WorldWideScience

Sample records for prolong catheter survival

  1. Prolonged use of indwelling urinary catheter following acute urinary ...

    African Journals Online (AJOL)

    J.O. Bello

    prolonged use of urinary catheters following acute urinary retention secondary to benign prostate enlarge- ment (BPE) and urethral ... indwelling urinary catheter for >3 months following acute urinary retention due to BPE or USD. The study .... the major health-care financing strategy in Nigeria and accounts for more than ...

  2. FACTORS AND COMPLICATIONS AFFECTING CATHETER AND TECHNIQUE SURVIVAL WITH PERMANENT SINGLE-LUMEN DIALYSIS CATHETERS

    NARCIS (Netherlands)

    DEMEESTER, J; VANHOLDER, R; DEROOSE, J; RINGOIR, S

    1994-01-01

    This long-term study on the outcome of permanent silicone single-lumen dialysis catheters consisted of 43 surgically inserted catheters in 33 patients. All catheters were attached to a pressure-pressure single-cannula dialysis system. Technique and catheter survival were 80 and 59% at 1 year, and 63

  3. Prolongation of islet allograft survival

    International Nuclear Information System (INIS)

    Lacy, P.E.; Davie, J.M.; Finke, E.H.; Scharp, D.W.

    1979-01-01

    Pretreatment of donor rats with irradiation and silica followed by in vitro culture of the islets for 1 to 2 days prolonged survival of allografts across a minor histocompatibility barrier if hand-picked, clean islets were used for transplantation. Pretreatment of donor rats with irradiation and silica in conjunction with a single injection of antilymphocyte serum (ALS) into the recipient produced a prolongation of survival of hand-picked islets transplanted across a major histocompatibility barrier

  4. Torsades de Pointes associated with QT prolongation after catheter ablation of paroxysmal atrial fibrillation

    Directory of Open Access Journals (Sweden)

    Yae Min Park

    2017-09-01

    Full Text Available A 79-year-old woman who underwent catheter ablation for paroxysmal atrial fibrillation presented with Torsades de Pointes (TdP. Aggravation of prolonged QT interval which is most likely due to neural modulation by catheter ablation, played major role in the initiation of TdP. The patient was successfully treated with isoproterenol during acute stage and discharged after stabilization without implantation of permanent pacemaker or implantable cardioverter defibrillator.

  5. Swan-neck versus straight peritoneal dialysis catheter: Long-term effect on patient and method survival.

    Science.gov (United States)

    Filiopoulos, V; Biblaki, D; Takouli, L; Dounavis, A; Hadjiyannakos, D; Vlassopoulos, D

    2016-09-01

    Peritoneal dialysis (PD) is limited mainly by a higher technique failure rate as compared to hemodialysis (HD), catheter malfunction being an important reason. Intra- and extra-peritoneal catheter configuration may be associated with mechanical and infectious complications affecting method survival. We report our experience with two extra-peritoneal catheter configurations: the straight and the swan-neck (SN) catheters. A total of 85 consecutive patients, 58 males and 27 females were included in the study. Among them, 26 were diabetics; 52 were treated with automated PD (APD) and 33 with continuous ambulatory PD (CAPD). Straight catheters were used in 38 patients (straight group) and SN catheters in 47 patients (SN group). Straight catheters were mostly used in the first 6-year period while SN catheters in the last 6-year period. The baseline demographics were similar between the two groups. A significantly higher frequency of APD use was observed in SN group. Technique survival was better with SN versus straight (log-rank test, P = 0.01) while patient and catheter survival were similar. A better technique survival is noted in our group of patients with SN catheters. An additional factor could be the significantly higher frequency of APD use in this group. Changes in PD solutions' composition could also contribute to improvement in technique survival. The outcome for patients and catheter types used was similar.

  6. SURVIVAL OF CONTINUOUS AMBULATORY PERITONEAL DIALYSIS CATHETERS: AN EVALUATION OF SURGICAL AND NON-SURGICAL FACTORS (SINGLE CENTER STUDY

    Directory of Open Access Journals (Sweden)

    A. Keshvari

    2006-06-01

    Full Text Available Peritoneal dialysis is an established form of renal replacement therapy used in many patients with end-stage renal disease. The key to a successful chronic peritoneal dialysis is a permanent and safe access to the peritoneal cavity. This study was conducted in order to evaluate the catheter survival and its related factors in Imam Khomeini Hospital. A total of 80 catheters were inserted into 69 patients (52 men and 28 women with end-stage chronic renal failure during a period of 84 months. Retrospectively the correlation between catheter survival (overall and event free with demographic factors (sex and age, surgical factors (surgeons and surgical methods, nephrologic factors (the causes of peritoneal dialysis selection and the history of hemodialysis and peritonitis factors (the history and number of peritonitis has been evaluated. The mean age of the patients was 48.35 years (16 to 79 years. The overall survival of catheters or the probability of having a functioning catheter after one, two and three years was 53%, 41%, 22%, respectively. The event free survival of the catheter or the probability of having a functioning catheter without any problems after one year was 14%. It has been found out that among all factors in this study only history of hemodialysis had statistically significant effect on the overall survival of continuous ambulatory peritoneal dialysis catheter (P = 0.04. It seems that the overall survival of catheters is better when CAPD is started before any other attempts for hemodialysis.

  7. In vivo assessment of catheter positioning accuracy and prolonged irradiation time on liver tolerance dose after single-fraction 192Ir high-dose-rate brachytherapy

    Directory of Open Access Journals (Sweden)

    Kropf Siegfried

    2011-09-01

    Full Text Available Abstract Background To assess brachytherapy catheter positioning accuracy and to evaluate the effects of prolonged irradiation time on the tolerance dose of normal liver parenchyma following single-fraction irradiation with 192 Ir. Materials and methods Fifty patients with 76 malignant liver tumors treated by computed tomography (CT-guided high-dose-rate brachytherapy (HDR-BT were included in the study. The prescribed radiation dose was delivered by 1 - 11 catheters with exposure times in the range of 844 - 4432 seconds. Magnetic resonance imaging (MRI datasets for assessing irradiation effects on normal liver tissue, edema, and hepatocyte dysfunction, obtained 6 and 12 weeks after HDR-BT, were merged with 3D dosimetry data. The isodose of the treatment plan covering the same volume as the irradiation effect was taken as a surrogate for the liver tissue tolerance dose. Catheter positioning accuracy was assessed by calculating the shift between the 3D center coordinates of the irradiation effect volume and the tolerance dose volume for 38 irradiation effects in 30 patients induced by catheters implanted in nearly parallel arrangement. Effects of prolonged irradiation were assessed in areas where the irradiation effect volume and tolerance dose volume did not overlap (mismatch areas by using a catheter contribution index. This index was calculated for 48 irradiation effects induced by at least two catheters in 44 patients. Results Positioning accuracy of the brachytherapy catheters was 5-6 mm. The orthogonal and axial shifts between the center coordinates of the irradiation effect volume and the tolerance dose volume in relation to the direction vector of catheter implantation were highly correlated and in first approximation identically in the T1-w and T2-w MRI sequences (p = 0.003 and p p = 0.001 and p = 0.004, respectively. There was a significant shift of the irradiation effect towards the catheter entry site compared with the planned dose

  8. Laparoscopic Placement of Peritoneal Dialysis Catheters in CAPD Patients: Complications and Survival

    Directory of Open Access Journals (Sweden)

    A Roueentan

    2008-06-01

    Full Text Available Background: Laparoscopic techniques for the placement of peritoneal dialysis catheters are becoming increasingly popular. Recently, with the improvements in laparoscopic surgery, various methods for the insertion of peritoneal dialysis catheters have been reported, indicating that the laparoscopic insertion is preferred over the open and percutaneous techniques. The aim of this study was to introduce and assess a simplified laparoscopic method for the insertion of peritoneal dialysis catheters in continuous ambulatory peritoneal dialysis (CAPD patients.Methods: We enrolled 79 consecutive end-stage renal patients (46 men and 33 women with a mean age of 50 years (range: 19-83 years in this study. During the surgery, a 5-mm trocar was placed in the left upper quadrant for the optics and another 5-mm trocar was placed to the left of the umbilicus. Using the second trocar, a tunnel was formed 2 cm left of the umbilical plane for the insertion of a Tenckhoff catheter. Under direct vision, the catheter was advanced into the abdomen. The catheter was tested for patency. Catheters of all subjects were capped for two weeks before dialysis initiation.Results: The mean duration of the operation was 15 minutes. Ten patients died during the follow-up period, all due to other medical problems, and six patients underwent renal transplantation; however, no deaths or complications were observed during surgery. Early onset complications were seen in 12 patients (15.1%. The most frequent late-onset medical and mechanical complications were peritonitis (6.3% and hernia (3.7%. During a follow-up period of four years, removal of the catheter was required in two patients as a result of peritonitis.Conclusion: We obtained a low complication rate and a high catheter survival rate with this laparoscopic insertion of the Tenckhoff catheter. We believe future experience will encourage the use of this safe, simple and quick procedure.

  9. Biological safety evaluation of the modified urinary catheter

    Energy Technology Data Exchange (ETDEWEB)

    Kowalczuk, Dorota, E-mail: dorota.kowalczuk@umlub.pl [Department of Medicinal Chemistry, Medical University of Lublin, Jaczewskiego 4, 20-090 Lublin (Poland); Przekora, Agata; Ginalska, Grazyna [Department of Biochemistry and Biotechnology, Medical University of Lublin, Chodzki 1, 20-093 Lublin (Poland)

    2015-04-01

    The purpose of this study was to evaluate in vitro safety of the novel tosufloxacin (TOS)-treated catheters with the prolonged antimicrobial activity. The test samples of silicone latex catheter were prepared by the immobilization of TOS on chitosan (CHIT)-coated catheter by means of covalent bonds and non-covalent interactions. Each step of the modification process of catheter surface was observed using ATR–Fourier transform infrared spectroscopy. In vitro cytotoxicity of the modified and unmodified catheters was assessed by direct and indirect tests in accordance with ISO standards using green monkey kidney (GMK) cell line. The MTT, lactate dehydrogenase activity (LDH), WST-8, Sulforhodamine B (SRB) test results and microscopic observation clearly indicated that unmodified silicone latex catheters decrease cell metabolic activity, act as a cytotoxic agent causing cell lysis and induce cell death through necrotic or apoptotic process. We suggest that chitosan coat with TOS immobilized limits leaching of harmful agents from silicone latex material, which significantly enhances survivability of GMK cells and therefore is quite a good protection against the cytotoxic effect of this material. - Highlights: • Characterization of the novel antimicrobial urinary catheters • Monitoring of the catheter modification by FTIR analysis • Confirmation of high cytotoxicity of latex-based catheter used in urological practice • Chitosan-coated and tosufloxacin-treated catheter is less toxic than the untreated one. • The proposed surface modification protects cells against latex-induced death.

  10. Prolonged minor allograft survival in intravenously primed mice--a test of the veto hypothesis

    International Nuclear Information System (INIS)

    Johnson, L.L.

    1987-01-01

    Experiments were performed to test the hypothesis that veto cells are responsible for the prolonged survival of minor allografts of skin that is observed in recipients primed intravenously with spleen cells from mice syngeneic with the skin donors. This prolonged survival was observed for each of several minor histocompatibility (H) antigens and is antigen-specific. Gamma radiation (3300 rads) abolished the ability of male spleen cells infused i.v. to delay the rejection of male skin grafts (H-Y antigen) on female recipients. However, depletion of Thy-1+ cells from the i.v. infusion failed to abolish the ability to prolong male skin graft survival. Furthermore, the prolonged survival accorded to B6 (H-2b) male skin grafts on CB6F1 (H-2b/H-2d) female recipients given i.v. infusions of B6 male spleen cells extended to BALB/c (H-2d) male skin grafts as well, indicating a lack of MHC restriction. Thus, prolongation of minor allograft survival by i.v. infusion of minor H antigen-bearing spleen cells appears not to depend on veto T cells that others have found to be responsible for the suppression of CTL generation

  11. Potentiation of ghrelin signaling attenuates cancer anorexia–cachexia and prolongs survival

    Science.gov (United States)

    Fujitsuka, N; Asakawa, A; Uezono, Y; Minami, K; Yamaguchi, T; Niijima, A; Yada, T; Maejima, Y; Sedbazar, U; Sakai, T; Hattori, T; Kase, Y; Inui, A

    2011-01-01

    Cancer anorexia–cachexia syndrome is characterized by decreased food intake, weight loss, muscle tissue wasting and psychological distress, and this syndrome is a major source of increased morbidity and mortality in cancer patients. This study aimed to clarify the gut–brain peptides involved in the pathogenesis of the syndrome and determine effective treatment for cancer anorexia–cachexia. We show that both ghrelin insufficiency and resistance were observed in tumor-bearing rats. Corticotropin-releasing factor (CRF) decreased the plasma level of acyl ghrelin, and its receptor antagonist, α-helical CRF, increased food intake of these rats. The serotonin 2c receptor (5-HT2cR) antagonist SB242084 decreased hypothalamic CRF level and improved anorexia, gastrointestinal (GI) dysmotility and body weight loss. The ghrelin receptor antagonist (D-Lys3)-GHRP-6 worsened anorexia and hastened death in tumor-bearing rats. Ghrelin attenuated anorexia–cachexia in the short term, but failed to prolong survival, as did SB242084 administration. In addition, the herbal medicine rikkunshito improved anorexia, GI dysmotility, muscle wasting, and anxiety-related behavior and prolonged survival in animals and patients with cancer. The appetite-stimulating effect of rikkunshito was blocked by (D-Lys3)-GHRP-6. Active components of rikkunshito, hesperidin and atractylodin, potentiated ghrelin secretion and receptor signaling, respectively, and atractylodin prolonged survival in tumor-bearing rats. Our study demonstrates that the integrated mechanism underlying cancer anorexia–cachexia involves lowered ghrelin signaling due to excessive hypothalamic interactions of 5-HT with CRF through the 5-HT2cR. Potentiation of ghrelin receptor signaling may be an attractive treatment for anorexia, muscle wasting and prolong survival in patients with cancer anorexia–cachexia. PMID:22832525

  12. Prolonged Delayed Graft Function Is Associated with Inferior Patient and Kidney Allograft Survivals.

    Directory of Open Access Journals (Sweden)

    Tainá Veras de Sandes-Freitas

    Full Text Available It is unclear if there is an association between the duration of delayed graft function (DGF and kidney transplant (KT outcomes. This study investigated the impact of prolonged DGF on patient and graft survivals, and renal function one year after KT. This single center retrospective analysis included all deceased donor KT performed between Jan/1998 and Dec/2008 (n = 1412. Patients were grouped in quartiles according to duration of DGF (1-5, 6-10, 11-15, and >15 days, designated as prolonged DGF. The overall incidence of DGF was 54.2%. Prolonged DGF was associated with retransplantation (OR 2.110, CI95% 1.064-4.184,p = 0.033 and more than 3 HLA mismatches (OR 1.819, CI95% 1.117-2.962,p = 0.016. The incidence of acute rejection was higher in patients with DGF compared with those without DGF (36.2% vs. 12.2%, p<0.001. Compared to patients without DGF, DGF(1-5, DGF(6-10, and DGF(11-15, patients with prolonged DGF showed inferior one year patient survival (95.2% vs. 95.4% vs. 95.5% vs. 93.4% vs. 88.86%, p = 0.003, graft survival (91% vs. 91.4% vs. 92% vs. 88.7% vs. 70.5%, p<0.001, death-censored graft survival (95.7% vs. 95.4% vs. 96.4% vs. 94% vs. 79.3%, p<0.001, and creatinine clearance (58.0±24.6 vs. 55.8±22.2 vs. 53.8±24.1 vs. 53.0±27.2 vs. 36.8±27.0 mL/min, p<0.001, respectively. Multivariable analysis showed that prolonged DGF was an independent risk factor for graft loss (OR 3.876, CI95% 2.270-6.618, p<0.001, death censored graft loss (OR 4.103, CI95% 2.055-8.193, p<0.001, and death (OR 3.065, CI95% 1.536-6.117, p = 0.001. Prolonged DGF, determined by retransplantation and higher HLA mismatches, was associated with inferior renal function, and patient and graft survivals at one year.

  13. Significant prolongation of hamster liver transplant survival in Lewis rats by total-lymphoid irradiation, cyclosporine, and splenectomy

    International Nuclear Information System (INIS)

    Yamaguchi, Y.; Halperin, E.C.; Harland, R.C.; Wyble, C.; Bollinger, R.R.

    1990-01-01

    The effects of total lymphoid irradiation, cyclosporine and splenectomy alone and in combination have been studied in liver transplants from the LVG hamster to the LEW rat. Neither CsA alone, splenectomy alone, nor TLI alone prolonged graft survival. CsA/splenectomy and TLI/CsA produced significant prolongation of graft survival. TLI/CsA/splenectomy prolonged graft survival by over sixfold compared with controls. While CsA alone was ineffective in reducing lymphocytotoxic antidonor antibody, splenectomy alone or CsA/splenectomy did significantly suppress production of antibody. Only very low levels of antibody could be detected in animals treated with TLI/CsA/splenectomy. TLI/CsA/splenectomy has an immunosuppressive effect sufficient to significantly prolong liver graft survival in the LVG hamster to LEW rat combination and may represent a promising treatment protocol in experimental cross-species transplantation

  14. Neonatal survival after prolonged preterm premature rupture of membranes before 24 weeks of gestation.

    Science.gov (United States)

    Brumbaugh, Jane E; Colaizy, Tarah T; Nuangchamnong, Nina; O'Brien, Emily A; Fleener, Diedre K; Rijhsinghani, Asha; Klein, Jonathan M

    2014-11-01

    To evaluate neonatal survival after prolonged preterm premature rupture of membranes (PROM) in the era of antenatal corticosteroids, surfactant, and inhaled nitric oxide. A single-center retrospective cohort study of neonates born from 2002-2011 after prolonged (1 week or more) preterm (less than 24 weeks of gestation) rupture of membranes was performed. The primary outcome was survival to discharge. Neonates whose membranes ruptured less than 24 hours before delivery (n=116) were matched (2:1) on gestational age at birth, sex, and antenatal corticosteroid exposure with neonates whose membranes ruptured 1 week or more before delivery (n=58). Analysis used conditional logistic regression for categorical data and Wilcoxon signed rank test for continuous data. The prolonged preterm PROM exposed and unexposed cohorts had survival rates of 90% and 95%, respectively, although underpowered to assess the statistical significance (P=.313). Exposed neonates were more likely have pulmonary hypoplasia (26/58 exposed, 1/114 unexposed, Prupture (20.4 weeks exposed, 22.3 weeks unexposed, P=.189), length of rupture (3.7 weeks exposed, 6.4 weeks unexposed, P=.717), and lowest maximal vertical pocket before 24 weeks of gestation (0 cm exposed, 1.4 cm unexposed, P=.114) did not discriminate between survivors and nonsurvivors after exposure to prolonged preterm PROM. With antenatal steroid exposure and aggressive pulmonary management, survival to discharge after prolonged preterm PROM was 90%. Pulmonary morbidities were common. Of note, the data were limited to women who remained pregnant 1 week or longer after rupture of membranes.

  15. Prolonged heart xenograft survival using combined total lymphoid irradiation and cyclosporine

    International Nuclear Information System (INIS)

    Knechtle, S.J.; Halperin, E.C.; Saad, T.; Bollinger, R.R.

    1986-01-01

    Total lymphoid irradiation and cyclosporine have profound immunosuppressive properties and permit successful heart allotransplantation. Cyclosporine used alone has not permitted consistently successful transplantation between species in all cases. Total lymphoid irradiation has not been applied to xenotransplantation. The efficacy of total lymphoid irradiation alone and in combination with cyclosporine was examined using an animal model of heart xenotransplantation. Heterotopic heart transplants were performed using inbred Syrian hamsters as donors and Lewis rats as recipients. Total lymphoid irradiation was administered preoperatively over 3 weeks for a total dose of 15 gray. Cyclosporine was started on the day of surgery and was given as a daily intramuscular injection of 2.5, 5, or 10 mg/kg/day until rejection was complete. Neither total lymphoid irradiation nor cyclosporine alone markedly prolonged graft survival. However, combined total lymphoid irradiation and cyclosporine, 5 or 10 mg/kg/day, dramatically prolonged graft survival to greater than 100 days in most recipients. There were no treatment-related deaths. In conclusion, combined total lymphoid irradiation and cyclosporine permit successful long-term survival of heart xenotransplants in this hamster-to-rat model

  16. Survival without sequelae after prolonged cardiopulmonary resuscitation after electric shock.

    Science.gov (United States)

    Motawea, Mohamad; Al-Kenany, Al-Sayed; Hosny, Mostafa; Aglan, Omar; Samy, Mohamad; Al-Abd, Mohamed

    2016-03-01

    "Electrical shock is the physiological reaction or injury caused by electric current passing through the human body. It occurs upon contact of a human body part with any source of electricity that causes a sufficient current through the skin, muscles, or hair causing undesirable effects ranging from simple burns to death." Ventricular fibrillation is believed to be the most common cause of death after electrical shock. "The ideal duration of cardiac resuscitation is unknown. Typically prolonged cardiopulmonary resuscitation is associated with poor neurologic outcomes and reduced long term survival. No consensus statement has been made and traditionally efforts are usually terminated after 15-30 minutes." The case under discussion seems worthy of the somewhat detailed description given. It is for a young man who survived after 65 minutes after electrical shock (ES) after prolonged high-quality cardiopulmonary resuscitation (CPR), multiple defibrillations, and artificial ventilation without any sequelae. Early start of adequate chest compressions and close adherence to advanced cardiac life support protocols played a vital role in successful CPR.

  17. Survival in Patients Receiving Prolonged Ventilation: Factors that Influence Outcome

    Directory of Open Access Journals (Sweden)

    A. James Mamary

    2011-01-01

    Full Text Available Background Prolonged mechanical ventilation is increasingly common. It is expensive and associated with significant morbidity and mortality. Our objective is to comprehensively characterize patients admitted to a Ventilator Rehabilitation Unit (VRU for weaning and identify characteristics associated with survival. Methods 182 consecutive patients over 3.5 years admitted to Temple University Hospital (TUH VRU were characterized. Data were derived from comprehensive chart review and a prospectively collected computerized database. Survival was determined by hospital records and social security death index and mailed questionnaires. Results Upon admission to the VRU, patients were hypoalbuminemic (albumin 2.3 ± 0.6 g/dL, anemic (hemoglobin 9.6 ± 1.4 g/dL, with moderate severity of illness (APACHE II score 10.7 + 4.1, and multiple comorbidities (Charlson index 4.3 + 2.3. In-hospital mortality (19% was related to a higher Charlson Index score ( P = 0.006; OR 1.08-1.6, and APACHE II score ( P = 0.016; OR 1.03-1.29. In-hospital mortality was inversely related to admission albumin levels ( P = 0.023; OR 0.17-0.9. The presence of COPD as a comorbid illness or primary determinant of respiratory failure and higher VRU admission APACHE II score predicted higher long-term mortality. Conversely, higher VRU admission hemoglobin was associated with better long term survival (OR 0.57-0.90; P = 0.0006. Conclusion Patients receiving prolonged ventilation are hypoalbuminemic, anemic, have moderate severity of illness, and multiple comorbidities. Survival relates to these factors and the underlying illness precipitating respiratory failure, especially COPD.

  18. Significant prolongation of segmental pancreatic allograft survival in two species

    Energy Technology Data Exchange (ETDEWEB)

    Du Toit, D.F.; Heydenrych, J.J.

    1988-06-01

    A study was conducted to assess the suppression of segmental pancreatic allograft rejection by cyclosporine (CSA) alone in baboons and dogs, and subtotal marrow irradiation (TL1) alone and TL 1 in combination with CSA in baboons. Total pancreatectomy in the dog and primate provided a reliable diabetic model, induced an absolute deficiency of insulin and was uniformly lethal if not treated. Continuous administration of CSA in baboons resulted in modest allograft survival. As in baboons, dogs receiving CSA 25 mg/kg/d rendered moderate graft prolongation but a dose of 40 mg/kg/d resulted in significant graft survival (greater than 100 days) in 5 of 8 allograft recipients. Irradiation alone resulted in minimal baboon pancreatic allograft survival of 20 baboons receiving TL1 1,000 rad and CSA, 3 had graft survival greater than of 100 days. Of 15 baboons receiving TL1 800 rad and CSA, 6 had graft survival of greater than 100 days. In conclusion, CSA administration in dogs and TL1 in combination with CSA in baboons resulted in highly significant segmental pancreatic allograft survival.

  19. Significant prolongation of segmental pancreatic allograft survival in two species

    International Nuclear Information System (INIS)

    Du Toit, D.F.; Heydenrych, J.J.

    1988-01-01

    A study was conducted to assess the suppression of segmental pancreatic allograft rejection by cyclosporine (CSA) alone in baboons and dogs, and subtotal marrow irradiation (TL1) alone and TL 1 in combination with CSA in baboons. Total pancreatectomy in the dog and primate provided a reliable diabetic model, induced an absolute deficiency of insulin and was uniformly lethal if not treated. Continuous administration of CSA in baboons resulted in modest allograft survival. As in baboons, dogs receiving CSA 25 mg/kg/d rendered moderate graft prolongation but a dose of 40 mg/kg/d resulted in significant graft survival (greater than 100 days) in 5 of 8 allograft recipients. Irradiation alone resulted in minimal baboon pancreatic allograft survival of 20 baboons receiving TL1 1,000 rad and CSA, 3 had graft survival greater than of 100 days. Of 15 baboons receiving TL1 800 rad and CSA, 6 had graft survival of greater than 100 days. In conclusion, CSA administration in dogs and TL1 in combination with CSA in baboons resulted in highly significant segmental pancreatic allograft survival

  20. Branched-chain amino acid supplementation reduces oxidative stress and prolongs survival in rats with advanced liver cirrhosis.

    Directory of Open Access Journals (Sweden)

    Motoh Iwasa

    Full Text Available Long-term supplementation with branched-chain amino acids (BCAA is associated with prolonged survival and decreased frequency of development of hepatocellular carcinoma (HCC in patients with liver cirrhosis. However, the pharmaceutical mechanism underlying this association is still unclear. We investigated whether continuous BCAA supplementation increases survival rate of rats exposed to a fibrogenic agent and influences the iron accumulation, oxidative stress, fibrosis, and gluconeogenesis in the liver. Further, the effects of BCAA on gluconeogenesis in cultured cells were also investigated. A significant improvement in cumulative survival was observed in BCAA-supplemented rats with advanced cirrhosis compared to untreated rats with cirrhosis (P<0.05. The prolonged survival due to BCAA supplementation was associated with reduction of iron contents, reactive oxygen species production and attenuated fibrosis in the liver. In addition, BCAA ameliorated glucose metabolism by forkhead box protein O1 pathway in the liver. BCAA prolongs survival in cirrhotic rats and this was likely the consequences of reduced iron accumulation, oxidative stress and fibrosis and improved glucose metabolism in the liver.

  1. Effect of 34 kinds of traditional Japanese herbal medicines on prolongation of cardiac allograft survival.

    Science.gov (United States)

    Jin, X; Uchiyama, M; Zhang, Q; Harada, T; Otsuka, K; Shimokawa, T; Niimi, M

    2014-05-01

    Herbal medicines have been used for over 3,000 years in Asian as alternative therapy for their variety effects and have recently become popular in Europe and the United States. In the last 30 years, Japanese herbal medicines were widely used for treatment of diseases after been recognized officially by Japanese government. In this study, we investigated the effect of 34 kinds of traditional Japanese herbal medicines on alloimmune responses in a murine model of cardiac allograft transplantation. CBA mice (H2(k)) underwent transplantation of a C57BL/6 (H2(b)) heart and received oral administration of 2 g/kg/d of the 34 kinds of herbal medicines from the day of transplantation until 7 days afterward. Naïve CBA mice rejected B6 cardiac grafts acutely (median survival time [MST], 7 days). CBA transplant recipients given 2 g/kg/d of Sairei-to (TJ-114) and Tokishakuyaku-san (TJ-23) had prolonged C57BL/6 allograft survival indefinitely (both MSTs > 100 days). Moreover, CBA transplant recipients given Seisinrensiin (TJ-111), Tokishigyakukagoshuyushokyoto (TJ-38), Rikkunshito (TJ-43), Maobushisaishinto (TJ-127), Ninjin-yoei-to (TJ-108), Ryokan-kyomi-shinge-nin-to (TJ-119), Inchingorei-san (TJ-117), Hochuekkito (TJ-41), Kihi-to (TJ-65), and Sinbu-to (TJ-30) had also prolonged C57BL/6 allograft survival significantly (MSTs of 28, 22, 16, 14, 14, 13, 12, 9.5, 9 and 9 days, respectively). However, none of other 22 kinds of herbal medicines could prolong the allograft survival. Furthermore, oral administration of 2 g/kg/d of Daikenchuto (TJ-100) induced sudden death (within 1 minute) in CBA mice. In conclusion, 12 kinds of Japanese herbal medicines prolonged allograft survival and one showed toxic effect in mice. Copyright © 2014 Elsevier Inc. All rights reserved.

  2. Prolonged survival of a cat diagnosed with feline infectious peritonitis by immunohistochemistry.

    Science.gov (United States)

    Hugo, Timothy B; Heading, Kathryn L

    2015-01-01

    A 4-year-old, neutered male, British shorthair cat was presented with inappetence, vomiting, hyperproteinemia, and hyperglobulinemia. An exploratory celiotomy identified enlarged mesenteric lymph nodes. Immunohistochemistry of lymph node biopsies confirmed feline infectious peritonitis. This patient had a prolonged survival of 787 d after initial presentation.

  3. Prolonged PR interval predicts clinical recurrence of atrial fibrillation after catheter ablation.

    Science.gov (United States)

    Park, Junbeom; Kim, Tae-Hoon; Lee, Jihei Sara; Park, Jin Kyu; Uhm, Jae Sun; Joung, Boyoung; Lee, Moon Hyoung; Pak, Hui-Nam

    2014-10-07

    A prolonged PR interval is known to be a poor prognostic factor in cardiovascular disease. The aim of this study was to investigate the association between PR interval and clinical outcome in patients undergoing radiofrequency catheter ablation (RFCA) of atrial fibrillation (AF). We prospectively included 576 patients with AF (75.5% male, 57.8±11.6 years old, 68.8% paroxysmal AF) who underwent RFCA. We analyzed preprocedural sinus rhythm ECGs obtained in the absence of antiarrhythmic drug, and all enrolled patients were categorized into 4 groups based on the quartile values of the PR interval (166, 182, and 202 ms), and were analyzed according to the left atrium (LA) volume (CT; Computed tomography), LA voltage (NavX), and clinical outcome of AF ablation. Based on quartile value of PR interval, the highest quartile of PR interval (Q4; PR ≥202 ms) was oldest (PPR interval was a significant predictor of AF recurrence after RFCA of AF (HR=1.969, 95% CI 1.343 to 2.886, P=0.001). The PR interval was closely associated with advanced LA remodeling due to AF, and had a noninvasive significant predictive value of clinical recurrence of AF after RFCA. © 2014 The Authors. Published on behalf of the American Heart Association, Inc., by Wiley Blackwell.

  4. Catheter visualisation in MR tomography: first animal experimental experiences with field inhomogeneity catheters

    International Nuclear Information System (INIS)

    Adam, G.; Glowinski, A.; Neuerburg, J.; Buecker, A.; Vaals, J.J. van; Hurtak, W.; Guenther, R.W.

    1997-01-01

    Purpose: To assess the feasibility of a new developed field inhomogeneity catheter for interventional MR imaging in vivo. Materials and methods: Three different prototypes of a field inhomogeneity catheter were investigated in 6 pigs. The catheters were introduced in Seldinger technique via the femoral vessels over a guide wire on an interventional MR system (Philips Gyroscan NT combined with a C-arm fluoroscopy unit [Philips BV 212[). Catheters were placed in veins and arteries. The catheter position was controlled by a fast gradient echo sequence (Turbo Field Echo [TEF[). Results: Catheters were introduced over a guide wire without complications in all cases. Using the field inhomogeneity concept, catheters were easily visualised in the inferior vena cava and the aorta by the fast gradient echo technique on MR in all cases. Although aortic branches were successfully cannulated, the catheters were not displayed by the TFE technique due to the complex and tortuous anatomy. All animals survived the experiments without complications. Conclusion: MR guided visualisation of a field inhomogeneity catheter is a simple concept which can be realised on each MR scanner and may allow intravascular MR guided interventions in future. (orig.) [de

  5. The Impact of Tunneled Catheters for Ascites and Peritoneal Carcinomatosis on Patient Rehospitalizations

    International Nuclear Information System (INIS)

    Qu, Chuanxing; Xing, Minzhi; Ghodadra, Anish; McCluskey, Kevin M.; Santos, Ernesto; Kim, Hyun S.

    2016-01-01

    PurposeThe aim of the study is to assess patient outcomes, complications, impact on rehospitalizations, and healthcare costs in patients with malignant ascites treated with tunneled catheters.Materials and MethodsA total of 84 patients with malignant ascites (mean age, 60 years) were treated with tunneled catheters. Patients with peritoneal carcinomatosis and malignant ascites treated with tunneled drain catheter placement over a 3-year period were studied. Overall survival from the time of ascites and catheter placement were stratified by primary cancer and analyzed using the Kaplan–Meier method. Complications were graded by the Common Terminology Criteria for Adverse Events v3.0 (CTCAE). The differences between pre- and post-catheter admissions, hospitalizations, and Emergency Department (ED) visits, as well as related inpatient expenses were compared using paired t tests.ResultsThere were no significant differences in gender, age, or race between different primary cancer subgroups. One patient (1 %) developed bleeding (CTCAE-2). Four patients (5 %) developed local cellulitis (CTCAE-2). Three patients (4 %) had prolonged hospital stay (between 7 and 10 days) to manage ascites-related complications such as abdominal distention, discomfort, or pain. Comparison between pre- and post-catheter hospitalizations showed significantly lower admissions (−1.4/month, p < 0.001), hospital stays (−4.2/month, p = 0.003), and ED visits (−0.9/month, p = 0.002). The pre- and post-catheter treatment health care cost was estimated using MS-DRG IPPS payment system and it demonstrated significant cost savings from decreased inpatient admissions in post-treatment period (−$9535/month, p < 0.001).ConclusionsTunneled catheter treatment of malignant ascites is safe, feasible, well tolerated, and cost effective. Tunneled catheter treatment may play an important role in improving patients’ quality of life and outcomes while controlling health care expenditures.

  6. The Impact of Tunneled Catheters for Ascites and Peritoneal Carcinomatosis on Patient Rehospitalizations

    Energy Technology Data Exchange (ETDEWEB)

    Qu, Chuanxing [University of Pittsburgh School of Medicine, Division of Interventional Radiology, Department of Radiology (United States); Xing, Minzhi [Yale University School of Medicine, Division of Interventional Radiology, Department of Radiology and Biomedical Imaging, Yale Cancer Center (United States); Ghodadra, Anish; McCluskey, Kevin M.; Santos, Ernesto; Kim, Hyun S., E-mail: kevin.kim@yale.edu [University of Pittsburgh School of Medicine, Division of Interventional Radiology, Department of Radiology (United States)

    2016-05-15

    PurposeThe aim of the study is to assess patient outcomes, complications, impact on rehospitalizations, and healthcare costs in patients with malignant ascites treated with tunneled catheters.Materials and MethodsA total of 84 patients with malignant ascites (mean age, 60 years) were treated with tunneled catheters. Patients with peritoneal carcinomatosis and malignant ascites treated with tunneled drain catheter placement over a 3-year period were studied. Overall survival from the time of ascites and catheter placement were stratified by primary cancer and analyzed using the Kaplan–Meier method. Complications were graded by the Common Terminology Criteria for Adverse Events v3.0 (CTCAE). The differences between pre- and post-catheter admissions, hospitalizations, and Emergency Department (ED) visits, as well as related inpatient expenses were compared using paired t tests.ResultsThere were no significant differences in gender, age, or race between different primary cancer subgroups. One patient (1 %) developed bleeding (CTCAE-2). Four patients (5 %) developed local cellulitis (CTCAE-2). Three patients (4 %) had prolonged hospital stay (between 7 and 10 days) to manage ascites-related complications such as abdominal distention, discomfort, or pain. Comparison between pre- and post-catheter hospitalizations showed significantly lower admissions (−1.4/month, p < 0.001), hospital stays (−4.2/month, p = 0.003), and ED visits (−0.9/month, p = 0.002). The pre- and post-catheter treatment health care cost was estimated using MS-DRG IPPS payment system and it demonstrated significant cost savings from decreased inpatient admissions in post-treatment period (−$9535/month, p < 0.001).ConclusionsTunneled catheter treatment of malignant ascites is safe, feasible, well tolerated, and cost effective. Tunneled catheter treatment may play an important role in improving patients’ quality of life and outcomes while controlling health care expenditures.

  7. Radiofrequency catheter oblation in atrial flutter

    International Nuclear Information System (INIS)

    Yan Ji; Wang Heping; Xu Jian; Liu Fuyuan; Fan Xizhen; An Chunsheng; Han Xiaoping; Ding Xiaomei; Wang Jiasheng; Gu Tongyuan

    2002-01-01

    Objective: To evaluate the radiofrequency catheter ablation for type I atrial flutter through application of Holo catheter labelling with anatomic imaging localization to ablate the isthmus of IVCTA during complete double-way block. Methods: Eleven cases with type I atrial flutter undergone Holo catheter labelling technique and consecution with conduction time change of coronary venous sinus orifice with-right atrial lower lateral wall pace excitation, were performed with radiofrequency catheter ablation for the isthmus outcoming with complete double-way conduction block. Results: All together 11 cases with 4 of atrial flutter and 7 of sinus rhythm were undergone radiofrequency catheter ablation resulting with double-way conduction block of the isthmus accompanied by prolongation of right atrial conduction time 56.0 ± 2.3 ms and 53.0 ± 4.6 ms respectively. The right atrial excitation appeared to be in clockwise and counter-clockwise of single direction. No recurrence occurred during 3-34 months follow up with only one showing atrial fibrillation. Conclusions: The application of Holo catheter labelling technique with anatomic imaging localization to achieve the double-way conduction block by radiofrequency catheter ablation of TVC-TA isthmus, is a reliable method for treating atrial flutter

  8. Hyperacute stroke patients and catheter thrombolysis therapy. Correlation between computed tomography perfusion maps and final infarction

    International Nuclear Information System (INIS)

    Naito, Yukari; Tanaka, Shigeko; Inoue, Yuichi; Ota, Shinsuke; Sakaki, Saburo; Kitagaki, Hajime

    2008-01-01

    We investigated the correlation between abnormal perfusion areas by computed tomography perfusion (CTP) study of hyperacute stroke patients and the final infarction areas after intraarterial catheter thrombolysis. CTP study using the box-modulation transfer function (box-MTF) method based on the deconvolution analysis method was performed in 22 hyperacute stroke patients. Ischemic lesions were immediately treated with catheter thrombolysis after CTP study. Among them, nine patients with middle cerebral artery (MCA) occlusion were investigated regarding correlations of the size of the prolonged mean transit time (MTT) area, the decreased cerebral blood volume (CBV) area, and the final infarction area. Using the box-MTF method, the prolonged MTT area was almost identical to the final infarction area in the case of catheter thrombolysis failure. The decreased CBV areas resulted in infarction or hemorrhage, irrespective of the outcome of recanalization after catheter thrombolysis. The prolonged MTT areas, detected by the box-MTF method of CTP in hyperacute stroke patients, included the area of true prolonged MTT and the tracer delay. The prolonged MTT area was almost identical to the final infarction area when recanalization failed. We believe that a tracer delay area also indicates infarction in cases of thrombolysis failure. (author)

  9. Successful treatment of massive pulmonary embolism with prolonged catheter-directed thrombolysis.

    LENUS (Irish Health Repository)

    Kelly, Peter

    2012-02-03

    This is a case report of a young woman who presented with an extensive pulmonary embolism and echocardiographic evidence of right ventricular dysfunction. Although hemodynamically stable, the patient\\'s clinical condition failed to improve with standard heparin anticoagulation. Successful local catheter-directed thrombolysis was performed over an extended period of 48 h with regular monitoring of response to therapy by computed tomography-pulmonary angiography and echocardiography. To our knowledge, treatment of a pulmonary embolism by catheter-directed thrombolytic infusion over an extended period of 48 h has not previously been described.

  10. Pretransplant portal venous administration of donor antigen and portal venous allograft drainage synergistically prolong rat cardiac allograft survival

    International Nuclear Information System (INIS)

    Kamei, T.; Callery, M.P.; Flye, M.W.

    1990-01-01

    The effect of antigen given through the portal vein (PV) before transplantation or continuous drainage of a graft into the PV results in moderate prolongation of allograft survival. This study examines these treatment modalities further. Pretransplant donor antigen as 25 x 10(6) ultraviolet B-irradiated (12,000 joules/m2) donor spleen cells was given 7 days before heart transplantation through either the PV or systemic venous (IV) routes. On day 0, Lewis-to-Buffalo rat cardiac allografts were drained either into the PV or IV. Pretransplant PV donor antigen administration (p less than 0.005), but not by IV administration, significantly prolonged cardiac allograft survival across the strong RT 1 rat histoincompatibility barrier. Similarly PV, but not IV, drainage of the graft prolonged graft survival (p less than 0.005). Pretransplant IV antigen administration had no additive effect on PV drainage graft survival. In contrast, when pretransplant PV donor antigen was combined with PV drainage, 11 of 14 allografts (p less than 0.001) continued to function, free of rejection, after 150 days. Therefore for rat cardiac transplants a clearly synergistic graft-prolonging effect results when pretransplant PV donor antigen is combined with PV drainage of the allografts. These data clarify the potent tolerogenic effects of alloantigen not only administered into the PV but also continuously shed intraportally so that it is first processed by the liver

  11. Heparin for prolonging peripheral intravenous catheter use in neonates: a randomized controlled trial.

    Science.gov (United States)

    Upadhyay, A; Verma, K K; Lal, P; Chawla, D; Sreenivas, V

    2015-04-01

    To determine the efficacy of heparinized saline administered as intermittent flush on functional duration of the peripheral intravenous catheter (PIVC) in neonates. Randomized, double-blind and placebo-controlled trial. Neonatal intensive care unit of a teaching hospital. Term and preterm neonates born at >32 weeks of gestation who required PIVC only for intermittent administration of antibiotics. Eligible neonates were randomized to receive 1 ml of either heparinized saline (10 U ml(-1)) (n=60) or normal saline (n=60) every 12 h before and after intravenous antibiotics. Functional duration of first peripheral intravenous catheter. A total of 120 neonates were randomized to two groups of 60 neonates each. The mean (s.d.) of age of babies in case and control group was 5.7 (2.5) days and 4.6 (3.1) days, respectively. The average weight of babies in both the groups was 2.1 kg. Mean functional duration of first catheter was more in heparinized saline group, mean (s.d.) of 71.68 h  (27.3) as compared with 57.7 h (23.6) in normal saline group (P<0.005). The mean (95% confidence interval) difference in functional duration in the two groups was 13.9 h (4.7-23.15). Mean duration of patency for any catheter was also significantly more in heparinized saline group than control group. Heparinized saline flush increases the functional duration of peripheral intravenous catheter.

  12. Branched-Chain Amino Acid Supplementation Reduces Oxidative Stress and Prolongs Survival in Rats with Advanced Liver Cirrhosis

    Science.gov (United States)

    Mifuji-Moroka, Rumi; Hara, Nagisa; Miyachi, Hirohide; Sugimoto, Ryosuke; Tanaka, Hideaki; Fujita, Naoki; Gabazza, Esteban C.; Takei, Yoshiyuki

    2013-01-01

    Long-term supplementation with branched-chain amino acids (BCAA) is associated with prolonged survival and decreased frequency of development of hepatocellular carcinoma (HCC) in patients with liver cirrhosis. However, the pharmaceutical mechanism underlying this association is still unclear. We investigated whether continuous BCAA supplementation increases survival rate of rats exposed to a fibrogenic agent and influences the iron accumulation, oxidative stress, fibrosis, and gluconeogenesis in the liver. Further, the effects of BCAA on gluconeogenesis in cultured cells were also investigated. A significant improvement in cumulative survival was observed in BCAA-supplemented rats with advanced cirrhosis compared to untreated rats with cirrhosis (PBCAA supplementation was associated with reduction of iron contents, reactive oxygen species production and attenuated fibrosis in the liver. In addition, BCAA ameliorated glucose metabolism by forkhead box protein O1 pathway in the liver. BCAA prolongs survival in cirrhotic rats and this was likely the consequences of reduced iron accumulation, oxidative stress and fibrosis and improved glucose metabolism in the liver. PMID:23936183

  13. Supra-complete surgery via dual intraoperative visualization approach (DiVA) prolongs patient survival in glioblastoma.

    Science.gov (United States)

    Eyüpoglu, Ilker Y; Hore, Nirjhar; Merkel, Andreas; Buslei, Rolf; Buchfelder, Michael; Savaskan, Nicolai

    2016-05-03

    Safe and complete resection represents the first step in the treatment of glioblastomas and is mandatory in increasing the effectiveness of adjuvant therapy to prolong overall survival. With gross total resection currently limited in extent to MRI contrast enhancing areas, the extent to which supra-complete resection beyond obvious contrast enhancement could have impact on overall survival remains unclear. DiVA (dual intraoperative visualization approach) redefines gross total resection as currently accepted by enabling for the first time supra-complete surgery without compromising patient safety. This approach exploits the advantages of two already accepted surgical techniques combining intraoperative MRI with integrated functional neuronavigation and 5-ALA by integrating them into a single surgical approach. We investigated whether this technique has impact on overall outcome in GBM patients. 105 patients with GBM were included. We achieved complete resection with intraoperative MRI alone according to current best-practice in glioma surgery in 75 patients. 30 patients received surgery with supra-complete resection. The control arm showed a median life expectancy of 14 months, reflecting current standards-of-care and outcome. In contrast, patients receiving supra-complete surgery displayed significant increase in median survival time to 18.5 months with overall survival time correlating directly with extent of supra-complete resection. This extension of overall survival did not come at the cost of neurological deterioration. We show for the first time that supra-complete glioma surgery leads to significant prolongation of overall survival time in GBM patients.

  14. Prolongation of rat islet allograft survival by direct ultraviolet irradiation of the graft

    International Nuclear Information System (INIS)

    Lau, H.; Reemtsma, K.; Hardy, M.A.

    1984-01-01

    Ultraviolet irradiation of rat dendritic cells completely abrogated their allostimulatory capacity in a mixed lymphocyte reaction. Rat islets of Langerhans similarly irradiated remained hormonally functional when transplanted into syngeneic diabetic rats. Allogeneic transplantation across a major histocompatibility barrier of islets initially treated in vitro with ultraviolet irradiation resulted in prolonged allograft survival without the use of any immunosuppressive agents

  15. Radiologic Placement of Tunneled Central Venous Catheters in Pediatric Patients

    International Nuclear Information System (INIS)

    Kim, Eun Ji; Song, Soon Young; Cho, On Koo; Koh, Byung Hee; Kim, Yong Soo; Jeong, Woo Kyoung; Lee, Yong Ho

    2010-01-01

    We evaluated the technical success and complication rates associated with the radiological placement of tunneled central venous catheters in pediatric patients. Between May 1, 2005 and March 31, 2008, a total of 46 tunneled central venous catheters were placed in 34 children (M:F = 22:12; mean age, 9.9 years [9 months to 16.8 years]). All procedures were performed under ultrasonographic and fluoroscopic guidance. Follow-up data were obtained through the retrospective review of the medical records. We used the Kaplan-Meier survival method for the evaluation of survival rate of the catheters. All procedures were technically successful. The observed periprocedural complications included hematoma formation in three patients. The mean catheter life was 189.3 days (total, 8710 days; range, 7-810). Catheters were removed due to death (n=9), the end of treatment (n=8), catheter sepsis (n=4), malfunction (n=8), and accidental removal (n=4). The rate of catheter sepsis and malfunction was 0.459 and 0.919 for every 1000 catheter days, respectively. The expected mean catheter life was 479.6 days as per the Kaplan- Meier analysis. The results suggest that the radiologic placement of a tunneled central venous catheter is an effective technique with a high technical success rate and low complication rate

  16. Radiologic Placement of Tunneled Central Venous Catheters in Pediatric Patients

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Eun Ji; Song, Soon Young; Cho, On Koo; Koh, Byung Hee; Kim, Yong Soo; Jeong, Woo Kyoung; Lee, Yong Ho [Hanyang University College of Medicine, Seoul (Korea, Republic of)

    2010-08-15

    We evaluated the technical success and complication rates associated with the radiological placement of tunneled central venous catheters in pediatric patients. Between May 1, 2005 and March 31, 2008, a total of 46 tunneled central venous catheters were placed in 34 children (M:F = 22:12; mean age, 9.9 years [9 months to 16.8 years]). All procedures were performed under ultrasonographic and fluoroscopic guidance. Follow-up data were obtained through the retrospective review of the medical records. We used the Kaplan-Meier survival method for the evaluation of survival rate of the catheters. All procedures were technically successful. The observed periprocedural complications included hematoma formation in three patients. The mean catheter life was 189.3 days (total, 8710 days; range, 7-810). Catheters were removed due to death (n=9), the end of treatment (n=8), catheter sepsis (n=4), malfunction (n=8), and accidental removal (n=4). The rate of catheter sepsis and malfunction was 0.459 and 0.919 for every 1000 catheter days, respectively. The expected mean catheter life was 479.6 days as per the Kaplan- Meier analysis. The results suggest that the radiologic placement of a tunneled central venous catheter is an effective technique with a high technical success rate and low complication rate.

  17. Solid-state vs water-perfused catheters to measure colonic high-amplitude propagating contractions

    NARCIS (Netherlands)

    Liem, O.; Burgers, R. E.; Connor, F. L.; Benninga, M. A.; Reddy, S. N.; Mousa, H. M.; Di Lorenzo, C.

    2012-01-01

    Background Solid-state (SS) manometry catheters with portable data loggers offer many potential advantages over traditional water-perfused (WP) systems, such as prolonged recordings in a more physiologic ambulatory setting and the lack of risk for water overload. The use of SS catheters has not been

  18. Systematic review and meta-analysis: reminder systems to reduce catheter-associated urinary tract infections and urinary catheter use in hospitalized patients.

    Science.gov (United States)

    Meddings, Jennifer; Rogers, Mary A M; Macy, Michelle; Saint, Sanjay

    2010-09-01

    Prolonged catheterization is the primary risk factor for catheter-associated urinary tract infection (CAUTI). Reminder systems are interventions used to prompt the removal of unnecessary urinary catheters. To summarize the effect of urinary catheter reminder systems on the rate of CAUTI, urinary catheter use, and the need for recatheterization, we performed a systematic review and meta-analysis. Studies were identified in MEDLINE, the Cochrane Library, Biosis, the Web of Science, EMBASE, and CINAHL through August 2008. Only interventional studies that used reminders to physicians or nurses that a urinary catheter was in use or stop orders to prompt catheter removal in hospitalized adults were included. A total of 6679 citations were identified; 118 articles were reviewed, and 14 articles met the selection criteria. The rate of CAUTI (episodes per 1000 catheter-days) was reduced by 52% (P SMD) in the duration of catheterization was -1.11 overall (P = 070), including a statistically significant decrease in studies that used a stop order (SMD, -0.30; P = .001) but not in those that used a reminder (SMD, -1.54; P = .071). Recatheterization rates were similar in control and intervention groups. Urinary catheter reminders and stop orders appear to reduce the rate of CAUTI and should be strongly considered to enhance the safety of hospitalized patients.

  19. Prolonged survival of isolated rat islet allografts pre-irradiated with X-rays

    Energy Technology Data Exchange (ETDEWEB)

    Kimura, Toshihisa; Note, Masayuki; Nakagawara, Gizo (Fukui Medical School, Matsuoka (Japan)); Kojima, Yasuhiko

    1994-04-01

    Prior to transplantation of islets, pre-incubation, or pre-irradiation may suppress the immunogenicity of islet cells without suppressing islet function. In the presently described experiments we investigated the use of X-ray irradiation prior to transplantation to reduce islet immunogenicity. To determine whether or not the islet function was reduced after irradiation, ACI rat islets were transplanted into the subrenal capsules of isogeneic rats which had been diabetic and examined the blood glucose level over a period of 40 days. The results indicated that irradiation injury was dose-dependent and that islets irradiated with over 80 Gy lost their function. Next, allogeneic transplantation was performed using the model of ACI rats to Lewis rats without the use of any immunosuppressive agent. Non-irradiated islets were rejected within 7 days. However 20 Gy or 40 Gy irradiated islets prolonged survival (18.7[+-]5.8 days (n=6) and 26.7[+-]10.0 days (n=6), respectively). To determine the basis for this effect, MHC expression of islets was examined by the immunoperoxidase technique. Immunohistologic studies showed that 40 Gy-irradiated islets were depleted of Class II antigen positive cells while Class I antigen expression was unchanged. These results suggest that the prolongation of islets survival by X-ray irradiation may possibly be due to, in part, the depletion of donor Class II antigen positive cells. (author).

  20. Ultraviolet light immunomodulation of canine islets for prolongation of allograft survival

    International Nuclear Information System (INIS)

    Kenyon, N.S.; Strasser, S.; Alejandro, R.

    1990-01-01

    Ultraviolet (UV) light treatment of donor islets has been shown to be effective for the prolongation of islet allograft survival in rodent models. This study evaluated UV as an immunomodulator of canine islets. The effects of UV irradiation on islet secretory function in vitro revealed a trend of increasing basal insulin release with increasing doses of UV and a corresponding significant decrease in glucose-mediated insulin release (expressed as percentage of basal fractional insulin release) beginning at UV light exposures of 200-300 J/m2 (n = 3, P less than 0.05). Proliferative responses to UV-irradiated allogeneic peripheral blood leukocytes and islets were significantly decreased by 53-112% (P less than 0.05) in 27 of 29 mixed-lymphocyte cultures and by 35-74% (P less than 0.05) in 4 of 5 mixed-lymphocyte islet culture experiments, respectively, beginning at 200-600 J/m2. Autotransplantation of nonirradiated (n = 8) and irradiated islets (600 J/m2, n = 6) resulted in a 1-mo graft survival rate of 75% for the control group and 50% for the irradiated group. Allotransplantation of irradiated islets (600 J/m2) into either nonimmunosuppressed recipients (1 donor to 1 recipient, n = 8) or recipients of subimmunosuppressive doses of cyclosporin (2 donors to 1 recipient, n = 4) resulted in 100% rejection by day 10. In contrast, when islets were cultured for 24 h postirradiation and transplanted into cyclosporin-treated pancreatectomized recipients (2 donors to 1 recipient), 3 of 7 grafts were prolonged beyond day 10 to days 16, 26, and greater than 100

  1. Synbiotic approach restores intestinal homeostasis and prolongs survival in leukaemic mice with cachexia.

    Science.gov (United States)

    Bindels, Laure B; Neyrinck, Audrey M; Claus, Sandrine P; Le Roy, Caroline I; Grangette, Corinne; Pot, Bruno; Martinez, Inés; Walter, Jens; Cani, Patrice D; Delzenne, Nathalie M

    2016-06-01

    Cancer cachexia is a multifactorial syndrome that includes muscle wasting and inflammation. As gut microbes influence host immunity and metabolism, we investigated the role of the gut microbiota in the therapeutic management of cancer and associated cachexia. A community-wide analysis of the caecal microbiome in two mouse models of cancer cachexia (acute leukaemia or subcutaneous transplantation of colon cancer cells) identified common microbial signatures, including decreased Lactobacillus spp. and increased Enterobacteriaceae and Parabacteroides goldsteinii/ASF 519. Building on this information, we administered a synbiotic containing inulin-type fructans and live Lactobacillus reuteri 100-23 to leukaemic mice. This treatment restored the Lactobacillus population and reduced the Enterobacteriaceae levels. It also reduced hepatic cancer cell proliferation, muscle wasting and morbidity, and prolonged survival. Administration of the synbiotic was associated with restoration of the expression of antimicrobial proteins controlling intestinal barrier function and gut immunity markers, but did not impact the portal metabolomics imprinting of energy demand. In summary, this study provided evidence that the development of cancer outside the gut can impact intestinal homeostasis and the gut microbial ecosystem and that a synbiotic intervention, by targeting some alterations of the gut microbiota, confers benefits to the host, prolonging survival and reducing cancer proliferation and cachexia.

  2. Reinnervation following catheter-based radio-frequency renal denervation.

    Science.gov (United States)

    Booth, Lindsea C; Nishi, Erika E; Yao, Song T; Ramchandra, Rohit; Lambert, Gavin W; Schlaich, Markus P; May, Clive N

    2015-04-20

    What is the topic of this review? Does catheter-based renal denervation effectively denervate the afferent and efferent renal nerves and does reinnervation occur? What advances does it highlight? Following catheter-based renal denervation, the afferent and efferent responses to electrical stimulation were abolished, renal sympathetic nerve activity was absent, and levels of renal noradrenaline and immunohistochemistry for tyrosine hydroxylase and calcitonin gene-related peptide were significantly reduced. By 11 months after renal denervation, both the functional responses and anatomical markers of afferent and efferent renal nerves had returned to normal, indicating reinnervation. Renal denervation reduces blood pressure in animals with experimental hypertension and, recently, catheter-based renal denervation was shown to cause a prolonged decrease in blood pressure in patients with resistant hypertension. The randomized, sham-controlled Symplicity HTN-3 trial failed to meet its primary efficacy end-point, but there is evidence that renal denervation was incomplete in many patients. Currently, there is little information regarding the effectiveness of catheter-based renal denervation and the extent of reinnervation. We assessed the effectiveness of renal nerve denervation with the Symplicity Flex catheter and the functional and anatomical reinnervation at 5.5 and 11 months postdenervation. In anaesthetized, non-denervated sheep, there was a high level of renal sympathetic nerve activity, and electrical stimulation of the renal nerve increased blood pressure and reduced heart rate (afferent response) and caused renal vasoconstriction and reduced renal blood flow (efferent response). Immediately after renal denervation, renal sympathetic nerve activity and the responses to electrical stimulation were absent, indicating effective denervation. By 11 months after denervation, renal sympathetic nerve activity was present and the responses to electrical stimulation

  3. Prebiotics enhance survival and prolong the retention period of specific probiotic inocula in an in vivo murine model.

    Science.gov (United States)

    Su, P; Henriksson, A; Mitchell, H

    2007-12-01

    To identify novel prebiotics that could be used to maintain persistence of three representative probiotic strains in vivo. Test mice were treated with prebiotics soybean oligosaccharide (SOS), fructooligosaccharide (FOS) or inulin, followed by probiotics Lactobacillus acidophilus LAFTI L10 (L10), Bifidobacterium lactis LAFTI B94 (B94) or Lactobacillus casei L26 LAFTI (L26). Faecal samples were then collected and analysed using selective medium and PCR analysis to determine the presence of the probiotic strains. In contrast to the control groups, in mice fed prebiotics, the survival and retention time of the test probiotics was increased extensively. SOS and FOS prolonged the retention period of L10 from 24 to 30 h. Of the three prebiotics, FOS gave the best result with B94, prolonging the retention period from 3 to > or =10 days. Of the three prebiotics, inulin gave the best result for L26, prolonging the retention period from 2 to > or =6 days. The prebiotics SOS, FOS and inulin significantly enhance survival and prolong the retention period of L10, B94 and L26 in vivo. Our results demonstrate the potential use of FOS, inulin and SOS as prebiotics in conjunction with the probiotic strains L10, B94 and L26 for new synbiotic products.

  4. Two years experience with tunneled dialysis catheters in patients requiring haemodialysis

    International Nuclear Information System (INIS)

    Raheem, A.; Rana, A. I.; Ramzan, M.; Shah, R. A.; Mehmood, S. N.; Naseem, S.

    2014-01-01

    Objective: To look for survival rate and major reasons behind the failure of tunnelled dialysis catheters in patients on haemodialysis. Methods: The retrospective study was conducted at the Department of Interventional Radiology, Shifa International Hospital, Islamabad, and comprised records of 100 consecutive subjects from a list of patients in whom tunnelled cuffed catheters were placed from February 2009 to January 2011 and were followed up for two years. Data was collected on a proforma from the hospital database and medical records of patients. SPSS 19 was used for statistical analysis. Results: Of the total 122 catheters placed in 100 patients, 49(40.16%) were lost to follow-up. Of the remaining 73(59.83%) catheters, 38(52%) had achieved their desired function, while 35(48%) failed to achieve the target duration. Among the reasons of catheter failure, infection was the commonest at 13(37.14%) with infection rate of 0.24 per 1000 catheter days. According to Kaplan Meier analysis, catheter survival rates at 60, 90 and 180 days were 89%, 77% and 64% respectively. Mean effective duration of catheter was 129+-117 days. Conclusion: Tunnelled dialysis catheters can be safely used as vascular access till the maturation of fistula and may be an alternative to Arterio-Venous Fistula or graft for long-term vascular access if indicated. (author)

  5. Reduction of exit-site infections of tunnelled intravascular catheters among neutropenic patients by sustained-release chlorhexidine dressings: results from a prospective randomized controlled trial.

    Science.gov (United States)

    Chambers, S T; Sanders, J; Patton, W N; Ganly, P; Birch, M; Crump, J A; Spearing, R L

    2005-09-01

    Exit-site and tunnel infections of tunnelled central intravascular catheters are a frequent source of morbidity among neutropenic patients and may necessitate catheter removal. They require antimicrobial therapy that increases healthcare costs and is associated with adverse drug reactions. A prospective randomized clinical trial was conducted among adult patients undergoing chemotherapy in a haematology unit. Tunnelled intravascular catheters were randomized to receive the control of a standard dressing regimen as recommended by the British Committee for Standards in Haematology, or to receive the intervention of a sustained-release chlorhexidine dressing. Follow-up data were available in 112 of 114 tunnelled intravascular catheters which were randomized. Exit-site or combined exit-site/tunnel infections occurred in 23 (43%) of 54 catheters in the control group, and five (9%) of 58 catheters in the intervention group [odds ratio (OR) for intervention group compared with control group =0.13, 95% confidence intervals (CI) 0.04-0.37, P<0.001]. More tunnelled intravascular catheters were prematurely removed from the control group than the intervention group for documented infections [20/54 (37%) vs 6/58 (10%), OR=0.20, 95%CI 0.53-0.07]. However, there was no difference in the numbers of tunnelled intravascular catheters removed for all proven and suspected intravascular catheter-related infections [21/54 (39%) vs 19/58 (33%)], or in the time to removal of catheters for any reason other than death or end of treatment for underlying disease. Thus chlorhexidine dressings reduced the incidence of exit-site/tunnel infections of indwelling tunnelled intravascular catheters without prolonging catheter survival in neutropenic patients, and could be considered as part of the routine management of indwelling tunnelled intravascular catheters among neutropenic patients.

  6. The driver and passenger effects of isocitrate dehydrogenase 1 and 2 mutations in oncogenesis and survival prolongation.

    Science.gov (United States)

    Molenaar, Remco J; Radivoyevitch, Tomas; Maciejewski, Jaroslaw P; van Noorden, Cornelis J F; Bleeker, Fonnet E

    2014-12-01

    Mutations in isocitrate dehydrogenase 1 and 2 (IDH1 and IDH2) are key events in the development of glioma, acute myeloid leukemia (AML), chondrosarcoma, intrahepatic cholangiocarcinoma (ICC), and angioimmunoblastic T-cell lymphoma. They also cause D-2-hydroxyglutaric aciduria and Ollier and Maffucci syndromes. IDH1/2 mutations are associated with prolonged survival in glioma and in ICC, but not in AML. The reason for this is unknown. In their wild-type forms, IDH1 and IDH2 convert isocitrate and NADP(+) to α-ketoglutarate (αKG) and NADPH. Missense mutations in the active sites of these enzymes induce a neo-enzymatic reaction wherein NADPH reduces αKG to D-2-hydroxyglutarate (D-2HG). The resulting D-2HG accumulation leads to hypoxia-inducible factor 1α degradation, and changes in epigenetics and extracellular matrix homeostasis. Such mutations also imply less NADPH production capacity. Each of these effects could play a role in cancer formation. Here, we provide an overview of the literature and discuss which downstream molecular effects are likely to be the drivers of the oncogenic and survival-prolonging properties of IDH1/2 mutations. We discuss interactions between mutant IDH1/2 inhibitors and conventional therapies. Understanding of the biochemical consequences of IDH1/2 mutations in oncogenesis and survival prolongation will yield valuable information for rational therapy design: it will tell us which oncogenic processes should be blocked and which "survivalogenic" effects should be retained. Copyright © 2014 Elsevier B.V. All rights reserved.

  7. Severe Juxtahepatic Venous Injury: Survival after Prolonged Hepatic Vascular Isolation Without Shunting

    Directory of Open Access Journals (Sweden)

    J. E. J. Krige

    1990-01-01

    Full Text Available Survival following major juxtahepatic venous injury is rare in blunt liver trauma despite the use of intracaval shunting. Prolonged liver arterial inflow control, total hepatic venous isolation and lobectomy without shunting was used in a patient to repair a combined vena caval and hepatic venous injury after blunt liver injury. An extended period of normothermic hepatic ischemia was tolerated. Early recognition of retrohepatic venous injury and temporary liver packing to control bleeding and correct hypovolemia are essential before caval occlusion. Hepatic vascular isolation without shunting is an effective simple alternative technique allowing major venous repair in complex liver trauma.

  8. Radiologically placed tunneled peritoneal catheter in palliation of malignant ascites

    International Nuclear Information System (INIS)

    Akinci, Devrim; Erol, Bekir; Ciftci, Tuerkmen T.; Akhan, Okan

    2011-01-01

    The purpose of this study was to evaluate retrospectively the safety and effectiveness of radiologically placed tunneled peritoneal catheter in palliation of malignant ascites. Between July 2005 and June 2009, 41 tunneled peritoneal catheters were placed under ultrasonographic and fluoroscopic guidance in 40 patients (mean age, 55 years; 22 women) who had symptomatic malignant ascites. No procedure related mortality was observed. Major complication occurred in one patient (2.5%) in the form of serious bacterial peritonitis that necessitated catheter removal. Minor complications such as minor bacterial peritonitis, catheter dislodgement, tunnel infection, and catheter blockage occurred in 11 patients (27.5%). The mean duration of survival after catheter placement was 11.8 weeks. All patients expired of their primary malignancies in the follow-up. Radiologically placed tunneled peritoneal catheter is safe and effective in palliation of symptomatic malignant ascites.

  9. Radiologically placed tunneled peritoneal catheter in palliation of malignant ascites

    Energy Technology Data Exchange (ETDEWEB)

    Akinci, Devrim; Erol, Bekir; Ciftci, Tuerkmen T. [Hacettepe University, Faculty of Medicine, Department of Radiology, 06100 Ankara (Turkey); Akhan, Okan, E-mail: akhano@tr.net [Hacettepe University, Faculty of Medicine, Department of Radiology, 06100 Ankara (Turkey)

    2011-11-15

    The purpose of this study was to evaluate retrospectively the safety and effectiveness of radiologically placed tunneled peritoneal catheter in palliation of malignant ascites. Between July 2005 and June 2009, 41 tunneled peritoneal catheters were placed under ultrasonographic and fluoroscopic guidance in 40 patients (mean age, 55 years; 22 women) who had symptomatic malignant ascites. No procedure related mortality was observed. Major complication occurred in one patient (2.5%) in the form of serious bacterial peritonitis that necessitated catheter removal. Minor complications such as minor bacterial peritonitis, catheter dislodgement, tunnel infection, and catheter blockage occurred in 11 patients (27.5%). The mean duration of survival after catheter placement was 11.8 weeks. All patients expired of their primary malignancies in the follow-up. Radiologically placed tunneled peritoneal catheter is safe and effective in palliation of symptomatic malignant ascites.

  10. A randomised controlled trial of Heparin versus EthAnol Lock THerapY for the prevention of Catheter Associated infecTion in Haemodialysis patients – the HEALTHY-CATH trial

    Directory of Open Access Journals (Sweden)

    Broom Jennifer K

    2012-11-01

    Full Text Available Abstract Background Tunnelled central venous dialysis catheter use is significantly limited by the occurrence of catheter-related infections. This randomised controlled trial assessed the efficacy of a 48 hour 70% ethanol lock vs heparin locks in prolonging the time to the first episode of catheter related blood stream infection (CRBSI. Methods Patients undergoing haemodialysis (HD via a tunnelled catheter were randomised 1:1 to once per week ethanol locks (with two heparin locks between other dialysis sessions vs thrice per week heparin locks. Results Observed catheter days in the heparin (n=24 and ethanol (n=25 groups were 1814 and 3614 respectively. CRBSI occurred at a rate of 0.85 vs. 0.28 per 1000 catheter days in the heparin vs ethanol group by intention to treat analysis (incident rate ratio (IRR for ethanol vs. heparin 0.17; 95%CI 0.02-1.63; p=0.12. Flow issues requiring catheter removal occurred at a rate of 1.6 vs 1.4 per 1000 catheter days in the heparin and ethanol groups respectively (IRR 0.85; 95% CI 0.20-3.5 p =0.82 (for ethanol vs heparin. Conclusions Catheter survival and catheter-related blood stream infection were not significantly different but there was a trend towards a reduced rate of infection in the ethanol group. This study establishes proof of concept and will inform an adequately powered multicentre trial to definitively examine the efficacy and safety of ethanol locks as an alternative to current therapies used in the prevention of catheter-associated blood stream infections in patients dialysing with tunnelled catheters. Trial Registration Australian New Zealand Clinical Trials Registry ACTRN12609000493246

  11. Music exposure induced prolongation of cardiac allograft survival and generated regulatory CD4⁺ cells in mice.

    Science.gov (United States)

    Uchiyama, M; Jin, X; Zhang, Q; Amano, A; Watanabe, T; Niimi, M

    2012-05-01

    In clinical practice, music has been used to decrease stress, heart rate, and blood pressure and to provide a distraction from disease symptoms. We investigated sound effects on alloimmune responses in murine heart transplantation. Naïve and eardrum-ruptured CBA/N (CBA, H2(K)) underwent transplantation of a C57BL/6 (B6, H2(b)) heart and were exposed to 1 of 3 types of music-opera (La Traviata), classical (Mozart), and New Age (Enya)-or 1 of 6 different single sound frequencies for 7 days. An adoptive transfer study was performed to determine whether regulatory cells were generated in allograft recipients. Cell-proliferation, cytokine, and flow cytometry assessments were also performed. CBA recipients of a B6 graft exposed to opera and classical music had significantly prolonged allograft survival (median survival times [MSTs], 26.5 and 20 days, respectively), whereas those exposed to 6 single sound frequencies and New Age did not (MSTs, 7, 8, 9, 8, 8, 8, and 11 days, respectively). Untreated and eardrum-ruptured CBA rejected B6 grafts acutely (MSTs, 7 and 8.5 days, respectively). Adoptive transfer of whole splenocytes, CD4(+) cells, and CD4(+)CD25(+) cells from opera-exposed primary recipients resulted in significantly prolonged allograft survival in naive secondary recipients (MSTs, 36, 68, and >50 days, respectively). Cell-proliferation, interleukin (IL)-2 and interferon-γ were suppressed in opera-exposed mice, whereas IL-4 and IL-10 from opera-exposed recipients were up-regulated. Flow cytometry studies showed an increased CD4(+)CD25(+)Foxp3(+) cell population in splenocytes from opera-exposed mice. In conclusion, exposure to some types of music may induce prolonged survival of fully allogeneic cardiac allografts and generate CD4(+)CD25(+)Foxp3(+) regulatory cells. Copyright © 2012 Elsevier Inc. All rights reserved.

  12. Qingyihuaji Formula Inhibits Pancreatic Cancer and Prolongs Survival by Downregulating Hes-1 and Hey-1

    Directory of Open Access Journals (Sweden)

    Yanli Xu

    2015-01-01

    Full Text Available The dire prognosis of pancreatic cancer has not markedly improved during past decades. The present study was carried out to explore the effect of Qingyihuaji formula (QYHJ on inhibiting pancreatic cancer and prolonging survival in related Notch signaling pathway. Proliferation of pancreatic cancer cells (SW1990 and PANC-1 was detected by MTT assay at 24, 48, and 72 h with exposure to various concentrations (0.08–50 mg/mL of QYHJ water extract. Pancreatic tumor models of nude mice were divided into three groups randomly (control, QYHJ, and gemcitabine. mRNA and protein expression of Notch target genes (Hes-1, Hey-1, Hey-2, and Hey-L in dissected tumor tissue were detected. Results showed that proliferation of SW1990 cells and PANC-1 cells was inhibited by QYHJ water extract in a dose-dependent and time-dependent manner. QYHJ effectively inhibited tumor growth and prolonged survival time in nude mice. Expression of both Hes-1 and Hey-1 was decreased significantly in QYHJ group, suggesting that Hes-1 and Hey-1 in Notch signaling pathway might be potential targets for QYHJ treatment. This research could help explain the clinical effectiveness of QYHJ and may provide advanced pancreatic cancer patients with a new therapeutic option.

  13. Prolonging survival of corneal transplantation by selective sphingosine-1-phosphate receptor 1 agonist.

    Directory of Open Access Journals (Sweden)

    Min Gao

    Full Text Available Corneal transplantation is the most used therapy for eye disorders. Although the cornea is somewhat an immune privileged organ, immune rejection is still the major problem that reduces the success rate. Therefore, effective chemical drugs that regulate immunoreactions are needed to improve the outcome of corneal transplantations. Here, a sphingosine-1-phosphate receptor 1 (S1P1 selective agonist was systematically evaluated in mouse allogeneic corneal transplantation and compared with the commonly used immunosuppressive agents. Compared with CsA and the non-selective sphingosine 1-phosphate (S1P receptor agonist FTY720, the S1P1 selective agonist can prolong the survival corneal transplantation for more than 30 days with a low immune response. More importantly, the optimal dose of the S1P1 selective agonist was much less than non-selective S1P receptor agonist FTY720, which would reduce the dose-dependent toxicity in drug application. Then we analyzed the mechanisms of the selected S1P1 selective agonist on the immunosuppression. The results shown that the S1P1 selective agonist could regulate the distribution of the immune cells with less CD4+ T cells and enhanced Treg cells in the allograft, moreover the expression of anti-inflammatory cytokines TGF-β1 and IL-10 unregulated which can reduce the immunoreactions. These findings suggest that S1P1 selective agonist may be a more appropriate immunosuppressive compound to effectively prolong mouse allogeneic corneal grafts survival.

  14. Urethral catheters: can we reduce use?

    Directory of Open Access Journals (Sweden)

    van den Akker-van Marle M Elske

    2011-05-01

    Full Text Available Abstract Background Indwelling urinary catheters are the main cause of healthcare-associated urinary tract infections. It can be expected that reduction of the use of urinary catheters will lead to decreased numbers of urinary tract infection. Methods The efficacy of an intervention programme to improve adherence to recommendations to reduce the use of urethral catheters was studied in a before-after comparison in ten Dutch hospitals. The programme detected barriers and facilitators and each individual facility was supported with developing their own intervention strategy. Outcome was evaluated by the prevalence of catheters, alternatives such as diapers, numbers of urinary tract infections, the percentage of correct indications and the duration of catheterization. The costs of the implementation as well as the catheterization were evaluated. Results Of a population of 16,495 hospitalized patients 3335 patients of whom 2943 were evaluable for the study, had a urethral catheter. The prevalence of urethral catheters decreased insignificantly in neurology (OR 0.93; 95% CI 0.77 - 1.13 and internal medicine wards (OR 0.97; 95% CI 0.83 - 1.13, decreased significantly in surgical wards (OR 0.84; 95% CI 0.75 - 0.96, but increased significantly in intensive care (IC and coronary care (CC units (OR 1.48; 95% CI 1.01 - 2.17. The use of alternatives was limited and remained so after the intervention. Duration of catheterization decreased insignificantly in IC/CC units (ratio after/before 0.95; 95% CI 0.78 - 1.16 and neurology (ratio 0.97; 95% CI 0.80 - 1.18 and significantly in internal medicine (ratio 0.81; 95% CI 0.69 - 0.96 and surgery wards (ratio 0.80; 95% CI 0.71 - 0.90. The percentage of correct indications on the day of inclusion increased from 50 to 67% (p Conclusion Targeted implementation of recommendations from an existing guideline can lead to better adherence and cost savings. Especially, hospitals which use a lot of urethral catheters or

  15. Totally implantable venous catheters for chemotherapy: experience in 500 patients

    Directory of Open Access Journals (Sweden)

    Nelson Wolosker

    Full Text Available CONTEXT: Totally implantable devices are increasingly being utilized for chemotherapy treatment of oncological patients, although few studies have been done in our environment to analyze the results obtained from the implantation and utilization of such catheters. OBJECTIVE: To study the results obtained from the implantation of totally implantable catheters in patients submitted to chemotherapy. TYPE OF STUDY: Prospective. SETTING: Hospital do Câncer A.C. Camargo, São Paulo, Brazil. METHODS: 519 totally implantable catheters were placed in 500 patients submitted to chemotherapy, with preference for the use of the right external jugular vein. Evaluations were made of the early and late-stage complications and patient evolution until removal of the device, death or the end of the treatment. RESULTS: The prospective analysis showed an average duration of 353 days for the catheters. There were 427 (82.2% catheters with no complications. Among the early complications observed, there were 15 pathway hematomas, 8 cases of thrombophlebitis of the distal stump of the external jugular vein and one case of pocket infection. Among the late-stage complications observed, there were 43 infectious complications (0.23/1000 days of catheter use, 11 obstructions (0.06/1000 days of catheter use and 14 cases of deep vein thrombosis (0.07/1000 days of catheter use. Removal of 101 catheters was performed: 35 due to complications and 66 upon terminating the treatment. A total of 240 patients died while the catheter was functioning and 178 patients are still making use of the catheter. CONCLUSION: The low rate of complications obtained in this study confirms the safety and convenience of the use of totally implantable accesses in patients undergoing prolonged chemotherapy regimes.

  16. Use of asymmetric bidirectional catheters with different curvature radius for catheter ablation of cardiac arrhythmias.

