WorldWideScience

Sample records for projection tomography opt

  1. OPTiM: Optical projection tomography integrated microscope using open-source hardware and software.

    Science.gov (United States)

    Watson, Thomas; Andrews, Natalie; Davis, Samuel; Bugeon, Laurence; Dallman, Margaret D; McGinty, James

    2017-01-01

    We describe the implementation of an OPT plate to perform optical projection tomography (OPT) on a commercial wide-field inverted microscope, using our open-source hardware and software. The OPT plate includes a tilt adjustment for alignment and a stepper motor for sample rotation as required by standard projection tomography. Depending on magnification requirements, three methods of performing OPT are detailed using this adaptor plate: a conventional direct OPT method requiring only the addition of a limiting aperture behind the objective lens; an external optical-relay method allowing conventional OPT to be performed at magnifications >4x; a remote focal scanning and region-of-interest method for improved spatial resolution OPT (up to ~1.6 μm). All three methods use the microscope's existing incoherent light source (i.e. arc-lamp) and all of its inherent functionality is maintained for day-to-day use. OPT acquisitions are performed on in vivo zebrafish embryos to demonstrate the implementations' viability.

  2. 75 FR 11169 - Reedsport OPT Wave Park Project; Reedsport OPT Wave Park; LLC Notice of Scoping Meetings and...

    Science.gov (United States)

    2010-03-10

    ... DEPARTMENT OF ENERGY Federal Energy Regulatory Commission [Project No. 12713-002] Reedsport OPT Wave Park Project; Reedsport OPT Wave Park; LLC Notice of Scoping Meetings and Environmental Site...: Reedsport OPT Wave Park, LLC. e. Name of Project: Reedsport OPT Wave Park Project. [[Page 11170

  3. 3D visualization of the initial Yersinia ruckeri infection route in rainbow trout (Oncorhynchus mykiss) by optical projection tomography

    DEFF Research Database (Denmark)

    Otani, Maki; Villumsen, Kasper Rømer; Kragelund Strøm, Helene

    2014-01-01

    , optical projection tomography (OPT), a novel three-dimensional (3D) bio-imaging technique, was applied. OPT not only enables the visualization of Y. ruckeri on mucosal surfaces but also the 3D spatial distribution in whole organs, without sectioning. Rainbow trout were infected by bath challenge exposure...

  4. Accelerated Optical Projection Tomography Applied to In Vivo Imaging of Zebrafish.

    Directory of Open Access Journals (Sweden)

    Teresa Correia

    Full Text Available Optical projection tomography (OPT provides a non-invasive 3-D imaging modality that can be applied to longitudinal studies of live disease models, including in zebrafish. Current limitations include the requirement of a minimum number of angular projections for reconstruction of reasonable OPT images using filtered back projection (FBP, which is typically several hundred, leading to acquisition times of several minutes. It is highly desirable to decrease the number of required angular projections to decrease both the total acquisition time and the light dose to the sample. This is particularly important to enable longitudinal studies, which involve measurements of the same fish at different time points. In this work, we demonstrate that the use of an iterative algorithm to reconstruct sparsely sampled OPT data sets can provide useful 3-D images with 50 or fewer projections, thereby significantly decreasing the minimum acquisition time and light dose while maintaining image quality. A transgenic zebrafish embryo with fluorescent labelling of the vasculature was imaged to acquire densely sampled (800 projections and under-sampled data sets of transmitted and fluorescence projection images. The under-sampled OPT data sets were reconstructed using an iterative total variation-based image reconstruction algorithm and compared against FBP reconstructions of the densely sampled data sets. To illustrate the potential for quantitative analysis following rapid OPT data acquisition, a Hessian-based method was applied to automatically segment the reconstructed images to select the vasculature network. Results showed that 3-D images of the zebrafish embryo and its vasculature of sufficient visual quality for quantitative analysis can be reconstructed using the iterative algorithm from only 32 projections-achieving up to 28 times improvement in imaging speed and leading to total acquisition times of a few seconds.

  5. Special section: OptIPlanet - The OptIPuter global collaboratory

    NARCIS (Netherlands)

    Smarr, L.; Brown, M.; de Laat, C.

    The technological developments made by OptIPuter research project as an OptIPlanet Collaboratory of virtual organizations, in various scientific and technology domains, enhancing and contributing to this evolving cyberinfrastructure to solve complex global problems, are summarized. OptIPuter project

  6. Macro optical projection tomography for large scale 3D imaging of plant structures and gene activity.

    Science.gov (United States)

    Lee, Karen J I; Calder, Grant M; Hindle, Christopher R; Newman, Jacob L; Robinson, Simon N; Avondo, Jerome J H Y; Coen, Enrico S

    2017-01-01

    Optical projection tomography (OPT) is a well-established method for visualising gene activity in plants and animals. However, a limitation of conventional OPT is that the specimen upper size limit precludes its application to larger structures. To address this problem we constructed a macro version called Macro OPT (M-OPT). We apply M-OPT to 3D live imaging of gene activity in growing whole plants and to visualise structural morphology in large optically cleared plant and insect specimens up to 60 mm tall and 45 mm deep. We also show how M-OPT can be used to image gene expression domains in 3D within fixed tissue and to visualise gene activity in 3D in clones of growing young whole Arabidopsis plants. A further application of M-OPT is to visualise plant-insect interactions. Thus M-OPT provides an effective 3D imaging platform that allows the study of gene activity, internal plant structures and plant-insect interactions at a macroscopic scale. © The Author 2016. Published by Oxford University Press on behalf of the Society for Experimental Biology.

  7. An evaluation of meniscal collagenous structure using optical projection tomography

    International Nuclear Information System (INIS)

    Andrews, Stephen HJ; Ronsky, Janet L; Rattner, Jerome B; Shrive, Nigel G; Jamniczky, Heather A

    2013-01-01

    The collagenous structure of menisci is a complex network of circumferentially oriented fascicles and interwoven radially oriented tie-fibres. To date, examination of this micro- architecture has been limited to two-dimensional imaging techniques. The purpose of this study was to evaluate the ability of the three-dimensional imaging technique; optical projection tomography (OPT), to visualize the collagenous structure of the meniscus. If successful, this technique would be the first to visualize the macroscopic orientation of collagen fascicles in 3-D in the meniscus and could further refine load bearing mechanisms in the tissue. OPT is an imaging technique capable of imaging samples on the meso-scale (1-10 mm) at a micro-scale resolution. The technique, similar to computed tomography, takes two-dimensional images of objects from incremental angles around the object and reconstructs them using a back projection algorithm to determine three-dimensional structure. Bovine meniscal samples were imaged from four locations (outer main body, femoral surface, tibial surface and inner main body) to determine the variation in collagen orientation throughout the tissue. Bovine stifles (n = 2) were obtained from a local abattoir and the menisci carefully dissected. Menisci were fixed in methanol and subsequently cut using a custom cutting jig (n = 4 samples per meniscus). Samples were then mounted in agarose, dehydrated in methanol and subsequently cleared using benzyl alcohol benzyl benzoate (BABB) and imaged using OPT. Results indicate circumferential, radial and oblique collagenous orientations at the contact surfaces and in the inner third of the main body of the meniscus. Imaging identified fascicles ranging from 80-420 μm in diameter. Transition zones where fascicles were found to have a woven or braided appearance were also identified. The outer-third of the main body was composed of fascicles oriented predominantly in the circumferential direction. Blood vessels were

  8. Block matching 3D random noise filtering for absorption optical projection tomography

    International Nuclear Information System (INIS)

    Fumene Feruglio, P; Vinegoni, C; Weissleder, R; Gros, J; Sbarbati, A

    2010-01-01

    Absorption and emission optical projection tomography (OPT), alternatively referred to as optical computed tomography (optical-CT) and optical-emission computed tomography (optical-ECT), are recently developed three-dimensional imaging techniques with value for developmental biology and ex vivo gene expression studies. The techniques' principles are similar to the ones used for x-ray computed tomography and are based on the approximation of negligible light scattering in optically cleared samples. The optical clearing is achieved by a chemical procedure which aims at substituting the cellular fluids within the sample with a cell membranes' index matching solution. Once cleared the sample presents very low scattering and is then illuminated with a light collimated beam whose intensity is captured in transillumination mode by a CCD camera. Different projection images of the sample are subsequently obtained over a 360 0 full rotation, and a standard backprojection algorithm can be used in a similar fashion as for x-ray tomography in order to obtain absorption maps. Because not all biological samples present significant absorption contrast, it is not always possible to obtain projections with a good signal-to-noise ratio, a condition necessary to achieve high-quality tomographic reconstructions. Such is the case for example, for early stage's embryos. In this work we demonstrate how, through the use of a random noise removal algorithm, the image quality of the reconstructions can be considerably improved even when the noise is strongly present in the acquired projections. Specifically, we implemented a block matching 3D (BM3D) filter applying it separately on each acquired transillumination projection before performing a complete three-dimensional tomographical reconstruction. To test the efficiency of the adopted filtering scheme, a phantom and a real biological sample were processed. In both cases, the BM3D filter led to a signal-to-noise ratio increment of over 30 d

  9. Three-dimensional imaging analysis of Yersinia ruckeri infected rainbow trout (Oncorhynchus mykiss) gills by optical projection tomography

    DEFF Research Database (Denmark)

    Otani, Maki; Raida, Martin Kristian

    Optical projection tomography (OPT) is a new tool for three-dimensional (3D) imaging of small tissues or embryos, based on multi-angle recording of internal fluorescent signals using intact whole mount tissue or fish. To understand the route of infection, gills of Y. ruckeri infected rainbow trout...... were labeled with fluorescent antibody and visualized in 3D by the OPT scanner. Rainbow trout were infected with Y. ruckeri O1 biotype 1 (1 x 109 cells/ml) for 1 hour at 18 °C, and then transferred to clean water. Three fish were sampled at 12 different time points and fixed in 4% PFA. The gills were...... incubated whole with rabbit anti-Y. ruckeri polyclonal antibody and Alexa Fluor®594 conjugated goat anti-rabbit IgG. After embedding in 1% low melting point agarose, specimens were dehydrated in 100% methanol and cleared in BABB (benzyl alcohol: benzyl benzoate) for OPT scanning. 3D imaging results showed...

  10. Who opts out of a project for health promotion with incentives?: Empirical research on the effect of rewards to motivate persistence.

    Science.gov (United States)

    Okamoto, Shohei; Komamura, Kohei; Tanabe, Kai; Yokoyama, Noriko; Tsukao, Akiko; Chijiki, Shoko; Kuno, Shinya

    2017-01-01

    Objectives Although providing incentives for a better lifestyle has been of increasing concern, there is insufficient evidence about its effect. Therefore, this research aims to discover new insights by verifying the effect of rewards to motivate persistence in a project for health promotion.Methods A total of 7,622 participants of an incentivized project for health promotion (Wellness Point Project) were recruited from 6 municipalities in Japan, namely Tohoku, Chubu, Kanto, Kinki, and Chugoku, of which the 4,291 individuals who had the necessary information for estimation were analyzed. Persistence in the project was judged by whether there was information about daily steps and/or participation in some fitness classes every month for one year at most. In addition, we used the reason participants chose certain rewards in order to categorize the characteristic of rewards, and estimated opt-out hazard ratios from the project using survival time analysis. Furthermore, the estimation in the model included individual features such as age, education, status of physical activity before joining the project, lifestyles such as smoking, drinking, and so on.Results A multivariate analysis reveals that those who had chosen a reward for regional contribution were more likely to opt out than those who had chosen a certain reward because it is close to cash. The opt-out hazard ratio was 1.63 (95% CI: 1.18-2.25) among men and 1.40 (95% CI: 1.08-1.81) among women. In addition, insufficient physical activity, smoking, working for men, and physical condition for women were associated with opt-out.Conclusions This research verified that a reward that participants felt was close to cash, compared to the internal motivation of regional contribution, could enhance the persistence rate of the project. Moreover, it was found that not only giving incentives but also considering participants' conditions is necessary to enhance persistence.

  11. 3 dimensional modelling of early human brain development using optical projection tomography

    Directory of Open Access Journals (Sweden)

    Strachan Tom

    2004-08-01

    Full Text Available Abstract Background As development proceeds the human embryo attains an ever more complex three dimensional (3D structure. Analyzing the gene expression patterns that underlie these changes and interpreting their significance depends on identifying the anatomical structures to which they map and following these patterns in developing 3D structures over time. The difficulty of this task greatly increases as more gene expression patterns are added, particularly in organs with complex 3D structures such as the brain. Optical Projection Tomography (OPT is a new technology which has been developed for rapidly generating digital 3D models of intact specimens. We have assessed the resolution of unstained neuronal structures within a Carnegie Stage (CS17 OPT model and tested its use as a framework onto which anatomical structures can be defined and gene expression data mapped. Results Resolution of the OPT models was assessed by comparison of digital sections with physical sections stained, either with haematoxylin and eosin (H&E or by immunocytochemistry for GAP43 or PAX6, to identify specific anatomical features. Despite the 3D models being of unstained tissue, peripheral nervous system structures from the trigeminal ganglion (~300 μm by ~150 μm to the rootlets of cranial nerve XII (~20 μm in diameter were clearly identifiable, as were structures in the developing neural tube such as the zona limitans intrathalamica (core is ~30 μm thick. Fourteen anatomical domains have been identified and visualised within the CS17 model. Two 3D gene expression domains, known to be defined by Pax6 expression in the mouse, were clearly visible when PAX6 data from 2D sections were mapped to the CS17 model. The feasibility of applying the OPT technology to all stages from CS12 to CS23, which encompasses the major period of organogenesis for the human developing central nervous system, was successfully demonstrated. Conclusion In the CS17 model considerable detail

  12. Inclusion of residual tissue in biobanks: opt-in or opt-out?

    Directory of Open Access Journals (Sweden)

    Noor A A Giesbertz

    Full Text Available Residual samples are an important source of tissue for biobanks. They refer to leftover tissue that is obtained in the course of clinical care. Residual samples can be included through an opt-in method--that is, a person explicitly expresses consent to include residual tissue--or an opt-out method--that is, the tissue is stored unless a person explicitly refuses. At the moment there is a renewed interest in the appropriate method for the inclusion of residual samples in biobanks. The expansion of biobanks and rapid developments in biomedical research underscore the need to evaluate the proper procedure. In this article we revisit the arguments in favor and against opt-in and opt-out methods for residual tissue research. We conclude firstly that an opt-out method is only justifiable when certain conditions are met: (1 awareness has to be raised, (2 sufficient information has to be provided, and (3 a genuine possibility to object has to be offered. An opt-out procedure that fulfills these conditions can be called a "thick" opt-out method. As a consequence, the dichotomy between opt-in and opt-out is less stark than usually suggested, as both methods require a certain amount of effort. Secondly, we conclude that because of the diversity of tissue and research, not every situation can be treated alike. There are at least four situations that require opt-in procedures: (1 research with higher risks or increased burdens, (2 the use of controversial or high-impact techniques, (3 research on sensitive tissue types, and (4 research involving vulnerable patients. We suggest that further interdisciplinary debate should answer the question when to opt-in or when to opt-out.

  13. No opt-out is forever. Sweden opts back in

    International Nuclear Information System (INIS)

    Schneider, Horst

    2010-01-01

    The draft legislation by the conservative-liberal Swedish government of early 2010, which was adopted by the Swedish parliament on June 17, 2010, not only repeals the shutdown of all Swedish nuclear power plants, which had earlier been foreseen by this year, but permits the construction and operation of new plants. In Sweden, a referendum in 1980 started the opt-out process. Shutdown within 30 years was foreseen in the regulation. As early as in late 1995, an Energy Committee appointed by the government reported that a complete opt-out by 2010 was impossible to achieve on economic and environmental grounds. Under the 1997 Opt-out Act, the government may shut down nuclear power plants at any time against an indemnification - unlike Germany. Another prerequisite is the realistic availability of new energy sources. As a consequence, only 2 nuclear power plants have been shut down so far, mainly because of protests from neighboring Denmark. Thirty years after the referendum, the acceptance of nuclear power in Sweden is high and stable. In line with growing public acceptance in the course of the debate about climate change, the Christian-Democratic Party changed its policy in March 2007, opting out of the opt-out. Finally, the conservative-liberal Swedish government submitted draft legislation to parliament which also permitted building new nuclear power plants. The Social Democratic Workers' Party, which is in the opposition, stuck to its rejection of the use of nuclear power and announced its intention to reverse the repeal of the opt-out in September 2010, after parliamentary elections and a possible new red-green government. The public and political developments in Sweden show that social attitudes towards nuclear power, opt-out policies and legal regulations can change. Adopting a rational attitude when discussing nuclear power and realities is possible, and political views sooner or later will adapt to the new situation. This could happen also in Germany

  14. Default options and social welfare : Opt in versus opt out

    NARCIS (Netherlands)

    Bouckaert, J.M.C.; Degryse, H.A.

    2013-01-01

    We offer a social-welfare comparison of the two most prominent default options – opt in and opt out – using a two-period model of localized competition. We demonstrate that when consumers stick to the default option, the prevailing default policy shapes firms' ability to collect and use customer

  15. 17 CFR 248.7 - Form of opt out notice to consumers; opt out methods.

    Science.gov (United States)

    2010-04-01

    ... the right to disclose nonpublic personal information about your consumer to a nonaffiliated third party; (ii) That the consumer has the right to opt out of that disclosure; and (iii) A reasonable means by which the consumer may exercise the opt out right. (2) Examples—(i) Adequate opt out notice. You...

  16. 12 CFR 573.7 - Form of opt out notice to consumers; opt out methods.

    Science.gov (United States)

    2010-01-01

    ... reserve the right to disclose nonpublic personal information about your consumer to a nonaffiliated third party; (ii) That the consumer has the right to opt out of that disclosure; and (iii) A reasonable means by which the consumer may exercise the opt out right. (2) Examples—(i) Adequate opt out notice. You...

  17. 12 CFR 40.7 - Form of opt out notice to consumers; opt out methods.

    Science.gov (United States)

    2010-01-01

    ... discloses or reserves the right to disclose nonpublic personal information about its consumer to a nonaffiliated third party; (ii) That the consumer has the right to opt out of that disclosure; and (iii) A reasonable means by which the consumer may exercise the opt out right. (2) Examples. (i) Adequate opt out...

  18. 16 CFR 313.7 - Form of opt out notice to consumers; opt out methods.

    Science.gov (United States)

    2010-01-01

    ... your consumers that accurately explains the right to opt out under that section. The notice must state... consumer to a nonaffiliated third party; (ii) That the consumer has the right to opt out of that disclosure; and (iii) A reasonable means by which the consumer may exercise the opt out right. (2) Examples—(i...

  19. 12 CFR 332.7 - Form of opt out notice to consumers; opt out methods.

    Science.gov (United States)

    2010-01-01

    ... each of your consumers that accurately explains the right to opt out under that section. The notice... your consumer to a nonaffiliated third party; (ii) That the consumer has the right to opt out of that disclosure; and (iii) A reasonable means by which the consumer may exercise the opt out right. (2) Examples...

  20. 12 CFR 216.7 - Form of opt out notice to consumers; opt out methods.

    Science.gov (United States)

    2010-01-01

    ... each of your consumers that accurately explains the right to opt out under that section. The notice... your consumer to a nonaffiliated third party; (ii) That the consumer has the right to opt out of that disclosure; and (iii) A reasonable means by which the consumer may exercise the opt out right. (2) Examples...

  1. Spherical projections and liftings in geometric tomography

    DEFF Research Database (Denmark)

    Goodey, Paul; Kiderlen, Markus; Weil, Wolfgang

    2011-01-01

    We consider a variety of integral transforms arising in Geometric Tomography. It will be shown that these can be put into a common framework using spherical projection and lifting operators. These operators will be applied to support functions and surface area measures of convex bodies and to rad......We consider a variety of integral transforms arising in Geometric Tomography. It will be shown that these can be put into a common framework using spherical projection and lifting operators. These operators will be applied to support functions and surface area measures of convex bodies...... and to radial functions of star bodies. We then investigate averages of lifted projections and show that they correspond to self-adjoint intertwining operators. We obtain formulas for the eigenvalues of these operators and use them to ascertain circumstances under which tomographic measurements determine...... the original bodies. This approach via mean lifted projections leads us to some unexpected relationships between seemingly disparate geometric constructions....

  2. 12 CFR 716.7 - Form of opt out notice to consumers and opt out methods.

    Science.gov (United States)

    2010-01-01

    ... your consumers that accurately explains the right to opt out under that section. The notice must state... consumer to a nonaffiliated third party; (ii) That the consumer has the right to opt out of that disclosure; and (iii) A reasonable means by which the consumer may exercise the opt out right. (2) Examples. (i...

  3. SDART: An algorithm for discrete tomography from noisy projections

    NARCIS (Netherlands)

    F. Bleichrodt (Folkert); F. Tabak (Frank); K.J. Batenburg (Joost)

    2014-01-01

    htmlabstractComputed tomography is a noninvasive technique for reconstructing an object from projection data. If the object consists of only a few materials, discrete tomography allows us to use prior knowledge of the gray values corresponding to these materials to improve the accuracy of the

  4. The rise and fall of an opt-out system.

    Science.gov (United States)

    Nordfalk, Francisca; Hoeyer, Klaus

    2018-04-01

    In Denmark, citizens participate in register-based research without the possibility of opting out. However, in 1995 it was made possible for Danish citizens to register an opt-out called 'researcher protection' [ forskerbeskyttelse], which implied that researchers could not contact people to invite them to participate in research projects, such as clinical trials or questionnaries, based on their registrations in national registers. Data already registered could still be used for research. In 2014, this possibility of opt-out was revoked by law. The aims of this paper are to understand how the Danish researcher protection system came about, why it was terminated and what we can we learn from this example. We conducted a descriptive analysis of a copy of the former researcher protection register along with policies and media debate surrounding the rise and revocation of the researcher protection system. Our results show how both the inception and the abolishment of researcher protection appear to be ad hoc and without specified criteria of success. An examination of the recorded entries in the researcher protection registry could have led to changes in its administration as an alternative to its total abolition. In future opt-out systems, there should be focus on monitoring register practices and the purpose and criteria for evaluation must be defined prior to implementation.

  5. Opting Out of the European Union

    DEFF Research Database (Denmark)

    Adler-Nissen, Rebecca

    controversial cases of differentiated integration: the British and Danish opt-outs from Economic and Monetary Union and European policies on borders, asylum, migration, internal security and justice. Drawing on over one hundred interviews with national representatives and EU officials, the author demonstrates......European integration continues to deepen despite major crises and attempts to take back sovereignty. A growing number of member states are reacting to a more constraining EU by negotiating opt-outs. This book provides the first in-depth account of how opt-outs work in practice. It examines the most...... how representatives manage the stigma of opting out, allowing them to influence even politically sensitive areas covered by their opt-outs. Developing a practice approach to European integration, the book shows how everyday negotiations transform national interests into European ideals. It is usually...

  6. No opt-out is forever. Sweden opts back in; Ausstieg ist nie endgueltig. Schweden kehrt um

    Energy Technology Data Exchange (ETDEWEB)

    Schneider, Horst

    2010-06-15

    The draft legislation by the conservative-liberal Swedish government of early 2010, which was adopted by the Swedish parliament on June 17, 2010, not only repeals the shutdown of all Swedish nuclear power plants, which had earlier been foreseen by this year, but permits the construction and operation of new plants. In Sweden, a referendum in 1980 started the opt-out process. Shutdown within 30 years was foreseen in the regulation. As early as in late 1995, an Energy Committee appointed by the government reported that a complete opt-out by 2010 was impossible to achieve on economic and environmental grounds. Under the 1997 Opt-out Act, the government may shut down nuclear power plants at any time against an indemnification - unlike Germany. Another prerequisite is the realistic availability of new energy sources. As a consequence, only 2 nuclear power plants have been shut down so far, mainly because of protests from neighboring Denmark. Thirty years after the referendum, the acceptance of nuclear power in Sweden is high and stable. In line with growing public acceptance in the course of the debate about climate change, the Christian-Democratic Party changed its policy in March 2007, opting out of the opt-out. Finally, the conservative-liberal Swedish government submitted draft legislation to parliament which also permitted building new nuclear power plants. The Social Democratic Workers' Party, which is in the opposition, stuck to its rejection of the use of nuclear power and announced its intention to reverse the repeal of the opt-out in September 2010, after parliamentary elections and a possible new red-green government. The public and political developments in Sweden show that social attitudes towards nuclear power, opt-out policies and legal regulations can change. Adopting a rational attitude when discussing nuclear power and realities is possible, and political views sooner or later will adapt to the new situation. This could happen also in Germany

  7. Sacrificio cortoplacista adaptativo 2opt (SCA_2opt: Una heurística inspirada en el pensamiento sistémico Sacrifice short-term adaptive 2-opt (SCA_2opt: A heuristic inspired by systems thinking

    Directory of Open Access Journals (Sweden)

    Jorge Pérez Rave

    2013-01-01

    Full Text Available Se detalla el origen de dos noveles heurísticas para el TSP simétrico, inspiradas en el pensamiento sistémico: Sacrificio Cortoplacista Adaptativo 2-opt (SCA_2opt y SCA_2_opt_r. Estas surgen del análisis sistémico de la regla de decisión Vecino más cercano, identificándosele el arquetipo "Soluciones contraproducentes". El SCA se basa en que el agente viajero renuncie en un momento dado a una ciudad inmediatamente cercana, y se traslade hacia la segunda ciudad más cercana disponible. A partir de ello, se continúa con la regla del vecino más cercano. Cada que se realiza el SCA (búsqueda global se efectúa una búsqueda local 2_opt. Considerando el binomio eficacia y eficiencia, las dos heurísticas se muestran prometedoras en comparación multicriterio contra 19 metaheurísticas. Se evidencia que el pensamiento sistémico es un campo de inspiración viable para el desarrollo de métodos de optimización combinatoria; se plasman preguntas emergentes para desarrollos futuros, que permitan continuar integrando elementos de la optimización clásica con el pensamiento sistémico; áreas tradicionalmente vistas como antagónicas, pero cuyo diálogo se muestra favorable en este artículo.Outlining two novice heuristics for the symmetric TSP, inspired systemic thinking: Sacrifice short-term adaptive 2-opt (SCA2opt and SCA_2opt_r. These arise from the systemic analysis of the rule of decision, nearest neighbour, identifying the archetype "Counterproductive solutions". SCA relies on that agent traveler, renounces at any given time immediately to a nearby city, and moves towards the second nearest available city. From there, it continues with the nearest neighbour rule. Each is the SCA (global search operates a local search 2opt. Where as the binomial effectiveness and efficiency, the two new heuristics are shown promising in comparison multicriteria against 19 metaheuristics. It is evident that systemic thinking is a field of inspiration viable

  8. Opting in and opting out: a grounded theory of nursing's contribution to inpatient rehabilitation.

    Science.gov (United States)

    Pryor, Julie; Walker, Annette; O'Connell, Beverly; Worrall-Carter, Linda

    2009-12-01

    To develop a grounded theory of nursing's contribution to patient rehabilitation from the perspective of nurses working in inpatient rehabilitation. Grounded theory method, informed by the theoretical perspective of symbolic interactionism, was used to guide data collection and analysis, and the development of a grounded theory. Five inpatient rehabilitation units in Australia. Thirty-five registered and 18 enrolled nurses participated in audio-taped interviews and/or were observed during periods of their everyday practice. The analysis revealed a situation whereby nurses made decisions about when to 'opt in' and when to 'opt out' of inpatient rehabilitation. This occurred on two levels: with their interaction with patients and allied health professionals, and when faced with negative system issues that impacted on their ability to contribute to patient rehabilitation. The primary contribution nurses made to inpatient rehabilitation was working directly with patients, enabling them to self-care. Nurses coached patients when their decisions about 'opting in' and 'opting out' were based on assessment of the person in their particular context. In contrast, the nurses mostly distanced themselves from system-based problems, 'opting out' of addressing them. They did this not to make their working lives easier, but more manageable. System-based problems impacted negatively on the nurses' ability to deliver comprehensive rehabilitation care. As a consequence, some nurses felt unable to influence the care and they withdrew professionally to make their work lives more manageable.

  9. Calient Networks chosen as core platform for OptIPuter

    CERN Multimedia

    2003-01-01

    Calient Networks, a provider of intelligent all-optical switching systems and software, will team with the California Institute for Telecommunications and Information Technology (Cal-(IT)2) and the University of Illinois at Chicago (UIC) on development of the "OptIPuter,". This is a powerful distributed cyber-infrastructure project designed to support data-intensive scientific research and collaboration (1/2 page).

  10. Image reconstruction technique using projection data from neutron tomography system

    Directory of Open Access Journals (Sweden)

    Waleed Abd el Bar

    2015-12-01

    Full Text Available Neutron tomography is a very powerful technique for nondestructive evaluation of heavy industrial components as well as for soft hydrogenous materials enclosed in heavy metals which are usually difficult to image using X-rays. Due to the properties of the image acquisition system, the projection images are distorted by several artifacts, and these reduce the quality of the reconstruction. In order to eliminate these harmful effects the projection images should be corrected before reconstruction. This paper gives a description of a filter back projection (FBP technique, which is used for reconstruction of projected data obtained from transmission measurements by neutron tomography system We demonstrated the use of spatial Discrete Fourier Transform (DFT and the 2D Inverse DFT in the formulation of the method, and outlined the theory of reconstruction of a 2D neutron image from a sequence of 1D projections taken at different angles between 0 and π in MATLAB environment. Projections are generated by applying the Radon transform to the original image at different angles.

  11. Projection radiography and tomography

    International Nuclear Information System (INIS)

    Tobias, C.A.; Fabrikant, J.I.; Benton, E.V.; Holley, W.R.

    1980-01-01

    Our program on heavy-ion radiography began soon after heavy ions were accelerated to high energies. Heavy ions are capable of very high electron density discrimination combined with good radial image resolution and low dose. Since heavy-ion beams produce many secondries, plastic nuclear detectors have an advantage for recording heavy-ion images. Projection imaging is now a practical technique that can resolve density differences between normal tissue and tumor tissue in some cases in which X rays could not make a distinction. Initial attempts at heavy-ion tomography also indicate potential for high resolution in this field. The physical basis for heavy-ion radiography and tomographic reconstruction studies are discussed in detail

  12. Ultrasonic computerized tomography (CT) for temperature measurements with limited projection data based on extrapolated filtered back projection (FBP) method

    International Nuclear Information System (INIS)

    Zhu Ning; Jiang Yong; Kato, Seizo

    2005-01-01

    This study uses ultrasound in combination with tomography to obtain three-dimensional temperature measurements using projection data obtained from limited projection angle. The main feature of the new computerized tomography (CT) reconstruction algorithm is to employ extrapolation scheme to make up for the incomplete projection data, it is based on the conventional filtered back projection (FBP) method while on top of that taking into account the correlation between the projection data and Fourier transform-based extrapolation. Computer simulation is conducted to verify the above algorithm. An experimental 3D temperature distribution measurement is also carried out to validate the proposed algorithm. The simulation and experimental results demonstrate that the extrapolated FBP CT algorithm is highly effective in dealing with projection data from limited projection angle

  13. Optimizing Opt-Out Consent for Record Linkage

    Directory of Open Access Journals (Sweden)

    Das Marcel

    2014-09-01

    Full Text Available This article reports on a study testing the effects of different ways of administering an opt-out consent for record linkage in a probability-based Internet panel. First, we conducted cognitive interviews to explore reactions to a draft version of the opt-out consent text. Second, we conducted a two-factor experiment to test the effects of content manipulations and mode. The results indicate that the way in which respondents were informed did not have much effect on opting out. Results from a follow-up survey on attitudes regarding privacy, confidentiality, and trust, along with knowledge questions about the process of linking, showed no evidence that presenting the opt-out consent statement makes respondents more concerned about privacy. Knowledge about the aspects of record linkage is generally not high. When looking at long-term effects of sending an opt-out consent statement, we found no evidence that this leads to higher attrition or lower participation rates.

  14. Neutron tomography using projection data obtained by Monte Carlo simulation for nondestructive evaluation

    International Nuclear Information System (INIS)

    Silva, A.X. da; Crispim, V.R.

    2002-01-01

    This work present the application of a computer package for generating of projection data for neutron computerized tomography, and in second part, discusses an application of neutron tomography, using the projection data obtained by Monte Carlo technique, for the detection and localization of light materials such as those containing hydrogen, concealed by heavy materials such as iron and lead. For tomographic reconstructions of the samples simulated use was made of only six equal projection angles distributed between 0 deg C and 180 deg C, with reconstruction making use of an algorithm (ARIEM), based on the principle of maximum entropy. With the neutron tomography it was possible to detect and locate polyethylene and water hidden by lead and iron (with 1 cm-thick). Thus, it is demonstrated that thermal neutrons tomography is a viable test method which can provide important interior information about test components, so, extremely useful in routine industrial applications.(author)

  15. 12 CFR 334.27 - Renewal of opt-out.

    Science.gov (United States)

    2010-01-01

    ... 12 Banks and Banking 4 2010-01-01 2010-01-01 false Renewal of opt-out. 334.27 Section 334.27 Banks and Banking FEDERAL DEPOSIT INSURANCE CORPORATION REGULATIONS AND STATEMENTS OF GENERAL POLICY FAIR CREDIT REPORTING Affiliate Marketing § 334.27 Renewal of opt-out. (a) Renewal notice and opt-out...

  16. Analysis on the Effect of Sensor Views in Image Reconstruction Produced by Optical Tomography System Using Charge-Coupled Device.

    Science.gov (United States)

    Jamaludin, Juliza; Rahim, Ruzairi Abdul; Fazul Rahiman, Mohd Hafiz; Mohd Rohani, Jemmy

    2018-04-01

    Optical tomography (OPT) is a method to capture a cross-sectional image based on the data obtained by sensors, distributed around the periphery of the analyzed system. This system is based on the measurement of the final light attenuation or absorption of radiation after crossing the measured objects. The number of sensor views will affect the results of image reconstruction, where the high number of sensor views per projection will give a high image quality. This research presents an application of charge-coupled device linear sensor and laser diode in an OPT system. Experiments in detecting solid and transparent objects in crystal clear water were conducted. Two numbers of sensors views, 160 and 320 views are evaluated in this research in reconstructing the images. The image reconstruction algorithms used were filtered images of linear back projection algorithms. Analysis on comparing the simulation and experiments image results shows that, with 320 image views giving less area error than 160 views. This suggests that high image view resulted in the high resolution of image reconstruction.

  17. Reconstruction for limited-projection fluorescence molecular tomography based on projected restarted conjugate gradient normal residual.

    Science.gov (United States)

    Cao, Xu; Zhang, Bin; Liu, Fei; Wang, Xin; Bai, Jing

    2011-12-01

    Limited-projection fluorescence molecular tomography (FMT) can greatly reduce the acquisition time, which is suitable for resolving fast biology processes in vivo but suffers from severe ill-posedness because of the reconstruction using only limited projections. To overcome the severe ill-posedness, we report a reconstruction method based on the projected restarted conjugate gradient normal residual. The reconstruction results of two phantom experiments demonstrate that the proposed method is feasible for limited-projection FMT. © 2011 Optical Society of America

  18. A randomised controlled trial to compare opt-in and opt-out parental consent for childhood vaccine safety surveillance using data linkage: study protocol

    OpenAIRE

    Berry, Jesia G; Ryan, Philip; Braunack-Mayer, Annette J; Duszynski, Katherine M; Xafis, Vicki; Gold, Michael S

    2011-01-01

    Abstract Background The Vaccine Assessment using Linked Data (VALiD) trial compared opt-in and opt-out parental consent for a population-based childhood vaccine safety surveillance program using data linkage. A subsequent telephone interview of all households enrolled in the trial elicited parental intent regarding the return or non-return of reply forms for opt-in and opt-out consent. This paper describes the rationale for the trial and provides an overview of the design and methods. Methods...

  19. A randomised controlled trial to compare opt-in and opt-out parental consent for childhood vaccine safety surveillance using data linkage: study protocol

    Directory of Open Access Journals (Sweden)

    Duszynski Katherine M

    2011-01-01

    Full Text Available Abstract Background The Vaccine Assessment using Linked Data (VALiD trial compared opt-in and opt-out parental consent for a population-based childhood vaccine safety surveillance program using data linkage. A subsequent telephone interview of all households enrolled in the trial elicited parental intent regarding the return or non-return of reply forms for opt-in and opt-out consent. This paper describes the rationale for the trial and provides an overview of the design and methods. Methods/Design Single-centre, single-blind, randomised controlled trial (RCT stratified by firstborn status. Mothers who gave birth at one tertiary South Australian hospital were randomised at six weeks post-partum to receive an opt-in or opt-out reply form, along with information explaining data linkage. The primary outcome at 10 weeks post-partum was parental participation in each arm, as indicated by the respective return or non-return of a reply form (or via telephone or email response. A subsequent telephone interview at 10 weeks post-partum elicited parental intent regarding the return or non-return of the reply form, and attitudes and knowledge about data linkage, vaccine safety, consent preferences and vaccination practices. Enrolment began in July 2009 and 1,129 households were recruited in a three-month period. Analysis has not yet been undertaken. The participation rate and selection bias for each method of consent will be compared when the data are analysed. Discussion The VALiD RCT represents the first trial of opt-in versus opt-out consent for a data linkage study that assesses consent preferences and intent compared with actual opting in or opting out behaviour, and socioeconomic factors. The limitations to generalisability are discussed. Trial registration Australian New Zealand Clinical Trials Registry ACTRN12610000332022

  20. A randomised controlled trial to compare opt-in and opt-out parental consent for childhood vaccine safety surveillance using data linkage: study protocol.

    Science.gov (United States)

    Berry, Jesia G; Ryan, Philip; Braunack-Mayer, Annette J; Duszynski, Katherine M; Xafis, Vicki; Gold, Michael S

    2011-01-04

    The Vaccine Assessment using Linked Data (VALiD) trial compared opt-in and opt-out parental consent for a population-based childhood vaccine safety surveillance program using data linkage. A subsequent telephone interview of all households enrolled in the trial elicited parental intent regarding the return or non-return of reply forms for opt-in and opt-out consent. This paper describes the rationale for the trial and provides an overview of the design and methods. Single-centre, single-blind, randomised controlled trial (RCT) stratified by firstborn status. Mothers who gave birth at one tertiary South Australian hospital were randomised at six weeks post-partum to receive an opt-in or opt-out reply form, along with information explaining data linkage. The primary outcome at 10 weeks post-partum was parental participation in each arm, as indicated by the respective return or non-return of a reply form (or via telephone or email response). A subsequent telephone interview at 10 weeks post-partum elicited parental intent regarding the return or non-return of the reply form, and attitudes and knowledge about data linkage, vaccine safety, consent preferences and vaccination practices. Enrolment began in July 2009 and 1,129 households were recruited in a three-month period. Analysis has not yet been undertaken. The participation rate and selection bias for each method of consent will be compared when the data are analysed. The VALiD RCT represents the first trial of opt-in versus opt-out consent for a data linkage study that assesses consent preferences and intent compared with actual opting in or opting out behaviour, and socioeconomic factors. The limitations to generalisability are discussed. Australian New Zealand Clinical Trials Registry ACTRN12610000332022.

  1. 40 CFR 96.85 - NOX Budget opt-in permit contents.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 20 2010-07-01 2010-07-01 false NOX Budget opt-in permit contents. 96... (CONTINUED) NOX BUDGET TRADING PROGRAM AND CAIR NOX AND SO2 TRADING PROGRAMS FOR STATE IMPLEMENTATION PLANS Individual Unit Opt-ins § 96.85 NOX Budget opt-in permit contents. (a) Each NOX Budget opt-in permit...

  2. 40 CFR 97.85 - NOX Budget opt-in permit contents.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 20 2010-07-01 2010-07-01 false NOX Budget opt-in permit contents. 97... (CONTINUED) FEDERAL NOX BUDGET TRADING PROGRAM AND CAIR NOX AND SO2 TRADING PROGRAMS Individual Unit Opt-ins. § 97.85 NOX Budget opt-in permit contents. (a) Each NOX Budget opt-in permit will contain all elements...

  3. Improving limited-projection-angle fluorescence molecular tomography using a co-registered x-ray computed tomography scan.

    Science.gov (United States)

    Radrich, Karin; Ale, Angelique; Ermolayev, Vladimir; Ntziachristos, Vasilis

    2012-12-01

    We examine the improvement in imaging performance, such as axial resolution and signal localization, when employing limited-projection-angle fluorescence molecular tomography (FMT) together with x-ray computed tomography (XCT) measurements versus stand-alone FMT. For this purpose, we employed living mice, bearing a spontaneous lung tumor model, and imaged them with FMT and XCT under identical geometrical conditions using fluorescent probes for cancer targeting. The XCT data was employed, herein, as structural prior information to guide the FMT reconstruction. Gold standard images were provided by fluorescence images of mouse cryoslices, providing the ground truth in fluorescence bio-distribution. Upon comparison of FMT images versus images reconstructed using hybrid FMT and XCT data, we demonstrate marked improvements in image accuracy. This work relates to currently disseminated FMT systems, using limited projection scans, and can be employed to enhance their performance.

  4. Nuclear energy: the cost of opting-out

    International Nuclear Information System (INIS)

    Mueller, U.

    2003-01-01

    This article discusses the results of a study made on the financial and ecological costs that would be incurred if Switzerland opted out of the use of nuclear energy. Figures are quoted for the costs if two Swiss popular initiatives on the subject of opting out of nuclear energy were accepted in voting. The disadvantages offered by the alternatives such as combined gas and steam-turbine power plant, photovoltaics and wind power are quoted. Possible negative effects of opting out on the Swiss economy are looked at and the political aspects of renewing operational permits for nuclear power stations are discussed

  5. The OptD-multi method in LiDAR processing

    International Nuclear Information System (INIS)

    Błaszczak-Bąk, Wioleta; Sobieraj-Żłobińska, Anna; Kowalik, Michał

    2017-01-01

    New and constantly developing technology for acquiring spatial data, such as LiDAR (light detection and ranging), is a source for large volume of data. However, such amount of data is not always needed for developing the most popular LiDAR products: digital terrain model (DTM) or digital surface model. Therefore, in many cases, the number of contained points are reduced in the pre-processing stage. The degree of reduction is determined by the algorithm used, which should enable the user to obtain a dataset appropriate and optimal for the planned purpose. The aim of this article is to propose a new Optimum Dataset method (OptD method) in the processing of LiDAR point clouds. The OptD method can reduce the number of points in a dataset for the specified optimization criteria concerning the characteristics of generated DTM. The OptD method can be used in two variants: OptD-single (one criterion for optimization) and OptD-multi (two or more optimization criteria). The OptD-single method has been thoroughly tested and presented by Błaszczak-Bąk (2016 Acta Geodyn. Geomater . 13/4 379–86). In this paper the authors discussed the OptD-multi method. (paper)

  6. 17 CFR 248.124 - Reasonable opportunity to opt out.

    Science.gov (United States)

    2010-04-01

    ...” to indicate their opt out preference or that requires the consumer to check one of two blank check... affiliate to make marketing solicitations to a consumer about your products or services unless the consumer... a reasonable opportunity to opt out. The consumer is given a reasonable opportunity to opt out if...

  7. 40 CFR 97.83 - Applying for NOX Budget opt-in permit.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 20 2010-07-01 2010-07-01 false Applying for NOX Budget opt-in permit... PROGRAMS (CONTINUED) FEDERAL NOX BUDGET TRADING PROGRAM AND CAIR NOX AND SO2 TRADING PROGRAMS Individual Unit Opt-ins. § 97.83 Applying for NOX Budget opt-in permit. (a) Applying for initial NO X Budget opt...

  8. Image reconstruction from projections and its application in emission computer tomography

    International Nuclear Information System (INIS)

    Kuba, Attila; Csernay, Laszlo

    1989-01-01

    Computer tomography is an imaging technique for producing cross sectional images by reconstruction from projections. Its two main branches are called transmission and emission computer tomography, TCT and ECT, resp. After an overview of the theory and practice of TCT and ECT, the first Hungarian ECT type MB 9300 SPECT consisting of a gamma camera and Ketronic Medax N computer is described, and its applications to radiological patient observations are discussed briefly. (R.P.) 28 refs.; 4 figs

  9. Multiple projection optical diffusion tomography with plane wave illumination

    International Nuclear Information System (INIS)

    Markel, Vadim A; Schotland, John C

    2005-01-01

    We describe a new data collection scheme for optical diffusion tomography in which plane wave illumination is combined with multiple projections in the slab imaging geometry. Multiple projection measurements are performed by rotating the slab around the sample. The advantage of the proposed method is that the measured data are more compatible with the dynamic range of most commonly used detectors. At the same time, multiple projections improve image quality by mutually interchanging the depth and transverse directions, and the scanned (detection) and integrated (illumination) surfaces. Inversion methods are derived for image reconstructions with extremely large data sets. Numerical simulations are performed for fixed and rotated slabs

  10. Uptake of voluntary counselling and testing among young people participating in an HIV prevention trial: comparison of opt-out and opt-in strategies.

    Directory of Open Access Journals (Sweden)

    Kathy Baisley

    Full Text Available HIV voluntary counselling and testing (VCT is an integral component of HIV prevention and treatment programmes. However, testing coverage in sub-Saharan Africa is still low, particularly among young people. As treatment becomes more widely available, strategies to expand VCT coverage are critically important. We compare VCT uptake using two delivery strategies (opt-in and opt-out within the MEMA kwa Vijana trial in 20 communities in northwest Tanzania.We analysed data from 12,590 young persons (median (IQR age 22 years (20-23 to assess the effect of delivery strategy on VCT uptake. Ten communities used an opt-in approach and 10 used opt-out, balanced across intervention and control. Conditional logistic regression was used to examine factors associated with uptake within each strategy.VCT uptake was significantly higher with the opt-out approach (90.9% vs 60.5%, prevalence ratio = 1.51, CI = 1.41-1.62. Among females, uptake in the opt-out approach was associated with decreased knowledge of HIV acquisition, sex with a casual partner, and being HSV-2 seronegative; among males, uptake was associated with lower education and increasing lifetime partners. In contrast, uptake using the opt-in approach varied by ethnic group, religion and marital status, and increased with increasing knowledge of STI acquisition (males or pregnancy prevention (females.VCT uptake among young people was extremely high when offered an opt-out strategy. Sociodemographic and knowledge factors affected uptake in different ways depending on delivery strategy. Increased knowledge may increase young persons' self-efficacy, which may have a different impact on testing uptake, depending on the approach used.

  11. 16 CFR 680.21 - Affiliate marketing opt-out and exceptions.

    Science.gov (United States)

    2010-01-01

    ... marketing purposes to a consumer with whom you have a pre-existing business relationship; (2) To facilitate... 16 Commercial Practices 1 2010-01-01 2010-01-01 false Affiliate marketing opt-out and exceptions... AFFILIATE MARKETING § 680.21 Affiliate marketing opt-out and exceptions. (a) Initial notice and opt-out...

  12. 12 CFR 717.22 - Scope and duration of opt-out.

    Science.gov (United States)

    2010-01-01

    ... CREDIT REPORTING Affiliate Marketing § 717.22 Scope and duration of opt-out. (a) Scope of opt-out. (1) In... as described in the notice to make solicitations to the consumer. (2) Continuing relationship. (i) In general. If the consumer establishes a continuing relationship with you or your affiliate, an opt-out...

  13. 12 CFR 571.22 - Scope and duration of opt-out.

    Science.gov (United States)

    2010-01-01

    ... REPORTING Affiliate Marketing § 571.22 Scope and duration of opt-out. (a) Scope of opt-out—(1) In general... described in the notice to make solicitations to the consumer. (2) Continuing relationship—(i) In general. If the consumer establishes a continuing relationship with you or your affiliate, an opt-out notice...

  14. 16 CFR 680.22 - Scope and duration of opt-out.

    Science.gov (United States)

    2010-01-01

    ... MARKETING § 680.22 Scope and duration of opt-out. (a) Scope of opt-out—(1) In general. Except as otherwise... make solicitations to the consumer. (2) Continuing relationship—(i) In general. If the consumer establishes a continuing relationship with you or your affiliate, an opt-out notice may apply to eligibility...

  15. The Diplomacy of Opting Out

    DEFF Research Database (Denmark)

    Adler-Nissen, Rebecca

    and Home Affairs. Theoretically, the study offers a political sociology of European integration, which is seen as driven by politico-administrative struggling for capital in quasi-autonomous fields. This approach can be used more generally by EU and IR scholars to understand social dynamics of inclusion...... to upholding a doxa of ‘ever closer union among the peoples of Europe'. Empirically, the thesis provides the first extensive study of the diplomatic practices of the two champions of opting out - the UK and Denmark - when they handle their most important opt-outs from the Economic Monetary Union and Justice...... the everyday social setting of international and regional governance....

  16. 12 CFR 41.22 - Scope and duration of opt-out.

    Science.gov (United States)

    2010-01-01

    ... Affiliate Marketing § 41.22 Scope and duration of opt-out. (a) Scope of opt-out. (1) In general. Except as... the notice to make solicitations to the consumer. (2) Continuing relationship. (i) In general. If the consumer establishes a continuing relationship with a bank or its affiliate, an opt-out notice may apply to...

  17. Difficult OptEase Filter Retrievals After Prolonged Indwelling Times

    Energy Technology Data Exchange (ETDEWEB)

    Van Ha, Thuong G., E-mail: tgvanha@radiology.bsd.uchicago.edu; Kang, Lisa; Lorenz, Jonathan; Zangan, Steven; Navuluri, Rakesh; Straus, Christopher; Funaki, Brian [University of Chicago, Section of Interventional Radiology, Department of Radiology (United States)

    2013-08-01

    PurposeThe OptEase vena cave filter (Cordis, Piscataway, NJ) is commercially available as a retrievable or permanent filter with short recommended indwelling time, presumably due to extensive contact of the filter side struts with the inferior vena cava wall and subsequent neointimal hyperplasia leading to incorporation. Our purpose was to evaluate OptEase filter retrievals with a long indwelling time period that required unconventional retrieval techniques.Materials and MethodsWe retrospectively reviewed patients who underwent OptEase filter retrieval with long undwelling times requiring additional maneuvers for retrieval. Techniques used included rigid endobronchial forceps dissection and wire-through-loop snare. Each patient underwent postretrieval venogram to evaluate for possible complications. In addition, patients had clinical follow-up 2 weeks after the retrieval procedure.ResultsThere were three patients (2 women, 1 man; average age 64 years) who underwent OptEase filter retrieval. The mean indwelling time was 6.4 months. The indwelling filters were successfully retrieved. There were no complications. Postprocedural follow-up showed no clinical pathology.ConclusionUnconventional techniques aided in the retrieval of OptEase filters with long indwelling times.

  18. Difficult OptEase Filter Retrievals After Prolonged Indwelling Times

    International Nuclear Information System (INIS)

    Van Ha, Thuong G.; Kang, Lisa; Lorenz, Jonathan; Zangan, Steven; Navuluri, Rakesh; Straus, Christopher; Funaki, Brian

    2013-01-01

    PurposeThe OptEase vena cave filter (Cordis, Piscataway, NJ) is commercially available as a retrievable or permanent filter with short recommended indwelling time, presumably due to extensive contact of the filter side struts with the inferior vena cava wall and subsequent neointimal hyperplasia leading to incorporation. Our purpose was to evaluate OptEase filter retrievals with a long indwelling time period that required unconventional retrieval techniques.Materials and MethodsWe retrospectively reviewed patients who underwent OptEase filter retrieval with long undwelling times requiring additional maneuvers for retrieval. Techniques used included rigid endobronchial forceps dissection and wire-through-loop snare. Each patient underwent postretrieval venogram to evaluate for possible complications. In addition, patients had clinical follow-up 2 weeks after the retrieval procedure.ResultsThere were three patients (2 women, 1 man; average age 64 years) who underwent OptEase filter retrieval. The mean indwelling time was 6.4 months. The indwelling filters were successfully retrieved. There were no complications. Postprocedural follow-up showed no clinical pathology.ConclusionUnconventional techniques aided in the retrieval of OptEase filters with long indwelling times

  19. Projection neuron circuits resolved using correlative array tomography

    Directory of Open Access Journals (Sweden)

    Daniele eOberti

    2011-04-01

    Full Text Available Assessment of three-dimensional morphological structure and synaptic connectivity is essential for a comprehensive understanding of neural processes controlling behavior. Different microscopy approaches have been proposed based on light microcopy (LM, electron microscopy (EM, or a combination of both. Correlative array tomography (CAT is a technique in which arrays of ultrathin serial sections are repeatedly stained with fluorescent antibodies against synaptic molecules and neurotransmitters and imaged with LM and EM (Micheva and Smith, 2007. The utility of this correlative approach is limited by the ability to preserve fluorescence and antigenicity on the one hand, and EM tissue ultrastructure on the other. We demonstrate tissue staining and fixation protocols and a workflow that yield an excellent compromise between these multimodal imaging constraints. We adapt CAT for the study of projection neurons between different vocal brain regions in the songbird. We inject fluorescent tracers of different colors into afferent and efferent areas of HVC in zebra finches. Fluorescence of some tracers is lost during tissue preparation but recovered using anti-dye antibodies. Synapses are identified in EM imagery based on their morphology and ultrastructure and classified into projection neuron type based on fluorescence signal. Our adaptation of array tomography, involving the use of fluorescent tracers and heavy-metal rich staining and embedding protocols for high membrane contrast in EM will be useful for research aimed at statistically describing connectivity between different projection neuron types and for elucidating how sensory signals are routed in the brain and transformed into a meaningful motor output.

  20. 75 FR 51266 - Reedsport OPT Wave Park, LLC; Notice of Settlement Agreement and Soliciting Comments

    Science.gov (United States)

    2010-08-19

    ... of Practice and Procedure, 18 CFR 385.602, Federal Power Act 16 U.S.C. 791 (a)-825(r). h. Applicant... behalf of itself; National Marine Fisheries Service; U.S. Fish and Wildlife Service; U.S. Forest Service... DEPARTMENT OF ENERGY Federal Energy Regulatory Commission [Project No. 12713-002] Reedsport OPT...

  1. Long-Term Safety and Effectiveness of the “OptEase” Vena Cava Filter

    International Nuclear Information System (INIS)

    Kalva, Sanjeeva P.; Marentis, Theodore C.; Yeddula, Kalpana; Somarouthu, Bhanusupriya; Wicky, Stephan; Stecker, Michael S.

    2011-01-01

    Purpose: To assess the long-term safety and effectiveness of the OptEase inferior vena cava (IVC) filter. Materials and Methods: In this Institutional Review Board-approved, retrospective study, we reviewed data of 71 patients who received an OptEase filter at our institution from 2002 to 2007. Thirty-nine (55%) patients had symptoms of venous thromboembolism before filter placement. The indications for filter included contraindication to anticoagulation in 31 (44%) patients, prophylaxis against pulmonary embolism (PE) in 29 (41%) patients, and failure of anticoagulation in 11 (15%) patients. Procedure-related complications, such as symptomatic post-filter PE, deep venous thrombosis (DVT), IVC occlusion, and incidental imaging-evident filter-related complications, were recorded. Safety was assessed by the occurrence of filter-related complications during placement and follow-up. Effectiveness was assessed by the occurrence of post-filter PE. Results: Sixty-five (92%) filters were placed under fluoroscopy, and 6 (8%) were placed using intravascular ultrasound guidance. Seventy (99%) filters were placed successfully. Seven (10%) filters were placed in the suprarenal cava. Retrieval was attempted in 14 (20%) patients, and 12 filters were successfully retrieved. Clinical follow-up was available for 20 ± 21 months. Symptoms of postfilter PE and DVT occurred in 15% (n = 11) and 10% (n = 7) patients, respectively. None of these patients had computed tomography (CT)-proven PE, and only one had ultrasound-proven new DVT. One patient had symptomatic IVC occlusion. Follow-up abdominal CT in 20 patients showed thrombus in the filter in two of them. There were no instances of filter migration, filter tilt, or caval wall penetration. Conclusion: The OptEase filter appears to have an acceptable long-term safety profile. The filter was effective against PE.

  2. 12 CFR 222.27 - Renewal of opt-out.

    Science.gov (United States)

    2010-01-01

    ... 12 Banks and Banking 3 2010-01-01 2010-01-01 false Renewal of opt-out. 222.27 Section 222.27 Banks and Banking FEDERAL RESERVE SYSTEM (CONTINUED) BOARD OF GOVERNORS OF THE FEDERAL RESERVE SYSTEM FAIR CREDIT REPORTING (REGULATION V) Affiliate Marketing § 222.27 Renewal of opt-out. (a) Renewal notice and...

  3. 12 CFR 717.27 - Renewal of opt-out.

    Science.gov (United States)

    2010-01-01

    ... applies. (2) Renewal period. Each opt-out renewal must be effective for a period of at least five years as... companies, or their successors, that jointly provided the previous opt-out notice. (b) Contents of renewal... provided by multiple companies with the ABC name or multiple companies in the ABC group or family of...

  4. Private International Law Issues in Opt-out and Opt-in Instruments of Harmonization

    DEFF Research Database (Denmark)

    Fogt, Morten Midtgaard

    2013-01-01

    of Goods from 1980 (CISG) and the European Commission Proposal for a common European Sales Law from 2011 (CESL). Although the two instruments of substantial harmonization regulate the same area of civil law, they differ with respect to the type of formal instrument of harmonization, the material, personal......This article deals with opt-in and opt-out instruments of harmonization, how they apply and compete. It analyses the Private International Law (PIL) issues which arise and bases the analysis on the two instruments of harmonization – the Vienna Convention on Contract for the International Sale...... into these questions and argues, inter alia, that the CISG as a global international convention should have priority over the regional CESL, that the choice of the CESL should be based on a PIL choice of binding European ‘Community rules of law’, that both instruments cannot possible overrule the established PIL...

  5. Iron deficiency regulated OsOPT7 is essential for iron homeostasis in rice.

    Science.gov (United States)

    Bashir, Khurram; Ishimaru, Yasuhiro; Itai, Reiko Nakanishi; Senoura, Takeshi; Takahashi, Michiko; An, Gynheung; Oikawa, Takaya; Ueda, Minoru; Sato, Aiko; Uozumi, Nobuyuki; Nakanishi, Hiromi; Nishizawa, Naoko K

    2015-05-01

    The molecular mechanism of iron (Fe) uptake and transport in plants are well-characterized; however, many components of Fe homeostasis remain unclear. We cloned iron-deficiency-regulated oligopeptide transporter 7 (OsOPT7) from rice. OsOPT7 localized to the plasma membrane and did not transport Fe(III)-DMA or Fe(II)-NA and GSH in Xenopus laevis oocytes. Furthermore OsOPT7 did not complement the growth of yeast fet3fet4 mutant. OsOPT7 was specifically upregulated in response to Fe-deficiency. Promoter GUS analysis revealed that OsOPT7 expresses in root tips, root vascular tissue and shoots as well as during seed development. Microarray analysis of OsOPT7 knockout 1 (opt7-1) revealed the upregulation of Fe-deficiency-responsive genes in plants grown under Fe-sufficient conditions, despite the high Fe and ferritin concentrations in shoot tissue indicating that Fe may not be available for physiological functions. Plants overexpressing OsOPT7 do not exhibit any phenotype and do not accumulate more Fe compared to wild type plants. These results indicate that OsOPT7 may be involved in Fe transport in rice.

  6. 40 CFR 96.83 - Applying for NOX Budget opt-in permit.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 20 2010-07-01 2010-07-01 false Applying for NOX Budget opt-in permit... PROGRAMS (CONTINUED) NOX BUDGET TRADING PROGRAM AND CAIR NOX AND SO2 TRADING PROGRAMS FOR STATE IMPLEMENTATION PLANS Individual Unit Opt-ins § 96.83 Applying for NOX Budget opt-in permit. (a) Applying for...

  7. 12 CFR 334.23 - Contents of opt-out notice; consolidated and equivalent notices.

    Science.gov (United States)

    2010-01-01

    ... of the joint consumers may exercise the right to opt out. (ii) The opt-out notice must explain how an...) Alternative contents. If the consumer is afforded a broader right to opt out of receiving marketing than is... a clear, conspicuous, and concise notice that accurately discloses the consumer's opt-out rights. (4...

  8. 12 CFR 222.23 - Contents of opt-out notice; consolidated and equivalent notices.

    Science.gov (United States)

    2010-01-01

    ... consumers. Any of the joint consumers may exercise the right to opt out. (ii) The opt-out notice must...) Alternative contents. If the consumer is afforded a broader right to opt out of receiving marketing than is... a clear, conspicuous, and concise notice that accurately discloses the consumer's opt-out rights. (4...

  9. 12 CFR 571.25 - Reasonable and simple methods of opting out.

    Science.gov (United States)

    2010-01-01

    ... CREDIT REPORTING Affiliate Marketing § 571.25 Reasonable and simple methods of opting out. (a) In general... out, such as a form that can be electronically mailed or processed at an Internet Web site, if the... (15 U.S.C. 6801 et seq.), the affiliate sharing opt-out under the Act, and the affiliate marketing opt...

  10. 16 CFR 680.25 - Reasonable and simple methods of opting out.

    Science.gov (United States)

    2010-01-01

    ... AFFILIATE MARKETING § 680.25 Reasonable and simple methods of opting out. (a) In general. You must not use... a form that can be electronically mailed or processed at an Internet Web site, if the consumer..., 15 U.S.C. 6801 et seq., the affiliate sharing opt-out under the Act, and the affiliate marketing opt...

