WorldWideScience

Sample records for promising filtration method

  1. Method of electrostatic filtration

    International Nuclear Information System (INIS)

    Devienne, F.M.

    1975-01-01

    Electrostatic filtration of secondary ions of mass m in a given mass ratio with a primary ion of mass M which has formed the secondary ions by fission is carried out by a method which consists in forming a singly-charged primary ion of the substance having a molecular mass M and extracting the ion at a voltage V 1 with respect to ground. The primary ion crosses a potential barrier V 2 , in producing the dissociation of the ion into at least two fragments of secondary ions and in extracting the fragment ion of mass m at a voltage V 2 . Filtration is carried out in an electrostatic analyzer through which only the ions of energy eV'' are permitted to pass, detecting the ions which have been filtered. The mass m of the ions is such that (M/m) = (V 1 - V 2 )/(V'' - V 2 )

  2. A FILTRATION METHOD AND APPARATUS

    DEFF Research Database (Denmark)

    2003-01-01

    The present invention concerns a method and an apparatus for separating dry matter from liquid, comprising providing an enclosed separation environment capable of being pressure regulated, and in said enclosed separation environment contacting at least one filter with a suspension accumulating dr...

  3. A rigid porous filter and filtration method

    Energy Technology Data Exchange (ETDEWEB)

    Chiang, Ta-Kuan; Straub, Douglas, Straub L.; Dennis, Richard A.

    1998-12-01

    The present invention involves a porous rigid filter comprising a plurality of concentric filtration elements having internal flow passages and forming external flow passages there between. The present invention also involves a pressure vessel containing the filter for the removal of particulate from high pressure particulate containing gases, and further involves a method for using the filter to remove such particulate. The present filter has the advantage of requiring fewer filter elements due to the high surface area- to-volume ratio provided by the filter, requires a reduced pressure vessel size, and exhibits enhanced mechanical design properties, improved cleaning properties, configuration options, modularity and ease of fabrication.

  4. Transform and filtration methods in fluctuation analysis

    International Nuclear Information System (INIS)

    Saxe, R.F.

    1976-01-01

    Digitized fluctuation signals from an ex-core ion-chamber of a PWR were analysed to produce a Power Spectral Density, (PSD), curve by two means: (1) by digital filter techniques and (2) by a Fast Fourier Transform program. For both these methods, the effects of the precision of the input data were investigated and it is shown that reasonably good PSD curves may be obtained using very poor input precision. (author)

  5. Groundwater Quality Improvement by Using Aeration and Filtration Methods

    OpenAIRE

    Nik N. Nik Daud; Nur H. Izehar; B. Yusuf; Thamer A. Mohamed; A. Ahsan

    2013-01-01

    An experiment was conducted using two aeration methods (water-into-air and air-into-water) and followed by filtration processes using manganese greensand material. The properties of groundwater such as pH, dissolved oxygen, turbidity and heavy metal concentration (iron and manganese) will be assessed. The objectives of this study are i) to determine the effective aeration method and ii) to assess the effectiveness of manganese greensand as filter media in removing iron an...

  6. Simple method for the estimation of glomerular filtration rate

    Energy Technology Data Exchange (ETDEWEB)

    Groth, T [Group for Biomedical Informatics, Uppsala Univ. Data Center, Uppsala (Sweden); Tengstroem, B [District General Hospital, Skoevde (Sweden)

    1977-02-01

    A simple method is presented for indirect estimation of the glomerular filtration rate from two venous blood samples, drawn after a single injection of a small dose of (/sup 125/I)sodium iothalamate (10 ..mu..Ci). The method does not require exact dosage, as the first sample, taken after a few minutes (t=5 min) after injection, is used to normilize the value of the second sample, which should be taken in between 2 to 4 h after injection. The glomerular filtration rate, as measured by standard insulin clearance, may then be predicted from the logarithm of the normalized value and linear regression formulas with a standard error of estimate of the order of 1 to 2 ml/min/1.73 m/sup 2/. The slope-intercept method for direct estimation of glomerular filtration rate is also evaluated and found to significantly underestimate standard insulin clearance. The normalized 'single-point' method is concluded to be superior to the slope-intercept method and more sophisticated methods using curve fitting technique, with regard to predictive force and clinical applicability.

  7. Non-filtration method of processing uranium ores

    International Nuclear Information System (INIS)

    Laskorin, B.N.; Vodolazov, L.I.; Tokarev, N.N.; Vyalkov, V.I.; Goldobina, V.A.; Gosudarstvennyj Komitet po Ispol'zovaniyu Atomnoj Ehnergii SSSR, Moscow)

    1977-01-01

    The development of the non-filtration sorption method has lead to procedures of the sorption leaching and the extraction desorption, which have made it possible to intensify the processing of uranium ores and to improve greatly the technical and economic indexes by eliminating the complex method of multiple filtration and re-pulping of cakes. This method makes it possible to involve more poor uranium raw materials, at the same time extracting valuable components such as molybdenum, vanadium, copper, etc. Considerable industrial experience has been acquired in the sorption of dense pulp with a solid-to-liquid phase ratio of 1:1. This has led to a plant production increase of 1.5-3.0 times, an increase of uranium extraction by 5-10%, a two- to- three-fold increase of labour capacity of the main workers, and to a several-fold decrease of reagents, auxiliary materials, electric energy and vapour. This non-filtration method is a continuous process in all its phases thanks to the use of high-yield and high-power equipment for high-density pulps. (author)

  8. Non-filtration method of processing of uranium ores

    International Nuclear Information System (INIS)

    Laskorin, B.N.; Vodolazov, L.I.; Tokarev, N.N.; Vyalkov, V.I.; Goldobina, V.A.; Gosudarstvennyj Komitet po Ispol'zovaniyu Atomnoj Ehnergii SSSR, Moscow)

    1977-01-01

    The development of the filterless sorption method has lead to working out the sorption leaching process and the process of extraction desorption, which has made possible to intensify the process of uranium ore working and to improve greatly the technical economic indexes by liquidating the complex method of multiple filtration and repulping of cakes. This method makes possible to involve more poor uranium raw materials and at the same time to extract valuable components: molybdenum, vanadium, copper, etc. Great industrial experience has been accumulating in sorption of dense pulp with the ratio of solid phase to liquid one equal to 1:1. This has lead to the increase of productivity of working plants by 1,5-3,0 times, the increase of uranium extraction by 5-10%, the increase of labour capacity of main workers by 2-3 times, and to the decrease of reagents expense, auxiliary materials, electric energy and vapour by several times. In fact the developed technology is continuous in all its steps with complete complex automatization of the process with the help of the most simple and available means of regulation and controlling. The process is equipped with high productivity apparatuses of great power with mechanic and pneumatic mixing for high density pulps, and with the columns KDS, KDZS, KNSPR and PIK for the regeneration of saturated sorbent in the counterflow regime. The exploitation of fine-granular hydrophilic ion-exchange resins in hydrophobized state is foreseen [ru

  9. [Rapid prototyping: a very promising method].

    Science.gov (United States)

    Haverman, T M; Karagozoglu, K H; Prins, H-J; Schulten, E A J M; Forouzanfar, T

    2013-03-01

    Rapid prototyping is a method which makes it possible to produce a three-dimensional model based on two-dimensional imaging. Various rapid prototyping methods are available for modelling, such as stereolithography, selective laser sintering, direct laser metal sintering, two-photon polymerization, laminated object manufacturing, three-dimensional printing, three-dimensional plotting, polyjet inkjet technology,fused deposition modelling, vacuum casting and milling. The various methods currently being used in the biomedical sector differ in production, materials and properties of the three-dimensional model which is produced. Rapid prototyping is mainly usedforpreoperative planning, simulation, education, and research into and development of bioengineering possibilities.

  10. An overview of filtration methods that can provide protection from the macrofouling zebra mussel at hydroelectric facilities

    Energy Technology Data Exchange (ETDEWEB)

    Smythe, A.G.; Short, T.M. [Acres International Corp., Amherst, NY (United States)

    1995-12-31

    The non-indigenous freshwater zebra and quagga mussels (Dreissena, spp.) threaten to foul freshwater conduits throughout much of the United States and southern Canada. Initially, many electric facilities within the lower Great Lakes drainage were fouled. More recently, other systems both in and out of the Great Lakes, have been exposed to infested water facilitated by canals and boat traffic and impacted by the mussels. Mussels have clogged conduits and fouled equipment and monitoring sensors in relatively distant regions including the Hudson River, the Mississippi River south to New Orleans, and the Arkansas River into Oklahoma. Chemicals can effectively control the mussels, however, filtration methods promise to be a relatively cost effective, environmentally safe alternative control approach. Information on traditional filtration methods will be presented in this paper along with recent research results for in-line filters.

  11. Method for semi-automated microscopy of filtration-enriched circulating tumor cells.

    Science.gov (United States)

    Pailler, Emma; Oulhen, Marianne; Billiot, Fanny; Galland, Alexandre; Auger, Nathalie; Faugeroux, Vincent; Laplace-Builhé, Corinne; Besse, Benjamin; Loriot, Yohann; Ngo-Camus, Maud; Hemanda, Merouan; Lindsay, Colin R; Soria, Jean-Charles; Vielh, Philippe; Farace, Françoise

    2016-07-14

    Circulating tumor cell (CTC)-filtration methods capture high numbers of CTCs in non-small-cell lung cancer (NSCLC) and metastatic prostate cancer (mPCa) patients, and hold promise as a non-invasive technique for treatment selection and disease monitoring. However filters have drawbacks that make the automation of microscopy challenging. We report the semi-automated microscopy method we developed to analyze filtration-enriched CTCs from NSCLC and mPCa patients. Spiked cell lines in normal blood and CTCs were enriched by ISET (isolation by size of epithelial tumor cells). Fluorescent staining was carried out using epithelial (pan-cytokeratins, EpCAM), mesenchymal (vimentin, N-cadherin), leukocyte (CD45) markers and DAPI. Cytomorphological staining was carried out with Mayer-Hemalun or Diff-Quik. ALK-, ROS1-, ERG-rearrangement were detected by filter-adapted-FISH (FA-FISH). Microscopy was carried out using an Ariol scanner. Two combined assays were developed. The first assay sequentially combined four-color fluorescent staining, scanning, automated selection of CD45(-) cells, cytomorphological staining, then scanning and analysis of CD45(-) cell phenotypical and cytomorphological characteristics. CD45(-) cell selection was based on DAPI and CD45 intensity, and a nuclear area >55 μm(2). The second assay sequentially combined fluorescent staining, automated selection of CD45(-) cells, FISH scanning on CD45(-) cells, then analysis of CD45(-) cell FISH signals. Specific scanning parameters were developed to deal with the uneven surface of filters and CTC characteristics. Thirty z-stacks spaced 0.6 μm apart were defined as the optimal setting, scanning 82 %, 91 %, and 95 % of CTCs in ALK-, ROS1-, and ERG-rearranged patients respectively. A multi-exposure protocol consisting of three separate exposure times for green and red fluorochromes was optimized to analyze the intensity, size and thickness of FISH signals. The semi-automated microscopy method reported here

  12. Method for semi-automated microscopy of filtration-enriched circulating tumor cells

    International Nuclear Information System (INIS)

    Pailler, Emma; Oulhen, Marianne; Billiot, Fanny; Galland, Alexandre; Auger, Nathalie; Faugeroux, Vincent; Laplace-Builhé, Corinne; Besse, Benjamin; Loriot, Yohann; Ngo-Camus, Maud; Hemanda, Merouan; Lindsay, Colin R.; Soria, Jean-Charles; Vielh, Philippe; Farace, Françoise

    2016-01-01

    Circulating tumor cell (CTC)-filtration methods capture high numbers of CTCs in non-small-cell lung cancer (NSCLC) and metastatic prostate cancer (mPCa) patients, and hold promise as a non-invasive technique for treatment selection and disease monitoring. However filters have drawbacks that make the automation of microscopy challenging. We report the semi-automated microscopy method we developed to analyze filtration-enriched CTCs from NSCLC and mPCa patients. Spiked cell lines in normal blood and CTCs were enriched by ISET (isolation by size of epithelial tumor cells). Fluorescent staining was carried out using epithelial (pan-cytokeratins, EpCAM), mesenchymal (vimentin, N-cadherin), leukocyte (CD45) markers and DAPI. Cytomorphological staining was carried out with Mayer-Hemalun or Diff-Quik. ALK-, ROS1-, ERG-rearrangement were detected by filter-adapted-FISH (FA-FISH). Microscopy was carried out using an Ariol scanner. Two combined assays were developed. The first assay sequentially combined four-color fluorescent staining, scanning, automated selection of CD45 − cells, cytomorphological staining, then scanning and analysis of CD45 − cell phenotypical and cytomorphological characteristics. CD45 − cell selection was based on DAPI and CD45 intensity, and a nuclear area >55 μm 2 . The second assay sequentially combined fluorescent staining, automated selection of CD45 − cells, FISH scanning on CD45 − cells, then analysis of CD45 − cell FISH signals. Specific scanning parameters were developed to deal with the uneven surface of filters and CTC characteristics. Thirty z-stacks spaced 0.6 μm apart were defined as the optimal setting, scanning 82 %, 91 %, and 95 % of CTCs in ALK-, ROS1-, and ERG-rearranged patients respectively. A multi-exposure protocol consisting of three separate exposure times for green and red fluorochromes was optimized to analyze the intensity, size and thickness of FISH signals. The semi-automated microscopy method reported here

  13. Measurement of water filtration in skeletal muscle in man by an osmotic transient method

    DEFF Research Database (Denmark)

    Palm, T; Nielsen, S L; Lassen, N A

    1983-01-01

    Water filtration in the human forearm was determined with a new method using a hyperoncotic transient of albumin solution infused into the brachial artery. Baseline dilution of labelled albumin in deep forearm vein plasma in excess of the contribution from arterial blood and from infusate...... was assumed to originate from extravascular water filtered into the blood by the transient. The filtration coefficient (Fc) was determined as the ratio between filtered water and increase in colloid osmotic pressure in the blood samples, and gives the filtrative water permeability in the exchange areas...... muscles, but it is of the same order of magnitude as the capillary filtration coefficient (CFC) determined plethysmographically for the entire forearm by the venous stasis technique....

  14. A FILTRATION METHOD AND APPARATUS INCLUDING A ROLLER WITH PORES

    DEFF Research Database (Denmark)

    2008-01-01

    The present invention offers a method for separating dry matter from a medium. A separation chamber is at least partly defined by a plurality of rollers (2,7) and is capable of being pressure regulated. At least one of the rollers is a pore roller (7) having a surface with pores allowing permeabi...

  15. Development of a promising filtration method for liquid clarification in nuclear facilities

    International Nuclear Information System (INIS)

    Collins, E.D.; Knauer, J.B.; Byrd, L.A.; Ross, R.G.; Savage, H.C.

    1982-01-01

    Conclusions reached are that deep beds of diatomaceous earths are especially attractive for clarification of radioactive solutions, or slurries containing insoluble radioactive material, because the diatomaceous material provides a noncompressible medium that is retentive for a wide variety of particle sizes. Also, the diatomaceous material, because of its inorganic composition, is resistant to degradation by radiation from the retained particulate matter. Its silicious character is especially appropriate for conversion to vitrified or cement-type waste forms. This paper studied the use of diatomaceous earth to filter synthetic TMI-2 water, reprocessing dissolver solutions, and zinc bromide solutions (hot-cell shielding)

  16. A fit method for the determination of inherent filtration with diagnostic x-ray units

    International Nuclear Information System (INIS)

    Meghzifene, K; Nowotny, R; Aiginger, H

    2006-01-01

    A method for the determination of total inherent filtration for clinical x-ray units using attenuation curves was devised. A model for the calculation of x-ray spectra is used to calculate kerma values which are then adjusted to the experimental data in minimizing the sum of the squared relative differences in kerma using a modified simplex fit process. The model considers tube voltage, voltage ripple, anode angle and additional filters. Fit parameters are the thickness of an additional inherent Al filter and a general normalization factor. Nineteen sets of measurements including attenuation data for three tube voltages and five Al-filter settings each were obtained. Relative differences of experimental and calculated kerma using the data for the additional filter thickness are within a range of -7.6% to 6.4%. Quality curves, i.e. the relationship of additional filtration to HVL, are often used to determine filtration but the results show that standard quality curves do not reflect the variety of conditions encountered in practice. To relate the thickness of the additional filter to the condition of the anode surface, the data fits were also made using tungsten as the filter material. These fits gave an identical fit quality compared to aluminium with a tungsten filter thickness of 2.12-8.21 μm which is within the range of the additional absorbing layers determined for rough anodes

  17. Filtration Characterization Method as Tool to Assess Membrane Bioreactor Sludge Filterability—The Delft Experience

    Directory of Open Access Journals (Sweden)

    Maria Lousada-Ferreira

    2014-04-01

    Full Text Available Prevention and removal of fouling is often the most energy intensive process in Membrane Bioreactors (MBRs, responsible for 40% to 50% of the total specific energy consumed in submerged MBRs. In the past decade, methods were developed to quantify and qualify fouling, aiming to support optimization in MBR operation. Therefore, there is a need for an evaluation of the lessons learned and how to proceed. In this article, five different methods for measuring MBR activated sludge filterability and critical flux are described, commented and evaluated. Both parameters characterize the fouling potential in full-scale MBRs. The article focuses on the Delft Filtration Characterization method (DFCm as a convenient tool to characterize sludge properties, namely on data processing, accuracy, reproducibility, reliability, and applicability, defining the boundaries of the DFCm. Significant progress was made concerning fouling measurements in particular by using straight forward approaches focusing on the applicability of the obtained results. Nevertheless, a fouling measurement method is still to be defined which is capable of being unequivocal, concerning the fouling parameters definitions; practical and simple, in terms of set-up and operation; broad and useful, in terms of obtained results. A step forward would be the standardization of the aforementioned method to assess the sludge filtration quality.

  18. Filtration of human EEG recordings from physiological artifacts with empirical mode method

    Science.gov (United States)

    Grubov, Vadim V.; Runnova, Anastasiya E.; Khramova, Marina V.

    2017-03-01

    In the paper we propose the new method for dealing with noise and physiological artifacts in experimental human EEG recordings. The method is based on analysis of EEG signals with empirical mode decomposition (Hilbert-Huang transform). We consider noises and physiological artifacts on EEG as specific oscillatory patterns that cause problems during EEG analysis and can be detected with additional signals recorded simultaneously with EEG (ECG, EMG, EOG, etc.) We introduce the algorithm of the method with following steps: empirical mode decomposition of EEG signal, choosing of empirical modes with artifacts, removing empirical modes with artifacts, reconstruction of the initial EEG signal. We test the method on filtration of experimental human EEG signals from eye-moving artifacts and show high efficiency of the method.

  19. Quantifying Neonatal Sucking Performance: Promise of New Methods.

    Science.gov (United States)

    Capilouto, Gilson J; Cunningham, Tommy J; Mullineaux, David R; Tamilia, Eleonora; Papadelis, Christos; Giannone, Peter J

    2017-04-01

    Neonatal feeding has been traditionally understudied so guidelines and evidence-based support for common feeding practices are limited. A major contributing factor to the paucity of evidence-based practice in this area has been the lack of simple-to-use, low-cost tools for monitoring sucking performance. We describe new methods for quantifying neonatal sucking performance that hold significant clinical and research promise. We present early results from an ongoing study investigating neonatal sucking as a marker of risk for adverse neurodevelopmental outcomes. We include quantitative measures of sucking performance to better understand how movement variability evolves during skill acquisition. Results showed the coefficient of variation of suck duration was significantly different between preterm neonates at high risk for developmental concerns (HRPT) and preterm neonates at low risk for developmental concerns (LRPT). For HRPT, results indicated the coefficient of variation of suck smoothness increased from initial feeding to discharge and remained significantly greater than healthy full-term newborns (FT) at discharge. There was no significant difference in our measures between FT and LRPT at discharge. Our findings highlight the need to include neonatal sucking assessment as part of routine clinical care in order to capture the relative risk of adverse neurodevelopmental outcomes at discharge. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.

  20. Filtration Isolation of Nucleic Acids: A Simple and Rapid DNA Extraction Method.

    Science.gov (United States)

    McFall, Sally M; Neto, Mário F; Reed, Jennifer L; Wagner, Robin L

    2016-08-06

    FINA, filtration isolation of nucleic acids, is a novel extraction method which utilizes vertical filtration via a separation membrane and absorbent pad to extract cellular DNA from whole blood in less than 2 min. The blood specimen is treated with detergent, mixed briefly and applied by pipet to the separation membrane. The lysate wicks into the blotting pad due to capillary action, capturing the genomic DNA on the surface of the separation membrane. The extracted DNA is retained on the membrane during a simple wash step wherein PCR inhibitors are wicked into the absorbent blotting pad. The membrane containing the entrapped DNA is then added to the PCR reaction without further purification. This simple method does not require laboratory equipment and can be easily implemented with inexpensive laboratory supplies. Here we describe a protocol for highly sensitive detection and quantitation of HIV-1 proviral DNA from 100 µl whole blood as a model for early infant diagnosis of HIV that could readily be adapted to other genetic targets.

  1. Aerosol filtration

    International Nuclear Information System (INIS)

    First, M.W.; Gilbert, H.

    1982-01-01

    Significant developments in high-efficiency filtration for nuclear applications are reviewed for the period 1968 to 1980. Topics of special interest include (1) factory (bench) and in-place test methods, (2) new developments in paper and filter unit construction methods, (3) vented containment air cleaning systems for liquid-metal fast breeder reactors and light-water-moderated reactors, and (4) decontamination of off-gases from nuclear waste volume-reduction processes. Standards development has been vigorously pursued during this period, but advances in filtration theory have been few. One of the significant changes likely to occur in the immediate future is adoption of the European style of high-efficiency particulate air filters instead of those which have been in service for the past three decades to obtain the benefits of having almost twice as much filter paper in the same filter cartridge

  2. Aerosol filtration

    International Nuclear Information System (INIS)

    First, M.W.; Gilbert, H.

    1981-01-01

    Significant developments in high efficiency filtration for nuclear applications are reviewed for the period 1968 to 1980. Topics of special interest include factory (bench) and in-place test methods, new developments in paper and filter unit construction methods, vented containment air cleaning systems for LMFBR and light water moderated reactors, and decontamination of offgases from nuclear waste volume reduction processes. It is noted that standards development has been vigorously pursued during this period but that advances in filtration theory have been few. One of the significant changes likely to occur in the immediate future is adoption of the European style of HEPA filters for those that have been in service for the past three decades to obtain the benefits of having almost twice as much filter paper in the same filter cartridge. 71 references

  3. Single- versus multiple-sample method to measure glomerular filtration rate.

    Science.gov (United States)

    Delanaye, Pierre; Flamant, Martin; Dubourg, Laurence; Vidal-Petiot, Emmanuelle; Lemoine, Sandrine; Cavalier, Etienne; Schaeffner, Elke; Ebert, Natalie; Pottel, Hans

    2018-01-08

    There are many different ways to measure glomerular filtration rate (GFR) using various exogenous filtration markers, each having their own strengths and limitations. However, not only the marker, but also the methodology may vary in many ways, including the use of urinary or plasma clearance, and, in the case of plasma clearance, the number of time points used to calculate the area under the concentration-time curve, ranging from only one (Jacobsson method) to eight (or more) blood samples. We collected the results obtained from 5106 plasma clearances (iohexol or 51Cr-ethylenediaminetetraacetic acid (EDTA)) using three to four time points, allowing GFR calculation using the slope-intercept method and the Bröchner-Mortensen correction. For each time point, the Jacobsson formula was applied to obtain the single-sample GFR. We used Bland-Altman plots to determine the accuracy of the Jacobsson method at each time point. The single-sample method showed within 10% concordances with the multiple-sample method of 66.4%, 83.6%, 91.4% and 96.0% at the time points 120, 180, 240 and ≥300 min, respectively. Concordance was poorer at lower GFR levels, and this trend is in parallel with increasing age. Results were similar in males and females. Some discordance was found in the obese subjects. Single-sample GFR is highly concordant with a multiple-sample strategy, except in the low GFR range (<30 mL/min). © The Author 2018. Published by Oxford University Press on behalf of ERA-EDTA. All rights reserved.

  4. Sensitive enumeration of Listeria monocytogenes and other Listeria species in various naturally contaminated matrices using a membrane filtration method.

    Science.gov (United States)

    Barre, Léna; Brasseur, Emilie; Doux, Camille; Lombard, Bertrand; Besse, Nathalie Gnanou

    2015-06-01

    For the enumeration of Listeria monocytogenes (L. monocytogenes) in food, a sensitive enumeration method has been recently developed. This method is based on a membrane filtration of the food suspension followed by transfer of the filter on a selective medium to enumerate L. monocytogenes. An evaluation of this method was performed with several categories of foods naturally contaminated with L. monocytogenes. The results obtained with this technique were compared with those obtained from the modified reference EN ISO 11290-2 method for the enumeration of L. monocytogenes in food, and are found to provide more precise results. In most cases, the filtration method enabled to examine a greater quantity of food thus greatly improving the sensitivity of the enumeration. However, it was hardly applicable to some food categories because of filtration problems and background microbiota interference. Copyright © 2014 Elsevier Ltd. All rights reserved.

  5. Stem Cell Therapy: A Promising Therapeutic Method for Intracerebral Hemorrhage.

    Science.gov (United States)

    Gao, Liansheng; Xu, Weilin; Li, Tao; Chen, Jingyin; Shao, Anwen; Yan, Feng; Chen, Gao

    2018-01-01

    Spontaneous intracerebral hemorrhage (ICH) is one type of the most devastating cerebrovascular diseases worldwide, which causes high morbidity and mortality. However, efficient treatment is still lacking. Stem cell therapy has shown good neuroprotective and neurorestorative effect in ICH and is a promising treatment. In this study, our aim was to review the therapeutic effects, strategies, related mechanisms and safety issues of various types of stem cell for ICH treatment. Numerous studies had demonstrated the therapeutic effects of diverse stem cell types in ICH. The potential mechanisms include tissue repair and replacement, neurotrophy, promotion of neurogenesis and angiogenesis, anti-apoptosis, immunoregulation and anti-inflammation and so forth. The microenvironment of the central nervous system (CNS) can also influence the effects of stem cell therapy. The detailed therapeutic strategies for ICH treatment such as cell type, the number of cells, time window, and the routes of medication delivery, varied greatly among different studies and had not been determined. Moreover, the safety issues of stem cell therapy for ICH should not be ignored. Stem cell therapy showed good therapeutic effect in ICH, making it a promising treatment. However, safety should be carefully evaluated, and more clinical trials are required before stem cell therapy can be extensively applied to clinical use.

  6. Comparison of the different methods for the recovery of suspended matter from estuarine waters: deposition, filtration and centrifugation

    Energy Technology Data Exchange (ETDEWEB)

    Etcheber, H; Jouanneau, J M

    1980-12-01

    The advantages and disadvantages of three methods used to recover heavy metals from estuarine waters are compared. Deposition, filtration, and centrifugation were used on samples from the Gironde estuary of France. Recovery by deposition is satisfactory in cases of flocculation and high turbidity. Centrifugation is reliable for the determination of several elements in zones of low turbidity. (12 references, 4 tables)

  7. VAN method of short-term earthquake prediction shows promise

    Science.gov (United States)

    Uyeda, Seiya

    Although optimism prevailed in the 1970s, the present consensus on earthquake prediction appears to be quite pessimistic. However, short-term prediction based on geoelectric potential monitoring has stood the test of time in Greece for more than a decade [VarotsosandKulhanek, 1993] Lighthill, 1996]. The method used is called the VAN method.The geoelectric potential changes constantly due to causes such as magnetotelluric effects, lightning, rainfall, leakage from manmade sources, and electrochemical instabilities of electrodes. All of this noise must be eliminated before preseismic signals are identified, if they exist at all. The VAN group apparently accomplished this task for the first time. They installed multiple short (100-200m) dipoles with different lengths in both north-south and east-west directions and long (1-10 km) dipoles in appropriate orientations at their stations (one of their mega-stations, Ioannina, for example, now has 137 dipoles in operation) and found that practically all of the noise could be eliminated by applying a set of criteria to the data.

  8. Separating nano graphene oxide from the residual strong-acid filtrate of the modified Hummers method with alkaline solution

    Energy Technology Data Exchange (ETDEWEB)

    Hu, Xuebing, E-mail: xuebinghu2010@gmail.com [Key Laboratory of Inorganic Membrane, Jingdezhen Ceramic Institute, Jingdezhen 333001 (China); Key Laboratory of Inorganic Coating Materials, Shanghai Institute of Ceramics, Chinese Academy of Science, Shanghai 201800 (China); Yu, Yun, E-mail: yunyush@mail.sic.ac.cn [Key Laboratory of Inorganic Coating Materials, Shanghai Institute of Ceramics, Chinese Academy of Science, Shanghai 201800 (China); Wang, Yongqing; Zhou, Jianer [Key Laboratory of Inorganic Membrane, Jingdezhen Ceramic Institute, Jingdezhen 333001 (China); Song, Lixin [Key Laboratory of Inorganic Coating Materials, Shanghai Institute of Ceramics, Chinese Academy of Science, Shanghai 201800 (China)

    2015-02-28

    Graphical abstract: By adding an alkaline (NaOH or KOH) solution, the unprecipitated nano graphene oxide undergoes fast aggregation from the residual strong-acid filtrate of the modified Hummers method and forms the stable floccules when the pH value of the filtrate is about 1.7. The acid–base interaction with the surface functional groups of the carbon layers plays a role in the aggregation of the unprecipitated nano graphene oxide. - Highlights: • The novel and high-efficient method for separating graphene oxide was showed. • Graphene oxide undergoes aggregation and forms the floccules when pH value is ∼1.7. • The acid–base interaction plays a role in the aggregation of graphene oxide. - Abstract: In the modified Hummers method for preparing graphene oxide, the yellow slurry can be obtained. After filtering through a quantitative filter paper, the strong-acid filtrate containing the unprecipitated nano graphene oxide was gained. The corresponding filtrate was added gradually with an alkaline (NaOH or KOH) solution at room temperature. The unprecipitated nano graphene oxide could undergo fast aggregation when the pH value of the filtrate was about 1.7 and formed the stable floccules. X-ray diffraction analysis shows the dominant peak of the floccules is about 11°, which accords to the peak of graphene oxide. Spectra of X-ray photoelectron spectroscopy confirm the presence in the floccules of an abundance of oxygen functional groups and the purified graphene oxide floccules can be obtained. Atomic force microscopy measurement shows the graphene oxide floccules consists of sheet-like objects, mostly containing only a few layers (about 5 layers). Zeta potential analysis demonstrates the surface charge of the graphene oxide is pH-sensitive and its isoelectric point is ∼1.7. The flocculation mechanism of graphene oxide ascribes to the acid–base interaction with the surface functional groups of the carbon layers.

  9. Interactive remote data processing using Pixelize Wavelet Filtration (PWF-method) and PeriodMap analysis

    Science.gov (United States)

    Sych, Robert; Nakariakov, Valery; Anfinogentov, Sergey

    Wavelet analysis is suitable for investigating waves and oscillating in solar atmosphere, which are limited in both time and frequency. We have developed an algorithms to detect this waves by use the Pixelize Wavelet Filtration (PWF-method). This method allows to obtain information about the presence of propagating and non-propagating waves in the data observation (cube images), and localize them precisely in time as well in space. We tested the algorithm and found that the results of coronal waves detection are consistent with those obtained by visual inspection. For fast exploration of the data cube, in addition, we applied early-developed Period- Map analysis. This method based on the Fast Fourier Transform and allows on initial stage quickly to look for "hot" regions with the peak harmonic oscillations and determine spatial distribution at the significant harmonics. We propose the detection procedure of coronal waves separate on two parts: at the first part, we apply the PeriodMap analysis (fast preparation) and than, at the second part, use information about spatial distribution of oscillation sources to apply the PWF-method (slow preparation). There are two possible algorithms working with the data: in automatic and hands-on operation mode. Firstly we use multiply PWF analysis as a preparation narrowband maps at frequency subbands multiply two and/or harmonic PWF analysis for separate harmonics in a spectrum. Secondly we manually select necessary spectral subband and temporal interval and than construct narrowband maps. For practical implementation of the proposed methods, we have developed the remote data processing system at Institute of Solar-Terrestrial Physics, Irkutsk. The system based on the data processing server - http://pwf.iszf.irk.ru. The main aim of this resource is calculation in remote access through the local and/or global network (Internet) narrowband maps of wave's sources both in whole spectral band and at significant harmonics. In addition

  10. Comparison of three different fat graft preparation methods: gravity separation, centrifugation, and simultaneous washing with filtration in a closed system.

    Science.gov (United States)

    Zhu, Min; Cohen, Steven R; Hicok, Kevin C; Shanahan, Rob K; Strem, Brian M; Yu, Johnson C; Arm, Douglas M; Fraser, John K

    2013-04-01

    Successful long-term volume retention of an autologous fat graft is problematic. The presence of contaminating cells, tumescent fluid, and free lipid in the graft contributes to disparate outcomes. Better preparation methods for the fat graft before transplantation may significantly improve results. Subcutaneous fat from 22 donors was divided and processed using various graft preparation methods: (1) no manipulation control, (2) gravity separation, (3) Coleman centrifugation, and (4) simultaneous washing with filtration using a commercially available system (Puregraft; Cytori Therapeutics, Inc., San Diego, Calif.). Fat grafts from various preparation methods were examined for free lipid, aqueous liquid, viable tissue, and blood cell content. Adipose tissue viability was determined by measuring glycerol release after agonist induction of lipolysis. All test graft preparation methods exhibited significantly less aqueous fluid and blood cell content compared with the control. Grafts prepared by washing with filtration exhibited significantly reduced blood cell and free lipid content, with significantly greater adipose tissue viability than other methods. Washing with filtration within a closed system produces a fat graft with higher tissue viability and lower presence of contaminants compared with grafts prepared by alternate methods.

  11. A simple filtration method to remove plankton-associated Vibrio cholerae in raw water supplies in developing countries.

    Science.gov (United States)

    Huq, A; Xu, B; Chowdhury, M A; Islam, M S; Montilla, R; Colwell, R R

    1996-07-01

    Plankton to which cells of Vibrio cholerae O1 and/or O139 were attached was introduced into 0.5% Instant Ocean microcosms maintained at 25 degrees C. The bulk of the plankton and associated particulates was removed with a filter constructed from either nylon net and one of several different types of sari material, the latter being very inexpensive and readily available in villages in Bangladesh, where V. cholerae is endemic. V. cholerae was enumerated before and after filtration to evaluate the efficiency of the filtration procedure. The results obtained indicate that 99% of V. cholerae, i.e., those cells attached to plankton, were removed from the water samples. Epidemic strains of V. cholerae O1 and O139 from various geographical sources, including Bangladesh, Brazil, India, and Mexico, were included in the experiments. Removal of vibrios from water by this simple filtration method was found to yield consistent results with all strains examined in this study. Thus, it is concluded that a simple filtration procedure involving the use of domestic sari material can reduce the number of cholera vibrios attached to plankton in raw water from ponds and rivers commonly used for drinking. Since untreated water from such sources serves as drinking water for millions of people living in developing countries (e.g., Bangladesh), filtration should prove effective at reducing the incidence and severity of outbreaks, especially in places that lack fuel wood for boiling water and/or municipal water treatment plants. The results of this study provide the basis for determining such reductions, which are to be carried out in the near future.

  12. Algorithmic impediments filtration using the α-truncated mean method in resolver-to-digital converter

    Directory of Open Access Journals (Sweden)

    Gordiyenko V. I.

    2009-02-01

    Full Text Available A test diagram of the microcontroller-type resolver-to-digital converter and algorithms for impediments filtration therein are developed. Experimental verification of the α-truncated mean algorithm intended for the suppression of impulse and noise interference is conducted. The test results are given.

  13. Comparative evaluation of quantitative glomerular filtration rate measured by isotopic and nonisotopic methods

    International Nuclear Information System (INIS)

    Balachandran, S.; Toguri, A.G.; Petrusick, T.W.; Abbott, L.C.

    1981-01-01

    Good correlation of glomerular filtration rate (GFR) measured isotopically from plasma disappearance of Tc-99m-DTPA (Sn) was shown with inulin clearance, creatinine clearance, and graded radionuclide imaging. The isotopic GFR is a simple, urineless technique not requiring continuous infusion that enables one to perform simultaneous renal imaging with one radiotracer

  14. Development of new cleanup method of polychlorinated dibenzo-p-dioxins/dibenzofurans in fish by freezing-lipid filtration

    Energy Technology Data Exchange (ETDEWEB)

    Ahn, Yun Gyong [Hazardous Substance Research Team, Korea Basic Science Institute, Seoul 136-701 (Korea, Republic of); Seo, Jungju [Hazardous Substance Research Team, Korea Basic Science Institute, Seoul 136-701 (Korea, Republic of); Shin, Jeoung Hwa [Hazardous Substance Research Team, Korea Basic Science Institute, Seoul 136-701 (Korea, Republic of); Khim, Jeehyeong [Department of Civil Environment Engineering, Korea University, Seoul 136-701 (Korea, Republic of); Hong, Jongki [College of Pharmacy, Kyung Hee University, Hoegi-Dong, Dongdaemoon-Ku, Seoul 130-701 (Korea, Republic of)]. E-mail: jhong@khu.ac.kr

    2006-08-18

    Freezing-lipid filtration as a new method has been developed for the rapid determination of polychlorinated dibenzo-p-dioxins/dibenzofurans (PCDDs/Fs) in biological samples. This method can effectively reduce the time of sample pretreatment, labor and amount of solvents compared with conventional methods. By freezing-lipid filtration procedure, about 90% of lipids in extract could be removed without any significant loss of PCDD/Fs. For further cleanup of extracts after freezing-lipid filtration, automatic parallel LC columns including silica gel, alumina and carbon columns were applied. During automatic parallel LC columns cleanup, most of co-extracted interferences such as residue lipids and fatty acids could be eliminated and dioxins could be separated from many other dioxin-like congeners such as polychlorinated biphenyls by this procedure. The extracts after cleanup were analyzed by high-resolution gas chromatography (HRGC)/high-resolution mass spectrometry (HRMS) using an isotope dilution method. The average recoveries and relative standard deviation (R.S.D.) of 17 native congeners in the spiked fish samples at 8-80 pg/g (n = 3) were ranged between 85.3 and 117.2% and 5.7-20.3%, respectively.

  15. Development of new cleanup method of polychlorinated dibenzo-p-dioxins/dibenzofurans in fish by freezing-lipid filtration

    International Nuclear Information System (INIS)

    Ahn, Yun Gyong; Seo, Jungju; Shin, Jeoung Hwa; Khim, Jeehyeong; Hong, Jongki

    2006-01-01

    Freezing-lipid filtration as a new method has been developed for the rapid determination of polychlorinated dibenzo-p-dioxins/dibenzofurans (PCDDs/Fs) in biological samples. This method can effectively reduce the time of sample pretreatment, labor and amount of solvents compared with conventional methods. By freezing-lipid filtration procedure, about 90% of lipids in extract could be removed without any significant loss of PCDD/Fs. For further cleanup of extracts after freezing-lipid filtration, automatic parallel LC columns including silica gel, alumina and carbon columns were applied. During automatic parallel LC columns cleanup, most of co-extracted interferences such as residue lipids and fatty acids could be eliminated and dioxins could be separated from many other dioxin-like congeners such as polychlorinated biphenyls by this procedure. The extracts after cleanup were analyzed by high-resolution gas chromatography (HRGC)/high-resolution mass spectrometry (HRMS) using an isotope dilution method. The average recoveries and relative standard deviation (R.S.D.) of 17 native congeners in the spiked fish samples at 8-80 pg/g (n = 3) were ranged between 85.3 and 117.2% and 5.7-20.3%, respectively

  16. Verification on the use of the Inoue method for precisely determining glomerular filtration rate in Philippine pediatrics

    Science.gov (United States)

    Magcase, M. J. D. J.; Duyan, A. Q.; Carpio, J.; Carbonell, C. A.; Trono, J. D.

    2015-06-01

    The objective of this study is to validate the Inoue method so that it would be the preferential choice in determining glomerular filtration rate (GFR) in Philippine pediatrics. The study consisted of 36 patients ranging from ages 2 months to 19 years old. The subjects used were those who were previously subjected to in-vitro method. The scintigrams of the invitro method was obtained and processed for split percentage uptake and for parameters needed to obtain Inoue GFR. The result of this paper correlates the Inoue GFR and In-vitro method (r = 0.926). Thus, Inoue method is a viable, simple, and practical technique in determining GFR in pediatric patients.

  17. A method to generate equivalent energy spectra and filtration models based on measurement for multidetector CT Monte Carlo dosimetry simulations

    International Nuclear Information System (INIS)

    Turner, Adam C.; Zhang Di; Kim, Hyun J.; DeMarco, John J.; Cagnon, Chris H.; Angel, Erin; Cody, Dianna D.; Stevens, Donna M.; Primak, Andrew N.; McCollough, Cynthia H.; McNitt-Gray, Michael F.

    2009-01-01

    The purpose of this study was to present a method for generating x-ray source models for performing Monte Carlo (MC) radiation dosimetry simulations of multidetector row CT (MDCT) scanners. These so-called ''equivalent'' source models consist of an energy spectrum and filtration description that are generated based wholly on the measured values and can be used in place of proprietary manufacturer's data for scanner-specific MDCT MC simulations. Required measurements include the half value layers (HVL 1 and HVL 2 ) and the bowtie profile (exposure values across the fan beam) for the MDCT scanner of interest. Using these measured values, a method was described (a) to numerically construct a spectrum with the calculated HVLs approximately equal to those measured (equivalent spectrum) and then (b) to determine a filtration scheme (equivalent filter) that attenuates the equivalent spectrum in a similar fashion as the actual filtration attenuates the actual x-ray beam, as measured by the bowtie profile measurements. Using this method, two types of equivalent source models were generated: One using a spectrum based on both HVL 1 and HVL 2 measurements and its corresponding filtration scheme and the second consisting of a spectrum based only on the measured HVL 1 and its corresponding filtration scheme. Finally, a third type of source model was built based on the spectrum and filtration data provided by the scanner's manufacturer. MC simulations using each of these three source model types were evaluated by comparing the accuracy of multiple CT dose index (CTDI) simulations to measured CTDI values for 64-slice scanners from the four major MDCT manufacturers. Comprehensive evaluations were carried out for each scanner using each kVp and bowtie filter combination available. CTDI experiments were performed for both head (16 cm in diameter) and body (32 cm in diameter) CTDI phantoms using both central and peripheral measurement positions. Both equivalent source model types

  18. Large-scale photochemical reactions of nanocrystalline suspensions: a promising green chemistry method.

    Science.gov (United States)

    Veerman, Marcel; Resendiz, Marino J E; Garcia-Garibay, Miguel A

    2006-06-08

    Photochemical reactions in the solid state can be scaled up from a few milligrams to 10 grams by using colloidal suspensions of a photoactive molecular crystal prepared by the solvent shift method. Pure products are recovered by filtration, and the use of H(2)O as a suspension medium makes this method a very attractive one from a green chemistry perspective. Using the photodecarbonylation of dicumyl ketone (DCK) as a test system, we show that reaction efficiencies in colloidal suspensions rival those observed in solution. [reaction: see text

  19. Effect of filtration of signals of brain activity on quality of recognition of brain activity patterns using artificial intelligence methods

    Science.gov (United States)

    Hramov, Alexander E.; Frolov, Nikita S.; Musatov, Vyachaslav Yu.

    2018-02-01

    In present work we studied features of the human brain states classification, corresponding to the real movements of hands and legs. For this purpose we used supervised learning algorithm based on feed-forward artificial neural networks (ANNs) with error back-propagation along with the support vector machine (SVM) method. We compared the quality of operator movements classification by means of EEG signals obtained experimentally in the absence of preliminary processing and after filtration in different ranges up to 25 Hz. It was shown that low-frequency filtering of multichannel EEG data significantly improved accuracy of operator movements classification.

  20. A Filtration-based Method of Preparing High-quality Nuclei from Cross-linked Skeletal Muscle for Chromatin Immunoprecipitation.

    Science.gov (United States)

    Nohara, Kazunari; Chen, Zheng; Yoo, Seung-Hee

    2017-07-06

    Chromatin immunoprecipitation (ChIP) is a powerful method to determine protein binding to chromatin DNA. Fiber-rich skeletal muscle, however, has been a challenge for ChIP due to technical difficulty in isolation of high-quality nuclei with minimal contamination of myofibrils. Previous protocols have attempted to purify nuclei before cross-linking, which incurs the risk of altered DNA-protein interaction during the prolonged nuclei preparation process. In the current protocol, we first cross-linked the skeletal muscle tissue collected from mice, and the tissues were minced and sonicated. Since we found that ultracentrifugation was not able to separate nuclei from myofibrils using cross-linked muscle tissue, we devised a sequential filtration procedure to obtain high-quality nuclei devoid of significant myofibril contamination. We subsequently prepared chromatin by using an ultrasonicator, and ChIP assays with anti-BMAL1 antibody revealed robust circadian binding pattern of BMAL1 to target gene promoters. This filtration protocol constitutes an easily applicable method to isolate high-quality nuclei from cross-linked skeletal muscle tissue, allowing consistent sample processing for circadian and other time-sensitive studies. In combination with next-generation sequencing (NGS), our method can be deployed for various mechanistic and genomic studies focusing on skeletal muscle function.

  1. Comparison of glomerular filtration rates by dynamic renal scintigraphy and dual-plasma sample clearance method in diabetic nephropathy

    International Nuclear Information System (INIS)

    Xie Peng; Huang Jianmin; Pan Liping; Liu Xiaomei; Wei Lingge; Gao Jianqing

    2010-01-01

    Objective: To evaluate the accuracy of renal scintigraphy for the estimation of glomerular filtration rates (dGFR) in patients with diabetic nephropathy as compared to the conventional dual-plasma sample clearance method (pscGFR). Methods: Forty-six patients with diabetic nephropathy underwent both dynamic renal scintigraphy and dual-plasma sample measurement after 99 Tc m -DTPA injection. Paired student t-test and correlation analysis were performed to compare dGFR and pscGFR (normalized to body surface area, 1.73 m -2 ). Results: The mean dGFR was higher than mean pscGFR ((51.08±26.78)ml·min -1 vs (44.06±29.43)ml·min -1 , t=4.209, P=0.000). The dGFR correlated with pscGFR (r=0.923, P=0.000) linearly (regression equation: pscGFR=1.015 x dGFR -7.773, F=254.656, P=0.000). Conclusions: dGFR correlated well with pscGFR. Although it could not absolutely replace the latter in patients with diabetic nephropathy, dGFR could reasonably evaluate the filtration function for these patients. (authors)

  2. Comparison of methods for estimating glomerular filtration rate in head and neck cancer patients treated with cisplatin

    DEFF Research Database (Denmark)

    Lindberg, Lotte; Brødbæk, Kasper; Hägerström, Erik G

    2017-01-01

    Cisplatin is a chemotherapeutic agent widely used in the treatment of various solid tumors. Cisplatin induces nephrotoxicity and may lead to long-term reduction of kidney function. Consequently, determination of glomerular filtration rate (GFR) is used to monitor potential kidney damage. This study...... aimed to compare two commonly used algorithms for estimating GFR (eGFR) from plasma creatinine (PCr) with 51Cr-EDTA clearance (CrCl) as a reference method. This was a retrospective single center study of 94 head and neck cancer patients treated with cisplatin. CrCl was performed once before, during......, and after treatment, and PCr was measured concurrently. eGFR was assessed from PCr applying the Cockcroft-Gault (CG) and the Chronic Kidney Disease-Epidemiology Collaboration (CKD-EPI) equations. Agreement was assessed applying the statistical methods of Bland and Altman. A predefined limit of clinically...

  3. Evaluation of bank filtration as a pretreatment method for the provision of hygienically safe drinking water in Norway: results from monitoring at two full-scale sites

    Science.gov (United States)

    Kvitsand, Hanne M. L.; Myrmel, Mette; Fiksdal, Liv; Østerhus, Stein W.

    2017-08-01

    Two case studies were carried out in central Norway in order to assess the performance of bank filtration systems in cold-climate fluvial aquifers relying on recharge from humic-rich surface waters with moderate microbial contamination. Three municipal wells and two surface-water sources at operative bank filtration systems were monitored for naturally occurring bacteriophages, fecal indicators, natural organic matter (NOM) and physico-chemical water quality parameters during a 4-month period. Aquifer passage effectively reduced the microorganism and NOM concentrations at both study sites. Bacteriophages were detected in 13 of 16 (81%) surface-water samples and in 4 of 24 (17%) well-water samples, and underwent 3 ± 0.3 log10 reduction after 50-80-m filtration and 20-30 days of subsurface passage. NOM reductions (color: 74-97%; dissolved organic carbon: 54-80%; very hydrophobic acids: 70%) were similar to those achieved by conventional water-treatment processes and no further treatment was needed. Both groundwater dilution and sediment filtration contributed to the hygienic water quality improvements, but sediment filtration appeared to be the most important process with regard to microbial and NOM reductions. A strengths-weaknesses-opportunities-threats analysis showed that bank filtration technology has a high potential as a pretreatment method for the provision of hygienically safe drinking water in Norway.

  4. A Comprehensive Software and Database Management System for Glomerular Filtration Rate Estimation by Radionuclide Plasma Sampling and Serum Creatinine Methods.

    Science.gov (United States)

    Jha, Ashish Kumar

    2015-01-01

    Glomerular filtration rate (GFR) estimation by plasma sampling method is considered as the gold standard. However, this method is not widely used because the complex technique and cumbersome calculations coupled with the lack of availability of user-friendly software. The routinely used Serum Creatinine method (SrCrM) of GFR estimation also requires the use of online calculators which cannot be used without internet access. We have developed user-friendly software "GFR estimation software" which gives the options to estimate GFR by plasma sampling method as well as SrCrM. We have used Microsoft Windows(®) as operating system and Visual Basic 6.0 as the front end and Microsoft Access(®) as database tool to develop this software. We have used Russell's formula for GFR calculation by plasma sampling method. GFR calculations using serum creatinine have been done using MIRD, Cockcroft-Gault method, Schwartz method, and Counahan-Barratt methods. The developed software is performing mathematical calculations correctly and is user-friendly. This software also enables storage and easy retrieval of the raw data, patient's information and calculated GFR for further processing and comparison. This is user-friendly software to calculate the GFR by various plasma sampling method and blood parameter. This software is also a good system for storing the raw and processed data for future analysis.

  5. Fast Swinnex Filtration (FSF): A fast and robust sampling and extraction method suitable for metabolomics analysis of cultures grown in complex media

    DEFF Research Database (Denmark)

    McCloskey, Douglas; Utrilla, Jose; Naviaux, Robert K.

    2015-01-01

    , we develop a fast-filtration method using pressuredriven Swinnex filters. We show that the method is fast enough to provide an accurate snapshot of intracellular metabolism, reduces matrix interference from the media to improve the number of compounds that can be detected, and is applicable...... to anaerobic and aerobic liquid cultures grown in a variety of culturing systems. Furthermore, we apply the fast filtration method to investigate differences in the absolute intracellular metabolite levels of anaerobic cultures grown in minimal and complex media....

  6. Measurement of glomerular filtration rate using technetium-99m-DTPA and the gamma camera: A comparison of methods

    International Nuclear Information System (INIS)

    Russell, C.D.; Bischoff, P.G.; Kontzen, F.; Rowell, K.L.; Yester, M.V.; Lloyd, L.K.; Tauxe, W.N.; Dubovsky, E.V.

    1984-01-01

    A variety of methods has been proposed to estimate glomerular filtration rate (GFR) from renal uptake of Tc-99m-DTPA using a gamma camera. To compare alternative methods, the authors have calculated GFR in several different ways from measurements in 33 patients, and compared the results with an independent GFR measurement based on 8-point plasma clearance of Yb-169-DTPA. The best agreement was obtained using an algorithm that has not been described previously. This was a modification of a method used previously in which correction was made for overlap of kidneys by liver and spleen. The correlation coefficient was 0.958 and the residual standard deviation was 12.1 ml/min. This method required a single 20-min blood sample as well as the camera data. The best method not requiring a blood sample was significantly less accurate, with correlation coefficient 0.866 and residual standard deviation 21.1 ml/min. The accuracy of these methods was comparable to that reported for the creatinine clearance, the most commonly used estimate of GFR in current clinical practice

  7. Aerosol filtration

    International Nuclear Information System (INIS)

    Klein, M.; Goossens, W.R.A.; De Smet, M.; Trine, J.; Hertschap, M.

    1984-01-01

    This report summarizes the work on the development of fibre metallic prefilters to be placed upstream of HEPA filters for the exhaust gases of nuclear process plants. Investigations at ambient and high temperature were carried out. Measurements of the filtration performance of Bekipor porous webs and sintered mats were performed in the AFLT (aerosol filtration at low temperature) unit with a throughput of 15 m 3 /h. A parametric study on the influence of particle size, fibre diameter, number of layers and superficial velocity led to the optimum choice of the working parameters. Three selected filter types were then tested with polydisperse aerosols using a candle-type filter configuration or a flat-type filter configuration. The small-diameter candle type is not well suited for a spraying nozzles regeneration system so that only the flat-type filter was retained for high-temperature tests. A high-temperature test unit (AFHT) with a throughput of 8 to 10 m 3 /h at 400 0 C was used to test the three filter types with an aerosol generated by high-temperature calcination of a simulated nitric acid waste solution traced with 134 Cs. The regeneration of the filter by spray washing and the effect of the regeneration on the filter performance was studied for the three filter types. The porous mats have a higher dust loading capacity than the sintered web which means that their regeneration frequency can be kept lower

  8. Purification and differentiation of human adipose-derived stem cells by membrane filtration and membrane migration methods

    Science.gov (United States)

    Lin, Hong Reng; Heish, Chao-Wen; Liu, Cheng-Hui; Muduli, Saradaprasan; Li, Hsing-Fen; Higuchi, Akon; Kumar, S. Suresh; Alarfaj, Abdullah A.; Munusamy, Murugan A.; Hsu, Shih-Tien; Chen, Da-Chung; Benelli, Giovanni; Murugan, Kadarkarai; Cheng, Nai-Chen; Wang, Han-Chow; Wu, Gwo-Jang

    2017-01-01

    Human adipose-derived stem cells (hADSCs) are easily isolated from fat tissue without ethical concerns, but differ in purity, pluripotency, differentiation ability, and stem cell marker expression, depending on the isolation method. We isolated hADSCs from a primary fat tissue solution using: (1) conventional culture, (2) a membrane filtration method, (3) a membrane migration method where the primary cell solution was permeated through membranes, adhered hADSCs were cultured, and hADSCs migrated out from the membranes. Expression of mesenchymal stem cell markers and pluripotency genes, and osteogenic differentiation were compared for hADSCs isolated by different methods using nylon mesh filter membranes with pore sizes ranging from 11 to 80 μm. hADSCs isolated by the membrane migration method had the highest MSC surface marker expression and efficient differentiation into osteoblasts. Osteogenic differentiation ability of hADSCs and MSC surface marker expression were correlated, but osteogenic differentiation ability and pluripotent gene expression were not. PMID:28071738

  9. Errors in the determination of the total filtration of diagnostic x-ray tubes by the HVL method

    International Nuclear Information System (INIS)

    Gilmore, B.J.; Cranley, K.

    1990-01-01

    Optimal technique and an analysis of errors are essential for interpreting whether the total filtration of a diagnostic x-ray tube is acceptable. The study discusses this problem from a theoretical viewpoint utilising recent theoretical HVL-total-filtration data relating to 10 0 and 16 0 tungsten target angles and 0-30% kilovoltage ripples. The theory indicates the typical accuracy to which each appropriate parameter must be determined to maintain acceptable errors in total filtration. A quantitative approach is taken to evaluate systematic errors in a technique for interpolation of HVL from raw attenuation curve data. A theoretical derivation is presented to enable random errors in HVL due to x-ray set inconsistency to be estimated for particular experimental techniques and data analysis procedures. Further formulae are presented to enable errors in the total filtration estimate to be readily determined from those in the individual parameters. (author)

  10. Preparation of regenerable granular carbon nanotubes by a simple heating-filtration method for efficient removal of typical pharmaceuticals

    Science.gov (United States)

    Shan, Danna; Deng, Shubo; Zhao, Tianning; Yu, Gang; Winglee, Judith; Wiesner, Mark R.

    2017-04-01

    A simple and convenient method was used to prepare novel granular carbon nanotubes (CNTs) for enhanced adsorption of pharmaceuticals. By heating CNTs powder at 450 degree centigrade in air, followed by filtration, the obtained granular adsorbent exhibited high surface area and pore volume since the heating process produced some oxygen-containing functional groups on CNT surface, making CNTs more dispersible in the formation of granular cake. The porous granular CNTs not only had more available surfaces for adsorption but also were more easily separated from solution than pristine CNTs (p-CNTs) powder. This adsorbent exhibited relatively fast adsorption for carbamazepine (CBZ), tetracycline (TC) and diclofe- nac sodium (DS), and the maximum adsorption capacity on the granular CNTs was 369.5 μmol/g for CBZ, 284.2 μmol/g for TC and 203.1 μmol/g for DS according to the Langmuir fitting, increasing by 42.4%, 37.8% and 38.0% in comparison with the pristine CNTs powder. Moreover, the spent granular CNTs were successfully regenerated at 400 degree centigrade in air without decreasing the adsorption capacity in five regeneration cycles. The adsorbed CBZ and DS were completely degraded, while the adsorbed TC was partially oxidized and the residual was favorable for the subsequent adsorption. This research develops an easy method to prepare and regenerate granular CNT adsorbent for the enhanced removal of organic pollutants from water or wastewater.

  11. Filtration through nylon membranes negatively affects analysis of arsenic and phosphate by the molybdenum blue method

    DEFF Research Database (Denmark)

    Heimann, Axel Colin; Jakobsen, Rasmus

    2007-01-01

    Filtering synthetic arsenic- or phosphate-containing solutions (1.5-47.6 mu mol/L) with nylon syringe filters significantly reduced absorbances (by 6-74%) when analyzed with the colorimetric molybdenum blue method. Filtering the same solutions with cellulose acetate syringe filters yielded...... no significant differences as compared to unfiltered controls. The detrimental effect of nylon membranes was also observed when pure Milli-Q water was filtered and Subsequently spiked with arsenic(III) or phosphate suggesting that some compound(s) eluting from the filter membranes interfere with the color...... formation in the assay. Consequently, we caution against using nylon filters when filtering water samples for the determination of arsenic or phosphate with the molybdenum blue method....

  12. Selection of Filtration Methods in the Analysis of Motion of Automated Guided Vehicle

    Directory of Open Access Journals (Sweden)

    Dobrzańska Magdalena

    2016-08-01

    Full Text Available In this article the issues related to mapping the route and error correction in automated guided vehicle (AGV movement have been discussed. The nature and size of disruption have been determined using the registered runs in experimental studies. On the basis of the analysis a number of numerical runs have been generated, which mapped possible to obtain runs in a real movement of the vehicle. The obtained data set has been used for further research. The aim of this paper was to test the selected methods of digital filtering on the same data set and determine their effectiveness. The results of simulation studies have been presented in the article. The effectiveness of various methods has been determined and on this basis the conclusions have been drawn.

  13. Rapid filtration separation-based sample preparation method for Bacillus spores in powdery and environmental matrices.

    Science.gov (United States)

    Isabel, Sandra; Boissinot, Maurice; Charlebois, Isabelle; Fauvel, Chantal M; Shi, Lu-E; Lévesque, Julie-Christine; Paquin, Amélie T; Bastien, Martine; Stewart, Gale; Leblanc, Eric; Sato, Sachiko; Bergeron, Michel G

    2012-03-01

    Authorities frequently need to analyze suspicious powders and other samples for biothreat agents in order to assess environmental safety. Numerous nucleic acid detection technologies have been developed to detect and identify biowarfare agents in a timely fashion. The extraction of microbial nucleic acids from a wide variety of powdery and environmental samples to obtain a quality level adequate for these technologies still remains a technical challenge. We aimed to develop a rapid and versatile method of separating bacteria from these samples and then extracting their microbial DNA. Bacillus atrophaeus subsp. globigii was used as a simulant of Bacillus anthracis. We studied the effects of a broad variety of powdery and environmental samples on PCR detection and the steps required to alleviate their interference. With a benchmark DNA extraction procedure, 17 of the 23 samples investigated interfered with bacterial lysis and/or PCR-based detection. Therefore, we developed the dual-filter method for applied recovery of microbial particles from environmental and powdery samples (DARE). The DARE procedure allows the separation of bacteria from contaminating matrices that interfere with PCR detection. This procedure required only 2 min, while the DNA extraction process lasted 7 min, for a total of sample preparation procedure allowed the recovery of cleaned bacterial spores and relieved detection interference caused by a wide variety of samples. Our procedure was easily completed in a laboratory facility and is amenable to field application and automation.

  14. GSPEL - Air Filtration Laboratory

    Data.gov (United States)

    Federal Laboratory Consortium — Evaluation capabilities for air filtration devicesThe Air Filtration Lab provides testing of air filtration devices to demonstrate and validate new or legacy system...

  15. [Membrane-filtration immunoassay: reagents, methods and the diagnostic and technical means for detection].

    Science.gov (United States)

    Khramov, E N; Osin, N S; Pomelova, V G; Vikha, I V; Bychenkova, T A; Smirnova, V G; Grakina, G I; Kas'ianova, T A

    1999-01-01

    The comprehensive development of dot-EIA made at the State Research Institute of Biological Instrument-Making Industry has provided devices KIMF-02 and KIMF-03), a base of chemical reagents, immunoassays, test systems for detection of a wide range of causative agents of viral and bacterial infections, that of serodiagnosis of their related diseases. The KIMF-02 kit has undergone engineering and medical tests and recommended for the Ministry of Health of the Russian Federation to produce them in stock. The kit includes all required for analysis even in an ill-equipped laboratory, a set of attached agents ensures a valid visual recording of results. The developed procedures and test systems allow the immunoassay to be as sensitive as TIFA; however, they are laborious and much simpler in design. The simple and rapid procedures of dot-EIA are recommended for incorporation into the a package of laboratory methods for verification of the accumulation of virus-specific antigens in various biological substrata, environmental samples, for control of the activity of antigens and antibodies used in serological tests, for detection of specific antigens in the clinical samples, and for serodiagnosis of infections.

  16. The filter of choice: filtration method preference among injecting drug users

    Directory of Open Access Journals (Sweden)

    Keijzer Lenneke

    2011-08-01

    Full Text Available Abstract Background Injection drug use syringe filters (IDUSF are designed to prevent several complications related to the injection of drugs. Due to their small pore size, their use can reduce the solution's insoluble particle content and thus diminish the prevalence of phlebitis, talcosis.... Their low drug retention discourages from filter reuse and sharing and can thus prevent viral and microbial infections. In France, drug users have access to sterile cotton filters for 15 years and to an IDUSF (the Sterifilt® for 5 years. This study was set up to explore the factors influencing filter preference amongst injecting drug users. Methods Quantitative and qualitative data were gathered through 241 questionnaires and the participation of 23 people in focus groups. Results Factors found to significantly influence filter preference were duration and frequency of injecting drug use, the type of drugs injected and subculture. Furthermore, IDU's rationale for the preference of one type of filter over others was explored. It was found that filter preference depends on perceived health benefits (reduced harms, prevention of vein damage, protection of injection sites, drug retention (low retention: better high, protective mechanism against the reuse of filters; high retention: filter reuse as a protective mechanism against withdrawal, technical and practical issues (filter clogging, ease of use, time needed to prepare an injection and believes (the conviction that a clear solution contains less active compound. Conclusion It was concluded that the factors influencing filter preference are in favour of change; a shift towards the use of more efficient filters can be made through increased availability, information and demonstrations.

  17. [Promising new injection method to prevent angialgia/phlebitis from epirubicin hydrochloride therapy for breast cancer].

