WorldWideScience

Sample records for proliferation assays performed

  1. Clonality analysis of lymphoid proliferations using the BIOMED-2 clonality assays: a single institution experience

    Science.gov (United States)

    Kokovic, Ira; Novakovic, Barbara Jezersek; Cerkovnik, Petra; Novakovic, Srdjan

    2014-01-01

    Background Clonality determination in patients with lymphoproliferative disorders can improve the final diagnosis. The aim of our study was to evaluate the applicative value of standardized BIOMED-2 gene clonality assay protocols for the analysis of clonality of lymphocytes in a group of different lymphoid proliferations. Materials and methods. With this purpose, 121 specimens from 91 patients with suspected lymphoproliferations submitted for routine diagnostics from January to December 2011 were retrospectively analyzed. According to the final diagnosis, our series comprised 32 cases of B-cell lymphomas, 38 cases of non-Hodgkin’s T-cell lymphomas and 51 cases of reactive lymphoid proliferations. Clonality testing was performed using the BIOMED-2 clonality assays. Results The determined sensitivity of the TCR assay was 91.9%, while the sensitivity of the IGH assay was 74.2%. The determined specificity of the IGH assay was 73.3% in the group of lymphomas and 87.2% in the group of reactive lesions. The determined specificity of the TCR assay was 62.5% in the group of lymphomas and 54.3% in the group of reactive lesions. Conclusions In the present study, we confirmed the utility of standardized BIOMED-2 clonality assays for the detection of clonality in a routine diagnostical setting of non-Hodgkin’s lymphomas. Reactions for the detection of the complete IGH rearrangements and reactions for the detection of the TCR rearrangements are a good choice for clonality testing of a wide range of lymphoid proliferations and specimen types while the reactions for the detection of incomplete IGH rearrangements have not shown any additional diagnostic value. PMID:24991205

  2. Understanding colonization and proliferation potential of endophytes and pathogen in planta via plating, polymerase chain reaction and ergosterol assay.

    Science.gov (United States)

    Chow, Yiing Yng; Rahman, Sadequr; Ting, Adeline Su Yien

    2017-01-01

    This study aimed to establish the colonization behavior and proliferation potential of three endophytes and one pathogen Ganoderma boninense (Gb) introduced into oil palm ramets (host model). The endophytes selected were Diaporthe phaseolorum (WAA02), Trichoderma asperellum (T2), and Penicillium citrinum (BTF08). Ramets were first inoculated with 100 mL of fungal cells (10 6  cfu mL - 1 ) via soil drenching. For the next 7 days, ramets were sampled and subjected to three different assays to detect and identify fungal colonization, and establish their proliferation potential in planta . Plate assay revealed the presence of endophytes in root, stem and leaf tissues within 7 days after inoculation. Polymerase Chain Reaction (PCR) detected and identified the isolates from the plant tissues. The ergosterol assay (via high performance liquid chromatography, HPLC) confirmed the presence of endophytes and Gb in planta . The increase in ergosterol levels throughout 49 days was however insignificant, suggesting that proliferation may be absent or may occur very slowly in planta . This study strongly suggests that the selected endophytes could colonize the host upon inoculation, but proliferation occurs at a slower rate, which may subsequently influence the biocontrol expression of endophytes against the pathogen.

  3. Understanding colonization and proliferation potential of endophytes and pathogen in planta via plating, polymerase chain reaction, and ergosterol assay

    Directory of Open Access Journals (Sweden)

    Yiing Yng Chow

    2017-01-01

    Full Text Available This study aimed to establish the colonization behavior and proliferation potential of three endophytes and one pathogen Ganoderma boninense (Gb introduced into oil palm ramets (host model. The endophytes selected were Diaporthe phaseolorum (WAA02, Trichoderma asperellum (T2, and Penicillium citrinum (BTF08. Ramets were first inoculated with 100 mL of fungal cells (106 cfu mL−1 via soil drenching. For the next 7 days, ramets were sampled and subjected to three different assays to detect and identify fungal colonization, and establish their proliferation potential in planta. Plate assay revealed the presence of endophytes in root, stem and leaf tissues within 7 days after inoculation. Polymerase Chain Reaction (PCR detected and identified the isolates from the plant tissues. The ergosterol assay (via high-performance liquid chromatography, HPLC confirmed the presence of endophytes and Gb in planta. The increase in ergosterol levels throughout 49 days was however insignificant, suggesting that proliferation may be absent or may occur very slowly in planta. This study strongly suggests that the selected endophytes could colonize the host upon inoculation, but proliferation occurs at a slower rate, which may subsequently influence the biocontrol expression of endophytes against the pathogen.

  4. ARIES nondestructive assay system operation and performance

    International Nuclear Information System (INIS)

    Cremers, Teresa L.; Hansen, Walter J.; Herrera, Gary D.; Nelson, David C.; Sampson, Thomas E.; Scheer, Nancy L.

    2000-01-01

    The ARIES (Advanced Recovery and Integrated Extraction System) Project is an integrated system at the Los Alamos Plutonium Facility for the dismantlement of nuclear weapons. The plutonium produced by the ARIES process was measured by an integrated nondestructive assay (NDA) system. The performance of the NDA systems was monitored by a measurement control program which is a part of a nuclear material control and accountability system. In this paper we will report the results of the measurements of the measurement control standards as well as an overview of the measurement of the ARIES process materials

  5. Evaluation of different toxicity assays applied to proliferating cells and to stratified epithelium in relation to permeability enhancement with glycocholate

    DEFF Research Database (Denmark)

    Eirheim, Heidi Ugelstad; Bundgaard, Christoffer; Nielsen, Hanne Mørck

    2004-01-01

    The purpose of the present study was to evaluate different toxicity assays for use on proliferating buccal TR146 cells and on stratified TR146 epithelium and to compare these results to the permeability enhancing effect of glycocholate (GC). Both the proliferating cells and the epithelium were...... across the epithelium concurrent with a decrease in the transepithelial electrical resistance (TEER) was also determined. The robustness of the epithelium was significantly higher than that of the proliferating cells (P...

  6. Dissecting the T Cell Response: Proliferation Assays vs. Cytokine Signatures by ELISPOT

    Directory of Open Access Journals (Sweden)

    Magdalena Tary-Lehmann

    2012-05-01

    Full Text Available Chronic allograft rejection is in part mediated by host T cells that recognize allogeneic antigens on transplanted tissue. One factor that determines the outcome of a T cell response is clonal size, while another is the effector quality. Studies of alloimmune predictors of transplant graft survival have most commonly focused on only one measure of the alloimmune response. Because differing qualities and frequencies of the allospecific T cell response may provide distinctly different information we analyzed the relationship between frequency of soluble antigen and allo-antigen specific memory IFN-g secreting CD4 and CD8 T cells, their ability to secrete IL-2, and their proliferative capacity, while accounting for cognate and bystander proliferation. The results show proliferative responses primarily reflect on IL-2 production by antigen-specific T cells, and that proliferating cells in such assays entail a considerable fraction of bystander cells. On the other hand, proliferation (and IL-2 production did not reflect on the frequency of IFN-γ producing memory cells, a finding particularly accentuated in the CD8 T cell compartment. These data provide rationale for considering both frequency and effector function of pre-transplant T cell reactivity when analyzing immune predictors of graft rejection.

  7. Dissecting the T Cell Response: Proliferation Assays vs. Cytokine Signatures by ELISPOT

    Science.gov (United States)

    Anthony, Donald D.; Milkovich, Kimberly A.; Zhang, Wenji; Rodriguez, Benigno; Yonkers, Nicole L.; Tary-Lehmann, Magdalena; Lehmann, Paul V.

    2012-01-01

    Chronic allograft rejection is in part mediated by host T cells that recognize allogeneic antigens on transplanted tissue. One factor that determines the outcome of a T cell response is clonal size, while another is the effector quality. Studies of alloimmune predictors of transplant graft survival have most commonly focused on only one measure of the alloimmune response. Because differing qualities and frequencies of the allospecific T cell response may provide distinctly different information we analyzed the relationship between frequency of soluble antigen and allo-antigen specific memory IFN-γ secreting CD4 and CD8 T cells, their ability to secrete IL-2, and their proliferative capacity, while accounting for cognate and bystander proliferation. The results show proliferative responses primarily reflect on IL-2 production by antigen-specific T cells, and that proliferating cells in such assays entail a considerable fraction of bystander cells. On the other hand, proliferation (and IL-2 production) did not reflect on the frequency of IFN-γ producing memory cells, a finding particularly accentuated in the CD8 T cell compartment. These data provide rationale for considering both frequency and effector function of pre-transplant T cell reactivity when analyzing immune predictors of graft rejection. PMID:24710419

  8. Proliferation assay of mouse embryonic stem (ES) cells exposed to atmospheric-pressure plasmas at room temperature

    International Nuclear Information System (INIS)

    Miura, Taichi; Hirano, Kazumi; Ogura, Chika; Ikeguchi, Masamichi; Seki, Atsushi; Nishihara, Shoko; Ando, Ayumi; Kanazawa, Tatsuya; Hamaguchi, Satoshi

    2014-01-01

    Proliferation assays of mouse embryonic stem (ES) cells have been performed with cell culture media exposed to atmospheric-pressure plasmas (APPs), which generate reactive species in the media at room temperature. It is found that serum in cell culture media functions as a scavenger of highly reactive species and tends to protect cells in the media against cellular damage. On the other hand, if serum is not present in a cell culture medium when it is exposed to APP, the medium becomes cytotoxic and cannot be detoxified by serum added afterwards. Plasma-induced cytotoxic media hinder proliferation of mouse ES cells and may even cause cell death. It is also shown by nuclear magnetic resonance spectroscopy that organic compounds in cell culture media are in general not significantly modified by plasma exposure. These results indicate that if there is no serum in media when they are exposed to APPs, highly reactive species (such as OH radicals) generated in the media by the APP exposure are immediately converted to less reactive species (such as H 2 O 2 ), which can no longer readily react with serum that is added to the medium after plasma exposure. This study has clearly shown that it is these less reactive species, rather than highly reactive species, that make the medium cytotoxic to mouse ES cells. (paper)

  9. Evaluation of estrogenic potential of flavonoids using a recombinant yeast strain and MCF7/BUS cell proliferation assay.

    Directory of Open Access Journals (Sweden)

    Flávia A Resende

    Full Text Available Phytoestrogens are of interest because of their reported beneficial effects on many human maladies including cancer, neurodegeneration, cardiovascular disease and diabetes. Furthermore, there is a search for compounds with estrogenic activity that can replace estrogen in hormone replacement therapy during menopause, without the undesirable effects of estrogen, such as the elevation of breast cancer occurrence. Thus, the principal objective of this study was to assess the estrogenic activity of flavonoids with different hydroxylation patterns: quercetin, kaempferol, luteolin, fisetin, chrysin, galangin, flavone, 3-hydroxyflavone, 5-hydroxyflavone and 7-hydroxyflavone via two different in vitro assays, the recombinant yeast assay (RYA and the MCF-7 proliferation assay (E-screen, since the most potent phytoestrogens are members of the flavonoid family. In these assays, kaempferol was the only compound that showed ERα-dependent transcriptional activation activity by RYA, showing 6.74±1.7 nM EEQ, besides acting as a full agonist for the stimulation of proliferation of MCF-7/BUS cells. The other compounds did not show detectable levels of interaction with ER under the conditions used in the RYA. However, in the E-screen assay, compounds such as galangin, luteolin and fisetin also stimulated the proliferation of MCF-7/BUS cells, acting as partial agonists. In the evaluation of antiestrogenicity, the compounds quercetin, chrysin and 3-hydroxyflavone significantly inhibited the cell proliferation induced by 17-β-estradiol in the E-screen assay, indicating that these compounds may act as estrogen receptor antagonists. Overall, it became clear in the assay results that the estrogenic activity of flavonoids was affected by small structural differences such as the number of hydroxyl groups, especially those on the B ring of the flavonoid.

  10. Limit-dilution assay and clonal expansion of all T cells capable of proliferation

    International Nuclear Information System (INIS)

    Chen, W.-F.; Wilson, A.; Scollay, R.; Shortman, K.

    1982-01-01

    A limit-dilution microculture system is presented in which almost all mature T cells, cultured at a level of about 1 cell/well, grow and expand to clones averaging 60,000 cells over an 8-9 day period. Cloning efficiency is 70-100%, so the set of expanded clones is representative of the starting T-cell population. T cells of all Lyt phenotypes form clones of progeny cells. The system involves culture in flat-bottom microtitre trays, in the presence of concanavalin A as the initiating stimulus, together with appropriately irradiated spleen filler cells and a supplementary source of soluble T cell growth factors. The resultant clones may be screened for cytolytic function, as described in the accompanying paper. The system may be used to assay the level of T cells capable of expansion or precursor function (PTL-p) by using [ 3 H]TdR uptake as a readout for the presence or absence of proliferating clones. Analysis of the frequency of positive cultures shows a good fit to the expected Poisson distribution, with no evidence of complicating suppressor or helper effects. (Auth.)

  11. Limit-dilution assay and clonal expansion of all T cells capable of proliferation

    Energy Technology Data Exchange (ETDEWEB)

    Chen, W.F.; Wilson, A.; Scollay, R.; Shortman, K. (Walter and Eliza Hall Inst. of Medical Research, Parkville (Australia))

    1982-08-13

    A limit-dilution microculture system is presented in which almost all mature T cells, cultured at a level of about 1 cell/well, grow and expand to clones averaging 60,000 cells over an 8-9 day period. Cloning efficiency is 70-100%, so the set of expanded clones is representative of the starting T-cell population. T cells of all Lyt phenotypes form clones of progeny cells. The system involves culture in flat-bottom microtitre trays, in the presence of concanavalin A as the initiating stimulus, together with appropriately irradiated spleen filler cells and a supplementary source of soluble T cell growth factors. The resultant clones may be screened for cytolytic function, as described in the accompanying paper. The system may be used to assay the level of T cells capable of expansion or precursor function (PTL-p) by using (/sup 3/H)TdR uptake as a readout for the presence or absence of proliferating clones. Analysis of the frequency of positive cultures shows a good fit to the expected Poisson distribution, with no evidence of complicating suppressor or helper effects.

  12. Performance in the WIPP nondestructive assay performance demonstration program

    Energy Technology Data Exchange (ETDEWEB)

    Marcinkiewicz, C.J. [Consolidated Technical Services, Inc., Frederick, MD (United States); Connolly, M.J.; Becker, G.K. [Lockheed Martin Idaho Technologies Company, Idaho Falls, ID (United States)

    1997-11-01

    Measurement facilities performing nondestructive assay (NDA) of wastes intended for disposal at the United States Department of Energy (DOE) Waste Isolation Pilot Plant (WIPP) are required to demonstrate their ability to meet specific Quality Assurance Objectives (QAOs). This demonstration is performed, in part, by participation in the NDA Performance Demonstration Program (PDP). The PDP is funded and managed by the Carlsbad Area Office (CAO) of DOE and is conducted by the Idaho National Engineering Laboratory. It tests the characteristics of precision, system bias and/or total uncertainty through the measurement of variable, blind combinations of simulated waste drums and certified radioactive standards. Each facility must successfully participate in the PDP using each different type of measurement system planned for use in waste characterization. The first cycle of the PDP using each different type of measurement system planned for use in waste characterization. The first cycle of the PDP was completed in July 1996 and the second is scheduled for completion by December 1996. Seven sites reported data in cycle 1 for 11 different measurement systems. This paper describes the design and operation of the PDP and provides the performance data from cycle 1. It also describes the preliminary results from cycle 2 and updates the status and future plans for the NDA PDP. 4 refs., 9 figs., 11 tabs.

  13. Performance of a Multiplex Serological Helicobacter pylori Assay on a Novel Microfluidic Assay Platform

    Directory of Open Access Journals (Sweden)

    Angela Filomena

    2017-10-01

    Full Text Available Infection with Helicobacter pylori (H. pylori occurs in 50% of the world population, and is associated with the development of ulcer and gastric cancer. Serological diagnostic tests indicate an H. pylori infection by detecting antibodies directed against H. pylori proteins. In addition to line blots, multiplex assay platforms provide smart solutions for the simultaneous analysis of antibody responses towards several H. pylori proteins. We used seven H. pylori proteins (FliD, gGT, GroEL, HpaA, CagA, VacA, and HP0231 and an H. pylori lysate for the development of a multiplex serological assay on a novel microfluidic platform. The reaction limited binding regime in the microfluidic channels allows for a short incubation time of 35 min. The developed assay showed very high sensitivity (99% and specificity (100%. Besides sensitivity and specificity, the technical validation (intra-assay CV = 3.7 ± 1.2% and inter-assay CV = 5.5 ± 1.2% demonstrates that our assay is also a robust tool for the analysis of the H. pylori-specific antibody response. The integration of the virulence factors CagA and VacA allow for the assessment of the risk for gastric cancer development. The short assay time and the performance of the platform shows the potential for implementation of such assays in a clinical setting.

  14. Quantifying rates of cell migration and cell proliferation in co-culture barrier assays reveals how skin and melanoma cells interact during melanoma spreading and invasion.

    Science.gov (United States)

    Haridas, Parvathi; Penington, Catherine J; McGovern, Jacqui A; McElwain, D L Sean; Simpson, Matthew J

    2017-06-21

    Malignant spreading involves the migration of cancer cells amongst other native cell types. For example, in vivo melanoma invasion involves individual melanoma cells migrating through native skin, which is composed of several distinct subpopulations of cells. Here, we aim to quantify how interactions between melanoma and fibroblast cells affect the collective spreading of a heterogeneous population of these cells in vitro. We perform a suite of circular barrier assays that includes: (i) monoculture assays with fibroblast cells; (ii) monoculture assays with SK-MEL-28 melanoma cells; and (iii) a series of co-culture assays initiated with three different ratios of SK-MEL-28 melanoma cells and fibroblast cells. Using immunostaining, detailed cell density histograms are constructed to illustrate how the two subpopulations of cells are spatially arranged within the spreading heterogeneous population. Calibrating the solution of a continuum partial differential equation to the experimental results from the monoculture assays allows us to estimate the cell diffusivity and the cell proliferation rate for the melanoma and the fibroblast cells, separately. Using the parameter estimates from the monoculture assays, we then make a prediction of the spatial spreading in the co-culture assays. Results show that the parameter estimates obtained from the monoculture assays lead to a reasonably accurate prediction of the spatial arrangement of the two subpopulations in the co-culture assays. Overall, the spatial pattern of spreading of the melanoma cells and the fibroblast cells is very similar in monoculture and co-culture conditions. Therefore, we find no clear evidence of any interactions other than cell-to-cell contact and crowding effects. Copyright © 2017 Elsevier Ltd. All rights reserved.

  15. Performance characteristics of the ARCHITECT anti-HCV assay.

    Science.gov (United States)

    Jonas, Gesa; Pelzer, Claudia; Beckert, Christian; Hausmann, Michael; Kapprell, Hans-Peter

    2005-10-01

    The ARCHITECT Anti-HCV assay is a fully automated high throughput chemiluminescent microparticle immunoassay (CMIA) for the detection of antibodies to structural and nonstructural proteins of the hepatitis C virus (HCV). To further enhance the performance of this test, the assay was modified to improve the specificity for blood donor specimens. The specificity of the enhanced ARCHITECT Anti-HCV assay was evaluated by screening blood donor samples randomly collected from various German blood banks, as well as hospitalized patient samples derived from Germany and the US. Additionally, antibody sensitivity was determined on commercially available anti-HCV seroconversion panels and on a commercially available worldwide anti-HCV genotype performance panel. Apparent specificity of the modified ARCHITECT Anti-HCV assay in a blood donor population consisting of 3811 specimens was 99.92%, compared to 99.76% for the current on-market assay. Additionally, antibody sensitivity was determined on commercially available anti-HCV seroconversion panels. Seroconversion sensitivity equivalent to or better than the current on-market product was observed by testing 33 seroconversion panels. This study demonstrates that the modified version of the ARCHITECT Anti-HCV assay shows improved specificity for blood donor specimens compared to the current assay on market without compromising sensitivity. With the availability of the improved ARCHITECT Anti-HCV assay and the recent launch of the ARCHITECT HIV Ag/Ab Combo assay, the ARCHITECT system now offers a full hepatitis/retrovirus menu with excellent performance on a high throughput, random access, automated analyzer, ideally suited for blood screening and diagnostic applications.

  16. Explosive performance on the non-proliferation experiment

    Energy Technology Data Exchange (ETDEWEB)

    McKown, T.O. [Los Alamos National Lab., NM (United States)

    1994-12-31

    The Explosive Effects Physics Project at the Los Alamos National Laboratory planned and conducted experiments on the Non-Proliferation Experiment (NPE) as part of its effort to define source functions for seismic waves. Since all investigations were contingent on the performance of the emplaced chemical explosive, an array of diagnostic measurements was fielded in the emplaced explosive. The CORRTEX (COntinuous Reflectometry for Radius vs Time EXperiment) system was used to investigate the explosive initiation and to determine the detonation velocities on three levels and in a number of radial directions. The CORRTEX experiments fielded in the explosive chamber will be described, including a description of the explosive emplacement from the perspective of its impact on the CORRTEX results. The data obtained are reviewed and the resulting detonation velocities are reported. A variation of detonation velocity with depth in the explosive and the apparent underdetonation and overdetonation of the explosive in different radial directions is reported.

  17. Explosive performance on the non-proliferation experiment

    Energy Technology Data Exchange (ETDEWEB)

    McKown, T.O.

    1994-03-01

    The non-proliferation experiment, originally called the chemical kiloton experiment, was planned and executed by Lawrence Livermore National Laboratory to investigate the seismic yield relationship and distinguishing seismic signals between a nuclear event and a large mass conventional explosion. The Los Alamos National Laboratory planned and conducted experiments to further their studies of the source function for signals observed seismically. Since all investigations were contingent on the performance of the emplaced chemical explosive, an array of diagnostic measurements was fielded in the emplaced explosive. The CORRTEX system was used to investigate the explosive initiation and to determine the detonation velocities in multiple levels and in numerous directions. A description of the CORRTEX experiments fielded, a review of the data obtained and some interpretations of the data are reported.

  18. Cyquant cell proliferation assay as a fluorescence-based method for in vitro screening of antimalarial activity.

    Science.gov (United States)

    Sriwilaijaroen, Nongluk; Kelly, Jane Xu; Riscoe, Michael; Wilairat, Prapon

    2004-12-01

    The appearance of drug resistant parasites and the absence of an effective vaccine have resulted in the need for new effective antimalarial drugs. Consequently, a convenient method for in vitro screening of large numbers of antimalarial drug candidates has become apparent. The CyQUANT cell proliferation assay is a highly sensitive fluorescence-based method for quantitation of cell number by measuring the strong fluorescence produced when green GR dye binds to nucleic acids. We have applied the CyQUANT assay method to evaluate the growth of Plasmodium falciparum D6 strain in culture. The GR-nucleic acid fluorescence linearly correlated with percent parasitemia at both 0.75 or 1 percent hematocrit with the same correlation coefficient of r2 = 0.99. The sensitivity of P. falciparum D6 strain to chloroquine and to 3,6-bis-omega-diethylaminoamyloxyxanthone, a novel antimalarial, determined by the CyQUANT assay were comparable to those obtained by the traditional [3H]-ethanolamine assay: IC50 value of chloroquine was 54 nM and 51 nM by the CyQUANT and [3H]-ethanolamine assay, respectively; IC50 value for 3,6-bis-omega-diethylaminoamyloxyxanthone was 254 nM and 223 nM by the CyQUANT and [3H]-ethanolamine assay, respectively. This procedure requires no radioisotope, uses simple equipment, and is an easy and convenient procedure, with no washing and harvesting steps. Moreover, all procedures can be set up continuously and thus, the CyQUANT assay is suitable in automatic high through-put drug screening of antimalarial drugs.

  19. Anticoagulants Influence the Performance of In Vitro Assays Intended for Characterization of Nanotechnology-Based Formulations

    Directory of Open Access Journals (Sweden)

    Edward Cedrone

    2017-12-01

    Full Text Available The preclinical safety assessment of novel nanotechnology-based drug products frequently relies on in vitro assays, especially during the early stages of product development, due to the limited quantities of nanomaterials available for such studies. The majority of immunological tests require donor blood. To enable such tests one has to prevent the blood from coagulating, which is usually achieved by the addition of an anticoagulant into blood collection tubes. Heparin, ethylene diamine tetraacetic acid (EDTA, and citrate are the most commonly used anticoagulants. Novel anticoagulants such as hirudin are also available but are not broadly used. Despite the notion that certain anticoagulants may influence assay performance, a systematic comparison between traditional and novel anticoagulants in the in vitro assays intended for immunological characterization of nanotechnology-based formulations is currently not available. We compared hirudin-anticoagulated blood with its traditional counterparts in the standardized immunological assay cascade, and found that the type of anticoagulant did not influence the performance of the hemolysis assay. However, hirudin was more optimal for the complement activation and leukocyte proliferation assays, while traditional anticoagulants citrate and heparin were more appropriate for the coagulation and cytokine secretion assays. The results also suggest that traditional immunological controls such as lipopolysaccharide (LPS are not reliable for understanding the role of anticoagulant in the assay performance. We observed differences in the test results between hirudin and traditional anticoagulant-prepared blood for nanomaterials at the time when no such effects were seen with traditional controls. It is, therefore, important to recognize the advantages and limitations of each anticoagulant and consider individual nanoparticles on a case-by-case basis.

  20. Predictive value of the flow cytometric PCNA - assay (proliferating cell nuclear antigen) in head and neck tumors after accelerated-hyperfractionated radiochemotherapy

    Energy Technology Data Exchange (ETDEWEB)

    Wenz, F; Lohr, F; Rudat, V; Dietz, A; Flentje, M; Wannenmacher, M

    1995-07-01

    Purpose/Objective: Proliferation of surviving tumor cells during fractionated radiotherapy may limit tumor control, especially in rapidly proliferating tumors. It has been widely accepted, that this may play a major role in head and neck tumors. Several methods for the assessment of tumor proliferation have been developed, however, most of them are either laborious, invasive or potentially toxic. Today, the gold standard is the flow cytometric BrdUrd assay. We present a flow cytometric method for detection of PCNA, which is an intranuclear proliferation associated protein, in solid human head and neck tumors and how these data correlate with outcome. Materials and Methods: Pretherapeutic biopsies of 20 inoperable patients with squamous cell carcinoma of the head and neck (T3-4N2M0) were examined. The tissue was disaggregated with pepsin/HCl, antibody staining was performed using the clone PC10. Biparametric flow cytometry was performed after a FITC conjugated secondary antibody and propidiumjodine staining was applied. The PCNA-index (i.e. percentage PCNA-positive cells), the DNA-index and the S-phase fraction (SPF, euploid tumors only) were determined. The therapy consisted of combined accelerated-hyperfractionated radiochemotherapy (66 Gy in 5 wks, concomittant boost of 1.6 Gy/d in wks 4+5, Carboplatin in wks 1+5). The median follow-up time was 14 mths (5 - 28), the clinical partners (V.R., A.D.) were 'blinded' towards the PCNA-values. Results: 13 patients suffered from disease progession and 11 died. The actuarial median survival and disease free survival (DFS) were 14.4 and 10.7 mths, respectively. The PCNA-values ranged from 3.2 to 70% (median 9%), there were 7 aneuploid and 13 euploid tumors. SFP in the euploid tumors ranged from 4 to 14.5% (median 10.5%). Neither SFP nor ploidy had a significant influence on the outcome. The patients were divided according to their PCNA-value in higher (n=10) and lower (n=10) than the median. The survival and DFS were 13

  1. A simple method to measure cell viability in proliferation and cytotoxicity assays

    Directory of Open Access Journals (Sweden)

    Ricardo Carneiro Borra

    2009-09-01

    Full Text Available Resazurin dye has been broadly used as indicator of cell viability in several types of assays for evaluation of the biocompatibility of medical and dental materials. Mitochondrial enzymes, as carriers of diaphorase activities, are probably responsible for the transference of electrons from NADPH + H+ to resazurin, which is reduced to resorufin. The level of reduction can be quantified by spectrophotometers since resazurin exhibits an absorption peak at 600 ηm and resorufin at 570 ηm wavelengths. However, the requirement of a spectrophotometer and specific filters for the quantification could be a barrier to many laboratories. Digital cameras containing red, green and blue filters, which allow the capture of red (600 to 700 ηm and green (500 to 600 ηm light wavelengths in ranges bordering on resazurin and resorufin absorption bands, could be used as an alternative method for the assessment of resazurin and resorufin concentrations. Thus, our aim was to develop a simple, cheap and precise method based on a digital CCD camera to measure the reduction of resazurin. We compared the capability of the CCD-based method to distinguish different concentrations of L929 and normal Human buccal fibroblast cell lines with that of a conventional microplate reader. The correlation was analyzed through the Pearson coefficient. The results showed a strong association between the measurements of the method developed here and those made with the microplate reader (r² = 0.996; p < 0.01 and with the cellular concentrations (r² = 0.965; p < 0.01. We concluded that the developed Colorimetric Quantification System based on CCD Images allowed rapid assessment of the cultured cell concentrations with simple equipment at a reduced cost.

  2. Probe colorimeter for quantitating enzyme-linked immunosorbent assays and other colorimetric assays performed with microplates.

    Science.gov (United States)

    Ackerman, S B; Kelley, E A

    1983-03-01

    The performance of a fiberoptic probe colorimeter (model PC800; Brinkmann Instruments, Inc., Westbury, N.Y.) for quantitating enzymatic or colorimetric assays in 96-well microtiter plates was compared with the performances of a spectrophotometer (model 240; Gilford Instrument Laboratories, Inc., Oberlin, Ohio) and a commercially available enzyme immunoassay reader (model MR590; Dynatech Laboratories, Inc., Alexandria, Va.). Alkaline phosphatase-p-nitrophenyl phosphate in 3 M NaOH was used as the chromophore source. Six types of plates were evaluated for use with the probe colorimeter; they generated reproducibility values (100% coefficient of variation) ranging from 91 to 98% when one individual made 24 independent measurements on the same dilution of chromophore on each plate. Eleven individuals each performed 24 measurements with the colorimeter on either a visually light (absorbance of 0.10 at 420 nm) or a dark (absorbance of 0.80 at 420 nm) dilution of chromophore; reproducibilities averaged 87% for the light dilution and 97% for the dark dilution. When one individual measured the same chromophore sample at least 20 times in the colorimeter, in the spectrophotometer or in the enzyme immunoassay reader, reproducibility for each instrument was greater than 99%. Measurements of a dilution series of chromophore in a fixed volume indicated that the optical responses of each instrument were linear in a range of 0.05 to 1.10 absorbance units.

  3. High-performance liquid chromatographic radioenzymatic assay for plasma catecyholamines

    International Nuclear Information System (INIS)

    Klaniecki, T.S.; Corder, C.N.; McDonald, R.H. Jr.; Feldman, J.A.

    1977-01-01

    A new assay method for plasma catecholamimes (CA) requiring only 50 μl has been developed, which uses high performance liquid chromatography (HPLC). The norepinephrine (NE), dopamine (D), and epinephrine (E) compounds found in plasma are radioactively o-methylated with S-[methyl- 3 H]-adenosyl-L-methionine ( 3 H-SAM) 3 H-SAM by the reaction of catechol-o-methyl transferase (COMT). The reaction is terminated and a standard mixture of nonradioactive o-methylated analogues of NE, D, and E is added to act as a carrier. Following separation by HPLC, the D,L-normetanephrine (NMN), 3-methoxy-4-hydroxyphenylethyl-amine or 3-methoxytyramine (3-MOT), and metanephrine (MN) radioactive peaks are collected which represent NE, D, and E, respectively. Then MNM and MN are oxidized to vanillin, and 3-MOT is acetylated. The products are subsequently separated by solvent extraction. This is necessary in order to avoid high radioactive blanks and to allow quantitation of the radioactivity by liquid scintillation spectrometry. The mean supine levels of NE, D, and E in normal subjects were respectively 182, 33, and 87 pg/ml of plasma. Similar assays on patients with pheochromocytoma revealed 797, 80, and 470 pg/ml

  4. In Vitro Endothelial Cell Proliferation Assay Reveals Distinct Levels of Proangiogenic Cytokines Characterizing Sera of Healthy Subjects and of Patients with Heart Failure

    Directory of Open Access Journals (Sweden)

    Rebecca Voltan

    2014-01-01

    Full Text Available Although myocardial angiogenesis is thought to play an important role in heart failure (HF, the involvement of circulating proinflammatory and proangiogenic cytokines in the pathogenesis and/or prognosis of HF has not been deeply investigated. By using a highly standardized proliferation assay with human endothelial cells, we first demonstrated that sera from older (mean age 52±7.6 years; n=46 healthy donors promoted endothelial cell proliferation to a significantly higher extent compared to sera obtained from younger healthy donors (mean age 29±8.6 years; n=20. The promotion of endothelial cell proliferation was accompanied by high serum levels of several proangiogenic cytokines. When we assessed endothelial cell proliferation in response to HF patients’ sera, we observed that a subset of sera (n=11 promoted cell proliferation to a significantly lesser extent compared to the majority of sera (n=18. Also, in this case, the difference between the patient groups in the ability to induce endothelial cell proliferation correlated to significant (P<0.05 differences in serum proangiogenic cytokine levels. Unexpectedly, HF patients associated to the highest endothelial proliferation index showed the worst prognosis as evaluated in terms of subsequent cardiovascular events in the follow-up, suggesting that high levels of circulating proangiogenic cytokines might be related to a worse prognosis.

  5. Immunoradiometric assay of a novel proliferation marker: tumour polypeptide specific antigen in breast cancer management in north India

    International Nuclear Information System (INIS)

    Phanna-Hazra, P.; Sharma, U.; Gupta, K.K.; Bhatnagar, V.; Idnani, R.; Gangwar, P.K.; Hazra, D.K.

    2004-01-01

    Tissue Polypeptide Specific Antigen (TPS) is a novel tumour marker defined by the monoclonal antibody M3 ,discovered by Bjorklund,which is claimed to be a proliferation marker, and belonging to the cytokeratin 8-18 family. M3 defines this antigen in particular out of a group of Tissue Polypeptide antigens (TPA) charecterised by the same Swedish group and was claimed to be a pancarcinoma antigen reportedly being elevated in several different cancers in the European literature.Pancarcinoma markers are of interest in relation to cancer detection as well as for assessing therapy and prognosis.Pancarcinoma antigens are also of interest for radiobioconjugate immunotargetting both for diagnosis as well as for therapy. There were no reports on this marker in an Indian population and therefore this study was initiated at two institutions in Meerut and Agra, both in the northern state of Uttar Pradesh. In addition to 250 healthy controls, 288 cases of breast cancer were studied .In addituion benign disorders were studied: breast fibroadenosis 16, breast fibro adenoma 5, breast abscess 4. TPS levels were determined by an immunoradiometric assay. In controls all but 4 had values less than 80 Units/1,the upper normal level quoted by Bjorklund.The relationship of the serum levels of the markers to histological grade and anatomical stage of the tumour were studied. In addition several of the cases underwent therapy with chemotherapy /radiotherapy/surgery or combinations thereof. The response to treatment during follow up was categorized as Complete emission(CR),Partial Remission (PR)Stable Disease(SD), Progressive Disease(PD)and recurrence (R) by the respective clinicians using standard criteria. In the cancer subjects there was a close correlation of TPS elevation with anatomical stage. 10 cases belonged to stage 1 with TPS levels 176.1+-103.94 Units/L ,61 to stage II(TPS levels 206.45 +-168.23).,79 to stage Ilia (TPS 251.5+-168.53),83 to stage IIIB (TPS 537.35+- 691.71),and 55

  6. Low cut-off values increase diagnostic performance of protein S assays

    NARCIS (Netherlands)

    Mulder, Rene; ten Kate, Min Ki; Kluin-Nelemans, Hanneke C.; Mulder, Andre B.

    Conflicting data have been reported on the accuracy of protein S (PS) assays for detection of hereditary PS deficiency. In this study we assessed the diagnostic performance of two total PS antigen assays, four free PS assays and three PS activity assays in a group of 28 heterozygous carriers of

  7. Evaluation of royal jelly as an alternative to fetal bovine serum in cell culture using cell proliferation assays and live cell imaging.

    Science.gov (United States)

    Musa, Marahaini; Nasir, Nurul Fatihah Mohamad; Thirumulu, Kannan Ponnuraj

    2014-01-01

    Royal jelly is a nutritious substance produced by the young nurse bees and contains significant amounts of proteins which are important for cell growth and proliferation. The aim of this study was to evaluate the effect of royal jelly as an alternative to fetal bovine serum (FBS) in cell culture using cell proliferation assays and live cell imaging. MRC-5 cells were treated with various concentrations of royal jelly extract in MTT assay. The control groups were comprised of Alpha-Minimal Essential Medium (α-MEM) alone and α-MEM with 10% FBS. Subsequently, the cell proliferation was studied for 10 days using Alamar Blue assay and live cell imaging from 48 to 72 h. The population doubling time (PDT) was determined using trypan blue assay after live cell imaging. In MTT assay, 0.156 and 0.078 mg/ml of royal jelly produced higher cell viability compared to positive control group but were not significantly different (P > 0.05). In the Alamar Blue assay, 0.156 and 0.078 mg/ml of royal jelly produced greater percentage of reduction at day 3 even though no significant difference was found (P > 0.05). Based on live cell imaging, the PDT for positive, negative, 0.156 and 0.078 mg/ml of royal jelly groups were 29.09, 62.50, 41.67 and 41.67 h respectively. No significant difference was found in the PDT between all the groups (P > 0.05). Royal jelly does not exhibit similar ability like FBS to facilitate cell growth under the present test conditions.

  8. Performance of the flow cytometric E-screen assay in screening estrogenicity of pure compounds and environmental samples

    Energy Technology Data Exchange (ETDEWEB)

    Vanparys, Caroline, E-mail: caroline.vanparys@ua.ac.be [Laboratory of Ecophysiology, Biochemistry and Toxicology, University of Antwerp, Antwerp (Belgium); Depiereux, Sophie; Nadzialek, Stephanie [Research Unit in Organismal Biology (URBO), University of Namur (FUNDP), Namur (Belgium); Robbens, Johan; Blust, Ronny [Laboratory of Ecophysiology, Biochemistry and Toxicology, University of Antwerp, Antwerp (Belgium); Kestemont, Patrick [Research Unit in Organismal Biology (URBO), University of Namur (FUNDP), Namur (Belgium); De Coen, Wim [Laboratory of Ecophysiology, Biochemistry and Toxicology, University of Antwerp, Antwerp (Belgium); European Chemicals Agency (ECHA), Helsinki (Finland)

    2010-09-15

    In vitro estrogenicity screens are believed to provide a first prioritization step in hazard characterization of endocrine disrupting chemicals. When applied to complex environmental matrices or mixture samples, they have been indicated valuable in estimating the overall estrogen-mimicking load. In this study, the performance of an adapted format of the classical E-screen or MCF-7 cell proliferation assay was profoundly evaluated to rank pure compounds as well as influents and effluents of sewage treatment plants (STPs) according to estrogenic activity. In this adapted format, flow cytometric cell cycle analysis was used to allow evaluation of the MCF-7 cell proliferative effects after only 24 h of exposure. With an average EC{sub 50} value of 2 pM and CV of 22%, this assay appears as a sensitive and reproducible system for evaluation of estrogenic activity. Moreover, estrogenic responses of 17 pure compounds corresponded well, qualitatively and quantitatively, with other in vitro and in vivo estrogenicity screens, such as the classical E-screen (R{sup 2} = 0.98), the estrogen receptor (ER) binding (R{sup 2} = 0.84) and the ER transcription activation assay (R{sup 2} = 0.87). To evaluate the applicability of this assay for complex samples, influents and effluents of 10 STPs covering different treatment processes, were compared and ranked according to estrogenic removal efficiencies. Activated sludge treatment with phosphorus and nitrogen removal appeared most effective in eliminating estrogenic activity, followed by activated sludge, lagoon and filter bed. This is well in agreement with previous findings based on chemical analysis or biological activity screens. Moreover, ER blocking experiments indicated that cell proliferative responses were mainly ER mediated, illustrating that the complexity of the end point, cell proliferation, compared to other ER screens, does not hamper the interpretation of the results. Therefore, this study, among other E-screen studies

  9. Performance of the flow cytometric E-screen assay in screening estrogenicity of pure compounds and environmental samples

    International Nuclear Information System (INIS)

    Vanparys, Caroline; Depiereux, Sophie; Nadzialek, Stephanie; Robbens, Johan; Blust, Ronny; Kestemont, Patrick; De Coen, Wim

    2010-01-01

    In vitro estrogenicity screens are believed to provide a first prioritization step in hazard characterization of endocrine disrupting chemicals. When applied to complex environmental matrices or mixture samples, they have been indicated valuable in estimating the overall estrogen-mimicking load. In this study, the performance of an adapted format of the classical E-screen or MCF-7 cell proliferation assay was profoundly evaluated to rank pure compounds as well as influents and effluents of sewage treatment plants (STPs) according to estrogenic activity. In this adapted format, flow cytometric cell cycle analysis was used to allow evaluation of the MCF-7 cell proliferative effects after only 24 h of exposure. With an average EC 50 value of 2 pM and CV of 22%, this assay appears as a sensitive and reproducible system for evaluation of estrogenic activity. Moreover, estrogenic responses of 17 pure compounds corresponded well, qualitatively and quantitatively, with other in vitro and in vivo estrogenicity screens, such as the classical E-screen (R 2 = 0.98), the estrogen receptor (ER) binding (R 2 = 0.84) and the ER transcription activation assay (R 2 = 0.87). To evaluate the applicability of this assay for complex samples, influents and effluents of 10 STPs covering different treatment processes, were compared and ranked according to estrogenic removal efficiencies. Activated sludge treatment with phosphorus and nitrogen removal appeared most effective in eliminating estrogenic activity, followed by activated sludge, lagoon and filter bed. This is well in agreement with previous findings based on chemical analysis or biological activity screens. Moreover, ER blocking experiments indicated that cell proliferative responses were mainly ER mediated, illustrating that the complexity of the end point, cell proliferation, compared to other ER screens, does not hamper the interpretation of the results. Therefore, this study, among other E-screen studies, supports the use of

  10. Monitoring T-Cell Responses in Translational Studies: Optimization of Dye-Based Proliferation Assay for Evaluation of Antigen-Specific Responses

    Directory of Open Access Journals (Sweden)

    Anja Ten Brinke

    2017-12-01

    Full Text Available Adoptive therapy with regulatory T cells or tolerance-inducing antigen (Ag-presenting cells is innovative and promising therapeutic approach to control undesired and harmful activation of the immune system, as observed in autoimmune diseases, solid organ and bone marrow transplantation. One of the critical issues to elucidate the mechanisms responsible for success or failure of these therapies and define the specificity of the therapy is the evaluation of the Ag-specific T-cell responses. Several efforts have been made to develop suitable and reproducible assays. Here, we focus on dye-based proliferation assays. We highlight with practical examples the fundamental issues to take into consideration for implementation of an effective and sensitive dye-based proliferation assay to monitor Ag-specific responses in patients. The most critical points were used to design a road map to set up and analyze the optimal assay to assess Ag-specific T-cell responses in patients undergoing different treatments. This is the first step to optimize monitoring of tolerance induction, allowing comparison of outcomes of different clinical studies. The road map can also be applied to other therapeutic interventions, not limited to tolerance induction therapies, in which Ag-specific T-cell responses are relevant such as vaccination approaches and cancer immunotherapy.

  11. Effects of donor proliferation in development aid for health on health program performance: A conceptual framework.

    Science.gov (United States)

    Pallas, Sarah Wood; Ruger, Jennifer Prah

    2017-02-01

    Development aid for health increased dramatically during the past two decades, raising concerns about inefficiency and lack of coherence among the growing number of global health donors. However, we lack a framework for how donor proliferation affects health program performance to inform theory-based evaluation of aid effectiveness policies. A review of academic and gray literature was conducted. Data were extracted from the literature sample on study design and evidence for hypothesized effects of donor proliferation on health program performance, which were iteratively grouped into categories and mapped into a new conceptual framework. In the framework, increases in the number of donors are hypothesized to increase inter-donor competition, transaction costs, donor poaching of recipient staff, recipient control over aid, and donor fragmentation, and to decrease donors' sense of accountability for overall development outcomes. There is mixed evidence on whether donor proliferation increases or decreases aid volume. These primary effects in turn affect donor innovation, information hoarding, and aid disbursement volatility, as well as recipient country health budget levels, human resource capacity, and corruption, and the determinants of health program performance. The net effect of donor proliferation on health will vary depending on the magnitude of the framework's competing effects in specific country settings. The conceptual framework provides a foundation for improving design of aid effectiveness practices to mitigate negative effects from donor proliferation while preserving its potential benefits. Copyright © 2017 Elsevier Ltd. All rights reserved.

  12. Pu-238 assay performance with the Canberra IQ3 system

    Energy Technology Data Exchange (ETDEWEB)

    Booth, L.; Gillespie, B.; Seaman, G.

    1997-11-01

    Canberra Industries has recently completed a demonstration project at the Westinghouse Savannah River Site (WSRC) to characterize 55-gallon drums containing Pu-238 contaminated waste. The goal of this project was to detect and quantify Pu-238 contaminated waste. The goal of this project was to detect and quantify Pu-238 waste to detection limits of less than 50 nCi/g using gamma assay techniques. This would permit reclassification of these drums from transuranic (TRU) waste to low-level waste (LLW). The instrument used for this assay was a Canberra IQ3 high sensitivity gamma assay system, mounted in a trailer. The results of the measurements demonstrate achievement of detection levels as low as 1 nCi/g for low density waste drums, and good correlation with known concentrations in several test drums. In addition, the data demonstrates significant advantages for using large area low-energy germanium detectors for achieving the lowest possible MDAs for gamma rays in the 80-250 keV range. 1 fig., 2 tabs.

  13. Performance of seven serological assays for diagnosing tularemia

    Science.gov (United States)

    2014-01-01

    Background Tularemia is a rare zoonotic disease caused by the Gram-negative bacterium Francisella tularensis. Serology is frequently the preferred diagnostic approach, because the pathogen is highly infectious and difficult to cultivate. The aim of this retrospective study was to determine the diagnostic accuracy of tularemia specific tests. Methods The Serazym®Anti-Francisella tularensis ELISA, Serion ELISA classic Francisella tularensis IgG/IgM, an in-house ELISA, the VIRapid® Tularemia immunochromatographic test, an in-house antigen microarray, and a Western Blot (WB) assay were evaluated. The diagnosis tularemia was established using a standard micro-agglutination assay. In total, 135 sera from a series of 110 consecutive tularemia patients were tested. Results The diagnostic sensitivity and diagnostic specificity of the tests were VIRapid (97.0% and 84.0%), Serion IgG (96.3% and 96.8%), Serion IgM (94.8% and 96.8%), Serazym (97.0% and 91.5%), in-house ELISA (95.6% and 76.6%), WB (93.3% and 83.0%), microarray (91.1% and 97.9%). Conclusions The diagnostic value of the commercial assays was proven, because the diagnostic accuracy was >90%. The diagnostic sensitivity of the in-house ELISA and the WB were acceptable, but the diagnostic accuracy was <90%. Interestingly, the antigen microarray test was very specific and had a very good positive predictive value. PMID:24885274

  14. Performance characteristics of bioassay, radioenzymatic assay, homogeneous enzyme immunoassay, and high-performance liquid chromatographic determination of serum gentamicin

    International Nuclear Information System (INIS)

    Delaney, C.J.; Opheim, K.E.; Smith, A.L.; Plorde, J.J.

    1982-01-01

    We compared the accuracy, precision, and between-method error of the microbiological assay, the radioenzymatic assay, the homogeneous enzyme immunoassay, and the high-performance liquid chromatographic assay for the quantitation of gentamicin in serum. Precision and accuracy were evaluated by reference samples prepared to contain 0.0 to 32.7 micrograms of gentamicin per ml. Correlations between the methods utilized patient sera with gentamicin concentrations ranging from 0.6 to 13.3 micrograms/ml. All methods were reliable within acceptable limits for routine clinical use; intermethod correlation coefficients exceeded 0.96. Relative to the microbiological assay, the alternative methods offer the advantage of rapid analysis. The elapsed times for acquiring data on a set of 10 specimens under routine operating conditions were 0.5 h by the enzyme immunoassay, 4 h by the radioenzymatic assay, 5 h by the high-performance liquid chromatographic assay, and 10 h by the microbiological assay

  15. SWATH Mass Spectrometry Performance Using Extended Peptide MS/MS Assay Libraries*

    Science.gov (United States)

    Wu, Jemma X.; Song, Xiaomin; Pascovici, Dana; Zaw, Thiri; Care, Natasha; Krisp, Christoph; Molloy, Mark P.

    2016-01-01

    The use of data-independent acquisition methods such as SWATH for mass spectrometry based proteomics is usually performed with peptide MS/MS assay libraries which enable identification and quantitation of peptide peak areas. Reference assay libraries can be generated locally through information dependent acquisition, or obtained from community data repositories for commonly studied organisms. However, there have been no studies performed to systematically evaluate how locally generated or repository-based assay libraries affect SWATH performance for proteomic studies. To undertake this analysis, we developed a software workflow, SwathXtend, which generates extended peptide assay libraries by integration with a local seed library and delivers statistical analysis of SWATH-quantitative comparisons. We designed test samples using peptides from a yeast extract spiked into peptides from human K562 cell lysates at three different ratios to simulate protein abundance change comparisons. SWATH-MS performance was assessed using local and external assay libraries of varying complexities and proteome compositions. These experiments demonstrated that local seed libraries integrated with external assay libraries achieve better performance than local assay libraries alone, in terms of the number of identified peptides and proteins and the specificity to detect differentially abundant proteins. Our findings show that the performance of extended assay libraries is influenced by the MS/MS feature similarity of the seed and external libraries, while statistical analysis using multiple testing corrections increases the statistical rigor needed when searching against large extended assay libraries. PMID:27161445

  16. The optimal condition of performing MTT assay for the determination of radiation sensitivity

    International Nuclear Information System (INIS)

    Hong, Semie; Kim, Il Han

    2001-01-01

    The measurement of radiation survival using a clonogenic assay, the established standard, can be difficult and time consuming. In this study, We have used the MTT assay, based on the reduction of a tetrazolium salt to a purple formazan precipitate by living cells, as a substitution for clonogenic assay and have examined the optimal condition for performing this assay in determination of radiation sensitivity. Four human cancer cell lines - PCI-1, SNU-1066, NCI-H63O and RKO cells have been used. For each cell line, a clonogenic assay and a MTT assay using Premix WST-1 solution, which is one of the tetrazolium salts and does not require washing or solubilization of the precipitate were carried out after irradiation of 0, 2, 4, 6, 8, 10 Gy, For clonogenic assay, cells in 25 cm 2 flasks were irradiated after overnight incubation and the resultant colonies containing more than 50 cells were scored after culturing the cells for 10-14 days, For MTT assay, the relationship between absorbance and cell number, optimal seeding cell number, and optimal timing of assay was determined. Then, MTT assay was performed when the irradiated cells had regained exponential growth or when the non-irradiated cells had undergone four or more doubling times. There was minimal variation in the values gained from these two methods with the standard deviation generally less than 5%, and there were no statistically significant differences between two methods according to t-test in low radiation dose (below 6 Gy). The regression analyses showed high linear correlation with the R 2 value of 0.975-0.992 between data from the two different methods. The optimal cell numbers for MTT assay were found to be dependent on plating efficiency of used cell line. Less than 300 cells/well were appropriate for cells with high plating efficiency (more than 30%). For cells with low plating efficiency (less than 30%), 500 cells/well or more were appropriate for assay. The optimal time for MTT assay was alter 6

  17. Mutagenicity of the peroxisome proliferators clofibrate, Wyeth 14,643 and di-2-ethylhexyl phthalate in the lacZ plasmid-based transgenic mouse mutation assay

    Directory of Open Access Journals (Sweden)

    Boerrigter Michaël

    2004-01-01

    Full Text Available Abstract Background Peroxisome proliferators are considered rodent carcinogens that are putative human non-carcinogens based on the presumed absence of direct genetic toxicity in rodent and human cells and the resistance of human cells to the induction of peroxisomes by peroxisome proliferators. The highly sensitive lacZ plasmid-based transgenic mouse mutation assay was employed to investigate the mutagenicity of several peroxisome proliferators based on several lines of evidence suggesting that these agents may in fact exert a genotoxic effect. Methods Male and female lacZ-plasmid based transgenic mice were treated at 4 months of age with 6 doses of 2,333 mg di-2-ethylhexyl phthalate (DHEP, 200 mg Wyeth-14,643, or 90 mg clofibrate per kg of bodyweight, respectively, over a two-week period. Control animals were treated with the respective vehicles only (35% propyl glycol for DEHP and Wyeth-14,643 treatment controls and sterile water for clofibrate treatment controls. The mutant frequency in liver, kidney and spleen DNA was determined as the proportion of retrieved mutant and wild-type lacZ plasmids expressed in Escherichia Coli C host cells employing a positive selection system for mutant plasmids. Results Exposure to DEHP or Wyeth-14,643 significantly increased the mutant frequency in liver, but not in kidney or spleen, of both female and male mice. Treatment with clofibrate did not lead to an increased mutant frequency in any of the organs studied. Conclusion The results indicate that some peroxisome proliferators display an organ-specific mutagenicity in lacZ plasmid-based transgenic mice consistent with historical observations of organ- and compound-specific carcinogenicity.

  18. Analytical and Clinical Performance Evaluation of the Abbott Architect PIVKA Assay.

    Science.gov (United States)

    Ko, Dae-Hyun; Hyun, Jungwon; Kim, Hyun Soo; Park, Min-Jeong; Kim, Jae-Seok; Park, Ji-Young; Shin, Dong Hoon; Cho, Hyoun Chan

    2018-01-01

    Protein induced by vitamin K absence (PIVKA) is measured using various assays and is used to help diagnose hepatocellular carcinoma. The present study evaluated the analytical and clinical performances of the recently released Abbott Architect PIVKA assay. Precision, linearity, and correlation tests were performed in accordance with the Clinical Laboratory Standardization Institute guidelines. Sample type suitability was assessed using serum and plasma samples from the same patients, and the reference interval was established using sera from 204 healthy individuals. The assay had coefficients of variation of 3.2-3.5% and intra-laboratory variation of 3.6-5.5%. Linearity was confirmed across the entire measurable range. The Architect PIVKA assay was comparable to the Lumipulse PIVKA assay, and the plasma and serum samples provided similar results. The lower reference limit was 13.0 mAU/mL and the upper reference limit was 37.4 mAU/mL. The ability of the Architect PIVKA assay to detect hepatocellular carcinoma was comparable to that of the alpha-fetoprotein test and the Lumipulse PIVKA assay. The Architect PIVKA assay provides excellent analytical and clinical performance, is simple for clinical laboratories to adopt, and has improved sample type suitability that could broaden the assay's utility. © 2018 by the Association of Clinical Scientists, Inc.

  19. Clinical performance of a new hepatitis B surface antigen quantitative assay with automatic dilution

    Directory of Open Access Journals (Sweden)

    Ta-Wei Liu

    2015-01-01

    Full Text Available Hepatitis B virus surface antigen (HBsAg levels reflect disease status and can predict the clinical response to antiviral treatment; however, the emergence of HBsAg mutant strains has become a challenge. The Abbott HBsAg quantification assay provides enhanced detection of HBsAg and HBsAg mutants. We aimed to evaluate the performance of the Abbott HBsAg quantification assay with automatic sample dilutions (shortened as automatic Architect assay, compared with the Abbott HBsAg quantification assay with manual sample dilutions (shortened as manual Architect assay and the Roche HBsAg quantification assay with automatic sample dilutions (shortened as Elecsys. A total of 130 sera samples obtained from 87 hepatitis B virus (HBV-infected patients were collected to assess the correlation between the automatic and manual Architect assays. Among the 87 patients, 41 provided 42 sera samples to confirm the linearity and reproducibility of the automatic Architect assay, and find out the correlation among the Elecsys and two Architect assays. The coefficients of variation (0.44–9.53% and R2 = 0.996–1, which were both determined using values obtained from the automatic Architect assay, showed good reproducibility and linearity. Results of the two Architect assays demonstrated a feasible correlation (n = 130 samples; R = 0.898, p  0.93 in all cases. In conclusion, the correlation between the automatic and manual dilution Architect assays was feasible, particularly in the HBeAg-negative and low DNA groups. With lower labor costs and less human error than the manual version, the Abbott automatic dilution Architect assay provided a good clinical performance with regard to the HBsAg levels.

  20. Performance of hepatitis B assays on the Bayer ADVIA Centaur Immunoassay System.

    Science.gov (United States)

    van Helden, Josef; Denoyel, Gérard; Karwowska, Sylwia; Reamer, Randy; Schmalz, John; Wright, Ted; Preisel-Simmons, Barbara

    2004-01-01

    Bayer HealthCare LLC, Diagnostics Division, has developed several new assays on the ADVIA Centaur immunoassay system for the detection of markers of hepatitis B virus infection in human serum and plasma. This panel includes assays for: hepatitis B surface antigen (HBsAg), a confirmatory test method for HBsAg, antibodies to hepatitis B surface antigen (anti-HBs), IgM and IgG antibodies to hepatitis B core antigen (anti-HBc Total) and IgM antibodies to hepatitis B core antigen (anti-HBc IgM). These assays employ magnetic particle separation technology with direct chemiluminescence for optimal assay performance. All of the assays are fully automated, require sample volumes ranging from 15 microl to 100 microl (with the exception of the ADVIA Centaur HBsAg Confirmatory Assay, which requires 2 x 100 microl), and have throughputs of up to 240 tests per hour. The five ADVIA Centaur HBV assays were tested in extensive performance evaluations conducted at two sites in Europe. The performance evaluations, which included samples from HBV-infected individuals, blood donors, hospitalized/clinical patients, and HBV vaccinees (for Anti-HBs evaluation), generated performance data in support of obtaining the Communautés Européennes (CE) mark for European market distribution. The HBV performance evaluations resulted in an overall diagnostic specificity > 99%, i.e. 99.94% for the ADVIA Centaur HBsAg Assay, 100% for the ADVIA Centaur Anti-HBs Assay, 100% for the ADVIA Centaur HBc IgM Assay and 99.94% for the ADVIA Centaur HBc Total Assay. All of the ADVIA Centaur assays showed a very good diagnostic sensitivity on these populations with 100% for the ADVIA Centaur HBsAg Assay, 99.0% for the ADVIA Centaur Anti-HBs Assay, 98.53% for the ADVIA Centaur HBc IgM Assay and 100% for the ADVIA Centaur HBc Total Assay. The ADVIA Centaur HBsAg Confirmatory Test confirmed 100% of the positive HBsAg samples. Testing of interfering substances and potential cross-reacting samples for all ADVIA

  1. Quantitative Validation of the Presto Blue Metabolic Assay for Online Monitoring of Cell Proliferation in a 3D Perfusion Bioreactor System.

    Science.gov (United States)

    Sonnaert, Maarten; Papantoniou, Ioannis; Luyten, Frank P; Schrooten, Jan Ir

    2015-06-01

    As the fields of tissue engineering and regenerative medicine mature toward clinical applications, the need for online monitoring both for quantitative and qualitative use becomes essential. Resazurin-based metabolic assays are frequently applied for determining cytotoxicity and have shown great potential for monitoring 3D bioreactor-facilitated cell culture. However, no quantitative correlation between the metabolic conversion rate of resazurin and cell number has been defined yet. In this work, we determined conversion rates of Presto Blue, a resazurin-based metabolic assay, for human periosteal cells during 2D and 3D static and 3D perfusion cultures. Our results showed that for the evaluated culture systems there is a quantitative correlation between the Presto Blue conversion rate and the cell number during the expansion phase with no influence of the perfusion-related parameters, that is, flow rate and shear stress. The correlation between the cell number and Presto Blue conversion subsequently enabled the definition of operating windows for optimal signal readouts. In conclusion, our data showed that the conversion of the resazurin-based Presto Blue metabolic assay can be used as a quantitative readout for online monitoring of cell proliferation in a 3D perfusion bioreactor system, although a system-specific validation is required.

  2. Quantitative Validation of the Presto Blue™ Metabolic Assay for Online Monitoring of Cell Proliferation in a 3D Perfusion Bioreactor System

    Science.gov (United States)

    Sonnaert, Maarten; Papantoniou, Ioannis; Luyten, Frank P.

    2015-01-01

    As the fields of tissue engineering and regenerative medicine mature toward clinical applications, the need for online monitoring both for quantitative and qualitative use becomes essential. Resazurin-based metabolic assays are frequently applied for determining cytotoxicity and have shown great potential for monitoring 3D bioreactor-facilitated cell culture. However, no quantitative correlation between the metabolic conversion rate of resazurin and cell number has been defined yet. In this work, we determined conversion rates of Presto Blue™, a resazurin-based metabolic assay, for human periosteal cells during 2D and 3D static and 3D perfusion cultures. Our results showed that for the evaluated culture systems there is a quantitative correlation between the Presto Blue conversion rate and the cell number during the expansion phase with no influence of the perfusion-related parameters, that is, flow rate and shear stress. The correlation between the cell number and Presto Blue conversion subsequently enabled the definition of operating windows for optimal signal readouts. In conclusion, our data showed that the conversion of the resazurin-based Presto Blue metabolic assay can be used as a quantitative readout for online monitoring of cell proliferation in a 3D perfusion bioreactor system, although a system-specific validation is required. PMID:25336207

  3. Analytical performances of the Diazyme ADA assay on the Cobas® 6000 system.

    Science.gov (United States)

    Delacour, Hervé; Sauvanet, Christophe; Ceppa, Franck; Burnat, Pascal

    2010-12-01

    To evaluate the analytical performance of the Diazyme ADA assay on the Cobas® 6000 system for pleural fluid samples analysis. Imprecision, linearity, calibration curve stability, interference, and correlation studies were completed. The Diazyme ADA assay demonstrated excellent precision (CVADA assay correlated well with the Giusti method (r(2)=0.93) but exhibited a negative bias (~ -30%). The Diazyme ADA assay on the Cobas® 6000 system represents a rapid, accurate, precise and reliable method for determination of ADA activity in pleural fluid samples. Copyright © 2010 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.

  4. Performance validation of commercially available mobile waste-assay systems: Preliminary report

    Energy Technology Data Exchange (ETDEWEB)

    Schanfein, M.; Bonner, C.; Maez, R. [Los Alamos National Lab., NM (United States)] [and others

    1997-11-01

    Prior to disposal, nuclear waste must be accurately characterized to identify and quantify the radioactive content to reduce the radioactive hazard to the public. Validation of the waste-assay systems` performance is critical for establishing the credibility of the assay results for storage and disposal purposes. Canberra Nuclear has evaluated regulations worldwide and identified standard, modular, neutron- and gamma-waste-assay systems that can be used to characterize a large portion of existing and newly generated transuranic (TRU) and low-level waste. Before making claims of guaranteeing any system`s performance for specific waste types, the standardized systems` performance be evaluated. 7 figs., 11 tabs.

  5. Performance validation of commercially available mobile waste-assay systems: Preliminary report

    International Nuclear Information System (INIS)

    Schanfein, M.; Bonner, C.; Maez, R.

    1997-01-01

    Prior to disposal, nuclear waste must be accurately characterized to identify and quantify the radioactive content to reduce the radioactive hazard to the public. Validation of the waste-assay systems' performance is critical for establishing the credibility of the assay results for storage and disposal purposes. Canberra Nuclear has evaluated regulations worldwide and identified standard, modular, neutron- and gamma-waste-assay systems that can be used to characterize a large portion of existing and newly generated transuranic (TRU) and low-level waste. Before making claims of guaranteeing any system's performance for specific waste types, the standardized systems' performance be evaluated. 7 figs., 11 tabs

  6. Evaluation of reproductive performance using milk progesterone assay

    International Nuclear Information System (INIS)

    Reimers, T.J.

    1990-01-01

    Dairy herds (472) in the northeastern United States of America were surveyed to evaluate reproductive performance. Error of oestrus detection (>> 1 ng/mL of milk progesterone) on the day of insemination was 5.1% for 4558 cows. 'Standing' and 'riding other cows' were the most accurate signs of oestrus. Of cows in or near oestrus when inseminated, 28.1% were open three weeks later, 12.9% were probably open, and 59% were probably pregnant according to milk progesterone analysis. Post-partum days to first insemination and conception rates showed positive correlation. Concentrations of progesterone in milk samples collected 21 to 24 days after service allowed prediction with 88.6% accuracy that a cow was pregnant and with 93.9% accuracy that she was not. By rectal palpation, veterinarians predicted with 92.5% accuracy that a cow was pregnant. (author). 12 refs, 4 tabs

  7. Assay for dihydroorotase using high-performance liquid chromatography with radioactivity detection

    International Nuclear Information System (INIS)

    Mehdi, S.; Wiseman, J.S.

    1989-01-01

    An assay for measuring dihydroorotase activity was devised. Radiolabeled substrate and product were separated by high-performance liquid chromatography using a reverse-phase column with ion-pairing, and the radioactivity was quantitated by flow detection

  8. Evaluation of the Clinical Performance of the HPV-Risk Assay Using the VALGENT-3 Panel.

    Science.gov (United States)

    Polman, N J; Oštrbenk, A; Xu, L; Snijders, P J F; Meijer, C J L M; Poljak, M; Heideman, D A M; Arbyn, M

    2017-12-01

    Human papillomavirus (HPV) testing is increasingly being incorporated into cervical cancer screening. The Validation of HPV Genotyping Tests (VALGENT) is a framework designed to evaluate the clinical performance of various HPV tests relative to that of the validated and accepted comparator test in a formalized and uniform manner. The aim of this study was to evaluate the clinical performance of the HPV-Risk assay with samples from the VALGENT-3 panel and to compare its performance to that of the clinically validated Hybrid Capture 2 assay (HC2). The VALGENT-3 panel comprises 1,300 consecutive samples from women participating in routine cervical cancer screening and is enriched with 300 samples from women with abnormal cytology. DNA was extracted from original ThinPrep PreservCyt medium aliquots, and HPV testing was performed using the HPV-Risk assay by investigators blind to the clinical data. HPV prevalence was analyzed, and the clinical performance of the HPV-Risk assay for the detection of cervical intraepithelial neoplasia grade 3 or worse (CIN3+) and CIN2 or worse (CIN2+) relative to the performance of HC2 was assessed. The sensitivity of the HPV-Risk assay for the detection of CIN3+ was similar to that of HC2 (relative sensitivity, 1.00; 95% confidence interval [CI], 0.95 to 1.05; P = 1.000), but the specificity of the HPV-Risk assay was significantly higher than that of HC2 (relative specificity, 1.02; 95% CI, 1.01 to 1.04; P performance of the HPV-Risk assay for the detection of CIN3+ and CIN2+ was noninferior to that of HC2, with all P values being ≤0.006. In conclusion, the HPV-Risk assay demonstrated noninferiority to the clinically validated HC2 by the use of samples from the VALGENT-3 panel for test validation and comparison. Copyright © 2017 Polman et al.

  9. Evaluation of performance of human immunodeficiency virus antigen/antibody combination assays in Taiwan.

    Science.gov (United States)

    Chang, Chun-Kai; Kao, Cheng-Feng; Lin, Pi-Han; Huang, Hui-Lin; Ho, Shu-Yuan; Wong, Kuo-Chen; Lin, Bo-Chang; Yeh, Chang-Ching; Lee, Chia-Yeh; Kao, Chuan-Liang; Lee, Chun-Nan; Chang, Sui-Yuan; Yang, Jyh-Yuan

    2017-08-01

    The fourth-generation human immunodeficiency virus (HIV) combination assay, which can simultaneously detect the presence of anti-HIV antibody and HIV antigen, has been shown to shorten the window period in HIV diagnosis compared with the third-generation HIV antibody immunoassay. This study was aimed to determine the performance of HIV combination assays in Taiwan, where the HIV-1 seroprevalence is 0.007% and HIV-2 infection has never been reported. Performance of three fourth-generation HIV Ag/Ab combination assays (Dia.Pro, Wantai, and Bio-Rad) and one third-generation HIV Ab immunoassay (AxSYM HIV 1/2 gO) was assessed. A total of 152 specimens, including 86 confirmed HIV-seropositive and 66 HIV-seronegative samples, were used in the study. The sensitivity of four assays varied from 98.8% to 100%, and specificity varied from 98.5% to 100%. Performance of the 75 equivocal samples, the HIV status of which was confirmed later, in terms of negative prediction varied from 81.8% to 87.5%. The Bio-Rad and Dia.Pro assays exhibited higher sensitivity for the detection of p24 antigen among the three fourth-generation HIV combination assays. The three fourth-generation HIV Ag/Ab combination assays exhibited better sensitivity, specificity, and negative prediction than the third-generation HIV Ab immunoassay. Copyright © 2015. Published by Elsevier B.V.

  10. A European multicenter study on the analytical performance of the VERIS HBV assay.

    Science.gov (United States)

    Braun, Patrick; Delgado, Rafael; Drago, Monica; Fanti, Diana; Fleury, Hervé; Izopet, Jacques; Lombardi, Alessandra; Mancon, Alessandro; Marcos, Maria Angeles; Sauné, Karine; O Shea, Siobhan; Pérez-Rivilla, Alfredo; Ramble, John; Trimoulet, Pascale; Vila, Jordi; Whittaker, Duncan; Artus, Alain; Rhodes, Daniel

    Hepatitis B viral load monitoring is an essential part of managing patients with chronic Hepatits B infection. Beckman Coulter has developed the VERIS HBV Assay for use on the fully automated Beckman Coulter DxN VERIS Molecular Diagnostics System. 1 OBJECTIVES: To evaluate the analytical performance of the VERIS HBV Assay at multiple European virology laboratories. Precision, analytical sensitivity, negative sample performance, linearity and performance with major HBV genotypes/subtypes for the VERIS HBV Assay was evaluated. Precision showed an SD of 0.15 log 10 IU/mL or less for each level tested. Analytical sensitivity determined by probit analysis was between 6.8-8.0 IU/mL. Clinical specificity on 90 unique patient samples was 100.0%. Performance with 754 negative samples demonstrated 100.0% not detected results, and a carryover study showed no cross contamination. Linearity using clinical samples was shown from 1.23-8.23 log 10 IU/mL and the assay detected and showed linearity with major HBV genotypes/subtypes. The VERIS HBV Assay demonstrated comparable analytical performance to other currently marketed assays for HBV DNA monitoring. Copyright © 2017 Elsevier B.V. All rights reserved.

  11. European Multicenter Study on Analytical Performance of Veris HIV-1 Assay.

    Science.gov (United States)

    Braun, Patrick; Delgado, Rafael; Drago, Monica; Fanti, Diana; Fleury, Hervé; Hofmann, Jörg; Izopet, Jacques; Kalus, Ulrich; Lombardi, Alessandra; Marcos, Maria Angeles; Mileto, Davide; Sauné, Karine; O'Shea, Siobhan; Pérez-Rivilla, Alfredo; Ramble, John; Trimoulet, Pascale; Vila, Jordi; Whittaker, Duncan; Artus, Alain; Rhodes, Daniel W

    2017-07-01

    The analytical performance of the Veris HIV-1 assay for use on the new, fully automated Beckman Coulter DxN Veris molecular diagnostics system was evaluated at 10 European virology laboratories. The precision, analytical sensitivity, performance with negative samples, linearity, and performance with HIV-1 groups/subtypes were evaluated. The precision for the 1-ml assay showed a standard deviation (SD) of 0.14 log 10 copies/ml or less and a coefficient of variation (CV) of ≤6.1% for each level tested. The 0.175-ml assay showed an SD of 0.17 log 10 copies/ml or less and a CV of ≤5.2% for each level tested. The analytical sensitivities determined by probit analysis were 19.3 copies/ml for the 1-ml assay and 126 copies/ml for the 0.175-ml assay. The performance with 1,357 negative samples demonstrated 99.2% with not detected results. Linearity using patient samples was shown from 1.54 to 6.93 log 10 copies/ml. The assay performed well, detecting and showing linearity with all HIV-1 genotypes tested. The Veris HIV-1 assay demonstrated analytical performance comparable to that of currently marketed HIV-1 assays. (DxN Veris products are Conformité Européenne [CE]-marked in vitro diagnostic products. The DxN Veris product line has not been submitted to the U.S. FDA and is not available in the U.S. market. The DxN Veris molecular diagnostics system is also known as the Veris MDx molecular diagnostics system and the Veris MDx system.). Copyright © 2017 American Society for Microbiology.

  12. A chimera embryo assay reveals a decrease in embryonic cellular proliferation induced by sperm from X-irradiated male mice

    International Nuclear Information System (INIS)

    Obasaju, M.F.; Wiley, L.M.; Oudiz, D.J.; Raabe, O.; Overstreet, J.W.

    1989-01-01

    Male mice were divided into three experimental groups and a control group. Mice in the experimental groups received one of three doses of acute X irradiation (1.73, 0.29, and 0.05 Gy) and together with the control unirradiated mice were then mated weekly to unirradiated female mice for a 9-week experimental period. Embryos were recovered from the weekly matings at the four-cell stage and examined by the chimera assay for proliferative disadvantage. Aggregation chimeras were constructed of embryos from female mice mated to irradiated males (experimental embryos) and embryos from females mated to unexposed males (control embryos) and contained either one experimental embryo and one control embryo (heterologous chimera) or two control embryos (control chimera). The control embryo in heterologous chimeras and either embryo in control chimeras were prelabeled with the vital dye fluorescein isothiocyanate (FITC), and the chimeras were cultured for 40 h and viewed under phase-contrast and epifluorescence microscopy to obtain total embryo cell number and the cellular contribution from the FITC-labeled embryo. Experimental and control embryos that were cultured singly were also examined for embryo cell number at the end of the 40-h culture period. In control chimeras, the mean ratio of the unlabeled cells:total chimera cell number (henceforth referred to as ''mean ratio'') was 0.50 with little or no weekly variation over the 9-week experimental period. During Weeks 4-7, the mean ratios of heterologous chimeras differed significantly from the mean ratio of control chimeras with the greatest differences occurring during Week 7 (0.41 for chimeras of 0.05 Gy dose group, 0.40 for chimeras of the 0.29 Gy dose group, and 0.17 for chimeras of the 1.73 Gy dose group)

  13. Evaluation of the Thermo Scientific SureTect Listeria species assay. AOAC Performance Tested Method 071304.

    Science.gov (United States)

    Cloke, Jonathan; Evans, Katharine; Crabtree, David; Hughes, Annette; Simpson, Helen; Holopainen, Jani; Wickstrand, Nina; Kauppinen, Mikko; Leon-Velarde, Carlos; Larson, Nathan; Dave, Keron

    2014-01-01

    The Thermo Scientific SureTect Listeria species Assay is a new real-time PCR assay for the detection of all species of Listeria in food and environmental samples. This validation study was conducted using the AOAC Research Institute (RI) Performance Tested Methods program to validate the SureTect Listeria species Assay in comparison to the reference method detailed in International Organization for Standardization 11290-1:1996 including amendment 1:2004 in a variety of foods plus plastic and stainless steel. The food matrixes validated were smoked salmon, processed cheese, fresh bagged spinach, cantaloupe, cooked prawns, cooked sliced turkey meat, cooked sliced ham, salami, pork frankfurters, and raw ground beef. All matrixes were tested by Thermo Fisher Scientific, Microbiology Division, Basingstoke, UK. In addition, three matrixes (pork frankfurters, fresh bagged spinach, and stainless steel surface samples) were analyzed independently as part of the AOAC-RI-controlled independent laboratory study by the University ofGuelph, Canada. Using probability of detection statistical analysis, a significant difference in favour of the SureTect assay was demonstrated between the SureTect and reference method for high level spiked samples of pork frankfurters, smoked salmon, cooked prawns, stainless steel, and low-spiked samples of salami. For all other matrixes, no significant difference was seen between the two methods during the study. Inclusivity testing was conducted with 68 different isolates of Listeria species, all of which were detected by the SureTect Listeria species Assay. None of the 33 exclusivity isolates were detected by the SureTect Listeria species Assay. Ruggedness testing was conducted to evaluate the performance of the assay with specific method deviations outside of the recommended parameters open to variation, which demonstrated that the assay gave reliable performance. Accelerated stability testing was additionally conducted, validating the assay

  14. Performance of the Xpert HIV-1 Viral Load Assay: a Systematic Review and Meta-analysis.

    Science.gov (United States)

    Nash, Madlen; Huddart, Sophie; Badar, Sayema; Baliga, Shrikala; Saravu, Kavitha; Pai, Madhukar

    2018-04-01

    Viral load (VL) is the preferred treatment-monitoring approach for HIV-positive patients. However, more rapid, near-patient, and low-complexity assays are needed to scale up VL testing. The Xpert HIV-1 VL assay (Cepheid, Sunnyvale, CA) is a new, automated molecular test, and it can leverage the GeneXpert systems that are being used widely for tuberculosis diagnosis. We systematically reviewed the evidence on the performance of this new tool in comparison to established reference standards. A total of 12 articles (13 studies) in which HIV patient VLs were compared between Xpert HIV VL assay and a reference standard VL assay were identified. Study quality was generally high, but substantial variability was observed in the number and type of agreement measures reported. Correlation coefficients between Xpert and reference assays were high, with a pooled Pearson correlation ( n = 8) of 0.94 (95% confidence interval [CI], 0.89, 0.97) and Spearman correlation ( n = 3) of 0.96 (95% CI, 0.86, 0.99). Bland-Altman metrics ( n = 11) all were within 0.35 log copies/ml of perfect agreement. Overall, Xpert HIV-1 VL performed well compared to current reference tests. The minimal training and infrastructure requirements for the Xpert HIV-1 VL assay make it attractive for use in resource-constrained settings, where point-of-care VL testing is most needed. Copyright © 2018 Nash et al.

  15. Performance evaluation of new automated hepatitis B viral markers in the clinical laboratory: two quantitative hepatitis B surface antigen assays and an HBV core-related antigen assay.

    Science.gov (United States)

    Park, Yongjung; Hong, Duck Jin; Shin, Saeam; Cho, Yonggeun; Kim, Hyon-Suk

    2012-05-01

    We evaluated quantitative hepatitis B surface antigen (qHBsAg) assays and a hepatitis B virus (HBV) core-related antigen (HBcrAg) assay. A total of 529 serum samples from patients with hepatitis B were tested. HBsAg levels were determined by using the Elecsys (Roche Diagnostics, Indianapolis, IN) and Architect (Abbott Laboratories, Abbott Park, IL) qHBsAg assays. HBcrAg was measured by using Lumipulse HBcrAg assay (Fujirebio, Tokyo, Japan). Serum aminotransferases and HBV DNA were respectively quantified by using the Hitachi 7600 analyzer (Hitachi High-Technologies, Tokyo, Japan) and the Cobas AmpliPrep/Cobas TaqMan test (Roche). Precision of the qHBsAg and HBcrAg assays was assessed, and linearity of the qHBsAg assays was verified. All assays showed good precision performance with coefficients of variation between 4.5% and 5.3% except for some levels. Both qHBsAg assays showed linearity from 0.1 to 12,000.0 IU/mL and correlated well (r = 0.9934). HBsAg levels correlated with HBV DNA (r = 0.3373) and with HBcrAg (r = 0.5164), and HBcrAg also correlated with HBV DNA (r = 0.5198; P < .0001). This observation could provide impetus for further research to elucidate the clinical usefulness of the qHBsAg and HBcrAg assays.

  16. The Davies-Gray titration for the assay of uranium in nuclear materials: a performance study

    International Nuclear Information System (INIS)

    Bickel, M.