  11. Sacrificio cortoplacista adaptativo 2opt (SCA_2opt: Una heurística inspirada en el pensamiento sistémico

    Directory of Open Access Journals (Sweden)

    Jorge Pérez Rave

    2014-03-01

    Full Text Available Se detalla el origen de dos noveles heurísticas para el TSP simétrico, inspiradas en el pensamiento sistémico: Sacrificio Cortoplacista Adaptativo 2-opt (SCA_2opt y SCA_2_opt_r. Estas surgen del análisis sistémico de la regla de decisión Vecino más cercano, identificándosele el arquetipo "Soluciones contraproducentes". El SCA se basa en que el agente viajero renuncie en un momento dado a una ciudad inmediatamente cercana, y se traslade hacia la segunda ciudad más cercana disponible. A partir de ello, se continúa con la regla del vecino más cercano. Cada que se realiza el SCA (búsqueda global se efectúa una búsqueda local 2_opt. Considerando el binomio eficacia y eficiencia, las dos heurísticas se muestran prometedoras en comparación multicriterio contra 19 metaheurísticas. Se evidencia que el pensamiento sistémico es un campo de inspiración viable para el desarrollo de métodos de optimización combinatoria; se plasman preguntas emergentes para desarrollos futuros, que permitan continuar integrando elementos de la optimización clásica con el pensamiento sistémico; áreas tradicionalmente vistas como antagónicas, pero cuyo diálogo se muestra favorable en este artículo.

  12. The utility of three-dimensional optical projection tomography in nerve injection injury imaging

    Czech Academy of Sciences Publication Activity Database

    Cvetko, E.; Čapek, Martin; Damjanovska, M.; Reina, M. A.; Eržen, I.; Stopar-Pintarič, T.

    2015-01-01

    Roč. 70, č. 8 (2015), s. 939-947 ISSN 0003-2409 R&D Projects: GA ČR(CZ) GA13-12412S; GA MŠk(CZ) LH13028 Institutional support: RVO:67985823 Keywords : optical projection tomography * 3D nerve visualization * nerve disruption Subject RIV: EA - Cell Biology Impact factor: 3.794, year: 2015

  13. Improving the ensemble optimization method through covariance matrix adaptation (CMA-EnOpt)

    NARCIS (Netherlands)

    Fonseca, R.M.; Leeuwenburgh, O.; Hof, P.M.J. van den; Jansen, J.D.

    2013-01-01

    Ensemble Optimization (EnOpt) is a rapidly emerging method for reservoir model based production optimization. EnOpt uses an ensemble of controls to approximate the gradient of the objective function with respect to the controls. Current implementations of EnOpt use a Gaussian ensemble with a

  14. 12 CFR 571.26 - Delivery of opt-out notices.

    Science.gov (United States)

    2010-01-01

    ... Affiliate Marketing § 571.26 Delivery of opt-out notices. (a) In general. The opt-out notice must be... the notice on the Internet Web site at which the consumer obtained a product or service electronically... on an Internet Web site without requiring the consumer to acknowledge receipt of the notice. ...

  15. 12 CFR 41.26 - Delivery of opt-out notices.

    Science.gov (United States)

    2010-01-01

    ... Affiliate Marketing § 41.26 Delivery of opt-out notices. (a) In general. The opt-out notice must be provided... the notice on the Internet Web site at which the consumer obtained a product or service electronically... on an Internet Web site without requiring the consumer to acknowledge receipt of the notice. ...

  16. On uniqueness in diffuse optical tomography

    International Nuclear Information System (INIS)

    Harrach, Bastian

    2009-01-01

    A prominent result of Arridge and Lionheart (1998 Opt. Lett. 23 882–4) demonstrates that it is in general not possible to simultaneously recover both the diffusion (aka scattering) and the absorption coefficient in steady-state (dc) diffusion-based optical tomography. In this work we show that it suffices to restrict ourselves to piecewise constant diffusion and piecewise analytic absorption coefficients to regain uniqueness. Under this condition both parameters can simultaneously be determined from complete measurement data on an arbitrarily small part of the boundary

  17. Effect of number of of projections on inverse radon transform based image reconstruction by using filtered back-projection for parallel beam transmission tomography

    International Nuclear Information System (INIS)

    Qureshi, S.A.; Mirza, S.M.; Arif, M.

    2007-01-01

    This paper present the effect of number of projections on inverse Radon transform (IRT) estimation using filtered back-projection (FBP) technique for parallel beam transmission tomography. The head phantom and the lung phantom have been used in this work. Various filters used in this study include Ram-Lak, Shepp-Logan, Cosin, Hamming and Hanning filters. The slices have been reconstructed by increasing the number of projections through parallel beam transmission tomography keeping the projections uniformly distributed. The Euclidean and Mean Squared errors and peak signal-to-noise ratio (PSNR) have been analyzed for their sensitiveness as functions of number of projections. It has found that image quality improves with the number of projections but at the cost of the computer time. The error has been minimized to get the best approximation of inverse Radon transform (IRT) as the number of projections is enhanced. The value of PSNR has been found to increase from 8.20 to 24.53 dB as the number of projections is raised from 5 to 180 for head phantom. (author)

  18. Opt-out donation and tacit consent: a reply to Wilkinson and De Wispelaere.

    Science.gov (United States)

    Saunders, Ben

    2012-02-01

    In this reply to Wilkinson and De Wispelaere, I argue that an opt-out donation system can be regarded as tacit consent. I first separate the opt-in/opt-out issue from that of the role that the family ought to play. I then argue that what De Wispelaere calls minimal approval-tracking is not obviously necessary and that, even if it were, opt-out schemes can satisfy this requirement.

  19. 17 CFR 160.7 - Form of opt out notice to consumers; opt out methods.

    Science.gov (United States)

    2010-04-01

    ... consumer agrees, electronically. (2) When a customer relationship terminates, the customer's opt out... that relationship. If the individual subsequently establishes a new customer relationship with you, the... relationships. (1) If two or more consumers jointly obtain a financial product or service from you, you may...

  20. 12 CFR 717.26 - Delivery of opt-out notices.

    Science.gov (United States)

    2010-01-01

    ... CREDIT REPORTING Affiliate Marketing § 717.26 Delivery of opt-out notices. (a) In general. The opt-out... the notice; or (4) Posts the notice on the Internet Web site at which the consumer obtained a product... notice; or (3) Posts the notice on an Internet Web site without requiring the consumer to acknowledge...

  1. 12 CFR 222.24 - Reasonable opportunity to opt out.

    Science.gov (United States)

    2010-01-01

    ... consumers to write a “yes” or “no” to indicate their opt-out preference or that requires the consumer to... opt out. (a) In general. You must not use eligibility information about a consumer that you receive from an affiliate to make a solicitation to the consumer about your products or services, unless the...

  2. 12 CFR 571.24 - Reasonable opportunity to opt out.

    Science.gov (United States)

    2010-01-01

    ... completing a form that requires consumers to write a “yes” or “no” to indicate their opt-out preference or... eligibility information about a consumer that you receive from an affiliate to make a solicitation to the consumer about your products or services, unless the consumer is provided a reasonable opportunity to opt...

  3. Assessment Opt-Out Policies: State Responses to Parent Pushback. ECS Education Trends

    Science.gov (United States)

    Aragon, Stephanie; Rowland, Julie; Wixom, Micah Ann

    2015-01-01

    With new state assessments kicking into full swing across the country, schools are seeing more and more parents wanting to opt out their children. Determining whether states allow assessment opt-outs can be complex and is constantly evolving. In some states the answer is clear: State policies either allow or prohibit state assessment opt-outs, or…

  4. The OptIPuter microscopy demonstrator: enabling science through a transatlantic lightpath.

    Science.gov (United States)

    Ellisman, M; Hutton, T; Kirkland, A; Lin, A; Lin, C; Molina, T; Peltier, S; Singh, R; Tang, K; Trefethen, A E; Wallom, D C H; Xiong, X

    2009-07-13

    The OptIPuter microscopy demonstrator project has been designed to enable concurrent and remote usage of world-class electron microscopes located in Oxford and San Diego. The project has constructed a network consisting of microscopes and computational and data resources that are all connected by a dedicated network infrastructure using the UK Lightpath and US Starlight systems. Key science drivers include examples from both materials and biological science. The resulting system is now a permanent link between the Oxford and San Diego microscopy centres. This will form the basis of further projects between the sites and expansion of the types of systems that can be remotely controlled, including optical, as well as electron, microscopy. Other improvements will include the updating of the Microsoft cluster software to the high performance computing (HPC) server 2008, which includes the HPC basic profile implementation that will enable the development of interoperable clients.

  5. The OptIPuter microscopy demonstrator: enabling science through a transatlantic lightpath

    Science.gov (United States)

    Ellisman, M.; Hutton, T.; Kirkland, A.; Lin, A.; Lin, C.; Molina, T.; Peltier, S.; Singh, R.; Tang, K.; Trefethen, A.E.; Wallom, D.C.H.; Xiong, X.

    2009-01-01

    The OptIPuter microscopy demonstrator project has been designed to enable concurrent and remote usage of world-class electron microscopes located in Oxford and San Diego. The project has constructed a network consisting of microscopes and computational and data resources that are all connected by a dedicated network infrastructure using the UK Lightpath and US Starlight systems. Key science drivers include examples from both materials and biological science. The resulting system is now a permanent link between the Oxford and San Diego microscopy centres. This will form the basis of further projects between the sites and expansion of the types of systems that can be remotely controlled, including optical, as well as electron, microscopy. Other improvements will include the updating of the Microsoft cluster software to the high performance computing (HPC) server 2008, which includes the HPC basic profile implementation that will enable the development of interoperable clients. PMID:19487201

  6. 12 CFR 717.21 - Affiliate marketing opt-out and exceptions.

    Science.gov (United States)

    2010-01-01

    ... 12 Banks and Banking 6 2010-01-01 2010-01-01 false Affiliate marketing opt-out and exceptions. 717.21 Section 717.21 Banks and Banking NATIONAL CREDIT UNION ADMINISTRATION REGULATIONS AFFECTING CREDIT UNIONS FAIR CREDIT REPORTING Affiliate Marketing § 717.21 Affiliate marketing opt-out and exceptions. (a...

  7. 12 CFR 334.22 - Scope and duration of opt-out.

    Science.gov (United States)

    2010-01-01

    ... POLICY FAIR CREDIT REPORTING Affiliate Marketing § 334.22 Scope and duration of opt-out. (a) Scope of opt... relationship—(i) In general. If the consumer establishes a continuing relationship with you or your affiliate... continuing relationship or multiple continuing relationships that the consumer establishes with you or your...

  8. Computed tomography of surface related radionuclide distributions ('BONN'-tomography)

    International Nuclear Information System (INIS)

    Bockisch, A.; Koenig, R.

    1989-01-01

    A method called the 'BONN' tomography is described to produce planar projections of circular activity distributions using standard single photon emission computed tomography. The clinical value of the method is demonstrated for bone scans of the jaw, thorax, and pelvis. Numerical or projection-related problems are discussed. (orig.) [de

  9. 12 CFR 571.21 - Affiliate marketing opt-out and exceptions.

    Science.gov (United States)

    2010-01-01

    ... solicitation for marketing purposes to a consumer with whom you have a pre-existing business relationship; (2... 12 Banks and Banking 5 2010-01-01 2010-01-01 false Affiliate marketing opt-out and exceptions. 571... CREDIT REPORTING Affiliate Marketing § 571.21 Affiliate marketing opt-out and exceptions. (a) Initial...

  10. Opt-out screening strategy for HIV infection among patients attending emergency departments: systematic review and meta-analysis.

    Science.gov (United States)

    Henriquez-Camacho, C; Villafuerte-Gutierrez, P; Pérez-Molina, J A; Losa, J; Gotuzzo, E; Cheyne, N

    2017-07-01

    International health agencies have promoted nontargeted universal (opt-out) HIV screening tests in different settings, including emergency departments (EDs). We performed a systematic review and meta-analysis to assess the testing uptake of strategies (opt-in targeted, opt-in nontargeted and opt-out) to detect new cases of HIV infection in EDs. We searched the Pubmed and Embase databases, from 1984 to April 2015, for opt-in and opt-out HIV diagnostic strategies used in EDs. Randomized controlled or quasi experimental studies were included. We assessed the percentage of positive individuals tested for HIV infection in each programme (opt-in and opt-out strategies). The mean percentage was estimated by combining studies in a random-effect meta-analysis. The percentages of individuals tested in the programmes were compared in a random-effect meta-regression model. Data were analysed using stata version 12. Quality assessments were performed using the Newcastle-Ottawa Scale. Of the 90 papers identified, 28 were eligible for inclusion. Eight trials used opt-out, 18 trials used opt-in, and two trials used both to detect new cases of HIV infection. The test was accepted and taken by 75 155 of 172 237 patients (44%) in the opt-out strategy, and 73 581 of 382 992 patients (19%) in the opt-in strategy. The prevalence of HIV infection detected by the opt-out strategy was 0.40% (373 cases), that detected by the opt-in nontargeted strategy was 0.52% (419 cases), and that detected by the opt-in targeted strategy was 1.06% (52 cases). In this meta-analysis, the testing uptake of the opt-out strategy was not different from that of the opt-in strategy to detect new cases of HIV infection in EDs. © 2016 British HIV Association.

  11. 12 CFR 334.21 - Affiliate marketing opt-out and exceptions.

    Science.gov (United States)

    2010-01-01

    ... solicitation for marketing purposes to a consumer with whom you have a pre-existing business relationship; (2... 12 Banks and Banking 4 2010-01-01 2010-01-01 false Affiliate marketing opt-out and exceptions. 334... OF GENERAL POLICY FAIR CREDIT REPORTING Affiliate Marketing § 334.21 Affiliate marketing opt-out and...

  12. Effect of quantization and interpolation of projections on the sensitivity of computerized tomography

    International Nuclear Information System (INIS)

    Vajnberg, Eh.I.; Fajngojz, M.L.

    1984-01-01

    The sources and forms of manifestation of errors in quantization and interpolation of projections in case of X-ray computerized tomography are considered and quantitative criteria of their evaluation are formulated. The dominating role of the interaction of two successive quantizations of projections - one-dimensional and two-dimensional ones is revealed. The necessity of joint optimization of the two-dimensional quantization range, expansion and form of interpolation function, quantized convolution nucleus is substantiated. The experimental results at aspect ratio of tomograms 256x256 and 480 projections are presented

  13. Assessing the impact of opt-out definitions in choice experiments

    DEFF Research Database (Denmark)

    Olsen, Søren Bøye; Campbell, Danny; Mørkbak, Morten Raun

    that this heuristic has a larger impact when the opt-out is defined as respondents own typical (perceived) purchase than when defined as a none-of-these or a provided hypothetical alternative. We consequently stress the importance for researchers to be aware of these possible implications related to the definition...... of opt-out alternatives in choice experiments....

  14. Compatibility with European law of opt-out legislation

    International Nuclear Information System (INIS)

    Feldmann, U.

    2000-01-01

    Should consensus with the utilities not be reached, Federal Minister for the Environment, Mr. Trittin, repeatedly announced to introduce opt-out legislation 'by dissent'. Both the constitutionality of such legislation and its compatibility with European law are topics of controversial debate in the literature. The decision taken by the Bavarian cabinet on February 8 in this year, to use all political and legal means against shutting down German nuclear power plants and, for this purpose, even to approach the European Commission on grounds of potential violation of European law, are reason enough to deal in more detail with the compatibility of an opt-out law with the Euratom Treaty and the EC Treaty. As the opt-out law does not yet exist, these considerations can only be of a theoretical nature. However, this is the working hypothesis assumed: Reprocessing is banned as of the entry into force of the opt-out law. This ban includes moving nuclear waste abroad for reprocessing. The peaceful use of nuclear power for electricity generation in power reactors operated for thirty years is forbidden. Older reactors may be run only for a transition period of another three years. (This includes abandoning the promotion purpose in the German Atomic Energy Act and a ban on building new power reactors). However, the operating life may be distributed in a flexible way. This contribution indicates that there are sound reasons and interesting approaches, respectively, in the literature for assuming that opting out by means of legislation, coupled with a ban on reprocessing, at least constitutes a violation of the freedom for goods and/or services. However, this cannot be derived unequivocally from either the Euratom Treaty or the EC Treaty or from rulings by the European Court of Justice. Ultimately, compatibility with European law of the ban on reprocessing can be decided only by the European Court of Justice. (orig.) [de

  15. Generalized algorithm for X-ray projections generation in cone-beam tomography

    International Nuclear Information System (INIS)

    Qin Zhongyuan; Mu Xuanqin; Wang Ping; Cai Yuanlong; Hou Chuanjian

    2002-01-01

    In order to get rid of random factors in the measurement so as to support proceeding 3D reconstruction, a general approach is presented to obtain the X-ray projections in cone-beam tomography. The phantom is firstly discretized into cubic volume through inverse transformation then a generalized projection procedure is proposed to the digitized result without concerning what the phantom exactly is. In the second step, line integrals are calculated to obtain the projection of each X-ray through accumulation of tri-linear interpolation. Considering projection angles, a rotation matrix is proposed to the X-ray source and the detector plane so projections in arbitrary angles can be got. In this approach the algorithm is easy to be extended and irregular objects can also be processed. The algorithm is implemented in Visual C++ and experiments are done using different models. Satisfactory results are obtained. It makes good preparation for the proceeding reconstruction

  16. Opt-out as an acceptable method of obtaining consent in medical research: a short report.

    LENUS (Irish Health Repository)

    Vellinga, Akke

    2011-04-06

    Abstract Background A prospective cohort study was set up to investigate a possible association between antibiotic prescribing and antibiotic resistance of E. coli urinary tract infection in the community. Participation of patients with urinary tract infection was obtained through an opt-out methodology. This short paper reports on the acceptability of the opt-out recruitment approach. Methods Participating practices (22) were requested to send a urine sample from all patients presenting with symptoms of urinary tract infection. Upon receipt of the sample in the laboratory, a letter explaining the study, an opt-out form and a freepost envelope were sent to all adult patients. A website with additional information and including an \\'opt-out\\' button was set up for the study. Results A total of 1362 urine samples were submitted by the 22 participating practices representing 1178 adult patients of whom 193 actively responded to the letter: 142 opted out by letter, 15 through the website, 2 by phone and 12 sent the letter back without indication, making a total of 171 patients or 14.5% opt-out; the remaining 22 patients (1.9%) explicitly opted in. The total group consisted of 80% women and the mean age was 50.9 years (sd 20.8). No significant differences were found between patients who participated and those who opted out in terms of age, gender or whether the urine sample was positive or not. Conclusions Overall the opt-out method was well received and participation in the study reached 85.5%. The low number of complaints (2) indicates that this is a generally acceptable method of patient recruitment. The 14.5% opt-out shows that it effectively empowers patients to decline participation. The similarity between patients opting out and the rest of the patients is reassuring for extrapolation of the results of the study.

  17. Projection matrix acquisition for cone-beam computed tomography iterative reconstruction

    Science.gov (United States)

    Yang, Fuqiang; Zhang, Dinghua; Huang, Kuidong; Shi, Wenlong; Zhang, Caixin; Gao, Zongzhao

    2017-02-01

    Projection matrix is an essential and time-consuming part in computed tomography (CT) iterative reconstruction. In this article a novel calculation algorithm of three-dimensional (3D) projection matrix is proposed to quickly acquire the matrix for cone-beam CT (CBCT). The CT data needed to be reconstructed is considered as consisting of the three orthogonal sets of equally spaced and parallel planes, rather than the individual voxels. After getting the intersections the rays with the surfaces of the voxels, the coordinate points and vertex is compared to obtain the index value that the ray traversed. Without considering ray-slope to voxel, it just need comparing the position of two points. Finally, the computer simulation is used to verify the effectiveness of the algorithm.

  18. General k-opt submoves for the Lin-Kernighan TSP heuristic

    DEFF Research Database (Denmark)

    Helsgaun, Keld

    2009-01-01

    Local search with k-exchange neighborhoods, k-opt, is the most widely used heuristic method for the traveling salesman problem (TSP). This paper presents an effective implementation of k-opt in LKH-2, a variant of the Lin–Kernighan TSP heuristic. The effectiveness of the implementation...

  19. 12 CFR 334.25 - Reasonable and simple methods of opting out.

    Science.gov (United States)

    2010-01-01

    ... STATEMENTS OF GENERAL POLICY FAIR CREDIT REPORTING Affiliate Marketing § 334.25 Reasonable and simple methods... or processed at an Internet Web site, if the consumer agrees to the electronic delivery of... opt-out under the Act, and the affiliate marketing opt-out under the Act, by a single method, such as...

  20. 12 CFR 222.25 - Reasonable and simple methods of opting out.

    Science.gov (United States)

    2010-01-01

    ... FEDERAL RESERVE SYSTEM FAIR CREDIT REPORTING (REGULATION V) Affiliate Marketing § 222.25 Reasonable and... electronically mailed or processed at an Internet Web site, if the consumer agrees to the electronic delivery of... opt-out under the Act, and the affiliate marketing opt-out under the Act, by a single method, such as...

  1. Analytical simulation platform describing projections in computed tomography systems

    International Nuclear Information System (INIS)

    Youn, Hanbean; Kim, Ho Kyung

    2013-01-01

    To reduce the patient dose, several approaches such as spectral imaging using photon counting detectors and statistical image reconstruction, are being considered. Although image-reconstruction algorithms may significantly enhance image quality in reconstructed images with low dose, true signal-to-noise properties are mainly determined by image quality in projections. We are developing an analytical simulation platform describing projections to investigate how quantum-interaction physics in each component configuring CT systems affect image quality in projections. This simulator will be very useful for an improved design or optimization of CT systems in economy as well as the development of novel image-reconstruction algorithms. In this study, we present the progress of development of the simulation platform with an emphasis on the theoretical framework describing the generation of projection data. We have prepared the analytical simulation platform describing projections in computed tomography systems. The remained further study before the meeting includes the following: Each stage in the cascaded signal-transfer model for obtaining projections will be validated by the Monte Carlo simulations. We will build up energy-dependent scatter and pixel-crosstalk kernels, and show their effects on image quality in projections and reconstructed images. We will investigate the effects of projections obtained from various imaging conditions and system (or detector) operation parameters on reconstructed images. It is challenging to include the interaction physics due to photon-counting detectors into the simulation platform. Detailed descriptions of the simulator will be presented with discussions on its performance and limitation as well as Monte Carlo validations. Computational cost will also be addressed in detail. The proposed method in this study is simple and can be used conveniently in lab environment

  2. CiOpt: a program for optimization of the frequency response of linear circuits

    OpenAIRE

    Miró Sans, Joan Maria; Palà Schönwälder, Pere

    1991-01-01

    An interactive personal-computer program for optimizing the frequency response of linear lumped circuits (CiOpt) is presented. CiOpt has proved to be an efficient tool in improving designs where the inclusion of more accurate device models distorts the desired frequency response, as well as in device modeling. The outputs of CiOpt are the element values which best match the obtained and the desired frequency response. The optimization algorithms used (the Fletcher-Powell and Newton's methods,...

  3. Opt-out of voluntary HIV testing: a Singapore hospital's experience.

    Science.gov (United States)

    Chua, Arlene C; Leo, Yee Sin; Cavailler, Philippe; Chu, Christine; Ng, Aloysius; Ng, Oon Tek; Krishnan, Prabha

    2012-01-01

    Since 2008, the Singapore Ministry of Health (MOH) has expanded HIV testing by increasing anonymous HIV test sites, as well as issuing a directive to hospitals to offer routine voluntary opt out inpatient HIV testing. We reviewed this program implemented at the end of 2008 at Tan Tock Seng Hospital (TTSH), the second largest acute care general hospital in Singapore. From January 2009 to December 2010, all inpatients aged greater or equal than 21 years were screened for HIV unless they declined or were not eligible for screening. We reviewed the implementation of the Opt Out testing policy. There were a total of 93,211 admissions; 41,543 patients were included based on HIV screening program eligibility criteria. Among those included, 79% (n = 32,675) opted out of HIV screening. The overall acceptance rate was 21%. Majority of eligible patients who were tested (63%) were men. The mean age of tested patients was 52 years. The opt out rate was significantly higher among females (OR: 1.5, 95%CI: 1.4-1.6), aged >60 years (OR: 2.3, 95%CI: 2.2-2.4) and Chinese ethnicity (OR: 1.7, 95%CI:1.6-1.8). The false positive rate of the HIV screening test is 0.56%. The proportion of patients with HIV infection among those who underwent HIV screening is 0.18%. All 16 confirmed HIV patients were linked to care. The default opt-in rate of inpatient HIV testing was low at Tan Tock Seng Hospital, Singapore. Efforts to address individual HIV risk perception and campaigns against HIV stigma are needed to encourage more individuals to be tested for HIV.

  4. Augmenting short cheap talk scripts with a repeated opt-out reminder in choice experiment surveys

    DEFF Research Database (Denmark)

    Ladenburg, Jacob; Olsen, Søren Bøye

    to choose the opt-out alternative if they find the experimentally designed alternatives too expensive. In an empirical Choice Experiment survey we find the Opt-Out Reminder to significantly reduce total WTP and to some extent also marginal WTP beyond the capability of the Cheap Talk applied without the Opt...

  5. Meaning of Interior Tomography

    Science.gov (United States)

    Wang, Ge; Yu, Hengyong

    2013-01-01

    The classic imaging geometry for computed tomography is for collection of un-truncated projections and reconstruction of a global image, with the Fourier transform as the theoretical foundation that is intrinsically non-local. Recently, interior tomography research has led to theoretically exact relationships between localities in the projection and image spaces and practically promising reconstruction algorithms. Initially, interior tomography was developed for x-ray computed tomography. Then, it has been elevated as a general imaging principle. Finally, a novel framework known as “omni-tomography” is being developed for grand fusion of multiple imaging modalities, allowing tomographic synchrony of diversified features. PMID:23912256

  6. Opt-out of voluntary HIV testing: a Singapore hospital's experience.

    Directory of Open Access Journals (Sweden)

    Arlene C Chua

    Full Text Available INTRODUCTION: Since 2008, the Singapore Ministry of Health (MOH has expanded HIV testing by increasing anonymous HIV test sites, as well as issuing a directive to hospitals to offer routine voluntary opt out inpatient HIV testing. We reviewed this program implemented at the end of 2008 at Tan Tock Seng Hospital (TTSH, the second largest acute care general hospital in Singapore. METHODS AND FINDINGS: From January 2009 to December 2010, all inpatients aged greater or equal than 21 years were screened for HIV unless they declined or were not eligible for screening. We reviewed the implementation of the Opt Out testing policy. There were a total of 93,211 admissions; 41,543 patients were included based on HIV screening program eligibility criteria. Among those included, 79% (n = 32,675 opted out of HIV screening. The overall acceptance rate was 21%. Majority of eligible patients who were tested (63% were men. The mean age of tested patients was 52 years. The opt out rate was significantly higher among females (OR: 1.5, 95%CI: 1.4-1.6, aged >60 years (OR: 2.3, 95%CI: 2.2-2.4 and Chinese ethnicity (OR: 1.7, 95%CI:1.6-1.8. The false positive rate of the HIV screening test is 0.56%. The proportion of patients with HIV infection among those who underwent HIV screening is 0.18%. All 16 confirmed HIV patients were linked to care. CONCLUSION: The default opt-in rate of inpatient HIV testing was low at Tan Tock Seng Hospital, Singapore. Efforts to address individual HIV risk perception and campaigns against HIV stigma are needed to encourage more individuals to be tested for HIV.

  7. Projection model for flame chemiluminescence tomography based on lens imaging

    Science.gov (United States)

    Wan, Minggang; Zhuang, Jihui

    2018-04-01

    For flame chemiluminescence tomography (FCT) based on lens imaging, the projection model is essential because it formulates the mathematical relation between the flame projections captured by cameras and the chemiluminescence field, and, through this relation, the field is reconstructed. This work proposed the blurry-spot (BS) model, which takes more universal assumptions and has higher accuracy than the widely applied line-of-sight model. By combining the geometrical camera model and the thin-lens equation, the BS model takes into account perspective effect of the camera lens; by combining ray-tracing technique and Monte Carlo simulation, it also considers inhomogeneous distribution of captured radiance on the image plane. Performance of these two models in FCT was numerically compared, and results showed that using the BS model could lead to better reconstruction quality in wider application ranges.

  8. 12 CFR 573.15 - Other exceptions to notice and opt out requirements.

    Science.gov (United States)

    2010-01-01

    ... consumer. (2) A consumer may revoke consent by subsequently exercising the right to opt out of future... PRIVACY OF CONSUMER FINANCIAL INFORMATION Exceptions § 573.15 Other exceptions to notice and opt out... consumer, provided that the consumer has not revoked the consent or direction; (2)(i) To protect the...

  9. Tomography

    International Nuclear Information System (INIS)

    Barrett, H.H.; Gordon, S.; Swindell, W.

    1980-01-01

    Apparatus is described for generating a two-dimensional back-projected image of a slice of an object in tomography. The apparatus uses optical techniques to perform the functions of filtering and back projection. Central to the technique is a cylindrical drum which rotates at a fast rate and whose rotational axis tilts at a slower rate. The novel method overcomes the problem of image blurring due to motion which occurs in many tomographic techniques. It also has the advantages of being less expensive and simpler compared to tomography using digital processing techniques which require fast computers. (UK)

  10. Objective Provision Tree (OPT) in sodium cooled fast reactors; Objective Provision Tree (OPT) en reactores rapidos refrigerados por sodio. Aplicacion a la funcion de seguridad de evacuacion de calor residual

    Energy Technology Data Exchange (ETDEWEB)

    Queral, C.; Montero-Mayorga, J.; Gonzalez-Cadelo, J.

    2013-07-01

    Application to the safety function of residual heat removal As part of the project {sup S}afety Assessment for Reactor of GEN-IV (SARGEN IV) has been implemented the methodology ISAM from the IAEA to the safety assessment of new sodium reactor designs. Within the ISAM, a new tool to facilitate this assessment is the Objective Provision Tree (OPT) which documents the provisions necessary for each of the levels of defense in depth, as well as for each critical function of security. Due to the design innovations that have sodium reactors, the evaluation of safety and licensing of these reactors requires special considerations. In this work we have analyzed the mechanisms of failure of the safety function concerning the evacuation of waste heat, and have been proposed different provisions for each of the first three levels of defense in depth. The main result of this work is reflected in the elaboration of the OPTs, one for each of the first three levels of defense in depth for the safety of evacuation of residual heat function. These trees represent in a schematic way the provisions necessary to comply with the objectives of each level which are respectively: 1) deviations from normal operation, 2) control of abnormal operation and fault detection and 3) incidental control.

  11. Health-care providers' experiences with opt-out HIV testing: a systematic review.

    Science.gov (United States)

    Leidel, Stacy; Wilson, Sally; McConigley, Ruth; Boldy, Duncan; Girdler, Sonya

    2015-01-01

    HIV is now a manageable chronic disease with a good prognosis, but early detection and referral for treatment are vital. In opt-out HIV testing, patients are informed that they will be tested unless they decline. This qualitative systematic review explored the experiences, attitudes, barriers, and facilitators of opt-out HIV testing from a health-care provider (HCP) perspective. Four articles were included in the synthesis and reported on findings from approximately 70 participants, representing diverse geographical regions and a range of human development status and HIV prevalence. Two synthesized findings emerged: HCP attitudes and systems. The first synthesized finding encompassed HCP decision-making attitudes about who and when to test for HIV. It also included the assumptions the HCPs made about patient consequences. The second synthesized finding related to systems. System-related barriers to opt-out HIV testing included lack of time, resources, and adequate training. System-related facilitators included integration into standard practice, support of the medical setting, and electronic reminders. A common attitude among HCPs was the outdated notion that HIV is a terrible disease that equates to certain death. Some HCPs stated that offering the HIV test implied that the patient had engaged in immoral behaviour, which could lead to stigma or disengagement with health services. This paternalism diminished patient autonomy, because patients who were excluded from opt-out HIV testing could have benefited from it. One study highlighted the positive aspects of opt-out HIV testing, in which participants underscored the professional satisfaction that arose from making an HIV diagnosis, particularly when marginalized patients could be connected to treatment and social services. Recommendations for opt-out HIV testing should be disseminated to HCPs in a broad range of settings. Implementation of system-related factors such as electronic reminders and care coordination

  12. Legal issues associated with opting out of the use of nuclear power

    International Nuclear Information System (INIS)

    Butzke, K.; Storr, S.

    2000-01-01

    The article is a summary of a conference held at Jena University at which the political issues of opting out of using nuclear power were scrutinized under aspects of (constitutional) law. The results of the conference were summed up in the Jena Theses about Opting out of the use of Nuclear Power. (orig.) [de

  13. 'We didn't have to dance around it': opt-out HIV testing among homeless and marginalised patients.

    Science.gov (United States)

    Leidel, Stacy; Leslie, Gavin; Boldy, Duncan; Davies, Andrew; Girdler, Sonya

    2017-07-01

    This study explored opt-out HIV testing in an Australian general practice. The aims were to: (1) determine the effect of the opt-out approach on the number of HIV tests performed; and (2) explore the acceptability of opt-out HIV testing from the healthcare providers' perspective. A prospective mixed-methods study of opt-out HIV testing over a 2-year period (March 2014-March 2016) was conducted. Implementation was based on a theoretical framework that was developed specifically for this study. The setting was Homeless Healthcare, a health service in Perth, Western Australia. The number of HIV tests conducted during the control year (usual practice) was compared with the intervention year (opt-out testing). After the intervention, the healthcare providers (n=8) were interviewed about their experiences with opt-out HIV testing. Directed content analysis was used to explore the qualitative data. HIV testing rates were low during both the control year and the intervention year (315 HIV tests (12% of the patient cohort) and 344 HIV tests (10%) respectively). Opt-out HIV testing was feasible and acceptable to the participating healthcare providers. Other health services could consider opt-out HIV testing for their patients to identify people with undiagnosed infections and sustain Australia's low HIV prevalence.

  14. Standards, Assessments & Opting Out, Spring 2015

    Science.gov (United States)

    Advance Illinois, 2015

    2015-01-01

    In the spring, Illinois students will take new state assessments that reflect the rigor and relevance of the new Illinois Learning Standards. But some classmates will sit out and join the pushback against standardized testing. Opt-out advocates raise concerns about over-testing, and the resulting toll on students as well as the impact on classroom…

  15. 12 CFR 716.15 - Other exceptions to notice and opt out requirements.

    Science.gov (United States)

    2010-01-01

    ... insurance to the consumer. (2) A consumer may revoke consent by subsequently exercising the right to opt out... AFFECTING CREDIT UNIONS PRIVACY OF CONSUMER FINANCIAL INFORMATION Exceptions § 716.15 Other exceptions to... notice to consumers in § 716.4(a)(2), the opt out in §§ 716.7 and 716.10 and service providers and joint...

  16. An Effective Implementation of K-opt Moves for the Lin-Kernighan TSP Heuristic

    DEFF Research Database (Denmark)

    Helsgaun, Keld

    Local search with k-change neighborhoods, k-opt, is the most widely used heuristic method for the traveling salesman problem (TSP). This report presents an effective implementation of k-opt for the Lin- Kernighan TSP heuristic. The effectiveness of the implementation is demonstrated with extensive...

  17. Rethinking HIV exceptionalism: the ethics of opt-out HIV testing in sub-Saharan Africa

    Science.gov (United States)

    2010-01-01

    Abstract Opt-out testing for the human immunodeficiency virus (HIV) incorporates testing as a routine part of health care for all patients unless they refuse. The ethics of this approach to testing in sub-Saharan Africa is a source of controversy. Opt-out HIV testing is expected to improve survival by increasing case detection and thus linking more HIV-infected people to earlier treatment, provided there is effective patient follow-up and programme sustainability. At the population level, these benefits will likely outweigh the potential negative consequences of individuals experiencing HIV-related stigma. These justifications appeal to consequentialist moral theories that the acceptability of an action depends upon its outcomes. On the other hand, liberal moral theories state that the autonomy of individuals should always be protected unless restricting autonomy is necessary to protect the welfare of others. Opt-out consent may restrict autonomy and it is unclear whether it would benefit people other than those being tested. Yet, the doctrine of libertarian paternalism proposes that it is justifiable and desirable to use unobtrusive mechanisms to help individuals make choices to maximize their own welfare. Central to this idea are the premises featured by supporters of opt-out consent that individuals will not always make the best choices for their own welfare but they may be influenced to do so in ways that will not compromise their freedom of choice. Also important is the premise that all policies inevitably exert some such influence: opt-in consent encourages test refusal just as opt-out consent encourages acceptance. Based on these premises, opt-out testing may be an effective and ethically acceptable policy response to Africa’s HIV epidemic. PMID:20865076

  18. Rethinking HIV exceptionalism: the ethics of opt-out HIV testing in sub-Saharan Africa.

    Science.gov (United States)

    April, Michael D

    2010-09-01

    Opt-out testing for the human immunodeficiency virus (HIV) incorporates testing as a routine part of health care for all patients unless they refuse. The ethics of this approach to testing in sub-Saharan Africa is a source of controversy. Opt-out HIV testing is expected to improve survival by increasing case detection and thus linking more HIV-infected people to earlier treatment, provided there is effective patient follow-up and programme sustainability. At the population level, these benefits will likely outweigh the potential negative consequences of individuals experiencing HIV-related stigma. These justifications appeal to consequentialist moral theories that the acceptability of an action depends upon its outcomes. On the other hand, liberal moral theories state that the autonomy of individuals should always be protected unless restricting autonomy is necessary to protect the welfare of others. Opt-out consent may restrict autonomy and it is unclear whether it would benefit people other than those being tested. Yet, the doctrine of libertarian paternalism proposes that it is justifiable and desirable to use unobtrusive mechanisms to help individuals make choices to maximize their own welfare. Central to this idea are the premises featured by supporters of opt-out consent that individuals will not always make the best choices for their own welfare but they may be influenced to do so in ways that will not compromise their freedom of choice. Also important is the premise that all policies inevitably exert some such influence: opt-in consent encourages test refusal just as opt-out consent encourages acceptance. Based on these premises, opt-out testing may be an effective and ethically acceptable policy response to Africa's HIV epidemic.

  19. Deemed consent: Assessing the new opt-out approach to organ procurement in Wales

    DEFF Research Database (Denmark)

    Albertsen, Andreas

    2018-01-01

    In December 2015, Wales became the first country in the UK to move away from an opt-in system in organ procurement. The new legislation introduces the concept of deemed consent whereby a person who neither opt in nor opt out is deemed to have consented to donation. The data released by the National...... Health Service (NHS) in July 2017 provide an excellent opportunity to assess this legislation in light of concerns that it would decrease procurement rates for living and deceased donation, as well as sparking an increase in family refusals. None of these concerns have come to pass, with Wales...

  20. OPT13B and OPTIM4 - computer codes for optical model calculations

    International Nuclear Information System (INIS)

    Pal, S.; Srivastava, D.K.; Mukhopadhyay, S.; Ganguly, N.K.

    1975-01-01

    OPT13B is a computer code in FORTRAN for optical model calculations with automatic search. A summary of different formulae used for computation is given. Numerical methods are discussed. The 'search' technique followed to obtain the set of optical model parameters which produce best fit to experimental data in a least-square sense is also discussed. Different subroutines of the program are briefly described. Input-output specifications are given in detail. A modified version of OPT13B specifications are given in detail. A modified version of OPT13B is OPTIM4. It can be used for optical model calculations where the form factors of different parts of the optical potential are known point by point. A brief description of the modifications is given. (author)

  1. 17 CFR 248.123 - Contents of opt out notice; consolidated and equivalent notices.

    Science.gov (United States)

    2010-04-01

    ... EXCHANGE COMMISSION (CONTINUED) REGULATIONS S-P AND S-AM Regulation S-AM: Limitations on Affiliate Marketing § 248.123 Contents of opt out notice; consolidated and equivalent notices. (a) Contents of opt out...) The name of the affiliate(s) providing the notice. If the notice is provided jointly by multiple...

  2. OPT-TWO: Calculation code for two-dimensional MOX fuel models in the optimum concentration distribution

    International Nuclear Information System (INIS)

    Sato, Shohei; Okuno, Hiroshi; Sakai, Tomohiro

    2007-08-01

    OPT-TWO is a calculation code which calculates the optimum concentration distribution, i.e., the most conservative concentration distribution in the aspect of nuclear criticality safety, of MOX (mixed uranium and plutonium oxide) fuels in the two-dimensional system. To achieve the optimum concentration distribution, we apply the principle of flattened fuel importance distribution with which the fuel system has the highest reactivity. Based on this principle, OPT-TWO takes the following 3 calculation steps iteratively to achieve the optimum concentration distribution with flattened fuel importance: (1) the forward and adjoint neutron fluxes, and the neutron multiplication factor, with TWOTRAN code which is a two-dimensional neutron transport code based on the SN method, (2) the fuel importance, and (3) the quantity of the transferring fuel. In OPT-TWO, the components of MOX fuel are MOX powder, uranium dioxide powder and additive. This report describes the content of the calculation, the computational method, and the installation method of the OPT-TWO, and also describes the application method of the criticality calculation of OPT-TWO. (author)

  3. The MOZART Project - MOZAmbique Rift Tomography

    Science.gov (United States)

    Fonseca, J. F.; Chamussa, J. R.; Domingues, A.; Helffrich, G. R.; Fishwick, S.; Ferreira, A. M.; Custodio, S.; Brisbourne, A. M.; Grobbelaar, M.

    2012-12-01

    Project MOZART (MOZAmbique Rift Tomography) is an ongoing joint effort of Portuguese, Mozambican and British research groups to investigate the geological structure and current tectonic activity of the southernmost tip of the East African Rift System (EARS) through the deployment of a network of 30 broad band seismic stations in Central and Southern Mozambique. In contrast with other stretches of the EARS to the North and with the Kapvaal craton to the West and South, the lithosphere of Mozambique was not previously studied with a dense seismographic deployment on account of past political instability, and many questions remain unanswered with respect to the location and characteristics of the EARS to the south of Tanzania. In recent years, space geodesy revealed the existence of three microplates in and off Mozambique - Victoria, Rovuma, Lwandle - whose borders provide a connection of the EARS to the South West Indian Ridge as required by plate tectonics. However, the picture is still coarse concerning the location of the rift structures. The 2006 M7 Machaze earthquake in Central Mozambique highlighted the current tectonic activity of the region and added a further clue to the location of the continental rift, prompting the MOZART deployment. Besides helping unravel the current tectonics, the project is expected to shed light on the poorly known Mesoproterozoic structure described by Arthur Holmes in 1951 as the Mozambique Belt, and on the mechanisms of transition from stable craton to rifted continental crust, through the development of a tomographic model for the lithosphere. The MOZART network is distributed South of the Zambezi river at average inter-station spaces of the order of 100 km and includes four stations across the border in South Africa. Data exchange was agreed with AfricaArray. The deployment proceeded in two phases in March 2011, and November and December 2011. Decommissioning is foreseen for August 2013. We report preliminary results for this

  4. submitter The Muon Portal Project: Design and construction of a scanning portal based on muon tomography

    CERN Document Server

    Antonuccio, V; Becciani, U; Bonanno, D L; Bonanno, G; Bongiovanni, D; Fallica, P G; Garozzo, S; Grillo, A; La Rocca, P; Leonora, E; Longhitano, F; Lo Presti, D; Marano, D; Parasole, O; Pugliatti, C; Randazzo, N; Riggi, F; Riggi, S; Romeo, G; Romeo, M; Russo, G V; Santagati, G; Timpanaro, M C; Valvo, G

    2017-01-01

    Cosmic ray tomography is a technique which exploits the multiple Coulomb scattering of highly penetrating cosmic ray-produced muons to perform non-destructive inspection of high-Z materials without the use of artificial radiation. A muon tomography detection system can be used as a portal monitor at border crossing points for detecting illegal targeted objects. The Muon Portal Project is a joint initiative between Italian research and industrial partners, aimed at the construction of a real size detector prototype $(6×3×7 m^3)$ for the inspection of cargo containers by the muon scattering technique. The detector consists of four XY tracking planes, two placed above and two below the container to be inspected. After a research and development phase, which led to the choice and test of the individual components, the construction and installation of the detection modules is almost completed. In this paper the present status of the Project is reported, focusing on the design and construction phase, as well as o...

  5. The Muon Portal Project: Design and construction of a scanning portal based on muon tomography

    Energy Technology Data Exchange (ETDEWEB)

    Antonuccio, V. [INAF - Osservatorio Astrofisico di Catania (Italy); Bandieramonte, M. [CERN, Geneva (Switzerland); Becciani, U. [INAF - Osservatorio Astrofisico di Catania (Italy); Bonanno, D.L., E-mail: danilo.bonanno@ct.infn.it [INFN Sezione di Catania, Catania (Italy); Bonanno, G. [INAF - Osservatorio Astrofisico di Catania (Italy); Bongiovanni, D. [INFN Sezione di Catania, Catania (Italy); Fallica, P.G. [STMicroelectronics, Catania (Italy); Garozzo, S.; Grillo, A. [INAF - Osservatorio Astrofisico di Catania (Italy); La Rocca, P. [INFN Sezione di Catania, Catania (Italy); Dipartimento di Fisica e Astronomia, Università di Catania, Catania (Italy); Leonora, E.; Longhitano, F. [INFN Sezione di Catania, Catania (Italy); Lo Presti, D. [INFN Sezione di Catania, Catania (Italy); Dipartimento di Fisica e Astronomia, Università di Catania, Catania (Italy); Marano, D. [INAF - Osservatorio Astrofisico di Catania (Italy); Parasole, O. [INFN Sezione di Catania, Catania (Italy); Dipartimento di Fisica e Astronomia, Università di Catania, Catania (Italy); Pugliatti, C. [Dipartimento di Fisica e Astronomia, Università di Catania, Catania (Italy); Randazzo, N. [INFN Sezione di Catania, Catania (Italy); Riggi, F. [INFN Sezione di Catania, Catania (Italy); Dipartimento di Fisica e Astronomia, Università di Catania, Catania (Italy); Riggi, S. [INAF - Osservatorio Astrofisico di Catania (Italy); INFN Sezione di Catania, Catania (Italy); Romeo, G. [INAF - Osservatorio Astrofisico di Catania (Italy); and others

    2017-02-11

    Cosmic ray tomography is a technique which exploits the multiple Coulomb scattering of highly penetrating cosmic ray-produced muons to perform non-destructive inspection of high-Z materials without the use of artificial radiation. A muon tomography detection system can be used as a portal monitor at border crossing points for detecting illegal targeted objects. The Muon Portal Project is a joint initiative between Italian research and industrial partners, aimed at the construction of a real size detector prototype (6×3×7 m{sup 3}) for the inspection of cargo containers by the muon scattering technique. The detector consists of four XY tracking planes, two placed above and two below the container to be inspected. After a research and development phase, which led to the choice and test of the individual components, the construction and installation of the detection modules is almost completed. In this paper the present status of the Project is reported, focusing on the design and construction phase, as well as on the preliminary results obtained with the first detection planes.

  6. The Muon Portal Project: Design and construction of a scanning portal based on muon tomography

    Science.gov (United States)

    Antonuccio, V.; Bandieramonte, M.; Becciani, U.; Bonanno, D. L.; Bonanno, G.; Bongiovanni, D.; Fallica, P. G.; Garozzo, S.; Grillo, A.; La Rocca, P.; Leonora, E.; Longhitano, F.; Lo Presti, D.; Marano, D.; Parasole, O.; Pugliatti, C.; Randazzo, N.; Riggi, F.; Riggi, S.; Romeo, G.; Romeo, M.; Russo, G. V.; Santagati, G.; Timpanaro, M. C.; Valvo, G.

    2017-02-01

    Cosmic ray tomography is a technique which exploits the multiple Coulomb scattering of highly penetrating cosmic ray-produced muons to perform non-destructive inspection of high-Z materials without the use of artificial radiation. A muon tomography detection system can be used as a portal monitor at border crossing points for detecting illegal targeted objects. The Muon Portal Project is a joint initiative between Italian research and industrial partners, aimed at the construction of a real size detector prototype (6×3×7 m3) for the inspection of cargo containers by the muon scattering technique. The detector consists of four XY tracking planes, two placed above and two below the container to be inspected. After a research and development phase, which led to the choice and test of the individual components, the construction and installation of the detection modules is almost completed. In this paper the present status of the Project is reported, focusing on the design and construction phase, as well as on the preliminary results obtained with the first detection planes.

  7. A reconstruction algorithm for coherent scatter computed tomography based on filtered back-projection

    International Nuclear Information System (INIS)

    Stevendaal, U. van; Schlomka, J.-P.; Harding, A.; Grass, M.

    2003-01-01

    Coherent scatter computed tomography (CSCT) is a reconstructive x-ray imaging technique that yields the spatially resolved coherent-scatter form factor of the investigated object. Reconstruction from coherently scattered x-rays is commonly done using algebraic reconstruction techniques (ART). In this paper, we propose an alternative approach based on filtered back-projection. For the first time, a three-dimensional (3D) filtered back-projection technique using curved 3D back-projection lines is applied to two-dimensional coherent scatter projection data. The proposed algorithm is tested with simulated projection data as well as with projection data acquired with a demonstrator setup similar to a multi-line CT scanner geometry. While yielding comparable image quality as ART reconstruction, the modified 3D filtered back-projection algorithm is about two orders of magnitude faster. In contrast to iterative reconstruction schemes, it has the advantage that subfield-of-view reconstruction becomes feasible. This allows a selective reconstruction of the coherent-scatter form factor for a region of interest. The proposed modified 3D filtered back-projection algorithm is a powerful reconstruction technique to be implemented in a CSCT scanning system. This method gives coherent scatter CT the potential of becoming a competitive modality for medical imaging or nondestructive testing

  8. Presentations from the Aeroelastic Workshop - latest results from AeroOpt

    Energy Technology Data Exchange (ETDEWEB)

    Hartvig Hansen, M. (ed.)

    2011-10-15

    This report contains the slides of the presentations at the Aeroelastic Workshop held at Risoe-DTU for the wind energy industry in Denmark on October 27, 2011. The scientific part of the agenda at this workshop was 1) Detailed and reduced models of dynamic mooring system (Anders M. Hansen). 2) Bend-twist coupling investigation in HAWC2 (Taeseong Kim). 3) Q3UIC - A new aerodynamic airfoil tool including rotational effects (Nestor R. Garcia). 4) Influence of up-scaling on loads, control and aerodynamic modeling (Helge Aa. Madsen). 5) Aerodynamic damping of lateral tower vibrations (Bjarne S. Kallesoee). 6) Open- and closed-loop aeroservoelastic analysis with HAWCStab2 (Morten H. Hansen). 7) Design and test of a thick, flatback, high-lift multielement airfoil (Frederik Zahle). The presented results are mainly obtained in the EUDP project ''Aeroelastic Optimization of MW Wind Turbines (AeroOpt)''. (Author)

  9. Total Variation-Based Reduction of Streak Artifacts, Ring Artifacts and Noise in 3D Reconstruction from Optical Projection Tomography

    Czech Academy of Sciences Publication Activity Database

    Michálek, Jan

    2015-01-01

    Roč. 21, č. 6 (2015), s. 1602-1615 ISSN 1431-9276 R&D Projects: GA MŠk(CZ) LH13028; GA ČR(CZ) GA13-12412S Institutional support: RVO:67985823 Keywords : optical projection tomography * microscopy * artifacts * total variation * data mismatch Subject RIV: EA - Cell Biology Impact factor: 1.730, year: 2015

  10. The Opt-Out Continuation: Education, Work, and Motherhood from 1984 to 2012

    Directory of Open Access Journals (Sweden)

    Tanya Byker

    2016-08-01

    Full Text Available Debate about an increasing trend in highly educated women dropping out of the labor force to care for children—an opt-out revolution—has been considerable. I use unique features of the of Survey of Income and Program Participation—a large nationally representative sample, longitudinal structure, monthly labor-force outcomes, and repeated panels—to study trends in women's birth-related career interruptions over time and across the education spectrum. Methodologically, I use event studies to compare women's monthly labor-force outcomes on the extensive and intensive margins from twenty-four months before to twenty-four months after births in the 1980s, 1990s, and 2000s. Rather than an abrupt change in opting out, I find that the pattern of birth-related interruptions has changed surprisingly little over the past thirty years—substantial and sustained interruptions remain common for mothers in all education categories. Rather than a revolution, I find an opt-out continuation.

  11. Using 2-Opt based evolution strategy for travelling salesman problem

    Directory of Open Access Journals (Sweden)

    Kenan Karagul

    2016-03-01

    Full Text Available Harmony search algorithm that matches the (µ+1 evolution strategy, is a heuristic method simulated by the process of music improvisation. In this paper, a harmony search algorithm is directly used for the travelling salesman problem. Instead of conventional selection operators such as roulette wheel, the transformation of real number values of harmony search algorithm to order index of vertex representation and improvement of solutions are obtained by using the 2-Opt local search algorithm. Then, the obtained algorithm is tested on two different parameter groups of TSPLIB. The proposed method is compared with classical 2-Opt which randomly started at each step and best known solutions of test instances from TSPLIB. It is seen that the proposed algorithm offers valuable solutions.

  12. Why persons choose to opt out of an exception from informed consent cardiac arrest trial.

    Science.gov (United States)

    Nelson, Maria J; Deiorio, Nicole M; Schmidt, Terri A; Zive, Dana M; Griffiths, Denise; Newgard, Craig D

    2013-06-01

    We sought to characterize persons who requested to opt out of an exception from informed consent (EFIC) cardiac arrest trial and their reasons for opting out. At one site of a multi-site, out-of-hospital, cardiac arrest EFIC trial (September 2007 - June 2009), persons who did not want to participate in the study could request an opt-out "NO STUDY" bracelet to prevent trial enrollment. We surveyed all persons who requested a bracelet by phone interview, web or mail. Opt-out bracelets were advertised in all public communication about the study, including community consultation and public disclosure efforts. Survey questions included demographics, Likert scale items about attitudes toward the trial and research in general, plus open-ended questions. We used descriptive statistics for standardized questions and qualitative analysis to identify common themes from open-ended questions. Sixty bracelets were requested by 50 individuals. Surveys were completed by 46 persons (92% response rate). Seventy percent of respondents agreed emergency research is important, but 87% objected to any research without consent. In the qualitative analysis, 5 overlapping themes emerged: questioning the ethics of EFIC research; concerns about how the study would impact end-of-life preferences; subjective emotions including sarcasm, anger, and allusions to past unethical research; negative reference to unrelated public health controversies; and objections to the study protocol based on misinformation. A primary reason for opting out from this EFIC trial was opposition to all research without informed consent, despite stated support for emergency research. Understanding the demographics and beliefs of persons opting out may aid researchers planning EFIC studies and help provide clarity in future EFIC-related community education efforts. Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.

  13. optBINS: Optimal Binning for histograms

    Science.gov (United States)

    Knuth, Kevin H.

    2018-03-01

    optBINS (optimal binning) determines the optimal number of bins in a uniform bin-width histogram by deriving the posterior probability for the number of bins in a piecewise-constant density model after assigning a multinomial likelihood and a non-informative prior. The maximum of the posterior probability occurs at a point where the prior probability and the the joint likelihood are balanced. The interplay between these opposing factors effectively implements Occam's razor by selecting the most simple model that best describes the data.

  14. Computed tomography device

    International Nuclear Information System (INIS)

    Ohhashi, A.

    1985-01-01

    A computed tomography device comprising a subtraction unit which obtains differential data strings representing the difference between each time-serial projection data string of a group of projection data strings corresponding to a prospective reconstruction image generated by projection data strings acquired by a data acquisition system, a convolution unit which convolves each time-serial projection data string of the group of projection data strings corresponding to the prospective reconstruction image, and a back-projection unit which back-projects the convolved data strings

  15. 12 CFR 571.27 - Renewal of opt-out.

    Science.gov (United States)

    2010-01-01

    ... period. Each opt-out renewal must be effective for a period of at least five years as provided in § 571... (ii) As part of a joint renewal notice from two or more members of an affiliated group of companies... provided by multiple companies with the ABC name or multiple companies in the ABC group or family of...

  16. Limited angle STIM and PIXE tomography of single cells

    International Nuclear Information System (INIS)

    Andrea, T.; Rothermel, M.; Werner, R.; Butz, T.; Reinert, T.

    2010-01-01

    STIM (scanning transmission ion microscopy) tomography has been shown to be a valuable method for the three-dimensional characterization of microsamples. It has, however, rarely been employed for the study of single cells, since a free-standing sample is needed for an ordinary tomography experiment. This requirement places high demands on sample preparation techniques. In this study cells fixated on a substrate rather than free-standing were used for tomography. Since the substrate prevented a full rotation of the sample an algorithm for limited-angle tomography was devised. STIM projections covering only a limited angular range of ca. 120 o were supplemented with simulated projections generated from a back and forth iteration between real space and Radon space. The energy loss caused by the substrate was subtracted from each projection. The cells were reconstructed using filtered backprojection. The surface of the cells as well as some interior structures could be reconstructed. Following the STIM projections a lesser number of PIXE (particle induced X-ray emission) projections were taken in order to obtain information about the elemental distribution of the sample. From the PIXE projections the three-dimensional phosphorus distribution within the cell was reconstructed using limited-angle tomography. Superimposition of the STIM and PIXE tomograms revealed the location of intracellular structures. Whereas STIM tomography is sensitive to density contrast, which are greatest at the surface, PIXE tomography is sensitive to changes in elemental concentration. Hence, the combination of the two methods can be very fruitful, while the limited angle approach can compensate some of the difficulties associated with tomography of single cells, namely preparation difficulties and excessive sample damage.

  17. Digital multilayer tomography

    International Nuclear Information System (INIS)

    Dueber, C.; Klose, K.J.; Thelen, M.

    1991-01-01

    With digital multilayer tomography a sequence of projection images is recorded by an image intensifier television system and stored as digital data during a linear run of a layer sequence. Using this data record, tomograms of the examined body region can be computed for any layer thickness by shifts and superimposition of the single projections later at a digital workstation. The qualities of digital and conventional tomograms are basically comparable. A drawback of digital tomography is its lower local resolution (512 x 512 image matrix), advantages are a lower radiation exposure, a shorter patient examination time, and the facilities of digital image processing (later processing, archive setup, transmission). (orig.) [de

  18. Single-photon emission computed tomography

    International Nuclear Information System (INIS)

    Budinger, T.F.

    1986-01-01

    Single photon tomography dates from the early 1960's when the idea of emission transverse section tomography was presented by Kuhl and Edwards. They used a rectilinear scanner and analogue back-projection methods to detect emissions from a series of sequential positions transverse to the cephaldcaudad axis of the body. This chapter presents an explanation of emission tomography by describing longitudinal and transverse section tomography. In principle all modes of tomography can be considered under the general topic of coded apertures wherein the code ranges from translation of a pinhole collimator to rotation of a parallel hole or focused collimator array

  19. OptFlux: an open-source software platform for in silico metabolic engineering.

    Science.gov (United States)

    Rocha, Isabel; Maia, Paulo; Evangelista, Pedro; Vilaça, Paulo; Soares, Simão; Pinto, José P; Nielsen, Jens; Patil, Kiran R; Ferreira, Eugénio C; Rocha, Miguel

    2010-04-19

    Over the last few years a number of methods have been proposed for the phenotype simulation of microorganisms under different environmental and genetic conditions. These have been used as the basis to support the discovery of successful genetic modifications of the microbial metabolism to address industrial goals. However, the use of these methods has been restricted to bioinformaticians or other expert researchers. The main aim of this work is, therefore, to provide a user-friendly computational tool for Metabolic Engineering applications. OptFlux is an open-source and modular software aimed at being the reference computational application in the field. It is the first tool to incorporate strain optimization tasks, i.e., the identification of Metabolic Engineering targets, using Evolutionary Algorithms/Simulated Annealing metaheuristics or the previously proposed OptKnock algorithm. It also allows the use of stoichiometric metabolic models for (i) phenotype simulation of both wild-type and mutant organisms, using the methods of Flux Balance Analysis, Minimization of Metabolic Adjustment or Regulatory on/off Minimization of Metabolic flux changes, (ii) Metabolic Flux Analysis, computing the admissible flux space given a set of measured fluxes, and (iii) pathway analysis through the calculation of Elementary Flux Modes. OptFlux also contemplates several methods for model simplification and other pre-processing operations aimed at reducing the search space for optimization algorithms. The software supports importing/exporting to several flat file formats and it is compatible with the SBML standard. OptFlux has a visualization module that allows the analysis of the model structure that is compatible with the layout information of Cell Designer, allowing the superimposition of simulation results with the model graph. The OptFlux software is freely available, together with documentation and other resources, thus bridging the gap from research in strain optimization

  20. X-ray phase radiography and tomography with grating interferometry and the reverse projection technique

    International Nuclear Information System (INIS)

    Wang, Zhili; Gao, Kun; Ge, Xin; Wu, Zhao; Chen, Heng; Wang, Shenghao; Wu, Ziyu; Zhu, Peiping; Yuan, Qingxi; Huang, Wanxia; Zhang, Kai

    2013-01-01

    X-ray grating interferometry provides substantially increased contrast over conventional absorption-based imaging methods, and therefore new and complementary information. Compared with other phase-contrast imaging techniques, x-ray grating interferometry can overcome some of the problems that have impaired the applications of x-ray phase-contrast radiography and phase tomography. Recently, special attention has been paid to the development of quantitative phase retrieval methods, which is mandatory to perform x-ray phase tomography, to achieve material identification, to differentiate distinct tissues, etc. Typically, the phase-stepping approach has been utilized for phase retrieval in grating interferometry. This method requires a grating scanning and acquisition of multiple radiographic projections, and therefore is disadvantageous in terms of imaging speed and radiation damage. Here we present an innovative, highly sensitive approach, dubbed ‘reverse projection’ (RP), for quantitative phase retrieval. Compared with the phase-stepping approach, the present RP method abandons grating scanning completely, and thus is advantageous due to its much higher efficiency and the reduced radiation dose, without the degradation of reconstruction quality. This review presents a detailed explanation of the principle of the RP method. Both radiography and phase tomography experiments are performed to validate the RP method. We believe that this new technique will find widespread applications in biomedical imaging and in vivo studies. (paper)

  1. 17 CFR 248.127 - Renewal of opt out elections.