    Science.gov (United States)

    Ono, Chiemi; Yamagami, Mitsue; Kamatani, Rika; Yamamoto, Makoto; Mukouyama, Tomoya; Sugimoto, Masakazu; Suzuki, Taizan; Kamo, Nobuyuki; Seki, Nobuhiko; Eguchi, Kenji; Ikeda, Tadashi

    2012-05-01

    Epirubicin hydrochloride(EPI)is well known to cause phlebitis as a typical adverse drug reaction. By preventing the development of severe phlebitis, patients are expected to continue effective chemotherapy with EPI without a decrease in QOL. We have previously reported promising results of a new injection method to prevent phlebitis from occurring during EPI therapy thorough a prospective clinical trial in our hospital(Jpn J Cancer Chemother 36: 969-974, 2009). In the present study, we have compared the conventional injection method(EPI main -route method, n=15)with our new method, which has been consistently practiced at present(EPI sub -route method, n=77). We found that in the EPI main -route method, angialgia/phlebitis developed in 14 of 15 cases(Grade 3, 53. 3%), leading to alteration of the regimen in 3 cases. On the other hand, with the EPI sub -route method, incidence of angialgia/phlebitis was markedly decreased, and only 6 of 77 cases developed these adverse reactions(Grade 3, 0%). One possible explanation for these results is that the reduction of intimal stimulation by the EPI sub -route method might be caused by the dilution and washout of EPI with pre-medication, as well as the shortened infusion times of EPI. Therefore, on the basis of the above hypothesis, we conclude that the EPI sub-route method might be a more effective treatment for the expected prevention of angialgia/phlebitis.

  18. Removal of Heavy Metals and Organic Contaminants from Wwater by Novel Filtration Methods. Final report

    International Nuclear Information System (INIS)

    Rodriguez, N.M.

    2000-01-01

    The removal of hazardous waste, generated by the dismantling of nuclear weapons is a problem that requires urgent attention by the US Department of Energy. Low levels of radioactive contaminants combined with organic solvent residues have leaked from aging containers into the soil and underground water in the surrounding area. Due to the complexity of the problem, it is evident that traditional adsorption methods are ineffective, since the adsorbent tends to saturate with the aqueous component. It has become apparent that a much more aggressive approach is required which involves the use of specially designed materials. We have investigated the potential of solids that combine high surface area/high pore volume and high electrical conductivity, a rare combination of properties found in a single material. In this program we examined the potential of newly developed materials for the trapping of organic solvents within specially engineered cavities without allowing the material to become saturated with water. Catalytically grown carbon nanofibers are a set of novel structures that are produced by the decomposition of selected carbon-containing gases over metal particles. These materials consist of extremely small graphite platelets stacked in various orientations with respect to the fiber axis. Such an arrangement results in a unique structure that is composed of an infinite number of extremely short and narrow pores, suitable for sequestering small molecules. In addition, when the graphene layers are aligned parallel to the fiber axis, an unusual combination of high surface area and low electrical resistivity solids are attained. We have attempted to capitalize on this blend of properties by using such structures for the selective removal of organic contaminants from aqueous streams. Experimental results indicate that nanofibers possessing a structure in which the graphite platelets are aligned perpendicular to the fiber axis and possessing a high degree of

  19. No Impact of the Analytical Method Used for Determining Cystatin C on Estimating Glomerular Filtration Rate in Children.

    Science.gov (United States)

    Alberer, Martin; Hoefele, Julia; Benz, Marcus R; Bökenkamp, Arend; Weber, Lutz T

    2017-01-01

    Measurement of inulin clearance is considered to be the gold standard for determining kidney function in children, but this method is time consuming and expensive. The glomerular filtration rate (GFR) is on the other hand easier to calculate by using various creatinine- and/or cystatin C (Cys C)-based formulas. However, for the determination of serum creatinine (Scr) and Cys C, different and non-interchangeable analytical methods exist. Given the fact that different analytical methods for the determination of creatinine and Cys C were used in order to validate existing GFR formulas, clinicians should be aware of the type used in their local laboratory. In this study, we compared GFR results calculated on the basis of different GFR formulas and either used Scr and Cys C values as determined by the analytical method originally employed for validation or values obtained by an alternative analytical method to evaluate any possible effects on the performance. Cys C values determined by means of an immunoturbidimetric assay were used for calculating the GFR using equations in which this analytical method had originally been used for validation. Additionally, these same values were then used in other GFR formulas that had originally been validated using a nephelometric immunoassay for determining Cys C. The effect of using either the compatible or the possibly incompatible analytical method for determining Cys C in the calculation of GFR was assessed in comparison with the GFR measured by creatinine clearance (CrCl). Unexpectedly, using GFR equations that employed Cys C values derived from a possibly incompatible analytical method did not result in a significant difference concerning the classification of patients as having normal or reduced GFR compared to the classification obtained on the basis of CrCl. Sensitivity and specificity were adequate. On the other hand, formulas using Cys C values derived from a compatible analytical method partly showed insufficient

  20. Estimation in adults of the glomerular filtration rate in [99mTc] DTPA renography - the rate constant method

    International Nuclear Information System (INIS)

    Carlsen, Ove

    2004-01-01

    The purpose of this study was to design an alternative and robust method for estimation of glomerular filtration rate (GFR) in [ 99 mTc]-diethylenetriaminepentaacetic acid ([ 99 mTc] -DTPA renography with a reliability not significantly lower than that of the conventional Gates' method. Methods: The method is based on renographies lasting 40 min in which regions of interest (ROIs) are manually created over selected parts of certain blood pools (e.g. heart, lungs, spleen, and liver). For each ROI the corresponding time-activity curve (TAC) was generated, decay corrected and exposed to a monoexponential fit in the time interval 10 to 40 min postinjection. The rate constant in min-1 of the monoexponential fit was denoted BETA. Following an iterative procedure comprising usually 5-10 manually created ROIs, the monoexponential fit with the maximum rate constant (BETA max ) was used for estimation of GFR. Results: In a patient material of 54 adult subjects in whom GFR was determined with multiple or one sample techniques with [ 51 Cr]-ethylenediaminetetraacetic acid ([ 51 Cr]-EDTA) the regression curve of standard GFR (GFR std ) (i.e. GFR adjusted to 1.73 m 2 body surface area) showed a close, non-linear relationship with BETA max with a correlation coefficient of 95%. The standard errors of estimate (SEE) were 6.6, 10.6 and 16.8 for GFR std equal to 30, 60, and 120 ml/(min .73 m 2 ), respectively. The corresponding SEE values for almost the same patient material using Gates' method were 8.4, 11.9, and 16.8 ml/(min 1.73 m 2 ). Conclusions: The alternative rate constant method yields estimates of GFR std with SEE values equal to or slightly smaller than in Gates' method. The two methods provide statistically uncorrelated estimates of GFR std . Therefore, pooled estimates of GFR std can be calculated with SEE values approximately 1.41 times smaller than those mentioned above. The reliabilities of the pooled estimate of GFR std separately and of the multiple samples method

  1. Problems of multiphase fluid filtration

    CERN Document Server

    Konovalov, AN

    1994-01-01

    This book deals with a spectrum of problems related to the mathematical modeling of multiphase filtration. Emphasis is placed on an inseparable triad: model - algorithm - computer code. An analysis of new and traditional filtration problems from the point of view of both their numerical implementation and the reproduction of one or another technological characteristics of the processes under consideration is given. The basic principles which underlie the construction of efficient numerical methods taking into account the filtration problems are discussed: non-evolutionary nature, degeneration,

  2. Assessment of the microbial growth potential of slow sand filtrate with the biomass production potential test in comparison with the assimilable organic carbon method.

    Science.gov (United States)

    van der Kooij, Dick; Veenendaal, Harm R; van der Mark, Ed J; Dignum, Marco

    2017-11-15

    Slow sand filtration is the final treatment step at four surface-water supplies in the Netherlands. The microbial growth potential (MGP) of the finished water was measured with the assimilable organic carbon (AOC) method using pure cultures and the biomass production potential (BPP) test. In the BPP test, water samples were incubated untreated at 25 °C and the active-biomass concentration was measured by adenosine tri-phosphate (ATP) analysis. Addition of a river-water inoculum improved the test performance and characteristic growth and maintenance profiles of the water were obtained. The maximum ATP concentration attained within seven days and the cumulative biomass production after 14 days of incubation (BPC 14 , d ng ATP L -1 ) showed highly significant and strong linear relationships with the AOC in the slow sand filtrates. The lowest AOC and BPC 14 levels were observed in the supplies applying dune filtration without ozonation in post treatment, with AOC/TOC = 1.7 ± 0.3 μg acetate-C equivalents mg -1 C and BPC 14 /TOC = 16.3 ± 2.2 d ng ATP mg -1 C, corresponding with 1.2 ± 0.19 ng ATP mg -1 C. These characteristics may represent the lowest specific MGP of natural organic matter achievable by biofiltration at temperatures ≤20 °C. The AOC and BPC 14 concentrations in the slow sand filtrate of the supply treating lake water by ozonation with granular-activated-carbon filtration and slow sand filtration as post treatment increased with decreasing temperature. The BPP test revealed that this slow sand filtrate sampled at 2 °C contained growth-promoting compounds that were not detected with the AOC test. These observations demonstrate the utility of the BPP test for assessing the MGP of drinking water and show the performance limits of biofiltration for MGP reduction. Copyright © 2017 Elsevier Ltd. All rights reserved.

  3. The promise of mixed-methods for advancing latino health research.

    Science.gov (United States)

    Apesoa-Varano, Ester Carolina; Hinton, Ladson

    2013-09-01

    Mixed-methods research in the social sciences has been conducted for quite some time. More recently, mixed-methods have become popular in health research, with the National Institutes of Health leading the impetus to fund studies that implement such an approach. The public health issues facing us today are great and they range from policy and other macro-level issues, to systems level problems to individuals' health behaviors. For Latinos, who are projected to become the largest minority group bearing a great deal of the burden of social inequality in the U.S., it is important to understand the deeply-rooted nature of these health disparities in order to close the gap in health outcomes. Mixed-methodology thus holds promise for advancing research on Latino heath by tackling health disparities from a variety of standpoints and approaches. The aim of this manuscript is to provide two examples of mixed methods research, each of which addresses a health topic of considerable importance to older Latinos and their families. These two examples will illustrate a) the complementary use of qualitative and quantitative methods to advance health of older Latinos in an area that is important from a public health perspective, and b) the "translation" of findings from observational studies (informed by social science and medicine) to the development and testing of interventions.

  4. Application of quantitative real-time PCR compared to filtration methods for the enumeration of Escherichia coli in surface waters within Vietnam.

    Science.gov (United States)

    Vital, Pierangeli G; Van Ha, Nguyen Thi; Tuyet, Le Thi Hong; Widmer, Kenneth W

    2017-02-01

    Surface water samples in Vietnam were collected from the Saigon River, rural and suburban canals, and urban runoff canals in Ho Chi Minh City, Vietnam, and were processed to enumerate Escherichia coli. Quantification was done through membrane filtration and quantitative real-time polymerase chain reaction (PCR). Mean log colony-forming unit (CFU)/100 ml E. coli counts in the dry season for river/suburban canals and urban canals were log 2.8 and 3.7, respectively, using a membrane filtration method, while using Taqman quantitative real-time PCR they were log 2.4 and 2.8 for river/suburban canals and urban canals, respectively. For the wet season, data determined by the membrane filtration method in river/suburban canals and urban canals samples had mean counts of log 3.7 and 4.1, respectively. While mean log CFU/100 ml counts in the wet season using quantitative PCR were log 3 and 2, respectively. Additionally, the urban canal samples were significantly lower than those determined by conventional culture methods for the wet season. These results show that while quantitative real-time PCR can be used to determine levels of fecal indicator bacteria in surface waters, there are some limitations to its application and it may be impacted by sources of runoff based on surveyed samples.

  5. Mainstream Smoke Gas Phase Filtration Performance of Adsorption Materials Evaluated With A Puff-by-Puff Multiplex GC-MS Method

    Directory of Open Access Journals (Sweden)

    Xue L

    2014-12-01

    Full Text Available The mainstream smoke filtration performance of activated carbon, silica gel and polymeric aromatic resins for gas-phase components was evaluated using a puff-by-puff multiplex gas chromatography-mass spectrometry (GC-MS analysis method (1. The sample 1R4F Kentucky reference cigarettes were modified by placing the adsorbents in a plug/space/plug filter configuration. Due to differences in surface area and structural characteristics, the adsorbent materials studied showed different levels of filtration activities for the twenty-six constituents monitored. Activated carbon had significant adsorption activity for all the gas-phase smoke constituents observed except ethane and carbon dioxide, while silica gel had significant activities for polar components such as aldehydes, acrolein, ketones, and diacetyl. XAD-16 polyaromatic resins showed varied levels of activity for aromatic compounds, cyclic dienes and ketones.

  6. Relation Between Filtration and Soil Consolidation Theories

    Directory of Open Access Journals (Sweden)

    Strzelecki Tomasz

    2015-03-01

    Full Text Available This paper presents a different, than commonly used, form of equations describing the filtration of a viscous compressible fluid through a porous medium in isothermal conditions. This mathematical model is compared with the liquid flow equations used in the theory of consolidation. It is shown that the current commonly used filtration model representation significantly differs from the filtration process representation in Biot’s and Terzaghi’s soil consolidation models, which has a bearing on the use of the methods of determining the filtration coefficient on the basis of oedometer test results. The present analysis of the filtration theory equations should help interpret effective parameters of the non-steady filtration model. Moreover, equations for the flow of a gas through a porous medium and an interpretation of the filtration model effective parameters in this case are presented.

  7. Comparison of glomerular filtration rate measured by plasma sample technique, Cockroft Gault method and Gates’ method in voluntary kidney donors and renal transplant recipients

    International Nuclear Information System (INIS)

    Hephzibah, Julie; Shanthly, Nylla; Oommen, Regi

    2013-01-01

    There are numerous methods for calculation of glomerular filtration rate (GFR), which is a crucial measurement to identify patients with renal disease. The aim of this study is to compare four different methods of GFR calculation. Clinical setup, prospective study. Data was collected from routine renal scans done for voluntary kidney donors (VKD) or renal transplant recipients 6 months after transplantation. Following technetium-99m diethylene triamine penta acetic acid injection, venous blood samples were collected from contralateral arm at 120, 180, and 240 min through an indwelling venous cannula and direct collection by syringe. A total volume of 1 ml of plasma from each sample and standards were counted in an automatic gamma counter for 1 min. Blood samples taken at 120 min and 240 min were used for double plasma sample method (DPSM) and a sample taken at 180 min for single plasma sample method (SPSM). Russell's formulae for SPSM and DPSM were used for GFR estimation. Gates’ method GFR was calculated by vendor provided software. Correlation analysis was performed using Pearson's correlation test. SPSM correlated well with DPSM. GFR value in healthy potential kidney donors has a significant role in the selection of donors. The mean GFR ± (standard deviation) in VKD using SPSM, DPSM, camera depth method and Cockroft Gault method was 134.6 (25.9), 137.5 (42.4), 98.6 (15.9), 83.5 (21.1) respectively. Gates’ GFR calculation did not correlate well with plasma sampling method. Calculation of GFR plays a vital role in the management of renal patients, hence it was noted that Gates GFR may not be a reliable method of calculation. SPSM was more reliable. DPSM is reliable but cumbersome. It is difficult to accurately calculate GFR without a gold standard

  8. DEFINITION OF DENSITY OF THE THERMAL STATIONARY STREAMS ON A SURFACES OF A SLEEVE OF CYLINDER COMBUSTION ENGINE BY A METHOD OF OPTIMUM FILTRATION KALMANA

    Directory of Open Access Journals (Sweden)

    ZARENBIN V. G.

    2016-01-01

    Full Text Available Problem statement. At research warmly intensity and thermal weariness of internal combustion engines (ICE the knowledge and the analysis of local temperatures and thermal streams in the basic details forming the chamber of combustion is defining. Theoretically the problem consists in the decision of the equation of heat conductivity at the set features of course of thermal processes on border of bodies. Thus there is a problem of accuracy of the decision since it depends on accuracy of the task of real boundary conditions which can be received only by means of physical experiment and corresponding metrological maintenance. Unlike temperature the thermal stream cannot be measured directly, therefore it define on a difference of temperatures (thermal gradient a method or a calorimetric method. Definition of density of streams with the help as named gauges of a thermal stream when the measured temperatures are used at the decision of a return problem of heat conductivity for chosen thermometric an element is most extended. In this case, except the requirement of one-dimensionality of distribution of temperatures, linearity and the minimum distortion of temperature fields of thermal system, there are considerable difficulties of calculation derivative of the measured temperature. To perspective it is possible to carry methods of researches which it is accepted to name cybernetic diagnostics or identification of systems. Their essence consists that the deformed information on object is compared to its mathematical model and then are defined its condition, parameters or entrance influences by minimization of square-law function are nonviscous. In work definition of density of thermal stationary streams on surfaces of a sleeve of cylinder ICE by a method of optimum filtration Kalmana and also an estimation of their reliability and accuracy is made. Possibility of application of filtration Kalmana is shown at experimental researches in ICE. The purpose

  9. Cross-flow filtration and axial filtration

    International Nuclear Information System (INIS)

    Kraus, K.A.

    1974-01-01

    Two relatively novel alternative solid-liquid-separation techniques of filtration are discussed. In cross-flow filtration, the feed is pumped past the filtering surface. While in axial filtration the filter, mounted on a rotor, is moved with respect to the feed. While large-scale application of the axial filter is still in doubt, it permits with little expenditure of time and money, duplication of many hydrodynamic aspects of cross-flow filtration for fine-particle handling problems. The technique has been applied to municipal wastes, low-level radioactive waste treatment plant, lead removal from industrial wastes, removal of pulp-mill contaminants, textile-mill wastes, and pretreatment of saline waters by lime-soda process in preparation for hyperfiltration. Economics and energy requirements are also discussed

  10. MALDI-TOF identification of Gram-negative bacteria directly from blood culture bottles containing charcoal: Sepsityper® kits versus centrifugation-filtration method.

    Science.gov (United States)

    Riederer, Kathleen; Cruz, Kristian; Shemes, Stephen; Szpunar, Susan; Fishbain, Joel T

    2015-06-01

    Matrix-assisted laser desorption ionization time-of-flight (MALDI-TOF) mass spectrometry has dramatically altered the way microbiology laboratories identify clinical isolates. Direct blood culture (BC) detection may be hampered, however, by the presence of charcoal in BC bottles currently in clinical use. This study evaluates an in-house process for extraction and MALDI-TOF identification of Gram-negative bacteria directly from BC bottles containing charcoal. Three hundred BC aliquots were extracted by a centrifugation-filtration method developed in our research laboratory with the first 96 samples processed in parallel using Sepsityper® kits. Controls were colonies from solid media with standard phenotypic and MALDI-TOF identification. The identification of Gram-negative bacteria was successful more often via the in-house method compared to Sepsityper® kits (94.7% versus 78.1%, P≤0.0001). Our in-house centrifugation-filtration method was further validated for isolation and identification of Gram-negative bacteria (95%; n=300) directly from BC bottles containing charcoal. Copyright © 2015 Elsevier Inc. All rights reserved.

  11. Some observations on air filtration

    NARCIS (Netherlands)

    Kluyver, A.J.; Visser, J.

    1950-01-01

    1. A method has been developed for testing the filtration efficiency of some filter materials. For each of the materials investigated — cotton wool, stillite and carbon — a suitable filter has been devised. 2. The filtered air was analyzed as to its germ content with the aid of a set of 3 capillary

  12. An improved method for purification of recombinant truncated heme oxygenase-1 by expanded bed adsorption and gel filtration.

    Science.gov (United States)

    Hu, Hong-Bo; Wang, Wei; Han, Ling; Zhou, Wen-Pu; Zhang, Xue-Hong

    2007-03-01

    Recombinant truncated human heme oxygenase-1 (hHO-1) expressed in Escherichia coli was efficiently separated and purified from feedstock by DEAE-ion exchange expanded bed adsorption. Protocol optimization of hHO-1 on DEAE adsorbent resulted in adsorption in 0 M NaCl and elution in 150 mM NaCl at a pH of 8.5. The active enzyme fractions separated from the expanded bed column were further purified by a Superdex 75 gel filtration step. The specific hHO-1 activity increased from 0.82 +/- 0.05 to 24.8 +/- 1.8 U/mg during the whole purification steps. The recovery and purification factor of truncated hHO-1 of the whole purification were 72.7 +/- 4.7 and 30.2 +/- 2.3%, respectively. This purification process can decrease the demand on the preparation of feedstock and simplify the purification process.

  13. Determination of chromate ion in drilling mud filtrates

    International Nuclear Information System (INIS)

    Whitfill, D.

    1980-01-01

    A method of determining the amount of chromate ion in an aqueous drilling mud filtrate containing organic color bodies such as lignosulfate wherein the method comprises: (A) treating the aqueous filtrate with an effective amount of hydrogen peroxide to destroy said color bodies, and (B) measuring the amount of chromate ion in the filtrate by means of a spectrophotometer

  14. X-ray computerized tomography based on the method of reciprocal projection with filtration by double differentiation. Procedure and information peculiarities

    International Nuclear Information System (INIS)

    Vajnberg, Eh.I.; Kazak, I.A.; Fajngojz, M.L.

    1985-01-01

    The results of experimental evaluation of procedure and information peculiarities of the method of reciprocal projection with filtration of projections by double differentiation (RPFDD) for the monitoring of industrial products are generalized. Succession of stages n the RPFDD method permits to separately optimize reconstruction of high-frequeny and low-frequency tomogram structure which sharply reduces the acuteness of contradictions of conventional scheme between the required increase of accuracy and intolerable growth of computerized charges. High accuracy of evaluation of the linear attenuation factor of low-frequency structures in a wide range of densities at the last stage of RPFDD scheme is attained despite the non-conventionally small range of values at earlier stages of computerized processing

  15. A new promising screening method for cognitive functioning in elderly patients

    NARCIS (Netherlands)

    Kuin, Y.; Nijsten, J.M.H.; Stok-Koch, E.G.H.J.; Jansen, R.W.M.M.

    1996-01-01

    The Mini Mental State Examination (MMSE) is frequently used as a screening method to detect cognitive dysfunctioning. However, the MMSE has limited sensitivity to detect mild impairment. We aimed to develop a new screening method to discriminate between normal and mild cognitive functioning in older

  16. Analysis of protein carbonylation - pitfalls and promise in commonly used methods

    DEFF Research Database (Denmark)

    Rogowska-Wrzesinska, A.; Wojdyla, K.; Nedic, O.

    2014-01-01

    that research scientists are becoming more eager to be able to measure accurately the level of oxidized protein in biological materials, and to determine the precise site of the oxidative attack on the protein, in order to get insights into the molecular mechanisms involved in the progression of diseases....... Several methods for measuring protein carbonylation have been implemented in different laboratories around the world. However, to date no methods prevail as the most accurate, reliable, and robust. The present paper aims at giving an overview of the common methods used to determine protein carbonylation...... in biological material as well as to highlight the limitations and the potential. The ultimate goal is to give quick tips for a rapid decision making when a method has to be selected and taking into consideration the advantage and drawback of the methods....

  17. Analysis of protein carbonylation-pitfalls and promise in commonly used methods

    DEFF Research Database (Denmark)

    Rogowska-Wrzesinska, Adelina; Wojdyla, K; Nedić, O

    2014-01-01

    that research scientists are becoming more eager to be able to measure accurately the level of oxidized protein in biological materials, and to determine the precise site of the oxidative attack on the protein, in order to get insights into the molecular mechanisms involved in the progression of diseases....... Several methods for measuring protein carbonylation have been implemented in different laboratories around the world. However, to date no methods prevail as the most accurate, reliable, and robust. The present paper aims at giving an overview of the common methods used to determine protein carbonylation...... in biological material as well as to highlight the limitations and the potential. The ultimate goal is to give quick tips for a rapid decision making when a method has to be selected and taking into consideration the advantage and drawback of the methods....

  18. A broken promise: microbiome differential abundance methods do not control the false discovery rate.

    Science.gov (United States)

    Hawinkel, Stijn; Mattiello, Federico; Bijnens, Luc; Thas, Olivier

    2017-08-22

    High-throughput sequencing technologies allow easy characterization of the human microbiome, but the statistical methods to analyze microbiome data are still in their infancy. Differential abundance methods aim at detecting associations between the abundances of bacterial species and subject grouping factors. The results of such methods are important to identify the microbiome as a prognostic or diagnostic biomarker or to demonstrate efficacy of prodrug or antibiotic drugs. Because of a lack of benchmarking studies in the microbiome field, no consensus exists on the performance of the statistical methods. We have compared a large number of popular methods through extensive parametric and nonparametric simulation as well as real data shuffling algorithms. The results are consistent over the different approaches and all point to an alarming excess of false discoveries. This raises great doubts about the reliability of discoveries in past studies and imperils reproducibility of microbiome experiments. To further improve method benchmarking, we introduce a new simulation tool that allows to generate correlated count data following any univariate count distribution; the correlation structure may be inferred from real data. Most simulation studies discard the correlation between species, but our results indicate that this correlation can negatively affect the performance of statistical methods. © The Author 2017. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  19. A Promising New Method to Estimate Drug-Polymer Solubility at Room Temperature

    DEFF Research Database (Denmark)

    Knopp, Matthias Manne; Gannon, Natasha; Porsch, Ilona

    2016-01-01

    The established methods to predict drug-polymer solubility at room temperature either rely on extrapolation over a long temperature range or are limited by the availability of a liquid analogue of the polymer. To overcome these issues, this work investigated a new methodology where the drug-polymer...... solubility is estimated from the solubility of the drug in a solution of the polymer at room temperature using the shake-flask method. Thus, the new polymer in solution method does not rely on temperature extrapolations and only requires the polymer and a solvent, in which the polymer is soluble, that does...... not affect the molecular structure of the drug and polymer relative to that in the solid state. Consequently, as this method has the potential to provide fast and precise estimates of drug-polymer solubility at room temperature, we encourage the scientific community to further investigate this principle both...

  20. Magnetic-seeding filtration

    International Nuclear Information System (INIS)

    Ying, T.Y.; Chin, C.J.; Lu, S.C.; Yiacoumi, S.

    1997-10-01

    Magnetic-seeding filtration consists of two steps: heterogeneous particle flocculation of magnetic and nonmagnetic particles in a stirred tank and high-gradient magnetic filtration (HGMF). The effects of various parameters affecting magnetic-seeding filtration (HGMF). The effects of various parameters affecting magnetic seeding filtration are theoretically and experimentally investigated. A trajectory model that includes hydrodynamic resistance, van der Waals, and electrostatic forces is developed to calculate the flocculation frequency in a turbulent-shear regime. Fractal dimension is introduced to simulate the open structure of aggregates. A magnetic-filtration model that consists of trajectory analysis, a particle build-up model, a breakthrough model, and a bivariate population-balance model is developed to predict the breakthrough curve of magnetic-seeding filtration. A good agreement between modeling results and experimental data is obtained. The results show that the model developed in this study can be used to predict the performance of magnetic-seeding filtration without using empirical coefficients or fitting parameters. 35 refs., 7 figs., 1 tab

  1. Fabrication of Mineralized Collagen from Bovine Waste Materials by Hydrothermal Method as Promised Biomaterials

    DEFF Research Database (Denmark)

    Sheikh, Faheem A.; Kanjwal, Muzafar Ahmed; Macossay, Javier

    2011-01-01

    In the present study, we aimed to produce mineralized-collagen by hydrothermal process. A simple method not depending on additional foreign chemicals has been employed to isolate the mineralized-collagen fibers from bovine waste. The process of extraction involves the use of hydrothermal method...... mineral content in the individual fibers. The X-ray diffraction showed the crystalline feature of the obtained nano-compounds. The thermo gravimetric analysis was used to differentiate between the collagen and mineral parts of obtained product. Overall, the results generously indicated production of well...

  2. Soil Scientific Research Methods Used in Archaeology – Promising Soil Biochemistry: a Mini-review

    Directory of Open Access Journals (Sweden)

    Valerie Vranová

    2015-01-01

    Full Text Available This work seeks to review soil scientific methods that have been used and are still being used in archaeology. This review paper aims at emphasising the importance of soil science practice to archaeology thus adding a scientific analytical nature to the cultural nature of archaeology. Common methods (physical, chemical and biochemical used to analyse archaeological soils and artefacts is touched on and their strengths and shortcomings duly noted to become the base for future research. Furthermore, the authors made emphasis on distinctive excavating/sampling methods, biochemical analyses focused on distinctive features of plough-land and soil organic matter mineralization, Counter Immunoelectrophoresis (CEIP method by the presence of proteins testing, carbon analyses such as carbon-14 dating techniques, soil phosphorus studies and geochemical analyses of hematite Fe2O3 and cinnabaryte HgS contents. It is obvious that, the future of archaeology is in the soil because the soil harbours information of the past hence the synergy between soil and archaeological research has to be strengthened and archaeology made a prime agenda by soil scientists by expanding the analyses scope of total phosphorus extraction and giving attention to soil magnetism.

  3. SAAS: Short Amino Acid Sequence - A Promising Protein Secondary Structure Prediction Method of Single Sequence

    Directory of Open Access Journals (Sweden)

    Zhou Yuan Wu

    2013-07-01

    Full Text Available In statistical methods of predicting protein secondary structure, many researchers focus on single amino acid frequencies in α-helices, β-sheets, and so on, or the impact near amino acids on an amino acid forming a secondary structure. But the paper considers a short sequence of amino acids (3, 4, 5 or 6 amino acids as integer, and statistics short sequence's probability forming secondary structure. Also, many researchers select low homologous sequences as statistical database. But this paper select whole PDB database. In this paper we propose a strategy to predict protein secondary structure using simple statistical method. Numerical computation shows that, short amino acids sequence as integer to statistics, which can easy see trend of short sequence forming secondary structure, and it will work well to select large statistical database (whole PDB database without considering homologous, and Q3 accuracy is ca. 74% using this paper proposed simple statistical method, but accuracy of others statistical methods is less than 70%.

  4. Concept mapping as a promising method to bring practice into science

    NARCIS (Netherlands)

    van Bon, M.J.H.; van de Goor, L.A.M.; Holsappel, J.C.; Kuunders, T.J.M.; Jacobs-van der Bruggen, M.A.M.; te Brake, J.H.M.; van Oers, J.A.M.

    2014-01-01

    Objective Concept mapping is a method for developing a conceptual framework of a complex topic for use as a guide to evaluation or planning. In concept mapping, thoughts and ideas are represented in the form of a picture or map, the content of which is determined by a group of stakeholders. This

  5. Retrospective study of renal distribution volume with DTPA-99mTc: performance of single plasma method for glomerular filtration rate estimation

    International Nuclear Information System (INIS)

    Legendre, J.M.; Cledes, J.; Morin, J.F.; Morin, P.P.

    1997-01-01

    169 glomerular filtration rate (GFR) measurements, performed in clinical practice, were analysed for estimation of GFR by several common methods. In one half of patients, we observed that early (2-3-4 hours) and tardive (3-4-5 hours three point plasma methods were highly correlated, r = 0,998 (n = 82). Even if regression line significantly differed from identify, differences between methods were low (-6, 1 to + 4,4 mL/min/1,73 m 2 ). Method with urinary collection was also correlated to plasma methods (r = 0,920 in both cases). Plasma based mean values were higher than that for urinary by 3,6 mL/min/1,73 m 2 (2-3-4 hours) and 3, 1 (3-4-5 hours). Using plasma GFR values and distribution volume, linear and quadratic regressions were tested for GFR = f (V) and GFR = f (In (V). The lowest observed standard deviation (3,6 mL/min; n = 82) was for GFR 234 = f (V 4h ) using a quadratic equation. This was applied to the second patient group for GFR estimation with 4 hours single point plasma method. Estimations were compared to GFR plasma values. For comparison, GFR estimations were also obtained using the Christensen's equation. (authors)

  6. Troubling objectivity: the promises and pitfalls of training Haitian clinicians in qualitative research methods.H.

    Science.gov (United States)

    Minn, Pierre

    2015-01-01

    Building research capacity is a central component of many contemporary global health programs and partnerships. While medical anthropologists have been conducting qualitative research in resource-poor settings for decades, they are increasingly called on to train "local" clinicians, researchers, and students in qualitative research methods. In this article, I describe the process of teaching introductory courses in qualitative research methods to Haitian clinicians, hospital staff, and medical students, who rarely encounter qualitative research in their training or practice. These trainings allow participants to identify and begin to address challenges related to health services delivery, quality of care, and provider-patient relations. However, they also run the risk of perpetuating colonial legacies of objectification and reinforcing hierarchies of knowledge and knowledge production. As these trainings increase in number and scope, they offer the opportunity to reflect critically on new forms of transnational interventions that aim to reduce health disparities.

  7. Promising ethical arguments for product differentiation in the organic food sector. A mixed methods research approach

    OpenAIRE

    Zander, Katrin; Stolz, Hanna; Hamm, Ulrich

    2013-01-01

    Ethical consumerism is a growing trend worldwide. Ethical consumers’ expectations are increasing and neither the Fairtrade nor the organic farming concept covers all the ethical concerns of consumers. Against this background the aim of this research is to elicit consumers’ preferences regarding organic food with additional ethical attributes and their relevance at the market place. A mixed methods research approach was applied by combining an Information Display Matrix, Focus Group Discuss...

  8. Study on the Matching Relationship between Polymer Hydrodynamic Characteristic Size and Pore Throat Radius of Target Block S Based on the Microporous Membrane Filtration Method

    Directory of Open Access Journals (Sweden)

    Li Yiqiang

    2014-01-01

    Full Text Available The concept of the hydrodynamic characteristic size of polymer was proposed in this study, to characterize the size of aggregates of many polymer molecules in the polymer percolation process. The hydrodynamic characteristic sizes of polymers used in the target block S were examined by employing microporous membrane filtration method, and the factors were studied. Natural core flow experiments were conducted in order to set up the flow matching relationship plate. According to the flow matching plate, the relationship between the hydrodynamic characteristic size of polymer and pore throat radius obtained from core mercury injection data was found. And several suitable polymers for different reservoirs permeability were given. The experimental results of microporous membrane filtration indicated that the hydrodynamic characteristic size of polymer maintained a good nonlinear relationship with polymer viscosity; the value increased as the molecular weight and concentration of the polymer increased and increased as the salinity of dilution water decreased. Additionally, the hydrodynamic characteristic size decreased as the pressure increased, so the hydrodynamic characteristic size ought to be determined based on the pressure of the target block. In the core flow studies, good matching of polymer and formation was identified as polymer flow pressure gradient lower than the fracture pressure gradient of formation. In this case, good matching that was the pore throat radius should be larger than 10 times the hydrodynamic characteristic size of polymer in this study. Using relationship, more matching relationship between the hydrodynamic characteristic sizes of polymer solutions and the pore throat radius of target block was determined.

  9. Promising ethical arguments for product differentiation in the organic food sector. A mixed methods research approach.

    Science.gov (United States)

    Zander, Katrin; Stolz, Hanna; Hamm, Ulrich

    2013-03-01

    Ethical consumerism is a growing trend worldwide. Ethical consumers' expectations are increasing and neither the Fairtrade nor the organic farming concept covers all the ethical concerns of consumers. Against this background the aim of this research is to elicit consumers' preferences regarding organic food with additional ethical attributes and their relevance at the market place. A mixed methods research approach was applied by combining an Information Display Matrix, Focus Group Discussions and Choice Experiments in five European countries. According to the results of the Information Display Matrix, 'higher animal welfare', 'local production' and 'fair producer prices' were preferred in all countries. These three attributes were discussed with Focus Groups in depth, using rather emotive ways of labelling. While the ranking of the attributes was the same, the emotive way of communicating these attributes was, for the most part, disliked by participants. The same attributes were then used in Choice Experiments, but with completely revised communication arguments. According to the results of the Focus Groups, the arguments were presented in a factual manner, using short and concise statements. In this research step, consumers in all countries except Austria gave priority to 'local production'. 'Higher animal welfare' and 'fair producer prices' turned out to be relevant for buying decisions only in Germany and Switzerland. According to our results, there is substantial potential for product differentiation in the organic sector through making use of production standards that exceed existing minimum regulations. The combination of different research methods in a mixed methods approach proved to be very helpful. The results of earlier research steps provided the basis from which to learn - findings could be applied in subsequent steps, and used to adjust and deepen the research design. Copyright © 2012 Elsevier Ltd. All rights reserved.

  10. Lactic Acid Fermentation, Urea and Lime Addition: Promising Faecal Sludge Sanitizing Methods for Emergency Sanitation.

    Science.gov (United States)

    Anderson, Catherine; Malambo, Dennis Hanjalika; Perez, Maria Eliette Gonzalez; Nobela, Happiness Ngwanamoseka; de Pooter, Lobke; Spit, Jan; Hooijmans, Christine Maria; de Vossenberg, Jack van; Greya, Wilson; Thole, Bernard; van Lier, Jules B; Brdjanovic, Damir

    2015-10-29

    In this research, three faecal sludge sanitizing methods-lactic acid fermentation, urea treatment and lime treatment-were studied for application in emergency situations. These methods were investigated by undertaking small scale field trials with pit latrine sludge in Blantyre, Malawi. Hydrated lime was able to reduce the E. coli count in the sludge to below the detectable limit within 1 h applying a pH > 11 (using a dosage from 7% to 17% w/w, depending faecal sludge alkalinity), urea treatment required about 4 days using 2.5% wet weight urea addition, and lactic acid fermentation needed approximately 1 week after being dosed with 10% wet weight molasses (2 g (glucose/fructose)/kg) and 10% wet weight pre-culture (99.8% pasteurised whole milk and 0.02% fermented milk drink containing Lactobacillus casei Shirota). Based on Malawian prices, the cost of sanitizing 1 m³ of faecal sludge was estimated to be €32 for lactic acid fermentation, €20 for urea treatment and €12 for hydrated lime treatment.

  11. Spatial capture-recapture: a promising method for analyzing data collected using artificial cover objects

    Science.gov (United States)

    Sutherland, Chris; Munoz, David; Miller, David A.W.; Grant, Evan H. Campbell

    2016-01-01

    Spatial capture–recapture (SCR) is a relatively recent development in ecological statistics that provides a spatial context for estimating abundance and space use patterns, and improves inference about absolute population density. SCR has been applied to individual encounter data collected noninvasively using methods such as camera traps, hair snares, and scat surveys. Despite the widespread use of capture-based surveys to monitor amphibians and reptiles, there are few applications of SCR in the herpetological literature. We demonstrate the utility of the application of SCR for studies of reptiles and amphibians by analyzing capture–recapture data from Red-Backed Salamanders, Plethodon cinereus, collected using artificial cover boards. Using SCR to analyze spatial encounter histories of marked individuals, we found evidence that density differed little among four sites within the same forest (on average, 1.59 salamanders/m2) and that salamander detection probability peaked in early October (Julian day 278) reflecting expected surface activity patterns of the species. The spatial scale of detectability, a measure of space use, indicates that the home range size for this population of Red-Backed Salamanders in autumn was 16.89 m2. Surveying reptiles and amphibians using artificial cover boards regularly generates spatial encounter history data of known individuals, which can readily be analyzed using SCR methods, providing estimates of absolute density and inference about the spatial scale of habitat use.

  12. Chemical vapour deposition - a promising method for production of different kinds of carbon nanotubes

    Energy Technology Data Exchange (ETDEWEB)

    Leonhardt, A.; Ritschel, M.; Bartsch, K.; Graff, A.; Taeschner, C.; Fink, J. [Institut fuer Festkoerper- und Werkstofforschung Dresden e.V. (Germany)

    2001-08-01

    Carbon nanostructures (fibres, multi and single walled tubes) have been synthesized by catalytic chemical vapour deposition. The catalyst material, deposition temperature and the used hydrocarbon are the main parameters responsible for the formation of the desired structure. In dependence on these parameters and by optimising the deposition process nanofibres with herringbone structure and tubular multiwalled nanotubes were deposited in large amounts and high purity. In the case of single wall nanotubes synthesis an aftertreatment and process is absolutely necessary to obtain material with high percentage of tubes. Layers of disordered and aligned multiwalled nanotubes were deposited on oxidised silicon substrates coated with thin sputtered metal layers (Co, permalloy) by using the micro-wave assisted plasma CVD process or the bias supported hot filament CVD method. The latter method allows relatively low deposition temperatures (550 - 750 C). The obtained carbon modifications were characterised by scanning and transmission electron microscopy. Furthermore, the electron field emission of the CNT's layers were investigated. (orig.)

  13. PROBLEMS OF NONSTATIONARY FILTRATION

    Directory of Open Access Journals (Sweden)

    Vsevolod A. Shabanov

    2018-03-01

    Full Text Available he article deals with the classical hydrodynamic theory of filtration. Discusses models of soil, fluid and nature of fluid flow that formed the basis for the creation of the classic filtration theory. Also discusses the assumptions made for the linearization of the equations. Evaluated the scope of the classical filtration theory. Proposed a new model of filtration through a porous medium, based on the application of the laws of theoretical mechanics. It is based on the classical model of soil: the soil is composed of capillaries with ..parallel axes, in which the liquid moves. For tasks of infiltration equations of motion. Considered special cases of unsteady motion of a finite volume of liquid. Numerical example a machine experiment.

  14. Filtration in Porous Media

    DEFF Research Database (Denmark)

    Yuan, Hao; Shapiro, Alexander

    There is a considerable and ongoing effort aimed at understanding the transport and the deposition of suspended particles in porous media, especially non-Fickian transport and non-exponential deposition of particles. In this work, the influential parameters in filtration models are studied...... to understand their effects on the non-Fickian transport and the non-exponential deposition. The filtration models are validated by the comparisons between the modelling results and the experimental data.The elliptic equation with distributed filtration coefficients may be applied to model non-Fickian transport...... and hyperexponential deposition. The filtration model accounting for the migration of surface associated particles may be applied for non-monotonic deposition....

  15. Fuzzy promises

    DEFF Research Database (Denmark)

    Anker, Thomas Boysen; Kappel, Klemens; Eadie, Douglas

    2012-01-01

    as narrative material to communicate self-identity. Finally, (c) we propose that brands deliver fuzzy experiential promises through effectively motivating consumers to adopt and play a social role implicitly suggested and facilitated by the brand. A promise is an inherently ethical concept and the article...... concludes with an in-depth discussion of fuzzy brand promises as two-way ethical commitments that put requirements on both brands and consumers....

  16. Water Filtration Products

    Science.gov (United States)

    1986-01-01

    American Water Corporation manufactures water filtration products which incorporate technology originally developed for manned space operations. The formula involves granular activated charcoal and other ingredients, and removes substances by catalytic reactions, mechanical filtration, and absorption. Details are proprietary. A NASA literature search contributed to development of the compound. The technology is being extended to a deodorizing compound called Biofresh which traps gas and moisture inside the unit. Further applications are anticipated.

  17. Ultrasonic Nebulizer Assisted LIBS: a Promising Metal Elements Detection Method for Aqueous Sample Analysis

    International Nuclear Information System (INIS)

    Zhong Shilei; Zheng Ronger; Lu Yuan; Cheng Kai; Xiu Junshan

    2015-01-01

    A newly developed approach for trace metal elements detection for aqueous samples analysis is presented in this paper. The idea of this approach is to improve ablation efficiency by transforming the liquid sample into a dense cloud of droplets using an ultrasonic nebulizer. The resulting droplets are then subjected to analysis by laser induced breakdown spectroscopy (LIBS). A purpose-built ultrasonic nebulizer assisted LIBS (UN-LIBS) system has been applied to the analysis of aqueous samples at trace levels of concentration. Experimental investigations of solution samples were carried out with various dissolved trace metal elements (Mn, Zn, Cu, Pb, Fe, Mg and Na) using this approach. The characteristics of UN-LIBS signal of the elements were investigated regarding the lifetime and S/B ratio and the calibration curves for trace metal elements analyses. The obtained LODs are comparable or much better than the LODS of the reported signal enhancement approaches when the laser pulse energy was as low as 30 mJ. The good linearity of calibration curves and the low LODs shows the potential ability of this method for metal elements analysis application. The density of the electrons was calculated by measuring the Stark width of the line of H α . The possible mechanism of the LIBS signal enhancement of this approach was briefly discussed. (paper)

  18. Diagnosing developmental dyscalculia on the basis of reliable single case FMRI methods: promises and limitations.

    Directory of Open Access Journals (Sweden)

    Philipp Johannes Dinkel

    representation in fronto-parietal cortex. We conclude that dyscalculic children show large individual differences in brain activation patterns. Nonetheless, the majority of dyscalculic children can be differentiated from controls employing brain activation patterns when appropriate methods are used.

  19. Diagnosing developmental dyscalculia on the basis of reliable single case FMRI methods: promises and limitations.

    Science.gov (United States)

    Dinkel, Philipp Johannes; Willmes, Klaus; Krinzinger, Helga; Konrad, Kerstin; Koten, Jan Willem

    2013-01-01

    fronto-parietal cortex. We conclude that dyscalculic children show large individual differences in brain activation patterns. Nonetheless, the majority of dyscalculic children can be differentiated from controls employing brain activation patterns when appropriate methods are used.

  20. Measurement of glomerular filtration rate (GFR) with 99mTc-DTPA and semiconductors minidetectors: further validation of the method

    International Nuclear Information System (INIS)

    Mahlstedt, J.; Muehlbauer, J.; Schrott, K.H.; Wolf, F.

    1982-01-01

    A technique measuring external radiation with semiconductor minidetectors (SCM) by use of a portable solid state memory after bolus injection of 1mCi 99mTc-DTPA is described. The correlation of the calculated clearances to plasma creatinine levels and to endogenous creatinine clearance as well is satisfactory. This new technique is compared with a standard steady state technique (GFR-SS) using 51 Cr-EDTA. GFR-SCM is strongly correlated to GFR-SS as standard method, therefore the data provides substantial evidence that GFR-SCM is a reliable method of GFR measurement. The advantages are: fast availability of the test result especially when calculated by use of a minicomputer; ease of performance in routine work; convenience for the patient without need of compliance and low costs for the detector system

  1. Are vacuum-filtrated reduced graphene oxide membranes symmetric?

    KAUST Repository

    Tang, Bo

    2015-12-02

    Graphene or reduced graphene oxide (rGO) membrane-based materials are promising for many advanced applications due to their exceptional properties. One of the most widely used synthesis methods for rGO membranes is vacuum filtration of graphene oxide (GO) on a filter membrane, followed by reduction, which shows great advantages such as operational convenience and good controllability. Despite vacuum-filtrated rGO membranes being widely used in many applications, a fundamental question is overlooked: are the top and bottom surfaces of the membranes formed at the interfaces with air and with the filter membrane respectively symmetric or asymmetric? This work, for the first time, reports the asymmetry of the vacuum-filtrated rGO membranes and discloses the filter membranes’ physical imprint on the bottom surface of the rGO membrane, which takes place when the filter membrane surface pores have similar dimension to GO sheets. This result points out that the asymmetric surface properties should be cautiously taken into consideration while designing the surface-related applications for GO and rGO membranes.

  2. Are vacuum-filtrated reduced graphene oxide membranes symmetric?

    KAUST Repository

    Tang, Bo; Zhang, Lianbin; Li, Renyuan; Wu, Jinbo; Hedhili, Mohamed Neijib; Wang, Peng

    2015-01-01

    Graphene or reduced graphene oxide (rGO) membrane-based materials are promising for many advanced applications due to their exceptional properties. One of the most widely used synthesis methods for rGO membranes is vacuum filtration of graphene oxide (GO) on a filter membrane, followed by reduction, which shows great advantages such as operational convenience and good controllability. Despite vacuum-filtrated rGO membranes being widely used in many applications, a fundamental question is overlooked: are the top and bottom surfaces of the membranes formed at the interfaces with air and with the filter membrane respectively symmetric or asymmetric? This work, for the first time, reports the asymmetry of the vacuum-filtrated rGO membranes and discloses the filter membranes’ physical imprint on the bottom surface of the rGO membrane, which takes place when the filter membrane surface pores have similar dimension to GO sheets. This result points out that the asymmetric surface properties should be cautiously taken into consideration while designing the surface-related applications for GO and rGO membranes.

  3. Estimating Glomerular Filtration Rate in Older People

    Directory of Open Access Journals (Sweden)

    Sabrina Garasto

    2014-01-01

    Full Text Available We aimed at reviewing age-related changes in kidney structure and function, methods for estimating kidney function, and impact of reduced kidney function on geriatric outcomes, as well as the reliability and applicability of equations for estimating glomerular filtration rate (eGFR in older patients. CKD is associated with different comorbidities and adverse outcomes such as disability and premature death in older populations. Creatinine clearance and other methods for estimating kidney function are not easy to apply in older subjects. Thus, an accurate and reliable method for calculating eGFR would be highly desirable for early detection and management of CKD in this vulnerable population. Equations based on serum creatinine, age, race, and gender have been widely used. However, these equations have their own limitations, and no equation seems better than the other ones in older people. New equations specifically developed for use in older populations, especially those based on serum cystatin C, hold promises. However, further studies are needed to definitely accept them as the reference method to estimate kidney function in older patients in the clinical setting.

  4. Evaluation of 99Tcm-DTPA glomerular filtration rate by the Gates method in patients with type 2 diabetes

    International Nuclear Information System (INIS)

    Yuan Jie; Zhang Guangming; Liu Congjin; Wang Yuankai; Zhu Huiqing; Kuai Dayu; Wu Xia; Hu Renming; Liu Xingdang

    2013-01-01

    Objective: To study the changes of GFR measured in different time intervals after the injection of 99 Tc m -DTPA and to evaluate the clinical value of GFR in patients with type 2 diabetes. Methods: Eleven healthy volunteers (6 males, 5 females; mean age (61.45±7.90) years, age range: 47-79 years) and 56 patients with type 2 diabetes (31 males, 25 females; mean age (60.98±6.96) years, age range: 45-75 years) were recruited. 99 Tc m -DTPA was used to measure GFR for all subjects. ROI was drawn at 2 and 3 min post-injection and GFR was calculated by Gates method. Two-sample t test and Pearson correlation analysis were performed with SPSS 15.0. Results: SCr ((84.90±14.38) μmol/L) was significantly correlated with GFR in patients with type 2 diabetes. There was negative correlation between SCr and GFR for both, left and right kidneys at 3 min post-injection (r=-0.652, -0.636, -0.470, all P≤0.001) and at 2 min post-injection (r=-0.599, -0.553, -0.529, all P<0.001). Total GFR, GFR for left kidney and GFR for right kidney at 3 min post-injection in diabetes group ((69.77 ± 11.00),(33.12 ± 5.74), (37.34 ± 9.81) ml/min) were lower than those in control group ((97.89±5.98), (46.60±4.91), (51.28±4.20) ml/min; t=-8.212, -7.233, -4.069, all P<0.001). Conclusions: To calculate the GFR of the patients with type 2 diabetes, 3 min post-injection is the optimal time. Measurement of GFR by 99 Tc m -DTPA is useful in early diagnosis of diabetic nephropathy. (authors)

  5. Binary conductive network for construction of Si/Ag nanowires/rGO integrated composite film by vacuum-filtration method and their application for lithium ion batteries

    International Nuclear Information System (INIS)

    Tang, H.; Xia, X.H.; Zhang, Y.J.; Tong, Y.Y.; Wang, X.L.; Gu, C.D.; Tu, J.P.

    2015-01-01

    Construction of high-capacity anode is highly important for the development of next-generation high-performance lithium ion batteries (LIBs). Herein we fabricate Si/Ag nanowires/reduced graphene oxide (Si/Ag NWs/rGO) integrated composite film by introducing binary conductive networks (Ag NWs and rGO) into Si active materials with the help of a facile vacuum-filtration method. Active Si nanoparticles are homogeneously encapsulated by binary Ag NWs-rGO conductive network, in which Ag NWs are interwoven among the rGO sheets. The electrochemical properties of the integrated Si/Ag NWs/rGO composite film are thoroughly characterized as anode of LIBs. Compared to the Si/rGO composite film, the integrated Si/Ag NWs/rGO composite film exhibits enhanced electrochemical performances with higher capacity, better high-rate capability and cycling stability (1269 mAh g"−"1 at 50 mA g"−"1 up to 50 cycles). The binary conductive network plays a positive role in the enhancement of performance due to its faster ion/electron transfer, and better anti-structure degradation caused by volume expansion during the cycling process.

  6. Filtration by eyelashes

    Science.gov (United States)

    Vistarakula, Krishna; Bergin, Mike; Hu, David

    2010-11-01

    Nearly every mammalian and avian eye is rimmed with lashes. We investigate experimentally the ability of lashes to reduce airborne particle deposition in the eye. We hypothesize that there is an optimum eyelash length that maximizes both filtration ability and extent of peripheral vision. This hypothesis is tested using a dual approach. Using preserved heads from 36 species of animals at the American Museum of Natural History, we determine the relationship between eye size and eyelash geometry (length and spacing). We test the filtration efficacy of these geometries by deploying outdoor manikins and measuring particle deposition rate as a function of eyelash length.

  7. Magnetic-seeding filtration

    International Nuclear Information System (INIS)

    Depaoli, D.

    1996-01-01

    This task will investigate the capabilities of magnetic-seeding filtration for the enhanced removal of magnetic and nonmagnetic particulates from liquids. This technology appies to a wide range of liquid wastes, including groundwater, process waters, and tank supernatant. Magnetic-seeding filtration can be used in several aspects of treatment, such as (1) removal of solids, particularly those in the colloidal-size range that are difficult to remove by conventional means; (2) removal of contaminants by precipitation processes; and (3) removal of contaminants by sorption processes

  8. {sup 90}Y microspheres prepared by sol-gel method, promising medical material for radioembolization of liver malignancies

    Energy Technology Data Exchange (ETDEWEB)

    Łada, Wiesława, E-mail: w.lada@ichtj.waw.pl [Institute of Nuclear Chemistry and Technology, 03-195 Warsaw, Dorodna 16 (Poland); Iller, Edward [National Centre for Nuclear Research, Radioisotope Centre POLATOM, 05-400 Otwock, Andrzej Sołtan 7 (Poland); Wawszczak, Danuta [Institute of Nuclear Chemistry and Technology, 03-195 Warsaw, Dorodna 16 (Poland); Konior, Marcin, E-mail: marcin.konior@polatom.pl [National Centre for Nuclear Research, Radioisotope Centre POLATOM, 05-400 Otwock, Andrzej Sołtan 7 (Poland); Dziel, Tomasz [National Centre for Nuclear Research, Radioisotope Centre POLATOM, 05-400 Otwock, Andrzej Sołtan 7 (Poland)

    2016-10-01

    A new technology for the production of radiopharmaceutical {sup 90}Y microspheres in the form of spherical yttrium oxide grains obtained by sol-gel method has been described. The authors present and discuss the results of investigations performed in the development of new production technology of yttrium microspheres and determination of their physic-chemical properties. The final product has the structure of spherical yttrium oxide grains with a diameter 25–100 μm, is stable and free from contaminants. Irradiation of 20 mg samples of grains with diameter of 20–50 μm in the thermal neutron flux of 1.7 × 10{sup 14} cm{sup −2} s{sup −1} at the core of MARIA research nuclear reactor allowed to obtain microspheres labelled with the {sup 90}Y isotope on the way of the nuclear reaction {sup 89}Y(n, γ){sup 90}Y. Specific activity of irradiated microspheres has been determined by application of absolute triple to double coincidence ratio method (TDCR) and has been evaluated at 190 MBq/mg Y. {sup 90}Y microspheres prepared by the proposed technique can be regarded as a promising medical material for radioembolization of liver malignancies. - Highlights: • Sol-gel methods for preparation of spherical yttrium trioxide grains have been proposed. • Determination condition for irradiation {sup 89}Y{sub 2}O{sub 3} grains in nuclear reactor • Evaluation of specific activity of {sup 90}Y microspheres • Estimation of {sup 90}Y microspheres as promising medical material for radioembolization.

  9. Impact of urine concentration adjustment method on associations between urine metals and estimated glomerular filtration rates (eGFR) in adolescents

    Energy Technology Data Exchange (ETDEWEB)

    Weaver, Virginia M., E-mail: vweaver@jhsph.edu [Department of Environmental Health Sciences, Johns Hopkins Bloomberg School of Public Health, Johns Hopkins University, Baltimore, MD (United States); Johns Hopkins University School of Medicine, Baltimore, MD (United States); Welch Center for Prevention, Epidemiology, and Clinical Research, Johns Hopkins Bloomberg School of Public Health, Johns Hopkins University, Baltimore, MD (United States); Vargas, Gonzalo García [Faculty of Medicine, University of Juárez of Durango State, Durango (Mexico); Secretaría de Salud del Estado de Coahuila, Coahuila, México (Mexico); Silbergeld, Ellen K. [Department of Environmental Health Sciences, Johns Hopkins Bloomberg School of Public Health, Johns Hopkins University, Baltimore, MD (United States); Rothenberg, Stephen J. [Instituto Nacional de Salud Publica, Centro de Investigacion en Salud Poblacional, Cuernavaca, Morelos (Mexico); Fadrowski, Jeffrey J. [Johns Hopkins University School of Medicine, Baltimore, MD (United States); Welch Center for Prevention, Epidemiology, and Clinical Research, Johns Hopkins Bloomberg School of Public Health, Johns Hopkins University, Baltimore, MD (United States); Rubio-Andrade, Marisela [Faculty of Medicine, University of Juárez of Durango State, Durango (Mexico); Parsons, Patrick J. [Laboratory of Inorganic and Nuclear Chemistry, Wadsworth Center, New York State Department of Health, Albany, NY (United States); Department of Environmental Health Sciences, School of Public Health, University at Albany, Albany, NY (United States); Steuerwald, Amy J. [Laboratory of Inorganic and Nuclear Chemistry, Wadsworth Center, New York State Department of Health, Albany, NY (United States); and others

    2014-07-15

    Positive associations between urine toxicant levels and measures of glomerular filtration rate (GFR) have been reported recently in a range of populations. The explanation for these associations, in a direction opposite that of traditional nephrotoxicity, is uncertain. Variation in associations by urine concentration adjustment approach has also been observed. Associations of urine cadmium, thallium and uranium in models of serum creatinine- and cystatin-C-based estimated GFR (eGFR) were examined using multiple linear regression in a cross-sectional study of adolescents residing near a lead smelter complex. Urine concentration adjustment approaches compared included urine creatinine, urine osmolality and no adjustment. Median age, blood lead and urine cadmium, thallium and uranium were 13.9 years, 4.0 μg/dL, 0.22, 0.27 and 0.04 g/g creatinine, respectively, in 512 adolescents. Urine cadmium and thallium were positively associated with serum creatinine-based eGFR only when urine creatinine was used to adjust for urine concentration (β coefficient=3.1 mL/min/1.73 m{sup 2}; 95% confidence interval=1.4, 4.8 per each doubling of urine cadmium). Weaker positive associations, also only with urine creatinine adjustment, were observed between these metals and serum cystatin-C-based eGFR and between urine uranium and serum creatinine-based eGFR. Additional research using non-creatinine-based methods of adjustment for urine concentration is necessary. - Highlights: • Positive associations between urine metals and creatinine-based eGFR are unexpected. • Optimal approach to urine concentration adjustment for urine biomarkers uncertain. • We compared urine concentration adjustment methods. • Positive associations observed only with urine creatinine adjustment. • Additional research using non-creatinine-based methods of adjustment needed.

  10. Impact of urine concentration adjustment method on associations between urine metals and estimated glomerular filtration rates (eGFR) in adolescents

    International Nuclear Information System (INIS)

    Weaver, Virginia M.; Vargas, Gonzalo García; Silbergeld, Ellen K.; Rothenberg, Stephen J.; Fadrowski, Jeffrey J.; Rubio-Andrade, Marisela; Parsons, Patrick J.; Steuerwald, Amy J.

    2014-01-01

    Positive associations between urine toxicant levels and measures of glomerular filtration rate (GFR) have been reported recently in a range of populations. The explanation for these associations, in a direction opposite that of traditional nephrotoxicity, is uncertain. Variation in associations by urine concentration adjustment approach has also been observed. Associations of urine cadmium, thallium and uranium in models of serum creatinine- and cystatin-C-based estimated GFR (eGFR) were examined using multiple linear regression in a cross-sectional study of adolescents residing near a lead smelter complex. Urine concentration adjustment approaches compared included urine creatinine, urine osmolality and no adjustment. Median age, blood lead and urine cadmium, thallium and uranium were 13.9 years, 4.0 μg/dL, 0.22, 0.27 and 0.04 g/g creatinine, respectively, in 512 adolescents. Urine cadmium and thallium were positively associated with serum creatinine-based eGFR only when urine creatinine was used to adjust for urine concentration (β coefficient=3.1 mL/min/1.73 m 2 ; 95% confidence interval=1.4, 4.8 per each doubling of urine cadmium). Weaker positive associations, also only with urine creatinine adjustment, were observed between these metals and serum cystatin-C-based eGFR and between urine uranium and serum creatinine-based eGFR. Additional research using non-creatinine-based methods of adjustment for urine concentration is necessary. - Highlights: • Positive associations between urine metals and creatinine-based eGFR are unexpected. • Optimal approach to urine concentration adjustment for urine biomarkers uncertain. • We compared urine concentration adjustment methods. • Positive associations observed only with urine creatinine adjustment. • Additional research using non-creatinine-based methods of adjustment needed

  11. Standoff Methods for the Detection of Threat Agents: A Review of Several Promising Laser-Based Techniques

    Directory of Open Access Journals (Sweden)

    J. Bruce Johnson

    2014-01-01

    Full Text Available Detection of explosives, explosive precursors, or other threat agents presents a number of technological challenges for optical sensing methods. Certainly detecting trace levels of threat agents against a complex background is chief among these challenges; however, the related issues of multiple target distances (from standoff to proximity and sampling time scales (from passive mines to rapid rate of march convoy protection for different applications make it unlikely that a single technique will be ideal for all sensing situations. A number of methods for spanning the range of optical sensor technologies exist which, when integrated, could produce a fused sensor system possessing a high level of sensitivity to threat agents and a moderate standoff real-time capability appropriate for portal screening of personnel or vehicles. In this work, we focus on several promising, and potentially synergistic, laser-based methods for sensing threat agents. For each method, we have briefly outlined the technique and report on the current level of capability.

  12. Filtration approach to mitigate indoor Thoron progeny concentration

    International Nuclear Information System (INIS)

    Wang, J.; Meisenberg, O.; Karg, E.; Tschiersch, J.; Chen, Y.

    2010-01-01

    This study investigates filtration of air as potential mitigation method of thoron progeny exposure. The experiments were conducted in a model room (volume 7.1 m 3 ) which was equipped with a pump and an HEPA (high efficiency particulate air) filter. Filtration at a rate of 0.2, 0.4, 0.5 and 0.8 h -1 during 88 h proved an effective practice in reducing the total indoor thoron decay product concentration. The results indicate that 0.4-0.8 h -1 filtration rate had almost the same filtration efficiency in decreasing the total thoron EEC (equilibrium equivalent concentration) by 97% while 80% of total thoron EEC were reduced by 0.2 h -1 filtration rate; meanwhile, the unattached thoron EEC rose significantly by 190, 270, 290%, respectively under 0.4-0.8 h -1 filtration rate, whereas 0.2 h -1 filtration rate increased unattached thoron EEC by 40%. The aerosol number size distribution variation reveals that filtration operation removes smaller particles faster or earlier than the larger ones. The annual effective dose calculated was reduced by 91-92% at a filtration rate of 0.4-0.8 h -1 while 75% reduced at 0.2 h -1 filtration rate after 88 h filtration process. (authors)

  13. Water Treatment Technology - Filtration.

    Science.gov (United States)

    Ross-Harrington, Melinda; Kincaid, G. David

    One of twelve water treatment technology units, this student manual on filtration provides instructional materials for six competencies. (The twelve units are designed for a continuing education training course for public water supply operators.) The competencies focus on the following areas: purposes of sedimentation basins and flocculation…

  14. Retrospective study of renal distribution volume with DTPA-{sup 99m}Tc: performance of single plasma method for glomerular filtration rate estimation; Etude retrospective du volume de distribution du traceur renal DTPA-{sup 99m}Tc: performance d`une methode a un prelevement sanguin pour l`estimation du debit de filtration glomerulaire

    Energy Technology Data Exchange (ETDEWEB)

    Legendre, J.M.; Cledes, J.; Morin, J.F.; Morin, P.P. [Centre Hospitalier Regional Augustin-Morvan, 29 - Brest (France)

    1997-08-01

    169 glomerular filtration rate (GFR) measurements, performed in clinical practice, were analysed for estimation of GFR by several common methods. In one half of patients, we observed that early (2-3-4 hours) and tardive (3-4-5 hours) three point plasma methods were highly correlated, r = 0,998 (n = 82). Even if regression line significantly differed from identify, differences between methods were low (-6, 1 to + 4,4 mL/min/1,73 m{sup 2}). Method with urinary collection was also correlated to plasma methods (r = 0,920 in both cases). Plasma based mean values were higher than that for urinary by 3,6 mL/min/1,73 m{sup 2} (2-3-4 hours) and 3, 1 (3-4-5 hours). Using plasma GFR values and distribution volume, linear and quadratic regressions were tested for GFR = f (V) and GFR = f (In (V)). The lowest observed standard deviation (3,6 mL/min; n = 82) was for GFR{sub 234} = f (V{sub 4h}) using a quadratic equation. This was applied to the second patient group for GFR estimation with 4 hours single point plasma method. Estimations were compared to GFR plasma values. For comparison, GFR estimations were also obtained using the Christensen`s equation. (authors). 17 refs.

