WorldWideScience

Sample records for project number 99-119

  1. NERI PROJECT 99-119. TASK 2. DATA-DRIVEN PREDICTION OF PROCESS VARIABLES. FINAL REPORT

    Energy Technology Data Exchange (ETDEWEB)

    Upadhyaya, B.R.

    2003-04-10

    This report describes the detailed results for task 2 of DOE-NERI project number 99-119 entitled ''Automatic Development of Highly Reliable Control Architecture for Future Nuclear Power Plants''. This project is a collaboration effort between the Oak Ridge National Laboratory (ORNL,) The University of Tennessee, Knoxville (UTK) and the North Carolina State University (NCSU). UTK is the lead organization for Task 2 under contract number DE-FG03-99SF21906. Under task 2 we completed the development of data-driven models for the characterization of sub-system dynamics for predicting state variables, control functions, and expected control actions. We have also developed the ''Principal Component Analysis (PCA)'' approach for mapping system measurements, and a nonlinear system modeling approach called the ''Group Method of Data Handling (GMDH)'' with rational functions, and includes temporal data information for transient characterization. The majority of the results are presented in detailed reports for Phases 1 through 3 of our research, which are attached to this report.

  2. IMRT Commissioning: application of the AAPM's TG-119; Comissionamento de IMRT: aplicacao do TG-119 da AAPM

    Energy Technology Data Exchange (ETDEWEB)

    Zeppellini, Caroline; Furnari, Laura, E-mail: laurafurnari@hotmail.com [Universidade de Sao Paulo (USP), Sao Paulo, SP (Brazil). Fac. de Medicina. Inst. de Radiologia

    2013-08-15

    In order to verify the commissioning of the planning of intensity-modulated radiation therapy system (IMRT), the TG-119 of the American Association of Physicists in Medicine (AAPM) was applied. Using pre defined targets and normal structures, plans were realized, absolute and relative dose were measured with an ionizing chamber and films, and the results were compared with planned values. The maximum deviation of the measurements with the ionization chamber was 3,6%, but, in the total eleven measurements, only two were bigger than the tolerance limit of 3%, recommended by TG-119. The number of points which passed criteria gamma 3% to 3 mm ranged between 96.36% and 99.92%, all measurements were within the recommended 95%. The confidence limits found for both film and for chamber were lower than those achieved in the TG-119. Our results showed a good concordance with TG-119, what means that the system is adequate for clinical applications. (author)

  3. 23 CFR 636.119 - How does this part apply to a project developed under a public-private partnership?

    Science.gov (United States)

    2010-04-01

    ... public-private partnership? 636.119 Section 636.119 Highways FEDERAL HIGHWAY ADMINISTRATION, DEPARTMENT... does this part apply to a project developed under a public-private partnership? (a) In order for a... Federal-aid procurement procedures will depend on the nature of the public-private agreement. (1) If the...

  4. Synthesis of [119mSn]-mesoporphyrin IX dichloride

    International Nuclear Information System (INIS)

    Denissen, J.F.

    1990-01-01

    Tin mesoporphyrin IX dichloride (Sn-MPCl 2 ) is a heme oxygenase inhibitor of current clinical interest for the treatment of neonatal hyperbilirubinemia. The synthesis of [ 119m Sn]-MPCl 2 for drug metabolism and disposition studies is reported. [ 119m Sn]-MPCl 2 was prepared in 60% radiochemical yield by metalation of the porphyrin nucleus of mesoporphyrin IX dihydrochloride with tin(II)-119m acetate. The product had a specific activity of 43.4 mCi/mmol and a radiochemical purity of 99%, as determined by radio-HPLC analysis. (author)

  5. NERI PROJECT 99-119. TASK 1. ADVANCED CONTROL TOOLS AND METHODS. FINAL REPORT

    Energy Technology Data Exchange (ETDEWEB)

    March-Leuba, J.A.

    2002-09-09

    Nuclear plants of the 21st century will employ higher levels of automation and fault tolerance to increase availability, reduce accident risk, and lower operating costs. Key developments in control algorithms, fault diagnostics, fault tolerance, and communication in a distributed system are needed to implement the fully automated plant. Equally challenging will be integrating developments in separate information and control fields into a cohesive system, which collectively achieves the overall goals of improved performance, safety, reliability, maintainability, and cost-effectiveness. Under the Nuclear Energy Research Initiative (NERI), the U. S. Department of Energy is sponsoring a project to address some of the technical issues involved in meeting the long-range goal of 21st century reactor control systems. This project, ''A New Paradigm for Automated Development Of Highly Reliable Control Architectures For Future Nuclear Plants,'' involves researchers from Oak Ridge National Laboratory, University of Tennessee, and North Carolina State University. This paper documents a research effort to develop methods for automated generation of control systems that can be traced directly to the design requirements. Our final goal is to allow the designer to specify only high-level requirements and stress factors that the control system must survive (e.g. a list of transients, or a requirement to withstand a single failure.) To this end, the ''control engine'' automatically selects and validates control algorithms and parameters that are optimized to the current state of the plant, and that have been tested under the prescribed stress factors. The control engine then automatically generates the control software from validated algorithms. Examples of stress factors that the control system must ''survive'' are: transient events (e.g., set-point changes, or expected occurrences such a load rejection,) and postulated

  6. 2020 Vision Project Summary: FY99

    Energy Technology Data Exchange (ETDEWEB)

    K.W. Gordon; K.P. Scott

    2000-01-01

    During the 1998-99 school year, students from participating schools completed and submitted a variety of scenarios describing potential world and regional conditions in the year 2020 and their possible effect on U.S. national security. This report summarizes the student's views and describes trends observed over the course of the 2020 Vision project's four years.

  7. Number projection method

    International Nuclear Information System (INIS)

    Kaneko, K.

    1987-01-01

    A relationship between the number projection and the shell model methods is investigated in the case of a single-j shell. We can find a one-to-one correspondence between the number projected and the shell model states

  8. The decay of $]^{119}$Cd and $\\^{119}$In isomers

    CERN Document Server

    Scheidemann, O; Patzelt, P

    1976-01-01

    The decay of /sup 119g, m/Cd and /sup 119g, m/In has been investigated using isotopically separated samples produced by the ISOLDE facility at CERN. The half-lives are 2.69+or-0.02 min, 2.20+or-0.02 min, 2.4+or-0.1 min and 18.0+or-0.3 min, respectively. A total of 33 excited levels have been found in /sup 119/In and 4 excited levels have been found in /sup 119/Sn. The percentage isomeric transition in /sup 119/In has been measured to be 2.5/sub -0.3//sup +0.5/%. The possibility of rotational and vibrational levels in /sup 119/In is discussed. (32 refs).

  9. COMPARISON OF TREND PROJECTION METHODS AND BACKPROPAGATION PROJECTIONS METHODS TREND IN PREDICTING THE NUMBER OF VICTIMS DIED IN TRAFFIC ACCIDENT IN TIMOR TENGAH REGENCY, NUSA TENGGARA

    Directory of Open Access Journals (Sweden)

    Aleksius Madu

    2016-10-01

    Full Text Available The purpose of this study is to predict the number of traffic accident victims who died in Timor Tengah Regency with Trend Projection method and Backpropagation method, and compare the two methods based on the degree of guilt and predict the number traffic accident victims in the Timor Tengah Regency for the coming year. This research was conducted in Timor Tengah Regency where data used in this study was obtained from Police Unit in Timor Tengah Regency. The data is on the number of traffic accidents in Timor Tengah Regency from 2000 – 2013, which is obtained by a quantitative analysis with Trend Projection and Backpropagation method. The results of the data analysis predicting the number of traffic accidents victims using Trend Projection method obtained the best model which is the quadratic trend model with equation Yk = 39.786 + (3.297 X + (0.13 X2. Whereas by using back propagation method, it is obtained the optimum network that consists of 2 inputs, 3 hidden screens, and 1 output. Based on the error rates obtained, Back propagation method is better than the Trend Projection method which means that the predicting accuracy with Back propagation method is the best method to predict the number of traffic accidents victims in Timor Tengah Regency. Thus obtained predicting the numbers of traffic accident victims for the next 5 years (Years 2014-2018 respectively - are 106 person, 115 person, 115 person, 119 person and 120 person.   Keywords: Trend Projection, Back propagation, Predicting.

  10. Project CHECO Southeast Asia Report. OV-1/AC-119 Hunter-Killer Team

    Science.gov (United States)

    1972-10-10

    between Phan Rang, Phu Cat , and Danang in order to provide best coverage of the Vietnamese conflict. -- On 16 February 1970, three AC -ll9Ks and 70...SOUTHEAST ASIA D D DDiv AY/XDOSQA I OV-1/ AC -119 " i IWB I HUNTER-KILLER TEAM 19’.1’ CONTINUING REPORT CLASSIFIED Ey 7AFIDOOC DOWNGRADE TjU SECRET...xamination of C urrent, 0 per’tions I~ I fF!lr T I TII TIIII I OV=1/ AC -119 HUNTER-KILLER TEAMI 1 10 OCTOBER 1972 HQ PACAF Directorate of Operations

  11. The Supply of Medical Radioisotopes. 2016 Medical Isotope Supply Review: 99Mo/99mTc Market Demand and Production Capacity Projection 2016-2021

    International Nuclear Information System (INIS)

    Charlton, Kevin; )

    2016-03-01

    Medical diagnostic imaging techniques using technetium-99m ( 99 mTc) account for approximately 80% of all nuclear medicine procedures, representing 30-40 million examinations Worldwide every year. Disruptions in the supply chain of these medical isotopes - which have half-lives of 66 hours for molybdenum-99 ( 99 Mo) and only 6 hours for 99m Tc, and thus must be produced continuously - can lead to cancellations or delays in important medical testing services. Supply reliability has been challenged over the past decade due to unexpected shutdowns and extended refurbishment periods at some of the 99 Mo-producing research reactors and processing facilities. These shutdowns have at times created conditions for extended global supply shortages (e.g. 2009-2010). At the request of its member countries, the Nuclear Energy Agency (NEA) became involved in global efforts to ensure a secure supply of 99 Mo/ 99m Tc. Since June 2009, the NEA and its High-level Group on the Security of Supply of Medical Radioisotopes (HLG-MR) have examined the causes of supply shortages and developed a policy approach, including principles and supporting recommendations to address those causes. The NEA has also reviewed the global 99 Mo supply situation periodically, to highlight periods of potential reduced supply and to underscore the case for implementing the HLG-MR policy approach in a timely and globally consistent manner. In 2012, the NEA released a 99 Mo supply and demand forecast up to 2030, identifying periods of potential low supply relative to demand. That 2012 forecast was updated with a report in 2014 that focused on the much shorter 2015-2020 period. That report was updated in 2015 with a report, '2015 Medical Isotope Supply Review: 99 Mo/ 99m Tc Market Demand and Production Capacity Projection 2015-2020' (NEA, 2015), which focused on the same period. This report updates the 2015 report, and focuses on the important 2016-2021 period. At the end of 2015, the OSIRIS reactor

  12. Final Report for DOE Project DE-FC07-99CH11010

    Energy Technology Data Exchange (ETDEWEB)

    Jed Randall; Robert Kean

    2003-10-22

    Department of Energy award number DE-FC07-99CH11010, Enhanced Utilization of Corn Based Biomaterials, supported a technology development program sponsored by Cargill Dow LLC from September 30, 1999 through June 30, 2003. The work involved fundamental scientific studies on poly lactic acid (PLA), a new environmentally benign plastic material from renewable resources. DOE funds supported academic research at the Colorado School of Mines and the National Renewable Energy Laboratory (NREL), and industry cost share was directed towards applied research into new product development utilizing the fundamental information generated by the academic partners. Under the arrangement of the grant, the fundamental information is published so that other companies can utilize it in evaluating the applicability of PLA in their own products. The overall project objective is to increase the utilization of PLA, a renewable resource based plastic, currently produced from fermented corn sugar.

  13. BKP and projective Hurwitz numbers

    Science.gov (United States)

    Natanzon, Sergey M.; Orlov, Aleksandr Yu.

    2017-06-01

    We consider d-fold branched coverings of the projective plane RP^2 and show that the hypergeometric tau function of the BKP hierarchy of Kac and van de Leur is the generating function for weighted sums of the related Hurwitz numbers. In particular, we get the RP^2 analogues of the CP^1 generating functions proposed by Okounkov and by Goulden and Jackson. Other examples are Hurwitz numbers weighted by the Hall-Littlewood and by the Macdonald polynomials. We also consider integrals of tau functions which generate Hurwitz numbers related to base surfaces with arbitrary Euler characteristics sc {e}, in particular projective Hurwitz numbers sc {e}=1.

  14. Medical Surveillance Monthly Report (MSMR). Volume 15, Number 1, January 2008

    Science.gov (United States)

    2008-01-01

    108.8 138.3 1.26 22.34 Idaho 60 99.8 51.9 1.16 13.40 Montana 69 119.5 49.9 1.38 33.13 New Mexico 72 78.6 79.1 0.91 -7.78 Nevada 96 142.3...May 2004. Note: Completeness and timeliness of reporting vary by facility. Shigella Hepatitis B Varicella Reporting locations Number of reports all... Varicella Reporting locations Number of reports all events† Food-borne Vaccine preventable Campylo- bacter Giardia Salmonella 24 VOL. 15 / NO. 1

  15. Use of 99mTc mercaptoacetyltriglycine (MAG3) for detection of renal lesions after ESWL

    International Nuclear Information System (INIS)

    Schaub, T.; Witsch, U.; El-Damanhoury, H.; Naegele-Woehrle, B.; Hahn, K.

    1992-01-01

    Extracorporeal shock wave lithotripsy (ESWL) has become the treatment of choice for urinary calculi. 117 patients were studied prospectively with 99m Tc Mercaptoacetyltriglycine (MAG3) before and after ESWL. 79 (66%) of the 119 kidneys treated had abnormal findings. Of these 63/119 (53%) had abnormal scans. 41 (65%) had focal lesions with a delayed intrarenal transport. The remaining 22 had a diffuse delay of intrarenal transport. A loss of relative renal function of 3% and more compared to the pretreatment values was observed in 50/119 (42%) patients. 99m Tc MAG3 should be done routinely together with radiologic tests (CT or MRI) before and after ESWL to select the patients at risk for post ESWL hypertension. (orig.) [de

  16. The Supply of Medical Radioisotopes. 2015 Medical Isotope Supply Review: 99Mo/99mTc Market Demand and Production Capacity Projection 2015-2020

    International Nuclear Information System (INIS)

    Charlton, Kevin; )

    2015-08-01

    -2020 period. In that period, the OSIRIS reactor in France will permanently shut down operations and one of the largest irradiators for medical isotopes, the National Research Universal (NRU) reactor in Canada, will cease routine 99 Mo production and the associated Canadian processing capacity will move offline. In the same period, new reactor- and non-reactor-based 99 Mo/ 99m Tc projects are expected to be commissioned in various countries. It is important to analyse the overall impact and timing of these events to understand how global production capacity might be affected. This report presents global irradiation and processing capacity under three main capacity scenarios. As in the previous 2014 report, the projected demand and production capacity are presented in six-month intervals (January-June and July-December) during the forecast period. The NEA recognises that, as forecast time intervals decrease (e.g. from one year to six months), the timing accuracy of the forecast events may also decrease. The results in this report, however, should be interpreted in terms of the projected future trends as opposed to actual forecast values and dates

  17. 28 CFR 0.119 - Organization.

    Science.gov (United States)

    2010-07-01

    ... 28 Judicial Administration 1 2010-07-01 2010-07-01 false Organization. 0.119 Section 0.119 Judicial Administration DEPARTMENT OF JUSTICE ORGANIZATION OF THE DEPARTMENT OF JUSTICE 1-Office of Community Oriented Policing Services § 0.119 Organization. The Office of Community Oriented Policing...

  18. Photon number projection using non-number-resolving detectors

    International Nuclear Information System (INIS)

    Rohde, Peter P; Webb, James G; Huntington, Elanor H; Ralph, Timothy C

    2007-01-01

    Number-resolving photo-detection is necessary for many quantum optics experiments, especially in the application of entangled state preparation. Several schemes have been proposed for approximating number-resolving photo-detection using non-number-resolving detectors. Such techniques include multi-port detection and time-division multiplexing. We provide a detailed analysis and comparison of different number-resolving detection schemes, with a view to creating a useful reference for experimentalists. We show that the ideal architecture for projective measurements is a function of the detector's dark count and efficiency parameters. We also describe a process for selecting an appropriate topology given actual experimental component parameters

  19. 75 FR 54226 - Proposed Collection; Comment Request for Notice 98-52 and REG-108639-99

    Science.gov (United States)

    2010-09-03

    ... Notice 98-52 and REG- 108639-99 AGENCY: Internal Revenue Service (IRS), Treasury. ACTION: Notice and... proposed rulemaking, REG-108639-99, Retirement Plans; Cash or Deferred Arrangements Under Section 401(k.... Regulation Project Number: REG-108639-99. Abstract: This notice provides guidance to plan administrators...

  20. Use of [sup 99m]Tc mercaptoacetyltriglycine (MAG3) for detection of renal lesions after ESWL. A prospective study with 117 patients. [sup 99m]Technetium-Mercaptoacetyltriglycin (MAG3) zum Nachweis von Nierenveraenderungen nach extrakorporealer Stosswellenlithotripsie. Eine prospektive Untersuchung bei 117 Patienten

    Energy Technology Data Exchange (ETDEWEB)

    Schaub, T. (Klinik mit Poliklinik fuer Radiologie, Universitaetsklinik Mainz (Germany)); Witsch, U.; El-Damanhoury, H. (Klinik mit Poliklinik fuer Urologie, Universitaetsklinik Mainz (Germany)); Naegele-Woehrle, B.; Hahn, K. (Klinik mit Poliklinik fuer Nuklearmedizin, Universitaetsklinik Mainz (Germany))

    1992-10-01

    Extracorporeal shock wave lithotripsy (ESWL) has become the treatment of choice for urinary calculi. 117 patients were studied prospectively with [sup 99m]Tc Mercaptoacetyltriglycine (MAG3) before and after ESWL. 79 (66%) of the 119 kidneys treated had abnormal findings. Of these 63/119 (53%) had abnormal scans. 41 (65%) had focal lesions with a delayed intrarenal transport. The remaining 22 had a diffuse delay of intrarenal transport. A loss of relative renal function of 3% and more compared to the pretreatment values was observed in 50/119 (42%) patients. [sup 99m]Tc MAG3 should be done routinely together with radiologic tests (CT or MRI) before and after ESWL to select the patients at risk for post ESWL hypertension. (orig.).

  1. Product-Improvement Test (Phase II), Jetcal Tester, Model H119A.

    Science.gov (United States)

    1969-03-05

    Ao—A0 51 113 ARMY AVIATION ‘Cs’ BOARD FORT tUCKER ALA — P*OOUCTeII ROVEMCNT TEST ( FHAS ~ I I ) . JETCAL TESTER, MODEL M119A~~’ETC(U) MAR S9...Phase i i ) , Jetcal Tester , Model H 119A , USATECOM Project No. 4-6-5011-03 b . No fur ther consideration be given to the TEMPCAL heater probe as a...essen t i a l component of the Jetcal Tester. e. The service manual instruct ions for con t inu i ty te s t ing of EG1 thermocouples be revised to

  2. GPR119 agonists: a promising approach for T2DM treatment? A SWOT analysis of GPR119.

    Science.gov (United States)

    Kang, Sang-Uk

    2013-12-01

    Ever since its advent as a promising therapeutic target for type 2 diabetes mellitus (T2DM), G-protein-coupled receptor 119 (GPR119) has received much interest from the pharmaceutical industry. This interest peaked in June 2010, when Sanofi-Aventis agreed to pay Metabolex (Cymabay Therapeutics) US$375 million for MBX-2982, which was a representative orally active GPR119 agonist. However, Sanofi-Aventis opted to terminate the deal in May 2011 and another leading GPR119 agonist, GSK1292263, had a loss of efficacy during its clinical trial. In this review, I discuss the pros and cons of GPR119 through a strengths, weaknesses, opportunities, and threats (SWOT) analysis and propose development strategies for the eventual success of a GPR119 agonist development program. Copyright © 2013 Elsevier Ltd. All rights reserved.

  3. 45 CFR 400.119 - Interstate movement.

    Science.gov (United States)

    2010-10-01

    ... 45 Public Welfare 2 2010-10-01 2010-10-01 false Interstate movement. 400.119 Section 400.119... Services § 400.119 Interstate movement. After the initial placement of an unaccompanied minor, the same procedures that govern the movement of nonrefugee foster cases to other States apply to the movement of...

  4. 46 CFR 119.420 - Engine cooling.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 4 2010-10-01 2010-10-01 false Engine cooling. 119.420 Section 119.420 Shipping COAST... Machinery Requirements § 119.420 Engine cooling. (a) Except as otherwise provided in paragraph (b) of this section, all engines must be water cooled and meet the requirements of this paragraph. (1) The engine head...

  5. 46 CFR 119.520 - Bilge pumps.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 4 2010-10-01 2010-10-01 false Bilge pumps. 119.520 Section 119.520 Shipping COAST... Ballast Systems § 119.520 Bilge pumps. (a) Each vessel must be provided with bilge pumps in accordance... have a portable hand bilge pump that must be: (1) Capable of pumping water, but not necessarily...

  6. Approximate particle number projection in hot nuclei

    International Nuclear Information System (INIS)

    Kosov, D.S.; Vdovin, A.I.

    1995-01-01

    Heated finite systems like, e.g., hot atomic nuclei have to be described by the canonical partition function. But this is a quite difficult technical problem and, as a rule, the grand canonical partition function is used in the studies. As a result, some shortcomings of the theoretical description appear because of the thermal fluctuations of the number of particles. Moreover, in nuclei with pairing correlations the quantum number fluctuations are introduced by some approximate methods (e.g., by the standard BCS method). The exact particle number projection is very cumbersome and an approximate number projection method for T ≠ 0 basing on the formalism of thermo field dynamics is proposed. The idea of the Lipkin-Nogami method to perform any operator as a series in the number operator powers is used. The system of equations for the coefficients of this expansion is written and the solution of the system in the next approximation after the BCS one is obtained. The method which is of the 'projection after variation' type is applied to a degenerate single j-shell model. 14 refs., 1 tab

  7. 46 CFR 119.320 - Water heaters.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 4 2010-10-01 2010-10-01 false Water heaters. 119.320 Section 119.320 Shipping COAST... Machinery § 119.320 Water heaters. (a) A water heater must meet the requirements of Parts 53 and 63 in... electric water heater is also acceptable if it: (1) Has a capacity of not more than 454 liters (120 gallons...

  8. Mo-99 production by fission and future projections

    International Nuclear Information System (INIS)

    Carranza, E.C.; Novello, A.; Bronca, M.; Cestau, D.; Bavaro, R.; Centurion, R.; Bravo, C.; Bronca, P.; Gualda, E.; Fraguas, F.; Giomi, A.; Ivaldi, L.

    2012-01-01

    Description of the I-131 and Mo-99 production process: The process starts with the irradiation of uranium-aluminum mini plates in the RA-3, Argentinean Reactor No.3, Ezeiza Atomic Center. In a nuclear reactor there is a constant flow of neutrons and when a neutron with proper energy impacts on a nucleus of U-235, it is absorbed at the same time generate an unstable configuration nuclear. For this reason, the nucleus formed is fission, getting two different atoms. Approximately 6% of the fissions produce Mo-99 and 3% produce I-131; the percentage remaining corresponds to formation of atoms without interest for use in medicine. In conclusion, the objective of the process developed in the Fission Plant, is starting from uranium mini plates, separate the Mo-99 and I-131 generated, the remaining elements formed. - Evolution of Mo-99 Production in the last 10 years: The Fission Mo-99 Plant Production begins routine production of Mo-99 in 1985, using targets made of uranium enriched at 90% U-235. In the 1990s, global concern regarding the use of highly enriched uranium, due to non-proliferation issues, caused the interruption of supply of nuclear material (HEU enriched at 90% of U-235). Following this, Argentina developed target based on low-enriched uranium (less than 20% U-235), becoming in 2002 the first country in the world to produce Mo-99 with LEU targets. From 2002 to date, the activity produced of Mo-99 has been tripled annually (author)

  9. 41 CFR 61-250.99 - What is the OMB control number for this part?

    Science.gov (United States)

    2010-07-01

    ... 41 Public Contracts and Property Management 1 2010-07-01 2010-07-01 true What is the OMB control... TRAINING SERVICE, DEPARTMENT OF LABOR 250-ANNUAL REPORT FROM FEDERAL CONTRACTORS § 61-250.99 What is the OMB control number for this part? Pursuant to the Paperwork Reduction Act, 44 U.S.C. 3501 et seq., and...

  10. 41 CFR 61-300.99 - What is the OMB control number for this part?

    Science.gov (United States)

    2010-07-01

    ... 41 Public Contracts and Property Management 1 2010-07-01 2010-07-01 true What is the OMB control... TRAINING SERVICE, DEPARTMENT OF LABOR 300-ANNUAL REPORT FROM FEDERAL CONTRACTORS § 61-300.99 What is the OMB control number for this part? Pursuant to the Paperwork Reduction Act, 44 U.S.C. 3501 et seq., and...

  11. 13 CFR 119.2 - Definitions.

    Science.gov (United States)

    2010-01-01

    ... entrepreneurs, such as, but not limited to, assistance intended to enhance business planning, marketing, management, financial management skills, business operations, or assistance for the purpose of increasing... 13 Business Credit and Assistance 1 2010-01-01 2010-01-01 false Definitions. 119.2 Section 119.2...

  12. 49 CFR 41.119 - DOT regulated buildings.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 1 2010-10-01 2010-10-01 false DOT regulated buildings. 41.119 Section 41.119 Transportation Office of the Secretary of Transportation SEISMIC SAFETY § 41.119 DOT regulated buildings. (a) Each DOT Operating Administration with responsibility for regulating the structural safety of buildings...

  13. Temperature-dependent particle-number projected moment of inertia

    International Nuclear Information System (INIS)

    Allal, N. H.; Fellah, M.; Benhamouda, N.; Oudih, M. R.

    2008-01-01

    Expressions of the parallel and perpendicular temperature-dependent particle-number projected nuclear moment of inertia have been established by means of a discrete projection method. They generalize that of the FTBCS method and are well adapted to numerical computation. The effects of particle-number fluctuations have been numerically studied for some even-even actinide nuclei by using the single-particle energies and eigenstates of a deformed Woods-Saxon mean field. It has been shown that the parallel moment of inertia is practically not modified by the use of the projection method. In contrast, the discrepancy between the projected and FTBCS perpendicular moment of inertia values may reach 5%. Moreover, the particle-number fluctuation effects vary not only as a function of the temperature but also as a function of the deformation for a given temperature. This is not the case for the system energy

  14. 17 CFR 248.103-248.119 - [Reserved

    Science.gov (United States)

    2010-04-01

    ... 17 Commodity and Securities Exchanges 3 2010-04-01 2010-04-01 false [Reserved] 248.103-248.119 Section 248.103-248.119 Commodity and Securities Exchanges SECURITIES AND EXCHANGE COMMISSION (CONTINUED) REGULATIONS S-P AND S-AM Regulation S-AM: Limitations on Affiliate Marketing §§ 248.103-248.119 [Reserved] ...

  15. 46 CFR 119.435 - Integral fuel tanks.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 4 2010-10-01 2010-10-01 false Integral fuel tanks. 119.435 Section 119.435 Shipping... Machinery Requirements § 119.435 Integral fuel tanks. (a) Diesel fuel tanks may not be built integral with... for certification of a vessel, integral fuel tanks must withstand a hydrostatic pressure test of 35 k...

  16. Medical Isotopes Production Project: Molybdenum-99 and related isotopes: Environmental Impact Statement, Volume I

    International Nuclear Information System (INIS)

    1996-04-01

    This Environmental Impact Statement (EIS) provides environmental and technical information concerning the U.S. Department of Energy's (DOE) proposal to establish a domestic source to produce molybdenum-99 (Mo-99) and related medical isotopes (iodine-131, xenon-133 and iodine-125). Mo-99, a radioactive isotope of the element molybdenum, decays to form metastable technetium-99 (Tc-99m), a radioactive isotope used thousands of times daily in medical diagnostic procedures in the U.S. Currently, all Mo-99 used in the U.S. is obtained from a single Canadian source. DOE is pursuing the Medical Isotopes Production Project in order to ensure that a reliable supply of Mo-99 is available to the U.S. medical community. Under DOE's preferred alternative, the Chemistry and Metallurgy Research Facility at the Los Alamos National Laboratory (LANL) and the Annular Core Research Reactor and Hot Cell Facility at Sandia National Laboratories/New Mexico (SNL/NM) would be used for production of the medical isotopes. In addition to the preferred alternative, three other reasonable alternatives and a no action alternative are analyzed in detail. The sites for the three reasonable alternatives are LANL, Oak Ridge National Laboratory (ORNL), and Idaho National Engineering Laboratory (INEL). The analyses in this EIS indicate no significant difference in the potential environmental impacts among the alternatives. Each of the alternatives would use essentially the same technology for the production of the medical isotopes. Minor differences in environmental impacts among alternatives relate to the extent of activity necessary to modify and restart (as necessary) existing reactors and hot cell facilities at each of the sites, the quantities, of low-level radioactive waste generated, how such waste would be managed, and the length of time needed for initial and full production capacity

  17. Structure and biological activity of endogenous and synthetic agonists of GPR119

    Science.gov (United States)

    Tyurenkov, I. N.; Ozerov, A. A.; Kurkin, D. V.; Logvinova, E. O.; Bakulin, D. A.; Volotova, E. V.; Borodin, D. D.

    2018-02-01

    A G-protein-coupled receptor, GPR119, is a promising pharmacological target for a new class of hypoglycaemic drugs with an original mechanism of action, namely, increase in the glucose-dependent incretin and insulin secretion. In 2005, the first ligands were found and in the subsequent years, a large number of GPR119 agonists were synthesized in laboratories in various countries; the safest and most promising agonists have entered phase I and II clinical trials as agents for the treatment of type 2 diabetes mellitus and obesity. The review describes the major endogenous GPR119 agonists and the main trends in the design and modification of synthetic structures for increasing the hypoglycaemic activity. The data on synthetic agonists are arranged according to the type of the central core of the molecules. The bibliography includes 104 references.

  18. 7 CFR 57.119 - Political activity.

    Science.gov (United States)

    2010-01-01

    ... Political activity. Federal inspectors may participate in certain political activities, including management and participation in political campaigns as allowed by Federal regulation and AMS directives... 7 Agriculture 3 2010-01-01 2010-01-01 false Political activity. 57.119 Section 57.119 Agriculture...

  19. A Supply and Demand Update of the Molybdenum-99 Market

    International Nuclear Information System (INIS)

    2012-08-01

    Medical diagnostic imaging techniques using technetium-99m account for roughly 80% of all nuclear medicine procedures, representing over 30 million examinations worldwide every year. Disruptions in the supply chain of these medical isotopes - which have half-lives of 66 hours for molybdenum-99 ( 99 Mo) and 6 hours for its daughter isotope, technetium-99m (' 99m Tc), and thus must be produced continually - can lead to cancellations or delays in important medical testing services. Unfortunately, supply reliability has declined over the past decade due to unexpected or extended shutdowns at the few ageing 99 Mo-producing research reactor and processing facilities. These shutdowns have created global supply shortages. In 2011, the OECD Nuclear Energy Agency (NEA), along with its High-level Group on the Security of Supply of Medical Radioisotopes (HLG-MR), released a report that presents the reasons behind the lack of infrastructure that led to global supply shortages and a policy approach to encourage long-term medical isotope supply security. In that report, The Supply of Medical Radioisotopes: The Path to Reliability, the NEA also provides potential futures of supply and demand out to 2030. Since the release of The Path there have been a number of changes in the market and therefore this document provides an update on the 2011 supply and demand situation. This update is based on information provided to the NEA by members of the HLG-MR and other key stakeholders. This presentation of supply and demand future scenarios for the 99 Mo market revises previous NEA future scenarios based on new data and target conversion commitments from the supply chain. The update, unfortunately, does not present a more optimistic future scenario than previous presentations - the concern around the uneconomic situation of the supply chain continues to dominate the potential for new projects. This results in the potential for long-term shortages within the decade. However, there are a

  20. GPR119 as a fat sensor

    DEFF Research Database (Denmark)

    Hansen, Harald S; Rosenkilde, Mette M; Holst, Jens Juul

    2012-01-01

    acting through, for example, GPR40, but is also probably mediated in large part through the luminal formation of 2-monoacylglycerol acting on the 'fat sensor' GPR119. In the pancreas GPR119 may also be stimulated by 2-monoacylglycerol generated from local turnover of pancreatic triacylglycerol. Knowledge...

  1. 9 CFR 590.119 - Political activity.

    Science.gov (United States)

    2010-01-01

    ... 9 Animals and Animal Products 2 2010-01-01 2010-01-01 false Political activity. 590.119 Section 590.119 Animals and Animal Products FOOD SAFETY AND INSPECTION SERVICE, DEPARTMENT OF AGRICULTURE EGG... party or candidate, except as authorized by law or regulation of the Department, is prohibited. This...

  2. Uncoordinated (UNC)119: coordinating the trafficking of myristoylated proteins.

    Science.gov (United States)

    Constantine, Ryan; Zhang, Houbin; Gerstner, Cecilia D; Frederick, Jeanne M; Baehr, Wolfgang

    2012-12-15

    The mechanism by which myristoylated proteins are targeted to specific subcellular membrane compartments is poorly understood. Two novel acyl-binding proteins, UNC119A and UNC119B, have been shown recently to function as chaperones/co-factors in the transport of myristoylated G protein α-subunits and src-type tyrosine kinases. UNC119 polypeptides feature an immunoglobulin-like β-sandwich fold that forms a hydrophobic pocket capable of binding lauroyl (C12) and myristoyl (C14) side chains. UNC119A in rod photoreceptors facilitates the transfer of transducin α subunits (Tα) from inner segment to outer segment membranes by forming an intermediate diffusible UNC119-Tα complex. Similar complexes are formed in other sensory neurons, as the G proteins ODR-3 and GPA-13 in Caenorhabditis elegans unc-119 mutants traffic inappropriately. UNC119B knockdown in IMCD3 cells prevents trafficking ofmyristoylated nephrocystin-3 (NPHP3), a protein associated with nephronophthisis, to cilia. Further, UNC119A was shown to transport myristoylated src-type tyrosine kinases to cell membranes and to affect T-cell receptor (TCR) and interleukin-5 receptor (IL-5R) activities. These interactions establish UNC119 polypeptides as novel lipid-binding chaperones with specificity for a diverse subset of myristoylated proteins. Copyright © 2012 Elsevier Ltd. All rights reserved.

  3. 46 CFR 119.430 - Engine exhaust pipe installation.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 4 2010-10-01 2010-10-01 false Engine exhaust pipe installation. 119.430 Section 119... INSTALLATION Specific Machinery Requirements § 119.430 Engine exhaust pipe installation. (a) The design of all... an exhaust pipe. (b) Exhaust gas must not leak from the piping or any connections. The piping must be...

  4. 13 CFR 119.14 - Are there limitations regarding the use of program income?

    Science.gov (United States)

    2010-01-01

    ... ADMINISTRATION PROGRAM FOR INVESTMENT IN MICROENTREPRENEURS (âPRIMEâ OR âTHE ACTâ) § 119.14 Are there limitations... further PRIME program objectives. As such, fees collected from clients, and other program income as... reported on financial reports submitted to SBA and added to funds committed to the project by SBA and the...

  5. 32 CFR 701.119 - Privacy and the web.

    Science.gov (United States)

    2010-07-01

    ... 32 National Defense 5 2010-07-01 2010-07-01 false Privacy and the web. 701.119 Section 701.119... THE NAVY DOCUMENTS AFFECTING THE PUBLIC DON Privacy Program § 701.119 Privacy and the web. DON activities shall consult SECNAVINST 5720.47B for guidance on what may be posted on a Navy Web site. ...

  6. 14 CFR 119.9 - Use of business names.

    Science.gov (United States)

    2010-01-01

    ... 14 Aeronautics and Space 3 2010-01-01 2010-01-01 false Use of business names. 119.9 Section 119.9... COMMERCIAL OPERATORS General § 119.9 Use of business names. (a) A certificate holder under this part may not operate an aircraft under part 121 or part 135 of this chapter using a business name other than a business...

  7. Analyzing power and differential cross section at 9.9, 11.9 and 13.9 MeV for Ca(n,n)Ca

    International Nuclear Information System (INIS)

    Tornow, W.; Woye, E.; Mack, G.; Clegg, T.

    1982-01-01

    The analyzing power and differential cross section for elastic neutron scattering from calcium have been measured at 9.9, 11.9 and 13.9 MeV using the 2 H(d,n) 3 He source reaction and neutron time-of-flight (t.o.f.) techniques to detect the scattered neutrons. Polarized neutron beams were produced via the polarization transfer reaction 2 H(d vector,n vector) 3 He at THETA = 0 0 . The data have been corrected for finite geometry and multiple scattering effects. None of the global neutron-nucleus optical model parameter sets usually referred to in the literature reproduces the present cross-section and analyzing power data. Individual as well as energy-averaged fits of the data resulting from new optical model searches are presented. It is shown that the quoted uncertainties of a recent empirical determination of the real part ΔVsub(C) of the Coulomb correction term are probably underestimated. Our imaginary Coulomb correction term ΔWsub(C) agrees quite well with both a very recent empirical determination and theoretical studies. Although the quality of the fits to the data can be improved by adding iota-dependent potentials to the general optical potential, no definite conclusions can be drawn from the present data as to whether or not iota-dependent potentials are important in neutron-calcium scattering in the energy range investigated. The data have also been analyzed using a Fourier-Bessel series description of the real central optical potential. Comparing the chi 2 values, the experimental data are better reproduced by the Fourier-Bessel method than by our Woods-Saxon optical model analyses. The Fourier-Bessel potentials obtained show strong deviations from the standard Woods-Saxon shape but are in good agreement with calculations using the nuclear structure approach. (orig.)

  8. Evaluation of Some Dose Calibration for Measuring of 99mTc

    International Nuclear Information System (INIS)

    Nazaroh; Erni-Juita; Hermawan-Candra

    2001-01-01

    99m Tc is a prime radionuclide in nuclear medicine because of worthwhile in many diagnoses. According to ALARA concept, the lowest risk should be considered in the use of radioactive materials especially for health. Center for development of Radioisotopes and Radiopharmacy-BATAN, Serpong, serves several nuclear medicine departments supplying all their 99m Tc radiopharmaceuticals on a daily basis. It was observed that there was very poor consistency between the assays as determined by P3KRBin and those determined in the various nuclear medicine, using Dose-Calibrator. Investigation has been done to correct measurements result of 99m Tc using several Dose-Calibrators in some hospitals in Java island and the correction factors were vary from 0.91 to 1.16. The same survey done by researcher in Canada using a mock 99m Tc ( 57 Co) and 99m Tc and the correction factors were between 0.74 and 1. Investigation of influences of various environmental conditions on the Calibrator function was also carried out. Influences factors obtained from the survey were vary from 1 to 1.19. (author)

  9. 13 CFR 119.15 - If a grantee is unable to spend the entire amount allotted for a single fiscal year, can the...

    Science.gov (United States)

    2010-01-01

    ... 13 Business Credit and Assistance 1 2010-01-01 2010-01-01 false If a grantee is unable to spend...? 119.15 Section 119.15 Business Credit and Assistance SMALL BUSINESS ADMINISTRATION PROGRAM FOR... combination of both. (b) The request must be made no later than 60 days before the end of the budget/project...

  10. 38 CFR 4.119 - Schedule of ratings-endocrine system.

    Science.gov (United States)

    2010-07-01

    ... minute), eye involvement, muscular weakness, loss of weight, and sympathetic nervous system...-endocrine system. 4.119 Section 4.119 Pensions, Bonuses, and Veterans' Relief DEPARTMENT OF VETERANS AFFAIRS SCHEDULE FOR RATING DISABILITIES Disability Ratings The Endocrine System § 4.119 Schedule of ratings...

  11. 7 CFR 3550.119 - WWD eligibility requirements.

    Science.gov (United States)

    2010-01-01

    ....119 Agriculture Regulations of the Department of Agriculture (Continued) RURAL HOUSING SERVICE... 306C Water and Waste Disposal Grants § 3550.119 WWD eligibility requirements. In addition to the... residing in the household that is below the most recent poverty income guidelines established by the...

  12. 75 FR 53023 - Proposed Collection; Comment Request for Regulation Project

    Science.gov (United States)

    2010-08-30

    ... Reduction Act of 1995, Public Law 104-13 (44 U.S.C. 3506(c)(2)(A)). Currently, the IRS is soliciting comments concerning an existing final regulation, CO-99-91 (TD 8490), Limitations on Corporate Net...: Limitations on Corporate Net Operating Loss. OMB Number: 1545-1345. Regulation Project Number: CO-99-91...

  13. 18 CFR 401.119 - Disclosure to Congress.

    Science.gov (United States)

    2010-04-01

    ... 18 Conservation of Power and Water Resources 2 2010-04-01 2010-04-01 false Disclosure to Congress. 401.119 Section 401.119 Conservation of Power and Water Resources DELAWARE RIVER BASIN COMMISSION... Disclosure to Congress. All records of the Commission shall be disclosed to Congress upon an authorized...

  14. Preparation of a gel of zirconium molybdate for use in the generators of 99 Mo - 99m Tc prepared with 99 Mo produced by the 98 Mo(n,γ)99 Mo reaction

    International Nuclear Information System (INIS)

    Osso Junior, Joao A.; Lima, Ana Lucia V.P.; Silva, Nestor C. da; Nieto, Renata C.; Velosa, Adriana C. de

    1998-01-01

    IPEN develops a project concerning the preparation of a gel of Zirconium Molybdate for use in the generators of 99 Mo- 99m Tc . 99m Tc is the most used radioisotope in nuclear medicine diagnosis procedures and nowadays the generators are being prepared with imported 99 Mo, produced by 235 U fission. The production of 99 Mo by the 98 Mo(n, γ) 99 Mo reaction is now possible because of the power upgrade of IPEN's IEA-R1 reactor, from 2 to 5 MW. This work describes the preparation method of Zirconium Molybdate gel that will be used in the 99 Mo- 99m Tc generators. The gel is prepared by the chemical reaction between Mo, in Mo O 3 form, and Zr, in Zr O Cl 2 .8H 2 O form. After the reaction, the gel is filtered, dried and cracked with saline solution. The product is then loaded into glass columns for use as 99m Tc generator. The results showed the good quality of the gel prepared at laboratory level and of the generators evaluated. (author)

  15. 46 CFR 119.450 - Vent pipes for fuel tanks.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 4 2010-10-01 2010-10-01 false Vent pipes for fuel tanks. 119.450 Section 119.450... Specific Machinery Requirements § 119.450 Vent pipes for fuel tanks. (a) Each unpressurized fuel tank must... area of the vent pipe for diesel fuel tanks must be as follows: (1) Not less than the cross sectional...

  16. Lifetime measurements and the nonaxial deformation in 119I

    International Nuclear Information System (INIS)

    Srebrny, J.; Droste, Ch.; Morek, T.; Starosta, K.; Juutinen, S.; Piiparinen, M.

    2000-01-01

    Lifetimes of negative parity levels in four bands in 119 I were determined by RDM and DSAM. The 119 I nuclei were produced in the 109 Ag( 13 C,3n) reaction. Calculations in the frame of the CQPC model show that the model of γ-soft nucleus better describes 119 I than the γ-rigid one. (author)

  17. TIME-DEPENDENT MOSSBAUER-SPECTROSCOPY AND 119MTE-IMPLANTED GAAS

    NARCIS (Netherlands)

    MO, D; ZHANG, GL; NIESEN, L; Waard , de Hendrik

    1991-01-01

    A new type of time-dependent Mossbauer spectroscopy is proposed and realized on the basis of using the two-step decay (119m)Te --> 113Sb --> Sn-119. For the GaAs samples, implanted with a dose of 110-keV (119m)Te + 10(15) stable Te/cm2 and annealed at 600-degrees-C, the relative intensities of

  18. 47 CFR 69.119 - Basic service element expedited approval process.

    Science.gov (United States)

    2010-10-01

    ... 47 Telecommunication 3 2010-10-01 2010-10-01 false Basic service element expedited approval process. 69.119 Section 69.119 Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) COMMON CARRIER SERVICES (CONTINUED) ACCESS CHARGES Computation of Charges § 69.119 Basic service element...

  19. Geothermal environmental projects publication list with abstracts 1975-1978

    Energy Technology Data Exchange (ETDEWEB)

    Ricker, Y.E.; Anspaugh, L.R.

    1979-05-15

    This report contains 119 abstracts of publication resulting from or closely related to geothermal environmental projects conducted by the Environmental Sciences Division at Lawrence Livermore Laboratory. Publications are listed chronologically from 1975 through 1978. The main entries are numbered sequentially, and include the full citation, an abstract, and selected keywords. This section is followed by an author index, and a keyword index.

  20. 14 CFR 91.119 - Minimum safe altitudes: General.

    Science.gov (United States)

    2010-01-01

    ... than 500 feet to any person, vessel, vehicle, or structure. (d) Helicopters. Helicopters may be... 14 Aeronautics and Space 2 2010-01-01 2010-01-01 false Minimum safe altitudes: General. 91.119 Section 91.119 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF TRANSPORTATION...

  1. Development of fission Mo-99 production technology

    Energy Technology Data Exchange (ETDEWEB)

    Park, Jin Ho; Choung, W. M.; Lee, K. I. and others

    2001-05-01

    This R and D project is planed to supply domestic demands of Mo-99 through fission route, and consequently this project will be expected to rise up utilization of HANARO and KAERI's capability for marketing extension into domestic and oversea radiopharmaceutical market. HEU and LEU target types are decided and designed for fission Mo-99 production in domestic. Experimental study of target fabrication technology was performed and developed processing equipments. And conceptual design of target loading/unloading in/from HANARO device are performed. Tracer test of Mo-99 separation and purification process was performed, test results reach to Mo-99 recovery yield above 80% and decontamination factor above 1600. Combined Mo-99 separation and purification process was decided for hot test scheduled from next year, and performance test was performed. Conceptual design for modification of existing hot cell for fission Mo-99 production facility was performed and will be used for detail design. Assumption for the comparison of LEU and HEU target in fission Mo-99 production process were suggested and compared of merits and demerits in view of fabrication technology and economy feasibility.

  2. Development of fission Mo-99 production technology

    International Nuclear Information System (INIS)

    Park, Jin Ho; Choung, W. M.; Lee, K. I. and others

    2001-05-01

    This R and D project is planed to supply domestic demands of Mo-99 through fission route, and consequently this project will be expected to rise up utilization of HANARO and KAERI's capability for marketing extension into domestic and oversea radiopharmaceutical market. HEU and LEU target types are decided and designed for fission Mo-99 production in domestic. Experimental study of target fabrication technology was performed and developed processing equipments. And conceptual design of target loading/unloading in/from HANARO device are performed. Tracer test of Mo-99 separation and purification process was performed, test results reach to Mo-99 recovery yield above 80% and decontamination factor above 1600. Combined Mo-99 separation and purification process was decided for hot test scheduled from next year, and performance test was performed. Conceptual design for modification of existing hot cell for fission Mo-99 production facility was performed and will be used for detail design. Assumption for the comparison of LEU and HEU target in fission Mo-99 production process were suggested and compared of merits and demerits in view of fabrication technology and economy feasibility

  3. A proposal for spreading and commercializing the (n, gamma) 99Tc generator

    International Nuclear Information System (INIS)

    Yoshida, Kosuke; Hishinuma, Yukio; Tatenuma, Katsuyoshi

    2006-01-01

    A practicability of 99m Tc generator based on (n, gamma) method using PZC (Poly Zirconium Compound), a Mo adsorbent with a high adsorption efficiency, has been studied by the FNCA member countries as a part of the FNCA activities; three research collaboration projects, Technetium Generator Project (TCG), Neutron Activation Analysis Project (NAA) and Neutron Spreading Project (NS) have been set up in order to achieve the significant results of the research reactor use among Asian countries. As a result of the collaboration research, practical data on the 99m Tc elution and 99 Mo breakthrough has recently been obtained by using the new 99m Tc generator based on (n, gamma) method using PZC (indicate 'PZC- 99m Tc generator' as follows). Even though unexpected amount of 99 Mo breakthrough accompanied with the 99m Tc elution treatment were currently occurred, the problem has been solved by subsequently adding an alumina column underneath the generator column containing PZC. In accordance with the realization of the practical PZC- 99m Tc generator, an administering tests to the mice with labeled compound of 99m Tc generated by PZC method have already been started by BATAN, a loading machine to simplify the process of the 99 Mo adsorption to PZC and the 99 Mo-PZC packing to a generator column has been fabricated in BATAN's hot cell to realize a mass production of PZC- 99m Tc generator, and moreover the Japanese and Indonesian patents pertaining to the production process and the loading machine of PZC- 99m Tc generator have been applied with joint application of BATAN and KAKEN Co. By the current collaboration approaches mentioned above, it is clear that the Technetium Generator Project of FNCA is now reaching to a phase where the aims of the project shall be turned from establishment of the practical PZC- 99m C generator to establishment of the delivery system of PZC- 99m Tc generator to put them into commercial use. In this paper, a practical application of the PZC- 99m

  4. 99mTc-Tetrofosmin scintimammography in suspected breast cancer patients: comparison with 99mTc-MIBI

    International Nuclear Information System (INIS)

    Kim, Seong Jang; Kim, In Ju; Kim, Yong Ki; Bae, Young Tae

    2000-01-01

    The aim of this study was to investigate the diagnostic role of 99m Tc-Tetrofosmin in detection of breast cancer and compared with that of 99m Tc-MIBI. Forty-eight patients with a clinically palpable mass or abnormal mammographic or ultrasonographic findings had 99m Tc-MIBI and 99m Tc-Tetrofosmin scintimammographies after intravenous injection of 925 MBq of radiopharmaceuticals. The scintimammographs were correlated with histopathologic findings. Thirty-three patients were diagnosed with breast cancer and 15 patients with benign breast diseases. The numbers of true positive, true negative, false positive, and false negative cases of 99m Tc-MIBI scintimammography were 29, 10, 5, and 4 respectively. The sensitivity, specificity, positive predictive value, and negative predictive value of 99m Tc-MIBI scintimammographies were 87.8%, 66.7%, 85.3%, and 71.4% respectively. The numbers of true positive, true negative, false positive, and false negative cases of 99m Tc-Tetrofosmin were 31, 10, 5, and 2 respectively. The sensitivity, specificity, positive predictive value, negative predictive value of 99m Tc-Tetrofosmin were 93.9%, 66.7%, 86.1%, and 73.3% respectively. One patient was false negative in both 99m Tc-Tetrofosmin scintimammographies and its size was 0.5cm. 99m Tc-Tetrofosmin and 99m Tc-MIBI were non-invasive and useful in detection of breast cancer and 99m Tc-Tetrofosmin was comparable to the 99m Tc-MIBI in detection of primary breast cancer.=20

  5. Medical Isotopes Production Project: Molybdenum-99 and related isotopes - environmental impact statement. Volume II, comment response document

    International Nuclear Information System (INIS)

    1996-04-01

    This Environmental Impact Statement (EIS) provides environmental and technical information concerning the U.S. Department of Energy's (DOE) proposal to establish a domestic source to produce molybdenum-99 (Mo-99) and related isotopes (iodine-131, xenon-133, and iodine-125). Mo-99, a radioactive isotope of the element molybdenum, decays to form metastable technetium-99 (Tc-99m), a radioactive isotope used thousands of times daily in medical diagnostic procedures in the U.S. Currently, all Mo-99 used in the U.S. is obtained from a single Canadian source. DOE is pursuing the Medical Isotopes Production Project in order to ensure that a reliable supply of Mo-99 is available to the U.S. medical community as soon as practicable. Under DOE's preferred alternative, the Chemistry and Metallurgy Research Facility at the Los Alamos National Laboratory (LANL) and the Annular Core Research Reactor and Hot Cell Facility at Sandia National Laboratories/New Mexico (SNL/NM) would be used for production of the medical isotopes. In addition, three other reasonable alternatives and a No Action alternative are analyzed in detail, The sites for these three reasonable alternatives are LANL, Oak Ridge National Laboratory (ORNL), and Idaho National Engineering Laboratory (INEL). The analyses in this EIS indicate no significant difference in the potential environmental impacts among the alternatives. Each of the alternatives would use essentially the same technology for the production of the medical isotopes. Minor differences in environmental impacts among alternatives relate to the extent of activity necessary to modify and restart (as necessary) existing reactors and hot cell facilities at each of the sites, the quantities of low-level radioactive waste generated, how such waste would be managed, and the length of time needed for initial and full production capacity. This document contains comments recieved from meetings held regarding the site selection for isotope production

  6. 49 CFR 215.119 - Defective freight car truck.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 4 2010-10-01 2010-10-01 false Defective freight car truck. 215.119 Section 215... ADMINISTRATION, DEPARTMENT OF TRANSPORTATION RAILROAD FREIGHT CAR SAFETY STANDARDS Freight Car Components Suspension System § 215.119 Defective freight car truck. A railroad may not place or continue in service a...

