The second easiest method is clip with line method. Counter traction made by clip with line accomplishes the creation of a clear field of vision and suitable co...

  5. Israel's Counter-Terrorism Strategy and its Effectiveness

    National Research Council Canada - National Science Library

    Smith, Jerry D

    2005-01-01

    This thesis analyzes Israeli counter-terrorism strategy and its effectiveness. Because of ongoing suicide attacks from Palestinian and other terrorist organizations, Israel will continue to have an aggressive counter-terrorism strategy...

  6. CORNELL: CLEO's counters

    International Nuclear Information System (INIS)

    Anon.

    1982-01-01

    Particle identification by measuring ionization is complicated by the fact that the energy lost to ionization in passing through matter has large fluctuations, first calculated by Landau. These large fluctuations imply that many measurements must be made in order to determine the most probable ionization value that is characteristic of the particle type. The JADE chamber at PETRA and the TPC chamber at PEP measure both the ionization and the momenta of tracks in the same device. In the CLEO experiment at Cornell's CESR ring, ionization is measured in dedicated energy loss counters contained in each of the eight octants surrounding the drift chamber and superconducting coil. The last of these were installed in the summer of 1981, replacing Cherenkov counters that were used while the energy loss counters were being developed and built

  7. Channel coincidence counter: version 1

    International Nuclear Information System (INIS)

    Krick, M.S.; Menlove, H.O.

    1980-06-01

    A thermal neutron coincidence counter has been designed for the assay of fast critical assembly fuel drawers and plutonium-bearing fuel rods. The principal feature of the detector is a 7-cm by 7-cm by 97-cm detector channel, which provides a uniform neutron detection efficiency of 16% along the central 40 cm of the channel. The electronics system is identical to that used for the High-Level Neutron Coincidence Counter

  8. Broad Energy Range Neutron Spectroscopy using a Liquid Scintillator and a Proportional Counter: Application to a Neutron Spectrum Similar to that from an Improvised Nuclear Device.

    Science.gov (United States)

    Xu, Yanping; Randers-Pehrson, Gerhard; Marino, Stephen A; Garty, Guy; Harken, Andrew; Brenner, David J

    2015-09-11

    A novel neutron irradiation facility at the Radiological Research Accelerator Facility (RARAF) has been developed to mimic the neutron radiation from an Improvised Nuclear Device (IND) at relevant distances (e.g. 1.5 km) from the epicenter. The neutron spectrum of this IND-like neutron irradiator was designed according to estimations of the Hiroshima neutron spectrum at 1.5 km. It is significantly different from a standard reactor fission spectrum, because the spectrum changes as the neutrons are transported through air, and it is dominated by neutron energies from 100 keV up to 9 MeV. To verify such wide energy range neutron spectrum, detailed here is the development of a combined spectroscopy system. Both a liquid scintillator detector and a gas proportional counter were used for the recoil spectra measurements, with the individual response functions estimated from a series of Monte Carlo simulations. These normalized individual response functions were formed into a single response matrix for the unfolding process. Several accelerator-based quasi-monoenergetic neutron source spectra were measured and unfolded to test this spectroscopy system. These reference neutrons were produced from two reactions: T(p,n) 3 He and D(d,n) 3 He, generating neutron energies in the range between 0.2 and 8 MeV. The unfolded quasi-monoenergetic neutron spectra indicated that the detection system can provide good neutron spectroscopy results in this energy range. A broad-energy neutron spectrum from the 9 Be(d,n) reaction using a 5 MeV deuteron beam, measured at 60 degrees to the incident beam was measured and unfolded with the evaluated response matrix. The unfolded broad neutron spectrum is comparable with published time-of-flight results. Finally, the pair of detectors were used to measure the neutron spectrum generated at the RARAF IND-like neutron facility and a comparison is made to the neutron spectrum of Hiroshima.

  9. Efficiency calibration of solid track spark auto counter

    International Nuclear Information System (INIS)

    Wang Mei; Wen Zhongwei; Lin Jufang; Liu Rong; Jiang Li; Lu Xinxin; Zhu Tonghua

    2008-01-01

    The factors influencing detection efficiency of solid track spark auto counter were analyzed, and the best etch condition and parameters of charge were also reconfirmed. With small plate fission ionization chamber, the efficiency of solid track spark auto counter at various experiment assemblies was re-calibrated. The efficiency of solid track spark auto counter at various experimental conditions was obtained. (authors)

  10. Generalization of the development of liquid-sparkling counter

    International Nuclear Information System (INIS)

    Bian Zhengzhu; Zhang Jue; Zhang Jinwei

    2006-01-01

    This paper includes five parts. It not only reviews the development history of liquid-sparkling counter but refers that the appearance of coincident circuit is its milestone. The paper summarizes the resembled hard ware and soft ware and soft ware of liquid-sparkling counter of indoor and overseas, and prospects the development of liquid-sparkling counter in our country. (authors)

  11. Proportional reasoning

    DEFF Research Database (Denmark)

    Dole, Shelley; Hilton, Annette; Hilton, Geoff

    2015-01-01

    Proportional reasoning is widely acknowledged as a key to success in school mathematics, yet students’ continual difficulties with proportion-related tasks are well documented. This paper draws on a large research study that aimed to support 4th to 9th grade teachers to design and implement tasks...

  12. Advertising health: the case for counter-ads.

    Science.gov (United States)

    Dorfman, L; Wallack, L

    1993-01-01

    Public service advertisements have been used by many in hopes of "selling" good health behaviors. But selling good behavior--even if it could be done more effectively--is not the best goal for using mass media to prevent health problems. Personal behavior is only part of what determines health status. Social conditions and the physical environment are important determinants of health that are usually ignored by health promotion advertising. Public service advertising may be doing more harm than good if it is diverting attention from more effective socially based health promotion strategies. Counter-ads are one communications strategy that could be used to promote a broader responsibility for rectifying health problems. In the tradition of advocacy advertising directly promoting policy rather than products, counter-ads promote views consistent with a public health perspective. Counter-ads set the agenda for health issues, conferring status on policy-oriented strategies for addressing health problems. The primary purpose of counter-ads is to challenge the dominant view that public health problems reflect personal health habits. They are controversial because they place health issues in a social and political context. Advertising strategies for health promotion range over a spectrum from individually oriented public service advertising to socially oriented counter-advertising. The recent anti-tobacco campaign from the California Department of Health Services represents advertisements across the spectrum. Counter-ads that focus on a politically controversial definition for health problems are an appropriate and necessary alternative to public service advertising. PMID:8265756

  13. Use of miniature C-14 counters in dating and authentication in the museum

    International Nuclear Information System (INIS)

    Harbottle, G.; Sayre, E.V.; Stoenner, R.W.

    1983-01-01

    Curators often do not understand the basis for the C-14 method of age determination and its limitations. Purpose of this paper is to describe the underlying principles, and how these must influence the interpretation of the radiocarbon measurement of a museum specimen in terms of age. Several techniques for that measurement are described briefly, focussing on the miniature proportional counters that were developed for the Smithsonian Institution, and three museum problems are described which were attacked, and some interesting further research on museum objects that has been proposed. Finally some projections on the future applications of the different methods are made, in the context of museum work

  14. Counter - Drug: Mandate for the Army.

    Science.gov (United States)

    1991-03-01

    this comprehensive review will provide a basis for responding to new missions assigned...observations for determining the short-, mid-, and long-term direction of Army support to the national counter-drug effort. Also, this comprehensive review will provide...and long-term direction of Army support to the national counter-drug effort. Also, this comprehensive review will provide a basis for responding

  15. Hardware support for software controlled fast multiplexing of performance counters

    Science.gov (United States)

    Salapura, Valentina; Wisniewski, Robert W.

    2013-01-01

    Performance counters may be operable to collect one or more counts of one or more selected activities, and registers may be operable to store a set of performance counter configurations. A state machine may be operable to automatically select a register from the registers for reconfiguring the one or more performance counters in response to receiving a first signal. The state machine may be further operable to reconfigure the one or more performance counters based on a configuration specified in the selected register. The state machine yet further may be operable to copy data in selected one or more of the performance counters to a memory location, or to copy data from the memory location to the counters, in response to receiving a second signal. The state machine may be operable to store or restore the counter values and state machine configuration in response to a context switch event.

  16. Tests of BF3 counters with getter

    International Nuclear Information System (INIS)

    Comte, R.; Dauphin, G.

    1968-01-01

    BF 3 counters with addition of a getter have been developed to improve operation characteristics of these detectors in presence of strong gamma flows. The getter is made of an active coal deposit on the cathode. As noticed by other studies, the degradation of these counters is related to the exposure to strong neutron flows and to gamma radiations. The authors report tests performed on these counters with a brief presentation of the counters, and a presentation of the test installation. A threshold curve and an amplitude spectrum are obtained, and counting is performed for a fixed threshold before and after the exposure of detectors to variable doses of γ radiation. The results after a first 2 hour long irradiation, a 230 hour long second irradiation, and a third irradiation under high voltage (2100 V) are discussed. Thermal tests are then performed and commented

  17. COUNTER-ROTATION IN RELATIVISTIC MAGNETOHYDRODYNAMIC JETS

    Energy Technology Data Exchange (ETDEWEB)

    Cayatte, V.; Sauty, C. [Laboratoire Univers et Théories, Observatoire de Paris, UMR 8102 du CNRS, Université Paris Diderot, F-92190 Meudon (France); Vlahakis, N.; Tsinganos, K. [Department of Astrophysics, Astronomy and Mechanics, Faculty of Physics, University of Athens, 15784 Zografos, Athens (Greece); Matsakos, T. [Department of Astronomy and Astrophysics, The University of Chicago, Chicago, IL 60637 (United States); Lima, J. J. G., E-mail: veronique.cayatte@obspm.fr [Centro de Astrofísica, Universidade do Porto, Rua das Estrelas, 4150-762 Porto (Portugal)

    2014-06-10

    Young stellar object observations suggest that some jets rotate in the opposite direction with respect to their disk. In a recent study, Sauty et al. showed that this does not contradict the magnetocentrifugal mechanism that is believed to launch such outflows. Motion signatures that are transverse to the jet axis, in two opposite directions, have recently been measured in M87. One possible interpretation of this motion is that of counter-rotating knots. Here, we extend our previous analytical derivation of counter-rotation to relativistic jets, demonstrating that counter-rotation can indeed take place under rather general conditions. We show that both the magnetic field and a non-negligible enthalpy are necessary at the origin of counter-rotating outflows, and that the effect is associated with a transfer of energy flux from the matter to the electromagnetic field. This can be realized in three cases: if a decreasing enthalpy causes an increase of the Poynting flux, if the flow decelerates, or if strong gradients of the magnetic field are present. An illustration of the involved mechanism is given by an example of a relativistic magnetohydrodynamic jet simulation.

  18. Charged particle identification: Cherenkov counters at ISABELLE

    International Nuclear Information System (INIS)

    Etkin, A.; Kostoulas, I.; Leith, D.W.G.S.; Thun, R.

    1977-01-01

    A brief summary is given of a study of Cherenkov counters for ISABELLE. The study was certainy not exhaustive and was meant primarily to suggest future detector development. A substantial research effort is needed in order to insure that Cherenkov counters utilizing photoionization are fully exploited

  19. The great advance in the technology of particle detectors during the year was the discovery of the properties of multiwire proportional chambers and drift chambers

    CERN Multimedia

    CERN PhotoLab

    1968-01-01

    In these chambers each wire is an independent proportional counter with its own amplifier and logic circuit. The low cost of the associated electronics makes realistic moderately large systems, with thousands of wires. The resolution time of each wire is of the order of 100 ns, with 3mm spacing. Roger Bouclier is working on an early model tested in a PS beam-line.

  20. The Banking Counter-Guarantee. Juridical Regime

    Directory of Open Access Journals (Sweden)

    Postolache Rada

    2009-06-01

    Full Text Available Not so much studied by the specialised literature, the banking counter-guarantee may beconfounded with the other types of guarantee which frequently go with the guaranteed obligation –simple guarantee, collateral guarantee, the confirmation of the guarantee. The counter-guarantee may bean independent or accessory obligation, as the case may be, exclusively governed by its text, accordingto the parties’ will. At the same time, it is a complex juridical act, a contract whose contents cannot beset apart from the contracts connected form an “economic” point of view. The counter-guarantee is theresult of the banking practice and is generated by the need to make amends for the flaws generated bythe direct guarantee. The present research is focused on the analysis of the banking practice, normativeacts, jurisprudence and banking juridical literature.

  1. The scintillation counter system at the SAPHIR detector

    International Nuclear Information System (INIS)

    Bour, D.

    1989-10-01

    The scintillation-counters system of the SAPHIR-detector at the stretcher accelerator ELSA in Bonn consists of 64 counters. It supplies a fast hadronic trigger and is utilizised for the particle identification by time of flight measurements. Prototypes of the counters (340x21.25 x 6.0 cm 3 ) had been tested. The contribution to the resolution of the time of flight measurement was measured to σ=125 ps, the effective light velocity to 17.5 ns/cm and the attenuation length of 7.8 m. A pion kaon separation is possible up to a momentum of 1 GeV/c with time of flight measurement. With the first photon-beam at SAPHIR the counters were tested, first triggers were obtained and evaluated. (orig.) [de

  2. Development of a low-cost whole body counter

    International Nuclear Information System (INIS)

    Smith, M.H.; Gross, G.P.

    1991-01-01

    This paper documents the construction and calibration of a whole-body counter for the Radiation Safety Office of the Mayo Clinic in Rochester, MN. Changes in the federal regulations may require improved documentation of internal dose for radiation workers. A relatively inexpensive and simple chair-type whole-body counter may suit the needs of many organizations for in vivo assessment of gamma emitting radionuclides. A simple calibration phantom and a spreadsheet computer program were developed in conjunction with the counter. The spreadsheet can be used to calculate an estimate of committed effective dose equivalent based on activity in a subject and data from ICRP Publication 30. Using a count time of 10 minutes, the counter's minimum detectable activity ranged from 370 Bq to 1,110 Bq for 60 Co and 57 Co respectively. Other institutions will be able to assemble whole-body counters at low cost, often from surplus components. The spreadsheet is easily adapted to the needs of any institution and uses current methodology to estimate internal dose

  3. Quality control and the multicrystal counter

    International Nuclear Information System (INIS)

    Hart, G.C.; Davis, K.M.

    1983-01-01

    The reliability of multicrystal counters for use in counting large numbers of radioimmunoassay samples is studied. In particular, the dependencies of the outputs from the array of detectors, and hence their degree of matching, on the count rate and volume of the samples being counted are investigated. Quality control procedures are described to assist in the assurance of consistent performance of the counter in the clinical situation. (U.K.)

  4. Design and performance of a one square meter proportional counter system for hard X-ray astronomy

    International Nuclear Information System (INIS)

    Bazzano, A.; Boccaccini, L.; La Padula, C.D.; Mastropietro, M.; Patriarca, R.; Polcaro, F.; Ubertini, P.

    1983-01-01

    A versatile balloon borne hard X-ray experiment with a very large area (approx.= 1.1 m 2 ) and high spectral resolution has been developed for the study of the hard X-ray sources in the energy range 20-180 keV. The telescope consists of four multiwire proportional chambers (MWPC) that have a geometrical sensitive area of 2700 cm 2 each. The detector system has a sensitivity of approx.= 10 -5 photons cm -2 s -1 keV -1 during a typical balloon observation. A background rate of approx.= 3 x 10 -4 counts cm -2 s -1 keV -1 was observed in the operative energy range at 2.4 gm/cm 2 ceiling altitude and geographic latitude of 38 0 N. The design details, fabrication and flight performance of the instrument are briefly discussed with reference to the effectiveness of background reduction and other test parameters. (orig.)

  5. HOW THE WAR WAS ‘ONE’: COUNTERING VIOLENT EXTREMISM AND THE SOCIAL DIMENSIONS OF COUNTER-TERRORISM IN CANADA.

    Directory of Open Access Journals (Sweden)

    Tami Amanda Jacoby

    2016-03-01

    Full Text Available The current global “war on terror” highlights a fundamental quandary for all liberal democracies seeking to counter the violent extremism of their own citizens while maintaining civic rights and freedoms. This challenge accompanies a transformation in international conflict from inter-state war and superpower rivalry, to homegrown terrorism, radicalization-to-violence, Internet propaganda, and targeting and recruitment of vulnerable persons. These new threats shift the battlefield, as traditionally defined, to the home front, as extremist violence is nurtured by and perpetrated within public spaces, such as schools, places of religious worship, civil society and the home. Today, violence emanates from within liberal democratic society and its extremist motivations bypass the very institutions that would otherwise support civic rights, freedoms and multiculturalism. As such, attempts to counter extremist violence must appeal to the political, social, cultural, religious and familial aspects of human behavior alongside a parallel shift in efforts to keep citizens safe within their own social spaces. In recent years, Canada has been introduced to home grown and lone individual terrorism with the cases of attack against armed forces personnel in Saint-Jean-sur-Richelieu and Ottawa in 2014. This article identifies the social dimensions of counter-terrorism in the Canadian context, a propitious case by which to evaluate different approaches to countering violent extremism. Canadian initiatives - simultaneously proliferating and in their infancy – raise a host of questions about counter-terrorism in liberal democratic countries. For example, why do individuals radicalize-to-violence in rights-based and multicultural societies? How and when can the liberal democratic state best temper the radicalization process in ways that are effective and procedurally just? What state-society balance works best to counter radicalized viewpoints? Who are the

  6. Influence of tube volume on measurement uncertainty of GM counters

    Directory of Open Access Journals (Sweden)

    Stanković Koviljka Đ.

    2010-01-01

    Full Text Available GM counters are often used in radiation detection since they generate a strong signal which can be easily detected. The working principal of a GM counter is based on the interaction of ionizing radiation with the atoms and molecules of the gas present in the counter's tube. Free electrons created as a result of this interaction become initial electrons, i. e. start an avalanche process which is detected as a pulse of current. This current pulse is independent of the energy imparted on the gas, that being the main difference between a GM counter and the majority of other radiation detectors. In literature, the dependence on the incidence of radiation energy, tube's orientation and characteristics of the reading system are quoted as the main sources of measurement uncertainty of GM counters. The aim of this paper is to determine the dependence of measurement uncertainty of a GM counter on the volume of its counter's tube. The dependence of the pulse current on the size of the counter's tube has, therefore, been considered here, both in radial and parallel geometry. The initiation and expansion of the current pulse have been examined by means of elementary processes of electrical discharge such as the Markov processes, while the changes in the counter's tube volume were put to test by the space - time enlargement law. The random variable known as the 'current pulse in the counter's tube' (i. e. electrical breakdown of the electrode configuration has also been taken into account and an appropriate theoretical distribution statistically determined. Thus obtained theoretical results were then compared to corresponding experimental results established in controlled laboratory conditions.

  7. Design of a novel quantum reversible ternary up-counter

    Science.gov (United States)

    Houshmand, Pouran; Haghparast, Majid

    2015-08-01

    Reversible logic has been recently considered as an interesting and important issue in designing combinational and sequential circuits. The combination of reversible logic and multi-valued logic can improve power dissipation, time and space utilization rate of designed circuits. Only few works have been reported about sequential reversible circuits and almost there are no paper exhibited about quantum ternary reversible counter. In this paper, first we designed 2-qutrit and 3-qutrit quantum reversible ternary up-counters using quantum ternary reversible T-flip-flop and quantum reversible ternary gates. Then we proposed generalized quantum reversible ternary n-qutrit up-counter. We also introduced a new approach for designing any type of n-qutrit ternary and reversible counter. According to the results, we can conclude that applying second approach quantum reversible ternary up-counter is better than the others.

  8. Proportional 4π detector with an electric field of axial symmetry

    International Nuclear Information System (INIS)

    Guevara, E.A.; Costello, E.D.

    1984-01-01

    A gas-flow proportionalcounter, with an electric field of axial symmetry, designed and constructed by the authors, whose characteristics allow to work at positive gaseous pressure, is described. Based on the results from the measurements performed, the new detector proved to be suitable for the absolute calibration of beta-emitting radioactive sources and that the accuracy of the determinations can be compared with that achieved at metrologic laboratories of recognized accuracy. The slight dependence of the detector's efficiency on the nuclide's beta energy within the limits studied and its good performance for the measurements of non-punctual sources, are emphasized. Moreover, the spectra obtained, the disintegration schemes and the type of beta transition for each calibrated nuclide are presented. Some detector's parameters of certain interest, the capacity of the chambers in air and the loss of current at the working voltage are included in an annex. (M.E.L.) [es

  9. Application of a proportional counter to some particular cases of {alpha} measurements; Applications d'un compteur proportionnel a quelques cas particuliers de mesures {alpha}

    Energy Technology Data Exchange (ETDEWEB)

    Ferret, J; Gasc, M T; Le Du, R [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1965-07-01

    I - A measurement method based on {alpha} {gamma} coincidences is used for activity measurements on {sup 241}Am in the presence of a strong {alpha} activity due to Pu. The sensitivity of the apparatus makes it possible to detect: less than 10{sup -7} {mu}C {sup 241}Am in the presence of a Pu activities several hundred times greater. II - The same equipment has been used for {alpha} measurements on {alpha}-emitting sources in the presence of very strong {beta} and {gamma} activities. In particular results are given for {alpha}-activity measurements on powder samples. It is even possible in these conditions, to detect or measure {sup 241}Am. III - The equipment makes possible also: - the absolute calibration of a pure {sup 241}Am source - {sup 237}Np measurements - simultaneous measurements of {alpha}, {beta} and {gamma} activities in solid samples in various forms. IV - The assembly includes a small-size proportional counter operating in conjunction with a {gamma} probe, together with auxiliary electronic equipment (stabilized high voltages, amplifiers, a coincidence unit, a sealer). (authors) [French] I - Une methode de mesures par coincidences {alpha} {gamma} est utilisee pour des mesures d'activite de {sup 241}Am en presence d'activite {alpha} (due au Pu) importante. -La sensibilite de l'appareillage permet de deceler: moins de 10{sup -7} {mu}C {sup 241}Am dans les activites {alpha} Pu plusieurs centaines de fois plus importantes. II - Le meme appareillage a ete utilise pour des mesures {alpha} sur des sources emettrices {alpha} en presence d'activites {beta} et {gamma} tres importantes. En particulier des mesures d'activite {alpha} sur des echantillons de poudre sont exposees. Il est meme possible, dans ces conditions, de deceler ou mesurer {sup 241}Am. III - L'ensemble permet egalement: - l'etalonnage absolu d'une source de {sup 241}Am pur - des mesures de {sup 237}Np - des mesures simultanees d'activites {alpha}, {beta} et {gamma} dans des echantillons solides

  10. Neutron dose equivalent next to the target shield of a neutron therapy facility using an LET counter

    International Nuclear Information System (INIS)

    Stinchcomb, T.G.; Kuchnir, F.T.