    Science.gov (United States)

    Mantziari, Lilian; Suman-Horduna, Irina; Gujic, Marko; Jones, David G; Wong, Tom; Markides, Vias; Foran, John P; Ernst, Sabine

    2013-06-01

    The impact of recently introduced asymmetric bidirectional ablation catheters on procedural parameters and acute success rates of ablation procedures is unknown. We retrospectively analyzed data regarding ablations using a novel bidirectional catheter in a tertiary cardiac center and compared these in 1:5 ratio with a control group of procedures matched for age, gender, operator, and ablation type. A total of 50 cases and 250 controls of median age 60 (50-68) years were studied. Structural heart disease was equally prevalent in both groups (39%) while history of previous ablations was more common in the study arm (54% vs 30%, P = 0.001). Most of the ablation cases were for atrial fibrillation (46%), followed by atrial tachycardia (28%), supraventricular tachycardia (12%), and ventricular tachycardia (14%). Median procedure duration was 128 (52-147) minutes with the bidirectional, versus 143 (105-200) minutes with the conventional catheter (P = 0.232), and median fluoroscopy time was 17 (10-34) minutes versus 23 (12-39) minutes, respectively (P = 0.988). There was a trend toward a lower procedure duration for the atrial tachycardia ablations, 89 (52-147) minutes versus 130 (100-210) minutes, P = 0.064. The procedure was successfully completed in 96% of the bidirectional versus 84% of the control cases (P = 0.151). A negative correlation was observed between the relative fluoroscopy duration and the case number (r = -0.312, P = 0.028), reflecting the learning curve for the bidirectional catheter. The introduction of the bidirectional catheter resulted in no prolongation of procedure parameters and similar success rates, while there was a trend toward a lower procedure duration for atrial tachycardia ablations. ©2013, The Authors. Journal compilation ©2013 Wiley Periodicals, Inc.

  17. Overexpression of thioredoxin in islets transduced by a lentiviral vector prolongs graft survival in autoimmune diabetic NOD mice

    Directory of Open Access Journals (Sweden)

    Sytwu Huey-Kang

    2009-08-01

    Full Text Available Abstract Pancreatic islet transplantation is considered an appropriate treatment to achieve insulin independence in type I diabetic patients. However, islet isolation and transplantation-induced oxidative stress and autoimmune-mediated destruction are still the major obstacles to the long-term survival of graft islets in this potential therapy. To protect islet grafts from inflammatory damage and prolong their survival, we transduced islets with an antioxidative gene thioredoxin (TRX using a lentiviral vector before transplantation. We hypothesized that the overexpression of TRX in islets would prolong islet graft survival when transplanted into diabetic non-obese diabetic (NOD mice. Methods Islets were isolated from NOD mice and transduced with lentivirus carrying TRX (Lt-TRX or enhanced green fluorescence protein (Lt-eGFP, respectively. Transduced islets were transplanted under the left kidney capsule of female diabetic NOD mice, and blood glucose concentration was monitored daily after transplantation. The histology of the islet graft was assessed at the end of the study. The protective effect of TRX on islets was investigated. Results The lentiviral vector effectively transduced islets without altering the glucose-stimulating insulin-secretory function of islets. Overexpression of TRX in islets reduced hydrogen peroxide-induced cytotoxicity in vitro. After transplantation into diabetic NOD mice, euglycemia was maintained for significantly longer in Lt-TRX-transduced islets than in Lt-eGFP-transduced islets; the mean graft survival was 18 vs. 6.5 days (n = 9 and 10, respectively, p Conclusion We successfully transduced the TRX gene into islets and demonstrated that these genetically modified grafts are resistant to inflammatory insult and survived longer in diabetic recipients. Our results further support the concept that the reactive oxygen species (ROS scavenger and antiapoptotic functions of TRX are critical to islet survival after

  18. Bi-layer sandwich film for antibacterial catheters.

    Science.gov (United States)

    Franz, Gerhard; Schamberger, Florian; Zare, Hamideh Heidari; Bröskamp, Sara Felicitas; Jocham, Dieter

    2017-01-01

    Background: Approximately one quarter of all nosocomial infections can be attributed to the urinary tract. The infections are supposed to be mainly caused by implantations of urethral catheters and stents. A new catheter design is introduced with the aim to lower the high number of nosocomial urethral infections. In order to avoid limitations to use, the design is first applied to conventional commercially available balloon catheters. Results: The main feature of the design is a sandwich layer on both sides of the catheter wall, which is composed of a fragmented base layer of silver capped by a thin film of poly( p -xylylene). This top layer is mainly designed to release a controlled amount of Ag + ions, which is bactericidal, but not toxic to humans. Simultaneously, the lifetime is prolonged to at least one year. The base layer is electrolessly deposited applying Tollens' reagens, the cap layer is deposited by using chemical vapor deposition. Conclusion: The three main problems of this process, electroless deposition of a fragmented silver film on the surface of an electrically insulating organic polymer, irreproducible evaporation during heating of the precursor, and exponential decrease of the layer thickness along the capillary, have been solved trough the application of a simple electrochemical reaction and two standard principles of physics: Papin's pot and the principle of Le Chatelier.

  19. Bi-layer sandwich film for antibacterial catheters

    Directory of Open Access Journals (Sweden)

    Gerhard Franz

    2017-09-01

    Full Text Available Background: Approximately one quarter of all nosocomial infections can be attributed to the urinary tract. The infections are supposed to be mainly caused by implantations of urethral catheters and stents. A new catheter design is introduced with the aim to lower the high number of nosocomial urethral infections. In order to avoid limitations to use, the design is first applied to conventional commercially available balloon catheters.Results: The main feature of the design is a sandwich layer on both sides of the catheter wall, which is composed of a fragmented base layer of silver capped by a thin film of poly(p-xylylene. This top layer is mainly designed to release a controlled amount of Ag+ ions, which is bactericidal, but not toxic to humans. Simultaneously, the lifetime is prolonged to at least one year. The base layer is electrolessly deposited applying Tollens’ reagens, the cap layer is deposited by using chemical vapor deposition.Conclusion: The three main problems of this process, electroless deposition of a fragmented silver film on the surface of an electrically insulating organic polymer, irreproducible evaporation during heating of the precursor, and exponential decrease of the layer thickness along the capillary, have been solved trough the application of a simple electrochemical reaction and two standard principles of physics: Papin’s pot and the principle of Le Chatelier.

  20. In vitro chemo-sensitivity assay guided chemotherapy is associated with prolonged overall survival in cancer patients.

    Science.gov (United States)

    Udelnow, Andrej; Schönfęlder, Manfred; Würl, Peter; Halloul, Zuhir; Meyer, Frank; Lippert, Hans; Mroczkowski, Paweł

    2013-06-01

    The overall survival (OS) of patients suffering From various tumour entities was correlated with the results of in vitro-chemosensitivity assay (CSA) of the in vivo applied drugs. Tumour specimen (n=611) were dissected in 514 patients and incubated for primary tumour cell culture. The histocytological regression assay was performed 5 days after adding chemotherapeutic substances to the cell cultures. n=329 patients undergoing chemotherapy were included in the in vitro/in vivo associations. OS was assessed and in vitro response groups compared using survival analysis. Furthermore Cox-regression analysis was performed on OS including CSA, age, TNM classification and treatment course. The growth rate of the primary was 73-96% depending on tumour entity. The in-vitro response rate varied with histology and drugs (e.g. 8-18% for methotrexate and 33-83% for epirubicine). OS was significantly prolonged for patients treated with in vitro effective drugs compared to empiric therapy (log-rank-test, p=0.0435). Cox-regression revealed that application of in vitro effective drugs, residual tumour and postoperative radiotherapy determined the death risk independently. When patients were treated with drugs effective in our CSA, OS was significantly prolonged compared to empiric therapy. CSA guided chemotherapy should be compared to empiric treatment by a prospective randomized trial.

  1. Malfunctioning and infected tunneled infusion catheters: over-the-wire catheter exchange versus catheter removal and replacement.

    Science.gov (United States)

    Guttmann, David M; Trerotola, Scott O; Clark, Timothy W; Dagli, Mandeep; Shlansky-Goldberg, Richard D; Itkin, Maxim; Soulen, Michael C; Mondschein, Jeffrey I; Stavropoulos, S William

    2011-05-01

    To compare the safety and effectiveness of over-the-wire catheter exchange (catheter-exchange) with catheter removal and replacement (removal-replacement) at a new site for infected or malfunctioning tunneled infusion catheters. Using a quality assurance database, 61 patients with tunneled infusion catheters placed during the period July 2001 to June 2009 were included in this study. Patients receiving hemodialysis catheters were excluded. Catheter-exchange was performed in 25 patients, and same-day removal-replacement was performed in 36 patients. Data collected included demographic information, indication for initial catheter placement and replacement, dwell time for the new catheter, and ultimate fate of the new device. Statistical comparisons between the two cohorts were analyzed using the Kaplan-Meier technique and Fisher exact test. Catheters exchanged over the wire remained functional without infection for a median of 102 days (range, 2-570 days), whereas catheters removed and replaced were functional for a median 238 days (range, 1-292 days, P = .12). After catheter replacement, there were 11 instances of subsequent infection in the catheter-exchange group and 7 instances in the removal-replacement cohort, accounting for infection rates of 4.4 and 2.3 per 1,000 catheter days (P = .049). Patients in the catheter-exchange group had 3.2 greater odds of infection compared with patients in the removal-replacement group. Five malfunction events occurred in each group, accounting for 2.0 and 1.7 malfunctions per 1,000 catheter days in the catheter-exchange and removal-replacement groups (P = .73). Catheter-exchange of tunneled infusion catheters results in a higher infection rate compared with removal-replacement at a new site. The rate of catheter malfunction is not significantly different between the two groups. Catheter-exchange is an alternative for patients with tunneled infusion catheters who have limited venous access, but this technique should not be

  2. Atrial fibrillation ablation using a closed irrigation radiofrequency ablation catheter.

    Science.gov (United States)

    Golden, Keith; Mounsey, John Paul; Chung, Eugene; Roomiani, Pahresah; Morse, Michael Andew; Patel, Ankit; Gehi, Anil

    2012-05-01

    Catheter ablation is an effective therapy for symptomatic, medically refractory atrial fibrillation (AF). Open-irrigated radiofrequency (RF) ablation catheters produce transmural lesions at the cost of increased fluid delivery. In vivo models suggest closed-irrigated RF catheters create equivalent lesions, but clinical outcomes are limited. A cohort of 195 sequential patients with symptomatic AF underwent stepwise AF ablation (AFA) using a closed-irrigation ablation catheter. Recurrence of AF was monitored and outcomes were evaluated using Kaplan-Meier survival analysis and Cox proportional hazards models. Mean age was 59.0 years, 74.9% were male, 56.4% of patients were paroxysmal and mean duration of AF was 5.4 years. Patients had multiple comorbidities including hypertension (76.4%), tobacco abuse (42.1%), diabetes (17.4%), and obesity (mean body mass index 30.8). The median follow-up was 55.8 weeks. Overall event-free survival was 73.6% with one ablation and 77.4% after reablation (reablation rate was 8.7%). Median time to recurrence was 26.9 weeks. AF was more likely to recur in patients being treated with antiarrhythmic therapy at the time of last follow-up (recurrence rate 30.3% with antiarrhythmic drugs, 13.2% without antiarrhythmic drugs; hazard ratio [HR] 2.2, 95% confidence interval [CI] 1.1-4.4, P = 0.024) and in those with a history of AF greater than 2 years duration (HR 2.7, 95% CI 1.1-6.9, P = 0.038). Our study represents the largest cohort of patients receiving AFA with closed-irrigation ablation catheters. We demonstrate comparable outcomes to those previously reported in studies of open-irrigation ablation catheters. Given the theoretical benefits of a closed-irrigation system, a large head-to-head comparison using this catheter is warranted. ©2012, The Authors. Journal compilation ©2012 Wiley Periodicals, Inc.

  3. Catheter Angiography

    Medline Plus

    Full Text Available ... News Physician Resources Professions Site Index A-Z Catheter Angiography Catheter angiography uses a catheter, x-ray ... are the limitations of Catheter Angiography? What is Catheter Angiography? Angiography is a minimally invasive medical test ...

  4. Yogurt Feeding Induced the Prolongation of Fully Major Histocompatibility Complex-Mismatched Murine Cardiac Graft Survival by Induction of CD4+Foxp3+ Cells.

    Science.gov (United States)

    Uchiyama, M; Yin, E; Yanagisawa, T; Jin, X; Hara, M; Matsuyama, S; Imazuru, T; Uchida, K; Kawamura, M; Niimi, M

    Yogurt is a nutrient-rich food and the beneficial effects of yogurt on both health and immunomodulatory effects are well documented. In this pilot study, we investigated the effects of commercially produced yogurt R-1 on alloimmune responses in a murine cardiac transplantation model. The R-1 is produced by Meiji Co., Ltd., and contains live and active lactic acid bacteria (lactobacillus bulgaricus OLL1073R-1) mainly. CBA (H2 k ) mice underwent transplantation of a C57BL/6 (H2 b ; B6) heart and received oral administration of 1 mL, 0.1 mL, and 0.01 mL of R-1 from the day of transplantation until 7 days afterward. Additionally, we prepared one group of CBA recipients given 1 mL of R-1 sterilized by microwave for 7 days. Histological and immunohistochemical studies were performed. Naïve CBA mice rejected B6 cardiac graft acutely (median survival time [MST]: 7 days). CBA recipients given of 1 mL of R-1 had significantly prolonged B6 allograft survival (MST, 27 days). However, other doses of 0.1 mL and 0.01 mL of R-1 did not prolonged allograft survival (MSTs, 9 days and 8.5 days, respectively). Also, CBA recipients administered microwaved R-1 had no prolongation of B6 allograft (MST, 9 days). Histological and immunohistochemical studies showed the cardiac allograft from R-1-exposed CBA recipients had preserved graft and vessel structure and the number of infiltrated CD4 + , CD8 + , and Foxp3 + cells in R-1-exposed CBA recipients increased, respectively. In conclusion, our findings imply that yogurt containing active lactic acid bacteria could change alloimmune responses partially and induce the prolongation of cardiac allograft survival via CD4 + Foxp3 + regulatory cells. Copyright © 2017 Elsevier Inc. All rights reserved.

  5. Urinary catheters

    Science.gov (United States)

    Catheter - urine; Foley catheter; Indwelling catheter; Suprapubic catheters ... stones Blood infections ( septicemia ) Blood in the urine (hematuria) Kidney damage (usually only with long-term, indwelling ...

  6. No prolongation of skin allograft survival by immunoproteasome inhibition in mice.

    Science.gov (United States)

    Mundt, Sarah; Basler, Michael; Sawitzki, Birgit; Groettrup, Marcus

    2017-08-01

    The immunoproteasome, a distinct class of proteasomes, which is inducible under inflammatory conditions and constitutively expressed in monocytes and lymphocytes, is known to shape the antigenic repertoire presented on major histocompatibility complex (MHC) class I molecules. Moreover, inhibition of the immunoproteasome subunit LMP7 ameliorates clinical symptoms of autoimmune diseases in vivo and was shown to suppress the development of T helper cell (Th) 1 and Th17 cells and to promote regulatory T-cell (Treg) generation independently of its function in antigen processing. Since Th1 and Th17 cells are detrimental and Treg cells are critical for transplant acceptance, we investigated the influence of the LMP7-selective inhibitor ONX 0914 in a mixed lymphocyte reaction (MLR) in vitro as well as on allograft rejection in a MHC-disparate (C57BL/6 to BALB/c) and a multiple minor histocompatibility antigen (miHA)-disparate (B10.Br to C3H) model of skin transplantation in vivo. Although we observed reduced allo-specific IL-17 production of T cells in vitro, we found that selective inhibition of LMP7 had neither an influence on allograft survival in an MHC-mismatch model nor in a multiple minor mismatch skin transplantation model. We conclude that inhibition of the immunoproteasome is not effective in prolonging skin allograft survival in skin allotransplantation. Copyright © 2017 Elsevier Ltd. All rights reserved.

  7. Infectious Complications of Radiologically Inserted Hickman Catheters in Patients with Hematologic Disorders

    International Nuclear Information System (INIS)

    Bakker, Jeannette; Overhagen, Hans van; Wielenga, Jenne; Marie, Siem de; Nouwen, Jan; Ridder, Marie A.J. de; Lameris, Johan S.

    1998-01-01

    Purpose: To assess the incidence of infections and its influence on the survival of radiologically inserted Hickman catheters (HCs) in patients with hematologic disorders and to determine factors associated with premature HC removal. Methods: Survival and complications of 175 HCs in 115 patients were studied retrospectively. To describe the data the Kaplan-Meier method and the log-rank test were used, using the date of HC removal due to HC-related infection as endpoint. A stratified Cox regression model was used to determine explanatory factors. Results: Seventy (40%) HCs were removed prematurely because of proven or probable HC-related infections. The incidence of infection leading to HC removal was 4.78 per 1000 catheter-days for proven HC infections. Univariate analysis revealed that acute myeloid leukemia, acute lymphocytic leukemia, or treatment for these diseases, gender, each subsequent catheter in the same patient and insertion site increased the risk of premature removal of the catheter due to infection. Conclusion: Infection is a major problem in patients with HCs. Unfortunately, the factors associated with increased infection rates that were found in this study cannot be influenced. Further studies are necessary to determine the role of environmental conditions in a radiology suite in relation to the risk of developing a catheter-related infection

  8. Central line-associated bloodstream infections and catheter dwell-time: A theoretical foundation for a rule of thumb.

    Science.gov (United States)

    Voets, Philip J G M

    2018-05-14

    Many clinicians know from experience and medical epidemiological literature that the risk of central line-associated bloodstream infections (CLABSI) increases rapidly with a prolonged catheter dwell-time, but how this infection risk increases over time remains obscure. In this manuscript, a clinically useful rule of thumb is derived, stating that the risk of CLABSI increases in a quadratic fashion with the increase in catheter dwell-time. The proposed rule of thumb could be considered a quick and effortless clinical tool to rationally predict the pattern of CLABSI risk with an increasing catheter dwell-time. Copyright © 2018. Published by Elsevier Ltd.

  9. Induction of tolerance and prolongation of islet allograft survival by syngeneic hematopoietic stem cell transplantation in mice.

    Science.gov (United States)

    Yang, Shi-feng; Xue, Wu-jun; Lu, Wan-hong; Xie, Li-yi; Yin, Ai-ping; Zheng, Jin; Sun, Ji-ping; Li, Yang

    2015-10-01

    Syngeneic or autologous hematopoietic stem cells transplantation (HSCT) has been proposed to treat autoimmune diseases because of its immunosuppressive and immunomodulatory effects, which can also contribute to posttransplant antirejection therapy. In this study, we explored the tolerogenic effect of syngeneic HSCT on prolonging islet allograft survival. C57BL/6 mice received syngeneic HSCT plus preconditioning with sublethal irradiation. Then islets of BALB/c mice were transplanted into the renal subcapsular of C57BL/6 mice after chemically induced into diabetes. HSCT mice exhibited improved islet allograft survival and increased serum insulin compared to control mice. Islet allografts of HSCT mice displayed lower level lymphocyte infiltration and stronger insulin staining than control mice. T cells of HSCT mice proliferated poorly in response to allogeneic splenocytes compared to control mice. Mice appeared reversed interferon-γ (IFN-γ)/interleukin-4 (IL-4) ratio to a Th2 immune deviation after syngeneic HSCT. The percentage of CD8(+) T cells was lower, while percentage of CD4(+)CD25(+)Foxp3(+) T regulatory cells (Tregs) was higher in HSCT mice than control mice. HSCT mice showed higher percentage of CTLA-4(+) T cells and expression of CTLA-4 mRNA than control mice. Targeting of CTLA-4 by intraperitoneal injection of anti-CTLA-4 mAb abrogated the effect of syngeneic HSCT on prolonging islet allograft survival, inhibiting activity of T cells in response to alloantigen, promoting Th1 to Th2 immune deviation and up regulating CD4(+)CD25(+)Foxp3(+) Tregs. Syngeneic HSCT plus preconditioning of sublethal irradiation induces tolerance and improves islet allograft survival in fully mismatched mice model. Th1 to Th2 immune deviation, increased CD4(+)CD25(+)Foxp3(+) Tregs and up-regulation of CTLA-4 maybe contribute to the tolerogenic effect induced by syngeneic HSCT. Copyright © 2015 Elsevier B.V. All rights reserved.

  10. Transversus Abdominis Plane Catheter Bolus Analgesia after Major Abdominal Surgery

    Directory of Open Access Journals (Sweden)

    Nils Bjerregaard

    2012-01-01

    Full Text Available Purpose. Transversus abdominis plane (TAP blocks have been shown to reduce pain and opioid requirements after abdominal surgery. The aim of the present case series was to demonstrate the use of TAP catheter injections of bupivacaine after major abdominal surgery. Methods. Fifteen patients scheduled for open colonic resection surgery were included. After induction of anesthesia, bilateral TAP catheters were placed, and all patients received a bolus dose of 20 mL bupivacaine 2.5 mg/mL with epinephrine 5 μg/mL through each catheter. Additional bolus doses were injected bilaterally 12, 24, and 36 hrs after the first injections. Supplemental pain treatment consisted of paracetamol, ibuprofen, and gabapentin. Intravenous morphine was used as rescue analgesic. Postoperative pain was rated on a numeric rating scale (NRS, 0–10 at regular predefined intervals after surgery, and consumption of intravenous morphine was recorded. Results. The TAP catheters were placed without any technical difficulties. NRS scores were ≤3 at rest and ≤5 during cough at 4, 8, 12, 18, 24, and 36 hrs after surgery. Cumulative consumption of intravenous morphine was 28 (23–48 mg (median, IQR within the first 48 postoperative hours. Conclusion. TAP catheter bolus injections can be used to prolong analgesia after major abdominal surgery.

  11. Central venous catheters: detection of catheter complications and therapeutical options

    International Nuclear Information System (INIS)

    Gebauer, B.; Beck, A.; Wagner, H.J.; Vivantes-Kliniken, Hellersdorf und Prenzlauer Berg

    2008-01-01

    For modern medicine central venous catheters play an important role for diagnostic and therapeutic options. Catheter implantation, complication detection and therapy of catheter complications are an increasing demand for the radiologist. The review article provides an overview of different catheter types, their indications, advantages and disadvantages. Catheter malpositions are usually detectable in conventional X-ray. Most malpositions are correctable using interventional-radiological techniques. In addition therapeutical options for thrombotic complications (venous thrombosis, catheter occlusion, fibrin sheath) are discussed. In case of an infectious catheter complication, usually a catheter extraction and re-implantation is necessary

  12. Prolonged survival when temozolomide is added to accelerated radiotherapy for glioblastoma multiforme

    Energy Technology Data Exchange (ETDEWEB)

    Guckenberger, Matthias; Mayer, Mario; Sweeney, Reinhart A.; Flentje, Michael [University Hospital Wuerzburg (Germany). Dept. of Radiation Oncology; Buttmann, Mathias [University Hospital Wuerzburg (Germany). Dept. of Neurology; Vince, Giles H. [University Hospital Wuerzburg (Germany). Dept. of Neurosurgery

    2011-09-15

    The goal of this study was to evaluate accelerated radiotherapy with and without temozolomide (TMZ) for glioblastoma multiforme (GBM). This retrospective analysis evaluated 86 patients with histologically proven GBM who were treated with accelerated radiotherapy of 1.8 Gy twice daily to a total dose of 54 Gy within 3 weeks. Median age was 62 years and median Karnofsky index was 90. A total of 41 patients received radiotherapy only from 2002-2005 and 45 patients were treated with TMZ concomitantly and after radiotherapy from 2005-2007. Median overall survival (OS) was 12.5 months and 2-year OS was 15.4%. Patient characteristics were well balanced between the two groups except for better performance status (p = 0.05) and higher frequency of retreatment for the first recurrence (p = 0.02) in the TMZ group. Age at diagnosis (HR 2.83) and treatment with TMZ (HR 0.60) were correlated with OS in the multivariate analysis: treatment with and without TMZ resulted in median OS of 16 months and 11.3 months, respectively. Hematological toxicity grade > II was observed in 2/45 patients and 5/37 patients during simultaneous radiochemotherapy and adjuvant TMZ. TMZ added to accelerated radiotherapy for GBM resulted in prolonged overall survival with low rates of severe hematological toxicity. (orig.)

  13. Prolonged survival when temozolomide is added to accelerated radiotherapy for glioblastoma multiforme

    International Nuclear Information System (INIS)

    Guckenberger, Matthias; Mayer, Mario; Sweeney, Reinhart A.; Flentje, Michael; Buttmann, Mathias; Vince, Giles H.

    2011-01-01

    The goal of this study was to evaluate accelerated radiotherapy with and without temozolomide (TMZ) for glioblastoma multiforme (GBM). This retrospective analysis evaluated 86 patients with histologically proven GBM who were treated with accelerated radiotherapy of 1.8 Gy twice daily to a total dose of 54 Gy within 3 weeks. Median age was 62 years and median Karnofsky index was 90. A total of 41 patients received radiotherapy only from 2002-2005 and 45 patients were treated with TMZ concomitantly and after radiotherapy from 2005-2007. Median overall survival (OS) was 12.5 months and 2-year OS was 15.4%. Patient characteristics were well balanced between the two groups except for better performance status (p = 0.05) and higher frequency of retreatment for the first recurrence (p = 0.02) in the TMZ group. Age at diagnosis (HR 2.83) and treatment with TMZ (HR 0.60) were correlated with OS in the multivariate analysis: treatment with and without TMZ resulted in median OS of 16 months and 11.3 months, respectively. Hematological toxicity grade > II was observed in 2/45 patients and 5/37 patients during simultaneous radiochemotherapy and adjuvant TMZ. TMZ added to accelerated radiotherapy for GBM resulted in prolonged overall survival with low rates of severe hematological toxicity. (orig.)

  14. Catheter Angiography

    Medline Plus

    Full Text Available ... Z Catheter Angiography Catheter angiography uses a catheter, x-ray imaging guidance and an injection of contrast material ... vessels in the body. Angiography is performed using: x-rays with catheters computed tomography (CT) magnetic resonance imaging ( ...

  15. Systemic administration of bevacizumab prolongs survival in an in vivo model of platinum pre-treated ovarian cancer

    Science.gov (United States)

    REIN, DANIEL T.; VOLKMER, ANNE KATHRIN; VOLKMER, JENS; BEYER, INES M.; JANNI, WOLFGANG; FLEISCH, MARKUS C.; WELTER, ANNE KATHRIN; BAUERSCHLAG, DIRK; SCHÖNDORF, THOMAS; BREIDENBACH, MARTINA

    2012-01-01

    Ovarian cancer patients often suffer from malignant ascites and pleural effusion. Apart from worsening the outcome, this condition frequently impairs the quality of life in patients who are already distressed by ovarian cancer. This study investigated whether single intraperitoneal administration of the anti-VEGF antibody bevacizumab is capable of reducing the ascites-related body surface and prolonging survival. The study was performed in an orthotopic murine model of peritoneal disseminated platin-resistant ovarian cancer. Mice were treated with bevacizumab and/or paclitaxel or buffer (control). Reduction of body surface and increased survival rates were assessed as therapeutic success. Survival of mice in all treatment groups was significantly enhanced when compared to the non-treatment control group. The combination of paclitaxel plus bevacizumab significantly improved body surface as well as overall survival in comparison to a treatment with only one of the drugs. Treatment of malignant effusion with a single dose of bevacizumab as an intraperitoneal application, with or without cytostatic co-medication, may be a powerful alternative to systemic treatment. PMID:22740945

  16. Early catheter removal after radical retropubic prostatectomy: long-term followup.

    Science.gov (United States)

    Koch, Michael O; Nayee, Anish H; Sloan, James; Gardner, Thomas; Wahle, Greg R; Bihrle, Richard; Foster, Richard S

    2003-06-01

    We examine the complication and continence rates with early catheter removal (day 3 or 4) after radical retropubic prostatectomy. A total of 365 patients with localized prostate cancer underwent radical retropubic prostatectomy at Indiana University Hospital with planned urethral catheter removal before discharge home. Low pressure cystograms were performed on postoperative day 3 or 4 to determine if catheter removal was possible. A subset of patients were analyzed using a validated prostate cancer specific questionnaire (University of California, Los Angeles Prostate Cancer Symptom Index) to determine quality of life outcomes. The catheter was removed on postoperative day 3 or 4 in 263 patients (72%). The reasons for leaving the catheter indwelling were significant leak on cystogram or excessive suprapubic drainage (21%), extensive bladder neck reconstruction (1%) and prolonged hospitalization because of an ileus or other complicating factor (6%). Thirteen patients (3.6%) were either unable to void after catheter removal or presented with retention (not associated with hematuria or clots) after hospital discharge, requiring reinsertion of the Foley catheter. A total of 41 patients (11%) had either an early or late complication (excluding incontinence). There were 3 complications (0.8%) that were considered major because they were potentially life threatening or required a return to the operating room. A pelvic abscess developed in 2 patients and a lymphocele in 1, which required percutaneous drainage. After at least 6 months (mean 20.9 months) 140 patients (89.2%) and 14 (8.9%) reported excellent and good continence, respectively. The patient questionnaire demonstrated bother scores to be minimal to no bother for 95% to 98% of patients at 6 and 12 months. This study confirms that it is safe to remove catheters in most patients 3 to 4 days after prostatectomy if a cystogram demonstrates no extravasation. Complication rates and continence rates with this approach

  17. Urinary catheter - infants

    Science.gov (United States)

    Bladder catheter - infants; Foley catheter - infants; Urinary catheter - neonatal ... A urinary catheter is a small, soft tube placed in the bladder. This article addresses urinary catheters in babies. WHY IS ...

  18. A tumor-targeting p53 nanodelivery system limits chemoresistance to temozolomide prolonging survival in a mouse model of glioblastoma multiforme.

    Science.gov (United States)

    Kim, Sang-Soo; Rait, Antonina; Kim, Eric; Pirollo, Kathleen F; Chang, Esther H

    2015-02-01

    Development of temozolomide (TMZ) resistance contributes to the poor prognosis for glioblastoma multiforme (GBM) patients. It was previously demonstrated that delivery of exogenous wild-type tumor suppressor gene p53 via a tumor-targeted nanocomplex (SGT-53) which crosses the blood-brain barrier could sensitize highly TMZ-resistant GBM tumors to TMZ. Here we assessed whether SGT-53 could inhibit development of TMZ resistance. SGT-53 significantly chemosensitized TMZ-sensitive human GBM cell lines (U87 and U251), in vitro and in vivo. Furthermore, in an intracranial GBM tumor model, two cycles of concurrent treatment with systemically administered SGT-53 and TMZ inhibited tumor growth, increased apoptosis and most importantly, significantly prolonged median survival. In contrast TMZ alone had no significant effect on median survival compared to a single cycle of TMZ. These results suggest that combining SGT-53 with TMZ appears to limit development of TMZ resistance, prolonging its anti-tumor effect and could be a more effective therapy for GBM. Using human glioblastoma multiforma cell lines, this research team demonstrated that the delivery of exogenous wild-type tumor suppressor gene p53 via a tumor-targeted nanocomplex limited the development of temozolomide resistance and prolonged its anti-tumor effect, which may enable future human application of this or similar techniques. Copyright © 2015 Elsevier Inc. All rights reserved.

  19. Selective histone deacetylase 6 inhibition prolongs survival in a lethal two-hit model.

    Science.gov (United States)

    Cheng, Xin; Liu, Zhengcai; Liu, Baoling; Zhao, Ting; Li, Yongqing; Alam, Hasan B

    2015-07-01

    Hemorrhagic shock (HS) followed by a subsequent insult ("second hit") often initiates an exaggerated systemic inflammatory response and multiple organ failure. We have previously demonstrated that valproic acid, a pan histone deacetylase inhibitor, could improve survival in a rodent "two-hit" model. In the present study, our goal was to determine whether selective inhibition of histone deacetylase 6 with Tubastatin A (Tub-A) could prolong survival in a two-hit model where HS was followed by sepsis from cecal ligation and puncture (CLP). C57Bl/6J mice were subjected to sublethal HS (30% blood loss) and then randomly divided into two groups (n = 13 per group) such as Tub-A group (treatment) and vehicle (VEH) group (control). The Tub-A group was given an intraperitoneal injection of Tub-A (70 mg/kg) dissolved in dimethyl sulfoxide (DMSO). The VEH group was injected with DMSO (1 μl/g body weight). After 24 h, all mice were subjected CLP followed immediately by another dose of Tub-A or DMSO. Survival was monitored for 10 d. In a parallel study, peritoneal irrigation fluid and liver tissue from Tub-A- or DMSO-treated mice were collected 3 h after CLP. Enzyme-linked immunosorbent assay was performed to quantify activity of the myeloperoxidase and concentrations of tumor necrosis factor-alpha (TNF-α) and interleukin 6 (IL-6) in the peritoneal irrigation fluid. RNA was isolated from the liver tissue, and real-time polymerase chain reaction was performed to measure relative messenger RNA levels of TNF-α and IL-6. Treatment with Tub-A significantly improved survival compared with that of the control (69.2% versus 15.4%). In addition, Tub-A significantly suppressed myeloperoxidase activity (169.9 ± 8.4 ng/mL versus 70.4 ± 17.4 ng/mL; P hit model. Copyright © 2015 Elsevier Inc. All rights reserved.

  20. Thioredoxin priming prolongs lung allograft survival by promoting immune tolerance.

    Directory of Open Access Journals (Sweden)

    Hanbo Hu

    Full Text Available Tolerance to allograft antigen is the major challenge and final goal of transplant medicine. Our previous study demonstrated that thioredoxin-1 (Trx priming of donor lung significantly protected allogeneic lung graft. To determine whether Trx priming of donor lung inhibits allograft rejection, extends allograft survival and induces immune tolerance, orthotopic left lung transplantation was performed from Lewis to Sprague-Dawley rats without immunosuppression. Donor lungs were primed with Trx at 4°C for 4 hr prior to transplantation. After up to 37 days post-transplantation, allograft lung morphology, recipient T cell and humoral alloantigen-specific immune responses were examined. We found that Trx-primed lungs exhibited much reduced acute rejection and associated lung injuries resulting in loss of graft functional area at 5-37 days post-transplant in contrast to the control groups. CD4+ T cells from the recipients with Trx-primed grafts responded to the stimulation of dendritic cells (DCs of donor origin, in contrast to DCs from the third party, with significantly reduced proliferation. Consistent with above findings, we observed that CD4+Foxp3+ regulatory T cells in spleen cells from the recipients with Trx-primed grafts were significantly increased compared to controls, and CD4+ T cells from the recipients with Trx-primed grafts produced much higher levels of immunosuppressive cytokine, IL-10 when stimulated with allogeneic donor DCs. In addition, humoral immune tolerance was also induced as there was no significant increase levels of serum antibodies against donor antigens in Trx-lung recipients when re-challenged with allogeneic donor antigens. Our results demonstrate that one-time Trx-priming of donor lung grafts prior to transplantation significantly prolongs the survival of the grafts through inducing or promoting cellular and humoral alloantigen-specific immune tolerance, which might be associated with the induction of

  1. Kinetics of hemopoietic stem cells and survival of mice treated with hydroxyurea and exposed to prolonged γ-radiation

    International Nuclear Information System (INIS)

    Chertkov, K.S.; Rogozkin, V.D.; Dikovenko, E.A.; Mosina, Z.M.

    1979-01-01

    A study was made of radioprotective efficiency of hydroxyurea in relation to mice exposed to prolonged 137 Cs-γ-radiation. It was found that a 30-day survival rate, under optimal conditions of treatment with hydroxyurea, was more than 40 per cent higher than that of the controls. The protective effect of hydroxyurea was manifested at the level of hemopoietic stem cells due to a quicker onset and accelerated rate of the repopulation process

  2. Adoptive infusion of tolerogenic dendritic cells prolongs the survival of pancreatic islet allografts: a systematic review of 13 mouse and rat studies.

    Directory of Open Access Journals (Sweden)

    Guixiang Sun

    Full Text Available OBJECTIVE: The first Phase I study of autologous tolerogenic dendritic cells (Tol-DCs in Type 1 diabetes (T1D patients was recently completed. Pancreatic islet transplantation is an effective therapy for T1D, and infusion of Tol-DCs can control diabetes development while promoting graft survival. In this study, we aim to systematically review islet allograft survival following infusion of Tol-DCs induced by different methods, to better understand the mechanisms that mediate this process. METHODS: We searched PubMed and Embase (from inception to February 29(th, 2012 for relevant publications. Data were extracted and quality was assessed by two independent reviewers. We semiquantitatively analyzed the effects of Tol-DCs on islet allograft survival using mixed leukocyte reaction, Th1/Th2 differentiation, Treg induction, and cytotoxic T lymphocyte activity as mechanisms related-outcomes. We discussed the results with respect to possible mechanisms that promote survival. RESULTS: Thirteen articles were included. The effects of Tol-DCs induced by five methods on allograft survival were different. Survival by each method was prolonged as follows: allopeptide-pulsed Tol-DCs (42.14 ± 44 days, drug intervention (39 days, mesenchymal stem cell induction (23 days, genetic modification (8.99 ± 4.75 days, and other derivation (2.61 ± 6.98 days. The results indicate that Tol-DC dose and injection influenced graft survival. Single-dose injections of 10(4 Tol-DCs were the most effective for allograft survival, and multiple injections were not superior. Tol-DCs were also synergistic with immunosuppressive drugs or costimulation inhibitors. Possible mechanisms include donor specific T cell hyporesponsiveness, Th2 differentiation, Treg induction, cytotoxicity against allograft reduction, and chimerism induction. CONCLUSIONS: Tol-DCs induced by five methods prolong MHC mismatched islet allograft survival to different degrees, but allopeptide-pulsed host DCs

  3. PR Interval Associated Genes, Atrial Remodeling and Rhythm Outcome of Catheter Ablation of Atrial Fibrillation—A Gene-Based Analysis of GWAS Data

    Directory of Open Access Journals (Sweden)

    Daniela Husser

    2017-12-01

    Full Text Available Background: PR interval prolongation has recently been shown to associate with advanced left atrial remodeling and atrial fibrillation (AF recurrence after catheter ablation. While different genome-wide association studies (GWAS have implicated 13 loci to associate with the PR interval as an AF endophenotype their subsequent associations with AF remodeling and response to catheter ablation are unknown. Here, we perform a gene-based analysis of GWAS data to test the hypothesis that PR interval candidate genes also associate with left atrial remodeling and arrhythmia recurrence following AF catheter ablation.Methods and Results: Samples from 660 patients with paroxysmal (n = 370 or persistent AF (n = 290 undergoing AF catheter ablation were genotyped for ~1,000,000 SNPs. Gene-based association was investigated using VEGAS (versatile gene-based association study. Among the 13 candidate genes, SLC8A1, MEIS1, ITGA9, SCN5A, and SOX5 associated with the PR interval. Of those, ITGA9 and SOX5 were significantly associated with left atrial low voltage areas and left atrial diameter and subsequently with AF recurrence after radiofrequency catheter ablation.Conclusion: This study suggests contributions of ITGA9 and SOX5 to AF remodeling expressed as PR interval prolongation, low voltage areas and left atrial dilatation and subsequently to response to catheter ablation. Future and larger studies are necessary to replicate and apply these findings with the aim of designing AF pathophysiology-based multi-locus risk scores.

  4. Catheter Angiography

    Medline Plus

    Full Text Available ... of a catheter makes it possible to combine diagnosis and treatment in a single procedure. Catheter angiography ... of a catheter makes it possible to combine diagnosis and treatment in a single procedure. An example ...

  5. Catheter Angiography

    Medline Plus

    Full Text Available ... few millimeters) in the skin where the catheter can be inserted into an artery. The catheter is ... need for surgery. If surgery remains necessary, it can be performed more accurately. Catheter angiography presents a ...

  6. Catheter Angiography

    Medline Plus

    Full Text Available ... resonance imaging (MRI) In catheter angiography, a thin plastic tube, called a catheter , is inserted into an ... The catheter used in angiography is a long plastic tube about as thick as a strand of ...

  7. Catheter Angiography

    Medline Plus

    Full Text Available ... using: x-rays with catheters computed tomography (CT) magnetic resonance imaging (MRI) In catheter angiography, a thin plastic ... called superselective angiography. Unlike computed tomography (CT) or magnetic resonance (MR) angiography , use of a catheter makes it ...

  8. Catheter indwell time and phlebitis development during peripheral intravenous catheter administration.

    Science.gov (United States)

    Pasalioglu, Kadriye Burcu; Kaya, Hatice

    2014-07-01

    Intravenous catheters have been indispensable tools of modern medicine. Although intravenous applications can be used for a multitude of purposes, these applications may cause complications, some of which have serious effects. Of these complications, the most commonly observed is phlebitis. This study was conducted to determine the effect of catheter indwell time on phlebitis development during peripheral intravenous catheter administration. This study determined the effect of catheter indwell time on phlebitis development during peripheral intravenous catheter administration. The study included a total of 103 individuals who were administered 439 catheters and satisfied the study enrollment criteria at one infectious diseases clinic in Istanbul/Turkey. Data were compiled from Patient Information Forms, Peripheral Intravenous Catheter and Therapy Information Forms, reported grades based on the Visual Infusion Phlebitis Assessment Scale, and Peripheral Intravenous Catheter Nurse Observation Forms. The data were analyzed using SPSS. Results : The mean patient age was 53.75±15.54 (standard deviation) years, and 59.2% of the study participants were men. Phlebitis was detected in 41.2% of peripheral intravenous catheters, and the rate decreased with increased catheter indwell time. Analyses showed that catheter indwell time, antibiotic usage, sex, and catheterization sites were significantly associated with development of phlebitis. The results of this study show that catheters can be used for longer periods of time when administered under optimal conditions and with appropriate surveillance.

  9. Microchromatographic study of hippocampal area CA3 proteins during prolonged post-tetanic potentiation in surviving slices

    International Nuclear Information System (INIS)

    Pankova, T.M.; Mikichur, N.I.; Ratushayak, A.S.; Shtark, M.B.

    1985-01-01

    This paper studies the synthesis of proteins and, in particular, of brain-specific proteins in a homogeneous population of postsynaptic cells during the development of prolonged post-tetanic potentiation (PPTP). By using a system of synaptic connections incorporation of tritium-leucine into water-soluble protein of this zone has been investigated during the development of PPTP (in surviving slices after stimulation of mossy fibers). During statistical analysis of the results mean values of deviation of relative radioactivity compared with the control in each fraction was expressed as a percentage. The results were analyzed by Student's test, at the 95% level of significance

  10. Recipient bone marrow-derived stromal cells prolong graft survival in a rat hind limb allotransplantation model.

    Science.gov (United States)

    Ikeguchi, Ryosuke; Kakinoki, Ryosuke; Ohta, Souichi; Oda, Hiroki; Yurie, Hirofumi; Kaizawa, Yukitoshi; Mitsui, Hiroto; Aoyama, Tomoki; Toguchida, Junya; Matsuda, Shuichi

    2017-09-01

    Recent studies have indicated that bone marrow-derived stromal cells (BMSCs) have immunomodulatory properties that suppress the T cell responses that cause graft rejection. The purpose of this study is to evaluate the effect of recipient BMSCs intravenous infusion for immunomodulation in a rat vascularized composite allotransplantation model. A total of nine Wistar (WIS) rats and thirty Lewis (LEW) rats were used. BMSCs were harvested from three LEW rats. Twenty-four LEW rats were used as recipients and divided randomly into four groups: BMSC group, FK group, UT group, and Iso group. In the BMSC group, orthotopic rat hind limb transplantation was performed between WIS donor and LEW recipient rats. Recipient rats were injected intravenously with 2 × 10 6 recipient BMSCs on day 6, and with 0.2 mg/kg/day tacrolimus administered over 7 days (n = 6). In the FK group, recipient rats were treated with tacrolimus alone (n = 6). Rats in the UT group received no immunosuppressive treatment (n = 6). In the Iso group, transplantation was performed from three LEW donor rats to six LEW recipient rats without any immunosuppressive treatment (n = 6). Graft survival was assessed by daily inspection and histology. The immunological reactions of recipients were also evaluated. The graft survival of recipient rats in the BMSC group (24.5 days) was significantly prolonged in comparison with that of the FK group (18 days) (P Recipient rats in the BMSC group had significantly reduced serum IFN-γ cytokine levels (1.571 ± 0.779 pg/ml) in comparison with that of the FK group (7.059 ± 1.522 pg/ml) (P = .001). In in vitro study, BMSCs induce T cell hyporesponsiveness in a mixed lymphocyte reaction. BMSCs induce T cell hyporesponsiveness and prolong graft survival in the rat vascularized composite allotransplantation model. BMSCs exhibit immunomodulatory properties against acute rejection that can be realized without the need for significant recipient

  11. Infraclavicular versus axillary nerve catheters: A retrospective comparison of early catheter failure rate.

    Science.gov (United States)

    Quast, Michaela B; Sviggum, Hans P; Hanson, Andrew C; Stoike, David E; Martin, David P; Niesen, Adam D

    2018-05-01

    Continuous brachial plexus catheters are often used to decrease pain following elbow surgery. This investigation aimed to assess the rate of early failure of infraclavicular (IC) and axillary (AX) nerve catheters following elbow surgery. Retrospective study. Postoperative recovery unit and inpatient hospital floor. 328 patients who received IC or AX nerve catheters and underwent elbow surgery were identified by retrospective query of our institution's database. Data collected included unplanned catheter dislodgement, catheter replacement rate, postoperative pain scores, and opioid administration on postoperative day 1. Catheter failure was defined as unplanned dislodging within 24 h of placement or requirement for catheter replacement and evaluated using a covariate adjusted model. 119 IC catheters and 209 AX catheters were evaluated. There were 8 (6.7%) failed IC catheters versus 13 (6.2%) failed AX catheters. After adjusting for age, BMI, and gender there was no difference in catheter failure rate between IC and AX nerve catheters (p = 0.449). These results suggest that IC and AX nerve catheters do not differ in the rate of early catheter failure, despite differences in anatomic location and catheter placement techniques. Both techniques provided effective postoperative analgesia with median pain scores < 3/10 for patients following elbow surgery. Reasons other than rate of early catheter failure should dictate which approach is performed. Copyright © 2018. Published by Elsevier Inc.

  12. Catheter Angiography

    Medline Plus

    Full Text Available ... lessen your anxiety during the procedure. The area of the groin or arm where the catheter will be inserted is shaved, ... contrast material is injected through the catheter and reaches the blood vessels being studied, several sets of x-rays are taken. Then the catheter is ...

  13. PROLONGED RADIAL ARTERY SPASM IN THE CATHETERIZATION LABORATORY - RELIEF BY PHARMACOLOGICAL INTERVENTION

    Directory of Open Access Journals (Sweden)

    Krishna Kumar

    2010-11-01

    Full Text Available Radial spasm is often very prolonged and painful to the patient. Here, we describe a novel way to deal with the same. The total spasm lasted over 4 hours. A 3.4 6 JR catheter was introduced via the femoral route and papav arine one ampoule was injected directly into the right subclavian artery. After about 10 min we were able to pull out the radial catheter. Radial angiography is a simple procedure with reportedly less complications 1,2. How ever ,it has one major complication radial spasm. We describe here a patient with radial spasm that persisted for more than 2 hours and how we dealt with it.

  14. Evaluation of percutaneous radiologic placement of peritoneal dialysis catheters: technical aspects, results, and complications

    International Nuclear Information System (INIS)

    Hong, Hyun Pyo; Oh, Joo Hyeong; Yoon, Yub; Lee, Tae Won; Ihm, Chun Gyoo

    2001-01-01

    To evaluate the technical aspects, results and complications of the percutaneous radiologic placement of peritoneal dialysis catheters. Between December 1999 and April 2001, 26 peritoneal dialysis catheters were placed percutaneously in 26 consecutive patients by interventional radiologists. The patient group consisted of 16 men and ten women with a mean age of 55 (range, 30-77) years. The results and complications arising were reviewed, and the expected patency of the catheters was determined by means of Kaplan-Meier survival analysis. The technical success rate for catheter placement was 100% (26/26 patients). Severe local bleeding occurred in one patient due to by inferior epigastric artery puncture, and was treated by compression and electronic cautery. The duration of catheter implantation ranged from 1 to 510 days and the patency rate was 416±45 days. Catheter malfunction occurred in four patients. In two, this was restored by manipulation in the intervention room, and in one, through the use of urokinase. In three patients, peritonitis occurred. Catheters were removed from four patients due to malfunction (n=2), peritonitis (n=1), and death (n=1). Percutaneous radiologic placement of a peritoneal dialysis catheter is a relatively simple procedure that reduces the complication rate and improves catheter patency

  15. Evaluation of percutaneous radiologic placement of peritoneal dialysis catheters: technical aspects, results, and complications

    Energy Technology Data Exchange (ETDEWEB)

    Hong, Hyun Pyo; Oh, Joo Hyeong; Yoon, Yub; Lee, Tae Won; Ihm, Chun Gyoo [Kyunghee University Hospital, seoul (Korea, Republic of)

    2001-01-01

    To evaluate the technical aspects, results and complications of the percutaneous radiologic placement of peritoneal dialysis catheters. Between December 1999 and April 2001, 26 peritoneal dialysis catheters were placed percutaneously in 26 consecutive patients by interventional radiologists. The patient group consisted of 16 men and ten women with a mean age of 55 (range, 30-77) years. The results and complications arising were reviewed, and the expected patency of the catheters was determined by means of Kaplan-Meier survival analysis. The technical success rate for catheter placement was 100% (26/26 patients). Severe local bleeding occurred in one patient due to by inferior epigastric artery puncture, and was treated by compression and electronic cautery. The duration of catheter implantation ranged from 1 to 510 days and the patency rate was 416{+-}45 days. Catheter malfunction occurred in four patients. In two, this was restored by manipulation in the intervention room, and in one, through the use of urokinase. In three patients, peritonitis occurred. Catheters were removed from four patients due to malfunction (n=2), peritonitis (n=1), and death (n=1). Percutaneous radiologic placement of a peritoneal dialysis catheter is a relatively simple procedure that reduces the complication rate and improves catheter patency.

  16. Bryostatin and its synthetic analog, picolog rescue dermal fibroblasts from prolonged stress and contribute to survival and rejuvenation of human skin equivalents.

    Science.gov (United States)

    Khan, Tapan K; Wender, Paul A; Alkon, Daniel L

    2018-02-01

    Skin health is associated with the day-to-day activity of fibroblasts. The primary function of fibroblasts is to synthesize structural proteins, such as collagen, extracellular matrix proteins, and other proteins that support the structural integrity of the skin and are associated with younger, firmer, and more elastic skin that is better able to resist and recover from injury. At sub-nanomolar concentrations (0.03-0.3 nM), bryostatin-1 and its synthetic analog, picolog (0.1-10 nM) sustained the survival and activation of human dermal fibroblasts cultured under the stressful condition of prolonged serum deprivation. Bryostatin-1 treatment stabilized human skin equivalents (HSEs), a bioengineered combination of primary human skin cells (keratinocytes and dermal fibroblasts) on an extracellular matrix composed of mainly collagen. Fibroblasts activated by bryostatin-1 protected the structural integrity of HSEs. Bryostatin-1 and picolog prolonged activation of Erk in fibroblasts to promote cell survival. Chronic stress promotes the progression of apoptosis. Dermal fibroblasts constitutively express all components of Fas associated apoptosis, including caspase-8, an initiator enzyme of apoptosis. Prolong bryostatin-1 treatment reduced apoptosis by decreasing caspase-8 and protected dermal fibroblasts. Our data suggest that bryostatin-1 and picolog could be useful in anti-aging skincare, and could have applications in tissue engineering and regenerative medicine. © 2017 Wiley Periodicals, Inc.

  17. Indwelling catheter care

    Science.gov (United States)

    Foley catheter ... You will need to make sure your indwelling catheter is working properly. You will also need to ... not get an infection or skin irritation. Make catheter and skin care part of your daily routine. ...

  18. Beware: The femoral haemodialysis catheter – a surgeon’s perspective

    Directory of Open Access Journals (Sweden)

    Tinus du Toit

    2017-06-01

    Full Text Available The ability to identify and address factors that threaten the optimal utilisation of donor organs is quintessential in obtaining satisfactory transplant outcomes. We share our concerns regarding the prolonged use of femoral haemodialysis catheters and its potential to jeopardise successful renal transplantation. Despite a paucity of literature on the topic, we review relevant aspects related to this pernicious form of vascular access and clarify its limited role in the modern haemodialysis unit, particularly in patients who are still considered for transplantation.

  19. [Fistulae or catheter for elderly who start hemodialysis without permanent vascular access?].

    Science.gov (United States)

    García Cortés, Ma J; Viedma, G; Sánchez Perales, M C; Borrego, F J; Borrego, J; Pérez del Barrio, P; Gil Cunquero, J M; Liébana, A; Pérez Bañasco, V

    2005-01-01

    Autologous access is the best vascular access for dialysis also in older patients and it should be mature when patient needs hemodialysis. It is not always possible. Surgeon availability and demographic characteristics of patients (age, diabetes, vascular disease...) are factors that determine primary vascular access. To analyse outcome and vascular access complications in elderly who start hemodialysis without vascular access. All patients older than 75 years who initiated hemodialysis without vascular access between January 2000 and June 2002 were included, They were divided en two groups depending on primary vascular access. GI: arterio-venous fistulae. GIIl: Tunnelled cuffed catheter. Epidemiological and analytical data, vascular access complications related, as well as patient and first permanent vascular access survival from their inclusion in dialysis up to December 2002 were analysed and compared in both groups. 32 patients were studied. GI: n = 17 (4 men) and GIIl: n =1 5 (8 men), age: 79.9 +/- 3.8 and 81.7 +/- 4 years respectively (ns). There were no differences in sex and comorbidity (diabetes, ischemic heart disease, peripheral vascular disease and hypertension). It took GI 3 months to get a permanent vascular access suitable for using, while it took GIIl 1.3 months (p catheters was higher in GI (3.35 vs 1.87 p central venous thrombosis happen in GI (I: 25 CVT/100 patients-year) vs 30% in GIIl (I = 14.4/100 patients-year) (ns). No significant differences neither in bleeding (66.7% vs 33.3%) nor ischemia (75% vs 25%) were found. Dialysis dose (Kt/V) as well as anaemia degree were similar in both groups. Permanent vascular access survival after 2 years was 45.8% in GI and 24% in GII (ns). Patient survival was similar in GI and GII (72% vs 51% ns). Elderly who start hemodialysis without vascular access took longer to get a suitable permanent vascular access when arterio-venous fistulae is placed than with a tunnelled cuffed hemodialysis catheter. As a

  20. Cost-effectiveness of indwelling pleural catheter compared with talc in malignant pleural effusion.

    Science.gov (United States)

    Olfert, Jordan A P; Penz, Erika D; Manns, Braden J; Mishra, Eleanor K; Davies, Helen E; Miller, Robert F; Luengo-Fernandez, Ramon; Gao, Song; Rahman, Najib M

    2017-05-01

    Malignant pleural effusion is associated with morbidity and mortality. A randomized controlled trial previously compared clinical outcomes and resource use with indwelling pleural catheter (IPC) and talc pleurodesis in this population. Using unpublished quality of life data, we estimate the cost-effectiveness of IPC compared with talc pleurodesis. Healthcare utilization and costs were captured during the trial. Utility weights produced by the EuroQol Group five-dimensional three-level questionnaire and survival were used to determine quality-adjusted life-years (QALYs) gained. The incremental cost-effectiveness ratio (ICER) was calculated over the 1-year trial period. Sensitivity analysis used patient survival data and modelled additional nursing time required per week for catheter drainage. Utility scores, cost and QALYs gained did not differ significantly between groups. The ICER for IPC compared with talc was favorable at $US10 870 per QALY gained. IPC was less costly with a probability exceeding 95% of being cost-effective when survival was pleural effusion in patients without history of prior pleurodesis, with consideration for patient survival, support and preferences. © 2016 The Authors. Respirology published by John Wiley & Sons Australia, Ltd on behalf of Asian Pacific Society of Respirology.

  1. Catheter Angiography

    Medline Plus

    Full Text Available Toggle navigation Test/Treatment Patient Type Screening/Wellness Disease/Condition Safety En Español More Info Images/Videos About Us News Physician Resources Professions Site Index A-Z Catheter Angiography Catheter angiography ...

  2. High-dose stabilized chlorite matrix WF10 prolongs cardiac xenograft survival in the hamster-to-rat model without inducing ultrastructural or biochemical signs of cardiotoxicity

    DEFF Research Database (Denmark)

    Hansen, A; Kemp, K; Kemp, E

    2001-01-01

    of high dose WF10 as a single drug regimen in the hamster-to-rat xenotransplantation model and searched for possible cardiotoxic side effects. WF10 prolonged cardiac xenograft survival, but did not induce tolerence or inhibit pathological signs of acute rejection. Hamsters from the donor population...

  3. Catheter Angiography

    Medline Plus

    Full Text Available ... imaging (MRI) In catheter angiography, a thin plastic tube, called a catheter , is inserted into an artery ... examined, a contrast material is injected through the tube and images are captured using a small dose ...

  4. Catheter Angiography

    Medline Plus

    Full Text Available ... incision in the skin. Once the catheter is guided to the area being examined, a contrast material ... inserted into an artery. The catheter is then guided through the arteries to the area to be ...

  5. Catheter Angiography

    Medline Plus

    Full Text Available ... catheter , is inserted into an artery through a small incision in the skin. Once the catheter is ... the tube and images are captured using a small dose of ionizing radiation ( x-rays ). top of ...

  6. Catheter Angiography

    Medline Plus

    Full Text Available ... it will make the rest of the procedure pain-free. You will not feel the catheter in ... nurse if you notice any bleeding, swelling or pain at the site where the catheter entered the ...

  7. Catheter Angiography

    Medline Plus

    Full Text Available ... should inform the nurse if you notice any bleeding, swelling or pain at the site where the ... Rarely, the catheter punctures the artery, causing internal bleeding. It also is possible that the catheter tip ...

  8. Catheter Angiography

    Medline Plus

    Full Text Available ... an artery through a small incision in the skin. Once the catheter is guided to the area ... small incision (usually a few millimeters) in the skin where the catheter can be inserted into an ...

  9. Catheter Angiography

    Medline Plus

    Full Text Available ... or other procedures such as chemoembolization or selective internal radiation therapy. identify dissection or splitting in the ... days. Rarely, the catheter punctures the artery, causing internal bleeding. It also is possible that the catheter ...

  10. Catheter Angiography

    Medline Plus

    Full Text Available ... is performed using: x-rays with catheters computed tomography (CT) magnetic resonance imaging (MRI) In catheter angiography, ... tumor; this is called superselective angiography. Unlike computed tomography (CT) or magnetic resonance (MR) angiography , use of ...

  11. Catheter Angiography

    Medline Plus

    Full Text Available ... Catheter angiography uses a catheter, x-ray imaging guidance and an injection of contrast material to examine ... removable dental appliances, eye glasses and any metal objects or clothing that might interfere with the x- ...

  12. Catheter Angiography

    Medline Plus

    Full Text Available ... most cases, the kidneys will regain their normal function within five to seven days. Rarely, the catheter ... limitations of Catheter Angiography? Patients with impaired kidney function, especially those who also have diabetes, are not ...

  13. Catheter-related bloodstream infection.

    Science.gov (United States)

    Goede, Matthew R; Coopersmith, Craig M

    2009-04-01

    Catheter-related bloodstream infections (CR-BSIs) are a common, frequently preventable complication of central venous catheterization. CR-BSIs can be prevented by strict attention to insertion and maintenance of central venous catheters and removing unneeded catheters as soon as possible. Antiseptic- or antibiotic-impregnated catheters are also an effective tool to prevent infections. The diagnosis of CR-BSI is made largely based on culture results. CR-BSIs should always be treated with antibiotics, and except in rare circumstances the infected catheter needs to be removed.

  14. Role of contact force-guided radiofrequency catheter ablation for treatment of atrial fibrillation: A systematic review and meta-analysis.

    Science.gov (United States)

    Lin, Hui; Chen, Yi-He; Hou, Jian-Wen; Lu, Zhao-Yang; Xiang, Yin; Li, Yi-Gang

    2017-09-01

    CF-sensing catheter emerged as a novel ablation technology and was increasingly used in clinical practice. Nonetheless, available evidence of efficacy and safety comparison between CF-guided RF catheter ablation and non-CF-guided ablation for treatment of AF was still lacking. Twenty-two eligible studies were included after systematic review through the MEDLINE, Google Scholar, the Cochrane Library and PubMed databases. AF/atrial tachycardia-free survival was markedly improved in CF-guided catheter ablation compared with non-CF-guided ablation at a median 12-month follow-up (RR: 1.12, 95% CI: 1.06-1.19, P = 0.000, fixed). Notably, CF-guided catheter ablation presented a robust survival benefit for treatment of paroxysmal AF (RR: 1.10, 95% CI: 1.03-1.18, P = 0.005, fixed), but not persistent AF (RR: 1.07, 95% CI: 0.89-1.28, P = 0.466, fixed). Moreover, procedure time (WMD: -23.87, 95% CI: -33.83 to -13.91, P = 0.000, random), fluoroscopy time (WMD: -7.78, 95% CI: -13.93 to -1.63, P = 0.013, random) and RF time (WMD: -3.98, 95% CI: -7.78 to -0.17, P = 0.040, random) were significantly reduced in CF-guided catheter ablation. The incidence of procedure-related complications did not differ between these two technologies (RR: 0.83, 95% CI: 0.59 to 1.16, P = 0.271, fixed). CF-guided RF catheter ablation was associated with a significant AF/atrial tachycardia-free survival benefit compared with non-CF-guided ablation in patients with paroxysmal AF rather than persistent AF. In addition, CF-guided ablation strategy also reduced the procedure time, fluoroscopy time, as well as RF time despite no distinct effect on the alleviation of procedure-related complications. © 2017 Wiley Periodicals, Inc.

  15. Catheter Angiography

    Medline Plus

    Full Text Available ... lies. The catheter used in angiography is a long plastic tube about as thick as a strand of spaghetti. top of page How does the procedure work? Catheter angiography works much the same as a ...

  16. Catheter Angiography

    Medline Plus

    Full Text Available ... is performed using: x-rays with catheters computed tomography (CT) magnetic resonance imaging (MRI) In catheter angiography, a ... tumor; this is called superselective angiography. Unlike computed tomography (CT) or magnetic resonance (MR) angiography , use of a ...

  17. A central venous catheter coated with benzalkonium chloride for the prevention of catheter-related microbial colonization.

    Science.gov (United States)

    Moss, H A; Tebbs, S E; Faroqui, M H; Herbst, T; Isaac, J L; Brown, J; Elliott, T S

    2000-11-01

    In an attempt to overcome infections associated with central venous catheters, a new antiseptic central venous catheter coated with benzalkonium chloride on the internal and external surfaces has been developed and evaluated in a clinical trial. Patients (235) randomly received either a triple-lumen central venous catheter coated with benzalkonium chloride (117) or a polyurethane non-antiseptic catheter (118). The incidence of microbial colonization of both catheters and retained antiseptic activity of the benzalkonium chloride device following removal were determined. The benzalkonium chloride resulted in a significant reduction of the incidence of microbial colonization on both the internal and external catheter surfaces. The reduction in colonization was detected at both the intradermal (21 benzalkonium chloride catheters vs. 38 controls, P = 0.0016) and distal segments of the antiseptic-coated catheters. Following catheter removal retained activity was demonstrated in benzalkonium chloride catheters which had been in place for up to 12 days. No patients developed adverse reactions to the benzalkonium chloride catheters. The findings demonstrate that the benzalkonium chloride catheter significantly reduced the incidence of catheter-associated colonization.

  18. Percutaneous Intraductal Radiofrequency Ablation for Extrahepatic Distal Cholangiocarcinoma: A Method for Prolonging Stent Patency and Achieving Better Functional Status and Quality of Life

    International Nuclear Information System (INIS)

    Wu, Tian-tian; Li, Wei-min; Li, Hu-cheng; Ao, Guo-kun; Zheng, Fang; Lin, Hu

    2017-01-01

    PurposeThe clinical efficacy of intraductal radiofrequency ablation (RFA) with Habib™ EndoHPB catheter, a newly developed intervention for malignant extrahepatic biliary obstruction, remains uncertain. The aim of this study was to investigate the clinical efficacy of intraductal RFA.MethodsData from 71 patients with extrahepatic distal cholangiocarcinoma were retrospectively analyzed. The study patients were divided into RFA and control groups. The RFA group had undergone percutaneous transhepatic intraductal RFA with a Habib™ EndoHPB catheter, followed by placement of covered or uncovered biliary self-expandable metallic stents (SEMs) whereas the control group had undergone percutaneous transhepatic covered or uncovered SEMs placement. Procedure-related complications, stent patency, patient survival, and postoperative serum bilirubin concentrations were compared between the two groups. The Functional Assessment of Cancer Therapy-Hepatobiliary (FACT-Hep) questionnaire was administered to evaluate functional status, improvement in clinical manifestations, and quality of life.ResultsThe RFA group had a longer median stent patency than the control group (p = 0.001 for uncovered SEMs placement). Higher functional well-being, hepatobiliary-specific cancer subscale, Trial Outcome Index, and total FACT-Hep scores were observed during post-procedure follow-up in the RFA group. However, median survival did not differ significantly between the two groups (p > 0.05).ConclusionsProlongation of stent patency and better functional status and quality of life, which are all important clinical endpoints, were observed in patients treated with intraductal RFA. Prospective randomized controlled clinical trials are necessary to further investigate the clinical efficacy and long-term benefits of intraductal RFA.

  19. Percutaneous Intraductal Radiofrequency Ablation for Extrahepatic Distal Cholangiocarcinoma: A Method for Prolonging Stent Patency and Achieving Better Functional Status and Quality of Life

    Energy Technology Data Exchange (ETDEWEB)

    Wu, Tian-tian, E-mail: matthewwu1979@hotmail.com; Li, Wei-min, E-mail: weimin-li-surgery@126.com [The 309th Hospital of PLA, Hepatobiliary Surgery Department (China); Li, Hu-cheng, E-mail: hucheng-li-surgery@126.com [The 307th Hospital of PLA, General Surgery Department (China); Ao, Guo-kun, E-mail: guokun-ao-radiology@126.com [The 309th Hospital of PLA, Radiology Department (China); Zheng, Fang, E-mail: fang-zheng-surgery@126.com [The 309th Hospital of PLA, Hepatobiliary Surgery Department (China); Lin, Hu, E-mail: hu-lin-radiology@126.com [The 309th Hospital of PLA, Radiology Department (China)

    2017-02-15

    PurposeThe clinical efficacy of intraductal radiofrequency ablation (RFA) with Habib™ EndoHPB catheter, a newly developed intervention for malignant extrahepatic biliary obstruction, remains uncertain. The aim of this study was to investigate the clinical efficacy of intraductal RFA.MethodsData from 71 patients with extrahepatic distal cholangiocarcinoma were retrospectively analyzed. The study patients were divided into RFA and control groups. The RFA group had undergone percutaneous transhepatic intraductal RFA with a Habib™ EndoHPB catheter, followed by placement of covered or uncovered biliary self-expandable metallic stents (SEMs) whereas the control group had undergone percutaneous transhepatic covered or uncovered SEMs placement. Procedure-related complications, stent patency, patient survival, and postoperative serum bilirubin concentrations were compared between the two groups. The Functional Assessment of Cancer Therapy-Hepatobiliary (FACT-Hep) questionnaire was administered to evaluate functional status, improvement in clinical manifestations, and quality of life.ResultsThe RFA group had a longer median stent patency than the control group (p = 0.001 for uncovered SEMs placement). Higher functional well-being, hepatobiliary-specific cancer subscale, Trial Outcome Index, and total FACT-Hep scores were observed during post-procedure follow-up in the RFA group. However, median survival did not differ significantly between the two groups (p > 0.05).ConclusionsProlongation of stent patency and better functional status and quality of life, which are all important clinical endpoints, were observed in patients treated with intraductal RFA. Prospective randomized controlled clinical trials are necessary to further investigate the clinical efficacy and long-term benefits of intraductal RFA.

  20. Prolonged Elevated Heart Rate and 90-Day Survival in Acutely Ill Patients: Data From the MIMIC-III Database.

    Science.gov (United States)

    Sandfort, Veit; Johnson, Alistair E W; Kunz, Lauren M; Vargas, Jose D; Rosing, Douglas R

    2018-01-01

    We sought to evaluate the association of prolonged elevated heart rate (peHR) with survival in acutely ill patients. We used a large observational intensive care unit (ICU) database (Multiparameter Intelligent Monitoring in Intensive Care III [MIMIC-III]), where frequent heart rate measurements were available. The peHR was defined as a heart rate >100 beats/min in 11 of 12 consecutive hours. The outcome was survival status at 90 days. We collected heart rates, disease severity (simplified acute physiology scores [SAPS II]), comorbidities (Charlson scores), and International Classification of Diseases (ICD) diagnosis information in 31 513 patients from the MIMIC-III ICU database. Propensity score (PS) methods followed by inverse probability weighting based on the PS was used to balance the 2 groups (the presence/absence of peHR). Multivariable weighted logistic regression was used to assess for association of peHR with the outcome survival at 90 days adjusting for additional covariates. The mean age was 64 years, and the most frequent main disease category was circulatory disease (41%). The mean SAPS II score was 35, and the mean Charlson comorbidity score was 2.3. Overall survival of the cohort at 90 days was 82%. Adjusted logistic regression showed a significantly increased risk of death within 90 days in patients with an episode of peHR ( P < .001; odds ratio for death 1.79; confidence interval, 1.69-1.88). This finding was independent of median heart rate. We found a significant association of peHR with decreased survival in a large and heterogenous cohort of ICU patients.

  1. Factors Promoting Survival After Prolonged Resuscitation Attempts: A Case of Survival With Good Neurological Outcome Following 60 Minutes of Downtime After Out-of-Hospital Cardiac Arrest.

    Science.gov (United States)

    Bell, Douglas; Gluer, Robert; Murdoch, Dale

    2018-03-01

    Sudden cardiac arrest is a significant cause of death affecting approximately 25,000 people in Australia annually. We present an out-of-hospital cardiac arrest (OHCA) with prolonged down time and recurrent ventricular arrhythmias treated with extra-corporeal membrane oxygenation. The patient survived to hospital discharge with good neurological outcome. The patient's excellent outcome was a result of immediate good quality CPR, high level premorbid function, reversible cause of arrest and rapid access to an ECMO centre. Copyright © 2017 Australian and New Zealand Society of Cardiac and Thoracic Surgeons (ANZSCTS) and the Cardiac Society of Australia and New Zealand (CSANZ). Published by Elsevier B.V. All rights reserved.

  2. Clinical usefulness of catheter-drawn blood samples and catheter tip cultures for the diagnosis of catheter-related bloodstream infections in neonatology: A systematic review.

    Science.gov (United States)

    Ferreira, Janita; Camargos, Paulo Augusto Moreira; Clemente, Wanessa Trindade; Romanelli, Roberta Maia de Castro

    2018-01-01

    Neonatal sepsis is the most frequent health care-associated infection in neonatal units. This study aimed to analyze articles on the clinical usefulness of catheter-drawn blood samples and catheter tip cultures for the diagnosis of intravascular catheter-related bloodstream infection (CRBSI) in neonates. A systematic search was performed for studies published from 1987-2017, without language restriction. Observational studies carried out in neonates with CRBSI diagnosed using catheter-drawn blood samples or catheter tip cultures were included. A total of 412 articles were identified in the databases and 10 articles were included. The 7 studies that evaluated central venous catheter tip cultures and cultures of catheter fragments presented sensitivities ranging from 58.5%-100% and specificities ranging from 60%-95.7%. Three studies that evaluated catheter-drawn blood cultures, paired with peripheral blood cultures, reported sensitivity and specificity of 94% and 71% when evaluated for the differential time to positivity. When quantitative evaluation was performed, the sensitivity and specificity were 80% and 99.4%. Most of the studies analyzed cultures from the central venous catheter tip and catheter fragments for the diagnosis of CRBSI in neonatal populations. The results of this review suggest that the analysis of the catheter-drawn blood samples and catheter tip cultures, paired with peripheral blood cultures, are efficient methods for the diagnosis of CRBSI in neonates. Copyright © 2018 Association for Professionals in Infection Control and Epidemiology, Inc. Published by Elsevier Inc. All rights reserved.

  3. Dedicated radial ventriculography pigtail catheter

    Energy Technology Data Exchange (ETDEWEB)

    Vidovich, Mladen I., E-mail: miv@uic.edu

    2013-05-15

    A new dedicated cardiac ventriculography catheter was specifically designed for radial and upper arm arterial access approach. Two catheter configurations have been developed to facilitate retrograde crossing of the aortic valve and to conform to various subclavian, ascending aortic and left ventricular anatomies. The “short” dedicated radial ventriculography catheter is suited for horizontal ascending aortas, obese body habitus, short stature and small ventricular cavities. The “long” dedicated radial ventriculography catheter is suited for vertical ascending aortas, thin body habitus, tall stature and larger ventricular cavities. This new design allows for improved performance, faster and simpler insertion in the left ventricle which can reduce procedure time, radiation exposure and propensity for radial artery spasm due to excessive catheter manipulation. Two different catheter configurations allow for optimal catheter selection in a broad range of patient anatomies. The catheter is exceptionally stable during contrast power injection and provides equivalent cavity opacification to traditional femoral ventriculography catheter designs.

  4. Catheter Angiography

    Medline Plus

    Full Text Available ... is injected through the catheter and reaches the blood vessels being studied, several sets of x-rays are taken. Then the catheter is removed and the incision site is closed by applying pressure on the area for approximately 10 to 20 ...

  5. Auditory stimulation of opera music induced prolongation of murine cardiac allograft survival and maintained generation of regulatory CD4+CD25+ cells

    Directory of Open Access Journals (Sweden)

    Uchiyama Masateru

    2012-03-01

    Full Text Available Abstract Background Interactions between the immune response and brain functions such as olfactory, auditory, and visual sensations are likely. This study investigated the effect of sounds on alloimmune responses in a murine model of cardiac allograft transplantation. Methods Naïve CBA mice (H2k underwent transplantation of a C57BL/6 (B6, H2b heart and were exposed to one of three types of music--opera (La Traviata, classical (Mozart, and New Age (Enya--or one of six different single sound frequencies, for 7 days. Additionally, we prepared two groups of CBA recipients with tympanic membrane perforation exposed to opera for 7 days and CBA recipients exposed to opera for 7 days before transplantation (pre-treatment. An adoptive transfer study was performed to determine whether regulatory cells were generated in allograft recipients. Immunohistochemical, cell-proliferation, cytokine, and flow cytometry assessments were also performed. Results CBA recipients of a B6 cardiac graft that were exposed to opera music and Mozart had significantly prolonged allograft survival (median survival times [MSTs], 26.5 and 20 days, respectively, whereas those exposed to a single sound frequency (100, 500, 1000, 5000, 10,000, or 20,000 Hz or Enya did not (MSTs, 7.5, 8, 9, 8, 7.5, 8.5 and 11 days, respectively. Untreated, CBA mice with tympanic membrane perforations and CBA recipients exposed to opera for 7 days before transplantation (pre-treatment rejected B6 cardiac grafts acutely (MSTs, 7, 8 and 8 days, respectively. Adoptive transfer of whole splenocytes, CD4+ cells, or CD4+CD25+ cells from opera-exposed primary allograft recipients resulted in significantly prolonged allograft survival in naive secondary recipients (MSTs, 36, 68, and > 100 days, respectively. Proliferation of splenocytes, interleukin (IL-2 and interferon (IFN-γ production was suppressed in opera-exposed mice, and production of IL-4 and IL-10 from opera-exposed transplant recipients increased

  6. ADSORPTION OF CIPROFLOXACIN TO URINARY CATHETERS AND EFFECT ON SUBSEQUENT BACTERIAL ADHESION AND SURVIVAL

    NARCIS (Netherlands)

    REID, G; TIESZER, C; FOERCH, R; BUSSCHER, HJ; KHOURY, AE; BRUCE, AW

    1993-01-01

    The preincubation of urinary catheter material with minimum inhibitory and sub-inhibitory concentrations of ciprofloxacin caused a significant reduction in the adhesion of viable uropathogenic Escherichia coli subsequently exposed to the surfaces for periods of 1, 12, 24 and 48 h. In addition, the

  7. [Anatomical and clinical evaluation regarding the removal of the peritoneal dialysis catheter].

    Science.gov (United States)

    Tăranu, T; Covic, A; Târcoveanu, E; Florea, Laura

    2005-01-01

    To describe CAPD technique survival and causes for catheter removal. The study included 320 end stage renal disease (ESRD) patients, initiated on CAPD between 1995-2003. Definitive catheter removal was required in 44 cases (15.1%), 11 of these (3.79%) receiving renal transplant. Causes for catheter removal were: mechanical obstruction by fibrin (8 cases/2.75%), obstruction by tub bower (1 case/0.34%), by omental muff (6 cases/2%); abdominal wall sepsis (30 cases/ 10.3%); non-responsive bacterial peritonitis (13 cases/4.05%), fungal peritonitis (7 cases/ 2.4%), fecal peritonitis (2 cases/0.68%); transfer to hemodialysis program (31 cases/10.6%); renal transplant (11 cases/3.79%); emergency surgical pathology for: necrotic-hemorrhagic pancreatitis (two cases), intestinal occlusions (six cases), locked hernias (three cases) and locked eventrations(three cases), appendicular peritonitis (two cases). Mortality associated with these procedures and underlying pathology was 1.73%.

  8. Catheter versus non-catheter angiography in isolated third nerve palsy

    International Nuclear Information System (INIS)

    Lee, A.G.