    1997-01-01

    An interlaboratory comparison in two phases was organized to assess the precision and accuracy concerning the assay of uranium in nuclear materials by the potentiometric titration method. This contribution presents the results of this exercise in terms of method performance. Variations to be expected between different laboratories and within a single laboratory are estimated. In general, the method proved again very reliable. (orig.)

  17. How to best freeze liver samples to perform the in vivo mammalian alkaline comet assay

    Directory of Open Access Journals (Sweden)

    José Manuel Enciso Gadea

    2015-06-01

    None of the different methods used was capable of giving good results, except immersing the liver samples in liquid nitrogen, followed by Jackson’s et al. (2013 thawing protocol, suggesting that the thawing process may be as critical as the freezing process. To sum up, these results highlight the importance of deepening the possibility to perform the comet assay with frozen tissue.

  18. Performance Assessment of a Trypanosoma cruzi Chimeric Antigen in Multiplex Liquid Microarray Assays.

    Science.gov (United States)

    Santos, Fred Luciano Neves; Celedon, Paola Alejandra Fiorani; Zanchin, Nilson Ivo Tonin; Leitolis, Amanda; Crestani, Sandra; Foti, Leonardo; de Souza, Wayner Vieira; Gomes, Yara de Miranda; Krieger, Marco Aurélio

    2017-10-01

    Diagnosing chronic Chagas disease (CD) requires antibody-antigen detection methods, which are traditionally based on enzymatic assay techniques whose performance depend on the type and quality of antigen used. Previously, 4 recombinant chimeric proteins from the Instituto de Biologia Molecular do Paraná (IBMP-8.1 to 8.4) comprising immuno-dominant regions of diverse Trypanosoma cruzi antigens showed excellent diagnostic performance in enzyme-linked immunosorbent assays. Considering that next-generation platforms offer improved CD diagnostic accuracy with different T. cruzi -specific recombinant antigens, we assessed the performance of these chimeras in liquid microarrays (LMAs). The chimeric proteins were expressed in Escherichia coli and purified by chromatography. Sera from 653 chagasic and 680 healthy individuals were used to assess the performance of these chimeras in detecting specific anti- T. cruzi antibodies. Accuracies ranged from 98.1 to 99.3%, and diagnostic odds ratio values were 3,548 for IBMP-8.3, 4,826 for IBMP-8.1, 7,882 for IBMP-8.2, and 25,000 for IBMP-8.4. A separate sera bank (851 samples) was employed to assess cross-reactivity with other tropical diseases. Leishmania , a pathogen with high similarity to T. cruzi , showed cross-reactivity rates ranging from 0 to 2.17%. Inconclusive results were negligible (0 to 0.71%). Bland-Altman and Deming regression analysis based on 200 randomly selected CD-positive and negative samples demonstrated interchangeability with respect to CD diagnostic performance in both singleplex and multiplex assays. Our results suggested that these chimeras can potentially replace antigens currently used in commercially available assay kits. Moreover, the use of multiplex platforms, such as LMA assays employing 2 or more IBMP antigens, would abrogate the need for 2 different testing techniques when diagnosing CD. Copyright © 2017 American Society for Microbiology.

  19. Short Communication: Comparison of Maxim and Sedia Limiting Antigen Assay Performance for Measuring HIV Incidence.

    Science.gov (United States)

    Schlusser, Katherine E; Konikoff, Jacob; Kirkpatrick, Allison R; Morrison, Charles; Chipato, Tsungai; Chen, Pai-Lien; Munjoma, Marshall; Eshleman, Susan H; Laeyendecker, Oliver

    2017-06-01

    Accurate methods for cross-sectional incidence estimation are needed for HIV prevention research. The Limiting Antigen Avidity (LAg-Avidity) assay has been marketed by two vendors, Maxim Biomedical and Sedia BioSciences Corporation. Performance differences between the two versions of the assay are unknown. We tested a total 1,410 treatment-naive samples with both versions of the assay. The samples came from 176 seroconverters from the Zimbabwe Hormonal Contraception and HIV Study. The correlation between the two versions of the assay was 0.93 for the optical density (OD) and 0.86 for the normalized OD. As the difference was more pronounced for the normalized OD, the difference in assays can be attributed to the calibrators. The mean duration of recent infection (MDRI), the average time individuals infected 1,000 copies/ml. The MDRI was 137 days for Sedia and 157 days for Maxim, with a difference of 20 days (95% CI 11-30). The MDRIs decreased to 102 and 120 days with the inclusion of a viral load cutoff of >1,000 copies/ml. These results imply that use of the Sedia LAg-Avidity will result in estimates of incidence ∼13% lower than those using the Maxim LAg-Avidity.

  20. Evaluation of the Thermo Scientific SureTect Salmonella species assay. AOAC Performance Tested Method 051303.

    Science.gov (United States)

    Cloke, Jonathan; Clark, Dorn; Radcliff, Roy; Leon-Velarde, Carlos; Larson, Nathan; Dave, Keron; Evans, Katharine; Crabtree, David; Hughes, Annette; Simpson, Helen; Holopainen, Jani; Wickstrand, Nina; Kauppinen, Mikko

    2014-01-01

    The Thermo Scientific SureTect Salmonella species Assay is a new real-time PCR assay for the detection of Salmonellae in food and environmental samples. This validation study was conducted using the AOAC Research Institute (RI) Performance Tested Methods program to validate the SureTect Salmonella species Assay in comparison to the reference method detailed in International Organization for Standardization 6579:2002 in a variety of food matrixes, namely, raw ground beef, raw chicken breast, raw ground pork, fresh bagged lettuce, pork frankfurters, nonfat dried milk powder, cooked peeled shrimp, pasteurized liquid whole egg, ready-to-eat meal containing beef, and stainless steel surface samples. With the exception of liquid whole egg and fresh bagged lettuce, which were tested in-house, all matrixes were tested by Marshfield Food Safety, Marshfield, WI, on behalf of Thermo Fisher Scientific. In addition, three matrixes (pork frankfurters, lettuce, and stainless steel surface samples) were analyzed independently as part of the AOAC-RI-controlled laboratory study by the University of Guelph, Canada. No significant difference by probability of detection or McNemars Chi-squared statistical analysis was found between the candidate or reference methods for any of the food matrixes or environmental surface samples tested during the validation study. Inclusivity and exclusivity testing was conducted with 117 and 36 isolates, respectively, which demonstrated that the SureTect Salmonella species Assay was able to detect all the major groups of Salmonella enterica subspecies enterica (e.g., Typhimurium) and the less common subspecies of S. enterica (e.g., arizoniae) and the rarely encountered S. bongori. None of the exclusivity isolates analyzed were detected by the SureTect Salmonella species Assay. Ruggedness testing was conducted to evaluate the performance of the assay with specific method deviations outside of the recommended parameters open to variation (enrichment time

  1. Improved assay for thymine base damage in E. coli using high performance liquid chromatography

    International Nuclear Information System (INIS)

    Claycamp, H.G.

    1985-01-01

    A simple high performance liquid chromatography (HPLC) technique has been established for the simultaneous assay of thymine and thymidine radiation damage products. The HPLC procedure uses an isocratic mobile phase of 4% acetonitrile in 0.2 M ammonium dihydrogen phosphate (pH 5.0), a reversed-phase octadecylsilicate (5 micro-spherical packing) 0.45 x 25 cm column, and a variable wavelength UV detector. This procedure affords much better resolution than other published procedures that use 10 micron columns or separate assays for bases and nucleosides. For example, irradiation of 5 x 10 -3 M thymidine solutions have been performed to calibrate the system for base damage assays in E. coli. This yields up to 15 resolvable residues within 20 minutes. Sensitivity of the system (at 2210 nm) for 5,6- dihydrothymine (DHT) is about 10 -10 moles. Preliminary results show that this translates to about 0.4 DHT residues per 10 6 daltons of E. coli DNA. This is comparable to the sensitivities of monoclonal assays to thymine damage products that have recently been reported by others. Since it is feasible that the sensitivity of this system can be improved by 2-3 times, this HPLC technique should provide a simple and rapid means of detecting E. coli base damage release and base damage in nucleoside hydrolysates of DNA

  2. Point of Care Cardiac Troponin Assay Analytical Performances for their Use in Clinical Routine.

    Science.gov (United States)

    Dupuy, Anne M; Baillet, Solenne; Dumont, Richard; Giraud, Isabelle; Badiou, Stephanie; Bargnoux, Anne S; Kuster, Nils; Roubille, Francois; Cristol, Jean Paul

    2017-04-01

    We report the analytical and clinical performances of the Alere Triage Cardiac3© Panel on the Triage MeterPro© instrument, comparing concordance with hs-cTnT results from central laboratory above the respective 99th percentiles and determining the clinical sensitivity within the framework of AMI. The concordance was obtained with these two methods among unselected patients admitted to both the emergency and cardiology departments. The LoD of the assay is 0.010 µg/L. At 99th percentile (0.02 µg/L) the CV was found to be 18%, below the clinically acceptable cutoff of 20%. In the overall population, ROC AUC was not significantly different between the central laboratory assay and POC assay, with 0.952 (95% CI, 0.918 - 0.952) for hs-cTnT concentrations at presentation and 0.953 (95% CI, 0.912 - 0.953) for cTnI. Sensitivity and specificity of hs-cTnT vs. cTnI for AMI (n = 32) were 97% and 78% vs. 91% and 86%, respectively. Our results indicated 90.4% concordance between the two methods using the 99th percentile specific for each assay. The Kappa coefficient was higher than 0.75, and the strength of agreement could be considered to be good. The results of cTnI Alere assays provide similar clinical classification of patients, particularly for the AMI group as compared to the central laboratory hs-cTnT assay and could be suitable for clinical in accordance with the recommendations of Global Task Force guidelines.

  3. Performance Evaluation of a Novel Chemiluminescence Assay Detecting Treponema Pallidum Antibody as a Syphilis Screening Method.

    Science.gov (United States)

    Chen, Qixia; An, Jingna; Rao, Chenli; Wang, Tingting; Li, Dongdong; Feng, Shu; Tao, Chuanmin

    2016-01-01

    Syphilis is a major concern to global public health with increasing incidence. So its screening test should have sufficient sensitivity and specificity. We evaluated the performance of the Lumipulse G TP-N assay detection for syphilis screening and compared it with the InTec ELISA test kit for TP, which is widely used. Samples of several patient groups including 133 clinical and serologically characterized syphilitic sera, 175 samples containing potentially interfering agents, and 2290 unselected samples submitted for routine screening were detected by both the Lumipulse G TP-N assay and the InTec ELISA test kit for TP. Inconsistent samples were confirmed by RecomLine Treponema IgG, IgM immunoblot. Coefficient of variations of the Lumipulseo G TP-N assay at both levels were below 5% and of the InTec ELISA test kit for TP both over 5%. The sensitivity of the Lumipulse G TP-N assay and the InTec ELISA test kit for TP were 100% for all stages of syphilis. The two methods had consistent analytical specificity of 100% (95% CI: 97.21 - 100.00), while the clinical specificity was 100% (95% CI: 99.79 - 100.00) and 99.82% (95% CI: 99.51 - 99.94), respectively. Between them, Spearman's correlation coefficient was 0.455 and kappa value was 0.986. The overall sensitivity and specificity of the Lumipulse G TP-N assay was higher than the InTec ELISA test kit for TP (sensitivity: 100.0 versus 99.5, specificity: 100.0 versus 99.8). The automated Lumipulse G TP-N assay demonstrated excellent diagnostic sensitivity and specificity when evaluated as a screening test for syphilis. Thus, it can be an alternative to the treponemal screening test.

  4. Performance evaluation of a particle-enhanced turbidimetric cystatin C assay on the Abbott ci8200 analyzer.

    Science.gov (United States)

    Flodin, Mats; Larsson, Anders

    2009-06-01

    Glomerular filtration rate (GFR) is widely accepted as the best overall measure of kidney function. Cystatin C is a novel endogenous GFR marker that has been shown to be superior to creatinine for estimation of GFR in several studies. There is a need for cystatin C assays adapted to routine chemistry instrument to minimize turnaround times and allowing 24 h/day availability. We have evaluated a new cystatin C assay developed for Architect cSystem (Abbott Laboratories, Abbott Park, IL, USA). The cystatin C assay showed good agreement with the corresponding assay from Dade Behring (Deerfield, IL, USA). The assay has a very low total imprecision and a good linearity. The new cystatin C assay is an interesting alternative to current cystatin C assays. On an Architect cSystem the assay can be performed with the same turnaround times and availability as creatinine.

  5. Repeat testing of low-level HIV-1 RNA: assay performance and implementation in clinical trials.

    Science.gov (United States)

    White, Kirsten; Garner, Will; Wei, Lilian; Eron, Joseph J; Zhong, Lijie; Miller, Michael D; Martin, Hal; Plummer, Andrew; Tran-Muchowski, Cecilia; Lindstrom, Kim; Porter, James; Piontkowsky, David; Light, Angela; Reiske, Heinz; Quirk, Erin

    2018-05-15

    Assess the performance of HIV-1 RNA repeat testing of stored samples in cases of low-level viremia during clinical trials. Prospective and retrospective analysis of randomized clinical trial samples and reference standards. To evaluate assay variability of the Cobas AmpliPrep/Cobas TaqMan HIV-1 Test, v2.0, three separate sources of samples were utilized: the World Health Organization (WHO) HIV reference standard (assayed using 50 independent measurements at six viral loads <200 copies/ml), retrospective analysis of four to six aliquots of plasma samples from four clinical trial participants, and prospective repeat testing of 120 samples from participants in randomized trials with low-level viremia. The TaqMan assay on the WHO HIV-1 RNA standards at viral loads <200 copies/ml performed within the expected variability according to assay specifications. However, standards with low viral loads of 36 and 18 copies/ml reported values of ≥ 50 copies/ml in 66 and 18% of tests, respectively. In participants treated with antiretrovirals who had unexpected viremia of 50-200 copies/ml after achieving <50 copies/ml, retesting of multiple aliquots of stored plasma found <50 copies/ml in nearly all cases upon retesting (14/15; 93%). Repeat testing was prospectively implemented in four clinical trials for all samples with virologic rebound of 50-200 copies/ml (n = 120 samples from 92 participants) from which 42% (50/120) had a retest result of less than 50 copies/ml and 58% (70/120) retested ≥ 50 copies/ml. The TaqMan HIV-1 RNA assay shows variability around 50 copies/ml that affects clinical trial results and may impact clinical practice. In participants with a history of viral load suppression, unexpected low-level viremia may be because of assay variability rather than low drug adherence or true virologic failure. Retesting a stored aliquot of the same sample may differentiate between assay variability and virologic failure as the source of viremia

  6. Highly sensitive assay for tyrosine hydroxylase activity by high-performance liquid chromatography.

    Science.gov (United States)

    Nagatsu, T; Oka, K; Kato, T

    1979-07-21

    A highly sensitive assay for tyrosine hydroxylase (TH) activity by high-performance liquid chromatography (HPLC) with amperometric detection was devised based on the rapid isolation of enzymatically formed DOPA by a double-column procedure, the columns fitted together sequentially (the top column of Amberlite CG-50 and the bottom column of aluminium oxide). DOPA was adsorbed on the second aluminium oxide column, then eluted with 0.5 M hydrochloric acid, and assayed by HPLC with amperometric detection. D-Tyrosine was used for the control. alpha-Methyldopa was added to the incubation mixture as an internal standard after incubation. This assay was more sensitive than radioassays and 5 pmol of DOPA formed enzymatically could be measured in the presence of saturating concentrations of tyrosine and 6-methyltetrahydropterin. The TH activity in 2 mg of human putamen could be easily measured, and this method was found to be particularly suitable for the assay of TH activity in a small number of nuclei from animal and human brain.

  7. Performance of the Xpert HPV assay in women attending for cervical screening

    Directory of Open Access Journals (Sweden)

    Jack Cuzick

    2015-12-01

    Full Text Available Objectives: This study evaluated the Xpert HPV Assay in women attending screening in general practice by comparing Xpert with two established HPV tests, cytology and histology. Methods: A prospective study in women aged 20–60 years attending screening in Bristol, Edinburgh and London using residual Preservcyt cytology samples. Sample order was randomised between Roche cobas4800 and Cepheid Xpert assays with Qiagen hc2 third. Results: 3408 cases were included in the primary analysis. Positivity for Xpert was 19.6%, cobas 19.2% and hc2 19.9% with high concordance (kappa=86.8% vs cobas, 81.55 vs hc2. Xpert, cobas and hc2 showed similar sensitivity (98.7%, 97.5%, 98.7% for CIN2+. All pairwise comparisons had high concordance (Kappa ≥0.78 with any abnormal cytology. Xpert and hc2 were positive for all cases of ≥moderate dyskaryosis (N=63, cobas was negative in two. Histology was available for 172 participants. 79 reported CIN2+, 47 CIN3+. All CIN3+ was positive on Xpert and hc2 and one case negative for cobas. One case of CIN2 was negative for all assays. Conclusions: The performance of Xpert HPV Assay in a general screening population is comparable to established HPV tests. It offers simplicity of testing, flexibility with non-batching of individual samples and rapid turnaround time. Keywords: Human papillomavirus, Xpert, Cervical screening, HPV testing

  8. Combined high-performance liquid chromatography/32P-postlabeling assay of N7-methyldeoxyguanosine

    International Nuclear Information System (INIS)

    Shields, P.G.; Povey, A.C.; Wilson, V.L.; Weston, A.; Harris, C.C.

    1990-01-01

    A highly sensitive and specific assay for the detection of N7-methyl-2'-deoxyguanosine (N7methyldG) has been developed by combining high-performance liquid chromatography, 32 P-postlabeling, and nucleotide chromatography. Separation of normal nucleotides and adducts by high-performance liquid chromatography and then combining a portion of 2'-deoxyguanosine to the N7methyldG allows for quantitation using an internal standard. The directly determined molar ratio is not subject to errors in digestion, variable ATP-specific activity, or assumptions in relative adduct-labeling efficiency. The detection limit was one N7methyldG adduct in 10(7) unmodified 2'-deoxyguanosine bases. N7methyldG adducts have been detected in 5 human lung samples in which O6-methyl-2'-deoxyguanosine adducts had been previously determined. The mean ratio of N7methyldG to O6-methyl-2'-deoxyguanosine was determined to be approximately 10. The current assay complements the high-performance liquid chromatography/ 32 P-postlabeling assay for O6-methyl-2'-deoxyguanosine and increases the detection sensitivity of DNA methylated by exogenous alkylating agents

  9. Curcumin and Viscum album Extract Decrease Proliferation and Cell Viability of Soft-Tissue Sarcoma Cells: An In Vitro Analysis of Eight Cell Lines Using Real-Time Monitoring and Colorimetric Assays.

    Science.gov (United States)

    Harati, K; Behr, B; Daigeler, A; Hirsch, T; Jacobsen, F; Renner, M; Harati, A; Wallner, C; Lehnhardt, M; Becerikli, M

    2017-01-01

    The cytostatic effects of the polyphenol curcumin and Viscum album extract (VAE) were assessed in soft-tissue sarcoma (STS) cells. Eight human STS cell lines were used: fibrosarcoma (HT1080), liposarcoma (SW872, T778, MLS-402), synovial sarcoma (SW982, SYO1, 1273), and malignant fibrous histiocytoma (U2197). Primary human fibroblasts served as control cells. Cell proliferation, viability, and cell index (CI) were analyzed by BrdU assay, MTT assay, and real-time cell analysis (RTCA). As indicated by BrdU and MTT, curcumin significantly decreased the cell proliferation of five cell lines (HT1080, SW872, SYO1, 1273, and U2197) and the viability of two cell lines (SW872 and SW982). VAE led to significant decreases of proliferation in eight cell lines (HT1080, SW872, T778, MLS-402, SW982, SYO1, 1293, and U2197) and reduced viability in seven STS lines (HT1080, SW872, T778, MLS-402, SW982, SYO1, and 1273). As indicated by RTCA for 160 h, curcumin decreased the CI of all synovial sarcoma cell lines as well as T778 and HT1080. VAE diminished the CI in most of the synovial sarcoma (SW982, SYO1) and liposarcoma (SW872, T778) cell lines as well as HT1080. Primary fibroblasts were not affected adversely by the two compounds in RTCA. Curcumin and VAE can inhibit the proliferation and viability of STS cells.

  10. Stereospecific high-performance liquid chromatographic assay of sotalol in plasma.

    Science.gov (United States)

    Carr, R A; Foster, R T; Bhanji, N H

    1991-09-01

    A convenient high-performance liquid chromatographic (HPLC) assay was developed for determination of sotalol (STL) enantiomers in plasma. Following addition of the internal standard (IS; racemic atenolol), enantiomers of STL and IS were extracted using ethyl acetate. After evaporation of the organic layer, samples were derivatized with a solution of S-(+)-1-(1-naphthyl)ethyl isocyanate (NEIC). The resulting diastereomers were chromatographed with normal-phase HPLC with chloroform:hexane:methanol [65:33:2 (v/v)] as the mobile phase at a flow rate of 2 ml/min. The fluorescence detection wavelength was set at 220 nm for excitation with no emission filter. The suitability of the assay for pharmacokinetic studies was determined by measuring STL enantiomers in the plasma of a healthy subject after administration of a single 160-mg oral, racemic dose of STL.

  11. Performance of the BioPlex 2200 HIV Ag-Ab assay for identifying acute HIV infection.

    Science.gov (United States)

    Eshleman, Susan H; Piwowar-Manning, Estelle; Sivay, Mariya V; Debevec, Barbara; Veater, Stephanie; McKinstry, Laura; Bekker, Linda-Gail; Mannheimer, Sharon; Grant, Robert M; Chesney, Margaret A; Coates, Thomas J; Koblin, Beryl A; Fogel, Jessica M

    Assays that detect HIV antigen (Ag) and antibody (Ab) can be used to screen for HIV infection. To compare the performance of the BioPlex 2200 HIV Ag-Ab assay and two other Ag/Ab combination assays for detection of acute HIV infection. Samples were obtained from 24 individuals (18 from the US, 6 from South Africa); these individuals were classified as having acute infection based on the following criteria: positive qualitative RNA assay; two negative rapid tests; negative discriminatory test. The samples were tested with the BioPlex assay, the ARCHITECT HIV Ag/Ab Combo test, the Bio-Rad GS HIV Combo Ag-Ab EIA test, and a viral load assay. Twelve (50.0%) of 24 samples had RNA detected only ( > 40 to 13,476 copies/mL). Ten (43.5%) samples had reactive results with all three Ag/Ab assays, one sample was reactive with the ARCHITECT and Bio-Rad assays, and one sample was reactive with the Bio-Rad and BioPlex assays. The 11 samples that were reactive with the BioPlex assay had viral loads from 83,010 to >750,000 copies/mL; 9/11 samples were classified as Ag positive/Ab negative by the BioPlex assay. Detection of acute HIV infection was similar for the BioPlex assay and two other Ag/Ab assays. All three tests were less sensitive than a qualitative RNA assay and only detected HIV Ag when the viral load was high. The BioPlex assay detected acute infection in about half of the cases, and identified most of those infections as Ag positive/Ab negative. Copyright © 2018 Elsevier B.V. All rights reserved.

  12. Performance Demonstration Program Plan for Nondestructive Assay for the TRU Waste Characterization Program. Revision 1

    International Nuclear Information System (INIS)

    1997-01-01

    The Performance Demonstration Program (PDP) for Nondestructive Assay (NDA) consists of a series of tests conducted on a regular frequency to evaluate the capability for nondestructive assay of transuranic (TRU) waste throughout the Department of Energy (DOE) complex. Each test is termed a PDP cycle. These evaluation cycles provide an objective measure of the reliability of measurements performed with TRU waste characterization systems. Measurement facility performance will be demonstrated by the successful analysis of blind audit samples according to the criteria set by this Program Plan. Intercomparison between measurement groups of the DOE complex will be achieved by comparing the results of measurements on similar or identical blind samples reported by the different measurement facilities. Blind audit samples (hereinafter referred to as PDP samples) will be used as an independent means to assess the performance of measurement groups regarding compliance with established Quality Assurance Objectives (QAOs). As defined for this program, a PDP sample consists of a 55-gallon matrix drum emplaced with radioactive standards and fabricated matrix inserts. These PDP sample components, once manufactured, will be secured and stored at each participating measurement facility designated and authorized by Carlsbad Area Office (CAO) under secure conditions to protect them from loss, tampering, or accidental damage

  13. Association of Biotin Ingestion With Performance of Hormone and Nonhormone Assays in Healthy Adults.

    Science.gov (United States)

    Li, Danni; Radulescu, Angela; Shrestha, Rupendra T; Root, Matthew; Karger, Amy B; Killeen, Anthony A; Hodges, James S; Fan, Shu-Ling; Ferguson, Angela; Garg, Uttam; Sokoll, Lori J; Burmeister, Lynn A

    2017-09-26

    Biotinylated antibodies and analogues, with their strong binding to streptavidin, are used in many clinical laboratory tests. Excess biotin in blood due to supplemental biotin ingestion may affect biotin-streptavidin binding, leading to potential clinical misinterpretation. However, the degree of interference remains undefined in healthy adults. To assess performance of specific biotinylated immunoassays after 7 days of ingesting 10 mg/d of biotin, a dose common in over-the-counter supplements for healthy adults. Nonrandomized crossover trial involving 6 healthy adults who were treated at an academic medical center research laboratory. Administration of 10 mg/d of biotin supplementation for 7 days. Analyte concentrations were compared with baseline (day 0) measures on the seventh day of biotin treatment and 7 days after treatment had stopped (day 14). The 11 analytes included 9 hormones (ie, thyroid-stimulating hormone, total thyroxine, total triiodothyronine, free thyroxine, free triiodothyronine, parathyroid hormone, prolactin, N-terminal pro-brain natriuretic peptide, 25-hydroxyvitamin D) and 2 nonhormones (prostate-specific antigen and ferritin). A total of 37 immunoassays for the 11 analytes were evaluated on 4 diagnostic systems, including 23 assays that incorporated biotin and streptavidin components and 14 assays that did not include biotin and streptavidin components and served as negative controls. Among the 2 women and 4 men (mean age, 38 years [range, 31-45 years]) who took 10 mg/d of biotin for 7 days, biotin ingestion-associated interference was found in 9 of the 23 (39%) biotinylated assays compared with none of the 14 nonbiotinylated assays (P = .007). Results from 5 of 8 biotinylated (63%) competitive immunoassays tested falsely high and results from 4 out of 15 (27%) biotinylated sandwich immunoassays tested falsely low. In this preliminary study of 6 healthy adult participants and 11 hormone and nonhormone analytes measured by 37 immunoassays

  14. Relative performance of a TGS for the assay of drummed waste as function of collimator opening

    International Nuclear Information System (INIS)

    Kane, S.C.; Croft, S.; McClay, P.; Venkataraman, R.; Villani, M.F.

    2007-01-01

    Improving the safety, accuracy and overall cost effectiveness of the processes and methods used to characterize and handle radioactive waste is an on-going mission for the nuclear industry. An important contributor to this goal is the development of superior non-destructive assay instruments. The Tomographic Gamma Scanner (TGS) is a case in point. The TGS applies low spatial resolution experimental computed tomography (CT) linear attenuation coefficient maps with three-dimensional high-energy resolution single photon emission reconstructions. The results are presented as quantitative matrix attenuation corrected images and assay values for gamma-emitting radionuclides. Depending on a number of operational factors, this extends the diversity of waste forms that can be assayed, to a given accuracy, to items containing more heterogeneous matrix distributions and less uniform emission activity distributions. Recent advances have significantly extended the capability to a broader range of matrix density and to a wider dynamic range of surface dose rate. Automated systems sense the operational conditions, including the container type, and configure themselves accordingly. The TGS also provides a flexible data acquisition platform and can be used to perform far-field style measurements, classical segmented gamma scanner measurements, or to implement hybrid methods, such as reconstructions that use a priori knowledge to constrain the image reconstruction or the underlying energy dependence of the attenuation. A single, yet flexible, general purpose instrument of this kind adds several tiers of strategic and tactical value to facilities challenged by a diverse and difficult to assay waste streams. The TGS is still in the early phase of industrial uptake. There are only a small number of general purpose TGS systems operating worldwide, most being configured to automatically select between a few configurations appropriate for routine operations. For special investigations

  15. Utility and diagnostic performance of Mycobacterium tuberculosis complex by two immunochromatographic assays as compared with the molecular Genotype assay in Nigeria

    Directory of Open Access Journals (Sweden)

    Benjamin Thumamo Pokam

    2013-01-01

    Full Text Available Among the disadvantages of smear microscopy for detection of tuberculosis cases is its inability to differentiate between Mycobacterium tuberculosis (MTB and non-tuberculous mycobacteria (NTM. This study evaluated two, new immunochromatographic assays – Capilia TB-Neo and SD Bioline – on unheated and heated cultures at 80 °C for 30 min respectively for their ability to discriminate between MTB complex and NTM as compared with the molecular Genotype assay. Mycobacteria used in the study were obtained from smear-positive specimens collected from patients at four major hospitals in Cross River State, Nigeria. Capilia TB-Neo and SD Bioline showed sensitivities of 98.8% and 93.8% respectively and 100% specificity for both assays. Heating the isolates did not significantly impact the test performance. Both tests are recommended for use in rapid differentiation of strains isolated in Nigeria.

  16. Analytical and clinical performances of immunoradiometric assay of total and free PSA developed locally

    International Nuclear Information System (INIS)

    Boucekkine, N.; Korso, R.; Bellazoug, K.; Ferd, N.; Bouyoucef, S.E.; Boudjemai, S.; Benzaid, A.; Bouhila, Z.

    2002-01-01

    A specific assay was developed for total and free PSA (PSAt, PSAf). Both assay use a two site IRMA with polyclonal anti PSA antibodies coated on tubes. Polyclonal antibodies were obtained after rabbit's immunisation using an under skin injection of pure PSA in multiple site. For quantification, two monoclonal antibodies were selected, the first highly specific to free PSA and the second recognising both free and bound PSA. A correlation study was performed comparatively with two commercial kits from CIS Bio and Immunotech. For that purpose, 464 serums samples ranging from 0.5 ng/ml to 3399 ng/ml were used to characterise the analytical performance of the new test. The analytical detection limit of the new test was equal to 0.05 ng/ml for the total PSA and 0.02ng/ml for the free PSA. The within run and between-day coefficients of variation were to 20 ng/ml. For BPH, no significant difference was found between the three test for the ratio PSAf/PSAt using a cut off of 14% (all were>to 14%). For the 120 patients with PC, all PSAt were > to 2 ng/ml. However the mean value of PSAt was higher for the commercial kits (14.74 ng/ml against 12.48ng/ml for the new test) but all ratio of PSAf/PSAt for the 120 newly diagnosed cancer were <14%. In conclusion, our immunoradiometric assay developed locally has a good analytical performance and its outputs are well correlated to clinical findings in prostate disease. Furthermore, a cut off of 14% for the ratio PSAf/PSAt appears to be the most accurate tools to depict a prostate cancer

  17. Survey of EEC solid waste arisings and performance of non-destructive assay systems

    International Nuclear Information System (INIS)

    Bremner, W.B.; Adaway, D.W.; Yates, A.

    1992-01-01

    This report covers the work carried out during an one-year contract which surveyed the radioactive solid waste arisings in EEC Member States and also tabulated information on the performance of the non-destructive assay (NDA) system used. The work was jointly carried out with CEA partners at Cadarache and Paris. The tabulated data give information on types, packaging, associated activity, and NDA capability of the utilities or research organisations. Some short comings in NDA capabilities are identified and possible solutions are given

  18. Performance Demonstration Program Plan for Nondestructive Assay of Drummed Wastes for the TRU Waste Characterization Program

    International Nuclear Information System (INIS)

    2009-01-01

    Each testing and analytical facility performing waste characterization activities for the Waste Isolation Pilot Plant (WIPP) participates in the Performance Demonstration Program (PDP) to comply with the Transuranic Waste Acceptance Criteria for the Waste Isolation Pilot Plant (WAC) (DOE/WIPP-02-3122) and the Quality Assurance Program Document (QAPD) (CBFO-94-1012). The PDP serves as a quality control check for data generated in the characterization of waste destined for WIPP. Single blind audit samples are prepared and distributed to each of the facilities participating in the PDP. The PDP evaluates analyses of simulated headspace gases, constituents of the Resource Conservation and Recovery Act (RCRA), and transuranic (TRU) radionuclides using nondestructive assay (NDA) techniques.

  19. SRTC Spreadsheet to Determine Relative Percent Difference (RPD) for Duplicate Waste Assay Results and to Perform the RPD Acceptance Test

    International Nuclear Information System (INIS)

    Casella, V.R.

    2002-01-01

    This report documents the calculations and logic used for the Microsoft(R) Excel spreadsheet that is used at the 773-A Solid Waste Assay Facility for evaluating duplicate analyses, and validates that the spreadsheet is performing these functions correctly

  20. Evaluation of the performance of the reduced local lymph node assay for skin sensitization testing.

    Science.gov (United States)

    Ezendam, Janine; Muller, Andre; Hakkert, Betty C; van Loveren, Henk

    2013-06-01

    The local lymph node assay (LLNA) is the preferred method for classification of sensitizers within REACH. To reduce the number of mice for the identification of sensitizers the reduced LLNA was proposed, which uses only the high dose group of the LLNA. To evaluate the performance of this method for classification, LLNA data from REACH registrations were used and classification based on all dose groups was compared to classification based on the high dose group. We confirmed previous examinations of the reduced LLNA showing that this method is less sensitive compared to the LLNA. The reduced LLNA misclassified 3.3% of the sensitizers identified in the LLNA and misclassification occurred in all potency classes and that there was no clear association with irritant properties. It is therefore not possible to predict beforehand which substances might be misclassified. Another limitation of the reduced LLNA is that skin sensitizing potency cannot be assessed. For these reasons, it is not recommended to use the reduced LLNA as a stand-alone assay for skin sensitization testing within REACH. In the future, the reduced LLNA might be of added value in a weight of evidence approach to confirm negative results obtained with non-animal approaches. Copyright © 2013 Elsevier Inc. All rights reserved.

  1. Performance Values for Non-Destructive Assay (NDA) Technique Applied to Wastes: Evaluation by the ESARDA NDA Working Group

    International Nuclear Information System (INIS)

    Rackham, Jamie; Weber, Anne-Laure; Chard, Patrick

    2012-01-01

    The first evaluation of NDA performance values was undertaken by the ESARDA Working Group for Standards and Non Destructive Assay Techniques and was published in 1993. Almost ten years later in 2002 the Working Group reviewed those values and reported on improvements in performance values and new measurement techniques that had emerged since the original assessment. The 2002 evaluation of NDA performance values did not include waste measurements (although these had been incorporated into the 1993 exercise), because although the same measurement techniques are generally applied, the performance is significantly different compared to the assay of conventional Safeguarded special nuclear material. It was therefore considered more appropriate to perform a separate evaluation of performance values for waste assay. Waste assay is becoming increasingly important within the Safeguards community, particularly since the implementation of the Additional Protocol, which calls for declaration of plutonium and HEU bearing waste in addition to information on existing declared material or facilities. Improvements in the measurement performance in recent years, in particular the accuracy, mean that special nuclear materials can now be accounted for in wastes with greater certainty. This paper presents an evaluation of performance values for the NDA techniques in common usage for the assay of waste containing special nuclear material. The main topics covered by the document are: 1- Techniques for plutonium bearing solid wastes 2- Techniques for uranium bearing solid wastes 3 - Techniques for assay of fissile material in spent fuel wastes. Originally it was intended to include performance values for measurements of uranium and plutonium in liquid wastes; however, as no performance data for liquid waste measurements was obtained it was decided to exclude liquid wastes from this report. This issue of the performance values for waste assay has been evaluated and discussed by the ESARDA

  2. Performance Values for Non-Destructive Assay (NDA) Technique Applied to Wastes: Evaluation by the ESARDA NDA Working Group

    Energy Technology Data Exchange (ETDEWEB)

    Rackham, Jamie [Babcock International Group, Sellafield, Seascale, Cumbria, (United Kingdom); Weber, Anne-Laure [Institut de Radioprotection et de Surete Nucleaire Fontenay-Aux-Roses (France); Chard, Patrick [Canberra, Forss Business and Technology park, Thurso, Caithness (United Kingdom)

    2012-12-15

    The first evaluation of NDA performance values was undertaken by the ESARDA Working Group for Standards and Non Destructive Assay Techniques and was published in 1993. Almost ten years later in 2002 the Working Group reviewed those values and reported on improvements in performance values and new measurement techniques that had emerged since the original assessment. The 2002 evaluation of NDA performance values did not include waste measurements (although these had been incorporated into the 1993 exercise), because although the same measurement techniques are generally applied, the performance is significantly different compared to the assay of conventional Safeguarded special nuclear material. It was therefore considered more appropriate to perform a separate evaluation of performance values for waste assay. Waste assay is becoming increasingly important within the Safeguards community, particularly since the implementation of the Additional Protocol, which calls for declaration of plutonium and HEU bearing waste in addition to information on existing declared material or facilities. Improvements in the measurement performance in recent years, in particular the accuracy, mean that special nuclear materials can now be accounted for in wastes with greater certainty. This paper presents an evaluation of performance values for the NDA techniques in common usage for the assay of waste containing special nuclear material. The main topics covered by the document are: 1- Techniques for plutonium bearing solid wastes 2- Techniques for uranium bearing solid wastes 3 - Techniques for assay of fissile material in spent fuel wastes. Originally it was intended to include performance values for measurements of uranium and plutonium in liquid wastes; however, as no performance data for liquid waste measurements was obtained it was decided to exclude liquid wastes from this report. This issue of the performance values for waste assay has been evaluated and discussed by the ESARDA

  3. Performance Demonstration Program Plan for Nondestructive Assay of Drummed Wastes for the TRU Waste Characterization Program

    International Nuclear Information System (INIS)

    DOE Carlsbad Field Office

    2001-01-01

    The Performance Demonstration Program (PDP) for nondestructive assay (NDA) consists of a series of tests to evaluate the capability for NDA of transuranic (TRU) waste throughout the Department of Energy (DOE) complex. Each test is termed a PDP cycle. These evaluation cycles provide an objective measure of the reliability of measurements obtained from NDA systems used to characterize the radiological constituents of TRU waste. The primary documents governing the conduct of the PDP are the Waste Acceptance Criteria for the Waste Isolation Pilot Plant (WAC; DOE 1999a) and the Quality Assurance Program Document (QAPD; DOE 1999b). The WAC requires participation in the PDP; the PDP must comply with the QAPD and the WAC. The WAC contains technical and quality requirements for acceptable NDA. This plan implements the general requirements of the QAPD and applicable requirements of the WAC for the NDA PDP. Measurement facilities demonstrate acceptable performance by the successful testing of simulated waste containers according to the criteria set by this PDP Plan. Comparison among DOE measurement groups and commercial assay services is achieved by comparing the results of measurements on similar simulated waste containers reported by the different measurement facilities. These tests are used as an independent means to assess the performance of measurement groups regarding compliance with established quality assurance objectives (QAO's). Measurement facilities must analyze the simulated waste containers using the same procedures used for normal waste characterization activities. For the drummed waste PDP, a simulated waste container consists of a 55-gallon matrix drum emplaced with radioactive standards and fabricated matrix inserts. These PDP sample components are distributed to the participating measurement facilities that have been designated and authorized by the Carlsbad Field Office (CBFO). The NDA Drum PDP materials are stored at these sites under secure conditions to

  4. An interferon-gamma release assay test performs well in routine screening for tuberculosis

    DEFF Research Database (Denmark)

    Vestergaard Danielsen, Allan; Fløe, Andreas; Lillebæk, Troels

    2014-01-01

    Introduction: A positive interferon-gamma release assay (IGRA) is regarded as proof of latent Mycobacterium tuberculosis infection. We conducted an evaluation of the IGRA test “T-SPOT.TB” to test its performance during clinical routine use by analysing the positivity rate and odds, effect of season...... and sensitivity. Material and methods: Data from T-SPOT.TB testing together with age and test indications (anti-tumour necrosis factor alpha (TNFα) candidate, contact investigation or suspicion of tuberculosis (TB)) were combined with mycobac­teria culture results. Results: A total of 1,809 patients were tested....... Conclusive results were achieved for 1,780 patients (98.4%). Among these, 4.6% of anti-TNFα candidates, 19.3% of contacts and 24.4% of TB suspects tested positive. Compared with anti-TNFα candidates, the odds for a positive result were significantly higher for contact investigations (odds ratio (OR), mean...

  5. High-performance liquid chromatographic assay for the determination of Aloe Emodin in mouse plasma.

    Science.gov (United States)

    Zaffaroni, M; Mucignat, C; Pecere, T; Zagotto, G; Frapolli, R; D'Incalci, M; Zucchetti, M

    2003-10-25

    An isocratic high-performance liquid chromatography (HPLC) method was developed and validated to determine Aloe Emodin (AE) in mouse plasma. The analysis required 0.3 ml of plasma and involves extraction with dichloromethane. The HPLC separation was carried out on Symmetry Shield RP18, a mobile phase of methanol-water-acetic acid (65:35:0.2) and fluorescence detection at lambda(ex)=410 nm and lambda(em)=510 nm. The retention time of AE was 11.7 min. The assay was linear from 10 to 1,000 ng/ml (r2 > or = 0.999), showed intra- and inter-day precision within 7.8 and 4.7%, and accuracy of 87.3-105.7%. Detection limit (LOD) and quantification limit (LOQ) were 4.5 and 5 ng/ml, respectively. The method was applied to determine for the first time the pharmacokinetic of AE in mice.

  6. Effects of β-glucan polysaccharide revealed by the dominant lethal assay and micronucleus assays, and reproductive performance of male mice exposed to cyclophosphamide

    Directory of Open Access Journals (Sweden)

    Rodrigo Juliano Oliveira

    2014-01-01

    Full Text Available β-glucan is a well-known polysaccharide for its chemopreventive effect. This study aimed to evaluate the chemopreventive ability of β-glucan in somatic and germ cells through the dominant lethal and micronucleus assays, and its influence on the reproductive performance of male mice exposed to cyclophosphamide. The results indicate that β-glucan is capable of preventing changes in DNA in both germ cells and somatic ones. Changes in germ cells were evaluated by the dominant lethal assay and showed damage reduction percentages of 46.46% and 43.79% for the doses of 100 and 150 mg/kg. For the somatic changes, evaluated by micronucleus assay in peripheral blood cells in the first week of treatment, damage reduction percentages from 80.63-116.32% were found. In the fifth and sixth weeks, the percentage ranged from 10.20-52.54% and -0.95-62.35%, respectively. Besides the chemopreventive efficiency it appears that the β-glucan, when combined with cyclophosphamide, is able to improve the reproductive performance of males verified by the significant reduction in rates of post-implantation losses and reabsorption in the mating of nulliparous females with males treated with cyclophosphamide.

  7. Performance Demonstration Program Plan for Nondestructive Assay of Boxed Wastes for the TRU Waste Characterization Program

    International Nuclear Information System (INIS)

    2001-01-01

    The Performance Demonstration Program (PDP) for nondestructive assay (NDA) consists of a series of tests to evaluate the capability for NDA of transuranic (TRU) waste throughout the Department of Energy (DOE) complex. Each test is termed a PDP cycle. These evaluation cycles provide an objective measure of the reliability of measurements obtained from NDA systems used to characterize the radiological constituents of TRU waste. The primary documents governing the conduct of the PDP are the Waste Acceptance Criteria for the Waste Isolation Pilot Plant (WAC; DOE 1999a) and the Quality Assurance Program Document (QAPD; DOE 1999b). The WAC requires participation in the PDP; the PDP must comply with the QAPD and the WAC. The WAC contains technical and quality requirements for acceptable NDA. This plan implements the general requirements of the QAPD and applicable requirements of the WAC for the NDA PDP for boxed waste assay systems. Measurement facilities demonstrate acceptable performance by the successful testing of simulated waste containers according to the criteria set by this PDP Plan. Comparison among DOE measurement groups and commercial assay services is achieved by comparing the results of measurements on similar simulated waste containers reported by the different measurement facilities. These tests are used as an independent means to assess the performance of measurement groups regarding compliance with established quality assurance objectives (QAO's). Measurement facilities must analyze the simulated waste containers using the same procedures used for normal waste characterization activities. For the boxed waste PDP, a simulated waste container consists of a modified standard waste box (SWB) emplaced with radioactive standards and fabricated matrix inserts. An SWB is a waste box with ends designed specifically to fit the TRUPACT-II shipping container. SWB's will be used to package a substantial volume of the TRU waste for disposal. These PDP sample components

  8. Performance characteristics of SCC radioimmunoassay and clinical significance serum SCC Ag assay in patients with malignancy

    International Nuclear Information System (INIS)

    Kim, Dong Youn

    1986-01-01

    To evaluate the performance characteristics of SCC RIV and the clinical significance of serum SCC Ag assay in patients with malignancy, serum SCC Ag levels were measured by SCC RIV kit in 40 normal controls and 35 percents with various untreated malignancy, who visited Chonju Presbyterian Medical Center. The results were as follows; 1. The SCC RIA was simple to perform and can be completed in two workday. And the standard curve and reproducibility were both good. 2. The mean serum SCC Ag level in normal controls was 1.64 ± 0.93 ng/mL and normal upper limit of serum SCC Ag was defined as 2.6 ng/mL. 3 out of 40 (7.5%) normal controls showed elevated SCC Ag levels above the normal upper limit. 3. In 35 patients with various untreated malignancy, 18 patients (51.4%) showed elevated serum SCC Ag levels, 59.1% of 22 patients with cervical cancer, 80% of 5 patients with lung cancer, 33% of 3 patients with esophageal cancer, 0% of 2 patients with rectal cancer and 0% of 3 patients with breast cancer showed elevated serum SCC Ag levels. Above results represent that SCC RIV is simple method to perform followed by good standard curve and reproducibility, and may be a useful indicator reflecting diagnostic data of patients with cervical cancer and lung cancer

  9. Basic Evaluation of Analytical Performance and Clinical Utility of Immunoradiometric TSH Assay

    International Nuclear Information System (INIS)

    Suhy, Il Kyo; Cho, Bo Youn; Lee, Hong Kyu; Koh, Chang Soon; Min, Hun Ki; Lee, Mun Ho

    1987-01-01

    To assess the analytic performance of immunoradiometric TSH assay (IRMA TSH), assay precision determined by intra and interassay variance, assay accuracy determined by dilution and recovery study, were evaluated by using two commercial kit (Abott and Daichi). Normal range of basal serum TSH and TRH stimulated TSH increment were also determined in 234 healthy subjects (male 110, female 124; age 20-70) and 30 volunteers (male 10, female 20; age 21-26). In addition, basal TSH levels of 70 patients with untreated hyperthyroidism, 50 untreated hypothyroidism, and 60 euthyroidism were measured to assess the clinical utility of IRMA TSH. The detection limit of IRMA TSH was 0.04 mU/l and 0.08 mU/l by Abott Kit and Daichi kit respectively. Using Abott kit, intraassay variance were 2.0, 3.1 and 1.4% in mean TSH concentration 2.4, 31.6 and 98.2 mU/l repectively and interassay variance were 2.0 and 3.2% in mean TSH concentration 2.3 and 31.3 mU/l. Mean recovery rate was 92.5% and dilution study showed nearly straight line. When Daichi kit was used, intrasssay variance were 5.6, 5.2 and 6.2% in mean TSH concentration of 2.4, 31.6 and 98.2 mU/1 respectively and interassay variance were 7.1 and 7.4% in mean TSH of 2.3 and 31.3 mU,/l. Mean recovery rate was 89.9%. Normal range of basal TSH and TRH stimulated peak TSH were 0.38-4.02 mU/1 and 2.85-30.8 mU/1 repectively (95% confidence interval, Abott kit used). Sensitivity and specificity of basal TSH levels for diagnosing hypothyroidism as well as specificity for diagnosing hyperthyroidism were 100% by using both kit. Sensitivity of basal TSH level for diagnosing hyperthyroidism was 100% when TSH levels were measured by Abott kit while that was 80.9% when measured by Daichi kit. These results suggest that IRMA TSH was very precise and accurate method and might be used as a first line test in the evaluation of thyroid function

  10. Experience with local lymph node assay performance standards using standard radioactivity and nonradioactive cell count measurements.

    Science.gov (United States)

    Basketter, David; Kolle, Susanne N; Schrage, Arnhild; Honarvar, Naveed; Gamer, Armin O; van Ravenzwaay, Bennard; Landsiedel, Robert

    2012-08-01

    The local lymph node assay (LLNA) is the preferred test for identification of skin-sensitizing substances by measuring radioactive thymidine incorporation into the lymph node. To facilitate acceptance of nonradioactive variants, validation authorities have published harmonized minimum performance standards (PS) that the alternative endpoint assay must meet. In the present work, these standards were applied to a variant of the LLNA based on lymph node cell counts (LNCC) run in parallel as a control with the standard LLNA with radioactivity measurements, with threshold concentrations (EC3) being determined for the sensitizers. Of the 22 PS chemicals tested in this study, 21 yielded the same results from standard radioactivity and cell count measurements; only 2-mercaptobenzothiazole was positive by LLNA but negative by LNCC. Of the 16 PS positives, 15 were positive by LLNA and 14 by LNCC; methylmethacrylate was not identified as sensitizer by either of the measurements. Two of the six PS negatives tested negative in our study by both LLNA and LNCC. Of the four PS negatives which were positive in our study, chlorobenzene and methyl salicylate were tested at higher concentrations than the published PS, whereas the corresponding concentrations resulted in consistent negative results. Methylmethacrylate and nickel chloride tested positive within the concentration range used for the published PS. The results indicate cell counts and radioactive measurements are in good accordance within the same LLNA using the 22 PS test substances. Comparisons with the published PS results may, however, require balanced analysis rather than a simple checklist approach. Copyright © 2011 John Wiley & Sons, Ltd.

  11. Translating tumor biology into personalized treatment planning: analytical performance characteristics of the Oncotype DX® Colon Cancer Assay

    International Nuclear Information System (INIS)

    Clark-Langone, Kim M; Sangli, Chithra; Krishnakumar, Jayadevi; Watson, Drew

    2010-01-01

    The Oncotype DX ® Colon Cancer Assay is a new diagnostic test for determining the likelihood of recurrence in stage II colon cancer patients after surgical resection using fixed paraffin embedded (FPE) primary colon tumor tissue. Like the Oncotype DX Breast Cancer Assay, this is a high complexity, multi-analyte, reverse transcription (RT) polymerase chain reaction (PCR) assay that measures the expression levels of specific cancer-related genes. By capturing the biology underlying each patient's tumor, the Oncotype DX Colon Cancer Assay provides a Recurrence Score (RS) that reflects an individualized risk of disease recurrence. Here we describe its analytical performance using pre-determined performance criteria, which is a critical component of molecular diagnostic test validation. All analytical measurements met pre-specified performance criteria. PCR amplification efficiency for all 12 assays was high, ranging from 96% to 107%, while linearity was demonstrated over an 11 log 2 concentration range for all assays. Based on estimated components of variance for FPE RNA pools, analytical reproducibility and precision demonstrated low SDs for individual genes (0.16 to 0.32 C T s), gene groups (≤0.05 normalized/aggregate C T s) and RS (≤1.38 RS units). Analytical performance characteristics shown here for both individual genes and gene groups in the Oncotype DX Colon Cancer Assay demonstrate consistent translation of specific biology of individual tumors into clinically useful diagnostic information. The results of these studies illustrate how the analytical capability of the Oncotype DX Colon Cancer Assay has enabled clinical validation of a test to determine individualized recurrence risk after colon cancer surgery

  12. Translating tumor biology into personalized treatment planning: analytical performance characteristics of the Oncotype DX® Colon Cancer Assay

    Directory of Open Access Journals (Sweden)

    Krishnakumar Jayadevi

    2010-12-01

    Full Text Available Abstract Background The Oncotype DX® Colon Cancer Assay is a new diagnostic test for determining the likelihood of recurrence in stage II colon cancer patients after surgical resection using fixed paraffin embedded (FPE primary colon tumor tissue. Like the Oncotype DX Breast Cancer Assay, this is a high complexity, multi-analyte, reverse transcription (RT polymerase chain reaction (PCR assay that measures the expression levels of specific cancer-related genes. By capturing the biology underlying each patient's tumor, the Oncotype DX Colon Cancer Assay provides a Recurrence Score (RS that reflects an individualized risk of disease recurrence. Here we describe its analytical performance using pre-determined performance criteria, which is a critical component of molecular diagnostic test validation. Results All analytical measurements met pre-specified performance criteria. PCR amplification efficiency for all 12 assays was high, ranging from 96% to 107%, while linearity was demonstrated over an 11 log2 concentration range for all assays. Based on estimated components of variance for FPE RNA pools, analytical reproducibility and precision demonstrated low SDs for individual genes (0.16 to 0.32 CTs, gene groups (≤0.05 normalized/aggregate CTs and RS (≤1.38 RS units. Conclusions Analytical performance characteristics shown here for both individual genes and gene groups in the Oncotype DX Colon Cancer Assay demonstrate consistent translation of specific biology of individual tumors into clinically useful diagnostic information. The results of these studies illustrate how the analytical capability of the Oncotype DX Colon Cancer Assay has enabled clinical validation of a test to determine individualized recurrence risk after colon cancer surgery.

  13. Translating tumor biology into personalized treatment planning: analytical performance characteristics of the Oncotype DX Colon Cancer Assay.

    Science.gov (United States)

    Clark-Langone, Kim M; Sangli, Chithra; Krishnakumar, Jayadevi; Watson, Drew

    2010-12-23

    The Oncotype DX Colon Cancer Assay is a new diagnostic test for determining the likelihood of recurrence in stage II colon cancer patients after surgical resection using fixed paraffin embedded (FPE) primary colon tumor tissue. Like the Oncotype DX Breast Cancer Assay, this is a high complexity, multi-analyte, reverse transcription (RT) polymerase chain reaction (PCR) assay that measures the expression levels of specific cancer-related genes. By capturing the biology underlying each patient's tumor, the Oncotype DX Colon Cancer Assay provides a Recurrence Score (RS) that reflects an individualized risk of disease recurrence. Here we describe its analytical performance using pre-determined performance criteria, which is a critical component of molecular diagnostic test validation. All analytical measurements met pre-specified performance criteria. PCR amplification efficiency for all 12 assays was high, ranging from 96% to 107%, while linearity was demonstrated over an 11 log2 concentration range for all assays. Based on estimated components of variance for FPE RNA pools, analytical reproducibility and precision demonstrated low SDs for individual genes (0.16 to 0.32 CTs), gene groups (≤ 0.05 normalized/aggregate CTs) and RS (≤ 1.38 RS units). Analytical performance characteristics shown here for both individual genes and gene groups in the Oncotype DX Colon Cancer Assay demonstrate consistent translation of specific biology of individual tumors into clinically useful diagnostic information. The results of these studies illustrate how the analytical capability of the Oncotype DX Colon Cancer Assay has enabled clinical validation of a test to determine individualized recurrence risk after colon cancer surgery.

  14. Brief Report: Impact of Early Antiretroviral Therapy on the Performance of HIV Rapid Tests and HIV Incidence Assays.

    Science.gov (United States)

    Fogel, Jessica M; Piwowar-Manning, Estelle; Debevec, Barbara; Walsky, Tamara; Schlusser, Katherine; Laeyendecker, Oliver; Wilson, Ethan A; McCauley, Marybeth; Gamble, Theresa; Tegha, Gerald; Soko, Dean; Kumwenda, Johnstone; Hosseinipour, Mina C; Chen, Ying Q; Cohen, Myron S; Eshleman, Susan H

    2017-08-01

    Antiretroviral therapy (ART) can downregulate antibody responses to HIV infection. We evaluated the impact of early vs. delayed ART on the performance of HIV diagnostic and incidence assays. Samples were obtained from 207 participants in the HPTN 052 trial, who were stably suppressed on ART for ≥4 years [Malawi sites; pre-ART CD4 cell count 350-550 cells/mm (early ART arm, N = 180) or ART arm, N = 27)]. Samples were tested with 2 HIV rapid tests and 2 HIV incidence assays; selected samples were also tested with two fourth-generation immunoassays and a Western blot (WB) assay. A pre-ART sample was analyzed if the follow-up sample had a false-negative or weakly-reactive rapid test result, or had an incidence assay result indicative of recent infection (false-recent result). Ten (4.8%) samples had a nonreactive or weakly-reactive rapid test result (7/180 early ART arm, 3/27 delayed ART arm, P = 0.13); one sample had nonreactive fourth-generation assay results and 3 had indeterminate WBs. Forty (18.9%) samples had a false-recent incidence assay result; 16 (7.8%) had false-recent results with both incidence assays. Baseline samples had stronger rapid test and WB bands, higher fourth-generation assay signal-to-cutoff values, and fewer HIV incidence assay results indicative of recent infection. False-negative/weakly-reactive HIV rapid tests and false-recent HIV incidence assay results were observed in virally-suppressed individuals, regardless of pre-ART CD4 cell count. Downregulation of the antibody response to HIV infection in the setting of ART may impact population-level surveys of HIV prevalence and incidence.

  15. Performance Demonstration Program Plan for Nondestructive Assay of Drummed Wastes for the TRU Waste Characterization Program

    International Nuclear Information System (INIS)

    2005-01-01

    The Performance Demonstration Program (PDP) for Nondestructive Assay (NDA) is a test program designed to yield data on measurement system capability to characterize drummed transuranic (TRU) waste generated throughout the Department of Energy (DOE) complex. The tests are conducted periodically and provide a mechanism for the independent and objective assessment of NDA system performance and capability relative to the radiological characterization objectives and criteria of the Office of Characterization and Transportation (OCT). The primary documents requiring an NDA PDP are the Waste Acceptance Criteria for the Waste Isolation Pilot Plant (WAC), which requires annual characterization facility participation in the PDP, and the Quality Assurance Program Document (QAPD). This NDA PDP implements the general requirements of the QAPD and applicable requirements of the WAC. Measurement facilities must demonstrate acceptable radiological characterization performance through measurement of test samples comprised of pre-specified PDP matrix drum/radioactive source configurations. Measurement facilities are required to analyze the NDA PDP drum samples using the same procedures approved and implemented for routine operational waste characterization activities. The test samples provide an independent means to assess NDA measurement system performance and compliance per criteria delineated in the NDA PDP Plan. General inter-comparison of NDA measurement system performance among DOE measurement facilities and commercial NDA services can also be evaluated using measurement results on similar NDA PDP test samples. A PDP test sample consists of a 55-gallon matrix drum containing a waste matrix type representative of a particular category of the DOE waste inventory and nuclear material standards of known radionuclide and isotopic composition typical of DOE radioactive material. The PDP sample components are made available to participating measurement facilities as designated by the

  16. Comparison of the performance of IFA, CFA, and ELISA assays for the serodiagnosis of acute Q fever by quality assessment.

    Science.gov (United States)

    Herremans, Tineke; Hogema, Boris M; Nabuurs, Marrigje; Peeters, Marcel; Wegdam-Blans, Marjolijn; Schneeberger, Peter; Nijhuis, Carla; Notermans, Daan W; Galama, Joep; Horrevorts, Anton; van Loo, Inge H M; Vlaminckx, Bart; Zaaijer, Hans L; Koopmans, Marion P; Berkhout, Hanneke; Socolovschi, Cristina; Raoult, Didier; Stenos, John; Nicholson, William; Bijlmer, Henk

    2013-01-01

    The indirect immunofluorescence assay (IFA) is considered the reference method for diagnosing Q fever, but serology is also performed by complement fixation assay (CFA) or enzyme-linked immunosorbent assay (ELISA). However, comparability between these assays is not clear, and therefore a quality assessment was performed. A total of 25 serum samples from negative controls, Q fever patients, and a serial diluted high-positive sample were analyzed in 10 Dutch laboratories. Six laboratories performed CFA, 5 performed IFA, and 5 performed ELISAs. Three international reference laboratories from Australia, France, and the USA also participated in this study. Qualitative values between laboratories using the same methods were within close range, and all 3 methods correctly identified acute Q fever patients. The IFA, ELISA, and CFA are all suitable serodiagnostic assays to diagnose acute Q fever, but the IFA remains an important tool in the follow-up of patients and in identifying patients at risk for developing chronic Q fever. Copyright © 2013 Elsevier Inc. All rights reserved.

  17. Analytical and clinical performance of thyroglobulin autoantibody assays in thyroid cancer follow-up.

    Science.gov (United States)

    Katrangi, Waddah; Grebe, Stephan K G; Algeciras-Schimnich, Alicia

    2017-10-26

    While thyroglobulin autoantibodies (TgAb) can result in false low serum thyroglobulin (Tg) immunoassay (IA) measurements, they might also be indicators of disease persistence/recurrence. Hence, accurate TgAb measurement, in addition to Tg quantification, is crucial for thyroid cancer monitoring. We compared the analytical and clinical performance of four commonly used TgAb IAs. We measured Tg by mass spectrometry (Tg-MS) and by four pairs of Tg and TgAb IAs (Beckman, Roche, Siemens, Thermo) in 576 samples. Limit of quantitation (LOQ) and manufacturers' upper reference interval cut-off (URI) were used for comparisons. Clinical performance was assessed by receiving operator characteristics (ROC) curve analysis. Quantitative and qualitative agreement between TgAb-IAs was moderate with R2 of 0.20-0.70 and κ from 0.41-0.66 using LOQ and 0.47-0.71 using URI. In samples with TgAb interference, detection rates of TgAb were similar using LOQ and URI for Beckman, Siemens, and Thermo, but much lower for the Roche TgAb-IA when the URI was used. In TgAb positive cases, the ROC areas under the curve (AUC) for the TgAb-IAs were 0.59 (Beckman), 0.62 (Siemens), 0.59 (Roche), and 0.59 (Thermo), similar to ROC AUCs achieved with Tg. Combining Tg and TgAb measurements improved the ROC AUCs compared to Tg or TgAb alone. TgAb-IAs show significant qualitative and quantitative differences. For 2 of the 4 TgAb-IAs, using the LOQ improves the detection of interfering TgAbs. All assays showed suboptimal clinical performance when used as surrogate markers of disease, with modest improvements when Tg and TgAb were combined.

  18. Analytical evaluation of Lumipulse® BRAHMS PCT CLEIA assay and clinical performances in an unselected population as compared with central lab PCT assay.

    Science.gov (United States)

    Dupuy, Anne Marie; Né, Maxence; Bargnoux, Anne Sophie; Badiou, Stéphanie; Cristol, Jean Paul

    2017-03-01

    We report the analytical performances of the Lumipulse®G BRAHMS PCT assay (Fujirebio, Courteboeuf, France) and the concordance with BRAHMS PCT Kryptor CompactPlus© results from central laboratory. Lumipulse®G BRAHMS PCT immunoassay on Lumipulse®G600II instrument is a chemiluminescence enzyme immunoassay (CLEIA). Analytical performances included imprecision study, linearity, limit of detection and comparison study on 138 plasma specimen on Lumipulse®G600II vs plasma on Kryptor CompactPlus©. The intra and inter assay imprecision of Lumipulse®G BRAHMS PCT was between 2 and 5%. The LoD in our condition was 0.0029ng/mL in accordance with the LoD provided by the manufacturer (0.0048ng/mL). The linear equation of linearity was y=1,001×-0,052 with r 2 =0.99, with a mean recovery (SD) percentage of 1.8% (8%). Correlation studies showed a good correlation (r=0.99) between plasma on Kryptor and Lumipulse, with a bias of 0.02 in the range from 0.12 to 1ng/mL. The new adaptation developed from Fujirebio on quantification of PCT with CLEIA technology from monoclonal antibodies from ThermoFisher appears to be acceptable for clinical use. Copyright © 2016 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.

  19. Diagnostic performance of a commercial immunoblot assay for myositis antibody testing.

    Science.gov (United States)

    Bundell, Chris; Rojana-Udomsart, Arada; Mastaglia, Frank; Hollingsworth, Peter; McLean-Tooke, Andrew

    2016-06-01

    The objective of this study was to establish a population based reference range for a commercial immunoblot assay detecting myositis specific autoantibodies (MSAs) and myositis associated autoantibodies (MAAs), and to assess the diagnostic performance of this reference range against the manufacturer's recommended ranges in a myositis patient cohort. A total of 124 patients from a myositis cohort and 197 healthy controls were serologically assessed using a commercial immunoblot containing eleven autoantigens (Jo-1, EJ, OJ, PL7, PL12, Mi-2, SRP, Ku, PMScl75, PMScl100 and Ro52) according to the manufacturer's instructions. Use of the manufacturer's reference ranges resulted in detection of MSAs in 19.4% of myositis patients and 9.1% of controls; MAAs were detected in 41.1% of myositis patients and 14.2% of controls. Reference values derived from the healthy control population resulted in significant differences in cut-off values for some autoantibodies, particularly Ro52 and PMScl75. Use of local reference ranges reduced detection of MSAs to 16.9% of myositis patients and 3% of healthy controls, with MAAs 23.4% of patients and 2% of healthy controls. Application of population based reference ranges resulted in significant differences in detection of MSAs and MAAs compared to the manufacturer's recommended ranges. Cut-off levels should be assessed to ensure suitability for the population tested. Copyright © 2016. Published by Elsevier B.V.

  20. High-performance liquid chromatographic assay for genistein in biological fluids.

    Science.gov (United States)

    Supko, J G; Phillips, L R

    1995-04-07

    A specific, sensitive and technically convenient HPLC method for assaying genistein in biological fluids has been developed. The compound and 4-hydroxybenzophenone, added as an internal standard, were efficiently isolated from both plasma and urine by extraction with tert-butyl methyl ether. Following evaporation of the organic solvent, the extract was reconstituted with methanol-0.05 M ammonium acetate buffer, pH 4.7 (30:70, v/v), and loaded onto a 4 microns Nova-Pak C8 column (15 cm x 3.9 mm I.D.). Chromatography was performed at ambient temperature using a mobile phase of acetonitrile-0.05 M ammonium formate buffer, pH 4.0 (27:73, v/v), at a flow-rate of 1.0 ml/min, with UV detection at 260 nm. Mean values of the tR for the drug and internal standard, determined from chromatograms of the 1 microgram/ml plasma standard during a 6 month period, were 8.27 +/- 0.55 and 11.92 +/- 0.71 min, respectively (S.D., n = 29). With a sample volume of 50 microliters, the lowest concentration of genistein included in the plasma standard curve, 0.020 microgram/ml, was quantified with a 10.7% R.S.D. over a 5 month period. Plasma standards having concentrations of 0.050 to 1.02 micrograms/ml exhibited R.S.D. values ranging from 2.3 to 6.1%. The drug was quantified in urine with similar reproducibility. The sensitivity of the assay was adequate for characterizing the plasma pharmacokinetics of genistein in the mouse and dog. However, a 10-fold improvement in sensitivity was afforded by increasing the sample size to 250 microliters, without otherwise modifying the method. Thus, this procedure may prove suitable for determining plasma and urine levels of genistein in humans consuming dietary isoflavonoids in a much more convenient manner than permitted by existing methodology.

  1. Comparative Evaluation of the Diagnostic Performance of the Prototype Cepheid GeneXpert Ebola Assay

    Science.gov (United States)

    Jansen van Vuren, Petrus; Grobbelaar, Antoinette; Storm, Nadia; Conteh, Ousman; Konneh, Kelfala; Kamara, Abdul; Sanne, Ian

    2015-01-01

    The Ebola virus disease (EVD) outbreak in West Africa has highlighted an urgent need for point-of-care (POC) assays for the diagnosis of this devastating disease in resource-limited African countries. The diagnostic performance characteristics of a prototype Cepheid GeneXpert Ebola POC used to detect Ebola virus (EBOV) in stored serum and plasma samples collected from suspected EVD cases in Sierra Leone in 2014 and 2015 was evaluated. The GeneXpert Ebola POC is a self-contained single-cartridge automated system that targets the glycoprotein (GP) and nucleoprotein (NP) genes of EBOV and yields results within 90 min. Results from 281 patient samples were compared to the results of a TaqMan real-time reverse transcription-PCR (RT-PCR) targeting the polymerase gene and performed on two real-time PCR machines. Agreement between the three platforms was 100% at cycle threshold (CT) values of ≤34.99, but discordant results were noted between CT values of 35 and 45.The diagnostic sensitivity of the three platforms was 100% in 91 patient samples that were confirmed to be infectious by virus isolation. All three molecular platforms detected viral EBOV RNA in additional samples that did not contain viable EBOV. The analytical sensitivity of the GeneXpert Ebola POC for the detection of NP was higher, and comparable to that of polymerase gene detection, than that for the detection of GP when using a titrated laboratory stock of EBOV. There was no detectable cross-reactivity with other hemorrhagic fever viruses or arboviruses. The GeneXpert Ebola POC offers an easy to operate and sensitive diagnostic tool that can be used for the rapid screening of suspected EVD cases in treatment or in holding centers during EVD outbreaks. PMID:26637383

  2. Performance values for non destructive assay (NDA) techniques applied to safeguards: the 2002 evaluation by the ESARDA NDA Working Group

    International Nuclear Information System (INIS)

    Guardini, S.

    2003-01-01

    The first evaluation of NDA performance values undertaken by the ESARDA Working Group for Standards and Non Destructive Assay Techniques (WGNDA) was published in 1993. Almost 10 years later the Working Group decided to review those values, to report about improvements and to issue new performance values for techniques which were not applied in the early nineties, or were at that time only emerging. Non-Destructive Assay techniques have become more and more important in recent years, and they are used to a large extent in nuclear material accountancy and control both by operators and control authorities. As a consequence, the performance evaluation for NDA techniques is of particular relevance to safeguards authorities in optimising Safeguards operations and reducing costs. Performance values are important also for NMAC regulators, to define detection levels, limits for anomalies, goal quantities and to negotiate basic audit rules. This paper presents the latest evaluation of ESARDA Performance Values (EPVs) for the most common NDA techniques currently used for the assay of nuclear materials for Safeguards purposes. The main topics covered by the document are: techniques for plutonium bearing materials: PuO 2 and MOX; techniques for U-bearing materials; techniques for U and Pu in liquid form; techniques for spent fuel assay. This issue of the performance values is the result of specific international round robin exercises, field measurements and ad hoc experiments, evaluated and discussed in the ESARDA NDA Working Group. (author)

  3. Status of development and irradiation performance of advanced proliferation resistant MTR fuel at NUKEM

    International Nuclear Information System (INIS)

    Hrovat, M.; Hassel, H.-W.; Wehner, E.

    1985-01-01

    This paper describes the current status of development and irradiation performance of fuel elements for Material Test and Research (MTR) Reactors with Medium Enriched Uranium (MEU, ≤ 45 % 235-U) and Low Enriched Uranium (LEU, ≤ 20 % 235-U). (author)

  4. Assay of fluconazole by high-performance liquid chromatography with a mixed-phase column.

    OpenAIRE

    Wallace, J E; Harris, S C; Gallegos, J; Foulds, G; Chen, T J; Rinaldi, M G

    1992-01-01

    A mixed-phase liquid chromatographic column was used to assay fluconazole in plasma, serum, and cerebrospinal fluid. The assay was linear from 0.2 to 20 micrograms/ml, with an average coefficient of variation of less than 5%. The partitioning of the drug between serum and cerebrospinal fluid was determined for 34 patients. The method was demonstrated to be suitable for both pharmacokinetic studies and monitoring of patients receiving treatment with this antifungal agent.

  5. Comparison of Hemoglobin A1c assay performance on two different commercial systems

    Directory of Open Access Journals (Sweden)

    Jozo Ćorić

    2015-04-01

    Full Text Available Introduction: Glycated hemoglobin (HbA1c is formed by non-enzymatic binding of glucose to the free amino group of the N-terminal end of the ß-chain of hemoglobin A. HbA1c is representative of the mean blood glucose level over three months. The aim of the study was to evaluate the Hemoglobin A1c immunoturbidimetric assay performance on two different commercial systems.Methods: We evaluated the precision and trueness for determination of HbA1c in whole blood. Concentrations of total hemoglobin and HbA1c were evaluated on Dimension Xpand (Siemens and Cobas 501 (Roche analyzers. HbA1c was measured in a latex agglutination inhibition test. Commercial controls Liquichek Diabetes Control Level 1 and Liquichek Diabetes Control Level 2 (Bio Rad at two levels were used for quality control. Analytical validation of HbA1c included: within-run imprecision, between-day imprecision, inaccuracy and comparison determination on the human samples on 2 systems: Dimension Xpand and Cobas 501 analyzers. Results: Within-run imprecision on the commercially controls for Level 1 is 4.5% and Level 2 is 3.2% between-day imprecision on commercially controls is 6.1% Level 1 and 5.1% Level 2 for respectively inac- curacy on commercially controls for Level 1 is 1.8% and Level 2 is 4.8%. Method comparison on human samples shows the correlation coefficient of 0.99.Conclusion: The presented results of the analytical evaluation methods for the determination of HbA1c showed an acceptable accuracy and precision.

  6. Performance evaluation of the Cobas TaqMan MTB assay on respiratory specimens according to clinical application

    Directory of Open Access Journals (Sweden)

    Jong Eun Park

    2017-11-01

    Full Text Available Objective: To evaluate the performance of the Cobas TaqMan MTB assay (Cobas assay with respect to its clinical application. Methods: This was a retrospective analysis of 1154 results from 1034 patients for whom mycobacterial cultures and the Cobas assay were performed simultaneously. Based on the patient medical records, two categories of clinical application were defined: (1 the diagnosis of patients with a high probability of pulmonary tuberculosis according to clinical and radiological features (n = 128, and (2 the exclusion of tuberculosis in clinically indeterminate patients (n = 1026. Standard culture was used as the reference method. Results: The sensitivity of the Cobas assay for the detection of Mycobacterium tuberculosis was 70.4% (95% confidence interval (CI 49.7–85.5% for category 1, but only 25.0% (95% CI 4.5–64.4% for category 2. The specificity was ≥95.0% for both categories. The positive predictive value was 79.2% (95% CI 57.3–92.1% for category 1 and 33.3% (95% CI 6.0–75.9% for category 2, while the negative predictive value was 92.3% (95% CI 85.0–96.4% for category 1 and 99.4% (95% CI 98.7–99.8% for category 2. Conclusions: The results of this study indicate that Cobas assay results must be interpreted carefully according to the clinical purpose of the assay. Keywords: Mycobacterium tuberculosis, Pulmonary tuberculosis, Cobas TaqMan MTB assay, Korea

  7. High-performance liquid chromatography-mass spectrometry-based acetylcholinesterase assay for the screening of inhibitors in natural extracts

    NARCIS (Netherlands)

    de Jong, C.F.; Derks, R.J.E.; Bruyneel, B.; Niessen, W.M.A.; Irth, H.

    2006-01-01

    The present paper describes a High-performance liquid chromatography-mass spectrometry (LC-MS) methodology for the screening of acetylcholinesterase (AChE) inhibitors in natural extracts. AChE activity of sample components is monitored by a post-column biochemical assay that is based on the

  8. Performance evaluation of the Elecsys syphilis assay for the detection of total antibodies to Treponema pallidum.

    Science.gov (United States)

    Enders, Martin; Hunjet, Andrea; Gleich, Michael; Imdahl, Roland; Mühlbacher, Annelies; Schennach, Harald; Chaiwong, Kriangsak; Sakuldamrongpanich, Tasanee; Turhan, Ajda; Sertöz, Rüchan; Wolf, Eva; Mayer, Wolfgang; Tao, Chuanmin; Wang, Lan Lan; Semprini, Simona; Sambri, Vittorio

    2015-01-01

    Syphilis is a health problem of increasing incidence in recent years that may have severe complications if not diagnosed and treated at an early stage. There are many diagnostic tests available for syphilis, but there is no gold standard, and diagnosis therefore usually relies upon a combination of tests. In this multicenter study, we evaluated the treponemal Elecsys syphilis assay for use in the diagnosis of syphilis in routine samples, i.e., when syphilis is suspected or during antenatal or blood donation screening. The sensitivity and specificity of the Elecsys syphilis assay were compared head to head with those of other treponemal assays used in routine clinical practice and were assessed in potentially cross-reactive samples from patients with Epstein-Barr virus, HIV, and Lyme disease. In a total of 8,063 syphilis-negative samples collected from routine diagnostic requests and blood donations, the Elecsys syphilis assay had a specificity of 99.88%. In 928 samples previously identified as syphilis positive, the sensitivity was 99.57 to 100% (the result is presented as a range depending on whether four initially indeterminate samples are included in the assessment). The specificity of the Elecsys syphilis assay in patients with other infections was 100%; no false-positive samples were identified. Copyright © 2015, American Society for Microbiology. All Rights Reserved.

  9. Performance evaluation of FlowCytomix assays to quantify cytokines in patients with rheumatoid arthritis

    Science.gov (United States)

    Wang, Xuefeng; Dong, Liyang; Liang, Yong; Ni, Hongchang; Tang, Jun; Xu, Chengcheng; Zhou, Yuepeng; Su, Yuting; Wang, Jun; Chen, Deyu; Mao, Chaoming

    2015-01-01

    Objectives: To compare the cytokine profile in RA patients and healthy control by using two methods-FlowCytomix assay and traditional ELISA. Methods: Cytokine levels were evaluated by FlowCytomix assay and ELISA in serum and supernatants of peripheral blood mononuclear cells (PBMC) cultures with and without stimulation by phytohaemagglutinin (PHA). Results: The levels of IL-6, IL-1β, and TNF-α were significantly higher in sera of RA patients than those of healthy controls. The levels of IL-22, IL-6, IL-1β, TNF-α, and IL-10 were higher in unstimulated PBMC culture supernatant of RA patients than those of healthy controls. PHA stimulation significantly increased the production of proinflammatory cytokines from PBMC with RA patients. Compared with detectable cytokine levels in sera, cytokine concentration in the supernatant of PBMCs was remarkably higher. FlowCytomix and ELISA showed significant correlation in detecting cytokines. However, the FlowCytomix assay detected more cytokines than ELISA. Conclusion: The supernatant of PBMCs provide a fine condition for the study of cytokine production because of the lack of interference factors in sera. The FlowCytomix assay is more sensitive than ELISA in detecting cytokines from RA patients. Multiple cytokine signatures using FlowCytomix assay may represent a more realistic approach in the future of personalized medicine in RA. PMID:26629129

  10. Performance Evaluation of the Elecsys Syphilis Assay for the Detection of Total Antibodies to Treponema pallidum

    Science.gov (United States)

    Enders, Martin; Hunjet, Andrea; Gleich, Michael; Imdahl, Roland; Mühlbacher, Annelies; Schennach, Harald; Chaiwong, Kriangsak; Sakuldamrongpanich, Tasanee; Turhan, Ajda; Sertöz, Rüchan; Wolf, Eva; Mayer, Wolfgang; Tao, Chuanmin; Wang, Lan Lan; Semprini, Simona

    2014-01-01

    Syphilis is a health problem of increasing incidence in recent years that may have severe complications if not diagnosed and treated at an early stage. There are many diagnostic tests available for syphilis, but there is no gold standard, and diagnosis therefore usually relies upon a combination of tests. In this multicenter study, we evaluated the treponemal Elecsys syphilis assay for use in the diagnosis of syphilis in routine samples, i.e., when syphilis is suspected or during antenatal or blood donation screening. The sensitivity and specificity of the Elecsys syphilis assay were compared head to head with those of other treponemal assays used in routine clinical practice and were assessed in potentially cross-reactive samples from patients with Epstein-Barr virus, HIV, and Lyme disease. In a total of 8,063 syphilis-negative samples collected from routine diagnostic requests and blood donations, the Elecsys syphilis assay had a specificity of 99.88%. In 928 samples previously identified as syphilis positive, the sensitivity was 99.57 to 100% (the result is presented as a range depending on whether four initially indeterminate samples are included in the assessment). The specificity of the Elecsys syphilis assay in patients with other infections was 100%; no false-positive samples were identified. PMID:25355799

  11. New high-performance liquid chromatography assay for glycosyltransferases based on derivatization with anthranilic acid and fluorescence detection.