    1981-01-01

    The use of a spherical tissue-equivalent proportional counter for measurements of the lineal energy (y) and derivations of the linear energy transfer (LET) for fast neutrons has the advantage of giving distributions of dose and dose equivalent as functions of either LET or y. A measurement next to the target shielding of the neutron therapy facility at the University of Chicago Hospitals and Clinics (UCHC) is described, and the data processing is outlined. The distributions are presented and compared to those from measurements in the neutron beam. The average quality factors are presented

  11. Design and performance of a one square meter proportional counter system for hard X-ray astronomy

    Energy Technology Data Exchange (ETDEWEB)

    Bazzano, A.; Boccaccini, L.; La Padula, C.D.; Mastropietro, M.; Patriarca, R.; Polcaro, F.; Ubertini, P. (Consiglio Nazionale delle Ricerche, Frascati (Italy). Lab. di Astrofisica Spaziale); Manchanda, R.K. (Consiglio Nazionale delle Ricerche, Frascati (Italy). Lab. di Astrofisica Spaziale; Tata Inst. of Fundamental Research, Bombay (India))

    1983-09-01

    A versatile balloon borne hard X-ray experiment with a very large area (approx.= 1.1 m/sup 2/) and high spectral resolution has been developed for the study of the hard X-ray sources in the energy range 20-180 keV. The telescope consists of four multiwire proportional chambers (MWPC) that have a geometrical sensitive area of 2700 cm/sup 2/ each. The detector system has a sensitivity of approx.= 10/sup -5/ photons cm/sup -2/ s/sup -1/ keV/sup -1/ during a typical balloon observation. A background rate of approx.= 3 x 10/sup -4/ counts cm/sup -2/ s/sup -1/ keV/sup -1/ was observed in the operative energy range at 2.4 gm/cm/sup 2/ ceiling altitude and geographic latitude of 38/sup 0/N. The design details, fabrication and flight performance of the instrument are briefly discussed with reference to the effectiveness of background reduction and other test parameters.

  12. Case study for co and counter swirling domestic burners

    Directory of Open Access Journals (Sweden)

    Ashraf Kotb

    2018-03-01

    Full Text Available In this case study, the influence of equivalence ratio for co and counter-swirl domestic burners compared with non-swirl design on the thermal efficiency as well as CO emissions has been studied using liquefied petroleum gas (LPG. Also, the flame stability, and pot height, which is defined as the burner-to-pot distance (H, of the co and counter domestic burners were compared. The analysis of the results showed that, for both swirl burners co and counter one the thermal efficiency under all operation conditions tested is higher than the non-swirled burner (base burner. For example, the thermal efficiency increased by 8.8%, and 5.8% than base burner for co and counter swirl, respectively at Reynolds number equal 2000 and equivalence ratio 1. The co and counter swirl burners show lower CO emission than the base burner. The co swirl burner has wider operation range than counter swirl. With the increase of pot height, the thermal efficiency of all burners decreases because the flame and combustion gases are cooled due to mixing with ambient air. As a result, the heat transfer is decreased due to atmospheric loss, which decrease the thermal efficiency.

  13. Portable counter for geological research

    Energy Technology Data Exchange (ETDEWEB)

    Russell, O J

    1949-05-01

    A portable counter which has been developed for prospecting for radio-active uranium and thorium minerals, for general geological investigations, and as an ultra-sensitive detector of lost or mislaid radium, is described. The aforementioned general usage includes the identification of changes in strata by means of the investigation of the slight amount of residual activity pressent in most minerals. The apparatus, which consists essentially of a scaled-down version of a standard laboratory Geiger-Muller counter, is highly sensitive since a variation equivalent to 4% of the cosmic ray background can be detected by a three-minute count.

  14. ''Conventional'' Cerenkov counters at ISABELLE

    International Nuclear Information System (INIS)

    Foley, K.J.

    1977-01-01

    Cherenkov counters to be used with ISABELLE are described. The three counters used in the Hadron Spectrometer can be used to identify particles in the range 10 to 40 GeV/c with pions separated from heavier particles down to approximately 3 GeV/c. A longer spectrometer for 400 x 400 GeV operation should also be used. The spectrometers may be used with CO 2 and H 2 . The range of particle identification of 8 to 60 GeV/c with pions separated from heavier particles down to approximately 5 GeV/c is possible

  15. Cosmic Ray Background Analysis For A Cargo Container Counter

    International Nuclear Information System (INIS)

    Ensslin, Norbert; Geist, W.H.; Lestone, J.P.; Mayo, D.R.; Menlove, Howard O.

    2001-01-01

    We have developed a new model for calculating the expected yield of cosmic-ray spallation neutrons in a Cargo Container Counter, and we have benchmarked the model against measurements made with several existing large neutron counters. We also developed two versions of a new measurement uncertainty prediction code based on Microsoft Excel spreadsheets. The codes calculate the minimum detectability limit for the Cargo Container Counter for either neutron singles or doubles counting, and also propagate the uncertainties associated with efficiency normalization flux monitors and cosmic ray flux monitors. This paper will describe the physics basis for this analysis, and the results obtained for several different counter designs.

  16. Micropipette as Coulter counter for submicron particles

    Science.gov (United States)

    Rudzevich, Yauheni; Ordonez, Tony; Evans, Grant; Chow, Lee

    2011-03-01

    Coulter counter based on micropipette has been around for several decades. Typical commercial Coulter counter has a pore size of 20 μ m, and is designed to detect micron-size blood cells. In recent years, there are a lot of interests in using nanometer pore size Coulter counter to detect single molecule and to sequence DNA. Here we describe a simple nanoparticle counter based on pulled micropipettes with a diameter of 50 -- 500 nm. Borosilicate micropipettes with an initial outer diameter of 1.00 mm and inner diameter of 0.5 mm are used. After pulling, the micropipettes are fire polished and ultrasound cleaned. Chlorinated Ag/AgCl electrodes and 0.1 M of KCl solution are used. The ionic currents are measured using an Axopatch 200B amplifier in the voltage-clamp mode. Several types and sizes of nanoparticles are measured, including plain silica and polystyrene nanospheres. The results will be discussed in terms of pH values of the solution and concentrations of the nanoparticles. Financial support from National Science Foundation (NSF-0901361) is acknowledged.

  17. Radiological Emergency Preparedness using Old ORTEC Whole Body Counter

    International Nuclear Information System (INIS)

    Badawy, W.M.

    2012-01-01

    During a radiological emergency (RE) a large number of occupational and public may be exposed externally and to a number of radionuclides internally as a result of inhalation or injection. The radiological effect is directly proportional to the time of exposure and the activity of the contaminant materials. The main task of this paper is to show the emergency preparedness capability of using the old ORTEC whole body counter (WBC). In case of a nuclear accident ORTEC WBC is ready for use to estimate the radioactivity which inhaled or digested with food, as well as in case of medical exposure in general and nuclear medicine in particular. The present study showed that the duration time to make analysis for only one individual is about 25 min. Hence 57 individuals are monitored per day. Consequently, old ORTEC WBC is effective tool in field of research and limited use for radiological and nuclear emergencies

  18. The Need for a United Nations Global Counter-Terrorism Coordinator

    Directory of Open Access Journals (Sweden)

    Howard Stoffer

    2013-08-01

    Full Text Available The case for a high level United Nations (UN Counter-Terrorism Coordinator position within the UN system has become increasingly urgent in 2013. This need has diluted some Member State reticence to creating a new Assistant Secretary-General position that would supervise and manage the existing counter-terrorism structures in the UN system. A Coordinator would have a basic responsibility to keep track of all of the activities of many formal inter-governmental organisations operating at the international, regional and sub-regional level and would also work closely with national counter-terrorism focal points. In this Policy Brief, Dr. Howard Stoffer reviews the debate among Security Council and Fifth Committee members about the efficacy of establishing a senior UN Global Counter-Terrorism Coordinator. He argues that the creation of such a position could lead to a restructuring of the UN counter-terrorism architecture as well as its funding within the UN budget and among donors. The position would eventually make the UN overall counter-terrorism effort, under the UN Global Counter-Terrorism Strategy, a stronger, more effective and more efficient process with measurable impact on the ground among Member States.

  19. Determination of 241Pu by low level β-proportional counting

    International Nuclear Information System (INIS)

    Rosner, G.; Hoetzl, H.; Winkler, R.

    1992-01-01

    A chemical separation procedure is described which allows the direct determination of low 241 Pu activities in environmental samples with a windowless gas-flow proportional counter. While current separation schemes based on anion exchange yield counting sources of sufficient purity for subsequent α-spectrometry, for β-counting of 241 Pu additional purification steps are required. A combination of anion exchange from 9 mol/1 HCl, LaF 3 precipitation and TTA extraction was found to be suitable even for analysis of long-range Chernobyl fallout samples which contained interfering radionuclides with β-activities at least 3 to 4 orders of magnitude higher than usually encountered. No difference is detectable between the results of the present, direct procedure and the results of the conventional indirect method based on the build-up of 241 Am. Average 241 Pu/ 239+241 Pu ratios in air and deposition samples taken at Neuherberg near Munich were 70±6 with the present procedure and 66±9 from 241 Am build-up. (author) 29 refs.; 3 tabs

  20. Lifetime characteristics of Gaiger-Muller counters

    Directory of Open Access Journals (Sweden)

    Kartalović Nenad M.

    2016-01-01

    Full Text Available This paper discusses the process of functional aging of Geiger-Muller counters. Two types of Geiger-Muller counter chambers were characterized in an experiment using a combined constant voltage. Chamber A had a coaxial geometry and chamber B had a plan-parallel geometry. The experimental results indicate that the aging process was faster in the case of chambers with a coaxial geometry. The results are explained based on the process of electrical discharges in gasses.

  1. Recoil-proton fast-neutron counter telescope

    Energy Technology Data Exchange (ETDEWEB)

    Pavan, P.; Toniolo, D.; Zago, G.; Zannoni, R. (Padua Univ. (Italy). Ist. di Fisica); Galeazzi, G.; Bressanini, G.

    1981-12-01

    A recoil-proton neutron counter telescope is described composed of a solid-state silicon transmission detector and a NE 102 A plastic scintillator, measuring the energy loss, the energy of the recoil protons and the time of flight between the two detectors. The counter exposed to monoenergetic neutron beams of energy from 6 to 20 MeV presents a low background and a moderate energy resolution. Its absolute efficiency is calculated up to 50 MeV.

  2. Recoil-proton fast-neutron-counter telescope

    Energy Technology Data Exchange (ETDEWEB)

    Galeazzi, G.; Pavan, P.; Toniolo, D.; Zago, G.; Zannoni, R.; Bressanini, G.

    1981-01-01

    A proton-recoil neutron counter telescope is described composed of a solid state silicon transmission detector and a NE 102 A plastic scintillator, measuring the energy loss, the energy of the recoil protons and the time-of-flight between the two detectors. The counter exposed to monoenergetic neutron beams of energy from 6 to 20 MeV, presents a low background and a moderate energy resolution. Its absolute efficiency is calculated up to 50 MeV.

  3. Presettable up-down CAMAC counter for 24 bit

    International Nuclear Information System (INIS)

    Kuhn, K.; Meyer, U.; Weidhase, F.

    1976-01-01

    A module containing a presettable binary up-down CAMAC counter for 24 bit is described. The use of dataway is discussed. As an example for application in nuclear physics, control of beam position by the up-down counter is illustrated

  4. Criticism and Counter-Criticism of Public Management: Strategy Models

    OpenAIRE

    Luis C. Ortigueira

    2007-01-01

    Critical control is very important in scientific management. This paper presents models of critical and counter-critical public-management strategies, focusing on the types of criticism and counter-criticism manifested in parliamentary political debates. The paper includes: (i) a normative model showing how rational criticism can be carried out; (ii) a normative model for oral critical intervention; and (iii) a general motivational strategy model for criticisms and counter-criticisms. The pap...

  5. Optimization of simultaneous tritium–radiocarbon internal gas proportional counting

    Energy Technology Data Exchange (ETDEWEB)

    Bonicalzi, R.M. [Seattle Central College, 1701 Broadway, Seattle, WA 98122 (United States); Aalseth, C.E.; Day, A.R.; Hoppe, E.W. [Pacific Northwest National Laboratory, 902 Battelle Boulevard, Richland, WA 99352 (United States); Mace, E.K., E-mail: Emily.Mace@pnl.gov [Pacific Northwest National Laboratory, 902 Battelle Boulevard, Richland, WA 99352 (United States); Moran, J.J.; Overman, C.T.; Panisko, M.E.; Seifert, A. [Pacific Northwest National Laboratory, 902 Battelle Boulevard, Richland, WA 99352 (United States)

    2016-03-21

    Specific environmental applications can benefit from dual tritium and radiocarbon measurements in a single compound. Assuming typical environmental levels, it is often the low tritium activity relative to the higher radiocarbon activity that limits the dual measurement. In this paper, we explore the parameter space for a combined tritium and radiocarbon measurement using a natural methane sample mixed with an argon fill gas in low-background proportional counters of a specific design. We present an optimized methane percentage, detector fill pressure, and analysis energy windows to maximize measurement sensitivity while minimizing count time. The final optimized method uses a 9-atm fill of P35 (35% methane, 65% argon), and a tritium analysis window from 1.5 to 10.3 keV, which stops short of the tritium beta decay endpoint energy of 18.6 keV. This method optimizes tritium-counting efficiency while minimizing radiocarbon beta-decay interference. - Highlights: • Use of a single compound (methane) for dual tritium and radiocarbon measurements. • Optimized analysis window for simultaneous tritium and radiocarbon measurement. • Allows for optimization of tritium counting in the presence of radiocarbon.

  6. Expanded and combined uncertainty in measurements by GM counters

    International Nuclear Information System (INIS)

    Stankovic, K.; Arandjic, D.; Lazarevic, Dj.; Osmokrovic, P.

    2007-01-01

    This paper deals with possible ways of obtaining expanded and combined uncertainty in measurements for four types of GM counters with a same counter's tube, in cases when the contributors of these uncertainties are cosmic background radiation and induced overvoltage phenomena. Nowadays, as a consequence of electromagnetic radiation, the latter phenomenon is especially marked in urban environments. Based on experimental results obtained, it has been established that the uncertainties of an influenced random variable 'number of pulses from background radiation' and 'number of pulses induced by overvoltage' depend on the technological solution of the counter's reading system and contribute in different ways to the expanded and combined uncertainty in measurements of the applied types of GM counters. (author)

  7. Lessons from History for Counter- Terrorism Strategic Communications

    NARCIS (Netherlands)

    Ingram, H.J.; Reed, A.G.

    2016-01-01

    Drawing on the Counter-terrorism Strategic Communication (CTSC) Project’s research paper “A Brief History of Propaganda during Conflict“, this Policy Brief lays out the key policy-relevant lessons for developing effective counter-terrorism strategic communications. It presents a framework of

  8. Operation and application of tissue-equivalent proportional counters

    International Nuclear Information System (INIS)

    Gerdung, S.; Roos, H.

    1995-01-01

    The application of TEPCs during the past decades in dosimetry, radiation protection and radiation therapy has revealed their large potential but also the necessity of careful operation. This paper reviews the experience gathered in the past and summarises the experimental procedures to ensure proper TEPC operation. The measurement system is described including detector, electronics and quality assurance. The pulse height analysis and its interpretation in terms of microdosimetric spectra and mean values are presented as well as the variance method. On the basis of these evaluation procedures, the second part of the paper presents some typical examples of TEPC applications: dose spectrometry, time-of-flight techniques and the measurement of dose equivalent quantities. Special attention is paid to possible extensions but also to limitations of the use of TEPCs in the various fields of application. (Author)

  9. Method for discriminating microphonic noise in proportional counters

    International Nuclear Information System (INIS)

    Gold, R.

    1991-01-01

    This patent describes a detector system responsive to nuclear events for installation in a downhole logging tool including measuring well drilling equipment which subjects the detection system to microphonic shock. It comprises a closed chamber subject to impinging nuclear events and having two separate anode wires therein spaced apart from each other and spanning the chamber, providing a pair of separated spaced output terminals to thereby form an output signal; circuit means connecting from at least one of the chamber output terminals to a different amplifier means having two input terminals; the circuit means connected from the output terminal of the chamber to one of the input terminals of the differential amplifier means to cause formation of an output signal from the differential amplifier means; and vibration shock responsive means mounted in the detector system and having an output terminal which forms an output signal for connection to a second input at the differential circuit means so that microphonic signals from the chamber and the shock responsive means are provided thereto and tend to cancel when applied to the input terminals thereof, and wherein the shock responsive means does not cancel at the differential circuit means signals relating to nuclear events from the detector system

  10. Counter of radiation in body parts

    International Nuclear Information System (INIS)

    Pollard, D.E.

    1983-01-01

    A new radiation counter for the determination of radiocontaminated body parts has been designed. Composed of several movable detectors, shielded from background radiation and focused on different parts of the human body by narrow apertures in the lead enclosure, the invention provides a quick tool for quantitative and qualitative part-by-part analysis of the body with respect to radiocontamination. The counter can be handled easily by the tested person himself and consequently, it is suitable for mass controls etc. (G.J.P.)

  11. Construction and calibration studies of the SAPHIR scintillation counters

    International Nuclear Information System (INIS)

    Kostrewa, D.

    1988-03-01

    For the scintillation counter system of the SAPHIR detector at the stretcher ring ELSA in Bonn 50 time of flight counters and 12 trigger counters have been built. Each of them has two photomultipliers, one at each side. A laser calibration system with a pulsed nitrogen laser as central light source to monitor these photomultipliers has been optimized. It was used to adjust the photomultipliers and to test their long and short time instabilities. (orig.)

  12. Study of semileptonic and leptonic neutral-current processes and of $\\mu$-polarization using counter techniques

    CERN Document Server

    2002-01-01

    .PP This experiment will study semileptonic neutral current neutrino interactions with nucleons, using principally the dichromatic neutrino beam N1 and will make measurements of the polarization of muons produced in the WA1 experiment by neutrino-nucleon interactions, using the horn-focused broad-band neutrino The main part of the apparatus is a fine-grained target calorimeter in which the energy and direction of the hadronic jet resulting from the neutrino scattering is measured by electronic techniques. It is supplemented by a muon detector and spectrometer. The fine-grained calorimeter is used as a polarimeter for muons produced in WA1. \\\\ \\\\ The calorimeter is composed of 13 modules, each 1.2 m long and 4~m x 4~m in cross section. A module consists of six 3 m x 3 m target plates made of 8 cm thick marble with 12 cm gaps for insertion of 20 scintillation counters of 15 cm width and 3 cm thickness, 128 proportional counters of 3~x~3~cm|2 cross-section and 4~m length, and 256 streamer tubes of 0.9~x~0.9~cm|2...

  13. An extended range neutron rem counter

    International Nuclear Information System (INIS)

    Birattari, C.; Nuccetelli, C.; Pelliccioni, M.; Silari, M.

    1990-01-01

    Extensive Monte Carlo calculations have been carried out to assess the possibility of extending the sensitivity of a neutron rem counter of the Andersson-Braun type up to several hundred MeV. The validity of the model adopted has first been checked by comparing with experimental data the calculated response curve and the angular dependence of the sensitivity for a well known commercial rem counter. Next, a number of modifications to the configuration of the moderator-attenuator have been investigated. The response functions and angular distributions produced by two simple solutions yielding an instrument with a sensitivity extended up to 400 MeV are presented. The response of the original rem counter and of its two modified versions to nine test spectra has also been calculated. The resulting instrument is transportable rather than portable, but the availability of an extended range neutron survey meter would be of great advantage at medium and high energy particle accelerator facilities. (orig.)

  14. Townsend coefficients of gases in avalanche counters

    International Nuclear Information System (INIS)

    Brunner, G.

    1978-01-01

    Though much work has been done by many authors in the last few years in the development and application of avalanche counters for ion radiation, it is based upon values of the Townsend coefficients as the essential gas parameter, which were determined many years ago for much lower reduced field strengths F/p than prevail in such counters. Therefore absolute determinations of α in vapours of methyl alcohol, cyclohexane, acetone, and n-heptene were performed under original conditions of avalanche counters. The values obtained do not differ by more than 30%-50% from the former values indeed, extrapolated over F/p for the first three mentioned substances, but the amounts of A and B in the usual representation α/p=A exp(-B(F/p)) are much greater for the stronger reduced fields. This is of importance for such counter properties as the dependence of pulse heights on pressure, voltage, electrode distance etc., which are governed by other combinations of A and B than α/p itself. A comparison of results for different ionic radiations shows a marked influence of the primary ionization density along the particle tracks which is hard to explain. (Auth.)

  15. A gridded air counter for measuring exoelectrons

    International Nuclear Information System (INIS)

    Nagase, Makoto; Chiba, Yoshiya; Kirihata, Humiaki.

    1980-01-01

    A gridded air counter with a quenching circuit is described, which serves to detect low-energy electrons such as thermionic electrons, photoelectrons and exoelectrons emitted into the atmospheric air. The air counter consists of a loop-shaped anode and two grids provided for quenching the gas discharge and for protecting the electron emitter from the positive ion bombardment. The quenching circuit with a high input sensitivity of 5 mV detects the initiation gas discharge caused by an incident electron and immediately supplies a rectangular wave pulse of 300 V in amplitude and of more than 3 msec in width to the quenching grid near the anode. Simultaneously, the voltage of the suppressor grid is brought down and kept at -30 V against the earthed sample for the same period of time. Performance of the gridded air counter was examined by use of photoelectrons emitted from an abraded aluminum plate. The quenching action was successfully accomplished in the anode voltage range from 3.65 to 3.95 kV. The photoelectrons emitted into the atmosphere could be counted stably by use of this counter. (author)

  16. Helium-air counter flow in rectangular channels

    International Nuclear Information System (INIS)

    Fumizawa, Motoo; Tanaka, Gaku; Zhao, Hong; Hishida, Makoto; Shiina, Yasuaki

    2004-01-01

    This paper deals with numerical analysis of helium-air counter flow in a rectangular channel with an aspect ratio of 10. The channel has a cross sectional area of 5-50 mm and a length of 200 mm. The inclination angle was varied from 0 to 90 degree. The velocity profiles and concentration profiles were analyzed with a computer program [FLUENT]. Following main features of the counter flow are discussed based on the calculated results. (1) Time required for establishing a quasi-steady state counter flow. (2) The relationship between the inclination angle and the flow patterns of the counter flow. (3) The developing process of velocity profiles and concentration profiles. (4) The relationship between the inclination angle of the channel and the velocity profiles of upward flow and the downward flow. (5) The relationship between the concentration profile and the inclination angle. (6) The relationship between the net in-flow rate and the inclination angle. We compared the computed velocity profile and the net in-flow rate with experimental data. A good agreement was obtained between the calculation results and the experimental results. (author)

  17. Reactance and Coping Responses to Tobacco Counter-Advertisements.

    Science.gov (United States)

    Wehbe, Michelle S; Basil, Michael; Basil, Debra

    2017-07-01

    Tobacco prevention messages generally take one of three tactics: They can be educational, attack the tobacco industry, or attack particular brands. Being a smoker and smoking a particular brand may form an essential part of a person's self-identity. As such, reactance theory suggests that attack messages can unintentionally attack smokers' self-image. A 2 × 2 × 2 × 2 experiment using six different messages and 260 respondents tested whether smokers have different reactions to tobacco counter-advertisements than nonsmokers. It also examined whether attacking a smoker's brand leads to greater reactance and other maladaptive responses compared to attacking other brands. Consistent with predictions, smokers reported more maladaptive coping responses and fewer adaptive coping responses to tobacco counter-ads than nonsmokers. The study also reveals differences attributable to brand identification. These findings suggest that interventions should consider different counter-advertising tactics for smokers and nonsmokers. Similar admonitions may apply to counter-advertising strategies on other health issues.

  18. Whole-body counter

    Energy Technology Data Exchange (ETDEWEB)

    Fedorov, G A; Kosterev, V V

    1975-01-24

    A counter for detecting radiation of a man (CRM) is described, which consists of two measuring converters and a recording device. In order to obtain data on spatial distribution of a gamma-radiating nuclide studied, a fixed collimator and a mobile coder made of separate slit elements are placed between the measuring converters and an object investigated.