    2007-01-01

    To discuss the controversies surrounding the indications for catheter angiography versus non-catheter and less invasive angiography techniques (e.g. magnetic resonance angiography (MRA) and computerized tomography angiography (CTA)) in the evaluation of patients with a third nerve palsy. Clinical opinion-perspective and literature review. The patient with an isolated third nerve palsy might have a vasculopathic (and typically benign, self limited course) etiology or a life threatening intracranial posterior communicating artery aneurysm. Although it is clear that non-isolated third nerve palsies require imaging directed at the topographical localization of the clinical findings, the evaluation of the neurologically isolated third nerve palsy remains controversial. The completeness of the external (i.e. somatic) motor dysfunction and the presence or absence of internal (i.e. pupillary) dysfunction are generally used to guide the choice of initial neuroimaging. Advances in MRA and CTA technology have reduced but not eliminated our dependence upon catheter angiography in this setting. A properly performed and interpreted MRA or CTA probably will be able to detect greater than 95 % of aneurysms producing a third nerve palsy. The issues surrounding the use of catheter angiography in third nerve palsy are reviewed. If the clinician is highly confident in the capability, availability, and reliability of the neuroradiologist and of their institutional experience and quality of less invasive non-catheter MRA and CTA and if the risk of aneurysm is low or if the risk of angiography is high (e.g. elderly, renal failure, iodinated contrast allergy, risk of stroke) then MRI and MRA (or CTA) may be a reasonable alternative to catheter angiography. Patients with a moderate or uncertain risk of aneurysm and a lower risk for catheter angiography or if there is a low confidence in the quality or the interpretation of the institutional MRA (or CTA) may still require catheter

  9. Dual inhibition of Ang-2 and VEGF receptors normalizes tumor vasculature and prolongs survival in glioblastoma by altering macrophages

    Science.gov (United States)

    Peterson, Teresa E.; Kirkpatrick, Nathaniel D.; Huang, Yuhui; Farrar, Christian T.; Marijt, Koen A.; Kloepper, Jonas; Datta, Meenal; Amoozgar, Zohreh; Seano, Giorgio; Jung, Keehoon; Kamoun, Walid S.; Vardam, Trupti; Snuderl, Matija; Goveia, Jermaine; Chatterjee, Sampurna; Batista, Ana; Muzikansky, Alona; Leow, Ching Ching; Xu, Lei; Batchelor, Tracy T.; Duda, Dan G.; Fukumura, Dai; Jain, Rakesh K.

    2016-01-01

    Glioblastomas (GBMs) rapidly become refractory to anti-VEGF therapies. We previously demonstrated that ectopic overexpression of angiopoietin-2 (Ang-2) compromises the benefits of anti-VEGF receptor (VEGFR) treatment in murine GBM models and that circulating Ang-2 levels in GBM patients rebound after an initial decrease following cediranib (a pan-VEGFR tyrosine kinase inhibitor) administration. Here we tested whether dual inhibition of VEGFR/Ang-2 could improve survival in two orthotopic models of GBM, Gl261 and U87. Dual therapy using cediranib and MEDI3617 (an anti–Ang-2–neutralizing antibody) improved survival over each therapy alone by delaying Gl261 growth and increasing U87 necrosis, effectively reducing viable tumor burden. Consistent with their vascular-modulating function, the dual therapies enhanced morphological normalization of vessels. Dual therapy also led to changes in tumor-associated macrophages (TAMs). Inhibition of TAM recruitment using an anti–colony-stimulating factor-1 antibody compromised the survival benefit of dual therapy. Thus, dual inhibition of VEGFR/Ang-2 prolongs survival in preclinical GBM models by reducing tumor burden, improving normalization, and altering TAMs. This approach may represent a potential therapeutic strategy to overcome the limitations of anti-VEGFR monotherapy in GBM patients by integrating the complementary effects of anti-Ang2 treatment on vessels and immune cells. PMID:27044097

  10. Impact of short-term hemodialysis catheters on the central veins: a catheter venographic study

    Energy Technology Data Exchange (ETDEWEB)

    Oguzkurt, Levent E-mail: loguzkurt@yahoo.com; Tercan, Fahri; Torun, Dilek; Yildirim, Tuelin; Zuemruetdal, Ayseguel; Kizilkilic, Osman

    2004-12-01

    Objective: To determine the incidence of pericatheter sleeve formation, thrombus formation, and stenosis of the central veins in hemodialysis patients with temporary catheters. Methods and material: In this prospective study, 57 patients (40 males, 17 females) with temporary dialysis catheters had catheter venography by pulling back the catheter just before removal. Patient's age range was 25-87 years (mean age, 51 years). The venographic studies were evaluated for pericatheter sleeve formation, thrombus formation, and stenosis of the brachiocephalic vein (BCV) and the superior vena cava (SVC). The IJV could only be evaluated if there was adequate filling during contrast administration. In a subgroup of patients who had had only right IJV or only right SCV catheters, impact of these catheters on the central veins was compared. Results: The catheter location was right internal jugular vein (IJV) in 26 cases, right subclavian vein (SCV) in 27 cases, left IJV in 1 case, and left SCV in 3 cases. Thirty-two patients (56%) had had only one temporary catheter and the rest had had more than one inserted. The mean dwell time for the catheters was 21 days (range 7-59 days). A pericatheter sleeve was detected on venography in 32 (56%) patients and thrombus formation was noted in 16 patients (28%). A total of 41 patients (72%) exhibited pericatheter sleeve and/or thrombus formation. While 19 of the 32 patients (59%) without previous catheterization had a sleeve around the catheter, only 13 (52%) of 25 patients who had had multiple catheters inserted had a sleeve (P>0.05). Of the eight patients (14%) with BCV stenosis, two had >50% stenosis. Only one patient (2%) had mild stenosis of the SVC. Three patients out of 15 (20%) who had diagnostic venography for the IJV had severe stenosis of the vein. Pericatheter sleeve formation was more frequent in women (P<0.05). However, there were no statistical differences with respect to pericatheter sleeve formation, luminal filling

  11. Concurrent use of pigtail and loop snare catheters for percutaneous retrieval of dislodged central venous port catheter

    Directory of Open Access Journals (Sweden)

    Ming-Tsung Chuang

    2011-11-01

    Full Text Available The purpose of this study was to report our experience of percutaneous retrieval of dislodged port catheters with concurrent use of pigtail and loop snare catheters. During a 5-year period at our institute (June 2005 to July 2010, a total of 23 dislodged port catheters were retrieved. The interval between port catheter implantation and dislodged catheter retrieval ranged from 43 days to 1,414 days (mean 586.7 days. The time of delayed retrieval ranged from 1 day to 45 days (mean 4.6 days. All dislodged catheters were retrieved with the concurrent use of pigtail and loop snare catheters via femoral venous route. The prevalence of port catheter dislodgement at our institute was 3.4%. All dislodged port catheters were removed successfully with pigtail and loop snare catheters together. No procedure-related complications were encountered, except for transient arrhythmia in two patients, which required no medication. In conclusion, the concurrent use of pigtail and loop snare catheters is a feasible and easy way for percutaneous retrieval of a dislodged central venous port catheter.

  12. Presymptomatic Treatment with Acetylcholinesterase Antisense Oligonucleotides Prolongs Survival in ALS (G93A-SOD1 Mice

    Directory of Open Access Journals (Sweden)

    Gotkine Marc

    2013-01-01

    Full Text Available Objective. Previous research suggests that acetylcholinesterase (AChE may be involved in ALS pathogenesis. AChE enzyme inhibitors can upregulate AChE transcription which in certain contexts can have deleterious (noncatalytic effects, making them theoretically harmful in ALS, whilst AChE antisense-oligonucleotides (mEN101, which downregulate AChE may be beneficial. Our aim was to investigate whether downregulation of AChE using mEN101 is beneficial in an ALS mouse model. Methods. ALS (G93A-SOD1 mice received saline, mEN101, inverse-EN101, or neostigmine. Treatments were administered from 5 weeks. Disease-onset and survival were recorded. Additional mice were sacrificed for pathological analysis at 15 weeks of age. In a follow-up experiment treatment was started at the symptomatic stage at a higher dose. Results. mEN101 given at the presymptomatic (but not symptomatic stage prolonged survival and attenuated motor-neuron loss in ALS mice. In contrast, neostigmine exacerbated the clinical parameters. Conclusions. These results suggest that AChE may be involved in ALS pathogenesis. The accelerated disease course with neostigmine suggests that any beneficial effects of mEN101 occur through a non-catalytic rather than cholinergic mechanism.

  13. The efficacy of noble metal alloy urinary catheters in reducing catheter-associated urinary tract infection

    Directory of Open Access Journals (Sweden)

    Alanood Ahmed Aljohi

    2016-01-01

    Results: A 90% relative risk reduction in the rate of CAUTI was observed with the noble metal alloy catheter compared to the standard catheter (10 vs. 1 cases, P = 0.006. When considering both catheter-associated asymptomatic bacteriuria and CAUTI, the relative risk reduction was 83% (12 vs. 2 cases, P = 0.005. In addition to CAUTI, the risk of acquiring secondary bacteremia was lower (100% for the patients using noble metal alloy catheters (3 cases in the standard group vs. 0 case in the noble metal alloy catheter group, P = 0.24. No adverse events related to any of the used catheters were recorded. Conclusion: Results from this study revealed that noble metal alloy catheters are safe to use and significantly reduce CAUTI rate in ICU patients after 3 days of use.

  14. Button self-retaining drainage catheter

    International Nuclear Information System (INIS)

    Caridi, James G.; Hawkins, Irvin F.; Akins, E. William; Young, Ronald S.

    1997-01-01

    To help improve patient acceptance of long-term internal/external catheter access to the biliary tract in those with benign biliary obstruction, a simple design allows the catheter end to remain flush with the skin. It consists of a clothes button affixed to the drainage catheter with a wood screw after the catheter has been cut off at the skin exit. This button/screw device has been used successfully in 22 patients over the last 10 years; catheter exchanges were easily accomplished

  15. Intermedin A, a New Labdane Diterpene Isolated from Alpinia intermedia, Prolonged the Survival Time of P-388D1 Tumor-Bearing CDF1 Mice.

    Science.gov (United States)

    Chen, Lih-Geeng; Su, Pei-Jung; Tsai, Po-Wei; Yang, Ling-Ling; Wang, Ching-Chiung

    2017-01-01

    Eight ethanolic extracts of indigenous Taiwanese plants of the genus Alpinia were tested for tumor cytotoxicity against AGS, Hep G2, HeLa, KB, and HL-60 cells. Among the 50 % and 95 % EtOH extracts of eight Alpinia species, the cytotoxic effects of Alpinia intermedia leaves were the strongest. When the leaf extract of A. intermedia was partitioned using n -hexane and aqueous solvents, the n -hexane layer showed a greater cytotoxic effect and could prolong the survival time of P-388D 1 tumor-bearing CDF1 mice. Two new labdane diterpene derivatives, intermedin A ( 1 ) and intermedin B ( 2 ), and coronarin E ( 3 ) were isolated from the n -hexane layer of A. intermedia . Intermedin A induced apoptosis in HL-60 cells at 30 µg/mL and significantly prolonged the survival time of P-388D 1 tumor-bearing CDF 1 mice by 48.7 % at 20 mg/kg of body weight. We suggest that intermedin A is a major compound of A. intermedia and has a cytotoxic effect on HL-60 and P-388D 1 cells. Georg Thieme Verlag KG Stuttgart · New York.

  16. Administration of polysaccharide from Panax notoginseng prolonged the survival of H22 tumor-bearing mice

    Directory of Open Access Journals (Sweden)

    Li HY

    2016-06-01

    Full Text Available Huaiyu Li,1,* Longlong Gu,1,2,* Yuanyuan Zhong,1 Yajuan Chen,1 Lei Zhang,1 Annie R Zhang,3 Robert W Sobol,4,5 Tong Chen,1,6 Jianfeng Li4,5 1Yunnan Key Laboratory of Pharmacology for Natural Products, School of Pharmaceutical Sciences, 2Haiyuan College, Kunming Medical University, Kunming, Yunnan, People’s Republic of China; 3Graduate School of Applied and Professional Psychology, Rutgers, The State University of New Jersey, Piscataway, NJ, 4Department of Oncologic Sciences, 5Mitchell Cancer Institute, University of South Alabama, Mobile, AL, USA; 6Yunnan Panax notoginseng (Burk F.H. Chen Biotechnology and Pharmaceutical Engineering Research Center, Kunming, Yunnan, People’s Republic of China *These authors contributed equally to this work Background: Polysaccharides from various sources are being considered potential sources for the treatment of liver cancer. The aim of this study was to investigate the impact of polysaccharide isolated from Panax notoginseng (PPN on the proliferation of H22 liver cancer cells and the survival of the tumor-bearing mice transplanted with H22 cells.Materials and methods: Polysaccharide from PPN was added to the culture medium of mouse hepatoma H22 cells at different doses. Cell proliferation was assayed with a standard MTT assay. Survival rates of tumor-bearing mice were recorded. Peripheral blood lymphocytes were assayed by flow cytometry. Serum interleukin-2 levels in peripheral blood were measured by enzyme-linked immunosorbent assay.Results: Polysaccharide from PPN inhibited the growth of H22 cells and significantly prolonged the survival of tumor-bearing mice. The increase in activated CD4+ T-cells and the elevation of serum interleukin-2 may contribute to the antitumor activity of PPN.Conclusion: PPN has potential antitumor activity for the treatment of liver cancer. Keywords: polysaccharide, Panax notoginseng, liver cancer, immunotherapy, IL-2

  17. Radioprotective effects of miso (fermented soy bean paste) against radiation in B6C3F1 mice. Increased small intestinal crypt survival, crypt lengths and prolongation of average time to death

    International Nuclear Information System (INIS)

    Ohara, Masayuki; Lu, Huimei; Shiraki, Katsutomo; Ishimura, Yoshimasa; Uesaka, Toshihiro; Katoh, Osamu; Watanabe, Hiromitsu

    2001-01-01

    The radioprotective effect of miso, a fermentation product from soy bean, was investigated with reference to the survival time, crypt survival and jejunum crypt length in male B6C3F1 mice. Miso at three different fermentation stages (early-, medium- and long-term fermented miso) was mixed in MF diet into biscuits at 10% and was administered from 1 week before irradiation. Animal survival in the long-term fermented miso group was significantly prolonged as compared with the short-term fermented miso and MF cases after 8 Gy of 60 Co-γ-ray irradiation at a dose rate of 2 Gy min -1 . Delay in mortality was evident in all three miso groups, with significantly increased survival. At doses of 10 and 12 Gy X-irradiation at a dose rate of 4 Gy min -1 , the treatment with long-term fermented miso significantly increased crypt survival. Also the protective influence against irradiation in terms of crypt lengths in the long-term fermented miso group was significantly greater than in the short-term or medium-term fermented miso and MF diet groups. Thus, prolonged fermentation appears to be very important for protection against radiation effects. (author)

  18. Radioprotective effects of miso (fermented soy bean paste) against radiation in B6C3F1 mice: increased small intestinal crypt survival, crypt lengths and prolongation of average time to death.

    Science.gov (United States)

    Ohara, M; Lu, H; Shiraki, K; Ishimura, Y; Uesaka, T; Katoh, O; Watanabe, H

    2001-12-01

    The radioprotective effect of miso, a fermentation product from soy bean, was investigated with reference to the survival time, crypt survival and jejunum crypt length in male B6C3F1 mice. Miso at three different fermentation stages (early-, medium- and long-term fermented miso) was mixed in MF diet into biscuits at 10% and was administered from 1 week before irradiation. Animal survival in the long-term fermented miso group was significantly prolonged as compared with the short-term fermented miso and MF cases after 8 Gy of 60Co-gamma-ray irradiation at a dose rate of 2Gy min(-1). Delay in mortality was evident in all three miso groups, with significantly increased survival. At doses of 10 and 12 Gy X-irradiation at a dose rate of 4 Gy min(-1), the treatment with long-term fermented miso significantly increased crypt survival. Also the protective influence against irradiation in terms of crypt lengths in the long-term fermented miso group was significantly greater than in the short-term or medium-term fermented miso and MF diet groups. Thus, prolonged fermentation appears to be very important for protection against radiation effects.

  19. Donor Diabetes and Prolonged Cold Ischemia Time Synergistically Increase the Risk of Graft Failure After Liver Transplantation

    NARCIS (Netherlands)

    Brüggenwirth, Isabel M A; Dolgin, Natasha H; Porte, Robert J; Bozorgzadeh, Adel; Martins, Paulo N A

    BACKGROUND: Both prolonged cold ischemia time (CIT) and donor history of diabetes mellitus (DM) are associated with reduced graft survival after liver transplantation. However, it is unknown whether the adverse effect of prolonged CIT on posttransplant graft survival is more pronounced after

  20. Nanoparticle tumor localization, disruption of autophagosomal trafficking, and prolonged drug delivery improve survival in peritoneal mesothelioma.

    Science.gov (United States)

    Liu, Rong; Colby, Aaron H; Gilmore, Denis; Schulz, Morgan; Zeng, Jialiu; Padera, Robert F; Shirihai, Orian; Grinstaff, Mark W; Colson, Yolonda L

    2016-09-01

    The treatment outcomes for malignant peritoneal mesothelioma are poor and associated with high co-morbidities due to suboptimal drug delivery. Thus, there is an unmet need for new approaches that concentrate drug at the tumor for a prolonged period of time yielding enhanced antitumor efficacy and improved metrics of treatment success. A paclitaxel-loaded pH-responsive expansile nanoparticle (PTX-eNP) system is described that addresses two unique challenges to improve the outcomes for peritoneal mesothelioma. First, following intraperitoneal administration, eNPs rapidly and specifically localize to tumors. The rate of eNP uptake by tumors is an order of magnitude faster than the rate of uptake in non-malignant cells; and, subsequent accumulation in autophagosomes and disruption of autophagosomal trafficking leads to prolonged intracellular retention of eNPs. The net effect of these combined mechanisms manifests as rapid localization to intraperitoneal tumors within 4 h of injection and persistent intratumoral retention for >14 days. Second, the high tumor-specificity of PTX-eNPs leads to delivery of greater than 100 times higher concentrations of drug in tumors compared to PTX alone and this is maintained for at least seven days following administration. As a result, overall survival of animals with established mesothelioma more than doubled when animals were treated with multiple doses of PTX-eNPs compared to equivalent dosing with PTX or non-responsive PTX-loaded nanoparticles. Copyright © 2016 Elsevier Ltd. All rights reserved.

  1. Cerebrospinal Fluid Leak at Percutaneous Exit of Ventricular Catheter as a Crucial Risk Factor for External Ventricular Drainage-Related Infection in Adult Neurosurgical Patients.

    Science.gov (United States)

    Park, Jaechan; Choi, Yeon-Ju; Ohk, Boram; Chang, Hyun-Ha

    2018-01-01

    The placement of a ventricular catheter for temporary cerebrospinal fluid (CSF) diversion is associated with a considerable risk of CSF infection. The authors investigated the effect of a CSF leak on CSF-related infection and the predisposing factors for a CSF leak. Fifty-two patients who underwent external ventricular drainage (EVD) for acute hydrocephalus associated with a subarachnoid hemorrhage or intraventricular hemorrhage (IVH) were enrolled in this prospective study. A CSF leak-detection paper (small sterilized filter paper) was applied at the percutaneous catheter exit site to check for any bloody CSF leak. In addition, radiologic and clinical data were collected. Four of the 52 patients (7.7%) developed an EVD-related CSF infection from organisms including Staphylococcus epidermidis (n = 3) and Staphylococcus hominis (n = 1). A prolonged CSF leak >1 day was detected in 9 patients (17.3%) and revealed as a significant risk factor for CSF infection with a 44.4% positive predictive value. Moreover, an IVH >10 mL was found in 11 patients (21.2%) and revealed as a significant predisposing factor for a CSF leak at the percutaneous catheter exit. A prolonged CSF leak for >1 day at the percutaneous catheter exit site is a crucial risk factor for EVD-related CSF infection and an IVH >10 mL is a predisposing factor for a CSF leak. Copyright © 2017 Elsevier Inc. All rights reserved.

  2. Exploring relationships of catheter-associated urinary tract infection and blockage in people with long-term indwelling urinary catheters.

    Science.gov (United States)

    Wilde, Mary H; McMahon, James M; Crean, Hugh F; Brasch, Judith

    2017-09-01

    To describe and explore relationships among catheter problems in long-term indwelling urinary catheter users, including excess healthcare use for treating catheter problems. Long-term urinary catheter users experience repeated problems with catheter-related urinary tract infection and blockage of the device, yet little has been reported of the patterns and relationships among relevant catheter variables. Secondary data analysis was conducted from a sample in a randomised clinical trial, using data from the entire sample of 202 persons over 12 months' participation. Descriptive statistics were used to characterise the sample over time. Zero-inflated negative binomial models were employed for logistic regressions to evaluate predictor variables of the presence/absence and frequencies of catheter-related urinary tract infection and blockage. Catheter-related urinary tract infection was marginally associated with catheter blockage. Problems reported at least once per person in the 12 months were as follows: catheter-related urinary tract infection 57%, blockage 34%, accidental dislodgment 28%, sediment 87%, leakage (bypassing) 67%, bladder spasms 59%, kinks/twists 42% and catheter pain 49%. Regression analysis demonstrated that bladder spasms were significantly related to catheter-related urinary tract infection and sediment amount, and catheter leakages were marginally significantly and positively related to catheter-related urinary tract infection. Frequencies of higher levels of sediment and catheter leakage were significantly associated with higher levels of blockage, and being female was associated with fewer blockages. Persons who need help with eating (more disabled) were also more likely to have blockages. Catheter-related urinary tract infection and blockage appear to be related and both are associated with additional healthcare expenditures. More research is needed to better understand how to prevent adverse catheter outcomes and patterns of problems in

  3. Epidemiology of peritonitis following maintenance peritoneal dialysis catheter placement during infancy: a report of the SCOPE collaborative.

    Science.gov (United States)

    Zaritsky, Joshua Jacob; Hanevold, Coral; Quigley, Raymond; Richardson, Troy; Wong, Cynthia; Ehrlich, Jennifer; Lawlor, John; Rodean, Jonathan; Neu, Alicia; Warady, Bradley A

    2018-04-01

    Maintenance peritoneal dialysis (PD) is the dialysis modality of choice for infants and young children. However, there are limited outcome data for those who undergo PD catheter insertion and initiate maintenance PD within the first year of life. Using data from the Children's Hospital Association's Standardizing Care to Improve Outcomes in Pediatric End Stage Renal Disease (ESRD) Collaborative (SCOPE), we examined peritonitis rates and patient survival in 156 infants from 29 North American pediatric dialysis centers who had a chronic PD catheter placed prior to their first birthday. In-hospital and overall annualized rates of peritonitis were 1.73 and 0.76 episodes per patient-year, respectively. Polycystic kidney disease was the most frequent renal diagnosis and pulmonary hypoplasia the most common co-morbidity in infants with peritonitis. Multivariable regression models demonstrated that nephrectomy at or prior to PD catheter placement and G-tube insertion after catheter placement were associated with a nearly sixfold and nearly threefold increased risk of peritonitis, respectively. Infants with peritonitis had longer initial hospital stays and lower overall survival (86.3 vs. 95.6%, respectively; P high and several risk factors associated with the development of peritonitis were identified. Given that peritonitis was associated with a longer duration of initial hospitalization and increased mortality, increased attention to the potentially modifiable risk factors for infection is needed.

  4. Prolonged Minocycline Treatment Impairs Motor Neuronal Survival and Glial Function in Organotypic Rat Spinal Cord Cultures

    Science.gov (United States)

    Pinkernelle, Josephine; Fansa, Hisham; Ebmeyer, Uwe; Keilhoff, Gerburg

    2013-01-01

    Background Minocycline, a second-generation tetracycline antibiotic, exhibits anti-inflammatory and neuroprotective effects in various experimental models of neurological diseases, such as stroke, Alzheimer’s disease, amyotrophic lateral sclerosis and spinal cord injury. However, conflicting results have prompted a debate regarding the beneficial effects of minocycline. Methods In this study, we analyzed minocycline treatment in organotypic spinal cord cultures of neonatal rats as a model of motor neuron survival and regeneration after injury. Minocycline was administered in 2 different concentrations (10 and 100 µM) at various time points in culture and fixed after 1 week. Results Prolonged minocycline administration decreased the survival of motor neurons in the organotypic cultures. This effect was strongly enhanced with higher concentrations of minocycline. High concentrations of minocycline reduced the number of DAPI-positive cell nuclei in organotypic cultures and simultaneously inhibited microglial activation. Astrocytes, which covered the surface of the control organotypic cultures, revealed a peripheral distribution after early minocycline treatment. Thus, we further analyzed the effects of 100 µM minocycline on the viability and migration ability of dispersed primary glial cell cultures. We found that minocycline reduced cell viability, delayed wound closure in a scratch migration assay and increased connexin 43 protein levels in these cultures. Conclusions The administration of high doses of minocycline was deleterious for motor neuron survival. In addition, it inhibited microglial activation and impaired glial viability and migration. These data suggest that especially high doses of minocycline might have undesired affects in treatment of spinal cord injury. Further experiments are required to determine the conditions for the safe clinical administration of minocycline in spinal cord injured patients. PMID:23967343

  5. Peritoneal catheter fixation combined with straight upward tunnel and low implant position to prevent catheter malfunction.

    Science.gov (United States)

    Zhang, Qingyan; Jiang, Chunming; Zhu, Wei; Sun, Cheng; Xia, Yangyang; Tang, Tianfeng; Wan, Cheng; Shao, Qiuyuan; Liu, Jing; Jin, Bo; Zhang, Miao

    2018-03-01

    Catheter malfunction is the main reason for early peritoneal dialysis (PD) technique failure. This study aimed to evaluate the effect of a new surgery technique with catheter fixation to the lower abdominal wall combined with straight upward tunnel and low implant position in reducing catheter malfunction. Patients with end stage renal disease who received PD in our centre from January 2013 to December 2015 were involved in this study. They were randomly divided into three groups according to surgical technique: traditional open surgery group, modified open surgery group and modified open surgery with catheter fixation group. All patients were followed up for six months after surgery. Catheter- related complications were analyzed. A total of 152 patients were involved. Among them, 49 received traditional open surgery (TOS group), 49 received modified open surgery (MOS group), and 54 received modified open surgery with catheter fixation (MOS-F group). During follow-up, no patients (0%) in MOS-F group developed catheter malfunction which was significantly lower than that of the TOS group (0 vs 16.33%, P = 0.002). Although not statistically significant, the incidence of catheter malfunction was lower in MOS-F group than that in MOS group (0 vs 4.08%, P = 0.134). No significant difference was observed in the episodes of infection, bleeding, leakage, inflow or outflow pain, hernia and delayed wound healing among the three groups (all P > 0.05). Catheter fixation combined with straight upward tunnel and low implant position can effectively prevent catheter malfunction in PD catheter placement. © 2016 Asian Pacific Society of Nephrology.

  6. [The role of the uretral catheter in the development of catheter- related urinary tract infection].

    Science.gov (United States)

    Vasilyev, A O; Govorov, A V; Shiryaev, A A; Pushkar, D Yu

    2017-12-01

    The most common source of nosocomial infection is the urinary tract, especially if they it is drained with a urethral catheter. Catheter-associated urinary tract infections account for at least 80% of all complicated urinary tract infections and are the most common type of hospital-acquired infection. Intestinal microflora plays the leading role in the pathogenesis of catheter-associated urinary tract infections, whereas the most important risk factor for their development is the long duration of urinary catheter drainage. In the case of short-term and intermittent catheterization, routine antibiotic prophylaxis is not required, but if a patient develops clinically significant infection, antibiotic therapy is required followed by definitive therapy based on culture. Urethral catheters coated with antimicrobial substances and anti-inflammatory agents can significantly reduce the adhesion and migration of bacteria, thereby reducing the incidence of urinary tract infections. Despite this, the incidence of catheter-associated infection remains high. We have reviewed recent literature related to catheter-associated urinary tract infections and the best means of preventing this condition.

  7. Epidural Catheter Breakage In-Situ

    Directory of Open Access Journals (Sweden)

    Geetanjali S Verma

    2014-09-01

    Full Text Available A 45yr old woman diagnosed with dysfunctional uterine bleeding and incisional hernia was planned for total abdominal hysterectomy with bilateral salpingo-oophorectomy and mesh repair under combined spinal and epidural anaesthesia. Using VYGON® epidural catheter with its recommended introducer, the catheter was inserted but it snapped off at 11cm mark while positioning the catheter. After radiological confirmation, the neurosurgeon removed the catheter under general anaesthesia, which was followed by the scheduled surgery.

  8. Isatis tinctoria L. combined with co-stimulatory molecules blockade prolongs survival of cardiac allografts in alloantigen-primed mice.

    Science.gov (United States)

    Kang, Xiangpeng; Chen, Jibing; Qin, Qing; Wang, Feng; Wang, Yongzhi; Lan, Tianshu; Xu, Shuo; Wang, Feiyu; Xia, Junjie; Ekberg, Henrik; Qi, Zhongquan; Liu, Zhongchen

    2010-05-01

    Memory T cells present a unique challenge in transplantation. Although memory T cells express robust immune responses to invading pathogens, they may be resistant to the effects of immunosuppressive therapies used to prolong graft survival. In previous studies, we found that compound K, the synthesized analogue of highly unsaturated fatty acids from Isatis tinctoria L., reduced acute cardiac allograft rejection in mice (Wang et al., 2009 [1]). Here, we further investigated the effect of compound K on cardiac allograft rejection in alloantigen-primed mice. We found that compound K significantly inhibited CD4(+) and CD8(+) memory T cells proliferation in a mixed lymphocyte reaction (MLR). In vivo, compound K combined with anti-CD154 and anti-LFA-1 monoclonal antibodies (mAbs) significantly extended the survival time of heart grafts in alloantigen-primed mice with no obvious toxic side effects. Furthermore, our data suggests that compound K works by reducing the expression of both IL-2 and IFN-gamma within the graft rather than enhancing expression of regulatory T cells (Tregs). Compound K can also inhibit the alloresponses of memory T cells, while increasing the proportion of CD4(+) memory T cells in the spleen of the recipients and significantly reducing the level of alloantibodies in the serum. Our study highlights the unique immune effects of compound K that may be further explored for clinical use in extending the survival of transplant grafts. Copyright (c) 2010 Elsevier B.V. All rights reserved.

  9. Systemic treatment with CAR-engineered T cells against PSCA delays subcutaneous tumor growth and prolongs survival of mice

    International Nuclear Information System (INIS)

    Hillerdal, Victoria; Ramachandran, Mohanraj; Leja, Justyna; Essand, Magnus

    2014-01-01

    Adoptive transfer of T cells genetically engineered with a chimeric antigen receptor (CAR) has successfully been used to treat both chronic and acute lymphocytic leukemia as well as other hematological cancers. Experimental therapy with CAR-engineered T cells has also shown promising results on solid tumors. The prostate stem cell antigen (PSCA) is a protein expressed on the surface of prostate epithelial cells as well as in primary and metastatic prostate cancer cells and therefore a promising target for immunotherapy of prostate cancer. We developed a third-generation CAR against PSCA including the CD28, OX-40 and CD3 ζ signaling domains. T cells were transduced with a lentivirus encoding the PSCA-CAR and evaluated for cytokine production (paired Student’s t-test), proliferation (paired Student’s t-test), CD107a expression (paired Student’s t-test) and target cell killing in vitro and tumor growth and survival in vivo (Log-rank test comparing Kaplan-Meier survival curves). PSCA-CAR T cells exhibit specific interferon (IFN)-γ and interleukin (IL)-2 secretion and specific proliferation in response to PSCA-expressing target cells. Furthermore, the PSCA-CAR-engineered T cells efficiently kill PSCA-expressing tumor cells in vitro and systemic treatment with PSCA-CAR-engineered T cells significantly delays subcutaneous tumor growth and prolongs survival of mice. Our data confirms that PSCA-CAR T cells may be developed for treatment of prostate cancer

  10. Incidence of catheter-related complications in patients with central venous or hemodialysis catheters: a health care claims database analysis.

    Science.gov (United States)

    Napalkov, Pavel; Felici, Diana M; Chu, Laura K; Jacobs, Joan R; Begelman, Susan M

    2013-10-16

    Central venous catheter (CVC) and hemodialysis (HD) catheter usage are associated with complications that occur during catheter insertion, dwell period, and removal. This study aims to identify and describe the incidence rates of catheter-related complications in a large patient population in a United States-based health care claims database after CVC or HD catheter placement. Patients in the i3 InVision DataMart® health care claims database with at least 1 CVC or HD catheter insertion claim were categorized into CVC or HD cohorts using diagnostic and procedural codes from the US Renal Data System, American College of Surgeons, and American Medical Association's Physician Performance Measures. Catheter-related complications were identified using published diagnostic and procedural codes. Incidence rates (IRs)/1000 catheter-days were calculated for complications including catheter-related bloodstream infections (CRBSIs), thrombosis, embolism, intracranial hemorrhage (ICH), major bleeding (MB), and mechanical catheter-related complications (MCRCs). Thirty percent of the CVC cohort and 54% of the HD cohort had catheter placements lasting <90 days. Catheter-related complications occurred most often during the first 90 days of catheter placement. IRs were highest for CRBSIs in both cohorts (4.0 [95% CI, 3.7-4.3] and 5.1 [95% CI, 4.7-5.6], respectively). Other IRs in CVC and HD cohorts, respectively, were thrombosis, 1.3 and 0.8; MCRCs, 0.6 and 0.7; embolism, 0.4 and 0.5; MB, 0.1 and 0.3; and ICH, 0.1 in both cohorts. Patients with cancer at baseline had significantly higher IRs for CRBSIs and thrombosis than non-cancer patients. CVC or HD catheter-related complications were most frequently seen in patients 16 years or younger. The risk of catheter-related complications is highest during the first 90 days of catheter placement in patients with CVCs and HD catheters and in younger patients (≤16 years of age) with HD catheters. Data provided in this study can be applied

  11. Probability of Survival Decision Aid (PSDA)

    National Research Council Canada - National Science Library

    Xu, Xiaojiang; Amin, Mitesh; Santee, William R

    2008-01-01

    A Probability of Survival Decision Aid (PSDA) is developed to predict survival time for hypothermia and dehydration during prolonged exposure at sea in both air and water for a wide range of environmental conditions...

  12. Vascular access in neonatology: peripherally inserted central catheter and peripheral venous catheter

    Directory of Open Access Journals (Sweden)

    Marcia Lienemann

    2014-04-01

    The objective of this paper is to present aspects of peripherally inserted central catheter and peripheral venous catheter, highlighting important points in choosing the type of access. For the passage of peripherally inserted central catheter is previously performing specific course necessary, while the primary indication occurs when it is necessary to access the patient's stay for a long period of time. Whereas peripheral venipuncture is the most appropriate in cases of needing an IV line quickly and safely, for the administration of fluids, blood collection, blood transfusion and other.

  13. Ambient but not local lactate underlies neuronal tolerance to prolonged glucose deprivation

    Science.gov (United States)

    Sobieski, Courtney; Shu, Hong-Jin

    2018-01-01

    Neurons require a nearly constant supply of ATP. Glucose is the predominant source of brain ATP, but the direct effects of prolonged glucose deprivation on neuronal viability and function remain unclear. In sparse rat hippocampal microcultures, neurons were surprisingly resilient to 16 h glucose removal in the absence of secondary excitotoxicity. Neuronal survival and synaptic transmission were unaffected by prolonged removal of exogenous glucose. Inhibition of lactate transport decreased microculture neuronal survival during concurrent glucose deprivation, suggesting that endogenously released lactate is important for tolerance to glucose deprivation. Tandem depolarization and glucose deprivation also reduced neuronal survival, and trace glucose concentrations afforded neuroprotection. Mass cultures, in contrast to microcultures, were insensitive to depolarizing glucose deprivation, a difference attributable to increased extracellular lactate levels. Removal of local astrocyte support did not reduce survival in response to glucose deprivation or alter evoked excitatory transmission, suggesting that on-demand, local lactate shuttling is not necessary for neuronal tolerance to prolonged glucose removal. Taken together, these data suggest that endogenously produced lactate available globally in the extracellular milieu sustains neurons in the absence of glucose. A better understanding of resilience mechanisms in reduced preparations could lead to therapeutic strategies aimed to bolster these mechanisms in vulnerable neuronal populations. PMID:29617444

  14. Emergency coronary angioplasty with stenting using Cordis® diagnostic coronary catheters when there is difficulty in engaging guide catheters and bench evaluation of diagnostic and guide catheters.

    Science.gov (United States)

    Arokiaraj, Mark Christopher

    2018-02-01

    Difficulty in engaging with guide catheters is not uncommon in acute emergencies. We aimed to evaluate the use of Cordis ® INFINITI diagnostic catheters to perform angioplasty in patients in whom the coronaries cannot be engaged using standard guide catheters. In 34 cases of acute coronary syndrome, when difficulty in engagement with two standard guide catheters was encountered with reasonable manipulations, angioplasty was performed using diagnostic catheters. In total, 40 stents were placed by this technique. Pushability and trackability, distal tip flexion and three-point bending tests were performed to evaluate the performance of the guide and diagnostic catheters. Angioplasty was performed easily in a setting where it would have been very difficult to perform. Coronary dissection occurred in one patient, treated by a stent. The stent and dilatation balloons were easily passed through the diagnostic catheters. Pressure tracings were clearly preserved with certain stent delivery systems, and at angioplasty, although there was slightly reduced opacification of the respective artery, the coronary anatomy was sufficiently visualized to perform angioplasty. No periprocedural target lesion complications were seen in any cases. Pushability and trackability tests showed good force transmission along a tortuous path with diagnostic catheters, and balanced force-displacement curves from three-point bending tests and distal tip softness tests. Angioplasty with stenting can be performed safely through 6F Cordis ® infiniti diagnostic catheters when difficulty in engaging guide catheters is encountered. Copyright © 2018 Sociedade Portuguesa de Cardiologia. Publicado por Elsevier España, S.L.U. All rights reserved.

  15. Intracorporeal knotting of a femoral nerve catheter

    Directory of Open Access Journals (Sweden)

    Ghanem, Mohamed

    2015-01-01

    Full Text Available Peripheral nerve catheters are effective and well-established tools to provide postoperative analgesia to patients undergoing orthopedic surgery. The performance of these techniques is usually considered safe. However, placement of nerve catheters may be associated with a considerable number of side effects and major complications have repeatedly been published. In this work, we report on a patient who underwent total knee replacement with spinal anesthesia and preoperative insertion of femoral and sciatic nerve catheters for postoperative analgesia. During insertion of the femoral catheter, significant resistance was encountered upon retracting the catheter. This occurred due to knotting of the catheter. The catheter had to be removed by operative intervention which has to be considered a major complication. The postoperative course was uneventful. The principles for removal of entrapped peripheral catheters are not well established, may differ from those for neuroaxial catheters, and range from cautious manipulation up to surgical intervention.

  16. Radiologic placement of Hickman catheters

    International Nuclear Information System (INIS)

    Robertson, L.J.; Mauro, M.A.; Jaques, P.F.

    1988-01-01

    Hickman catheter inserter has previously been predominantly accomplished surgically by means of venous cutdown or percutaneous placement in the operating room. The authors describe their method and results for 55 consecutive percutaneous placements of Hickman catheters in the interventional radiology suite. Complication rates were comparable to those for surgical techniques. Radiologic placement resulted in increased convenience, decreased time and cost of insertion, and super fluoroscopic control of catheter placement and any special manipulations. Modern angiographic materials provide safer access to the subclavian vein than traditional methods. The authors conclude that radiologic placement of Hickman catheters offers significant advantages over traditional surgical placement

  17. Comparative study of peripherally inserted central venous catheter and traditional central catheter assisted with X-ray

    International Nuclear Information System (INIS)

    Yu Jianchun; Wang Xiurong; Jiang Zhuming

    1999-01-01

    Objective: To study the feasibility, complications, mid- and long-term advantages of peripherally inserted central catheters (PICC) compared with central venous access assisted with X-ray. Methods: From Jan 1997 to Dec 1998, the authors conducted a study in 60 patients with placed PICC lines and 60 patients with central lines. Study variables included tip placement and complication rates. Results: Tere were on significant differences between PICC and CVC in the successful placement 95.0% and 88.3%, t = 1.745, P 0.19; the mean duration 13(6-98) days and 14 (7-104) days, F = 0.049, P = 0.83; the total occlusion rate 6.7% (4/60) and 5.0%(3/60), t = 0.152, P = 0.70. In PICC patients, the occlusion rate was slightly higher in 3 Fr (20-gauge) catheter (3/20, 15.0%) than in 4 Fr(18-gauge) catheters (1/20, 5.0%), t = 1.111, P=0.29. Phlebitis occurred in 5.0% of patients (3/60) and one catheter fracture was happened on the catheter hub junction (1.7%). In 3 catheter tips dislocation cases, the catheter tips were moved to the optional position assisted with X-ray image. In CVC group, pneumothorax happened in 1 case (1.7%). In 4 catheter dislocation cases, the catheters were with drawn. No catheter-related sepsis and hemo-pneumothorax happened in both group patients. Conclusions: Both PICC and CVC can be acceptable in clinical use. PICC assisted with X-ray possesses the advantages of less trauma, accurate localization preventing some possible severe complications of central venous access such as pneumothorax. The new method provides a reliable, effective venous access for mid-and long-term usage in patients receiving a variety of solutions, primarily parenteral alimentation, chemotherapy or antibiotic infusion

  18. Incidence, risk factors, microbiology of venous catheter associated bloodstream infections - A prospective study from a tertiary care hospital

    Directory of Open Access Journals (Sweden)

    M Kaur

    2015-01-01

    Full Text Available Purpose : Central venous catheters (CVCs though indispensable in current medical and intensive care treatment, also puts patients at risk of catheter related infection (CRI resulting in increased morbidity and mortality. We analysed the incidence, risk factors, bacteriological profile and antimicrobial susceptibility pattern of the isolates in central venous catheter associated bloodstream infection (CVC-BSI in the intensive care unit (ICU patients and studied the formation of biofilm in CVCs. Materials and Methods: The following case control study included 115 patients with CVC in situ. Quantitative blood cultures (QBC and catheter tip cultures were performed for the diagnoses. Direct catheter staining was done for an early diagnosis by acridine orange (AO and Gram staining methods. Biofilm production in catheters was detected by ′tissue culture plate′ (TCP method. The results were analysed using the computer-based program statistical package for the social sciences (SPSS. Results : In 25/115 patients, definite diagnosis of CVC-BSI was made. The mean age was 48.44 ± 17.34 years (cases vs 40.10 ± 18.24 years (controls and the mean duration of catheterisation was 25.72 ± 8.73 days (cases vs 11.89 ± 6.38 days (controls. Local signs of infection (erythema, tenderness and oozing were found more significantly in CVC-BSI cases. The AO staining was more sensitive and Gram staining of catheters showed higher specificity. Staphylococcus aureus followed by Pseudomonas aeruginosa and non-albicans Candida were common CVC-BSI pathogens. Multidrug-resistant (MDR strains were isolated in bacterial agents of CVC-BSI. Non-albicans Candida and Enterococcus faecalis showed strong biofilm production. Conclusion : The incidence of CVC-BSI was 21.73% and the rate was 14.59 per 1000 catheter days. Prolonged ICU stay and longer catheterisation were major risk factors. S. aureus was isolated most commonly in CVC-BSI cases. The menace of multidrug resistance and

  19. Unplanned Start on Peritoneal Dialysis Right after PD Catheter Implantation for Older People with End-Stage Renal Disease.

    Science.gov (United States)

    Povlsen, Johan V; Sørensen, Anette Bagger; Ivarsen, Per

    2015-11-01

    Unplanned start on dialysis remains a major problem for the dialysis community worldwide. Late-referred patients with end-stage renal disease (ESRD) and urgent need for dialysis are overrepresented among older people. These patients are particularly likely to be started on in-center hemodialysis (HD), with a temporary vascular access known to be associated with excess mortality and increased risks of potentially lethal complications such as bacteremia and central venous thrombosis or stenosis.The present paper describes in detail our program for unplanned start on automated peritoneal dialysis (APD) right after PD catheter implantation and summarizes our experiences with the program so far. Compared with planned start on PD after at least 2 weeks of break-in between PD catheter implantation and initiation of dialysis, unplanned start may be associated with a slight increased risk of mechanical complications but apparently no detrimental effect on mortality, peritonitis-free survival, or PD technique survival.In our opinion and experience, the risk of serious complications associated with the implantation and immediate use of a PD catheter is less than the risk of complications associated with unplanned start on HD with a temporary central venous catheter (CVC). Unplanned start on APD is a gentle, safe, and feasible alternative to unplanned start on HD with a temporary CVC that is also valid for the late-referred older patient with ESRD and urgent need for dialysis. Copyright © 2015 International Society for Peritoneal Dialysis.

  20. Coronary angioplasty with second generation Monorail catheters.

    Science.gov (United States)

    Pande, A K; Meier, B; Urban, P; Villavicencio, R; de la Serna, F; Moles, V

    1991-07-01

    The Monorail system (Schneider) consists of a balloon catheter in which the guidewire passes through the balloon itself, exits the catheter proximal to the balloon, and runs alongside its small shaft (3 French) through the length of the guiding catheter. It offers distinct advantages over conventional systems of coronary angioplasty. It facilitates contrast injections and permits rapid balloon exchanges. This system was used for coronary angioplasty in 273 unselected consecutive patients (age 59 +/- 10, mean 35 to 73 years). There were 216 patients (84%) undergoing single-vessel and 57 patients (16%) with multi-vessel coronary angioplasty. A total of 335 coronary stenoses were dilated, which included 35 total occlusions. The size of balloon used ranged from 2.0 to 4.25 mm (3.0 +/- 0.5 mm) and the severity of stenosis was 85 +/- 11%. Technical success was defined as a residual stenosis of less than 50% as determined angiographically. Clinical success was defined as technical success, and absence of a major inhospital complication defined as absence of myocardial infarction, lack of need for coronary arterial bypass surgery, and survival. The Monorail system was technically successful in 294/300 stenotic lesions (98%). It was clinically successful for 281 lesions (94%). Of the 35 total occlusions, technical success was obtained in 25 (71%). The residual stenosis of successful cases was 26 +/- 21%. The Monorail system was also successful in 5 patients with stenosis of more than 90% in whom conventional systems failed. The complications included acute occlusion causing acute myocardial infarction in 13 cases (5%), emergency coronary arterial bypass surgery in 1 patient (0.4%), and death in 4 patients (1.5%).(ABSTRACT TRUNCATED AT 250 WORDS)

  1. [Incidence of phlebitis due to peripherally inserted venous catheters: impact of a catheter management protocol].

    Science.gov (United States)

    Ferrete-Morales, C; Vázquez-Pérez, M A; Sánchez-Berna, M; Gilabert-Cerro, I; Corzo-Delgado, J E; Pineda-Vergara, J A; Vergara-López, S; Gómez-Mateos, J

    2010-01-01

    To assess the impact on the incidence of PPIVC by implementing a catheter management protocol and to determine risk factors for PPIVC development in hospitalized patients. A total of 3978 episodes of venous catheterization were prospectively included from September 2002 to December 2007. A catheter management protocol was implemented during this period of time. The incidence and variables associated to the occurrence of PPIVC were determined. The incidence of PPIVC from 2002 to 2007 was 4.8%, 4.3%, 3.6%, 2.5%, 1.3% and 1.8% (phistory of phlebitis was the only factor independently associated to phlebitis due to peripherally inserted central venous catheters (AOR 3.24; CI at 95% CI= 1.05-9.98, p=0.04). A catheter management protocol decreases the incidence of PPIVC in hospitalized patients. The risk of PPIVC increases for peripherally inserted central venous catheters when the patients have a history of phlebitis and for peripheral venous catheters when amiodarone or cefotaxime are infused. Catheterization of peripheral veins performed during morning shifts is associated with a lower incidence of PPIVC when compared with night shift catheterizations.

  2. Effect of blood transfusions on canine renal allograft survival

    International Nuclear Information System (INIS)

    Van Der Linden, C.J.; Buurman, W.A.; Vegt, P.A.; Greep, J.M.; Jeekel, J.

    1982-01-01

    In this study significantly prolonged canine renal allograft survival has been demonstrated after transfusion of 100 ml of third-party whole blood given peroperatively. Peroperative transfusions of third-party leukocyte-free blood or pure lymphocyte cell suspensions did not influence graft survival. Futhermore, no improvement in graft survival has been found after a peroperative transfuson of irradiated whole blood (2500 rad). These data suggest that delayed graft rejection after blood transfusions can only be expected after the administration of whole blood. The role of competent lymphocytes in whole blood is questionable, since a transfusion of irradiated whole blood in combination with nonirradiated lymphocytes did not lead to prolonged graft survival. Immunosuppression of the recipient directly after transfusion seems to be essential to induce the beneficial effect of blood transfusions. This has been demonstrated for a transfusion of whole blood 14 days before transplantation. A single transfusion of 100 ml of whole blood 14 days before transplantation could effectively prolong graft survival if immunosuppression with azathioprine and prednisone was started on the day of transfusion. No improvement in graft survival has been found with such a transfusion if preoperative immunosuppression has been omitted

  3. Effect of blood transfusions on canine renal allograft survival

    International Nuclear Information System (INIS)

    van der Linden, C.J.; Buurman, W.A.; Vegt, P.A.; Greep, J.M.; Jeekel, J.

    1982-01-01

    In this study significantly prolonged canine renal allograft survival has been demonstrated after transfusion of 100 ml of third-party whole blood given peroperatively. Peroperative transfusions of third-party leukocyte-free blood or pure lymphocyte cell suspensions did not influence graft survival. Furthermore, no improvement in graft survival has been found after a peroperative transfusion of irradiated whole blood (2500 rad). These data suggest that delayed graft rejection after blood transfusions can only be expected after the administration of whole blood. The role of competent lymphocytes in whole blood is questionable, since a transfusion or irradiated whole blood in combination with nonirradiated lymphocytes did not lead to prolonged graft survival. Immunosuppression of the recipient directly after transfusion seems to be essential to induce the beneficial effect of blood transfusions. This has been demonstrated for a transfusion of whole blood 14 days before transplantation. A single transfusion of 100 ml of whole blood 14 days before transplantation could effectively prolong graft survival if immunosuppression with azathioprine and prednisone was started on the day of transfusion. No improvement in graft survival has been found with such a transfusion if preoperative immunosuppression has been omitted

  4. The effect of peripherally inserted central catheter (PICC) valve technology on catheter occlusion rates--the 'ELeCTRiC' study.

    Science.gov (United States)

    Johnston, Andrew J; Streater, Carmel T; Noorani, Remy; Crofts, Joanne L; Del Mundo, Aldwin B; Parker, Richard A

    2012-01-01

    Peripherally Inserted Central Catheters (PICCs) are increasingly being used to provide short to medium-term central venous access. The current study was designed to test the hypothesis that PICC valve technology does not influence PICC occlusion rates. Intensive care unit (ICU) patients who required a PICC were randomized to one of three types of dual lumen PICC (open ended non-valved, Groshong valve, PASV valve). PICC occlusions were recorded and managed with a protocol that used urokinase. A total of 102 patients were recruited to the study. The overall risk of occlusion per catheter was 35% (95% CI 26% to 44%). The overall rate of occlusion was 76 occlusions per 1000 catheter days (95% CI 61 to 95). Presence or type of valve did not significantly influence this rate (open-ended non-valved PICC 38% of catheters, 79 occlusions per 1000 catheter days; Groshong 38% of catheters, 60 occlusions per 1000 catheter days; PASV 27% of catheters, 99 occlusions per 1000 catheter days). The dose of urokinase required to treat PICC occlusions did not significantly differ between PICC types. Valved PICCs do not appear to influence PICC occlusion rates.

  5. In vitro analysis of balloon cuffing phenomenon: inherent biophysical properties of catheter material or mechanics of catheter balloon deflation?

    Science.gov (United States)

    Chung, Eric; So, Karina

    2012-06-01

    To investigates the different methods of balloon deflation, types of urinary catheters and exposure to urine media in catheter balloon cuffing. Bardex®, Bard-Lubri-Sil®, Argyle®, Releen® and Biocath® were tested in sterile and E.Coli inoculated urine at 0, 14 and 28 days. Catheter deflation was performed with active deflation; passive deflation; passive auto-deflation; and excision of the balloon inflow channel. Balloon cuffing was assessed objectively by running the deflated balloon over a plate of agar and subjectively by 3 independent observers. Bardex®, Argyle® and Biocath® showed greater degree of catheter balloon cuffing (p deflation was the worst method (p 0.05). Linear regression model analysis confirmed time as the most significant factor. The duration of catheters exposure, different deflation methods and types of catheters tested contributed significantly to catheter balloon cuffing (p < 0.01).

  6. Prevention of catheter-related blood stream infection.

    Science.gov (United States)

    Byrnes, Matthew C; Coopersmith, Craig M

    2007-08-01

    Catheter-related blood stream infections are a morbid complication of central venous catheters. This review will highlight a comprehensive approach demonstrated to prevent catheter-related blood stream infections. Elements of prevention important to inserting a central venous catheter include proper hand hygiene, use of full barrier precautions, appropriate skin preparation with 2% chlorhexidine, and using the subclavian vein as the preferred anatomic site. Rigorous attention needs to be given to dressing care, and there should be daily assessment of the need for central venous catheters, with prompt removal as soon as is practicable. Healthcare workers should be educated routinely on methods to prevent catheter-related blood stream infections. If rates remain higher than benchmark levels despite proper bedside practice, antiseptic or antibiotic-impregnated catheters can also prevent infections effectively. A recent program utilizing these practices in 103 ICUs in Michigan resulted in a 66% decrease in infection rates. There is increasing recognition that a comprehensive strategy to prevent catheter-related blood stream infections can prevent most infections, if not all. This suggests that thousands of infections can potentially be averted if the simple practices outlined herein are followed.

  7. Adjuvant Hepatic Arterial Infusion Chemotherapy After Resection for Pancreatic Cancer Using Coaxial Catheter-Port System Compared with Conventional System

    International Nuclear Information System (INIS)

    Hashimoto, Aya; Tanaka, Toshihiro; Sho, Masayuki; Nishiofuku, Hideyuki; Masada, Tetsuya; Sato, Takeshi; Marugami, Nagaaki; Anai, Hiroshi; Sakaguchi, Hiroshi; Kanno, Masatoshi; Tamamoto, Tetsuro; Hasegawa, Masatoshi; Nakajima, Yoshiyuki; Kichikawa, Kimihiko

    2016-01-01

    PurposePrevious reports have shown the effectiveness of adjuvant hepatic arterial infusion chemotherapy (HAIC) in pancreatic cancer. However, percutaneous catheter placement is technically difficult after pancreatic surgery. The purpose of this study was to evaluate the feasibility and outcome of HAIC using a coaxial technique compared with conventional technique for postoperative pancreatic cancer.Materials and Methods93 consecutive patients who received percutaneous catheter-port system placement after pancreatectomy were enrolled. In 58 patients from March 2006 to August 2010 (Group A), a conventional technique with a 5-Fr indwelling catheter was used and in 35 patients from September 2010 to September 2012 (Group B), a coaxial technique with a 2.7-Fr coaxial catheter was used.ResultsThe overall technical success rates were 97.1 % in Group B and 86.2 % in Group A. In cases with arterial tortuousness and stenosis, the success rate was significantly higher in Group B (91.7 vs. 53.8 %; P = 0.046). Fluoroscopic and total procedure times were significantly shorter in Group B: 14.7 versus 26.7 min (P = 0.001) and 64.8 versus 80.7 min (P = 0.0051), respectively. No differences were seen in the complication rate. The 1 year liver metastasis rates were 9.9 % using the conventional system and 9.1 % using the coaxial system (P = 0.678). The overall median survival time was 44 months. There was no difference in the survival period between two systems (P = 0.312).ConclusionsThe coaxial technique is useful for catheter placement after pancreatectomy, achieving a high success rate and reducing fluoroscopic and procedure times, while maintaining the safety and efficacy for adjuvant HAIC in pancreatic cancer.

  8. Adjuvant Hepatic Arterial Infusion Chemotherapy After Resection for Pancreatic Cancer Using Coaxial Catheter-Port System Compared with Conventional System

    Energy Technology Data Exchange (ETDEWEB)

    Hashimoto, Aya; Tanaka, Toshihiro, E-mail: toshihir@bf6.so-net.ne.jp [Nara Medical University, Department of Radiology (Japan); Sho, Masayuki [Nara Medical University, Department of Surgery (Japan); Nishiofuku, Hideyuki; Masada, Tetsuya; Sato, Takeshi; Marugami, Nagaaki [Nara Medical University, Department of Radiology (Japan); Anai, Hiroshi [Nara City Hospital, Department of Radiology (Japan); Sakaguchi, Hiroshi [Nara Prefectural Western Medical Center, Department of Radiology (Japan); Kanno, Masatoshi [Nara Medical University, Oncology Center (Japan); Tamamoto, Tetsuro; Hasegawa, Masatoshi [Nara Medical University, Department of Radiation Oncology (Japan); Nakajima, Yoshiyuki [Nara Medical University, Department of Surgery (Japan); Kichikawa, Kimihiko [Nara Medical University, Department of Radiology (Japan)

    2016-06-15

    PurposePrevious reports have shown the effectiveness of adjuvant hepatic arterial infusion chemotherapy (HAIC) in pancreatic cancer. However, percutaneous catheter placement is technically difficult after pancreatic surgery. The purpose of this study was to evaluate the feasibility and outcome of HAIC using a coaxial technique compared with conventional technique for postoperative pancreatic cancer.Materials and Methods93 consecutive patients who received percutaneous catheter-port system placement after pancreatectomy were enrolled. In 58 patients from March 2006 to August 2010 (Group A), a conventional technique with a 5-Fr indwelling catheter was used and in 35 patients from September 2010 to September 2012 (Group B), a coaxial technique with a 2.7-Fr coaxial catheter was used.ResultsThe overall technical success rates were 97.1 % in Group B and 86.2 % in Group A. In cases with arterial tortuousness and stenosis, the success rate was significantly higher in Group B (91.7 vs. 53.8 %; P = 0.046). Fluoroscopic and total procedure times were significantly shorter in Group B: 14.7 versus 26.7 min (P = 0.001) and 64.8 versus 80.7 min (P = 0.0051), respectively. No differences were seen in the complication rate. The 1 year liver metastasis rates were 9.9 % using the conventional system and 9.1 % using the coaxial system (P = 0.678). The overall median survival time was 44 months. There was no difference in the survival period between two systems (P = 0.312).ConclusionsThe coaxial technique is useful for catheter placement after pancreatectomy, achieving a high success rate and reducing fluoroscopic and procedure times, while maintaining the safety and efficacy for adjuvant HAIC in pancreatic cancer.

  9. Cefotaxime-heparin lock prophylaxis against hemodialysis catheter-related sepsis among Staphylococcus aureus nasal carriers

    Directory of Open Access Journals (Sweden)

    Anil K Saxena

    2012-01-01

    Full Text Available Staphylococcus aureus nasal carriers undergoing hemodialysis (HD through tunneled cuffed catheters (TCCs form a high-risk group for the development of catheter-related bloodstream infections (CRBSI and ensuing morbidity. The efficacy of antibiotic-locks on the outcomes of TCCs among S. aureus nasal carriers has not been studied earlier. Persistent nasal carriage was defined by two or more positive cultures for methicillin-susceptible (MSSA or methicillin-resistant (MRSA S. aureus of five standardized nasal swabs taken from all the participants dialyzed at a large out-patient HD center affiliated to a tertiary care hospital. Of 218 participants, 82 S. aureus nasal carriers dialyzed through TCCs (n = 88 were identified through April 2005 to March 2006 and randomized to two groups. Group I comprised of 39 nasal carriers who had TCCs (n = 41 "locked" with cefotaxime/heparin while group II included 43 patients with TCCs (n = 47 filled with standard heparin. The CRBSI incidence and TCC survival at 365 days were statistically compared between the two groups. A significantly lower CRBSI incidence (1.47 vs. 3.44/1000 catheter-days, P <0.001 and higher infection-free TCC survival rates at 365 days (80.5 vs. 40.4%, P <0.0001 were observed in the cefotaxime group compared with the stan-dard heparin group. However, no significant difference in MRSA-associated CRBSI incidence was observed between the two groups. Cefotaxime-heparin "locks" effectively reduced CRBSI-incidence associated with gram-positive cocci, including MSSA, among S. aureus nasal carriers. There remains a compelling requirement for antibiotic-locks effective against MRSA.

  10. Prognostic Significance Of QT Interval Prolongation In Adult ...

    African Journals Online (AJOL)

    Prognostic survival studies for heart-rate corrected QT interval in patients with chronic heart failure are few; although these patients are known to have a high risk of sudden cardiac death. This study was aimed at determining the mortality risk associated with prolonged QTc in Nigerians with heart failure. Ninety-six ...

  11. Conversion from temporary to tunneled catheters by nephrologists: report of a single-center experience

    Directory of Open Access Journals (Sweden)

    Silva BC

    2016-04-01

    Full Text Available Bruno C Silva, Camila E Rodrigues, Regina CRM Abdulkader, Rosilene M Elias Nephrology Division, Hospital das Clínicas, University of São Paulo, São Paulo, Brazil Background: Nephrologists have increasingly participated in the conversion from temporary catheters (TC to tunneled-cuffed catheters (TCCs for hemodialysis. Objective: To prospectively analyze the outcomes associated with TCC placement by nephrologists with expertise in such procedure, in different time periods at the same center. The impact of vancomycin or cefazolin as prophylactic antibiotics on the infection outcomes was also tested. Patients and methods: Hemodialysis patients who presented to such procedure were divided into two cohorts: A (from 2004 to 2008 and B (from 2013 to 2015. Time from TC to TCC conversion, prophylactic antibiotics, and reasons for TCC removal were evaluated. Results: One hundred and thirty patients were included in cohort A and 228 in cohort B. Sex, age, and follow-up time were similar between cohorts. Median time from TC to TCC conversion was longer in cohort A than in cohort B (14 [3; 30] vs 4 [1; 8] days, respectively; P<0.0001. Infection leading to catheter removal occurred in 26.4% vs 18.9% of procedures in cohorts A and B, respectively, and infection rate was 0.93 vs 0.73 infections per 1,000 catheter-days, respectively (P=0.092. Infection within 30 days from the procedure occurred in 1.4% of overall cohort. No differences were observed when comparing vancomycin and cefazolin as prophylactic antibiotics on 90-day infection-free TCC survival in a Kaplan–Meier model (log-rank = 0.188. TCC removal for low blood flow occurred in 8.9% of procedures. Conclusion: Conversion of TC to TCC by nephrologists had overall infection, catheter patency, and complications similar to data reported in the literature. Vancomycin was not superior to cefazolin as a prophylactic antibiotic. Keywords: renal dialysis, tunneled catheters, interventional nephrology

  12. Usefulness of gram staining of blood collected from total parenteral nutrition catheter for rapid diagnosis of catheter-related sepsis.

    Science.gov (United States)

    Moonens, F; el Alami, S; Van Gossum, A; Struelens, M J; Serruys, E

    1994-01-01

    The accuracy of Gram staining of blood drawn from catheters used to administer total parenteral nutrition was compared with paired quantitative blood cultures for the diagnosis of catheter-related sepsis. Gram staining was positive in 11 of 18 episodes of catheter-related sepsis documented by quantitative culture (sensitivity, 61%) but in none of the 5 episodes of fever unrelated to catheter infection. Thus, this procedure enabled the rapid presumptive diagnosis and guidance of antimicrobial therapy for total parenteral nutrition catheter sepsis, with a positive predictive value of 100% and a negative predictive value of 42%. PMID:7521359

  13. [Peripheral intravenous catheter-related phlebitis].

    Science.gov (United States)

    van der Sar-van der Brugge, Simone; Posthuma, E F M Ward

    2011-01-01

    Phlebitis is a very common complication of the use of intravenous catheters. Two patients with an i.v. catheter complicated by thrombophlebitis are described. Patient A was immunocompromised due to chronic lymphatic leukaemia and developed septic thrombophlebitis with positive blood cultures for S. Aureus. Patient B was being treated with flucloxacillin because of an S. Aureus infection and developed chemical phlebitis. Septic phlebitis is rare, but potentially serious. Chemical or mechanical types of thrombophlebitis are usually less severe, but happen very frequently. Risk factors include: female sex, previous episode of phlebitis, insertion at (ventral) forearm, emergency placement and administration of antibiotics. Until recently, routine replacement of peripheral intravenous catheters after 72-96 h was recommended, but randomised controlled trials have not shown any benefit of this routine. A recent Cochrane Review recommends replacement of peripheral intravenous catheters when clinically indicated only.

  14. Value of Micronester coils in port-catheter implantation for continuous hepatic arterial infusion chemotherapy with fixed catheter tip method

    International Nuclear Information System (INIS)

    Yamagami, Takuji; Kato, Takeharu; Hirota, Tatsuya; Yoshimatsu, Rika; Matsumoto, Tomohiro; Nishimura, Tsunehiko; White, Robert I.

    2008-01-01

    To retrospectively evaluate the use of Micronester coils in port-catheter implantation with the fixed catheter tip method in comparison with other previously used coils. The cohort of this study was 143 consecutive patients with unresectable advanced liver cancer for whom a port-catheter system was percutaneously implanted. In the most recent 32 patients, Micronester coils were used for catheter tip fixation. Details of embolic agents for fixation, persistent blood flow beyond the distal end of the indwelling catheter, and complications were compared between cases without and with Micronester coils. In all, percutaneous port-catheter placement was successful. Mean number of coils used for fixation was 4.2 without Micronester coils vs. 2.5 with Micronester coils. N-butyl cyanoacrylate (NBCA)-Lipiodol was additionally used for catheter tip fixation in 85.6% of 111 procedures without Micronester coils and in 50% of 32 using Micronester coils. The gastroduodenal artery beyond the distal end was not detected at the final examination after any procedure. Catheter dislocation occurred in five and hepatic arterial obstruction or severe stenosis in eight. The number of coils used and necessity of NBCA-Lipiodol could be decreased with usage of Micronester coils without decreasing fixation ability compared to other coils. (orig.)

  15. 21 CFR 868.5120 - Anesthesia conduction catheter.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Anesthesia conduction catheter. 868.5120 Section... (CONTINUED) MEDICAL DEVICES ANESTHESIOLOGY DEVICES Therapeutic Devices § 868.5120 Anesthesia conduction catheter. (a) Identification. An anesthesia conduction catheter is a flexible tubular device used to inject...

  16. Agile and Bright Intracardiac Catheters

    NARCIS (Netherlands)

    M. Pekař (Martin)

    2017-01-01

    markdownabstractIntracardiac imaging catheters represent unique instruments to diagnose and treat a diseased heart. While there are imminent advances in medical innovation, many of the commercially available imaging catheters are outdated. Some of them have been designed more than 20 years and

  17. Effect of prolonging radiation delivery time on retention of gammaH2AX

    International Nuclear Information System (INIS)

    Moiseenko, Vitali; Banáth, Judit P; Duzenli, Cheryl; Olive, Peggy L

    2008-01-01

    Compared to conventional external beam radiotherapy, IMRT requires significantly more time to deliver the dose. Prolonging dose delivery potentially increases DNA repair which would reduce the biological effect. We questioned whether retention of γH2AX, a measure of lack of repair of DNA damage, would decrease when dose delivery was protracted. Exponentially growing SiHa cervical carinoma cells were irradiated with 6 MV photons in a water tank using a VarianEX linear accelerator. Cells held at 37°C received 2 Gy in 0.5 min and 4 Gy in 1 min. To evaluate effect of dose delivery prolongation, 2 and 4 Gy were delivered in 30 and 60 min. After 24 h recovery, cells were analyzed for clonogenic survival and for residual γH2AX as measured using flow cytometry. Increasing the dose delivery time from 0.5 or 1 min to 30 or 60 min produced a signficant increase in cell survival from 0.45 to 0.48 after 2 Gy, and from 0.17 to 0.20 after 4 Gy. Expression of residual γH2AX decreased from 1.27 to 1.22 relative to background after 2 Gy and 1.46 to 1.39 relative to background after 4 Gy, but differences were not statistically significant. The relative differences in the slopes of residual γH2AX versus dose for acute versus prolonged irradiation bordered on significant (p = 0.055), and the magnitude of the change was consistent with the observed increase in surviving fraction. These results support the concept that DNA repair underlies the increase in survival observed when dose delivery is prolonged. They also help to establish the limits of sensitivity of residual γH2AX, as measured using flow cytometry, for detecting differences in response to irradiation

  18. 21 CFR 876.5030 - Continent ileostomy catheter.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Continent ileostomy catheter. 876.5030 Section 876...) MEDICAL DEVICES GASTROENTEROLOGY-UROLOGY DEVICES Therapeutic Devices § 876.5030 Continent ileostomy catheter. (a) Identification. A continent ileostomy catheter is a flexible tubular device used as a form...

  19. FAQs about Catheter-Associated Urinary Tract Infection

    Science.gov (United States)

    ... do so. o Avoid disconnecting the catheter and drain tube. This helps to pre - vent germs from getting into the catheter tube. o The catheter is secured to the leg to prevent pulling on the ... regularly. The drainage spout should not touch any - thing while emptying ...

  20. The dangers of long-term catheter drainage.

    Science.gov (United States)

    Lowthian, P

    There are many dangers associated with long-term urinary bladder drainage by catheter. For various reasons, the choice of catheter is important, and its initial insertion can be particularly hazardous. All catheterizations should, however, be safer when there is some urine (or other fluid) in the bladder. The appropriate choice of drainage system attached to the catheter can delay bacterial invasion of the bladder. Great care is needed to prevent blockage of the system, particularly when bacteriuria is present. Recent evidence indicates that some bacteria encourage the development of encrustations, so that, in some circumstances, catheters may become blocked within 24 hours. This, together with other considerations, strongly suggests that indwelling catheters should be changed at intervals of not more than 5 days. The practical implications of this are considered, as are the benefits that may accrue. Accidental catheter traction is another danger, and some possible methods of avoiding this are discussed. Finally, the need for a new kind of drainage-bag support is highlighted.

  1. Xenograft survival in two species combinations using total-lymphoid irradiation and cyclosporine

    International Nuclear Information System (INIS)

    Knechtle, S.J.; Halperin, E.C.; Bollinger, R.R.

    1987-01-01

    Total lymphoid irradiation (TLI) has profound immunosuppressive actions and has been applied successfully to allotransplantation but not xenotransplantation. Cyclosporine (CsA) has not generally permitted successful xenotransplantation of organs but has not been used in combination with TLI. TLI and CsA were given alone and in combination to rats that were recipients of hamster or rabbit cardiac xenografts. Combined TLI and CsA prolonged survival of hamster-to-rat cardiac xenografts from three days in untreated controls to greater than 100 days in most recipients. TLI alone significantly prolonged rabbit to rat xenograft survival with doubling of survival time. However, combined treatment did not significantly prolong rabbit-to-rat cardiac xenograft survival compared with TLI alone. The hamster and rat are phylogenetically closely related. Transplants from hamsters to rat are concordant xenografts since the time course of unmodified rejection is similar to first-set rejection of allografts. Although the rabbit-to-rat transplant is also between concordant species (average survival of untreated controls: 3.2 days) the rabbit and rat are more distantly related. These results suggest that TLI is an effective immunosuppressant when applied to cardiac xenotransplants in these animal models; that the choice of species critically affects xenograft survival when TLI and/or CsA are used for immunosuppression; and that the closely related species combination tested has markedly prolonged (greater than 100 days) survival using combined TLI and CsA

  2. Prolonged hypoxia increases survival even in Zebrafish (Danio rerio showing cardiac arrhythmia.

    Directory of Open Access Journals (Sweden)

    Renate Kopp

    Full Text Available Tolerance towards hypoxia is highly pronounced in zebrafish. In this study even beneficial effects of hypoxia, specifically enhanced survival of zebrafish larvae, could be demonstrated. This effect was actually more pronounced in breakdance mutants, which phenotypically show cardiac arrhythmia. Breakdance mutants (bre are characterized by chronically reduced cardiac output. Despite an about 50% heart rate reduction, they become adults, but survival rate significantly drops to 40%. Normoxic bre animals demonstrate increased hypoxia inducible factor 1 a (Hif-1α expression, which indicates an activated hypoxic signaling pathway. Consequently, cardiovascular acclimation, like cardiac hypertrophy and increased erythrocyte concentration, occurs. Thus, it was hypothesized, that under hypoxic conditions survival might be even more reduced. When bre mutants were exposed to hypoxic conditions, they surprisingly showed higher survival rates than under normoxic conditions and even reached wildtype values. In hypoxic wildtype zebrafish, survival yet exceeded normoxic control values. To specify physiological acclimation, cardiovascular and metabolic parameters were measured before hypoxia started (3 dpf, when the first differences in survival rate occurred (7 dpf and when survival rate plateaued (15 dpf. Hypoxic animals expectedly demonstrated Hif-1α accumulation and consequently enhanced convective oxygen carrying capacity. Moreover, bre animals showed a significantly enhanced heart rate under hypoxic conditions, which reached normoxic wildtype values. This improvement in convective oxygen transport ensured a sufficient oxygen and nutrient supply and was also reflected in the significantly higher mitochondrial activity. The highly optimized energy metabolism observed in hypoxic zebrafish larvae might be decisive for periods of higher energy demand due to organ development, growth and increased activity. However, hypoxia increased survival only during a

  3. Effect of gamma-irradiation on mouse pancreatic islet-allograft survival

    International Nuclear Information System (INIS)

    Kanai, T.; Porter, J.; Gotoh, M.; Monaco, A.P.; Maki, T.

    1989-01-01

    Elimination or inactivation of lymphoid tissue in the pancreatic islet preparation achieves prolongation of islet-allograft survival. In this study we examined the effect of gamma-irradiation on mouse islet-allograft survival. In a B6AF1 isograft model, irradiation up to 2400 rad did not induce deterioration of islet function over 200 days, but greater doses caused cessation of graft function between 83 and 186 days. When DBA/2 crude islets were transplanted into B6AF1 recipients, all nonirradiated allografts were acutely rejected. Marked prolongation of allograft survival was achieved by islet irradiation with doses between 800 and 12,000 rad. With higher doses, significant numbers of allografts survived beyond the controls, but many lost function between 78 and 180 days, with none surviving greater than 200 days. Irradiation with 16,000 rad caused acute radiation damage. Because most secondary islet allografts in recipient mice that lost primary islet-graft function between 84 and 195 days survived greater than 100 days, late functional loss was probably due to the radiation injury. Combined use of recipient treatment with cyclosporin A and graft irradiation (2400 rad) achieved prolongation of DBA/2 islets in B6AF1 mice

  4. Reducing catheter-related thrombosis using a risk reduction tool centered on catheter to vessel ratio.

    Science.gov (United States)

    Spencer, Timothy R; Mahoney, Keegan J

    2017-11-01

    In vascular access practices, the internal vessel size is considered important, and a catheter to vessel ratio (CVR) is recommended to assist clinicians in selecting the most appropriate-sized device for the vessel. In 2016, new practice recommendations stated that the CVR can increase from 33 to 45% of the vessels diameter. There has been evidence on larger diameter catheters and increased thrombosis risk in recent literature, while insufficient information established on what relationship to vessel size is appropriate for any intra-vascular device. Earlier references to clinical standards and guidelines did not clearly address vessel size in relation to the area consumed or external catheter diameter. The aim of this manuscript is to present catheter-related thrombosis evidence and develop a standardized process of ultrasound-guided vessel assessment, integrating CVR, Virchow's triad phenomenon and vessel health and preservation strategies, empowering an evidence-based approach to device placement. Through review, calculation and assessment on the areas of the 33 and 45% rule, a preliminary clinical tool was developed to assist clinicians make cognizant decisions when placing intravascular devices relating to target vessel size, focusing on potential reduction in catheter-related thrombosis. Increasing the understanding and utilization of CVRs will lead to a safer, more consistent approach to device placement, with potential thrombosis reduction strategies. The future of evidence-based data relies on the clinician to capture accurate vessel measurements and device-related outcomes. This will lead to a more dependable data pool, driving the relationship of catheter-related thrombosis and vascular assessment.

  5. Low-angled peripheral intravenous catheter tip placement decreases phlebitis.

    Science.gov (United States)

    Tanabe, Hidenori; Murayama, Ryoko; Yabunaka, Koichi; Oe, Makoto; Takahashi, Toshiaki; Komiyama, Chieko; Sanada, Hiromi

    2016-11-02

    Peripheral intravenous catheters (PIVCs) are frequently removed due to phlebitis. We hypothesized that catheters made of polyurethane, which is more flexible than Teflon, would decrease phlebitis, and that flexibility could be estimated by measuring the catheter-tip angle. Ultrasonography in two groups of patients with different catheter types was then used to compare catheter-tip angles and phlebitis. Observational studies were carried out at a medical ward in a university hospital. Infusion therapy was administered to one group of patients in 2014 using Teflon catheters (control group, n = 200), and to another group of patients in 2015 using polyurethane catheters (investigational group, n = 207). The symptoms were assessed according to a scale developed by the Infusion Nurses Society. Long-axis ultrasonography images taken immediately before catheter removal were used to measure the angle between the central line of the catheter within 2 mm from the distal point and a tangent to the vessel wall. There were no significant differences between the two groups with respect to sex, age, and medical diagnosis. In the control and investigational groups, the rates of phlebitis were 37% (73/200) and 17% (36/207), respectively (pPhlebitis occurred more frequently when the catheter-tip was placed at angle >5.8°. The frequency of phlebitis was lower in the polyurethane, in which the catheter was placed at lower angle, almost parallel to the vessel. Our results will aid in developing new catheters and in improving PIVC-securement techniques.

  6. Paravertebral block catheter breakage by electrocautery during thoracic surgery.

    Science.gov (United States)

    Saeki, Noboru; Sugimoto, Yuki; Mori, Yoko; Kato, Takahiro; Miyoshi, Hirotsugu; Nakamura, Ryuji; Koga, Tomomichi

    2017-06-01

    Advantages of thoracic paravertebral analgesia (TPA) include placement of the catheter closer to the surgical field; however, the catheter can become damaged during the operation. We experienced a case of intraoperative TPA catheter breakage that prompted us to perform an experiment to investigate possible causes. A 50-year-old male underwent a thoracoscopic lower lobectomy under general anesthesia with TPA via an intercostal approach. Following surgery, it was discovered that the catheter had become occluded, as well as cut and fused, so we reopened the incision and removed the residual catheter. From that experience, we performed an experiment to examine electrocautery-induced damage in normal (Portex™, Smith's Medical), radiopaque (Perifix SoftTip™, BBraun), and reinforced (Perifix FX™, BBraun) epidural catheters (n = 8 each). Chicken meat was penetrated by each catheter and then cut by electrocautery. In the normal group, breakage occurred in 8 and occlusion in 6 of the catheters, and in the radiopaque group breakage occurred in 8 and occlusion in 7. In contrast, breakage occurred in only 3 and occlusion in none in the reinforced group, with the 5 without breakage remaining connected only by the spring coil. Furthermore, in 7 of the reinforced catheters, electric arc-induced thermal damage was observed at the tip of the catheter. A TPA catheter for thoracic surgery should be inserted via the median approach, or it should be inserted after surgery to avoid catheter damage during surgery.