    Science.gov (United States)

    2010-04-01

    ... (CONTINUED) REGULATIONS S-P AND S-AM Regulation S-AM: Limitations on Affiliate Marketing § 248.127 Renewal of... expires, you may not make marketing solicitations to a consumer who previously opted out, unless: (i) The....122(b). (3) Affiliates who may provide the notice. The notice required by this paragraph must be...

  2. 12 CFR 334.26 - Delivery of opt-out notices.

    Science.gov (United States)

    2010-01-01

    ... POLICY FAIR CREDIT REPORTING Affiliate Marketing § 334.26 Delivery of opt-out notices. (a) In general... the notice; or (4) Posts the notice on the Internet Web site at which the consumer obtained a product... notice; or (3) Posts the notice on an Internet Web site without requiring the consumer to acknowledge...

  3. 12 CFR 222.26 - Delivery of opt-out notices.

    Science.gov (United States)

    2010-01-01

    ... SYSTEM FAIR CREDIT REPORTING (REGULATION V) Affiliate Marketing § 222.26 Delivery of opt-out notices. (a... the affiliate providing the notice; or (4) Posts the notice on the Internet Web site at which the... affiliate providing the notice; or (3) Posts the notice on an Internet Web site without requiring the...

  4. 12 CFR 334.24 - Reasonable opportunity to opt out.

    Science.gov (United States)

    2010-01-01

    ...” to indicate their opt-out preference or that requires the consumer to check one of two blank check...) In general. You must not use eligibility information about a consumer that you receive from an affiliate to make a solicitation to the consumer about your products or services, unless the consumer is...

  5. Deemed consent: assessing the new opt-out approach to organ procurement in Wales.

    Science.gov (United States)

    Albertsen, Andreas

    2018-05-01

    In December 2015, Wales became the first country in the UK to move away from an opt-in system in organ procurement. The new legislation introduces the concept of deemed consent whereby a person who neither opt in nor opt out is deemed to have consented to donation. The data released by the National Health Service (NHS) in July 2017 provide an excellent opportunity to assess this legislation in light of concerns that it would decrease procurement rates for living and deceased donation, as well as sparking an increase in family refusals. None of these concerns have come to pass, with Wales experiencing more registered donors, fewer family refusals and more living donations. However, as the number of actual donors has dropped slightly from a high level, the situation must be monitored closely in the years to come. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  6. Wind farm design in complex terrain: the FarmOpt methodology

    DEFF Research Database (Denmark)

    Feng, Ju; Shen, Wen Zhong; Hansen, Kurt Schaldemose

    layout optimization algorithms. Various constraints are also modelled and considered in the design optimization problem for maximizing the annual energy production (AEP). A case study is presented to illustrate the effectiveness of the methodology. Further developments of the FarmOpt tool are also...

  7. A parallel 2-opt algorithm for the traveling salesman problem

    NARCIS (Netherlands)

    Verhoeven, M.G.A.; Aarts, E.H.L.; Swinkels, P.C.J.

    1995-01-01

    We present a scalable parallel local search algorithm based on data parallelism. The concept of distributed neighborhood structures is introduced, and applied to the Traveling Salesman Problem (TSP). Our parallel local search algorithm finds the same quality solutions as the classical 2-opt

  8. Inverse scattering theory foundations of tomography with diffracting wavefields

    International Nuclear Information System (INIS)

    Devaney, A.J.

    1987-01-01

    The underlying mathematical models employed in reflection and transmission computed tomography using diffracting wavefields (called diffraction tomography) are reviewed and shown to have a rigorous basis in inverse scattering theory. In transmission diffraction tomography the underlying wave model is shown to be the Rytov approximation to the complex phase of the wavefield transmitted by the object being probed while in reflection diffraction tomography the underlying wave model is shown to be the Born approximation to the backscattered wavefield from the object. In both cases the goal of the reconstruction process is the determination of the objects's complex index of refraction as a function of position r/sup →/ and, possibly, the frequency ω of the probing wavefield. By use of these approximations the reconstruction problem for both transmission and reflection diffraction tomography can be cast into the simple and elegant form of linearized inverse scattering theory. Linearized inverse scattering theory is shown to lead directly to generalized projection-slice theorems for both reflection and transmission diffraction tomography that provide a simple mathematical relationship between the object's complex index of refraction (the unknown) and the data (the complex phase of the transmitted wave or the complex amplitude of the reflected wave). The conventional projection-slice theorem of X-ray CT is shown to result from the generalized projection-slice theorem for transmission diffraction tomography in the limit of vanishing wavelength (in the absence of wave effects). Fourier based and back-projection type reconstruction algorithms are shown to be directly derivable from the generalized projection-slice theorems

  9. 12 CFR 717.24 - Reasonable opportunity to opt out.

    Science.gov (United States)

    2010-01-01

    ... completing a form that requires consumers to write a “yes” or “no” to indicate their opt-out preference or.... You must not use eligibility information about a consumer that you receive from an affiliate to make a solicitation to the consumer about your products or services, unless the consumer is provided a reasonable...

  10. 12 CFR 41.24 - Reasonable opportunity to opt out.

    Science.gov (United States)

    2010-01-01

    ... completing a form that requires consumers to write a “yes” or “no” to indicate their opt-out preference or... eligibility information about a consumer that it receives from an affiliate to make a solicitation to the consumer about the bank's products or services, unless the consumer is provided a reasonable opportunity to...

  11. Computer tomography of the neurocranium.

    Science.gov (United States)

    Liliequist, B; Forssell, A

    1976-07-01

    The experience with computer tomography of the neurocranium in 300 patients submitted for computer tomography of the brain is reported. The more appropriate projections which may be obtained with the second generation of scanners in combination with an elaborated reconstruction technique seem to constitute a replacement of conventional skull films.

  12. 12 CFR 222.22 - Scope and duration of opt-out.

    Science.gov (United States)

    2010-01-01

    ... SYSTEM FAIR CREDIT REPORTING (REGULATION V) Affiliate Marketing § 222.22 Scope and duration of opt-out.... (2) Continuing relationship—(i) In general. If the consumer establishes a continuing relationship... connection with— (A) A single continuing relationship or multiple continuing relationships that the consumer...

  13. MULTILEVEL ISCHEMIA IN DISORGANIZATION OF THE RETINAL INNER LAYERS ON PROJECTION-RESOLVED OPTICAL COHERENCE TOMOGRAPHY ANGIOGRAPHY.

    Science.gov (United States)

    Onishi, Alex C; Ashraf, Mohammed; Soetikno, Brian T; Fawzi, Amani A

    2018-04-10

    To examine the relationship between ischemia and disorganization of the retinal inner layers (DRIL). Cross-sectional retrospective study of 20 patients (22 eyes) with diabetic retinopathy presenting to a tertiary academic referral center, who had DRIL on structural optical coherence tomography (OCT) using Spectralis HRA + OCT (Heidelberg Engineering, Heidelberg, Germany) and OCT angiography with XR Avanti (Optovue Inc, Fremont, CA) on the same day. Optical coherence tomography angiography images were further processed to remove flow signal projection artifacts using a software algorithm adapted from recent studies. Retinal capillary perfusion in the superficial capillary plexuses, middle capillary plexuses, and deep capillary plexuses, as well as integrity of the photoreceptor lines on OCT was compared in areas with DRIL to control areas without DRIL in the same eye. Qualitative assessment of projection-resolved OCT angiography of eyes with DRIL on structural OCT demonstrated significant perfusion deficits compared with adjacent control areas (P < 0.001). Most lesions (85.7%) showed superimposed superficial capillary plexus and/or middle capillary plexus nonperfusion in addition to deep capillary plexus nonflow. Areas of DRIL were significantly associated with photoreceptor disruption (P = 0.035) compared with adjacent DRIL-free areas. We found that DRIL is associated with multilevel retinal capillary nonperfusion, suggesting an important role for ischemia in this OCT phenotype.

  14. Forum: Making Sense of the Opt-Out Movement: "Education Next" Talks with Scott Levy and Jonah Edelman

    Science.gov (United States)

    Levy, Scott; Edelman, Jonah

    2016-01-01

    Over the past few years, students by the thousands have refused to take their state's standardized tests. This "opt-out" phenomenon has prompted debate in state legislatures and in Washington, putting states at risk of losing Title I funds. Advocates describe opt-out as a grassroots movement of parents concerned about overtesting,…

  15. 16 CFR 680.24 - Reasonable opportunity to opt out.

    Science.gov (United States)

    2010-01-01

    ..., such as by posting the notice at an Internet Web site at which the consumer has obtained a product or... conducted on an Internet Web site. The consumer is required to decide, as a necessary part of proceeding... including in a privacy notice. The opt-out notice is included in a Gramm-Leach-Bliley Act privacy notice...

  16. 40 CFR Appendix A to Subpart III... - States With Approved State Implementation Plan Revisions Concerning CAIR SO2 Opt-In Units

    Science.gov (United States)

    2010-07-01

    ... Implementation Plan Revisions Concerning CAIR SO2 Opt-In Units A Appendix A to Subpart III of Part 97 Protection... BUDGET TRADING PROGRAM AND CAIR NOX AND SO2 TRADING PROGRAMS CAIR SO2 Opt-in Units Pt. 97, Subpt. III... Concerning CAIR SO2 Opt-In Units 1. The following States have State Implementation Plan revisions under § 51...

  17. Detailed Vascular Anatomy of the Human Retina by Projection-Resolved Optical Coherence Tomography Angiography

    Science.gov (United States)

    Campbell, J. P.; Zhang, M.; Hwang, T. S.; Bailey, S. T.; Wilson, D. J.; Jia, Y.; Huang, D.

    2017-02-01

    Optical coherence tomography angiography (OCTA) is a noninvasive method of 3D imaging of the retinal and choroidal circulations. However, vascular depth discrimination is limited by superficial vessels projecting flow signal artifact onto deeper layers. The projection-resolved (PR) OCTA algorithm improves depth resolution by removing projection artifact while retaining in-situ flow signal from real blood vessels in deeper layers. This novel technology allowed us to study the normal retinal vasculature in vivo with better depth resolution than previously possible. Our investigation in normal human volunteers revealed the presence of 2 to 4 distinct vascular plexuses in the retina, depending on location relative to the optic disc and fovea. The vascular pattern in these retinal plexuses and interconnecting layers are consistent with previous histologic studies. Based on these data, we propose an improved system of nomenclature and segmentation boundaries for detailed 3-dimensional retinal vascular anatomy by OCTA. This could serve as a basis for future investigation of both normal retinal anatomy, as well as vascular malformations, nonperfusion, and neovascularization.

  18. Project DEGRUPE: Goals and Historiographical Contextualization

    Directory of Open Access Journals (Sweden)

    COELHO, Maria Helena da Cruz

    2015-07-01

    Full Text Available This paper aims to present the main axes of the project DEGRUPE whose principal objective is to study the role of the clergy in the construction of the Iberian monarchies and mobility circuits designed by these protagonists. To fulfill this objective, the interuniversity project team of DEGRUPE opted for a comparative perspective between different kingdoms of the Iberian Peninsula. The second part of this paper consists of a brief analysis of the underlying historiographical framework of the project including mainly research on relationship between clergy and royalty in the middle ages.

  19. Optical Tomography in Combustion

    DEFF Research Database (Denmark)

    Evseev, Vadim

    spectral measurements at several line-of-sights with a view to applications for tomographic measurements on full-scale industrial combustion systems. The system was successfully applied on industrial scale for simultaneous fast exhaust gas temperature measurements in the three optical ports of the exhaust......D project, it was also important to investigate the spectral properties of major combustion species such as carbon dioxide and carbon monoxide in the infrared range at high temperatures to provide the theoretical background for the development of the optical tomography methods. The new software....... JQSRT 113 (2012) 2222, 10.1016/j.jqsrt.2012.07.015] included in the PhD thesis as an attachment. The knowledge and experience gained in the PhD project is the first important step towards introducing the advanced optical tomography methods of combustion diagnostics developed in the project to future...

  20. 12 CFR 222.21 - Affiliate marketing opt-out and exceptions.

    Science.gov (United States)

    2010-01-01

    ... solicitation for marketing purposes to a consumer with whom you have a pre-existing business relationship; (2... 12 Banks and Banking 3 2010-01-01 2010-01-01 false Affiliate marketing opt-out and exceptions. 222... FEDERAL RESERVE SYSTEM FAIR CREDIT REPORTING (REGULATION V) Affiliate Marketing § 222.21 Affiliate...

  1. 17 CFR 248.121 - Affiliate marketing opt out and exceptions.

    Science.gov (United States)

    2010-04-01

    ... business relationship with the consumer. (b) Making marketing solicitations—(1) In general. For purposes of... 17 Commodity and Securities Exchanges 3 2010-04-01 2010-04-01 false Affiliate marketing opt out... COMMISSION (CONTINUED) REGULATIONS S-P AND S-AM Regulation S-AM: Limitations on Affiliate Marketing § 248.121...

  2. Correction of computed tomography motion artifacts using pixel-specific back-projection

    International Nuclear Information System (INIS)

    Ritchie, C.J.; Crawford, C.R.; Godwin, J.D.; Kim, Y. King, K.F.

    1996-01-01

    Cardiac and respiratory motion can cause artifacts in computed tomography scans of the chest. The authors describe a new method for reducing these artifacts called pixel-specific back-projection (PSBP). PSBP reduces artifacts caused by in-plane motion by reconstructing each pixel in a frame of reference that moves with the in-plane motion in the volume being scanned. The motion of the frame of reference is specified by constructing maps that describe the motion of each pixel in the image at the time each projection was measured; these maps are based on measurements of the in-plane motion. PSBP has been tested in computer simulations and with volunteer data. In computer simulations, PSBP removed the structured artifacts caused by motion. In scans of two volunteers, PSBP reduced doubling and streaking in chest scans to a level that made the images clinically useful. PSBP corrections of liver scans were less satisfactory because the motion of the liver is predominantly superior-inferior (S-I). PSBP uses a unique set of motion parameters to describe the motion at each point in the chest as opposed to requiring that the motion be described by a single set of parameters. Therefore, PSBP may be more useful in correcting clinical scans than are other correction techniques previously described

  3. Wave Power Demonstration Project at Reedsport, Oregon

    Energy Technology Data Exchange (ETDEWEB)

    Mekhiche, Mike [Principal Investigator; Downie, Bruce [Project Manager

    2013-10-21

    Ocean wave power can be a significant source of large‐scale, renewable energy for the US electrical grid. The Electrical Power Research Institute (EPRI) conservatively estimated that 20% of all US electricity could be generated by wave energy. Ocean Power Technologies, Inc. (OPT), with funding from private sources and the US Navy, developed the PowerBuoy to generate renewable energy from the readily available power in ocean waves. OPT's PowerBuoy converts the energy in ocean waves to electricity using the rise and fall of waves to move the buoy up and down (mechanical stroking) which drives an electric generator. This electricity is then conditioned and transmitted ashore as high‐voltage power via underwater cable. OPT's wave power generation system includes sophisticated techniques to automatically tune the system for efficient conversion of random wave energy into low cost green electricity, for disconnecting the system in large waves for hardware safety and protection, and for automatically restoring operation when wave conditions normalize. As the first utility scale wave power project in the US, the Wave Power Demonstration Project at Reedsport, OR, will consist of 10 PowerBuoys located 2.5 miles off the coast. This U.S. Department of Energy Grant funding along with funding from PNGC Power, an Oregon‐based electric power cooperative, was utilized for the design completion, fabrication, assembly and factory testing of the first PowerBuoy for the Reedsport project. At this time, the design and fabrication of this first PowerBuoy and factory testing of the power take‐off subsystem are complete; additionally the power take‐off subsystem has been successfully integrated into the spar.

  4. Incomplete projection reconstruction of computed tomography based on the modified discrete algebraic reconstruction technique

    Science.gov (United States)

    Yang, Fuqiang; Zhang, Dinghua; Huang, Kuidong; Gao, Zongzhao; Yang, YaFei

    2018-02-01

    Based on the discrete algebraic reconstruction technique (DART), this study aims to address and test a new improved algorithm applied to incomplete projection data to generate a high quality reconstruction image by reducing the artifacts and noise in computed tomography. For the incomplete projections, an augmented Lagrangian based on compressed sensing is first used in the initial reconstruction for segmentation of the DART to get higher contrast graphics for boundary and non-boundary pixels. Then, the block matching 3D filtering operator was used to suppress the noise and to improve the gray distribution of the reconstructed image. Finally, simulation studies on the polychromatic spectrum were performed to test the performance of the new algorithm. Study results show a significant improvement in the signal-to-noise ratios (SNRs) and average gradients (AGs) of the images reconstructed from incomplete data. The SNRs and AGs of the new images reconstructed by DART-ALBM were on average 30%-40% and 10% higher than the images reconstructed by DART algorithms. Since the improved DART-ALBM algorithm has a better robustness to limited-view reconstruction, which not only makes the edge of the image clear but also makes the gray distribution of non-boundary pixels better, it has the potential to improve image quality from incomplete projections or sparse projections.

  5. Matlab enhanced multi-threaded tomography optimization sequence (MEMTOS)

    International Nuclear Information System (INIS)

    Lum, Edward S.; Pope, Chad L.

    2016-01-01

    Highlights: • Monte Carlo simulation of spent nuclear fuel assembly neutron computed tomography. • Optimized parallel calculations conducted from within the MATLAB environment. • Projection difference technique used to identify anomalies in spent nuclear fuel assemblies. - Abstract: One challenge associated with spent nuclear fuel assemblies is the lack of non-destructive analysis techniques to determine if fuel pins have been removed or replaced or if there are significant defects associated with fuel pins deep within a fuel assembly. Neutron computed tomography is a promising technique for addressing these qualitative issues. Monte Carlo simulation of spent nuclear fuel neutron computed tomography allows inexpensive process investigation and optimization. The main purpose of this work is to provide a fully automated advanced simulation framework for the analysis of spent nuclear fuel inspection using neutron computed tomography. The simulation framework, called Matlab Enhanced Multi-Threaded Tomography Optimization Sequence (MEMTOS) not only automates the simulation process, but also generates superior tomography image results. MEMTOS is written in the MATLAB scripting language and addresses file management, parallel Monte Carlo execution, results extraction, and tomography image generation. This paper describes the mathematical basis for neutron computed tomography, the Monte Carlo technique used to simulate neutron computed tomography, and the overall tomography simulation optimization algorithm. Sequence results presented include overall simulation speed enhancement, tomography and image results obtained for Experimental Breeder Reactor II spent fuel assemblies and light water reactor fuel assemblies. Optimization using a projection difference technique are also described.

  6. Electrical Impedance Tomography Technology

    Data.gov (United States)

    National Aeronautics and Space Administration — The goal for the Electrical Impedance Tomography Technology (EITT) project is to develop a reliable portable, lightweight device providing two-dimensional...

  7. Prediction of optimal deployment projection for transcatheter aortic valve replacement: angiographic 3-dimensional reconstruction of the aortic root versus multidetector computed tomography.

    OpenAIRE

    Binder Ronald K; Leipsic Jonathon; Wood David; Moore Teri; Toggweiler Stefan; Willson Alex; Gurvitch Ronen; Freeman Melanie; Webb John G

    2012-01-01

    BACKGROUND Identifying the optimal fluoroscopic projection of the aortic valve is important for successful transcatheter aortic valve replacement (TAVR). Various imaging modalities including multidetector computed tomography (MDCT) have been proposed for prediction of the optimal deployment projection. We evaluated a method that provides 3 dimensional angiographic reconstructions (3DA) of the aortic root for prediction of the optimal deployment angle and compared it with MDCT. METHODS AND RES...

  8. Doppler Tomography

    Science.gov (United States)

    Marsh, T. R.

    I review the method of Doppler tomography which translates binary-star line profiles taken at a series of orbital phases into a distribution of emission over the binary. I begin with a discussion of the basic principles behind Doppler tomography, including a comparison of the relative merits of maximum entropy regularisation versus filtered back-projection for implementing the inversion. Following this I discuss the issue of noise in Doppler images and possible methods for coping with it. Then I move on to look at the results of Doppler Tomography applied to cataclysmic variable stars. Outstanding successes to date are the discovery of two-arm spiral shocks in cataclysmic variable accretion discs and the probing of the stream/magnetospheric interaction in magnetic cataclysmic variable stars. Doppler tomography has also told us much about the stream/disc interaction in non-magnetic systems and the irradiation of the secondary star in all systems. The latter indirectly reveals such effects as shadowing by the accretion disc or stream. I discuss all of these and finish with some musings on possible future directions for the method. At the end I include a tabulation of Doppler maps published in refereed journals.

  9. Activity of OPT-80, a novel macrocycle, compared with those of eight other agents against selected anaerobic species.

    Science.gov (United States)

    Credito, Kim L; Appelbaum, Peter C

    2004-11-01

    Agar dilution MIC was used to compare activities of OPT-80, linezolid, vancomycin, teicoplanin, quinupristin/dalfopristin, amoxicillin/clavulanate, imipenem, clindamycin, and metronidazole against 350 gram-positive and -negative anaerobes. OPT-80 was active against gram-positive strains only, especially Clostridium spp. (85 strains tested, including 21 strains of C. difficile), with MICs ranging between

  10. Geometrical differences in target volumes based on 18F-fluorodeoxyglucose positron emission tomography/computed tomography and four-dimensional computed tomography maximum intensity projection images of primary thoracic esophageal cancer.

    Science.gov (United States)

    Guo, Y; Li, J; Wang, W; Zhang, Y; Wang, J; Duan, Y; Shang, D; Fu, Z

    2014-01-01

    The objective of the study was to compare geometrical differences of target volumes based on four-dimensional computed tomography (4DCT) maximum intensity projection (MIP) and 18F-fluorodeoxyglucose positron emission tomography/computed tomography (18F-FDG PET/CT) images of primary thoracic esophageal cancer for radiation treatment. Twenty-one patients with thoracic esophageal cancer sequentially underwent contrast-enhanced three-dimensional computed tomography (3DCT), 4DCT, and 18F-FDG PET/CT thoracic simulation scans during normal free breathing. The internal gross target volume defined as IGTVMIP was obtained by contouring on MIP images. The gross target volumes based on PET/CT images (GTVPET ) were determined with nine different standardized uptake value (SUV) thresholds and manual contouring: SUV≥2.0, 2.5, 3.0, 3.5 (SUVn); ≥20%, 25%, 30%, 35%, 40% of the maximum (percentages of SUVmax, SUVn%). The differences in volume ratio (VR), conformity index (CI), and degree of inclusion (DI) between IGTVMIP and GTVPET were investigated. The mean centroid distance between GTVPET and IGTVMIP ranged from 4.98 mm to 6.53 mm. The VR ranged from 0.37 to 1.34, being significantly (P<0.05) closest to 1 at SUV2.5 (0.94), SUV20% (1.07), or manual contouring (1.10). The mean CI ranged from 0.34 to 0.58, being significantly closest to 1 (P<0.05) at SUV2.0 (0.55), SUV2.5 (0.56), SUV20% (0.56), SUV25% (0.53), or manual contouring (0.58). The mean DI of GTVPET in IGTVMIP ranged from 0.61 to 0.91, and the mean DI of IGTVMIP in GTVPET ranged from 0.34 to 0.86. The SUV threshold setting of SUV2.5, SUV20% or manual contouring yields the best tumor VR and CI with internal-gross target volume contoured on MIP of 4DCT dataset, but 3DPET/CT and 4DCT MIP could not replace each other for motion encompassing target volume delineation for radiation treatment. © 2014 International Society for Diseases of the Esophagus.

  11. Use of a high density lead glass tubing projection chamber in positron emission tomography and in high energy physics

    International Nuclear Information System (INIS)

    Conti, M.; Guerra, A.D.; Habel, R.; Mulera, T.; Perez-Mendez, V.; Schwartz, G.

    1985-10-01

    We describe the principle of operation of a high density Projection Chamber, in which the converter/radiator and drift field shaping structures are combined in the form of high density (5 to 6 g/cm 3 ) lead glass tubing. The main applications of this type of detector to Medical Physics (Positron Emission Tomography) and High Energy Physics (Electromagnetic Calorimetry) are discussed

  12. OptMAVEn--a new framework for the de novo design of antibody variable region models targeting specific antigen epitopes.

    Directory of Open Access Journals (Sweden)

    Tong Li

    Full Text Available Antibody-based therapeutics provides novel and efficacious treatments for a number of diseases. Traditional experimental approaches for designing therapeutic antibodies rely on raising antibodies against a target antigen in an immunized animal or directed evolution of antibodies with low affinity for the desired antigen. However, these methods remain time consuming, cannot target a specific epitope and do not lead to broad design principles informing other studies. Computational design methods can overcome some of these limitations by using biophysics models to rationally select antibody parts that maximize affinity for a target antigen epitope. This has been addressed to some extend by OptCDR for the design of complementary determining regions. Here, we extend this earlier contribution by addressing the de novo design of a model of the entire antibody variable region against a given antigen epitope while safeguarding for immunogenicity (Optimal Method for Antibody Variable region Engineering, OptMAVEn. OptMAVEn simulates in silico the in vivo steps of antibody generation and evolution, and is capable of capturing the critical structural features responsible for affinity maturation of antibodies. In addition, a humanization procedure was developed and incorporated into OptMAVEn to minimize the potential immunogenicity of the designed antibody models. As case studies, OptMAVEn was applied to design models of neutralizing antibodies targeting influenza hemagglutinin and HIV gp120. For both HA and gp120, novel computational antibody models with numerous interactions with their target epitopes were generated. The observed rates of mutations and types of amino acid changes during in silico affinity maturation are consistent with what has been observed during in vivo affinity maturation. The results demonstrate that OptMAVEn can efficiently generate diverse computational antibody models with both optimized binding affinity to antigens and reduced

  13. Ethical issues surrounding the provider initiated opt--Out prenatal HIV screening practice in Sub-Saharan Africa: a literature review.

    Science.gov (United States)

    Bain, Luchuo Engelbert; Dierickx, Kris; Hens, Kristien

    2015-10-24

    Prevention of mother to child transmission of HIV remains a key public health priority in most developing countries. The provider Initiated Opt - Out Prenatal HIV Screening Approach, recommended by the World Health Organization (WHO) lately has been adopted and translated into policy in most Sub - Saharan African countries. To better ascertain the ethical reasons for or against the use of this approach, we carried out a literature review of the ethics literature. Papers published in English and French Languages between 1990 and 2015 from the following data bases were searched: Pubmed, Cochrane literature, Embase, Cinhal, Web of Science and Google Scholar. After screening from 302 identified relevant articles, 21 articles were retained for the critical review. Most authors considered this approach ethically justifiable due to its potential benefits to the mother, foetus and society (Beneficence). The breaching of respect for autonomy was considered acceptable on the grounds of libertarian paternalism. Most authors considered the Opt - Out approach to be less stigmatizing than the Opt - In. The main arguments against the Opt - Out approach were: non respect of patient autonomy, informed consent becoming a meaningless concept and the HIV test becoming compulsory, risk of losing trust in health care providers, neglect of social and psychological implications of doing an HIV test, risk of aggravation of stigma if all tested patients are not properly cared for and neglect of sociocultural peculiarities. The Opt - Out approach could be counterproductive in case gender sensitive issues within the various sociocultural representations are neglected, and actions to offer holistic care to all women who shall potentially test positive for HIV were not effectively ascertained. The Provider Initiated Opt - Out Prenatal HIV Screening option remains ethically acceptable, but deserves caution, active monitoring and evaluation within the translation of this approach into to practice.

  14. Improving image quality in Electrical Impedance Tomography (EIT using Projection Error Propagation-based Regularization (PEPR technique: A simulation study

    Directory of Open Access Journals (Sweden)

    Tushar Kanti Bera

    2011-03-01

    Full Text Available A Projection Error Propagation-based Regularization (PEPR method is proposed and the reconstructed image quality is improved in Electrical Impedance Tomography (EIT. A projection error is produced due to the misfit of the calculated and measured data in the reconstruction process. The variation of the projection error is integrated with response matrix in each iterations and the reconstruction is carried out in EIDORS. The PEPR method is studied with the simulated boundary data for different inhomogeneity geometries. Simulated results demonstrate that the PEPR technique improves image reconstruction precision in EIDORS and hence it can be successfully implemented to increase the reconstruction accuracy in EIT.>doi:10.5617/jeb.158 J Electr Bioimp, vol. 2, pp. 2-12, 2011

  15. Projection decomposition algorithm for dual-energy computed tomography via deep neural network.

    Science.gov (United States)

    Xu, Yifu; Yan, Bin; Chen, Jian; Zeng, Lei; Li, Lei

    2018-03-15

    Dual-energy computed tomography (DECT) has been widely used to improve identification of substances from different spectral information. Decomposition of the mixed test samples into two materials relies on a well-calibrated material decomposition function. This work aims to establish and validate a data-driven algorithm for estimation of the decomposition function. A deep neural network (DNN) consisting of two sub-nets is proposed to solve the projection decomposition problem. The compressing sub-net, substantially a stack auto-encoder (SAE), learns a compact representation of energy spectrum. The decomposing sub-net with a two-layer structure fits the nonlinear transform between energy projection and basic material thickness. The proposed DNN not only delivers image with lower standard deviation and higher quality in both simulated and real data, and also yields the best performance in cases mixed with photon noise. Moreover, DNN costs only 0.4 s to generate a decomposition solution of 360 × 512 size scale, which is about 200 times faster than the competing algorithms. The DNN model is applicable to the decomposition tasks with different dual energies. Experimental results demonstrated the strong function fitting ability of DNN. Thus, the Deep learning paradigm provides a promising approach to solve the nonlinear problem in DECT.

  16. 12 CFR 717.25 - Reasonable and simple methods of opting out.

    Science.gov (United States)

    2010-01-01

    ... simple methods for exercising an opt-out right do not include— (i) Requiring the consumer to write his or... out. (a) In general. You must not use eligibility information about a consumer that you receive from an affiliate to make a solicitation to the consumer about your products or services, unless the...

  17. Polynomial reconstruction of radial catalyst concentration distribution in an experimental type FCC riser for a low number of transversal projections in gamma ray tomography

    International Nuclear Information System (INIS)

    Melo, Silvio B.; Simoes, Francisco P.M.; Oliveira, Eric F. de; Santos, Maria das Gracas dos; Dantas, Carlos C.

    2007-01-01

    In the FCC - Fluid Catalytic Cracking process the Riser is an opaque cylinder, so that, in order to investigate the catalyst concentration inside, a gamma- ray based tomography is employed. Each section is submitted to a parallel beam and by means of the Beer-Lambert transmission is calculated. This tomography session is repeated from different angles, in manual tomographic experiments where the source/detector pair is rotated, producing in each direction what we called a transversal projection. In order to reconstruct the concentration of the present catalyst in a given moment some methods use successfully the inverse Radon transform through the filtered back-projection algorithm. The results are fully satisfactory for a large number of projections, widely seen as better than those produced by the algebraic methods. For a low number of projections, however, the algebraic methods become more competitive. In practice, simple experimental set-ups work with less than 10 projections, due to the time taken by the whole process. In this work, we present an investigation of polynomial reconstructions by using Bezier surfaces of arbitrary degree, adjusted to the experimental data through a least squares method. A computational algorithm was developed to implement the mathematical reconstruction for the 3D graphics presentation. (author)

  18. Optimization of Simulated Inventory Systems : OptQuest and Alternatives

    OpenAIRE

    Kleijnen, J.P.C.; Wan, J.

    2006-01-01

    This article illustrates simulation optimization through an (s, S) inventory manage- ment system. In this system, the goal function to be minimized is the expected value of speci…c inventory costs. Moreover, speci…c constraints must be satis…ed for some random simulation responses, namely the service or …ll rate, and for some determin- istic simulation inputs, namely the constraint s OptQuest method. The optimal...

  19. Efficacy and safety of fidaxomicin compared with oral vancomycin for the treatment of adults with Clostridium difficile-associated diarrhea: data from the OPT-80-003 and OPT-80-004 studies.

    Science.gov (United States)

    Chen, Luke F; Anderson, Deverick J

    2012-06-01

    Clostridium difficile is emerging as one of the most important and devastating pathogens affecting hospitalized populations around the world. The incidence of C. difficile infection is increasing and disease severity is worsening. Thus, an effective alternative to metronidazole and oral vancomycin is urgently needed. Two Phase III trials, OPT-80-003 and OPT-80-004, showed that oral fidaxomicin for 10 days was noninferior compared with treatment with oral vancomycin among adult patients with toxin-positive C. difficile-associated diarrhea (CDAD). Furthermore, fidaxomicin was associated with a lower rate of recurrence of CDAD within 4 weeks of completion of therapy. The safety and tolerability of fidaxomicin was consistent with earlier studies and established that fidaxomicin is an efficacious and well-tolerated treatment option for CDAD. Despite these potential advantages, the cost-effectiveness of this expensive agent remains poorly understood.

  20. The modification of hybrid method of ant colony optimization, particle swarm optimization and 3-OPT algorithm in traveling salesman problem

    Science.gov (United States)

    Hertono, G. F.; Ubadah; Handari, B. D.

    2018-03-01

    The traveling salesman problem (TSP) is a famous problem in finding the shortest tour to visit every vertex exactly once, except the first vertex, given a set of vertices. This paper discusses three modification methods to solve TSP by combining Ant Colony Optimization (ACO), Particle Swarm Optimization (PSO) and 3-Opt Algorithm. The ACO is used to find the solution of TSP, in which the PSO is implemented to find the best value of parameters α and β that are used in ACO.In order to reduce the total of tour length from the feasible solution obtained by ACO, then the 3-Opt will be used. In the first modification, the 3-Opt is used to reduce the total tour length from the feasible solutions obtained at each iteration, meanwhile, as the second modification, 3-Opt is used to reduce the total tour length from the entire solution obtained at every iteration. In the third modification, 3-Opt is used to reduce the total tour length from different solutions obtained at each iteration. Results are tested using 6 benchmark problems taken from TSPLIB by calculating the relative error to the best known solution as well as the running time. Among those modifications, only the second and third modification give satisfactory results except the second one needs more execution time compare to the third modifications.

  1. Acceptability of routine offer of HIV testing (opt-out approach) among ...

    African Journals Online (AJOL)

    Background: With the introduction of the opt out HIV testing policy in Ghana, the HIV test is offered routinely to all pregnant women unless they decline testing. Objective: To assess acceptability of the routine offer of HIV testing antenatal clinic (ANC) clients in the Wa municipality, Ghana. Design: Cross-sectional study of 270 ...

  2. 12 CFR 41.25 - Reasonable and simple methods of opting out.

    Science.gov (United States)

    2010-01-01

    ... exercising an opt-out right do not include— (i) Requiring the consumer to write his or her own letter; (ii.... A bank must not use eligibility information about a consumer that it receives from an affiliate to make a solicitation to the consumer about its products or services, unless the consumer is provided a...

  3. Feasibility study for mega-electron-volt electron beam tomography.

    Science.gov (United States)

    Hampel, U; Bärtling, Y; Hoppe, D; Kuksanov, N; Fadeev, S; Salimov, R

    2012-09-01

    Electron beam tomography is a promising imaging modality for the study of fast technical processes. But for many technical objects of interest x rays of several hundreds of keV energy are required to achieve sufficient material penetration. In this article we report on a feasibility study for fast electron beam computed tomography with a 1 MeV electron beam. The experimental setup comprises an electrostatic accelerator with beam optics, transmission target, and a single x-ray detector. We employed an inverse fan-beam tomography approach with radiographic projections being generated from the linearly moving x-ray source. Angular projections were obtained by rotating the object.

  4. Schedule evolution during the life-time of the LHC project

    CERN Document Server

    Foraz, K; Gaillard, H; Hauviller, Claude; Weisz, S

    2007-01-01

    The Large Hadron Collider Project was approved by the CERN Council in December 1994. The CERN management opted from the beginning of the project for a very aggressive installation planning based on a just-in-time sequencing of all activities. This paper aims to draw how different factors (technical development, procurement, logistics and organization) have impacted on the schedule evolution through the lifetime of the project. It describes the cause effect analysis of the major rescheduling that occurred during the installation of the LHC and presents some general conclusions potentially applicable in other projects.

  5. Extraction of optical scattering parameters and attenuation compensation in optical coherence tomography images of multi-layered tissue structures

    DEFF Research Database (Denmark)

    Thrane, Lars; Frosz, Michael Henoch; Tycho, Andreas

    2004-01-01

    A recently developed analytical optical coherence tomography (OCT) model [Thrane et al., J. Opt. Soc. Am. A 17, 484 (2000)] allows the extraction of optical scattering parameters from OCT images, thereby permitting attenuation compensation in those images. By expanding this theoretical model, we...... have developed a new method for extracting optical scattering parameters from multilayered tissue structures in vivo. To verify this, we used a Monte Carlo (MC) OCT model as a numerical phantom to simulate the OCT signal for het-erogeneous multilayered tissue. Excellent agreement between the extracted......, and the results hold promise for expanding the functional imaging capabilities of OCT....

  6. Physics and instrumentation of emission computed tomography

    International Nuclear Information System (INIS)

    Links, J.M.

    1986-01-01

    Transverse emission computed tomography can be divided into two distinct classes: single photon emission computed tomography (SPECT) and positron emission tomography (PET). SPECT is usually accomplished with specially-adapted scintillation cameras, although dedicated SPECT scanners are available. The special SPECT cameras are standard cameras which are mounted on gantries that allow 360 degree rotation around the long axis of the head or body. The camera stops at a number of angles around the body (usually 64-128), acquiring a ''projection'' image at each stop. The data from these projections are used to reconstruct transverse images with a standard ''filtered back-projection'' algorithm, identical to that used in transmission CT. Because the scintillation camera acquires two-dimensional images, a simple 360 degree rotation around the patient results in the acquisition of data for a number of contiguous transverse slices. These slices, once reconstructed, can be ''stacked'' in computer memory, and orthogonal coronal and sagittal slices produced. Additionally, reorienting algorithms allow the generation of slices that are oblique to the long axis of the body

  7. ODTbrain: a Python library for full-view, dense diffraction tomography.

    Science.gov (United States)

    Müller, Paul; Schürmann, Mirjam; Guck, Jochen

    2015-11-04

    Analyzing the three-dimensional (3D) refractive index distribution of a single cell makes it possible to describe and characterize its inner structure in a marker-free manner. A dense, full-view tomographic data set is a set of images of a cell acquired for multiple rotational positions, densely distributed from 0 to 360 degrees. The reconstruction is commonly realized by projection tomography, which is based on the inversion of the Radon transform. The reconstruction quality of projection tomography is greatly improved when first order scattering, which becomes relevant when the imaging wavelength is comparable to the characteristic object size, is taken into account. This advanced reconstruction technique is called diffraction tomography. While many implementations of projection tomography are available today, there is no publicly available implementation of diffraction tomography so far. We present a Python library that implements the backpropagation algorithm for diffraction tomography in 3D. By establishing benchmarks based on finite-difference time-domain (FDTD) simulations, we showcase the superiority of the backpropagation algorithm over the backprojection algorithm. Furthermore, we discuss how measurment parameters influence the reconstructed refractive index distribution and we also give insights into the applicability of diffraction tomography to biological cells. The present software library contains a robust implementation of the backpropagation algorithm. The algorithm is ideally suited for the application to biological cells. Furthermore, the implementation is a drop-in replacement for the classical backprojection algorithm and is made available to the large user community of the Python programming language.

  8. Positron emission tomography

    International Nuclear Information System (INIS)

    Pavuk, M.

    2003-12-01

    The aim of this project is to provide a simple summary of new trends in positron emission tomography and its basic physical principles. It provides thereby compendious introduction of the trends of the present development in diagnostics using PET systems. A review of available literature was performed. (author)

  9. The effect of including an opt-out option in discrete choice experiments

    NARCIS (Netherlands)

    J. Veldwijk (Jorien); M.S. Lambooij (Mattijs); E.W. de Bekker-Grob (Esther); H.A. Smit (Henriëtte); G.A. De Wit (G. Ardine)

    2014-01-01

    markdownabstractObjective: to determine to what extent the inclusion of an opt-out option in a DCE may have an effect on choice behaviour and therefore might influence the attribute level estimates, the relative importance of the attributes and calculated tradeoffs. Methods: 781 Dutch Type 2

  10. Industrial process gamma tomography. Final report of a coordinated research project 2003-2007

    International Nuclear Information System (INIS)

    2008-05-01

    Gamma computed tomography (CT) is complementary to radiotracer and gamma sealed source techniques largely used for analyzing industrial process units. Relevant target areas for gamma CT applications are generally known. Although the methodology is generic and applicable across broad industrial specimen and facilities, a number of specific items have been identified as the most appropriate target beneficiaries of these applications: distillation columns; packed beds; risers; fluidized beds and other multiphase processing units. These industrial process units present significant technical challenges to CT investigations in terms of the complexity of the multiphase flows that occur in them. In order to address these needs, the IAEA implemented a Coordinated Research Project (CRP) on Industrial Process Gamma Tomography with the overall objective of testing and validating CT techniques for diagnosing industrial multiphase processes. CT laboratories from Argentina, Brazil, Czech Republic, France, Republic of Korea, Malaysia, Norway, Poland, United Kingdom and the United States of America have participated. The specific objectives of the CRP were assessment of the tomographic methods, evaluation of them for investigation of multiphase engineering processes, and design of prototypes of simple CT systems for industrial processing, which can be transferred to other developing countries. The CRP has generated an active network, which also included other groups engaged in the CT field. The round robin test has played an important role in validation of techniques and software. This TECDOC is prepared based on the findings and achievements of the CRP. It is a comprehensive technical report containing valuable information, not readily available in any single publication elsewhere. The participants' reports and software developed by them are compiled in a CD-ROM and attached to the back cover. The guidelines and software packages described in this report can be used as an

  11. Cone beam tomography of the heart using single-photon emission-computed tomography

    International Nuclear Information System (INIS)

    Gullberg, G.T.; Christian, P.E.; Zeng, G.L.; Datz, F.L.; Morgan, H.T.

    1991-01-01

    The authors evaluated cone beam single-photon emission-computed tomography (SPECT) of the heart. A new cone beam reconstruction algorithm was used to reconstruct data collected from short scan acquisitions (of slightly more than 180 degrees) of a detector anteriorally traversing a noncircular orbit. The less than 360 degrees acquisition was used to minimize the attenuation artifacts that result from reconstructing posterior projections of 201T1 emissions from the heart. The algorithm includes a new method for reconstructing truncated projections of background tissue activity that eliminates reconstruction ring artifacts. Phantom and patient results are presented which compare a high-resolution cone beam collimator (50-cm focal length; 6.0-mm full width at half maximum [FWHM] at 10 cm) to a low-energy general purpose (LEGP) parallel hole collimator (8.2-mm FWHM at 10 cm) which is 1.33 times more sensitive. The cone beam tomographic results are free of reconstruction artifacts and show improved spatial and contrast resolution over that obtained with the LEGP parallel hole collimator. The limited angular sampling restrictions and truncation problems associated with cone beam tomography do not deter from obtaining diagnostic information. However, even though these preliminary results are encouraging, a thorough clinical study is still needed to investigate the specificity and sensitivity of cone beam tomography

  12. TVR-DART: A More Robust Algorithm for Discrete Tomography From Limited Projection Data With Automated Gray Value Estimation.

    Science.gov (United States)

    Xiaodong Zhuge; Palenstijn, Willem Jan; Batenburg, Kees Joost

    2016-01-01

    In this paper, we present a novel iterative reconstruction algorithm for discrete tomography (DT) named total variation regularized discrete algebraic reconstruction technique (TVR-DART) with automated gray value estimation. This algorithm is more robust and automated than the original DART algorithm, and is aimed at imaging of objects consisting of only a few different material compositions, each corresponding to a different gray value in the reconstruction. By exploiting two types of prior knowledge of the scanned object simultaneously, TVR-DART solves the discrete reconstruction problem within an optimization framework inspired by compressive sensing to steer the current reconstruction toward a solution with the specified number of discrete gray values. The gray values and the thresholds are estimated as the reconstruction improves through iterations. Extensive experiments from simulated data, experimental μCT, and electron tomography data sets show that TVR-DART is capable of providing more accurate reconstruction than existing algorithms under noisy conditions from a small number of projection images and/or from a small angular range. Furthermore, the new algorithm requires less effort on parameter tuning compared with the original DART algorithm. With TVR-DART, we aim to provide the tomography society with an easy-to-use and robust algorithm for DT.

  13. Images of gravitational and magnetic phenomena derived from two-dimensional back-projection Doppler tomography of interacting binary stars

    International Nuclear Information System (INIS)

    Richards, Mercedes T.; Cocking, Alexander S.; Fisher, John G.; Conover, Marshall J.

    2014-01-01

    We have used two-dimensional back-projection Doppler tomography as a tool to examine the influence of gravitational and magnetic phenomena in interacting binaries that undergo mass transfer from a magnetically active star onto a non-magnetic main-sequence star. This multitiered study of over 1300 time-resolved spectra of 13 Algol binaries involved calculations of the predicted dynamical behavior of the gravitational flow and the dynamics at the impact site, analysis of the velocity images constructed from tomography, and the influence on the tomograms of orbital inclination, systemic velocity, orbital coverage, and shadowing. The Hα tomograms revealed eight sources: chromospheric emission, a gas stream along the gravitational trajectory, a star-stream impact region, a bulge of absorption or emission around the mass-gaining star, a Keplerian accretion disk, an absorption zone associated with hotter gas, a disk-stream impact region, and a hot spot where the stream strikes the edge of a disk. We described several methods used to extract the physical properties of the emission sources directly from the velocity images, including S-wave analysis, the creation of simulated velocity tomograms from hydrodynamic simulations, and the use of synthetic spectra with tomography to sequentially extract the separate sources of emission from the velocity image. In summary, the tomography images have revealed results that cannot be explained solely by gravitational effects: chromospheric emission moving with the mass-losing star, a gas stream deflected from the gravitational trajectory, and alternating behavior between stream state and disk state. Our results demonstrate that magnetic effects cannot be ignored in these interacting binaries.

  14. An update in proton probe tomography

    Energy Technology Data Exchange (ETDEWEB)

    Sakellariou, A.; Cholewa, M.; Saint, A.; Legge, G.L.F. [Melbourne Univ., Parkville, VIC (Australia). School of Physics; Howard, J. [Australian National Univ., Canberra, ACT (Australia). Research School of Physical Sciences

    1996-12-31

    The analysis of scanning transmission ion microscopy (STIM) tomography data is improved. The volumetric density information is obtained directly from an iterative convolution and back-projection (BFP) reconstruction method. The iterative method allows the effects of stopping-power to be incorporated easily. One draw back is that a priori constituency information is required for the iterative method to work However, this is of no concern because the iterative method was designed with PIXE tomography in mind. In this light, the a priori information will be obtained as the zeroth iteration of a PIXE tomography iterative reconstruction method. 4 refs., 1 tab., 4 figs.

  15. An update in proton probe tomography

    Energy Technology Data Exchange (ETDEWEB)

    Sakellariou, A; Cholewa, M; Saint, A; Legge, G L.F. [Melbourne Univ., Parkville, VIC (Australia). School of Physics; Howard, J [Australian National Univ., Canberra, ACT (Australia). Research School of Physical Sciences

    1997-12-31

    The analysis of scanning transmission ion microscopy (STIM) tomography data is improved. The volumetric density information is obtained directly from an iterative convolution and back-projection (BFP) reconstruction method. The iterative method allows the effects of stopping-power to be incorporated easily. One draw back is that a priori constituency information is required for the iterative method to work However, this is of no concern because the iterative method was designed with PIXE tomography in mind. In this light, the a priori information will be obtained as the zeroth iteration of a PIXE tomography iterative reconstruction method. 4 refs., 1 tab., 4 figs.

  16. Fundamentals for routined utilization of tomography in beam diagnostic

    International Nuclear Information System (INIS)

    Reichau, Hermine

    2012-01-01

    A general and systematic approach to implement tomography for beam diagnostics has been invented and exemplarily shown for the invention of beam tomography for the Frankfurt Neutron Source. Following the diagnostic pipeline the first step was to prepare the data basis for the tomography reconstruction. For the monitoring, standard parameters have to be obtained with sufficient accuracy. In the context of this work, tomography has been kept as flexible as possible. Firstly, it will be used for the analysis of beam dynamics but also for the further development of beam tomography for routined utilization. Later on it will have to serve as a monitoring system at the end of the LEBT of FRANZ. The data preparation for tomography was demonstrated step by step. The iterated backprojection (FBP) algorithm was derived to show the basic idea of tomography which is contained in all forms of tomography algorithms. In connection with data exhibiting a high signal to noise ratio the FBP obtains the result with the highest accuracy, beyond that the accuracy can be controlled by the number of projections. The algebraic reconstruction and maximum entropy approach were outlined in a nutshell. By the introduction of the diagnostic pipeline in combination with the decision systematics the basis for a routined utilization of tomography in ion beam diagnostics have been established and exemplarily demonstrated on the introduction of beam tomography for FRANZ. A rotatable vacuum chamber has been developed to close a gap between the availability of projections to use the FBP and the small physical space on which they have to be determined. (orig.)

  17. 16 CFR 313.15 - Other exceptions to notice and opt out requirements.

    Science.gov (United States)

    2010-01-01

    ... consumer. (2) A consumer may revoke consent by subsequently exercising the right to opt out of future... ACTS OF CONGRESS PRIVACY OF CONSUMER FINANCIAL INFORMATION Exceptions § 313.15 Other exceptions to... at the direction of the consumer, provided that the consumer has not revoked the consent or direction...

  18. Basic methodology of tomographic imaging by filtered inverse projection at a turbo-pump. Project report; Methodische Grundlagen fuer die Tomographie durch gefilterte Rueckprojektion an einer Axialpumpe. Projektbericht

    Energy Technology Data Exchange (ETDEWEB)

    Hoppe, D.

    2000-11-01

    A two-phase medium consisting of a fluid containing gas is transported in a turbo-pump via an impeller. The interaction between the gaseous phase and the impeller is to be examined by tomography with gamma rays. Reconstruction of the image of the object is to be made by way of filtered inverse projection. The methodology of using this principle in the given system (geometry and measuring conditions) is explained. (orig./CB) [German] Ein zweiphasiges, aus einer gashaltigen Fluessigkeit bestehendes Medium wird in einer Axialpumpe von einem propellerartigen Laufrad senkrecht zur Drehachse dieses Laufrades transportiert. Die Wechselwirkung zwischen der Gasphase und dem Laufrad soll unter Verwendung von Gamma-Strahlung mittels Tomographie untersucht werden. Dabei ist fuer die Rekonstruktion des Objektbildes das Prinzip der sogenannten gefilterten Rueckprojektion vorgesehen. Die methodischen Grundlagen fuer die Nutzung dieses Prinzips unter von vorgesehenen geometrischen und messtechnischen Bedingungen sind Gegenstand dieser Arbeit. (orig.)

  19. An electron tomography algorithm for reconstructing 3D morphology using surface tangents of projected scattering interfaces

    Science.gov (United States)

    Petersen, T. C.; Ringer, S. P.

    2010-03-01

    Upon discerning the mere shape of an imaged object, as portrayed by projected perimeters, the full three-dimensional scattering density may not be of particular interest. In this situation considerable simplifications to the reconstruction problem are possible, allowing calculations based upon geometric principles. Here we describe and provide an algorithm which reconstructs the three-dimensional morphology of specimens from tilt series of images for application to electron tomography. Our algorithm uses a differential approach to infer the intersection of projected tangent lines with surfaces which define boundaries between regions of different scattering densities within and around the perimeters of specimens. Details of the algorithm implementation are given and explained using reconstruction calculations from simulations, which are built into the code. An experimental application of the algorithm to a nano-sized Aluminium tip is also presented to demonstrate practical analysis for a real specimen. Program summaryProgram title: STOMO version 1.0 Catalogue identifier: AEFS_v1_0 Program summary URL:http://cpc.cs.qub.ac.uk/summaries/AEFS_v1_0.html Program obtainable from: CPC Program Library, Queen's University, Belfast, N. Ireland Licensing provisions: Standard CPC licence, http://cpc.cs.qub.ac.uk/licence/licence.html No. of lines in distributed program, including test data, etc.: 2988 No. of bytes in distributed program, including test data, etc.: 191 605 Distribution format: tar.gz Programming language: C/C++ Computer: PC Operating system: Windows XP RAM: Depends upon the size of experimental data as input, ranging from 200 Mb to 1.5 Gb Supplementary material: Sample output files, for the test run provided, are available. Classification: 7.4, 14 External routines: Dev-C++ ( http://www.bloodshed.net/devcpp.html) Nature of problem: Electron tomography of specimens for which conventional back projection may fail and/or data for which there is a limited angular

  20. 12 CFR 216.15 - Other exceptions to notice and opt out requirements.

    Science.gov (United States)

    2010-01-01

    ... insurance to the consumer. (2) A consumer may revoke consent by subsequently exercising the right to opt out... RESERVE SYSTEM PRIVACY OF CONSUMER FINANCIAL INFORMATION (REGULATION P) Exceptions § 216.15 Other... consent or at the direction of the consumer, provided that the consumer has not revoked the consent or...

  1. 12 CFR 332.15 - Other exceptions to notice and opt out requirements.

    Science.gov (United States)

    2010-01-01

    ... insurance to the consumer. (2) A consumer may revoke consent by subsequently exercising the right to opt out... STATEMENTS OF GENERAL POLICY PRIVACY OF CONSUMER FINANCIAL INFORMATION Exceptions § 332.15 Other exceptions... consent or at the direction of the consumer, provided that the consumer has not revoked the consent or...

  2. The kids at Hamilton Elementary School: Purposes and practices for co-opting science

    Science.gov (United States)

    Ortiz, Loaiza

    The purpose of this study was to explore youth's purposes and motivations for engaging in science through the lens of science practices. The construct of science practices allowed me to see science in youths' lives in a holistic way, shaped by social, political, historical, economic and cultural forces. The framework for understanding urban youths' science practices is grounded in the intersections of critical and feminist theory, sociocultural learning theories, especially as applied in research in urban science education, and recent work in critical literacy studies. As I explored the answers to my research questions---(1) When 5th grade youth, living in predominantly Latino communities struggling with urban poverty, engage in science how and why do they co-opt science in ways that result in changes in participation in science? (2) What are the science practices that facilitate youths' coopting of science? And how are those practices framed by context (school, out-of-school), content (LiFE curriculum), and funds of knowledge? (3) In what ways are science practices expressions of youths' scientific literacy? And (4) In what ways do youth use science practices as tools for expressing identities and agency?---I engaged in feminist ethnography with embedded case studies. Data were collected in 2004 in school and in out of school settings. I recorded numerous informal conversations, interviews, and observations both during after-school and students' regular science and non-science classes. Findings describe how and why students co-opted science for purposes that make sense for their lives. These purposes included gaining and activating resources, building and maintaining social relationships, bridging home and school knowledge, positioning themselves with authority, and constructing science identities. Findings also explored what practices facilitated youth's co-opting of science. I highlighted three practices: making ideas public, storytelling and prioritizing and

  3. Vinayaka : A Semi-Supervised Projected Clustering Method Using Differential Evolution

    OpenAIRE

    Satish Gajawada; Durga Toshniwal

    2012-01-01

    Differential Evolution (DE) is an algorithm for evolutionary optimization. Clustering problems have beensolved by using DE based clustering methods but these methods may fail to find clusters hidden insubspaces of high dimensional datasets. Subspace and projected clustering methods have been proposed inliterature to find subspace clusters that are present in subspaces of dataset. In this paper we proposeVINAYAKA, a semi-supervised projected clustering method based on DE. In this method DE opt...

  4. Comparison of Volumes between Four-Dimensional Computed Tomography and Cone-Beam Computed Tomography Images using Dynamic Phantom

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Seong Eun; Won, Hui Su; Hong, Joo Wan; Chang, Nam Jun; Jung, Woo Hyun; Choi, Byeong Don [Dept. of Radiation Oncology, Seoul National University Bundang Hospital, Sungnam (Korea, Republic of)

    2016-12-15

    The aim of this study was to compare the differences between the volumes acquired with four-dimensional computed tomography (4DCT)images with a reconstruction image-filtering algorithm and cone-beam computed tomography (CBCT) images with dynamic phantom. The 4DCT images were obtained from the computerized imaging reference systems (CIRS) phantom using a computed tomography (CT) simulator. We analyzed the volumes for maximum intensity projection (MIP), minimum intensity projection (MinIP) and average intensity projection (AVG) of the images obtained with the 4DCT scanner against those acquired from CBCT images with CT ranger tools. Difference in volume for node of 1, 2 and 3 cm between CBCT and 4DCT was 0.54⁓2.33, 5.16⁓8.06, 9.03⁓20.11 ml in MIP, respectively, 0.00⁓1.48, 0.00⁓8.47, 1.42⁓24.85 ml in MinIP, respectively and 0.00⁓1.17, 0.00⁓2.19, 0.04⁓3.35 ml in AVG, respectively. After a comparative analysis of the volumes for each nodal size, it was apparent that the CBCT images were similar to the AVG images acquired using 4DCT.

  5. Can a Repeated Opt-Out Reminder mitigate hypothetical bias in discrete choice experiments?

    DEFF Research Database (Denmark)

    Alemu, Mohammed Hussen; Olsen, Søren Bøye

    2018-01-01

    In this paper, we test whether a Repeated Opt-Out Reminder (ROOR) can mitigate hypothetical bias in stated discrete choice experiments (DCE). The data originate from a field experiment concerning consumer preferences for a novel food product made from cricket flour. Utilising a between...

  6. X-ray Compton line scan tomography

    Energy Technology Data Exchange (ETDEWEB)

    Kupsch, Andreas; Lange, Axel; Jaenisch, Gerd-Ruediger [Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin (Germany). Fachgruppe 8.5 - Mikro-ZfP; Hentschel, Manfred P. [Technische Univ. Berlin (Germany); Kardjilov, Nikolay; Markoetter, Henning; Hilger, Andre; Manke, Ingo [Helmholtz-Zentrum Berlin (HZB) (Germany); Toetzke, Christian [Potsdam Univ. (Germany)

    2015-07-01

    The potentials of incoherent X-ray scattering (Compton) computed tomography (CT) are investigated. The imaging of materials of very different atomic number or density at once is generally a perpetual challenge for X-ray tomography or radiography. In a basic laboratory set-up for simultaneous perpendicular Compton scattering and direct beam attenuation tomography are conducted by single channel photon counting line scans. This results in asymmetric distortions of the projection profiles of the scattering CT data set. In a first approach, corrections of Compton scattering data by taking advantage of rotational symmetry yield tomograms without major geometric artefacts. A cylindrical sample composed of PE, PA, PVC, glass and wood demonstrates similar Compton contrast for all the substances, while the conventional absorption tomogram only reveals the two high order materials. Comparison to neutron tomography reveals astonishing similarities except for the glass component (without hydrogen). Therefore, Compton CT offers the potential to replace neutron tomography, which requires much more efforts.

  7. Optimization of the Geometric Beta for the SSR2 Cavities of the Project X

    International Nuclear Information System (INIS)

    Solyak, N.; Vostrikov, A.; Yakovlev, V.P.; Awida, M.H.; Berrutti, P.; Gonin, I.V.

    2012-01-01

    Project X based on the 3 GeV CW superconducting Linac and is currently in the R and D phase. The CW SC Linac starts from a low-energy SCRF section (2.1 - 165 MeV) containing three different types of resonators. HWR f = 162.5 MHz (2.1 - 11 MeV) having beta= 0.11, SSR1 f = 325 MHz (11 - 35 MeV) having beta = 0.21. In this paper we present the analysis that lead to the final design of SSR2 f = 325 MHz cavity (35 - 165 MeV). We present the results of optimization of the geometric beta and the comparison between single, double and triple spoke resonators used in Project X frontend. A β optimization has been carried out for the last spoke cavity section of Project X front end. The optimization process of β opt for a single spoke resonator family SSR2 shown that β opt = 0.47 looks better than the previous choice, which is β opt = 0.4. This change can save some cavities and provide the same final energy for this section, 160 MeV. Single double and triple spoke resonator performances have been compared. The best option is the single spoke resonator SSR2 because the NTTF of a multi-spoke resonator is much narrower than a single one. In the energy range considered (40-160 MeV) the most efficient resonator is the single spoke one.

  8. k-OptForce: integrating kinetics with flux balance analysis for strain design.