  15. Facility of aerosol filtration

    Energy Technology Data Exchange (ETDEWEB)

    Duverger de Cuy, G; Regnier, J

    1975-04-18

    Said invention relates to a facility of aerosol filtration, particularly of sodium aerosols. Said facility is of special interest for fast reactors where sodium fires involve the possibility of high concentrations of sodium aerosols which soon clog up conventional filters. The facility intended for continuous operation, includes at the pre-filtering stage, means for increasing the size of the aerosol particles and separating clustered particles (cyclone separator).

  16. Mixture based outlier filtration

    Czech Academy of Sciences Publication Activity Database

    Pecherková, Pavla; Nagy, Ivan

    2006-01-01

    Roč. 46, č. 2 (2006), s. 30-35 ISSN 1210-2709 R&D Projects: GA MŠk 1M0572; GA MDS 1F43A/003/120 Institutional research plan: CEZ:AV0Z10750506 Keywords : data filtration * system modelling * mixture models Subject RIV: BD - Theory of Information http://library.utia.cas.cz/prace/20060165.pdf

  17. Detergent zeolite filtration plant

    OpenAIRE

    Stanković Mirjana S.; Pezo Lato L.

    2003-01-01

    The IGPC Engineering Department designed basic projects for detergent zeolite filtration plant, using technology developed in the IGPC laboratories. Several projects were completed: technological, machine, electrical, automation. On the basis of these projects, a production plant with a capacity of 75,000 t/y was manufactured, at "Zeolite Mira", Mira (VE), Italy, in 1997, for increasing detergent zeolite production, from 50,000 to 100,000 t/y. The main goal was to increase the detergent zeoli...

  18. Determination of the best method to estimate glomerular filtration rate from serum creatinine in adult patients with sickle cell disease: a prospective observational cohort study

    Directory of Open Access Journals (Sweden)

    Arlet Jean-Benoît

    2012-08-01

    Full Text Available Abstract Background Sickle cell disease (SCD leads to tissue hypoxia resulting in chronic organ dysfunction including SCD associated nephropathy. The goal of our study was to determine the best equation to estimate glomerular filtration rate (GFR in SCD adult patients. Methods We conducted a prospective observational cohort study. Since 2007, all adult SCD patients in steady state, followed in two medical departments, have had their GFR measured using iohexol plasma clearance (gold standard. The Cockcroft-Gault, MDRD-v4, CKP-EPI and finally, MDRD and CKD-EPI equations without adjustment for ethnicity were tested to estimate GFR from serum creatinine. Estimated GFRs were compared to measured GFRs according to the graphical Bland and Altman method. Results Sixty-four SCD patients (16 men, median age 27.5 years [range 18.0-67.5], 41 with SS-genotype were studied. They were Sub-Saharan Africa and French West Indies natives and predominantly lean (median body mass index: 22 kg/m2 [16-33]. Hyperfiltration (defined as measured GFR >110 mL/min/1.73 m2 was detected in 53.1% of patients. Urinary albumin/creatinine ratio was higher in patients with hyperfiltration than in patients with normal GFR (4.05 mg/mmol [0.14-60] versus 0.4 mg/mmol [0.7-81], p = 0.01. The CKD-EPI equation without adjustment for ethnicity had both the lowest bias and the greatest precision. Differences between estimated GFRs using the CKP-EPI equation and measured GFRs decreased with increasing GFR values, whereas it increased with the Cockcroft-Gault and MDRD-v4 equations. Conclusions We confirm that SCD patients have a high rate of glomerular hyperfiltration, which is frequently associated with microalbuminuria or macroalbuminuria. In non-Afro-American SCD patients, the best method for estimating GFR from serum creatinine is the CKD-EPI equation without adjustment for ethnicity. This equation is particularly accurate to estimate high GFR values, including glomerular

  19. Filtration of polydispersed colloids

    International Nuclear Information System (INIS)

    Nuttall, H.E.

    1988-01-01

    In this study, the dynamic microscopic form of the population balance model is applied to the problem of polydispersed particle capture in one spatial diffusion. This mathematical modeling approach can be applied to the difficult and potentially important problem of particulate (radiocolloid) transport in the groundwater surrounding a nuclear waste disposal site. To demonstrate the population balance methodology, the equations were developed and used to investigate transport and capture of polydispersed colloids in packed columns. Modeling simulations were compared to experimental column data. The multidimensional form of the population balance equation was used to analyze the transport and capture of polydispersed colloids. A numerical model was developed to describe transport of polydispersed colloids through a one-dimensional porous region. The effects of various size distributions were investigated in terms of capture efficiency. For simulating the column data, it was found by trial and error that as part of the population balance model a linear size dependent filtration function gave a good fit to the measured colloid concentration profile. The effects of constant versus size dependent filtration coefficients were compared and the differences illustrated by the calculated colloid profile within the column. Also observed from the model calculations was the dramatically changing liquid-phase colloid-size distribution which was plotted as a function of position down the column. This modeling approach was excellent for describing and understanding microscopic filtration in porous media

  20. Filter aids influence on pressure drop across a filtration system

    Science.gov (United States)

    Hajar, S.; Rashid, M.; Nurnadia, A.; Ammar, M. R.; Hasfalina, C. M.

    2017-06-01

    Filter aids is commonly used to reduce pressure drop across air filtration system as it helps to increase the efficiency of filtration of accumulated filter cake. Filtration velocity is one of the main parameters that affect the performance of filter aids material. In this study, a formulated filter aids consisting of PreKot™ and activated carbon mixture (designated as PrekotAC) was tested on PTFE filter media under various filtration velocities of 5, 6, and 8 m/min at a constant material loading of 0.2 mg/mm2. Results showed that pressure drop is highly influenced by filtration velocity where higher filtration velocity leads to a higher pressure drop across the filter cake. It was found that PrekotAC performed better in terms of reducing the pressure drop across the filter cake even at the highest filtration velocity. The diversity in different particle size distribution of non-uniform particle size in the formulated PrekotAC mixture presents a higher permeability causes a lower pressure drop across the accumulated filter cake. The finding suggests that PrekotAC is a promising filter aids material that helps reducing the pressure drop across fabric filtration system.

  1. Purification of contaminated water by filtration through porous glass

    Science.gov (United States)

    Wydeven, T.; Leban, M. I.

    1972-01-01

    Method for purifying water that is contaminated with mineral salts and soluble organic compounds is described. Method consists of high pressure filtration of contaminated water through stabilized porous glass membranes. Procedure for conducting filtration is described. Types of materials by percentage amounts removed from the water are identified.

  2. 99mTc-thymine scintigraphy may be a promising method in the diagnosis of breast cancer

    International Nuclear Information System (INIS)

    Ribeiro, Monica Pires; Souza, Sergio Augusto Lopes de; Lopes, Flavia Paiva Proenca Lobo; Rosado-de-Castro, Paulo Henrique; Fonseca, Lea Mirian Barbosa da; Gutfilen, Bianca

    2013-01-01

    Objective: Mammography has been established as the gold standard for the detection of breast cancer, and imaging techniques such as ultrasonography, magnetic resonance imaging, scintigraphy and positron emission tomography may be useful to improve its sensitivity and specificity. The objective of this study with breast scintigraphy was to evaluate the uptake of 99m Tc-thymine in mammary lesions. Methods: A total of 45 patients were included in this study. Thirty-three patients (73%) were subjected to surgery or percutaneous biopsy, providing histopathological data. The other 12 patients who remained under surveillance received clinical examinations and biannual mammography with a normal follow-up of at least three years, the data from which were used for comparison with the scintimammography results. Results: The majority of patients (64.4%) had clinically impalpable lesions with a mammogram diagnosis of microcalcifications, impalpable nodules, or focal asymmetry. Of the studied lesions, 87% were smaller or equal to 20 mm in diameter, and 22% had malignant histopathological findings. Scintigraphy with 99m Tc-thymine had a sensitivity of 70%, a specificity of 85.7%, positive and negative predictive values of 58.3% and 90.9%, respectively, and an accuracy of 82.2%. Conclusions: The results of this study are consistent with those previously reported by other authors. The good specificity and high negative predictive value of this technique and the absence of uptake in the heart indicate that it may be a promising complementary method in clinical practice and that it may contribute to reducing unnecessary benign biopsies. (author)

  3. 99mTc-thymine scintigraphy may be a promising method in the diagnosis of breast cancer

    Directory of Open Access Journals (Sweden)

    Monica Pires Ribeiro

    2013-01-01

    Full Text Available OBJECTIVE: Mammography has been established as the gold standard for the detection of breast cancer, and imaging techniques such as ultrasonography, magnetic resonance imaging, scintigraphy and positron emission tomography may be useful to improve its sensitivity and specificity. The objective of this study with breast scintigraphy was to evaluate the uptake of 99mTc-thymine in mammary lesions. METHODS: A total of 45 patients were included in this study. Thirty-three patients (73% were subjected to surgery or percutaneous biopsy, providing histopathological data. The other 12 patients who remained under surveillance received clinical examinations and biannual mammography with a normal follow-up of at least three years, the data from which were used for comparison with the scintimammography results. RESULTS: The majority of patients (64.4% had clinically impalpable lesions with a mammogram diagnosis of microcalcifications, impalpable nodules, or focal asymmetry. Of the studied lesions, 87% were smaller or equal to 20 mm in diameter, and 22% had malignant histopathological findings. Scintigraphy with 99mTc-thymine had a sensitivity of 70%, a specificity of 85.7%, positive and negative predictive values of 58.3% and 90.9%, respectively, and an accuracy of 82.2%. CONCLUSIONS: The results of this study are consistent with those previously reported by other authors. The good specificity and high negative predictive value of this technique and the absence of uptake in the heart indicate that it may be a promising complementary method in clinical practice and that it may contribute to reducing unnecessary benign biopsies.

  4. 99mTc-thymine scintigraphy may be a promising method in the diagnosis of breast cancer

    Energy Technology Data Exchange (ETDEWEB)

    Ribeiro, Monica Pires; Souza, Sergio Augusto Lopes de; Lopes, Flavia Paiva Proenca Lobo; Rosado-de-Castro, Paulo Henrique; Fonseca, Lea Mirian Barbosa da; Gutfilen, Bianca [Universidade Federal do Rio de Janeiro (UFRJ), RJ (Brazil). Faculdade de Medicina. Hospital Universitario Clementino Fraga Filho, Departamento de Radiologia

    2013-05-01

    Objective: Mammography has been established as the gold standard for the detection of breast cancer, and imaging techniques such as ultrasonography, magnetic resonance imaging, scintigraphy and positron emission tomography may be useful to improve its sensitivity and specificity. The objective of this study with breast scintigraphy was to evaluate the uptake of {sup 99m}Tc-thymine in mammary lesions. Methods: A total of 45 patients were included in this study. Thirty-three patients (73%) were subjected to surgery or percutaneous biopsy, providing histopathological data. The other 12 patients who remained under surveillance received clinical examinations and biannual mammography with a normal follow-up of at least three years, the data from which were used for comparison with the scintimammography results. Results: The majority of patients (64.4%) had clinically impalpable lesions with a mammogram diagnosis of microcalcifications, impalpable nodules, or focal asymmetry. Of the studied lesions, 87% were smaller or equal to 20 mm in diameter, and 22% had malignant histopathological findings. Scintigraphy with {sup 99m}Tc-thymine had a sensitivity of 70%, a specificity of 85.7%, positive and negative predictive values of 58.3% and 90.9%, respectively, and an accuracy of 82.2%. Conclusions: The results of this study are consistent with those previously reported by other authors. The good specificity and high negative predictive value of this technique and the absence of uptake in the heart indicate that it may be a promising complementary method in clinical practice and that it may contribute to reducing unnecessary benign biopsies. (author)

  5. Industrial investigations of the liquid steel filtration

    Directory of Open Access Journals (Sweden)

    K. Janiszewski

    2014-07-01

    Full Text Available Hitherto existing investigations concerning the ceramic filter use in the steel making processes have given good results. The obtained results of filtration have proved that this method may be used as an effective and cheap way of steel filtration from non-metallic inclusions. Placing filters in the tundish is the best location considering the limitation of the possibility of secondary pollution of steel. Yet, the results presented in this paper, of an experiment prepared and carried out in the industrial environment, are the only positive results obtained, which are connected with so much quantities of liquid steel processed with use of the multi-hole ceramic filters.

  6. BWR condensate filtration studies

    International Nuclear Information System (INIS)

    Wilson, J.A.; Pasricha, A.; Rekart, T.E.

    1993-09-01

    Poor removal of particulate corrosion products (especially iron) from condensate is one of the major problems in BWR systems. The presence of activated corrosion products creates ''hot spots'' and increases piping dose rates. Also, fuel efficiency is reduced and the risk of fuel failure is increased by the deposit of corrosion products on the fuel. Because of these concerns, current EPRI guidelines call for a maximum of 2 ppb of iron in the reactor feedwater with a level of 0.5 ppb being especially desirable. It has become clear that conventional deep bed resins are incapable of meeting these levels. While installation of prefilter systems is an option, it would be more economical for plants with naked deep beds to find an improved bead resin for use in existing systems. BWR condensate filtration technologies are being tested on a condensate side stream at Hope Creek Nuclear Generating Station. After two years of testing, hollow fiber filters (HFF) and fiber matrix filters (FMF), and low crosslink cation resin, all provide acceptable results. The results are presented for pressure drop, filtration efficiency, and water quality measurements. The costs are compared for backwashable non-precoat HFF and FMF. Results are also presented for full deep bed vessel tests of the low crosslink cation resin

  7. Magnetic-seeding filtration

    Energy Technology Data Exchange (ETDEWEB)

    DePaoli, D.W.; Tsouris, C. [Oak Ridge National Lab., TN (United States); Yiacoumi, Sotira

    1997-10-01

    Magnetic-seeding filtration is a technology under development for the enhanced removal of magnetic and non-magnetic particulates from liquids. This process involves the addition of a small amount of magnetic seed particles (such as naturally occurring iron oxide) to a waste suspension, followed by treatment with a magnetic filter. Non-magnetic and weakly magnetic particles are made to undergo nonhomogeneous flocculation with the seed particles, forming flocs of high magnetic susceptibility that are readily removed by a conventional high-gradient magnetic filter. This technology is applicable to a wide range of liquid wastes, including groundwater, process waters, and tank supernatants. Magnetic-seeding filtration may be used in several aspects of treatment, such as (1) removal of solids, particularly those in the colloidal size range that are difficult to remove by conventional means; (2) removal of contaminants by precipitation processes; and (3) removal of contaminants by sorption processes. Waste stream characteristics for which the technology may be applicable include (1) particle sizes ranging from relatively coarse (several microns) to colloidal particles, (2) high or low radiation levels, (3) broad-ranging flow rates, (4) low to moderate solids concentration, (5) cases requiring high decontamination factors, and (6) aqueous or non-aqueous liquids. At this point, the technology is at the bench-scale stage of development; laboratory studies and fundamental modeling are currently being employed to determine the capabilities of the process.

  8. Magnetic-seeding filtration

    International Nuclear Information System (INIS)

    DePaoli, D.W.; Tsouris, C.; Yiacoumi, Sotira.

    1997-01-01

    Magnetic-seeding filtration is a technology under development for the enhanced removal of magnetic and non-magnetic particulates from liquids. This process involves the addition of a small amount of magnetic seed particles (such as naturally occurring iron oxide) to a waste suspension, followed by treatment with a magnetic filter. Non-magnetic and weakly magnetic particles are made to undergo nonhomogeneous flocculation with the seed particles, forming flocs of high magnetic susceptibility that are readily removed by a conventional high-gradient magnetic filter. This technology is applicable to a wide range of liquid wastes, including groundwater, process waters, and tank supernatants. Magnetic-seeding filtration may be used in several aspects of treatment, such as (1) removal of solids, particularly those in the colloidal size range that are difficult to remove by conventional means; (2) removal of contaminants by precipitation processes; and (3) removal of contaminants by sorption processes. Waste stream characteristics for which the technology may be applicable include (1) particle sizes ranging from relatively coarse (several microns) to colloidal particles, (2) high or low radiation levels, (3) broad-ranging flow rates, (4) low to moderate solids concentration, (5) cases requiring high decontamination factors, and (6) aqueous or non-aqueous liquids. At this point, the technology is at the bench-scale stage of development; laboratory studies and fundamental modeling are currently being employed to determine the capabilities of the process

  9. Health Benefits of Particle Filtration

    OpenAIRE

    Fisk, William J.

    2013-01-01

    The evidence of health benefits of particle filtration in homes and commercial buildings is reviewed. Prior reviews of papers published before 2000 are summarized. The results of 16 more recent intervention studies are compiled and analyzed. Also reviewed are four studies that modeled health benefits of using filtration to reduce indoor exposures to particles from outdoors. Prior reviews generally concluded that particle filtration is, at best, a source of small improvements in allergy and as...

  10. Dynamic optimization of dead-end membrane filtration

    NARCIS (Netherlands)

    Blankert, B.; Betlem, Bernardus H.L.; Roffel, B.; Marquardt, Wolfgang; Pantelides, Costas

    2006-01-01

    An operating strategy aimed at minimizing the energy consumption during the filtration phase of dead-end membrane filtration has been formulated. A method allowing fast calculation of trajectories is used to allow incorporation in a hierarchical optimization scheme. The optimal trajectory can be

  11. Immobilized Filters for Air Filtration

    National Research Council Canada - National Science Library

    Mahle, John J; Zaiee, Saeed

    2002-01-01

    ... (settling performance) and attrition resistance. The fabricated filter samples will be analyzed in order to determine the physical and chemical factors affecting mechanical strength and chemical filtration...

  12. Hot filtration 2

    International Nuclear Information System (INIS)

    Jimenez Rebagliati, Raul; Liberman, S.J.

    1982-01-01

    The magnetic filtration technique allows the removal of suspended magnetic species from a fluid at high flow rate and temperature. It is specially advantageous for water purification in systems such as thermonuclear and thermoelectric plants in which corrosion products must be removed from the heat transport and cooling circuits. Using diluted aqueous suspensions of magnetite, the behaviour of a ball matrix filter was studied as a function of flow rate, temperature and concentration of particles. The retention efficiency shows an exponential decay with fluid's velocity and viscosity in agreement with theory. Within the range of concentration considered, there is no change in the retention with concentration. Design parameters for filters according to plant's needs are obtained from the results of this study. (Author) [es

  13. Functional principal component analysis of glomerular filtration rate curves after kidney transplant.

    Science.gov (United States)

    Dong, Jianghu J; Wang, Liangliang; Gill, Jagbir; Cao, Jiguo

    2017-01-01

    This article is motivated by some longitudinal clinical data of kidney transplant recipients, where kidney function progression is recorded as the estimated glomerular filtration rates at multiple time points post kidney transplantation. We propose to use the functional principal component analysis method to explore the major source of variations of glomerular filtration rate curves. We find that the estimated functional principal component scores can be used to cluster glomerular filtration rate curves. Ordering functional principal component scores can detect abnormal glomerular filtration rate curves. Finally, functional principal component analysis can effectively estimate missing glomerular filtration rate values and predict future glomerular filtration rate values.

  14. Correlation of the glomerular filtration rate by the Gates scintigraphy method and by the creatinine purification in urine of 24 hours

    International Nuclear Information System (INIS)

    Gomez A, E.

    2003-01-01

    The kidney is an important organ that makes that exist equilibrium inside the organism. In it' s multiple functions, one that interests us to know is the glomerular filtration rate (GFR). To know this, exist laboratory and scintigraphy studies like the scintigraphy with technique of Gates and the creatinine purification in urine of 24 hours. The files of 44 patients were studied, which were clinically candidates to kidney donors healthy (25 women and 19 men) with ages that varied from the 18 years to the 54 years ( 35.1 years), with a weight of 43 kilograms to 94 kilograms (68.95 Kg) and with a corporal surface of 1.29 to 2.08 m 2 (1.70 m 2 ). These patients underwent study protocols with creatinine purification and with renal scintigraphy. The glomerular filtration rate obtained by creatinine purification varied from 51.9 ml/min. to 156 ml/min. and the GFR obtained by scintigraphy varied from 3.6 ml/min. to 155.2 ml/min. Once obtained the gathering of data the test of Student was applied to compare the averages of both distributions and the analysis of lineal regression to determine the coefficients of correlation of the complete group. (Author)

  15. Air filtration in HVAC systems

    CERN Document Server

    Ginestet, Alain; Tronville, Paolo; Hyttinen, Marko

    2010-01-01

    Air filtration Guidebook will help the designer and user to understand the background and criteria for air filtration, how to select air filters and avoid problems associated with hygienic and other conditions at operation of air filters. The selection of air filters is based on external conditions such as levels of existing pollutants, indoor air quality and energy efficiency requirements.

  16. 40 CFR 141.173 - Filtration.

    Science.gov (United States)

    2010-07-01

    ... PRIMARY DRINKING WATER REGULATIONS Enhanced Filtration and Disinfection-Systems Serving 10,000 or More People § 141.173 Filtration. A public water system subject to the requirements of this subpart that does... treatment, direct filtration, slow sand filtration, or diatomaceous earth filtration. A public water system...

  17. Diesel fuel filtration system

    International Nuclear Information System (INIS)

    Schneider, D.

    1996-01-01

    The American nuclear utility industry is subject to tight regulations on the quality of diesel fuel that is stored at nuclear generating stations. This fuel is required to supply safety-related emergency diesel generators--the backup power systems associated with the safe shutdown of reactors. One important parameter being regulated is the level of particulate contamination in the diesel fuel. Carbon particulate is a natural byproduct of aging diesel fuel. Carbon particulate precipitates from the fuel's hydrocarbons, then remains suspended or settles to the bottom of fuel oil storage tanks. If the carbon particulate is not removed, unacceptable levels of particulate contamination will eventually occur. The oil must be discarded or filtered. Having an outside contractor come to the plant to filter the diesel fuel can be costly and time consuming. Time is an even more critical factor if a nuclear plant is in a Limiting Condition of Operation (LCO) situation. A most effective way to reduce both cost and risk is for a utility to build and install its own diesel fuel filtration system. The cost savings associated with designing, fabricating and operating the system inhouse can be significant, and the value of reducing the risk of reactor shutdown because of uncertified diesel fuel may be even higher. This article describes such a fuel filtering system

  18. MATHEMATIC MODEL OF ELECTROMAGNETIC FILTRATION PROCESS OF TECHNOLOGICAL LIQUID AND GAS

    OpenAIRE

    R. A. Мouradova

    2005-01-01

    Electromagnetic filtration as a perspective method of filtration and purification of liquid and gas finds its wide application in oil and chemical industry. However absence of highly-reliable model of calculation that permits unambiguously main operational parameters of electromagnetic filtration and limits its wide application. 

  19. Filtration characteristics in membrane bioreactors

    NARCIS (Netherlands)

    Evenblij, H.

    2006-01-01

    Causes of and remedies for membrane fouling in Membrane Bioreactors for wastewater treatment are only poorly understood and described in scientific literature. A Filtration Characterisation Installation and a measurement protocol were developed with the aim of a) unequivocally determination and

  20. Latest aspects of mechanical filtration

    Directory of Open Access Journals (Sweden)

    Stanislav Koláček

    2013-01-01

    Full Text Available The aim of this study was to describe and unify all knowledge about mechanic filtration. The first part deals with the parameters and properties of filtration. Here some important basic concepts are explained such as pressure gradient, filter life, etc. There’s also a description of convenient filtration technology for coarse and fine materials, such as sand, smoke or soot. The second part primarily focuses on the real use and application of filters for liquid and gaseous media. The differences in construction between different types of filters for filtration of fuels, oils, hydraulic fluids, air and cabin filters are described. The last section is focused mainly on new materials for the production of filters. These materials are ceramic or nanomaterials, which can actually be enriched for example with antibacterial silver or some fungicides.

  1. Health benefits of particle filtration.

    Science.gov (United States)

    Fisk, W J

    2013-10-01

    The evidence of health benefits of particle filtration in homes and commercial buildings is reviewed. Prior reviews of papers published before 2000 are summarized. The results of 16 more recent intervention studies are compiled and analyzed. Also, reviewed are four studies that modeled health benefits of using filtration to reduce indoor exposures to particles from outdoors. Prior reviews generally concluded that particle filtration is, at best, a source of small improvements in allergy and asthma health effects; however, many early studies had weak designs. A majority of recent intervention studies employed strong designs and more of these studies report statistically significant improvements in health symptoms or objective health outcomes, particularly for subjects with allergies or asthma. The percentage improvement in health outcomes is typically modest, for example, 7% to 25%. Delivery of filtered air to the breathing zone of sleeping allergic or asthmatic persons may be more consistently effective in improving health than room air filtration. Notable are two studies that report statistically significant improvements, with filtration, in markers that predict future adverse coronary events. From modeling, the largest potential benefits of indoor particle filtration may be reductions in morbidity and mortality from reducing indoor exposures to particles from outdoor air. Published 2013. This article is a US Government work and is in the public domain in the USA.

  2. Health Benefits of Particle Filtration

    Energy Technology Data Exchange (ETDEWEB)

    Fisk, William J.

    2013-10-01

    The evidence of health benefits of particle filtration in homes and commercial buildings is reviewed. Prior reviews of papers published before 2000 are summarized. The results of 16 more recent intervention studies are compiled and analyzed. Also, reviewed are four studies that modeled health benefits of using filtration to reduce indoor exposures to particles from outdoors. Prior reviews generally concluded that particle filtration is, at best, a source of small improvements in allergy and asthma health effects; however, many early studies had weak designs. A majority of recent intervention studies employed strong designs and more of these studies report statistically significant improvements in health symptoms or objective health outcomes, particularly for subjects with allergies or asthma. The percent age improvement in health outcomes is typically modest, for example, 7percent to 25percent. Delivery of filtered air to the breathing zone of sleeping allergic or asthmatic persons may be more consistently effective in improving health than room air filtration. Notable are two studies that report statistically significant improvements, with filtration, in markers that predict future adverse coronary events. From modeling, the largest potential benefits of indoor particle filtration may be reductions in morbidity and mortality from reducing indoor exposures to particles from outdoor air.

  3. Health Benefits of Particle Filtration

    Energy Technology Data Exchange (ETDEWEB)

    Fisk, William J.

    2013-10-01

    The evidence of health benefits of particle filtration in homes and commercial buildings is reviewed. Prior reviews of papers published before 2000 are summarized. The results of 16 more recent intervention studies are compiled and analyzed. Also reviewed are four studies that modeled health benefits of using filtration to reduce indoor exposures to particles from outdoors. Prior reviews generally concluded that particle filtration is, at best, a source of small improvements in allergy and asthma health effects; however, many early studies had weak designs. A majority of recent intervention studies employed strong designs and more of these studies report statistically significant improvements in health symptoms or objective health outcomes, particularly for subjects with allergies or asthma. The percentage improvement in health outcomes is typically modest, e.g., 7percent to 25percent. Delivery of filtered air to the breathing zone of sleeping allergic or asthmatic persons may be more consistently effective in improving health than room air filtration. Notable are two studies that report statistically significant improvements, with filtration, in markers that predict future adverse coronary events. From modeling, the largest potential benefits of indoor particle filtration may be reductions in morbidity and mortality from reducing indoor exposures to particles from outdoor air.

  4. Horizontal-belt filtration at Randfontein Estates Mine

    International Nuclear Information System (INIS)

    Blendulf, K.A.G.; Everett, D.J.

    1979-01-01

    The paper describes tests on horizontal-belt filters for the filtration of gold and uranium. The promising results led to the installation of 17 such filters (ten of them 120 m 2 in size) in the mine's metallurgical plants, and their operation is discussed. Although several problems were encountered both in operation and maintenance, it is concluded that, with correct operation and suitable filter cloths, exceptionally good metallurgical recoveries can be achieved at filtration rates twice to three times higher than those on rotary filters [af

  5. Same day identification and full panel antimicrobial susceptibility testing of bacteria from positive blood culture bottles made possible by a combined lysis-filtration method with MALDI-TOF VITEK mass spectrometry and the VITEK2 system.

    Directory of Open Access Journals (Sweden)

    Alexandra Machen

    Full Text Available Rapid identification and antimicrobial susceptibility testing of microorganisms causing bloodstream infections or sepsis have the potential to improve patient care. This proof-of-principle study evaluates the Lysis-Filtration Method for identification as well as antimicrobial susceptibility testing of bacteria directly from positive blood culture bottles in a clinical setting. A total of 100 non-duplicated positive blood cultures were tested and 1012 microorganism-antimicrobial combinations were assessed. An aliquot of non-charcoal blood culture broth was incubated with lysis buffer briefly before being filtered and washed. Microorganisms recovered from the filter membrane were first identified by using Matrix-Assisted Laser Desorption/Ionization Time-of-Flight VITEK® Mass Spectrometry (VITEK MS. After quick identification from VITEK MS, filtered microorganisms were inoculated to VITEK®2 system for full panel antimicrobial susceptibility testing analysis. Of 100 bottles tested, the VITEK MS resulted in 94.0% correct organism identification to the species level. Compared to the conventional antimicrobial susceptibility testing methods, direct antimicrobial susceptibility testing from VITEK®2 resulted in 93.5% (946/1012 category agreement of antimicrobials tested, with 3.6% (36/1012 minor error, 1.7% (7/1012 major error, and 1.3% (13/1012 very major error of antimicrobials. The average time to identification and antimicrobial susceptibility testing was 11.4 hours by using the Lysis-Filtration method for both VITEK MS and VITEK®2 compared to 56.3 hours by using conventional methods (p<0.00001. Thus, the same-day results of microorganism identification and antimicrobial susceptibility testing directly from positive blood culture can be achieved and can be used for appropriate antibiotic therapy and antibiotic stewardship.

  6. Same Day Identification and Full Panel Antimicrobial Susceptibility Testing of Bacteria from Positive Blood Culture Bottles Made Possible by a Combined Lysis-Filtration Method with MALDI-TOF VITEK Mass Spectrometry and the VITEK2 System

    Science.gov (United States)

    Machen, Alexandra; Drake, Tim; Wang, Yun F. (Wayne)

    2014-01-01

    Rapid identification and antimicrobial susceptibility testing of microorganisms causing bloodstream infections or sepsis have the potential to improve patient care. This proof-of-principle study evaluates the Lysis-Filtration Method for identification as well as antimicrobial susceptibility testing of bacteria directly from positive blood culture bottles in a clinical setting. A total of 100 non-duplicated positive blood cultures were tested and 1012 microorganism-antimicrobial combinations were assessed. An aliquot of non-charcoal blood culture broth was incubated with lysis buffer briefly before being filtered and washed. Microorganisms recovered from the filter membrane were first identified by using Matrix-Assisted Laser Desorption/Ionization Time-of-Flight VITEK® Mass Spectrometry (VITEK MS). After quick identification from VITEK MS, filtered microorganisms were inoculated to VITEK®2 system for full panel antimicrobial susceptibility testing analysis. Of 100 bottles tested, the VITEK MS resulted in 94.0% correct organism identification to the species level. Compared to the conventional antimicrobial susceptibility testing methods, direct antimicrobial susceptibility testing from VITEK®2 resulted in 93.5% (946/1012) category agreement of antimicrobials tested, with 3.6% (36/1012) minor error, 1.7% (7/1012) major error, and 1.3% (13/1012) very major error of antimicrobials. The average time to identification and antimicrobial susceptibility testing was 11.4 hours by using the Lysis-Filtration method for both VITEK MS and VITEK®2 compared to 56.3 hours by using conventional methods (p<0.00001). Thus, the same-day results of microorganism identification and antimicrobial susceptibility testing directly from positive blood culture can be achieved and can be used for appropriate antibiotic therapy and antibiotic stewardship. PMID:24551067

  7. Same day identification and full panel antimicrobial susceptibility testing of bacteria from positive blood culture bottles made possible by a combined lysis-filtration method with MALDI-TOF VITEK mass spectrometry and the VITEK2 system.

    Science.gov (United States)

    Machen, Alexandra; Drake, Tim; Wang, Yun F Wayne

    2014-01-01

    Rapid identification and antimicrobial susceptibility testing of microorganisms causing bloodstream infections or sepsis have the potential to improve patient care. This proof-of-principle study evaluates the Lysis-Filtration Method for identification as well as antimicrobial susceptibility testing of bacteria directly from positive blood culture bottles in a clinical setting. A total of 100 non-duplicated positive blood cultures were tested and 1012 microorganism-antimicrobial combinations were assessed. An aliquot of non-charcoal blood culture broth was incubated with lysis buffer briefly before being filtered and washed. Microorganisms recovered from the filter membrane were first identified by using Matrix-Assisted Laser Desorption/Ionization Time-of-Flight VITEK® Mass Spectrometry (VITEK MS). After quick identification from VITEK MS, filtered microorganisms were inoculated to VITEK®2 system for full panel antimicrobial susceptibility testing analysis. Of 100 bottles tested, the VITEK MS resulted in 94.0% correct organism identification to the species level. Compared to the conventional antimicrobial susceptibility testing methods, direct antimicrobial susceptibility testing from VITEK®2 resulted in 93.5% (946/1012) category agreement of antimicrobials tested, with 3.6% (36/1012) minor error, 1.7% (7/1012) major error, and 1.3% (13/1012) very major error of antimicrobials. The average time to identification and antimicrobial susceptibility testing was 11.4 hours by using the Lysis-Filtration method for both VITEK MS and VITEK®2 compared to 56.3 hours by using conventional methods (pdirectly from positive blood culture can be achieved and can be used for appropriate antibiotic therapy and antibiotic stewardship.

  8. Challenges of Membrane Filtration for Produced Water Treatment in Offshore Oil & Gas Production

    DEFF Research Database (Denmark)

    Jepsen, Kasper Lund; Hansen, Leif; Mai, Christian

    2016-01-01

    struggling to their fundamental limit, therefore the membrane filtration technology turns to be a potential candidate for zero pollutant discharge. Membrane filtration technology suffers from the notorious fouling problem, where many methods for fouling prevention and removal are explored, the general idea...... is to guarantee that a relatively high permeability can be kept during filtration. Another crucial issue using membrane filtration technology is its huge energy consumption, for which there is little research has been done so far to systematically investigate and optimize the filtration system’s energy efficiency...

  9. Cardiac chamber volumes by echocardiography using a new mathematical method: A promising technique for zero-G use

    Science.gov (United States)

    Buckey, J. C.; Beattie, J. M.; Gaffney, F. A.; Nixon, J. V.; Blomqvist, C. G.

    1984-01-01

    Accurate, reproducible, and non-invasive means for ventricular volume determination are needed for evaluating cardiovascular function zero-gravity. Current echocardiographic methods, particularly for the right ventricle, suffer from a large standard error. A new mathematical approach, recently described by Watanabe et al., was tested on 1 normal formalin-fixed human hearts suspended in a mineral oil bath. Volumes are estimated from multiple two-dimensional echocardiographic views recorded from a single point at sequential angles. The product of sectional cavity area and center of mass for each view summed over the range of angles (using a trapezoidal rule) gives volume. Multiple (8-14) short axis right ventricle and left ventricle views at 5.0 deg intervals were videotaped. The images were digitized by two independent observers (leading-edge to leading-edge technique) and analyzed using a graphics tablet and microcomputer. Actual volumes were determined by filling the chambers with water. These data were compared to the mean of the two echo measurements.

  10. Portable Hybrid Powered Water Filtration Device

    Directory of Open Access Journals (Sweden)

    Maria Lourdes V. Balansay

    2015-08-01

    Full Text Available The existing water filtration device has features that can be developed to be more useful and functional during emergency situations. The project’s development has been aided by following provisions in PEC, NEC, NEMA and Philippine National Standard for Safe Drinking Water provide standards for the construction of the project. These standards protect both the prototype and the user. These also served as guide for the maintenance of every component. The design of the portable hybrid powered water filtration device shows that the project has more advanced features such as portability and the power supply used such as photovoltaic module solar cells and manually operated generator. This also shows its effectiveness and reliability based on the results of discharging test, water quality test and water production test. Based on analysis of the overall financial aspects, the machine can be profitable and the amount of revenue and operating cost will increase as years pass. Using the proper machine/ tools and methods of fabrication helps in easy assembly of the project. The materials and components used are cost effective and efficient. The best time for charging the battery using solar panel is 9:00 am onwards while the hand crank generator is too slow because the generated current is little. The water filtration device is very efficient regarding the operating hours and water production. The machine may have a great effect to society and economy in generation of clean available water at less cost.

  11. Uptake of wheel-filtration among clients of a supervised injecting facility: Can structured education work?

    Science.gov (United States)

    Steele, Maureen; Silins, Edmund; Flaherty, Ian; Hiley, Sarah; van Breda, Nick; Jauncey, Marianne

    2018-01-01

    Wheel-filtration of pharmaceutical opioid tablets is a recognised harm reduction strategy, but uptake of the practice among people who inject drugs is low. The study aimed to: (i) examine perceptions of filtration practices; (ii) provide structured education on wheel-filtration; and (iii) assess uptake of the practice. Frequent opioid tablet injectors (n = 30) attending a supervised injecting facility in Sydney, Australia, received hands-on instruction on wheel-filtration based on recommended practice. Pre-education, post-education and follow-up questionnaires were administered. Wheel-filtration was generally regarded as better than cotton-filtration (the typical method) in terms of perceived effects on health, ease of use and overall drug effect. Sixty-eight percent of those who said they would try wheel-filtration after the education had actually done so. Of those who usually used cotton-filtration, over half (60%) had used wheel-filtration two weeks later. Uptake of safer preparation methods for pharmaceutical opioid tablets increases after structured education in wheel-filtration. Findings suggest that SIFs are an effective site for this kind of education. Supervised injecting facility workers are uniquely positioned to provide harm reduction education at the time of injection. [Steele M, Silins E, Flaherty I, Hiley S, van Breda N, Jauncey M. Uptake of wheel-filtration among clients of a supervised injecting facility: Can structured education work? Drug Alcohol Rev 2018;37:116-120]. © 2017 Australasian Professional Society on Alcohol and other Drugs.

  12. Measuring of filtration efficiency of nonwoven textiles in volume from scattered light by seeding particles

    Directory of Open Access Journals (Sweden)

    Sidlof P.

    2013-04-01

    Full Text Available This paper deals with the method which calculates a filtration efficiency of nonwoven textiles from scattered light intensity by seeding particles. Thefiltration efficiency is commonly measured by particle counters. Samples of liquid or gas are taken during a test in front of and behind a filtration material. The concentration of particles is measured and the filtration efficiency is calculated. The filtration efficiency does not have to be uniform in itswhole surface. The uniformity of filtration is another indicator of a quality of filtration materials. Measurements described in this article were performed on a water filtration setup which enables optical access to the place where the filtration material is mounted. Pictures of illuminated seeding particles are made by a laser sheet and a camera. Visualisation of the filtration process enables measuring of the efficiency of separation versus time and also versus two-dimensional position in case of use of a traverse mechanism. The filtration textiles were tested by 1 μm seeding particles. Mean value of light intensity and number of bright pixels in evaluative areas during image analysis were obtained. On the basis of these data, the filtration efficiency iscalculated. The best image analysis method was chosen.

  13. Filtration and compression of organic materials

    DEFF Research Database (Denmark)

    Christensen, Morten Lykkegaard; Keiding, Kristian

    is to use more simple systems. Dextran-MnO2 particles and polystyrene particles with a water-swollen polyacrylic acid shell have therefore been synthesised. These particles have been filtered and used to study the non-linear filtration behaviour. The compressibility of the formed cake has been investigated......The conventional filtration theory has been based on filtrations of incompressible particles such as anatase, kaolin and clay. The filtration models have later been used for organic slurries but can often not explain the observed experimental data. At constant pressure, the filtrate volume does...... and the discrepancy between the filtration theory and the observed filtration behaviour explained as a time-dependent collapse of the formed cake (creep). Thus, the creep phenomenon has been adopted in the conventional filtration models and it will be shown that the model can be used to simulate filtration data...

  14. Investigation of Microgranular Adsorptive Filtration System

    Science.gov (United States)

    Cai, Zhenxiao

    Over the past few decades, enormous advances have been made in the application of low-pressure membrane filtration to both drinking water and wastewater treatment. Nevertheless, the full potential of this technology has not been reached, due primarily to limitations imposed by membrane fouling. In drinking water treatment, much of the fouling is caused by soluble and particulate natural organic matter (NOM). Efforts to overcome the problem have focused on removal of NOM from the feed solution, usually by addition of conventional coagulants like alum and ferric chloride (FeCl3) or adsorbents like powdered activated carbon (PAC). While coagulants and adsorbents can remove a portion of the NOM, their performance with respect to fouling control has been inconsistent, often reducing fouling but sometimes having no effect or even exacerbating fouling. This research investigated microgranular adsorptive filtration (muGAF), a process that combines three existing technologies---granular media filtration, packed bed adsorption, and membrane filtration---in a novel way to reduce membrane fouling while simultaneously removing NOM from water. In this technology, a thin layer of micron-sized adsorbent particles is deposited on the membrane prior to delivering the feed to the system. The research reported here represents the first systematic study of muGAF, and the results demonstrate the promising potential of this process. A new, aluminum-oxide-based adsorbent---heated aluminum oxide particles (HAOPs)---was synthesized and shown to be very effective for NOM removal as well as fouling reduction in muGAF systems. muGAF has also been demonstrated to work well with powdered activated carbon (PAC) as the adsorbent, but not as well as when HAOPs are used; the process has also been successful when used with several different membrane types and configurations. Experiments using a wide range of operational parameters and several analytical tools lead to the conclusion that the fouling

  15. Liposomal solubilization of new 3-hydroxy-quinolinone derivatives with promising anticancer activity: a screening method to identify maximum incorporation capacity

    DEFF Research Database (Denmark)

    Di Cagno, Massimiliano; Styskala, Jakub; Hlaváč, Jan

    2011-01-01

    Four new 3-hydroxy-quinolinone derivatives with promising anticancer activity could be solubilized using liposomes as vehicle to an extent that allows their in vitro and in vivo testing without use of toxic solvent(s). A screening method to identify the maximum incorporation capacity of hydrophobic......, resulting in a 200-500-fold increase in apparent solubility. Drug-to-lipid ratios in the range of 2-5 µg/mg were obtained. Interestingly, the four quinolinone derivatives have shown different association tendencies with liposomes, probably due to the physicochemical properties of the different group bonded...

  16. Establishment and application of milk fingerprint by gel filtration chromatography.

    Science.gov (United States)

    Gao, P; Li, J; Li, Z; Hao, J; Zan, L

    2016-12-01

    Raw milk adulteration frequently occurs in undeveloped countries. It not only reduces the nutritional value of milk, but it is also harmful to consumers. In this paper, we focused on investigating an efficient method for the quality control of raw milk protein. A gel filtration chromatography (GFC) fingerprint method combined with chemometrics was developed for fingerprint analysis of raw milk. To optimize the GFC conditions, milk fat was removed by centrifugation, and GFC analysis was performed on a Superdex 75 10/300GL column (Just Scientific, Shanghai, China) with 0.2 M NaH 2 PO 4 -Na 2 HPO 4 buffer (pH 7.0) as the mobile phase. The flow rate was 0.5mL/min, and the detection wavelength was set at 280 nm. Ten batches of 120 raw milk samples were analyzed to establish the GFC fingerprint under optimal conditions. Six major peaks common to the chromatogram of each raw milk sample were selected for fingerprint analysis, and the characteristic peaks were used to establish a standard chromatographic fingerprint. Principal component analysis was then applied to classify GFC information of adulterated milk and raw milk, allowing adulterated samples to be effectively screened out from the raw milk in principal component analysis scores plot. The fingerprint method demonstrates promising features in detecting milk protein adulteration. Copyright © 2016 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.

  17. Optimization of suspensions filtration with compressible cake

    Directory of Open Access Journals (Sweden)

    Janacova Dagmar

    2016-01-01

    Full Text Available In this paper there is described filtering process for separating reaction mixture after enzymatic hydrolysis to process the chromium tanning waste. Filtration of this mixture is very complicated because it is case of mixture filtration with compressible cake. Successful process strongly depends on mathematical describing of filtration, calculating optimal values of pressure difference, specific resistant of filtration cake and temperature maintenance which is connected with viscosity change. The mathematic model of filtration with compressible cake we verified in laboratory conditions on special filtration device developed on our department.

  18. Evaluation of the filtration performance of NIOSH-approved N95 filtering facepiece respirators by photometric and number-based test methods.

    Science.gov (United States)

    Rengasamy, Samy; Miller, Adam; Eimer, Benjamin C

    2011-01-01

    N95 particulate filtering facepiece respirators are certified by measuring penetration levels photometrically with a presumed severe case test method using charge neutralized NaCl aerosols at 85 L/min. However, penetration values obtained by photometric methods have not been compared with count-based methods using contemporary respirators composed of electrostatic filter media and challenged with both generated and ambient aerosols. To better understand the effects of key test parameters (e.g., particle charge, detection method), initial penetration levels for five N95 model filtering facepiece respirators were measured using NaCl aerosols with the aerosol challenge and test equipment employed in the NIOSH respirator certification method (photometric) and compared with an ultrafine condensation particle counter method (count based) for the same NaCl aerosols as well as for ambient room air particles. Penetrations using the NIOSH test method were several-fold less than the penetrations obtained by the ultrafine condensation particle counter for NaCl aerosols as well as for room particles indicating that penetration measurement based on particle counting offers a more difficult challenge than the photometric method, which lacks sensitivity for particles photometric method may not be a more challenging aerosol test method. Filter penetrations can vary among workplaces with different particle size distributions, which suggests the need for the development of new or revised "more challenging" aerosol test methods for NIOSH certification of respirators.

  19. Filtration set for gaseous fluids

    International Nuclear Information System (INIS)

    Lebrun, B.; Couvrat-Desvergnes, A.

    1988-01-01

    This filtration set is made by a cylindrical vessel containing upstairs to downstairs, the gas inlet, a sealed floor for man inspection, a horizontal granular filter bed, a linen with a porosity inferior to the granulometry of the filter bed, a light support layer of material of larger granulometry, gas permeable tubes and an annular collector connecting the tubes to the outlet [fr

  20. Filtration device for active effluents

    International Nuclear Information System (INIS)

    Guerin, M.; Meunier, G.

    1994-01-01

    Among the various techniques relating to solid/liquid separations, filtration is currently utilized for treating radioactive effluents. After testing different equipments on various simulated effluents, the Valduc Center has decided to substitute a monoplate filter for a rotative diatomite precoated filter

  1. ROLLER FILTRATION APPARATUS

    DEFF Research Database (Denmark)

    2017-01-01

    The present invention relates to the field of filtering, more precisely the present invention concerns an apparatus and a method for the separation of dry matter from a medium and the use of said apparatus. One embodiment discloses an apparatus for the separation of dry matter and liquid from a m...

  2. Pore roller filtration apparatus

    DEFF Research Database (Denmark)

    2014-01-01

    The present invention relates to the field of filtering, more precisely the present invention concerns an apparatus and a method for the separation of dry matter from a medium and the use of said apparatus. One embodiment discloses an apparatus for the separation of dry matter from a medium, comp...

  3. In situ measurement of the efficiency of filtration installations in the nuclear industry by the soda-fluorescein (uranin) aerosol method: AFNOR standard NFX 44.011

    International Nuclear Information System (INIS)

    Dupoux, J.

    1981-01-01

    The in situ measurement of the efficiency of filtering installations in the French nuclear industry using the soda-fluorescein (uraniun) aerosol method is presented. A brief description and the interest of the method are discussed. Its use for the location of defects in filter elements and for in situ control of casing with tandem HEPA filter stages is described

  4. Nanoparticle filtration performance of NIOSH-certified particulate air-purifying filtering facepiece respirators: evaluation by light scattering photometric and particle number-based test methods.

    Science.gov (United States)

    Rengasamy, Samy; Eimer, Benjamin C

    2012-01-01

    National Institute for Occupational Safety and Health (NIOSH) certification test methods employ charge neutralized NaCl or dioctyl phthalate (DOP) aerosols to measure filter penetration levels of air-purifying particulate respirators photometrically using a TSI 8130 automated filter tester at 85 L/min. A previous study in our laboratory found that widely different filter penetration levels were measured for nanoparticles depending on whether a particle number (count)-based detector or a photometric detector was used. The purpose of this study was to better understand the influence of key test parameters, including filter media type, challenge aerosol size range, and detector system. Initial penetration levels for 17 models of NIOSH-approved N-, R-, and P-series filtering facepiece respirators were measured using the TSI 8130 photometric method and compared with the particle number-based penetration (obtained using two ultrafine condensation particle counters) for the same challenge aerosols generated by the TSI 8130. In general, the penetration obtained by the photometric method was less than the penetration obtained with the number-based method. Filter penetration was also measured for ambient room aerosols. Penetration measured by the TSI 8130 photometric method was lower than the number-based ambient aerosol penetration values. Number-based monodisperse NaCl aerosol penetration measurements showed that the most penetrating particle size was in the 50 nm range for all respirator models tested, with the exception of one model at ~200 nm size. Respirator models containing electrostatic filter media also showed lower penetration values with the TSI 8130 photometric method than the number-based penetration obtained for the most penetrating monodisperse particles. Results suggest that to provide a more challenging respirator filter test method than what is currently used for respirators containing electrostatic media, the test method should utilize a sufficient number

  5. Filtrations of free groups as intersections

    OpenAIRE

    Efrat, Ido

    2013-01-01

    For several natural filtrations of a free group S we express the n-th term of the filtration as the intersection of all kernels of homomorphisms from S to certain groups of upper-triangular unipotent matrices. This generalizes a classical result of Grun for the lower central filtration. In particular, we do this for the n-th term in the lower p-central filtration of S.

  6. Hot filtration 1

    International Nuclear Information System (INIS)

    Barbieri, R.R.; Krikscikas de Blanco, Elsa; Liberman, S.J.

    1982-01-01

    The study of graphite filters is a subject of interest since they provide a convenient method for water cleaning at high temperature in nuclear power stations. The contribution of the double layer interaction on the mechanism of magnetite deposition on granular graphite beds was determined by measuring retention efficiencies, differential pressures across the bed and electrophoretic mobilities as a function of pH. At pH 5 a flat maximum in the retention efficiency and a deep minimum in the superficial energy of interaction as a function of pH were obtained. These results show that, even though the double layer interaction is responsible for the changes of the retention efficiency with pH, its contribution does not play an important role on the mechanism of the deposition of the magnetite particles in the graphite bed. It is suggested that the pores' mechanical obstruction effect by particle's aggregation could be a factor of great influence on the retention efficiency. (Author) [es

  7. Portable field water sample filtration unit

    International Nuclear Information System (INIS)

    Hebert, A.J.; Young, G.G.

    1977-01-01

    A lightweight back-packable field-tested filtration unit is described. The unit is easily cleaned without cross contamination at the part-per-billion level and allows rapid filtration of boiling hot and sometimes muddy water. The filtration results in samples that are free of bacteria and particulates and which resist algae growth even after storage for months. 3 figures

  8. Method of Determining the Filtration Properties of oil-Bearing Crops in the Process of Their Pressing by the Example of Rape-oil Extrusion

    Science.gov (United States)

    Slavnov, E. V.; Petrov, I. A.

    2014-07-01

    A method of determining the change in the fi ltration properties of oil-bearing crops in the process of their pressing by repeated dynamic loading is proposed. The use of this method is demonstrated by the example of rape-oil extrusion. It was established that the change in the mass concentration of the oil in a rape mix from 0.45 to 0.23 leads to a decrease in the permeability of the mix by 101.5-102 times depending on the pressure applied to it. It is shown that the dependence of the permeability of this mix on the pressure applied to it is nonmonotone in character.

  9. Removal of heavy metals and radionuclides by seeded magnetic filtration

    International Nuclear Information System (INIS)

    Bibler, J.P.; Norrell, G.; Hemmings, R.L.; Bradbury, D.; Dunn, M.J.; Kalinauskas, G.L.

    1991-01-01

    Removal of traces of heavy metal or radionuclide contamination from solution at high flow rate presents a considerable technical challenge. Low flow methods of treatment such as particle gravity settling require expensive large volume equipment, whereas traditional methods of filtration can cause significant energy costs. Magnetic filtration can be used to provide a low cost method of solid-liquid separation at high flow rate, provided contaminants can be selectively bound to a magnetic solid particle. This paper describes the use of such selective magnetic particles made up of inorganic particles coupled with organic polymers

  10. Demonstration of creep during filtration

    DEFF Research Database (Denmark)

    Christensen, Morten Lykkegaard; Bugge, Thomas Vistisen; Kirchheiner, Anders Løvenbalk

    The classical filtration theory assumes a unique relationship between the local filter cake porosity and the local effective pressure. For a number of compressible materials, it has however been observed that during the consolidation stage this may not be the case. It has been found...... that the production of filtrate also depends on the characteristic time for the filter cake solids to deform. This is formulated in the Terzaghi-Voigt model in which a secondary consolidation is introduced. The secondary consolidation may be visualized by plots of the relative cake deformation (U) v.s. the square...... root of time. Even more clearly it is demonstrated by plotting the liquid pressure at the cake piston interface v.s. the relative deformation (to be shown). The phenomenon of a secondary consolidation processes is in short called creep. Provided that the secondary consolidation rate is of the same...

  11. Properties of plastic filtration material

    Energy Technology Data Exchange (ETDEWEB)

    Paluch, W.

    1988-01-01

    Discusses properties of filters made of thermoplastic granulated material. The granulated plastic has a specific density of 10.3-10.6 kN/m/sup 3/ and a bulk density of about 6 kN/m/sup 3/. Its chemical resistance to acids, bases and salts is high but is it soluble in organic solvents. Filters made of this material are characterized by a porosity coefficient of 36.5% and a bulk density of 5.7-6.8 kN/m/sup 3/. Physical and mechanical properties of filter samples made of thermoplastic granulated material (50x50x50 mm) were investigated under laboratory conditions. Compression strength and influencing factors were analyzed (ambient temperature, manufacturing technology). Tests show that this filtration material developed by Poltegor is superior to other filtration materials used in Poland.

  12. Fast Filtration of Bacterial or Mammalian Suspension Cell Cultures for Optimal Metabolomics Results.

    Directory of Open Access Journals (Sweden)

    Natalie Bordag

    Full Text Available The metabolome offers real time detection of the adaptive, multi-parametric response of the organisms to environmental changes, pathophysiological stimuli or genetic modifications and thus rationalizes the optimization of cell cultures in bioprocessing. In bioprocessing the measurement of physiological intracellular metabolite levels is imperative for successful applications. However, a sampling method applicable to all cell types with little to no validation effort which simultaneously offers high recovery rates, high metabolite coverage and sufficient removal of extracellular contaminations is still missing. Here, quenching, centrifugation and fast filtration were compared and fast filtration in combination with a stabilizing washing solution was identified as the most promising sampling method. Different influencing factors such as filter type, vacuum pressure, washing solutions were comprehensively tested. The improved fast filtration method (MxP® FastQuench followed by routine lipid/polar extraction delivers a broad metabolite coverage and recovery reflecting well physiological intracellular metabolite levels for different cell types, such as bacteria (Escherichia coli as well as mammalian cells chinese hamster ovary (CHO and mouse myeloma cells (NS0.The proposed MxP® FastQuench allows sampling, i.e. separation of cells from medium with washing and quenching, in less than 30 seconds and is robustly designed to be applicable to all cell types. The washing solution contains the carbon source respectively the 13C-labeled carbon source to avoid nutritional stress during sampling. This method is also compatible with automation which would further reduce sampling times and the variability of metabolite profiling data.

  13. EFSA BIOHAZ Panel (EFSA Panel on Biological Hazards), 2015. Scientific Opinion on an alternative method for the hygienic treatment of bovine colostrum through a series of filtration steps

    DEFF Research Database (Denmark)

    Hald, Tine

    An alternative method to the HTST treatment (High Temperature Short Time pasteurisation at 72 °C for at least 15 seconds or equivalent pasteurisation effect achieving a negative reaction to a phosphatase test), approved for the treatment of bovine colostrum (Category 3 material), was assessed...... process reduces the relevant viral contaminants to a level at least equivalent to a single HTST treatment as required by the legislation....

  14. Renal filtration function in patients with gout

    Directory of Open Access Journals (Sweden)

    N. N. Kushnarenko

    2016-01-01

    Full Text Available Aim. To study circadian blood pressure (BP profile in patients with gout depending on the presence of arterial hypertension (HT and their relationship to the renal filtration function.Material and methods. Patients with gout (n=87 were included into the study. All the patients underwent ambulatory BP monitoring (ABPM with the assessment of circadian BP profile, determination of uric acid serum levels, glomerular filtration rate (GFR was evaluated by CKD-EPI method. Depending on GFR level, all the patients were divided into 2 groups - with renal dysfunction or without one.Results. ABPM revealed circadian BP dysregulation in 55% of gout patients both with HT and without HT. Chronic kidney disease (CKD was revealed in 72.4% of male patients, with the prevalence in patients with HT (76.6 vs 61%; p<0.001. Correlations between uric acid levels and some ABPM indicators and GFR were determined.Conclusion. Obtained data suggest the contribution of hyperuricemia in disorders of systemic and renal hemodynamics, leading to the early development of CKD.

  15. Elicited vs. voluntary promises

    NARCIS (Netherlands)

    Ismayilov, H.; Potters, Jan

    2017-01-01

    We set up an experiment with pre-play communication to study the impact of promise elicitation by trustors from trustees on trust and trustworthiness. When given the opportunity a majority of trustors solicits a promise from the trustee. This drives up the promise making rate by trustees to almost

  16. Riverbed Clogging and Sustainability of Riverbank Filtration

    Directory of Open Access Journals (Sweden)

    Thomas Grischek

    2016-12-01

    Full Text Available Clogging refers to a reduction of riverbed hydraulic conductivity. Due to difficulties in determining the thickness of the clogging layer, the leakage coefficient (L is introduced and used to quantify the recoverable portion of bank filtrate. L was determined at several riverbank filtration (RBF sites in field tests and using an analytical solution. Results were compared with data from similar experiments in the early 1970s and 1991–1993. In the 1980s, severe river water pollution in conjunction with high water abstraction led to partly unsaturated conditions beneath the riverbed. A leakage coefficient L of 5 × 10−7 s−1 was determined. After water quality improvement, L increased to 1–1.5 × 10−6 s−1. An alternative, cost and time efficient method is presented to estimate accurate leakage coefficients. The analytical solution is based on groundwater level monitoring data from observation wells next to the river, which can later feed into numerical models. The analytical approach was able to reflect long-term changes as well as seasonal variations. Recommendations for its application are given based on experience.

  17. Water filtration using plant xylem.

    Directory of Open Access Journals (Sweden)

    Michael S H Boutilier

    Full Text Available Effective point-of-use devices for providing safe drinking water are urgently needed to reduce the global burden of waterborne disease. Here we show that plant xylem from the sapwood of coniferous trees--a readily available, inexpensive, biodegradable, and disposable material--can remove bacteria from water by simple pressure-driven filtration. Approximately 3 cm(3 of sapwood can filter water at the rate of several liters per day, sufficient to meet the clean drinking water needs of one person. The results demonstrate the potential of plant xylem to address the need for pathogen-free drinking water in developing countries and resource-limited settings.

  18. CALCULATION OF LONG-TERM FILTRATION IN A POROUS MEDIUM

    Directory of Open Access Journals (Sweden)

    Ludmila I. Kuzmina

    2018-03-01

    Full Text Available he filtration problem in a porous medium is an important part of underground hydromechanics. Filtration of suspensions and colloids determines the processes of strengthening the soil and creating waterproof walls in the ground while building the foundations of buildings and underground structures. It is assumed that the formation of a deposit is dominated by the size-exclusion mechanism of pore blocking: solid particles pass freely through large pores and get stuck at the inlet of pores smaller than the diameter of the particles. A one-dimensional mathematical model for the filtration of a monodisperse suspension includes the equation for the mass balance of suspended and retained particles and the kinetic equation for the growth of the deposit. For the blocking filtration coefficient with a double root, the exact solution is given implicitly. The asymptotics of the filtration problem is constructed for large time. The numerical calculation of the problem is carried out by the finite differences method. It is shown that asymptotic approximations rapidly converge to a solution with the increase of the expansion order.

  19. The Fundamentals of Waste Water Sludge Characterization and Filtration

    Energy Technology Data Exchange (ETDEWEB)

    Scales, Peter J.; Dixon, David R.; Harbour, Peter J.; Stickland, Anthony D.

    2003-07-01

    The move to greater emphasis on the disposal of waste water sludges through routes such as incineration and the added cost of landfill emplacement puts high demands on dewatering technology for these sludges. A dear problem in this area is that waste water sludges are slow and difficult to dewater and traditional methods of laboratory measurement for prediction of filtration performance are inadequate. This is highly problematic for the design and operational optimisation of centrifuges, filters and settling devices in the waste water industry. The behaviour is assessed as being due to non-linear behaviour of these sludges which negates the use of classical approaches. These approaches utilise the linear portion of a t versus V{sup 2} plot (where t is the time to filtration and V is the specific filtrate volume) to extract a simple Darcian permeability. Without this parameter, a predictive capacity for dewatering using current theory is negated. (author)

  20. In-Water Hull Cleaning & Filtration System

    Science.gov (United States)

    George, Dan

    2015-04-01

    Dan George R & D Mining Technology LinkedIn GRD Franmarine have received the following prestigious awards in 2014 for their research & development of an in-water hull cleaning and filtration system "The Envirocart: Golden Gecko Award for Environmental Excellence; WA Innovator of the Year - Growth Sector; Department of Fisheries - Excellence in Marine Biosecurity Award - Innovation Category; Lloyd's List Asia Awards - Environmental Award; The Australian Innovation Challenge - Environment, Agriculture and Food Category; and Australian Shipping and Maritime Industry Award - Environmental Transport Award. The Envirocart developed and patented by GRD Franmarine is a revolutionary new fully enclosed capture and containment in-water hull cleaning technology. The Envirocart enables soft Silicon based antifouling paints and coatings containing pesticides such as Copper Oxide to be cleaned in situ using a contactless cleaning method. This fully containerised system is now capable of being deployed to remote locations or directly onto a Dive Support Vessel and is rated to offshore specifications. This is the only known method of in-water hull cleaning that complies with the Department of Agriculture Fisheries and Forestry (DAFF) and Department of Fisheries WA (DoF) Guidelines. The primary underwater cleaning tool is a hydraulically powered hull cleaning unit fitted with rotating discs. The discs can be fitted with conventional brushes for glass or epoxy based coatings or a revolutionary new patented blade system which can remove marine biofouling without damaging the antifouling paint (silicone and copper oxide). Additionally there are a patented range of fully enclosed hand cleaning tools for difficult to access niche areas such as anodes and sea chests, providing an innovative total solution that enables in-water cleaning to be conducted in a manner that causes no biological risk to the environment. In full containment mode or when AIS are present, material is pumped

  1. Simulation of impaction filtration of aerosol droplets in porous media

    OpenAIRE

    Ghazaryan, L.; Lopez Penha, D.J.; Geurts, Bernardus J.; Stolz, S.; Stolz, Steffen; Winkelmann, Christoph; Pereira, J.C.F; Sequeira, A.; Pereira, J.M.C.