    Science.gov (United States)

    Anumula, Kalyan Rao

    2012-07-01

    Assays were developed using the unique labeling chemistry of 2-aminobenzoic acid (2AA; anthranilic acid, AA) for measuring activities of both β1-4 galactosyltransferase (GalT-1) and α2-6 sialyltransferase (ST-6) by high-performance liquid chromatography (HPLC) with fluorescence detection (Anumula KR. 2006. Advances in fluorescence derivatization methods for high-performance liquid chromatographic analysis of glycoprotein carbohydrates. Anal Biochem. 350:1-23). N-Acetylglucosamine (GlcNAc) and N-acetyllactosamine were used as acceptors and uridine diphosphate (UDP)-galactose and cytidine monophosphate (CMP)-N-acetylneuraminic acid (NANA) as donors for GalT-1 and ST-6, respectively. Enzymatic products were labeled in situ with AA and were separated from the substrates on TSKgel Amide 80 column using normal-phase conditions. Enzyme units were determined from the peak areas by comparison with the concomitantly derivatized standards Gal-β1-4GlcNAc and NANA-α2-6 Gal-β1-4GlcNAc. Linearity (time and enzyme concentration), precision (intra- and interassay) and reproducibility for the assays were established. The assays were found to be useful in monitoring the enzyme activities during isolation and purification. The assays were highly sensitive and performed equal to or better than the traditional radioactive sugar-based measurements. The assay format can also be used for measuring the activity of other transferases, provided that the carbohydrate acceptors contain a reducing end for labeling. An assay for glycoprotein acceptors was developed using IgG. A short HPLC profiling method was developed for the separation of IgG glycans (biantennary G0, G1, G2, mono- and disialylated), which facilitated the determination of GalT-1 and ST-6 activities in a rapid manner. Furthermore, this profiling method should prove useful for monitoring the changes in IgG glycans in clinical settings.

  12. [Comparison of the clinical performance of the ECLusys HIV combi assay with the Lumipulse f and HISCL 2000-i HIV-1/2 ab screening assays].

    Science.gov (United States)

    Sugiura, Aya; Iwahara, Kunihiro; Suga, Yasuyuki; Uchiyama, Sachinori; Maekawa, Masato

    2012-04-01

    We compared the ECLusys HIV combi assay (ECL HIV Ag/Ab) to the Lumipulse Forte (LPf HIV 1/2 Ab) and HISCL (HIS HIV 1/2 Ab) assays. In a dilution sensitivity test using dilution panels of WHO HIV antibody international reference panel (HIV-1 Subtype A, B, C, E, HIV-1 Group O, HIV-2) and HIV-1/2 Ab CE marked material(HIV-1, HIV-2) parent specimens, the ECL assay enabled detection at a higher level of sensitivity than either the LPf assay or the HIS assay for all dilution panels. In an early detection test in the early phase of infection in which a BBI HIV seroconversion panel was used, the ECL assay enabled detection 7 days after initial blood sample collection, whereas the LPf and HIS assays enabled detection after 27 days. In a specificity test using high RF positive specimens (n=33), pregnancy specimens (n=35), cytomegalovirus antibody positive specimens (n=36), and high M protein positive specimens (n=21) that were confirmed negative for HIV-1/2 antibodies by the LPf assay, negative results were obtained for all specimens on both the ECL assay and the HIS assay. In a correlation test using routinely collected clinical specimens (n=121), including positive stock specimens, the ECL and HIS assays demonstrated the highest agreement rate 98.3%. The above results confirmed that the fourth-generation reagent ECL assay, which simultaneously detects both HIV-1/2 antibodies and p24 antigens, is both highly sensitive and specific, and is a suitable assay for use in routine testing.

  13. Performance assessment of self-interrogation neutron resonance densitometry for spent nuclear fuel assay

    Energy Technology Data Exchange (ETDEWEB)

    Hu, Jianwei, E-mail: huj1@ornl.gov [Reactor and Nuclear Systems Division, Oak Ridge National Laboratory, 1 Bethel Valley Road, PO Box 2008, MS-6172, Oak Ridge, TN 37831-6172 (United States); Tobin, Stephen J.; LaFleur, Adrienne M.; Menlove, Howard O.; Swinhoe, Martyn T. [Nuclear Engineering and Nonproliferation Division, Los Alamos National Laboratory (United States)

    2013-11-21

    Self-Interrogation Neutron Resonance Densitometry (SINRD) is one of several nondestructive assay (NDA) techniques being integrated into systems to measure spent fuel as part of the Next Generation Safeguards Initiative (NGSI) Spent Fuel Project. The NGSI Spent Fuel Project is sponsored by the US Department of Energy's National Nuclear Security Administration to measure plutonium in, and detect diversion of fuel pins from, spent nuclear fuel assemblies. SINRD shows promising capability in determining the {sup 239}Pu and {sup 235}U content in spent fuel. SINRD is a relatively low-cost and lightweight instrument, and it is easy to implement in the field. The technique makes use of the passive neutron source existing in a spent fuel assembly, and it uses ratios between the count rates collected in fission chambers that are covered with different absorbing materials. These ratios are correlated to key attributes of the spent fuel assembly, such as the total mass of {sup 239}Pu and {sup 235}U. Using count rate ratios instead of absolute count rates makes SINRD less vulnerable to systematic uncertainties. Building upon the previous research, this work focuses on the underlying physics of the SINRD technique: quantifying the individual impacts on the count rate ratios of a few important nuclides using the perturbation method; examining new correlations between count rate ratio and mass quantities based on the results of the perturbation study; quantifying the impacts on the energy windows of the filtering materials that cover the fission chambers by tallying the neutron spectra before and after the neutrons go through the filters; and identifying the most important nuclides that cause cooling-time variations in the count rate ratios. The results of these studies show that {sup 235}U content has a major impact on the SINRD signal in addition to the {sup 239}Pu content. Plutonium-241 and {sup 241}Am are the two main nuclides responsible for the variation in the count

  14. Radiochemical assay for determination of dihydropyrimidinase activity using reversed-phase high-performance liquid chromatography

    NARCIS (Netherlands)

    van Kuilenburg, A. B.; van Lenthe, H.; van Gennip, A. H.

    1999-01-01

    A radiochemical assay was developed to measure the activity of dihydropyrimidinase (DHP) in human liver homogenates. The method is based on the separation of radiolabeled dihydrouracil from N-carbamyl-beta-alanine by HPLC with on-line detection of radioactivity combined with detection of 14CO2 by

  15. Analytical performances of a new enzymatic assay for hemoglobin A1c.

    Science.gov (United States)

    Jaisson, Stéphane; Desmons, Aurore; Renard, Benoît; Chevelle, Benjamin; Leroy, Nathalie; Gillery, Philippe

    2014-07-01

    HbA1c is considered the gold standard for the follow-up of diabetic patients and a new diagnostic tool for diabetes mellitus, which implies the availability of reliable assay methods. We have evaluated a new assay developed by Abbott Laboratories, based on the enzymatic quantification of HbA1c by a fructosyl dipeptide oxidase using Architect analyzers. Precision, linearity, correlation with a HPLC method, accuracy and potential impact interferences on HbA1c measurement have been evaluated. Intra-day and between-day CVs were lower than 1.2% and linearity was excellent from 19 mmol/mol (3.9%) to 163 mmol/mol (17.1%). The results were well correlated with those obtained by the HPLC (Variant II device, kit NU - BioRad): HbA1c [Architect, mmol/mol]=0.986×HbA1c [Variant II, mmol/mol]+0.713 (r=0.998, n=109). This method provided consistent results with IFCC titrated quality control samples. Classical interferences in HbA1c assays (i.e. labile HbA1c, carbamylated hemoglobin, triglycerides or bilirubin) did not have an impact on HbA1c quantification by this method. This new enzymatic assay proved to be a robust and reliable method for HbA1c measurement suitable for routine practice in clinical chemistry laboratories. Copyright © 2014 Elsevier B.V. All rights reserved.

  16. A sensitive high performance liquid chromatography assay for the quantification of doxorubicin associated with DNA in tumor and tissues.

    Science.gov (United States)

    Lucas, Andrew T; O'Neal, Sara K; Santos, Charlene M; White, Taylor F; Zamboni, William C

    2016-02-05

    Doxorubicin, a widely used anticancer agent, exhibits antitumor activity against a wide variety of malignancies. The drug exerts its cytotoxic effects by binding to and intercalating within the DNA of tumor and tissue cells. However, current assays are unable to accurately determine the concentration of the intracellular active form of doxorubicin. Thus, the development of a sample processing method and a high-performance liquid chromatography (HPLC) methodology was performed in order to quantify doxorubicin that is associated with DNA in tumors and tissues, which provided an intracellular cytotoxic measure of doxorubicin exposure after administration of small molecule and nanoparticle formulations of doxorubicin. The assay uses daunorubicin as an internal standard; liquid-liquid phase extraction to isolate drug associated with DNA; a Shimadzu HPLC with fluorescence detection equipped with a Phenomenex Luna C18 (2μm, 2.0×100mm) analytical column and a gradient mobile phase of 0.1% formic acid in water or acetonitrile for separation and quantification. The assay has a lower limit of detection (LLOQ) of 10ng/mL and is shown to be linear up to 3000ng/mL. The intra- and inter-day precision of the assay expressed as a coefficient of variation (CV%) ranged from 4.01 to 8.81%. Furthermore, the suitability of this assay for measuring doxorubicin associated with DNA in vivo was demonstrated by using it to quantify the doxorubicin concentration within tumor samples from SKOV3 and HEC1A mice obtained 72h after administration of PEGylated liposomal doxorubicin (Doxil(®); PLD) at 6mg/kg IV x 1. This HPLC assay allows for sensitive intracellular quantification of doxorubicin and will be an important tool for future studies evaluating intracellular pharmacokinetics of doxorubicin and various nanoparticle formulations of doxorubicin. Copyright © 2015 Elsevier B.V. All rights reserved.

  17. [Comparison of the clinical performance of the ECLusys HBsAg II assay with the Lumipulse f and HISCL 2000-i HBsAg screening assays].

    Science.gov (United States)

    Sugiura, Aya; Iwahara, Kunihiro; Suga, Yasuyuki; Uchiyama, Sachinori; Maekawa, Masato

    2012-02-01

    We compared the ECLusys HBsAgII (ECL HBsAg) assay to the Lumipulse Forte (LPf HBsAg) and HISCL (HIS HBsAg) assays. Measurement of dilution panels for which the WHO HBsAg international reference panel was the parent specimen revealed that the ECL and HIS assays enabled detection to a theoretical level of 0.04 IU/mL, whereas the LPf assay enabled detection to a level of 0.08 IU/mL. In a specificity test using high RF positive specimens (n = 33), pregnancy specimens (n = 35), cytomegalovirus antibody positive specimens (n = 36), and high M protein positive specimens (n = 21) that were confirmed negative for HBsAg by the LPf assay, negative results were obtained for all specimens on the HIS assay, but the ECL assay yielded a positive result for one of the high RF positive specimens. This individual was suggested on further testing to be an HBV carrier who was strongly positive for HBc antibody. In HBsAg mutants detection test, the detection rate was 92.3% with the ECL assay and 69.2% with the HIS assay. In a correlation test using routinely collected clinical specimens (n = 155), including positive stock specimens, aside from the one case where the LPf assay gave a negative result but both the ECL and HIS assays gave positive results, all of the results were consistent for all specimens. The above results confirmed that the ECL assay is both highly sensitive and specific, and also enables a high rate of HBsAg mutant detection.

  18. Analytical Performance Characteristics of the Cepheid GeneXpert Ebola Assay for the Detection of Ebola Virus

    Science.gov (United States)

    Pinsky, Benjamin A.; Sahoo, Malaya K.; Sandlund, Johanna; Kleman, Marika; Kulkarni, Medha; Grufman, Per; Nygren, Malin; Kwiatkowski, Robert; Baron, Ellen Jo; Tenover, Fred; Denison, Blake; Higuchi, Russell; Van Atta, Reuel; Beer, Neil Reginald; Carrillo, Alda Celena; Naraghi-Arani, Pejman; Mire, Chad E.; Ranadheera, Charlene; Grolla, Allen; Lagerqvist, Nina; Persing, David H.

    2015-01-01

    Background The recently developed Xpert® Ebola Assay is a novel nucleic acid amplification test for simplified detection of Ebola virus (EBOV) in whole blood and buccal swab samples. The assay targets sequences in two EBOV genes, lowering the risk for new variants to escape detection in the test. The objective of this report is to present analytical characteristics of the Xpert® Ebola Assay on whole blood samples. Methods and Findings This study evaluated the assay’s analytical sensitivity, analytical specificity, inclusivity and exclusivity performance in whole blood specimens. EBOV RNA, inactivated EBOV, and infectious EBOV were used as targets. The dynamic range of the assay, the inactivation of virus, and specimen stability were also evaluated. The lower limit of detection (LoD) for the assay using inactivated virus was estimated to be 73 copies/mL (95% CI: 51–97 copies/mL). The LoD for infectious virus was estimated to be 1 plaque-forming unit/mL, and for RNA to be 232 copies/mL (95% CI 163–302 copies/mL). The assay correctly identified five different Ebola viruses, Yambuku-Mayinga, Makona-C07, Yambuku-Ecran, Gabon-Ilembe, and Kikwit-956210, and correctly excluded all non-EBOV isolates tested. The conditions used by Xpert® Ebola for inactivation of infectious virus reduced EBOV titer by ≥6 logs. Conclusion In summary, we found the Xpert® Ebola Assay to have high analytical sensitivity and specificity for the detection of EBOV in whole blood. It offers ease of use, fast turnaround time, and remote monitoring. The test has an efficient viral inactivation protocol, fulfills inclusivity and exclusivity criteria, and has specimen stability characteristics consistent with the need for decentralized testing. The simplicity of the assay should enable testing in a wide variety of laboratory settings, including remote laboratories that are not capable of performing highly complex nucleic acid amplification tests, and during outbreaks where time to detection

  19. High performance liquid chromatographic assay for the quantitation of total glutathione in plasma

    Science.gov (United States)

    Abukhalaf, Imad K.; Silvestrov, Natalia A.; Menter, Julian M.; von Deutsch, Daniel A.; Bayorh, Mohamed A.; Socci, Robin R.; Ganafa, Agaba A.

    2002-01-01

    A simple and widely used homocysteine HPLC procedure was applied for the HPLC identification and quantitation of glutathione in plasma. The method, which utilizes SBDF as a derivatizing agent utilizes only 50 microl of sample volume. Linear quantitative response curve was generated for glutathione over a concentration range of 0.3125-62.50 micromol/l. Linear regression analysis of the standard curve exhibited correlation coefficient of 0.999. Limit of detection (LOD) and limit of quantitation (LOQ) values were 5.0 and 15 pmol, respectively. Glutathione recovery using this method was nearly complete (above 96%). Intra-assay and inter-assay precision studies reflected a high level of reliability and reproducibility of the method. The applicability of the method for the quantitation of glutathione was demonstrated successfully using human and rat plasma samples.

  20. Performance of scintillation proximity assay (SPA) to measure the level of VEGFR 1 protein

    International Nuclear Information System (INIS)

    LEE, So-Young; LIM, Jae-Cheong; KIM, Jin-Joo

    2014-01-01

    Scintillation proximity assay is a one of radioimmunoassay and can be assayed without the washing or filtration procedures normally used to separate bound from free fractions. Due to its simplicity and high-throughput protocol, it is broadly applicable to immunology, receptor binding, monitoring receptor-ligand interactions and enzyme reactions. Briefly, an antibody or receptor is coated on SPA beads. When a radiolabeled antigen or ligand binds to the beads, the SPA beads stimulate to emit short range electrons. The 3 H and 125 I are commonly used for radiolabeling and the produced photons are detectable with a liquid scintillation counter (LSC). A binding affinity of unlabeled ligands can be determined by competitive reaction of the radiolabeled ligands. Bevacizumab is a recombinant humanized monoclonal antibody, and can stop or delay growth of tumors by inhibiting vascular endothelial growth factor (VEGF). Bevacizumab was approved by FDA for metastatic cancer such as colorectal cancers, ovarian cancers, breast cancers and glioblastoma multiform of the brain. Recently, Dan G. duda et al. was reported that the concentration of vascular endothelial growth factor receptor-1 (VEGFR-1) in plasma may potentially be used as a negative selection biomarker. In this study, we describe a method using scintillation proximity assay to detect the amounts of VEGFR-1 protein. This method is successfully used to measure the concentration of VEGFR-1 protein in human cell extracts. In summary, a simple and sensitive assay is developed for measuring the amount of VEGFR 1 protein in cancer cell lysate using SPA beads. The antibody coating on the beads and antigen binding are achieved in one mixing step

  1. Performance of scintillation proximity assay (SPA) to measure the level of VEGFR 1 protein

    Energy Technology Data Exchange (ETDEWEB)

    LEE, So-Young; LIM, Jae-Cheong; KIM, Jin-Joo [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2014-10-15

    Scintillation proximity assay is a one of radioimmunoassay and can be assayed without the washing or filtration procedures normally used to separate bound from free fractions. Due to its simplicity and high-throughput protocol, it is broadly applicable to immunology, receptor binding, monitoring receptor-ligand interactions and enzyme reactions. Briefly, an antibody or receptor is coated on SPA beads. When a radiolabeled antigen or ligand binds to the beads, the SPA beads stimulate to emit short range electrons. The {sup 3}H and {sup 125}I are commonly used for radiolabeling and the produced photons are detectable with a liquid scintillation counter (LSC). A binding affinity of unlabeled ligands can be determined by competitive reaction of the radiolabeled ligands. Bevacizumab is a recombinant humanized monoclonal antibody, and can stop or delay growth of tumors by inhibiting vascular endothelial growth factor (VEGF). Bevacizumab was approved by FDA for metastatic cancer such as colorectal cancers, ovarian cancers, breast cancers and glioblastoma multiform of the brain. Recently, Dan G. duda et al. was reported that the concentration of vascular endothelial growth factor receptor-1 (VEGFR-1) in plasma may potentially be used as a negative selection biomarker. In this study, we describe a method using scintillation proximity assay to detect the amounts of VEGFR-1 protein. This method is successfully used to measure the concentration of VEGFR-1 protein in human cell extracts. In summary, a simple and sensitive assay is developed for measuring the amount of VEGFR 1 protein in cancer cell lysate using SPA beads. The antibody coating on the beads and antigen binding are achieved in one mixing step.

  2. On performance experience and measurements with Ningyo Waste Assay System (NWAS). 3

    International Nuclear Information System (INIS)

    Zaima, Naoki; Nakashima, Shin'ichi; Nakatsuka, Yoshiaki; Kado, Kazumi; Fujiki, Naoki

    2014-03-01

    A uranium mass assay system, NWAS (Ningyo Waste Assay System), for 200-litter wastes drums applied by NDA method was developed and accumulated the data of the actual uranium bearing wastes drums. The system consists of the 16 pieces of Helium-3 proportional counters for neutron detection generated from U-234(α,n) reaction or U-238 spontaneous fissions with polyethylene moderation and a Germanium solid state detector (Ge-SSD) for gamma ray detection as to determine uranium enrichment. In previous report, some measurement experiences had been introduced briefly. After that the measurements campaigns against the actual wastes drums stored in URCP had been carried out successfully, the uranium determination data of 850 drums had been accumulated approximately. Those characteristics were rich in variety including various kinds of matrices, uranium chemical compositions and range of uranium mass and so on. These works have contributed the decrease of the MUF in URCP, for which was the first purpose of introduction of NWAS. On the other hand several considerable problems on the system or methodology had been revealed technically or analytically through the measurements experiences. Such experiences are to be described precisely, in addition newly gained knowledge will be marshaled. Furthermore as the next improvement plans, the active neutrons assay for uranium bearing wastes drums are now progressing. The results of complications will lead us to the progressive next steps. (author)

  3. The influence of uncertainties of measurements in laboratory performance evaluation using an intercomparison program of radionuclide assays in environmental samples

    International Nuclear Information System (INIS)

    Tauhata, Luiz; Elizabeth Couto Machado Vianna, Maria; Eduardo de Oliveira, Antonio; Cristina de Melo Ferreira, Ana; Julia Camara da Silva Braganca, Maura; Faria Clain, Almir

    2006-01-01

    To show the influence of measurement uncertainties in performance evaluation of laboratories, data from 42 comparison runs were evaluated using two statistical criteria. The normalized standard deviation, D, used by US EPA, that mainly takes into account the accuracy, and the normalized deviation, E, that includes the individual laboratory uncertainty used for performance evaluation in the key-comparisons by BIPM. The results show that data evaluated by the different criteria give a significant deviation of laboratory performance in each radionuclide assay when we analyse a large quantity of data

  4. Evaluation of hemoglobin A1c measurement from filter paper using high-performance liquid chromatography and immunoturbidimetric assay.

    Science.gov (United States)

    Wu, Yonghua; Yang, Xu; Wang, Haining; Li, Zhenrong; Wang, Tiancheng

    2017-04-01

    Glycated hemoglobin (HbA 1c ) measurement from whole blood (WB) samples is inconvenient for epidemic surveillance and self-monitoring of glycemic level. We evaluated HbA 1c measurement from WB blotted on filter paper (FP), which can be easily transported to central laboratories, with high-performance liquid chromatography (HPLC) and immunoturbidimetric assay (ITA). WB was applied to Whatman filter paper. By using HPLC and WB samples as reference methods, these FP samples were evaluated on HPLC and ITA. Inter- and intra-assay variation, WB vs. FP agreement and sample stability at 20-25 °C and -70 °C were assessed by statistical analysis. Results showed that the coefficient of variation (CV, %) of FP samples for HPLC and ITA were 0.44-1.02% and 1.47-2.72%, respectively (intra-assay); 2.13-3.56% and 3.21-4.82%, respectively (inter-assay). The correlation of WB HPLC with FP analyzed using HPLC and ITA are both significant (p < 0.001). Sample stability showed that FP method up to 5 days at 20-25 °C and 5 weeks at -70 °C is accurate and reproducible. In conclusion, FP samples analyzed by HPLC and ITA can both provide an alternative to WB for HbA 1c measurement, supporting the use of FP method in epidemic surveillance and healthcare units.

  5. Analytical and clinical performance of the new Fujirebio 25-OH vitamin D assay, a comparison with liquid chromatography-tandem mass spectrometry (LC-MS/MS) and three other automated assays.

    Science.gov (United States)

    Saleh, Lanja; Mueller, Daniel; von Eckardstein, Arnold

    2016-04-01

    We evaluated the analytical and clinical performance of the new Lumipulse® G 25-OH vitamin D assay from Fujirebio, and compared it to a liquid chromatography-tandem mass spectrometry (LC-MS/MS) method and three other commercial automated assays. Total 25 hydroxy vitamin D (25(OH)D) levels were measured in 100 selected serum samples from our routine analysis with Fujirebio 25(OH)D assay. The results were compared with those obtained with LC-MS/MS and three other automated 25(OH)D assays (Abbott, Beckman, and Roche). The accuracy of each assay tested was evaluated against a Labquality reference serum panel for 25(OH)D (Ref!25OHD; University of Ghent). Intra- and inter-day imprecision of the Fujirebio 25(OH)D assay was Lumipulse G 25-OH vitamin D assay from Fujirebio demonstrated a good correlation with LC-MS/MS and some immunoassays. The performance of the assay is well-suited for routine 25(OH)D measurement in clinical serum samples. A correction for the observed negative bias vs. LC-MS/MS could be considered.

  6. An easy-to-perform photometric assay for methyltransferase activity measurements.

    Science.gov (United States)

    Schäberle, Till F; Siba, Christian; Höver, Thomas; König, Gabriele M

    2013-01-01

    Methyltransferases (MTs) catalyze the transfer of a methyl group from S-adenosylmethionine (SAM) to a suitable substrate. Such methylations are important modifications in secondary metabolisms, especially on natural products produced by polyketide synthases and nonribosomal peptide synthetases, many of which are of special interest due to their prominent pharmacological activities (e.g., lovastatin, cyclosporin). To gain basic biochemical knowledge on the methylation process, it is of immense relevance to simplify methods concerning experimental problems caused by a large variety in substrates. Here, we present a photometric method to analyze MT activity by measuring SAM consumption in a coupled enzyme assay. Copyright © 2012 Elsevier Inc. All rights reserved.

  7. Performance of PCR-reverse blot hybridization assay for detection of rifampicin-resistant Mycobacterium leprae.

    Science.gov (United States)

    Wang, Hye-young; Kim, Hyunjung; Kim, Yeun; Bang, Hyeeun; Kim, Jong-Pill; Hwang, Joo Hwan; Cho, Sang-Nae; Kim, Tae Ue; Lee, Hyeyoung

    2015-10-01

    Drug resistance in Mycobacterium leprae is a significant problem in countries where leprosy is endemic. A sensitive, specific, and high-throughput reverse blot hybridization assay (REBA) for the detection of genotypic resistance to rifampicin (RIF) was designed and evaluated. It has been shown that resistance to RIF in M. leprae involves mutations in the rpoB gene encoding the -subunit of the RNA polymerase. The PCR-REBA simultaneously detects both 6 wild-type regions and 5 different mutations (507 AGC, 513 GTG, 516 TAT, 531 ATG, and 531 TTC) including the most prevalent mutations at positions 507 and 531. Thirty-one clinical isolates provided by Korea Institute of Hansen-s Disease were analyzed by PCR-REBA with RIF resistance of rpoB gene. As a result, missense mutations at codons 507 AGC and 531 ATG with 2-nucleotide substitutions were found in one sample, and a missense mutation at codon 516 TAT and ΔWT6 (deletion of 530-534) was found in another sample. These cases were confirmed by DNA sequence analysis. This rapid, simple, and highly sensitive assay provides a practical alternative to sequencing for genotypic evaluation of RIF resistance in M. leprae.

  8. Analytical and clinical performance of the CDC real time RT-PCR assay for detection and typing of dengue virus.

    Directory of Open Access Journals (Sweden)

    Gilberto A Santiago

    Full Text Available Dengue is an acute illness caused by the positive-strand RNA dengue virus (DENV. There are four genetically distinct DENVs (DENV-1-4 that cause disease in tropical and subtropical countries. Most patients are viremic when they present with symptoms; therefore, RT-PCR has been increasingly used in dengue diagnosis. The CDC DENV-1-4 RT-PCR Assay has been developed as an in-vitro diagnostic platform and was recently approved by the US Food and Drug Administration (FDA for detection of dengue in patients with signs or symptoms of mild or severe dengue. The primers and probes of this test have been designed to detect currently circulating strains of DENV-1-4 from around the world at comparable sensitivity. In a retrospective study with 102 dengue cases confirmed by IgM anti-DENV seroconversion in the convalescent sample, the RT-PCR Assay detected DENV RNA in 98.04% of the paired acute samples. Using sequencing as a positive indicator, the RT-PCR Assay had a 97.92% positive agreement in 86 suspected dengue patients with a single acute serum sample. After extensive validations, the RT-PCR Assay performance was highly reproducible when evaluated across three independent testing sites, did not produce false positive results for etiologic agents of other febrile illnesses, and was not affected by pathological levels of potentially interfering biomolecules. These results indicate that the CDC DENV-1-4 RT-PCR Assay provides a reliable diagnostic platform capable for confirming dengue in suspected cases.

  9. Analytical and clinical performance of the CDC real time RT-PCR assay for detection and typing of dengue virus.

    Science.gov (United States)

    Santiago, Gilberto A; Vergne, Edgardo; Quiles, Yashira; Cosme, Joan; Vazquez, Jesus; Medina, Juan F; Medina, Freddy; Colón, Candimar; Margolis, Harold; Muñoz-Jordán, Jorge L

    2013-01-01

    Dengue is an acute illness caused by the positive-strand RNA dengue virus (DENV). There are four genetically distinct DENVs (DENV-1-4) that cause disease in tropical and subtropical countries. Most patients are viremic when they present with symptoms; therefore, RT-PCR has been increasingly used in dengue diagnosis. The CDC DENV-1-4 RT-PCR Assay has been developed as an in-vitro diagnostic platform and was recently approved by the US Food and Drug Administration (FDA) for detection of dengue in patients with signs or symptoms of mild or severe dengue. The primers and probes of this test have been designed to detect currently circulating strains of DENV-1-4 from around the world at comparable sensitivity. In a retrospective study with 102 dengue cases confirmed by IgM anti-DENV seroconversion in the convalescent sample, the RT-PCR Assay detected DENV RNA in 98.04% of the paired acute samples. Using sequencing as a positive indicator, the RT-PCR Assay had a 97.92% positive agreement in 86 suspected dengue patients with a single acute serum sample. After extensive validations, the RT-PCR Assay performance was highly reproducible when evaluated across three independent testing sites, did not produce false positive results for etiologic agents of other febrile illnesses, and was not affected by pathological levels of potentially interfering biomolecules. These results indicate that the CDC DENV-1-4 RT-PCR Assay provides a reliable diagnostic platform capable for confirming dengue in suspected cases.

  10. Performance of the new automated Abbott RealTime MTB assay for rapid detection of Mycobacterium tuberculosis complex in respiratory specimens.

    Science.gov (United States)

    Chen, J H K; She, K K K; Kwong, T-C; Wong, O-Y; Siu, G K H; Leung, C-C; Chang, K-C; Tam, C-M; Ho, P-L; Cheng, V C C; Yuen, K-Y; Yam, W-C

    2015-09-01

    The automated high-throughput Abbott RealTime MTB real-time PCR assay has been recently launched for Mycobacterium tuberculosis complex (MTBC) clinical diagnosis. This study would like to evaluate its performance. We first compared its diagnostic performance with the Roche Cobas TaqMan MTB assay on 214 clinical respiratory specimens. Prospective analysis of a total 520 specimens was then performed to further evaluate the Abbott assay. The Abbott assay showed a lower limit of detection at 22.5 AFB/ml, which was more sensitive than the Cobas assay (167.5 AFB/ml). The two assays demonstrated a significant difference in diagnostic performance (McNemar's test; P = 0.0034), in which the Abbott assay presented significantly higher area under curve (AUC) than the Cobas assay (1.000 vs 0.880; P = 0.0002). The Abbott assay demonstrated extremely low PCR inhibition on clinical respiratory specimens. The automated Abbott assay required only very short manual handling time (0.5 h), which could help to improve the laboratory management. In the prospective analysis, the overall estimates for sensitivity and specificity of the Abbott assay were both 100 % among smear-positive specimens, whereas the smear-negative specimens were 96.7 and 96.1 %, respectively. No cross-reactivity with non-tuberculosis mycobacterial species was observed. The superiority in sensitivity of the Abbott assay for detecting MTBC in smear-negative specimens could further minimize the risk in MTBC false-negative detection. The new Abbott RealTime MTB assay has good diagnostic performance which can be a useful diagnostic tool for rapid MTBC detection in clinical laboratories.

  11. PERFORMANCE EVALUATION OF A PROTOTYPE ARCHITECT ANTIBODY ASSAY FOR BABESIA MICROTI.

    Science.gov (United States)

    Cheng, Kevin; Coller, Kelly E; Marohnic, Christopher C; Pfeiffer, Zachary A; Fino, James R; Elsing, Randee R; Bergsma, Janet; Marcinkus, Marilee A; Kar, Alak K; Gumbs, Orlando H; Otis, Kathy S; Fishpaugh, Jeffrey; Schultz, Phillip W; Pope, Mark R; Narvaez, Alfredo R; Wong, Susan J; Madison-Antenucci, Susan; Leary, Thomas P; Dawson, George J

    2018-05-09

    The tick-borne protozoan Babesia microti is responsible for more than 200 cases of transfusion-transmitted babesiosis (TTB) infection in the United States over the last 30 years. Measures to mitigate the risk of TTB include nucleic acid testing (NAT) and B. microti antibody testing. A fully automated prototype B. microti antibody test was developed on the ARCHITECT instrument. The specificity was determined to be 99.98% in volunteer blood donors (n=28,740) from areas considered as low endemic for B. microti The sensitivity of the prototype test was studied in experimentally-infected macaques; a total of 128 samples were detected compared to 125 with the indirect fluorescent antibody test (IFA), additionally, 83 (89.2%) of the PCR positive samples were detected compared to 81 (87.1%) using the IFA test. All PCR positive samples that tested negative in the prototype antibody test were pre-seroconversion period samples. Following seroconversion, periods of intermittent parasitemia occurred; 17 PCR negative samples drawn in-between PCR positive bleed dates, tested positive both by the prototype test (robust reactivity) and IFA (marginal reactivity) prior to the administration of therapeutic drugs, indicating that the PCR test failed to detect samples from persistently infected macaques. The prototype assay detected 56 of 58 (96.6%) human subjects diagnosed with clinical babesiosis by both PCR and IFA testing. Overall, the prototype anti-babesia assay provides a highly sensitive and specific test for the diagnosis of B. microti infection. While PCR is preferred for detection of window period parasitemia, antibody tests detect infected subjects during periods of low level parasitemia. Copyright © 2018 Cheng et al.

  12. Performance of a real-time PCR assay in routine bovine mastitis diagnostics compared with in-depth conventional culture.

    Science.gov (United States)

    Hiitiö, Heidi; Riva, Rauna; Autio, Tiina; Pohjanvirta, Tarja; Holopainen, Jani; Pyörälä, Satu; Pelkonen, Sinikka

    2015-05-01

    Reliable identification of the aetiological agent is crucial in mastitis diagnostics. Real-time PCR is a fast, automated tool for detecting the most common udder pathogens directly from milk. In this study aseptically taken quarter milk samples were analysed with a real-time PCR assay (Thermo Scientific PathoProof Mastitis Complete-12 Kit, Thermo Fisher Scientific Ltd.) and by semi-quantitative, in-depth bacteriological culture (BC). The aim of the study was to evaluate the diagnostic performance of the real-time PCR assay in routine use. A total of 294 quarter milk samples from routine mastitis cases were cultured in the national reference laboratory of Finland and examined with real-time PCR. With BC, 251 out of 294 (85.7%) of the milk samples had at least one colony on the plate and 38 samples were considered contaminated. In the PCR mastitis assay, DNA of target species was amplified in 244 samples out of 294 (83.0%). The most common bacterial species detected in the samples, irrespective of the diagnostic method, was the coagulase negative staphylococci (CNS) group (later referred as Staphylococcus spp.) followed by Staphylococcus aureus. Sensitivity (Se) and specificity (Sp) for the PCR assay to provide a positive Staph. aureus result was 97.0 and 95.8% compared with BC. For Staphylococcus spp., the corresponding figures were 86.7 and 75.4%. Our results imply that PCR performed well as a diagnostic tool to detect Staph. aureus but may be too nonspecific for Staphylococcus spp. in routine use with the current cut-off Ct value (37.0). Using PCR as the only microbiological method for mastitis diagnostics, clinical relevance of the results should be carefully considered before further decisions, for instance antimicrobial treatment, especially when minor pathogens with low amount of DNA have been detected. Introducing the concept of contaminated samples should also be considered.

  13. Analytical and clinical performance of the new Fujirebio 25-OH vitamin D assay, a comparison with liquid chromatography-tandem mass spectrometry (LC-MS/MS) and three other automated assays

    OpenAIRE

    Saleh, Lanja; Mueller, Daniel; von Eckardstein, Arnold

    2015-01-01

    BACKGROUND: We evaluated the analytical and clinical performance of the new Lumipulse® G 25-OH vitamin D assay from Fujirebio, and compared it to a liquid chromatography-tandem mass spectrometry (LC-MS/MS) method and three other commercial automated assays. METHODS: Total 25 hydroxy vitamin D (25(OH)D) levels were measured in 100 selected serum samples from our routine analysis with Fujirebio 25(OH)D assay. The results were compared with those obtained with LC-MS/MS and three other automat...

  14. New and highly sensitive assay for L-5-hydroxytryptophan decarboxylase activity by high-performance liquid chromatography-voltammetry.

    Science.gov (United States)

    Rahman, M K; Nagatsu, T; Kato, T

    1980-12-12

    This paper describes a new, inexpensive and highly sensitive assay for aromatic L-amino acid decarboxylase (AADC) activity, using L-5-hydroxytryptophan (L-5-HTP) as substrate, in rat and human brains and serum by high-performance liquid chromatography (HPLC) with voltammetric detection. L-5-HTP was used as substrate and D-5-HTP for the blank. After isolating serotonin (5-HT) formed enzymatically from L-5-HTP on a small Amberlite CG-50 column, the 5-HT was eluted with hydrochloric acid and assayed by HPLC with a voltammetric detector. N-Methyldopamine was added to each incubation mixture as an internal standard. This method is sensitive enough to measure 5-HT, formed by the enzyme, 100 fmol to 140 pmol or more. An advantage of this method is that one can incubate the enzyme for longer time (up to 150 min), as compared with AADC assay using L-DOPA as substrate, resulting in a very high sensitivity. By using this new method, AADC activity was discovered in rat serum.

  15. Performance Characteristics of Different Anti-Double-Stranded DNA Antibody Assays in the Monitoring of Systemic Lupus Erythematosus

    Directory of Open Access Journals (Sweden)

    Michael Mahler

    2017-01-01

    Full Text Available Objective. We sought to evaluate different anti-double-stranded DNA assays for their performance characteristics in monitoring disease activity fluctuations in systemic lupus erythematosus (SLE. Methods. 36 active SLE patients were followed monthly. At each study visit (total n=371, blood was collected and disease activity was scored using the SELENA-SLEDAI (excluding anti-dsDNA or complement components and by a physician’s global assessment (PGA. Four anti-dsDNA tests were compared. Linear mixed-effects models with random intercept and fixed slopes were used to evaluate the relationship between the longitudinal fluctuations of disease activity and anti-dsDNA titers. Results. At enrollment, positivity for QUANTA Lite and high-avidity anti-dsDNA assay was both 64% and significantly lower than anti-dsDNA positivity by QUANTA Flash (83% and CLIFT (96%. Linear mixed-effects modeling indicated that the change in clinical SELENA-SLEDAI scores was associated with the titers of all anti-dsDNA with QUANTA Flash yielding the highest marginal R2 (0.15; p<0.01. QUANTA Flash was the only anti-dsDNA assay significantly associated with the change in PGA (marginal R2=0.05; p<0.01. Conclusion. These data indicate that anti-dsDNA antibodies determined by QUANTA Flash have a value in monitoring SLE disease activity.

  16. Analytical and diagnostic performance of a qPCR assay for Ichthyophonus spp. compared to the tissue culture 'gold standard'.

    Science.gov (United States)

    Lowe, Vanessa C; Hershberger, Paul K; Friedman, Carolyn S

    2018-06-04

    Parasites of the genus Ichthyophonus infect many fish species and have a non-uniform distribution within host tissues. Due in part to this uneven distribution, the comparative sensitivity and accuracy of using molecular-based detection methods versus culture to estimate parasite prevalence is under debate. We evaluated the analytical and diagnostic performance of an existing qPCR assay in comparison to the 'gold standard' culture method using Pacific herring Clupea pallasii with known exposure history. We determined that the assay is suitable for use in this host, and diagnostic specificity was consistently high (>98%) in both heart and liver tissues. Diagnostic sensitivity could not be fully assessed due to low infection rates, but our results suggest that qPCR is not as sensitive as culture under all circumstances. Diagnostic sensitivity of qPCR relative to culture is likely affected by the amount of sample processed. The prevalence values estimated by the 2 methods were not significantly different when sample amounts were equal (heart tissue), but when the assayed sample amounts were unequal (liver tissue), the culture method detected a significantly higher prevalence of the parasite than qPCR. Further, culture of liver also detected significantly more Ichthyophonus infections than culture of heart, suggesting that the density and distribution of parasites in tissues also plays a role in assay sensitivity. This sensitivity issue would be most problematic for fish with light infections. Although qPCR does not detect the presence of a live organism, DNA-based pathogen detection methods provide the opportunity for alternate testing strategies when culture is not possible.

  17. Area-under-the-curve monitoring of cyclosporine therapy: Performance of different assay methods and their target concentrations

    International Nuclear Information System (INIS)

    Grevel, J.; Napoli, K.L.; Gibbons, S.; Kahan, B.D.

    1990-01-01

    The measurement of areas under the concentration-time curve (AUC) was recently introduced as an alternative to trough level monitoring of cyclosporine therapy. The AUC is divided by the oral dosing interval to calculate an average concentration. All measurements are performed at clinical steady state. The initial evaluation of AUC monitoring showed advantages over trough level monitoring with concentrations of cyclosporine measured in serum by the polyclonal radioimmunoassay of Sandoz. This assay technique is no longer available and the following assays were performed in parallel during up to 173 AUC determinations in 51 consecutive renal transplant patients: polyclonal fluorescence polarization immunoassay of Abbott in serum, specific and nonspecific monoclonal radioimmunoassays using 3 H and 125 I tracers in serum and whole blood, and high performance liquid chromatography in whole blood. Both trough levels and average concentrations at steady state measured by those different techniques were significantly correlated with the oral dose. The best correlation (r2 = 0.54) was shown by average concentrations measured in whole blood by the specific monoclonal radioimmunoassay of Sandoz ( 3 H tracer). This monitoring technique was also associated with the smallest absolute error between repeated observations in the same patient while the oral dose rate remained the same or was changed. Both allegedly specific monoclonal radioimmunoassays (with 3 H and 125 I tracer) measured significantly higher concentrations than the liquid chromatography

  18. Clinical and analytical performance of the BD Onclarity™ HPV assay for detection of CIN2+ lesions on SurePath samples

    DEFF Research Database (Denmark)

    Ejegod, Ditte Møller; Junge, Jette; Franzmann, Maria

    2016-01-01

    BACKGROUND: The novel BD Onclarity(TM) HPV assay (Onclarity) on the BD Viper™ LT system (BD Diagnostics, Sparks, MD), detects E6/E7 DNA from 13 high-risk HPV genotypes and HPV66. We compared the analytical and clinical performance of the Onclarity Assay to that of Hybrid Capture 2 and LINEAR ARRAY...

  19. Performance of the Epstein-Barr Virus and Herpes Simplex Virus Immunoglobulin M Assays on the Liaison Platform with Sera from Patients Displaying Acute Parvovirus B19 Infection▿

    Science.gov (United States)

    Costa, Elisa; Tormo, Nuria; Clari, María Ángeles; Bravo, Dayana; Muñoz-Cobo, Beatriz; Navarro, David

    2009-01-01

    Acute parvovirus B19 infection has been reported to cause false-positive results frequently in the Epstein-Barr (EBV) and herpes simplex virus (HSV) immunoglobulin M (IgM) assays from DiaSorin performed on the Liaison platform. We tested 65 sera from patients with a presumptive or conclusive diagnosis of acute parvovirus B19 infection in both assays and obtained no false-positive results in the EBV IgM test and 10.4% nonspecific reactivities in the HSV IgM assay. Our data support the specificity of both assays in this clinical setting. PMID:19571110

  20. High performance liquid chromatographic-mass spectrometric assay for the quantitation of BMS-204352 in dog K(3)EDTA plasma.

    Science.gov (United States)

    Yao, Ming; Mantha, Subbarao; Shah, Vinod R; Vachharajani, Nimish N; Arnold, Mark E; Pursley, Janice M; Srinivas, Nuggehally R

    2002-05-01

    A high performance liquid chromatographic-mass spectrometric (LC/MS) assay was developed and validated for the determination of BMS-204352 in dog K(3)EDTA plasma. A 0.5 mL aliquot of control plasma was spiked with BMS-204352 and internal standard (IS) and buffered with 1 mL of 5 mM ammonium acetate. The mixture was then extracted with 3 mL of toluene. After separation and evaporation of the organic phase to dryness using nitrogen at 40 degrees C, the residue was reconstituted in the mobile phase and 25 microL of the sample were injected onto a Hypersil C(18) column (2 x 50 mm; 3 microm) at a flow rate of 0.5 mL/min. The mobile phase was consisted of two solvent mixtures (A and B). Solvent A was composed of 5 mM ammonium acetate and 0.1% triethylamine in 75:25 v/v water:methanol, pH adjusted to 5.5 with glacial acetic acid, and solvent B was 5 mM ammonium acetate in methanol. A linear gradient system was used to elute the analytes. The mass spectrometer was programmed to admit the de-protonated molecules at m/z 352.7 (IS) and m/z 357.9 (BMS-204352). Standard curves of BMS-204352 were linear (r(2) > or = 0.998) over the concentration range of 0.5-1000 ng/mL. The mean predicted quality control (QC) concentrations deviated less than 5.1% from the corresponding nominal values (ie 4, 80, 400 and 2000 ng/mL); the within- and between-assay precision of the assay were within 5.5% relative standard deviation. Stability of BMS-204352 was confirmed after at least three freeze/thaw cycles and BMS-204532 was stable in dog plasma when stored frozen at or below -20 degrees C for at least 16 weeks in spiked QC samples and for at least 4 1/2 weeks for in vivo study samples. BMS-204352 and IS were stable in the injection solvent at room temperature for at least 24 h. The assay was applied to delineate the pharmacokinetic disposition of BMS-204352 in dogs following a single intravenous dose administration. In conclusion, the assay is accurate, precise, specific, sensitive and

  1. An on-line high performance liquid chromatography-crocin bleaching assay for detection of antioxidants

    NARCIS (Netherlands)

    Bountagkidou, O.; Klift, van der E.J.C.; Tsimidou, M.Z.; Ordoudi, S.A.; Beek, van T.A.

    2012-01-01

    An on-line HPLC (high performance liquid chromatography) method for the rapid screening of individual antioxidants in mixtures was developed using crocin as a substrate (i.e. oxidation probe) and 2,2'-azobis(2-amidinopropane dihydrochloride (AAPH)) in phosphate buffer (pH 7.5) as a radical

  2. Performance standard-based validation study for local lymph node assay: 5-bromo-2-deoxyuridine-flow cytometry method.

    Science.gov (United States)

    Ahn, Ilyoung; Kim, Tae-Sung; Jung, Eun-Sun; Yi, Jung-Sun; Jang, Won-Hee; Jung, Kyoung-Mi; Park, Miyoung; Jung, Mi-Sook; Jeon, Eun-Young; Yeo, Kyeong-Uk; Jo, Ji-Hoon; Park, Jung-Eun; Kim, Chang-Yul; Park, Yeong-Chul; Seong, Won-Keun; Lee, Ai-Young; Chun, Young Jin; Jeong, Tae Cheon; Jeung, Eui Bae; Lim, Kyung-Min; Bae, SeungJin; Sohn, Soojung; Heo, Yong

    2016-10-01

    Local lymph node assay: 5-bromo-2-deoxyuridine-flow cytometry method (LLNA: BrdU-FCM) is a modified non-radioisotopic technique with the additional advantages of accommodating multiple endpoints with the introduction of FCM, and refinement and reduction of animal use by using a sophisticated prescreening scheme. Reliability and accuracy of the LLNA: BrdU-FCM was determined according to OECD Test Guideline (TG) No. 429 (Skin Sensitization: Local Lymph Node Assay) performance standards (PS), with the participation of four laboratories. Transferability was demonstrated through successfully producing stimulation index (SI) values for 25% hexyl cinnamic aldehyde (HCA) consistently greater than 3, a predetermined threshold, by all participating laboratories. Within- and between-laboratory reproducibility was shown using HCA and 2,4-dinitrochlorobenzene, in which EC2.7 values (the estimated concentrations eliciting an SI of 2.7, the threshold for LLNA: BrdU-FCM) fell consistently within the acceptance ranges, 0.025-0.1% and 5-20%, respectively. Predictive capacity was tested using the final protocol version 1.3 for the 18 reference chemicals listed in OECD TG 429, of which results showed 84.6% sensitivity, 100% specificity, and 88.9% accuracy compared with the original LLNA. The data presented are considered to meet the performance criteria for the PS, and its predictive capacity was also sufficiently validated. Copyright © 2016 Elsevier Inc. All rights reserved.

  3. The performance of the SEPT9 gene methylation assay and a comparison with other CRC screening tests: A meta-analysis.

    Science.gov (United States)

    Song, Lele; Jia, Jia; Peng, Xiumei; Xiao, Wenhua; Li, Yuemin

    2017-06-08

    The SEPT9 gene methylation assay is the first FDA-approved blood assay for colorectal cancer (CRC) screening. Fecal immunochemical test (FIT), FIT-DNA test and CEA assay are also in vitro diagnostic (IVD) tests used in CRC screening. This meta-analysis aims to review the SEPT9 assay performance and compare it with other IVD CRC screening tests. By searching the Ovid MEDLINE, EMBASE, CBMdisc and CJFD database, 25 out of 180 studies were identified to report the SEPT9 assay performance. 2613 CRC cases and 6030 controls were included, and sensitivity and specificity were used to evaluate its performance at various algorithms. 1/3 algorithm exhibited the best sensitivity while 2/3 and 1/1 algorithm exhibited the best balance between sensitivity and specificity. The performance of the blood SEPT9 assay is superior to that of the serum protein markers and the FIT test in symptomatic population, while appeared to be less potent than FIT and FIT-DNA tests in asymptomatic population. In conclusion, 1/3 algorithm is recommended for CRC screening, and 2/3 or 1/1 algorithms are suitable for early detection for diagnostic purpose. The SEPT9 assay exhibited better performance in symptomatic population than in asymptomatic population.

  4. Calibration of UFBC counters and their performance in the assay of large mass plutonium samples

    International Nuclear Information System (INIS)

    Verrecchia, G.P.D.; Smith, B.G.R.; Cranston, R.

    1991-01-01

    This paper reports on the cross-calibration of four Universal Fast Breeder reactor assembly coincidence (UFBC) counters using multi-can containers of Plutonium oxide powders with masses between 2 and 12 Kg of plutonium and a parametric study on the sensitivity of the detector response to the positioning or removal and substitution of the material with empty cans. The paper also reports on the performance of the UFBC for routine measurements on large mass, multi-can containers of plutonium oxide powders and compares the results to experience previously obtained in the measurement of fast reactor type fuel assemblies in the mass range 2 to 16 Kg of plutonium

  5. Non-Tuberculous Mycobacteria and the Performance of Interferon Gamma Release Assays in Denmark

    DEFF Research Database (Denmark)

    Hermansen, Thomas Stig; Thomsen, Vibeke Østergaard; Lillebaek, Troels

    2014-01-01

    , nationwide patient data on positive NTM cultures (n = 925) were combined with nationwide data on QFT results (n = 16,133), both retrieved from the International Reference Laboratory of Mycobacteriology, Denmark. A total of 112 patients with NTM infections had a QFT performed, 53 patients had definite NTM...... disease, 10 had possible disease and 49 had NTM colonization. RESULTS: QFT was positive in 8% (4/53) of patients with definite disease, 40% (4/10) with possible disease and 31% (15/49) with colonization. Positivity rate was lowest among patients with definite disease infected with NTM without the RD1...

  6. (MTT) dye reduction assay.

    African Journals Online (AJOL)

    to inhibit proliferation of HeLa cells was determined using the 3443- dimethylthiazol-2-yl)-2,5-diphenyl-tetrazolium bromide (MTT) dye reduction assay. Extracts from roots of Agathisanthemum bojeri, Synaptolepis kirkii and Zanha africana and the leaf extract of Physalis peruviana at a concentration of 10 pg/ml inhibited cell ...

  7. Self-motivated and stress-response performance assays in mice are age-dependent.

    Science.gov (United States)

    Ge, Xuan; Ciol, Marcia A; Pettan-Brewer, Christina; Goh, Jorming; Rabinovitch, Peter; Ladiges, Warren

    2017-05-01

    Chronic health conditions of the elderly lead to limitations in physical activity with disability, anxiety, and increased need for medical care and assisted living conditions. Physical performance tests are used to screen for pending loss of mobility and can serve as endpoints to monitor the effectiveness of intervention measures. Since limited mobility is associated with the physical and mental health of a person, evaluation of this in preclinical aging studies in mice will provide a translational approach for testing new intervention strategies. We assessed physiological parameters in 4, 12, 20 and 28month old C57BL/6 and CB6F1 male mice using a rotating rod, a free running wheel, and a photo beam activity field, designed to determine changes in coordinated walking ability, self-motivated running distance, and anxiety response to a novel environment, respectively. Older mice showed decreased coordinated walking times and decreased running distances, predictive of physical performance ability and motivation in the elderly. Changes in both lateral and vertical movements were observed in a novel cage environment suggesting different levels of anxiety. Because the genetic background of the two mouse strains influenced test results in an age-dependent manner, it is imperative to recognize that diverse genetic backgrounds in mice may yield different data in preclinical studies and would need to be interpreted individually for translational applications. Copyright © 2017 Elsevier Inc. All rights reserved.

  8. Use of proficiency samples to assess diagnostic laboratories in France performing a Trichinella digestion assay.

    Science.gov (United States)

    Vallée, Isabelle; Macé, Pauline; Forbes, Lorry; Scandrett, Brad; Durand, Benoit; Gajadhar, Alvin; Boireau, Pascal

    2007-07-01

    Routine diagnosis of animal trichinellosis for food safety and trade relies on a method of artificial digestion to free Trichinella muscle larvae from meat for subsequent identification by microscopy. As part of a quality control system, the French National Reference Laboratory (NRL) initiated ring trials to determine the sensitivity of the test performed in the 72 routine diagnostic laboratories in France. A method was devised to obtain calibrated meat samples containing known numbers of capsules with Trichinella spiralis muscle larvae. This method was based on an incomplete artificial digestion of Trichinella-infected mice carcasses to allow the collection of intact Trichinella capsules. Capsules were placed into a meatball of 100 +/- 2 g of pork and horsemeat to produce proficiency samples. Three categories of samples were prepared: small (3 to 5 capsules), medium (7 to 10), and large (12 to 15). The sensitivity was expressed as the percentage of muscle larvae recovered from each proficiency sample. Reproducibility was tested with ring trials organized between two NRLs (France and Canada), and a reference sensitivity of 84.9% was established. National ring trials were then organized in France, with the 72 routine diagnostic laboratories each receiving four proficiency samples per session. After five sessions, an improvement in the digest test sensitivity was observed. Results at the fifth session indicated sensitivities of 78.60% +/- 23.70%, 81.19% +/- 19.59%, and 80.52% +/- 14.71% muscle larvae for small, medium, and large samples, respectively. This study supports the use of proficiency samples to accurately evaluate the performance of routine diagnostic laboratories that conduct digestion tests for animal trichinellosis diagnosis.

  9. Assessment of a robust model protocol with accelerated throughput for a human recombinant full length estrogen receptor-alpha binding assay: protocol optimization and intralaboratory assay performance as initial steps towards validation.

    Science.gov (United States)

    Freyberger, Alexius; Wilson, Vickie; Weimer, Marc; Tan, Shirlee; Tran, Hoai-Son; Ahr, Hans-Jürgen

    2010-08-01

    Despite about two decades of research in the field of endocrine active compounds, still no validated human recombinant (hr) estrogen receptor-alpha (ERalpha) binding assay is available, although hr-ERalpha is available from several sources. In a joint effort, US EPA and Bayer Schering Pharma with funding from the EU-sponsored 6th framework project, ReProTect, developed a model protocol for such a binding assay. Important features of this assay are the use of a full length hr-ERalpha and performance in a 96-well plate format. A full length hr-ERalpha was chosen, as it was considered to provide the most accurate and human-relevant results, whereas truncated receptors could perform differently. Besides three reference compounds [17beta-estradiol, norethynodrel, dibutylphthalate] nine test compounds with different affinities for the ERalpha [diethylstilbestrol (DES), ethynylestradiol, meso-hexestrol, equol, genistein, o,p'-DDT, nonylphenol, n-butylparaben, and corticosterone] were used to explore the performance of the assay. Three independent experiments per compound were performed on different days, and dilutions of test compounds from deep-frozen stocks, solutions of radiolabeled ligand and receptor preparation were freshly prepared for each experiment. The ERalpha binding properties of reference and test compounds were well detected. As expected dibutylphthalate and corticosterone were non-binders in this assay. In terms of the relative ranking of binding affinities, there was good agreement with published data obtained from experiments using a human recombinant ERalpha ligand binding domain. Irrespective of the chemical nature of the compound, individual IC(50)-values for a given compound varied by not more than a factor of 2.5. Our data demonstrate that the assay was robust and reliably ranked compounds with strong, weak, and no affinity for the ERalpha with high accuracy. It avoids the manipulation and use of animals, i.e., the preparation of uterine cytosol as

  10. Proliferation risks

    International Nuclear Information System (INIS)

    Carchon, R.

    1998-09-01

    The report gives an overview of different aspects related to safeguards of fissile materials. Existing treaties including the Non-Proliferation Treaty, and the Tlatelolco and the Rarotonga Treaties are discussed. An overview of safeguards systems for the control of fissile materials as well as the role of various authorities is given. An overall overview of proliferation risks, the physical protection of fissile materials and the trade in fissile materials is given. Finally, the status in problem countries and de facto nuclear weapon states is discussed

  11. Optimization and development of a high-performance liquid chromatography-based one-site immunometric assay with chemiluminescence detection

    International Nuclear Information System (INIS)

    Oates, Matthew R.; Clarke, William; Zimlich, Alden; Hage, David S.

    2002-01-01

    Various practical and theoretical considerations were examined in the creation and optimization of a high-performance liquid chromatography (HPLC)-based one-site immunometric assay. This method used an HPLC analyte analog column and post-column chemiluminescence detection. The specific analyte chosen as the model for this study was L-thyroxine (also known as T 4 ). In this technique, a sample containing thyroxine was first combined with an excess of anti-T 4 antibody Fab fragments that had earlier been conjugated with chemiluminescent acridinium ester labels. After incubation, the mixture was injected onto a column that contained immobilized T 4 . The amount of thyroxine in the original sample was then determined by measuring the labeled Fab fragments that appeared in the non-retained fraction, or the decrease in excess Fab fragments that were bound to and later eluted from the column. Items considered in creating this assay included the preparation of acridinium ester-labeled Fab fragments, the detection of these fragments with a post-column reactor, and the creation of a suitable immobilized analog column for capturing excess labeled Fab fragments. The final method could measure T 4 in standards at clinically-relevant concentrations and provided a response within 1.5 min of sample injection, following a 20-45 min incubation with the labeled Fab fragments. Possible applications of this method include its use in clinical chemistry and the screening of proteomic or combinatorial libraries

  12. A high-performance liquid chromatography-based radiometric assay for acyl-CoA:alcohol transacylase from jojoba.

    Science.gov (United States)

    Garver, W S; Kemp, J D; Kuehn, G D

    1992-12-01

    Acyl-CoA:alcohol transacylase catalyzes the final step in the biosynthesis of storage liquid wax esters from acyl-CoA fatty acids and fatty alcohols in a limited number of microbes, algae, and Simmondsia chinensis Link (jojoba). An improved and automated method of enzyme assay for this catalyst from cotyledons of jojoba is described. The assay method uses reversed-phase C18 high performance liquid chromatography (HPLC) to separate the labeled C30:1 liquid wax product, [14C]-dodecanyl-octadecenoate, from the unreacted substrate, [14C]octadecenoyl-CoA (oleyl-CoA), and other components produced from enzymes present in the crude homogenate of jojoba cotyledons, including [14C]-octadecenoic acid (oleic acid) and [14C]octadecenol (oleyol). Methods are also described for microscale chemical synthesis in one vessel of 14C-radiolabeled substrates and products for the transacylase. These labeled reagents are required to confirm the HPLC separations of reaction products. The radioactive components are quantitated using an on-line flow-through scintillation detector enabling sensitive and precise analysis of the reaction products.

  13. High-performance liquid chromatographic assay for two rifamycin-derived hypocholesterolemic agents in liver and biological fluids.

    Science.gov (United States)

    Moore, D J; Perrino, P J; Klerer, C P; Robertson, P

    1993-02-26

    CGP 43371 (compound I), a mono-pivaloyl oxazole derivative of a 3-piperazino-rifamycin, has been in clinical trials as a potential hypocholesterolemic agent. A reversed-phase high-performance liquid chromatographic (HPLC) assay was developed using a C18 column and a gradient solvent system of methanol-0.1 M sodium acetate, pH 4.5, at a flow-rate of 1 ml/min. The compound and internal standard (rifampicin) were detected by their ultraviolet absorption at 254 nm. Isolation of the compounds from plasma and liver homogenates was accomplished by precipitation of proteins with acetonitrile, followed by evaporation under nitrogen and reconstitution in methanol. Bile, lymph and urine were injected onto the HPLC column without pretreatment. Calibration curves were linear (r > 0.999) over the concentration range 0.25-20.0 micrograms/ml. The assay procedure was also applicable to other rifamycin derivatives and was able to distinguish between molecular species containing small differences in functionality.

  14. Performance of an ELISA and Indirect Immunofluorescence Assay in Serological Diagnosis of Zoonotic Cutaneous Leishmaniasis in Iran

    Directory of Open Access Journals (Sweden)

    Bahador Sarkari

    2014-01-01

    Full Text Available Serological assays have been extensively evaluated for diagnosis of visceral leishmaniasis (VL and considered as a routine method for diagnosis of VL while these methods are not properly evaluated for diagnosis of cutaneous leishmaniasis (CL. This study aimed to assess the performance of indirect immunofluorescent-antibody test (IFA and enzyme-linked immunosorbent assay (ELISA for serodiagnosis of cutaneous leishmaniasis in Iran. Sixty-one sera samples from parasitologically confirmed CL patients and 50 sera from healthy controls along with 50 sera from non-CL patients were collected. Antigen was prepared from promastigotes and amastigotes of Leishmania major. IFA was used to detect anti-Leishmania IgG while ELISA was used to detect anti-Leishmania IgM, total IgG, or IgG subclasses (IgG1 and 4. ELISA, for detection of total IgG and IgM, showed sensitivity of 83.6% and 84.7% and specificity of 62.7% and 54.6%, respectively. Sensitivity and specificity of ELISA for detecting IgG1 and IgG4 were 64%, 75% and 85%, 49%, respectively. Sensitivity and specificity of IFA were 91.6% and 81%. Conclusion. Findings of this study demonstrated that serological test, especially IFA, can be used for proper diagnosis of CL.

  15. A high performance liquid chromatographic assay of Mefloquine in saliva after a single oral dose in healthy adult Africans

    Directory of Open Access Journals (Sweden)

    Gbotosho Grace O

    2012-02-01

    Full Text Available Abstract Background Mefloquine-artesunate is a formulation of artemisinin based combination therapy (ACT recommended by the World Health Organization and historically the first ACT used clinically. The use of ACT demands constant monitoring of therapeutic efficacies and drug levels, in order to ensure that optimum drug exposure is achieved and detect reduced susceptibility to these drugs. Quantification of anti-malarial drugs in biological fluids other than blood would provide a more readily applicable method of therapeutic drug monitoring in developing endemic countries. Efforts in this study were devoted to the development of a simple, field applicable, non-invasive method for assay of mefloquine in saliva. Methods A high performance liquid chromatographic method with UV detection at 220 nm for assaying mefloquine in saliva was developed and validated by comparing mefloquine concentrations in saliva and plasma samples from four healthy volunteers who received single oral dose of mefloquine. Verapamil was used as internal standard. Chromatographic separation was achieved using a Hypersil ODS column. Results Extraction recoveries of mefloquine in plasma or saliva were 76-86% or 83-93% respectively. Limit of quantification of mefloquine was 20 ng/ml. Agreement between salivary and plasma mefloquine concentrations was satisfactory (r = 0.88, p Conclusion Disposition of mefloquine in saliva paralleled that in plasma, making salivary quantification of mefloquine potentially useful in therapeutic drug monitoring.

  16. Validation of Non-Invasive Waste Assay System (Gamma Box Counter) Performance at AECL Whiteshell Laboratories - 13136

    International Nuclear Information System (INIS)

    Attas, E.M.; Bialas, E.; Rhodes, M.J.

    2013-01-01

    Low-level radioactive waste (LLW) in solid form, resulting from decommissioning and operations activities at AECL's Whiteshell Laboratories (WL), is packaged in B-25 and B-1000 standard waste containers and characterized before it is shipped to an on-site interim storage facility, pending AECL decisions on long term management of its LLW. Assay of the waste packages before shipment contributes to an inventory of the interim storage facility and provides data to support acceptance at a future repository. A key characterization step is a gamma spectrometric measurement carried out under standard conditions using an automated, multi-detector Waste Assay System (WAS), purchased from Antech Corporation. A combination of ORTEC gamma acquisition software and custom software is used in this system to incorporate multiple measurements from two collimated high-resolution detectors. The software corrects the intensities of the gamma spectral lines for geometry and attenuation, and generates a table of calculated activities or limits of detection for a user-defined list of radioisotopes that may potentially be present. Validation of WAS performance was a prerequisite to routine operation. Documentation of the validation process provides assurance of the quality of the results produced, which may be needed one or two decades after they were generated. Aspects of the validation included setting up a quality control routine, measurements of standard point sources in reproducible positions, study of the gamma background, optimization of user-selectable software parameters, investigation of the effect of non-uniform distribution of materials and radionuclides, and comparison of results with measurements made using other gamma detector systems designed to assay bulk materials. The following key components of the validation process have been established. A daily quality control routine has been instituted, to verify stability of the gamma detector operation and the background levels

  17. A Low-Cost, High-Performance System for Fluorescence Lateral Flow Assays

    Directory of Open Access Journals (Sweden)

    Linda G. Lee

    2013-10-01

    Full Text Available We demonstrate a fluorescence lateral flow system that has excellent sensitivity and wide dynamic range. The illumination system utilizes an LED, plastic lenses and plastic and colored glass filters for the excitation and emission light. Images are collected on an iPhone 4. Several fluorescent dyes with long Stokes shifts were evaluated for their signal and nonspecific binding in lateral flow. A wide range of values for the ratio of signal to nonspecific binding was found, from 50 for R-phycoerythrin (R-PE to 0.15 for Brilliant Violet 605. The long Stokes shift of R-PE allowed the use of inexpensive plastic filters rather than costly interference filters to block the LED light. Fluorescence detection with R-PE and absorbance detection with colloidal gold were directly compared in lateral flow using biotinylated bovine serum albumen (BSA as the analyte. Fluorescence provided linear data over a range of 0.4–4,000 ng/mL with a 1,000-fold signal change while colloidal gold provided non-linear data over a range of 16–4,000 ng/mL with a 10-fold signal change. A comparison using human chorionic gonadotropin (hCG as the analyte showed a similar advantage in the fluorescent system. We believe our inexpensive yet high-performance platform will be useful for providing quantitative and sensitive detection in a point-of-care setting.

  18. Immunodiagnosis of Human Fascioliasis: An Update of Concepts and Performances of the Serological Assays

    Science.gov (United States)

    Khabisi, Samaneh Abdolahi

    2017-01-01

    Human Fascioliasis (HF) is a foodborne neglected parasitic disease caused by Fasciola hepatica and Fasciola gigantica. New epidemiological data suggest that the endemic areas of the disease are expanding and HF is being reported from areas where it was previously not observed. Diagnosis of HF is challenging. Performances of parasitological approaches, based on the detection of parasite’s egg in the stool, are not satisfactory. Currently serological methods for the diagnosis of HF are mainly based on detection of anti-Fasciola antibodies in serum. Although, there have been some improvement in the development of immunological diagnostic tests for the diagnosis of HF, yet these tests suffer from insufficiency in sensitivity or/and specificity. Detection of antigens, rather than antibodies, seems to be a suitable approach in the diagnosis of HF. Antigen can be detected in sera or stool of the fascioliasis patients. Circulating antigen in serum disappears within a short time and most of the circulating antigens are in immune complex forms which are not freely available to be detected. Therefore, antigenemia might not be an appropriate method for the diagnosis of HF. Detection of antigen in stool (coproantigens) seems to be a suitable alternative method for the diagnosis of HF. Recent data provided convincing evidence that detection of coproantigen improved and simplified the diagnosis of HF. The present review highlights the new achievements in designing and improvement of diagnostic approaches for the immunodiagnosis of HF. Moreover, current status of the available immunodiagnostic techniques for the diagnosis of HF, their strengths and weaknesses has been discussed. PMID:28764235

  19. [Evaluation of the Performance of Two Kinds of Anti-TP Enzyme-Linked Immunosorbent Assay].

    Science.gov (United States)

    Gao, Nan; Huang, Li-Qin; Wang, Rui; Jia, Jun-Jie; Wu, Shuo; Zhang, Jing; Ge, Hong-Wei

    2018-06-01

    To evaluate the accuracy and precision of 2 kinds of anti-treponema pallidum (anti-TP) ELISA reagents in our laboratory for detecting the anti-TP in voluntary blood donors, so as to provide the data support for use of ELISA reagents after introduction of chemiluminescene immunoassay (CLIA). The route detection of anti-TP was performed by using 2 kinds of ELISA reagents, then 546 responsive positive samples detected by anti-TP ELISA were collected, and the infections status of samples confirmed by treponema pallidum particle agglutination (TPPA) test was identified. The confirmed results of responsive samples detected by 2 kinds of anti-TP ELISA reagents were compared, the accuracy of 2 kinds of anti-TP ELISA reagents was analyzed by drawing ROC and comparing area under curve (AUC), and precision of 2 kinds of anti-TP ELISA reagents was compared by statistical analysis of quality control data from 7.1 2016 to 6.30 2017. There were no statistical difference in confirmed positive rate of responsive samples and weak positive samples between 2 kinds of anti-TP ELISA reagents. The responsive samples detected by 2 kinds of anti-TP ELISA reagents accounted for 85.53%(467/546) of all responsive samples, the positive rate confirmed by TPPA test was 82.87%. 44 responsive samples detected by anti-TP ELISA reagent A and 35 responsive samples detected by anti-TP ELISA reagent B were confirmed to be negative by TPPA test. Comparison of AUC showed that the accuracy of 2 kinds of anti-TP ELISA reagents was more high, the difference between 2 reagents was not statistically significant. The coefficient of variation (CV) of anti-TP ELISA reagent A and B was 14.98% and 18.04% respectively, which met the precision requirement of ELISA test. The accuracy and precision of 2 kinds of anti-TP ELISA reagents used in our laboratory are similar, and using any one of anti-TP ELISA reagents all can satisfy the requirements of blood screening.

  20. A high-performance liquid chromatography method for the serotonin release assay is equivalent to the radioactive method.

    Science.gov (United States)

    Sono-Koree, N K; Crist, R A; Frank, E L; Rodgers, G M; Smock, K J

    2016-02-01

    The serotonin release assay (SRA) is considered the gold standard laboratory test for heparin-induced thrombocytopenia (HIT). The historic SRA method uses platelets loaded with radiolabeled serotonin to evaluate platelet activation by HIT immune complexes. However, a nonradioactive method is desirable. We report the performance characteristics of a high-performance liquid chromatography (HPLC) SRA method. We validated the performance characteristics of an HPLC-SRA method, including correlation with a reference laboratory using the radioactive method. Serotonin released from reagent platelets was quantified by HPLC using fluorescent detection. Results were expressed as % release and classified as positive, negative, or indeterminate based on previously published cutoffs. Serum samples from 250 subjects with suspected HIT were tested in the HPLC-SRA and with the radioactive method. Concordant classifications were observed in 230 samples (92%). Sera from 41 healthy individuals tested negative. Between-run imprecision studies showed standard deviation of performance characteristics, equivalent to the historic radioactive method, but avoids the complexities of working with radioactivity. © 2015 John Wiley & Sons Ltd.

  1. Traceability Assessment and Performance Evaluation of Results for Measurement of Abbott Clinical Chemistry Assays on 4 Chemistry Analyzers.

    Science.gov (United States)

    Lim, Jinsook; Song, Kyung Eun; Song, Sang Hoon; Choi, Hyun-Jung; Koo, Sun Hoe; Kwon, Gye Choel

    2016-05-01

    -The traceability of clinical results to internationally recognized and accepted reference materials and reference measurement procedures has become increasingly important. Therefore, the establishment of traceability has become a mandatory requirement for all in vitro diagnostics devices. -To evaluate the traceability of the Abbott Architect c8000 system (Abbott Laboratories, Abbott Park, Illinois), consisting of calibrators and reagents, across 4 different chemistry analyzers, and to evaluate its general performance on the Toshiba 2000FR NEO (Toshiba Medical Systems Corporation, Otawara-shi, Tochigi-ken, Japan). -For assessment of traceability, secondary reference materials were evaluated 5 times, and then bias was calculated. Precision, linearity, and carryover were determined according to the guidelines of the Clinical and Laboratory Standards Institute (Wayne, Pennsylvania). -The biases from 4 different analyzers ranged from -2.33% to 2.70% on the Toshiba 2000FR NEO, -2.33% to 5.12% on the Roche Hitachi 7600 (Roche Diagnostics International, Basel, Switzerland), -0.93% to 2.87% on the Roche Modular, and -2.16% to 2.86% on the Abbott Architect c16000. The total coefficients of variance of all analytes were less than 5%. The coefficients of determination (R(2)) were more than 0.9900. The carryover rate ranged from -0.54% to 0.17%. -Abbott clinical chemistry assays met the performance criteria based on desirable biological variation for precision, bias, and total error. They also showed excellent linearity and carryover. Therefore, these clinical chemistry assays were found to be accurate and reliable and are readily applicable on the various platforms used in this study.

  2. Multi-laboratory evaluations of the performance of Catellicoccus marimammalium PCR assays developed to target gull fecal sources

    Science.gov (United States)

    Sinigalliano, Christopher D.; Ervin, Jared S.; Van De Werfhorst, Laurie C.; Badgley, Brian D.; Ballestée, Elisenda; Bartkowiaka, Jakob; Boehm, Alexandria B.; Byappanahalli, Muruleedhara N.; Goodwin, Kelly D.; Gourmelon, Michèle; Griffith, John; Holden, Patricia A.; Jay, Jenny; Layton, Blythe; Lee, Cheonghoon; Lee, Jiyoung; Meijer, Wim G.; Noble, Rachel; Raith, Meredith; Ryu, Hodon; Sadowsky, Michael J.; Schriewer, Alexander; Wang, Dan; Wanless, David; Whitman, Richard; Wuertz, Stefan; Santo Domingo, Jorge W.

    2013-01-01

    Here we report results from a multi-laboratory (n = 11) evaluation of four different PCR methods targeting the 16S rRNA gene of Catellicoccus marimammalium originally developed to detect gull fecal contamination in coastal environments. The methods included a conventional end-point PCR method, a SYBR® Green qPCR method, and two TaqMan® qPCR methods. Different techniques for data normalization and analysis were tested. Data analysis methods had a pronounced impact on assay sensitivity and specificity calculations. Across-laboratory standardization of metrics including the lower limit of quantification (LLOQ), target detected but not quantifiable (DNQ), and target not detected (ND) significantly improved results compared to results submitted by individual laboratories prior to definition standardization. The unit of measure used for data normalization also had a pronounced effect on measured assay performance. Data normalization to DNA mass improved quantitative method performance as compared to enterococcus normalization. The MST methods tested here were originally designed for gulls but were found in this study to also detect feces from other birds, particularly feces composited from pigeons. Sequencing efforts showed that some pigeon feces from California contained sequences similar to C. marimammalium found in gull feces. These data suggest that the prevalence, geographic scope, and ecology of C. marimammalium in host birds other than gulls require further investigation. This study represents an important first step in the multi-laboratory assessment of these methods and highlights the need to broaden and standardize additional evaluations, including environmentally relevant target concentrations in ambient waters from diverse geographic regions.

  3. Comparison among performances of a ligase chain reaction-based assay and two enzyme immunoassays in detecting Chlamydia trachomatis in urine specimens from men with nongonococcal urethritis.

    Science.gov (United States)

    Deguchi, T; Yasuda, M; Uno, M; Tada, K; Iwata, H; Komeda, H; Maeda, S; Latila, V; Saito, I; Kawada, Y

    1996-01-01

    We evaluated the performances of a ligase chain reaction (LCR)-based assay and two enzyme immunoassays (Chlamydiazyme and IDEIA) in the detection of Chlamydia trachomatis in urine specimens. We compared the results of testing urine specimens by these assays with those of urethral swab culture by examining samples from 131 men with nongonococcal urethritis. Discrepant results were analyzed by testing urethral swab specimens for C. trachomatis by a PCR-based assay. After the resolution of discrepant results, the sensitivity of urethral swab culture was 85.3%, whereas those of the LCR assay, Chlamydiazyme, and IDEIA with urine specimens were 94.1, 82.4, and 94.1%, respectively. The LCR assay and IDEIA were more sensitive than was urethral swab culture. In addition, the LCR assay, with a sensitivity equal to that of IDEIA, was more specific. Overall, the LCR assay proved to be superior to the enzyme immunoassays in detecting C. trachomatis in urine specimens. Testing urine specimens by LCR assay should be a helpful alternative method for diagnosing C. trachomatis urethral infection in men with nongonococcal urethritis. PMID:8784574

  4. IAEA safeguards: Stemming the spread of nuclear weapons. As the world's nuclear inspectorate, the IAEA performs an indispensable role in furthering nuclear non-proliferation

    International Nuclear Information System (INIS)

    2002-01-01

    Following the completion of the Treaty on the Non- Proliferation of Nuclear Weapons (NPT) in 1968, the IAEA has become the instrument with which to verify that the peaceful use commitments made under the NPT or similar agreements are kept through performing what is known as its safeguards role. Under the NPT, governments around the world have committed to three common objectives: preventing the proliferation of nuclear weapons; pursuing nuclear disarmament; and promoting the peaceful uses of nuclear energy. The NPT has made it obligatory for all its non-nuclear weapon State parties to submit all nuclear material in nuclear activities to IAEA safeguards, and to conclude a comprehensive safeguards agreement with the Agency. With all but a handful of the world community as State parties, the NPT is by far the most widely adhered to legal agreement in the field of disarmament and non-proliferation. The IAEA takes account of all source and special fissionable material in countries under safeguards. Monitoring and verification activities focus on those types of nuclear material that are the most crucial and relevant to nuclear weapons manufacturing. This includes plutonium-239, uranium-233 and -235 and any material containing one or more of these. Safeguards activities are applied routinely at over 900 facilities in 71 countries. In 2001 alone, more than 21,000 calendar days in the field were devoted to verifying hundreds of tons of special fissionable material by more than IAEA 250 inspectors

  5. Nuclear proliferation

    International Nuclear Information System (INIS)

    Stencel, S.

    1978-01-01

    The terms and reactions to President Carter's nuclear policy, culminating in the 1978 Nuclear Non-Proliferation Act, are reviewed and analyzed. The new law increases restrictions on nuclear exports, encourages continued use of light water reactors in preference to plutonium-fueled reactors, and emphasizes technical solutions to proliferation problems. Critics of the law point out that it will hurt U.S. trade unfairly, that other countries do not have as many fuel options as the U.S. has, and that nuclear sales have as many political and economic as technical solutions. Compromise areas include new international safety guidelines, the possibility of an international nuclear fuel bank, and a willingness to consider each case on its merits. 21 references

  6. Performance of two Aspergillus IgG EIA assays compared with the precipitin test in chronic and allergic aspergillosis.