    Directory of Open Access Journals (Sweden)

    Anupam Chowdhury

    2014-02-01

    Full Text Available Computational strain design protocols aim at the system-wide identification of intervention strategies for the enhanced production of biochemicals in microorganisms. Existing approaches relying solely on stoichiometry and rudimentary constraint-based regulation overlook the effects of metabolite concentrations and substrate-level enzyme regulation while identifying metabolic interventions. In this paper, we introduce k-OptForce, which integrates the available kinetic descriptions of metabolic steps with stoichiometric models to sharpen the prediction of intervention strategies for improving the bio-production of a chemical of interest. It enables identification of a minimal set of interventions comprised of both enzymatic parameter changes (for reactions with available kinetics and reaction flux changes (for reactions with only stoichiometric information. Application of k-OptForce to the overproduction of L-serine in E. coli and triacetic acid lactone (TAL in S. cerevisiae revealed that the identified interventions tend to cause less dramatic rearrangements of the flux distribution so as not to violate concentration bounds. In some cases the incorporation of kinetic information leads to the need for additional interventions as kinetic expressions render stoichiometry-only derived interventions infeasible by violating concentration bounds, whereas in other cases the kinetic expressions impart flux changes that favor the overproduction of the target product thereby requiring fewer direct interventions. A sensitivity analysis on metabolite concentrations shows that the required number of interventions can be significantly affected by changing the imposed bounds on metabolite concentrations. Furthermore, k-OptForce was capable of finding non-intuitive interventions aiming at alleviating the substrate-level inhibition of key enzymes in order to enhance the flux towards the product of interest, which cannot be captured by stoichiometry-alone analysis

  9. Client’s flexibility in renovation projects with long-term DBFMO contracts

    NARCIS (Netherlands)

    Kuhlmann, M.; Blokhuis, E.G.J.; Han, Q.; Schaefer, W.F.; Yildiz, H.T.

    2009-01-01

    Construction project clients are faced with long-term commitments when opting for a DBFMO contract, the Dutch version of PFI. This way of contracting is characterized by the delivery of a full housing service to the client over a period of decades, offered by a construction consortium including

  10. X-ray Computed Tomography.

    Science.gov (United States)

    Michael, Greg

    2001-01-01

    Describes computed tomography (CT), a medical imaging technique that produces images of transaxial planes through the human body. A CT image is reconstructed mathematically from a large number of one-dimensional projections of a plane. The technique is used in radiological examinations and radiotherapy treatment planning. (Author/MM)

  11. 16 CFR 680.23 - Contents of opt-out notice; consolidated and equivalent notices.

    Science.gov (United States)

    2010-01-01

    ... equivalent notices. 680.23 Section 680.23 Commercial Practices FEDERAL TRADE COMMISSION THE FAIR CREDIT REPORTING ACT AFFILIATE MARKETING § 680.23 Contents of opt-out notice; consolidated and equivalent notices... receiving marketing than is required by this part, the requirements of this section may be satisfied by...

  12. 12 CFR 717.23 - Contents of opt-out notice; consolidated and equivalent notices.

    Science.gov (United States)

    2010-01-01

    ... AFFECTING CREDIT UNIONS FAIR CREDIT REPORTING Affiliate Marketing § 717.23 Contents of opt-out notice..., conspicuous, and concise, and must accurately disclose: (i) The name of the affiliate(s) providing the notice. If the notice is provided jointly by multiple affiliates and each affiliate shares a common name...

  13. 4D Electron Tomography

    Science.gov (United States)

    Kwon, Oh-Hoon; Zewail, Ahmed H.

    2010-06-01

    Electron tomography provides three-dimensional (3D) imaging of noncrystalline and crystalline equilibrium structures, as well as elemental volume composition, of materials and biological specimens, including those of viruses and cells. We report the development of 4D electron tomography by integrating the fourth dimension (time resolution) with the 3D spatial resolution obtained from a complete tilt series of 2D projections of an object. The different time frames of tomograms constitute a movie of the object in motion, thus enabling studies of nonequilibrium structures and transient processes. The method was demonstrated using carbon nanotubes of a bracelet-like ring structure for which 4D tomograms display different modes of motion, such as breathing and wiggling, with resonance frequencies up to 30 megahertz. Applications can now make use of the full space-time range with the nanometer-femtosecond resolution of ultrafast electron tomography.

  14. Opting out of an ever closer union

    DEFF Research Database (Denmark)

    Adler-Nissen, Rebecca

    2011-01-01

    How is sovereignty managed in the EU? This paper investigates the relationship between sovereignty and European integration through the prism of national opt-outs from EU treaties, addressing an apparent contradiction in contemporary European governance: the contrasting processes of integration...... and differentiation. On the one hand, European integration is increasing as states transfer sovereign competencies to the EU. On the other hand, we see a multitude of differentiation processes through which member states choose to disengage from the EU polity by negotiating exemptions or derogations. Drawing...... on Pierre Bourdieu’s political sociology, the paper argues that to understand how sovereignty is exercised and interpreted in the EU, it is necessary to focus not only on the constitutive and regulative dimensions of sovereignty, but equally on the practice dimension. This entails an exploration of how...

  15. Opt-out of Voluntary HIV Testing: A Singapore Hospital's Experience

    OpenAIRE

    Chua, Arlene C.; Leo, Yee Sin; Cavailler, Philippe; Chu, Christine; Ng, Aloysius; Ng, Oon Tek; Krishnan, Prabha

    2012-01-01

    INTRODUCTION: Since 2008, the Singapore Ministry of Health (MOH) has expanded HIV testing by increasing anonymous HIV test sites, as well as issuing a directive to hospitals to offer routine voluntary opt out inpatient HIV testing. We reviewed this program implemented at the end of 2008 at Tan Tock Seng Hospital (TTSH), the second largest acute care general hospital in Singapore. METHODS AND FINDINGS: From January 2009 to December 2010, all inpatients aged greater or equal than 21 years were ...

  16. 12 CFR 571.23 - Contents of opt-out notice; consolidated and equivalent notices.

    Science.gov (United States)

    2010-01-01

    ... TREASURY FAIR CREDIT REPORTING Affiliate Marketing § 571.23 Contents of opt-out notice; consolidated and... concise, and must accurately disclose: (i) The name of the affiliate(s) providing the notice. If the notice is provided jointly by multiple affiliates and each affiliate shares a common name, such as “ABC...

  17. The gastropod shell has been co-opted to kill parasitic nematodes.

    Science.gov (United States)

    Rae, R

    2017-07-06

    Exoskeletons have evolved 18 times independently over 550 MYA and are essential for the success of the Gastropoda. The gastropod shell shows a vast array of different sizes, shapes and structures, and is made of conchiolin and calcium carbonate, which provides protection from predators and extreme environmental conditions. Here, I report that the gastropod shell has another function and has been co-opted as a defense system to encase and kill parasitic nematodes. Upon infection, cells on the inner layer of the shell adhere to the nematode cuticle, swarm over its body and fuse it to the inside of the shell. Shells of wild Cepaea nemoralis, C. hortensis and Cornu aspersum from around the U.K. are heavily infected with several nematode species including Caenorhabditis elegans. By examining conchology collections I show that nematodes are permanently fixed in shells for hundreds of years and that nematode encapsulation is a pleisomorphic trait, prevalent in both the achatinoid and non-achatinoid clades of the Stylommatophora (and slugs and shelled slugs), which diverged 90-130 MYA. Taken together, these results show that the shell also evolved to kill parasitic nematodes and this is the only example of an exoskeleton that has been co-opted as an immune system.

  18. Development of emission computed tomography in Japan

    International Nuclear Information System (INIS)

    Tanaka, E.

    1984-01-01

    Two positron emission computed tomography (PCT) devices developed in Japan are described. One is for head and the other for wholebody. The devices show fairly quantitative images with slight modifications of the existing algorithms because they were developed based on filtered back-projection. The PCT device seems to be better than the single photon emission computed tomography (SPECT) since it provides adequade compensation for photon attenuation in patients. (M.A.C.) [pt

  19. Industrial Computed Tomography using Proximal Algorithm

    KAUST Repository

    Zang, Guangming

    2016-01-01

    fewer projections. We compare our framework to state-of-the-art methods and existing popular software tomography reconstruction packages, on both synthetic and real datasets, and show superior reconstruction quality, especially from noisy data and a

  20. Geometric reconstruction methods for electron tomography

    Energy Technology Data Exchange (ETDEWEB)

    Alpers, Andreas, E-mail: alpers@ma.tum.de [Zentrum Mathematik, Technische Universität München, D-85747 Garching bei München (Germany); Gardner, Richard J., E-mail: Richard.Gardner@wwu.edu [Department of Mathematics, Western Washington University, Bellingham, WA 98225-9063 (United States); König, Stefan, E-mail: koenig@ma.tum.de [Zentrum Mathematik, Technische Universität München, D-85747 Garching bei München (Germany); Pennington, Robert S., E-mail: robert.pennington@uni-ulm.de [Center for Electron Nanoscopy, Technical University of Denmark, DK-2800 Kongens Lyngby (Denmark); Boothroyd, Chris B., E-mail: ChrisBoothroyd@cantab.net [Ernst Ruska-Centre for Microscopy and Spectroscopy with Electrons and Peter Grünberg Institute, Forschungszentrum Jülich, D-52425 Jülich (Germany); Houben, Lothar, E-mail: l.houben@fz-juelich.de [Ernst Ruska-Centre for Microscopy and Spectroscopy with Electrons and Peter Grünberg Institute, Forschungszentrum Jülich, D-52425 Jülich (Germany); Dunin-Borkowski, Rafal E., E-mail: rdb@fz-juelich.de [Ernst Ruska-Centre for Microscopy and Spectroscopy with Electrons and Peter Grünberg Institute, Forschungszentrum Jülich, D-52425 Jülich (Germany); Joost Batenburg, Kees, E-mail: Joost.Batenburg@cwi.nl [Centrum Wiskunde and Informatica, NL-1098XG, Amsterdam, The Netherlands and Vision Lab, Department of Physics, University of Antwerp, B-2610 Wilrijk (Belgium)

    2013-05-15

    Electron tomography is becoming an increasingly important tool in materials science for studying the three-dimensional morphologies and chemical compositions of nanostructures. The image quality obtained by many current algorithms is seriously affected by the problems of missing wedge artefacts and non-linear projection intensities due to diffraction effects. The former refers to the fact that data cannot be acquired over the full 180° tilt range; the latter implies that for some orientations, crystalline structures can show strong contrast changes. To overcome these problems we introduce and discuss several algorithms from the mathematical fields of geometric and discrete tomography. The algorithms incorporate geometric prior knowledge (mainly convexity and homogeneity), which also in principle considerably reduces the number of tilt angles required. Results are discussed for the reconstruction of an InAs nanowire. - Highlights: ► Four algorithms for electron tomography are introduced that utilize prior knowledge. ► Objects are assumed to be homogeneous; convexity and regularity is also discussed. ► We are able to reconstruct slices of a nanowire from as few as four projections. ► Algorithms should be selected based on the specific reconstruction task at hand.

  1. Geometric reconstruction methods for electron tomography

    International Nuclear Information System (INIS)

    Alpers, Andreas; Gardner, Richard J.; König, Stefan; Pennington, Robert S.; Boothroyd, Chris B.; Houben, Lothar; Dunin-Borkowski, Rafal E.; Joost Batenburg, Kees

    2013-01-01

    Electron tomography is becoming an increasingly important tool in materials science for studying the three-dimensional morphologies and chemical compositions of nanostructures. The image quality obtained by many current algorithms is seriously affected by the problems of missing wedge artefacts and non-linear projection intensities due to diffraction effects. The former refers to the fact that data cannot be acquired over the full 180° tilt range; the latter implies that for some orientations, crystalline structures can show strong contrast changes. To overcome these problems we introduce and discuss several algorithms from the mathematical fields of geometric and discrete tomography. The algorithms incorporate geometric prior knowledge (mainly convexity and homogeneity), which also in principle considerably reduces the number of tilt angles required. Results are discussed for the reconstruction of an InAs nanowire. - Highlights: ► Four algorithms for electron tomography are introduced that utilize prior knowledge. ► Objects are assumed to be homogeneous; convexity and regularity is also discussed. ► We are able to reconstruct slices of a nanowire from as few as four projections. ► Algorithms should be selected based on the specific reconstruction task at hand

  2. TH-E-17A-05: Optimizing Four Dimensional Cone Beam Computed Tomography Projection Allocation to Respiratory Bins

    International Nuclear Information System (INIS)

    OBrien, R; Shieh, C; Kipritidis, J; Keall, P

    2014-01-01

    Purpose: Four dimensional cone beam computed tomography (4DCBCT) is an emerging image guidance strategy but it can suffer from poor image quality. To avoid repeating scans it is beneficial to make the best use of the imaging data obtained. For conventional 4DCBCT the location and size of respiratory bins is fixed and projections are allocated to the respiratory bin within which it falls. Strictly adhering to this rule is unnecessary and can compromise image quality. In this study we optimize the size and location of respiratory bins and allow projections to be sourced from adjacent phases of the respiratory cycle. Methods: A mathematical optimization framework using mixed integer quadratic programming has been developed that determines when to source projections from adjacent respiratory bins and optimizes the size and location of the bins. The method, which we will call projection sharing, runs in under 2 seconds of CPU time. Five 4DCBCT datasets of stage III-IV lung cancer patients were used to test the algorithm. The standard deviation of the angular separation between projections (SD-A) and the standard deviation in the volume of the reconstructed fiducial gold coil (SD-V) were used as proxies to measure streaking artefacts and motion blur respectively. Results: The SD-A using displacement binning and projection sharing was 30%–50% smaller than conventional phase based binning and 59%–76% smaller than conventional displacement binning indicating more uniformly spaced projections and fewer streaking artefacts. The SD-V was 20–90% smaller when using projection sharing than using conventional phase based binning suggesting more uniform marker segmentation and less motion blur. Conclusion: Image quality was visibly and significantly improved with projection sharing. Projection sharing does not require any modifications to existing hardware and offers a more robust replacement to phase based binning, or, an option if phase based reconstruction is not of a

  3. Image processing tensor transform and discrete tomography with Matlab

    CERN Document Server

    Grigoryan, Artyom M

    2012-01-01

    Focusing on mathematical methods in computer tomography, Image Processing: Tensor Transform and Discrete Tomography with MATLAB(R) introduces novel approaches to help in solving the problem of image reconstruction on the Cartesian lattice. Specifically, it discusses methods of image processing along parallel rays to more quickly and accurately reconstruct images from a finite number of projections, thereby avoiding overradiation of the body during a computed tomography (CT) scan. The book presents several new ideas, concepts, and methods, many of which have not been published elsewhere. New co

  4. Opting out of the peaceful use of nuclear power in Germany. A promising special approach in the European context?

    International Nuclear Information System (INIS)

    Buedenbender, Martin

    2009-01-01

    Nuclear power is in the focus of politics and public attention in Germany not only because of the federal elections. Again and again, voices are heard which doubt the decision taken in 2000 to opt out of the use of nuclear power. The change in parliamentary majority in favor of the alliance of CDU/CSU and FDP as a result of the elections on September 27 is leading to another review of the opt-out decision, as the three parties in their platforms expressed themselves in favor of extending nuclear power plant life. This makes a stocktaking exercise of all salient arguments imperative at the present juncture. The perspective in that case should not be restricted to national aspects but include especially the influence of the European dimension of the subject. Present political positions in the 27 EU countries indicate a renaissance of nuclear power. Numerous countries, such as Italy, Sweden, Poland or the United Kingdom, revoked their historic opt-out decisions, are using nuclear power for the first time, or want to expand greatly the nuclear share in their electricity generation mix. All 3 European agencies with clear majorities advocate the extensive use of nuclear power as a long-term component of the mix of energy resources. Germany, with its decision to opt out of the use of nuclear power, is part of a minority. Being part of a European electricity market which will grow together more and more closely up to complete integration, Germany will always be supplied electricity from nuclear sources in the long run. This will be true irrespective of nuclear power plants being operated in the country. So, shutting down German nuclear power plants will not achieve the goals of nuclear opponents but merely give rise to additional challenges in power technology in an effort to ensure Germany's electricity supply. For this reason, the new German federal government should revoke the decision to opt out of the peaceful use of nuclear power. (orig.)

  5. A 10-year population based study of 'opt-out' HIV testing of tuberculosis patients in Alberta, Canada: national implications.

    Directory of Open Access Journals (Sweden)

    Richard Long

    Full Text Available Compliance with the recommendation that all tuberculosis (TB patients be tested for human immunodeficiency virus (HIV has not yet been achieved in Canada or globally.The experience of "opt-out" HIV testing of TB patients in the Province of Alberta, Canada is described over a 10-year period, 2003-2012. Testing rates are reported before and after the introduction of the "opt-out" approach. Risk factors for HIV seropositivity are described and demographic, clinical and laboratory characteristics of TB patients who were newly diagnosed versus previously diagnosed with HIV are compared. Genotypic clusters, defined as groups of two or more cases whose isolates of Mycobacterium tuberculosis had identical DNA fingerprints over the 10-year period or within 2 years of one another, were analyzed for their ability to predict HIV co-infection.HIV testing rates were 26% before and 90% after the introduction of "opt-out" testing. During the "opt-out" testing years those 64 years of age at diagnosis were less likely to have been tested. In those tested the prevalence of HIV was 5.6%. In the age group 15-64 years, risk factors for HIV were: age (35-64 years, Canadian-born Aboriginal or foreign-born sub-Saharan African origin, and combined respiratory and non-respiratory disease. Compared to TB patients previously known to be HIV positive, TB patients newly discovered to be HIV positive had more advanced HIV disease (lower CD4 counts; higher viral loads at diagnosis. Large cluster size was associated with Aboriginal ancestry. Cluster size predicted HIV co-infection in Aboriginal peoples when clusters included all cases reported over 10 years but not when clusters included cases reported within 2 years of one another."Opt-out" HIV testing of TB patients is effective and well received. Universal HIV testing of TB patients (>80% of patients tested has immediate (patients and longer-term (TB/HIV program planning benefits.

  6. Principles of medical imaging with emphasis on tomography

    Energy Technology Data Exchange (ETDEWEB)

    Kouris, K [Institute of Nuclear Medicine, University College, London Medical School, Mortimer Street, London W1N 8AA (United Kingdom)

    1994-12-31

    Medical imaging with ionizing and non-ionizing radiations belongs to the class of problems known as indirect sensing. This article is concerned with imaging methods known as image reconstruction from projections or computerized tomography. A brief comparative study of the theory is presented. Depending on the nature and modes of propagation of the employed radiation, methods are discussed either under transmission tomography (with gamma rays and X rays) or emission tomography (with gamma rays and positrons). Magnetic resonance Imaging (MRI) is described as resonant absorption and re-emission of radiofrequency energy. (author). 6 refs, 1 fig.

  7. Victims, vectors and villains: are those who opt out of vaccination morally responsible for the deaths of others?

    Science.gov (United States)

    Jamrozik, Euzebiusz; Handfield, Toby; Selgelid, Michael J

    2016-12-01

    Mass vaccination has been a successful public health strategy for many contagious diseases. The immunity of the vaccinated also protects others who cannot be safely or effectively vaccinated-including infants and the immunosuppressed. When vaccination rates fall, diseases like measles can rapidly resurge in a population. Those who cannot be vaccinated for medical reasons are at the highest risk of severe disease and death. They thus may bear the burden of others' freedom to opt out of vaccination. It is often asked whether it is legitimate for states to adopt and enforce mandatory universal vaccination. Yet this neglects a related question: are those who opt out, where it is permitted, morally responsible when others are harmed or die as a result of their decision? In this article, we argue that individuals who opt out of vaccination are morally responsible for resultant harms to others. Using measles as our main example, we demonstrate the ways in which opting out of vaccination can result in a significant risk of harm and death to others, especially infants and the immunosuppressed. We argue that imposing these risks without good justification is blameworthy and examine ways of reaching a coherent understanding of individual moral responsibility for harms in the context of the collective action required for disease transmission. Finally, we consider several objections to this view, provide counterarguments and suggest morally permissible alternatives to mandatory universal vaccination including controlled infection, self-imposed social isolation and financial penalties for refusal to vaccinate. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.

  8. Measuring techniques in emission computed tomography

    International Nuclear Information System (INIS)

    Jordan, K.; Knoop, B.

    1988-01-01

    The chapter reviews the historical development of the emission computed tomography and its basic principles, proceeds to SPECT and PET, special techniques of emission tomography, and concludes with a comprehensive discussion of the mathematical fundamentals of the reconstruction and the quantitative activity determination in vivo, dealing with radon transformation and the projection slice theorem, methods of image reconstruction such as analytical and algebraic methods, limiting conditions in real systems such as limited number of measured data, noise enhancement, absorption, stray radiation, and random coincidence. (orig./HP) With 111 figs., 6 tabs [de

  9. Dose fractionation theorem in 3-D reconstruction (tomography)

    Energy Technology Data Exchange (ETDEWEB)

    Glaeser, R.M. [Lawrence Berkeley National Lab., CA (United States)

    1997-02-01

    It is commonly assumed that the large number of projections for single-axis tomography precludes its application to most beam-labile specimens. However, Hegerl and Hoppe have pointed out that the total dose required to achieve statistical significance for each voxel of a computed 3-D reconstruction is the same as that required to obtain a single 2-D image of that isolated voxel, at the same level of statistical significance. Thus a statistically significant 3-D image can be computed from statistically insignificant projections, as along as the total dosage that is distributed among these projections is high enough that it would have resulted in a statistically significant projection, if applied to only one image. We have tested this critical theorem by simulating the tomographic reconstruction of a realistic 3-D model created from an electron micrograph. The simulations verify the basic conclusions of high absorption, signal-dependent noise, varying specimen contrast and missing angular range. Furthermore, the simulations demonstrate that individual projections in the series of fractionated-dose images can be aligned by cross-correlation because they contain significant information derived from the summation of features from different depths in the structure. This latter information is generally not useful for structural interpretation prior to 3-D reconstruction, owing to the complexity of most specimens investigated by single-axis tomography. These results, in combination with dose estimates for imaging single voxels and measurements of radiation damage in the electron microscope, demonstrate that it is feasible to use single-axis tomography with soft X-ray microscopy of frozen-hydrated specimens.

  10. Dose fractionation theorem in 3-D reconstruction (tomography)

    International Nuclear Information System (INIS)

    Glaeser, R.M.

    1997-01-01

    It is commonly assumed that the large number of projections for single-axis tomography precludes its application to most beam-labile specimens. However, Hegerl and Hoppe have pointed out that the total dose required to achieve statistical significance for each voxel of a computed 3-D reconstruction is the same as that required to obtain a single 2-D image of that isolated voxel, at the same level of statistical significance. Thus a statistically significant 3-D image can be computed from statistically insignificant projections, as along as the total dosage that is distributed among these projections is high enough that it would have resulted in a statistically significant projection, if applied to only one image. We have tested this critical theorem by simulating the tomographic reconstruction of a realistic 3-D model created from an electron micrograph. The simulations verify the basic conclusions of high absorption, signal-dependent noise, varying specimen contrast and missing angular range. Furthermore, the simulations demonstrate that individual projections in the series of fractionated-dose images can be aligned by cross-correlation because they contain significant information derived from the summation of features from different depths in the structure. This latter information is generally not useful for structural interpretation prior to 3-D reconstruction, owing to the complexity of most specimens investigated by single-axis tomography. These results, in combination with dose estimates for imaging single voxels and measurements of radiation damage in the electron microscope, demonstrate that it is feasible to use single-axis tomography with soft X-ray microscopy of frozen-hydrated specimens

  11. Weighted expectation maximization reconstruction algorithms with application to gated megavoltage tomography

    International Nuclear Information System (INIS)

    Zhang Jin; Shi Daxin; Anastasio, Mark A; Sillanpaa, Jussi; Chang Jenghwa

    2005-01-01

    We propose and investigate weighted expectation maximization (EM) algorithms for image reconstruction in x-ray tomography. The development of the algorithms is motivated by the respiratory-gated megavoltage tomography problem, in which the acquired asymmetric cone-beam projections are limited in number and unevenly sampled over view angle. In these cases, images reconstructed by use of the conventional EM algorithm can contain ring- and streak-like artefacts that are attributable to a combination of data inconsistencies and truncation of the projection data. By use of computer-simulated and clinical gated fan-beam megavoltage projection data, we demonstrate that the proposed weighted EM algorithms effectively mitigate such image artefacts. (note)

  12. Single photon emission computerized tomography (SPECT)

    International Nuclear Information System (INIS)

    Ganatra, R.D.

    1992-01-01

    Tomography in nuclear medicine did not originate after the introduction of X-ray computerized tomography (CT). Even in the days of rectilinear scanner, tomography was attempted with multiple detector heads rotating around the patient, but the counts at each plane were never very high to obtain a satisfactory image. A high resolution focusing collimator can look at different depths but taking several slices in one projection was a time consuming process. Rectilinear scanners lose lot of counts in the collimator to look at one point, at on time, in one plane. It is true that attempts to do tomography with gamma camera really got a boost after the success of CT. By that time, algorithms for doing reconstruction of images also were highly refined and for advanced. Clinical application of SPECT has become widespread now, because of the development of suitable radiopharmaceuticals and improvement in instrumentation. The SPECT provides a direct measure of regional organ function and is performed with nuclides such as 123 I and 99 Tc m that emit a mono-image photon during their decay. SPECT is far less expensive than positron emission tomography

  13. Single photon emission computerized tomography (SPECT)

    Energy Technology Data Exchange (ETDEWEB)

    Ganatra, R D

    1993-12-31

    Tomography in nuclear medicine did not originate after the introduction of X-ray computerized tomography (CT). Even in the days of rectilinear scanner, tomography was attempted with multiple detector heads rotating around the patient, but the counts at each plane were never very high to obtain a satisfactory image. A high resolution focusing collimator can look at different depths but taking several slices in one projection was a time consuming process. Rectilinear scanners lose lot of counts in the collimator to look at one point, at on time, in one plane. It is true that attempts to do tomography with gamma camera really got a boost after the success of CT. By that time, algorithms for doing reconstruction of images also were highly refined and for advanced. Clinical application of SPECT has become widespread now, because of the development of suitable radiopharmaceuticals and improvement in instrumentation. The SPECT provides a direct measure of regional organ function and is performed with nuclides such as {sup 123}I and {sup 99}Tc{sup m} that emit a mono-image photon during their decay. SPECT is far less expensive than positron emission tomography

  14. Evolution/Creationism Controversy: Analysis of Past and Current Policies in Public Schools and the Practice of Allowing Students to Opt Out of Learning Evolution Concepts

    Science.gov (United States)

    Speake, Jacquelyn Hoffmann

    2011-07-01

    Recent anti-evolution legislation, in the form of Academic Freedom bills, has been introduced in many state legislatures over the last three years. The language in the proposed Academic Freedom bills may allow different interpretations of what can be taught in the science classrooms, and possibly spur parents to take advantage of their perceived parental rights to request their child be opted-out of class when the scientific theory of evolution is taught. Five research questions guided the analysis of participant responses to questions and perception statements focusing on secondary school administrators' actions, perceptions, and awareness as they relate to their decision to allow or not allow a student to opt out of academics, specifically evolution, through the collection of data using a web-based survey. Opt out policies are typically invoked to excuse students from activities to which they or their parents may have religious objections (Scott & Branch, 2008). Florida statutes allow parents to opt out their child from human sexuality and animal dissection. The population consisted of 281 Florida public secondary school administrators, who were divided into two subgroups based on whether they have allowed or would allow a student to opt out of evolution, or have not allowed or would not allow a student to opt out of class when the scientific theory of evolution is taught. Results found that over 70% of the administrators who completed the survey have allowed or would allow parents to opt out their child from learning about the scientific theory of evolution. There was a significant relationship between the decision to allow opt out and the following variables: (a) Free and Reduced Lunch population, (b) grade level served, (c) support for teaching evolution and alternative theories, and (d) the perception that parent rights supersede state statute requiring students to learn evolution. In Florida, any scientific concept that is based on empirical evidence is

  15. Is opting out of the peaceful uses of nuclear power a responsible approach to take?

    International Nuclear Information System (INIS)

    Becker, K.

    1999-01-01

    This was the topic of an Expert Meeting arranged by the VDI-Gesellschaft fuer Energietechnik at the Berlin Palace Hotel on September 28-29, 1999 and attended by roughly one hundred experts, almost exclusively from Germany. The meeting was organized to examine the economic impact of Germany's sole opting out of a high technology in the face of a growing worldwide energy requirement, and whether this approach will allow the objectives of carbon dioxide reduction to be achieved in the interest of climate protection. The detailed points discussed at the meeting included the economic consequences for Germany arising from the country's opting out of the use of nuclear power; the preservation of competence in nuclear technology; the future role of nuclear power in the EU; the energy options existing for climate protection. In addition, political discussions were held with representatives of the political parties. (orig.) [de

  16. Magnified Weak Lensing Cross Correlation Tomography

    Energy Technology Data Exchange (ETDEWEB)

    Ulmer, Melville P., Clowe, Douglas I.

    2010-11-30

    This project carried out a weak lensing tomography (WLT) measurement around rich clusters of galaxies. This project used ground based photometric redshift data combined with HST archived cluster images that provide the WLT and cluster mass modeling. The technique has already produced interesting results (Guennou et al, 2010,Astronomy & Astrophysics Vol 523, page 21, and Clowe et al, 2011 to be submitted). Guennou et al have validated that the necessary accuracy can be achieved with photometric redshifts for our purposes. Clowe et al titled "The DAFT/FADA survey. II. Tomographic weak lensing signal from 10 high redshift clusters," have shown that for the **first time** via this purely geometrical technique, which does not assume a standard rod or candle, that a cosmological constant is **required** for flat cosmologies. The intent of this project is not to produce the best constraint on the value of the dark energy equation of state, w. Rather, this project is to carry out a sustained effort of weak lensing tomography that will naturally feed into the near term Dark Energy Survey (DES) and to provide invaluable mass calibration for that project. These results will greatly advance a key cosmological method which will be applied to the top-rated ground-based project in the Astro2020 decadal survey, LSST. Weak lensing tomography is one of the key science drivers behind LSST. CO-I Clowe is on the weak lensing LSST committee, and senior scientist on this project, at FNAL James Annis, plays a leading role in the DES. This project has built on successful proposals to obtain ground-based imaging for the cluster sample. By 1 Jan, it is anticipated the project will have accumulated complete 5-color photometry on 30 (or about 1/3) of the targeted cluster sample (public webpage for the survey is available at http://cencos.oamp.fr/DAFT/ and has a current summary of the observational status of various clusters). In all, the project has now been awarded the equivalent of over 60

  17. 17 CFR 248.13 - Exception to opt out requirements for service providers and joint marketing.

    Science.gov (United States)

    2010-04-01

    ... include marketing of your own products or services or marketing of financial products or services offered... requirements for service providers and joint marketing. 248.13 Section 248.13 Commodity and Securities... Consumer Financial Information and Safeguarding Personal Information Exceptions § 248.13 Exception to opt...

  18. SU-E-I-73: Clinical Evaluation of CT Image Reconstructed Using Interior Tomography

    International Nuclear Information System (INIS)

    Zhang, J; Ge, G; Winkler, M; Cong, W; Wang, G

    2014-01-01

    Purpose: Radiation dose reduction has been a long standing challenge in CT imaging of obese patients. Recent advances in interior tomography (reconstruction of an interior region of interest (ROI) from line integrals associated with only paths through the ROI) promise to achieve significant radiation dose reduction without compromising image quality. This study is to investigate the application of this technique in CT imaging through evaluating imaging quality reconstructed from patient data. Methods: Projection data were directly obtained from patients who had CT examinations in a Dual Source CT scanner (DSCT). Two detectors in a DSCT acquired projection data simultaneously. One detector provided projection data for full field of view (FOV, 50 cm) while another detectors provided truncated projection data for a FOV of 26 cm. Full FOV CT images were reconstructed using both filtered back projection and iterative algorithm; while interior tomography algorithm was implemented to reconstruct ROI images. For comparison reason, FBP was also used to reconstruct ROI images. Reconstructed CT images were evaluated by radiologists and compared with images from CT scanner. Results: The results show that the reconstructed ROI image was in excellent agreement with the truth inside the ROI, obtained from images from CT scanner, and the detailed features in the ROI were quantitatively accurate. Radiologists evaluation shows that CT images reconstructed with interior tomography met diagnosis requirements. Radiation dose may be reduced up to 50% using interior tomography, depending on patient size. Conclusion: This study shows that interior tomography can be readily employed in CT imaging for radiation dose reduction. It may be especially useful in imaging obese patients, whose subcutaneous tissue is less clinically relevant but may significantly increase radiation dose

  19. Mathematics of Computed Tomography

    Science.gov (United States)

    Hawkins, William Grant

    A review of the applications of the Radon transform is presented, with emphasis on emission computed tomography and transmission computed tomography. The theory of the 2D and 3D Radon transforms, and the effects of attenuation for emission computed tomography are presented. The algebraic iterative methods, their importance and limitations are reviewed. Analytic solutions of the 2D problem the convolution and frequency filtering methods based on linear shift invariant theory, and the solution of the circular harmonic decomposition by integral transform theory--are reviewed. The relation between the invisible kernels, the inverse circular harmonic transform, and the consistency conditions are demonstrated. The discussion and review are extended to the 3D problem-convolution, frequency filtering, spherical harmonic transform solutions, and consistency conditions. The Cormack algorithm based on reconstruction with Zernike polynomials is reviewed. An analogous algorithm and set of reconstruction polynomials is developed for the spherical harmonic transform. The relations between the consistency conditions, boundary conditions and orthogonal basis functions for the 2D projection harmonics are delineated and extended to the 3D case. The equivalence of the inverse circular harmonic transform, the inverse Radon transform, and the inverse Cormack transform is presented. The use of the number of nodes of a projection harmonic as a filter is discussed. Numerical methods for the efficient implementation of angular harmonic algorithms based on orthogonal functions and stable recursion are presented. The derivation of a lower bound for the signal-to-noise ratio of the Cormack algorithm is derived.

  20. Poster — Thur Eve — 01: The effect of the number of projections on MTF and CNR in Compton scatter tomography

    International Nuclear Information System (INIS)

    Chighvinadze, T; Pistorius, S

    2014-01-01

    Purpose: To investigate the dependence of the reconstructed image quality on the number of projections in multi-projection Compton scatter tomography (MPCST). The conventional relationship between the projection number used for reconstruction and reconstructed image quality pertained to CT does not necessarily apply to MPCST, which can produce images from a single projection if the detectors have sufficiently high energy and spatial resolution. Methods: The electron density image was obtained using filtered-backprojection of the scatter signal over circular arcs formed using Compton equation. The behavior of the reconstructed image quality as a function of the projection number was evaluated through analytical simulations and characterized by CNR and MTF. Results: The increase of the projection number improves the contrast with this dependence being a function of fluence. The number of projections required to approach the asymptotic maximum contrast decreases as the fluence increases. Increasing projection number increases the CNR but not spatial resolution. Conclusions: For MPCST using a 500eV energy resolution and a 2×2mm 2 size detector, an adequate image quality can be obtained with a small number of projections provided the incident fluence is high enough. This is conceptually different from conventional CT where a minimum number of projections is required to obtain an adequate image quality. While increasing projection number, even for the lowest dose value, the CNR increases even though the number of photons per projection decreases. The spatial resolution of the image is improved by increasing the sampling within a projection rather than by increasing the number of projections

  1. Preliminary investigations on high energy electron beam tomography

    Energy Technology Data Exchange (ETDEWEB)

    Baertling, Yves; Hoppe, Dietrich; Hampel, Uwe

    2010-12-15

    In computed tomography (CT) cross-sectional images of the attenuation distribution within a slice are created by scanning radiographic projections of an object with a rotating X-ray source detector compound and subsequent reconstruction of the images from these projection data on a computer. CT can be made very fast by employing a scanned electron beam instead of a mechanically moving X-ray source. Now this principle was extended towards high-energy electron beam tomography with an electrostatic accelerator. Therefore a dedicated experimental campaign was planned and carried out at the Budker Institute of Nuclear Physics (BINP), Novosibirsk. There we investigated the capabilities of BINP's accelerators as an electron beam generating and scanning unit of a potential high-energy electron beam tomography device. The setup based on a 1 MeV ELV-6 (BINP) electron accelerator and a single detector. Besides tomographic measurements with different phantoms, further experiments were carried out concerning the focal spot size and repeat accuracy of the electron beam as well as the detector's response time and signal to noise ratio. (orig.)

  2. Opt-Out Patient Navigation to Improve Breast and Cervical Cancer Screening Among Homeless Women.

    Science.gov (United States)

    Asgary, Ramin; Naderi, Ramesh; Wisnivesky, Juan

    2017-09-01

    A patient navigation model was implemented to improve breast and cervical cancer screening among women who were homeless in five shelters and shelter clinics in New York City in 2014. Navigation consisted of opt-out screening to eligible women; cancer health and screening education; scheduling and following up for screening completion, obtaining, and communicating results to patients and providers; and care coordination with social services organizations. Women (n = 162, aged 21-74, 58% black) completed mammogram (88%) and Pap testing (83%) from baselines of 59% and 50%, respectively. There was no association between mental health or substance abuse and screening completion. Adjusted analysis showed a significant association between refusing/missing Pap testing and older age (odds ratio [OR] 1.12, 95% confidence interval [CI] 1.04-1.20); independent predictors of mammogram included more pregnancies (OR 0.57, 95% CI 0.37-0.88) and older age (OR 0.84, 95% CI 0.79-0.90). Opt-out patient navigation is feasible and effective and may mitigate multilevel barriers to cancer screening among women with unstable housing.

  3. Eurasia: The Rivalry of Global Integration Projects

    Directory of Open Access Journals (Sweden)

    Olesia Kobenko

    2016-05-01

    Full Text Available The article reveals the Eurasian integration projects as major drivers of world globalization. Eurasian regionalism seems to be gaining attention in the scientific literature. Under the current political circumstance many regions are accelerating integration and many countries are opting for regional associations as a mechanism to help them overcome the global recession. Moreover, the global political leaders , some developed countries - the U.S., China, and the European Union (EU are interested to set up regional economic blocs such as Eurasian Economic Union (The EEU, the China's project 'One Belt One Road', the U.S's projects - The Trans-Pacific Partnership (TPP and The Transatlantic Trade and Investment Partnership (TTIP. The goal of this paper is to introduce a number of integration initiatives and to analyze the current strategies of Eurasian regionalism.

  4. Modeling Atom Probe Tomography: A review

    Energy Technology Data Exchange (ETDEWEB)

    Vurpillot, F., E-mail: francois.vurpillot@univ-rouen.fr [Groupe de Physique des Matériaux, UMR CNRS 6634, Université de Rouen, Saint Etienne du Rouvray 76801 (France); Oberdorfer, C. [Institut für Materialwissenschaft, Lehrstuhl für Materialphysik, Universität Stuttgart, Heisenbergstr. 3, 70569 Stuttgart (Germany)

    2015-12-15

    Improving both the precision and the accuracy of Atom Probe Tomography reconstruction requires a correct understanding of the imaging process. In this aim, numerical modeling approaches have been developed for 15 years. The injected ingredients of these modeling tools are related to the basic physic of the field evaporation mechanism. The interplay between the sample nature and structure of the analyzed sample and the reconstructed image artefacts have pushed to gradually improve and make the model more and more sophisticated. This paper reviews the evolution of the modeling approach in Atom Probe Tomography and presents some future potential directions in order to improve the method. - Highlights: • The basics of field evaporation. • The main aspects of Atom Probe Tomography modeling. • The intrinsic limitations of the current method and future potential directions to improve the understanding of tip to image ion projection.

  5. Quantitative damage imaging using Lamb wave diffraction tomography

    International Nuclear Information System (INIS)

    Zhang Hai-Yan; Ruan Min; Zhu Wen-Fa; Chai Xiao-Dong

    2016-01-01

    In this paper, we investigate the diffraction tomography for quantitative imaging damages of partly through-thickness holes with various shapes in isotropic plates by using converted and non-converted scattered Lamb waves generated numerically. Finite element simulations are carried out to provide the scattered wave data. The validity of the finite element model is confirmed by the comparison of scattering directivity pattern (SDP) of circle blind hole damage between the finite element simulations and the analytical results. The imaging method is based on a theoretical relation between the one-dimensional (1D) Fourier transform of the scattered projection and two-dimensional (2D) spatial Fourier transform of the scattering object. A quantitative image of the damage is obtained by carrying out the 2D inverse Fourier transform of the scattering object. The proposed approach employs a circle transducer network containing forward and backward projections, which lead to so-called transmission mode (TMDT) and reflection mode diffraction tomography (RMDT), respectively. The reconstructed results of the two projections for a non-converted S0 scattered mode are investigated to illuminate the influence of the scattering field data. The results show that Lamb wave diffraction tomography using the combination of TMDT and RMDT improves the imaging effect compared with by using only the TMDT or RMDT. The scattered data of the converted A0 mode are also used to assess the performance of the diffraction tomography method. It is found that the circle and elliptical shaped damages can still be reasonably identified from the reconstructed images while the reconstructed results of other complex shaped damages like crisscross rectangles and racecourse are relatively poor. (special topics)

  6. Vanishing vaccinations: why are so many Americans opting out of vaccinating their children?

    Science.gov (United States)

    Calandrillo, Steve P

    2004-01-01

    Vaccinations against life-threatening diseases are one of the greatest public health achievements in history. Literally millions of premature deaths have been prevented, and countless more children have been saved from disfiguring illness. While vaccinations carry unavoidable risks, the medical, social and economic benefits they confer have led all fifty states to enact compulsory childhood vaccination laws to stop the spread of preventable diseases. Today, however, vaccines are becoming a victim of their success--many individuals have never witnessed the debilitating diseases that vaccines protect against, allowing complacency toward immunization requirements to build. Antivaccination sentiment is growing fast in the United States, in large part due to the controversial and hotly disputed link between immunizations and autism. The internet worsens fears regarding vaccination safety, as at least a dozen websites publish alarming information about the risks of vaccines. Increasing numbers of parents are refusing immunizations for their children and seeking legally sanctioned exemptions instead, apparently fearing vaccines more than the underlying diseases that they protect against. A variety of factors are at play: religious and philosophical beliefs, freedom and individualism, misinformation about risk, and overperception of risk. State legislatures and health departments now face a difficult challenge: respecting individual rights and freedoms while also safeguarding the public welfare. Nearly all states allow vaccination exemptions for religious reasons and a growing number provide "philosophical" opt-outs as well. However, in all but a handful of jurisdictions, neither objection is seriously documented or verified. Often, the law requires a parent to do no more than simply check a box indicating she does not wish her child to receive immunizations. The problem is exacerbated by financial incentives schools have to encourage students to opt out of vaccinations

  7. The new cold neutron tomography set-up at SINQ

    CERN Document Server

    Baechler, S; Cauwels, P; Dierick, M; Jolie, J; Materna, T; Mondelaers, W

    2002-01-01

    A new cold neutron tomography set-up is operational at the neutron spallation source SINQ of the Paul Scherrer Institute (PSI) in Villigen, Switzerland. The detection system is based on a sup 6 LiF/ZnS:Ag conversion screen and a CCD camera. Several tests have been carried out to characterize the quality of the tomography system, such as homogeneity, reproducibility, L/D-ratio and spatial resolution. The high flux and the good efficiency of the detector lead to very short exposure times. Thus, a typical set of tomography scans can be performed in only 20 min. Then, 3D computed tomography objects were calculated using the filtered back-projection reconstruction method. Initial results of various samples show that cold neutron tomography can be a useful tool for industry, geology and dentistry. Furthermore, suitable applications can be found in the field of archaeology.

  8. Mathematics in computed tomography and related techniques

    International Nuclear Information System (INIS)

    Sawicka, B.

    1992-01-01

    The mathematical basis of computed tomography (CT) was formulated in 1917 by Radon. His theorem states that the 2-D function f(x,y) can be determined at all points from a complete set of its line integrals. Modern methods of image reconstruction include three approaches: algebraic reconstruction techniques with simultaneous iterative reconstruction or simultaneous algebraic reconstruction; convolution back projection; and the Fourier transform method. There is no one best approach. Because the experimental data do not strictly satisfy theoretical models, a number of effects have to be taken into account; in particular, the problems of beam geometry, finite beam dimensions and distribution, beam scattering, and the radiation source spectrum. Tomography with truncated data is of interest, employing mathematical approximations to compensate for the unmeasured projection data. Mathematical techniques in image processing and data analysis are also extensively used. 13 refs

  9. Coupling two iteratives algorithms for density measurements by computerized tomography

    International Nuclear Information System (INIS)

    Silva, L.E.M.C.; Santos, C.A.C.; Borges, J.C.; Frenkel, A.D.B.; Rocha, G.M.

    1986-01-01

    This work develops a study for coupling two iteratives algotithms for density measurements by computerized tomography. Tomographies have been obtained with an automatized prototype, controled by a microcomputer, projected and assembled in the Nuclear Instrumentation Laboratory, at COPPE/UFRJ. Results show a good performance of the tomographic system, and demonstrate the validity of the method of calculus adopted. (Author) [pt

  10. Optimizing 4D cone beam computed tomography acquisition by varying the gantry velocity and projection time interval

    International Nuclear Information System (INIS)

    O’Brien, Ricky T; Cooper, Benjamin J; Keall, Paul J

    2013-01-01

    Four dimensional cone beam computed tomography (4DCBCT) is an emerging clinical image guidance strategy for tumour sites affected by respiratory motion. In current generation 4DCBCT techniques, both the gantry rotation speed and imaging frequency are constant and independent of the patient’s breathing which can lead to projection clustering. We present a mixed integer quadratic programming (MIQP) model for respiratory motion guided-4DCBCT (RMG-4DCBCT) which regulates the gantry velocity and projection time interval, in response to the patient’s respiratory signal, so that a full set of evenly spaced projections can be taken in a number of phase, or displacement, bins during the respiratory cycle. In each respiratory bin, an image can be reconstructed from the projections to give a 4D view of the patient’s anatomy so that the motion of the lungs, and tumour, can be observed during the breathing cycle. A solution to the full MIQP model in a practical amount of time, 10 s, is not possible with the leading commercial MIQP solvers, so a heuristic method is presented. Using parameter settings typically used on current generation 4DCBCT systems (4 min image acquisition, 1200 projections, 10 respiratory bins) and a sinusoidal breathing trace with a 4 s period, we show that the root mean square (RMS) of the angular separation between projections with displacement binning is 2.7° using existing constant gantry speed systems and 0.6° using RMG-4DCBCT. For phase based binning the RMS is 2.7° using constant gantry speed systems and 2.5° using RMG-4DCBCT. The optimization algorithm presented is a critical step on the path to developing a system for RMG-4DCBCT. (paper)

  11. The OptIC Data Assimilation Intercomparison: A Statistical Critique

    Science.gov (United States)

    Enting, I. G.; Clisby, N.

    2008-12-01

    The development of improved terrestrial carbon models has assumed great importance because of concerns about significant climate-to-carbon feedback processes. The complexity of the interactions leads to considerable difficulties in the process of model calibration. The OptIC intercomparison explored some aspects of model calibration, using an idealised terrestrial carbon model. Participants were invited to estimate model parameters in various cases defined by specified time series of the model state, with various forms of added noise. The study identified the crucial importance of the choice of cost function. The present analysis revisits the OptIC study, by considering it as an exercise in statistical estimation. This treats the observations as random variables. Consequently parameter estimates, â, based on observations will also be random variables whose distribution is known as the 'sampling distribution'. Key questions for any specific case are: Are departures from â/a_true =1 indication of bias or sampling error? Under what circumstance are uncertainty estimates (of Var[â]) reliable? We consider cases where the estimate is obtained by minimising a cost function, ΘX. Assuming that we know the true form of ℓ, the log likelihood, there are three different characterisations of uncertainty that should be distinguished: (i) The uncertainty from maximum-likelihood estimates, corresponding (either exactly or asymptotically) to the Cramer-Rao bound. In a realistic calibration situation, we won't be able to determine this because the 'true' form of the likelihood is unknown. (ii) The actual uncertainty associated with using a particular cost function. If the true noise distribution is known, this can be calculated in simple cases and determined from simulations in more complicated cases. (iii) The 'formal uncertainty' based on assuming (usually incorrectly) that ΘX is the true likelihood. In the first stage of the analysis, the distinctions are illustrated by

  12. Economic impact of the Commission's 'opt-out' proposal on the use of approved GM crops

    NARCIS (Netherlands)

    Hoste, R.; Wagenberg, van C.P.A.; Wijnands, J.H.M.

    2015-01-01

    The European Commission proposed the opportunity for individual EU Member States to restrict or prohibit the use of GMOs in food or feed on their territory (a national ‘opt-out’). The economic impact on individual sectors of the feed and food chain (the vegetable oil and meal industry, trade, animal

  13. Piecewise-Constant-Model-Based Interior Tomography Applied to Dentin Tubules

    Directory of Open Access Journals (Sweden)

    Peng He

    2013-01-01

    Full Text Available Dentin is a hierarchically structured biomineralized composite material, and dentin’s tubules are difficult to study in situ. Nano-CT provides the requisite resolution, but the field of view typically contains only a few tubules. Using a plate-like specimen allows reconstruction of a volume containing specific tubules from a number of truncated projections typically collected over an angular range of about 140°, which is practically accessible. Classical computed tomography (CT theory cannot exactly reconstruct an object only from truncated projections, needless to say a limited angular range. Recently, interior tomography was developed to reconstruct a region-of-interest (ROI from truncated data in a theoretically exact fashion via the total variation (TV minimization under the condition that the ROI is piecewise constant. In this paper, we employ a TV minimization interior tomography algorithm to reconstruct interior microstructures in dentin from truncated projections over a limited angular range. Compared to the filtered backprojection (FBP reconstruction, our reconstruction method reduces noise and suppresses artifacts. Volume rendering confirms the merits of our method in terms of preserving the interior microstructure of the dentin specimen.

  14. Opt-Out Parental Consent in Online Surveys: Ethical Considerations.

    Science.gov (United States)

    Harris, Jane; Porcellato, Lorna

    2018-07-01

    This article aims to foster discussion and debate around seeking parental consent from young people recruited online. The growth of social media, particularly for young people, has led to increased interest in young people's online activities as both a research topic and recruitment setting. In a health-related study, which sought to recruit young people aged 13 to 18 years old from YouTuber fan communities to an online survey, the question arose of how parental consent could be sought from young people below 16 when no link existed between researcher and parents/guardians. A practical strategy is proposed which combines novel communication methods for participant information, opt-out online consent and age verification to address this issue. Strengths and limitations of these approaches are discussed.

  15. Binary moving-blocker-based scatter correction in cone-beam computed tomography with width-truncated projections: proof of concept

    Science.gov (United States)

    Lee, Ho; Fahimian, Benjamin P.; Xing, Lei

    2017-03-01

    This paper proposes a binary moving-blocker (BMB)-based technique for scatter correction in cone-beam computed tomography (CBCT). In concept, a beam blocker consisting of lead strips, mounted in front of the x-ray tube, moves rapidly in and out of the beam during a single gantry rotation. The projections are acquired in alternating phases of blocked and unblocked cone beams, where the blocked phase results in a stripe pattern in the width direction. To derive the scatter map from the blocked projections, 1D B-Spline interpolation/extrapolation is applied by using the detected information in the shaded regions. The scatter map of the unblocked projections is corrected by averaging two scatter maps that correspond to their adjacent blocked projections. The scatter-corrected projections are obtained by subtracting the corresponding scatter maps from the projection data and are utilized to generate the CBCT image by a compressed-sensing (CS)-based iterative reconstruction algorithm. Catphan504 and pelvis phantoms were used to evaluate the method’s performance. The proposed BMB-based technique provided an effective method to enhance the image quality by suppressing scatter-induced artifacts, such as ring artifacts around the bowtie area. Compared to CBCT without a blocker, the spatial nonuniformity was reduced from 9.1% to 3.1%. The root-mean-square error of the CT numbers in the regions of interest (ROIs) was reduced from 30.2 HU to 3.8 HU. In addition to high resolution, comparable to that of the benchmark image, the CS-based reconstruction also led to a better contrast-to-noise ratio in seven ROIs. The proposed technique enables complete scatter-corrected CBCT imaging with width-truncated projections and allows reducing the acquisition time to approximately half. This work may have significant implications for image-guided or adaptive radiation therapy, where CBCT is often used.

  16. Users manual for Opt-MS : local methods for simplicial mesh smoothing and untangling.

    Energy Technology Data Exchange (ETDEWEB)

    Freitag, L.

    1999-07-20

    Creating meshes containing good-quality elements is a challenging, yet critical, problem facing computational scientists today. Several researchers have shown that the size of the mesh, the shape of the elements within that mesh, and their relationship to the physical application of interest can profoundly affect the efficiency and accuracy of many numerical approximation techniques. If the application contains anisotropic physics, the mesh can be improved by considering both local characteristics of the approximate application solution and the geometry of the computational domain. If the application is isotropic, regularly shaped elements in the mesh reduce the discretization error, and the mesh can be improved a priori by considering geometric criteria only. The Opt-MS package provides several local node point smoothing techniques that improve elements in the mesh by adjusting grid point location using geometric, criteria. The package is easy to use; only three subroutine calls are required for the user to begin using the software. The package is also flexible; the user may change the technique, function, or dimension of the problem at any time during the mesh smoothing process. Opt-MS is designed to interface with C and C++ codes, ad examples for both two-and three-dimensional meshes are provided.

  17. Inter laboratory comparison on Industrial Computed Tomography

    DEFF Research Database (Denmark)

    Angel, Jais Andreas Breusch; De Chiffre, Leonardo

    An interlaboratory comparison on industrial X-ray Computed Tomography (CT) was organized by the Centre for Geometrical Metrology (CGM), Department of Mechanical Engineering, Technical University of Denmark (DTU) and carried out within the project “Centre for Industrial Application of CT scanning...

  18. Tile-Packing Tomography Is NP-hard

    DEFF Research Database (Denmark)

    Chrobak, Marek; Dürr, Christoph; Guíñez, Flavio

    2010-01-01

    Discrete tomography deals with reconstructing finite spatial objects from their projections. The objects we study in this paper are called tilings or tile-packings, and they consist of a number of disjoint copies of a fixed tile, where a tile is defined as a connected set of grid points. A row...

  19. Automated patient setup and gating using cone beam computed tomography projections

    DEFF Research Database (Denmark)

    Wan, Hanlin; Bertholet, Jenny; Ge, Jiajia

    2016-01-01

    In radiation therapy, fiducial markers are often implanted near tumors and used for patient positioning and respiratory gating purposes. These markers are then used to manually align the patients by matching the markers in the cone beam computed tomography (CBCT) reconstruction to those...

  20. Which Factors Drive the Decision to Boycott and Opt Out of Research Rankings?

    OpenAIRE

    Michael Berlemann; Justus Haucap

    2012-01-01

    This note contains an empirical analysis of the decision of German-speaking business scholars to boycott and opt out of the best known research ranking of business scholars, initiated and published by Germany’s largest business daily, Handelsblatt. Our analysis indicates that scientists who are more senior (already have a longer academic career) and scientists who have been either less successful or less eager to publish their research in internationally well renown journals with high impac...

  1. Opting for co-operation

    International Nuclear Information System (INIS)

    1987-12-01

    This report proposes a process for choosing a low-level radioactive waste management site based on the following principles: the community should volunteer and have the right to opt out of the siting process; the community should be a partner in problem-solving and decision-making throughout the process; the community should receive compensation to offset impacts and enhance local benefits; the community should have the right to select from given technical options and impact management measures; the siting task force responsible for implementation of the process must ensure that environmental safety and human health are not compromised. The Task Force recommends that: voluntary acceptance be adopted as the basic principle for the process of siting a low-level waste management facility; the emphasis given to technical assessments of options and their impacts be counterbalanced by legitimization of an active joint decision-making role for potentially affected residents; the community accepting the facility be compensated in a way that offsets all costs and leaves the community better off than it was previously; the concepts of improved management and long-term storage, with the ability to monitor and retrieve wastes, become the immediate objectives for the handling of low-level radioactive waste accumulations. The Task Force suggests a classification system for wastes based on the fundamental properties of the wastes and their management requirements rather than on their origins and administrative affiliations. The Atomic Energy Control Board should assume a more proactive role in defining and establishing acceptable approaches to low-level radioactive waste management. The Task Force did not discover any evidence that there is a health threat from existing low-level waste accumulations in Ontario. Carbon 14 may pose a particular problem, and there should be further research into the requirements of carbon 14

  2. OptFlux: an open-source software platform for in silico metabolic engineering

    DEFF Research Database (Denmark)

    Rocha, I.; Maia, P.; Evangelista, P.

    2010-01-01

    to address industrial goals. However, the use of these methods has been restricted to bioinformaticians or other expert researchers. The main aim of this work is, therefore, to provide a user-friendly computational tool for Metabolic Engineering applications. Results: OptFlux is an open-source and modular...... available a number of useful tools. Its open-source nature invites contributions by all those interested in making their methods available for the community. Given its plug-in based architecture it can be extended with new functionalities. Currently, several plug-ins are being developed, including network...

  3. Method of multiplanar emission tomography and apparatus therefor

    International Nuclear Information System (INIS)

    Gottschalk, S.C.; Smith, K.A.; Wake, R.H.

    1981-01-01

    A method of emission tomography using a gamma camera and a rotating collimator having an array of a large number of slanted, small diameter holes. A planar projection corresponding to each angular orientation assumed by the collimator is recorded. From these series of planar projections, a three-dimensional simulation model is reconstructed by an iterative algorithm which approximates the emitting object. The simulated model comprises multiple separable planes

  4. A voluntary deductible in health insurance: the more years you opt for it, the lower your premium?

    NARCIS (Netherlands)

    K.P.M. Winssen van (Kayleigh); R.C. van Kleef (Richard); W.P.M.M. van de Ven (Wynand)

    2017-01-01

    textabstractAdverse selection regarding a voluntary deductible (VD) in health insurance implies that insured only opt for a VD if they expect no (or few) healthcare expenses. This paper investigates two potential strategies to reduce adverse selection: (1) differentiating the premium to the duration

  5. A new linear back projection algorithm to electrical tomography based on measuring data decomposition

    Science.gov (United States)

    Sun, Benyuan; Yue, Shihong; Cui, Ziqiang; Wang, Huaxiang

    2015-12-01

    As an advanced measurement technique of non-radiant, non-intrusive, rapid response, and low cost, the electrical tomography (ET) technique has developed rapidly in recent decades. The ET imaging algorithm plays an important role in the ET imaging process. Linear back projection (LBP) is the most used ET algorithm due to its advantages of dynamic imaging process, real-time response, and easy realization. But the LBP algorithm is of low spatial resolution due to the natural ‘soft field’ effect and ‘ill-posed solution’ problems; thus its applicable ranges are greatly limited. In this paper, an original data decomposition method is proposed, and every ET measuring data are decomposed into two independent new data based on the positive and negative sensing areas of the measuring data. Consequently, the number of total measuring data is extended to twice as many as the number of the original data, thus effectively reducing the ‘ill-posed solution’. On the other hand, an index to measure the ‘soft field’ effect is proposed. The index shows that the decomposed data can distinguish between different contributions of various units (pixels) for any ET measuring data, and can efficiently reduce the ‘soft field’ effect of the ET imaging process. In light of the data decomposition method, a new linear back projection algorithm is proposed to improve the spatial resolution of the ET image. A series of simulations and experiments are applied to validate the proposed algorithm by the real-time performances and the progress of spatial resolutions.

  6. A new linear back projection algorithm to electrical tomography based on measuring data decomposition

    International Nuclear Information System (INIS)

    Sun, Benyuan; Yue, Shihong; Cui, Ziqiang; Wang, Huaxiang

    2015-01-01

    As an advanced measurement technique of non-radiant, non-intrusive, rapid response, and low cost, the electrical tomography (ET) technique has developed rapidly in recent decades. The ET imaging algorithm plays an important role in the ET imaging process. Linear back projection (LBP) is the most used ET algorithm due to its advantages of dynamic imaging process, real-time response, and easy realization. But the LBP algorithm is of low spatial resolution due to the natural ‘soft field’ effect and ‘ill-posed solution’ problems; thus its applicable ranges are greatly limited. In this paper, an original data decomposition method is proposed, and every ET measuring data are decomposed into two independent new data based on the positive and negative sensing areas of the measuring data. Consequently, the number of total measuring data is extended to twice as many as the number of the original data, thus effectively reducing the ‘ill-posed solution’. On the other hand, an index to measure the ‘soft field’ effect is proposed. The index shows that the decomposed data can distinguish between different contributions of various units (pixels) for any ET measuring data, and can efficiently reduce the ‘soft field’ effect of the ET imaging process. In light of the data decomposition method, a new linear back projection algorithm is proposed to improve the spatial resolution of the ET image. A series of simulations and experiments are applied to validate the proposed algorithm by the real-time performances and the progress of spatial resolutions. (paper)

  7. 40 CFR 97.288 - CAIR SO2 allowance allocations to CAIR SO2 opt-in units.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 20 2010-07-01 2010-07-01 false CAIR SO2 allowance allocations to CAIR SO2 opt-in units. 97.288 Section 97.288 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) FEDERAL NOX BUDGET TRADING PROGRAM AND CAIR NOX AND SO2 TRADING PROGRAMS...

  8. 40 CFR 96.288 - CAIR SO2 allowance allocations to CAIR SO2 opt-in units.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 20 2010-07-01 2010-07-01 false CAIR SO2 allowance allocations to CAIR SO2 opt-in units. 96.288 Section 96.288 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) NOX BUDGET TRADING PROGRAM AND CAIR NOX AND SO2 TRADING PROGRAMS FOR...