  19. Electromagnetically Operated Counter

    Science.gov (United States)

    Goldberg, H D; Goldberg, M I

    1951-12-18

    An electromagnetically operated counter wherein signals to be counted are applied to cause stepwise rotation of a rotatable element which is connected to a suitable register. The mechanism involved consists of a rotatable armature having three spaced cores of magnetic material and a pair of diametrically opposed electromagnets with a suitable pulsing circuit to actuate the magnets.

  20. Hardware support for software controlled fast reconfiguration of performance counters

    Science.gov (United States)

    Salapura, Valentina; Wisniewski, Robert W.

    2013-06-18

    Hardware support for software controlled reconfiguration of performance counters may include a plurality of performance counters collecting one or more counts of one or more selected activities. A storage element stores data value representing a time interval, and a timer element reads the data value and detects expiration of the time interval based on the data value and generates a signal. A plurality of configuration registers stores a set of performance counter configurations. A state machine receives the signal and selects a configuration register from the plurality of configuration registers for reconfiguring the one or more performance counters.

  1. Quality assurance regime for the fabrication and calibration of ambient dose rate measuring instruments with proportional counters

    International Nuclear Information System (INIS)

    Schloesser, H.

    1997-01-01

    The proportional detectors FHZ 600A and FHZ 601A serve as examples to illustrate the quality assurance regime applied in fabrication and operation of the detector. Calibration is done by a licensed establishment connected to the standard 137 Cs calibration source at PTB. In addition to the basic calibration, the intrinsic selfdosing effect of the device and its response to cosmic radiation are known and can be taken into account in interpretations of measured results. The individual calibration of the intelligent probes of type FHZ 601A achieves a yet better measuring accuracy at higher dose rates, as compared to the basic calibration and performance of the FHZ 600A probes, as was shown by a type approval test. The paper also shows that control measurements and ''intelligent'' measuring systems with integrated checking routines improve the measuring reliability. (orig./CB) [de

  2. Output pulse height distribution of the GM counters

    International Nuclear Information System (INIS)

    Zhang Songshou; Xiong Jianping

    1995-01-01

    The GM counters are the radiation detectors most in use. It has special advantages compared with other detectors. This paper introduces the output pulse height distribution of the GM counters, gives the measuring instruments and methods. The measuring results, some discussions, and useful conclusion are given as well

  3. 'Miniskirt' counter array at CDF II

    International Nuclear Information System (INIS)

    Artikov, A.; Artikov, A.

    2006-01-01

    Full text: Muon detection is fundamental for the most of the interesting analyses at CDF. At the course of Run II, the collaboration expects to collect hundreds of t t-bar decays yielding a muon as well as several million B-hadron events involving J/ψ → μ + μ - decays. Muon detection is also of fundamental importance in the study of W-boson properties and in the search for Higgs production associated with W or Z bosons. Considerable effort therefore went into extending the muon detector coverage for Run II, which started in March 2001. The CDF II muon detector system consists of multiple layers of drift chambers and scintillation counters, which span the pseudorapidity (|η|) range between 0 and 1.5. Detectors spanning different ranges have different geometries, and the muon scintillation counter system includes subsystems in the regions that have come to be known as the 'central' (0 pe for WLS fiber readout is smaller than for conventional readout, we can also expect an increase in the statistical contribution to the overall uncertainty. Our first concern, before adopting this solution, was therefore to ascertain that the mean timing resolution obtained under these conditions was adequate. The modifications, testing and installation of these counters within the CDF Upgrade Project are described in detail. The timing characteristics of MSX' counters are also investigated using cosmic muons. The measurements show that the time resolution does not exceed 2.2 ns. (author)

  4. Responding to Cyber Jihad: Towards an Effective Counter Narrative

    Directory of Open Access Journals (Sweden)

    Bibi van Ginkel

    2015-03-01

    Full Text Available “Who is in control of the narrative?” is the mantra that now echoes in the hallways of the EU’s headquarters in Brussels. Spurred in part by large-scale jihadist propaganda, approximately 20,000 people from 50 countries have joined the fight in Iraq and Syria. So far, authorities in their countries of origin have not been able to address the jihadist radicalisation messages transmitted via the internet and social media. Many new initiatives were recently announced, however, including the establishment of a European counter-narrative centre in Brussels. Research Fellow Dr. Bibi van Ginkel analyses the role of the internet and social media in processes of radicalisation. It offers an outline of the various aspects of the jihadist narrative, in order better to understand what message needs to be countered. The counter-actions against this cyber jihad can take different forms. Parallel to the way in which advertisement campaigns are tailored to sell products to a certain target group, strategic communication should take into account how a number of recurring elements play a role in the counter-messaging. The understanding of who the target group is, what jihadist narrative is used and how that message can be countered, who the credible messenger should be, and what medium can best be used to deliver the message are all relevant questions that can only be answered in a context-specific manner. The Research Paper concludes with several recommendations on how the recently announced new European counter-narrative centre can effectively contribute to the already diverse landscape of counter-narrative initiatives.

  5. Countering the ‘Natural’ Organizational Self on Social Media

    DEFF Research Database (Denmark)

    Johansen, Trine Susanne

    2017-01-01

    , challenge and contradict organizational self-narration in light of market place skepticism and cynicism. The study identifies three strategies of counter-narrativizing (authenticity, legitimacy and irony) based on juxtaposing pairs of opposites. Moreover, it suggests counter-narration to be a natural......Using narrative as a theoretical and methodological lens, this study explores digital processes of organizational identity construction in the intersection between organization and market.The purpose is to understand the ways in which online interactions produce counter-narratives that contrast...

  6. Sources of Brazil's Counter-Hegemony

    Directory of Open Access Journals (Sweden)

    Marcos Aurelio Guedes de Oliveira

    2010-01-01

    Full Text Available There have been two key initiatives taken in the last two decades in Brazil to create a counter-hegemonic project for the country. One initiative resulted from Brazil's business community and high-level State bureaucracy and aimed at forming a regional economic and political bloc that would guarantee and enlarge a relative independence from the hegemonic powers. The other resulted from the emergence of the new unionist movement in São Paulo and from the formation of Partido dos Trabalhadores and aimed at promoting radical democratization and reducing social exclusion. Both initiatives have created policies and changes that have converged to enhance Brazil's counter-hegemonic position as a regional and emerging power.

  7. Description of the manufacture of a Geiger-Muller counter with window

    International Nuclear Information System (INIS)

    Granados, C. E.

    1959-01-01

    Total details about the manufacture elements in counter fabrication and the way of obtention are described as well as total indications useful in the installation process and filling of the counter. The appropriate materials and precautions that might be adopted in order to obtain counters with uniform operation and good characteristics, are described. Counters are of brass, with thin mica or aluminium windows and operate at 1100 V approximately with a slope lower than 5 % 1100 V. (Author)

  8. The Counter Terrorist Classroom: Religion, Education, and Security

    Science.gov (United States)

    Gearon, Liam

    2013-01-01

    The article identifies international cases--from the United States, Europe, and the United Nations--of an emergent interface of religion, education, and security. This is manifest in the uses of religion in education to counter religious extremism, the notional "counter terrorist classroom." To avoid an over-association of extremism with…

  9. Counter-Buffing: A Visual Criticism of Guerrilla Advertising

    Science.gov (United States)

    Lauzon, Robb Conrad; Cooke, Laquana

    2017-01-01

    This article addresses and explores hip-hop's reclamation of space using transit as a public bulletin. It is situated within counter-publics discourse and couched in the theoretical frameworks offered by visual rhetorical theory. This article also discusses hip-hop counter-publics through guerrilla advertising by former graffiti artists, SKI and…

  10. The IFIN-HH triple coincidence liquid scintillation counter

    CSIR Research Space (South Africa)

    Razdolescu, AC

    2006-10-01

    Full Text Available at IFIN-HH using a 3 H standard. The performances of the IFIN-HH TDCR counter was checked against the measurement results of the TDCR counters of CSIR NML (South Africa), RC (Poland) and LNHB (France). A set of ready-to-measure Ni-63 sources in liquid...

  11. Picosecond-precision multichannel autonomous time and frequency counter

    Science.gov (United States)

    Szplet, R.; Kwiatkowski, P.; RóŻyc, K.; Jachna, Z.; Sondej, T.

    2017-12-01

    This paper presents the design, implementation, and test results of a multichannel time interval and frequency counter developed as a desktop instrument. The counter contains four main functional modules for (1) performing precise measurements, (2) controlling and fast data processing, (3) low-noise power suppling, and (4) supplying a stable reference clock (optional rubidium standard). A fundamental for the counter, the time interval measurement is based on time stamping combined with a period counting and in-period two-stage time interpolation that allows us to achieve wide measurement range (above 1 h), high precision (even better than 4.5 ps), and high measurement speed (up to 91.2 × 106 timestamps/s). The frequency is measured up to 3.0 GHz with the use of the reciprocal method. Wide functionality of the counter includes also the evaluation of frequency stability of clocks and oscillators (Allan deviation) and phase variation (time interval error, maximum time interval error, time deviation). The 8-channel measurement module is based on a field programmable gate array device, while the control unit involves a microcontroller with a high performance ARM-Cortex core. An efficient and user-friendly control of the counter is provided either locally, through the built-in keypad or/and color touch panel, or remotely, with the aid of USB, Ethernet, RS232C, or RS485 interfaces.

  12. Dimensions of Counter-Narratives

    DEFF Research Database (Denmark)

    2019-01-01

    The book welcomes proposals for chapter contributions on a wide array of topics related to the narratological notion of counter-narratives. By way of example, the topic has hitherto been treated by disciplines and subjects such as literature studies, organization studies, corporate communication...

  13. Analysis of over-the-counter medicines use among nursing students

    Directory of Open Access Journals (Sweden)

    Mlinar Suzana

    2015-01-01

    Full Text Available Background/Aim. The use of over-the-counter (OTC medication is widespread among the adult and student populations in Slovenia. The aim of the study was to analyse the prevalence of OTC medicines use among nursing students with respect to sociodemographic characteristics. Methods. A total of 241 nursing students in the Faculty of Health Sciences, Ljubljana, were included in the cross-sectional study. A questionnaire was created for the purposes of the study. Statistical analysis was performed with SPSS 20. Descriptive statistics, t-test and the contingency coefficient were calculated. Statistical significance was set at the p-value of < 0.05. Results. The study showed that the use of prescription drugs was significantly higher in women (p = 0.029, students living in rural areas (p = 0.005 and students who described themselves as being of bad health (p = 0.008. At the same time, a third of the respondents had been taking one OTC medicine within the last month; those taking several prescription drugs commonly administered several over-the-counter medicines (p = 0.027. Women used OTC medicines to treat pain and fever (p = 0.001, respiratory issues (p = 0.015, and fungal infections (p < 0.000 more often than men. OTC medicines were also used to treat minor mental health issues by a higher proportion of respondents over 21 years of age (p = 0.005 and women (p < 0.000, while over-the-counter medicines for treating skin conditions were more frequently used in rural areas (p = 0.006. Conclusion. Nursing students tend to use OTC medicines on their own accord, receiving instructions for safe use with their purchase, which points to adequate promotion of safe use of medications in Slovenia. Men's assessment of their personal health tends to be better than that of women, who also use medication more frequently. A connection between poor health and a higher incidence of the use of OTC medicines was established. The use of OTC medicines to treat minor mental

  14. Technical Note: Characterization of a static thermal-gradient CCN counter

    Directory of Open Access Journals (Sweden)

    G. P. Frank

    2007-06-01

    Full Text Available The static (parallel-plate thermal-gradient diffusion chamber (SDC was one of the first instruments designed to measure cloud condensation nuclei (CCN concentrations as a function of supersaturation. It has probably also been the most widely used type of CCN counter. This paper describes the detailed experimental characterization of a SDC CCN counter, including calibration with respect to supersaturation and particle number concentration. In addition, we investigated the proposed effect of lowered supersaturation because of water vapor depletion with increasing particle concentration. The results obtained give a better understanding why and in which way it is necessary to calibrate the SDC CCN counter. The calibration method is described in detail and can, in parts, be used for calibrations also for other types of CCN counters.

    We conclude the following: 1 it is important to experimentally calibrate SDC CCN counters with respect to supersaturation, and not only base the supersaturation on the theoretical description of the instrument; 2 the number concentration calibration needs to be performed as a function of supersaturation, also for SDC CCN counter using the photographic technique; and 3 we observed no evidence that water vapor depletion lowered the supersaturation.

  15. Possibility of semiconductor counters application for internal contamination measurement of whole human body

    International Nuclear Information System (INIS)

    Cunic, O.; Orlic, M.; Bek-Uzarov, Dj.; Pavlovic, S.; Pavlovic, R.

    1997-01-01

    The possibility of high resolution semiconductor counters application in 'Vinca' Whole Body Counter for direct beta-gamma internal contamination measurement are discussed, assuming the following relevant characteristics: efficiency, resolution and counter price. A comparison with appropriate characteristics of NaI(Tl) crystal used in 'Vinca' WBC is treated. It is evident that the scintillation counters have the higher detection efficiency, but HPGe counters having much better resolution and recently lowest prices are also acceptable to join the existing NaI(Tl) counters with the HPGe counters in the same time, allow better spectral analyses of the human body activity and additionally more precise estimation of the equivalent doses rate which is generally a essential problem in WBC measurements. (author)

  16. The research on the failure regularity of GM counter tubes

    International Nuclear Information System (INIS)

    Li Jiyuan; Huai Guangli; Xie Bo; Zhang Hao

    2002-01-01

    The reliability of GM counter tubes should be described by useful time before failure-life and failure rate during life. A new method to study the failure regularity of GM counter tubes is advanced and adopted. The essential point of the method is that after the GM counter tubes of the instruments in use is tested, both the performance parameters and other information of the GM counter tubes and the instruments collected are recorded. Then database is created. Failure criterion is ascertained. The GM counter tubes are inspected to determine whether they are failure. Failure mode should be decided if the GM counter tubes failure. The GM counter tubes with the same useful year come together to make up a subsample. According to the relevant information, the number of the subsample is restored to the number of the sample that initially put into use. Then the number of failure sample is counted and at the same time the distribution of failure mode is got. The parameter m, γ, t 0 of Weibull distribution function are calculated with method of linear fit. Thus mean life, failure rate and other character values are obtained. Using this method, useful life and failure rate are determined. The conclusion is that the useful life is 18-20 years and the failure rate is 5 x 10 -6 and 4 x 10 -6 /h respectively during the course

  17. Microchip Coulter particle counter

    DEFF Research Database (Denmark)

    Larsen, Ulrik Darling; Blankenstein, Gert; Branebjerg, J.

    1997-01-01

    This paper presents a micro device employing the Coulter principle for counting and sizing of living cells and particles in liquid suspension. The microchip Coulter particle counter (μCPC) has been employed in a planar silicon structure covered with glass, which enables detailed observation during...

  18. Implementation strategies to promote community-engaged efforts to counter tobacco marketing at the point of sale.

    Science.gov (United States)

    Leeman, Jennifer; Myers, Allison; Grant, Jennifer C; Wangen, Mary; Queen, Tara L

    2017-09-01

    The US tobacco industry spends $8.2 billion annually on marketing at the point of sale (POS), a practice known to increase tobacco use. Evidence-based policy interventions (EBPIs) are available to reduce exposure to POS marketing, and nationwide, states are funding community-based tobacco control partnerships to promote local enactment of these EBPIs. Little is known, however, about what implementation strategies best support community partnerships' success enacting EBPI. Guided by Kingdon's theory of policy change, Counter Tools provides tools, training, and other implementation strategies to support community partnerships' performance of five core policy change processes: document local problem, formulate policy solutions, engage partners, raise awareness of problems and solutions, and persuade decision makers to enact new policy. We assessed Counter Tools' impact at 1 year on (1) partnership coordinators' self-efficacy, (2) partnerships' performance of core policy change processes, (3) community progress toward EBPI enactment, and (4) salient contextual factors. Counter Tools provided implementation strategies to 30 partnerships. Data on self-efficacy were collected using a pre-post survey. Structured interviews assessed performance of core policy change processes. Data also were collected on progress toward EBPI enactment and contextual factors. Analysis included descriptive and bivariate statistics and content analysis. Following 1-year exposure to implementation strategies, coordinators' self-efficacy increased significantly. Partnerships completed the greatest proportion of activities within the "engage partners" and "document local problem" core processes. Communities made only limited progress toward policy enactment. Findings can inform delivery of implementation strategies and tests of their effects on community-level efforts to enact EBPIs.

  19. Lessons from History for Counter-Terrorism Strategic Communications

    Directory of Open Access Journals (Sweden)

    Haroro J. Ingram

    2016-06-01

    Full Text Available Drawing on the Counter-terrorism Strategic Communication (CTSC Project’s research paper “A Brief History of Propaganda during Conflict“, this Policy Brief lays out the key policy-relevant lessons for developing effective counter-terrorism strategic communications. It presents a framework of interrelated macro-, mezzo- and micro-level considerations for maximizing the efficacy of not just a strategic communications campaign but message design. Historical examples are drawn upon to illustrate their practical application. The Policy Brief concludes by analysing four key strategic-policy principles arguing that a counter-terrorism strategic communications campaign is more likely to be successful if it is based on the cumulative effects of a multidimensional messaging strategy.

  20. 4-GHz counters bring synthesizers up to speed

    Science.gov (United States)

    Lee, F.; Miller, R.

    1984-06-01

    The availability of digital IC counters built on GaAs makes direct frequency division in microwave synthesizers possible. Four GHz is the highest clock rate achievable in production designs. These devices have the ability to drive TTL/CMOS logic, and the counter can be connected directly to single-chip frequency synthesizers controllers. A complete microwave sythesizer is formed by two chips and a voltage-controlled oscillator (VCO). The advantages of GaAs are discussed along with flip-flop basics, aspects of device fabrication, and the characteristics of GaAs MESAFETs. Attention is given to a GaAs prescaler usable for direct conversion, four kinds of flip-flops in a divide-by-two mode, and seven-stage binary ripple counters.

  1. Absolute measurement of {beta} emitters with a 4 {pi} counter; Mesure absolue des emetteurs {beta} au compteur 4 {pi}

    Energy Technology Data Exchange (ETDEWEB)

    Le Gallic, Y [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1959-06-15

    The object of this work is to investigate the conditions under which the activity of {beta}-emitting radionuclides may be measured with a maximum of precision, and as a result to study the relevant corrections. The various problems relating to activity measurements with a 4 {pi} counter have been examined successively: - comparison of 4 {pi}, GM and proportional counters; - study of the preparation of sources; - corrections on the counting of sources; - self-absorption; - correction for absorption. The precision obtained on these measurements varies from 1.2 to 3 per cent, with the result that the 4 {pi} counter can be considered a very satisfactory calibration instrument. (author) [French] Le but de ce travail est de rechercher les conditions permettant d'obtenir avec le maximum de precision, la mesure de l'activite des radionuclides se desintegrant par emission et par consequent d'etudier les corrections qui s'y rapportent. Nous avons examine successivement les differents problemes se rapportant aux mesures d'activite au compteur 4 {pi}: - Comparaison des compteurs 4 {pi}, GM et proportionnel; - etude de la preparation des sources; - corrections sur la numeration des sources; - auto-absorption; - correction d'absorption. La precision obtenue dans ces mesures, variant de 1,2 a 3 pour cent, on peut donc considerer le compteur 4 {pi} comme un instrument d'etalonnage tres satisfaisant. (auteur)

  2. Absolute measurement of {beta} emitters with a 4 {pi} counter; Mesure absolue des emetteurs {beta} au compteur 4 {pi}

    Energy Technology Data Exchange (ETDEWEB)

    Le Gallic, Y. [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1959-06-15

    The object of this work is to investigate the conditions under which the activity of {beta}-emitting radionuclides may be measured with a maximum of precision, and as a result to study the relevant corrections. The various problems relating to activity measurements with a 4 {pi} counter have been examined successively: - comparison of 4 {pi}, GM and proportional counters; - study of the preparation of sources; - corrections on the counting of sources; - self-absorption; - correction for absorption. The precision obtained on these measurements varies from 1.2 to 3 per cent, with the result that the 4 {pi} counter can be considered a very satisfactory calibration instrument. (author) [French] Le but de ce travail est de rechercher les conditions permettant d'obtenir avec le maximum de precision, la mesure de l'activite des radionuclides se desintegrant par emission et par consequent d'etudier les corrections qui s'y rapportent. Nous avons examine successivement les differents problemes se rapportant aux mesures d'activite au compteur 4 {pi}: - Comparaison des compteurs 4 {pi}, GM et proportionnel; - etude de la preparation des sources; - corrections sur la numeration des sources; - auto-absorption; - correction d'absorption. La precision obtenue dans ces mesures, variant de 1,2 a 3 pour cent, on peut donc considerer le compteur 4 {pi} comme un instrument d'etalonnage tres satisfaisant. (auteur)

  3. Analysis of Cherenkov counter efficiencies for E691

    International Nuclear Information System (INIS)

    Cremaldi, L.; Elliott, J.; Gibney, M.; Nauenberg, U.

    1985-01-01

    A program is outlined which simulates Cherenkov counters. The program can compute the effect of the magnetic field on the efficiencies of Cherenkov counters. It also tells what cone to mirror distance gives the highest collection efficiency and at which target position should the laser be placed to represent the direction of the actual Cherenkov light the mirror sees

  4. Geiger-Mueller haloid counter dead time dependence on counting rate

    International Nuclear Information System (INIS)

    Onishchenko, A.M.; Tsvetkov, A.A.

    1980-01-01

    The experimental dependences of the dead time of Geiger counters (SBM-19, SBM-20, SBM-21 and SGM-19) on the loading, are presented. The method of two sources has been used to determine the dead time counters of increased stability. The counters are switched on according to the usually used circuit of discrete counting with loading resistance of 50 MOhm and the separating capacity of 10 pF. Voltage pulses are given to the counting device with the time of resolution of 100 ns, discrimenation threshold 3 V, input resistance 3.6 Ω and the input capacity-15 pF. The time constant of the counter RC-circuit is 50 μs

  5. Construction techniques and working principles of external cathode Geiger-Mueller counters

    International Nuclear Information System (INIS)

    Sevegnani, Francisco Xavier

    1996-01-01

    In this paper, the construction technique and working principles of the external cathode Geiger-Mueller counter are described in detail. During the analysis of the behavior of these counters a new phenomena was observed, related to an increase int he background rate with the applied voltage. The experiments have also shown that the pulse amplitude of those counters decreases exponentially with the counting rate. The counters built with the techniques described in this paper has shown plateaus of about 1400 V with slope of 0,8%/100 V. (author)

  6. Sculptured platinum nanowire counter electrodes for dye-sensitized solar cells

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Hyeonseok [Department of Electrical Engineering, Pennsylvania State University, University Park 16802 (United States); Horn, Mark W., E-mail: MHorn@engr.psu.edu [Department of Engineering Science and Mechanics, Pennsylvania State University, University Park 16802-6812 (United States)

    2013-07-01

    Sculptured platinum nanowire thin films were formed by oblique angle electron beam evaporation with a 5° vapor incidence angle and incorporated as counter electrodes for dye-sensitized solar cells (DSSCs). For the comparison of the performance, bare fluorine doped tin oxide, planar Pt electrodes and counter electrodes treated with chloroplatinic acid were prepared. The sculptured Pt nanowire electrodes showed five times lower charge transfer resistance (0.121 [Ω∗cm{sup 2}]) than that of Pt planar electrode (0.578 [Ω∗cm{sup 2}]) and when the Pt nanowire electrodes are treated with an H{sub 2}PtCl{sub 6} solution have more than ten times lower charge transfer resistance (0.04025 [Ω∗cm{sup 2}]). Moreover, Pt nanowire films used as a counter electrode lead to enhancement in current density and efficiency in comparison with Pt planar counter electrodes. The conversion efficiency with planar electrodes was 5.1 [%] while the efficiency of DSSC with platinum nanowire counter electrodes reached to 5.63 [%] under AM 1.5 illumination. - Highlights: • Pt sculptured thin films (STFs) fabricated by electron beam evaporator. • The STFs featured higher roughness and lower charge transfer resistance. • Improved performance of dye-sensitized solar cells by Pt STFs counter electrodes.