    2010-01-01

    We report on the development of a method to simulate from first principles the particle filtration efficiency of filters that are composed of structured porous media. We assume that the ratio of particle density to the fluid density is high. We concentrate on the motion of the particles in a laminar flow and quantify the role of inertial effects on the filtration of an ensemble of particles. We adopt the Euler-Lagrange approach, distinguishing a flow field in which the motion of a large numbe...

  2. Cost calculator methods for estimating casework time in child welfare services: A promising approach for use in implementation of evidence-based practices and other service innovations.

    Science.gov (United States)

    Holmes, Lisa; Landsverk, John; Ward, Harriet; Rolls-Reutz, Jennifer; Saldana, Lisa; Wulczyn, Fred; Chamberlain, Patricia

    2014-04-01

    Estimating costs in child welfare services is critical as new service models are incorporated into routine practice. This paper describes a unit costing estimation system developed in England (cost calculator) together with a pilot test of its utility in the United States where unit costs are routinely available for health services but not for child welfare services. The cost calculator approach uses a unified conceptual model that focuses on eight core child welfare processes. Comparison of these core processes in England and in four counties in the United States suggests that the underlying child welfare processes generated from England were perceived as very similar by child welfare staff in California county systems with some exceptions in the review and legal processes. Overall, the adaptation of the cost calculator for use in the United States child welfare systems appears promising. The paper also compares the cost calculator approach to the workload approach widely used in the United States and concludes that there are distinct differences between the two approaches with some possible advantages to the use of the cost calculator approach, especially in the use of this method for estimating child welfare costs in relation to the incorporation of evidence-based interventions into routine practice.

  3. Side Stream Filtration for Cooling Towers

    Energy Technology Data Exchange (ETDEWEB)

    None

    2012-10-20

    This technology evaluation assesses side stream filtration options for cooling towers, with an objective to assess key attributes that optimize energy and water savings along with providing information on specific technology and implementation options. This information can be used to assist Federal sites to determine which options may be most appropriate for their applications. This evaluation provides an overview of the characterization of side stream filtration technology, describes typical applications, and details specific types of filtration technology.

  4. Relation Between Filtration and Soil Consolidation Theories

    OpenAIRE

    Strzelecki Tomasz; Strzelecki Michał

    2015-01-01

    This paper presents a different, than commonly used, form of equations describing the filtration of a viscous compressible fluid through a porous medium in isothermal conditions. This mathematical model is compared with the liquid flow equations used in the theory of consolidation. It is shown that the current commonly used filtration model representation significantly differs from the filtration process representation in Biot’s and Terzaghi’s soil consolidation models, which has a bearing on...

  5. Filtration of Sludge and Sodium Nonatitanate Solutions

    International Nuclear Information System (INIS)

    Poirier, M.R.

    2000-01-01

    The proposed facility designs for the ion exchange and solvent extraction flowsheets under development to treat high level waste at the Savannah River Site use crossflow filtration to remove entrained sludge and monosodium titanate (MST). Bench-scale and pilot-scale testing performed with simulated feed streams showed much lower filtration rates than desired for the process. This report documents an investigation of the impact on filtration of using Honeywell sodium nonatitanate (ST), rather than MST, for strontium and actinide removal

  6. Simulation of impaction filtration of aerosol droplets in porous media

    NARCIS (Netherlands)

    Ghazaryan, L.; Lopez Penha, D.J.; Geurts, Bernardus J.; Stolz, S.; Stolz, Steffen; Winkelmann, Christoph; Pereira, J.C.F; Sequeira, A.; Pereira, J.M.C.

    2010-01-01

    We report on the development of a method to simulate from first principles the particle filtration efficiency of filters that are composed of structured porous media. We assume that the ratio of particle density to the fluid density is high. We concentrate on the motion of the particles in a laminar

  7. Cake creep during filtration of flocculated manure

    DEFF Research Database (Denmark)

    Christensen, Morten Lykkegaard; Keiding, Kristian

    is filtered. Hence, it is not possible to scale up the experiments, and it is therefore difficult to optimize the flocculation and estimate the needed filter media area. Similar problems have been observed when sewage sludge and synthetic core-shell colloids are filtered, and it has been suggested......, and the mixing procedure affect the result, and lab-scale experiments are often used to study how these pre-treatments influence the filtration process. However, the existing mathematical filtration models are based on filtration of inorganic particles and cannot simulate the filtration data obtained when manure...

  8. Filtration Behaviour and Fouling Mechanisms of Polysaccharides

    Directory of Open Access Journals (Sweden)

    Sondus Jamal

    2014-07-01

    Full Text Available This study investigated filtration behaviors of polysaccharides solutions, both alone and in mixture with proteins, in the short-time constant flux filtration with the focus on factors affecting the transmembrane pressure (TMP increase rate, the irreversible filtration resistance, and the membrane rejection behavior. The results showed that the TMP increase rates in the short-time constant flux filtration of alginate solutions were significantly affected by the calcium addition, alginate concentration, and flux. Although the addition of calcium resulted in a decrease in the TMP increase rate, it was found that the irreversible fouling developed during the filtration increased with the calcium addition, implying that the double-sided effect of calcium on membrane filtration and that the TMP increase rate observed in the filtration does not always reflect the irreversible membrane fouling development. It was also found that for the filtration of solutions containing mixed alginate and BSA, alginate exerted a dominant effect on the TMP increase rate and the membrane exhibited a reduced rejection to both alginate and BSA molecules compared to that in the filtration of the pure alginate or BSA.

  9. Gravity-driven membrane system for secondary wastewater effluent treatment: Filtration performance and fouling characterization

    KAUST Repository

    Wang, Yiran; Fortunato, Luca; Jeong, Sanghyun; Leiknes, TorOve

    2017-01-01

    Gravity-driven membrane (GDM) filtration is one of the promising membrane bioreactor (MBR) configurations. It operates at an ultra-low pressure by gravity, requiring a minimal energy. The objective of this study was to understand the performance of GDM filtration system and characterize the biofouling formation on a flat sheet membrane. This submerged GDM reactor was operated at constant gravitational pressure in treating of two different concentrations of secondary wastewater effluent. Morphology of biofilm layer was acquired by an in-situ and on-line optical coherence tomography (OCT) scanning in a fixed position at regular intervals. The thickness and roughness calculated from OCT images were related to the variation of flux, fouling resistance and permeate quality. At the end of experiment, fouling was quantified by total organic carbon (TOC) and adenosine tri-phosphate (ATP) method. Confocal laser scanning microscopy (CLSM) was also applied for biofouling morphology observation. The biofouling formed on membrane surface was mostly removed by physical cleaning confirmed by contact angle measurement before and after cleaning. This demonstrated that fouling on the membrane under ultra-low pressure operation was highly reversible. The superiority and sustainability of GDM in both flux maintaining and long-term operation with production of high quality effluent was demonstrated.

  10. Gravity-driven membrane system for secondary wastewater effluent treatment: Filtration performance and fouling characterization

    KAUST Repository

    Wang, Yiran

    2017-04-21

    Gravity-driven membrane (GDM) filtration is one of the promising membrane bioreactor (MBR) configurations. It operates at an ultra-low pressure by gravity, requiring a minimal energy. The objective of this study was to understand the performance of GDM filtration system and characterize the biofouling formation on a flat sheet membrane. This submerged GDM reactor was operated at constant gravitational pressure in treating of two different concentrations of secondary wastewater effluent. Morphology of biofilm layer was acquired by an in-situ and on-line optical coherence tomography (OCT) scanning in a fixed position at regular intervals. The thickness and roughness calculated from OCT images were related to the variation of flux, fouling resistance and permeate quality. At the end of experiment, fouling was quantified by total organic carbon (TOC) and adenosine tri-phosphate (ATP) method. Confocal laser scanning microscopy (CLSM) was also applied for biofouling morphology observation. The biofouling formed on membrane surface was mostly removed by physical cleaning confirmed by contact angle measurement before and after cleaning. This demonstrated that fouling on the membrane under ultra-low pressure operation was highly reversible. The superiority and sustainability of GDM in both flux maintaining and long-term operation with production of high quality effluent was demonstrated.

  11. Filtration of sodium-fire aerosols

    International Nuclear Information System (INIS)

    Alexas, A.; Jordan, S.; Lindner, W.

    1979-01-01

    Different filter devices have been developed and tested with respect to their use in the off-gas system of liquid-metal fast breeder reactors to prevent the escape of sodium-fire aerosols that might be formed in case of an accident. The testing results have shown that the use of a multilayer sand bed filter is still the best method to filter limited amounts of sodium-fire aerosols over a long operating time. Efficiencies on the order of 99.98 and 98.8% were reached for loading capacities of 500 and 1000 g/m 2 , respectively. Unlimited amounts of sodium-fire aerosols can be filtered by wet scrubbers with an efficiency of 70% per scrubber stage. Fiberglas filters connot be used for the filtration of sodium-fire aerosols over a long operating time because the filter material can be destroyed after several days of operating

  12. A Dual Filtration-Based Multiplex PCR Method for Simultaneous Detection of Viable Escherichia coli O157:H7, Listeria monocytogenes, and Staphylococcus aureus on Fresh-Cut Cantaloupe.

    Directory of Open Access Journals (Sweden)

    Ke Feng

    Full Text Available Fresh-cut cantaloupe is particularly susceptible to contamination with pathogenic bacteria, such as Escherichia coli O157:H7, Listeria monocytogenes, and Staphylococcus aureus. Therefore, development of rapid, yet accurate detection techniques is necessary to ensure food safety. In this study, a multiplex PCR system and propidium monoazide (PMA concentration were optimized to detect all viable pathogens in a single tube. A dual filtration system utilized a filtration membrane with different pore sizes to enrich pathogens found on fresh-cut cantaloupe. The results revealed that an optimized multiplex PCR system has the ability to effectively detect three pathogens in the same tube. The viable pathogens were simultaneously detected for PMA concentrations above 10 μg/ml. The combination of a nylon membrane (15 μm and a micro pore filtration membrane (0.22 μm formed the dual filtration system used to enrich pathogens. The achieved sensitivity of PMA-mPCR based on this dual filtration system was 2.6 × 103 cfu/g for L. monocytogenes, 4.3 × 10 cfu/g for E. coli O157:H7, and 3.1 × 102 cfu/g for S. aureus. Fresh-cut cantaloupe was inoculated with the three target pathogens using concentrations of 103, 102, 10, and 1 cfu/g. After 6-h of enrichment culture, assay sensitivity increased to 1 cfu/g for each of these pathogens. Thus, this technique represents an efficient and rapid detection tool for implementation on fresh-cut cantaloupe.

  13. Keeping the Promise

    Science.gov (United States)

    Whissemore, Tabitha

    2016-01-01

    Since its launch in September 2015, Heads Up America has collected information on nearly 125 promise programs across the country, many of which were instituted long before President Barack Obama announced the America's College Promise (ACP) plan in 2015. At least 27 new free community college programs have launched in states, communities, and at…

  14. Filtration and retention capacities of filter aids

    International Nuclear Information System (INIS)

    Mellah, A.; Boualia, A.

    1992-01-01

    The present work involves the filtration of impure uranyl nitrate solutions by different filter aids such as kieselguhr, celite and bleaching clay. The retention of substances contained in uranyl nitrate solution was determined using the three filter aids. A study of the effects of granulometry and filter earths treatment (thermal and chemical) on the filtration rate was performed

  15. 40 CFR 141.73 - Filtration.

    Science.gov (United States)

    2010-07-01

    ... Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) WATER PROGRAMS (CONTINUED) NATIONAL PRIMARY DRINKING WATER REGULATIONS Filtration and Disinfection § 141.73 Filtration. A public water system that uses a surface water source or a ground water source under the direct influence of surface water...

  16. Particle filtration in consolidated granular systems

    International Nuclear Information System (INIS)

    Schwartz, L.M.; Wilkinson, D.J.; Bolsterli, M.; Hammond, P.

    1993-01-01

    Grain-packing algorithms are used to model the mechanical trapping of dilute suspensions of particles by consolidated granular media. We study the distribution of filtrate particles, the formation of a damage zone (internal filter cake), and the transport properties of the host--filter-cake composite. At the early stages of filtration, our simulations suggest simple relationships between the structure of the internal filter cake and the characteristics of the underlying host matrix. These relationships are then used to describe the dynamics of the filtration process. Depending on the grain size and porosity of the host matrix, calculated filtration rates may either be greater than (spurt loss) or less than (due to internal clogging) those predicted by standard surface-filtration models

  17. Fluoride removal from water by nano filtration

    International Nuclear Information System (INIS)

    Bejaoui, Imen; Mnif, Amine; Hamrouni, Bechir

    2009-01-01

    As any oligo element, fluoride is necessary and beneficial for human health to low concentrations, but an excess amount of fluoride ions in drinking water has been known to cause undesirable effects, especially tooth and bones fluoro sis. The maximum acceptable concentration of fluoride in drinking water was fixed by the World Health Organization according to the climate in the range of 1 mg.L -1 to 1,2 mg.L -1 . Many methods have been used to remove fluoride from water such as precipitation, adsorption, electrocoagulation and membrane processes. Technologies using membrane processes are being used in many applications, particularly for brackish water desalination. Nano filtration seems to be the best process for a good selective defluorination of fluorinated waters. The main objective of this work was to investigate the retention of fluoride anions by nano filtration. The first part of this study deals with the characterisation of the NF HL2514TF membrane. The influence of various experimental parameters such as initial fluoride content, feed pressure, permeate flux, ionic strength, type of cation associated to fluoride and pH were studied in the second part. Results show that the retention order for the salts tested was TR(Na 2 SO 4 ) > TR(CaCl 2 ) > TR(NaCl), showing a retention sequence inversely proportional to the salt diffusion coefficients in water. It was also shown that charge effects could not be neglected, and a titration experiments confirmed that the NF membrane carry a surplus of negatively charged groups. Fluoride retention exceeds 60 pour cent, and increases with increasing concentration, where the rejection mechanism is related to the dielectric effects. Speigler-Kedem model was applied to experimental results in the aim to determine phenomenological parametersσand P s respectively, the reflexion coefficient of the membrane and the solute permeability of ions. The convective and diffusive parts of the mass transfer were quantified with

  18. In Vitro Selection of Peanut Somatic Embryos on Medium Containing Culture Filtrate of Sclerotium rolfsii and Plantlet Regeneration

    Directory of Open Access Journals (Sweden)

    YUSNITA

    2005-06-01

    Full Text Available Attempts to identify somaclonal variants of peanut with resistance to Sclerotium stem rot disease due to infection of S. rolfsii were conducted. The objectives of this study were to develop in vitro selection method using culture filtrates of S. rolfsii, identify culture filtrate-insensitive somatic embryo (SE of peanut after in vitro selection and regenerate peanut R0 lines originated from culture filtrate-insensitive SE. To achieve these objectives, peanut embryogenic tissues were cultured on selective medium containing various concentrations of S. rolfsii culture filtrates and sublethal concentration of the filtrates. Medium containing sublethal level of S. rolfsii culture filtrates was used to identify culture filtrate-insensitive SE of peanut. Subsequently, the selected SEs were germinated, plantlets were regenerated and preliminary tested against S. rolfsii. Results of the experiments showed that addition of S. rolfsii culture filtrates into medium for inducing peanut somatic embryos drastically reduced their growth and proliferation. S. rolfsii culture filtrates at 10% concentration has significantly reduced the number of proliferated SE per explant. However, sublethal level was achieved at 30% of culture filtrates concentration. Responses of five peanut cultivars against 30% of culture filtrates were similar, indicating they were similar in their susceptibility against S. rolfsii. A number of culture filtrate-insensitive SE were identified after culturing 1500 clumps of embryogenic tissue of peanut cv. Kelinci for three consecutive passages on medium containing 30% of culture filtrates. Germination of selected SE and regeneration of plantlet from culture filtrate-insensitive SE resulted in 50 peanut R0 lines. These lines have been grown in the plastic house and produced normal seeds for further evaluation. Results of S. rolfsii inoculation indicated the existence of chimera for insensitivity against S. rolfsii.

  19. Osculum dynamics and filtration activity in small single-osculum explants of the demosponge Halichondria panicea

    DEFF Research Database (Denmark)

    Kumala, Lars; Riisgård, Hans Ulrik; Canfield, Donald Eugene

    2017-01-01

    the clearance method. Osculum dynamics, as expressed by temporal variation of the OSA, including osculum contraction and expansion, correlated with variability in the explant filtration rate, and no water pumping was observed during periods of osculum closure. A linear relationship between filtration rate (FR......Contraction-inflation behavior, including the closure and opening of the exhalant opening (osculum), is common among sponges. This behavior may temporally affect filtration activity, making it difficult to study and understand sponge feeding biology. To examine the interplay between osculum...... dynamics and filtration activity, small (18 mm3) single-osculum explants of the demosponge Halichondria panicea were studied. Time-lapse video stereo-microscope recordings of the osculum cross-sectional area (OSA) were made simultaneously with measurements of the filtration rate (∼15°C, ∼20 PSU) using...

  20. Promise Zones for Applicants

    Data.gov (United States)

    Department of Housing and Urban Development — This tool assists applicants to HUD's Promise Zone initiative prepare data to submit with their application by allowing applicants to draw the exact location of the...

  1. Successful Treatment Of Homozygous Familial Hypercholesterolemia Using Cascade Filtration Plasmapheresis

    Directory of Open Access Journals (Sweden)

    Fatih Kardas

    2012-12-01

    Full Text Available OBJECTIVE: The aim of our study is to discuss the efficacy of low-density lipoprotein-cholesterol (LDL-C apheresis procedure using the cascade filtration system for pediatric patients with homozygous familial hypercholesterolemia (FH, and to clarify the adverse effects and difficulties. METHODS: LDL apheresis using the cascade filtration system was performed in 3 pediatric patients with homozygous FH. In total, 120 apheresis sessions were performed for all patients. RESULTS: Cascade filtration therapy significantly reduced the mean LDL-C values from 418 ± 62 mg/dl to 145 ± 43 mg/dl (p<0.05. We determined an acute mean reduction in the plasma levels of total cholesterol (57.9%, LDL cholesterol (70.8%, and high-density lipoprotein (HDL cholesterol (40.7%. Treatments were well tolerated. The most frequent clinical adverse effects were hypotension in 3 sessions (2.5%, chills/feeling cold (1.7% in 2 sessions, and nausea and vomiting in 3 sessions (2.5%. CONCLUSION: Our experience with three patients using the cascade filtration system were, good clinical outcomes, laboratory findings, safety of usage, minor adverse effects and technical problems.

  2. Complexant Identification in Hanford Waste Simulant Sr/TRU Filtrate

    International Nuclear Information System (INIS)

    Bannochie, C.J.

    2003-01-01

    This project was designed to characterize the available multidentate ligand species and metal ion complexes of iron, strontium and manganese formed with the parent chelators, complexing agents and their fragment products. Complex identification was applied to AN-102 and AN-107 filtrate simulants for Hanford waste after an oxidation reaction with sodium permanganate to create a freshly precipitated manganese dioxide solid for adsorption of transuranic elements. Separation efficiency of different ligands was investigated based on the exchange capability of different ion exchange and ion exclusion analytical columns including Dionex IonPac AS-5A, AS-10, AS-11 and AS-6. The elution programs developed with different mobile phase concentrations were based on the change in the effective charge of the anionic species and therefore the retention on the stationary phase. In the present work, qualitative and quantitative assessments of multidentate ligands were investigated. Identification methods for the metal ion complexes responsible for solubilizing Fe, Mn and Sr were applied to aged and fresh simulant waste filtrates. Although concentration measurements of both fresh and 3-week aged filtrates showed that the degradation process occurs mainly due to the harsh chemical environment, it was found that the concentration of iron and manganese did not increase, within the error of the analytical measurements, after three weeks when compared with fresh filtrate

  3. Dynamic Heterogeneous Multiscale Filtration Model: Probing Micro- and Macroscopic Filtration Characteristics of Gasoline Particulate Filters.

    Science.gov (United States)

    Gong, Jian; Viswanathan, Sandeep; Rothamer, David A; Foster, David E; Rutland, Christopher J

    2017-10-03

    Motivated by high filtration efficiency (mass- and number-based) and low pressure drop requirements for gasoline particulate filters (GPFs), a previously developed heterogeneous multiscale filtration (HMF) model is extended to simulate dynamic filtration characteristics of GPFs. This dynamic HMF model is based on a probability density function (PDF) description of the pore size distribution and classical filtration theory. The microstructure of the porous substrate in a GPF is resolved and included in the model. Fundamental particulate filtration experiments were conducted using an exhaust filtration analysis (EFA) system for model validation. The particulate in the filtration experiments was sampled from a spark-ignition direct-injection (SIDI) gasoline engine. With the dynamic HMF model, evolution of the microscopic characteristics of the substrate (pore size distribution, porosity, permeability, and deposited particulate inside the porous substrate) during filtration can be probed. Also, predicted macroscopic filtration characteristics including particle number concentration and normalized pressure drop show good agreement with the experimental data. The resulting dynamic HMF model can be used to study the dynamic particulate filtration process in GPFs with distinct microstructures, serving as a powerful tool for GPF design and optimization.

  4. User evaluations offer promise for pod-intravaginal ring as a drug delivery platform: A mixed methods study of acceptability and use experiences.

    Science.gov (United States)

    Guthrie, Kate M; Rosen, Rochelle K; Vargas, Sara E; Getz, Melissa L; Dawson, Lauren; Guillen, Melissa; Ramirez, Jaime J; Baum, Marc M; Vincent, Kathleen L

    2018-01-01

    Effective HIV prevention requires efficient delivery of safe and efficacious drugs and optimization of user adherence. The user's experiences with the drug, delivery system, and use parameters are critical to product acceptability and adherence. Prevention product developers have the opportunity to directly control a drug delivery system and its impact on acceptability and adherence, as well as product efficacy. Involvement of potential users during preclinical design and development can facilitate this process. We embedded a mixed methods user evaluation study into a safety and pharmacokinetics (PK) trial of a pod-intravaginal ring delivering antiretroviral agents. Women enrolled in two cohorts, ultimately evaluating the safety/PK of a pod-IVRs delivering TDF-alone, TDF-FTC, and/or TDF-FTC-MVC. A 7-day use period was targeted for each pod-IVR, regardless of drug or drug combination. During the clinical study, participants provided both quantitative (i.e., survey) and qualitative (i.e., in-depth interview) data capturing acceptability, perceptibility, and adherence behaviors. Initial sexual and reproductive health history surveys, daily diaries, a final acceptability and willingness to use survey, and a qualitative in-depth interview comprised the user evaluation data for each pod-IVR experienced by the participants. Overall, the majority of participants (N = 10) reported being willing to use the pod-IVR platform for HIV prevention should it advance to market. Confidence to use the pod-IVR (e.g., insertion, removal) was high. There were no differences noted in the user experience of the pod-IVR platform; that is, whether the ring delivered TDF-alone, TDF-FTC, or TDF-FTC-MVC, users' experiences of the ring were similar and acceptable. Participants did report specific experiences, both sensory and behavioral, that impacted their use behaviors with respect to the ring, and which could ultimately impact acceptability and adherence. These experiences, and user

  5. Quantitative measurement and visualization of biofilm O 2 consumption rates in membrane filtration systems

    KAUST Repository

    Prest, Emmanuelle I E C; Staal, Marc J.; Kü hl, Michael; van Loosdrecht, Mark C.M.; Vrouwenvelder, Johannes S.

    2012-01-01

    There is a strong need for techniques enabling direct assessment of biological activity of biofouling in membrane filtration systems. Here we present a new quantitative and non-destructive method for mapping O 2 dynamics in biofilms during

  6. Promising More Information

    Science.gov (United States)

    2003-01-01

    When NASA needed a real-time, online database system capable of tracking documentation changes in its propulsion test facilities, engineers at Stennis Space Center joined with ECT International, of Brookfield, Wisconsin, to create a solution. Through NASA's Dual-Use Program, ECT developed Exdata, a software program that works within the company's existing Promise software. Exdata not only satisfied NASA s requirements, but also expanded ECT s commercial product line. Promise, ECT s primary product, is an intelligent software program with specialized functions for designing and documenting electrical control systems. An addon to AutoCAD software, Promis e generates control system schematics, panel layouts, bills of material, wire lists, and terminal plans. The drawing functions include symbol libraries, macros, and automatic line breaking. Primary Promise customers include manufacturing companies, utilities, and other organizations with complex processes to control.

  7. Projective Dimension in Filtrated K-Theory

    DEFF Research Database (Denmark)

    Bentmann, Rasmus Moritz

    2013-01-01

    Under mild assumptions, we characterise modules with projective resolutions of length n∈N in the target category of filtrated K-theory over a finite topological space in terms of two conditions involving certain Tor -groups. We show that the filtrated K-theory of any separable C∗dash-algebra over...... any topological space with at most four points has projective dimension 2 or less. We observe that this implies a universal coefficient theorem for rational equivariant KK-theory over these spaces. As a contrasting example, we find a separable C∗dash-algebra in the bootstrap class over a certain five......-point space, the filtrated K-theory of which has projective dimension 3. Finally, as an application of our investigations, we exhibit Cuntz-Krieger algebras which have projective dimension 2 in filtrated K-theory over their respective primitive spectrum....

  8. Filtration aids in uranium ore processing

    International Nuclear Information System (INIS)

    Ford, H.L.; Levine, N.M.; Risdon, A.L.

    1975-01-01

    The patent describes a process whereby improved flocculation efficiency and filtration of carbonate leached uranium ore pulps are obtained by treating the filter feed slurry with an aqueous solution of hydroxyalkyl guar. (J.R.)

  9. Comparative evaluation of iohexol and inulin clearance for glomerular filtration rate determinations

    International Nuclear Information System (INIS)

    Lindblad, H.G.; Berg, U.B.

    1994-01-01

    The authors have evaluated iohexol as a filtration marker in 150 children. The clearance of iohexol was compared with that of inulin or with a formula clearance. The single-sample clearance of iohexol showed a good correlation with the clearance of inulin. The clearance of iohexol correlated well with the formula clearance. The optimal blood sampling time for iohexol clearance determinations appears to be between 120 and 180 min after injection, at least in patient with relatively normal filtration rates. It is concluded that iohexol clearance is an accurate method of determining the glomerular filtration rate in clinical practice. 25 refs., 5 figs

  10. On some Filtration Procedure for Jump Markov Process Observed in White Gaussian Noise

    OpenAIRE

    Khas'minskii, Rafail Z.; Lazareva, Betty V.

    1992-01-01

    The importance of optimal filtration problem for Markov chain with two states observed in Gaussian white noise (GWN) for a lot of concrete technical problems is well known. The equation for a posterior probability $\\pi(t)$ of one of the states was obtained many years ago. The aim of this paper is to study a simple filtration method. It is shown that this simplified filtration is asymptotically efficient in some sense if the diffusion constant of the GWN goes to 0. Some advantages of this proc...

  11. 40 CFR 141.719 - Additional filtration toolbox components.

    Science.gov (United States)

    2010-07-01

    ... taken from a surface water or GWUDI source. A cap, such as GAC, on a single stage of filtration is not... separate stage of filtration if both filtration stages treat entire plant flow taken from a surface water... 40 Protection of Environment 22 2010-07-01 2010-07-01 false Additional filtration toolbox...

  12. The promise and problems of non-physician practitioners in general surgery education: Results of a multi-center, mixed-methods study of faculty.

    Science.gov (United States)

    Coverdill, James E; Shelton, Jeff Scott; Alseidi, Adnan; Borgstrom, David C; Dent, Daniel L; Dumire, Russell; Fryer, Jonathan; Hartranft, Thomas H; Holsten, Steven B; Nelson, M Timothy; Shabahang, Mohsen M; Sherman, Stanley R; Termuhlen, Paula M; Woods, Randy J; Mellinger, John D

    2018-02-01

    Nurse Practitioners and Physician Assistants - called non-physician practitioners or NPPs - are common, but little is known about their educational promise and problems. General surgery faculty in 13 residency programs were surveyed (N = 279 with a 71% response rate) and interviewed (N = 43) about experiences with NPPs. The survey documents overall patterns and differences by program type and primary service; interviews point to deeper rationales and concerns. NPPs reduce faculty and resident workloads and teach residents. NPPs also reduce resident exposure to educationally valuable activities, and faculty sometimes round, make decisions, and operate with NPPs instead of residents. Interviews indicate that NPPs can overly reduce resident involvement in patient care, diminish resident responsibility and decision making, disrupt team dynamics, and compete for procedures. NPPs both enhance and hinder surgical education and highlight the need to more clearly articulate learning outcomes for residents and activities necessary to achieve those outcomes. Copyright © 2017 Elsevier Inc. All rights reserved.

  13. Ultra-filtration measurement using CT imaging technology

    International Nuclear Information System (INIS)

    Lu Junfeng; Lu Wenqiang

    2009-01-01

    As a functional unit in the hemodialysis process, dialyzer captured quite a few medical research interests since 1980s. In the design of dialyzer or in the ongoing hemodialysis process, to estimate the ultra-filtration amount of a dialyzer, the sideway loss of the running blood flow through hollow fibers or filtration channels should be measured. This further leads to the measurement of the blood flow inside the dialyzer. For this measurement, a non-invasive method is highly desired because of the high-dense bundled hollow fibers or packed channels inside the dialyzer. As non-invasive measurement tools, CT (Computed Tomography) technologies were widely used for tissue, bone, and cancerous clinical analyses etc .... Thus, in this paper, a CT system is adopted to predict the blood flow inside a hollow fiber dialyzer. In view of symmetric property of the hollow fiber dialyzer, the largest cutting plane that parallels to the cylindrical dialyzer was analyzed by the CT system dynamically. And then, a noninvasive image analysis method used to predict the ultra-filtration amount is proposed.

  14. Determination of the filtration velocities and mean velocity in ground waters using radiotracers

    International Nuclear Information System (INIS)

    Duran P, Oscar; Diaz V, Francisco; Heresi M, Nelida

    1994-01-01

    An experimental method to determine filtration, or, Darcy velocity and mean velocity in underground waters using radiotracers, is described. After selecting the most appropriate tracers, from 6 chemical compounds, to measure water velocity, a method to measure filtration velocity was developed. By fully labelling the water column with 2 radioisotopes, Br and tritium, almost identical values were obtained for the aquifer filtration velocity in the sounding S1. This value was 0.04 m/d. Field porosity was calculated at 11% and mean velocity at 0.37 m.d. With the filtration velocity value and knowing the hydraulic variation between the soundings S1 and S2 placed at 10 meters, field permeability was estimated at 2.4 x 10 m/s. (author)

  15. Organic iodide capture using a zeolite dry filtration

    International Nuclear Information System (INIS)

    Park, Sanggil; Sung, Joonyoung; Kim, Gi-ppeum; Lee, Jaeyoung

    2017-01-01

    An organic iodide, especially, methyl iodide (CH 3 I) would generated non-negligibly from a severe accident in a nuclear power plant. This CH 3 I will be dangerous for human when it was inhaled, it is highly toxic and causes a serious nerve disorder. Even it is a major contributor to a thyroid cancer. In order to prevent its environmental release, it is required to decontaminate using a filtration system. For the removal of CH 3 I from the release gases, wet-type is not ideal due to a high re-volatile characteristics of CH 3 I. It may become volatile after dissolving in a pool and forms CH 3 I again at the surface of water pool. Therefore, a dry-filtration should be installed to remove the CH 3 I. In this study, we preliminary investigate the characteristics of zeolite filtration methods for the removal of CH 3 I. We used both silver ion exchanged ZSM-5-zeolite (Ag+-ZSM-5) to study the effect of silver ion for the removal of iodine from CH 3 I. In summary, the CH 3 I capture tests using a silver ion exchanged zeolite was conducted in the coupled TGAGC test set-up. The mass change of the sample and concentration of CH 3 I were measured. The samples were investigated by the SEM/EDS to see its surface characteristics.

  16. EM Task 9 - Centrifugal membrane filtration

    International Nuclear Information System (INIS)

    Stepan, Daniel J.; Stevens, Bradley G.; Hetland, Melanie D.

    1999-01-01

    The overall project consists of several integrated research phases related to the applicability, continued development, demonstration, and commercialization of the SpinTek centrifugal membrane filtration process. Work performed during this reporting period consisted of Phase 2 evaluation of the SpinTek centrifugal membrane filtration technology and Phase 3, Technology Partnering. During Phase 1 testing conducted at the EERC using the SpinTek ST-IIL unit operating on a surrogate tank waste, a solids cake developed on the membrane surface. The solids cake was observed where linear membrane velocities were less than 17.5 ft/s and reduced the unobstructed membrane surface area up to 25%, reducing overall filtration performance. The primary goal of the Phase 2 research effort was to enhance filtration performance through the development and testing of alternative turbulence promoter designs. The turbulence promoters were designed to generate a shear force across the entire membrane surface sufficient to maintain a self-cleaning membrane capability and improve filtration efficiency and long-term performance. Specific Phase 2 research activities included the following: System modifications to accommodate an 11-in.-diameter, two-disk rotating membrane assembly; Development and fabrication of alternative turbulence promoter designs; Testing and evaluation of the existing and alternative turbulence promoters under selected operating conditions using a statistically designed test matrix; and Data reduction and analysis; The objective of Phase 3 research was to demonstrate the effectiveness of SpinTek's centrifugal membrane filtration as a pretreatment to remove suspended solids from a liquid waste upstream of 3M's WWL cartridge technology for the selective removal of technetium (Tc)

  17. Particle clogging in porous media. Filtration of a smectite solution

    Energy Technology Data Exchange (ETDEWEB)

    Richards, Tobias (Chalmers University of Technology, Goeteborg (Sweden))

    2010-01-15

    The goal of this project is to find out if it is possible for bentonite clay to self heal during leaching with deionized water. The investigation has focused on the formation of a filter cake made of accessory material from MX 80 and the separation of solid material when a smectite solution (1%) is pushed through the cake using a pressure difference of 5 bar. It was also in the scope of this project to design and build the necessary equipment for these experiments. In the literature review it was not found any example that the phenomenon of clogging has been used as a self-healing method previously. It was rather separated also between the clogging of a filter cake (deep bed filtration or cake filtration) and the filtration of colloidal particles. Probably because the latter are in such low concentrations in natural systems and the focus have mainly been in the transport properties of colloids within a filter cake or deep bed filter. An experimental equipment was designed and built. It consists of seven filtration cells that could operate in parallel. All of them are connected to the same source of pressure to ensure equal conditions. A system was also prepared to prevent air from dissolving in the solution because it could create an unwanted expansion in the filter cake due to lower solubility at lower pressure. The experiment showed good separation of smectite particles from the solution when it passed through the filter cake. In all tested cases, the separation was almost complete after long enough time, indicating that the cake has small enough pores to act as a geometrical hinder for the small particles. Comparison between the materials prepared at Chalmers University of Technology and at Clay Technology showed a very good agreement indicating similar properties of the produced smectite

  18. Particle clogging in porous media. Filtration of a smectite solution

    International Nuclear Information System (INIS)

    Richards, Tobias

    2010-01-01

    The goal of this project is to find out if it is possible for bentonite clay to self heal during leaching with deionized water. The investigation has focused on the formation of a filter cake made of accessory material from MX 80 and the separation of solid material when a smectite solution (1%) is pushed through the cake using a pressure difference of 5 bar. It was also in the scope of this project to design and build the necessary equipment for these experiments. In the literature review it was not found any example that the phenomenon of clogging has been used as a self-healing method previously. It was rather separated also between the clogging of a filter cake (deep bed filtration or cake filtration) and the filtration of colloidal particles. Probably because the latter are in such low concentrations in natural systems and the focus have mainly been in the transport properties of colloids within a filter cake or deep bed filter. An experimental equipment was designed and built. It consists of seven filtration cells that could operate in parallel. All of them are connected to the same source of pressure to ensure equal conditions. A system was also prepared to prevent air from dissolving in the solution because it could create an unwanted expansion in the filter cake due to lower solubility at lower pressure. The experiment showed good separation of smectite particles from the solution when it passed through the filter cake. In all tested cases, the separation was almost complete after long enough time, indicating that the cake has small enough pores to act as a geometrical hinder for the small particles. Comparison between the materials prepared at Chalmers University of Technology and at Clay Technology showed a very good agreement indicating similar properties of the produced smectite

  19. Vacuum distillation/vapor filtration water recovery

    Science.gov (United States)

    Honegger, R. J.; Neveril, R. B.; Remus, G. A.

    1974-01-01

    The development and evaluation of a vacuum distillation/vapor filtration (VD/VF) water recovery system are considered. As a functional model, the system converts urine and condensates waste water from six men to potable water on a steady-state basis. The system is designed for 180-day operating durations and for function on the ground, on zero-g aircraft, and in orbit. Preparatory tasks are summarized for conducting low gravity tests of a vacuum distillation/vapor filtration system for recovering water from urine.

  20. Statistical data filtration in neutron coincidence counting

    International Nuclear Information System (INIS)

    Beddingfield, D.H.; Menlove, H.O.

    1992-11-01

    We assessed the effectiveness of statistical data filtration to minimize the contribution of matrix materials in 200-ell drums to the nondestructive assay of plutonium. Those matrices were examined: polyethylene, concrete, aluminum, iron, cadmium, and lead. Statistical filtration of neutron coincidence data improved the low-end sensitivity of coincidence counters. Spurious data arising from electrical noise, matrix spallation, and geometric effects were smoothed in a predictable fashion by the statistical filter. The filter effectively lowers the minimum detectable mass limit that can be achieved for plutonium assay using passive neutron coincidence counting

  1. The Perspective of Riverbank Filtration in China

    Science.gov (United States)

    Li, J.; Teng, Y.; Zhai, Y.; Zuo, R.

    2014-12-01

    Sustainable drinking water supply can affect the health of people, and the surrounding ecosystems. According to statistics of the monitoring program of drinking water sources in 309 at or above prefecture level of China in 2013, the major pollutants index were total phosphorus, ammonia and manganese in surface drinking water sources, respectively, iron, ammonia and manganese in groundwater drinking water sources, respectively. More than 150 drinking water emergency environmental accidents happened since 2006, 52 of these accidents led to the disruption of water supply in waterworks, and a population of over ten million were affected. It indicated that there is a potential risk for people's health by the use of river water directly and it is necessary to require alternative techniques such as riverbank filtration for improving the drinking water quality. Riverbank filtration is an inexpensive natural process, not only smoothing out normal pollutant concentration found in surface water but also significantly reducing the risk from such emergency events as chemical spill into the river. Riverbank filtration technique has been used in many countries more than 100 years, including China. In China, in 1950s, the bank infiltration technique was first applied in northeast of China. Extensive bank infiltration application was conducted in 1980s, and more than 300 drinking water sources utilities bank infiltration established mainly near the Songhua River Basin, the Yellow River Basin, Haihe River Basin. However, the comparative lack of application and researches on riverbank filtration have formed critical scientific data gap in China. As the performance of riverbank filtration technique depend on not only the design and setting such as well type, pumping rate, but also the local hydrogeology and environmental properties. We recommend more riverbank filtration project and studies to be conducted to collect related significant environmental geology data in China

  2. Salt disposition alternatives filtration at SRTC

    International Nuclear Information System (INIS)

    Walker, B. W.; Hobbs, D.

    2000-01-01

    Several of the prospective salt disposition alternative technologies require a monosodium titanate (MST) contact to remove strontium and actinides from inorganic salt solution feedstock. This feedstock also contains sludge solids from waste removal operations and may contain defoamers added in the evaporator systems. Filtration is required to remove the sludge and MST solids before sending the salt solution for further processing. This report describes testing performed using the Parallel Theological Experimental Filter (PREF). The PREF contains two single tube Mott sintered metal crossflow filters. For this test one filter was isolated so that the maximum velocities could be achieved. Previous studies showed slurries of MST and sludge in the presence of sodium tetraphenylborate (NaTPB) were filterable since the NaTPB slurry formed a filter cake which aided in removing the smaller MST and sludge particles. Some of the salt disposition alternative technologies do not use NaTPB raising the question of how effective crossflow filtration is with a feed stream containing only sludge and MST. Variables investigated included axial velocity, transmembrane pressure, defoamer effects, and solids concentration (MST and sludge). Details of the tests are outlined in the technical report WSRC-RP-98-O0691. Key conclusions from this study are: (1) Severe fouling of the Mott sintered metal filter did not occur with any of the solutions filtered. (2) The highest fluxes, in the range of .46 to 1.02 gpm/f 2 , were obtained when salt solution decanted from settled solids was fed to the filter. These fluxes would achieve 92 to 204 gpm filtrate production for the current ITP filters. The filtrate fluxes were close to the flux of 0.42 gpm/f 2 reported for In Tank Precipitation Salt Solution by Morrisey. (3) For the range of solids loading studied, the filter flux ranged from .04 to .17 gpm/f 2 which would result in a filtrate production rate of 9 to 31 gpm for the current HP filter. (4

  3. Evaluating the effectiveness of heat-resistant cast steel filtration from the results of structure examinations

    Directory of Open Access Journals (Sweden)

    Asłanowicz M.

    2007-01-01

    Full Text Available Filtration guarantees castings characterised by high quality and free from any non-metallic inclusions, which are formed at the stage of melting and pouring of liquid metal. This article discusses the problem of the effectiveness of filtration process taking as an example heat-resistant cast steel poured into ceramic moulds. In investigations, foamed zircon filters made by FerroTerm Sp. z o.o. The effectiveness of filtration was described and examined using the results of metallographic examinations, including macro- and micro-structure examinations of metal and of cast metal/ceramic filter interface, and measurements of the content of non-metallic inclusions. The methods of investigations were presented, the obtained results were described, and relevant conclusions were drawn, all of them unmistakably indicating a very beneficial effect that filtration has on molten metal quality. Łódź, Poland, were used.

  4. Advanced Monitoring and Characterization of Biofouling in Gravity-driven Membrane Filtration

    KAUST Repository

    Wang, Yiran

    2016-05-01

    Gravity-driven membrane (GDM) filtration is one of the promising membrane bioreactor (MBR) technologies. It operates at a low pressure by gravity, requiring a minimal energy. Thus, it exhibits a great potential for a decentralized system, conducting household in developing and transition countries. Biofouling is a universal problem in almost all membrane filtration applications, leading to the decrease in flux or the increase in transmembrane pressure depending on different operation mode. Air scoring or regular membrane cleaning has been utilized for fouling mitigation, which requires increased energy consumption as well as complicated operations. Besides, repeating cleaning will trigger the deterioration of membranes and shorten their lifetime, elevating cost expenditures accordingly. In this way, GDM filtration stands out from conventional MBR technologies in a long-term operation with relative stable flux, which has been observed in many studies. The objective of this study was to monitor the biofilm development on a flat sheet membrane submerged in a GDM reactor with constant gravitational pressure. Morphology of biofilm layer in a fixed position was acquired by an in-situ and on-line OCT (optical coherence tomography) scanning at regular intervals for both visual investigation and structure analysis. The calculated thickness and roughness were compared to the variation of flux, fouling resistance and permeate quality, showing expected consistency. At the end of experiment, the morphology of entire membrane surface was scanned and recorded by OCT. Membrane autopsy was carried out for biofilm composition analysis by total organic carbon (TOC) and liquid chromatography with organic carbon detection (LC-OCD). In addition, biomass concentration was obtained by flow cytometer and adenosine tri-phosphate (ATP) method. The data of biofilm components indicated a homogeneous biofilm structure formed after a long-term running of the GDM system, based on the morphology

  5. Promising change, delivering continuity

    DEFF Research Database (Denmark)

    Lund, Jens Friis; Sungusia, Eliezeri; Mabele, Mathew Bukhi

    2017-01-01

    REDD+ is an ambition to reduce carbon emissions from deforestation and forest degradation in the Global South. This ambition has generated unprecedented commitment of political support and financial funds for the forest-development sector. Many academics and people-centered advocacy organizations...... have conceptualized REDD+ as an example of ‘‘green grabbing” and have voiced fears of a potential global rush for land and trees. In this paper we argue that, in practice and up until now, REDD+ resembles longstanding dynamics of the development and conservation industry, where the promise of change...... becomes a discursive commodity that is constantly reproduced and used to generate value and appropriate financial resources. We thus argue for a re-conceptualization of REDD+ as a conservation fad within the broader political economy of development and conservation. We derive this argument from a study...

  6. The Promise of Technology to Confront Dilemmas in Teacher Education: The Use of WebQuests in Problem-Based Methods Courses

    Science.gov (United States)

    Smith, Leigh K.; Draper, Roni Jo; Sabey, Brenda L.

    2005-01-01

    This qualitative study examined the use of WebQuests as a teaching tool in problem-based elementary methods courses. We explored the potential of WebQuests to address three dilemmas faced in teacher education: (a) modeling instruction that is based on current learning theory and research-based practices, (b) providing preservice teachers with…

  7. Filtration of engineered nanoparticles using porous membranes

    NARCIS (Netherlands)

    Trzaskus, Krzystof

    2016-01-01

    The research presented in this thesis aims at providing a better understanding of the fundamental aspects responsible for nanoparticle removal and fouling development during filtration of engineered nanoparticles. The emphasis is put on the role of interparticle interactions in the feed solution,

  8. Dynamic membrane filtration in tangential flow

    International Nuclear Information System (INIS)

    Anon.

    1993-01-01

    Oil-containing waste water is produced in many cleaning processes and also on production of compressed air. Dynamic membrane filtration in the tangential flow mode has proved effective in the treatment of these stable emulsions. The possible applications of ceramic membrane filters are illustrated for a variety of examples. (orig.) [de

  9. Filtration aids in uranium ore processing

    International Nuclear Information System (INIS)

    Ford, H.L.; Levine, N.M.; Risdon, A.R.

    1975-01-01

    A process of improving the filtration efficiency and separation of uranium ore pulps obtained by carbonate leaching of uranium ore which comprises treating said ore pulps with an aqueous solution of hydroxyalkyl guar selected from the group consisting of hydroxyethyl and hydroxypropyl guar in the amount of 0.1 and 2.0 pounds of hydroxyalkyl guar per ton of uranium ore

  10. Filtration engineering study to upgrade the ETF

    International Nuclear Information System (INIS)

    McDonald, F.N.N.

    1995-01-01

    Filtration technologies are evaluated which have potential to augment or upgrade the 200 Area Effluent Treatment Facility. The study was written in anticipation of treating future waste waters that have high fouling potentials. The Three ultrafilters judged to be capable of treating future waste waters are: hollow fiber, tubular, and centrifugal

  11. Water Filtration through Homogeneous Granulated Charge

    Directory of Open Access Journals (Sweden)

    A. M. Krautsou

    2005-01-01

    Full Text Available General relationship for calculation of water filtration through homogeneous granulated charge has been obtained. The obtained relationship has been compared with experimental data. Discrepancies between calculated and experimental values do not exceed 6 % throughout the entire investigated range.

  12. Organic micropollutant removal during river bank filtration

    NARCIS (Netherlands)

    Bertelkamp, C.

    2015-01-01

    This study investigated the factors influencing the main removal mechanisms (adsorption and biodegradation) for organic micropollutant (OMP) removal during river bank filtration (RBF) and the possibility of developing a predictive model of this process for OMP removal during RBF. Chapter 2 analysed

  13. The Promise and the Challenge of Technology-Facilitated Methods for Assessing Behavioral and Cognitive Markers of Risk for Suicide among U.S. Army National Guard Personnel.

    Science.gov (United States)

    Baucom, Brian R W; Georgiou, Panayiotis; Bryan, Craig J; Garland, Eric L; Leifker, Feea; May, Alexis; Wong, Alexander; Narayanan, Shrikanth S

    2017-03-31

    Suicide was the 10th leading cause of death for Americans in 2015 and rates have been steadily climbing over the last 25 years. Rates are particularly high amongst U.S. military personnel. Suicide prevention efforts in the military are significantly hampered by the lack of: (1) assessment tools for measuring baseline risk and (2) methods to detect periods of particularly heightened risk. Two specific barriers to assessing suicide risk in military personnel that call for innovation are: (1) the geographic dispersion of military personnel from healthcare settings, particularly amongst components like the Reserves; and (2) professional and social disincentives to acknowledging psychological distress. The primary aim of this paper is to describe recent technological developments that could contribute to risk assessment tools that are not subject to the limitations mentioned above. More specifically, Behavioral Signal Processing can be used to assess behaviors during interaction and conversation that likely indicate increased risk for suicide, and computer-administered, cognitive performance tasks can be used to assess activation of the suicidal mode. These novel methods can be used remotely and do not require direct disclosure or endorsement of psychological distress, solving two challenges to suicide risk assessment in military and other sensitive settings. We present an introduction to these technologies, describe how they can specifically be applied to assessing behavioral and cognitive risk for suicide, and close with recommendations for future research.

  14. The Promise and the Challenge of Technology-Facilitated Methods for Assessing Behavioral and Cognitive Markers of Risk for Suicide among U.S. Army National Guard Personnel

    Directory of Open Access Journals (Sweden)

    Brian R. W. Baucom

    2017-03-01

    Full Text Available Suicide was the 10th leading cause of death for Americans in 2015 and rates have been steadily climbing over the last 25 years. Rates are particularly high amongst U.S. military personnel. Suicide prevention efforts in the military are significantly hampered by the lack of: (1 assessment tools for measuring baseline risk and (2 methods to detect periods of particularly heightened risk. Two specific barriers to assessing suicide risk in military personnel that call for innovation are: (1 the geographic dispersion of military personnel from healthcare settings, particularly amongst components like the Reserves; and (2 professional and social disincentives to acknowledging psychological distress. The primary aim of this paper is to describe recent technological developments that could contribute to risk assessment tools that are not subject to the limitations mentioned above. More specifically, Behavioral Signal Processing can be used to assess behaviors during interaction and conversation that likely indicate increased risk for suicide, and computer-administered, cognitive performance tasks can be used to assess activation of the suicidal mode. These novel methods can be used remotely and do not require direct disclosure or endorsement of psychological distress, solving two challenges to suicide risk assessment in military and other sensitive settings. We present an introduction to these technologies, describe how they can specifically be applied to assessing behavioral and cognitive risk for suicide, and close with recommendations for future research.

  15. Surface-enhanced Raman scattering spectra revealing the inter-cultivar differences for Chinese ornamental Flos Chrysanthemum: a new promising method for plant taxonomy

    Directory of Open Access Journals (Sweden)

    Heng Zhang

    2017-10-01

    Full Text Available Abstract Background Flos Chrysanthemi, as a part of Chinese culture for a long history, is valuable for not only environmental decoration but also the medicine and food additive. Due to their voluminously various breeds and extensive distributions worldwide, it is burdensome to make recognition and classification among numerous cultivars with conventional methods which still rest on the level of morphologic observation and description. As a fingerprint spectrum for parsing molecular information, surface-enhanced Raman scattering (SERS could be a suitable candidate technique to characterize and distinguish the inter-cultivar differences at molecular level. Results SERS spectra were used to analyze the inter-cultivar differences among 26 cultivars of Chinese ornamental Flos Chrysanthemum. The characteristic peaks distribution patterns were abstracted from SERS spectra and varied from cultivars to cultivars. For the bands distributed in the pattern map, the similarities in general showed their commonality while in the finer scales, the deviations and especially the particular bands owned by few cultivars revealed their individualities. Since the Raman peaks could characterize specific chemical components, those diversity of patterns could indicate the inter-cultivar differences at the chemical level in fact. Conclusion In this paper, SERS technique is feasible for distinguishing the inter-cultivar differences among Flos Chrysanthemum. The Raman spectral library was built with SERS characteristic peak distribution patterns. A new method was proposed for Flos Chrysanthemum recognition and taxonomy.

  16. Study of water quality improvements during riverbank filtration at three midwestern United States drinking water utilities

    Science.gov (United States)

    Weiss, W.; Bouwer, E.; Ball, W.; O'Melia, C.; Lechevallier, M.; Arora, H.; Aboytes, R.; Speth, T.

    2003-04-01

    bank filtration. Artificial Recharge of Groundwater (J.H. Peters, editor). A.A. Balkema. Rotterdam, Netherlands; Brookfield, VT. Kuehn, W. &Mueller, U., 2000. Riverbank filtration: an overview. Jour. AWWA, 92:12:60. Leenheer, J.A., 1981. Comprehensive Approach to Preparative Isolation and Fractionation of Dissolved Organic Carbon from Natural Waters and Wastewaters. Environ. Sci. Technol., 15:5:578. Miettinen, I.T.; Martikainen, P.J.; &Vartiainen, T., 1994. Humus Transformation at the Bank Filtration Water Plant. Wat. Sci. Tech., 30:10:179. Ray, C.; Grischek, T.; Schubert, J.; Wang, J.Z.; &Speth, T.F., 2002. A perspective of riverbank filtration. Jour. AWWA, 94:4:149. Standard Methods for the Examination of Water and Wastewater, 1998 (20th ed.). APHA, AWWA, and WEF, Washington. Stuyfzand, P.J., 1998. Fate of pollutants during artificial recharge and bank filtration in the Netherlands. Artificial Recharge of Groundwater (J.H. Peters, editor). A.A. Balkema. Rotterdam, Netherlands; Brookfield, Vermont. Summers, R.S.; Hooper, S.M.; Shukairy, H.M.; Solarik, G.; &Owen, D., 1996. Assessing DBP Yield: Uniform Formation Conditions. Jour. AWWA, 88:6:80. Thurman, E.M. &Malcolm, R.L., 1981. Preparative Isolation of Aquatic Humic Substances. Environ. Sci. Technol., 15:4:463. Tufenkji, N.; Ryan, J.N.; &Elimelech, M., 2002. The Promise of Bank Filtration. Envir. Sci. &Technol., 36:21:423A.

  17. The Status and Promise of Advanced M&V: An Overview of “M&V 2.0” Methods, Tools, and Applications

    Energy Technology Data Exchange (ETDEWEB)

    Franconi, Ellen [Rocky Mountain Inst., Boulder, CO (United States); Gee, Matt [Univ. of Chicago, IL (United States); Goldberg, Miriam [DNV GL, Oslo (Norway); Granderson, Jessica [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Guiterman, Tim [EnergySavvy, Seattle, WA (United States); Li, Michael [U.S. Department of Energy (DOE), Baltimore, MD (United States); Smith, Brian Arthur [Pacific Gas and Electric, San Francisco, CA (United States)

    2017-04-11

    Advanced measurement and verification (M&V) of energy efficiency savings, often referred to as M&V 2.0 or advanced M&V, is currently an object of much industry attention. Thus far, however, there has been a lack of clarity about what techniques M&V 2.0 includes, how those techniques differ from traditional approaches, what the key considerations are for their use, and what value propositions M&V 2.0 presents to different stakeholders. The objective of this paper is to provide background information and frame key discussion points related to advanced M&V. The paper identifies the benefits, methods, and requirements of advanced M&V and outlines key technical issues for applying these methods. It presents an overview of the distinguishing elements of M&V 2.0 tools and of how the industry is addressing needs for tool testing, consistency, and standardization, and it identifies opportunities for collaboration. In this paper, we consider two key features of M&V 2.0: (1) automated analytics that can provide ongoing, near-real-time savings estimates, and (2) increased data granularity in terms of frequency, volume, or end-use detail. Greater data granularity for large numbers of customers, such as that derived from comprehensive implementation of advanced metering infrastructure (AMI) systems, leads to very large data volumes. This drives interest in automated processing systems. It is worth noting, however, that automated processing can provide value even when applied to less granular data, such as monthly consumption data series. Likewise, more granular data, such as interval or end-use data, delivers value with or without automated processing, provided the processing is manageable. But it is the combination of greater data detail with automated processing that offers the greatest opportunity for value. Using M&V methods that capture load shapes together with automated processing1 can determine savings in near-real time to provide stakeholders with more timely and

  18. Ultrasonic flow-through filtration of microparticles in a microfluidic channel using frequency sweep technique

    International Nuclear Information System (INIS)

    Seo, Dae Cheol; Ahn, Bong Young; Cho, Seung Hyun; Siddique, A. K. M. Ariful Haque; Kim, Cheol Gi

    2013-01-01

    Many studies have been conducted on the filtration of microparticles using the acoustic radiation force of ultrasonic standing wave. The present work concerns a flow-through particle filtration method by utilizing frequency varying ultrasound. The periodical frequency sweep of the ultrasonic standing wave translocates particles across a microchannel, where particles in fluid flow are filtrated without barriers. The present filtration technique in a microfluidic channel was proposed conceptually in the 1990s. However, its experimental realization on actual particles in a microfluidic channel has not been carried out in a notable way. Several sizes of polystyrene microspheres (10 µm to 90 µm) and silicon carbide (SiC) particles (37 µm) suspended in water were applied as a test sample. For filtration of those particles, a Y-branched microfluidic channel with one inlet and two outlets was made out of steel and acrylic as a form of modulized device. Ultrasound of a few MHz in band frequency (1.75 MHz to 3.05 MHz) was transmitted into one side of the channel wall to generate a standing wave field in fluid flow. The periodical frequency sweep operation showed successful filtration performance, whereby particles in water flowed into one outlet and purified water flowed into the other outlet of the Y branch of the channel.

  19. Optical measurements of lung microvascular filtration coefficient using polysulfone fibers.

    Science.gov (United States)

    Klaesner, J W; Roselli, R J; Evans, S; Pou, N A; Parker, R E; Tack, G; Parham, M

    1994-01-01

    Lung fluid balance, which is governed by the product of net transvascular pressure difference and lung filtration coefficient, can be altered in pulmonary diseases. A simple measurement of the lung filtration coefficient (Kfc) would be clinically useful and has been examined by several researchers. Current methods of determining Kfc include gravimetric measurement in isolated lungs and lymph node cannulation, neither of which can be extended to human use. Optical measurements of protein concentration changes in venous blood can be combined with pressure measurements to calculate Kfc. Blood, though, contains red corpuscles, which tend to absorb and scatter light, obscuring these optical measurements. In this study, an optical system was developed in which a polysulfone filter cartridge was used to remove red blood cells before the filtrate was passed through a spectrophotometer. Absorbance changes caused by changes in concentration of albumin labeled with Evans Blue were monitored at 620 nm after venous pressure was elevated by about 13 cm H2O. Optical measurements of Kfc averaged 0.401 +/- 0.074 (ml/min cm H2O 100 g DLW) for an isolated canine lung. Optical measurements of Kfc (0.363 +/- 0.120 ml/min cm H2O 100 g DLW) were made for the first time in an intact, closed chest sheep in which pulmonary pressure was altered by inflating a Foley balloon in the left atrium. We conclude that absorbance and scattering artifacts introduced by red blood cells can be eliminated by first filtering the blood through polysulfone fibers. Kfc measurements using the optical method are similar to values obtained by others using gravimetric methods. Finally, we have demonstrated that the technique can be used to estimate Kfc in an intact animal.

  20. OPTIMIZATION OF THE PROCESS OF DRYING THE FILTRATE DISTILLERY DREGS

    Directory of Open Access Journals (Sweden)

    A. A. Shevtsov

    2013-01-01

    Full Text Available The interactions of various factors affecting the process of drying the filtrate distillery dregs are investigated. Rational conditions for the process of drying the filtrate distillery dregs in a spray dryer are obtained.

  1. Synthesis of Alkanethiolate-Capped Metal Nanoparticles Using Alkyl Thiosulfate Ligand Precursors: A Method to Generate Promising Reagents for Selective Catalysis

    Directory of Open Access Journals (Sweden)

    Khin Aye San

    2018-05-01

    Full Text Available Evaluation of metal nanoparticle catalysts functionalized with well-defined thiolate ligands can be potentially important because such systems can provide a spatial control in the reactivity and selectivity of catalysts. A synthetic method utilizing Bunte salts (sodium S-alkylthiosulfates allows the formation of metal nanoparticles (Au, Ag, Pd, Pt, and Ir capped with alkanethiolate ligands. The catalysis studies on Pd nanoparticles show a strong correlation between the surface ligand structure/composition and the catalytic activity and selectivity for the hydrogenation/isomerization of alkenes, dienes, trienes, and allylic alcohols. The high selectivity of Pd nanoparticles is driven by the controlled electronic properties of the Pd surface limiting the formation of Pd–alkene adducts (or intermediates necessary for (additional hydrogenation. The synthesis of water soluble Pd nanoparticles using ω-carboxylate-S-alkanethiosulfate salts is successfully achieved and these Pd nanoparticles are examined for the hydrogenation of various unsaturated compounds in both homogeneous and heterogeneous environments. Alkanethiolate-capped Pt nanoparticles are also successfully synthesized and further investigated for the hydrogenation of various alkynes to understand their geometric and electronic surface properties. The high catalytic activity of activated terminal alkynes, but the significantly low activity of internal alkynes and unactivated terminal alkynes, are observed for Pt nanoparticles.

  2. Crossflow Filtration: EM-31, WP-2.3.6

    International Nuclear Information System (INIS)

    Duignan, M.; Nash, C.; Poirier, M.

    2011-01-01

    tests to evaluate methods to improve filter performance. With the proper use of filter flow conditions and filter enhancers, filter flow rates can be increased over rates currently realized today. Experiments that use non-radioactive simulants for actual waste always carry the inherent risk of not eliciting prototypic results; however, they will assist in focusing the scope needed to minimize radioactive testing and thus maximize safety. To that end this investigation has determined: (1) Waste simulant SB6 was found to be more challenging to filtration than a SRS Tank 8F simulant; (2) Higher solids concentration presents a greater challenge to filtration; (3) Filter cake is something that should be properly developed in initial filter operation; (4) Backpulsing is not necessary to maintain a good filter flux with salt wastes; (5) Scouring a filter without cleaning will lead to improved filter performance; (6) The presence of a filter cake can improve the solids separation by an order of magnitude as determined by turbidity; (7) A well developed cake with periodic scouring may allow a good filter flux to be maintained for long periods of time; and (8) Filtrate flux decline is reversible when the concentration of the filtering slurry drops and the filter is scoured.

  3. CROSSFLOW FILTRATION: EM-31, WP-2.3.6

    Energy Technology Data Exchange (ETDEWEB)

    Duignan, M.; Nash, C.; Poirier, M.

    2011-02-01

    tests to evaluate methods to improve filter performance. With the proper use of filter flow conditions and filter enhancers, filter flow rates can be increased over rates currently realized today. Experiments that use non-radioactive simulants for actual waste always carry the inherent risk of not eliciting prototypic results; however, they will assist in focusing the scope needed to minimize radioactive testing and thus maximize safety. To that end this investigation has determined: (1) Waste simulant SB6 was found to be more challenging to filtration than a SRS Tank 8F simulant; (2) Higher solids concentration presents a greater challenge to filtration; (3) Filter cake is something that should be properly developed in initial filter operation; (4) Backpulsing is not necessary to maintain a good filter flux with salt wastes; (5) Scouring a filter without cleaning will lead to improved filter performance; (6) The presence of a filter cake can improve the solids separation by an order of magnitude as determined by turbidity; (7) A well developed cake with periodic scouring may allow a good filter flux to be maintained for long periods of time; and (8) Filtrate flux decline is reversible when the concentration of the filtering slurry drops and the filter is scoured.

  4. Indexing Glomerular Filtration Rate to Body Surface Area

    DEFF Research Database (Denmark)

    Redal-Baigorri, Belén; Rasmussen, Knud; Heaf, James Goya

    2014-01-01

    BACKGROUND: Kidney function is mostly expressed in terms of glomerular filtration rate (GFR). A common feature is the expression as ml/min per 1.73 m(2) , which represents the adjustment of the individual kidney function to a standard body surface area (BSA) to allow comparison between individuals....... We investigated the impact of indexing GFR to BSA in cancer patients, as this BSA indexation might affect the reported individual kidney function. METHODS: Cross-sectional study of 895 adults who had their kidney function measured with (51) chrome ethylene diamine tetraacetic acid. Mean values of BSA...