    Science.gov (United States)

    Baxter, C G; Denning, D W; Jones, A M; Todd, A; Moore, C B; Richardson, M D

    2013-04-01

    Detection of Aspergillus IgG antibodies is important in the diagnosis of chronic pulmonary aspergillosis and allergic bronchopulmonary aspergillosis. Immunoprecipitation techniques to detect these antibodies appear to lack sensitivity and accurate quantitation compared with enzyme immunoassays (EIA). This study assessed the performance of two commercial EIAs compared with counterimmunoelectrophoresis (CIE). This was a prospective cohort study of 175 adult patients with chronic or allergic pulmonary aspergillosis. Aspergillus IgG antibodies were detected using CIE, Phadia ImmunoCap Aspergillus IgG and Bio-Rad Platelia Aspergillus IgG. Inter-assay reproducibility was determined for each method and 25 patients had two serum samples analysed within a 6-month interval. When compared with CIE, both ImmunoCap and Platelia Aspergillus IgG had good sensitivity (97 and 93%, respectively) for detection of Aspergillus IgG antibodies. The level of agreement between the two EIAs for positive results was good, but the concentration of antibodies was not correlated between the tests or with CIE titre. ImmunoCap IgG inter-assay coefficient of variation was 5%, whereas Platelia IgG was 33%. Median ImmunoCap IgG values for CPA and allergic aspergillosis were 95 and 32 mg/L, respectively, whereas Platelia IgG values were >80 and 6 AU/mL. The direction of CIE titre change over 6 months was mirrored by ImmunoCap IgG levels in 92% of patients, and by Platelia IgG in 72% of patients. Both ImmunoCap and Platelia Aspergillus IgG EIAs are sensitive measures of Aspergillus IgG antibodies compared with CIE. However, ImmunoCap appears to have better reproducibility and may be more suitable for monitoring patient disease. © 2012 The Authors Clinical Microbiology and Infection © 2012 European Society of Clinical Microbiology and Infectious Diseases.

  7. Translating tumor biology into personalized treatment planning: analytical performance characteristics of the Oncotype DX? Colon Cancer Assay

    OpenAIRE

    Clark-Langone, Kim M; Sangli, Chithra; Krishnakumar, Jayadevi; Watson, Drew

    2010-01-01

    Abstract Background The Oncotype DX® Colon Cancer Assay is a new diagnostic test for determining the likelihood of recurrence in stage II colon cancer patients after surgical resection using fixed paraffin embedded (FPE) primary colon tumor tissue. Like the Oncotype DX Breast Cancer Assay, this is a high complexity, multi-analyte, reverse transcription (RT) polymerase chain reaction (PCR) assay that measures the expression levels of specific cancer-related genes. By capturing the biology unde...

  8. High-performance liquid chromatographic assay of parabens in wash-off cosmetic products and foods using chemiluminescence detection

    International Nuclear Information System (INIS)

    Zhang Qunlin; Lian Mei; Liu Lijuan; Cui Hua

    2005-01-01

    A new method for the simultaneous determination of parabens including methylparaben, ethylparaben, propylparaben, and butylparaben by high-performance liquid chromatography (HPLC) coupled with chemiluminescence detection was developed. The procedure was based on the chemiluminescent enhancement by parabens of the cerium(IV)-rhodamine 6G system in the strong sulfuric acid medium. The good separation of parabens was carried out with an isocratic elution using a mixture of methanol and water (60:40, v/v) within 8.5 min. Under the optimized conditions, a linear working range extends three orders of magnitude with the relative standard deviations of intra- and inter-day precision below 4.5%, and the detection limits were 1.9 x 10 -9 , 2.7 x 10 -9 , 3.9 x 10 -9 , and 5.3 x 10 -9 g ml -1 for methylparaben, ethylparaben, propylparaben, and butylparaben, respectively. The chemiluminescence reaction was well compatible with the mobile phase of high-performance liquid chromatography. The proposed method has been successfully applied to the assay of parabens in wash-off cosmetic products and foods with the minimal sample preparation

  9. SOX15 regulates proliferation and migration of endometrial cancer cells.

    Science.gov (United States)

    Rui, Xiaohui; Xu, Yun; Jiang, Xiping; Guo, Caixia; Jiang, Jingting

    2017-10-31

    The study aimed to investigate the effects of Sry-like high mobility group box 15 ( SOX15 ) on proliferation and migration of endometrial cancer (EC) cells. Immunohistochemistry (IHC) was applied to determine the expression of SOX15 in EC tissues and adjacent tissues. We used cell transfection method to construct the HEC-1-A and Ishikawa cell lines with stable overexpression and low expression SOX15 Reverse-transcription quantitative real-time PCR (RT-qPCR) and Western blot were performed to examine expression of SOX15 mRNA and SOX15 protein, respectively. By conducting a series of cell proliferation assay and migration assay, we analyzed the influence of SOX15 overexpression or low expression on EC cell proliferation and migration. The expression of SOX15 mRNA and protein in EC tissues was significantly lower than that in adjacent tissues. After lentivirus-transfecting SOX15 , the expression level of SOX15 mRNA and protein was significantly increased in cells of SOX15 group, and decreased in sh- SOX15 group. Overexpression of SOX15 could suppress cell proliferation, while down-regulation of SOX15 increased cell proliferation. Flow cytometry results indicated that overexpression of SOX15 induced the ratio of cell-cycle arrest in G 1 stage. In addition, Transwell migration assay results showed that SOX15 overexpression significantly inhibited cell migration, and also down-regulation of SOX15 promoted the migration. As a whole, SOX15 could regulate the proliferation and migration of EC cells and up- regulation of SOX15 could be valuable for EC treatment. © 2017 The Author(s).

  10. Performance evaluation of the Aptima HSV-1 and 2 assay for the detection of HSV in cutaneous and mucocutaneous lesion specimens.

    Science.gov (United States)

    Sam, Soya S; Caliendo, Angela M; Ingersoll, Jessica; Abdul-Ali, Deborah; Kraft, Colleen S

    Timely and precise laboratory diagnosis of Herpes simplex viruses (HSV) is required to guide clinical management. The study evaluated limit of detection (LOD) and performance characteristics of the Aptima HSV 1 & 2 assay in comparison to four assays. The multi-center study compared qualitative detection of HSV-1 and 2 by the Aptima HSV-1 and 2 assay (Hologic) to ELVIS culture, Lyra Direct (Quidel), AmpliVue (Quidel) and a laboratory developed test (LDT). LOD was performed using VTM and STM diluted viral concentrations and clinical performance was evaluated using 505 swab specimens. The Aptima LOD studies performed showed a lower detection limit for STM specimens as 1450 copies/mL and 430 copies/mL for HSV1 and HSV-2 respectively; the LOD for VTM specimens was 9370 copies/mL and 8045 copies/mL for HSV-1 and HSV-2 respectively. When the assays were analyzed based on the positive consensus result established the Aptima had 95% of percent positive agreement (PPA) and 100% negative percent agreement (NPA) for the HSV-1. For the HSV-2, the PPA and NPA for Aptima were 96% and 100% respectively. AmpliVue had 1.8% invalid rate, while Lyra had no invalid results but an inhibition rate of 0.8%. Aptima and LDT did not have any invalid or inhibited results. The results indicate that the Aptima HSV-1 & 2 assay is sensitive and the performance characteristics of the Aptima assay is comparable to the assays analyzed for the detection and differentiation of HSV-1 and 2 from cutaneous and mucocutaneous lesions. Copyright © 2017 Elsevier B.V. All rights reserved.

  11. Highly sensitive reversed-phase high-performance liquid chromatography assay for the detection of Tamm-Horsfall protein in human urine.

    Science.gov (United States)

    Akimoto, Masaru; Hokazono, Eisaku; Ota, Eri; Tateishi, Takiko; Kayamori, Yuzo

    2016-01-01

    Tamm-Horsfall protein (also known as uromodulin) is the most abundant urinary protein in healthy individuals. Since initially characterized by Tamm and Horsfall, the amount of urinary excretion and structural mutations of Tamm-Horsfall protein is associated with kidney diseases. However, currently available assays for Tamm-Horsfall protein, which are mainly enzyme-linked immunosorbent assay-based, suffer from poor reproducibility and might give false negative results. We developed a novel, quantitative assay for Tamm-Horsfall protein using reversed-phase high-performance liquid chromatography. A precipitation pretreatment avoided urine matrix interference and excessive sample dilution. High-performance liquid chromatography optimization based on polarity allowed excellent separation of Tamm-Horsfall protein from other major urine components. Our method exhibited high precision (based on the relative standard deviations of intraday [≤2.77%] and interday [≤5.35%] repetitions). The Tamm-Horsfall protein recovery rate was 100.0-104.2%. The mean Tamm-Horsfall protein concentration in 25 healthy individuals was 31.6 ± 18.8 mg/g creatinine. There was a strong correlation between data obtained by high-performance liquid chromatography and enzyme-linked immunosorbent assay (r = 0.906), but enzyme-linked immunosorbent assay values tended to be lower than high-performance liquid chromatography values at low Tamm-Horsfall protein concentrations. The high sensitivity and reproducibility of our Tamm-Horsfall protein assay will reduce the number of false negative results of the sample compared with enzyme-linked immunosorbent assay. Moreover, our method is superior to other high-performance liquid chromatography methods, and a simple protocol will facilitate further research on the physiological role of Tamm-Horsfall protein. © The Author(s) 2015.

  12. Performance of 2 commercial real-time polymerase chain reaction assays for the detection of Aspergillus and Pneumocystis DNA in bronchoalveolar lavage fluid samples from critical care patients.

    Science.gov (United States)

    Orsi, Carlotta Francesca; Gennari, William; Venturelli, Claudia; La Regina, Annunziata; Pecorari, Monica; Righi, Elena; Machetti, Marco; Blasi, Elisabetta

    2012-06-01

    This article investigates the performance of 2 commercial real-time polymerase chain reaction (PCR) assays, MycAssay™ Aspergillus (Myc(Asp)Assay) and MycAssay™ Pneumocystis (Myc(PCP)Assay), on the ABI 7300 platform for the detection of Aspergillus (Asp) or Pneumocystis jirovecii (Pj) DNA in bronchoalveolar lavage (BAL) samples from 20 patients. Operationally, patients enrolled were clustered into 3 groups: invasive aspergillosis group (IA, 7 patients), Pj pneumonia group (PCP, 8 patients), and negative control group (5 patients). All the IA patients were Myc(Asp)Assay positive, whereas 12 non-IA patients returned negative PCR results. Furthermore, 7 of 8 PCP patients were Myc(PCP)Assay positive, while 9 non-PCP patients were PCR negative. In conclusion, these data provide an early indication of the effectiveness of both the Myc(Asp)Assay and Myc(PCP)Assay on the ABI 7300 platform for the detection of either Asp or Pj DNA in BAL from patients with deep fungal infections. Copyright © 2012 Elsevier Inc. All rights reserved.

  13. Comparison of the performance in detection of HPV infections between the high-risk HPV genotyping real time PCR and the PCR-reverse dot blot assays.

    Science.gov (United States)

    Zhang, Lahong; Dai, Yibei; Chen, Jiahuan; Hong, Liquan; Liu, Yuhua; Ke, Qiang; Chen, Yiwen; Cai, Chengsong; Liu, Xia; Chen, Zhaojun

    2018-01-01

    A new multiplex real-time PCR assay, the high-risk HPV genotyping real time PCR assay (HR HPV RT-PCR), has been developed to detect 15 high-risk HPV types with respective viral loads. In this report, a total of 684 cervical specimens from women diagnosed with vaginitis were assessed by the HR HPV RT-PCR and the PCR reaction and reverse dot blot (PCR-RDB) assays, using a PCR-sequencing method as a reference standard. A total coincidence of 97.7% between the HR HPV RT PCR and the PCR-RDB assays was determined with a Kappa value of 0.953. The HR HPV RT PCR assay had sensitivity, specificity, and concordance rates (accuracy) of 99.7%, 99.7%, and 99.7%, respectively, as confirmed by PCR-sequencing, while the PCR-RDB assay had respective rates of 98.8%, 97.1%, and 98.0%. The overall rate of HPV infection, determined by PCR-sequencing, in women diagnosed with vaginitis was 49.85%, including 36.26% of single infection and 13.6% of multiple infections. The most common infections among the 15 high-risk HPV types in women diagnosed with vaginitis were HPV-52, HPV-16, and HPV-58, with a total detection rate of 10.23%, 7.75%, and 5.85%, respectively. We conclude that the HR HPV RT PCR assay exhibits better clinical performance than the PCR-RDB assay, and is an ideal alternative method for HPV genotyping. In addition, the HR HPV RT PCR assay provides HPV DNA viral loads, and could serve as a quantitative marker in the diagnosis and treatment of single and multiple HPV infections. © 2017 Wiley Periodicals, Inc.

  14. Factor VII assay performance: an analysis of the North American Specialized Coagulation Laboratory Association proficiency testing results.

    Science.gov (United States)

    Zantek, N D; Hsu, P; Refaai, M A; Ledford-Kraemer, M; Meijer, P; Van Cott, E M

    2013-06-01

    The performance of factor VII (FVII) assays currently used by clinical laboratories was examined in North American Specialized Coagulation Laboratory Association (NASCOLA) proficiency tests. Data from 12 surveys conducted between 2008 and 2010, involving 20 unique specimens plus four repeat-tested specimens, were analyzed. The number of laboratories per survey was 49-54 with a total of 1224 responses. Numerous reagent/instrument combinations were used. For FVII > 80 or 50 U/dL, among commonly used methods, one thromboplastin and one calibrator produced results 5-6 U/dL higher and another thromboplastin and calibrator produced results 5-6 U/dL lower than all other methods, and human thromboplastin differed from rabbit by +7.6 U/dL. Preliminary evidence suggests these differences could be due to the calibrator. For FVII <50 U/dL, differences among the commonly used reagents and calibrators were generally not significant. © 2013 Blackwell Publishing Ltd.

  15. [Comparison of the performance of the ECLusys anti-HCV reagent with the Lumipulse f and HISCL 2000-i HCVAb assays].

    Science.gov (United States)

    Sugiura, Aya; Iwahara, Kunihiro; Suga, Yasuyuki; Uchiyama, Sachinori; Maekawa, Masato

    2012-09-01

    We compared the ECLusys Anti-HCV (ECL) reagent to the Lumipulse f (LPf) and HISCL (HIS) HCV assays. In a correlation test using 210 routine clinical specimens measured using the Lumipulse method (96 positive and 114 negative), most of the results were consistent for all specimens. In a dilution sensitivity test using three different routine positive specimens, the ECL assay enabled detection at higher levels of sensitivity than either the LPf or the HIS assay. Moreover, when the distribution of the cut-off index (C.O.I.) values of the routine LPf negative specimens were compared to those on the ECL and HIS assays, it was found that on the ECL assay, most of the specimens had cut-off index values < 0.1, indicating a more clear-cut distribution. In a specificity test using high RF positive specimens(n = 33), pregnancy specimens (n = 35), cytomegalovirus (CMV) antibody positive specimens (n = 36), and high M protein positive specimens (n = 21), the ECL assay yielded positive results for a CMV antibody positive specimen and three high M protein positive specimens. Further testing using samples from the same patients collected on different days than these four samples resulted in a second positive result for the CMV positive specimen, and single antigen measurement yielded a Core/NS3 positive result, as well, suggesting past infection. However, since negative results were obtained for the three M protein positive specimens, the possibility of this being a ECLusys non-specific reaction could not be ruled out. The above results confirmed that the ECL assay provides superior fundamental performance, and possesses test performance nearly identical to that of the existing measurement methods that are widely used at a large number of facilities, and would therefore be a suitable assay for use in routine HCV antibody screening.

  16. Performance evaluation of a novel chemiluminescence assay for detection of anti-GBM antibodies: an international multicenter study.

    Science.gov (United States)

    Mahler, Michael; Radice, Antonella; Sinico, Renato A; Damoiseaux, Jan; Seaman, Andrea; Buckmelter, Kristen; Vizjak, Alenka; Buchner, Carol; Binder, Walter L; Fritzler, Marvin J; Cui, Zhao

    2012-01-01

    Autoantibodies to the non-collagen region (NC1) of the alpha-3 subunit of collagen IV represent a serological hallmark in the diagnosis of Goodpasture's syndrome (GPS). The objective of our study was to carefully analyze the performance characteristics of a novel anti-glomerular basement membrane (GBM) chemiluminescence immunoassay (CIA). Sera from patients with GPS (n = 90) were collected from four clinical centers. Samples from different disease groups (n = 397) and healthy individuals (n = 400) were used as controls. All samples were tested for anti-GBM antibodies by a rapid, random access CIA (QUANTA Flash™ GBM). Most of the samples were also tested using other methods including different commercial anti-GBM IgG assays and research assays for anti-GBM IgA and IgM. The sensitivity and specificity of the novel CIA was 95.6% [95% confidence interval (CI) 89.0-98.8%] and 99.6% (95% CI 98.9-99.9%), respectively. Receiver operating characteristic analysis showed good discrimination between GPS patients and controls. The area under the curve was 0.98 (CI 0.96-1.0). The three anti-GBM antibody-positive samples from the control group were from two healthy individuals and one human immunodeficiency virus (HIV)-infected patient. All three individuals had low levels of anti-GBM antibodies [20, 24 and 25 chemiluminescent unit (CU), cutoff 20 CU]. When the results of the new CIA were compared to other methods, good agreement was observed: 95.8% (kappa = 0.92) versus EliA™ GBM, 97.4% (kappa = 0.95) versus both BINDAZYME™ Anti-GBM and QUANTA Lite® GBM. Anti-GBM IgA was detectable in low concentrations in patients with GPS and was associated with anti-GBM IgG but was less useful in discriminating GPS patients and controls. No discrimination was found for anti-GBM IgM. The novel QUANTA Flash™ GBM CIA demonstrated good sensitivity and specificity and had good agreement with other methods. Our data confirm that ∼5% of patients with GPS do not have detectable levels of

  17. Factors associated with the performance of a blood-based interferon-γ release assay in diagnosing tuberculosis.

    Directory of Open Access Journals (Sweden)

    Sally Banfield

    Full Text Available BACKGROUND: Indeterminate results are a recognised limitation of interferon-γ release assays (IGRA in the diagnosis of latent tuberculosis (TB infection (LTBI and TB disease, especially in children. We investigated whether age and common co-morbidities were associated with IGRA performance in an unselected cohort of resettled refugees. METHODS: A retrospective cross-sectional study of refugees presenting for their post-resettlement health assessment during 2006 and 2007. Refugees were investigated for prevalent infectious diseases, including TB, and for common nutritional deficiencies and haematological abnormalities as part of standard clinical screening protocols. Tuberculosis screening was performed by IGRA; QuantiFERON-TB Gold in 2006 and QuantiFERON-TBGold In-Tube in 2007. RESULTS: Complete data were available on 1130 refugees, of whom 573 (51% were children less than 17 years and 1041 (92% were from sub-Saharan Africa. All individuals were HIV negative. A definitive IGRA result was obtained in 1004 (89% refugees, 264 (26% of which were positive; 256 (97% had LTBI and 8 (3% had TB disease. An indeterminate IGRA result was obtained in 126 (11% refugees (all failed positive mitogen control. In multivariate analysis, younger age (linear OR= 0.93 [95% CI 0.91-0.95], P<0.001, iron deficiency anaemia (2.69 [1.51-4.80], P = 0.001, malaria infection (3.04 [1.51-6.09], P = 0.002, and helminth infection (2.26 [1.48-3.46], P<0.001, but not vitamin D deficiency or insufficiency, were associated with an indeterminate IGRA result. CONCLUSIONS: Younger age and a number of common co-morbidities are significantly and independently associated with indeterminate IGRA results in resettled predominantly African refugees.

  18. Radiation protection - Performance criteria for laboratories performing cytogenetic triage for assessment of mass casualties in radiological or nuclear emergencies - General principles and application to dicentric assay

    International Nuclear Information System (INIS)

    2008-01-01

    The potential for nuclear and radiological emergencies involving mass casualties from accidental or malicious acts or terrorism requires generic procedures for emergency dose assessment to help the development of medical response capabilities. A mass-casualties incident is defined here as an event that exceeds the local medical resources. Biological dosimetry, based on cytogenetic analysis using the dicentric assay, typically applied for accidental dose assessment, has been defined in ISO 19238. Cytogenetic triage is the use of chromosome damage to evaluate and assess approximately and rapidly radiation doses received by individuals in order to supplement the clinical categorization of casualties. This International Standard focuses on the use of the dicentric assay for rapid cytogenetic triage involving mass-casualty incidents. The primary purpose of this International Standard is to provide a guideline to all laboratories in order to perform the dicentric-bioassay - cytogenetic triage for dose assessment using documented and validated procedures. Secondly, it can facilitate the application of cytogenetic biodosimetry networks to permit comparison of results obtained in different laboratories. Finally, it is expected that laboratories newly commissioned to carry out the cytogenetic triage conform to this International Standard in order to perform the triage reproducibly and accurately. This International Standard is written in the form of procedures to adopt for dicentric-bioassay - cytogenetic triage biological dosimetry for overexposures involving mass radiological casualties. The criteria required for such measurements usually depend on the application of the results: medical management when appropriate, radiation-protection management, record keeping and medical/legal requirements. For example, selected cases can be analysed to produce a more accurate evaluation of high partial-body exposure; secondly, doses can be estimated for persons exposed below the

  19. Preventing proliferation

    International Nuclear Information System (INIS)

    Rathjens, G.

    1983-01-01

    Challenging the argument that nuclear proliferation may be stabilizing, the author cites the Israeli attack on Iraq as evidence that emergent nuclear states may be moved to attack their adversaries.The larger the number of decision makers who can unleash nuclear weapons, the greater the liklihood of their use. Several reasons are cited for nations to seek nuclear capability: the accelerated spread of technology, the deterioration in US-Soviet relations and strength relative to their nations, the high cost of conventional weapons, and a loss of confidence in the international safeguards system. The imposition of constraints, such as a Comprehensive Test Ban Treaty, on nuclear trade and technology transfer are likely to have a high cost. The US position on this issue is likely to be determined by the balance of power with the Soviet Union. 5 references

  20. Selecting the correct weighting factors for linear and quadratic calibration curves with least-squares regression algorithm in bioanalytical LC-MS/MS assays and impacts of using incorrect weighting factors on curve stability, data quality, and assay performance.

    Science.gov (United States)

    Gu, Huidong; Liu, Guowen; Wang, Jian; Aubry, Anne-Françoise; Arnold, Mark E

    2014-09-16

    A simple procedure for selecting the correct weighting factors for linear and quadratic calibration curves with least-squares regression algorithm in bioanalytical LC-MS/MS assays is reported. The correct weighting factor is determined by the relationship between the standard deviation of instrument responses (σ) and the concentrations (x). The weighting factor of 1, 1/x, or 1/x(2) should be selected if, over the entire concentration range, σ is a constant, σ(2) is proportional to x, or σ is proportional to x, respectively. For the first time, we demonstrated with detailed scientific reasoning, solid historical data, and convincing justification that 1/x(2) should always be used as the weighting factor for all bioanalytical LC-MS/MS assays. The impacts of using incorrect weighting factors on curve stability, data quality, and assay performance were thoroughly investigated. It was found that the most stable curve could be obtained when the correct weighting factor was used, whereas other curves using incorrect weighting factors were unstable. It was also found that there was a very insignificant impact on the concentrations reported with calibration curves using incorrect weighting factors as the concentrations were always reported with the passing curves which actually overlapped with or were very close to the curves using the correct weighting factor. However, the use of incorrect weighting factors did impact the assay performance significantly. Finally, the difference between the weighting factors of 1/x(2) and 1/y(2) was discussed. All of the findings can be generalized and applied into other quantitative analysis techniques using calibration curves with weighted least-squares regression algorithm.

  1. Validation and application of a high-performance liquid chromatography--tandem mass spectrometry assay for mosapride in human plasma.

    Science.gov (United States)

    Ramakrishna, N V S; Vishwottam, K N; Manoj, S; Koteshwara, M; Chidambara, J; Varma, D P

    2005-09-01

    A simple, rapid, sensitive and specific liquid chromatography-tandem mass spectrometry method was developed and validated for quantification of mosapride (I), a novel and potent gastroprokinetic agent that enhances the upper gastrointestinal motility by stimulating 5-HT(4) receptor. The analyte and internal standard, tamsulosin (II), were extracted by liquid-liquid extraction with diethyl ether-dichloromethane (70:30, v/v) using a Glas-Col Multi-Pulse Vortexer. The chromatographic separation was performed on a reversed-phase Waters symmetry C(18) column with a mobile phase of 0.03% formic acid-acetonitrile (10:90, v/v). The protonated analyte was quantitated in positive ionization by multiple reaction monitoring with a mass spectrometer. The mass transitions m/z 422.3 -->198.3 and m/z 409.1 -->228.1 were used to measure I and II, respectively. The assay exhibited a linear dynamic range of 0.5-100.0 ng/mL for mosapride in human plasma. The lower limit of quantitation was 500 pg/mL with a relative standard deviation of less than 15%. Acceptable precision and accuracy were obtained for concentrations over the standard curve ranges. A run time of 2.0 min for each sample made it possible to analyze a throughput of more than 400 human plasma samples per day. The validated method has been successfully used to analyze human plasma samples for application in pharmacokinetic, bioavailability or bioequivalence studies. Copyright (c) 2005 John Wiley & Sons, Ltd.

  2. Saccharification Performances of Miscanthus at the Pilot and Miniaturized Assay Scales: Genotype and Year Variabilities According to the Biomass Composition

    Directory of Open Access Journals (Sweden)

    Nassim Belmokhtar

    2017-05-01

    Full Text Available HIGHLIGHTSBiomass production and cell wall composition are differentially impacted by harvesting year and genotypes, influencing then cellulose conversion in miniaturized assay.Using a high-throughput miniaturized and semi-automated method for performing the pretreatment and saccharification steps at laboratory scale allows for the assessment of these factors on the biomass potential for producing bioethanol before moving to the industrial scale.The large genetic diversity of the perennial grass miscanthus makes it suitable for producing cellulosic ethanol in biorefineries. The saccharification potential and year variability of five genotypes belonging to Miscanthus × giganteus and Miscanthus sinensis were explored using a miniaturized and semi-automated method, allowing the application of a hot water treatment followed by an enzymatic hydrolysis. The studied genotypes highlighted distinct cellulose conversion yields due to their distinct cell wall compositions. An inter-year comparison revealed significant variations in the biomass productivity and cell wall compositions. Compared to the recalcitrant genotypes, more digestible genotypes contained higher amounts of hemicellulosic carbohydrates and lower amounts of cellulose and lignin. In contrast to hemicellulosic carbohydrates, the relationships analysis between the biomass traits and cellulose conversion clearly showed the same negative effect of cellulose and lignin on cellulose digestion. The miniaturized and semi-automated method we developed was usable at the laboratory scale and was reliable for mimicking the saccharification at the pilot scale using a steam explosion pretreatment and enzymatic hydrolysis. Therefore, this miniaturized method will allow the reliable screening of many genotypes for saccharification potential. These findings provide valuable information and tools for breeders to create genotypes combining high yield, suitable biomass composition, and high saccharification

  3. Performance Evaluation of the VIDAS® Measles IgG Assay and Its Diagnostic Value for Measuring IgG Antibody Avidity in Measles Virus Infection

    Science.gov (United States)

    Dina, Julia; Creveuil, Christian; Gouarin, Stephanie; Viron, Florent; Hebert, Amelie; Freymuth, Francois; Vabret, Astrid

    2016-01-01

    The objective of this study is primarily to compare the performance of the VIDAS® Measles immunoglobulin (Ig)G assay to that of two other serological assays using an immunoassay technique, Enzygnost® Anti-measles Virus/IgG (Siemens) and Measles IgG CAPTURE EIA® (Microimmune). The sensitivity and the agreement of the VIDAS® Measles IgG assay compared to the Enzygnost® Anti-measles Virus/IgG assay and the Measles IgG CAPTURE EIA® assay are 100%, 97.2% and 99.0%, 98.4%, respectively. The very low number of negative sera for IgG antibodies does not allow calculation of specificity. As a secondary objective, we have evaluated the ability of the VIDAS® Measles IgG assay to measure anti-measles virus IgG antibody avidity with the help of the VIDAS® CMV IgG Avidity reagent, using 76 sera from subjects with measles and 238 other sera. Different groups of populations were analyzed. In the primary infection measles group, the mean IgG avidity index was 0.16 (range of 0.07 to 0.93) compared to 0.79 (range of 0.25 to 1) in the serum group positive for IgG antibodies and negative for IgM. These data allow to define a weak anti-measles virus IgG antibody avidity as an avidity index (AI) 0.6. The VIDAS® Measles IgG assay has a performance equivalent to that of other available products. Its use, individual and quick, is well adapted to testing for anti-measles immunity in exposed subjects. PMID:27556477

  4. Effects of supplementation with green tea by-products on growth performance, meat quality, blood metabolites and immune cell proliferation in goats.

    Science.gov (United States)

    Ahmed, S T; Lee, J-W; Mun, H-S; Yang, C-J

    2015-12-01

    Forty-eight castrated male goats were used to determine the effects of feeding green tea by-products (GTB) on growth performance, meat quality, blood metabolites and immune cell proliferation. Experimental treatments consisted of basal diets supplemented with four levels of GTB (0%, 0.5%, 1.0% or 2.0%). Four replicate pens were assigned to each treatment with three goats per replicate. Increasing dietary GTB tended to linearly increase the overall average weight gain and feed intake (p = 0.09). Water holding capacity, pH and sensory attributes of meat were not affected by GTB supplementation, while cooking loss was reduced both linearly and quadratically (p goat meat were improved by GTB supplementation. Increasing dietary GTB quadratically increased protein and decreased crude fat (p goat meat. The proportions of monounsaturated fatty acid, polyunsaturated fatty acid (PUFA) and n-6 PUFA increased linearly (p meat were lower in the 2.0% GTB-supplemented group in all storage periods (p meat quality, blood metabolites and immune cell proliferation when supplemented as a feed additive in goat diet. Journal of Animal Physiology and Animal Nutrition © 2014 Blackwell Verlag GmbH.

  5. Dual Testing Algorithm of BED-CEIA and AxSYM Avidity Index Assays Performs Best in Identifying Recent HIV Infection in a Sample of Rwandan Sex Workers

    NARCIS (Netherlands)

    Braunstein, Sarah L.; Nash, Denis; Kim, Andrea A.; Ford, Ken; Mwambarangwe, Lambert; Ingabire, Chantal M.; Vyankandondera, Joseph; van de Wijgert, Janneke H. H. M.

    2011-01-01

    To assess the performance of BED-CEIA (BED) and AxSYM Avidity Index (Ax-AI) assays in estimating HIV incidence among female sex workers (FSW) in Kigali, Rwanda. Eight hundred FSW of unknown HIV status were HIV tested; HIV-positive women had BED and Ax-AI testing at baseline and ≥12 months later to

  6. Comparison of the analytical and clinical performances of Abbott RealTime High Risk HPV, Hybrid Capture 2, and DNA Chip assays in gynecology patients.

    Science.gov (United States)

    Park, Seungman; Kang, Youjin; Kim, Dong Geun; Kim, Eui-Chong; Park, Sung Sup; Seong, Moon-Woo

    2013-08-01

    The detection of high-risk (HR) HPV in cervical cancer screening is important for early diagnosis of cervical cancer or pre-cancerous lesions. We evaluated the analytical and clinical performances of 3 HR HPV assays in Gynecology patients. A total of 991 specimens were included in this study: 787 specimens for use with a Hybrid Capture 2 (HC2) and 204 specimens for a HPV DNA microarray (DNA Chip). All specimens were tested using an Abbott RealTime High Risk HPV assay (Real-time HR), PGMY PCR, and sequence analysis. Clinical sensitivities for severe abnormal cytology (severe than high-grade squamous intraepithelial lesion) were 81.8% for Real-time HR, 77.3% for HC2, and 66.7% for DNA Chip, and clinical sensitivities for severe abnormal histology (cervical intraepithelial neoplasia grade 2+) were 91.7% for HC2, 87.5% for Real-time HR, and 73.3% for DNA Chip. As compared to results of the sequence analysis, HC2, Real-time HR, and DNA Chip showed concordance rates of 94.3% (115/122), 90.0% (117/130), and 61.5% (16/26), respectively. The HC2 assay and Real-time HR assay showed comparable results to each other in both clinical and analytical performances, while the DNA Chip assay showed poor clinical and analytical performances. The Real-time HR assay can be a good alternative option for HR HPV testing with advantages of allowing full automation and simultaneous genotyping of HR types 16 and 18. Copyright © 2013 Elsevier Inc. All rights reserved.

  7. Modification of the BAX System PCR assay for detecting Salmonella in beef, produce, and soy protein isolate. Performance Tested Method 100201.

    Science.gov (United States)

    Peng, Linda X; Wallace, Morgan; Andaloro, Bridget; Fallon, Dawn; Fleck, Lois; Delduco, Dan; Tice, George

    2011-01-01

    The BAX System PCR assay for Salmonella detection in foods was previously validated as AOAC Research Institute (RI) Performance Tested Method (PTM) 100201. New studies were conducted on beef and produce using the same media and protocol currently approved for the BAX System PCR assay for E. coli O157:H7 multiplex (MP). Additionally, soy protein isolate was tested for matrix extension using the U.S. Food and Drug Administration-Bacteriological Analytical Manual (FDA-BAM) enrichment protocols. The studies compared the BAX System method to the U.S. Department of Agriculture culture method for detecting Salmonella in beef and the FDA-BAM culture method for detecting Salmonella in produce and soy protein isolate. Method comparison studies on low-level inoculates showed that the BAX System assay for Salmonella performed as well as or better than the reference method for detecting Salmonella in beef and produce in 8-24 h enrichment when the BAX System E. coli O157:H7 MP media was used, and soy protein isolate in 20 h enrichment with lactose broth followed by 3 h regrowth in brain heart infusion broth. An inclusivity panel of 104 Salmonella strains with diverse serotypes was tested by the BAX System using the proprietary BAX System media and returned all positive results. Ruggedness factors involved in the enrichment phase were also evaluated by testing outside the specified parameters, and none of the factors examined affected the performance of the assay.

  8. Ultra-performance liquid chromatography-tandem mass spectrometry-based multiplex enzyme assay for six enzymes associated with hereditary hemolytic anemia.

    Science.gov (United States)

    Park, Chul Min; Lee, Kyunghoon; Jun, Sun-Hee; Song, Sang Hoon; Song, Junghan

    2017-08-15

    Deficiencies in erythrocyte metabolic enzymes are associated with hereditary hemolytic anemia. Here, we report the development of a novel multiplex enzyme assay for six major enzymes, namely glucose-6-phosphate dehydrogenase, pyruvate kinase, pyrimidine 5'-nucleotidase, hexokinase, triosephosphate isomerase, and adenosine deaminase, deficiencies in which are implicated in erythrocyte enzymopathies. To overcome the drawbacks of traditional spectrophotometric enzyme assays, the present assay was based on ultra-performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS). The products of the six enzymes were directly measured by using ion pairing UPLC-MS/MS, and the precision, linearity, ion suppression, optimal sample amounts, and incubation times were evaluated. Eighty-three normal individuals and 13 patients with suspected enzymopathy were analyzed. The UPLC running time was within 5min. No ion suppression was observed at the retention time for the products or internal standards. We selected an optimal dilution factor and incubation time for each enzyme system. The intra- and inter-assay imprecision values (CVs) were 2.5-12.1% and 2.9-14.3%, respectively. The linearity of each system was good, with R 2 values >0.97. Patient samples showed consistently lower enzyme activities than those from normal individuals. The present ion paring UPLC-MS/MS assay enables facile and reproducible multiplex evaluation of the activity of enzymes implicated in enzymopathy-associated hemolytic anemia. Copyright © 2017 Elsevier B.V. All rights reserved.

  9. Impact of inter-genotypic recombination and probe cross-reactivity on the performance of the Abbott RealTime HCV Genotype II assay for hepatitis C genotyping.

    Science.gov (United States)

    Sridhar, Siddharth; Yip, Cyril C Y; Chan, Jasper F W; To, Kelvin K W; Cheng, Vincent C C; Yuen, Kwok-Yung

    2018-05-01

    The Abbott RealTime HCV Genotype II assay (Abbott-RT-HCV assay) is a real-time PCR based genotyping method for hepatitis C virus (HCV). This study measured the impact of inter-genotypic recombination and probe cross-reactivity on the performance of the Abbott-RT-HCV assay. 517 samples were genotyped using the Abbott-RT-HCV assay over a one-year period, 34 (6.6%) were identified as HCV genotype 1 without further subtype designation raising the possibility of inaccurate genotyping. These samples were subjected to confirmatory sequencing. 27 of these 34 (79%) samples were genotype 1b while five (15%) were genotype 6. One HCV isolate was an inter-genotypic 1a/4o recombinant. This is a novel natural HCV recombinant that has never been reported. Inter-genotypic recombination and probe cross-reactivity can affect the accuracy of the Abbott-RT-HCV assay, both of which have significant implications on antiviral regimen choice. Confirmatory sequencing of ambiguous results is crucial for accurate genotyping. Copyright © 2018 Elsevier Inc. All rights reserved.

  10. Multicenter analytical performance evaluation of a fully automated anti-Müllerian hormone assay and reference interval determination

    NARCIS (Netherlands)

    Anckaert, E.; Öktem, M.; Thies, A.; Cohen-Bacrie, M.; Daan, N. M P; Schiettecatte, J.; Müller, C.; Topcu, D.; Gröning, A.; Ternaux, F.; Engel, C.; Engelmann, S.; Milczynski, C.

    2016-01-01

    Objectives: Anti-Müllerian hormone (AMH) is an established biomarker for assessing ovarian reserve and predicting response to controlled ovarian stimulation. Its routine clinical use is hampered by the variability and low-throughput of available enzyme-linked immunosorbent assays (ELISA). The

  11. Performance Characteristics of qPCR Assays Targeting Human- and Ruminant-Associated Bacteroidetes for Microbial Source Tracking across Sixteen Countries on Six Continents

    Science.gov (United States)

    2013-01-01

    Numerous quantitative PCR assays for microbial fecal source tracking (MST) have been developed and evaluated in recent years. Widespread application has been hindered by a lack of knowledge regarding the geographical stability and hence applicability of such methods beyond the regional level. This study assessed the performance of five previously reported quantitative PCR assays targeting human-, cattle-, or ruminant-associated Bacteroidetes populations on 280 human and animal fecal samples from 16 countries across six continents. The tested cattle-associated markers were shown to be ruminant-associated. The quantitative distributions of marker concentrations in target and nontarget samples proved to be essential for the assessment of assay performance and were used to establish a new metric for quantitative source-specificity. In general, this study demonstrates that stable target populations required for marker-based MST occur around the globe. Ruminant-associated marker concentrations were strongly correlated with total intestinal Bacteroidetes populations and with each other, indicating that the detected ruminant-associated populations seem to be part of the intestinal core microbiome of ruminants worldwide. Consequently tested ruminant-targeted assays appear to be suitable quantitative MST tools beyond the regional level while the targeted human-associated populations seem to be less prevalent and stable, suggesting potential for improvements in human-targeted methods. PMID:23755882

  12. Hybrid Capture 2 and cobas human papillomavirus assays perform similarly on SurePath samples from women with abnormalities

    DEFF Research Database (Denmark)

    Fornari, D; Rebolj, M; Bjerregaard, B

    2016-01-01

    OBJECTIVE: In two laboratories (Departments of Pathology, Copenhagen University Hospitals of Herlev and Hvidovre), we compared cobas and Hybrid Capture 2 (HC2) human papillomavirus (HPV) assays using SurePath® samples from women with atypical squamous cells of undetermined significance (ASCUS......) at ≥30 years and women after treatment of cervical intraepithelial neoplasia (CIN). METHODS: Samples from 566 women with ASCUS and 411 women after treatment were routinely tested with HC2 and, thereafter, with cobas. Histological outcomes were retrieved from the Danish Pathology Data Base. We calculated...... the overall agreement between the assays, and compared their sensitivity and specificity for ≥CIN2. RESULTS: In women with ASCUS, HC2 and cobas testing results were similar in the two laboratories. The overall agreement was 91% (95% CI, 88-93). After CIN treatment, the overall agreement was 87% (95% CI, 82...

  13. Thalidomide increases human keratinocyte migration and proliferation.

    Science.gov (United States)

    Nasca, M R; O'Toole, E A; Palicharla, P; West, D P; Woodley, D T

    1999-11-01

    Thalidomide is reported to have therapeutic utility in the treatment of pyoderma gangrenosum, Behçet's disease, aphthous ulcers, and skin wounds. We investigated the effect of thalidomide on human keratinocyte proliferation and migration, two early and critical events in the re-epithelialization of skin wounds. Thalidomide at concentrations less than 1 microM did not affect keratinocyte viability. Using a thymidine incorporation assay, we found that thalidomide, at therapeutic concentrations, induced more than a 2. 5-fold increase in the proliferative potential of the cells. Keratinocyte migration was assessed by two independent motility assays: a colloidal gold assay and an in vitro scratch assay. At optimal concentrations, thalidomide increased keratinocyte migration on a collagen matrix more than 2-fold in the colloidal gold assay and more than 3-fold in the scratch assay over control. Although pro-migratory, thalidomide did not alter the level of metalloproteinase-9 secreted into culture medium. Thalidomide did, however, induce a 2-4-fold increase in keratinocyte-derived interleukin-8, a pro-migratory cellular autocrine factor. Human keratinocyte migration and proliferation are essential for re-epithelialization of skin wounds. Interleukin-8 increases human keratinocyte migration and proliferation and is chemotactic for keratinocytes. Therefore, thalidomide may modulate keratinocyte proliferation and motility by a chemokine-dependent pathway.

  14. Detection of enteropathogens associated with travelers’ diarrhea using a multiplex Luminex-based assay performed on stool samples smeared on Whatman FTA Elute cards

    Science.gov (United States)

    Lalani, Tahaniyat; Tisdale, Michele D; Maguire, Jason D; Wongsrichanalai, Chansuda; Riddle, Mark S; Tribble, David R

    2015-01-01

    We evaluated the limits of detection (LoD) for an 11-plex PCR-Luminex assay performed on Whatman FTA Elute cards smeared with stool containing pathogens associated with travelers’ diarrhea. LoDs ranged between 102-105 CFU, PFU or cysts/g for most pathogens except Cryptosporidium. Campylobacter and norovirus LoD increased with prolonged storage of cards. PMID:26072151

  15. Detection of enteropathogens associated with travelers' diarrhea using a multiplex Luminex-based assay performed on stool samples smeared on Whatman FTA Elute cards.

    Science.gov (United States)

    Lalani, Tahaniyat; Tisdale, Michele D; Maguire, Jason D; Wongsrichanalai, Chansuda; Riddle, Mark S; Tribble, David R

    2015-09-01

    We evaluated the limits of detection (LoD) for an 11-plex PCR-Luminex assay performed on Whatman(™) FTA Elute cards smeared with stool containing pathogens associated with travelers' diarrhea. LoDs ranged from 10(2) to 10(5)CFU, PFU, or cysts/g for most pathogens except Cryptosporidium. Campylobacter and norovirus LoDs increased with prolonged storage of cards. Copyright © 2015 Elsevier Inc. All rights reserved.

  16. Performance characteristics of CA 19-9 radioimmunoassay and clinical significance of serum CA 19-9 assay in patients with malignancy

    International Nuclear Information System (INIS)

    Kim, S.E.; Shong, Y.K.; Cho, B.Y.; Kim, N.K.; Koh, C.S.; Lee, M.H.; Hong, K.S.

    1985-01-01

    To evaluate the performance characteristics of CA 19-9 radioimmunoassay and the clinical significance of serum CA 19-9 assay in patients with malignancy, serum CA 19-9 levels were measured by radioimmunoassay using monoclonal antibody in 135 normal controls, 81 patients with various untreated malignancy, 9 patients of postoperative colon cancer without recurrence and 20 patients with benign gastrointestinal diseases, who visited Seoul National University Hospital from June, 1984 to March, 1985. (Author)

  17. Exogenous hydrogen sulfide promotes cell proliferation and differentiation by modulating autophagy in human keratinocytes

    International Nuclear Information System (INIS)

    Xie, Xin; Dai, Hui; Zhuang, Binyu; Chai, Li; Xie, Yanguang; Li, Yuzhen

    2016-01-01

    The effects and the underlying mechanisms of hydrogen sulfide (H 2 S) on keratinocyte proliferation and differentiation are still less known. In the current study, we investigated the effects and the underlying mechanisms of exogenous H 2 S on keratinocyte proliferation and differentiation. Human keratinocytes (HaCaT cells) were treated with various concentrations (0.05, 0.25, 0.5 and 1 mM) of sodium hydrosulfide (NaHS, a donor of H 2 S) for 24 h. A CCK-8 assay was used to assess cell viability. Western blot analysis was performed to determine the expression levels of proteins associated with differentiation and autophagy. Transmission electron microscopy was performed to observe autophagic vacuoles, and flow cytometry was applied to evaluate apoptosis. NaHS promoted the viability, induced the differentiation, and enhanced autophagic activity in a dose-dependent manner in HaCaT cells but had no effect on cell apoptosis. Blockage of autophagy by ATG5 siRNA inhibited NaHS-induced cell proliferation and differentiation. The current study demonstrated that autophagy in response to exogenous H 2 S treatment promoted keratinocyte proliferation and differentiation. Our results provide additional insights into the potential role of autophagy in keratinocyte proliferation and differentiation. - Highlights: • Exogenous H 2 S promotes keratinocyte proliferation and differentiation. • The effects of H 2 S on proliferation and differentiation is modulated by autophagy. • Exogenous H 2 S has no effect on keratinocyte apoptosis.

  18. Binding of 3H-iloprost to rat gastric mucosa: a pitfall in performing radioligand binding assays

    International Nuclear Information System (INIS)

    Beinborn, M.; Kromer, W.; Staar, U.; Sewing, K.F.

    1985-01-01

    Binding of 3 H-iloprost was studied in a 20,000 x g sediment of the rat gastric mucosa. When pH in both test tubes for total and non-specific binding was kept identical, no displaceable binding of iloprost could be detected. When no care was taken to keep the pH identical in corresponding test tubes of the binding assay, changes in pH simulated specific and displaceable binding of iloprost. Therefore it is concluded that - in contrast to earlier reports - it is not possible to demonstrate specific iloprost binding using the given method

  19. Method and apparatus for purifying nucleic acids and performing polymerase chain reaction assays using an immiscible fluid

    Energy Technology Data Exchange (ETDEWEB)

    Koh, Chung-Yan; Light, Yooli Kim; Piccini, Matthew Ernest; Singh, Anup K.

    2017-10-31

    Embodiments of the present invention are directed toward devices, systems, and methods for purifying nucleic acids to conduct polymerase chain reaction (PCR) assays. In one example, a method includes generating complexes of silica beads and nucleic acids in a lysis buffer, transporting the complexes through an immiscible fluid to remove interfering compounds from the complexes, further transporting the complexes into a density medium containing components required for PCR where the nucleic acids disassociate from the silica beads, and thermocycling the contents of the density medium to achieve PCR. Signal may be detected from labeling agents in the components required for PCR.

  20. Radiometric measurements on the fabrication of non-destructive assay standards for WIPP-Performance Demonstration Program

    International Nuclear Information System (INIS)

    Wong, A.S.; Marshall, R.S.

    1997-04-01

    The Inorganic Elemental Analysis Group of LANL has prepared several different sets of working reference materials (WRMs). These WRMs are prepared by blending quantities of nuclear materials (plutonium, americium, and enriched uranium) with diatomaceous earth. The blends are encapsulated in stainless steel cylinders. These WRMs are being measured as blind controls in neutron and gamma based non-destructive assay (NDA) instruments. Radiometric measurements on the blending homogeneity and verification on a set of sixty three plutonium based WRMs are discussed in this paper

  1. Stem cell survival is severely compromised by the thymidineanalog EdU (5-ethynyl-2'-deoxyuridine), an alternative to BrdU for proliferation assays and stem cell tracing

    DEFF Research Database (Denmark)

    Andersen, Ditte C; Skovrind, Ida; Christensen, Marlene Louise

    2013-01-01

    Stem cell therapy has opened up the possibility of treating numerous degenerating diseases. However, we are still merely at the stage of identifying appropriate sources of stem cells and exploring their full differentiation potential. Thus, tracking the stem cells upon in vivo engraftment...... and during in vitro co-culture is very important and is an area of research embracing many pitfalls. 5-Ethynyl-2'-deoxyuridine (EdU), a rather new thymidine analog incorporated into DNA, has recently been suggested to be a novel highly valid alternative to other dyes for labeling of stem cells and subsequent...... tracing of their proliferation and differentiation ability. However, our results herein do not at any stage support this recommendation, since EdU severely reduces the viability of stem cells. Accordingly, we found that transplanted EdU-labeled stem cells hardly survive upon in vivo transplantation...

  2. Performance evaluation of four type-specific commercial assays for detection of herpes simplex virus type 1 antibodies in a Middle East and North Africa population.

    Science.gov (United States)

    Aldisi, Rana S; Elsidiq, Malaz S; Dargham, Soha R; Sahara, Afifah S; Al-Absi, Enas S; Nofal, Mariam Y; Mohammed, Layla I; Abu-Raddad, Laith J; Nasrallah, Gheyath K

    2018-03-22

    The number of diagnostic assays for the detection of herpes simplex virus type 1 (HSV-1) antibodies has increased over the years. However, their performance characteristics could vary among global populations. To investigate performance of two commercial ELISA kits, HerpeSelect ® 1 ELISA and Euroimmun Anti-HSV-1 (gC1) ELISA (IgG); and two commercial immunoblot (IB)/Western blot (WB) assays, HerpeSelect ® 1 and 2 Immunoblot IgG, and Euroimmun Anti-HSV-1/HSV-2 gG2 Euroline-WB (IgG/IgM); in detecting HSV-1 antibodies in a Middle East and North Africa (MENA) population. Blood specimens were collected from blood donors in Doha, Qatar, June 2013-2016. Twenty specimens were randomly selected from 10 MENA nationalities (Egypt, Iran, Jordan, Lebanon, Pakistan, Palestine, Qatar, Sudan, Syria, and Yemen; total = 200), and tested for HSV-1 antibodies. Across all six comparisons between assays, positive percent agreement ranged between 95.7% (95% CI: 91.4-98.3%) and 100.0% (95% CI: 97.8-100.0%). Negative percent agreement ranged between 86.2% (95% CI: 68.3-96.1%) and 96.2% (95% CI: 80.4-99.9%). Overall percent agreement ranged between 95.7% (95% CI: 91.7-97.8%) and 99.4% (95% CI: 96.7-99.9%). Cohen's kappa statistic ranged between 0.84 (95% CI: 0.73-0.95) and 0.98 (95% CI: 0.93-1.00). Compared against IB/WB, HerpeSelect ® and Euroimmun had sensitivities and specificities >96% and >86%, respectively. Positive and negative predictive values were >97% and >83%, respectively. The assays showed excellent concordance with one another, and with a high kappa statistic. The ELISA kits demonstrated robust diagnostic performance compared to the IB/WB assays. These findings support the assays' utility in clinical diagnosis and research in MENA populations. Copyright © 2018 The Authors. Published by Elsevier B.V. All rights reserved.

  3. Diagnostic performance of automated liquid culture and molecular line probe assay in smear-negative pulmonary tuberculosis.

    Science.gov (United States)

    Kotwal, Aarti; Biswas, Debasis; Raghuvanshi, Shailendra; Sindhwani, Girish; Kakati, Barnali; Sharma, Shweta

    2017-04-01

    The diagnosis of smear-negative pulmonary tuberculosis (PTB) is particularly challenging, and automated liquid culture and molecular line probe assays (LPA) may prove particularly useful. The objective of our study was to evaluate the diagnostic potential of automated liquid culture (ALC) technology and commercial LPA in sputum smear-negative PTB suspects. Spot sputum samples were collected from 145 chest-symptomatic smear-negative patients and subjected to ALC, direct drug susceptibility test (DST) testing and LPA, as per manufacturers' instructions. A diagnostic yield of 26.2% was observed among sputum smear-negative TB suspects with 47.4% of the culture isolates being either INH- and/or rifampicin-resistant. Complete agreement was observed between the results of ALC assay and LPA except for two isolates which demonstrated sensitivity to INH and rifampicin at direct DST but were rifampicin-resistant in LPA. Two novel mutations were also detected among the multidrug isolates by LPA. In view of the diagnostic challenges associated with the diagnosis of TB in sputum smear-negative patients, our study demonstrates the applicability of ALC and LPA in establishing diagnostic evidence of TB.

  4. Genetic mouse embryo assay: improving performance and quality testing for assisted reproductive technology (ART) with a functional bioassay.

    Science.gov (United States)

    Gilbert, Rebecca S; Nunez, Brandy; Sakurai, Kumi; Fielder, Thomas; Ni, Hsiao-Tzu

    2016-03-24

    Growing concerns about safety of ART on human gametes, embryos, clinical outcomes and long-term health of offspring require improved methods of risk assessment to provide functionally relevant assays for quality control testing and pre-clinical studies prior to clinical implementation. The one-cell mouse embryo assay (MEA) is the most widely used for development and quality testing of human ART products; however, concerns exist due to the insensitivity/variability of this bioassay which lacks standardization and involves subjective analysis by morphology alone rather than functional analysis of the developing embryos. We hypothesized that improvements to MEA by the use of functional molecular biomarkers could enhance sensitivity and improve detection of suboptimal materials/conditions. Fresh one-cell transgenic mouse embryos with green fluorescent protein (GFP) expression driven by Pou6f1 or Cdx2 control elements were harvested and cultured to blastocysts in varied test and control conditions to compare assessment by standard morphology alone versus the added dynamic expression of GFP for screening and selection of critical raw materials and detection of suboptimal culture conditions. Transgenic mouse embryos expressing functionally relevant biomarkers of normal early embryo development can be used to monitor the developmental impact of culture conditions. This novel approach provides a superior MEA that is more meaningful and sensitive for detection of embryotoxicity than morphological assessment alone.

  5. Performance evaluation of the QIAGEN EZ1 DSP Virus Kit with Abbott RealTime HIV-1, HBV and HCV assays.

    Science.gov (United States)

    Schneider, George J; Kuper, Kevin G; Abravaya, Klara; Mullen, Carolyn R; Schmidt, Marion; Bunse-Grassmann, Astrid; Sprenger-Haussels, Markus

    2009-04-01

    Automated sample preparation systems must meet the demands of routine diagnostics laboratories with regard to performance characteristics and compatibility with downstream assays. In this study, the performance of QIAGEN EZ1 DSP Virus Kit on the BioRobot EZ1 DSP was evaluated in combination with the Abbott RealTime HIV-1, HCV, and HBV assays, followed by thermalcycling and detection on the Abbott m2000rt platform. The following performance characteristics were evaluated: linear range and precision, sensitivity, cross-contamination, effects of interfering substances and correlation. Linearity was observed within the tested ranges (for HIV-1: 2.0-6.0 log copies/ml, HCV: 1.3-6.9 log IU/ml, HBV: 1.6-7.6 log copies/ml). Excellent precision was obtained (inter-assay standard deviation for HIV-1: 0.06-0.17 log copies/ml (>2.17 log copies/ml), HCV: 0.05-0.11 log IU/ml (>2.09 log IU/ml), HBV: 0.03-0.07 log copies/ml (>2.55 log copies/ml)), with good sensitivity (95% hit rates for HIV-1: 50 copies/ml, HCV: 12.5 IU/ml, HBV: 10 IU/ml). No cross-contamination was observed, as well as no negative impact of elevated levels of various interfering substances. In addition, HCV and HBV viral load measurements after BioRobot EZ1 DSP extraction correlated well with those obtained after Abbott m2000sp extraction. This evaluation demonstrates that the QIAGEN EZ1 DSP Virus Kit provides an attractive solution for fully automated, low throughput sample preparation for use with the Abbott RealTime HIV-1, HCV, and HBV assays.

  6. The impact of HIV infection and CD4 cell count on the performance of an interferon gamma release assay in patients with pulmonary tuberculosis

    DEFF Research Database (Denmark)

    Aabye, Martine G.; Ravn, Pernille; PrayGod, George

    2009-01-01

    pulmonary tuberculosis (PTB) in a TB- and HIV-endemic population and the effect of HIV-infection and CD4 cell count on test performance. METHODOLOGY/PRINCIPAL FINDINGS: 161 patients with sputum culture confirmed PTB were subjected to HIV- and QFT-IT testing and measurement of CD4 cell count. The QFT......BACKGROUND: The performance of the tuberculosis specific Interferon Gamma Release Assays (IGRAs) has not been sufficiently documented in tuberculosis- and HIV-endemic settings. This study evaluated the sensitivity of the QuantiFERON TB-Gold In-Tube (QFT-IT) in patients with culture confirmed...

  7. The effects of CD147 on the cell proliferation, apoptosis, invasion, and angiogenesis in glioma.

    Science.gov (United States)

    Yin, Haoyuan; Shao, Ying; Chen, Xuan

    2017-01-01

    To analyze the effects of extracellular matrix metalloproteinase inducer (CD147) on glioma proliferation, apoptosis, invasion, and angiogenesis. Tissue samples were obtained from 101 glioma cases while normal brain tissues were obtained from 30 brain injury cases. Immunohistochemical assay was performed to detect the expressions of CD147, CD34, and VEGF in tissue samples. QRT-PCR was performed to detect the relative expression of CD147 mRNA in human glioma cell lines. CD147 siRNA was transfected into glioma cell line U251. Cell proliferation, apoptosis, invasion, and angiogenesis were tested by MTT, flow cytometry, Transwell assay, and vasculogenic mimicry assay, respectively. Expressions of relative proteins were analyzed with western blot. CD147 was positively expressed with the percentage of 0, 37.5, 44.8, 67.9, and 85.7 % in normal tissues and glioma tissues with WHO grades I-IV, respectively, and the scores of MVDand VEGF were associated with the expression of CD147. CD147 was significantly upregulated in the human glioma cell lines (P CD147 suppressed cell proliferation, blocked cell cycle, induced apoptosis, inhibited cell invasion and angiogenesis in glioma cells in vitro. The expression of CD147 was significantly associated with WHO tumor grade and angiogenesis; silencing of CD147 contributed to inhibition of glioma proliferation, invasion, and angiogenesis. Our study provided firm evidence that CD 147 is a potential glioma target for anti-angiogenic therapies.

  8. High performance of a new PCR-based urine assay for HPV-DNA detection and genotyping.

    Science.gov (United States)

    Tanzi, Elisabetta; Bianchi, Silvia; Fasolo, Maria Michela; Frati, Elena R; Mazza, Francesca; Martinelli, Marianna; Colzani, Daniela; Beretta, Rosangela; Zappa, Alessandra; Orlando, Giovanna

    2013-01-01

    Human papillomavirus (HPV) testing has been proposed as a means of replacing or supporting conventional cervical screening (Pap test). However, both methods require the collection of cervical samples. Urine sample is easier and more acceptable to collect and could be helpful in facilitating cervical cancer screening. The aim of this study was to evaluate the sensitivity and specificity of urine testing compared to conventional cervical smear testing using a PCR-based method with a new, designed specifically primer set. Paired cervical and first voided urine samples collected from 107 women infected with HIV were subjected to HPV-DNA detection and genotyping using a PCR-based assay and a restriction fragment length polymorphism method. Sensitivity, specificity, Positive Predictive Value (PPV), and Negative Predictive Value (NPV) were calculated using the McNemar's test for differences. Concordance between tests was assessed using the Cohen's unweighted Kappa (k). HPV DNA was detected in 64.5% (95% CI: 55.1-73.1%) of both cytobrush and urine samples. High concordance rates of HPV-DNA detection (k = 0.96; 95% CI: 0.90-1.0) and of high risk-clade and low-risk genotyping in paired samples (k = 0.80; 95% CI: 0.67-0.92 and k = 0.74; 95% CI: 0.60-0.88, respectively) were observed. HPV-DNA detection in urine versus cervix testing revealed a sensitivity of 98.6% (95% CI: 93.1-99.9%) and a specificity of 97.4% (95% CI: 87.7-99.9%), with a very high NPV (97.4%; 95% CI: 87.7-99.9%). The PCR-based assay utilized in this study proved highly sensitive and specific for HPV-DNA detection and genotyping in urine samples. These data suggest that a urine-based assay would be a suitable and effective tool for epidemiological surveillance and, most of all, screening programs. Copyright © 2012 Wiley Periodicals, Inc.

  9. Analysis of performance of a PCR-based assay to detect DNA of Aspergillus fumigatus in whole blood and serum: a comparative study with clinical samples.

    Science.gov (United States)

    Bernal-Martínez, Leticia; Gago, Sara; Buitrago, María J; Gomez-Lopez, Alicia; Rodríguez-Tudela, Juan L; Cuenca-Estrella, Manuel

    2011-10-01

    The performance of a real-time PCR-based assay was retrospectively analyzed (according to European Organization for Research and Treatment of Cancer/Mycosis Study Group criteria) in the samples of patients with invasive aspergillosis. A total of 711 serial samples (356 whole-blood and 355 serum samples) from 38 adult patients were analyzed. The Aspergillus fumigatus PCR assay results were positive for 89 of 356 (25%) whole-blood samples and 90 of 355 (25.35%) serum samples. Positive PCR results were seen in 29 of 31 (93.5%) patients for which serum was analyzed and in 31 of 33 (93.9%) cases with whole-blood specimens. Both blood and serum samples were available in 26 cases, and significant differences were not observed in this subgroup of cases. The average number of threshold cycles (C(T)) for positive blood samples was 37.6, and the average C(T) for serum was 37.4. The DNA concentration ranged between 2 and 50 fg per μl of sample, with average DNA concentrations of 10.2 and 11.7 fg in positive blood and serum samples, respectively (P > 0.01). The performance of this PCR-based quantitative assay was similar for both serum and blood samples. We recommend serum samples as the most convenient hematological sample to use for Aspergillus DNA quantification when serial determinations are done.

  10. Lysophosphatidic acid (LPA) effects on endometrial carcinoma in vitro proliferation, invasion, and matrix metalloproteinase activity.

    Science.gov (United States)

    Wang, Feng-qiang; Ariztia, Edgardo V; Boyd, Leslie R; Horton, Faith R; Smicun, Yoel; Hetherington, Jessica A; Smith, Phillip J; Fishman, David A

    2010-04-01

    Lysophosphatidic acid (LPA) has potent growth-regulatory effect in many cell types and has been linked to the in vivo tumor growth and metastasis in several malignancies. The goal of this study was to assess the regulation of (EC) microenvironment by LPA through the examination of its effect on cell proliferation, migration, invasion, uPA activity, and matrix metalloproteinase (MMP) secretion/activation. All experiments were performed in vitro using an EC cell line, HEC-1A. Cell proliferation was determined using the Promega MTS proliferation assay following 48 h of exposures to different concentrations of LPA (0.1, 1.0 and 10.0 microM). Cell invasion was assessed using a modified Boyden chamber assay with collagen I coated on the membrane. HEC-1A motility was examined by Boyden chamber migration assay as well as the scratch wound closure assay on type I collagen. MMP secretion/activation in HEC-1A conditioned medium was detected by gelatin zymography. MMP-7 mRNA expression was determined using real-time PCR. uPA activity was measured using a coupled colorimetric assay. LPA, at the concentrations of 0.1 and 1.0 microM, significantly induced the proliferation of HEC-1A cells (p0.05). Gelatin zymogram showed that HEC-1A cells secreted high levels of MMP-7, while MMP-2 and MMP-9 are barely detectable. In addition, LPA significantly enhanced uPA activity in HEC-1A conditioned medium in a concentration-dependent manner. LPA is a potent modulator of cellular proliferation and invasion for EC cells. It also has the capacity to stimulate the secretion/activity of uPA and MMP-7. Those results suggest that LPA is a bioactive modulator of EC microenvironment and may have a distinct regulation mechanism as observed in epithelial ovarian cancer. Copyright 2009. Published by Elsevier Inc.

  11. Evaluation of the performance of two tuberculosis interferon gamma release assays (IGRA-ELISA and T-SPOT.TB) for diagnosing Mycobacterium tuberculosis infection.

    Science.gov (United States)

    Wang, Linchuan; Tian, Xu-Dong; Yu, Yan; Chen, Wei

    2018-04-01

    The IGRA-ELISA and T-SPOT.TB are widely used in China. The aim of the study was to evaluate the performance of the two assays in diagnosis Mycobacterium tuberculosis infection. Of the 3727 patients in the study, 204 underwent testing using both the T-SPOT.TB and IGRA-ELISA, 1794 were tested using the T-SPOT.TB only, and 1729 were tested using the IGRA-ELISA only. The positive rate and consistency of the two assays were analyzed, and their sensitivity and specificity for diagnosing active tuberculosis were compared. There were no significant differences in the positive rate between the T-SPOT.TB test (25.8%) and IGRA-ELISA (28.6%), p = .065. The two assays were highly consistent, with a kappa value of 0.852 (p SPOT.TB test were 82.9% (107/129) and 78.6% (1309/1665), respectively, and those of IGRA-ELISA were 81.7% (94/115) and 75.2% (1214/1614), respectively. There were no significant differences in sensitivity (p > .05), but the specificity of the T-SPOT.TB test was slightly higher than that of IGRA-ELISA (p = .023). Both in terms of diagnosing M. tuberculosis infection and ruling out active tuberculosis, the performance of the IGRA-ELISA-a simple, almost labor-free assay that allows simultaneous processing of a very large number of samples-was well-matched with that of T-SPOT.TB test. However, IGRAs cannot be used as the only test to diagnose active tuberculosis. Copyright © 2018 Elsevier B.V. All rights reserved.

  12. Cell-based cytotoxicity assays for engineered nanomaterials safety screening: exposure of adipose derived stromal cells to titanium dioxide nanoparticles.

    Science.gov (United States)

    Xu, Yan; Hadjiargyrou, M; Rafailovich, Miriam; Mironava, Tatsiana

    2017-07-11

    Increasing production of nanomaterials requires fast and proper assessment of its potential toxicity. Therefore, there is a need to develop new assays that can be performed in vitro, be cost effective, and allow faster screening of engineered nanomaterials (ENMs). Herein, we report that titanium dioxide (TiO 2 ) nanoparticles (NPs) can induce damage to adipose derived stromal cells (ADSCs) at concentrations which are rated as safe by standard assays such as measuring proliferation, reactive oxygen species (ROS), and lactate dehydrogenase (LDH) levels. Specifically, we demonstrated that low concentrations of TiO 2 NPs, at which cellular LDH, ROS, or proliferation profiles were not affected, induced changes in the ADSCs secretory function and differentiation capability. These two functions are essential for ADSCs in wound healing, energy expenditure, and metabolism with serious health implications in vivo. We demonstrated that cytotoxicity assays based on specialized cell functions exhibit greater sensitivity and reveal damage induced by ENMs that was not otherwise detected by traditional ROS, LDH, and proliferation assays. For proper toxicological assessment of ENMs standard ROS, LDH, and proliferation assays should be combined with assays that investigate cellular functions relevant to the specific cell type.

  13. In Vivo Alkaline Comet Assay and Enzyme-modified Alkaline Comet Assay for Measuring DNA Strand Breaks and Oxidative DNA Damage in Rat Liver.

    Science.gov (United States)

    Ding, Wei; Bishop, Michelle E; Lyn-Cook, Lascelles E; Davis, Kelly J; Manjanatha, Mugimane G

    2016-05-04

    Unrepaired DNA damage can lead to genetic instability, which in turn may enhance cancer development. Therefore, identifying potential DNA damaging agents is important for protecting public health. The in vivo alkaline comet assay, which detects DNA damage as strand breaks, is especially relevant for assessing the genotoxic hazards of xenobiotics, as its responses reflect the in vivo absorption, tissue distribution, metabolism and excretion (ADME) of chemicals, as well as DNA repair process. Compared to other in vivo DNA damage assays, the assay is rapid, sensitive, visual and inexpensive, and, by converting oxidative DNA damage into strand breaks using specific repair enzymes, the assay can measure oxidative DNA damage in an efficient and relatively artifact-free manner. Measurement of DNA damage with the comet assay can be performed using both acute and subchronic toxicology study designs, and by integrating the comet assay with other toxicological assessments, the assay addresses animal welfare requirements by making maximum use of animal resources. Another major advantage of the assays is that they only require a small amount of cells, and the cells do not have to be derived from proliferating cell populations. The assays also can be performed with a variety of human samples obtained from clinically or occupationally exposed individuals.

  14. Validation of Performance of the Gen-Probe Human Immunodeficiency Virus Type 1 Viral Load Assay with Genital Swabs and Breast Milk Samples

    Science.gov (United States)

    DeVange Panteleeff, Dana; Emery, Sandra; Richardson, Barbra A.; Rousseau, Christine; Benki, Sarah; Bodrug, Sharon; Kreiss, Joan K.; Overbaugh, Julie

    2002-01-01

    Human immunodeficiency type 1 (HIV-1) continues to spread at an alarming rate. The virus may be transmitted through blood, genital secretions, and breast milk, and higher levels of systemic virus in the index case, as measured by plasma RNA viral load, have been shown to correlate with increased risk of transmitting HIV-1 both vertically and sexually. Less is known about the correlation between transmission and HIV-1 levels in breast milk or genital secretions, in part because reliable quantitative assays to detect HIV-1 in these fluids are not available. Here we show that the Gen-Probe HIV-1 viral load assay can be used to accurately quantify viral load in expressed breast milk and in cervical and vaginal samples collected on swabs. Virus could be quantified from breast milk and swab samples spiked with known amounts of virus, including HIV-1 subtypes A, C, and D. As few as 10 copies of HIV-1 RNA could be detected above background threshold levels in ≥77% of assays performed with spiked breast milk supernatants and mock swabs. In genital swab samples from HIV-1-infected women, similar levels of HIV-1 RNA were consistently detected in duplicate swabs taken from the same woman on the same clinic visit, suggesting that the RNA values from a single swab sample can be used to measure genital viral load. PMID:12409354

  15. Use of activity-based probes to develop high throughput screening assays that can be performed in complex cell extracts.

    Directory of Open Access Journals (Sweden)

    Edgar Deu

    2010-08-01

    Full Text Available High throughput screening (HTS is one of the primary tools used to identify novel enzyme inhibitors. However, its applicability is generally restricted to targets that can either be expressed recombinantly or purified in large quantities.Here, we described a method to use activity-based probes (ABPs to identify substrates that are sufficiently selective to allow HTS in complex biological samples. Because ABPs label their target enzymes through the formation of a permanent covalent bond, we can correlate labeling of target enzymes in a complex mixture with inhibition of turnover of a substrate in that same mixture. Thus, substrate specificity can be determined and substrates with sufficiently high selectivity for HTS can be identified. In this study, we demonstrate this method by using an ABP for dipeptidyl aminopeptidases to identify (Pro-Arg2-Rhodamine as a specific substrate for DPAP1 in Plasmodium falciparum lysates and Cathepsin C in rat liver extracts. We then used this substrate to develop highly sensitive HTS assays (Z'>0.8 that are suitable for use in screening large collections of small molecules (i.e >300,000 for inhibitors of these proteases. Finally, we demonstrate that it is possible to use broad-spectrum ABPs to identify target-specific substrates.We believe that this approach will have value for many enzymatic systems where access to large amounts of active enzyme is problematic.

  16. Standardization and performance evaluation of "modified" and "ultrasensitive" versions of the Abbott RealTime HIV-1 assay, adapted to quantify minimal residual viremia.

    Science.gov (United States)

    Amendola, Alessandra; Bloisi, Maria; Marsella, Patrizia; Sabatini, Rosella; Bibbò, Angela; Angeletti, Claudio; Capobianchi, Maria Rosaria

    2011-09-01

    Numerous studies investigating clinical significance of HIV-1 minimal residual viremia (MRV) suggest potential utility of assays more sensitive than those routinely used to monitor viral suppression. However currently available methods, based on different technologies, show great variation in detection limit and input plasma volume, and generally suffer from lack of standardization. In order to establish new tools suitable for routine quantification of minimal residual viremia in patients under virological suppression, some modifications were introduced into standard procedure of the Abbott RealTime HIV-1 assay leading to a "modified" and an "ultrasensitive" protocols. The following modifications were introduced: calibration curve extended towards low HIV-1 RNA concentration; 4 fold increased sample volume by concentrating starting material; reduced volume of internal control; adoption of "open-mode" software for quantification. Analytical performances were evaluated using the HIV-1 RNA Working Reagent 1 for NAT assays (NIBSC). Both tests were applied to clinical samples from virologically suppressed patients. The "modified" and the "ultrasensitive" configurations of the assay reached a limit of detection of 18.8 (95% CI: 11.1-51.0 cp/mL) and 4.8 cp/mL (95% CI: 2.6-9.1 cp/mL), respectively, with high precision and accuracy. In clinical samples from virologically suppressed patients, "modified" and "ultrasensitive" protocols allowed to detect and quantify HIV RNA in 12.7% and 46.6%, respectively, of samples resulted "not-detectable", and in 70.0% and 69.5%, respectively, of samples "detected laboratories for measuring MRV. Copyright © 2011 Elsevier B.V. All rights reserved.

  17. The diagnostic performance of a single GeneXpert MTB/RIF assay in an intensified tuberculosis case finding survey among HIV-infected prisoners in Malaysia.

    Directory of Open Access Journals (Sweden)

    Haider Abdulrazzaq Abed Al-Darraji

    Full Text Available Delays in tuberculosis (TB diagnosis, particularly in prisons, is associated with detrimental outcomes. The new GeneXpert MTB/RIF assay (Xpert offers accurate and rapid diagnosis of active TB, but its performance in improving case detection in high-transmission congregate settings has yet to be evaluated. We assessed the diagnostic accuracy of a single Xpert assay in an intensified case finding survey among HIV-infected prisoners in Malaysia.HIV-infected prisoners at a single site provided two early-morning sputum specimens to be examined using fluorescence smear microscopy, BACTEC MGIT 960 liquid culture and a single Xpert. The sensitivity, specificity, negative and positive predictive values of Xpert were calculated relative to gold-standard results using MGIT 960 liquid culture. Relevant clinical and demographic data were used to examine correlates of active TB disease.The majority of enrolled subjects with complete data (N=125 were men (90.4%, age <40 years (61.6% and had injected drugs (75.2%. Median CD4 lymphocyte count was 337 cells/µL (IQR 149-492; only 19 (15.2% were receiving antiretroviral therapy. Of 15 culture-positive TB cases, single Xpert assay accurately detected only eight previously undiagnosed TB cases, resulting in a sensitivity, specificity, positive predictive value and negative predictive value of 53.3% (95% CI 30.12-75.2%, 100% (95% CI 96.6-100%, 100% (95% CI 67.56-100% and 94.0% (95% CI 88.2-97.1%, respectively. Only 1 of 15 (6.7% active TB cases was smear-positive. The prevalence (12% of undiagnosed active pulmonary TB (15 of 125 prisoners was high and associated with longer duration of drug use (AOR 1.14, 95% CI 1.03-1.26, for each year of drug use.Single Xpert assay improved TB case detection and outperformed AFB smear microscopy, but yielded low screening sensitivity. Further examination of the impact of HIV infection on the diagnostic performance of the new assay alongside other screening methods in correctional

  18. Solid phase assays

    International Nuclear Information System (INIS)

    Reese, M.G.; Johnson, L.R.; Ransom, D.K.

    1980-01-01

    In a solid phase assay for quantitative determination of biological and other analytes, a sample such as serum is contacted with a receptor for the analyte being assayed, the receptor being supported on a solid support. No tracer for the analyte is added to the sample before contacting with the receptor; instead the tracer is contacted with the receptor after unbound analyte has been removed from the receptor. The assay can be otherwise performed in a conventional manner but can give greater sensitivity. (author)

  19. Hormone assay

    International Nuclear Information System (INIS)

    Eisentraut, A.M.

    1977-01-01

    An improved radioimmunoassay is described for measuring total triiodothyronine or total thyroxine levels in a sample of serum containing free endogenous thyroid hormone and endogenous thyroid hormone bound to thyroid hormone binding protein. The thyroid hormone is released from the protein by adding hydrochloric acid to the serum. The pH of the separated thyroid hormone and thyroid hormone binding protein is raised in the absence of a blocking agent without interference from the endogenous protein. 125 I-labelled thyroid hormone and thyroid hormone antibodies are added to the mixture, allowing the labelled and unlabelled thyroid hormone and the thyroid hormone antibody to bind competitively. This results in free thyroid hormone being separated from antibody bound thyroid hormone and thus the unknown quantity of thyroid hormone may be determined. A thyroid hormone test assay kit is described for this radioimmunoassay. It provides a 'single tube' assay which does not require blocking agents for endogenous protein interference nor an external solid phase sorption step for the separation of bound and free hormone after the competitive binding step; it also requires a minimum number of manipulative steps. Examples of the assay are given to illustrate the reproducibility, linearity and specificity of the assay. (UK)

  20. Assay system

    International Nuclear Information System (INIS)

    Patzke, J.B.; Rosenberg, B.J.

    1984-01-01

    The accuracy of assays for monitoring concentrations of basic drugs in biological fluids containing a 1 -acid glycoproteins, such as blood (serum or plasma), is improved by the addition of certain organic phosphate compounds to minimize the ''protein effect.'' Kits containing the elements of the invention are also disclosed

  1. Cyclooxygenase-2 Inhibition Enhances Proliferation of NKT Cells Derived from Patients with Laryngeal Cancer.

    Science.gov (United States)

    Klatka, Janusz; Grywalska, Ewelina; Hymos, Anna; Guz, Małgorzata; Polberg, Krzysztof; Roliński, Jacek; Stepulak, Andrzej

    2017-08-01

    The aim of this study was to analyze whether inhibition of cyclooxygenase-2 by celecoxib and the subsequent enhancement in the proliferation of natural killer T (NKT) cells could play a role in dendritic cell (DC)-based laryngeal cancer (LC) immunotherapy. Peripheral blood mononuclear cells were obtained from 48 male patients diagnosed with LC and 30 control patients without cancer disease. Neoplastic cell lysate preparations were made from cancer tissues obtained after surgery and used for in vitro DCs generation. NKT cells proliferation assay was performed based on 3 H-thymidine incorporation assay. An increased proliferation of NKT cells was obtained from control patients compared to NKT cells obtained from LC patients regardless of the type of stimulation or treatment. In the patient group diagnosed with LC, COX-2 inhibition resulted in a significantly enhanced proliferation of NKT cells when stimulated with autologous DCs than NKT cells stimulated with DCs without COX-2 inhibition. These correlations were not present in the control group. Higher proliferation rate of NKT cells was also observed in non-metastatic and highly differentiated LC, which was independent of the type of stimulation or treatment. COX-2 inhibition could be regarded as immunotherapy-enhancing tool in patients with LC. Copyright© 2017, International Institute of Anticancer Research (Dr. George J. Delinasios), All rights reserved.

  2. Validated assay for the simultaneous quantification of total vincristine and actinomycin-D concentrations in human EDTA plasma and of vincristine concentrations in human plasma ultrafiltrate by high-performance liquid chromatography coupled with tandem mass spectrometry

    NARCIS (Netherlands)

    Damen, Carola W. N.; Israëls, Trijn; Caron, Huib N.; Schellens, Jan H. M.; Rosing, Hilde; Beijnen, Jos H.

    2009-01-01

    A sensitive, specific and efficient high-performance liquid chromatography/tandem mass spectrometry (HPLC/MS/MS) assay for the simultaneous determination of total vincristine and actinomycin-D concentrations in human plasma and an assay for the determination of unbound vincristine are presented.

  3. The miR-383-LDHA axis regulates cell proliferation, invasion and glycolysis in hepatocellular cancer

    Directory of Open Access Journals (Sweden)

    Zhixiong Fang

    2017-02-01

    Full Text Available Objective(s: To explore the correlation between expression patterns and functions of miR-383 and LDHA in hepatocellular cancer (HCC. Materials and Methods: We detected the expression of miR-383 and LDHA in 30 HCC tissues and their matched adjacent normal tissues using qRT-PCR. Then we performed MTT assay, foci formation assay, transwell migration assay, glucose uptake assay and lactate production assay to explore the function of miR-383 in cell proliferation, invasion and glycolysis in HCC cell lines. Luciferase reporter assay was used to explore whether LDHA was a target gene of miR-383. Western blot and qRT-PCR were used to further confirm LDHA was targeted by miR-383. Then the above functional experiments were repeated to see whether the function of LDHA could be inhibited by miR-383. Results: The results of qRT-PCR showed that miR-383 was down-regulated in HCC tissues compared with their matched adjacent normal tissues. Functional experiments showed that overexpression of miR-383 significantly suppressed cell proliferation, invasion and glycolysis. Luciferase reporter assay showed LDHA was a target gene of miR-383 and expression of LDHA was inversely correlated with that of miR-383 in HCC. Besides, increased cell proliferation, invasion and glycolysis triggered by LDHA could be inhibited by overexpression of miR-383 in HCC cell lines. Conclusion: Our study proved that miR-383 is down-regulated in HCC and acts as a tumor suppressor through targeting LDHA. Targeting the miR-383-LDHA axis might be a promising strategy in HCC treatment.