  7. Spinal canal extension of hyperalimentation catheter without neurologic sequela

    International Nuclear Information System (INIS)

    Glasier, M.; Arkansas Children's Hospital, Little Rock; Hassell, D.R.

    1989-01-01

    An attempt at placement of a left femoral vein hyperalimentation catheter resulted in entrance of the catheter into the spinal canal. Catheter location was documented by injections of nonionic contrast material into the catheter without neurologic sequellae. (orig.)

  8. Incidence of phlebitis associated with the use of peripheral IV catheter and following catheter removal

    Directory of Open Access Journals (Sweden)

    Janete de Souza Urbanetto

    Full Text Available ABSTRACT Objective: to investigate the incidence of phlebitis and its association with risk factors when using peripheral IV catheters (PIC and following their removal - (post-infusion phlebitis in hospitalized adults. Method: a cohort study of 171 patients using PIC, totaling 361 punctures. Sociodemographic variables and variables associated with the catheter were collected. Descriptive and analytical statistical analyses were performed. Results: average patient age was 56.96 and 51.5% of the sample population was male. The incidence of phlebitis was 1.25% while using PIC, and 1.38% post-infusion. The incidence of phlebitis while using PIC was associated with the length of time the catheter remained in place, whereas post-infusion phlebitis was associated with puncture in the forearm. Ceftriaxone, Clarithromycin and Oxacillin are associated with post-infusion phlebitis. Conclusions: this study made it possible to investigate the association between risk factors and phlebitis during catheter use and following its removal. The frequency of post-infusion phlebitis was larger than the incidence of phlebitis with the catheter in place, with Phlebitis Grade III and II being the most frequently found in each of these situations, respectively. Aspects related to post-infusion phlebitis can be explained, given the limited number of studies addressing this theme from this perspective.

  9. Editor's Choice - Prolonged ICU Length of Stay after AAA Repair: Analysis of Time Trends and Long-term Outcome.

    Science.gov (United States)

    Gavali, H; Mani, K; Tegler, G; Kawati, R; Covaciu, L; Wanhainen, A

    2017-08-01

    The aim of the study was to investigate the frequency and outcome of prolonged intensive care unit (ICU) length of stay (LOS) after abdominal aortic aneurysm (AAA) repair in the endovascular era. All patients operated on for AAA between 1999 and 2013 at Uppsala University hospital were identified. Data were retrieved from the Swedish Vascular registry, the Swedish Intensive Care registry, the National Population registry, and case records. Prolonged ICU LOS was defined as ≥ 48 h during the primary hospital stay. Patients surviving ≥ 48 h after AAA surgery were included in the analysis. A total of 725 patients were identified, of whom 707 (97.5%) survived ≥ 48 h; 563 (79.6%) underwent intact AAA repair and 144 (20.4%) ruptured AAA repair. A total of 548 patients (77.5%) required AAA repairs in 1999 to 7.3% in 2013 (p < .001) whereas the use of endovascular aortic repair (EVAR) increased from 6.9% in 1999 to 78.0% in 2013 (p < .001). The 30 day survival rate was 98.2% for those with < 48 h ICU stay versus 93.0% for 2-6 days versus 81.8% for ≥ 7 days (p < .001); the corresponding 90 day survival was 97.1% versus 86.1% versus 63.6% (p < .001) respectively. For patients surviving 90 days after repair, there was no difference in long-term survival between the groups. During the period of progressively increasing use of EVAR, a simultaneous significant reduction in frequency of prolonged ICU LOS occurred. Although prolonged ICU LOS was associated with a high short-term mortality, long-term outcome among those surviving the initial 90 days was less affected. Copyright © 2017 European Society for Vascular Surgery. Published by Elsevier Ltd. All rights reserved.

  10. Repositioning of malpositioned or flipped central venous catheters

    Energy Technology Data Exchange (ETDEWEB)

    Thalhammer, A.; Jacobi, V.; Balzer, J.; Vogl, T.J. [Institute for Diagnostic and Interventional Radiology, Central Radiology Clinic, J.W. Goethe University, Frankfurt am Main (Germany)

    2002-03-01

    Primary misplaced or secondary flipped implanted catheters are located mostly in the right jugular vein. We demonstrate an effective method to replace fix implanted catheters such as Ports, Grochomg or Hickman catheters. Using a femoral venous approach, replacement into the superior vena cava can easily be done with a Sidewinder 1 catheter which is hooked over the misplaced central venous approach. In all our patients the method was successful. The repositioning technique described is simple, fast and has low costs. We can keep sterile conditions and do not need to solve the catheters' fixation. (orig.)

  11. CATHETER DURATION AND THE RISK OF SEPSIS IN PREMATURE BABIES WITH UMBILICAL VEIN CATHETERS

    Directory of Open Access Journals (Sweden)

    Hartojo Hartojo

    2012-01-01

    Full Text Available Umbilical catheters are frequently required in the management of severely ill premature babies. The risk of complications may increase with duration of UVC use. Objective: To determine whether the risk of central line-associated bloodstream infections (CLA-BSIs and sepsis remained constant over the duration of umbilical vein catheters (UVCs in high-risk premature neonates. Methods:retrospective analysis. The data were collected from the medical record of high risk premature neonates who had a UVC placed in neonatal care unit of Husada Utama Hospital between April 1st 2008 to April 30th 2011 with purposive sampling. Catheter duration was observed before and after 14 days on placement. Blood and UVC culture was performed to establish the risk of CLA-BSIs and sepsis. Chi-square and logistic regression analysis were performed in the laboratorium data. Result: A total 44 high risk premature babies with UVCs were enrolled (sepsis group: n = 23 and non sepsis group: n = 21. Baseline demographics were similar between the groups. 15 babies in sepsis group have UVCs duration > 14 days, and 8 babies have UVCs 14 days show blood culture performance in 11 babies with positive evidence, UVCs culture performance is negative in 18 babies (p = 0.456. Burkholderia cepacia and Klebsiella pneumonia mostly appeared in blood culture performance. 25% of UVC culture performance shows Pseudomonas aeroginosa. Conclusions: The catheter duration have no significant difference in risk of sepsis in premature babies with Umbilical Vein Catheters.

  12. Obstruction of peritoneal dialysis catheter is associated with catheter type and independent of omentectomy: A comparative data analysis from a transplant surgical and a pediatric surgical department.

    Science.gov (United States)

    Radtke, Josephine; Schild, Raphael; Reismann, Marc; Ridwelski, Robert-Richard; Kempf, Caroline; Nashan, Bjoern; Rothe, Karin; Koch, Martina

    2018-04-01

    Peritoneal dialysis (PD) catheter occlusion is a common complication with up to 36% of catheter obstructions described in the literature. We present a comparison of complications and outcome after implantation of PD catheters in a transplant surgical and a pediatric surgical department. We retrospectively analyzed 154 PD catheters, which were implanted during 2009-2015 by transplant surgeons (TS, University Medical Center Hamburg-Eppendorf, Germany, n=85 catheters) and pediatric surgeons (PS, Charité University Medicine Berlin, Germany, n=69 catheters) in 122 children (median (range) age 3.0 (0.01-17.1) years) for acute (n=65) or chronic (n=89) renal failure. All catheters were one-cuffed or double-cuffed curled catheters, except that straight catheters were implanted into smaller children (n=19) by TS in Hamburg. Patient characteristics and operation technique did not differ between the departments. Peritonitis was the most common complication (33 catheters, 21.4%). Leakage (n=18 catheters, 11.7%) occurred more often in children weighing <10kg (p<0.001). The incidence of obstruction and dysfunction was significantly higher in catheters used in PS than catheters used in TS (30.4% vs. 11.8%, p=0.004). Omentectomy did not reduce the incidence of catheter obstruction (p=1.0). Perforation at the catheter tips was larger and appeared to be rougher in catheters used in PS than the catheters in TS. The type of catheter and presumably the type of perforation at the catheter tip may influence the incidence of peritoneal dialysis catheter obstruction. Copyright © 2017 Elsevier Inc. All rights reserved.

  13. Prolonged cardiopulmonary resuscitation and outcomes after out-of-hospital cardiac arrest

    DEFF Research Database (Denmark)

    Rajan, Shahzleen; Folke, Fredrik; Kragholm, Kristian

    2016-01-01

    AIM: It is unclear whether prolonged resuscitation can result in successful outcome following out-of-hospital cardiac arrests (OHCA). We assessed associations between duration of pre-hospital resuscitation on survival and functional outcome following OHCA in patients achieving pre-hospital return...

  14. Catheter Occlusion in Home Infusion: The Influence of Needleless Connector Design on Central Catheter Occlusion.

    Science.gov (United States)

    Williams, Ann

    Thrombotic catheter occlusion is a common complication associated with central venous catheters (CVCs). A wide variety of needleless connectors that differ greatly in design and function are available for use with CVCs; however, there are a limited number of studies comparing the catheter occlusion rate associated with differently designed needleless connectors. This retrospective observational study compared occlusion rates associated with a split-septum neutral-displacement needleless connector versus those of a solid-surface neutral-reflux needleless connector in patients undergoing home infusion therapy. The neutral-reflux needleless connector was associated with a significant reduction in occlusion rate and thrombolytic use versus the neutral-displacement needleless connector.

  15. Attitudes Towards Catheter Ablation for Atrial Fibrillation

    DEFF Research Database (Denmark)

    Vadmann, Henrik; Pedersen, Susanne S; Nielsen, Jens Cosedis

    2015-01-01

    BACKGROUND: Catheter ablation for atrial fibrillation (AF) is an important but expensive procedure that is the subject of some debate. Physicians´ attitudes towards catheter ablation may influence promotion and patient acceptance. This is the first study to examine the attitudes of Danish...... cardiologists towards catheter ablation for AF, using a nationwide survey. METHODS AND RESULTS: We developed a purpose-designed questionnaire to evaluate attitudes towards catheter ablation for AF that was sent to all Danish cardiologists (n = 401; response n = 272 (67.8%)). There was no association between...... attitudes towards ablation and the experience or age of the cardiologist with respect to patients with recurrent AF episodes with a duration of 7 days and/or need for cardioversion. The majority (69%) expected a recurrence of AF after catheter ablation in more than 30% of the cases...

  16. Catheter Angiography

    Medline Plus

    Full Text Available Toggle navigation Test/Treatment Patient Type Screening/Wellness Disease/Condition Safety En Español More Info Images/Videos About Us News Physician Resources Professions Site Index A-Z Catheter Angiography ...

  17. Technique of Peritoneal Catheter Placement under Fluoroscopic Guidance

    International Nuclear Information System (INIS)

    Abdel-Aal, A.K.; Gaddikeri, S.; Saddekni, S.

    2011-01-01

    Peritoneal catheters are mainly used for peritoneal dialysis in patients with end-stage renal disease. Other uses of this catheter include intraperitoneal chemotherapy and gene therapy for ovarian cancer and draining of uncontrolled refractory ascites in patients with liver cirrhosis. Traditionally, surgeons place most of these peritoneal catheters either by laparoscopy or open laparotomy. We detail our percutaneous approach to placing peritoneal catheters using fluoroscopic guidance. We emphasize the use of additional ultrasound guidance, including gray scale and color Doppler ultrasound, to determine the safest puncture site and to guide the initial needle puncture in order to avoid bowel perforation and injury to epigastric artery. We present our experience in placing peritoneal catheters using this technique in 95 patients with various indications. Fluoroscopic guided percutaneous placement of peritoneal catheters is a safe, minimally invasive, and effective alternative to open surgical or laparoscopic placement.

  18. Detection of electrophysiology catheters in noisy fluoroscopy images.

    Science.gov (United States)

    Franken, Erik; Rongen, Peter; van Almsick, Markus; ter Haar Romeny, Bart

    2006-01-01

    Cardiac catheter ablation is a minimally invasive medical procedure to treat patients with heart rhythm disorders. It is useful to know the positions of the catheters and electrodes during the intervention, e.g. for the automatization of cardiac mapping. Our goal is therefore to develop a robust image analysis method that can detect the catheters in X-ray fluoroscopy images. Our method uses steerable tensor voting in combination with a catheter-specific multi-step extraction algorithm. The evaluation on clinical fluoroscopy images shows that especially the extraction of the catheter tip is successful and that the use of tensor voting accounts for a large increase in performance.

  19. Epicardial phrenic nerve displacement during catheter ablation of atrial and ventricular arrhythmias: procedural experience and outcomes.

    Science.gov (United States)

    Kumar, Saurabh; Barbhaiya, Chirag R; Baldinger, Samuel H; Koplan, Bruce A; Maytin, Melanie; Epstein, Laurence M; John, Roy M; Michaud, Gregory F; Tedrow, Usha B; Stevenson, William G

    2015-08-01

    Arrhythmia origin in close proximity to the phrenic nerve (PN) can hinder successful catheter ablation. We describe our approach with epicardial PN displacement in such instances. PN displacement via percutaneous pericardial access was attempted in 13 patients (age 49±16 years, 9 females) with either atrial tachycardia (6 patients) or atrial fibrillation triggered from a superior vena cava focus (1 patient) adjacent to the right PN or epicardial ventricular tachycardia origin adjacent to the left PN (6 patients). An epicardially placed steerable sheath/4 mm-catheter combination (5 patients) or a vascular or an esophageal balloon (8 patients) was ultimately successful. Balloon placement was often difficult requiring manipulation via a steerable sheath. In 2 ventricular tachycardia cases, absence of PN capture was achieved only once the balloon was directly over the ablation catheter. In 3 atrial tachycardia patients, PN displacement was not possible with a balloon; however, a steerable sheath/catheter combination was ultimately successful. PN displacement allowed acute abolishment of all targeted arrhythmias. No PN injury occurred acutely or in follow up. Two patients developed acute complications (pleuro-pericardial fistula 1 and pericardial bleeding 1). Survival free of target arrhythmia was achieved in all atrial tachycardia patients; however, a nontargeted ventricular tachycardia recurred in 1 patient at a median of 13 months' follow up. Arrhythmias originating in close proximity to the PN can be targeted successfully with PN displacement with an epicardially placed steerable sheath/catheter combination, or balloon, but this strategy can be difficult to implement. Better tools for phrenic nerve protection are desirable. © 2015 American Heart Association, Inc.

  20. UK Renal Registry 15th annual report: Chapter 8 UK multisite peritoneal dialysis access catheter audit for first PD catheters 2011.

    Science.gov (United States)

    Briggs, Victoria; Pitcher, David; Braddon, Fiona; Fogarty, Damian; Wilkie, Martin

    2013-01-01

    The central paradigm of effective peritoneal dialysis (PD) is an appropriate standard of PD catheter function. The aim of the project was to develop an effective national PD access audit which would identify an 'appropriate standard' of PD catheter function. The UK Renal Registry collected centre specific information on various PD access outcome measures including catheter functionality and post-insertion complications. The first PD access audit covering England, Northern Ireland and Wales was conducted during April to June 2012 looking at incident dialysis patients in 2011. Forty three data collection spreadsheets were returned from a total of 65 centres describing 917 PD catheter placements. The median age of PD patients was 61 years and 61.5% were male. The proportion of patients initiated on PD in comparison to HD was lower in socially deprived areas. There was a relationship between the timing of nephrology referral and the likelihood of surgical assessment regarding PD catheter placement. Patients with diabetes did not have higher rates of PD catheter failure or of early peritonitis. A comparative PD catheter audit has the potential to provide valuable information on an important patient related outcome measure and lead to an improvement in patient experience. There was wide variation between centres of PD catheter use for late presenting patients. Overall patients were more likely to get a PD catheter if they had been known to the service for more than 1 year. The percutaneous insertion technique was associated with a higher early (less than 2 week) peritonitis rate and more catheter flow problems. Copyright © 2013 S. Karger AG, Basel.

  1. Steam-deformed Judkins-left guiding catheter with use of the GuideLiner catheter to deliver stents for anomalous right coronary artery

    Directory of Open Access Journals (Sweden)

    Toshiki Kuno

    2015-10-01

    Full Text Available Objective: Percutaneous coronary intervention for anomalous right coronary artery (RCA originating from the left coronary cusp is challenging because of our current inability to coaxially engage the guiding catheter. Methods: We report a case of an 88-year-old woman with non-ST segment elevation myocardial infarction, with an anomalous RCA origin. Using either the Judkins-Left catheter or Amplatz-Left catheter was difficult because of RCA ostium tortuosity. Thus, we used steam to deform the Judkins-Left catheter, but back-up support was insufficient to deliver the stent. Results: We used GuideLiner®, a novel pediatric catheter with rapid exchange/monorail systems, to enhance back-up support. Conclusions: We were able to successfully stent with both the deformed Judkins-Left guiding catheter and GuideLiner® for an anomalous RCA origin.

  2. Cryo-balloon catheter localization in fluoroscopic images

    Science.gov (United States)

    Kurzendorfer, Tanja; Brost, Alexander; Jakob, Carolin; Mewes, Philip W.; Bourier, Felix; Koch, Martin; Kurzidim, Klaus; Hornegger, Joachim; Strobel, Norbert

    2013-03-01

    Minimally invasive catheter ablation has become the preferred treatment option for atrial fibrillation. Although the standard ablation procedure involves ablation points set by radio-frequency catheters, cryo-balloon catheters have even been reported to be more advantageous in certain cases. As electro-anatomical mapping systems do not support cryo-balloon ablation procedures, X-ray guidance is needed. However, current methods to provide support for cryo-balloon catheters in fluoroscopically guided ablation procedures rely heavily on manual user interaction. To improve this, we propose a first method for automatic cryo-balloon catheter localization in fluoroscopic images based on a blob detection algorithm. Our method is evaluated on 24 clinical images from 17 patients. The method successfully detected the cryoballoon in 22 out of 24 images, yielding a success rate of 91.6 %. The successful localization achieved an accuracy of 1.00 mm +/- 0.44 mm. Even though our methods currently fails in 8.4 % of the images available, it still offers a significant improvement over manual methods. Furthermore, detecting a landmark point along the cryo-balloon catheter can be a very important step for additional post-processing operations.

  3. Dosimetric equivalence of nonstandard HDR brachytherapy catheter patterns

    International Nuclear Information System (INIS)

    Cunha, J. A. M.; Hsu, I-C.; Pouliot, J.

    2009-01-01

    Purpose: To determine whether alternative high dose rate prostate brachytherapy catheter patterns can result in similar or improved dose distributions while providing better access and reducing trauma. Materials and Methods: Standard prostate cancer high dose rate brachytherapy uses a regular grid of parallel needle positions to guide the catheter insertion. This geometry does not easily allow the physician to avoid piercing the critical structures near the penile bulb nor does it provide position flexibility in the case of pubic arch interference. This study used CT datasets with 3 mm slice spacing from ten previously treated patients and digitized new catheters following three hypothetical catheter patterns: conical, bi-conical, and fireworks. The conical patterns were used to accommodate a robotic delivery using a single entry point. The bi-conical and fireworks patterns were specifically designed to avoid the critical structures near the penile bulb. For each catheter distribution, a plan was optimized with the inverse planning algorithm, IPSA, and compared with the plan used for treatment. Irrelevant of catheter geometry, a plan must fulfill the RTOG-0321 dose criteria for target dose coverage (V 100 Prostate >90%) and organ-at-risk dose sparing (V 75 Bladder 75 Rectum 125 Urethra <<1 cc). Results: The three nonstandard catheter patterns used 16 nonparallel, straight divergent catheters, with entry points in the perineum. Thirty plans from ten patients with prostate sizes ranging from 26 to 89 cc were optimized. All nonstandard patterns fulfilled the RTOG criteria when the clinical plan did. In some cases, the dose distribution was improved by better sparing the organs-at-risk. Conclusion: Alternative catheter patterns can provide the physician with additional ways to treat patients previously considered unsuited for brachytherapy treatment (pubic arch interference) and facilitate robotic guidance of catheter insertion. In addition, alternative catheter

  4. Catheter ablation of epicardial ventricular tachycardia

    Directory of Open Access Journals (Sweden)

    Takumi Yamada, MD, PhD

    2014-08-01

    Full Text Available Ventricular tachycardias (VTs can usually be treated by endocardial catheter ablation. However, some VTs can arise from the epicardial surface, and their substrate can be altered only by epicardial catheter ablation. There are two approaches to epicardial catheter ablation: transvenous and transthoracic. The transvenous approach through the coronary venous system (CVS has been commonly used because it is easily accessible. However, this approach may be limited by the distribution of the CVS and insufficient radiofrequency energy delivery. Transthoracic epicardial catheter ablation has been developed to overcome these limitations of the transvenous approach. It is a useful supplemental or even preferred strategy to eliminate epicardial VTs in the electrophysiology laboratory. This technique has been applied for scar-related VTs secondary to often non-ischemic cardiomyopathy and sometimes ischemic cardiomyopathy, and idiopathic VTs as the epicardial substrates of these VTs have become increasingly recognized. When endocardial ablation and epicardial ablation through the CVS are unsuccessful, transthoracic epicardial ablation should be the next option. Intrapericardial access is usually obtained through a subxiphoidal pericardial puncture. This approach might not be possible in patients with pericardial adhesions caused by prior cardiac surgery or pericarditis. In such cases, a hybrid procedure involving surgical access with a subxiphoid pericardial window and a limited anterior or lateral thoracotomy might be a feasible and safe method of performing an epicardial catheter ablation in the electrophysiology laboratory. Potential complications associated with this technique include bleeding and collateral damage to the coronary arteries and phrenic nerve. Although the risk of these complications is low, electrophysiologists who attempt epicardial catheter ablation should know the complications associated with this technique, how to minimize their

  5. Catheter Angiography

    Medline Plus

    Full Text Available ... you are pregnant and discuss any recent illnesses, medical conditions, medications you're taking and allergies, especially ... is Catheter Angiography? Angiography is a minimally invasive medical test that helps physicians diagnose and treat medical ...

  6. Catheter Angiography

    Medline Plus

    Full Text Available ... a catheter, x-ray imaging guidance and an injection of contrast material to examine blood vessels in ... technologies and, in most cases, a contrast material injection is needed to produce pictures of blood vessels ...

  7. Catheter Angiography

    Medline Plus

    Full Text Available ... spaghetti. top of page How does the procedure work? Catheter angiography works much the same as a ... angiogram may be performed in less than an hour; however, it may last several hours. top of ...

  8. Catheter Angiography

    Medline Plus

    Full Text Available ... the American College of Radiology (ACR) and the European Society of Urogenital Radiology note that the available ... will regain their normal function within five to seven days. Rarely, the catheter punctures the artery, causing ...

  9. Catheter Angiography

    Medline Plus

    Full Text Available ... diagnosis and treatment in a single procedure. An example is finding an area of severe arterial narrowing, ... contrast material, your radiologist may advise that you take special medication for 24 hours before catheter angiography ...

  10. Catheter Angiography

    Medline Plus

    Full Text Available ... possible to combine diagnosis and treatment in a single procedure. Catheter angiography produces very detailed, clear and ... possible to combine diagnosis and treatment in a single procedure. An example is finding an area of ...

  11. Catheter Angiography

    Medline Plus

    Full Text Available ... far outweighs the risk. If you have a history of allergy to x-ray contrast material, your ... Angiography (CTA) X-ray, Interventional Radiology and Nuclear Medicine Radiation Safety Images related to Catheter Angiography Sponsored ...

  12. Catheter Angiography

    Medline Plus

    Full Text Available ... examine blood vessels in key areas of the body for abnormalities such as aneurysms and disease such ... to produce pictures of blood vessels in the body. Angiography is performed using: x-rays with catheters ...

  13. Catheter Angiography

    Medline Plus

    Full Text Available ... rare, and radiology departments are well-equipped to deal with them. There is a small risk that ... standard x-ray contrast. Catheter angiography should be done very cautiously—if at all—in patients who ...

  14. Catheter Angiography

    Medline Plus

    Full Text Available ... atherosclerosis (plaque). The use of a catheter makes it possible to combine diagnosis and treatment in a ... the aorta in the chest or abdomen or its major branches. show the extent and severity of ...

  15. Catheter Angiography

    Medline Plus

    Full Text Available ... 20 minutes (or by using a special closure device). When the examination is complete, you may be ... contrast material, your radiologist may advise that you take special medication for 24 hours before catheter angiography ...

  16. Catheter Angiography

    Medline Plus

    Full Text Available ... rays ). top of page What are some common uses of the procedure? Catheter angiography is used to ... community, you can search the ACR-accredited facilities database . This website does not provide cost information. The ...

  17. Catheter Angiography

    Medline Plus

    Full Text Available ... spaghetti. top of page How does the procedure work? Catheter angiography works much the same as a ... and x-rays. Manufacturers of intravenous contrast indicate mothers should not breastfeed their babies for 24-48 ...

  18. Catheter Angiography

    Medline Plus

    Full Text Available ... spaghetti. top of page How does the procedure work? Catheter angiography works much the same as a ... possible to combine diagnosis and treatment in a single procedure. An example is finding an area of ...

  19. Catheter Angiography

    Medline Plus

    Full Text Available ... Once the catheter is guided to the area being examined, a contrast material is injected through the ... You should inform your physician of any medications being taken and if there are any allergies, especially ...

  20. Percutaneous transfemoral repositioning of malpositioned central venous catheters.

    Science.gov (United States)

    Hartnell, G G; Roizental, M

    1995-04-01

    Central venous catheters inserted by blind surgical placement may not advance into a satisfactory position and may require repositioning. Malpositioning via surgical insertion is common in patients in whom central venous catheters have previously been placed, as these patients are more likely to have central venous thrombosis and distortion of central venous anatomy. This is less of a problem when catheter placement is guided by imaging; however, even when insertion is satisfactory, central venous catheters may become displaced spontaneously after insertion (Fig. 1). Repositioning can be effected by direct manipulation using guidewires or tip-deflecting wires [1, 2], by manipulation via a transfemoral venous approach [3-5], and by injection of contrast material or saline [6]. Limitations of the direct approach include (1) the number and type of maneuvers that can be performed to effect repositioning when anatomy is distorted, (2) difficulty in accessing the catheter, and (3) the risk of introducing infection. Moreover, these patients are often immunosuppressed, and there is a risk of introducing infection by exposing and directly manipulating the venous catheter. Vigorous injection of contrast material or saline may be unsuccessful for the same reasons: It seldom exerts sufficient force to reposition large-caliber central venous catheters and may cause vessel damage or rupture if injection is made into a small or thrombosed vessel. We illustrate several alternative methods for catheter repositioning via a transfemoral venous approach.

  1. A prospective interventional study to examine the effect of a silver alloy and hydrogel-coated catheter on the incidence of catheter-associated urinary tract infection.

    Science.gov (United States)

    Chung, P Hy; Wong, C Wy; Lai, C Kc; Siu, H K; Tsang, D Nc; Yeung, K Y; Ip, D Km; Tam, P Kh

    2017-06-01

    Catheter-associated urinary tract infection is a major hospital-acquired infection. This study aimed to analyse the effect of a silver alloy and hydrogel-coated catheter on the occurrence of catheter-associated urinary tract infection. This was a 1-year prospective study conducted at a single centre in Hong Kong. Adult patients with an indwelling urinary catheter for longer than 24 hours were recruited. The incidence of catheter-associated urinary tract infection in patients with a conventional latex Foley catheter without hydrogel was compared with that in patients with a silver alloy and hydrogel-coated catheter. The most recent definition of urinary tract infection was based on the latest surveillance definition of the National Healthcare Safety Network managed by Centers for Disease Control and Prevention. A total of 306 patients were recruited with a similar ratio between males and females. The mean (standard deviation) age was 81.1 (10.5) years. The total numbers of catheter-days were 4352 and 7474 in the silver-coated and conventional groups, respectively. The incidences of catheter-associated urinary tract infection per 1000 catheter-days were 6.4 and 9.4, respectively (P=0.095). There was a 31% reduction in the incidence of catheter-associated urinary tract infection per 1000 catheter-days in the silver-coated group. Escherichia coli was the most commonly involved pathogen (36.7%) of all cases. Subgroup analysis revealed that the protective effect of silver-coated catheter was more pronounced in long-term users as well as female patients with a respective 48% (P=0.027) and 42% (P=0.108) reduction in incidence of catheter-associated urinary tract infection. The mean catheterisation time per person was the longest in patients using a silver-coated catheter (17.0 days) compared with those using a conventional (10.8 days) or both types of catheter (13.6 days) [P=0.01]. Silver alloy and hydrogel-coated catheters appear to be effective in preventing catheter

  2. Removal of non-deflatable retained foley catheter in the bladder by percutaneous puncture of catheter balloon

    International Nuclear Information System (INIS)

    Yoo, Jae Duk; Kim, Jae Kyu; Park, Jin Gyun; Chung, Hyon De

    1988-01-01

    Nondeflatable Foley catheter in the bladder is an uncommon event. We recently experienced a patient in whom the urologist were unable to remove a Foley catheter with cystoscope due to public bone fractures. The procedure, which was successfully carried out, consists of puncturing the ballon under fluoroscope.

  3. Iatrogenic Bowel Injury at Exchange of Supra-Pubic Catheter

    LENUS (Irish Health Repository)

    Foran, AT

    2018-04-01

    Suprapubic catheter insertion and exchange is a common urological procedure, but it is not without risks and complications. While bowel perforation is a recognised complication at suprapubic catheter insertion, it is not commonly reported at suprapubic catheter exchange. We report our experience of recognition, diagnosis and subsequent successful management of the most important complication related to suprapubic catheters.

  4. Analog experiment of transarterial catheter hyperthermic infusion in vitro

    International Nuclear Information System (INIS)

    Fan Shufeng Li Zheng; Gu Weizhong; Ru Fuming

    2006-01-01

    Objective: To investigate the factors related to the heating effect by transarterial catheter hyperthermic infusion with the evaluation of the feasibility in controlling the tumor temperature. Methods: Infusing 55-68 degree C liquid at the speed of 10-40 ml/min through 6F, 5F or 3F catheter with different length respectively under the similar clinical condition. The liquid temperature at the terminal exit of the catheter was measured with a digital thermometer. The factors related to the liquid temperature at the exit of the catheter were analyzed by multiple regression analysis. Results: The infusion temperature , rate and the catheter length were the main related factors to the liquid temperature at the exit of the catheter as the condition similar in clinical use. When 60-65 degree C liquid was infused at the rate of 20-40 ml/min through 5F catheter with length of 80 cm, the mean and 95% confident interval of the liquid temperature at the catheter exit were (47.55±0.44) degree C and 44.61-48.49 degree C respectively. Conclusions: The liquid temperature at the exit of infusion catheter can be regulated and controlled through adjusting the liquid perfusion temperature and speed. (authors)

  5. The bowed catheter sign: a risk for pericardial tamponade

    Energy Technology Data Exchange (ETDEWEB)

    Towbin, Richard [Phoenix Children' s Hospital, Department of Radiology, Phoenix, AZ (United States)

    2008-03-15

    The use of a central venous catheter (CVC) has become commonplace in the care of children with a wide variety of medical and surgical problems. Complications resulting from the insertion of these catheters are well recognized and can be life-threatening. When a temporary CVC or other catheter is inserted into the central venous system it is secured to the skin with a combination of sutures and sterile dressing. This fixes the catheter in place and does not allow it to retract, thereby putting pressure on the right atrial wall via the catheter tip if it is too long. The probability of wall penetration is increased if a catheter or device is tapered at the point of contact. The purpose of this case report is to present the bowed catheter sign and to review the anatomy of the cavotricuspid isthmus, a possible predisposing factor to cardiac perforation and tamponade. (orig.)

  6. The bowed catheter sign: a risk for pericardial tamponade

    International Nuclear Information System (INIS)

    Towbin, Richard

    2008-01-01

    The use of a central venous catheter (CVC) has become commonplace in the care of children with a wide variety of medical and surgical problems. Complications resulting from the insertion of these catheters are well recognized and can be life-threatening. When a temporary CVC or other catheter is inserted into the central venous system it is secured to the skin with a combination of sutures and sterile dressing. This fixes the catheter in place and does not allow it to retract, thereby putting pressure on the right atrial wall via the catheter tip if it is too long. The probability of wall penetration is increased if a catheter or device is tapered at the point of contact. The purpose of this case report is to present the bowed catheter sign and to review the anatomy of the cavotricuspid isthmus, a possible predisposing factor to cardiac perforation and tamponade. (orig.)

  7. Steam-deformed Judkins-left guiding catheter with use of the GuideLiner(®) catheter to deliver stents for anomalous right coronary artery.

    Science.gov (United States)

    Kuno, Toshiki; Fujisawa, Taishi; Yamazaki, Hiroyuki; Motoda, Hiroyuki; Kodaira, Masaki; Numasawa, Yohei

    2015-01-01

    Percutaneous coronary intervention for anomalous right coronary artery (RCA) originating from the left coronary cusp is challenging because of our current inability to coaxially engage the guiding catheter. We report a case of an 88-year-old woman with non-ST segment elevation myocardial infarction, with an anomalous RCA origin. Using either the Judkins-Left catheter or Amplatz-Left catheter was difficult because of RCA ostium tortuosity. Thus, we used steam to deform the Judkins-Left catheter, but back-up support was insufficient to deliver the stent. We used GuideLiner®, a novel pediatric catheter with rapid exchange/monorail systems, to enhance back-up support. We were able to successfully stent with both the deformed Judkins-Left guiding catheter and GuideLiner® for an anomalous RCA origin.

  8. Catheter Associated Urinary Tract Infection Prevention bundle

    Directory of Open Access Journals (Sweden)

    O. Zarkotou

    2017-01-01

    Full Text Available Catheter-associated urinary tract infections (CAUTI are among the most common healthcare-associated infections, and potentially lead to significant morbidity and mortality. Multifaceted infection control strategies implemented as bundles can prevent nosocomial infections associated with invasive devices such as CAUTIs. The components of the CAUTI bundle proposed herein, include appropriate indications for catheterization and recommendations for the procedures of catheter insertion and catheter maintenance and care. Avoiding unnecessary urinary catheter use is the most effective measure for their prevention. To minimize the risk of CAUTI, urinary catheters should be placed only when a clinical valid indication is documented and they should be removed as soon as possible; alternatives to catheterization should also be considered. Aseptic insertion technique, maintenance of closed drainage system and strict adherence to hand hygiene are essential for preventing CAUTI. The successful implementation of the bundle requires education and training for all healthcare professionals and evaluation of surveillance data.

  9. Human umbilical cord mesenchymal stromal cells suppress MHC class II expression on rat vascular endothelium and prolong survival time of cardiac allograft

    Science.gov (United States)

    Qiu, Ying; Yun, Mark M; Han, Xia; Zhao, Ruidong; Zhou, Erxia; Yun, Sheng

    2014-01-01

    Background: Human umbilical cord mesenchymal stromal cells (UC-MSCs) have low immunogenicity and immune regulation. To investigate immunomodulatory effects of human UC-MSCs on MHC class II expression and allograft, we transplanted heart of transgenic rats with MHC class II expression on vascular endothelium. Methods: UC-MSCs were obtained from human umbilical cords and confirmed with flow cytometry analysis. Transgenic rat line was established using the construct of human MHC class II transactivator gene (CIITA) under mouse ICAM-2 promoter control. The induced MHC class II expression on transgenic rat vascular endothelial cells (VECs) was assessed with immunohistological staining. And the survival time of cardiac allograft was compared between the recipients with and without UC-MSC transfusion. Results: Flow cytometry confirmed that the human UC-MSCs were positive for CD29, CD44, CD73, CD90, CD105, CD271, and negative for CD34 and HLA-DR. Repeated infusion of human UC-MSCs reduced MHC class II expression on vascular endothelia of transplanted hearts, and increased survival time of allograft. The UC-MSCs increased regulatory cytokines IL10, transforming growth factor (TGF)-β1 and suppressed proinflammatory cytokines IL2 and IFN-γ in vivo. The UC-MSC culture supernatant had similar effects on cytokine expression, and decreased lymphocyte proliferation in vitro. Conclusions: Repeated transfusion of the human UC-MSCs reduced MHC class II expression on vascular endothelia and prolonged the survival time of rat cardiac allograft. PMID:25126177

  10. Central venous catheter insertion problem solving using intravenous catheter: technical communication

    Directory of Open Access Journals (Sweden)

    Alemohammad M

    2013-02-01

    Full Text Available Insertion of central venous catheter is an accepted method for hemodynamic monitor-ring, drug and fluid administration, intravenous access, hemodialysis and applying cardiac pace-maker in hospitalized patients. This procedure can be associated with severe complications. The aim of this article is to provide a practical approach to prevent catheter malposition in states that the guide wire will not pass freely.During central venous insertion in internal jugular vein using modified seldinger technique, when after venous insertion, the passage of the guide wire shows difficulties and don’t pass freely, insertion of an intravenous cannula over the wire and re-insertion of the wire can help to prevent malposition of the wire and the catheter. Use of an intravenous cannula over the guide, in situations that the guide wire cannot pass freely among the needle inserted in internal jugular vein, and re-insertion of the guide can probably prevent or reduce the tissue or vascular trauma and the associated complica-tions. This simple maneuver can be helpful in difficult cases especially in cardiac surgery patients who receive high dose heparin and it is necessary to avoid traumatize-tion of carotid artery.

  11. A biodegradable, sustained-released, prednisolone acetate microfilm drug delivery system effectively prolongs corneal allograft survival in the rat keratoplasty model.

    Directory of Open Access Journals (Sweden)

    Yu-Chi Liu

    Full Text Available Frequent and long-term use of topical corticosteroids after corneal transplantation is necessary to prevent graft rejection. However, it relies heavily on patient compliance, and sustained therapeutic drug levels are often not achieved with administration of topical eye drops. A biodegradable drug delivery system with a controlled and sustained drug release may circumvent these limitations. In this study, we investigated the efficacy of a prednisolone acetate (PA-loaded poly (d,l-lactide-co-ε-caprolactone (PLC microfilm drug delivery system on promoting the survival of allogeneic grafts after penetrating keratoplasty (PK using a rat model. The drug release profiles of the microfilms were characterized (group 1. Subsequently, forty-eight PK were performed in four experimental groups: syngeneic control grafts (group 2, allogeneic control grafts (group 3, allogeneic grafts with subconjunctivally-implanted PA microfilm (group 4, and allogeneic grafts with PA eye drops (group 5; n = 12 in each. PA-loaded microfilm achieved a sustained and steady release at a rate of 0.006-0.009 mg/day, with a consistent aqueous drug concentration of 207-209 ng/ml. The mean survival days was >28 days in group 2, 9.9±0.8 days in group 3, 26.8±2.7 days in group 4, and 26.4±3.4 days in group 5 (P = 0.023 and P = 0.027 compared with group 3. Statistically significant decrease in CD4+, CD163+, CD 25+, and CD54+ cell infiltration was observed in group 4 and group 5 compared with group 3 (P<0.001. There was no significant difference in the mean survival and immunohistochemical analysis between group 4 and group 5. These results showed that sustained PA-loaded microfilm effectively prolongs corneal allograft survival. It is as effective as conventional PA eye drops, providing a promising clinically applicable alternative for patients undergoing corneal transplantation.

  12. Catheter Angiography

    Medline Plus

    Full Text Available ... story about radiology? Share your patient story here Images × Image Gallery Interventional radiologist performing an angiography exam View ... ray, Interventional Radiology and Nuclear Medicine Radiation Safety Images related to Catheter Angiography Sponsored by Please note ...

  13. Adjuvant Radiation Therapy Treatment Time Impacts Overall Survival in Gastric Cancer

    International Nuclear Information System (INIS)

    McMillan, Matthew T.; Ojerholm, Eric; Roses, Robert E.; Plastaras, John P.; Metz, James M.; Mamtani, Ronac; Karakousis, Giorgos C.; Fraker, Douglas L.; Drebin, Jeffrey A.; Stripp, Diana; Ben-Josef, Edgar; Datta, Jashodeep

    2015-01-01

    Purpose: Prolonged radiation therapy treatment time (RTT) is associated with worse survival in several tumor types. This study investigated whether delays during adjuvant radiation therapy impact overall survival (OS) in gastric cancer. Methods and Materials: The National Cancer Data Base was queried for patients with resected gastric cancer who received adjuvant radiation therapy with National Comprehensive Cancer Network–recommended doses (45 or 50.4 Gy) between 1998 and 2006. RTT was classified as standard (45 Gy: 33-36 days, 50.4 Gy: 38-41 days) or prolonged (45 Gy: >36 days, 50.4 Gy: >41 days). Cox proportional hazards models evaluated the association between the following factors and OS: RTT, interval from surgery to radiation therapy initiation, interval from surgery to radiation therapy completion, radiation therapy dose, demographic/pathologic and operative factors, and other elements of adjuvant multimodality therapy. Results: Of 1591 patients, RTT was delayed in 732 (46%). Factors associated with prolonged RTT were non-private health insurance (OR 1.3, P=.005) and treatment at non-academic facilities (OR 1.2, P=.045). Median OS and 5-year actuarial survival were significantly worse in patients with prolonged RTT compared with standard RTT (36 vs 51 months, P=.001; 39 vs 47%, P=.005); OS worsened with each cumulative week of delay (P<.0004). On multivariable analysis, prolonged RTT was associated with inferior OS (hazard ratio 1.2, P=.002); the intervals from surgery to radiation therapy initiation or completion were not. Prolonged RTT was particularly detrimental in patients with node positivity, inadequate nodal staging (<15 nodes examined), and those undergoing a cycle of chemotherapy before chemoradiation therapy. Conclusions: Delays during adjuvant radiation therapy appear to negatively impact survival in gastric cancer. Efforts to minimize cumulative interruptions to <7 days should be considered

  14. Adjuvant Radiation Therapy Treatment Time Impacts Overall Survival in Gastric Cancer

    Energy Technology Data Exchange (ETDEWEB)

    McMillan, Matthew T. [Department of Radiation Oncology, University of Pennsylvania Perelman School of Medicine, Philadelphia, Pennsylvania (United States); Department of Surgery, University of Pennsylvania Perelman School of Medicine, Philadelphia, Pennsylvania (United States); Ojerholm, Eric [Department of Radiation Oncology, University of Pennsylvania Perelman School of Medicine, Philadelphia, Pennsylvania (United States); Roses, Robert E., E-mail: Robert.Roses@uphs.upenn.edu [Department of Surgery, University of Pennsylvania Perelman School of Medicine, Philadelphia, Pennsylvania (United States); Plastaras, John P.; Metz, James M. [Department of Radiation Oncology, University of Pennsylvania Perelman School of Medicine, Philadelphia, Pennsylvania (United States); Mamtani, Ronac [Department of Hematology/Oncology, University of Pennsylvania Perelman School of Medicine, Philadelphia, Pennsylvania (United States); Karakousis, Giorgos C.; Fraker, Douglas L.; Drebin, Jeffrey A. [Department of Surgery, University of Pennsylvania Perelman School of Medicine, Philadelphia, Pennsylvania (United States); Stripp, Diana; Ben-Josef, Edgar [Department of Radiation Oncology, University of Pennsylvania Perelman School of Medicine, Philadelphia, Pennsylvania (United States); Datta, Jashodeep [Department of Surgery, University of Pennsylvania Perelman School of Medicine, Philadelphia, Pennsylvania (United States)

    2015-10-01

    Purpose: Prolonged radiation therapy treatment time (RTT) is associated with worse survival in several tumor types. This study investigated whether delays during adjuvant radiation therapy impact overall survival (OS) in gastric cancer. Methods and Materials: The National Cancer Data Base was queried for patients with resected gastric cancer who received adjuvant radiation therapy with National Comprehensive Cancer Network–recommended doses (45 or 50.4 Gy) between 1998 and 2006. RTT was classified as standard (45 Gy: 33-36 days, 50.4 Gy: 38-41 days) or prolonged (45 Gy: >36 days, 50.4 Gy: >41 days). Cox proportional hazards models evaluated the association between the following factors and OS: RTT, interval from surgery to radiation therapy initiation, interval from surgery to radiation therapy completion, radiation therapy dose, demographic/pathologic and operative factors, and other elements of adjuvant multimodality therapy. Results: Of 1591 patients, RTT was delayed in 732 (46%). Factors associated with prolonged RTT were non-private health insurance (OR 1.3, P=.005) and treatment at non-academic facilities (OR 1.2, P=.045). Median OS and 5-year actuarial survival were significantly worse in patients with prolonged RTT compared with standard RTT (36 vs 51 months, P=.001; 39 vs 47%, P=.005); OS worsened with each cumulative week of delay (P<.0004). On multivariable analysis, prolonged RTT was associated with inferior OS (hazard ratio 1.2, P=.002); the intervals from surgery to radiation therapy initiation or completion were not. Prolonged RTT was particularly detrimental in patients with node positivity, inadequate nodal staging (<15 nodes examined), and those undergoing a cycle of chemotherapy before chemoradiation therapy. Conclusions: Delays during adjuvant radiation therapy appear to negatively impact survival in gastric cancer. Efforts to minimize cumulative interruptions to <7 days should be considered.

  15. Locally advanced pancreatic cancer: association between prolonged preoperative treatment and lymph-node negativity and overall survival.

    Science.gov (United States)

    Kadera, Brian E; Sunjaya, Dharma B; Isacoff, William H; Li, Luyi; Hines, O Joe; Tomlinson, James S; Dawson, David W; Rochefort, Matthew M; Donald, Graham W; Clerkin, Barbara M; Reber, Howard A; Donahue, Timothy R

    2014-02-01

    Treatment of patients with locally advanced/borderline resectable (LA/BR) pancreatic ductal adenocarcinoma (PDAC) is not standardized. To (1) perform a detailed survival analysis of our institution's experience with patients with LA/BR PDAC who were downstaged and underwent surgical resection and (2) identify prognostic biomarkers that may help to guide a decision for the use of adjuvant therapy in this patient subgroup. Retrospective observational study of 49 consecutive patients from a single institution during 1992-2011 with American Joint Committee on Cancer stage III LA/BR PDAC who were initially unresectable, as determined by staging computed tomography and/or surgical exploration, and who were treated and then surgically resected. Clinicopathologic variables and prognostic biomarkers SMAD4, S100A2, and microRNA-21 were correlated with survival by univariate and multivariate Cox proportional hazard modeling. All 49 patients were deemed initially unresectable owing to vascular involvement. After completing preoperative chemotherapy for a median of 7.1 months (range, 5.4-9.6 months), most (75.5%) underwent a pylorus-preserving Whipple operation; 3 patients (6.1%) had a vascular resection. Strikingly, 37 of 49 patients were lymph-node (LN) negative (75.5%) and 42 (85.7%) had negative margins; 45.8% of evaluable patients achieved a complete histopathologic (HP) response. The median overall survival (OS) was 40.1 months (range, 22.7-65.9 months). A univariate analysis of HP prognostic biomarkers revealed that perineural invasion (hazard ratio, 5.5; P=.007) and HP treatment response (hazard ratio, 9.0; P=.009) were most significant. Lymph-node involvement, as a marker of systemic disease, was also significant on univariate analysis (P=.05). Patients with no LN involvement had longer OS (44.4 vs 23.2 months, P=.04) than LN-positive patients. The candidate prognostic biomarkers, SMAD4 protein loss (P=.01) in tumor cells and microRNA-21 expression in the stroma (P=.05

  16. Outbreak of Fusarium oxysporum infections in children with cancer: an experience with 7 episodes of catheter-related fungemia.

    Science.gov (United States)

    Carlesse, Fabianne; Amaral, Anna-Paula C; Gonçalves, Sarah S; Xafranski, Hemilio; Lee, Maria-Lucia M; Zecchin, Victor; Petrilli, Antonio S; Al-Hatmi, Abdullah M; Hagen, Ferry; Meis, Jacques F; Colombo, Arnaldo L

    2017-01-01

    Fusarium species are widely spread in nature as plant pathogens but are also able to cause opportunistic fungal infections in humans. We report a cluster of Fusarium oxysporum bloodstream infections in a single pediatric cancer center. All clinical and epidemiological data related to an outbreak involving seven cases of fungemia by Fusarium oxysporum during October 2013 and February 2014 were analysed. All cultured isolates ( n  = 14) were identified to species level by sequencing of the TEF1 and RPB2 genes. Genotyping of the outbreak isolates was performed by amplified fragment length polymorphism fingerprinting. In a 5-month period 7 febrile pediatric cancer patients were diagnosed with catheter-related Fusarium oxysporum bloodstream infections. In a time span of 11 years, only 6 other infections due to Fusarium were documented and all were caused by a different species, Fusarium solani . None of the pediatric cancer patients had neutropenia at the time of diagnosis and all became febrile within two days after catheter manipulation in a specially designed room. Extensive environmental sampling in this room and the hospital did not gave a clue to the source. The outbreak was terminated after implementation of a multidisciplinary central line insertion care bundle. All Fusarium strains from blood and catheter tips were genetically related by amplified fragment length polymorphism fingerprinting. All patients survived the infection after prompt catheter removal and antifungal therapy. A cluster with, genotypical identical, Fusarium oxysporum strains infecting 7 children with cancer, was most probably catheter-related. The environmental source was not discovered but strict infection control measures and catheter care terminated the outbreak.

  17. Outbreak of Fusarium oxysporum infections in children with cancer: an experience with 7 episodes of catheter-related fungemia

    Directory of Open Access Journals (Sweden)

    Fabianne Carlesse

    2017-09-01

    Full Text Available Abstract Background Fusarium species are widely spread in nature as plant pathogens but are also able to cause opportunistic fungal infections in humans. We report a cluster of Fusarium oxysporum bloodstream infections in a single pediatric cancer center. Methods All clinical and epidemiological data related to an outbreak involving seven cases of fungemia by Fusarium oxysporum during October 2013 and February 2014 were analysed. All cultured isolates (n = 14 were identified to species level by sequencing of the TEF1 and RPB2 genes. Genotyping of the outbreak isolates was performed by amplified fragment length polymorphism fingerprinting. Results In a 5-month period 7 febrile pediatric cancer patients were diagnosed with catheter-related Fusarium oxysporum bloodstream infections. In a time span of 11 years, only 6 other infections due to Fusarium were documented and all were caused by a different species, Fusarium solani. None of the pediatric cancer patients had neutropenia at the time of diagnosis and all became febrile within two days after catheter manipulation in a specially designed room. Extensive environmental sampling in this room and the hospital did not gave a clue to the source. The outbreak was terminated after implementation of a multidisciplinary central line insertion care bundle. All Fusarium strains from blood and catheter tips were genetically related by amplified fragment length polymorphism fingerprinting. All patients survived the infection after prompt catheter removal and antifungal therapy. Conclusion A cluster with, genotypical identical, Fusarium oxysporum strains infecting 7 children with cancer, was most probably catheter-related. The environmental source was not discovered but strict infection control measures and catheter care terminated the outbreak.

  18. An epidural catheter removal after recent percutaneous coronary intervention and coronary artery stenting: Epidural catheter and antiaggregation therapy

    Directory of Open Access Journals (Sweden)

    Joksić Nikola

    2016-01-01

    Full Text Available Introduction: Anticoagulation and antiplatelet therapy in the presence of the epidural catheter is still controversial. It is well known that dual antiplatelet therapy is indicated for 12 months after the placement of drug-eluting stents (DES. Removal of an epidural catheter during that period is related to an increased risk of stent occlusion in case of discontinuation of platelet function inhibitors or, on the other hand, increased risk of epidural hematoma associated with neurological deficit if suppressed platelet function is still present. Case Report: Here we present a case of a 63-year-old man who was admitted to Institute for Cardiovascular Diseases Dedinje for elective aortic surgery. Before the induction, an epidural catheter was inserted at the Th10-Th11 epidural space. Uneventful surgery was performed under the combined epidural and general anesthesia. On the 2nd postoperative day, the patient sustained a ST depression myocardial infarction treated with percutaneous coronary intervention with DES placement, while epidural catheter was still in place. Dual antiplatelet therapy with 600mg of clopidogrel, 100 mg of acetilsalicylic acid (ASA and low molecular weight heparin (LMWH were started during the procedure. The next day, clopidogrel (75 mg and ASA (100 mg were continued as well as LMWH. The decision to remove the epidural catheter was made on the 9th postoperative day, after platelet aggregation assays were performed. Six hours after catheter removal the patient again received clopidogrel, ASA and LMWH. There were no signs of epidural hematoma. Conclusion: This case shows that point-of-care testing with platelet aggregation assays may be useful in increasing the margin of safety for epidural catheter removal during dual antiplatelet therapy.

  19. Urethral catheters: can we reduce use?

    NARCIS (Netherlands)

    Broek, P.J. van den; Wille, J.C.; Benthem, B.H.B. van; Perenboom, R.J.M.; Akker-van Marle, M.E. van den; Nielen, A.M.A.

    2011-01-01

    Indwelling urinary catheters are the main cause of healthcare-associated urinary tract infections. It can be expected that reduction of the use of urinary catheters will lead to decreased numbers of urinary tract infection. The efficacy of an intervention programme to improve adherence to

  20. Bacterial Biofilms and Catheters: A Key to Understanding Bacterial Strategies in Catheter-Associated Urinary Tract Infection

    Directory of Open Access Journals (Sweden)

    J Curtis Nickel

    1992-01-01

    Full Text Available Despite major technological improvements in catheter drainage systems, the indwelling Foley catheter remains the most common cause of nosocomial infection in medical practice. By approaching this common complicated urinary tract infection from the perspective of the biofilm strategy bacteria appear to use to overcome obstacles to produce bacteriuria, one appreciates a new understanding of these infections. An adherent biofilm of bacteria in their secretory products ascends the luminal and external surface of the catheter and drainage system from a contaminated drainage spigot or urethral meatus into the bladder. If the intraluminal route of bacterial ascent is delayed by strict sterile closed drainage or addition of internal modifications to the system, the extraluminal or urethral route assumes greater importance in the development of bacteriuria, but takes significantly longer. Bacterial growth within these thick coherent biofilms confers a large measure of relative resistance to antibiotics even though the individual bacterium remains sensitive, thus accounting for the failure of antibiotic therapy. With disruption of the protective mucous layer of the bladder by mechanical irritation, the bacteria colonizing the catheter can adhere to the bladder’s mucosal surface and cause infection. An appreciation of the role of bacterial biofilms in these infections should suggest future directions for research that may ultimately reduce the risk of catheter-associated infection.

  1. Spontaneous rotation of the monorail-type guide extension support catheter during advancement of a curved guiding catheter: the potential hazard of twisting with the coronary guidewire.

    Science.gov (United States)

    Hashimoto, Sho; Takahashi, Akihiko; Yamada, Takeshi; Mizuguchi, Yukio; Taniguchi, Norimasa; Hata, Tetsuya; Nakajima, Shunsuke

    2017-11-20

    The extension support guiding catheter has been used to perform complex percutaneous coronary intervention to increase back-up support for the guiding catheter or to ensure deep intubation for device delivery. However, because of its monorail design, advancement of the stent into the distal extension tubing segment is sometimes problematic. Although this problem is considered due to simple collision of the stent, operators have observed tangling between a monorail extension catheter and coronary guidewire in some patients. To examine movement of the collar of the extension guide catheter during advancement of the guiding catheter, we set up an in vitro model in which the guiding catheter had two curves. Rotation of the extension guide catheter was examined by both fluoroscopic imaging and movement of the hub of the proximal end of the catheter. During advancement in the first curve, the collar moved toward the outer side of the curve of the guiding catheter as the operator pushed the shaft of the extension guiding catheter, which overrode the guidewire. After crossing the first curve, the collar moved again to the outer side of the second curve (the inner side of the first curve) of the mother catheter, and then, another clockwise rotation was observed in the proximal hub. Consequently, the collar and tubing portion of the extension guide catheter rotated 360° around the coronary guidewire, and the monorail extension catheter and guidewire became tangled. There is a potential risk of unintentional twisting with the guidewire during advancement into the curved guiding catheter because of its monorail design.

  2. Catheter placement for lysis of spontaneous intracerebral hematomas: does a catheter position in the core of the hematoma allow more effective and faster hematoma lysis?

    Science.gov (United States)

    Malinova, Vesna; Schlegel, Anna; Rohde, Veit; Mielke, Dorothee

    2017-07-01

    For the fibrinolytic therapy of intracerebral hematomas (ICH) using recombinant tissue plasminogen activator (rtPA), a catheter position in the core of the hematoma along the largest clot diameter was assumed to be optimal for an effective clot lysis. However, it never had been proven that core position indeed enhances clot lysis if compared with less optimal catheter positions. In this study, the impact of the catheter position on the effectiveness and on the time course of clot lysis was evaluated. We analyzed the catheter position using a relative error calculating the distance perpendicular to the catheter's center in relation to hematoma's diameter and evaluated the relative hematoma volume reduction (RVR). The correlation of the RVR with the catheter position was evaluated. Additionally, we tried to identify patterns of clot lysis with different catheter positions. The patient's outcome at discharge was evaluated using the Glasgow outcome score. A total of 105 patients were included in the study. The mean hematoma volume was 56 ml. The overall RVR was 62.7 %. In 69 patients, a catheter position in the core of the clot was achieved. We found no significant correlation between catheter position and hematoma RVR (linear regression, p = 0.14). Core catheter position leads to more symmetrical hematoma RVR. Faster clot lysis happens in the vicinity of the catheter openings. We found no significant difference in the patient's outcome dependent on the catheter position (linear regression, p = 0.90). The catheter position in the core of the hematoma along its largest diameter does not significantly influence the effectiveness of clot lysis after rtPA application.

  3. Types of urethral catheter for reducing symptomatic urinary tract infections in hospitalised adults requiring short-term catheterisation: multicentre randomised controlled trial and economic evaluation of antimicrobial- and antiseptic-impregnated urethral catheters (the CATHETER trial).

    Science.gov (United States)

    Pickard, R; Lam, T; Maclennan, G; Starr, K; Kilonzo, M; McPherson, G; Gillies, K; McDonald, A; Walton, K; Buckley, B; Glazener, C; Boachie, C; Burr, J; Norrie, J; Vale, L; Grant, A; N'dow, J

    2012-11-01

    Catheter-associated urinary tract infection (CAUTI) is a major preventable cause of harm for patients in hospital and incurs significant costs for health-care providers such as the UK NHS. Many preventative strategies and measures have been introduced to minimise CAUTI risk, including the use of antimicrobial catheters. However, there is considerable uncertainty regarding their usefulness in terms of reducing symptomatic CAUTI, and whether or not they are cost-effective. Do antimicrobial catheters reduce the rate of symptomatic urinary tract infection (UTI) during short-term hospital use and is their use cost-effective for the UK NHS? A pragmatic multicentre UK randomised controlled trial comparing three catheters as they would be used in the UK NHS: antimicrobial-impregnated (nitrofurazone) and antiseptic-coated (silver alloy) catheters with the standard polytetrafluoroethylene (PTFE)-coated catheters. Economic evaluation used a decision model populated with data from the trial. Sensitivity analysis was used to explore uncertainty. Relevant clinical departments in 24 NHS hospitals throughout the UK. Adults requiring temporary urethral catheterisation for a period of between 1 and 14 days as part of their care, predominantly as a result of elective surgery. Eligible participants were randomised 1 : 1 : 1 to one of three types of urethral catheter in order to make the following pragmatic comparisons: nitrofurazone-impregnated silicone catheter compared with standard PTFE-coated latex catheter; and silver alloy-coated hydrogel latex catheter compared with standard PTFE-coated latex catheter. The primary outcome for clinical effectiveness was the incidence of UTI at any time up to 6 weeks post randomisation. This was defined as any symptom reported during catheterisation, up to 3 days or 1 or 2 weeks post catheter removal or 6 weeks post randomisation combined with a prescription of antibiotics, at any of these times, for presumed symptomatic UTI. The primary economic

  4. Catheter Angiography

    Medline Plus

    Full Text Available ... key areas of the body for abnormalities such as aneurysms and disease such as atherosclerosis (plaque). The use of a catheter makes ... including the: brain neck heart chest abdomen (such as the kidneys and liver) pelvis legs and feet ...

  5. Catheter Angiography

    Medline Plus

    Full Text Available Toggle navigation Test/Treatment Patient Type Screening/Wellness Disease/Condition Safety En Español More Info Images/Videos About Us News Physician ... Catheter Angiography? Angiography is a minimally invasive medical test that helps physicians diagnose and treat medical conditions. ...

  6. Role of Catheter-directed Thrombolysis in Management of Iliofemoral Deep Venous Thrombosis.

    Science.gov (United States)

    Chen, James X; Sudheendra, Deepak; Stavropoulos, S William; Nadolski, Gregory J

    2016-01-01

    The treatment for iliofemoral deep venous thrombosis (DVT) is challenging, as the use of anticoagulation alone can be insufficient for restoring venous patency and thus lead to prolongation of acute symptoms and an increased risk of chronic complications, including venous insufficiency and postthrombotic syndrome (PTS). In these cases, earlier and more complete thrombus removal can ameliorate acute symptoms and reduce long-term sequelae. Endovascular therapies involving the use of pharmacologic, mechanical, and combined pharmacomechanical modalities have been developed to achieve these goals. The most frequently used of these techniques, catheter-directed thrombolysis (CDT), involves the infusion of a thrombolytic agent through a multiple-side-hole catheter placed within the thrombosed vein to achieve high local doses and thereby break down the clot while minimizing systemic thrombolytic agent exposure. Randomized controlled trial results have indicated decreased PTS rates and improved venous patency rates in patients treated with CDT compared with these rates in patients treated with anticoagulation. The use of newer pharmacomechanical techniques, as compared with conventional CDT, reduces procedural times and thrombolytic agent doses and is the subject of ongoing investigations. Endovascular thrombus removal techniques offer a means to improve venous valvular function and decrease the risk of debilitating long-term complications such as PTS and are a promising option for treating patients with iliofemoral DVT. (©)RSNA, 2016.

  7. P02.03INCREASED COUNTS OF NK AND NKT CELLS ARE ASSOCIATED WITH PROLONGED SURVIVAL IN PRIMARY GLIOBLASTOMA PATIENTS TREATED WITH DENDRITIC CELL IMMUNOTHERAPY IN COMBINATION WITH RADIO- AND CHEMO-THERAPY

    Science.gov (United States)

    Pellegatta, S.; Eoli, M.; Cantini, G.; Anghileri, E.; Antozzi, C.; Frigerio, S.; Bruzzone, M.; Pollo, B.; Parati, E.; Finocchiaro, G.

    2014-01-01

    Two clinical studies, DENDR1 and DENDR2 including, respectively, the treatment of first diagnosis and recurrent glioblastoma (GB) patients with dendritic cells (DCs) loaded with autologous tumor lysate are currently active at Istituto Neurologico Besta, Milan. Our first results obtained on a group of recurrent GB patients demonstrated that the response of NK cells correlates with significantly prolonged survival. Here we provide results of the interim analysis on 22 patients affected by primary GB. Patients with post-surgery volume ≤10 cc underwent leukapheresis before radiotherapy and chemotherapy with temozolomide (TMZ). Three intradermal injections of mature DC were done before adjuvant chemotherapy. The subsequent 4 injections were performed 17 ± 3 days after adjuvant TMZ. MRI, clinical and immunological follow-up were performed every 2 months. The median age at surgery was 54.5 years (28-69). RT-TMZ induced significant lymphopenia (1000 lymphocytes/microl (5/22) before first vaccination had shorter PFS than others (p < 0.005). Peripheral Blood Lymphocytes (PBLs) were analyzed by flow cytometry to identify CD8+ T cells, NK and NKT cells before and after DC vaccines. The ratio of vaccination/baseline frequencies and counts (V/B ratio) of all of the immunological parameters for each patient was calculated, and the median of all of the observations used as the cut off value to separate patients. V/B ratio was correlated with the progression free survival (PFS) of each patient. Increased V/B ratio for NK cells and in particular NKT cells, but not for CD8 T lymphocytes, was significantly associated with prolonged PFS (median PFS 14 vs 8.0 mo, p = 0.01; 15.0 vs 8.0 mo, respectively). Interferon (IFN)-γ in PBLs was significantly higher in patients with PFS12 (p < 0.02), increasing immediately after the second vaccination as evaluated by real time-PCR. No changes in the expression levels of IFN-γ were observed in the other patients. After a median follow up of 14

  8. Management of Non- Deflating Foley Suprapubic Catheters - A ...

    African Journals Online (AJOL)

    The procedure described uses a 10 ml syringe and needle passed through the lumen of the catheter to puncture the inner surface of the catheter balloon and thus deflate it. Because the catheter balloon does not burst in this procedure there is no risk of balloon fragmentation or subsequent stone formation. The technique is ...

  9. The in vivo study on the radiobiologic effect of prolonged delivery time to tumor control in C57BL mice implanted with Lewis lung cancer

    International Nuclear Information System (INIS)

    Wang, Xin; Xiong, Xiao-Peng; Lu, Jiade; Zhu, Guo-Pei; He, Shao-Qin; Hu, Chao-Su; Ying, Hong-Mei

    2011-01-01

    High-precision radiation therapy techniques such as IMRT or sterotactic radiosurgery, delivers more complex treatment fields than conventional techniques. The increased complexity causes longer dose delivery times for each fraction. The purpose of this work is to explore the radiobiologic effect of prolonged fraction delivery time on tumor response and survival in vivo. 1-cm-diameter Lewis lung cancer tumors growing in the legs of C57BL mice were used. To evaluate effect of dose delivery prolongation, 18 Gy was divided into different subfractions. 48 mice were randomized into 6 groups: the normal control group, the single fraction with 18 Gy group, the two subfractions with 30 min interval group, the seven subfractions with 5 min interval group, the two subfractions with 60 min interval group and the seven subfractions with 10 min interval group. The tumor growth tendency, the tumor growth delay and the mice survival time were analyzed. The tumor growth delay of groups with prolonged delivery time was shorter than the group with single fraction of 18 Gy (P < 0.05). The tumor grow delay of groups with prolonged delivery time 30 min was longer than that of groups with prolonged delivery time 60 min P < 0.05). There was no significant difference between groups with same delivery time (P > 0.05). Compared to the group with single fraction of 18 Gy, the groups with prolonged delivery time shorten the mice survival time while there was no significant difference between the groups with prolonged delivery time 30 min and the groups with prolonged delivery time 60 min. The prolonged delivery time with same radiation dose shorten the tumor growth delay and survival time in the mice implanted with Lewis lung cancer. The anti-tumor effect decreased with elongation of the total interfractional time

  10. Prolongation of rat heart allografts by donor-specific blood transfusion treated with ultraviolet irradiation

    International Nuclear Information System (INIS)

    Oluwole, S.F.; Iga, C.; Lau, H.; Hardy, M.A.

    1985-01-01

    The effect of donor-specific blood transfusion was compared to that of UVB-irradiated donor-specific blood transfusion on heart allograft survival in inbred rats with major histocompatibility differences. In one series ACI rats received heterotopic heart grafts from Lewis rats and 1 mL transfusion of donor-type blood at 1, 2, and 3 weeks prior to the transplantation. Fifty percent of the grafts were permanently accepted (survival greater than 200 days). Following UVB-irradiated donor-specific blood transfusion, 55% of the grafts survived indefinitely. In a mixed lymphocyte reaction ACI lymphocytes are weak responders to Lewis lymphocytes. In another series, Lewis rats received ACI hearts. Donor-specific transfusions at 1, 2, and 3 weeks prior to transplantation did not significantly alter the survival of heart allografts. Lewis lymphocytes react strongly to ACI stimulator cells in a mixed lymphocyte reaction. However, when the donor blood was UVB-irradiated prior to transfusion, the ACI allograft survival was significantly prolonged in this ACI-to-Lewis strain combination. When Lewis rats received W/F hearts following either donor-specific or UVB-irradiated donor-specific transfusions, the hearts' survival was similarly and significantly prolonged, but did not become permanent. Mixed lymphocyte reaction reveals that the stimulation index of Lewis lymphocytes against W/F lymphocytes is greater than that of ACI versus Lewis, but is less than that between Lewis responder cells against ACI stimulators

  11. 21 CFR 880.5200 - Intravascular catheter.

    Science.gov (United States)

    2010-04-01

    ... Devices § 880.5200 Intravascular catheter. (a) Identification. An intravascular catheter is a device that consists of a slender tube and any necessary connecting fittings and that is inserted into the patient's vascular system for short term use (less than 30 days) to sample blood, monitor blood pressure, or...

  12. In vivo bioluminescence imaging for prolonged survival of transplanted human neural stem cells using 3D biocompatible scaffold in corticectomized rat model.

    Directory of Open Access Journals (Sweden)

    Do Won Hwang

    Full Text Available Stem cell-based treatment of traumatic brain injury has been limited in its capacity to bring about complete functional recovery, because of the poor survival rate of the implanted stem cells. It is known that biocompatible biomaterials play a critical role in enhancing survival and proliferation of transplanted stem cells via provision of mechanical support. In this study, we noninvasively monitored in vivo behavior of implanted neural stem cells embedded within poly-l-lactic acid (PLLA scaffold, and showed that they survived over prolonged periods in corticectomized rat model. Corticectomized rat models were established by motor-cortex ablation of the rat. F3 cells expressing enhanced firefly luciferase (F3-effLuc were established through retroviral infection. The F3-effLuc within PLLA was monitored using IVIS-100 imaging system 7 days after corticectomized surgery. F3-effLuc within PLLA robustly adhered, and gradually increased luciferase signals of F3-effLuc within PLLA were detected in a day dependent manner. The implantation of F3-effLuc cells/PLLA complex into corticectomized rats showed longer-lasting luciferase activity than F3-effLuc cells alone. The bioluminescence signals from the PLLA-encapsulated cells were maintained for 14 days, compared with 8 days for the non-encapsulated cells. Immunostaining results revealed expression of the early neuronal marker, Tuj-1, in PLLA-F3-effLuc cells in the motor-cortex-ablated area. We observed noninvasively that the mechanical support by PLLA scaffold increased the survival of implanted neural stem cells in the corticectomized rat. The image-guided approach easily proved that scaffolds could provide supportive effect to implanted cells, increasing their viability in terms of enhancing therapeutic efficacy of stem-cell therapy.

  13. Depressive disorders during weaning from prolonged mechanical ventilation.

    Science.gov (United States)

    Jubran, Amal; Lawm, Gerald; Kelly, Joanne; Duffner, Lisa A; Gungor, Gokay; Collins, Eileen G; Lanuza, Dorothy M; Hoffman, Leslie A; Tobin, Martin J

    2010-05-01

    Patients who require mechanical ventilation are at risk of emotional stress because of total dependence on a machine for breathing. The stress may negatively impact ventilator weaning and survival. The purpose of this study was to determine whether depressive disorders in patients being weaned from prolonged mechanical ventilation are linked to weaning failure and decreased survival. A prospective study of 478 consecutive patients transferred to a long-term acute care hospital for weaning from prolonged ventilation was undertaken. A clinical psychologist conducted a psychiatric interview to assess for the presence of depressive disorders. Of the 478 patients, 142 had persistent coma or delirium and were unable to be evaluated for depressive disorders. Of the remaining 336 patients, 142 (42%) were diagnosed with depressive disorders. In multivariate analysis, co-morbidity score [odds ratio (OR), 1.23; P = 0.007], functional dependence before the acute illness (OR, 1.70, P = 0.03) and history of psychiatric disorders (OR, 3.04, P = 0.0001) were independent predictors of depressive disorders. The rate of weaning failure was higher in patients with depressive disorders than in those without such disorders (61 vs. 33%, P = 0.0001), as was mortality (24 vs. 10%, P = 0.0008). The presence of depressive disorders was independently associated with mortality (OR, 4.3; P = 0.0002); age (OR, 1.06; P = 0.001) and co-morbidity score (OR, 1.24; P = 0.02) also predicted mortality. Depressive disorders were diagnosed in 42% of patients who were being weaned from prolonged ventilation. Patients with depressive disorders were more likely to experience weaning failure and death.

  14. Reducing unnecessary urinary catheter use and other strategies to prevent catheter-associated urinary tract infection: an integrative review.

    Science.gov (United States)

    Meddings, Jennifer; Rogers, Mary A M; Krein, Sarah L; Fakih, Mohamad G; Olmsted, Russell N; Saint, Sanjay

    2014-04-01

    Catheter-associated urinary tract infections (CAUTI) are costly, common and often preventable by reducing unnecessary urinary catheter (UC) use. To summarise interventions to reduce UC use and CAUTIs, we updated a prior systematic review (through October 2012), and a meta-analysis regarding interventions prompting UC removal by reminders or stop orders. A narrative review summarises other CAUTI prevention strategies including aseptic insertion, catheter maintenance, antimicrobial UCs, and bladder bundle implementation. 30 studies were identified and summarised with interventions to prompt removal of UCs, with potential for inclusion in the meta-analyses. By meta-analysis (11 studies), the rate of CAUTI (episodes per 1000 catheter-days) was reduced by 53% (rate ratio 0.47; 95% CI 0.30 to 0.64, pSMD) in catheterisation duration (days) was -1.06 overall (p=0.065) including a statistically significant decrease in stop-order studies (SMD -0.37; pSMD, -1.54; p=0.071). No significant harm from catheter removal strategies is supported. Limited research is available regarding the impact of UC insertion and maintenance technique. A recent randomised controlled trial indicates antimicrobial catheters provide no significant benefit in preventing symptomatic CAUTIs. UC reminders and stop orders appear to reduce CAUTI rates and should be used to improve patient safety. Several evidence-based guidelines have evaluated CAUTI preventive strategies as well as emerging evidence regarding intervention bundles. Implementation strategies are important because reducing UC use involves changing well-established habits.

  15. Selective lymphoid irradiation: III. Prolongation of cardiac xenografts and allografts in presensitized rats

    International Nuclear Information System (INIS)

    Hardy, M.A.; Oluwole, S.; Fawwaz, R.; Satake, K.; Nowygrod, R.; Reemtsma, K.

    1982-01-01

    Selective lymphoid irradiation (SLI) with palladium-109-hematoporphyrin (Pd-H) combined with antilymphocyte globulin (ALG) induces either donor-specific permanent rat heart allograft acceptance or significant allograft prolongation depending on the degree of donor-recipient matching. The purpose of this study was to determine if SLI combined with ALG can affect ACI heart allograft survival in Lewis recipients presensitized to ACI, and of hamster heart xenografts of Lewis rats. SLI combined with ALG delays allograft and xenograft rejection in the presence of induced or preformed antidonor antibodies, and converts primarily a humoral rejection into a cellular rejection by mechanisms as yet uncertain. Such peritransplant treatment had significant effect on the levels of antidonor complement-dependent cytotoxic antibody titers but did not correlate directly with graft survival. Histological analysis of rejected hearts in all groups demonstrated primarily a humoral hyperacute rejection in control animals and in recipients treated with ALG alone, while peritransplant treatment with Pd-H and ALG resulted not only in prolonged graft survival but histologically, primarily a cellular rejection of the graft

  16. Local Intravascular Drug Delivery: In Vitro Comparison of Three Catheter Systems

    International Nuclear Information System (INIS)

    Alfke, Heiko; Wagner, Hans-Joachim; Calmer, Christian; Klose, Klaus Jochen

    1998-01-01

    Purpose: The aim of this in vitro study was to compare different catheter systems for local drug delivery with respect to the penetration depth of a biotin marker solution delivered into the vessel wall. Methods: Post-mortem carotid arteries from pigs were locally infused with a biotin solution using three different catheter systems. With all catheters (microporous balloon catheter, hydrogel-coated balloon catheter, and spiral balloon catheter) we used the same pressure of 405 kPa (4 atm) and infusion times of 60, 90, and 300 sec. After infusion the arteries were histologically prepared and stained using a biotin-specific method. With a light microscope an observer, blinded to the catheter type, scored the amount of biotin within the vessel wall, measured as staining intensity, and the penetration depth of the biotin. Results: Delivery with the hydrogel-coated balloon catheter was limited to the intima and the innermost parts of the media. The spiral balloon and microporous balloon catheter showed both a deeper penetration and a larger amount of delivered biotin compared with the hydrogel catheter, with a slightly deeper penetration using the microporous catheter. The penetration depth showed a correlation with infusion time for the spiral balloon and microporous catheters, but not for the hydrogel-coated catheter. Conclusion: Different catheter designs lead to different patterns of local drug delivery. The differences in penetration depth and amount of the substance delivered to the vessel wall should be known and might be useful for targeting specific areas within the vessel wall

  17. Dose requirements for UVC disinfection of catheter biofilms

    DEFF Research Database (Denmark)

    Bak, Jimmy; Ladefoged, Søren D.; Tvede, Michael

    2009-01-01

    Bacterial biofilms on permanent catheters are the major sources of infection. Exposure to ultraviolet-C (UVC) light has been proposed as a method for disinfecting the inner surface of catheters. Specification of a UVC-based device for in vivo disinfection is based on the knowledge of the required...... doses to kill catheter biofilm. Given these doses and the power of available UVC light sources, calculation of the necessary treatment times is then possible. To determine the required doses, contaminated urinary catheters were used as test samples and UVC treated in vitro. Patient catheters (n = 67......) were collected and cut into segments of equal size and treated with various UVC doses. After treatment, the biofilm was removed by scraping and quantified by counting colony forming units. Percentage killing rates were determined by calculating ratios between UVC-treated samples and controls (no UVC...

  18. Miniaturization of catheter systems for angiography

    International Nuclear Information System (INIS)

    Hawkins, I.F. Jr.; Akins, E.W.