  5. 40 CFR 141.174 - Filtration sampling requirements.

    Science.gov (United States)

    2010-07-01

    ... PROGRAMS (CONTINUED) NATIONAL PRIMARY DRINKING WATER REGULATIONS Enhanced Filtration and Disinfection... water system subject to the requirements of this subpart that provides conventional filtration treatment... 40 Protection of Environment 22 2010-07-01 2010-07-01 false Filtration sampling requirements. 141...

  6. 40 CFR 141.71 - Criteria for avoiding filtration.

    Science.gov (United States)

    2010-07-01

    ... PROGRAMS (CONTINUED) NATIONAL PRIMARY DRINKING WATER REGULATIONS Filtration and Disinfection § 141.71 Criteria for avoiding filtration. A public water system that uses a surface water source must meet all of...)(C)(iii), that filtration is required. A public water system that uses a ground water source under...

  7. 21 CFR 177.2910 - Ultra-filtration membranes.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 3 2010-04-01 2009-04-01 true Ultra-filtration membranes. 177.2910 Section 177... Components of Articles Intended for Repeated Use § 177.2910 Ultra-filtration membranes. Ultra-filtration membranes identified in paragraphs (a)(1), (a)(2), (a)(3), and (a)(4) of this section may be safely used in...

  8. The effect of filter cake viscoelasticity on filtration

    DEFF Research Database (Denmark)

    Christensen, Morten Lykkegaard

    , it is difficult to use the existing mathematical filtration models to simulate and optimise the filtration process. Activated sludge as well as synthetic model particles has been filtrated in this project. The study shows that compression of the formed filter cake is a time dependent process, and not only...

  9. Hanford phosphate precipitation filtration process evaluation

    International Nuclear Information System (INIS)

    Walker, B.W.; McCabe, D.J.

    1997-01-01

    The purpose of this filter study was to evaluate cross-flow filtration as effective solid-liquid separation technology for treating Hanford wastes, outline operating conditions for equipment, examine the expected filter flow rates, and determine proper cleaning. A proposed Hanford waste pre-treatment process uses sodium hydroxide at high temperature to remove aluminum from sludge. This process also dissolves phosphates. Upon cooling to 40 degrees centigrade the phosphates form a Na7(PO4)2F9H2O precipitate which must be removed prior to further treatment. Filter studies were conducted with a phosphate slurry simulant to evaluate whether 0.5 micron cross-flow sintered metal Mott filters can separate the phosphate precipitate from the wash solutions. The simulant was recirculated through the filters at room temperature and filtration performance data was collected

  10. Primary effluent filtration for coastal discharges

    Energy Technology Data Exchange (ETDEWEB)

    Cooper-Smith, G.D. [Yorkshire Water Services, Huddersfield (United Kingdom); Rundle, H. [The Capital Controls Group, Nottingham (United Kingdom)

    1998-12-31

    The use of a Tetra Deep Bed filter demonstration unit to treat primary effluent (Primary Effluent Filtration, PEF) was investigated. PEF proved capable of achieving the UWWTD primary standard, even when the primary stage performs poorly, but is not a cost-effective alternative to chemically assisted settlement. Results demonstrated that using a 1.5 to 2.2 mm grade medium, a filtration rate of 5 m/h, three backwashes a day and dosing 40 mg/l of PAXXL60 (a polyaluminium silicte) an average effluent quality of 20 mg/l BOD and 15 mgl/l total solid could be achieved. UV disinfection produced an effluent which complied with the Bathing Water Directive imperative requirement. A high enterovirus kill was also achieved. However, considerable additional work would be required before PEF could be considered suitable for full-scale applications. (orig.)

  11. Ultrasonic filtration of industrial chemical solutions

    Science.gov (United States)

    Cosma, T.

    1974-01-01

    The practical results obtained as a result of filtering industrial chemical solutions under continuous flow conditions with the aid of an ultrasonic filter are presented. The main part of the assembly consists of an ultrasonic generator with an output power of about 400 W and the filtration assembly, in which there is a magnetostrictive amplifier constructed for 20.5 kHz. In addition to ensuring a continuous flow of filtered solution, ultrasonic filters can be replaced or cleaned at intervals of time that are 8-10 times greater than in the case of mechanical filters. They yield considerably better results as far as the size of the filtered particles is concerned. The parameters on which filtration quality depends are also presented.

  12. Air filtration and indoor air quality

    DEFF Research Database (Denmark)

    Bekö, Gabriel

    2006-01-01

    Demands for better indoor air quality are increasing, since we spend most of our time indoors and we are more and more aware of indoor air pollution. Field studies in different parts of the world have documented that high percentage of occupants in many offices and buildings find the indoor air...... decent ventilation and air cleaning/air filtration, high indoor air quality cannot be accomplished. The need for effective air filtration has increased with increasing evidence on the hazardous effects of fine particles. Moreover, the air contains gaseous pollutants, removal of which requires various air...... cleaning techniques. Supply air filter is one of the key components in the ventilation system. Studies have shown that used ventilation filters themselves can be a significant source of indoor air pollution with consequent impact on perceived air quality, sick building syndrome symptoms and performance...

  13. High Temperature Particle Filtration Technology; TOPICAL

    International Nuclear Information System (INIS)

    Besmann, T.M.

    2001-01-01

    High temperature filtration can serve to improve the economic, environmental, and energy performance of chemical processes. This project was designed to evaluate the stability of filtration materials in the environments of the production of dimethyldichlorosilane (DDS). In cooperation with Dow Corning, chemical environments for the fluidized bed reactor where silicon is converted to DDS and the incinerator where vents are cornbusted were characterized. At Oak Ridge National Laboratory (ORNL) an exposure system was developed that could simulate these two environments. Filter samples obtained from third parties were exposed to the environments for periods up to 1000 hours. Mechanical properties before and after exposure were determined by burst-testing rings of filter material. The results indicated that several types of filter materials would likely perform well in the fluid bed environment, and two materials would be good candidates for the incinerator environment

  14. Enlargement of filtration with finance in view

    CERN Document Server

    Aksamit, Anna

    2017-01-01

    This volume presents classical results of the theory of enlargement of filtration. The focus is on the behavior of martingales with respect to the enlarged filtration and related objects. The study is conducted in various contexts including immersion, progressive enlargement with a random time and initial enlargement with a random variable.  The aim of this book is to collect the main mathematical results (with proofs) previously spread among numerous papers, great part of which is only available in French. Many examples and applications to finance, in particular to credit risk modelling and the study of asymmetric information, are provided to illustrate the theory. A detailed summary of further connections and applications is given in bibliographic notes which enables to deepen study of the topic.  This book fills a gap in the literature and serves as a guide for graduate students and researchers interested in the role of information in financial mathematics and in econometric science. A basic knowledge of...

  15. Osmosis, filtration and fracture of porous media

    International Nuclear Information System (INIS)

    Suarez Antola, R.

    2001-01-01

    Filtration was produced in a small scale physical model of a granular porous medium of cylindrical shape.The same volume flow was obtained either applying a difference in hydrostatic pressure or in osmotic pressure.In the first case a process of sustained erosion ending in an hydraulic short circuit was observed,while in the second case the material remained stable.This paradoxical strength behaviour is explained using some results from differential geometry,classical field theory and thermo-kinetic theory.The fracture process of a continuous matrix in a porous medium under the combined effect of filtration and external mechanical loads in then considered.The obtained results can be applied to the textural and compressive strength of wet concrete

  16. Aerosol filtration with metallic fibrous filters

    International Nuclear Information System (INIS)

    Klein, M.; Goossens, W.R.A.

    1983-01-01

    The filtration efficiency of stainless steel fibrous filters (BEKIPOR porous mats and sintered webs) is determined using submicronic monodisperse polystyrene aerosols. Lasers spectrometers are used for the aerosol measurements. The parameters varied are the fiber diameter, the number of layers, the aerosol diameter and the superficial velocity. Two selected types of filters are tested with polydisperse methylene blue aerosols to determine the effect of bed loading on the filter performance and to test washing techniques for the regeneration of the filter

  17. Diatomite releases silica during spirit filtration

    OpenAIRE

    Gómez Benítez, Juan; Gil Montero, María Luisa Almoraima; De la Rosa Fox, Nicolas; Alguacil, Marcos

    2014-01-01

    The purpose of this study was to ascertain whether diatomite is an inert filter aid during spirit filtration. Surely, any compound with a negative effect on the spirit composition or the consumer’s health could be dissolved. In this study different diatomites were treated with 36% vol. ethanol/water mixtures and the amounts and structures of the extracted compounds were determined. Furthermore, Brandy de Jerez was diatomite- and membrane-filtered at different temperatures and the silicon cont...

  18. Filtration system for nuclear power plant

    International Nuclear Information System (INIS)

    Otani, Takashi; Nakamizo, Hiroshi.

    1991-01-01

    The filtration system of the present invention comprises a filtering device incorporating ceramic filament element bundles, a pool return line for returning filtrates to a side banker pool or fuel storage pool, a waste sludge discharge line for discharging waste sludges captured in the filter elements by way of washing operation and a settling separation vessel. Ceramics of excellent radiation resistance and having an extremely thin multi-layered structure at the surface are used for the filter elements. Highly radioactive cruds captured at the surface of the elements by liquid passage are removed by supplying water or gas in a pulsative manner in the direction opposite to the liquid passage thereby cleaning the surface of the elements at a high speed. The thus removed high radioactive cruds are concentrically confined within the settling separation layer by gravitational settling separation. Thus, there is no more necessary for disposing the filtration element bundles after use, so that the amount of wastes can be reduced, the radiation dosage can be lowered and the facility can be simplified. (N.H.)

  19. Direct filtration of Biesbosch water and Algae and water treatment in the Netherlands : 3rd Direct Filtration Seminar

    NARCIS (Netherlands)

    Petrusevski, B.; Vlaski, A.; Van Breemen, A.N.; Alaerts, G.J.

    1993-01-01

    This presentation summarises basic information on direct filtration, and demonstrates the main research findings, related to the performance of simple in-line direct filtration. The results reported are part of a comprehensive ongoing research programm "Direct filtration of Biesbosch water"

  20. High efficiency filtration of liquid-metal-generated aerosols

    International Nuclear Information System (INIS)

    First, M.W.

    1977-01-01

    This paper will present data on filter performance for the range of sodium-containing aerorols that can result from large and small releases of hot metallic sodium into confined spaces containing air or special atmospheres and will compare the particle collection effectiveness, space and power requirements, service life, and disposal of the collected materials for the several options. Prompt reduction of in-vessel aerosols with methods that induce rapid coagulation and sedimentation by the application of violent turbulance, sonic energy, or electrostatic attraction; by aerosol scavenging with massive inert dust additions; and by a number of other innovative methods is of special interest because of their potential ability to bring down the aerosol cloud very rapidly and thereby to reduce vessel out-leakage drastically; as well as to relieve the particle load on filters. These methods will be examined as supplements to filtration methods for control of sodium-containing aerosols

  1. Filtration Efficiency of Functionalized Ceramic Foam Filters for Aluminum Melt Filtration

    Science.gov (United States)

    Voigt, Claudia; Jäckel, Eva; Taina, Fabio; Zienert, Tilo; Salomon, Anton; Wolf, Gotthard; Aneziris, Christos G.; Le Brun, Pierre

    2017-02-01

    The influence of filter surface chemistry on the filtration efficiency of cast aluminum alloys was evaluated for four different filter coating compositions (Al2O3—alumina, MgAl2O4—spinel, 3Al2O3·2SiO2—mullite, and TiO2—rutile). The tests were conducted on a laboratory scale with a filtration pilot plant, which facilitates long-term filtration tests (40 to 76 minutes). This test set-up allows the simultaneous use of two LiMCAs (before and after the filter) for the determination of the efficiency of inclusion removal. The four tested filter surface chemistries exhibited good thermal stability and mechanical robustness after 750 kg of molten aluminum had been cast. All four filter types exhibited a mean filtration efficiency of at least 80 pct. However, differences were also observed. The highest filtration efficiencies were obtained with alumina- and spinel-coated filter surfaces (>90 pct), and the complete removal of the largest inclusions (>90 µm) was observed. The efficiency was slightly lower with mullite- and rutile-coated filter surfaces, in particular for large inclusions. These observations are discussed in relation to the properties of the filters, in particular in terms of, for example, the surface roughness.

  2. A promise kept.

    Science.gov (United States)

    Harper, W James

    2010-01-01

    This article is largely biographical and relates to my experiences of the past 67 years in research and teaching, both of equal importance in my life. I was fortunate to start at the beginning of the development of instrumental methods of analysis and have eagerly embraced each new methodology as it became available. This paper is dedicated to all those students and colleagues who taught me much and whose efforts are mainly responsible for what has been accomplished in our work with food science and technology. The research focused primarily on trying to find out the "why" behind the problems that food, and especially the dairy products area, encountered over the past 65 years. The teaching has tried to foster thinking and problem solving.

  3. The Promises of Biology and the Biology of Promises

    DEFF Research Database (Denmark)

    Lee, Jieun

    2015-01-01

    commitments with differently imagined futures. I argue that promises are constitutive of the stem cell biology, rather than being derivative of it. Since the biological concept of stem cells is predicated on the future that they promise, the biological life of stem cells is inextricably intertwined...... patients’ bodies in anticipation of materializing the promises of stem cell biology, they are produced as a new form of biovaluable. The promises of biology move beyond the closed circuit of scientific knowledge production, and proliferate in the speculative marketplaces of promises. Part II looks at how...... of technologized biology and biological time can appear promising with the backdrop of the imagined intransigence of social, political, and economic order in the Korean society....

  4. Filtration of Oak Ridge National Laboratory simulated liquid low-level waste

    International Nuclear Information System (INIS)

    Fowler, V.L.; Hewitt, J.D.

    1989-08-01

    A method for disposal of Oak Ridge National Laboratory's (ORNL's) liquid low-level radioactive waste (LLLW) is being developed in which the material will be solidified in cement and stored in an aboveground engineered storage facility. The acceptability of the final waste form rests in part on the presence or absence of transuranic isotopes. Filtration methods to remove transuranic isotopes from the bulk liquid stored in the Melton Valley Storage Tanks (MVST) were investigated in this study. Initial batch studies using waste from MVST indicate that >99.9% of the transuranic isotopes can be removed from the bulk liquid by simple filtration. Bench-scale studies with a nonradioactive surrogate waste indicate that >99.5% of the suspended solids can be removed from the bulk liquid via inertial crossflow filtration. 4 refs., 3 figs., 11 tabs

  5. Filtration of aluminum alloys and its influence on mechanical properties and shape of eutectical silicium

    Directory of Open Access Journals (Sweden)

    M. Brůna

    2008-07-01

    Full Text Available Filtration during casting of high quality aluminum alloys belongs to main refining methods. Even when there are many years of experiences and experimental works on this subject, there are still some specific anomalies. While using ceramic filtration media during casting of aluminum alloys, almost in all experiments occurred increase of strength limit and atypical increase of extension. This anomaly was not explained with classical metallurgical methods, black-white contrast after surface etching neither with color surface etching. For that reason was used deep etching on REM. By using pressed ceramic filters, by studying morphology eutectical silicon was observed modification morphology of eutectical silicon, this explains increase extension after filtration. Pressed ceramic filters were used on experimental works. Casting was executed on hardenable alloy AlSi10MgMn.

  6. Approximate solutions to the deep bed filtration problem; Solucoes aproximadas para o problema de deposicao profunda

    Energy Technology Data Exchange (ETDEWEB)

    Silva, Julio M.; Marchesin, Dan [Instituto de Matematica Pura e Aplicada (IMPA), Rio de Janeiro, RJ (Brazil)

    2008-07-01

    The deep bed filtration problem is closely related to secondary oil recovery. In this work we derive explicit solutions to two filtration problems. The filtration function varies non-linearly with the Darcy speed and linearly with the deposition, but very little. The first solution is built by the method of perturbations and although it is only an approximation it is available in multiple symmetries, including the radial geometry used in the field. The main motivation is the validation of numerical methods. The second solution is exact but it is only available in the linear symmetry, i.e., laboratory geometry. We use it to verify the accuracy of the first solution, but it can also be used to simulate the deposition in experiments. (author)

  7. Measurement and characterization of filtration efficiencies for prefilter materials used in aerosol filtration

    International Nuclear Information System (INIS)

    Sciortino, J.

    1991-01-01

    In applications where the filtration of large quantities of mixed (liquid and solid) aerosols is desired, a multistage filtration system is often employed. This system consists of a prefilter, a High Efficiency Particulate Air (HEPA) filter, and any number of specialized filters particular to the filtration application. The prefilter removes liquids and any large particles from the air stream, keeping them from prematurely loading the HEPA filter downstream. The HEPA filter eliminates 99.97% of all particulates in the aerosol. The specialized filters downstream of the HEPA filter can be used to remove organic volatiles or other vapors. While the properties of HEPA filters have been extensively investigated, literature characterizing the prefilter is scarce. The purpose of this report is to characterize the efficiency of the prefilter as a function of particle size, nature of the particle (solid or liquid), and the gas flow rate across the face of the prefilter. 1 ref., 4 figs

  8. Transport of micropollutants in a riverbank filtration system

    Science.gov (United States)

    van Driezum, Inge; Oudega, Thomas; Reiner, Philipp; Zessner, Matthias; Farnleitner, Andreas; Blaschke, Paul

    2014-05-01

    Groundwater locations at alluvial backwaters are essential for public water supply. Riverbank filtration (RBF) systems are widely used as a means of obtaining public water supplies. Riverbank filtration is an effective way to remove micropollutants from the receiving surface water. The efficiency of the RBF system strongly depends on the residence time of the water in the aquifer and on the soil properties (Ray, 2011). In order to understand all bio- and geochemical processes within the hyporheic zone (e.g. the region were mixing of surface water and groundwater occurs), exchange rates and flow patterns need to be quantified. The main study area covers the porous groundwater aquifer study site (PGWA) - an urban floodplain extending on the left bank of the River Danube downstream of the City of Vienna. It is one of the main groundwater bodies in Austria. Groundwater quality in the PGWA is influenced by a combination of anthropogenic activities, industry, wastewater treatment plants, heavy precipitation events and floodings. The upper layer of the DPA is impermeable, preventing pollution originating from the surface. The upper layer consists of silt. The underlying confined aquifer consists of sand and gravel layers. Hydraulic conductivities range from 5 x 10-2 m/s up to 5 x 10-5 m/s. Underneath the aquifer are alternating sand an clay/silt layers. Samples are taken from two transects in the DPA. These transects consist of four piezometers in the first few meters of the groundwater aquifer. Several other piezometers are placed downstream from the river-groundwater interface. The behaviour of the micropollutants in the hyporheic zone can therefore be studied intensively. The transport behaviour of several micropollutants is modeled using carbamazepine (CBZ) and acesulfame (ACE) as natural tracers. Furthermore, temperature and electrical conductivity data was used for modeling. The micropollutants are measured using an in house developed online SPE-HPLC-MS/MS method

  9. Cake filtration modeling: Analytical cake filtration model and filter medium characterization

    Energy Technology Data Exchange (ETDEWEB)

    Koch, Michael

    2008-05-15

    Cake filtration is a unit operation to separate solids from fluids in industrial processes. The build up of a filter cake is usually accompanied with a decrease in overall permeability over the filter leading to an increased pressure drop over the filter. For an incompressible filter cake that builds up on a homogeneous filter cloth, a linear pressure drop profile over time is expected for a constant fluid volume flow. However, experiments show curved pressure drop profiles, which are also attributed to inhomogeneities of the filter (filter medium and/or residual filter cake). In this work, a mathematical filter model is developed to describe the relationship between time and overall permeability. The model considers a filter with an inhomogeneous permeability and accounts for fluid mechanics by a one-dimensional formulation of Darcy's law and for the cake build up by solid continuity. The model can be solved analytically in the time domain. The analytic solution allows for the unambiguous inversion of the model to determine the inhomogeneous permeability from the time resolved overall permeability, e.g. pressure drop measurements. An error estimation of the method is provided by rewriting the model as convolution transformation. This method is applied to simulated and experimental pressure drop data of gas filters with textile filter cloths and various situations with non-uniform flow situations in practical problems are explored. A routine is developed to generate characteristic filter cycles from semi-continuous filter plant operation. The model is modified to investigate the impact of non-uniform dust concentrations. (author). 34 refs., 40 figs., 1 tab

  10. Influence of Low-Temperature Plasma Treatment on The Liquid Filtration Efficiency of Melt-Blown PP Nonwovens in The Conditions of Simulated Use of Respiratory Protective Equipment

    Directory of Open Access Journals (Sweden)

    Majchrzycka Katarzyna

    2017-06-01

    Full Text Available Filtering nonwovens produced with melt-blown technology are one of the most basic materials used in the construction of respiratory protective equipment (RPE against harmful aerosols, including bio- and nanoaerosols. The improvement of their filtering properties can be achieved by the development of quasi-permanent electric charge on the fibres. Usually corona discharge method is utilized for this purpose. In the presented study, it was assumed that the low-temperature plasma treatment could be applied as an alternative method for the manufacturing of conventional electret nonwovens for the RPE construction. Low temperature plasma treatment of polypropylene nonwovens was carried out with various process gases (argon, nitrogen, oxygen or air in a wide range of process parameters (gas flow velocity, time of treatment and power supplied to the reactor electrodes. After the modification, nonwovens were evaluated in terms of filtration efficiency of paraffin oil mist. The stability of the modification results was tested after 12 months of storage and after conditioning at elevated temperature and relative humidity conditions. Moreover, scanning electron microscopy and ATR-IR spectroscopy were used to assess changes in surface topography and chemical composition of the fibres. The modification of melt-blown nonwovens with nitrogen, oxygen and air plasma did not result in a satisfactory improvement of the filtration efficiency. In case of argon plasma treatment, up to 82% increase of filtration efficiency of paraffin oil mist was observed in relation to untreated samples. This effect was stable after 12 months of storage in normal conditions and after thermal conditioning in (70 ± 3°C for 24 h. The use of low-temperature plasma treatment was proven to be a promising improvement direction of filtering properties of nonwovens used for the protection of respiratory tract against harmful aerosols.

  11. Numerical investigation of adhesion effects on solid particles filtration efficiency

    Science.gov (United States)

    Shaffee, Amira; Luckham, Paul; Matar, Omar K.

    2017-11-01

    Our work investigate the effectiveness of particle filtration process, in particular using a fully-coupled Computational Fluid Dynamics (CFD) and Discrete Element Method (DEM) approach involving poly-dispersed, adhesive solid particles. We found that an increase in particle adhesion reduces solid production through the opening of a wire-wrap type filter. Over time, as particle agglomerates continuously deposit on top of the filter, layer upon layer of particles is built on top of the filter, forming a particle pack. It is observed that with increasing particle adhesion, the pack height build up also increases and hence decreases the average particle volume fraction of the pack. This trend suggests higher porosity and looser packing of solid particles within the pack with increased adhesion. Furthermore, we found that the pressure drop for adhesive case is lower compared to non-adhesive case. Our results suggest agglomerating solid particles has beneficial effects on particle filtration. One important application of these findings is towards designing and optimizing sand control process for a hydrocarbon well with excessive sand production which is major challenge in oil and gas industry. Funding from PETRONAS and RAEng UK for Research Chair (OKM) gratefully acknowledged.

  12. Granular filtration for airborne particles : correlation between experiments and models

    Energy Technology Data Exchange (ETDEWEB)

    Golshahi, L.; Tan, Z. [Calgary Univ., AB (Canada). Schulich School of Engineering, Mechanical and Manufacturing Dept.; Abedi, J. [Calgary Univ., AB (Canada). Schulich School of Engineering, Chemical and Petroleum Engineering Dept.

    2009-10-15

    A new design for a packed bed granular filter was presented. The cylindrical packed bed was designed to filter particles in the range of approximately 10 nm to 15 {mu}m in diameter in different kinetic conditions and configurations. The aim of the study was to develop a precise empirical model to predict the filtration efficiency of the packed beds. A collision-type atomizer was used to generate polydisperse sodium chloride aerosol particles. The effect of flow rates was studied using a thermal mass flow meter. A regression analysis technique was used to determine the correlation between single granule and total packed bed efficiency for the entire granular filter. The experimental data were then compared with results obtained from the theoretical analysis. The least square method was used to correlate experimental data and to develop generalized equations for single granule efficiency. The study showed that the granular filter media has a high filtration efficiency for both micron and submicron particles. It was concluded that the effect of media thickness was more significant at higher flow rates than at lower flow rates. 10 refs., 3 figs.

  13. Limitation of releases and filtration by sand

    International Nuclear Information System (INIS)

    Schektman, N.

    1986-01-01

    In the highly hypothetic case of a severe reactor accident, it may lead to an increase of pressure within the containment and up to a value above the calculated pressure. A procedure is necessary in this case to maintain the integrity of the containment to prevent a release of radioactive products to the environment, while controlling in the best way releases. So, EDF and the CEA have developed a device of decompression-filtration of the containment atmosphere, using a free penetration of the containment and a sand box; the device and its operation constitute the U5 procedure [fr

  14. Good Filtrations and the Steinberg Square

    DEFF Research Database (Denmark)

    Kildetoft, Tobias

    that tensoring the Steinberg module with a simple module of restricted highest weight gives a module with a good filtration. This result was first proved by Andersen when the characteristic is large enough. In this dissertation, generalizations of those results, which are joint work with Daniel Nakano......, the socle completely determines how a Steinberg square decomposes. The dissertation also investigates the socle of the Steinberg square for a finite group of Lie type, again providing formulas which describe how to find the multiplicity of a simple module in the socle, given information about...

  15. Measurement of filtration efficiency of Nuclepore filters challenged with polystyrene latex nanoparticles: experiments and modeling

    International Nuclear Information System (INIS)

    Ling, Tsz Yan; Wang Jing; Pui, David Y. H.

    2011-01-01

    Membrane filtration has been demonstrated to be effective for the removal of liquid-borne nanoparticles (NPs). Such technique can be applied to purify and disinfect drinking water as well as remove NPs in highly pure chemicals used in the industries. This study aims to study the filtration process of a model membrane filter, the Nuclepore filter. Experiments were carried out using standard filtration tools and the nanoparticle tracking analysis (NTA) technique was used to measure particle (50–500 nm) concentration upstream and downstream of the filter to determine the filtration efficiency. The NTA technique has been calibrated using 150-nm polystyrene latex particles to determine its accuracy of particle concentration measurement. Measurements were found reliable within a certain concentration limit (about 10 8 –10 10 particles/cm 3 ), which is dependent on the camera settings during the measurement. Experimental results are comparable with previously published data obtained using the aerosolization method, validating the capability of the NTA technique. The capillary tube model modified from that developed for aerosol filtration was found to be useful to represent the experimental results, when a sticking coefficient of 0.15 is incorporated. This suggests that only 15% of the particle collisions with the filter results in successful attachment. The small sticking coefficient found can be explained by the unfavorable surface interactions between the particles and the filter medium.

  16. Design and Fabrication of Porous Yttria-Stabilized Zirconia Ceramics for Hot Gas Filtration Applications

    Science.gov (United States)

    Shahini, Shayan

    Hot gas filtration has received growing attention in a variety of applications over the past few years. Yttria-stabilized zirconia (YSZ) is a promising candidate for such an application. In this study, we fabricated disk-type porous YSZ filters using the pore forming procedure, in which poly methyl methacrylate (PMMA) was used as the pore-forming agent. After fabricating the pellets, we characterized them to determine their potential for application as gas filters. We investigated the effect of sintering temperature, polymer particle size, and polymer-to-ceramic ratio on the porosity, pore size, gas permeability, and Vickers hardness of the sintered pellets. Furthermore, we designed two sets of experiments to investigate the robustness of the fabricated pellets--i.e., cyclic heating/cooling and high temperature exposure. This study ushers in a robust technique to fabricate such porous ceramics, which have the potential to be utilized in hot gas filtration.

  17. Recent developments in powder resin precoat filtration for condensate clean-up at nuclear power plants with boiling water reactors

    International Nuclear Information System (INIS)

    Plaisier, L.

    1990-01-01

    The necessity to optimize condensate clean-up by means of powder resin precoat filtration has gained more and more importance. Not only the cost of powder resins themselves is important in this regard, but even more so the disposal of used resins and replaced filter elements. The factors influencing direct filtration efficiency, resin consumption, and service life of filter elements (powder resin quality; way of preparing the water - resin mixture; precoating method; filter design and piping; type and quality of filter elements, and filtration speed) are outlined. A method designed to reduce filtration speed as much as possible, i.e. to enlarge the filter surface while maintaining its volume and avoiding adverse effects, is described in detail and substantiated by data obtained from pilot tests. (orig./BBR) [de

  18. Sorption of polycyclic aromatic hydrocarbons (PAH) during the filtration of water samples

    International Nuclear Information System (INIS)

    Herbert, M.; Schueth, C.; Pyka, W.

    1992-01-01

    Filtration experiments were preformed for three selected polycyclic aromatic hydrocarbons (PAH-Fluorene, Fluoranthene and Benz(b)-fluoranthene) dissolved in water by varying filter materials, filter-pore sizes and filter equipment. The rate of recovery of PAH depended on the materials and methods applied. Organic filter materials showed a by far stronger sorption than inorganic materials. The losses for organic filters increased up to 100% with decreasing pore-size. The percentage loss was observed to increase with increasing octanol-water distribution coefficient (K OW ). Saturation tests revealed that the amount of water, necessary to saturate the filtration apparatus with and without filter-paper, also increased with the K OW . For BBF several liters would be necessary for saturation. It can be concluded, that the filtration of water samples, analysed for PAH, can lead to considerable errors in the analytical results, particularly for those PAH with log K OW larger than 5. (orig.)

  19. Potential study of bed filtration characteristics in impressed boreholes by radon tracer technique

    International Nuclear Information System (INIS)

    Litvinov, A.A.; Pinkenzon, D.B.; Makarov, M.S.; Vinarskij, M.S.

    1977-01-01

    Potential study of bed filtration characteristics in impressed boreholes by radon tracer method is shown. Effects recorded by radon tracer result from gamma radiation of short-living radon decay daughter products. During filtration of tracer through punched holes, cement stone, and rocks the products are deposited and cause a local effect for 2-3 hours. There is a shortage of short-living products in filtrated radon liquid and for some time (which is necessary for production of notable quantity of new decay products) it is practically not a gamma emitter. It is shown that the feature of effect formation governs the technique for well logging as well as interpretation of the results obtained

  20. Measurement of glomerular filtration rate by impulse synthesis: Clinical validation and optimization

    International Nuclear Information System (INIS)

    Palagi, B.; Verga, P.; Broggi, A.; Picozzi, R.; Villa, F.; Guzzini, F.; Cozzi, C.; Tomasi, A.

    1988-01-01

    Impulse synthesis is a technique which relies upon the logic of continuous infusion but extracts the clearance value from single-injection data by shifting and adding them until an asymptotic value is attained. This study has been aimed at validating and optimizing clinically the measurement of glomerular filtration rate by impulse synthesis. A single intravenous injection of 51 Cr-EDTA has been made in 32 patients and plasma activity monitored over the next 6 h. Glomerular filtration rate computed by a single-exponential fit method (GFR-SEF) has been shown to be significantly (p [de

  1. Simulation of the filtration mechanism of hyaluronic acid in total knee prosthesis

    International Nuclear Information System (INIS)

    Paolo, J Di; Berli, M E; Campana, D M; Ubal, S; Cardenes, L D

    2007-01-01

    Polyethylene (UHMWPE) wear in current knee prosthesis causes prosthesis loosening after no more than 15 years. In this work, a steady state one-dimensional lubrication model with non- Newtonian fluid, porous elastic layer on tibial component, ultra-filtration mechanism of fluid and some features of the surface roughness is studied through a numerical technique based on the Finite Element Method. The results show that the UHMWPE stiffness makes difficult the lubrication mechanism of the artificial joint and promotes abrasive and fatigue wear. Nevertheless, the use of compliant porous materials on the tibial component could reduce friction and wear. Moreover, the ultra-filtration mechanism promotes efficiency on the joint

  2. On the Problem of Filtration to an Imperfect Gallery in a Pressureless Bed

    Science.gov (United States)

    Bereslavskii, É. N.; Dudina, L. M.

    2018-01-01

    The problem of plane steady-state filtration in a pressureless bed to an imperfect gallery in the presence of evaporation from the flow free surface is considered. To study such type of flow, a mixed boundary-value problem of the theory of analytical functions is formulated and solved with application of the Polubarinova-Kochina method. Based on the model suggested, an algorithm for computing the discharge of the gallery and the ordinate of free surface emergence to the impermeable screen is developed. A detailed hydrodynamic analysis of the influence of all physical parameters of the model on the desired filtration characteristics is given.

  3. Dynamic optimization of a dead-end filtration trajectory: non-ideal cake filtration

    NARCIS (Netherlands)

    Blankert, B.; Kattenbelt, C.; Betlem, Bernardus H.L.; Roffel, B.

    2007-01-01

    A control strategy aimed at minimizing energy consumption is formulated for non-ideal dead-end cake filtration with an inside-out hollow fiber ultrafiltration membrane system. The non-ideal behavior was assumed to originate from cake compression, non-linear cake resistance and a variable pump

  4. Dynamic optimization of a dead-end filtration trajectory: Blocking filtration laws

    NARCIS (Netherlands)

    Blankert, B.; Betlem, Bernardus H.L.; Roffel, B.

    2006-01-01

    An operating model for dead-end membrane filtration is proposed based on the well-known blocking laws. The resulting model contains three parameters representing, the operating strategy, the fouling mechanism and the fouling potential of the feed. The optimal control strategy is determined by

  5. Variability of glomerular filtration rate estimation equations in elderly Chinese patients with chronic kidney disease

    Directory of Open Access Journals (Sweden)

    Liu X

    2012-10-01

    Full Text Available Xun Liu,1,2,* Mu-hua Cheng,3,* Cheng-gang Shi,1 Cheng Wang,1 Cai-lian Cheng,1 Jin-xia Chen,1 Hua Tang,1 Zhu-jiang Chen,1 Zeng-chun Ye,1 Tan-qi Lou11Division of Nephrology, Department of Internal Medicine, The Third Affiliated Hospital of Sun Yet-sun University, Guangzhou, China; 2College of Biology Engineering, South China University of Technology, Guangzhou, China; 3Department of Nuclear Medicine, The Third Affiliated Hospital of Sun Yet-sun University, Guangzhou, China *These authors contributed equally to this paperBackground: Chronic kidney disease (CKD is recognized worldwide as a public health problem, and its prevalence increases as the population ages. However, the applicability of formulas for estimating the glomerular filtration rate (GFR based on serum creatinine (SC levels in elderly Chinese patients with CKD is limited.Materials and methods: Based on values obtained with the technetium-99m diethylenetriaminepentaacetic acid (99mTc-DTPA renal dynamic imaging method, 319 elderly Chinese patients with CKD were enrolled in this study. Serum creatinine was determined by the enzymatic method. The GFR was estimated using the Cockroft–Gault (CG equation, the Modification of Diet in Renal Disease (MDRD equations, the Chronic Kidney Disease Epidemiology Collaboration (CKD-EPI equation, the Jelliffe-1973 equation, and the Hull equation.Results: The median of difference ranged from −0.3–4.3 mL/min/1.73 m2. The interquartile range (IQR of differences ranged from 13.9–17.6 mL/min/1.73 m2. Accuracy with a deviation less than 15% ranged from 27.6%–32.9%. Accuracy with a deviation less than 30% ranged from 53.6%–57.7%. Accuracy with a deviation less than 50% ranged from 74.9%–81.5%. None of the equations had accuracy up to the 70% level with a deviation less than 30% from the standard glomerular filtration rate (sGFR. Bland–Altman analysis demonstrated that the mean difference ranged from −3.0–2.4 mL/min/1.73 m2. However, the

  6. EM Task 9 - Centrifugal Membrane Filtration

    International Nuclear Information System (INIS)

    Stevens, B.G.; Stepan, D.J.; Hetland, M.D.

    1998-01-01

    This project is designed to establish the utility of a novel centrifugal membrane filtration technology for the remediation of liquid mixed waste streams at US Department of Energy (DOE) facilities in support of the DOE Environmental Management (EM) program. The Energy and Environmental Research Center (EERC) has teamed with SpinTek Membrane Systems, Inc., a small business and owner of the novel centrifugal membrane filtration technology, to establish the applicability of the technology to DOE site remediation and the commercial viability of the technology for liquid mixed waste stream remediation. The technology is a uniquely configured process that makes use of ultrafiltration and centrifugal force to separate suspended and dissolved solids from liquid waste streams, producing a filtered water stream and a low-volume contaminated concentrate stream. This technology has the potential for effective and efficient waste volume minimization, the treatment of liquid tank wastes, the remediation of contaminated groundwater plumes, and the treatment of secondary liquid waste streams from other remediation processes, as well as the liquid waste stream generated during decontamination and decommissioning activities

  7. Improved remote HEPA filtration development program

    International Nuclear Information System (INIS)

    Wilson, C.E. III.

    1987-03-01

    This paper presents a summary of the prototype development and hot cell mock-up testing program undertaken to adapt a commercial remote HEPA filter housing for use in the Process Facility Modification Project (PFMP). This program was initiated in response to the project design criteria and documentation that required the air from the hot cell environment to be exhausted through three stages of HEPA filtration. Due to the anticipated quantity of radioactive contamination captured by the first stage of filters, it was determined that the first stage would need to be located in a remotely operated and maintained shielded cell adjoining the primary hot cell areas. Commercially available remote filtration equipment was evaluated and candidate unit was identified, which could be developed into a suitable filter housing. A candidate unit was obtained from Flanders Filters, Inc. and a series of hot cell mock-up tests were identified in the 305 facility at the Hanford site. The results of these tests, and further interaction with the vendor, led to a prototype remote filter housing which satisfied most PFMP criteria and proved to be significantly superior to existing commercial units for remote operation/maintenance

  8. Diatomite releases silica during spirit filtration.

    Science.gov (United States)

    Gómez, J; Gil, M L A; de la Rosa-Fox, N; Alguacil, M

    2014-09-15

    The purpose of this study was to ascertain whether diatomite is an inert filter aid during spirit filtration. Surely, any compound with a negative effect on the spirit composition or the consumer's health could be dissolved. In this study different diatomites were treated with 36% vol. ethanol/water mixtures and the amounts and structures of the extracted compounds were determined. Furthermore, Brandy de Jerez was diatomite- and membrane-filtered at different temperatures and the silicon content was analysed. It was found that up to 0.36% by weight of diatomite dissolved in the aqueous ethanol and amorphous silica, in the form of hollow spherical microparticles, was the most abundant component. Silicon concentrations in Brandy de Jerez increased by up to 163.0% after contact with diatomite and these changes were more marked for calcined diatomite. In contrast, reductions of more than 30% in silicon concentrations were achieved after membrane filtration at low temperatures. Copyright © 2014 Elsevier Ltd. All rights reserved.

  9. Silica incorporated membrane for wastewater based filtration

    Science.gov (United States)

    Fernandes, C. S.; Bilad, M. R.; Nordin, N. A. H. M.

    2017-10-01

    Membrane technology has long been applied for waste water treatment industries due to its numerous advantages compared to other conventional processes. However, the biggest challenge in pressure driven membrane process is membrane fouling. Fouling decreases the productivity and efficiency of the filtration, reduces the lifespan of the membrane and reduces the overall efficiency of water treatment processes. In this study, a novel membrane material is developed for water filtration. The developed membrane incorporates silica nanoparticles mainly to improve its structural properties. Membranes with different loadings of silica nanoparticles were applied in this study. The result shows an increase in clean water permeability and filterability of the membrane for treating activated sludge, microalgae solution, secondary effluent and raw sewage as feed. Adding silica into the membrane matrix does not significantly alter contact angle and membrane pore size. We believe that silica acts as an effective pore forming agent that increases the number of pores without significantly altering the pore sizes. A higher number of small pores on the surface of the membrane could reduce membrane fouling because of a low specific loading imposed to individual pores.

  10. Filtration Systems Design for Universal Oils in Agricultural Tractors

    Directory of Open Access Journals (Sweden)

    R. Majdan

    2017-12-01

    Full Text Available Three filtration systems using the tractor hydraulic circuit were proposed and verified during the tractors operation. Using the tractor-implement hydraulic system and filter body with accessories the universally useful filtration systems were designed. The designed filtration systems are the second stage of universal oil filtration whereas the first stage is the standard tractor filter. The decrease in the content of iron reached the values 25.53 %, 32.95 % and 41.55 % and the average decrease in oil contamination characterized by average value of decrease in content of iron, copper and silicium reached values 24.3 %, 24.7 % and 35.53 % in dependence on the filtration system and an oil contamination level. The decrease in contamination level verified the ability of designed filtration systems for agricultural tractors.

  11. A study of dynamic filtration; Um estudo sobre filtracao dinamica

    Energy Technology Data Exchange (ETDEWEB)

    Girao, Joaquim Helder S [PETROBRAS, Natal, RN (Brazil). Distrito de Perfuracao da Bacia Potiguar. Div. de Tecnicas de Perfuracao

    1990-12-31

    The problems that cause cost increase such as: formation damage and borehole swelling or caving lead us to study the filtration of the liquid part of formation drilling fluid. With the aim of comparing static and dynamic filtration rates, we developed a modest dynamic filtration equipment, consisting of a modified API filter, connected to reservoir by means of a positive injection pump. We carried out various tests, and the results were set in charts and tables. Through these, it is possible to notice how the static and dynamic filtration curves come apart for a same pressure value. We also evaluated the effects of circulation speed, starch concentration and counter pressure. This paper does not include calculations or mathematical models accounting for filtrate invasion radii, but it demonstrates, for example, that cleaning circulation will cause lower filtration rates at lower flows. (author) 5 refs., 11 figs., 14 tabs.

  12. A study of dynamic filtration; Um estudo sobre filtracao dinamica

    Energy Technology Data Exchange (ETDEWEB)

    Girao, Joaquim Helder S. [PETROBRAS, Natal, RN (Brazil). Distrito de Perfuracao da Bacia Potiguar. Div. de Tecnicas de Perfuracao

    1989-12-31

    The problems that cause cost increase such as: formation damage and borehole swelling or caving lead us to study the filtration of the liquid part of formation drilling fluid. With the aim of comparing static and dynamic filtration rates, we developed a modest dynamic filtration equipment, consisting of a modified API filter, connected to reservoir by means of a positive injection pump. We carried out various tests, and the results were set in charts and tables. Through these, it is possible to notice how the static and dynamic filtration curves come apart for a same pressure value. We also evaluated the effects of circulation speed, starch concentration and counter pressure. This paper does not include calculations or mathematical models accounting for filtrate invasion radii, but it demonstrates, for example, that cleaning circulation will cause lower filtration rates at lower flows. (author) 5 refs., 11 figs., 14 tabs.

  13. Comparison of lysis-centrifugation with lysis-filtration and a conventional unvented bottle for blood cultures.

    OpenAIRE

    Gill, V J; Zierdt, C H; Wu, T C; Stock, F; Pizzo, P A; MacLowry, J D

    1984-01-01

    Evaluation of a commercially available lysis-centrifugation blood culture system (Isolator, DuPont Co., Wilmington, Del.) and a lysis-filtration blood culture system for 3,111 cultures showed that both methods had comparable recoveries (73 and 68%, respectively) of significant aerobic and facultatively anaerobic isolates. The unvented conventional blood culture bottle had a recovery rate of 59%. Although the lysis-centrifugation and lysis-filtration systems had comparable recoveries of pathog...

  14. Vibrating membrane filtration as improved technology for microalgae dewatering

    OpenAIRE

    Nurra, C.; Clavero, E.; Salvadó, J.; Torras, C.

    2014-01-01

    10.1016/j.biortech.2014.01.115 The effect of shear-enhanced filtration by vibratory process in microalgae dewatering is presented in this paper. The aim of this research was to investigate the technical performance and improvement of vibrating membrane filtration compared with conventional tangential cross-flow filtration in microalgae concentration. An industrial-scale available commercial set-up was used. Several membrane materials as polyethersulfone, polyacrylonitrile, etc., and mean ...

  15. A Laboratory Exercise for Visible Gel Filtration Chromatography Using Fluorescent Proteins

    Science.gov (United States)

    Zhang, Wenqiang; Cao, Yibin; Xu, Lishan; Gong, Jufang; Sun, Meihao

    2015-01-01

    Gel filtration chromatography (GFC) separates molecules according to size and is one of the most widely used methods for protein purification. Here, red fluorescent protein (RFP), green fluorescent protein (GFP), yellow fluorescent protein (YFP), cyan fluorescent protein (CFP), and/or their fusion proteins were prokaryotically expressed, purified,…

  16. Visualization and evaluation of flow during water filtration: Parameterization and sensitivity analysis

    Directory of Open Access Journals (Sweden)

    Bílek Petr

    2016-01-01

    Full Text Available This paper deals with visualization and evaluation of flow during filtration of water seeded by artificial microscopic particles. Planar laser induced fluorescence (PLIF is a wide spread method for visualization and non-invasive characterization of flow. However the method uses fluorescent dyes or fluorescent particles in special cases. In this article the flow is seeded by non-fluorescent monodisperse polystyrene particles with the diameter smaller than one micrometer. The monodisperse sub-micron particles are very suitable for testing of textile filtration materials. Nevertheless non-fluorescent particles are not useful for PLIF method. A water filtration setup with an optical access to the place, were a tested filter is mounted, was built and used for the experiments. Concentration of particles in front of and behind the tested filter in a laser light sheet measured is and the local filtration efficiency expressed is. The article describes further progress in the measurement. It was carried out sensitivity analysis, parameterization and performance of the method during several simulations and experiments.

  17. The Effect of Ventilation, Filtration and Passive Sorption on Indoor Air Quality in Museum Storage Rooms

    DEFF Research Database (Denmark)

    Ryhl-Svendsen, M.; Clausen, Geo

    2009-01-01

    in reducing nitrogen dioxide. Increased ventilation rates were expected to dilute internally generated pollutants, but ambiguous results imply that the emission rate of organic acids may also vary Recirculation/filtration was generally, the most efficient method. A cautious conclusion is that a combination...

  18. Assessment of glomerular filtration rate measurement with plasma sampling: a technical review.

    Science.gov (United States)

    Murray, Anthony W; Barnfield, Mark C; Waller, Michael L; Telford, Tania; Peters, A Michael

    2013-06-01

    This article reviews available radionuclide-based techniques for glomerular filtration rate (GFR) measurement, focusing on clinical indications for GFR measurement, ideal GFR radiopharmaceutical tracer properties, and the 2 most common tracers in clinical use. Methods for full, 1-compartment, and single-sample renal clearance characterization are discussed. GFR normalization and the role of GFR measurement in chemotherapy dosing are also considered.

  19. Results of Laboratory Tests of the Filtration Characteristics of Clay-Cement Concrete

    Energy Technology Data Exchange (ETDEWEB)

    Sol’skii, S. V., E-mail: solskiysv@vniig.ru; Lopatina, M. G., E-mail: LoptainaMG@vniig.ru; Legina, E. E.; Orishchuk, R. N.; Orlova, N. L. [B. E. Vedeneev All-Russia Research Institute of Hydraulic Engineering (VNIIG) (Russian Federation)

    2017-01-15

    Laboratory studies of the filtration characteristics of clay-cement concrete materials for constructing filtering diaphragms of earth dams by the method of secant piles are reported. Areas for further study aimed at improving the quality of construction, increasing operational safety, and developing a standards base for the design, construction, and operation of these systems are discussed.

  20. Filtration in the Use of Individual Water Purification Devices

    National Research Council Canada - National Science Library

    Lundquist, Arthur; Clarke, Steven; Bettin, William

    2006-01-01

    .... Understanding the ability of filtration to reduce disease-causing microorganisms in water is important in protecting Soldiers, who are considering using this technology, from acute health threats...

  1. Novel water filtration of saline water in the outermost layer of mangrove roots.

    Science.gov (United States)

    Kim, Kiwoong; Seo, Eunseok; Chang, Suk-Kyu; Park, Tae Jung; Lee, Sang Joon

    2016-02-05

    The scarcity of fresh water is a global challenge faced at present. Several desalination methods have been suggested to secure fresh water from sea water. However, conventional methods suffer from technical limitations, such as high power consumption, expensive operating costs, and limited system durability. In this study, we examined the feasibility of using halophytes as a novel technology of desalinating high-concentration saline water for long periods. This study investigated the biophysical characteristics of sea water filtration in the roots of the mangrove Rhizophora stylosa from a plant hydrodynamic point of view. R. stylosa can grow even in saline water, and the salt level in its roots is regulated within a certain threshold value through filtration. The root possesses a hierarchical, triple layered pore structure in the epidermis, and most Na(+) ions are filtered at the first sublayer of the outermost layer. The high blockage of Na(+) ions is attributed to the high surface zeta potential of the first layer. The second layer, which is composed of macroporous structures, also facilitates Na(+) ion filtration. This study provides insights into the mechanism underlying water filtration through halophyte roots and serves as a basis for the development of a novel bio-inspired desalination method.

  2. SU-F-I-76: Fluoroscopic X-Ray Beam Profiles for Spectra Incorporating Copper Filtration

    Energy Technology Data Exchange (ETDEWEB)

    Wunderle, K [Cleveland Clinic Foundation, Cleveland, OH (United States); Wayne State University School of Medicine, Detroit, MI (United States); Godley, A; Shen, Z; Dong, F [Cleveland Clinic Foundation, Cleveland, OH (United States); Rakowski, J [Wayne State University School of Medicine, Detroit, MI (United States)

    2016-06-15

    Purpose: The purpose of this investigation is to characterize and quantify X-ray beam profiles for fluoroscopic x-ray beam spectra incorporating spectral (copper) filtration. Methods: A PTW (Freiburg, Germany) type 60016 silicon diode detector and PTW MP3 water tank were used to measure X-ray beam profiles for 60, 80, 100 and 120 kVp x-ray beams at five different copper filtration thicknesses ranging from 0–0.9 mm at 22 and 42 cm fields of view and depths of 1, 5, and 10 cm in both the anode-cathode axis (inplane) and cross-plane directions. All measurements were acquired on a Siemens (Erlangen, Germany) Artis ZeeGo fluoroscope inverted from the typical orientation providing an x-ray beam originating from above the water surface with the water level set at 60 cm from the focal spot. Results: X-ray beam profiles for beam spectra without copper filtration compared well to previously published data by Fetterly et al. [Med Phys, 28, 205 (2001)]. Our data collection benefited from the geometric orientation of the fluoroscope, providing a beam perpendicular to the tank water surface, rather than through a thin side wall as did the previously mentioned study. Profiles for beams with copper filtration were obtained which have not been previously investigated and published. Beam profiles in the anode-cathode axis near the surface and at lower x-ray energy exhibited substantial heel effect, which became less pronounced at greater depth. At higher energy with copper filtration in the beam, the dose falloff out-of-field became less pronounced, as would be anticipated given higher scatter photon energy. Conclusion: The x-ray beam profile data for the fluoroscopic x-ray beams incorporating copper filtration are intended for use as reference data for estimating doses to organs or soft tissue, including fetal dose, involving similar beam qualities or for comparison with mathematical models.

  3. Correlations of filtration flux enhanced by electric fields in crossflow microfiltration

    Energy Technology Data Exchange (ETDEWEB)

    Okada, K.; Nagase, Y. [Kurashiki University of Science and the Arts, Okayama (Japan). Department of Chemical Technology; Ohnishi, Y.; Nishihan, A.; Akagi, Y. [Okayama University of Science, Okayama (Japan). Department of Applied Chemistry

    1997-12-01

    The steady state filtration flux in electrically-enhanced crossflow microfiltration is estimated using a correlation equation proposed for several kinds of suspensions. Baker`s yeast and Rhodotorula glutinis were used as model samples of microbial cells, and PMMA particles were used as samples of non-living solids. Application of the electric field in crossflow microfiltration is a useful method for improving the filtration flux of these samples. High flux levels for the cells were achieved when an electric field above 3000 V/m was applied. The effect of the electric field in increasing the filtration flux of the steady state was analyzed theoretically using a force balance model where the viscous drag force, F{sub J}, the electrophoretic force, F{sub E}, and the re-entraining force, F{sub B}, were considered to act on a particle on the membrane surface under a steady state of filtration, respectively. From force balance analysis, it is found that on application of an electric field, the electro-osmotic effect can be neglected in the present study, so that the filtration flux of the steady state, J{sub ES}, can be presented by, J{sub ES}=U{sub EP}E+J{sub OS} where U{sub EP} is the electrophoretic mobility of particles and E is the electric field applied. J{sub OS} is the filtration flux in the absence of an electric field, which is correlated with the operating parameters for suspensions tested. 22 refs., 7 figs., 1 tab.

  4. Political Reputations and Campaign Promises

    OpenAIRE

    Aragones, Enriqueta; Palfrey, Thomas R.; Postlewaite, Andrew

    2006-01-01

    We analyze conditions under which candidates' reputations may affect voters' beliefs over what policy will be implemented by the winning candidate of an election. We develop a model of repeated elections with complete information in which candidates are purely ideological. We analyze an equilibrium in which voters' strategies involve a credible threat to punish candidates who renege on their campaign promises and in which all campaign promises are believed by voters and honored by candidates....

  5. Experiments on high efficiency aerosol filtration

    International Nuclear Information System (INIS)

    Mazzini, M.; Cuccuru, A.; Kunz, P.

    1977-01-01

    Research on high efficiency aerosol filtration by the Nuclear Engineering Institute of Pisa University and by CAMEN in collaboration with CNEN is outlined. HEPA filter efficiency was studied as a function of the type and size of the test aerosol, and as a function of flowrate (+-50% of the nominal value), air temperature (up to 70 0 C), relative humidity (up to 100%), and durability in a corrosive atmosphere (up to 140 hours in NaCl mist). In the selected experimental conditions these influences were appreciable but are not sufficient to be significant in industrial HEPA filter applications. Planned future research is outlined: measurement of the efficiency of two HEPA filters in series using a fixed particle size; dependence of the efficiency on air, temperatures up to 300-500 0 C; performance when subject to smoke from burning organic materials (natural rubber, neoprene, miscellaneous plastics). Such studies are relevant to possible accidental fires in a plutonium laboratory

  6. 40 CFR 141.171 - Criteria for avoiding filtration.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 22 2010-07-01 2010-07-01 false Criteria for avoiding filtration. 141.171 Section 141.171 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) WATER PROGRAMS (CONTINUED) NATIONAL PRIMARY DRINKING WATER REGULATIONS Enhanced Filtration and Disinfection...

  7. Scaling and particulate fouling in membrane filtration systems

    NARCIS (Netherlands)

    Boerlage, S.F.E.

    2001-01-01

    In the last decade, pressure driven membrane filtration processes; reverse osmosis, nano, ultra and micro-filtration have undergone steady growth. Drivers for this growth include desalination to combat water scarcity and the removal of various material from water to comply with increasingly

  8. Rotating Ceramic Water Filter Discs System for Water Filtration

    Directory of Open Access Journals (Sweden)

    Riyadh Z. Al Zubaidy

    2017-04-01

    Full Text Available This work aimed to design, construct and operate a new laboratory scale water filtration system. This system was used to examine the efficiency of two ceramic filter discs as a medium for water filtration. These filters were made from two different ceramic mixtures of local red clay, sawdust, and water. The filtration system was designed with two rotating interfered modules of these filters. Rotating these modules generates shear force between water and the surfaces of filter discs of the filtration modules that works to reduce thickness of layer of rejected materials on the filters surfaces. Each module consists of seven filtration units and each unit consists of two ceramic filter discs. The average measured hydraulic conductivity of the first module was 13.7mm/day and that for the second module was 50mm/day. Results showed that the water filtration system can be operated continuously with a constant flow rate and the filtration process was controlled by a skin thin layer of rejected materials. The ceramic water filters of both filtration modules have high removal efficiency of total suspended solids up to 100% and of turbidity up to 99.94%.

  9. Life Support Filtration System Trade Study for Deep Space Missions

    Science.gov (United States)

    Agui, Juan H.; Perry, Jay L.

    2017-01-01

    The National Aeronautics and Space Administrations (NASA) technical developments for highly reliable life support systems aim to maximize the viability of long duration deep space missions. Among the life support system functions, airborne particulate matter filtration is a significant driver of launch mass because of the large geometry required to provide adequate filtration performance and because of the number of replacement filters needed to a sustain a mission. A trade analysis incorporating various launch, operational and maintenance parameters was conducted to investigate the trade-offs between the various particulate matter filtration configurations. In addition to typical launch parameters such as mass, volume and power, the amount of crew time dedicated to system maintenance becomes an increasingly crucial factor for long duration missions. The trade analysis evaluated these parameters for conventional particulate matter filtration technologies and a new multi-stage particulate matter filtration system under development by NASAs Glenn Research Center. The multi-stage filtration system features modular components that allow for physical configuration flexibility. Specifically, the filtration system components can be configured in distributed, centralized, and hybrid physical layouts that can result in considerable mass savings compared to conventional particulate matter filtration technologies. The trade analysis results are presented and implications for future transit and surface missions are discussed.

  10. Vibrating membrane filtration as improved technology for microalgae dewatering.

    Science.gov (United States)

    Nurra, Claudia; Clavero, Ester; Salvadó, Joan; Torras, Carles

    2014-04-01

    The effect of shear-enhanced filtration by vibratory process in microalgae dewatering is presented in this paper. The aim of this research was to investigate the technical performance and improvement of vibrating membrane filtration compared with conventional tangential cross-flow filtration in microalgae concentration. An industrial-scale available commercial set-up was used. Several membrane materials as polyethersulfone, polyacrylonitrile, etc., and mean pore sizes (from 7000Da to 0.2μm) were tested and compared in both filtration set-ups. Experiments were carried-out with Nannochloropsis gaditana and Phaeodactylum tricornutum microalgae. It has been demonstrated that, even if the choice of the membrane depends on its cut-off, its material and the type of microalgae filtrated, dynamic filtration is always the best technology over a conventional one. If with conventional filtration permeability values were in the vicinity of 10L/h/m(2)/bar in steady state phase, with dynamic filtration these values increased to 30L/h/m(2)/bar or more. Copyright © 2014 Elsevier Ltd. All rights reserved.

  11. Presenting a mapping method based on fuzzy Logic and TOPSIS multi criteria decision-making methods to detect promising porphyry copper mineralization areas in the east of the Sarcheshmeh copper metallogenic district

    Directory of Open Access Journals (Sweden)

    Shokouh Riahi

    2017-11-01

    Full Text Available Introduction The growing demand for base metals such as iron, copper, lead and zinc on the one hand and the diminishing of surficial and shallow resources of these elements on the other hand have forced explorationists to focus on detecting deep deposits of these metals. As a result, the discovery of such deep deposits requires more advanced and sophisticated methods in the course of preliminary prospecting stages. Since the discovery of new deposits is getting to be increasingly difficult, deploying new prospecting technologies that employ more deposit attributes in the course of combining exploratory evidence may reduce the exploration costs with lower uncertainties. In the past two decades, a number of new data mining and integrating approaches capable of incorporating direct and indirect mineralization indicators, based on expert knowledge, data, or a combination of both, have been proposed Bonham-Carter, 1994(. In the first step, the input exploratory data layers are corrected and validated through applying some statistical pre-processing algorithms such as background and outlier removal methods. In order to detect a mineralization occurrence, it is necessary to find the proper exploratory geological, geochemical and geophysical data layers which have direct or indirect associations with the governing mineralization followed by constructing these models in an appropriate GIS platform (Malkzewski, 1999. Due to the imperfect available data and a number of unknown parameters affecting the mineralization process, the application of conventional GIS integration methods such as Boolean or weighted overlay or even fuzzy logic methods alone may not produce appropriate results, pointing to a need for deploying multi-criteria decision-making methods such as TOPSIS. In the present study, the pre-processed exploratory data including geological, remotely sensed geophysical and geochemical imagery were used to detect favorable mineralization zones

  12. Filtration behaviors of rod-shaped bacterial broths in unsteady-state phase of cross-flow filtration

    Energy Technology Data Exchange (ETDEWEB)

    Tanaka, T.; Usui, K.; Koda, K.; Nakanishi, K. [Okayama University, Okayama (Japan). Faculty of Engineering

    1996-12-20

    Filtration behaviors in the unsteady-state phase of crossflow filtration of broths of Bacillus subtilis, Escherichia coli, and Lactobacillus delbrueckii, which are rod-shaped, were studied from the viewpoint of the changes in the specific resistance and in the structure of the microbial cake formed on the membrane surface. The permeation flux followed the cake filtration law at the initial stage of the crossflow filtration of the broths of B. subtilis and E. coli, where the cells deposited randomly on the membrane. In the case of the crossflow filtration of a L. delbrueckii broth, the period of random deposition was shorter. The specific resistance for the cake formed at the initial stage agreed with that measured in dead-end filtration. Then, the specific resistance started to increase in comparison with that measured in dead-end filtration due to shear-induced arrangement of the cells. The extent of the increase in specific resistance became higher and the time taken to start the cell arrangement became shorter with increasing circulation flow rate. The increase in specific resistance due to the shear-induced arrangement was more appreciable in the crossflow filtration of the broth of L. delbrueckii than that of B. subtilis and E. coli. The average permeation flux was increased considerably by applying periodical backwashing with appropriate time intervals. The permeation flux was well predicted by the cake filtration law, since the cells deposited in a way similar to that for dead-end filtration during a sufficiently short period of crossflow filtration in a backwashing mode. 21 refs., 11 figs.