  4. Investigation of OMNIgene·SPUTUM performance in delayed tuberculosis testing by smear, culture, and Xpert MTB/RIF assays in Uganda

    Directory of Open Access Journals (Sweden)

    C.D. Kelly-Cirino

    2017-06-01

    Full Text Available OMNIgene·SPUTUM (OM-S is a sample transport reagent designed to work with all tuberculosis diagnostics while eliminating the need for cold chain. OM-S-treated sputum samples were assayed in several tests after multiday holds. Raw sputa from 100 patients underwent direct smear microscopy, were manually split and assigned to the OM-S group [OM-S added at collection (no other processing required and tested after 0- to 5-day holds at room temperature] or standard-of-care (SOC group (NaOH/N-acetyl l-cysteine decontamination, all tested on day of collection. Concentrated smear microscopy, Lowenstein Jensen (LJ culture, and mycobacteria growth indicator tube (MGIT culture were performed. For patients with negative direct smear, a second sample was split, with SOC (raw sputum and OM-S portions (sediment tested in the Xpert MTB/RIF (Xpert assay. OM-S group and SOC group results were strongly concordant on all four tests [range, 89% (MGIT–97% (Xpert]. OM-S MGIT, LJ, and Xpert tests were in statistical agreement with SOC MGIT as reference. OM-S specimens had lower culture contamination rates (3% vs. 10% LJ; 2% vs. 5% MGIT but required, on average, 5.6 additional days to become MGIT-positive. The findings suggest that samples held/transported in OM-S are compatible with smear microscopy, LJ or MGIT culture, and Xpert, and perform comparably to fresh sputum samples. Larger feasibility studies are warranted.

  5. The threat of proliferation

    International Nuclear Information System (INIS)

    Palme, Olof.

    1986-01-01

    The paper on the threat of proliferation, is a keynote speech delivered to the Colloquium on Nuclear War, Nuclear Proliferation and their Consequences, Geneva, 1985. Topics discussed in the address include: nuclear weapons, nuclear war, terrorists, Non-Proliferation Treaty, nuclear disarmament, and leadership in world affairs. (UK)

  6. Design of benign matrix drums for the non-destructive assay performance demonstration program for the National TRU Program

    International Nuclear Information System (INIS)

    Becker, G.K.

    1996-09-01

    Regulatory compliance programs associated with the Department of Energy (DOE) Waste Isolation Pilot Plant (WIPP) Transuranic (TRU) Waste Characterization Program (the Program) require the collection of waste characterization data of known quality to support repository performance assessment, permitting, and associated activities. Blind audit samples, referred to as PDP (performance demonstration program) samples, are devices used in the NDA PDP program to acquire waste NDA system performance data per defined measurement routines. As defined under the current NDA PDP Program Plan, a PDP sample consists of a DOT 17C 55-gallon PDP matrix drum configured with insertable radioactive standards, working reference materials (WRMs). The particular manner in which the matrix drum and PDP standard(s) are combined is a function of the waste NDA system performance test objectives of a given cycle. The scope of this document is confined to the design of the PDP drum radioactive standard internal support structure, the matrix type and the as installed configuration. The term benign is used to designate a matrix possessing properties which are nominally non-interfering to waste NDA measurement techniques. Measurement interference sources are technique specific but include attributes such as: high matrix density, heterogeneous matrix distributions, matrix compositions containing high moderator/high Z element concentrations, etc. To the extent practicable the matrix drum design should not unduly bias one NDA modality over another due to the manner in which the matrix drum configuration manifests itself to the measurement system. To this end the PDP matrix drum configuration and composition detailed below is driven primarily by the intent to minimize the incorporation of matrix attributes known to interfere with fundamental waste NDA modalities, i.e. neutron and gamma based techniques

  7. Performance of highly sensitive cardiac troponin T assay to detect ischaemia at PET-CT in low-risk patients with acute coronary syndrome: a prospective observational study.

    Science.gov (United States)

    Morawiec, Beata; Fournier, Stephane; Tapponnier, Maxime; Prior, John O; Monney, Pierre; Dunet, Vincent; Lauriers, Nathalie; Recordon, Frederique; Trana, Catalina; Iglesias, Juan-Fernando; Kawecki, Damian; Boulat, Olivier; Bardy, Daniel; Lamsidri, Sabine; Eeckhout, Eric; Hugli, Olivier; Muller, Olivier

    2017-07-10

    Highly sensitive troponin T (hs-TnT) assay has improved clinical decision-making for patients admitted with chest pain. However, this assay's performance in detecting myocardial ischaemia in a lowrisk population has been poorly documented. To assess hs-TnT assay's performance to detect myocardial ischaemia at positron emission tomography/CT (PET-CT) in low-risk patients admitted with chest pain. Patients admitted for chest pain with a nonconclusive ECG and negative standard cardiac troponin T results at admission and after 6 hours were prospectively enrolled. Their hs-TnT samples were at T0, T2 and T6. Physicians were blinded to hs-TnT results. All patients underwent a PET-CT at rest and during adenosine-induced stress. All patients with a positive PET-CT result underwent a coronary angiography. Forty-eight patients were included. Six had ischaemia at PET-CT. All of them had ≥1 significant stenosis at coronary angiography. Areas under the curve (95% CI) for predicting significant ischaemia at PET-CT using hs-TnT were 0.764 (0.515 to 1.000) at T0, 0.812(0.616 to 1.000) at T2 and 0.813(0.638 to 0.989) at T6. The receiver operating characteristicbased optimal cut-off value for hs-TnT at T0, T2 and T6 needed to exclude significant ischaemia at PET-CT was <4 ng/L. Using this value, sensitivity, specificity, positive and negative predictive values of hs-TnT to predict significant ischaemia were 83%/38%/16%/94% at T0, 100%/40%/19%/100% at T2 and 100%/43%/20%/100% at T6, respectively. Our findings suggest that in low-risk patients, using the hs-TnT assay with a cut-off value of 4 ng/L demonstrates excellent negative predictive value to exclude myocardial ischaemia detection at PET-CT, at the expense of weak specificity and positive predictive value. ClinicalTrials.gov Identifier: NCT01374607. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2017. All rights reserved. No commercial use is permitted unless otherwise expressly

  8. Performance of the fully automated progesterone assays on the Abbott AxSYM and the Technicon Immuno 1 Analyser compared with the radioimmunoassay progesterone MAIA

    International Nuclear Information System (INIS)

    Reinsberg, J.; Jost, E.; Van der Ven, H.

    1997-01-01

    Test performance of two automated progesterone assays available on the immunoassay analysers Abbott AxSYM and Technicon Immuno 1, respectively, was evaluated in comparison with the radioimmunoassay Progesterone MAIA. For assessment of test performance imprecision, functional sensitivity and linearity of dilution was examined. Correlation with the manual radioimmunoassay was assessed using 122 serum samples over the range 0-110 nmol/L. Imprecision studies revealed for the AxSYM Progesterone within-run CV's of 1.8-6.4% and day-to-day CV's of 3.5-9.7% (concentration range 2.3-75 nmol/L); Immuno 1 Progesterone: within-run CV's 1.0-7.3%, day-to-day CV's 2.3-7.7% (concentration range 1.2-60 nmol/L). The functional sensitivity was <1.7 nmol/L for the AxSYM Progesterone and <1.1 nmol/L for the Immuno 1 Progesterone. With the AxSYM Progesterone the mean recovery after dilution from five samples was 102% (89-107%), from one sample only 69-80% was recovered; with the Immuno 1 Progesterone the mean recovery was 95% (80-105%). Despite of a quite good overall correlation (coefficients 0.972 and 0.981) the relationship of both assays to the Progesterone MAIA significantly deviate from linearity with a considerably higher slope within the lower concentration range. The relationship between the automated assays was linear over the entire concentration range (Immuno = 1.207 * AxSYM + 1; r = 0.986). The time to first result was 20 min for the AxSYM Progesterone, 45 min for the Immuno 1 Progesterone and 90 min for the Progesterone MAIA. The evaluated progesterone assays both exhibit an excellent precision and a high degree of sensitivity. They offer a rapid and flexible method for progesterone determination which may be especially useful for the monitoring of ovarian stimulation during in-vitro fertilization. (author)

  9. Evaluation of the HOOF-Print assay for typing Brucella abortus strains isolated from cattle in the United States: results with four performance criteria

    Directory of Open Access Journals (Sweden)

    Ewalt Darla R

    2005-06-01

    Full Text Available Abstract Background A fundamental question that arises during epidemiological investigations of bacterial disease outbreaks is whether the outbreak strain is genetically related to a proposed index strain. Highly discriminating genetic markers for characterizing bacterial strains can help in clarifying the genetic relationships among strains. Under the auspices of the European Society of Clinical Microbiology and Infectious Diseases, the European Study Group for Epidemiological Markers (ESGEM established guidelines for evaluating the performance of typing systems based of a number of criteria. Recently, HOOF-Print genotype analysis, a new method for typing Brucella abortus strains based on hypervariability at eight tandem repeat loci, was described. This paper evaluates the HOOF-Print assay by four of the criteria set out by the ESGEM: typeability, reproducibility, power of discrimination, and concordance with other typing methods. Results The HOOF-Print Assay was evaluated with a test population composed of 97 unrelated field isolates and 6 common laboratory strains of B. abortus. Both typeability and reproducibility of the assay were excellent. Allele diversity and frequency varied widely among the eight loci, ranging from 1 to 13 alleles. The power of discrimination, measured by the Hunter-Gaston discrimination index (HGDI, varied by locus ranging from 0 to 0.89, where a maximal value of 1.0 indicates discrimination of all strains. The HGDI values calculated for subgroups sorted by biovar were similar to the values determined for the whole population. None of the individual loci achieved the recommended HGDI threshold of 0.95, but the HGDI of the composite profiles was 0.99 (93 unique genotypes from 97 field strains evaluated, well above the recommended threshold. By comparison, the HGDI value for biovar typing was 0.61 in a test population biased with disproportionate numbers of the less common biovars. Cluster analysis based on HOOF

  10. Analytical performance evaluation of the Elecsys® Cyclosporine and Elecsys® Tacrolimus assays on the cobas e411 analyzer

    Directory of Open Access Journals (Sweden)

    Maki Sasano

    2017-08-01

    Full Text Available Background: Cyclosporine (CsA and tacrolimus (TAC are immunosuppressant drugs that are often used to treat autoimmune diseases and as transplantation therapy; therefore, their concentrations need to be monitored carefully. We herein evaluated the analytical performance of the Elecsys® Cyclosporine and Elecsys® Tacrolimus assay kits, which have been newly developed to measure CsA and TAC concentrations in the whole blood. Methods: We used residual whole blood samples from autoimmune disease and transplantation patients who were being treated with CsA or TAC. CsA concentrations were measured using an affinity chrome-mediated immunoassay (ACMIA and an electrochemiluminescence immunoassay (ECLIA. TAC concentrations were measured using a chemiluminescence immunoassay (CLIA and ECLIA. We investigated assay precision, linearity, lower limit of quantitation (LOQ, stability of calibration, influence of interference substances and the hematocrit, correlation of ACMIA with ECLIA, and correlation of CLIA with ECLIA. Results: Within-assay coefficients of variation were 1.8−3.6% (CsA: 94−1238 ng/mL and 2.9−3.9% (TAC: 2.1−17.8 ng/mL, whereas day-to-day coefficients of variation ranged between 3.0−4.1% (CsA and 2.8−3.9% (TAC. The limits of quantitation were defined as the concentration at which the CV was approximately 10%. Each lower LOQ obtained was 16 ng/mL (CsA, and 0.95 ng/mL (TAC. CsA and TAC calibrations were stable for at least 21 days. Neither the presence of conjugated bilirubin, unconjugated bilirubin, chyle, and rheumatoid factor nor the hematocrit affected these assays. A method comparison using a standardized major axis regression analysis of ACMIA and ECLIA was r=0.995, y=0.924x −1.175, n=200 (CsA, while that of CLIA and ECLIA was r=0.994, y=1.080x −0.197, n=200 (TAC. Conclusions: The analytical performances of the Elecsys® Cyclosporine and Elecsys®Tacrolimus assays were acceptable

  11. Expression of MiR-9 promotes proliferation, migration and ...

    African Journals Online (AJOL)

    Purpose: To investigate the effect of miR-9 on the proliferation, differentiation and migration of human neural stem cells (NSCs). Methods: The expression of miR-9 was investigated by quantitative real-time polymerase chain reaction (RT-PCR). Cell proliferation was assessed by cell counting kit-8 (CCK8) assay, while cell ...

  12. Performance and diagnostic usefulness of commercially available enzyme linked immunosorbent assay and rapid kits for detection of HIV, HBV and HCV in India

    Directory of Open Access Journals (Sweden)

    Maity Susmita

    2012-11-01

    Full Text Available Abstract Background HIV, HBV and HCV pose a major public health problem throughout the world. Detection of infection markers for these agents is a major challenge for testing laboratories in a resource poor setting. As blood transfusion is an important activity saving millions of live every year, it also carries a risk of transfusion transmissible infections caused by these fatal blood borne pathogens if the quality of testing is compromised. Conventional ELISA is regarded as the mostly used screening technique but due to limitations like high cost, unavailability in many blood banks and testing sites, involvement of costly instruments, time taking nature and requirement of highly skilled personnel for interpretation, rapid tests are gaining more importance and warrants comparison of performance. Results A comparative study between these two techniques has been performed using commercially available diagnostic kits to assess their efficacy for detection of HIV, HBV and HCV infections. Rapid kits were more efficient in specificity with synthetic antigens along with high PPV than ELISA in most cases. Comparison between different ELISA kits revealed that Microlisa HIV and Hepalisa (J. Mitra & Co. Pvt. Ltd.; ERBA LISA HIV1 + 2, ERBA LISA Hepatitis B and ERBA LISA HCV (Transasia Bio-medicals Ltd. gives uniform result with good performance in terms of sensitivity, specificity, PPV, NPV and efficiency, whereas, Microlisa HCV (J. Mitra & Co. Pvt. Ltd., Microscreen HBsAg ELISA and INNOVA HCV (Span Diagnostics Ltd. did not perform well. Rapid kits were also having high degree of sensitivity and specificity (100% except in HIV Comb and HCV Comb (J. Mitra & Co. Pvt. Ltd.. The kit efficiency didn’t vary significantly among different companies and lots in all the cases except for HCV ELISA showing statistically significant variation (p  Conclusions ELISA is a good screening assay for markers of HIV, HBV and HCV infections. Rapid tests are useful for

  13. Mast cell tryptase stimulates myoblast proliferation; a mechanism relying on protease-activated receptor-2 and cyclooxygenase-2

    Directory of Open Access Journals (Sweden)

    Côté Claude H

    2011-10-01

    Full Text Available Abstract Background Mast cells contribute to tissue repair in fibrous tissues by stimulating proliferation of fibroblasts through the release of tryptase which activates protease-activated receptor-2 (PAR-2. The possibility that a tryptase/PAR-2 signaling pathway exists in skeletal muscle cell has never been investigated. The aim of this study was to evaluate whether tryptase can stimulate myoblast proliferation and determine the downstream cascade. Methods Proliferation of L6 rat skeletal myoblasts stimulated with PAR-2 agonists (tryptase, trypsin and SLIGKV was assessed. The specificity of the tryptase effect was evaluated with a specific inhibitor, APC-366. Western blot analyses were used to evaluate the expression and functionality of PAR-2 receptor and to assess the expression of COX-2. COX-2 activity was evaluated with a commercial activity assay kit and by measurement of PGF2α production. Proliferation assays were also performed in presence of different prostaglandins (PGs. Results Tryptase increased L6 myoblast proliferation by 35% above control group and this effect was completely inhibited by APC-366. We confirmed the expression of PAR-2 receptor in vivo in skeletal muscle cells and in satellite cells and in vitro in L6 cells, where PAR-2 was found to be functional. Trypsin and SLIGKV increased L6 cells proliferation by 76% and 26% above control, respectively. COX-2 activity was increased following stimulation with PAR-2 agonist but its expression remained unchanged. Inhibition of COX-2 activity by NS-398 abolished the stimulation of cell proliferation induced by tryptase and trypsin. Finally, 15-deoxy-Δ-12,14-prostaglandin J2 (15Δ-PGJ2, a product of COX-2-derived prostaglandin D2, stimulated myoblast proliferation, but not PGE2 and PGF2α. Conclusions Taken together, our data show that tryptase can stimulate myoblast proliferation and this effect is part of a signaling cascade dependent on PAR-2 activation and on the downstream

  14. Fissile material proliferation risk

    International Nuclear Information System (INIS)

    Dreicer, J.S.; Rutherford, D.A.

    1996-01-01

    The proliferation risk of a facility depends on the material attractiveness, level of safeguards, and physical protection applied to the material in conjunction with an assessment of the impact of the socioeconomic circumstances and threat environment. Proliferation risk is a complementary extension of proliferation resistance. The authors believe a better determination of nuclear proliferation can be achieved by establishing the proliferation risk for facilities that contain nuclear material. Developing a method that incorporates the socioeconomic circumstances and threat environment inherent to each country enables a global proliferation assessment. To effectively reduce the nuclear danger, a broadly based set of criteria is needed that provides the capability to relatively assess a wide range of nuclear related sites and facilities in different countries and still ensure a global decrease in proliferation risk for fissile material (plutonium and highly enriched uranium)

  15. High-performance liquid chromatographic assay for acetaminophen and phenacetin in the presence of their metabolites in biological fluids

    International Nuclear Information System (INIS)

    Pang, K.S.; Taburet, A.M.; Hinson, J.A.; Gillette, J.R.

    1979-01-01

    The authors propose a method in which tracer amounts of a radiolabeled compound are used as the internal standard for the same unlabeled compound in high-performance liquid chromatography. The approach is valuable when a response from the internal standard becomes undesirable due to the presence of interference by the metabolites. The authors tested their approach with phenacetin and its metabolites, 2-hydroxyphenacetin, N-hydroxyphenacetin, phenetidine, acetaminophen sulfate conjugate and acetaminophen glucuronide conjugate in biological fluids with the use of [ 14 C] phenacetin and [ 3 H] acetaminophen as the internal standards, and were able to quantitate both phenacetin and acetaminophen simultaneously. They also tested the alternative approach in which the unlabeled drug was used as internal standard for tracer amounts of the same radiolabeled compound, with phenacetin and acetaminophen as the internal standards for tracer amounts of [ 14 C] phenacetin and [ 3 H] acetaminophen. Again, they were able to quantiate the two tracer radiolabeled compounds simultaneously. (Auth.)

  16. MiR-155 promotes cell proliferation and inhibits apoptosis by PTEN signaling pathway in the psoriasis.

    Science.gov (United States)

    Xu, Longjiang; Leng, Hong; Shi, Xin; Ji, Jiang; Fu, Jinxiang; Leng, Hong

    2017-06-01

    MicroRNAs (miRNAs) have been demonstrated to contribute to malignant progression in psoriasis development. The purposes of the study was to evaluated the effects of miRNA-155 on cell proliferation, migration and apoptosis in psoriasis development via PTEN singaling pathway and identify its direct target protein. Quantitative real-time RT-PCR (qRT-PCR) was performed to examine the level of miR-155 in psoriasis cells, miR-155 was downregulated in a psoriasis cell line Hacat by transfected with small interfering RNA (siRNA), respectively. Cell survival was detected by the MTT assay and colony formation assay. Cell migration and invasion were measured via wound-healing assayand transwell assay. In addition, cell cycle and apoptosis about psoriasis cells was measured by flow cytometry. In this study, qRT-PCR assay showed that the expressions of miR-155 mRNA in psoriasis tissues were significantly higher than that in normal tissues. The assays about cell growth and proliferation showed that miR-155 knockdown led to a significant decrease in cell proliferation which was determined by MTT assay and colony formation assay compared to those of Lv-NC cells. Flow cytometry analysis showed that depletion of miR-155 could cause cell cycle change and the number of apoptotic cells was significantly increased in Lv-miR155 cells compared with control cells. In addition, the expression of several apoptosis-related factors were dramatically changed, such as PTEN, PIP 3 , AKT, p-AKT, Bax and Bcl-2. Our findings indicate that down-regulation of miR-155 significantly inhibits proliferation, migration, invasion and promotes apoptosis through PTEN singaling pathway in psoriasis cells. miR-155 might function as an oncogene miRNA in the progress of psoriasis. Copyright © 2017 Elsevier Masson SAS. All rights reserved.

  17. Development and validation of a chiral high-performance liquid chromatography assay for rogletimide and rogletimide-N-oxide isomers in plasma.

    Science.gov (United States)

    Etienne, M C; Oster, W; Milano, G

    1996-01-01

    The purpose of the present study was to develop and validate a stereo-specific high-performance liquid chromatography (HPLC) assay for rogletimide (Rog) and rogletimide-N-oxide (Nox) isomers in plasma. The assay was performed with a chiral cellulose-[4-methylbenzoate]ester column (Chiracel OJ). Optimal separation was achieved isocratically with a mobile phase consisting of n-hexane/anhydrous ethanol (65/35, v/v) at a flow rate of 0.9 ml/min, with the column being thermostated at +35 degrees C (UV detection at 257 nm). Under these conditions, retention times were approximately 17, 28, 31 and 76 min for R-Rog, S-Rog, R-Nox and S-Nox, respectively. S-aminoglutethimide (S-Ag) served as the internal standard (retention time 70 min). An extraction procedure from plasma samples was developed on Bond Elut RP8 500-mg cartridges; conditioning was performed with 5 ml methanol and 5 ml water, after which 1 ml plasma that had previously been spiked with 5 microM S-Ag was applied. Washing was done with 6 ml water and elution, with 4 ml methanol. After evaporation to dryness, residues were dissolved in 400 microliters anhydrous ethanol and 12-48 microliters was injected onto the HPLC system. Blank plasma from healthy donors showed the random presence of a small interference eluting at the retention time of R-Rog, precluding the accurate quantification of R-Rog concentrations below 2.5 microM. Reproducibility assays demonstrated the need to use an internal standard. Taking into account the internal standard, at 2.5 microM the intra- and inter-assay coefficients of variation were 10.5% and 21.0% for R-Rog 5.5% and 8.7% for S-Rog, 7.6% and 20.8% for R-Nox and 11.7% and 6.4% for S-Nox, respectively. The detection limit was 2.5 microM for R-Rog, 0.5 microM for S-Rog, 0.25 microM for R-Nox and 0.5 microM for S-Nox. Linearity was satisfactory at concentrations ranging from 2.5 to 10 microM for R-Rog, from 0.5 to 10 microM for S-Rog, from 0.25 to 2.5 microM for R-Nox and from 0.50 to 2

  18. A multiplexed method for kinetic measurements of apoptosis and proliferation using live-content imaging.

    Science.gov (United States)

    Artymovich, Katherine; Appledorn, Daniel M

    2015-01-01

    In vitro cell proliferation and apoptosis assays are widely used to study cancer cell biology. Commonly used methodologies are however performed at a single, user-defined endpoint. We describe a kinetic multiplex assay incorporating the CellPlayer(TM) NucLight Red reagent to measure proliferation and the CellPlayer(TM) Caspase-3/7 reagent to measure apoptosis using the two-color, live-content imaging platform, IncuCyte(TM) ZOOM. High-definition phase-contrast images provide an additional qualitative validation of cell death based on morphological characteristics. The kinetic data generated using this strategy can be used to derive informed pharmacology measurements to screen potential cancer therapeutics.

  19. Application of 3D Printing Technology in Increasing the Diagnostic Performance of Enzyme-Linked Immunosorbent Assay (ELISA for Infectious Diseases

    Directory of Open Access Journals (Sweden)

    Harpal Singh

    2015-07-01

    Full Text Available Enzyme-linked Immunosorbent Assay (ELISA-based diagnosis is the mainstay for measuring antibody response in infectious diseases and to support pathogen identification of potential use in infectious disease outbreaks and clinical care of individual patients. The development of laboratory diagnostics using readily available 3D printing technologies provides a timely opportunity for further expansion of this technology into immunodetection systems. Utilizing available 3D printing platforms, a ‘3D well’ was designed and developed to have an increased surface area compared to those of 96-well plates. The ease and rapidity of the development of the 3D well prototype provided an opportunity for its rapid validation through the diagnostic performance of ELISA in infectious disease without modifying current laboratory practices for ELISA. The improved sensitivity of the 3D well of up to 2.25-fold higher compared to the 96-well ELISA provides a potential for the expansion of this technology towards miniaturization and Lab-On-a-Chip platforms to reduce time, volume of reagents and samples needed for such assays in the laboratory diagnosis of infectious and other diseases including applications in other disciplines.

  20. Application of 3D Printing Technology in Increasing the Diagnostic Performance of Enzyme-Linked Immunosorbent Assay (ELISA) for Infectious Diseases

    Science.gov (United States)

    Singh, Harpal; Shimojima, Masayuki; Shiratori, Tomomi; An, Le Van; Sugamata, Masami; Yang, Ming

    2015-01-01

    Enzyme-linked Immunosorbent Assay (ELISA)-based diagnosis is the mainstay for measuring antibody response in infectious diseases and to support pathogen identification of potential use in infectious disease outbreaks and clinical care of individual patients. The development of laboratory diagnostics using readily available 3D printing technologies provides a timely opportunity for further expansion of this technology into immunodetection systems. Utilizing available 3D printing platforms, a ‘3D well’ was designed and developed to have an increased surface area compared to those of 96-well plates. The ease and rapidity of the development of the 3D well prototype provided an opportunity for its rapid validation through the diagnostic performance of ELISA in infectious disease without modifying current laboratory practices for ELISA. The improved sensitivity of the 3D well of up to 2.25-fold higher compared to the 96-well ELISA provides a potential for the expansion of this technology towards miniaturization and Lab-On-a-Chip platforms to reduce time, volume of reagents and samples needed for such assays in the laboratory diagnosis of infectious and other diseases including applications in other disciplines. PMID:26184194

  1. Application of 3D Printing Technology in Increasing the Diagnostic Performance of Enzyme-Linked Immunosorbent Assay (ELISA) for Infectious Diseases.

    Science.gov (United States)

    Singh, Harpal; Shimojima, Masayuki; Shiratori, Tomomi; An, Le Van; Sugamata, Masami; Yang, Ming

    2015-07-08

    Enzyme-linked Immunosorbent Assay (ELISA)-based diagnosis is the mainstay for measuring antibody response in infectious diseases and to support pathogen identification of potential use in infectious disease outbreaks and clinical care of individual patients. The development of laboratory diagnostics using readily available 3D printing technologies provides a timely opportunity for further expansion of this technology into immunodetection systems. Utilizing available 3D printing platforms, a '3D well' was designed and developed to have an increased surface area compared to those of 96-well plates. The ease and rapidity of the development of the 3D well prototype provided an opportunity for its rapid validation through the diagnostic performance of ELISA in infectious disease without modifying current laboratory practices for ELISA. The improved sensitivity of the 3D well of up to 2.25-fold higher compared to the 96-well ELISA provides a potential for the expansion of this technology towards miniaturization and Lab-On-a-Chip platforms to reduce time, volume of reagents and samples needed for such assays in the laboratory diagnosis of infectious and other diseases including applications in other disciplines.

  2. Performance Characteristics of CA 19-9 Radioimmunoassay and Clinical Significance of Serum CA 19-9 Assay in Patients with Malignancy

    International Nuclear Information System (INIS)

    Kim, Sang Eun; Shong, Young Kee; Cho, Bo Youn; Kim, Noe Kyeong; Koh, Chang Soon; Lee, Mun Ho; Hong, Seong Woon; Hong, Kee Suk

    1985-01-01

    To evaluate the performance characteristics of CA 19-9 radioimmunoassay and the clinical significance of serum CA 19-9 assay in patients with malignancy, serum. CA 19-9 levels were measured by radioimmunoassay using monoclonal antibody in 135 normal controls, 81 patients with various untreated malignancy, 9 patients of postoperative colon cancer without recurrence and 20 patients with benign gastrointestinal diseases, who visited Seoul National University Hospital from June, 1984 to March, 1985. The results were as follows; 1) The CA 19-9 radioimmunoassay was simple to perform and can be completed in one work day. And the between-assay reproducibility and the assay recovery were both excellent. 2) The mean serum CA 19-9 level in 135 normal controls was 8.4±4.2 U/mL. Normal upper limit of serum CA 19-9 was defined as 21.0 U/mL. 4 out of 135 (3.0%) normal controls showed elevated CA 19-9 levels above the normal upper limit. 3) One out of 20 (5.0%) patients with benign gastrointestinal diseases showed elevated serum CA 19-9 level above the normal upper limit. 4) In 81 patients with various untreated malignancy, 41 patients (50.6%) showed elevated serum CA 19-9 levels. 66.7% of 18 patients with colorectal cancer, 100% of 2 patients with pancreatic cancer, 100% of 3 patients with common bile duct cancer, 47.1% of 17 patients with stomach cancer, 28.6% of 28 patients with hepatoma and 60.0% of 5 gastrointestinal tract cancers showed elevated serum CA 19-9 levels. 5) The sensitivities of serum CA 19-9 related to respectability in colorectal and stomach cancer were 33.3% in resectable colorectal cancer, 83.3% in unresectable colorectal cancer, 41.7% in resectable stomach cancer, 60.0% in unresectable stomach cancer respectively. 6) The sensitivity of serum CA 19-9 in 9 patients of postoperative colorectal cancer without recurrence were 33.3% and significantly decreased compared with that of untreated colorectal cancer, 66.7% (p<0.05). 7) In Patients with colorectal cancer

  3. Technical and clinical performance of a new assay to detect squamous cell carcinoma antigen levels for the differential diagnosis of cervical, lung, and head and neck cancer.

    Science.gov (United States)

    Holdenrieder, Stefan; Molina, Rafael; Qiu, Ling; Zhi, Xiuyi; Rutz, Sandra; Engel, Christine; Kasper-Sauer, Pia; Dayyani, Farshid; Korse, Catharina M

    2018-04-01

    In squamous cell carcinoma, squamous cell carcinoma antigen levels are often elevated. This multi-center study evaluated the technical performance of a new Elecsys ® squamous cell carcinoma assay, which measures serum squamous cell carcinoma antigen 1 and 2 levels in an equimolar manner, and investigated the potential of squamous cell carcinoma antigen for differential diagnosis of cervical, lung, and head and neck squamous cell carcinoma.Assay precision and method comparison experiments were performed across three European sites. Reference ranges for reportedly healthy individuals were determined using samples from banked European and Chinese populations. Differential diagnosis experiments determined whether cervical, lung, or head and neck cancer could be differentiated from apparently healthy, benign, or other malignant cohorts using squamous cell carcinoma antigen levels alone. Squamous cell carcinoma antigen cut-off levels were calculated based on squamous cell carcinoma antigen levels at 95% specificity. Repeatability coefficients of variation across nine analyte concentrations were ≤5.3%, and intermediate precision coefficients of variation were ≤10.3%. Method comparisons showed good correlations with Architect and Kryptor systems (slopes of 1.1 and 1.5, respectively). Reference ranges for 95th percentiles for apparently healthy individuals were 2.3 ng/mL (95% confidence interval: 1.9-3.8; European cohort, n = 153) and 2.7 ng/mL (95% confidence interval: 2.2-3.3; Chinese cohort, n = 146). Strongest differential diagnosis results were observed for cervical squamous cell carcinoma: receiver operating characteristic analysis showed that squamous cell carcinoma antigen levels (2.9 ng/mL cut-off) differentiate cervical squamous cell carcinoma (n = 127) from apparently healthy females (n = 286; area under the curve: 86.2%; 95% confidence interval: 81.8-90.6; sensitivity: 61.4%; specificity: 95.6%), benign diseases (n = 187; area

  4. The relative test performance characteristics of two commercial assays for the detection of Mycobacterium tuberculosis complex in paraffin-fixed human biopsy specimens

    Directory of Open Access Journals (Sweden)

    Broukhanski George

    2008-09-01

    Full Text Available Abstract The Seeplex™ TB Detection-2 assay (Rockville, MD is a nested endpoint PCR for the Mycobacterium tuberculosis complex (MTBC targets IS6110 and MPB64 that utilizes dual priming oligonucleotide technology. When used to detect the presence of MTBC DNA in formalin-fixed paraffin-embedded tissue specimens, the sensitivity and specificity of this assay is equivalent to a labor-intensive traditional endpoint PCR assay and is more sensitive than a commercial real-time PCR assay.

  5. Determination of vitamin B6 vitamers and pyridoxic acid in plasma: development and evaluation of a high-performance liquid chromatographic assay

    DEFF Research Database (Denmark)

    Bisp, Marianne R; Bor, Mustafa Vakur; Heinsvig, Else-Marie

    2002-01-01

    buffer containing 1 g/L sodium bisulfite. The performance of the assay was evaluated by analyzing six plasma samples with interrelated concentration and two control samples (unspiked and vitamer spiked) over a 3-months period. The HPLC method was able to identify PLP, 4-PA, PM, PL, PN, and PMP from all...... other compounds in plasma in an analytical run of 46 min. The imprecisions and mean values (presented in parenthesis in nmol/L) were (unspiked and spiked sample) 9-8% (41-65) for PLP, 12-7% (18-40) for 4-PA, 67-28% (4-19) for PL, 15% (21) for PN, 10% (27) for PM, and 27% (17) for PMP. All three B6...... will be suitable for routine quantitation of PLP and 4-PA in human plasma. Udgivelsesdato: 2002-Jun-1...

  6. High-performance liquid chromatography coupled with post-column dual-bioactivity assay for simultaneous screening of xanthine oxidase inhibitors and free radical scavengers from complex mixture.

    Science.gov (United States)

    Li, D Q; Zhao, J; Li, S P

    2014-06-06

    Xanthine oxidase (XO) can catalyze hypoxanthine and xanthine to generate uric acid and reactive oxygen species (ROS), including superoxide anion radical (O₂(•-)) and hydrogen peroxide. XO inhibitors and free radical scavengers are beneficial to the treatment of gout and many related diseases. In the present study, an on-line high-performance liquid chromatography (HPLC) coupled with post-column dual-bioactivity assay was established and successfully applied to simultaneously screening of XO inhibitors and free radical scavengers from a complex mixture, Oroxylum indicum extract. The integrated system of HPLC separation, bioactivity screening and mass spectrometry identification was proved to be simple and effective for rapid and sensitive screening of individual bioactive compounds in complex mixtures. Copyright © 2014 Elsevier B.V. All rights reserved.

  7. A high-performance liquid chromatography-based radiometric assay for sucrose-phosphate synthase and other UDP-glucose requiring enzymes

    International Nuclear Information System (INIS)

    Salvucci, M.E.; Crafts-Brandner, S.J.

    1991-01-01

    A method for product analysis that eliminates a problematic step in the radiometric sucrose-phosphate synthase assay is described. The method uses chromatography on a boronate-derivatized high-performance liquid chromatography column to separate the labeled product, [14C]sucrose phosphate, from unreacted uridine 5'-diphosphate-[14C]glucose (UDP-Glc). Direct separation of these compounds eliminates the need for treatment of the reaction mixtures with alkaline phosphatase, thereby avoiding the problem of high background caused by contaminating phosphodiesterase activity in alkaline phosphatase preparations. The method presented in this paper can be applied to many UDP-Glc requiring enzymes; here the authors show its use for determining the activities of sucrose-phosphate synthase, sucrose synthase, and uridine diphosphate-glucose pyrophosphorylase in plant extracts

  8. Use of fluorescent redox indicators to evaluate cell proliferation and viability

    DEFF Research Database (Denmark)

    Rasmussen, E.S.

    1999-01-01

    The performance of two cell viability test kits based on the use of redox indicators yielding fluorescent products, the AlamarBlue assay and a resazurin-based in vitro toxicology assay kit from Sigma, was compared in the present study. Cultures of human neonatal foreskin fibroblasts were exposed...... for 168 h of continuous exposure, but showed equal levels of cytostatic effects in cultures with a low initial cell density after 72 h of exposure. Similar characteristics of the dye solutions were observed by high-performance Liquid chromatography (HPLC) separation and UV spectroscopy, and the major...... components were tentatively identified as resazurin and resorufin. The AlamarBlue assay has gained wide application as a cell viability indicator that allows continuous monitoring of cell proliferation or cytotoxicity in human and animal cells, bacteria, and fungi, but no studies with the deliberate use...

  9. Proliferation: myth or reality?

    International Nuclear Information System (INIS)

    2005-01-01

    This article analyzes the proliferation approach, its technical condition and political motivation, and the share between the myth (political deception, assumptions and extrapolations) and the reality of proliferation. Its appreciation is complicated by the irrational behaviour of some political actors and by the significant loss of the non-use taboo. The control of technologies is an important element for proliferation slowing down but an efficient and autonomous intelligence system remains indispensable. (J.S.)

  10. TGF-beta3 is expressed in taste buds and inhibits proliferation of primary cultured taste epithelial cells.

    Science.gov (United States)

    Nakamura, Shin-ichi; Kawai, Takayuki; Kamakura, Takashi; Ookura, Tetsuya

    2010-01-01

    Transforming growth factor-betas (TGF-betas), expressed in various tissues, play important roles in embryonic development and adult tissue homeostasis through their effects on cell proliferation, cell differentiation, cell death, and cell motility. However, expression of TGF-beta signaling components and their biological effect on taste epithelia has not been elucidated. We performed expression analysis of TGF-beta signaling components in taste epithelia and found that the TGF-beta3 mRNA was specifically expressed in taste buds. Type II TGF-betas receptor (TbetaR-II) mRNA was specifically expressed in the tongue epithelia including the taste epithelia. To elucidate the biological function of TGF-beta3 in taste epithelia, we performed proliferation assay with primary cultured taste epithelial cells. In the presence of TGF-beta3, percentage of BrdU-labeled cells decreased significantly, suggesting that the TGF-beta3 inhibited the proliferation of cultured taste epithelial cells through inhibiting cell-cycle entry into S phase. By quantitative reverse transcription-polymerase chain reaction assay, we found that the TGF-beta3 resulted in an increased level of expression of p15Ink4b and p21Cip1, suggesting that the TGF-beta3 inhibited the taste epithelial cell proliferation through inhibiting G1cyclin-Cdk complexes. Taken together, these results suggested that the TGF-beta3 may regulate taste epithelial cell homeostasis through controlling cell proliferation.

  11. Niclosamide suppresses hepatoma cell proliferation via the Wnt pathway

    Directory of Open Access Journals (Sweden)

    Tomizawa M

    2013-11-01

    Full Text Available Minoru Tomizawa,1 Fuminobu Shinozaki,2 Yasufumi Motoyoshi,3 Takao Sugiyama,4 Shigenori Yamamoto,5 Makoto Sueishi,4 Takanobu Yoshida6 1Department of Gastroenterology, 2Department of Radiology, 3Department of Neurology, 4Department of Rheumatology, 5Department of Pediatrics, 6Department of Internal Medicine, National Hospital Organization Shimoshizu Hospital, Yotsukaido City, Chiba, Japan Background: The Wnt pathway plays an important role in hepatocarcinogenesis. We analyzed the association of the Wnt pathway with the proliferation of hepatoma cells using Wnt3a and niclosamide, a drug used to treat tapeworm infection. Methods: We performed an MTS assay to determine whether Wnt3a stimulated proliferation of Huh-6 and Hep3B human hepatoma cell lines after 72 hours of incubation with Wnt3a in serum-free medium. The cells were subjected to hematoxylin and eosin staining and terminal deoxynucleotidyl transferase-mediated dUTP nick end labeling (TUNEL after 48 hours of incubation. RNA was isolated 48 hours after addition of Wnt3a or niclosamide, and cyclin D1 expression levels were analyzed by real-time quantitative polymerase chain reaction. The promoter activity of T-cell factor was analyzed by luciferase assay 48 hours after transfection of TOPflash. Western blot analysis was performed with antibodies against β-catenin, dishevelled 2, and cyclin D1. Results: Cell proliferation increased with Wnt3a. Niclosamide suppressed proliferation with or without Wnt3a. Hematoxylin and eosin and TUNEL staining suggested that apoptosis occurred in cells with niclosamide. Cyclin D1 was upregulated in the presence of Wnt3a and downregulated with addition of niclosamide. The promoter activity of T-cell factor increased with Wnt3a, whereas T-cell factor promoter activity decreased with niclosamide. Western blot analysis showed that Wnt3a upregulated β-catenin, dishevelled 2, and cyclin D1, while niclosamide downregulated them. Conclusion: Niclosamide is a potential

  12. Enzyme-linked immunosorbent assay and polymerase chain reaction performance using Mexican and Guatemalan discrete typing unit I strains of Trypanosoma cruzi.

    Science.gov (United States)

    Ballinas-Verdugo, Martha; Reyes, Pedro Antonio; Mejia-Dominguez, Ana; López, Ruth; Matta, Vivian; Monteón, Victor M

    2011-12-01

    Thirteen Trypanosoma cruzi isolates from different geographic regions of Mexico and Guatemala belonging to discrete typing unit (DTU) I and a reference CL-Brener (DTU VI) strain were used to perform enzyme-linked immunosorbent assay (ELISA) and polymerase chain reaction (PCR). A panel of 57 Mexican serum samples of patients with chronic chagasic cardiopathy and asymptomatic infected subjects (blood bank donors) were used in this study. DNA from the above 14 T. cruzi strains were extracted and analyzed by PCR using different sets of primers designed from minicircle and satellite T. cruzi DNA. The chronic chagasic cardiopathy serum samples were easily recognized with ELISA regardless of the source of antigenic extract used, even with the CL-Brener TcVI, but positive serum samples from blood bank donors in some cases were not recognized by some Mexican antigenic extracts. On the other hand, PCR showed an excellent performance despite the set of primers used, since all Mexican and Guatemalan T. cruzi strains were correctly amplified. In general terms, Mexican, Guatemalan, and CL-Brener T. cruzi strains are equally good sources of antigen when using the ELISA test to detect Mexican serum samples. However, there are some strains with poor performance. The DTU I strains are easily detected using either kinetoplast or satellite DNA target designed from DTU VI strains.

  13. FLUIDICS DEVICE FOR ASSAY

    DEFF Research Database (Denmark)

    2007-01-01

    The present invention relates to a device for use in performing assays on standard laboratory solid supports whereon chemical entities are attached. The invention furthermore relates to the use of such a device and a kit comprising such a device. The device according to the present invention is a...

  14. Evaluation of repeated dose micronucleus assays of the liver using N-nitrosopyrrolidine: a report of the collaborative study by CSGMT/JEMS.MMS.

    Science.gov (United States)

    Ogawa, Izumi; Hagioa, Soichiro; Furukawa, Satoshi; Abe, Masayoshi; Kuroda, Yusuke; Hayashi, Seigo; Wako, Yumi; Kawasako, Kazufumi

    2015-03-01

    The repeated dose liver micronucleus (RDLMN) assay has the potential to detect liver carcinogens, and can be integrated into a general toxicological study. To assess the performance of the assay, N-nitrosopyrrolidine (NPYR), a genotoxic hepatocarcinogen, was tested in 14- or 28-day RDLMN assays. NPYR was orally administered to rats at a daily dose of 25, 50 or 100 mg/kg. One day after the last administration, a portion of the liver was removed and hepatocyte micronucleus (MN) specimens were prepared by the new method recently established by Narumi et al. In addition, a bone marrow MN assay and a histopathological examination of the liver were conducted. The detection of Phospho-Histone H3 was performed by immunohistochemistry to evaluate the proliferation rate of hepatocytes. The results showed significant increase in the number of micronucleated hepatocytes and Phospho-Histone H3-positive cells from the lowest dose in both 14- and 28-day RDLMN assays. On the other hand, the bone marrow MN assay yielded a negative result, which was in accordance with the existing report of the bone marrow MN assay using mice. Upon histopathological examination, inflammatory lesions and hypertrophy were noted, which may explain the increase in the hepatocyte proliferation and the enhancement of MN induction by NPYR. Our findings indicate that the RDLMN assay could be a useful tool for comprehensive risk assessment of carcinogenicity by providing information on both genotoxicity and histopathology when integrated into a general repeat dosing toxicity assay.

  15. Analytical Performance of Four Polymerase Chain Reaction (PCR and Real Time PCR (qPCR Assays for the Detection of Six Leishmania Species DNA in Colombia

    Directory of Open Access Journals (Sweden)

    Cielo M. León

    2017-10-01

    Full Text Available Leishmaniasis comprises a spectrum of parasitic diseases caused by protozoans of the genus Leishmania. Molecular tools have been widely employed for the detection of Leishmania due to its high sensitivity and specificity. However, the analytical performance of molecular platforms as PCR and real time PCR (qPCR including a wide variety of molecular markers has never been evaluated. Herein, the aim was to evaluate the analytical performance of 4 PCR-based assays (designed on four different targets and applied on conventional and real-time PCR platforms. We evaluated the analytical performance of conventional PCR and real time PCR, determining exclusivity and inclusivity, Anticipated Reportable Range (ARR, limit of detection (LoD and accuracy using primers directed to kDNA, HSP70, 18S and ITS-1 targets. We observed that the kDNA was the most sensitive but does not meet the criterion of exclusivity. The HSP70 presented a higher LoD in conventional PCR and qPCR in comparison with the other markers (1 × 101 and 1 × 10-1 equivalent parasites/mL respectively and had a higher coefficient of variation in qPCR. No statistically significant differences were found between the days of the test with the four molecular markers. The present study revealed that the 18S marker presented the best performance in terms of analytical sensitivity and specificity for the qPCR in the species tested (species circulating in Colombia. Therefore, we recommend to explore the analytical and diagnostic performance in future studies using a broader number of species across America.

  16. Analytical Performance of Four Polymerase Chain Reaction (PCR) and Real Time PCR (qPCR) Assays for the Detection of Six Leishmania Species DNA in Colombia

    Science.gov (United States)

    León, Cielo M.; Muñoz, Marina; Hernández, Carolina; Ayala, Martha S.; Flórez, Carolina; Teherán, Aníbal; Cubides, Juan R.; Ramírez, Juan D.

    2017-01-01

    Leishmaniasis comprises a spectrum of parasitic diseases caused by protozoans of the genus Leishmania. Molecular tools have been widely employed for the detection of Leishmania due to its high sensitivity and specificity. However, the analytical performance of molecular platforms as PCR and real time PCR (qPCR) including a wide variety of molecular markers has never been evaluated. Herein, the aim was to evaluate the analytical performance of 4 PCR-based assays (designed on four different targets) and applied on conventional and real-time PCR platforms. We evaluated the analytical performance of conventional PCR and real time PCR, determining exclusivity and inclusivity, Anticipated Reportable Range (ARR), limit of detection (LoD) and accuracy using primers directed to kDNA, HSP70, 18S and ITS-1 targets. We observed that the kDNA was the most sensitive but does not meet the criterion of exclusivity. The HSP70 presented a higher LoD in conventional PCR and qPCR in comparison with the other markers (1 × 101 and 1 × 10-1 equivalent parasites/mL respectively) and had a higher coefficient of variation in qPCR. No statistically significant differences were found between the days of the test with the four molecular markers. The present study revealed that the 18S marker presented the best performance in terms of analytical sensitivity and specificity for the qPCR in the species tested (species circulating in Colombia). Therefore, we recommend to explore the analytical and diagnostic performance in future studies using a broader number of species across America. PMID:29046670

  17. Low level light promotes the proliferation and differentiation of bone marrow derived mesenchymal stem cells

    Science.gov (United States)

    Ahn, Jin-Chul; Rhee, Yun-Hee; Choi, Sun-Hyang; Kim, Dae Yu; Chung, Phil-Sang

    2015-03-01

    Low-level light irradiation (LLLI) reported to stimulate the proliferation or differentiation of a variety of cell types. However, very little is known about the effect of light therapy on stem cells. The aim of the present study was to evaluate the effect of LLLI on the molecular physiological change of human bone marrow derived stem cells (hBMSC) by wavelength (470, 630, 660, 740 and 850, 50mW). The laser diode was performed with different time interval (0, 7.5, 15, 30J/cm2, 50mW) on hBMSC. To determine the molecular physiological changes of cellular level of hBMSC, the clonogenic assay, ATP assay, reactive oxygen species (ROS) detection, mitochondria membrane potential (MMPΦ) staining and calcium efflux assay were assessed after irradiation. There was a difference between with and without irradiation on hBMSCs. An energy density up to 30 J/cm² improved the cell proliferation in comparison to the control group. Among these irradiated group, 630 and 660nm were significantly increased the cell proliferation. The cellular level of ATP and calcium influx was increased with energy dose-dependent in all LLLI groups. Meanwhile, ROS and MMPΦ were also increased after irradiation except 470nm. It can be concluded that LLLI using infrared light and an energy density up to 30 J/cm² has a positive stimulatory effect on the proliferation or differentiation of hBMSCs. Our results suggest that LLLI may influence to the mitochondrial membrane potential activity through ATP synthesis and increased cell metabolism which leads to cell proliferation and differentiation.

  18. Effect-directed fingerprints of 77 botanical extracts via a generic high-performance thin-layer chromatography method combined with assays and mass spectrometry.

    Science.gov (United States)

    Krüger, S; Hüsken, L; Fornasari, R; Scainelli, I; Morlock, G E

    2017-12-22

    Quantitative effect-directed profiles of 77 industrially and freshly extracted botanicals like herbs, spices, vegetables and fruits, widely used as food ingredients, dietary supplements or traditional medicine, gave relevant information on their quality. It allows the assessment of food, dietary supplements and phytomedicines with regard to potential health-promoting activities. In contrary to sum parameter assays and targeted analysis, chromatography combined with effect-directed analysis allows fast assignment of single active compounds and evaluation of their contribution to the overall activity, originating from a food or botanical sample. High-performance thin-layer chromatography was hyphenated with UV/Vis/FLD detection and effect-directed analysis, using the 2,2-diphenyl-1-picrylhydrazyl radical, Gram-negative Aliivibrio fischeri, Gram-positive Bacillus subtilis, acetylcholinesterase and tyrosinase assays. Bioactive compounds of interest were eluted using an elution head-based interface and further characterized by electrospray ionization (high-resolution) mass spectrometry. This highly streamlined workflow resulted in a hyphenated HPTLC-UV/Vis/FLD-EDA-ESI + /ESI - -(HR)MS method. The excellent quantification power of the method was shown on three compounds. For rosmarinic acid, contents ranged from 4.5mg/g (rooibos) to 32.6mg/g (rosemary), for kaempferol-3-glucoside from 0.6mg/g (caraway) to 4.4mg/g (wine leaves), and for quercetin-3-glucoside from 1.1mg/g (hawthorn leaves) to 17.7mg/g (thyme). Three mean repeatabilities (%RSD) over 18 quantifications for the three compounds were ≤2.2% and the mean intermediate precision over three different days (%RSD, n=3) was 5.2%. Copyright © 2017 Elsevier B.V. All rights reserved.

  19. Suppressive effects of 3-bromopyruvate on the proliferation and the motility of hepatocellular carcinoma cells.

    Science.gov (United States)

    Tomizawa, Minoru; Shinozaki, Fuminobu; Motoyoshi, Yasufumi; Sugiyama, Takao; Yamamoto, Shigenori; Ishige, Naoki

    2016-01-01

    The compound 3-bromopyruvate (3BP) is an analogue of pyruvate, which is the final product of glycolysis that enters the citric acid cycle. The present study aimed to investigate the suppressive effects of 3BP on the proliferation and motility of hepatocellular carcinoma (HCC) cells. HLF and PLC/PRF/5 cells were cultured with 3BP and subjected to an MTS assay. Apoptosis was analyzed by hematoxylin and eosin staining. Cell motility was analyzed using a scratch assay. Real-time quantitative polymerase chain reaction (PCR) was performed to determine the expression levels of cyclin D1 and matrix metalloproteinase (MMP)9. Proliferation of both cell lines was significantly suppressed by 3BP at 100 µM (P<0.05). The expression level of cyclin D1 was decreased after 3BP treatment at 100 µM in both cell lines (P<0.05). Pyknotic nuclei were observed in the cells cultured with 3BP at 100 µM. These results revealed that 3BP suppressed cell proliferation, decreased the expression of cyclin D1, and induced apoptosis in HCC cells. 3BP significantly suppressed motility in both cell lines (P<0.05). The expression level of MMP9 was significantly decreased (P<0.05). 3BP suppressed the proliferation and motility of HCC cells by decreasing the expression of cyclin D1 and MMP9.

  20. MicroRNA-222 Promotes the Proliferation of Pulmonary Arterial Smooth Muscle Cells by Targeting P27 and TIMP3

    Directory of Open Access Journals (Sweden)

    Ying Xu

    2017-08-01

    Full Text Available Background/Aims: Aberrant vascular smooth muscle cell (VSMC proliferation plays an important role in the development of pulmonary artery hypertension (PAH. Dysregulated microRNAs (miRNAs, miRs have been implicated in the progression of PAH. miR-222 has a pro-proliferation effect on VSMCs while it has an anti-proliferation effect on vascular endothelial cells (ECs. As the biological function of a single miRNA could be cell-type specific, the role of miR-222 in pulmonary artery smooth muscle cell (PASMC proliferation is not clear and deserves to be explored. Methods: PASMCs were transfected with miR-222 mimic or inhibitor and PASMC proliferation was determined by Western blot for PCNA, Ki-67 and EdU staining, and cell number counting. The target genes of miR-222 including P27 and TIMP3 were determined by luciferase assay and Western blot. In addition, the functional rescue experiments were performed based on miR-222 inhibitor and siRNAs to target genes. Results: miR-222 mimic promoted PASMC proliferation while miR-222 inhibitor decreased that. TIMP3 was identified to be a direct target gene of miR-222 based on luciferase assay. Meanwhile, P27 and TIMP3 were up-regulated by miR-222 inhibitor and down-regulated by miR-222 mimic. Moreover, P27 siRNA and TIMP3 siRNA could both attenuate the anti-proliferation effect of miR-222 inhibitor in PASMCs, supporting that P27 and TIMP3 are at least partially responsible for the regulatory effect of miR-222 in PASMCs. Conclusion: miR-222 promotes PASMC proliferation at least partially through targeting P27 and TIMP3.

  1. Rover waste assay system

    Energy Technology Data Exchange (ETDEWEB)

    Akers, D.W.; Stoots, C.M.; Kraft, N.C.; Marts, D.J. [Idaho National Engineering Lab., Idaho Falls, ID (United States)

    1997-11-01

    The Rover Waste Assay System (RWAS) is a nondestructive assay system designed for the rapid assay of highly-enriched {sup 235}U contaminated piping, tank sections, and debris from the Rover nuclear rocket fuel processing facility at the Idaho Chemical Processing Plant. A scanning system translates a NaI(Tl) detector/collimator system over the structural components where both relative and calibrated measurements for {sup 137}Cs are made. Uranium-235 concentrations are in operation and is sufficiently automated that most functions are performed by the computer system. These functions include system calibration, problem identification, collimator control, data analysis, and reporting. Calibration of the system was done through a combination of measurements on calibration standards and benchmarked modeling. A description of the system is presented along with the methods and uncertainties associated with the calibration and analysis of the system for components from the Rover facility. 4 refs., 2 figs., 4 tabs.

  2. Rover waste assay system

    International Nuclear Information System (INIS)

    Akers, D.W.; Stoots, C.M.; Kraft, N.C.; Marts, D.J.

    1997-01-01

    The Rover Waste Assay System (RWAS) is a nondestructive assay system designed for the rapid assay of highly-enriched 235 U contaminated piping, tank sections, and debris from the Rover nuclear rocket fuel processing facility at the Idaho Chemical Processing Plant. A scanning system translates a NaI(Tl) detector/collimator system over the structural components where both relative and calibrated measurements for 137 Cs are made. Uranium-235 concentrations are in operation and is sufficiently automated that most functions are performed by the computer system. These functions include system calibration, problem identification, collimator control, data analysis, and reporting. Calibration of the system was done through a combination of measurements on calibration standards and benchmarked modeling. A description of the system is presented along with the methods and uncertainties associated with the calibration and analysis of the system for components from the Rover facility. 4 refs., 2 figs., 4 tabs

  3. Director's series on proliferation

    International Nuclear Information System (INIS)

    Bailey, K.C.; Price, M.E.

    1995-01-01

    This is an occasional publication of essays on the topics of nuclear, chemical, biological, and missile proliferation. The views represented are those of the author's. Essay topics include: Nuclear Proliferation: Myth and Reality; Problems of Enforcing Compliance with Arms Control Agreements; The Unreliability of the Russian Officer Corps: Reluctant Domestic Warriors; and Russia's Nuclear Legacy

  4. Performance evaluation of cobas HBV real-time PCR assay on Roche cobas 4800 System in comparison with COBAS AmpliPrep/COBAS TaqMan HBV Test.

    Science.gov (United States)

    Kim, Hanah; Hur, Mina; Bae, Eunsin; Lee, Kyung-A; Lee, Woo-In

    2018-02-19

    Hepatitis B virus (HBV) nucleic acid amplification testing (NAAT) is important for the diagnosis and management of HBV infection. We evaluated the analytical performance of the cobas HBV NAAT (Roche Diagnostics GmbH, Mannheim, Germany) on the cobas 4800 System in comparison with COBAS AmpliPrep/COBAS TaqMan HBV Test (CAP/CTM HBV). Precision was evaluated using three levels of cobas HBV/HCV/HIV-1 Control Kit, and linearity was evaluated across the anticipated measuring range (10.0-1.0×109 IU/mL) at seven levels using clinical samples. Detection capability, including limit of blank (LOB), limit of detection (LOD) and limit of quantitation (LOQ), was verified using the 4th WHO International Standard for HBV DNA for NAT (NIBSC code: 10/266). Correlation between the two systems was compared using 205 clinical samples (102 sera and 103 EDTA plasma). Repeatability and total imprecision (coefficient of variation) ranged from 0.5% to 3.8% and from 0.5% to 3.5%, respectively. Linearity (coefficient of determination, R2) was 0.999. LOB, LOD and LOQ were all acceptable within the observed proportion rate (85%). Correlation was very high between the two systems in both serum and plasma samples (correlation coefficient [r]=0.995). The new cobas HBV real-time PCR assay on the cobas 4800 System showed reliable analytical performances.

  5. Assay method and compositions

    International Nuclear Information System (INIS)

    1977-01-01

    Methods are described for measuring catecholamine levels in human and animal body fluids and tissues using the catechol-O-methyl-transferase (COMT) radioassay. The assay involves incubating the biological sample with COMT and the tritiated methyl donor, S-adenosyl-L-methionine( 3 H)-methyl. The O-methylated ( 3 H) epinephrine and/or norepinephrine are extracted and oxidised to vanillin- 3 H which in turn is extracted and its radioactivity counted. When analysing dopamine levels the assay is extended by vanillin- 3 H and raising the pH of the aqueous periodate phase from which O-methylated ( 3 H) dopamine is extracted and counted. The assay may be modified depending on whether measurements of undifferentiated total endogenous catecholamine levels or differential analyses of the catecholamine levels are being performed. The sensitivity of the assay can be as low as 5 picograms for norepinephrine and epinephrine and 12 picograms for dopamine. The assemblance of the essential components of the assay into a kit for use in laboratories is also described. (U.K.)

  6. Performance and diagnostic usefulness of commercially available enzyme linked immunosorbent assay and rapid kits for detection of HIV, HBV and HCV in India.

    Science.gov (United States)

    Maity, Susmita; Nandi, Srijita; Biswas, Subrata; Sadhukhan, Salil Kumar; Saha, Malay Kumar

    2012-11-26

    HIV, HBV and HCV pose a major public health problem throughout the world. Detection of infection markers for these agents is a major challenge for testing laboratories in a resource poor setting. As blood transfusion is an important activity saving millions of live every year, it also carries a risk of transfusion transmissible infections caused by these fatal blood borne pathogens if the quality of testing is compromised. Conventional ELISA is regarded as the mostly used screening technique but due to limitations like high cost, unavailability in many blood banks and testing sites, involvement of costly instruments, time taking nature and requirement of highly skilled personnel for interpretation, rapid tests are gaining more importance and warrants comparison of performance. A comparative study between these two techniques has been performed using commercially available diagnostic kits to assess their efficacy for detection of HIV, HBV and HCV infections. Rapid kits were more efficient in specificity with synthetic antigens along with high PPV than ELISA in most cases. Comparison between different ELISA kits revealed that Microlisa HIV and Hepalisa (J. Mitra & Co. Pvt. Ltd.); ERBA LISA HIV1 + 2, ERBA LISA Hepatitis B and ERBA LISA HCV (Transasia Bio-medicals Ltd.) gives uniform result with good performance in terms of sensitivity, specificity, PPV, NPV and efficiency, whereas, Microlisa HCV (J. Mitra & Co. Pvt. Ltd.), Microscreen HBsAg ELISA and INNOVA HCV (Span Diagnostics Ltd.) did not perform well. Rapid kits were also having high degree of sensitivity and specificity (100%) except in HIV Comb and HCV Comb (J. Mitra & Co. Pvt. Ltd.). The kit efficiency didn't vary significantly among different companies and lots in all the cases except for HCV ELISA showing statistically significant variation (p bank. For availability of quality commercial diagnostic assays, evaluation of kit may be helpful.

  7. Proliferation Networks and Financing

    International Nuclear Information System (INIS)

    Gruselle, Bruno

    2007-01-01

    The objective of this study is to propose practical solutions aimed at completing and strengthening the existing arrangement for the control of nuclear proliferation through a control of financial as well as material or immaterial flows. In a first part, the author proposes a systemic analysis of networks of suppliers and demanders. He notably evokes the Khan's network and the Iraqi acquisition network during the 1993-2001 period. He also proposes a modelling of proliferation networks (supplier networks and acquisition networks) and of their interactions. In a second part, the author examines possible means and policies aimed at neutralising proliferation networks: organisation, adaptation and improvement of intelligence tools in front of proliferation networks, and means, limitations and perspectives of network neutralisation. He also briefly addresses the possibility of military action to contain proliferation flows

  8. Exogenous hydrogen sulfide promotes cell proliferation and differentiation by modulating autophagy in human keratinocytes

    Energy Technology Data Exchange (ETDEWEB)

    Xie, Xin [Department of Dermatology, The Second Affiliated Hospital of Harbin Medical University, Harbin, 150086, Heilongjiang Province (China); Dai, Hui [Department of Cardiology, The First Affiliated Hospital of Harbin Medical University, Harbin, 150001, Heilongjiang Province (China); Zhuang, Binyu [Department of Dermatology, The Second Affiliated Hospital of Harbin Medical University, Harbin, 150086, Heilongjiang Province (China); Chai, Li; Xie, Yanguang [Institute of Dermatology of Heilongjiang Province, Harbin, 150001, Heilongjiang Province (China); Li, Yuzhen, E-mail: liyuzhen@medmail.com.cn [Department of Dermatology, The Second Affiliated Hospital of Harbin Medical University, Harbin, 150086, Heilongjiang Province (China)

    2016-04-08

    The effects and the underlying mechanisms of hydrogen sulfide (H{sub 2}S) on keratinocyte proliferation and differentiation are still less known. In the current study, we investigated the effects and the underlying mechanisms of exogenous H{sub 2}S on keratinocyte proliferation and differentiation. Human keratinocytes (HaCaT cells) were treated with various concentrations (0.05, 0.25, 0.5 and 1 mM) of sodium hydrosulfide (NaHS, a donor of H{sub 2}S) for 24 h. A CCK-8 assay was used to assess cell viability. Western blot analysis was performed to determine the expression levels of proteins associated with differentiation and autophagy. Transmission electron microscopy was performed to observe autophagic vacuoles, and flow cytometry was applied to evaluate apoptosis. NaHS promoted the viability, induced the differentiation, and enhanced autophagic activity in a dose-dependent manner in HaCaT cells but had no effect on cell apoptosis. Blockage of autophagy by ATG5 siRNA inhibited NaHS-induced cell proliferation and differentiation. The current study demonstrated that autophagy in response to exogenous H{sub 2}S treatment promoted keratinocyte proliferation and differentiation. Our results provide additional insights into the potential role of autophagy in keratinocyte proliferation and differentiation. - Highlights: • Exogenous H{sub 2}S promotes keratinocyte proliferation and differentiation. • The effects of H{sub 2}S on proliferation and differentiation is modulated by autophagy. • Exogenous H{sub 2}S has no effect on keratinocyte apoptosis.

  9. Diagnostic performance of a novel loop-mediated isothermal amplification (LAMP) assay targeting the apicoplast genome for malaria diagnosis in a field setting in sub-Saharan Africa.

    Science.gov (United States)

    Oriero, Eniyou C; Okebe, Joseph; Jacobs, Jan; Van Geertruyden, Jean-Pierre; Nwakanma, Davis; D'Alessandro, Umberto

    2015-10-09

    New diagnostic tools to detect reliably and rapidly asymptomatic and low-density malaria infections are needed as their treatment could interrupt transmission. Isothermal amplification techniques are being explored for field diagnosis of malaria. In this study, a novel molecular tool (loop-mediated isothermal amplification-LAMP) targeting the apicoplast genome of Plasmodium falciparum was evaluated for the detection of asymptomatic malaria-infected individuals in a rural setting in The Gambia. A blood was collected from 341 subjects (median age 9 years, range 1-68 years) screened for malaria. On site, a rapid diagnostic test (RDT, SD Bioline Malaria Antigen P.f) was performed, thick blood films (TBF) slides for microscopy were prepared and dry blood spots (DBS) were collected on Whatman(®) 903 Specimen collection paper. The TBF and DBS were transported to the field laboratory where microscopy and LAMP testing were performed. The latter was done on DNA extracted from the DBS using a crude (methanol/heating) extraction method. A laboratory-based PCR amplification was done on all the samples using DNA extracted with the Qiagen kit and its results were taken as reference for all the other tests. Plasmodium falciparum malaria prevalence was 37 % (127/341) as detected by LAMP, 30 % (104/341) by microscopy and 37 % (126/341) by RDT. Compared to the reference PCR method, sensitivity was 92 % for LAMP, 78 % for microscopy, and 76 % for RDT; specificity was 97 % for LAMP, 99 % for microscopy, and 88 % for RDT. Area under the receiver operating characteristic (ROC) curve in comparison with the reference standard was 0.94 for LAMP, 0.88 for microscopy and 0.81 for RDT. Turn-around time for the entire LAMP assay was approximately 3 h and 30 min for an average of 27 ± 9.5 samples collected per day, compared to a minimum of 10 samples an hour per operator by RDT and over 8 h by microscopy. The LAMP assay could produce reliable results the same day of the screening. It could

  10. Assessing the performance of a Loop Mediated Isothermal Amplification (LAMP) assay for the detection and subtyping of high-risk suptypes of Human Papilloma Virus (HPV) for Oropharyngeal Squamous Cell Carcinoma (OPSCC) without DNA purification.

    Science.gov (United States)

    Rohatensky, Mitchell G; Livingstone, Devon M; Mintchev, Paul; Barnes, Heather K; Nakoneshny, Steven C; Demetrick, Douglas J; Dort, Joseph C; van Marle, Guido

    2018-02-08

    Oropharyngeal Squamous Cell Carcinoma (OPSCC) is increasing in incidence despite a decline in traditional risk factors. Human Papilloma Virus (HPV), specifically subtypes 16, 18, 31 and 35, has been implicated as the high-risk etiologic agent. HPV positive cancers have a significantly better prognosis than HPV negative cancers of comparable stage, and may benefit from different treatment regimens. Currently, HPV related carcinogenesis is established indirectly through Immunohistochemistry (IHC) staining for p16, a tumour suppressor gene, or polymerase chain reaction (PCR) that directly tests for HPV DNA in biopsied tissue. Loop mediated isothermal amplification (LAMP) is more accurate than IHC, more rapid than PCR and is significantly less costly. In previous work we showed that a subtype specific HPV LAMP assay performed similar to PCR on purified DNA. In this study we examined the performance of this LAMP assay without DNA purification. We used LAMP assays using established primers for HPV 16 and 18, and new primers for HPV 31 and 35. LAMP reaction conditions were tested on serial dilutions of plasmid HPV DNA to confirm minimum viral copy number detection thresholds. LAMP was then performed directly on different human cell line samples without DNA purification. Our LAMP assays could detect 10 5 , 10 3 , 10 4 , and 10 5 copies of plasmid DNA for HPV 16, 18, 31, and 35, respectively. All primer sets were subtype specific, with no cross-amplification. Our LAMP assays also reliably amplified subtype specific HPV DNA from samples without requiring DNA isolation and purification. The high risk OPSCC HPV subtype specific LAMP primer sets demonstrated, excellent clinically relevant, minimum copy number detection thresholds with an easy readout system. Amplification directly from samples without purification illustrated the robust nature of the assay, and the primers used. This lends further support HPV type specific LAMP assays, and these specific primer sets and assays

  11. Analytical and clinical performance of the Hologic Aptima HCV Quant Dx Assay for the quantification of HCV RNA in plasma samples

    DEFF Research Database (Denmark)

    Schønning, Kristian; Pedersen, Martin Schou; Johansen, Kim

    2017-01-01

    obtained from 13 patients undergoing treatment with DAAs. RESULTS: Deming regression of results from 187 plasma samples with HCV RNA >2 Log IU/mL indicated that the Aptima assay quantified higher than the CAPCTMv2 test for HCV RNA >4.9 Log IU/mL. The linearity of the Aptima assay was excellent across...

  12. Analytical and clinical performance characteristics of the Abbott RealTime MTB RIF/INH Resistance, an assay for the detection of rifampicin and isoniazid resistant Mycobacterium tuberculosis in pulmonary specimens.

    Science.gov (United States)

    Kostera, Joshua; Leckie, Gregor; Tang, Ning; Lampinen, John; Szostak, Magdalena; Abravaya, Klara; Wang, Hong

    2016-12-01

    Clinical management of drug-resistant tuberculosis patients continues to present significant challenges to global health. To tackle these challenges, the Abbott RealTime MTB RIF/INH Resistance assay was developed to accelerate the diagnosis of rifampicin and/or isoniazid resistant tuberculosis to within a day. This article summarizes the performance of the Abbott RealTime MTB RIF/INH Resistance assay; including reliability, analytical sensitivity, and clinical sensitivity/specificity as compared to Cepheid GeneXpert MTB/RIF version 1.0 and Hain MTBDRplus version 2.0. The limit of detection (LOD) of the Abbott RealTime MTB RIF/INH Resistance assay was determined to be 32 colony forming units/milliliter (cfu/mL) using the Mycobacterium tuberculosis (MTB) strain H37Rv cell line. For rifampicin resistance detection, the Abbott RealTime MTB RIF/INH Resistance assay demonstrated statistically equivalent clinical sensitivity and specificity as compared to Cepheid GeneXpert MTB/RIF. For isoniazid resistance detection, the assay demonstrated statistically equivalent clinical sensitivity and specificity as compared to Hain MTBDRplus. The performance data presented herein demonstrate that the Abbott RealTime MTB RIF/INH Resistance assay is a sensitive, robust, and reliable test for realtime simultaneous detection of first line anti-tuberculosis antibiotics rifampicin and isoniazid in patient specimens. Copyright © 2016 The Author. Published by Elsevier Ltd.. All rights reserved.

  13. Non-proliferation

    International Nuclear Information System (INIS)

    Manley, I.T.

    1981-01-01

    Proliferation is a problem that can only be solved when the political problems which lead countries to contemplate, the possession of nuclear weapons are solved; in the meantime it can only be managed. Non-proliferation policy has to deal both with the political and the technical aspects of proliferation. It must seek to buy time by addressing the reasons why nations feel the political need to construct nuclear weapons, as well as delaying the moment when such nations feel capable of doing so. The subject is examined and proposals made. (author)

  14. Getting serious about proliferation

    International Nuclear Information System (INIS)

    Leventhal, P.

    1984-01-01

    The US needs to give a higher priority to nuclear non-proliferation, but Reagan's policies assume that proliferation is inevitable and that it is more important to be a reliable supplier than to cause trade frictions by trading only with those nations which sign the non-proliferation treaty (NPT). This undercuts US leadership and the intent of the agreement. Several bills now before Congress could help to restore US leadership by tightening export restrictions and the use of plutonium from the US

  15. Clonogenic assay: adherent cells.

    Science.gov (United States)

    Rafehi, Haloom; Orlowski, Christian; Georgiadis, George T; Ververis, Katherine; El-Osta, Assam; Karagiannis, Tom C

    2011-03-13

    The clonogenic (or colony forming) assay has been established for more than 50 years; the original paper describing the technique was published in 1956. Apart from documenting the method, the initial landmark study generated the first radiation-dose response curve for X-ray irradiated mammalian (HeLa) cells in culture. Basically, the clonogenic assay enables an assessment of the differences in reproductive viability (capacity of cells to produce progeny; i.e. a single cell to form a colony of 50 or more cells) between control untreated cells and cells that have undergone various treatments such as exposure to ionising radiation, various chemical compounds (e.g. cytotoxic agents) or in other cases genetic manipulation. The assay has become the most widely accepted technique in radiation biology and has been widely used for evaluating the radiation sensitivity of different cell lines. Further, the clonogenic assay is commonly used for monitoring the efficacy of radiation modifying compounds and for determining the effects of cytotoxic agents and other anti-cancer therapeutics on colony forming ability, in different cell lines. A typical clonogenic survival experiment using adherent cells lines involves three distinct components, 1) treatment of the cell monolayer in tissue culture flasks, 2) preparation of single cell suspensions and plating an appropriate number of cells in petri dishes and 3) fixing and staining colonies following a relevant incubation period, which could range from 1-3 weeks, depending on the cell line. Here we demonstrate the general procedure for performing the clonogenic assay with adherent cell lines with the use of an immortalized human keratinocyte cell line (FEP-1811). Also, our aims are to describe common features of clonogenic assays including calculation of the plating efficiency and survival fractions after exposure of cells to radiation, and to exemplify modification of radiation-response with the use of a natural antioxidant

  16. Quantification of imatinib in human serum: validation of a high-performance liquid chromatography-mass spectrometry method for therapeutic drug monitoring and pharmacokinetic assays.

    Science.gov (United States)

    Rezende, Vinicius Marcondes; Rivellis, Ariane; Novaes, Mafalda Megumi Yoshinaga; de Alencar Fisher Chamone, Dalton; Bendit, Israel

    2013-01-01

    Imatinib mesylate has been a breakthrough treatment for chronic myeloid leukemia. It has become the ideal tyrosine kinase inhibitor and the standard treatment for chronic-phase leukemia. Striking results have recently been reported, but intolerance to imatinib and noncompliance with treatment remain to be solved. Molecular monitoring by quantitative real-time polymerase chain reaction is the gold standard for monitoring patients, and imatinib blood levels have also become an important tool for monitoring. A fast and cheap method was developed and validated using high-performance liquid chromatography-mass spectrometry for quantification of imatinib in human serum and tamsulosin as the internal standard. Remarkable advantages of the method includes use of serum instead of plasma, less time spent on processing and analysis, simpler procedures, and requiring reduced amounts of biological material, solvents, and reagents. Stability of the analyte was also studied. This research also intended to drive the validation scheme in clinical centers. The method was validated according to the requirements of the US Food and Drug Administration and Brazilian National Health Surveillance Agency within the range of 0.500-10.0 μg/mL with a limit of detection of 0.155 μg/mL. Stability data for the analyte are also presented. Given that the validated method has proved to be linear, accurate, precise, and robust, it is suitable for pharmacokinetic assays, such as bioavailability and bioequivalence, and is being successfully applied in routine therapeutic drug monitoring in the hospital service.

  17. High-performance liquid chromatography assay using ultraviolet detection for urinary quantification of milrinone concentrations in cardiac surgery patients undergoing cardiopulmonary bypass.

    Science.gov (United States)

    Gavra, Paul; Nguyen, Anne Q N; Beauregard, Natasha; Denault, André Y; Varin, France

    2014-08-01

    An analytical assay using liquid-liquid extraction and high-performance liquid chromatography with ultraviolet detection was developed for the quantification of total (conjugated and unconjugated) urinary concentrations of milrinone after the inhalation of a 5 mg dose in 15 cardiac patients undergoing cardiopulmonary bypass. Urine samples (700 μL) were extracted with ethyl-acetate and subsequently underwent acid back-extraction before and after deconjugation by mild acid hydrolysis. Milrinone was separated on a strong cation exchange analytical column. The mobile phase consisted of a constant mixture of acetonitrile:tetrahydrofurane-NaH2 PO4 buffer (40:60 v/v, pH 3.0). Thirteen calibration curves were linear in the concentration range of 31.25-4000 ng/mL, using olprinone as the internal standard (r(2) range 0.9911-0.9999, n = 13). Mean milrinone recovery and accuracy were respectively 85.2 ± 3.1% and ≥93%. Intra- and inter-day precisions (coefficients of variation) were ≤5% and ≤8%, respectively. Over a 24 h collection period, the cumulative urinary milrinone recovered from 15 patients was 26.1 ± 7.7% of the nominal 5 mg dose administered. The relative amount of milrinone glucuronic acid conjugate was negligible in the urine of patients undergoing cardiopulmonary bypass This method proved to be reliable, specific and accurate to determine the cumulative amount of total milrinone recovered in urine after inhalation. Copyright © 2014 John Wiley & Sons, Ltd.

  18. Assay of common sunscreen agents in suncare products by high-performance liquid chromatography on a cyanopropyl-bonded silica column.

    Science.gov (United States)

    Simeoni, Silvia; Tursilli, Rosanna; Bianchi, Anna; Scalia, Santo

    2005-06-15

    A rapid high-performance liquid chromatographic method was developed for the simultaneous assay of eight of the most common sunscreen agents (octyl-methoxycinnamate, oxybenzone, butyl-methoxydibenzoylmethane, octyl-salicilate, methylbenzylidene camphor, octyl-dimethylamminobenzoate, phenylbenzimidazole sulphonic acid and octocrylene) in sun protection products. Evaluation of the influence of different stationary phases and eluents on the separation selectivity showed that optimal resolution was obtained on a cyanopropyl-silica column eluted with methanol-acetonitrile-tetrahydrofuran-aqueous acetic acid. A small adjustment of the proposed chromatographic system (reduction in the aqueous content of the mobile phase) permitted also the determination of the extremely hydrophobic UV filter, methylene bis-benzotriazolyl tetramethylbutylphenol along with three other sunscreen agents, octyl-methoxycinnamate, oxybenzone, butyl-methoxydibenzoylmethane. Recoveries of the UV filters from the spiked formulation were between 95.7 and 103.7% and the precision of the method was better than 6.1% relative standard deviation. The developed HPLC procedure is suitable for quality control and photostability analyses of commercial suncare products.

  19. Comparative performance of PCR-based assay versus microscopy and culture for the direct detection of Mycobacterium tuberculosis in clinical respiratory specimens in Lebanon.