  7. Development of kits for 99mTc radiopharmaceuticals for infection imaging. Report of a co-ordinated research project 2000-2003

    International Nuclear Information System (INIS)

    2004-09-01

    Infectious diseases remain a major health problem and cause of death worldwide, particularly in developing countries. Nuclear medicine imaging, because of its sensitivity, offers an attractive option for diagnosis of focal infections. This needs a reliable radiopharmaceutical that can selectively concentrate in sites of infection. Over the years 67 Ga and other radiopharmaceuticals that localize in inflammation associated with infection sites, also known as 'non-specific agents' have been used for infection imaging. However, experience has shown that an 'infection specific agent' that concentrates selectively at sites of infection and not inflammation would have several advantages. The first such agent developed more than two decades ago was 111 In-leucocytes which is still considered a 'gold standard'. Considerations of cost, availability, and superior properties for imaging make 99 mTc a better label than 111 In. 99 mTc white blood cell (WBC) was developed subsequently and used for infection imaging. However, both 111 In and 99 mTc WBCs have a number of drawbacks, in particular: each patient's blood sample has to be collected and individually radiolabelled; well-trained staff and suitable facilities for separating and labelling the patient's blood are needed; the risk of infection and cross-contamination associated with potential blood-borne microorganisms; and cost of materials. Because of these, considerable efforts have been continuously made towards developing convenient replacements for 99 mTc WBCs with limited success, 99 mTc antigranulocyte antibody being a good example. However, these radiopharmaceuticals still have many disadvantages, related to either their cost and availability or their performance. In view of the large potential for applications in patients, the development of new and improved 99 mTc labelled infection specific imaging agents was considered as a very worthwhile aim for scientific research in general and, in particular, for the

  8. 21 CFR 201.119 - In vitro diagnostic products.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 4 2010-04-01 2010-04-01 false In vitro diagnostic products. 201.119 Section 201...) DRUGS: GENERAL LABELING Exemptions From Adequate Directions for Use § 201.119 In vitro diagnostic products. (a) “In vitro diagnostic products” are those reagents, instruments and systems intended for use...

  9. Flight Determination of the Longitudinal Stability Characteristics of a 0.133-Scale Rocket-Powered Model of the Consolidated Vultee XFY-1 Airplane without Propellers at Mach Numbers from 0.73 to 1.19, TED No. NACA DE 369

    Science.gov (United States)

    Hastings, Earl E., Jr.; Mitcham, Grady L.

    1954-01-01

    A flight test has been conducted to determine the longitudinal stability and control,characteristics of a 0.133-scale model of the Consolidated Vultee XFY-1 airplane without propellers for the Mach number range between 0.73 and 1.19.

  10. 21 CFR 801.119 - In vitro diagnostic products.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false In vitro diagnostic products. 801.119 Section 801...) MEDICAL DEVICES LABELING Exemptions From Adequate Directions for Use § 801.119 In vitro diagnostic products. A product intended for use in the diagnosis of disease and which is an in vitro diagnostic...

  11. Effects of the particle-number projection on the isovector pairing energy

    International Nuclear Information System (INIS)

    Allal, N.H.; Fellah, M.; Oudih, M.R.; Benhamouda, N.

    2006-01-01

    The usual neutron-proton BCS wave function is simultaneously projected on both the good neutron and proton numbers using a discrete projection operator. The projected energy of the system is deduced as a limit of rapidly convergent sequence. It is numerically studied for the N=Z nuclei of which ''experimental'' pairing gaps may be deduced from the experimental odd-even mass differences. It then appears that the particle-number fluctuation effect is even more important than in the case of pairing between like-particles. (orig.)

  12. 32 CFR 536.119 - Scope for maritime claims.

    Science.gov (United States)

    2010-07-01

    ... 32 National Defense 3 2010-07-01 2010-07-01 true Scope for maritime claims. 536.119 Section 536... CLAIMS AGAINST THE UNITED STATES Maritime Claims § 536.119 Scope for maritime claims. The AMCSA applies...) Damage that is maritime in nature and caused by tortious conduct of U.S. military personnel or federal...

  13. 7 CFR 28.119 - Fee when request for classification is withdrawn.

    Science.gov (United States)

    2010-01-01

    ....119 Section 28.119 Agriculture Regulations of the Department of Agriculture AGRICULTURAL MARKETING SERVICE (Standards, Inspections, Marketing Practices), DEPARTMENT OF AGRICULTURE COMMODITY STANDARDS AND... Cotton Standards Act Fees and Costs § 28.119 Fee when request for classification is withdrawn. When the...

  14. 40 CFR 81.119 - Western Tennessee Intrastate Air Quality Control Region.

    Science.gov (United States)

    2010-07-01

    ... Quality Control Region. 81.119 Section 81.119 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY... Air Quality Control Regions § 81.119 Western Tennessee Intrastate Air Quality Control Region. The Western Tennessee Intrastate Air Quality Control Region consists of the territorial area encompassed by...

  15. 99mTc labelled peptides for imaging of peripheral receptors. Final report of a co-ordinated research project. 1995-1999

    International Nuclear Information System (INIS)

    2001-04-01

    99m Tc radiopharmaceuticals have remained the workhorse of diagnostic nuclear medicine over the last three decades ever since the introduction of the gamma camera as the main imaging instrument. Due to the near ideal nuclear properties such as gamma energy, half-life, lack of beta radiation and easy availability as a convenient generator system at an affordable cost of 99m Tc, it can be reasonably anticipated that 99m Tc will continue to retain this position in the foreseeable future. To a large extent this has been possible because of the successful development, over the years, of 99m Tc radiopharmaceuticals as substitutes for other clinically well established agents. Examples of these success stories are 99m Tc substitutes for 131 I hippuran and rose bengal 201 Tl and 123 I brain perfusion agents, which have come to be known collectively as 'second generation 99m Tc radiopharmaceuticals'. It should be acknowledged that each one of these developments was a result of innovative and sustained research and development efforts by scientists from different parts of the world. Concurrently these research efforts have made significant contributions to better understanding of the radiochemistry and co-ordination chemistry of 99m Tc. The radiopharmaceutical scientists are now in a much better position to design, prepare and evaluate 99m Tc complexes for specific applications. Building on this capability, the next step is development of 99m Tc substitutes for receptor specific radiopharmaceuticals, which have established clinical potential. Efforts in this direction are already ongoing and the work during the last decade on 99m Tc labelling of monoclonal antibodies can be considered the beginning of these 'third generation 99m Tc radiopharmaceuticals'. The International Atomic Energy Agency (IAEA) had organized two co-ordinated research projects (CRPs) in the past covering 99m Tc second generation agents and 99m Tc monoclonal antibodies, and the results were published in

  16. Comparison of relative renal function measured with either 99m Tc-DTPA or 99m Tc-EC dynamic scintigraphies with that measured with 99m Tc-DMSA static scintigraphy

    Energy Technology Data Exchange (ETDEWEB)

    Domingues, F.C.; Fujikawa, G.Y.; Decker, H.; Alonso, G.; Pereira, J.C.; Duarte, P.S. [Centro de Diagnostico Fleury, Sao Paulo, SP (Brazil). Secao de Medicina Nuclear; Sao Paulo Univ. (USP), SP (Brazil). Escola de Saude Publica. Dept. de Epidemiologia]. E-mail: paulo.duarte@fleury.com.br

    2006-07-15

    Objective: The aim of this study was to compare the renal function measured with either {sup 99m}Tc-DTPA or {sup 99m}Tc-EC dynamic scintigraphies with that measured using {sup 99m}Tc-DMSA static scintigraphy. Methods: the values of relative renal function measured in 111 renal dynamic scintigraphies performed either with {sup 99m}Tc-DTPA (55 studies) or with {sup 99m}Tc-EC (56 studies) were compared with the relative function measured using {sup 99m}Tc-DMSA static scintigraphy performed within a 1-month period. The comparisons were performed using Wilcoxon signed rank test. The number of {sup 99m}Tc-DTPA and {sup 99m}Tc-EC studies that presented relative renal function different by more than 5% from that measured with {sup 99m}Tc-DMSA, using chi square test were also compared. Results: the relative renal function measured with {sup 99m}Tc-EC is not statistically different from that measured with {sup 99m}Tc-DMSA (p = 0.97). The relative renal function measured with {sup 99m}Tc-DTPA was statistically different from that measured using {sup 99m}Tc-DMSA, but with a borderline statistical significance (p = 0.05). The number of studies with relative renal function different by more than 5% from that measured with {sup 99m}Tc-DMSA is higher for the {sup 99m}Tc-DTPA scintigraphy (p 0.04) than for {sup 99m}Tc-EC. Conclusion: the relative renal function measured with {sup 99m}Tc-EC dynamic scintigraphy is comparable with that measured with {sup 99m}Tc-DMSA static scintigraphy, while the relative renal function measured with {sup 99m}Tc-DTPA dynamic scintigraphy presents a significant statistical difference from that measured with {sup 99m}Tc-DMSA static scintigraphy. (author)

  17. Comparison of relative renal function measured with either 99m Tc-DTPA or 99m Tc-EC dynamic scintigraphies with that measured with 99m Tc-DMSA static scintigraphy

    International Nuclear Information System (INIS)

    Domingues, F.C.; Fujikawa, G.Y.; Decker, H.; Alonso, G.; Pereira, J.C.; Duarte, P.S.; Sao Paulo Univ.

    2006-01-01

    Objective: The aim of this study was to compare the renal function measured with either 99m Tc-DTPA or 99m Tc-EC dynamic scintigraphies with that measured using 99m Tc-DMSA static scintigraphy. Methods: the values of relative renal function measured in 111 renal dynamic scintigraphies performed either with 99m Tc-DTPA (55 studies) or with 99m Tc-EC (56 studies) were compared with the relative function measured using 99m Tc-DMSA static scintigraphy performed within a 1-month period. The comparisons were performed using Wilcoxon signed rank test. The number of 99m Tc-DTPA and 99m Tc-EC studies that presented relative renal function different by more than 5% from that measured with 99m Tc-DMSA, using chi square test were also compared. Results: the relative renal function measured with 99m Tc-EC is not statistically different from that measured with 99m Tc-DMSA (p = 0.97). The relative renal function measured with 99m Tc-DTPA was statistically different from that measured using 99m Tc-DMSA, but with a borderline statistical significance (p = 0.05). The number of studies with relative renal function different by more than 5% from that measured with 99m Tc-DMSA is higher for the 99m Tc-DTPA scintigraphy (p 0.04) than for 99m Tc-EC. Conclusion: the relative renal function measured with 99m Tc-EC dynamic scintigraphy is comparable with that measured with 99m Tc-DMSA static scintigraphy, while the relative renal function measured with 99m Tc-DTPA dynamic scintigraphy presents a significant statistical difference from that measured with 99m Tc-DMSA static scintigraphy. (author)

  18. 7 CFR 1221.119 - Refunds.

    Science.gov (United States)

    2010-01-01

    ... Regulations of the Department of Agriculture (Continued) AGRICULTURAL MARKETING SERVICE (MARKETING AGREEMENTS... INFORMATION ORDER Sorghum Promotion, Research, and Information Order Sorghum Promotion, Research, and Information Board § 1221.119 Refunds. Any producer or importer from whom an assessment is collected and...

  19. 37 CFR 11.9 - Limited recognition in patent matters.

    Science.gov (United States)

    2010-07-01

    ... 37 Patents, Trademarks, and Copyrights 1 2010-07-01 2010-07-01 false Limited recognition in patent matters. 11.9 Section 11.9 Patents, Trademarks, and Copyrights UNITED STATES PATENT AND TRADEMARK OFFICE, DEPARTMENT OF COMMERCE REPRESENTATION OF OTHERS BEFORE THE UNITED STATES PATENT AND TRADEMARK OFFICE...

  20. Moessbauer study of supertransferred hyperfine field of /sup 119/Sn (Sn/sup 4 +/) in Casub(1-x)Srsub(x)MnO/sub 3/

    Energy Technology Data Exchange (ETDEWEB)

    Takano, M [Konan Univ., Kobe (Japan). Faculty of Science; Takeda, Y; Shimada, M; Matsuzawa, T; Shinjo, T

    1975-09-01

    Casub(1-x)Srsub(x)Mnsub(0.99)Snsub(0.01)O/sub 3/(0<=x<=1) with (nearly) cubic perovskite structures were prepared and the magnetic hyperfine fields of /sup 119/Sn (Sn/sup 4 +/) were measured by the Moessbauer effect. The hyperfine fields arise from unpaired s electron spin densities transferred from Mn/sup 4 +/ ions (supertransferred hyperfine interaction). The hyperfine field for a tin ion was found to depend linearly upon the numbers of Ca/sup 2 +/ and Sr/sup 2 +/ ions in the neighboring divalent cation sites, with proportional coefficients having opposite signs. To explain experimental results two kinds of spin transfer processes contributing to the hyperfine field oppositely to each other have been considered, and spin transfer via a divalent cation is emphasized particularly. The hyperfine field at 0 K for Sn/sup 4 +/ in CaMnO/sub 3/ is -75 kOe, while +20 kOe for Sn/sup 4 +/ in SrMnO/sub 3/.

  1. AMORE Mo-99 Spike Test Results

    Energy Technology Data Exchange (ETDEWEB)

    Youker, Amanda J. [Argonne National Lab. (ANL), Argonne, IL (United States); Krebs, John F. [Argonne National Lab. (ANL), Argonne, IL (United States); Quigley, Kevin J. [Argonne National Lab. (ANL), Argonne, IL (United States); Byrnes, James P. [Argonne National Lab. (ANL), Argonne, IL (United States); Rotsch, David A [Argonne National Lab. (ANL), Argonne, IL (United States); Brossard, Thomas [Argonne National Lab. (ANL), Argonne, IL (United States); Wesolowski, Kenneth [Argonne National Lab. (ANL), Argonne, IL (United States); Alford, Kurt [Argonne National Lab. (ANL), Argonne, IL (United States); Chemerisov, Sergey [Argonne National Lab. (ANL), Argonne, IL (United States); Vandegrift, George F. [Argonne National Lab. (ANL), Argonne, IL (United States)

    2017-09-27

    With funding from the National Nuclear Security Administrations Material Management and Minimization Office, Argonne National Laboratory (Argonne) is providing technical assistance to help accelerate the U.S. production of Mo-99 using a non-highly enriched uranium (non-HEU) source. A potential Mo-99 production pathway is by accelerator-initiated fissioning in a subcritical uranyl sulfate solution containing low enriched uranium (LEU). As part of the Argonne development effort, we are undertaking the AMORE (Argonne Molybdenum Research Experiment) project, which is essentially a pilot facility for all phases of Mo-99 production, recovery, and purification. Production of Mo-99 and other fission products in the subcritical target solution is initiated by putting an electron beam on a depleted uranium (DU) target; the fast neutrons produced in the DU target are thermalized and lead to fissioning of U-235. At the end of irradiation, Mo is recovered from the target solution and separated from uranium and most of the fission products by using a titania column. The Mo is stripped from the column with an alkaline solution. After acidification of the Mo product solution from the recovery column, the Mo is concentrated (and further purified) in a second titania column. The strip solution from the concentration column is then purified with the LEU Modified Cintichem process. A full description of the process can be found elsewhere [1–3]. The initial commissioning steps for the AMORE project include performing a Mo-99 spike test with pH 1 sulfuric acid in the target vessel without a beam on the target to demonstrate the initial Mo separation-and-recovery process, followed by the concentration column process. All glovebox operations were tested with cold solutions prior to performing the Mo-99 spike tests. Two Mo-99 spike tests with pH 1 sulfuric acid have been performed to date. Figure 1 shows the flow diagram for the remotely operated Mo-recovery system for the AMORE project

  2. Effect of number of of projections on inverse radon transform based image reconstruction by using filtered back-projection for parallel beam transmission tomography

    International Nuclear Information System (INIS)

    Qureshi, S.A.; Mirza, S.M.; Arif, M.

    2007-01-01

    This paper present the effect of number of projections on inverse Radon transform (IRT) estimation using filtered back-projection (FBP) technique for parallel beam transmission tomography. The head phantom and the lung phantom have been used in this work. Various filters used in this study include Ram-Lak, Shepp-Logan, Cosin, Hamming and Hanning filters. The slices have been reconstructed by increasing the number of projections through parallel beam transmission tomography keeping the projections uniformly distributed. The Euclidean and Mean Squared errors and peak signal-to-noise ratio (PSNR) have been analyzed for their sensitiveness as functions of number of projections. It has found that image quality improves with the number of projections but at the cost of the computer time. The error has been minimized to get the best approximation of inverse Radon transform (IRT) as the number of projections is enhanced. The value of PSNR has been found to increase from 8.20 to 24.53 dB as the number of projections is raised from 5 to 180 for head phantom. (author)

  3. Solving for the particle-number-projected HFB wavefunction

    International Nuclear Information System (INIS)

    Jia, L.Y.

    2015-01-01

    Recently we proposed a particle-number-conserving theory for nuclear pairing (Jia, 2013) [19] through the generalized density matrix formalism. The relevant equations were solved for the case when each single-particle level has a distinct set of quantum numbers and could only pair with its time-reversed partner (BCS-type Hamiltonian). In this work we consider the more general situation when several single-particle levels could have the same set of quantum numbers and pairing among these levels is allowed (HFB-type Hamiltonian). The pair condensate wavefunction (the HFB wavefunction projected onto good particle number) is determined by the equations of motion for density matrix operators instead of the variation principle. The theory is tested in the simple two-level model with factorizable pairing interactions, and semi-realistic models with the zero-range delta interaction and the realistic Bonn-CD interaction

  4. 19 CFR 11.9 - Special marking on certain articles.

    Science.gov (United States)

    2010-04-01

    ... 19 Customs Duties 1 2010-04-01 2010-04-01 false Special marking on certain articles. 11.9 Section... OF THE TREASURY PACKING AND STAMPING; MARKING Marking § 11.9 Special marking on certain articles. (a... of additional U.S. Note 4, Chapter 91. If any article so required to be marked is found not to be...

  5. Lifetime measurements and the nonaxial deformation in 119I

    International Nuclear Information System (INIS)

    Srebrny, J.; Droste, Ch.; Morek, T.; Starosta, K.; Juutinen, S.; Piiparinen, M.; Toermaenen, S.; Virtanen, A.

    2000-01-01

    Complete text of publication follows. Lifetimes in four negative parity bands of 119 I were measured using DSAM and RDM. 119 I nuclei were produced in the 109 Ag( 13 C,3n) reaction, γγ coincidences were collected using the NORDBALL array. The detailed description of experiment is given in (1,2,3). Information about electromagnetic properties of four negative parity bands, originating from the h 11/2 quasiproton coupled to an axially asymmetric core, was obtained. The lifetimes of 31 negative parity levels were determined. That is one of the largest sets of electromagnetic transition probabilities for an odd - A nucleus from the 50 119 I nucleus. We see that the 53-rd proton added to the 118 Te nucleus, through the polarisation effect, changes the properties of the even-even core. The β-deformation becomes at least as large as that of 120 Xe (β ∼ 0.28), whereas the γ-deformation is around 30 deg. Comparison of experimental data with calculation within Core Quasiparticle Coupling Model indicates the advantage of the γ- soft model over the γ-rigid one in the description of h 11/2 band structure in 119 I. One can see, that the most valuable information concerning the shape of 119 I is based on the properties of the unfavoured states, especially those belonging to band 9, with their regular energy spacing and fast intraband transitions. (author)

  6. Moderation of the 119mSn isomer radioactive decay

    International Nuclear Information System (INIS)

    Godovikov, S.K.

    1999-01-01

    The evaluation of the constant of the braked 119m Sn nuclei decay in the Moessbauer source, being for a long time in contact with a resonance shield, is carried out. The high stability of these nuclei relative to decay is established. The 119m Sn subjected to prolonged impact of the standing electromagnetic wave field become resistant to radioactive decay [ru

  7. 14 CFR 119.65 - Management personnel required for operations conducted under part 121 of this chapter.

    Science.gov (United States)

    2010-01-01

    ... or Part 135 of This Chapter § 119.65 Management personnel required for operations conducted under... of management personnel due to— (1) The kind of operation involved; (2) The number and type of... 14 Aeronautics and Space 3 2010-01-01 2010-01-01 false Management personnel required for...

  8. 14 CFR 119.69 - Management personnel required for operations conducted under part 135 of this chapter.

    Science.gov (United States)

    2010-01-01

    ... or Part 135 of This Chapter § 119.69 Management personnel required for operations conducted under... of management personnel due to— (1) The kind of operation involved; (2) The number and type of... 14 Aeronautics and Space 3 2010-01-01 2010-01-01 false Management personnel required for...

  9. The risk analysis used to manufacture 99Mo/99mTc generators

    International Nuclear Information System (INIS)

    Fano Machín, Yoiz; Alberti Ramírez, Alejandro; Gamboa Marrero, Regla; Suárez Beyríes, Karina; Cruz Morales, Amed

    2016-01-01

    In this work the steps to be followed for the risk analysis in the process of production of 99 Mo / 99m Tc generators in CENTIS, using the methodology of analysis of modes and effects of failures are collected. The analysis of the type and probability of occurrence of the failures in the process, as well as the impact on the quality of the same and the probability of detection of such failures, were used for the use of techniques used in quality assurance such as: storm Ideas and cause-effect diagram. Scales were established for the determination of severity, probability of occurrence, probability of detection and calculation of the number of risk probabilities. The guidelines were laid down for the future application of this technique, which will establish a decision-making process regarding the risks associated with the production process of 99 Mo / 99m Tc generators. (author)

  10. Renal function assessed by 99mTc-DMSA scintigraphy before and after percutaneous nephrostolithotripsy (PNL)

    International Nuclear Information System (INIS)

    Sakurai, Masaki; Hioki, Takuichi; Kitano, Tokio; Nakagawa, Tsuyoshi; Yamaguchi, Nobuo; Kawamura, Juichi

    1988-01-01

    99m Tc-DMSA scintigraphy was carried out in 43 patients with unilateral renal stones before and after PNL. This study was repeated about one year after PNL in 12 patients. DMSA renal uptake was calculated two hours after injection of 99m Tc-DMSA. The study was performed using the dual type gamma camera. The renal function was assessed by the formula : 99m Tc-DMSA renal uptake of the operated side/ 99m Tc-DMSA renal uptake of the contralateral side. The change (ratio before/after PNL) x 100 was regarded as the percent change of renal function. Local abnormalities in the 99m Tc-DMSA renal scintigram after PNL were observed in 15 patients. The renal function decreased significantly to 95.8 ± 8.7 % from the base line 4 - 8 weeks after PNL. The renal function improved significantly to 98.6 ± 14.7 % from 92.1 ± 11.9 % in 12 patients about one year after PNL. It is concluded that although the renal function slightly decreased 4 - 8 weeks after PNL, it is expected to improve within 1 year after PNL. 99M Tc-DMSA scintigraphy is a useful adjunct to evaluate the renal function before and after PNL. (author)

  11. 29 CFR 99.315 - Audit findings follow-up.

    Science.gov (United States)

    2010-07-01

    ... 29 Labor 1 2010-07-01 2010-07-01 true Audit findings follow-up. 99.315 Section 99.315 Labor Office... § 99.315 Audit findings follow-up. (a) General. The auditee is responsible for follow-up and corrective... include the reference numbers the auditor assigns to audit findings under § 99.510(c). Since the summary...

  12. Calibration of Sn-119 isomer shift using ab initio wave function methods

    NARCIS (Netherlands)

    Kurian, Reshmi; Filatov, Michael

    2009-01-01

    The isomer shift for the 23.87 keV M1 resonant transition in the Sn-119 nucleus is calibrated with the help of ab initio calculations. The calibration constant alpha(Sn-119) obtained from Hartree-Fock (HF) calculations (alpha(HF)(Sn-119)=(0.081 +/- 0.002)a(0)(-3) mm/s) and from second-order

  13. In vitro and in vivo comparison of binding of 99m-Tc-labeled anti-CEA MAb F33-104 with 99m-Tc-labeled anti-CEA MAb BW431/26

    International Nuclear Information System (INIS)

    Watanabe, N.; Gunma Univ. School of Medicine; Oriuchi, N.; Inoue, T.; Sugiyama, S.; Kuroki, M.; Matsuoka, Y.; Tanada, S.; Murata, H.; Sasaki, Y.

    1999-01-01

    Aim: The purpose of this study was to assess the potential for radioimmunodetection (RAID) of murine anti-carcinoembryonic antigen (CEA) monoclonal antibody (MAb) F33-104 labeled with technetium-99m (99m-Tc) by a reduction-mediated labeling method. Methods: The binding capacity of 99m-Tc-labeled anti-CEA MAb F33-104 with CEA by means of in vitro procedures such as immunoradiometric assay and cell binding assay and the biodistribution of 99m-Tc-labeled anti-CEA MAb F33-104 in normal nude mice and nude mice bearing human colon adenocarcinoma LS180 tumor were investigated and compared with 99m-Tc-labeled anti-CEA MAb BW431/26. Results: The in vitro binding rate of 99m-Tc-labeled anti-CEA MAb F33-104 with CEA in solution and attached to the cell membrane was significantly higher than 99m-Tc-labeled anti-CEA MAb BW431/261 (31.4 ± 0.95% vs. 11.9 ± 0.55% at 100 ng/mL of soluble CEA, 83.5 ± 2.84% vs. 54.0 ± 2.54% at 10 7 of LS 180 cells). In vivo, accumulation of 99m-Tc-labeled anti-CEA MAb F33-104 was higher at 18 h postinjection than 99m-Tc-labeled anti-CEA MAb BW431/26 (20.1 ± 3.50% ID/g vs. 14.4 ± 3.30% ID/g). 99m-Tc-activity in the kidneys of nude mice bearing tumor was higher at 18 h postinjection than at 3 h (12.8 ± 2.10% ID/g vs. 8.01 ± 2.40% ID/g of 99m-Tc-labeled anti-CEA MAb F33-104, 10.7 ± 1.70% ID/g vs. 8.10 ± 1.75% ID/g of 99m-Tc-labeled anti-CEA MAb BW431/26). Conclusion: 99m-Tc-labeled anti-CEA MAb F33-104 is a potential novel agent for RAID of recurrent colorectal cancer. (orig.) [de

  14. Measurement of formation cross-section of 99Mo from the 98Mo(n,γ) and 100Mo(n,2n) reactions.

    Science.gov (United States)

    Badwar, Sylvia; Ghosh, Reetuparna; Lawriniang, Bioletty M; Vansola, Vibha; Sheela, Y S; Naik, Haladhara; Naik, Yeshwant; Suryanarayana, Saraswatula V; Jyrwa, Betylda; Ganesan, Srinivasan

    2017-11-01

    The formation cross-section of medical isotope 99 Mo from the 98 Mo(n,γ) reaction at the neutron energy of 0.025eV and from the 100 Mo(n,2n) reaction at the neutron energies of 11.9 and 15.75MeV have been determined by using activation and off-line γ-ray spectrometric technique. The thermal neutron energy of 0.025eV was used from the reactor critical facility at BARC, Mumbai, whereas the average neutron energies of 11.9 and 15.75MeV were generated using 7 Li(p,n) reaction in the Pelletron facility at TIFR, Mumbai. The experimentally determined cross-sections were compared with the evaluated nuclear data libraries of ENDF/B-VII.1, CENDL-3.1, JENDL-4.0 and JEFF-3.2 and are found to be in close agreement. The 100 Mo(n,2n) 99 Mo reaction cross-sections were also calculated theoretically by using TALYS-1.8 and EMPIRE-3.2 computer codes and compared with the experimental data. Copyright © 2017 Elsevier Ltd. All rights reserved.

  15. A draft business plan for the production of PZC 99Mo-99mTc generator in the Philippines

    International Nuclear Information System (INIS)

    Sombrito, Elvira Z.; Cabalfin, Estelita G.; Calix, Virginia S.; Dela Rosa, Alumanda M.; Borras, Ma. Teresa L.; Bulos, Adelina dM.

    2007-01-01

    Technetium-99m ( 99m Tc) remains as the main workhorse of nuclear medicine in the country. Alone or conjugated with other ligands, it is being used to show the function of major organs and other tissues such as the lung, brain, kidney, liver and bone. It is imported to the country as 99 Mo- 99m Tc generator. These commercial generators use fission molybdenum adsorbed onto alumina column. The FNCA project has shown the feasibility of using a PZC column-reactor 99 Mo generator for commercial applications, citing mainly the cheaper cost of the PZC generator than the imported alumina column-fission 99 Mo generator. PNRI proposes in this draft business plan, the commercial production of PZC generator through the establishment of a facility for the in-house production of 99 Mo- 99m Tc generator. The generator will use PZC coming from Japan as the column material, 99 Mo sourced from neighboring countries and an automatic loading and adsorption machine. Because the PNRI has no local production of the generator, the requirements for successfully venturing into this business activity may differ from the other FNCA members. A careful assessment based on verified data will be needed to refine the business plan. (author)

  16. The trend of 99mTc generator in FNCA countries

    International Nuclear Information System (INIS)

    Genka, Tsuguo; Machi, Sueo

    2004-01-01

    In the 2001 Workshop on Utilization of Research Reactors held in Beijing, eight delegates from the FNCA countries, namely China, Indonesia, Japan, Korea, Malaysia, the Philippines, Thailand and Vietnam, for the 99m Tc Generator Project, presented papers or orally pleaded the current status of utilization and production in terms of 99 Mo solution, 99 Mo/ 99m Tc generator or extracted 99m Tc solution in each country. This paper is a brief compilation of these topics and some additional information obtained afterward the workshop. (author)

  17. Transition probabilities in negative parity bands of the 119I nucleus

    International Nuclear Information System (INIS)

    Srebrny, J.; Droste, Ch.; Morek, T.; Starosta, K.; Wasilewski, A.A.; Pasternak, A.A.; Podsvirova, E.O.; Lobach, Yu.N.; Hagemann, G.H.; Juutinen, S.; Piiparinen, M.; Toermaenen, S.; Virtanen, A.

    2001-01-01

    Lifetimes in four negative-parity bands of 119 I were measured using DSAM and RDM. 119 I nuclei were produced in the 109 Ag( 13 C,3n) reaction, γγ coincidences were collected using the NORDBALL array. RDDSA - a new method of RDM analysis - is described. This method allowed for the self-calibration of stopping power. From 31 measured lifetimes, 39 values of B(E2) were established. Calculations in the frame of the Core Quasi Particle Coupling (CQPC) model were focused on the problem of susceptibility of the nucleus to γ-deformation. It was established that nonaxial quadrupole deformation of 119 I plays on important role. The Wilets-Jean model of a γ-soft nucleus describes the 119 I nucleus in a more consistent way then the Davydov-Filippov model of a γ-rigid nucleus

  18. Tc-99m-labeled red blood cells for the measurement of red cell mass in newborn infants: concise communication

    International Nuclear Information System (INIS)

    Linderkamp, O.; Betke, K.; Fendel, H.; Klemm, J.; Lorenzen, K.; Riegel, K.P.

    1980-01-01

    In vitro and in vivo investigations were performed to examine the binding of Tc-99m to neonatal red blood cells (RBC). Labeling efficiency was about 90%, and unbound Tc-99m less than 3% after one washing, in premature and full-term newborns and in children. Thus presence of high percentages of fetal hemoglobin (Hb F) did not influence the labeling of RBCs with Tc-99m. RBCs of 11 newborns were hemolysed and the distribution of Tc-99m on RBC components was analyzed. Although Hb F percentage averaged (60.0 +- 8.10)% (s.d.), only (11.9 +- 3.7)% of Tc-99m was bound by Hb F, whereas (45.0 +- 6.1)% was associated with Hb A. RBC membranes bound (13.7 +- 4.3)% and (29.3 +- 4.0)% were found unbound in hemolysates. These results indicate that Tc-99m preferentially binds to beta chains. In vivo equilibration of Tc-99m RBCs and of albumin labeled with Evans blue was investigated in five newborn infants. Tc-99m RBCs were stable in each case during the first hour after injection. Elution of Tc-99m from RBCs was (3.4 +- 1.5)% per h. Body-to-venous hematocrit ratio averaged 0.86 +- 0.03

  19. Wave number determination of Pc 1–2 mantle waves considering He++ ions: A Cluster study

    Czech Academy of Sciences Publication Activity Database

    Grison, Benjamin; Escoubet, C. P.; Santolík, Ondřej; Cornilleau-Wehrlin, N.; Khotyaintsev, Y.

    2014-01-01

    Roč. 119, č. 9 (2014), s. 7601-7614 ISSN 2169-9380 R&D Projects: GA MŠk 7E12026; GA ČR(CZ) GPP209/11/P848; GA MŠk LH12231 Institutional support: RVO:68378289 Keywords : EMIC * refractive index * wave number * k-filtering * Pc 1–2 mantle wave * distant cusp Subject RIV: BL - Plasma and Gas Discharge Physics Impact factor: 3.426, year: 2014 http://onlinelibrary.wiley.com/doi/10.1002/2013JA019719/abstract

  20. 75 FR 33671 - Proposed Collection; Comment Request for Regulation Project

    Science.gov (United States)

    2010-06-14

    ... Reduction Act of 1995, Public Law 104-13 (44 U.S.C. 3506(c)(2)(A)). Currently, the IRS is soliciting comments concerning an existing final regulation, REG-106917-99 (TD 8996), Changes in Accounting Periods... INFORMATION: Title: Changes in Accounting Periods. OMB Number: 1545-1748. Regulation Project Number: REG...

  1. Dose calibrator linearity test: {sup 99m}Tc versus {sup 18}F radioisotopes

    Energy Technology Data Exchange (ETDEWEB)

    Willegaignon, Jose; Coura-Filho, George Barberio; Garcez, Alexandre Teles, E-mail: willegaignon@hotmail.com [Instituto do Cancer do Estado de Sao Paulo Octavio Frias de Oliveira (ICESP), Sao Paulo, SP (Brazil); Sapienza, Marcelo Tatit; Buchpiguel, Carlos Alberto [Universidade de Sao Paulo (FM/USP), Sao Paulo, SP (Brazil). Fac. de Medicina; Alves, Carlos Eduardo Gonzalez Ribeiro; Cardona, Marissa Anabel Rivera; Gutterres, Ricardo Fraga [Comissao Nacional de Energia Nuclear (CNEN), Rio de Janeiro, RJ (Brazil)

    2015-01-15

    Objective: the present study was aimed at evaluating the viability of replacing {sup 18}F with {sup 99m}Tc in dose calibrator linearity testing. Materials and methods: the test was performed with sources of {sup 99m}Tc (62 GBq) and {sup 18}F (12 GBq) whose activities were measured up to values lower than 1 MBq. Ratios and deviations between experimental and theoretical {sup 99m}Tc and {sup 18}F sources activities were calculated and subsequently compared. Results: mean deviations between experimental and theoretical {sup 99m}Tc and {sup 18}F sources activities were 0.56 (± 1.79)% and 0.92 (± 1.19)%, respectively. The mean ratio between activities indicated by the device for the {sup 99m}Tc source as measured with the equipment precalibrated to measure {sup 99m}Tc and {sup 18}F was 3.42 (± 0.06), and for the {sup 18}F source this ratio was 3.39 (± 0.05), values considered constant over the measurement time. Conclusion: the results of the linearity test using {sup 99m}Tc were compatible with those obtained with the {sup 18}F source, indicating the viability of utilizing both radioisotopes in dose calibrator linearity testing. Such information in association with the high potential of radiation exposure and costs involved in {sup 18}F acquisition suggest {sup 99m}Tc as the element of choice to perform dose calibrator linearity tests in centers that use {sup 18}F, without any detriment to the procedure as well as to the quality of the nuclear medicine service. (author)

  2. 76 FR 1664 - Notice of Final Federal Agency Actions on State Highway 99 (Segment G)

    Science.gov (United States)

    2011-01-11

    ... on State Highway 99 (Segment G) AGENCY: Federal Highway Administration (FHWA), DOT. ACTION: Notice of.... 139(l)(1). The actions relate to a proposed highway project, Grand Parkway (State Highway 99) Segment... (State Highway 99) Segment G from I- 45 to US 59 in Harris and Montgomery Counties; FHWA Project...

  3. Under used technetium-99m generators

    International Nuclear Information System (INIS)

    Mushtaq, A.

    2001-01-01

    Health care reform truly has become a global issue and it will undoubtedly have a dramatic impact on the future of nuclear medicine business in particular. A bigger concern within the nuclear medicine community is its competitiveness with other modalities and cost effectiveness.Technetium-99m and its generators are playing key role for the majority of diagnostic scans performed in the world today. Availability of ''9''9''mTc can be increased if it is separated from ''9''9Mo after much shorter growth times. After proper planning with the extra ''9''9''mTc, a significant number of scans can be performed or we would be able to order approximately 30% low activity ''9''9Tc generators to fulfill our requirements

  4. 29 CFR 794.119 - Dependence of exemption on sales volume of the enterprise.

    Science.gov (United States)

    2010-07-01

    ... 29 Labor 3 2010-07-01 2010-07-01 false Dependence of exemption on sales volume of the enterprise. 794.119 Section 794.119 Labor Regulations Relating to Labor (Continued) WAGE AND HOUR DIVISION... Act Annual Gross Volume of Sales § 794.119 Dependence of exemption on sales volume of the enterprise...

  5. S Tank Farm SL-119 saltwell piping failure analysis report

    International Nuclear Information System (INIS)

    Carlos, W.C.

    1994-01-01

    On January 24, 1992, while pressure testing saltwell line SL-119 in the 241-S Tank Farm, water was observed spraying out of heat trace enclosure. The SL-115, SL-116, SN-215, and SN-216 saltwell lines also recently failed pressure testing because of leaks. This study documents the pertinent facts about the SL-119 line and discusses the cause of the failures. The inspection of the SL-119 failure revealed two through-the-wall holes in the top center of the pipeline. The inspection also strongly suggests that the heat tracing system is directly responsible for causing the SL-119 failure. Poor design of the heat tracing system allowed water to enter, condense, and collect in the electric metallic tubing (EMT) carbon steel conduits. Water flowed to the bottom of the elbow of the conduit and corroded out the elbow. The design also allowed drifting desert sand to enter into the conduit and fall to the bottom (elbow) of the conduit. The sand became wet and aided in the corrosion of the elbow of the conduit. After the EMT conduits corroded though, the water dripped from the corroded ends of the EMT conduits onto the top of the saltwell pipe, corroding the two holes into the top of the line. If the heat tracing hot splice box had not allowed moisture to enter the EMT conduits, the saltwell piping would not have corroded and caused SL-119 to fail

  6. Production and availability of 99mTc generators and of 99Mo: technology considerations and the IAEA's contributions

    International Nuclear Information System (INIS)

    Ramamoorthy, N.; )

    2007-01-01

    The serendipitous discovery of 99m T c generator at the BNL, USA in 1957 laid the foundation for the subsequent revolution of in vivo imaging of physiological functions in humans to aid diagnostic decisions and patient management. The widespread use of diagnostic imaging in nuclear medicine would not have attained a pre-eminent status world over but for the 99m T c generator and 99m T c labelled products. In order to sustain the nearly 20 million studies annually performed using 99m T c , it is of utmost importance to assure access to appropriate technologies for continued, reliable availability of 99m T c generators and in turn, that of the raw material radionuclide 99 Mo required in extremely large quantities. A walk down the path of their production technologies to trace the trends and issues reveals several major milestones. The IAEA has been involved for well over three decades in fostering developments in 99m T c generator systems through (i) implementation of a number of CRPs including an on-going one related to the production of 99 Mo using LEU targets, (ii) arranging expert reviews through Technical/Consultancy Meetings and (iii) publication of various technical documents, e.g. IAEA-TECDOC: 515 (1989), 852, (1995), 1051 (1998) and 1065 (1999). The IAEA has also supported a number of interested Member States in establishing and/or operating 99m T c generator production facilities, as for example in Bangladesh, China, Indonesia, Iran, Pakistan and Syria. The author has been involved in several of the above initiatives of the IAEA and was also an active participant in the Indian programmes on 99m T c generators during 1972 to 2003. The present review is accordingly tailored as a narration, interspersed with the IAEA's important contributions and glimpses of the Indian scenario. (author)

  7. 7 CFR 1710.119 - Loan processing priorities.

    Science.gov (United States)

    2010-01-01

    ... and Basic Policies § 1710.119 Loan processing priorities. (a) Generally loans are processed in... in effect at the time the facilities were originally constructed; (3) To finance the capital needs of...

  8. Studies of the effect of irradiation in a nuclear reactor, of targets containing Mo used for the preparation of 99Mo gel, material that constitutes the 99Mo - 99mTc generators

    International Nuclear Information System (INIS)

    Nieto, Renata Correa

    2004-01-01

    The most used radioisotope in Nuclear Medicine is 99m Tc, obtained in the 99 Mo - 99m Tc generator form. 99 Mo can be produced by several nuclear reactions in Cyclotron and Reactor. The production in Cyclotron is not technically and commercially feasible. The production in Nuclear Reactor can be made in two ways: 235 U fission and 99 Mo (n,γ) 99 Mo reaction. A project aiming the production of 99 Mo by activation of Mo is under way at IPEN, producing a gel type MoZr generator. There are two ways of preparing the gel and the generators: by irradiating MoO 3 and preparing the gel or by the preparation of the gel and further irradiation. This work consists in the study of the irradiation effects in several targets containing Mo for the production of 99 Mo by the 98 Mo (n,γ) 99 Mo reaction and further preparation of the gel for use as a gel type 99 Mo - 99m Tc generator. Three rinds of gel were studied: zirconium, titanium and cerium molybdate, and their morphology, infrared structure and elution yield of 99m Tc were analysed. The best results were achieved with the generators prepared with MoZr post formed gel, with amorphous structure and better elution yields. The pre formed gel induced crystallinity and worst performance of the generators. (author)

  9. Technetium-99m Sestamibi in Multiple Myeloma

    International Nuclear Information System (INIS)

    Saber, R.A.

    2002-01-01

    Technetium-99m 2-methoxy - isobutyl - isonitrile (99mTc-MIBI) has been reported to be useful in evaluating patients with multiple myeloma. The aim of this study is to evaluate the role of technetium-99m sestamibi (99mTc-MIBI) scintigraphy in the diagnosis. staging and follow-up of patients with multiple myeloma. Methods and Materials: twenty-five consecutive patients with multiple myeloma were studied using 99mTc- MIBI. Of the 25 patients included in this study, 6 were in stage I, II in stage II and 8 in stage III. Anterior and posterior whole-body imaging were obtained 20 min after I.V. injection of 740 MBq of 99mTc-MIBI. Four different MIBI patterns could be described in our patients: physiological (P), diffuse (D), focal (F) and combined diffuse and focal (D+F). All patients in stages II and III as well as 3 patients in stage I were treated with chemotherapy (cyclophosphamide and prednisone) then 99mTc-MlBI scans were repeated after 6 courses. Results: in comparison to conventional X-ray skeletal survey, 99mTc-MIBI scans showed a higher number of myeloma bone disease at diagnosis. All patients with stage II and III multiple myeloma were positive with 99mTc-MlBl scans at diagnosis. The pattern of positive MIBI accumulation was diffuse in 13 (52%) patients, focal in 4 (16%) and combined focal and diffuse in 6 (24%) patients. The intensity of 99mTc-MIBI correlated with disease activity as determined by lactate dehydrogenase (LDH), number of plasma cells in bone marrow and serum electrophoresis. There was a direct correlation between 99mTc-MIBI scan result and clinical outcome of patients following 6 courses of chemotherapy. Sensitivity and specificity of 99mTc-MIBI scintigraphy in detecting myeloma bone lesions were 92% and 90% respectively. Conclusion: 99mTc-MIBI scintigraphy is a reliable method to evaluate bone marrow activity in patients with multiple myeloma and follow-up of myeloma bone lesions

  10. 76 FR 31013 - Proposed Collection; Comment Request for Revenue Procedure 99-17

    Science.gov (United States)

    2011-05-27

    ... Revenue Procedure 99-17 AGENCY: Internal Revenue Service (IRS), Treasury. ACTION: Notice and request for... information collection requirements related to Revenue Procedure 99-17, Mark to Market Election for.... OMB Number: 1545-1641. Revenue Procedure Number: Revenue Procedure 99-17. Abstract: This revenue...

  11. Interesting Features of Ionization Potentials for Elements (Z ≤ 119) along the Periodic Table

    International Nuclear Information System (INIS)

    Gu Chun; Zeng De-Ling; Li Jia-Ming; Jin Rui; Yue Xian-Fang; Gao Xiang

    2016-01-01

    The ionization potential (IP) is a basic property of an atom, which has many applications such as in element analysis. With the Dirac–Slater methods (i.e., mean field theory), IPs of all occupied orbitals for elements with atomic number (Z ≤ 119) are calculated conveniently and systematically. Compared with available experimental measurements, the theoretical accuracies of IPs for various occupied orbitals are ascertained. The map of the inner orbital IPs with good accuracies should be useful to select x-ray energies for element analysis. Based on systematic variations of the first IPs for the outermost orbitals in good agreement with experimental values as well as other IPs, mechanisms of electronic configurations of all atomic elements (Z ≤ 119) along the periodic table are elucidated. It is interesting to note that there exist some deficiencies of the intermediate orbital IPs, which are due to electron correlations and should be treated beyond the mean field theory. (paper)

  12. 14 CFR 99.19-99.31 - [Reserved

    Science.gov (United States)

    2010-01-01

    ... 14 Aeronautics and Space 2 2010-01-01 2010-01-01 false [Reserved] 99.19-99.31 Section 99.19-99.31 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF TRANSPORTATION (CONTINUED) AIR TRAFFIC AND GENERAL OPERATING RULES SECURITY CONTROL OF AIR TRAFFIC General §§ 99.19-99.31 [Reserved] ...

  13. Morphological classification of Renal Disease Using 99mTc-DMSA Scintigram

    International Nuclear Information System (INIS)

    Moon, Tae Yong

    1991-01-01

    99m Tc-DMSA renal scan has been evaluated not only the renal functional cell mass but also some anatomical structures at a loss of the renal parenchymal function. The author classified a renal morphology of the posterior image of 99m Tc-DMSA renal scan as the groups of symmetic and asymmetric morphology, the groups of the large, normal and small sized kidneys, the groups of the central photon defects (PD) which could be noted in a dilated pelvocalyceal system due to obstructive uropathy and the cortical photon defects (CD) due to focal parenchymal lesions or scars after a loss of function and the last groups of the single and multiple CD for a suggestion of the clinical usefulness. Regarding to measurement of norrnal renal size, the longest size of the kidneys were evaluated with 5 cm of a lead scale on the posterior renal image, and those were decided to the limits beteen 104.1 and 119. 4 mm as comparison with the renal size of intravenous pyelogram (IVP) in 59 cases who were underwent 99m Tc-DMSA and IVP concommitantly. Among 85 cases of PD in 99m Tc-DMSA renal scan, the 61 (71.8%) were cases of a dilated pelvocalyceal system related with obstructive uropathy, meanwhile the 28 (27.0%) of 162 cases with CD were cases of obstructive and infectious uropathy. The probability of a presence of some uropathy in cases of CD were 99.3%, meanwhile that of the presence of CD in cases of some uropathy were 37.9%. Besides, there were some specific anatomical findings such as polycystic kidneys with symmetric enlarged kidneys with multiple CD and the kidneys of chronic renal failure and/or hypertension with syrnmetric small size in 99m Tc-DMSA renal scan.

  14. SunBlock '99: Young Scientists Investigate the Sun

    Science.gov (United States)

    Walsh, R. W.; Pike, C. D.; Mason, H.; Young, P.; Ireland, J.; Galsgaard, K.

    1999-10-01

    SunBlock `99 is a Web-based Public Understanding of Science and educational project which seeks to present the very latest solar research as seen through the eyes of young British scientists. These ``solar guides'' discuss not only their scientific interests, but also their extra-curricular activities and the reasons they chose scientific careers; in other words the human face of scientific research. The SunBlock '99 pages gather a range of solar images and movies from current solar space observatories and discuss the underlying physics and its relationship to the school curriculum. The instructional level is pitched at UK secondary school children (aged 13-16 years). It is intended that the material should not only provide a visually appealing introduction to the study of the Sun, but that it should help bridge the often wide gap between classroom science lessons and the research scientist `out in the field'. SunBlock '99 is managed by a team from the Rutherford Appleton Laboratory and the Universities of St Andrews and Cambridge, together with educational consultants. The production has, in part, been sponsored by PPARC and the Millennium Mathematics Project. Web site addresss: http://www.sunblock99.org.uk

  15. 76 FR 30428 - Proposed Collection; Comment Request for Revenue Procedure 99-21

    Science.gov (United States)

    2011-05-25

    ... Revenue Procedure 99-21 AGENCY: Internal Revenue Service (IRS), Treasury. ACTION: Notice and request for...: Disability Suspension. OMB Number: 1545-1649. Revenue Procedure Number: Revenue Procedure 99-21. Abstract: Revenue Procedure 99-21 describes the information that is needed to establish a claim that a taxpayer was...

  16. 46 CFR 119.470 - Ventilation of spaces containing diesel fuel tanks.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 4 2010-10-01 2010-10-01 false Ventilation of spaces containing diesel fuel tanks. 119... fuel tanks. (a) Unless provided with ventilation that complies with § 119.465 of this part, a space containing a diesel fuel tank and no machinery must meet one of the following requirements: (1) A space of 14...

  17. 46 CFR 119.445 - Fill and sounding pipes for fuel tanks.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 4 2010-10-01 2010-10-01 false Fill and sounding pipes for fuel tanks. 119.445 Section... INSTALLATION Specific Machinery Requirements § 119.445 Fill and sounding pipes for fuel tanks. (a) Fill pipes for fuel tanks must be not less than 40 millimeters (1.5 inches) nominal pipe size. (b) There must be...

  18. Maturity of project management in construction companies with the use of fuzzy numbers

    Science.gov (United States)

    Klaus-Rosińska, Agata; Kuchta, Dorota

    2017-07-01

    The main aim of the article is to describe issue of maturity in project management regarding construction companies. Taking into consideration this problem the literature research was made, existing project management maturity models were analyzed, model of maturity in project management (using fuzzy numbers approach) was described and tested. The results of testing stage are shown in the case study.

  19. MM99.81 Projection welding of complex geometries

    DEFF Research Database (Denmark)

    Kristensen, Lars

    The objective of this work has been to establish a profound knowledge about design rules for projection welding geometries dependent of the actual material combination.Design rules and recommendations for geometries and projections in projection welding given in literature is summarised...... and these are catalogued into geometry-classes. A simulation software, SORPAS, based on the finite element method (FEM) is chosen as tool to investigate projection weld quality. SORPAS needs input of the material flow stress as function of strain, strain rate and temperature. Flow stress experiments are performed using...... been investigated.Two different welding geometries, disc with triangular ring projection welded to ring and hat welded to inside hole in ring, are both experimentally and numerically used to investigate the influence of different geometric parameters (thicknesses and angles) on weldability and weld...

  20. Assessment of 99mTc-DMSA renoscintigraphy and uptake compared with creatinine clearance in rats with drug-induced nephrotoxicity, 2

    International Nuclear Information System (INIS)

    Yamada, Masafumi

    1991-01-01

    For evaluation of technetium-99m dimercaptosuccinic acid ( 99m Tc-DMSA) renal uptake as an absolute renal function, 99m Tc-DMSA uptake was compared with endogenous creatinine clearance (Ccr) in cisplatin-induced nephrotoxicity. At first, male Wistar rats were given intraperitoneally 1.8 mg/kg/day of cisplatin for periods of 3, 5, 7 and 9 days. On the next day, 99m Tc-DMSA uptake and Ccr were measured. Ccr of 5-day treated group was significantly lower than that of control (0.13±0.10 vs 0.34±0.05 ml/min/100 g; p 99m Tc-DMSA uptake did not change. 99m Tc-DMSA uptake of 7-day treated group was significantly lower than that of control (28.57±7.23 vs 39.84±2.23%; p 99m Tc-DMSA uptake was lower than that of control on the 8th, 11th and 15th day (32.40±3.86, 32.56±1.19, 35.21±2.97 vs 39.84±2.23%, respectively; p 99m Tc-DMSA uptake and Ccr was observed in the cisplatin-induced nephrotoxicity. 99m Tc-DMSA uptake was suggested to be a reliable indicator of a renal function in a different way from Ccr. (author)

  1. 76 FR 55740 - Proposed Collection; Comment Request for Notice 99-43

    Science.gov (United States)

    2011-09-08

    ... Notice 99-43 AGENCY: Internal Revenue Service (IRS), Treasury. ACTION: Notice and request for comments... Notice 99-43, Nonrecognition Exchanges under Section 897. DATES: Written comments should be received on... Number: Notice 99-43. Abstract: Notice 99-43 announces modification of the current rules under Temporary...

  2. Determination of 99Mo contamination in 99mTc elute obtained from 99Mo/99mTc- generator

    International Nuclear Information System (INIS)

    Momennezhad, M.; Zakavi, S. R.; Sadeghi, R.

    2010-01-01

    99m Tc is a widely used radioisotope in nuclear medicine centers which is obtained by elution from Mo-99/Tc-99m generators. Usually the generators are either supplied by the Iran Atomic Energy Agency or by private companies from foreign countries. In this study we have measured 99 Mo contamination in 99m Tc elute from different generators in a period of one year. Materials and Methods: The radionuclide impurity of the 99m Tc elute were studied in two types of radionuclide generators (A: produced in Iran and B: Imported from other country). In-vitro measurements were performed using dose calibrator. Direct measurements were made, using a standard canister at the time of milking of the generators and also in Subsequent hours after milking. Results: The results showed a mean of 99 Mo impurity in generators A and B to be 0.00932±0.0043 and 0.0170±0.0127 respectively. Although the results showed that the 99 Mo contamination in 99 mTc elute was lesser than the maximum accepted activity limit of 0.015%, the difference in these two types may reflect different methods of productions of generator, as well as the quality control procedures. Conclusion: The mean of 99 Mo contamination in generators produced in Iran Atomic Energy Organization was lesser than generators imported from foreign origin.