  9. Scanning transmission proton microscopy tomography of reconstruction cells from simulated data

    International Nuclear Information System (INIS)

    Zhang Conghua; Li Min; Hou Qing

    2011-01-01

    For scanning transmission proton microscopy tomography, to compare cell images of the proton stopping power and relative electron density, two cell phantoms are designed and simulated by code FLUKA. The cell images are reconstructed by the filtered back projection algorithm, and compared with their tomography imaging. The images of stopping power and relative electron density slightly vary with proton energies, but the internal images are of clear with high resolution. The organic glass image of relative electron density reveals the resolution power of proton tomography. Also, the simulation results reflect effects of the boundary enhancement, the weak artifacts, and the internal structure border extension by multiple scattering. So using proton tomography to analyze internal structure of a cell is a superior. (authors)

  10. Development of Hardware Dual Modality Tomography System

    Directory of Open Access Journals (Sweden)

    R. M. Zain

    2009-06-01

    Full Text Available The paper describes the hardware development and performance of the Dual Modality Tomography (DMT system. DMT consists of optical and capacitance sensors. The optical sensors consist of 16 LEDs and 16 photodiodes. The Electrical Capacitance Tomography (ECT electrode design use eight electrode plates as the detecting sensor. The digital timing and the control unit have been developing in order to control the light projection of optical emitters, switching the capacitance electrodes and to synchronize the operation of data acquisition. As a result, the developed system is able to provide a maximum 529 set data per second received from the signal conditioning circuit to the computer.

  11. Traveltime and waveform tomography analysis of synthetic borehole seismic data based on the CO2SINK project site, Germany

    Science.gov (United States)

    Yang, Can; Fan, Wenfang; Juhlin, Christopher

    2010-05-01

    Time lapse analysis of seismic data is very important for CO2 storage projects. Therefore, we have tested traveltime and waveform tomography methods to detect velocity changes in a CO2 injection reservoir using synthetic time lapse data. The structural model tested is based on the CO2SINK injection site at Ketzin, Germany where CO2 is being injected at about 630-650 m into a saline aquifer. First, we created synthetic time lapse moving source profiling (MSP) data, also known as walkaway profiling. The velocity model used for modeling was based on well logging and lithological information in the injection borehole. Gassmann fluid substitution was used to calculate the reservoir velocity after injection. In this substitution, we assumed a saturation of CO2 of 30%. The model velocity of the reservoir changed from 2750 m/s (before injection) to 2150 m/s (after injection). A 2D finite difference code available in Seismic Unix (www.cwp.mines.edu) was used. 60 source points were distributed along a surface line. The distance from the injection well was between 150m and 858m, with an interval of 12m. We recorded 21 channels at receiver depths from 470m to 670m, with an interval of 10m. The injection layer was assumed to be between 629m and 650m depth. The wavelet used for the synthetic data was a Gaussian derivative with an average frequency of 60Hz. Then first arrivals were picked on both data sets and used as input data for traveltime tomography. For traveltime tomography, the PS_tomo program was used. Since no data were recorded above 470m, the initial velocity model used above this depth was the true velocity model. Below 470m, the initial velocity model increases linearly from 3000m/s to 3250m/s. After inversion, the reservoir velocity and an anhydrite layer (high velocity layer) can be seen clearly in the final inverted velocity models. Using these velocity models as starting models, we performed waveform tomography in the frequency domain using a program supplied by

  12. Multi-Detector Computed Tomography Imaging Techniques in Arterial Injuries

    Directory of Open Access Journals (Sweden)

    Cameron Adler

    2018-04-01

    Full Text Available Cross-sectional imaging has become a critical aspect in the evaluation of arterial injuries. In particular, angiography using computed tomography (CT is the imaging of choice. A variety of techniques and options are available when evaluating for arterial injuries. Techniques involve contrast bolus, various phases of contrast enhancement, multiplanar reconstruction, volume rendering, and maximum intensity projection. After the images are rendered, a variety of features may be seen that diagnose the injury. This article provides a general overview of the techniques, important findings, and pitfalls in cross sectional imaging of arterial imaging, particularly in relation to computed tomography. In addition, the future directions of computed tomography, including a few techniques in the process of development, is also discussed.

  13. Correlates of HIV testing refusal among emergency department patients in the opt-out testing era.

    Science.gov (United States)

    Setse, Rosanna W; Maxwell, Celia J

    2014-05-01

    Opt-out HIV screening is recommended by the CDC for patients in all healthcare settings. We examined correlates of HIV testing refusal among urban emergency department (ED) patients. Confidential free HIV screening was offered to 32,633 ED patients in an urban tertiary care facility in Washington, DC, during May 2007-December 2011. Demographic differences in testing refusals were examined using χ(2) tests and generalized linear models. HIV testing refusal rates were 47.7 % 95 % CI (46.7-48.7), 11.7 % (11.0-12.4), 10.7 % (10.0-11.4), 16.9 % (15.9-17.9) and 26.9 % (25.6-28.2) in 2007, 2008, 2009, 2010 and 2011 respectively. Persons 33-54 years of age [adjusted prevalence ratio (APR) 1.42, (1.36-1.48)] and those ≥ 55 years [APR 1.39 (1.31-1.47)], versus 33-54 years; and females versus males [APR 1.07 (1.02-1.11)] were more likely to refuse testing. Opt-out HIV testing is feasible and sustainable in urban ED settings. Efforts are needed to encourage testing among older patients and women.

  14. Terahertz computed tomography in three-dimensional using a pyroelectric array detector

    Science.gov (United States)

    Li, Bin; Wang, Dayong; Zhou, Xun; Rong, Lu; Huang, Haochong; Wan, Min; Wang, Yunxin

    2017-05-01

    Terahertz frequency range spans from 0.1 to 10 THz. Terahertz radiation can penetrate nonpolar materials and nonmetallic materials, such as plastics, wood, and clothes. Then the feature makes the terahertz imaging have important research value. Terahertz computed tomography makes use of the penetrability of terahertz radiation and obtains three-dimensional object projection data. In the paper, continuous-wave terahertz computed tomography with a pyroelectric array detectoris presented. Compared with scanning terahertz computed tomography, a pyroelectric array detector can obtain a large number of projection data in a short time, as the acquisition mode of the array pyroelectric detector omit the projection process on the vertical and horizontal direction. With the two-dimensional cross-sectional images of the object are obtained by the filtered back projection algorithm. The two side distance of the straw wall account for 80 pixels, so it multiplied by the pixel size is equal to the diameter of the straw about 6.4 mm. Compared with the actual diameter of the straw, the relative error is 6%. In order to reconstruct the three-dimensional internal structure image of the straw, the y direction range from 70 to 150 are selected on the array pyroelectric detector and are reconstructed by the filtered back projection algorithm. As the pixel size is 80 μm, the height of three-dimensional internal structure image of the straw is 6.48 mm. The presented system can rapidly reconstruct the three-dimensional object by using a pyroelectric array detector and explores the feasibility of on non-destructive evaluation and security testing.

  15. Cost-Effective and High-Resolution Subsurface Characterization Using Hydraulic Tomography

    Science.gov (United States)

    2017-08-28

    of this project is to provide the Department of Defense (DoD) and its remediation contractors with the Hydraulic Tomography ( HT ) technology for...objective of this project is to provide the DoD and its remediation contractors with the HT technology for delineating the spatial distribution of the...SPONSOR/MONITOR’S REPORT NUMBER(S) ER-201212 The overall objective of this project is to provide the DoD and its remediation contractors with the

  16. 3D imaging of nanomaterials by discrete tomography.

    Science.gov (United States)

    Batenburg, K J; Bals, S; Sijbers, J; Kübel, C; Midgley, P A; Hernandez, J C; Kaiser, U; Encina, E R; Coronado, E A; Van Tendeloo, G

    2009-05-01

    The field of discrete tomography focuses on the reconstruction of samples that consist of only a few different materials. Ideally, a three-dimensional (3D) reconstruction of such a sample should contain only one grey level for each of the compositions in the sample. By exploiting this property in the reconstruction algorithm, either the quality of the reconstruction can be improved significantly, or the number of required projection images can be reduced. The discrete reconstruction typically contains fewer artifacts and does not have to be segmented, as it already contains one grey level for each composition. Recently, a new algorithm, called discrete algebraic reconstruction technique (DART), has been proposed that can be used effectively on experimental electron tomography datasets. In this paper, we propose discrete tomography as a general reconstruction method for electron tomography in materials science. We describe the basic principles of DART and show that it can be applied successfully to three different types of samples, consisting of embedded ErSi(2) nanocrystals, a carbon nanotube grown from a catalyst particle and a single gold nanoparticle, respectively.

  17. 3D imaging of nanomaterials by discrete tomography

    International Nuclear Information System (INIS)

    Batenburg, K.J.; Bals, S.; Sijbers, J.; Kuebel, C.; Midgley, P.A.; Hernandez, J.C.; Kaiser, U.; Encina, E.R.; Coronado, E.A.; Van Tendeloo, G.

    2009-01-01

    The field of discrete tomography focuses on the reconstruction of samples that consist of only a few different materials. Ideally, a three-dimensional (3D) reconstruction of such a sample should contain only one grey level for each of the compositions in the sample. By exploiting this property in the reconstruction algorithm, either the quality of the reconstruction can be improved significantly, or the number of required projection images can be reduced. The discrete reconstruction typically contains fewer artifacts and does not have to be segmented, as it already contains one grey level for each composition. Recently, a new algorithm, called discrete algebraic reconstruction technique (DART), has been proposed that can be used effectively on experimental electron tomography datasets. In this paper, we propose discrete tomography as a general reconstruction method for electron tomography in materials science. We describe the basic principles of DART and show that it can be applied successfully to three different types of samples, consisting of embedded ErSi 2 nanocrystals, a carbon nanotube grown from a catalyst particle and a single gold nanoparticle, respectively.

  18. The Muon Portal Project: Development of an Innovative Scanning Portal Based on Muon Tomography

    International Nuclear Information System (INIS)

    Bonanno, D.-L.; Indelicato, V.; Rocca, P.-La; Leonora, E.; Longhitano, F.; Presti, D.Lo; Petta, C.; Pugliatti, C.; Randazzo, N.; Riggi, F.; Russo, G.V.; Zappala, G.; Santagati, G.; Bonanno, G.; Antonuccio, V.; Bandieramonte, M.; Becciani, U.; Belluso, M.; Billotta, S.; Costa, A.; Massimino, P.; Pistagna, C.; Riggi, S.; Carbone, B.; Fallica, G.; Mazzillo, M.; Piana, A.; Sanfilippo, D.; Valvo, G.; Zaia, A.; Belluomo, F.; Puglisi, M.

    2013-06-01

    The Muon Portal is a recent Project [1] which aims at the construction of a 18 m 2 tracking detector for cosmic muons. This apparatus has been designed as a real-size prototype to inspect containers using the muon tomography technique, i.e. by measuring the deflection of muons when traversing high-Z materials. The detection setup is based on eight position-sensitive X-Y planes, four placed below and four above the volume to be inspected, with good tracking capabilities for charged particles. The detection planes are segmented into strips of extruded plastic scintillators with WLS fibres to transport the light produced in the scintillator material to the photo-sensors (SiPMs) at one of the fibre ends. Detailed GEANT4 simulations have been carried out under different scenarios to investigate the response of the apparatus. The tomographic images are reconstructed by tracking algorithms and suitable imaging software tools. Simulations have demonstrated the possibility to reconstruct a 3D image of the volume to be inspected in a reasonable amount of time, compatible with the requirement of a fast inspection technique. The first two of the 48 detection modules are presently under construction. (authors)

  19. Block matching sparsity regularization-based image reconstruction for incomplete projection data in computed tomography

    Science.gov (United States)

    Cai, Ailong; Li, Lei; Zheng, Zhizhong; Zhang, Hanming; Wang, Linyuan; Hu, Guoen; Yan, Bin

    2018-02-01

    In medical imaging many conventional regularization methods, such as total variation or total generalized variation, impose strong prior assumptions which can only account for very limited classes of images. A more reasonable sparse representation frame for images is still badly needed. Visually understandable images contain meaningful patterns, and combinations or collections of these patterns can be utilized to form some sparse and redundant representations which promise to facilitate image reconstructions. In this work, we propose and study block matching sparsity regularization (BMSR) and devise an optimization program using BMSR for computed tomography (CT) image reconstruction for an incomplete projection set. The program is built as a constrained optimization, minimizing the L1-norm of the coefficients of the image in the transformed domain subject to data observation and positivity of the image itself. To solve the program efficiently, a practical method based on the proximal point algorithm is developed and analyzed. In order to accelerate the convergence rate, a practical strategy for tuning the BMSR parameter is proposed and applied. The experimental results for various settings, including real CT scanning, have verified the proposed reconstruction method showing promising capabilities over conventional regularization.

  20. Effectiveness of a group opt-in session on uptake and graduation rates for pulmonary rehabilitation.

    Science.gov (United States)

    Graves, J; Sandrey, V; Graves, T; Smith, D L

    2010-08-01

    Pulmonary rehabilitation (PR) is an effective intervention in the treatment of patients with chronic obstructive pulmonary disease (COPD). Unfortunately some patients offered this treatment either fail to take up the offer or fail to complete the course. Studies have indicated a number of factors influencing uptake and completion rates. We describe the introduction of an intervention, the group opt-in session (GOIS), prior to individualised baseline assessment and entry to the PR course, with the intention being to improve uptake and completion rates. A 1.5-hour-long GOIS was offered as the first face-to-face contact to all patients referred for PR. Drop-out rates at all stages of the pathway from referral to graduation were collected on 200 patients prior to the introduction of the GOIS (non-GOIS group) and compared to the first 400 patients following introduction (the GOIS group). Possible independent predictors of course uptake and completion were examined in the GOIS group. The proportion of referred patients taking up the offer of individualised baseline assessment or a GOIS was similar (75% vs. 72.2%, p value not significant [ns]). However, since in the GOIS group the opt-in session preceded the individualised baseline assessment and some patients opted-out, a smaller proportion of referred patients underwent this assessment than in the non-GOIS group (58.7% vs. 75%, p graduated in the GOIS group (87.9% vs. 76.4%, p rates due to illness were similar in both groups (8.5% pre vs. 6.8% post, ns). However, drop-out rates not due to illness were much higher in the non-GOIS group (15.1% vs. 5.3%, p graduation rates at The North Bristol Lung Centre PR Course and reduced wasted assessments. There was no effect on initial uptake. Analysis of the behaviour of patients invited to a GOIS suggested that age, lung function and travel distance were important factors influencing patient choice.

  1. Quantitative tomography simulations and reconstruction algorithms

    International Nuclear Information System (INIS)

    Martz, H.E.; Aufderheide, M.B.; Goodman, D.; Schach von Wittenau, A.; Logan, C.; Hall, J.; Jackson, J.; Slone, D.

    2000-01-01

    X-ray, neutron and proton transmission radiography and computed tomography (CT) are important diagnostic tools that are at the heart of LLNL's effort to meet the goals of the DOE's Advanced Radiography Campaign. This campaign seeks to improve radiographic simulation and analysis so that radiography can be a useful quantitative diagnostic tool for stockpile stewardship. Current radiographic accuracy does not allow satisfactory separation of experimental effects from the true features of an object's tomographically reconstructed image. This can lead to difficult and sometimes incorrect interpretation of the results. By improving our ability to simulate the whole radiographic and CT system, it will be possible to examine the contribution of system components to various experimental effects, with the goal of removing or reducing them. In this project, we are merging this simulation capability with a maximum-likelihood (constrained-conjugate-gradient-CCG) reconstruction technique yielding a physics-based, forward-model image-reconstruction code. In addition, we seek to improve the accuracy of computed tomography from transmission radiographs by studying what physics is needed in the forward model. During FY 2000, an improved version of the LLNL ray-tracing code called HADES has been coupled with a recently developed LLNL CT algorithm known as CCG. The problem of image reconstruction is expressed as a large matrix equation relating a model for the object being reconstructed to its projections (radiographs). Using a constrained-conjugate-gradient search algorithm, a maximum likelihood solution is sought. This search continues until the difference between the input measured radiographs or projections and the simulated or calculated projections is satisfactorily small

  2. Inter laboratory comparison on Industrial Computed Tomography

    DEFF Research Database (Denmark)

    Angel, Jais Andreas Breusch; De Chiffre, Leonardo; Larsen, Erik

    The ‘CIA-CT comparison - Inter laboratory comparison on industrial Computed Tomography” is organized by DTU Department of Mechanical Engineering within the Danish project “Centre for Industrial Application of CT scanning - CIA-CT”. The project is co-financed by the Danish Ministry of Science......, Technology and Innovation. The comparison aims to collect information about measurement performance in state-of the-art industrial CT (Computed Tomography) scanning. Since CT scanning has entered the field of manufacturing and coordinate metrology, evaluation of uncertainty of measurement with assessment...

  3. Computerized tomography of the mandibular joints and masticatory muscles

    International Nuclear Information System (INIS)

    Huels, A.B.

    1981-01-01

    A methodology for computerized tomography of the mandibular joints was developed and applied in 80 test persons. Imaging of the mandibular joints is possible with a tomographic technique with 5 mm-overlap, full utilisation of the enlargement capacity of the imaging device, and combined use of transversal and coronary tomography. The method yields full latero-medial, cranio-caudal and anterior-posterior views of the condyle and fossa contours, free of interferences and of distortions caused by the projection. Positional diagnoses are thus possible as well as diagnoses of pathological structural changes. (orig./MG) [de

  4. X-ray micro-tomography system for small-animal imaging with zoom-in imaging capability

    International Nuclear Information System (INIS)

    Chun, In Kon; Cho, Myung Hye; Lee, Sang Chul; Cho, Min Hyoung; Lee, Soo Yeol

    2004-01-01

    Since a micro-tomography system capable of μm-resolution imaging cannot be used for whole-body imaging of a small laboratory animal without sacrificing its spatial resolution, it is desirable for a micro-tomography system to have local imaging capability. In this paper, we introduce an x-ray micro-tomography system capable of high-resolution imaging of a local region inside a small animal. By combining two kinds of projection data, one from a full field-of-view (FOV) scan of the whole body and the other from a limited FOV scan of the region of interest (ROI), we have obtained zoomed-in images of the ROI without any contrast anomalies commonly appearing in conventional local tomography. For experimental verification of the zoom-in imaging capability, we have integrated a micro-tomography system using a micro-focus x-ray source, a 1248 x 1248 flat-panel x-ray detector, and a precision scan mechanism. The mismatches between the two projection data caused by misalignments of the scan mechanism have been estimated with a calibration phantom, and the mismatch effects have been compensated in the image reconstruction procedure. Zoom-in imaging results of bony tissues with a spatial resolution of 10 lp mm -1 suggest that zoom-in micro-tomography can be greatly used for high-resolution imaging of a local region in small-animal studies

  5. Recent progress in plasma tomography at JET

    Czech Academy of Sciences Publication Activity Database

    Mlynář, Jan; Bielecki, J.; Craciunescu, T.; Ficker, Ondřej; Imríšek, Martin; Löffelmann, Viktor; Tomeš, Matěj; Alper, B.; Giacomelli, L.; Milocco, A.; Popovichev, S.; Schlummer, T.

    2016-01-01

    Roč. 3, č. 3 (2016), s. 26 ISSN 2336-2626. [SPPT 2016 - 27th Symposium on Plasma Physics and Technology/27./. Prague, 20.06.2016-23.06.2016] R&D Projects: GA MŠk LG14002 Institutional support: RVO:61389021 Keywords : tomography * JET * SXR * neutron * RE Subject RIV: BL - Plasma and Gas Discharge Physics

  6. Comment on "Fringe projection profilometry with nonparallel illumination: a least-squares approach"

    Science.gov (United States)

    Wang, Zhaoyang; Bi, Hongbo

    2006-07-01

    We comment on the recent Letter by Chen and Quan [Opt. Lett.30, 2101 (2005)] in which a least-squares approach was proposed to cope with the nonparallel illumination in fringe projection profilometry. It is noted that the previous mathematical derivations of the fringe pitch and carrier phase functions on the reference plane were incorrect. In addition, we suggest that the variation of carrier phase along the vertical direction should be considered.

  7. Opting For Families: Recent Trends in the Fertility of Highly Educated Women. NBER Working Paper No. 15074

    Science.gov (United States)

    Shang, Qingyan; Weinberg, Bruce A.

    2009-01-01

    Observers have argued about whether highly-educated women are opting out of their careers and for families. If so, it is natural to expect fertility to increase and, insofar as children are associated with lower employment, further declines in employment. This paper provides a comprehensive study of recent trends in the fertility of…

  8. Going "open" with mesoscopy: a new dimension on multi-view imaging.

    Science.gov (United States)

    Gualda, Emilio; Moreno, Nuno; Tomancak, Pavel; Martins, Gabriel G

    2014-03-01

    OpenSPIM and OpenSpinMicroscopy emerged as open access platforms for Light Sheet and Optical Projection Imaging, often called as optical mesoscopy techniques. Both projects can be easily reproduced using comprehensive online instructions that should foster the implementation and further development of optical imaging techniques with sample rotation control. This additional dimension in an open system offers the possibility to make multi-view microscopy easily modified and will complement the emerging commercial solutions. Furthermore, it is deeply based on other open platforms such as MicroManager and Arduino, enabling development of tailored setups for very specific biological questions. In our perspective, the open access principle of OpenSPIM and OpenSpinMicroscopy is a game-changer, helping the concepts of light sheet and optical projection tomography (OPT) to enter the mainstream of biological imaging.

  9. High energy near- and far-field ptychographic tomography at the ESRF

    Science.gov (United States)

    da Silva, Julio C.; Haubrich, Jan; Requena, Guillermo; Hubert, Maxime; Pacureanu, Alexandra; Bloch, Leonid; Yang, Yang; Cloetens, Peter

    2017-09-01

    In high-resolution tomography, one needs high-resolved projections in order to reconstruct a high-quality 3D map of a sample. X-ray ptychography is a robust technique which can provide such high-resolution 2D projections taking advantage of coherent X-rays. This technique was used in the far-field regime for a fair amount of time, but it can now also be implemented in the near-field regime. In both regimes, the technique enables not only high-resolution imaging, but also high sensitivity to the electron density of the sample. The combination with tomography makes 3D imaging possible via ptychographic X-ray computed tomography (PXCT), which can provide a 3D map of the complex-valued refractive index of the sample. The extension of PXCT to X-ray energies above 15 keV is challenging, but it can allow the imaging of object opaque to lower energy. We present here the implementation and developments of high-energy near- and far-field PXCT at the ESRF.

  10. Bessel beam fluorescence lifetime tomography of live embryos (Conference Presentation)

    Science.gov (United States)

    Xu, Dongli; Peng, Leilei

    2016-03-01

    Optical tomography allows isotropic 3D imaging of embryos. Scanning-laser optical tomography (SLOT) has superior light collecting efficiency than wide-field optical tomography, making it ideal for fluorescence imaging of live embryos. We previously reported an imaging system that combines SLOT with a novel Fourier-multiplexed fluorescence lifetime imaging (FmFLIM) technique named FmFLIM-SLOT. FmFLIM-SLOT performs multiplexed FLIM-FRET readout of multiple FRET sensors in live embryos. Here we report a recent effort on improving the spatial resolution of the FmFLIM-SLOT system in order to image complex biochemical processes in live embryos at the cellular level. Optical tomography has to compromise between resolution and the depth of view. In SLOT, the commonly-used focused Gaussian beam diverges quickly from the focal plane, making it impossible to achieve high resolution imaging in a large volume specimen. We thus introduce Bessel beam laser-scanning tomography, which illuminates the sample with a spatial-light-modulator-generated Bessel beam that has an extended focal depth. The Bessel beam is scanned across the whole specimen. Fluorescence projection images are acquired at equal angular intervals as the sample rotates. Reconstruction artifacts due to annular-rings of the Bessel beam are removed by a modified 3D filtered back projection algorithm. Furthermore, in combination of Fourier-multiplexing fluorescence lifetime imaging (FmFLIM) method, the Bessel FmFLIM-SLOT system is capable of perform 3D lifetime imaging of live embryos at cellular resolution. The system is applied to in-vivo imaging of transgenic Zebrafish embryos. Results prove that Bessel FmFLIM-SLOT is a promising imaging method in development biology research.

  11. Diffuse optical tomography for breast cancer imaging guided by computed tomography: A feasibility study.

    Science.gov (United States)

    Baikejiang, Reheman; Zhang, Wei; Li, Changqing

    2017-01-01

    Diffuse optical tomography (DOT) has attracted attentions in the last two decades due to its intrinsic sensitivity in imaging chromophores of tissues such as hemoglobin, water, and lipid. However, DOT has not been clinically accepted yet due to its low spatial resolution caused by strong optical scattering in tissues. Structural guidance provided by an anatomical imaging modality enhances the DOT imaging substantially. Here, we propose a computed tomography (CT) guided multispectral DOT imaging system for breast cancer imaging. To validate its feasibility, we have built a prototype DOT imaging system which consists of a laser at the wavelength of 650 nm and an electron multiplying charge coupled device (EMCCD) camera. We have validated the CT guided DOT reconstruction algorithms with numerical simulations and phantom experiments, in which different imaging setup parameters, such as projection number of measurements and width of measurement patch, have been investigated. Our results indicate that an air-cooling EMCCD camera is good enough for the transmission mode DOT imaging. We have also found that measurements at six angular projections are sufficient for DOT to reconstruct the optical targets with 2 and 4 times absorption contrast when the CT guidance is applied. Finally, we have described our future research plan on integration of a multispectral DOT imaging system into a breast CT scanner.

  12. Filter assessment applied to analytical reconstruction for industrial third-generation tomography

    Energy Technology Data Exchange (ETDEWEB)

    Velo, Alexandre F.; Martins, Joao F.T.; Oliveira, Adriano S.; Carvalho, Diego V.S.; Faria, Fernando S.; Hamada, Margarida M.; Mesquita, Carlos H., E-mail: afvelo@usp.br [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil)

    2015-07-01

    Multiphase systems are structures that contain a mixture of solids, liquids and gases inside a chemical reactor or pipes in a dynamic process. These systems are found in chemical, food, pharmaceutical and petrochemical industries. The gamma ray computed tomography (CT) system has been applied to visualize the distribution of multiphase systems without interrupting production. CT systems have been used to improve design, operation and troubleshooting of industrial processes. Computer tomography for multiphase processes is being developed at several laboratories. It is well known that scanning systems demand high processing time, limited set of data projections and views to obtain an image. Because of it, the image quality is dependent on the number of projection, number of detectors, acquisition time and reconstruction time. A phantom containing air, iron and aluminum was used on the third generation industrial tomography with 662 keV ({sup 137}Cs) radioactive source. It was applied the Filtered Back Projection algorithm to reconstruct the images. An efficient tomography is dependent of the image quality, thus the objective of this research was to apply different types of filters on the analytical algorithm and compare each other using the figure of merit denominated root mean squared error (RMSE), the filter that presents lower value of RMSE has better quality. On this research, five types of filters were used: Ram-Lak, Shepp-Logan, Cosine, Hamming and Hann filters. As results, all filters presented lower values of RMSE, that means the filters used have low stand deviation compared to the mass absorption coefficient, however, the Hann filter presented better RMSE and CNR compared to the others. (author)

  13. Filter assessment applied to analytical reconstruction for industrial third-generation tomography

    International Nuclear Information System (INIS)

    Velo, Alexandre F.; Martins, Joao F.T.; Oliveira, Adriano S.; Carvalho, Diego V.S.; Faria, Fernando S.; Hamada, Margarida M.; Mesquita, Carlos H.

    2015-01-01

    Multiphase systems are structures that contain a mixture of solids, liquids and gases inside a chemical reactor or pipes in a dynamic process. These systems are found in chemical, food, pharmaceutical and petrochemical industries. The gamma ray computed tomography (CT) system has been applied to visualize the distribution of multiphase systems without interrupting production. CT systems have been used to improve design, operation and troubleshooting of industrial processes. Computer tomography for multiphase processes is being developed at several laboratories. It is well known that scanning systems demand high processing time, limited set of data projections and views to obtain an image. Because of it, the image quality is dependent on the number of projection, number of detectors, acquisition time and reconstruction time. A phantom containing air, iron and aluminum was used on the third generation industrial tomography with 662 keV ( 137 Cs) radioactive source. It was applied the Filtered Back Projection algorithm to reconstruct the images. An efficient tomography is dependent of the image quality, thus the objective of this research was to apply different types of filters on the analytical algorithm and compare each other using the figure of merit denominated root mean squared error (RMSE), the filter that presents lower value of RMSE has better quality. On this research, five types of filters were used: Ram-Lak, Shepp-Logan, Cosine, Hamming and Hann filters. As results, all filters presented lower values of RMSE, that means the filters used have low stand deviation compared to the mass absorption coefficient, however, the Hann filter presented better RMSE and CNR compared to the others. (author)

  14. Comparison of two chemically-induced colitis-models in adult zebrafish, using optical projection tomography and novel transcriptional markers

    DEFF Research Database (Denmark)

    Haarder, Simon; Kania, Per Walter; Holm, Thomas

    2016-01-01

    , induced by the haptenizing agents oxazolone and TNBS. In addition, goblet cell dynamics in the scales and intestine and 5-HT (serotonin) in intestinal tissues were investigated through optical projection tomography. Gene expression studies revealed a distinct and significant upregulation...... of proinflammatory cytokines, acute-phase reactants and metalloprotease 9 in both chemical models, primarily after 72 hours. In comparison, transcription factors and cytokines associated with Th1 and Th17 (Crohn’s) and Th2 (ulcerative colitis) were mainly not affected in this acute setting. However, elevated...... transcript levels were detected in Foxp3, IL-10 and T-bet, which are linked with tolerance and Tregs in mammals. Goblet cells in scales were depleted in both chemical models and in the intestine of oxazolone-treated fish. A marked 5-HT signal was noted in intestinal tissue of some chemically treated...

  15. How to opt into the Common European Sales Law? Brief comments on the Commission's proposal for a regulation

    NARCIS (Netherlands)

    Hesselink, M.

    2012-01-01

    Unlike the actual text for the proposed Common European Sales Law (CESL), which is based on extensive preparatory work by academics, the regime for opting into the instrument, which is set out in the main text of the proposed regulation, is entirely of the European Commission's own making. The

  16. How to opt into the Common European Sales Law? Brief comments on the Commission's proposal for a regulation

    NARCIS (Netherlands)

    Hesselink, M.W.; Claeys, I.; Feltkamp, R.

    2013-01-01

    Unlike the actual text for the proposed Common European Sales Law (CESL), which is based on extensive preparatory work by academics, the regime for opting into the instrument, which is set out in the main text of the proposed regulation, is entirely of the European Commission's own making. The

  17. Algorithmic fundamentals of computerized tomography and of transverse analogue tomography

    International Nuclear Information System (INIS)

    Heckmann, K.

    1981-01-01

    Computerized tomography and transverse analogue tomography are two different approaches to the same goal, namely, transverse tomography. The algorithm is discussed and compared. Transverse tomography appears capable of further development, judging by this comparison. (orig.) [de

  18. Time Domain Terahertz Axial Computed Tomography Non Destructive Evaluation, Phase II

    Data.gov (United States)

    National Aeronautics and Space Administration — In this Phase 2 project, we propose to develop, construct, and deliver to NASA a computed axial tomography time-domain terahertz (CT TD-THz) non destructive...

  19. WE-G-BRF-05: Feasibility of Markerless Motion Tracking Using Dual Energy Cone Beam Computed Tomography (DE-CBCT) Projections

    International Nuclear Information System (INIS)

    Panfil, J; Patel, R; Surucu, M; Roeske, J

    2014-01-01

    Purpose: To compare markerless template-based tracking of lung tumors using dual energy (DE) cone-beam computed tomography (CBCT) projections versus single energy (SE) CBCT projections. Methods: A RANDO chest phantom with a simulated tumor in the upper right lung was used to investigate the effectiveness of tumor tracking using DE and SE CBCT projections. Planar kV projections from CBCT acquisitions were captured at 60 kVp (4 mAs) and 120 kVp (1 mAs) using the Varian TrueBeam and non-commercial iTools Capture software. Projections were taken at approximately every 0.53° while the gantry rotated. Due to limitations of the phantom, angles for which the shoulders blocked the tumor were excluded from tracking analysis. DE images were constructed using a weighted logarithmic subtraction that removed bony anatomy while preserving soft tissue structures. The tumors were tracked separately on DE and SE (120 kVp) images using a template-based tracking algorithm. The tracking results were compared to ground truth coordinates designated by a physician. Matches with a distance of greater than 3 mm from ground truth were designated as failing to track. Results: 363 frames were analyzed. The algorithm successfully tracked the tumor on 89.8% (326/363) of DE frames compared to 54.3% (197/363) of SE frames (p<0.0001). Average distance between tracking and ground truth coordinates was 1.27 +/− 0.67 mm for DE versus 1.83+/−0.74 mm for SE (p<0.0001). Conclusion: This study demonstrates the effectiveness of markerless template-based tracking using DE CBCT. DE imaging resulted in better detectability with more accurate localization on average versus SE. Supported by a grant from Varian Medical Systems

  20. Universal opt-out screening for hepatitis C virus (HCV) within correctional facilities is an effective intervention to improve public health.

    Science.gov (United States)

    Morris, Meghan D; Brown, Brandon; Allen, Scott A

    2017-09-11

    Purpose Worldwide efforts to identify individuals infected with the hepatitis C virus (HCV) focus almost exclusively on community healthcare systems, thereby failing to reach high-risk populations and those with poor access to primary care. In the USA, community-based HCV testing policies and guidelines overlook correctional facilities, where HCV rates are believed to be as high as 40 percent. This is a missed opportunity: more than ten million Americans move through correctional facilities each year. Herein, the purpose of this paper is to examine HCV testing practices in the US correctional system, California and describe how universal opt-out HCV testing could expand early HCV detection, improve public health in correctional facilities and communities, and prove cost-effective over time. Design/methodology/approach A commentary on the value of standardizing screening programs across facilities by mandating all facilities (universal) to implement opt-out testing policies for all prisoners upon entry to the correctional facilities. Findings Current variability in facility-level testing programs results in inconsistent testing levels across correctional facilities, and therefore makes estimating the actual number of HCV-infected adults in the USA difficult. The authors argue that universal opt-out testing policies ensure earlier diagnosis of HCV among a population most affected by the disease and is more cost-effective than selective testing policies. Originality/value The commentary explores the current limitations of selective testing policies in correctional systems and provides recommendations and implications for public health and correctional organizations.

  1. Illustrated computer tomography

    International Nuclear Information System (INIS)

    Takahashi, S.

    1983-01-01

    This book provides the following information: basic aspects of computed tomography; atlas of computed tomography of the normal adult; clinical application of computed tomography; and radiotherapy planning and computed tomography

  2. How Strong Is Europeanisation, Really? The Danish Defence Administration and the Opt-Out from the European Security and Defence Policy

    DEFF Research Database (Denmark)

    Olsen, Gorm Rye

    2011-01-01

    The article questions how strong Europeanisation is as an explanation of administrative changes in EU member states. Denmark has an opt-out from the European cooperation on defence, and, therefore, its defence administration represents a critical or a less likely case to test the Europeanisation...... thesis. The article shows that in spite of the opt-out, the administrative structures and the policy processes in the Ministry of Foreign Affairs (MFA) have adapted to the common foreign and security policy (CFSP) and the European security and defence policy (ESDP). Surprisingly, the administrative...... structures and the decision-making processes in the Ministry of Defence (MoD) have also adapted to the ESDP. The latter example emphasises the strength of top-down Europeanisation as a possible explanation of domestic administrative changes in member states. It is argued that Europeanisation per se...

  3. Emission Impacts of Electric Vehicles in the US Transportation Sector Following Optimistic Cost and Efficiency Projections.

    Science.gov (United States)

    Keshavarzmohammadian, Azadeh; Henze, Daven K; Milford, Jana B

    2017-06-20

    This study investigates emission impacts of introducing inexpensive and efficient electric vehicles into the US light duty vehicle (LDV) sector. Scenarios are explored using the ANSWER-MARKAL model with a modified version of the Environmental Protection Agency's (EPA) 9-region database. Modified cost and performance projections for LDV technologies are adapted from the National Research Council (2013) optimistic case. Under our optimistic scenario (OPT) we find 15% and 47% adoption of battery electric vehicles (BEVs) in 2030 and 2050, respectively. In contrast, gasoline vehicles (ICEVs) remain dominant through 2050 in the EPA reference case (BAU). Compared to BAU, OPT gives 16% and 36% reductions in LDV greenhouse gas (GHG) emissions for 2030 and 2050, respectively, corresponding to 5% and 9% reductions in economy-wide emissions. Total nitrogen oxides, volatile organic compounds, and SO 2 emissions are similar in the two scenarios due to intersectoral shifts. Moderate, economy-wide GHG fees have little effect on GHG emissions from the LDV sector but are more effective in the electricity sector. In the OPT scenario, estimated well-to-wheels GHG emissions from full-size BEVs with 100-mile range are 62 gCO 2 -e mi -1 in 2050, while those from full-size ICEVs are 121 gCO 2 -e mi -1 .

  4. eCodonOpt: a systematic computational framework for optimizing codon usage in directed evolution experiments

    OpenAIRE

    Moore, Gregory L.; Maranas, Costas D.

    2002-01-01

    We present a systematic computational framework, eCodonOpt, for designing parental DNA sequences for directed evolution experiments through codon usage optimization. Given a set of homologous parental proteins to be recombined at the DNA level, the optimal DNA sequences encoding these proteins are sought for a given diversity objective. We find that the free energy of annealing between the recombining DNA sequences is a much better descriptor of the extent of crossover formation than sequence...

  5. Quantitative inspection by computerized tomography

    International Nuclear Information System (INIS)

    Lopes, R.T.; Assis, J.T. de; Jesus, E.F.O. de

    1989-01-01

    The computerized Tomography (CT) is a method of nondestructive testing, that furnish quantitative information, that permit the detection and accurate localization of defects, internal dimension measurement, and, measurement and chart of the density distribution. The CT technology is much versatile, not presenting restriction in relation to form, size or composition of the object. A tomographic system, projected and constructed in our laboratory is presented. The applications and limitation of this system, illustrated by tomographyc images, are shown. (V.R.B.)

  6. Low-dose x-ray phase-contrast and absorption CT using equally sloped tomography

    International Nuclear Information System (INIS)

    Fahimian, Benjamin P; Miao Jianwei; Mao Yu; Cloetens, Peter

    2010-01-01

    Tomographic reconstruction from undersampled and noisy projections is often desirable in transmission CT modalities for purposes of low-dose tomography and fast acquisition imaging. However under such conditions, due to the violation of the Nyquist sampling criteria and the presence of noise, reconstructions with acceptable accuracy may not be possible. Recent experiments in transmission electron tomography and coherent diffraction microscopy have shown that the technique of equally sloped tomography (EST), an exact tomographic method utilizing an oversampling iterative Fourier-based reconstruction, provides more accurate image reconstructions when the number of projections is significantly undersampled relative to filtered back projection and algebraic iterative methods. Here we extend this technique by developing new reconstruction algorithms which allow for the incorporation of advanced mathematical regularization constraints, such as the nonlocal means total variational model, in a manner that is consistent with experimental projections. We then evaluate the resulting image quality of the developed algorithm through simulations and experiments at the European Synchrotron Radiation Facility on image quality phantoms using the x-ray absorption and phase contrast CT modalities. Both our simulation and experimental results have indicated that the method can reduce the number of projections by 60-75% in parallel beam modalities, while achieving comparable or better image quality than the conventional reconstructions. As large-scale and compact synchrotron radiation facilities are currently under rapid development worldwide, the implementation of low-dose x-ray absorption and phase-contrast CT can find broad applications in biology and medicine using these advanced x-ray sources.

  7. Implementation of a cone-beam reconstruction algorithm for the single-circle source orbit with embedded misalignment correction using homogeneous coordinates

    International Nuclear Information System (INIS)

    Karolczak, Marek; Schaller, Stefan; Engelke, Klaus; Lutz, Andreas; Taubenreuther, Ulrike; Wiesent, Karl; Kalender, Willi

    2001-01-01

    We present an efficient implementation of an approximate cone-beam image reconstruction algorithm for application in tomography, which accounts for scanner mechanical misalignment. The implementation is based on the algorithm proposed by Feldkamp et al. [J. Opt. Soc. Am. A 6, 612-619 (1984)] and is directed at circular scan paths. The algorithm has been developed for the purpose of reconstructing volume data from projections acquired in an experimental x-ray microtomography (μCT) scanner [Engelke et al., Der Radiologe 39, 203-212 (1999)]. To mathematically model misalignment we use matrix notation with homogeneous coordinates to describe the scanner geometry, its misalignment, and the acquisition process. For convenience analysis is carried out for x-ray CT scanners, but it is applicable to any tomographic modality, where two-dimensional projection acquisition in cone beam geometry takes place, e.g., single photon emission computerized tomography. We derive an algorithm assuming misalignment errors to be small enough to weight and filter original projections and to embed compensation for misalignment in the backprojection. We verify the algorithm on simulations of virtual phantoms and scans of a physical multidisk (Defrise) phantom

  8. Prediction of optimal deployment projection for transcatheter aortic valve replacement: angiographic 3-dimensional reconstruction of the aortic root versus multidetector computed tomography.

    Science.gov (United States)

    Binder, Ronald K; Leipsic, Jonathon; Wood, David; Moore, Teri; Toggweiler, Stefan; Willson, Alex; Gurvitch, Ronen; Freeman, Melanie; Webb, John G

    2012-04-01

    Identifying the optimal fluoroscopic projection of the aortic valve is important for successful transcatheter aortic valve replacement (TAVR). Various imaging modalities, including multidetector computed tomography (MDCT), have been proposed for prediction of the optimal deployment projection. We evaluated a method that provides 3-dimensional angiographic reconstructions (3DA) of the aortic root for prediction of the optimal deployment angle and compared it with MDCT. Forty patients undergoing transfemoral TAVR at St Paul's Hospital, Vancouver, Canada, were evaluated. All underwent preimplant 3DA and 68% underwent preimplant MDCT. Three-dimensional angiographic reconstructions were generated from images of a C-arm rotational aortic root angiogram during breath-hold, rapid ventricular pacing, and injection of 32 mL contrast medium at 8 mL/s. Two independent operators prospectively predicted perpendicular valve projections. The implant angle was chosen at the discretion of the physician performing TAVR. The angles from 3DA, from MDCT, the implant angle, and the postdeployment perpendicular prosthesis view were compared. The shortest distance from the postdeployment perpendicular prosthesis projection to the regression line of predicted perpendicular projections was calculated. All but 1 patient had adequate image quality for reproducible angle predictions. There was a significant correlation between 3DA and MDCT for prediction of perpendicular valve projections (r=0.682, Pregression line of predicted angles to the postdeployment prosthesis view was 5.1±4.6° for 3DA and 7.9±4.9° for MDCT (P=0.01). Three-dimensional angiographic reconstructions and MDCT are safe, practical, and accurate imaging modalities for identifying the optimal perpendicular valve deployment projection during TAVR.

  9. Turbocharging Quantum Tomography

    Energy Technology Data Exchange (ETDEWEB)

    Blume-Kohout, Robin J. [Sandia National Laboratories (SNL-NM), Albuquerque, NM (United States); Gamble, John King [Sandia National Laboratories (SNL-NM), Albuquerque, NM (United States); Nielsen, Erik [Sandia National Laboratories (SNL-NM), Albuquerque, NM (United States); Maunz, Peter Lukas Wilhelm [Sandia National Laboratories (SNL-NM), Albuquerque, NM (United States); Scholten, Travis L. [Sandia National Laboratories (SNL-NM), Albuquerque, NM (United States); Rudinger, Kenneth Michael [Sandia National Laboratories (SNL-NM), Albuquerque, NM (United States)

    2015-01-01

    Quantum tomography is used to characterize quantum operations implemented in quantum information processing (QIP) hardware. Traditionally, state tomography has been used to characterize the quantum state prepared in an initialization procedure, while quantum process tomography is used to characterize dynamical operations on a QIP system. As such, tomography is critical to the development of QIP hardware (since it is necessary both for debugging and validating as-built devices, and its results are used to influence the next generation of devices). But tomography suffers from several critical drawbacks. In this report, we present new research that resolves several of these flaws. We describe a new form of tomography called gate set tomography (GST), which unifies state and process tomography, avoids prior methods critical reliance on precalibrated operations that are not generally available, and can achieve unprecedented accuracies. We report on theory and experimental development of adaptive tomography protocols that achieve far higher fidelity in state reconstruction than non-adaptive methods. Finally, we present a new theoretical and experimental analysis of process tomography on multispin systems, and demonstrate how to more effectively detect and characterize quantum noise using carefully tailored ensembles of input states.

  10. Overview and outlook on muon survey tomography based on micromegas detectors for unreachable sites technology

    Directory of Open Access Journals (Sweden)

    Roche I. Lázaro

    2016-01-01

    Full Text Available The present document describes the functioning principles of the Muon Survey Tomography based on Micromegas detectors for Unreachable Sites Technology and its distinguishing features from other Micromegas-like detectors. Additionally, it addresses the challenges found while operating the first generation and the resulting improvements. Currently, the project Temporal Tomography of the Densitometry by the Measurement of Muons is focused on obtaining a reliable pulse from the micromesh, associated to the passing of a muon, in order to trigger the acquisition and operate in standalone mode. An outlook of the future steps of the project is provided as well.

  11. Joint project of the international network of agencies for health technology assessment--Part 1: Survey results on diffusion, assessment, and clinical use of positron emission tomography.

    Science.gov (United States)

    Hastings, John; Adams, Elizabeth J

    2006-01-01

    The International Network of Agencies for Health Technology Assessment (INAHTA) has been tracking activities associated with the clinical use of positron emission tomography (PET) in its members' healthcare systems since 1997 and published its first Joint Project report on PET in 1999. Part 1 of this Joint Project report presents survey results on diffusion, assessment activities, and policy for clinical use related to PET among INAHTA members since 1999. INAHTA members were surveyed in 2003-2004. Twenty-seven INAHTA agencies (69 percent response rate) from nineteen countries responded to the survey. Dedicated PET systems are the most universally installed systems to date. Mobile scanners and modified gamma cameras are used occasionally as lower cost alternatives, and interest in PET-computed tomography hybrid models is rising despite limited assessment of impact on service planning. PET was used and assessed most commonly for managing patients with cancer. All respondents reported having some form of public funding for clinical PET frequently linked to data collection for the purpose of gathering evidence to refine clinical use and guide resource allocation toward indications that maximize clinical and cost-effectiveness. The use of HTA within a continuous quality improvement framework can help optimize scarce resources for evaluation and use of high cost diagnostic technologies such as PET, particularly where potential clinical or cost-effectiveness is considerable but conclusive evidence is lacking.

  12. Review of tomography technique for 3-dimensional fission product distribution determination in irradiated fuel

    Energy Technology Data Exchange (ETDEWEB)

    Pakr, D G; Hong, K P; Joo, Y S; Lee, H K

    2006-04-15

    Tomography algorithm is reviewed in order to determine radial 2-dimensional fission product distribution of irradiated fuel rod and to reconstruct it's image using computer. Main contents are Radon transformation, Fourier central slice theorem, inverse Fourier transform, accompanied FBP(Filtered Back Projection) and BPB(Back Projection Filtering). In addition, another tomography reconstruction algorithm, namely, ART(Algebraic Reconstruction Technique) is reviewed briefly. According to reviewed results, we devise equipment for determining of 2-dimensional distribution of irradiated nuclear fuel using existing gamma scanning apparatus. On results of review, It is necessary to develop computer program of reconstruction algorithm for determining of object function and image reconstruction.

  13. Review of tomography technique for 3-dimensional fission product distribution determination in irradiated fuel

    International Nuclear Information System (INIS)

    Pakr, D. G.; Hong, K. P.; Joo, Y. S.; Lee, H. K.

    2006-04-01

    Tomography algorithm is reviewed in order to determine radial 2-dimensional fission product distribution of irradiated fuel rod and to reconstruct it's image using computer. Main contents are Radon transformation, Fourier central slice theorem, inverse Fourier transform, accompanied FBP(Filtered Back Projection) and BPB(Back Projection Filtering). In addition, another tomography reconstruction algorithm, namely, ART(Algebraic Reconstruction Technique) is reviewed briefly. According to reviewed results, we devise equipment for determining of 2-dimensional distribution of irradiated nuclear fuel using existing gamma scanning apparatus. On results of review, It is necessary to develop computer program of reconstruction algorithm for determining of object function and image reconstruction

  14. Minimum Fisher Tikhonov Regularization Adapted to Real-Time Tomography

    Czech Academy of Sciences Publication Activity Database

    Löffelmann, Viktor; Mlynář, Jan; Imríšek, Martin; Mazon, D.; Jardin, A.; Weinzettl, Vladimír; Hron, Martin

    2016-01-01

    Roč. 69, č. 2 (2016), s. 505-513 ISSN 1536-1055 R&D Projects: GA MŠk LG14002; GA MŠk(CZ) LM2011021 Institutional support: RVO:61389021 Keywords : tokamak * tomography * real - time Subject RIV: BL - Plasma and Gas Discharge Physics Impact factor: 0.578, year: 2016

  15. Optical tomography of tissues

    International Nuclear Information System (INIS)

    Zimnyakov, D A; Tuchin, Valerii V

    2002-01-01

    Methods of optical tomography of biological tissues are considered, which include pulse-modulation and frequency-modulation tomography, diffusion tomography with the use of cw radiation sources, optical coherent tomography, speckle-correlation tomography of nonstationary media, and optoacoustic tomography. The method for controlling the optical properties of tissues is studied from the point of view of increasing a probing depth in optical coherent tomography. The modern state and prospects of the development of optical tomography are discussed. (review)

  16. Compensation of some time dependent deformations in two dimensional (2D) tomography

    International Nuclear Information System (INIS)

    Desbat, L.; Roux, S.; Grangeat, P.

    2005-01-01

    This work is a contribution to motion compensation in tomography. It has been shown that much more general deformations than affine transforms can be analytically compensated in dynamic tomography. The class of deformations that transformed only a parallel projection geometry into an other parallel projection geometry, or a divergent projection geometry into an other divergent geometry have been considered. Among these deformation, it has been shown that those involving only an affine deformation along each line (this affine deformation can vary from line to line), can be efficiently analytically compensated, i e within a F.B.P. algorithm. This class of deformations is much larger than the very small class of affine deformation. It involves more local deformation possibilities. Deformations from this considered class have been written as a composition of an affine transform and deformations that can be compensated with weighting and re-binning step, the admissibility conditions and the F.B.P. algorithm are the same those given. (N.C.)

  17. Compensation of some time dependent deformations in two dimensional (2D) tomography

    Energy Technology Data Exchange (ETDEWEB)

    Desbat, L. [Universite Joseph Fourier, UMR CNRS 5525, 38 - Grenoble (France); Roux, S. [Universite Joseph Fourier, TIMC-IMAG, In3S, Faculte de Medecine, 38 - Grenoble (France)]|[CEA Grenoble, Lab. d' Electronique et de Technologie de l' Informatique (LETI), 38 (France); Grangeat, P. [CEA Grenoble, Lab. d' Electronique et de Technologie de l' Informatique (LETI), 38 (France)

    2005-07-01

    This work is a contribution to motion compensation in tomography. It has been shown that much more general deformations than affine transforms can be analytically compensated in dynamic tomography. The class of deformations that transformed only a parallel projection geometry into an other parallel projection geometry, or a divergent projection geometry into an other divergent geometry have been considered. Among these deformation, it has been shown that those involving only an affine deformation along each line (this affine deformation can vary from line to line), can be efficiently analytically compensated, i e within a F.B.P. algorithm. This class of deformations is much larger than the very small class of affine deformation. It involves more local deformation possibilities. Deformations from this considered class have been written as a composition of an affine transform and deformations that can be compensated with weighting and re-binning step, the admissibility conditions and the F.B.P. algorithm are the same those given. (N.C.)

  18. Adaptive multiresolution method for MAP reconstruction in electron tomography

    Energy Technology Data Exchange (ETDEWEB)

    Acar, Erman, E-mail: erman.acar@tut.fi [Department of Signal Processing, Tampere University of Technology, P.O. Box 553, FI-33101 Tampere (Finland); BioMediTech, Tampere University of Technology, Biokatu 10, 33520 Tampere (Finland); Peltonen, Sari; Ruotsalainen, Ulla [Department of Signal Processing, Tampere University of Technology, P.O. Box 553, FI-33101 Tampere (Finland); BioMediTech, Tampere University of Technology, Biokatu 10, 33520 Tampere (Finland)

    2016-11-15

    3D image reconstruction with electron tomography holds problems due to the severely limited range of projection angles and low signal to noise ratio of the acquired projection images. The maximum a posteriori (MAP) reconstruction methods have been successful in compensating for the missing information and suppressing noise with their intrinsic regularization techniques. There are two major problems in MAP reconstruction methods: (1) selection of the regularization parameter that controls the balance between the data fidelity and the prior information, and (2) long computation time. One aim of this study is to provide an adaptive solution to the regularization parameter selection problem without having additional knowledge about the imaging environment and the sample. The other aim is to realize the reconstruction using sequences of resolution levels to shorten the computation time. The reconstructions were analyzed in terms of accuracy and computational efficiency using a simulated biological phantom and publically available experimental datasets of electron tomography. The numerical and visual evaluations of the experiments show that the adaptive multiresolution method can provide more accurate results than the weighted back projection (WBP), simultaneous iterative reconstruction technique (SIRT), and sequential MAP expectation maximization (sMAPEM) method. The method is superior to sMAPEM also in terms of computation time and usability since it can reconstruct 3D images significantly faster without requiring any parameter to be set by the user. - Highlights: • An adaptive multiresolution reconstruction method is introduced for electron tomography. • The method provides more accurate results than the conventional reconstruction methods. • The missing wedge and noise problems can be compensated by the method efficiently.

  19. Non-linear time reversal ultrasonic pseudo-tomography

    Czech Academy of Sciences Publication Activity Database

    Převorovský, Zdeněk; Vejvodová, Šárka; Krofta, Josef; Převorovský, David

    2011-01-01

    Roč. 6, 3/4 (2011), s. 206-213 ISSN 1741-8410. [NDT in Progress. Praha, 05.11.2007-07.11.2007] R&D Projects: GA MPO(CZ) FR-TI1/274 Institutional research plan: CEZ:AV0Z20760514 Keywords : NDT * nonlinear elastic wave spectroscopy * time reversal mirrors * ultrasonic pseudo-tomography Subject RIV: BI - Acoustics http://www.inderscience.com/offer.php?id=43216

  20. 3D computed tomography using a microfocus X-ray source: Analysis of artifact formation in the reconstructed images using simulated as well as experimental projection data

    International Nuclear Information System (INIS)

    Krimmel, S.; Stephan, J.; Baumann, J.

    2005-01-01

    The scope of this contribution is to identify and to quantify the influence of different parameters on the formation of image artifacts in X-ray computed tomography (CT) resulting for example, from beam hardening or from partial lack of information using 3D cone beam CT. In general, the reconstructed image quality depends on a number of acquisition parameters concerning the X-ray source (e.g. X-ray spectrum), the geometrical setup (e.g. cone beam angle), the sample properties (e.g. absorption characteristics) and the detector properties. While it is difficult to distinguish the influence of different effects clearly in experimental projection data, they can be selected individually with the help of simulated projection data by varying the parameter set. The reconstruction of the 3D data set is performed with the filtered back projection algorithm according to Feldkamp, Davis and Kress for experimental as well as for simulated projection data. The experimental data are recorded with an industrial microfocus CT system which features a focal spot size of a few micrometers and uses a digital flat panel detector for data acquisition

  1. Multidetector computed tomography of the head in acute stroke: predictive value of different patterns of the dense artery sign revealed by maximum intensity projection reformations for location and extent of the infarcted area

    Energy Technology Data Exchange (ETDEWEB)

    Gadda, Davide; Vannucchi, Letizia; Niccolai, Franco; Neri, Anna T.; Carmignani, Luca; Pacini, Patrizio [Ospedale del Ceppo, U.O. Radiodiagnostica, Pistoia (Italy)

    2005-12-01

    Maximum intensity projections reconstructions from 2.5 mm unenhanced multidetector computed tomography axial slices were obtained from 49 patients within the first 6 h of anterior-circulation cerebral strokes to identify different patterns of the dense artery sign and their prognostic implications for location and extent of the infarcted areas. The dense artery sign was found in 67.3% of cases. Increased density of the whole M1 segment with extension to M2 of the middle cerebral artery was associated with a wider extension of cerebral infarcts in comparison to M1 segment alone or distal M1 and M2. A dense sylvian branch of the middle cerebral artery pattern was associated with a more restricted extension of infarct territory. We found 62.5% of patients without a demonstrable dense artery to have a limited peripheral cortical or capsulonuclear lesion. In patients with a 7-10 points on the Alberta Stroke Early Programme Computed Tomography Score and a dense proximal MCA in the first hours of ictus the mean decrease in the score between baseline and follow-up was 5.09{+-}1.92 points. In conclusion, maximum intensity projections from thin-slice images can be quickly obtained from standard computed tomography datasets using a multidetector scanner and are useful in identifying and correctly localizing the dense artery sign, with prognostic implications for the entity of cerebral damage. (orig.)

  2. Respiratory compensation in projection imaging using a magnification and displacement model

    International Nuclear Information System (INIS)

    Crawford, C.R.; King, K.F.; Ritchie, C.J.; Godwin, J.D.

    1996-01-01

    Respiratory motion during the collection of computed tomography (CT) projections generates structured artifacts and a loss of resolution that can render the scans unusable. This motion is problematic in scans of those patients who cannot suspend respiration, such as the very young or incubated patients. In this paper, the authors present an algorithm that can be used to reduce motion artifacts in CT scans caused by respiration. An approximate model for the effect of respiration is that the object cross section under interrogation experiences time-varying magnification and displacement along two axes. Using this model an exact filtered backprojection algorithm is derived for the case of parallel projections. The result is extended to generate an approximate reconstruction formula for fan-beam projections. Computer simulations and scans of phantoms on a commercial CT scanner validate the new reconstruction algorithms for parallel and fan-beam projections. Significant reduction in respiratory artifacts is demonstrated clinically when the motion model is satisfied. The method can be applied to projection data used in CT single photon emission computed tomography (SPECT), positron emission tomography (PET), and magnetic resonance imaging (MRI)

  3. Industrial Computed Tomography using Proximal Algorithm

    KAUST Repository

    Zang, Guangming

    2016-04-14

    In this thesis, we present ProxiSART, a flexible proximal framework for robust 3D cone beam tomographic reconstruction based on the Simultaneous Algebraic Reconstruction Technique (SART). We derive the proximal operator for the SART algorithm and use it for minimizing the data term in a proximal algorithm. We show the flexibility of the framework by plugging in different powerful regularizers, and show its robustness in achieving better reconstruction results in the presence of noise and using fewer projections. We compare our framework to state-of-the-art methods and existing popular software tomography reconstruction packages, on both synthetic and real datasets, and show superior reconstruction quality, especially from noisy data and a small number of projections.

  4. Digital Signal Processor for Data Transfer and Processing in MR Tomography

    Czech Academy of Sciences Publication Activity Database

    Smékal, Z.; Gescheidtová, E.; Bartušek, Karel; Dokoupil, Zdeněk

    2005-01-01

    Roč. 13, č. 1 (2005), s. 39-48 ISSN 1738-6438 R&D Projects: GA AV ČR(CZ) IAA2065201 Keywords : MR tomography * DSP96002 * preemphasis filter * communication interface Subject RIV: JA - Electronics ; Optoelectronics, Electrical Engineering

  5. Optimizing Cofactor Specificity of Oxidoreductase Enzymes for the Generation of Microbial Production Strains—OptSwap

    DEFF Research Database (Denmark)

    King, Zachary A.; Feist, Adam

    2013-01-01

    Central oxidoreductase enzymes (eg, dehydrogenases, reductases) in microbial metabolism often have preferential binding specificity for one of the two major currency metabolites NAD(H) and NADP(H). These enzyme specificities result in a division of the metabolic functionality of the currency...... specificities of oxidoreductase enzyme and complementary reaction knockouts. Using the Escherichia coli genome-scale metabolic model iJO1366, OptSwap predicted eight growth-coupled production designs with significantly greater product yields or substrate-specific productivities than designs predicted with gene...

  6. Virtual reality boosts performance at AREVA Projects

    International Nuclear Information System (INIS)

    Bernasconi, F.

    2017-01-01

    AREVA Projects is one of the 6 business units of New AREVA and it is dedicated to engineering works in a vast fan of activities from mining to waste management via uranium chemistry and nuclear fuel recycling. AREVA projects has opted for innovation to improve performance. Since 2012 virtual reality has been used through the creation of a room equipped with a high-definition screen and stereoscopic goggles. At the beginning virtual reality was used to test and validate procedures for handling equipment thanks to a dynamical digital simulation of this equipment. Now virtual reality is massively used to validate the design phase of projects without having to fabricate a physical mock-up which saves time. The next step in the use of virtual reality is the implementation of a new version of devices like helmets, gloves... that will allow a better interaction with the virtual world. The continuously increasing of computer power is always pushing back the limits of what is possible in virtual reality. (A.C.)

  7. Distributed Kalman filtering compared to Fourier domain preconditioned conjugate gradient for laser guide star tomography on extremely large telescopes.