    Science.gov (United States)

    Araj, G F; Talhouk, R S; Itani, L Y; Jaber, W; Jamaleddine, G W

    2000-09-01

    American University of Beirut Medical Center, Lebanon. To assess the performance of a polymerase chain reaction (PCR) using primers that flank 542 bp within IS6110 in Mycobacterium tuberculosis (TB) vs. microscopy and BACTEC culture, in the diagnosis of tuberculosis. A total of 82 clinical respiratory pulmonary specimens and 73 samples from BACTEC vials were tested by the three methods. Of 24 smear-positive culture-positive (SP-CP) and 11 smear-negative culture-positive (SN-CP) TB specimens, PCR detected 83% and 64%, respectively. Among 17 specimens yielding mycobacteria other than tuberculosis (MOTT), the PCR was positive in 33% SP-CP and 14% SN-CP specimens. Among the 73 BACTEC vials, PCR was positive in 36 of 38 (95%) yielding culture-positive TB, and in one of 20 (5%) yielding culture positive MOTT. None of the 30 smear-negative culture-negative (SN-CN) clinical specimens and 15 of the CN vials were positive by PCR. The overall sensitivity of PCR was 77% and 95% for TB detection in respiratory specimens and BACTEC vials, respectively, and the specificity was 94% in both. Because a substantial number of TB cases are missed, especially in SN-CP specimens, a PCR-based assay utilizing these primers cannot be used reliably, alone, in clinical laboratory diagnosis of mycobacterial respiratory infections.

  20. Performance of a RT-PCR Assay in Comparison to FISH and Immunohistochemistry for the Detection of ALK in Non-Small Cell Lung Cancer.

    Science.gov (United States)

    Hout, David R; Schweitzer, Brock L; Lawrence, Kasey; Morris, Stephan W; Tucker, Tracy; Mazzola, Rosetta; Skelton, Rachel; McMahon, Frank; Handshoe, John; Lesperance, Mary; Karsan, Aly; Saltman, David L

    2017-08-01

    Patients with lung cancers harboring an activating anaplastic lymphoma kinase ( ALK ) rearrangement respond favorably to ALK inhibitor therapy. Fluorescence in situ hybridization (FISH) and immunohistochemistry (IHC) are validated and widely used screening tests for ALK rearrangements but both methods have limitations. The ALK RGQ RT-PCR Kit (RT-PCR) is a single tube quantitative real-time PCR assay for high throughput and automated interpretation of ALK expression. In this study, we performed a direct comparison of formalin-fixed paraffin-embedded (FFPE) lung cancer specimens using all three ALK detection methods. The RT-PCR test (diagnostic cut-off Δ C t of ≤8) was shown to be highly sensitive (100%) when compared to FISH and IHC. Sequencing of RNA detected full-length ALK transcripts or EML4-ALK and KIF5B-ALK fusion variants in discordant cases in which ALK expression was detected by the ALK RT-PCR test but negative by FISH and IHC. The overall specificity of the RT-PCR test for the detection of ALK in cases without full-length ALK expression was 94% in comparison to FISH and sequencing. These data support the ALK RT-PCR test as a highly efficient and reliable diagnostic screening approach to identify patients with non-small cell lung cancer whose tumors are driven by oncogenic ALK.

  1. Intramolecular cyclization in irradiated nucleic acids: correlation between high-performance liquid chromatography and an immunochemical assay for 8,5'-cycloadenosine in irradiated poly(A)

    International Nuclear Information System (INIS)

    Fuciarelli, A.F.; Shum, F.Y.; Raleigh, J.A.

    1987-01-01

    A correlation between high-performance liquid chromatography (HPLC) analysis and an in situ enzyme-linked immunosorbent assay (ELISA) for 8,5'-cycloadenosine formation in irradiated poly(A) has been established. The correlation shows that the ELISA precisely reflects changes in the combined yield of R- and S-8,5'-cycloadenosine but that a correction factor must be applied to the ELISA values for accuracy. The HPLC analysis reveals that the intramolecular cyclization proceeds stereoselectively in irradiated poly(A) to preferentially produce the R isomer at pH 7.0 which is similar to the result for irradiated adenosine but in contrast to the result for 5'-AMP where the S isomer predominates at neutral pH. The HPLC analysis shows that two events originating in hydroxyl radical attack at the sugar phosphate backbone in poly(A); that is, adenine release and 8,5'-cycloadenosine formation have somewhat different dose-yield responses. The formation of 8-hydroxyadenosine was detected in the HPLC chromatograms of poly(A) irradiated under N2O at neutral pH, and the yield of this compound was similar to the yield observed in 5'-AMP or adenosine irradiated under similar conditions

  2. MiR-137 inhibited cell proliferation and migration of vascular smooth muscle cells via targeting IGFBP-5 and modulating the mTOR/STAT3 signaling.

    Directory of Open Access Journals (Sweden)

    Jin Pan

    Full Text Available Abnormal proliferation of vascular smooth muscle cells (VSMCs contributes to the development of cardiovascular diseases. Studies have shown the great impact of microRNAs (miRNAs on the cell proliferation of VSMCs. This study examined the effects of miR-137 on the cell proliferation and migration of VSMCs and also explored the underlying molecular mechanisms. The mRNA and protein expression levels were determined by qRT-PCR and western blot assays, respectively. The CCK-8 assay, wound healing assay and transwell migration assay were performed to measure cell proliferation and migration of VSMCs. The miR-137-targeted 3'untranslated region of insulin-like growth factor-binding protein-5 (IGFBP-5 was confirmed by luciferase reporter assay. Platelet-derived growth factor-bb (PDGF-bb treatment enhanced cell proliferation and suppressed the expression of miR-137 in VSMCs. The gain-of-function and loss-of-function assays showed that overexpression of miR-137 suppressed the cell proliferation and migration, and also inhibited the expression of matrix genes of VSMCs; down-regulation of miR-137 had the opposite effects on VSMCs. Bioinformatics analysis and luciferase report assay results showed that IGFBP-5 was a direct target of miR-137, and miR-137 overexpression suppressed the IGFBP-5 expression and down-regulation of miR-137 increased the IGFBP-5 expression in VSMCs. PDGF-bb treatment also increased the IGFBP-5 mRNA expression. In addition, enforced expression of IGFBP-5 reversed the inhibitory effects of miR-137 on cell proliferation and migration of VSMCs. More importantly, overexpression of miR-137 also suppressed the activity of mTOR/STAT3 signaling in VSMCs. Taken together, the results suggest that miR-137 may suppress cell proliferation and migration of VSMCs via targeting IGFBP-5 and modulating mTOR/STAT3 signaling pathway.

  3. Mobile phone radiation alters proliferation of hepatocarcinoma cells.

    Science.gov (United States)

    Ozgur, Elcin; Guler, Goknur; Kismali, Gorkem; Seyhan, Nesrin

    2014-11-01

    This study investigated the effects of intermittent exposure (15 min on, 15 min off for 1, 2, 3, or 4 h, at a specific absorption rate of 2 W/kg) to enhanced data rates for global system for mobile communication evolution-modulated radiofrequency radiation (RFR) at 900- and 1,800-MHz frequencies on the viability of the Hepatocarcinoma cells (Hep G2). Hep G2 cell proliferation was measured by a colorimetric assay based on the cleavage of the tetrazolium salt WST-1 by mitochondrial dehydrogenases in viable cells. Cell injury was evaluated by analyzing the levels of lactate dehydrogenase (LDH) and glucose released from lysed cells into the culture medium. Morphological observation of the nuclei was carried out by 4',6-diamidino-2-phenylindole (DAPI) staining using fluorescence microscopy. In addition, TUNEL assay was performed to confirm apoptotic cell death. It was observed that cell viability, correlated with the LDH and glucose levels, changed according to the frequency and duration of RFR exposure. Four-hour exposure produced more pronounced effects than the other exposure durations. 1,800-MHz RFR had a larger impact on cell viability and Hep G2 injury than the RFR at 900 MHz. Morphological observations also supported the biochemical results indicating that most of the cells showed irregular nuclei pattern determined by using the DAPI staining, as well as TUNEL assay which shows DNA damage especially in the cells after 4 h of exposure to 1,800-MHz RFR. Our results indicate that the applications of 900- and 1,800-MHz (2 W/kg) RFR cause to decrease in the proliferation of the Hep G2 cells after 4 h of exposure. Further studies will be conducted on other frequency bands of RFR and longer duration of exposure.

  4. Clinical performance of LOCI™-based tumor marker assays for tumor markers CA 15-3, CA 125, CEA, CA 19-9 and AFP in gynecological cancers.

    Science.gov (United States)

    Dolscheid-Pommerich, Ramona C; Keyver-Paik, Mignon; Hecking, Thomas; Kuhn, Walther; Hartmann, Gunther; Stoffel-Wagner, Birgit; Holdenrieder, Stefan

    2017-10-01

    Evidence is sparse regarding the clinical performance of luminescent oxygen channeling immunoassays-based tumor marker assays in gynecological cancer. Analyzing serum samples of 336 patients with Dimension™Vista1500, we investigated the diagnostic power of carbohydrate antigen 15-3, carbohydrate antigen 125, carcinoembryonic antigen, carbohydrate antigen 19-9, and alpha-fetoprotein in patients suffering from different types of gynecological cancer and precancerous gynecological diseases and compared findings to appropriate control groups. The cohort comprised 177 female patients with gynecological cancers (73 breast, 22 cervical, 16 endometrial, 17 vulva, and 49 ovarian cancers), 26 patients with precancerous gynecological diseases (11 vulva, 4 cervical, and 10 breast), 109 patients with benign gynecological diseases, and 24 healthy controls. Discriminative power was assessed by areas under the curve in receiver operating characteristic curves, and sensitivities were determined at a fixed specificity of 95%. Levels of biomarkers in healthy controls were in the expected ranges and a discriminative power between gynecological cancers and healthy controls was observed for several tumor markers. Established tumor type-associated markers were elevated in specific gynecological cancers and benign controls as well as within precancerous gynecological diseases and healthy control group. In ovarian cancer, carbohydrate antigen 125 and carbohydrate antigen 15-3 were significantly elevated compared to the respective benign diseases. Carbohydrate antigen 125 was the most conclusive marker (area under the curve = 0.86% and 77.6% sensitivity at 95% specificity). In breast cancer, carcinoembryonic antigen and carbohydrate antigen 15-3 were significantly higher than in the respective benign diseases. Carcinoembryonic antigen achieved the most conclusive area under the curve (0.65) with 31.5% sensitivity at 95% specificity. None of the investigated markers was found to be of

  5. Performance of the Abbott RealTime MTB RIF/INH resistance assay when used to test Mycobacterium tuberculosis specimens from Bangladesh

    Directory of Open Access Journals (Sweden)

    Kostera J

    2018-05-01

    Full Text Available Joshua Kostera, Gregor Leckie, Klara Abravaya, Hong Wang Abbott Molecular, Abbott Laboratories, Des Plaines, IL, USA Introduction: The Abbott RealTime MTB RIF/INH Resistance Assay (RT MTB RIF/INH is an assay for the detection of rifampicin (RIF- and/or isoniazid (INH-resistant Mycobacterium tuberculosis (MTB. The assay can be used to test sputum, bronchial alveolar lavage, and N-Acetyl-L-Cysteine (NALC/NaOH pellets prepared from these samples. The assay can be used in direct testing mode, or in reflex mode following a MTB positive result produced by its companion assay, Abbott RT MTB. Methods: In this study, the direct testing mode was used to test paired sputum and NALC/NaOH pellets prepared from sputum collected from Bangladesh TB patients. One hundred and thirty two paired samples were tested. Results: The RT MTB RIF/INH inhibition rate was 0%. One hundred and twenty-two paired samples had results above the assay limit of detection and were analyzed by comparing with results from phenotypic drug sensitivity testing, GeneXpert MTB/RIF (Xpert, and MTBDR plus (Hain. RT MTB RIF/INH results were in good agreement with those of GeneXpert and Hain. Conclusion: The ability of this assay to detect RIF and INH resistance may contribute to the global control of multidrug resistant tuberculosis. Keywords: tuberculosis, rifampicin, isoniazid, resistance

  6. A flow cytometric assay for simultaneously measuring the ...

    African Journals Online (AJOL)

    This research objective was to exploit a novel method for measuring the proliferation, cytotoxicity of cytokine-induced killer (CIK) cells using carboxyfluorescein succinimidyl ester/proliferation index (CFSE/PI) and flow cytometric assay. As cells divide, CFSE is apportioned equally between the two daughter cells, leading to a ...

  7. Quantification of imatinib in human serum: validation of a high-performance liquid chromatography-mass spectrometry method for therapeutic drug monitoring and pharmacokinetic assays

    Directory of Open Access Journals (Sweden)

    Rezende VM

    2013-08-01

    Full Text Available Vinicius Marcondes Rezende,1 Ariane Rivellis,1 Mafalda Megumi Yoshinaga Novaes,1 Dalton de Alencar Fisher Chamone,2 Israel Bendit1,21Laboratory of Tumor Biology, 2Department of Hematology, School of Medicine, University of São Paulo, São Paulo, BrazilBackground: Imatinib mesylate has been a breakthrough treatment for chronic myeloid leukemia. It has become the ideal tyrosine kinase inhibitor and the standard treatment for chronic-phase leukemia. Striking results have recently been reported, but intolerance to imatinib and noncompliance with treatment remain to be solved. Molecular monitoring by quantitative real-time polymerase chain reaction is the gold standard for monitoring patients, and imatinib blood levels have also become an important tool for monitoring.Methods: A fast and cheap method was developed and validated using high-performance liquid chromatography-mass spectrometry for quantification of imatinib in human serum and tamsulosin as the internal standard. Remarkable advantages of the method includes use of serum instead of plasma, less time spent on processing and analysis, simpler procedures, and requiring reduced amounts of biological material, solvents, and reagents. Stability of the analyte was also studied. This research also intended to drive the validation scheme in clinical centers. The method was validated according to the requirements of the US Food and Drug Administration and Brazilian National Health Surveillance Agency within the range of 0.500–10.0 µg/mL with a limit of detection of 0.155 µg/mL. Stability data for the analyte are also presented.Conclusion: Given that the validated method has proved to be linear, accurate, precise, and robust, it is suitable for pharmacokinetic assays, such as bioavailability and bioequivalence, and is being successfully applied in routine therapeutic drug monitoring in the hospital service.Keywords: imatinib, high-performance liquid chromatography-mass spectrometry, therapeutic

  8. Nuclear proliferation and terrorism

    International Nuclear Information System (INIS)

    Anon.

    1977-01-01

    This section of the book, Part III, has two chapters (9 and 10). Chapter 9, Nuclear Power and Proliferation of Nuclear Weapons, is disucssed under these subjects: nuclear nonproliferation: origins and status; requirements for nuclear weapons manufacture; current nuclear programs and proliferation capabilities; encouraging decisions to forego weapons; arms control; safeguards; attitudes and expectations. Chapter 10, Nuclear Terrorism, discusses these areas: theft of nuclear materials; attacks on nuclear reactors; responding to nuclear terrorism; security and civil liberties

  9. Dual isotope assays

    International Nuclear Information System (INIS)

    Smith, G.F.W.; Stevens, R.A.J.; Jacoby, B.

    1980-01-01

    Dual isotope assays for thyroid function are performed by carrying out a radio-immunoassay for two of thyroxine (T4), tri-iodothyronine (T3), thyroid stimulating hormone (TSH), and thyroxine binding globulin (TBG), by a method wherein a version of one of the thyroid components, preferably T4 or T3 is labelled with Selenium-75 and the version of the other thyroid component is labelled with a different radionuclide, preferably Iodine-125. (author)

  10. Peroxisome proliferator activator receptor gamma coactivator-1alpha (PGC-1α improves motor performance and survival in a mouse model of amyotrophic lateral sclerosis

    Directory of Open Access Journals (Sweden)

    Cheng Alice

    2011-07-01

    Full Text Available Abstract Background Amyotrophic lateral sclerosis (ALS is a devastating neurodegenerative disease that affects spinal cord and cortical motor neurons. An increasing amount of evidence suggests that mitochondrial dysfunction contributes to motor neuron death in ALS. Peroxisome proliferator-activated receptor gamma co-activator-1α (PGC-1α is a principal regulator of mitochondrial biogenesis and oxidative metabolism. Results In this study, we examined whether PGC-1α plays a protective role in ALS by using a double transgenic mouse model where PGC-1α is over-expressed in an SOD1 transgenic mouse (TgSOD1-G93A/PGC-1α. Our results indicate that PGC-1α significantly improves motor function and survival of SOD1-G93A mice. The behavioral improvements were accompanied by reduced blood glucose level and by protection of motor neuron loss, restoration of mitochondrial electron transport chain activities and inhibition of stress signaling in the spinal cord. Conclusion Our results demonstrate that PGC-1α plays a beneficial role in a mouse model of ALS, suggesting that PGC-1α may be a potential therapeutic target for ALS therapy.

  11. Comparative analysis of proliferation resistance assessment methodologies

    International Nuclear Information System (INIS)

    Takaki, Naoyuki; Kikuchi, Masahiro; Inoue, Naoko; Osabe, Takeshi

    2005-01-01

    Comparative analysis of the methodologies was performed based on the discussions in the international workshop on 'Assessment Methodology of Proliferation Resistance for Future Nuclear Energy Systems' held in Tokyo, on March 2005. Through the workshop and succeeding considerations, it is clarified that the proliferation resistance assessment methodologies are affected by the broader nuclear options being pursued and also by the political situations of the state. Even the definition of proliferation resistance, despite the commonality of fundamental issues, derives from perceived threat and implementation circumstances inherent to the larger programs. Deep recognitions of the 'difference' among communities would help us to make further essential and progressed discussion with harmonization. (author)

  12. Effects of Plasma Rich in Growth Factors and Platelet-Rich Fibrin on Proliferation and Viability of Human Gingival Fibroblasts

    Science.gov (United States)

    Vahabi, Surena; Vaziri, Shahram; Torshabi, Maryam

    2015-01-01

    Objectives: Platelet preparations are commonly used to enhance bone and soft tissue regeneration. Considering the existing controversies on the efficacy of platelet products for tissue regeneration, more in vitro studies are required. The aim of the present study was to compare the in vitro effects of plasma rich in growth factors (PRGF) and platelet-rich fibrin (PRF) on proliferation and viability of human gingival fibroblasts (HGFs). Materials and Methods: Anitua’s PRGF and Choukran’s PRF were prepared according to the standard protocols. After culture periods of 24, 48 and 72 hours, proliferation of HGFs was evaluated by the methyl thiazol tetrazolium assay. Statistical analysis was performed using one-way ANOVA followed by Tukey-Kramer’s multiple comparisons and P-valuesPRGF treatment induced statistically significant (PPRGF than in PRF group (PPRGF had a strong stimulatory effect on HGF cell viability and proliferation compared to PRF. PMID:26877740

  13. Development and performance assessment of a luminex xMAP® direct hybridization assay for the detection and identification of indoor air fungal contamination.

    Science.gov (United States)

    Libert, Xavier; Packeu, Ann; Bureau, Fabrice; Roosens, Nancy H; De Keersmaecker, Sigrid C J

    2017-01-01

    Considered as a public health problem, indoor fungal contamination is generally monitored using classical protocols based on culturing. However, this culture dependency could influence the representativeness of the fungal population detected in an analyzed sample as this includes the dead and uncultivable fraction. Moreover, culture-based protocols are often time-consuming. In this context, molecular tools are a powerful alternative, especially those allowing multiplexing. In this study a Luminex xMAP® assay was developed for the simultaneous detection of 10 fungal species which are most frequently in indoor air and that may cause health problems. This xMAP® assay was found to be sensitive, i.e. its limit of detection is ranging between 0.05 and 0.01 ng of gDNA. The assay was subsequently tested with environmental air samples which were also analyzed with a classical protocol. All the species identified with the classical method were also detected with the xMAP® assay, however in a shorter time frame. These results demonstrate that the Luminex xMAP® fungal assay developed in this study could contribute to the improvement of public health and specifically to the indoor fungal contamination treatment.

  14. Development and performance assessment of a luminex xMAP® direct hybridization assay for the detection and identification of indoor air fungal contamination.

    Directory of Open Access Journals (Sweden)

    Xavier Libert

    Full Text Available Considered as a public health problem, indoor fungal contamination is generally monitored using classical protocols based on culturing. However, this culture dependency could influence the representativeness of the fungal population detected in an analyzed sample as this includes the dead and uncultivable fraction. Moreover, culture-based protocols are often time-consuming. In this context, molecular tools are a powerful alternative, especially those allowing multiplexing. In this study a Luminex xMAP® assay was developed for the simultaneous detection of 10 fungal species which are most frequently in indoor air and that may cause health problems. This xMAP® assay was found to be sensitive, i.e. its limit of detection is ranging between 0.05 and 0.01 ng of gDNA. The assay was subsequently tested with environmental air samples which were also analyzed with a classical protocol. All the species identified with the classical method were also detected with the xMAP® assay, however in a shorter time frame. These results demonstrate that the Luminex xMAP® fungal assay developed in this study could contribute to the improvement of public health and specifically to the indoor fungal contamination treatment.

  15. Specific high-performance liquid chromatographic assay with ultraviolet detection for the determination of 1-(2-chloroethyl)-3-sarcosinamide-1-nitrosourea in plasma.

    Science.gov (United States)

    Supko, J G; Phillips, L R; Malspeis, L

    1996-03-03

    A facile, sensitive and highly specific HPLC method for assaying 1-(2-chloroethyl)-3-sarcosinamide-1-nitrosourea (SarCNU) in plasma has been developed. The drug was efficiently isolated from plasma by extraction with tert.-butyl methyl ether. A structurally related compound with similar physicochemical properties served as the internal standard (I.S.). Following evaporation of the organic solvent, the extract was reconstituted with 0.05 M ammonium acetate buffer, pH 5.0, and loaded onto a 4 micron Nova-Pak C18 column (15 cm x 3.9 mm), which was preceded by a 7 micron Brownlee RP-18 precolumn (1.5 cm x 3.2 mm). Chromatography was performed at ambient temperature using a mobile phase of methanol-0.1 M ammonium formate buffer, pH 3.7 (25:75, v/v). UV absorbance of the effluent was monitored at 240 nm. A flow-rate of 1.0 ml/ min was used for analyzing mouse and dog plasma extracts. Under these conditions, the drug eluted at 4.0 min and was followed by the I.S. at 6.1 min. An automatic switching valve was employed to allow the precolumn to be flushed 1.5 min into the run, without interrupting the flow of the mobile phase to the analytical column, thereby preventing the apparent build-up of extractable, strongly retained, UV-absorbing components present in mouse and dog plasma. Operating in this manner, more than 100 samples could be analyzed during a day using a refrigerated autosampler for overnight injection. The method was readily adapted to the determination of SarCNU in human plasma by simply decreasing the eluent flow-rate to 0.6 ml/min, whereby SarCNU and the I.S. eluted at approximately 5.8 and 9.1 min, respectively. Furthermore, the switching valve was not necessary for the analysis of human plasma samples. With a 50-microliter sample volume, the lowest concentration of SarCNU included in the plasma standard curves, 0.10 micrograms/ml, was quantified with a 7.8% R.S.D. (n = 27) over a 2 month period. Plasma standards, with concentrations of 0.26 to 5

  16. Nuclear non-proliferation

    International Nuclear Information System (INIS)

    Anon.

    1984-01-01

    DOE's nuclear non-proliferation responsibilities are defined by the provisions of the Atomic Energy Act of 1954, as amended, and of the Nuclear Non-Proliferation Act of 1978 (NNPA). The Department's major responsibilities in this area are to: (1) provide technical assistance to the Department of State in negotiating agreements for civil cooperation in the peaceful uses of nuclear energy with other countries and international organizations; (2) join with other agencies to reach executive branch judgments with respect to the issuance of export licenses by the Nuclear Regulatory Commission; (3) be responsible for processing subsequent arrangements with other agencies as required by the Nuclear Non-Proliferation Act; (4) control the distribution of special nuclear materials, components, equipment, and nuclear technology exports; (5) participate in bilateral and multilateral cooperation with foreign governments and organizations to promote the peaceful uses of nuclear energy; and (6) act as a primary technical resource with respect to US participation in the International Atomic Energy Agency

  17. Dynamics of nuclear proliferation

    International Nuclear Information System (INIS)

    Meyer, S.M.

    1984-01-01

    This book looks beyond policy disputes to make a systematic examination of the assumptions and contending hypotheses that constitute contemporary thinking on nuclear proliferation. Rather than determine who is right or wrong, the intent is to develop a better picture by using the various schools of thought as analytic windows. A better understanding of how the process operates should offer better guidance for predicting future nuclear proliferation and, ultimately, for controlling it. Separate chapters deal with the contending views, the technological and motivational bases of nuclear proliferation, the presence of a technological imperative, testing the motivational hypothesis, the dynamics of the process, and forecasting. Four appendices present historical decisions, the technical model, cost-estimating procedures, and procedures for estimating nuclear propensities. 288 references, 17 figures, 26 tables

  18. miR-32 inhibits proliferation, epithelial–mesenchymal transition, and metastasis by targeting TWIST1 in non-small-cell lung cancer cells

    Directory of Open Access Journals (Sweden)

    Li L

    2016-03-01

    Full Text Available Lei Li,1,* Dapeng Wu2,* 1Department of Pneumology, 2Department of Radiotherapy, Huaihe Hospital of Henan University, Kaifeng, Henan, People’s Republic of China *These authors contributed equally to this work Background: By analyzing published microRNA microarray studies, miR-32 was found to be markedly reduced in non-small-cell lung cancer (NSCLC tissues compared with that in nontumor tissues. However, little is known about its role and molecular mechanism involved in NSCLC development and progression. Here, we report the effect of miR-32 on NSCLC cell proliferation, epithelial–mesenchymal transition (EMT, and metastasis. Methods: Quantitative real-time PCR was performed to detect the expression level of miR-32 in primary NSCLC cases and cell lines. miR-32-overexpressing H1299 and A549 cells were constructed by lipofection transfection. MTT, transwell chamber, and Western blot assays were used to assess the effect of miR-32 on proliferation, EMT, and metastasis of NSCLC cells, respectively. Target prediction and luciferase reporter assays were performed to investigate the targets of miR-32. Tumor formation assay in vivo was performed to investigate the antitumor effect of miR-32. Results: An inverse correlation existed between miR-32 expression level and NSCLC cell proliferation, EMT, and metastasis, and upregulation of miR-32 repressed NSCLC cell proliferation, EMT, and metastasis. Moreover, we identified and validated that TWIST1 was a direct target of miR-32, and miR-32 regulated NSCLC cell proliferation, EMT, and metastasis, at least in part via modulation of TWIST1. The animal experiments showed that overexpression of miR-32 inhibited the growth of NSCLC tumors in vivo. Keywords: non-small-cell lung cancer, miR-32, TWIST1, proliferation, EMT, nude mice

  19. Proliferation resistance modeling

    International Nuclear Information System (INIS)

    Bari, R.; Peterson, P.; Roglans, J.; Mladineo, S.; Nuclear Engineering Division; BNL; Univ. of California at Berkely; PNNL

    2004-01-01

    The National Nuclear Security Administration is developing methods for nonproliferation assessments. A working group on Nonproliferation Assessment Methodology (NPAM) assembled a toolbox of methods for various applications in the nonproliferation arena. One application of this methodology is to the evaluation of the proliferation resistance of Generation IV nuclear energy systems. This paper first summarizes the key results of the NPAM program and then provides results obtained thus far in the ongoing application, which is co-sponsored by the DOE Office of Nuclear Energy Science and Technology. In NPAM, a top-level measure of proliferation resistance for a fuel cycle system is developed from a hierarchy of metrics. The problem is decomposed into: metrics to be computed, barriers to proliferation, and a finite set of threats. The analyst models the process undertaken by the proliferant to overcome barriers to proliferation and evaluates the outcomes. In addition to proliferation resistance (PR) evaluation, the application also addresses physical protection (PP) evaluation against sabotage and theft. The Generation IV goal for future nuclear energy systems is to assure that they are very unattractive and the least desirable route for diversion or theft of weapons-usable materials, and provide increased physical protection against terrorism. An Expert Group, addressing this application, has identified six high-level measures for the PR goals (six measures have also been identified for the PP goals). Combined together, the complete set of measures provides information for program policy makers and system designers to compare specific system design features and integral system characteristics and to make choices among alternative options. The Group has developed a framework for a phased evaluation approach to analyzing PR and PP of system characteristics and to quantifying metrics and measures. This approach allows evaluations to become more detailed and representative

  20. Diagnostic performance of HPV E6/E7 mRNA assay for detection of cervical high-grade intraepithelial neoplasia and cancer among women with ASCUS Papanicolaou smears.

    Science.gov (United States)

    Ren, Chenchen; Zhu, Yuanhang; Yang, Li; Zhang, Xiaoan; Liu, Ling; Ren, Chunying

    2018-02-01

    The aim of this study was to investigate the clinical performance of high risk (HR) HPV E6/E7 mRNA assay in detecting cervical high-grade intraepithelial neoplasia and cancer among women with atypical squamous cells of undetermined significance (ASCUS) Papanicolaou (Pap) smears. A total of 160 patients with ASCUS who underwent HR-HPV DNA assay, HR-HPV E6/E7 mRNA assay and colposcopy biopsy at Third Affiliated Hospital of Zhengzhou University, China, from December 2015 to March 2017, were enrolled. Logistic regression analysis was used to evaluate the relationship between pathological results with clinical biologic factors. Univariate analysis showed that the qualitative results of HR-HPV DNA, qualitative results of HR-HPV E6/E7 mRNA and expression levels of HR-HPV E6/E7 mRNA were risk factors of high-grade cervical intraepithelial neoplasia (CIN) and cervical cancer (all P HPV E6/E7 mRNA was associated with high-grade CIN and cervical cancer (OR = 8.971, 95% CI = 2.572-31.289, P = 0.001). An optimal cut-off value of ≥ 558.26 copies/ml was determined using receiver operating characteristic curve, and specificity of cut-off value were higher than E6/E7 mRNA qualitative assay and DNA qualitative assay. HPV E6/E7 mRNA quantitative assay may be a valuable tool in triage of ASCUS pap smears. A high specificity of E6/E7 mRNA quantitative assay as a triage test in women with ASCUS can be translated into a low referral for colposcopy.

  1. Mistaken identity of an open reading frame proposed for PCR-based identification of Mycoplasma bovis and the effect of polymorphisms and insertions on assay performance

    Science.gov (United States)

    Mycoplasma bovis is an important cause of disease in cattle and bison. Because the bacterium requires specialized growth conditions many diagnostic laboratories routinely use PCR to replace or complement conventional isolation and identification methods. A frequently used target of such assays is th...

  2. Effects of Plasma Rich in Growth Factors and Platelet-Rich Fibrin on Proliferation and Viability of Human Gingival Fibroblasts

    Directory of Open Access Journals (Sweden)

    Surena Vahabi

    2016-01-01

    Full Text Available Objectives: Platelet preparations are commonly used to enhance bone and soft tissue regeneration. Considering the existing controversies on the efficacy of platelet products for tissue regeneration, more in vitro studies are required. The aim of the present study was to compare the in vitro effects of plasma rich in growth factors (PRGF and platelet-rich fibrin (PRF on proliferation and viability of human gingival fibroblasts (HGFs.Materials and Methods: Anitua's PRGF and Choukran's PRF were prepared according to the standard protocols. After culture periods of 24, 48 and 72 hours, proliferation of HGFs was evaluated by the methyl thiazol tetrazolium assay. Statistical analysis was performed using one-way ANOVA followed by Tukey-Kramer’s multiple comparisons and P-values<0.05 were considered statistically significant.Results: PRGF treatment induced statistically significant (P<0.001 proliferation of HGF cells compared to the negative control (100% viability at 24, 48 and 72 hours in values of 123%±2.25%, 102%±2.8% and 101%±3.92%, respectively. The PRF membrane treatment of HGF cells had a statistically significant effect on cell proliferation (21%±1.73%, P<0.001 at 24 hours compared to the negative control. However, at 48 and 72 hours after treatment, PRF had a negative effect on HGF cell proliferation and caused 38% and 60% decrease in viability and proliferation compared to the negative control, respectively. The HGF cell proliferation was significantly higher in PRGF than in PRF group (P< 0.001.Conclusion: This study demonstrated that PRGF had a strong stimulatory effect on HGF cell viability and proliferation compared to PRF.

  3. Cell Proliferation in Neuroblastoma

    Science.gov (United States)

    Stafman, Laura L.; Beierle, Elizabeth A.

    2016-01-01

    Neuroblastoma, the most common extracranial solid tumor of childhood, continues to carry a dismal prognosis for children diagnosed with advanced stage or relapsed disease. This review focuses upon factors responsible for cell proliferation in neuroblastoma including transcription factors, kinases, and regulators of the cell cycle. Novel therapeutic strategies directed toward these targets in neuroblastoma are discussed. PMID:26771642

  4. Controlling nuclear proliferation

    International Nuclear Information System (INIS)

    Sweet, W.

    1981-01-01

    Nuclear non-proliferation policy depends on the 1968 Non-Proliferation Treaty, in which countries promise not to acquire nuclear weapons in exchange for open access to peaceful nuclear technology, and a system of international safeguards that are imposed on exported nuclear equipment and facilities operated by parties to the treaty. Critics have feared all along that non-nuclear countries might circumvent or exploit the system to obtain nuclear weapons and that the Atoms for Peace plan would spread the very technology it sought to control. The nuclear weapons states would like everyone else to believe that atomic bombs are undesirable, but they continue to rely on the bombs for their own defense. Israel's raid on Iraq's nuclear reactor focused world attention on the proliferation problem and helped to broaden and sterengthen its prospects. It also highlighted the weakness that there are no effective sanctions against violators. Until the international community can ageee on enforcement measures powerful enough to prevent nuclear proliferation, individual countries may be tempted to follow Israel's example, 19 references

  5. Measurement of gene expression in archival paraffin-embedded tissues: development and performance of a 92-gene reverse transcriptase-polymerase chain reaction assay.

    Science.gov (United States)

    Cronin, Maureen; Pho, Mylan; Dutta, Debjani; Stephans, James C; Shak, Steven; Kiefer, Michael C; Esteban, Jose M; Baker, Joffre B

    2004-01-01

    Throughout the last decade many laboratories have shown that mRNA levels in formalin-fixed and paraffin-embedded (FPE) tissue specimens can be quantified by reverse transcriptase-polymerase chain reaction (RT-PCR) techniques despite the extensive RNA fragmentation that occurs in tissues so preserved. We have developed RT-PCR methods that are sensitive, precise, and that have multianalyte capability for potential wide use in clinical research and diagnostic assays. Here it is shown that the extent of fragmentation of extracted FPE tissue RNA significantly increases with archive storage time. Probe and primer sets for RT-PCR assays based on amplicons that are both short and homogeneous in length enable effective reference gene-based data normalization for cross comparison of specimens that differ substantially in age. A 48-gene assay used to compare gene expression profiles from the same breast cancer tissue that had been either frozen or FPE showed very similar profiles after reference gene-based normalization. A 92-gene assay, using RNA extracted from three 10- micro m FPE sections of archival breast cancer specimens (dating from 1985 to 2001) yielded analyzable data for these genes in all 62 tested specimens. The results were substantially concordant when estrogen receptor, progesterone receptor, and HER2 receptor status determined by RT-PCR was compared with immunohistochemistry assays for these receptors. Furthermore, the results highlight the advantages of RT-PCR over immunohistochemistry with respect to quantitation and dynamic range. These findings support the development of RT-PCR analysis of FPE tissue RNA as a platform for multianalyte clinical diagnostic tests.

  6. Comparison of Simplexa universal direct PCR with cytotoxicity assay for diagnosis of Clostridium difficile infection: performance, cost, and correlation with disease.

    Science.gov (United States)

    Landry, Marie L; Ferguson, David; Topal, Jeffrey

    2014-01-01

    Simplexa Clostridium difficile universal direct PCR, a real-time PCR assay for the detection of the C. difficile toxin B (tcdB) gene using the 3M integrated cycler, was compared with a two-step algorithm which includes the C. Diff Chek-60 glutamate dehydrogenase (GDH) antigen assay followed by cytotoxin neutralization. Three hundred forty-two liquid or semisolid stools submitted for diagnostic C. difficile testing, 171 GDH antigen positive and 171 GDH antigen negative, were selected for the study. All samples were tested by the C. Diff Chek-60 GDH antigen assay, cytotoxin neutralization, and Simplexa direct PCR. Of 171 GDH-positive samples, 4 were excluded (from patients on therapy or from whom duplicate samples were obtained) and 88 were determined to be true positives for toxigenic C. difficile. Of the 88, 67 (76.1%) were positive by the two-step method and 86 (97.7%) were positive by PCR. Seventy-nine were positive by the GDH antigen assay only. Of 171 GDH antigen-negative samples, none were positive by PCR. One antigen-negative sample positive by the cytotoxin assay only was deemed a false positive based on chart review. Simplexa C. difficile universal direct PCR was significantly more sensitive for detecting toxigenic C. difficile bacteria than cytotoxin neutralization (P = 0.0002). However, most PCR-positive/cytotoxin-negative patients did not have clear C. difficile disease. The estimated cost avoidance provided by a more rapid molecular diagnosis was outweighed by the cost of isolating and treating PCR-positive/cytotoxin-negative patients. The costs, clinical consequences, and impact on nosocomial transmission of treating and/or isolating patients positive for toxigenic C. difficile by PCR but negative for in vivo toxin production merit further study.

  7. Review on the acute Daphnia magna toxicity test – Evaluation of the sensitivity and the precision of assays performed with organisms from laboratory cultures or hatched from dormant eggs

    Directory of Open Access Journals (Sweden)

    Persoone G.

    2009-08-01

    “Culture/maintenance free” aquatic microbiotests with species of different phylogenetic groups were developed in the early 1990s at the Laboratory for Environmental Toxicology and Aquatic Ecology at the Ghent University in Belgium. These assays which were given the generic name “Toxkits”, are unique in that they employ dormant stages (“cryptobiotic eggs” of the test species, which can be stored for long periods of time and “hatched” at the time of performance of the assays. One of these microbiotests is the Daphtoxkit F magna, which is currently used in many laboratories worldwide for research as well as for toxicity monitoring purposes. The microbiotest technology has several advantages in comparison to the “traditional” tests based on laboratory cultures, especially its independence of the stock culturing burden. However, the acceptance (or possible non-acceptance of performing assays with test organisms obtained from “dormant eggs” should be clearly dictated by the “sensitivity” and “precision” criteria of the former assays in comparison to the latter. The first part of this review therefore thoroughly reviews the scientific literature and of data obtained from various laboratories for assays performed with either D. magna test organisms obtained from lab cultures or hatched from dormant eggs. Attention has focused on data of quality control tests performed on reference chemicals, and in particular on potassium dichromate (K2Cr2O7 for which an acceptability range of 0.6–2.1 mg·L–1 has been set in ISO standard 6341 for the 24 h EC50 of the acute D. magna assay. Mean EC50s, standard deviations and variation coefficients were calculated from the collected data, all of which are presented in tables and figures and discussed in detail. The major conclusions drawn from the analysis of the large number of quality control (QC data on the acute D. magna toxicity test are that : (1 Virtually all results from assays performed with

  8. Data transformation methods for multiplexed assays

    Science.gov (United States)

    Tammero, Lance F. Bentley; Dzenitis, John M; Hindson, Benjamin J

    2013-07-23

    Methods to improve the performance of an array assay are described. A correlation between fluorescence intensity-related parameters and negative control values of the assay is determined. The parameters are then adjusted as a function of the correlation. As a result, sensitivity of the assay is improved without changes in its specificity.

  9. [Lentivirus-mediated shRNA silencing of LAMP2A inhibits the proliferation of multiple myeloma cells].

    Science.gov (United States)

    Li, Lixuan; Li, Jia

    2015-05-01

    To study the effects of lentivirus-mediated short hairpin RNA (shRNA) silencing of lysosome-associated membrane protein type 2A (LAMP2A) expression on the proliferation of multiple myeloma cells. The constructed shRNA lentiviral vector was applied to infect human multiple myeloma cell line MM.1S, and stable expression cell line was obtained by puromycin screening. Western blotting was used to verify the inhibitory effect on LAMP2A protein expression. MTT assay was conducted to detect the effect of knocked-down LAMP2A on MM.1S cell proliferation, and the anti-tumor potency of suberoylanilide hydroxamic acid (SAHA) against the obtained MM.1S LAMP2A(shRNA) stable cell line. Lactate assay was performed to observe the impact of low LAMP2A expression on cell glycolysis. The stable cell line with low LAMP2A expression were obtained with the constructed human LAMP2A-shRNA lentiviral vector. Down-regulation of LAMP2A expression significantly inhibited MM.1S cell proliferation and enhanced the anti-tumor activity of SAHA. Interestingly, decreased LAMP2A expression also inhibited MM.1S cell lactic acid secretion. Down-regulation of LAMP2A expression could inhibit cell proliferation in multiple myeloma cells.

  10. Forkhead box K2 inhibits the proliferation, migration, and invasion of human glioma cells and predicts a favorable prognosis.

    Science.gov (United States)

    Wang, Bo; Zhang, XueBin; Wang, Wei; Zhu, ZhiZhong; Tang, Fan; Wang, Dong; Liu, Xi; Zhuang, Hao; Yan, XiaoLing

    2018-01-01

    Forkhead box K2 (FOXK2) is a member of the forkhead box family of transcription factors. Recently, researchers discovered that overexpression of FOXK2 inhibits the proliferation and metastasis of breast cancer, non-small cell lung cancer, and colorectal cancer, and is related to the clinical prognosis. However, in hepatocellular carcinoma, FOXK2 results in the opposite phenotypes. Currently, the contribution of FOXK2 to glioma pathogenesis is not clear. We evaluated the expression of FOXK2 in 151 glioma patients using immunohistochemistry assays. The associations among the expression of FOXK2, clinicopathological parameters, and the prognosis of glioma patients were statistically analyzed. We downregulated and upregulated the level of FOXK2 in glioma cells by transfections with small interfering RNA and plasmids. Then, we investigated the effects on tumor cell behavior in vitro by Cell Counting Kit-8 assays, colony-formation assay, transwell assay, and the epithelial-to-mesenchymal transition (EMT) biomarker levels. The clinical data showed that expression of FOXK2 gradually decreased with increasing World Health Organization (WHO) grades and a low level of FOXK2 indicates a poor prognosis. FOXK2 expression is negatively correlated with Ki67 expression and the WHO degree but is not correlated with other clinicopathological parameters, including sex, age, Karnofsky Performance Status, tumor diameter, O -6-methylguanine-DNA methyltransferase, and glutathione S -transferase pi. FOXK2 knockdown enhances glioma cell proliferation, migration, invasion, and EMT process, and, in contrast, FOXK2 overexpression inhibits glioma cell proliferation, migration, invasion, and the EMT process. Expression of FOXK2 gradually decreases with increasing WHO grades. FOXK2 inhibits tumor proliferation, migration, and invasion. FOXK2 is a critical mediator of the EMT process.

  11. PKI-587 and sorafenib alone and in combination on inhibition of liver cancer stem cell proliferation.

    Science.gov (United States)

    Gedaly, Roberto; Galuppo, Roberto; Musgrave, Yolanda; Angulo, Paul; Hundley, Jonathan; Shah, Malay; Daily, Michael F; Chen, Changguo; Cohen, Donald A; Spear, Brett T; Evers, B Mark

    2013-11-01

    Deregulated Ras/Raf/mitogen-activated protein kinase and PI3 K/AKT/mTOR signaling pathways are significant in hepatocellular carcinoma proliferation (HCC). In this study we evaluated differences in the antiproliferative effect of dual PI3 K/Akt/mTOR and Ras/Raf/mitogen-activated protein kinase inhibition of non liver cancer stem cell lines (PLC and HuH7) and liver cancer stem cell (LCSC) lines (CD133, CD44, CD24, and aldehyde dehydrogenase 1-positive cells). Flow cytometry was performed on the resulting tumors to identify the LCSC markers CD133, CD44, CD24, and aldehyde dehydrogenase 1. Methylthiazol tetrazolium assay was used to assess cellular proliferation. Finally, a Western blot assay was used to evaluate for inhibition of specific enzymes in these two signaling pathways. Using flow cytometry, we found that LCSC contain 64.4% CD133 + cells, 83.2% CD44 + cells, and 96.4% CD24 + cells. PKI-587 and sorafenib caused inhibiton of LCSC and HCC cell proliferation. PLC cells were more sensitive to PKI-587 than LCSC or Huh7 (P PKI-587 and sorafenib caused significantly more inhibition than monotherapy in HuH7, PLC, and LCSC. Using the methylthiazol tetrazolium assay, we found that the LCSC proliferation was inhibited with sorafenib monotherapy 39% at 5 μM (P PKI-587 at 0.1 μM (P = 0.002, n = 12) compared with control. The combination of PKI-587 and sorafenib, however, synergistically inhibited LCSC proliferation by 86% (P = 0.002; n = 12). LCSC (CD133+, CD44+, CD24+) were able to develop very aggressive tumors with low cell concentrations at 4 to 6 wk. Cells CD133+, CD44+, CD24+, which demonstrated at least moderate resistance to therapy in vitro. The combination of PKI-587 and sorafenib was better than either drug alone at inhibiting of LCSC and on HCC cell proliferation. Copyright © 2013 Elsevier Inc. All rights reserved.

  12. Six2 Is a Coordinator of LiCl-Induced Cell Proliferation and Apoptosis

    Directory of Open Access Journals (Sweden)

    Jianing Liu

    2016-09-01

    Full Text Available The metanephric mesenchyme (MM cells are a subset of kidney progenitor cells and play an essential role in mesenchymal-epithelial transition (MET, the key step of nephron generation. Six2, a biological marker related to Wnt signaling pathway, promotes the proliferation, inhibits the apoptosis and maintains the un-differentiation of MM cells. Besides, LiCl is an activator of Wnt signaling pathway. However, the role of LiCl in cellular regulation of MM cells remains unclear, and the relationship between LiCl and Six2 in this process is also little known. Here, we performed EdU assay and flow cytometry assay to, respectively, detect the proliferation and apoptosis of MM cells treated with LiCl of increasing dosages. In addition, reverse transcription-PCR (RT-PCR and Western-blot were conducted to measure the expression of Six2 and some maker genes of Wnt and bone-morphogenetic-protein (BMP signaling pathway. Furthermore, luciferase assay was also carried out to detect the transcriptional regulation of Six2. Then we found LiCl promoted MM cell proliferation at low-concentration (10, 20, 30, and 40 mM. The expression of Six2 was dose-dependently increased in low-concentration (10, 20, 30, and 40 mM at both mRNA and protein level. In addition, both of cell proliferation and Six2 expression in MM cells declined when dosage reached high-concentration (50 mM. However, Six2 knock-down converted the proliferation reduction at 50 mM. Furthermore, Six2 deficiency increased the apoptosis of MM cells, compared with negative control cells at relative LiCl concentration. However, the abnormal rise of apoptosis at 30 mM of LiCl concentration implies that it might be the reduction of GSK3β that increased cell apoptosis. Together, these demonstrate that LiCl can induce the proliferation and apoptosis of MM cells coordinating with Six2.

  13. Effect of pirfenidone on the proliferation of rat corneal stromal cells

    Directory of Open Access Journals (Sweden)

    Jun-Jie Chen

    2015-02-01

    Full Text Available AIM: To investigate the effects of pirfenidone(PFDon the proliferation and transfomring growth factor-β1(TGF-β1expression in vitro culture rat corneal stromal cells. METHODS: Corneal stromal cells from 8 to 10wk SD rats were isolated, cultured and treated with different concentrations of PFD 0mg/mL(control group, 0.15mg/mL(experimental group Ⅰ, 0.3mg/mL(experimental group Ⅱ, 1mg/mL(experimental group Ⅲfor 48h. CCK-8 assay was performed to assess cell proliferation, while immunocytochemistry and Western Blot were used to detect the expression of ki-67 and TGF-β1 expression, respectively. RESULTS: Compared with control group, PFD significantly inhibited the proliferation in a dose-dependent manner(all P1 in a dose-dependent manner(PCONCLUSION: Pirfenidone can significantly inhibit the proliferation of rat corneal stromal cell by down regulating TGF-β1 expression, therefore, it has potential prospect in lightening the corneal wound healing reaction.

  14. Proliferation and differentiation of stem cells in contact with eluate from fibrin-rich plasma membrane

    Directory of Open Access Journals (Sweden)

    Fernanda Gimenez de Souza

    Full Text Available ABSTRACT Objective: To evaluate the ability of the eluate from fibrin-rich plasma (FRP membrane to induce proliferation and differentiation of isolated human adipose-derived stem cells (ASCs into chondrocytes. Method: FRP membranes were obtained by centrifugation of peripheral blood from two healthy donors, cut, and maintained in culture plate wells for 48 h to prepare the fibrin eluate. The SCATh were isolated from adipose tissue by collagenase digestion solution, and expanded in vitro. Cells were expanded and treated with DMEM-F12 culture, a commercial media for chondrogenic differentiation, and eluate from FRP membrane for three days, and labeled with BrdU for quantitative assessment of cell proliferation using the High-Content Operetta® imaging system. For the chondrogenic differentiation assay, the SCATh were grown in micromass for 21 days and stained with toluidine blue and aggrecan for qualitative evaluation by light microscopy. The statistical analysis was performed using ANOVA and Tukey's test. Results: There was a greater proliferation of cells treated with the eluate from FRP membrane compared to the other two treatments, where the ANOVA test showed significance (p < 0.001. The differentiation into chondrocytes was visualized by the presence of mucopolysaccharide in the matrix of the cells marked in blue toluidine and aggrecan. Conclusions: Treatment with eluate from FRP membrane stimulated cell proliferation and induced differentiation of the stem cells into chondrocytes, suggesting a potential application of FRP membranes in hyaline cartilage regeneration therapies.

  15. Adipose tissue-derived stem cells promote pancreatic cancer cell proliferation and invasion

    International Nuclear Information System (INIS)

    Ji, S.Q.; Cao, J.; Zhang, Q.Y.; Li, Y.Y.; Yan, Y.Q.; Yu, F.X.

    2013-01-01

    To explore the effects of adipose tissue-derived stem cells (ADSCs) on the proliferation and invasion of pancreatic cancer cells in vitro and the possible mechanism involved, ADSCs were cocultured with pancreatic cancer cells, and a cell counting kit (CCK-8) was used to detect the proliferation of pancreatic cancer cells. ELISA was used to determine the concentration of stromal cell-derived factor-1 (SDF-1) in the supernatants. RT-PCR was performed to detect the expression of the chemokine receptor CXCR4 in pancreatic cancer cells and ADSCs. An in vitro invasion assay was used to measure invasion of pancreatic cancer cells. SDF-1 was detected in the supernatants of ADSCs, but not in pancreatic cancer cells. Higher CXCR4 mRNA levels were detected in the pancreatic cancer cell lines compared with ADSCs (109.3±10.7 and 97.6±7.6 vs 18.3±1.7, respectively; P<0.01). In addition, conditioned medium from ADSCs promoted the proliferation and invasion of pancreatic cancer cells, and AMD3100, a CXCR4 antagonist, significantly downregulated these growth-promoting effects. We conclude that ADSCs can promote the proliferation and invasion of pancreatic cancer cells, which may involve the SDF-1/CXCR4 axis

  16. Adipose tissue-derived stem cells promote pancreatic cancer cell proliferation and invasion

    Energy Technology Data Exchange (ETDEWEB)

    Ji, S.Q.; Cao, J. [Department of Liver Surgery I, Eastern Hepatobiliary Surgery Hospital, Second Military Medical University, Shanghai (China); Zhang, Q.Y.; Li, Y.Y. [Department of Hepatobiliary and Pancreatic Surgery, The First Affiliated Hospital, Wenzhou Medical College, Wenzhou (China); Yan, Y.Q. [Department of Liver Surgery I, Eastern Hepatobiliary Surgery Hospital, Second Military Medical University, Shanghai (China); Yu, F.X. [Department of Hepatobiliary and Pancreatic Surgery, The First Affiliated Hospital, Wenzhou Medical College, Wenzhou (China)

    2013-09-27

    To explore the effects of adipose tissue-derived stem cells (ADSCs) on the proliferation and invasion of pancreatic cancer cells in vitro and the possible mechanism involved, ADSCs were cocultured with pancreatic cancer cells, and a cell counting kit (CCK-8) was used to detect the proliferation of pancreatic cancer cells. ELISA was used to determine the concentration of stromal cell-derived factor-1 (SDF-1) in the supernatants. RT-PCR was performed to detect the expression of the chemokine receptor CXCR4 in pancreatic cancer cells and ADSCs. An in vitro invasion assay was used to measure invasion of pancreatic cancer cells. SDF-1 was detected in the supernatants of ADSCs, but not in pancreatic cancer cells. Higher CXCR4 mRNA levels were detected in the pancreatic cancer cell lines compared with ADSCs (109.3±10.7 and 97.6±7.6 vs 18.3±1.7, respectively; P<0.01). In addition, conditioned medium from ADSCs promoted the proliferation and invasion of pancreatic cancer cells, and AMD3100, a CXCR4 antagonist, significantly downregulated these growth-promoting effects. We conclude that ADSCs can promote the proliferation and invasion of pancreatic cancer cells, which may involve the SDF-1/CXCR4 axis.

  17. Making transuranic assay measurements using modern controllers

    International Nuclear Information System (INIS)

    Kuckertz, T.H.; Caldwell, J.T.; Medvick, P.A.; Kunz, W.E.; Hastings, R.D.

    1987-01-01

    This paper describes methodology and computer-controlled instrumentation developed at the Los Alamos National Laboratory that accurately performs nondestructive assays of large containers bearing transuranic wastes and nonradioactive matrix materials. These assay systems can measure fissile isotopes with 1-mg sensitivity and spontaneous neutron-emitting isotopes at a 10-mg sensitivity. The assays are performed by neutron interrogation, detection, and counting in a custom assay chamber. An International Business Machines Personal Computer (IBM-PC) is used to control the CAMAC-based instrumentation system that acquires the assay data. 6 refs., 7 figs

  18. Review on the acute Daphnia magna toxicity test – Evaluation of the sensitivity and the precision of assays performed with organisms from laboratory cultures or hatched from dormant eggs

    Directory of Open Access Journals (Sweden)

    G. Persoone

    2009-08-01

    Full Text Available One of the most internationally used bioassays for toxicity screening of chemicals and for toxicity monitoring of effluents and contaminated waters is the acute toxicity test with daphnid crustaceans, and in particular that performed with Daphnia magna.Standard methods have been developed for this assay that were gradually endorsed by national and international organisations dealing with toxicity testing procedures, in view of its application within a regulatory framework. As for all toxicity tests, the organisms used for the acute D. magna assay have to be obtained from live stocks which are cultured in the laboratory on live food (micro-algae.Unsurprisingly the various standard protocols of this particular assay differ – at least to a certain extent – with regard to the test organism culturing conditions. In addition, some technical aspects of the toxicity test such as the effect criterion (mortality of immobility, the exposure time, the type of dilution water, etc., also vary from one standard to another.Although this particular assay is currently used in many countries, the technical and biological problems inherent in year-round culturing and availability of the biological material and the culturing/maintenance costs of live stocks restrict its application to a limited number of highly specialised laboratories.This fundamental bottleneck in toxicity testing triggered investigations which brought forward the concept of “microbiotests” or “small-scale” toxicity tests. “Culture/maintenance free” aquatic microbiotests with species of different phylogenetic groups were developed in the early 1990s at the Laboratory for Environmental Toxicology and Aquatic Ecology at the Ghent University in Belgium.These assays which were given the generic name “Toxkits”, are unique in that they employ dormant stages (“cryptobiotic eggs” of the test species, which can be stored for long periods of time and “hatched” at the time of

  19. Intermittent hypoxia reduces microglia proliferation and induces DNA damage in vitro

    Directory of Open Access Journals (Sweden)

    Song Liu

    2016-05-01

    Full Text Available Objective(s:Intermittent hypoxia (IH, caused by obstructive sleep apnea (OSA, could cause hippocampus or neuron damage through multiple signaling pathways, while the underlying mechanisms are still unclear. Thus, the present study aimed to explore the effect of IH on the biological functions of microglia cells. Materials and Methods:Cell proliferation of BV2 cells after exposure to IH were observed by MTT assay and then DNA damage was detected by comet assay. RNA-sequencing assay was performed in cells under IH condition and normal conditions to find out the differentially expressed genes, which were further confirmed by reverse transcriptase polymerase chain reaction (RT-PCR and Western blot assay. Results:As results, IH inhibited the proliferation of BV2 cells, as well as caused DNA damage. RNA-sequencing assay revealed 4 differentially expressed genes (p21, Cyclin D1, Cyclin E2, and Gadd45α which were associated with the network of P53 signaling pathways in BV2 cells, among which, p21 and Gadd45α were dramatically increased while Cyclin D1 and Cyclin E2 were both decreased significantly. Moreover, inflammatory factors including IL-6, TNF-α and iNOS were significantly up-regulated in microglia cells under IH conditions for 8 hr. Conclusion:Our results indicated that IH could inhibit cyclin D1 and cyclin E2 expression via initiating multiple P53 pathways, which further blocked cell cycle transition and attenuated proliferative capability of BV2 cells. Meanwhile, IH activated inflammation reactions in BV2 cells. Present study elaborate the effects of IH on biological functions of microglia and provide theoretical foundation for further study on new therapy methods for OSA.

  20. Analytic performance studies and clinical reproducibility of a real-time PCR assay for the detection of epidermal growth factor receptor gene mutations in formalin-fixed paraffin-embedded tissue specimens of non-small cell lung cancer

    International Nuclear Information System (INIS)

    O’Donnell, Patrick; Shieh, Felice; Wei, Wen; Lawrence, H Jeffrey; Wu, Lin; Schilling, Robert; Bloom, Kenneth; Maltzman, Warren; Anderson, Steven; Soviero, Stephen; Ferguson, Jane; Shyu, Johnny; Current, Robert; Rehage, Taraneh; Tsai, Julie; Christensen, Mari; Tran, Ha Bich; Chien, Sean Shih-Chang

    2013-01-01

    Epidermal growth factor receptor (EGFR) gene mutations identify patients with non-small cell lung cancer (NSCLC) who have a high likelihood of benefiting from treatment with anti-EGFR tyrosine kinase inhibitors. Sanger sequencing is widely used for mutation detection but can be technically challenging, resulting in longer turn-around-time, with limited sensitivity for low levels of mutations. This manuscript details the technical performance verification studies and external clinical reproducibility studies of the cobas EGFR Mutation Test, a rapid multiplex real-time PCR assay designed to detect 41 mutations in exons 18, 19, 20 and 21. The assay’s limit of detection was determined using 25 formalin-fixed paraffin-embedded tissue (FFPET)-derived and plasmid DNA blends. Assay performance for a panel of 201 specimens was compared against Sanger sequencing with resolution of discordant specimens by quantitative massively parallel pyrosequencing (MPP). Internal and external reproducibility was assessed using specimens tested in duplicate by different operators, using different reagent lots, instruments and at different sites. The effects on the performance of the cobas EGFR test of endogenous substances and nine therapeutic drugs were evaluated in ten FFPET specimens. Other tests included an evaluation of the effects of necrosis, micro-organisms and homologous DNA sequences on assay performance, and the inclusivity of the assay for less frequent mutations. A >95% hit rate was obtained in blends with >5% mutant alleles, as determined by MPP analysis, at a total DNA input of 150 ng. The overall percent agreement between Sanger sequencing and the cobas test was 96.7% (negative percent agreement 97.5%; positive percent agreement 95.8%). Assay repeatability was 98% when tested with two operators, instruments, and reagent lots. In the external reproducibility study, the agreement was > 99% across all sites, all operators and all reagent lots for 11/12 tumors tested. Test

  1. Performance characteristics of a reverse transcriptase-polymerase chain reaction assay for the detection of tumor-specific fusion transcripts from archival tissue.

    Science.gov (United States)

    Fritsch, Michael K; Bridge, Julia A; Schuster, Amy E; Perlman, Elizabeth J; Argani, Pedram

    2003-01-01

    Pediatric small round cell tumors still pose tremendous diagnostic problems. In difficult cases, the ability to detect tumor-specific gene fusion transcripts for several of these neoplasms, including Ewing sarcoma/peripheral primitive neuroectodermal tumor (ES/PNET), synovial sarcoma (SS), alveolar rhabdomyosarcoma (ARMS), and desmoplastic small round cell tumor (DSRCT) using reverse transcriptase-polymerase chain reaction (RT-PCR), can be extremely helpful. Few studies to date, however, have systematically examined several different tumor types for the presence of multiple different fusion transcripts in order to determine the specificity and sensitivity of the RT-PCR method, and no study has addressed this issue for formalin-fixed material. The objectives of this study were to address the specificity, sensitivity, and practicality of such an assay applied strictly to formalin-fixed tissue blocks. Our results demonstrate that, for these tumors, the overall sensitivity for detecting each fusion transcript is similar to that reported in the literature for RT-PCR on fresh or formalin-fixed tissues. The specificity of the assay is very high, being essentially 100% for each primer pair when interpreting the results from visual inspection of agarose gels. However, when these same agarose gels were examined using Southern blotting, a small number of tumors also yielded reproducibly detectable weak signals for unexpected fusion products, in addition to a strong signal for the expected fusion product. Fluorescence in situ hybridization (FISH) studies in one such case indicated that a rearrangement that would account for the unexpected fusion was not present, while another case was equivocal. The overall specificity for each primer pair used in this assay ranged from 94 to 100%. Therefore, RT-PCR using formalin-fixed paraffin-embedded tissue sections can be used to detect chimeric transcripts as a reliable, highly sensitive, and highly specific diagnostic assay. However, we

  2. Nuclear non-proliferation

    International Nuclear Information System (INIS)

    Anon.

    1990-01-01

    This patent describes the treaty on the non-proliferation of nuclear weapons which is the corner-stone of an international non-proliferation regime which has grown to embrace the overwhelming majority of countries in the world in the period since the Treaty. The other elements of the regime include, first of all, the safeguards system of IAEA-which operates to prevent the diversion of nuclear materials to military or other prohibited activities and must be accepted by all non-nuclear-weapon parties to the Treaty and, secondly, the Antarctic Treaty, the Treaty for the Prohibition of Nuclear Weapons in Latin America (Treaty of Tlatelolco) and the south Pacific Nuclear Free zone Treaty (Treaty of Rarotonga)-which serve to extend the regime geographically. The last two Treaties require safeguards agreements with IAEA. In addition, the Treaty of Tlatelolco contains provisions establishing the agency for the Prohibition of Nuclear Weapons in Latin America and the Caribbean to ensure compliance

  3. Proliferation in cycle

    Energy Technology Data Exchange (ETDEWEB)

    Piao Yunsong [College of Physical Sciences, Graduate School of Chinese Academy of Sciences, Beijing 100049 (China)], E-mail: yspiao@gucas.ac.cn

    2009-06-15

    In the contracting phase with w{approx_equal}0, the scale invariant spectrum of curvature perturbation is given by the increasing mode of metric perturbation. In this Letter, it is found that if the contracting phase with w{approx_equal}0 is included in each cycle of a cycle universe, since the metric perturbation is amplified on super horizon scale cycle by cycle, after each cycle the universe will be inevitably separated into many parts independent of one another, each of which corresponds to a new universe and evolves up to next cycle, and then is separated again. In this sense, a cyclic multiverse scenario is actually presented, in which the universe proliferates cycle by cycle. We estimate the number of new universes proliferated in each cycle, and discuss the implications of this result.

  4. Proliferation in cycle

    International Nuclear Information System (INIS)

    Piao Yunsong

    2009-01-01

    In the contracting phase with w≅0, the scale invariant spectrum of curvature perturbation is given by the increasing mode of metric perturbation. In this Letter, it is found that if the contracting phase with w≅0 is included in each cycle of a cycle universe, since the metric perturbation is amplified on super horizon scale cycle by cycle, after each cycle the universe will be inevitably separated into many parts independent of one another, each of which corresponds to a new universe and evolves up to next cycle, and then is separated again. In this sense, a cyclic multiverse scenario is actually presented, in which the universe proliferates cycle by cycle. We estimate the number of new universes proliferated in each cycle, and discuss the implications of this result.

  5. Maternal separation decreases adult hippocampal cell proliferation and impairs cognitive performance but has little effect on stress sensitivity and anxiety in adult Wistar rats.

    Science.gov (United States)

    Hulshof, Henriëtte J; Novati, Arianna; Sgoifo, Andrea; Luiten, Paul G M; den Boer, Johan A; Meerlo, Peter

    2011-01-20

    Stressful events during childhood are thought to increase the risk for the development of adult psychopathology. A widely used animal model for early life stress is maternal separation (MS), which is thought to affect development and cause alterations in neuroendocrine stress reactivity and emotionality lasting into adulthood. However, results obtained with this paradigm are inconsistent. Here we investigated whether this variation may be related to the type of stressor or the tests used to assess adult stress sensitivity and behavioral performance. Rat pups were exposed to a 3h daily MS protocol during postnatal weeks 1-2. In adulthood, animals were subjected to a wide variety of stressors and tests to obtain a better view on the effects of MS on adult hypothalamic-pituitary-adrenal (HPA) axis regulation, anxiety-like behavior, social interaction and cognition. Also, the influence of MS on adult hippocampal neurogenesis was studied because it might underlie changes in neuroendocrine regulation and behavioral performance. The results show that, independent of the nature of the stressor, MS did not affect the neuroendocrine response. MS did not influence anxiety-like behavior, explorative behavior and social interaction, but did affect cognitive function in an object recognition task. The amount of new born cells in the hippocampal dentate gyrus was significantly decreased in MS animals; yet, cell differentiation and survival were not altered. In conclusion, while interfering with the mother-infant relationship early in life did affect some aspects of adult neuroplasticity and cognitive function, it did not lead to permanent changes in stress sensitivity and emotionality. Copyright © 2010 Elsevier B.V. All rights reserved.

  6. MicroRNA-2400 promotes bovine preadipocyte proliferation

    International Nuclear Information System (INIS)

    Wei, Yao; Cui, Ya Feng; Tong, Hui Li; Zhang, Wei Wei; Yan, Yun Qin

    2016-01-01

    MicroRNAs (miRNAs) play critical roles in the proliferation of bovine preadipocytes. miR-2400 is a novel and unique miRNA from bovines. In the present study, we separated and identified preadipocytes from bovine samples. miR-2400 overexpression increased the rate of preadipocyte proliferation, which was analyzed with a combination of EdU and flow cytometry. Simultaneously, functional genes related to proliferation (PCNA, CCND2, CCNB1) were also increased, which was detected by real-time PCR. Furthermore, luciferase reporter assays showed that miR-2400 bound directly to the 3'untranslated regions (3′UTRs) of PRDM11 mRNA. These data suggested that miR-2400 could promote preadipocyte proliferation by targeting PRDM11. - Highlights: • miRNAs are important in bovine preadipocyte proliferation. • miR-2400 is a novel miRNA from bovines. • miR-2400 overexpression increased preadipocyte proliferation. • Functional genes related to preadipocyte proliferation were upregulated. • Preadipocyte proliferation was promoted by targeting PRDM11.

  7. Global proliferation concerns

    International Nuclear Information System (INIS)

    Simpkins, R.

    1978-01-01

    The Non-Proliferation Treaty and the IAGA Safeguards System are discussed. President Carter's program to defer commercial reprocessing and recycle, to restructure the breeder program, to develop alternative fuel cycles, to increase US uranium enrichment capability, to provide fuel assurance for consumer nations, to continue the embargo of sensitive technology and equipment and to develop the International Nuclear Fuel Cycle Evaluation Program is outlined

  8. Intermittent pressure decreases human keratinocyte proliferation in vitro.

    Science.gov (United States)

    Nasca, Maria R; Shih, Alan T; West, Dennis P; Martinez, Wanda M; Micali, Giuseppe; Landsman, Adam S

    2007-01-01

    The aim of this study was to investigate the correlation between pressure changes and keratinocyte proliferation by determining whether keratinocytes exposed to altered mechanical pressures would proliferate at different rates compared to control cells not subjected to pressure changes. Tissue culture flasks of human keratinocytes plated at an approximate density of 15,000 cells/cm(2) undergoing an intermittent cyclic pressure of 362 mm Hg at a frequency of 2.28 or 5.16 cycles/min (0.038 or 0.086 Hz) for 8 h were compared to control flasks grown at ambient room pressure. An in-line pressure transducer was used to monitor and adjust pressure within the cell chambers, using a solenoid valve. A thymidine incorporation assay assessed the amount of cell proliferation in each set of experiments. Differences in proliferation between keratinocytes subjected to cyclic pressure changes and control cells were found to be statistically significant (p < 0.05) in 4 out of 5 proliferation assays. Also, a higher frequency of pressure changes consistently generated a reduced proliferation rate compared to that seen in cells exposed to a lower frequency of pressure changes. These data indicate that keratinocytes undergoing intermittent pressure changes exhibit decreased proliferation rates compared to controls. Furthermore, an increased frequency rate seems to have a greater effect on proliferation than low-frequency rate pressure changes, suggesting that the stress caused by frequently changed pressure may play a greater role in reducing keratinocyte proliferation than the actual magnitude of load applied to the cells. Our results support the current treatment protocol of reducing speed and duration of walking on the site of the wound to promote healing of foot ulcers. (c) 2007 S. Karger AG, Basel.

  9. Chloroquinone Inhibits Cell Proliferation and Induces Apoptosis in ...

    African Journals Online (AJOL)

    Purpose: To demonstrate the role of chloroquinone (CQ) in inducing apoptosis in HONE-1 and HNE-1, nasopharyngeal carcinoma (NPC) cell lines. Methods: Water-soluble tetrazolium salt (WST)-1 assay was used for the determination of cell proliferation while an inverted microscope was employed for the analysis of ...

  10. Bryostatin I inhibits growth and proliferation of pancreatic cancer ...

    African Journals Online (AJOL)

    Purpose: To evaluate the effect of bryostatin I on proliferation of pancreatic cancer cells as well as tumor growth in mice tumor xenograft model. Methods: Activation of NF-κB was evaluated by preparing nuclear material extract using nuclear extract kit (Carlsbad, CA, USA) followed by enzyme-linked immunosorbent assay ...

  11. Inhibition of vascular smooth muscle cell proliferation by Gentiana lutea root extracts.

    Directory of Open Access Journals (Sweden)

    Rushendhiran Kesavan

    Full Text Available Gentiana lutea belonging to the Gentianaceae family of flowering plants are routinely used in traditional Serbian medicine for their beneficial gastro-intestinal and anti-inflammatory properties. The aim of the study was to determine whether aqueous root extracts of Gentiana lutea consisting of gentiopicroside, gentisin, bellidifolin-8-O-glucoside, demethylbellidifolin-8-O-glucoside, isovitexin, swertiamarin and amarogentin prevents proliferation of aortic smooth muscle cells in response to PDGF-BB. Cell proliferation and cell cycle analysis were performed based on alamar blue assay and propidium iodide labeling respectively. In primary cultures of rat aortic smooth muscle cells (RASMCs, PDGF-BB (20 ng/ml induced a two-fold increase in cell proliferation which was significantly blocked by the root extract (1 mg/ml. The root extract also prevented the S-phase entry of synchronized cells in response to PDGF. Furthermore, PDGF-BB induced ERK1/2 activation and consequent increase in cellular nitric oxide (NO levels were also blocked by the extract. These effects of extract were due to blockade of PDGF-BB induced expression of iNOS, cyclin D1 and proliferating cell nuclear antigen (PCNA. Docking analysis of the extract components on MEK1, the upstream ERK1/2 activating kinase using AutoDock4, indicated a likely binding of isovitexin to the inhibitor binding site of MEK1. Experiments performed with purified isovitexin demonstrated that it successfully blocks PDGF-induced ERK1/2 activation and proliferation of RASMCs in cell culture. Thus, Gentiana lutea can provide novel candidates for prevention and treatment of atherosclerosis.

  12. Inhibition of vascular smooth muscle cell proliferation by Gentiana lutea root extracts.

    Science.gov (United States)

    Kesavan, Rushendhiran; Potunuru, Uma Rani; Nastasijević, Branislav; T, Avaneesh; Joksić, Gordana; Dixit, Madhulika

    2013-01-01

    Gentiana lutea belonging to the Gentianaceae family of flowering plants are routinely used in traditional Serbian medicine for their beneficial gastro-intestinal and anti-inflammatory properties. The aim of the study was to determine whether aqueous root extracts of Gentiana lutea consisting of gentiopicroside, gentisin, bellidifolin-8-O-glucoside, demethylbellidifolin-8-O-glucoside, isovitexin, swertiamarin and amarogentin prevents proliferation of aortic smooth muscle cells in response to PDGF-BB. Cell proliferation and cell cycle analysis were performed based on alamar blue assay and propidium iodide labeling respectively. In primary cultures of rat aortic smooth muscle cells (RASMCs), PDGF-BB (20 ng/ml) induced a two-fold increase in cell proliferation which was significantly blocked by the root extract (1 mg/ml). The root extract also prevented the S-phase entry of synchronized cells in response to PDGF. Furthermore, PDGF-BB induced ERK1/2 activation and consequent increase in cellular nitric oxide (NO) levels were also blocked by the extract. These effects of extract were due to blockade of PDGF-BB induced expression of iNOS, cyclin D1 and proliferating cell nuclear antigen (PCNA). Docking analysis of the extract components on MEK1, the upstream ERK1/2 activating kinase using AutoDock4, indicated a likely binding of isovitexin to the inhibitor binding site of MEK1. Experiments performed with purified isovitexin demonstrated that it successfully blocks PDGF-induced ERK1/2 activation and proliferation of RASMCs in cell culture. Thus, Gentiana lutea can provide novel candidates for prevention and treatment of atherosclerosis.

  13. Proliferation after the Iraq war

    International Nuclear Information System (INIS)

    Daguzan, J.F.

    2004-09-01

    This article uses the Iraq war major event to analyze the approach used by the US to fight against proliferation. It questions the decision and analysis process which has led to the US-British intervention and analyzes the consequences of the war on the proliferation of other countries and on the expected perspectives. Finally, the future of proliferation itself is questioned: do we have to fear more threat or is the virtuous circle of non-proliferation well started? (J.S.)

  14. The role of Sep (O-phosphoserine) tRNA: Sec (selenocysteine) synthase (SEPSECS) in proliferation, apoptosis and hormone secretion of trophoblast cells.

    Science.gov (United States)

    Zhao, H-D; Zhang, W-G; Sun, M-N; Duan, Q-F; Li, F-L; Li, H

    2013-11-01

    To investigate whether Sep (O-phosphoserine) tRNA: Sec (selenocysteine) synthase (SEPSECS), which plays an essential role in the synthesis of selenoprotein, affects proliferation, apoptosis and hormone secretion of human trophoblast cells. Human trophoblast JEG-3 cells were divided into four groups: control group, SEPSECS silenced-expression group, empty vector group and SEPSECS over-expression group. Over-expression and silenced-expression were achieved by transfection with plasmid DNA or RNA oligonucleotide, respectively. 3-[4,5-dimethylthiazol-2-yl] -2,5-diphenyltetrazolium bromide (MTT) and colony formation assays were performed to investigate cell proliferation, while apoptosis was tested by annexin V-FITC, PI double staining and caspases-3 activation assays, enzyme-linked immunosorbent assay (ELISA) was used to determine the level of progesterone (PG) and human chorionic gonadotropin (hCG). SEPSECS silenced-expression clearly inhibited proliferation of JEG-3 cells (p < 0.05), significantly induced cell apoptosis (p < 0.01) and reduced the production of PG and hCG (p < 0.05). On the contrary, SEPSECS over-expression significantly promoted both cell proliferation (p < 0.01) and secretion of PG and hCG (p < 0.05). SEPSECS significantly affects proliferation, apoptosis and hormone secretion of human trophoblast cells, suggesting that a potential relationship exists among SEPSECS, cell proliferation, apoptosis and hormone production of human placental trophoblast cells. Furthermore, this may provide a clue to uncover the relationship between selenium and human placental in association with an emphasis on the importance of selenium adequacy during pregnancy. Copyright © 2013 Elsevier Ltd. All rights reserved.

  15. Incarvine C suppresses proliferation and vasculogenic mimicry of hepatocellular carcinoma cells via targeting ROCK inhibition

    International Nuclear Information System (INIS)

    Zhang, Ji-Gang; Zhang, Dan-Dan; Wu, Xin; Wang, Yu-Zhu; Gu, Sheng-Ying; Zhu, Guan-Hua; Li, Xiao-Yu; Li, Qin; Liu, Gao-Lin

    2015-01-01

    Studies have described vasculogenic mimicry (VM) as an alternative circulatory system to blood vessels in multiple malignant tumor types, including hepatocellular carcinoma (HCC). In the current study, we aimed to seek novel and more efficient treatment strategies by targeting VM and explore the underlying mechanisms in HCC cells. Cell counting kit-8 (CCK-8) assay and colony survival assay were performed to explore the inhibitory effect of incarvine C (IVC) on human cancer cell proliferation. Flow cytometry was performed to analyze the cell cycle distribution after DNA staining and cell apoptosis by the Annexin V-PE and 7-AAD assay. The effect of IVC on Rho-associated, coiled-coil-containing protein kinase (ROCK) was determined by western blotting and stress fiber formation assay. The inhibitory role of IVC on MHCC97H cell VM formation was determined by formation of tubular network structures on Matrigel in vitro, real time-qPCR, confocal microscopy and western blotting techniques. We explored an anti-metastatic HCC agent, IVC, derived from traditional Chinese medicinal herbs, and found that IVC dose-dependently inhibited the growth of MHCC97H cells. IVC induced MHCC97H cell cycle arrest at G1 transition, which was associated with cyclin-dependent kinase 2 (CDK-2)/cyclin-E1 degradation and p21/p53 up-regulation. In addition, IVC induced apoptotic death of MHCC97H cells. Furthermore, IVC strongly suppressed the phosphorylation of the ROCK substrate myosin phosphatase target subunit-1 (MYPT-1) and ROCK-mediated actin fiber formation. Finally, IVC inhibited cell-dominant tube formation in vitro, which was accompanied with the down-regulation of VM-key factors as detected by real time-qPCR and immunofluorescence. Taken together, the effective inhibitory effect of IVC on MHCC97H cell proliferation and neovascularization was associated with ROCK inhibition, suggesting that IVC may be a new potential drug candidate for the treatment of HCC

  16. Correlation between the genotoxicity endpoints measured by two different genotoxicity assays: comet assay and CBMN assay

    Directory of Open Access Journals (Sweden)

    Carina Ladeira

    2015-06-01

    The results concerning of positive findings by micronuclei and non significant ones by comet assay, are corroborated by Deng et al. (2005 study performed in workers occupationally exposed to methotrexate, also a cytostatic drug. According to Cavallo et al. (2009, the comet assay seems to be more suitable for the prompt evaluation of the genotoxic effects, for instance, of polycyclic aromatic hydrocarbons mixtures containing volatile substances, whereas the micronucleus test seems more appropriate to evaluate the effects of exposure to antineoplastic agents. However, there are studies that observed an increase in both the comet assay and the micronucleus test in nurses handling antineoplastic drugs, although statistical significance was only seen in the comet assay, quite the opposite of our results (Maluf & Erdtmann, 2000; Laffon et al. 2005.

  17. Performance of a Highly Sensitive Mycobacterium tuberculosis Complex Real-Time PCR Assay for Diagnosis of Pulmonary Tuberculosis in a Low-Prevalence Setting: a Prospective Intervention Study.