  7. Development of a Mobile Ice Nucleus Counter

    Energy Technology Data Exchange (ETDEWEB)

    Kok, Gregory [Droplet Measurement Technologies, Boulder, CO (United States); Kulkarni, Gourihar [Droplet Measurement Technologies, Boulder, CO (United States)

    2014-07-10

    An ice nucleus counter has been constructed. The instrument uses built-in refrigeration systems for wall cooling. A cascade refrigeration system will allow the cold wall to operate as low as -70°C, and a single stage system can operate the warm wall at -45C. A unique optical particle counter has been constructed using polarization detection of the scattered light. This allows differentiation of the particles exiting the chamber to determine if they are ice or liquid.

  8. A recoil-proton fast-neutron counter telescope

    International Nuclear Information System (INIS)

    Pavan, P.; Toniolo, D.; Zago, G.; Zannoni, R.; Galeazzi, G.; Bressanini, G.

    1981-01-01

    A recoil-proton neutron counter telescope is described composed of a solid-state silicon transmission detector and a NE 102 A plastic scintillator, measuring the energy loss, the energy of the recoil protons and the time of flight between the two detectors. The counter exposed to monoenergetic neutron beams of energy from 6 to 20 MeV presents a low background and a moderate energy resolution. Its absolute efficiency is calculated up to 50 MeV. (author)

  9. Calibration and Monte Carlo modelling of neutron long counters

    CERN Document Server

    Tagziria, H

    2000-01-01

    The Monte Carlo technique has become a very powerful tool in radiation transport as full advantage is taken of enhanced cross-section data, more powerful computers and statistical techniques, together with better characterisation of neutron and photon source spectra. At the National Physical Laboratory, calculations using the Monte Carlo radiation transport code MCNP-4B have been combined with accurate measurements to characterise two long counters routinely used to standardise monoenergetic neutron fields. New and more accurate response function curves have been produced for both long counters. A novel approach using Monte Carlo methods has been developed, validated and used to model the response function of the counters and determine more accurately their effective centres, which have always been difficult to establish experimentally. Calculations and measurements agree well, especially for the De Pangher long counter for which details of the design and constructional material are well known. The sensitivit...

  10. INTRODUCING OVER THE COUNTER COUNSELING

    Directory of Open Access Journals (Sweden)

    Nataša Bakić-Mirić

    2009-01-01

    Full Text Available A pharmacist in today’s world has a great responsibility – to help and educate patients about diverse ways for effective self-treatment. Whereas self-care is becoming increasingly popular among patients today the availability of over-the-counter medications makes it possible for patients to treat numerous conditions on their own but still under the supervision of a healthcare provider. During the pharmacist-patient encounter, the pharmacist’s obligation is to evaluate the patient’s medical condition, provide proper advice and counsel the patient on the proper course of treatment to be taken. Also by employing effective over the counter (OTC counseling as the most proper means in a pharmacist/patient communication process and, accordingly, rapport building in the OTC area, the pharmacist needs to demonstrate high energy, enthusiasm, respect, empathy, know-how of sensitive intercultural issues alongside personal appearance, body language, eye contact that all together make his/her personal “signature”. Accordingly, apart from patient education, the primary objective of OTC counseling becomes to educate pharmacists on basic principles used in assisting patients in the selection of over-the-counter (OTC products, provide examples of proper communication techniques for effective patient counseling concerning the OTC products (i.e. dosage, administration technique, storage, food and beverage interaction, monitoring etc where the pharmacist plays the key role in helping patients maximize their pharmaceutical care.

  11. About the distribution of delays in G.M counters

    International Nuclear Information System (INIS)

    Picard, E.; Rogozinski, A.

    1954-01-01

    We measure, with an oscillograph method the global time that pass between the time that a particle in a determined region of the studied counter and the answer of the amplifier associated to the counter. This delay is composed of the latency time T l and the T q delay, that result from the rise time finished of the impulse and whose value depends of the sensitivity threshold of the amplifier. The selection of (cosmic) particles generating discharge in the studied counter is obtained thanks to a telescope of two meters in coincidence whose opening is limited by a group of four counters in anti-coincidence with the first. The meter is arranged so that the median plan of the telescope crosses to a variable distance d of his axial thread. The measures have been done for different securities of the distance d and of the over-voltage V s applied to the counter. The results show that the statistical distribution of the delays is more spread especially when d is bigger and V s more reduced. The average values of the observed delays vary of 7.10 -8 s for d = 0 and V s es = 200 V, to 90.10 -8 s for d = 1,9 cm and V s = 50 V. The mobility of an free electron within the gaseous mixture filling the counter under a pressure of 10 cm.Hg was found equal: (2,1 ±0,2).10 4 cm 2 .s -1 .V -1 . (author) [fr

  12. Counter-Stereotypes and Feminism Promote Leadership Aspirations in Highly Identified Women

    Science.gov (United States)

    Leicht, Carola; Gocłowska, Małgorzata A.; Van Breen, Jolien A.; de Lemus, Soledad; Randsley de Moura, Georgina

    2017-01-01

    Although women who highly identify with other women are more susceptible to stereotype threat effects, women's identification might associate with greater leadership aspirations contingent on (1) counter-stereotype salience and (2) feminist identification. When gender counter-stereotypes are salient, women's identification should associate with greater leadership aspiration regardless of feminism, while when gender stereotypes are salient, women's identification would predict greater leadership aspirations contingent on a high level of feminist identification. In our study US-based women (N = 208) attended to gender stereotypic (vs. counter-stereotypic) content. We measured identification with women and identification with feminism, and, following the manipulation, leadership aspirations in an imagined work scenario. The interaction between identification with women, identification with feminism, and attention to stereotypes (vs. counter-stereotypes) significantly predicted leadership aspirations. In the counter-stereotypic condition women's identification associated with greater leadership aspirations regardless of feminist identification. In the stereotypic condition women's identification predicted leadership aspirations only at high levels of feminist identification. We conclude that salient counter-stereotypes and a strong identification with feminism may help high women identifiers increase their leadership aspirations. PMID:28626437

  13. Counter-Stereotypes and Feminism Promote Leadership Aspirations in Highly Identified Women.

    Science.gov (United States)

    Leicht, Carola; Gocłowska, Małgorzata A; Van Breen, Jolien A; de Lemus, Soledad; Randsley de Moura, Georgina

    2017-01-01

    Although women who highly identify with other women are more susceptible to stereotype threat effects, women's identification might associate with greater leadership aspirations contingent on (1) counter-stereotype salience and (2) feminist identification. When gender counter-stereotypes are salient, women's identification should associate with greater leadership aspiration regardless of feminism, while when gender stereotypes are salient, women's identification would predict greater leadership aspirations contingent on a high level of feminist identification. In our study US-based women ( N = 208) attended to gender stereotypic (vs. counter-stereotypic) content. We measured identification with women and identification with feminism, and, following the manipulation, leadership aspirations in an imagined work scenario. The interaction between identification with women, identification with feminism, and attention to stereotypes (vs. counter-stereotypes) significantly predicted leadership aspirations. In the counter-stereotypic condition women's identification associated with greater leadership aspirations regardless of feminist identification. In the stereotypic condition women's identification predicted leadership aspirations only at high levels of feminist identification. We conclude that salient counter-stereotypes and a strong identification with feminism may help high women identifiers increase their leadership aspirations.

  14. Counter-Stereotypes and Feminism Promote Leadership Aspirations in Highly Identified Women

    Directory of Open Access Journals (Sweden)

    Carola Leicht

    2017-06-01

    Full Text Available Although women who highly identify with other women are more susceptible to stereotype threat effects, women's identification might associate with greater leadership aspirations contingent on (1 counter-stereotype salience and (2 feminist identification. When gender counter-stereotypes are salient, women's identification should associate with greater leadership aspiration regardless of feminism, while when gender stereotypes are salient, women's identification would predict greater leadership aspirations contingent on a high level of feminist identification. In our study US-based women (N = 208 attended to gender stereotypic (vs. counter-stereotypic content. We measured identification with women and identification with feminism, and, following the manipulation, leadership aspirations in an imagined work scenario. The interaction between identification with women, identification with feminism, and attention to stereotypes (vs. counter-stereotypes significantly predicted leadership aspirations. In the counter-stereotypic condition women's identification associated with greater leadership aspirations regardless of feminist identification. In the stereotypic condition women's identification predicted leadership aspirations only at high levels of feminist identification. We conclude that salient counter-stereotypes and a strong identification with feminism may help high women identifiers increase their leadership aspirations.

  15. A semiconductor counter telescope for neutron reaction studies

    Energy Technology Data Exchange (ETDEWEB)

    Lalovic, B I; Ajdacic, V S [Institute of nuclear sciences Boris Kidric, Vinca, Beograd (Yugoslavia)

    1963-12-15

    A counter telescope consisting of two or three semiconductor counters for {delta}E/{delta}x vs. E analysis was made for studying nuclear reactions induced by 14.4 MeV neutrons. Various factors important for the telescope performance are discussed in details and some solutions for getting an optimum resolution and a low background are given. Protons, deuterons and alpha particles resulting from scattering and reactions of 14.4 MeV neutrons on deuterium, tritium, praseodymium and niobium were detected, and pulses from the counters recorded on a two-dimensional analyzer. These experiments have shown that the telescope compares favorably with other types of telescopes with regards to the upper limit of neutron flux which can be used, (DELTADELTA)x and E resolution, versatility and compactness (author)

  16. Carbon Nanotubes Counter Electrode for Dye-Sensitized Solar Cells Application

    Directory of Open Access Journals (Sweden)

    Drygała A.

    2016-06-01

    Full Text Available The influence of the carbon nanotubes counter electrode deposited on the FTO glass substrates on the structure and optoelectrical properties of dye-sensitized solar cells counter electrode (CE was analysed. Carbon materials have been applied in DSSC s in order to produce low-cost solar cells with reasonable efficiency. Platinum is a preferred material for the counter electrode because of its high conductivity and catalytic activity. However, the costs of manufacturing of the platinum counter electrode limit its use to large-scale applications in solar cells. This paper presents the results of examining the structure and properties of the studied layers, defining optical properties of conductive layers and electrical properties of dye-sensitized solar cells manufactured with the use of carbon nanotubes.

  17. Towards a Theory of Fear Management in the Counter-Terrorism Domain

    Directory of Open Access Journals (Sweden)

    Edwin Bakker

    2014-01-01

    Full Text Available Since 9/11, the state of the art in counter-terrorism research, counter-terorism measures and counter-terrorism impacts has taken off. Nevertheless, countering terrorism as a branch of fear management is still a discipline to be developed. In this Research Paper, authors Prof. Dr. Edwin Bakker and Prof. Dr. Beatrice de Graaf attempt to lessen this gap. The Paper identifies and analyses governmental approaches to managing fear in relation to terrorist incidents. It is a stocktaking approach, offering a preliminary oversight of some central aspects and pointers on the way forward when constructing and testing such a theory.

  18. The effect of counter-trading on competition in electricity markets

    International Nuclear Information System (INIS)

    Dijk, Justin; Willems, Bert

    2011-01-01

    In a competitive electricity market, nodal pricing is the most efficient way to manage congestion. Counter-trading is inefficient as it gives the wrong long term signals for entry and exit of power plants. However, in a non-competitive market, additional entry will improve the competitiveness of the market, and will increase social benefit by reducing price-cost margins. This paper studies whether the potential pro-competitive entry effects could make counter-trading more efficient than nodal pricing. We find that this is unlikely to be the case, and expect counter-trading to have a negative effect on overall welfare. The potential benefits of additional competition (more competitive prices and lower production cost) do not outweigh the distortions (additional investment cost for the entrant, and socialization of the congestion cost to final consumers). - Research highlights: → 'Counter-trading' and 'nodal pricing' manage congestion in electric grids. → Nodal pricing gives superior locational prices. → Counter-trading induces extra investments in regions with a production surplus. → Extra investments improve competition, but are expected to be socially inefficient.

  19. Counter terms for low momentum nucleon-nucleon interactions

    International Nuclear Information System (INIS)

    Holt, Jason D.; Kuo, T.T.S.; Brown, G.E.; Bogner, Scott K.

    2004-01-01

    There is much current interest in treating low energy nuclear physics using the renormalization group (RG) and effective field theory (EFT). Inspired by this RG-EFT approach, we study a low-momentum nucleon-nucleon (NN) interaction, V low-k , obtained by integrating out the fast modes down to the scale Λ∼2 fm -1 . Since NN experiments can only determine the effective interaction in this low momentum region, our chief purpose is to find such an interaction for complex nuclei whose typical momenta lie below this scale. In this paper we find that V low-k can be highly satisfactorily accounted for by the counter terms corresponding to a short range effective interaction. The coefficients C n of the power series expansion ΣC n q n for the counter terms have been accurately determined, and results derived from several meson-exchange NN interaction models are compared. The counter terms are found to be important only for the S, P and D partial waves. Scaling behavior of the counter terms is studied. Finally we discuss the use of these methods for computing shell model matrix elements

  20. Proportionality for Military Leaders

    National Research Council Canada - National Science Library

    Brown, Gary D

    2000-01-01

    .... Especially lacking is a realization that there are four distinct types of proportionality. In determining whether a particular resort to war is just, national leaders must consider the proportionality of the conflict (i.e...

  1. Irradiated fuel bundle counter

    International Nuclear Information System (INIS)

    Campbell, J.W.; Todd, J.L.

    1975-01-01

    The design of a prototype safeguards instrument for determining the number of irradiated fuel assemblies leaving an on-power refueled reactor is described. Design details include radiation detection techniques, data processing and display, unattended operation capabilities and data security methods. Development and operating history of the bundle counter is reported

  2. Constant sensitivity circuit for solid state nuclear radiation counters

    International Nuclear Information System (INIS)

    Kronenberg, S.; Erkkila, B.

    1985-01-01

    The utilization of solid state counters in tactical radiological instruments for measuring intensities and doses of fallout gamma rays offers advantages over Geiger-Mueller (GM) counters such as a much wider dynamic range and low operating voltages. Their very small size is suitable for use in miniaturized equipment. However, these devices have a serious problem if used in a mixed, fast neutron/gamma environment such as is encountered e.g. in a battlefield where tactical nuclear weapons are used and neutrons, prompt, initial gammas and fallout gammas are killing factors of comparable importance. Exposure to fast neutrons reduces seriously their sensitivity. This makes the solid state counters at this time unacceptable for use in Army tactical surveillance equipment and in other applications where according to requirements the performance must not be impaired by exposure to fast neutrons. It seems to be possible to reduce to some extent this neutron generated damage by improving the crystal counters

  3. Analysis of counter-rotating wind turbines

    DEFF Research Database (Denmark)

    Shen, Wen Zhong; Zakkam, Vinod Arun Kumar; Sørensen, Jens Nørkær

    2007-01-01

    This paper presents a study on the performance of a wind turbine with two counter-rotating (CRWT) rotors. The characteristics of the two counter-rotating rotors are on a 3-bladed Nordtank 500 kW rotor. The analysis has been carried out by using an Actuator Line technique implemented in the Navier......-Stokes code EllipSys3D. The analysis shows that the Annual Energy Production can be increased to about 43.5 %, as compared to a wind turbine with a single rotor. In order to determine the optimal settings of the CRWT turbine, parameters such as distance between two rotors and rotational speed have been...

  4. Calibration of nuclear medicine gamma counters

    International Nuclear Information System (INIS)

    Orlic, M.; Spasic-Jokic, V.; Jovanovic, M.; Vranjes, S. . E-mail address of corresponding author: morlic@vin.bg.ac.yu; Orlic, M.)

    2005-01-01

    In this paper the practical problem of nuclear medicine gamma counters calibration has been solved by using dose calibrators CRC-15R with standard error ±5%. The samples from technetium generators have been measured both by dose calibrators CRC-15R and gamma counter ICN Gamma 3.33 taking into account decay correction. Only the linear part of the curve has practical meaning. The advantage of this procedure satisfies the requirements from international standards: the calibration of sources used for medical exposure be traceable to a standard dosimetry laboratory and radiopharmaceuticals for nuclear medicine procedures be calibrated in terms of activity of the radiopharmaceutical to be administered. (author)

  5. Development of DUPIC safeguards neutron counter

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Young Gil; Cha, Hong Ryul; Kim, Ho Dong; Hong, Jong Sook; Kang, Hee Young

    1999-08-01

    KAERI, in cooperation with LANL, developed DSNC (DUPIC Safeguards Neutron Counter) for safeguards implementing on DUPIC process which is under development by KAERI for direct use of spent PWR fuel in CANDU reactors. DSNC is a well-type neutron coincidence counter with substantial shielding to protect system from high gamma radiation of spent fuel. General development procedures in terms of design, manufacturing, fabrication, cold and hot test, performance test for DSNC authentication by KAERI-IAEA-LANL are described in this report. It is expected that the techniques related DSNC development and associated neutron detection and evaluation method could be applied for safeguards improvement. (Author). 20 refs., 16 tabs. 98 figs.

  6. Neutron coincidence counter for MOX fuel pins in storage trays: users' manual

    International Nuclear Information System (INIS)

    Cowder, L.; Menlove, H.

    1982-08-01

    The neutron coincidence counter for measurement of mixed-oxide fuel pins in storage trays is described. The special detector head has been designed so that the detectors, high-voltage junction boxes, and electronics are interchangeable with those of the high-level neutron coincidence counter system. This manual describes the system components and the operation and maintenance of the counter. The counter was developed at Los Alamos National Laboratory for in-plant inspection applications by the International Atomic Energy Agency

  7. Counter-terrorism strategies in Indonesia, Algeria and Saudi Arabia

    NARCIS (Netherlands)

    Meijer, R.; Hasan, Noorhaidi; Hendriks, B.; Janssen, F.

    2012-01-01

    This report is the result of a year-long study, conducted from March 2010 to March 2011, of the counter-terrorist strategies of three countries: Indonesia, Algeria and Saudi Arabia. The aim of this study was to acquire insight into the counter-terrorist strategies of these countries, to analyse

  8. Design and Implementation of MOD-6 Synchronous Counter using VHDL

    Directory of Open Access Journals (Sweden)

    P. Y. Dibal

    2013-08-01

    Full Text Available This paper deals with the design of a MOD-6 synchronous counter using VHDL (VHSIC Hardware Description Language. The VHSIC stands for Very High Speed Integrated Circuit. Using this approach, the behaviour of the counter is the most important aspect of the design. In the first section, the paper introduced counters in general, and their areas of specialization, like frequency synthesizers. The synchronous counter was then introduced, stating the behaviour of the flip-flops that make the counter. The modulus of a counter was defined. In the second section, the Xilinx ISE (Integrated Simulation Environment and the ISIM (Integrated Simulator were presented and briefly described with their respective snapshots. The structure of a typical VHDL code was presented, which included LIBRARY, ENTITY, and ARCHITECTURE. Each of these structures was then briefly described. The main work in this paper was then presented. The count sequence steps were stated as . VHDL was used to model the counter to count through six steps, outputting count values according to desired steps. The hardware implementation of the design was presented, where the implementation process was described, with a supporting diagram, followed by the floor-planning technique, in which the PORTS described in the VHDL design were assigned to the physical pins of the XC3S1000 FPGA (Field Programmable Gate Array chip. The final steps of the hardware implementation process were then presented. These include bitstream generation and download to target device. The third section of the paper presented the results obtained. Simulation/timing results of the design were presented, showing the output of the counter at each state with respect to the clock signal. The result of the synthesis of the design was presented, which showed the FPGA area with the exact location of the pins on the FPGA chip. Finally, the fourth section presented the conclusion arrived at, in respect of the design that was carried

  9. Prescription Drugs, Over-the-Counter Drugs, Supplements and Herbal Products

    Science.gov (United States)

    ... at risk? Zika virus and pregnancy Folic acid Medicine safety and pregnancy Birth defects prevention Learn how ... the-counter drugs, supplements and herbal products Prescription drugs, over-the-counter drugs, supplements and herbal products ...

  10. Whole body counters: types, performance and uses

    International Nuclear Information System (INIS)

    Jales, R.L.C.

    1983-01-01

    The present monograph deals with Whole Counters, since its definition, evolution, performance, clinical indications and results. Scintillation crystals detection systems were described as well as scintillant solutions, plastic scintillations, and gaseous detectors, including its interplay forms and basal characteristics. Geometric arrangements of standard chair, arc and hammock, arrangements with scintillant solutions and plastic scintillations, as well as special geometric arrangements were equally commented. Clinic and experimental studies were also dealt with Whole Body Counters, giving examples with potassium, iron vitamin B 12 and albumin. (author)

  11. Irradiated fuel bundle counter

    International Nuclear Information System (INIS)

    Campbell, J.W.; Todd, J.L.

    1975-01-01

    The design of a prototype safeguards instrument for determining the number of irradiated fuel assemblies leaving an on-power refueled reactor is described. Design details include radiation detection techniques, data processing and display, unattended operation capabilities and data security methods. Development and operating history of the bundle counter is reported. (U.S.)

  12. A gaseous scintillation counter filled with He3 for neutron spectrometry

    International Nuclear Information System (INIS)

    Baldin, S.A.; Matveev, V.V.

    1962-01-01

    The paper describes a gas plant and gaseous scintillation counter, and gives the results of experiments on the recording and spectrometry of neutron beams using a gaseous scintillation counter filled with a mixture of 10% xenene and 90% helium-3 at an overall pressure of 20 ata. Data are given on the design of the gas plant, which makes it possible to operate the counter continuously over long periods of time, as well as providing the required gas mixtures at overall pressures of up to 60 atm and ensuring constant freedom of the gas from contamination. In addition, the paper presents the results of research on the counter's energy resolution and linearity at different energy levels and indicates its efficiency in gamma fields of intensity up to 3 r/h; the possibility of extending the working energy-range of gaseous scintillation counters filled with helium-3 is also considered. (author) [fr

  13. A miniature spark counter for public communication and education

    International Nuclear Information System (INIS)

    Mao, C.H.; Weng, P.S.

    1987-01-01

    The fabrication of a miniature spark counter for public communication and education using naturally occurring radon as a radioactive source without involving any man-made radioactivity is described. The battery-powered miniature spark counter weighs 2.07 kg with a volume of 4.844 x 10/sup -4/ m/sup 3/. The circuitry consists of seven major components: timer, high-voltage power supply, attenuator, noninverting amplifier, low-pass filter, one-shot generator, and counter. Cellulose nitrate films irradiated with alpha particles from radon emanating from soil were etched and counted. The visible sparks during counting are rather heuristic, which can be used to demonstrate naturally occurring radioactivity in classrooms or showplaces

  14. Hardware support for collecting performance counters directly to memory

    Science.gov (United States)

    Gara, Alan; Salapura, Valentina; Wisniewski, Robert W.