  3. 48 CFR 18.119 - Use of patented technology under the North American Free Trade Agreement.

    Science.gov (United States)

    2010-10-01

    ... under the North American Free Trade Agreement. 18.119 Section 18.119 Federal Acquisition Regulations... Available Acquisition Flexibilities 18.119 Use of patented technology under the North American Free Trade Agreement. Requirement to obtain authorization prior to use of patented technology may be waived in...

  4. Minimizing Molybdenum 99 contamination in Technetium 99m Pertechnetate from the elution of 99Mo/ 99m Tc Generator

    International Nuclear Information System (INIS)

    Zakaria Ibrahim; Zulkifli Hashim; Bohari Yaacob

    2011-01-01

    Radioisotope Tc-99m is widely used for variety of nuclear medicine diagnostic procedures. For many commercial applications, it is prepared in a portable type generator. Nuclear Malaysia has been producing a dry type alumina chromatographic column generator utilizing fission Mo-99. This injectable Tc-99m must meet the British Pharmacopeia [1] product specification prior to be apply on patient. This paper provides a method to minimize the up to acceptable level Mo-99 in the final product. Purposely made pertechnetate contaminated with Mo-99 and re-eluate by using old generator. Excellent removal of Mo-99 impurity was achieved and more than 80 % of Tc-99m total activity was recovered. (author)

  5. Income inequality and happiness in 119 nations

    NARCIS (Netherlands)

    M.C. Berg (Maarten); R. Veenhoven (Ruut)

    2010-01-01

    textabstractINCOME INEQUALITY AND HAPPINESS IN 119 NATIONS All modern nations reduce income differences to some extent, and as a result there is an ongoing discussion about what degree of income inequality is acceptable. In this discussion libertarians oppose egalitarians and a principled consensus

  6. Performance tests on new chromatographic material for 99Mo-99mTc generators

    International Nuclear Information System (INIS)

    Sombrito, Elvira Z.; Bulos, Adelina D.M.

    2004-01-01

    Technetium-99m continues to be the main workhorse of nuclear medicine in the Philippines. Almost 13TBq of 99m Tc was imported to the country in 2002 supplied as 99m Tc- 99 Mo generators. These generators make use of fission molybdenum adsorbed onto an alumina column. Problems associated with the alumina chromatographic generators arise due to safety and economic issues that would be remedied by gel-type generators using low specific activity reactor-produced molybdenum-99 adsorbed on a high capacity gel column material. The Philippine Nuclear Research Institute (PNRI) exerted efforts in this direction by developing a gel-type column, which showed satisfactory molybdenum adsorptive capacity. Likewise, Kaken Co. in Japan in cooperation with Japan Atomic Energy Research Institute (JAERI) developed a dried form of a gel-type polyzirconium compound (PZC). It is a ready-to-use high molybdenum capacity column material for adsorbing reactor-produced molybedum-99. The performance of this material is being tested under the framework of the FNCA project on Research Reactor Utilization. Performance tests on four batches of PZC were performed using fission molybdenum eluted from a 99 Mo- 99m Tc generator. A total of 3.3 GBq 99 Mo was extracted from an alumina column of a commercial generator and mixed with carrier molybdenum solution. About 0.67 GBq was loaded into each of the 12 x 90 mm column. One batch was prepared and distributed in 1999 and tests showed very poor elution yield of 30%. Three recent batches of PZC (2002) gave elution yields of 71% (Range of 69-75). The adsorptive capacity is 99% with about 4% desorption rate. Elution volume is at 5-6 ml. Daily elution for five days gave from 1.6 to 5.5% variability. The tests were performed all at the same time and a trend of improving elution yield and consistency of daily elution yield was observed with the time of testing nearer to the sample preparation date. X-ray diffraction analysis showed an amorphous structure for

  7. A comprehensive study on decreasing the kilovoltage cone-beam CT dose by reducing the projection number.

    Science.gov (United States)

    Lu, Bo; Lu, Haibin; Palta, Jatinder

    2010-05-12

    The objective of this study was to evaluate the effect of kilovoltage cone-beam computed tomography (CBCT) on registration accuracy and image qualities with a reduced number of planar projections used in volumetric imaging reconstruction. The ultimate goal is to evaluate the possibility of reducing the patient dose while maintaining registration accuracy under different projection-number schemes for various clinical sites. An Elekta Synergy Linear accelerator with an onboard CBCT system was used in this study. The quality of the Elekta XVI cone-beam three-dimensional volumetric images reconstructed with a decreasing number of projections was quantitatively evaluated by a Catphan phantom. Subsequently, we tested the registration accuracy of imaging data sets on three rigid anthropomorphic phantoms and three real patient sites under the reduced projection-number (as low as 1/6th) reconstruction of CBCT data with different rectilinear shifts and rota-tions. CBCT scan results of the Catphan phantom indicated the CBCT images got noisier when the number of projections was reduced, but their spatial resolution and uniformity were hardly affected. The maximum registration errors under the small amount transformation of the reference CT images were found to be within 0.7 mm translation and 0.3 masculine rotation. However, when the projection number was lower than one-fourth of the full set with a large amount of transformation of reference CT images, the registration could easily be trapped into local minima solutions for a nonrigid anatomy. We concluded, by using projection-number reduction strategy under conscientious care, imaging-guided localization procedure could achieve a lower patient dose without losing the registration accuracy for various clinical sites and situations. A faster scanning time is the main advantage compared to the mA decrease-based, dose-reduction method.

  8. Pairing vibrational and isospin rotational states in a particle number and isospin projected generator coordinate method

    International Nuclear Information System (INIS)

    Chen, H.T.; Muether, H.; Faessler, A.

    1978-01-01

    Pairing vibrational and isospin rotational states are described in different approximations based on particle number and isospin projected, proton-proton, neutron-neutron and proton-neutron pairing wave functions and on the generator coordinate method (GCM). The investigations are performed in models for which an exact group theoretical solution exists. It turns out that a particle number and isospin projection is essential to yield a good approximation to the ground state or isospin yrast state energies. For strong pairing correlations (pairing force constant equal to the single-particle level distance) isospin cranking (-ωTsub(x)) yields with particle number projected pairing wave function also good agreement with the exact energies. GCM wave functions generated by particle number and isospin projected BCS functions with different amounts of pairing correlations yield for the lowest T=0 and T=2 states energies which are practically indistinguishable from the exact solutions. But even the second and third lowest energies of charge-symmetric states are still very reliable. Thus it is concluded that also in realistic cases isospin rotational and pairing vibrational states may be described in the framework of the GCM method with isospin and particle number projected generating wave functions. (Auth.)

  9. Absorbed radiation to the nuclear medicine nurses from patients administered 201Tl and 99mTc- MIBI

    International Nuclear Information System (INIS)

    Sattari, Ali; Dadashzadeh, Simin; Nasiroghli, G.; Firoozabadi, Hasan

    2008-01-01

    People who have administrated radiopharmaceuticals could be a source of radiation to their relatives, medical nurses, and people who have contact them. In this study, the dose rates at various distances of 5, 10,50 and 100 cm from 70 patients, who were administered diagnostic amounts of 201 Tl -Chloride and 99m Tc -MIBI, was measured using an ionization chamber. For determination of external radiation dose to the nurses the radiations in three deferent interval times have measured. The maximum values of external dose rates of 201 Tl and 99m Tc-MIBI were 11.2μSv/h ±2.3 and 43.1μSv/h ±11.9 respectively at 5 cm from the patients. Significant exposure from patients after injection of 99m Tc -MIBI was limited on the day of administration. Departure doses rate of 201 Tl fell gradually so by 3 days after administration was significant. Maximum and average absorbed dose of nuclear medicine staff for one 201 Tl scan was 4.6 and 2.7μSv/h, and for 99m Tc-MIBI was 18.1 and 9.8μSv/h in a working day. (author)

  10. Contracts for field projects and supporting research on enhanced oil recovery. Progress review number 87

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1997-10-01

    Approximately 30 research projects are summarized in this report. Title of the project, contract number, company or university, award amount, principal investigators, objectives, and summary of technical progress are given for each project. Enhanced oil recovery projects include chemical flooding, gas displacement, and thermal recovery. Most of the research projects though are related to geoscience technology and reservoir characterization.

  11. Spent 99Mo/99mTc generator as an economical source of 99Mo

    International Nuclear Information System (INIS)

    El-Kolaly, M.T.

    1990-01-01

    An improved method for utilization and purification of 99 Mo from spent 90 Mo/ 99m Tc generators has been described. After washing the generator with saline to remove the generated 99m Tc, followed by 2 mL 5 M NaOH containing a few drops of H 2 O 2 , the 99 Mo was quantitatively eluted from the generator with 5 mL 5 M NaOH. The alkaline eluate containing 99 Mo was contaminated with partially dissolved alumina. In the present method, an anion-exchange resin Dowex 1 x 8 column was used for purification of 99 Mo from the contaminating alumina. The resultant 99 Mo was of high purity and contained 3+ /mL 99 Mo solution, as estimated by atomic absorption. (author)

  12. Třída, národ a degenerovaná rasa podle českých socialistů (1890-1914)

    Czech Academy of Sciences Publication Activity Database

    Strobach, Vít

    2012-01-01

    Roč. 18, č. 2 (2012), s. 99-119 ISSN 1211-0353 R&D Projects: GA ČR(CZ) GPP410/12/P671 Institutional support: RVO:67985921 Keywords : Czech socialist movement * race * nation Subject RIV: AB - History

  13. An analysis of confidence limit calculations used in AAPM Task Group No. 119

    International Nuclear Information System (INIS)

    Knill, Cory; Snyder, Michael

    2011-01-01

    Purpose: The report issued by AAPM Task Group No. 119 outlined a procedure for evaluating the effectiveness of IMRT commissioning. The procedure involves measuring gamma pass-rate indices for IMRT plans of standard phantoms and determining if the results fall within a confidence limit set by assuming normally distributed data. As stated in the TG report, the assumption of normally distributed gamma pass rates is a convenient approximation for commissioning purposes, but may not accurately describe the data. Here the authors attempt to better describe gamma pass-rate data by fitting it to different distributions. The authors then calculate updated confidence limits using those distributions and compare them to those derived using TG No. 119 method. Methods: Gamma pass-rate data from 111 head and neck patients are fitted using the TG No. 119 normal distribution, a truncated normal distribution, and a Weibull distribution. Confidence limits to 95% are calculated for each and compared. A more general analysis of the expected differences between the TG No. 119 method of determining confidence limits and a more time-consuming curve fitting method is performed. Results: The TG No. 119 standard normal distribution does not fit the measured data. However, due to the small range of measured data points, the inaccuracy of the fit has only a small effect on the final value of the confidence limits. The confidence limits for the 111 patient plans are within 0.1% of each other for all distributions. The maximum expected difference in confidence limits, calculated using TG No. 119's approximation and a truncated distribution, is 1.2%. Conclusions: A three-parameter Weibull probability distribution more accurately fits the clinical gamma index pass-rate data than the normal distribution adopted by TG No. 119. However, the sensitivity of the confidence limit on distribution fit is low outside of exceptional circumstances.

  14. 29 CFR 570.119 - Fourteen-year minimum.

    Science.gov (United States)

    2010-07-01

    ... Regulations Relating to Labor (Continued) WAGE AND HOUR DIVISION, DEPARTMENT OF LABOR REGULATIONS CHILD LABOR REGULATIONS, ORDERS AND STATEMENTS OF INTERPRETATION General Statements of Interpretation of the Child Labor Provisions of the Fair Labor Standards Act of 1938, as Amended Oppressive Child Labor § 570.119 Fourteen-year...

  15. 77 FR 6862 - Proposed Collection; Comment Request for Revenue Procedure 99-50

    Science.gov (United States)

    2012-02-09

    ... Revenue Procedure 99-50 AGENCY: Internal Revenue Service (IRS), Treasury. ACTION: Notice and request for... Revenue Procedure 99-50, Combined Information Reporting. DATES: Written comments should be received on or... Number: Revenue Procedure 99-50. Abstract: Revenue Procedure 99-50 permits combined information reporting...

  16. 40 CFR 86.1729-99-86.1733-99 - [Reserved

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 19 2010-07-01 2010-07-01 false [Reserved] 86.1729-99-86.1733-99 Section 86.1729-99-86.1733-99 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR... Light-Duty Trucks §§ 86.1729-99—86.1733-99 [Reserved] ...

  17. 40 CFR 86.1736-99-86.1769-99 - [Reserved

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 19 2010-07-01 2010-07-01 false [Reserved] 86.1736-99-86.1769-99 Section 86.1736-99-86.1769-99 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR... Light-Duty Trucks §§ 86.1736-99—86.1769-99 [Reserved] ...

  18. 40 CFR 86.1718-99-86.1720-99 - [Reserved

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 19 2010-07-01 2010-07-01 false [Reserved] 86.1718-99-86.1720-99 Section 86.1718-99-86.1720-99 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR... Light-Duty Trucks §§ 86.1718-99—86.1720-99 [Reserved] ...

  19. Direct production of 99mTc using a small medical cyclotron

    Energy Technology Data Exchange (ETDEWEB)

    Lapi, Suzanne [Washington Univ., St. Louis, MO (United States)

    2017-10-03

    This project describes an investigation towards the production of 99mTc with a small medical cyclotron. This endeavor addresses the current urgent problem of availability of 99mTc due to the ongoing production reactor failures and the upcoming Canadian reactor shut down. Currently, 99mTc is produced via nuclear fission using highly enriched uranium which is a concern due to nuclear proliferation risks. In addition to this, the United States is dependent solely on currently unreliable foreign sources of this important medical isotope. Clearly, a need exists to probe alternative production routes of 99mTc. In the first year, this project measured cross-sections and production yields of potential pathways to 99mTc and associated radionuclidic impurities produced via these pathways using a small 15 MeV medical cyclotron. During the second and third years target systems for the production of 99mTc via the most promising reaction routes were developed and separation techniques for the isolation of 99mTc from the irradiated target material will be investigated. Systems for the recycling of the enriched target isotopes as well as automated target processing systems were examined in years four and five. This project has the potential to alleviate some of the current crisis in the medical community by developing a technique to produce 99mTc on location at a university hospital. This technology will be applicable at many other sites in the United States as many other similar, low energy (<20 MeV) cyclotrons (currently used for a few hours per day for the production of [18F]fluorodeoxyglucose) are available for production of 99mTc though this method, thus leading to job creation and preservation.

  20. Poster — Thur Eve — 01: The effect of the number of projections on MTF and CNR in Compton scatter tomography

    International Nuclear Information System (INIS)

    Chighvinadze, T; Pistorius, S

    2014-01-01

    Purpose: To investigate the dependence of the reconstructed image quality on the number of projections in multi-projection Compton scatter tomography (MPCST). The conventional relationship between the projection number used for reconstruction and reconstructed image quality pertained to CT does not necessarily apply to MPCST, which can produce images from a single projection if the detectors have sufficiently high energy and spatial resolution. Methods: The electron density image was obtained using filtered-backprojection of the scatter signal over circular arcs formed using Compton equation. The behavior of the reconstructed image quality as a function of the projection number was evaluated through analytical simulations and characterized by CNR and MTF. Results: The increase of the projection number improves the contrast with this dependence being a function of fluence. The number of projections required to approach the asymptotic maximum contrast decreases as the fluence increases. Increasing projection number increases the CNR but not spatial resolution. Conclusions: For MPCST using a 500eV energy resolution and a 2×2mm 2 size detector, an adequate image quality can be obtained with a small number of projections provided the incident fluence is high enough. This is conceptually different from conventional CT where a minimum number of projections is required to obtain an adequate image quality. While increasing projection number, even for the lowest dose value, the CNR increases even though the number of photons per projection decreases. The spatial resolution of the image is improved by increasing the sampling within a projection rather than by increasing the number of projections

  1. Effects of particle-number-projection on nuclear moment of intertia

    International Nuclear Information System (INIS)

    Rozmej, P.

    1976-01-01

    The formalism of the moment of inertia in cranking model and BCS theory has been extended for the partially particle-number-projected BCS wave functions. The ground state moments of inertia obtained by this method are a little greater than those calculated by BCS method. A smooth growth of the moments of inertia for diminishing pairing strength constant has been obtained. (author)

  2. Successful labeling of 99mTc-MDP using 99mTc separated from 99Mo produced by 100Mo(n,2n)99Mo

    International Nuclear Information System (INIS)

    Nagai, Yasuki; Hatsukawa, Yuichi; Kin, Tadahiro; Hashimoto, Kazuyuki; Motoishi, Shoji; Konno, Chikara; Ochiai, Kentaro; Takakura, Kosuke; Sato, Yuichi; Sato, Norihito; Ohta, Akio; Yamabayashi, Hisamichi; Tanase, Masakazu; Fujisaki, Saburo; Kawauchi, Yukimasa; Teranaka, Tomoyuki; Takeuchi, Nobuhiro; Igarashi, Takashi

    2011-01-01

    We have for the first time succeeded in separating 99m Tc from a MoO 3 sample irradiated with accelerator neutrons free from any radioactive impurities and in formulating 99m Tc-methylene diphosphonate ( 99 mTc-MDP). 99 Mo, the mother nuclide of 99m Tc, was produced by the 100 Mo(n,2n) 99 Mo reaction using about 14 MeV neutrons provided by the 3 H(d,n) 4 He reaction at the Fusion Neutronics Source of Japan Atomic Energy Agency. The 99m Tc was separated from 99 Mo by sublimation and its radionuclide purity was confirmed to be higher than 99.99% by γ-spectroscopy. The labeling efficiency of 99m Tc-MDP was shown to be higher than 99% by thin-layer chromatography. These values exceed the United States Pharmacopeia requirements for a fission product, 99 Mo. Consequently, a 99m Tc radiopharmaceutical preparation formed by using the mentioned 99 Mo can be a promising substitute for the fission product 99 Mo, which is currently produced using a highly enriched uranium target in aging research reactors. A longstanding problem to ensure a reliable and constant supply of 99 Mo in Japan can be partially mitigated. (author)

  3. Photothermal deflection mapping of variations in the optical absorption in IR windows

    Czech Academy of Sciences Publication Activity Database

    Remeš, Zdeněk; Nesládek, M.; Meykens, K.; Pickles, C. S. J.; Sussman, R. S.

    2000-01-01

    Roč. 181, - (2000), s. 115-119 ISSN 0031-8965 R&D Projects: GA ČR GA202/99/0403 Institutional research plan: CEZ:AV0Z1010914 Subject RIV: BM - Solid Matter Physics ; Magnetism Impact factor: 1.035, year: 2000

  4. Development of the Mo loading apparatus for adsorbing high level 99Mo to PZC and packing in 99mTc generator column

    International Nuclear Information System (INIS)

    Hishinuma, Yukio; Ohmori, Hiroyuki; Noguchi, Tuneyuki; Tatenuma, Katsuyoshi; Genka, Tsuguo; Machi, Sueo

    2006-01-01

    For developing the automatic system to produce the PZC- 99m Tc generator column based on (n, gamma) method, we developed and fabricated the proto-type apparatus for semi hot test to prepare and pack PZC adsorbed 99 Mo produced by (n, gamma) method into the generator column; PZC is Mo adsorbent with practical performance for (n, gamma) 99m Tc generator with high 99 Mo adsorption and high 99m Tc elution. For conducting the constant supply and delivery of 99m Tc generator, it is necessary to establish the technology of (n, gamma) method 99m Tc generator using PZC and to develop the fabrication system for 99 Mo loading to PZC and packing the 99m Tc generator column. By the reason, we are developing the Mo loading apparatus. In order to automatically conduct the process of 99 Mo adsorption to PZC and PZC- 99 Mo packing into the generator column, based on one channel system developed by JAERI-KAKEN at 3 years ago, an advanced automatic loading system functioned with 8 channels was developed as FNCA project proceeded by the core with Kaken Co. and JAIF for realizing a mass production of 99m Tc generators, and moreover the Japanese patent regarding the PZC- 99m Tc generator including the automatic loading system of 99 Mo to PZC and making 99m Tc generator columns has already been applied with joint applicants of BATAN and Kaken Co. Regarding the multi-type Mo loading apparatus mentioned above, we set it up in a hot of BATAN at December 2003 year. In this report, we will introduce mainly about the multi-channel automatic loading system of 99 Mo. (author)

  5. 14 CFR 119.67 - Management personnel: Qualifications for operations conducted under part 121 of this chapter.

    Science.gov (United States)

    2010-01-01

    ... or Part 135 of This Chapter § 119.67 Management personnel: Qualifications for operations conducted... 14 Aeronautics and Space 3 2010-01-01 2010-01-01 false Management personnel: Qualifications for operations conducted under part 121 of this chapter. 119.67 Section 119.67 Aeronautics and Space FEDERAL...

  6. 14 CFR 119.71 - Management personnel: Qualifications for operations conducted under part 135 of this chapter.

    Science.gov (United States)

    2010-01-01

    ... or Part 135 of This Chapter § 119.71 Management personnel: Qualifications for operations conducted... 14 Aeronautics and Space 3 2010-01-01 2010-01-01 false Management personnel: Qualifications for operations conducted under part 135 of this chapter. 119.71 Section 119.71 Aeronautics and Space FEDERAL...

  7. 27 CFR 20.119 - Toilet preparations containing not less than 10% essential oils general-use formula.

    Science.gov (United States)

    2010-04-01

    ... containing not less than 10% essential oils general-use formula. 20.119 Section 20.119 Alcohol, Tobacco....119 Toilet preparations containing not less than 10% essential oils general-use formula. This general-use formula shall consist of an article containing not less than 10% essential oils by volume made...

  8. Effect of milking efficiency on Tc-99 content of Tc-99m derived from Tc-99m generators

    International Nuclear Information System (INIS)

    Bonnyman, J.

    1983-01-01

    Tc-99m obtained by separation from its parent Mo-99 always contains Tc-99 produced by decay of Tc-99m and Mo-99. Factors effecting the Tc-99/Tc-99m ratios are discussed. An HPLC method has been developed to measure the 99 TcO 4- content of sodium pertechnetate from generators with a detection limit of 0.9 ng Tc-99 for a 500 μl/ aliquot of TcO 4- -99m. First eluates of 10 chromatograph-ic generators gave Tc-99/Tc-99m ratios ranging from 3.5-46 ng Tc/mCi Tc-99m measured at the time of milking. The measurements indicate that Tc-99/Tc-99m ratios high enough to cause adverse labelling effects could be found in 'instant pertechnetate' and in the first eluate from Tc-99m generators for the activities normally used in radiopharmaceutical production

  9. Production technologies for molybdenum-99 and technetium-99m

    International Nuclear Information System (INIS)

    1999-02-01

    Technetium-99m (6.02 h) is the most widely used radioisotope in nuclear medicine, accounting for more than 80% of all diagnostic nuclear medicine procedures. It is almost exclusively produced from the decay of its parent 99 Mo. The present sources of 99 Mo are research reactors by using the (n,γ) nuclear reaction with natural Mo ( 98 Mo, ∼24%), resulting in inexpensive but low-specific activity 99 Mo, or by neutron-induced fission of 235 U, which results in expensive but high specific activity 99 Mo. This publication covers several aspects related to the production of 99 Mo and 99m Tc. The contributed papers reflect the current status of the technology and discuss potential alternative methodologies for the production of 99 Mo and 99m Tc for medical use. The first four papers address the technologies using nuclear reactors, including the description of a new method using an aqueous homogenous reactor core for production of fission 99 Mo and the latest development efforts to fabricate 235 U low enriched targets (LEU, 235 U). The next five papers discuss the potential of utilizing particle accelerators and assess the current status of the available nuclear data for the production of both, 99 Mo and 99m Tc with proton and deuteron beams. The last paper discusses a new technology based on gel system for the preparation of 99 Mo/ 99m Tc generators using low specific activity 99 Mo produced in research reactors by the neutron activation of natural and inexpensive molybdenum oxide targets. Each individual paper was indexed and abstracted

  10. Energy research program 99. Program for expansion of the Danish energy research and development in the period 1999-2001

    International Nuclear Information System (INIS)

    2000-08-01

    The present 'Energy research program 99' contains descriptions of projects under The Energy Research Programme (EFP) supported by the Danish Energy Agency. The research programme covers the areas Fuel oils and natural gas, biomass, production and distribution of electric power and heating, wind energy, energy consumption in buildings, solar energy, energy conservation, fuel cells, super conductors, industrial processes and international co-operation. The manuscript is based on print-outs of the Danish input from the database Nordic Energy Index (NEI). The descriptions give project titles, summary descriptions of aims, methods etc., names, addresses, telephone and tele fax numbers of institutions etc. responsible for the projects, names of project leaders, of other involved firms, institutes or institutions, and details of the total budget and the financing of the energy research projects. (EHS)

  11. Number names and number understanding

    DEFF Research Database (Denmark)

    Ejersbo, Lisser Rye; Misfeldt, Morten

    2014-01-01

    This paper concerns the results from the first year of a three-year research project involving the relationship between Danish number names and their corresponding digits in the canonical base 10 system. The project aims to develop a system to help the students’ understanding of the base 10 syste...... the Danish number names are more complicated than in other languages. Keywords: A research project in grade 0 and 1th in a Danish school, Base-10 system, two-digit number names, semiotic, cognitive perspectives....

  12. A draft plan for the routine production of PZC based 99mTc generator in the Vietnam

    International Nuclear Information System (INIS)

    Duong Van Dong

    2007-01-01

    This is an outline of the radioisotope production programme using a research reactor of 500 kW in Vietnam. Under the framework of Forum for Nuclear Cooperation in Asia (FNCA) cooperation program, the PZC based technology for production of 99m Tc-generator has been studied at Dalat Nuclear Research Institute (DNRI) as well as FNCA members countries in the past several years. The FNCA project has shown the feasibility of using a PZC column-reactor 99 Mo- 99m Tc-generator for commercial applications, citing mainly the cheaper cost of the PZC generator than the imported alumina column-fission 99 Mo generator and excellent technology achievement has been established and optimized by close cooperation between FNCA country members and KAKEN, JAERI. DNRI proposes in this draft business plan, the commercial production of PZC generator through the establishment of national project stage 2006-2008 for the routine production of 99 Mo- 99m Tc generator. In this national project the 99m Tc-generator will use PZC coming from KAKEN - Japan or locally synthesis as the column material, 99 Mo sourced from neighboring countries or irradiated at or reactor and the semi-automatic loading and adsorption machine will be studied, designed and installed in the hot cells available. Because the DNRI have facility 99m Tc-generator production line with two hot cells used production of the 99m Tc generator by using fission 99 Mo. The generator assembly will be designed and fabricated. (author)

  13. Fit for competition with ``EVS `99``; Mit ``EVS `99`` fit fuer den Wettbewerb

    Energy Technology Data Exchange (ETDEWEB)

    Klawunn, K.H.; Wamhof, F. [Energieversorgung Suedsachsen AG, Chemnitz (Germany)

    1998-05-01

    The Energieversorgung Suedsachsen AG (EVS AG) located in Chemnitz faces up to the challenges of the competitive energy market. The company launched the project ``EVS `99`` in order to achieve the essential strategic goals: increase customer loyalty, concentrate on the core business, open up new operating areas, improve the core competences. This comprehensive business re-engineering project is intended to realise by the end of the business year 1997/98 an optimisation of all essential business processes, which are to focus on customer needs, establishment of an efficient, customer-oriented organisation in line with the strategy, and design of the required management and control systems. The technical and communication systems will be based on the SAP R/3 software in order to fully exploit the optimisation potentials. (orig./CB) [Deutsch] Die Energieversorgung Suedsachsen AG (EVS AG) in Chemnitz stellt sich aktiv den Herausforderungen des Wettbewerbs. Um die strategischen Unternehmensziele Erhoehung der Kundenbindung, Konzentration auf das Kerngeschaeft, Erschliessung neuer Geschaeftsfelder und Verbesserung der Kernkompetenzen zu erreichen, wurde das Projekt `EVS `99` initiiert. Durch dieses umfassende Business-Reengineering-Projekt wird bis Ende des Geschaeftsjahres 1997/98 die Optimierung aller wesentlichen Geschaeftsprozesse und deren Ausrichtung an den Kundenanforderungen, der Aufbau einer strategiekonformen, effizienten, kundenorientierten Organisation und die Gesaltung anforderungsgerechter Fuehrungs- und Steuerungssysteme realisiert. Begleitend wird die Software SAP R/3 im Unternehmen eingefuehrt, um umfassend, d.h. bereichsuebergreifend, alle Optimierungspotentiale zu nutzen. (orig./RHM)

  14. Simultaneous projection of particle-number and angular momentum BCS wave-functions in the rare-earth nuclei

    International Nuclear Information System (INIS)

    Oudih, M.R.; Benhamouda, N.; Fellah, M.; Allal, N.H.

    2000-01-01

    A method of simultaneous particle-number and angular-momentum projection of the BCS wave-function is presented. The particle number projection method is of FBCS type. In the frame work of the adiabatic approximation, the rotational energies of the axially symmetric even-even nuclei are established and numerically calculated for the rare-earth region. (author)

  15. Practical project management: tips, tactics, and tools

    National Research Council Canada - National Science Library

    Levine, Harvey A

    2002-01-01

    ... Elements of Resource Management 4.2 Role-based Needs for Managing Resources in a Project-driven Organization 4.3 Resource Leveling and Games of Chance 4.4 Practical Resource Scheduling 117 119 12...

  16. ID card number detection algorithm based on convolutional neural network

    Science.gov (United States)

    Zhu, Jian; Ma, Hanjie; Feng, Jie; Dai, Leiyan

    2018-04-01

    In this paper, a new detection algorithm based on Convolutional Neural Network is presented in order to realize the fast and convenient ID information extraction in multiple scenarios. The algorithm uses the mobile device equipped with Android operating system to locate and extract the ID number; Use the special color distribution of the ID card, select the appropriate channel component; Use the image threshold segmentation, noise processing and morphological processing to take the binary processing for image; At the same time, the image rotation and projection method are used for horizontal correction when image was tilting; Finally, the single character is extracted by the projection method, and recognized by using Convolutional Neural Network. Through test shows that, A single ID number image from the extraction to the identification time is about 80ms, the accuracy rate is about 99%, It can be applied to the actual production and living environment.

  17. Tumor affinity of technetium-99m labeled radiopharmaceuticals. II. Sup(99m)Tc-Sn-diphosphonate (sup(99m)Tc-EHDP), sup(99m)Tc-Sn-dimercaptosuccinic acid (sup(99m)Tc-DMSA), sup(99m)Tc-Sn-diethyl stilbestrol diphosphate (sup(99m)Tc-DSDP)

    Energy Technology Data Exchange (ETDEWEB)

    Itoh, K; Kobayashi, S; Hisada, K; Tonami, N [Kanazawa Univ. (Japan). School of Medicine; Ando, A

    1976-10-01

    The authors have examined the tumor affinity of various sup(99m)Tc-labelled radiopharmaceuticals to Ehrlich's tumor for the purpose of delineating human malignant neoplasm positively. The biologic distributions of sup(99m)Tc-Sn-diphosphonate (sup(99m)Tc-EHDP), sup(99m)Tc-Sn-dimercaptosuccinic acid (sup(99m)Tc-DMSA) and sup(99m)Tc-Sn-diethyl stilbestrol diphosphate (sup(99m)Tc-DSDP, sup(99m)Tc-Honvan) are included as the second report on the tumor affinity of Ehrlich-bearing mice. Tumor concentration of sup(99m)Tc-EHDP was lowest and the positive delineation of implanted tumor with sup(99m)Tc-EHDP was poorest in sequential images, though active accumulation in some soft tissues malignant neoplasms, breast cancer, and thyroid cancer, has been reported. Tumor concentration and the tumor-to-blood ratio of sup(99m)Tc-DMSA were not so high, contrary to our expectation that /sup 197/Hg-DMSA might show high tumor concentration and high tumor-to-blood ratio the same as /sup 197/Hg chlormerodrin of the renal scanning radiopharmaceuticals. Tumor concentration of sup(99m)Tc-DSDP was highest. The tumor-to-blood concentration ratio was lower than that of the above mentioned radiopharmaceuticals but the tumor-to-liver ratio and/or tumor-to-lung ratio was over 1.0 at the earlier time. Biologic distribution of sup(99m)Tc-DSDP was similar to that of /sup 32/P labeled DSDP. It is presumed that sup(99m)Tc is labeled at the phosphate ester of DSDP which is dephospholytated immediately by phospholylase in vivo following intravenous injection. Although it is not known precisely it may be assumed that the mechanism of accumulating sup(99m)Tc-DSDP in Ehrlich's tumor is related to the phospholylase activity in neoplasms.

  18. Diversification of 99Mo/99mTc separation: non–fission reactor production of 99Mo as a strategy for enhancing 99mTc availability.

    Science.gov (United States)

    Pillai, Maroor R A; Dash, Ashutosh; Knapp, Furn F Russ

    2015-01-01

    This paper discusses the benefits of obtaining (99m)Tc from non-fission reactor-produced low-specific-activity (99)Mo. This scenario is based on establishing a diversified chain of facilities for the distribution of (99m)Tc separated from reactor-produced (99)Mo by (n,γ) activation of natural or enriched Mo. Such facilities have expected lower investments than required for the proposed chain of cyclotrons for the production of (99m)Tc. Facilities can receive and process reactor-irradiated Mo targets then used for extraction of (99m)Tc over a period of 2 wk, with 3 extractions on the same day. Estimates suggest that a center receiving 1.85 TBq (50 Ci) of (99)Mo once every 4 d can provide 1.48-3.33 TBq (40-90 Ci) of (99m)Tc daily. This model can use research reactors operating in the United States to supply current (99)Mo needs by applying natural (nat)Mo targets. (99)Mo production capacity can be enhanced by using (98)Mo-enriched targets. The proposed model reduces the loss of (99)Mo by decay and avoids proliferation as well as waste management issues associated with fission-produced (99)Mo.

  19. Toepassing WAPRO; versie99. Tevens achtergronddocument van de Nationale Milieuverkenning 2000-2030

    NARCIS (Netherlands)

    Mulschlegel JHC; Hart MJ 't; LWD

    2000-01-01

    The study presented here consisted of a small analysis of the water demand in the past and a calculation of future demand using the WAPRO99 model (computer model to calculate projections of water consumption and production). Also described is how WAPRO99 has been used for the National Environmental

  20. Distributed production system for 99mTc-I: System overview

    International Nuclear Information System (INIS)

    Bennett, R.G.; Terry, W.K.; Grover, S.B.

    1997-01-01

    Technetium-99m is the radioisotope of choice for >80% of all nuclear medical imaging procedures today in the United States. There are > 12 million 99m Tc scans performed in the United States per year. Since the development of fission-based radio nuclide generators for 99 Mo, 99m Tc use has grown steadily over the past 20 yr. Despite the widespread demand for 99m Tc in medicine, a reliable and assured supply of the parent, 99 Mo, does not exist. Construction of Maple-1 and -2, two new Canadian isotope production reactors intended to replace the aging National Research Universal (NRU) reactor, has been approved in an agreement among Atomic Energy of Canada Limited, MDS Nordion, and the Canadian government. However, the project is expensive: The anticipated cost of Maple-1 and -2 is $C140 million. Outlays toward this cost have recently driven the price of 99 Mo up by 40%, even though the Canadian 99 Mo production will continue to be heavily subsidized by an interest-free construction loan. Research and development for an accelerator-based facility has been undertaken and is described

  1. Status of Tc-99m and 99Mo/99mTc generator production in Bangladesh

    International Nuclear Information System (INIS)

    Abedin, Md. Zainul; Haque, Md. Azizul; Ali, Md. Ramjan; Hossain, Md. Anwar; Razzaque, Md. Abdur; Yasmin, Lyzu; Waheed, M. Fatima; Akhter, Rabeya; Mondal, Rafiuddin

    2007-01-01

    Radioisotope Production Division (RIPD) produced instant technetium-99m by solvent extraction method for several years. On R and D basis, the division produced portable sterile Tc-99m sublimation generator by irradiating titanium molybdate in the reactor. The division produced (4/batch) from imported fission Mo-99 till June 2005. Since August 2005, as per demand of the government hospitals, the division have been producing 12-14 pieces of 15 GBq chromatographic 99m Tc-generators weekly by using the new generator production plant installed last year having online Mo-99 loading system with the of producing 50 generator per batch. Development of PZC and (n,γ) 99 Mo based generator holds potential in Bangladesh. (author)

  2. Pharmaceutical grade sodium (99mTc) pertechnetate from 99Mo/99mTc-TCM-Autosolex generator

    International Nuclear Information System (INIS)

    Chattopadhyay, Sankha; Barua, Luna; Das, Sujata Saha

    2014-01-01

    Technetium-99m (T 1/2 = 6.02h; 140.51 keV (89%)) is the most useful radioisotope in diagnostic nuclear medicine. More than 80% of all diagnostic procedures done worldwide in nuclear medicine centre are performed with 99m Tc. Worldwide crisis of fission 99 Mo based generator in recent past had put the nuclear medicine fraternity in very harsh situation. In order to have an indigenous solution of this problem, we tried to develop a computer controlled semi automated 99 Mo/ 99m Tc generator using MEK solvent extraction technique, which utilizes abundantly available 99 Mo produced by (n,γ) reaction in BARC reactors. The aim of this work is to provide a more reliable, computer controlled module (TCM- AUTOSOLEX) for the recovery of pharmaceutical grade 99m Tc from low specific activity 99 Mo based on solvent extraction methodology

  3. Purification and characterization of enterocin FH 99 produced by a faecal isolate Enterococcus faecium FH 99.

    Science.gov (United States)

    Gupta, H; Malik, R K; Bhardwaj, A; Kaur, G; De, S; Kaushik, J K

    2010-06-01

    Enterococcus faecium FH 99 was isolated from human faeces and selected because of its broad spectrum of inhibitory activity against several Gram-positive foodborne spoilage and pathogenic bacteria. Ent. faecium FH 99 accumulates enterocin in large number in early stationary phase of the growth. The enterocin FH 99 was stable over a wide pH range (2-10) and recovered activity even after treatment at high temperatures (10 min at 100°C). The enterocin was subjected to different purification techniques viz., gel filteration, cation exchange chromatography and reverse-phase high-performance liquid chromatography. The activity was eluted as one individual active fraction. SDSPAGE revealed a molecular weight of less than 6.5 kDa. Studies carried out to identify the genetic determinants for bacteriocin production showed that this trait may be plasmid encoded as loss in both of the plasmids (size>chromosomal DNA) led to loss in bacteriocin production by Ent. faecium FH 99. Ent. faecium strain FH 99 is a newly discovered high bacteriocin producer with Activity Units 1.8 × 10(5) AU ml(-1) and its characteristics indicate that it may have strong potential for application as a protective agent against pathogens and spoilage bacteria in foods.

  4. The Folding of de Novo Designed Protein DS119 via Molecular Dynamics Simulations

    Directory of Open Access Journals (Sweden)

    Moye Wang

    2016-04-01

    Full Text Available As they are not subjected to natural selection process, de novo designed proteins usually fold in a manner different from natural proteins. Recently, a de novo designed mini-protein DS119, with a βαβ motif and 36 amino acids, has folded unusually slowly in experiments, and transient dimers have been detected in the folding process. Here, by means of all-atom replica exchange molecular dynamics (REMD simulations, several comparably stable intermediate states were observed on the folding free-energy landscape of DS119. Conventional molecular dynamics (CMD simulations showed that when two unfolded DS119 proteins bound together, most binding sites of dimeric aggregates were located at the N-terminal segment, especially residues 5–10, which were supposed to form β-sheet with its own C-terminal segment. Furthermore, a large percentage of individual proteins in the dimeric aggregates adopted conformations similar to those in the intermediate states observed in REMD simulations. These results indicate that, during the folding process, DS119 can easily become trapped in intermediate states. Then, with diffusion, a transient dimer would be formed and stabilized with the binding interface located at N-terminals. This means that it could not quickly fold to the native structure. The complicated folding manner of DS119 implies the important influence of natural selection on protein-folding kinetics, and more improvement should be achieved in rational protein design.

  5. Material decomposition in an arbitrary number of dimensions using noise compensating projection

    Science.gov (United States)

    O'Donnell, Thomas; Halaweish, Ahmed; Cormode, David; Cheheltani, Rabee; Fayad, Zahi A.; Mani, Venkatesh

    2017-03-01

    Purpose: Multi-energy CT (e.g., dual energy or photon counting) facilitates the identification of certain compounds via data decomposition. However, the standard approach to decomposition (i.e., solving a system of linear equations) fails if - due to noise - a pixel's vector of HU values falls outside the boundary of values describing possible pure or mixed basis materials. Typically, this is addressed by either throwing away those pixels or projecting them onto the closest point on this boundary. However, when acquiring four (or more) energy volumes, the space bounded by three (or more) materials that may be found in the human body (either naturally or through injection) can be quite small. Noise may significantly limit the number of those pixels to be included within. Therefore, projection onto the boundary becomes an important option. But, projection in higher than 3 dimensional space is not possible with standard vector algebra: the cross-product is not defined. Methods: We describe a technique which employs Clifford Algebra to perform projection in an arbitrary number of dimensions. Clifford Algebra describes a manipulation of vectors that incorporates the concepts of addition, subtraction, multiplication, and division. Thereby, vectors may be operated on like scalars forming a true algebra. Results: We tested our approach on a phantom containing inserts of calcium, gadolinium, iodine, gold nanoparticles and mixtures of pairs thereof. Images were acquired on a prototype photon counting CT scanner under a range of threshold combinations. Comparison of the accuracy of different threshold combinations versus ground truth are presented. Conclusions: Material decomposition is possible with three or more materials and four or more energy thresholds using Clifford Algebra projection to mitigate noise.

  6. Cyclotron production of molybdenum-99 via proton-induced uranium-238 fission

    International Nuclear Information System (INIS)

    Lagunas-Solar, M.C.; Zeng, N.X.; Mirshad, I.; Castaneda, C.M.

    1996-01-01

    Technetium-99m ( 99m Tc; 6.02 h) is the most widely used radioisotope in nuclear medicine worldwide. It is currently supplied from elutions of a 99 Mo → 99m Tc generator and used for regional distribution or locally for institutional use. The parent 99 Mo (66.02 h) radioactivities are being produced commercially in reactors using the 235 U(n, fission) 99 Mo (preferred method) or the 98 Mo(n,γ) 99 Mo (less desirable) methods. The production of 99 Mo is based on the operation of a small number of nuclear reactors, most of which have reached decommissioning age. Two new reactors to be dedicated to radioisotope production are now being planned in Canada. Accelerator-based methods for producing 99 Mo and/or 99m Tc would then provide new alternatives to the current reliance on reactor-based technologies

  7. Bidirectional GPR119 agonism requires peptide YY and glucose for activity in mouse and human colon mucosa

    DEFF Research Database (Denmark)

    Tough, Iain R; Forbes, Sarah; Herzog, Herbert

    2018-01-01

    motility in wild-type (WT), GPR119-/- and PYY-/- mice.The water-soluble GPR119 agonist, AR440006 (that cannot traverse epithelial tight-junctions) elicited responses when added apically or basolaterally in mouse and human colonic mucosas. In both species, GPR119 responses were PYY, Y1 receptor...

  8. Influence of sampling interval and number of projections on the quality of SR-XFMT reconstruction

    International Nuclear Information System (INIS)

    Deng Biao; Yu Xiaohan; Xu Hongjie

    2007-01-01

    Synchrotron Radiation based X-ray Fluorescent Microtomography (SR-XFMT) is a nondestructive technique for detecting elemental composition and distribution inside a specimen with high spatial resolution and sensitivity. In this paper, computer simulation of SR-XFMT experiment is performed. The influence of the sampling interval and the number of projections on the quality of SR-XFMT image reconstruction is analyzed. It is found that the sampling interval has greater effect on the quality of reconstruction than the number of projections. (authors)

  9. Novel Approach to Prepare {sup 99m}Tc-Based Multivalent RGD Peptides

    Energy Technology Data Exchange (ETDEWEB)

    Shuang Liu

    2012-10-24

    This project presents a novel approach to prepare the {sup 99m}Tc-bridged multivalent RGD (arginine-glycine-aspartate) peptides. This project will focus on fundamentals of {sup 99m}Tc radiochemistry. The main objective of this project is to demonstrate the proof-of-principle for the proposed radiotracers. Once a kit formulation is developed for preparation of the {sup 99m}Tc-bridged multivalent RGD peptides, various tumor-bearing animal models will be used to evaluate their potential for SPECT (single photon-emission computed tomography) imaging of cancer. We have demonstrated that (1) multimerization of cyclic RGD peptides enhances the integrin {alpha}{sub v}{beta}{sub 3} bonding affinity and radiotracer tumor uptake; (2) addition of G{sub 3} or PEG{sub 4} linkers makes it possible for two RGD motifs in 3P-RGD{sub 2} and 3G-RGD{sub 2} to achieve simultaneous integrin {alpha}{sub v}{beta}{sub 3} binding; and (3) multimers are actually bivalent (not multivalent), the presence of extra RGD motifs can enhance the tumor retention time of the radiotracer.

  10. Developing Techniques for Small Scale Indigenous Molybdenum-99 Production Using LEU Fission at Tajoura Research Center-Libya [Country report: Libya

    International Nuclear Information System (INIS)

    Alwaer, Sami M.

    2015-01-01

    The object of this work was to assist the IAEA by providing the Libyan country report about the Coordination Research Project (CRP), on the subject of “Developing techniques for small scale indigenous Mo-99 production using LEU-foil” which took place over five years and four RCMs. A CRP on this subject was approved in early 2005. The objectives of this CRP are to: transfer know-how in the area of 99 Mo production using LEU targets based on reference technologies from leading laboratories in the field to the participating laboratories in the CRP; develop national work plans based on various stages of technical development and objectives in this field; establish the procedures and protocols to be employed, including quality control and assurance procedures; establish the coordinated activities and programme for preparation, irradiation, and processing of LEU targets [a]; and to compare results obtained in the implementation of the technique in order to provide follow up advice and assistance. Technetium-99m ( 99m Tc), the daughter product of molybdenum-99 ( 99 Mo), is the most commonly utilized medical radioisotope in the world, used for approximately 20-25 million medical diagnostic procedures annually, comprising some 80% of all diagnostic nuclear medicine procedures. National and international efforts are underway to shift the production of medical isotopes from highly enriched uranium (HEU) to low enriched uranium (LEU) targets. A small but growing amount of the current global 99 Mo production is derived from the irradiation of LEU targets. The IAEA became aware of the interest of a number of developing Member States that are seeking to become small scale, indigenous producers of 99 Mo to meet local nuclear medicine requirements. The IAEA initiated Coordinated Research Project (CRP) T.1.20.18 “Developing techniques for small-scale indigenous production of Mo-99 using LEU or neutron activation” in order to assist countries in this field. The more

  11. Present status of 99Mo/99mTc supply in Japan

    International Nuclear Information System (INIS)

    Yamashita, Takashi; Nakamura, Yoshihide

    2017-01-01

    The use of medical radioisotopes is an important part of modern medical practice. Disruptions in the radioisotope supply chain can disturb the availability of medical testing for millions of patients around the world. The NEA established the High-level Group on the Security of Supply of Medical Radioisotopes (HLG-MR) in 2009. During the 2009-2010 period, there were substantial shortages, but in the period since 2011 there have been only a limited number of minor supply shortages of the most widely used medical radioisotope. Japan does not have a reactor for 99 Mo production or a processing facility, and has been considering a number of alternative technology approaches to produce material domestically. (author)

  12. The LHC in numbers

    CERN Multimedia

    Alizée Dauvergne

    2010-01-01

    What makes the LHC the biggest particle accelerator in the world? Here are some of the numbers that characterise the LHC, and their equivalents in terms that are easier for us to imagine.   Feature Number Equivalent Circumference ~ 27 km   Distance covered by beam in 10 hours ~ 10 billion km a round trip to Neptune Number of times a single proton travels around the ring each second 11 245   Speed of protons first entering the LHC 299 732 500 m/s 99.9998 % of the speed of light Speed of protons when they collide 299 789 760 m/s 99.9999991 % of the speed of light Collision temperature ~ 1016 °C ove...

  13. 14 CFR 151.99 - Modifications of programming standards.

    Science.gov (United States)

    2010-01-01

    ... 14 Aeronautics and Space 3 2010-01-01 2010-01-01 false Modifications of programming standards. 151... (CONTINUED) AIRPORTS FEDERAL AID TO AIRPORTS Project Programming Standards § 151.99 Modifications of programming standards. The Director, Airports, Service, or the Regional Director concerned may, on individual...

  14. Accuracy of 99Molybdenum assays in /sup 99m/Technetium solutions

    International Nuclear Information System (INIS)

    Williams, C.C.; Kereiakes, J.G.; Grossman, L.W.

    1981-01-01

    A study was performed to determine the accuracy of 99 Mo measurements using three commercial dose calibrators with their 99 Mo assay shields. One 99 Mo assay shield allowed excessive penetration by the lower energy /sup 99m/Tc photons, resulting in the calibrator's falsely high interpretation of the activity of 99 Mo present in the high-activity /sup 99m/Tc eluates. All three calibrators performed adequately with a National Bureau of Standards 99 Mo standard in equilibrium with /sup 99m/Tc. By using low-activity aliquots of 99 Mo and /sup 99m/Tc, a low-level linearity test was performed. Only one of the calibrators was found to reflect accurately the activity of 99 Mo present under all conditions tested

  15. 14 CFR 119.47 - Maintaining a principal base of operations, main operations base, and main maintenance base...

    Science.gov (United States)

    2010-01-01

    ... 14 Aeronautics and Space 3 2010-01-01 2010-01-01 false Maintaining a principal base of operations, main operations base, and main maintenance base; change of address. 119.47 Section 119.47 Aeronautics... Under Part 121 or Part 135 of This Chapter § 119.47 Maintaining a principal base of operations, main...

  16. Triamide mercaptide (N/sub 3/S) ligands for Tc-99m as potential Tc-99m renal function agents

    International Nuclear Information System (INIS)

    Fritzberg, A.R.; Kasina, S.; Johnson, D.L.; Eshima, D.