    Science.gov (United States)

    Vinuesa, Víctor; Borrás, Rafael; Briones, María Luisa; Clari, María Ángeles; Cresencio, Vicenta; Giménez, Estela; Muñoz, Carmen; Oltra, Rosa; Servera, Emilio; Scheelje, Talia; Tornero, Carlos; Navarro, David

    2018-05-01

    The potential impact of routine real-time PCR testing of respiratory specimens from patients with presumptive tuberculosis in terms of diagnostic accuracy and time to tuberculosis treatment inception in low-prevalence settings remains largely unexplored. We conducted a prospective intervention cohort study. Respiratory specimens from 1,020 patients were examined by acid-fast bacillus smear microscopy, tested by a real-time Mycobacterium tuberculosis complex PCR assay (Abbott RealTi me MTB PCR), and cultured in mycobacterial media. Seventeen patients tested positive by PCR (5 were acid-fast bacillus smear positive and 12 acid-fast bacillus smear negative), and Mycobacterium tuberculosis was recovered from cultures for 12 of them. Patients testing positive by PCR and negative by culture ( n = 5) were treated and deemed to have responded to antituberculosis therapy. There were no PCR-negative/culture-positive cases, and none of the patients testing positive for nontuberculous mycobacteria ( n = 20) yielded a positive PCR result. The data indicated that routine testing of respiratory specimens from patients with presumptive tuberculosis by the RealTi me MTB PCR assay improves the tuberculosis diagnostic yield and may reduce the time to antituberculosis treatment initiation. On the basis of our data, we propose a novel mycobacterial laboratory algorithm for tuberculosis diagnosis. Copyright © 2018 American Society for Microbiology.

  18. Development of a stability-indicating high performance liquid chromatography method for assay of erythromycin ethylsuccinate in powder for oral suspension dosage form

    Directory of Open Access Journals (Sweden)

    Fahimeh Kamarei

    2014-12-01

    Full Text Available In this study an effective method was developed to assay erythromycin ethylsuccinate for an oral suspension dosage form. The chromatographic separation was achieved on an X-Terra™ C18 analytical column. A mixture of acetonitrile–ammonium dihydrogen phosphate buffer (0.025 mol L-1 (60:40, V/V (pH 7.0 was used as the mobile phase, effluent flow rate monitored at 1.0 mL min−1, and UV detection at 205 nm. In forced degradation studies, the effects of acid, base, oxidation, UV light and temperature were investigated showing no interference in the peak of drug. The proposed method was validated in terms of specificity, linearity, robustness, precision and accuracy. The method was linear at concentrations ranging from 400 to 600 μg mL−1, precise (intra- and inter-day relative standard deviations <0.65, accurate (mean recovery; 99.5%. The impurities and degradation products of erythromycin ethylsuccinate were selectively determined with good resolution in both the raw material and the final suspension forms. The method could be useful for both routine analytical and quality control assays of erythromycin ethylsuccinate in commercial powder for an oral suspension dosage form and it could be a very powerful tool to investigate the chemical stability of erythromycin ethylsuccinate.

  19. Regulation of androgen receptor transactivity and mTOR-S6 kinase pathway by Rheb in prostate cancer cell proliferation.

    Science.gov (United States)

    Kobayashi, Takashi; Shimizu, Yosuke; Terada, Naoki; Yamasaki, Toshinari; Nakamura, Eijiro; Toda, Yoshinobu; Nishiyama, Hiroyuki; Kamoto, Toshiyuki; Ogawa, Osamu; Inoue, Takahiro

    2010-06-01

    Ras homolog-enriched in brain (Rheb), a small GTP-binding protein, is associated with prostate carcinogenesis through activating mammalian target of rapamycin (mTOR) signaling pathway. This study aimed to elucidate whether Rheb promotes proliferation of prostate cancer cells and can act as a potent therapeutic target in prostate cancer. Prostate cancer cell lines and human prostatic tissues were examined for the expression of Rheb. The effects of forced expression or knockdown of Rheb on cell proliferation were also examined. Semi-quantitative and quantitative RT-PCR were performed to evaluate mRNA expression. Western blotting was used to examine protein expression. Cell count and WST-1 assay were used to measure cell proliferation. Fluorescence-activated cell sorting was used to assess the cell cycle. Rheb mRNA and protein expression was higher in more aggressive, androgen-independent prostate cancer cell lines PC3, DU145, and C4-2, compared with the less aggressive LNCaP. Rheb expression was higher in cancer tissues than in benign prostatic epithelia. Forced expression of Rheb in LNCaP cells accelerated proliferation without enhancing androgen receptor transactivity. Attenuation of Rheb expression or treatment with the mTOR inhibitor rapamycin decreased proliferation of PC3 and DU145 cells, with a decrease in the activated form of p70S6 kinase, one of the main targets of mTOR. Rheb potentiates proliferation of prostate cancer cells and inhibition of Rheb or mTOR can lead to suppressed proliferation of aggressive prostate cancer cell lines in vitro. Rheb and the mTOR pathway are therefore probable targets for suppressing prostate cancer.

  20. Can we predict nuclear proliferation

    International Nuclear Information System (INIS)

    Tertrais, Bruno

    2011-01-01

    The author aims at improving nuclear proliferation prediction capacities, i.e. the capacities to identify countries susceptible to acquire nuclear weapons, to interpret sensitive activities, and to assess nuclear program modalities. He first proposes a retrospective assessment of counter-proliferation actions since 1945. Then, based on academic studies, he analyzes what causes and motivates proliferation, with notably the possibility of existence of a chain phenomenon (mechanisms driving from one program to another). He makes recommendations for a global approach to proliferation prediction, and proposes proliferation indices and indicators

  1. EL4 cell-based colorimetric toxin neutralization activity assays for determination of neutralizing anti-ricin antibodies.

    Science.gov (United States)

    Lindsey, Changhong Y; Brown, J Edward; Torabazar, Nahid R; Smith, Leonard A

    2013-01-01

    A recombinant ricin toxin A-chain 1-33/44-198 vaccine (RVEc), developed at the United States Army Medical Research Institute of Infectious Diseases as a vaccine candidate, is under investigation in a phase 1 clinical study. To effectively evaluate the immunogenicity of this ricin vaccine and to eliminate the use of radioactive material, an EL4 cell-based colorimetric toxin neutralization activity (TNA) assay using a CellTiter 96 AQueous One Solution Cell Proliferation Assay Reagent has been developed, optimized, and applied in the vaccine efficacy studies. The TNA assay measures the protective neutralizing anti-ricin antibodies in animal sera by determining the cell viability after ricin exposure in the assay system and comparing it to a purified mouse polyclonal antiricin IgG standard curve. The standard curve of the anti-ricin TNA assay closely fits a four-parameter logistic regression model. The unknown test sample concentration was expressed as microg/mL, but not the 50% effective concentration (EC50), which was determined by most TNA assays. The neutralizing endpoint titers, not the 50% effective dilution (ED50), of human specimens were measured with the TNA assay in support of the clinical study of the RVEc vaccine. The optimal amount of ricin toxin, EL4 cells, and concentration of standards used in the assay system was established to minimize false-negative and false-positive results of serum specimens from the nonclinical and clinical studies of RVEc. The testing conditions were adjusted to optimize assay performance. The colorimetric TNA assay replaced a radioactive TNA assay previously used in the ricin vaccine studies.

  2. Matrix effects of TRU [transuranic] assays using the SWEPP PAN assay system

    International Nuclear Information System (INIS)

    Smith, J.R.

    1990-08-01

    The Drum Assay System (DAS) at the Stored Waste Experimental Pilot Plant (SWEPP) is a second-generation active-passive neutron assay system. It has been used to assay over 5000 208-liter drums of transuranic waste from the Rocky Flats Plant (RFP). Data from these assays have been examined and compared with the assays performed at Rocky Flats, mainly utilize counting of 239 Pu gamma rays. For the most part the passive assays are in very good agreement with the Rocky Flats assays. The active assays are strongly correlated with the results of the other two methods, but require matrix-dependent correction factors beyond those provided by the system itself. A set of matrix-dependent correction factors has been developed from the study of the assay results. 3 refs., 4 figs., 3 tabs

  3. Performance of four different indirect enzyme-linked immunosorbent assays (ELISAs) to detect specific IgG, IgA, and IgM in Legionnaires' disease

    DEFF Research Database (Denmark)

    Bangsborg, Jette Marie; Shand, G H; Hansen, K

    1994-01-01

    Currently recommended methods in Legionnaires' disease serology are based upon crude whole-cell antigenic preparations. To investigate whether purified antigens would perform better in a given diagnostic test for antibodies against Legionella pneumophila, we compared the performance of three...

  4. Development and evaluation of the performance of a computer program for the quality control of radioligant assays, application to the radioassay of insulin

    International Nuclear Information System (INIS)

    Mesquita, C.H. de.

    1983-01-01

    A computer program was developed to evaluate several parameters of in radioligant assays. The program was written in FORTRAN-IV having a modular structure. The present version is designed to compute a number of parameters pertinent to the activities of the radioassays. The standard curve is fitted to the empirical model which has four parameters following Marquardt i-iterative scheme. The curve is weighted according to Rodbard criterion. The mini mum detectable dose (MDD) is estimated by a criterion which considers the standard deviation of the experimental data measured with respect to the zero concentration, theoretically computed by the power function. This function considers the standard deviations of all samples and standards being assayed. The Scatchard plot is drawn for one binding component, but it is suitable for up to five components including that nonspecific and non saturated one. The specific activity is computed by the self-displacement method including the corrections suggested by Morris. The computer program processes data pertinent to the thermodynamic analysis through the incubation temperature and its respective reaction affinity constant 'K'. Starting from the estimated enthalpy and entropy of the reaction, the program produces theoretical standard curves for any level of incubation temperature. This allows the analyst to select the interval which best attends the dosage needs. Other general data pertinent to the radioisotope methodology can also be processed by the present program, such as radiochromatogram analysis chi-square test and the estimate the error during the procedures of pipetting. In order to demonstrate the use and the quality of the informations given by the program, a radioimmunoassay of insulin was carried out. The results obtained are in good agreement with those found in the literature. (Author) [pt

  5. Dual repressive effect of angiotensin II-type 1 receptor blocker telmisartan on angiotensin II-induced and estradiol-induced uterine leiomyoma cell proliferation.

    Science.gov (United States)

    Isobe, Aki; Takeda, Takashi; Sakata, Masahiro; Miyake, Asako; Yamamoto, Toshiya; Minekawa, Ryoko; Nishimoto, Fumihito; Oskamoto, Yoko; Walker, Cheryl Lyn; Kimura, Tadashi

    2008-02-01

    Although uterine leiomyomas or fibroids are the most common gynecological benign tumor and greatly affect reproductive health and well-being, the pathophysiology and epidemiology of uterine leiomyomas are poorly understood. Elevated blood pressure has an independent, positive association with risk for clinically detected uterine leiomyoma. Angiotensin II (Ang II) is a key biological peptide in the renin-angiotensin system that regulates blood pressure. In this study, we investigated the potential role of Ang II (1-1000 nM) in the proliferation of rat ELT-3 leiomyoma cells in vitro. RT-PCR and western blot analysis with cell proliferation and DNA transfection assays were performed to determine the mechanism of action of Ang II. Ang II induced ELT-3 leiomyoma cell proliferation (P estradiol-induced cell proliferation (P < 0.01). AT(1)R, but not AT(2)R, plays a role in Ang II-induced ELT-3 cell proliferation. These experimental findings in vitro highlight the potential role of Ang II in the proliferation of leiomyoma cells.

  6. MiR-138 promotes smooth muscle cells proliferation and migration in db/db mice through down-regulation of SIRT1

    Energy Technology Data Exchange (ETDEWEB)

    Xu, Juan [Department of Gynecology, Changzhou Maternity and Children Health Hospital, Changzhou, Jiangsu 213003 (China); Li, Li; Yun, Hui-fang [Department of Anesthesiology, Changzhou No. 2 People' s Hospital, Changzhou, Jiangsu 213003 (China); Han, Ye-shan, E-mail: yeshanhan123@163.com [Department of Anesthesiology, Changzhou No. 2 People' s Hospital, Changzhou, Jiangsu 213003 (China)

    2015-08-07

    Background: Diabetic vascular smooth muscle cells (VSMCs) exhibit significantly increased rates of proliferation and migration, which was the most common pathological change in atherosclerosis. In addition, the study about the role for miRNAs in the regulation of VSMC proliferation is just beginning to emerge and additional miRNAs involved in VSMC proliferation modulation should be identified. Methods: The expression of miR-138 and SIRT1 were examined in SMCs separated from db/db mice and in SMC lines C-12511 exposed to high glucose with qRT-PCR and western blot. The regulation of miR-138 on the expression of SMCs was detected with luciferase report assay. VSMCs proliferation and migration assays were performed to examine the effect of miR-138 inhibitor on VSMCs proliferation and migration. Results: We discovered that higher mRNA level of miR-138 and reduced expression of SIRT1 were observed in SMCs separated from db/db mice and in SMC lines C-12511. Moreover, luciferase report assay showed that the activity of SIRT1 3′-UTR was highly increased by miR-138 inhibitor and reduced by miR-138 mimic. In addition, we examined that the up-regulation of NF-κB induced by high glucose in SMCs was reversed by resveratrol and miR-138 inhibitor. MTT and migration assays showed that miR-138 inhibitor attenuated the proliferation and migration of smooth muscle cells. Conclusion: In this study, we revealed that miR-138 might promote proliferation and migration of SMC in db/db mice through suppressing the expression of SIRT1. - Highlights: • Higher mRNA level of miR-138 was observed in SMCs from db/db mice. • The mRNA and protein level of SIRT1 in SMCs from db/db mice were greatly reduced. • miR-138 could regulate the expression of SIRT1 in SMCs. • SIRT1 overexpression reversed the up-regulation of acetylized p65 and NF-κB induced by high glucose. • MiR-138 inhibitor reversed VSMCs proliferation and migration induced by high glucose.

  7. Non-proliferation

    International Nuclear Information System (INIS)

    Deiseroth, D.; Gustafsson, S.

    1993-01-01

    The issue of Nuclear Non Proliferation has been moved to a leading place on the contemporary international security agenda. What about the situation of nuclear weapons and nuclear technology in Russia, Kazakhstan, Ukraine and Belorussia? Why did the IAEA-inspectors totally failed to discover any sign of Iraq's clandestine nuclear-weapon programme before the Gulf War? Do the NATO and their nuclear power states violate Art. VI of the Non-Proliferation-Treaty (NPT), because they are - despite the end of the cold war - not willing to renounce of the ''option of the first use of nuclear weapons''? Does the NPT establish a form of nuclear apartheid? What will be the situation if the NPT-Extension-Conference in 1995 will be unable to obtain a majority of the parties for any one extension proposal? Do we need a new international nuclear control agency with severe powers, a sort of nuclear Interpol? The Colloquium ''Saving NPT and abolishing Nuclear Weapons'', held in Stockholm in September 1992, organized by the Swedish and the German Sections of IALANA, tried to analyse some of the raised issues. (orig.) [de

  8. Non Proliferation of Nuclear

    International Nuclear Information System (INIS)

    Bambang S Irawan

    2004-01-01

    Non-Proliferation Treaty of Nuclear Weapons is the international community's efforts to maintain the security of the world, in order to prevent the spread of nuclear technology and the use of nuclear weapons, promoting cooperation for the use of nuclear peaceful purposes, build mutual trust (Confidence Building Measures) as well as to achieve the ultimate goal of disarmament overall (General and Complete Disarmament). Addressing the post-WTC tragedy, 11 September 2001, the Indonesian government should set up a National Measures (National Action Plan), among others formed the National Security Council and NBC Counter Proliferation Unit, or the National Authority for Nuclear Treaty, preparing national legislation, to prevent the abuse nuclear materials for terrorist acts, prevent Illicit Trafficking of Nuclear materials, developed a National Preparedness and Emergency Response Management in the event of a nuclear accident or attack by the use of nuclear terrorism. Importance of a National Action Plan meant the existence of a national commitment in the context of compliance with treaties and conventions which have been ratified relating to safety, security, safeguards towards a general and complete disarmament, to safeguard national security and maintain peace (safeguards) international

  9. Initiatives for proliferation prevention

    International Nuclear Information System (INIS)

    1997-04-01

    Preventing the proliferation of weapons of mass destruction is a central part of US national security policy. A principal instrument of the Department of Energy's (DOE's) program for securing weapons of mass destruction technology and expertise and removing incentives for scientists, engineers and technicians in the newly independent states (NIS) of the former Soviet Union to go to rogue countries or assist terrorist groups is the Initiatives for Proliferation Prevention (IPP). IPP was initiated pursuant to the 1994 Foreign Operations Appropriations Act. IPP is a nonproliferation program with a commercialization strategy. IPP seeks to enhance US national security and to achieve nonproliferation objectives by engaging scientists, engineers and technicians from former NIS weapons institutes; redirecting their activities in cooperatively-developed, commercially viable non-weapons related projects. These projects lead to commercial and economic benefits for both the NIS and the US IPP projects are funded in Russian, Ukraine, Kazakhstan and Belarus. This booklet offers an overview of the IPP program as well as a sampling of some of the projects which are currently underway

  10. Asiaticoside induces cell proliferation and collagen synthesis in human dermal fibroblasts

    Directory of Open Access Journals (Sweden)

    Linda Yulianti

    2015-08-01

    Full Text Available Asiatiocoside, a saponin component isolated from Centella asiatica can improve wound healing by promoting the proliferation of human dermal fibroblasts (HDF and synthesis of collagen. The skin-renewing cells and type I and III collagen synthesis decrease with aging, resulting in the reduction of skin elasticity and delayed wound healing. Usage of natural active compounds from plants in wound healing should be evaluated and compared to retinoic acid as an active agent that regulates wound healing. The aim of this study was to compare and evaluate the effect of asiaticoside and retinoic acid to induce greater cell proliferation and type I and III collagen synthesis in human dermal fibroblast. Methods Laboratory experiments were conducted using human dermal fibroblasts (HDF isolated from human foreskin explants. Seven passages of HDF were treated with asiaticoside and retinoic acid at several doses and incubated for 24 and 48 hours. Cell viability in all groups was tested with the MTT assay to assess HDF proliferation. Type I and III collagen synthesis was examined using the respective ELISA kits. Analysis of variance was performed to compare the treatment groups. Results Asiaticoside had significantly stronger effects on HDF proliferation than retinoic acid (p<0.05. The type III collagen production was significantly greater induction with asiaticoside compared to retinoic acid (p<0.05. Conclusion Asiaticoside induces HDF proliferation and type I and III collagen synthesis in a time- and dose-dependent pattern. Asiaticoside has a similar effect as retinoic acid on type I and type III collagen synthesis.

  11. Hematopoietic Substrate-1-Associated Protein X-1 Regulates the Proliferation and Apoptosis of Endothelial Progenitor Cells Through Akt Pathway Modulation.

    Science.gov (United States)

    Guo, Xin-Bin; Deng, Xin; Wei, Ying

    2018-03-01

    Endothelial precursor cells (EPCs) are involved in vasculogenesis of various physiological and pathological processes. The proliferation and survival mechanism of EPCs needs to be explored further for the purpose of developing an effective glioma treatment. Hematopoietic substrate-1-associated protein X-1 (HAX-1) has been reported as an anti-apoptotic protein that plays an important role in several malignant tumors. However, the effect and mechanism of HAX-1 on EPCs remains unknown. This study aims to investigate the effect of HAX-1 on the proliferation and apoptosis of EPCs and explore its mechanism. According to our results, HAX-1 was overexpressed in EPCs. The results of clone formation and 5-ethynyl-2'-deoxyuridine proliferation assay showed that HAX-1 promoted multiplication of EPCs. Flow cytometry showed HAX-1 knockout cell cycle arrest mainly in G0/G1 phase. Apoptosis analysis showed that HAX-1 could protect EPCs from apoptosis in oxidative stress. Western blot assay indicated that HAX-1 could inhibit the activation of caspase cascade and reduce the expression of p21, Bcl-2-associated X protein, and p53. HAX-1 also enhanced the degradation rate and ubiquitination of p53 through the promotion of phosphorylation of proteins MDM-2 and Akt1. Co-immunoprecipitation and immunofluorescent colocalization assays were performed to test the influence of HAX-1 on the interaction between Akt1 and heat shock protein 90 (Hsp90), which is crucial for the activity of Akt1. In conclusion, this novel study suggests that HAX-1 could facilitate the Akt1 pathway through Hsp90, which led to a decline in the levels of p53, and finally promoted the proliferation and inhibited the apoptosis of EPCs. Stem Cells 2018;36:406-419. © 2017 AlphaMed Press.

  12. Essential oil of Pinus koraiensis inhibits cell proliferation and migration via inhibition of p21-activated kinase 1 pathway in HCT116 colorectal cancer cells.

    Science.gov (United States)

    Cho, Sun-Mi; Lee, Eun-Ok; Kim, Sung-Hoon; Lee, Hyo-Jeong

    2014-07-30

    The essential oil of Pinus koraiensis (EOPK) is biologically active compound obtained from the leaves of P. koraiensis. The goal of this study was to investigate the anti-cancer mechanism of EOPK in HCT116 colorectal cancer cells. HCT116 cell proliferation was assessed by conducting crystal violet and BrdU assays. To assess the effects of EOPK on cell migration, we performed a wound-healing assay. Further, the contribution of PAK1 to EOPK-induced AKT and extracellular signal-regulated kinase (ERK) suppression was assessed by siRNA-mediated PAK1 knockdown. Changes to the expression and phosphorylation of PAK1 and its effectors were determined by western blotting, and changes to the actin cytoskeleton were determined by performing an immunofluorescence assay. EOPK significantly decreased HCT116 cell proliferation and migration, and induced G1 arrest without affecting normal cells. Additionally, EOPK suppressed the expression of PAK1, and decreased ERK and AKT phosphorylation in HCT116 cells. Finally, EOPK suppressed β-catenin, cyclin D1, and CDK4/6 expression. Our studies indicate that EOPK significantly reduced proliferation and migration of colorectal cancer cells. Furthermore, EOPK suppressed PAK1 expression in a dose-dependent manner, and this suppression of PAK1 led to inhibition of ERK, AKT, and β-catenin activities. Our findings suggest that EOPK exerts its anticancer activity via the inhibition of PAK1 expression, suggesting it may be a potent chemotherapeutic agent for colorectal cancer.

  13. Albumin Suppresses Human Hepatocellular Carcinoma Proliferation and the Cell Cycle

    Directory of Open Access Journals (Sweden)

    Shunsuke Nojiri

    2014-03-01

    Full Text Available Many investigations have revealed that a low recurrence rate of hepatocellular carcinoma (HCC is associated with high serum albumin levels in patients; therefore, high levels of serum albumin are a major indicator of a favorable prognosis. However, the mechanism inhibiting the proliferation of HCC has not yet been elucidated, so we investigated the effect of serum albumin on HCC cell proliferation. Hep3B was cultured in MEM with no serum or containing 5 g/dL human albumin. As control samples, Prionex was added to generate the same osmotic pressure as albumin. After 24-h incubation, the expressions of α-fetoprotein (AFP, p53, p21, and p57 were evaluated with real-time PCR using total RNA extracted from the liver. Protein expressions and the phosphorylation of Rb (retinoblastoma were determined by Western blot analysis using total protein extracted from the liver. For flow cytometric analysis of the cell cycle, FACS analysis was performed. The percentages of cell cycle distribution were evaluated by PI staining, and all samples were analyzed employing FACScalibur (BD with appropriate software (ModFit LT; BD. The cell proliferation assay was performed by counting cells with using a Scepter handy automated cell counter (Millipore. The mRNA levels of AFP relative to Alb(−: Alb(−, Alb(+, and Prionex, were 1, 0.7 ± 0.2 (p < 0.001 for Alb(−, and 1 ± 0.3, respectively. The mRNA levels of p21 were 1, 1.58 ± 0.4 (p = 0.007 for Alb(− and p = 0.004 for Prionex, and 0.8 ± 0.2, respectively. The mRNA levels of p57 were 1, 4.4 ± 1.4 (p = 0.002 for Alb(− and Prionex, and 1.0 ± 0.1, respectively. The protein expression levels of Rb were similar in all culture media. The phosphorylation of P807/811 and P780 of Rb protein was reduced in Alb(+. More cells in the G0/G1 phase and fewer cells in S and G2/M phases were obtained in Alb(+ than in Alb(− (G0/G1: 60.9%, 67.7%, 61.5%; G2/M: 16.5%, 13.1%, 15.6%; S: 22.6%, 19.2%, 23.0%, Alb(−, Alb

  14. Uncertainties in Nuclear Proliferation Modeling

    International Nuclear Information System (INIS)

    Kim, Chul Min; Yim, Man-Sung; Park, Hyeon Seok

    2015-01-01

    There have been various efforts in the research community to understand the determinants of nuclear proliferation and develop quantitative tools to predict nuclear proliferation events. Such systematic approaches have shown the possibility to provide warning for the international community to prevent nuclear proliferation activities. However, there are still large debates for the robustness of the actual effect of determinants and projection results. Some studies have shown that several factors can cause uncertainties in previous quantitative nuclear proliferation modeling works. This paper analyzes the uncertainties in the past approaches and suggests future works in the view of proliferation history, analysis methods, and variable selection. The research community still lacks the knowledge for the source of uncertainty in current models. Fundamental problems in modeling will remain even other advanced modeling method is developed. Before starting to develop fancy model based on the time dependent proliferation determinants' hypothesis, using graph theory, etc., it is important to analyze the uncertainty of current model to solve the fundamental problems of nuclear proliferation modeling. The uncertainty from different proliferation history coding is small. Serious problems are from limited analysis methods and correlation among the variables. Problems in regression analysis and survival analysis cause huge uncertainties when using the same dataset, which decreases the robustness of the result. Inaccurate variables for nuclear proliferation also increase the uncertainty. To overcome these problems, further quantitative research should focus on analyzing the knowledge suggested on the qualitative nuclear proliferation studies

  15. Proliferation: myth or reality?; La proliferation: mythe ou realite?

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2005-07-01

    This article analyzes the proliferation approach, its technical condition and political motivation, and the share between the myth (political deception, assumptions and extrapolations) and the reality of proliferation. Its appreciation is complicated by the irrational behaviour of some political actors and by the significant loss of the non-use taboo. The control of technologies is an important element for proliferation slowing down but an efficient and autonomous intelligence system remains indispensable. (J.S.)

  16. Effects of hydroxyapatite nanoparticles on proliferation and apoptosis of human breast cancer cells (MCF-7)

    International Nuclear Information System (INIS)

    Meena, Ramovatar; Kesari, Kavindra Kumar; Rani, Madhu; Paulraj, R.

    2012-01-01

    The study aimed to correlate cell proliferation inhibition with oxidative stress and p53 protein expression in cancerous cells. Hydroxyapatite (HAP) (Ca 10 (PO 4 ) 6 (OH) 2 ) is the essential component of inorganic composition in human bone. It has been found to have obvious inhibitory function on growth of many kinds of tumor cells and its nanoparticle has stronger anti-cancerous effect than macromolecule microparticles. Human breast cancer cells (MCF-7) were cultured and treated with HAP nanoparticles at various concentrations. Cells viability was detected with MTT colorimetric assay. The morphology of the cancerous cells was performed by transmission electron microscopy and the expression of a cell apoptosis related gene (p53) was determined by ELISA assay and flow cytometry (FCM). The intracellular reactive oxygen species (ROS) level in HAP exposed cells was measured by H 2 DCFDA staining. DNA damage was measured by single-cell gel electrophoresis assay. The statistical analysis was done by one way ANOVA. The cellular proliferation inhibition rate was significantly (p < 0.05) increasing in a dose-dependent manner of HAP nanoparticles. Cell apoptotic characters were observed after MCF-7 cells were treated by HAP nanoparticles for 48 h. Moreover, ELISA assay and FCM shows a dose-dependent activation of p53 in MCF-7 cells treated with nanoHAP. These causative factors of the above results may be justified by an overproduction of ROS. In this study, a significant (p < 0.05) increase in the level of intracellular ROS in HAP-treated cells was observed. This study shows that HAP inhibits the growth of human breast cancer MCF-7 cells as well as induces cell apoptosis. This study shows that HAP NPs Induce the production of intracellular reactive oxygen species and activate p53, which may be responsible for DNA damage and cell apoptosis.

  17. The Effect of Primary Cancer Cell Culture Models on the Results of Drug Chemosensitivity Assays: The Application of Perfusion Microbioreactor System as Cell Culture Vessel

    Science.gov (United States)

    Chen, Yi-Dao; Huang, Shiang-Fu; Wang, Hung-Ming

    2015-01-01

    To precisely and faithfully perform cell-based drug chemosensitivity assays, a well-defined and biologically relevant culture condition is required. For the former, a perfusion microbioreactor system capable of providing a stable culture condition was adopted. For the latter, however, little is known about the impact of culture models on the physiology and chemosensitivity assay results of primary oral cavity cancer cells. To address the issues, experiments were performed. Results showed that minor environmental pH change could significantly affect the metabolic activity of cells, demonstrating the importance of stable culture condition for such assays. Moreover, the culture models could also significantly influence the metabolic activity and proliferation of cells. Furthermore, the choice of culture models might lead to different outcomes of chemosensitivity assays. Compared with the similar test based on tumor-level assays, the spheroid model could overestimate the drug resistance of cells to cisplatin, whereas the 2D and 3D culture models might overestimate the chemosensitivity of cells to such anticancer drug. In this study, the 3D culture models with same cell density as that in tumor samples showed comparable chemosensitivity assay results as the tumor-level assays. Overall, this study has provided some fundamental information for establishing a precise and faithful drug chemosensitivity assay. PMID:25654105

  18. The nuclear proliferation

    International Nuclear Information System (INIS)

    Gere, F.

    1995-04-01

    In this book is detailed the beginning of nuclear military power, with the first bomb of Hiroshima, the different ways of getting uranium 235 and plutonium 239, and how the first countries (Usa, Ussr, China, United kingdom, France) got nuclear weapons. Then the most important part is reviewed with the details of non-proliferation treaty and the creation of IAEA to promote civilian nuclear power in the world and to control the use of plutonium and uranium in nuclear power plants. The cases of countries who reached the atom mastery, such Israel, South Africa, Pakistan, Iraq, North Korea, Argentina, Brazil, Iran, Algeria, Taiwan and the reasons which they wanted nuclear weapon for or why they gave up, are exposed

  19. Simultaneous detection of five different 2-hydroxyethyl-DNA adducts formed by ethylene oxide exposure, using a high-performance liquid chromatography/electrospray ionisation tandem mass spectrometry assay.

    Science.gov (United States)

    Tompkins, Elaine M; Jones, Donald J L; Lamb, John H; Marsden, Debbie A; Farmer, Peter B; Brown, Karen

    2008-01-01

    A method has been developed for the simultaneous detection and quantitation of five different 2-hydroxyethyl-DNA (HE-DNA) adducts that could be formed as a result of exposure to ethylene oxide (EO). In addition to the major N7-HE-guanine (N7-HEG) adducts this assay can also measure the less prevalent but potentially more biologically significant N1-HE-2'-deoxyadenosine (N1-HEdA), O(6)-HE-2'-deoxyguanosine (O(6)-HEdG), N(6)-HE-2'-deoxyadenosine (N(6)-HEdA) and N3-HE-2'-deoxyuridine adducts (N3-HEdU). The method involves the isolation of HE adducts from the unmodified nucleosides by either neutral thermal hydrolysis or enzymatic digestion, followed by high-performance liquid chromatographic (HPLC) purification, before detection and quantification by liquid chromatography tandem mass spectrometry (LC/MS/MS) using selective reaction monitoring (SRM). The limits of detection were in the range 0.5-25 fmol for each individual adduct, making this one of the most sensitive assays available for the detection of N7-HEG. To illustrate the possible applications of the assay, it has been employed in the measurement of endogenous/background and EO-induced HE adducts in a variety of DNA samples.

  20. MicroRNA-21 Increases Proliferation and Cisplatin Sensitivity of Osteosarcoma-Derived Cells.

    Directory of Open Access Journals (Sweden)

    Vanita Vanas

    Full Text Available Osteosarcoma is the most common primary bone tumor and poor prognosis for osteosarcoma patients is mainly due to chemotherapy resistance. MicroRNAs are important to maintain pathophysiological mechanisms of cancer and influence cell sensitivity to chemotherapy. In this study, we tested the functions of microRNA-21 for malignant features as well as for drug resistance of osteosarcoma. We used Northern blot to measure microRNA-21 levels in osteosarcoma-derived cell lines. MicroRNA-21 activity was modulated by either expressing a sponge to decrease its activity in an osteosarcoma-derived cell line expressing high levels of microRNA-21 or by introducing pri-microRNA-21 in a cell line with low endogenous levels. Cell migration was determined in a scratch assay and cell proliferation was measured by performing growth curve analysis. Sensitivity of the cells towards chemotherapeutics was investigated by performing cell viability assays and calculating the IC50 values. While cell migration was unaffected by modulated microRNA-21 levels, microRNA-21 inhibition slowed proliferation and exogenously expressed microRNA-21 promoted this process. Modulated microRNA-21 activity failed to effect sensitivity of osteosarcoma-derived cell lines to doxorubicin or methotrexate. Contrarily, reduction of microRNA-21 activity resulted in enhanced resistance towards cisplatin while ectopic expression of microRNA-21 showed the opposite effect. Increased microRNA-21 levels repressed the expression of Sprouty2 and ectopic expression of Sprouty2 was able to largely rescue the observed effects of microRNA-21 in osteosarcoma. In summary, our data indicate that in osteosarcoma microRNA-21 expression is an important component for regulation of cell proliferation and for determining sensitivity to cisplatin.

  1. Microbead agglutination based assays

    KAUST Repository

    Kodzius, Rimantas

    2013-01-21

    We report a simple and rapid room temperature assay for point-of-care (POC) testing that is based on specific agglutination. Agglutination tests are based on aggregation of microbeads in the presence of a specific analyte thus enabling the macroscopic observation. Such tests are most often used to explore antibody-antigen reactions. Agglutination has been used for protein assays using a biotin/streptavidin system as well as a hybridization based assay. The agglutination systems are prone to selftermination of the linking analyte, prone to active site saturation and loss of agglomeration at high analyte concentrations. We investigated the molecular target/ligand interaction, explaining the common agglutination problems related to analyte self-termination, linkage of the analyte to the same bead instead of different microbeads. We classified the agglutination process into three kinds of assays: a two- component assay, a three-component assay and a stepped three- component assay. Although we compared these three kinds of assays for recognizing DNA and protein molecules, the assay can be used for virtually any molecule, including ions and metabolites. In total, the optimized assay permits detecting analytes with high sensitivity in a short time, 5 min, at room temperature. Such a system is appropriate for POC testing.

  2. Assay optimization for molecular detection of Zika virus

    NARCIS (Netherlands)

    Corman, Victor M.; Rasche, Andrea; Baronti, Cecile; Aldabbagh, Souhaib; Cadar, Daniel; Reusken, Chantal Bem; Pas, Suzan D.; Goorhuis, Abraham; Schinkel, Janke; Molenkamp, Richard; Kümmerer, Beate M.; Bleicker, Tobias; Brünink, Sebastian; Eschbach-Bludau, Monika; Eis-Hübinger, Anna M.; Koopmans, Marion P.; Schmidt-Chanasit, Jonas; Grobusch, Martin P.; de Lamballerie, Xavier; Drosten, Christian; Drexler, Jan Felix

    2016-01-01

    To examine the diagnostic performance of real-time reverse transcription (RT)-polymerase chain reaction (PCR) assays for Zika virus detection. We compared seven published real-time RT-PCR assays and two new assays that we have developed. To determine the analytical sensitivity of each assay, we

  3. Evaluation of the performance of Abbott m2000 and Roche COBAS Ampliprep/COBAS Taqman assays for HIV-1 viral load determination using dried blood spots and dried plasma spots in Kenya.

    Science.gov (United States)

    Zeh, Clement; Ndiege, Kenneth; Inzaule, Seth; Achieng, Rebecca; Williamson, John; Chih-Wei Chang, Joy; Ellenberger, Dennis; Nkengasong, John

    2017-01-01

    Routine HIV viral load testing is not widely accessible in most resource-limited settings, including Kenya. To increase access to viral load testing, alternative sample types like dried blood spots (DBS), which overcome the logistic barriers associated with plasma separation and cold chain shipment need to be considered and evaluated. The current study evaluated matched dried blood spots (DBS) and dried plasma spots (DPS) against plasma using the Abbott M 2000 (Abbott) and Roche Cobas Ampliprep/Cobas TaqMan (CAP/CTM) quantitative viral load assays in western Kenya. Matched plasma DBS and DPS were obtained from 200 HIV-1 infected antiretroviral treatment (ART)-experienced patients attending patient support centers in Western Kenya. Standard quantitative assay performance parameters with accompanying 95% confidence intervals (CI) were assessed at the assays lower detection limit (400cps/ml for CAP/CTM and 550cps/ml for Abbott) using SAS version 9.2. Receiver operating curves (ROC) were further used to assess viral-load thresholds with best assay performance (reference assay CAP/CTM plasma). Using the Abbott test, the sensitivity and specificity, respectively, for DPS were (97.3%, [95%CI: 93.2-99.2] and 98.1% [95%CI: 89.7-100]) and those for DBS (93.9% [95%CI: 88.8-97.2] and 88.0% [95%CI: 82.2-92.4]). The correlation and agreement using paired plasma and DPS/DBS were strong, with r2 = 90.5 and rc = 68.1. The Bland-Altman relative percent change was 95.3 for DPS, (95%CI: 90.4-97.7) and 73.6 (95%CI: 51.6-86.5) for DBS. Using the CAP/CTM assay, the sensitivity for DBS was significantly higher compared to DPS (100.0% [95% CI: 97.6-100.0] vs. 94.7% [95%CI: 89.8-97.7]), while the specificity for DBS was lower: 4%, [95% CI: 0.4-13.7] compared to DPS: 94.0%, [95% CI: 83.5-98.7]. When compared under different clinical relevant thresholds, the accuracy for the Abbott assay was 95% at the 1000cps/ml cut-off with a sensitivity and specificity of 96.6% [95% CI 91.8-98.7] and 90

  4. Nicotine promotes proliferation and collagen synthesis of chondrocytes isolated from normal human and osteoarthritis patients.

    Science.gov (United States)

    Ying, Xiaozhou; Cheng, Shaowen; Shen, Yue; Cheng, Xiaojie; An Rompis, Ferdinand; Wang, Wei; Lin, Zhongqin; Chen, Qingyu; Zhang, Wei; Kou, Dongquan; Peng, Lei; Tian, Xin Qiao; Lu, Chuan Zhu

    2012-01-01

    The aims of the study were to show the direct effect of nicotine with different concentrations (0, 25, 50, and 100 ng/ml) on chondrocytes isolated from normal human and osteoarthritis patients, respectively. Microscopic observation was performed during the culture with an inverted microscope. Methyl thiazolyl tetrazolium (MTT) assay method was adopted to observe the influence of nicotine on the proliferation of chondrocytes, and real-time PCR and ELISA were used to assay the mRNA and protein expression of type II collagen and aggrecan, respectively. We discovered that the OA chondrocytes were similar to fibroblasts in shape and grow slower than normal chondrocytes. The proliferation of the two kinds of chondrocytes was increased in a concentration-dependent manner and in a time-dependent manner (P<0.05). Also, we found that the mRNA level of type II collagen were upregulated under 25-100 ng/ml nicotine doses both in the two kinds of chondrocytes compared with control. The expression of protein levels of type II collagen were synthesized in line with the increase in mRNA. No effect was observed on aggrecan synthesis with any nicotine dose. We concluded that nicotine has the same effect on both chondrocytes, obtained either from osteoarthritis patients or from normal human, and the positive effect of smoking in OA may relate to the alteration in metabolism of chondrocytes.

  5. Radioreceptor opioid assay

    International Nuclear Information System (INIS)

    Miller, R.J.; Chang, K.-J.

    1981-01-01

    A radioreceptor assay is described for assaying opioid drugs in biological fluids. The method enables the assay of total opioid activity, being specific for opioids as a class but lacking specificity within the class. A radio-iodinated opioid and the liquid test sample are incubated with an opiate receptor material. The percentage inhibition of the binding of the radio-iodinated compound to the opiate receptor is calculated and the opioid activity of the test liquid determined from a standard curve. Examples of preparing radio-iodinated opioids and assaying opioid activity are given. A test kit for the assay is described. Compared to other methods, this assay is cheap, easy and rapid. (U.K.)

  6. The Lncrna-TUG1/EZH2 Axis Promotes Pancreatic Cancer Cell Proliferation, Migration and EMT Phenotype Formation Through Sponging Mir-382.

    Science.gov (United States)

    Zhao, Liang; Sun, Hongwei; Kong, Hongru; Chen, Zongjing; Chen, Bicheng; Zhou, Mengtao

    2017-01-01

    Pancreatic carcinoma (PC) is the one of the most common and malignant cancers worldwide. LncRNA taurine upregulated gene 1 (TUG1) was initially identified as a transcript upregulated by taurine, and the abnormal expression of TUG1 has been reported in many cancers. However, the biological role and molecular mechanism of TUG1 in PC still needs further investigation. Quantitative real-time PCR (qRT-PCR) was performed to measure the expression of TUG1 in PC cell lines and tissues. MTT and colony formation assays were used to measure the effect of TUG1 on cell proliferation. A wound healing assay, transwell assay and western blot assay were employed to determine the effect of TUG1 on cell migration and the epithelial mesenchymal transition (EMT) phenotype. RNA-binding protein immunoprecipitation (RIP) and a biotin-avidin pulldown system were performed to confirm the interaction between miR-328 and TUG1. A gene expression array analysis using clinical samples and RT-qPCR suggested that enhancer of zeste homolog 2 (EZH2) was a target of miR-382 in PC. In this study, we reported that TUG1 was overexpressed in PC tissues and cell lines, and high expression of TUG1 predicted poor prognosis. Further experiments revealed that overexpressed TUG1 promoted cell proliferation, migration and contributed to EMT formation, whereas silenced TUG1 led to opposing results. Additionally, luciferase reporter assays, an RIP assay and an RNA-pulldown assay demonstrated that TUG1 could competitively sponge miR-382 and thereby regulate EZH2. Collectively, these findings revealed that TUG1 functions as an oncogenic lncRNA that promotes tumor progression, at least partially, by functioning as an endogenous 'sponge' and competing for miR-382 binding to the miRNA target EZH2. © 2017 The Author(s). Published by S. Karger AG, Basel.

  7. The Lncrna-TUG1/EZH2 Axis Promotes Pancreatic Cancer Cell Proliferation, Migration and EMT Phenotype Formation Through Sponging Mir-382

    Directory of Open Access Journals (Sweden)

    Liang Zhao

    2017-08-01

    Full Text Available Background/Aims: Pancreatic carcinoma (PC is the one of the most common and malignant cancers worldwide. LncRNA taurine upregulated gene 1 (TUG1 was initially identified as a transcript upregulated by taurine, and the abnormal expression of TUG1 has been reported in many cancers. However, the biological role and molecular mechanism of TUG1 in PC still needs further investigation. Methods: Quantitative real-time PCR (qRT-PCR was performed to measure the expression of TUG1 in PC cell lines and tissues. MTT and colony formation assays were used to measure the effect of TUG1 on cell proliferation. A wound healing assay, transwell assay and western blot assay were employed to determine the effect of TUG1 on cell migration and the epithelial mesenchymal transition (EMT phenotype. RNA-binding protein immunoprecipitation (RIP and a biotin-avidin pulldown system were performed to confirm the interaction between miR-328 and TUG1. A gene expression array analysis using clinical samples and RT-qPCR suggested that enhancer of zeste homolog 2 (EZH2 was a target of miR-382 in PC. Results: In this study, we reported that TUG1 was overexpressed in PC tissues and cell lines, and high expression of TUG1 predicted poor prognosis. Further experiments revealed that overexpressed TUG1 promoted cell proliferation, migration and contributed to EMT formation, whereas silenced TUG1 led to opposing results. Additionally, luciferase reporter assays, an RIP assay and an RNA-pulldown assay demonstrated that TUG1 could competitively sponge miR-382 and thereby regulate EZH2. Conclusion: Collectively, these findings revealed that TUG1 functions as an oncogenic lncRNA that promotes tumor progression, at least partially, by functioning as an endogenous ‘sponge’ and competing for miR-382 binding to the miRNA target EZH2.

  8. Absolute nuclear material assay

    Science.gov (United States)

    Prasad, Manoj K [Pleasanton, CA; Snyderman, Neal J [Berkeley, CA; Rowland, Mark S [Alamo, CA

    2010-07-13

    A method of absolute nuclear material assay of an unknown source comprising counting neutrons from the unknown source and providing an absolute nuclear material assay utilizing a model to optimally compare to the measured count distributions. In one embodiment, the step of providing an absolute nuclear material assay comprises utilizing a random sampling of analytically computed fission chain distributions to generate a continuous time-evolving sequence of event-counts by spreading the fission chain distribution in time.

  9. Periodontal Ligament Mesenchymal Stromal Cells Increase Proliferation and Glycosaminoglycans Formation of Temporomandibular Joint Derived Fibrochondrocytes

    Directory of Open Access Journals (Sweden)

    Jianli Zhang

    2014-01-01

    Full Text Available Objectives. Temporomandibular joint (TMJ disorders are common disease in maxillofacial surgery. The aim of this study is to regenerate fibrocartilage with a mixture of TMJ fibrochondrocytes and periodontal ligament derived mesenchymal stem cells (PD-MSCs. Materials and Methods. Fibrochondrocytes and PD-MSC were cocultured (ratio 1 : 1 for 3 weeks. Histology and glycosaminoglycans (GAGs assay were performed to examine the deposition of GAG. Green florescent protein (GFP was used to track PD-MSC. Conditioned medium of PD-MSCs was collected to study the soluble factors. Gene expression of fibrochondrocytes cultured in conditioned medium was tested by quantitative PCR (qPCR. Results. Increased proliferation of TMJ-CH was observed in coculture pellets when compared to monoculture. Enhanced GAG production in cocultures was shown by histology and GAG quantification. Tracing of GFP revealed the fact that PD-MSC disappears after coculture with TMJ-CH for 3 weeks. In addition, conditioned medium of PD-MSC was also shown to increase the proliferation and GAG deposition of TMJ-CH. Meanwhile, results of qPCR demonstrated that conditioned medium enhanced the expression levels of matrix-related genes in TMJ-CH. Conclusions. Results from this study support the mechanism of MSC-chondrocyte interaction, in which MSCs act as secretor of soluble factors that stimulate proliferation and extracellular matrix deposition of chondrocytes.

  10. Biocompatibility evaluation in vitro. Part I: Morphology expression and proliferation of human and rat osteoblasts on the biomaterials

    Institute of Scientific and Technical Information of China (English)

    2001-01-01

    The biocompatibility evaluation of calcium phosphate based biomaterials is performed by tissue culture in vitro model. Three kinds of bioceramic materials which are potential to deal with bone trauma and/or conduct tissue growth are recommodated. The biological research results show that human and animal osteoblast cells anchor the materials surface in two hours in culture. Confocal laser scanning microscopy (CLSM) demonstrated the normal cell distribution and proliferation on both of dense and porous biomaterials. Hydroxyapatite and tricalcium phosphate stimulate cell proliferation. However, DNA and protein synthesis were considerably limited and the apoptosis phenomenon would be present on the hydroxyapatite (HA) materials by adding Al, Mg elements. Several important methods of biocompatibility evaluation of implant materials are described and the related biological molecular techniques such as tissue culture, cell transfection, cellular DNA stain, and Lowry assay are involved in the present research.

  11. Tissue expander stimulated lengthening of arteries (TESLA) induces early endothelial cell proliferation in a novel rodent model.

    Science.gov (United States)

    Potanos, Kristina; Fullington, Nora; Cauley, Ryan; Purcell, Patricia; Zurakowski, David; Fishman, Steven; Vakili, Khashayar; Kim, Heung Bae

    2016-04-01

    We examine the mechanism of aortic lengthening in a novel rodent model of tissue expander stimulated lengthening of arteries (TESLA). A rat model of TESLA was examined with a single stretch stimulus applied at the time of tissue expander insertion with evaluation of the aorta at 2, 4 and 7day time points. Measurements as well as histology and proliferation assays were performed and compared to sham controls. The aortic length was increased at all time points without histologic signs of tissue injury. Nuclear density remained unchanged despite the increase in length suggesting cellular hyperplasia. Cellular proliferation was confirmed in endothelial cell layer by Ki-67 stain. Aortic lengthening may be achieved using TESLA. The increase in aortic length can be achieved without tissue injury and results at least partially from cellular hyperplasia. Further studies are required to define the mechanisms involved in the growth of arteries under increased longitudinal stress. Copyright © 2015 Elsevier Inc. All rights reserved.

  12. Harmonization of radiobiological assays: why and how?

    International Nuclear Information System (INIS)

    Prasanna, Pataje G.

    2014-01-01

    The International Atomic Energy Agency has made available a technical manual for cytogenetic biodosimetry assays (dicentric chromosome aberration (DCA) and cytokinesis-block micronucleus (CBMN) assays) used for radiation dose assessment in radiation accidents. The International Standardization Organization, which develops standards and guidelines, also provides an avenue for laboratory accreditation, has developed guidelines and recommendations for performing cytogenetic biodosimetry assays. Harmonization of DCA and CBMN assays, has improved their accuracy. Double-blinded inter-laboratory comparison studies involving several networks have further validated DCA and CBMN assays and improved the confidence in their potential use for radiation dose assessment in mass casualties. This kind of international harmonization is lacking for pre-clinical radiobiology assays. The widely used pre-clinical assays that are relatively important to set stage for clinical trials include clonogenic assays, flow-cytometry assays, apoptotic assays, and tumor regression and growth delay assays. However, significant inter-laboratory variations occur with respect to data among laboratories. This raises concerns on the reliability and reproducibility of preclinical data that drives further development and translation. Lack of reproducibility may stem from a variety of factors such as poor scientist training, less than optimal experimental design, inadequate description of methodology, and impulse to publish only the positive data etc. Availability of technical manuals, standard operating procedures, accreditation avenues for laboratories performing such assays, inter-laboratory comparisons, and use of standardized protocols are necessary to enhance reliability and reproducibility. Thus, it is important that radiobiological assays are harmonized for laboratory protocols to ensure successful translation of pre-clinical research on radiation effect modulators to help design clinic trials with

  13. Platelet-rich plasma (PRP) and adipose-derived mesenchymal stem cells: stimulatory effects on proliferation and migration of fibroblasts and keratinocytes in vitro.

    Science.gov (United States)

    Stessuk, Talita; Puzzi, Maria Beatriz; Chaim, Elinton Adami; Alves, Paulo César Martins; de Paula, Erich Vinicius; Forte, Andresa; Izumizawa, Juliana Massae; Oliveira, Carolina Caliári; Frei, Fernando; Ribeiro-Paes, João Tadeu

    2016-09-01

    The clinical use of tissue engineering associated with cell therapy is considered a new alternative therapy for the repair of chronic lesions with potential application in different medical areas, mostly in orthopedic and dermatological diseases. Platelet-rich plasma (PRP) is a rich source of growth factors and cytokines important for wound healing. Adipose-derived mesenchymal stem cells (ADSCs) have shown potential to accelerate the resolution of ulcers, to stimulate cell proliferation, and to benefit the quality of skin repair. This study aims to determine the effect of PRP and conditioned medium (CM) from ADSC on fibroblast and keratinocyte proliferation in vitro. Migration and proliferation assays were performed to evaluate the growth of fibroblasts and keratinocytes in the presence of PRP, CM, and CM + PRP. Significant proliferative stimulation was observed after 48 h of culture (p PRP, 100 % CM, and 25 % PRP + 25 % CM, if compared with control. Keratinocyte proliferation was stimulated after 48 h in cultures with 25, 50, and 100 % CM, and growth was compared with controls. The migration assay detected a significant migratory stimulus in fibroblasts cultured with 10 % PRP + 10 % CM after 48 h. These in vitro results suggest that PRP and ADSC have therapeutic potential for healing and re-epithelialization of chronic wounds in vivo.

  14. [Roles of Y box-binding protein 1 in SK-BR-3 breast cancer proliferation].

    Science.gov (United States)

    Shi, Jianhong; Lü, Xinrui; Wang, Bing; Daudan, Lin; Yanan, Wang; Yuhui, Bu; Zhenfeng, Ma

    2014-09-30

    To explore the roles of Y box-binding protein 1 (YB-1) in breast cancer cell proliferation. Twenty cases of surgical removal of breast cancer tissue (diagnosed with invasive ductal carcinoma, stage II, by postoperative paraffin pathology) and normal breast tissues adjacent to carcinoma were collected during June 2013 to August 2013.Quantitative real-time PCR (qRT-PCR) was performed to detect the YB1 mRNA levels. Cultured mammary epithelial cells (HBL-100) and breast cancer cells (MCF7, MDA-MB-231 & SK-BR-3 cells) were harvested and qRT-PCR was performed to detect the YB1 mRNA levels.SK-BR-3 cells were stimulated with various concentrations of PDGF-BB and YB1 expression levels were detected by qRT-PCR. Down-regulation or over-expression of YB1 by si-YB1 or Ad-GFP-YB1 was detected in SK-BR-3 cells. And MTS cell proliferation assay kit was used to detect cell proliferation. YB1 mRNA levels were significantly higher in breast cancer tissues and MDA-MB-231 and SK-BR-3 breast cancer cell lines than that in adjacent normal breast tissues and HBL-100 mammary epithelial cells respectively (P BR-3 cells in a dose-dependent manner. A down-regulation of endogenous YB1 decreases and an over-expression of exogenous YB1 promotes the proliferation activity in SK-BR-3 cells.

  15. Comparison of Batch Assay and Random Assay Using Automatic Dispenser in Radioimmunoassay

    Energy Technology Data Exchange (ETDEWEB)

    Moon, Seung Hwan; Jang, Su Jin; Kang, Ji Yeon; Lee, Dong Soo; Chung, June Key; Lee, Myung Chul [Seoul Metropolitan Government Seoul National University Boramae Medical Center, Seoul (Korea, Republic of); Lee, Ho Young; Shin, Sun Young; Min, Gyeong Sun; Lee, Hyun Joo [Seoul National University college of Medicine, Seoul (Korea, Republic of)

    2009-08-15

    Radioimmunoassay (RIA) was usually performed by the batch assay. To improve the efficiency of RIA without increase of the cost and time, random assay could be a choice. We investigated the possibility of the random assay using automatic dispenser by assessing the agreement between batch assay and random assay. The experiments were performed with four items; Triiodothyronine (T3), free thyroxine (fT4), Prostate specific antigen (PSA), Carcinoembryonic antigen (CEA). In each item, the sera of twenty patients, the standard, and the control samples were used. The measurements were done 4 times with 3 hour time intervals by random assay and batch assay. The coefficient of variation (CV) of the standard samples and patients' data in T3, fT4, PSA, and CEA were assessed. ICC (Intraclass correlation coefficient) and coefficient of correlation were measured to assessing the agreement between two methods. The CVs (%) of T3, fT4, PSA, and CEA measured by batch assay were 3.2+-1.7%, 3.9+-2.1%, 7.1+-6.2%, 11.2+-7.2%. The CVs by random assay were 2.1+-1.7%, 4.8+-3.1%, 3.6+-4.8%, and 7.4+-6.2%. The ICC between the batch assay and random assay were 0.9968 (T3), 0.9973 (fT4), 0.9996 (PSA), and 0.9901 (CEA). The coefficient of correlation between the batch assay and random assay were 0.9924(T3), 0.9974 (fT4), 0.9994 (PSA), and 0.9989 (CEA) (p<0.05). The results of random assay showed strong agreement with the batch assay in a day. These results suggest that random assay using automatic dispenser could be used in radioimmunoassay

  16. Comparison of Batch Assay and Random Assay Using Automatic Dispenser in Radioimmunoassay

    International Nuclear Information System (INIS)

    Moon, Seung Hwan; Jang, Su Jin; Kang, Ji Yeon; Lee, Dong Soo; Chung, June Key; Lee, Myung Chul; Lee, Ho Young; Shin, Sun Young; Min, Gyeong Sun; Lee, Hyun Joo

    2009-01-01

    Radioimmunoassay (RIA) was usually performed by the batch assay. To improve the efficiency of RIA without increase of the cost and time, random assay could be a choice. We investigated the possibility of the random assay using automatic dispenser by assessing the agreement between batch assay and random assay. The experiments were performed with four items; Triiodothyronine (T3), free thyroxine (fT4), Prostate specific antigen (PSA), Carcinoembryonic antigen (CEA). In each item, the sera of twenty patients, the standard, and the control samples were used. The measurements were done 4 times with 3 hour time intervals by random assay and batch assay. The coefficient of variation (CV) of the standard samples and patients' data in T3, fT4, PSA, and CEA were assessed. ICC (Intraclass correlation coefficient) and coefficient of correlation were measured to assessing the agreement between two methods. The CVs (%) of T3, fT4, PSA, and CEA measured by batch assay were 3.2±1.7%, 3.9±2.1%, 7.1±6.2%, 11.2±7.2%. The CVs by random assay were 2.1±1.7%, 4.8±3.1%, 3.6±4.8%, and 7.4±6.2%. The ICC between the batch assay and random assay were 0.9968 (T3), 0.9973 (fT4), 0.9996 (PSA), and 0.9901 (CEA). The coefficient of correlation between the batch assay and random assay were 0.9924(T3), 0.9974 (fT4), 0.9994 (PSA), and 0.9989 (CEA) (p<0.05). The results of random assay showed strong agreement with the batch assay in a day. These results suggest that random assay using automatic dispenser could be used in radioimmunoassay

  17. High-performance thin-layer chromatography linked with (bio)assays and mass spectrometry - a suited method for discovery and quantification of bioactive components? Exemplarily shown for turmeric and milk thistle extracts.

    Science.gov (United States)

    Taha, Mahmoud N; Krawinkel, Michael B; Morlock, Gertrud E

    2015-05-15

    Extraction parameters, chemical fingerprint, and the single compounds' activity levels were considered for the selection of active botanicals. For an initial survey, the total bioactivity (i.e., total reducing capacity, total flavonoids contents and free radical scavenging capacity) of 21 aqueous and 21 ethanolic plant extracts was investigated. Ethanolic extracts showed a higher yield and were further analyzed by HPTLC in detail to obtain fingerprints of single flavonoids and further bioactive components. Exemplarily shown for turmeric (Curcuma longa) and milk thistle (Silybum marianum), effect-directed analysis (EDA) was performed using three selected (bio)assays, the Aliivibrio fischeri bioassay, the Bacillus subtilis bioassay and the 2,2-diphenyl-1-picrylhydrazyl (DPPH*) assay. As a proof of principle, the bioactive components found in the extracts were confirmed by HPTLC-MS. Bioassays in combination with planar chromatography directly linked to the known, single effective compounds like curcumin and silibinin. However, also some unknown bioactive components were discovered and exemplarily characterized, which demonstrated the strength of this kind of EDA. HPTLC-UV/Vis/FLD-EDA-MS could become a useful tool for selection of active botanicals and for the activity profiling of the active ingredients therein. The flexibility in effect-directed detections allows a comprehensive survey of effective ingredients in samples. This streamlined methodology comprised a non-targeted, effect-directed screening first, followed by a highly targeted characterization of the discovered bioactive compounds. HPTLC-EDA-MS can also be recommended for bioactivity profiling of food on the food intake side, as not only effective phytochemicals, but also unknown bioactive degradation products during food processing or contamination products or residues or metabolites can be detected. Thus, an efficient survey on potential food intake effects on wellness could be obtained. Having performed

  18. Basic Fibroblast Growth Factor Stimulates the Proliferation of Bone Marrow Mesenchymal Stem Cells in Giant Panda (Ailuropoda melanoleuca).

    Science.gov (United States)

    Wang, Jun-Jie; Liu, Yu-Liang; Sun, Yuan-Chao; Ge, Wei; Wang, Yong-Yong; Dyce, Paul W; Hou, Rong; Shen, Wei

    2015-01-01

    It has been widely known that the giant panda (Ailuropoda melanoleuca) is one of the most endangered species in the world. An optimized platform for maintaining the proliferation of giant panda mesenchymal stem cells (MSCs) is very necessary for current giant panda protection strategies. Basic fibroblast growth factor (bFGF), a member of the FGF family, is widely considered as a growth factor and differentiation inducer within the stem cell research field. However, the role of bFGF on promoting the proliferation of MSCs derived from giant panda bone marrow (BM) has not been reported. In this study, we aimed to investigate the role of bFGF on the proliferation of BM-MSCs derived from giant panda. MSCs were cultured for cell proliferation analysis at 24, 48 and 72 hrs following the addition of bFGF. With increasing concentrations of bFGF, cell numbers gradually increased. This was further demonstrated by performing 3-(4,5-dimethyl-2-thiazolyl)-2,5-diphenyl-2-H-tetrazolium bromide (MTT) cell proliferation assay, 5-Bromo-2-deoxyUridine (BrdU) labeling and cell cycle testing. Furthermore, the percentage of MSCs that were OCT4 positive increased slightly following treatment with 5 ng/ml bFGF. Moreover, we demonstrated that the extracellular signal-regulated kinase (ERK) signaling pathway may play an important role in the proliferation of panda MSCs stimulated by bFGF. In conclusion, this study suggests that giant panda BM-MSCs have a high proliferative capacity with the addition of 5 ng/ml bFGF in vitro.

  19. Basic Fibroblast Growth Factor Stimulates the Proliferation of Bone Marrow Mesenchymal Stem Cells in Giant Panda (Ailuropoda melanoleuca)

    Science.gov (United States)

    Wang, Jun-Jie; Liu, Yu-Liang; Sun, Yuan-Chao; Ge, Wei; Wang, Yong-Yong; Dyce, Paul W.; Hou, Rong; Shen, Wei

    2015-01-01

    It has been widely known that the giant panda (Ailuropoda melanoleuca) is one of the most endangered species in the world. An optimized platform for maintaining the proliferation of giant panda mesenchymal stem cells (MSCs) is very necessary for current giant panda protection strategies. Basic fibroblast growth factor (bFGF), a member of the FGF family, is widely considered as a growth factor and differentiation inducer within the stem cell research field. However, the role of bFGF on promoting the proliferation of MSCs derived from giant panda bone marrow (BM) has not been reported. In this study, we aimed to investigate the role of bFGF on the proliferation of BM-MSCs derived from giant panda. MSCs were cultured for cell proliferation analysis at 24, 48 and 72 hrs following the addition of bFGF. With increasing concentrations of bFGF, cell numbers gradually increased. This was further demonstrated by performing 3-(4,5-dimethyl-2-thiazolyl)-2,5-diphenyl-2-H-tetrazolium bromide (MTT) cell proliferation assay, 5-Bromo-2-deoxyUridine (BrdU) labeling and cell cycle testing. Furthermore, the percentage of MSCs that were OCT4 positive increased slightly following treatment with 5 ng/ml bFGF. Moreover, we demonstrated that the extracellular signal-regulated kinase (ERK) signaling pathway may play an important role in the proliferation of panda MSCs stimulated by bFGF. In conclusion, this study suggests that giant panda BM-MSCs have a high proliferative capacity with the addition of 5 ng/ml bFGF in vitro. PMID:26375397

  20. Basic Fibroblast Growth Factor Stimulates the Proliferation of Bone Marrow Mesenchymal Stem Cells in Giant Panda (Ailuropoda melanoleuca.

    Directory of Open Access Journals (Sweden)

    Jun-Jie Wang

    Full Text Available It has been widely known that the giant panda (Ailuropoda melanoleuca is one of the most endangered species in the world. An optimized platform for maintaining the proliferation of giant panda mesenchymal stem cells (MSCs is very necessary for current giant panda protection strategies. Basic fibroblast growth factor (bFGF, a member of the FGF family, is widely considered as a growth factor and differentiation inducer within the stem cell research field. However, the role of bFGF on promoting the proliferation of MSCs derived from giant panda bone marrow (BM has not been reported. In this study, we aimed to investigate the role of bFGF on the proliferation of BM-MSCs derived from giant panda. MSCs were cultured for cell proliferation analysis at 24, 48 and 72 hrs following the addition of bFGF. With increasing concentrations of bFGF, cell numbers gradually increased. This was further demonstrated by performing 3-(4,5-dimethyl-2-thiazolyl-2,5-diphenyl-2-H-tetrazolium bromide (MTT cell proliferation assay, 5-Bromo-2-deoxyUridine (BrdU labeling and cell cycle testing. Furthermore, the percentage of MSCs that were OCT4 positive increased slightly following treatment with 5 ng/ml bFGF. Moreover, we demonstrated that the extracellular signal-regulated kinase (ERK signaling pathway may play an important role in the proliferation of panda MSCs stimulated by bFGF. In conclusion, this study suggests that giant panda BM-MSCs have a high proliferative capacity with the addition of 5 ng/ml bFGF in vitro.

  1. The threonine protease activity of testes-specific protease 50 (TSP50 is essential for its function in cell proliferation.

    Directory of Open Access Journals (Sweden)

    Yu-Yin Li

    Full Text Available BACKGROUND: Testes-specific protease 50 (TSP50, a newly discovered threonine enzyme, has similar amino acid sequences and enzymatic structures to those of many serine proteases. It may be an oncogene. TSP50 is up-regulated in breast cancer epithelial cells, and ectopic expression of TSP50 in TSP50-deficient Chinese hamster ovary (CHO cells has been found to promote cell proliferation. However, the mechanisms by which TSP50 exerts its growth-promoting effects are not yet fully understood. METHODOLOGY/PRINCIPAL FINDINGS: To delineate whether the threonine protease activity of TSP50 is essential to its function in cell proliferation, we constructed and characterized a mutant TSP50, called TSP50 T310A, which was identified as a protease-dead mutant of TSP50. By a series of proliferation analyses, colony formation assays and apoptosis analyses, we showed that T310A mutation significantly depresses TSP50-induced cell proliferation in vitro. Next, the CHO stable cell line expressing either wild-type or T310A mutant TSP50 was injected subcutaneously into nude mice. We found that the T310A mutation could abolish the tumorigenicity of TSP50 in vivo. A mechanism investigation revealed that the T310A mutation prevented interaction between TSP50 and the NF-κBIκBα complex, which is necessary for TSP50 to perform its function in cell proliferation. CONCLUSION: Our data highlight the importance of threonine 310, the most critical protease catalytic site in TSP50, to TSP50-induced cell proliferation and tumor formation.

  2. Downregulation of the long non-coding RNA taurine-upregulated gene 1 inhibits glioma cell proliferation and invasion and promotes apoptosis.

    Science.gov (United States)

    Zhao, Zhijun; Wang, Bin; Hao, Junhai; Man, Weitao; Chang, Yongkai; Ma, Shunchang; Hu, Yeshuai; Liu, Fusheng; Yang, Jun

    2018-03-01

    Expression of the long non-coding RNA taurine-upregulated gene 1 (TUG1) is associated with various aggressive tumors. The present study aimed to investigate the biological function of TUG1 in regulating apoptosis, proliferation, invasion and cell cycle distribution in human glioma U251 cells. Lentivirus-mediated TUG1-specific microRNA was transfected into U251 cells to abrogate the expression of TUG1. Flow cytometry analysis was used to examine the cell cycle distribution and apoptosis of U251 cells. Cellular proliferation was examined using Cell Counting Kit-8 (CCK-8) assays and invasion was examined by Transwell assays. The apoptotic rate of cells in the TUG1-knockdown group was significantly higher than in the negative control (NC) group (11.58 vs. 9.14%, PTUG1-knockdown group was lower compared with that of the NC group. A Transwell invasion assay was performed, which revealed that the number of invaded cells from the TUG1-knockdown group was the less compared with that of the NC group. In addition, the G 0 /G 1 phase population was significantly increased within the treated group (44.85 vs. 38.45%, PTUG1 may inhibit proliferation and invasion, and promote glioma U251 cell apoptosis. In addition, knockdown of TUG1 may have an effect on cell cycle arrest. The data presented in the current study indicated that TUG1 may be a novel therapeutic target for glioma.

  3. MiR-129-5p Inhibits Proliferation and Invasion of Chondrosarcoma Cells by Regulating SOX4/Wnt/β-Catenin Signaling Pathway.

    Science.gov (United States)

    Zhang, Peng; Li, Jifeng; Song, Yuze; Wang, Xiao

    2017-01-01

    Recently, microRNAs (miRNA) have been identified as novel regulators in Chondrosarcoma (CHS). This study was aimed to identify the roles of miR-129-5p-5p in regulation of SOX4 and Wnt/β-catenin signaling pathway, as well as cell proliferation and apoptosis in chondrosarcomas. Tissue samples were obtained from chondrosarcoma patients. Immunohistochemistry, real-time quantitative RT-PCR (RT-qPCR) and western blot analysis were performed to detect the expressions of miR-129-5p and SOX4. Luciferase assay was conducted to confirm that miR-129-5p directly targeted SOX4 mRNA. Manipulations of miR-129-5p and SOX4 expression were achieved through cell transfection. Cell proliferation, migration and apoptosis were evaluated by CCK-8 assay, colony forming assay, wound healing assay and flow cytometry in vitro. For in vivo experiment, the tumor xenograft model was established to evaluate the effects of miR-129-5p and SOX4 on chondrosarcomas. The expression of miR-129-5p was significantly down-regulated in chondrosarcoma tissues as well as cells in comparison with normal ones, while SOX4 was over-activated. Further studies suggested that miR-129-5p suppressed cell proliferation, migration and promoted apoptosis by inhibiting SOX4 and Wnt/β-catenin pathway. MiR-129-5p inhibits the Wnt/β-catenin signaling pathway by targeting SOX4 and further suppresses cell proliferation, migration and promotes apoptosis in chondrosarcomas. © 2017 The Author(s). Published by S. Karger AG, Basel.

  4. Effect of platelet-rich plasma (PRP) concentration on proliferation, neurotrophic function and migration of Schwann cells in vitro.

    Science.gov (United States)

    Zheng, Canbin; Zhu, Qingtang; Liu, Xiaolin; Huang, Xijun; He, Caifeng; Jiang, Li; Quan, Daping; Zhou, Xiang; Zhu, Zhaowei

    2016-05-01

    Platelet-rich plasma (PRP) contains various growth factors and appears to have the potential to promote peripheral nerve regeneration, but evidence is lacking regarding its biological effect on Schwann cells (SCs). The present study was designed to investigate the effect of PRP concentration on SCs in order to determine the plausibility of using this plasma-derived therapy for peripheral nerve injury. PRP was obtained from rats by double-step centrifugation and was characterized by determining platelet numbers and growth factor concentrations. Primary cultures of rat SCs were exposed to various concentrations of PRP (40%, 20%, 10%, 5% and 2.5%). Cell proliferation assays and flow cytometry were performed to study to assess SC proliferation. Quantitative real-time PCR and ELISA analysis were performed to determine the ability of PRP to induce SCs to produce nerve growth factor (NGF) and glial cell line-derived neurotrophic factor (GDNF). Microchemotaxis assay was used to analyse the cell migration capacity. The results obtained indicated that the platelet concentration and growth factors in our PRP preparations were significantly higher than in whole blood. Cell culture experiments showed that 2.5-20% PRP significantly stimulated SC proliferation and migration compared to untreated controls in a dose-dependent manner. In addition, the expression and secretion of NGF and GDNF were significantly increased. However, the above effects of SCs were suppressed by high PRP concentrations (40%). In conclusion, the appropriate concentration of PRP had the potency to stimulate cell proliferation, induced the synthesis of neurotrophic factors and significantly increased migration of SCs dose-dependently. Copyright © 2013 John Wiley & Sons, Ltd. Copyright © 2013 John Wiley & Sons, Ltd.

  5. Diagnostic performance of an indirect enzyme-linked immunosorbent assay (ELISA) to detect bovine leukemia virus antibodies in bulk-tank milk samples

    Science.gov (United States)

    Nekouei, Omid; Durocher, Jean; Keefe, Greg

    2016-01-01

    This study assessed the diagnostic performance of a commercial ELISA for detecting bovine leukemia virus antibodies in bulk-tank milk samples from eastern Canada. Sensitivity and specificity of the test were estimated at 97.2% and 100%, respectively. The test was recommended as a cost-efficient tool for large-scale screening programs. PMID:27429469

  6. Nuclear proliferation: linkages and solutions

    International Nuclear Information System (INIS)

    Quester, G.H.

    1979-01-01

    Nuclear proliferation must be periodically re-examined as a moral as well as a practical foreign policy dilemma. The question is asked whether proliferation precludes a safe and peaceful world, or if a halt to proliferation is adequate without other arms control. The moral dilemma in foreign policy arises over the need to make practical choices which often serve one goal while sacrificing another. The ramifications of nuclear proliferation are examined and the conclusions reached that it is not an acceptable option. It is also decided that, because general disarmament steps will be more difficult to achieve, the world may have to accept a small number of nuclear arsenals as the price of state sovereignties. A high priority for making the effort to prevent proliferation is advised. 8 references

  7. Expert system for transuranic waste assay

    Energy Technology Data Exchange (ETDEWEB)

    Zoolalian, M.L.; Gibbs, A.; Kuhns, J.D.

    1989-01-01

    Transuranic wastes are generated at the Savannah River Site (SRS) as a result of routine production of nuclear materials. These wastes contain Pu-238 and Pu-239 and are placed into lined 55-gallon waste drums. The drums are placed on monitored storage pads pending shipment to the Waste Isolation Pilot Plant in New Mexico. A passive-active neutron (PAN) assay system is used to determine the mass of the radioactive material within the waste drums. Assay results are used to classify the wastes as either low-level or transuranic (TRU). During assays, the PAN assay system communicates with an IBM-AT computer. A Fortran computer program, called NEUT, controls and performs all data analyses. Unassisted, the NEUT program cannot adequately interpret assay results. To eliminate this limitation, an expert system shell was used to write a new algorithm, called the Transuranic Expert System (TRUX), to drive the NEUT program and add decision making capabilities for analysis of the assay results. The TRUX knowledge base was formulated by consulting with human experts in the field of neutron assay, by direct experimentation on the PAN assay system, and by observing operations on a daily basis. TRUX, with its improved ability to interpret assay results, has eliminated the need for close supervision by a human expert, allowing skilled technicians to operate the PAN assay system. 4 refs., 1 fig., 4 tabs.

  8. Expert system for transuranic waste assay

    International Nuclear Information System (INIS)

    Zoolalian, M.L.; Gibbs, A.; Kuhns, J.D.

    1989-01-01

    Transuranic wastes are generated at the Savannah River Site (SRS) as a result of routine production of nuclear materials. These wastes contain Pu-238 and Pu-239 and are placed into lined 55-gallon waste drums. The drums are placed on monitored storage pads pending shipment to the Waste Isolation Pilot Plant in New Mexico. A passive-active neutron (PAN) assay system is used to determine the mass of the radioactive material within the waste drums. Assay results are used to classify the wastes as either low-level or transuranic (TRU). During assays, the PAN assay system communicates with an IBM-AT computer. A Fortran computer program, called NEUT, controls and performs all data analyses. Unassisted, the NEUT program cannot adequately interpret assay results. To eliminate this limitation, an expert system shell was used to write a new algorithm, called the Transuranic Expert System (TRUX), to drive the NEUT program and add decision making capabilities for analysis of the assay results. The TRUX knowledge base was formulated by consulting with human experts in the field of neutron assay, by direct experimentation on the PAN assay system, and by observing operations on a daily basis. TRUX, with its improved ability to interpret assay results, has eliminated the need for close supervision by a human expert, allowing skilled technicians to operate the PAN assay system. 4 refs., 1 fig., 4 tabs

  9. ER-α36 mediates estrogen-stimulated MAPK/ERK activation and regulates migration, invasion, proliferation in cervical cancer cells

    International Nuclear Information System (INIS)

    Sun, Qing; Liang, Ying; Zhang, Tianli; Wang, Kun; Yang, Xingsheng

    2017-01-01

    Objective: Estrogen receptor alpha 36 (ER-α36), a truncated variant of ER-α, is different from other nuclear receptors of the ER-α family. Previous findings indicate that ER-α36 might be involved in cell growth, proliferation, and differentiation in carcinomas and primarily mediates non-genomic estrogen signaling. However, studies on ER-α36 and cervical cancer are rare. This study aimed to detect the expression of ER-α36 in cervical cancer; the role of ER-α36 in 17-β-estradiol (E2)-induced invasion, migration and proliferation of cervical cancer; and their probable molecular mechanisms. Methods: Immunohistochemistry and immunofluorescence were used to determine the location of ER-α36 in cervical cancer tissues and cervical cell lines. CaSki and HeLa cell lines were transfected with lentiviruses to establish stable cell lines with knockdown and overexpression of ER-α36. Wound healing assay, transwell invasion assay, and EdU incorporation proliferation assay were performed to evaluate the migration, invasion, and proliferation ability. The phosphorylation levels of mitogen-activated protein kinases/extracellular signal-regulated kinase (MAPK/ERK) signaling molecules were examined with western blot analysis. Results: ER-α36 expression was detected in both cervical cell lines and cervical cancer tissues. Downregulation of ER-α36 significantly inhibited cell invasion, migration, and proliferation. Moreover, upregulation of ER-α36 increased the invasion, migration, and proliferation ability of CaSki and HeLa cell lines. ER-α36 mediates estrogen-stimulated MAPK/ERK activation. Conclusion: ER-α36 is localized on the plasma membrane and cytoplasm in both cervical cancer tissues and cell lines. ER-α36 mediates estrogen-stimulated MAPK/ERK activation and regulates migration, invasion, proliferation in cervical cancer cells. - Highlights: • ER-α36 is expressed on both cervical cell lines and cervical cancer tissues. • ER-α36 mediates estrogen

  10. MicroRNA-199a-5p Regulates the Proliferation of Pulmonary Microvascular Endothelial Cells in Hepatopulmonary Syndrome

    Directory of Open Access Journals (Sweden)

    Jing Zeng

    2015-10-01

    Full Text Available Background/Aims: Pulmonary microvascular endothelial cell (PMVEC proliferation and angiogenesis contribute to the development of hepatopulmonary syndrome (HPS. MicroRNA-199a-5p (miR-199a-5p has emerged as a potent regulator of angiogenesis, and its expression levels significantly decrease in the serum of patients with hepatopathy. However, it has not been reported about whether miR-199a-5p might control PMVEC proliferation. Here, we described the miR-199a-5p governing PMVEC proliferation in HPS. Methods: PMVECs were treated with rat serum from common bile duct ligation (CBDL or sham. MiR-199a-5p mimic or inhibitor was used to change the miR-199a-5p expression. Knockdown of caveolin-1 (Cav-1 was performed using siRNA. NSC-23766 was used to inhibit Rac1 activity. Gene and protein expressions were quantified by qRT-PCR and western blot. Cell proliferation was analyzed by 3H-TdR incorporation and CCK-8 assays. Stress fibers were detected by immunofluorescence. Results: CBDL rat serum induced the down-regulation of miR-199a-5p. Delivery of miR-199a-5p suppressed the CBDL rat serum-induced PMVEC proliferation whereas knockdown of miR-199a-5p promoted PMVEC proliferation. This was accompanied by a decrease and an increase in Cav-1 expression, respectively. Cav-1 siRNA abolished the enhancement of PMVEC proliferation induced by the miR-199a-5p inhibition. Although stress fibers were disrupted in Cav-1 deficient cells, NSC-23766 increased stress fibers and contributed to cell proliferation. Conclusions: CBDL rat serum induced down-regulation of miR-199a-5p in PMVECs, which led to an increase of Cav-1 gene expression. Increased Cav-1 expression, by inhibiting Rac1 activity, led to the formation of stress fibers, which contribute to PMVEC proliferation and thus the pathogenesis of HPS.

  11. Analytical performance specifications for changes in assay bias (Δbias) for data with logarithmic distributions as assessed by effects on reference change values

    DEFF Research Database (Denmark)

    Hyltoft Petersen, Per; Lund, Flemming; Fraser, Callum G

    2016-01-01

    BACKGROUND: The distributions of within-subject biological variation are usually described as coefficients of variation, as are analytical performance specifications for bias, imprecision and other characteristics. Estimation of specifications required for reference change values is traditionally...... done using relationship between the batch-related changes during routine performance, described as Δbias, and the coefficients of variation for analytical imprecision (CVA): the original theory is based on standard deviations or coefficients of variation calculated as if distributions were Gaussian....... METHODS: The distribution of between-subject biological variation can generally be described as log-Gaussian. Moreover, recent analyses of within-subject biological variation suggest that many measurands have log-Gaussian distributions. In consequence, we generated a model for the estimation of analytical...