    2012-09-25

    Hardware support for collecting performance counters directly to memory, in one aspect, may include a plurality of performance counters operable to collect one or more counts of one or more selected activities. A first storage element may be operable to store an address of a memory location. A second storage element may be operable to store a value indicating whether the hardware should begin copying. A state machine may be operable to detect the value in the second storage element and trigger hardware copying of data in selected one or more of the plurality of performance counters to the memory location whose address is stored in the first storage element.

  15. A test of planar spark counters at the PEP storage ring

    International Nuclear Information System (INIS)

    Atwood, W.B.; Bowden, G.B.; Bonneaud, G.R.; Klem, D.E.; Ogawa, A.; Pestov, Yu.N.; Pitthan, R.; Sugahara, R.

    1983-01-01

    A test of planar spar counters (PSCs) at the PEP electron-positron storage ring showed the following. PSCs can be used under harsh experimental conditions without long term degradation of resolution. On-line time-of-flight resolutions were below 200 ps, coordinate resolutions better than 4 mm, both limited to these values by the resistivity of the semiconducting glass and the electronics used. The best single counter time resolution under realistic conditions at the storage ring was 76 ps. Pulse height was a good indicator of the number of particles striking a counter. Subsequent measurements using cosmis rays gave a single counter time resolution of 50 ps. (orig.)

  16. Possibility of experiments using radiation counters for test electron stability and Pauli principle violation in atoms

    International Nuclear Information System (INIS)

    Barabash, A.S.

    1989-01-01

    Capabilities of modern radiation detectors for investigation into electron stability and possible violation of Pauli principle in atoms are discussed. For experimental searches of electron instability the following low-background devices are used: scintillation NaI-detectors, semiconducting detectors of enriched germanium, emission chamber, multisection proportional counter and low-temperature detectors. It is ascertained that using modern low-background devices applying the earlier enumerated detectors, it is possible to achieve sensitivity of the order of 10 24 -10 25 years for the electron lifetime relatively to its decay and Pauli principle violation in atoms. Experiments with sensitivity of ∼ 10 26 -10 27 can be realized in massive low-temperature detectors, developed for neutrino physics. 28 refs; 1 fig

  17. Body counter

    International Nuclear Information System (INIS)

    Koeppe, P.

    1975-01-01

    The paper gives a survey on some applications of the whole body counter in clinical practice and a critical study of its application as a routine testing method. Remarks on the necessary precautions are followed by a more detailed discussion of the determination of the natural potassium content, the iron metabolism, the vitamin B12 test, investigations of the metabolism of the bone using 47 Ca and 85 Sr, investigations with iodine and iodine-labelled substances, clearance investigations (in particular the 51 Cr EDTA clearance test), as well as the possibilities of neutron activation in vivo. (ORU/AK) [de

  18. Discharge quenching circuit for counters

    International Nuclear Information System (INIS)

    Karasik, A.S.

    1982-01-01

    A circuit for quenching discharges in gas-discharge detectors with working voltage of 3-5 kV based on transistors operating in the avalanche mode is described. The quenching circuit consists of a coordinating emitter follower, amplifier-shaper for avalanche key cascade control which changes potential on the counter electrodes and a shaper of discharge quenching duration. The emitter follower is assembled according to a widely used flowsheet with two transistors. The circuit permits to obtain a rectangular quenching pulse with front of 100 ns and an amplitude of up to 3.2 kV at duration of 500 μm-8 ms. Application of the quenching circuit described permits to obtain countering characteristics with the slope less than or equal to 0.02%/V and plateau extent greater than or equal to 300 V [ru

  19. Counter-transference reactions contributing to completed suicide.

    Science.gov (United States)

    Modestin, J

    1987-12-01

    Counter-transference reactions are frequently elicited while treating suicidal patients and they may contribute to the patient's committing suicide. Therapeutic constellations including the failure of the therapist to (1) cope with the patient's aggressiveness, (2) tolerate the patient's dependency, (3) handle the erotic transference adequately and (4) preserve loyalty towards the patient; they have all been identified as being responsible for a therapeutic impasse with fatal consequences. Knowledge of the therapeutic constellations especially prone to facilitate negative counter-transference reactions may help the therapist to master them effectively.

  20. Interaction between counter-streaming ion-acoustic solitons and the Langmuir waves

    International Nuclear Information System (INIS)

    Basovich, A.Ya.; Gromov, E.M.; Talanov, V.I.

    1984-01-01

    The interaction between strong counter-streaming ion-acoustic solitons and the Langmuir waves is considered. At first the Langmuir waves spectrum transformation by counter-streaming ion-acoustic solutions of a preset amplitude e has been found. An increase in the frequency and number of the Langmuir waves due to the Doppler effect in the course of multiple reflection from the f front soliton slope has been determined and the wave number range in which the confinement of the Langmuir waves by counter-streaning solitons is possible has s been found. It is shown that the time of the Langmuir wave transformation into the short-wave region under the effect of the counter-streaming soliton may y be short as compared with the time of the Langmuir wave diffusion into the Landau damping region under the effect of random fields of ion-acoustic waves. In the adiabatic fpproximation changes in the counter-streaming ion acoustic parameters of solitons owing to the Langmuir waves have been

  1. Solidarity and Recognition: Geographies of Counter-globalism

    Directory of Open Access Journals (Sweden)

    James Goodman

    2006-02-01

    Full Text Available Globalism is a contested concept, but perhaps best understood as a spatial strategy, which disempowers those unable to transcend the fixity of place and social context. Under globalism fluidity becomes a key source of power, enabling the powerful to liquefy assets, to disembed, and thereby displace, political, social or ecological impacts. The infrastructures of globalism enable the disembodied extension of power across territory, to the extent that one model, universally applicable for all societies, is positioned as supreme. The only possible challenge to globalism perhaps, is through a similarly disembedded counter-movement, that mirrors the global reach and power of mainstream globalism. The praxis of counter-globalist movements suggests a different tendency, one that centres on the assertion of particularity against universality. Expressed in the legitimacy of ‘many worlds’ against ‘one world’ globalism, such resistance centres on exposing the material effects and foregrounding concrete and material experiences of globalism. Movements mobilise against the disembodied logic of globalism on the basis of co-presence and inter-subjectivity, and are embedded in relational concepts of selfhood. They are often intensely embodied and are radically emplaced through militant localism and trans-local dialogue. Counter-globalism thus does not seek to defeat geography; rather it embraces it, as the starting-point of mobilisation. The starting point of this article is thus to analyse globalism as a spatial strategy, a strategy of displacement grounded in material power. Globalism thus signifies the capacity to exploit and dominate at distance, from the sanctity of corporate boardrooms, military briefings and media cutting rooms. The claim is to universal market, military and normative power, but the impact is of extended and deepened division. Centres of power appear more as islands, or enclaves, defined against the backwash effects of counter

  2. Evaluation of fat-free mass by whole-body counter in Japanese healthy young adults

    International Nuclear Information System (INIS)

    Morita, N.; Takamura, N.; Murakami, T.; Jo, O.; Aoyagi, K.; Yamashita, S.; Okumura, Y.

    2007-01-01

    Whole-body counters (WBCs) are special instruments for measuring internal irradiation doses and are usually housed within or around nuclear facilities in the event of unexpected radiation emergencies. As a substantial proportion of total body potassium (TBK) is found in fat-free mass (FFM), FFM volume can be predicted from WBC-measured 40 K. We screened TBK in Japanese healthy young adults using a WBC and found strong linear correlations between TBK and lean body mass (LBM) and body mass index (r = 0.97, P<0.01 and r = 0.47, P<0.01, respectively). Multiple linear regression analysis, following adjustments for sex, indicates that only LBM has a significant correlation with TBK (P<0.01). These results strongly support the feasibility of using WBCs for estimating FFM. (authors)

  3. Transparent platinum counter electrode for efficient semi-transparent dye-sensitized solar cells

    Energy Technology Data Exchange (ETDEWEB)

    Iefanova, Anastasiia; Nepal, Jeevan; Poudel, Prashant; Davoux, Daren; Gautam, Umesh [Electrical Engineering and Computer Science Department, South Dakota State University, Brookings, SD 57006 (United States); Mallam, Venkataiah [Chemistry and Biochemistry Department, South Dakota State University, Brookings, SD 57006 (United States); Qiao, Qiquan [Electrical Engineering and Computer Science Department, South Dakota State University, Brookings, SD 57006 (United States); Logue, Brian [Chemistry and Biochemistry Department, South Dakota State University, Brookings, SD 57006 (United States); Baroughi, Mahdi Farrokh, E-mail: m.farrokhbaroughi@sdstate.edu [Electrical Engineering and Computer Science Department, South Dakota State University, Brookings, SD 57006 (United States)

    2014-07-01

    A method for fabrication of highly transparent platinum counter electrodes (CEs) has been developed based on spray coating of Pt nanoparticles (NPs) on hot substrates. This method leads to 86% reduction in Pt consumption reducing the Pt cost per peak watt of counter electrode from $0.79/Wp down to $0.11/Wp compared to the conventional Pt counter electrodes made by sputter deposition. The simplicity and low cost of this method provide a basis for an up-scalable fabrication process. The Pt NP layer is over 88% transparent, leading to overall transparency of 80% when incorporated with indium tin oxide/glass substrates for functional counter electrodes. This counter electrode exhibits a large surface area and high catalytic activity, comparable to that of the conventional opaque CEs. Semi-transparent dye-sensitized solar cells fabricated based on this counter electrode showed 6.17% power conversion efficiency. - Highlights: • Counter electrode (CE) prepared by spraying nanoparticle (NP) Pt on hot substrate. • Low cost and scalable fabrication process of CE. • The spray deposited CE uses 10 times less Pt compared to the sputtering method. • The CE is 80% transparent and exhibits a large surface and high catalytic activity. • A semitransparent dye-sensitized solar cell with Pt NP CE was 6.17% efficient.

  4. Background compensated GM counter for the measurement of low level #betta#-activity

    International Nuclear Information System (INIS)

    Mori, C.; Kumanomido, H.; Watanabe, T.

    1983-01-01

    When low level activity of a #betta#-ray source or surface contamination is to be measured with a GM counter, it is desirable to obtain a net count without background count through a single measurement. An end-window GM counter for such a purpose was constructed. The counter has a diaphragm to divide it into two parts. The front part, the window side, can detect #betta#-rays and background radiations, while the rear part only detects background, since #betta#-rays coming through the front are absorbed by the diaphragm. In the counter type I, the sensitive volumes of the two parts are the same and the anode wire of the front is connected to that of the rear through an electric resistor which leads to yielding different pulse heights and rise times. The net count of #betta#-rays can be obtained through a single measurement by subtracting the count in the rear part from that in the front part. In the counter type II, the lengths of the anode wires of the two parts are different, which gives rise to different pulse heights. With a background compensated GM counter, it is possible to shorten the measuring time, keeping nearly the same accuracy compared with a conventional GM counter. (orig.)

  5. Monte Carlo simulation of neutron counters for safeguards applications

    International Nuclear Information System (INIS)

    Looman, Marc; Peerani, Paolo; Tagziria, Hamid

    2009-01-01

    MCNP-PTA is a new Monte Carlo code for the simulation of neutron counters for nuclear safeguards applications developed at the Joint Research Centre (JRC) in Ispra (Italy). After some preliminary considerations outlining the general aspects involved in the computational modelling of neutron counters, this paper describes the specific details and approximations which make up the basis of the model implemented in the code. One of the major improvements allowed by the use of Monte Carlo simulation is a considerable reduction in both the experimental work and in the reference materials required for the calibration of the instruments. This new approach to the calibration of counters using Monte Carlo simulation techniques is also discussed.

  6. Measurements of Radon Concentration in Yemen Using Spark Counter

    International Nuclear Information System (INIS)

    Arafa, W.; Abou-Leila, M.; Hafiz, M.E.; Al-Glal, N.

    2011-01-01

    Spark counter has been designed and realized and the optimum applied voltage was found to be 600 V. Excellent consistent agreements was observed between counted number of tracks by spark counter and reading by optical microscope. Radon concentration in some houses in Sana'a and Hodeidah cities in Yemen had been performed using LR-115 SSNTD and spark counter system. The average radon concentration in both cities was far lower the alert value. The results showed that radon concentration in the metropolitan area Sana'a was higher than that in Hodeidah city. Also, it was observed that old residential houses had higher levels of radon concentrations have compared to newly built houses in the metropolitan area Sana'a

  7. High-level neutron coincidence counter (HLNCC): users' manual

    International Nuclear Information System (INIS)

    Krick, M.S.; Menlove, H.O.

    1979-06-01

    This manual describes the portable High-Level Neutron Coincidence Counter (HLNCC) developed at the Los Alamos Scientific Laboratory (LASL) for the assay of plutonium, particularly by inspectors of the International Atomic Energy Agency (IAEA). The counter is designed for the measurement of the effective 240 Pu mass in plutonium samples which may have a high plutonium content. The following topics are discussed: principle of operation, description of the system, operating procedures, and applications

  8. A comprehensive test specification for pulse fission counters

    Energy Technology Data Exchange (ETDEWEB)

    Roberts, D L [Control and Instrumentation Division, Atomic Energy Establishment, Winfrith, Dorchester, Dorset (United Kingdom)

    1962-02-15

    The following test specification is based on the memorandum AERE - M 728 which it now replaces It contains a standard acceptance test procedure for the many U.K.A.E.A, designed pulse fission counters now commercially available. This test specification may be used for any pulse fission counter provided a specification sheet as shown in Appendix 3 is supplied to the contractor quoting this report and including specified values for the measured quantities. (author)

  9. Development of aerogel Cherenkov counters at Novosibirsk

    International Nuclear Information System (INIS)

    Barnyakov, A.Yu.; Barnyakov, M.Yu.; Baehr, J.; Bellunato, T.; Beloborodov, K.I.; Bobrovnikov, V.S.; Buzykaev, A.R.; Calvi, M.; Danilyuk, A.F.; Djordjadze, V.; Golubev, V.B.; Kononov, S.A.; Kravchenko, E.A.; Lipka, D.; Matteuzzi, C.; Musy, M.; Onuchin, A.P.; Perego, D.; Rodiakin, V.A.; Savinov, G.A.; Serednyakov, S.I.; Shamov, A.G.; Stephan, F.; Tayursky, V.A.; Vorobiov, A.I.

    2006-01-01

    The work on aerogel Cherenkov counters was started in Novosibirsk in 1986. Production of aerogels with refractive indices of 1.006-1.13 and thicknesses of blocks up to 50mm was developed. The light absorption length at 400nm is 5-7m, the scattering length is 4-5cm. By these parameters, the Novosibirsk aerogel is one of the best in the world. The ASHIPH Cherenkov counters with light collection on wavelength shifters have been developed. The ASHIPH system of the KEDR detector contains 1000l of aerogel. The π/K separation is 4.5σ. A project of ASHIPH counters for the SND detector has been developed. Aerogel RICH for LHCb gives a possibility to identify hadrons in the momentum range of 2-10GeV/c. The Novosibirsk group is developing an aerogel RICH for the endcap for the SuperBaBar project. Calculations performed by a group of physicists from Novosibirsk and DESY-Zeuthen have shown that aerogel radiators enable to achieve time resolution up to 20fs

  10. Counter diffusion of zinc and iron in alluvial soil

    International Nuclear Information System (INIS)

    Rattan, R.K.; Deb, D.L.

    1980-01-01

    Half cell technique showed that an increase in moisture tension and CaCO 3 content caused reduction in the counter diffusion coefficients of zinc and iron in an alluvial soil. Increases in bulk density, ambient temperature and concentration of synthetic chelating agents e.g. EDTA and DTPA increased the counter diffusion coefficients of both zinc and iron. (author)

  11. Activated graphene nanoplatelets as a counter electrode for dye-sensitized solar cells

    Energy Technology Data Exchange (ETDEWEB)

    Gong, Jiawei [Center for Advanced Photovoltaics, Department of Electrical Engineering, South Dakota State University, Brookings, South Dakota 57007 (United States); Department of Mechanical Engineering, North Dakota State University, Fargo, North Dakota 58102 (United States); Zhou, Zhengping; Qiao, Qiquan, E-mail: qiquan.qiao@sdstate.edu [Center for Advanced Photovoltaics, Department of Electrical Engineering, South Dakota State University, Brookings, South Dakota 57007 (United States); Sumathy, K. [Department of Mechanical Engineering, North Dakota State University, Fargo, North Dakota 58102 (United States); Yang, Huojun [Department of Construction Management and Engineering, North Dakota State University, Fargo, North Dakota 58102 (United States)

    2016-04-07

    Activated graphene nanoplatelets (aGNPs) prepared by a hydrothermal method using KOH as activating agent were used as counter electrode for high efficiency dye-sensitized solar cells (DSSCs). After the KOH activation, the scanning electron microscopy image shows that aGNPs demonstrate a more curled, rough, and porous morphology which could contain both micro- and mesopores. The KOH activation changed the stacked layers of GNPs to a more crumpled and curved morphology. The microstructure of large pores significantly increased the electrode surface area and roughness, leading to the high electrocatalytic activity for triiodide reduction at the counter electrode. The DSSCs fabricated using aGNP as counter electrodes were tested under standard AM 1.5 illumination with an intensity of 91.5 mW/cm{sup 2}. The device achieved an overall power conversion efficiency of 7.7%, which is comparable to the conventional platinum counter electrode (8%). Therefore, the low cost and high performance aGNP based counter electrode is a promising alternative to conventional Pt counter electrode in DSSCs.

  12. Design of an extended range long counter using super Monte Carlo simulation

    International Nuclear Information System (INIS)

    Mazunga, Mohamed; Li, Taosheng; Li, Yanan; Hong, Bing; Wang, Yongfeng; Ji, Xiang

    2017-01-01

    We have designed an extended range neutron long counter on the basis of work optimized using SuperMC code. The problem of the existing traditional long counters is that their response function falls rapidly above 5 MeV. We proposed a new designed by adding two layers of converter material inside the polyethylene moderator. The relatively low density chromium and high density lead metals convert high energy neutron by (n, xn) spallation reaction. This produces more neutrons of lower energies, which have higher probability of being detected by thermal 3 He-counter. The response function at lower neutron energies was improved by inserting small polyethylene cylinder in front of 3 He counter. In this design we achieved to extent the flat response function of the long counter from few keV up to 150 MeV. The total fluctuation of response curve is less than ±9% over the entire energy range. The designed long counter is suitable to be used as neutron monitor for monitoring neutron fluence at high-energy neutron source. (authors)

  13. Countering 21st Century Threats

    DEFF Research Database (Denmark)

    Scharling Pedersen, Peter; Pillai, Chad M.; Hun, Lee Jae

    2015-01-01

    ), Counter-Terrorism (CT), and Security and Stability Operations (SSO). • Establishing a construct that allows a strategic Whole-of-Government capacity for operations coordinated by joint interagency task forces. • Continue to developing the Global SOF network. • Increased intelligence sharing in areas...

  14. 78 FR 57623 - TRICARE Over-the-Counter Drug Demonstration Project

    Science.gov (United States)

    2013-09-19

    ... B One-Step (levonorgestrel) emergency contraceptive as an over-the-counter product ``for all women...-Counter Plan B One-Step Emergency Contraceptive (levonorgestrel). (2) OTC availability of Plan B One-Step Emergency Contraceptive (levonorgestrel) through the demonstration project will be at retail dispensing...

  15. Replacement between conformity and counter-conformity in consumption decisions.

    Science.gov (United States)

    Chou, Ting-Jui; Chang, En-Chung; Dai, Qi; Wong, Veronica

    2013-02-01

    This study assessed, in a Chinese context, how self-esteem interacts with perceived similarity and uniqueness to yield cognitive dissonance, and whether the dissonance leads to self-reported conformity or counter-conformity behavior. Participants were 408 respondents from 4 major Chinese cities (M age = 33.0 yr., SD = 4.3; 48% men). Self-perceptions of uniqueness, similarity, cognitive dissonance, self-esteem and need to behave in conformity or counter-conformity were measured. A theoretical model was assessed in four situations, relating the ratings of self-esteem and perceived similarity/uniqueness to the way other people at a wedding were dressed, and the resultant cognitive dissonance and conformity/ counter-conformity behavior. Regardless of high or low self-esteem, all participants reported cognitive dissonance when they were told that they were dressed extremely similarly to or extremely differently from the other people attending the wedding. However, the conforming/counter-conforming strategies used by participants to resolve the cognitive dissonance differed. When encountering dissonance induced by the perceived extreme uniqueness of dress, participants with low self-esteem tended to say they would dress next time so as to conform with the way others were dressed, while those with high self-esteem indicated they would continue their counter-conformity in attire. When encountering dissonance induced by the perceived extreme similarity to others, both those with high and low self-esteem tended to say they would dress in an unorthodox manner to surprise other people in the future.

  16. La “Merced de Dios” y los “duelos y quebrantos”. Calas en algunos enunciados metafóricos y comparaciones en el Quijote

    Directory of Open Access Journals (Sweden)

    María José Rodilla

    2015-06-01

    Full Text Available El Quijote es un rico acervo de enunciados metafóricos, verdaderos tesoros de sabiduría que nos acercan a la época áurea, nos aportan el significado de costumbres perdidas o aluden a alguna circunstancia histórica. Muchos de ellos perviven en la actualidad porque se han convertido en frases proverbiales, cargadas del saber ancestral tan elogiado por los erasmistas y que el mismo Cervantes derramaba en su obra en forma de refranes caídos de la boca de Sancho. Se verán algunos campos semánticos en que podemos clasificar estos enunciados metafóricos y algunas expresiones comparativas: la gastronomía, los animales, referencias espaciales y temporales, metáforas eufemísticas y burlescas. Lo que se pretende, en suma, es hacer algunas calas en una selección de metáforas y comparaciones en el Quijote, con el objetivo no sólo de agruparlas y categorizarlas sino para razonar sobre ellas y, en la medida de lo posible, documentarlas, buscando sus orígenes y significados, y las funciones que ejercen en el texto: describir personajes, compararlos con animales, lograr la comicidad de una situación, desinflar un discurso, visualizar y concretizar imágenes.

  17. Analysis of Thermal Stability of Different Counter on 28nm FPGA

    DEFF Research Database (Denmark)

    Gupta, Daizy; Yadav, Amit; Hussain, Dil muhammed Akbar

    2016-01-01

    In this paper we are presenting the power analysis for thermal awareness of different counters. The technique we are using to do the analysis is based on 28 nm FPGA tech-nique. In this work during implementation on FPGA, we are going to analyze thermal stability of different counters in temperatu...... range of 10oC, 30oC, 60oC, 90oC, 120oC. There is 90.36% reduction in leakage power of divide by 2 counter when we scale down the temperature from 120oC to 10oC and 49.61% reduction in leakage power of LFSR up counter when we scale down the temperature from 120oC to 10oC....

  18. Forensic Speaker Recognition Law Enforcement and Counter-Terrorism

    CERN Document Server

    Patil, Hemant

    2012-01-01

    Forensic Speaker Recognition: Law Enforcement and Counter-Terrorism is an anthology of the research findings of 35 speaker recognition experts from around the world. The volume provides a multidimensional view of the complex science involved in determining whether a suspect’s voice truly matches forensic speech samples, collected by law enforcement and counter-terrorism agencies, that are associated with the commission of a terrorist act or other crimes. While addressing such topics as the challenges of forensic case work, handling speech signal degradation, analyzing features of speaker recognition to optimize voice verification system performance, and designing voice applications that meet the practical needs of law enforcement and counter-terrorism agencies, this material all sounds a common theme: how the rigors of forensic utility are demanding new levels of excellence in all aspects of speaker recognition. The contributors are among the most eminent scientists in speech engineering and signal process...