    1985-01-01

    A number of diamide dimercaptide (N/sub 2/S/sub 2/) complexes of Tc-99m have shown potential as renal tubular function radiopharmaceuticals that could replace radioiodinated hippurate (OIH). Evaluation of such ligands suggested that maximum efficiency for tubular secretion and specificity resulted from addition of a carboxylate group. However, such derivatives resulted in chelate ring stereoisomers that were differently transported by the renal tubular system. The problem of stereoisomers was obviated by replacing one sulfur with an effectively planar amido nitrogen. Groups on the nitrogen then result in diastereomers only when an additional asymetric center is present. A series of triamide mercaptide compounds have been synthesized to evaluate this class as ligands for Tc-99m. One of the simplest of the series, mercaptoacetylglycylglycylglycine (MAG/sub 3/), formed a single Tc-99m product in high yield as determined by HPLC. Preliminary results with pmr and ms of the Tc-99 complex indicate a structure consistent with a 1:1 metal to ligand ratio and monooxo technetium group. Biological evaluation of Tc-99m MAG/sub 3/ showed high renal specificity and rate of excretion exceeding OIH in several species including humans. Members of the N/sub 3/S series studied include mercaptoacetylglycylglycyl-amino acids. In some cases with second asymmetric centers, two components were seen on HPLC. In mice several dianionic Tc-99m complexes were excreted faster than OIH, Tc-99m MAG/sub 2/-ala, -asn, and -gln. Trianionic Tc-99m MAG/sub 2/-asp and -glu were excreted more slowly, and Tc-99m MAG/sub 2/-phe showed hepatobiliary excretion. Triamide mercaptides represent a new ligand class for Tc-99m

  17. Numerical Study of a High Head Francis Turbine with Measurements from the Francis-99 Project

    International Nuclear Information System (INIS)

    Wallimann, H; Neubauer, R

    2015-01-01

    For the Francis-99 project initiated by the Norwegian University of Science and Technology (NTNU, Norway) and the Luleå University of Technology (LTU, Sweden) numerical flow simulation has been performed and the results compared to experimentally obtained data. The full machine including spiral casing, stay vanes, guide vanes, runner and draft tube was simulated transient for three operating points defined by the Francis-99 organisers. Two sets of results were created with differing time steps. Additionally, a reduced domain was simulated in a stationary manner to create a complete cut along constant prototype head and constant prototype discharge. The efficiency values and shape of the curves have been investigated and compared to the experimental data. Special attention has been given to rotor stator interaction (RSI). Signals from several probes and their counterpart in the simulation have been processed to evaluate the pressure fluctuations occurring due to the RSI. The direct comparison of the hydraulic efficiency obtained by the full machine simulation compared to the experimental data showed no improvement when using a 1° time step compared to a coarser 2° time step. At the BEP the 2° time step even showed a slightly better result with an absolute deviation 1.08% compared with 1.24% for the 1° time step. At the other two operating points the simulation results were practically identical but fell short of predicting the measured values. The RSI evaluation was done using the results of the 2° time step simulation, which proved to be an adequate setting to reproduce pressure signals with peaks at the correct frequencies. The simulation results showed the highest amplitudes in the vaneless space at the BEP operating point at a location different from the probe measurements available. This implies that not only the radial distance, but the shape of the vaneless space influences the RSI

  18. Quantifying Tc-99 contamination in a fuel fabrication plant - 59024

    International Nuclear Information System (INIS)

    Darbyshire, Carol; Burgess, Pete

    2012-01-01

    The Springfields facility manufactures nuclear fuel products for the UK's nuclear power stations and for international customers. Fuel manufacture is scheduled to continue into the future. In addition to fuel manufacture, Springfields is also undertaking decommissioning activities. Today it is run and operated by Springfields Fuels Limited, under the management of Westinghouse Electric UK Limited. The site has been operating since 1946 manufacturing nuclear fuel. As part of the decommissioning activities, there was a need was to quantify contamination in a large redundant building. This building had been used to process uranium derived from uranium ore concentrate but had also processed a limited quantity of recycled uranium. The major non-uranic contaminant was Tc-99. The aim was to be able to identify any areas where the bulk activity exceeded 0.4 Bq/g Tc-99 as this would preclude the demolition rubble being sent to the local disposal facility. The problems associated with this project were the presence of significant uranium contamination, the realisation that both the Tc-99 and the uranium had diffused into the brickwork to a significant depth and the relatively low beta energy of Tc-99. The uranium was accompanied by Pa-234m, an energetic beta emitter. The concentration/depth profile was determined for several areas on the plant for Tc-99 and for uranium. The radiochemical analysis was performed locally but the performance of the local laboratory was checked during the initial investigation by splitting samples three ways and having confirmation analyses performed by 2 other laboratories. The results showed surprisingly consistent concentration gradients for Tc-99 and for uranium across the samples. Using that information, the instrument response was calculated for Tc-99 using the observed diffusion gradient and averaged through the full 225 mm of brick wall, as agreed by the regulator. The Tc-99 and uranium contributions to the detector signal were separated

  19. Study of methodologies for quality control of 99Mo used in 99Mo/99mTc generators

    International Nuclear Information System (INIS)

    Said, Daphne de Souza

    2016-01-01

    99m Tc is the most used radionuclide in nuclear medicine. In Brazil, the 99 Mo/ 99m Tc generators are exclusively produced by Radiopharmacy Center at IPEN-CNEN/ SP, by importing 99 Mo from different suppliers. 99 Mo (t 1/2 = 66 h) is a fission product of 235 U and it can have radionuclidic impurities that are prejudicial for human health. For safe use of generators, it is necessary to perform the evaluation of 99 Mo by quality control tests in order to assess if 99 Mo complies with the specifications. The European Pharmacopoeia (EP) presents a monograph for evaluation of the quality of the [ 99 Mo] solution as sodium molybdate,that is used as raw material for 99 Mo/ 99m Tc generators production, including specification parameters (identification, radiochemical purity and radionuclidic purity), analysis methods and limits. However, it has been observed difficulties on the execution and implementation of these methods by the generators producers, with a few literature about this subject, probably due to complexity of the proposed methods. In this work, many quality control parameters of 99 Mo described in the EP monograph were evaluated. Separation methods for 99M o from its radionuclidic impurities by solid phase extraction (SPE) and TLC were studied. After SPE separation, the quantification of metals by ICP-OES to evaluate the percentage of retention of Mo and the percentage of recovery of Ru, Te and Sr using different types of cartridges were proposed, replacing radiotracers use. It was observed that the specific type of SPE cartridge recommended by the EP for separation of 99 Mo presented low recoveries for Ru, compared to other available anion exchange SPE cartridges. 99 Mo samples from different worldwide suppliers were analyzed. It was observed that quantification of 103 Ru in 99 Mo samples with decay time higher than 4 weeks is possible. An alternative method for separation of 131 I from 99 Mo showed promising results by TLC. The quantification of beta and

  20. Radiation damage to mouse testis cells from [/sup 99m/Tc] pertechnetate

    International Nuclear Information System (INIS)

    Mian, T.A.; Suzuki, N.; Glenn, H.J.; Haynie, T.P.; Meistrich, M.L.

    1977-01-01

    The radiation dose and the biologic damage to mouse testis from intravenously administered [/sup 99m/Tc] pertechnetate were studied. The dose was measured for penetrating radiations from /sup 99m/Tc, using calibrated thermoluminescent dosimeters and calculations from the uptake of the nuclide in the testis, and was found to be 4.9 rads per mCi of 99 Tc. The biologic damage was measured by the decrease in the number of sperm heads in the testis, counted both by hemacytometer and by Coulter counter. In preliminary experiments using external gamma radiation from 137 Cs, the number of sperm heads reached a minimum 29 days after irradiation. Twenty-nine days after injection of 5.8 mCi of /sup 99m/Tc, which gives 28 rads to the testis, the number of sperm heads decreased to 70% of control. The biologic effect corresponds to that seen after 40 rads of gamma radiation from 137 Cs. The damage to mouse testis cells from internally administered /sup 99m/Tc as measured in an in vivo system appears to be at least as significant as that from external gamma irradiation, if not more so

  1. Current status of production and supply of molybdenum-99 and 99Mo/99mTc generators in Indonesia

    International Nuclear Information System (INIS)

    Mutalib, A.

    2003-01-01

    Production of high-specific activity molybdenum-99 and 99 Mo/ 99m Tc Generators in Indonesia commenced when a new production facility supported by the presence of a 30 MW multipurpose reactor (RSG-GAS) was established in Serpong in 1990. This report describes the current production and supply of molybdenum-99m devoted mainly to fulfill the domestic demands in supplying 99 Mo/ 99m Tc Generators. Recent development on the use of LEU (Low Enriched Uranium) targets for replacing current HEU (High Enriched Uranium) targets in the production of 99 Mo will be reviewed briefly. (author)

  2. Measurement of Mo-99 column activity in the evaluation of Mo-99/Tc-99m generator

    International Nuclear Information System (INIS)

    Kuster, Z.

    1994-01-01

    In order to calculate the real elution efficiency of Mo-99/Tc-99m generator the Mo-99 content on the column has to be previously determined. As found in this work, the external measurement of Mo-99-column activity by means of Geiger-Mueller counter is a simple, fast and reliable method. Generally, Mo-99-column is placed slightly out of the center of the generator; therefore the externally measured flux of photons (φ) is an angular-dependent function. If the thickness of the lead container is radially uniform, the flux measured at some distance from the generator (which is rotated in 2π/3 steps) is given by the equation φ = A (1 + Bcos (α-2π(i - 2)/3)) -1 , i=1,2 or 3 (Eq.1) where A is a numerical constant depending on the Mo-99-column activity, B is a numerical constant depending on the Mo-99- column position within the lead container, the angle α depends on the initial orientation of the generator. A total of 20 generator were studied. The measured Mo-99-column activities (Capintec dose calibrator) were in the range 13.1- 35.11 GBq. Contrary to the findings of Vinberg and Kristensen (Eur J Nucl Med 1/1976(219), values of A (Eq. 1) are in good correlation (r 2 =0.9794) with the measured Mo-99-column activities. (author)

  3. Comparison of 99mTc-HYNIC-TOC and HYNIC-TATE octreotide scintigraphy with FDG PET and 99mTc-MIBI in local recurrent or distant metastatic thyroid cancers.

    Science.gov (United States)

    Sager, Sait; Kabasakal, Levent; Halac, Metin; Maecke, Helmut; Uslu, Lebriz; Önsel, Çetin; Kanmaz, Bedii

    2013-05-01

    There have been various studies for early diagnosis of local recurrent or distant metastatic thyroid cancers. The aim of this study is to evaluate the clinical utility of 99mTc-HYNIC-TOC and 99mTc-HYNIC-TATE, octreotide derivatives, to detect recurrences or distant metastases in 131I-negative thyroglobulin positive thyroid cancer patients and to compare the lesions with FDG PET and 99mTc-MIBI studies in the same patient group. Twenty differentiated thyroid cancer patients, 7 male and 13 female, mean age 54.6 ± 15.3 (range 13-78 years), were included in this study. Eighteen patients had papillary thyroid cancer and 2 had follicular thyroid cancer. Fifteen patients received HYNIC-TOC and 5 patients received HYNIC-TATE as a radiopharmaceutical. All patients underwent whole-body scan 1 and 4 hours after injection of octreotide derivatives and SPECT imagings were performed from the suspicious sites. The lesions that were seen in 99mTc-HYNIC-TOC and 99mTc-HYNIC-TATE studies were compared with 99mTc-MIBI and FDG-PET studies. Among 99mTc-HYNIC-TOC and 99mTc-HYNIC-TATE scintigraphies, 15 patient studies were evaluated as true positive (75%) and 5 were false negative (25%). The total number of lesions in octreotide scintigraphy was 48 in 20 patients. Of 20 patients, 19 had FDG-PET study, 15 of them were evaluated as true positive (78.9%), and 4 them were evaluated as false negative (21.1%). Total number of lesions in FDG PET was 74. 99mTc-MIBI study was positive in 11 patients (55%) and negative in 9 patients (45%). Total number of lesions in 99mTc-MIBI was 25. Technetium-labeled somatostatin receptor scintigraphy analogues HYNIC-TOC and HYNIC-TATE are useful imaging alternatives in somatostatin receptor expressing thyroid cancer patients. Radiolabeling is easy and they are readily available for routine use.

  4. Determination of technetium-99 in environmental samples: A review

    DEFF Research Database (Denmark)

    Shi, Keliang; Hou, Xiaolin; Roos, Per

    2012-01-01

    Due to the lack of a stable technetium isotope, and the high mobility and long half-life, 99Tc is considered to be one of the most important radionuclides in safety assessment of environmental radioactivity as well as nuclear waste management. 99Tc is also an important tracer for oceanographic...... research due to the high technetium solubility in seawater as TcO4−. A number of analytical methods, using chemical separation combined with radiometric and mass spectrometric measurement techniques, have been developed over the past decades for determination of 99Tc in different environmental samples....... This article summarizes and compares recently reported chemical separation procedures and measurement methods for determination of 99Tc. Due to the extremely low concentration of 99Tc in environmental samples, the sample preparation, pre-concentration, chemical separation and purification for removal...

  5. A new anti-glioma therapy, AG119: pre-clinical assessment in a mouse GL261 glioma model

    International Nuclear Information System (INIS)

    Towner, Rheal A.; Ihnat, Michael; Saunders, Debra; Bastian, Anja; Smith, Nataliya; Pavana, Roheeth Kumar; Gangjee, Aleem

    2015-01-01

    High grade gliomas (HGGs; grades III and IV) are the most common primary brain tumors in adults, and their malignant nature ranks them fourth in incidence of cancer death. Standard treatment for glioblastomas (GBM), involving surgical resection followed by radiation and chemotherapy with temozolomide (TMZ) and the anti-angiogenic therapy bevacizumab, have not substantially improved overall survival. New therapeutic agents are desperately needed for this devastating disease. Here we study the potential therapeutic agent AG119 in a pre-clinical model for gliomas. AG119 possesses both anti-angiogenic (RTK inhibition) and antimicrotubule cytotoxic activity in a single molecule. GL261 glioma-bearing mice were either treated with AG119, anti-VEGF (vascular endothelial growth factor) antibody, anti c-Met antibody or TMZ, and compared to untreated tumor-bearing mice. Animal survival was assessed, and tumor volumes and vascular alterations were monitored with morphological magnetic resonance imaging (MRI) and perfusion-weighted imaging, respectively. Percent survival of GL261 HGG-bearing mice treated with AG119 was significantly higher (p < 0.001) compared to untreated tumors. Tumor volumes (21–31 days following intracerebral implantation of GL261 cells) were found to be significantly lower for AG119 (p < 0.001), anti-VEGF (p < 0.05) and anti-c-Met (p < 0.001) antibody treatments, and TMZ-treated (p < 0.05) mice, compared to untreated controls. Perfusion data indicated that both AG119 and TMZ were able to reduce the effect of decreasing perfusion rates significantly (p < 0.05 for both), when compared to untreated tumors. It was also found that IC 50 values for AG119 were much lower than those for TMZ in T98G and U251 cells. These data support further exploration of the anticancer activity AG119 in HGG, as this compound was able to increase animal survival and decrease tumor volumes in a mouse GL261 glioma model, and that AG119 is also not subject to methyl guanine

  6. 49 CFR 571.119 - Standard No. 119; New pneumatic tires for motor vehicles with a GVWR of more than 4,536 kilograms...

    Science.gov (United States)

    2010-10-01

    ... without interruption. (e) Immediately after running the tire the required time, measure the tire inflation...) Immediately after running the tire the required time, measure the tire inflation pressure. Remove the tire... 49 Transportation 6 2010-10-01 2010-10-01 false Standard No. 119; New pneumatic tires for motor...

  7. The Supply of Medical Radioisotopes. Medical Isotope Supply in the Future: Production Capacity and Demand. Forecast for the 99Mo/99mTc Market, 2015-2020

    International Nuclear Information System (INIS)

    Peykov, Pavel; Cameron, Ron

    2014-04-01

    This document presents a forecast of 99 Mo/ 99m Tc production capacity and demand in 2015-2020, when two major irradiators - the OSIRIS and NRU reactors in France and Canada - are expected to exit the global supply chain and new alternative technology projects may be commissioned. The forecast does not attempt to predict shortages, but identify periods when there is an increased risk of disrupted supply, to inform policy makers and other stakeholders. (authors)

  8. Chloride – a precursor in the formation of volatile organochlorines by forest plants?

    Czech Academy of Sciences Publication Activity Database

    Laturnus, F.; Matucha, Miroslav

    2008-01-01

    Roč. 99, č. 1 (2008), s. 119-125 ISSN 0265-931X R&D Projects: GA ČR GA526/05/0636 Institutional research plan: CEZ:AV0Z50380511 Keywords : 36Chloride * Volatile Organochlorines * VOCl Subject RIV: DF - Soil Science Impact factor: 1.114, year: 2008

  9. Relationship of 99mTc-HYNIC annexin V uptake to microvessel density, FasL and MMP-9 expression, and the number of tumour-infiltrating lymphocytes in head and neck carcinoma

    International Nuclear Information System (INIS)

    Vermeersch, Hubert; Loose, David; Mervillie, Kris; Cuvelier, Claude; Lahorte, Christophe; Slegers, Guido; Dierck, Rudi Andre; Van de Wiele, Christophe; Steinmetz, Neil

    2004-01-01

    This study reports on the relationship between quantitative 99m Tc-HYNIC radiolabelled annexin V tumour uptake measurements, Fas ligand (FasL) expression, matrix metalloproteinase-9 (MMP-9) expression, microvessel density (MVD) and the number of tumour-infiltrating lymphocytes in squamous cell carcinoma of the head and neck (SCCHN) patients. Twenty-eight patients (24 men and 4 women; mean age 59 years, range 43-83 years) suffering from a primary (n, number of patients=22) or locally recurrent (n=6) SCCHN were studied. All patients underwent a spiral CT scan, allowing estimation of lesion size in three dimensions, and 99m Tc-HYNIC annexin V scintigraphy within 1 week of each other. Biopsies or resection of the suspected primary tumour or local recurrence for histopathological analysis were performed on all patients within a period of 10 days following 99m Tc-HYNIC annexin V scintigraphy. The percentage uptake of the injected dose of 99m Tc-HYNIC annexin V in visible tumour lesions on scintigrams divided by the tumour volume, derived from CT, was related to MVD and to histological score (HSCORE) values for MMP-9 and FasL expression as well as to the number of tumour-infiltrating lymphocytes (CD45 staining). Median percentage absolute tumour uptake of the injected dose/cm 3 tumour volume derived from tomographic images was 0.0001% (SD 0.0001%) at 5-6 h p.i. (range: 0.000007-0.0003%). Mean HSCORE for MMP-9 tumour staining was 2.1 (SD 0.84). Mean HSCORE for FasL tumour staining was 2.49 (SD 0.92). At the sites of tumour containing the highest number of vessels, the mean MVD was 20 vessels/field at the hot spot (range 1-73). The median number of tumour-infiltrating lymphocytes was 500 (range 100-5,000). The percentage absolute tumour uptake of the injected dose/cm 3 tumour volume derived from tomographic images correlated linearly with FasL HSCORES(r=0.47, P=0.02). No correlation was found between the percentage absolute tumour uptake of the injected dose/cm 3 tumour

  10. Study on decay of 118Xe and 119Xe by means of mass-separator on-line with a synchrocyclotron

    International Nuclear Information System (INIS)

    Berlovich, Eh.E.; Batist, L.Kh.; Blinnikov, Yu.S.

    1976-01-01

    The decay of sup(118, 119)Xe isotopes has been investigated. An experimental device involving a mass-separator operating in line with a synchrocyclotron is briefly outlined. The elements to be investigated were isolated from a proton-irradiated target by the 'on-beam-chemistry' methods and transferred into the mass-separator ion source. The Xe separated ions are transported to detectors in an experimental ha ll. The energies and relative γ ray intensities of 118 Xe → 118 J and of 119 Xe → 119 J decays ar presented. The error of the γ ray energy determination does not exceed 0.6 keV. Obtained are the periods of half-life: for 118 Xe - (3.8+-0.9) min, for 119 Xe - (5.8+-0.3) min. The decay scheme for 119 Xe is made up. The scheme of 119 Xe levels is well inscribed into the general systematics of the J odd isotope levels. On the basis of obtained and known data the spin values are described to the 119 J levels

  11. Quality assurance of Mo-99/Tc-99m radionuclide generators

    Science.gov (United States)

    Uzunov, Nikolay; Yordanova, Galina; Salim, Seniha; Stancheva, Natalya; Mineva, Vanya; Meléndez-Alafort, Laura; Rosato, Antonio

    2018-03-01

    Gamma-ray spectrometry analyses of the radionuclide content of eluate from two Mo-99/Tc-99m radionuclide generators POLTECHNET have been performed. The relative activities of 99Mo 103Ru and 131I radioisotopes with respect to the activity of 99mTc at different time intervals after the primary pertechnetate elution of the generators have been analyzed. The relative activities of the isotopes were determined and compared to the radionuclidic purity requirements for 99mTc.

  12. Characterization of phenols from coal liquefaction products by 119Sn nuclear magnetic resonance spectrometry

    International Nuclear Information System (INIS)

    Rafii, E.; Faure, R.; Lena, L.; Vincent, E.J.; Metzger, J.

    1985-01-01

    The 119 Sn NMR chemical shifts for tri-n-butyltin derivatives of 33 phenols commonly found in coal-derived liquids are reported. Analysis of coal-derived phenol fractions by this methods is comparatively straightforward and quantitative. Chemical shift ranges of phenol derivatives by various NMR methods and the present one using 119 Sn NMR are compared. 32 references, 4 figures, 4 tables

  13. Molybdenum-99/technetium-99M generators

    International Nuclear Information System (INIS)

    Morcos, N.A.; Bruno, G.A.; Haney, T.A.

    1981-01-01

    A 99 Mo/sup(99m)Tc generator is described which has an alumina support medium consisting of multiple beds of controlled pH and in which no bed has a pH value higher than the bed preceding it. It is claimed that by using this method low yield problems of such generators can be mitigated. (U.K.)

  14. Simultaneous projection of particle-number and angular momentum BCS wave-functions in the rare-earth nuclei

    International Nuclear Information System (INIS)

    Oudih, M.R.; Fellah, M.; Allal, N.H.; Benhamouda, N.

    1999-01-01

    It is well established that the BCS wave-functions are neither eigen-functions of the particle-number operator nor of the angular momentum operator. In a previous paper, we have developed a particle-number projection before variation method (of FBCS type). This discrete projection method is based on the SBCS wave-function. The aim of the present contribution is to perform a subsequent angular momentum projection by means of the Peierls-Yoccoz method. The general expression of the system energy, after the double projection, is established in the case of axial symmetry. For practical calculations, an approximation method is introduced. It leads to a semi-classical form of the rotational energy. The rotational spectra have been evaluated numerically for some even-even rare-earth nuclei. The single-particle energies and eigen-states are those of a deformed Woods-Saxon mean field. The obtained results are compared on one hand, to the experimental data, and on the other hand, to the theoretical spectra evaluated by a particle-number projection after variation method (of PBCS type). For all studied nuclei, the spectra determined by the FBCS method reproduce the experimental data better than those of the PBCS method. However, even if the present method is satisfying for low angular momenta, the agreement with the experimental data is lesser for I ≥ 8, particularly for the lighter studied nuclei. (authors)

  15. Accumulation of 99Tcm MDP in lung cancer of 84 patients

    International Nuclear Information System (INIS)

    Yang, Y.S.F.; Zeng, Z.J.; Shao, S.J.L.; Shi, S.M.P.; Zheng, Z.Z.C.

    2002-01-01

    Objective: To analyze the clinic mechanisms of technetium-99m-methyl-diphosphate ( 99 Tc m -MDP) uptake in lung cancer. Methods: 84 patients (63 men, 21 women; mean age 61.56 years) with lung cancer and no effusion underwent bone scan. Of 84, there were primary lung cancer in 63 cases and metastatic lung cancer in 21 cases. 28 adenocarcinomas, 32 squamous carcinomas, 9 adenosquamous carcinomas, 9 non-classified non-small cell lung cancers, 6 small cell lung carcinomas. Final diagnoses were established by histology in all patients. The bone scan was performed 3-8h after i.v. injection of 1295MBq 99 Tc m -MDP. The whole body scan was performed using a SPET camera (MULTISPECT2, Siemans) and the scan speed was 11cm/min. Tracer uptake was visual and semi-quantitative analyzed for each patient. The expression of 99 Tc m -MDP uptake in lung was determined the intensity and then took semi-quantitative analysis of 99 Tc m -MDP uptake, regions of interest (RIOs) placed on the lesions encompassed all pixels and horizontal copied to normal lung in anterior and posterior view, and the average count ratio (tumor to normal lung T/N) in each ROI was calculated. We analyzed the ratio by computing the standardized uptake measures (SUMs) to determine the tumor-positive value (T/N) greater than or equal to 1.2. All 99 Tc m -MDP images were carefully compared with their contemporaneous chest roentgenograms, CT and histopathology studies. Results: For statistics analysis of the 99 Tc m -MDP uptake in lung cancer, the men were 81% in 63 cases, women 19% in 21; the age of less than or equal to fifty years old is 12% in 10; poorly differentiated carcinoma was 48.8% in 41, med-differentiated carcinoma was 39.3% in 33 and differentiated was 11.9% in 10;the patients of chemotherapy were 32.1% in 27; the metastatic lymph nodules were 51.2% in 43; the diameter of tumor with larger than 5 cm was 72.4% in 60;pleura involvement was 83.7% in 36; necrosis was 76.8% in 33; abnormality of enzyme (GPT

  16. Generators of 99Mo-99mTc

    International Nuclear Information System (INIS)

    Robles, A.M.

    1994-01-01

    Between the radioisotopes family pairs we find the 99 Molibdenum - 99m technetium pairs. Such as isotope production,decay and chemical toxic, humid and dry generators,radiation protection handling practice and blinding had been sudied in this work.Tabs

  17. CD 4 + CD 25 + T cells maintain homeostasis by promoting TER - 119 cell development and inhibiting T cell activation

    Directory of Open Access Journals (Sweden)

    Muhaimin Rifa’i

    2014-05-01

    Full Text Available CD4+ CD25+ regulatory T cells involved in the regulation of self- tolerance and normality of homeostasis. CD122 deficient mice are model animals that have an abnormal immune system characteristically have a high number of activated T cells and TER-119 cell decreased. Here we showed evidence that the transfer of CD4+ CD25+ regulatory T cells derived from normal mice to CD122- defficient neonates prevent the development of activated memory T cells and elicit TER-119 differentiation. Bone marrow reconstitution derived from CD122-/- mice to normal mice resulting tolerance to individual that genetically different. Importantly, CD4+ CD25+ regulatory T cells derived from normal mice can replace CD4+ CD25+ cells derived from CD122-/- mice. The results of this experiment suggest that regulatory T cells from normal mice exert a critical role in maintaining peripheral tolerance and controlling hematopoietic disorder.

  18. Development of 99Mo/99mTc Generator System for Production of Medical Radionuclide 99mTc using a Neutron-activated 99Mo and Zirconium Based Material (ZBM as its Adsorbent

    Directory of Open Access Journals (Sweden)

    I. Saptiama

    2016-12-01

    Full Text Available Molybdenum produced from fission of U-235 is the most desirable precursor for 99Mo/99mTc generator system as it is non-carrier added and has high specific activity. However, in the last decade there has been short supply of 99Mo due to several constrains. Therefore, there have been many works performed for development of 99Mo/99mTc generator system using 99Mo which is not produced from either LEU or HEU. This report deals with development of 99Mo/99mTc generator system where zirconium-based material (ZBM is used as adsorbent of neutron-activated 99Mo. The system was prepared by firstly irradiating natural Mo in the G. A. Siwabessy reactor to produce neutron-activated 99Mo. The target was dissolved in NaOH 4N and then neutralized with 12 M HCl. The 99Mo solution was then mixed with a certain amount of ZBM followed by heating at 90°C for three hours to allow the 99Mo adsorbed on ZBM. The 99Mo-ZBM (9.36 GBq of 99Mo was Mo/ 4.2 g ZBM was packed on a fritz-glass column. This column was then fitted serially with an alumina column for trapping 99Mo breakthrough. The columns were then eluted daily with saline solution for up to one week. The yield of 99mTc was found to be between 53.7 – 74% (n= 5. All 99mTc eluates were clear solutions with pH of 5. Breakthrough of 99Mo in 99mTc eluates was found to be 0.031 ± 0.019 μCi 99Mo/ mCi 99mTc (n= 5 which was less than the maximum activity of 99Mo allowed in 99mTc solution ( 99%. Radiolabeling of this 99mTc towards methylene diphosphonate (MDP kit gave a radiolabelling efficiency of 99%. In summary, a new 99Mo/99mTc generator system that used neutron-activated 99Mo and ZBM as its adsorbent has been successfully prepared. The 99mTc produced from this new 99Mo/99mTc generator system attained the quality of 99mTc required for medical purposes.

  19. Nature of the 153 and 270 keV transitions in /sup 119/Sb from sup(119m)Te

    Energy Technology Data Exchange (ETDEWEB)

    Sahota, H S [Punjabi Univ., Patiala (India). Dept. of Physics

    1982-08-01

    The 153 and 270 keV transitions in /sup 119/Sb have been investigated for the presence of any anomalous conversion through conversion electron intensity and conversion-electron gamma and gamma-gamma directional correlation measurements. The resulting subshell ratios and particle rarameters have been analysed for the accurate determination of mixing ratios for the transitions. The results are delta/sub 153/ = +-0.0025 and delta/sub 270/ = 0.10 sub(-0.20)sup(+0.03). The conversion process has been found to be normal in both cases.

  20. A new anti-glioma therapy, AG119: pre-clinical assessment in a mouse GL261 glioma model.

    Science.gov (United States)

    Towner, Rheal A; Ihnat, Michael; Saunders, Debra; Bastian, Anja; Smith, Nataliya; Pavana, Roheeth Kumar; Gangjee, Aleem

    2015-07-17

    High grade gliomas (HGGs; grades III and IV) are the most common primary brain tumors in adults, and their malignant nature ranks them fourth in incidence of cancer death. Standard treatment for glioblastomas (GBM), involving surgical resection followed by radiation and chemotherapy with temozolomide (TMZ) and the anti-angiogenic therapy bevacizumab, have not substantially improved overall survival. New therapeutic agents are desperately needed for this devastating disease. Here we study the potential therapeutic agent AG119 in a pre-clinical model for gliomas. AG119 possesses both anti-angiogenic (RTK inhibition) and antimicrotubule cytotoxic activity in a single molecule. GL261 glioma-bearing mice were either treated with AG119, anti-VEGF (vascular endothelial growth factor) antibody, anti c-Met antibody or TMZ, and compared to untreated tumor-bearing mice. Animal survival was assessed, and tumor volumes and vascular alterations were monitored with morphological magnetic resonance imaging (MRI) and perfusion-weighted imaging, respectively. Percent survival of GL261 HGG-bearing mice treated with AG119 was significantly higher (p mouse GL261 glioma model, and that AG119 is also not subject to methyl guanine transferase (MGMT) mediated resistance, as is the case with TMZ, indicating that AG119 may be potentially useful in treating resistant gliomas.

  1. An unusual accumulation of technetium-99m-sestamibi (99mTc-MIBI) mimicking an ectopic hyperfunctioning parathyroid tissue: usefulness of CT/SPECT technology in a single device

    International Nuclear Information System (INIS)

    Kienast, O.; Traub, T.; Dobrozemsky, G.; Dudczak, R.; Kurtaran, A.; Kletzmayr, J.; Kainberger, F.

    2002-01-01

    Full text: 99mTc-MIBI dual phase scintigraphy is a well established imaging modality in detecting hyperfunctioning parathyroid tissue. The authors report a case of 99mTc-MIBI scintigraphy showing MIBI-accumulation in projection of the upper mediastinum suspicious for hyperfunctioning parathyroid tissue. Further anatomical localization achieved by combined CT/SPECT technology revealed no mediastinal mass. A 71-year-old man with renal transplantation following chronic renal failure experienced hypercalcemia, hyperphosphatemia and elevation of serum parathyroid hormone levels. Ultrasonography of the neck revealed no enlarged parathyroid glands and further diagnostic work-up has been performed. A 99mTc-MIBI dual phase scintigraphy showed no abnormal accumulation in the typical parathyroid region but a focal activity in projection of the upper mediastinum was detected. The SPECT imaging of the neck and upper chest showed the accumulation in anterior location. This finding was interpreted as an ectopic (mediastinal) hyperfunctioning parathyroid tissue. In order to localize the focus, a CT/SPECT study with a single device system (GE Medical Systems Millennium VG gamma camera with Hawkeye) was done. This is an imaging system composed of a low current x-ray tube and a set of detectors mounted onto the camera's slip ring gantry. On registered and fused anatomical/functional images (CT/99mTc-MIBI SPECT), the increased accumulation of 99mTc-MIBI was shown to be an accumulation in the upper sternum. Further radiological examination revealed no abnormality in the sternum. This case illustrates the usefulness of the combined CT/SPECT imaging strategy with a single device in preventing unnecessary diagnostic/therapeutic interventions in patients with hyperthyroidism and abnormal 99mTc-MIBI scintigraphy. (author)

  2. Whole genome sequence of Enterobacter ludwigii type strain EN-119T, isolated from clinical specimens.

    Science.gov (United States)

    Li, Gengmi; Hu, Zonghai; Zeng, Ping; Zhu, Bing; Wu, Lijuan

    2015-04-01

    Enterobacter ludwigii strain EN-119(T) is the type strain of E. ludwigii, which belongs to the E. cloacae complex (Ecc). This strain was first reported and nominated in 2005 and later been found in many hospitals. In this paper, the whole genome sequencing of this strain was carried out. The total genome size of EN-119(T) is 4952,770 bp with 4578 coding sequences, 88 tRNAs and 10 rRNAs. The genome sequence of EN-119(T) is the first whole genome sequence of E. ludwigii, which will further our understanding of Ecc. © FEMS 2015. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  3. 34 CFR 300.119 - Technical assistance and training activities.

    Science.gov (United States)

    2010-07-01

    ... 34 Education 2 2010-07-01 2010-07-01 false Technical assistance and training activities. 300.119... Technical assistance and training activities. Each SEA must carry out activities to ensure that teachers and....114; and (b) Are provided with technical assistance and training necessary to assist them in this...

  4. The new 99mTc myocardial perfusion imaging agents: 99mTc-sestamibi and 99mTc-teboroxime

    International Nuclear Information System (INIS)

    Berman, D.S.; Kiat, H.; Maddahi, J.

    1991-01-01

    The two new 99m (99mTc) labeled myocardial perfusion agents, 99mTc-Sestamibi and 99mTc-Teboroxime, are now available for routine clinical application. Both agents allow assessment of ejection fraction by the first-pass technique at rest or during exercise, thus providing additional information not available with thallium-201. 99mTc-Sestamibi has long myocardial residence time, as well as adequate myocardial extraction, providing images of higher count density and superior quality compared with thallium-201. 99mTc-Teboroxime has excellent myocardial uptake characteristics but is cleared very rapidly from the myocardium. Both tracers have shown results similar to those obtained with thallium-201 for detection of coronary artery disease and the assessment of defect reversibility. 99mTc-Sestamibi studies using the rest/stress imaging sequence can be accomplished in approximately 5 hours; studies using dual-isotope imaging (rest thallium-201 and stress 99mTc-Sestamibi injection) can be completed in 1 to 2 hours. Gated stress images can be performed with 99mTc-Sestamibi, providing simultaneous information of myocardial perfusion at stress and resting wall motion or thickening and allowing rapid differentiation of ischemic from infarcted tissue. Because of its slow myocardial clearance and absence of redistribution, 99mTc-Sestamibi allows uncoupling of the time of injection from the time of imaging and thus can be valuable in the evaluation of acute myocardial infarction and outcome of thrombolytic therapy. With 99mTc-Teboroxime, rapid serial studies are feasible. Pharmacologic stress and rest studies with 99mTc-Teboroxime single photon emission computed tomography potentially can be completed in under 30 minutes. 73 references

  5. Phenotype, Immunological Reactivity and Cytokine Production Profile of Peyer`s Patch Cells from Mice Immunized Orally with Allogeneic Cells

    Czech Academy of Sciences Publication Activity Database

    Frič, Jan; Krulová, Magdalena; Zajícová, Alena; Holáň, Vladimír

    2000-01-01

    Roč. 46, č. 3 (2000), s. 119-125 ISSN 0015-5500 R&D Projects: GA ČR GA310/99/0360; GA ČR GA310/97/1261; GA ČR GA310/99/D044; GA MZd IZ3964; GA MŠk VS97099; GA MŠk ME 300 Grant - others:NATO(BE) CRG.LG972853 Institutional research plan: CEZ:AV0Z5052915 Subject RIV: EB - Genetics ; Molecular Biology Impact factor: 0.351, year: 2000

  6. Structural basis for constitutive activity and agonist-induced activation of the enteroendocrine fat sensor GPR119

    DEFF Research Database (Denmark)

    Engelstoft, Maja Storm; Norn, C; Pedersen, Maria Hauge

    2014-01-01

    BACKGROUND AND PURPOSE: GPR119 is a Gαs-coupled 7TM receptor activated by endogenous lipids such as oleoylethanolamide (OEA) and by the dietary triglyceride metabolite 2-monoacylglycerol. GPR119 stimulates enteroendocrine hormone and insulin secretion. But despite massive drug discovery efforts...... activation (AR231453 and OEA). Novel Rosetta-based receptor modelling was applied, using a composite template approach with segments from different X-ray structures and fully flexible ligand docking. KEY RESULTS: The increased signalling induced by increasing the cell surface expression of GPR119...... in the absence of agonist and the inhibitory effect of two synthetic inverse agonists demonstrated that GRP119 signals with a high degree of constitutive activity through the Gαs pathway. The mutational maps for AR231453 and OEA were very similar and, surprisingly, also similar to the mutational map for residues...

  7. Three-dimensional display of 99mTc-MIBI myocardial scintigraphy

    International Nuclear Information System (INIS)

    Kashimada, Akio; Machida, Kikuo; Honda, Norinari

    1992-01-01

    One of 99m Tc-hexakis, 99m Tc-methoxyisobutyl isonitrile (MIBI), has been demonstrated to have a myocardial uptake proportional to regional coronary blood flow. In this study, 99m Tc-MIBI myocardial scintigraphy was performed for 16 patients with ischemic heart disease. After injection of 740 MBq of 99m Tc-MIBI, 64 projection images were collected during a 360-degree rotation. Three-dimensional (3D) display of the left ventricle was reconstructed with depth-shading method from 99m Tc-MIBI SPECT images, which were reconstructed by filtered back projection method. In 9 of the patients, left ventricular cineangiography were performed as diagnostic gold standard. Four physicians blinded to patients' clinical information interpreted 3D images and SPECT images on separate occasions. Diagnosis of hypoperfusion by 3D displays agreed with those of SPECT in 92.9% (104/112 segments), and disagreed in 7.1% (8 segments). Sensitivity and specificity of 3D images were 87.0% and 93.9%, which were not statistically different (p<0.05) from that of SPECT images (91.3%, 97.0%). Receiver operating characteristic (ROC) analysis revealed nearly identical curves for the two. Although 3D display had nearly identical diagnostic ability with SPECT, observers reported that 3D images were easier to diagnose than SPECT images. An advantage of the 3D display is that the display gives a more realistic impression of the left ventricle to an observer than tomography or planar imaging. Another advantage is that 3D display can reduce the amount of data storage compared with that of SPECT. In conclusion, 3D images may be useful for diagnosis of hypoperfusion of left ventricle. (author)

  8. 99Mo-99mTc production development by (n, γ) reaction

    International Nuclear Information System (INIS)

    Izumo, Hironobu; Nishikata, Kaori; Kimura, Akihiro; Tanimoto, Masataka; Tsuchiya, Kunihiko; Ishihara, Masahiro; Kaminaga, Masanori

    2012-01-01

    The renewed JMTR will be started from the later half of JFY2012, and it is expected to various fields. Supply of 99 Mo in Japan depends only on imports from foreign countries. JAEA has a plan to produce 99 Mo, a parent nuclide of 99m Tc. JMTR will contribute to produce 99 Mo by (n, r) method as one of effective uses of the JMTR. In this paper, outline of the technical study items for production method of 99 Mo- 99m Tc in JMTR will be described. (author)

  9. Relationship of {sup 99m}Tc-HYNIC annexin V uptake to microvessel density, FasL and MMP-9 expression, and the number of tumour-infiltrating lymphocytes in head and neck carcinoma

    Energy Technology Data Exchange (ETDEWEB)

    Vermeersch, Hubert; Loose, David [Department of Head and Neck Surgery, University Hospital Ghent (Belgium); Mervillie, Kris; Cuvelier, Claude [Department of Pathology, University Hospital Ghent (Belgium); Lahorte, Christophe; Slegers, Guido [Department of Radiopharmacy, Ghent University (Belgium); Dierck, Rudi Andre; Van de Wiele, Christophe [Division of Nuclear Medicine, University Hospital Ghent, De Pintelaan 185B, 9000, Ghent (Belgium); Steinmetz, Neil [Theseus Imaging Corporation, Cambridge, Massachusetts (United States)

    2004-07-01

    This study reports on the relationship between quantitative {sup 99m}Tc-HYNIC radiolabelled annexin V tumour uptake measurements, Fas ligand (FasL) expression, matrix metalloproteinase-9 (MMP-9) expression, microvessel density (MVD) and the number of tumour-infiltrating lymphocytes in squamous cell carcinoma of the head and neck (SCCHN) patients. Twenty-eight patients (24 men and 4 women; mean age 59 years, range 43-83 years) suffering from a primary (n, number of patients=22) or locally recurrent (n=6) SCCHN were studied. All patients underwent a spiral CT scan, allowing estimation of lesion size in three dimensions, and {sup 99m}Tc-HYNIC annexin V scintigraphy within 1 week of each other. Biopsies or resection of the suspected primary tumour or local recurrence for histopathological analysis were performed on all patients within a period of 10 days following {sup 99m}Tc-HYNIC annexin V scintigraphy. The percentage uptake of the injected dose of {sup 99m}Tc-HYNIC annexin V in visible tumour lesions on scintigrams divided by the tumour volume, derived from CT, was related to MVD and to histological score (HSCORE) values for MMP-9 and FasL expression as well as to the number of tumour-infiltrating lymphocytes (CD45 staining). Median percentage absolute tumour uptake of the injected dose/cm{sup 3} tumour volume derived from tomographic images was 0.0001% (SD 0.0001%) at 5-6 h p.i. (range: 0.000007-0.0003%). Mean HSCORE for MMP-9 tumour staining was 2.1 (SD 0.84). Mean HSCORE for FasL tumour staining was 2.49 (SD 0.92). At the sites of tumour containing the highest number of vessels, the mean MVD was 20 vessels/field at the hot spot (range 1-73). The median number of tumour-infiltrating lymphocytes was 500 (range 100-5,000). The percentage absolute tumour uptake of the injected dose/cm{sup 3} tumour volume derived from tomographic images correlated linearly with FasL HSCORES(r=0.47, P=0.02). No correlation was found between the percentage absolute tumour uptake of the

  10. A modified {sup 99} Mo- {sup 99} Tc generator on Zirconium molybdo- phosphate-{sup 99} Mo gel. Vol. 3

    Energy Technology Data Exchange (ETDEWEB)

    El-Kolaly, M T; Talaat, H [Labelled Compounds Department, Cairo (Egypt); Botros, N [Radioistspe and Generator Department, Radioisotope Production and Sealed Source Division, Hot Laboratories Center, Atomic Energy Authority, Cairo (Egypt)

    1996-03-01

    A modified {sup 99} Mo - {sup 99} Tc gel generator is described. The new generator is based on the use of zirconium molybdophosphate - {sup 99} Mo gel in which {sup 99} Mo chemically combined in the gel structure, where {sup 99m}Tc can be easily eluted with distilled water or saline. The gel was prepared via chemical reaction between zirconyl chloride and molybdophosphate - {sup 99} Mo solution. The PH of the reaction mixture was adjusted with NaOH. Different gels have been prepared by varying the molar ratio of Mo:Zr:p. The PH and time of digeston on complete gel formation was also investigated in order to optimize the condition of gel preparation. Molybdophosphate {sup 32} P solution was used to determine the phosphorous content in the gel and in the {sup 99m}Tc eluate. The temperature and time of drying of the gel and their effect on {sup 99m}Tc elution efficiency were also studied. From the data obtained, the optimum conditions for routine production of {sup 99} Mo - {sup 99m}Tc generator are presented and discussed. 2 figs., 6 tabs.

  11. Determination of technetium-99 in environmental samples: A review

    International Nuclear Information System (INIS)

    Shi Keliang; Hou Xiaolin; Roos, Per; Wu Wangsuo

    2012-01-01

    Highlights: ► The source term, physicochemical properties, environmental distribution and behaviour of 99 Tc are presented. ► Various sample pre-treatment and pre-concentration techniques of technetium are discussed. ► Chemical separation and purification techniques for 99 Tc in environmental samples are reviewed. ► Measurement techniques for 99 Tc in environmental level and automated analytical methods are reviewed. ► The reported analytical methods of 99 Tc are critically compared to provide overall information. - Abstract: Due to the lack of a stable technetium isotope, and the high mobility and long half-life, 99 Tc is considered to be one of the most important radionuclides in safety assessment of environmental radioactivity as well as nuclear waste management. 99 Tc is also an important tracer for oceanographic research due to the high technetium solubility in seawater as TcO 4 − . A number of analytical methods, using chemical separation combined with radiometric and mass spectrometric measurement techniques, have been developed over the past decades for determination of 99 Tc in different environmental samples. This article summarizes and compares recently reported chemical separation procedures and measurement methods for determination of 99 Tc. Due to the extremely low concentration of 99 Tc in environmental samples, the sample preparation, pre-concentration, chemical separation and purification for removal of the interferences for detection of 99 Tc are the most important issues governing the accurate determination of 99 Tc. These aspects are discussed in detail in this article. Meanwhile, the different measurement techniques for 99 Tc are also compared with respect to advantages and drawbacks. Novel automated analytical methods for rapid determination of 99 Tc using solid extraction or ion exchange chromatography for separation of 99 Tc, employing flow injection or sequential injection approaches are also discussed.

  12. Concentration of sup(99m)Tc from the eluate of 99Mo-sup(99m)Tc generators

    International Nuclear Information System (INIS)

    Saucedo, T.; Mora, M.; Fraga de Suarez, A.H.; Mitta, A.E.A.

    1976-04-01

    A method is described to concentrate sup(99m)Tc solutions, originated in 99 Mo-sup(99m)Tc generators, independent of its age. The techniques of preparation of the different radiopharmaceuticals used in nuclear medicine are also described. (author) [es

  13. Problems in clinical practice of domestic supply of 99Mo/99mTc. Considerations on the domestic production of 99Mo/99mTc

    International Nuclear Information System (INIS)

    Yamabayashi, Hisamichi

    2012-01-01

    At present, a bulky import product, 99 Mo supplied in Japan is produced by a nuclear fission method which enables to produce a generator system with no need of commercially preparing 99m Tc-labeled radiopharmaceuticals due to its high specific activity. However its usage of enriched uranium target leads to avoiding the fission method from the option of domestic production. In order to secure the domestic supply of 99 Mo/ 99m Tc, the neutron activation method, aiming to meet about 20% of domestic demand, is under development along with the re-start program of JMTR. Development of various production methods using accelerators are also in progress. In those non-fission methods with reactors or accelerators, rapid and effective procedures for concentration and refinement of 99m Tc solution eluted from 99 Mo of low specific activity are the subjects to be considered for attaining the stable labeling performances. (author)

  14. Towards kit formulation of 99mTc labelled somatostatin receptor binding peptides of high specific activity for tumour localization

    International Nuclear Information System (INIS)

    Behe, M.; Powell, P.; Maecke, H.R.

    2001-01-01

    The project aimed to develop 99m Tc octreotide analogue for use in nuclear oncology. Several attempts to label SRIF analogues with 99m Tc have used a direct labelling approach but, for this project, HYNIC was chosen as a technetium ligand. A comparison of two different SRIF analogues designed for high specific activity labelling with 99m Tc was done. HYNIC-Octreotide and HYNIC-TOC were prepared and a kit formulation that can be labelled conveniently is currently being studied in a clinical setting. (author)

  15. How good is technetium-99m mercaptoacetyltriglycine indirect cystography?

    International Nuclear Information System (INIS)

    Sadeleer, C. de; Boe, V. de; Keuppens, F.; Desprechins, B.; Verboven, M.; Piepsz, A.

    1994-01-01

    The aim of the present study was to estimate the sensitivity of indirect radionuclide cystography (IRC) performed with technetium-99m mercaptoacetyltriglycine (MAG3), in comparison with the micturition cystourethrography (MCUG) and direct radionuclide cystography (DRC), for the diagnosis of vesicoureteric reflux. Two groups of patients were selected: group I comprised 40 children who underwent IRC during the acute phase of urinary tract infection and an MCUG 6 weeks later; group II comprised 42 (other) children with known reflux, who underwent IRC and DRC during follow-up. Taking as the reference the total number of refluxing kidneys detected by means of any cystographic technique, 99m Tc-MAG3 ICR missed two-thirds of the refluxing kidneys. Most of the small refluxes were missed, but so too were 50% of the major refluxes. Taking as the reference 99m Tc dimercaptosuccinic acid (DMSA) scintigraphy, MCUG detected 91% of the patients with DMSA abnormalities on at least one kidney, DRC detected 95%, and IRC detected 46% and 43% respectively, in groups I and II. The use of 99m Tc-MAG3 IRC as the sole technique for the detection of vesicoureteric reflux gives rise to an unacceptable number of false-negative results. (orig.)

  16. Laboratory research on back end issues of the Mo-99 production

    International Nuclear Information System (INIS)

    Falcon, M.; Russo, A.; Schickendantz, F.; Vaccaro, J.

    2002-01-01

    The Argentinean National Atomic Energy Commission (CNEA) is now beginning to produce fission 99Mo (parent of the radionuclide 99mTc, widely used in medicine) by irradiation of targets containing 20% enriched uranium. The reduction from the previously employed enrichment of 90% implies an increase in the mass of uranium necessary to produce the same 99Mo activity. This, and the fact that the irradiated uranium has a very low burn-up, led to the decision of studying the feasibility of a method for the recovery (and later reuse) of the irradiated uranium, in order to reduce purchase and post-irradiation storage costs. This task is part of a project for to improving several aspects of the 99Mo production process (including the recovery and purification of other valuable fission products, such as 137Cs, 90Sr and 133Xe). (author)

  17. Initial direct comparison of 99mTc-TOC and 99mTc-TATE in identifying sites of disease in patients with proven GEP NETs.

    Science.gov (United States)

    Cwikla, Jaroslaw B; Mikolajczak, Renata; Pawlak, Dariusz; Buscombe, John R; Nasierowska-Guttmejer, Anna; Bator, Andrzej; Maecke, Helmut R; Walecki, Jerzy

    2008-07-01

    The imaging of neuroendocrine tumors has become one of the most significant areas in nuclear oncology. In an attempt to provide high-quality imaging and possible sensitivity at a reduced cost, time, and radiation dose, several (99m)Tc agents have been proposed. The aim of this initial study was to compare the tumor uptake and biodistribution of 2 new 6-hydrazinopyridine-3-carboxylic acid (HYNIC)-derivatized Tyr(3)-octreotide analogs, (99m)Tc-[HYNIC,Tyr(3)]octreotide ((99m)Tc-TOC) and (99m)Tc-[HYNIC,Tyr(3),Thr(8)]octreotide ((99m)Tc-TATE), in patients with somatostatin receptor-expressing tumors. Each of 12 patients with proven gastrointestinal pancreatic neuroendocrine tumors received a mean activity of 520 MBq of (99m)Tc-TOC and (99m)Tc-TATE. Scintigraphy with both tracers was performed 3-4 h after their injection using standard whole-body and SPECT imaging. The images were reviewed subjectively by 2 readers, who reported tumor uptake lesion by lesion. Both radiotracers demonstrated concordance between the results in 7 patients (58%). In total, 110 sites of disease were identified with (99m)Tc-TOC, compared with 115 with (99m)Tc-TATE. There was 1 case in which (99m)Tc-TOC identified sites of disease not seen on (99m)Tc-TATE imaging but 4 cases in which some sites of disease were seen with (99m)Tc-TATE and not (99m)Tc-TOC. In this initial study, both tracers seem to show similar sites of tumor, with (99m)Tc-TATE having a slight edge in the total number of lesions seen, especially in lymph node metastases.

  18. Final report on LDRD project: Simulation/optimization tools for system variability analysis

    Energy Technology Data Exchange (ETDEWEB)

    R. L. Bierbaum; R. F. Billau; J. E. Campbell; K. D. Marx; R. J. Sikorski; B. M. Thompson; S. D. Wix

    1999-10-01

    >This work was conducted during FY98 (Proposal Number 98-0036) and FY99 (Proposal Number 99-0818) under the auspices of the Sandia National Laboratories Laboratory-Directed Research and Development (LDRD) program. Electrical simulation typically treats a single data point in the very large input space of component properties. For electrical simulation to reach its full potential as a design tool, it must be able to address the unavoidable variability and uncertainty in component properties. Component viability is strongly related to the design margin (and reliability) of the end product. During the course of this project, both tools and methodologies were developed to enable analysis of variability in the context of electrical simulation tools. Two avenues to link relevant tools were also developed, and the resultant toolset was applied to a major component.

  19. The clinical value of 99Tcm-N-NOET exercise and delayed myocardial perfusion imaging in patients with hypertension

    International Nuclear Information System (INIS)

    Wei Hua; Li Sijin; Liu Jianzhong; Wu Zhifang; Liu Haiyan; Hu Guang; Wang Jin; Li Qing

    2010-01-01

    Objective: To investigate clinical significance of the 99 Tc m -bis (N-ethoxy-N-ethyl-dithiocar-bamato) nitridotechnetium ( 99 Tc m -N-NOET) exercise and delayed myocardial perfusion imaging (MPI) in hypertensive patients. Methods: Sixty patients with hypertension and 19 normal subjects were carried out 99 Tc m -N-NOET exercise and delayed MPI, and analyzed the results of MPI, exercise electrocardiography (ECG), cardiac function parameters end-diastolic volume (EDV), end-systolic volume (ESV), left ventricular ejection fraction (LVEF), triangle open LVEF (LVEF exercis-LVEF delay) and coronary angiography (CAG). Results: 1) Sixty patients with hypertension, 22 cases (36.7%) of exercise ECG were abnormal, 16 cases (26.7%) were the chest tightness in exercise, 13 cases (21.7%) were blood pressure excessive reaction in exercise; control group, 2 cases (10.5%) of exercise ECG were abnormal, 1 case (5.3%, 1/19) was chest tightness in exercise, no person was blood pressure response in excessive. 2) The positive rate of myocardial perfusion in hypertensive group was significantly higher than the control group (31.75%vs. 5.30%, P 0.05), triangle open LVEF 2 =4.501, P 2 =0.25, P>0.05). The sensitivity, specificity and accuracy of 99 Tc m -N-NOET MPI were 72.7%, 87.5% and 78.9%. Conclusions: 1) 99 Tc m -N-NOET exercise and delayde MPI can diagnose whether hypertension patients with myocardial ischemia or not. 2) triangle open LVEF of hypertensive patients reduced, triangle open LVEF is lower in hypertensive patients of MPI-positive. (authors)

  20. Mo-99 supply issues: Status report and lessons learned

    International Nuclear Information System (INIS)

    Ponsard, B.