  12. Performance of the new Bayer VERSANT HCV RNA 3.0 assay for quantitation of hepatitis C virus RNA in plasma and serum: Conversion to international units and comparison with the Roche COBAS amplicor HCV monitor, version 2.0, assay

    NARCIS (Netherlands)

    Beld, Marcel; Sentjens, Roel; Rebers, Sjoerd; Weegink, Christine; Weel, Jan; Sol, Cees; Boom, René

    2002-01-01

    We have evaluated the VERSANT HCV RNA 3.0. Assay (HCV 3.0 bDNA assay) (Bayer Diagnostics, Berkeley, Calif.), which is an improved signal amplification procedure for the HCV 2.0 bDNA assay for the quantitation of hepatitis C virus (HCV) RNA in serum or plasma of HCV-infected individuals. The HCV 3.0

  13. Endogenous Locus Reporter Assays.

    Science.gov (United States)

    Liu, Yaping; Hermes, Jeffrey; Li, Jing; Tudor, Matthew

    2018-01-01

    Reporter gene assays are widely used in high-throughput screening (HTS) to identify compounds that modulate gene expression. Traditionally a reporter gene assay is built by cloning an endogenous promoter sequence or synthetic response elements in the regulatory region of a reporter gene to monitor transcriptional activity of a specific biological process (exogenous reporter assay). In contrast, an endogenous locus reporter has a reporter gene inserted in the endogenous gene locus that allows the reporter gene to be expressed under the control of the same regulatory elements as the endogenous gene, thus more accurately reflecting the changes seen in the regulation of the actual gene. In this chapter, we introduce some of the considerations behind building a reporter gene assay for high-throughput compound screening and describe the methods we have utilized to establish 1536-well format endogenous locus reporter and exogenous reporter assays for the screening of compounds that modulate Myc pathway activity.

  14. Knockdown of Ran GTPase expression inhibits the proliferation and migration of breast cancer cells.

    Science.gov (United States)

    Sheng, Chenyi; Qiu, Jian; Wang, Yingying; He, Zhixian; Wang, Hua; Wang, Qingqing; Huang, Yeqing; Zhu, Lianxin; Shi, Feng; Chen, Yingying; Xiong, Shiyao; Xu, Zhen; Ni, Qichao

    2018-05-03

    Breast cancer is the second leading cause of cancer‑associated mortality in women worldwide. Strong evidence has suggested that Ran, which is a small GTP binding protein involved in the transport of RNA and protein across the nucleus, may be a key cellular protein involved in the metastatic progression of cancer. The present study investigated Ran gene expression in breast cancer tissue samples obtained from 140 patients who had undergone surgical resection for breast cancer. Western blot analysis of Ran in breast cancer tissues and paired adjacent normal tissues showed that expression of Ran was significantly increased in breast cancer tissues. Immunohistochemistry analyses conducted on formalin‑fixed paraffin‑embedded breast cancer tissue sections revealed that Ran expression was associated with tumor histological grade, nerve invasion and metastasis, vascular metastasis and Ki‑67 expression (a marker of cell proliferation). Kaplan‑Meier survival analysis showed that increased Ran expression in patients with breast cancer was positively associated with a poor survival prognosis. Furthermore, in vitro experiments demonstrated that highly migratory MDA‑MB‑231 cancer cells treated with Ran‑si‑RNA (si‑Ran), which knocked down expression of Ran, exhibited decreased motility in trans‑well migration and wound healing assays. Cell cycle analysis of Ran knocked down MDA‑MB‑231 cells implicated Ran in cell cycle arrest and the inhibition of proliferation. Furthermore, a starvation and re‑feeding (CCK‑8) assay was performed, which indicated that Ran regulated breast cancer cell proliferation. Taken together, the results provide strong in vitro evidence of the involvement of Ran in the progression of breast cancer and suggest that it could have high potential as a therapeutic target and/or marker of disease.

  15. Knockdown of TFIIS by RNA silencing inhibits cancer cell proliferation and induces apoptosis

    International Nuclear Information System (INIS)

    Hubbard, Kyle; Catalano, Jennifer; Puri, Raj K; Gnatt, Averell

    2008-01-01

    A common element among cancer cells is the presence of improperly controlled transcription. In these cells, the degree of specific activation of some genes is abnormal, and altering the aberrant transcription may therefore directly target cancer. TFIIS is a transcription elongation factor, which directly binds the transcription motor, RNA Polymerase II and allows it to read through various transcription arrest sites. We report on RNA interference of TFIIS, a transcription elongation factor, and its affect on proliferation of cancer cells in culture. RNA interference was performed by transfecting siRNA to specifically knock down TFIIS expression in MCF7, MCF10A, PL45 and A549 cells. Levels of TFIIS expression were determined by the Quantigene method, and relative protein levels of TFIIS, c-myc and p53 were determined by C-ELISA. Induction of apoptosis was determined by an enzymatic Caspase 3/7 assay, as well as a non-enzymatic assay detecting cytoplasmic mono- and oligonucleosomes. A gene array analysis was conducted for effects of TFIIS siRNA on MCF7 and MCF10A cell lines. Knockdown of TFIIS reduced cancer cell proliferation in breast, lung and pancreatic cancer cell lines. More specifically, TFIIS knockdown in the MCF7 breast cancer cell line induced cancer cell death and increased c-myc and p53 expression whereas TFIIS knockdown in the non-cancerous breast cell line MCF10A was less affected. Differential effects of TFIIS knockdown in MCF7 and MCF10A cells included the estrogenic, c-myc and p53 pathways, as observed by C-ELISA and gene array, and were likely involved in MCF7 cell-death. Although transcription is a fundamental process, targeting select core transcription factors may provide for a new and potent avenue for cancer therapeutics. In the present study, knockdown of TFIIS inhibited cancer cell proliferation, suggesting that TFIIS could be studied as a potential cancer target within the transcription machinery

  16. Performance of a commercial assay for the diagnosis of influenza A (H1N1 infection in comparison to the Centers for Disease Control and Prevention protocol of real time RT-PCR

    Directory of Open Access Journals (Sweden)

    María G Barbás

    2012-03-01

    Full Text Available At the time of influenza A (H1N1 emergency, the WHO responded with remarkable speed by releasing guidelines and a protocol for a real-time RT-PCR assay (rRT-PCR. The aim of the present study was to evalúate the performance of the "Real Time Ready Influenza A/H1N1 Detection Set" (June 2009-Roche kit in comparison to the CDC reference rRT-PCR protocol. The overall sensitivity of the Roche assay for detection of the Inf A gene in the presence or absence of the H1 gene was 74.5 %. The sensitivity for detecting samples that were only positive for the Inf A gene (absence of the H1 gene was 53.3 % whereas the sensitivity for H1N1-positive samples (presence of the Inf A gene and any other swine gene was 76.4 %. The specificity of the assay was 97.1 %. A new version of the kit (November 2009 is now available, and a recent evaluation of its performance showed good sensitivity to detect pandemic H1N1 compared to other molecular assays.Durante la pandemia de influenza A (H1N1, la OMS recomendó algoritmos y protocolos de detección del virus mediante RT-PCR en tiempo real. El objetivo del presente estudio fue evaluar el desempeño del equipo que comercializa la empresa Roche, Real Time Ready Influenza A/H1N1 Detection Set (junio de 2009, en comparación con el protocolo de RT-PCR en tiempo real de los CDC. La sensibilidad global del ensayo de Roche para la detección del gen Inf A en presencia o ausencia del gen H1 fue 74,5 %. La sensibilidad para la detección de muestras positivas solo para el gen Inf A (ausencia del gen H1 fue 53,3 % y la sensibilidad para la detección de muestras positivas para H1N1 (presencia del gen Inf A y cualquier otro gen porcino fue 76,4 %. La especificidad fue 97,1 %. Existe una nueva versión del equipo (noviembre 2009 que, según se ha descrito, presenta buena sensibilidad en comparación con otros ensayos moleculares para detectar H1N1 pandémica.

  17. Andrographolide Enhances Proliferation and Prevents Dedifferentiation of Rabbit Articular Chondrocytes: An In Vitro Study

    Directory of Open Access Journals (Sweden)

    Li-ke Luo

    2015-01-01

    Full Text Available As the main active constituent of Andrographis paniculata that was applied in treatment of many diseases including inflammation in ancient China, andrographolide (ANDRO was found to facilitate reduction of edema and analgesia in arthritis. This suggested that ANDRO may be promising anti-inflammatory agent to relieve destruction and degeneration of cartilage after inflammation. In this study, the effect of ANDRO on rabbit articular chondrocytes in vitro was investigated. Results showed that not more than 8 μM ANDRO did no harm to chondrocytes (P0.05. The viability assay, hematoxylin-eosin, safranin O, and immunohistochemical staining also showed better performances in ANDRO groups. As to the doses, 3 μM ANDRO showed the best performance. The results indicate that ANDRO can accelerate proliferation of rabbit articular chondrocytes in vitro and meanwhile maintain the phenotype, which may provide valuable references for further exploration on arthritis.

  18. Thorium cycles and proliferation

    International Nuclear Information System (INIS)

    Lovins, A.B.

    1979-01-01

    This paper analyzes several prevalent misconceptions about nuclear fuel cycles that breed fissile uranium-233 from thorium. Its main conclusions are: U-233, despite the gamma radioactivity of associated isotopes, is a rather attractive material for making fission bombs, and is a credible material for subnational as well as national groups to use for this purpose; (2) pure thorium cycles, which in effect merely substitute U-233 for Pu, would take many decades and much U to establish, and offer no significant safeguards advantage over Pu, cycles; (3) denatured Th-U cycles, which dilute the U-233 with inert U-238 to a level not directly usable in bombs, are not an effective safeguard even against subnational bomb-making; (4) several other features of mixed Th-U cycles are rather unattractive from a safeguards point of view; (5) thus, Th cycles of any kind are not a technical fix for proliferation (national or subnational) and, though probably more safeguardable than Pu cycles, are less so than once-through U cycles that entail no reprocessing; (6) while thorium cycles have some potential technical advantages, including flexibility, they cannot provide major savings in nuclear fuel resources compared to simpler ways of saving neutrons and U; and (7) while advocates of nuclear power may find Th cycles worth exploring, such cycles do not differ fundamentally from U cycles in any of the respects--including safeguards and fuel resources--that are relevant to the broader nuclear debate, and should not be euphorically embraced as if they did

  19. Experience in non-proliferation verification: The Treaty of Raratonga

    International Nuclear Information System (INIS)

    Walker, R.A.

    1998-01-01

    The verification provisions of the Treaty of Raratonga are subdivided into two categories: those performed by IAEA and those performed by other entities. A final provision of the Treaty of Raratonga is relevant to IAEA safeguards according to support of the continued effectiveness of the international non-proliferation system based on the Non-proliferation Treaty and the IAEA safeguards system. The non-IAEA verification process is described as well

  20. Theoretical Approaches to Nuclear Proliferation

    Directory of Open Access Journals (Sweden)

    Konstantin S. Tarasov

    2015-01-01

    Full Text Available This article analyses discussions between representatives of three schools in the theory of international relations - realism, liberalism and constructivism - on the driving factors of nuclear proliferation. The paper examines major theoretical approaches, outlined in the studies of Russian and foreign scientists, to the causes of nuclear weapons development, while unveiling their advantages and limitations. Much of the article has been devoted to alternative approaches, particularly, the role of mathematical modeling in assessing proliferation risks. The analysis also reveals a variety of different approaches to nuclear weapons acquisition, as well as the absence of a comprehensive proliferation theory. Based on the research results the study uncovers major factors both favoring and impeding nuclear proliferation. The author shows that the lack of consensus between realists, liberals and constructivists on the nature of proliferation led a number of scientists to an attempt to explain nuclear rationale by drawing from the insights of more than one school in the theory of IR. Detailed study of the proliferation puzzle contributes to a greater understating of contemporary international realities, helps to identify mechanisms that are most likely to deter states from obtaining nuclear weapons and is of the outmost importance in predicting short- and long-term security environment. Furthermore, analysis of the existing scientific literature on nuclear proliferation helps to determine future research agenda of the subject at hand.

  1. ASSESSING THE PROLIFERATION RESISTANCE OF INNOVATIVE NUCLEAR FUEL CYCLES

    International Nuclear Information System (INIS)

    BARI, R.; ROGLANS, J.; DENNING, R.; MLADINEO, S.

    2003-01-01

    The National Nuclear Security Administration is developing methods for nonproliferation assessments to support the development and implementation of U.S. nonproliferation policy. This paper summarizes the key results of that effort. Proliferation resistance is the degree of difficulty that a nuclear material, facility, process, or activity poses to the acquisition of one or more nuclear weapons. A top-level measure of proliferation resistance for a fuel cycle system is developed here from a hierarchy of metrics. At the lowest level, intrinsic and extrinsic barriers to proliferation are defined. These barriers are recommended as a means to characterize the proliferation characteristics of a fuel cycle. Because of the complexity of nonproliferation assessments, the problem is decomposed into: metrics to be computed, barriers to proliferation, and a finite set of threats. The spectrum of potential threats of nuclear proliferation is complex and ranges from small terrorist cells to industrialized countries with advanced nuclear fuel cycles. Two general categories of methods have historically been used for nonproliferation assessments: attribute analysis and scenario analysis. In the former, attributes of the systems being evaluated (often fuel cycle systems) are identified that affect their proliferation potential. For a particular system under consideration, the attributes are weighted subjectively. In scenario analysis, hypothesized scenarios of pathways to proliferation are examined. The analyst models the process undertaken by the proliferant to overcome barriers to proliferation and estimates the likelihood of success in achieving a proliferation objective. An attribute analysis approach should be used at the conceptual design level in the selection of fuel cycles that will receive significant investment for development. In the development of a detailed facility design, a scenario approach should be undertaken to reduce the potential for design vulnerabilities

  2. Quantification of N-acetyl- and N-glycolylneuraminic acids by a stable isotope dilution assay using high-performance liquid chromatography-tandem mass spectrometry.

    Science.gov (United States)

    Allevi, Pietro; Femia, Eti Alessandra; Costa, Maria Letizia; Cazzola, Roberta; Anastasia, Mario

    2008-11-28

    The present report describes a method for the quantification of N-acetyl- and N-glycolylneuraminic acids without any derivatization, using their (13)C(3)-isotopologues as internal standards and a C(18) reversed-phase column modified by decylboronic acid which allows for the first time a complete chromatographic separation between the two analytes. The method is based on high-performance liquid chromatographic coupled with electrospray ion-trap mass spectrometry. The limit of quantification of the method is 0.1mg/L (2.0ng on column) for both analytes. The calibration curves are linear for both sialic acids over the range of 0.1-80mg/L (2.0-1600ng on column) with a correlation coefficient greater than 0.997. The proposed method was applied to the quantitative determination of sialic acids released from fetuin as a model of glycoproteins.

  3. Validation of a modification to Performance-Tested Method 010403: microwell DNA hybridization assay for detection of Listeria spp. in selected foods and selected environmental surfaces.

    Science.gov (United States)

    Alles, Susan; Peng, Linda X; Mozola, Mark A

    2009-01-01

    A modification to Performance-Tested Method 010403, GeneQuence Listeria Test (DNAH method), is described. The modified method uses a new media formulation, LESS enrichment broth, in single-step enrichment protocols for both foods and environmental sponge and swab samples. Food samples are enriched for 27-30 h at 30 degrees C, and environmental samples for 24-48 h at 30 degrees C. Implementation of these abbreviated enrichment procedures allows test results to be obtained on a next-day basis. In testing of 14 food types in internal comparative studies with inoculated samples, there were statistically significant differences in method performance between the DNAH method and reference culture procedures for only 2 foods (pasteurized crab meat and lettuce) at the 27 h enrichment time point and for only a single food (pasteurized crab meat) in one trial at the 30 h enrichment time point. Independent laboratory testing with 3 foods showed statistical equivalence between the methods for all foods, and results support the findings of the internal trials. Overall, considering both internal and independent laboratory trials, sensitivity of the DNAH method relative to the reference culture procedures was 90.5%. Results of testing 5 environmental surfaces inoculated with various strains of Listeria spp. showed that the DNAH method was more productive than the reference U.S. Department of Agriculture-Food Safety and Inspection Service (USDA-FSIS) culture procedure for 3 surfaces (stainless steel, plastic, and cast iron), whereas results were statistically equivalent to the reference method for the other 2 surfaces (ceramic tile and sealed concrete). An independent laboratory trial with ceramic tile inoculated with L. monocytogenes confirmed the effectiveness of the DNAH method at the 24 h time point. Overall, sensitivity of the DNAH method at 24 h relative to that of the USDA-FSIS method was 152%. The DNAH method exhibited extremely high specificity, with only 1% false

  4. Advanced glycation end products promote ChREBP expression and cell proliferation in liver cancer cells by increasing reactive oxygen species.

    Science.gov (United States)

    Chen, Hanbei; Li, Yakui; Zhu, Yemin; Wu, Lifang; Meng, Jian; Lin, Ning; Yang, Dianqiang; Li, Minle; Ding, WenJin; Tong, Xuemei; Su, Qing

    2017-08-01

    The aim of the study was to elucidate the mechanism by which advanced glycation end products (AGEs) promote cell proliferation in liver cancer cells.We treated liver cancer HepG2 cells with 200 mg/L AGEs or bovine serum albumin (BSA) and assayed for cell viability, cell cycle, and apoptosis. We performed real-time PCR and Western blot analysis for RNA and protein levels of carbohydrate responsive element-binding protein (ChREBP) in AGEs- or BSA-treated HepG2 cells. We analyzed the level of reactive oxygen species (ROS) in HepG2 cells treated with AGEs or BSA.We found that increased S-phase cell percentage and decreased apoptosis contributed to AGEs-induced liver cancer cell proliferation. Real-time PCR and Western blot analysis showed that AGEs stimulated RNA and protein levels of ChREBP, a transcription factor promoting glycolysis and maintaining cell proliferation in liver cancer cells. Intriguingly, the level of ROS was higher in AGEs-treated liver cancer cells. Treating liver cancer cells with antioxidant N-acetyl cystein (NAC) partly blocked AGEs-induced ChREBP expression and cell proliferation.Our results suggest that the AGEs-ROS-ChREBP pathway plays a critical role in promoting ChREBP expression and liver cancer cell proliferation.

  5. Nuclear non proliferation and disarmament

    International Nuclear Information System (INIS)

    2000-01-01

    In the framework of the publication of a document on the ''weapons mastership, disarmament and non proliferation: the french action'', by the ministry of Foreign Affairs and the ministry of Defense, the French Documentation organization presents a whole document. This document describes and details the following topics: the conference on the treaty of non proliferation of nuclear weapons, the France, Usa and Non Governmental Organizations position, the threats of the proliferation, the french actions towards the disarmament, the disarmament in the world, a chronology and some bibliographic resources. (A.L.B.)

  6. International proliferation on nuclear weapons

    International Nuclear Information System (INIS)

    Hill, J.

    1977-01-01

    The subject is dealt with under the following headings: introduction; routes to proliferation (preparation of U 235 , Pu 239 , U 233 ); nuclear power fuel cycles and proliferation; the fast reactor fuel cycle; security aspects of the existing fuel cycle; the IAEA and the nuclear non-proliferation treaty. It is concluded that 'the basis for sound international control exists, and taken together with the further technical steps which will be taken to make the existing fuel cycles more robust against the diversion of materials by terrorists and the abuse of civil nuclear power programmes by governments, we have good reason to proceed now with the orderly exploitation of ...nuclear energy...'. (U.K.)

  7. TRB3 is elevated in psoriasis vulgaris lesions and mediates HaCaT cells proliferation in vitro.

    Science.gov (United States)

    Yu, Xiao-Jing; Song, Tie-Jun; Zhang, Lu-Wei; Su, Ying; Wang, Ke-Yu; Sun, Qing

    2017-10-01

    Psoriasis is a chronic skin disease characterized by abnormal keratinocyte proliferation and differentiation, inflammation, and angiogenesis. Overexpression of tribbles homolog3 (TRB3), which belongs to the tribbles family of pseudokinases, has been found in several human tumors and metabolic diseases, but its role in psoriasis has not been fully clarified. The aim of this study is to investigate the expression of TRB3 in psoriasis and explore its roles in the proliferation of keratinocytes. Twenty-four patients with psoriasis vulgaris were recruited for the study. Diagnosis of psoriasis was based on clinical and histologic examinations. Immunohistochemistry and real-time reverse transcription PCR (RT-PCR) were performed to determine protein and messenger RNA (mRNA) expression of TRB3 in psoriasis lesions. 5-Bromo-2-deoxyUridine (BrdU) incorporation assay were performed for cell proliferation. Cell cycle distribution was assessed by flow cytometry analysis. The levels of TRB3 is elevated in psoriatic lesions compared with psoriatic non-lesions. The HaCat cells expressed the TRB3 gene. We found TRB3 silencing to significantly inhibit HaCat cell proliferation. Furthermore, the specific knockdown of TRB3 slowed down the cell cycle at the gap 0/first gap phase. In conclusion, our data suggest that TRB3 is overexpressed in lesions of patients with psoriasis and may be involved in the abnormal proliferation of keratinocytes. Therefore, TRB3 may be a potential therapeutic target for psoriasis. © American Federation for Medical Research (unless otherwise stated in the text of the article) 2017. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  8. Metformin Induces Cell Cycle Arrest, Reduced Proliferation, Wound Healing Impairment In Vivo and Is Associated to Clinical Outcomes in Diabetic Foot Ulcer Patients.

    Science.gov (United States)

    Ochoa-Gonzalez, Fatima; Cervantes-Villagrana, Alberto R; Fernandez-Ruiz, Julio C; Nava-Ramirez, Hilda S; Hernandez-Correa, Adriana C; Enciso-Moreno, Jose A; Castañeda-Delgado, Julio E

    2016-01-01

    Several epidemiological studies in diabetic patients have demonstrated a protective effect of metformin to the development of several types of cancer. The underlying mechanisms of such phenomenon is related to the effect of metformin on cell proliferation among which, mTOR, AMPK and other targets have been identified. However, little is known about the role that metformin treatment have on other cell types such as keratinocytes and whether exposure to metformin of these cells might have serious repercussions in wound healing delay and in the development of complications in diabetic patients with foot ulcers or in their exacerbation. HaCaT Cells were exposed to various concentrations of metformin and cell viability was evaluated by a Resazurin assay; Proliferation was also evaluated with a colony formation assay and with CFSE dilution assay by flow cytometry. Cell cycle was also evaluated by flow cytometry by PI staining. An animal model of wound healing was used to evaluate the effect of metformin in wound closure. Also, an analysis of patients receiving metformin treatment was performed to determine the effect of metformin treatment on the outcome and wound area. Statistical analysis was performed on SPSS v. 18 and GraphPad software v.5. Metformin treatment significantly reduces cell proliferation; colony formation and alterations of the cell cycle are observed also in the metformin treated cells, particularly in the S phase. There is a significant increase in the area of the wound of the metformin treated animals at different time points (Pdiabetic foot ulcers at the time of hospitalization. A protective effect of metformin was observed for amputation, probably associated with the anti inflammatory effects reported of metformin. Metformin treatment reduces cell proliferation and reduces wound healing in an animal model and affects clinical outcomes in diabetic foot ulcer patients. Chronic use of this drug should be further investigated to provide evidence of

  9. Bio-active molecules modified surfaces enhanced mesenchymal stem cell adhesion and proliferation

    International Nuclear Information System (INIS)

    Mobasseri, Rezvan; Tian, Lingling; Soleimani, Masoud; Ramakrishna, Seeram; Naderi-Manesh, Hossein

    2017-01-01

    Surface modification of the substrate as a component of in vitro cell culture and tissue engineering, using bio-active molecules including extracellular matrix (ECM) proteins or peptides derived ECM proteins can modulate the surface properties and thereby induce the desired signaling pathways in cells. The aim of this study was to evaluate the behavior of human bone marrow mesenchymal stem cells (hBM-MSCs) on glass substrates modified with fibronectin (Fn), collagen (Coll), RGD peptides (RGD) and designed peptide (R-pept) as bio-active molecules. The glass coverslips were coated with fibronectin, collagen, RGD peptide and R-peptide. Bone marrow mesenchymal stem cells were cultured on different substrates and the adhesion behavior in early incubation times was investigated using scanning electron microscopy (SEM) and confocal microscopy. The MTT assay was performed to evaluate the effect of different bio-active molecules on MSCs proliferation rate during 24 and 72 h. Formation of filopodia and focal adhesion (FA) complexes, two steps of cell adhesion process, were observed in MSCs cultured on bio-active molecules modified coverslips, specifically in Fn coated and R-pept coated groups. SEM image showed well adhesion pattern for MSCs cultured on Fn and R-pept after 2 h incubation, while the shape of cells cultured on Coll and RGD substrates indicated that they might experience stress condition in early hours of culture. Investigation of adhesion behavior, as well as proliferation pattern, suggests R-peptide as a promising bio-active molecule to be used for surface modification of substrate in supporting and inducing cell adhesion and proliferation. - Highlights: • Bioactive molecules modified surface is a strategy to design biomimicry scaffold. • Bi-functional Tat-derived peptide (R-pept) enhanced MSCs adhesion and proliferation. • R-pept showed similar influences to fibronectin on FA formation and attachment.

  10. Systematic review with meta-analysis: diagnostic performance of the combination of pepsinogen, gastrin-17 and anti-Helicobacter pylori antibodies serum assays for the diagnosis of atrophic gastritis.

    Science.gov (United States)

    Zagari, R M; Rabitti, S; Greenwood, D C; Eusebi, L H; Vestito, A; Bazzoli, F

    2017-10-01

    The combination of pepsinogen, gastrin-17 and anti-H. pylori antibodies serological assays (panel test) is a non-invasive tool for the diagnosis of atrophic gastritis. However, the diagnostic reliability of this test is still uncertain. To assess the diagnostic performance of the serum panel test for the diagnosis of atrophic gastritis. Medline via PubMed, Embase, Scopus, Cochrane Library databases and abstracts of international conferences proceedings were searched from January 1995 to December 2016 using the primary keywords "pepsinogens," "gastrin," "atrophic gastritis," "gastric precancerous lesions." Studies were included if they assessed the accuracy of the serum panel test for the diagnosis of atrophic gastritis using histology according to the updated Sydney System as reference standard. Twenty studies with a total of 4241 subjects assessed the performance of serum panel test for the diagnosis of atrophic gastritis regardless of the site in the stomach. The summary sensitivity was 74.7% (95% confidence interval (CI), 62.0-84.3) and the specificity was 95.6% (95%CI, 92.6-97.4). With a prevalence of atrophic gastritis of 27% (median prevalence across the studies), the negative predictive value was 91%. Few studies with small sample size assessed the performance of the test in detecting the site of atrophic gastritis. The combination of pepsinogen, gastrin-17 and anti-H. pylori antibodies serological assays appears to be a reliable tool for the diagnosis of atrophic gastritis. This test may be used for screening subjects or populations at high risk of gastric cancer for atrophic gastritis; however, a cost-effectiveness analysis is needed. © 2017 John Wiley & Sons Ltd.

  11. Alkyl-fluorinated thymidine derivatives for imaging cell proliferation

    International Nuclear Information System (INIS)

    Toyohara, Jun; Hayashi, Akio; Gogami, Akie; Hamada, Masahiro; Hamashima, Yoshio; Katoh, Takahiro; Node, Manabu; Fujibayashi, Yasuhisa

    2006-01-01

    Derivatives of 2'-deoxyuridine that contain fluoroalkyl groups at the C5 position and derivatives of thymidine that contain fluoroalkyl groups at the N3 position were synthesized and examined in three in vitro assays designed to evaluate their potential as radiopharmaceuticals for imaging cellular proliferation. Three of the former nucleosides and five of the latter were synthesized. The three assays were as follows: (a) phosphoryl transfer assay, which showed that all three of the former nucleosides and four of the latter ones were phosphorylated by recombinant human thymidine kinase 1 (TK1) and that N 3 -(2-fluoroethyl)-thymidine (NFT202) was the most potent substrate of the eight nucleosides studied; (b) transport assay, which indicated that all eight nucleosides had good affinity for an 6-[(4-nitrobenzyl)thio]-9-β-D-ribofuranosylpurine-sensitive mouse erythrocyte nucleoside transporter, with inhibition constants in the range of 0.02-0.55 mM; and (c) degradation assay, which showed that all but one of the former nucleosides and none of the latter were degraded by recombinant Escherichia coli thymidine phosphorylase (an enzyme that catalyzes the glycosidic bond of thymidine and 2'-deoxyuridine derivatives). From these in vitro screening assays, we selected NFT202 as a candidate for subsequent in vivo evaluation because this compound met the three minimum requirements of the in vitro screening assays and had the most potent phosphorylation activity as a substrate for recombinant human TK1

  12. Determination and validation of a simple high-performance liquid chromatographic method for simultaneous assay of iprodione and vinclozolin in human urine.

    Science.gov (United States)

    Carlucci, Giuseppe; Pasquale, Dorina Di; Ruggieri, Fabrizio; Mazzeo, Pietro

    2005-12-15

    A method based on solid-phase extraction (SPE) and high-performance liquid chromatography (HPLC) was developed for the simultaneous determination of 3-(3,5-diclorophenyl)-5-ethenyl-5-methyl-2,4-oxazolidinedione (vinclozolin) and 3-(3,5-diclorophenyl)-N-(1-methylethyl)-2,4-dioxo-1-imidazolidinecarboxamide (iprodione) in human urine. Urine samples containing vinclozolin and iprodione were collected by solid phase extraction using C(18) cartridges. The chromatographic separation was achieved on a Spherisorb ODS2 (250 mm x 4.6 mm, 5 microm) column with an isocratic mobile phase of acetonitrile-water (60:40, v/v). Detection was UV absorbance at 220 nm. The calibration graphs were linear from 30 to 1000 ng/mL for the two fungicides. Intra- and inter-day R.S.D. did not exceed 2.9%. The quantitation limit was 50 ng/mL for vinclozolin and 30 ng/mL for iprodione, respectively.

  13. Factor IX assay

    Science.gov (United States)

    ... this page: //medlineplus.gov/ency/article/003679.htm Factor IX assay To use the sharing features on ... M. is also a founding member of Hi-Ethics and subscribes to the principles of the Health ...

  14. Factor VIII assay

    Science.gov (United States)

    ... this page: //medlineplus.gov/ency/article/003678.htm Factor VIII assay To use the sharing features on ... M. is also a founding member of Hi-Ethics and subscribes to the principles of the Health ...

  15. Factor II assay

    Science.gov (United States)

    ... this page: //medlineplus.gov/ency/article/003674.htm Factor II assay To use the sharing features on ... M. is also a founding member of Hi-Ethics and subscribes to the principles of the Health ...

  16. Factor VII assay

    Science.gov (United States)

    ... this page: //medlineplus.gov/ency/article/003676.htm Factor VII assay To use the sharing features on ... M. is also a founding member of Hi-Ethics and subscribes to the principles of the Health ...

  17. Microbead agglutination based assays

    KAUST Repository

    Kodzius, Rimantas; Castro, David; Foulds, Ian G.; Parameswaran, Ash M.; Sumanpreet, K. Chhina

    2013-01-01

    We report a simple and rapid room temperature assay for point-of-care (POC) testing that is based on specific agglutination. Agglutination tests are based on aggregation of microbeads in the presence of a specific analyte thus enabling

  18. Non-proliferation and nuclear data

    International Nuclear Information System (INIS)

    Sowerby, M.G.

    1978-01-01

    A review is made of the problem of the proliferation of nuclear weapons with particular emphasis on proliferation and nuclear power. Some indications of the nuclear data requirements associated with methods of reducing proliferation risks are presented

  19. Automation of the dicentric chromosome assay and related assays

    International Nuclear Information System (INIS)

    Balajee, Adayabalam S.; Dainiak, Nicholas

    2016-01-01

    Dicentric Chromosome Assay (DCA) is considered to be the 'gold standard' for personalized dose assessment in humans after accidental or incidental radiation exposure. Although this technique is superior to other cytogenetic assays in terms of specificity and sensitivity, its potential application to radiation mass casualty scenarios is highly restricted because DCA is time consuming and labor intensive when performed manually. Therefore, it is imperative to develop high throughput automation techniques to make DCA suitable for radiological triage scenarios. At the Cytogenetic Biodosimetry Laboratory in Oak Ridge, efforts are underway to develop high throughput automation of DCA. Current status on development of various automated cytogenetic techniques in meeting the biodosimetry needs of radiological/nuclear incident(s) will be discussed

  20. Lymphocyte proliferation to mycobacterial antigens is detectable across a spectrum of HIV-associated tuberculosis

    Directory of Open Access Journals (Sweden)

    Bakari Muhammad

    2009-02-01

    Full Text Available Abstract Background Identifying novel TB diagnostics is a major public health priority. We explored the diagnostic characteristics of antimycobacterial lymphocyte proliferation assays (LPA in HIV-infected subjects with latent or active TB. Methods HIV-infected subjects with bacille Calmette Guérin (BCG scars and CD4 counts ≥ 200 cells/mm3 entering a TB booster vaccine trial in Tanzania had baseline in vivo and in vitro immune tests performed: tuberculin skin tests (TST, LPA and five day assays of interferon gamma (IFN-γ release. Assay antigens were early secreted antigenic target 6 (ESAT-6, antigen 85 (Ag85, and Mycobacterium tuberculosis whole cell lysate (WCL. Subjects were screened for active TB at enrollment by history, exam, sputum smear and culture. We compared antimycobacterial immune responses between subjects with and without latent or active TB at enrollment. Results Among 1885 subjects screened, 635 had latent TB and 13 had active TB. Subjects with latent TB were more likely than subjects without TB to have LPA responses to ESAT-6 (13.2% vs. 5.5%, P Conclusion Lymphoproliferative responses to mycobacteria are detectable during HIV-associated active TB, and are less sensitive but more specific than TST. Trial registration ClinicalTrials.gov Identifier NCT00052195.

  1. The effect of insulin, TNFα and DHA on the proliferation, differentiation and lipolysis of preadipocytes isolated from large yellow croaker (Pseudosciaena Crocea R.).

    Science.gov (United States)

    Wang, Xinxia; Huang, Ming; Wang, Yizhen

    2012-01-01

    Fish final product can be affected by excessive lipid accumulation. Therefore, it is important to develop strategies to control obesity in cultivated fish to strengthen the sustainability of the aquaculture industry. As in mammals, the development of adiposity in fish depends on hormonal, cytokine and dietary factors. In this study, we investigated the proliferation and differentiation of preadipocytes isolated from the large yellow croaker and examined the effects of critical factors such as insulin, TNFα and DHA on the proliferation, differentiation and lipolysis of adipocytes. Preadipocytes were isolated by collagenase digestion, after which their proliferation was evaluated. The differentiation process was optimized by assaying glycerol-3-phosphate dehydrogenase (GPDH) activity. Oil red O staining and electron microscopy were performed to visualize the accumulated triacylglycerol. Gene transcript levels were measured using SYBR green quantitative real-time PCR. Insulin promoted preadipocytes proliferation, stimulated cell differentiation and decreased lipolysis of mature adipocytes. TNFα and DHA inhibited cell proliferation and differentiation. While TNFα stimulated mature adipocyte lipolysis, DHA showed no lipolytic effect on adipocytes. The expressions of adipose triglyceride lipase (ATGL), fatty acid synthase (FAS), lipoprotein lipase (LPL) and peroxisome proliferator-activated receptor α, γ (PPARα, PPARγ) were quantified during preadipocytes differentiation and adipocytes lipolysis to partly explain the regulation mechanisms. In summary, the results of this study indicated that although preadipocytes proliferation and the differentiation process in large yellow croaker are similar to these processes in mammals, the effects of critical factors such as insulin, TNFα and DHA on fish adipocytes development are not exactly the same. Our findings fill in the gaps in the basic data regarding the effects of critical factors on adiposity development in fish

  2. Future technology challenges in non-proliferation

    International Nuclear Information System (INIS)

    Richardson, J.H.

    2004-01-01

    Radiation detection technologies are an important tool in the prevention of proliferation. A variety of new developments have enabled enhanced performance in terms of energy resolution, spatial resolution, predictive modeling and simulation, active interrogation, and ease of operation and deployment in the field. For example, various gamma ray imaging approaches are being explored to combine spatial resolution with background suppression in order to enhance sensitivity at reasonable standoff distances and acquisition times. New materials and approaches are being developed in order to provide adequate energy resolution in field use without the necessity for liquid nitrogen. Finally, different detectors combined into distributed networks offer promise for detection and tracking of radioactive materials. As the world moves into the 21st century, the possibility of greater reliance on nuclear energy will impose additional technical requirements to prevent proliferation. In addition to proliferation resistant reactors, a careful examination of the various possible fuel cycles from cradle to grave will provide additional technical and nonproliferation challenges in the areas of conversion, enrichment, transportation, recycling and waste disposal. Radiation detection technology and information management have a prominent role in any future global regime for nonproliferation beyond the current Advanced Protocol. This work was performed under the auspices of the U.S. Department of Energy by University of California, Lawrence Livermore National Laboratory under contract No. W-7405-Eng-48. (author)

  3. Fisetin regulates astrocyte migration and proliferation in vitro

    Science.gov (United States)

    Wang, Nan; Yao, Fang; Li, Ke; Zhang, Lanlan; Yin, Guo; Du, Mingjun; Wu, Bingyi

    2017-01-01

    Fisetin (3,3′,4′,7-tetrahydroxyflavone) is a plant flavonol found in fruits and vegetables that has been reported to inhibit migration and proliferation in several types of cancer. Reactive astrogliosis involves astrocyte migration and proliferation, and contributes to the formation of glial scars in central nervous system (CNS) disorders. However, the effect of fisetin on the migration and proliferation of astrocytes remains unclear. In this study, we found that fisetin inhibited astrocyte migration in a scratch-wound assay and diminished the phosphorylation of focal adhesion kinase (FAK; Tyr576/577 and paxillin (Tyr118). It also suppressed cell proliferation, as indicated by the decreased number of 5-ethynyl-2′-deoxyuridine (EdU)-positive cells, induced cell cycle arrest in the G1 phase, reduced the percentage of cells in the G2 and S phase (as measured by flow cytometry), and decreased cyclin D1 expression, but had no effect on apoptosis. Fisetin also decreased the phosphorylation levels of Akt and extracellular signal-regulated kinase (Erk)1/2, but had no effect on the phosphorylation of p38 mitogen-activated protein kinase (MAPK). These results indicate that fisetin inhibits aggressive cell phenotypes by suppressing cell migration and proliferation via the Akt/Erk signaling pathway. Fisetin may thus have potential for use as a therapeutic strategy targeting reactive astrocytes, which may lead to the inhibition of glial scar formation in vitro. PMID:28204814

  4. Nondestructive assay of sale materials

    International Nuclear Information System (INIS)

    Rodenburg, W.W.; Fleissner, J.G.

    1981-01-01

    This paper covers three primary areas: (1) reasons for performing nondestructive assay on SALE materials; (2) techniques used; and (3) discussion of investigators' revised results. The study shows that nondestructive calorimetric assay of plutonium offers a viable alternative to traditional wet chemical techniques. For these samples, the precision ranged from 0.4 to 0.6% with biases less than 0.2%. Thus, for those materials where sampling errors are the predominant source of uncertainty, this technique can provide improved accuracy and precision while saving time and money as well as reducing the amount of liquid wastes to be handled. In addition, high resolution gamma-ray spectroscopy measurements of solids can provide isotopic analysis data in a cost effective and timely manner. The timeliness of the method can be especially useful to the plant operator for production control and quality control measurements

  5. HCV core protein-induced down-regulation of microRNA-152 promoted aberrant proliferation by regulating Wnt1 in HepG2 cells.

    Directory of Open Access Journals (Sweden)

    Shifeng Huang

    Full Text Available Hepatitis C virus (HCV has been reported to regulate cellular microRNAs (miRNAs. The HCV core protein is considered to be a potential oncoprotein in HCV-related hepatocellular carcinoma (HCV-HCC, but HCV core-regulated miRNAs are largely unknown. Our preliminary experiments revealed significant down-regulation of microRNA-152 (miR-152 by HCV core protein in HepG2 cells. Through target gene prediction softwares, Wnt1 was predicted to be a potential target of miR-152. The present study was initiated to investigate whether miR-152 is aberrantly regulated by the HCV core protein, and involved in the regulation of the aberrant proliferation of HCV-HCC cells.MiR-152 levels were examined by stem-loop real-time RT-PCR (SLqRT-PCR. Cell proliferation was analyzed by MTT and colony formation assay. Cell cycle analysis was performed by flow cytometry. Luciferase reporter assay was conducted to confirm miRNA-target association. Wnt1 expression was determined by real-time qPCR and Western blotting.HCV core protein significantly suppressed miR-152 expression, and led to significant Wnt1 up-regulation with a concomitant aberrantly promoted proliferation. Moreover, we validated that miR-152 inhibition promoted, while miR-152 mimics inhibited cell proliferation. Using, qRT-PCR and western blot, Wnt1 was demonstrated to be regulated by miR-152. Luciferase activity assay showed that while miR-152 mimics significantly reduced the luciferase activity by 83.76% (P<0.0001, miR-152 inhibitor showed no effect on luciferase reporter. Most notably, salvage expression of miR-152 after Ad-HCV core infection for 24 h almost totally reversed the proliferation-promoting effect of the HCV core protein, and meanwhile, reduced the expression of both Wnt1 mRNA and protein to basal levels.These findings provide important evidence that the reduced miR-152 expression by HCV core protein can indirectly lose an inhibitory effect on Wnt1, which might, at least partially lead to cell

  6. Effects of currently used pesticides in assays for estrogenicity, androgenicity, and aromatase activity in vitro

    DEFF Research Database (Denmark)

    Andersen, Helle Raun; Vinggaard, Anne; Rasmussen, Thomas Høj

    2002-01-01

    , chlorpyrifos, deltamethrin, tolclofos-methyl, and tribenuron-methyl induced weak responses in one or both estrogenicity assays. Upon cotreatment with 17beta-estradiol, the response was potentiated by endosulfan in the proliferation assay and by pirimicarb, propamocarb, and daminozid in the ER transactivation...

  7. Enzymatically crosslinked gelatin hydrogel promotes the proliferation of adipose tissue-derived stromal cells

    Directory of Open Access Journals (Sweden)

    Gang Yang

    2016-09-01

    Full Text Available Gelatin hydrogel crosslinked by microbial transglutaminase (mTG exhibits excellent performance in cell adhesion, proliferation, and differentiation. We examined the gelation time and gel strength of gelatin/mTG hydrogels in various proportions to investigate their physical properties and tested their degradation performances in vitro. Cell morphology and viability of adipose tissue-derived stromal cells (ADSCs cultured on the 2D gel surface or in 3D hydrogel encapsulation were evaluated by immunofluorescence staining. Cell proliferation was tested via Alamar Blue assay. To investigate the hydrogel effect on cell differentiation, the cardiac-specific gene expression levelsof Nkx2.5, Myh6, Gja1, and Mef2c in encapsulated ADSCs with or without cardiac induction medium were detected by real-time RT-PCR. Cell release from the encapsulated status and cell migration in a 3D hydrogel model were assessed in vitro. Results show that the gelatin/mTG hydrogels are not cytotoxic and that their mechanical properties are adjustable. Hydrogel degradation is related to gel concentration and the resident cells. Cell growth morphology and proliferative capability in both 2D and 3D cultures were mainly affected by gel concentration. PCR result shows that hydrogel modulus together with induction medium affects the cardiac differentiation of ADSCs. The cell migration experiment and subcutaneous implantation show that the hydrogels are suitable for cell delivery.

  8. Future non-proliferation challenges

    International Nuclear Information System (INIS)

    Yelchenko, Volodymyr

    2008-01-01

    Having chaired the Second Session of the Preparatory Committee Mr. Volodymyr Yelchenko noted that the NPT States parties reaffirmed the important role of the Treaty as the cornerstone of the global non-proliferation regime. They stressed that non-compliance with the Treaty provisions by States parties undermined non-proliferation and placed emphasis on the mutually reinforcing nature of disarmament and non-proliferation, and due respect for the right of States parties to the peaceful use of nuclear energy in conformity with the treaty. They reaffirmed the importance of promoting the peaceful uses of nuclear energy and international nuclear cooperation for peaceful purposes in ways consistent with the non-proliferation goal of the Treaty. The universality aspect was brought to the front with the lack of progress in this area. States parties called upon India, Israel and Pakistan to accede to the Treaty as non-nuclear-weapons states, promptly and without conditions and to bring into force comprehensive safeguards agreements, together with Additional Protocols, for ensuring non-proliferation. There is concern that non-States actors could gain access to weapons of mass destruction. One of the underlying themes at the Second Prepcom was the total elimination of nuclear weapons as the only absolute guarantee against their proliferation. Negative consequences to nuclear non-proliferation were also mentioned in the context of the abrogation of the Anti-Ballistic Missile Treaty and the development of missile defense systems, with the risk of a new arms race on Earth and in outer space. The importance of the immediate commencement of negotiations in the Conference of Disarmament on a treaty concerning fissile material for nuclear weapons or other nuclear explosive devices and the urgent conclusion of such a treaty as a beneficial step towards non-proliferation was stressed. The NPT states parties reaffirmed the role of the IAEA as the sole competent authority responsible for

  9. H2A/K pseudogene mutation may promote cell proliferation

    Energy Technology Data Exchange (ETDEWEB)

    Guo, Jisheng; Jing, Ruirui; Lv, Xin; Wang, Xiaoyue; Li, Junqiang; Li, Lin; Li, Cuiling; Wang, Daoguang; Bi, Baibing; Chen, Xinjun [Cancer Research Center, Shandong University School of Medicine, Jinan 250012 (China); Yang, Jing-Hua, E-mail: sdu_crc_group1@126.com [Cancer Research Center, Shandong University School of Medicine, Jinan 250012 (China); Department of Surgery, VA Boston Healthcare System, Boston University School of Medicine, Boston 510660, MA (United States)

    2016-05-15

    Highlights: • The mutant H2A/K pseudogene is active. • The mutant H2A/K pseudogene can promote cell proliferation. - Abstract: Little attention has been paid to the histone H2A/K pseudogene. Results from our laboratory showed that 7 of 10 kidney cancer patients carried a mutant H2A/K pseudogene; therefore, we were interested in determining the relationship between mutant H2A/K and cell proliferation. We used shotgun and label-free proteomics methods to study whether mutant H2A/K lncRNAs affected cell proliferation. Quantitative proteomic analysis indicated that the expression of mutant H2A/K lncRNAs resulted in the upregulation of many oncogenes, which promoted cell proliferation. Further interaction analyses revealed that a proliferating cell nuclear antigen (PCNA)-protein interaction network, with PCNA in the center, contributes to cell proliferation in cells expressing the mutant H2A/K lncRNAs. Western blotting confirmed the critical upregulation of PCNA by mutant H2A/K lncRNA expression. Finally, the promotion of cell proliferation by mutant H2A/K lncRNAs (C290T, C228A and A45G) was confirmed using cell proliferation assays. Although we did not determine the exact mechanism by which the oncogenes were upregulated by the mutant H2A/K lncRNAs, we confirmed that the mutant H2A/K lncRNAs promoted cell proliferation by upregulating PCNA and other oncogenes. The hypothesis that cell proliferation is promoted by the mutant H2A/K lncRNAs was supported by the protein expression and cell proliferation assay results. Therefore, mutant H2A/K lncRNAs may be a new factor in renal carcinogenesis.

  10. The Role of RhoA, RhoB and RhoC GTPases in Cell Morphology, Proliferation and Migration in Human Cytomegalovirus (HCMV Infected Glioblastoma Cells

    Directory of Open Access Journals (Sweden)

    Melpomeni Tseliou

    2016-01-01

    Full Text Available Background/Aims: Rho GTPases are crucial regulators of the actin cytoskeleton, membrane trafficking and cell signaling and their importance in cell migration and invasion is well- established. The human cytomegalovirus (HCMV is a widespread pathogen responsible for generally asymptomatic and persistent infections in healthy people. Recent evidence indicates that HCMV gene products are expressed in over 90% of malignant type glioblastomas (GBM. In addition, the HCMV Immediate Early-1 protein (IE1 is expressed in >90% of tumors analyzed. Methods: RhoA, RhoB and RhoC were individually depleted in U373MG glioblastoma cells as well as U373MG cells stably expressing the HCMV IE1 protein (named U373MG-IE1 cells shRNA lentivirus vectors. Cell proliferation assays, migration as well as wound-healing assays were performed in uninfected and HCMV-infected cells. Results: The depletion of RhoA, RhoB and RhoC protein resulted in significant alterations in the morphology of the uninfected cells, which were further enhanced by the cytopathic effect caused by HCMV. Furthermore, in the absence or presence of HCMV, the knockdown of RhoB and RhoC proteins decreased the proliferation rate of the parental and the IE1-expressing glioblastoma cells, whereas the knockdown of RhoA protein in the HCMV infected cell lines restored their proliferation rate. In addition, wound healing assays in U373MG cells revealed that depletion of RhoA, RhoB and RhoC differentially reduced their migration rate, even in the presence or the absence of HCMV. Conclusion: Collectively, these data show for the first time a differential implication of Rho GTPases in morphology, proliferation rate and motility of human glioblastoma cells during HCMV infection, further supporting an oncomodulatory role of HCMV depending on the Rho isoforms' state.

  11. The importance of the nuclear glutathione in the Cell Proliferation

    OpenAIRE

    Markovic, Jelena

    2009-01-01

    The present thesis offers an insight in the importance of nuclear GSH in cell proliferation. The research was performed in three different cellular models of diverse proliferating activity: immortalized mouse embryonic fibroblasts 3T3, mammary adenocarcinoma cell line MCF7 and primary embryonic neuralonal culture. The results presented here provide evidence that suggest that the relationship between GSH level and telomerase activity, previously described by our group for 3T3 fibroblasts is a ...

  12. Novel T lymphocyte proliferation assessment using whole mouse cryo-imaging

    Science.gov (United States)

    Wuttisarnwattana, Patiwet; Raza, Syed A.; Eid, Saada; Cooke, Kenneth R.; Wilson, David L.

    2014-03-01

    New imaging technologies enable one to assess T-cell proliferation, an important feature of the immunological response. However, none of the traditional imaging modalities allow one to examine quantiatively T-cell function with microscopic resolution and single cell sensitivity over an entire mouse. To address this need, we established T-cells proliferation assays using 3D microscopic cryo-imaging. Assays include: (1) biodistribution of T-cells, (2) secondary lymphoid organ (SLO) volume measurement, (3) carboxyfluorescein succinimidyl ester (CFSE) dilution per cell as cells divide. To demonstrate the application, a graft-versus-host-disease (GVHD) model was used. 3D visualization show that T-cells specifically homed to the SLOs (spleen and lymph nodes) as well as GVHD target organs (such as GI-tract, liver, skin and thymus).The spleen was chosen as representative of the SLOs. For spleen size analysis, volumes of red and white pulp were measured. Spleen volumes of the allogeneic mice (with GVHD) were significantly larger than those of the syngeneic mice (without GVHD) at 72 to 120 hours post-transplant. For CFSE dilution approach, we employed color-coded volume rendering and probability density function (PDF) of single cell intensity to assess T-cell proliferation in the spleen. As compared to syngeneic T-cells, the allogeneic T-cells quickly aggregated in the spleen as indicated by increasing of CFSE signal over the first 48 hours. Then they rapidly proliferated as evidenced by reduced CFSE intensity (at 48-96 hours). Results suggest that assays can be used to study GVHD treatments using T-cell proliferation and biodistibution as assays. In summary, this is the first time that we are able to track and visualize T-cells in whole mouse with single cell sensitivity. We believe that our technique can be an alternative choice to traditional in vitro immunological proliferation assays by providing assessment of proliferation in an in vivo model.

  13. Radioreceptor assay for insulin

    Energy Technology Data Exchange (ETDEWEB)

    Suzuki, Kazuo [Tokyo Univ. (Japan). Faculty of Medicine

    1975-04-01

    Radioreceptor assay of insulin was discussed from the aspects of the measuring method, its merits and problems to be solved, and its clinical application. Rat liver 10 x g pellet was used as receptor site, and enzymatic degradation of insulin by the system contained in this fraction was inhibited by adding 1 mM p-CMB. /sup 125/I-labelled porcine insulin was made by lactoperoxidase method under overnight incubation at 4/sup 0/C and later purification by Sephadex G-25 column and Whatman CF-11 cellulose powder. Dog pancreatic vein serum insulin during and after the glucose load was determined by radioreceptor assay and radioimmunoassay resulting that both measurements accorded considerably. Radioreceptor assay would clarify the pathology of disorders of glucose metabolism including diabetes.

  14. Radioreceptor assay: theory and applications to pharmacology

    International Nuclear Information System (INIS)

    Perret, G.; Simon, P.

    1984-01-01

    The aim of the first part of this work is to present the theory of the radioreceptor assay and to compare it to the other techniques of radioanalysis (radioimmunoassay, competitive protein binding assays). The technology of the radioreceptor assay is then presented and its components (preparation of the receptors, radioligand, incubation medium) are described. The analytical characteristics of the radioreceptor assay (specificity, sensitivity, reproductibility, accuracy) and the pharmacological significance of the results are discussed. The second part is devoted to the description of the radioreceptor assays of some pharmacological classes (neuroleptics, tricyclic antidepressants, benzodiazepines, β-blockers, anticholinergic drugs) and to their use in therapeutic drug monitoring. In conclusion, by their nature, radioreceptor assays are highly sensitive, reliable, precise, accurate and simple to perform. Their chief disadvantage relates to specificity, since any substance having an appreciable affinity to the receptor site will displace the specifically bound radioligand. Paradoxically in some cases, this lack of specificity may be advantageous in that it allows for the detection of not only the apparent compound but of active metabolites and endogenous receptor agonists as well and in that radioreceptors assays can be devised for a whole pharmacological class and not only for one drug as it is the case for classical physico-chemical techniques. For all these reasons future of radioreceptor assay in pharmacology appears promising [fr

  15. Effect of borax on immune cell proliferation and sister chromatid exchange in human chromosomes

    OpenAIRE

    Pongsavee Malinee

    2009-01-01

    Abstract Background Borax is used as a food additive. It becomes toxic when accumulated in the body. It causes vomiting, fatigue and renal failure. Methods The heparinized blood samples from 40 healthy men were studied for the impact of borax toxicity on immune cell proliferation (lymphocyte proliferation) and sister chromatid exchange in human chromosomes. The MTT assay and Sister Chromatid Exchange (SCE) technic were used in this experiment with the borax concentrations of 0.1, 0.15, 0.2, 0...

  16. In Vitro Proliferation and Production of Cytokine and IgG by Human PBMCs Stimulated with Polysaccharide Extract from Plants Endemic to Gabon

    Directory of Open Access Journals (Sweden)

    Line Edwige Mengome

    2014-11-01

    Full Text Available Polysaccharides were extracted from seven plants endemic to Gabon to study their potential immunological activities. Peripheral blood mononuclear cell (PBMC (5 × 105 cells/mL proliferation, cytokine and immunoglobulin G (IgG assays were performed after stimulation with different concentrations of polysaccharide fractions compared with lipopolysaccharides (LPS and concanavalin A (ConA from healthy volunteers. The culture supernatants were used for cytokine and IgG detection by enzyme-linked immunosorbent assay (ELISA. The results show that pectin and hemicellulose extracts from Uvaria klainei, Petersianthus macrocarpus, Trichoscypha addonii, Aphanocalyx microphyllus, Librevillea klaineana, Neochevalierodendron stephanii and Scorodophloeus zenkeri induced production levels that were variable from one individual to another for IL-12 (3–40 pg/mL, IL-10 (6–443 pg/mL, IL-6 (7–370 pg/mL, GM-CSF (3–170 pg/mL and IFN-γ (5–80 pg/mL. Only hemicelluloses from Aphanocalyx microphyllus produce a small amount of IgG (OD = 0.034, while the proliferation of cells stimulated with these polysaccharides increased up to 318% above the proliferation of unstimulated cells. However, this proliferation of PBMCs was abolished when the pectin of some of these plants was treated with endopolygalacturonase (p < 0.05, but the trend of cytokine synthesis remained the same, both before and after enzymatic treatment or saponification. This study suggests that these polysaccharides stimulate cells in a structure-dependent manner. The rhamnogalacturonan-I (RGI fragment alone was not able to induce the proliferation of PBMC.

  17. Cell-patterned glass spray for direct drug assay using mass spectrometry

    International Nuclear Information System (INIS)

    Wu, Jing; Wang, Shiqi; Chen, Qiushui; Jiang, Hao; Liang, Shuping; Lin, Jin-Ming

    2015-01-01

    In this work, the establishment of a glass spray mass spectrometry (GS-MS) platform for direct cell-based drug assay was described. Cell co-culture, drug-induced cell apoptosis, proliferation analysis and intracellular drug absorption measurement were performed simultaneously on this specifically designed platform. Two groups of co-cultured cells (NIH-3T3/HepG2 and HepG2/MCF-7) were cultivated and they showed high viability within 3 days. The biocompatibility of the platform facilitated the subsequent bioassays, in which, cyclophosphamide (CPA) and genistein were used as the model drugs. The distinctions of cell apoptosis and proliferation between the mono-cultured and co-cultured cells were clearly observed and well explained by in situ GS-MS measurements. A satisfactory linearity of the calibration curve between the relative MS intensity and CPA concentrations was obtained using stable isotope labeling method (y = 0.16545 + 0.0985x, R"2 = 0.9937). The variations in the quantity of absorbed drug were detected and the results were consistent with the concentration-dependence of cell apoptosis. All the results demonstrated that direct cell-based drug assay could be performed on the stable isotope labeling assisted GS-MS platform in a facile and quantitative manner. - Highlights: • A versatile glass spray mass spectrometry (GS-MS) platform for direct cell-based drug assay was developed in this paper. • It has characteristics of the atmospheric pressure ionization method. • It is multifunctional for cell co-culture, bioassays, qualitative and quantitative intracellular drug absorption measurement. • GS-MS has the potential to increase the use of mass spectrometry in biological analysis.

  18. Scintillation proximity assay

    International Nuclear Information System (INIS)

    Hart, H.

    1980-01-01

    In a method of immunological assay two different classes of particles which interact at short distances to produce characteristic detectable signals are employed in a modification of the usual latex fixation test. In one embodiment an aqueous suspension of antigen coated tritiated latex particles (LH) and antigen coated polystyrene scintillant particles (L*) is employed to assay antibody in the aqueous medium. The amount of (LH) (L*) dimer formation and higher order aggregation induced and therefore the concentration of antibody (or antigen) present which caused the aggregation can be determined by using standard liquid scintillation counting equipment. (author)

  19. Assays for calcitonin receptors

    International Nuclear Information System (INIS)

    Teitelbaum, A.P.; Nissenson, R.A.; Arnaud, C.D.

    1985-01-01

    The assays for calcitonin receptors described focus on their use in the study of the well-established target organs for calcitonin, bone and kidney. The radioligand used in virtually all calcitonin binding studies is 125 I-labelled salmon calcitonin. The lack of methionine residues in this peptide permits the use of chloramine-T for the iodination reaction. Binding assays are described for intact bone, skeletal plasma membranes, renal plasma membranes, and primary kidney cell cultures of rats. Studies on calcitonin metabolism in laboratory animals and regulation of calcitonin receptors are reviewed

  20. A Comparison of Real-Time and Endpoint Cell Viability Assays for Improved Synthetic Lethal Drug Validation.

    Science.gov (United States)

    Single, Andrew; Beetham, Henry; Telford, Bryony J; Guilford, Parry; Chen, Augustine

    2015-12-01

    Cell viability assays fulfill a central role in drug discovery studies. It is therefore important to understand the advantages and disadvantages of the wide variety of available assay methodologies. In this study, we compared the performance of three endpoint assays (resazurin reduction, CellTiter-Glo, and nuclei enumeration) and two real-time systems (IncuCyte and xCELLigence). Of the endpoint approaches, both the resazurin reduction and CellTiter-Glo assays showed higher cell viabilities when compared directly to stained nuclei counts. The IncuCyte and xCELLigence real-time systems were comparable, and both were particularly effective at tracking the effects of drug treatment on cell proliferation at sub-confluent growth. However, the real-time systems failed to evaluate contrasting cell densities between drug-treated and control-treated cells at full growth confluency. Here, we showed that using real-time systems in combination with endpoint assays alleviates the disadvantages posed by each approach alone, providing a more effective means to evaluate drug toxicity in monolayer cell cultures. Such approaches were shown to be effective in elucidating the toxicity of synthetic lethal drugs in an isogenic pair of MCF10A breast cell lines. © 2015 Society for Laboratory Automation and Screening.

  1. Cell proliferation of Paramecium tetraurelia under simulated microgravity

    Science.gov (United States)

    Sawai, S.; Mogami, Y.; Baba, S. A.

    Paramecium is known to proliferate faster under microgravity in space and slower under hypergravity Experiments using axenic culture medium have demonstrated that the hypergravity affected directly on the proliferation of Paramecium itself Kato et al 2003 In order to assess the mechanisms underlying the physiological effects of gravity on cell proliferation Paramecium tetraurelia was grown under simulated microgravity performed by clinorotation and the time course of the proliferation was investigated in detail on the basis of the logistic analysis P tetraurelia was cultivated in a closed chamber in which cells were confined without air babbles reducing the shear stresses and turbulence under the rotation The chamber is made of quartz and silicone rubber film the former is for the optically-flat walls for the measurement of cell density by means of a non-invasive laser optical-slice method and the latter for gas exchange Because the closed chamber has an inner dimension of 3 times 3 times 60 mm Paramecium does not accumulate at the top of the chamber despite its negative gravitactic behavior We measured the cell density at regular time intervals without breaking the configuration of the chamber and analyzed the proliferation parameters by fitting the data to a logistic equation Clinorotation had the effects of reducing the proliferation of P tetraurelia It reduced both the saturation cell density and the maximum proliferation rate although it had little effect on the

  2. miR-494 represses HOXA10 expression and inhibits cell proliferation in oral cancer.

    Science.gov (United States)

    Libório-Kimura, Tatiana N; Jung, Hyun Min; Chan, Edward K L

    2015-02-01

    miR-494 was identified as a candidate of the most significantly underexpressed microRNAs (miRNAs) in our oral cancer screen. The aim of this study was to validate whether miR-494 has a functional role in oral cancer. Quantitative miRNA analyses were performed on oral tumor RNA and oral cancer cell lines. HOXA10 was selected for further analysis based on bioinformatics analysis of miR-494 targets and a previous report of overexpression of HOXA10 in oral cancer. Transient transfection of miRNA-mimic and inhibitor were performed in SCC-25 (tongue), CAL 27 (tongue), and FaDu (pharynx) cancer cells and regulation of HOXA10 by miR-494 was investigated. Dual luciferase assay was used to verify the interaction between miR-494 and HOXA10 in reporter cells. The effect of miR-494 on cell proliferation was examined. Our data showed that miR-494 was underexpressed whereas HOXA10 was overexpressed in oral cancer compared to normal tissues. An inverse correlation between miR-494 and HOXA10 was observed in the human tissues (pcancer cell lines significantly reduced the expression of HOXA10 mRNA. The luciferase reporter that contains the 3'UTR of HOXA10 showed a significantly reduced luciferase activity by miR-494 indicating a direct interaction between HOXA10 and miR-494. Significant reduction in cell proliferation was demonstrated in tongue cancer cells transfected with miR-494. miR-494 repressed the expression of HOXA10 and also reduced the proliferation of oral cancer cells. These data give more evidence of the role of miR-494 as a tumor suppressor miRNA in oral cancer. Copyright © 2014 Elsevier Ltd. All rights reserved.

  3. Nuclear proliferation and safeguards. Summary

    International Nuclear Information System (INIS)

    1982-03-01

    This comprehensive analysis of the technological, economic, and political factors affecting the potential spread of nuclear weapons proved useful in the congressional debate which culminated in the Nuclear Non-Proliferation Act of 1978. The report was subsequently published commercially and has been a frequently cited reference in the literature on proliferation and nuclear power. Despite developments since 1977, the information in the OTA report is still useful to those wishing to obtain an indepth understanding of the issues. Included is an analysis of why a nation might want nuclear weapons development program and the various sources of nuclear material are discussed. The control of proliferation is considered as well as its relation to the nuclear industry

  4. Domestic Politics and Nuclear Proliferation

    International Nuclear Information System (INIS)

    Kim, Chul Min; Yim, Man Sung

    2016-01-01

    The external security threat is known as the most important factor of nuclear weapons program, the domestic politics situation can also affect the nuclear proliferation decision of a country. For example, when a leader wants nuclear weapons as an ultimate weapon, the domestic politics situation can determine the effectiveness of the weapons program of a country. This study analyzes the current knowledge of the relationship between domestic politics and nuclear proliferation and suggests the main challenges of the quantitative models trying to calculate nuclear proliferation risk of countries. The domestic politics status is one of the most important indicators of nuclear program. However, some variables have never been used in quantitative analyses; for example, number of veto players and the public opinion on nuclear weapons; despite they are considered to be important in various qualitative studies. Future studies should focus on how should they be coded and how can they be linked with existing domestic politics variables

  5. Domestic Politics and Nuclear Proliferation

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Chul Min; Yim, Man Sung [KAIST, Daejeon (Korea, Republic of)

    2016-05-15

    The external security threat is known as the most important factor of nuclear weapons program, the domestic politics situation can also affect the nuclear proliferation decision of a country. For example, when a leader wants nuclear weapons as an ultimate weapon, the domestic politics situation can determine the effectiveness of the weapons program of a country. This study analyzes the current knowledge of the relationship between domestic politics and nuclear proliferation and suggests the main challenges of the quantitative models trying to calculate nuclear proliferation risk of countries. The domestic politics status is one of the most important indicators of nuclear program. However, some variables have never been used in quantitative analyses; for example, number of veto players and the public opinion on nuclear weapons; despite they are considered to be important in various qualitative studies. Future studies should focus on how should they be coded and how can they be linked with existing domestic politics variables.

  6. Nondestructive assay measurements applied to reprocessing plants

    International Nuclear Information System (INIS)

    Ruhter, Wayne D.; Lee, R. Stephen; Ottmar, Herbert; Guardini, Sergio

    1999-01-01

    Nondestructive assay for reprocessing plants relies on passive gamma-ray spectrometry for plutonium isotopic and plutonium mass values of medium-to-low-density samples and holdup deposits; on active x-ray fluorescence and densitometry techniques for uranium and plutonium concentrations in solutions; on calorimetry for plutonium mass in product; and passive neutron techniques for plutonium mass in spent fuel, product, and waste. This paper will describe the radiation-based nondestructive assay techniques used to perform materials accounting measurements. The paper will also discuss nondestructive assay measurements used in inspections of reprocessing plants [ru

  7. Ultracentrifuge and non-proliferation

    International Nuclear Information System (INIS)

    Voortman, A.J.

    1977-01-01

    The author states that there is no meaningful difference, from the point of view of proliferation between peaceful, civil, scientific application of nuclear fission, and the use of it in nuclear weapons. The proliferation of the nuclear technology for weapons appeared and appears to be closely connected with the spread of peaceful applications of nuclear technology. In connection with this, he discusses the Ultracentrifuge plant at Almelo (Netherlands) and the supply of nuclear technology by West-Germany especially to Brazil. Further the changed American policy and the possibility of an American/Russian deal to prevent the spread of the nuclear enrichment technology is discussed

  8. Lateral flow assays

    NARCIS (Netherlands)

    Posthuma-Trumpie, G.A.; Amerongen, van A.

    2012-01-01

    A simple version of immunochemical-based methods is the Lateral Flow Assay (LFA). It is a dry chemistry technique (reagents are included); the fluid from the sample runs through a porous membrane (often nitrocellulose) by capillary force. Typically the membrane is cut as a strip of 0.5*5 cm. In most

  9. Microchemiluminescent assay system

    Energy Technology Data Exchange (ETDEWEB)

    Kiel, J.L.

    1986-04-09

    The patent concerns a microchemiluminescent assay system, which can be used to detect ionizing radiation, heat or specific substances. The method involves the use of a complex formed from serum albumin and a luminescer which, in the presence of ionizing radiation (heat, or a specific analyte), will emit light in an amount proportional to the amount of radiation, etc. (U.K.).

  10. Hyaluronic Acid Assays

    DEFF Research Database (Denmark)

    Itenov, Theis S; Kirkby, Nikolai S; Bestle, Morten H

    2015-01-01

    BACKGROUD: Hyaluronic acid (HA) is proposed as a marker of functional liver capacity. The aim of the present study was to compare a new turbidimetric assay for measuring HA with the current standard method. METHODS: HA was measured by a particle-enhanced turbidimetric immunoassay (PETIA) and enzyme...

  11. Long non-coding RNA TUG1 promotes cell proliferation and metastasis by negatively regulating miR-300 in gallbladder carcinoma.

    Science.gov (United States)

    Ma, Fei; Wang, Shou-Hua; Cai, Qiang; Jin, Long-Yang; Zhou, Di; Ding, Jun; Quan, Zhi-Wei

    2017-04-01

    As we all know, long non-coding RNAs (lncRNAs) have been reported to play vital roles in various human cancers. In this study, we aimed to explore the role of lncRNA TUG1 in gallbladder carcinoma (GBC) development. Total RNA was extracted from the tissues of thirty GBC patients, four GBC cell lines. We detected the expression levels of TUG1 using quantitative real-time PCR. We performed CCK8, colony formation, transwell invasion and apoptosis assays to study the effects of TUG1 on GBC cell proliferation and invasion. Western blot assay was performed to assess to the expression level of epithelial-mesenchymal transition (EMT) markers in transforming growth factor-β1 (TGF-β1) treated and TUG1 knockdown GBC cell. Lastly, dual-luciferase reporter assay and quantitative real-time PCR were performed to verify the potential target microRNAs (miRNAs) of TUG1. TUG1 expression was significantly overexpressed in GBC tissues. Functionally, this study demonstrated that knockdown of TUG1 significantly inhibited GBC cell proliferation, metastasis. Mechanically, we found that TUG1 is upregulated by TGF-β1, and knockdown of TUG1 inhibited GBC cell EMT. Furthermore, we identified that miR-300, which has been reported as a suppressor in other types of cancer, is negatively regulated by TUG1. LncRNA TUG1 promotes GBC cell proliferation, metastasis and EMT progression by functioning as a miRNA sponge to abrogate the endogenous effect of miR-300. Copyright © 2017 Elsevier Masson SAS. All rights reserved.

  12. Effect of miR-146a-5p on proliferation and metastasis of triple-negative breast cancer via regulation of SOX5.

    Science.gov (United States)

    Si, Chengshuai; Yu, Qiao; Yao, Yufeng

    2018-05-01

    MicroRNA (miR)-146a-5p functions as a tumor suppressor in various types of cancer. However, the role of miR-146a-5p in the development of triple-negative breast cancer (TNBC) is unclear. The present study aimed to investigate the role of miR-146a-5p in TNBC. The expression level of miR-146a-5p in TNBC tissues and cell lines was initially detected using reverse transcription-quantitative polymerase chain reaction. To predict the target gene of miR-146a-5p, TargetScan software was used and a dual luciferase assay was performed to verify the prediction. Furthermore, in order to explore the role of miR-146a-5p in TNBC, miR-146a-5p was overexpressed in TNBC cells using miR-146a-5p mimics. An MTT assay was performed to detect cell proliferation, and a Transwell assay was conducted to determine cell migration and invasion. Furthermore, western blotting was performed to measure associated protein expression. It was revealed that miR-146a-5p was downregulated in TNBC tissues and cell lines. SOX5 was indicated to be a target gene of miR-146a-5p and was upregulated in TNBC cells. Additionally, miR-146a-5p could inhibit TNBC cell proliferation, migration and invasion, repress the expression of mesenchymal markers (N-cadherin, vimentin and fibronectin) and increase epithelial marker (E-cadherin) expression. Furthermore, SOX5 overexpression eliminated the effects of miR-146a-5p mimics on TNBC cells. In conclusion, the data of the present study indicated that miR-146a-5p inhibits the proliferation and metastasis of TNBC cells by regulating SOX5.

  13. Optical assay for biotechnology and clinical diagnosis.

    Science.gov (United States)

    Moczko, Ewa; Cauchi, Michael; Turner, Claire; Meglinski, Igor; Piletsky, Sergey

    2011-08-01

    In this paper, we present an optical diagnostic assay consisting of a mixture of environmental-sensitive fluorescent dyes combined with multivariate data analysis for quantitative and qualitative examination of biological and clinical samples. The performance of the assay is based on the analysis of spectrum of the selected fluorescent dyes with the operational principle similar to electronic nose and electronic tongue systems. This approach has been successfully applied for monitoring of growing cell cultures and identification of gastrointestinal diseases in humans.

  14. Calibration method for a radwaste assay system

    International Nuclear Information System (INIS)

    Dulama, C.; Dobrin, R.; Toma, Al.; Paunoiu, C.

    2004-01-01

    A waste assay system entirely designed and manufactured in the Institute for Nuclear Research is used in radwaste treatment and conditioning stream to ensure compliance with national repository radiological requirements. Usually, waste assay systems are calibrated by using various experimental arrangements including calibration phantoms. The paper presents a comparative study concerning the efficiency calibration performed by shell source method and a semiempirical, computational method based on a Monte Carlo algorithm. (authors)

  15. An European inter-laboratory validation of alternative endpoints of the murine local lymph node assay

    International Nuclear Information System (INIS)

    Ehling, G.; Hecht, M.; Heusener, A.; Huesler, J.; Gamer, A.O.; Loveren, H. van; Maurer, Th.; Riecke, K.; Ullmann, L.; Ulrich, P.; Vandebriel, R.; Vohr, H.-W.

    2005-01-01

    The original local lymph node assay (LLNA) is based on the use of radioactive labelling to measure cell proliferation. Other endpoints for the assessment of proliferation are also authorized by the OECD Guideline 429 provided there is appropriate scientific support, including full citations and description of the methodology (OECD, 2002. OECD Guideline for the Testing of Chemicals; Skin Sensitization: Local Lymph Node Assay, Guideline 429. Paris, adopted 24th April 2002.). Here, we describe the outcome of the second round of an inter-laboratory validation of alternative endpoints in the LLNA conducted in nine laboratories in Europe. The validation study was managed and supervised by the Swiss Agency for Therapeutic Products (Swissmedic) in Bern. Ear-draining lymph node (LN) weight and cell counts were used to assess LN cell proliferation instead of [3H]TdR incorporation. In addition, the acute inflammatory skin reaction was measured by ear weight determination of circular biopsies of the ears to identify skin irritation properties of the test items. The statistical analysis was performed in the department of statistics at the university of Bern. Similar to the EC 3 values defined for the radioactive method, threshold values were calculated for the endpoints measured in this modification of the LLNA. It was concluded that all parameters measured have to be taken into consideration for the categorisation of compounds due to their sensitising potencies. Therefore, an assessment scheme has been developed which turned out to be of great importance to consistently assess sensitisation versus irritancy based on the data of the different parameters. In contrast to the radioactive method, irritants have been picked up by all the laboratories applying this assessment scheme

  16. Cell proliferation of Paramecium tetraurelia on a slow rotating clinostat

    Science.gov (United States)

    Sawai, Satoe; Mogami, Yoshihiro; Baba, Shoji A.

    Paramecium is known to proliferate faster under microgravity conditions, and slower under hypergravity. Experiments using axenic culture medium have demonstrated that hypergravity affected directly on the proliferation of Paramecium itself. In order to assess the mechanisms underlying the physiological effects of gravity on cell proliferation, Paramecium tetraurelia was grown under clinorotation (2.5 rpm) and the time course of the proliferation was investigated in detail on the basis of the logistic analysis. On the basis of the mechanical properties of Paramecium, this slow rate of the rotation appears to be enough to simulate microgravity in terms of the randomization of the cell orientation with respect to gravity. P. tetraurelia was cultivated in a closed chamber in which cells were confined without air bubbles, reducing the shear forces and turbulences under clinorotation. The chamber is made of quartz and silicone rubber film; the former is for the optically-flat walls for the measurement of cell density by means of a non-invasive laser optical-slice method, and the latter for gas exchange. Because of the small dimension for culture space, Paramecium does not accumulate at the top of the chamber in spite of its known negative gravitactic behavior. We measured the cell density at regular time intervals without breaking the configuration of the chamber, and analyzed the proliferation parameters by fitting the data to a logistic equation. As a result, P. tetraurelia showed reduced proliferation under slow clinorotation. The saturation of the cell density as well as the maximum proliferation rate decreased, although we found no significant changes on the half maximal time for proliferation. We also found that the mean swimming velocity decreased under slow clinorotation. These results were not consistent with those under microgravity and fast rotating clinostat. This may suggest that randomization of the cell orientation performed by slow rotating clinostat has

  17. Biomonitoring of genotoxic risk in radar facility workers: comparison of the comet assay with micronucleus assay and chromatid breakage assay

    International Nuclear Information System (INIS)

    Garaj-Vrhovac, V.; Kopjar, N.

    2003-01-01

    Genotoxic risks of occupational exposure in a radar facility were evaluated by using alkaline comet assay, micronucleus assay and chromatid breakage assay on peripheral blood leukocytes in exposed subjects and corresponding controls. Results show that occupational exposure to microwave radiation correlates with an increase of genome damage in somatic cells. The levels of DNA damage in exposed subjects determined by using alkaline comet assay were increased compared to control and showed interindividual variations. Incidence of micronuclei was also significantly increased compared to baseline control values. After short exposure of cultured lymphocytes to bleomycin, cells of occupationally exposed subjects responded with high numbers of chromatid breaks. Although the level of chromosome damage generated by bleomycin varied greatly between individuals, in exposed subjects a significantly elevated number of chromatid breaks was observed. Our results support data reported in literature indicating that microwave radiation represents a potential DNA-damaging hazard. Alkaline comet assay is confirmed as a sensitive and highly reproducible technique for detection of primary DNA damage inflicted in somatic cells. Micronucleus assay was confirmed as reliable bio-markers of effect and chromatid breakage assay as sensitive bio-marker of individual cancer susceptibility. The results obtained also confirm the necessity to improve measures and to perform accurate health surveillance of individuals occupationally exposed to microwave radiation

  18. Heme-induced Trypanosoma cruzi proliferation is mediated by CaM kinase II

    International Nuclear Information System (INIS)

    Souza, C.F.; Carneiro, A.B.; Silveira, A.B.; Laranja, G.A.T.; Silva-Neto, M.A.C.; Costa, S.C. Goncalves da; Paes, M.C.

    2009-01-01

    Trypanosoma cruzi, the etiologic agent of Chagas disease, is transmitted through triatomine vectors during their blood-meal on vertebrate hosts. These hematophagous insects usually ingest approximately 10 mM of heme bound to hemoglobin in a single meal. Blood forms of the parasite are transformed into epimastigotes in the crop which initiates a few hours after parasite ingestion. In a previous work, we investigated the role of heme in parasite cell proliferation and showed that the addition of heme significantly increased parasite proliferation in a dose-dependent manner . To investigate whether the heme effect is mediated by protein kinase signalling pathways, parasite proliferation was evaluated in the presence of several protein kinase (PK) inhibitors. We found that only KN-93, a classical inhibitor of calcium-calmodulin-dependent kinases (CaMKs), blocked heme-induced cell proliferation. KN-92, an inactive analogue of KN-93, was not able to block this effect. A T. cruzi CaMKII homologue is most likely the main enzyme invo