  19. Ionic magnetic fluids in polar solvents with tuned counter-ions

    Energy Technology Data Exchange (ETDEWEB)

    Lopes Filomeno, C. [Sorbonne Universités, UPMC Univ Paris 06, CNRS, Lab. PHENIX, Paris (France); Grupo de Fluidos Complexos Inst. de Quimica, Univ. de Brasília, Brasília (DF) (Brazil); Kouyaté, M. [Sorbonne Universités, UPMC Univ Paris 06, CNRS, Lab. PHENIX, Paris (France); Cousin, F. [Lab. Léon Brillouin – CE-Saclay, Gif-sur-Yvette (France); Demouchy, G. [Sorbonne Universités, UPMC Univ Paris 06, CNRS, Lab. PHENIX, Paris (France); Dpt de physique, Univ. de Cergy Pontoise, Cergy-Pontoise (France); Dubois, E.; Michot, L.; Mériguet, G. [Sorbonne Universités, UPMC Univ Paris 06, CNRS, Lab. PHENIX, Paris (France); Perzynski, R., E-mail: regine.perzynski@upmc.fr [Sorbonne Universités, UPMC Univ Paris 06, CNRS, Lab. PHENIX, Paris (France); Peyre, V.; Sirieix-Plénet, J. [Sorbonne Universités, UPMC Univ Paris 06, CNRS, Lab. PHENIX, Paris (France); Tourinho, F.A. [Grupo de Fluidos Complexos Inst. de Quimica, Univ. de Brasília, Brasília (DF) (Brazil)

    2017-06-01

    The aim of the present study is to propose a new reproducible method for preparing colloidal dispersions of electrostatically charged nanoparticles (NPs) in polar solvents with different kinds of counter-ions. Maghemite NPs are here dispersed in solvents of different dielectric constant, namely water, dimethylsulfoxide (DMSO) and an ionic liquid, ethylammonium nitrate (EAN). If the existence of a NP superficial charge happens to be necessary for the colloidal stability of the dispersions in these three solvents, the standard DLVO theory cannot be used any more to describe the colloidal stability in EAN. The structure of the dispersions and the strength of the interparticle repulsion are investigated by small angle X-ray scattering measurements, in association with Ludwig–Soret coefficient determinations. Specificities, associated to the nature of the counter-ions are identified in this work on the colloidal stability, on the interparticle repulsion and on the Ludwig–Soret coefficient. - Highlights: • A controlled synthesis of ionic magnetic fluids in three polar solvents is proposed. • Colloidal repulsion in the magnetic fluids depends on the counter-ion nature. • Soret coefficient of citrate-coated maghemite nanoparticles is probed in water-pH7. • Thermophilicity of nanoparticles depends on the nature of their counter-ions. • Nanoparticles dressed with same counter-ions have solvent-dependent thermoproperties.

  20. Construction techniques and operation principles of Geiger-Mueller counters using external cathode (Mazetype)

    International Nuclear Information System (INIS)

    Sevegnani, F.X.

    1988-01-01

    The construction techniques for external cathode (Maze) and internal cathode Geiger-Muller counters are described, showing the operation principles and the used material nature. More than 200 counter types were evaluated analysing their characteristics. The influence of several types of guard-rings was studied, for optimizing counter operation conditions. Plateaus of the order of 700 V with slope of 0,3%/100 V for the net counting rate, and 1400 V with a slope of 0,8/100 V for total counts using total pressure of 10 cmHg, were obtained. A counter for β detection, using blown glass window in one of the edges of the cylinder was constructed. Counters of long life using materials such as, mica, adhesive glues, etc., were obtained. The results shown that the best counter operation occurs when it is empty in a vacuum of 10 -5 mmHg. (M.C.K.) [pt

  1. Development of a honeycomb gas proportional counter array for ...

    Indian Academy of Sciences (India)

    channels, (e) the technology should be amenable to modular design with a minimum of dead space .... contents) of all the affected cells in a cluster. ... the Department of Science and Technology of the Government of India and the CERN PPE.

  2. Large Area X-Ray Proportional Counter (LAXPC) Instrument on ...

    Indian Academy of Sciences (India)

    P. C. Agrawal

    2017-06-19

    Jun 19, 2017 ... high time resolution X-ray observations in 3–80 keV energy band with moderate energy ... able to detect low-and high-frequency QPOs (up ... black hole binaries will provide a tool to probe .... cessed for pulse height analysis.

  3. Beam test of Cherenkov counter prototype for ZDF setup

    International Nuclear Information System (INIS)

    Kacharava, A.K.; Macharashvili, G.G.; Nioradze, M.S.; Komarov, V.I.; Sopov, V.S.; Chernyshev, V.P.

    1995-01-01

    We describe a Cherenkov counter of total internal reflection for particle separation in the momentum range where all types of particles radiate Cherenkov light. The Cherenkov counter prototype with the lucite radiator was tested on the secondary beam of the ITEP (Moscow) accelerator. Dependence of the photomultiplier pulse height on the particle entrance angle was clearly observed. 4 refs., 4 figs

  4. Analogical proportions: another logical view

    Science.gov (United States)

    Prade, Henri; Richard, Gilles

    This paper investigates the logical formalization of a restricted form of analogical reasoning based on analogical proportions, i.e. statements of the form a is to b as c is to d. Starting from a naive set theoretic interpretation, we highlight the existence of two noticeable companion proportions: one states that a is to b the converse of what c is to d (reverse analogy), while the other called paralogical proportion expresses that what a and b have in common, c and d have it also. We identify the characteristic postulates of the three types of proportions and examine their consequences from an abstract viewpoint. We further study the properties of the set theoretic interpretation and of the Boolean logic interpretation, and we provide another light on the understanding of the role of permutations in the modeling of the three types of proportions. Finally, we address the use of these proportions as a basis for inference in a propositional setting, and relate it to more general schemes of analogical reasoning. The differences between analogy, reverse-analogy, and paralogy is still emphasized in a three-valued setting, which is also briefly presented.

  5. A high-efficiency neutron coincidence counter for small samples

    International Nuclear Information System (INIS)

    Miller, M.C.; Menlove, H.O.; Russo, P.A.

    1991-01-01

    The inventory sample coincidence counter (INVS) has been modified to enhance its performance. The new design is suitable for use with a glove box sample-well (in-line application) as well as for use in the standard at-line mode. The counter has been redesigned to count more efficiently and be less sensitive to variations in sample position. These factors lead to a higher degree of precision and accuracy in a given counting period and allow for the practical use of the INVS counter with gamma-ray isotopics to obtain a plutonium assay independent of operator declarations and time-consuming chemicals analysis. A calculation study was performed using the Los Alamos transport code MCNP to optimize the design parameters. 5 refs., 7 figs., 8 tabs

  6. On the Performance of Counter-Based Broadcast Scheme for Mobile ...

    African Journals Online (AJOL)

    Despite its simplicity, it can result in high redundant retransmission, contention and collision, a phenomenon collectively referred to as the broadcast storm problem. Counter-based broadcast scheme has been proposed to mitigate this inherent problem and it relies on counter threshold value for rebroadcast decision. Thus ...

  7. A phenomenological SMA model for combined axial–torsional proportional/non-proportional loading conditions

    International Nuclear Information System (INIS)

    Bodaghi, M.; Damanpack, A.R.; Aghdam, M.M.; Shakeri, M.

    2013-01-01

    In this paper, a simple and robust phenomenological model for shape memory alloys (SMAs) is proposed to simulate main features of SMAs under uniaxial as well as biaxial combined axial–torsional proportional/non-proportional loadings. The constitutive model for polycrystalline SMAs is developed within the framework of continuum thermodynamics of irreversible processes. The model nominates the volume fractions of self-accommodated and oriented martensite as scalar internal variables and the preferred direction of oriented martensitic variants as directional internal variable. An algorithm is introduced to develop explicit relationships for the thermo-mechanical behavior of SMAs under uniaxial and biaxial combined axial–torsional proportional/non-proportional loading conditions and also thermal loading. It is shown that the model is able to simulate main aspects of SMAs including self-accommodation, martensitic transformation, orientation and reorientation of martensite, shape memory effect, ferro-elasticity and pseudo-elasticity. A description of the time-discrete counterpart of the proposed SMA model is presented. Experimental results of uniaxial tension and biaxial combined tension–torsion non-proportional tests are simulated and a good qualitative correlation between numerical and experimental responses is achieved. Due to simplicity and accuracy, the model is expected to be used in the future studies dealing with the analysis of SMA devices in which two stress components including one normal and one shear stress are dominant

  8. Losing the Plot: Narrative, Counter-Narrative and Violent Extremism

    Directory of Open Access Journals (Sweden)

    Andrew Glazzard

    2017-05-01

    Full Text Available Counter-terrorist practitioners and policy makers appear to be very interested in narrative. They often describe the worldview of violent Islamist groups and movements as the ‘jihadi narrative’, while their efforts to confront terrorist propaganda are usually labelled as ‘counter-narrative’ or ‘alternative narrative’. However, while the counter-narrative approach has gained widespread acceptance in governments, think-tanks and civil society organisations, it is built on very shaky theoretical and empirical foundations. Some valuable theoretical contributions to the study of violent extremist narrative have been made by psychologists in particular, but there is one discipline which is conspicuous by its absence from the field: literary studies. This paper makes a case for the value of studying violent extremist narratives as narratives in the literary sense. By employing the tools and techniques of literary criticism, violent extremist communication can be revealed as not only potentially persuasive, but also creative and aesthetically appealing: terrorists inspire their followers, they don’t merely persuade them. Understanding the creative sources of this inspiration is vital if counter-narrative is to succeed in presenting an alternative to the propaganda of violent extremist groups.

  9. Alternative modes for optical trapping and manipulation using counter-propagating shaped beams

    International Nuclear Information System (INIS)

    Palima, D; Tauro, S; Glückstad, J; Lindballe, T B; Kristensen, M V; Stapelfeldt, H; Keiding, S R

    2011-01-01

    Counter-propagating beams have enabled the first stable three-dimensional optical trapping of microparticles and this procedure has been enhanced and developed over the years to achieve independent and interactive manipulation of multiple particles. In this work, we analyse counter-propagating shaped-beam traps that depart from the conventional geometry based on symmetric, coaxial counter-propagating beams. We show that projecting shaped beams with separation distances previously considered axially unstable can, in fact, enhance the axial and transverse trapping stiffnesses. We also show that deviating from using perfectly counter-propagating beams to use oblique beams can improve the axial stability of the traps and improve the axial trapping stiffness. These alternative geometries can be particularly useful for handling larger particles. These results hint at a rich potential for light shaping for optical trapping and manipulation using patterned counter-propagating beams, which still remains to be fully tapped

  10. Which future for nuclear counter-proliferation?

    International Nuclear Information System (INIS)

    Duval, M.

    2010-01-01

    Dealing with the case of nuclear weapons possessed by nuclear states (but not eventually by terrorists), the author first identifies the constants of counter-proliferation: it is linked to interest conflicts between those who try to preserve their monopoly and those who try to acquire a new weapon either because of a threat or for reasons of regional prestige, the evolution from use to deterrence, the appearance of new actors after the USA and Russia, the role of nuclear tactical weapons, and the future of Russian weapons and know-how. He presents the international counter-proliferation context: the Non Proliferation Treaty (NPT), the IAEA and its controls, the Nuclear Supplier Group (NSG), the nuclear-free zones, the Comprehensive Test Ban Treaty (CTBT), the Missile Technology Control Regime (MTCR). He describes how and why proliferation occurs: uranium enrichment and plutonium technology, political reasons in different parts of the world. Then, he gives an overview of the proliferation status by commenting the cases of Israel, Iraq, India, Pakistan, North Korea, and Iran. He discusses the future of proliferation (involved countries, existence of a nuclear black market) and of counter-proliferation as far as Middle-East and North Korea are concerned. He tries finally to anticipate the consequences for nuclear deterrence strategy, and more particularly for Europe and France

  11. 300-MHz optical discriminator-counter

    International Nuclear Information System (INIS)

    Turko, B.; Lo, C.C.

    1981-07-01

    The prediction of future CO 2 content in the atmosphere is not completely credible because the oceanographers and terrestrial ecologists do not agree on the global CO 2 balance. Very precise measurements of O 2 /N 2 ratio using Raman scattering over a few years' period could provide important information and lead to the explanation of the disparity in the atmospheric CO 2 balance. An optical discriminator-counter has been developed to count closely spaced optical events in the few photon level. Simulated optical events as close as 2.5 ns apart had been positively detected by using selected photomultipliers and optimized discriminators. Testing of the optical discriminator-counter was done by using an electrical pulse pair spaced 3 ns apart and also by a similar optical pulse pair generated by fast light-emitting diode. The photomultiplier is capable of counting an average single photoelectron pulse frequency of 50 MHz and has a sensitive detecting area of 50 mm in diameter. The discriminator performance is discussed

  12. Suppression and utilization of spurious pulse occurence in organic GM-counters

    International Nuclear Information System (INIS)

    Narita, Y.; Igarashi, R.; Akagami, H.; Ozawa, Y.

    1979-01-01

    The authors have made a study of suppression and utilization of spurious pulse occurrence in organic GM-counters. Almost all spurious pulses in the organic GM-counter are the delayed pulses which occur being dependent upon the radiation intensity. The occurrence rate of the delayed pulses against the radiation intensity is affected by the intensity of the electric field in the vicinity of the cathode of the GM-counter. The occurrence of the delayed pulses can be suppressed when the electric field in the vicinity of the cathode is kept at high value. On the contrary, the occurrence of the delayed pulses can be utilized for the dosimetry of the pulsed radiation by means of increasing the space of the weak electric field in the GM-counter. (Auth.)

  13. Using Counter-Stories to Challenge Stock Stories about Traveller Families

    Science.gov (United States)

    D'Arcy, Kate

    2017-01-01

    Critical Race Theory (CRT) is formed from a series of different methodological tools to expose and address racism and discrimination. Counter-stories are one of these tools. This article considers the potential of counter-stories as a methodological, theoretical and practical tool to analyse existing educational inequalities for Traveller…

  14. Direct measurement of radioactive carbon in Vietnamese vodkas by Liquid Scintillation Counter

    International Nuclear Information System (INIS)

    Hattori, Takamitsu

    2014-01-01

    From the view point of applying to laboratory exercise of radioactivity measurement by a Liquid Scintillation Counter (LSC), Vietnamese vodkas have specific features as measurement samples, for example, they are colorless, have high ethanol content, and only very few organic materials are included. Investigation was made to make sure that the Vietnamese vodkas are appropriate or not as a measurement sample for the LSC exercise. Direct measurements of 14 C without any chemical pre-treatment were made on both radioactive concentrations and specific activities of three kinds of Vietnamese vodka and also pure ethanol reagent. The LSC measurements reveal that estimated 14 C concentration is proportional to ethanol content in samples and that specific activity of 14 C shows good agreement among the Vietnamese vodkas and pure ethanol, as well as the reference value of 0.25 Bq/g of Carbon. Thus the conclusion is derived that the Vietnamese vodkas can be applied with high accuracy to the LSC exercise as measurement samples. (author)

  15. Counter-Leadership Targeting and Conflict Termination

    National Research Council Canada - National Science Library

    Taylor, Bradly

    1999-01-01

    .... Can the leader be found? And, is it legal and ethical to attack the leader? Analysis rarely has been conducted to determine whether the targeted organization is vulnerable to Counter Leadership Targeting (CLT...

  16. An acoustical bubble counter for superheated drop detectors

    International Nuclear Information System (INIS)

    Taylor, C.; Montvila, D.; Flynn, D.; Brennan, C.; D'Errico, F.

    2006-01-01

    A new bubble counter has been developed based on the well-established approach of detecting vaporization events acoustically in superheated drop detectors (SDDs). This counter is called the Framework Scientific ABC 1260, and it represents a major improvement over prior versions of this technology. By utilizing advanced acoustic pattern recognition software, the bubble formation event can be differentiated from ambient background noise, as well as from other acoustic signatures. Additional structural design enhancements include a relocation of the electronic components to the bottom of the device; thus allowing for greater stability, easier access to vial SDDs without exposure to system electronics. Upgrades in the electronics permit an increase in the speed of bubble detection by almost 50%, compared with earlier versions of the counters. By positioning the vial on top of the device, temperature and sound insulation can be accommodated for extreme environments. Lead shells can also be utilized for an enhanced response to high-energy neutrons. (authors)

  17. An acoustical bubble counter for superheated drop detectors.

    Science.gov (United States)

    Taylor, Chris; Montvila, Darius; Flynn, David; Brennan, Christopher; d'Errico, Francesco

    2006-01-01

    A new bubble counter has been developed based on the well-established approach of detecting vaporization events acoustically in superheated drop detectors (SDDs). This counter is called the Framework Scientific ABC 1260, and it represents a major improvement over prior versions of this technology. By utilizing advanced acoustic pattern recognition software, the bubble formation event can be differentiated from ambient background noise, as well as from other acoustic signatures. Additional structural design enhancements include a relocation of the electronic components to the bottom of the device; thus allowing for greater stability, easier access to vial SDDs without exposure to system electronics. Upgrades in the electronics permit an increase in the speed of bubble detection by almost 50%, compared with earlier versions of the counters. By positioning the vial on top of the device, temperature and sound insulation can be accommodated for extreme environments. Lead shells can also be utilized for an enhanced response to high-energy neutrons.

  18. Counter radicalization development assistance

    OpenAIRE

    van Hippel, Karin

    2006-01-01

    The paper reviews current research and practice and recommends strategies for development agencies working in the Arab and Muslim world. It builds on the basic assumption that the realization of the Millennium Development Goals will be vital to reduce support for terrorism in the long term. Within this overall framework, emphasis is placed on particular programs that could be specifically applied to counter radicalization.

  19. Silica aerogel Cherenkov counter for the KEK B-factory experiment

    CERN Document Server

    Sumiyoshi, T; Enomoto, R; Iijima, T; Suda, R; Leonidopoulos, C; Marlow, D R; Prebys, E; Kawabata, R; Kawai, H; Ooba, T; Nanao, M; Suzuki, K; Ogawa, S; Murakami, A; Khan, M H R

    1999-01-01

    Low-refractive-index silica aerogel is a convenient radiator for threshold-type Cherenkov counters, which are used for particle identification in high-energy physics experiments. For the BELLE detector at the KEK B-Factory we have produced about 2 m sup 3 of hydrophobic silica aerogels of n=1.01-1.03 using a new production method. The particle identification capability of the aerogel Cherenkov counters was tested and 3 sigma pion/proton separation has been achieved at 3.5 GeV/c. Radiation hardness of the aerogels was confirmed up to 9.8 Mrad. The Aerogel Cherenkov counter system (ACC) was successfully installed in the BELLE just before this conference.

  20. Hardware enabled performance counters with support for operating system context switching

    Science.gov (United States)

    Salapura, Valentina; Wisniewski, Robert W.

    2015-06-30

    A device for supporting hardware enabled performance counters with support for context switching include a plurality of performance counters operable to collect information associated with one or more computer system related activities, a first register operable to store a memory address, a second register operable to store a mode indication, and a state machine operable to read the second register and cause the plurality of performance counters to copy the information to memory area indicated by the memory address based on the mode indication.

  1. Counter-Stereotypes and Images: An Exploratory Research and Some Questions

    Science.gov (United States)

    Morin-Messabel, Christine; Ferrière, Séverine; Martinez, Frederic; Devif, Julie; Reeb, Laurence

    2017-01-01

    The dynamics of the construction and perpetuation of gender stereotypes are classic research subjects in social psychology and in the field of educational guidelines in France. The most recent government decree aims to counter stereotypes in schools, by exposing pupils to counter-stereotypes. This study examines the effects of activating…

  2. Development of failure-detecting device for γ radioimmunoassay counter

    International Nuclear Information System (INIS)

    Shao Xianzhi; Zhang Bingfeng

    1997-01-01

    A failures-detecting device based on single chip microcomputer technique for detecting of failures of γ radioimmunoassay counter is developed. The device can output signals of variable amplitude and frequency similar to the pulse of γ particle for shooting problem parts of γ counter's detecting system. By automatically comparing the shapes and amplitudes of the two signals to and from an amplifier unit, the device can distinguish if the amplifier unit works normally. The differential-input amplifier circuit gives 0.1% accuracy for the measurement of the stability of high voltage. The pulse widen circuit of this device allows for middle speed A/D detecting of periodical low-frequency pulse waves of micro-second width. This device is used specifically for the maintaining and failure-detecting of γ radioimmunoassay counter

  3. Wind tunnel tests of stratospheric airship counter rotating propellers

    Directory of Open Access Journals (Sweden)

    Yaxi Chen

    2015-01-01

    Full Text Available Aerodynamic performance of the high-altitude propeller, especially the counter rotation effects, is experimentally studied. Influences of different configurations on a stratospheric airship, included 2-blade counter-rotating propeller (CRP, dual 2-blade single rotation propellers (SRPs and 4-blade SRP, are also indicated. This research indicates that the effect of counter rotation can greatly improve the efficiency. It shows that the CRP configuration results in a higher efficiency than the dual 2-blade SRPs configuration or 4-blade SRP configuration under the same advance ratio, and the CRP configuration also gains the highest efficiency whether under the situation of providing the same trust or absorbing the same power. It concludes that, for a stratospheric airship, the CRP configuration is better than the multiple SRPs configuration or a multi-blade SRP one.

  4. Interactive hypermedia training manual for spent-fuel bundle counters

    International Nuclear Information System (INIS)

    Basso, R.A.

    1990-07-01

    Spent-fuel bundle counters, developed by the Canadian Safeguards Support Program for the International Atomic Energy Agency, provide a secure and independent means of counting the number of irradiated fuel bundles discharged into the fuel storage bays at CANDU nuclear power stations. Paper manuals have been traditionally used to familiarize IAEA inspectors with the operation, maintenance and extensive reporting capabilities of the bundle counters. To further assist inspectors, an interactive training manual has been developed on an Apple Macintosh computer using hypermedia software. The manual uses interactive animation and sound, in conjunction with the traditional text and graphics, to simulate the underlying operation and logic of the bundle counters. This paper presents the key features of the interactive manual and highlights the advantages of this new technology for training

  5. Analytical Solution for the Anisotropic Rabi Model: Effects of Counter-Rotating Terms

    Science.gov (United States)

    Zhang, Guofeng; Zhu, Hanjie

    2015-03-01

    The anisotropic Rabi model, which was proposed recently, differs from the original Rabi model: the rotating and counter-rotating terms are governed by two different coupling constants. This feature allows us to vary the counter-rotating interaction independently and explore the effects of it on some quantum properties. In this paper, we eliminate the counter-rotating terms approximately and obtain the analytical energy spectrums and wavefunctions. These analytical results agree well with the numerical calculations in a wide range of the parameters including the ultrastrong coupling regime. In the weak counter-rotating coupling limit we find out that the counter-rotating terms can be considered as the shifts to the parameters of the Jaynes-Cummings model. This modification shows the validness of the rotating-wave approximation on the assumption of near-resonance and relatively weak coupling. Moreover, the analytical expressions of several physics quantities are also derived, and the results show the break-down of the U(1)-symmetry and the deviation from the Jaynes-Cummings model.

  6. Application of a background-compensated Geiger-Mueller counter to a survey meter

    International Nuclear Information System (INIS)

    Mori, C.; Kumanomido, H.; Watanabe, T.