    2010-01-01

    The worldwide supply of 99 Mo relies on a limited number of research reactors and processing facilities. Its production is essential for the nuclear medicine as 99m Tc, obtained from 99 Mo/ 99m Tc generators, is used in about 80% of the diagnostic nuclear imaging procedures. These applications represent yearly approximately 30 million examinations worldwide. The short half-life's of 99 Mo (66 hours) and its daughter 99m Tc (6 hours) require a regular supply of 99 Mo/ 99m Tc generators to hospitals or central radiopharmacies. Currently, there are only five nuclear reactors involved in the production of 99 Mo on industrial scale: NRU (Canada), HFR (Netherlands), BR2 (Belgium), OSIRIS (France) and SAFARI (South Africa). They irradiate highly enriched uranium targets for the production of about 95% of the available 99 Mo by four processing facilities: AECL/MDS NORDION (Canada), COVIDIEN (Netherlands), IRE (Belgium) and NTP (South Africa). However, these ageing reactors are subject to unscheduled shutdowns and longer maintenance periods making the 99 Mo supply chain vulnerable and unreliable. Several severe disruptions have been experienced since the fall 2005 due to the occurrence of problems at different stages of the supply chain: reactor outages, release of activity from processing facilities, recall of 99 Mo/ 99m Tc generators by the manufacturers, ... It is not expected that the situation will improve significantly in the near future. Therefore, several workshops have been organized in 2009 by the OECD Nuclear Energy Agency (NEA), the International Atomic Energy Agency (IAEA) and the Association of Imaging Producers and Equipment Suppliers (AIPES) to define measures that should be taken to secure the 99 Mo supply in the short, medium and long term. This paper summarizes the current status of the 99 Mo supply, discusses the ongoing plans for additional 99 Mo production capacity and outlines the issues for a reliable global supply chain. (author)

  1. 10 CFR 76.119 - Security facility approval and safeguarding of National Security Information and Restricted Data.

    Science.gov (United States)

    2010-01-01

    ... 10 Energy 2 2010-01-01 2010-01-01 false Security facility approval and safeguarding of National Security Information and Restricted Data. 76.119 Section 76.119 Energy NUCLEAR REGULATORY COMMISSION... approval and safeguarding of National Security Information and Restricted Data. The requirements for...

  2. 77 FR 73916 - Regulated Navigation Area; S99 Alford Street Bridge Rehabilitation Project, Mystic River, MA

    Science.gov (United States)

    2012-12-12

    ... against hazardous conditions created by repair work on the S99 Alford Street Bridge across the Mystic... navigation area that was promulgated to protect the public against hazardous conditions created by repair... restaurants), and vessels who intend to transit in the Mystic River beneath the S99 Alford Street Bridge...

  3. Labelled Preformed liposomes with 99MTC-DTPA, 99 MTC-ECD, 99MTC-MDP and 99MTC-MIBI : Labelling procedures and stability studies

    International Nuclear Information System (INIS)

    Savio, E.O.; Teran, M.A.; Vales, M.E.; Frier, M.

    2004-01-01

    Liposomes labelled with gamma e miters like 99mTc, can be used for scintigraphic imaging to non-invasively track and quantify the distribution of liposomes in the body. In vitro studies were done to choose a suitable radiopharmaceutical (RF) to be attached to performed liposomes. 99mTc-Complexes (DTPA, ECD, MDP, MIBI) were used to label collagen liposomes. Commercial kits were labelled with 99mTc04-(TechnoNuclear). Quality controls of the RF were performed. Collagen liposomes suspended in saline 0.9% were incubated at 4.25.37 and 60 for 30 min. Efficiency of the labelling procedure was determined by gel filtration using Sephadex G25 (Pharmacia) and NaC10.9%. Samples of 100mL (74MBq), were seeded and fractions of 0.5mL were colleted and measured in an ionisation chamber (Capintec CRC). Stability of the labelled liposomes was assessed incubating 0.5mL, of the suspension with 1mL of human serum during 30 min at 37 . Dialysis was performed using dialysis bags of 64 K pore size and NaCI 0.9% at room temperature. Samples of the saline bath were collected at 30.60 and 90 min. and measured in a solid scintillation counter Ortec.Liposomes labelled with 99mTc-DTPA and 99mTcMIBI showed a labelling efficiency of 80%; liposomes incubated with 99mTc-MDP were labelled in a 50% and 99mTc-ECD did not bind to liposomes in the conditions of study. Incubation of labelled liposomes with human serum showed 50% of strong binding to the plasmatic proteins for 99mTc-DTPA but low values (5%) for the other specimens. Labelled liposomes were achieved, with different RF, showing a suitable in vitro stability to perform in vivo studies

  4. Comparison of 99m-Tc-MDP and 99m-Tc-MIBI whole body scans for diagnosis of widespread skeletal metastases

    International Nuclear Information System (INIS)

    Ansari, M.; Hoshiar, A.; Mortazavi, S.H.

    2002-01-01

    Skeletal metastasis is one of the most important disabling complications of the malignant diseases. As in general, the survival of patients with osteometastatic lesions is relatively long, an early diagnosis can lead to improve the patient's life, both quantitatively and qualitatively and prevent exacerbation of the disease and disabling complications. In this study 22 patients with established diagnosis of malignant disease and clinical manifestations of skeletal metastasis were evaluated both with 99 m-Tc-MIBI and 99 m-Tc-MDP whole body scans, in two separate phases. Patient's diagnosis were as following: small round cell tumor, breast carcinoma. Nasopharynx carcinoma and multiple myeloma. In the first phase of the study a whole body bone scan was performed by IV injection of 740MBq 99 m-Tc-MDP. After a period of 1 week a whole body scan carried out by 99 m-Tc-MDP for all the patients. No treatment such as radiation therapy ar chemotherapy was done in this 1 week interval. The number and intensity of the scan findings were compared visually, according to the three- phase staging, subsequently. whole body survey with 99 m-Tc-MDP in 14 out 22 patient were positive demonstrating only 44.4% of body lesions established on whole body bone scan with 99 m-Tc-MDP. The mean value of intensity of radiotracer uptake was around 1.5+ (mild to moderate ). on the other hand in 7 patients with positive 99 m-Tc-MDP scan some hidden soft tissue lesions ( mostly lymph nodes) were detected with intensity of 2+. So this study shows that whole body bone scan is preferable for detection of widespread metastasis comparing with 99 m-Tc-MDP whole body scan. the significance of 99 m-Tc-MDP scan is mainly limited to some equivocal of soft tissue lesions

  5. Importance of a 99Mo/99mTc generator and a perspective of nuclear medicine in the face of the difficult situation of supply shortage of 99mTc from the view-point of a nuclear medicine specialist

    International Nuclear Information System (INIS)

    Kosuda, Shigeru

    2010-01-01

    In this review a list of commercially available 99m Tc-labeled radiopharmaceuticals was presented, and the significance to use them clinically was described in the face of this difficult situation due to the 99m Tc shortage. The supply history and the chronological change in the sales of 99 Mo/ 99m Tc generators in Japan were also described. I emphasize the importance of a nationwide spread of dedicated single photon emission computed tomography (SPECT)/CT equipments, which provide not only a simultaneous acquisition of dual tracers, but also information on both function and morphology. The present issues to address this difficult situation were discussed, referring to the summary of the Organization for Economic Co-operation and Development (OECD)/the Nuclear Energy Agency (NEA) workshop held in Paris and the press conference at the 56 th Society of Nuclear Medicine (SNM) annual meeting held in Toronto. The results of a questionnaire survey conducted in Saitama prefecture suggested the procedures, such as a domestic self-supply of 99 Mo, to resolve the issues related to the shortage. In addition, the ongoing Japan Materials Testing Reactor (JMTR) project regarding self-supply of 99 Mo was described. Based on a reliable supply of 99m Tc, the following suggestions to develop nuclear medicine were presented from the viewpoint of a nuclear medicine specialist; development of a brand-new SPECT/CT equipment using semi-conductor, clinical application of new tracers, and reassessment of the existing SPECT studies. (author)

  6. Comparative study of 99Mo/99mTc generators at base of synthesized gels starting from activation and fission 99Mo

    International Nuclear Information System (INIS)

    Lopez M, I.Z.; Monroy G, F.; Rivero G, T.; Rojas N, P.

    2007-01-01

    The 99m Tc is used for diagnostic and therapy. It is produced starting from 99 Mo, absorbed in chromatographic columns, loaded with alumina that absorb only 0.2% of 99 Mo with high specific activities of 99 Mo, obtained from the 235 U fission. Given these conditions and limitations, new preparation procedures of 99 Mo/ 99m Tc generators, its have been developed, using zirconium molybdates gels that incorporates until 30% of 99 Mo, conserve similar characteristics of quality and purity that the traditional generator. The radiochemical characteristics of the 99m Tc elution, depend strongly on the gel preparation conditions. In particular, the present work has by object to determine the influence of the 99 Mo used type, fission or activation product, during the gels synthesis, as well as the used air flow for the agitation in the gels preparation and its influence in the 99 Mo/ 99m Tc generators quality. When diminishing the flow of agitation air the efficiency it increases and in the radionuclide purity of the eluates and when using 99 Mo from fission for the gels production it increases in an important way the elutriation efficiency, the radiochemical and radionuclide purity of the 99m Tc eluates. (Author)

  7. Karistusseadustiku § 119¹ ehk tõenduslike probleemide ületamine materiaalõiguse abil / Anneli Soo, Birgit Sisask

    Index Scriptorium Estoniae

    Soo, Anneli, 1984-

    2015-01-01

    1. jaanuaril 2015 jõustus karistusseadustikus rida muudatusi, sh lisandus § 119¹, mis käsitleb kakluses osalemist. Karistusõiguslikest ja põhiseaduslikest põhimõtetest, millega § 119¹ läheb vastuollu

  8. 75 FR 8918 - Approval for Subzone Expansion and Expanded Manufacturing Authority; Foreign-Trade Subzone 119B...

    Science.gov (United States)

    2010-02-26

    ... and Expanded Manufacturing Authority; Foreign-Trade Subzone 119B, Uponor, Inc. (Polyethylene Tubing); Apple Valley, MN Pursuant to its authority under the Foreign-Trade Zones Act of June 18, 1934, as... Zone 119 (Minneapolis, Minnesota), has submitted a request on behalf of Uponor, Inc. (Uponor), operator...

  9. The Supply of Medical Radioisotopes. Results from the Second Self-assessment of the Global 99Mo/99mTc Supply Chain

    International Nuclear Information System (INIS)

    Peykov, Pavel; Cameron, Ron

    2014-07-01

    self-assessment review of the 99 Mo/ 99m Tc supply chain. Chapter 4 provides an analysis of the results and makes observations on current and projected future capacity and demand for 99 Mo/ 99m Tc. Chapter 5 details each country's progress towards implementing the HLG-MR policy approach, including the governments' role in the market. Chapter 6 summarises the progress made by the supply chain towards implementing full-cost recovery and outage reserve capacity since the first self-assessment. Chapter 7 presents the conclusions of the second self-assessment review of the 99 Mo/ 99m Tc supply chain. (authors)

  10. Gentc99m, computational system for the technetium-99m generator

    International Nuclear Information System (INIS)

    Suparman, I.

    1997-01-01

    The technetium-99m generator is one of the main products of the PPR, as the continuity of the technetium-99m generator production is important for supporting the development of nuclear medicine. GENTC99M has been made for computational for the technetium-99m generator and includes data processing, documentation and information GENTC99M is also very useful in quality control application especially for the determinations of yield and radionuclidic impurities which consume much time. microsoft visual basic for MS-DOS and visual basic for windows have been used for making GENTC99M. Microsoft visual basic has several features that make it an ideal development language for both MS-DOS and Microsoft Windows. These features not only increase productivity, they also provide all the tools and hooks needed to develop some very sophisticated applications. for a production centre like PPR, GENTC99M is very useful to support the data processing, documentation and information system of the technetium-99m generator and it can also be modified for other products

  11. 13 CFR 119.11 - What information will be requested in an application under the PRIME program?

    Science.gov (United States)

    2010-01-01

    .... (2) A research proposal indicating the thesis, method(s), scope, duration, and implementation plans... 13 Business Credit and Assistance 1 2010-01-01 2010-01-01 false What information will be requested in an application under the PRIME program? 119.11 Section 119.11 Business Credit and Assistance SMALL...

  12. Project Solo; Newsletter Number Twenty.

    Science.gov (United States)

    Pittsburgh Univ., PA. Project Solo.

    Three Project Solo modules are presented. They are designed to teach the concepts of elementary matrix operation, matrix multiplication, and finite-state automata. Together with the module on communication matrices from Newsletter #17 they form a well motivated but structured path to expertise in this area. (JY)

  13. Cellular responses to modified Plasmodium falciparum MSP119 antigens in individuals previously exposed to natural malaria infection

    Directory of Open Access Journals (Sweden)

    Awobode Henrietta O

    2009-11-01

    Full Text Available Abstract Background MSP1 processing-inhibitory antibodies bind to epitopes on the 19 kDa C-terminal region of the Plasmodium falciparum merozoite surface protein 1 (MSP119, inhibiting erythrocyte invasion. Blocking antibodies also bind to this antigen but prevent inhibitory antibodies binding, allowing invasion to proceed. Recombinant MSP119 had been modified previously to allow inhibitory but not blocking antibodies to continue to bind. Immunization with these modified proteins, therefore, has the potential to induce more effective protective antibodies. However, it was unclear whether the modification of MSP119 would affect critical T-cell responses to epitopes in this antigen. Methods The cellular responses to wild-type MSP119 and a panel of modified MSP119 antigens were measured using an in-vitro assay for two groups of individuals: the first were malaria-naïve and the second had been naturally exposed to Plasmodium falciparum infection. The cellular responses to the modified proteins were examined using cells from malaria-exposed infants and adults. Results Interestingly, stimulation indices (SI for responses induced by some of the modified proteins were at least two-fold higher than those elicited by the wild-type MSP119. A protein with four amino acid substitutions (Glu27→Tyr, Leu31→Arg, Tyr34→Ser and Glu43→Leu had the highest stimulation index (SI up to 360 and induced large responses in 64% of the samples that had significant cellular responses to the modified proteins. Conclusion This study suggests that specific MSP119 variants that have been engineered to improve their antigenicity for inhibitory antibodies, retain T-cell epitopes and the ability to induce cellular responses. These proteins are candidates for the development of MSP1-based malaria vaccines.

  14. The Midden Mound Project. Report of Investigations Number 6

    Science.gov (United States)

    1987-01-01

    weighed on an O’haus triple-beam balance. The wood was identified to the genus level by comparison to speciuens in the comparative collection at Auburn...daminated (99.2%) by hickory nutshell fragments, but also contained a grape seed, a persinnon fragment ( Diospyros virginiana), and hardwood fragments. 212 0

  15. 25 CFR 700.119 - Establishment of fair market value.

    Science.gov (United States)

    2010-04-01

    ... 25 Indians 2 2010-04-01 2010-04-01 false Establishment of fair market value. 700.119 Section 700... value. (a) General. The Commission shall establish the amount of fair market value to be offered to the... recommendations as to the fair market value of the habitations and/or improvements; or (2) The fair market value...

  16. Mismatched uptake of Tc-99m-ECD and Tc-99m-HMPAO in subacute cerebral infarction: Tc-99m-ECD for viability and Tc-99m-HMPAO for flow restoration

    Energy Technology Data Exchange (ETDEWEB)

    Lee, D. S.; Hyun, I. Y.; Kim, S. K. [College of Medicine, Seoul National Univ., Seoul (Korea, Republic of)] [and others

    1997-07-01

    Tc-99m-HMPAO reflects tissue perfusion but Tc-99m-ECD uptake is affected by tissue viability in addition to tissue perfusion which the varied state of cellular retention of Tc-99m-ECD reflects. Luxuriously perfused area on Tc-99m-HMPAO SPECT implies that this cortex was already reperfused either spontaneously or after thrombolysis and that accompanied paralysis of vascular reactivity in those zones warms progressive deterioration. We tried to find out if we can use sequential Tc-99m-ECD/Tc-99m-HMPAO SPECT to reveal cortical perfusion and severity and range of risky areas of cerbral cortex despite reperfusion in sub-acute infarction. In 13 patients (M ; F =7 : 6, mean age 57 (range: 26-84)) with cortical (n=12) and basal ganglia infarction (1), we performed sequential Tc-99m-ECD/Tc-99m-HMPAO SPECT at the same position. At first, 555 MBq of Tc-99m-ECD was injected and imaged and then 1110 MBq of Tc-99m-HMPAO was injected again and imaged with the patients in situ, and the first image (Tc-99m-ECD) and the subtracted image (2nd- 1st : Tc-99m-HMPAO) were compared slice by slice. Study was done from 3 days to 31 days (16{+-}9) after ictus. Tc-99m-ECD uptake was always less than or equal to Tc-99m-HMPAO uptake at the lesion in all cases. Luxury perfusion was prominent in four patients. Mismatched uptake was found in 10 patients. Severity of mismatch showed diverse spectrum and was ranged from total middle cerebral artery territory (1 case) to peripheral thin zones around infarction (2 cases). The other 7 showed intermediate amount of tissues with mismatch , i.e., Tc-99m-ECD defects where Tc-99m-HMPAO uptake is in part increased, normal or decreased. Upon discharge, patients having more uptake with Tc-99m-ECD predicted improvement. Patients having mismatched uptake went dichotomous way. In conclusion, Tc-99m-ECD/Tc-99m-HMPAO sequential SPECT is feasible and reveal both tissue perfusion (Tc-99m-HMPAO ) and discrepant Tc-99m-ECD uptake probably reflecting viability in acute

  17. Preparation of 99Mo/99mTc generators based on 99Mo zirconium molybdates in the Gel Synthesis Device for Generators

    International Nuclear Information System (INIS)

    Lopez M, I. Z.; Monroy G, F.; Rivero G, T.; Rojas N, P.

    2008-01-01

    The 99m Tc is used for diagnosis and therapy. It is produced commercially from 99 Mo obtained from the fission of 235 U, which is retained in chromatographic columns filled with alumina whose maximum capacity is 0.2%. Given these constraints new methods of preparation 99 Mo/ 99m Tc generators have been developed using zirconium molybdates gels containing up to 30% of Mo, which is part of the generator matrix, and retaining quality and purity similar characteristics to those commercial generators. The present study aims to determine the flow of agitation, temperature and drying time optimal to prepare 99 Mo/ 99m Tc generators based on 99 Mo zirconium molybdates in the Gel Synthesis Device 99 Mo/ 99m Tc Generators designed and built by groups of the Radioactive Materials Research Laboratory and Automation and Instrumentation Department of the National Institute of Nuclear Research. (Author)

  18. Study of different absorbent materials for the preparation of generator systems of 99Mo - 99mTc and 188W-188Re

    International Nuclear Information System (INIS)

    Lopes, Paula Regina Corain; Osso Junior, Joao Alberto

    2009-01-01

    Amongst some currently radioisotopes, 99m Tc and 188 Re present adequate decay properties for use in Nuclear Medicine. In the current times the most diagnosis examinations are performed with 99m Tc and 188 Re is one radioisotope of potential use in therapy techniques. The objective of this work consists of determining the capacity of some adsorbent materials for retention of molybdenum and tungsten, aiming the optimization of generator systems of 99 Mo- 99m Tc and 188 W- 188 Re with suitable characteristics for application in Nuclear Medicine. Known amounts, in mass, of molybdenum and tungsten were percolated through different chromatographic columns containing different commercial adsorbent materials such as: PZC (poly-zirconium compound), acid alumina and calcinated alumina used in the routine preparation of 99 Mo- 99m Tc generators at IPEN. The tungsten ( 188 W), as well the PZC used in this project, supplied by Russia and Japan, respectively, through the International Atomic Energy Agency (IAEA) and used without any previous preparation. Also trace amounts of 99 Mo and 188 W were added to the initial solutions and the generators were assembled. The 99 Mo- 99m Tc generators were then eluted with known volumes of 0.9% NaCl solution every 24 hours whereas the 188 W- 188 Re generators were eluted every 48 hours. The eluted samples were analyzed by Gamma Spectroscopy and later submitted to quality control evaluation. The results showed that the PZC presents superior retention capacity for Mo of 97.50mg Mo/gPZC, higher than in acid and calcinated alumina, however the elution efficiency at lower pHs is not so high. With regards to the experiments carried out with 188 W and alumina, it was verified that the elution efficiency of 188 Re was not reproducible and the retention capacity of W was 90.23mgW/gAl 2 O 3 at pH 7. (author)

  19. Altered [99mTc]Tc-MDP biodistribution from neutron activation sourced 99Mo.

    Science.gov (United States)

    Demeter, Sandor; Szweda, Roman; Patterson, Judy; Grigoryan, Marine

    2018-01-01

    Given potential worldwide shortages of fission sourced 99 Mo/ 99m Tc medical isotopes there is increasing interest in alternate production strategies. A neutron activated 99 Mo source was utilized in a single center phase III open label study comparing 99m Tc, as 99m Tc Methylene Diphosphonate ([ 99m Tc]Tc-MDP), obtained from solvent generator separation of neutron activation produced 99 Mo, versus nuclear reactor produced 99 Mo (e.g., fission sourced) in oncology patients for which an [ 99m Tc]Tc-MDP bone scan would normally have been indicated. Despite the investigational [ 99m Tc]Tc-MDP passing all standard, and above standard of care, quality assurance tests, which would normally be sufficient to allow human administration, there was altered biodistribution which could lead to erroneous clinical interpretation. The cause of the altered biodistribution remains unknown and requires further research.

  20. 9 CFR 381.119 - Declaration of artificial flavoring or coloring.

    Science.gov (United States)

    2010-01-01

    ... 9 Animals and Animal Products 2 2010-01-01 2010-01-01 false Declaration of artificial flavoring or..., DEPARTMENT OF AGRICULTURE AGENCY ORGANIZATION AND TERMINOLOGY; MANDATORY MEAT AND POULTRY PRODUCTS INSPECTION... Containers § 381.119 Declaration of artificial flavoring or coloring. (a) When an artificial smoke flavoring...

  1. Preparation and biological profile of 99mTc-lidocaine as a cardioselective imaging agent using 99mTc eluted from 99Mo/99mTc generator based on Al-Mo gel

    International Nuclear Information System (INIS)

    Sakr, T.M.; October University of Modern Sciences and Arts; Ibrahim, A.B.; Rashed, H.M.; Fasih, T.W.

    2017-01-01

    The current study is aimed to prepare 99m Tc-lidocaine as a new myocardial perfusion-imaging agent. The used 99m Tc was obtained from Al- 99 Mo-molybdate(VI) gel matrix. 99m Tc-lidocaine showed higher (15.4 ± 0.11% ID/g) and faster (15 min post injection) cardiac uptake than the recently studied 99m Tc-valsartan and 99m Tc-procainamide. Consequently, 99m Tc-lidocaine will be a valuable myocardial SPECT agent for diagnosis of emergency patients. Besides, the receptor affinity study confirmed the selectivity of 99m Tc-lidocaine for sodium channels in the heart. (author)

  2. Broadly reactive antibodies specific for Plasmodium falciparum MSP-119 are associated with the protection of naturally exposed children against infection

    Directory of Open Access Journals (Sweden)

    Dent Arlene E

    2012-08-01

    Full Text Available Abstract Background The 19 kDa C-terminal region of Plasmodium falciparum Merozoite Surface Protein-1 is a known target of naturally acquired humoral immunity and a malaria vaccine candidate. MSP-119 has four predominant haplotypes resulting in amino acid changes labelled EKNG, QKNG, QTSR and ETSR. IgG antibodies directed against all four variants have been detected, but it is not known if these variant specific antibodies are associated with haplotype-specific protection from infection. Methods Blood samples from 201 healthy Kenyan adults and children who participated in a 12-week treatment time-to-infection study were evaluated. Venous blood drawn at baseline (week 0 was examined for functional and serologic antibodies to MSP-119 and MSP-142 variants. MSP-119 haplotypes were detected by a multiplex PCR assay at baseline and weekly throughout the study. Generalized linear models controlling for age, baseline MSP-119 haplotype and parasite density were used to determine the relationship between infecting P. falciparum MSP-119 haplotype and variant-specific antibodies. Results A total of 964 infections resulting in 1,533 MSP-119 haplotypes detected were examined. The most common haplotypes were EKNG and QKNG, followed by ETSR and QTSR. Children had higher parasite densities, greater complexity of infection (>1 haplotype, and more frequent changes in haplotypes over time compared to adults. Infecting MSP-119 haplotype at baseline (week 0 had no influence on haplotypes detected over the subsequent 11 weeks among children or adults. Children but not adults with MSP-119 and some MSP-142 variant antibodies detected by serology at baseline had delayed time-to-infection. There was no significant association of variant-specific serology or functional antibodies at baseline with infecting haplotype at baseline or during 11 weeks of follow up among children or adults. Conclusions Variant transcending IgG antibodies to MSP-119 are associated with protection

  3. Lessons Learned Following the Successful Decommissioning of a Reaction Vessel Containing Lime Sludge and Technetium-99

    International Nuclear Information System (INIS)

    Dawson, P. M.; Watson, D. D.; Hylko, J. M.

    2002-01-01

    This paper documents how WESKEM, LLC utilized available source term information, integrated safety management, and associated project controls to safely decommission a reaction vessel and repackage sludge containing various Resource Conservation and Recovery Act constituents and technetium-99 (Tc-99). The decommissioning activities were segmented into five separate stages, allowing the project team to control work related decisions based on their knowledge, experience, expertise, and field observations. The information and experience gained from each previous stage and rehearsals contributed to modifying subsequent entries, further emphasizing the importance of developing hold points and incorporating lessons learned. The hold points and lessons learned, such as performing detailed personal protective equipment (PPE) inspections during sizing and repackaging operations, and using foam-type piping insulation to prevent workers from cutting or puncturing their PPE on sharp edge s or small shards generated during sizing operations, minimized direct contact with the Tc-99. To prevent the spread of contamination, the decommissioning activities were performed inside a containment enclosure connected to negative air machines. After performing over 235 individual entries totaling over 285 project hours, only one first aid was recorded during this five-stage project

  4. Comparative study of 99Mo/99mTc generators at base of synthesized gels starting from 99Mo of activation and of fission

    International Nuclear Information System (INIS)

    Lopez M, I.Z.; Monroy G, F.; Rivero G, T.; Rojas N, P.

    2007-01-01

    At the present time the more used and diffused radionuclide in nuclear medicine it is the Technetium 99 metastable ( 99 mTc) it is used for diagnostic and therapy. It is produced starting from molybdenum 99 ( 99 Mo), which is absorbed in chromatographic columns, loaded with alumina that absorb only 0.2% of 99 Mo situation that forces to use high specific activities of 99 Mo that it is obtained starting from the fission of the 235 U. Given these conditions and limitations, new preparation procedures of 99 Mo/ 99m Tc generators, of low or medium specific activity, its have been developed, using gels of zirconium molybdates that incorporates until 30% in weight of 99 Mo in the gel, and also conserve similar characteristics of quality and purity that those obtained by the traditional generator; reducing by this way the cost of production of the 99m Tc, when using 99 Mo of low specific activity, in the preparation of 99 Mo/ 99m Tc generators. The radiochemical characteristics of the elution of 99m Tc, depends strongly on the gel preparation conditions. In particular, the present work has for object to determine the influence of the used type of 99 Mo, fission or activation product, during the gels synthesis, as well as the used air flow for the agitation in the gels preparation and its influence in the quality of the 99 Mo/ 99m Tc generators. When diminishing the agitation air flow the efficiency it increases and in the radionuclide purity of the eluates and when using 99 Mo of fission for the gels production it increases in an important way the elution efficiency, the radiochemical purity and radionuclide of the eluates of 99m Tc. (Author)

  5. Alligator Rivers Analogue project. Geochemistry of 239Pu, 129I, 99Tc and 36Cl

    International Nuclear Information System (INIS)

    Fabryka-Martin, J.T.; Curtis, D.B.

    1992-01-01

    One objective of this research programme has been to evaluate the applicability of uranium orebodies as natural analogues for testing radionuclide release-rate models used in performance assessment activities. The investigated nuclides included three of the most persistent radioactive constituents of high-level wastes from nuclear fission power reactors: plutonium-239, iodine-129, and technetium-99. The feasibility of uranium minerals as analogues for the behavior of these nuclear reaction products (NRP) in spent fuel relies upon a capability to characterise NRP concentrations in the source minerals. Measured abundances of natural 239 Pu, 99 Tc and 129 I in uranium ores are compared to calculated abundances in order to evaluate the degree to retention of these radionuclides by the ore. This modelling study also shows the extent to which various NRP are correlated, such that one provides a constraint on the production rates of others. Under most conditions, 36 Cl, another long-lived neutron-capture product found in uranium ores, is shown to be an ideal in-situ monitor of the 235 U fission rate, which is the dominant source term for 129 I and possibly a significant one for 99 Tc. Similarly, 239 Pu/U ratios can be used to establish limits on the 238 U neutron-induced fission rate; the ratios measured in this study suggest that 238 U induced fission comprises 129 I and 99 Tc. 79 refs., 21 tabs., 18 figs

  6. Technetium-99 in ''instant'' sup(99m)Tc-pertechnetate

    International Nuclear Information System (INIS)

    Mattsson, S.

    1978-01-01

    The 99 Tc-content in sup(99m)Tc-pertechnetate separated from 99 Mo by distillation or extraction has been studied with a plastic scintillation detector. The identification of the measured activity was achieved by beta-spectrometry, chemical separation and half-life studies. The frequency distribution of the sup(99)Tc/sup(99m)Tc-ratios in the different samples was observed to be log-normal. The most likely activity ratio was 0.4x10 -6 , the maximum value being 5x10 -6 . The specific activity of ''instant'' pertechnetate is approximately a factor of 60 lower than that normally recorded in pertechnetate derived from daily eluted column generators. The low specific activity of ''instant'' pertechnetate is primarily explained by the long time between separation and usage and secondly by the low yield of Tc in the distillation and extraction processes. In several of the ''instant'' pertechnetate solutions the carrier concentration exceeded the reductive capacity of the stannous ions in ''kits'' with small amounts of Sn(II) in usable form. (T.G.)

  7. Detection and localization of enlarged parathyroid glands in patients with hyperparathyroidism using 99mTc-methoxyisobutylisonitrile (MIBI). A study of subtraction scintigraphy with 99mTc-pertechnetate

    International Nuclear Information System (INIS)

    Katagiri, Makoto; Ohtawa, Takahiro; Otsuka, Nobuaki; Morita, Koichi; Sone, Teruki; Mimura, Hiroaki; Yanagimoto, Shinichi; Fukunaga, Masao; Harada, Tanekazu

    1995-01-01

    In this study we investigated the detectability of abnormal parathyroid gland(s) by 99m Tc-methoxy-isobutylisonitrile (MIBI) scintigraphy in patients with hyperparathyroidism. The subjects were 6 patients with primary hyperparathyroidism (PHP) with a single adenoma and 13 patients with renal hyperparathyroidism (RHP) on chronic maintenance hemodialysis. The imaging data of 99m Tc-pertechnetate were subtracted from those of 99m Tc-MIBI (MIBI-Tc), and number and location of the positive images on scintigrams were compared with those obtained by conventional scintigraphy using 201 Tl-Cl and 99m Tc-pertechnetate (Tl-Tc). All of the patients underwent surgery, and the number and location of the abnormal parathyroid glands were confirmed. The number of resected parathyroid glands were 6 in PHP and 52 in RHP. The detectability of MIBI-Tc was 83.3% in PHP and 51.9% in RHP, while that of Tl-Tc was 100% and 44.2%, respectively. Although no statistically significant difference in the detectability was found between MIBI-Tc and Tl-Tc, the number of false positives with MIBI-Tc was less than that with Tl-Tc. The detectability of MIBI-Tc depended on the size of the parathyroid gland. The maximal diameter and weight of the smallest parathyroid gland detected were 15 mm and 290 mg in PHP, and 9 mm and 50 mg in RHP. The existence of the thyroid gland did not reduce the detectability of MIBI-Tc. In conclusion, MIBI-Tc was clinically very useful for the detection of abnormal parathyroid glands in patients with hyperparathyroidism. (author)

  8. Potential Ways to Address Shortage Situations of 99Mo/99mTc.

    Science.gov (United States)

    Filzen, Leah M; Ellingson, Lacey R; Paulsen, Andrew M; Hung, Joseph C

    2017-03-01

    99m Tc, the most common radioisotope used in nuclear medicine, is produced in a nuclear reactor from the decay of 99 Mo. There are only a few aging nuclear reactors around the world that produce 99 Mo, and one of the major contributors, the National Research Universal (Canada), ceased production on October 31, 2016. The National Research Universal produced approximately 40% of the world's 99 Mo supply, so with its shut down, shortages of 99 Mo/ 99m Tc are expected. Methods: Nuclear pharmacies and nuclear medicine departments throughout the United States were contacted and asked to provide their strategies for coping with a shortage of 99 Mo/ 99m Tc. Each of these strategies was evaluated on the basis of its effectiveness for conserving 99m Tc while still meeting the needs of the patients. Results: From the responses, the following 6 categories of strategies, in order of importance, were compiled: contractual agreements with commercial nuclear pharmacies, alternative imaging protocols, changes in imaging schedules, software use, generator management, and reduction of ordered doses or elimination of backup doses. Conclusion: The supply chain of 99 Mo/ 99m Tc is quite fragile; therefore, being aware of the most appropriate coping strategies is crucial. It is essential to build a strong collaboration between the nuclear pharmacy and nuclear medicine department during a shortage situation. With both nuclear medicine departments and nuclear pharmacies implementing viable strategies, such as the ones proposed, the amount of 99m Tc available during a shortage situation can be maximized. © 2017 by the Society of Nuclear Medicine and Molecular Imaging.

  9. Quantifying the importance of MSP1-19 as a target of growth-inhibitory and protective antibodies against Plasmodium falciparum in humans.

    Directory of Open Access Journals (Sweden)

    Danny W Wilson

    Full Text Available BACKGROUND: Antibodies targeting blood stage antigens are important in protection against malaria, but the key targets and mechanisms of immunity are not well understood. Merozoite surface protein 1 (MSP1 is an abundant and essential protein. The C-terminal 19 kDa region (MSP1-19 is regarded as a promising vaccine candidate and may also be an important target of immunity. METHODOLOGY/FINDINGS: Growth inhibitory antibodies against asexual-stage parasites and IgG to recombinant MSP1-19 were measured in plasma samples from a longitudinal cohort of 206 children in Papua New Guinea. Differential inhibition by samples of mutant P. falciparum lines that expressed either the P. falciparum or P. chabaudi form of MSP1-19 were used to quantify MSP1-19 specific growth-inhibitory antibodies. The great majority of children had detectable IgG to MSP1-19, and high levels of IgG were significantly associated with a reduced risk of symptomatic P. falciparum malaria during the 6-month follow-up period. However, there was little evidence of PfMSP1-19 specific growth inhibition by plasma samples from children. Similar results were found when testing non-dialysed or dialysed plasma, or purified antibodies, or when measuring growth inhibition in flow cytometry or microscopy-based assays. Rabbit antisera generated by immunization with recombinant MSP1-19 demonstrated strong MSP1-19 specific growth-inhibitory activity, which appeared to be due to much higher antibody levels than human samples; antibody avidity was similar between rabbit antisera and human plasma. CONCLUSIONS/SIGNIFICANCE: These data suggest that MSP1-19 is not a major target of growth inhibitory antibodies and that the protective effects of antibodies to MSP1-19 are not due to growth inhibitory activity, but may instead be mediated by other mechanisms. Alternatively, antibodies to MSP1-19 may act as a marker of protective immunity.

  10. The gel generator project: the prospectus of a development program in which the gel generator is assessed as a suitable source of technetium-99m in clinical nuclear medicine

    International Nuclear Information System (INIS)

    Boyd, R.E.

    1987-02-01

    An overview is presented of the gel generator project based on the neutron activation of molybdenum. It operates through the simple technique of column elution, and the separated Tc-99m is not contaminated with undesirable radioactive or chemical impurities. The principles behind technetium generators are discussed, and publications and patents applying to the gel generator are listed

  11. Granulocyte-Macrophage Colony-Stimulating Factor Gene-Modified Vaccines for Immunotherapy of Cancer

    Czech Academy of Sciences Publication Activity Database

    Bubeník, Jan

    1999-01-01

    Roč. 45, č. 4 (1999), s. 115-119 ISSN 0015-5500 R&D Projects: GA MZd NC45011; GA MZd NC5526; GA ČR GA312/98/0826; GA ČR GA312/99/0542 Institutional research plan: CEZ:AV0Z5052915 Subject RIV: EB - Genetics ; Molecular Biology Impact factor: 0.493, year: 1999

  12. Application of 99mTc-MIBI myocardial tomography imaging for the diagnosis of coronary heart disease

    International Nuclear Information System (INIS)

    Wu Kegui; Chen Daguang; Chen Jinshui

    1992-01-01

    99m Tc-MIBI myocardial tomography imaging was obtained from 119 cases with Sopha Medical SPECT system. 38 cases of coronary heart diseases, 33 cases of coronary heart diseases combined with hypertension and 48 cases of myocardial infarction were diagnosed according to clinical symptoms and signs, ECG, exercise ECG (treadmill test) and other laboratory studies. The results showed that positive rate of myocardial thermography imaging for detecting coronary heart disease was 70.21% at rest, and the positivity can be further increased by myocardial tomography imaging with exercise test. On the contrary the positivity of exercise ECG was only 63.8%. It was concluded that radionuclide myocardial tomography imaging was noninvasive and more sensitive and specific than the exercise ECG in detecting coronary heart disease

  13. Nanostructured metal oxides: promise opportunity and challenge to develop clinically useful 99Mo/99mTc generators using (n, gamma)99Mo

    International Nuclear Information System (INIS)

    Dash, Ashutosh

    2014-01-01

    The role of 99m Tc diagnostic nuclear medicine needs hardly to be reiterated. Today, it is the most widely used radionuclide for single photon emission computed tomography (SPECT) imaging procedures. The current strategy of availing 99m Tc is ensured from column chromatographic 99 Mo/ 99m Tc generators using a bed of acidic alumina. While the column chromatographic 99 Mo/ 99m Tc generator constitute a successful exemplar of availing 99m Tc, the limited capacity of alumina (2-20 mg Mo per g of alumina) for taking up molybdate ions necessitates the use of 99 Mo of the highest specific activity available, as can be found in fission produced 99 Mo (F 99 Mo). In order to reduce dependence of F 99 Mo, the scope of using low specific activity (n,γ) 99 Mo along with high capacity adsorbent is an interesting prospect. In this context, the scope of using nanomaterials as a viable adsorbent seemed attractive by virtue of their huge surface to volume ratios, altered physical properties, tailored surface chemistry, favorable adsorption characteristics, and enhanced surface reactivity resulting from the nanoscale dimensions. This emerging class of adsorbent represents an innovative paradigm and is expected to play an important role in the development of 99 Mo/ 99m Tc generators adaptable to the existing and foreseeable demands. This talk outlines a critical assessment on the role of nanostructured metal oxides, recent developments, the contemporary status, and key challenges and apertures to the near future. (author)

  14. Feasibility study of Pridneprovskaya Thermal Power Plant reconstruction project

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2001-03-01

    With objectives of saving energy and reducing greenhouse gas emission at the Pridneprovskaya power plant in Ukraine, a scrap and build project has been discussed. This project will abolish the unit No.12 among the eight units in the existing coal burning power generation facilities, and install a natural gas burning combined cycle plant comprising of three units each with an output of 100 MW. The new plant facilities will consist of gas turbines, steam turbines, HRSG and auxiliary devices, and an air-cooled synchronous power generator with a capacity of 119 MVA. Use of natural gas as fuel reduces generation of soot, sulfur oxides, nitrogen oxides, and CO. In addition, the hot effluent and waste liquor effluent will decrease from those at the present plant. The required fund will be 30,107 million yen. The energy saving effect of this project is reduction of about 7.5 million tons of crude oil equivalent as a total in 40 years. The greenhouse effect gas will decrease by about 39 million tons as a total in 40 years. The profitability estimation calls for the number of investment recovery year of 16 years, and internal profit rate of 7.32%, wherein the implementation of the project cannot be expected as a project to be carried out by private funds. (NEDO)

  15. 30 CFR 250.119 - Will MMS approve subsurface gas storage?

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 2 2010-07-01 2010-07-01 false Will MMS approve subsurface gas storage? 250....119 Will MMS approve subsurface gas storage? The Regional Supervisor may authorize subsurface storage of gas on the OCS, on and off-lease, for later commercial benefit. To receive MMS approval you must...

  16. Decay of 99Mo

    International Nuclear Information System (INIS)

    Dickens, J.K.; Love, T.A.

    1976-01-01

    Relative intensities for K x-rays and gamma rays emanating from 99 Mo in equilibrium with its 99 Tc* daughter have been measured using several Ge photon detectors. Combining these intensities with an evaluated set of electron-conversion coefficients has provided a set of absolute intensities for the observed gamma rays. The absolute intensity for the dominant 140.5-keV gamma ray in 99 Tc was determined to be 90.7 +- 0.6/100 99 Mo disintegrations for 99 Mo decay in equilibrium with decay of the 99 Tc* daughter

  17. Modern (1992–2011) and projected (2012–99) peak snowpack and May–July runoff for the Fort Peck Lake and Lake Sakakawea watersheds in the Upper Missouri River Basin

    Science.gov (United States)

    Stamm, John F.; Todey, Dennis; Mayes Bousted, Barbara; Rossi, Shawn; Norton, Parker A.; Carter, Janet M.

    2016-02-09

    Mountain snowpack is an important contributor to runoff in the Upper Missouri River Basin; for example, high amounts of winter and spring precipitation in the mountains and plains in 2010–11 were associated with the peak runoff of record in 2011 in the Upper Missouri River Basin. To project trends in peak mountain snowpack and runoff in the upcoming decades, multiple linear regression models of peak mountain snowpack and total May–July runoff were developed for the Fort Peck Lake (above Fort Peck Dam) and lower Lake Sakakawea watersheds (between Fort Peck and Garrison Dams) in the Upper Missouri River Basin. Input to regression models included seasonal estimates of precipitation, air temperature, and total reference evapotranspiration stratified by elevation. Calibration was based on records from 107 weather stations from 1991 to 2011. Regressed annual peak mountain snowpack was used as input to the transfer function of May–July runoff. Peak snowpack and May–July runoff were projected for 2012–99 on the basis of air temperature and precipitation from the Community Climate System Model (CCSM) output. Two estimates of projected peak snowpack and May–July runoff for 2012–99 were computed: one estimate was based on output from the CCSM, version 3.0 (CCSM3), and the second estimate was based on output from the CCSM, version 4.0 (CCSM4). The significance of projected trends was based on the Kendall’s tau nonparametric test.

  18. Comparative study of {sup 99}Mo/{sup 99m}Tc generators at base of synthesized gels starting from activation and fission {sup 99}Mo; Estudio comparativo de generadores {sup 99}Mo/{sup 99m}Tc a base de geles sintetizados a partir de {sup 99}Mo de activacion y de fision

    Energy Technology Data Exchange (ETDEWEB)

    Lopez M, I Z [UAEM, Paseo Colon esq. Paseo Tollocan, 50120 Toluca, Estado de Mexico (Mexico); Monroy G, F; Rivero G, T; Rojas N, P [ININ, Carretera Mexico -Toluca S/N, 52045 La Marquesa Ocoyoacac, Estado de Mexico (Mexico)

    2007-07-01

    The {sup 99m}Tc is used for diagnostic and therapy. It is produced starting from {sup 99}Mo, absorbed in chromatographic columns, loaded with alumina that absorb only 0.2% of {sup 99}Mo with high specific activities of {sup 99}Mo, obtained from the {sup 235}U fission. Given these conditions and limitations, new preparation procedures of {sup 99}Mo/{sup 99m}Tc generators, its have been developed, using zirconium molybdates gels that incorporates until 30% of {sup 99}Mo, conserve similar characteristics of quality and purity that the traditional generator. The radiochemical characteristics of the {sup 99m}Tc elution, depend strongly on the gel preparation conditions. In particular, the present work has by object to determine the influence of the {sup 99}Mo used type, fission or activation product, during the gels synthesis, as well as the used air flow for the agitation in the gels preparation and its influence in the {sup 99}Mo/{sup 99m}Tc generators quality. When diminishing the flow of agitation air the efficiency it increases and in the radionuclide purity of the eluates and when using {sup 99}Mo from fission for the gels production it increases in an important way the elutriation efficiency, the radiochemical and radionuclide purity of the {sup 99m}Tc eluates. (Author)

  19. Results of regular study on radionuclidic purity of sup(99m)Tc obtained from 99Mo-sup(99m)Tc generators

    International Nuclear Information System (INIS)

    Vlcek, J.; Rohacek, J.; Husak, V.

    1979-01-01

    A total of 39 sup(99m)Tc eluates obtained from 9 99 Mo-sup(99m)Tc generators delivered by The Radiochemical Centre Amersham during one year was studied with regard to their radionuclide purity. Using a Ge(Li) spectrometer the contaminants 60 Co, 103 Ru, 131 I, 134 Cs, 140 La and 188 Re were found in sup(99m)Tc-eluates with average levels ranging from 2.9 x 10 -3 to 2.8 x 10 -1 per cent of sup(99m)Tc activity. The additional total body absorbed dose caused by these contaminants, as calculated from their average content in sup(99m)Tc eluates, was less than 1% of the dose due to sup(99m)Tc pertechnetate. (orig.) 891 MG/orig. 892 CS [de

  20. Lifetime Measurement in the Yrast Band of 119I

    Science.gov (United States)

    Lobach, Yu. N.; Pasternak, A. A.; Srebrny, J.; Droste, Ch.; Hagemann, G. B.; Juutinen, S.; Morek, T.; Piiparinen, M.; Podsvirova, E. O.; Toermaenen, S.; Starosta, K.; Virtanen, A.; Wasilewski, A. A.

    1999-05-01

    The lifetime of levels in the yrast band of 119I were measured by DSAM and RDM using the 109Ag (13C,3n) reaction at E=54 MeV. The detailed description of data analysis including the stopping power determination and estimation of side feeding time is given. A modified method of RDM data analysis --- Recoil Distance Doppler Shape Attenuation (RDDSA) is used.

  1. Lifetime measurement in the yrast band of 119I

    International Nuclear Information System (INIS)

    Lobach, Yu.N.; Pasternak, A.A.; Srebrny, J.

    1999-01-01

    The lifetime of levels in the yrast band of 119 I were measured by DSAM and RDM using the 109 Ag( 13 C,3n) reaction at E = 54 MeV. The detailed description of data analysis including the stopping power determination and estimation of side feeding time is given. A modified method of RDM data analysis - Recoil Distance Doppler Shape Attenuation (RDDSA) is used. (author)

  2. Radionuclidic contamination of 99Mo, 131I and 103Ru in the eluate of 99Mo-99mTc chromatographic generator: comparision on fission produced 99Mo from RPC, Nordio and ARI

    International Nuclear Information System (INIS)

    Soenarjo, Sunarhadijoso; Gunawan, Adang Hardi

    1996-01-01

    The 99 Mo- 99m Tc Chromatographic generators is the most popular system to provide 99m Tc medical radioisotope. Radioisotope Production Centre (RPC)- BATAN has routinely produced the generator loaded with 99 Mo prepared by 235 U fission. By using fission produced 99 Mo, the resulting 99m Tc is potentially contaminated by other fission products which are difficult to eliminate completely. In order to study the characteristic of the generator and radionuclidic impurity pattern of the 99m Tc eluates, an evaluation of gamma spectrometric determination has been carried out. The bulk solutions of 99 Mo produced by RPC BATAN (Indonesia), Nordion (Canada) and ARI (Australia) were loaded to generators manufactured between July 1993 to May 1994. The saline-eluate 99m Tc, in a total volume of 10 ml each, was subjected to gamma spectrometric determination. The radiation of 99m Tc was eliminated by lead shield of 0.6913 cm thickness. The 99m Tc yield fluctuation from 28 generators indicated that the characteristics of the generator columns were very good. The 99m Tc eluates were consistently contaminated by 99 Mo, 131 I and 103 Ru, although the contamination level in all cases did not exceed the maximum permissible levels. The fluctuation of radionuclidic impurities were probably caused by variation in the irradiation parameter or by variation in the 99 Mo separation methods. (author), 23 refs, 1 tab, 3 figs

  3. Pion-induced fission of 209Bi and 119Sn: measurements, calculations, analyses and comparison

    International Nuclear Information System (INIS)

    Rana, M.A.; Sher, G.; Manzoor, S.; Shehzad, M.I.

    2011-01-01

    Cross-sections for the π - -induced fission of 209 Bi and 119 Sn have been measured using the most sensitive CR-39 solid-state nuclear track detector. In experiments, target–detector stacks were exposed to negative pions of energy 500, 672, 1068, and 1665 MeV at the Brookhaven National Laboratory, USA. An important aspect of the present paper is the comparison of pion-induced fission fragment spectra of above mentioned nuclei with the spontaneous fission fragment spectra of 252 Cf. This comparison is made in terms of fission fragment track lengths in the CR-39 detectors. Measurement results are compared with calculations of Monte Carlo and statistical weight functions methods using the computer code CEM95. Agreement between measurements and calculations is fairly good for 209 Bi target nuclei whereas it is indigent for the case of 119 Sn. The possibilities of the trustworthy calculations, using the computer code CEM95, comparable with measurements of pion-induced fission in intermediate and heavy nuclei are explored by employing various systematics available in the code. Energy dependence of pion-induced fission in 119 Sn and 209 Bi is analyzed employing a newly defined parameter geometric-size-normalized fission cross-section (χ f g ). It is found that the collective nuclear excitations, which may lead to fission, become more probable for both 209 Bi and 119 Sn nuclei with increasing energy of negative pions from 500 to 1665 MeV. (author)

  4. Regional differences between 99mTc-ECD and 99mTc-HMPAO SPET in perfusion changes with age and gender in healthy adults

    International Nuclear Information System (INIS)

    Inoue, Kentaro; Nakagawa, Manabu; Goto, Ryoi; Kinomura, Shigeo; Sato, Tachio; Sato, Kazunori; Fukuda, Hiroshi

    2003-01-01

    A number of studies using single-photon emission tomography (SPET) have shown perfusion changes with age in several cortical and subcortical areas, which might distort the results of perfusion imaging studies of neuropsychiatric disorders. Technetium-99m labelled ethyl cysteinate dimer (ECD) and hexamethylpropylene amine oxime (HMPAO) are both used as markers of cerebral perfusion, but have different pharmacokinetics and retention patterns. The aim of this study was to determine whether age and gender effects on perfusion SPET differ depending on whether 99m Tc-HMPAO or 99m Tc-ECD is used. Forty-five subjects (20 male and 25 female, mean age 52.8±6.6 years) were assigned to 99m Tc-HMPAO SPET (HMPAO group), and 39 subjects (24 male and 15 female, mean age 52.6±6.7 years) to 99m Tc-ECD SPET (ECD group). SPET images were obtained about 10 min after intravenous injection of approximately 800 MBq 99m Tc-HMPAO or 99m Tc-ECD using the same SPET scanner. Three-dimensional volumetric magnetic resonance imaging was performed to as7sess morphological changes in the grey matter. All image processing and statistical analyses were performed using SPM99 software. An area in the right anterior frontal lobe showed an increase in perfusion with age only in the HMPAO group, whereas areas in the bilateral retrosplenial cortex showed decreases in perfusion with age only in the ECD group; neither group showed corresponding changes in the grey matter. The present study shows that different effects of age on perfusion are observed depending on whether 99m Tc-HMPAO and 99m Tc-ECD is used. This suggests that the results of perfusion SPET are differently confounded depending on the tracer used, and that perfusion SPET with these tracers has limitations when used in research on subtle perfusion changes. (orig.)

  5. Development of 119Sn nuclear resonance scattering of synchrotron radiation and first applications

    International Nuclear Information System (INIS)

    Barla, A.

    2001-01-01

    In the framework of this thesis the NRS technique has been developed and applied, for the first time at the European Synchrotron Radiation Facility, at the resonance of 119 Sn. Elastic nuclear forward scattering (NFS) is ideal for studies of hyperfine interactions, where information about the electronic and magnetic properties of solids is obtained. On the other hand nuclear inelastic scattering (NIS) allows one to study the phonon density of states (DOS) of Moessbauer isotopes in various kinds of systems. In the first stage, technical developments have been made, particularly with regards the used optical elements. A key point has been the construction of a high resolution monochromator (HRM) for the resonance of 119 Sn, with an energy resolution of about 0.65 meV, perfectly suited to perform NIS experiments. A second HRM optimised in throughput has been constructed and used, in combination with focussing elements (bent crystals and compound refractive lenses), to perform NFS experiments at very high pressure. For the first applications of 119 Sn NIS, the phonon DOS of β-Sn has been directly determined from the NIS spectra measured at T = 100 K and T = 300 K. An excellent agreement has been found with the phonon DOS obtained theoretically by previous calculations. Moreover, dynamical and thermodynamical properties of β-Sn extracted from the determined DOS, such as the Lamb-Moessbauer factor and the specific heat, are found to be in good agreement with previously published results. As a first application of 119 Sn NFS experiments at high pressure, the system U(In 1-x Sn x ) 3 has been chosen. (orig.)

  6. 29 CFR 4.119 - Contracts for services of communications companies.

    Science.gov (United States)

    2010-07-01

    ... Application of the McNamara-O'Hara Service Contract Act Specific Exclusions § 4.119 Contracts for services of communications companies. The Act, in paragraph (4) of section 7, exempts from its provisions “any contract for... Communications Act of 1934.” This exemption is applicable to contracts with such companies for communication...

  7. 14 CFR 119.3 - Definitions.

    Science.gov (United States)

    2010-01-01

    ...) cockpit evaluator performing the duties specified in Public Law 99-661 when the evaluator is flying on an... of all fixed ballast, unusable fuel supply, undrainable oil, total quantity of engine coolant, and... specifications, i.e., domestic, flag, supplemental, commuter, or on-demand operations. Maximum payload capacity...

  8. '99Mo/99mTc Generator Based on High Radionuclidic Pure Zirconium Molybdate Gel

    International Nuclear Information System (INIS)

    Amin, M.; Mostafa, M.; El-Amir, M.A.; El-Absy, M.A.; Mohamed, O.I.; Farag, A.B.