  13. DUST FILTRATION BY PLANET-INDUCED GAP EDGES: IMPLICATIONS FOR TRANSITIONAL DISKS

    Energy Technology Data Exchange (ETDEWEB)

    Zhu Zhaohuan; Dong Ruobing [Department of Astrophysical Sciences, 4 Ivy Lane, Peyton Hall, Princeton University, Princeton, NJ 08544 (United States); Nelson, Richard P. [Astronomy Unit, Queen Mary University of London, Mile End Road, London E1 4NS (United Kingdom); Espaillat, Catherine [Center for Astrophysics, 60 Garden Street, Cambridge, MA 02138 (United States); Hartmann, Lee, E-mail: zhzhu@astro.princeton.edu, E-mail: rdong@astro.princeton.edu, E-mail: lhartm@umich.edu, E-mail: r.p.nelson@qmul.ac.uk, E-mail: cespaillat@cfa.harvard.edu [Department of Astronomy, University of Michigan, 500 Church St., Ann Arbor, MI 48109 (United States)

    2012-08-10

    By carrying out two-dimensional two-fluid global simulations, we have studied the response of dust to gap formation by a single planet in the gaseous component of a protoplanetary disk-the so-called dust filtration mechanism. We have found that a gap opened by a giant planet at 20 AU in an {alpha} = 0.01, M-dot =10{sup -8} M{sub Sun} yr{sup -1} disk can effectively stop dust particles larger than 0.1 mm drifting inward, leaving a submillimeter (submm) dust cavity/hole. However, smaller particles are difficult to filter by a gap induced by a several M{sub J} planet due to (1) dust diffusion and (2) a high gas accretion velocity at the gap edge. Based on these simulations, an analytic model is derived to understand what size particles can be filtered by the planet-induced gap edge. We show that a dimensionless parameter T{sub s} /{alpha}, which is the ratio between the dimensionless dust stopping time and the disk viscosity parameter, is important for the dust filtration process. Finally, with our updated understanding of dust filtration, we have computed Monte Carlo radiative transfer models with variable dust size distributions to generate the spectral energy distributions of disks with gaps. By comparing with transitional disk observations (e.g., GM Aur), we have found that dust filtration alone has difficulties depleting small particles sufficiently to explain the near-IR deficit of moderate M-dot transitional disks, except under some extreme circumstances. The scenario of gap opening by multiple planets studied previously suffers the same difficulty. One possible solution is to invoke both dust filtration and dust growth in the inner disk. In this scenario, a planet-induced gap filters large dust particles in the disk, and the remaining small dust particles passing to the inner disk can grow efficiently without replenishment from fragmentation of large grains. Predictions for ALMA have also been made based on all these scenarios. We conclude that dust filtration

  14. DUST FILTRATION BY PLANET-INDUCED GAP EDGES: IMPLICATIONS FOR TRANSITIONAL DISKS

    International Nuclear Information System (INIS)

    Zhu Zhaohuan; Dong Ruobing; Nelson, Richard P.; Espaillat, Catherine; Hartmann, Lee

    2012-01-01

    By carrying out two-dimensional two-fluid global simulations, we have studied the response of dust to gap formation by a single planet in the gaseous component of a protoplanetary disk—the so-called dust filtration mechanism. We have found that a gap opened by a giant planet at 20 AU in an α = 0.01, M-dot =10 -8 M ☉ yr -1 disk can effectively stop dust particles larger than 0.1 mm drifting inward, leaving a submillimeter (submm) dust cavity/hole. However, smaller particles are difficult to filter by a gap induced by a several M J planet due to (1) dust diffusion and (2) a high gas accretion velocity at the gap edge. Based on these simulations, an analytic model is derived to understand what size particles can be filtered by the planet-induced gap edge. We show that a dimensionless parameter T s /α, which is the ratio between the dimensionless dust stopping time and the disk viscosity parameter, is important for the dust filtration process. Finally, with our updated understanding of dust filtration, we have computed Monte Carlo radiative transfer models with variable dust size distributions to generate the spectral energy distributions of disks with gaps. By comparing with transitional disk observations (e.g., GM Aur), we have found that dust filtration alone has difficulties depleting small particles sufficiently to explain the near-IR deficit of moderate M-dot transitional disks, except under some extreme circumstances. The scenario of gap opening by multiple planets studied previously suffers the same difficulty. One possible solution is to invoke both dust filtration and dust growth in the inner disk. In this scenario, a planet-induced gap filters large dust particles in the disk, and the remaining small dust particles passing to the inner disk can grow efficiently without replenishment from fragmentation of large grains. Predictions for ALMA have also been made based on all these scenarios. We conclude that dust filtration with planet(s) in the disk is a

  15. Mastering JavaScript promises

    CERN Document Server

    Hussain, Muzzamil

    2015-01-01

    This book is for all the software and web engineers wanting to apply the promises paradigm to their next project and get the best outcome from it. This book also acts as a reference for the engineers who are already using promises in their projects and want to improve their current knowledge to reach the next level. To get the most benefit from this book, you should know basic programming concepts, have a familiarity with JavaScript, and a good understanding of HTML.

  16. Industrial Application of Open Pore Ceramic Foam for Molten Metal Filtration

    Science.gov (United States)

    Gauckler, L. J.; Waeber, M. M.; Conti, C.; Jacob-Dulière, M.

    Ceramic foam filters were used for industrial filtration of aluminum. Results are compared with laboratory experiments which are in good agreement with trajectory analyses of deep bed filtration for the early stage of filtration.

  17. Cross flow filtration of Oak Ridge National Laboratory liquid low-level waste

    International Nuclear Information System (INIS)

    Fowler, V.L.; Hewitt, J.D.

    1989-12-01

    A new method for disposal of Oak Ridge National Laboratory liquid low-level radioactive waste is being developed as an alternative to hydrofracture. The acceptability of the final waste form rests in part on the presence or absence of transuranic (TRU) isotopes. Inertial cross flow filtration was used in this study to determine the potential of this method for separation of the TRU isotopes from the bulk liquid stored in the Melton Valley Storage Tanks. 7 refs., 11 figs., 5 tabs

  18. Filtration characteristics of porous silicon carbide media

    International Nuclear Information System (INIS)

    Ahn, Byung Gil; Seo, Yong Chil; Yim, Sung Paal; Kim, Joon Hyung

    1991-01-01

    The characteristics of a filter such as clean filter pressure drop, filtering performance and filter drag variation with dust loading have been studied with fabricated SiC filter specimens in the laboratory and commercial ceramic filters. Several theoretical equations have been modified and applied to investigate such characteristics. To estimate the pressure drop of clean gas flow through a cylindrical porous filter, Forchheimer equation, which contains the terms of permeability and turbulent factor at a high velocity of gas, has been modified and tested with experimental data. The filtering efficiency was found to be above 99.9% and the penetration of dust decreased exponentially with dust loading. The pressure drop during filtration was measured and showed to increase exponentially with dust loading in the beginning because particles were intercepted and a cake layer was formed by structural properties of a filter. And then it increased in proportion as the cake layer thickened. The effect of dust deposition on the pressure drop could be explained theoretically using several characteristic parameters relevant to dust size, structure of filters and cake layer formation

  19. Crosslinked polytriazole membranes for organophilic filtration

    KAUST Repository

    Chisca, Stefan

    2016-12-30

    We report the preparation of crosslinked membranes for organophilic filtration, by reacting a new polytriazole with free OH groups, using non-toxic poly (ethylene glycol) diglycidyl ether (PEGDE). The OH-functionalized polymer was obtained by converting the oxadiazole to triazole rings with high yield (98%). The maximum degree of crosslinking is achieved after 6 h of reaction. The crosslinked polytriazole membranes are stable in a wide range of organic solvents and show high creep recovery, indicating the robustness of crosslinked membranes. The influence of different casting solutions and different crosslinking time on the membrane morphology and membrane performance was investigated. The membranes performance was studied in dimethylformamide (DMF) and (tetrahydrofuran) THF. We achieved a permeance for THF of 49 L m−2 h−1 bar−1 for membranes with molecular weight cut off (MWCO) of 7 kg mol−1 and a permeance for THF of 17.5 L m−2 h−1 bar−1 for membranes with MWCO of 3 kg mol−1. Our data indicate that by using the new polytriazole is possible to adjust the pore dimensions of the membranes to have a MWCO, which covers ultra- and nanofiltration range.

  20. Macular thickness after glaucoma filtration surgery.

    Science.gov (United States)

    Sesar, Antonio; Cavar, Ivan; Sesar, Anita Pusić; Geber, Mia Zorić; Sesar, Irena; Laus, Katia Novak; Vatavuk, Zoran; Mandić, Zdravko

    2013-09-01

    The aim of present study was to analyze early postoperative changes in the macular area using optical coherence tomography (OCT) after uncomplicated glaucoma filtration surgery. This prospective study included 32 patients (34 eyes) with open-angle glaucoma, which underwent trabeculectomy with or without use of mitomycin C. Exclusion criteria were macular edema, uveitis, age-related macular degeneration, blurred optical media, secondary glaucoma and angle-closure glaucoma. All standard clinical examinations were made before surgery, at the 2nd day, 1 week and 1 month after surgery. Tomography of the macula was performed during every examination using Cirrus HD OCT for the analysis of central subfield thickness. Results show that thickening of the macula was slightly higher 1 week and 1 month after operation in comparison with baseline end 2nd day postoperativelly. There was no significant difference in the change of macular thickness in patients who have used topical prostaglandins compared with those who have used other topical medications. Also, there was no difference in macular changes between patients treated with or without mitomycin C. In conclusion, we found a slight subclinical increase in macular thickness after uncomplicated trabeculectomy, for which we considered that was the result in reduction of intraocular pressure after glaucoma surgery. Macular thickening after glaucoma filtering surgery could be a physiological reaction to the stress of the retina caused by a sudden reduction of intraocular pressure and it is the consequence of altered relationship between capillary pressure and interstitial fluid pressure.

  1. CRNL research reactor retrofit Emergency Filtration System

    International Nuclear Information System (INIS)

    Philippi, H.M.

    1990-01-01

    This paper presents a brief history of NRX and NRU research reactor effluent air treatment systems before describing the selection and design of an appropriate retrofit Emergency Filtration System (EFS) to serve these reactors and the future MX-10 isotope production reactor. The conceptual design of the EFS began in 1984. A standby concrete shielding filter-adsorber system, sized to serve the reactor with the largest exhaust flow, was selected. The standby system, bypassed under normal operating conditions, is equipped with normal exhaust stream shutoff and diversion valves to be activated manually when an emergency is anticipated, or automatically when emergency levels of gamma radiation are detected in the exhaust stream. The first phase of the EFS installation, that is the construction of the EFS and the connection of NRU to the system, was completed in 1987. The second phase of construction, which includes the connection of NRX and provisions for the future connection of MX-10, is to be completed in 1990

  2. Filtration of submicrometer particles by pelagic tunicates.

    Science.gov (United States)

    Sutherland, Kelly R; Madin, Laurence P; Stocker, Roman

    2010-08-24

    Salps are common in oceanic waters and have higher per-individual filtration rates than any other zooplankton filter feeder. Although salps are centimeters in length, feeding via particle capture occurs on a fine, mucous mesh (fiber diameter d approximately 0.1 microm) at low velocity (U = 1.6 +/- 0.6 cmxs(-1), mean +/- SD) and is thus a low Reynolds-number (Re approximately 10(-3)) process. In contrast to the current view that particle encounter is dictated by simple sieving of particles larger than the mesh spacing, a low-Re mathematical model of encounter rates by the salp feeding apparatus for realistic oceanic particle-size distributions shows that submicron particles, due to their higher abundances, are encountered at higher rates (particles per time) than larger particles. Data from feeding experiments with 0.5-, 1-, and 3-microm diameter polystyrene spheres corroborate these findings. Although particles larger than 1 microm (e.g., flagellates, small diatoms) represent a larger carbon pool, smaller particles in the 0.1- to 1-microm range (e.g., bacteria, Prochlorococcus) may be more quickly digestible because they present more surface area, and we find that particles smaller than the mesh size (1.4 microm) can fully satisfy salp energetic needs. Furthermore, by packaging submicrometer particles into rapidly sinking fecal pellets, pelagic tunicates can substantially change particle-size spectra and increase downward fluxes in the ocean.

  3. Crosslinked polytriazole membranes for organophilic filtration

    KAUST Repository

    Chisca, Stefan; Falca, Gheorghe; Musteata, Valentina-Elena; Boi, Cristiana; Nunes, Suzana Pereira

    2016-01-01

    We report the preparation of crosslinked membranes for organophilic filtration, by reacting a new polytriazole with free OH groups, using non-toxic poly (ethylene glycol) diglycidyl ether (PEGDE). The OH-functionalized polymer was obtained by converting the oxadiazole to triazole rings with high yield (98%). The maximum degree of crosslinking is achieved after 6 h of reaction. The crosslinked polytriazole membranes are stable in a wide range of organic solvents and show high creep recovery, indicating the robustness of crosslinked membranes. The influence of different casting solutions and different crosslinking time on the membrane morphology and membrane performance was investigated. The membranes performance was studied in dimethylformamide (DMF) and (tetrahydrofuran) THF. We achieved a permeance for THF of 49 L m−2 h−1 bar−1 for membranes with molecular weight cut off (MWCO) of 7 kg mol−1 and a permeance for THF of 17.5 L m−2 h−1 bar−1 for membranes with MWCO of 3 kg mol−1. Our data indicate that by using the new polytriazole is possible to adjust the pore dimensions of the membranes to have a MWCO, which covers ultra- and nanofiltration range.

  4. Efficient filtration system for paraffin-catalyst slurry separation

    Directory of Open Access Journals (Sweden)

    Khodagholi Mohammad Ali

    2013-01-01

    Full Text Available The filtration efficiency for separating liquid paraffin (or water from a slurry consisting of 25 weight% spherical alumina in a Slurry Bubble Column Reactor (SBCR comprised of a cylindrical tube of 10 cm diameter and 150 cm length was studied. Various differential pressures (ΔP were applied to two separate tubular sintered metal stainless steel filter elements with nominal pore size of 4 and 16μm. The experimental results disclosed that the rate of filtrations increased on applying higher differential pressure to the filter element. Albeit this phenomenon is limited to moderate ΔPs and for ΔP more than 1 bar is neither harmful nor helpful. The highest filtration rates at ΔPs higher than 1 bar were 170 and 248 ml/minute for 4 and 16μm respectively. Using water as the liquid in slurry the rate of filtration enhanced to 4 folds, and this issue reveals impact of viscosity on filtration efficiency clearly. In all situations, the total amount of particles present in the filtrate part never exceeded a few parts per million (ppm. The statistical analysis of the SEM image of the filtrate indicated that by applying higher pressure difference to the filter element the frequency percent of larger particle size increases. The operation of filter cake removing was performed with back flashing of 300 ml of clean liquid with pressures of 3-5 bar of N2 gas.

  5. SPECTRAL FILTRATION OF IMAGES BY MEANS OF DISPERSIVE SYSTEMS

    Directory of Open Access Journals (Sweden)

    I. M. Gulis

    2016-01-01

    Full Text Available Instruments for spectral filtration of images are an important element of the systems used in remote sensing, medical diagnostics, in-process measurements. The aim of this study is analysis of the functional features and characteristics of the proposed two image monochromator versions which are based on dispersive spectral filtering. The first is based on the use of a dispersive monochromator, where collimating and camera lenses form a telescopic system, the dispersive element of which is within the intermediate image plane. The second version is based on an imaging double monochromator with dispersion subtraction by back propagation. For the telescopic system version, the spectral and spatial resolutions are estimated, the latter being limited by aberrations and diffraction from the entrance slit. The device has been numerically simulated and prototyped. It is shown that for the spectral bandwidth 10 nm (visible spectral range, the aberration-limited spot size is from 10–20 μm at the image center to about 30 μm at the image periphery for the image size 23–27 mm. The monochromator with dispersion subtraction enables one to vary the spectral resolution (up to 1 nm and higher by changing the intermediate slit width. But the distinctive feature is a significant change in the selected central wavelength over the image field. The considered designs of dispersive image monochromators look very promising due to the particular advantages over the systems based on tunable filters as regards the spectral resolution, fast tuning, and the spectral contrast. The monochromator based on a telescopic system has a simple design and a rather large image field but it also has a limited light throughput due to small aperture size. The monochromator with dispersion subtraction has higher light throughput, can provide high spectral resolution when recording a full data cube in a series of measuring acts for different dispersive element positions. 

  6. Additive Difference Schemes for Filtration Problems in Multilayer Systems

    CERN Document Server

    Ayrjan, E A; Pavlush, M; Fedorov, A V

    2000-01-01

    In the present paper difference schemes for solution of the plane filtration problem in multilayer systems are analyzed within the framework of difference schemes general theory. Attention is paid to splitting the schemes on physical processes of filtration along water-carring layers and vertical motion between layers. Some absolutely stable additive difference schemes are obtained the realization of which needs no software modification. Parallel algorithm connected with the solving of the filtration problem in every water-carring layer on a single processor is constructed. Program realization on the multi-processor system SPP2000 at JINR is discussed.

  7. Colour based fire detection method with temporal intensity variation filtration

    Science.gov (United States)

    Trambitckii, K.; Anding, K.; Musalimov, V.; Linß, G.

    2015-02-01

    Development of video, computing technologies and computer vision gives a possibility of automatic fire detection on video information. Under that project different algorithms was implemented to find more efficient way of fire detection. In that article colour based fire detection algorithm is described. But it is not enough to use only colour information to detect fire properly. The main reason of this is that in the shooting conditions may be a lot of things having colour similar to fire. A temporary intensity variation of pixels is used to separate them from the fire. These variations are averaged over the series of several frames. This algorithm shows robust work and was realised as a computer program by using of the OpenCV library.

  8. Colour based fire detection method with temporal intensity variation filtration

    International Nuclear Information System (INIS)

    Trambitckii, K; Musalimov, V; Anding, K; Linß, G

    2015-01-01

    Development of video, computing technologies and computer vision gives a possibility of automatic fire detection on video information. Under that project different algorithms was implemented to find more efficient way of fire detection. In that article colour based fire detection algorithm is described. But it is not enough to use only colour information to detect fire properly. The main reason of this is that in the shooting conditions may be a lot of things having colour similar to fire. A temporary intensity variation of pixels is used to separate them from the fire. These variations are averaged over the series of several frames. This algorithm shows robust work and was realised as a computer program by using of the OpenCV library

  9. Evaluation of filtration and distillation methods for recycling automotive coolant

    International Nuclear Information System (INIS)

    Randall, P.M.; Gavaskar, A.R.

    1992-01-01

    Government regulations and high waste disposal cost of spent automotive coolant have driven the vehicle maintenance industry to explore on-site recycling. The USEPA in cooperation with the New Jersey Department of Environmental Protection (NJDEP) and the New Jersey Department of Transportation (NJDOT) evaluated two commercially available technologies that have potential for reducing the volume of spent automotive coolant. The objective of this study was to evaluate the quality of the recycled coolant, the pollution prevention potential, and the economic feasibility of the technologies

  10. Nuclear energy: obstacles and promises

    International Nuclear Information System (INIS)

    Bacher, P.

    2003-01-01

    Nuclear energy has distinctive merits (sustainable resources, low costs, no greenhouse gases) but its development must overcome serious hurdles (fear of accidents, radio-phobia, waste management). The large unit size of present-day reactors is compatible only with large electrical grids, and involves a high capital cost. Taking into account these different factors, the paper outlines how nuclear energy may contribute to the reduction of greenhouse gases, and which are the most promising developments. (author)

  11. The promise of cyborg intelligence.

    Science.gov (United States)

    Brown, Michael F; Brown, Alexander A

    2017-03-01

    Yu et al. (2016) demonstrated that algorithms designed to find efficient routes in standard mazes can be integrated with the natural processes controlling rat navigation and spatial choices, and they pointed out the promise of such "cyborg intelligence" for biorobotic applications. Here, we briefly describe Yu et al.'s work, explore its relevance to the study of comparative cognition, and indicate how work involving cyborg intelligence would benefit from interdisciplinary collaboration between behavioral scientists and engineers.

  12. Freedom: A Promise of Possibility.

    Science.gov (United States)

    Bunkers, Sandra Schmidt

    2015-10-01

    The idea of freedom as a promise of possibility is explored in this column. The core concepts from a research study on considering tomorrow (Bunkers, 1998) coupled with humanbecoming community change processes (Parse, 2003) are used to illuminate this notion. The importance of intentionality in human freedom is discussed from both a human science and a natural science perspective. © The Author(s) 2015.

  13. Flux Enhancement in Crossflow Membrane Filtration: Fouling and It's Minimization by Flow Reversal. Final Report

    International Nuclear Information System (INIS)

    Shamsuddin Ilias

    2005-01-01

    Fouling problems are perhaps the single most important reason for relatively slow acceptance of ultrafiltration in many areas of chemical and biological processing. To overcome the losses in permeate flux associated with concentration polarization and fouling in cross flow membrane filtration, we investigated the concept of flow reversal as a method to enhance membrane flux in ultrafiltration. Conceptually, flow reversal prevents the formation of stable hydrodynamic and concentration boundary layers at or near the membrane surface. Further more, periodic reversal of the flow direction of the feed stream at the membrane surface results in prevention and mitigation of membrane fouling. Consequently, these advantages are expected to enhance membrane flux significantly. A crossflow membrane filtration unit was designed and built to test the concept of periodic flow reversal for flux enhancement. The essential elements of the system include a crossflow hollow fiber membrane module integrated with a two-way valve to direct the feed flow directions. The two-way valve is controlled by a controller-timer for periodic reversal of flow of feed stream. Another important feature of the system is that with changing feed flow direction, the permeate flow direction is also changed to maintain countercurrent feed and permeate flows for enhanced mass transfer driving force (concentration difference). Three feed solutions (Bovine serum albumin (BSA), apple juice and citrus fruit pectin) were studied in crossflow membrane filtration. These solutes are well-known in membrane filtration for their fouling and concentration polarization potentials. Laboratory-scale tests on a hollow-fiber ultrafiltration membrane module using each of the feed solutes show that under flow reversal conditions, the permeate flux is significantly enhanced when compared with the conventional unidirectional flow. The flux enhancement is dramatic (by an order of magnitude) with increased feed concentration and

  14. Daya Antibakteri Filtrat Asam Laktat dan Bakteriosin Lactobacillus bulgaricus KS1 dalam Menghambat Pertumbuhan Klebsiella pneumoniae Strain ATCC 700603, CT1538, dan S941

    Directory of Open Access Journals (Sweden)

    Prima Nanda Fauziah

    2015-03-01

    Full Text Available Lactobacillus bulgaricus produces lactic acid and bacteriocin which have been reported to have various pharmacologic properties, including their role an antibacterial agent. Klebsiella pneumoniae, as an agent of pneumonia, remains a public health problem in tropical countries. This study was aimed to observe the antibacterial activities of lactic acid filtrate and bacteriocins of L. bulgaricus toward againsts K. pneumoniae strains by in vitro experiment. The experiment took place in Microbiology Laboratory, Teaching Hospital, Padjadjaran University, Bandung, August–October 2012. In vitro laboratory analytic study has been conducted on lactic acid filtrate and bacteriocins of L. bulgaricus against the K. pneumoniae strains. The study used agar pour plate and agar disk diffusion method and analyzed by ANAVA followed by Duncan’s multiple range test (DMRT. The 30% lactic acid filtrate and 20% bacteriocins filtrate concentrations of L. bulgaricus showed bactericidal characteristics againts the growth of K. pneumoniae strains. Greater concentration of lactic acid filtrate and bacteriocins of L. bulgaricus led toincreasing effect of growth inhibition zones of K. pneumoniae strains. Statistical analysis of variance (ANOVA showed that the greatest concentration effect of L. bulgaricus filtratefor inhibiting K. pneumoniae strains was achieved in 90% lactic acid filtrate concentration treatment, whereas the greatest inhibition zones for K. pneumoniae ATCC 700603 was obtaubed in 90% bacteriocins filtrate concentration, amounting 16.667 mm. In conclusion, lactic acid filtrate and bacteriocins L. bulgaricus have antibacterial effects on K. pneumoniae. The level of antibacterial effect of L. bulgaricus against the growth of K. pneumoniae strains depends on the type of filtrate, L. bulgaricus filtrate concentration, and K. pneumoniae strain.

  15. Water quality and treatment of river bank filtrate

    NARCIS (Netherlands)

    De Vet, W.W.J.M.; Van Genuchten, C.C.A.; Van Loosdrecht, M.C.M.; Van Dijk, J.C.

    2010-01-01

    In drinking water production, river bank filtration has the advantages of dampening peak concentrations of many dissolved components, substantially removing many micropollutants and removing, virtually completely, the pathogens and suspended solids. The production aquifer is not only fed by the

  16. Water quality and treatment of river bank filtrate

    NARCIS (Netherlands)

    De Vet, W.W.J.M.; Van Genuchten, C.C.A.; Van Loosdrecht, M.C.M.; Van Dijk, J.C.

    2009-01-01

    In drinking water production, river bank filtration has the advantages of dampening peak concentrations of many dissolved components, substantially removing many micropollutants and removing, virtually completely, the pathogens and suspended solids. The production aquifer is not only fed by the

  17. Scaling and particulate fouling in membrane filtration systems

    NARCIS (Netherlands)

    Boerlage, S.F.E.

    2001-01-01

    Membrane filtration technologies have emerged as cost competitive and viable techniques in drinking and industrial water production. Despite advancements in membrane manufacturing and technology, membrane scaling and fouling remain major problems and may limit future growth in the industry. Scaling

  18. Initial testing of electrospun nanofibre filters in water filtration ...

    African Journals Online (AJOL)

    2009-11-17

    Nov 17, 2009 ... for water filtration applications, but that further improvements are necessary before these membranes can be ... power supply, and a grounded collector. .... nanofibres so that the pore size increases and bacteria leak through ...

  19. Thermo-resistant filtration fabrics for hot gas extraction

    International Nuclear Information System (INIS)

    Wierzbowska, T.

    1992-01-01

    Types and technical and utilizing data of heat resistant filtrating fabrics initiated to production by 'Moratex' and provided for dust extraction of technical gas from various industrial processes have been discussed. (author). 8 refs, 2 tabs

  20. Water Clarity Simulant for K East Basin Filtration Testing

    Energy Technology Data Exchange (ETDEWEB)

    Schmidt, Andrew J.

    2006-01-20

    This document provides a simulant formulation intended to mimic the behavior of the suspended solids in the K East (KE) Basin fuel storage pool. The simulant will be used to evaluate alternative filtration apparatus to improve Basin water clarity and to possibly replace the existing sandfilter. The simulant was formulated based on the simulant objectives, the key identified parameters important to filtration, the composition and character of the KE Basin suspended sludge particles, and consideration of properties of surrogate materials.

  1. Development of filtration equipment to reuse PFC decontamination wastewater

    International Nuclear Information System (INIS)

    Kim, Gye Nam; Lee, Sung Yeol; Won, Hui Jun; Jung Chong Hun; Oh, Won Zin; Park, Jin Ho

    2005-01-01

    When PFC(Perfluorocarbonate) decontamination technology is applied to removal of radioactive contaminated particulate adhered at surface during the operation of nuclear research facilities, it is necessary to develop a filtration equipment to reuse of PFC solution due to high price, also to minimize the volume of second wastewater. Contaminated characteristics of hot particulate was investigated and a filtration process was presented to remove suspended radioactive particulate from PFC decontamination wastewater generated on PFC decontamination

  2. Development of electromagnetic filtration in the feed water circuits

    International Nuclear Information System (INIS)

    Dolle, L.

    1980-01-01

    Electromagnetic filtration in the feed water circuit of the steam generators in nuclear power plants is efficient towards insoluble corrosion products. The principle of electromagnetic filtration is shortly recalled and the results of corresponding development work are summarized. The magnitude of water volumes to be treated on the two priviledged parts of the circuit are estimated. These parts are on the feed water tank level and on the blow-down of the steam generator. The practical applications are discussed [fr

  3. Apparatus for Crossflow Filtration Testing of High Level Waste Samples

    International Nuclear Information System (INIS)

    Nash, C.

    1998-05-01

    Remotely-operated experimental apparatuses for verifying crossflow filtration of high level nuclear waste have been constructed at the Savannah River Site (SRS). These units have been used to demonstrate filtration processes at the Savannah River Site, Oak Ridge National Laboratory, the Idaho National Engineering and Environmental Laboratory, and Pacific Northwest National Laboratory. The current work covers the design considerations for experimentation as well as providing results from testing at SRS

  4. [Why? How? What for? We must measure the glomerular filtration].

    Science.gov (United States)

    Treviño-Becerra, Alejandro

    2010-01-01

    The measurement of the glomerular filtration shows the degree of the functional qualities and the proficiency of the renal system. Despite new technologies, at present the best accepted technique for measuring the glomerular filtration in most countries is the clearance of creatinine in 24 hour urine. The clearance of creatinine has the advantage that it is confident, easy to reproduce, without technical limitations and low cost.

  5. Estimated Glomerular Filtration Rate; Laboratory Implementation and Current Global Status.

    Science.gov (United States)

    Miller, W Greg; Jones, Graham R D

    2018-01-01

    In 2002, the Kidney Disease Outcomes Quality Initiative guidelines for identifying and treating CKD recommended that clinical laboratories report estimated glomerular filtration rate (eGFR) with every creatinine result to assist clinical practitioners to identify people with early-stage CKD. At that time, the original Modification of Diet in Renal Disease (MDRD) Study equation based on serum creatinine measurements was recommended for calculating eGFR. Because the MDRD Study equation was developed using a nonstandardized creatinine method, a Laboratory Working Group of the National Kidney Disease Education program was formed and implemented standardized calibration traceability for all creatinine methods from global manufacturers by approximately 2010. A modified MDRD Study equation for use with standardized creatinine was developed. The Chronic Kidney Disease Epidemiology Collaboration developed a new equation in 2009 that was more accurate than the MDRD Study equation at values above 60 mL/min/1.73 m 2 . As of 2017, reporting eGFR with creatinine is almost universal in many countries. A reference system for cystatin C became available in 2010, and manufacturers are in the process to standardize cystatin C assays. Equations for eGFR based on standardized cystatin C alone and with creatinine are now available from the Chronic Kidney Disease Epidemiology Collaboration and other groups. Copyright © 2017 National Kidney Foundation, Inc. Published by Elsevier Inc. All rights reserved.

  6. Measurement of renal glomerular filtration rate using labelled substances with compartmental analysis

    International Nuclear Information System (INIS)

    Eberstadt, P.L.

    1981-10-01

    Using a model for the two-compartmental open system and experiments on animals (rabbits and dogs) as well as on human healthy volunteers, an attempt was made to study the advantages and limitations of different radionuclide methods for glomerular filtration rate determination. Labelled compounds used in different combinations were: 3 H-inulin, sup(113m)In-EDTA, 131 I-iothalamate, sup(99m)Tc-DTPA and 14 C-creatinine. The results of the study lead to some working hypotheses concerning the value of creatinine and other labelled substances in the measurement of glomerular filtration rate in clinical practice. The advantages and disadvantages of individual methods summarized in the final report are generally in agreement with the present views of many research workers. Also the hypothesis can be justified that the different labelled compounds which have been studied might be handled independently by the membranes involved but at the long run produce similar homeostatic balance

  7. A Combined Approach to Measure Micropollutant Behaviour during Riverbank Filtration

    Science.gov (United States)

    van Driezum, Inge; Saracevic, Ernis; Derx, Julia; Kirschner, Alexander; Sommer, Regina; Farnleitner, Andreas; Blaschke, Alfred Paul

    2016-04-01

    Riverbank filtration (RBF) systems are widely used as natural treatment process. The advantages of RBF over surface water abstraction are the elimination of for example suspended solids, biodegradable compounds (like specific micropollutants), bacteria and viruses (Hiscock and Grischek, 2002). However, in contrast to its importance, remarkably less is known on the respective external (e.g. industrial or municipal sewage) and the internal (e.g. wildlife and agricultural influence) sources of contaminants, the environmental availability and fate of the various hazardous substances, and its potential transport during soil and aquifer passage. The goal of this study is to get an insight in the behaviour of various micropollutants and microbial indicators during riverbank filtration. Field measurements were combined with numerical modelling approaches. The study area comprises an alluvial backwater and floodplain area downstream of Vienna. The river is highly dynamic, with discharges ranging from 900 m3/s during low flow to 11000 m3/s during flood events. Samples were taken in several monitoring wells along a transect extending from the river towards a backwater river in the floodplain. Three of the piezometers were situated in the first 20 meters away from the river in order to obtain information about micropollutant behaviour close to the river. A total of 9 different micropollutants were analysed in grab samples taken under different river flow conditions (n=33). Following enrichment using SPE, analysis was performed using high performance liquid chromatography-tandem mass spectrometry. Faecal indicators (E. coli and enterococci) and bacterial spores were enumerated in sample volumes of 1 L each using cultivation based methods (ISO 16649-1, ISO 7899-2:2000 and ISO 6222). The analysis showed that some compounds, e.g. ibuprofen and diclofenac, were only found in the river. These compounds were already degraded in the first ten meters away from the river. Analysis of

  8. Hanford underground storage tank waste filtration process evaluation

    International Nuclear Information System (INIS)

    Walker, B.W.; McCabe, D.J.

    1997-01-01

    The purpose of this filter study was to evaluate cross-flow filtration as effective solid-liquid separation technology for treating Hanford wastes, outline operating conditions for equipment, examine the expected filter flow rates, and determine proper cleaning. Two Hanford waste processing applications have been identified as candidates for the use of cross-flow filtration. The first of the Hanford applications involves filtration of the decanted supernate from sludge leaching and washing operations. This process involves the concentration and removal of dilute (0.05 wt percent) fines from the bulk of the supernate. The second application involves filtration to wash and concentrate the sludge during out-of-tank processing. This process employs a relatively concentrated (8 wt percent) solids feed stream. Filter studies were conducted with simulants to evaluate whether 0.5 micron cross-flow sintered metal Mott filters and 0.1 micron cross-flow Graver filters can perform solid-liquid separation of the solid/liquid waste streams effectively. In cross-flow filtration the fluid to be filtered flows in parallel to the membrane surface and generates shearing forces and/or turbulence across the filter medium. This shearing influences formation of filter cake stabilizing the filtrate flow rate

  9. Wind Turbine Gearbox Oil Filtration and Condition Monitoring

    Energy Technology Data Exchange (ETDEWEB)

    Sheng, Shuangwen

    2015-10-25

    This is an invited presentation for a pre-conference workshop, titled advances and opportunities in lubrication: wind turbine, at the 2015 Society of Tribologists and Lubrication Engineers (STLE) Tribology Frontiers Conference held in Denver, CO. It gives a brief overview of wind turbine gearbox oil filtration and condition monitoring by highlighting typical industry practices and challenges. The presentation starts with an introduction by covering recent growth of global wind industry, reliability challenges, benefits of oil filtration and condition monitoring, and financial incentives to conduct wind operation and maintenance research, which includes gearbox oil filtration and condition monitoring work presented herein. Then, the presentation moves on to oil filtration by stressing the benefits of filtration, discussing typical main- and offline-loop practices, highlighting important factors considered when specifying a filtration system, and illustrating real-world application challenges through a cold-start example. In the next section on oil condition monitoring, a discussion on oil sample analysis, oil debris monitoring, oil cleanliness measurements and filter analysis is given based on testing results mostly obtained by and at NREL, and by pointing out a few challenges with oil sample analysis. The presentation concludes with a brief touch on future research and development (R and D) opportunities. It is hoping that the information presented can inform the STLE community to start or redirect their R and D work to help the wind industry advance.

  10. The impact of available anti-glaucoma therapy on the volume and age profile of patients undergoing glaucoma filtration surgery.

    LENUS (Irish Health Repository)

    Keane, P A

    2012-02-01

    PURPOSE: To investigate whether new classes of glaucoma medication have influenced glaucoma filtration surgery over a 20-year period in the southeast region of Ireland. METHODS: All patients undergoing glaucoma filtration surgery between January 1986 and December 2005 in Waterford Regional Hospital were identified. The following data were recorded for each patient: age; sex; and type of filtration procedure. RESULTS: Over the 20-year study period two consultant ophthalmic surgeons performed a total of 760 glaucoma filtration procedures on patients aged over 20 years. The annual average number of glaucoma surgeries declined steadily, defined by availability of different topical anti-glaucoma medications, from an average of 23.75 surgeries per surgeon per year in the subperiod 1986-1995, to 21 in 1996, 20 in 1997, and 12.69 surgeries per surgeon per year in 1998-2005, these differences being statistically significant (general linear model, P<0.001). The age profile of patients did not change significantly over the course of the study period. CONCLUSIONS: The volume of patients requiring glaucoma filtration surgery under the care of two consultant ophthalmic surgeons decreased over the 20-year study period, an era in which three classes of anti-glaucoma medications were made available. However, an increase in the age profile of patients undergoing glaucoma filtration surgery during the same period was not observed. Further study is required to resolve whether introduction of the new topical anti-glaucoma medications has led to a real reduction in the demand for glaucoma filtration surgery, or has just led to the deferral of such a demand.

  11. MATHEMATICAL MODELING OF UNSTEADY FILTRATION OF ELASTIC LIQUID IN AN INHOMOGENEOUS RESERVOIR

    Directory of Open Access Journals (Sweden)

    A. G. Balamirzoev

    2013-01-01

    Full Text Available The article considers the possibility of numerical solution of two-dimensional problem of unsteady filtration in an inhomogeneous elastic liquid reservoir. The problem of finding the distribution of the pressure p(x,y,t in the process of exploitation of deposits is reduced to the solution of a differential equation of parabolic type with variable coefficients. The problem is solved approximately by using the method of finite differences.

  12. Chitin fulfilling a biomaterials promise

    CERN Document Server

    Khor, Eugene

    2001-01-01

    The second edition of Chitin underscores the important factors for standardizing chitin processing and characterization. It captures the essential interplay between chitin's assets and limitations as a biomaterial, placing the past promises of chitin in perspective, addressing its present realities and offering insight into what is required to realize chitin's destiny (including its derivative, chitosan) as a biomaterial of the twenty-first century. This book is an ideal guide for both industrialists and researchers with a vested interest in commercializing chitin.An upd

  13. Delivery of antifibroblast agents as adjuncts to filtration surgery. Part I--Periocular clearance of cobalt-57 bleomycin in experimental drug delivery: pilot study in the rabbit

    Energy Technology Data Exchange (ETDEWEB)

    Kay, J.S.; Litin, B.S.; Woolfenden, J.M.; Chvapil, M.; Herschler, J.

    1986-10-01

    Antitumor and antifibroblast agents show promise as adjuncts after glaucoma filtration surgery in reducing postoperative scarring and failure. We used nuclear imaging in rabbits to investigate periocular clearance of one such agent (/sup 57/Co-bleomycin). Sub-Tenon injection was compared to other delivery techniques. Our results showed that a collagen sponge and a silastic disc implant with a microhole prolonged drug delivery when compared to sub-Tenon injection alone or injection with a viscosity enhancing agent (0.5% sodium hyaluronate). We theorize that if an antifibroblast agent can be delivered in small and sustained amounts after filtration surgery, this may prolong bleb longevity and avoid unnecessary drug toxicity.

  14. Delivery of antifibroblast agents as adjuncts to filtration surgery. Part I--Periocular clearance of cobalt-57 bleomycin in experimental drug delivery: pilot study in the rabbit

    International Nuclear Information System (INIS)

    Kay, J.S.; Litin, B.S.; Woolfenden, J.M.; Chvapil, M.; Herschler, J.

    1986-01-01

    Antitumor and antifibroblast agents show promise as adjuncts after glaucoma filtration surgery in reducing postoperative scarring and failure. We used nuclear imaging in rabbits to investigate periocular clearance of one such agent ( 57 Co-bleomycin). Sub-Tenon injection was compared to other delivery techniques. Our results showed that a collagen sponge and a silastic disc implant with a microhole prolonged drug delivery when compared to sub-Tenon injection alone or injection with a viscosity enhancing agent (0.5% sodium hyaluronate). We theorize that if an antifibroblast agent can be delivered in small and sustained amounts after filtration surgery, this may prolong bleb longevity and avoid unnecessary drug toxicity

  15. Prediction of the filtrate particle size distribution from the pore size distribution in membrane filtration: Numerical correlations from computer simulations

    Science.gov (United States)

    Marrufo-Hernández, Norma Alejandra; Hernández-Guerrero, Maribel; Nápoles-Duarte, José Manuel; Palomares-Báez, Juan Pedro; Chávez-Rojo, Marco Antonio

    2018-03-01

    We present a computational model that describes the diffusion of a hard spheres colloidal fluid through a membrane. The membrane matrix is modeled as a series of flat parallel planes with circular pores of different sizes and random spatial distribution. This model was employed to determine how the size distribution of the colloidal filtrate depends on the size distributions of both, the particles in the feed and the pores of the membrane, as well as to describe the filtration kinetics. A Brownian dynamics simulation study considering normal distributions was developed in order to determine empirical correlations between the parameters that characterize these distributions. The model can also be extended to other distributions such as log-normal. This study could, therefore, facilitate the selection of membranes for industrial or scientific filtration processes once the size distribution of the feed is known and the expected characteristics in the filtrate have been defined.

  16. Combination of granular activated carbon adsorption and deep-bed filtration as a single advanced wastewater treatment step for organic micropollutant and phosphorus removal.

    Science.gov (United States)

    Altmann, Johannes; Rehfeld, Daniel; Träder, Kai; Sperlich, Alexander; Jekel, Martin

    2016-04-01

    process alternative. Both options yielded comparable OMP removals for most compounds at similar carbon usage rates, but GAC achieved considerably higher removals for biodegradable OMPs. Based on the results, the application of GAC in combination with coagulation/filtration represents a promising alternative to powdered activated carbon and ozone for advanced wastewater treatment. Copyright © 2016 Elsevier Ltd. All rights reserved.

  17. Integrated bio-oxidation and adsorptive filtration reactor for removal of arsenic from wastewater.

    Science.gov (United States)

    Kamde, Kalyani; Dahake, Rashmi; Pandey, R A; Bansiwal, Amit

    2018-01-08

    Recently, removal of arsenic from different industrial effluent discharged using simple, efficient and low-cost technique has been widely considered. In this study, removal of arsenic (As) from real wastewater has been studied employing modified bio-oxidation followed by adsorptive filtration method in a novel continuous flow through the reactor. This method includes biological oxidation of ferrous to ferric ions by immobilized Acidothiobacillus ferrooxidans bacteria on granulated activated carbon (GAC) in fixed bed bio-column reactor with the adsorptive filtration unit. Removal efficiency was optimized regarding the initial flow rate of media and ferrous ions concentration. Synthetic wastewater sample having different heavy metal ions such as Arsenic (As), Cobalt (Co), Chromium (Cr), Copper (Cu), Iron (Fe), Lead (Pb) and Manganese (Mn) were also used in the study. The structural and surface changes occurring after the treatment process were scrutinized using FT-IR and Scanning Electron Microscopy (SEM) analysis. The finding showed that not only arsenic can be removed considerably in the bioreactor system, but also removing efficiency was much more (oxidation with adsorptive filtration method improves the removal efficiency of arsenic and other heavy metal ions in wastewater sample.

  18. Mitigation of radon and thoron decay products by filtration

    International Nuclear Information System (INIS)

    Wang Jin; Meisenberg, Oliver; Chen Yongheng; Karg, Erwin; Tschiersch, Jochen

    2011-01-01

    Inhalation of indoor radon ( 222 Rn) and thoron ( 220 Rn) decay products is the most important source of exposure to ionizing radiation for the human respiratory tract. Decreasing ventilation rates due to energy saving reasons in new buildings suggest additional active mitigation techniques to reduce the exposure in homes with high radon and thoron concentrations but poor ventilation. Filtration techniques with HEPA filters and simple surgical mask material have been tested for their potential to reduce the indoor exposure in terms of the total effective dose for mixed radon and thoron indoor atmospheres. The tests were performed inside an experimental room providing stable conditions. Filtration (at filtration rates of 0.2 h -1 and larger) removes attached radon and thoron decay products effectively but indoor aerosol as well. Therefore the concentration of unattached decay products (which have a higher dose coefficient) may increase. The decrease of the attached decay product concentrations could be theoretically described by a slowly decreasing exponential process. For attached radon decay products, it exhibited a faster but weaker removal process compared to attached thoron decay products (- 70% for attached radon decay products and - 80% for attached thoron decay products at a filtration rate of 0.5 h -1 with an HEPA filter). The concentration of unattached thoron decay products increased distinctly during the filtration process (+ 300%) while that of unattached radon decay products rose only slightly though at a much higher level (+ 17%). In the theoretical description these observed differences could be attributed to the different half-lives of the nuclides. Considering both effects, reduced attached and increased unattached decay product concentrations, filtration could significantly decrease the total effective dose from thoron whereas the overall effect on radon dose is small. A permanent filtration is recommended because of the slow decrease of the

  19. Four years experience with filtration systems in commercial nurseries for eliminating Phytophthora species from recirculation water

    Science.gov (United States)

    T. Ufer; M. Posner; H.-P. Wessels; S. Wagner; K. Kaminski; T. Brand; Werres S.

    2008-01-01

    In a four year project, three different filtration systems were tested under commercial nursery conditions to eliminate Phytophthora spp. from irrigation water. Five nurseries were involved in the project. Slow sand filtration systems were tested in three nurseries. In the fourth nursery, a filtration system with lava grains (Shieer® Bio filtration)...

  20. Research on Hydrophilic Nature of Polyvinylpyrrolidone on Polysulfone Membrane Filtration

    Science.gov (United States)

    Tiron, L. G.; Vlad, M.; Baltă, Ş.

    2018-06-01

    The membranes used in wastewater filtration are obtained from polymers, this technique is widely applied because of the small installations and low costs as against conventional systems. The polymeric membranes have high mechanical strength and flexibility, but is a challenge to improve in the same time the permeability and retention capacity of the membranes. A process that can improve the membrane properties is the addition of additives to the polymer solution, resulting in noticeable changes in the resulting membrane structure. Polyvinylpyrrolidone (PVP) is a highly hydrophilic polymer, used as a food additive that acts as stabilizer and thickening agent, which brings improvements in membrane properties. This study analyses the effect of polyvinylpyrrolidone (PVP) on the casting solution of the prepared membranes. The polymer solution was prepared from polysulfone (PSf) and N-methyl-2-pyrrolidone (NMP) at different concentrations. The membranes were obtained by phase inversion method. The PSf/PVP/NMP membranes with different concentrations were characterized by contact angle measurements, surface roughness, morphological structure and permeation tests. The results show that the hydrophilic nature of PVP improve the pure water flux, the contact angle and exhibit a higher anti-fouling property.

  1. Standard filtration practices may significantly distort planktonic microbial diversity estimates

    Directory of Open Access Journals (Sweden)

    Cory Cruz Padilla

    2015-06-01

    Full Text Available Fractionation of biomass by filtration is a standard method for sampling planktonic microbes. It is unclear how the taxonomic composition of filtered biomass changes depending on sample volume. Using seawater from a marine oxygen minimum zone, we quantified the 16S rRNA gene composition of biomass on a prefilter (1.6 μm pore-size and a downstream 0.2 μm filter over sample volumes from 0.05 to 5 L. Significant community shifts occurred in both filter fractions, and were most dramatic in the prefilter community. Sequences matching Vibrionales decreased from ~40-60% of prefilter datasets at low volumes (0.05-0.5 L to less than 5% at higher volumes, while groups such at the Chromatiales and Thiohalorhabdales followed opposite trends, increasing from minor representation to become the dominant taxa at higher volumes. Groups often associated with marine particles, including members of the Deltaproteobacteria, Planctomycetes and Bacteroidetes, were among those showing the greatest increase with volume (4 to 27-fold. Taxon richness (97% similarity clusters also varied significantly with volume, and in opposing directions depending on filter fraction, highlighting potential biases in community complexity estimates. These data raise concerns for studies using filter fractionation for quantitative comparisons of aquatic microbial diversity, for example between free-living and particle-associated communities.

  2. Purification of Peptide Components including Melittin from Bee Venom using gel filtration chromatography and propionic acid/urea polyacrylamide gel electrophoresis

    Directory of Open Access Journals (Sweden)

    Young Chon Choi

    2006-06-01

    Full Text Available Objectives : This study was conducted to carry out Purification of Melittin and other peptide components from Bee Venom using gel filtration chromatography and propionic acid/urea polyacrylamide gel electrophoresis Methods : Melittin and other peptide components were separated from bee venom by using gel filtration chromatography on Sephadex G-50 column in 0.05M ammonium acetate buffer. Results : Melittin and other peptide components were separated from bee venom by using gel filtration chromatography on Sephadex G-50 column in 0.05M ammonium acetate buffer. The fractions obtained from gel filtration chromatography was analyzed by using SDS-PAGE and propionic acid/urea polyacrylamide gel electrophoresis. The melittin obtained from the gel filtration contained residual amount of phospholipase A2 and a protein with molecular weight of 6,000. The contaminating proteins were removed by the second gel filtration chromatography. Conclusion : Gel filtration chromatography and propionic acid/urea polyacrylamide gel electrophoresis are useful to separate peptide components including melittin from bee venom.

  3. Self Cleaning HEPA Filtration without Interrupting Process Flow

    International Nuclear Information System (INIS)

    Wylde, M.

    2009-01-01

    The strategy of protecting the traditional glass fibre HEPA filtration train from it's blinding contamination and the recovery of dust by the means of self cleaning, pre-filtration is a proven means in the reduction of ultimate disposal volumes and has been used within the Fuel Production Industry. However, there is an increasing demand in nuclear applications requiring elevated operating temperatures, fire resistance, moisture resistance and chemical composition that the existing glass fibre HEPA filtration cannot accommodate, which can be remedied by the use of a metallic HEPA filter media. Previous research (Bergman et al 1997, Moore et al 1992) suggests that the then costs to the DOE, based on a five year life cycle, was $29.5 million for the installation, testing, removal and disposal of glass fibre HEPA filtration trains. Within these costs, $300 was the value given to the filter and $4,450 was given to the peripheral activity. Development of a low cost, cleanable, metallic, direct replacement of the traditional filter train will the clear solution. The Bergman et al work has suggested that a 1000 ft 3 /min, cleanable, stainless HEPA could be commercially available for $5,000 each, whereas the industry has determined that the truer cost of such an item in isolation would be closer to $15,000. This results in a conflict within the requirement between 'low cost' and 'stainless HEPA'. By proposing a system that combines metallic HEPA filtration with the ability to self clean without interrupting the process flow, the need for a tradition HEPA filtration train will be eliminated and this dramatically reduces the resources required for cleaning or disposal, thus presenting a route to reducing ultimate costs. The paper will examine the performance characteristics, filtration efficiency, flow verses differential pressure and cleanability of a self cleaning HEPA grade sintered metal filter element, together with data to prove the contention. (authors)

  4. MFTF-progress and promise

    International Nuclear Information System (INIS)

    Thomassen, K.I.

    1980-01-01

    The Mirror Fusion Test Facility (MFTF) has been in construction at Lawrence Livermore National Laboratory (LLNL) for 3 years, and most of the major subsystems are nearing completion. Recently, the scope of this project was expanded to meet new objectives, principally to reach plasma conditions corresponding to energy break-even. To fulfill this promise, the single-cell minimum-B mirror configuration will be replaced with a tandem mirror configuration (MFTF-B). The facility must accordingly be expanded to accomodate the new geometry. This paper briefly discusses the status of the major MFTF subsystems and describes how most of the technological objectives of MFTF will be demonstrated before we install the additional systems necessary to make the tandem. It also summarizes the major features of the expanded facility

  5. The promising opportunity of dismantlement

    International Nuclear Information System (INIS)

    Anon.

    2009-01-01

    Civil engineering, mechanics and waste conditioning companies are thriving around the market of nuclear facilities dismantlement which is promised to a huge development in the coming decade. This paper presents a map of the opportunities of the dismantlement market throughout Europe (research and power reactors, fuel fabrication plants, spent fuel reprocessing plants) and a cost estimation of a given dismantling work with respect to the different steps of the work. In France a small core of about twenty companies is involved in nuclear dismantlement but the French market is also looking towards foreign specialists of this activity. The British market is also targeted by the French companies but for all the actors the technological or commercial advance gained today will be determining for the future markets. (J.S.)

  6. Evaluation of human body irradiation caused by radionuclides deposited in the filtration unit of gas mask

    International Nuclear Information System (INIS)

    Cerny, R.; Otahal, P.; Johnova, K.; Thinova, L.; Kluson, J.

    2017-01-01

    Radioactive aerosol particles represent a serious risk for people facing the consequences of nuclear accident of any kind. The first responders to emergency situation need to be protected by personal protective equipment which includes radiation protection suit supplemented with gas mask. The purpose of this work is to estimate the dose to the organs of responder s body as a result of radionuclide deposition in the filtration unit of the gas mask. The problem was analyzed using Monte Carlo simulations. The dose absorbed by different organs for five representative radionuclides and the dose distribution over the responder s body are presented in this paper. Based on presented MC simulations, we suggest a method of evaluating the irradiation of the responder by the radionuclides deposited in the filtration unit of the gas mask. (authors)

  7. Air Filtration as Protection against Fouling of Ventilation and Air Conditioning Units

    DEFF Research Database (Denmark)

    Bekö, Gabriel; Lajčíková, Ariana

    2005-01-01

    Currently, air filters are one of the most critical components of air treatment systems as they decontaminate the air delivered to living space. During the operation, however, the level of harmful surface deposits increases, and at certain times, an uncleaned filter can itself become a source...... of undesirable contaminents influencing negatively the IAQ of a living space. This is the phenomenon that has been a subject of the current research. The article presents a new, alternative view on indoor air contaminents and filtration requirements. It describes alternative means of filtration and assesses...... issues of inadequate maintenance and/or long term use of applied air filters. An experimental method of evealuating the air quality by means of chemical analysis and state-of-the-art spectrometer is also described....

  8. Industrial application of liquid steel filtration out of dispersed nonmetallic phase in the continuous casting machine

    Directory of Open Access Journals (Sweden)

    K. Janiszewski

    2013-01-01

    Full Text Available Hitherto existing investigations concerning the ceramic filter use in the steel making processes (both of laboratory and industrial scale have given good results. The obtained results of filtration (in the laboratory have proved that this method may be used as an effective and cheap way of steel filtration from non-metallic inclusions. Placing filters in the tundish is the best location in consideration of limiting the possibility of secondary pollution of steel. Yet, the results presented in this paper, of an experiment prepared and carried out in the industrial environment, are the only positive results obtained, which are connected with so much quantities of liquid steel processed with use of the multi-hole ceramic filters.

  9. Novel antimony doped tin oxide/carbon aerogel as efficient electrocatalytic filtration membrane

    Directory of Open Access Journals (Sweden)

    Zhimeng Liu

    2016-05-01

    Full Text Available A facile method was developed to prepare antimony doped tin oxide (Sb-SnO2/carbon aerogel (CA for use as an electrocatalytic filtration membrane. The preparation process included synthesis of a precursor sol, impregnation, and thermal decomposition. The Sb-SnO2, which was tetragonal in phase with an average crystallite size of 10.8 nm, was uniformly distributed on the CA surface and firmly attached via carbon-oxygen-tin chemical bonds. Preliminary filtration tests indicated that the Sb-SnO2/CA membrane had a high rate of total organic carbon removal for aqueous tetracycline owing to its high current efficiency and electrode stability.

  10. AN AMELIORATED DETECTION STATISTICS FOR ADAPTIVE MASK MEDIAN FILTRATION OF HEAVILY NOISED DIGITAL IMAGES

    Directory of Open Access Journals (Sweden)

    Geeta Hanji

    2016-11-01

    Full Text Available Noise reduction is an important area of research in image processing applications. The performance of the digital image noise filtering method primarily depends upon the accuracy of noise detection scheme. This paper presents an effective detector based, adaptive mask, median filtration of heavily noised digital images affected with fixed value (or salt and pepper impulse noise. The proposed filter presents a novel approach; an ameliorated Rank Ordered Absolute Deviation (ROAD statistics to judge whether the input pixel is noised or noise free. If a pixel is detected as corrupted, it is subjected to adaptive mask median filtration; otherwise, it is kept unchanged. Extensive experimental results and comparative performance evaluations demonstrate that the proposed filter outperforms the existing decision type, median based filters with powerful noise detectors in terms of objective performance measures and visual retrieviation accuracy.

  11. A clinical comparison of image quality and patient exposure reduction in panoramic radiography with heavy metal filtration

    International Nuclear Information System (INIS)

    Kapa, S.F.; Tyndall, D.A.

    1989-01-01

    Laboratory and clinical studies with the use of rare earth intensifying screens and four different forms of heavy metal elements serving as additional beam filtration were performed for panoramic radiography to identify the most efficacious system. Balanced density images were evaluated for contrast indices, resolution, relative dose reduction, and subjective image quality. Clinical studies were performed with a standard calcium tungstate imaging system and the four most promising experimental imaging systems that showed improvement over the standard system. Dosimetric studies were performed with the use of ionization chambers and thermoluminescent dosimetry (TLD) dosimeters. Exposure reductions of 34% to 79%, depending on the anatomic site and the imaging system used, were achieved. Subjective image quality was evaluated and analyzed statistically. This study concluded that the use of a Kodak Lanex regular screen/T-Mat G film with either Lanex screen or yttrium added beam filtration results in reduced patient exposure in panoramic radiography while image quality is maintained or improved

  12. DQE of wireless digital detectors: Comparative performance with differing filtration schemes

    International Nuclear Information System (INIS)

    Samei, Ehsan; Murphy, Simon; Christianson, Olav

    2013-01-01

    Purpose: Wireless flat panel detectors are gaining increased usage in portable medical imaging. Two such detectors were evaluated and compared with a conventional flat-panel detector using the formalism of the International Electrotechnical Commission (IEC 62220-1) for measuring modulation transfer function (MTF), normalized noise power spectrum (NNPS), and detective quantum efficiency (DQE) using two different filtration schemes.Methods: Raw images were acquired for three image receptors (DRX-1C and DRX-1, Carestream Health; Inc., Pixium 4600, Trixell) using a radiographic system with a well-characterized output (Philips Super80 CP, Philips Healthcare). Free in-air exposures were measured using a calibrated radiation meter (Unfors Mult-O-Meter Type 407, Unfors Instruments AB). Additional aluminum filtration and a new alternative combined copper-aluminum filtration were used to conform the x ray output to IEC-specified beam quality definitions RQA5 and RQA9. Using the IEC 62220-1 formalism, each detector was evaluated at X N /2, X N , and 2X N , where the normal exposure level to the detector surface (X N ) was set to 8.73 μGy (1.0 mR). The prescribed edge test device was used to evaluate the MTF, while the NNPS was measured using uniform images. The DQE was then calculated from the MTF and NNPS and compared across detectors, exposures, and filtration schemes.Results: The three DR systems had largely comparable MTFs with DRX-1 demonstrating lower values above 1.0 cycles/mm. At each exposure, DRX-1C and Pixium detectors demonstrated better noise performance than that of DRX-1. Zero-frequency DQEs for DRX-1C, Pixium, and DRX-1 detectors were approximately 74%, 63%, and 38% for RQA5 and 50%, 42%, and 28% for RQA9, respectively.Conclusions: DRX-1C detector exhibited superior DQE performance compared to Pixium and DRX-1. In terms of filtration, the alternative filtration was found to provide comparable performance in terms of rank ordering of different detectors with

  13. DQE of wireless digital detectors: Comparative performance with differing filtration schemes

    Energy Technology Data Exchange (ETDEWEB)

    Samei, Ehsan [Carl E. Ravin Advanced Imaging Laboratories, Departments of Radiology, Biomedical Engineering, Physics, and Electrical and Computer Engineering, Medical Physics Graduate Program, Duke University Medical Center, Durham, North Carolina 27705 (United States); Murphy, Simon; Christianson, Olav [Medical Physics Graduate Program, Duke University, Durham, North Carolina 27705 (United States)

    2013-08-15

    Purpose: Wireless flat panel detectors are gaining increased usage in portable medical imaging. Two such detectors were evaluated and compared with a conventional flat-panel detector using the formalism of the International Electrotechnical Commission (IEC 62220-1) for measuring modulation transfer function (MTF), normalized noise power spectrum (NNPS), and detective quantum efficiency (DQE) using two different filtration schemes.Methods: Raw images were acquired for three image receptors (DRX-1C and DRX-1, Carestream Health; Inc., Pixium 4600, Trixell) using a radiographic system with a well-characterized output (Philips Super80 CP, Philips Healthcare). Free in-air exposures were measured using a calibrated radiation meter (Unfors Mult-O-Meter Type 407, Unfors Instruments AB). Additional aluminum filtration and a new alternative combined copper-aluminum filtration were used to conform the x ray output to IEC-specified beam quality definitions RQA5 and RQA9. Using the IEC 62220-1 formalism, each detector was evaluated at X{sub N}/2, X{sub N}, and 2X{sub N}, where the normal exposure level to the detector surface (X{sub N}) was set to 8.73 μGy (1.0 mR). The prescribed edge test device was used to evaluate the MTF, while the NNPS was measured using uniform images. The DQE was then calculated from the MTF and NNPS and compared across detectors, exposures, and filtration schemes.Results: The three DR systems had largely comparable MTFs with DRX-1 demonstrating lower values above 1.0 cycles/mm. At each exposure, DRX-1C and Pixium detectors demonstrated better noise performance than that of DRX-1. Zero-frequency DQEs for DRX-1C, Pixium, and DRX-1 detectors were approximately 74%, 63%, and 38% for RQA5 and 50%, 42%, and 28% for RQA9, respectively.Conclusions: DRX-1C detector exhibited superior DQE performance compared to Pixium and DRX-1. In terms of filtration, the alternative filtration was found to provide comparable performance in terms of rank ordering of different

  14. Experimental study on filtration and continuous regeneration of a particulate filter system for heavy-duty diesel engines.

    Science.gov (United States)

    Tang, Tao; Zhang, Jun; Cao, Dongxiao; Shuai, Shijin; Zhao, Yanguang

    2014-12-01

    This study investigated the filtration and continuous regeneration of a particulate filter system on an engine test bench, consisting of a diesel oxidation catalyst (DOC) and a catalyzed diesel particulate filter (CDPF). Both the DOC and the CDPF led to a high conversion of NO to NO2 for continuous regeneration. The filtration efficiency on solid particle number (SPN) was close to 100%. The post-CDPF particles were mainly in accumulation mode. The downstream SPN was sensitively influenced by the variation of the soot loading. This phenomenon provides a method for determining the balance point temperature by measuring the trend of SPN concentration. Copyright © 2014. Published by Elsevier B.V.

  15. Spontaneous water filtration of bio-inspired membrane

    Science.gov (United States)

    Kim, Kiwoong; Kim, Hyejeong; Lee, Sang Joon

    2016-11-01

    Water is one of the most important elements for plants, because it is essential for various metabolic activities. Thus, water management systems of vascular plants, such as water collection and water filtration have been optimized through a long history. In this view point, bio-inspired technologies can be developed by mimicking the nature's strategies for the survival of the fittest. However, most of the underlying biophysical features of the optimized water management systems remain unsolved In this study, the biophysical characteristics of water filtration phenomena in the roots of mangrove are experimentally investigated. To understand water-filtration features of the mangrove, the morphological structures of its roots are analyzed. The electrokinetic properties of the root surface are also examined. Based on the quantitatively analyzed information, filtration of sodium ions in the roots are visualized. Motivated by this mechanism, spontaneous desalination mechanism in the root of mangrove is proposed by combining the electrokinetics and hydrodynamic transportation of ions. This study would be helpful for understanding the water-filtration mechanism of the roots of mangrove and developing a new bio-inspired desalination technology. This research was financially supported by the National Research Foundation (NRF) of Korea (Contract Grant Number: 2008-0061991).

  16. Water quality and treatment of river bank filtrate

    Directory of Open Access Journals (Sweden)

    W. W. J. M. de Vet

    2010-06-01

    Full Text Available In drinking water production, river bank filtration has the advantages of dampening peak concentrations of many dissolved components, substantially removing many micropollutants and removing, virtually completely, the pathogens and suspended solids. The production aquifer is not only fed by the river bank infiltrate but also by water percolating through covering layers. In the polder areas, these top layers consist of peat and deposits from river sediments and sea intrusions.

    This paper discusses the origin and fate of macro components in river bank filtrate, based on extensive full-scale measurements in well fields and treatment systems of the Drinking Water Company Oasen in the Netherlands. First, it clarifies and illustrates redox reactions and the mixing of river bank filtrate and PW as the dominant processes determining the raw water quality for drinking water production. Next, full-scale results are elaborated on to evaluate trickling filtration as an efficient and proven one-step process to remove methane, iron, ammonium and manganese. The interaction of methane and manganese removal with nitrification in these systems is further analyzed. Methane is mostly stripped during trickling filtration and its removal hardly interferes with nitrification. Under specific conditions, microbial manganese removal may play a dominant role.

  17. Oviposition Attractancy of Bacterial Culture Filtrates: response of Culex quinquefasciatus

    Directory of Open Access Journals (Sweden)

    S Poonam

    2002-04-01

    Full Text Available Oviposition attractants could be used for monitoring as well as controlling mosquitoes by attracting them to lay eggs at chosen sites. In the present study, culture filtrates of seven bacterial species were tested for their attractancy against gravid females of Culex quinquefasciatus. When their oviposition active indices (OAI were studied, the culture filtrates of Bacillus cereus and Pseudomonas fluorescens exhibited oviposition attractancy (OAI = >0.3 at 100 ppm and the OAI were respectively 0.70 and 0.47. Culture filtrates of B. thuringiensis var. israelensis (wild type, B. t. var. israelensis (mutant and B. sphaericus showed attractancy at 2000 ppm with OAI of respectively 0.71, 0.59 and 0.68. However, the OAI of B. megaterium as well as Azospirillum brasilense was 0.13 (at 2000 ppm, which was less than 0.3 required to be considered them as attractants. When the oviposition attractancy of the bacterial culture filtrates were compared with that of a known oviposition attractant, p-cresol (at 10 ppm, the culture filtrates of B. t. var. israelensis (wild type and B. cereus were found to be more active than p-cresol, respectively with 64.2 and 54.3% oviposition.