    1988-01-01

    The authors discuss the use of small catheters and needles in angiography and interventional procedures to improve the quality of the procedures and increase the success rate and safety. This philosophy was initially poorly received, both by operators and by industry; however, more recently microtechniques have become more acceptable primarily because of the changing economic climate requiring procedures with shorter or no hospitalization time. Since 1970, the authors have performed well over 10,000 angiographic procedures using 5 French catheters, or smaller. During the last 12 years, they have used almost exclusively 4 French catheters, primarily with standard filming techniques which have resulted in no thrombosed arteries, or significant hematoma formation

  19. Cryoballoon Catheter Ablation in Atrial Fibrillation

    Directory of Open Access Journals (Sweden)

    Cevher Ozcan

    2011-01-01

    Full Text Available Pulmonary vein isolation with catheter ablation is an effective treatment in patients with symptomatic atrial fibrillation refractory or intolerant to antiarrhythmic medications. The cryoballoon catheter was recently approved for this procedure. In this paper, the basics of cryothermal energy ablation are reviewed including its ability of creating homogenous lesion formation, minimal destruction to surrounding vasculature, preserved tissue integrity, and lower risk of thrombus formation. Also summarized here are the publications describing the clinical experience with the cryoballoon catheter ablation in both paroxysmal and persistent atrial fibrillation, its safety and efficacy, and discussions on the technical aspect of the cryoballoon ablation procedure.

  20. [Prevention of catheter-related infection: usefulness and cost-effectiveness of antiseptic catheters in children].

    Science.gov (United States)

    Lenz, Ana M; Vassallo, Juan C; Moreno, Guillermo E; Althabe, María; Gómez, Silvia; Magliola, Ricardo; Casimir, Lidia; Bologna, Rosa; Barretta, Jorge; Ruffa, Pablo

    2010-06-01

    To evaluate the cost-effectiveness of the antiseptic-impregnated catheter compared with conventional catheters in preventing catheter- related blood stream infections (CR-BSI). Cost-effectiveness analysis; clinical trial, experimental, randomized, controlled, prospective, open label. Patients and methods. A 172 patient cohort, under 1-year-old or less than 10 kg, postoperative cardiovascular children with central venous catheters (CVC) admitted to Cardiac Intensive Care Unit (UCI 35) at Hospital Nacional de Pediatría "Prof. Dr. Juan P. Garrahan", since September 2005 to December 2007. Demographic and CVC data were retrieved to compare: age, gender, weight, diagnosis, surgery, CVC days, costs and complications. Intervention. CVC Arrow, double-lumen, > 48 h of duration; intervention group: antiseptic-impregnated CVC vs. control group: CVC without antiseptics (conventional). The incidence of CR-IE (CR-Infected Events: colonization, local infection and/or CRBSI; combined end point) was 27% for antiseptic- impregnated CVC vs. 31% for conventional catheters (p= 0.6) with similar accumulated incidence of CR- BSI: 2.8 vs. 3.3 per 1000 dayscatheter. We found no differences between groups, except in weight: median 4.0 kg (r 2-17) vs. 4.7 kg (r 2-9) p= 0.0002 and age, median 2 months (r 1- 48) vs. 5 months (r 1- 24) p= 0.0019 in antiseptic-impregnated CVC group. These differences, though statistically significant were clinically non relevant. Median cost per patient during intensive care stay in the conventional CVC group was $3.417 (359-9.453) and in the antiseptic-impregnated-CVC group was $4.962 (239-24.532), p= 0.10. The use of antiseptic-impregnated CVC compared with conventional CVC did not decrease CR-BSI in this population. The cost per patients was higher in the antiseptic impregnated CVC group. These results do not support the routine use of this type of CVC in our population.

  1. Patency of Femoral Tunneled Hemodialysis Catheters and Factors Predictive of Patency Failure

    International Nuclear Information System (INIS)

    Burton, Kirsteen R.; Guo, Lancia L. Q.; Tan, Kong T.; Simons, Martin E.; Sniderman, Kenneth W.; Kachura, John R.; Beecroft, John R.; Rajan, Dheeraj K.

    2012-01-01

    Purpose: To determine the patency rates of and factors associated with increased risk of patency failure in patients with femoral vein tunneled hemodialysis catheters. Methods: All femoral tunneled catheter insertions from 1996 to 2006 were reviewed, during which time 123 catheters were inserted. Of these, 66 were exchanges. Patients with femoral catheter failure versus those with femoral catheter patency were compared. Confounding factors, such as demographic and procedural factors, were incorporated and assessed using univariate and multivariable Cox proportional hazards regression analyses. Results: Mean catheter primary patency failure time was 96.3 days (SE 17.9 days). Primary patency at 30, 60, 90, and 180 days was 53.8%, 45.4%, 32.1%, and 27.1% respectively. Crude rates of risk of catheter failure did not suggest a benefit for patients receiving catheters introduced from one side versus the other, but more cephalad location of catheter tip was associated with improved patency. Multivariate analysis showed that patients whose catheters were on the left side (p = 0.009), were of increasing age at the time of insertion (p = 0.002) and that those who had diabetes (p = 0.001) were at significantly greater risk of catheter failure. The catheter infection rate was 1.4/1000 catheter days. Conclusion: Patients who were of a more advanced age and had diabetes were at greater risk of femoral catheter failure, whereas those who received femoral catheters from the right side were less at risk of catheter failure.

  2. Use of monorail PTCA balloon catheter for local drug delivery.

    Science.gov (United States)

    Trehan, Vijay; Nair, Girish M; Gupta, Mohit D

    2007-01-01

    We report the use of monorail coronary balloon as an infusion catheter to give bailout abciximab selectively into the site of stent thrombosis as an adjunct to plain old balloon angioplasty (POBA) in a patient of subacute stent thrombosis of the left anterior descending coronary artery. The balloon component (polyamide material) of the monorail balloon catheter was shaved off the catheter so that abciximab injected through the balloon port of the catheter exited out the shaft of the balloon catheter at the site from where the balloon material was shaved off. We believe that selective infusion with abciximab along with POBA established antegrade flow and relieved the patient's ischemia. In the absence of essential hardware to give intracoronary drugs in an emergency situation, one may employ our technique of infusion through a monorail balloon catheter after shaving the balloon component from the catheter.

  3. Where does the pulmonary artery catheter float: Transesophageal echocardiography evaluation

    Directory of Open Access Journals (Sweden)

    Deepak K Tempe

    2015-01-01

    Full Text Available Background: Pulmonary artery (PA catheter provides a variety of cardiac and hemodynamic parameters. In majority of the patients, the catheter tends to float in the right pulmonary artery (RPA than the left pulmonary artery (LPA. We evaluated the location of PA catheter with the help of transesophageal echocardiography (TEE to know the incidence of its localization. Three views were utilized for this purpose; midesophageal ascending aorta (AA short-axis view, modified mid esophageal aortic valve long-axis view, and modified bicaval view. Methods: We enrolled 135 patients undergoing elective cardiac surgery where both the PA catheter and TEE were to be used; for this prospective observational study. PA catheter was visualized by TEE in the above mentioned views and the degree of clarity of visualization by three views was also noted. Position of the PA catheter was further confirmed by a postoperative chest radiograph. Results: One patient was excluded from the data analysis. PA catheter was visualized in RPA in 129 patients (96% and in LPA in 4 patients (3%. In 1 patient, the catheter was visualized in main PA in the chest radiograph. The midesophageal AA short-axis, modified aortic valve long-axis, and modified bicaval view provided good visualization in 51.45%, 57.4%, and 62.3% patients respectively. Taken together, PA catheter visualization was good in 128 (95.5% patients. Conclusion: We conclude that the PA catheter has a high probability of entering the RPA as compared to LPA (96% vs. 3% and TEE provides good visualization of the catheter in RPA.

  4. Prolonged survival and improved glycemia in BioBreeding diabetic rats after early sustained exposure to glucagon-like peptide 1.

    Science.gov (United States)

    Yanay, Ofer; Moralejo, Daniel; Kernan, Kelly; Brzezinski, Margaret; Fuller, Jessica M; Barton, Randall W; Lernmark, Ake; Osborne, William R

    2010-06-01

    Type 1 diabetes (T1D) in both humans and BioBreeding (BB) rats is an autoimmune disease that results in complete destruction of islets and insulin dependency for life. Glucagon-like peptide 1 (GLP-1) promotes beta cell proliferation and neogenesis and has a potent insulinotropic effect. We hypothesized that the expression of GLP-1 before disease onset would increase islet mass, delay diabetes and prolong survival of BB rats. Vascular smooth muscle cells retrovirally transduced to secrete GLP-1 were seeded into TheraCyte encapsulation devices, implanted subcutaneously, and rats were monitored for diabetes. In untreated control rats, plasma GLP-1 levels were 34.5-39.5 pmol/l, whereas, in treated rats, plasma levels were elevated, in the range 90-250.4 pmol/l. Hypoglycemia was not detected and this was anticipated from the glucose-regulated action of GLP-1. Diabetes onset (mean + or - SEM) in untreated rats occurred at 56.5 + or - 0.6 days (n = 6) and, in GLP-1-treated rats, was delayed until 76.4 + or - 3.3 days (n = 5) (p 650 mg/dl) and did not survive beyond 11 days. At 5 days after diabetes onset, insulin-secreting islets were absent in untreated rats. By contrast, treated rats maintained weight for up to 143 days of age and showed insulin-secreting beta cells. Sustained GLP-1 expression delivered by encapsulated cells before diabetes onset in BB rats showed an improved clinical outcome, suggesting the potential for treating patients using long lasting GLP-1 analogs.

  5. Central venous catheters: the role of radiology

    International Nuclear Information System (INIS)

    Tan, P.L.; Gibson, M.

    2006-01-01

    The insertion and management of long-term venous catheters have long been the province of anaesthetists, intensive care physicians and surgeons. Radiologists are taking an increasing role in the insertion of central venous catheters (CVCs) because of their familiarity with the imaging equipment and their ability to manipulate catheters and guide-wires. The radiological management of the complications of CVCs has also expanded as a result. This article reviews the role of radiology in central venous access, covering the detection and management of their complications

  6. Magnetic catheter manipulation in the interventional MR imaging environment.

    Science.gov (United States)

    Wilson, Mark W; Martin, Alastair B; Lillaney, Prasheel; Losey, Aaron D; Yee, Erin J; Bernhardt, Anthony; Malba, Vincent; Evans, Lee; Sincic, Ryan; Saeed, Maythem; Arenson, Ronald L; Hetts, Steven W

    2013-06-01

    To evaluate deflection capability of a prototype endovascular catheter, which is remotely magnetically steerable, for use in the interventional magnetic resonance (MR) imaging environment. Copper coils were mounted on the tips of commercially available 2.3-3.0-F microcatheters. The coils were fabricated in a novel manner by plasma vapor deposition of a copper layer followed by laser lithography of the layer into coils. Orthogonal helical (ie, solenoid) and saddle-shaped (ie, Helmholtz) coils were mounted on a single catheter tip. Microcatheters were tested in water bath phantoms in a 1.5-T clinical MR scanner, with variable simultaneous currents applied to the coils. Catheter tip deflection was imaged in the axial plane by using a "real-time" steady-state free precession MR imaging sequence. Degree of deflection and catheter tip orientation were measured for each current application. The catheter tip was clearly visible in the longitudinal and axial planes. Magnetic field artifacts were visible when the orthogonal coils at the catheter tip were energized. Variable amounts of current applied to a single coil demonstrated consistent catheter deflection in all water bath experiments. Changing current polarity reversed the observed direction of deflection, whereas current applied to two different coils resulted in deflection represented by the composite vector of individual coil activations. Microcatheter navigation through the vascular phantom was successful through control of applied current to one or more coils. Controlled catheter deflection is possible with laser lithographed multiaxis coil-tipped catheters in the MR imaging environment. Copyright © 2013 SIR. Published by Elsevier Inc. All rights reserved.

  7. Positioning of nasobiliary tube using magnet-loaded catheters.

    Science.gov (United States)

    Watanabe, Seitaro; Sato, Takamitsu; Kato, Shingo; Hosono, Kunihiro; Kobayashi, Noritoshi; Nakajima, Atsushi; Kubota, Kensuke

    2013-10-01

    In endoscopic nasobiliary drainage (ENBD), repositioning the catheter from the mouth to the nose is complicated. We devised a method using catheters with magnets and verified its utility and safety. We prospectively enrolled 20 patients undergoing ENBD at Yokohama City University Hospital. The procedures were successful in all 20 cases and no case required a change of operators to a senior doctor. The mean time for the procedure was 36.6 seconds. The emetic reflex was induced 0.5 times on average using the magnet method. The mean X-ray exposure time was 29.6 seconds. No complications occurred. The magnet-loaded catheter method for positioning the ENBD catheter before finally leading it through the nose took little time and was performed successfully and safely. Therefore, the magnet method could become the first choice among techniques for ENBD catheter placement. © Georg Thieme Verlag KG Stuttgart · New York.

  8. Intravascular catheter related infections in children admitted on the ...

    African Journals Online (AJOL)

    peripheral venous intravascular catheters uncoated with no antibiotic or antiseptic, was done. Social demographic characteristics, anthropometry, clinical examination including the catheter site were determined at enrollment. The children had their blood, catheter tip and hub samples taken off for culture and sensitivity as ...

  9. The importance of effective catheter securement.

    Science.gov (United States)

    Fisher, Jayne

    This article examines the importance of securing/fixing indwelling urinary catheters. The Oxford English dictionary interlinks the two words-'secure' and 'fix'-as having the same meaning. To secure the catheter should not be confused with 'support', whereby the weight of the urine drainage bag is supported with the use of velcro straps or a sleeve. The author introduces the need for the concept of this practice to be at the forefront of nurses' minds in all settings, and this is demonstrated through the use of case studies. Current guidance in this area is reviewed, as well as the problems that can arise when catheters are not secured properly and the available products for health professionals to use.

  10. Efficacy of a one-catheter concept for transradial coronary angiography.

    Directory of Open Access Journals (Sweden)

    Christoph Langer

    Full Text Available Transradial coronary angiography (TRC can be performed with a one-catheter approach for the right and left coronary ostium (R/LCO. We investigated the performance of a special diagnostic catheter widely used for the one-catheter-approach, the Tiger (Tiger II, TerumoTM.In a dual center registry we analyzed 1412 TRC-procedures exclusively performed by experienced TRC-operators. We compared the performance of the Tiger with Judkins catheters by retrospectively judging ostial catheter stability during contrast injection, and by measuring contrast use, fluoroscopy time (FT and complication rate.Poor or failed ostial engagement was found in 40.5% in the Tiger group, compared to 46.6% with the use of Judkins catheters (p<0.183. Ostial instability of the Tiger was found more often during engagement of the LCO than the RCO (34.4% vs. 10.8%, p<0.001, whereas it was similar in the LCO and RCO for Judkins catheters (27.4% vs. 26.7%, p = 0.840. TRC-procedures performed with Tiger catheters were associated with less contrast volume (63.48 ± 29.83mL vs. 82.51 ± 56.58mL, p<0.004 and shorter FT than with Judkins catheters. (198.27 ± 194.8sec vs. 326.85 ± 329.70sec. Forearm hematomas occurred less often with the Tiger (1.2% vs. 6.6%, p< 0.02.The Tiger employed as a single catheter in TRC is an effective tool to achieve lower contrast volume and fluoroscopy time at a low complication rate. Unstable engagement affects predominantly the left coronary artery, but its overall frequency is similar for both, the Tiger and Judkins catheters.

  11. Medical Aspects of Survival: Training for Aircrew

    Science.gov (United States)

    1983-01-01

    injuries. External antiseptics ( benzalkonium chloride tincture, etc.) are best used for cleaning abrasions, scratches and the skin areas adjacent to...the stump. The reduction of fractures is normally considered beyond the scope of first-aid ; how- ever^ in the prolonged survival situation, the... reduction to ensure the proper alignment of the bones. L _-., J Improvised Casts. As plaster casts are not available in the survival situation, the

  12. Study comparing 3 hour and 24 hour post-operative removal of bladder catheter and vaginal pack following vaginal surgery: a randomised controlled trial.

    Science.gov (United States)

    Rajan, Priya; Soundara Raghavan, S; Sharma, Deepak

    2017-09-11

    Traditional practice after vaginal hysterectomy was to keep the vaginal pack and urinary catheter for 24 hours post operatively. But there were studies that prolonged cathterisation was associated with urinary infection. So this study was conducted to compare the post operative outcome when the urinary catheter and vaginal pack were removed after 3 hours and after 24 hours after surgery. The study was done in the Department of Obstetrics and Gynecology, in a tertiary teaching institute of South India from September 2008 to March 2010. It was a randomised controlled trial involving 200 women undergoing vaginal surgery, who were randomly assigned to 2 groups - catheter and vaginal pack were removed either in 3 h in study group or were removed in 24 h in control group. The outcome of the study were vaginal bleeding, urinary retention, febrile morbidity, and urinary infection. There was no significant difference between the study and control groups with respect to vaginal bleeding (0 and 1%, p = 1), urinary retention (9 and 4%, p = 0.15), febrile morbidity (7 and 4%, p = 0.35), and urinary infection (26% in each group, p = 1.0). Keeping the urinary catheter and vaginal pack for 24 h following vaginal surgery does not offer any additional benefit against removing them after 3 h.

  13. Feedforward Coordinate Control of a Robotic Cell Injection Catheter.

    Science.gov (United States)

    Cheng, Weyland; Law, Peter K

    2017-08-01

    Remote and robotically actuated catheters are the stepping-stones toward autonomous catheters, where complex intravascular procedures may be performed with minimal intervention from a physician. This article proposes a concept for the positional, feedforward control of a robotically actuated cell injection catheter used for the injection of myogenic or undifferentiated stem cells into the myocardial infarct boundary zones of the left ventricle. The prototype for the catheter system was built upon a needle-based catheter with a single degree of deflection, a 3-D printed handle combined with actuators, and the Arduino microcontroller platform. A bench setup was used to mimic a left ventricle catheter procedure starting from the femoral artery. Using Matlab and the open-source video modeling tool Tracker, the planar coordinates ( y, z) of the catheter position were analyzed, and a feedforward control system was developed based on empirical models. Using the Student's t test with a sample size of 26, it was determined that for both the y- and z-axes, the mean discrepancy between the calibrated and theoretical coordinate values had no significant difference compared to the hypothetical value of µ = 0. The root mean square error of the calibrated coordinates also showed an 88% improvement in the z-axis and 31% improvement in the y-axis compared to the unmodified trial run. This proof of concept investigation leads to the possibility of further developing a feedfoward control system in vivo using catheters with omnidirectional deflection. Feedforward positional control allows for more flexibility in the design of an automated catheter system where problems such as systemic time delay may be a hindrance in instances requiring an immediate reaction.

  14. An intervention to improve the catheter associated urinary tract infection rate in a medical intensive care unit: Direct observation of catheter insertion procedure.

    Science.gov (United States)

    Galiczewski, Janet M; Shurpin, Kathleen M

    2017-06-01

    Healthcare associated infections from indwelling urinary catheters lead to increased patient morbidity and mortality. The purpose of this study was to determine if direct observation of the urinary catheter insertion procedure, as compared to the standard process, decreased catheter utilization and urinary tract infection rates. This case control study was conducted in a medical intensive care unit. During phase I, a retrospective data review was conducted on utilsiation and urinary catheter infection rates when practitioners followed the institution's standard insertion algorithm. During phase II, an intervention of direct observation was added to the standard insertion procedure. The results demonstrated no change in utilization rates, however, CAUTI rates decreased from 2.24 to 0 per 1000 catheter days. The findings from this study may promote changes in clinical practice guidelines leading to a reduction in urinary catheter utilization and infection rates and improved patient outcomes. Copyright © 2016 Elsevier Ltd. All rights reserved.

  15. Psychotropic Pharmacotherapy Associated With QT Prolongation Among Veterans With Posttraumatic Stress Disorder.

    Science.gov (United States)

    Stock, Eileen M; Zeber, John E; McNeal, Catherine J; Banchs, Javier E; Copeland, Laurel A

    2018-04-01

    In 2012, the Food and Drug Administration issued Drug Safety Communications on several drugs associated with QT prolongation and fatal ventricular arrhythmias. Among these was citalopram, a selective serotonin reuptake inhibitor (SSRI) approved for depression and commonly used for posttraumatic stress disorder (PTSD). Evaluation of the risk for QT prolongation among other psychotropic drugs for individuals with PTSD remains limited. Explore psychotropic drugs associated with QT prolongation among veterans with PTSD. Patients in the Veterans Health Administration in 2006-2009 with PTSD and QT prolongation (176 cases) were matched 1:4 on age, gender, visit date and setting, and physical comorbidity. Classification trees assessed QT prolongation risk among prescribed medications (n=880). Receipt of any drug with known risk of QT prolongation varied by group (23% QT cases vs 15% control, prisks included ziprasidone (3% vs 1%, p=0.02) and buspirone (6% vs 2%, p=0.01). Increased risk was not observed for the SSRIs, citalopram and fluoxetine. Classification trees found that sotalol and amitriptyline carried greater risk among cardiac patients and methadone, especially if prescribed with quetiapine, among noncardiac patients. Per adjusted survival model, patients with QT prolongation were at increased risk for death (hazard ratio=1.60; 95% CI=1.04-2.44). Decision models are particularly advantageous when exploring nonlinear relationships or nonadditive interactions. These findings may potentially affect clinical decision-making concerning treatment for PTSD. For patients at higher risk of QT prolongation, antidepressants other than amitriptyline should be considered. Medications for comorbid conditions should also be closely monitored for heightened QT prolongation risk.

  16. Femoral venous catheters: a safe alternative for delivering parenteral alimentation.

    Science.gov (United States)

    Friedman, B; Kanter, G; Titus, D

    1994-04-01

    Femoral vein catheterization is an alternative method of obtaining central venous access. Placement of femoral venous catheters (FVCs) is possible in the majority of patients, suitable for most indications, and associated with a low complication rate during insertion. We wished to determine the incidence of infections or other complications resulting when parenteral nutrition was delivered through FVCs. Fifty-two patients were followed from a hospital-wide population including patients in the critical care units. Triple-lumen catheters were placed by using the sterile Seldinger technique, and sites were examined daily for inflammation. Bacteriologic surveillance was accomplished by submitting the catheter tip for semiquantitative cultures. If catheter line sepsis was suspected, blood samples for cultures were drawn through the catheter and peripherally. The rate of occurrence of colonized catheters was 9.6% (five of 52), and catheter sepsis was found in one case (1.9%). Other than inflammation at six (11.5%) of 52 catheter sites, noninfectious complications of FVCs were not found. On the basis of these findings, we consider FVC-delivered parenteral alimentation a safe and effective alternative to other forms of central venous access.

  17. The in vivo study on the radiobiologic effect of prolonged delivery time to tumor control in C57BL mice implanted with Lewis lung cancer

    Directory of Open Access Journals (Sweden)

    Zhu Guo-Pei

    2011-01-01

    Full Text Available Abstract Background High-precision radiation therapy techniques such as IMRT or sterotactic radiosurgery, delivers more complex treatment fields than conventional techniques. The increased complexity causes longer dose delivery times for each fraction. The purpose of this work is to explore the radiobiologic effect of prolonged fraction delivery time on tumor response and survival in vivo. Methods 1-cm-diameter Lewis lung cancer tumors growing in the legs of C57BL mice were used. To evaluate effect of dose delivery prolongation, 18 Gy was divided into different subfractions. 48 mice were randomized into 6 groups: the normal control group, the single fraction with 18 Gy group, the two subfractions with 30 min interval group, the seven subfractions with 5 min interval group, the two subfractions with 60 min interval group and the seven subfractions with 10 min interval group. The tumor growth tendency, the tumor growth delay and the mice survival time were analyzed. Results The tumor growth delay of groups with prolonged delivery time was shorter than the group with single fraction of 18 Gy (P 0.05. Compared to the group with single fraction of 18 Gy, the groups with prolonged delivery time shorten the mice survival time while there was no significant difference between the groups with prolonged delivery time 30 min and the groups with prolonged delivery time 60 min. Conclusions The prolonged delivery time with same radiation dose shorten the tumor growth delay and survival time in the mice implanted with Lewis lung cancer. The anti-tumor effect decreased with elongation of the total interfractional time.

  18. Monorail Piccolino catheter: a new rapid exchange/ultralow profile coronary angioplasty system.

    Science.gov (United States)

    Mooney, M R; Douglas, J S; Mooney, J F; Madison, J D; Brandenburg, R O; Fernald, R; Van Tassel, R A

    1990-06-01

    The Monorail Piccolino coronary angioplasty balloon catheter (MBC) was evaluated on 118 patients at two centers. Technical success was achieved in 110 patients (93%). Time for catheter exchange and total fluoroscopy time were significantly lower for the Monorail catheter than with standard equipment (exchange time 97 vs. 170 seconds P less than .05 and fluoroscopy time 17 vs. 88 seconds P less than .001). The advantages of rapid exchange and the ability of utilize 2 Monorail balloon catheters through one 9F guiding catheter for simultaneous inflations allowed for maximal flexibility in treating patients with bifurcation lesions. The double wire approach utilizing one Monorail balloon catheter with a 7F guiding catheter was also technically successful. The Monorail Piccolino balloon catheter has unique features that allow for greater ease of operator use, rapid catheter exchange, and optimal angiographic visualization. It is felt that this catheter design provides distinct advantages over standard angioplasty equipment.

  19. Radiographic signs of non-venous placement of intended central venous catheters in children

    Energy Technology Data Exchange (ETDEWEB)

    Taylor, Erin C. [Boston Children' s Hospital, Department of Radiology, Boston, MA (United States); Taylor, George A. [Boston Children' s Hospital, Department of Radiology, Boston, MA (United States); Harvard Medical School, Department of Radiology, Boston, MA (United States)

    2016-02-15

    Central venous catheters (CVCs) are commonly used in children, and inadvertent arterial or extravascular cannulation is rare but has potentially serious complications. To identify the radiographic signs of arterial placement of CVCs. We retrospectively reviewed seven cases of arterially malpositioned CVCs on chest radiograph. These cases were identified through departmental quality-assurance mechanisms and external consultation. Comparison of arterial cases was made with 127 age-matched chest radiographs with CVCs in normal, expected venous location. On each anteroposterior (AP) radiograph we measured the distance of the catheter tip from the right lateral border of the thoracic spine, and the angle of the vertical portion of the catheter relative to the midline. On each lateral radiograph we measured the angle of the vertical portion of each catheter relative to the anterior border of the thoracic spine. When bilateral subclavian catheters were present, the catheter tips were described as crossed, overlapping or uncrossed. On AP radiographs, arterially placed CVCs were more curved to the left, with catheter tip positions located farther to the left of midline than normal venous CVCs. When bilateral, properly placed venous catheters were present, all catheters crossed at the level of the superior vena cava (SVC). When one of the bilateral catheters was in arterial position, neither of the catheters crossed or the inter-catheter crossover distance was exaggerated. On lateral radiographs, there was a marked anterior angulation of the vertical portion of the catheter (mean angle 37 ± 15 standard deviation [SD] in arterial catheters versus 5.9 ± 8.3 SD in normally placed venous catheters). Useful radiographic signs suggestive of unintentional arterial misplacement of vascular catheters include leftward curvature of the vertical portion of the catheter, left-side catheter tip position, lack of catheter crossover on the frontal radiograph, as well as exaggerated

  20. Catheter-Related Sepsis Due to Rhodotorula glutinis

    Science.gov (United States)

    Hsueh, Po-Ren; Teng, Lee-Jene; Ho, Shen-Wu; Luh, Kwen-Tay

    2003-01-01

    We describe a central venous catheter-related (Port-A-Cath; Smiths Industries Medical Systems [SIMS] Deltec, Inc., St. Paul, Minn.) infection caused by Rhodotorula glutinis in a 51-year-old man with nasopharyngeal carcinoma. He was treated with fluconazole for 8 weeks and had the catheter removed. Two isolates of R. glutinis recovered from blood specimens (one obtained via peripheral veins and one via the catheter) before administration of fluconazole and one recovered from the removed catheter 17 days after initiation of fluconazole therapy exhibited high-level resistance to fluconazole (MICs, >256 μg/ml). These three isolates were found to belong to a single clone on the basis of identical antibiotypes determined by the E test (PDM Epsilometer; AB Biodisk, Solna, Sweden) and biotypes determined by API ID32 C (bioMerieux, Marcy I'Etoile, France) and their identical random amplified polymorphic DNA patterns. PMID:12574300

  1. Tanshinone IIA inhibits metastasis after palliative resection of hepatocellular carcinoma and prolongs survival in part via vascular normalization

    Directory of Open Access Journals (Sweden)

    Wang Wen-Quan

    2012-11-01

    Full Text Available Abstract Background Promotion of endothelial normalization restores tumor oxygenation and obstructs tumor cells invasion, intravasation, and metastasis. We therefore investigated whether a vasoactive drug, tanshinone IIA, could inhibit metastasis by inducing vascular normalization after palliative resection (PR of hepatocellular carcinoma (HCC. Methods A liver orthotopic double-tumor xenograft model in nude mouse was established by implantation of HCCLM3 (high metastatic potential and HepG2 tumor cells. After removal of one tumor by PR, the effects of tanshinone IIA administration on metastasis, tumor vascularization, and survival were evaluated. Tube formation was examined in mouse tumor-derived endothelial cells (TECs treated with tanshinone IIA. Results PR significantly accelerated residual hepatoma metastases. Tanshinone IIA did not inhibit growth of single-xenotransplanted tumors, but it did reduce the occurrence of metastases. Moreover, it inhibited PR-enhanced metastases and, more importantly, prolonged host survival. Tanshinone IIA alleviated residual tumor hypoxia and suppressed epithelial-mesenchymal transition (EMT in vivo; however, it did not downregulate hypoxia-inducible factor 1α (HIF-1α or reverse EMT of tumor cells under hypoxic conditions in vitro. Tanshinone IIA directly strengthened tube formation of TECs, associated with vascular endothelial cell growth factor receptor 1/platelet derived growth factor receptor (VEGFR1/PDGFR upregulation. Although the microvessel density (MVD of residual tumor tissue increased after PR, the microvessel integrity (MVI was still low. While tanshinone IIA did not inhibit MVD, it did dramatically increase MVI, leading to vascular normalization. Conclusions Our results demonstrate that tanshinone IIA can inhibit the enhanced HCC metastasis associated with PR. Inhibition results from promoting VEGFR1/PDGFR-related vascular normalization. This application demonstrates the potential clinical

  2. Number and location of drainage catheter side holes: in vitro evaluation.

    Science.gov (United States)

    Ballard, D H; Alexander, J S; Weisman, J A; Orchard, M A; Williams, J T; D'Agostino, H B

    2015-09-01

    To evaluate the influence of number and location of catheter shaft side holes regarding drainage efficiency in an in vitro model. Three different drainage catheter models were constructed: open-ended model with no side holes (one catheter), unilateral side hole model (six catheters with one to six unilateral side holes), and bilateral side hole model (six catheters with one to six bilateral side holes). Catheters were inserted into a drainage output-measuring device with a constant-pressure reservoir of water. The volume of water evacuated by each of the catheters at 10-second intervals was measured. A total of five trials were performed for each catheter. Data were analysed using one-way analysis of variance. The open-ended catheter had a mean drainage volume comparable to the unilateral model catheters with three, four, and five side holes. Unilateral model catheters had significant drainage volume increases up to three side holes; unilateral model catheters with more than three side holes had no significant improvement in drainage volume. All bilateral model catheters had significantly higher mean drainage volumes than their unilateral counterparts. There was no significant difference between the mean drainage volume with one, two, or three pairs of bilateral side holes. Further, there was no drainage improvement by adding additional bilateral side holes. The present in vitro study suggests that beyond a critical side hole number threshold, adding more distal side holes does not improve catheter drainage efficiency. These results may be used to enhance catheter design towards improving their drainage efficiency. Copyright © 2015 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.

  3. Suprapubic catheter care

    Science.gov (United States)

    ... going back into your bladder. Try not to disconnect the catheter more than you need to. Keeping ... Copyright Privacy Accessibility Quality Guidelines Viewers & Players MedlinePlus Connect for EHRs For Developers U.S. National Library of ...

  4. Survival with breast cancer: the importance of estrogen receptor quantity.

    Science.gov (United States)

    Shek, L L; Godolphin, W

    1989-02-01

    The survival of 1184 British Columbian women whose primary breast cancers were diagnosed and assayed for estrogen receptor (ER) between 1975 and 1981 was studied. Median follow-up was 60 months. ER concentrations yielded greater prognostic information than simple positive and negative categories. When ER data were divided into four strata: less than or equal to 1, 2-9, 10-159 and greater than or equal to 160 fmol/mg cytosol protein, the association of higher ER with prolonged survival was highly significant (P less than 0.0001) and independent of TNM stage, nodal status and menopausal status. ER less than or equal to 1 and ER = 2-9 groups were distinct with respect to overall disease-specific survival. Patient age did not predict survival when controlled for ER. Prolonged recurrence-free survival was associated with higher ER (P = 0.0001) for at least 5 years after diagnosis. This significant trend persisted after adjustments for nodal status, TNM stage, menopausal status and the type of systemic adjuvant therapy.

  5. Prolongation of experimental islet transplant survival by fractionated splenic irradiation

    International Nuclear Information System (INIS)

    Kolb, E.; Casanova, M.; Largiader, F.

    1980-01-01

    Experiments designed to delay the rejection of intrasplenic pancreatic fragment allotransplants in dogs showed increased transplant survival times from 3.1 days (controls) to 5.5 days with fractionated splenic irradiation and to 7.5 days with combined local irradiation and immunosuppressive chemotherapy. Drug treatment alone had no beneficial effect

  6. Three-Catheter Technique for Ablation of Left-Sided Accessory Pathways in Wolff-Parkinson-White is Less Expensive and Equally Successful When Compared to a Five-Catheter Technique.

    Science.gov (United States)

    Capone, Christine A; Ceresnak, Scott R; Nappo, Lynn; Gates, Gregory J; Schechter, Clyde B; Pass, Robert H

    2015-12-01

    To compare the efficacy, safety, and cost-effectiveness of a three-catheter approach with a conventional five-catheter approach for the mapping and ablation of supraventricular tachycardia in pediatric patients with Wolff-Parkinson-White Syndrome (WPW) and concealed accessory pathways (APs). A retrospective review from 2008 to 2012 of patients less than 21 years with WPW who underwent a three-catheter radiofrequency (RF) ablation of a left-sided AP (ablation, right ventricular [RV] apical, and coronary sinus [CS] decapolar catheters) was performed. The three-catheter group was compared to a control group who underwent a standard five-catheter (ablation, RV apical, CS decapolar, His catheter, and right atrial catheter) ablation for the treatment of left-sided WPW or concealed AP. Demographics, ablation outcomes, and costs were compared between groups. Twenty-eight patients met inclusion criteria with 28 control patients. The groups did not differ in gender, age, weight, or body surface area. Locations of the AP on the mitral annulus were similar between the groups. All patients were ablated via transseptal approach. Note that 28 of 28 in the three-catheter group (100%) and 27 of 28 (96%) controls were acutely successfully ablated (P = 0.31). No complications were encountered. There was no difference in procedural time, time to loss of AP conduction, or number of RF applications. Use of the three-catheter technique resulted in a total savings of $2,465/case, which includes the $680 savings from using fewer catheters as well as the savings from a shortened procedure time. Ablation in patients with WPW and a left-sided AP can be performed using three catheters with similar efficacy and safety while offering significant cost savings compared to a conventional five-catheter approach. © 2015 Wiley Periodicals, Inc.

  7. Balloon-tipped flow-directed catheters

    International Nuclear Information System (INIS)

    Ganz, P.; Swan, H.J.C.; Ganz, W.

    1986-01-01

    Diagnostic catheterization of the right side of the heart with semirigid cardiac catheters requires fluoroscopic guidance and substantial skill. Abnormal positions of the heart chambers and of the great vessels associated with cardiac dilatation or with congenital malformation present difficulties even to experienced laboratory cardiologists. These problems have been largely overcome by the introduction of balloon tipped flow directed catheters, which allow for rapid and relatively safe catheterization of the pulmonary artery without fluoroscopy. It was through the application of these catheters in the intensive care unit that the many pitfalls in the clinical assessment of hemodynamic disturbances became apparent. Although S3 gallop sounds may be useful in the clinical recognition of chronic ventricular failure, their presence or absence has limited predictive value in estimating left ventricular filling pressure in myocardial infarction. Information derived from right heart catheterization is often pivotal in the evaluation of hemodynamic disorders, in directing treatment, and in monitoring the results of therapy in critically ill patients

  8. Translumbar aortography by catheter technique

    International Nuclear Information System (INIS)

    Hagen, B.; Honemeyer, U.; Meier-Duis, H.

    1982-01-01

    400 examinations performed during the last three years by TLA (only catheter technique) were subjected to critical analysis and studied particularly in respect to the rate of complications. We observed 13 complications (3.25%) of moderate severity, including 3 large hematomas (documented by CT), 3 paravasations and 7 dissections, but no fatal complication. Two (0.5%) of these complications had clinical evidence. The advantages of the catheter technique of TLA are described. Injections through rigid metal cannula should be avoided because of the high incidence of complications (mainly the increased risk of dissection). Downstream injection resulted in excellent visualization of peripheral occluding vascular disease. Upstream injection should be preferred to demonstrate the major abdominal arteries as well as supraceliac collateral circulation in the case of high Leriche syndrome. The low or intermediate puncture of the aorta is preferable to facilitate caudad direction of the catheter and to diminish the risk of damaging other vessels or puncturing an organ. (orig.) [de

  9. Catheter-associated UTI

    Science.gov (United States)

    ... UTI; Health care-associated UTI; Catheter-associated bacteriuria; Hospital acquired-UTI Images Bladder catheterization, female Bladder catheterization, male References Calfee DP. Prevention and control of health care-associated infections. In: Goldman L, Schafer AI, eds. Goldman's Cecil ...

  10. Outcome of tunneled infusion catheters inserted via the right internal jugular vein

    International Nuclear Information System (INIS)

    Shin, Sung Wook; Do, Young Soo; Choo, Sung Wook; Yoo, Wi Kang; Choo, In Wook; Kim, Jae Hyung

    2003-01-01

    To assess the outcome of tunneled central venous catheter placement via the right internal jugular vein. Between June 2001 and May 2002, 670 consecutive Hickman catheters were placed in 654 patients via the right internal jugular vein. The procedural complications arising and follow-up data obtained from May to July 2002 were evaluated. The technical success rate for catheter placement was 99.9% (669/670). Procedural complications were limited to eight cases (1.2%), including three pneumothoraces, one early migration of the catheter, one clinically unimportant air embolism, one catheter injury, one catheter kinking and one primary malpositioning in the azygos vein. Catheter dwelling time ranged from 1 to 407 (mean 107.1) days. During the follow-up period, 416 catheter were removed for various reasons: treatment had ended (n=334), patients declined treatment or their drug regimen was changed (n=16), late complications arose (n=53), or other circumstances intervened (n=13). Late complications included 44 cases of catheter-related infection (6.6%), five of catheter migration (0.7%), two of catheter occlusion (0.3%), one of thrombophlebitis (0.15%), and one of catheter-related right atrial thrombosis (0.15%). Only one instance of symptomatic venous thrombosis or stenosis was noted, namely the one case of thrombophlebitis. Because the incidence of subsequent symptomatic venous thrombosis or stenosis is lower, the preferred route for tunneled central venous catheter placement is the right internal jugular vein

  11. A computational fluid dynamics simulation framework for ventricular catheter design optimization.

    Science.gov (United States)

    Weisenberg, Sofy H; TerMaath, Stephanie C; Barbier, Charlotte N; Hill, Judith C; Killeffer, James A

    2017-11-10

    OBJECTIVE Cerebrospinal fluid (CSF) shunts are the primary treatment for patients suffering from hydrocephalus. While proven effective in symptom relief, these shunt systems are plagued by high failure rates and often require repeated revision surgeries to replace malfunctioning components. One of the leading causes of CSF shunt failure is obstruction of the ventricular catheter by aggregations of cells, proteins, blood clots, or fronds of choroid plexus that occlude the catheter's small inlet holes or even the full internal catheter lumen. Such obstructions can disrupt CSF diversion out of the ventricular system or impede it entirely. Previous studies have suggested that altering the catheter's fluid dynamics may help to reduce the likelihood of complete ventricular catheter failure caused by obstruction. However, systematic correlation between a ventricular catheter's design parameters and its performance, specifically its likelihood to become occluded, still remains unknown. Therefore, an automated, open-source computational fluid dynamics (CFD) simulation framework was developed for use in the medical community to determine optimized ventricular catheter designs and to rapidly explore parameter influence for a given flow objective. METHODS The computational framework was developed by coupling a 3D CFD solver and an iterative optimization algorithm and was implemented in a high-performance computing environment. The capabilities of the framework were demonstrated by computing an optimized ventricular catheter design that provides uniform flow rates through the catheter's inlet holes, a common design objective in the literature. The baseline computational model was validated using 3D nuclear imaging to provide flow velocities at the inlet holes and through the catheter. RESULTS The optimized catheter design achieved through use of the automated simulation framework improved significantly on previous attempts to reach a uniform inlet flow rate distribution using

  12. [Recording of ventricular pressure by conventional catheter manometer systems. Efficiency of several combinations of conventional catheters, modern transducers and catheter-flush systems (author's transl)].

    Science.gov (United States)

    Hellige, G

    1976-01-01

    The experimentally in vitro determined dynamic response characteristics of 38 catheter manometer systems were uniform in the worst case to 5 c.p.s. and optimally to 26 c.p.s. Accordingly, some systems are only satisfactory for ordinary pressure recording in cardiac rest, while better systems record dp/dt correct up to moderate inotropic stimulation of the heart. In the frequency range of uniform response (amplitude error less +/- 5%) the phase distortion is also negligible. In clinical application the investigator is often restricted to special type of cardiac catheter. In this case a low compliant transducer yields superior results. In all examined systems the combination with MSD 10 transducers is best, whereas the combination with P 23 Db transducers leads to minimal results. An inadequate system for recording ventricular pressure pulses leads in most cases to overestimations of dp/dtmax. The use of low frequency pass filters to attenuate higher frequency artefacts is, under clinical conditions, not suitable for extending the range of uniform frequency response. The dynamic response of 14 catheter manometer systems with two types of continuous self flush units was determined. The use of the P 37 flush unit in combination with small internal diameter catheters leads to serious error in ordinary pressure recording, due to amplitude distortion of the lower harmonics. The frequency response characteristics of the combination of an Intraflow flush system and MSD 10 transducer was similar to the non-flushing P 23 Db transducer feature.

  13. Compatibility of electrolytically produced sodium hypochlorite solutions on long- term implanted dialysis catheters.

    Science.gov (United States)

    Mishkin, G J

    2007-01-01

    More than 20% of the world's population use a catheter for dialysis, despite guidelines limiting their use. Although the structure and design of the catheters differ by manufacturer, the material used in central venous catheters and peritoneal dialysis catheters are the same across manufacturers. Given the long-term use of these catheters in the dialysis population, the good compatibility of the antiseptics and disinfectants used on the catheters is imperative to prevent failure and cracking of the catheter material. Tensile strengths of commercially available catheters were measured after exposure to commonly used disinfectants. The tensile strength was then compared between the catheters by analyzing the displacement vs. force (N) curves produced during the evaluation. A total of 44 catheter lumens were evaluated. The electrolytically produced sodium hypochlorite solution, Alcavis 50/ExSept Plus, was the only solution shown to be compatible with all three catheter materials resulting in a deviation of less than 10% for each of the different catheter types. Electrolytically produced sodium hypochlorite solutions were the only solutions in this study that did not alter the physical properties of any of the catheters after long-term exposure.

  14. Percutaneous untying of a knot in a retained Swan-Ganz catheter

    International Nuclear Information System (INIS)

    Bhatti, Waqar A.; Sinha, Sankar; Rowlands, Peter

    2000-01-01

    A patient was referred to us with a tightly knotted Swan-Ganz catheter. The catheter could not be removed by conventional simple methods. We describe a minimally invasive means of removal of the catheter using an Amplatz gooseneck snare and an angioplasty balloon. This allowed the Catheter to be removed without trauma.

  15. Dialysis catheter-related septicaemia--focus on Staphylococcus aureus septicaemia

    DEFF Research Database (Denmark)

    Nielsen, J; Ladefoged, S D; Kolmos, H J

    1998-01-01

    BACKGROUND: Dialysis catheters are a common cause of nosocomial septicaemia in haemodialysis units usually due to staphylococci, of which Staphylococcus aureus is the most pathogenic. In this study, the epidemiology and pathogenesis of dialysis catheter-related infections were studied, and methods...... to infection were measured. After catheter insertion, all patients were screened for nasal carriage of S. aureus, and a culture was taken from the skin overlying the catheter insertion site. Once a week, cultures were taken from the insertion site and from the hub, and aerobic and anaerobic blood cultures were...... drawn from the catheter. If clinical signs of septicaemia occurred, peripheral blood cultures were also performed, when it was possible. RESULTS: The incidence of septicaemia was 49% (21/43) in patients, and 56% of all cases were caused by S. aureus. The mortality was 14% (3/21) and the incidence...

  16. Radiological Tenckhoff catheter insertion for peritoneal dialysis: A cost-effective approach.

    Science.gov (United States)

    Lee, James; Mott, Nigel; Mahmood, Usman; Clouston, John; Summers, Kara; Nicholas, Pauline; Gois, Pedro Henrique França; Ranganathan, Dwarakanathan

    2018-04-01

    Radiological insertion of Tenckhoff catheters can be an alternative option for peritoneal dialysis access creation, as compared to surgical catheter insertion. This study will review the outcomes and complications of radiological Tenckhoff catheter insertion in a metropolitan renal service and compare costs between surgical and radiological insertion. Data were collected prospectively for all patients who had a Tenckhoff catheter insertion for peritoneal dialysis (PD) under radiological guidance at our hospital from May 2014 to November 2016. The type of catheter used and complications, including peri-catheter leak, exit site infection and peritonitis were reviewed. Follow-up data were also collected at points 3, 6 and 12 months from catheter insertion. Costing data were obtained from Queensland Health Electronic Reporting System (QHERS) data, average staff salaries and consumable contract price lists. In the 30-month evaluation period, 70 catheters were inserted. Two patients had an unsuccessful procedure due to the presence of abdominal adhesions. Seven patients had an episode of peri-catheter leak, and four patients had an exit site infection following catheter insertion. Peritonitis was observed in nine patients during the study period. The majority of patients (90%) remained on peritoneal dialysis at 3-month follow-up. The average costs of surgical and radiological insertion were noted to be AUD$7788.34 and AUD$1597.35, respectively. Radiological Tenckhoff catheter insertion for peritoneal dialysis appears to be an attractive and cost-effective option given less waiting periods for the procedure, the relatively low cost of insertion and comparable rates of complications. © 2017 The Royal Australian and New Zealand College of Radiologists.

  17. Comparison of air-charged and water-filled urodynamic pressure measurement catheters.

    Science.gov (United States)

    Cooper, M A; Fletter, P C; Zaszczurynski, P J; Damaser, M S

    2011-03-01

    Catheter systems are utilized to measure pressure for diagnosis of voiding dysfunction. In a clinical setting, patient movement and urodynamic pumps introduce hydrostatic and motion artifacts into measurements. Therefore, complete characterization of a catheter system includes its response to artifacts as well its frequency response. The objective of this study was to compare the response of two disposable clinical catheter systems: water-filled and air-charged, to controlled pressure signals to assess their similarities and differences in pressure transduction. We characterized frequency response using a transient step test, which exposed the catheters to a sudden change in pressure; and a sinusoidal frequency sweep test, which exposed the catheters to a sinusoidal pressure wave from 1 to 30 Hz. The response of the catheters to motion artifacts was tested using a vortex and the response to hydrostatic pressure changes was tested by moving the catheter tips to calibrated heights. Water-filled catheters acted as an underdamped system, resonating at 10.13 ± 1.03 Hz and attenuating signals at frequencies higher than 19 Hz. They demonstrated significant motion and hydrostatic artifacts. Air-charged catheters acted as an overdamped system and attenuated signals at frequencies higher than 3.02 ± 0.13 Hz. They demonstrated significantly less motion and hydrostatic artifacts than water-filled catheters. The transient step and frequency sweep tests gave comparable results. Air-charged and water-filled catheters respond to pressure changes in dramatically different ways. Knowledge of the characteristics of the pressure-measuring system is essential to finding the best match for a specific application. Copyright © 2011 Wiley-Liss, Inc.

  18. Reducing unnecessary urinary catheter use and other strategies to prevent catheter-associated urinary tract infection: an integrative review

    Science.gov (United States)

    Meddings, Jennifer; Rogers, Mary A M; Krein, Sarah L; Fakih, Mohamad G; Olmsted, Russell N; Saint, Sanjay

    2014-01-01

    Background Catheter-associated urinary tract infections (CAUTI) are costly, common and often preventable by reducing unnecessary urinary catheter (UC) use. Methods To summarise interventions to reduce UC use and CAUTIs, we updated a prior systematic review (through October 2012), and a meta-analysis regarding interventions prompting UC removal by reminders or stop orders. A narrative review summarises other CAUTI prevention strategies including aseptic insertion, catheter maintenance, antimicrobial UCs, and bladder bundle implementation. Results 30 studies were identified and summarised with interventions to prompt removal of UCs, with potential for inclusion in the meta-analyses. By meta-analysis (11 studies), the rate of CAUTI (episodes per 1000 catheter-days) was reduced by 53% (rate ratio 0.47; 95% CI 0.30 to 0.64, p<0.001) using a reminder or stop order, with five studies also including interventions to decrease initial UC placement. The pooled (nine studies) standardised mean difference (SMD) in catheterisation duration (days) was −1.06 overall (p=0.065) including a statistically significant decrease in stop-order studies (SMD −0.37; p<0.001) but not in reminder studies (SMD, −1.54; p=0.071). No significant harm from catheter removal strategies is supported. Limited research is available regarding the impact of UC insertion and maintenance technique. A recent randomised controlled trial indicates antimicrobial catheters provide no significant benefit in preventing symptomatic CAUTIs. Conclusions UC reminders and stop orders appear to reduce CAUTI rates and should be used to improve patient safety. Several evidence-based guidelines have evaluated CAUTI preventive strategies as well as emerging evidence regarding intervention bundles. Implementation strategies are important because reducing UC use involves changing well-established habits. PMID:24077850

  19. Life prolongation and 5-year survival by intensive irradiation of inoperable lung cancer

    International Nuclear Information System (INIS)

    Eichhorn, H.-J.

    1982-01-01

    The effect of intensive radiotherapy on 1-5 year survival rates of patients with inoperable lung cancer is investigated. Some 123 cases were treated with 200 kV X-rays (> 3500 cGy tumour dose) and 1046 with cobalt-60 ν-rays (> 5000 cGy tumour dose). All patients had inoperable, histologically confirmed tumours, limited to one side of the thorax. Survival rates for 1 year were 22% and 37% respectively; for 3 years 1% and 5%; and for 5 years 0 and 2.5%. In all highly differentiated tumours the authors obtained a 5-year survival with telecobalt therapy of 6.5%, and for all oat-cell cases, 2.5%. By comparing the total result with their own control group of 'untreated', but prognostically more favourable patients (122 thoracotomized cases without resection) the increase of survival rates achieved by Cobalt-60 therapy is convincing (2.5 times for 1 year, 5 times for 2 years). Nevertheless, the very unfavourable prognosis for more than half of the cases justifies trials with systemic therapy. To date chemotherapy does not appear to influence survival times (except for small-cell tumours). Therefore randomized trials with two half-body irradiations (800 cGy each, 'Toronto method') are recommended. (Auth.)

  20. Embolization of brain arteriovenous malformations using tracker catheter

    International Nuclear Information System (INIS)

    Kim, Sun Yong; Son, Mi Young; Jang, Jae Chun; Hwang, Mi Soo; Park, Bok Hwan

    1990-01-01

    With the recent advance in micro catheters, steerable guide wires, balloons, embolic materials and digital subtraction angiography (DSA), as well as technical refinements in endovascular surgery, there has been a revolution in therapeutic strategies for cerebral arteriovenous malformations (AVMs). We have performed super selective angiography and embolization with Tracker micro catheter about 12 cases of brain AVMs for therapeutic and preoperative aims. This micro catheter and guide wire provided high selectivity of feeding artery, greater maneuverability and useful for deliver various embolus materials

  1. Adverse effects associated with ethanol catheter lock solutions: a systematic review.

    Science.gov (United States)

    Mermel, Leonard A; Alang, Neha

    2014-10-01

    Antimicrobial lock therapy has been widely utilized internationally for the prevention and management of intravascular catheter-related bloodstream infections. One of the agents commonly utilized for lock therapy is ethanol. However, a systematic review of adverse events associated with ethanol locks has not been published. PubMed was searched to collect articles published from May 2003 through March 2014. The bibliographies of relevant articles were also reviewed. In vitro studies of the mechanical properties of catheters after ethanol immersion have revealed changes predominantly in polyurethane catheters and to a lesser extent in silicone and Carbothane catheters. An elution of polymers from polyurethane and Carbothane catheters has been observed at the ethanol concentrations used in ethanol lock therapy. Ethanol above a concentration of 28% leads to plasma protein precipitation. Ethanol locks were associated with catheter occlusion in 11 studies and independently increased the risk of thrombosis compared with heparin lock in a randomized trial. Six studies noted abnormalities in catheter integrity, including one case leading to catheter embolization. Of note, five of these studies involved silicone catheters. Ethanol lock use was associated with systemic side effects in 10 studies and possible side effects in one additional study. Four studies noted liver function test abnormalities, predominantly transaminase elevation, related to ethanol lock use. However, a prospective study did not find any difference in the risk of doubling the transaminase level above the normal range during use of ethanol locks compared with not using an ethanol lock. The use of ethanol locks has been associated with structural changes in catheters, as well as the elution of molecules from the catheter polymers. Clinical studies have revealed systemic toxicity, increased catheter occlusion and breaches in catheter integrity. © The Author 2014. Published by Oxford University Press on

  2. Potential In Vivo UVC Disinfection of Catheter Lumens: Estimation of the Doses Received by the Blood Flow Outside the Catheter Tip Hole

    DEFF Research Database (Denmark)

    Bak, Jimmy; Jørgensen, Thomas Martini; Helfmann, Jurgen

    2011-01-01

    hole for administration of drugs, bloods or nutrients into the bloodstream. Even if the UVC light is strongly attenuated during its propagation through the catheter tube a fraction of the UVC launched into the catheter will escape through the exit hole and irradiate the blood. We demonstrate......We have demonstrated that it is possible to launch UVC LED light into bacterial contaminated polymer tubes/catheters and disinfect the intraluminal space of these tubes. This can be achieved by UVC treatment of the catheters on a regular basis. Catheters are in the distal end equipped with an exit...... by calculations that very small effective doses are exposed to the blood (ca 10(-4) J m(-2) ). This dosage level is very low compared with UVC doses reported from other therapeutic applications. The very short residence time of the blood constituents in the irradiated volume in front of the exit hole is the main...

  3. The effect of elastic modulus on ablation catheter contact area.

    Science.gov (United States)

    Camp, Jon J; Linte, Cristian A; Rettmann, Maryam E; Sun, Deyu; Packer, Douglas L; Robb, Richard A; Holmes, David R

    2015-02-21

    Cardiac ablation consists of navigating a catheter into the heart and delivering RF energy to electrically isolate tissue regions that generate or propagate arrhythmia. Besides the challenges of accurate and precise targeting of the arrhythmic sites within the beating heart, limited information is currently available to the cardiologist regarding intricate electrode-tissue contact, which directly impacts the quality of produced lesions. Recent advances in ablation catheter design provide intra-procedural estimates of tissue-catheter contact force, but the most direct indicator of lesion quality for any particular energy level and duration is the tissue-catheter contact area, and that is a function of not only force, but catheter pose and material elasticity as well. In this experiment, we have employed real-time ultrasound (US) imaging to determine the complete interaction between the ablation electrode and tissue to accurately estimate contact, which will help to better understand the effect of catheter pose and position relative to the tissue. By simultaneously recording tracked position, force reading and US image of the ablation catheter, the differing material properties of polyvinyl alcohol cryogel [1] phantoms are shown to produce varying amounts of tissue depression and contact area (implying varying lesion quality) for equivalent force readings. We have shown that the elastic modulus significantly affects the surface-contact area between the catheter and tissue at any level of contact force. Thus we provide evidence that a prescribed level of catheter force may not always provide sufficient contact area to produce an effective ablation lesion in the prescribed ablation time.

  4. Tunnelled haemodialysis catheter and haemodialysis outcomes: a retrospective cohort study in Zagreb, Croatia.

    Science.gov (United States)

    Pašara, Vedran; Maksimović, Bojana; Gunjača, Mihaela; Mihovilović, Karlo; Lončar, Andrea; Kudumija, Boris; Žabić, Igor; Knotek, Mladen

    2016-05-17

    Studies have reported that the tunnelled dialysis catheter (TDC) is associated with inferior haemodialysis (HD) patient survival, in comparison with arteriovenous fistula (AVF). Since many cofactors may also affect survival of HD patients, it is unclear whether the greater risk for survival arises from TDC per se, or from associated conditions. Therefore, the aim of this study was to determine, in a multivariate analysis, the long-term outcome of HD patients, with respect to vascular access (VA). Retrospective cohort study. This retrospective cohort study included all 156 patients with a TDC admitted at University Hospital Merkur, from 2010 to 2012. The control group consisted of 97 patients dialysed via AVF. The groups were matched according to dialysis unit and time of VA placement. The site of choice for the placement of the TDC was the right jugular vein. Kaplan-Meier analysis with log-rank test was used to assess patient survival. Multivariate Cox regression analysis was used to determine independent variables associated with patient survival. Patient survival with respect to VA. The cumulative 1-year survival of patients who were dialysed exclusively via TDC was 86.4% and of those who were dialysed exclusively via AVF, survival was 97.1% (p=0.002). In multivariate Cox regression analysis, male sex and older age were independently negatively associated with the survival of HD patients, while shorter HD vintage before the creation of the observed VA, hypertensive renal disease and glomerulonephritis were positively associated with survival. TDC was an independent risk factor for survival of HD patients (HR 23.0, 95% CI 6.2 to 85.3). TDC may be an independent negative risk factor for HD patient survival. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/

  5. SU-F-T-20: Novel Catheter Lumen Recognition Algorithm for Rapid Digitization

    Energy Technology Data Exchange (ETDEWEB)

    Dise, J; McDonald, D; Ashenafi, M; Peng, J; Mart, C; Koch, N; Vanek, K [Medical University of South Carolina, Charleston, SC (United States)

    2016-06-15

    Purpose: Manual catheter recognition remains a time-consuming aspect of high-dose-rate brachytherapy (HDR) treatment planning. In this work, a novel catheter lumen recognition algorithm was created for accurate and rapid digitization. Methods: MatLab v8.5 was used to create the catheter recognition algorithm. Initially, the algorithm searches the patient CT dataset using an intensity based k-means filter designed to locate catheters. Once the catheters have been located, seed points are manually selected to initialize digitization of each catheter. From each seed point, the algorithm searches locally in order to automatically digitize the remaining catheter. This digitization is accomplished by finding pixels with similar image curvature and divergence parameters compared to the seed pixel. Newly digitized pixels are treated as new seed positions, and hessian image analysis is used to direct the algorithm toward neighboring catheter pixels, and to make the algorithm insensitive to adjacent catheters that are unresolvable on CT, air pockets, and high Z artifacts. The algorithm was tested using 11 HDR treatment plans, including the Syed template, tandem and ovoid applicator, and multi-catheter lung brachytherapy. Digitization error was calculated by comparing manually determined catheter positions to those determined by the algorithm. Results: he digitization error was 0.23 mm ± 0.14 mm axially and 0.62 mm ± 0.13 mm longitudinally at the tip. The time of digitization, following initial seed placement was less than 1 second per catheter. The maximum total time required to digitize all tested applicators was 4 minutes (Syed template with 15 needles). Conclusion: This algorithm successfully digitizes HDR catheters for a variety of applicators with or without CT markers. The minimal axial error demonstrates the accuracy of the algorithm, and its insensitivity to image artifacts and challenging catheter positioning. Future work to automatically place initial seed

  6. SU-F-T-20: Novel Catheter Lumen Recognition Algorithm for Rapid Digitization

    International Nuclear Information System (INIS)

    Dise, J; McDonald, D; Ashenafi, M; Peng, J; Mart, C; Koch, N; Vanek, K

    2016-01-01

    Purpose: Manual catheter recognition remains a time-consuming aspect of high-dose-rate brachytherapy (HDR) treatment planning. In this work, a novel catheter lumen recognition algorithm was created for accurate and rapid digitization. Methods: MatLab v8.5 was used to create the catheter recognition algorithm. Initially, the algorithm searches the patient CT dataset using an intensity based k-means filter designed to locate catheters. Once the catheters have been located, seed points are manually selected to initialize digitization of each catheter. From each seed point, the algorithm searches locally in order to automatically digitize the remaining catheter. This digitization is accomplished by finding pixels with similar image curvature and divergence parameters compared to the seed pixel. Newly digitized pixels are treated as new seed positions, and hessian image analysis is used to direct the algorithm toward neighboring catheter pixels, and to make the algorithm insensitive to adjacent catheters that are unresolvable on CT, air pockets, and high Z artifacts. The algorithm was tested using 11 HDR treatment plans, including the Syed template, tandem and ovoid applicator, and multi-catheter lung brachytherapy. Digitization error was calculated by comparing manually determined catheter positions to those determined by the algorithm. Results: he digitization error was 0.23 mm ± 0.14 mm axially and 0.62 mm ± 0.13 mm longitudinally at the tip. The time of digitization, following initial seed placement was less than 1 second per catheter. The maximum total time required to digitize all tested applicators was 4 minutes (Syed template with 15 needles). Conclusion: This algorithm successfully digitizes HDR catheters for a variety of applicators with or without CT markers. The minimal axial error demonstrates the accuracy of the algorithm, and its insensitivity to image artifacts and challenging catheter positioning. Future work to automatically place initial seed

  7. Progression-free survival: gaining on overall survival as a gold standard and accelerating drug development.

    Science.gov (United States)

    Lebwohl, David; Kay, Andrea; Berg, William; Baladi, Jean Francois; Zheng, Ji

    2009-01-01

    In clinical trials of oncology drugs, overall survival (OS) is a direct measure of clinical efficacy and is considered the gold standard primary efficacy end point. The purpose of this study was to discuss the difficulties in using OS as a primary efficacy end point in the setting of evolving cancer therapies. We suggest that progression-free survival is an appropriate efficacy end point in many types of cancer, specifically those for which OS is expected to be prolonged and for which subsequent treatments are expected to affect OS.

  8. Percutaneous Management of Postoperative Duodenal Stump Leakage with Foley Catheter

    International Nuclear Information System (INIS)

    Oh, Jung Suk; Lee, Hae Giu; Chun, Ho Jong; Choi, Byung Gil; Lee, Sang Hoon; Hahn, Seong Tai; Ohm, Joon Young

    2013-01-01

    Purpose: This study was designed to evaluate retrospectively the safety and efficacy of the percutaneous management of duodenal stump leakage with a Foley catheter after subtotal gastrectomy. Methods: Ten consecutive patients (M:F = 9:1, median age: 64 years) were included in this retrospective study. The duodenal stump leakages were diagnosed in all the patients within a median of 10 days (range, 6–20). At first, the patients underwent percutaneous drainage on the day of or the day after confirmation of the presence of duodenal stump leakage, and then the Foley catheters were replaced at a median of 9 days (range, 6–38) after the percutaneous drainage. Results: Foley catheters were placed successfully in the duodenal lumen of all the patients under a fluoroscopic guide. No complication was observed during and after the procedures in all the patients. All of the patients started a regular diet 1 day after the Foley catheter placement. The patients were discharged at a median of 7 days (range, 5–14) after the Foley catheter placement. The catheters were removed in an outpatient clinic 10–58 days (median, 28) after the Foley catheter placement. Conclusions: Fluoroscopy-guided percutaneous Foley catheter placement may be a safe and effective treatment option for postoperative duodenal stump leakage and may allow for shorter hospital stays, earlier oral intake, and more effective control of leakage sites

  9. Prolongation of segmental and pancreaticoduodenal allografts in the primate with total-lymphoid irradiation and cyclosporine

    Energy Technology Data Exchange (ETDEWEB)

    Du Toit, D.F.; Heydenrych, J.J.; Smit, B.; Louw, G.; Zuurmond, T.; Els, D.; Du Toit, L.B.; Weideman, A.; Davids, H.; van der Merwe, E.

    1987-09-01

    The prolongation of segmental and pancreaticoduodenal allografts (PDA) by total lymphoid irradiation (TLI) and in combination with cyclosporine (CsA) was assessed in a well established total pancreatectomy, diabetic, primate transplantation model. Pancreatic transplantation was performed in 119 pancreatectomized baboons (Papio ursinus). Of a total of 109 allografts performed, 71 were segmental allografts (open duct drainage) and 38 PDA. Of 119 graft recipients, 10 received segmental pancreatic autografts. TLI and CsA administered separately to segmental allograft recipients resulted in modest allograft survival and indefinite graft survival was not observed. 8 of 17 (47%) segmental allograft recipients that received TLI and CsA had graft survival beyond 100 days, indicating highly significant pancreatic allograft survival. All long-term segmental allograft recipients were rendered normoglycemic (plasma glucose less than 8 mmol/L) by this immunosuppressive regimen. In contrast, poor results were observed in PDA recipients treated with TLI and CsA. Mean survival in 18 treated PDA recipients was 23.8 days, 8 survived longer than 20 days (44.4%), and 1 greater than 100 days (5.5%). Despite treatment, early rejection of the duodenum in PDA recipients frequently resulted in necrosis and perforation and contributed to a high morbidity and mortality. This study indicates that, in contrast to the significant prolongation of segmental allografts by TLI and CsA, poor immunosuppression was achieved by this regimen in PDA recipients and was associated with a high morbidity and mortality caused by early rejection of the duodenum.

  10. Prolongation of segmental and pancreaticoduodenal allografts in the primate with total-lymphoid irradiation and cyclosporine

    International Nuclear Information System (INIS)

    Du Toit, D.F.; Heydenrych, J.J.; Smit, B.

    1987-01-01

    The prolongation of segmental and pancreaticoduodenal allografts (PDA) by total lymphoid irradiation (TLI) and in combination with cyclosporine (CsA) was assessed in a well established total pancreatectomy, diabetic, primate transplantation model. Pancreatic transplantation was performed in 119 pancreatectomized baboons (Papio ursinus). Of a total of 109 allografts performed, 71 were segmental allografts (open duct drainage) and 38 PDA. Of 119 graft recipients, 10 received segmental pancreatic autografts. TLI and CsA administered separately to segmental allograft recipients resulted in modest allograft survival and indefinite graft survival was not observed. 8 of 17 (47%) segmental allograft recipients that received TLI and CsA had graft survival beyond 100 days, indicating highly significant pancreatic allograft survival. All long-term segmental allograft recipients were rendered normoglycemic (plasma glucose less than 8 mmol/L) by this immunosuppressive regimen. In contrast, poor results were observed in PDA recipients treated with TLI and CsA. Mean survival in 18 treated PDA recipients was 23.8 days, 8 survived longer than 20 days (44.4%), and 1 greater than 100 days (5.5%). Despite treatment, early rejection of the duodenum in PDA recipients frequently resulted in necrosis and perforation and contributed to a high morbidity and mortality. This study indicates that, in contrast to the significant prolongation of segmental allografts by TLI and CsA, poor immunosuppression was achieved by this regimen in PDA recipients and was associated with a high morbidity and mortality caused by early rejection of the duodenum

  11. Reperfusion injury protection during Basic Life Support improves circulation and survival outcomes in a porcine model of prolonged cardiac arrest.

    Science.gov (United States)

    Debaty, Guillaume; Lurie, Keith; Metzger, Anja; Lick, Michael; Bartos, Jason A; Rees, Jennifer N; McKnite, Scott; Puertas, Laura; Pepe, Paul; Fowler, Raymond; Yannopoulos, Demetris

    2016-08-01

    Ischemic postconditioning (PC) using three intentional pauses at the start of cardiopulmonary resuscitation (CPR) improves outcomes after cardiac arrest in pigs when epinephrine (epi) is used before defibrillation. We hypothesized PC, performed during basic life support (BLS) in the absence of epinephrine, would reduce reperfusion injury and enhance 24h functional recovery. Prospective animal investigation. Animal laboratory Female farm pigs (n=46, 39±1kg). Protocol A: After 12min of ventricular fibrillation (VF), 28 pigs were randomized to four groups: (A) Standard CPR (SCPR), (B) active compression-decompression CPR with an impedance threshold device (ACD-ITD), (C) SCPR+PC (SCPR+PC) and (D) ACD-ITD CPR+PC. Protocol B: After 15min of VF, 18 pigs were randomized to ACD-ITD CPR or ACD-ITD+PC. The BLS duration was 2.75min in Protocol A and 5min in Protocol B. Following BLS, up to three shocks were delivered. Without return of spontaneous circulation (ROSC), CPR was resumed and epi (0.5mg) and defibrillation delivered. The primary end point was survival without major adverse events. Hemodynamic parameters and left ventricular ejection fraction (LVEF) were also measured. Data are presented as mean±SEM. Protocol A: ACD-ITD+PC (group D) improved coronary perfusion pressure after 3min of BLS versus the three other groups (28±6, 35±7, 23±5 and 47±7 for groups A, B, C, D respectively, p=0.05). There were no significant differences in 24h survival between groups. LVEF 4h post ROSC was significantly higher with ACD-ITD+PC vs ACD-ITD alone (52.5±3% vs. 37.5±6.6%, p=0.045). Survival rates were significantly higher with ACD-ITD+PC vs. ACD-ITD alone (p=0.027). BLS using ACD-ITD+PC reduced post resuscitation cardiac dysfunction and improved functional recovery after prolonged untreated VF in pigs. 12-11. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  12. Serratia marcescens bacteraemia outbreak in haemodialysis patients with tunnelled catheters due to colonisation of antiseptic solution. Experience at 4 hospitals.

    Science.gov (United States)

    Merino, José L; Bouarich, Hanane; Pita, Mª José; Martínez, Patricia; Bueno, Blanca; Caldés, Silvia; Corchete, Elena; Jaldo, Mª Teresa; Espejo, Beatriz; Paraíso, Vicente

    %) colonised by S. marcescens. Given the routine application of this antiseptic in handling catheters at these units, this was considered the source of contagion and new cases were not observed after the removal of the batches. The presence of bacteraemia due to unconventional germs should alert us to a potential outbreak. The application of a solution contaminated by S. marcescens in haemodialysis catheters was the source of bacteraemia. The intravenous antibiotic treatment and the catheter lock solution allowed an excellent survival of patients and catheters. Copyright © 2016 Sociedad Española de Nefrología. Published by Elsevier España, S.L.U. All rights reserved.

  13. Intravascular catheter-related infection – current concepts

    African Journals Online (AJOL)

    2006-08-28

    Aug 28, 2006 ... prevented. ... blood from both the catheter and a peripheral site, may ... Given the important role of cutaneous microflora in the ... valvular heart disease (especially prosthetic valves) and ... be explained by high arterial flow around the catheter, ... vena cava or right atrium via the cephalic and basilar veins of ...

  14. A COMPARATIVE ANALYSIS OF PERCUTANEOUS AND OPEN SURGICAL TECHNIQUESFOR PERITONEAL CATHETER PLACEMENT.

    LENUS (Irish Health Repository)

    Medani, Samar

    2012-05-01

    BACKGROUND: Peritoneal dialysis (PD) is the preferred available option of renal replacement therapy for a significant number of end-stage kidney disease patients. A major limiting factor to the successful continuation of PD is the long-term viability of the PD catheter (PDC). Bedside percutaneous placement of the PDC is not commonly practiced despite published data encouraging use of this technique. Its advantages include faster recovery and avoidance of general anesthesia.♢ METHODS: We carried out a retrospective analysis of the outcomes of 313 PDC insertions at our center, comparing all percutaneous PDC insertions between July 1998 and April 2010 (group P, n = 151) with all surgical PDC insertions between January 2003 and April 2010 (group S, n = 162).♢ RESULTS: Compared with group P patients, significantly more group S patients had undergone previous abdominal surgery or PDC insertion (41.8% vs 9.3% and 33.3% vs 3.3% respectively, p = 0.00). More exit-site leaks occurred in group P than in group S (20.5% vs 6.8%, p = 0.002). The overall incidence of peritonitis was higher in group S than in group P (1 episode in 19 catheter-months vs 1 episode in 26 catheter-months, p = 0.017), but the groups showed no significant difference in the peritonitis rate within 1 month of catheter insertion (5% in group P vs 7.4% in group S, p =0.4) or in poor initial drainage or secondary drainage failure (9.9% vs 11.7%, p = 0.1, and 7.9% vs 12.3%, p = 0.38, for groups P and S respectively). Technical survival at 3 months was significantly better for group P than for group S (86.6% vs 77%, p = 0.037); at 12 months, it was 77.7% and 68.7% respectively (p = 0.126). No life-threatening complications attributable to the insertion of the PDC occurred in either group.♢ CONCLUSIONS: Our analysis demonstrates further encouraging outcomes of percutaneous PDC placement compared with open surgical placement. However, the members of the percutaneous insertion group were primarily a

  15. Tunnel unroofing effectiveness in chronic peritoneal catheter infection

    Directory of Open Access Journals (Sweden)

    Lorena Carranza

    2017-04-01

    Full Text Available Introduction: Chronic catheter infection usually involves external Dacron cuff colonization, without its removal, antibiotic treatment proved ineffective. Catheter unroofing technique has been described as an alternative to peritoneal catheter removal. Material and methods: We analyzed the data from 13 patients retrospectively. Evolution after unroofing was evaluated, considering as treatment failure the appearance of new infection in the hole, tunnel or peritonitis associated to the same germ. Results: Between 1997-2014 years, unroofing was performed on 13 patients. Mean age-rate: 46.2 (IC 95%: 35.9 years – 56.5 years male sex 9, 69.23%. Germs: staphylococcus 7, pseudomona 2, polymicrobial 1, negative culture 3. Nine patiens healed: 69.2%; there was no statistical association among sex, age, microbiological result, previous hemodialysis use, type of catheter, surgical technique or with the surgeon who performed the procedure (p≥ 0.05. Discussion: Catheter removal implies transient transference to hemodialysis and new replacement surgery, although there is few experience with this technique, it could be an acceptable alternative, enabling a group of patients to continue with PD treatment. Conclusion: Unroofing technique proved to be beneficial in 69.2% of the cases (9 patients independently of the type of germ present, representing an acceptable treatment which avoids catheter removal, enabling the procedure to continue, and decreasing the need to employ more aggressive therapies.

  16. Balloon catheter dilatation in esophageal achalasia: long term follow-up

    Energy Technology Data Exchange (ETDEWEB)

    Shin, Cheol Yong; Park, Hyun Mee; Kim, So Eun; Lee, Shin Hyung; Kim, Seung Hyeon; Lee, Chang Joon [National Medical Center, Seoul (Korea, Republic of)

    1994-12-15

    To evaluate the clinical efficacy of balloon catheter dilatation in the treatment of esophageal achalasia. Seven patients(three males and four females) with esopha-geal achalasia were treated with balloon catheter dilatation. Balloon catheters of variable sizes were used depending on patient's conditions. The patients were followed up over a period of 12-39 months. Balloon catheter dilatation in esophageal achalasia was successful in all patients without esophageal perforation. All patients were relieved from dysphagia. Recurrence was not found in 5 patients on long term follow-up study, but was seen in 2 patients after 18 and 21 months, respectively. Balloon catheter dilatation was a safe and effective method in the treatment of esophageal achalasia with low recurrence rate of 29% on follow-up study.

  17. Balloon catheter dilatation in esophageal achalasia: long term follow-up

    International Nuclear Information System (INIS)

    Shin, Cheol Yong; Park, Hyun Mee; Kim, So Eun; Lee, Shin Hyung; Kim, Seung Hyeon; Lee, Chang Joon

    1994-01-01

    To evaluate the clinical efficacy of balloon catheter dilatation in the treatment of esophageal achalasia. Seven patients(three males and four females) with esopha-geal achalasia were treated with balloon catheter dilatation. Balloon catheters of variable sizes were used depending on patient's conditions. The patients were followed up over a period of 12-39 months. Balloon catheter dilatation in esophageal achalasia was successful in all patients without esophageal perforation. All patients were relieved from dysphagia. Recurrence was not found in 5 patients on long term follow-up study, but was seen in 2 patients after 18 and 21 months, respectively. Balloon catheter dilatation was a safe and effective method in the treatment of esophageal achalasia with low recurrence rate of 29% on follow-up study

  18. Innovating urinary catheter design: An introduction to the engineering challenge.

    Science.gov (United States)

    Murphy, Cathy

    2018-05-01

    Every day, people around the world rely on intermittent and indwelling urinary catheters to manage bladder dysfunction, but the potential or actual harm caused by these devices is well-recognised. Current catheter designs can cause urinary tract infection and septicaemia, bladder and urethral trauma and indwelling devices frequently become blocked. Furthermore, the devices can severely disrupt users' lives, limiting their daily activities and can be costly to manage for healthcare providers. Despite this, little significant design innovation has taken place in the last 80 years. In this article current catheter designs and their limitations are reviewed, common catheter-associated problems are outlined and areas of design ripe for improvement proposed. The potential to relieve the individual and economic burden of catheter use is high.

  19. The dialysis catheter and infectious peritonitis in intermittent peritoneal dialysis

    DEFF Research Database (Denmark)

    Kolmos, Hans Jørn; Hemmeløff Andersen, Karl Erik; Hansen, Lise

    1984-01-01

    118 episodes of infectious peritonitis registered among 156 patients treated with intermittent peritoneal dialysis over a 5-yr period were analysed with special reference to potential routes of infection associated with the dialysis catheter. Peritonitis was randomly distributed among the patients......, and the change of keeping free of peritonitis declined exponentially with time. The main factor determining the individual number of episodes was the total space of time, in which a patient had been wearing a dialysis catheter, whereas the number of catheter disconnections played no significant role. A relative...... preponderance of cases due to Enterobacteriaceae was noted within the first week after catheter implantation. In contrast with this, peritonitis with skin microorganisms was not associated with the implantation of catheters....