    2014-01-01

    99 Mo / 99 mTc radioisotope generator was prepared using in-situ precipitated zirconium molybdate chromatographic column. Zirconium molybdate gel matrix was synthesized by precipitation of neutron activation molybdenum-99 from its solution after variety purification processes to prevent contamination of the 99m Tc eluate with cross-contaminants. Greeter than 82.7 ± 0.4 % of the generated 99m Tc was immediately and reproducible eluted by passing 10 ml 0.9 % NaCl solution through the 1 g zirconium molybdate- 99 Mo column matrix at a flow rate of 0.5 ml / min and room temperature with high chemical, radionuclide ( ≥ 99.9 % 99m Tc) and radiochemical purity ( ≥ 97.7 % % as 99 mTcO 4 - ) with ph value suitable for medical uses.

  9. Magnesium-Molybate Compounds as Matrix for 99Mo/99mTc Generators

    Directory of Open Access Journals (Sweden)

    Fabiola Monroy-Guzman

    2011-01-01

    Full Text Available This work reports the preparation of a 99mTc generator based on conversion of 99Mo produced by neutron irradiation, into insoluble magnesium 99Mo-molybdates compounds as matrix. The effect of magnesium salt types and concentration, Mg:Mo molar ratios, pH of molybdate solutions, eluate volume as well as the addition order of molybdate and magnesium solutions’ influences on the final 99mTc were evaluated. Polymetalates and polymolybdates salts either crystallized or amorphous were obtained depending on the magnesium salt and Mg:Mo molar ratio used in matrix preparation. 99Mo/99mTc generator production based on magnesium-99Mo molybdate compounds allow reduction of preparation time and eliminates the use of specialized installations. The best generator performances were attained using matrices prepared from 0.1 mol/L MgCl2·6H2O solutions, ammonium molybdate solutions at pH 7 and at a Mg:Mo molar ratio of 1:1.

  10. Radionuclide Basics: Technetium-99

    Science.gov (United States)

    Technetium-99 (chemical symbol Tc-99) is a silver-gray, radioactive metal. It occurs naturally in very small amounts in the earth's crust, but is primarily man-made. Technetium-99m is a short-lived form of Tc-99 that is used as a medical diagnostic tool.

  11. 99Mo-99mTc generator - study of their performance and quality

    International Nuclear Information System (INIS)

    Acar, M.E.D.

    1987-01-01

    In this work the performance of the 99 Mo - 99m Tc generators produced at IPEN-CNEN/SP as well as the quality of the eluted solutions were analysed. The following parameters were studied: elution efficiency, chemical radiochemical, radionuclidic and microbiological purities and pH of the eluates. The 99m Tc yield ranged from 84,7 to 98,5%. The radioactivity due to the pertechnetate ion in the studied solutions was higher than 97,5%. The aluminium content in eluates, determined by spectrophotometry, was lower than 2,5 μg/ml and the pH of the solutions between 4,5 and 5,1. Radioactive impurities of the order of 10 -3 KBq 99 Mc/MBq 99m Tc and 10 -5 KBq 131 I/MBq 99m Tc were found in the eluates at the time of elution. Other γ emitting radioactive impurities were order of 10 -3 KBq/MBq 99m Tc. The eluates were sterile and pyrogen-free. From the results obtained in this work one can state that the IPEN-TEC generator is a reliable source of good quality 99m Tc-pertechnetate. (author) [pt

  12. 99Mo production by 100Mo(n,2n)99Mo using accelerator neutrons

    International Nuclear Information System (INIS)

    Sato, Nozomi; Kawabata, Masako; Nagai, Yasuki; Hashimoto, Kazuyuki; Hatsukawa, Yuichi; Saeki, Hideya; Motoishi, Shoji; Kin, Tadahiro; Konno, Chikara; Ochiai, Kentaro; Takakura, Kosuke; Minato, Futoshi; Iwamoto, Osamu; Iwamoto, Nobuyuki; Hashimoto, Shintaro

    2013-01-01

    We proposed a new route to produce a medical radioisotope 99 Mo by the 100 Mo(n,2n) 99 Mo reaction using accelerator neutrons. A high-quality 99 Mo with a minimum level of radioactive waste can be obtained by the proposed reaction. The decay product of 99 Mo, 99m Tc, is separated from 99 Mo by the sublimation method. The proposed route could bring a major breakthrough in the solution of ensuring a constant and reliable supply of 99 Mo. (author)

  13. Present status of Mo-99/Tc-99m generator in Thailand

    International Nuclear Information System (INIS)

    Khongpetch, Pranom

    2007-01-01

    Isotop Production Program, Office of Atoms for Peace had produced technetium-99m by MEK extraction of Mo-99 obtained from (n,γ) reaction in TRIGA Mark III reactor and supplied to nuclear medicine centers in Bangkok from 1980 to 1997. Because of the difficulty to meet the increased demand and limitation of reactor operation, the production of technetium-99m was stopped in 1997. Presently, there are 21 nuclear medicine centers with 25 SPECT, 7 gamma camera and 3 PET. All nuclear medicine centers are currently using imported Tc-99m generator. (author)

  14. Quality control studies of 99Mo used in 99Mo/99mTc generators produced at IPEN/CNEN-SP, Brazil

    International Nuclear Information System (INIS)

    Said, Daphne S.; Brambilla, Tania P.; Matsuda, Margareth M.N.; Osso Junior, Joao A.

    2015-01-01

    99m Tc is the most used radionuclide in nuclear medicine. In Brazil, the 99 Mo/ 99m Tc generators are produced exclusively by the Center of Radiopharmacy at IPEN-CNEN/SP, by importing 99 Mo from different suppliers. 99 Mo (t 1/2 = 66 h) is a fission product of 235 U, therefore, it can be accompanied by several radioisotopes that are highly prejudicial for human health, demanding a strict quality control of this product for generators safe use. The European Pharmacopoeia established some parameters and limits that evaluate the quality of the solution of sodium [ 99 Mo]molybdate, that is used as raw material for generator's production. The European Pharmacopoeia also recommends some analytical methods to perform these evaluations, however, it has been observed difficulties on the implementation of these methods by the generator's producers. These difficulties are probably related to the lack of practicability of the proposed methods and the extensive list of utilized reagents. In this work some procedures of the European Pharmacopoeia's quality control method for 99 Mo were evaluated. Different types of solid phase exchanger cartridges were tested for retention of 99 Mo in 3 different conditions. Cartridges that presented percentages of retention higher than 90% were also tested for separation of 99 Mo from possible contaminants (Ru e Te). The results shown that solid phase exchanger cartridges that presented percentages of retention of Mo higher than 90% also presented significant percentages of retention of Ru and Te. An alternative method for separation of 99 Mo from 131 I (other contaminant) are also proposed. (author)

  15. Near East/North Africa Report, Number 2603

    Science.gov (United States)

    1982-08-17

    Electricity Stations 118 Gum Arabic Belt 118 Popular Development 118 Foreign Exchange Regulating Measures 118 Tombura on HEC Policy 119...Middle East and that this underlines the need for a just solution to the Palestinian problem—a solution that guar - antees the legitimate rights of the...last months of 1360. It must be noted that prices of a number of goods & services, such as cold drinks, washing powder , some cigarettes and telephone

  16. Low-activity 124I-PET/low-dose CT versus 99mTc-pertechnetate planar scintigraphy or 99mTc-pertechnetate single-photon emission computed tomography of the thyroid: a pilot comparison.

    Science.gov (United States)

    Darr, Andreas M; Opfermann, Thomas; Niksch, Tobias; Driesch, Dominik; Marlowe, Robert J; Freesmeyer, Martin

    2013-10-01

    The standard thyroid functional imaging method, 99mTc-pertechnetate (99mTc-PT) planar scintigraphy, has technical drawbacks decreasing its sensitivity in detecting nodules or anatomical pathology. 124I-PET, lacking these disadvantages and allowing simultaneous CT, may have greater sensitivity for these purposes. We performed a blinded pilot comparison of 124I-PET(/CT) versus 99mTc-PT planar scintigraphy or its cross-sectional enhancement, 99mTc-PT single-photon emission CT (SPECT), in characterizing the thyroid gland with benign disease. Twenty-one consecutive adults with goiter underwent low-activity (1 MBq/0.027 mCi) 124I-PET/low-dose (30 mAs) CT, 99mTc-PT planar scintigraphy, and 99mTc-PT-SPECT. Endpoints included the numbers of “hot spots” with/without central photopenia and “cold spots” detected, the proportion of these lesions with morphological correlates, the mean volume and diameter of visualized nodules, and the number of cases of lobus pyramidalis or retrosternal thyroid tissue identified. 124I-PET detected significantly more “hot spots” with/without central photopenia (P < 0.001), significantly more nodules (P < 0.001), and more “cold spots” than did 99mTc-PT planar scintigraphy or 99mTc-PT-SPECT, including all lesions seen on the 99mTc-PT modalities. Ultrasonographic correlates were found for all nodules visualized on all 3 modalities and 92.5% of nodules seen only on 124I-PET. Nodules discernible only on 124I-PET had significantly smaller mean volume or diameter (P < 0.001) than did those visualized on 99mTc-PT planar scintigraphy or 99mTc-PT-SPECT. 124I-PET(/CT) identified significantly more patients with a lobus pyramidalis (P < 0.001) or retrosternal thyroid tissue (P < 0.05). 124I-PET(/CT) may provide superior imaging of benign thyroid disease compared to planar or cross-sectional 99mTc-PT scintigraphy.

  17. Number projected statistics and the pairing correlations at high excitation energies

    International Nuclear Information System (INIS)

    Esebbag, C.; Egido, J.L.

    1993-01-01

    We analyze the use of particle-number projected statistics (PNPS) as an effective way to include the quantum and statistical fluctuations, associated with the pairing degree of freedom, left out in finite-temperature mean-field theories. As a numerical application the exact-soluble degenerate model is worked out. In particular, we find that the sharp temperature-induced superfluid-normal phase transition, predicted in the mean-field approximations, is washed out in the PNPS. Some approximations as well as the Landau prescription to include statistical fluctuations are also discussed. We find that the Landau prescription provides a reasonable approximation to the PNPS. (orig.)

  18. 16 CFR 1.19 - Modification of a rule by the Commission at the time of judicial review.

    Science.gov (United States)

    2010-01-01

    ... 16 Commercial Practices 1 2010-01-01 2010-01-01 false Modification of a rule by the Commission at the time of judicial review. 1.19 Section 1.19 Commercial Practices FEDERAL TRADE COMMISSION... event that a reviewing court determines under section 18(e)(2) of the Federal Trade Commission Act, to...

  19. 49 CFR 1242.33 - Other expenses and casualties and insurance (accounts XX-17-99, XX-18-99, XX-19-99, 50-17-00, 50...

    Science.gov (United States)

    2010-10-01

    ... (accounts XX-17-99, XX-18-99, XX-19-99, 50-17-00, 50-18-00, and 50-19-00). 1242.33 Section 1242.33....33 Other expenses and casualties and insurance (accounts XX-17-99, XX-18-99, XX-19-99, 50-17-00, 50... separation of administrative—other (account XX-19-06). Operating Expenses—Equipment locomotives ...

  20. Chemistry and biology of Tc-99m renal function agents. Final report

    International Nuclear Information System (INIS)

    Fritzberg, A.M.

    1986-01-01

    A major aim of the project was to develop a Tc-99m renal tubular function radiopharmaceutical. Progress was made in synthesizing and evaluating Tc-99m 2,3-dimercaptoaceta-midoprepanoate (CO 2 DADS). In animals and clinical studies the A epimer (early component on reversed phase HPLC) demonstrated high efficiency and specificity for renal tubular secretion. We were unable to obtain only the desired stereoisomer. Synthesis of about twenty diamide dimercaptide N 2 S 2 ligand analogs suggested two others that were of comparable efficiency in humans, but with less difference between stereoisomers; Tc-99m 1,3-dimercaptoacetamide-2-hydroxypropane (HoDADS) and 1,8-dithiol- 2,7-dioxo-3,6-diazanonanoate (α -S-CO 2 DADS). 15 refs

  1. Local confidence limits for IMRT and VMAT techniques: a study based on TG119 test suite

    International Nuclear Information System (INIS)

    Thomas, M.; Chandroth, M.

    2014-01-01

    The aim of this study was to generate a local confidence limit (CL) for intensity modulated radiation therapy (IMRT) and volumetric modulated arc therapy (VMAT) techniques used at Waikato Regional Cancer Centre. This work was carried out based on the American Association of Physicists in Medicine (AAPM) Task Group (TG) 119 report. The AAPM TG 119 report recommends CLs as a bench mark for IMRT commissioning and delivery based on its multiple institutions planning and dosimetry comparisons. In this study the locally obtained CLs were compared to TG119 benchmarks. Furthermore, the same bench mark was used to test the capabilities and quality of the VMAT technique in our clinic. The TG 119 test suite consists of two primary and four clinical tests for evaluating the accuracy of IMRT planning and dose delivery systems. Pre defined structure sets contoured on computed tomography images were downloaded from AAPM website and were transferred to a locally designed phantom. For each test case two plans were generated using IMRT and VMAT optimisation. Dose prescriptions and planning objectives recommended by TG119 report were followed to generate the test plans in Eclipse Treatment Planning System. For each plan the point dose measurements were done using an ion chamber at high dose and low dose regions. The planar dose distribution was analysed for percentage of points passing the gamma criteria of 3 %/3 mm, for both the composite plan and individual fields of each plan. The CLs were generated based on the results from the gamma analysis and point dose measurements. For IMRT plans, the CLs obtained were (1) from point dose measurements: 2.49 % at high dose region and 2.95 % for the low dose region (2) from gamma analysis: 2.12 % for individual fields and 5.9 % for the composite plan. For VMAT plans, the CLs obtained were (1) from point dose measurements: 2.56 % at high dose region and 2.6 % for the low dose region (2) from gamma analysis: 1.46 % for individual fields and 0

  2. Magnetism of DyMn2 and HoMn2 - 57Fe and 119Sn Moessbauer studies

    International Nuclear Information System (INIS)

    Krop, K.; Haeufler, T.; Hilscher, G.; Steiner, W.

    1995-01-01

    Moessbauer spectra were measured for two Laves phase compounds DyMn 2 and HoMn 2 in which manganese was substituted to 0.5% with 57 Fe and to 0.2% with 119 Sn. At 4.2 K the 57 Fe and 119 Sn spectra of the Dy compound were unambiguously fitted each with two Zeeman patterns (with relative contributions to the spectra 3:1) corresponding to two different Mn sites - magnetic and nonmagnetic. Transferred hyperfine fields at 119 Sn were found to be proportional to the magnetic moment of Dy and its ferromagnetic component, corroborating the magnetic structure found in neutron diffraction (ND) experiment. The same procedure was carried on with the spectra measured for the Ho compound, but the above mentioned proportionality was not found. ((orig.))

  3. Homogeneous SLOWPOKE reactors for Mo-99/Tc-99m production in North America

    Energy Technology Data Exchange (ETDEWEB)

    Hilborn, J.W., E-mail: hilbovanw@sympatico.ca [Deep River, Ontario (Canada); Bonin, H.W. [Royal Military College of Canada, Kingston, Ontario (Canada)

    2014-07-01

    The 15 month shutdown of NRU in 2009 - 2010 caused an overall isotope shortage of approximately 30%; and in North America, the annual Tc-99m demand decreased from an estimated 20 million unit doses to about 15 million unit doses. Mo-99/Tc-99m is produced from HEU targets, irradiated in NRU for 11 days, and after chemical removal of uranium it is shipped to Nordion in Kanata, Ontario. Nordion further purifies the material and sends it to Lantheus Medical Imaging in the USA for manufacture of Mo-99 generators, which are then distributed to hundreds of hospital radiopharmacies throughout North America. One other American company, Covidien, manufactures and distributes Mo-99 generators like Lantheus, but they import bulk Mo-99 from Europe or South Africa. At the hospitals, Tc-99m is chemically extracted daily from the Mo-99 generators and loaded into syringes for immediate clinical use. Fortuitously, the 66 hour half-life of Mo-99 allows the replenishment of Tc-99m in the generator over a growth period of about 20 hours; and a generator can be 'milked' daily for up to two weeks. A more efficient model is the direct production and distribution of Tc-99m unit doses to regional hospitals from 10 'industrial' radiopharmacies located at existing licensed reactor sites in North America. A 20 kW homogeneous SLOWPOKE reactor at each site would deliver 15 litres of irradiated uranyl sulphate fuel solution daily to industrial-scale hot cells for extraction of Mo-99, which would be incorporated in large Mo-99/Tc-99m generators for extraction of Tc-99m five days a week; and the Low Enriched Uranium (LEU) would be recycled. Each automated hot-cell facility would be designed to load up to 7,000 Tc-99m syringes daily, for courier delivery to all of the Nuclear Medicine hospitals within a 3 hour average range by road transport. Typically, the delivered doses would be in the range 10 to 30 mCi. Assuming an average unit dose of 25 mCi at the hospital and 5 x 52

  4. Study on keV-neutron capture cross sections and capture γ-ray spectra of 117,119Sn

    International Nuclear Information System (INIS)

    Nishiyama, J.; Igashira, M.; Ohsaki, T.; Kim, G.N.; Chung, W.C.; Ro, T.I.

    2006-01-01

    The capture cross sections and capture γ-ray spectra of 117,119 Sn were measured in an incident neutron energy region from 10 to 100 keV and at 570 keV, using a 1.5-ns pulsed neutron source by the 7 Li(p,n) 7 Be reaction and a large anti-Compton NaI(Tl) γ-ray spectrometer. A pulse-height weighting technique was applied to observed capture γ-ray pulse-height spectra to derive capture yields. The capture cross sections of 117,119 Sn were obtained with the error of about 5% by using the standard capture cross sections of 197 Au. The present cross sections were compared with previous experimental data and the evaluated values in JENDL-3.3 and ENDF/B-VI. The capture γ-ray spectra of 117,119 Sn were derived by unfolding the observed capture γ-ray pulse-height spectra. The calculations of capture cross sections and capture γ-ray spectra of 117,119 Sn were performed with the EMPIRE-II code. The calculated results were compared with the present experimental ones. (author)

  5. 29 CFR 825.119 - Leave for treatment of substance abuse.

    Science.gov (United States)

    2010-07-01

    ... 29 Labor 3 2010-07-01 2010-07-01 false Leave for treatment of substance abuse. 825.119 Section 825... Leave for treatment of substance abuse. (a) Substance abuse may be a serious health condition if the conditions of §§ 825.113 through 825.115 are met. However, FMLA leave may only be taken for treatment for...

  6. 99Mo production for using in the nuclear medicine in 99mTc generators

    International Nuclear Information System (INIS)

    Kurenkov, N.V.; Chuvilin, D.Yu.

    1999-01-01

    The review of methods and advanced technologies for obtaining 99 Mo in nuclear reactors is presented. The 99 Mo isotope is used for preparing the 99m Tc generators, widely applied in nuclear medicine. The reactor method for obtaining 99 Mo is based on the 98 Mo(n, γ) 99 Mo radiation capture reaction and 235 U fission reaction under the effect of the 235 U (n, f) 99 Mo reaction. The results of studies on obtaining 99 Mo on the charged particles accelerators, mainly, on the proton beam and under the effect of photonuclear reaction is also described. The data on the 99 Mo real consumption and forecast for its application in different regions of the world from 1994 up to 2006 are presented [ru

  7. Development of 99mTc extraction techniques from 99Mo by (n,γ) reaction

    International Nuclear Information System (INIS)

    Kimura, Akihiro; Hori, Naohiko; Tsuchiya, Kunihiko; Ishihara, Masahiro; Yamabayashi, Hisamichi; Tanase, Masakazu; Fujisaki, Saburo; Sato, Yuichi

    2010-11-01

    Investigation of production method of 99 Mo by (n, γ) reaction, where the processing is relatively simple and generating less amount of radioactive waste, is conducted in the Neutron Irradiation and Testing Reactor Center. The 99 Mo is adsorbed to highly efficient adsorbent PZC after neutron irradiation and 99m Tc is eluted. However, radioactivity concentration of the 99m Tc solution obtained from PZC column loaded with 99 Mo derived by (n, γ) method is lower than that obtained from alumina column with 99 Mo by (n, f) method due to extremely low specific activity of (n, f) 99 Mo. Therefore, it is necessary to develop technique for increasing the amount of 99 Mo and the 99m Tc solution of high radioactivity concentration (minimum: 1Ci/ cm 3 ). In this study, the preliminary fabrication tests using high density MoO 3 pellets were carried out to increase the production of 99 Mo. The method of concentrating 99m Tc solution through solvent extraction with MEK was investigated and a device for this concentration process was also developed. In the preliminary tests of the MoO 3 pellets, the pellets having high density were successfully fabricated by the SPS method. Additionally, it was ascertained that the pellets can be dissolved with 6M-NaOH solution completely. The test for 99 Mo adsorption followed by 99m Tc elution using PZC was carried out. As the result, amount of Mo adsorbed to 1g-PZC was about 250mg, and 99m Tc yield was about 80%. In the concentration test using Re solution instead of 99m Tc solution, it was ascertained that the concentration efficiency is higher than 80% of the theoretical value. A concentration device for 99m Tc solution could be realized based on the method employed in the present experiments. The outcomes of development of 99m Tc extraction techniques from 99 Mo by (n,γ) reaction was reviewed in this paper, and the contents were presented in the 3rd International Symposium on Material Test Reactors. (author)

  8. Survey and analysis of satellite-based telemedicine projects involving Japan and developing nations: investigation of transmission rates, channel numbers, and node numbers.

    Science.gov (United States)

    Nakajima, I; Natori, M; Takizawa, M; Kaihara, S

    2001-01-01

    We surveyed interactive telemedicine projects via telecommunications satellite (AMINE-PARTNERS, Post-PARTNERS, and Shinshu University Project using Inmarsat satellites) offered by Japan as assistance to developing countries. The survey helped clarify channel occupation time and data transfer rates. Using our survey results, we proposed an optimized satellite model with VSATs simulating the number of required channels and bandwidth magnitude. For future implementation of VSATs for medical use in developing nations, design of telecommunication channels should take into consideration TCP/IP-based operations. We calculated that one hub station with 30-76 VSATs in developing nation can be operated on bandwidth 6 Mbps using with 128 Kbps videoconferencing system for teleconsultation and teleconference, and linking with Internet.

  9. Study of the activation of targets containing Mo for the production of 99Mo by the 98Mo(n,γ)99Mo nuclear reaction and the behaviour of the radionuclidic impurities of the process

    International Nuclear Information System (INIS)

    Nieto, Renata Correa

    1998-01-01

    The most used radioisotope in Nuclear Medicine is 99m Tc, in the 99 Mo- 99m Tc generator form. 99 Mo can be produced by several nuclear reactions in reactors and cyclotrons. The cyclotron production is not technically and economically viable. The production in the reactor can be done in two different ways: by the fission of 235 U and by 98 Mo(n,γ) 99 Mo reaction. A project for the production of 99 Mo by the activation of Mo and the preparation of gel type generators is under development at the 'Instituto de Pesquisas Energeticas e Nucleares'. In the present work, the radionuclidic impurities produced in the activation of MOO 3 and MoZr gel were evaluated, and these represent the two possible ways of preparing the gel of MoZr. A target of metallic Mo was also studied. The radionuclidic purity of 99m Tc eluted from generators prepared in these ways was also measured and compared with the generators prepared with fission 99 Mo. The results showed that, by all the parameters analysed, the best way of preparing the generator of 99 Mo - 99m Tc is the irradiation of MOO 3 and further preparation of the gel and the generators. (author)

  10. 14 CFR 99.1 - Applicability.

    Science.gov (United States)

    2010-01-01

    ... 14 Aeronautics and Space 2 2010-01-01 2010-01-01 false Applicability. 99.1 Section 99.1... AND GENERAL OPERATING RULES SECURITY CONTROL OF AIR TRAFFIC General § 99.1 Applicability. (a) This... Identification Zone (ADIZ) designated in subpart B. (b) Except for §§ 99.7, 99.13, and 99.15 this subpart does...

  11. Use of 99mTc from a commercial 99Mo/9mTc generator as yield tracer for the determination of 99Tc at low levels

    DEFF Research Database (Denmark)

    Hou, Xiaolin; Jensen, Mikael; Nielsen, Sven Poul

    2007-01-01

    The concentrations of Tc-99 and impurity radionuclides in the Tc-99m tracer solution obtained from a commercial Mo-99/Tc-99m generator were measured by gamma spectrometry and liquid scintillation counting. Mo-99 and Ru-103 were found in the Tc-99m eluate. A simple separation using two extra alumina...... cartridges was investigated to purify the eluate to obtain a suitable Tc-99m tracer with low Tc-99 concentration. The activity ratio of Tc-99/Tc-99m in the prepared Tc-99m solution is lower than 15 x 10(-9), which is higher than the theoretical ratio of less than 10 x 10(-9). The possible reason is discussed....... The Tc-99 in the 20 kBq spiked Tc-99m tracer was found to be less than 0.3mBq, which is lower than the detection limit of the radiometric method used for environmental samples. The purified Tc-99m eluate is used as yield tracer for the determination of low levels of Tc-99 in environmental samples. (c...

  12. Adult Dyslexia and Attention Deficit Disorder in Finland--Project DyAdd: WAIS-III Cognitive Profiles

    Science.gov (United States)

    Laasonen, Marja; Leppamaki, Sami; Tani, Pekka; Hokkanen, Laura

    2009-01-01

    The project Adult Dyslexia and Attention Deficit Disorder in Finland (Project DyAdd) compares adults (n = 119, 18-55 years) with dyslexia, attention-deficit/hyperactivity disorder (ADHD), dyslexia together with ADHD (comorbid), and healthy controls with neuropsychological, psychophysical, and biological methods. The focus of this article is on the…

  13. Preparation of i.v. 99mTc radiopharmaceuticals from spent moly 99Mo

    International Nuclear Information System (INIS)

    Noronha, O.P.D.

    1998-01-01

    Full text: Expiry dating is an important quality assurance precept in (radio) pharmacy. There are occasions when for the sake of patient service one may be forced to continue using an over aged source of 99 Mo to generate 99m Tc beyond 7d, especially when there is short/no supply of 99 Mo, (In the early days the expiry date was 3 d or 3 extractions, whichever one was earlier). With the passage of time a few physico-chemical changes (apart from decay) do occur in the 99 Mo/ 99m Tc milieu. The cocktail also begins to contain traces of carried over MEK which is subjected to strong β-, γ irradiation. These impurity (in trace amounts) is soluble in MEK and even, to an extent, in aqueous media. Furthermore, the concentrated impurity tends to seemingly increase in the bulk 99m TcO 4 - since one is compelled to leach TcO 4 - in lower volume of saline. On many occasions we have been constrained to extend the use of 99 Mo beyond 7 - 14 d. Adequate activities were obtained by pooling the previous week's lot of 99 Mo with the current over aged lot. On a few occasions over the past 26 years we have used 99 Mo much beyond 14 d and 2 - 3 occasions for 26 - 28 d (i.e. >10 t 1 /2 of 99 Mo). On each of these occasions the purity of 99m TcO- 4 was ascertained by pharmacopoeial procedures. It was found that despite depleting activities, the purity was not compromised and the trace impurities, even if present, did not cause any interference. We have profitably utilised the bulk TcO- 4 to formulate a variety of i.v. dosage forms of 99m Tc radiodiagnostics. The following strategy was adopted for the patient services - the agents requiring larger activity levels/patients dose were made available in the earlier period, the other during the latter half. It is concluded that pure 99m TcO- 4 can be obtained over the entire useful life-period of 99 Mo, even > 10t l/2

  14. A comparative study of 99Tcm-tetrofosmin and 99Tcm-MIBI myocardial imaging

    International Nuclear Information System (INIS)

    Zhao Kui; Chen Peng; Zhang Furong; Shen Wenhua

    2001-01-01

    Objective: To evaluate the value of 99 Tc m -tetrofosmin myocardial imaging for detecting coronary artery disease. Methods: Twenty-seven patients underwent 99 Tc m -tetrofosmin SPECT, twenty-six patients underwent 99 Tc m -MIBI SPECT; coronary angiography was performed on patients included in both groups (≥50% luminal diameter stenosis was considered significant coronary stenosis). Results: 99 Tc m -tetrofosmin produced high quality myocardial images from 30 min to several hours postinjection, the outlines of myocardial perfusion images provided by 99 Tc m -tetrofosmin imaging were clearly discernible. One-day exercise/rest 99 Tc m -tetrofosmin myocardial perfusion imaging was feasible and had a high sensitivity for detection of coronary artery disease. Sensitivities of 99 Tc m -tetrofosmin SPECT and 99 Tc m -MIBI SPECT for detecting coronary artery disease were 90% and 94%, respectively. The 95% confidence limits of both sensitivities were 68.65% - 98.77% and 72.33% - 99.86%, respectively; the positive predictive values of both imaging agents were 90.0% and 89.5%, respectively, the 95% confidence limits of those were 68.38% - 98.77% and 72.33% - 99.86% respectively; the positive predictive values of both imaging agents were 90.0% and 89.5%, respectively, the 95% confidence limits of those were 68.38% - 98.77% and 66.38% - 98.70%, respectively; efficiencies of both imaging agents were 85.2% and 88.5%, respectively. The 95% confidence limits of both efficiencies were 65.81% - 95.78% and 69.44 - 98.70%, respectively. The specificity for both imaging agents was 71% and 75%. There was no significant difference among above results (P > 0.05). No ECG abnormalities were found following the injection of 99 Tc m -tetrofosmin SPECT. There were no drug-related effects on blood pressure, heart rate and body temperature. This experiment failed to provide the negative predictive value of the myocardial perfusion imaging with 99 Tc m -tetrofosmin because that few patients with

  15. Synthesis and characterization of zirconium molybdates of 99 Mo/99m Tc generators

    International Nuclear Information System (INIS)

    Contreras R, A.; Monroy G, F.; Diaz A, L.V.

    2002-01-01

    The zirconium molybdates are gels which are used as cation exchangers in the production of 99 Mo/ 99m Tc generators. The synthesis method and the characterization of these gels by thermogravimetry, infrared spectroscopy and X-ray diffraction is presented with the purpose of finding which the factors are that influence in the efficiency of the 99m Tc production. The results show that the quantity of molecular water contained in gel, is possibly the cause of variations of the efficiencies of the 99 Mo/ 99m Tc generator. (Author)

  16. Synthesis and characterization of zirconium molybdates of {sup 99} Mo/{sup 99m} Tc generators; Sintesis y caracterizacion de molibdatos de zirconio de generadores {sup 99} Mo/{sup 99m} Tc

    Energy Technology Data Exchange (ETDEWEB)

    Contreras R, A.; Monroy G, F.; Diaz A, L.V. [Instituto Nacional de Investigaciones Nucleares, A.P. 18-1027, 11801 Mexico D.F. (Mexico)

    2002-07-01

    The zirconium molybdates are gels which are used as cation exchangers in the production of {sup 99} Mo/{sup 99m} Tc generators. The synthesis method and the characterization of these gels by thermogravimetry, infrared spectroscopy and X-ray diffraction is presented with the purpose of finding which the factors are that influence in the efficiency of the {sup 99m} Tc production. The results show that the quantity of molecular water contained in gel, is possibly the cause of variations of the efficiencies of the {sup 99} Mo/{sup 99m} Tc generator. (Author)

  17. Recent global crisis in 99Mo production and supplies: analysis and lessons

    International Nuclear Information System (INIS)

    Ramamoorthy, Natesan; Ed Bradley; Adelfang, Pablo; )

    2011-01-01

    The radioisotope 99m Tc is a vital need for diagnostic functional imaging of organs and physiologic processes in nuclear medicine centres and hospitals all over the world. 99m Tc (6 h) is obtained from the radioactive (beta) decay of 99 Mo (66 h) and is generally availed at the user end in hospitals or radiopharmacies from a 99 Mo- 99m Tc generator, and therefore reliable weekly availability of 99 Mo of very high specific activity is essential for sustainable supplies of 99m Tc. Over the past several decades, the commercial availability of 99 Mo (mostly fission-produced) from corporate sources has been satisfactory. However, from around the end of 2007, the production and supplies of 99 Mo were severely and repeatedly affected causing worldwide concerns and led to calls for international efforts to address the security of supplies of 99 Mo and 99m Tc. Various initiatives and analytical reviews during the past two years, including at the IAEA and OECD-NEA, have revealed a number of issues and lessons learnt. Research reactor managers and their governments serving 99 Mo- 99m Tc industry have faced several challenges, technological, regulatory and economical among others, apart from the fact that these reactors are not dedicated to isotopes production. Furthermore, towards long term security of 99 Mo supplies, switch over to using LEU targets and establishing some additional processing capacity need to be addressed. Several alternative non-HEU technologies for producing 99 Mo and 99m Tc are also under consideration, including through non-fission and non-reactor based methods. The article will draw analytical conclusions and recommendations based on the available professional knowledge and experience in the field as well as from the findings reported in the recent documents and in meetings including that of the IAEA and OECD-NEA. (author)

  18. Evaluation of the absorbed dose to the kidneys due to Tc99m (DTPA) / Tc99m (Mag3) and Tc99m (Dmsa)

    International Nuclear Information System (INIS)

    Vasquez A, M.; Murillo C, F.; Castillo D, C.; Rocha J, J.; Sifuentes D, Y.; Sanchez S, P.; Idrogo C, J.; Marquez P, F.

    2015-10-01

    The absorbed dose in the kidneys of adult patients has been assessed using the biokinetics of radiopharmaceuticals containing Tc 99m (DTPA) / Tc 99m (Mag3) or Tc 99m (Dmsa).The absorbed dose was calculated using the formalism MIRD and the Cristy-Eckerman representation for the kidneys. The absorbed dose to the kidneys due to Tc 99m (DTPA) / Tc 99m (Mag3), are given by 0.00466 mGy.MBq -1 / 0.00339 mGy.MBq -1 . Approximately 21.2% of the absorbed dose is due to the bladder (content) and the remaining tissue, included in biokinetics of Tc 99m (DTPA) / Tc 99m (Mag3). The absorbed dose to the kidneys due to Tc 99m (Dmsa) is 0.17881 mGy.MBq -1 . Here, 1.7% of the absorbed dose is due to the bladder, spleen, liver and the remaining tissue, included in biokinetics of Tc 99m (Dmsa). (Author)

  19. Feasibility of Producing Molybdenum-99 on a Small Scale Using Fission of Low Enriched Uranium or Neutron Activation of Natural Molybdenum

    International Nuclear Information System (INIS)

    2015-01-01

    This publication documents the work performed within the IAEA coordinated research project (CRP) on Developing Techniques for Small Scale Indigenous Molybdenum-99 Production Using LEU Fission or Neutron Activation. The project allowed participating institutions to receive training and information on aspects necessary for starting production of molybdenum-99 ( 99 Mo) on a small scale, that is, to become national level producers of this medical isotope. Stable production of 99Mo is one of the most pressing issues facing the nuclear community at present, because the medical isotope technetium-99m ( 99m Tc), which decays from 99 Mo, is one of the most widely used radionuclides in diagnostic imaging and treatment around the world. In the past five years, there have been widespread shortages of 99 Mo owing to the limited number of producers, many of which use ageing facilities. To assist in stabilizing the production of 99Mo, and to promote the use of production methods that do not rely on the use of highly enriched uranium (HEU), the IAEA initiated the abovementioned CRP on small scale 99Mo production using low enriched uranium (LEU) fission or neutron activation methods. The intention was to enable participating institutions to gain the knowledge necessary to become national level producers of 99Mo in the event of further global shortages. Some of the institutions that participated in the CRP have continued their work on 99 Mo production, and are enlisting the assistance of other CRP members and the IAEA’s technical cooperation programme to set up a small scale production capability. In total, the CRP was active for six years, and concluded in December 2011. During the CRP, fourteen IAEA Member States took part; four research coordination meetings were held, and four workshops were held on operational aspects of 99 Mo production, LEU target fabrication and waste management. Most participants carried out work related to the entire production process, from target

  20. Interpreting ‘Torah’ in Psalm 1 in the light of Psalm 119

    Directory of Open Access Journals (Sweden)

    Philippus J. Botha

    2012-11-01

    Full Text Available This article argued that Psalm 37 and Proverbs 1–4 served as sources for the composition of Psalm 1. The emphasis in both donor texts on the righteous people’s inheriting the Promised Land seems to have imprinted also on Psalm 1, a factor that could change our understanding of it. All three contexts in turn played a role in the composition of Psalm 119, but whilst the author of this long psalm also understood the ‘Torah’ of Yahweh as the incarnation of true wisdom, it seems that ‘Torah’ also subsumed the Promised Land for him. The investigation showed that ‘Torah’ in Psalm 1 should be understood as an arch-lexeme for all the religious texts its author used to compose, similar to what was the understanding of the author of Psalm 119 a little later.

  1. The Development of “Eldo Ngano 1”: The World’s World’s First Ug99 Resistant Mutant Wheat Variety

    International Nuclear Information System (INIS)

    Forster, Brian P.

    2014-01-01

    The wheat black stem rust disease is a virulent race of fungus, Puccinia graminis, which affects wheat plants and is caused by a strain of fungus known as Ug99. Named for its place and year of origin, Ug99 was first discovered on wheat in Uganda in 1999. The spores of this plant disease are airborne and can be easily spread by wind. If not prevented, the disease can destroy 70 to 100 per cent of the yield of wheat crops. Annually on average 8.3 million tonnes of wheat grain is lost to this disease, costing US $1.23 billion per year. Ethiopia, Kenya and Uganda are hot spots for this disease. In 2009, growing international concern regarding the horrific impact of Ug99 on wheat led to the establishment of IAEA project INT/5/150, Responding to the Transboundary Threat of Wheat Black Stem Rust (Ug99). This project has involved over 18 countries and 5 national and international institutions, and examined possible mutation induction treatments to deal with the challenges posed by Ug99. Meetings and workshops to facilitate the project efforts have been held in Kenya and Turkey. Ug99 continues to spread globally and has now reached the Islamic Republic of Iran. There are also reports of suspected disease occurrences in Europe. It is essential that work continues on developing mutant lines for further crop protection that can be utilized worldwide to safeguard the wheat crop from this devastating disease

  2. Optimization of Culture Conditions for Production of the Anti-Leukemic Glutaminase Free L-Asparaginase by Newly Isolated Streptomyces olivaceus NEAE-119 Using Response Surface Methodology

    Directory of Open Access Journals (Sweden)

    Noura El-Ahmady El-Naggar

    2015-01-01

    Full Text Available Among the antitumor drugs, bacterial enzyme L-asparaginase has been employed as the most effective chemotherapeutic agent in pediatric oncotherapy especially for acute lymphoblastic leukemia. Glutaminase free L-asparaginase producing actinomycetes were isolated from soil samples collected from Egypt. Among them, a potential culture, strain NEAE-119, was selected and identified on the basis of morphological, cultural, physiological, and biochemical properties together with 16S rRNA sequence as Streptomyces olivaceus NEAE-119 and sequencing product (1509 bp was deposited in the GenBank database under accession number KJ200342. The optimization of different process parameters for L-asparaginase production by Streptomyces olivaceus NEAE-119 using Plackett-Burman experimental design and response surface methodology was carried out. Fifteen variables (temperature, pH, incubation time, inoculum size, inoculum age, agitation speed, dextrose, starch, L-asparagine, KNO3, yeast extract, K2HPO4, MgSO4·7H2O, NaCl, and FeSO4·7H2O were screened using Plackett-Burman experimental design. The most positive significant independent variables affecting enzyme production (temperature, inoculum age, and agitation speed were further optimized by the face-centered central composite design-response surface methodology.

  3. Estimated number of adults with prediabetes in the US in 2000: opportunities for prevention.

    Science.gov (United States)

    Benjamin, Stephanie M; Valdez, Rodolfo; Geiss, Linda S; Rolka, Deborah B; Narayan, K M Venkat

    2003-03-01

    To estimate the percent and number of overweight adults in the U.S. with prediabetes who would be potential candidates for diabetes prevention as per the American Diabetes Association Position Statement (12). We analyzed data from the Third National Health and Nutrition Examination Survey (NHANES III; 1988-1994) and projected our estimates to the year 2000. We defined impaired glucose tolerance (IGT; 2-h glucose 140-199 mg/dl), impaired fasting glucose (IFG; fasting glucose 110-125 mg/dl), and prediabetes (IGT or IFG) per American Diabetes Association (ADA) criteria. The ADA recently recommended that all overweight people (BMI >or=25 kg/m(2)) who are >or=45 years of age with prediabetes could be potential candidates for diabetes prevention, as could prediabetic people aged >25 years with risk factors. In NHANES III, 2-h postload glucose concentrations were done only among subjects aged 40-74 years. Because we were interested in overweight people who had both the 2-h glucose and fasting glucose tests, we limited our estimates of IGT, IFG, and prediabetes to those aged 45-74 years. RESULTS-Overall, 17.1% of overweight adults aged 45-74 years had IGT, 11.9% had IFG, 22.6% had prediabetes, and 5.6% had both IGT and IFG. Based on those data, we estimated that in the year 2000, 9.1 million overweight adults aged 45-74 had IGT, 5.8 million had IFG, 11.9 million had prediabetes, and 3.0 million had IGT and IFG. Almost 12 million overweight individuals aged 45-74 years in the U.S. may benefit from diabetes prevention interventions. The number will be substantially higher if estimation is extended to individuals aged >75 and 25-44 years.

  4. Adsorption behavior of 99Mo using AG1-X8 anionic resin

    International Nuclear Information System (INIS)

    Santos, Jacinete L. dos; Yamaura, Mitiko; Damasceno, Marcos O.; Forbicini, Christina A.L.G.O.

    2013-01-01

    The significant growth in demand of 99 Mo in developed and developing countries, like Brazil, requires large production capacity and availability of this radioisotope. With the global crisis on its supply to Brazil rethought the need to become independent in their production and the solution was to start the Brazilian Multipurpose Reactor (RMB) project, which aims to meet the national demand of 99 Mo for the medical field. This work aims to study the 99 Mo adsorption in AG1-X8 strong anion resin, which is one of the intermediate steps of separation and purification, retaining it in the form of molybdate ions. In process evaluated the resin properties with respect to pH and concentration of 99 Mo in the solution. The adsorbed amount of 99 Mo was determined indirectly by the amount in the supernatant after adsorption and the data fitted to the Langmuir and Freundlich isotherms. Among the models, the Langmuir showed a closer relationship with the experimentally obtained data. This suggests the occurrence of monolayer adsorption and heterogeneous conditions at the surface, where both phenomena can coexist in the experimental conditions tested. (author)

  5. Verification of Dosimetric Commissioning Accuracy of Intensity Modulated Radiation Therapy and Volumetric Modulated Arc Therapy Delivery using Task Group-119 Guidelines.

    Science.gov (United States)

    Kaviarasu, Karunakaran; Nambi Raj, N Arunai; Hamid, Misba; Giri Babu, A Ananda; Sreenivas, Lingampally; Murthy, Kammari Krishna

    2017-01-01

    The purpose of this study is to verify the accuracy of the commissioning of intensity-modulated radiation therapy (IMRT) and volumetric-modulated arc therapy (VMAT) based on the recommendation of the American Association of Physicists in Medicine Task Group 119 (TG-119). TG-119 proposes a set of clinical test cases to verify the accuracy of IMRT planning and delivery system. For these test cases, we generated two sets of treatment plans, the first plan using 7-9 IMRT fields and a second plan utilizing two-arc VMAT technique for both 6 MV and 15 MV photon beams. The template plans of TG-119 were optimized and calculated by Varian Eclipse Treatment Planning System (version 13.5). Dose prescription and planning objectives were set according to the TG-119 goals. The point dose (mean dose to the contoured chamber volume) at the specified positions/locations was measured using compact (CC-13) ion chamber. The composite planar dose was measured with IMatriXX Evaluation 2D array with OmniPro IMRT Software (version 1.7b). The per-field relative gamma was measured using electronic portal imaging device in a way similar to the routine pretreatment patient-specific quality assurance. Our planning results are compared with the TG-119 data. Point dose and fluence comparison data where within the acceptable confident limit. From the obtained data in this study, we conclude that the commissioning of IMRT and VMAT delivery were found within the limits of TG-119.

  6. Separation of sup(99m)Tc from 99Mo through a hydrous zirconium oxide column

    International Nuclear Information System (INIS)

    Mengatti, J.

    1980-01-01

    The preparation of 99 Mo-,sup(99m)Tc generator based on the adsorption of 99 Mo on hydrous zirconium oxide column, employing the in exchange technique, is described. The adsorption of 99 Mo on hydrous zirconium oxide (HZO) and the separation of sup(99m)Tc, generated by the decay of 99 Mo with saline solution, are analised. The sup(99m)Tc separation yield, pH of the eluted solution, aspect of the elution curve and the adsorption of 99 Mo on hydrous zirconium oxide calcined at 800 0 C are studied. The chemical and radioactive purities of the final product are analysed and the variation of the elution yield for successive elutions is studied. (Author) [pt

  7. Studies of techniques for the post-elution concentration of 99mTc obtained from gel type 99Mo/99mTc generators

    International Nuclear Information System (INIS)

    Suzuki, Katia Noriko

    2009-01-01

    On average 80% of the radiopharmaceuticals used in Nuclear Medicine are labeled with 99 mTc due to its physical properties and easy attainment through of 99 Mo/ 99 mTc generators. The Directory of Radiopharmacy (DIRF) of IPEN-CNEN/SP developed a gel type chromatographic generator of MoZr with 99 Mo produced by 98 Mo(n,γ) 99 Mo reaction that occurs at the IEA-R1 Nuclear Reactor. The gel is composed of zirconium molybdate with elution volume of 12 mL with an activity of 11100 MBq (300 mCi) producing a radioactive concentration of 925 MBq (25 mCi)/mL. The fission generator gives a higher radioactive concentration around 1850 MBq (50 mCi)/mL. The aim of this work is to study a system of post-elution concentration of 99 mTc for the attainment of a high enough radioactive concentration to meet the demands of the market, with a proved quality. Two types of systems of post-elution concentration were developed: the single and the tandem. The most appropriate system for the gel generator of 99 Mo/ 99 mTc, being at the same time sterile and vacuum automated, was the tandem system using Dionex 2.5 cc/QMA cartridges. The gel generator is eluted with 10 mL of solution of 0.1% NaCl and the pertechnetate anion is retained in the QMA cartridge and further eluted with 4 mL of saline. The process takes no more than 30 minutes. The elution efficiency of the system of concentration was 90 %. At the beginning of 2009 a global crisis in the supply of 99 Mo took place making it necessary the development of alternative technologies for the production of 99 Mo/ 99 mTc generators using fission produced 99 Mo and the development of an appropriate method to extend the useful life of this generator. The results of this study showed that the same system developed for the post- concentration of the gel generator can be employed for the fission generator, using the tandem system, giving a concentration factor of 3 for the elution of 99 mTc. (author)

  8. Development of {sup 119}Sn nuclear resonance scattering of synchrotron radiation and first applications

    Energy Technology Data Exchange (ETDEWEB)

    Barla, A.

    2001-07-01

    In the framework of this thesis the NRS technique has been developed and applied, for the first time at the European Synchrotron Radiation Facility, at the resonance of {sup 119}Sn. Elastic nuclear forward scattering (NFS) is ideal for studies of hyperfine interactions, where information about the electronic and magnetic properties of solids is obtained. On the other hand nuclear inelastic scattering (NIS) allows one to study the phonon density of states (DOS) of Moessbauer isotopes in various kinds of systems. In the first stage, technical developments have been made, particularly with regards the used optical elements. A key point has been the construction of a high resolution monochromator (HRM) for the resonance of {sup 119}Sn, with an energy resolution of about 0.65 meV, perfectly suited to perform NIS experiments. A second HRM optimised in throughput has been constructed and used, in combination with focussing elements (bent crystals and compound refractive lenses), to perform NFS experiments at very high pressure. For the first applications of {sup 119}Sn NIS, the phonon DOS of {beta}-Sn has been directly determined from the NIS spectra measured at T = 100 K and T = 300 K. An excellent agreement has been found with the phonon DOS obtained theoretically by previous calculations. Moreover, dynamical and thermodynamical properties of {beta}-Sn extracted from the determined DOS, such as the Lamb-Moessbauer factor and the specific heat, are found to be in good agreement with previously published results. As a first application of {sup 119}Sn NFS experiments at high pressure, the system U(In{sub 1-x}Sn{sub x}){sub 3} has been chosen. (orig.)

  9. The preparation of {sup 99m}Tc from {sup 99}Mo-{sup 99m}Tc using Poly-Zirconium Compound (PZC)

    Energy Technology Data Exchange (ETDEWEB)

    Laohawilai, S [Isotope Production Div., Office of Atomic Energy for Peace (Thailand)

    1998-10-01

    The process of for providing the {sup 99m}Tc-gel generator followed the protocol that received from Department of Radioisotopes, Tokai Research Establishment, JAERI. Sodium molybdate (molybdenum-99), pH 7 with concentration 20 mg/ml and activity nearly 1 mCi/ml was added into the adsorbent (PZC). The total activity of {sup 99}Mo was about 10 mCi and the heating time was varied from 3-18 hours at 70degC. The properties of the gel were studied for elution profile and elution efficiency. The molybdenum breakthrough in sodium pertechnetate (technetium-99m) was also performed. (author)

  10. Projections on the number of individuals with atrial fibrillation in the European Union, from 2000 to 2060.

    Science.gov (United States)

    Krijthe, Bouwe P; Kunst, Anton; Benjamin, Emelia J; Lip, Gregory Y H; Franco, Oscar H; Hofman, Albert; Witteman, Jacqueline C M; Stricker, Bruno H; Heeringa, Jan

    2013-09-01

    Since atrial fibrillation (AF) is associated with increased risks of cardiovascular and cerebrovascular complications, estimations on the number of individuals with AF are relevant to healthcare planning. We aimed to project the number of individuals with AF in the Netherlands and in the European Union from 2000 to 2060. Age- and sex-specific AF prevalence estimates were obtained from the prospective community-based Rotterdam Study. Population projections for the Netherlands and the European Union were obtained from the European Union's statistics office. In the age stratum of 55-59 years, the prevalence of AF was 1.3% in men (95% CI: 0.4-3.6%) and 1.7% in women (95% CI: 0.7-4.0%). The prevalence of AF increased to 24.2% in men (95% CI: 18.5-30.7%), and 16.1% in women (95% CI: 13.1-19.4%), for those >85 years of age. This age- and sex-specific prevalence remained stable during the years of follow-up. Furthermore, we estimate that in the European Union, 8.8 million adults over 55 years had AF in 2010 (95% CI: 6.5-12.3 million). We project that this number will double by 2060 to 17.9 million (95% CI: 13.6-23.7 million) if the age- and sex-specific prevalence remains stable. We estimate that from 2010 to 2060, the number of adults 55 years and over with AF in the European Union will more than double. As AF is associated with significant morbidities and mortality, this increasing number of individuals with AF may have major public health implications.

  11. Report on inter-noise 99; Inter-noise 99 sanka hokok

    Energy Technology Data Exchange (ETDEWEB)

    Koike, H. [Japan Automobile Research Institute Inc., Tsukuba (Japan)

    2000-04-01

    Inter-Noise (International Congress on Noise Control Engineering) is a society on noise/vibration and the control technology. Inter-Noise 99 was held on December 6, 7 and 8, 1999, at Fort Lauderdale, Florida, the U.S. The theme was Noise Control in the New Millennium. The number of the participants registered was 555 (151 from the U.S., 89 from Japan, 248 from European countries, and 69 from Asian/other countries). Dr. Harold Marshall gave a keynote lecture titled Noise Control by Design in the 21st Century - An Architectural Acoustic Perspective. From a standpoint of architectural acoustics, he stated the perspective, subjects, and course of the technical development pertaining to technologies needed in the 21st century. The papers read are mostly from the following fields: measuring technology, military exercise noise, modeling, forecast and simulation, aerodynamic/underwater sound, etc. In the session on the tire noise where the author read a paper, 14 papers were read. The number of the papers read was more than that in 1998, probably influenced by the tire noise regulation in Europe and Japan. (translated by NEDO)

  12. A comparative study of 99Tcm-MDP, 99Tcm(V)-DMSA and 99Tcm-Citrate in diagnosis of bone malignant tumors and bone/joint infections

    International Nuclear Information System (INIS)

    Wu Zhaozhong; Wu Boyi; Lin Wei; Wei Xueli; Wu Hengfu; Fan Ziwen; Ouyang Zhi; Wu Changwei; Yuan Gewen

    2003-01-01

    The purpose of this study was to assess the diagnostic value of scans with 99 Tc m (V)-dimercaptosuccinic acid (DMSA) to localize bone metastases and to evaluate the capability to diagnose bone/joint infections with scans using 99 Tc m -Citrate. Eighteen patients referred to bone metastases and eighteen patients referred to bone and joint infection were studied. In all patients, a bone scan of 99 Tc m -MDP was obtained initially. Subsequently, comparative scans with 99 Tc m (V)-DMSA and 99 Tc m -Citrate were conducted successively. Pathologic finding and/or microbiological finding, X-ray CT and/or MRI, and/or clinical follow-up (until symptoms disappeared) were considered to be proof of the presence of bone metastases and bone/joint infection. All of the eighteen patients with diagnosed bone metastases and of the eighteen patients with diagnosed bone and joint infection had positive 99 Tc m -MDP scintigraphy. The fifteen patients with diagnosed bone metastases and the fifteen patients with diagnosed bone/joint infection had increased 99 Tc m (V) -DMSA accumulation at certain areas matched with those shown in 99 Tc m -MDP scans, and only one patient with diagnosed bone metastases and the fifteen patients with diagnosed bone and joint infection had increased 99 Tc m -Citrate accumulation at certain areas matched with those shown in 99 Tc m -MDP scans. 99 Tc m -MDP scans show 64 bone lesions in the bone metastases while 49 lesions by the 99 Tc m (V)-DMSA scans and only one lesion by the 99 Tc m -Citrate scans respectively. And 99 Tc m -MDP scans show 22 bone lesions in the bone and joint infection while 17 lesions by the 99 Tc m (V)-DMSA imaging and 16 lesions by the 99 Tc m -Citrate imaging respectively. For bone metastases diagnosis, the sensitivity of 99 Tc m (V)-DMSA imaging and 99 Tc m -Citrate imaging were 76.56% and 1.56%, respectively, and the specificity were only 22.73% and 27.27%, respectively. For bone and joint infection diagnosis, the sensitivity of two

  13. Configuration mixing of mean-field wave functions projected on angular momentum and particle number: Application to 24Mg

    International Nuclear Information System (INIS)

    Valor, A.; Heenen, P.-H.; Bonche, P.