    1984-01-01

    A background-compensated Geiger-Mueller counter was used as a probe for a GM survey meter to obtain a net count rate of β-rays from a radioactive source in a quick survey. Although a background counting ratio between the two parts in the counter, front and rear, varied somewhat depending on the incident direction of background γ-rays, it was possible to compensate the background counts by subtracting a part of the rear counts, which were background counts, from the front counts, which contained β-ray counts and background counts. Undesirable small pulses generated during the recovering time after a full Geiger discharge were eliminated by an anticoincidence gating method. The survey meter with this counter and a differential ratemeter is useful for obtaining a net count rate of β-rays emitted from a surface radioactive-contamination or from a source being put near the window of the counter with nearly the same accuracy in half the measuring time as compared with conventional GM counters. (orig.)

  7. Test of long scintillating counter prototypes for CDF-II

    International Nuclear Information System (INIS)

    Budagov, Yu.; Chirikov-Zorin, I.; Pukhov, O.; Incagli, M.; Leone, S.; Menzione, A.; Pauletta, G.; Tokar, S.

    2000-01-01

    New type long (up to 3 m) scintillating counter prototypes, developed for CDF-II, have been tested. The shift-spectrum fiber ribbons were used for light collection, and modern ultra compact photomultipliers R5600 were used for light detection. The efficiency for m.i.p. was excellent for all prototypes. The light yield from the far end of the counters was found to be more than 20 photoelectrons

  8. Physical properties of the TOF (time of flight) scintillation counters of DELPHI

    International Nuclear Information System (INIS)

    Benlloch, J.M.; Castillo, M.V.; Ferrer, A.; Fuster, J.; Higon, E.; Llopis, A.; Salt, J.; Sanchez, E.; Sanchis, E.; Silvestre, E.; Cuevas, J.

    1990-01-01

    In this paper we report the physical properties of the time of flight (TOF) scintillator counters used for the DELPHI Experiment at CERN. We discuss the different choices studied for the wrapping of the counters in order to obtain best efficiencies for light transmission. A very good agreement of the performances of the counters has been found with the results of an original Monte Carlo program. The main characteristics of the TOF counters of DELPHI are: an effective light attenuation length of 135 cm, effective light speed of 15.91 cm/ns, a time resolution of 1.2 ns, and an efficiency for detection of minimum ionizing particles of 99.9%. (orig.)

  9. Using Delphi to realize the function of the γ-immuno counter

    International Nuclear Information System (INIS)

    Qi Na; Chu Yan; He Wenhua

    2005-01-01

    This paper introduces the concept of Radioimmunoassay and the background of the γ-immuno counter, summarizes the feature of the Delphi and discusses the superiority of using language of Delphi to realize the function of γ-immuno counter. (authors)

  10. Multicultural Young Adult Literature as a Form of Counter-Storytelling

    Science.gov (United States)

    Hughes-Hassell, Sandra

    2013-01-01

    Counter-storytelling is defined by critical race theory scholars as a method of telling the stories of those people whose experiences are not often told, including people of color, the poor, and members of the LGBTQ community. This article discusses multicultural young adult literature as a form of counter-storytelling, with an emphasis on how…

  11. A large multi-cell threshold gas Cerenkov counter

    International Nuclear Information System (INIS)

    Declais, Y.; Aubert, J.J.; Bassompierre, G.; Payre, P.; Thenard, J.M.; Urban, L.

    1980-08-01

    A large multi-cell threshold gas Cerenkov counter consisting of 78 cells has been built for use in a high energy muon scattering experiment at CERN (European Muon Collaboration). It is used with neon, nitrogen or a mixture of those two gases, allowing the pion threshold to be varied between 6 and 20 GeV/c. The sensitive region of the counter has a length of 4.0 m and entrance and exit windows of 1.1 x 2.4 m 2 and 2.4 x 5.0 m 2 , respectively

  12. Real-time aerosol photometer and optical particle counter comparison

    International Nuclear Information System (INIS)

    Santi, E.; Belosi, F.; Santachiara, G.; Prodi, F.; Berico, M.

    2010-01-01

    The paper presents the results of a comparison exercise among real-time aerosol samplers, based on different light scattering techniques. The comparison was carried out near to the ISAC institute in a box positioned inside the CNR research area in Bologna. Two nephelometers (Dust Trak from TSI, and Air Genius from Unitec) and an optical particle counter (ENVIRO-check from Grimm) were used for P M1 and P M10 fraction assessment. In the case of the optical particle counter, the particle number concentration in each size bin was also used. In parallel, two manual sampling lines were employed for reference (gravimetric) measurements. The results highlight different factor scales for the dust monitors, in comparison with gravimetric assessment, underlining the importance of a user calibration of such monitors as a function of the specific aerosol sampled. Moreover, the relative fluctuations of the hourly P M 10 and P M1 concentrations, against daily average concentrations, were studied in order to compare the ability of each sampler to follow changes in the aerosol size distribution. It was found that the photometers and optical particle counter revealed different behaviours. In the latter, a small increase in the particle concentration number in the coarse fraction gave a relatively high increase in the mass concentration that was not measured by the photometers. The explanation could be the relatively slight influence of a small particle number variation on the total scattered light for the photometers, unlike the case of the optical particle counter, where each particle contributes to the mass concentration. This aspect merits future research in order to better understand optical particle counter output used in P Mx monitoring activities.

  13. Analytical Solution for the Anisotropic Rabi Model: Effects of Counter-Rotating Terms

    OpenAIRE

    Zhang, Guofeng; Zhu, Hanjie

    2015-01-01

    The anisotropic Rabi model, which was proposed recently, differs from the original Rabi model: the rotating and counter-rotating terms are governed by two different coupling constants. This feature allows us to vary the counter-rotating interaction independently and explore the effects of it on some quantum properties. In this paper, we eliminate the counter-rotating terms approximately and obtain the analytical energy spectrums and wavefunctions. These analytical results agree well with the ...

  14. A Survey of Teenagers' Attitudes Toward Moving Oral Contraceptives Over the Counter.

    Science.gov (United States)

    Manski, Ruth; Kottke, Melissa

    2015-09-01

    Evidence suggests that over-the-counter access to oral contraceptives may help expand use among adult women. Teenagers may particularly benefit from this approach, as they experience disproportionately high rates of unintended pregnancy and face unique challenges accessing contraceptives. However, limited research has explored teenagers' attitudes toward over-the-counter access. In 2014, a sample of 348 females aged 14-17, recruited via Facebook advertisements, participated in an online survey assessing teenagers' attitudes toward over-the-counter access and their understanding of how to use oral contraceptives after reading a prototype over-the-counter product label. Differences by participants' characteristics were assessed in bivariate analyses (Pearson chi-square and Fisher's exact tests for categorical measures, and independent t tests and one-way analyses of variance for continuous measures). Seventy-three percent of participants supported over-the-counter access, and 61% reported that they would likely use oral contraceptives available through this approach. Few subgroup differences were found. Notably, sexually experienced participants were significantly more likely than others both to support this approach (85% vs. 63%) and to be interested in obtaining oral contraceptives this way (77% vs. 48%). Participants understood an average of 7.1 of eight key concepts that the prototype product label was intended to convey; no significant differences were found among subgroups. Over-the-counter access may be a promising approach for providing oral contraceptives to teenagers. Additional research is needed to evaluate whether teenagers can screen themselves for contraindications to oral contraceptive use and correctly use oral contraceptives obtained over the counter. Copyright © 2015 by the Guttmacher Institute.

  15. Advanced computer-controlled automatic alpha-beta air sample counter

    International Nuclear Information System (INIS)

    Howell, W.P.; Bruinekool, D.J.; Stapleton, E.E.

    1983-01-01

    An improved computer controlled automatic alpha-beta air sample counter was developed, based upon an earlier automatic air sample counter design. The system consists of an automatic sample changer, an electronic counting system utilizing a large silicon diode detector, a small desk-type microcomputer, a high speed matrix printer, and the necessary data interfaces. The system is operated by commands from the keyboard and programs stored on magnetic tape cassettes. The programs provide for background counting, Chi 2 test, radon subtraction, and sample counting for sample periods of one day to one week. Output data are printed by the matrix printer on standard multifold paper. The data output includes gross beta, gross alpha, and plutonium results. Data are automatically corrected for background, counter efficiency, and in the gross alpha and plutonium channels, for the presence of radon

  16. Emergent information technologies and enabling policies for counter-terrorism

    CERN Document Server

    Popp, R

    2006-01-01

    Explores both counter-terrorism and enabling policy dimensions of emerging information technologies in national security After the September 11th attacks, "connecting the dots" has become the watchword for using information and intelligence to protect the United States from future terrorist attacks. Advanced and emerging information technologies offer key assets in confronting a secretive, asymmetric, and networked enemy. Yet, in a free and open society, policies must ensure that these powerful technologies are used responsibly, and that privacy and civil liberties remain protected. Emergent Information Technologies and Enabling Policies for Counter-Terrorism provides a unique, integrated treatment of cutting-edge counter-terrorism technologies and their corresponding policy options. Featuring contributions from nationally recognized authorities and experts, this book brings together a diverse knowledge base for those charged with protecting our nation from terrorist attacks while preserving our civil liberti...

  17. Gold leaf counter electrodes for dye-sensitized solar cells

    Science.gov (United States)

    Shimada, Kazuhiro; Toyoda, Takeshi

    2018-03-01

    In this study, a gold leaf 100 nm thin film is used as the counter electrode in dye-sensitized solar cells. The traditional method of hammering gold foil to obtain a thin gold leaf, which requires only small amounts of gold, was employed. The gold leaf was then attached to the substrate using an adhesive to produce the gold electrode. The proposed approach for fabricating counter electrodes is demonstrated to be facile and cost-effective, as opposed to existing techniques. Compared with electrodes prepared with gold foil and sputtered gold, the gold leaf counter electrode demonstrates higher catalytic activity with a cobalt-complex electrolyte and higher cell efficiency. The origin of the improved performance was investigated by surface morphology examination (scanning electron microscopy), various electrochemical analyses (cyclic voltammetry, linear sweep voltammetry, and electrochemical impedance spectroscopy), and crystalline analysis (X-ray diffractometry).

  18. The Principle of Proportionality

    DEFF Research Database (Denmark)

    Bennedsen, Morten; Meisner Nielsen, Kasper

    2005-01-01

    Recent policy initiatives within the harmonization of European company laws have promoted a so-called "principle of proportionality" through proposals that regulate mechanisms opposing a proportional distribution of ownership and control. We scrutinize the foundation for these initiatives...... in relationship to the process of harmonization of the European capital markets.JEL classifications: G30, G32, G34 and G38Keywords: Ownership Structure, Dual Class Shares, Pyramids, EU companylaws....

  19. Tobacco counter-advertising: a review of the literature and a conceptual model for understanding effects.

    Science.gov (United States)

    Agostinelli, Gina; Grube, Joel W

    2003-01-01

    The tobacco counter-advertising literature is reviewed as it relates to basic process questions concerning what makes counter-advertisements effective. Limitations in addressing (a) counter-advertisement content and the psychological mediators targeted, (b) counter-advertisement style and the affective reactions targeted, (c) prior smoking experience, and (d) other audience factors are enumerated. A theoretical model based on alcohol advertising research is presented to address those limitations. The model addresses the practical research question of predicting when tobacco counter-advertising will work by examining the independent influence of each of these enumerated factors, as well as how these factors operate in concert, qualifying each other. The model also addresses the process question of explaining how counter-advertising works by identifying affective and cognitive processes as mediators. By understanding the processes that underlie the qualified findings, one can better advise the designers of tobacco counter-advertisements how to be more effective.

  20. PERUMUSAN STRATEGI PEMASARAN FRY COUNTER DENGAN PENDEKATAN MODEL AIDA

    OpenAIRE

    Andi Oktoriyana; Ujang Sumarwan; Hartoyo Hartoyo

    2014-01-01

    This research examined factors which are mentioned in various literatures that have influence on AIDA models to buy fry counter which are attention, interest, and desire. The model also influenced by perceived attributes, personal characteristics, and external factors. Furthermore, the analysis result become a basic for formulating the marketing strategy of fry counter as an innovative product. Analysis was carried out using Structural Equation Modeling. The data for this study were collected...

  1. Using DMA for copying performance counter data to memory

    Science.gov (United States)

    Gara, Alan; Salapura, Valentina; Wisniewski, Robert W

    2013-12-31

    A device for copying performance counter data includes hardware path that connects a direct memory access (DMA) unit to a plurality of hardware performance counters and a memory device. Software prepares an injection packet for the DMA unit to perform copying, while the software can perform other tasks. In one aspect, the software that prepares the injection packet runs on a processing core other than the core that gathers the hardware performance data.

  2. A Fear Management Approach to Counter-Terrorism

    Directory of Open Access Journals (Sweden)

    Tinka Veldhuis

    2012-02-01

    Full Text Available Spreading fear is the essence of terrorism. Terrorists exploit fear by terrorising the target audience into concessions. Understanding how feelings of fear influence the way people feel, think and act is therefore an important starting point to explore how individuals and societies can learn how to cope with fear of terrorism. In this Policy Brief, Research Fellows Prof. Dr. Edwin Bakker and Dr. Tinka Veldhuis explore the dynamics of fear in response to terrorism, and emphasise the importance of integrating initiatives to manage fear of terrorism and reduce its negative consequences into overarching counter-terrorism strategies. It argues that societies can benefit greatly from promoting resilience and a fear management approach to counter-terrorism.

  3. Flooding in counter-current two-phase flow

    International Nuclear Information System (INIS)

    Ragland, W.A.; Ganic, E.N.

    1982-01-01

    Flooding is a phenomenon which is best described as the transition from counter-current to co-current flow. Early notice was taken of this phenomenon in the chemical engineering industry. Flooding also plays an important role in the field of two-phase heat transfer since it is a limit for many systems involving counter-current flow. Practical applications of flooding limited processes include wickless thermosyphons and the emergency core cooling system (ECCS) of pressurized water nuclear reactors. The phenomenon of flooding also is involved in the behavior of nuclear reactor core materials during severe accident conditions where flooding is one of the mechanisms governing the motion of the molten fuel pin cladding

  4. Flooding in counter-current two-phase flow

    Energy Technology Data Exchange (ETDEWEB)

    Ragland, W.A.; Ganic, E.N.

    1982-01-01

    Flooding is a phenomenon which is best described as the transition from counter-current to co-current flow. Early notice was taken of this phenomenon in the chemical engineering industry. Flooding also plays an important role in the field of two-phase heat transfer since it is a limit for many systems involving counter-current flow. Practical applications of flooding limited processes include wickless thermosyphons and the emergency core cooling system (ECCS) of pressurized water nuclear reactors. The phenomenon of flooding also is involved in the behavior of nuclear reactor core materials during severe accident conditions where flooding is one of the mechanisms governing the motion of the molten fuel pin cladding.

  5. Visualization study of helium-air counter flow through a small opening

    International Nuclear Information System (INIS)

    Fumizawa, Motoo

    2007-01-01

    Buoyancy-driven counter flows of helium-air were investigated through horizontal and inclined small openings. Counter flows may occur following a window opening as ventilation, fire in the room as well as a pipe rupture accident in a high temperature gas-cooled nuclear reactor. The experiment has carried out by a test chamber filled with helium and flow was visualized by the smoke wire method. The flow behavior has recorded by a high-speed camera with a computer system. The image of the flow was transferred to the digital data, thus the flow velocity was measured by PTV software. The mass fraction in the test chamber was measured by electronic balance. The detected data was arranged by the densimetric Floude number of the counter flow rate that derived from the dimensional analysis. The method of mass increment was developed and applied to measure the counter flow rate. By removing the cover plate placed on the top of the opening, the counter flow initiated. Air enters the test chamber and the mass of the gas mixture in the test chamber increased. The volumetric counter flow rate was evaluated from the mass increment data. In the case of inclination openings, the results of both methods were compared. The inclination angle for maximum densimetric Floude number decreased with increasing length-to-diameter ratio of the opening. For a horizontal opening, the results from the method of mass increment agreed with those obtained by other authors for a water-brine system. (author)

  6. Countering North Korean Special Purpose Forces

    National Research Council Canada - National Science Library

    Krause, Troy

    1999-01-01

    As United States and Republic of Korea forces stand to defend against a DPRK attack, one of the most formidable tasks is how to counter a second front in the Joint Rear Security Area of the Republic of Korea...

  7. Fundamentals of gas counters

    International Nuclear Information System (INIS)

    Bateman, J.E.

    1994-01-01

    The operation of gas counters used for detecting radiation is explained in terms of the four fundamental physical processes which govern their operation. These are 1) conversion of neutral radiation into charged particles, 2) ionization of the host gas by a fast charge particle 3) transport of the gas ions to the electrodes and 4) amplification of the electrons in a region of enhanced electric field. Practical implications of these are illustrated. (UK)

  8. The n,{gamma} discrimination in recoil-proton proportional counters. Application to the measurement of fast neutron spectra; Discrimination n,{gamma} dans les compteurs proportionnels a protons de recul. Application a la mesure des spectres de neutrons rapides

    Energy Technology Data Exchange (ETDEWEB)

    Jeandidier, C [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1969-07-01

    A description is given of a spectrometry chain working in the energy range of a few keV to 1 MeV, and designed for measurement of fast neutron spectra. It consists of detectors, recoil proton proportional counters built especially for this work by R. COMTE (DEG/SER) and which make it possible to cover the energy range and also associated electronic equipment. A brief description is first given of the physical processes involved: (n,p) collisions in the gas, influence of {gamma} radiation; the method of discrimination is then presented. It is based on the difference in the rise-times of the pulses. In the experiments described here the use of a bi-parametric system made it possible to employ the most simple discrimination device, based on the fact that the high frequency gamma pulse components are, at a given energy, weaker than those of the neutron pulses. Results are given of measurements carried out on the Van der Graaff (mono-energetic neutrons for testing the linearity of the chain and the resolving power of the counters), and of those made in a sub-critical system Hug at Cadarache. (author) [French] On decrit une chaine de spectrometrie travaillant dans le domaine d'energie de quelques keV a 1 MeV destinee a la mesure des spectres de neutrons rapides. Elle comprend les detecteurs, compteurs proportionnels a protons de recul, realises specialement pour cette etude par M. R. COMTE (DEG/SER), permettant de couvrir la gamme d'energie et l'electronique associee. Apres un rappel des processus physiques mis en jeu: chocs (n,p) dans les gaz, influence des rayonnements {gamma}, on expose la methode de discrimination utilisee. Celle-ci est basee sur la difference des temps de montee des impulsions. Au cours des experiences rapportees ici, la mise en oeuvre d'un ensemble bi-parametrique a permis d'utiliser le dispositif de discrimination le plus simple, base sur la remarque que les composantes a haute frequence des impulsions {gamma} sont, a energie egale, plus faibles

  9. The n,{gamma} discrimination in recoil-proton proportional counters. Application to the measurement of fast neutron spectra; Discrimination n,{gamma} dans les compteurs proportionnels a protons de recul. Application a la mesure des spectres de neutrons rapides

    Energy Technology Data Exchange (ETDEWEB)

    Jeandidier, C. [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1969-07-01

    A description is given of a spectrometry chain working in the energy range of a few keV to 1 MeV, and designed for measurement of fast neutron spectra. It consists of detectors, recoil proton proportional counters built especially for this work by R. COMTE (DEG/SER) and which make it possible to cover the energy range and also associated electronic equipment. A brief description is first given of the physical processes involved: (n,p) collisions in the gas, influence of {gamma} radiation; the method of discrimination is then presented. It is based on the difference in the rise-times of the pulses. In the experiments described here the use of a bi-parametric system made it possible to employ the most simple discrimination device, based on the fact that the high frequency gamma pulse components are, at a given energy, weaker than those of the neutron pulses. Results are given of measurements carried out on the Van der Graaff (mono-energetic neutrons for testing the linearity of the chain and the resolving power of the counters), and of those made in a sub-critical system Hug at Cadarache. (author) [French] On decrit une chaine de spectrometrie travaillant dans le domaine d'energie de quelques keV a 1 MeV destinee a la mesure des spectres de neutrons rapides. Elle comprend les detecteurs, compteurs proportionnels a protons de recul, realises specialement pour cette etude par M. R. COMTE (DEG/SER), permettant de couvrir la gamme d'energie et l'electronique associee. Apres un rappel des processus physiques mis en jeu: chocs (n,p) dans les gaz, influence des rayonnements {gamma}, on expose la methode de discrimination utilisee. Celle-ci est basee sur la difference des temps de montee des impulsions. Au cours des experiences rapportees ici, la mise en oeuvre d'un ensemble bi-parametrique a permis d'utiliser le dispositif de discrimination le plus simple, base sur la remarque que les composantes a haute frequence des impulsions {gamma} sont, a

  10. VOICES AGAINST EXTREMISM: A CASE STUDY OF A COMMUNITY-BASED CVE COUNTER-NARRATIVE CAMPAIGN

    Directory of Open Access Journals (Sweden)

    Logan Macnair

    2017-03-01

    Full Text Available This article presents a case study of the recently conceived and ongoing counter-extremism campaign, Voices Against Extremism, a campaign designed and implemented by university students from Vancouver, Canada. Through a multifaceted approach that includes extensive use of social media, academic research, and grassroots community activities and involvement, Voices Against Extremism operates under the mission statement of countering and preventing violent extremism and radicalization through the humanization of minority groups and through the education and engagement of the silent majority. This article examines the effectiveness of this campaign as a proactive counter-radicalization strategy by outlining its specific components and activities. Based on the results of this campaign, suggestions are then offered regarding specific counter-extremism and counter-radicalizations policies that may be adopted by law enforcement, policymakers – or any other organizations concerned with countering and preventing radicalization and violent extremism – with a specific focus on the potential benefits of proactive and long-term social and community engagement.

  11. CCM-R: Secure Counter Synchronization for IoT Wireless Link

    DEFF Research Database (Denmark)

    Roy, Upal; Yin, Jiachen; Andersen, Birger

    2016-01-01

    In this paper we propose and evaluate a new version of the CCM mode of operation, CCM-R, which isan extended and alternate version of the original CBC-MAC with Counter Mode(CCM) that was created to address the problem of counter synchronization. While CCM is considered secure when used/implemente...... it suitable for low-power wireless IoT devices....

  12. Radiation thickness gauge using beta particle sensitivity controlled open air corona streamer counter

    International Nuclear Information System (INIS)

    Fouad, L.; El-Hazek, S.; El-Araby, S.