  20. Catheter fracture of intravenous ports and its management.

    Science.gov (United States)

    Wu, Ching-Yang; Fu, Jui-Ying; Feng, Po-Hao; Kao, Tsung-Chi; Yu, Sheng-Yueh; Li, Hao-Jui; Ko, Po-Jen; Hsieh, Hung-Chang

    2011-11-01

    Intravenous ports are widely used for oncology patients. However, catheter fractures may lead to the need for re-intervention. We aimed to identify the risk factors associated with catheter fractures. Between January 1 and December 31, 2006, we retrospectively reviewed the clinical data and plain chest films of 1,505 patients implanted with an intravenous port at Chang Gung Memorial Hospital. Different vascular sites were compared using the chi-square or Fisher's exact test for categorical variables, and the t test was used for continuous variables with normal distribution; P port type Arrow French (Fr.) 8.1 (P port and catheter removal is recommended. Female gender, intravenous port implantation via the subclavian route, and the Arrow Fr. 8.1 port were found to be risk factors. Patients with these risk factors should be monitored closely to avoid catheter fractures.

  1. An experimental study about efficacy of the drain catheters

    Energy Technology Data Exchange (ETDEWEB)

    Ahn, Bum Gyu; Nho, Joon Young; Woo, Hyo Cheol; Hwang, Woo Cheol; Park, Choong Ki; Yoon, Jong Sup [Hallym University College of Medicine, Seoul (Korea, Republic of)

    1993-09-15

    Although percutaneous abscess drainage has become and accepted alternative from of therapy for selected patients with abscess, it is well known that there are several factors in the failure of adequate drainage such as pre- and post-procedural management, technique itself, various features of abscess, and selection and application of catheters. Among these factors, we made an experiment about drainage efficacy of commonly used various catheters with different viscosities of water-glycerin solution under the two different pressure gradients. The experimental values of flow rate were very lower than the calculated values. An efficacy of experimental value was 4-14%. Because the inner diameter of fittings and stopcocks was usually smaller than the inner diameter of catheters, these factors also affected the drain efficacy. Finally, we thought that it will be very helpful to the treatment of patient as well as to study about the catheter drainage, if the drain efficacy of individual catheters has been notified.

  2. Vessel bifurcation localization based on intraoperative three-dimensional ultrasound and catheter path for image-guided catheter intervention of oral cancers.

    Science.gov (United States)

    Luan, Kuan; Ohya, Takashi; Liao, Hongen; Kobayashi, Etsuko; Sakuma, Ichiro

    2013-03-01

    We present a method to localize intraoperative target vessel bifurcations under bones for ultrasound (US) image-guided catheter interventions. A catheter path is recorded to acquire skeletons for the target vessel bifurcations that cannot be imaged by intraoperative US. The catheter path is combined with the centerlines of the three-dimensional (3D) US image to construct a preliminary skeleton. Based on the preliminary skeleton, the orientations of target vessels are determined by registration with the preoperative image and the bifurcations were localized by computing the vessel length. An accurate intraoperative vessel skeleton is obtained for correcting the preoperative image to compensate for vessel deformation. A reality check of the proposed method was performed in a phantom experiment. Reasonable results were obtained. The in vivo experiment verified the clinical workflow of the proposed method in an in vivo environment. The accuracy of the centerline length of the vessel for localizing the target artery bifurcation was 2.4mm. These results suggest that the proposed method can allow the catheter tip to stop at the target artery bifurcations and enter into the target arteries. This method can be applied for virtual reality-enhanced image-guided catheter intervention of oral cancers. Copyright © 2013 Elsevier Ltd. All rights reserved.

  3. An inducer of VGF protects cells against ER stress-induced cell death and prolongs survival in the mutant SOD1 animal models of familial ALS.

    Directory of Open Access Journals (Sweden)

    Masamitsu Shimazawa

    2010-12-01

    Full Text Available Amyotrophic lateral sclerosis (ALS is the most frequent adult-onset motor neuron disease, and recent evidence has suggested that endoplasmic reticulum (ER stress signaling is involved in the pathogenesis of ALS. Here we identified a small molecule, SUN N8075, which has a marked protective effect on ER stress-induced cell death, in an in vitro cell-based screening, and its protective mechanism was mediated by an induction of VGF nerve growth factor inducible (VGF: VGF knockdown with siRNA completely abolished the protective effect of SUN N8075 against ER-induced cell death, and overexpression of VGF inhibited ER-stress-induced cell death. VGF level was lower in the spinal cords of sporadic ALS patients than in the control patients. Furthermore, SUN N8075 slowed disease progression and prolonged survival in mutant SOD1 transgenic mouse and rat models of ALS, preventing the decrease of VGF expression in the spinal cords of ALS mice. These data suggest that VGF plays a critical role in motor neuron survival and may be a potential new therapeutic target for ALS, and SUN N8075 may become a potential therapeutic candidate for treatment of ALS.

  4. Control of intravascular catheters using an array of active steering coils.

    Science.gov (United States)

    Gudino, N; Heilman, J A; Derakhshan, J J; Sunshine, J L; Duerk, J L; Griswold, M A

    2011-07-01

    To extend the concept of deflecting the tip of a catheter with the magnetic force created in an MRI system through the use of an array of independently controllable steering coils located in the catheter tip, and to present methods for visualization of the catheter and/or surrounding areas while the catheter is deflected. An array of steering coils made of 42-gauge wire was built over a 2.5 Fr (0.83 mm) fiber braided microcatheter. Two of the coils were 70 turn axial coils separated by 1 cm, and the third was a 15-turn square side coil that was 2 x 4 mm2. Each coil was driven independently by a pulse width modulation (PWM) current source controlled by a microprocessor that received commands from a MATLAB routine that dynamically set current amplitude and direction for each coil. The catheter was immersed in a water phantom containing 1% Gd-DTPA that was placed at the isocenter of a 1.5 T MRI scanner. Deflections of the catheter tip were measured from image-based data obtained with a real-time radio frequency (RF) spoiled gradient echo sequence (GRE). The small local magnetic fields generated by the steering coils were exploited to generate a hyperintense signal at the catheter tip by using a modified GRE sequence that did not include slice-select rewinding gradients. Imaging and excitation modes were implemented by synchronizing the excitation of the steering coil array with the scanner by ensuring that no current was driven through the coils during the data acquisition window; this allowed visualization of the surrounding tissue while not affecting the desired catheter position. Deflections as large as 2.5 cm were measured when exciting the steering coils sequentially with a 100 mA maximum current per coil. When exciting a single axial coil, the deflection was half this value with 30% higher current. A hyperintense catheter tip useful for catheter tracking was obtained by imaging with the modified GRE sequence. Clear visualization of the areas surrounding the

  5. Fecal containment in bedridden patients: economic impact of 2 commercial bowel catheter systems.

    Science.gov (United States)

    Kowal-Vem, Areta; Poulakidas, Stathis; Barnett, Barbara; Conway, Deborah; Culver, Daniel; Ferrari, Michelle; Potenza, Bruce; Koenig, Michael; Mah, John; Majewski, Mary; Morris, Linda; Powers, Jan; Stokes, Elizabeth; Tan, Michael; Salstrom, Sara-Jane; Zaletel, Cindy; Ambutas, Shirley; Casey, Kathleen; Stein, Jayne; DeSane, Mary; Berry, Kathy; Konz, Elizabeth C; Riemer, Michael R; Cullum, Malford E

    2009-05-01

    Fecal contamination is a major challenge in patients in acute/critical care settings that is associated with increased cost of care and supplies and with development of pressure ulcers, incontinence dermatitis, skin and soft tissue infections, and urinary tract infections. To assess the economic impact of fecal containment in bedridden patients using 2 different indwelling bowel catheters and to compare infection rates between groups. A multicenter, observational study was done at 12 US sites (7 that use catheter A, 5 that use catheter B). Patients were followed from insertion of an indwelling bowel catheter system until the patient left the acute/critical care unit or until 29 days after enrollment, whichever came first. Demographic data, frequency of bedding/dressing changes, incidence of infection, and Braden scores (risk of pressure ulcers) were recorded. The study included 146 bedridden patients (76 with catheter A, 70 with catheter B) who had similar Braden scores at enrollment. The rate of bedding/dressing changes per day differed significantly between groups (1.20 for catheter A vs 1.71 for catheter B; P = .004). According to a formula that accounted for personnel resources and laundry cycle costs, catheter A cost $13.94 less per patient per day to use than did catheter B. Catheter A was less likely than was catheter B to be removed during the observational period (P = .03). Observed infection rates were low. Catheter A may be more cost-effective than catheter B because it requires fewer unscheduled linen changes per patient day.

  6. A pilot study to assess adductor canal catheter tip migration in a cadaver model.

    Science.gov (United States)

    Leng, Jody C; Harrison, T Kyle; Miller, Brett; Howard, Steven K; Conroy, Myles; Udani, Ankeet; Shum, Cynthia; Mariano, Edward R

    2015-04-01

    An adductor canal catheter may facilitate early ambulation after total knee arthroplasty, but there is concern over preoperative placement since intraoperative migration of catheters may occur from surgical manipulation and result in ineffective analgesia. We hypothesized that catheter type and subcutaneous tunneling may influence tip migration for preoperatively inserted adductor canal catheters. In a male unembalmed human cadaver, 20 catheter insertion trials were divided randomly into one of four groups: flexible epidural catheter either tunneled or not tunneled; or rigid stimulating catheter either tunneled or not tunneled. Intraoperative patient manipulation was simulated by five range-of-motion exercises of the knee. Distance and length measurements were performed by a blinded regional anesthesiologist. Changes in catheter tip to nerve distance (p = 0.225) and length of catheter within the adductor canal (p = 0.467) were not different between the four groups. Two of five non-tunneled stimulating catheters (40 %) were dislodged compared to 0/5 in all other groups (p = 0.187). A cadaver model may be useful for assessing migration of regional anesthesia catheters; catheter type and subcutaneous tunneling may not affect migration of adductor canal catheters based on this preliminary study. However, future studies involving a larger sample size, actual patients, and other catheter types are warranted.

  7. Percutaneous catheter drainage of intrapulmonary fluid collection

    International Nuclear Information System (INIS)

    Park, E. D.; Kim, H. J.; Choi, P. Y.; Jung, S. H.

    1994-01-01

    With the success of percutaneous abdominal abscess drainage, attention is now being focused on the use of similar techniques in the thorax. We studied to evaluate the effect of percutaneous drainage in parenchymal fluid collections in the lungs. We performed percutaneous drainage of abscesses and other parenchymal fluid collections of the lungs in 15 patients. All of the procedures were performed under the fluoroscopic guidance with an 18-gauge Seldinger needle and coaxial technique with a 8-10F drainage catheter. Among 10 patients with lung abscess, 8 patients improved by percutaneous catheter drainage. In one patient, drainage was failed by the accidental withdrawal of the catheter before complete drainage. One patient died of sepsis 5 hours after the procedure. Among three patients with complicated bulla, successful drainage was done in two patients, but in the remaining patient, the procedure was failed. In one patient with intrapulmonary bronchogenic cyst, the drainage was not successful due to the thick internal contents. In one patient with traumatic hematoma, after the drainage of old blood clots, the signs of infection disappeared. Overally, of 14 patients excluding one who died, 11 patients improved with percutaneous catheter drainage and three patients did not. There were no major complications during and after the procedure. We conclude that percutaneous catheter drainage is effective and safe procedure for the treatment of parenchymal fluid collections of the lung in patients unresponsive to the medical treatment

  8. Percutaneous catheter drainage of intrapulmonary fluid collection

    Energy Technology Data Exchange (ETDEWEB)

    Park, E. D.; Kim, H. J.; Choi, P. Y.; Jung, S. H. [Gyeongsang National University Hospital, Chinju (Korea, Republic of)

    1994-01-15

    With the success of percutaneous abdominal abscess drainage, attention is now being focused on the use of similar techniques in the thorax. We studied to evaluate the effect of percutaneous drainage in parenchymal fluid collections in the lungs. We performed percutaneous drainage of abscesses and other parenchymal fluid collections of the lungs in 15 patients. All of the procedures were performed under the fluoroscopic guidance with an 18-gauge Seldinger needle and coaxial technique with a 8-10F drainage catheter. Among 10 patients with lung abscess, 8 patients improved by percutaneous catheter drainage. In one patient, drainage was failed by the accidental withdrawal of the catheter before complete drainage. One patient died of sepsis 5 hours after the procedure. Among three patients with complicated bulla, successful drainage was done in two patients, but in the remaining patient, the procedure was failed. In one patient with intrapulmonary bronchogenic cyst, the drainage was not successful due to the thick internal contents. In one patient with traumatic hematoma, after the drainage of old blood clots, the signs of infection disappeared. Overally, of 14 patients excluding one who died, 11 patients improved with percutaneous catheter drainage and three patients did not. There were no major complications during and after the procedure. We conclude that percutaneous catheter drainage is effective and safe procedure for the treatment of parenchymal fluid collections of the lung in patients unresponsive to the medical treatment.

  9. Safety and efficacy of distal perfusion catheterization to prevent limb ischemia after common femoral artery cannulation for extracorporeal membrane oxygenation

    Energy Technology Data Exchange (ETDEWEB)

    Jeon, Chang Ho; Seong, Nak Jong; Yoon, Chang Jin [Dept. of Radiology, Seoul National University Bundang Hospital, Seongnam (Korea, Republic of)

    2016-06-15

    The extracorporeal membrane oxygenation (ECMO) cannula has the potential for obstructing flow to the lower limb, thus causing severe ischemia and possible limb loss. We evaluated the safety and clinical efficacy of percutaneous distal perfusion catheterization in preventing limb ischemia. Between March 2013 and February 2015, 28 patients with distal perfusion catheterization after ECMO were included in this retrospective study. The technical success was evaluated by Doppler ultrasound at the popliteal level after saline injection via distal perfusion catheter. Clinical success was assessed when at least one of the following conditions was met: restoration of continuous peripheral limb oximetry value or presence of distal arterial pulse on Doppler ultrasound evaluation or resolution of early ischemic sign after connecting the catheter with ECMO. Twenty-six patients with early ischemia were successfully cannulated with a distal perfusion catheter (92.8%). Clinical success was achieved in 12/28 (42.8%) patients; 8/10 (80.0%) patients with survival duration exceeding 7 days and 4/18 (22.2%) patients with survival duration less than 7 days, respectively. A percutaneous distal perfusion catheter placement was a feasible tool with safety and efficacy in preventing lower limb ischemia for patients with prolonged common femoral arterial cannulation for ECMO.

  10. Safety and efficacy of distal perfusion catheterization to prevent limb ischemia after common femoral artery cannulation for extracorporeal membrane oxygenation

    International Nuclear Information System (INIS)

    Jeon, Chang Ho; Seong, Nak Jong; Yoon, Chang Jin

    2016-01-01

    The extracorporeal membrane oxygenation (ECMO) cannula has the potential for obstructing flow to the lower limb, thus causing severe ischemia and possible limb loss. We evaluated the safety and clinical efficacy of percutaneous distal perfusion catheterization in preventing limb ischemia. Between March 2013 and February 2015, 28 patients with distal perfusion catheterization after ECMO were included in this retrospective study. The technical success was evaluated by Doppler ultrasound at the popliteal level after saline injection via distal perfusion catheter. Clinical success was assessed when at least one of the following conditions was met: restoration of continuous peripheral limb oximetry value or presence of distal arterial pulse on Doppler ultrasound evaluation or resolution of early ischemic sign after connecting the catheter with ECMO. Twenty-six patients with early ischemia were successfully cannulated with a distal perfusion catheter (92.8%). Clinical success was achieved in 12/28 (42.8%) patients; 8/10 (80.0%) patients with survival duration exceeding 7 days and 4/18 (22.2%) patients with survival duration less than 7 days, respectively. A percutaneous distal perfusion catheter placement was a feasible tool with safety and efficacy in preventing lower limb ischemia for patients with prolonged common femoral arterial cannulation for ECMO

  11. The role of C/EBPa in PD-1+ CD4+ T cells & modulation of RNR activity prolongs survival of mice with AML

    DEFF Research Database (Denmark)

    Norrie, Ida Christine

    of age-dependent PD-1+ CD4+ T cells was therefore investigated as well as its importance for development of PD-1+ CD4+ T cells during leukemic development. My results showed that loss of C/EBPα expression in the lymphoid compartment led to an increased amount of aged PD-1+ CD4+ T cells, but not of young...... PD-1+ CD4+ T cells, suggesting that C/EBPα repress the accumulation of these cells in old mice. Furthermore, C/EBPα-deficiency in the lymphoid compartment had no effect on leukemic development and did not affect the accumulation of PD-1+ CD4+ T cells during development of leukemia. M data indicates......The Ph.D. thesis comprises two projects: (1) C/EBPα is dispensable for the ontogeny of PD1+ CD4+ memory T cells, but restricts their expansion in an age-dependent manner. (2) Modulation of RNR activity prolongs survival of mice with AML. Immunosenescence is a condition of the immune system...

  12. Dialysis catheter-related superior vena cava syndrome with patent vena cava: Long term efficacy of unilateral viatorr stent-graft avoiding catheter manipulation

    Energy Technology Data Exchange (ETDEWEB)

    Quaretti, Pietro; Galli, Franco; Maramarco, Lorenzo Paplo; Corti, Riccardo; Leati, Giovanni; Fiorina, Ilaria; Maestri, Marcello [IRCCS Policlinico San Matteo Foundation, Pavia (Italy)

    2014-06-15

    Central venous catheters are the most frequent causes of benign central vein stenosis. We report the case of a 79-year-old woman on hemodialysis through a twin catheter in the right internal jugular vein, presenting with superior vena cava (SVC) syndrome with patent SVC. The clinically driven endovascular therapy was conducted to treat the venous syndrome with a unilateral left brachiocephalic stent-graft without manipulation of the well-functioning catheter. The follow-up was uneventful until death 94 months later.

  13. Dialysis catheter-related superior vena cava syndrome with patent vena cava: Long term efficacy of unilateral viatorr stent-graft avoiding catheter manipulation

    International Nuclear Information System (INIS)

    Quaretti, Pietro; Galli, Franco; Maramarco, Lorenzo Paplo; Corti, Riccardo; Leati, Giovanni; Fiorina, Ilaria; Maestri, Marcello

    2014-01-01

    Central venous catheters are the most frequent causes of benign central vein stenosis. We report the case of a 79-year-old woman on hemodialysis through a twin catheter in the right internal jugular vein, presenting with superior vena cava (SVC) syndrome with patent SVC. The clinically driven endovascular therapy was conducted to treat the venous syndrome with a unilateral left brachiocephalic stent-graft without manipulation of the well-functioning catheter. The follow-up was uneventful until death 94 months later.

  14. Multiple Coaxial Catheter System for Reliable Access in Interventional Stroke Therapy

    International Nuclear Information System (INIS)

    Kulcsar, Zsolt; Yilmaz, Hasan; Bonvin, Christophe; Lovblad, Karl O.; Ruefenacht, Daniel A.

    2010-01-01

    In some patients with acute cerebral vessel occlusion, navigating mechanical thrombectomy systems is difficult due to tortuous anatomy of the aortic arch, carotid arteries, or vertebral arteries. Our purpose was to describe a multiple coaxial catheter system used for mechanical revascularization that helps navigation and manipulations in tortuous vessels. A triple or quadruple coaxial catheter system was built in 28 consecutive cases presenting with acute ischemic stroke. All cases were treated by mechanical thrombectomy with the Penumbra System. In cases of unsuccessful thrombo-aspiration, additional thrombolysis or angioplasty with stent placement was used for improving recanalization. The catheter system consisted of an outermost 8-Fr and an intermediate 6-Fr guiding catheter, containing the inner Penumbra reperfusion catheters. The largest, 4.1-Fr, reperfusion catheter was navigated over a Prowler Select Plus microcatheter. The catheter system provided access to reach the cerebral lesions and provided stability for the mechanically demanding manipulations of thromboaspiration and stent navigation in all cases. Apart from their mechanical role, the specific parts of the system could also provide access to different types of interventions, like carotid stenting through the 8-Fr guiding catheter and intracranial stenting and thrombolysis through the Prowler Select Plus microcatheter. In this series, there were no complications related to the catheter system. In conclusion, building up a triple or quadruple coaxial system proved to be safe and efficient in our experience for the mechanical thrombectomy treatment of acute ischemic stroke.

  15. Septic Thrombophlebitis of the Cephalic Vein Caused by a Peripherally Inserted Venous Catheter

    Directory of Open Access Journals (Sweden)

    M Mirmohammadsadeghi

    2005-07-01

    Full Text Available Septic thrombophlebitis of a vein is a rare but life-threatening complication of an intravascular (IV catheter placed percutaneously in the veins. Most published clinical experiences with IV catheters, mainly in the outpatient settings, have reported very low rates of catheter-related bloodstream infection compared to rates with central venous catheters placed in a subclavian or internal jugular vein. Most of the complications reported with IV catheters have been non-infectious, particularly sterile phlebitis or thrombosis. We report a case of cephalic vein suppurative thrombophlebitis from an intravascular catheter and offer guidelines for diagnosis and management of this complication. Key words: Septic thrombophlebitis, Intravascular catheter, Suppurative thrombophlebitis

  16. Radiologic interventional retrieval of retained central venous catheter fragment in prematurity: case report

    International Nuclear Information System (INIS)

    Park, Jee Won; Jo, Jung Hyun; Park, Byeong Ho

    2007-01-01

    The fracture of a central venous catheter is a rare but potentially serious complication. Moreover, removal of the broken catheter pieces is considerably challenging, especially for premature infants. We report 3 case studies of the percutaneous transcatheter retrieval of broken catheter parts in 3 premature infants. We confirmed the location of the catheter fragments via a DSA venogram with diluted contrast media. Using the minimum amount of contrast, and extreme caution, we made certain no contrast-induced nephrotoxicity of air embolism occurred during catheter manipulation. In addition, when the broken fragment was curled or attached to the cardiac wall, we used a hook-shaped catheter to facilitate the capturing of the catheter with a loopsnare. This report demonstrates the feasibility of removing a retained catheter fragment in a premature infant using a percutaneous transcatheter approach

  17. Foley Catheter versus Vaginal Misoprostol for Labour Induction

    Directory of Open Access Journals (Sweden)

    Nasreen Noor

    2015-01-01

    Full Text Available Objectives. To compare the efficacy and safety of intravaginal misoprostol with transcervical Foley catheter for labour induction. Material and Methods. One hundred and four women with term gestation, with Bishop score < 4, and with various indications for labour induction were randomly divided into two groups. In Group I, 25 μg of misoprostol tablet was placed intravaginally, 4 hourly up to maximum 6 doses. In Group II, Foley catheter 16F was placed through the internal os of the cervix under aseptic condition and then inflated with 50 cc of sterile saline. Statistical analysis was done using SPSS software. Results. The induction to delivery interval was 14.03 ± 7.61 hours versus 18.40 ± 8.02 hours (p<0.01. The rate of vaginal delivery was 76.7% versus 56.8% in misoprostol and transcervical Foley catheter group, respectively. Uterine hyperstimulation was more common with misoprostol. Neonatal outcome was similar in both the groups. Conclusion. Intravaginal misoprostol is associated with a shorter induction to delivery interval as compared to Foley’s catheter and it increases the rate of vaginal delivery in cases of unripe cervix at term. Transcervical Foley catheter is associated with a lower incidence of uterine hyperstimulation during labour.

  18. The use of peridural catheter in the treatment of chronic malignant pain in the abdomen: Case report (peridural catheter in the treatment chronic pain

    Directory of Open Access Journals (Sweden)

    Palibrk Ivan

    2017-01-01

    Full Text Available Introduction: Chronic pain in the abdomen occurs as a consequence of malignancy in these parts of the body, surgical, of radiological and chemotherapy treatments. It may also be as a result of relapse of the basic process. Non-invasive therapy of oral and transdermal analgesic was successful for some time, where necessary applies and epidural catheter. Case Report: The patient had a diagnosis of chronic postoperative pain malignant etiology. He is already used transdermal fentanyl and Nonsteroidal Anti-Inflammatory Drugs, but without success (VAS score 8-10. We increased doses of analgesics, but without success. In order of pain therapy, peridural catheter placed in the level L3 - L4. 5 ml of a solution of 8 ml of 0.25% bupivacaine, 2 ml (100 micrograms of fentanyl and 10 ml of saline was administered every 6 hours through epidural catheter. The former chronic non-invasive treatment of pain did not stop. The first three to five days of pain relief was quite satisfactory in this way. Then the pain intensified but the peridural catheter had to be removed due to local infection. New peridural catheter was placed in the level L2 -L3. Then, 5 ml of the solution: of 8 ml 0,25% bupivacaine, 2 ml (100 micrograms of fentanyl and 10 ml of saline is administered through peridural catheter. Peridural catheter was total used for 45 days. We had a need for more and more frequently administering analgesics through a catheter during use. The patient was using transdermal fentanyl and Nonsteroidal Anti-Inflammatory Drugs, all the time. The patient soon died due to progression of the underlying disease. Conclusion: After long-term administration of opioids, it is necessary to change the type and route of administration of the drug to achieve the success of the therapy. In this case it was the use of analgesics and local anesthetics through the peridural catheter.

  19. Hemodialysis Catheter Heat Transfer for Biofilm Prevention and Treatment.

    Science.gov (United States)

    Richardson, Ian P; Sturtevant, Rachael; Heung, Michael; Solomon, Michael J; Younger, John G; VanEpps, J Scott

    2016-01-01

    Central line-associated bloodstream infections (CLABSIs) are not easily treated, and many catheters (e.g., hemodialysis catheters) are not easily replaced. Biofilms (the source of infection) on catheter surfaces are notoriously difficult to eradicate. We have recently demonstrated that modest elevations of temperature lead to increased staphylococcal susceptibility to vancomycin and significantly soften the biofilm matrix. In this study, using a combination of microbiological, computational, and experimental studies, we demonstrate the efficacy, feasibility, and safety of using heat as an adjuvant treatment for infected hemodialysis catheters. Specifically, we show that treating with heat in the presence of antibiotics led to additive killing of Staphylococcus epidermidis with similar trends seen for Staphylococcus aureus and Klebsiella pneumoniae. The magnitude of temperature elevation required is relatively modest (45-50°C) and similar to that used as an adjuvant to traditional cancer therapy. Using a custom-designed benchtop model of a hemodialysis catheter, positioned with tip in the human vena cava as well as computational fluid dynamic simulations, we demonstrate that these temperature elevations are likely achievable in situ with minimal increased in overall blood temperature.

  20. Infection and natural history of emergency department-placed central venous catheters.

    Science.gov (United States)

    LeMaster, Christopher H; Schuur, Jeremiah D; Pandya, Darshan; Pallin, Daniel J; Silvia, Jennifer; Yokoe, Deborah; Agrawal, Ashish; Hou, Peter C

    2010-11-01

    Central line-associated bloodstream infection (CLABSI, hereafter referred to in this paper as "bloodstream infection") is a leading cause of hospital-acquired infection. To our knowledge, there are no previously published studies designed to determine the rate of bloodstream infection among central venous catheters placed in the emergency department (ED). We design a retrospective chart review methodology to determine bloodstream infection and duration of catheterization for central venous catheters placed in the ED. Using hospital infection control, administrative, and ED billing databases, we identified patients with central venous catheters placed in the ED between January 1, 2007, and December 31, 2008, at one academic, urban ED with an annual census of 57,000. We performed a structured, explicit chart review to determine duration of catheterization and confirm bloodstream infection. We screened 4,251 charts and identified 656 patients with central venous catheters inserted in the ED, 3,622 catheter-days, and 7 bloodstream infections. The rate of bloodstream infection associated with central venous catheters placed in the ED was 1.93 per 1,000 catheter-days (95% confidence interval 0.50 to 3.36). The mean duration of catheterization was 5.5 days (median 4; range 1 to 29 days). Among infected central venous catheters, the mean duration of catheterization was 8.6 days (median 7; range 2 to 19 days). A total of 667 central venous catheters were placed in the internal jugular (392; 59%), subclavian (145; 22%), and femoral (130; 19%) veins. The sensitivity of using ED procedural billing code for identifying ED-placed central venous catheters among patients subsequently admitted to any ICU was 74.9% (95% confidence interval 71.4% to 78.3%). The rate of ED bloodstream infection at our institution is similar to current rates in ICUs. Central venous catheters placed in the ED remain in admitted patients for a substantial period. Copyright © 2010 American College of

  1. Prostate HDR brachytherapy catheter displacement between planning and treatment delivery

    International Nuclear Information System (INIS)

    Whitaker, May; Hruby, George; Lovett, Aimee; Patanjali, Nitya

    2011-01-01

    Background and purpose: HDR brachytherapy is used as a conformal boost for treating prostate cancer. Given the large doses delivered, it is critical that the volume treated matches that planned. Our outpatient protocol comprises two 9 Gy fractions, two weeks apart. We prospectively assessed catheter displacement between CT planning and treatment delivery. Materials and methods: Three fiducial markers and the catheters were implanted under transrectal ultrasound guidance. Metal marker wires were inserted into 4 reference catheters before CT; marker positions relative to each other and to the marker wires were measured from the CT scout. Measurements were repeated immediately prior to treatment delivery using pelvic X-ray with marker wires in the same reference catheters. Measurements from CT scout and film were compared. For displacements of 5 mm or more, indexer positions were adjusted prior to treatment delivery. Results: Results are based on 48 implants, in 25 patients. Median time from planning CT to treatment delivery was 254 min (range 81–367 min). Median catheter displacement was 7.5 mm (range −2.9–23.9 mm), 67% of implants had displacement of 5 mm or greater. Displacements were predominantly caudal. Conclusions: Catheter displacement can occur in the 1–3 h between the planning CT scan and treatment. It is recommended that departments performing HDR prostate brachytherapy verify catheter positions immediately prior to treatment delivery.

  2. Detection of electrophysiology catheters in noisy fluoroscopy images

    NARCIS (Netherlands)

    Franken, E.M.; Rongen, P.M.J.; Almsick, van M.A.; Haar Romenij, ter B.M.

    2006-01-01

    Cardiac catheter ablation is a minimally invasive medical procedure to treat patients with heart rhythm disorders. It is useful to know the positions of the catheters and electrodes during the intervention, e.g. for the automatization of cardiac mapping. Our goal is therefore to develop a robust

  3. Chitosan-based coatings in the prevention of intravascular catheter-associated infections.

    Science.gov (United States)

    Mendoza, Gracia; Regiel-Futyra, Anna; Tamayo, Alejandra; Monzon, Marta; Irusta, Silvia; de Gregorio, Miguel Angel; Kyzioł, Agnieszka; Arruebo, Manuel

    2018-01-01

    Central venous access devices play an important role in patients with prolonged intravenous administration requirements. In the last years, the coating of these devices with bactericidal compounds has emerged as a potential tool to prevent bacterial colonization. Our study describes the modification of 3D-printed reservoirs and silicone-based catheters, mimicking central venous access devices, through different approaches including their coating with the well known biocompatible and bactericidal polymer chitosan, with the anionic polysaccharide alginate; also, plasma treated surfaces were included in the study to promote polymer adhesion. The evaluation of the antimicrobial action of those surface modifications compared to that exerted by a model antibiotic (ciprofloxacin) adsorbed on the surface of the devices was carried out. Surface characterization was developed by different methodologies and the bactericidal effects of the different coatings were assayed in an in vitro model of Staphylococcus aureus infection. Our results showed a significant reduction in the reservoir roughness (≤73%) after coating though no changes were observed for coated catheters which was also confirmed by scanning electron microscopy, pointing to the importance of the surface device topography for the successful attachment of the coating and for the subsequent development of bactericidal effects. Furthermore, the single presence of chitosan on the reservoirs was enough to fully inhibit bacterial growth exerting the same efficiency as that showed by the model antibiotic. Importantly, chitosan coating showed low cytotoxicity against human keratinocytes, human lung adenocarcinoma epithelial cells, and murine colon carcinoma cells displaying viability percentages in the range of the control samples (>95%). Chitosan-based coatings are proposed as an effective and promising solution in the prevention of microbial infections associated to medical devices.

  4. Development of a force-reflecting robotic platform for cardiac catheter navigation.

    Science.gov (United States)

    Park, Jun Woo; Choi, Jaesoon; Pak, Hui-Nam; Song, Seung Joon; Lee, Jung Chan; Park, Yongdoo; Shin, Seung Min; Sun, Kyung

    2010-11-01

    Electrophysiological catheters are used for both diagnostics and clinical intervention. To facilitate more accurate and precise catheter navigation, robotic cardiac catheter navigation systems have been developed and commercialized. The authors have developed a novel force-reflecting robotic catheter navigation system. The system is a network-based master-slave configuration having a 3-degree of freedom robotic manipulator for operation with a conventional cardiac ablation catheter. The master manipulator implements a haptic user interface device with force feedback using a force or torque signal either measured with a sensor or estimated from the motor current signal in the slave manipulator. The slave manipulator is a robotic motion control platform on which the cardiac ablation catheter is mounted. The catheter motions-forward and backward movements, rolling, and catheter tip bending-are controlled by electromechanical actuators located in the slave manipulator. The control software runs on a real-time operating system-based workstation and implements the master/slave motion synchronization control of the robot system. The master/slave motion synchronization response was assessed with step, sinusoidal, and arbitrarily varying motion commands, and showed satisfactory performance with insignificant steady-state motion error. The current system successfully implemented the motion control function and will undergo safety and performance evaluation by means of animal experiments. Further studies on the force feedback control algorithm and on an active motion catheter with an embedded actuation mechanism are underway. © 2010, Copyright the Authors. Artificial Organs © 2010, International Center for Artificial Organs and Transplantation and Wiley Periodicals, Inc.

  5. Intravascular (catheter) MR imaging

    International Nuclear Information System (INIS)

    Cohen, A.M.; Hurst, G.C.; Katz, D.E.; Dverk, J.L.; Wiesen, E.J.; Czerski, L.W.; Malaya, R.; Bellon, E.M.

    1989-01-01

    Intravascular MR probes allow excellent spatial resolution and have the potential to detect arterial wall microstructure. Ultrasonic intravascular probes suggest that detailed morphologic information can assist clinical decision making. Catheter MR probes of 2--7 mm outside diameter (OD) were built of copper wire, Teflon, and parts from standard commercial catheters. The probes were connected to the surface coil receiver input of our Picker VISTA 2055HP 1.5-T imaging system. The extant (linear) body coil was used for transmit. Phantoms were constructed of coaxial glass MR tubes, filled with doped water. Watanabe rabbit aorta and human autopsy iliac artery specimens were examined within 4 hours of excision or stored by freezing. In vivo iliac arteries in dogs under general anesthesia were imaged, with percutaneous placement of the probe. Results are presented

  6. Performance evaluation of a robot-assisted catheter operating system with haptic feedback.

    Science.gov (United States)

    Song, Yu; Guo, Shuxiang; Yin, Xuanchun; Zhang, Linshuai; Hirata, Hideyuki; Ishihara, Hidenori; Tamiya, Takashi

    2018-06-20

    In this paper, a novel robot-assisted catheter operating system (RCOS) has been proposed as a method to reduce physical stress and X-ray exposure time to physicians during endovascular procedures. The unique design of this system allows the physician to apply conventional bedside catheterization skills (advance, retreat and rotate) to an input catheter, which is placed at the master side to control another patient catheter placed at the slave side. For this purpose, a magnetorheological (MR) fluids-based master haptic interface has been developed to measure the axial and radial motions of an input catheter, as well as to provide the haptic feedback to the physician during the operation. In order to achieve a quick response of the haptic force in the master haptic interface, a hall sensor-based closed-loop control strategy is employed. In slave side, a catheter manipulator is presented to deliver the patient catheter, according to position commands received from the master haptic interface. The contact forces between the patient catheter and blood vessel system can be measured by designed force sensor unit of catheter manipulator. Four levels of haptic force are provided to make the operator aware of the resistance encountered by the patient catheter during the insertion procedure. The catheter manipulator was evaluated for precision positioning. The time lag from the sensed motion to replicated motion is tested. To verify the efficacy of the proposed haptic feedback method, the evaluation experiments in vitro are carried out. The results demonstrate that the proposed system has the ability to enable decreasing the contact forces between the catheter and vasculature.

  7. Catheter Removal versus Retention in the Management of Catheter-Associated Enterococcal Bloodstream Infections

    Directory of Open Access Journals (Sweden)

    Jonas Marschall

    2013-01-01

    Full Text Available BACKGROUND: Enterococci are an important cause of central venous catheter (CVC-associated bloodstream infections (CA-BSI. It is unclear whether CVC removal is necessary to successfully manage enterococcal CA-BSI.

  8. Cost-effectiveness of a central venous catheter care bundle.

    Directory of Open Access Journals (Sweden)

    Kate A Halton

    Full Text Available BACKGROUND: A bundled approach to central venous catheter care is currently being promoted as an effective way of preventing catheter-related bloodstream infection (CR-BSI. Consumables used in the bundled approach are relatively inexpensive which may lead to the conclusion that the bundle is cost-effective. However, this fails to consider the nontrivial costs of the monitoring and education activities required to implement the bundle, or that alternative strategies are available to prevent CR-BSI. We evaluated the cost-effectiveness of a bundle to prevent CR-BSI in Australian intensive care patients. METHODS AND FINDINGS: A Markov decision model was used to evaluate the cost-effectiveness of the bundle relative to remaining with current practice (a non-bundled approach to catheter care and uncoated catheters, or use of antimicrobial catheters. We assumed the bundle reduced relative risk of CR-BSI to 0.34. Given uncertainty about the cost of the bundle, threshold analyses were used to determine the maximum cost at which the bundle remained cost-effective relative to the other approaches to infection control. Sensitivity analyses explored how this threshold alters under different assumptions about the economic value placed on bed-days and health benefits gained by preventing infection. If clinicians are prepared to use antimicrobial catheters, the bundle is cost-effective if national 18-month implementation costs are below $1.1 million. If antimicrobial catheters are not an option the bundle must cost less than $4.3 million. If decision makers are only interested in obtaining cash-savings for the unit, and place no economic value on either the bed-days or the health benefits gained through preventing infection, these cost thresholds are reduced by two-thirds. CONCLUSIONS: A catheter care bundle has the potential to be cost-effective in the Australian intensive care setting. Rather than anticipating cash-savings from this intervention, decision

  9. Temperature-controlled irrigated tip radiofrequency catheter ablation

    DEFF Research Database (Denmark)

    Petersen, H H; Chen, X; Pietersen, Adrian

    1998-01-01

    INTRODUCTION: In patients with ventricular tachycardias due to structural heart disease, catheter ablation cures radiofrequency ablation. Irrigated tip radiofrequency ablation using power control and high infusion rates enlarges lesion......: We conclude that temperature-controlled radiofrequency ablation with irrigated tip catheters using low target temperature and low infusion rate enlarges lesion size without increasing the incidence of cratering and reduces coagulum formation of the tip....

  10. Coexistence of Ureaplasma and chorioamnionitis is associated with prolonged mechanical ventilation.

    Science.gov (United States)

    Jung, Euiseok; Choi, Chang Won; Kim, Su Yeong; Sung, Tae-Jung; Kim, Haeryoung; Park, Kyoung Un; Kim, Han-Suk; Kim, Beyong Il; Choi, Jung-Hwan

    2017-01-01

    Both histologic chorioamnionitis (HCAM) and Ureaplasma infection are considered important contributors to perinatal lung injury. We tested the hypothesis that coexistence of maternal HCAM and perinatal Ureaplasma exposure increases the risk of prolonged mechanical ventilation in extremely low-birthweight (ELBW) infants. A retrospective cohort study was carried out of all ELBW infants born between January 2008 and December 2013 at a single academic center. Placental pathology and gastric fluid Ureaplasma data were available for all infants. Culture and polymerase chain reaction were used to detect Ureaplasma in gastric fluid. Prolonged mechanical ventilation was defined as mechanical ventilation that began within 28 days after birth and continued. Of 111 ELBW infants enrolled, 84 survived beyond 36 weeks of postmenstrual age (PMA) and were included in the analysis. Eighteen infants (21.4%) had both HCAM and Ureaplasma exposure. Seven infants (8.3%) required mechanical ventilation beyond 36 weeks of PMA. Coexistence of HCAM and Ureaplasma in gastric fluid was significantly associated with prolonged mechanical ventilation after adjustment for gestational age, sex, mode of delivery, and use of macrolide antibiotics (OR, 8.7; 95%CI: 1.1-67.2). Coexistence of maternal HCAM and perinatal Ureaplasma exposure significantly increases the risk of prolonged mechanical ventilation in ELBW infants. © 2016 Japan Pediatric Society.

  11. More than just a urinary catheter — Haemorrhage control by using a Foley catheter in a penetrating aortic root injury

    Directory of Open Access Journals (Sweden)

    Adel Elmoghrabi

    2016-08-01

    Full Text Available The prevalence of great vessel injuries in thoracic trauma is reported at 0.3–10%, predominantly due to a penetrating mechanism. Thoracic aortic injuries, more specifically those within proximity of the aortic root are challenging to manage and unceasing bleeding hampers adequate visualisation for performing repair. We report a case of a 31-year-old male that presented to the emergency department 1 h after sustaining a stab wound injury within proximity of the left upper sternal border. Vital signs were stable on presentation. Physical examination revealed a 1.5 cm laceration in the 3rd intercostal space. Chest X-ray revealed a small left pneumothorax, FAST scan was negative, and CT of the chest revealed left sided haemopneumothorax and haemopericardium. The patient was emergently transferred to the operating room where median thoracotomy was performed. A significant amount of bleeding was observed originating from a 1 cm laceration of the aortic root. Bleeding was controlled using a Foley catheter after unsuccessful attempts of digital compression, and the laceration was repaired using pledgeted sutures. Postoperative echocardiography and CT scan of the chest revealed normal cardiac functions with resolution of haemopericardium and haemopneumothorax, and the patient was discharged in a stable condition. High index of suspicion should be maintained for injury to the great vessels in patients with penetrating chest injuries, despite apparent haemodynamic stability. In this case, balloon tamponade using a Foley catheter served as a quick and simple technique that resulted in an almost bloodless field, facilitating adequate visualisation for definitive repair. Although the use of this technique has been previously described, this report serves as a reminder that a Foley catheter can be successfully used for balloon catheter tamponade in injuries to the aortic root. Keywords: Aortic root, Injury, Foley's catheter, Balloon catheter, Aorta

  12. Needle catheter duodenostomy: a technique for duodenal alimentation of birds.

    Science.gov (United States)

    Goring, R L; Goldman, A; Kaufman, K J; Roberts, C; Quesenberry, K E; Kollias, G V

    1986-11-01

    A technique for duodenal alimentation (needle catheter duodenostomy) of birds was developed, using the domestic pigeon (Columba livia) as the experimental model. A needle catheter was inserted into the descending duodenum of 5 pigeons and was secured to the body wall and dorsum of each bird. A liquid diet was administered daily (in equal amounts of 0, 4, 8, 12, and 16 hours) for 14 days without adverse effects. On day 15, the catheters were removed, and the birds immediately resumed normal consumption of a pigeon ration and water diet. Although 4 of the 5 birds had minor weight loss, dietary alterations probably could be used on an individual basis to alleviate this problem. After oral alimentation was resumed, the 5 birds exceeded their initial body weight within 7 days. Four weeks after catheter removal, positive-contrast radiographic evaluations indicated that the duodenum of each pigeon appeared normal. Needle catheter duodenostomy was a viable method of alimentation in the domestic pigeon. This technique should be applicable for other avian species requiring bypass of the upper gastrointestinal tract proximal to the region of catheter insertion in the duodenum.

  13. A novel suture method to place and adjust peripheral nerve catheters

    DEFF Research Database (Denmark)

    Rothe, C.; Steen-Hansen, C.; Madsen, M. H.

    2015-01-01

    We have developed a peripheral nerve catheter, attached to a needle, which works like an adjustable suture. We used in-plane ultrasound guidance to place 45 catheters close to the femoral, saphenous, sciatic and distal tibial nerves in cadaver legs. We displaced catheters after their initial...

  14. Total parenteral alimentation via indwelling umbilical catheters in the newborn period.

    Science.gov (United States)

    Hall, R T; Rhodes, P G

    1976-01-01

    Total parenteral alimentation (TPA) was delivered to 80 infants via indwelling umbilical artery and to 9 via indwelling umbilical venous catheters. The primary indication for catheter placement and maintenance was monitoring of arterial blood gases (umbilical venous catheter tip in left atrium) in a group of sick neonates requiring increased inspired oxygen or assisted ventilation. Results were compared with those from 23 infants who had tunnelled jugular catheters for a variety of chronic medical and surgical problems preventing gastric or intestinal feeding. A mean weight gain was achieved in both groups. Mortality and morbidity rates were similar in both groups. The most common complications were infection and thrombotic phenomena. Metabolic complications were few. It is concluded that infusing TPA solutions via indwelling umbilical catheters presents no greater risk than infusion via tunnelled jugular catheters, and provides a method for supplying adequate caloric intake for growth during the acute stage of illness. PMID:827978

  15. Using an indwelling catheter for the domiciliary management of malignant effusions

    Directory of Open Access Journals (Sweden)

    Ramkumar P

    2003-01-01

    Full Text Available Background: Many patients with malignant pleural effusions and ascites require repeated hospital visits for paracentesis. Materials and Methods: Patients and caregivers were taught to drain malignant effusions at home, using an indwelling catheter inserted into the pleural/ peritoneal cavity. The catheter, (ARROW 14 wire gauge with three additional side holes made to prevent blockage was inserted using the Seldenger technique for central venous cannulation and secured with a stitch. A three way stopcock was used to regulate fluid drainage. The caregiver was taught to do biweekly dressings with antiseptic ointment. Results: The catheter has been used in 200 patients over a period of five years. Two patients developed infections in the pleural cavity, which were managed with antibiotics. Two patients needed catheter change because of blockage. Other patients retained the catheter till last follow up or death. The procedure can be carried out as a day case. This article describes practical guidelines for inserting and maintaining the catheter.

  16. The effect of interruptions and prolonged treatment time in radiotherapy for nasopharyngeal carcinoma

    International Nuclear Information System (INIS)

    Kwong, Dora L.W.; Sham, Jonathan S.T.; Chua, Daniel T.T.; Choy, Damon T.K.; Au, Gordon K.H.; Wu, P.M.

    1997-01-01

    Purpose: The effect of interruptions and prolonged overall treatment time in radiotherapy for nasopharyngeal carcinoma and the significance of timing of interruption was investigated. Methods and Materials: Treatment records of 229 patients treated with continuous course (CC) and 567 patients treated with split course (SC) radiotherapy for nonmetastatic NPC were reviewed. Overall treatment time without inclusion of time for boost was calculated. Treatment that extended 1 week beyond scheduled time was considered prolonged. Outcome in patients who completed treatment 'per schedule' were compared with those who had 'prolonged' treatment. Because of known patient selection bias between CC and SC, patients on the two schedules were analyzed separately. Multivariate analysis was performed for patients on SC. Total number of days of interruption, age, sex, T and N stage, and the use of boost were tested for the whole SC group. Analysis on the effect of timing of interruption was performed in a subgroup of 223 patients on SC who had a single unplanned interruption. Timing of interruption, either before or after the fourth week for the unplanned interruption, was tested in addition to the other variables in multivariate analysis for this subgroup of SC. Results: Twenty-seven (11.8%) patients on CC and 96 (16.9%) patients on SC had prolonged treatment. Patients on SC who had prolonged treatment had significantly poorer loco-regional control rate and disease free survival when compared with those who completed radiotherapy per schedule (p = 0.0063 and 0.001, respectively, with adjustment for stage). For CC, the effect of prolonged treatment on outcome was not significant. The small number of events for patients on CC probably account for the insignificant finding. The number of days of interruption was confirmed as prognostic factor, independent of T and N stages, for loco-regional control and disease-free survival in multivariate analysis for SC. The hazard rate for loco

  17. Correction of malfunctioning peritoneal dialysis catheter with guidewire and stiffener under fluoroscopic guidance

    International Nuclear Information System (INIS)

    Lee, Seung Ryong; Baek, Kyong Hee; Jung, Gyoo Sik; Huh, Jin Do; Joh, Young Duk; Rim, Hark

    1997-01-01

    To determine the efficacy of correction of a malfunctioning peritoneal dialysis catheter with guidewire and stiffener under fluoroscopic guidance. Between November 1994 and March 1997, we performed 15 manipulations in 12 patients in whom a dual-cuff, straight Tenckhoff peritoneal dialysis catheter had been implanted due to chronic renal failure. The causes of catheter malfunctioning were inadequate drainage of the dialysate(n=14) and painful dialysis(n=1). Under fluoroscopic guidance, adhesiolysis and repositioning of the malfunctioning catheter were performed with an Amplatz Super Stiff guidewire and the stiffener from a biliary drainage catheter. The results of procedures were categorized as either immediate or durable success, this latter being defined as adequate catheter function for at least one month after the procedure. Immediate success was achieved in 14 of 15 procedures (93%), and durable success in 7 of 15(47%). The mean duration of catheter function was 157 (range, 30 to 578) days. After manipulation, abdominal pain developed in eight patients and peritonitis in two, but with conservative treatment, these symptoms improved. The correction of a malfunctioning peritoneal dialysis catheter with guidewire and stiffener under fluoroscopic guidance is an effective means of restoring catheter function and may be an effective alternative to surgical reimplantation of the catheter, or hemodialysis

  18. Correction of malfunctioning peritoneal dialysis catheter with guidewire and stiffener under fluoroscopic guidance

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Seung Ryong; Baek, Kyong Hee; Jung, Gyoo Sik; Huh, Jin Do; Joh, Young Duk; Rim, Hark [Kosin Medical College, Pusan (Korea, Republic of)

    1997-11-01

    To determine the efficacy of correction of a malfunctioning peritoneal dialysis catheter with guidewire and stiffener under fluoroscopic guidance. Between November 1994 and March 1997, we performed 15 manipulations in 12 patients in whom a dual-cuff, straight Tenckhoff peritoneal dialysis catheter had been implanted due to chronic renal failure. The causes of catheter malfunctioning were inadequate drainage of the dialysate(n=14) and painful dialysis(n=1). Under fluoroscopic guidance, adhesiolysis and repositioning of the malfunctioning catheter were performed with an Amplatz Super Stiff guidewire and the stiffener from a biliary drainage catheter. The results of procedures were categorized as either immediate or durable success, this latter being defined as adequate catheter function for at least one month after the procedure. Immediate success was achieved in 14 of 15 procedures (93%), and durable success in 7 of 15(47%). The mean duration of catheter function was 157 (range, 30 to 578) days. After manipulation, abdominal pain developed in eight patients and peritonitis in two, but with conservative treatment, these symptoms improved. The correction of a malfunctioning peritoneal dialysis catheter with guidewire and stiffener under fluoroscopic guidance is an effective means of restoring catheter function and may be an effective alternative to surgical reimplantation of the catheter, or hemodialysis.

  19. The left atrial catheter: its uses and complications.

    Science.gov (United States)

    Leitman, B S; Naidich, D P; McGuinness, G; McCauley, D I

    1992-11-01

    The authors describe the radiographic appearance of the left atrial catheter, a widely used postsurgical intracardiac device. Recognition of the characteristic appearance of this catheter should be of value in detection of potential complications, including line fracture with resultant retention and/or embolization, infection, prosthetic valve dysfunction, and even cardiac tamponade.

  20. A prototype catheter designed for ultraviolet C disinfection

    DEFF Research Database (Denmark)

    Bak, Jimmy; Begovic, Tanja

    2013-01-01

    UVC light exposure, sampling and plate counting. Findings Two minutes of UVC exposure was sufficient to obtain 4 log10 disinfection for the full-length prototype catheter. This exposure corresponds to ∼40 mJ/cm2 at the catheter tip and indicates that even shorter exposure times can be achieved...

  1. Development of A MEMS Based Manometric Catheter for Diagnosis of Functional Swallowing Disorders

    International Nuclear Information System (INIS)

    Hsu, H Y; Hariz, A J; Omari, T; Teng, M F; Sii, D; Chan, S; Lau, L; Tan, S; Lin, G; Haskard, M; Mulcahy, D; Bakewell, M

    2006-01-01

    Silicon pressure sensors based on micro-electro-mechanical-systems (MEMS) technologies are gaining popularity for applications in bio-medical devices. In this study, a silicon piezo-resistive pressure sensor die is used in a feasibility study of developing a manometric catheter for functional swallowing disorders diagnosis. The function of a manometric catheter is to measure the peak and intrabolus pressures along the esophageal segment during the swallowing action. Previous manometric catheters used the water perfusion technique to measure the pressure changes. This type of catheter is reusable, large in size and the pressure reading is recorded by an external transducer. Current manometric catheters use a solid state pressure sensor on the catheter itself to measure the pressure changes. This type of catheter reduces the discomfort to the patient but it is reusable and is very expensive. We carried out several studies and experiments on the MEMS-based pressure sensor die, and the results show the MEMS-based pressure sensors have a good stability and a good linearity output response, together with the advantage of low excitation biasing voltage and extremely small size. The MEMS-based sensor is the best device to use in the new generation of manometric catheters. The concept of the new MEMS-based manometric catheter consists of a pressure sensing sensor, supporting ring, the catheter tube and a data connector. Laboratory testing shows that the new calibrated catheter is capable of measuring pressure in the range from 0 to 100mmHg and maintaining stable condition on the zero baseline setting when no pressure is applied. In-vivo tests are carried out to compare the new MEMS based catheter with the current version of catheters used in the hospital

  2. Culture-dependent and -independent investigations of microbial diversity on urinary catheters

    DEFF Research Database (Denmark)

    Xu, Yijuan; Moser, Claus Ernst; Abu Al-Soud, Waleed

    2012-01-01

    Catheter-associated urinary tract infection is caused by bacteria, which ascend the catheter along its external or internal surface to the bladder and subsequently develop into biofilms on the catheter and uroepithelium. Antibiotic-treated bacteria and bacteria residing in biofilm can be difficult...... to culture. In this study we used culture-based and 16S rRNA gene-based culture-independent methods (fingerprinting, cloning, and pyrosequencing) to determine the microbial diversity of biofilms on 24 urinary catheters. Most of the patients were catheterized for...

  3. Micrococcus-associated central venous catheter infection in patients with pulmonary arterial hypertension.

    Science.gov (United States)

    Oudiz, Ronald J; Widlitz, Allison; Beckmann, X Joy; Camanga, Daisy; Alfie, Jose; Brundage, Bruce H; Barst, Robyn J

    2004-07-01

    To determine the incidence of catheter-related infection in patients with pulmonary arterial hypertension (PAH) receiving epoprostenol (EPO), and to note an etiologic role for Micrococcus spp, which is rarely reported as a pathogen in the medical literature. Observational study. Two PAH specialty treatment centers, Harbor-UCLA Medical Center (Torrance, CA), and the College of Physicians and Surgeons, Columbia University (New York, NY). A total of 192 patients with PAH receiving continuous therapy with IV EPO. From 1987 to 2000, 192 patients with PAH received infusions of EPO via central venous catheter. Catheter care included regular dressing changes with dry gauze using a sterile procedure, without the use of flushes. Patients were asked to report on known infections and treatments, and symptoms. All infections were verified by a telephone call to the patient, care provider, and microbiology laboratory whenever possible. There were 335,285 catheter days (mean +/- SD, 1,325 +/- 974 catheter days). There were 88 clinical catheter infections with 51 blood culture-positive infections, necessitating catheter removal in 38 instances. The following pathogens were isolated: Staphylococcus aureus (25); Micrococcus spp (14); mixed flora (3); coagulase-negative Staphylococcus spp (2); Corynebacterium spp (2); Serratia marcessens (1); Enterobacter spp (1); Pseudomonas aeruginosa (1); enterococci (1); and unidentified Gram-positive cocci (1). The catheter infection rate was 0.26 per 1,000 catheter days. The use of long-term therapy with continuous EPO appears to be associated with a low incidence of catheter-related infections. Micrococcus spp were the second most common etiologic agent. Caregivers managing patients with PAH must be aware of the risk of catheter infection, as it may contribute to the morbidity and mortality associated with the use of EPO. When isolated, Micrococcus spp should not be viewed as a contaminant, but rather as a true pathogen that may require

  4. Urinary catheterization diary – A useful tool in tracking causes of non-deflating Foley catheter

    Directory of Open Access Journals (Sweden)

    C.O. Okorie

    2015-06-01

    Conclusions: Most urinary catheters marketed in developing countries are unidentifiable after unpacking. A catheterization diary is a useful tool for solving catheter-related problems, and its application in health-care facilities should be encouraged. Companies marketing Foley catheters should print the catheter name on both the catheter packaging and on the catheter itself.

  5. Microbiocidal effects of various taurolidine containing catheter lock solutions

    NARCIS (Netherlands)

    Olthof, E.D.; Nijland, R van; Gulich, A.F.; Wanten, G.J.A.

    2015-01-01

    BACKGROUND & AIMS: We have recently shown that a catheter lock solution containing taurolidine dramatically decreases catheter-related bloodstream infections (CRBSI) in patients on home parenteral nutrition (HPN) when compared to heparin. Since several taurolidine formulations are commercially

  6. Effect of prolonged coldness on survival and fertility of Drosophila melanogaster.

    Directory of Open Access Journals (Sweden)

    Robin J Mockett

    Full Text Available The laboratory fruit fly, Drosophila melanogaster, is used widely in biological research, but the requirement to maintain stocks with a roughly biweekly generation time imposes substantial burdens of labor, potential cross-contamination and mutation accumulation. The purpose of this study was to assess the impact of prolonged cold stress or milder cooling on survivorship and fertility. The hypothesis was that cold storage would result in postponement of reproduction and a longer generation time. Flies of several genotypes were maintained continuously at 4-11 °C; recovery rates and subsequent yields of adult progeny were recorded. Adults and pupae of a relatively long-lived y w lineage were more resistant to severe cold stress than embryos and larvae. Adults exhibited minimal mortality up to at least 5 d at 4 °C, 20 d at 8 °C and 12 weeks at 11 °C. Reproduction did not occur at these temperatures, but progeny were obtained after recovery at 25 °C. At all temperatures, chilling caused a rapid, severe and progressive decrease in fertility during the first 2 d of recovery. The impact on fertility during the subsequent 2-4 d was much milder and it occurred only after prolonged incubation at low temperatures. The total reproductive output during the first 6 d of recovery was sufficient to replace the parental population after 12 weeks at 11 °C. Food spoilage had an unexpectedly low impact on survivorship and fertility, and the reproductive output of F1 progeny was not affected by storing parental flies at 11 °C for 8-10 weeks. In the case of w1118 flies, replacement of the parents within 6 d of recovery was possible for up to 60 d at 11 °C. Among less fertile genotypes, replacement of the parents was possible within 18 d after 4-10 weeks at 11 °C. These results show that the 2-week maintenance interval of stocks of D. melanogaster can be extended 3-7 fold, at least for 1 generation, by storing adult flies at 11 °C.

  7. Empyema and Effusion: Outcome of Image-Guided Small-Bore Catheter Drainage

    International Nuclear Information System (INIS)

    Keeling, A. N.; Leong, S.; Logan, P. M.; Lee, M. J.

    2008-01-01

    Empyema and complicated pleural effusion represent common medical problems. Current treatment options are multiple. The purpose of this study was to access the outcome of image-guided, small-bore catheter drainage of empyema and effusion. We evaluated 93 small-bore catheters in 82 patients with pleural effusion (n = 30) or empyema (n = 52), over a 2-year period. Image guidance was with ultrasound (US; n = 56) and CT (n = 37). All patients were followed clinically, with catheter dwell times, catheter outcome, pleural fluid outcome, reinsertion rates, and need for urokinase or surgery recorded. Ninety-three small-bore chest drains (mean=10.2 Fr; range, 8.2-12.2 Fr) were inserted, with an average dwell time of 7.81 days for empyemas and 7.14 days for effusions (p > 0.05). Elective removal rates (73% empyema vs 86% effusions) and dislodgement rates (12% empyema vs 13% effusions) were similar for both groups. Eight percent of catheters became blocked and 17% necessitated reinsertion in empyemas, with no catheters blocked or requiring reinsertion in effusions (p < 0.05). Thirty-two patients (51%) required urokinase in the empyema group, versus 2 patients (6%) in the effusion group (p < 0.05). All treatment failures, requiring surgery, occurred in the empyema group (19%; n = 12; p < 0.05). In conclusion, noninfected pleural collections are adequately treated with small-bore catheters, however, empyemas have a failure rate of 19%. The threshold for using urokinase and larger-bore catheters should be low in empyema

  8. Hematologic patients' clinical and psychosocial experiences with implanted long-term central venous catheter

    DEFF Research Database (Denmark)

    Møller, Tom; Adamsen, Lis

    2010-01-01

    A significant decrease in catheter-related infections was demonstrated in our earlier randomized controlled trial of central venous catheter (CVC) care in hematologic patients.......A significant decrease in catheter-related infections was demonstrated in our earlier randomized controlled trial of central venous catheter (CVC) care in hematologic patients....

  9. Bridging Locoregional Therapy Prolongs Survival in Patients Listed for Liver Transplant with Hepatocellular Carcinoma

    Energy Technology Data Exchange (ETDEWEB)

    Xing, Minzhi [Yale School of Medicine, Interventional Radiology, Department of Radiology and Biomedical Imaging (United States); Sakaria, Sonali [Emory University School of Medicine, Division of Digestive Diseases, Department of Medicine (United States); Dhanasekaran, Renumathy [Stanford University School of Medicine, Division of Gastroenterology and Hepatology (United States); Parekh, Samir; Spivey, James [Emory University School of Medicine, Division of Digestive Diseases, Department of Medicine (United States); Knechtle, Stuart J. [Duke University School of Medicine, Division of Transplant Surgery, Department of Surgery (United States); Zhang, Di [University of Pittsburgh, Department of Biostatistics, Graduate School of Public Health (United States); Kim, Hyun S., E-mail: kevin.kim@yale.edu [Yale School of Medicine, Interventional Radiology, Department of Radiology and Biomedical Imaging (United States)

    2017-03-15

    Background and AimsTo evaluate the long-term survival benefit of bridging locoregional therapy (LRT) prior to orthotopic liver transplantation (OLT) in patients with hepatocellular carcinoma (HCC) within Milan criteria.MethodsOur transplant center registry was studied for all HCC patients within the Milan criteria who were listed for OLT from 1998 to 2013. Baseline clinical characteristics and median overall survival (OS) were calculated and stratified by LRT, OLT status, and wait times. Survival analysis was conducted using Kaplan–Meier estimation and log-rank test.ResultsOf 265 listed, 205 underwent OLT (mean follow-up 7.6 years). Of 205, 111 received bridging LRT (A), and 94 did not (B). Both were similar in demographics and tumor characteristics (p > 0.05). Median OS from HCC for A/B were 86.4 vs. 68.9 months (p = 0.01). Median OS from OLT for A/B were 74.6 vs. 63.6 months (p = 0.03). On multivariate analysis, independent predictors for survival from HCC were bridging LRT (p = 0.002) and high wait time (p = 0.008); independent predictors for survival from OLT were bridging LRT (p = 0.005) and high wait time (p = 0.005). Of 60 who were listed but did not undergo transplant, 44 received LRT (C) and 16 received best supportive care (D). Median OS from HCC for C/D were 37.1 vs. 24.8 months (p = 0.03).ConclusionsBridging LRT and high wait times were independent positive prognostic factors for survival from HCC diagnosis and OLT.

  10. Bridging Locoregional Therapy Prolongs Survival in Patients Listed for Liver Transplant with Hepatocellular Carcinoma

    International Nuclear Information System (INIS)

    Xing, Minzhi; Sakaria, Sonali; Dhanasekaran, Renumathy; Parekh, Samir; Spivey, James; Knechtle, Stuart J.; Zhang, Di; Kim, Hyun S.

    2017-01-01

    Background and AimsTo evaluate the long-term survival benefit of bridging locoregional therapy (LRT) prior to orthotopic liver transplantation (OLT) in patients with hepatocellular carcinoma (HCC) within Milan criteria.MethodsOur transplant center registry was studied for all HCC patients within the Milan criteria who were listed for OLT from 1998 to 2013. Baseline clinical characteristics and median overall survival (OS) were calculated and stratified by LRT, OLT status, and wait times. Survival analysis was conducted using Kaplan–Meier estimation and log-rank test.ResultsOf 265 listed, 205 underwent OLT (mean follow-up 7.6 years). Of 205, 111 received bridging LRT (A), and 94 did not (B). Both were similar in demographics and tumor characteristics (p > 0.05). Median OS from HCC for A/B were 86.4 vs. 68.9 months (p = 0.01). Median OS from OLT for A/B were 74.6 vs. 63.6 months (p = 0.03). On multivariate analysis, independent predictors for survival from HCC were bridging LRT (p = 0.002) and high wait time (p = 0.008); independent predictors for survival from OLT were bridging LRT (p = 0.005) and high wait time (p = 0.005). Of 60 who were listed but did not undergo transplant, 44 received LRT (C) and 16 received best supportive care (D). Median OS from HCC for C/D were 37.1 vs. 24.8 months (p = 0.03).ConclusionsBridging LRT and high wait times were independent positive prognostic factors for survival from HCC diagnosis and OLT.

  11. Minimizing Hemodialysis Catheter Dysfunction: An Ounce of Prevention

    Directory of Open Access Journals (Sweden)

    Timmy Lee

    2012-01-01

    Full Text Available The maintenance of tunneled catheter (TC patency is critical for the provision of adequate hemodialysis in patients who are TC-dependent. TC dysfunction results in the need for costly and inconvenient interventions, and reduced quality of life. Since the introduction of TCs in the late 1980s, heparin catheter lock has been the standard prophylactic regimen for the prevention of TC dysfunction. More recently, alternative catheter locking agents have emerged, and in some cases have shown to be superior to heparin lock with respect to improving TC patency and reducing TC-associated infections. These include citrate, tissue plasminogen activator, and a novel agent containing sodium citrate, methylene blue, methylparaben, and propylparaben. In addition, prophylaxis using oral anticoagulants/antiplatelet agents, including warfarin, aspirin, ticlodipine, as well as the use of modified heparin-coated catheters have also been studied for the prevention of TC dysfunction with variable results. The use of oral anticoagulants and/or antiplatelet agents as primary or secondary prevention of TC dysfunction must be weighed against their potential adverse effects, and should be individualized for each patient.

  12. Clinical study of the Erlanger silver catheter--data management and biometry.

    Science.gov (United States)

    Martus, P; Geis, C; Lugauer, S; Böswald, M; Guggenbichler, J P

    1999-01-01

    The clinical evaluation of venous catheters for catheter-induced infections must conform to a strict biometric methodology. The statistical planning of the study (target population, design, degree of blinding), data management (database design, definition of variables, coding), quality assurance (data inspection at several levels) and the biometric evaluation of the Erlanger silver catheter project are described. The three-step data flow included: 1) primary data from the hospital, 2) relational database, 3) files accessible for statistical evaluation. Two different statistical models were compared: analyzing the first catheter only of a patient in the analysis (independent data) and analyzing several catheters from the same patient (dependent data) by means of the generalized estimating equations (GEE) method. The main result of the study was based on the comparison of both statistical models.

  13. Predicting success of catheter drainage in infected necrotizing pancreatitis

    NARCIS (Netherlands)

    Hollemans, Robbert A.; Bollen, Thomas L.; Van Brunschot, Sandra; Bakker, Olaf J.; Ali, Usama Ahmed; Van Goor, Harry; Boermeester, Marja A.; Gooszen, Hein G.; Besselink, Marc G.; Van Santvoort, Hjalmar C.

    2016-01-01

    Introduction: At least 30% of patients with infected necrotizing pancreatitis are successfully treated with catheter drainage alone. It is currently not possible to predict which patients also need necrosectomy. We evaluated predictive factors for successful catheter drainage. Methods: This was a

  14. Predicting Success of Catheter Drainage in Infected Necrotizing Pancreatitis

    NARCIS (Netherlands)

    Hollemans, R.A.; Bollen, T.L.; Brunschot, S. van; Bakker, O.J.; Ali, U. Ahmed; Goor, H. van; Boermeester, M.A.; Gooszen, H.G.; Besselink, M.G.; Santvoort, H.C. van

    2016-01-01

    INTRODUCTION: At least 30% of patients with infected necrotizing pancreatitis are successfully treated with catheter drainage alone. It is currently not possible to predict which patients also need necrosectomy. We evaluated predictive factors for successful catheter drainage. METHODS: This was a

  15. Qureshi-5 Catheter for Complex Supra- and Abdominal-Aortic Catheterization.

    Science.gov (United States)

    Qureshi, Adnan I; Xiao, WeiGang; Liu, HongLiang

    2015-10-01

    The use of previously described catheter technique was expanded to complex supra- and abdominal- aortic catheterizations. A new (Qureshi 5) catheter with curved shape at the distal end that has two lumens was used. One of lumens can accommodate a 0.035-inch guide wire and the second lumen can accommodate a 0.018-inch guide wire and terminates at the beginning of the distal curve of the first lumen. The manipulation and engagement of the curved distal end catheter was facilitated by rotation and movement of the J-shaped 0.018-inch guide wire extended coaxial and beyond the distal end of catheter. Subsequently, either contrast was injected or a 0.035-inch guide wire advanced into the target artery. The catheters were used in one patient to perform diagnostic cerebral and abdominal angiography through a 6F introducer sheath placed in the right common femoral artery. The catheterization was complex because of severe tortuosity of arch and descending aorta secondary to kyphosis. The left and right internal carotid arteries and left and right vertebral arteries, left renal artery, and superior mesenteric artery were catheterized in patient (fluoroscopy time 19:46 min). No complications were observed in the patient. The Qureshi-5 catheter was successful in complex supra- and abdominal-aortic catheterizations.

  16. Catheter design optimization for practical intravascular photoacoustic imaging (IVPA) of vulnerable plaques

    Science.gov (United States)

    Iskander-Rizk, Sophinese; Wu, Min; Springeling, Geert; Mastik, Frits; Beurskens, Robert H. S. H.; van der Steen, Antonius F. W.; van Soest, Gijs

    2018-02-01

    Intravascular photoacoustic/ultrasound imaging (IVPA/US) can image the structure and composition of atherosclerotic lesions identifying lipid-rich plaques ex vivo and in vivo. In the literature, multiple IVPA/US catheter designs were presented and validated both in ex-vivo models and preclinical in-vivo situations. Since the catheter is a critical component of the imaging system, we discuss here a catheter design oriented to imaging plaque in a realistic and translatable setting. We present a catheter optimized for light delivery, manageable flush parameters and robustness with reduced mechanical damage risks at the laser/catheter joint interface. We also show capability of imaging within sheath and in water medium.

  17. Feasibility of Endovascular Radiation Therapy Using Holmium-166 Filled Balloon Catheter in a Swine Hemodialysis Fistula Model: Preliminary Results

    Energy Technology Data Exchange (ETDEWEB)

    Won, Jong Yun; Lee, Kwang Hun; Lee, Do Yun [Dept. of Radiology, Research Institute of Radiological Science, Yensei University College of Medicine, Seoul (Korea, Republic of); Kim, Myoung Soo [Dept. of Radiology, Yensei University College of Medicine, Seoul (Korea, Republic of); Kang, Byung Chul [Dept. of Radiology, Internal Medicine, EwhaWoman' s University School of Medicine, Seoul (Korea, Republic of); Kim, Seung Jung [Dept. of Internal Medicine, EwhaWoman' s University School of Medicine, Seoul (Korea, Republic of)

    2011-08-15

    To describe how to make a swine hemodialysis fistula model and report our initial experience to test the feasibility of endovascular radiation therapy with Holmium-166 filled balloon catheters. The surgical formation of arterio-venous fistula (AVF) was performed by end-to-side anastomosis of the bilateral jugular vein and carotid artery of 6 pigs. After 4 weeks, angiograms were taken and endovascular radiation was delivered to the venous side of AVF with Holmium-166 filled balloon catheters. Pigs were sacrificed 4 weeks after the radiation and AVFs were harvested for histological examination. All animals survived without any morbidity during the experimental periods. The formation of fistula on the sides of necks was successful in 11 of the 12 pigs (92%). One AVF failed from the small jugular vein. On angiograms, 4 of the 11 AVFs showed total occlusion or significant stenosis and therefore, endovascular radiation could not be performed. Of 7 eligible AVFs, five underwent successful endovascular radiation and two AVFs did not undergo radiation for the control. Upon histologic analysis, one non-radiated AVF showed total occlusion and others showed intimal thickening from the neointimal hyperplasia. Formation of the swine carotid artery-jugular vein hemodialysis fistula model was successful. Endovascular radiation using a Holmium-166 filled balloon catheter was safe and feasible.

  18. Peripherally inserted central catheters. Guidewire versus nonguidewire use: a comparative study.

    Science.gov (United States)

    Loughran, S C; Edwards, S; McClure, S

    1992-01-01

    To date, no research articles have been published that explore the practice of using guidewires for placement of peripherally inserted central catheters. The literature contains speculations regarding the pros and cons of guidewire use. However, no studies to date have compared patient outcomes when peripherally inserted central catheter lines are inserted with and without guidewires. To examine the use of guidewires for peripherally inserted central lines, a comparative study was conducted at two acute care facilities, one using guidewires for insertion and one inserting peripherally inserted central catheter lines without guidewires. 109 catheters were studied between January 1, 1990 and January 1, 1991. The primary focus of this study was to examine whether guidewire use places patients at higher risk for catheter-related complications, particularly phlebitis. No significant differences in phlebitis rates between the two study sites were found. Other catheter-related and noncatheter-related complications were similar between the two facilities. The results of this study do not support the belief that guidewire use increases complication rates.

  19. Successful Use of Modified Suprapubic Catheter to Rescue Prostatorectal Fistula

    Directory of Open Access Journals (Sweden)

    Yi-Chun Chiu

    2008-06-01

    Full Text Available Prostatorectal fistula is a complication following radiotherapy. It remains a clinical challenge to treat because most patients experience a poor quality of life. This case report discusses a modified suprapubic catheter for use in a patient with a prostatorectal fistula that developed after radiotherapy for localized prostate cancer. It is an inexpensive, easily available, and more patient-tolerable catheter that improves quality of life. Herein, we describe the development of this catheter.

  20. Longer Duration of Urinary Catheterization Increases Catheter-Associated Urinary Tract Infection in PICU.

    Science.gov (United States)

    Fukuoka, Kahoru; Furuichi, Mihoko; Ito, Kenta; Morikawa, Yoshihiko; Watanabe, Ichiro; Shimizu, Naoki; Horikoshi, Yuho

    2018-06-13

    Catheter-associated urinary tract infections account for 30% of healthcare-associated infections. To date, few studies have addressed pediatric catheter-associated urinary tract infection in PICUs. The aim of our study was to assess the risk of catheter-associated urinary tract infection in relation to the duration of catheterization in the PICU. Retrospective cohort study. PICU at a tertiary children's hospital. Our study was conducted between April 2012 and June 2015 at Tokyo Metropolitan Children's Medical Center in Japan. Children in the PICU with an urethral catheter were included. Catheter-associated urinary tract infection cases were defined according to the National Healthcare Safety Network criteria. The patients' demographic data and isolated organisms were reviewed. Duration of catheterization and the catheter-associated urinary tract infection occurrence rate were analyzed. None. Among 1,890 catheterizations, 23 catheter-associated urinary tract infection cases were identified. The overall occurrence rate was 2.35/1,000 catheter-days. Among the patients with catheter-associated urinary tract infection, 13 were boys. The median age was 11 months (interquartile range, 7-35 mo), and the median duration of catheterization was 7 days (interquartile range, 5-12 d). The isolated bacteria were Escherichia coli (26.5%), Enterococcus faecalis (17.6%), and Klebsiella pneumoniae (11.8%). Two species were isolated in each of 11 cases (47.8%). Each additional day of catheterization increased the risk of catheter-associated urinary tract infection (odds ratio, 1.06; 95% CI, 1.02-1.10, and odds ratio adjusted for contact precaution status and surgical procedures was 1.05; 95% CI, 1.01-1.09). Longer duration of catheterization increased the risk of catheter-associated urinary tract infection by 5% each day at the PICU. Prompt removal of the urethral catheter is strongly recommended whenever feasible.

  1. Percutaneous transvenous retrieval of CVP catheter emboli in S. V. C.-A case report-

    International Nuclear Information System (INIS)

    Zeon, Seok Kil; Lee, Deock Hee; Kim, Hong; Kim, Ok Bae

    1987-01-01

    The increasing use of the indwelling venous catheters and cardiovascular catheters has led to many iatrogenic complications. One of the most serious complications is catheter embolization, caused by inadvertent fracture of a fragment of catheter remaining within cardiovascular systems. In the catheter embolization, there are serious consequence such as thromboembolism, sepsis, cardiac arrhythmia and others. Fisher and Ferreyro (1978) reported a 71% incidence of serious morbidity or death following to intravascular foreign bodies in patients without removal. The authors experienced a case of retained central venous pressure monitoring catheter (CVP catheter) fragment extending from superior vena cava to hepatic segment of inferior vena cava. CVP catheter wa introduced into right subclavian venous route for hyperalimentation, because of poor general condition for operation of afferent loop syndrome following to resection of the gastric carcinoma with Billoth II operation (5 years age). On attempting removal of CVP catheter on recovery from afferent loop syndrome, a large portion of the CVP catheter was cut off in S.V.C. Percutaneous puncture of right femoral vein with Seldinger technique was done and 9F introducer sheath was indwelled. The helical basket of Dotter intravascular retriever set was advance through the sheath up to retained CVP catheter, and it was grasped. The retrieved CVP catheter fragment showed several tiny blood clots on surface. The patient was uneventfully recovered and was discharged asymptomatic on second day of the procedure.

  2. [Coronary angioplasty with the Monorail system via 6 French diagnostic catheters].