    2000-01-01

    We present in this paper the general framework of a method which permits to restore the rotational and particle number symmetries of wave functions obtained in Skyrme HF + BCS calculations. This restoration is nothing but a projection of mean-field intrinsic wave functions onto good particle number and good angular momentum. The method allows us also to mix projected wave functions. Such a configuration mixing is discussed for sets of HF + BCS intrinsic states generated in constrained calculations with suitable collective variables. This procedure gives collective states which are eigenstates of the particle number and the angular momentum operators and between which transition probabilities are calculated. An application to 24 Mg is presented, with mean-field wave functions generated by axial quadrupole constraints. Theoretical spectra and transition probabilities are compared to the experiment

  14. 99mTc labelled peptides for imaging of peripheral receptors

    International Nuclear Information System (INIS)

    Mustanser, J.; Anjum, A.

    2001-01-01

    Several peptides are being used as radiopharmaceuticals for receptor imaging scintigraphy. The peptide receptors are found in the tumours of various sites in the human body. Somatostatin is one of those, which is expressed by a variety of tumours say in brain cortex, medullary carcinoma of thyroid, adrenal glands, pancreas and gut. Therefore neuropeptides based on somatostatin analogues are labelled with different radionuclide, 123 I and 111 In. Efforts are underway to label RC-160 (an analogue of somatostatin) with 99m Tc because of its favourable radiation dosimetry, short half-life, low price, high count rate and better diagnostic efficacy. In this project various methods of labelling RC-160 with different radionuclides 125 I and 99m Tc have been studied in detail. Radioiodination of RC-160 was tried with 125 I using the iodogen method as directed and then with Chloramine T method. Labelling of RC-160 peptide with 99m Tc was done using two different aspects. Direct labelling with 99m Tc and indirect labelling with 99m Tc using double chelating agents. Radiochemical quality control was carried out applying instant thin layer chromatography using ITLC-SG strips in 85% of methanol. Later the HPLC analysis was used for its evaluation. To label RC-160 with 99m Tc the approach of direct labelling was attempted first. 46% labelling could be achieved with 95% of radiochemical purity. The biodistribution of 99m Tc-RC-160 complex in rats has also been studied to determine uptake in various sites of somatostatin receptors. Eventually, attempt was made to synthesize biomolecule by conjugating Boc protected RC-160 with benzoyl MAG-3. As a result 80% of Boc-RC-160 went under conjugation with benzoyl MAG-3. (author)

  15. Generator of 99m Tc with MnO2 as support of 99 Mo

    International Nuclear Information System (INIS)

    Granados C, F.; Serrano G, J.

    2002-01-01

    The generator of 99m Tc with MnO 2 as support of 99 Mo was studied. By mean of static experiments the retention of 99 Mo in MnO 2 in function of the stirring time and of the p H value of the solution of 99 Mo. It was found that the 99 Mo presents 100% of retention in MnO 2 in the rank of p H 3-11 and the balance was reached before of 10 minutes. In dynamic conditions the retention of 99 Mo in MnO 2 at p H=5 was also higher: 99.72%. The generated 99m Tc can be separated from 99 Mo, adsorbed in MnO 2 packed in the column, using distilled water at p H=5 or NaCl solution at 0.9%. With saline solution the elution yields were greater than 80% and only an aliquot of 5 ml was necessary for obtaining this yield. The better results were obtained when the column was packed with 1 g of MnO 2 . The water and the saline solution were passed through of the column with a flux of 1.25 ml/min. (Author)

  16. JENDL dosimetry file 99 (JENDL/D-99)

    International Nuclear Information System (INIS)

    Kobayashi, Katsuhei; Iwasaki, Shin

    2002-01-01

    The JENDL Dosimetry File 99 (JENDL/D-99), which is a revised version of the JENDL Dosimetry File 91 (JENDL/D-91), has been compiled and released for the determination of neutron flux and energy spectra. This work was undertaken to remove the inconsistency between the cross sections and their covariances in JENDL/D-91 since the covariances were mainly taken from IRDF-85 although the cross sections were based on JENDL-3. Dosimetry cross sections have been evaluated for 67 reactions on 47 nuclides together with covariances. The cross sections for 34 major reactions and their covariances were simultaneously generated, and the remaining 33 reaction data were mainly taken from JENDL/D-91. Latest measurements were taken into account in the evaluation. The resultant evaluated data are given in the neutron energy region below 20 MeV in both of point-wise and group-wise files in the ENDF-6 format. In order to confirm the reliability of the evaluated data, several integral tests have been carried out: comparisons with average cross sections measured in fission neutron fields, fast/thermal reactor spectra, DT neutron fields and Li(d,n) neutron fields. It was found from the comparisons that the cross sections calculated from JENDL/D-99 are generally in good agreement with the measured data. The contents of JENDL/D-99 and the results of the integral tests are described in this report. All of the dosimetry cross sections are shown in a graphical form in the Appendix. (author)

  17. Status of {sup 99}Mo-{sup 99m}Tc production development by (n, {gamma}) reaction

    Energy Technology Data Exchange (ETDEWEB)

    Tsuchiya, Kunihiko; Kaminaga, Masanori; Ishihara, Masahiro; Kawamura, Hiroshi [Japan Atomic Energy Agency, Oarai Research and Development Center, Oarai, Ibaraki (Japan); Mutalib, Abdul [National Nuclear Energy Agency of Indonesia (BATAN), Tangerang (Indonesia); Chakrov, Petr [Institute of Nuclear Physics, National Nuclear Center of Republic of Kazakhstan (INP-NNC-RK), Almaty (Kazakhstan)

    2012-03-15

    Technetium-99m ({sup 99m}Tc) is one of the most commonly used radioisotopes in the field of nuclear medicine. As one of effective uses of the JMTR, JAEA has a plan to produce {sup 99}Mo by (n, {gamma}) method, a parent nuclide of {sup 99m}Tc. JAEA has performed R and D on production method of {sup 99}Mo-{sup 99m}Tc in JMTR cooperating with foreign organizations and relevant Japanese enterprises under the cooperation programs. In this paper, present status of R and D for production of {sup 99}Mo-{sup 99m}Tc in JMTR under international cooperation is introduced and constructions of the irradiation and PIE facilities at the JMTR site are also described. (author)

  18. 99mTc-EDTA and 99mTc-DTPA complexes as hydrological tracers

    International Nuclear Information System (INIS)

    Dominguez, J.; Borroto, J.; Nazco, J.; Perez, E.; Gamboa, R.; Cruz, J.

    2002-01-01

    The [ 99m Tc-DTPA] 2- and [ 99m Tc-EDTA] 1- were evaluated as radiotracers for short time hydrological studies. Their complex stability after labelling with 9.25 GBq of 99m Tc, the behaviour against pH variations, from 5 to 9, in simulated solutions and in natural river waters and the sorption of these compounds on the river sediments, were tested in laboratory experiments. Finally field double tracing experiments were carried out for each of labelling complexes and Rhodamine WT. From recovery calculations not losses of the 99m Tc activity were observed. The shape of the RTD curves of the [ 99m Tc-DTPA] 2- and [ 99m Tc-EDTA] 1 were quite similar to the Rhodamine Wt ones. May be concluded that both complexes behaved conservatively on the studied environmental conditions. (author)

  19. Optimization of the 99m Tc generator with hydrotalcite as support of 99 Mo

    International Nuclear Information System (INIS)

    Aranda O, N.

    2004-01-01

    In the last years, in the laboratories of the National Institute of Nuclear Investigations (ININ) its have been investigating to the hydrotalcite like a material of support of the 99 Mo with the purpose of developing a new technetium generator. During the development of the investigations it has been demonstrated that when putting in contact to the HTC with an aqueous solution that contains anions of any type, the HTC re hydrate and the structure is regenerated to laminate of the hydrotalcite. If the present anions in the solution are molybdate anions (MoO 4 2- ), these anions passed to be part of the structure of the hydrotalcite (HT-MoO 4 ). These anions can contain, in turn, 99 Mo in their composition ( 99 MoO 4 2- ) and equally they can pass to be part of the structure of the hydrotalcite forming the HT- 99 MoO 4 . When the HT- 99 MoO 4 is packed in a column, the 99m Tc that it takes place when decaying the 99 Mo radioactively can separate the column using aqueous solution of NaCl. This way, in previous studies (Serrano, 2000) it was found that the aqueous solution of NaCl to 0.5% it is the but appropriate for elutriate at the 99m Tc from the column the yield of the elution of the 99m Tc was since high (98%) in the first elution, and the radionuclide contamination caused by the presence of 99 Mo in the eluate it was low ( 4 2- for gram of HTC). These facts, standing out the high capacity of the HTC to retain molybdate ions, they drove from a direct way to investigate the optimization of the generator of 99m Tc, with hydrotalcite like support of the 99 Mo, using 99 Mo of low specific activity. This finishes radioactive material it can be obtained by the irradiation of the 98 Mo (in the chemical form of MoO 3 or (NH 4 ) 2 MoO 4 ), with a flow of thermal neutrons in the nuclear reactor TRIGA Mark lll that one has in the Nuclear Center N abor Carrillo Flores . The technetium generators with alumina like support of the 99 Mo use 99 Mo of high specific activity

  20. Evaluation of 99Mo/99mTc generator experiment using PZC material and irradiated natural molybdenum

    International Nuclear Information System (INIS)

    Khongpetch, P.; Chingjit, S.; Dangprasert, M.; Rangsawai, W.; Virawat, N.

    2006-01-01

    Technetium-99m ( 99m Tc) is the most widely used radioisotope in nuclear medicine, accounting for more than 80% of all diagnostic nuclear medicine procedure. 99m Tc is almost exclusively produced from the decay of its parent molybdenum-99 ( 99 Mo). The present sources of 99 Mo are research reactors by using the (n, γ) nuclear reaction with natural molybdenum, resulting in inexpensive but low specific activity 99 Mo, or by neutron-induced fission of uranium-235, which result in expensive but high specific activity 99 Mo. The technology requirement for processing of 99 Mo from the (n, γ) 'activation method' is rather simple, and is within the reach of most developing countries operating research reactors. In the fission method' the technological and infrastructure requirements are some complex, and possibly can be sustained only by countries with advanced nuclear technology. To overcome these difficulties, Japan Atomic Energy Research Institute (JAERI) and KAKEN company have developed alternative technology for 99 Mo/ 99m Tc generator by using a molybdenum absorbent called Poly Zirconium compound (PZC) and irradiated natural molybdenum. The paper describes experiments for evaluation the performance of PZC as a column packing material for 99 Mo/ 99m Tc generator from (n, γ) 99 Mo. (author)

  1. Establishment of H2Mab-119, an Anti-Human Epidermal Growth Factor Receptor 2 Monoclonal Antibody, Against Pancreatic Cancer.

    Science.gov (United States)

    Yamada, Shinji; Itai, Shunsuke; Nakamura, Takuro; Chang, Yao-Wen; Harada, Hiroyuki; Suzuki, Hiroyoshi; Kaneko, Mika K; Kato, Yukinari

    2017-12-01

    Human epidermal growth factor receptor 2 (HER2) is overexpressed in breast cancer and is associated with poor clinical outcomes. In addition, HER2 expression has been reported in other cancers, such as gastric, colorectal, lung, and pancreatic cancers. An anti-HER2 humanized antibody, trastuzumab, leads to significant survival benefits in patients with HER2-overexpressing breast cancers and gastric cancers. Herein, we established a novel anti-HER2 monoclonal antibody (mAb), H 2 Mab-119 (IgG 1 , kappa), and characterized its efficacy against pancreatic cancers using flow cytometry, Western blot, and immunohistochemical analyses. H 2 Mab-119 reacted with pancreatic cancer cell lines, such as KLM-1, Capan-2, and MIA PaCa-2, but did not react with PANC-1 in flow cytometry analysis. Western blot analysis also revealed a moderate signal for KLM-1 and a weak signal for MIA PaCa-2, although H 2 Mab-119 reacted strongly with LN229/HER2 cells. Finally, immunohistochemical analyses with H 2 Mab-119 revealed sensitive and specific reactions against breast and colon cancers but did not react with pancreatic cancers, indicating that H 2 Mab-119 is useful for detecting HER2 overexpression in pancreatic cancers using flow cytometry and Western blot analyses.

  2. Studies on molybdenum elution study in dowex 1x8 resin applied on purification process of fission 99Mo

    International Nuclear Information System (INIS)

    Damasceno, M.O.; Yamaura, M.; Santos, J.L. dos; Forbicini, C.A.L.G. de O.

    2013-01-01

    Molybdenum-99 is the most widely employed radioisotope in nuclear medicine, due to its decay product, Technetium-99, which is used in radio-pharmaceutical marking molecules for diagnostic examinations tumor dis-eases. Today Brazil imports 99 Mo from some countries, so the National Commission of Nuclear Energy (CNEN) is implementing a new research reactor RMB, currently in the conceptual design phase. The process of separation of fission 99 Mo begins with the dissolution of uranium targets after irradiation in reactor; the resulting solution goes through a series of chromatographic columns that allows a gradual decontamination of other components, yielding the 99 Mo with high radio-chemical and chemical purity for use in nuclear medicine as a generator of 99 mTc. This work is part of the RMB research project to separate and purify the fission 99 Mo by chromatographic columns from alkaline dissolution of LEU UAl x -Al targets. In the present study Mo removal by batch assays and glass column was investigated using anionic exchanger Dowex 1x8. Different salts and its concentration, cations and temperature were evaluated on elution of molybdenum and iodine (contaminant) retained on resin Dowex 1x8, aiming at their use in the process of separation and purification in chromatography columns on Brazilian project. Results showed high recovery of Mo and low-level contamination by iodine using NaHCO 3 hot solution. (author)

  3. Determination of Tc-99 in radioactive wastes; Determinacion de Tc-99 en desechos radiactivos

    Energy Technology Data Exchange (ETDEWEB)

    Rivera S, A. A.

    2015-07-01

    Tc-99 is a fission product and one of the most important radionuclides from the view point of safety assessment for the disposal of radioactive waste because of its long half-life (2.1 x 10{sup 5} years) and high mobility in soil-water systems, if this is released into the environment in significant quantities can concentrate on plants and animals. Tc-99 is a pure beta emitter with a maximum energy of 292 KeV, so their quantification imposes destructive methods to be analyzed by liquid scintillation. Therefore the quantification of Tc-99 in ion exchange resins requires of the mineralization of these and separation of Tc-99 of other radioisotopes present in the resin. Therefore the object of this thesis is to develop a quantification method of Tc-99 content in spent exchange resins. So in order to track the behavior of technetium during digestion exchange resins and radiochemical separation, given its high volatility, in this work the {sup 99m}Tc is used. To determine the degree of mineralization of the resins, an analysis was performed by chromatography. Subsequently the method used to determine the percentage of {sup 99m}Tc aerosolized during mineralization of resin is described. After the method for the radiochemical separation of {sup 99m}Tc is presented by liquid-liquid extraction using crown ether as extractant; for this testing was performed by varying the molarity of the extractant, the ratio of solvent extractant, type of digestion of the resin and the presence of Sr-85, in order to study the behavior of {sup 99m}Tc in the presence of this radioisotope. Finally, a track beta spectra of a sample of {sup 99m}Tc eluted from a generator {sup 99}Mo/{sup 99m}Tc function of time was performed. (Author)

  4. Tc-99m erythromycin lactobionate inhalation scintigraphy in parenchymal lung diseases

    Energy Technology Data Exchange (ETDEWEB)

    Durak, Hatice E-mail: hdurak@kordon.deu.edu.tr; Aktogu, Serir; Degirmenci, Berna; Sayit, Elvan; Ertay, Tuerkan; Dereli, Sevket

    1999-08-01

    We have investigated Technetium 99m erythromycin lactobionate (Tc 99m EL) clearance from the lungs after inhalation, in the presence of an alveolitis. Eighteen patients (6 sarcoidosis, 7 idiopathic fibrosis, and 5 miliary tuberculosis) were imaged after the patients inhaled 1,110 MBq of Tc 99m EL. Clearance half time for the first 45 min, for 24 h, and retention at 24 h correlated with percentage of lymphocytes in bronchoalveolar lavage fluid (BAL) (r=.729, r=.883, and r=.826, respectively). There was a positive correlation between peripheral penetration (PP) and forced expiratory volume in 1 s (FEV{sub 1}) (r=.806) and forced vital capacity (FVC) (r=.781). Retention was more marked in sarcoidosis compared with tuberculosis (0.02599m EL may be related to number of BAL cells or presence of a lymphocytic alveolitis. Long residency time of Tc 99m EL in the lungs implies that erythromycin can also be administered by inhalation for therapeutic purposes.

  5. Technetium-99 levels in pertechnetate solutions from (n,γ) and (n,f) molybdenum-99 generators

    International Nuclear Information System (INIS)

    Moore, P.W.

    1983-04-01

    There is increasing evidence that, in some radiopharmaceutical kits, Tc-99 has an adverse effect on the imaging and labelling performance of Tc-99m. For example, labelling efficiency with red blood cells can be affected when 99/99m ratios exceed about 4:1. The 99/99m ratio in a target is about 13.5:1 after a seven-day irradiation in a nuclear reactor. The ratio increases slightly during the time needed for processing. With the chromatographic generators used in hospitals, up to 90 hours may elapse between the final wash stage of manufacture and the first elution, during which time, 99/99m ratios can increase to about 90:1. If elution efficiencies are high and the time between elutions is between 12 and 24 hours, ratios in the generator, hence in the eluates, may actually increase with each elution. In the case of ready-to-inject pertechnetate solutions, the critical time at which 99/99m ratios increase rapidly is the time between elution and use. If production conditions are poor, ratios may increase to more than 600:1 by the time of use. With better conditions and production schedules Tc-99 levels at the time of use are comparable to those from chromatographic generators

  6. The Usefulness of 99mTc-Sestamibi Scan in Preoperative Localization in Primary Hyperparathyroidism

    International Nuclear Information System (INIS)

    Baik, S. H.; Kim, S. M.; Choi, K. M.; Choi, Y. S.; Kim, S. J.; Yu, J. M.; Choi, D. S.; Choe, J. C.

    1995-01-01

    An accurate preoperative localization in patients with primary hyperparathyroidism is important for successful surgical intervention. There are many methods for the localization of the primary hyperparathyroidism such as ultrasonography, computerized tomography(CT), magnetic resonance imaging(MRI), angiography and 201 T1/ 99m Tc-subtraction scan. Among them 201T1/99mTc subtraction scan in known as the most accurate tool for preoperative localization. Recently 201 T1/ 99m Tc-Sestamibi has been used for parathyroid gland imaging. We experienced 19 primary hyperparathyroidisms accurately localized with 201 T1/ 99m Tcsubtraction imaging and 99m Tc-Sestamibi. The sensitivities of the 99m Tc-Sestamibi, 201T1/99mTc subtraction imaging, CT and US were 100%(5/5), 89.5%(17/19) and 61.7(12/19) respectively. With the combination of 99m Tc-Sestamibi and 201 T1/ 99T c-subtraction imaging we could localize with 100% accuracy. Although the case number is small, this study suggests that the 99m Tc-Sestamibi parathyroid scan is very useful and easy to use for preoperative localization in primary hyperparathyroidism.

  7. Study of different absorbent materials for the preparation of generator systems of {sup 99}Mo - {sup 99m}Tc and {sup 188}W-{sup 188}Re

    Energy Technology Data Exchange (ETDEWEB)

    Lopes, Paula Regina Corain; Osso Junior, Joao Alberto, E-mail: paulinhacorain@usp.b, E-mail: jaosso@ipen.b [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil)

    2009-07-01

    Amongst some currently radioisotopes, {sup 99m}Tc and {sup 188}Re present adequate decay properties for use in Nuclear Medicine. In the current times the most diagnosis examinations are performed with {sup 99m}Tc and {sup 188}Re is one radioisotope of potential use in therapy techniques. The objective of this work consists of determining the capacity of some adsorbent materials for retention of molybdenum and tungsten, aiming the optimization of generator systems of {sup 99}Mo-{sup 99m}Tc and {sup 188}W-{sup 188}Re with suitable characteristics for application in Nuclear Medicine. Known amounts, in mass, of molybdenum and tungsten were percolated through different chromatographic columns containing different commercial adsorbent materials such as: PZC (poly-zirconium compound), acid alumina and calcinated alumina used in the routine preparation of {sup 99}Mo-{sup 99m}Tc generators at IPEN. The tungsten ({sup 188}W), as well the PZC used in this project, supplied by Russia and Japan, respectively, through the International Atomic Energy Agency (IAEA) and used without any previous preparation. Also trace amounts of {sup 99}Mo and {sup 188}W were added to the initial solutions and the generators were assembled. The {sup 99}Mo-{sup 99m}Tc generators were then eluted with known volumes of 0.9% NaCl solution every 24 hours whereas the {sup 188}W-{sup 188}Re generators were eluted every 48 hours. The eluted samples were analyzed by Gamma Spectroscopy and later submitted to quality control evaluation. The results showed that the PZC presents superior retention capacity for Mo of 97.50mg Mo/gPZC, higher than in acid and calcinated alumina, however the elution efficiency at lower pHs is not so high. With regards to the experiments carried out with {sup 188}W and alumina, it was verified that the elution efficiency of {sup 188}Re was not reproducible and the retention capacity of W was 90.23mgW/gAl{sub 2}O{sub 3} at pH 7. (author)

  8. Scintigraphic findings on 99mTc-MDP, 99mTc-sestamibi and 99mTc-HMPAO images in Gaucher's disease

    International Nuclear Information System (INIS)

    Mariani, G.; Molea, N.; La Civita, L.; Porciello, G.; Lazzeri, E.; Ferri, C.

    1996-01-01

    We report here on the use of the lipophilic cationic complex technetium-99m sestamibi ( 99m Tc-MIBI), employed as an indicator of increased cellular density and metabolic activity, to evaluate Gaucher cell infiltrates in the bone marrow; 99m Tc-hexametazime ( 99m Tc-HMPAO) was also employed, as a pure indicator of lipidic infiltration in the bone marrow. A 67-year-old patient with known type 1 Gaucher's disease presented with a painful left hip and knee and difficulty in gait subsequent to traumatic fracture of the left femoral neck that had required implant of a fixation screw-plaque. Bone scan with 99m Tc-methylene diphosphonate revealed reduced uptake at the distal metaphyseal-epiphyseal femoral region. In addition, whole-body maps and spot-view acquisitions of the thighs and legs were recorded at both 30 min and 2.5 h after the injection of 99m Tc-MIBI: the scintigraphic pattern clearly showed increased uptake at several sites involved by Gaucher deposits in the bone marrow (both knees, with variable intensity in different areas), matching the bone changes detected by conventional x-ray. The target to non-target ratios slowly decreased with time, from an average value of 2.25 in the early scan to an average value of 2 in the delayed scan. The lipid-soluble agent 99m Tc-HMPAO exhibited a superimposable scintigraphic pattern of accumulation at the involved sites, though with lower target to non-target ratios (1.27-1.48). The results obtained in this patient suggest a potential role of 99m Tc-MIBI in the scintigraphic evaluation of Gaucher's lipid deposits in the bone marrow. If the results are confirmed in other patients, this radiopharmaceutical would offer clear advantages over 133 Xe because of its wider availability and greater practicality (i.v. administration of 99m Tc-MIBI versus inhalation of 133 Xe, and use of a single gamma camera instead of two as with 133 Xe). (orig.). With 3 figs

  9. Structural Insights into TMB-1 and the Role of Residues 119 and 228 in Substrate and Inhibitor Binding.

    Science.gov (United States)

    Skagseth, Susann; Christopeit, Tony; Akhter, Sundus; Bayer, Annette; Samuelsen, Ørjan; Leiros, Hanna-Kirsti S

    2017-08-01

    Metallo-β-lactamases (MBLs) threaten the effectiveness of β-lactam antibiotics, including carbapenems, and are a concern for global public health. β-Lactam/β-lactamase inhibitor combinations active against class A and class D carbapenemases are used, but no clinically useful MBL inhibitor is currently available. Tripoli metallo-β-lactamase-1 (TMB-1) and TMB-2 are members of MBL subclass B1a, where TMB-2 is an S228P variant of TMB-1. The role of S228P was studied by comparisons of TMB-1 and TMB-2, and E119 was investigated through the construction of site-directed mutants of TMB-1, E119Q, E119S, and E119A (E119Q/S/A). All TMB variants were characterized through enzyme kinetic studies. Thermostability and crystallization analyses of TMB-1 were performed. Thiol-based inhibitors were investigated by determining the 50% inhibitory concentrations (IC 50 ) and binding using surface plasmon resonance (SPR) for analysis of TMB-1. Thermostability measurements found TMB-1 to be stabilized by high NaCl concentrations. Steady-state enzyme kinetics analyses found substitutions of E119, in particular, substitutions associated with the penicillins, to affect hydrolysis to some extent. TMB-2 with S228P showed slightly reduced catalytic efficiency compared to TMB-1. The IC 50 levels of the new thiol-based inhibitors were 0.66 μM (inhibitor 2a) and 0.62 μM (inhibitor 2b), and the equilibrium dissociation constant ( K D ) of inhibitor 2a was 1.6 μM; thus, both were more potent inhibitors than l-captopril (IC 50 = 47 μM; K D = 25 μM). The crystal structure of TMB-1 was resolved to 1.75 Å. Modeling of inhibitor 2b in the TMB-1 active site suggested that the presence of the W64 residue results in T-shaped π-π stacking and R224 cation-π interactions with the phenyl ring of the inhibitor. In sum, the results suggest that residues 119 and 228 affect the catalytic efficiency of TMB-1 and that inhibitors 2a and 2b are more potent inhibitors for TMB-1 than l-captopril. Copyright

  10. RESUME 99. Rapid environmental surveying using mobile equipment

    Energy Technology Data Exchange (ETDEWEB)

    Karlsson, S; Mellander, H; Lindgren, J; Finck, R [Swedish Radiation Protection Inst.(Sweden); Lauritzen, B [Risoe National Lab., (Denmark)

    2000-08-01

    This report describes the exercise RESUME 99 that took place in the surroundings of Gaevle in Sweden, September 6-9, 1999. The exercise was a part of the project BOK-1.2, Mobile measurements and measurement strategies, within the NKS research program for 1998-2001. RESUME 99 was primarily aimed at testing mobile gamma spectrometry with systems carried by cars, but also in situ measurements were carried out during the exercise. In the exercise, the activity levels of {sup 137} Cs stemming from Chernobyl accident in 1986 was measured and mapped. The objectives of the exercise were to train participating teams in measuring, to test co-operation for nuclear emergency preparedness, and to prepare for a larger European exercise in 2001. Another objective of the exercise was to integrate the carborne gamma-ray survey with recent airborne gamma-ray survey measurements of the area. The exercise generated a substantial database that can be used for further research in this field. Several interesting features were included in the RESUME 99 exercise, such as advanced on-site processing of data and direct presentation of results on an exercise web site. This report describes the planning, preparation and execution of the exercise, the participating teams, and results that was presented during the exercise. (au)

  11. RESUME 99. Rapid environmental surveying using mobile equipment

    International Nuclear Information System (INIS)

    Karlsson, S.; Mellander, H.; Lindgren, J.; Finck, R.; Lauritzen, B.

    2000-08-01

    This report describes the exercise RESUME 99 that took place in the surroundings of Gaevle in Sweden, September 6-9, 1999. The exercise was a part of the project BOK-1.2, Mobile measurements and measurement strategies, within the NKS research program for 1998-2001. RESUME 99 was primarily aimed at testing mobile gamma spectrometry with systems carried by cars, but also in situ measurements were carried out during the exercise. In the exercise, the activity levels of 137 Cs stemming from Chernobyl accident in 1986 was measured and mapped. The objectives of the exercise were to train participating teams in measuring, to test co-operation for nuclear emergency preparedness, and to prepare for a larger European exercise in 2001. Another objective of the exercise was to integrate the carborne gamma-ray survey with recent airborne gamma-ray survey measurements of the area. The exercise generated a substantial database that can be used for further research in this field. Several interesting features were included in the RESUME 99 exercise, such as advanced on-site processing of data and direct presentation of results on an exercise web site. This report describes the planning, preparation and execution of the exercise, the participating teams, and results that was presented during the exercise. (au)

  12. Verification of dosimetric commissioning accuracy of intensity modulated radiation therapy and volumetric modulated arc therapy delivery using task Group-119 guidelines

    Directory of Open Access Journals (Sweden)

    Karunakaran Kaviarasu

    2017-01-01

    Full Text Available Aim: The purpose of this study is to verify the accuracy of the commissioning of intensity-modulated radiation therapy (IMRT and volumetric-modulated arc therapy (VMAT based on the recommendation of the American Association of Physicists in Medicine Task Group 119 (TG-119. Materials and Methods: TG-119 proposes a set of clinical test cases to verify the accuracy of IMRT planning and delivery system. For these test cases, we generated two sets of treatment plans, the first plan using 7–9 IMRT fields and a second plan utilizing two-arc VMAT technique for both 6 MV and 15 MV photon beams. The template plans of TG-119 were optimized and calculated by Varian Eclipse Treatment Planning System (version 13.5. Dose prescription and planning objectives were set according to the TG-119 goals. The point dose (mean dose to the contoured chamber volume at the specified positions/locations was measured using compact (CC-13 ion chamber. The composite planar dose was measured with IMatriXX Evaluation 2D array with OmniPro IMRT Software (version 1.7b. The per-field relative gamma was measured using electronic portal imaging device in a way similar to the routine pretreatment patient-specific quality assurance. Results: Our planning results are compared with the TG-119 data. Point dose and fluence comparison data where within the acceptable confident limit. Conclusion: From the obtained data in this study, we conclude that the commissioning of IMRT and VMAT delivery were found within the limits of TG-119.

  13. GPR119 - a major Enteroendocrine Sensor of Dietary Triglyceride Metabolites Co-acting in Synergy with FFA1 (GPR40)

    DEFF Research Database (Denmark)

    Ekberg, Jeppe H; Pedersen, Maria Hauge; Kristensen, Line V

    2016-01-01

    the FFA1 agonist was administered on top of appropriately low doses of the GPR119 agonist a clear synergistic, i.e. more than additive effect was observed. It is concluded that the 2-MAG receptor GPR119 is at least as important as the LCFA receptor FFA1 in mediating the triglyceride-induced secretion......Triglycerides are among the most efficacious stimulators of incretin secretion; however the relative importance of FFA1 (GPR40), FFA4 (GPR120) and GPR119 which all recognize triglyceride metabolites, i.e. LCFA and 2-MAG respectively, is still unclear. Here, we find all three receptors to be highly...... the synthetic FFA1 agonists, TAK-875 stimulated GLP-1 secretion to a similar extent as the prototype GLP-1 secretagogue neuromedin C, this however only corresponded to approx. half the maximal efficiency of the GPR119 agonist AR231453 whereas the GPR120 agonist Metabolix-209 had no effect. Importantly, when...

  14. Localization diagnosis of hyperfunctional parathyroid gland using 99Tcm-MIBI and 99TcmO4- imaging

    International Nuclear Information System (INIS)

    Zhang Fenru; Deng Huixing; Duan Xiaoyi; Xue Jianjun; Gao Rui

    2010-01-01

    Objective: To study the localization diagnosis value of nuclide imaging by 99 Tc m -MIBI double phase parathyroid combined with 99 Tc m O 4 - thyroid imaging in patients with hyperparathyroidism (HPT). Methods: Patients with primary HPT were 36 cases. Control groups were 10 cases with thyroid disease. Early phase imaging was performed in 15 minute after injecting imaging agent 99 Tc m -MIBI. Delay phase imaging was performed in 2 hours. 36 HPT patients and 10 cases control groups were also performed 99 Tc m O 4 - thyroid imaging 24 hours later. The two kinds of imaging were compared with each other, were analyzed, and were underwent imaging subtracted by eyes and imaging results judgment. Results: In 36 cases of HPT patients, 34 cases showed positive result imaging with 99 Tc m -MIBI/ 99 Tc m O 4 - imaging. 2 cases showed false negative result. Positive rate was 94.44 % with 99 Tc m -MIBI/ 99 Tc m O 4 - imaging. The positive result imaging showed abnormal increased uptake of 99 Tc m -MIBI. In 36 cases of HPT patients, 12 cases showed positive result with single 99 Tc m -MIBI imaging. 4 cases showed false negative imaging. 20 cases showed ambiguous positive results. Positive rate was 88.89% (55.56% was ambiguous positive results) with single 99 Tc m -MIBI imaging. In 10 cases control groups, 3 cases showed false positive results with single 99 Tc m -MIBI imaging. 1 case showed ambiguous false positive results. No case showed false positive result with 99 Tc m -MIBI/ 99 Tc m O 4 - imaging. Conclusion: 99 Tc m -MIBI parathyroid double phase imaging combined with 99 Tc m O 4 - thyroid imaging have important value for diagnoses and localization of hyperparathyroidism. 99 Tc m -MIBI/ 99 Tc m O 4 - imaging have higher positive rate and higher specificity than single 99 Tc m -MIBI imaging for diagnoses and localization of hyperfunction parathyroid gland. (authors)

  15. D-fructose-binding proteins in bull seminal plasma: Isolation and characterization

    Czech Academy of Sciences Publication Activity Database

    Liberda, J.; Kraus, Marek; Ryšlavá, H.; Vlasáková, M.; Jonáková, Věra; Tichá, M.

    2001-01-01

    Roč. 47, č. 4 (2001), s. 113-119 ISSN 0015-5500 R&D Projects: GA ČR GA303/99/0357; GA ČR GV524/96/K162 Institutional research plan: CEZ:AV0Z5052915 Keywords : bull seminal plasma * non-heparin-binding and heparin-binding proteins * D-fructose-binding proteins Subject RIV: EB - Genetics ; Molecular Biology Impact factor: 0.519, year: 2001

  16. Overexpression of PtrMYB119, a R2R3-MYB transcription factor from Populus trichocarpa, promotes anthocyanin production in hybrid poplar.

    Science.gov (United States)

    Cho, Jin-Seong; Nguyen, Van Phap; Jeon, Hyung-Woo; Kim, Min-Ha; Eom, Seok Hyun; Lim, You Jin; Kim, Won-Chan; Park, Eung-Jun; Choi, Young-Im; Ko, Jae-Heung

    2016-09-01

    Anthocyanins are a group of colorful and bioactive natural pigments with important physiological and ecological functions in plants. We found an MYB transcription factor (PtrMYB119) from Populus trichocarpa that positively regulates anthocyanin production when expressed under the control of the CaMV 35S promoter in transgenic Arabidopsis Amino acid sequence analysis revealed that PtrMYB119 is highly homologous to Arabidopsis PAP1 (PRODUCTION OF ANTHOCYANIN PIGMENT1), a well-known transcriptional activator of anthocyanin biosynthesis. Independently produced transgenic poplars overexpressing PtrMYB119 or PtrMYB120 (a paralogous gene to PtrMYB119) (i.e., 35S::PtrMYB119 and 35S::PtrMYB120, respectively) showed elevated accumulation of anthocyanins in the whole plants, including leaf, stem and even root tissues. Using a reverse-phase high-performance liquid chromatography, we confirmed that the majority of the accumulated anthocyanin in our transgenic poplar is cyanidin-3-O-glucoside. Gene expression analyses revealed that most of the genes involved in the anthocyanin biosynthetic pathway were highly upregulated in 35S::PtrMYB119 poplars compared with the nontransformed control poplar. Among these genes, expression of PtrCHS1 (Chalcone Synthase1) and PtrANS2 (Anthocyanin Synthase2), which catalyze the initial and last steps of anthocyanin biosynthesis, respectively, was upregulated by up to 350-fold. Subsequent transient activation assays confirmed that PtrMYB119 activated the transcription of both PtrCHS1 and PtrANS2 Interestingly, expression of MYB182, a repressor of both anthocyanin and proanthocyanidin (PA) biosynthesis, was largely suppressed in 35S::PtrMYB119 poplars, while expression of MYB134, an activator of PA biosynthesis, was not changed significantly. More interestingly, high-level accumulation of anthocyanins in 35S::PtrMYB119 poplars did not have an adverse effect on plant growth. Taken together, our results demonstrate that PtrMYB119 and PtrMYB120

  17. Optimization of the {sup 99m} Tc generator with hydrotalcite as support of {sup 99} Mo; Optimizacion del generador de {sup 99m} Tc con hidrotalcita como soporte del {sup 99} Mo

    Energy Technology Data Exchange (ETDEWEB)

    Aranda O, N

    2004-07-01

    In the last years, in the laboratories of the National Institute of Nuclear Investigations (ININ) its have been investigating to the hydrotalcite like a material of support of the {sup 99} Mo with the purpose of developing a new technetium generator. During the development of the investigations it has been demonstrated that when putting in contact to the HTC with an aqueous solution that contains anions of any type, the HTC re hydrate and the structure is regenerated to laminate of the hydrotalcite. If the present anions in the solution are molybdate anions (MoO{sub 4}{sup 2-}), these anions passed to be part of the structure of the hydrotalcite (HT-MoO{sub 4}). These anions can contain, in turn, {sup 99} Mo in their composition ({sup 99}MoO{sub 4}{sup 2-}) and equally they can pass to be part of the structure of the hydrotalcite forming the HT-{sup 99}MoO{sub 4}. When the HT-{sup 99}MoO{sub 4} is packed in a column, the {sup 99m}Tc that it takes place when decaying the {sup 99}Mo radioactively can separate the column using aqueous solution of NaCl. This way, in previous studies (Serrano, 2000) it was found that the aqueous solution of NaCl to 0.5% it is the but appropriate for elutriate at the {sup 99m}Tc from the column the yield of the elution of the {sup 99m}Tc was since high (98%) in the first elution, and the radionuclide contamination caused by the presence of {sup 99}Mo in the eluate it was low (<0.01%). In this investigation it was also found that the HTC has a high capacity to retain molybdate ions (255.1 mg of ions MoO{sub 4}{sup 2-} for gram of HTC). These facts, standing out the high capacity of the HTC to retain molybdate ions, they drove from a direct way to investigate the optimization of the generator of {sup 99m}Tc, with hydrotalcite like support of the {sup 99}Mo, using {sup 99}Mo of low specific activity. This finishes radioactive material it can be obtained by the irradiation of the {sup 98}Mo (in the chemical form of MoO{sub 3} or (NH{sub 4

  18. Evaluation of the absorbed dose to the kidneys due to Tc{sup 99m} (DTPA) / Tc{sup 99m} (Mag3) and Tc{sup 99m} (Dmsa); Evaluacion de la dosis absorbida en los rinones debido al Tc{sup 99m} (DTPA) / Tc{sup 99m} (MAG3) y Tc{sup 99m} (DMSA)

    Energy Technology Data Exchange (ETDEWEB)

    Vasquez A, M.; Murillo C, F.; Castillo D, C.; Rocha J, J.; Sifuentes D, Y.; Sanchez S, P. [Universidad Nacional de Trujillo, Av. Juan Pablo II s/n, Trujillo (Peru); Idrogo C, J.; Marquez P, F., E-mail: marvva@hotmail.com [Instituto Nacional de Enfermedades Neoplasicas, Av. Angamos 2520, Lima (Peru)

    2015-10-15

    The absorbed dose in the kidneys of adult patients has been assessed using the biokinetics of radiopharmaceuticals containing Tc{sup 99m} (DTPA) / Tc{sup 99m} (Mag3) or Tc{sup 99m} (Dmsa).The absorbed dose was calculated using the formalism MIRD and the Cristy-Eckerman representation for the kidneys. The absorbed dose to the kidneys due to Tc{sup 99m} (DTPA) / Tc{sup 99m} (Mag3), are given by 0.00466 mGy.MBq{sup -1} / 0.00339 mGy.MBq{sup -1}. Approximately 21.2% of the absorbed dose is due to the bladder (content) and the remaining tissue, included in biokinetics of Tc{sup 99m} (DTPA) / Tc{sup 99m} (Mag3). The absorbed dose to the kidneys due to Tc{sup 99m} (Dmsa) is 0.17881 mGy.MBq{sup -1}. Here, 1.7% of the absorbed dose is due to the bladder, spleen, liver and the remaining tissue, included in biokinetics of Tc{sup 99m} (Dmsa). (Author)

  19. Hepatic accumulation of sup(99m)Tc-Sn-diphosphonate

    International Nuclear Information System (INIS)

    Hayashi, Sanshin; Oyama, Kazuyuki; Hirakawa, Ken; Akaike, Akira; Kogure, Takashi

    1977-01-01

    Six cases of hepatic accumulation of sup(99m)Tc-Sn-EHDP (ethane-1-hydroxy-1,1-diphosphonate) were encountered among 31 cases of bone scintigram. There were no uniformly common factors in sex, age, disease, liver function, or other laboratory data in these six patients. Colloidal formation was suspected since sup(99m)Tc-Sn-EHDP accumulated in the liver and spleen. EHDP vials from the same kit were analyzed and nothing abnormal was detected. EHDP vials of the same lot number were used in all of 31 cases. Samples of sup(99m)Tc eluate obtained from the same generator used to prepare EHDP and saline eluent from the same stock material used to elute the generator were analyzed. A small amount of aluminum ion and other oxidizer were found but they were thought to be insufficient as factors in the high liver uptake of EHDP because of too small a quantity. pH of sup(99m)Tc eluate was not unusual. Colloidal formation at the time of preparation of sup(99m)Tc-Sn-EHDP is not conceivable since most of the patients undergo bone scintigram without hepatic accumulation. It was assumed that somatic metallic ion substance, serum protein, or other endogeneous matter was responsible for the high liver uptake of EHDP. (auth.)

  20. Rechargeable sup(99)MO/sup(99m)TC generator system

    International Nuclear Information System (INIS)

    Thornton, A.K.; Cerone, F.E.

    1980-01-01

    A rechargeable radioisotope generator system is described in which the transfer of the parent isotope, molybdenum 99, can be affected safely and easily. Part of the system consists of a shielded shipping vial for the parent isotope. The generator consists of an alumina column upon which molybdenum 99 may be adsorbed and from which technetium 99m may be eluted. The generator is shipped as a cold package to the user and is charged as needed. A transfer mechanism is incorporated in the shipping shield, which allows the septum of the vial to be pierced and the contents to be transferred to the generator essentially automatically. (LL)

  1. Comparative analysis of 99mTc-depreotide and 99mTc-EDDA/HYNIC-TOC thorax scintigrams acquired for the purpose of differential diagnosis of solitary pulmonary nodules.

    Science.gov (United States)

    Płachcińska, Anna; Mikołajczak, Renata; Kozak, Józef; Rzeszutek, Katarzyna; Kuśmierek, Jacek

    2006-01-01

    Tc-EDDA/HYNIC-TOC scintigrams were true negative, 4--equivocal and 2 false positive. Moreover, 99mTc-depreotide additionally revealed mediastinal and hilar lesions in 9 patients with benign lesions and 99mTc-EDDA/HYNIC-TOC - in 8. A visual comparison of scintigrams revealed a higher quality of 99mTc-Depreotide images in comparison with 99mTc-EDDA/HYNIC-TOC ones. 99mTc-Depreotide showed a higher than 99mTc-EDDA/HYNIC-TOC accumulation in lung tumours compared with blood pool (heart) - 4.5 (s.d. 1.05) and 1.8 (s.d. 0.29), respectively (p EDDA/HYNIC-TOC scintigrams than on 99mTc-depreotide ones (16.4% vs. 11.4%; p < 0.01). Although both radiopharmaceuticals show similar diagnostic efficacy in differentiation of SPNs, a tendency toward a higher number of false positive results on 99mTc-depreotide scintigrams probably leads to a lower specificity. Better statistical quality of 99mTc-depreotide scintigrams facilitates their interpretation and a distinct outline of lungs simplify localization of lesions. A substantial number of false positive lesions in mediastinal and hilar regions in patients without a neoplastic process hamper the usefulness of both radiotracers for effective detection of lung cancer metastases to lymph nodes.

  2. Moessbauer spectroscopy of isotope separator implanted sup(119m)Sn in FCC metals

    International Nuclear Information System (INIS)

    Larsen, A.N.; Weyer, G.

    1979-01-01

    Radioactive sup(119m)Sn has been implanted in FCC metals by means of an isotope separator. Moessbauer spectra have been measured for the 24 keV transition of 119 Sn. Large substitutional fractions are found in all cases. A correlation for substitutional lattice sites between the measured isomer shifts of the impurity atoms and the force constants of the host lattices is discussed. Debye-Waller factors determined for substitutional Sn in the host lattices are found to be smaller than values calculated by a simple mass-defect model. For some host metals indications of an influence of radiation damage on the spectra are observed. Defect sites are assigned to Sn in aluminium and lead. Qualitative conclusions on the structures of these defects are drawn from the determined Moessbauer parameters. (author)

  3. Determinants of Attrition to Follow-Up in a Multicentre Cohort Study in Children-Results from the IDEFICS Study

    DEFF Research Database (Denmark)

    Hense, Sabrina; Pohlabeln, Hermann; Michels, Nathalie

    2013-01-01

    (OR = 1.46; 99% CI: 1.19, 1.79) was lacking. Drop-out proportion rose with the number of missing items. Overweight, low education, single parenthood and low well-being scores were independent determinants of attrition. Baseline participation, and the individual determinant effects seemed unrelated...... at 훼 = 0 . 0 1 to account for the large sample size. The strongest associations were seen for baseline item non-response, especially when information on migration background (odds ratio (OR) = 1.55; 99% confidence interval (CI): 1.04, 2.31), single parenthood (OR = 1.37; 99% CI: 1.12, 1.67), or well-being...

  4. The preparation and biodistribution of a new 99Tcm-nitrito complex 99TcmN-MIBI

    International Nuclear Information System (INIS)

    Zhang Xianzhong; Wang Xuebin; Zhang Junbo

    1997-01-01

    The technetium-99m nitrito intermediate is synthesized by using SnCl 2 ·2H 2 O as reductant, and the complex 99 Tc m N-MIBI is obtained through ligand exchange reaction. The labelling yield of 99 Tc m N-MIBI is over 95% by TLC. The conditions of preparing 99 Tc m N-MIBI are optimized. Results of stability and partition coefficient of 99 Tc m N-MIBI indicate that the complex is lipophilic and stable over 10 h at room temperature. The biodistribution of 99 Tc m N-MIBI in mice shows high myocardium uptake, and rather rapid clearance. For 5-min post-injection the heart-to-blood, heart-to-lung and heart-to-liver ratios are 3.18, 1.72 and 1.42, respectively. The new complex may be suitable for instant myocardial imaging. 99 Tc m N-MIBI has significant different biodistribution characteristics from 99 Tc m -MIBI. Based on these promising properties, 99 Tc m N-MIBI should be a new potential myocardial perfusion imaging agent

  5. The use of 99Mo/99mTc generators in the analysis of low levels of 99Tc in environmental samples by radiochemical methods

    International Nuclear Information System (INIS)

    Dowdall, M.; Selnaes, Oe.G.; Lind, B.; Gwynn, J.P.

    2010-01-01

    The analysis of low levels of 99 Tc in environmental samples presents special challenges, particularly with respect to the selection of an appropriate and practicable chemical yield tracer. Of all the tracers available, 99m Tc eluted from 99 Mo/ 99m Tc generators appears to be the most practicable in terms of availability, ease of use and cost. These factors have led to an increase in the use of such generators for the provision of 99m Tc as yield tracer for 99 Tc. For the analysis of low levels ( 3 or kg) of 99 Tc in environmental samples, consideration must be given to the radiochemical purity of the tracer solution with respect to contamination with both 99 Tc and other radionuclides. Due to the variable nature of the extent of the interference from tracer solution to tracer solution, it is unwise to try and establish a correction factor for any single generator. The only practical solution to the problem therefore is to run a 'blank' sample with each batch of samples drawn from a single tracer solution. (LN)

  6. 99mTc-diethyl-IDA chloescintigraphy

    International Nuclear Information System (INIS)

    Kim, J. W.; Oh, K. C.; Bae, B. H.; Kim, Y. S.; Park, B. H.

    1981-01-01

    For many years, 131 I-rose bengal has been used as the main hepatobiliary radiopharmaceutical. The undesirable physical characteristics of the radioiodine, however, finally prevented its widespread use in clinical medicine. In recent years, a number of hepatobiliary radiopharmaceuticals employing 99m Tc and 123 I as indicator have been introduced. 99m Tc-diethyl-IDA is a most promising one in these agents. Cholescintigraphy, using 99m Tc-diethyl-IDA was performed in 10 normal subjects and 32 patients suffering from various hepatobiliary disturbances, from Sep. -'79 to Aug-' 80, at the department of radiology, Maryknoll Hospital. The following results are obtained: 1. In normal fasting subjects, the liver, GB, CBD, and the proximal portion of small bowel are clearly delineated within 30 min after the injection. After a fatty meal, the radioactivity of the liver and CBD is notably disappeared with increase of the activity in GB and small bowel. 2. A dilatation of the main biliary ducts is a pathognomomic sign of partial mechanical obstructive disorders and a key point of D.Dx from hepatocellular disorders. 3. In cases of complete biliary obstruction, the radioactivity of the liver, CBD, and small bowel is not separated and the background activity is markedly increased. The kidneys are well visualized. 4. In severe hyperbilirubinaemia of above 10mg%, this method is not valuable

  7. Scintigraphic imaging with 99mTc- exorphin C in rabbits

    International Nuclear Information System (INIS)

    Ertay, T.; Uenak, P.; Tasci, C.; Zihnioglu, F.; Durak, H.

    2005-01-01

    Exorphin C is a peptide with five amino acids [(Tyr-Pro-Ile-Ser-Leu) Trifluoroacetate salt] (Sigma) that has an affinity to opioid receptor-expressing tissues and tumors. Exorphin-C was labeled with 99m Tc using glucoheptonate (GH) as bifunctional chelating agent. Then, we investigated its radiopharmaceutical potential as opioid receptor-expressing tissue on rabbits. Quality controls were performed by ITLC, paper electrophoresis and HPLC. Labeling efficiency was higher than 98%. The compound was stable for at least 5 h at room temperature. Scintigraphic imaging with 99m Tc-GH-exorphin C ( 99m Tc-GE) was performed on male Albino rabbits. Static images were obtained from anterior projection using a Camstar XR/T gamma camera at several time intervals. Although a significant amount of activity was seen in the brain, less activity was seen on receptor saturation studies at 30 min. Slight hepatobiliary excretion was seen, though the main excretion route was renal. After saturating, the receptor hepatobiliary excretion was not seen; the only excretion route was renal

  8. Diversification in the Supply Chain of (99)Mo Ensures a Future for (99m)Tc.

    Science.gov (United States)

    Cutler, Cathy S; Schwarz, Sally W

    2014-07-01

    The uncertain availability of (99m)Tc has become a concern for nuclear medicine departments across the globe. An issue for the United States is that currently it is dependent on a supply of (99m)Tc (from (99)Mo) that is derived solely by production outside the United States. Since the United States uses half the world's (99)Mo production, the U.S. (99)Mo supply chain would be greatly enhanced if a producer were located within the United States. The fragility of the old (99)Mo supply chain is being addressed as new facilities are constructed and new processes are developed to produce (99)Mo without highly enriched uranium. The conversion to low-enriched uranium is necessary to minimize the potential misuse of highly enriched uranium in the world for nonpeaceful means. New production facilities, new methods for the production of (99)Mo, and a new generator elution system for the supply of (99m)Tc are currently being pursued. The progress made in all these areas will be discussed, as they all highlight the need to embrace diversity to ensure that we have a robust and reliable supply of (99m)Tc in the future. © 2014 by the Society of Nuclear Medicine and Molecular Imaging, Inc.

  9. 99mTc gel generators based on zirconium molybdate-99Mo: III: Influence of preparatory conditions of zirconium molybdate-99Mo gel on generator performance

    International Nuclear Information System (INIS)

    Saraswathy, P.; Sarkar, S.K.; Arjun, G.; Ramamoorthy, N.; Nandy, S.K.