  18. Impact of Acidification on Pollutants Fate and Soil Filtration Function

    Directory of Open Access Journals (Sweden)

    Jarmila Makovniková

    2014-12-01

    Full Text Available The objective of this paper was to investigate the effects of simulated acid load on the fate of inorganic pollutants (Cd, Pb, soil sorption potential, soil filtration func-tion. We made use of a short-term acidification pot experiment with grown plant of spring barley cultivated at 4 different soil types (Fluvisol, Cambisol, Stagnosol, Podzol. The potential of soil filtration was evaluated according to the Eq.: [Soil filtration function]=[Potential of soil sorbents]+[Potential of total content of inor-ganic pollutants]. Potential of soil sorbents (PSS is defined by qualitative (pH, or-ganic matter quality - A400/600 and quantitative factors (carbon content-Cox, humus layer thickness-H according to the Eq.:[PSS]=F(pH+F(A465/665+F(Cox*F(H. Acid load significantly influenced soil sorption potential and thus affected increase in Cd and Pb mobility what was reflected in their transfer into the plants. Results of soil filtration function showed significant change of filtration function in Cambisol.

  19. Relationships between the physical forms of starch and performance of carbonatation clarification and press filtration at the refinery

    Science.gov (United States)

    Laboratory studies were conducted to underpin if and how the different physical forms of starch (insoluble or soluble) affected carbonatation clarification and press filtration, by using simulated melt liquors. Carbonatated liquors containing =250 ppm/Brix (USDA starch research method) of total sta...

  20. Effect of flood-induced chemical load on filtrate quality at bank filtration sites

    Science.gov (United States)

    Ray, C.; Soong, T.W.; Lian, Y.Q.; Roadcap, G.S.

    2002-01-01

    Riparian municipal wells, that are located on riverbanks, are specifically designed to capture a portion of the river water through induced infiltration. Runoff from agricultural watersheds is found to carry enormous amounts of pesticides and nitrate. While the risk of contamination for a vast majority of sites with small-capacity vertical wells is low, potential exists for medium to large capacity collector wells to capture a fraction of the surface water contaminants during flood. Prior monitoring and current modeling results indicate that a small-capacity (peak pumpage 0.0315 m3/s) vertical bank filtration well may not be affected by river water nitrate and atrazine even during flood periods. For a medium capacity (0.0875-0.175 m3/s) hypothetical collector well at the same site, potential exists for a portion of the river water nitrate and atrazine to enter the well during flood periods. Various combinations of hydraulic conductivity of the riverbed or bank material were used. For nitrate, it was assumed either no denitrification occurred during the period of simulation or a half-life of 2 years. Equilibrium controlled sorption (organic carbon partition coefficient of 52 ml/g) and a half-life of between 7.5 and 15 weeks were considered for atrazine. Combinations of these parameters were used in various simulations. Peak concentrations of atrazine or nitrate in pumped water could vary from less than 1% to as high as 90% of that in the river. It was found that a combination of river stage, pumping rates, hydraulic properties of the riverbed and bank, and soil/pesticide properties could affect contaminant entry from river water to any of these wells. If the hydraulic conductivity of the bed and bank material were low, atrazine would not reach the pumping well with or without sorption and degradation. However, for moderately low permeable bank and bed materials, some atrazine from river water could enter a hypothetical collector well while pumping at 0.0875 m3/s. It

  1. C-018H LERF filtration test plan. Revision 1

    International Nuclear Information System (INIS)

    Moberg, T.P.; King, C.V.

    1994-01-01

    The following outlines the plan to test the polymeric backwash filtration system at the LERF. These tests will determine if the ETF filter design is adequate. If the tests show that the design is adequate, the task will be complete. If the tests show that the technology is inadequate, it may be necessary to perform further tests to qualify other candidate filtration technologies (e.g., polymeric tubular ultrafiltration, centrifugal ultrafiltration). The criteria to determine the success or failure of the backwash filter will be based on the system's ability to remove the bacteria and inorganic contaminants from the evaporator process condensate. The tests are designed to qualify the design basis of the filtration technology that will be used in the ETF

  2. Landfill Leachate Treatment by Electrocoagulation and Fiber Filtration.

    Science.gov (United States)

    Li, Runwei; Wang, Boya; Owete, Owete; Dertien, Joe; Lin, Chen; Ahmad, Hafiz; Chen, Gang

    2017-11-01

      Landfilling is widely adopted as one of the most economical processes for solid waste disposal. At the same time, landfill leachate is also a great environmental concern owing to its complex composition and high concentrations of contaminants. This research investigated electrocoagulation and fiber filtration for the treatment of landfill leachate. Besides electrical current (i.e., current density) and reaction time, pH played a very important role in arsenic and phosphorus removal by electrocoagulation. The combination of electrocoagulation with fiber filtration achieved a 94% chemical oxygen demand (COD), 87% arsenic, 96% iron, and 86% phosphorus removal. During electrocoagulation, the micro-particles that could not be settled by gravity were removed by the first stage of fiber filtration. Organic contaminants in the leachate were further removed by biodegradation in the second stage of fiber biofiltration.

  3. Efektifitas Riverbank Filtration Trhadap Parameter Fisik (TDS di Sungai Cihideung

    Directory of Open Access Journals (Sweden)

    Roh Santoso Budi Waspodo

    2013-01-01

    Full Text Available Water is a natural resource that is necessary for the livelihood of many people, even by all living things. Data Ministry of Public Works in 2006 mentions the availability of water in Indonesia amounted to 15,500 cubic meters per capita per year, far higher than the global availability averaged only 600 m3. If drawn, the amount of water covers 21% of Indonesia Pacific Ocean. However, the overflow Indonesia does not necessarily solve the problem of water crisis which is also predicted to fall on two major islands in 2015. The general objective of this research is to develop and implement technological innovations RBF (Riverbank Filtration to support the needs of irrigation water Watershed Cisadane, making RBF (Riverbank Filtration as a natural water treatment in Cisadane River area, and water quality data information through RBF (Riverbank Filtration Cisadane Watershed.

  4. C-018H LERF filtration test plan. Revision 1

    Energy Technology Data Exchange (ETDEWEB)

    Moberg, T.P.; King, C.V.

    1994-08-26

    The following outlines the plan to test the polymeric backwash filtration system at the LERF. These tests will determine if the ETF filter design is adequate. If the tests show that the design is adequate, the task will be complete. If the tests show that the technology is inadequate, it may be necessary to perform further tests to qualify other candidate filtration technologies (e.g., polymeric tubular ultrafiltration, centrifugal ultrafiltration). The criteria to determine the success or failure of the backwash filter will be based on the system`s ability to remove the bacteria and inorganic contaminants from the evaporator process condensate. The tests are designed to qualify the design basis of the filtration technology that will be used in the ETF.

  5. Simulations of Microbial-Enhanced Oil Recovery: Adsorption and Filtration

    DEFF Research Database (Denmark)

    Nielsen, Sidsel Marie; Nesterov, Igor; Shapiro, Alexander

    2014-01-01

    In the context of microbial-enhanced oil recovery (MEOR) with injection of surfactant-producing bacteria into the reservoir, different types of bacteria attachment and growth scenarios are studied using a 1D simulator. The irreversible bacteria attachment due to filtration similar to the deep bed...... applied to filtration model provides formation of two oil banks during recovery. This feature is not reproduced by application of REA model or DBF with growth in attached phase. This makes it possible to select a right model based on the qualitative analysis of the experimental data. A criterion...... is introduced to study the process efficiency: the dimensionless time at which average recovery between pure water injection and maximum surfactant effect is reached. This characteristic recovery period (CRP) was studied as a function of the different MEOR parameters such as bacterial activity, filtration...

  6. Fusion Kalman filtration with k-step delay sharing pattern

    Directory of Open Access Journals (Sweden)

    Duda Zdzisław

    2015-09-01

    Full Text Available A fusion hierarchical state filtration with k−step delay sharing pattern for a multisensor system is considered. A global state estimate depends on local state estimates determined by local nodes using local information. Local available information consists of local measurements and k−step delay global information - global estimate sent from a central node. Local estimates are transmitted to the central node to be fused. The synthesis of local and global filters is presented. It is shown that a fusion filtration with k−step delay sharing pattern is equivalent to the optimal centralized classical Kalman filtration when local measurements are transmitted to the center node and used to determine a global state estimate. It is proved that the k−step delay sharing pattern can reduce covariances of local state errors.

  7. Grey water treatment in urban slums by a filtration system: optimisation of the filtration medium.

    Science.gov (United States)

    Katukiza, A Y; Ronteltap, M; Niwagaba, C B; Kansiime, F; Lens, P N L

    2014-12-15

    Two uPVC columns (outer diameter 160 cm, internal diameter 14.6 cm and length 100 cm) were operated in parallel and in series to simulate grey water treatment by media based filtration at unsaturated conditions and constant hydraulic loading rates (HLR). Grey water from bathroom, laundry and kitchen activities was collected from 10 households in the Bwaise III slum in Kampala (Uganda) in separate containers, mixed in equal proportions followed by settling, prior to transferring the influent to the tanks. Column 1 was packed with lava rock to a depth of 60 cm, while column 2 was packed with lava rock (bottom 30 cm) and silica sand, which was later replaced by granular activated carbon (top 30 cm) to further investigate nutrient removal from grey water. Operating the two filter columns in series at a HLR of 20 cm/day resulted in a better effluent quality than at a higher (40 cm/day) HLR. The COD removal efficiencies by filter columns 1 and 2 in series amounted to 90% and 84% at HLR of 20 cm/day and 40 cm/day, respectively. TOC and DOC removal efficiency amounted to 77% and 71% at a HLR of 20 cm/day, but decreased to 72% and 67% at a HLR of 40 cm/day, respectively. The highest log removal of Escherichia coli, Salmonella sp. and total coliforms amounted to 3.68, 3.50 and 3.95 at a HLR of 20 cm/day respectively. The overall removal of pollutants increased with infiltration depth, with the highest pollutant removal efficiency occurring in the top 15 cm layer. Grey water pre-treatment followed by double filtration using coarse and fine media has the potential to reduce the grey water pollution load in slum areas by more than 60%. Copyright © 2014 Elsevier Ltd. All rights reserved.

  8. Polyaluminium chloride as an alternative to alum for the direct filtration of drinking water.

    Science.gov (United States)

    Zarchi, Idit; Friedler, Eran; Rebhun, Menahem

    2013-01-01

    The efficiency of various polyaluminium chloride coagulants (PACls) was compared to the efficiency of aluminium sulfate (alum) in the coagulation-flocculation process preceding direct filtration in drinking water treatment. The comparative study consisted of two separate yet complementary series of experiments: the first series included short (5-7 h) and long (24 h) filter runs conducted at a pilot filtration plant equipped with large filter columns that simulated full-scale filters. Partially treated surface water from the Sea of Galilee, characterized by very low turbidity (-1 NTU), was used. In the second series of experiments, speciation of aluminium in situ was investigated using the ferron assay method. Results from the pilot-scale study indicate that most PACls were as or more efficient a coagulant as alum for direct filtration of surface water without requiring acid addition for pH adjustment and subsequent base addition for re-stabilizing the water. Consequently, cost analysis of the chemicals needed for the process showed that treatment with PACl would be significantly less costly than treatment with alum. The aluminium speciation experiments revealed that the performance of the coagulant is more influenced by the species present during the coagulation process than those present in the original reagents.

  9. ACTINIDE REMOVAL PROCESS SAMPLE ANALYSIS, CHEMICAL MODELING, AND FILTRATION EVALUATION

    Energy Technology Data Exchange (ETDEWEB)

    Martino, C.; Herman, D.; Pike, J.; Peters, T.

    2014-06-05

    Filtration within the Actinide Removal Process (ARP) currently limits the throughput in interim salt processing at the Savannah River Site. In this process, batches of salt solution with Monosodium Titanate (MST) sorbent are concentrated by crossflow filtration. The filtrate is subsequently processed to remove cesium in the Modular Caustic Side Solvent Extraction Unit (MCU) followed by disposal in saltstone grout. The concentrated MST slurry is washed and sent to the Defense Waste Processing Facility (DWPF) for vitrification. During recent ARP processing, there has been a degradation of filter performance manifested as the inability to maintain high filtrate flux throughout a multi-batch cycle. The objectives of this effort were to characterize the feed streams, to determine if solids (in addition to MST) are precipitating and causing the degraded performance of the filters, and to assess the particle size and rheological data to address potential filtration impacts. Equilibrium modelling with OLI Analyzer{sup TM} and OLI ESP{sup TM} was performed to determine chemical components at risk of precipitation and to simulate the ARP process. The performance of ARP filtration was evaluated to review potential causes of the observed filter behavior. Task activities for this study included extensive physical and chemical analysis of samples from the Late Wash Pump Tank (LWPT) and the Late Wash Hold Tank (LWHT) within ARP as well as samples of the tank farm feed from Tank 49H. The samples from the LWPT and LWHT were obtained from several stages of processing of Salt Batch 6D, Cycle 6, Batch 16.

  10. Estimated glomerular filtration rate in patients with type 2 diabetes mellitus

    Directory of Open Access Journals (Sweden)

    Paula Caitano Fontela

    2014-12-01

    Full Text Available Objective: to estimate the glomerular filtration using the Cockcroft-Gault (CG, Modification of Diet in Renal Disease (MDRD, and Chronic Kidney Disease Epidemiology Collaboration (CKD-EPI equations, and serum creatinine in the screening of reduced renal function in patients with type two diabetes (T2DM enrolled in the Family Health Strategy (ESF, Brazilian federal health-care program. Methods: a cross-sectional descriptive and analytical study was conducted. The protocol consisted of sociodemographics, physical examination and biochemical tests. Renal function was analyzed through serum creatinine and glomerular filtration rate (GFR estimated according to the CG, MDRD and CKD-EPI equations, available on the websites of the Brazilian Nephrology Society (SBN and the (NKF. Results: 146 patients aged 60.9±8.9 years were evaluated; 64.4% were women. The prevalence of serum creatinine >1.2 mg/dL was 18.5% and GFR <60 mL/min/1.73m2 totaled 25.3, 36.3 and 34.2% when evaluated by the equations CG, MDRD and CKD-EPI, respectively. Diabetic patients with reduced renal function were older, had long-term T2DM diagnosis, higher systolic blood pressure and higher levels of fasting glucose, compared to diabetics with normal renal function. Creatinine showed strong negative correlation with the glomerular filtration rate estimated using CG, MDRD and CKD-EPI (-0.64, -0.87, -0.89 equations, respectively. Conclusion: the prevalence of individuals with reduced renal function based on serum creatinine was lower, reinforcing the need to follow the recommendations of the SBN and the National Kidney Disease Education Program (NKDEP in estimating the value of the glomerular filtration rate as a complement to the results of serum creatinine to better assess the renal function of patients.

  11. FLUX ENHANCEMENT IN CROSSFLOW MEMBRANE FILTRATION: FOULING AND IT'S MINIMIZATION BY FLOW REVERSAL

    International Nuclear Information System (INIS)

    Shamsuddin Ilias

    2005-01-01

    Fouling problems are perhaps the single most important reason for relatively slow acceptance of ultrafiltration in many areas of chemical and biological processing. To overcome the losses in permeate flux associated with concentration polarization and fouling in cross flow membrane filtration, we investigated the concept of flow reversal as a method to enhance membrane flux in ultrafiltration. Conceptually, flow reversal prevents the formation of stable hydrodynamic and concentration boundary layers at or near the membrane surface. Further more, periodic reversal of the flow direction of the feed stream at the membrane surface results in prevention and mitigation of membrane fouling. Consequently, these advantages are expected to enhance membrane flux significantly. A crossflow membrane filtration unit was designed and built to test the concept of periodic flow reversal for flux enhancement. The essential elements of the system include a crossflow hollow fiber membrane module integrated with a two-way valve to direct the feed flow directions. The two-way valve is controlled by a controller-timer for periodic reversal of flow of feed stream. Another important feature of the system is that with changing feed flow direction, the permeate flow direction is also changed to maintain countercurrent feed and permeate flows for enhanced mass transfer driving force (concentration difference). In this report, we report our application of Flow Reversal technique in clarification of apple juice containing pectin. The presence of pectin in apple juice makes the clarification process difficult and is believed to cause membrane fouling. Of all compounds found in apple juice, pectin is most often identified as the major hindrance to filtration performance. Based on our ultrafiltration experiments with apple juice, we conclude that under flow reversal conditions, the permeate flux is significantly enhanced when compared with the conventional unidirectional flow. Thus, flow reversal

  12. Air filtration media from electrospun waste high-impact polystyrene fiber membrane

    Science.gov (United States)

    Zulfi, Akmal; Miftahul Munir, Muhammad; Hapidin, Dian Ahmad; Rajak, Abdul; Edikresnha, Dhewa; Iskandar, Ferry; Khairurrijal, Khairurrijal

    2018-03-01

    Nanofiber membranes were synthesized from waste high-impact polystyrene (HIPS) using electrospinning method and then applied as air filtration media. The waste HIPS precursor solution with the concentration of 20 wt.% was prepared by dissolving waste HIPS into the mixture of d-limonene and DMF solvents. Beaded or fine nanofibers could be achieved by adjusting the ratio of solvents mixture (d-limonene and DMF). Using the ratios of solvents (d-limonene: DMF) of 3:1, 1:1, and 1:3, it was obtained beaded HIPS nanofibers with the average diameter of 272 nm, beaded HIPS nanofibers with the average diameter of 937, and fine HIPS nanofibers with the average diameter of 621 nm, respectively. From the FTIR spectral analysis, it was found that the FTIR peaks of the HIPS nanofiber membranes are the same as those of the cleaned waste HIPS and there are no FTIR peaks of DMF and d-limonene solvents. These findings implied that the electrospinning process allows the recycling of waste HIPS into HIPS nanofibers without any trapped solvent phases or apparent degradation of the original material. From the contact angle measurement, it was confirmed that the HIPS nanofiber membranes are hydrophobic and the presence of the beads in the HIPS nanofiber membranes varies their contact angles. From the air-filtration test, it was shown that the fiber morphology (beaded or fine nanofibers) considerably affects the filtration performance of the membranes. The presence of beads increased the distance between the fibers so that the pressure drop decreased. Moreover, the basis weight of the membrane greatly affected the filtration efficiency. The HIPS nanofiber membrane with the basis weight of 12.22 g m‑2 had the efficiency greater than 99.999%, which was equivalent to that of the HEPA filter.

  13. Hydrous iron oxide modified diatomite as an active filtration medium for phosphate capture.

    Science.gov (United States)

    Wang, Zhe; Lin, Yan; Wu, Deyi; Kong, Hainan

    2016-02-01

    A simple method to functionalize diatomite with hydrous iron oxide was attempted and its performance as a new active filtration material to remove and recover phosphate from water was investigated under varying solution conditions. The Langmuir phosphate adsorption capacity increased from 0.6 mgP/g for raw diatomite to 4.89, 14.71, 25.02 mgP/g for hydrous iron oxide modified diatomite (HIOMD), depending on the amount of iron loaded. Loading of hydrous iron oxide caused the increase in true and bulk density and a decline in filtration rate, but to a lesser extent. It was shown that the HIOMD product with suitable iron content could retain a good filtration performance with a greatly increased adsorption capacity for phosphate. The phosphate adsorption increased by decreasing pH and by increasing ionic strength at high pH levels. The adsorption process was interpreted by ligand exchange. Coexisting oxyanions of sulfate, nitrate, citrate, carbonate, silicate and humic acid showed different effects on phosphate fixation but it was presumed that their influence at their concentrations and pH levels commonly encountered in effluent or natural waters was limited, i.e., HIOMD had a reasonably good selectivity. Results in repeated adsorption, desorption and regeneration experiment showed that the adsorbed phosphate could be recovered and the material could be reused after regeneration. The column test showed that HIOMD could be potentially utilized as an adsorption filtration medium for phosphate removal and recovery from water. Copyright © 2015 Elsevier Ltd. All rights reserved.

  14. Graphite beds for coolant filtration at high temperature

    International Nuclear Information System (INIS)

    Heathcock, R.E.; Lacy, C.S.

    1978-01-01

    High temperature filtration will be provided for new Ontario Hydro CANDU heat transport systems. Filtration has been shown to effectively reduce the concentration of circulating corrosion products in our heat transport systems, hence, minimizing the processes of activity transport. This paper will present one option we have for this application; Deep Bed Granular Graphite Filters. The filter system is described by discussing pertinent aspects of its development programme. The compatibility of the filter and the heat transport coolant are demonstrated by results from loop tests, both out- and in-reactor, and by subsequent results from a large filter installation in the NPD NGS heat transport system. (author)

  15. Pathogen filtration to control plant disease outbreak in greenhouse production

    Science.gov (United States)

    Jeon, Sangho; Krasnow, Charles; Bhalsod, Gemini; Granke, Leah; Harlan, Blair; Hausbeck, Mary; Zhang, Wei

    2016-04-01

    Previous research has been extensively focused on understanding the fate and transport of human microbial pathogens in soil and water environments. However, little is known about the transport of plant pathogens, although these pathogens are often found in irrigation waters and could cause severe crop damage and economical loss. Water mold pathogens including Phytophthora spp. and Pythium spp. are infective to a wide range of vegetable and floriculture crops, and they are primarily harbored in soils and disseminated through water flow. It is challenging to control these pathogens because they often quickly develop resistance to many fungicides. Therefore, this multi-scale study aimed to investigate physical removal of plant pathogens from water by filtration, thus reducing the pathogen exposure risks to crops. In column-scale experiments, we studied controlling factors on the transport and retention of Phytophthora capsici zoospores in saturated columns packed with iron oxide coated-sand and uncoated-sand under varying solution chemistry. Biflagellate zoospores were less retained than encysted zoospores, and lower solution pH and greater iron oxide content increased the retention of encysted zoospores. These results provided insights on environmental dispersal of Phytophthora zoospores in natural soils as well as on developing cost-effective engineered filtration systems for pathogen removal. Using small-scale greenhouse filtration systems, we further investigated the performance of varying filter media (i.e., granular sand, iron oxide coated ceramic porous media, and activated carbon) in mitigating disease outbreaks of Phytophthora and Pythium for greenhouse-grown squash and poinsettia, respectively, in comparison with fungicide treatment. For squash, filtration by iron oxide coated media was more effective in reducing the Phytophthora infection, comparing to sand filtration and fungicide application. For poinsettia, sand filtration performed better in controlling

  16. Clinical dehydration and glomerular filtration rate in acute paediatric gastroenteritis.

    Science.gov (United States)

    Milani, Gregorio P; Fossali, Emilio F; Perri, Alessandra; Vettori, Arianna; Grillo, Paolo; Agostoni, Carlo

    2013-08-01

    To evaluate changes in glomerular filtration rate in acute gastroenteritis. The correlation between two clinical diagnostic scales and glomerular filtration rate has been investigated in 113 children with acute gastroenteritis in a paediatric emergency setting. A significant reduction of GFR was found in 10% children less than, and 5% children higher than, 2 years of age with acute gastroenteritis. The differences observed as for risk of renal hypoperfusion suggests to consider the age of children as an important determinant to consider the dehydration status in acute gastroenteritis. ©2013 Foundation Acta Paediatrica. Published by John Wiley & Sons Ltd.

  17. SUSPENSION-FEEDING IN MARINE SPONGES HALICHONDRIA-PANICEA AND HALICLONA-URCEOLUS - EFFECTS OF TEMPERATURE ON FILTRATION-RATE AND ENERGY-COST OF PUMPING

    DEFF Research Database (Denmark)

    Riisgård, H.U.; Thomassen, S.; Jakobsen, H.

    1993-01-01

    Filtration rate (measured as clearance of algal cells) was measured at different temperatures in the sponge Halichondria panicea. An increase in water temperature from 6 to 12-degrees-C caused the mean filtration rate to increase 4.3 +/- 2.3 times. This value was higher than previously found...... for other marine ciliary suspension-feeding animals. Filtration rate at 12-degrees-C was also measured in Haliclona urceolus by means of an indirect clearance method in addition to a direct technique for measuring pumping rate. It was found that the 2 sponge species had near-identical filtration rates......, with maximum rates of approximately 60 ml min-1 (g dry weight)-1 at 12-degrees-C. The normal pump pressure, or operating point O(p), of a standard sponge (based on our own measurements and calculations from literature data for a 0.1 g dry weight Haliclona sp.) was estimated as the sum of main contributions...

  18. Filtration of Oil-furnace Carbon Black Dust Particles from the Tail Gases by Filter Bags With PTFE Membrane

    Directory of Open Access Journals (Sweden)

    Čuzela, D.

    2010-01-01

    Full Text Available During the industrial production of oil furnace carbon black, tail gases containing oil-furnace carbon black dust particles are emitted to the atmosphere. In the carbon black plant, Petrokemija d. d., there are six exhaust stacks for tail gases. Each of them has installed process equipment for cleaning tail gases. Efficiency of cleaning mainly depends on equipment construction and cleaning technology. The vicinity of the town, quality of the air in the region of Kutina, regarding floating particles PM10, and corporate responsibility for further enviromental improvement, imposes development of new methods that will decrease the emmision of oil-furnace carbon black dust particles in the air. Combining centrifugal percipitator and filter, special construction of cyclofilter for filtration of oil-furnace carbon black dust particles from tail gases by using PTFE (polytetrafluoroethylene membrane filter bags, was designed. Developed filtration technique provides η = 99.9 % efficiency of filtration. Construction part of the filter contains the newest generation of PTFE membrane filter bags with the ability of jet pulse cleaning. Using the PTFE membrane filter bags technology, filtration efficiency for oil-furnace carbon black dust particles in tail gases of maximum γ=5mgm-3can be achieved. The filtration efficiency was monitored continuously measuring the concentration of the oil-furnace carbon black dust particles in the tail gases with the help of in situ electronic probe. The accomplished filtration technology is the base for the installation of the PTFE membrane filter bags in the main operation filters which will provide better protection of the air in the town of Kutina against floating particles PM10.

  19. SU-D-209-02: Percent Depth Dose Curves for Fluoroscopic X-Ray Beam Qualities Incorporating Copper Filtration

    Energy Technology Data Exchange (ETDEWEB)

    Wunderle, K [Cleveland Clinic Foundation, Cleveland, OH (United States); Wayne State University School of Medicine, Detroit, MI (United States); Godley, A; Shen, Z; Dong, F [Cleveland Clinic Foundation, Cleveland, OH (United States); Rakowski, J [Wayne State University School of Medicine, Detroit, MI (United States)

    2016-06-15

    Purpose: The purpose of this investigation was to quantify percent depth dose (PDD) curves for fluoroscopic x-ray beam qualities incorporating added copper filtration. Methods: A PTW (Freiburg, Germany) MP3 water tank was used with a Standard Imaging (Middleton, WI) Exradin Model 11 Spokas Chamber to measure PDD curves for 60, 80, 100 and 120 kVp x-ray beams with copper filtration ranging from 0.0–0.9 mm at 22cm and 42cm fields of view from 0 to 150 mm of water. A free-in-air monitor chamber was used to normalize the water tank data to fluctuations in output from the fluoroscope. The measurements were acquired on a Siemens (Erlangen, Germany) Artis ZeeGo fluoroscope. The fluoroscope was inverted from the typical orientation providing an x-ray beam originating from above the water tank. The water tank was positioned so that the water level was located at 60cm from the focal spot; which also represents the focal spot to interventional reference plane distance for that fluoroscope. Results: PDDs for 60, 80, 100, and 120 kVp with 0 mm of copper filtration compared well to previously published data by Fetterly et al. [Med Phys, 28, 205 (2001)] for those beam qualities given differences in fluoroscopes, geometric orientation, type of ionization chamber, and the water tank used for data collection. PDDs for 60, 80, 100, and 120 kVp with copper filtration were obtained and are presented, which have not been previously investigated and published. Conclusion: The equipment and processes used to acquire the reported data were sound and compared well with previously published data for PDDs without copper filtration. PDD data for the fluoroscopic x-ray beams incorporating copper filtration can be used as reference data for estimating organ or soft tissue dose at depth involving similar beam qualities or for comparison with mathematical models.

  20. Analysis of promising sustainable renovation concepts

    DEFF Research Database (Denmark)

    Vanhoutteghem, Lies; Tommerup, Henrik M.; Svendsen, Svend

    This report focuses on analyses of the most promising existing sustainable renovation concepts, i.e. full-service concepts and technical concepts, for single-family houses. As a basis for the analyses a detailed building stock analysis was carried out. Furthermore, as a basis a general working...... method for proposals on package solutions for sustainable renovation was described. The method consists of four steps, going from investigation of the house to proposal for sustainable renovation, detailed planning and commissioning after renovation. It could be used by teams of consultants...... of the building envelope and the electricity required to run the system. Positive impact on the indoor environment can be expected. Thermal comfort will be improved by insulation and air-tightness measures that will increase surface temperatures and reduce draught from e.g. badly insulated windows. A ventilation...

  1. Low-cost multi-stage filtration enhanced by coagulation-flocculation in upflow gravel filtration

    Directory of Open Access Journals (Sweden)

    L. D. Sánchez

    2012-12-01

    Full Text Available This paper assesses the operational and design aspects of coagulation and flocculation in upflow gravel filters (CF-UGF in a multi-stage filtration (MSF plant. This study shows that CF-UGF units improve the performance of MSF considerably, when the system operates with turbidity above 30 NTU. It strongly reduces the load of particulate material before the water enters in the slow sand filters (SSF and therewith avoids short filter runs and prevents early interruption in SSF operations. The removal efficiency of turbidity in the CF-UGF with coagulant was between 85 and 96%, whereas the average efficiency without coagulant dosing was 46% (range: 21–76%. Operating with coagulant also improves the removal efficiency for total coliforms, E-coli and HPC. No reduction was observed in the microbial activity of the SSF, no obstruction of the SSF bed was demonstrated and SSF runs were maintained between 50 and 70 days for a maximum head loss of 0.70 m. The most important advantage is the flexibility of the system to operate with and without coagulant according to the influent turbidity. It was only necessary for 20% of the time to operate with the coagulant. The CF-UGF unit represented 7% of total construction costs and the O&M cost for the use of coagulant represented only 0.3%.

  2. 77 FR 55832 - Ambient Air Monitoring Reference and Equivalent Methods: Designation of a New Equivalent Method

    Science.gov (United States)

    2012-09-11

    ... automated monitoring method utilizing a measurement principle based on sample collection by filtration and... 58. Questions concerning the commercial availability or technical aspects of the method should be...

  3. Neutron flux filtration using Kalman filter

    International Nuclear Information System (INIS)

    Urcikan, Marian

    2005-01-01

    In the course of the WWER-440 start-up procedure the time dependent reactivity is determined from the measured ionization chamber signal by inverse kinetic method. Due to the random nature of the fission process and random nature the detection process the measured ionization chamber signal contains certain noise content. To minimize the unwonted noise on measured reactivity one of the possibility method is utilization Kalman filter, based on a stochastic model of reactor system (Author)

  4. Measurement of glomerular filtration rate in children using technetium-99m diethylenetriamine penta-acetic acid

    International Nuclear Information System (INIS)

    Aaronson, I.A.; Mann, M.D.

    1985-01-01

    During the past 5 years, we have measured the glomerular filtration rate (GFR) by the slope-clearance method using technetium-99m diethylenetriamine penta-acetic acid technetium-99m-DTPA in 130 infants and children. The results in 22 children have been compared with inulin clearance, and a very good correlation between the two methods of measurement of GFR was demonstrated (r = 0,9616; P less than 0,0001). This study provides further evidence that technetium-99m-DTPA is a satisfactory agent for the clinical measurement of GFR in children

  5. Multifunctional nanocomposites of carbon nanotubes and nanoparticles formed via vacuum filtration

    Science.gov (United States)

    Hersam, Mark C; Ostojic, Gordana; Liang, Yu Teng

    2013-10-22

    In one aspect, the present invention provides a method of forming a film of nanocomposites of carbon nanotubes (CNTs) and platinum (Pt) nanoparticles. In one embodiment, the method includes the steps of (a) providing a first solution that contains a plurality of CNTs, (b) providing a second solution that contains a plurality of Pt nanoparticles, (c) combining the first solution and the second solution to form a third solution, and (d) filtering the third solution through a nanoporous membrane using vacuum filtration to obtain a film of nanocomposites of CNTs and Pt nanoparticles.

  6. The Use of Innovative Ceramic-Carbon Bonded Filters Used for Filtration of Liquid Alloys and Evaluation of the Filtration Efficiency

    Directory of Open Access Journals (Sweden)

    Karwiński A.

    2014-08-01

    Full Text Available Extremely intense development of civilization requires from foundry casting technologies very high quality and not expensive castings. In the foundries, there are many treatments that allow increasing of the final properties of produced castings such as refining, modification, heat treatment, etc. One of the methods of increasing the quality of the casting by removing inclusions from the liquid alloy is filtration. The use of ceramic-carbon foam filters in filtration process is still analysed phenomenon that allows improving the final properties of castings. A modern method of research, testing and synthesis of innovative chemical compositions allows improving the properties of such filters. In the paper the evaluation of application properties of developed ceramic-carbon bonded foam filters is presented. The quality of the foam filters is evaluated by Computer Tomography and foundry trials in pouring of liquid metal in test molds. Additionally computer simulations were made to visualize the flow characteristics in the foam filter. The analysed filters are the result of the research work of Foundry Research Institute and the Institute of Ceramics and Building Materials, Refractory Materials Department in Gliwice.

  7. Measurement of glomerular filtration rate in the conscious rat.

    Science.gov (United States)

    Pestel, Sabine; Krzykalla, Volker; Weckesser, Gerhard

    2007-01-01

    Glomerular filtration rate (GFR) is an important parameter for studying drug-induced impairments on renal function in rats. The GFR is calculated from the concentration of creatinine and blood urea nitrogen (BUN) in serum and in urine, respectively. Following current protocols serum and urine samples must be taken from the same animal. Thus, in order to determine time-dependent effects it is necessary to use for each time point one separated group of animals. We developed a statistical test which allows analyzing the GFR from two different groups of animals: one used for repeated serum and the other one used for repeated urine analysis. Serum and urine samples were taken from two different sets of rats which were otherwise treated identically, i.e. drug doses, routes of administration (per os or per inhalation) and tap water loading. For each dose group GFR mean, standard deviation and statistical analysis to identify differences between the dose groups were determined. After determination of the optimal time points for measurements, the effect on GFR of the three reference compounds, furosemide, hydrochlorothiazide and formoterol, was calculated. The results showed that the diuretic drugs furosemide and hydrochlorothiazide decreased the GFR and the antidiuretic drug formoterol increased the GFR, as counter regulation on urine loss or urine retention, respectively. A mathematical model and the corresponding algorithm were developed, which can be used to calculate the GFR, and to test for differences between groups from two separated sets of rats, one used for urine, and the other one for serum analysis. This new method has the potential to reduce the number of animals needed and to improve the quality of data generated from various groups of animals in renal function studies.

  8. Assessment of endophytic fungi cultural filtrate on soybean seed ...

    African Journals Online (AJOL)

    Soybean seeds have high amount of isoflavones but its germination is often confronted with a variety of environmental problems resulting in low germination rate and growth. To overcome this in eco-friendly manner, we investigated the influence of cultural filtrate (CF) of gibberellins-producing endophytic fungi on soybean ...

  9. Alternative filtration testing program: Pre-evaluation of test results

    International Nuclear Information System (INIS)

    Georgeton, G.K.; Poirier, M.R.

    1990-01-01

    Based on results of testing eight solids removal technologies and one pretreatment option, it is recommended that a centrifugal ultrafilter and polymeric ultrafilter undergo further testing as possible alternatives to the Norton Ceramic filters. Deep bed filtration should be considered as a third alternative, if a backwashable cartridge filter is shown to be inefficient in separate testing

  10. Iron behavior in the ozonation and filtration of groundwater

    Energy Technology Data Exchange (ETDEWEB)

    Sallanko, J.; Lakso, E.; Ropelinen, J. [University of Oulu, Oulu (Finland)

    2006-08-15

    In Finnish groundwater, the main substances that require treatment are iron and manganese. In addition to this, groundwaters are soft and acidic. Iron removal is usually relatively effective by oxidizing dissolved iron into an insoluble form, either by aeration or chemical oxidation and removing the formed precipitate by sand filtration. Sometimes, if the untreated water contains high amounts of organic matter, problems may arise for iron removal. In Finland, it is quite common that groundwater contains high levels of both iron and natural organic matter, mainly as humic substances. The groundwater of the Kukkala intake plant in Liminka has been found to be problematic, due to its high level of natural organic matter. This research studied the removal of iron from this water by means of oxidation with ozone and filtration. While the oxidation of iron by ozone was rapid, the precipitate particles formed were small, and thus could not be removed by sand and anthracite filtration, and the iron residue in the treated water was more than 2 mg L{sup -1}. And while the filtration was able to remove iron well without the feed of ozone, the iron residue in the treated water was only 0.30 mg L{sup -1}. In this case, iron was led to the filter in a bivalent dissolved form. So, the result of iron removal was the best when the sand/anthracite filter functioned largely as an adsorption filter.

  11. The impact of metallic filter media on HEPA filtration

    International Nuclear Information System (INIS)

    Chadwick, Chris; Kaufman, Seth

    2006-01-01

    Traditional HEPA filter systems have limitations that often prevent them from solving many of the filtration problems in the nuclear industry; particularly in applications where long service or storage life, high levels of radioactivity, dangerous decomposition products, chemical aggression, organic solvents, elevated operating temperatures, fire resistance and resistance to moisture are issues. This paper addresses several of these matters of concern by considering the use of metallic filter media to solve HEPA filtration problems ranging from the long term storage of transuranic waste at the WIPP site, spent and damaged fuel assemblies, in glove box ventilation and tank venting to the venting of fumes at elevated temperatures from incinerators, vitrification processes and conversion and sintering furnaces as well as downstream of iodine absorbers in gas cooled reactors in the UK. The paper reviews the basic technology, development, performance characteristics and filtration efficiency, flow versus differential pressure, cleanability and costs of sintered metal fiber in comparison with traditional resin bonded glass fiber filter media and sintered metal powder filter media. Examples of typical filter element and system configurations and applications will be presented The paper will also address the economic case for installing self cleaning pre-filtration, using metallic media, to recover the small volumes of dust that would otherwise blind large volumes of final disposable HEPA filters, thus presenting a route to reduce ultimate disposal volumes and secondary waste streams. (authors)

  12. Evaluation of condensate filtration technologies in fossil plants

    Energy Technology Data Exchange (ETDEWEB)

    D' Angelo, Philip J. [JoDan Technologies Ltd., Glen Mills, PA (United States)

    2009-09-15

    Long-term protection of electric power generating station boilers depends upon the quality of their feedwater chemistry with respect to the transport and deposition of corrosion products to the boilers from various corrosion sources in the plant's condensate and feedwater cycle. It is in the utility's best interests to expand their programs to include ways to reduce the transport of corrosion products, especially those that occur during plant start-ups. Condensate filtration is a strategy employed by some utilities with demonstrable results in minimizing corrosion product transport and achieving a return on their investment. This paper provides a comparative review of available condensate filtration technologies as well as performance data from fossil plants with the new large diameter high flow filtration systems. Additionally, the paper identifies critical parameters to consider before installation as well as the necessity for agreement between utilities and suppliers on common filtration terminology definitions, to insure an ''apple-to-apple'' basis when comparing a system or technology from more than one supplier. (orig.)

  13. Removal of Brettanomyces bruxellensis from red wine using membrane filtration

    Science.gov (United States)

    While sulfites help limit growth of the spoilage yeast, Brettanomyces, SO2 has been reported to decrease cell size, thereby potentially decreasing the porosities of filtration membranes required for removal. B. bruxellensis strains B1b and F3 were inoculated into red wines and after 12 days, half th...

  14. Polymer aids for settling and filtration of oil sands tailings

    Energy Technology Data Exchange (ETDEWEB)

    Wang, X. [Alberta Univ., Edmonton, AB (Canada). Dept. of Chemical and Materials Engineering; Energy Resources Conservation Board, Calgary, AB (Canada). Oil Sands Section; Xu, Z.; Masliyah, J.H. [Alberta Univ., Edmonton, AB (Canada). Dept. of Chemical and Materials Engineering

    2008-07-01

    Oil sand tailings are segregated into coarse and fine tailings. High volumes of toxic fluids and tailings are created in the process. Tailings ponds are an environmental risk with high operating and maintenance costs. Current commercial technologies uses chemical additions to create recycled water and composite tailings (CT). Researchers are now investigating centrifuged and dry mature fine tailings (MFT). Filtration processes with flocculants are used to separate the tailings into warm recycle water and dried cakes that can be used in reclamation processes. Studies are being conducted to find a polymer than can effectively flocculate and filter whole oil sands tailings. The filtration procedure uses pressure to produce released water. Polymers include magnafloc and Al-PAM polymer concentrations are used in slurry masses. Tests have been conducted to determine the settling rates of the polymers. The tests showed that Al-PAM filtered the tailings effectively. Paraffinic froth treatment tests have also been conducted to determine settling rates. A cake produced with froth treatment tailings of Al-PAM 400 ppm had a water content 42.5 wt per cent. The tests showed that while Magnafloc 1011 is a good settling aid, but a poor filtration addition. Al-PAM aided in both the flocculation and filtration processes. Higher Al-PAM dosages are needed for froth treatment tailings processes. It was concluded that dry cakes are produced with the addition of Al-PAM. tabs., figs.

  15. Radioactive slurry waste treatment (2) - surfactants dose effects on filtration

    International Nuclear Information System (INIS)

    Jung, K. H.; Park, S. K.; Jung, W. S.; Baek, S. T.; Jung, K. J.

    1999-01-01

    The influence of anionic flocculants on the dewatering of radioactive slurries has been investigated in a laboratory-scale vacuum filtration unit. Simultaneously the influence of certain surfactants has also been investigated. Test results show that the flocculated filter cake generally contains higher residual water than the unflocculated cake. The non-ionic surfactant was effective in reducing the moisture content of the cake

  16. Initial testing of electrospun nanofibre filters in water filtration ...

    African Journals Online (AJOL)

    The aim of this study was to evaluate the use of nanofibre microfiltration membranes, spun by an innovative electrospinning technique, in water filtration applications. As such, this study bridges the gap between developments in electrospinning techniques for the production of flat-sheet membranes and the application of ...

  17. Cross-flow micro-filtration using ceramic membranes

    International Nuclear Information System (INIS)

    Thern, Gerardo G.; Marajofsky, Adolfo; Rossi, Federico; La Gamma, Ana M.; Chocron, Mauricio

    2004-01-01

    Pressurized Heavy Water Reactors have a system devoted to the purification and upgrading of the collected heavy water leaks. The purification train is fed with different degradation ratios (D 2 O/H 2 O), activities and impurities. The water is distilled in a packed bed column filled with a mesh type packing. With the purpose of minimizing the column stack corrosion, the water is pre-treated in a train consisting on an activated charcoal bed-strong cationic-anionic resin and a final polishing anionic bed resin. Traces of oils are retained by the charcoal bed but some of them pass through and could be responsible for the resins fouling. The process of micro filtration using ceramic materials is particularly applied to the treatment of waters with oil micro droplets. We describe the development stages of single and double layer filtration ceramic tubes, their characterization and the adaptation to test equipment. The efficiency was evaluated by means of tangential ('cross-flow') filtration of aqueous solutions containing dodecane at the micrograms per ml concentration level. This compound simulates the properties of a typical oil contaminant. A 100-fold reduction in the amount of dodecane in water was observed after the filtration treatment. (author)

  18. Reduced glomerular filtration rate as a predictor of coronary artery ...

    African Journals Online (AJOL)

    Tarek A. Ghonemy

    2016-07-09

    Jul 9, 2016 ... Internal Medicine Department, Nephrology Unit, Zagazig University ... glomerular filtration rate (eGFR) and risk of coronary artery disease ... ing of eGFR may have a pivotal role in early detection and management of CAD in those types of ..... position statement from kidney disease improving global out-.

  19. Alternative filtration testing program: Pre-evaluation of test results

    Energy Technology Data Exchange (ETDEWEB)

    Georgeton, G.K.; Poirier, M.R.

    1990-09-28

    Based on results of testing eight solids removal technologies and one pretreatment option, it is recommended that a centrifugal ultrafilter and polymeric ultrafilter undergo further testing as possible alternatives to the Norton Ceramic filters. Deep bed filtration should be considered as a third alternative, if a backwashable cartridge filter is shown to be inefficient in separate testing.

  20. Experimental and Numerical Study of Ceramic Foam Filtration

    Science.gov (United States)

    Laé, E.; Duval, H.; Rivière, C.; Le Brun, P.; Guillot, J.-B.

    Ceramic foam filtration is widely used to enable removal of non metallic inclusions from liquid aluminium. Its performances have been largely studied in the literature and some discrepancies remain amongst the published results. Consequently, a research program was deployed to evaluate the performances of a range of ceramic foam filters used under various conditions and to understand the inclusions capture mechanisms.

  1. Batch cooling crystallization and pressure filtration of sulphathiazole

    DEFF Research Database (Denmark)

    Häkkinen, Antti; Pöllänen, Kati; Karjalainen, Milja

    2005-01-01

    Currently there is a great interest in new process analytical approaches to increase the process understanding of pharmaceutical unit operations. In the present study, the influence of the solvent composition on the material properties and, further, on the filtration characteristics, of different...

  2. Separation of nanoparticles: Filtration and scavenging from waste incineration plants.

    Science.gov (United States)

    Förster, Henning; Thajudeen, Thaseem; Funk, Christine; Peukert, Wolfgang

    2016-06-01

    Increased amounts of nanoparticles are applied in products of everyday life and despite material recycling efforts, at the end of their life cycle they are fed into waste incineration plants. This raises the question on the fate of nanoparticles during incineration. In terms of environmental impact the key question is how well airborne nanoparticles are removed by separation processes on their way to the bag house filters and by the existing filtration process based on pulse-jet cleanable fibrous filter media. Therefore, we investigate the scavenging and the filtration of metal nanoparticles under typical conditions in waste incineration plants. The scavenging process is investigated by a population balance model while the nanoparticle filtration experiments are realized in a filter test rig. The results show that depending on the particle sizes, in some cases nearly 80% of the nanoparticles are scavenged by fly ash particles before they reach the bag house filter. For the filtration step dust cakes with a pressure drop of 500Pa or higher are found to be very effective in preventing nanoparticles from penetrating through the filter. Thus, regeneration of the filter must be undertaken with care in order to guarantee highly efficient collection of particles even in the lower nanometre size regime. Copyright © 2016 Elsevier Ltd. All rights reserved.

  3. Successful treatment of homozygous familial hypercholesterolemia using cascade filtration plasmapheresis.

    Science.gov (United States)

    Kardaş, Fatih; Cetin, Aysun; Solmaz, Musa; Büyükoğlan, Rüksan; Kaynar, Leylagül; Kendirci, Mustafa; Eser, Bülent; Unal, Ali

    2012-12-01

    The aim of this study was to report the efficacy of low-density lipoprotein cholesterol (LDL-C) apheresisusing a cascade filtration system in pediatric patients with homozygous familial hypercholesterolemia (FH), and toclarify the associated adverse effects and difficulties. LDL-C apheresis using a cascade filtration system was performed in 3 pediatric patientswith homozygous FH; in total, 120 apheresis sessions were performed. Cascade filtration therapy significantly reduced the mean LDL-C values from 418 ± 62 mg/dL to 145 ± 43 mg/dL (p= 0.011). We observed an acute mean reduction in the plasma level of total cholesterol (57.9%), LDL-C (70.8%),and high-density lipoprotein cholesterol (HDL-C) (40.7%). Treatments were well tolerated. The most frequent clinicaladverse effects were hypotension in 3 sessions (2.5%), chills (1.7%) in 2 sessions, and nausea/vomiting in 3 sessions(2.5%). Our experience using the cascade filtration system with 3 patients included good clinical outcomes andlaboratory findings, safe usage, and minor adverse effects and technical problems. None declared.

  4. The Effect of Cyanobacterial Biomass Enrichment by Centrifugation and GF/C Filtration on Subsequent Microcystin Measurement

    Directory of Open Access Journals (Sweden)

    Shelley Rogers

    2015-03-01

    Full Text Available Microcystins are cyclic peptides produced by multiple cyanobacterial genera. After accumulation in the liver of animals they inhibit eukaryotic serine/threonine protein phosphatases, causing liver disease or death. Accurate detection/quantification of microcystins is essential to ensure safe water resources and to enable research on this toxin. Previous methodological comparisons have focused on detection and extraction techniques, but have not investigated the commonly used biomass enrichment steps. These enrichment steps could modulate toxin production as recent studies have demonstrated that high cyanobacterial cell densities cause increased microcystin levels. In this study, three microcystin-producing strains were processed using no cell enrichment steps (by direct freezing at three temperatures and with biomass enrichment (by centrifugation or GF/C filtration. After extraction, microcystins were analyzed using liquid chromatography-tandem mass spectrometry. All processing methods tested, except GF/C filtration, resulted in comparable microcystin quotas for all strains. The low yields observed for the filtration samples were caused by adsorption of arginine-containing microcystins to the GF/C filters. Whilst biomass enrichment did not affect microcystin metabolism over the time-frame of normal sample processing, problems associated with GF/C filtration were identified. The most widely applicable processing method was direct freezing of samples as it could be utilized in both field and laboratory environments.

  5. Comparison of Dilution, Filtration, and Microwave Digestion Sample Pretreatments in Elemental Profiling of Wine by ICP-MS.

    Science.gov (United States)

    Godshaw, Joshua; Hopfer, Helene; Nelson, Jenny; Ebeler, Susan E

    2017-09-25

    Wine elemental composition varies by cultivar, geographic origin, viticultural and enological practices, and is often used for authenticity validation. Elemental analysis of wine by Inductively Coupled Plasma Mass Spectrometry (ICP-MS) is challenging due to the potential for non-spectral interferences and plasma instability arising from organic matrix components. Sample preparation mitigates these interferences, however, conflicting recommendations of best practices in ICP-MS analysis of wine have been reported. This study compared direct dilution, microwave-assisted acid digestion, and two filtration sample pretreatments, acidification prior to filtration and filtration followed by acidification, in elemental profiling of one white and three red table wines by ICP-MS. Of 43 monitored isotopes, 37 varied by sample preparation method, with significantly higher results of 17 isotopes in the microwave-digested samples. Both filtration treatments resulted in lower results for 11 isotopes compared to the other methods. Finally, isotope dilution determination of copper based on natural abundances and the 63 Cu: 65 Cu instrument response ratio agreed with external calibration and confirmed a significant sample preparation effect. Overall, microwave digestion did not compare favorably, and direct dilution was found to provide the best compromise between ease of use and result accuracy and precision, although all preparation strategies were able to differentiate the wines.

  6. Estimating glomerular filtration rate in a population-based study

    Directory of Open Access Journals (Sweden)

    Anoop Shankar

    2010-07-01

    Full Text Available Anoop Shankar1, Kristine E Lee2, Barbara EK Klein2, Paul Muntner3, Peter C Brazy4, Karen J Cruickshanks2,5, F Javier Nieto5, Lorraine G Danforth2, Carla R Schubert2,5, Michael Y Tsai6, Ronald Klein21Department of Community Medicine, West Virginia University School of Medicine, Morgantown, WV, USA; 2Department of Ophthalmology and Visual Sciences, 4Department of Medicine, 5Department of Population Health Sciences, University of Wisconsin, School of Medicine and Public Health, Madison, WI, USA; 3Department of Community Medicine, Mount Sinai School of Medicine, NY, USA; 6Department of Laboratory Medicine and Pathology, University of Minnesota, Minneapolis, MN, USABackground: Glomerular filtration rate (GFR-estimating equations are used to determine the prevalence of chronic kidney disease (CKD in population-based studies. However, it has been suggested that since the commonly used GFR equations were originally developed from samples of patients with CKD, they underestimate GFR in healthy populations. Few studies have made side-by-side comparisons of the effect of various estimating equations on the prevalence estimates of CKD in a general population sample.Patients and methods: We examined a population-based sample comprising adults from Wisconsin (age, 43–86 years; 56% women. We compared the prevalence of CKD, defined as a GFR of <60 mL/min per 1.73 m2 estimated from serum creatinine, by applying various commonly used equations including the modification of diet in renal disease (MDRD equation, Cockcroft–Gault (CG equation, and the Mayo equation. We compared the performance of these equations against the CKD definition of cystatin C >1.23 mg/L.Results: We found that the prevalence of CKD varied widely among different GFR equations. Although the prevalence of CKD was 17.2% with the MDRD equation and 16.5% with the CG equation, it was only 4.8% with the Mayo equation. Only 24% of those identified to have GFR in the range of 50–59 mL/min per 1

  7. Filtration effectiveness of HVAC systems at near-roadway schools.

    Science.gov (United States)

    McCarthy, M C; Ludwig, J F; Brown, S G; Vaughn, D L; Roberts, P T

    2013-06-01

    Concern for the exposure of children attending schools located near busy roadways to toxic, traffic-related air pollutants has raised questions regarding the environmental benefits of advanced heating, ventilation, and air-conditioning (HVAC) filtration systems for near-road pollution. Levels of black carbon and gaseous pollutants were measured at three indoor classroom sites and at seven outdoor monitoring sites at Las Vegas schools. Initial HVAC filtration systems effected a 31-66% reduction in black carbon particle concentrations inside three schools compared with ambient air concentrations. After improved filtration systems were installed, black carbon particle concentrations were reduced by 74-97% inside three classrooms relative to ambient air concentrations. Average black carbon particle concentrations inside the schools with improved filtration systems were lower than typical ambient Las Vegas concentrations by 49-96%. Gaseous pollutants were higher indoors than outdoors. The higher indoor concentrations most likely originated at least partially from indoor sources, which were not targeted as part of this intervention. Recent literature has demonstrated adverse health effects in subjects exposed to ambient air near major roadways. Current smart growth planning and infill development often require that buildings such as schools are built near major roadways. Improving the filtration systems of a school's HVAC system was shown to decrease children's exposure to near-roadway diesel particulate matter. However, reducing exposure to the gas-phase air toxics, which primarily originated from indoor sources, may require multiple filter passes on recirculated air. © 2012 John Wiley & Sons A/S. Published by Blackwell Publishing Ltd.

  8. Impacts of extreme flooding on riverbank filtration water quality.

    Science.gov (United States)

    Ascott, M J; Lapworth, D J; Gooddy, D C; Sage, R C; Karapanos, I

    2016-06-01

    Riverbank filtration schemes form a significant component of public water treatment processes on a global level. Understanding the resilience and water quality recovery of these systems following severe flooding is critical for effective water resources management under potential future climate change. This paper assesses the impact of floodplain inundation on the water quality of a shallow aquifer riverbank filtration system and how water quality recovers following an extreme (1 in 17 year, duration >70 days, 7 day inundation) flood event. During the inundation event, riverbank filtrate water quality is dominated by rapid direct recharge and floodwater infiltration (high fraction of surface water, dissolved organic carbon (DOC) >140% baseline values, >1 log increase in micro-organic contaminants, microbial detects and turbidity, low specific electrical conductivity (SEC) 400% baseline). A rapid recovery is observed in water quality with most floodwater impacts only observed for 2-3 weeks after the flooding event and a return to normal groundwater conditions within 6 weeks (lower fraction of surface water, higher SEC, lower DOC, organic and microbial detects, DO). Recovery rates are constrained by the hydrogeological site setting, the abstraction regime and the water quality trends at site boundary conditions. In this case, increased abstraction rates and a high transmissivity aquifer facilitate rapid water quality recoveries, with longer term trends controlled by background river and groundwater qualities. Temporary reductions in abstraction rates appear to slow water quality recoveries. Flexible operating regimes such as the one implemented at this study site are likely to be required if shallow aquifer riverbank filtration systems are to be resilient to future inundation events. Development of a conceptual understanding of hydrochemical boundaries and site hydrogeology through monitoring is required to assess the suitability of a prospective riverbank filtration

  9. Effect of hypothermic pulmonary artery flushing on capillary filtration coefficient.

    Science.gov (United States)

    Andrade, R S; Wangensteen, O D; Jo, J K; Tsai, M Y; Bolman, R M

    2000-07-27

    We previously demonstrated that surfactant dilution and inhibition occur immediately after pulmonary artery flushing with hypothermic modified Euro-Collins solution. Consequently, we speculated that increased capillary permeability contributed to these surfactant changes. To test this hypothesis, we evaluated the effects of hypothermic pulmonary artery flushing on the pulmonary capillary filtration coefficient (Kfc), and additionally performed a biochemical analysis of surfactant. We used a murine isolated, perfused lung model to measure the pulmonary capillary filtration coefficient and hemodynamic parameters, to determine the wet to dry weight ratio, and to evaluate surfactant by biochemical analysis of lung lavage fluid. We defined three study groups. In group I (controls), we harvested lungs without hypothermic pulmonary artery flushing, and measured Kfc immediately. In group II (in situ flush), we harvested lungs after hypothermic pulmonary artery flushing with modified Euro-Collins solution, and then measured Kfc. Experiments in groups I and II were designed to evaluate persistent changes in Kfc after pulmonary artery flushing. In group III (ex vivo flush), we flushed lungs ex vivo to evaluate transient changes in Kfc during hypothermic pulmonary artery flushing. Groups I and II did not differ significantly in capillary filtration coefficient and hemodynamics. Group II showed significant alterations on biochemical surfactant analysis and a significant increase in wet-to-dry weight ratio, when compared with group I. In group III, we observed a significant transient increase in capillary filtration coefficient during pulmonary artery flushing. Hypothermic pulmonary artery flushing transiently increases the capillary filtration coefficient, leads to an increase in the wet to dry weight ratio, and induces biochemical surfactant changes. These findings could be explained by the effects of hypothermic modified Euro-Collins solution on pulmonary capillary

  10. Filtration behavior of silver nanoparticle agglomerates and effects of the agglomerate model in data analysis

    International Nuclear Information System (INIS)

    Buha, Jelena; Fissan, Heinz; Wang, Jing

    2013-01-01

    In many data evaluation procedures for particle measuring devices and in filtration models, spherical particles are assumed. However, significant fractions of aerosol particles are agglomerates of small primary spheres. The morphology of particles in filtration processes may not be known a priori and if the filtration data are processed with wrong assumption, errors can be induced. In this work, we have quantified such errors for the case of open-structured agglomerates. Filtration efficiency tests with polydisperse silver nanoparticle agglomerates and their sintered spheres were performed. After the sintering process, particles with a compact structure with the shape close to a sphere are obtained, which are referred to as sintered spheres in the present study. The testing method involved generation of particulate forms, passing the particles through the testing section, and measurement of the particle number concentrations and size distributions before and after the filter. Measurements of the aerosols upstream and downstream of the filter were conducted using scanning mobility particle sizers (SMPS, TSI Inc.), which covered the rage from 10 to 480 nm. Particles were additionally characterized from the electron microscopic images and the average primary particle size was determined to be 16.8 nm. The number-size distribution curves were obtained and used for penetration calculation. The penetration was dependent on the particle size and morphology. Silver-sintered spheres were captured with a lower efficiency than agglomerates with the same mobility diameter because of the stronger interception effect for agglomerates. Data analysis of the number-size distribution for agglomerates was processed based on sphere assumption and using the model for open-structured agglomerates developed by Lall and Friedlander. The efficiencies based on total concentrations of number, surface and volume were affected when the agglomerate model was used. The effect was weakest for the

  11. Stochastic modeling of filtrate alkalinity in water filtration devices: Transport through micro/nano porous clay based ceramic materials

    Science.gov (United States)

    Clay and plant materials such as wood are the raw materials used in manufacture of ceramic water filtration devices around the world. A step by step manufacturing procedure which includes initial mixing, molding and sintering is used. The manufactured ceramic filters have numerous pores which help i...

  12. Analytical filtration model for nonlinear viscoplastic oil in the theory of oil production stimulation and heating of oil reservoir in a dual-well system

    Science.gov (United States)

    Ivanovich Astafev, Vladimir; Igorevich Gubanov, Sergey; Alexandrovna Olkhovskaya, Valeria; Mikhailovna Sylantyeva, Anastasia; Mikhailovich Zinovyev, Alexey

    2018-02-01

    Production of high-viscosity oil and design of field development systems for such oil is one of the most promising directions in the development of world oil industry. The ability of high-viscosity oil to show in filtration process properties typical for non-Newtonian systems is proven by experimental studies. Nonlinear relationship between the pressure gradient and the rate of oil flow is due to interaction of high-molecular substances, in particular, asphaltenes and tars that form a plastic structure in it. The authors of this article have used the analytical model of stationary influx of nonlinear viscoplastic oil to the well bottom in order to provide rationale for the intensifying impact on a reservoir. They also have analyzed the method of periodic heating of productive reservoir by means of dual-wells. The high-temperature source is placed at the bottom of the vertical well, very close to the reservoir; at the same time the side well, located outside the zone of expected rock damage, is used for production. Suggested method of systemic treatment of reservoirs with dual wells can be useful for small fields of high-viscosity oil. The effect is based on the opportunity to control the structural and mechanical properties of high-viscosity oil and to increase depletion of reserves.

  13. MODEL REPRESENTATION OF THE SPRAY DRYING PROCESS OF THE DISTILLERY STILLAGE FILTRATE BASED ON NAVIERSTOKES EQUATIONS

    Directory of Open Access Journals (Sweden)

    A. A. Shevtsov

    2015-01-01

    Full Text Available Spray drying of solutions and suspensions is among the most common methods of producing a wide range of powdered products in chemical, food and pharmaceutical industries. For the drying of heat-sensitive materials, which is fully applicable to the distillery stillage filtrate continuous-flow type of contact of drying agent and the solution droplets is examined. Two-phase simulation method of computational hydrodynamics in a stationary state for studying the process of drying of the distillery stillage filtrate in the pilot spray dryer under the following assumptions was used. The components form an ideal mixture, the properties of which are calculated directly from the properties of the components and their proportions. The droplets were presented in spherical form. The density and specific heat of the solution and the coefficient of vapors diffusion in the gas phase remained unchanged. To solve the heat exchange equations between the drying agent and the drops by the finite volume method the software package ANSYS CFX was used. The bind between the two phases was established by Navier-Stokes equations. The continuous phase (droplets of the distillery stillage filtrate was described by the k-ε turbulence model. The results obtained showed that the interaction of "drop-wall" causes a significant change of velocity, temperature and humidity both of a drying agent and the product particles. The behavior of the particles by spraying, collision with walls and deposition of the finished product allowed to determine the dependence of physical parameters of the drying process, of the geometric dimensions of the dryer. Comparison of simulation results with experimental data showed satisfactory convergence of the results: for the temperature of the powder 10% its humidity of 12% and temperature of the spent drying agent at the outlet from the drier of 13%. The possibility of using the model in the spray dryers designing, and control of the drying process

  14. Radioimmunoassay kit formulation and its validation for serum progesterone using progesterone radiotracer purified by gel filtration

    International Nuclear Information System (INIS)

    Karir, T.; Pal, N.; Sivaprasad, N.

    2003-01-01

    Purification of the radioiodinated progesterone tyrosine methyl ester conjugate by gel filtration and the development, optimization and clinical validation of a direct radioimmunoassay (RIA) of progesterone using this radiotracer are described. High purity radiotracer is essential for the error free performance of any RIA. Progesterone 11α hemisuccinate was conjugated to tyrosine methyl ester (TME) by the mixed anhydride method and this conjugate was then radioiodinated by the chloramine-T method. Purification of the radioiodinated product was carried out by gel filtration. About 12 batches of the radiotracer were prepared and purified. The purification by gel filtration gave reproducible elution pattern and purity. The radiotracer thus purified was found to have consistent quality as compared to that of any other purification methods. Non-specific binding of the radiotracer was found to be 95% as checked by paper electrophoresis. The stability (retention of the immunoreactivity) of the radiotracer was two to three months. No appreciable changes in the assay characteristics were observed during this period. The assay involved 3 hours incubation of progesterone antibody with individual standards or sample and radiotracer at room temperature. The optimized assay was then validated for internal and external quality control parameters. A RIA kit was then formulated with this radiotracer for estimation of progesterone in serum. The assay kit consisted of lyophilized individual standards ranging from 0.25 to 50 ng/ml. The clinical performance of the developed kit was compared with that of a commercial ELISA kit and a correlation of 0.94 was observed. (author)

  15. Expanded uncertainty estimation methodology in determining the sandy soils filtration coefficient

    Science.gov (United States)

    Rusanova, A. D.; Malaja, L. D.; Ivanov, R. N.; Gruzin, A. V.; Shalaj, V. V.