    Science.gov (United States)

    Gilles, Luc; Massioni, Paolo; Kulcsár, Caroline; Raynaud, Henri-François; Ellerbroek, Brent

    2013-05-01

    This paper discusses the performance and cost of two computationally efficient Fourier-based tomographic wavefront reconstruction algorithms for wide-field laser guide star (LGS) adaptive optics (AO). The first algorithm is the iterative Fourier domain preconditioned conjugate gradient (FDPCG) algorithm developed by Yang et al. [Appl. Opt.45, 5281 (2006)], combined with pseudo-open-loop control (POLC). FDPCG's computational cost is proportional to N log(N), where N denotes the dimensionality of the tomography problem. The second algorithm is the distributed Kalman filter (DKF) developed by Massioni et al. [J. Opt. Soc. Am. A28, 2298 (2011)], which is a noniterative spatially invariant controller. When implemented in the Fourier domain, DKF's cost is also proportional to N log(N). Both algorithms are capable of estimating spatial frequency components of the residual phase beyond the wavefront sensor (WFS) cutoff frequency thanks to regularization, thereby reducing WFS spatial aliasing at the expense of more computations. We present performance and cost analyses for the LGS multiconjugate AO system under design for the Thirty Meter Telescope, as well as DKF's sensitivity to uncertainties in wind profile prior information. We found that, provided the wind profile is known to better than 10% wind speed accuracy and 20 deg wind direction accuracy, DKF, despite its spatial invariance assumptions, delivers a significantly reduced wavefront error compared to the static FDPCG minimum variance estimator combined with POLC. Due to its nonsequential nature and high degree of parallelism, DKF is particularly well suited for real-time implementation on inexpensive off-the-shelf graphics processing units.

  8. HAADF-STEM atom counting in atom probe tomography specimens: Towards quantitative correlative microscopy.

    Science.gov (United States)

    Lefebvre, W; Hernandez-Maldonado, D; Moyon, F; Cuvilly, F; Vaudolon, C; Shinde, D; Vurpillot, F

    2015-12-01

    The geometry of atom probe tomography tips strongly differs from standard scanning transmission electron microscopy foils. Whereas the later are rather flat and thin (atom probe tomography specimens. Based on simulations (electron probe propagation and image simulations), the possibility to apply quantitative high angle annular dark field scanning transmission electron microscopy to of atom probe tomography specimens has been tested. The influence of electron probe convergence and the benefice of deconvolution of electron probe point spread function electron have been established. Atom counting in atom probe tomography specimens is for the first time reported in this present work. It is demonstrated that, based on single projections of high angle annular dark field imaging, significant quantitative information can be used as additional input for refining the data obtained by correlative analysis of the specimen in APT, therefore opening new perspectives in the field of atomic scale tomography. Copyright © 2015 Elsevier B.V. All rights reserved.

  9. Computerized tomography

    International Nuclear Information System (INIS)

    Rubashov, I.B.

    1985-01-01

    Operating principle is described for the devices of computerized tomography used in medicine for diagnosis of brain diseases. Computerized tomography is considered as a part of computerized diagnosis, as a part of information science. It is shown that computerized tomography is a real existed field of investigations in medicine and industrial production

  10. [Dome-shaped macula: appearance on ultrasound and optical coherence tomography].

    Science.gov (United States)

    Chéour, M; Ben Aleya, N; Brour, J; Falfoul, Y; Agrebi, S; Skhiri, M; Kraïem, A

    2013-10-01

    The purpose of our work is to demonstrate the role of optical coherence tomography and ocular ultrasound in the diagnosis of the dome-shaped macula in high myopia. We report the case of a patient with high myopia who presented with a decrease in visual acuity and metamorphopsia in the left eye. She underwent visual acuity measurement, biomicroscopic examination and measurement of axial length. B-mode ultrasound and optical coherence tomography showed a projection of the macula in the convexity of the myopic staphyloma confirming the diagnosis of dome-shaped macula. Dome-shaped macula is a recently discovered entity, which may be responsible for a decrease in visual acuity in patients with high myopic posterior staphyloma. Ultrasound and optical coherence tomography are very helpful in making the diagnosis. Copyright © 2013. Published by Elsevier Masson SAS.

  11. X-ray microtome by fluorescence tomography

    CERN Document Server

    Simionovici, A S; Guenzler, F; Schrör, C; Snigirev, A; Snigireva, I; Tümmler, J; Weitkamp, T

    2001-01-01

    The X-ray fluorescence microtomography method is presented, which is capable of virtually slicing samples to obtain cross-sections of their inner structure. High precision experimental results of fluo-tomography in 'pencil-beam' geometry with up to 1.2 mu m resolution are described. Image reconstructions are based on either a simplified algebraic reconstruction method (ART) or the filtered back-projection method (FBP). Phantoms of inhomogeneous test objects as well as biological samples are successfully analyzed.

  12. Absorbed and effective dose from spiral and computed tomography for the dental implant planning

    International Nuclear Information System (INIS)

    Hong, Beong Hee; Han, Won Jeong; Kim, Eun Kyung

    2001-01-01

    To evaluate the absorbed and effective doses of spiral and computed tomography for the dental implant planning. For radiographic projection. TLD chips were placed in 22 sites of humanoid phantom to record the exposure to skin and the mean absorbed dose to bone marrow, thyroid, pituitary, parotid and submandibular glands and nesophages. Effective dose was calculated, using the method suggested by Frederiksen at al.. Patient situations of a single tooth gap in upper and lower midline region, edentulous maxilla and mandible were simulated for spiral tomography. 35 axial slices (maxilla) and 40 axial slices (mandible) with low and standard dose setting were used for computed tomography. All the radiographic procedures were repeated three times. The mean effective dose in case of maxilla was 0.865 mSv, 0.452 mSv, 0.136 mSv and 0.025 mSv, in spiral tomography of complete edentulous maxilla, computed tomography with standard mAs, computed tomography with low mAs and spiral tomography of a single tooth gap (p<0.05). That in case of mandible was 0.614 mSv, 0.448 mSv, 0.137 mSv and 0.036 mSv, in spiral tomography of complete edentulous mandible, computed tomography with standard mAs, computed tomography with low mAs and spiral tomography of a single tooth gap (p<0.05). Based on these results, it can be concluded that low mAs computed tomography is recommended instead of spiral tomography for the complete edentulous maxilla and mandible dental implant treatment planning

  13. Waste Inspection Tomography for Non-Destructive Evaluation (WITNDA)

    International Nuclear Information System (INIS)

    Ramar, R.; Priyada, P.; Shivaramu; Venkatraman, B.

    2012-01-01

    A gamma ray Computed Tomography (CT) system developed indigenously for doing feasibility studies on tomographic waste assay and for validating the transmission and emission tomography algorithms. Automation of the data collection has been achieved by integrating four axes Galil based drum rotating driver and HPGe gamma spectroscopy software using windows based Visual Basic (VB) program. Attenuation tomograms using Filter Back Projection (FBP) and Algebraic Reconstruction Technique (ART) and emission tomograms using Maximum Likelihood Expectation Maximization (MLEM) techniques developed and validated. The transmission tomograms of a MS test object of 165 mm OD cylindrical container with MS rods and filled with sand and emission tomograms of a 4.7 mCi 137 Cs source embedded in the test object and its activity quantified. (author)

  14. System Matrix Analysis for Computed Tomography Imaging

    Science.gov (United States)

    Flores, Liubov; Vidal, Vicent; Verdú, Gumersindo

    2015-01-01

    In practical applications of computed tomography imaging (CT), it is often the case that the set of projection data is incomplete owing to the physical conditions of the data acquisition process. On the other hand, the high radiation dose imposed on patients is also undesired. These issues demand that high quality CT images can be reconstructed from limited projection data. For this reason, iterative methods of image reconstruction have become a topic of increased research interest. Several algorithms have been proposed for few-view CT. We consider that the accurate solution of the reconstruction problem also depends on the system matrix that simulates the scanning process. In this work, we analyze the application of the Siddon method to generate elements of the matrix and we present results based on real projection data. PMID:26575482

  15. MIT Project Apophis: Surface Evaulation & Tomography (SET) Mission Study for the April 2029 Earth Encounter

    Science.gov (United States)

    Binzel, R. P.; Earle, A. M.; Vanatta, M.; Miller, D. W.

    2017-12-01

    Nature is providing a once-per-thousand year opportunity to study the geophysical outcome induced on an unprecedentedly large (350 meter) asteroid making an extremely close passage by the Earth (inside the distance of geosynchronous satellites) on Friday April 13, 2029. The aircraft carrier-sized (estimated 20 million metric ton) asteroid is named Apophis. While many previous spacecraft missions have studied asteroids, none has ever had the opportunity to study "live" the outcome of planetary tidal forces on their shapes, spin states, surface geology, and internal structure. Beyond the science interest directly observing this planetary process, the Apophis encounter provides an invaluable opportunity to gain knowledge for any eventuality of a known asteroid found to be on a certain impact trajectory. MIT's Project Apophis [1] is our response to nature's generous opportunity by developing a detailed mission concept for sending a spacecraft to orbit Apophis with the objectives of surveying its surface and interior structure before, during, and after its 2029 near-Earth encounter. The Surface Evaluation & Tomography (SET) mission concept we present is designed toward accomplishing three key science objectives: (1) bulk physical characterization, (2) internal structure, and (3) long-term orbit tracking. For its first mission objective, SET will study Apophis' bulk properties, including: shape, size, mass, volume, bulk density, surface geology, and composition, rotation rate, and spin state. The second mission objective is to characterize Apophis' internal structure before and after the encounter to determine its strength and cohesion - including tidally induced changes. Finally, the third objective studies the process of thermal re-radiation and consequential Yarkovsky drift, whose results will improve orbit predictions for Apophis as well as other potentially hazardous asteroids. [1] https://eapsweb.mit.edu/mit-project-apophis

  16. Dynamic angle selection in X-ray computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Dabravolski, Andrei, E-mail: andrei.dabravolski@uantwerpen.be [iMinds-Vision Lab, University of Antwerp, Universiteitsplein 1, 2610 Wilrijk (Belgium); Batenburg, Kees Joost, E-mail: joost.batenburg@uantwerpen.be [iMinds-Vision Lab, University of Antwerp, Universiteitsplein 1, 2610 Wilrijk (Belgium); Centrum Wiskunde and Informatica (CWI), Science Park 123, 1098 XG Amsterdam (Netherlands); Sijbers, Jan, E-mail: jan.sijbers@uantwerpen.be [iMinds-Vision Lab, University of Antwerp, Universiteitsplein 1, 2610 Wilrijk (Belgium)

    2014-04-01

    Highlights: • We propose the dynamic angle selection algorithm for CT scanning. • The approach is based on the concept of information gain over a set of solutions. • Projection angles are selected based on the already available projection data. • The approach can lead to more accurate results from fewer projections. - Abstract: In X-ray tomography, a number of radiographs (projections) are recorded from which a tomogram is then reconstructed. Conventionally, these projections are acquired equiangularly, resulting in an unbiased sampling of the Radon space. However, especially in case when only a limited number of projections can be acquired, the selection of the angles has a large impact on the quality of the reconstructed image. In this paper, a dynamic algorithm is proposed, in which new projection angles are selected by maximizing the information gain about the object, given the set of possible new angles. Experiments show that this approach can select projection angles for which the accuracy of the reconstructed image is significantly higher compared to the standard angle selections schemes.

  17. Dynamic angle selection in X-ray computed tomography

    International Nuclear Information System (INIS)

    Dabravolski, Andrei; Batenburg, Kees Joost; Sijbers, Jan

    2014-01-01

    Highlights: • We propose the dynamic angle selection algorithm for CT scanning. • The approach is based on the concept of information gain over a set of solutions. • Projection angles are selected based on the already available projection data. • The approach can lead to more accurate results from fewer projections. - Abstract: In X-ray tomography, a number of radiographs (projections) are recorded from which a tomogram is then reconstructed. Conventionally, these projections are acquired equiangularly, resulting in an unbiased sampling of the Radon space. However, especially in case when only a limited number of projections can be acquired, the selection of the angles has a large impact on the quality of the reconstructed image. In this paper, a dynamic algorithm is proposed, in which new projection angles are selected by maximizing the information gain about the object, given the set of possible new angles. Experiments show that this approach can select projection angles for which the accuracy of the reconstructed image is significantly higher compared to the standard angle selections schemes

  18. Tomography system having an ultrahigh speed processing unit

    International Nuclear Information System (INIS)

    Cox, J.P. Jr.; Gerth, V.W. Jr.

    1977-01-01

    A transverse section tomography system has an ultrahigh-speed data processing unit for performing back projection and updating. An x-ray scanner directs x-ray beams through a planar section of a subject from a sequence of orientations and positions. The scanner includes a movably supported radiation detector for detecting the intensity of the beams of radiation after they pass through the subject

  19. First results of micro-neutron tomography by use of a focussing neutron lens

    CERN Document Server

    Masschaele, B; Cauwels, P; Dierick, M; Jolie, J; Mondelaers, W

    2001-01-01

    Since the appearance of high flux neutron beams, scientists experimented with neutron radiography. This high beam flux combined with modern neutron to visible light converters leads to the possibility of performing fast neutron micro-tomography. The first results of cold neutron tomography with a neutron lens are presented in this article. Samples are rotated in the beam and the projections are recorded with a neutron camera. The 3D reconstruction is performed with cone beam reconstruction software.

  20. Differential Bees Flux Balance Analysis with OptKnock for in silico microbial strains optimization.

    Directory of Open Access Journals (Sweden)

    Yee Wen Choon

    Full Text Available Microbial strains optimization for the overproduction of desired phenotype has been a popular topic in recent years. The strains can be optimized through several techniques in the field of genetic engineering. Gene knockout is a genetic engineering technique that can engineer the metabolism of microbial cells with the objective to obtain desirable phenotypes. However, the complexities of the metabolic networks have made the process to identify the effects of genetic modification on the desirable phenotypes challenging. Furthermore, a vast number of reactions in cellular metabolism often lead to the combinatorial problem in obtaining optimal gene deletion strategy. Basically, the size of a genome-scale metabolic model is usually large. As the size of the problem increases, the computation time increases exponentially. In this paper, we propose Differential Bees Flux Balance Analysis (DBFBA with OptKnock to identify optimal gene knockout strategies for maximizing the production yield of desired phenotypes while sustaining the growth rate. This proposed method functions by improving the performance of a hybrid of Bees Algorithm and Flux Balance Analysis (BAFBA by hybridizing Differential Evolution (DE algorithm into neighborhood searching strategy of BAFBA. In addition, DBFBA is integrated with OptKnock to validate the results for improving the reliability the work. Through several experiments conducted on Escherichia coli, Bacillus subtilis, and Clostridium thermocellum as the model organisms, DBFBA has shown a better performance in terms of computational time, stability, growth rate, and production yield of desired phenotypes compared to the methods used in previous works.

  1. Is 'Opt-Out HIV Testing' a real option among pregnant women in rural districts in Kenya?

    Directory of Open Access Journals (Sweden)

    Wamalwa David

    2011-03-01

    Full Text Available Abstract Background An 'opt-out' policy of routine HIV counseling and testing (HCT is being implemented across sub-Saharan Africa to expand prevention of mother-to-child transmission (PMTCT. Although the underlying assumption is that pregnant women in rural Africa are able to voluntarily consent to HIV testing, little is known about the reality and whether 'opt-out' HCT leads to higher completion rates of PMTCT. Factors associated with consent to HIV testing under the 'opt-out' approach were investigated through a large cross-sectional study in Kenya. Methods Observations during HIV pre-test information sessions were followed by a cross-sectional survey of 900 pregnant women in three public district hospitals carrying out PMTCT in the Busia district. Women on their first antenatal care (ANC visit during the current pregnancy were interviewed after giving blood for HIV testing but before learning their test results. Descriptive statistics and multivariate regression analysis were performed. Results Of the 900 women participating, 97% tested for HIV. Lack of testing kits was the only reason for women not being tested, i.e. nobody declined HIV testing. Despite the fact that 96% had more than four earlier pregnancies and 37% had been tested for HIV at ANC previously, only 17% of the women surveyed knew that testing was optional. Only 20% of those surveyed felt they could make an informed decision to decline HIV testing. Making an informed decision to decline HIV testing was associated with knowing that testing was optional (OR = 5.44, 95%CI 3.44-8.59, not having a stable relationship with the child's father (OR = 1.76, 95%CI 1.02-3.03, and not having discussed HIV testing with a partner before the ANC visit (OR = 2.64 95%CI 1.79-3.86. Conclusion High coverage of HIV testing appears to be achieved at the cost of pregnant women not understanding that testing is optional. Good quality HIV pre-test information is central to ensure that pregnant women

  2. Domestic uptake of green energy promoted by opt-out tariffs

    Science.gov (United States)

    Ebeling, Felix; Lotz, Sebastian

    2015-09-01

    Motivating individuals to choose energy from sustainable sources over conventionally produced power constitutes one of the biggest policy challenges for societies. Here we present the results of a randomized controlled trial in Germany that tested the impact of default rules (that is, a type of `nudging’) on voluntary purchases of `green’ energy contracts that entirely stem from renewable resources. Setting the default choice to more expensive `green’ energy (that is, where consumers have to actively opt out if they do not want it) increased purchases of such nearly tenfold. Furthermore, county-level political preference for the green party uniquely predicted behaviour in the absence of the nudge, suggesting that default setting potentially overrules motivational aspects of green energy purchases. In follow-up experiments, we provide further evidence that the effect does not seem to be driven by unawareness. Summarizing, the present research provides an example of using behavioural science for climate change mitigation and shows alternatives to the use of subsidies or other economic incentives.

  3. Opt-Out Panel Testing for HIV, Hepatitis B and Hepatitis C in an Urban Emergency Department: A Pilot Study.

    Directory of Open Access Journals (Sweden)

    Sarah O'Connell

    Full Text Available Studies suggest 2 per 1000 people in Dublin are living with HIV, the level above which universal screening is advised. We aimed to assess the feasibility and acceptability of a universal opt-out HIV, Hepatitis B and Hepatitis C testing programme for Emergency Department patients and to describe the incidence and prevalence of blood-borne viruses in this population.An opt-out ED blood borne virus screening programme was piloted from March 2014 to January 2015. Patients undergoing blood sampling during routine clinical care were offered HIV 1&2 antibody/antigen assay, HBV surface antigen and HCV antibody tests. Linkage to care where necessary was co-ordinated by the study team. New diagnosis and prevalence rates were defined as the new cases per 1000 tested and number of positive tests per 1000 tested respectively.Over 45 weeks of testing, of 10,000 patient visits, 8,839 individual patient samples were available for analysis following removal of duplicates. A sustained target uptake of >50% was obtained after week 3. 97(1.09%, 44(0.49% and 447(5.05% HIV, Hepatitis B and Hepatitis C tests were positive respectively. Of these, 7(0.08%, 20(0.22% and 58(0.66% were new diagnoses of HIV, Hepatitis B and Hepatitis C respectively. The new diagnosis rate for HIV, Hepatitis B and Hepatitis C was 0.8, 2.26 and 6.5 per 1000 and study prevalence for HIV, Hepatitis B and Hepatitis C was 11.0, 5.0 and 50.5 per 1000 respectively.Opt-out blood borne viral screening was feasible and acceptable in an inner-city ED. Blood borne viral infections were prevalent in this population and newly diagnosed cases were diagnosed and linked to care. These results suggest widespread blood borne viral testing in differing clinical locations with differing population demographic risks may be warranted.

  4. Computerized tomography used in non-destructive testing of welded pipes

    Energy Technology Data Exchange (ETDEWEB)

    Iovea, M; Rizescu, C; Georgescu, G; Marinescu, A; Chitescu, P; Sava, T; Neagu, M; Avram, D [Institute of Research and Design for Electrical Engineering, ICPE - Electrostatica Splaiul Unirii 313, Sect. 3, R-74204 Bucharest (Romania)

    1997-12-31

    High quality standards in operation of National Power System is ensured by the use of high performance techniques and systems for Non-Destructive Testing (NDT). In recent years a number of new developments of the non-conventional technologies in the field of NDT have been achieved. In our laboratory there have been developed two computerized technologies using {gamma}-ray computed tomography and ultrasonic imaging methods. The standard techniques for imaging from projection data is computerized tomography. The industrial computerized tomography methods consist in the measurement of thin X - or {gamma}-ray beam attenuation when passing through some selected surface of the tested object, along several directions, so that by means of an adequate mathematical algorithm, a map of linear attenuation coefficients for the scanned surface is obtained. In fact, this map gives the density of materials occurring in the surface plane. Computerized tomography equipment, in various constructive versions, are intended for the following applications: (1) NDT in those fields requiring strict control of product quality, as for instance the nuclear energy, military industry, aeronautics, transportation fields, etc., (2) research in field of materials technology, machine engineering, metallurgy, welding, etc. This paper presents the applications of Computerized Tomography in NDT, by showing the results obtained on welded pipes, as well as the facilities offered by this method. In the final part, the paper presents the concept of a mobile tomography system for industrial pipes testing. (author). 2 figs., 7 refs.

  5. Computerized tomography used in non-destructive testing of welded pipes

    International Nuclear Information System (INIS)

    Iovea, M.; Rizescu, C.; Georgescu, G.; Marinescu, A.; Chitescu, P.; Sava, T.; Neagu, M.; Avram, D.

    1996-01-01

    High quality standards in operation of National Power System is ensured by the use of high performance techniques and systems for Non-Destructive Testing (NDT). In recent years a number of new developments of the non-conventional technologies in the field of NDT have been achieved. In our laboratory there have been developed two computerized technologies using γ-ray computed tomography and ultrasonic imaging methods. The standard techniques for imaging from projection data is computerized tomography. The industrial computerized tomography methods consist in the measurement of thin X - or γ-ray beam attenuation when passing through some selected surface of the tested object, along several directions, so that by means of an adequate mathematical algorithm, a map of linear attenuation coefficients for the scanned surface is obtained. In fact, this map gives the density of materials occurring in the surface plane. Computerized tomography equipment, in various constructive versions, are intended for the following applications: 1) NDT in those fields requiring strict control of product quality, as for instance the nuclear energy, military industry, aeronautics, transportation fields, etc., 2) research in field of materials technology, machine engineering, metallurgy, welding, etc. This paper presents the applications of Computerized Tomography in NDT, by showing the results obtained on welded pipes, as well as the facilities offered by this method. In the final part, the paper presents the concept of a mobile tomography system for industrial pipes testing. (author). 2 figs., 7 refs

  6. Registration-based Reconstruction of Four-dimensional Cone Beam Computed Tomography

    DEFF Research Database (Denmark)

    Christoffersen, Christian; Hansen, David Christoffer; Poulsen, Per Rugaard

    2013-01-01

    We present a new method for reconstruction of four-dimensional (4D) cone beam computed tomography from an undersampled set of X-ray projections. The novelty of the proposed method lies in utilizing optical flow based registration to facilitate that each temporal phase is reconstructed from the full...

  7. RELIABILITY OF POSITRON EMISSION TOMOGRAPHY-COMPUTED TOMOGRAPHY IN EVALUATION OF TESTICULAR CARCINOMA PATIENTS.

    Science.gov (United States)

    Nikoletić, Katarina; Mihailović, Jasna; Matovina, Emil; Žeravica, Radmila; Srbovan, Dolores

    2015-01-01

    The study was aimed at assessing the reliability of 18F-fluorodeoxyglucose positron emission tomography-computed tomography scan in evaluation of testicular carcinoma patients. The study sample consisted of 26 scans performed in 23 patients with testicular carcinoma. According to the pathohistological finding, 14 patients had seminomas, 7 had nonseminomas and 2 patients had a mixed histological type. In 17 patients, the initial treatment was orchiectomy+chemotherapy, 2 patients had orchiectomy+chemotherapy+retroperitoneal lymph node dissection, 3 patients had orchiectomy only and one patient was treated with chemotherapy only. Abnormal computed tomography was the main cause for the oncologist to refer the patient to positron emission tomography-computed tomography scan (in 19 scans), magnetic resonance imaging abnormalities in 1 scan, high level oftumor markers in 3 and 3 scans were perforned for follow-up. Positron emission tomography-computed tomography imaging results were compared with histological results, other imaging modalities or the clinical follow-up of the patients. Positron emission tomography-computed tomography scans were positive in 6 and negative in 20 patients. In two patients, positron emission tomography-computed tomography was false positive. There were 20 negative positron emission omography-computed tomography scans perforned in 18 patients, one patient was lost for data analysis. Clinically stable disease was confirmed in 18 follow-up scans performed in 16 patients. The values of sensitivty, specificity, accuracy, and positive- and negative predictive value were 60%, 95%, 75%, 88% and 90.5%, respectively. A hgh negative predictive value obtained in our study (90.5%) suggests that there is a small possibility for a patient to have future relapse after normal positron emission tomography-computed tomography study. However, since the sensitivity and positive predictive value of the study ire rather low, there are limitations of positive

  8. Evolution of the GATE project: new results and developments

    Energy Technology Data Exchange (ETDEWEB)

    Santin, G. [ESA-ESTEC, Keplerlaan 1, 2200 AG Noordwijk (Netherlands); Staelens, S. [ELIS Department, Ghent University, B-9000 Ghent (Belgium); Taschereau, R. [CRUMP Institute for Molecular Imaging, University of California Los Angeles, 700 Westwood Plaza A438, Los Angeles, CA 90095-1770 (United States); Descourt, P. [U650 INSERM, LaTIM, Brest (France); Schmidtlein, C.R. [Memorial Sloan-Kettering Cancer Center, New York, New York, US (United States); Simon, L. [Department of Radiation Oncology, Institut Curie, Paris (France); Visvikis, D. [U650 INSERM, LaTIM, Brest (France); Jan, S. [Service Hospitalier Frederic Joliot (SHFJ), CEA-Orsay, Orsay (France); Buvat, I. [U678 INSERM, CHU Pitie-Salpetriere, Paris (France)

    2007-10-15

    We present the status of the Geant4 Application for Emission Tomography (GATE) project, a Monte Carlo simulator for Single Photon Emission Computed Tomography (SPECT) and Positron annihilation Emission Tomography (PET). Its main features are reminded, including modelling of time dependent phenomena and versatile, user-friendly scripting interface. The focus of this manuscript will be on new developments introduced in the past 4 years. New results have been achieved in the fields of validation on real medical and research PET and SPECT systems, voxel geometries, digitisation, distributed computing and dosimetry.

  9. Evolution of the GATE project: new results and developments

    International Nuclear Information System (INIS)

    Santin, G.; Staelens, S.; Taschereau, R.; Descourt, P.; Schmidtlein, C.R.; Simon, L.; Visvikis, D.; Jan, S.; Buvat, I.

    2007-01-01

    We present the status of the Geant4 Application for Emission Tomography (GATE) project, a Monte Carlo simulator for Single Photon Emission Computed Tomography (SPECT) and Positron annihilation Emission Tomography (PET). Its main features are reminded, including modelling of time dependent phenomena and versatile, user-friendly scripting interface. The focus of this manuscript will be on new developments introduced in the past 4 years. New results have been achieved in the fields of validation on real medical and research PET and SPECT systems, voxel geometries, digitisation, distributed computing and dosimetry

  10. Opt-Out Panel Testing for HIV, Hepatitis B and Hepatitis C in an Urban Emergency Department: A Pilot Study.

    LENUS (Irish Health Repository)

    O'Connell, Sarah

    2016-01-01

    Studies suggest 2 per 1000 people in Dublin are living with HIV, the level above which universal screening is advised. We aimed to assess the feasibility and acceptability of a universal opt-out HIV, Hepatitis B and Hepatitis C testing programme for Emergency Department patients and to describe the incidence and prevalence of blood-borne viruses in this population.

  11. Tomography

    International Nuclear Information System (INIS)

    1985-01-01

    Already widely accepted in medicine, tomography can also be useful in industry. The theory behind tomography and a demonstration of the technique to inspect a motorcycle carburetor is presented. To demonstrate the potential of computer assisted tomography (CAT) to accurately locate defects in three dimensions, a sectioned 5 cm gate valve with a shrink cavity made visible by the sectioning was tomographically imaged using a Co-60 source. The tomographic images revealed a larger cavity below the sectioned surface. The position of this cavity was located with an in-plane and axial precision of approximately +-1 mm. The volume of the cavity was estimated to be approximately 40 mm 3

  12. Hardware Development of Ultrasonic Tomography for Composition Determination of Water and Oil Flow

    Directory of Open Access Journals (Sweden)

    Ruzairi Abdul Rahim

    2007-01-01

    Full Text Available A monitoring system for water and oil flow using ultrasonic Tomography is implemented. Information such as the type of flow, the composition of the water and oil can be obtained from the system. The composition of the flow is determined based on the propagation time of the ultrasonic waves. The ultrasonic Tomography system includes the sensors fixture design, signal conditioning circuits and image reconstruction software. The image reconstruction algorithm that used is the Linear Back Projection (LBP algorithm.

  13. Parametric imaging of collagen structural changes in human osteoarthritic cartilage using optical polarization tractography

    Science.gov (United States)

    Ravanfar, Mohammadreza; Pfeiffer, Ferris M.; Bozynski, Chantelle C.; Wang, Yuanbo; Yao, Gang

    2017-12-01

    Collagen degeneration is an important pathological feature of osteoarthritis. The purpose of this study is to investigate whether the polarization-sensitive optical coherence tomography (PSOCT)-based optical polarization tractography (OPT) can be useful in imaging collagen structural changes in human osteoarthritic cartilage samples. OPT eliminated the banding artifacts in conventional PSOCT by calculating the depth-resolved local birefringence and fiber orientation. A close comparison between OPT and PSOCT showed that OPT provided improved visualization and characterization of the zonal structure in human cartilage. Experimental results obtained in this study also underlined the importance of knowing the collagen fiber orientation in conventional polarized light microscopy assessment. In addition, parametric OPT imaging was achieved by quantifying the surface roughness, birefringence, and fiber dispersion in the superficial zone of the cartilage. These quantitative parametric images provided complementary information on the structural changes in cartilage, which can be useful for a comprehensive evaluation of collagen damage in osteoarthritic cartilage.

  14. Resolution tests of global geodynamic models by travel-time tomography

    Czech Academy of Sciences Publication Activity Database

    Běhounková, Marie; Čížková, H.; Matyska, C.

    2005-01-01

    Roč. 49, č. 3 (2005), s. 343-363 ISSN 0039-3169 R&D Projects: GA ČR GA205/02/1306 Institutional research plan: CEZ:AV0Z30120515 Keywords : seismic tomography * synthetic inversion * resolution tests Subject RIV: DC - Siesmology, Volcanology, Earth Structure Impact factor: 0.656, year: 2005

  15. Development of electrical capacitance sensor for tomography

    International Nuclear Information System (INIS)

    Rasif Mohd Zain; Jaafar Abdullah; Ismail Mustapha; Sazrol Azizee Ariff; Susan Maria Sipaun; Lojius Lombigit

    2004-01-01

    Electrical capacitance tomography (ECT) is one of the successful methods for imaging 2-phase liquid/gas mixture in oil pipelines and solids/gas mixture in fluidized bed and pneumatic conveying system for improvement of process plants. This paper presents the design development of an electrical capacitance sensor for use with an ECT system. This project is aimed at developing a demonstration ECT unit to be used in the oil pipe line. (Author)

  16. The muon tomography Diaphane project : recent upgrades and measurements

    Science.gov (United States)

    Jourde, Kevin; Gibert, Dominique; Marteau, Jacques; de Bremond d'Ars, Jean; Gardien, Serge; Girerd, Claude; Ianigro, Jean-Christophe; Carbone, Daniele

    2014-05-01

    Muon tomography measures the flux of cosmic muons crossing geological bodies to determine their density. Large density heterogeneities were detected on la Soufrière de Guadeloupe revealing its very active phreatic system. These measurements were made possible thanks to electronic and signal processing developments. Indeed the telescopes used to perform these measurements are exposed to noise fluxes with high intensities relative to the tiny flux of interest. A high precision clock permitted to measure upward-going particles coming from the rear of the telescope that used to mix with the volcano signal. Also the particles energy deposit inside the telescope shows that other particles than muons take part to the noise. We present data acquired on la Soufrière, mount Etna in Italy, and in the Mont Terri tunnel in Switzerland. Biases produced on density muon radiographies are quantified and correction procedures are applied.

  17. Effect of ranibizumab on high-speed indocyanine green angiography and minimum intensity projection optical coherence tomography findings in neovascular age-related macular degeneration.

    Science.gov (United States)

    Nicholson, Benjamin P; Nigam, Divya; Toy, Brian; Stetson, Paul F; Agrón, Elvira; Jacobs-El, Naima; Cunningham, Denise; Cukras, Catherine; Wong, Wai; Wiley, Henry; Chew, Emily; Ferris, Frederick; Meyerle, Catherine B

    2015-01-01

    The purpose of this 1-year prospective study was to investigate how induction/pro re nata ranibizumab intravitreal treatment of eyes with neovascular age-related macular degeneration affects the anatomy of choroidal neovascularization (CNV) and the overlying outer retinal tissue. High-speed indocyanine green (HS-ICG) angiography measurements provided quantification of the CNV size in 60 patients followed for 1 year. Minimum intensity projection optical coherence tomography (MinIP OCT), a novel algorithm assessing minimum optical intensity between the internal limiting membrane and retinal pigment epithelium, measured the area of outer retinal disruption overlying the CNV. Fluorescein angiography was also assessed to evaluate late retinal leakage. After 1 year, the mean area of CNV measured with indocyanine green angiography decreased by 5.8%. The mean area of MinIP OCT of outer retinal disruption overlying the CNV decreased by 4.2%. Mean area of fluorescein angiography leakage decreased by 6.3%. Both the area of outer retinal disruption measured with MinIP OCT and the area of leakage on fluorescein angiography typically exceeded the area of CNV on indocyanine green angiography at baseline and 1 year. Choroidal neovascularization treated with induction/pro re nata intravitreal ranibizumab for 1 year essentially remained static. Minimum intensity projection optical coherence tomography suggests that the area of outer retinal disruption overlying the CNV may be greater than the CNV itself and often correlates with the leakage area on fluorescein angiography. Additionally, there was minimal change in the area of outer retinal disruption on MinIP OCT even when fluid resolved. Measurements of the extent of CNV lesions based on indocyanine green angiography and MinIP OCT may provide useful outcome variables to help assess the CNV complex longitudinally and warrant further validation.

  18. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... Physician Resources Professions Site Index A-Z Computed Tomography (CT) - Sinuses Computed tomography (CT) of the sinuses ... CT of the Sinuses? What is CT (Computed Tomography) of the Sinuses? Computed tomography, more commonly known ...

  19. Limited-angle tomography for analyzer-based phase-contrast x-ray imaging

    International Nuclear Information System (INIS)

    Majidi, Keivan; Wernick, Miles N; Brankov, Jovan G; Li, Jun; Muehleman, Carol

    2014-01-01

    Multiple-image radiography (MIR) is an analyzer-based phase-contrast x-ray imaging method, which is emerging as a potential alternative to conventional radiography. MIR simultaneously generates three planar parametric images containing information about scattering, refraction and attenuation properties of the object. The MIR planar images are linear tomographic projections of the corresponding object properties, which allows reconstruction of volumetric images using computed tomography (CT) methods. However, when acquiring a full range of linear projections around the tissue of interest is not feasible or the scanning time is limited, limited-angle tomography techniques can be used to reconstruct these volumetric images near the central plane, which is the plane that contains the pivot point of the tomographic movement. In this work, we use computer simulations to explore the applicability of limited-angle tomography to MIR. We also investigate the accuracy of reconstructions as a function of number of tomographic angles for a fixed total radiation exposure. We use this function to find an optimal range of angles over which data should be acquired for limited-angle tomography MIR (LAT-MIR). Next, we apply the LAT-MIR technique to experimentally acquired MIR projections obtained in a cadaveric human thumb study. We compare the reconstructed slices near the central plane to the same slices reconstructed by CT-MIR using the full angular view around the object. Finally, we perform a task-based evaluation of LAT-MIR performance for different numbers of angular views, and use template matching to detect cartilage in the refraction image near the central plane. We use the signal-to-noise ratio of this test as the detectability metric to investigate an optimum range of tomographic angles for detecting soft tissues in LAT-MIR. Both results show that there is an optimum range of angular view for data acquisition where LAT-MIR yields the best performance, comparable to CT

  20. Limited-angle tomography for analyzer-based phase-contrast x-ray imaging

    Science.gov (United States)

    Majidi, Keivan; Wernick, Miles N.; Li, Jun; Muehleman, Carol; Brankov, Jovan G.

    2014-07-01

    Multiple-image radiography (MIR) is an analyzer-based phase-contrast x-ray imaging method, which is emerging as a potential alternative to conventional radiography. MIR simultaneously generates three planar parametric images containing information about scattering, refraction and attenuation properties of the object. The MIR planar images are linear tomographic projections of the corresponding object properties, which allows reconstruction of volumetric images using computed tomography (CT) methods. However, when acquiring a full range of linear projections around the tissue of interest is not feasible or the scanning time is limited, limited-angle tomography techniques can be used to reconstruct these volumetric images near the central plane, which is the plane that contains the pivot point of the tomographic movement. In this work, we use computer simulations to explore the applicability of limited-angle tomography to MIR. We also investigate the accuracy of reconstructions as a function of number of tomographic angles for a fixed total radiation exposure. We use this function to find an optimal range of angles over which data should be acquired for limited-angle tomography MIR (LAT-MIR). Next, we apply the LAT-MIR technique to experimentally acquired MIR projections obtained in a cadaveric human thumb study. We compare the reconstructed slices near the central plane to the same slices reconstructed by CT-MIR using the full angular view around the object. Finally, we perform a task-based evaluation of LAT-MIR performance for different numbers of angular views, and use template matching to detect cartilage in the refraction image near the central plane. We use the signal-to-noise ratio of this test as the detectability metric to investigate an optimum range of tomographic angles for detecting soft tissues in LAT-MIR. Both results show that there is an optimum range of angular view for data acquisition where LAT-MIR yields the best performance, comparable to CT

  1. Tomography of images with poisson miose: pre-processing of projections

    International Nuclear Information System (INIS)

    Furuie, S.S.

    1989-01-01

    This work present an alternative approach in order to reconstruct images with low signal to noise ratio. Basically it consist of smoothing projections taking into account that the noise is Poisson. These filtered projections are used to reconstruct the original image, applying direct Fourier method. This approach is compared with convolution back projection and EM (Expectation-Maximization). (author) [pt

  2. Automated discrete electron tomography – Towards routine high-fidelity reconstruction of nanomaterials

    International Nuclear Information System (INIS)

    Zhuge, Xiaodong; Jinnai, Hiroshi; Dunin-Borkowski, Rafal E.; Migunov, Vadim; Bals, Sara; Cool, Pegie; Bons, Anton-Jan; Batenburg, Kees Joost

    2017-01-01

    Electron tomography is an essential imaging technique for the investigation of morphology and 3D structure of nanomaterials. This method, however, suffers from well-known missing wedge artifacts due to a restricted tilt range, which limits the objectiveness, repeatability and efficiency of quantitative structural analysis. Discrete tomography represents one of the promising reconstruction techniques for materials science, potentially capable of delivering higher fidelity reconstructions by exploiting the prior knowledge of the limited number of material compositions in a specimen. However, the application of discrete tomography to practical datasets remains a difficult task due to the underlying challenging mathematical problem. In practice, it is often hard to obtain consistent reconstructions from experimental datasets. In addition, numerous parameters need to be tuned manually, which can lead to bias and non-repeatability. In this paper, we present the application of a new iterative reconstruction technique, named TVR-DART, for discrete electron tomography. The technique is capable of consistently delivering reconstructions with significantly reduced missing wedge artifacts for a variety of challenging data and imaging conditions, and can automatically estimate its key parameters. We describe the principles of the technique and apply it to datasets from three different types of samples acquired under diverse imaging modes. By further reducing the available tilt range and number of projections, we show that the proposed technique can still produce consistent reconstructions with minimized missing wedge artifacts. This new development promises to provide the electron microscopy community with an easy-to-use and robust tool for high-fidelity 3D characterization of nanomaterials. - Highlights: • Automated discrete electron tomography capable of consistently delivering reconstructions with significantly reduced missing wedge artifacts and requires significantly

  3. Automated discrete electron tomography – Towards routine high-fidelity reconstruction of nanomaterials

    Energy Technology Data Exchange (ETDEWEB)

    Zhuge, Xiaodong [Computational Imaging, Centrum Wiskunde & Informatica, Science park 123, 1098XG Amsterdam (Netherlands); Jinnai, Hiroshi [Institute of Multidisciplinary Research for Advanced Materials, Tohoku University, Katahira 2-1-1, Aoba-ku, Sendai 980-8577 (Japan); Dunin-Borkowski, Rafal E.; Migunov, Vadim [Ernst Ruska-Centre for Microscopy and Spectroscopy with Electrons and Peter Grünberg Institute, Forschungszentrum Jülich, D-52425 Jülich (Germany); Bals, Sara [EMAT, University of Antwerp, Groenenborgerlaan 171, B-2020 Antwerp (Belgium); Cool, Pegie [Laboratory of Adsorption and Catalysis, Department of Chemistry, University of Antwerp, Universiteitsplein 1, 2610 Wilrijk (Belgium); Bons, Anton-Jan [European Technology Center, ExxonMobil Chemical Europe Inc., Hermeslaan 2, B-1831 Machelen (Belgium); Batenburg, Kees Joost [Computational Imaging, Centrum Wiskunde & Informatica, Science park 123, 1098XG Amsterdam (Netherlands)

    2017-04-15

    Electron tomography is an essential imaging technique for the investigation of morphology and 3D structure of nanomaterials. This method, however, suffers from well-known missing wedge artifacts due to a restricted tilt range, which limits the objectiveness, repeatability and efficiency of quantitative structural analysis. Discrete tomography represents one of the promising reconstruction techniques for materials science, potentially capable of delivering higher fidelity reconstructions by exploiting the prior knowledge of the limited number of material compositions in a specimen. However, the application of discrete tomography to practical datasets remains a difficult task due to the underlying challenging mathematical problem. In practice, it is often hard to obtain consistent reconstructions from experimental datasets. In addition, numerous parameters need to be tuned manually, which can lead to bias and non-repeatability. In this paper, we present the application of a new iterative reconstruction technique, named TVR-DART, for discrete electron tomography. The technique is capable of consistently delivering reconstructions with significantly reduced missing wedge artifacts for a variety of challenging data and imaging conditions, and can automatically estimate its key parameters. We describe the principles of the technique and apply it to datasets from three different types of samples acquired under diverse imaging modes. By further reducing the available tilt range and number of projections, we show that the proposed technique can still produce consistent reconstructions with minimized missing wedge artifacts. This new development promises to provide the electron microscopy community with an easy-to-use and robust tool for high-fidelity 3D characterization of nanomaterials. - Highlights: • Automated discrete electron tomography capable of consistently delivering reconstructions with significantly reduced missing wedge artifacts and requires significantly

  4. 16 CFR 316.5 - Prohibition on charging a fee or imposing other requirements on recipients who wish to opt out.

    Science.gov (United States)

    2010-01-01

    ... other than the recipient's electronic mail address and opt-out preferences, or take any other steps except sending a reply electronic mail message or visiting a single Internet Web page, in order to: (a) Use a return electronic mail address or other Internet-based mechanism, required by 15 U.S.C. 7704(a...

  5. Well-being and associated factors among adults in the occupied Palestinian territory (oPt).

    Science.gov (United States)

    Harsha, Nouh; Ziq, Luay; Ghandour, Rula; Giacaman, Rita

    2016-08-30

    The World Health Organization (WHO) incorporated well-being into its definition of health in 1948. The significance given to this concept is due to its role in the assessment of people's quality of life and health. Using the WHO Well-being Index, we estimated well-being among adults and identified selected associated factors in the occupied Palestinian territory (oPt) using data obtained from the National Time Use Survey conducted by the Palestinian Central Bureau of Statistics (PCBS) 2012-2013 on a representative sample of persons living in the West Bank and Gaza Strip. Univariate and bivariate analyses were conducted among participants 18 years old and above. Multivariate analysis (Regression) was performed with factors found significant in cross-tabulations, using SPSS® version 20. Overall, 33.8 % (2395) of respondents reported low levels of well-being (ill-being). Neither age, nor sex, nor region were found significant in regression analysis. People who were married, working 15 h or more, with a higher standard of living, who reported participating in community, cultural, and social events, or in religious activities reported high levels of well-being. Those who reported regularly following the mass media, or living in Palestinian refugee camps reported low levels of wellbeing. Overall, about one-third of adult Palestinians reported low levels of well-being (ill-being), a finding which in itself requires attention. Marriage, employment, high living standards, community participation, and religious activities were found to be protective against ill-being. Further investigations are required to determine additional causes of ill-being in the oPt, taking into consideration the possible effects of chronic exposure to political violence on subjective well-being.

  6. Three-dimensional imaging of Drosophila melanogaster.

    Directory of Open Access Journals (Sweden)

    Leeanne McGurk

    2007-09-01

    Full Text Available The major hindrance to imaging the intact adult Drosophila is that the dark exoskeleton makes it impossible to image through the cuticle. We have overcome this obstacle and describe a method whereby the internal organs of adult Drosophila can be imaged in 3D by bleaching and clearing the adult and then imaging using a technique called optical projection tomography (OPT. The data is displayed as 2D optical sections and also in 3D to provide detail on the shape and structure of the adult anatomy.We have used OPT to visualize in 2D and 3D the detailed internal anatomy of the intact adult Drosophila. In addition this clearing method used for OPT was tested for imaging with confocal microscopy. Using OPT we have visualized the size and shape of neurodegenerative vacuoles from within the head capsule of flies that suffer from age-related neurodegeneration due to a lack of ADAR mediated RNA-editing. In addition we have visualized tau-lacZ expression in 2D and 3D. This shows that the wholemount adult can be stained without any manipulation and that this stain penetrates well as we have mapped the localization pattern with respect to the internal anatomy.We show for the first time that the intact adult Drosophila can be imaged in 3D using OPT, also we show that this method of clearing is also suitable for confocal microscopy to image the brain from within the intact head. The major advantage of this is that organs can be represented in 3D in their natural surroundings. Furthermore optical sections are generated in each of the three planes and are not prone to the technical limitations that are associated with manual sectioning. OPT can be used to dissect mutant phenotypes and to globally map gene expression in both 2D and 3D.

  7. Scanning transmission ion micro-tomography (STIM-T) of biological specimens

    International Nuclear Information System (INIS)

    Schwertner, Michael; Sakellariou, Arthur; Reinert, Tilo; Butz, Tilman

    2006-01-01

    Computed tomography (CT) was applied to sets of Scanning Transmission Ion Microscopy (STIM) projections recorded at the LIPSION ion beam laboratory (Leipzig) in order to visualize the 3D-mass distribution in several specimens. Examples for a test structure (copper grid) and for biological specimens (cartilage cells, cygospore) are shown. Scanning Transmission Micro-Tomography (STIM-T) at a resolution of 260 nm was demonstrated for the first time. Sub-micron features of the Cu-grid specimen were verified by scanning electron microscopy. The ion energy loss measured during a STIM-T experiment is related to the mass density of the specimen. Typically, biological specimens can be analysed without staining. Only shock freezing and freeze-drying is required to preserve the ultra-structure of the specimen. The radiation damage to the specimen during the experiment can be neglected. This is an advantage compared to other techniques like X-ray micro-tomography. At present, the spatial resolution is limited by beam position fluctuations and specimen vibrations

  8. In Vivo Diffuse Optical Tomography and Fluorescence Molecular Tomography

    Directory of Open Access Journals (Sweden)

    Mingze Li

    2010-01-01

    Full Text Available Diffuse optical tomography (DOT and fluorescence molecular tomography (FMT are two attractive imaging techniques for in vivo physiological and psychological research. They have distinct advantages such as non-invasiveness, non-ionizing radiation, high sensitivity and longitudinal monitoring. This paper reviews the key components of DOT and FMT. Light propagation model, mathematical reconstruction algorithm, imaging instrumentation and medical applications are included. Future challenges and perspective on optical tomography are discussed.

  9. Inter laboratory comparison on Computed Tomography for industrial applications in the slaughterhouses

    DEFF Research Database (Denmark)

    Angel, Jais Andreas Breusch; Christensen, Lars Bager; Cantatore, Angela

    2014-01-01

    An intercomparison on X-ray Computed Tomography (CT) for industrial applications in the slaughterhouses was organized by the Centre for Geometrical Metrology (CGM), Department of Mechanical Engineering, Technical University of Denmark (DTU) and carried out within the project “Centre for Industrial...

  10. Analytically derived weighting factors for transmission tomography cone beam projections

    International Nuclear Information System (INIS)

    Yao Weiguang; Leszczynski, Konrad

    2009-01-01

    Weighting factors, which define the contributions of individual voxels of a 3D object to individual projection elements (pixels) on the detector, are the basic elements required in iterative tomographic reconstructions from transmission projections. Exact or as accurate as possible values for weighting factors are required in high-resolution reconstructions. Geometric complexity of the problem, however, makes it difficult to obtain exact weighting factor values. In this work, we derive an analytical expression for the weighting factors in cone beam projection geometry. The resulting formula is validated and applied to reconstruction from mega and kilovoltage x-ray cone beam projections. The reconstruction speed and accuracy are significantly improved by using the weighting factor values.

  11. Behavior of the maximum likelihood in quantum state tomography

    Science.gov (United States)

    Scholten, Travis L.; Blume-Kohout, Robin

    2018-02-01

    Quantum state tomography on a d-dimensional system demands resources that grow rapidly with d. They may be reduced by using model selection to tailor the number of parameters in the model (i.e., the size of the density matrix). Most model selection methods typically rely on a test statistic and a null theory that describes its behavior when two models are equally good. Here, we consider the loglikelihood ratio. Because of the positivity constraint ρ ≥ 0, quantum state space does not generally satisfy local asymptotic normality (LAN), meaning the classical null theory for the loglikelihood ratio (the Wilks theorem) should not be used. Thus, understanding and quantifying how positivity affects the null behavior of this test statistic is necessary for its use in model selection for state tomography. We define a new generalization of LAN, metric-projected LAN, show that quantum state space satisfies it, and derive a replacement for the Wilks theorem. In addition to enabling reliable model selection, our results shed more light on the qualitative effects of the positivity constraint on state tomography.

  12. Behavior of the maximum likelihood in quantum state tomography

    Energy Technology Data Exchange (ETDEWEB)

    Blume-Kohout, Robin J [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Univ. of New Mexico, Albuquerque, NM (United States); Scholten, Travis L. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Univ. of New Mexico, Albuquerque, NM (United States)

    2018-02-22

    Quantum state tomography on a d-dimensional system demands resources that grow rapidly with d. They may be reduced by using model selection to tailor the number of parameters in the model (i.e., the size of the density matrix). Most model selection methods typically rely on a test statistic and a null theory that describes its behavior when two models are equally good. Here, we consider the loglikelihood ratio. Because of the positivity constraint ρ ≥ 0, quantum state space does not generally satisfy local asymptotic normality (LAN), meaning the classical null theory for the loglikelihood ratio (the Wilks theorem) should not be used. Thus, understanding and quantifying how positivity affects the null behavior of this test statistic is necessary for its use in model selection for state tomography. We define a new generalization of LAN, metric-projected LAN, show that quantum state space satisfies it, and derive a replacement for the Wilks theorem. In addition to enabling reliable model selection, our results shed more light on the qualitative effects of the positivity constraint on state tomography.

  13. OptEase and TrapEase Vena Cava Filters: A Single-Center Experience in 258 Patients

    International Nuclear Information System (INIS)

    Onat, Levent; Ganiyusufoglu, Ali Kursat; Mutlu, Ayhan; Sirvanci, Mustafa; Duran, Cihan; Ulusoy, Onur Levent; Hamzaoglu, Azmi

    2009-01-01

    We aimed to evaluate the efficacy and safety of the OptEase and TrapEase (both from Cordis, Roden, Netherlands) vena cava filters in the prevention of pulmonary embolism (PE). Between May 2004 and December 2008, OptEase (permanent/retrievable; n = 228) or TrapEase (permanent; n = 30) vena cava filters were placed in 258 patients (160 female and 98 male; mean age 62 years [range 22 to 97]). Indications were as follows: prophylaxis for PE (n = 239), contraindication for anticoagulation in the presence of PE or DVT (n = 10), and development of PE or DVT despite anticoagulation (n = 9). Medical records were retrospectively reviewed for indications, clinical results, and procedure-related complications during placement and retrieval. Clinical PE did not develop in any of the patients. However, radiologic signs of segmental PE were seen in 6 of 66 patients with follow-up imaging data. Migration or fracture of the filter or cava perforation was not seen in any of the patients. Except for a single case of asymptomatic total cava thrombosis, no thrombotic occlusion was observed. One hundred forty-one patients were scheduled to undergo filter removal; however, 17 of them were not suitable for such based on venography evaluation. Removal was attempted in 124 patients and was successful in 115 of these (mean duration of retention 11 days [range 4 to 23]). Nine filters could not be removed. Permanent/retrievable vena cava filters are safe and effective devices for PE prophylaxis and for the management of venous thromboembolism by providing the option to be left in place.

  14. THz computed tomography system with zero-order Bessel beam

    Science.gov (United States)

    Niu, Liting; Wu, Qiao; Wang, Kejia; Liu, Jinsong; Yang, Zhengang

    2018-01-01

    Terahertz (THz) waves can penetrate many optically opaque dielectric materials such as plastics, ceramics and colorants. It is effective to reveal the internal structures of these materials. We have built a THz Computed Tomography (CT) system with 0.3 THz zero-order Bessel beam to improve the depth of focus of this imaging system for the non-diffraction property of Bessel beam. The THz CT system has been used to detect a paper cup with a metal rod inside. Finally, the acquired projection data have been processed by the filtered back-projection algorithm and the reconstructed image of the sample has been obtained.

  15. Homotopic non-local regularized reconstruction from sparse positron emission tomography measurements

    International Nuclear Information System (INIS)

    Wong, Alexander; Liu, Chenyi; Wang, Xiao Yu; Fieguth, Paul; Bie, Hongxia

    2015-01-01

    Positron emission tomography scanners collect measurements of a patient’s in vivo radiotracer distribution. The system detects pairs of gamma rays emitted indirectly by a positron-emitting radionuclide (tracer), which is introduced into the body on a biologically active molecule, and the tomograms must be reconstructed from projections. The reconstruction of tomograms from the acquired PET data is an inverse problem that requires regularization. The use of tightly packed discrete detector rings, although improves signal-to-noise ratio, are often associated with high costs of positron emission tomography systems. Thus a sparse reconstruction, which would be capable of overcoming the noise effect while allowing for a reduced number of detectors, would have a great deal to offer. In this study, we introduce and investigate the potential of a homotopic non-local regularization reconstruction framework for effectively reconstructing positron emission tomograms from such sparse measurements. Results obtained using the proposed approach are compared with traditional filtered back-projection as well as expectation maximization reconstruction with total variation regularization. A new reconstruction method was developed for the purpose of improving the quality of positron emission tomography reconstruction from sparse measurements. We illustrate that promising reconstruction performance can be achieved for the proposed approach even at low sampling fractions, which allows for the use of significantly fewer detectors and have the potential to reduce scanner costs

  16. Optimized production technology (OPT), theory of constraints (TOC) og den dertil hørende økonomistyringstankegang 'Throughput Accounting (TPA)'

    DEFF Research Database (Denmark)

    Nielsen, Steen; Hansen, Tom Albæk

    2005-01-01

    Kombinationen af økonomistyring med forskellige andre funktionsområder, f.eks., indkøb, produktion, afsætning, adfærd etc., er et vigtigt område, og udgør efterhånden en del af det pensum, som repræsenteres i diverse lærebøger indenfor cost management accounting. OPT, TOC, TPA, samt også modeller...... som Just-In-Time (JIT) og Life-Cycle-Costing (LCC) vil fremover kunne give inspiration til nye måder at anskue økonomistyringen på. TOC, JIT og LCC kombineres ofte, både i relation til de mere operative beslutninger, men også i relation til virksomhedens strategiledelse. Ideen er, at også de...... separat eller i kombination. På denne måde bør de kunne støtte virksomhedens strategi og dermed den samlede lønsomhed. Hvor OPT sætter fokus på at optimere produktionen, sætter TOC og TPA fokus på udnyttelse af produktionsapparatet og på likviditeten. TPA minder på mange måder om bidragsmodellen og den...

  17. Compressed sensing electron tomography

    International Nuclear Information System (INIS)

    Leary, Rowan; Saghi, Zineb; Midgley, Paul A.; Holland, Daniel J.

    2013-01-01

    The recent mathematical concept of compressed sensing (CS) asserts that a small number of well-chosen measurements can suffice to reconstruct signals that are amenable to sparse or compressible representation. In addition to powerful theoretical results, the principles of CS are being exploited increasingly across a range of experiments to yield substantial performance gains relative to conventional approaches. In this work we describe the application of CS to electron tomography (ET) reconstruction and demonstrate the efficacy of CS–ET with several example studies. Artefacts present in conventional ET reconstructions such as streaking, blurring of object boundaries and elongation are markedly reduced, and robust reconstruction is shown to be possible from far fewer projections than are normally used. The CS–ET approach enables more reliable quantitative analysis of the reconstructions as well as novel 3D studies from extremely limited data. - Highlights: • Compressed sensing (CS) theory and its application to electron tomography (ET) is described. • The practical implementation of CS–ET is outlined and its efficacy demonstrated with examples. • High fidelity tomographic reconstruction is possible from a small number of images. • The CS–ET reconstructions can be more reliably segmented and analysed quantitatively. • CS–ET is applicable to different image content by choice of an appropriate sparsifying transform

  18. Positron emission tomography

    International Nuclear Information System (INIS)

    Reivich, M.; Alavi, A.

    1985-01-01

    This book contains 24 selections. Some of the titles are: Positron Emission Tomography Instrumentation, Generator Systems for Positron Emitters, Reconstruction Algorithms, Cerebral Glucose Consumption: Methodology and Validation, Cerebral Blood Flow Tomography Using Xenon-133 Inhalation: Methods and Clinical Applications, PET Studies of Stroke, Cardiac Positron Emission Tomography, and Use of PET in Oncology

  19. Qualitative and quantitative assessment of the short- and long-term consequences of opting out of nuclear energy

    International Nuclear Information System (INIS)

    Briem, G.; Halstrick, M.; Heilemann, U.; Hillebrand, B.; Kiy, M.; Neuhaus, R.; Knieper, O.; Schmidt, H.W.; Weiss, T.

    1986-08-01

    A reference scenario establishes the prospective development of the energy and overall economy under status-quo conditions, i.e. assuming especially the continued use of nuclear energy, while two scenarios (alternative I: 'immediate opting out' and alternative II: 'opting out in the long term') try to assess the consequences of a shutdown of nuclear energy for the economic development of the Federal Republic of Germany. Especially, the study deals with the effects on the power industry, the ecological consequences, and the overall economic effects both in the short and long run. In all three scenarios, the development of the home consumption of electric power is first of all determined by a structure model of the entire economy. The capacity required to meet that demand and its use are calculated with the aid of a power plant model; short- and long-term cost-minimization programmes making allowance especially for fuel and capital costs from the elements from which these quantities are derived. Fuel and capital costs operate as variables in the structure model to determine the sectoral and overall economic development. The report in addition investigates separately, in partial models, the effects on the chemical industry and the branches of industry processing iron, steel, and non-ferrous metals, all of which are greatly in demand of electric power. (orig./UA) [de

  20. Comparison between conventional tomography and computer tomography in diseases of the sacroiliac joints

    International Nuclear Information System (INIS)

    Moritz, J.D.; Ganter, H.; Winter, C.; Evangelisches Krankenhaus, Giessen

    1990-01-01

    16 patients with diseases of the sacroiliac joints were examined both with computer tomography and with conventional tomography. Both techniques were characterized by a high sensitivity. Computer tomography was superior in exactly delineating the extent of the pathologic changes. In conventional tomography the joint surface was more blurred, erosions were larger, and signs of ankylosis were more expanded, so that the joints seemed to be more altered in 8 cases than demonstrated by computer tomography. Very accurate changes like subchondral cysts were recognized only in the computer tomograms. In all cases in which anteroposterior radiographs revealed no clear result, the authors recommend to additionally employ computer tomography. (orig.) [de

  1. Three-dimensional structural analysis of eukaryotic flagella/cilia by electron cryo-tomography

    International Nuclear Information System (INIS)

    Bui, Khanh Huy; Pigino, Gaia; Ishikawa, Takashi

    2011-01-01

    Based on the molecular architecture revealed by electron cryo-tomography, the mechanism of the bending motion of eukaryotic flagella/cilia is discussed. Electron cryo-tomography is a potential approach to analyzing the three-dimensional conformation of frozen hydrated biological macromolecules using electron microscopy. Since projections of each individual object illuminated from different orientations are merged, electron tomography is capable of structural analysis of such heterogeneous environments as in vivo or with polymorphism, although radiation damage and the missing wedge are severe problems. Here, recent results on the structure of eukaryotic flagella, which is an ATP-driven bending organelle, from green algae Chlamydomonas are presented. Tomographic analysis reveals asymmetric molecular arrangements, especially that of the dynein motor proteins, in flagella, giving insight into the mechanism of planar asymmetric bending motion. Methodological challenges to obtaining higher-resolution structures from this technique are also discussed

  2. Extremely tortuous coronary arteries - when optical coherence tomography and fractional flow reserve did not help us much

    Directory of Open Access Journals (Sweden)

    Miloradović Vladimir

    2018-01-01

    Full Text Available Introduction. Extreme coronary tortuosity may lead to flow alteration resulting in a reduction in coronary pressure distal to the tortuous segment, subsequently leading to ischemia. Therefore the detection of a true cause of ischemia, i.e. whether a fixed stenosis or tortuosity by itself is responsible for its creation, with non-invasive and invasive methods is a real challenge. Case report. We presented a case of a patient with a history of stable angina [Canadian Cardiovascular Society (CCS class II], an abnormal stress test and coronary tortuosity without hemodynamically significant stenosis. Due to suspected linear lesion between the two bends in proximal segment of Right coronary artery (RCA we performed optical coherence tomography (OCT, minimum lumen area (MLA-13.19 mm2 and fractional flow reserve (FFR RCA (0.94. We opted for conservative treatment for stable angina. Conclusion. When tortuosities are associated with atherosclerosis in coronary artery for determination of true cause of ischemia invasive methods can be used, such as OCT and FFR.