    Science.gov (United States)

    Villavicencio, R; González, H; López, J; Zavala, E; Ban Hayashi, E B; Gaspar, J; Gil, M; Martínez Ríos, M A

    1994-01-01

    We studied the use of "Monorail" system with Express (Scimed) balloon catheters for coronary angioplasty through 6 French (F) "high-flow" diagnostic catheters (Novoste, USCI). Prospectively, from July 1992 to January 1993, angioplasty of 31 lesions in 24 patients was attempted (1.3 lesions/procedure). Twenty procedures were of a single lesion and four were multi-vessel angioplasty. Fourteen lesions were in the left anterior descending or in its branches, 10 in the left circumflex or in its branches, 6 in the right coronary artery, and one in the distal anastomosis of an internal mammary artery graft. Thirteen lesions (42%) were type A, 17 (55%) type B and one (3%) type C. Balloon sizes varied between 2.0 and 3.5 mm. Twenty-nine lesions could be successfully dilated (93.5%); two cases were unsuccessful due to an acute occlusion in one and residual stenosis of more than 50% in the other. For only one case, another balloon catheter different from the "Monorail" system was necessary to complete a multi-vessel angioplasty. Coronary visualization and manipulation of the balloon through the tip of the diagnostic catheter were satisfactory in all cases, except with the 3.5 mm balloon catheter. Coronary angioplasty with "Monorail" system balloon catheters through 6 F "high-flow" diagnostic catheters is feasible and provides a high success rate in simple and moderately complex selected lesions, including multivessel angioplasty with advantages of smaller artery punction and the feasibility of performing coronary angioplasty with the same catheter used for diagnostic angiography.

  3. Survival benefits of post-fledging care: experimental approach to a critical part of avian reproductive strategies.

    Science.gov (United States)

    Grüebler, Martin U; Naef-Daenzer, Beat

    2010-03-01

    1. Caring for offspring beyond leaving the nest is an important but under-studied part of avian life histories. Theory predicts that prolonged post-fledging parental care should yield fitness benefits such as increased fledgling survival. Post-fledging care is also costly in terms of time and energy available for subsequent reproduction, moult or migration. So far, direct measurements of the fitness effects of the duration of post-fledging parental care are lacking. 2. In a partial cross-fostering experiment, barn swallow (Hirundo rustica) chicks were exchanged among broods close to fledging. Thereby, we separated the effects of post-fledging care from those of pre-fledging origin on juvenile survival. 3. Prolonging post-fledging care substantially increased juvenile survival up to 3 weeks post-fledging. Juvenile mortality was maximal in the days following the termination of parental care, and prolonging care delayed and reduced this peak mortality. Survival of fledglings experiencing 6 days of care was Phi = 0.227, whereas fledglings experiencing 14 days of care showed a survival of Phi = 0.571. 4. Offspring from pairs providing short care showed lower post-fledging survival than did offspring from pairs providing long care, irrespective of the actual duration of care experienced. This gives evidence for an additional survival effect of pre-fledging factors associated with the parental duration of care. 5. The results suggest that differential survival in relation to post-fledging parental care is a major fitness component. This relationship has profound effects on the reproductive trade-offs underlying the evolution of avian life histories.

  4. Catheter-free Period Over 2 Days Is Associated with Better Outcome in Catheter-related Bloodstream Infection due to Candida

    OpenAIRE

    Matsuo, Takahiro; Mori, Nobuyoshi; Hoshino, Eri; Sakurai, Aki; Furukawa, Keiichi

    2017-01-01

    Abstract Background Regardless of active antifungal drugs, mortality of candidemia remains high. Although it is well-known that central venous catheter (CVC) is one of the most important risk factors of candidemia and should be removed immediately, little is known about optimal timing of CVC replacement after removal. Here, we analyzed contributing risk factors associated with 30-day mortality for catheter-related bloodstream infection (CRBSI) due to candida and optimal timing of CVC replacem...

  5. Depression and Liver Transplant Survival.

    Science.gov (United States)

    Meller, William; Welle, Nicole; Sutley, Kristen; Thurber, Steven

    Patients who underwent liver transplantation and experienced clinical depression have heretofore evinced lower survival rates when compared to nondepressed counterparts. To investigate the hypothesis that transplant patients who seek and obtain medical treatment for depression would circumvent the prior reduced survival findings. A total of 765 patients with liver transplants were scrutinized for complications following transplantation. Further, 104 patients experienced posttransplant depression as manifested by diagnosis and treatment by medical personnel. Survival analyses were conducted comparing hazard and survival curves for these selected individuals and the remainder of transplant patients. Contrary to prior data and consistent with the aforementioned hypothesis, median survival durations, survival curves, and hazard functions (controlling for age and prolonged posttransplant survival for the depressed patients were better. The improved survival for the depressed patients may simply be related to an amelioration of depressed symptoms via antidepressant medications. However, this interpretation would only be congruent with reduced hazard, not elevated survival, beyond the norm (median) for other transplant participants. Assuming the reliability and generalization of our findings, perhaps a reasonable and compelling interpretation is that combined with the effectiveness of antidepressant medications, the seeking and receiving treatment for depression is a type of proxy measure of a more global pattern of adherence to recommended posttransplant medical regimens. Copyright © 2017 The Academy of Psychosomatic Medicine. Published by Elsevier Inc. All rights reserved.

  6. Initial experience with the Europass: a new ultra-low profile monorail balloon catheter.

    Science.gov (United States)

    Zimarino, M; Corcos, T; Favereau, X; Tamburino, C; Toussaint, M; Spaulding, C; Guérin, Y

    1994-09-01

    One of the causes for percutaneous transluminal coronary angioplasty (PTCA) failure is the inability to cross the lesion with the balloon catheter after guidewire positioning. The Europass coronary angioplasty catheter is a monorail Duralyn balloon catheter developed to enhance lesion crossability and to overcome this limitation. This system was evaluated in 50 patients in which target lesions were chronic total coronary occlusions (12 cases) or stenoses that could not be reached or crossed by other new monorail balloon catheters. Overall procedural success was obtained in 49/50 patients (98%), using a single Europass balloon catheter in 46/50 patients (92%), with no in-hospital complications. Its low profile, small distal shaft, and excellent trackability allowed successful angioplasty in cases where other catheters failed. This balloon catheter represents a significant advance in angioplasty technology and can be considered as a first-choice device for a safe and expeditious single-operator procedure.

  7. Risk Factors for Catheter Associated Urinary Tract Infections in a Pediatric Institution.

    Science.gov (United States)

    Lee, Nora G; Marchalik, Daniel; Lipsky, Andrew; Rushton, H Gil; Pohl, Hans G; Song, Xiaoyan

    2016-04-01

    Catheter associated urinary tract infections are an essential measure for health care quality improvement that affects reimbursement through hospital acquired condition reduction programs in adult patients. With the mounting importance of preventing such infections we evaluated risk factors for acquiring catheter associated urinary tract infections in pediatric patients. All catheter associated urinary tract infections were identified at 1 pediatric institution from September 2010 to August 2014 from a prospective database maintained by the infection control office. To identify risk factors patients with a catheter associated urinary tract infection were individually matched to control patients with a urinary catheter but without infection by age, gender, date and the hospital location of the infection in 1:2 fashion. A total of 50 patients with catheter associated urinary tract infection were identified and matched to 100 control patients. Compared to controls the patients with infection were more likely to have a catheter in place for longer (2.9 days, OR 1.08, 95% CI 1.01, 1.15, p = 0.02). They were also more likely to be on contact precautions (OR 4.00, 95% CI 1.73, 9.26, p = 0.001), and have concurrent infections (OR 3.04, 95% CI 1.39, 6.28, p = 0.005) and a history of catheterization (OR 3.24, 95% CI 1.55, 6.77, p = 0.002). Using a conditional multivariate regression model the 3 most predictive variables were duration of catheter drainage, contact isolation status and history of catheterization. Longer duration of urinary catheter drainage, positive contact precautions status and a history of catheterization appear to be associated with a higher risk of catheter associated urinary tract infection in hospitalized pediatric patients. Physicians should attempt to decrease the duration of catheterization, especially in patients who meet these criteria, to minimize the risk of catheter associated urinary tract infection. Copyright © 2016 American Urological

  8. Urinary catheter related nosocomial infections in paediatric intensive care unit.

    Directory of Open Access Journals (Sweden)

    Tullu M

    1998-04-01

    Full Text Available The present prospective study was carried out in the Paediatric Intensive Care Unit (PICU of a tertiary care teaching hospital in Mumbai. The objective was to determine the incidence, risk factors, mortality and organisms responsible for urinary catheter related infections (UCRI. Colonization and/or bacteriuria was labelled as urinary catheter related infection (UCRI. Forty-four patients with 51 urinary catheters were studied. Incidence of UCRI was 47.06%. Age, female sex and immunocompromised status did not increase the risk of UCRI. Duration of catheter in-situ and duration of stay in the PICU were associated with higher risk of UCRI. The mortality was not increased by UCRI. Commonest organism isolated in UCRI was E. coli, which had maximum susceptibility to nitrofurantoin and amikacin.

  9. Increased survival with enzalutamide in prostate cancer after chemotherapy

    NARCIS (Netherlands)

    H.I. Scher (Howard I.); K. Fizazi (Karim); F. Saad (Fred); M.-E. Taplin (Mary-Ellen); C.N. Sternberg (Cora); K. Miller (Kurt); R. de Wit (Ronald); P.F.A. Mulders (P. F A); K.N. Chi (Kim Nguyen); N.D. Shore (Neal); A.J. Armstrong (Andrew); T.W. Flaig (Thomas); A. Flechon (Aude); P. Mainwaring (Paul); M. Fleming; J.D. Hainsworth (John); M. Hirmand (Mohammad); B. Selby (Bryan); L. Seely (Lynn); J.S. de Bono (Johann)

    2012-01-01

    textabstractBACKGROUND: Enzalutamide (formerly called MDV3100) targets multiple steps in the androgen-receptor-signaling pathway, the major driver of prostate-cancer growth. We aimed to evaluate whether enzalutamide prolongs survival in men with castration-resistant prostate cancer after

  10. Percutaneous transhepatic biliary drainage for hilar cholangiocarcinoma

    International Nuclear Information System (INIS)

    Qian Xiaojun; Jin Wenhui; Dai Dingke; Yu Ping; Gao Kun; Zhai Renyou

    2007-01-01

    Objective: To evaluate the effect of PTBD in treating malignant biliary obstruction caused by hilar cholangiocarcinoma. Methods: We retrospectively analyzed the data of 103 patients(M:62,F:41)with malignant obstructive jaundice caused by hilar cholangiocarcinoma. After taking percutaneous transhepatic cholangiography, metallic stent or plastic external catheter or external-internal catheter for drainage was deployed and then followed up was undertaken with clinical and radiographic evaluation and laboratory. examination. Results: All patients went though PTBD successfully (100%). According to Bismuth classification, all 103 cases consisted of I type(N=30), II type (N=30), III type (N=26) and IV type (N=17). Thirty-nine cases were placed with 47 stents and 64 eases with drainage tubes. 4 cases installed two stems for bilateral drainage, 2 cases installed two stents because of long segmental strictures with stent in stent, 1 case was placed with three stents, and 3 cases installed stent and plastic catheter together. Sixty-four cases received plastic catheters in this series, 35 cases installed two or more catheters for bilateral drainage, 28 cases installed external and internal drainage catheters, 12 eases installed external drainage catheters, and 24 eases installed both of them. There were 17 patients involving incorporative infection before procedure, 13 cases cured after procedure, and 15 new patients got inflammation after procedure. 13 cases showed increase of amylase (from May, 2004), 8 eases had bloody bile drainage and 1 case with pyloric obstruction. Total serum bilirubin reduced from (386 ± 162) μmol/L to (161 ± 117) μmol/L, (P<0.01) short term curative effect was related with the type of hilar cholangiocarcinoma. The survival time was 186 days(median), and 1, 3, 6, 12 month survival rate were 89.9%, 75.3%, 59.6%, 16.9%, respectively. Conclusion: Percutaneous transhepatic bile drainage is a safe and effective palliative therapy of malignant

  11. Pleural fluid drainage: Percutaneous catheter drainage versus surgical chest tube drainage

    International Nuclear Information System (INIS)

    Illescas, F.F.; Reinhold, C.; Atri, M.; Bret, P.M.

    1987-01-01

    Over the past 4 years, 55 cases (one transudate, 28 exudates, and 26 empymas) were drained. Surgical chest tubes alone were used in 35 drainages, percutaneous catheters alone in five drainages, and both types in 15 drainages. Percutaneous catheter drainage was successful in 12 of 20 drainages (60%). Surgical tube drainage was successful in 18 of 50 drainages (36%). The success rate for the nonempyema group was 45% with both types of drainage. For the empyema group, the success rate for percutaneous catheter drainage was 66% vs 23% for surgical tube drainage. Seven major complications occurred with surgical tube drainage, but only one major complication occurred with percutaneous catheter drainage. Radiologically guided percutaneous catheter drainage should be the procedure of choice for pleural fluid drainage. It has a higher success rate for empyemas and is associated with less complications

  12. A simple method of using a Foley catheter to drain pleural effusion.

    Science.gov (United States)

    Ben-Nun, Alon; Best, Lael Anson

    2008-01-01

    Pleural effusion is a common problem, and various techniques of pleural fluid drainage have been described. We report our experience of using a Foley-type catheter to drain pleural effusion. After the injection of local anesthesia, the catheter is inserted, usually through the 7th intercostal space, with the patient sitting upright. The size of the catheter is selected according to the predicted fluid characteristics, and ranges from 18 to 24 F. Once the catheter is positioned in the pleural space, the balloon is inflated with diluted soluble contrast material and connected to a urine collection bag. During the last 10 years, we have used 3500 catheters for this purpose. The catheter site can be used as a port for various procedures, including needle biopsy of the parietal pleura, talc-slurry pleurodesis, and intra-pleural fibrinolysis. This method of pleural drainage is simple, reliable, and inexpensive.

  13. Predicting Success of Catheter Drainage in Infected Necrotizing Pancreatitis

    NARCIS (Netherlands)

    Hollemans, Robbert A.; Bollen, Thomas L.; van Brunschot, Sandra; Bakker, Olaf J.; Ahmed Ali, Usama; van Goor, Harry; Boermeester, Marja A.; Gooszen, Hein G.; Besselink, Marc G.; van Santvoort, Hjalmar C.

    2016-01-01

    At least 30% of patients with infected necrotizing pancreatitis are successfully treated with catheter drainage alone. It is currently not possible to predict which patients also need necrosectomy. We evaluated predictive factors for successful catheter drainage. This was a post hoc analysis of 130

  14. Long-term survival of skin allografts in mice treated with fractionated total lymphoid irradiation

    International Nuclear Information System (INIS)

    Slavin, S.; Strober, S.; Fuks, Z.; Kaplan, H.S.

    1976-01-01

    Treatment of recipient Balb/c mice with fractionated, high-dose total lymphoid irradiation, a procedure commonly used in the therapy of human malignant lymphomas, resulted in fivefold prolongation of the survival of C57BL/Ka skin allografts despite major histocompatibility differences between the strains (H-2/sup d/ and H-2/sup b/, respectively). Infusion of 10 7 (C57BL/Ka x Balb/c)F 1 bone marrow cells after total lymphoid irradiation further prolonged C57BL/Ka skin graft survival to more than 120 days. Total lymphoid irradiation may eventually prove useful in clinical organ transplantation

  15. Frequency of puncture holes in peritoneal dialysis catheters related to the beta cap adapter.

    Science.gov (United States)

    Ohashi, Yasushi; Kansal, Sheru; Schreiber, Martin

    2012-01-01

    Between November 2009 and September 2011, 12 patients (6 women, 6 men) undergoing continuous peritoneal dialysis (PD) or automated PD developed puncture-like holes in the PD catheter near the interface of the adapter with the superior aspect of the Silastic PD catheter The adapter is used to connect the PD catheter to the PD transfer set. Over the course of 23 months, the 12 patients presented to the PD unit with 19 separate instances of catheter holes, for an event rate of 0.23 holes per patient-year Data including socio-demographic information, PD modality, need for antibiotic treatment, event recurrence, infectious complications, and time from catheter placement were collected from patients whose catheters did and did not develop holes. We observed no differences between patients whose catheters developed holes and those whose catheters did not. The location of the individual holes suggested a relationship between the adapter and the catheter holes. The holes, which led to increased patient morbidity and costs, may be related to structural changes made in 2006 to the adapter.

  16. Real-time x-ray fluoroscopy-based catheter detection and tracking for cardiac electrophysiology interventions

    Energy Technology Data Exchange (ETDEWEB)

    Ma Yingliang; Housden, R. James; Razavi, Reza; Rhode, Kawal S. [Division of Imaging Sciences and Biomedical Engineering, King' s College London, London SE1 7EH (United Kingdom); Gogin, Nicolas; Cathier, Pascal [Medisys Research Group, Philips Healthcare, Paris 92156 (France); Gijsbers, Geert [Interventional X-ray, Philips Healthcare, Best 5680 DA (Netherlands); Cooklin, Michael; O' Neill, Mark; Gill, Jaswinder; Rinaldi, C. Aldo [Department of Cardiology, Guys and St. Thomas' Hospitals NHS Foundation Trust, London SE1 7EH (United Kingdom)

    2013-07-15

    Purpose: X-ray fluoroscopically guided cardiac electrophysiology (EP) procedures are commonly carried out to treat patients with arrhythmias. X-ray images have poor soft tissue contrast and, for this reason, overlay of a three-dimensional (3D) roadmap derived from preprocedural volumetric images can be used to add anatomical information. It is useful to know the position of the catheter electrodes relative to the cardiac anatomy, for example, to record ablation therapy locations during atrial fibrillation therapy. Also, the electrode positions of the coronary sinus (CS) catheter or lasso catheter can be used for road map motion correction.Methods: In this paper, the authors present a novel unified computational framework for image-based catheter detection and tracking without any user interaction. The proposed framework includes fast blob detection, shape-constrained searching and model-based detection. In addition, catheter tracking methods were designed based on the customized catheter models input from the detection method. Three real-time detection and tracking methods are derived from the computational framework to detect or track the three most common types of catheters in EP procedures: the ablation catheter, the CS catheter, and the lasso catheter. Since the proposed methods use the same blob detection method to extract key information from x-ray images, the ablation, CS, and lasso catheters can be detected and tracked simultaneously in real-time.Results: The catheter detection methods were tested on 105 different clinical fluoroscopy sequences taken from 31 clinical procedures. Two-dimensional (2D) detection errors of 0.50 {+-} 0.29, 0.92 {+-} 0.61, and 0.63 {+-} 0.45 mm as well as success rates of 99.4%, 97.2%, and 88.9% were achieved for the CS catheter, ablation catheter, and lasso catheter, respectively. With the tracking method, accuracies were increased to 0.45 {+-} 0.28, 0.64 {+-} 0.37, and 0.53 {+-} 0.38 mm and success rates increased to 100%, 99

  17. Increased survival with enzalutamide in prostate cancer after chemotherapy

    NARCIS (Netherlands)

    Scher, H.I.; Fizazi, K.; Saad, F.; Taplin, M.E.; Sternberg, C.N.; Miller, K.; de Wit, R.; Mulders, P.F.A.; Chi, K.N.; Shore, N.D.; Armstrong, A.J.; Flaig, T.W.; Flechon, A.; Mainwaring, P.; Fleming, M.; Hainsworth, J.D.; Hirmand, M.; Selby, B.; Seely, L.; Bono, J. De; Investigators, A.

    2012-01-01

    BACKGROUND: Enzalutamide (formerly called MDV3100) targets multiple steps in the androgen-receptor-signaling pathway, the major driver of prostate-cancer growth. We aimed to evaluate whether enzalutamide prolongs survival in men with castration-resistant prostate cancer after chemotherapy. METHODS:

  18. Scale-space for empty catheter segmentation in PCI fluoroscopic images.

    Science.gov (United States)

    Bacchuwar, Ketan; Cousty, Jean; Vaillant, Régis; Najman, Laurent

    2017-07-01

    In this article, we present a method for empty guiding catheter segmentation in fluoroscopic X-ray images. The guiding catheter, being a commonly visible landmark, its segmentation is an important and a difficult brick for Percutaneous Coronary Intervention (PCI) procedure modeling. In number of clinical situations, the catheter is empty and appears as a low contrasted structure with two parallel and partially disconnected edges. To segment it, we work on the level-set scale-space of image, the min tree, to extract curve blobs. We then propose a novel structural scale-space, a hierarchy built on these curve blobs. The deep connected component, i.e. the cluster of curve blobs on this hierarchy, that maximizes the likelihood to be an empty catheter is retained as final segmentation. We evaluate the performance of the algorithm on a database of 1250 fluoroscopic images from 6 patients. As a result, we obtain very good qualitative and quantitative segmentation performance, with mean precision and recall of 80.48 and 63.04% respectively. We develop a novel structural scale-space to segment a structured object, the empty catheter, in challenging situations where the information content is very sparse in the images. Fully-automatic empty catheter segmentation in X-ray fluoroscopic images is an important and preliminary step in PCI procedure modeling, as it aids in tagging the arrival and removal location of other interventional tools.

  19. Extraneural metastases of medulloblastoma: desmoplastic variants may have prolonged survival.

    Science.gov (United States)

    Young, Robert J; Khakoo, Yasmin; Yhu, Stephen; Wolden, Suzanne; De Braganca, Kevin C; Gilheeney, Stephen W; Dunkel, Ira J

    2015-04-01

    Extraneural metastases from CNS medulloblastoma are rare and poorly described. The purpose of this study is to describe the clinical and radiological characteristics of a large single institution series of patients with medulloblastoma who developed extraneural metastases. We retrospectively reviewed a departmental database over a 20 year period for all patients with medulloblastoma who developed extraneural metastases. Chart and imaging reviews were performed, and overall survival (OS) estimated by the Kaplan-Meier method. We found 14 patients with medulloblastoma and extraneural metastases. The median age at initial diagnosis was 16.3 years (range, 3.2-44.2), and the most common subtype was desmoplastic (n = 6, 42.9%). After initial gross total resection, most patients received radiation therapy alone (n = 10, 71.4%). Metastases to bone were most common (n = 11, 78.6%) followed by metastases to bone marrow (n = 6, 42.9%), usually to the spine. The median time from initial diagnosis to first extraneural metastasis was 1.5 years (range, 0.2-17.4), and the median OS from extraneural metastasis to death was 3.3 years (range, 0-18). The Kaplan-Meier estimate of 5 year OS from extraneural metastasis diagnosis was 40.0% (95% CI, 20.2-79.2). Extraneural metastases from medulloblastoma may rarely develop after initial diagnosis to involve bone and bone marrow. We found that desmoplastic variant extraneural tumors had longer survival than nondesmoplastic variants, suggesting that histopathological and more recent molecular subtyping have important roles in determining the prognosis of medulloblastoma patients. © 2014 Wiley Periodicals, Inc.

  20. Risk factors for peritoneal dialysis catheter failure in children ...

    African Journals Online (AJOL)

    Background Peritoneal dialysis catheter (PDC) failure still remains a common clinical problem in pediatric patients despite advancements in catheter placement and dialysis techniques. Our aim was to determine the risk factors that may lead to PDC failure, especially those factors that could be potentially modified to ...

  1. Encrusted and incarcerated urinary bladder catheter: what are the ...

    African Journals Online (AJOL)

    Urinary bladder catheter encrustations are known complications of long-term urinary catheterisation, which is commonly seen in clinical practice. These encrustations can impede deflation of the balloon and therefore cause problems in the removal of the catheter. The options in managing an encrusted and incarcerated ...

  2. Encrusted and incarcerated urinary bladder catheter: what are the ...

    African Journals Online (AJOL)

    2010-11-25

    Nov 25, 2010 ... cases of extraluminal encrusted urethral catheters. Extracorporeal shock wave lithotripsy (ESWL) has been utilised in the treatment of the bladder stones. Borrowing this principle, Kunzman et al. (12) has even used ESWL to fragment the stone-like encrustation over the retained Foley catheter balloon.

  3. Surface-Treated versus Untreated Large-Bore Catheters as Vascular Access in Hemodialysis and Apheresis Treatments

    Directory of Open Access Journals (Sweden)

    Rolf Bambauer

    2012-01-01

    Full Text Available Background. Catheter-related infections, thrombosis, and stenosis are among the most frequent complications associated with catheters, which are inserted in vessels. Surface treatment processes of the outer surface, such as ion-beam-assisted deposition, can be used to mitigate such complications. Methods. This retrospective study (1992–2007 evaluated silver-coated (54 patients and noncoated (105 patients implanted large-bore catheters used for extracorporeal detoxification. The catheters were inserted into the internal jugular or subclavian veins. After removal, the catheters were cultured for bacterial colonization using standard microbiologic assays. They also were examined using scanning electron microscope. Results. The silver coated catheters showed a tendency towards longer in situ time. The microbiologic examinations of the catheter tips were in both catheter types high positive, but not significant. Conclusion. The silver-coated catheters showed no significantly reduction in infection rate by evaluation of all collected data in this retrospective study. There was no association between both catheters in significantly reducing savings in treatment costs and in reducing patient discomfort. Other new developed catheter materials such as the microdomain-structured inner and outer surface are considered more biocompatible because they mimic the structure of natural biological surface.

  4. Percutaneous placement of peritoneal port-catheter in oncologic patients

    International Nuclear Information System (INIS)

    Orsi, Franco; Vigna, Paolo Della; Bonomo, Guido; Penco, Silvia; Lovati, Elena; Bellomi, Massimo

    2004-01-01

    The aim of this paper is to describe the technique of percutaneous ultrasound (US)-guided placement of a peritoneal port-catheter in an interventional radiological setting. Nineteen patients with peritoneal carcinomatosis were selected for intraperitoneal port-catheter placement in order to perform intracavitary receptor-immuno- or radio-immunotherapy with Ytrium-90. All the procedures were performed percutaneously under US and fluoro guidance; the insertion site for catheters was chosen according to abdominal conditions and US findings: all devices were implanted at the lower abdominal quadrants. All patients were followed up with CT and US according to the therapy protocol. The procedure was successfully completed in 15/19 patients, in 4 being contraindicated by peritoneal adhesions. No procedure-related complications and device occlusions during therapy were observed; one catheter displaced 7 months later the placement. In our experience, this procedure was feasible, reliable and easy to perform, allowing the correct administration of the planned intracavitary therapy. Peritoneal adhesions are the main limitation of peritoneal port placement. (orig.)

  5. Effective flow performances and dialysis doses delivered with permanent catheters: a 24-month comparative study of permanent catheters versus arterio-venous vascular accesses.

    Science.gov (United States)

    Canaud, Bernard; Leray-Moragues, Hélène; Kerkeni, Nadia; Bosc, Jean-Yves; Martin, Katja

    2002-07-01

    Permanent venous catheters have emerged as a long-term vascular access option for renal replacement therapy in end-stage renal disease patients. The design and venous location of catheter devices bear intrinsic flow limitations that may negatively affect the adequacy of dialysis and the patient outcome. There is limited data comparing the long-term dialysis adequacy delivered with permanent catheters vs arterio-venous vascular accesses (AVA). To explore this problem, we conducted a prospective 24-month trial comparing the flow performances and dialysis dose (Kt/Vdp) deliveries of both access options in a group of 42 haemodialysis patients during two study phases. During the first 12 months the patients completed a treatment period by means of permanent dual silicone catheters (DualKT). Then they were transferred to an AVA (40 native arterio-venous fistulas and two PTFE grafts) and monitored for an additional 12-month period. Assessments of flow adequacy and dialysis quantification were performed monthly. Dialysis adequacy was achieved in all cases. No patient had to be transferred prematurely to the AVA because of catheter failure. Three catheters had to be replaced due to bacteraemia in three patients. The mean effective blood flow rates achieved were 316+/-3.5 ml/min and 340+/-3.3 ml/min with DualKT and AVA, respectively, for a pre-set machine blood flow of 348+/-2.2 ml/min. Recirculation rates evaluated with the 'slow blood flow' method were 8.6+/-0.6 and 12.1+/-0.8% for DualKT and AVA using mean values of the solute markers urea and creatinine. Due to the possibility of a comparison veno-venous vs arterio-venous blood circulation, a corrected arterio-venous access recirculation could be derived from the difference between the two, which was around 3%. The blood flow resistance of the DualKT was slightly higher than with AVA as indicated by venous pressure differences. Kt/Vdp delivered was 1.37+/-0.02 and 1.45+/-0.02 with DualKT and AVA access respectively. The

  6. Randomized Controlled Trial Comparing Open Versus Laparoscopic Placement of a Peritoneal Dialysis Catheter and Outcomes: The CAPD I Trial.

    Science.gov (United States)

    van Laanen, Jorinde H H; Cornelis, Tom; Mees, Barend M; Litjens, Elisabeth J; van Loon, Magda M; Tordoir, Jan H M; Peppelenbosch, Arnoud G

    2018-01-01

    had a paramedian wound infection. In the laparoscopic group, 1 patient had a transient cardiac event, 1 patient had intraabdominal bleeding requiring reoperation, and 1 patient had fluid leakage that could be managed conservatively. The survival curve demonstrated a good long-term function of PD. This randomized controlled trial (RCT) comparing open vs laparoscopic placement of PD catheters demonstrates equal clinical success rates between the 2 techniques. Advanced laparoscopic techniques such as catheter fixation techniques and omentopexy might further improve clinical outcome. Copyright © 2018 International Society for Peritoneal Dialysis.

  7. Severe neutropenia at time of port insertion is not a risk factor for catheter-associated infections in children with acute lymphoblastic leukemia.

    Science.gov (United States)

    Junqueira, Beatriz L P; Connolly, Bairbre; Abla, Oussama; Tomlinson, George; Amaral, Joao G

    2010-09-15

    The objective of this study was to determine whether severe neutropenia on the day of port-a-catheter (PORT) insertion was a risk factor for catheter-associated infection (CAI) in children with acute lymphoblastic leukemia (ALL). This was a retrospective study of children with ALL who had a PORT insertion between January 2005 and August 2008. Early (≤ 30 days) and late (>30 days) postprocedure complications were reviewed. The length of follow-up ranged between 7 months and 42 months. In total, 192 PORTs were inserted in 179 children. There were 43 CAIs (22%), and the infection rate was 0.35 per 1000 catheter-days. The CAI rate (15%) in children who had severe neutropenia on the day of the procedure did not differ statistically from the CAI rate (24%) in children who did not have severe neutropenia (P = .137). Conversely, patients with severe neutropenia who had a CAI were more likely to have their PORT removed (P = .019). The most common organisms to cause catheter removal were coagulase-negative Staphylococcus and Staphylococcus aureus. Patients with high-risk ALL had a statistically significant higher incidence of late CAI than patients with standard-risk ALL (P = .012). Age (P = .272), positive blood culture preprocedure (P = 1.0), and dexamethasone use (P = .201) were not risk factors for CAI. Patients who had an early CAI did not have a greater chance of having a late CAI. The catheter infection-free survival rate at 1 year was 88.6%. The current results indicated that severe neutropenia on the day of PORT insertion does not increase the risk of CAI in children with ALL. © 2010 American Cancer Society.

  8. [Catheter-associated bloodstream infections: implementation of a new consensus protocol].

    Science.gov (United States)

    Urrea Ayala, M; Rozas Quesada, L

    2009-07-01

    Catheter-associated bloodstream infection is highly prevalent and often associated with fatal complications. Some studies have shown that applying preventive interventions could help to reduce and control this type of infection. To determine whether a new consensus protocol for the manipulation and maintenance of central venous catheters would decrease catheter-associated bloodstream infections (CA-BSIs) in paediatric patients. To evaluate its compliance in intensive care units. Prospective study in the paediatric (PICU) and neonatal (NICU) intensive cares units, haematology, oncology and hospital wards in a Maternal and Paediatric reference Hospital in Barcelona. The study period is divided into two periods: before (first semester) and after the start of the new protocol (second semester) in 2007. The most important changes have been the insertion of the hermetic connection in the proximal and distal site (between the line and the syringe) of the central venous catheter (CVC), the labelling of the medication line and the CVC with the date of placement. A check-list to evaluate compliance was introduced in both intensive care units (paediatrics and neonatal) during the second study period. The rates of bloodstream infection per 1000 catheter-days were assessed. The rate of bloodstream infections per 1000 catheter-days before and after the start of the new protocol was 5.7 and 4.9 in PICU; 24.6 and 18.0 in NICU; 7.6 and 4.6 in haematology-oncology, and 11.9 and 10.3 in hospital wards. As regards compliance to the protocol, we found that proximal sealed connectors were used in more than 95% of the cases and up to 85% of the central venous catheter were labelled with the insertion date in both intensive care units. A consensus protocol for the use and maintenance of central venous catheters and healthcare worker training helped to control the rate of CA-BSIs. We reaffirm the importance of epidemiological surveillance as a measure for controlling nosocomial infections.

  9. Vaginal extrusion of a ventriculo-peritoneal shunt catheter in an adult

    Directory of Open Access Journals (Sweden)

    Christopher M Bonfield

    2015-01-01

    Full Text Available Ventriculo-peritoneal shunts (VPS are commonly used in the treatment of various neurosurgical conditions, including hydrocephalus and pseudotumor cerebri. We report only the second case of vaginal extrusion of a VPS catheter in an adult, and the first case with a modern VPS silastic peritoneal catheter. A 45-year-old female with a history of VPS for pseudotumor cerebri, Behcet′s syndrome, and hysterectomy presented to our institution with the chief complaint of tubing protruding from her vagina after urination. On gynecologic examination, the patient was found to have approximately 15 cm of VPS catheter protruding from her vaginal apex. A computed tomography scan of the abdomen and shunt X-ray series demonstrated no breaks in the tubing, but also confirmed the finding of the VPS catheter extruding through the vaginal cuff into the vagina. The patient had the VPS removed and an external ventricular drain was placed for temporary cerebrospinal fluid diversion. Ventricular catheter cultures were positive for diphtheroids. After an appropriate course of antibiotics, a contralateral ventriculo-pleural shunt was placed one week later. Although vary rare, vaginal extrusion can occur in adults, even with modern VPS catheters.

  10. Expression of the costimulatory molecule B7-H3 is associated with prolonged survival in human pancreatic cancer

    International Nuclear Information System (INIS)

    Loos, Martin; Hedderich, Dennis M; Ottenhausen, Malte; Giese, Nathalia A; Laschinger, Melanie; Esposito, Irene; Kleeff, Jörg; Friess, Helmut

    2009-01-01

    Costimulatory signaling has been implicated as a potential regulator of antitumor immunity in various human cancers. In contrast to the negative prognostic value of aberrant B7-H1 expression by pancreatic cancer cells, the role of B7-H3 is still unknown. Therefore, we investigated the expression pattern and clinical significance of B7-H3 expression in human pancreatic cancer. B7-H3 expression was evaluated by immunohistochemistry in 68 patients with pancreatic cancer who underwent surgical tumor resection. Expression data was correlated with clinicopathologic features and with the number of tumor-infiltrating T cells. B7-H3 expression was significantly upregulated in pancreatic cancer compared to normal pancreas (p < 0.05). In 60 of 68 examined tumors B7-H3 protein was detectable in pancreatic cancer cells. Patients with high tumor B7-H3 levels had a significantly better postoperative prognosis than patients with low tumor B7-H3 levels (p = 0.0067). Furthermore, tumor B7-H3 expression significantly correlated with the number of tumor-infiltrating CD8+ T cells (p = 0.018). We demonstrate for the first time that B7-H3 is abundantly expressed in pancreatic cancer and that tumor-associated B7-H3 expression significantly correlates with prolonged postoperative survival. Our findings suggest that B7-H3 might play an important role as a potential stimulator of antitumor immune response in pancreatic cancer

  11. Double balloon esophageal catheter for diagnosis of tracheo-esophageal fistula

    International Nuclear Information System (INIS)

    Kiyan, Guersu; Dagli, Tolga E.; Tugtepe, Halil; Kodalli, Nihat

    2003-01-01

    Congenital H-type and recurrent tracheo-esophageal fistulas (TEF) are always difficult to diagnose. For a more accurate diagnosis we designed a new double balloon catheter, which is a modification of esophageal dilatation balloon. The catheter has two balloons to occlude the esophagus proximal and distal to the fistula. The fistula can be identified by passing of the contrast material to the tracheal tree, which was injected into the esophageal segment between the inflated balloons. To prove the efficiency of this catheter, a TEF was created surgically in a New Zealand rabbit. On the postoperative fourteenth day the catheter was tried and the fistula could be visualized easily by injecting the contrast material. We think this technique may be of use in the diagnosis of TEF in children. (orig.)

  12. Stabilization of a percutaneously implanted port catheter system for hepatic artery chemotherapy infusion

    International Nuclear Information System (INIS)

    Shindoh, Noboru; Ozaki, Yutaka; Kyogoku, Shinsuke; Yamana, Daigo; Sumi, Yukiharu; Katayama, Hitoshi

    1999-01-01

    A port catheter system for hepatic artery infusion chemotherapy was implanted percutaneously via the left subclavian artery in 41 patients for treatment of unresectable liver metastases. The catheter tip was inserted into the gastroduodenal artery (GDA), the end hole was occluded with a guidewire fragment, and a side-hole for infusion was positioned at the bifurcation of the proper hepatic artery and the GDA. The GDA was embolized with steel coils around the infusion catheter tip via a transfemoral catheter. This procedure is designed to reduce the incidence of hepatic artery occlusion and infusion catheter dislocation.

  13. Survival and Recovery of Phaeocystis Antarctica (Prymnesiophyceae) from Prolonged Darkness and Freezing

    Science.gov (United States)

    The colony-forming haptophyte Phaeocystis antarctica is an important primary producer in the Ross Sea, and must survive long periods of darkness and freezing in this extreme environment. We conducted experiments on the responses of P. antarctica-dominated phytoplankton assemblage...

  14. In Vitro Urethra Model to Characterize The Frictional Properties of Urinary Catheters

    DEFF Research Database (Denmark)

    Røn, Troels; Lee, Seunghwan

    2016-01-01

    conformal sliding contacts with the catheter and high relevance to clinical catherization. With the proposed urethra model assembled in texture analyzer, the lubricity of catheters lubricated in different modes was tested. In comparison with conventional pin-on-disk tribometry, the coefficients of friction......, frictional properties of tubular devices such as catheters, endoscopes, and angioplasty balloons are particularly challenging to characterize because of non-standard shape and contact configuration. In this study, we propose that fabrication of in vitro urethra model with castable elastomers can provide...... of sliding contacts with the urethra model with unlubricated and lubricated catheters were determined. Impact of the improved bio-relevance of friction testing methods on the evaluation of various catheter materials and surface modification methods is discussed in detail....

  15. Hydrophilic-coated catheter appreciation study in a pediatric population

    Science.gov (United States)

    Boucher, Andréanne; Cloutier, Jonathan; Lebel, Sylvie; Hamel, Micheline; Lamontagne, Pascale; Bolduc, Stéphane

    2010-01-01

    Objective: The objective of the paper was to compare the satisfaction of hydrophilic-coated catheters (HC) (SpeediCath, Coloplast Canada, Mississauga, ON) versus uncoated catheters in a pediatric neurogenic bladder population, in order to identify a target group for HC. The main hypothesis was that our patients, with regard to their limitations, might have difficulties using the HC. Material and methods: A comparative prospective study was initiated in one pediatric rehabilitation centre. Out of the 39 patients who tried the HC during a routine clinic visit, 31 patients/parents accepted to participate in a 1-week trial and to answer a satisfaction questionnaire. Their medical records were reviewed for age, neurological disease, intellectual deficit, impaired dexterity and method of catheterization (Mitrofanoff/urethra). Results: Thirty of the 31 patients answered the satisfaction questionnaire. The median age for the 30 patients was 13.5 years (range 6–20 years). Of these patients, 19 were females (63%), 26 performed self-catheterization (87%), and 6 had Mitrofanoff (20%). Ten children (33%) would be ready to proceed with HC and all 10 children would receive catheterization by the urethra. Of these, 9 were females (90%), 8 used compact-HC (80%) and all were self-sufficient. Patients using compact-HC would continue with this catheter. In the patient comments, males catheterizing per-urethra and patients using a continent stoma requiring long catheters had problems with the excess of lubricant. Conclusion: Most children preferred their usual uncoated catheter and would not change for HC. Female patients catheterizing per-urethra with a compact-HC seem to benefit most from this catheter. PMID:21749816

  16. A comparison between two types of central venous catheters in the prevention of catheter-related infections: the importance of performing all the relevant cultures

    NARCIS (Netherlands)

    van Vliet, J.; Leusink, J.A.; de Jongh, B.M.; de Boer, A.

    2001-01-01

    Objective: to determine the efficacy of double-lumen central venous catheters coated with chlorhexidine and silver-sulfadiazine in reducing the incidence of catheter-related infections. Design: a randomized controlled trial. Setting: medical-surgical intensive care unit of a 600-bed teaching

  17. Complications of Peripherally Inserted Central Venous Catheters: A Retrospective Cohort Study.

    Directory of Open Access Journals (Sweden)

    Paula Parás-Bravo

    Full Text Available The use of venous catheters is a widespread practice, especially in oncological and oncohematological units. The objective of this study was to evaluate the complications associated with peripherally inserted central catheters (PICCs in a cohort of patients.In this retrospective cohort study, we included all patient carrying PICCs (n = 603 inserted at our institute between October 2010 and December 2013. The main variables collected were medical diagnosis, catheter care, location, duration of catheterization, reasons for catheter removal, complications, and nursing care. Complications were classified as infection, thrombosis, phlebitis, migration, edema, and/or ecchymosis.All patients were treated according to the same "nursing care" protocol. The incidence rate of complications was two cases per 1000 days of catheter duration. The most relevant complications were infection and thrombosis, both with an incidence of 0.17 cases per 1000 days of the total catheterization period. The total average duration of catheterization was 170 days [SD 6.06]. Additionally to "end of treatment" (48.42% and "exitus", (22.53% the most frequent cause of removal was migration (displacement towards the exterior of the catheter (5.80%.PICCs are safe devices that allow the administration of long-term treatment and preserve the integrity of the venous system of the patient. Proper care of the catheter is very important to improve the quality life of patients with oncologic and hematologic conditions. Therefore, correct training of professionals and patients as well as following the latest scientific recommendations are particularly relevant.

  18. Decreasing dialysis catheter rates by creating a multidisciplinary dialysis access program.

    Science.gov (United States)

    Rosenberry, Patricia M; Niederhaus, Silke V; Schweitzer, Eugene J; Leeser, David B

    2018-03-01

    Centers for Medicare and Medicaid Services have determined that chronic dialysis units should have 45%. A multidisciplinary program was established with goals of decreasing catheter rates in order to decrease central line-associated bloodstream infections, decrease mortality associated with central line-associated bloodstream infection, decrease hospital days, and provide savings to the healthcare system. We collected the catheter rates within three dialysis centers served over a 5-year period. Using published data surrounding the incidence and related costs of central line-associated bloodstream infection and mortality per catheter day, the number of central line-associated bloodstream infection events, the costs, and the related mortality could be determined prior to and after the initiation of the dialysis access program. An organized dialysis access program resulted in a 82% decrease in the number of central venous catheter days which lead to a concurrent reduction in central line-associated bloodstream infection and deaths. As a result of creating an access program, central venous catheter rates decreased from an average rate of 45% to 8%. The cost savings related to the program was calculated to be over US$5 million. The decrease in the number of mortalities is estimated to be between 13 and 27 patients. We conclude that a formalized access program decreases catheter rates, central line-associated bloodstream infection, and the resultant hospitalizations, mortality, and costs. Areas with high hemodialysis catheter rates should develop access programs to better serve their patient population.

  19. Evaluation of two different epidural catheters in clinical practice. narrowing down the incidence of paresthesia!

    Science.gov (United States)

    Bouman, E A C; Gramke, H F; Wetzel, N; Vanderbroeck, T H T; Bruinsma, R; Theunissen, M; Kerkkamp, H E M; Marcus, M A E

    2007-01-01

    Although epidural anesthesia is considered safe, several complications may occur during puncture and insertion of a catheter. Incidences of paresthesia vary between 0.2 and 56%. A prospective, open, cohort-controlled pilot study was conducted in 188 patients, ASA I-III, age 19-87 years, scheduled for elective surgery and epidural anesthesia. We evaluated a 20 G polyamide (standard) catheter and a 20 G combined polyurethane-polyamide (new) catheter. Spontaneous reactions upon catheter-insertion, paresthesia on questioning, inadvertent dural or intravascular puncture, and reasons for early catheter removal were recorded. The incidence of paresthesia reported spontaneously was 21.3% with the standard catheter and 16.7% with the new catheter. Systematically asking for paresthesia almost doubled the paraesthesia rate. Intravascular cannulation occurred in 5%. No accidental dural punctures occurred. An overall incidence of 13.3% of technical problems led to early catheter removal. The new catheter was at least equivalent to the standard regarding epidural success rate and safety : rate of paresthesia, intravascular and dural cannulation.

  20. Real-time x-ray fluoroscopy-based catheter detection and tracking for cardiac electrophysiology interventions

    International Nuclear Information System (INIS)

    Ma Yingliang; Housden, R. James; Razavi, Reza; Rhode, Kawal S.; Gogin, Nicolas; Cathier, Pascal; Gijsbers, Geert; Cooklin, Michael; O'Neill, Mark; Gill, Jaswinder; Rinaldi, C. Aldo

    2013-01-01

    Purpose: X-ray fluoroscopically guided cardiac electrophysiology (EP) procedures are commonly carried out to treat patients with arrhythmias. X-ray images have poor soft tissue contrast and, for this reason, overlay of a three-dimensional (3D) roadmap derived from preprocedural volumetric images can be used to add anatomical information. It is useful to know the position of the catheter electrodes relative to the cardiac anatomy, for example, to record ablation therapy locations during atrial fibrillation therapy. Also, the electrode positions of the coronary sinus (CS) catheter or lasso catheter can be used for road map motion correction.Methods: In this paper, the authors present a novel unified computational framework for image-based catheter detection and tracking without any user interaction. The proposed framework includes fast blob detection, shape-constrained searching and model-based detection. In addition, catheter tracking methods were designed based on the customized catheter models input from the detection method. Three real-time detection and tracking methods are derived from the computational framework to detect or track the three most common types of catheters in EP procedures: the ablation catheter, the CS catheter, and the lasso catheter. Since the proposed methods use the same blob detection method to extract key information from x-ray images, the ablation, CS, and lasso catheters can be detected and tracked simultaneously in real-time.Results: The catheter detection methods were tested on 105 different clinical fluoroscopy sequences taken from 31 clinical procedures. Two-dimensional (2D) detection errors of 0.50 ± 0.29, 0.92 ± 0.61, and 0.63 ± 0.45 mm as well as success rates of 99.4%, 97.2%, and 88.9% were achieved for the CS catheter, ablation catheter, and lasso catheter, respectively. With the tracking method, accuracies were increased to 0.45 ± 0.28, 0.64 ± 0.37, and 0.53 ± 0.38 mm and success rates increased to 100%, 99.2%, and 96

  1. Influence of a transfusion of donor leukocytes treated with 8-methoxypsoralen and long-wave ultraviolet light (PUVA) on skin allograft survival in mice

    International Nuclear Information System (INIS)

    Gruner, S.; Noack, F.; Meffert, H.

    1989-01-01

    The influence of pretransplant donor spleen cell infusions on murine skin graft survival was studied. In dependence on the time interval between transplantation and transfusion an accelerated or delayed rejection of the grafts was observed. If the donor spleen cells were treated with the photosensitizer 8-methoxypsoralen and UVA light (PUVA) a graft prolongation was achieved at all time intervals. Furthermore, the survival of antigenically unrelated grafts was also prolonged. An additional immunosuppressive treatment of the recipients with antilymphocyte serum, but not cyclophosphamide, led to a further prolongation of graft survival. The survival of PUVA treated skin grafts was not longer in recipients preinfused with PUVA treated donor cells compared with untreated hosts. The results presented in this work may have implications in clinical organ transplantation to prevent sensitizing reactions by sparing protective mechanisms for the graft. (author)

  2. Discriminating Tissue Stiffness with a Haptic Catheter: Feeling the Inside of the Beating Heart.

    Science.gov (United States)

    Kesner, Samuel B; Howe, Robert D

    2011-01-01

    Catheter devices allow physicians to access the inside of the human body easily and painlessly through natural orifices and vessels. Although catheters allow for the delivery of fluids and drugs, the deployment of devices, and the acquisition of the measurements, they do not allow clinicians to assess the physical properties of tissue inside the body due to the tissue motion and transmission limitations of the catheter devices, including compliance, friction, and backlash. The goal of this research is to increase the tactile information available to physicians during catheter procedures by providing haptic feedback during palpation procedures. To accomplish this goal, we have developed the first motion compensated actuated catheter system that enables haptic perception of fast moving tissue structures. The actuated catheter is instrumented with a distal tip force sensor and a force feedback interface that allows users to adjust the position of the catheter while experiencing the forces on the catheter tip. The efficacy of this device and interface is evaluated through a psychophyisical study comparing how accurately users can differentiate various materials attached to a cardiac motion simulator using the haptic device and a conventional manual catheter. The results demonstrate that haptics improves a user's ability to differentiate material properties and decreases the total number of errors by 50% over the manual catheter system.

  3. The effects of sodium bicarbonate during prolonged cardiopulmonary resuscitation.

    Science.gov (United States)

    Weng, Yi-Ming; Wu, Shih-Hao; Li, Wen-Cheng; Kuo, Chan-Wei; Chen, Shou-Yen; Chen, Jih-Chang

    2013-03-01

    This study was performed to determine the effects of sodium bicarbonate injection during prolonged cardiopulmonary resuscitation (for >15 minutes). The retrospective cohort study consisted of adult patients who presented to the emergency department (ED) with the diagnosis of cardiac arrest in 2009. Data were retrieved from the institutional database. A total of 92 patients were enrolled in the study. Patients were divided into 2 groups based on whether they were treated (group1, n = 30) or not treated (group 2, n = 62) with sodium bicarbonate. There were no significant differences in demographic characteristics between groups. The median time interval between the administration of CPR and sodium bicarbonate injection was 36.0 minutes (IQR: 30.5-41.8 minutes). The median amount of bicarbonate injection was 100.2 mEq (IQR: 66.8-104.4). Patients who received a sodium bicarbonate injection during prolonged CPR had a higher percentage of return of spontaneous circulation, but not statistical significant (ROSC, 40.0% vs. 32.3%; P = .465). Sustained ROSC was achieved by 2 (6.7%) patients in the sodium bicarbonate treatment group, with no survival to discharge. No significant differences in vital signs after ROSC were detected between the 2 groups (heart rate, P = .124; systolic blood pressure, P = .094). Sodium bicarbonate injection during prolonged CPR was not associated with ROSC after adjust for variables by regression analysis (Table 3; P = .615; odds ratio, 1.270; 95% confidence interval: 0.501-3.219) The administration of sodium bicarbonate during prolonged CPR did not significantly improve the rate of ROSC in out-of-hospital cardiac arrest. Copyright © 2013 Elsevier Inc. All rights reserved.

  4. Fantoni’s Tracheostomy using Catheter High Frequency Jet Ventilation

    Directory of Open Access Journals (Sweden)

    P. Török

    2012-01-01

    Full Text Available Background: It has been shown previously that conventional ventilation delivered through a long cuffed endotracheal tube is associated with a high flow-resistance and frequent perioperative complications. Aim: We attempted to supersede the conventional ventilation by high-frequency jet ventilation through a catheter (HFJV-C and assess safety of the procedure. Material and methods: Using a translaryngeal tracheostomy kit, we performed a translaryngeal (Fantoni tracheostomy (TLT. Subsequently, we introduced a special 2-way prototype ventilatory catheter into the trachea via the TLT under bronchoscopic control. Satisfactory HFJV-C ventilation through the catheter was achieved in 218 patients. Results: There were no significant adverse effects on vital signs observed in the cohort during the study. The pH, SpO2, PaO2, and PaCO2 did not change significantly following the HFJV-C. The intrinsic PEEPi measured in trachea did not exceed 4—5 cm H2O during its application, which was significantly less than during the classical ventilation via the endotracheal tube fluctuating between 12 and 17 cm H2O. No serious medical complications occurred. Conclusion: The HFJV during Fantoni’s tracheostomy using the catheter HFJV-C proved to be a safe and effective method of lung ventilation at the intensive care unit. Key words: Translaryngeal tracheostomy, HFJV via catheter.

  5. A comparative analysis of radiological and surgical placement of central venous catheters

    International Nuclear Information System (INIS)

    McBride, Kieran D.; Fisher, Ross; Warnock, Neil; Winfield, David A.; Reed, Malcolm W.; Gaines, Peter A.

    1997-01-01

    Purpose. To compare the differences in practice and outcome of all radiologically and surgically placed central venous catheters retrospectively over a 2-year period simultaneously, at a single institution. Methods.A total of 253 Hickman catheters were inserted in 209 patients; 120 were placed radiologically in 102 patients and 133 were placed surgically in 107 patients. The indication was chemotherapy in 76% of radiological and in 47% of surgical cases; the remainder were for total parenteral nutrition and venous access. Results. There were 6 (4.5%) primary surgical failures and a further 17 (13%) surgical cases requiring multiple placement attempts. Pneumothorax occurred once (0.8%) surgically and four times (3.3%) radiologically. There were no radiological primary misplacements but there were five (3.7%) surgical ones. Catheter or central vein thrombosis occurred in four (3.3%) radiological and five (3.7%) surgical cases. The rate of infection per 1000 catheter-days was 1.9 in radiologically placed catheters and 4.0 in surgically placed ones (p<0.001). Average catheter life-span was similar for the two placement methods (100±23 days). Conclusion. Radiological placement is consistently more reliable than surgical placement. There are fewer placement complications and fewer catheter infections overall

  6. Catheter Displacement into Inferior Epigastric Vein Causing Local Phlebitis and Cellulitis

    Directory of Open Access Journals (Sweden)

    Noriko Hattori

    2012-01-01

    Full Text Available Catheter insertion for intravenous hyperalimentation is a commonly and widely used clinical technique. When compared with the incidence of complications associated with insertions into the internal jugular vein or the subclavian vein, complications associated with insertions into the femoral vein are less frequent. In this paper, we describe a very rare complication of femoral vein catheter insertion—namely, catheter displacement into the inferior epigastric vein.

  7. Evaluation of electrical nerve stimulation for epidural catheter positioning in the dog.

    Science.gov (United States)

    Garcia-Pereira, Fernando L; Sanders, Robert; Shih, Andre C; Sonea, Ioana M; Hauptman, Joseph G

    2013-09-01

    To evaluate the accuracy of epidural catheter placement at different levels of the spinal cord guided solely by electrical nerve stimulation and resultant segmental muscle contraction. Prospective, experiment. Six male and two female Beagles, age (1 ± 0.17 years) and weight (12.9 ± 1.1 kg). Animals were anesthetized with propofol and maintained with isoflurane. An insulated epidural needle was used to reach the lumbosacral epidural space. A Tsui epidural catheter was inserted and connected to a nerve stimulator (1.0 mA, 0.1 ms, 2 Hz) to assess positioning of the tip at specific spinal cord segments. The catheter was advanced to three different levels of the spinal cord: lumbar (L2-L5), thoracic (T5-T10) and cervical (C4-C6). Subcutaneous needles were previously placed at these spinal levels and the catheter was advanced to match the needle location, guided only by corresponding muscle contractions. Catheter position was verified by fluoroscopy. If catheter tip and needle were at the same vertebral body a score of zero was assigned. When catheter tip was cranial or caudal to the needle, positive or negative numbers, respectively, corresponding to the number of vertebrae between them, were assigned. The mean and standard deviation of the number of vertebrae between catheter tip and needle were calculated to assess accuracy. Results are given as mean ± SD. The catheter position in relation to the needle was within 0.3 ± 2.0 vertebral bodies. Positive predictive values (PPV) were 57%, 83% and 71% for lumbar, thoracic and cervical regions respectively. Overall PPV was 70%. No significant difference in PPV among regions was found. Placement of an epidural catheter at specific spinal levels using electrical nerve stimulation was feasible without radiographic assistance in dogs. Two vertebral bodies difference from the target site may be clinically acceptable when performing segmental epidural regional anesthesia. © 2013 Association of Veterinary

  8. Catheter-assisted retrieval of adhesive Geunther Tulip filter: preliminary experience

    International Nuclear Information System (INIS)

    Xiao Liang; Tong Jiajie; Xie Shiyang; Shen Jing

    2011-01-01

    Objective: To retrospectively summarize the technical experience in performing catheter-assisted retrieval of adhesive Geunther Tulip filter. Methods: During the period from November 2007 to October 2009, 95 patients with pulmonary embolism and acute deep vein thrombosis of lower limbs were admitted to authors' hospital. As simple snare technique failed to catch the adhesive Geunther Tulip filter previously implanted in inferior vena cava (IVC) in 6 patients (four males and two females with a mean age of 43.7 years), catheter-assisted retrieval of adhesive Geunther Tulip filter had to be carried out. The specific procedure was as follows. After phlebography of IVC confirmed that the filter's retrieval hook had adhered to IVC wall, the adhesion was separated with the help of catheter as well as goose-neck capturing device, then, the Geunther Tulip filter was retrieved. After the procedure, both anticoagulation and antibiotic medication were employed for 3-5 days. All the patients were followed up for 4-12 months. Vascular ultrasonography and pulmonary 3D CTA were re-examined in 6 months after primary operation. Results: All 6 adhesive Geunther Tulip filters were successfully removed with a success rate of 100%. The manipulation used in the procedure included catheter-twisting technique (n=1), catheter-looping technique (n=1) and catheter-snare looping technique (n=4). The mean operation time was 40.5 minutes (in the range of 17-78 minutes). The average filter-dwelling time was 46.7 days (ranging from 14 to 80 days). No thrombus formation in deep veins of lower extremity or pulmonary embolism occurred during the follow-up period. Conclusion: The catheter-assisted retrieval technique carries high retrieval rate for adhesive Geunther Tulip filter in IVC, it can markedly improve the retrieval success rate of Tulip IVC filter. (authors)

  9. The efficacy of Jackson drain in the application to be a tunnel pleural catheter (TPC) in the management of malignant pleural effusion.

    Science.gov (United States)

    Tscheikuna, Jamsak; Thomrongpairoj, Preecha; Disayabutr, Suppareurg

    2011-06-01

    Malignant pleural effusion (MPE) is a common clinical problem in patients with advanced cancer and portends a poor prognosis, which means survival of less than six months. In June 1997, the US-FDA approved an indwelling TPC with a one-way drainage valve to be used in the management of MPE. Although popularity of this TPC has increased over the past few years, the experience with this device remains limited in Thai patients. One of the reasons is its high cost. Assess the efficacy and the safety of customary indwelling TPC by using Jackson drain in the management of patients with symptomatic MPE. Ten patients with symptomatic MPE were receiving these catheters (18 Fr Silicone catheters with 25 cm fenestrated length) to drain effusion via plastic vacuum bottles (250 ml) every other day or as needed to relieve dyspnea. The patient's dyspnic respiration, quality of life, and comfort during the catheter's application were quantified with a Borg score, the St. George Respiratory Disease Questionnaire (SGRQ), and the comfort's score, respectively. These parameters were recorded at initial (before insertion) and 2-week follow-up visit. Pain after 24 hours of each insertion was quantified by visual pain analogue scale (VPAS). Patients were followed until either death or catheter removal. The Borg score, SGRQ, and comfort's score showed significant improvement at 2-week visit (p drain was effective in the treatment of MPE as a TPC without early complications.

  10. A system to use electromagnetic tracking for the quality assurance of brachytherapy catheter digitization

    Energy Technology Data Exchange (ETDEWEB)

    Damato, Antonio L., E-mail: adamato@lroc.harvard.edu; Viswanathan, Akila N.; Don, Sarah M.; Hansen, Jorgen L.; Cormack, Robert A. [Department of Radiation Oncology, Dana-Farber Cancer Institute/Brigham and Women’s Hospital, Boston, Massachusetts 02115 (United States)

    2014-10-15

    Purpose: To investigate the use of a system using electromagnetic tracking (EMT), post-processing and an error-detection algorithm for detecting errors and resolving uncertainties in high-dose-rate brachytherapy catheter digitization for treatment planning. Methods: EMT was used to localize 15 catheters inserted into a phantom using a stepwise acquisition technique. Five distinct acquisition experiments were performed. Noise associated with the acquisition was calculated. The dwell location configuration was extracted from the EMT data. A CT scan of the phantom was performed, and five distinct catheter digitization sessions were performed. No a priori registration of the CT scan coordinate system with the EMT coordinate system was performed. CT-based digitization was automatically extracted from the brachytherapy plan DICOM files (CT), and rigid registration was performed between EMT and CT dwell positions. EMT registration error was characterized in terms of the mean and maximum distance between corresponding EMT and CT dwell positions per catheter. An algorithm for error detection and identification was presented. Three types of errors were systematically simulated: swap of two catheter numbers, partial swap of catheter number identification for parts of the catheters (mix), and catheter-tip shift. Error-detection sensitivity (number of simulated scenarios correctly identified as containing an error/number of simulated scenarios containing an error) and specificity (number of scenarios correctly identified as not containing errors/number of correct scenarios) were calculated. Catheter identification sensitivity (number of catheters correctly identified as erroneous across all scenarios/number of erroneous catheters across all scenarios) and specificity (number of catheters correctly identified as correct across all scenarios/number of correct catheters across all scenarios) were calculated. The mean detected and identified shift was calculated. Results: The

  11. A system to use electromagnetic tracking for the quality assurance of brachytherapy catheter digitization

    International Nuclear Information System (INIS)

    Damato, Antonio L.; Viswanathan, Akila N.; Don, Sarah M.; Hansen, Jorgen L.; Cormack, Robert A.

    2014-01-01

    Purpose: To investigate the use of a system using electromagnetic tracking (EMT), post-processing and an error-detection algorithm for detecting errors and resolving uncertainties in high-dose-rate brachytherapy catheter digitization for treatment planning. Methods: EMT was used to localize 15 catheters inserted into a phantom using a stepwise acquisition technique. Five distinct acquisition experiments were performed. Noise associated with the acquisition was calculated. The dwell location configuration was extracted from the EMT data. A CT scan of the phantom was performed, and five distinct catheter digitization sessions were performed. No a priori registration of the CT scan coordinate system with the EMT coordinate system was performed. CT-based digitization was automatically extracted from the brachytherapy plan DICOM files (CT), and rigid registration was performed between EMT and CT dwell positions. EMT registration error was characterized in terms of the mean and maximum distance between corresponding EMT and CT dwell positions per catheter. An algorithm for error detection and identification was presented. Three types of errors were systematically simulated: swap of two catheter numbers, partial swap of catheter number identification for parts of the catheters (mix), and catheter-tip shift. Error-detection sensitivity (number of simulated scenarios correctly identified as containing an error/number of simulated scenarios containing an error) and specificity (number of scenarios correctly identified as not containing errors/number of correct scenarios) were calculated. Catheter identification sensitivity (number of catheters correctly identified as erroneous across all scenarios/number of erroneous catheters across all scenarios) and specificity (number of catheters correctly identified as correct across all scenarios/number of correct catheters across all scenarios) were calculated. The mean detected and identified shift was calculated. Results: The

  12. Unusual migration of ventriculo peritoneal distal catheter into vagina

    Directory of Open Access Journals (Sweden)

    Sghavamedin Tavallaee

    2015-04-01

    Full Text Available VP shunt is one of the most popular methods for ICP reduction and treatment of hydrocephalus. Various complications of this method are not uncommon such as shunt malfunction, infection and unusual migration of distal catheter. I present a case of migration of the peritoneal catheter out of the vagina.

  13. Successful treatment of central venous catheter induced superior vena cava syndrome with ultrasound accelerated catheter-directed thrombolysis.

    Science.gov (United States)

    Dumantepe, Mert; Tarhan, Arif; Ozler, Azmi

    2013-06-01

    Superior vena cava (SVC) syndrome results from obstruction of flow through the vessel either by external compression or thrombosis. External compression by intrathoracic neoplasms is the most common etiology, especially lung cancer and lymphoma. Thrombosis is becoming increasingly common due to the use of indwelling catheters and implantable central venous access devices. Most patients are unresponsive to anticoagulation alone which appears to be effective only in the mildest cases. However, recent advances in catheter-based interventions have led to the development of a variety of minimally invasive endovascular strategies to remove venous thrombus and accepted as an important first-line treatment given its high overall success rate and low morbidity as compared with medical and surgical treatments. Ultrasound accelerated catheter-directed thrombolysis (UACDT) has been developed to rapidly and completely resolve the existing thrombus. This technique integrates high frequency, low intensity ultrasound (US) with standard CDT in order to accelerate clot dissolution, reducing treatment time and the incidence of thrombolysis-related complications. An US wave enhances drug permeation through thrombus by disaggregating the fibrin matrix, exposing additional plasminogen receptor sites to the thrombolytic agent. The US energy affects thrombus in the entire venous segment, increasing the probability of complete thrombus clearing. We report the case of a 56-year-old man who presented with a 5 days history of SVC syndrome symptoms who had been receiving chemotherapy for colon cancer through a right subclavian vein port catheter. The patient successfully treated with UACDT with EkoSonic(®) Mach4e Endovascular device with an overnight infusion. © 2013 Wiley Periodicals, Inc. Copyright © 2013 Wiley Periodicals, Inc.

  14. Catheter-Related Bloodstream Infections in Adults Receiving Home Parenteral Nutrition

    DEFF Research Database (Denmark)

    Tribler, Siri; Brandt, Christopher F; Hvistendahl, Mark

    2018-01-01

    BACKGROUND: A common complication in patients receiving home parenteral nutrition (HPN) is catheter-related bloodstream infections (CRBSIs). The CRBSI incidence has been advocated as an outcome parameter assessing the quality of care. This study aimed to illustrate how the use of different CRBSI......) and European Society for Clinical Nutrition (ESPEN) CRBSI criteria. Employing a catheter-salvaging strategy, 40% of the CRBSI diagnoses were supported by the paired blood culture positivity criteria and only 6% by a positive catheter tip. In 53%, CRBSIs were categorized as a clinical or "probable CRBSI...

  15. Preprocedural ultrasound examination versus manual palpation for thoracic epidural catheter insertion

    Directory of Open Access Journals (Sweden)

    Ahmed M Hasanin

    2017-01-01

    Conclusion: Preprocedural ultrasound imaging increased the incidence of first pass success in thoracic epidural catheter insertion and reduced the catheter insertion time compared to manual palpation method.

  16. Treatment of lung abscess: effectiveness of percutaneous catheter drainage in 14 patients

    Energy Technology Data Exchange (ETDEWEB)

    Jeong, Su Hyun; Han, Young Min; Kim, Chong Soo; Chung, Gyung Ho; Ryu, Chun Su; Sohn, Myung Hee; Choi, Ki Chul [Chonbuk National University Medical School, Cheonju (Korea, Republic of)

    1995-01-15

    To evaluate the effectiveness of percutaneous catheter drainage in treatment of the lung abscess. We treated the lung abscesses in 14 patients (12 mean, 2 women), who did not respond to medical therapy, by percutaneous catheter drainage under fluoroscopic or ultrasound guidance. One abscess due to infacted bulla was managed by combination treatment with alcohol sclerosing therapy. Patients were followed by serial chest radiographs every three days and the amount of drained or aspirated pus evaluated. The treatment effect and recurrence were followed by chest PA and lateral chest at one week after removal of drainage catheter. Thirteen patients (93%) recovered clinically and radiologically within 3 days. In 10 patients, drainage catheter could be removed within 2 weeks, and three patients, the catheter was kept longer. Most complications were mild; vague to moderate chest pain (n = 14), mild hemoptysis (n = 2), and pneumothorax (n = 1). One man who suffered from far advanced pulmonary tuberculosis died of asphyxia caused by massive hemoptysis 16 days after percutaneous drainage. Percutaneous catheter drainage is a safe and effective method for treating lung abscess.

  17. Large-deflection statics analysis of active cardiac catheters through co-rotational modelling.

    Science.gov (United States)

    Peng Qi; Chen Qiu; Mehndiratta, Aadarsh; I-Ming Chen; Haoyong Yu

    2016-08-01

    This paper presents a co-rotational concept for large-deflection formulation of cardiac catheters. Using this approach, the catheter is first discretized with a number of equal length beam elements and nodes, and the rigid body motions of an individual beam element are separated from its deformations. Therefore, it is adequate for modelling arbitrarily large deflections of a catheter with linear elastic analysis at the local element level. A novel design of active cardiac catheter of 9 Fr in diameter at the beginning of the paper is proposed, which is based on the contra-rotating double helix patterns and is improved from the previous prototypes. The modelling section is followed by MATLAB simulations of various deflections when the catheter is exerted different types of loads. This proves the feasibility of the presented modelling approach. To the best knowledge of the authors, it is the first to utilize this methodology for large-deflection static analysis of the catheter, which will enable more accurate control of robot-assisted cardiac catheterization procedures. Future work would include further experimental validations.

  18. Catheter Migration After Implantationan Intrathecal Baclofen Infusion Pump for Severe Spasticity: A Case Report

    Directory of Open Access Journals (Sweden)

    Tung-Chou Li

    2008-09-01

    Full Text Available We report a case of intrathecal baclofen infusion pump implantation complicated by migration of the catheter tip. A 55-year-old man required an intrathecal baclofen infusion for severe spasticity 4 years after a cervical spinal cord injury with incomplete tetraparesis. Twelve months after initial implantation of the device, the patient began to experience a recurrence of trunk tightness and spasticity. Subsequent X-ray and computed tomography evaluations of the catheter system revealed pooling of contrast medium outside of the intrathecal distribution in the lumbar subcutaneous region of the back and therefore migration of the pump catheter tip. At surgical revision, emphasis was placed on minimizing the length of catheter outside of the spine and securing the catheter in the supraspinous fascia with a right-angled anchor. The distance between the anchors and the entry point of the catheter into the supraspinous fascia was also reduced to prevent slipping when the patient bends forward. After surgery, the patient's spasticity improved and, 1 year later, he has experienced no further complications during follow-up, requiring an average baclofen dose of 150 mg/day. Here, we describe several surgical methods intended to secure the intrathecal catheter and prevent catheter migration. Other complications related to catheter failure are also highlighted.

  19. Management of retained encrusted urethral catheter with extracorporeal shockwave lithotripsy

    Directory of Open Access Journals (Sweden)

    Sameh Anwar Kunzman

    2002-01-01

    Full Text Available We report a case of non-deflating heavily encrusted Foley catheter successfully removed by extracorporeal shockwave lithotripsy (ESWL. To our knowledge this is the first case of using ESWL to remove encrusted foley catheter retained in the bladder.

  20. Interventional radiologic placement of tunneled central venous catheters : results and complications in 557 cases

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Chan Kyo; Do, Young Soo; Paik, Chul H. [Samsung Medical Center, Sungkyunkwan Univ. School of Medicine, Seoul (Korea, Republic of)] (and others)

    1999-05-01

    To evaluate prospectively the results of interventional radiologic placement of tunneled central venous catheters, and subsequent complications. Between April 1997 and April 1998, a total of 557 tunneled central venous catheters were percutaneously placed in 517 consecutive patients in an interventional radiology suite. The indications were chemotherapy in 533 cases, total parenteral nutrition in 23 and transfusion in one. Complications were evaluated prospectively by means of a chart review, chest radiography, central vein angiography and blood/catheter culture. The technical success rate for tunneled central venous catheter placement was 100% (557/557 cases). The duration of catheter placement ranged from 4 to 356 (mean, 112{+-}4.6) days; Hickman catheters were removed in 252 cases during follow-up. Early complications included 3 cases of pneumothorax(0.5%), 4 cases of local bleeding/hematoma(0.7%), 2 cases of primary malposition(0.4%), and 1 case of catheter leakage(0.2%). Late complications included 42 cases of catheter-related infection(7.5%), 40 cases of venous thrombosis (7.2%), 18 cases of migration (3.2%), 5 cases of catheter / pericatheter of occlusion(0.8%), and 1 case of pseudoaneurysm(0.2%). The infection rate and thrombosis rate per 1000 days were 1.57 and 1.50, respectively. The technical success rate of interventional radiologic placement of tunneled central venous catheters was high. In comparison to conventional surgical placement, it is a more reliable method and leads to fewer complications.

  1. Catheter-Associated Urinary Tract Infections

    Science.gov (United States)

    ... Duodenoscope Sampling Method Interim Duodenoscope Culture Method Multiplex Real-Time PCR Detection of KPC & NDM-1 genes Quinolones ... The most commonly used external catheter is a soft flexible sheath that fits over the penis (“condom” ...

  2. Acceptance criteria for reprocessed AcuNav catheters: comparison between functionality testing and clinical image assessment.

    Science.gov (United States)

    Bank, Alan J; Berry, James M; Wilson, Robert F; Lester, Bruce R

    2009-03-01

    The AcuNav-catheter is a vector-phased array ultrasound catheter that has shown great utility for both diagnosis and electrophysiological interventions. To test the feasibility of limited catheter reuse and to ensure that reprocessed catheters would produce acceptable clinical images, the present study compared the 2-D and Doppler image quality, as determined by clinical assessment, with the catheter's functional status as determined by the FirstCall 2000 transducer tester. Reprocessed catheters from four functional categories, two acceptable and two unacceptable, were used to collect images, 2-D and Doppler, from a porcine heart. The images were blinded and then rated by clinical evaluation. The study found that catheter images from all functional categories were found to be clinically acceptable except for those from the lowest unacceptable category. In addition, examination of tip deflection characteristics showed no significant difference between new and reprocessed catheters. We conclude that reprocessed AcuNav catheters that pass functional tests are able to produce clinical images, 2-D and Doppler, which are equivalent to their new counterparts.

  3. Nature of the suppressor cells mediating prolonged graft survival after administration of extracted histocompatibility antigen and cyclosporine

    International Nuclear Information System (INIS)

    Yoshimura, N.; Kahan, B.D.

    1985-01-01

    Antigen-specific suppressor T cells are induced by donor histocompatibility antigen extracted from spleen cells with 3M KCl combined with cyclosporine (Ag-CsA). A single i.v. injection of 5 mg 3M-KCl-extracted donor Buffalo (Buf, RT1b) antigen (Ag) combined with a three day course of CsA prolonged renal allograft survival in Wistar-Furth (WFu, RT1u) hosts to a greater extent (MST 26.5 days) than CsA alone (MST 11.8 days). Peripheral blood lymphocytes (PBL) or spleen cells harvested from Ag-CsA-treated recipients ten days after transplantation inhibited the mixed lymphocyte reaction (MLR) between normal responder WFu cells and irradiated Buf cells (55.6% and 64.4% suppression, respectively, P less than 0.025), but not third-party Brown-Norway (BN, RT1n) stimulator cells (13.6% and -18.3% suppression, respectively, NS). The suppressor effect was not mediated by cytolytic cells; there was neither primary nor secondary cytolytic activity against 51 Cr-labeled Con-A blastoid Buf cells. The suppressor cells were neither adherent to plastic dishes nor to nylon-wool columns. PBL irradiated with 800 rads, but not 1500 rads, suppressed the MLR. A single injection of cyclophosphamide (CY, 25 mg/kg) seven days after transplantation abrogated the suppression induced by Ag-CsA treatment. Moreover, PBL from Ag-CsA recipients failed to suppress the MLR, if depleted either of all T cells by treatment with monoclonal antibody (Mab) W3/13 HLK (pan T cells; % suppression -15.8), or of cytotoxic/suppressor cells with Mab OX-8 (-19.3% suppression) together with rabbit antimouse immunoglobulin and complement

  4. The technical development of steerable catheter robot in performing interventional vascular surgery

    International Nuclear Information System (INIS)

    He Zhixiu; Qian Wei; Song Chengli

    2011-01-01

    Minimally invasive surgery is one of the primary means for the treatment of vascular diseases. The catheter is one of the main operating tools. As the vascular system is quite complicated and tiny, it is usually very difficult for the operator to accurately and bare-handily accomplish the whole intravascular procedure. Therefore, with the rapid development of minimally invasive surgeries the practical study related to the clinical employment of steerable catheter robot has attracted the researchers' attention. This paper aims to describe the emergence and development history of steerable catheter robot and also to introduce the main achievements as well as the up-to-date progress in the researches relevant to steerable catheter robot that the have been obtained by research workers all over the world so far. The prospects for the future development of steerable catheter robot are briefly discussed. (authors)

  5. Anatomical characteristics of pulmonary veins for the prediction of postoperative recurrence after radiofrequency catheter ablation of atrial fibrillation.

    Directory of Open Access Journals (Sweden)

    Wei Wei

    Full Text Available BACKGROUND: The relationship between focal pulmonary vein potential and atrial fibrillation (AF has been confirmed. Pulmonary vein (PV isolation and circumferential pulmonary vein ablation have been the most commonly used procedures of radiofrequency ablation. However, few studies have investigated the relationship between anatomical characteristics of PV and AF recurrences after radiofrequency ablation. METHODOLOGY: For 267 AF patients treated by radiofrequency catheter ablation, the anatomic structure characteristics of pulmonary veins were assessed by multi-slice spiral computed tomography while the values of left atrial diameter (LAD were measured with transesophageal ultrasonic cardiogram. After radiofrequency catheter ablation, postoperative recurrence was evaluated during a 10-month term follow-up. PRINCIPAL FINDINGS: During follow-up, postoperative recurrence occurred in 44 patients. The mean diameters of LAD, left superior PV, right superior PV, all left PV, and all superior PV were significantly larger in patients with postoperative recurrence (Recurrence vs. Non-recurrence group; 43.9 ± 6.4 mm vs. 40.7 ± 5.6 mm; 18.4 ± 2.1 mm vs. 17.1 ± 3.1 mm; 18.2 ± 2.8 mm vs. 17.2 mm ± 3.9 mm; 16.4 ± 1.5 mm vs. 15.6 ± 2.5 mm; 18.3 ± 2.1 mm vs. 17.1 ± 3.0 mm; respectively; all P < 0.05. Multivariable survival analysis showed that the type and the course of AF, LAD, and the diameters of all superior PV were the independent risk factors for the postoperative recurrence after radiofrequency catheter ablation. CONCLUSIONS: The enlargements of all superior PV and LAD, long course of diseases, and persistent AF were the independent risk factors for the postoperative recurrence after radiofrequency catheter ablation.