    2018-04-01

    The combined standard uncertainty estimation methodology in determining the sandy soils filtration coefficient has been developed. The laboratory researches were carried out which resulted in filtration coefficient determination and combined uncertainty estimation obtaining.

  16. Characterization, Washing, Leaching, and Filtration of C-104 Sludge

    Energy Technology Data Exchange (ETDEWEB)

    KP Brooks; PR Bredt; GR Golcar; SA Hartley; LK Jagoda; KG Rappe; MW Urie

    2000-06-09

    Approximately 1,400 g of wet Hanford Tank C-104 Sludge was evaluated by Battelle for the high-level waste (HLW) pretreatment processes of ultrafiltration, dilute caustic washing, and elevated-temperature caustic leaching. The filterability of diluted C-104 sludge was measured with a 0.1-{micro}m sintered metal Mott filter using a 24-inch-long, single-element, crossflow filtration system (cells unit filter [CUF]). While the filtrate was being recirculated prior to washing and leaching, a 6.9 wt% solids slurry was evaluated with a matrix of seven 1-hour conditions of varying trans-membrane pressure (30 to 70 psid) and axial velocity (9 to 15 ft/s). The filtrate flux and backpulse efficiency were determined for each condition. The slurry was concentrated to 23 wt% solids, a second matrix of six 1-hour conditions was performed, and data analogous to that recorded in the first matrix were obtained. The low-solids-concentration matrix produced filtrate flux rates that ranged from 0.038 to 0.083 gpm/ft{sup 2}. The high-solids-concentration matrix produced filtrate flux rates that ranged from 0.0095 to 0.0172 gpm/ft{sup 2}. In both cases, the optimum filtrate flux was at the highest axial velocity (15 ft/s) and transmembrane pressure had little effect. Nearly all of the measured filtrate fluxes were more than an order of magnitude greater than the required plant flux for C-104 of 0.00126 gpm/ft{sup 2}. In both matrices, the filtrate flux appeared to be proportional to axial velocity, and the permeability appeared to be inversely proportional to the trans-membrane pressure. The first test condition was repeated as the last test condition for each matrix. In both cases, there was a significant decrease in filtrate flux, indicating some filter fouling during the test matrix that could not be removed by backpulsing alone, although the backpulse number and duration were not optimized. Following testing of these two matrices, the material was washed within the CUF by

  17. Static and dynamic filtrations of different clay, electrolytes, polymer systems; Filtrations statiques et dynamiques de differents systemes argile, electrolytes, polymere

    Energy Technology Data Exchange (ETDEWEB)

    Li, Y

    1996-04-16

    Filtration properties of model drilling fluids composed of water, clays, electrolytes and water soluble polymers have been studied in static and dynamic conditions on paper filters and rock slices. Filtration experiments combined with cake observations by cryo-S.E.M. and T.E.M., show the influence of the size shape of clay particles as well as their associating mode in suspension, on the texture of the cake, its permeability, and relaxation properties. These parameters depend on the nature of the electrolyte. The polymer reduces the cake permeability by enhancing the dispersion of the clay within the suspension, but mainly by plugging the porous network due its auto aggregation properties. The cake construction in dynamic conditions, is related to the state of aggregation of the initial suspension, its poly-dispersity, its sensitivity to shear rates, and also, to the permeability of the cake built at the beginning of the filtration. In all cases, the rate of thickening of the cake is slower and larger filtrate volumes are obtained compared to the static conditions. Shear rate has two effects: first, to dissociate the weak aggregates in suspension, second, to impose a size selection of the particles in the case of a poly-dispersed suspension. At high shear rates, a cake of constant thin thickness is quickly obtained. The thickness of this limiting cake depends on the fraction of small particles present in suspension, or that can be formed by dissociation of weak aggregates under shear rate. The permeability of this limiting cake formed in dynamic conditions is, as in static conditions, controlled by the size and the shape of the particles that form the cake or by the presence of a build loss reducer water soluble polymer. Filtrations carried out on Fontainebleau sandstones allow to visualize the internal cake and to precise the risks of formation damage by the drilling fluid. (author) 127 refs.

  18. The topological filtration of gamma-structures

    DEFF Research Database (Denmark)

    Li, Thomas; Reidys, Christian

    2013-01-01

    In this paper we study gamma-structures filtered by topological genus. gamma-structures are a class of RNA pseudoknot structures that plays a key role in the context of polynomial time folding of RNA pseudoknot structures. A gamma-structure is composed by specific building blocks, that have...... topological genus less than or equal to gamma, where composition means concatenation and nesting of such blocks. Our main results are the derivation of a new bivariate generating function for gamma-structures via symbolic methods, the singularity analysis of the solutions and a central limit theorem...... for the distribution of topological genus in gamma-structures of given length. In our derivation specific bivariate polynomials play a central role. Their coefficients count particular motifs of fixed topological genus and they are of relevance in the context of genus recursion and novel folding algorithms....

  19. Lecithins - promising oil spill cleaner?

    International Nuclear Information System (INIS)

    Anon.

    1993-01-01

    A new, non-polluting method of cleaning up oil spills at sea as well as on land has been developed by researchers at the Hebrew University of Jerusalem. Their technique is based on the use of lecithins, a byproduct of producing edible oils from plants. Lecithin molecules are hydrophyllic at one end and lipophilic at their tail ends. When they come into contact with water, they organize themselves into bilayers whose heads all face the water and whose tails are all directed towards each other. These bilayers form particles called liposomes that, when spread on water fouled by oil spills, change the properties of the oil thereby stopping the spreading and breaking it down into sticky droplets that continue to float on the surface and can be easily collected. The treatment is said to be effective in both fresh and salt water and is almost temperature and pH independent. Another beneficial effect is that the physical change generated by liposomes in the spilled oil improves the ability of oil-eating bacteria in the water to remove some of the spill by bioremediation

  20. Purification of inkjet ink from water using liquid phase, electric discharge polymerization and cellulosic membrane filtration.

    Science.gov (United States)

    Jordan, Alexander T; Hsieh, Jeffery S; Lee, Daniel T

    2013-01-01

    A method to separate inkjet ink from water was developed using a liquid phase, electric discharge process. The liquid phase, electric discharge process with filtration or sedimentation was shown to remove 97% of inkjet ink from solutions containing between 0.1-0.8 g/L and was consistent over a range of treatment conditions. Additionally, particle size analysis of treated allyl alcohol and treated propanol confirmed the electric discharge treatment has a polymerization mechanism, and small molecule analysis of treated methanol using gas chromatography and mass spectroscopy confirmed the mechanism was free radical initiated polymerization.

  1. Body composition analysis by DEXA by using dynamically changing samarium filtration

    DEFF Research Database (Denmark)

    Gotfredsen, Arne; Baeksgaard, L; Hilsted, J

    1997-01-01

    Dual-energy X-ray absorptiometry (DEXA) has a high accuracy for body composition analysis but is influenced by beam hardening and other error sources in the extremes of measurement. To compensate for beam hardening, the Norland XR-36 introduces a dynamically changing samarium filtration system......). Scans of six healthy volunteers covered with combinations of beef and lard (approximately 5-15 kg) showed a good agreement (r = 0.99) between reference and DEXA values of added soft tissue mass and fat percentage. We conclude that the DEXA method (and, in particular, the Norland XR-36 using dynamic...

  2. Glomerular Filtration Rate Estimation in Renal and Non-Renal Solid Organ Transplantation

    DEFF Research Database (Denmark)

    Hornum, Mads; Feldt-Rasmussen, Bo

    2017-01-01

    Following transplantation (TX) of both renal and non-renal organs, a large proportion of patients have renal dysfunction. There are multiple causes for this. Chronic nephrotoxicity and high doses of calcineurin inhibitors are important factors. Preoperative and perioperative factors like...... or estimates of renal function in these patients, in order to accurately and safely dose immunosuppressive medication and perform and adjust the treatment and prophylaxis of renal dysfunction. This is a short overview and discussion of relevant studies and possible caveats of estimated glomerular filtration...... rate methods for use in renal and non-renal TX....

  3. Formation of Liquid Products at the Filtration Combustion of Solid Fuels

    Directory of Open Access Journals (Sweden)

    E. A. Salgansky

    2016-01-01

    Full Text Available Yields of liquid and gaseous products of the filtration combustion of cellulose, wood, peat, coal, and rubber have been investigated. Experiments have shown that the gasification of solid fuels in the regime with superadiabatic heating yields liquid hydrocarbons with quantity and quality, which are close to those produced using other methods, for example, by pyrolysis. But in this case no additional energy supply is needed to carry out the gasification process. The low calorific combustible gas, which forms in this process, contains a substantial quantity of carbon monoxide and hydrogen, which are components of syngas.

  4. Numerical Solutions of Mechanical Turbulent Filtration Equation Used in Mechatronics and Micro Mechanic

    OpenAIRE

    Hassan Fathabadi

    2013-01-01

    In this study, several novel numerical solutions are presented to solve the turbulent filtration equation and its special case called “Non-Newtonian mechanical filtration equation”. The turbulent filtration equation in porous media is a very important equation which has many applications to solve the problems appearing especially in mechatronics, micro mechanic and fluid mechanic. Many applied mechanical problems can be solved using this equation. For example, non-Newtonian mechanical filtrat...

  5. Particulate Matter Filtration Design Considerations for Crewed Spacecraft Life Support Systems

    Science.gov (United States)

    Agui, Juan H.; Vijayakumar, R.; Perry, Jay L.

    2016-01-01

    Particulate matter filtration is a key component of crewed spacecraft cabin ventilation and life support system (LSS) architectures. The basic particulate matter filtration functional requirements as they relate to an exploration vehicle LSS architecture are presented. Particulate matter filtration concepts are reviewed and design considerations are discussed. A concept for a particulate matter filtration architecture suitable for exploration missions is presented. The conceptual architecture considers the results from developmental work and incorporates best practice design considerations.

  6. Public health protection through bank filtration - Kearney Nebraska case study

    Science.gov (United States)

    Esseks, E.; Bellamy, W.; Heinemann, T.; Stocker, K.

    2003-04-01

    The investigation of Kearney's bank filtration system provides further evidence of this technology's capability to assist in providing public health protection, as it relates to drinking water. The results of hydrogeologic and treatment studies demonstrate the capabilities of the Platte River aquifer materials, in this locale, to remove pathogens and their surrogates. Continual monitoring and evaluations will establish the system’s longevity and continued treatment efficacy. The City of Kearney is located in south central Nebraska. The City owns and operates a public water system that serves approximately 24,889 people. The water system includes 12 wells located on Killgore Island in the Platte River. In 1994, the Nebraska Department of Health and Human Services System (Department) determined that 3 wells in the wellfield serving the City of Kearney were ground water under the direct influence of surface water. This determination was based on results of microscopic particulate analysis (MPA). The City of Kearney undertook the natural bank filtration study to determine whether natural bank filtration was occurring at the site and if the filtration was sufficient to meet pathogen treatment requirements designed to protect public health. A preliminary study was undertaken from June through October 1995. This coincided with the City’s peak pumping time, which may be the time when the influence of the River is greatest on the wellfield wells. Hydrogeologic studies assisted in selecting wells that were at highest risk based on shortest travel times and greatest differential head. Data collected included particle counts, MPAs, turbidity, coliform, centrifugate pellet evaluation (CPE) volumes, pH, conductivity, and temperature. Following analysis of data collected during the preliminary 18-week study the Department granted conditional approval of 2-log credit for removal of Giardia lamblia and 1-log credit for removal of viruses through bank filtration, pending the

  7. Correlation of the glomerular filtration rate by the Gates scintigraphy method and by the creatinine purification in urine of 24 hours; Correlacion de la tasa de filtracion glomerular por el metodo gamagrafico de Gates y por la depuracion de creatinina en orina de 24 horas

    Energy Technology Data Exchange (ETDEWEB)

    Gomez A, E

    2003-07-01

    The kidney is an important organ that makes that exist equilibrium inside the organism. In it' s multiple functions, one that interests us to know is the glomerular filtration rate (GFR). To know this, exist laboratory and scintigraphy studies like the scintigraphy with technique of Gates and the creatinine purification in urine of 24 hours. The files of 44 patients were studied, which were clinically candidates to kidney donors healthy (25 women and 19 men) with ages that varied from the 18 years to the 54 years ( 35.1 years), with a weight of 43 kilograms to 94 kilograms (68.95 Kg) and with a corporal surface of 1.29 to 2.08 m{sup 2} (1.70 m{sup 2}). These patients underwent study protocols with creatinine purification and with renal scintigraphy. The glomerular filtration rate obtained by creatinine purification varied from 51.9 ml/min. to 156 ml/min. and the GFR obtained by scintigraphy varied from 3.6 ml/min. to 155.2 ml/min. Once obtained the gathering of data the test of Student was applied to compare the averages of both distributions and the analysis of lineal regression to determine the coefficients of correlation of the complete group. (Author)

  8. Facilitating community water supply treatment : from transferring filtration technology to multi-stakeholder learning

    NARCIS (Netherlands)

    Visscher, J.T.

    2006-01-01

    For more than a quarter of a century, IRC has been supporting the development of Slow Sand Filtration (SSF) and more recently, together with CINARA, the pioneering of Multi-Stage Filtration (MSF) - a combination of Gravel Filtration and SSF that has been shown to have great potential as an effective

  9. 77 FR 38857 - Design, Inspection, and Testing Criteria for Air Filtration and Adsorption Units of Normal...

    Science.gov (United States)

    2012-06-29

    ... Filtration and Adsorption Units of Normal Atmosphere Cleanup Systems in Light-Water- Cooled Nuclear Power... Criteria for Air Filtration and Adsorption Units of Normal Atmosphere Cleanup Systems in Light-Water-Cooled... draft regulatory guide (DG), DG-1280, ``Design, Inspection, and Testing Criteria for Air Filtration and...

  10. 40 CFR 141.717 - Pre-filtration treatment toolbox components.

    Science.gov (United States)

    2010-07-01

    ... surface water or GWUDI source. (c) Bank filtration. Systems receive Cryptosporidium treatment credit for... paragraph. Systems using bank filtration when they begin source water monitoring under § 141.701(a) must... 40 Protection of Environment 22 2010-07-01 2010-07-01 false Pre-filtration treatment toolbox...

  11. 76 FR 82323 - Design, Inspection, and Testing Criteria for Air Filtration and Adsorption Units

    Science.gov (United States)

    2011-12-30

    ... Filtration and Adsorption Units AGENCY: Nuclear Regulatory Commission. ACTION: Draft regulatory guide... for Air Filtration and Adsorption Units of Postaccident Engineered-Safety-Feature Atmosphere Cleanup... testing of air filtration and iodine adsorption units of engineered-safety-feature (ESF) atmosphere...

  12. Analysis of filtration properties of locally sourced base oil for the ...

    African Journals Online (AJOL)

    This study examines the use of locally sourced oil like, groundnut oil, melon oil, vegetable oil, soya oil and palm oil as substitute for diesel oil in formulating oil base drilling fluids relative to filtration properties. The filtrate volumes of each of the oils were obtained for filtration control analysis. With increasing potash and ...

  13. Establishing an ISO 10001-based promise in inpatients care.

    Science.gov (United States)

    Khan, Mohammad Ashiqur Rahman; Karapetrovic, Stanislav

    2015-01-01

    The purpose of this paper is to explore ISO 10001:2007 in planning, designing and developing a customer satisfaction promise (CSP) intended for inpatients care. Through meetings and interviews with research participants, who included a program manager, unit managers and registered nurses, information about potential promises and their implementation was obtained and analyzed. A number of promises were drafted and one was finally selected to be developed as a CSP. Applying the standard required adaptation and novel interpretation. Additionally, ISO 10002:2004 (Clause 7) was used to design the feedback handling activities. A promise initially chosen for development turned out to be difficult to implement, experience that helped in selecting and developing the final promise. Research participants found the ISO 10001-based method useful and comprehensible. This paper presents a specific health care example of how to adapt a standard's guideline in establishing customer promises. The authors show how a promise can be used in alleviating an existing issue (i.e. communication between carers and patients). The learning can be beneficial in various health care settings. To the knowledge, this paper shows the first example of applying ISO 10001:2007 in a health care case. A few activities suggested by the standard are further detailed, and a new activity is introduced. The integrated use of ISO 10001:2007 and 10002:2004 is presented and how one can be "augmented" by the other is demonstrated.

  14. Tangential filtration technologies membrane and applications for the industry agribusiness

    International Nuclear Information System (INIS)

    Leone, Gian Paolo; Russo, Claudio

    2015-01-01

    The membrane tangential filtration technologies are separation techniques based on the use of semipermeable filters through which, under a pushing force, it is possible to achieve separation of components or suspended in solution as a function of their dimensional characteristics and / or chemical-physical. At the laboratories of the ENEA Research Center Casaccia, as part of the program activities of the Biotechnology and agro-industry division, were studied and developed various filtration processes to membrane in the food industry. The problems have been studied by following a vision sustainable overall, always trying to pair the purification treatment to that of recovery and reuse of water and high value-added components. Ultimate goal of the research conducted is to close the production circuit, ensuring a discharge cycle zero and turning in fact a so-called spread in first, from which to obtain new products. [it

  15. Polymer filtration: A new technology for selective metals recovery

    Energy Technology Data Exchange (ETDEWEB)

    Smith, B.F.; Robison, T.W.; Cournoyer, M.E.; Wilson, K.V.; Sauer, N.N.; Mullen, K.I.; Lu, M.T.; Jarvinen, J.J.

    1995-04-01

    Polymer Filtration (PF) was evaluated for the recovery of electroplating metal ions (zinc and nickel) from rinse waters. Polymer Filtration combines the use of water-soluble metal-binding polymers and ultrafiltration to concentrate metal ions from dilute rinse water solutions. The metal ions are retained by the polymers; the smaller, unbound species freely pass through the ultrafiltration membrane. By using this process the ultrafiltered permeate more than meets EPA discharge limits. The metal ions are recovered from the concentrated polymer solution by pH adjustment using diafiltration and can be recycled to the original electroplating baths with no deleterious effects on the test panels. Metal-ion recovery is accomplished without producing sludge.

  16. Cast Steel Filtration Trials Using Ceramic-Carbon Filters

    Directory of Open Access Journals (Sweden)

    Lipowska B.

    2014-12-01

    Full Text Available Trials of cast steel filtration using two types of newly-developed foam filters in which carbon was the phase binding ceramic particles have been conducted. In one of the filters the source of carbon was flake graphite and coal-tar pitch, while in the other one graphite was replaced by a cheaper carbon precursor. The newly-developed filters are fired at 1000°C, i.e. at a much lower temperature than the currently applied ZrO2-based filters. During filtration trials the filters were subjected to the attack of a flowing metal stream having a temperature of 1650°C for 30 seconds.

  17. Controlling inclusions through filtration in investment casting process

    International Nuclear Information System (INIS)

    Ahmad, R.; Marshall, R.I.

    2004-01-01

    A technique for the placement of a ceramic foam filter in the feeding up of investment mould was developed which proved quite efficient in removing smaller and major inclusions through various filtration modes. Contaminated old aluminum scrap was used to prepare the melt without the addition of any cleansing and covering fluxes and the main reason was to produce more and more inclusions. Vigorous stirring was also intentionally carried out to form as much oxides as possible. During present research work effective filtration was observed. No leakage through sides of the filter occurred and similarly no choking was seen during feeding of molten metal. Microstructural studies showed the maximum retention of inclusions not only on the surface of filters but also within the various channels of the main body of the filter. The microstructures taken from the filtered test pieces were free from inclusions, which showed the effectiveness and proper placement of the filter. (author)

  18. Contaminated fluid filtration plant using pneumatically renewable granulated material

    International Nuclear Information System (INIS)

    Lucas, J.-C.; Messirejean, Pierre.

    1980-01-01

    This invention concerns a plant for the filtration of a contaminated fluid flow using a granulated material capable of absorbing or adsorbing the contaminants. This plant includes a filtration box within which there is at least one appreciably vertical filtering bed filled with the material and crossed by the fluid flow, loading and discharge compartments respectively located at the top and bottom of the box, each in communication with the filtering bed and an air-actuated transfer system for loading and discharging this bed through these compartments. Facilities of this kind are used mainly in the nuclear and chemical engineering industries to rid their waste of radio-iodines, generally constituted by elementary iodine and methyl iodide, or of toxic gases that contaminate them. The granulated material, whose job it is to trap these contaminants by adsorption or absorption, is generally composed of active carbon or zeolites whose utilisation time is limited [fr

  19. Filtration of droplets in the nose of the rabbit

    Energy Technology Data Exchange (ETDEWEB)

    Davies, C N

    1946-01-01

    Optical measurement was done on oil cloud sedimentation before and after passing through nose and out tracheal cannula. The filtering unit which also provides most resistance to flow is maximal turbinates. Nasal cavity is more complex than in man or some other animals, so filtration may be different. Calculation of particle inertia and filter channel width shows that particles > 7 ..mu..m would impact on curves or projections. Particles less than 1.5 ..mu..m should penetrate freely, but low molecular weight gases would be caught by diffusion. The higher the flow, the better the filtration (inertial settling). Broadly summarizing, at ordinary flow rates and nasal resistances, essentially all drops > 7 ..mu..m will be removed. About 50% of 3-..mu.. drops will be removed. < 1.5-..mu..m drops will penetrate.

  20. The use of an air filtration system in podiatry clinics.

    Science.gov (United States)

    McLarnon, Nichola; Burrow, Gordon; Maclaren, William; Aidoo, Kofi; Hepher, Mike

    2003-06-01

    A small-scale study was conducted to ascertain the efficiency and effectiveness of an air filtration system for use in podiatry/chiropody clinics (Electromedia Model 35F (A), Clean Air Ltd, Scotland, UK). Three clinics were identified, enabling comparison of data between podiatry clinics in the West of Scotland. The sampling was conducted using a portable Surface Air Sampler (Cherwell Laboratories, Bicester, UK). Samples were taken on two days at three different times before and after installation of the filtration units. The global results of the study indicate the filter has a statistically significant effect on microbial counts, with an average percentage decrease of 65%. This study is the first time, to the authors' knowledge, such a system has been tested within podiatric practice.

  1. Formation of siliceous sediments in brandy after diatomite filtration.

    Science.gov (United States)

    Gómez, J; Gil, M L A; de la Rosa-Fox, N; Alguacil, M

    2015-03-01

    Brandy is quite a stable spirit but sometimes light sediment appears. This sediment was separated and analysed by IR and SEM-EDX. It was revealed that the sediment is composed mostly of silica and residual organic matter. Silica was present as an amorphous phase and as microparticles. In an attempt to reproduce the formation of the sediment, a diatomite extract was prepared with an ethanol/water mixture (36% vol.) and a calcined diatomite similar to that used in brandy filtration. This extract was added to unfiltered brandy in different amounts. After 1 month, the Si concentration decreased in all samples and sediments with similar compositions and features to those found in the unstable brandy appeared. The amounts of sediment obtained were directly related to the decrease in Si concentration in solution. Consequently, it can be concluded that siliceous sediment in brandy originates from Si released during diatomite filtration. Copyright © 2014 Elsevier Ltd. All rights reserved.

  2. Validation of estimated glomerular filtration rate equations for Japanese children.

    Science.gov (United States)

    Gotoh, Yoshimitsu; Uemura, Osamu; Ishikura, Kenji; Sakai, Tomoyuki; Hamasaki, Yuko; Araki, Yoshinori; Hamda, Riku; Honda, Masataka

    2018-01-25

    The gold standard for evaluation of kidney function is renal inulin clearance (Cin). However, the methodology for Cin is complicated and difficult, especially for younger children and/or patients with bladder dysfunction. Therefore, we developed a simple and easier method for obtaining the estimated glomerular filtration rate (eGFR) using equations and values for several biomarkers, i.e., serum creatinine (Cr), serum cystatin C (cystC), serum beta-2 microglobulin (β 2 MG), and creatinine clearance (Ccr). The purpose of the present study was to validate these equations with a new data set. To validate each equation, we used data of 140 patients with CKD with clinical need for Cin, using the measured GFR (mGFR). We compared the results for each eGFR equation with the mGFR using mean error (ME), root mean square error (RMSE), P 30 , and Bland-Altman analysis. The ME of Cr, cystC, β 2 MG, and Ccr based on eGFR was 15.8 ± 13.0, 17.2 ± 16.5, 15.4 ± 14.3, and 10.6 ± 13.0 ml/min/1.73 m 2 , respectively. The RMSE was 29.5, 23.8, 20.9, and 16.7, respectively. The P 30 was 79.4, 71.1, 69.5, and 92.9%, respectively. The Bland-Altman bias analysis showed values of 4.0 ± 18.6, 5.3 ± 16.8, 12.7 ± 17.0, and 2.5 ± 17.2 ml/min/1.73 m 2 , respectively, for these parameters. The bias of each eGFR equation was not large. Therefore, each eGFR equation could be used.

  3. Development of injection moulded, ultrasonically welded immiscible phase filtration devices

    DEFF Research Database (Denmark)

    Kistrup, Kasper

    for ultrasonic welding, suitable for microfluidic systems. A methodology has been established where energy directors can be quickly added to existing mould inserts, using laser micromachining. The produced device was performance tested by isolating methicillin-resistant Staphylococcus aureus from bovine whole....... The device appliesmagnetic bead-based solid-phase extraction for nucleic acid extraction from biological samples, using the immiscible phase filtration (IPF) approach. Device development has employed injection moulding for part fabrication and ultrasonic welding for bonding. Rapid prototyping...

  4. Water Hyacinths and Alligator Weeds for Final Filtration of Sewage

    Science.gov (United States)

    Wolverton, B. C.; Mcdonald, R. C.; Gordon, J.

    1976-01-01

    The potential of water hyacinths (Eichhornia crassipes) (Mart.) Solms and alligator weeds (Alternanthera philoxerides) (Mart.) Griesb. as secondary and tertiary filtration systems for domestic sewage was demonstrated. These two vascular aquatic plants reduced the suspended solids, total Kjeldahl nitrogen, total phosphorus, BOD sub 5, and total organic carbon levels in domestic sewage from 60 percent to 98 percent within a two week period. These plants grown in domestic sewage were also free of toxic levels of trace heavy metals.

  5. Radioactive slurry waste treatment (1) - flucculant dose effects on filtration

    International Nuclear Information System (INIS)

    Jung, K. H.; Park, S. K.; Jung, W. S.; Baek, S. T.; Jung, K. J.

    1999-01-01

    During the past four decades, the radioactive slurry liquid waste(RSLW) is produced by operation of TRIGA Mark - II and III research reactors, producing radioisotopes and studying on RI utilization. Vacuum filtration of RSLW and flocculated RSLW with cationic, anionic and nonionic flocculants has been investigated. Test results show that critical dose of flocculant is obtained by the estimation of settling rate, cake moisture content and specific cake residence

  6. Cu filtration for dose reduction in neonatal chest imaging

    International Nuclear Information System (INIS)

    Smans, K.; Struelens, L.; Smet, M.; Bosmans, H.; Vanhavere, F.

    2010-01-01

    As neonatal chest images are frequently acquired to investigate the life-threatening lung diseases in prematurely born children, their optimisation in terms of X-ray exposure is required. The aim of this study was to investigate whether such dose-optimisation studies could be performed using a Monte Carlo computer model. More specifically, a Monte Carlo computer model was used to investigate the influence of Cu filtration on image quality and dose in neonatal chest imaging. Monte Carlo simulations were performed with the MCNPX code and used with voxel models representing prematurely born babies (590 and 1910 g). Physical image quality was derived from simulated images in terms of the signal difference-to-noise ratio and signal-to-noise ratio (SNR). To verify the simulation results, measurements were performed using the Gammex 610 Neonatal Chest Phantom, which represents a 1-2 kg neonate. A figure of merit was used to assist in evaluating the optimum balance between the image quality and the patient dose. The results show that the Monte Carlo computer model to investigate dose and image quality works well and can be used in dose-optimisation studies for real clinical practices. Furthermore, working at a specific constant incident air kerma (K a,I ), additional filtration proved to increase SNR with 30%, whereas working at a specific constant detector dose, extra Cu filtration reduces the lung dose with 25%. Optimum balance between patient dose and image quality is found to be 60 kVp (using extra filtration). (authors)

  7. Plasmapheresis and other extracorporeal filtration techniques in critical patients.

    Science.gov (United States)

    Daga Ruiz, D; Fonseca San Miguel, F; González de Molina, F J; Úbeda-Iglesias, A; Navas Pérez, A; Jannone Forés, R

    2017-04-01

    Plasmapheresis is an extracorporeal technique that eliminates macromolecules involved in pathological processes from plasma. A review is made of the technical aspects, main indications in critical care and potential complications of plasmapheresis, as well as of other extracorporeal filtration techniques such as endotoxin-removal columns and other devices designed to eliminate cytokines or modulate the inflammatory immune response in critical patients. Copyright © 2016 Elsevier España, S.L.U. y SEMICYUC. All rights reserved.

  8. Novel Particulate Air-Filtration Media: Market Survey

    Science.gov (United States)

    2013-02-01

    larger and more efficient filter designs similar to those being considered for future integrated respirator/helmet systems. To avoid eliminating ...including nonwoven, woven, and electret and combinations of media. Some of the manufacturers identified themselves as specializing in biofiltration or...Three Millipore products were identified. The 0.2 µm hydrophobic Aervent PTFE membrane62 is used for the sterile filtration of gases . Aerex

  9. Hazard categorization of K Basin water filtration upgrade project

    International Nuclear Information System (INIS)

    Conn, K.R.

    1995-01-01

    This supporting document provides the hazards categorization for the K Basin Water Filtration Upgrade Project at K East. All activities associated with the project are less than Hazard Category 3, except for the handling of the ECO-ROK liners containing spent filter cartridges. All activities involving the handling of liners, containing spent cartridges, by monorail, forklift or mobile crane are classified as Hazard Category 3

  10. Modeling Manganese Sorption and Surface Oxidation During Filtration

    OpenAIRE

    Bierlein, Kevin Andrew

    2012-01-01

    Soluble manganese (Mn) is a common contaminant in drinking water sources. High levels of Mn can lead to aesthetic water quality problems, necessitating removal of Mn during treatment to minimize consumer complaints. Mn may be removed during granular media filtration by the â natural greensand effect,â in which soluble Mn adsorbs to manganese oxide-coated (MnOx(s)) media and is then oxidized by chlorine, forming more manganese oxide. This research builds on a previous model developed by Mer...

  11. Corrosion-product filtration in PWRs: Topical report

    International Nuclear Information System (INIS)

    Balakrishnan, P.V.; Buckley, L.P.

    1988-04-01

    As part of a programme on the optimization of pressurized water reactor (PWR) secondary side water treatment, laboratory-scale studies on filtration of the feedwater using materials having chemically active adsorbing surfaces were carried out. Graphite, zirconia and titania were identified, from a review of existing literature, as suitable filtration media, the last two because of their ion-exchange capability. The efficiency of filters packed with granular graphite for filtration of simulated feed train corrosion products and the pressure drop across the filters were determined as functions of filter dimensions and operating parameters at room temperature. A rough sizing of a full-flow feedwater filter using granular graphite was done on the basis of observations from the room temperature tests. Further studies are suggested at low concentrations of the corrosion product and at high temperature typical of steam generator feedwater after the high pressure heaters to derive realistic design parameters for a filter for installation in the PWR secondary circuit. Zirconia was produced in the form of spherical particles using a sol-gel process. The zirconia behaved as an anion exchanger at low pH and as a cation exchanger at high pH. Its suitability for purification of water at high temperature should be determined by futher studies. 30 refs., 16 figs., 8 tabs

  12. Centrifugal Filtration System for Severe Accident Source Term Treatment

    Energy Technology Data Exchange (ETDEWEB)

    Liu, Shu Chang; Yim, Man Sung [KAIST, Daejeon (Korea, Republic of)

    2016-05-15

    The objective of this paper is to present the conceptual design of a filtration system that can be used to process airborne severe accident source term. Reactor containment may lose its structural integrity due to over-pressurization during a severe accident. This can lead to uncontrolled radioactive releases to the environment. For preventing the dispersion of these uncontrolled radioactive releases to the environment, several ways to capture or mitigate these radioactive source term releases are under investigation at KAIST. Such technologies are based on concepts like a vortex-like air curtain, a chemical spray, and a suction arm. Treatment of the radioactive material captured by these systems would be required, before releasing to environment. For current filtration systems in the nuclear industry, IAEA lists sand, multi-venturi scrubber, high efficiency particulate arresting (HEPA), charcoal and combinations of the above in NS-G-1-10, 4.143. Most if not all of the requirements of the scenario for applying this technology near the containment of an NPP site and the environmental constraints were analyzed for use in the design of the centrifuge filtration system.

  13. Filtration behavior of organic substance through a compacted bentonite

    International Nuclear Information System (INIS)

    Kanaji, Mariko; Kuno, Yoshio; Yui, Mikazu

    1999-07-01

    Filtration behavior of organic substance through a compacted bentonite was investigated. Na-type bentonite containing 30wt% of quartz sand was compacted in a column and the dry density was adjusted to be 1.6 g/cm 3 . Polyacrylic acid solution (including three types of polyacrylic acid, average molecular weight 2,100, 15,000 and 450,000) was prepared and was passed through the compacted bentonite. Molecular weight distributions of polyacrylic acid in the effluent solution were analysed by GPC (Gel Permeation Chromatography). A batch type experiment was also carried out in order to examine a sorption behavior of these organic substances onto the surfaces of grains of the bentonite. The results indicated that the smaller size polyacrylic acid (molecular weight < 100,000) was passed through the compacted bentonite. On the other hand, the larger size polyacrylic acid (molecular weight ≥100,000) was mostly filtrated by the compacted bentonite. The batch type sorption tests clarified that the polyacrylic acid did not sorb onto the surfaces of minerals constituting the bentonite. Therefore it was suggested that the larger size molecules (≥100,000) of organic substances could be predominantly filtrated by the microstructure of the compacted bentonite. (author)

  14. Experience with high-temperature filtration of incinerator flue gases

    International Nuclear Information System (INIS)

    Carpentier, S.; de Tassigny, C.

    1990-01-01

    It is always preferable to filter incinerator flue gases as close as possible to their origin, i.e. in a high-temperature zone, and means must be provided to destroy the other organic parts of the flyash resulting from these gases by in-filter combustion. The filter also traps a mineral part of the flyash, which eventually causes clogging and requires replacement or regeneration. Such filtration systems are available and can be operated on an industrial scale. They include candles made of micro-expanded refractory alloys supporting filtering media, porous ceramic candles and other devices. Research and subsequent pilot facility testing have enabled development of alumina fiber filter cartridges that offer more advantages than other equipment employed to date. Specifically, these advantages are: ultralight weight, which enables construction of systems that are relatively unaffected by creep and high-temperature deformations; excellent refractory qualities, which permit a use above 1000 degrees C; insensitivity to thermal shocks and in-situ carbon fines combustion capability; anti-acid quality of the material, which enables high-temperature filtration of acidic flue gases (chlorine and hydrochloric acid, SO x , etc.); low initial pressure drop of the cartridges; dimensional stability of the cartridges, which can be machined to a given tolerance with specific contours after casting and drying. This paper reports the results obtained during the last filtration system test campaign. Details are given for operating conditions, grain sizes and real-time monitoring of various parameters

  15. Improvement of municipal wastewater pretreatment by direct membrane filtration.

    Science.gov (United States)

    Nascimento, Thiago A; Mejía, Fanny R; Fdz-Polanco, Fernando; Peña Miranda, Mar

    2017-10-01

    The high content of particulate matter in municipal wastewater hinders the conventional anaerobic treatments at psychrophilic temperatures. The hydrolysis of the particulate chemical oxygen demand (pCOD) could be the limiting step under these conditions. Therefore, new pretreatments or improved conventional pretreatments are needed in order to separate pCOD. In this work, direct membrane filtration of municipal wastewater, using an ultrafiltration membrane, was investigated. This intensive pretreatment, which aims to separate soluble chemical oxygen demand (sCOD) and to concentrate pCOD, together with anaerobic treatments of both streams at psychrophilic and mesophilic conditions respectively, could be an alternative to the conventional activated sludge process. The obtained results show a removal yield of 24.9% of the total solids (TS) and 45% of total chemical oxygen demand (tCOD), obtaining a permeate free of suspended solids. This physical removal implies the accumulation of solids inside the membrane tank, reaching the values of 45.4 and 4.4 g/L of TS in the sedimentation and filtration sections, respectively. The membrane operated with filtration, backwashing cycles and continuous gas sparging, with a permeate flux predominantly around 10 L/(m 2  h). The results show the viability of the technology to concentrate pCOD and so to improve energy recovery from municipal wastewater.

  16. Active osmotic exchanger for advanced filtration at the nano scale

    Science.gov (United States)

    Marbach, Sophie; Bocquet, Lyderic

    2015-11-01

    One of the main functions of the kidney is to remove the waste products of an organism, mostly by excreting concentrated urea while reabsorbing water and other molecules. The human kidney is capable of recycling about 200 liters of water per day, at the relatively low cost of 0.5 kJ/L (standard dialysis requiring at least 150 kJ/L). Kidneys are constituted of millions of parallel filtration networks called nephrons. The nephrons of all mammalian kidneys present a specific loop geometry, the Loop of Henle, that is believed to play a key role in the urinary concentrating mechanism. One limb of the loop is permeable to water and the other contains sodium pumps that exchange with a common interstitium. In this work, we take inspiration from this osmotic exchanger design to propose new nanofiltration principles. We first establish simple analytical results to derive general operating principles, based on coupled water permeable pores and osmotic pumps. The best filtration geometry, in terms of power required for a given water recycling ratio, is comparable in many ways to the mammalian nephron. It is not only more efficient than traditional reverse osmosis systems, but can also work at much smaller pressures (of the order of the blood pressure, 0.13 bar, as compared to more than 30 bars for pressure-retarded osmosis systems). We anticipate that our proof of principle will be a starting point for the development of new filtration systems relying on the active osmotic exchanger principle.

  17. Evaluation of multistage filtration to reduce sand filter exhaust activity

    International Nuclear Information System (INIS)

    Zippler, D.B.

    1975-01-01

    Air from the Savannah River Plant Fuel Reprocessing facilities is filtered through deep bed sand filters consisting of 8 1 / 2 feet of gravel and sand. These filters have performed satisfactorily for the past 18 years in maintaining radioactive release levels to a minimum. The apparent filter efficiency has been determined for many years by measurements of the quantity of radioactivity in the air stream before and after the filter. Such tests have indicated efficiencies of 99.9 percent or better. Even with sand filter efficiency approaching a single stage HEPA filter, new emphasis on further reduction in release of plutonium activity to the environment prompted a study to determine what value backup HEPA filtration could provide. To evaluate the specific effect additional HEPA filtration would have on the removal of Pu from the existing sand filter exhaust stream, a test was conducted by passing a sidestream of sand-filtered air through a standard 24 x 24 x 11 1 / 2 in. HEPA filter. Isokinetic air samples were withdrawn upstream and downstream of the HEPA filter and counted for alpha activity. Efficiency calculations indicated that backup HEPA filtration could be expected to provide an additional 99 percent removal of the Pu activity from the present sand-filter exhaust. (U.S.)

  18. Field Demonstration of Fuel Crud Filtration System at Ulchin Plant

    International Nuclear Information System (INIS)

    Kang, Duk-Won; Lee, Doo-Ho; Park, Jong-Youl; Choi, In-Kyu

    2007-01-01

    Crud deposited onto the fuel assemblies in nuclear power plants was not a serious problem until an upper core flux depression named Axial Offset Anomaly (AOA) was found at Callaway, USA in 1989. Though the mechanism of an AOA is not completely understood, crud is believed to be a key component of initiating AOA. After the sufficient amount of corrosion products in the reactor cooling system are deposited on the fuel clad by a sub-cooled nucleate boiling, boron is adsorbed in the crud. Thus a measurable reduction in the neutron flux occurs which causes an AOA problem. A filtration system has been developed to remove the fuel crud from irradiated fuel assemblies for mitigating the axial offset anomaly under a technical cooperation agreement with DEI (Dominion Engineering Inc.). This filtration system with a fuel cleaning fixture was successfully demonstrated at Ulchin plant unit 2. Within several minutes, detachable crud deposits were effectively removed from the clad surfaces of the fuel assembly. Also, to characterize the crud particles for each fuel assembly, a small crud sampling device and radiation monitor devices were connected to the filtration system during the cleaning operation. In this study, we completed a functional test and demonstration of an ultrasonic fuel cleaning system by using four spent fuel assemblies. It took only 5 minutes to remove the fuel crud from each fuel assembly. In addition, collective dose rates indicated an average of 8 R/Hr per assembly

  19. Modeling the filtration ability of stockpiled filtering facepiece

    Science.gov (United States)

    Rottach, Dana R.

    2016-03-01

    Filtering facepiece respirators (FFR) are often stockpiled for use during public health emergencies such as an infectious disease outbreak or pandemic. While many stockpile administrators are aware of shelf life limitations, environmental conditions can lead to premature degradation. Filtration performance of a set of FFR retrieved from a storage room with failed environmental controls was measured. Though within the expected shelf life, the filtration ability of several respirators was degraded, allowing twice the penetration of fresh samples. The traditional picture of small particle capture by fibrous filter media qualitatively separates the effect of inertial impaction, interception from the streamline, diffusion, settling, and electrostatic attraction. Most of these mechanisms depend upon stable conformational properties. However, common FFR rely on electrets to achieve their high performance, and over time heat and humidity can cause the electrostatic media to degrade. An extension of the Langevin model with correlations to classical filtration concepts will be presented. The new computational model will be used to predict the change in filter effectiveness as the filter media changes with time.

  20. Design and verification of additional filtration for the application of ecological transmission and hydraulic fluids in tractorc

    Directory of Open Access Journals (Sweden)

    Pavel Máchal

    2013-01-01

    Full Text Available This contribution presents the design and function verification of additional filtration. It is intended for the common transmission and hydraulic oil filling of tractors. The main role of this filtration concept is to ensure a high level of oil cleanness as a condition for the application of ecologic fluids in tractors. The next one is to decrease the wear of lubricated tractor components, the degradation of oil and eventually to extend the interval of oil change. The designed additional filtering is characterized by ease installation through the use of quick couplings and hoses to the external hydraulic circuit. Therefore, the filtration is suitable for various tractor types. Filter element has been designed with the filter ability 1micron and the ability to separate to 0.5 dm3 of water from oil. Function of additional filtration was verified during the 150 engine hours of tractor operation. During this time period the oil contamination was evaluated on the basis of chemical elements content such as Fe, Cu, Si, Al, Ni, Mo and Cr. The additive concentration was evaluated on the basis of chemical elements content such as Ca, P and Zn. During the test operation of tractor the concentration decrease of chemical elements reached the values 25.53 % (Fe, 23.53 % (Si, 25 % (Al and 5.5 % (Cu. The decrease of additive concentration reached only medium level (6.6 %. Therefore, the designed additional filtration doesn’t remove additives from oil. Based on the evaluation of the content of chemical elements (that representing contamination and additives, we can say that the designed filtering method is suitable for use in agricultural tractors.

  1. Evaluating efficacy of filtration + UV-C radiation for ballast water treatment at different temperatures

    Science.gov (United States)

    Casas-Monroy, Oscar; Linley, Robert D.; Chan, Po-Shun; Kydd, Jocelyn; Vanden Byllaardt, Julie; Bailey, Sarah

    2018-03-01

    To prevent new ballast water-mediated introductions of aquatic nonindigenous species (NIS), many ships will soon use approved Ballast Water Management Systems (BWMS) to meet discharge standards for the maximum number of viable organisms in ballast water. Type approval testing of BWMS is typically conducted during warmer seasons when plankton concentrations are highest, despite the fact that ships operate globally year-round. Low temperatures encountered in polar and cool temperate climates, particularly during the winter season, may impact treatment efficacy through changes in plankton community composition, biological metabolic rates or chemical reaction rates. Filtration + UV irradiance is one of the most common ballast water treatment methods, but its effectiveness at low temperatures has not been assessed. The objective in this study was to examine the efficacy of filtration + UV-C irradiation treatment at low temperatures for removal or inactivation of phytoplankton and zooplankton populations during simulated ballast water treatment. Organisms from two size classes (≥ 10 to < 50 μm and ≥ 50 μm) were identified and enumerated using microscope and culture techniques. The response of organisms in both size categories to UV-C irradiation was evident across a range of temperatures (18 °C, 12 °C and 2 °C) as a significant decrease in concentration between controls and treated samples. Results indicate that filtration + UV-C irradiation will be effective at low temperatures, with few viable organisms ≥ 10 to < 50 μm recorded even 21 days following UV exposure (significantly lower than in the control treatment).

  2. Sorption Regularities in Behaviour of Fission-Product Elements during Filtration of their Solutions through Ground

    Energy Technology Data Exchange (ETDEWEB)

    Spitsyn, V. I.; Balukova, V. D.; Gromov, V. V.; Zakharov, S. I.; Zhagin, B. P.; Spiridonov, F. M.

    1960-07-01

    Research on the sorption of radioisotopes under natural conditions employing the controlled filtration process was performed. Radioisotopes were introduced into the solution as soon as filtration had become steady and the process continued for four months. Soil samples were then taken by drilling at different depths and analysed to determine their radioisotope content. Diffusion of radioisotopes was observed at depths of up to 10 m; two distinct boundaries of soil-activity decrease were ascertained: at the surface of the site and at the depth of the solution filtration front. In addition, the radiostrontium absorption by natural sorbents, principally pure minerals widely distributed in soils and subsoils, was investigated separately. The presence of calcium ions, even in small quantities, sharply reduces the degree of radiostrontium sorption. However, other conditions being equal, strontium may be absorbed to a greater extent than calcium, according to the composition of the sorbent. The field investigations of radiostrontium sorption and migration showed that when filtering radioactive solutions two possible variants have to be taken into account. In the first case the solutions are discharged into soil unaffected by any flow of ground water. In this situation the radiostrontium is retained by the soil. In the second case, the radioisotopes proceed directly into the water-bearing horizon. The radiostrontium will then migrate with the ground water flow and through the soil and this migration will be further affected by the sorption and desorption processes occurring. The experiments performed demonstrate the ease with which long-lived radioisotopes migrate under natural conditions and call attention to the need for thorough study of ground water problems in connexion with various methods of disposing of radioactive waste into ground. (author)

  3. Oak Ridge National Laboratory Melton Valley Storage Tanks Waste filtration process evaluation

    International Nuclear Information System (INIS)

    Walker, B.W.; McCabe, D.J.

    1997-01-01

    The purpose of this filter study was to evaluate cross-flow filtration as effective solid-liquid separation technology for treating Oak Ridge National Laboratory wastes, outline operating conditions for equipment, examine the expected filter flow rates, and determine proper cleaning.The Gunite Tanks at the Oak Ridge National Laboratory contain heels which are a mixture of sludge, wash water, and bentonite clay. The tanks are to be cleaned out with a variety of flushing techniques and the dilute mixture transferred to another storage tank. One proposal is to transfer this mixture into existing Melton Valley Storage Tanks (MVST), which already contain a large amount of sludge and supernate. The mixed aqueous phase will then be transferred to new MVST, which are prohibited from containing insoluble solids. To separate the solid from the liquid and thereby prevent solids transfer into the new MVST, a technique is needed that can cleanly separate the sludge and bentonite clay from the supernate. One proposed method for solid liquid separation is cross-flow filtration. Cross-flow filtration has been used at the Savannah River and West Valley sites for treatment of tank waste, and is being tested for applicability at other sites. The performance of cross-flow filters with sludge has been tested, but the impact of sludge combined with bentonite clay has not. The objective of this test was to evaluate the feasibility of using cross-flow filters to perform the solid liquid separation required for the mixture of Gunite and MVST tank wastes

  4. Realizing the promises of marine biotechnology

    NARCIS (Netherlands)

    Luiten, EEM; Akkerman, [No Value; Koulman, A; Kamermans, P; Reith, H; Barbosa, MJ; Sipkema, D; Wijffels, RH

    High-quality research in the field of marine biotechnology is one of the key-factors for successful innovation in exploiting the vast diversity of marine life. However, fascinating scientific research with promising results and claims on promising potential applications (e.g. for pharmaceuticals,

  5. Realizing the promises of marine biotechnology

    NARCIS (Netherlands)

    Luiten, E.E.M.; Akkerman, I.; Koulman, A.; Kamermans, P.; Reith, H.; Barbosa, M.J.; Sipkema, D.; Wijffels, R.H.

    2003-01-01

    High-quality research in the field of marine biotechnology is one of the key-factors for successful innovation in exploiting the vast diversity of marine life. However, fascinating scientific research with promising results and claims on promising potential applications (e.g. for pharmaceuticals,

  6. Tennessee Promise: A Response to Organizational Change

    Science.gov (United States)

    Littlepage, Ben; Clark, Teresa; Wilson, Randal; Stout, Logan

    2018-01-01

    Community colleges in Tennessee, either directly or indirectly, experienced unprecedented change as a result of Tennessee Promise. The present study explored how student support service administrators at three community colleges responded to organizational change as a result of the Tennessee Promise legislation. Investigators selected community…

  7. Preliminary evaluation of fungicidal and termiticidal activities of filtrates from biomass slurry fuel production

    Energy Technology Data Exchange (ETDEWEB)

    Kartal, S.N. [Istanbul University (Turkey). Forestry Faculty; Imamura, Y. [Kyoto University (Japan). Wood Research Institute; Tsuchiya, F.; Ohsato, K. [JGC Corporation, Yokohama (Japan)

    2004-10-01

    Biomass slurry fuel (BSF) production has recently been developed as a natural energy for the conversion of solid biomass into fuel. In addition to using fuel, filtrates from BSF production may also serve a chemical source with several organic compounds. There is an increasing interest in the research and application of biomass-based filtrates. In this study, fungicidal and termiticidal properties of filtrates from BSF production using sugi (Cryptomeria japonica) and acacia (Acacia mangium) wood were evaluated in laboratory decay and termite resistance tests. Wood blocks treated with the filtrates showed increased resistance against brown-rot fungus, Formitopsis palustris. However the filtrates from sugi wood processed at 270{sup o}C which contained less phenolic compounds than the other filtrates were effective against white-rot fungus, Trametes versicolor. Phenolic compounds of filtrates seemed to play a role in the decay resistance tests however the filtrates did not increase the durability of the wood blocks against subterranean termites Coptotermes formosanus. Despite high acetic and lactic acid content of the filtrates, vanillin content of the filtrates may have served as an additional food source and promoted termite attack. It can be concluded that filtrates with phenolic compounds from lignin degradation during BSF production can be considered for targeted inhibition of brown-rot. (author)

  8. GPU-Based Cloud Service for Smith-Waterman Algorithm Using Frequency Distance Filtration Scheme

    Directory of Open Access Journals (Sweden)

    Sheng-Ta Lee

    2013-01-01

    Full Text Available As the conventional means of analyzing the similarity between a query sequence and database sequences, the Smith-Waterman algorithm is feasible for a database search owing to its high sensitivity. However, this algorithm is still quite time consuming. CUDA programming can improve computations efficiently by using the computational power of massive computing hardware as graphics processing units (GPUs. This work presents a novel Smith-Waterman algorithm with a frequency-based filtration method on GPUs rather than merely accelerating the comparisons yet expending computational resources to handle such unnecessary comparisons. A user friendly interface is also designed for potential cloud server applications with GPUs. Additionally, two data sets, H1N1 protein sequences (query sequence set and human protein database (database set, are selected, followed by a comparison of CUDA-SW and CUDA-SW with the filtration method, referred to herein as CUDA-SWf. Experimental results indicate that reducing unnecessary sequence alignments can improve the computational time by up to 41%. Importantly, by using CUDA-SWf as a cloud service, this application can be accessed from any computing environment of a device with an Internet connection without time constraints.

  9. Apical sealing of root canal fillings performed with five different endodontic sealers: analysis by fluid filtration

    Directory of Open Access Journals (Sweden)

    Bruno Carvalho de Vasconcelos

    2011-08-01

    Full Text Available OBJECTIVES: To evaluate the sealing ability of five root canal sealers, including two experimental cements (MBP and MTA-Obtura using the fluid filtration method. MATERIAL AND METHODS: Teeth were divided into 5 study groups: G1-AH Plus; G2-Acroseal; G3Sealapex; G4-MBP; G5-MTA-Obtura; and two controls. Chemical-mechanical preparation was performed with ProFile rotary nickel-titanium instruments 1 mm short of the apical foramen. The sealing ability was evaluated by fluid filtration at 15, 30, and 60 days. RESULTS: The statistical analysis showed significant difference between the materials at different periods (p<0.05. AH Plus and MBP had similar leakage values at 15 and 60 days, alternating with significant reduction at 30 days, while the other materials showed progressive increase in leakage values. Acroseal and Sealapex presented the best results at 15 days and the worst at 60 days. CONCLUSIONS: All sealers evaluated presented fluid leakage, with AH Plus and MBP showing the best results at the end of the experimental period. Acroseal, Sealapex, and MTA-Obtura presented increase in leakage values at longer observation periods.

  10. Automatic Reporting of Creatinine-Based Estimated Glomerular Filtration Rate in Children: Is this Feasible?

    Directory of Open Access Journals (Sweden)

    Andrew Lunn

    2016-07-01

    Full Text Available Creatinine, although widely used as a biomarker to measure renal function, has long been known as an insensitive marker of renal impairment. Patients with reduced renal function can have a creatinine level within the normal range, with a rapid rise when renal function is significantly reduced. As of 1976, the correlation between height, the reciprocal of creatinine, and measured glomerular filtration rate (GFR in children has been described. It has been used to derive a simple formula for estimated glomerular filtration rate (eGFR that could be used at the bedside as a more sensitive method of identifying children with renal impairment. Formulae based on this association, with modifications over time as creatinine assay methods have changed, are still widely used clinically at the bedside and in research studies to assess the degree of renal impairment in children. Adult practice has moved in many countries to computer-generated results that report eGFR alongside creatinine results using more complex, but potentially more accurate estimates of GFR, which are independent of height. This permits early identification of patients with chronic kidney disease. This review assesses the feasibility of automated reporting of eGFR and the advantages and disadvantages of this in children.

  11. GPU-based cloud service for Smith-Waterman algorithm using frequency distance filtration scheme.

    Science.gov (United States)

    Lee, Sheng-Ta; Lin, Chun-Yuan; Hung, Che Lun

    2013-01-01

    As the conventional means of analyzing the similarity between a query sequence and database sequences, the Smith-Waterman algorithm is feasible for a database search owing to its high sensitivity. However, this algorithm is still quite time consuming. CUDA programming can improve computations efficiently by using the computational power of massive computing hardware as graphics processing units (GPUs). This work presents a novel Smith-Waterman algorithm with a frequency-based filtration method on GPUs rather than merely accelerating the comparisons yet expending computational resources to handle such unnecessary comparisons. A user friendly interface is also designed for potential cloud server applications with GPUs. Additionally, two data sets, H1N1 protein sequences (query sequence set) and human protein database (database set), are selected, followed by a comparison of CUDA-SW and CUDA-SW with the filtration method, referred to herein as CUDA-SWf. Experimental results indicate that reducing unnecessary sequence alignments can improve the computational time by up to 41%. Importantly, by using CUDA-SWf as a cloud service, this application can be accessed from any computing environment of a device with an Internet connection without time constraints.

  12. Streamlined sample cleanup using combined dispersive solid-phase extraction and in-vial filtration for analysis of pesticides and environmental pollutants in shrimp

    Science.gov (United States)

    A new method of sample preparation was developed and is reported for the first time. The approach combines in-vial filtration with dispersive solid-phase extraction (d-SPE) in a fast and convenient cleanup of QuEChERS (quick, easy, cheap, effective, rugged, and safe) extracts. The method was appli...

  13. Determination of formaldehyde in frozen fish with formaldehyde dehydrogenase using a flow injection system with an incorporated gel-filtration chromatrography column

    DEFF Research Database (Denmark)

    Bechmann, Iben Ell

    1996-01-01

    in a FIA system. The FIA system is furnished with a gel-filtration chromatography column for on-line removal of the proteins from the extract before the enzymatic analysis is performed. Compared with the standard methods for determination of formaldehyde in fish products the present method is much faster...

  14. Determination of Formaldehyde in Frozen Fish with Formaldehyde Dehydrogenase Using a Flow Injection System with an Incorporated Gel-filtration Chromatography Column

    DEFF Research Database (Denmark)

    Bechmann, Iben Ellegaard

    1996-01-01

    in a FIA system. The FIA system is furnished with a gel-filtration chromatography column for on-line removal of the proteins from the extract before the enzymatic analysis is performed. Compared with the standard methods for determination of formaldehyde in fish products the present method is much faster...

  15. SimBa: An Efficient Tool for Approximating Rips-Filtration Persistence via Simplicial Batch-Collapse

    OpenAIRE

    Dey, Tamal K.; Shi, Dayu; Wang, Yusu

    2016-01-01

    In topological data analysis, a point cloud data P extracted from a metric space is often analyzed by computing the persistence diagram or barcodes of a sequence of Rips complexes built on $P$ indexed by a scale parameter. Unfortunately, even for input of moderate size, the size of the Rips complex may become prohibitively large as the scale parameter increases. Starting with the Sparse Rips filtration introduced by Sheehy, some existing methods aim to reduce the size of the complex so as to ...

  16. Peat filtration, field ditches and sedimentation basins for the purification of runoff water from peat mining areas

    International Nuclear Information System (INIS)

    Ihme, R.; Heikkinen, K.; Lakso, E.

    1991-01-01

    The aim of this research is to develop new methods and to improve those already in use to reduce the loading of watercourses from peat excavation areas. Factors examined were the use of peat filtration for the purification of the runoff water, load retention by the means of field ditches and improvement of the practicability and dredging of the settling ponds. Field research was carried out in peat production areas in the province of Oulu in 1987-1989

  17. Surface patterning of polymeric separation membranes and its influence on the filtration performance

    Science.gov (United States)

    Maruf, Sajjad

    Polymeric membrane based separation technologies are crucial for addressing the global issues such as water purification. However, continuous operations of these processes are often hindered by fouling which increases mass transport resistance of the membrane to permeation and thus the energy cost, and eventually replacement of the membrane in the system. In comparison to other anti-fouling strategies, the use of controlled surface topography to mitigate fouling has not been realized mainly due to the lack of methods to create targeted topography on the porous membrane surface. This thesis aims to develop a new methodology to create surface-patterned polymeric separation membrane to improve their anti-fouling characteristics during filtration. First, successful fabrication of sub-micron surface patterns directly on a commercial ultrafiltration (UF) membrane surface using nanoimprint lithographic (NIL) technique was demonstrated. Comprehensive filtration studies revealed that the presence of these sub-micron surface patterns mitigates not only the onset of colloidal particle deposition, but also lowers the rate of growth of cake layer after initial deposition, in comparison with un-patterned membranes. The anti-fouling effects were also observed for model protein solutions. Staged filtration experiments, with backwash cleaning, revealed that the permeate flux of the patterned membrane after protein fouling was considerably higher than that of the pristine or un-patterned membrane. In addition to the surface-patterning of UF membranes, successful fabrication of a surface-patterned thin film composite (TFC) membrane was shown for the first time. A two-step fabrication process was carried out by (1) nanoimprinting a polyethersulfone (PES) support using NIL, and (2) forming a thin dense film atop the PES support via interfacial polymerization (IP). Fouling experiments suggest that the surface patterns alter the hydrodynamics at the membrane-feed interface, which is

  18. High-performance thin-layer chromatographic methods in the evaluation of the antioxidant and anti-hyperglycemic activity of Myrmecodia platytyrea as a promising opportunity in diabetes treatment.

    Science.gov (United States)

    Agatonovic-Kustrin, S; Morton, D W; Adam, A; Mizaton, H H; Zakaria, H

    2017-12-29

    The steady increase of diabetes is becoming a major burden on health care systems. As diabetic complications arise from oxidative stress, an antioxidant therapy along with anti-diabetic drugs is recommended. Myrmecodia or ant plant is highly valued as a traditional medicine in West Papua. It is used as an alternative treatment for diabetes, as the substances produced by ants can reduce blood sugar levels. The aim of this study was to develop and establish high-performance thin-layer chromatographic (HPTLC)-bioautographic methods to measure the antioxidant and hypoglycemic effects in different extracts from Myrmecodia platytyrea and to compare them with sterol content. Antioxidant activity in methanol, ethanol, dichloromethane (DCM) and ethyl acetate (EA) extracts were measured with a direct HPTLC-2,2-diphenyl-1-picrylhydrazyl free radical (DPPH) assay, while hypoglycemic effects were assessed using a newly developed α-amylase inhibitory activity assay. Stigmasterol is observed, after derivatization with anisaldehyde, as purple colored zones under visible light at hRF values of 0.66. The highest antioxidant activity was observed in the ethanol extract which is rich in polyphenols and flavonoids, while the DCM extract did not show antioxidant activity, but had significant α-amylase inhibitory activity. The highest α-amylase inhibitory activity was observed in the EA and DCM extracts and was related to their stigmasterol content. Crown Copyright © 2017. Published by Elsevier B.V. All rights reserved.

  19. Medical big data: promise and challenges

    Directory of Open Access Journals (Sweden)

    Choong Ho Lee

    2017-03-01

    Full Text Available The concept of big data, commonly characterized by volume, variety, velocity, and veracity, goes far beyond the data type and includes the aspects of data analysis, such as hypothesis-generating, rather than hypothesis-testing. Big data focuses on temporal stability of the association, rather than on causal relationship and underlying probability distribution assumptions are frequently not required. Medical big data as material to be analyzed has various features that are not only distinct from big data of other disciplines, but also distinct from traditional clinical epidemiology. Big data technology has many areas of application in healthcare, such as predictive modeling and clinical decision support, disease or safety surveillance, public health, and research. Big data analytics frequently exploits analytic methods developed in data mining, including classification, clustering, and regression. Medical big data analyses are complicated by many technical issues, such as missing values, curse of dimensionality, and bias control, and share the inherent limitations of observation study, namely the inability to test causality resulting from residual confounding and reverse causation. Recently, propensity score analysis and instrumental variable analysis have been introduced to overcome these limitations, and they have accomplished a great deal. Many challenges, such as the absence of evidence of practical benefits of big data, methodological issues including legal and ethical issues, and clinical integration and utility issues, must be overcome to realize the promise of medical big data as the fuel of a continuous learning healthcare system that will improve patient outcome and reduce waste in areas including nephrology.

  20. Medical big data: promise and challenges.

    Science.gov (United States)

    Lee, Choong Ho; Yoon, Hyung-Jin

    2017-03-01

    The concept of big data, commonly characterized by volume, variety, velocity, and veracity, goes far beyond the data type and includes the aspects of data analysis, such as hypothesis-generating, rather than hypothesis-testing. Big data focuses on temporal stability of the association, rather than on causal relationship and underlying probability distribution assumptions are frequently not required. Medical big data as material to be analyzed has various features that are not only distinct from big data of other disciplines, but also distinct from traditional clinical epidemiology. Big data technology has many areas of application in healthcare, such as predictive modeling and clinical decision support, disease or safety surveillance, public health, and research. Big data analytics frequently exploits analytic methods developed in data mining, including classification, clustering, and regression. Medical big data analyses are complicated by many technical issues, such as missing values, curse of dimensionality, and bias control, and share the inherent limitations of observation study, namely the inability to test causality resulting from residual confounding and reverse causation. Recently, propensity score analysis and instrumental variable analysis have been introduced to overcome these limitations, and they have accomplished a great deal. Many challenges, such as the absence of evidence of practical benefits of big data, methodological issues including legal and ethical issues, and clinical integration and utility issues, must be overcome to realize the promise of medical big data as the fuel of a continuous learning healthcare system that will improve patient outcome and reduce waste in areas including nephrology.