  3. The role of (18)fluoro-deoxyglucose positron emission tomography/computed tomography in resectable pancreatic cancer.

    Science.gov (United States)

    Crippa, Stefano; Salgarello, Matteo; Laiti, Silvia; Partelli, Stefano; Castelli, Paola; Spinelli, Antonello E; Tamburrino, Domenico; Zamboni, Giuseppe; Falconi, Massimo

    2014-08-01

    The role of (18)fluoro-deoxyglucose positron emission tomography/computed tomography in pancreatic ductal adenocarcinoma is debated. We retrospectively assessed the value of (18)fluoro-deoxyglucose positron emission tomography/computed tomography in addition to conventional imaging as a staging modality in pancreatic cancer. (18)Fluoro-deoxyglucose positron emission tomography/computed tomography was performed in 72 patients with resectable pancreatic carcinoma after multi-detector computed tomography positron emission tomography was considered positive for a maximum standardized uptake value >3. Overall, 21% of patients had a maximum standardized uptake value ≤ 3, and 60% of those had undergone neoadjuvant treatment (P=0.0001). Furthermore, 11% of patients were spared unwarranted surgery since positron emission tomography/computed tomography detected metastatic disease. All liver metastases were subsequently identified with contrast-enhanced ultrasound. Sensitivity and specificity of positron emission tomography/computed tomography for distant metastases were 78% and 100%. The median CA19.9 concentration was 48.8 U/mL for the entire cohort and 292 U/mL for metastatic patients (P=0.112). The widespread application of (18)fluoro-deoxyglucose positron emission tomography/computed tomography in patients with resectable pancreatic carcinoma seems not justified. It should be considered in selected patients at higher risk of metastatic disease (i.e. CA19.9>200 U/mL) after undergoing other imaging tests. Neoadjuvant treatment is significantly associated with low metabolic activity, limiting the value of positron emission tomography in this setting. Copyright © 2014 Editrice Gastroenterologica Italiana S.r.l. Published by Elsevier Ltd. All rights reserved.

  4. Factors influencing patients with stage 5 chronic kidney disease to opt for conservative management: a practitioner research study

    OpenAIRE

    Johnston, Sheila; Noble, Helen

    2012-01-01

    Aims and objectives. This study explored decision-making experiences of patients with stage 5 chronic kidney disease when opting for conservative management of their renal failure.Background. Dialysis is an invasive treatment, and for some older patients, there is an associated treatment burden of dialysis-related symptoms. An alternative choice is conservative management, but little is known about those who make this decision and how they are supported through the process.Design. Qualitative...

  5. CTmod—A toolkit for Monte Carlo simulation of projections including scatter in computed tomography

    Czech Academy of Sciences Publication Activity Database

    Malušek, Alexandr; Sandborg, M.; Alm Carlsson, G.

    2008-01-01

    Roč. 90, č. 2 (2008), s. 167-178 ISSN 0169-2607 Institutional research plan: CEZ:AV0Z10480505 Keywords : Monte Carlo * computed tomography * cone beam * scatter Subject RIV: JC - Computer Hardware ; Software Impact factor: 1.220, year: 2008 http://dx.doi.org/10.1016/j.cmpb.2007.12.005

  6. Attenuation Correction Strategies for Positron Emission Tomography/Computed Tomography and 4-Dimensional Positron Emission Tomography/Computed Tomography

    OpenAIRE

    Pan, Tinsu; Zaidi, Habib

    2013-01-01

    This article discusses attenuation correction strategies in positron emission tomography/computed tomography (PET/CT) and 4 dimensional PET/CT imaging. Average CT scan derived from averaging the high temporal resolution CT images is effective in improving the registration of the CT and the PET images and quantification of the PET data. It underscores list mode data acquisition in 4 dimensional PET and introduces 4 dimensional CT popular in thoracic treatment planning to 4 dimensional PET/CT. ...

  7. Simulated annealing image reconstruction for positron emission tomography

    International Nuclear Information System (INIS)

    Sundermann, E.; Lemahieu, I.; Desmedt, P.

    1994-01-01

    In Positron Emission Tomography (PET) images have to be reconstructed from moisy projection data. The noise on the PET data can be modeled by a Poison distribution. In this paper, we present the results of using the simulated annealing technique to reconstruct PET images. Various parameter settings of the simulated annealing algorithm are discussed and optimized. The reconstructed images are of good quality and high contrast, in comparison to other reconstruction techniques. (authors)

  8. A path finding implementation for multi-layer networks

    NARCIS (Netherlands)

    Dijkstra, F.; van der Ham, J.; Grosso, P.; de Laat, C.

    2009-01-01

    The goal of the OptIPuter project is to tightly couple research applications with dynamically allocated paths. Since OptIPuter is a multi-disciplinary project, the paths through the network often span multiple network domains, and the applications are challenged to find valid network connections

  9. A path finding implementation for multi-layer network

    NARCIS (Netherlands)

    Dijkstra, F.; Ham, J.J. van der; Grosso, P.; Laat, C. de

    2009-01-01

    The goal of the OptIPuter project is to tightly couple research applications with dynamically allocated paths. Since OptIPuter is a multi-disciplinary project, the paths through the network often span multiple network domains, and the applications are challenged to find valid network connections

  10. Imaging performance of a hybrid x-ray computed tomography-fluorescence molecular tomography system using priors.

    Science.gov (United States)

    Ale, Angelique; Schulz, Ralf B; Sarantopoulos, Athanasios; Ntziachristos, Vasilis

    2010-05-01

    The performance is studied of two newly introduced and previously suggested methods that incorporate priors into inversion schemes associated with data from a recently developed hybrid x-ray computed tomography and fluorescence molecular tomography system, the latter based on CCD camera photon detection. The unique data set studied attains accurately registered data of high spatially sampled photon fields propagating through tissue along 360 degrees projections. Approaches that incorporate structural prior information were included in the inverse problem by adding a penalty term to the minimization function utilized for image reconstructions. Results were compared as to their performance with simulated and experimental data from a lung inflammation animal model and against the inversions achieved when not using priors. The importance of using priors over stand-alone inversions is also showcased with high spatial sampling simulated and experimental data. The approach of optimal performance in resolving fluorescent biodistribution in small animals is also discussed. Inclusion of prior information from x-ray CT data in the reconstruction of the fluorescence biodistribution leads to improved agreement between the reconstruction and validation images for both simulated and experimental data.

  11. Doses optimization to patients in computed tomography studies

    International Nuclear Information System (INIS)

    Trujillo Z, F. E.

    2010-09-01

    in recent years the number of studies of computed tomography has been increased, as well as the technology and methodology of these, while the radiological protection to the patient has not advanced to the same step. The IAEA has implemented the Patients Radiation Protection projects, where one of the areas of more interest is the computed tomography. The present work is a brief summary of the actions to realize for the doses optimization imparted to the patients, obtaining an appropriate diagnostic quality in the images at the same time; as it was presented in the course of the project C-RLA/9/067-001. The results that were obtained between Image Quality and Dose by Radiation that is imparted to the patient are shown, as well s the exposition factors that influence in these, according to the project C-RLA/9/067-001. The main actions for the dose optimization are using tension optimized protocols (kV), of load (m As), of collimation/cut thickness, of inclination of the gantry, of the pitch/displacement by rotation, of the reconstruction algorithm (kernel), according to the diagnostic objective to reach and to the patient physical characteristics (like weight and age), as well as to use protections to shield the sensitive organs (mainly those that do not have clinical interest for the procedure). Conclusion: To establish or to begin to implement, insofar as possible, the IAEA recommendations, relating to the clinical practice of the hospitals in Mexico and to the available equipment s type. (Author)

  12. Emission computed tomography

    International Nuclear Information System (INIS)

    Ott, R.J.

    1986-01-01

    Emission Computed Tomography is a technique used for producing single or multiple cross-sectional images of the distribution of radionuclide labelled agents in vivo. The techniques of Single Photon Emission Computed Tomography (SPECT) and Positron Emission Tomography (PET) are described with particular regard to the function of the detectors used to produce images and the computer techniques used to build up images. (UK)

  13. Discrete tomography in neutron radiography

    International Nuclear Information System (INIS)

    Kuba, Attila; Rodek, Lajos; Kiss, Zoltan; Rusko, Laszlo; Nagy, Antal; Balasko, Marton

    2005-01-01

    Discrete tomography (DT) is an imaging technique for reconstructing discrete images from their projections using the knowledge that the object to be reconstructed contains only a few homogeneous materials characterized by known discrete absorption values. One of the main reasons for applying DT is that we will hopefully require relatively few projections. Using discreteness and some a priori information (such as an approximate shape of the object) we can apply two DT methods in neutron imaging by reducing the problem to an optimization task. The first method is a special one because it is only suitable if the object is composed of cylinders and sphere shapes. The second method is a general one in the sense that it can be used for reconstructing objects of any shape. Software was developed and physical experiments performed in order to investigate the effects of several reconstruction parameters: the number of projections, noise levels, and complexity of the object to be reconstructed. We give a summary of the experimental results and make a comparison of the results obtained using a classical reconstruction technique (FBP). The programs we developed are available in our DT reconstruction program package DIRECT

  14. Review of muon tomography

    International Nuclear Information System (INIS)

    Feng Hanliang; Jiao Xiaojing

    2010-01-01

    As a new detection technology, Muon tomography has some potential benefits, such as being able to form a three- dimensional image, without radiation, low cost, fast detecting etc. Especially, muon tomography will play an important role in detecting nuclear materials. It introduces the theory of Muon tomography, its advantages and the Muon tomography system developed by decision sciences corporation and Los Alamos national laboratory. (authors)

  15. Borehole radar diffraction tomography

    Energy Technology Data Exchange (ETDEWEB)

    Cho, Seong Jun; Kim, Jung Ho; Yi, Myeong Jong; Chung, Seung Hwan; Lee, Hee Il [Korea Institute of Geology Mining and Materials, Taejon (Korea, Republic of)

    1997-12-01

    Tomography is widely used as imaging method for determining subsurface structure. Among the reconstruction algorithms for tomographic imaging, travel time tomography is almost applied to imaging subsurface. But isolated small body comparable with the wavelength could not be well recognized by travel time tomography. Other tomographic method are need to improve the imaging process. In the study of this year, diffraction tomography was investigated. The theory for diffraction tomography is based on the 1st-order Born approximation. Multisource holography, which is similar to Kirchihoff migration, is compared with diffraction tomography. To improve 1st-order Born diffraction tomography, two kinds of filter designed from multisource holography and 2-D green function, respectively, applied on the reconstructed image. The algorithm was tested for the numerical modeling data of which algorithm consists of the analytic computation of radar signal in transmitter and receiver regions and 2-D FDM scheme for the propagation of electromagnetic waves in media. The air-filled cavity model to show a typical diffraction pattern was applied to diffraction tomography imaging, and the result shows accurate location and area of cavity. But the calculated object function is not well matched the real object function, because the air-filled cavity model is not satisfied week scattered inhomogeneity for 1st born approximation, and the error term is included in estimating source wavelet from received signals. In spite of the object function error, the diffraction tomography assist for interpretation of subsurface as if conducted with travel time tomography. And the fracture model was tested, 1st born diffraction tomographic image is poor because of limited view angle coverage and violation of week scatter assumption, but the filtered image resolve the fracture somewhat better. The tested diffraction tomography image confirms effectiveness of filter for enhancing resolution. (author). 14

  16. Results of the Italian neuART project

    International Nuclear Information System (INIS)

    Re, A; Albertin, F; Brancaccio, R; Cotto, G; Dughera, G; Durisi, E; Ferrarese, W; Lo Giudice, A; Mereu, P; Mila, G; Pastrone, N; Prino, F; Bortolin, C; Corsi, J; Buscaglia, P; Giovagnoli, A; Grassi, N; Nervo, M; Gambaccini, M; Petrucci, F

    2012-01-01

    The neu A RT project aims at developing state of the art transmission imaging and computed tomography techniques, applied to art objects, by using neutrons as well as more conventional X-rays. In this paper a facility for digital X-ray radiography of large area paintings on canvas or wooden panels and for the X-ray tomography of large size wooden artifacts, recently installed in a protected area, is presented. The results of a K-edge radiography facility that will soon be installed in the same area are also shown.

  17. Cardiac blood pool emission tomography

    International Nuclear Information System (INIS)

    Itti, R.; Philippe, L.; Lorgeron, J.M.; Charbonnier, B.; Raynaud, P.; Brochier, M.

    1983-01-01

    After blood pool labeling using technetium-99m, a series of cardiac pictures is acquired during the rotation of a gamma-camera about the patient. Computer processing leads to reconstruction of various tomographic slices from the original planar projection. Electrocardiographic gating selects the different phases of the cardiac cycle. Individual slices through the left ventricular region are added in order to provide ''thick'' slices on which global and regional parameters of the left ventricular function can be determined. Due to the proportionality existing between count rates and labeled blood volumes, any geometrical model can be avoided. The delineation of regions of interest for count integration is made easier due to the absence of superimposition of structures; no correction for background is necessary. Tomography thus appears to be more consistent and more accurate than the classical methods using planar projections. In addition, right ventricular morphological and kinetic studies can be performed in the same conditions as for the left ventricle [fr

  18. Neutron stimulated emission computed tomography: Background corrections

    International Nuclear Information System (INIS)

    Floyd, Carey E.; Sharma, Amy C.; Bender, Janelle E.; Kapadia, Anuj J.; Xia, Jessie Q.; Harrawood, Brian P.; Tourassi, Georgia D.; Lo, Joseph Y.; Kiser, Matthew R.; Crowell, Alexander S.; Pedroni, Ronald S.; Macri, Robert A.; Tajima, Shigeyuki; Howell, Calvin R.

    2007-01-01

    Neutron stimulated emission computed tomography (NSECT) is an imaging technique that provides an in-vivo tomographic spectroscopic image of the distribution of elements in a body. To achieve this, a neutron beam illuminates the body. Nuclei in the body along the path of the beam are stimulated by inelastic scattering of the neutrons in the beam and emit characteristic gamma photons whose unique energy identifies the element. The emitted gammas are collected in a spectrometer and form a projection intensity for each spectral line at the projection orientation of the neutron beam. Rotating and translating either the body or the beam will allow a tomographic projection set to be acquired. Images are reconstructed to represent the spatial distribution of elements in the body. Critical to this process is the appropriate removal of background gamma events from the spectrum. Here we demonstrate the equivalence of two background correction techniques and discuss the appropriate application of each

  19. Development of sealed sample containers and high resolution micro-tomography

    Energy Technology Data Exchange (ETDEWEB)

    Uesugi, Kentaro, E-mail: ueken@spring8.or.jp; Takeuchi, Akihisa; Suzuki, Yoshio [Japan synchrotron radiation research institute, JASRI/SPring-8 Kouto 1-1-1, Sayo, Hyogo 679-5198 Japan (Japan); Uesugi, Masayuki [Japan Aerospace Exploration Agency (ISAS/JAXA), Sagamihara, Kanagawa 252-5210 (Japan); Hamada, Hiroshi [NTT Advanced technology Corporation, Atsugi, Kanagawa 243-0124 (Japan)

    2016-01-28

    A sample container and a high resolution micro-tomography system have been developed at BL47XU at SPring-8. The container is made of a SiN membrane in a shape of truncated pyramid, which makes it possible to exclude oxygen and moisture in the air. The sample rotation stage for tomography is set downward to keep the sample in the container without any glue. The spatial resolution and field of view are 300 nm and 110 μm using a Fresnel zone plate objective with an outermost zone width of 100 nm at 8 keV, respectively. The scan time is about 20 minutes for 1800 projections. A 3-D image of an asteroid particle was successfully obtained without adhesive and contamination.

  20. Ground-glass opacity: High-resolution computed tomography and 64-multi-slice computed tomography findings comparison

    International Nuclear Information System (INIS)

    Sergiacomi, Gianluigi; Ciccio, Carmelo; Boi, Luca; Velari, Luca; Crusco, Sonia; Orlacchio, Antonio; Simonetti, Giovanni

    2010-01-01

    Objective: Comparative evaluation of ground-glass opacity using conventional high-resolution computed tomography technique and volumetric computed tomography by 64-row multi-slice scanner, verifying advantage of volumetric acquisition and post-processing technique allowed by 64-row CT scanner. Methods: Thirty-four patients, in which was assessed ground-glass opacity pattern by previous high-resolution computed tomography during a clinical-radiological follow-up for their lung disease, were studied by means of 64-row multi-slice computed tomography. Comparative evaluation of image quality was done by both CT modalities. Results: It was reported good inter-observer agreement (k value 0.78-0.90) in detection of ground-glass opacity with high-resolution computed tomography technique and volumetric Computed Tomography acquisition with moderate increasing of intra-observer agreement (k value 0.46) using volumetric computed tomography than high-resolution computed tomography. Conclusions: In our experience, volumetric computed tomography with 64-row scanner shows good accuracy in detection of ground-glass opacity, providing a better spatial and temporal resolution and advanced post-processing technique than high-resolution computed tomography.

  1. Improving Public Schools through the Dissent of Parents: Opting out of Tests, Demanding Alternative Curricula, Invoking Parent Trigger Laws, and Withdrawing Entirely

    Science.gov (United States)

    Stitzlein, Sarah M.

    2015-01-01

    Some parents and caregivers, frustrated by low academic performance of their local school, emphasis on testing, or the content of the curriculum, have worked independently or formed parent groups to speak out and demand improvements. Parents and families enact solutions such as opting out of tests, developing alternative curricula, invoking parent…

  2. A development of super computed tomography scanner for industrial column investigation

    International Nuclear Information System (INIS)

    Abdul Quddoos Abu Bakar; Jaafar Abdullah; Ismail Mustapha

    2004-01-01

    Computed Tomography (CT) scanner is a desired devices on create images of internal structure of unrecognized object. The formation of a CT images is a distinct three phase process. The scanning phase produces data, but not an image. Then, reconstruction phase processes the acquired data and forms a digital image. The visible and displayed analog image is produced by the digital to analog conversation phase. In this case, there are adjustable factors associated with each of these phases that can have an effect on the characteristics and quantity of the image. In term on this project of column scanning, during the scanning phase a fan-shaped gamma ray beam is scanned around the column. The amount of gamma radiation that penetrates the column along each individual ray (pathway) through the column is measured by the detectors that intercept the gamma ray beam after it passes through the column.This project of Super Computed Tomography (CT) is develop to reconstruct and redesign the mechanical parts and equipment to suits the purpose of the industrial column investigation in the region. (Author)

  3. Projection radiography. Chapter 6

    Energy Technology Data Exchange (ETDEWEB)

    Poletti, J. L. [UNITEC Institute of Technology, Auckland (New Zealand)

    2014-09-15

    In its simplest form, X ray imaging is the collection of attenuation shadows that are projected from an ideal X ray point source on to an image receptor. This simple form is true for all X ray imaging modalities, including complex ones that involve source and receptor movement, such as computed tomography (CT). This simplified view, however, is made vastly more complex by the non-ideal point source, by the consequences of projecting a 3-D object on to a 2-D detector and by the presence of scattered radiation, generated within the patient, which will degrade any image that is captured.

  4. Discrete tomography in an in vivo small animal bone study.

    Science.gov (United States)

    Van de Casteele, Elke; Perilli, Egon; Van Aarle, Wim; Reynolds, Karen J; Sijbers, Jan

    2018-01-01

    This study aimed at assessing the feasibility of a discrete algebraic reconstruction technique (DART) to be used in in vivo small animal bone studies. The advantage of discrete tomography is the possibility to reduce the amount of X-ray projection images, which makes scans faster and implies also a significant reduction of radiation dose, without compromising the reconstruction results. Bone studies are ideal for being performed with discrete tomography, due to the relatively small number of attenuation coefficients contained in the image [namely three: background (air), soft tissue and bone]. In this paper, a validation is made by comparing trabecular bone morphometric parameters calculated from images obtained by using DART and the commonly used standard filtered back-projection (FBP). Female rats were divided into an ovariectomized (OVX) and a sham-operated group. In vivo micro-CT scanning of the tibia was done at baseline and at 2, 4, 8 and 12 weeks after surgery. The cross-section images were reconstructed using first the full set of projection images and afterwards reducing them in number to a quarter and one-sixth (248, 62, 42 projection images, respectively). For both reconstruction methods, similar changes in morphometric parameters were observed over time: bone loss for OVX and bone growth for sham-operated rats, although for DART the actual values were systematically higher (bone volume fraction) or lower (structure model index) compared to FBP, depending on the morphometric parameter. The DART algorithm was, however, more robust when using fewer projection images, where the standard FBP reconstruction was more prone to noise, showing a significantly bigger deviation from the morphometric parameters obtained using all projection images. This study supports the use of DART as a potential alternative method to FBP in X-ray micro-CT animal studies, in particular, when the number of projections has to be drastically minimized, which directly reduces

  5. Simulated annealing image reconstruction for positron emission tomography

    Energy Technology Data Exchange (ETDEWEB)

    Sundermann, E; Lemahieu, I; Desmedt, P [Department of Electronics and Information Systems, University of Ghent, St. Pietersnieuwstraat 41, B-9000 Ghent, Belgium (Belgium)

    1994-12-31

    In Positron Emission Tomography (PET) images have to be reconstructed from moisy projection data. The noise on the PET data can be modeled by a Poison distribution. In this paper, we present the results of using the simulated annealing technique to reconstruct PET images. Various parameter settings of the simulated annealing algorithm are discussed and optimized. The reconstructed images are of good quality and high contrast, in comparison to other reconstruction techniques. (authors). 11 refs., 2 figs.

  6. Optimization of soft X-ray tomography on the COMPASS tokamak

    Czech Academy of Sciences Publication Activity Database

    Imríšek, Martin; Mlynář, Jan; Löffelmann, Viktor; Weinzettl, Vladimír; Odstrčil, T.; Odstrčil, M.; Tomeš, Matěj

    2016-01-01

    Roč. 61, č. 4 (2016), s. 403-408 ISSN 0029-5922. [Summer School of Plasma Diagnostics PhDiaFusion 2015: “Soft X-ray Diagnostics for Fusion Plasma”. Bezmiechowa, 16.06.2015-20.06.2015] R&D Projects: GA MŠk(CZ) LM2011021; GA MŠk LG14002; GA MŠk(CZ) 8D15001 EU Projects: European Commission(XE) 633053 - EUROfusion Institutional support: RVO:61389021 Keywords : soft X-ray * tomography * Tikhonov regularization * tokamak Subject RIV: BL - Plasma and Gas Discharge Physics Impact factor: 0.760, year: 2016 http://www.ichtj.waw.pl/nukleonikaa/?p=1256

  7. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... Physician Resources Professions Site Index A-Z Computed Tomography (CT) - Head Computed tomography (CT) of the head uses special x-ray ... What is CT Scanning of the Head? Computed tomography, more commonly known as a CT or CAT ...

  8. Blur kernel estimation with algebraic tomography technique and intensity profiles of object boundaries

    Science.gov (United States)

    Ingacheva, Anastasia; Chukalina, Marina; Khanipov, Timur; Nikolaev, Dmitry

    2018-04-01

    Motion blur caused by camera vibration is a common source of degradation in photographs. In this paper we study the problem of finding the point spread function (PSF) of a blurred image using the tomography technique. The PSF reconstruction result strongly depends on the particular tomography technique used. We present a tomography algorithm with regularization adapted specifically for this task. We use the algebraic reconstruction technique (ART algorithm) as the starting algorithm and introduce regularization. We use the conjugate gradient method for numerical implementation of the proposed approach. The algorithm is tested using a dataset which contains 9 kernels extracted from real photographs by the Adobe corporation where the point spread function is known. We also investigate influence of noise on the quality of image reconstruction and investigate how the number of projections influence the magnitude change of the reconstruction error.

  9. Seismic tomography Technology for the Water Infiltration Experiment

    International Nuclear Information System (INIS)

    Descour, J.

    2001-01-01

    NSA Engineering, Inc., conducted seismic tomography surveys in Niche No.3 in the Exploratory Studies Facility (ESF), Yucca Mountain, Nevada, and Alcove No.8 in the Enhanced Characterization of the Repository Block (ECRB) cross drift as part of the Infiltration Experiment being conducted in Niche No.3. NSA Engineering is a direct support contractor to the Yucca Mountain Project. This report documents the work performed from August 14 through 30, 2000, prior to the beginning of the infiltration experiment. The objective of the seismic tomography survey was to investigate the flow path of water between access drifts and more specifically to (Kramer 2000): (1) Conduct a baseline seismic tomography survey prior to the infiltration experiment; (2) Produce 2-D and 3-D tomographic images of the rock volume between Alcove No.8 and Niche No.3; (3) Correlate tomography results with published structural and lithological features, and with other geophysical data such as ground penetrating radar (GPR); and (4) Results of this survey will form a baseline with which to compare subsequent changes to the rock mass. These changes may be as a result of the water infiltration tests that could be conducted in Alcove No.8 in 2001. The scope of this reported work is to use the velocity tomograms to: (a) assess the structures and lithologic features within the surveyed area and/or volume between the two access drifts; and (b) provide information on the structural state of the rock mass as inferred by the velocity signatures of the rock prior to the beginning of the infiltration experiment

  10. Initial evaluation of image performance of a 3-D x-ray system: phantom-based comparison of 3-D tomography with conventional computed tomography.

    Science.gov (United States)

    Benz, Robyn Melanie; Garcia, Meritxell Alzamora; Amsler, Felix; Voigt, Johannes; Fieselmann, Andreas; Falkowski, Anna Lucja; Stieltjes, Bram; Hirschmann, Anna

    2018-01-01

    Phantom-based initial performance assessment of a prototype three-dimensional (3-D) x-ray system and comparison of 3-D tomography with computed tomography (CT) were proposed. A 3-D image quality phantom was scanned with a prototype version of 3-D cone-beam CT imaging implemented on a twin robotic x-ray system using three trajectories (163 deg = table, 188 deg = upright, and 200 deg = side), six tube voltages (60, 70, 81, 90, 100, and 121 kV), and four detector doses (0.348, 0.696, 1.740, and [Formula: see text]). CT was obtained with a clinical protocol. Spatial resolution (line pairs/cm) and soft-tissue-contrast resolution were assessed by two independent readers. Radiation dose was assessed. Descriptive and analysis of variance (ANOVA) ([Formula: see text]) were performed. With 3-D tomography, a maximum of 16 lp/cm was visible and best soft-tissue-contrast resolution was 2 mm at 30 Hounsfield units (HU) for 160 projections. With CT, 10 lp/cm was visible and soft-tissue-contrast resolution was 4 mm at 20 HU. The upright trajectory yielded significantly better spatial resolution and soft tissue contrast, and the side trajectory yielded significantly higher soft tissue contrast than the table trajectory ([Formula: see text]). Radiation dose was higher in 3-D tomography (45 to 704 mGycm) than CT (44 mGycm). Three-dimensional tomography renders overall equal or higher spatial resolution and comparable soft tissue contrast to CT for medium- and high-dose protocols in the side and upright trajectories, but with higher radiation doses.

  11. Quantifying the debonding of inclusions through tomography and computational homology.

    Energy Technology Data Exchange (ETDEWEB)

    Lu, Wei-Yang; Johnson, George C. (University of California, Berkeley, Berkeley, CA); Mota, Alejandro; Foulk, James W., III; Jin, Huiqing

    2010-09-01

    This report describes a Laboratory Directed Research and Development (LDRD) project to use of synchrotron-radiation computed tomography (SRCT) data to determine the conditions and mechanisms that lead to void nucleation in rolled alloys. The Advanced Light Source (ALS) at Lawrence Berkeley National Laboratory (LBNL) has provided SRCT data of a few specimens of 7075-T7351 aluminum plate (widely used for aerospace applications) stretched to failure, loaded in directions perpendicular and parallel to the rolling direction. The resolution of SRCT data is 900nm, which allows elucidation of the mechanisms governing void growth and coalescence. This resolution is not fine enough, however, for nucleation. We propose the use statistics and image processing techniques to obtain sub-resolution scale information from these data, and thus determine where in the specimen and when during the loading program nucleation occurs and the mechanisms that lead to it. Quantitative analysis of the tomography data, however, leads to the conclusion that the reconstruction process compromises the information obtained from the scans. Alternate, more powerful reconstruction algorithms are needed to address this problem, but those fall beyond the scope of this project.

  12. Iterative methods for dose reduction and image enhancement in tomography

    Science.gov (United States)

    Miao, Jianwei; Fahimian, Benjamin Pooya

    2012-09-18

    A system and method for creating a three dimensional cross sectional image of an object by the reconstruction of its projections that have been iteratively refined through modification in object space and Fourier space is disclosed. The invention provides systems and methods for use with any tomographic imaging system that reconstructs an object from its projections. In one embodiment, the invention presents a method to eliminate interpolations present in conventional tomography. The method has been experimentally shown to provide higher resolution and improved image quality parameters over existing approaches. A primary benefit of the method is radiation dose reduction since the invention can produce an image of a desired quality with a fewer number projections than seen with conventional methods.

  13. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... Physician Resources Professions Site Index A-Z Computed Tomography (CT) - Sinuses Computed tomography (CT) of the sinuses uses special x-ray equipment ... story here Images × Image Gallery Patient undergoing computed tomography (CT) scan. View full size with caption Pediatric Content ...

  14. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... Physician Resources Professions Site Index A-Z Computed Tomography (CT) - Head Computed tomography (CT) of the head uses special x-ray equipment ... story here Images × Image Gallery Patient undergoing computed tomography (CT) scan. View full size with caption Pediatric Content ...

  15. Six-dimensional real and reciprocal space small-angle X-ray scattering tomography.

    Science.gov (United States)

    Schaff, Florian; Bech, Martin; Zaslansky, Paul; Jud, Christoph; Liebi, Marianne; Guizar-Sicairos, Manuel; Pfeiffer, Franz

    2015-11-19

    When used in combination with raster scanning, small-angle X-ray scattering (SAXS) has proven to be a valuable imaging technique of the nanoscale, for example of bone, teeth and brain matter. Although two-dimensional projection imaging has been used to characterize various materials successfully, its three-dimensional extension, SAXS computed tomography, poses substantial challenges, which have yet to be overcome. Previous work using SAXS computed tomography was unable to preserve oriented SAXS signals during reconstruction. Here we present a solution to this problem and obtain a complete SAXS computed tomography, which preserves oriented scattering information. By introducing virtual tomography axes, we take advantage of the two-dimensional SAXS information recorded on an area detector and use it to reconstruct the full three-dimensional scattering distribution in reciprocal space for each voxel of the three-dimensional object in real space. The presented method could be of interest for a combined six-dimensional real and reciprocal space characterization of mesoscopic materials with hierarchically structured features with length scales ranging from a few nanometres to a few millimetres--for example, biomaterials such as bone or teeth, or functional materials such as fuel-cell or battery components.

  16. Anti-3-[(18)F]FACBC positron emission tomography-computerized tomography and (111)In-capromab pendetide single photon emission computerized tomography-computerized tomography for recurrent prostate carcinoma: results of a prospective clinical trial.

    Science.gov (United States)

    Schuster, David M; Nieh, Peter T; Jani, Ashesh B; Amzat, Rianot; Bowman, F Dubois; Halkar, Raghuveer K; Master, Viraj A; Nye, Jonathon A; Odewole, Oluwaseun A; Osunkoya, Adeboye O; Savir-Baruch, Bital; Alaei-Taleghani, Pooneh; Goodman, Mark M

    2014-05-01

    We prospectively evaluated the amino acid analogue positron emission tomography radiotracer anti-3-[(18)F]FACBC compared to ProstaScint® ((111)In-capromab pendetide) single photon emission computerized tomography-computerized tomography to detect recurrent prostate carcinoma. A total of 93 patients met study inclusion criteria who underwent anti-3-[(18)F]FACBC positron emission tomography-computerized tomography plus (111)In-capromab pendetide single photon emission computerized tomography-computerized tomography for suspected recurrent prostate carcinoma within 90 days. Reference standards were applied by a multidisciplinary board. We calculated diagnostic performance for detecting disease. In the 91 of 93 patients with sufficient data for a consensus on the presence or absence of prostate/bed disease anti-3-[(18)F]FACBC had 90.2% sensitivity, 40.0% specificity, 73.6% accuracy, 75.3% positive predictive value and 66.7% negative predictive value compared to (111)In-capromab pendetide with 67.2%, 56.7%, 63.7%, 75.9% and 45.9%, respectively. In the 70 of 93 patients with a consensus on the presence or absence of extraprostatic disease anti-3-[(18)F]FACBC had 55.0% sensitivity, 96.7% specificity, 72.9% accuracy, 95.7% positive predictive value and 61.7% negative predictive value compared to (111)In-capromab pendetide with 10.0%, 86.7%, 42.9%, 50.0% and 41.9%, respectively. Of 77 index lesions used to prove positivity histological proof was obtained in 74 (96.1%). Anti-3-[(18)F]FACBC identified 14 more positive prostate bed recurrences (55 vs 41) and 18 more patients with extraprostatic involvement (22 vs 4). Anti-3-[(18)F]FACBC positron emission tomography-computerized tomography correctly up-staged 18 of 70 cases (25.7%) in which there was a consensus on the presence or absence of extraprostatic involvement. Better diagnostic performance was noted for anti-3-[(18)F]FACBC positron emission tomography-computerized tomography than for (111)In-capromab pendetide single

  17. A rapid parallelization of cone-beam projection and back-projection operator based on texture fetching interpolation

    Science.gov (United States)

    Xie, Lizhe; Hu, Yining; Chen, Yang; Shi, Luyao

    2015-03-01

    Projection and back-projection are the most computational consuming parts in Computed Tomography (CT) reconstruction. Parallelization strategies using GPU computing techniques have been introduced. We in this paper present a new parallelization scheme for both projection and back-projection. The proposed method is based on CUDA technology carried out by NVIDIA Corporation. Instead of build complex model, we aimed on optimizing the existing algorithm and make it suitable for CUDA implementation so as to gain fast computation speed. Besides making use of texture fetching operation which helps gain faster interpolation speed, we fixed sampling numbers in the computation of projection, to ensure the synchronization of blocks and threads, thus prevents the latency caused by inconsistent computation complexity. Experiment results have proven the computational efficiency and imaging quality of the proposed method.

  18. Development of axial tomography technique for the study of steam explosion

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Jae Young; Seo, S. W.; You, S. [Handong Golbal Univ., Pohang (Korea, Republic of)

    2006-05-15

    In this report, axial tomography applying to steam explosion is implemented. When steam explosion experiment is performed, we have seen the difficulty with physical modeling due to the complex phenomena of generated steam, propagation of shock wave and bubble breakup and coalescence. Hence, the uncertainty due to these phenomena is occurred. The fast and global measurement of the steam distribution is imperative to understand the complex phenomena performed during the steam explosion, KAERI have developed the fast and global measuring instrument to monitor such phenomena of axial steam distribution. Generally, X-ray is used as measuring method, but this method is very expensive and has limited measurement area. So we need new method that can substitute X-ray method and in this research, ECT method is replaced. The research is performed dividing within two parts: Software and Hardware. In the software part, the electric field analysis code and algorithm for inverse projection were developed. And, in the hardware part, capacitance measurement circuit is developed to measure up to fF level. Operable axial tomography was analyzed with concept design of axial tomography appropriate to steam explosion accident and analysis code for axial electric field analysis and inverse algorithm were developed, moreover, designing signal analysis system for axial tomography was performed.

  19. Monitoring an in-situ uranium mining site with radio tomography

    International Nuclear Information System (INIS)

    Stolarczyk, L.; Mondt, W.; Mays, W.

    1991-01-01

    A field test site has been developed to monitor ground water restoration in an in-situ uranium mining project. Uranium deposited in a shallow buried fluvial sandstone channel (aquifer) has been mined by the injection and recovery of ammonia carbonate leachant from a constellation of drillholes. Ground water restoration is accomplished by injecting clean water into a well and recovering contaminated water from companion wells. The restoration process exchanges clean water for contaminated water in the aquifer. The stratigraphic cross section of the aquifer and the hydro-dynamics of the ground water restoration process is currently being investigated with radio wave tomography. Crosshole continuous wave (CW) radio signals are propagated from a well to a second well in the constellation of drillholes. The magnitude and phase of the radio wave are measured in the second well with Radio Imaging Method (RIM) instruments. The acquired data is processed in tomography algorithms to determine the EM wave propagation constants (attenuation rate [α] and phase constant [β]) in each pixel that covers the image plane between wells. The in-situ electrical conductivity values are computed from the pixel propagation constants. Contaminated ground water causes the conductivity of the local zone of the aquifer to increase. This paper describes the initial radio tomography mapping of the deposit lithology and compares radio tomography and E log conductivity values

  20. The Effect of Veneer Layers on the Bending Shear Strength and Delamination of Laminated Veneer Lumber (LVL) from Oil Palm Trunk (OPT)

    Science.gov (United States)

    Jamaludin, M. A.; Nordin, K.; Bahari, S. A.; Ahmad, M.

    2010-03-01

    The aim of this study was to evaluate the effects of the number of veneer layers on the bending shear strength and delamination of Laminated Veneer Lumber (LVL) from oil palm trunk (OPT). Five (5), Six (6) and Seven (7) veneer layers of OPT LVL were manufactured. The dimension of the boards was 45 cm by 45 cm by 1.9 cm. The boards were hot pressed for 13 minutes at a pressure of 31 kgf per m2. Urea formaldehyde (UF) supplied by a local adhesive manufacturer was used as the binder for the boards. The bending shear tests consisted of the edgewise and flatwise tests, whereas the delamination test consisted of the cold and hot water boil tests. The preparation of the test specimens and tests set-up was in accordance to the Japanese Standards, JAS-1991 [1]. Six replications were used for each test. The results were analyzed by Analysis of Variance (ANOVA) using the Duncan's Multiple Range Test to test for significant differences. The results indicated that as the number of layers increased the strength also increased. All the boards passed the standard. The difference in strength between the different types of samples was significant at 95 percent confidence level. Bending shear failures were primarily in the veneers. It is possible to use the boards as light weight interior building and furniture components. Over the years, the supply of quality timber resources from the natural forest has decrease as the wood-based industry experienced rapid growth. The supply of rubberwood for the furniture industry is also decreasing as a result of increase latex price. Accordingly, OPT LVL can be an alternative or supplementary raw material for the wood-based industry.

  1. Comparison of two ring artefact removal filters used for neutron tomography reconstruction

    International Nuclear Information System (INIS)

    Vontobel, P.

    2007-01-01

    Full text of publication follows: The reduction of ring artefacts in transmission tomography reconstruction, by filtering sino-grams, is a common practice for most radiation modalities. Using simulated and measured neutron transmission data, an analysis of two ring artefact suppression schemes is given. The choice of the ring filtering parameters has to take the noise characteristics of the measured raw projection data into account. Introduction The appearance of ring artefacts in transmission tomography data is quite common. They are due to deficiencies in the measured projections and show as vertical lines in the sinogram representation of all projections of a single slice. A vertical line in the sinogram is due to a single pixel or a group of n pixels on the detector, which is less or more sensitive than the average pixel and shows even after flat-field correction. Most annoying ring artefacts are due to partly dead pixels, which cannot be identified easily on the projection images. Their effect only show in the sinogram or later on the reconstructed slice images. Therefore ring artefact mitigation starts with the analysis of sinogram images or analysis of reconstructed slices. Analysis of two ring filtering algorithms: The first ring filtering method sums first sinogram rows (i.e. over all angles) and divides it by the number of rows (ave) and generate a smoothed version of this sum (smoothing width 3,5,7,9 pixels). The difference diff = ave - smooth(ave) is then subtracted from each row. This is a very simple and efficient correction scheme. The second method relies on morphological filtering the sinogram i.e. using a combination of a morphological 'Top hat' and a 'Bot hat' operation on the data. A filtering threshold is determined depending on the number of detected lines in the sinogram. Summary and conclusion: Using simulated an measured neutron transmission data two ring filtering algorithms are evaluated. A careful choice of filtering parameters is

  2. COST EFFECTIVE AND HIGH RESOLUTION SUBSURFACE CHARACTERIZATION USING HYDRAULIC TOMOGRAPHY

    Science.gov (United States)

    2017-08-01

    objective of this project is to provide the DoD and its remediation contractors with the HT technology for delineating the spatial distribution of...STATEMENT Approved for public release; distribution is unlimited 13. SUPPLEMENTARY NOTES 14. ABSTRACT Hydraulic Tomography ( HT ) is a high-resolution...performance of subsurface remedial actions at environmental sites. The good technical performance and cost-effectiveness of HT have been demonstrated in

  3. Computed tomography

    International Nuclear Information System (INIS)

    Wells, P.; Davis, J.; Morgan, M.

    1994-01-01

    X-ray or gamma-ray transmission computed tomography (CT) is a powerful non-destructive evaluation (NDE) technique that produces two-dimensional cross-sectional images of an object without the need to physically section it. CT is also known by the acronym CAT, for computerised axial tomography. This review article presents a brief historical perspective on CT, its current status and the underlying physics. The mathematical fundamentals of computed tomography are developed for the simplest transmission CT modality. A description of CT scanner instrumentation is provided with an emphasis on radiation sources and systems. Examples of CT images are shown indicating the range of materials that can be scanned and the spatial and contrast resolutions that may be achieved. Attention is also given to the occurrence, interpretation and minimisation of various image artefacts that may arise. A final brief section is devoted to the principles and potential of a range of more recently developed tomographic modalities including diffraction CT, positron emission CT and seismic tomography. 57 refs., 2 tabs., 14 figs

  4. Equiripple Digital Filter in Quadrature Mirror Filter Banks for Nuclear Magnetic Tomography

    Czech Academy of Sciences Publication Activity Database

    Gescheidtová, E.; Kubásek, R.; Smékal, Z.; Bartušek, Karel

    2007-01-01

    Roč. 37, č. 1 (2007), s. 141-149 ISSN 1738-6438 R&D Projects: GA ČR(CZ) GA102/07/0389; GA ČR(CZ) GA102/07/1086 Institutional research plan: CEZ:AV0Z20650511 Keywords : wavelet transform * digital filter * MR tomography Subject RIV: JA - Electronics ; Optoelectronics, Electrical Engineering

  5. Tomography system having an ultrahigh-speed processing unit

    International Nuclear Information System (INIS)

    Brunnett, C.J.; Gerth, V.W. Jr.

    1977-01-01

    A transverse section tomography system has an ultrahigh-speed data processing unit for performing back projection and updating. An x-ray scanner directs x-ray beams through a planar section of a subject from a sequence of orientations and positions. The data processing unit includes a scan storage section for retrievably storing a set of filtered scan signals in scan storage locations corresponding to predetermined beam orientations. An array storage section is provided for storing image signals as they are generated

  6. A general exact method for synthesizing parallel-beam projections from cone-beam projections via filtered backprojection

    International Nuclear Information System (INIS)

    Li Liang; Chen Zhiqiang; Xing Yuxiang; Zhang Li; Kang Kejun; Wang Ge

    2006-01-01

    In recent years, image reconstruction methods for cone-beam computed tomography (CT) have been extensively studied. However, few of these studies discussed computing parallel-beam projections from cone-beam projections. In this paper, we focus on the exact synthesis of complete or incomplete parallel-beam projections from cone-beam projections. First, an extended central slice theorem is described to establish a relationship between the Radon space and the Fourier space. Then, data sufficiency conditions are proposed for computing parallel-beam projection data from cone-beam data. Using these results, a general filtered backprojection algorithm is formulated that can exactly synthesize parallel-beam projection data from cone-beam projection data. As an example, we prove that parallel-beam projections can be exactly synthesized in an angular range in the case of circular cone-beam scanning. Interestingly, this angular range is larger than that derived in the Feldkamp reconstruction framework. Numerical experiments are performed in the circular scanning case to verify our method

  7. Crosshole investigations - short and medium range seismic tomography

    International Nuclear Information System (INIS)

    Cosma, C.

    1987-02-01

    Seismic tomographic tests were conducted as a part of the Crosshole Investigations program of the Stripa Project. The aim has been to study if it is possible to detect by seismic tomography major fracture zones and determine their dimensions and orientation. The analysis was based on both compressional (P) and transversal (S) waves. The Young's modulus has been also calculated for a sub-set of measurements as a cross check for the P and S wave velocities. The experimental data was collected at the crosshole site in the Stripa mine during 1984-1985. A down-the-hole impact source was used together with triaxial detectors and a digital seismograph. Five tomographic sections were obtained. The number of records per section was appr. 250. Measurements were done down to 200 m depth in all boreholes. The main conclusion is that it is possible to detect major fracture zones by seismic tomography. Their position and orientation can also be estimated. (orig./HP)

  8. 3D particle tracking velocimetry using dynamic discrete tomography for plasma physics applications

    DEFF Research Database (Denmark)

    Moseev, Dmitry; Alpers, Andreas; Gritzmann, Peter

    2013-01-01

    tomography algorithm is efficient for data from two projection directions and exact. The non-uniqueness can be detected and tracked individually. The algorithm performance is proportional to N3 on average where N is the number of particles in the reconstruction. There is a room for further improvement...

  9. Single photon emission tomography

    International Nuclear Information System (INIS)

    Buvat, Irene

    2011-09-01

    The objective of this lecture is to present the single photon emission computed tomography (SPECT) imaging technique. Content: 1 - Introduction: anatomic, functional and molecular imaging; Principle and role of functional or molecular imaging; 2 - Radiotracers: chemical and physical constraints, main emitters, radioisotopes production, emitters type and imaging techniques; 3 - Single photon emission computed tomography: gamma cameras and their components, gamma camera specifications, planar single photon imaging characteristics, gamma camera and tomography; 4 - Quantification in single photon emission tomography: attenuation, scattering, un-stationary spatial resolution, partial volume effect, movements, others; 5 - Synthesis and conclusion

  10. Self-adapting denoising, alignment and reconstruction in electron tomography in materials science

    Energy Technology Data Exchange (ETDEWEB)

    Printemps, Tony, E-mail: tony.printemps@cea.fr [Université Grenoble Alpes, F-38000 Grenoble (France); CEA, LETI, MINATEC Campus, F-38054 Grenoble (France); Mula, Guido [Dipartimento di Fisica, Università di Cagliari, Cittadella Universitaria, S.P. 8km 0.700, 09042 Monserrato (Italy); Sette, Daniele; Bleuet, Pierre; Delaye, Vincent; Bernier, Nicolas; Grenier, Adeline; Audoit, Guillaume; Gambacorti, Narciso; Hervé, Lionel [Université Grenoble Alpes, F-38000 Grenoble (France); CEA, LETI, MINATEC Campus, F-38054 Grenoble (France)

    2016-01-15

    An automatic procedure for electron tomography is presented. This procedure is adapted for specimens that can be fashioned into a needle-shaped sample and has been evaluated on inorganic samples. It consists of self-adapting denoising, automatic and accurate alignment including detection and correction of tilt axis, and 3D reconstruction. We propose the exploitation of a large amount of information of an electron tomography acquisition to achieve robust and automatic mixed Poisson–Gaussian noise parameter estimation and denoising using undecimated wavelet transforms. The alignment is made by mixing three techniques, namely (i) cross-correlations between neighboring projections, (ii) common line algorithm to get a precise shift correction in the direction of the tilt axis and (iii) intermediate reconstructions to precisely determine the tilt axis and shift correction in the direction perpendicular to that axis. Mixing alignment techniques turns out to be very efficient and fast. Significant improvements are highlighted in both simulations and real data reconstructions of porous silicon in high angle annular dark field mode and agglomerated silver nanoparticles in incoherent bright field mode. 3D reconstructions obtained with minimal user-intervention present fewer artefacts and less noise, which permits easier and more reliable segmentation and quantitative analysis. After careful sample preparation and data acquisition, the denoising procedure, alignment and reconstruction can be achieved within an hour for a 3D volume of about a hundred million voxels, which is a step toward a more routine use of electron tomography. - Highlights: • Goal: perform a reliable and user-independent 3D electron tomography reconstruction. • Proposed method: self-adapting denoising and alignment prior to 3D reconstruction. • Noise estimation and denoising are performed using wavelet transform. • Tilt axis determination is done automatically as well as projection alignment.

  11. Evaluation of iterative algorithms for tomography image reconstruction: A study using a third generation industrial tomography system

    Energy Technology Data Exchange (ETDEWEB)

    Velo, Alexandre F.; Carvalho, Diego V.; Alvarez, Alexandre G.; Hamada, Margarida M.; Mesquita, Carlos H., E-mail: afvelo@usp.br [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil)

    2017-07-01

    The greatest impact of the tomography technology currently occurs in medicine. The success is due to the human body presents standardized dimensions with well-established composition. These conditions are not found in industrial objects. In industry, there is much interest in using the tomography in order to know the inner of (1) the manufactured industrial objects or (2) the machines and their means of production. In these cases, the purpose of the tomography is to (a) control the quality of the final product and (b) to optimize production, contributing to the pilot phase of the projects and analyzing the quality of the means of production. This scan system is a non-destructive, efficient and fast method for providing sectional images of industrial objects and is able to show the dynamic processes and the dispersion of the materials structures within these objects. In this context, it is important that the reconstructed image presents a great spatial resolution with a satisfactory temporal resolution. Thus the algorithm to reconstruct the images has to meet these requirements. This work consists in the analysis of three different iterative algorithm methods, such Maximum Likelihood Estimation Method (MLEM), Maximum Likelihood Transmitted Method (MLTR) and Simultaneous Iterative Reconstruction Method (SIRT. The analysis consists on measurement of the contrast to noise ratio (CNR), the root mean square error (RMSE) and the Modulation Transfer Function (MTF), to know which algorithm fits better the conditions in order to optimize system. The algorithms and the image quality analysis were performed by the Matlab® 2013b. (author)

  12. Evaluation of iterative algorithms for tomography image reconstruction: A study using a third generation industrial tomography system

    International Nuclear Information System (INIS)

    Velo, Alexandre F.; Carvalho, Diego V.; Alvarez, Alexandre G.; Hamada, Margarida M.; Mesquita, Carlos H.

    2017-01-01

    The greatest impact of the tomography technology currently occurs in medicine. The success is due to the human body presents standardized dimensions with well-established composition. These conditions are not found in industrial objects. In industry, there is much interest in using the tomography in order to know the inner of (1) the manufactured industrial objects or (2) the machines and their means of production. In these cases, the purpose of the tomography is to (a) control the quality of the final product and (b) to optimize production, contributing to the pilot phase of the projects and analyzing the quality of the means of production. This scan system is a non-destructive, efficient and fast method for providing sectional images of industrial objects and is able to show the dynamic processes and the dispersion of the materials structures within these objects. In this context, it is important that the reconstructed image presents a great spatial resolution with a satisfactory temporal resolution. Thus the algorithm to reconstruct the images has to meet these requirements. This work consists in the analysis of three different iterative algorithm methods, such Maximum Likelihood Estimation Method (MLEM), Maximum Likelihood Transmitted Method (MLTR) and Simultaneous Iterative Reconstruction Method (SIRT. The analysis consists on measurement of the contrast to noise ratio (CNR), the root mean square error (RMSE) and the Modulation Transfer Function (MTF), to know which algorithm fits better the conditions in order to optimize system. The algorithms and the image quality analysis were performed by the Matlab® 2013b. (author)

  13. Specificity of the tomography implementation in electric arc domain - Validity in medical imaging

    International Nuclear Information System (INIS)

    Benech, Julie

    2008-01-01

    The aim of these works was to implement a new experimental method to characterize 3D thermal plasmas by emission spectroscopy. The method used is based on tomographic technique which is widely used in medical imaging nowadays. However, tomography that we have developed and applied to electric arc is specific as the number of accessible projections angles is strongly limited: 4 projections our case against basically 64 in medical imaging. The particularity of our experimental tomographic system is that measurements are resolved both spectrally and spatially. The spectral resolution is necessary to determine the temperature values from method based on atomic line intensity. The spatial resolution is needed to simultaneously acquire the whole width of the plasma and so to reconstruct a whole cross-section in only one acquisition. One of the principal objective was to realize the experimental system of four-view tomography for thermal plasmas. Thanks to this device, we showed that the characterization of non-axisymmetric plasma is possible and that it enables to reconstruct 3D temperature maps. Finally, our tomographic method is applied with medical imaging data acquired in SPECT (Single Photon Emission Computed Tomography). These tests allowed validating the use of our tomographic reconstruction technique in SPECT, particularly the used iterative algebraic algorithm and the limited-view configuration. (author) [fr

  14. Applications of X-ray Computed Tomography and Emission Computed Tomography

    International Nuclear Information System (INIS)

    Seletchi, Emilia Dana; Sutac, Victor

    2005-01-01

    Computed Tomography is a non-destructive imaging method that allows visualization of internal features within non-transparent objects such as sedimentary rocks. Filtering techniques have been applied to circumvent the artifacts and achieve high-quality images for quantitative analysis. High-resolution X-ray computed tomography (HRXCT) can be used to identify the position of the growth axis in speleothems by detecting subtle changes in calcite density between growth bands. HRXCT imagery reveals the three-dimensional variability of coral banding providing information on coral growth and climate over the past several centuries. The Nuclear Medicine imaging technique uses a radioactive tracer, several radiation detectors, and sophisticated computer technologies to understand the biochemical basis of normal and abnormal functions within the brain. The goal of Emission Computed Tomography (ECT) is to accurately determine the three-dimensional radioactivity distribution resulting from the radiopharmaceutical uptake inside the patient instead of the attenuation coefficient distribution from different tissues as obtained from X-ray Computer Tomography. ECT is a very useful tool for investigating the cognitive functions. Because of the low radiation doses associated with Positron Emission Tomography (PET), this technique has been applied in clinical research, allowing the direct study of human neurological diseases. (authors)

  15. Direct image reconstruction with limited angle projection data for computerized tomography

    International Nuclear Information System (INIS)

    Inouye, T.

    1980-01-01

    Discussions are made on the minimum angle range for projection data necessary to reconstruct the complete CT image. As is easily shown from the image reconstruction theorem, the lack of projection angle provides no data for the Fourier transformed function of the object on the corresponding angular directions, where the projections are missing. In a normal situation, the Fourier transformed function of an object image holds an analytic characteristic with respect to two-dimensional orthogonal parameters. This characteristic enables uniquely prolonging the function outside the obtained region employing a sort of analytic continuation with respect to both parameters. In the method reported here, an object pattern, which is confined within a finite range, is shifted to a specified region to have complete orthogonal function expansions without changing the projection angle directions. These orthogonal functions are analytically extended to the missing projection angle range and the whole function is determined. This method does not include any estimation process, whose effectiveness is often seriously jeopardized by the presence of a slight fluctuation component. Computer simulations were carried out to demonstrate the effectiveness of the method

  16. Adaptive zooming in X-ray computed tomography.

    Science.gov (United States)

    Dabravolski, Andrei; Batenburg, Kees Joost; Sijbers, Jan

    2014-01-01

    In computed tomography (CT), the source-detector system commonly rotates around the object in a circular trajectory. Such a trajectory does not allow to exploit a detector fully when scanning elongated objects. Increase the spatial resolution of the reconstructed image by optimal zooming during scanning. A new approach is proposed, in which the full width of the detector is exploited for every projection angle. This approach is based on the use of prior information about the object's convex hull to move the source as close as possible to the object, while avoiding truncation of the projections. Experiments show that the proposed approach can significantly improve reconstruction quality, producing reconstructions with smaller errors and revealing more details in the object. The proposed approach can lead to more accurate reconstructions and increased spatial resolution in the object compared to the conventional circular trajectory.

  17. Positron emission tomography of malignant tumours at head and neck. Evaluation of the diagnostic value of positron emission tomography by comparison with computed tomography

    International Nuclear Information System (INIS)

    Kettler, Nele

    2011-01-01

    Imaging methods for early, accurate diagnosis and aftercare of malignant growths is currently one of the most important research topics. The objective of this thesis is to evaluate the diagnostic value of FDG-positron emission tomography by comparison with computed tomography for patients with squamous cell carcinoma, malignant melanoma or sarcoma at head and neck. Measurement criteria are sensitivity and specificity. A retrospective evaluation of 100 examinations on 85 patients of University clinic Aachen was performed. The examination reports were supported by reports from histology, positron emission tomography and computed tomography. In each case, the histological results were assumed to provide a reliable benchmark. Sensitivity and specificity for the primary tumour site, metastatic lymphatic nodes and defined anatomic structures were compared across all patients. Comparisons were also performed on sub groups separated by gender, cancer type and the time and frequency at which tumours arose. The statistic analysis was done with MedCalc. Results: The results for sensitivity and specificity of the primary tumour site were 86.42% and 42.86%, and 64.71% and 66.07%, for positron emission tomography and computed tomography respectively. The results for the lymphatic nodes were 51.52% and 92.86% and 64.71% and 66.07%. When the constituent anatomic structures were evaluated separately, the specificity was significantly higher. The separation by gender showed no difference. Because the classification by tumor type resulted in samples that were of varying size, a comparison was difficult. For the diagnosis of primary tumours, the examination with positron emission tomography was superior, whereas computed tomography proved more effective for the diagnosis of recurrent tumours. For the diagnosis of the main tumour site, both methods were shown to be equally suitable. For the assessment of lymphatic nodes, positron emission tomography was superior to computed tomography

  18. Positron emission tomography

    International Nuclear Information System (INIS)

    Wienhard, K.; Heiss, W.D.

    1984-01-01

    The principles and selected clinical applications of positron emission tomography are described. In this technique a chemical compound is labeled with a positron emitting isotope and its biochemical pathway is traced by coincidence detection of the two annihilation photons. The application of the techniques of computed tomography allows to reconstruct the spatial distribution of the radioactivity within a subject. The 18 F-deoxyglucose method for quantitative measurement of local glucose metabolism is discussed in order to illustrate the possibilities of positron emission tomography to record physiological processes in vivo. (orig.) [de

  19. Simultaneous reconstruction of 3D refractive index, temperature, and intensity distribution of combustion flame by double computed tomography technologies based on spatial phase-shifting method

    Science.gov (United States)

    Guo, Zhenyan; Song, Yang; Yuan, Qun; Wulan, Tuya; Chen, Lei

    2017-06-01

    In this paper, a transient multi-parameter three-dimensional (3D) reconstruction method is proposed to diagnose and visualize a combustion flow field. Emission and transmission tomography based on spatial phase-shifted technology are combined to reconstruct, simultaneously, the various physical parameter distributions of a propane flame. Two cameras triggered by the internal trigger mode capture the projection information of the emission and moiré tomography, respectively. A two-step spatial phase-shifting method is applied to extract the phase distribution in the moiré fringes. By using the filtered back-projection algorithm, we reconstruct the 3D refractive-index distribution of the combustion flow field. Finally, the 3D temperature distribution of the flame is obtained from the refractive index distribution using the Gladstone-Dale equation. Meanwhile, the 3D intensity distribution is reconstructed based on the radiation projections from the emission tomography. Therefore, the structure and edge information of the propane flame are well visualized.

  20. An analysis of true- and false-positive results of vocal fold uptake in positron emission tomography-computed tomography imaging.

    Science.gov (United States)

    Seymour, N; Burkill, G; Harries, M

    2018-03-01

    Positron emission tomography-computed tomography with fluorine-18 fluorodeoxy-D-glucose has a major role in the investigation of head and neck cancers. Fluorine-18 fluorodeoxy-D-glucose is not a tumour-specific tracer and can also accumulate in benign pathology. Therefore, positron emission tomography-computed tomography scan interpretation difficulties are common in the head and neck, which can produce false-positive results. This study aimed to investigate patients detected as having abnormal vocal fold uptake on fluorine-18 fluorodeoxy-D-glucose positron emission tomography-computed tomography. Positron emission tomography-computed tomography scans were identified over a 15-month period where reports contained evidence of unilateral vocal fold uptake or vocal fold pathology. Patients' notes and laryngoscopy results were analysed. Forty-six patients were identified as having abnormal vocal fold uptake on positron emission tomography-computed tomography. Twenty-three patients underwent positron emission tomography-computed tomography and flexible laryngoscopy: 61 per cent of patients had true-positive positron emission tomography-computed tomography scans and 39 per cent had false-positive scan results. Most patients referred to ENT for abnormal findings on positron emission tomography-computed tomography scans had true-positive findings. Asymmetrical fluorine-18 fluorodeoxy-D-glucose uptake should raise suspicion of vocal fold pathology, accepting a false-positive rate of approximately 40 per cent.

  1. Novel image reconstruction algorithm for multi-phase flow tomography system using γ ray method

    International Nuclear Information System (INIS)

    Hao Kuihong; Wang Huaxiang; Gao Mei

    2007-01-01

    After analyzing the reason of image reconstructed algorithm by using the conventional back projection (IBP) is prone to produce spurious line, and considering the characteristic of multi-phase flow tomography, a novel image reconstruction algorithm is proposed, which carries out the intersection calculation using back projection data. This algorithm can obtain a perfect system point spread function, and can eliminate spurious line better. Simulating results show that the algorithm is effective for identifying multi-phase flow pattern. (authors)

  2. Optimizing experimental parameters for the projection requirement in HAADF-STEM tomography

    International Nuclear Information System (INIS)

    Aveyard, R.; Zhong, Z.; Batenburg, K.J.; Rieger, B.