    1999-01-01

    Beta particles have been used extensively in radio gauging applications when measurements of foil thicknesses are desired. Using beta particle open air corona streamer counter (point-grid-plane) as a thickness gauge is presented. This gauge consists of two similar counters with two similar Sr-90 beta sources. One counter-source combination is called standard unit, and the other counter-source combination is called measuring unit in which the required foil thickness can be measured by inserting it between the source and the counter. The signals from the counters are amplified with the same gain factor and the net difference between their responses is measured using specially designed electronic circuit. By this way any change that takes place in the operating medium (variation of parameters of open air i.e. temperature, humidity...etc) can similarly affect the two units, the errors in the measurements caused by them are cancelled, and the only response is due to the measured foil thickness. A theoretical model is suggested to explain and analyze the overall response of the gauge system and calculate the calibration thickness gauge constant. All theoretical findings are confirmed by experiments

  13. Development of a lithium fluoride zinc sulfide based neutron multiplicity counter

    Science.gov (United States)

    Cowles, Christian; Behling, Spencer; Baldez, Phoenix; Folsom, Micah; Kouzes, Richard; Kukharev, Vladislav; Lintereur, Azaree; Robinson, Sean; Siciliano, Edward; Stave, Sean; Valdez, Patrick

    2018-04-01

    The feasibility of a full-scale lithium fluoride zinc sulfide (LiF/ZnS) based neutron multiplicity counter has been demonstrated. The counter was constructed of modular neutron detecting stacks that each contain five sheets of LiF/ZnS interleaved between six sheets of wavelength shifting plastic with a photomultiplier tube on each end. Twelve such detector stacks were placed around a sample chamber in a square arrangement with lithiated high-density polyethylene blocks in the corners to reflect high-energy neutrons and capture low-energy neutrons. The final system design was optimized via modeling and small-scale test. Measuring neutrons from a 252Cf source, the counter achieved a 36% neutron detection efficiency (ɛ) and an 11 . 7 μs neutron die-away time (τ) for a doubles figure-of-merit (ɛ2 / τ) of 109. This is the highest doubles figure-of-merit measured to-date for a 3He-free neutron multiplicity counter.

  14. Paid counter-advertising: proven strategy to combat tobacco use and promotion.

    Science.gov (United States)

    Blum, A

    1994-01-01

    This article discusses the effectiveness of paid counter-advertising in combating tobacco use and promotion, the impact of the Fairness Doctrine, which mandated anticigarette television advertisements in the late 1960s, and reasons why the media today are reluctant to run antismoking advertisements. Although counter-advertisements can work very well, they should be image-based, rather than fact-based. Currently, tobacco companies promote a positive image of cigarette smoking and brand awareness. Most antismoking ads, however, tend to focus on the tobacco itself and its adverse effects on the smoker, rather than combating the images the cigarette ads promote. Urging counter-advertising to focus on the product, rather than to try to produce guilt in smokers, this article provides examples of paid counter-advertising strategies employed by Doctors Ought to Care to illustrate an image-based approach. Overall, the antismoking movement must guard against complacency and measure its success according to tobacco companies' declining revenues, rather than the number of public service advertisements in the media.

  15. Counter-current acid leaching process for copper azole treated wood waste.

    Science.gov (United States)

    Janin, Amélie; Riche, Pauline; Blais, Jean-François; Mercier, Guy; Cooper, Paul; Morris, Paul

    2012-09-01

    This study explores the performance of a counter-current leaching process (CCLP) for copper extraction from copper azole treated wood waste for recycling of wood and copper. The leaching process uses three acid leaching steps with 0.1 M H2SO4 at 75degrees C and 15% slurry density followed by three rinses with water. Copper is recovered from the leachate using electrodeposition at 5 amperes (A) for 75 min. Ten counter-current remediation cycles were completed achieving > or = 94% copper extraction from the wood during the 10 cycles; 80-90% of the copper was recovered from the extract solution by electrodeposition. The counter-current leaching process reduced acid consumption by 86% and effluent discharge volume was 12 times lower compared with the same process without use of counter-current leaching. However, the reuse of leachates from one leaching step to another released dissolved organic carbon and caused its build-up in the early cycles.

  16. Evaluating Middle Years Students' Proportional Reasoning

    Science.gov (United States)

    Hilton, Annette; Dole, Shelley; Hilton, Geoff; Goos, Merrilyn; O'Brien, Mia

    2012-01-01

    Proportional reasoning is a key aspect of numeracy that is not always developed naturally by students. Understanding the types of proportional reasoning that students apply to different problem types is a useful first step to identifying ways to support teachers and students to develop proportional reasoning in the classroom. This paper describes…

  17. The Eros of Counter Education

    Science.gov (United States)

    Luzon, Pinhas

    2016-01-01

    Erotic Counter Education (ECE) is the educational position of the late Ilan Gur-Ze'ev. In ECE Gur-Ze'ev combines two opposing positions in the philosophy of education, one teleological and anti-utopian, the other teleological and utopian. In light of this unique combination, I ask what mediates between these two poles and suggest that the answer…

  18. The cognitive costs of the counter-stereotypic: gender, emotion, and social presence.

    Science.gov (United States)

    McCarty, Megan K; Kelly, Janice R; Williams, Kipling D

    2014-01-01

    We explored the concurrent and subsequent cognitive consequences of the experience of gender counter-stereotypic emotions. Participants experiencing gender counter-stereotypic emotions were expected to display less emotional expression and demonstrate poorer cognitive performance when in the public condition than when in the private condition. Seventy-one women and 66 men completed an anger- or sadness-inducing task privately or publicly. Participants completed two cognitive tasks: one during and one after the emotion-induction task. Participants exhibited poorer performance during and following gender counter-stereotypic emotions only in the public condition. Direct evidence for greater suppression of gender counter-stereotypic emotions in the public conditions was not obtained. These results suggest that the same public emotional events may be differentially cognitively depleting depending on one's gender, potentially contributing to the perpetuation of stereotypes.

  19. Can counter-stereotypes boost flexible thinking?

    NARCIS (Netherlands)

    Goclowska, M.A.; Crisp, R.J.; Labuschagne, K.

    2013-01-01

    To reduce prejudice psychologists design interventions requiring people to think of counter-stereotypes (i.e., people who defy stereotypic expectations—a strong woman, a Black President). Grounded in the idea that stereotypes constrain the ability to think flexibly, we propose that thinking of

  20. Optical fusions and proportional syntheses

    Science.gov (United States)

    Albert-Vanel, Michel

    2002-06-01

    A tragic error is being made in the literature concerning matters of color when dealing with optical fusions. They are still considered to be of additive nature, whereas experience shows us somewhat different results. The goal of this presentation is to show that fusions are, in fact, of 'proportional' nature, tending to be additive or subtractive, depending on each individual case. Using the pointillist paintings done in the manner of Seurat, or the spinning discs experiment could highlight this intermediate sector of the proportional. So, let us try to examine more closely what occurs in fact, by reviewing additive, subtractive and proportional syntheses.

  1. The Tax Evasion in Ukraine: Causes and Methods of Countering

    Directory of Open Access Journals (Sweden)

    Parfentii Liudmyla A.

    2018-03-01

    Full Text Available The essence of the concept of tax evasion is researched; reasons of occurrence and development of this phenomenon are analyzed; proposals on the main directions of prevention and countering tax evasion have been developed. Analyzing, systematizing and generalizing the scientific works of many scholars, it was found that there is no unified approach to interpretation of the essence of this phenomenon in the context of legality and awareness of relevant actions in the scientific literature. As a result of the research the factors of tax evasion with the allocation of moral, political, economic, technical, and legal reasons have been systematized. The preconditions of tax evasion in Ukraine are analyzed, the most common schemes are indicated, resulting from which the budget of Ukraine suffers the greatest losses. Methods of countering tax offenses have been researched and necessity of development and implementation of measures on prevention and countering tax evasion at the State level has been substantiated. Prospects for further researches in this direction are studying of foreign experience of countering tax evasion and detailed analyzing of the tax minimization schemes prevalent in Ukraine with the purpose of identifying ways of elimination of possibility of their use.

  2. Analysis of counter flow of corona wind for heat transfer enhancement

    Science.gov (United States)

    Shin, Dong Ho; Baek, Soo Hong; Ko, Han Seo

    2018-03-01

    A heat sink for cooling devices using the counter flow of a corona wind was developed in this study. Detailed information about the numerical investigations of forced convection using the corona wind was presented. The fins of the heat sink using the counter flow of a corona wind were also investigated. The corona wind generator with a wire-to-plate electrode arrangement was used for generating the counter flow to the fin. The compact and simple geometric characteristics of the corona wind generator facilitate the application of the heat sink using the counter flow, demonstrating the heat sink is effective for cooling electronic devices. Parametric studies were performed to analyze the effect of the counter flow on the fins. Also, the velocity and temperature were measured experimentally for the test mock-up of the heat sink with the corona wind generator to verify the numerical results. From a numerical study, the type of fin and its optimal height, length, and pitch were suggested for various heat fluxes. In addition, the correlations to calculate the mass of the developed heat sink and its cooling performance in terms of the heat transfer coefficient were derived. Finally, the cooling efficiencies corresponding to the mass, applied power, total size, and noise of the devices were compared with the existing commercial central processing unit (CPU) cooling devices with rotor fans. As a result, it was confirmed that the heat sink using the counter flow of the corona wind showed appropriate efficiencies for cooling electronic devices, and is a suitable replacement for the existing cooling device for high power electronics.

  3. Scintillation counter based radiation dosimeter

    International Nuclear Information System (INIS)

    Shin, Jeong Hyun

    2009-02-01

    The average human exposure per year is about 240mrem which is come from Radon and human body and terrestrial and cosmic radiation and man-made source. Specially radiation exposure through air from environmental radiation sources is 80mrem/yr(= 0.01mR/hr) which come from Terrestrial and cosmic radiation. Radiation dose is defined as energy deposit/mass. There are two major methods to detect radiation. First method is the energy integration using Air equivalent material like GM counter wall material. Second method is the spectrum to dose conversion method using NaI(Tl), HPGe. These two methods are using generally to detect radiation. But these methods are expensive. So we need new radiation detection method. The research purpose is the development of economical environmental radiation dosimeter. This system consists of Plastic/Inorganic scintillator and Si photo-diode based detector and counting based circuitry. So count rate(cps) can be convert to air exposure rate(R/hr). There are three major advantages in this system. First advantages is no high voltage power supply like GM counter. Second advantage is simple electronics. Simple electronics system can be achieved by Air-equivalent scintillation detector with Al filter for the same detection efficiency vs E curve. From former two advantages, we can know the most important advantages of the this system. Third advantage is economical system. The price of typical GM counter is about $1000. But the price of our system is below $100 because of plastic scintillator and simple electronics. The role of scintillation material is emitting scintillation which is the flash of light produced in certain materials when they absorb ionizing radiation. Plastic scintillator is organic scintillator which is kind of hydrocarbons. The special point are cheap price, large size production(∼ton), moderate light output, fast light emission(ns). And the role of Al filter is equalizing counting efficiency of air and scintillator for

  4. Programmable automatic alpha--beta air sample counter

    International Nuclear Information System (INIS)

    Howell, W.P.

    1978-01-01

    A programmable automatic alpha-beta air sample counter was developed for routine sample counting by operational health physics personnel. The system is composed of an automatic sample changer utilizing a large silicon diode detector, an electronic counting system with energy analysis capability, an automatic data acquisition controller, an interface module, and a teletypewriter with paper tape punch and paper tape reader. The system is operated through the teletypewriter keyboard and the paper tape reader, which are used to instruct the automatic data acquisition controller. Paper tape programs are provided for background counting, Chi 2 test, and sample counting. Output data are printed by the teletypewriter on standard continuous roll or multifold paper. Data are automatically corrected for background and counter efficiency

  5. Calibration of the neutron scintillation counter threshold

    International Nuclear Information System (INIS)

    Noga, V.I.; Ranyuk, Yu.N.; Telegin, Yu.N.

    1978-01-01

    A method for calibrating the threshold of a neutron counter in the form of a 10x10x40 cm plastic scintillator is described. The method is based on the evaluation of the Compton boundary of γ-spectrum from the discrimination curve of counter loading. The results of calibration using 60 Co and 24 Na γ-sources are given. In order to eValuate the Compton edge rapidly, linear extrapolation of the linear part of the discrimination curve towards its intersection with the X axis is recommended. Special measurements have shown that the calibration results do not practically depend on the distance between the cathode of a photomultiplier and the place where collimated γ-radiation of the calibration source reaches the scintillator

  6. Standardization of calibration method of whole-body counter. 1. Calibration by using anthropometric phantoms

    International Nuclear Information System (INIS)

    Ishikawa, Tetsuo; Matsumoto, Masaki; Uchiyama, Masafumi; Kobayashi, Sadayoshi; Mizushita, Seiichi.

    1995-01-01

    To standardize the calibration methods of whole-body counters, three anthropometric phantoms were manufactured based on dozens of Japanese average value of body size data. Using these phantoms, the calibrations of some whole-body counters were carried out and the comparison of counting efficiency between anthropometric phantoms and block phantoms, which used to be used for the calibration of whole-body counters generally, was implemented. Five whole-body counters, one scanning system, two stationary systems and two chair systems, were used for this study. The following results were derived: As an example, in NIRS scanning system, the counting efficiency of anthropometric phantom of 162cm height was 12.7% greater than that of block phantom of the same height. This means 137 Cs body burdens in adult men used to be estimated with the excess of about 10%. Body burdens tended to be estimated excessively in adult because the difference of counting efficiency between anthropometric phantom and block phantom increases with increase of height. To standardize body burden data measured with various whole-body counters, the calibration of each whole-body counter should be conducted using anthropometric phantoms and phantoms which used to be used for the calibration of that whole-body counter. (author)

  7. Evaluation of in-plant neutron coincidence counters for the measurement of molten salt extraction residues

    International Nuclear Information System (INIS)

    Langner, D.G.; Russo, P.A.; Wachter, J.R.

    1993-01-01

    Americium is extracted from plutonium by a molten salt extraction (MSE) process. The residual americium-laden salts are a significant waste stream in this pyrochemical purification process. Rapid assay of MSE residues is desirable to minimize the exposure of personnel to these often high-level emissions. However, the quantitative assay of plutonium in MSE residues is difficult. Variable, unknown (a,n) rates and variable emitted-neutron energy spectra preclude the use of standard neutron coincidence counting techniques with old-generation neutron coincidence counters. Gamma-ray assay methods have not been successful with some residues because of random lumps of plutonium metal. In this paper, we present measurements of MSE residues with two state-of-the-art neutron coincidence counters at the Los Alamos Plutonium Processing Facility: an in-line counter built for the assay of bulk waste material and the pyrochemical multiplicity counter that underwent test and evaluation at that facility. Both of these counters were designed to minimize the effects on measurements of variations in the sample geometry and variable energy spectra of emitted neutrons. These results are compared to measurements made with an HLNCII and with a 20-yr-old in-line well counter. The latter two counters are not optimized in ft sense. We conclude that the newer counters provide significantly improved assay results. The pyrochemical multiplicity counter operated in the conventional coincidence mode provided the best assays overall

  8. The influence of the counter-rotating terms on the superradiant emission

    International Nuclear Information System (INIS)

    Seke, J.

    1984-01-01

    Agarwal's master equation for the Dicke model is modified by including the counter-rotating terms. By solving the corresponding equations of motion for the atomic expectation values, it is shown that the counter-rotating terms play an important role in the time evolution of the population inversion and radiation rate

  9. Is counter-terrorism policy evidence-based? What works, what harms, and what is unknown.

    Science.gov (United States)

    Lum, Cynthia; Kennedy, Leslie W; Sherley, Alison

    2008-02-01

    Is counter-terrorism policy evidence-based? What works, what harms, and what is unknown. One of the central concerns surrounding counter-terrorism interventions today, given the attention and money spent on them, is whether such interventions are effective. To explore this issue, we conducted a general review of terrorism literature as well as a Campbell systematic review on counter-terrorism strategies. In this article, we summarize some of our findings from these works. Overall, we found an almost complete absence of evaluation research on counter-terrorism strategies and conclude that counter-terrorism policy is not evidence-based. The findings of this review emphasise the need for government leaders, policy makers, researchers, and funding agencies to include and insist on evaluations of the effectiveness of these programs in their agendas.

  10. Proportioning of U3O8 powder

    International Nuclear Information System (INIS)

    Cermak, V.; Markvart, M.; Novy, P.; Vanka, M.

    1989-01-01

    The tests are briefly described or proportioning U 3 O 8 powder of a granulometric grain size range of 0-160 μm using a vertical screw, a horizontal dual screw and a vibration dispenser with a view to proportioning very fine U 3 O 8 powder fractions produced in the oxidation of UO 2 fuel pellets. In the tests, the evenness of proportioning was assessed by the percentage value of the proportioning rate spread measured at one-minute intervals at a proportioning rate of 1-3 kg/h. In feeding the U 3 O 3 in a flame fluorator, it is advantageous to monitor the continuity of the powder column being proportioned and to assess it radiometrically by the value of the proportioning rate spread at very short intervals (0.1 s). (author). 10 figs., 1 tab., 12 refs

  11. Timecourse of mirror and counter-mirror effects measured with transcranial magnetic stimulation.

    Science.gov (United States)

    Cavallo, Andrea; Heyes, Cecilia; Becchio, Cristina; Bird, Geoffrey; Catmur, Caroline

    2014-08-01

    The human mirror system has been the subject of much research over the past two decades, but little is known about the timecourse of mirror responses. In addition, it is unclear whether mirror and counter-mirror effects follow the same timecourse. We used single-pulse transcranial magnetic stimulation to investigate the timecourse of mirror and counter-mirror responses in the human brain. Experiment 1 demonstrated that mirror responses can be measured from around 200 ms after observed action onset. Experiment 2 demonstrated significant effects of counter-mirror sensorimotor training at all timepoints at which a mirror response was found in Experiment 1 (i.e. from 200 ms onward), indicating that mirror and counter-mirror responses follow the same timecourse. By suggesting similarly direct routes for mirror and counter-mirror responses, these results support the associative account of mirror neuron origins whereby mirror responses arise as a result of correlated sensorimotor experience during development. More generally, they contribute to theorizing regarding mirror neuron function by providing some constraints on how quickly mirror responses can influence social cognition. © The Author (2013). Published by Oxford University Press. For Permissions, please email: journals.permissions@oup.com.

  12. Counter-Chemical, Biological, Radiological, and Nuclear Operations

    National Research Council Canada - National Science Library

    2007-01-01

    ..., with little or no warning. Success in defending our nation, our military forces, and partners and allies depends on how effectively we apply air, space, and cyberspace power to counter this threat...

  13. Proportional Symbol Mapping in R

    Directory of Open Access Journals (Sweden)

    Susumu Tanimura

    2006-01-01

    Full Text Available Visualization of spatial data on a map aids not only in data exploration but also in communication to impart spatial conception or ideas to others. Although recent carto-graphic functions in R are rapidly becoming richer, proportional symbol mapping, which is one of the common mapping approaches, has not been packaged thus far. Based on the theories of proportional symbol mapping developed in cartography, the authors developed some functions for proportional symbol mapping using R, including mathematical and perceptual scaling. An example of these functions demonstrated the new expressive power and options available in R, particularly for the visualization of conceptual point data.

  14. Impossibility Theorem in Proportional Representation Problem

    International Nuclear Information System (INIS)

    Karpov, Alexander

    2010-01-01

    The study examines general axiomatics of Balinski and Young and analyzes existed proportional representation methods using this approach. The second part of the paper provides new axiomatics based on rational choice models. New system of axioms is applied to study known proportional representation systems. It is shown that there is no proportional representation method satisfying a minimal set of the axioms (monotonicity and neutrality).

  15. E143 experiment. Shower counter calibration

    International Nuclear Information System (INIS)

    Fonvieille, H.; Grenier, P.

    1994-01-01

    The calibration procedure for the shower counters used in the E143 experiment is described. It has been developed during january 1994 in view of being used for the quick analysis. The method is explained and the results obtained on a given run are presented. (author)

  16. Gramscian ‘Counter hegemony’ in Narendra Modi’s New India Perspective

    Directory of Open Access Journals (Sweden)

    Venkat Rao Pulla

    2017-03-01

    Full Text Available The counter hegemony   that Gramsci, (1987:344 talks about is about leaders and their understanding and how well they conceptualise the psychology of the masses. Counter hegemonies have transformative power and Modi continues to prove that. In this special editorial, the author reviews the leadership of Mr Modi in India.

  17. Al Qaeda’s “Single Narrative” and Attempts to Develop Counter-Narratives

    Directory of Open Access Journals (Sweden)

    Alex P. Schmid

    2014-01-01

    Full Text Available In this Research Paper, Research Fellow Dr. Alex Schmid dissects the nature of Al Qaeda’s propaganda strategy by looking how it incorporates in its ideological narrative Islam’s sacred texts and traditions and how it manages to link these to widespread contemporary grievances in the Muslim world. Al Qaeda’s survival is tied to the credibility of its narrative “story” rather than the physical survival of its leadership. The Research Paper discusses mainly American and British efforts to challenge the integrative (hence: “single” narrative of Al Qaeda. Current counter-narratives often fall short of reaching objectives due to a lack of credibility – a result of the gap between official Western declaratory policies and actual policies on the ground. Efforts to sell “hearts and minds” products often floundered on policies that lack legitimacy or stood in stark contrast to professed values like adherence to human rights standards, thereby creating perceptions of double standards and hypocrisy. While Al Qaeda’s policies exhibit similar, and in some areas even greater, discrepancies between what is being said and what is being done, these have not been fully exploited. Following the discussion of governmental efforts to counter Al Qaeda’s narrative, findings and suggestions from academia, think tanks, religious scholars and others trying to counter Al Qaeda’s narrative are presented. While it is generally true that counter-narrative work is still in its infancy, the survey of various proposals and programs makes clear that important building blocks for a more creative effort of countering the ideological attraction of Al Qaeda exist. One of the problems with counter-narratives is their defensive and reactive nature and their focus on packaging messages. This paper emphasises the importance of crafting and spreading an alternative narrative. While counter-narratives have to aim at discrediting the exclusive narrative of Al Qaeda

  18. The effects of gender stereotypic and counter-stereotypic textbook images on science performance.

    Science.gov (United States)

    Good, Jessica J; Woodzicka, Julie A; Wingfield, Lylan C

    2010-01-01

    We investigated the effect of gender stereotypic and counter-stereotypic images on male and female high school students' science comprehension and anxiety. We predicted stereotypic images to induce stereotype threat in females and impair science performance. Counter-stereotypic images were predicted to alleviate threat and enhance female performance. Students read one of three chemistry lessons, each containing the same text, with photograph content varied according to stereotype condition. Participants then completed a comprehension test and anxiety measure. Results indicate that female students had higher comprehension after viewing counter-stereotypic images (female scientists) than after viewing stereotypic images (male scientists). Male students had higher comprehension after viewing stereotypic images than after viewing counter-stereotypic images. Implications for alleviating the gender gap in science achievement are discussed.

  19. Informational and symbolic content of over-the-counter drug advertising on television.

    Science.gov (United States)

    Tsao, J C

    1997-01-01

    The informational and symbolic content of 150 over-the-counter drug commercials on television are empirically analyzed in this study. Results on the informational content suggest that over-the-counter drug ads tend to focus on the concern of what the drug will do for the consumer, rather than on the reasons why the drug should be ingested. Accordingly, advertising strategy is centered on consumer awareness of the product as the primary goal. Educational commitment, however, did not seem to be blended into the promotional efforts for over-the-counter drugs. Findings on the symbolic content of over-the-counter drug ads reveal that drug images have been distorted. Performance of most drugs has been portrayed to be simple resolutions to relieve the symptom. Moreover, a casual attitude toward drug usage is encouraged in the commercials, while time lapse of drug effects is overlooked.

  20. Electromagnetic shower counter

    CERN Multimedia

    CERN PhotoLab

    1974-01-01

    The octogonal block of lead glass is observed by eight photomultiplier tubes. Four or five such counters, arranged in succession, are used on each arm of the bispectrometer in order to detect heavy particles of the same family as those recently observed at Brookhaven and SLAC. They provide a means of identifying electrons. The arrangement of eight lateral photomultiplier tubes offers an efficient means of collecting the photons produced in the showers and determining, with a high resolution, the energy of the incident electrons. The total width at half-height is less than 6.9% for electrons having an energy of 1 GeV.