  6. Nursing care for patients carrying indwelling catheter in target vessel for continuous chemotherapy

    International Nuclear Information System (INIS)

    Wen Lihong

    2009-01-01

    Objective: To reduce the occurrence of undesirable catheter-related events in patients with indwelling catheter during the course of continuous chemotherapy. Methods: (1)To enhance the propaganda,education and guidance to patients. (2) To standardize the nursing care operations. (3) To establish the reasonable care rules and procedures. (4) The nurses should take the daily nursing care,observations and recording work seriously. Results: Through the analysis of a variety of problems occurred in patients with indwelling catheter during the course of continuous chemotherapy the nursing care experience was summed up. Conclusion: Proper and effective care can reduce the occurrence of undesirable catheter-related events in patients with indwelling catheter during the course of continuous chemotherapy. (authors)

  7. Laparoscopic versus open peritoneal dialysis catheter insertion, the LOCI-trial: a study protocol

    Directory of Open Access Journals (Sweden)

    Hagen Sander M

    2011-12-01

    Full Text Available Abstract Background Peritoneal dialysis (PD is an effective treatment for end-stage renal disease. It allows patients more freedom to perform daily activities compared to haemodialysis. Key to successful PD is the presence of a well-functioning dialysis catheter. Several complications, such as in- and outflow obstruction, peritonitis, exit-site infections, leakage and migration, can lead to catheter removal and loss of peritoneal access. Currently, different surgical techniques are in practice for PD-catheter placement. The type of insertion technique used may greatly influence the occurrence of complications. In the literature, up to 35% catheter failure has been described when using the open technique and only 13% for the laparoscopic technique. However, a well-designed randomized controlled trial is lacking. Methods/Design The LOCI-trial is a multi-center randomized controlled, single-blind trial (pilot. The study compares the laparoscopic with the open technique for PD catheter insertion. The primary objective is to determine the optimum placement technique in order to minimize the incidence of catheter malfunction at 6 weeks postoperatively. Secondary objectives are to determine the best approach to optimize catheter function and to study the quality of life at 6 months postoperatively comparing the two operative techniques. Discussion This study will generate evidence on any benefits of laparoscopic versus open PD catheter insertion. Trial registration Dutch Trial Register NTR2878

  8. Cerebral microdialysis methodology--evaluation of 20 kDa and 100 kDa catheters.

    Science.gov (United States)

    Hutchinson, P J; O'Connell, M T; Nortje, J; Smith, P; Al-Rawi, P G; Gupta, A K; Menon, D K; Pickard, J D

    2005-08-01

    Microdialysis monitoring of cerebral metabolism is now performed in several neuro-intensive care units. Conventional microdialysis utilizes CMA70 catheters with 20 kDa molecular weight cut-off membranes enabling the measurement of small molecules such as glucose, lactate, pyruvate and glutamate. The CMA71 100 kDa molecular weight cut-off microdialysis catheter has recently been introduced to allow detection of larger molecules such as cytokines. The objective of this study was to perform in vitro and in vivo testing of the CMA71 microdialysis catheter, comparing its performance with the CMA70. In vitro comparison studies of three of each catheter using reference analyte solutions, demonstrated equivalent recovery for glucose, lactate, pyruvate and glutamate (range 94-97% for CMA70 and 88-103% for CMA71). In vivo comparison involved intracranial placement of paired CMA70 and CMA71 catheters (through the same cranial access device) in six patients with severe traumatic brain injury. Both catheters were perfused with CNS Perfusion Fluid without dextran at 0.3 microl min-1 with hourly sampling and bedside analysis on a CMA600 microdialysis analyser. The two catheters yielded equivalent results for glucose, lactate, pyruvate, glutamate and lactate/pyruvate ratio. CMA71 microdialysis catheters can, therefore, be used for routine clinical monitoring of extracellular substances, as well as for their intended research role of larger molecular weight protein sampling.

  9. Reducing catheter-associated urinary tract infections: a quality-improvement initiative.

    Science.gov (United States)

    Davis, Katherine Finn; Colebaugh, Ann M; Eithun, Benjamin L; Klieger, Sarah B; Meredith, Dennis J; Plachter, Natalie; Sammons, Julia Shaklee; Thompson, Allison; Coffin, Susan E

    2014-09-01

    Catheter-associated urinary tract infections (CAUTIs) are among the most common health care-associated infections in the United States, yet little is known about the prevention and epidemiology of pediatric CAUTIs. An observational study was conducted to assess the impact of a CAUTI quality improvement prevention bundle that included institution-wide standardization of and training on urinary catheter insertion and maintenance practices, daily review of catheter necessity, and rapid review of all CAUTIs. Poisson regression was used to determine the impact of the bundle on CAUTI rates. A retrospective cohort study was performed to describe the epidemiology of incident pediatric CAUTIs at a tertiary care children's hospital over a 3-year period (June 2009 to June 2012). Implementation of the CAUTI prevention bundle was associated with a 50% reduction in the mean monthly CAUTI rate (95% confidence interval: -1.28 to -0.12; P = .02) from 5.41 to 2.49 per 1000 catheter-days. The median monthly catheter utilization ratio remained unchanged; ∼90% of patients had an indication for urinary catheterization. Forty-four patients experienced 57 CAUTIs over the study period. Most patients with CAUTIs were female (75%), received care in the pediatric or cardiac ICUs (70%), and had at least 1 complex chronic condition (98%). Nearly 90% of patients who developed a CAUTI had a recognized indication for initial catheter placement. CAUTI is a common pediatric health care-associated infection. Implementation of a prevention bundle can significantly reduce CAUTI rates in children. Copyright © 2014 by the American Academy of Pediatrics.

  10. Peripheral intravenous catheter-related phlebitis and related risk factors.

    Science.gov (United States)

    Nassaji-Zavareh, M; Ghorbani, R

    2007-08-01

    Peripheral intravenous catheter-related phlebitis is a common and significant problem in clinical practice. This study aims to investigate the incidence of phlebitis and to evaluate some important related factors. 300 patients admitted to medical and surgical wards of hospitals in Semnan, Iran from April 2003 to February 2004 were prospectively studied. Variables evaluated were age, gender, site and size of catheter, type of insertion and underlying conditions (diabetes mellitus, trauma, infectious disease and burns). Phlebitis was defined when at least four criteria were fulfilled (erythema, pain, tenderness, warmth, induration, palpable cord and swelling). Any patient who was discharged or their catheter removed before three days were excluded. Phlebitis occurred in 26 percent (95 percent confidence interval [CI] 21- 31 percent) of patients. There was no significant relationship between age, catheter bore size, trauma and phlebitis. Related risk factors were gender (odds-ratio [OR] 1.50, 95 percent CI 1.01-2.22), site (OR 3.25, 95 percent CI 2.26-4.67) and type of insertion (OR 2.04, 95 percent CI 1.36-3.05) of catheter, diabetes mellitus (OR 7.78, 95 percent CI 4.59-13.21), infectious disease (OR 6.21, 95 percent CI 4.27-9.03) and burns (OR 3.96, 95 percent CI 3.26-4.82). Phlebitis is still an important and ongoing problem in medical practice. In patients with diabetes mellitus and infectious diseases, more attention is needed.

  11. Fluoroscopy guided percutaneous catheter drainage of pneumothorax in good mid-term patency with tube drainage

    International Nuclear Information System (INIS)

    Park, Ga Young; Oh, Joo Hyung; Yoon, Yup; Sung, Dong Wook

    1995-01-01

    To evaluate efficacy and the safety of percutaneous catheter drainage in patients with pneumothorax that is difficult to treat with closed thoracotomy. We retrospectively reviewed effectiveness of percutaneous catheter drainage (PCD) in 10 patients with pneumothorax. The catheter was inserted under fluoroscopic guidance. Seven patients had spontaneous pneumothorax caused by tuberculosis (n =4), reptured bullae (n = 2), and histiocytosis-X (n = 1). Three patients had iatrogenic pneumothorax caused by trauma (n = 1) and surgery (n = 2). All procedures were performed by modified Seldinger's method by using 8F-20F catheter. All catheter were inserted successfully. In 9 of 10 patients, the procedure was curative without further therapy. Duration of catheter insertion ranged from 1 day to 26 days. In the remaining 1 patient in whom multiple pneumothorax occurred after operation, catheter insertion was performed twice. Percutaneous catheter drainage under fluoroscopic guidance is effective and safe procedure for treatment of pneumothorax in patients with failed closed thoracotomy

  12. Fluoroscopy guided percutaneous catheter drainage of pneumothorax in good mid-term patency with tube drainage

    Energy Technology Data Exchange (ETDEWEB)

    Park, Ga Young; Oh, Joo Hyung; Yoon, Yup; Sung, Dong Wook [Kyung Hee University Hospital, Seoul (Korea, Republic of)

    1995-10-15

    To evaluate efficacy and the safety of percutaneous catheter drainage in patients with pneumothorax that is difficult to treat with closed thoracotomy. We retrospectively reviewed effectiveness of percutaneous catheter drainage (PCD) in 10 patients with pneumothorax. The catheter was inserted under fluoroscopic guidance. Seven patients had spontaneous pneumothorax caused by tuberculosis (n =4), reptured bullae (n = 2), and histiocytosis-X (n = 1). Three patients had iatrogenic pneumothorax caused by trauma (n = 1) and surgery (n = 2). All procedures were performed by modified Seldinger's method by using 8F-20F catheter. All catheter were inserted successfully. In 9 of 10 patients, the procedure was curative without further therapy. Duration of catheter insertion ranged from 1 day to 26 days. In the remaining 1 patient in whom multiple pneumothorax occurred after operation, catheter insertion was performed twice. Percutaneous catheter drainage under fluoroscopic guidance is effective and safe procedure for treatment of pneumothorax in patients with failed closed thoracotomy.

  13. Virulence factors in Proteus bacteria from biofilm communities of catheter-associated urinary tract infections.

    Science.gov (United States)

    Hola, Veronika; Peroutkova, Tereza; Ruzicka, Filip

    2012-07-01

    More than 40% of nosocomial infections are those of the urinary tract, most of these occurring in catheterized patients. Bacterial colonization of the urinary tract and catheters results not only in infection, but also various complications, such as blockage of catheters with crystalline deposits of bacterial origin, generation of gravels and pyelonephritis. The diversity of the biofilm microbial community increases with duration of catheter emplacement. One of the most important pathogens in this regard is Proteus mirabilis. The aims of this study were to identify and assess particular virulence factors present in catheter-associated urinary tract infection (CAUTI) isolates, their correlation and linkages: three types of motility (swarming, swimming and twitching), the ability to swarm over urinary catheters, biofilm production in two types of media, urease production and adherence of bacterial cells to various types of urinary tract catheters. We examined 102 CAUTI isolates and 50 isolates taken from stool samples of healthy people. Among the microorganisms isolated from urinary catheters, significant differences were found in biofilm-forming ability and the swarming motility. In comparison with the control group, the microorganisms isolated from urinary catheters showed a wider spectrum of virulence factors. The virulence factors (twitching motility, swimming motility, swarming over various types of catheters and biofilm formation) were also more intensively expressed. © 2012 Federation of European Microbiological Societies. Published by Blackwell Publishing Ltd. All rights reserved.

  14. Policies for replacing long-term indwelling urinary catheters in adults.

    Science.gov (United States)

    Cooper, Fergus P M; Alexander, Cameron Edwin; Sinha, Sanjay; Omar, Muhammad Imran

    2016-07-26

    Long-term indwelling catheters are used commonly in people with lower urinary tract problems in home, hospital and specialised health-care settings. There are many potential complications and adverse effects associated with long-term catheter use. The effect of health-care policies related to the replacement of long-term urinary catheters on patient outcomes is unclear. To determine the effectiveness of different policies for replacing long-term indwelling urinary catheters in adults. We searched the Cochrane Incontinence Specialised Trials Register, which contains trials identified from the Cochrane Central Register of Controlled Trials (CENTRAL), MEDLINE, MEDLINE In-Process, MEDLINE Epub Ahead of Print, CINAHL, ClinicalTrials.gov, WHO ICTRP and handsearching of journals and conference proceedings (searched 19 May 2016), and the reference lists of relevant articles. All randomised controlled trials investigating policies for replacing long-term indwelling urinary catheters in adults were included. At least two review authors independently performed data extraction and assessed risk of bias of all the included trials. Quality of evidence was assessed by adopting the GRADE approach. Any discrepancies were resolved by discussion between the review authors or an independent arbitrator. We contacted the authors of included trials to seek clarification where required. Three trials met the inclusion criteria, with a total of 107 participants in three different health-care settings: A USA veterans administration nursing home; a geriatric centre in Israel; and a community nursing service in Hong Kong. Data were available for three of the pre-stated comparisons. Priefer and colleagues evaluated different time intervals between catheter replacement (n = 17); Firestein and colleagues evaluated the use of antibiotic prophylaxis at the time of replacement (n = 70); and Cheung and colleagues compared two different types of cleaning solutions (n = 20).All the included trials were

  15. Pancreas tumor interstitial pressure catheter measurement

    Science.gov (United States)

    Nieskoski, Michael D.; Gunn, Jason; Marra, Kayla; Trembly, B. Stuart; Pogue, Brian W.

    2016-03-01

    This paper highlights the methodology in measuring interstitial pressure in pancreatic adenocarcinoma tumors. A Millar Mikrotip pressure catheter (SPR-671) was used in this study and a system was built to amplify and filter the output signal for data collection. The Millar pressure catheter was calibrated prior to each experiment in a water column at 37°C, range of 0 to 60 inH2O (112 mmHg), resulting in a calibration factor of 33 mV / 1 inH2O. The interstitial pressures measured in two orthotopically grown pancreatic adenocarcinoma tumor were 57 mmHg and 48 mmHg, respectively. Verteporfin uptake into the pancreatic adenocarcinoma tumor was measured using a probe-based experimental dosimeter.

  16. Radiographic assessment of venous catheter position in children: Value of the lateral view

    International Nuclear Information System (INIS)

    Stark, D.D.; Brasch, R.C.; Gooding, C.A.

    1984-01-01

    Frontal chest radiographs can be misleading in the evaluation of central venous catheter placement. Lateral chest radiographs were obtained, in addition to the standard frontal radiographs, in 25 young children. In five (20%) of the children, the catheters were found to be malpositioned, and the frontal radiograph showed evidence of the abnormality in all five. The lateral radiographs also showed evidence of the abnormality in all five children; however, in three of the five, the lateral radiographs provided additional, more specific, diagnostic information. The lateral chest radiographs also demonstrated satisfactory catheter positioning in three other children in whom the frontal radiographs suggested abnormal positioning. Accurate assessment of catheter position was possible in all patients using both frontal and lateral chest radiographs. Injection of contrast material was not necessary to locate malpositioned catheters. Lateral radiographs are recommended whenever an abnormal catheter position is suspected clinically or from findings on the routine frontal radiograph. (orig.)

  17. A 10-Fr ultrasound catheter with integrated micromotor for 4-D intracardiac echocardiography.

    Science.gov (United States)

    Lee, Warren; Griffin, Weston; Wildes, Douglas; Buckley, Donald; Topka, Terry; Chodakauskas, Thaddeus; Langer, Mark; Calisti, Serge; Bergstøl, Svein; Malacrida, Jean-Pierre; Lanteri, Frédéric; Maffre, Jennifer; McDaniel, Ben; Shivkumar, Kalyanam; Cummings, Jennifer; Callans, David; Silvestry, Frank; Packer, Douglas

    2011-07-01

    We developed prototype real-time 3-D intracardiac echocardiography catheters with integrated micromotors, allowing internal oscillation of a low-profile 64-element, 6.2-MHz phased-array transducer in the elevation direction. Components were designed to facilitate rotation of the array, including a low-torque flexible transducer interconnect and miniature fixtures for the transducer and micromotor. The catheter tip prototypes were integrated with two-way deflectable 10-Fr catheters and used in in vivo animal testing at multiple facilities. The 4-D ICE catheters were capable of imaging a 90° azimuth by up to 180° elevation field of view. Volume rates ranged from 1 vol/sec (180° elevation) to approximately 10 vol/sec (60° elevation). We successfully imaged electrophysiology catheters, atrial septal puncture procedures, and detailed cardiac anatomy. The elevation oscillation enabled 3-D visualization of devices and anatomy, providing new clinical information and perspective not possible with current 2-D imaging catheters.

  18. NURSING CARE IN PATIENTS NEONATES WITH PERIPHERALLY INSERTED CENTRAL CATHETER

    Directory of Open Access Journals (Sweden)

    Anacilda Oliveira Vieira

    2013-12-01

    Full Text Available Introduction: The PICC (peripherally inserted central catheter is a long flexible catheter which is inserted through a peripheral vein, progresses through a needle introducer until the final portion of the vena cava, acquiring characteristics of a central catheter. Objective: To point out the main theoretical and scientific ideas that demonstrate the reliability, competence and ability of nurses to perform the PICC. Methodology: Systematic review of articles, which were found by searching the database scientific journals and bibliographies area. Results: The success of integration depends on the patient assessment and choice of venous access where the catheter will be positioned, and its tip should be in the middle third of the superior vena cava, or the middle third of the inferior vena cava. In neonates, which are used more frequently, proper positioning of the catheter is through nursing care in making the dressing, and the first 24 hours it should be compressive. Ideally, the PICC remains in the vein for periods longer than seven days or until the end of treatment, thus decreasing invasive procedures. Conclusion: According to the Federal Board of Nursing (COFEN, it is lawful for the insertion of PICC nurses, provided it has undergone professional training.

  19. A survey of the use of arterial catheters in anesthetized dogs and cats: 267 cases.

    Science.gov (United States)

    Trim, Cynthia M; Hofmeister, Erik H; Quandt, Jane E; Shepard, Molly K

    2017-01-01

    To describe the clinical practice of insertion of arterial catheters in anesthetized dogs and cats, to document complications of arterial catheterization, and to determine risk factors associated with the complications. Prospective clinical study and retrospective evaluation of medical records. University teaching hospital. Dogs (n = 251) and 13 cats anesthetized for clinical procedures with arterial catheters inserted for blood pressure monitoring. None. Details of the animal and catheter were collected at the time of anesthesia. On the following day, the catheter site was palpated and observed for abnormalities and the medical records of all animals were reviewed retrospectively for complications. Details of catheter placement were available for 216 catheters: 158 catheters in a dorsal pedal artery, 50 catheters in the median caudal (coccygeal) artery, 6 in the median artery, and 1 each in a cranial tibial and lingual artery. Blood pressure was obtained from 200 catheters, and 12 catheters failed before the end of anesthesia. Postoperative observational data obtained from 112 catheters described a palpable arterial pulse at 73 sites and no pulse at 21 sites. No risk factor for arterial occlusion was identified. No complications resulting from arterial catheterization were noted in the medical records. Arterial catheterization resulted in loss of a peripheral pulse postoperatively in 21/94 (22.3%) of animals examined, although no evidence of tissue ischemia was noted in the medical records of any of the patients in this study. These results suggest that insertion of a catheter in the dorsal pedal or coccygeal arteries was not associated with a high risk for complications. However, the course of arterial occlusion postoperatively warrants further investigation. © Veterinary Emergency and Critical Care Society 2016.

  20. Adherence of staphylococcus aureus to catheter tubing inhibition by quaternary ammonium compounds.

    Science.gov (United States)

    Iyamba, Jean-Marie Liesse; Okombe, Daniel Tassa; Zakanda, Francis Nsimba; Malongo, Trésor Kimbeni; Unya, Joseph Welo; Lukukula, Cyprien Mbundu; Kikuni, Ntondo Za Balega Takaisi

    2016-01-01

    S. aureus is a Gram positive bacterium which is responsible for a wide range of infections. This pathogen has also the ability to adhere to biotic or abiotic surface such as central venous catheter (CVC) and to produce a biofilm. The aim of this study was to evaluate the effect of hexadecyltrimethyl ammonium bromide (HTAB) and Hexadecylbetainate chloride (HBC) on Staphylococcus aureus adherence to the catheter tubing and on bacteria growth. Broth microdilution method was used to determine the Minimal Inhibitory Concentration (MIC). The detection of slime production was done by Congo Red Agar method, and the adherence of bacteria to the catheter tubing was evaluated by the enumeration of bacteria on plate counts. The results of this study showed that the MICs of HTAB were ranged from 0.125 to 0.5 µg/mL, and those of HBC fluctuated between 2 to 8 µg/mL. HTAB and HBC inhibited bacteria adhesion on the surface of the catheter tubing. This study showed that HTAB and HBC can prevent the adherence of S. aureus strains to the surface of catheter tubing, suggesting that they could be used to prevent the risk of catheter related bloodstream infections.

  1. Echocardiography-guided Radiofrequency Catheter Ablation of Atrioventricular Node and VVI Pacemaker Implantation

    Directory of Open Access Journals (Sweden)

    T Guo

    2014-05-01

    Full Text Available Objective: This study is to evaluate the feasibility and safety of intracardiac radiofrequency catheter ablation (RFCA of the atrioventricular node (AVN and pacemaker implantation using transthoracic echocardiography. Methods: Eleven patients – six males and five females (mean age 66 years – with persistent or permanent atrial fibrillation/atrial flutter received RFCA of AVN and VVI pacemaker implantation (paces and senses the ventricle and is inhibited if it senses ventricular activity. Under transthoracic echocardiography, the electrode catheters were positioned intracardiac, and target ablation was performed, with the permanent pacemaking catheter in the left subclavian vein and the ablation catheter in the right femoral vein. The multi-view imaging and dynamic observation applied during the stable AV dissociation were successful. Results: Atrioventricular node ablation and permanent pacemaker implantation in 11 patients were completed successfully without X-ray exposure. The operation success rate was 100%. All patients recovered well within the follow-up period. Conclusions: Radiofrequency catheter ablation of AVN and VVI pacemaker implantation under transthoracic echocardiography guidance is a safe, easy and feasible approach. This procedure could be an important supplemental measure to catheter ablation of arrhythmia under routine X-ray fluoroscopy.

  2. Biofilm formation in long-term central venous catheters in children with cancer

    DEFF Research Database (Denmark)

    Handrup, Mette Møller; Fuursted, Kurt; Funch, Peter

    2012-01-01

    Taurolidine has demonstrated inhibition of biofilm formation in vitro. The aim of this study was to compare the effect of catheter locking with taurolidine vs heparin in biofilm formation in central venous catheters. Forty-eight children with cancer were randomized to catheter locking by heparin (n...... = 22) or taurolidine (n = 26), respectively. After removal, catheters were examined by standardized scanning electron microscopy to assess quantitative biofilm formation. Biofilm was present if morphologically typical structures and bacterial cells were identified. Quantitative and semi...... in the intraluminal biofilm formation and the rate of bacterial colonization detected by scanning electron microscopy in the two groups....

  3. Booted selective internal radiation therapy (B-SIRT) using 90Y-loaded glass microspheres induces prolonged overall survival for PVT patients

    International Nuclear Information System (INIS)

    Garin, E.; Lenoir, L.; Edeline, J.; Laffont, S.; Mesbah, H.; Poree, P.; Boucher, E.; Rolland, Y.

    2015-01-01

    Full text of publication follows. Goal: evaluation of the response rate and survival of hepatocellular carcinoma PVT patients treated with Therasphere using the boost concept. Material and methods: Therasphere was administered in 40 PVT hepatocellular carcinoma patients (main = 11, lobar = 23, segmental = 6). MAA SPECT/CT quantitative analysis was used for the calculation of the tumour dose (TD), the healthy injected liver dose (HLD) and the injected liver dose (LD). Response was evaluated at 3 months using EASL criterion. OS was evaluated using Kaplan and Meyer tests. Results: Mean 90 Y-loaded microspheres injected activity was 3.1 ± 1.5 GBq. Mean LD was 143 ± 49 Gy. Median TD was 316 Gy for responding lesions versus 133 Gy for non responding lesion (p<0.0001). With a threshold TD of 205 Gy, MAA-SPECT/CT was predictive of response with a sensibility of 100%, and an overall accuracy of 90% (0FN, 4FP). Knowing the TD and the HLD, 40% of the patients received an intensification of the treatment (increase of the injected activity with the goal to achieve a TD> 205 Gy with a LD > 150 Gy and a HLD<120 Gy) with a good response rate (81%) and without increased liver grade III toxicity (6.2% as against 12.5% in the non boosted patients, ns). 6 patients were put aside, 5 received a lobar hepatectomy. Median OS was 18.2 months [12-27]. It was 4 m [12-27] for patients with a TD < 205 Gy versus 21.5 m [12-28.5] for patients with a TD > 205 Gy. OS was 12 m [3-∞] for patients with main PVT versus 21.5 m [12-28.7] for patients segmental or lobar PVT (ns). Finally Os was 23.2 m for patients with a TD > 205 Gy and a good PVT targeting (n = 34). Conclusion: boosted selective internal radiation therapy using 90 Y-loaded glass microspheres induces prolonged overall survival for PVT patients without increasing liver toxicity. (authors)

  4. Transhepatic venous catheters for hemodialysis

    Directory of Open Access Journals (Sweden)

    Mohamed El Gharib

    2014-06-01

    Conclusion: Based on our findings, transhepatic hemodialysis catheters have proven to achieve good long-term functionality. A high level of maintenance is required to preserve patency, although this approach provides remarkably durable access for patients who have otherwise exhausted access options.

  5. Effects of drought and prolonged winter on Townsend's ground squirrel demography in shrubsteppe habitats

    Science.gov (United States)

    Van Horne, Beatrice; Olson, Gail S.; Schooley, Robert L.; Corn, Janelle G.; Burnham, Kenneth P.

    1997-01-01

    During a mark–recapture study of Townsend's ground squirrels (Spermophilus townsendii) on 20 sites in the Snake River Birds of Prey National Conservation Area, Idaho, in 1991 through 1994, 4407 animals were marked in 17639 capture events. This study of differences in population dynamics of Townsend's ground squirrels among habitats spanned a drought near the extreme of the 130-yr record, followed by prolonged winter conditions.Townsend's ground squirrels have a short active season (≈4 mo) in which to reproduce and store fat for overwintering. Their food consists largely of succulent grasses and forbs in this dry shrubsteppe and grassland habitat. The drought in the latter half of the 1992 active season produced early drying of Sandberg's bluegrass (Poa secunda) and was associated with low adult and juvenile body masses prior to immergence into estivation/hibernation. The following prolonged winter was associated with late emergence of females in 1993. Early-season body masses of adults were low in 1993 relative to 1992, whereas percentage of body fat in males was relatively high. These weather patterns in spring 1992 and winter 1993 also resulted in reduced adult persistence through the ≈7-mo inactive period, especially for adult females, and near-zero persistence of >1200 juveniles. Consequently, densities of Townsend's ground squirrels across the 20 livetrap sites declined.The demographic effects of drought and prolonged winter lasted at least through the subsequent breeding season. Adult females that survived these weather extremes produced fewer emergent young per female than did adult females prior to the event. Prior to the drought/prolonged winter, yearling female body masses were higher than, or indistinguishable from, those of adults. Females produced in 1993 had lower body masses as yearlings than did adult females.Demographic response to the drought and prolonged winter varied with habitat; ground squirrels in sagebrush habitat showed less decline

  6. Left septal atrial tachycardia after open-heart surgery: relevance to surgical approach, anatomical and electrophysiological characteristics associated with catheter ablation, and procedural outcomes.

    Science.gov (United States)

    Adachi, Toru; Yoshida, Kentaro; Takeyasu, Noriyuki; Masuda, Keita; Sekiguchi, Yukio; Sato, Akira; Tada, Hiroshi; Nogami, Akihiko; Aonuma, Kazutaka

    2015-02-01

    Septal atrial tachycardia (AT) can occur in patients without structural heart disease and in patients with previous catheter ablation of atrial fibrillation. We aimed to assess septal AT that occurs after open-heart surgery. This study comprised 20 consecutive patients undergoing catheter ablation of macroreentrant AT after open-heart surgery. Relevance to surgical approach, mechanisms, anatomic and electrophysiological characteristics, and outcomes were assessed. Septal AT was identified in 7 patients who had all undergone mitral valve surgery. All septal ATs were localized in the left atrial septum, whereas 10 of 13 nonseptal ATs originated from the right atrium. Patients with left septal AT had a thicker fossa ovalis (median, 4.0; 25th-75th percentile, 3.6-4.2 versus 2.3; 1.6-2.6 mm; P=0.006) and broader area of low voltage (open-heart surgery was characterized by a thicker septum, more scar burden in the septum, and repeated prolongations of the tachycardia cycle length during ablation. Such an arrhythmogenic substrate may interfere with transmural lesion formation by ablation and may account for higher likelihood of recurrence of left septal AT. © 2014 American Heart Association, Inc.

  7. Evaluation of the safety of latrogenic lntestinal perforation during placement of percutaneous drainage catheter in rabbit

    International Nuclear Information System (INIS)

    Lee, Choon Hyeong; Oh, Joo Hyung; Park, Ga Young; Shin, Hong Sub; Kim, In Sub; Yoon, Yup; Lee, Dong Ho; Ko, Young Tae; Choi, Woo Suk; Lim, Joo Won

    1996-01-01

    To evaluate the safety of transgression of the bowel during intraperitoneal percutaneous catheter placement in an animal model. Eight 8-F straight catheters were percutaneously inserted into the small and large bowel of eight rabbits. In four animals, the catheters were left in place until autopsy, whereas in the remaining four, the catheters were withdrawn five days after insertion. Autopsy was performed in all animals ten days after catheter placement, and gross and microscopic examination was carried out. Transgressing the bowel during intraperitoneal percutaneous catheter placement did not contribute to any clinically significant complications. At autopsy, there was no bowel leakage, peritonitis, or abscess, although peritoneal adhesions were found around the catheter tract. Although further study is warranted, our study with an animal model indicated that transgression of the intestine during percutaneous placement of an intraabdominal catheter did not produce significant complications

  8. Evaluation of the safety of latrogenic lntestinal perforation during placement of percutaneous drainage catheter in rabbit

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Choon Hyeong; Oh, Joo Hyung; Park, Ga Young; Shin, Hong Sub; Kim, In Sub; Yoon, Yup; Lee, Dong Ho; Ko, Young Tae; Choi, Woo Suk; Lim, Joo Won [Kyunghee Univ. Hospital, Seoul (Korea, Republic of)

    1996-10-01

    To evaluate the safety of transgression of the bowel during intraperitoneal percutaneous catheter placement in an animal model. Eight 8-F straight catheters were percutaneously inserted into the small and large bowel of eight rabbits. In four animals, the catheters were left in place until autopsy, whereas in the remaining four, the catheters were withdrawn five days after insertion. Autopsy was performed in all animals ten days after catheter placement, and gross and microscopic examination was carried out. Transgressing the bowel during intraperitoneal percutaneous catheter placement did not contribute to any clinically significant complications. At autopsy, there was no bowel leakage, peritonitis, or abscess, although peritoneal adhesions were found around the catheter tract. Although further study is warranted, our study with an animal model indicated that transgression of the intestine during percutaneous placement of an intraabdominal catheter did not produce significant complications.

  9. Ultrasound as a Screening Tool for Central Venous Catheter Positioning and Exclusion of Pneumothorax.

    Science.gov (United States)

    Amir, Rabia; Knio, Ziyad O; Mahmood, Feroze; Oren-Grinberg, Achikam; Leibowitz, Akiva; Bose, Ruma; Shaefi, Shahzad; Mitchell, John D; Ahmed, Muneeb; Bardia, Amit; Talmor, Daniel; Matyal, Robina

    2017-07-01

    Although real-time ultrasound guidance during central venous catheter insertion has become a standard of care, postinsertion chest radiograph remains the gold standard to confirm central venous catheter tip position and rule out associated lung complications like pneumothorax. We hypothesize that a combination of transthoracic echocardiography and lung ultrasound is noninferior to chest radiograph when used to accurately assess central venous catheter positioning and screen for pneumothorax. All operating rooms and surgical and trauma ICUs at the institution. Single-center, prospective noninferiority study. Patients receiving ultrasound-guided subclavian or internal jugular central venous catheters. During ultrasound-guided central venous catheter placement, correct positioning of central venous catheter was accomplished by real-time visualization of the guide wire and positive right atrial swirl sign using the subcostal four-chamber view. After insertion, pneumothorax was ruled out by the presence of lung sliding and seashore sign on M-mode. Data analysis was done for 137 patients. Chest radiograph ruled out pneumothorax in 137 of 137 patients (100%). Lung ultrasound was performed in 123 of 137 patients and successfully screened for pneumothorax in 123 of 123 (100%). Chest radiograph approximated accurate catheter tip position in 136 of 137 patients (99.3%). Adequate subcostal four-chamber views could not be obtained in 13 patients. Accurate positioning of central venous catheter with ultrasound was then confirmed in 121 of 124 patients (97.6%) as described previously. Transthoracic echocardiography and lung ultrasound are noninferior to chest x-ray for screening of pneumothorax and accurate central venous catheter positioning. Thus, the point of care use of ultrasound can reduce central venous catheter insertion to use time, exposure to radiation, and improve patient safety.

  10. Assessment of right liver graft perfusion effectiveness between one and two-catheter infusion methods.

    Science.gov (United States)

    Jung, Bo-Hyun; Hwang, Shin; Ha, Tae-Yong; Song, Gi-Won; Jung, Dong-Hwan; Kim, Ki-Hun; Ahn, Chul-Soo; Moon, Deok-Bog; Park, Gil-Chun; Kang, Sung-Hwa; Yoon, Young-In; Lee, Sung-Gyu

    2014-05-01

    Conventional graft perfusion method using one small-caliber catheter takes a relatively long time for right liver graft perfusion, thus some modification is needed. In this study, we intended to assess the effectiveness of right liver graft perfusion methods through comparison of different infusion catheters. The study consisted of two parts including one bench experiment to obtain data of hydraulic infusion and one clinical trial of 40 cases on graft perfusion with one- versus two-catheter infusion methods. These two graft infusion methods were compared in terms of the perfusion time and washing-out efficiency. At bench experiment, the infusion flow rate and infusion pressure were 3.3 ml/sec and 1.9 cmH20 in one blood transfusion catheter group, and 11.7 ml/sec and 3.1 cmH20 in single transurethral resection of prostate irrigation catheter group, and 6.6 ml/sec and 2.0 cmH20 in two blood transfusion catheters group, respectively. In clinical trial with 40 right liver grafts, two-catheter group had a shorter graft portal perfusion time for the first 2 L of histidine-tryptophan-ketoglutarate (HTK) solution than the conventional one-catheter group (375±25 seconds vs. 662±34 seconds; p=0.001) and a lower rate of incomplete blood washing-out after the initial 2 L portal perfusion (40% vs. 85%; p=0.03). The two-catheter infusion method appears to be more effective than the conventional one-catheter infusion method for right liver graft perfusion at the back table. Large size of right liver grafts seems to be its good indication.

  11. Inhibition and Inactivation of Uropathogenic Escherichia coli Biofilms on Urinary Catheters by Sodium Selenite

    Directory of Open Access Journals (Sweden)

    Amoolya Narayanan

    2018-06-01

    Full Text Available Urinary tract infections (UTI are the most common hospital-acquired infections in humans and are caused primarily by uropathogenic Escherichia coli (UPEC. Indwelling urinary catheters become encrusted with UPEC biofilms that are resistant to common antibiotics, resulting in chronic infections. Therefore, it is important to control UPEC biofilms on catheters to reduce the risk for UTIs. This study investigated the efficacy of selenium for inhibiting and inactivating UPEC biofilms on urinary catheters. Urinary catheters were inoculated with UPEC and treated with 0 and 35 mM selenium at 37 °C for 5 days for the biofilm inhibition assay. In addition, catheters with preformed UPEC biofilms were treated with 0, 45, 60, and 85 mM selenium and incubated at 37 °C. Biofilm-associated UPEC counts on catheters were enumerated on days 0, 1, 3, and 5 of incubation. Additionally, the effect of selenium on exopolysacchride (EPS production and expression of UPEC biofilm-associated genes was evaluated. Selenium at 35 mM concentration was effective in preventing UPEC biofilm formation on catheters compared to controls (p < 0.05. Further, this inhibitory effect was associated with a reduction in EPS production and UPEC gene expression. Moreover, at higher concentrations, selenium was effective in inactivating preformed UPEC biofilms on catheters as early as day 3 of incubation. Results suggest that selenium could be potentially used in the control of UPEC biofilms on urinary catheters.

  12. Ultrasound-guided pigtail catheters for drainage of various pleural diseases.

    Science.gov (United States)

    Liu, Yi-Heng; Lin, Yu-Chao; Liang, Shinn-Jye; Tu, Chih-Yen; Chen, Chia-Hung; Chen, Hung-Jen; Chen, Wei; Shih, Chuen-Ming; Hsu, Wu-Huei

    2010-10-01

    Little is known about the efficacy and safety of ultrasound-guided pigtail catheters for the management of various pleural diseases in the emergency department, ward, and intensive care unit. We conducted a retrospective study in a university hospital during a 1-year interval. A total of 276 patients (178 men and 98 women) underwent 332 pigtail catheters (the drain size ranged from 10F to 16F) under ultrasound guidance. The mean ± SEM patient age was 59 ± 18 years, and mean duration of drainage was 6.1 ± 2 days. A total of 64 drains (19.2%) were inserted for pneumothoraces; 98 drains (29.5%), for malignant effusions; 119 drains (35.8%), for parapneumonic effusions/empyemas; and 38 drains (11.4%), for massive transudate pleural effusions. The overall success rate was 72.9%. The success rate was highest when the drain was used to treat massive transudate effusions (81.6%) and malignant pleural effusions (75.5%), followed by parapneumonic effusions/empyemas (72.2%), hemothoraces (66.6%), and pneumothoraces (64.0%). Only 10 (3.0%) drains had complications due to the procedure, including infection (n = 4, 1.2%), dislodgment (n = 4, 1.2%), wound bleeding at the pigtail catheter puncture area complicated with hemothoraces (n = 1, 0.3%), and lung puncture (n = 1, 0.3%). There was no significant difference in success rate when different catheter sizes were used to treat pleural diseases. Ultrasound-guided pigtail catheters provide a safe and effective method of draining various pleural diseases. We strongly suggest that ultrasound-guided pigtail catheters be considered as the initial draining method for a variety of pleural diseases. Copyright © 2010 Elsevier Inc. All rights reserved.

  13. Transparent polyurethane film as an intravenous catheter dressing. A meta-analysis of the infection risks.

    Science.gov (United States)

    Hoffmann, K K; Weber, D J; Samsa, G P; Rutala, W A

    1992-04-15

    To obtain a quantitative estimate of the impact on infectious complications of using transparent dressings with intravenous catheters. Meta-analysis of all studies published in the English literature, including abstracts, letters, and reports that examined the primary research question of infection risks associated with transparent compared with gauze dressings for use on central and peripheral venous catheters. Studies were identified by use of the MEDLINE database using the indexing terms occlusive dressings, transparent dressings, and infection and by review of referenced bibliographies. Seven of the 15 studies (47%) of central venous catheters and seven of 12 studies (58%) of peripheral catheters met our inclusion criteria for analysis. All studies used a prospective cohort design, utilized hospitalized patients, and reported at least one of our defined outcomes. Data for each study were abstracted independently by three investigators. At least three studies were used in the analysis of each outcome. Applying a Mantel-Haenszel chi 2 analysis, use of transparent dressings on central venous catheters was significantly associated with an elevated relative risk (RR) of catheter tip infection (RR = 1.78; 95% confidence interval [CI], 1.38 to 2.30). Catheter-related sepsis (RR = 1.69; 95% CI, 0.97 to 2.95) and bacteremia (RR = 1.63; 95% CI, 0.76 to 3.47) were both associated with an elevated RR. Use of transparent dressings on peripheral catheters was associated with an elevated RR of catheter-tip infection (RR = 1.53; 95% CI, 1.18 to 1.99) but not phlebitis (RR = 1.02; 95% CI, 0.86 to 1.20), infiltration (RR = 1.12; 95% CI, 0.92 to 1.37), or skin colonization (RR = 0.99; 95% CI, 0.90 to 1.09). The results demonstrated a significantly increased risk of catheter-tip infection with the use of transparent compared with gauze dressings when used with either central or peripheral catheters. An increased risk of bacteremia and catheter sepsis associated with the use of

  14. Regulatory dendritic cell infusion prolongs kidney allograft survival in nonhuman primates.

    Science.gov (United States)

    Ezzelarab, M B; Zahorchak, A F; Lu, L; Morelli, A E; Chalasani, G; Demetris, A J; Lakkis, F G; Wijkstrom, M; Murase, N; Humar, A; Shapiro, R; Cooper, D K C; Thomson, A W

    2013-08-01

    We examined the influence of regulatory dendritic cells (DCreg), generated from cytokine-mobilized donor blood monocytes in vitamin D3 and IL-10, on renal allograft survival in a clinically relevant rhesus macaque model. DCreg expressed low MHC class II and costimulatory molecules, but comparatively high levels of programmed death ligand-1 (B7-H1), and were resistant to pro-inflammatory cytokine-induced maturation. They were infused intravenously (3.5-10 × 10(6) /kg), together with the B7-CD28 costimulation blocking agent CTLA4Ig, 7 days before renal transplantation. CTLA4Ig was given for up to 8 weeks and rapamycin, started on Day -2, was maintained with tapering of blood levels until full withdrawal at 6 months. Median graft survival time was 39.5 days in control monkeys (no DC infusion; n = 6) and 113.5 days (p DCreg-treated animals (n = 6). No adverse events were associated with DCreg infusion, and there was no evidence of induction of host sensitization based on circulating donor-specific alloantibody levels. Immunologic monitoring also revealed regulation of donor-reactive memory CD95(+) T cells and reduced memory/regulatory T cell ratios in DCreg-treated monkeys compared with controls. Termination allograft histology showed moderate combined T cell- and Ab-mediated rejection in both groups. These findings justify further preclinical evaluation of DCreg therapy and their therapeutic potential in organ transplantation. © Copyright 2013 The American Society of Transplantation and the American Society of Transplant Surgeons.

  15. CHANGES IN PHYSIOLOGICAL TREMOR RESULTING FROM SLEEP DEPRIVATION UNDER CONDITIONS OF INCREASING FATIGUE DURING PROLONGED MILITARY TRAINING

    OpenAIRE

    A. Tomczak; J. Gajewski; J Mazur–Różycka

    2015-01-01

    The aim of the study was to define the changes of the characteristics of physiological postural tremor under conditions of increasing fatigue and lack of sleep during prolonged military training (survival).The subjects of the study were 15 students of the Polish Air Force Academy in Dęblin. The average age was 19.9±1.3 years. During the 36-hour-long continuous military training (survival) the subjects were deprived of sleep. Four tremor measurements were carried out for each of the subjects: ...

  16. Frequency of colonization and isolated bacteria from the tip of epidural catheter implanted for postoperative analgesia.

    Science.gov (United States)

    Stabille, Débora Miranda Diogo; Diogo Filho, Augusto; Mandim, Beatriz Lemos da Silva; de Araújo, Lúcio Borges; Mesquita, Priscila Miranda Diogo; Jorge, Miguel Tanús

    2015-01-01

    The increased use of epidural analgesia with catheter leads to the need to demonstrate the safety of this method and know the incidence of catheter colonization, inserted postoperatively for epidural analgesia, and the bacteria responsible for this colonization. From November 2011 to April 2012, patients electively operated and maintained under epidural catheter for postoperative analgesia were evaluated. The catheter tip was collected for semiquantitative and qualitative microbiological analysis. Of 68 cultured catheters, six tips (8.8%) had positive cultures. No patient had superficial or deep infection. The mean duration of catheter use was 43.45 h (18-118) (p=0.0894). The type of surgery (contaminated or uncontaminated), physical status of patients, and surgical time showed no relation with the colonization of catheters. Microorganisms isolated from the catheter tip were Staphylococcus aureus, Pseudomonas aeruginosa and Sphingomonas paucimobilis. Postoperative epidural catheter analgesia, under these study conditions, was found to be low risk for bacterial colonization in patients at surgical wards. Copyright © 2014 Sociedade Brasileira de Anestesiologia. Published by Elsevier Editora Ltda. All rights reserved.

  17. Effect of fibrinolysis inhibitors on survival time of irradiated rats

    International Nuclear Information System (INIS)

    Smok, W.

    1988-01-01

    The possibilities of alleviation of the gastrointestinal syndrome of acute radiation sickness by modification of haemorrhagic diathesis using EACA and traskolan were studied. A significant prolongation of the mean survival time was obtained in the irradiated rats treated with EACA. 7 tabs., 10 refs. (author)

  18. Accuracy of image-guided radiotherapy of prostate cancer based on the BeamCath urethral catheter technique

    DEFF Research Database (Denmark)

    Poulsen, Per Rugaard; Fokdal, Lars; Petersen, Jørgen B.B.

    2007-01-01

    BACKGROUND AND PURPOSE: To examine the accuracy of the BeamCath urethral catheter technique for prostate localization during radiotherapy. MATERIALS AND METHODS: Sixty-four patients were CT scanned twice with the BeamCath catheter, and once without the catheter. The catheter contains radiopaque...

  19. Successful Retrieval of a Dismembered Central Venous Catheter Stuck to the Right Pulmonary Artery Using a Stepwise Approach

    Directory of Open Access Journals (Sweden)

    Keisuke Nakabayashi

    2016-01-01

    Full Text Available Recent advances in anticancer chemotherapy have resulted in an increase in the number of patients requiring a central venous port catheter, and the incidence of catheter pinch-off syndrome has been increasing. Catheter pinch-off syndrome is a rare and unusual complication. It is difficult to retrieve dislodged catheters from the pulmonary artery, especially if the catheter is stuck to the peripheral pulmonary artery. We herein describe the successful removal of a catheter stuck in the pulmonary artery with a stepwise approach. First, a pigtail catheter was used to tug the dislodged catheter in order to free the unilateral end. Then, a gooseneck snare was used to catch and pull the catheter out of the patient. The key to success is to free the end of the catheter.

  20. Surgical complications after peritoneal dialysis catheter implantation depend on children's weight.

    Science.gov (United States)

    Radtke, Josephine; Lemke, Anja; Kemper, Markus J; Nashan, Bjoern; Koch, Martina

    2016-08-01

    Surgical complications are estimated to be as high as 30%-40% during the first 8 weeks after implantation of peritoneal dialysis (PD) catheters. 70 PD catheters which were implanted by transplant surgeons in 61 children (median age 3.3years, range 0.01-15.5years, 31 boys and 30 girls) in 2009-2014 were retrospectively reviewed. The incidence of complications and revisions during the first 6months after implantation was analyzed depending on children's weight and diagnosis. 17 out of 70 catheters needed a surgical revision within 6months after implantation (24.3%). Peritonitis was the most common complication affecting 18.6% of peritoneal dialysis catheters followed by obstruction and dislocation, which it occurred in 9 (12.9%) and 7 (10%) catheters, respectively. Leakage (n=5) only occurred in children with a weight of less than 10kg. The total proportion of complications was higher in children with less than 10kg of weight (P<0.001). PD is safe in children with acute renal failure and older children with chronic renal failure; however children with a weight of less than 10kg are more likely to develop complications. Copyright © 2016 Elsevier Inc. All rights reserved.

  1. Time-dependent analysis of incidence, risk factors and clinical significance of pneumothorax after percutaneous lung biopsy.

    Science.gov (United States)

    Lim, Woo Hyeon; Park, Chang Min; Yoon, Soon Ho; Lim, Hyun-Ju; Hwang, Eui Jin; Lee, Jong Hyuk; Goo, Jin Mo

    2018-03-01

    To evaluate the time-dependent incidence, risk factors and clinical significance of percutaneous lung biopsy (PLB)-related pneumothorax. From January 2012-November 2015, 3,251 patients underwent 3,354 cone-beam CT-guided PLBs for lung lesions. Cox, logistic and linear regression analyses were performed to identify time-dependent risk factors of PLB-related pneumothorax, risk factors of drainage catheter insertion and those of prolonged catheter placement, respectively. Pneumothorax occurred in 915/3,354 PLBs (27.3 %), with 230/915 (25.1 %) occurring during follow-ups. Risk factors for earlier occurrence of PLB-related pneumothorax include emphysema (HR=1.624), smaller target (HR=0.922), deeper location (HR=1.175) and longer puncture time (HR=1.036), while haemoptysis (HR=0.503) showed a protective effect against earlier development of pneumothorax. Seventy-five cases (8.2 %) underwent chest catheter placement. Mean duration of catheter placement was 3.2±2.0 days. Emphysema (odds ratio [OR]=2.400) and longer puncture time (OR=1.053) were assessed as significant risk factors for catheter insertion, and older age (parameter estimate=1.014) was a predictive factor for prolonged catheter placement. PLB-related pneumothorax occurred in 27.3 %, of which 25.1 % developed during follow-ups. Smaller target size, emphysema, deeply-located lesions were significant risk factors of PLB-related pneumothorax. Emphysema and older age were related to drainage catheter insertion and prolonged catheter placement, respectively. • One-fourth of percutaneous lung biopsy (PLB)-related pneumothorax occurs during follow-up. • Smaller, deeply-located target and emphysema lead to early occurrence of pneumothorax. • Emphysema is related to drainage catheter insertion for PLB-related pneumothorax. • Older age may lead to prolonged catheter placement for PLB-related pneumothorax. • Tailored management can be possible with time-dependent information of PLB-related pneumothorax.

  2. High dose urokinase for restoration of patency of occluded permanent central venous catheters in hemodialysis patients.

    Science.gov (United States)

    Shavit, L; Lifschitz, M; Plaksin, J; Grenader, T; Slotki, I

    2010-10-01

    Catheter thrombosis is common and results in inadequate dialysis treatment and, frequently, in catheter loss. Since dialysis treatment runs on a strict schedule, occluded catheters need to be restored in a timely and cost effective manner. We present a new shortened protocol of urokinase infusion that allows hemodialysis to be performed within 90 minutes. To chronic hemodialysis patients, who developed complete catheter occlusion, urokinase was infused simultaneously through both lumens of the catheter (125,000 units to each lumen) over 90 minutes. Technical success was defined as restoring blood pump speed to at least 250 ml/min. We determined the average time from catheter placement to first clot event (primary patency PP), recurrent clot event after urokinase treatment (secondary patency SP), catheter salvage rate and cause for removal. 37 catheters developed total thrombosis and urokinase was used to restore patency one or more times (total 47 treatments). Catheter salvage rate was 97 %. The average time of PP was 152 ± 56 days (7 - 784 days). Nine patients (30%) developed recurrent occlusion and the average time of SP was 64 ± 34 days (2 - 364 days). One catheter was removed because of dysfunction due to thrombosis. Other catheters were removed due to infection, fistula maturation or fell out spontaneously. Hemodialysis was performed immediately after treatment with blood speed of 250 ml/min in all patients. Our protocol is highly effective, short, and allows to restore patency of totally occluded central venous catheters with minimal disruption of the dialysis session.

  3. SU-E-T-362: Automatic Catheter Reconstruction of Flap Applicators in HDR Surface Brachytherapy

    International Nuclear Information System (INIS)

    Buzurovic, I; Devlin, P; Hansen, J; O'Farrell, D; Bhagwat, M; Friesen, S; Damato, A; Lewis, J; Cormack, R

    2014-01-01

    Purpose: Catheter reconstruction is crucial for the accurate delivery of radiation dose in HDR brachytherapy. The process becomes complicated and time-consuming for large superficial clinical targets with a complex topology. A novel method for the automatic catheter reconstruction of flap applicators is proposed in this study. Methods: We have developed a program package capable of image manipulation, using C++class libraries of The-Visualization-Toolkit(VTK) software system. The workflow for automatic catheter reconstruction is: a)an anchor point is placed in 3D or in the axial view of the first slice at the tip of the first, last and middle points for the curved surface; b)similar points are placed on the last slice of the image set; c)the surface detection algorithm automatically registers the points to the images and applies the surface reconstruction filter; d)then a structured grid surface is generated through the center of the treatment catheters placed at a distance of 5mm from the patient's skin. As a result, a mesh-style plane is generated with the reconstructed catheters placed 10mm apart. To demonstrate automatic catheter reconstruction, we used CT images of patients diagnosed with cutaneous T-cell-lymphoma and imaged with Freiburg-Flap-Applicators (Nucletron™-Elekta, Netherlands). The coordinates for each catheter were generated and compared to the control points selected during the manual reconstruction for 16catheters and 368control point Results: The variation of the catheter tip positions between the automatically and manually reconstructed catheters was 0.17mm(SD=0.23mm). The position difference between the manually selected catheter control points and the corresponding points obtained automatically was 0.17mm in the x-direction (SD=0.23mm), 0.13mm in the y-direction (SD=0.22mm), and 0.14mm in the z-direction (SD=0.24mm). Conclusion: This study shows the feasibility of the automatic catheter reconstruction of flap applicators with a high

  4. Balloon catheter dilation of benign esophageal stenosis in children

    International Nuclear Information System (INIS)

    Fan Guoping; Yu Juming; Zhong Weixing; Zhu Ming; Wu Yeming; Shi Chengren

    2001-01-01

    Objective: To evaluate the methods and effect of balloon catheter dilation of benign esophageal stenosis in children. Methods: 9 cases had an anastomotic stenosis after surgical correction of esophageal atresia; 11 cases of esophageal stenosis due to ingestion of caustics; one case had an lower esophageal stenosis after Nissen surgery and one case after gastro-esophagoplasty. Age ranged from 17 days to 7 years. Each case had a barium esophagram before balloon dilation. The balloon size varied from 3 to 10 mm in diameter. Results: 21 cases were successful after dilation of balloon catheter. There were no esophageal perforation and complications. The satisfactory results maintained from six months to thirty months. Conclusions: Balloon catheter dilation is a simple, safe and reliable method for the treatment of benign esophageal strictures in children as the first choice

  5. Managing malignant pleural effusion with an indwelling pleural catheter: factors associated with spontaneous pleurodesis.

    Science.gov (United States)

    Wong, W M; Tam, T Cc; Wong, M Ky; Lui, M Ms; Ip, M Sm; Lam, D Cl

    2016-08-01

    Malignant pleural effusion can be recurrent despite active anti-cancer treatment. Significant malignant pleural effusion leads to debilitating dyspnoea and worsening quality of life in patients with advanced cancer. An indwelling pleural catheter offers a novel means to manage recurrent malignant pleural effusion and may remove the need for repeated thoracocentesis. Spontaneous pleurodesis is another unique advantage of indwelling pleural catheter placement but the factors associated with its occurrence are not clearly established. The aims of this study were to explore the safety of an indwelling pleural catheter in the management of symptomatic recurrent malignant pleural effusion, and to identify the factors associated with spontaneous pleurodesis. This case series with internal comparisons was conducted in the Division of Respiratory Medicine, Department of Medicine, Queen Mary Hospital, Hong Kong. All patients who underwent insertion of an indwelling pleural catheter from the initiation of such service from January 2010 to December 2014 were included for data analysis. Patients were monitored until December 2014, with the last catheter inserted in July 2014. Between 2010 and 2014, a total of 23 indwelling pleural catheters were inserted in 22 consecutive patients with malignant pleural effusion, including 15 (65.2%) cases with malignant pleural effusion as a result of metastatic lung cancer. Ten (43.5%) cases achieved minimal output according to defined criteria, in five of whom the pleural catheter was removed without subsequent re-accumulation of effusion (ie spontaneous pleurodesis). Factors associated with minimal output were the absence of trapped lung (P=0.036), shorter time from first appearance of malignant pleural effusion to catheter insertion (P=0.017), and longer time from catheter insertion till patient's death or end of study (P=0.007). An indwelling pleural catheter provides a safe means to manage symptomatic malignant pleural effusion

  6. Novel Antiseptic Urinary Catheters for Prevention of Urinary Tract Infections: Correlation of In Vivo and In Vitro Test Results▿

    Science.gov (United States)

    Hachem, Ray; Reitzel, Ruth; Borne, Agatha; Jiang, Ying; Tinkey, Peggy; Uthamanthil, Rajesh; Chandra, Jyotsna; Ghannoum, Mahmoud; Raad, Issam

    2009-01-01

    Urinary catheters are widely used for hospitalized patients and are often associated with high rates of urinary tract infection. We evaluated in vitro the antiadherence activity of a novel antiseptic Gendine-coated urinary catheter against several multidrug-resistant bacteria. Gendine-coated urinary catheters were compared to silver hydrogel-coated Foley catheters and uncoated catheters. Bacterial biofilm formation was assessed by quantitative culture and scanning electron microscopy. These data were further correlated to an in vivo rabbit model. We challenged 31 rabbits daily for 4 days by inoculating the urethral meatus with 1.0 × 109 CFU streptomycin-resistant Escherichia coli per day. In vitro, Gendine-coated urinary catheters reduced the CFU of all organisms tested for biofilm adherence compared with uncoated and silver hydrogel-coated catheters (P < 0.004). Scanning electron microscopy analysis showed that a thick biofilm overlaid the control catheter and the silver hydrogel-coated catheters but not the Gendine-coated urinary catheter. Similar results were found with the rabbit model. Bacteriuria was present in 60% of rabbits with uncoated catheters and 71% of those with silver hydrogel-coated catheters (P < 0.01) but not in those with Gendine-coated urinary catheters. No rabbits with Gendine-coated urinary catheters had invasive bladder infections. Histopathologic assessment revealed no differences in toxicity or staining. Gendine-coated urinary catheters were more efficacious in preventing catheter-associated colonization and urinary tract infections than were silver hydrogel-coated Foley catheters and uncoated catheters. PMID:19805562

  7. Eomesodermin(lo) CTLA4(hi) Alloreactive CD8+ Memory T Cells Are Associated With Prolonged Renal Transplant Survival Induced by Regulatory Dendritic Cell Infusion in CTLA4 Immunoglobulin-Treated Nonhuman Primates.

    Science.gov (United States)

    Ezzelarab, Mohamed B; Lu, Lien; Guo, Hao; Zahorchak, Alan F; Shufesky, William F; Cooper, David K C; Morelli, Adrian E; Thomson, Angus W

    2016-01-01

    Memory T cells (Tmem), particularly those resistant to costimulation blockade (CB), are a major barrier to transplant tolerance. The transcription factor Eomesodermin (Eomes) is critical for Tmem development and maintenance, but its expression by alloactivated T cells has not been examined in nonhuman primates. We evaluated Eomes and coinhibitory cytotoxic T lymphocyte antigen-4 (CTLA4) expression by alloactivated rhesus monkey T cells in the presence of CTLA4 immunoglobulin, both in vitro and in renal allograft recipients treated with CTLA4Ig, with or without regulatory dendritic cell (DCreg) infusion. In normal monkeys, CD8+ T cells expressed significantly more Eomes than CD4+ T cells. By contrast, CD8+ T cells displayed minimal CTLA4. Among T cell subsets, central Tmem (Tcm) expressed the highest levels of Eomes. Notably, Eomes(lo)CTLA4(hi) cells displayed higher levels of CD25 and Foxp3 than Eomes(hi)CTLA4(lo) CD8+ T cells. After allostimulation, distinct proliferating Eomes(lo)CTLA4(hi) and Eomes(hi)CTLA4(lo) CD8+ T cell populations were identified, with a high proportion of Tcm being Eomes(lo)CTLA4(hi). CB with CTLA4Ig during allostimulation of CD8+ T cells reduced CTLA4 but not Eomes expression, significantly reducing Eomes(lo)CTLA4(hi) cells. After transplantation with CB and rapamycin, donor-reactive Eomes(lo)CTLA4(hi) CD8+ T cells were reduced. However, in monkeys also given DCreg, absolute numbers of these cells were elevated significantly. Low Eomes and high CTLA4 expression by donor-reactive CD8+ Tmem is associated with prolonged renal allograft survival induced by DCreg infusion in CTLA4Ig-treated monkeys. Prolonged allograft survival associated with DCreg infusion may be related to maintenance of donor-reactive Eomes(lo)CTLA4(hi) Tcm.

  8. Eomesoderminlo CTLA4hi Alloreactive CD8+ Memory T Cells Are Associated With Prolonged Renal Transplant Survival Induced by Regulatory Dendritic Cell Infusion in CTLA4Ig-Treated Non-Human Primates

    Science.gov (United States)

    Ezzelarab, Mohamed B.; Lu, Lien; Guo, Hao; Zahorchak, Alan F.; Shufesky, William F.; Cooper, David K.C.; Morelli, Adrian E.; Thomson, Angus W.

    2015-01-01

    Background Memory T cells (Tmem), particularly those resistant to costimulation blockade (CB), are a major barrier to transplant tolerance. The transcription factor Eomesodermin (Eomes) is critical for Tmem development and maintenance, but its expression by alloactivated T cells has not been examined in non-human primates. Methods We evaluated Eomes and co-inhibitory cytotoxic T lymphocyte antigen-4 (CTLA4) expression by alloactivated rhesus monkey T cells in the presence of CTLA4 immunoglobulin (Ig), both in vitro and in renal allograft recipients treated with CTLA4Ig, with or without regulatory dendritic cell (DCreg) infusion. Results In normal monkeys, CD8+ T cells expressed significantly more Eomes than CD4+T cells. By contrast, CD8+T cells displayed minimal CTLA4. Among T cell subsets, central Tmem (Tcm) expressed the highest levels of Eomes. Notably, EomesloCTLA4hi cells displayed higher levels of CD25 and Foxp3 than EomeshiCTLA4lo CD8+ T cells. Following allostimulation, distinct proliferating EomesloCTLA4hi and EomeshiCTLA4lo CD8+ T cell populations were identified, with a high proportion of Tcm being EomesloCTLA4hi. CB with CTLA4Ig during allostimulation of CD8+T cells reduced CTLA4 but not Eomes expression, significantly reducing EomesloCTLA4hi cells. After transplantation with CB and rapamycin, donor-reactive EomesloCTLA4hi CD8+T cells were reduced. However, in monkeys also given DCreg, absolute numbers of these cells were elevated significantly. Conclusions Low Eomes and high CTLA4 expression by donor-reactive CD8+ Tmem is associated with prolonged renal allograft survival induced by DCreg infusion in CTLA4Ig-treated monkeys. Prolonged allograft survival associated with DCreg infusion may be related to maintenance of donor-reactive EomesloCTLA4hi Tcm. PMID:26680373

  9. Ultrasound-guided Placement of a Foley Catheter Using a Hydrophilic Guide Wire

    Directory of Open Access Journals (Sweden)

    Mark Huber

    2018-03-01

    Full Text Available Acute urinary retention is a common problem in the emergency department. Patients can present in significant distress, necessitating the placement of a urinary catheter. Foley catheter placement can be difficult to accomplish depending on the etiology of the retention and the degree of the obstruction. In the case presented here, we used ultrasound guidance, a guidewire, and a Foley catheter to successfully relieve a patient’s urinary retention after multiple failed attempts.

  10. Second hematopoietic SCT for leukemia relapsing after myeloablative T cell-depleted transplants does not prolong survival.

    Science.gov (United States)

    McIver, Z A; Yin, F; Hughes, T; Battiwalla, M; Ito, S; Koklanaris, E; Haggerty, J; Hensel, N F; Barrett, A John

    2013-09-01

    Patients with leukemia relapsing after allogeneic hematopoietic SCT have a dismal prognosis. A second SCT offers a further opportunity for cure, but has a high rate of treatment failure. To determine the utility of this option, we analyzed 59 consecutive patients relapsing after a myeloablative HLA-matched sibling T cell-depleted (TCD) SCT. Twenty-five patients (13 relapsing within 6 months and 12 relapsing between 6 and 170 months after the first SCT) received a T-replete second SCT. Thirty-eight patients relapsing early had a shorter survival than the 21 patients relapsing later (median 96 vs 298 days, P=0.0002). In patients relapsing early, the second SCT did not improve OS compared with patients receiving non-SCT treatments (median survival 109 vs 80 days, P=0.41). In patients relapsing late, despite an early trend in favor of second SCT, survival was comparable for patients receiving a second SCT compared with non retransplanted patients (median survival 363.5 vs 162 days, P=0.49). Disappointingly, our results do not demonstrate an important survival benefit for a second T-replete allogeneic SCT to treat relapse following a TCD SCT.

  11. Postprocedural Aspiration Test to Predict Adequacy of Dialysis Following Tunneled Catheter Placement

    International Nuclear Information System (INIS)

    Smith, Jason C.; Sullivan, Kevin L.; Michael, Beckie

    2006-01-01

    The objective of the study was to determine if a timed aspiration technique with a 20-ml syringe can be used to predict adequacy of blood flow in tunneled dialysis catheters. Sixteen patients referred for de novo placement or manipulation of failing tunneled hemodialysis catheters had the time it takes to fill a 20-ml syringe with the plunger fully withdrawn measured to the nearest tenth of a second. These measurements were correlated with flow rates recorded in dialysis just prior to (if failed catheter) and in the following dialysis session with adequacy determined as at least 300 ml/min. Syringe-filling time (22 catheters in 16 patients) was plotted against adequacy of dialysis. The mean time to fill a 20-ml syringe was 2.2 sec, with a range of 1.0-4.7 sec. The mean time to fill syringes for catheters with adequate dialysis was 1.7 ± 0.5 sec, and for inadequate catheters, it was 2.8 ± 0.8 sec. These differences are statistically significant (p < 0.001). Using a filling time of greater than or equal to 2 sec as a threshold gives the highest sensitivity (100%) for predicting inadequate dialysis while maintaining high specificity (75%). To achieve a specificity of 100%, a 3-sec cutoff would be necessary, but would lead to a sensitivity of only 20%. A simple and objective aspiration technique can be performed at the time of tunneled dialysis catheter placement/manipulation to reasonably predict adequacy of subsequent dialysis

  12. Approach for safe visualization and localization of catheters during MR-guided intravascular procedures

    International Nuclear Information System (INIS)

    Weiss, S.; Schaeffter, T.; Brinkert, F.; Kuehne, T.; Buecker, A.

    2003-01-01

    The present paper describes a method for the visualization and localization of a catheter during real-time imaging on a clinical magnetic resonance tomograph (MRT). This method includes the use of an opposite catheter hardware equipped with an optically tunable resonant marker on its tip (OptiMa-Catheter). In the tuned state, the marker produces an intense signal spot in the MR image. The signal is modulated by optical detuning controlled by the MRT system, which results in improved visualization of the catheter tip due to flashing. During real-time imaging, additionally, the localization of the tip is precisely detected and the slice tracking automatically performed. Experiments demonstrate that the OptiMa-Catheter does not generate relevant resonance heating during imaging. Consequently, it combines the visualization and localization known from active techniques with the safety of passive techniques. (orig.) [de

  13. Current status of endovascular catheter robotics.

    Science.gov (United States)

    Lumsden, Alan B; Bismuth, Jean

    2018-06-01

    In this review, we will detail the evolution of endovascular therapy as the basis for the development of catheter-based robotics. In parallel, we will outline the evolution of robotics in the surgical space and how the convergence of technology and the entrepreneurs who push this evolution have led to the development of endovascular robots. The current state-of-the-art and future directions and potential are summarized for the reader. Information in this review has been drawn primarily from our personal clinical and preclinical experience in use of catheter robotics, coupled with some ground-breaking work reported from a few other major centers who have embraced the technology's capabilities and opportunities. Several case studies demonstrating the unique capabilities of a precisely controlled catheter are presented. Most of the preclinical work was performed in the advanced imaging and navigation laboratory. In this unique facility, the interface of advanced imaging techniques and robotic guidance is being explored. Although this procedure employs a very high-tech approach to navigation inside the endovascular space, we have conveyed the kind of opportunities that this technology affords to integrate 3D imaging and 3D control. Further, we present the opportunity of semi-autonomous motion of these devices to a target. For the interventionist, enhanced precision can be achieved in a nearly radiation-free environment.

  14. Newly Developed Biocompatible Material: Dispersible Titanium-Doped Hydroxyapatite Nanoparticles Suitable for Antibacterial Coating on Intravascular Catheters.

    Science.gov (United States)

    Furuzono, Tsutomu; Okazaki, Masatoshi; Azuma, Yoshinao; Iwasaki, Mitsunobu; Kogai, Yasumichi; Sawa, Yoshiki

    2017-01-01

    Thirteen patients with chlorhexidine-silver sulfadiazine-impregnated catheters have experienced serious anaphylactic shock in Japan. These adverse reactions highlight the lack of commercially available catheters impregnated with strong antibacterial chemical agents. A system should be developed that can control both biocompatibility and antibacterial activity. Hydroxyapatite (HAp) is biocompatible with bone and skin tissues. To provide antibacterial activity by using an external physical stimulus, titanium (Ti) ions were doped into the HAp structure. Highly dispersible, Ti-doped HAp (Ti-HAp) nanoparticles suitable as a coating material were developed. In 3 kinds of Ti-HAp [Ti/(Ca + Ti) = 0.05, 0.1, 0.2], the Ti content in the HAp was approximately 70% of that used in the Ti-HAp preparation, as determined by inductively coupled plasma atomic emission spectroscopy (ICP-AES). ICP-AES and X-ray diffraction showed Ti ions were well substituted into the HAp lattice. The nanoparticles were almost uniformly coated on a polyethylene (PE) sheet in a near-monolayer with a surface coverage ratio >95%. The antibacterial activity of the Ti-HAp nanoparticles containing 7.3% Ti ions and coating the sheet was evaluated by calculating the survival ratio of Pseudomonas aeruginosa on the coated sheet after ultraviolet (UV) irradiation. The Ti-HAp-coated sheet showed a 50% decrease in the number of P. aeruginosa compared with that on an uncoated control PE sheet after UV irradiation for 30 s. Key Messages: A system of biocompatibility and antibacterial activity with an on/off switch controlled by external UV stimulation was developed. The system is expected to be applicable in long-term implanted intravascular catheters. © 2017 S. Karger AG, Basel.

  15. Previous PICC Placement May Be Associated With Catheter-Related Infections in Hemodialysis Patients

    International Nuclear Information System (INIS)

    Butler, Philip J.; Sood, Shreya; Mojibian, Hamid; Tal, Michael G.

    2011-01-01

    Background: Catheter-related infections (CRIs) are a significant source of morbidity and mortality in hemodialysis patients. The identification of novel, modifiable risk factors for CRIs may lead to improved outcomes in this population. Peripherally inserted central catheters (PICCs) have been hypothesized to compromise vascular access due to vascular damage and venous thrombosis, whereas venous thrombosis has been linked to the development of CRIs. Here we examine the association between PICC placement and CRIs. Methods: A retrospective review was performed of all chronic hemodialysis catheter placements and exchanges performed at a large university hospital from September 2003 to September 2008. History of PICC line use was determined by examining hospital radiologic records from December 1993 to September 2008. Catheter-related complications were assessed and correlated with PICC line history. Results: One hundred eighty-five patients with 713 chronic tunneled hemodialysis catheter placements were identified. Thirty-eight of those patients (20.5%) had a history of PICC placement; these patients were more likely to have CRIs (odds ratio = 2.46, 95% confidence interval = 1.71–3.53, p < .001) compared with patients without a history of PICC placement. There was no difference between the two groups in age or number of catheters placed. Conclusion: Previous PICC placement may be associated with catheter-related infections in hemodialysis patients.

  16. Comparing cost of indwelling pleural catheter vs talc pleurodesis for malignant pleural effusion.

    Science.gov (United States)

    Penz, Erika D; Mishra, Eleanor K; Davies, Helen E; Manns, Braden J; Miller, Robert F; Rahman, Najib M

    2014-10-01

    Malignant pleural effusion is associated with short life expectancy and significant morbidity. A randomized controlled trial comparing indwelling pleural catheters (IPCs) with talc pleurodesis found that IPCs reduced in-hospital time and the need for additional procedures but were associated with excess adverse events. Using data from the clinical trial, we compared costs associated with use of IPCs and with talc pleurodesis. Resource use and adverse events were captured through case report forms over the 1-year trial follow-up. Costs for outpatient and inpatient visits, diagnostic imaging, nursing, and doctor time were obtained from the UK National Health Service reference costs and University of Kent's Unit Costs of Health and Social Care 2011 and inflated to 2013 using the UK Consumer Price Index. Procedure supply costs were obtained from the manufacturer. Difference in mean costs was compared using nonparametric bootstrapping. All costs were converted to US dollars using the Organisation for Economic Co-operation and Development Purchasing Power Parity Index. Overall mean cost (SD) for managing patients with IPCs and talc pleurodesis was $4,993 ($5,529) and $4,581 ($4,359), respectively. The incremental mean cost difference was $401, with 95% CI of -$1,387 to $2,261. The mean cost related to ongoing drainage in the IPC group was $1,011 ($732) vs $57 ($213) in the talc pleurodesis group (P = .001). This included the cost of drainage bottles, dressing changes in the first month, and catheter removal. There was no significant difference in cost of the initial intervention or adverse events between the groups. For patients with survival < 14 weeks, IPC is significantly less costly than talc pleurodesis, with mean cost difference of -$1,719 (95% CI, -$3,376 to -$85). There is no significant difference in the mean cost of managing patients with IPCs compared with talc pleurodesis. For patients with limited survival, IPC appears less costly. isrctn.org; No.: ISRCTN

  17. Efficacy of Minocycline and EDTA Lock Solution in Preventing Catheter-Related Bacteremia, Septic Phlebitis, and Endocarditis in Rabbits

    Science.gov (United States)

    Raad, Issam; Hachem, Ray; Tcholakian, Robert K.; Sherertz, Robert

    2002-01-01

    To determine the efficacy of antibiotic catheter lock solution in preventing catheter-related infections, silicone catheters were tunneled and inserted into the jugular veins of 18 rabbits. The catheters were challenged with an intraluminal injection of 105 CFU of slime-producing Staphylococcus epidermidis in 0.1 ml of water. The catheters were maintained on heparin (100 IU/ml) flush for the first 3 days. On day 3, quantitative blood samples for culture were obtained from the catheters and ear veins, which documented catheter-related bacteremia, and the rabbits were randomized to have their catheters flushed as follows: five animals were continued on heparin (100 IU/ml), five animals received vancomycin (3 mg/ml) with heparin (100 IU/ml), and eight animals received 3 mg of minocycline per ml with 30 mg of EDTA per ml (M-EDTA). All animals were killed at day 7. Blood, catheters, jugular veins, and heart valves were cultured quantitatively. Animals maintained on heparin developed catheter-related colonization, bacteremia, septic phlebitis, and endocarditis. Vancomycin-heparin partially prevented catheter colonization, bacteremia, and phlebitis (P = 0.2). M-EDTA completely prevented catheter colonization, catheter-related bacteremia, and phlebitis in all of the animals (P phlebitis, and endocarditis in rabbits. PMID:11796338

  18. Development of a New Coaxial Balloon Catheter System for Balloon-Occluded Retrograde Transvenous Obliteration (B-RTO)

    International Nuclear Information System (INIS)

    Tanoue, Shuichi; Kiyosue, Hiro; Matsumoto, Shunro; Hori, Yuzo; Okahara, Mika; Kashiwagi, Junji; Mori, Hiromu

    2006-01-01

    Purpose. To develop a new coaxial balloon catheter system and evaluate its clinical feasibility for balloon-occluded retrograde transvenous obliteration (B-RTO). Methods. A coaxial balloon catheter system was constructed with 9 Fr guiding balloon catheter and 5 Fr balloon catheter. A 5 Fr catheter has a high flexibility and can be coaxially inserted into the guiding catheter in advance. The catheter balloons are made of natural rubber and can be inflated to 2 cm (guiding) and 1 cm (5 Fr) maximum diameter. Between July 2003 and April 2005, 8 consecutive patients (6 men, 2 women; age range 33-72 years, mean age 55.5 years) underwent B-RTO using the balloon catheter system. Five percent ethanolamine oleate iopamidol (EOI) was used as sclerosing agent. The procedures, including maneuverability of the catheter, amount of injected sclerosing agent, necessity for coil embolization of collateral draining veins, and initial clinical results, were evaluated retrospectively. The occlusion rate was assessed by postcontrast CT within 2 weeks after B-RTO. Results. The balloon catheter could be advanced into the proximal potion of the gastrorenal shunt beyond the collateral draining vein in all cases. The amount of injected EOI ranged from 3 to 34 ml. Coil embolization of the collateral draining vein was required in 2 cases. Complete obliteration of gastric varices on initial follow-up CT was obtained in 7 cases. The remaining case required re-treatment that resulted in complete obstruction of the varices after the second B-RTO. No procedure-related complications were observed. Conclusion. B-RTO using the new coaxial balloon catheter is feasible. Gastric varices can be treated more simply by using this catheter system

  19. SU-E-T-574: Fessiblity of Using the Calypso System for HDR Interstitial Catheter Reconstruction

    International Nuclear Information System (INIS)

    Li, J S; Ma, C

    2014-01-01

    Purpose: It is always a challenge to reconstruct the interstitial catheter for high dose rate (HDR) brachytherapy on patient CT or MR images. This work aims to investigate the feasibility of using the Calypso system (Varian Medical, CA) for HDR catheter reconstruction utilizing its accuracy on tracking the electromagnetic transponder location. Methods: Experiment was done with a phantom that has a HDR interstitial catheter embedded inside. CT scan with a slice thickness of 1.25 mm was taken for this phantom with two Calypso beacon transponders in the catheter. The two transponders were connected with a wire. The Calypso system was used to record the beacon transponders’ location in real time when they were gently pulled out with the wire. The initial locations of the beacon transponders were used for registration with the CT image and the detected transponder locations were used for the catheter path reconstruction. The reconstructed catheter path was validated on the CT image. Results: The HDR interstitial catheter was successfully reconstructed based on the transponders’ coordinates recorded by the Calypso system in real time when the transponders were pulled in the catheter. After registration with the CT image, the shape and location of the reconstructed catheter are evaluated against the CT image and the result shows an accuracy of 2 mm anywhere in the Calypso detectable region which is within a 10 cm X 10 cm X 10 cm cubic box for the current system. Conclusion: It is feasible to use the Calypso system for HDR interstitial catheter reconstruction. The obstacle for its clinical usage is the size of the beacon transponder whose diameter is bigger than most of the interstitial catheters used in clinic. Developing smaller transponders and supporting software and hardware for this application is necessary before it can be adopted for clinical use

  20. Penile gangrene following condom catheter urinary drainage : A case report

    Directory of Open Access Journals (Sweden)

    Sandhya Gupta

    2016-04-01

    Full Text Available External urine collecting devices have been a boon to patients of urinary incontinence since their invention in late 90s. They have replaced the need for uncomfortable indwelling catheters in these patients. As safe as they may be, ghastly complications have occurred infrequently, mostly due to their inappropriate application. Such penile and urethral complications add to the morbidity of the patients significantly. They can be easily avoided by following few simple steps of catheter care, thus emphasizing the need to aware clinicians and health care workers about the correct application methods. Here we discuss a case of 60 year old male who developed penile skin necrosis and urethral fistula due to chronic use of condom catheter.