    2017-01-01

    Highlights: • The extent to which HAADF-STEM meets the projection requirement has been studied. • Multislice simulations used to model beam propagation and study signal linearity. • Propagation in crystalline and amorphous materials considered. • Optimal experimental set-up for the projection requirement is discussed. - Abstract: Tomographic reconstruction algorithms offer a means by which a tilt-series of transmission images can be combined to yield a three dimensional model of the specimen. Conventional reconstruction algorithms assume that the measured signal is a linear projection of some property, typically the density, of the material. Here we report the use of multislice simulations to investigate the extent to which this assumption is met in HAADF-STEM imaging. The use of simulations allows for a systematic survey of a range of materials and microscope parameters to inform optimal experimental design. Using this approach it is demonstrated that the imaging of amorphous materials is in good agreement with the projection assumption in most cases. Images of crystalline specimens taken along zone-axes are found to be poorly suited for conventional linear reconstruction algorithms due to channelling effects which produce enhanced intensities compared with off-axis images, and poor compliance with the projection requirement. Off-axis images are found to be suitable for reconstruction, though they do not strictly meet the linearity requirement in most cases. It is demonstrated that microscope parameters can be selected to yield improved compliance with the projection requirement.

  3. Optimizing experimental parameters for the projection requirement in HAADF-STEM tomography

    Energy Technology Data Exchange (ETDEWEB)

    Aveyard, R., E-mail: r.a.aveyard@tudelft.nl [Department of Imaging Physics, Delft University of Technology, 2628CJ Delft (Netherlands); Zhong, Z.; Batenburg, K.J. [Centrum Wiskunde and Informatica, Science Park 123, NL-1098 XG Amsterdam (Netherlands); Rieger, B., E-mail: b.rieger@tudelft.nl [Department of Imaging Physics, Delft University of Technology, 2628CJ Delft (Netherlands)

    2017-06-15

    Highlights: • The extent to which HAADF-STEM meets the projection requirement has been studied. • Multislice simulations used to model beam propagation and study signal linearity. • Propagation in crystalline and amorphous materials considered. • Optimal experimental set-up for the projection requirement is discussed. - Abstract: Tomographic reconstruction algorithms offer a means by which a tilt-series of transmission images can be combined to yield a three dimensional model of the specimen. Conventional reconstruction algorithms assume that the measured signal is a linear projection of some property, typically the density, of the material. Here we report the use of multislice simulations to investigate the extent to which this assumption is met in HAADF-STEM imaging. The use of simulations allows for a systematic survey of a range of materials and microscope parameters to inform optimal experimental design. Using this approach it is demonstrated that the imaging of amorphous materials is in good agreement with the projection assumption in most cases. Images of crystalline specimens taken along zone-axes are found to be poorly suited for conventional linear reconstruction algorithms due to channelling effects which produce enhanced intensities compared with off-axis images, and poor compliance with the projection requirement. Off-axis images are found to be suitable for reconstruction, though they do not strictly meet the linearity requirement in most cases. It is demonstrated that microscope parameters can be selected to yield improved compliance with the projection requirement.

  4. BPF-type region-of-interest reconstruction for parallel translational computed tomography.

    Science.gov (United States)

    Wu, Weiwen; Yu, Hengyong; Wang, Shaoyu; Liu, Fenglin

    2017-01-01

    The objective of this study is to present and test a new ultra-low-cost linear scan based tomography architecture. Similar to linear tomosynthesis, the source and detector are translated in opposite directions and the data acquisition system targets on a region-of-interest (ROI) to acquire data for image reconstruction. This kind of tomographic architecture was named parallel translational computed tomography (PTCT). In previous studies, filtered backprojection (FBP)-type algorithms were developed to reconstruct images from PTCT. However, the reconstructed ROI images from truncated projections have severe truncation artefact. In order to overcome this limitation, we in this study proposed two backprojection filtering (BPF)-type algorithms named MP-BPF and MZ-BPF to reconstruct ROI images from truncated PTCT data. A weight function is constructed to deal with data redundancy for multi-linear translations modes. Extensive numerical simulations are performed to evaluate the proposed MP-BPF and MZ-BPF algorithms for PTCT in fan-beam geometry. Qualitative and quantitative results demonstrate that the proposed BPF-type algorithms cannot only more accurately reconstruct ROI images from truncated projections but also generate high-quality images for the entire image support in some circumstances.

  5. The Impact of Computed Tomography on Decision Making in Tibial Plateau Fractures.

    Science.gov (United States)

    Castiglia, Marcello Teixeira; Nogueira-Barbosa, Marcello Henrique; Messias, Andre Marcio Vieira; Salim, Rodrigo; Fogagnolo, Fabricio; Schatzker, Joseph; Kfuri, Mauricio

    2018-02-14

    Schatzker introduced one of the most used classification systems for tibial plateau fractures, based on plain radiographs. Computed tomography brought to attention the importance of coronal plane-oriented fractures. The goal of our study was to determine if the addition of computed tomography would affect the decision making of surgeons who usually use the Schatzker classification to assess tibial plateau fractures. Image studies of 70 patients who sustained tibial plateau fractures were uploaded to a dedicated homepage. Every patient was linked to a folder which contained two radiographic projections (anteroposterior and lateral), three interactive videos of computed tomography (axial, sagittal, and coronal), and eight pictures depicting tridimensional reconstructions of the tibial plateau. Ten attending orthopaedic surgeons, who were blinded to the cases, were granted access to the homepage and assessed each set of images in two different rounds, separated to each other by an interval of 2 weeks. Each case was evaluated in three steps, where surgeons had access, respectively to radiographs, two-dimensional videos of computed tomography, and three-dimensional reconstruction images. After every step, surgeons were asked to present how would they classify the case using the Schatzker system and which surgical approaches would be appropriate. We evaluated the inter- and intraobserver reliability of the Schatzker classification using the Kappa concordance coefficient, as well as the impact of computed tomography in the decision making regarding the surgical approach for each case, by using the chi-square test and likelihood ratio. The interobserver concordance kappa coefficients after each assessment step were, respectively, 0.58, 0.62, and 0.64. For the intraobserver analysis, the coefficients were, respectively, 0.76, 0.75, and 0.78. Computed tomography changed the surgical approach selection for the types II, V, and VI of Schatzker ( p  < 0.01). The addition of

  6. Comparison of primary tumour volumes delineated on four-dimensional computed tomography maximum intensity projection and 18F-fluorodeoxyglucose positron emission tomography computed tomography images of non-small cell lung cancer

    International Nuclear Information System (INIS)

    Duan, Yili; Li, Jianbin; Zhang, Yingjie; Wang, Wei; Fan, Tingyong; Shao, Qian; Xu, Min; Guo, Yanluan; Sun, Xiaorong; Shang, Dongping

    2015-01-01

    The study aims to compare the positional and volumetric differences of tumour volumes based on the maximum intensity projection (MIP) of four-dimensional CT (4DCT) and 18 F-fluorodexyglucose ( 18 F-FDG) positron emission tomography CT (PET/CT) images for the primary tumour of non-small cell lung cancer (NSCLC). Ten patients with NSCLC underwent 4DCT and 18 F-FDG PET/CT scans of the thorax on the same day. Internal gross target volumes (IGTVs) of the primary tumours were contoured on the MIP images of 4DCT to generate IGTV MIP . Gross target volumes (GTVs) based on PET (GTV PET ) were determined with nine different threshold methods using the auto-contouring function. The differences in the volume, position, matching index (MI) and degree of inclusion (DI) of the GTV PET and IGTV MIP were investigated. In volume terms, GTV PET2.0 and GTV PET20% approximated closely to IGTV MIP with mean volume ratio of 0.93 ± 0.45 and 1.06 ± 0.43, respectively. The best MI was between IGTV MIP and GTV PET20% (0.45 ± 0.23). The best DI of IGTV MIP in GTV PET was IGTV MIP in GTV PET20% (0.61 ± 0.26). In 3D PET images, the GTVPET contoured by standardised uptake value (SUV) 2.0 or 20% of maximal SUV (SUV max ) approximate closely to the IGTV MIP in target size, while the spatial mismatch is apparent between them. Therefore, neither of them could replace IGTV MIP in spatial position and form. The advent of 4D PET/CT may improve the accuracy of contouring the perimeter for moving targets.

  7. A new recontruction algorithm for use with capacitance-based tomography

    Directory of Open Access Journals (Sweden)

    Ø. Isaksen

    1994-01-01

    Full Text Available A new reconstruction algorithm for use with capacitance-based process tomography is proposed. A numerical simulator, capable of calculating the capacitances for a particular sensor configuration and flow regime is used together with a parameter representation of the dielectric distribution and an optimization algorithm. The algorithm calculates these parameters and hence the dielectric distribution, by minimizing a function defined as a weighted sum of square differences between the measured and estimated capacitances. The method is tested by using both synthetic and experimental data, and the results are compared with results from the commonly used Linear Back Projection (LBP algorithm. The method is capable of obtaining the correct parameter values for all the flow regimes tested, and does provide a better estimate than the LBP method. The method proves to be very promising, and is a step towards quantitative capacitance tomography.

  8. Estimation of Material Distribution at the Premixing Stage in the Steam Explosion Event using the Electric Tomography

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Jae Young; Seo, S. W.; Lee, C. H. [Handong Global Univ., Pohang (Korea, Republic of)

    2008-02-15

    Axixal tomography code which is developed in 2005-06, is improved through the present research. In the first year, the objects of project are the measurement of water level and measurement of bubble distribution that are significant measurement factor used in axial tomography. To improve the previous axial tomography code, we gave attention to inverse algorithm. Inverse algorithm is the method to solve a system of equations that has many unknowns than the number of equations. The system of equations is not solved exactly. To find a more exact approximated solution of the system of equations, it is proposed to the number of equations increasing. If the number of electrode is increased, image reconstruction results are better than the previous one, because of the number of equations corresponded to the number of independent measurement. Therefore, the axial tomography code was changed by increase in the number of electrode. And phase distribution was reconstructed by new axial tomography code. As the results, image reconstruction performance is improved. The water level and bubble distribution is measured more precisely than the previous study.

  9. Creation of a Geant4 Muon Tomography Package for Imaging of Nuclear Fuel in Dry Cask Storage

    Energy Technology Data Exchange (ETDEWEB)

    Tsoukalas, Lefteri H. [Purdue Univ., West Lafayette, IN (United States)

    2016-03-01

    This is the final report of the NEUP project “Creation of a Geant4 Muon Tomography Package for Imaging of Nuclear Fuel in Dry Cask Storage”, DE-NE0000695. The project started on December 1, 2013 and this report covers the period December 1, 2013 through November 30, 2015. The project was successfully completed and this report provides an overview of the main achievements, results and findings throughout the duration of the project. Additional details can be found in the main body of this report and on the individual Quarterly Reports and associated Deliverables of the project, uploaded in PICS-NE.

  10. Children's (Pediatric) CT (Computed Tomography)

    Medline Plus

    Full Text Available ... News Physician Resources Professions Site Index A-Z Children's (Pediatric) CT (Computed Tomography) Pediatric computed tomography (CT) ... are the limitations of Children's CT? What is Children's CT? Computed tomography, more commonly known as a ...

  11. EDITORIAL: Optical tomography and digital holography

    Science.gov (United States)

    Coupland, Jeremy; Lobera, Julia

    2008-07-01

    this for the case of mono-disperse particles in air. Here the number density of the particles is such that multiple scattering is prevalent; however, a priori knowledge of particle size and refractive index allows individual particles to be located accurately. In general, reconstruction can be thought of as a nonlinear optimization process that is used to discover the object which best explains the measured field and is consistent with a priori information. As Gire et al point out in their article, a priori knowledge can also be used to overcome the Nyquist sampling criteria. Although some caution should be exercised (for example, it is not usually possible to decide whether a given solution is unique), it is interesting to note that despite the disparity in resolution, digital holography and computer technology might yet create 3D images of greater clarity than the best optical holograms. References [1] Schnars U and Jueptner W 2005 Digital Holography (Berlin: Springer) ISBN: 978 3 540 21934 7 [2] Gabor D 1948 A new microscopic principle Nature 161 777-8 [3] Bjelkhagen H I 1993 Silver-Halide Recording Materials (Berlin: Springer) ISBN 3 540 58619 9 [4] Leendertz J A 1970 Interferometric displacement measurement on scattering surfaces utilizing speckle effect J. Phys. E: Sci. Instrum. 3 214-8 [5] Marquet P, Rappaz B, Magistretti P J, Cuche E, Emery Y, Colomb T and Depeursinge C 2005 Digital holographic microscopy: a noninvasive contrast imaging technique allowing quantitative visualization of living cells with subwavelength axial accuracy Opt. Lett. 30 468-70 [6] Wolf E 1969 Three-dimensional structure determination of semi-transparent objects from holographic data Opt. Commun. 1 153-6 [7] Dandliker R and Weiss K 1970 Reconstruction of the three-dimensional refractive index from scattered waves Opt. Commun. 1 323-8 [8] Coupland J and Lobera J 2007 International Workshop on Digital Holographic Reconstruction and Optical Tomography for Engineering Applications ISBN 978 0

  12. A novel forward projection-based metal artifact reduction method for flat-detector computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Prell, Daniel; Kyriakou, Yiannis; Beister, Marcel; Kalender, Willi A [Institute of Medical Physics, University of Erlangen-Nuernberg, Henkestrasse 91, 91052 Erlangen (Germany)], E-mail: daniel.prell@imp.uni-erlangen.de

    2009-11-07

    Metallic implants generate streak-like artifacts in flat-detector computed tomography (FD-CT) reconstructed volumetric images. This study presents a novel method for reducing these disturbing artifacts by inserting discarded information into the original rawdata using a three-step correction procedure and working directly with each detector element. Computation times are minimized by completely implementing the correction process on graphics processing units (GPUs). First, the original volume is corrected using a three-dimensional interpolation scheme in the rawdata domain, followed by a second reconstruction. This metal artifact-reduced volume is then segmented into three materials, i.e. air, soft-tissue and bone, using a threshold-based algorithm. Subsequently, a forward projection of the obtained tissue-class model substitutes the missing or corrupted attenuation values directly for each flat detector element that contains attenuation values corresponding to metal parts, followed by a final reconstruction. Experiments using tissue-equivalent phantoms showed a significant reduction of metal artifacts (deviations of CT values after correction compared to measurements without metallic inserts reduced typically to below 20 HU, differences in image noise to below 5 HU) caused by the implants and no significant resolution losses even in areas close to the inserts. To cover a variety of different cases, cadaver measurements and clinical images in the knee, head and spine region were used to investigate the effectiveness and applicability of our method. A comparison to a three-dimensional interpolation correction showed that the new approach outperformed interpolation schemes. Correction times are minimized, and initial and corrected images are made available at almost the same time (12.7 s for the initial reconstruction, 46.2 s for the final corrected image compared to 114.1 s and 355.1 s on central processing units (CPUs))

  13. A novel forward projection-based metal artifact reduction method for flat-detector computed tomography

    International Nuclear Information System (INIS)

    Prell, Daniel; Kyriakou, Yiannis; Beister, Marcel; Kalender, Willi A

    2009-01-01

    Metallic implants generate streak-like artifacts in flat-detector computed tomography (FD-CT) reconstructed volumetric images. This study presents a novel method for reducing these disturbing artifacts by inserting discarded information into the original rawdata using a three-step correction procedure and working directly with each detector element. Computation times are minimized by completely implementing the correction process on graphics processing units (GPUs). First, the original volume is corrected using a three-dimensional interpolation scheme in the rawdata domain, followed by a second reconstruction. This metal artifact-reduced volume is then segmented into three materials, i.e. air, soft-tissue and bone, using a threshold-based algorithm. Subsequently, a forward projection of the obtained tissue-class model substitutes the missing or corrupted attenuation values directly for each flat detector element that contains attenuation values corresponding to metal parts, followed by a final reconstruction. Experiments using tissue-equivalent phantoms showed a significant reduction of metal artifacts (deviations of CT values after correction compared to measurements without metallic inserts reduced typically to below 20 HU, differences in image noise to below 5 HU) caused by the implants and no significant resolution losses even in areas close to the inserts. To cover a variety of different cases, cadaver measurements and clinical images in the knee, head and spine region were used to investigate the effectiveness and applicability of our method. A comparison to a three-dimensional interpolation correction showed that the new approach outperformed interpolation schemes. Correction times are minimized, and initial and corrected images are made available at almost the same time (12.7 s for the initial reconstruction, 46.2 s for the final corrected image compared to 114.1 s and 355.1 s on central processing units (CPUs)).

  14. Mesenteric panniculitis: computed tomography aspects

    International Nuclear Information System (INIS)

    Moreira, Luiza Beatriz Melo; Alves, Jose Ricardo Duarte; Marchiori, Edson; Pinheiro, Ricardo Andrade; Melo, Alessandro Severo Alves de; Noro, Fabio

    2001-01-01

    Mesenteric panniculitis is an inflammatory process that represents the second stage of a rare progressive disease involving the adipose tissue of the mesentery. Imaging methods used in the diagnosis of mesenteric panniculitis include barium studies, ultrasonography, computed tomography and magnetic resonance imaging. Computed tomography is important for both, diagnosis and evaluation of the extension of the disease and treatment monitoring. Computed tomography findings may vary according to the stage of the disease and the amount of inflammatory material or fibrosis. There is also good correlation between the computed tomography and anatomical pathology findings. The authors studied 10 patients with mesenteric panniculitis submitted to computed tomography. Magnetic resonance imaging was also performed in one patient. In all patients, computed tomography revealed a heterogeneous mass in the mesentery with density of fat, interspersed with areas of soft tissue density and dilated vessels. (author)

  15. Evaluation of Biomaterials Using Micro-Computerized Tomography

    International Nuclear Information System (INIS)

    Torris, A. T. Arun; Columbus, K. C. Soumya; Saaj, U. S.; Krishnan, Kalliyana V.; Nair, Manitha B.

    2008-01-01

    Micro-computed tomography or Micro-CT is a high resolution, non-invasive, x-ray scanning technique that allows precise three-dimensional imaging and quantification of micro-architectural and structural parameters of objects. Tomographic reconstruction is based on a cone-beam convolution-back-projection algorithm. Micro-architectural and structural parameters such as porosity, surface area to volume ratio, interconnectivity, pore size, wall thickness, anisotropy and cross-section area of biomaterials and bio-specimens such as trabecular bone, polymer scaffold, bio-ceramics and dental restorative were evaluated through imaging and computer aided manipulation of the object scan data sets.

  16. Iterative methods for tomography problems: implementation to a cross-well tomography problem

    Science.gov (United States)

    Karadeniz, M. F.; Weber, G. W.

    2018-01-01

    The velocity distribution between two boreholes is reconstructed by cross-well tomography, which is commonly used in geology. In this paper, iterative methods, Kaczmarz’s algorithm, algebraic reconstruction technique (ART), and simultaneous iterative reconstruction technique (SIRT), are implemented to a specific cross-well tomography problem. Convergence to the solution of these methods and their CPU time for the cross-well tomography problem are compared. Furthermore, these three methods for this problem are compared for different tolerance values.

  17. Comparison of tomography reconstruction by maximum entropy and filtered retro projection

    International Nuclear Information System (INIS)

    Abdala, F.J.P.; Simpson, D.M.; Roberty, N.C.

    1992-01-01

    The tomographic reconstruction with few projections is studied, comparing the maximum entropy method with filtered retro projection. Simulations with and without the presence of noise and also with the presence of an object of high density inside of the skull are showed. (C.G.C.)

  18. Fluorodeoxyglucose-positron emission tomography/computed tomography imaging features of colloid adenocarcinoma of the lung: a case report.

    Science.gov (United States)

    Wang, ZhenGuang; Yu, MingMing; Chen, YueHua; Kong, Yan

    2017-07-27

    Colloid adenocarcinoma of the lung is a rare subtype of variants of invasive adenocarcinomas. We report the appearance of this unusual entity on 18 F-fluorodeoxyglucose positron emission tomography/computed tomography. A 60-year-old man of Chinese Han nationality coughed with a little white sputum for 1 month. Chest computed tomography showed multiple bilateral subpleural nodules and plaques accompanied by air bronchograms, which were most concentrated in the lower lobe of his right lung. Positron emission tomography indicated increased radioactivity uptake with a maximum standardized uptake value of 3.5. Positron emission tomography/computed tomography showed a soft tissue density lesion in his left adrenal gland with a maximum standardized uptake value of 4.1. The positron emission tomography/computed tomography appearance suggested a primary colloid adenocarcinoma in the lower lobe of his right lung accompanied by intrapulmonary and left adrenal gland metastases. The diagnostic rate of colloid adenocarcinoma can be increased by combining the anatomic and metabolic information of lesions. The advantage of positron emission tomography/computed tomography in the diagnosis of colloid adenocarcinoma, as with other cancers, is the ability to locate extrapulmonary disease, facilitating clinical staging.

  19. Development of three-dimensional computed tomography system using TNRF2 of JRR-3M

    Energy Technology Data Exchange (ETDEWEB)

    Murata, Yutaka; Mochiki, Koh-ichi [Musashi Inst. of Tech., Tokyo (Japan); Matsubayashi, Masahito

    1998-01-01

    A three-dimensional filtering engine, a convolution engine, and a back projection engine were developed for real-time signal processing of three-dimensional computed tomography. The performance of the system was measured and through-put of 0.5 second per one cross sectional data processing was attained. (author)

  20. Children's (Pediatric) CT (Computed Tomography)

    Medline Plus

    Full Text Available ... Site Index A-Z Children's (Pediatric) CT (Computed Tomography) Pediatric computed tomography (CT) is a fast, painless exam that uses ... of Children's CT? What is Children's CT? Computed tomography, more commonly known as a CT or CAT ...

  1. Children's (Pediatric) CT (Computed Tomography)

    Medline Plus

    Full Text Available ... Z Children's (Pediatric) CT (Computed Tomography) Pediatric computed tomography (CT) is a fast, painless exam that uses special ... the limitations of Children's CT? What is Children's CT? Computed tomography, more commonly known as a CT or CAT ...

  2. Multislice computed tomography coronary angiography

    NARCIS (Netherlands)

    F. Cademartiri (Filippo)

    2005-01-01

    markdownabstract__Abstract__ Computed Tomography (CT) imaging is also known as "CAT scanning" (Computed Axial Tomography). Tomography is from the Greek word "tomos" meaning "slice" or "section" and "graphia" meaning "describing". CT was invented in 1972 by British engineer Godfrey Hounsfield

  3. Incidental head and neck findings on 18F-fluoro-deoxy-glucose positron emission tomography computed tomography.

    Science.gov (United States)

    Williams, S P; Kinshuck, A J; Williams, C; Dwivedi, R; Wieshmann, H; Jones, T M

    2015-09-01

    The overlapping risk factors for lung and head and neck cancer present a definite risk of synchronous malignant pathology. This is the first study to specifically review incidental positron emission tomography computed tomography findings in the head and neck region in lung carcinoma patients. A retrospective review was performed of all lung cancer patients who underwent positron emission tomography computed tomography imaging over a five-year period (January 2008 - December 2012), identified from the Liverpool thoracic multidisciplinary team database. Six hundred and nine patients underwent positron emission tomography computed tomography imaging over this period. In 76 (12.5 per cent) scans, incidental regions of avid 18F-fluoro-deoxy-glucose uptake were reported in the head and neck region. In the 28 patients who were fully investigated, there were 4 incidental findings of malignancy. In lung cancer patients undergoing investigative positron emission tomography computed tomography scanning, a significant number will also present with areas of clinically significant 18F-fluoro-deoxy-glucose uptake in the head and neck region. Of these, at least 5 per cent may have an undiagnosed malignancy.

  4. Neutron Tomography at the Los Alamos Neutron Science Center

    International Nuclear Information System (INIS)

    Myers, William Riley

    2017-01-01

    Neutron imaging is an incredibly powerful tool for non-destructive sample characterization and materials science. Neutron tomography is one technique that results in a three-dimensional model of the sample, representing the interaction of the neutrons with the sample. This relies both on reliable data acquisition and on image processing after acquisition. Over the course of the project, the focus has changed from the former to the latter, culminating in a large-scale reconstruction of a meter-long fossilized skull. The full reconstruction is not yet complete, though tools have been developed to improve the speed and accuracy of the reconstruction. This project helps to improve the capabilities of LANSCE and LANL with regards to imaging large or unwieldy objects.

  5. Neutron Tomography at the Los Alamos Neutron Science Center

    Energy Technology Data Exchange (ETDEWEB)

    Myers, William Riley [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2017-08-07

    Neutron imaging is an incredibly powerful tool for non-destructive sample characterization and materials science. Neutron tomography is one technique that results in a three-dimensional model of the sample, representing the interaction of the neutrons with the sample. This relies both on reliable data acquisition and on image processing after acquisition. Over the course of the project, the focus has changed from the former to the latter, culminating in a large-scale reconstruction of a meter-long fossilized skull. The full reconstruction is not yet complete, though tools have been developed to improve the speed and accuracy of the reconstruction. This project helps to improve the capabilities of LANSCE and LANL with regards to imaging large or unwieldy objects.

  6. An introduction to emission computed tomography

    International Nuclear Information System (INIS)

    Williams, E.D.

    1985-01-01

    This report includes salient features of the theory and an examination of practical considerations for someone who is using or introducing tomography, selecting equipment for it or wishing to develop a clinical application. Emphasis is on gamma camera tomography. The subject is dealt with under the following headings: emission computed and gamma camera tomography and the relationship to other medical imaging techniques, the tomographic reconstruction technique theory, rotating gamma camera tomography, attenuation correction and quantitative reconstruction, other single photon tomographic techniques, positron tomography, image display, clinical application of single photon and positron tomography, and commercial systems for SPECT. Substantial bibliography. (U.K.)

  7. Access to the kinematic information for the velocity model determination by 3-D reflexion tomography; Acces a l'information cinematique pour la determination du modele de vitesse par tomographie de reflexion 3D

    Energy Technology Data Exchange (ETDEWEB)

    Broto, K.

    1999-04-01

    The access to a reliable image of the subsurface requires a kinematically correct velocity depth model.Reflection tomography allows to meet this requirement if a complete and coherent pre-stack kinematic database can be provided. However, in case of complex sub-surfaces, wave propagation may lead to hardly interpretable seismic events in the time data. The SMART method is a sequential method that relies on reflection tomography for updating the velocity model and on the pre-stack depth migrated domain for extracting kinematic information that is not readily accessible in the time domain. For determining 3-D subsurface velocity models in case of complex structures, we propose the seriated SMART 2-D method as an alternative to the currently inconceivable SMART 3-D method. In order to extract kinematic information from a 3-D pre-stack data set, we combine detours through the 2-D pre-stack depth domain for a number of selected lines of the studied 3-D survey and 3-D reflection tomography for updating the velocity model. The travel-times from the SMART method being independent of the velocity model used for passing through the pre-stack depth migrated domain, the access to 3-D travel-times is ensured, even if they have been obtained via a 2-D domain. Besides, we propose to build a kinematical guide for ensuring the coherency of the seriated 2-D pre-stack depth interpretations and the access to a complete 3-D pre-stack kinematic database when dealing with structures associated with 3-D wave propagation. We opt for a blocky representation of the velocity model in order to be able to cope with complex structures. This representation leads us to define specific methodological rules for carrying out the different steps of the seriated SMART 2-D method. We also define strategies, built from the analysis of first inversion results, for an efficient application of reflection tomography. Besides, we discuss the problem of uncertainties to be assigned to travel-times obtained

  8. Spectroscopic micro-tomography of metallic-organic composites by means of photon-counting detectors

    Czech Academy of Sciences Publication Activity Database

    Pichotka, Martin; Jakůbek, Jan; Vavřík, Daniel

    2015-01-01

    Roč. 10, č. 12 (2015), C12033 ISSN 1748-0221 R&D Projects: GA MŠk(CZ) LO1219 Keywords : micro-tomography * photon-counting detectors * metallic-organic composites Subject RIV: BH - Optics, Masers, Lasers Impact factor: 1.310, year: 2015 http://iopscience.iop.org/article/10.1088/1748-0221/10/12/C12033/pdf

  9. Computer tomography in otolaryngology

    International Nuclear Information System (INIS)

    Gradzki, J.

    1981-01-01

    The principles of design and the action of computer tomography which was applied also for the diagnosis of nose, ear and throat diseases are discussed. Computer tomography makes possible visualization of the structures of the nose, nasal sinuses and facial skeleton in transverse and eoronal planes. The method enables an accurate evaluation of the position and size of neoplasms in these regions and differentiation of inflammatory exudates against malignant masses. In otology computer tomography is used particularly in the diagnosis of pontocerebellar angle tumours and otogenic brain abscesses. Computer tomography of the larynx and pharynx provides new diagnostic data owing to the possibility of obtaining transverse sections and visualization of cartilage. Computer tomograms of some cases are presented. (author)

  10. Cardiac positron emission tomography

    International Nuclear Information System (INIS)

    Eftekhari, M.; Ejmalian, G.

    2003-01-01

    Positron emission tomography is an intrinsically tool that provide a unique and unparalleled approach for clinicians and researchers to interrogate the heart noninvasively. The ability to label substances of physiological interest with positron-emitting radioisotopes has permitted insight into normal blood flow and metabolism and the alterations that occur with disease states. Positron emission tomography of the heart has evolved as a unique, noninvasive approach for the assessment of myocardial perfusion, metabolism, and function. Because of the intrinsic quantitative nature of positron emission tomography measurements as well as the diverse compounds that can be labeled with positron- emitting radioisotopes, studies with positron emission tomography have provided rich insight into the physiology of the heart under diverse conditions

  11. Sparse image representation for jet neutron and gamma tomography

    Energy Technology Data Exchange (ETDEWEB)

    Craciunescu, T. [EURATOM-MEdC Association, Institute for Laser, Plasma and Radiation Physics, Bucharest (Romania); Kiptily, V. [EURATOM/CCFE Association, Culham Science Centre, Abingdon (United Kingdom); Murari, A. [Consorzio RFX, Associazione EURATOM-ENEA per la Fusione, Padova (Italy); Tiseanu, I.; Zoita, V. [EURATOM-MEdC Association, Institute for Laser, Plasma and Radiation Physics, Bucharest (Romania)

    2013-10-15

    Highlights: •A new tomographic method for the reconstruction of the 2-D neutron and gamma emissivity on JET. •The method is based on the sparse representation of the reconstructed image in an over-complete dictionary. •Several techniques, based on a priori information are used to regularize this highly limited data set tomographic problem. •The proposed method provides good reconstructions in terms of shapes and resolution. -- Abstract: The JET gamma/neutron profile monitor plasma coverage of the emissive region enables tomographic reconstruction. However, due to the availability of only two projection angles and to the coarse sampling, tomography is a highly limited data set problem. A new reconstruction method, based on the sparse representation of the reconstructed image in an over-complete dictionary, has been developed and applied to JET neutron/gamma tomography. The method has been tested on JET experimental data and significant results are presented. The proposed method provides good reconstructions in terms of shapes and resolution.

  12. Archaeology benefits from neutron tomography investigations in South Africa

    Energy Technology Data Exchange (ETDEWEB)

    Beer, F.C. de [Radiation Sciences, Research and Development, Necsa (South Africa)], E-mail: Frikkie.DeBeer@necsa.co.za; Botha, H. [South African Institute for Objects Conservation, Twee Riviere, Eastern Cape (South Africa); Ferg, E. [Department of Chemistry, Nelson Mandela Metropolitan University, Port Elizabeth (South Africa); Grundlingh, R. [South African Institute for Objects Conservation, Twee Riviere, Eastern Cape (South Africa); Smith, A. [National Cultural History Museum, Pretoria (South Africa)

    2009-06-21

    This paper describes the neutron tomography investigation on archaeological artifacts from museums in South Africa. While X-rays fail to penetrate the brass matrix of the samples, neutrons can easily reveal, on a non-invasive manner, the content and structure of these precious samples. The South African Neutron Radiography (SANRAD) facility, located at the SAFARI-1 nuclear research reactor, operated by Necsa near Pretoria, South Africa, was utilized in a tomography mode during the investigations. For the 3D tomographical reconstruction of the sample, 375 projections were collected while the sample was rotated around a defined axis through 360 deg. rotation interval. The results show that the technique is able to reconstruct structural features very well and in particular, highly absorbing zones and the presence of defects in the bulk. The samples originate from collections at museums in South Africa and these investigations were the first of its kind performed in the country.

  13. Archaeology benefits from neutron tomography investigations in South Africa

    International Nuclear Information System (INIS)

    Beer, F.C. de; Botha, H.; Ferg, E.; Grundlingh, R.; Smith, A.

    2009-01-01

    This paper describes the neutron tomography investigation on archaeological artifacts from museums in South Africa. While X-rays fail to penetrate the brass matrix of the samples, neutrons can easily reveal, on a non-invasive manner, the content and structure of these precious samples. The South African Neutron Radiography (SANRAD) facility, located at the SAFARI-1 nuclear research reactor, operated by Necsa near Pretoria, South Africa, was utilized in a tomography mode during the investigations. For the 3D tomographical reconstruction of the sample, 375 projections were collected while the sample was rotated around a defined axis through 360 deg. rotation interval. The results show that the technique is able to reconstruct structural features very well and in particular, highly absorbing zones and the presence of defects in the bulk. The samples originate from collections at museums in South Africa and these investigations were the first of its kind performed in the country.

  14. Generalized Filtered Back-Projection for Digital Breast Tomosynthesis Reconstruction

    NARCIS (Netherlands)

    Erhard, K.; Grass, M.; Hitziger, S.; Iske, A.; Nielsen, T.

    2012-01-01

    Filtered back-projection (FBP) has been commonly used as an efficient and robust reconstruction technique in tomographic X-ray imagingduring the last decades. For limited angle tomography acquisitions such as digital breast tomosynthesis, however, standard FBP reconstruction algorithms provide poor

  15. Analysis of the percentage voids of test and field specimens using computerized tomography

    International Nuclear Information System (INIS)

    Braz, D.; Lopes, R.T.; Motta, L.M.G. da

    1999-01-01

    Computerized tomography has been an excellent tool of analysis of asphaltics mixtures, because it allows comparison of the quality and integrity of test and field specimens. It was required to detect and follow the evolution of cracks, when these mixtures were submitted to fatigue tests, and also helping to interpret the distribution of tensions and deformations which occur in the several types of solicitations imposed to the mixtures. Comparing the medium values of percentage voids obtained from tomographic images with the project's values, it can be observed that the values of test and field specimens for the wearing course are closer to the ones of the project than the ones of the binder. It can be verified that the wearing course specimens always present a distribution of the aggregate, and voids quite homogeneously in the whole profile of the sample, while the binder specimens show an accentuated differentiation of the same factors in the several heights of the sample. Therefore, when choosing a slice for tomography, these considerations should be taken into account

  16. The new opt-out Dutch National Breast Implant Registry - Lessons learnt from the road to implementation.

    Science.gov (United States)

    Rakhorst, Hinne A; Mureau, Marc A M; Cooter, Rodney D; McNeil, John; van Hooff, Miranda; van der Hulst, René; Hommes, Juliette; Hoornweg, Marije; Moojen-Zaal, Laura; Liem, Patricia; Mathijssen, Irene M J

    2017-10-01

    An estimated 1-3% of all women in the Netherlands carry breast implants. Since the introduction five decades ago, problems with a variety of breast implants have emerged with direct consequences for the patients' health. Plastic surgeons worldwide reacted through campaigning for auditing on long-term implant quality, surgeon performance, and institutional outcomes in implant registries. Especially, the PIP implant scandal of 2010 demonstrated the paucity of epidemiological data and uncovered a weakness in our ability to even 'track and trace' patients. In addition, a recent report of the Dutch Institute of National Health showed a lack of compliance of 100% of breast implant producers to CE requirements. These arguments stress the need for an independent implant registry. Insufficient capture rates or dependence from the implant producers made the variety of national and international patient registries unreliable. The Dutch Breast Implant Registry (DBIR) is unique because it is an opt-out registry without the need for informed consent and thus a high capture rate. Furthermore, an estimated 95% of breast implants are implanted by board-certified plastic surgeons. Funding was received from a non-governmental organisation to increase the quality of health care in the Netherlands, and maintenance is gathered by 25 euros per implant inserted. This article describes the way the Dutch have set up their system, with special attention to the well-known hurdles of starting a patient registry. Examples include: funding, medical ethical issues, opt out system, benchmarking, quality assurance as well as governance and collaboration. The Dutch consider their experience and data shareware for others to be used globally to the benefit of patient safety and quality improvement. Copyright © 2017 British Association of Plastic, Reconstructive and Aesthetic Surgeons. Published by Elsevier Ltd. All rights reserved.

  17. The neutron computer tomography

    International Nuclear Information System (INIS)

    Matsumoto, G.; Krata, S.

    1983-01-01

    The method of computer tomography (CT) was applied for neutrons instead of X-rays. The neutron radiography image of samples was scanned by microphotometer to get the transmission data. This process was so time-consuming that the number of incident angles to samples could not be increased. The transmission data was processed by FACOM computer and CT image was gained. In the experiment at the Japan Research Reactor No. 4 at Tokai-mura with 18 projection angles, the resolution of paraffin in the aluminum block was less than 0.8 mm. In the experiment at Van de Graaf accelerator of Nagoya University, this same resolution was 1.2 mm because of the angle distribution of neutron beam. This experiment is the preliminary one, the facility which utilizes neutron television and video-recorder will be necessary for the next stage. (Auth.)

  18. Eigenvector decomposition of full-spectrum x-ray computed tomography.

    Science.gov (United States)

    Gonzales, Brian J; Lalush, David S

    2012-03-07

    Energy-discriminated x-ray computed tomography (CT) data were projected onto a set of basis functions to suppress the noise in filtered back-projection (FBP) reconstructions. The x-ray CT data were acquired using a novel x-ray system which incorporated a single-pixel photon-counting x-ray detector to measure the x-ray spectrum for each projection ray. A matrix of the spectral response of different materials was decomposed using eigenvalue decomposition to form the basis functions. Projection of FBP onto basis functions created a de facto image segmentation of multiple contrast agents. Final reconstructions showed significant noise suppression while preserving important energy-axis data. The noise suppression was demonstrated by a marked improvement in the signal-to-noise ratio (SNR) along the energy axis for multiple regions of interest in the reconstructed images. Basis functions used on a more coarsely sampled energy axis still showed an improved SNR. We conclude that the noise-resolution trade off along the energy axis was significantly improved using the eigenvalue decomposition basis functions.

  19. Interior tomography in microscopic CT with image reconstruction constrained by full field of view scan at low spatial resolution

    Science.gov (United States)

    Luo, Shouhua; Shen, Tao; Sun, Yi; Li, Jing; Li, Guang; Tang, Xiangyang

    2018-04-01

    In high resolution (microscopic) CT applications, the scan field of view should cover the entire specimen or sample to allow complete data acquisition and image reconstruction. However, truncation may occur in projection data and results in artifacts in reconstructed images. In this study, we propose a low resolution image constrained reconstruction algorithm (LRICR) for interior tomography in microscopic CT at high resolution. In general, the multi-resolution acquisition based methods can be employed to solve the data truncation problem if the project data acquired at low resolution are utilized to fill up the truncated projection data acquired at high resolution. However, most existing methods place quite strict restrictions on the data acquisition geometry, which greatly limits their utility in practice. In the proposed LRICR algorithm, full and partial data acquisition (scan) at low and high resolutions, respectively, are carried out. Using the image reconstructed from sparse projection data acquired at low resolution as the prior, a microscopic image at high resolution is reconstructed from the truncated projection data acquired at high resolution. Two synthesized digital phantoms, a raw bamboo culm and a specimen of mouse femur, were utilized to evaluate and verify performance of the proposed LRICR algorithm. Compared with the conventional TV minimization based algorithm and the multi-resolution scout-reconstruction algorithm, the proposed LRICR algorithm shows significant improvement in reduction of the artifacts caused by data truncation, providing a practical solution for high quality and reliable interior tomography in microscopic CT applications. The proposed LRICR algorithm outperforms the multi-resolution scout-reconstruction method and the TV minimization based reconstruction for interior tomography in microscopic CT.

  20. Correction for polychromatic aberration in computed tomography images

    International Nuclear Information System (INIS)

    Naparstek, A.

    1979-01-01

    A method and apparatus for correcting a computed tomography image for polychromatic aberration caused by the non-linear interaction (i.e. the energy dependent attenuation characteristics) of different body constituents, such as bone and soft tissue, with a polychromatic X-ray beam are described in detail. An initial image is conventionally computed from path measurements made as source and detector assembly scan a body section. In the improvement, each image element of the initial computed image representing attenuation is recorded in a store and is compared with two thresholds, one representing bone and the other soft tissue. Depending on the element value relative to the thresholds, a proportion of the respective constituent is allocated to that element location and corresponding bone and soft tissue projections are determined and stored. An error projection generator calculates projections of polychromatic aberration errors in the raw image data from recalled bone and tissue projections using a multidimensional polynomial function which approximates the non-linear interaction involved. After filtering, these are supplied to an image reconstruction computer to compute image element correction values which are subtracted from raw image element values to provide a corrected reconstructed image for display. (author)

  1. Positron emission tomography with Positome, 2

    International Nuclear Information System (INIS)

    Nukui, Hideaki; Yamamoto, Y.L.; Thompson, C.J.; Feindel, W.

    1979-01-01

    Positron emission tomography with Positome II using 68 Ga-EDTA was performed in cases with brain tumor and cerebral arteriovenous malformation. A significant focal uptake in static study and hemodynamic changes in dynamic study were noted in all cases except one case with intracranial lipoma. Comparing this method with sup(99m) Tc-pertechnetate cerebral image study and computerized axial tomography, the diagnostic rate for detecting brain tumor was almost equal in all of these three methods. However, detecting and localizing was easier and clearer in static positron emission tomography with 68 Ga-EDTA than in sup(99m) Tc-pertechnetate cerebral image and computerized axial tomography without infusion of contrast medium. Furthermore, static positron emission tomography with 68 Ga-EDTA was superior to computerized axial tomography without infusion of contrast medium for detecting cerebral arteriovenous malformation. Concerning dynamic positron emission tomography with 68 Ga-EDTA, semiquantitative values obtained by this method correlated well with findings of computerized axial tomography and was thought to be more precise and in detail than the findings of sup(99m) Tc-pertechnetate cerebral image study. Summation of the previous studies about dynamic positron emission tomography with 77 Kr in occlusive cerebrovascular disease is also reported. In conclusion, static positron emission tomography with 68 Ga-EDTA is a very useful diagnostic method for detecting and localizing brain tumor and cerebral arteriovenous malformation without any attendant complications. Furthermore, a good combination of static and dynamic positron emission tomography and computerized axial tomography appear to be outstandingly effective for not only detecting the lesion but also understanding the pathophysiological aspect in cases with various intracranial lesions. (author)

  2. Computed tomography for radiographers

    International Nuclear Information System (INIS)

    Brooker, M.

    1986-01-01

    Computed tomography is regarded by many as a complicated union of sophisticated x-ray equipment and computer technology. This book overcomes these complexities. The rigid technicalities of the machinery and the clinical aspects of computed tomography are discussed including the preparation of patients, both physically and mentally, for scanning. Furthermore, the author also explains how to set up and run a computed tomography department, including advice on how the room should be designed

  3. Priority choice experimental two-qubit tomography: measuring one by one all elements of density matrices

    Czech Academy of Sciences Publication Activity Database

    Bartkiewicz, K.; Černoch, Antonín; Lemr, K.; Miranowicz, A.

    2016-01-01

    Roč. 6, Jan (2016), 1-7, č. článku 19610. ISSN 2045-2322 R&D Projects: GA ČR GAP205/12/0382 Institutional support: RVO:68378271 Keywords : entangled photons * state tomography Subject RIV: BH - Optics, Masers, Lasers Impact factor: 4.259, year: 2016

  4. Deep learning for plasma tomography using the bolometer system at JET

    Energy Technology Data Exchange (ETDEWEB)

    Matos, Francisco A. [Instituto Superior Técnico (IST), University of Lisbon (Portugal); Ferreira, Diogo R., E-mail: diogo.ferreira@tecnico.ulisboa.pt [Instituto Superior Técnico (IST), University of Lisbon (Portugal); Carvalho, Pedro J. [Instituto de Plasmas e Fusão Nuclear (IPFN), IST, University of Lisbon (Portugal)

    2017-01-15

    Highlights: • Plasma tomography is able to reconstruct the plasma profile from radiation measurements along several lines of sight. • The reconstruction can be performed with neural networks, but previous work focused on learning a parametric model. • Deep learning can be used to reconstruct the full 2D plasma profile with the same resolution as existing tomograms. • We introduce a deep neural network to generate an image from 1D projection data based on a series of up-convolutions. • After training on JET data, the network provides accurate reconstructions with an average pixel error as low as 2%. - Abstract: Deep learning is having a profound impact in many fields, especially those that involve some form of image processing. Deep neural networks excel in turning an input image into a set of high-level features. On the other hand, tomography deals with the inverse problem of recreating an image from a number of projections. In plasma diagnostics, tomography aims at reconstructing the cross-section of the plasma from radiation measurements. This reconstruction can be computed with neural networks. However, previous attempts have focused on learning a parametric model of the plasma profile. In this work, we use a deep neural network to produce a full, pixel-by-pixel reconstruction of the plasma profile. For this purpose, we use the overview bolometer system at JET, and we introduce an up-convolutional network that has been trained and tested on a large set of sample tomograms. We show that this network is able to reproduce existing reconstructions with a high level of accuracy, as measured by several metrics.

  5. Computed tomography in the diagnosis of fractures of the maxillofacial area

    International Nuclear Information System (INIS)

    Angelova, I.; Yordanov, G.; Sirakov, V.; Velkova, K.

    2013-01-01

    Computed tomography (CT) is the current method of study in maxillofacial region, which produces cross-sectional images of a specific area. There are still questions about methodology and radiation exposure. The aim of the present study is to evaluate the CT in diagnosis of fractures in maxillofacial region. 42 patients with traumatic injuries to the facial skeleton are examined. Fractures of maxilla are occurring in 14.6 % of patients with traumatic diseases. Fractures of maxilla and zygomatic bone are found in 29.3 percent of the traumatic event. Isolated nasal bone fracture is observed in 2.4% of ail fractures. Compound fractures constitute 17.1% of the tested fractures. This group of patients are positioned at second place in frequency. Mandibular fractures ranked first in frequency -36.6% of all traumatic lesions. The methods include: 1. Slice computed tomography in the axial and coronary projection 2. Spiral CT in axial projection and coronary one. 3. Cone Beam Computed Tomography. CT diagnosis is based on an analysis of all the images. It must comply with the data from other studies. When analyzing the results we found that the percentage of patients with primary diagnosis of fractured upper jaw is 11 %, while CT diagnosis of this percentage increases to 16%. The percentage of patients with primary diagnosis fracture of mandibula and CT diagnosis is almost identical. In the present study, 3D and CT have similar results in the detection of fractures. Three-dimensional images dearly show the spatial anatomy of the face, the presence of fragments, as well as monitoring of fracture lines. Key words; Fractures. Maxillofacial Area. CT

  6. Deep learning for plasma tomography using the bolometer system at JET

    International Nuclear Information System (INIS)

    Matos, Francisco A.; Ferreira, Diogo R.; Carvalho, Pedro J.

    2017-01-01

    Highlights: • Plasma tomography is able to reconstruct the plasma profile from radiation measurements along several lines of sight. • The reconstruction can be performed with neural networks, but previous work focused on learning a parametric model. • Deep learning can be used to reconstruct the full 2D plasma profile with the same resolution as existing tomograms. • We introduce a deep neural network to generate an image from 1D projection data based on a series of up-convolutions. • After training on JET data, the network provides accurate reconstructions with an average pixel error as low as 2%. - Abstract: Deep learning is having a profound impact in many fields, especially those that involve some form of image processing. Deep neural networks excel in turning an input image into a set of high-level features. On the other hand, tomography deals with the inverse problem of recreating an image from a number of projections. In plasma diagnostics, tomography aims at reconstructing the cross-section of the plasma from radiation measurements. This reconstruction can be computed with neural networks. However, previous attempts have focused on learning a parametric model of the plasma profile. In this work, we use a deep neural network to produce a full, pixel-by-pixel reconstruction of the plasma profile. For this purpose, we use the overview bolometer system at JET, and we introduce an up-convolutional network that has been trained and tested on a large set of sample tomograms. We show that this network is able to reproduce existing reconstructions with a high level of accuracy, as measured by several metrics.

  7. ExRET-Opt: An automated exergy/exergoeconomic simulation framework for building energy retrofit analysis and design optimisation

    International Nuclear Information System (INIS)

    García Kerdan, Iván; Raslan, Rokia; Ruyssevelt, Paul; Morillón Gálvez, David

    2017-01-01

    Highlights: • Development of a building retrofit-oriented exergoeconomic-based optimisation tool. • A new exergoeconomic cost-benefit indicator is developed for design comparison. • Thermodynamic and thermal comfort variables used as constraints and/or objectives. • Irreversibilities and exergetic cost for end-use processes are substantially reduced. • Robust methodology that should be pursued in everyday building retrofit practice. - Abstract: Energy simulation tools have a major role in the assessment of building energy retrofit (BER) measures. Exergoeconomic analysis and optimisation is a common practice in sectors such as the power generation and chemical processes, aiding engineers to obtain more energy-efficient and cost-effective energy systems designs. ExRET-Opt, a retrofit-oriented modular-based dynamic simulation framework has been developed by embedding a comprehensive exergy/exergoeconomic calculation method into a typical open-source building energy simulation tool (EnergyPlus). The aim of this paper is to show the decomposition of ExRET-Opt by presenting modules, submodules and subroutines used for the framework’s development as well as verify the outputs with existing research data. In addition, the possibility to perform multi-objective optimisation analysis based on genetic-algorithms combined with multi-criteria decision making methods was included within the simulation framework. This addition could potentiate BER design teams to perform quick exergy/exergoeconomic optimisation, in order to find opportunities for thermodynamic improvements along the building’s active and passive energy systems. The enhanced simulation framework is tested using a primary school building as a case study. Results demonstrate that the proposed simulation framework provide users with thermodynamic efficient and cost-effective designs, even under tight thermodynamic and economic constraints, suggesting its use in everyday BER practice.

  8. Denoising multicriterion iterative reconstruction in emission spectral tomography

    Science.gov (United States)

    Wan, Xiong; Yin, Aihan

    2007-03-01

    In the study of optical testing, the computed tomogaphy technique has been widely adopted to reconstruct three-dimensional distributions of physical parameters of various kinds of fluid fields, such as flame, plasma, etc. In most cases, projection data are often stained by noise due to environmental disturbance, instrumental inaccuracy, and other random interruptions. To improve the reconstruction performance in noisy cases, an algorithm that combines a self-adaptive prefiltering denoising approach (SPDA) with a multicriterion iterative reconstruction (MCIR) is proposed and studied. First, the level of noise is approximately estimated with a frequency domain statistical method. Then the cutoff frequency of a Butterworth low-pass filter was established based on the evaluated noise energy. After the SPDA processing, the MCIR algorithm was adopted for limited-view optical computed tomography reconstruction. Simulated reconstruction of two test phantoms and a flame emission spectral tomography experiment were employed to evaluate the performance of SPDA-MCIR in noisy cases. Comparison with some traditional methods and experiment results showed that the SPDA-MCIR combination had obvious improvement in the case of noisy data reconstructions.

  9. Noninvasive coronary angioscopy using electron beam computed tomography and multidetector computed tomography

    NARCIS (Netherlands)

    van Ooijen, PMA; Nieman, K; de Feyter, PJ; Oudkerk, M

    2002-01-01

    With the advent of noninvasive coronary imaging techniques like multidetector computed tomography and electron beam computed tomography, new representation methods such as intracoronary visualization. have been introduced. We explore the possibilities of these novel visualization techniques and

  10. The effect of iterative reconstruction on computed tomography assessment of emphysema, air trapping and airway dimensions

    NARCIS (Netherlands)

    Mets, Onno M.; Willemink, Martin J.; de Kort, Freek P. L.; Mol, Christian P.; Leiner, Tim; Oudkerk, Matthijs; Prokop, Mathias; de Jong, Pim A.

    2012-01-01

    To determine the influence of iterative reconstruction (IR) on quantitative computed tomography (CT) measurements of emphysema, air trapping, and airway wall and lumen dimensions, compared to filtered back-projection (FBP). Inspiratory and expiratory chest CTs of 75 patients (37 male, 38 female;

  11. The TMS34010 graphic processor - an architecture for image visualization in NMR tomography

    International Nuclear Information System (INIS)

    Slaets, Jan Frans Willem; Paiva, Maria Stela Veludo de; Almeida, Lirio O.B.

    1989-01-01

    This abstract presents a description of the minimum system implemented with the graphic processor TMS34010, which will be used in the reconstruction, treatment and interpretation f images obtained by NMR tomography. The project is being developed in the LIE (Electronic Instrumentation Laboratory), of the Sao Carlos Chemistry and Physical Institute, S P, Brazil and is already in operation

  12. Gamma tomography apparatus

    International Nuclear Information System (INIS)

    Span, F.J.

    1988-01-01

    The patent concerns a gamma tomography apparatus for medical diagnosis. The apparatus comprises a gamma scintillation camera head and a suspension system for supporting and positioning the camera head with respect for the patient. Both total body scanning and single photon emission tomography can be carried out with the apparatus. (U.K.)

  13. Computerised Axial Tomography (CAT)

    Science.gov (United States)

    1990-06-01

    Ministry of’ Defence, Defence Research Information Centre, UK. Computerised Axial Tomography ( CAT ) Report Secufty C"uMiauion tide Onadtiicadon (U. R, Cor S...DRIC T 8485 COMPUTERISED AXIAL TOMOGRAPHY ( CAT ) F.P. GENTILE, F. SABETTA, V. TRO1* ISS R 78/4.Rome, 1.5 Mlarch 1978 (from Italian) B Distribution(f...dello Radiazioni ISSN 0390--6477 F.P. GENTILE, F. SABETTA. V. TROI Computerised Axial Tomography ( CAT ) March 15, 1978). This paper is a review of

  14. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... Stroke Brain Tumors Computer Tomography (CT) Safety During Pregnancy Head and Neck Cancer X-ray, Interventional Radiology and Nuclear Medicine Radiation Safety Images related to Computed Tomography (CT) - ...

  15. Attenuated Vector Tomography -- An Approach to Image Flow Vector Fields with Doppler Ultrasonic Imaging

    International Nuclear Information System (INIS)

    Huang, Qiu; Peng, Qiyu; Huang, Bin; Cheryauka, Arvi; Gullberg, Grant T.

    2008-01-01

    The measurement of flow obtained using continuous wave Doppler ultrasound is formulated as a directional projection of a flow vector field. When a continuous ultrasound wave bounces against a flowing particle, a signal is backscattered. This signal obtains a Doppler frequency shift proportional to the speed of the particle along the ultrasound beam. This occurs for each particle along the beam, giving rise to a Doppler velocity spectrum. The first moment of the spectrum provides the directional projection of the flow along the ultrasound beam. Signals reflected from points further away from the detector will have lower amplitude than signals reflected from points closer to the detector. The effect is very much akin to that modeled by the attenuated Radon transform in emission computed tomography.A least-squares method was adopted to reconstruct a 2D vector field from directional projection measurements. Attenuated projections of only the longitudinal projections of the vector field were simulated. The components of the vector field were reconstructed using the gradient algorithm to minimize a least-squares criterion. This result was compared with the reconstruction of longitudinal projections of the vector field without attenuation. If attenuation is known, the algorithm was able to accurately reconstruct both components of the full vector field from only one set of directional projection measurements. A better reconstruction was obtained with attenuation than without attenuation implying that attenuation provides important information for the reconstruction of flow vector fields.This confirms previous work where we showed that knowledge of the attenuation distribution helps in the reconstruction of MRI diffusion tensor fields from fewer than the required measurements. In the application of ultrasound the attenuation distribution is obtained with pulse wave transmission computed tomography and flow information is obtained with continuous wave Doppler

  16. Analysis of an industrial process simulator column using third-generation computed tomography

    International Nuclear Information System (INIS)

    Kirita, Rodrigo; Carvalho, Diego Vergacas de Sousa; Mesquita, Carlos Henrique de; Vasquez, Pablo Antonio S.; Hamada, Margarida Mizue

    2011-01-01

    The CT methodology must be tested using a simulator column in the laboratory before applying it in the industrial plants. In this work, using the third-generation industrial computed tomography developed at the IPEN, a gas absorption column, used as a simulator column for industrial process was evaluated. It is a glass cylindrical tube of 90 mm diameter and 1400 mm height constituted the following parts: random packed column, liquid circuit (water), gas circuit and analysis was used as a simulator column. Gamma ray tomography experiments were carried out, using this simulator column empty and filled with water. In this work the scanner was setting for 90 views and 19 projections for each detector totalizing 11970 projections. The resulting images describe the presence of liquid or gas phases and are possible to evaluate the linear attenuation coefficients inside the column. In this case, linear attenuation coefficient for water was 0.0813 cm-1. It was established that the newly developed third-generation fan-beam arrangement gamma scanner unit has a good spatial resolution acceptable given the size of the column used in this study. (author)

  17. Computed tomography in facial trauma

    International Nuclear Information System (INIS)

    Zilkha, A.

    1982-01-01

    Computed tomography (CT), plain radiography, and conventional tomography were performed on 30 patients with facial trauma. CT demonstrated bone and soft-tissue involvement. In all cases, CT was superior to tomography in the assessment of facial injury. It is suggested that CT follow plain radiography in the evaluation of facial trauma

  18. Value of computed tomography for evaluating the sub glottis in laryngeal and hypopharyngeal squamous cell carcinoma

    International Nuclear Information System (INIS)

    Souza, Ricardo Pires de; Barros, Nestor de; Paes Junior, Ademar Jose de Oliveira; Tornin, Olger de Souza; Rapoport, Abrao; Cerri, Giovanni Guido

    2007-01-01

    Context And Objective: Sub glottic involvement in squamous cell carcinoma is a determining factor for contraindicating conservative partial surgery. The subglottis is easily identified by axial computed tomography sections. The present study aimed to evaluate the occurrence of false-negative and false-positive results, and the overall accuracy of staging by computed tomography, in order to detect the involvement of the subglottic laryngeal compartment, in cases of laryngeal and hypopharyngeal squamous cell carcinoma. Design And Setting: Retrospective, non-randomized study of patients treated at Hospital Heliopolis, Sao Paulo, Brazil. Methods: Computed tomography scans were performed on third-generation equipment with 5-mm slice thickness. Afterwards, all patients underwent surgical and anatomopathological examinations as the gold standard procedures. Results: Among 60 patients, 14 were diagnosed with subglottic extension by surgical and histopathological examination. There were three false-negative and no false-positive results from computed tomography scans. The sensitivity and negative predictive value were 100.0%. Accuracy was 95.0%, specificity was 93.5% and positive predictive value was 82.4%. Conclusions: Computed tomography could serve as a powerful auxiliary method for staging laryngeal and hypopharyngeal cancer. However, precautions should be taken in analyzing computed tomography scan data, because vegetating lesions may also be projected into the subglottic compartment, without real involvement of the subglottis, which may cause a false-positive result. (author)

  19. Value of computed tomography for evaluating the sub glottis in laryngeal and hypopharyngeal squamous cell carcinoma

    Energy Technology Data Exchange (ETDEWEB)

    Souza, Ricardo Pires de; Barros, Nestor de; Paes Junior, Ademar Jose de Oliveira; Tornin, Olger de Souza; Rapoport, Abrao; Cerri, Giovanni Guido [Hospital Heliopolis, Sao Paulo, SP (Brazil). Dept. de Cirurgia de Cabeca e Pescoco, Otorrinolaringologia e Imagem]. E-mail: ricapires@ig.com.br; olger1@uol.com.br

    2007-03-15

    Context And Objective: Sub glottic involvement in squamous cell carcinoma is a determining factor for contraindicating conservative partial surgery. The subglottis is easily identified by axial computed tomography sections. The present study aimed to evaluate the occurrence of false-negative and false-positive results, and the overall accuracy of staging by computed tomography, in order to detect the involvement of the subglottic laryngeal compartment, in cases of laryngeal and hypopharyngeal squamous cell carcinoma. Design And Setting: Retrospective, non-randomized study of patients treated at Hospital Heliopolis, Sao Paulo, Brazil. Methods: Computed tomography scans were performed on third-generation equipment with 5-mm slice thickness. Afterwards, all patients underwent surgical and anatomopathological examinations as the gold standard procedures. Results: Among 60 patients, 14 were diagnosed with subglottic extension by surgical and histopathological examination. There were three false-negative and no false-positive results from computed tomography scans. The sensitivity and negative predictive value were 100.0%. Accuracy was 95.0%, specificity was 93.5% and positive predictive value was 82.4%. Conclusions: Computed tomography could serve as a powerful auxiliary method for staging laryngeal and hypopharyngeal cancer. However, precautions should be taken in analyzing computed tomography scan data, because vegetating lesions may also be projected into the subglottic compartment, without real involvement of the subglottis, which may cause a false-positive result. (author)

  20. Fluorodeoxyglucose Positron Emission Tomography-Computed Tomography in Disseminated Cryptococcosis.

    Science.gov (United States)

    Tripathy, Sarthak; Parida, Girish Kumar; Roy, Shambo Guha; Singhal, Abhinav; Mallick, Saumya Ranjan; Tripathi, Madhavi; Shamim, Shamim Ahmed

    2017-01-01

    Disseminated cryptococcosis without pulmonary involvement is a very rare phenomenon. Patterns of organ involvement in cryptococcosis resemble various other infective conditions as well as malignant conditions on fluorodeoxyglucose positron emission tomography-computed tomography. We present a case of a 43-year-old male patient who had disseminated cryptococcosis. The rarity of the case being noninvolvement of lungs and meninges and resembling more like lymphoma due to the diffuse involvement of the lymph nodes on both sides of the diaphragm.