    2004-01-01

    The effect of subtle variations on zirconium molybdate- 99 Mo gel preparatory conditions, such as stoichiometry of reactants, pH of gel formation, conditioning of gel granules etc., prior to elution were investigated primarily to arrive at the conditions resulting in high 99m Tc release and minimal 99 Mo breakthrough upon elution with normal saline. Zirconium molybdate- 99 Mo gels were prepared by reacting solutions of Zr and Mo in mole ratios of 0.75-1.5. Both water and normal saline were used for gel disintegration, and the release of 99m Tc and 99 Mo from gel columns into eluates was compared. Sharper elution profile of 99m Tc, but with significantly higher 99 Mo breakthrough (5-8 times), was obtained when water alone was used for disintegration and elution, in comparison to when saline was used. Gels exhibiting optimum characteristics were found to be formed at a pH of 4-5 by reacting [Zr]: [Mo] in the mole ratio of 1.25: 1 and after drying, the product was dispersed into granules by disintegration with normal saline. 99m Tc elution efficiency was found to be ∝ 75% and 99 Mo breakthrough ∝ 0.05%. The elution profile was sharp when a 6 g gel column coupled to a 2 g acidic alumina column (to trap 99 Mo) was eluted with 6-9 ml normal saline. Generators containing upto 23 GBq 99 Mo were prepared, eluted extensively without changing the alumina column and found to provide pertechnetate of good quality, commensurate with hospital radiopharmacy requirements. (orig.)

  10. Siberian Chemical Combine laboratory project work plan, fiscal year 1999

    International Nuclear Information System (INIS)

    Morgado, R.E.; Acobyan, R.; Shropsire, R.

    1998-01-01

    The Siberian Chemical Combine (SKhK), Laboratory Project Work Plan (Plan) is intended to assist the US Laboratory Project Team, and Department of Energy (DOE) staff with the management of the FY99 joint material protection control and accounting program (MPC and A) for enhancing nuclear material safeguards within the Siberian Chemical Combine. The DOE/Russian/Newly Independent States, Nuclear Material Task Force, uses a project work plan document for higher-level program management. The SKhK Plan is a component of the Russian Defense related Sites' input to that document. In addition, it contains task descriptions and a Gantt Chart covering the FY99 time-period. This FY99 window is part of a comprehensive, Project Status Gantt Chart for tasking and goal setting that extends to the year 2003. Secondary and tertiary levels of detail are incorporated therein and are for the use of laboratory project management. The SKhK Plan is a working document, and additions and modifications will be incorporated as the MPC and A project for SKhK evolves

  11. 29 CFR 99.400 - Responsibilities.

    Science.gov (United States)

    2010-07-01

    ... 29 Labor 1 2010-07-01 2010-07-01 true Responsibilities. 99.400 Section 99.400 Labor Office of the... Pass-through Entities § 99.400 Responsibilities. (a) Cognizant agency for audit responsibilities... the report submission due date required by § 99.320(a). The cognizant agency for audit may grant...

  12. Cyclotron Production of Technetium-99m

    Science.gov (United States)

    Gagnon, Katherine M.

    Technetium-99m (99mTc) has emerged as the most widely used radionuclide in medicine and is currently obtained from a 99Mo/ 99mTc generator system. At present, there are only a handful of ageing reactors worldwide capable of producing large quantities of the parent isotope, 99Mo, and owing to the ever growing shutdown periods for maintenance and repair of these ageing reactors, the reliable supply 99mTc has been compromised in recent years. With an interest in alternative strategies for producing this key medical isotope, this thesis focuses on several technical challenges related to the direct cyclotron production of 99mTc via the 100Mo(p,2n)99mTc reaction. In addition to evaluating the 100Mo(p,2n)99mTc and 100Mo(p,x)99Mo reactions, this work presented the first experimental evaluation of the 100Mo(p,2n) 99gTc excitation function in the range of 8-18 MeV. Thick target calculations suggested that large quantities of cyclotron-produced 99mTc may be possible. For example, a 6 hr irradiation at 500 μA with an energy window of 18→10 MeV is expected to yield 1.15 TBq of 99mTc. The level of coproduced 99gTc contaminant was found to be on par with the current 99Mo/99mTc generator standard eluted with a 24 hr frequency. Highly enriched 100Mo was required as the target material for 99mTc production and a process for recycling of this expensive material is presented. An 87% recovery yield is reported, including metallic target preparation, irradiation, 99mTc extraction, molybdate isolation, and finally hydrogen reduction to the metal. Further improvements are expected with additional optimization experiments. A method for forming structurally stable metallic molybdenum targets has also been developed. These targets are capable of withstanding more than a kilowatt of beam power and the reliable production and extraction of Curie quantities of 99mTc has been demonstrated. With the end-goal of using the cyclotron-produced 99mTc clinically, the quality of the cyclotron

  13. STRUCTURE OF ECAP ALUMINIUM AFTER DIFFERENT NUMBER OF PASSES

    Directory of Open Access Journals (Sweden)

    Lucia Ilucová

    2011-05-01

    Full Text Available The structure of high purity (99.99% aluminium processed by equal channel angular pressing in the as pressed state after different number of passes was examined using various stereological methods. An extreme inhomogeneity and complicated anisotropy was observed along the body of rod-like specimens.

  14. Ophthalmoplegic migraine with reversible thalamic ischemia by Tc-99m ethylcysteinate dimer brain SPECT

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Jong Ho; Shin, Dong Jin; Kang, Sung Soo [Gachon Medical School, Gil Medical Center, Inchon (Korea, Republic of)

    1999-07-01

    Two patients presented with ophthalmoplegic migraine (OM) underwent EEG, Brain-MRI, cerebral angiography, and Tc-99m ECD SPECT during an attack. Follow-up SPECT was performed after neurologic symptoms resolved. In both cases, SPECT during an attack of ophthalmoplegia and headache demonstrated a significantly decreased regional cerebral blood flow in the thalamus to the side of ophthalmoplegia, which was normalized on the follow-up SPECT during a symptom free recovery phase (Lesion to Non-lesion thalamic ratio=1.19 to 0.96 and 1.16 to 0.98, respectively). The other roentgenographic and laboratory findings were normal. These findings are suggestive the ischemia in the perforators of PCA results in third nerve palsy because the portion of oculomotor nerve behind the cavernous sinus derives its blood supply from small perforating branches of the basilar and PCA. Matched ictal hypoperfusion of the thalamus to the site of ophthalmoplegic migraine is suggestive of the ischemic neuropathy as an etiology of OM.

  15. Comparison of 99Tcm(V)-DMSA and 99Tcm-MIBI scintigraphy in medullary thyroid carcinoma

    International Nuclear Information System (INIS)

    Deng Bo; Xiao Huan; Chen Xiaofeng; Chen Huaming

    2004-01-01

    SPECT scintigraphy is used in 62 patients with medullary thyroid carcinoma (MTC), which are divided into two groups: 32 patients by 99 Tc m (V)-DMSA and 30 patients by 99 Tc m -MIBI. The qualitative analysis and half quantitative analysis are performed to the early and delayed images. Comparing the results with two groups, there is no difference in the masculine rate of MTC primary focus, but the results of 99 Tc m (V)-DMSA scintigraphy is obviously larger than 99 Tc m -MIBI by half quantitative analysis. The results show that the 99 Tc m (V)-DMSA scintigraphy is more predominant than the 99 Tc m -(V)-DMSA scintigraphy may be superior to 99 Tc m -MIBI in MTC primary focus and metastasis focus before surging for MTC patients. (authors)

  16. Adsorption behavior of {sup 99}Mo using AG1-X8 anionic resin

    Energy Technology Data Exchange (ETDEWEB)

    Santos, Jacinete L. dos; Yamaura, Mitiko; Damasceno, Marcos O.; Forbicini, Christina A.L.G.O., E-mail: jlsantos@ipen.br, E-mail: myamaura@ipen.br, E-mail: marcos956@bol.com.br, E-mail: cforbici@ipen.br [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil)

    2013-07-01

    The significant growth in demand of {sup 99}Mo in developed and developing countries, like Brazil, requires large production capacity and availability of this radioisotope. With the global crisis on its supply to Brazil rethought the need to become independent in their production and the solution was to start the Brazilian Multipurpose Reactor (RMB) project, which aims to meet the national demand of {sup 99}Mo for the medical field. This work aims to study the {sup 99}Mo adsorption in AG1-X8 strong anion resin, which is one of the intermediate steps of separation and purification, retaining it in the form of molybdate ions. In process evaluated the resin properties with respect to pH and concentration of {sup 99}Mo in the solution. The adsorbed amount of {sup 99}Mo was determined indirectly by the amount in the supernatant after adsorption and the data fitted to the Langmuir and Freundlich isotherms. Among the models, the Langmuir showed a closer relationship with the experimentally obtained data. This suggests the occurrence of monolayer adsorption and heterogeneous conditions at the surface, where both phenomena can coexist in the experimental conditions tested. (author)

  17. Generator of {sup 99m} Tc with MnO{sub 2} as support of {sup 99} Mo; Generador de {sup 99m} Tc con MnO{sub 2} como soporte del {sup 99}Mo

    Energy Technology Data Exchange (ETDEWEB)

    Granados C, F.; Serrano G, J. [Departamento de Quimica, Instituto Nacional de Investigaciones Nucleares, A.P. 18-1027, 11801 Mexico D.F. (Mexico)

    2002-07-01

    The generator of {sup 99m} Tc with MnO{sub 2} as support of {sup 99} Mo was studied. By mean of static experiments the retention of {sup 99} Mo in MnO{sub 2} in function of the stirring time and of the p H value of the solution of {sup 99} Mo. It was found that the {sup 99} Mo presents 100% of retention in MnO{sub 2} in the rank of p H 3-11 and the balance was reached before of 10 minutes. In dynamic conditions the retention of {sup 99} Mo in MnO{sub 2} at p H=5 was also higher: 99.72%. The generated {sup 99m} Tc can be separated from {sup 99} Mo, adsorbed in MnO{sub 2} packed in the column, using distilled water at p H=5 or NaCl solution at 0.9%. With saline solution the elution yields were greater than 80% and only an aliquot of 5 ml was necessary for obtaining this yield. The better results were obtained when the column was packed with 1 g of MnO{sub 2}. The water and the saline solution were passed through of the column with a flux of 1.25 ml/min. (Author)

  18. The labeling of white blood cells with 99mTc and 111In complexes

    International Nuclear Information System (INIS)

    Hadizad, T.; Najafi, R.

    1993-01-01

    Leukocytes have been labelled with a variety of gamma emitters and labelled (mixed) leukocytes are used clinically to detect and localize sites of abscess in the abdominal area and inflammatory processes surrounding grafts, ulcerative colitis and study of leukocyte kinetics. In this project we used 99m Tc-Sn-Pyp, 99m Tc-Hexamethyl propenylamine oxine, 111 In-Tropolone and 111 In-Oxine Sulfate for the labelling of leukocytes. All the in vitro and in vivo tests have been done to get an optimum condition for injection

  19. Optimization of imaging parameters for SPECT scans of [99mTc]TRODAT-1 using Taguchi analysis.

    Directory of Open Access Journals (Sweden)

    Cheng-Kai Huang

    Full Text Available Parkinson's disease (PD is a neurodegenerative disease characterized by progressive loss of dopaminergic neurons in the basal ganglia. Single photon emission computed tomography (SPECT scans using [99mTc]TRODAT-1 can image dopamine transporters and provide valuable diagnostic information of PD. In this study, we optimized the scanning parameters for [99mTc]TRODAT-1/SPECT using the Taguchi analysis to improve image quality. SPECT scans were performed on forty-five healthy volunteers according to an L9 orthogonal array. Three parameters were considered, including the injection activity, uptake duration, and acquisition time per projection. The signal-to-noise ratio (SNR was calculated from the striatum/occipital activity ratio as an image quality index. Ten healthy subjects and fifteen PD patients were used to verify the optimal parameters. The estimated optimal parameters were 962 MBq for [99mTc]TRODAT-1 injection, 260 min for uptake duration, and 60 s/projection for data acquisition. The uptake duration and time per projection were the two dominant factors which had an F-value of 18.638 (38% and 25.933 (53%, respectively. Strong cross interactions existed between the injection activity/uptake duration and injection activity/time per projection. Therefore, under the consideration of as low as reasonably achievable (ALARA for radiation protection, we can decrease the injection activity to 740 MBq. The image quality remains almost the same for clinical applications.

  20. Study of the elution 99Mo-99mTc generators produced at IPEN-CNEN/SP

    International Nuclear Information System (INIS)

    Lopes, Paula Regina Corain; Osso Junior, Joao Alberto

    2007-01-01

    Over the last years 99m Tc has become a very important asset in modern nuclear medicine, due to the emission of gamma ray of optimal energy (140 keV) and a suitable half-life (6.04 h). A further attribute of 99m Tc is its formation from the decay of 99 Mo and the availability from 99 Mo- 99m Tc generator systems. The most common and practical generator types consist of a chromatographic column packed with aluminium oxide, onto which the highly purified fission product 99 Mo (imported from Canada) is adsorbed in the form of molybdate. 99m Tc is further eluted with saline solution. The objective of this work is to study the performance and the elution profile of 99m Tc from high activity generators in order to decrease molybdenum and aluminium concentration. The experiments involved the use of paper filters and Sep Pak columns and also the changing in the time interval between elutions. 99 Mo breakthrough was measured using a dose calibrator and aluminium by UV-Vis spectrophotometry. The best results were achieved using a Sep Pak column containing neutral aluminium oxide. (author)

  1. 29 CFR 99.105 - Definitions.

    Science.gov (United States)

    2010-07-01

    ... 29 Labor 1 2010-07-01 2010-07-01 true Definitions. 99.105 Section 99.105 Labor Office of the Secretary of Labor AUDITS OF STATES, LOCAL GOVERNMENTS, AND NON-PROFIT ORGANIZATIONS General § 99.105 Definitions. Audit finding means deficiencies which the auditor is required by § 99.510(a) to report in the...

  2. CENRTC Project number-sign 2F3EOA, OCB A-376, acceptance test procedure

    International Nuclear Information System (INIS)

    Akerson, A.W.

    1995-01-01

    This test procedure provides the steps necessary to verify correct functional operation of controls, annunciators, alarms, protective relays and related systems impacted by CENRTC number-sign 2F3E0A, Microwave Transfer Trip Project, modification work performed under work package 6B-93-00041/M. This procedure separates three tests into separate sections: energization of A-376 duplex panel and circuits; SCADA tests; and A-376 local trip tests

  3. Technetium-99 conjugated with methylene diphosphonate (99Tc-MDP) inhibits experimental choroidal neovascularization in vivo and VEGF-induced cell migration and tube formation in vitro.

    Science.gov (United States)

    Lai, Kunbei; Xu, Li; Jin, Chenjin; Wu, Kaili; Tian, Zhen; Huang, Chuangxin; Zhong, Xiaojing; Ye, Haiyun

    2011-07-29

    To investigate the effects of (99)Tc-MDP, a decay product of (99m)Tc-MDP, on the development of choroidal neovascularization (CNV), together with its underlying mechanisms. C57BL/6J mice were used to induce CNV by laser photocoagulation. (99)Tc-MDP at the doses of 0.5 × 10(-1), 1 × 10(-1), and 2 × 10(-1) μg/kg or the same volume of PBS was intraperitoneally injected daily after photocoagulation until the end of the experiment. Seven days after laser injury, mice were perfused with fluorescein-labeled dextran, and areas of CNV were measured. Numbers of infiltrating macrophages, protein levels of VEGF, and inflammation-related molecules including intercellular adhesion molecule (ICAM)-1, tumor necrosis factor (TNF)-α, and matrix metalloproteinases (MMPs) in the RPE-choroid complex were detected 3 days after laser photocoagulation. Effects of (99)Tc-MDP on VEGF-induced endothelial cell migration and tube formation were also studied. Toxicity of (99)Tc-MDP was evaluated in vivo and in vitro. Areas of CNV were significantly suppressed by (99)Tc-MDP treatment without toxicity to the retina compared with PBS treatment in a dose-dependent manner: (99)Tc-MDP treatment of 0.5 × 10(-1) μg/kg (5698.60 ± 1037.70 μm(2)), 1 × 10(-1) μg/kg (3678.34 ± 1328.18 μm(2)), and 2 × 10(-1) μg/kg (2365.78 ± 923.80 μm(2)) suppressed the development of CNV by 36.12%, 58.76%, and 73.48%, respectively, compared with that in the PBS treatment group (8920.36 ± 1097.29 μm(2); P 99)Tc-MDP treatment led to significant inhibition of macrophages infiltrating to CNV together with downregulated protein expressions of VEGF, ICAM-1, TNF-α, and MMP-2. (99)Tc-MDP also showed an inhibitive effect on cell proliferation and VEGF-induced migration and capillary-like tube formation of endothelial cells. Anti-inflammatory treatment with (99)Tc-MDP has therapeutic potential for CNV-related diseases.

  4. Regional differences between {sup 99m}Tc-ECD and {sup 99m}Tc-HMPAO SPET in perfusion changes with age and gender in healthy adults

    Energy Technology Data Exchange (ETDEWEB)

    Inoue, Kentaro; Nakagawa, Manabu; Goto, Ryoi; Kinomura, Shigeo; Sato, Tachio; Sato, Kazunori; Fukuda, Hiroshi [Department of Nuclear Medicine and Radiology, Institute of Development, Aging and Cancer, Tohoku University, 4-1 Seiryomachi Aoba-ku, 980-8575, Sendai (Japan)

    2003-11-01

    A number of studies using single-photon emission tomography (SPET) have shown perfusion changes with age in several cortical and subcortical areas, which might distort the results of perfusion imaging studies of neuropsychiatric disorders. Technetium-99m labelled ethyl cysteinate dimer (ECD) and hexamethylpropylene amine oxime (HMPAO) are both used as markers of cerebral perfusion, but have different pharmacokinetics and retention patterns. The aim of this study was to determine whether age and gender effects on perfusion SPET differ depending on whether {sup 99m}Tc-HMPAO or {sup 99m}Tc-ECD is used. Forty-five subjects (20 male and 25 female, mean age 52.8{+-}6.6 years) were assigned to {sup 99m}Tc-HMPAO SPET (HMPAO group), and 39 subjects (24 male and 15 female, mean age 52.6{+-}6.7 years) to {sup 99m}Tc-ECD SPET (ECD group). SPET images were obtained about 10 min after intravenous injection of approximately 800 MBq {sup 99m}Tc-HMPAO or {sup 99m}Tc-ECD using the same SPET scanner. Three-dimensional volumetric magnetic resonance imaging was performed to as7sess morphological changes in the grey matter. All image processing and statistical analyses were performed using SPM99 software. An area in the right anterior frontal lobe showed an increase in perfusion with age only in the HMPAO group, whereas areas in the bilateral retrosplenial cortex showed decreases in perfusion with age only in the ECD group; neither group showed corresponding changes in the grey matter. The present study shows that different effects of age on perfusion are observed depending on whether {sup 99m}Tc-HMPAO and {sup 99m}Tc-ECD is used. This suggests that the results of perfusion SPET are differently confounded depending on the tracer used, and that perfusion SPET with these tracers has limitations when used in research on subtle perfusion changes. (orig.)

  5. Preparation of clinical-scale 99Mo/99mTc column generator using neutron activated low specific activity 99Mo and nanocrystalline γ-Al2O3 as column matrix.

    Science.gov (United States)

    Chakravarty, Rubel; Ram, Ramu; Dash, Ashutosh; Pillai, M R A

    2012-10-01

    Preparation of clinical-scale (99)Mo/(99m)Tc generator using (n,γ) activated low specific activity (99)Mo and nanocrystalline γ-Al(2)O(3) as a high capacity sorbent matrix is attempted. Nanocrystalline γ-Al(2)O(3) was synthesized by 'solid state mechanochemical' reaction of aluminum nitrate with ammonium bicarbonate. Experimental parameters were optimized to effectively separate (99m)Tc from (99)Mo using this sorbent as the column matrix. The performance features of a 13 GBq (350 mCi) (99)Mo/(99m)Tc generator using this sorbent and (99)Mo produced by (n,γ) route having specific activity 12.9-18.5 GBq/g were evaluated for 10 days. The sorbent possessed the requisite selectivity for (99)Mo and demonstrated a maximum sorption capacity of 200 ± 5mg Mo/g, which is ~10 times higher than that of ordinary acidic alumina. The overall yield of (99m)Tc was >80%, with radionuclidic purity >99.99% and radiochemical purity >99%. The yield of (99m)Tc varied from 7.8 to 2.1 GBq in the eluate for the six days of operation of the generator. The radioactive concentration of (99m)Tc eluted was adequate for the formulation of radiopharmaceuticals. The performance of the generator remained consistent over an extended period of 10 days. The eluted (99m)Tc was suitable for the formulation of (99m)Tc-DMSA and (99m)Tc-EC resulting in high radiolabeling yields (>98%). The effectiveness of γ-Al(2)O(3) as a new generation sorbent in the development of clinically useful (99)Mo/(99m)Tc generator using low specific activity (99)Mo and yielding (99m)Tc with adequate radioactive concentration and high purity suitable for formulation of radiopharmaceuticals is demonstrated. Copyright © 2012 Elsevier Inc. All rights reserved.

  6. Multicolor photometry of the nearby galaxy cluster A119

    International Nuclear Information System (INIS)

    Tian Jintao; Zhou Xu; Jiang Zhaoji; Ma Jun; Wu Zhenyu; Fan Zhou; Zhang Tianmeng; Zou Hu; Yuan Qirong; Wu Jianghua

    2012-01-01

    This paper presents multicolor optical photometry of the nearby galaxy cluster Abell 119 (z = 0.0442) with the Beijing-Arizona-Taiwan-Connecticut system of 15 intermediate bands. Within the BATC field of view of 58' × 58', there are 368 galaxies with known spectroscopic redshifts, including 238 member galaxies (called sample I). Based on the spectral energy distributions of 1376 galaxies brighter than i BATC = 19.5, the photometric redshift technique and the color-magnitude relation of early-type galaxies are applied to select faint member galaxies. As a result, 117 faint galaxies were selected as new member galaxies. Combined with sample I, an enlarged sample (called sample II) of 355 member galaxies is obtained. Spatial distribution and localized velocity structure for two samples demonstrate that A119 is a dynamically complex cluster with at least three prominent substructures in the central region within 1 Mpc. A large velocity dispersion for the central clump indicates a merging along the line of sight. No significant evidence for morphology or luminosity segregations is found in either sample. With the PEGASE evolutionary synthesis model, the environmental effect on the properties of star formation is confirmed. Faint galaxies in the low-density region tend to have longer time scales of star formation, smaller mean stellar ages, and lower metallicities in their interstellar medium, which is in agreement with the context of the hierarchical cosmological scenario. (research papers)

  7. Quality control studies of {sup 99}Mo used in {sup 99}Mo/{sup 99m}Tc generators produced at IPEN/CNEN-SP, Brazil

    Energy Technology Data Exchange (ETDEWEB)

    Said, Daphne S.; Brambilla, Tania P.; Matsuda, Margareth M.N.; Osso Junior, Joao A., E-mail: daphnesaid@usp.br, E-mail: taniabrambilla@yahoo.com.br, E-mail: mmatsuda@ipen.br, E-mail: jaosso@ipen.br [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil)

    2015-07-01

    {sup 99m}Tc is the most used radionuclide in nuclear medicine. In Brazil, the {sup 99}Mo/{sup 99m}Tc generators are produced exclusively by the Center of Radiopharmacy at IPEN-CNEN/SP, by importing {sup 99}Mo from different suppliers. {sup 99}Mo (t{sub 1/2} = 66 h) is a fission product of {sup 235}U, therefore, it can be accompanied by several radioisotopes that are highly prejudicial for human health, demanding a strict quality control of this product for generators safe use. The European Pharmacopoeia established some parameters and limits that evaluate the quality of the solution of sodium [{sup 99}Mo]molybdate, that is used as raw material for generator's production. The European Pharmacopoeia also recommends some analytical methods to perform these evaluations, however, it has been observed difficulties on the implementation of these methods by the generator's producers. These difficulties are probably related to the lack of practicability of the proposed methods and the extensive list of utilized reagents. In this work some procedures of the European Pharmacopoeia's quality control method for {sup 99}Mo were evaluated. Different types of solid phase exchanger cartridges were tested for retention of {sup 99}Mo in 3 different conditions. Cartridges that presented percentages of retention higher than 90% were also tested for separation of {sup 99}Mo from possible contaminants (Ru e Te). The results shown that solid phase exchanger cartridges that presented percentages of retention of Mo higher than 90% also presented significant percentages of retention of Ru and Te. An alternative method for separation of {sup 99}Mo from {sup 131}I (other contaminant) are also proposed. (author)

  8. A {sup 99m}Tc Generator using PZC for (n,{gamma}) {sup 99}Mo

    Energy Technology Data Exchange (ETDEWEB)

    Adang, H G; Mutalib, A; Suparman, I; Hamid,; Purwadi, B; Pancoko, M; Setiowati, S; Yulianti, V; Robertus, D H [Radioisotope Production Center, National Atomic Energy Agency Kawasan PUSPIPTEK, Serpong (Indonesia)

    1998-10-01

    The high performance adsorbent Poly Zirconium Compound (PZC) was produced by Department of Radioisotope, Japan Atomic Energy Research Institute. This compound was developed as an adsorbent for natural Mo (n,{gamma}) {sup 99}Mo-{sup 99m}Tc Generator. In the present paper, we report the performance of the PZC for a {sup 99m}Tc Generator which was focused on the yield, on elution profile and {sup 99}Mo breakthrough. (author)

  9. Contemporary evolution of resistance at the major insecticide target site gene Ace-1 by mutation and copy number variation in the malaria mosquito Anopheles gambiae

    Science.gov (United States)

    Weetman, David; Mitchell, Sara N; Wilding, Craig S; Birks, Daniel P; Yawson, Alexander E; Essandoh, John; Mawejje, Henry D; Djogbenou, Luc S; Steen, Keith; Rippon, Emily J; Clarkson, Christopher S; Field, Stuart G; Rigden, Daniel J; Donnelly, Martin J

    2015-01-01

    Functionally constrained genes are ideal insecticide targets because disruption is often fatal, and resistance mutations are typically costly. Synaptic acetylcholinesterase (AChE) is an essential neurotransmission enzyme targeted by insecticides used increasingly in malaria control. In Anopheles and Culex mosquitoes, a glycine–serine substitution at codon 119 of the Ace-1 gene confers both resistance and fitness costs, especially for 119S/S homozygotes. G119S in Anopheles gambiae from Accra (Ghana) is strongly associated with resistance, and, despite expectations of cost, resistant 119S alleles are increasing significantly in frequency. Sequencing of Accra females detected only a single Ace-1 119S haplotype, whereas 119G diversity was high overall but very low at non-synonymous sites, evidence of strong purifying selection driven by functional constraint. Flanking microsatellites showed reduced diversity, elevated linkage disequilibrium and high differentiation of 119S, relative to 119G homozygotes across up to two megabases of the genome. Yet these signals of selection were inconsistent and sometimes weak tens of kilobases from Ace-1. This unexpected finding is attributable to apparently ubiquitous amplification of 119S alleles as part of a large copy number variant (CNV) far exceeding the size of the Ace-1 gene, whereas 119G alleles were unduplicated. Ace-1 CNV was detectable in archived samples collected when the 119S allele was rare in Ghana. Multicopy amplification of resistant alleles has not been observed previously and is likely to underpin the recent increase in 119S frequency. The large CNV compromised localization of the strong selective sweep around Ace-1, emphasizing the need to integrate CNV analysis into genome scans for selection. PMID:25865270

  10. Lifetime measurement in the yrast band of {sup 119}I

    Energy Technology Data Exchange (ETDEWEB)

    Lobach, Yu.N. [Institute for Nuclear Research UAS, Kiev (Ukraine); Pasternak, A.A. [A.F. Ioffe Physical Technical Institute RAS, St. Petersbourg (Russian Federation); Srebrny, J. [Nuclear Physics Division, IEP, University of Warsaw, Warsaw (Poland)] [and others

    1999-05-01

    The lifetime of levels in the yrast band of {sup 119}I were measured by DSAM and RDM using the {sup 109}Ag({sup 13}C,3n) reaction at E = 54 MeV. The detailed description of data analysis including the stopping power determination and estimation of side feeding time is given. A modified method of RDM data analysis - Recoil Distance Doppler Shape Attenuation (RDDSA) is used. (author) 17 refs, 4 figs, 1 tab

  11. Separation of fission 99Mo by alpha-benzoin oxime precipitation in nitric medium

    International Nuclear Information System (INIS)

    Yamaura, Mitiko; Freitas, Antonio A.; Egute, Nayara dos S.; Camilo, Ruth L.; Araujo, Izilda C.; Forbicini, Christina A.L.G. de O.

    2011-01-01

    Since 2009, the production of generators 99 Mo/ 99 mTc suffers a crisis of global supply due to technical problems of the two reactors which account for 64% of world production of fission 99 Mo. By the project of Brazilian Multipurpose Reactor (RMB), the Brazilian government invests in the construction of the first multipurpose reactor suitable for the domestic production of 99 Mo from LEU targets in order to supply of fission 99 Mo in the coming decades. The IPEN started the research of the technology and production of fission 99 Mo from acid and alkaline dissolutions of Low Enriched Uranium (LEU) targets as well as other used radioisotopes in nuclear medicine. This work is part of the research of the technology of the fission 99 Mo from acid dissolution of the LEU targets that is being developed at the IPEN. In this study the separation of the Mo by precipitation with alpha-benzoin oxime in nitric medium and the recovery by dissolution were investigated. The precipitation studies were performed by batch assays with nitric solution of Mo(VI), containing 99 Mo tracer, and uranyl ions. Influence of concentration of permanganate from 0.03 to 2.5%, dissolution temperature at 30 deg C and 150 deg C and the uranium concentration from 74 g.L -1 to 115 g.L -1 was studied. Results indicated that the precipitation of Mo with alpha-benzoin oxime from nitric medium is highly efficient, and its recovery by dissolution with basic solution of H 2 O 2 gave a high yield. (author)

  12. Hyperfine magnetic fields at 57Fe and 119Sn nuclei in the Fe48Rh52 alloy under pressure

    International Nuclear Information System (INIS)

    Nikolaev, I.N.; Potapov, V.N.; Bezotosnyj, I.Yu.; Mar'in, V.P.

    1978-01-01

    The pressure dependences of the hyperfine magnetic fields, H, and isomer shifts epsilon at the 57 Fe and 119 Sn nuclei in the Fe 48 Rh 52 alloy with an admixture of approximately 1 at. % Sn are measured by the Moessbauer effect technique. Under pressure epsilon decreases this signifying an increase (for 57 Fe) or decrease (for 119 Sn) of the s-electron density at the nuclei. In the ferromagnetic (FM) state at 398 K, ΔH/HΔp=(-2.8+-0.2)x10 -3 kbar -1 for 57 Fe and ΔH/HΔp=(-4.8+-0.8)x10 -3 kbar -1 for 119 Sn. In the antiferromagnetic (AFM) state at 78 K, ΔH/HΔp approximately 0 for 57 Fe and ΔH/HΔp=(-6.2+-1.0)x10 -3 kbar -1 for 119 Sn. The results for 57 Fe in the FM state can be ascribed to the strong dependence of the alloy matrix magnetization on the pressure and in the AFM state to the absence of local polarization of s-similar collectivized electrons and to the independence of the magnetic moments of the Fe ions of pressure. The causes of the different effect of pressure on the magnetic moments of Fe ions in the FM and AFM states are discussed. The results for 119 Sn in the FM and AFM states of the alloy are in agreement with the model of hyperfine fields at impurity Sn atoms in the magnetic matrices proposed earlier. The radial dependence of the hyperfine field at the 119 Sn nuclei in the AFM state is estimated and it is found that H(r) is stronger than r -9

  13. Targeting osteomyelitis with complete [99mTc]besilesomab and fragmented [99mTc]sulesomab antibodies: kinetic evaluations

    International Nuclear Information System (INIS)

    GRATZ, Stefan; KEMKE, Bendix; KEIZE, Patrik; KAMPEN, Wim U.; LUSTER, Markus; HÖFFKEN, Helmut

    2016-01-01

    The aim of this retrospective study was to compare the targeting of “pure” osteomyelitis (i.e., without surrounding soft tissue infection) by directly 99mTc-labelled complete immunoglobulin G (IgG) monoclonal antibody (MAb) ([99mTc]besilesomab) and by directly 99mTc-labelled fragment antigen-binding (FAb) MAb ([99mTc]sulesomab) in relation to their kinetic fate. A total of 73 patients with “pure” osteomyelitis were examined with [99mTc]besilesomab, (Scintimun®, IBA/CIS bio international, Saclay, France; N.=38) and [99mTc]sulesomab (LeukoScan®, Immunomedics Inc., Morris Plains, NJ, USA; N.=35). Kinetic data were deduced from whole-body and single-photon emission computed tomographic scans, performed 10 minutes to 24 hour p.i. (region-of-interest technique [ROI]). In targeting “pure” osteomyelitis, sensitivities at 1-4 hours were found to be higher for [99mTc]sulesomab (44% and 80% for [99mTc]besilesomab and [99mTc]sulesomab, respectively) but at significantly lower target/background (T/B) ratios than with [99mTc]besilesomab (1.8±0.3 versus 1.4±0.5 for [99mTc]besilesomab and [99mTc]sulesomab respectively; P<0.01). With [99mTc]besilesomab, there was a continuous osteomyelitis uptake over 24 hours, whereas with [99mTc]sulesomab, the maximal uptake occurred mostly within 1-4 hours, with subsequent clearance being slower for antigen-bound activity than for nonspecific background. Hence, diagnosis was possible mostly after 4h with [99mTc]sulesomab but often not before 24 hours with [99mTc]besilesomab, the later increasing significantly (P<0.01) in sensitivity (87% and 84% for [99mTc]besilesomab and [99mTc]sulesomab, respectively). These results show that the higher sensitivity of [99mTc]sulesomab in osteomyelitis targeting at earlier p.i. times does not rely on an increased antibody uptake but on a more rapid clearance of nonspecific background activity due to faster metabolism and excretion. Intact [99mTc]besilesomab show a slow, continuous uptake

  14. Synthesis and decay process of superheavy nuclei with Z=119-122 via hot-fusion reactions

    Energy Technology Data Exchange (ETDEWEB)

    Ghahramany, N.; Ansari, A. [Shiraz University, Department of Physics and Biruni Observatory, College of Science, Shiraz (Iran, Islamic Republic of)

    2016-09-15

    In this research article attempts have been made to calculate the superheavy-nuclei synthesis characteristics including, the potential energy parameters, fusion probability, fusion and evaporation residue (ER) cross sections as well as, decay properties of compound nucleus and the residue nuclei formation probability for elements with Z=119-122 by using the hot-fusion reactions. It is concluded that, although a selection of double magic projectiles such as {sup 48}Ca with high binding energy, simplifies the calculations significantly due to spherical symmetric shape of the projectile, resulting in high evaporation residue cross section, unfortunately, nuclei with Z > 98 do not exist in quantities sufficient for constructing targets for the hot-fusion reactions. Therefore, practically our selection is fusion reactions with titanium projectile because the mass production of target nuclei for experimental purposes is more feasible. Based upon our findings, it is necessary, for new superheavy-nuclei production with Z > 119, to use neutron-rich projectiles and target nuclei. Finally, the maximal evaporation residue cross sections for the synthesis of superheavy elements with Z=119-122 have been calculated and compared with the previously founded ones in the literature. (orig.)

  15. Method of producing molybdenum-99

    Science.gov (United States)

    Pitcher, Eric John

    2013-05-28

    Method of producing molybdenum-99, comprising accelerating ions by means of an accelerator; directing the ions onto a metal target so as to generate neutrons having an energy of greater than 10 MeV; directing the neutrons through a converter material comprising techentium-99 to produce a mixture comprising molybdenum-99; and, chemically extracting the molybdenum-99 from the mixture.

  16. Development of an image reconstruction algorithm for a few number of projection data

    International Nuclear Information System (INIS)

    Vieira, Wilson S.; Brandao, Luiz E.; Braz, Delson

    2007-01-01

    An image reconstruction algorithm was developed for specific cases of radiotracer applications in industry (rotating cylindrical mixers), involving a very few number of projection data. The algorithm was planned for imaging radioactive isotope distributions around the center of circular planes. The method consists of adapting the original expectation maximization algorithm (EM) to solve the ill-posed emission tomography inverse problem in order to reconstruct transversal 2D images of an object with only four projections. To achieve this aim, counts of photons emitted by selected radioactive sources in the plane, after they had been simulated using the commercial software MICROSHIELD 5.05, constitutes the projections and a computational code (SPECTEM) was developed to generate activity vectors or images related to those sources. SPECTEM is flexible to support simultaneous changes of the detectors's geometry, the medium under investigation and the properties of the gamma radiation. As a consequence of the code had been followed correctly the proposed method, good results were obtained and they encouraged us to continue the next step of the research: the validation of SPECTEM utilizing experimental data to check its real performance. We aim this code will improve considerably radiotracer methodology, making easier the diagnosis of fails in industrial processes. (author)

  17. Development of an image reconstruction algorithm for a few number of projection data

    Energy Technology Data Exchange (ETDEWEB)

    Vieira, Wilson S.; Brandao, Luiz E. [Instituto de Engenharia Nuclear (IEN-CNEN/RJ), Rio de Janeiro , RJ (Brazil)]. E-mails: wilson@ien.gov.br; brandao@ien.gov.br; Braz, Delson [Universidade Federal do Rio de Janeiro (UFRJ), RJ (Brazil). Coordenacao dos Programa de Pos-graduacao de Engenharia (COPPE). Lab. de Instrumentacao Nuclear]. E-mail: delson@mailhost.lin.ufrj.br

    2007-07-01

    An image reconstruction algorithm was developed for specific cases of radiotracer applications in industry (rotating cylindrical mixers), involving a very few number of projection data. The algorithm was planned for imaging radioactive isotope distributions around the center of circular planes. The method consists of adapting the original expectation maximization algorithm (EM) to solve the ill-posed emission tomography inverse problem in order to reconstruct transversal 2D images of an object with only four projections. To achieve this aim, counts of photons emitted by selected radioactive sources in the plane, after they had been simulated using the commercial software MICROSHIELD 5.05, constitutes the projections and a computational code (SPECTEM) was developed to generate activity vectors or images related to those sources. SPECTEM is flexible to support simultaneous changes of the detectors's geometry, the medium under investigation and the properties of the gamma radiation. As a consequence of the code had been followed correctly the proposed method, good results were obtained and they encouraged us to continue the next step of the research: the validation of SPECTEM utilizing experimental data to check its real performance. We aim this code will improve considerably radiotracer methodology, making easier the diagnosis of fails in industrial processes. (author)

  18. 99mTc-MIBI, 99mTc-tetrofosmin and 99mTc-Q12 in vitro and in vivo

    International Nuclear Information System (INIS)

    Bernard, Bert F.; Krenning, Eric P.; Breeman, Wout A. P.; Ensing, Geert; Benjamins, Harry; Bakker, Willem H.; Visser, Theo J.; Jong, Marion de

    1998-01-01

    The aim of this study was to compare uptake of 99m Tc-MIBI, 99m Tc-tetrofosmin and 99m Tc-Q12 in vitro and biodistribution in vivo in rats. In vitro, uptake decreased in the order MIBI→tetrofosmin→Q12. Uptake of MIBI and tetrofosmin, but not of Q12, in cultured tumor cells was dependent on the plasma membrane and mitochondrial potential. In vivo, heart uptake of all three compounds was high and stable. Tumor uptake decreased in the order MIBI→Q12→tetrofosmin and the tumor/blood ratio in the order MIBI→tetrofosmin→Q12

  19. MicroRNA-99 family members suppress Homeobox A1 expression in epithelial cells.

    Science.gov (United States)

    Chen, Dan; Chen, Zujian; Jin, Yi; Dragas, Dragan; Zhang, Leitao; Adjei, Barima S; Wang, Anxun; Dai, Yang; Zhou, Xiaofeng

    2013-01-01

    The miR-99 family is one of the evolutionarily most ancient microRNA families, and it plays a critical role in developmental timing and the maintenance of tissue identity. Recent studies, including reports from our group, suggested that the miR-99 family regulates various physiological processes in adult tissues, such as dermal wound healing, and a number of disease processes, including cancer. By combining 5 independent genome-wide expression profiling experiments, we identified a panel of 266 unique transcripts that were down-regulated in epithelial cells transfected with miR-99 family members. A comprehensive bioinformatics analysis using 12 different sequence-based microRNA target prediction algorithms revealed that 81 out of these 266 down-regulated transcripts are potential direct targets for the miR-99 family. Confirmation experiments and functional analyses were performed to further assess 6 selected miR-99 target genes, including mammalian Target of rapamycin (mTOR), Homeobox A1 (HOXA1), CTD small phosphatase-like (CTDSPL), N-myristoyltransferase 1 (NMT1), Transmembrane protein 30A (TMEM30A), and SWI/SNF-related matrix-associated actin-dependent regulator of chromatin subfamily A member 5 (SMARCA5). HOXA1 is a known proto-oncogene, and it also plays an important role in embryonic development. The direct targeting of the miR-99 family to two candidate binding sequences located in the HOXA1 mRNA was confirmed using a luciferase reporter gene assay and a ribonucleoprotein-immunoprecipitation (RIP-IP) assay. Ectopic transfection of miR-99 family reduced the expression of HOXA1, which, in consequence, down-regulated the expression of its downstream gene (i.e., Bcl-2) and led to reduced proliferation and cell migration, as well as enhanced apoptosis. In summary, we identified a number of high-confidence miR-99 family target genes, including proto-oncogene HOXA1, which may play an important role in regulating epithelial cell proliferation and migration during

  20. MicroRNA-99 family members suppress Homeobox A1 expression in epithelial cells.

    Directory of Open Access Journals (Sweden)

    Dan Chen

    Full Text Available The miR-99 family is one of the evolutionarily most ancient microRNA families, and it plays a critical role in developmental timing and the maintenance of tissue identity. Recent studies, including reports from our group, suggested that the miR-99 family regulates various physiological processes in adult tissues, such as dermal wound healing, and a number of disease processes, including cancer. By combining 5 independent genome-wide expression profiling experiments, we identified a panel of 266 unique transcripts that were down-regulated in epithelial cells transfected with miR-99 family members. A comprehensive bioinformatics analysis using 12 different sequence-based microRNA target prediction algorithms revealed that 81 out of these 266 down-regulated transcripts are potential direct targets for the miR-99 family. Confirmation experiments and functional analyses were performed to further assess 6 selected miR-99 target genes, including mammalian Target of rapamycin (mTOR, Homeobox A1 (HOXA1, CTD small phosphatase-like (CTDSPL, N-myristoyltransferase 1 (NMT1, Transmembrane protein 30A (TMEM30A, and SWI/SNF-related matrix-associated actin-dependent regulator of chromatin subfamily A member 5 (SMARCA5. HOXA1 is a known proto-oncogene, and it also plays an important role in embryonic development. The direct targeting of the miR-99 family to two candidate binding sequences located in the HOXA1 mRNA was confirmed using a luciferase reporter gene assay and a ribonucleoprotein-immunoprecipitation (RIP-IP assay. Ectopic transfection of miR-99 family reduced the expression of HOXA1, which, in consequence, down-regulated the expression of its downstream gene (i.e., Bcl-2 and led to reduced proliferation and cell migration, as well as enhanced apoptosis. In summary, we identified a number of high-confidence miR-99 family target genes, including proto-oncogene HOXA1, which may play an important role in regulating epithelial cell proliferation and

  1. In-house cyclotron production of high-purity Tc-99m and Tc-99m radiopharmaceuticals.

    Science.gov (United States)

    Martini, Petra; Boschi, Alessandra; Cicoria, Gianfranco; Zagni, Federico; Corazza, Andrea; Uccelli, Licia; Pasquali, Micòl; Pupillo, Gaia; Marengo, Mario; Loriggiola, Massimo; Skliarova, Hanna; Mou, Liliana; Cisternino, Sara; Carturan, Sara; Melendez-Alafort, Laura; Uzunov, Nikolay M; Bello, Michele; Alvarez, Carlos Rossi; Esposito, Juan; Duatti, Adriano

    2018-05-30

    In the last years, the technology for producing the important medical radionuclide technetium-99m by cyclotrons has become sufficiently mature to justify its introduction as an alternative source of the starting precursor [ 99m Tc][TcO 4 ] - ubiquitously employed for the production of 99m Tc-radiopharmaceuticals in hospitals. These technologies make use almost exclusively of the nuclear reaction 100 Mo(p,2n) 99m Tc that allows direct production of Tc-99m. In this study, it is conjectured that this alternative production route will not replace the current supply chain based on the distribution of 99 Mo/ 99m Tc generators, but could become a convenient emergency source of Tc-99m only for in-house hospitals equipped with a conventional, low-energy, medical cyclotron. On this ground, an outline of the essential steps that should be implemented for setting up a hospital radiopharmacy aimed at the occasional production of Tc-99m by a small cyclotron is discussed. These include (1) target production, (2) irradiation conditions, (3) separation/purification procedures, (4) terminal sterilization, (5) quality control, and (6) Mo-100 recovery. To address these issues, a comprehensive technology for cyclotron-production of Tc-99m, developed at the Legnaro National Laboratories of the Italian National Institute of Nuclear Physics (LNL-INFN), will be used as a reference example. Copyright © 2018 Elsevier Ltd. All rights reserved.

  2. Evaluation of '99Mo presence in eluates of 99mTc used in nuclear medicine

    International Nuclear Information System (INIS)

    Ribeiro, Bianca da Silva

    2010-01-01

    Tc-99m is used for diagnostic imaging in nuclear medicine through SPECT technique. It is obtained by the elution of 99 Mo/ 99m Tc generators. During the elution process 99 Mo can be extracted becoming a radionuclidic impurity. One of the quality parameters of the eluate is the radionuclidic purity, MBT (molybdenum break through), defined as the ratio between 99 Mo and 99m Tc activities in the eluate. The North-American and European pharmacopoeias restrict the 99 Mo content, respectively, in 0.015 e 0.1% and, according to the International Atomic Energy Agency (IAEA), the activity ratio at the moment of administration of the radiopharmaceutical to the patient, should not exceed 0.015%. In Brazil, the control of such parameter is not obliged in official regulations. Thus, the objective of this work is to evaluate the occurrence of 99 Mo in 99m Tc eluates. It was initially optimized a methodology to determine the activity of 99 Mo in eluate samples. Efficiency curves were obtained for a NaI (Tl) 8'' x 4'' scintillation detector installed at the In Vivo Monitoring Laboratory (LABMIV-IRD). The methodology has been validated through the measurement of a 99 Mo standard liquid source calibrated at the National Metrology Laboratory for Ionizing Radiation (LNMRI-IRD). The samples analyzed in this work were gently supplied by 5 Nuclear Medicine Clinics located in the city of Rio de Janeiro. The activities of 99 mTc and 99 Mo in those samples have been measured respectively at the clinics and at the LABMIV. By applying a standardized methodology, the ration between the activities were calculated. The results show that 147 out of 174 samples presented 99 Mo activities above the minimum detectable activity of the technique. On the other hand, only 2 out of 147 samples surpassed the MBT limit suggested by the IAEA and have been detected in samples eluted from generators of 750 mCi. In one of the samples, eluted from a generator of 1000 mCi, the calculated MBT value was very close

  3. A novel electrochemical technique for the production of clinical grade 99mTc using (n, γ)99Mo

    International Nuclear Information System (INIS)

    Chakravarty, Rubel; Dash, Ashutosh; Venkatesh, Meera

    2010-01-01

    Introduction: In order to meet the growing demand for 99m Tc and to reduce the reliance on fission-produced 99 Mo, an electrochemical pathway for accessing 99m Tc through the (n, γ) 99 Mo was explored as a back-up measure and to supplement 99m Tc supply for radiopharmaceuticals application. Methods: 99m Tc from an equilibrium mixture of 99 Mo/ 99m Tc was selectively deposited on a platinum cathode in an electrochemical cell by applying optimal voltage and stripped back again into the 0.9% saline solution. The radiochemical and radionuclidic purity of the product were determined using standard techniques. 99m Tc thus obtained was used for labeling standard ligands such as dimercaptosuccinic acid (DMSA) and ethylene dicysteine (EC), to ascertain the usability. Results: Selective deposition of 99m Tc on the platinum electrode was achieved at a potential of 5 V over a period of 1 h in NaOH electrobath. The overall yield of 99m Tc was >90%, with >99.99% radionuclidic purity and >99% radiochemical purity. The performance of the generator remained consistent over a period of 10 days. The compatibility of the product in the preparation of 99m Tc-labeled formulations such as 99m Tc-DMSA and 99m Tc-EC was found to be satisfactory in terms of high labeling yields (>98%). Conclusion: A novel and attractive method has been developed to obtain highly concentrated 99m Tc, without using fission-produced 99 Mo.

  4. Separation of sup(99m)Tc from 99MoO3

    International Nuclear Information System (INIS)

    Tomicic, M.

    1977-07-01

    At the present time sup(99m)Tc is widely used in nuclear medicine and its uses are increasing. It can be produced by various methods, and of those most frequently used today two have special features making them particularly applicable to the large-scale production of instant sup(99m)Tc - these are solvent extraction with methyl-ethyl-ketone and the sublimation methods. This report presents a bibliographic review of these methods, their main perfomance parameters, and experience obtained from the development and operation of a sublimation generator. Separation of sup(99m)Tc from irradiated MoO 3 was carried out with high yields (75-95%) after multiple repetition of the separation process with molybdenum trioxide heated for half an hour at a maximum temperature of 850-890 deg C in an air flow. The activity ratio of molybdenum in the separated sup(99m)Tc was of the order of 4 x 10 -5 . (author)

  5. Influence of the electrolyte in the fixation of {sup 99} Mo in hydroxyapatite as matrix of the {sup 99} Mo/ {sup 99m} Tc generator; Influencia del electrolito en la fijacion de {sup 99} Mo en hidroxiapatita coma matriz del generador {sup 99} Mo/ {sup 99m} Tc

    Energy Technology Data Exchange (ETDEWEB)

    Vazquez G, S.; Badillo A, V.E. [UAZ, Zacatecas (Mexico); Monroy G, F. [ININ, 52045 Ocoyoacac, Estado de Mexico (Mexico)]. e-mail: s_vazgro@hotmail.com

    2005-07-01

    The more used isotope at the moment in the services of nuclear medicine in the world is the technetium-99m. The {sup 99m} Tc emitts gamma rays of 141 keV and it semi disintegration period is of six hours, given it short half life, to produce it is necessary to order generators that are systems that allow to separate periodically at the {sup 99m}Tc of the {sup 99} Mo by means of chromatographic techniques. In this work it is sought to evaluate the use of the hydroxyapatite, to separate molybdates {sup 99} MoO{sub 4}{sup 2} of pertechnetates {sup 99m}TcO{sub 4}{sup -} and to be able to determine if it is feasible their use for to build generators of {sup 99m} Tc. With this purpose preliminary tests to know the likeness of the hydroxyapatite for the molybdates in function of the pH value, in different solutions were carried out: one of NaCl 0.9%, NaCl 2% and CaCl{sub 2} 0.01 M. The obtained results in a NaCl 0.9% solution and at to 2% to different pH values of the solution, shows that the fixation of the molybdate ions (MoO{sub 4}{sup -2}) it is worthless to basic pH values of (9-11), as long as in solution of CaCI{sub 2} 0.01 M show a considerable retention of molybdate ions. (Author)

  6. Localizing diagnosis of hyperfunctional parathyroid glands using 99mTc-methoxyisobutylisonitrile (MIBI)

    International Nuclear Information System (INIS)

    Katagiri, Makoto; Yokobayashi, Tsuneo; Fukunaga, Masao; Harada, Tanekazu.

    1995-01-01

    In this study, we investigated the detectability of hyperfunctional parathyroid gland(s) by subtraction scintigraphy using 99m Tc-methoxyisobutylisonitrile and 99m Tc-pertechnetate (MIBI-Tc), and compared the findings with those obtained by conventional subtraction scintigraphy using 201 Tl-Cl and 99m Tc-pertechnetate (Tl-Tc), ultrasonography (US) and computed tomography (CT). The subjects were 6 patients with primary hyperparathyroidism (PHP) with a single adenoma and 13 with renal hyperparathyroidism (RHP) with hyperplasia receiving chronic maintenance hemodialysis. All of the patients underwent surgery, and the number and location of the abnormal parathyroid glands were confirmed. The numbers of resected parathyroid glands were 6 in the PHP group and 52 in the RHP group. In the PHP group, the detectability of hyperfunctional parathyroid glands with MIBI-Tc, Tl-Tc, US and CT was 83.3%, 100%, 83.3% and 83.3%, respectively. In the RHP group, on the other hand, these values were lower than those in the PHP group: 51.9%, 44.2%, 57.7% and 56.3%, respectively. No statistically significant differences were observed among the diagnostic tools in either group. As 99m Tc-MIBI has many physiological advantages over 201 Tl-Cl as a radiotracer, this radionuclide is expected to become useful for the detection of hyperfunctional parathyroid glands. (author)

  7. 32 CFR 99.3 - General definitions.

    Science.gov (United States)

    2010-07-01

    ... 32 National Defense 1 2010-07-01 2010-07-01 false General definitions. 99.3 Section 99.3 National... PROCEDURES FOR STATES AND LOCALITIES TO REQUEST INDEMNIFICATION § 99.3 General definitions. For the purposes of §§ 99.1 through 99.9 of this part: Criminal history record information: information collected by...

  8. Preparation and biodistribution of 99Tcm-lomefloxacin in inflammatory model mice

    International Nuclear Information System (INIS)

    Liu Jianfeng; Han Jiankui; Zhang Chao; Hou Guihua

    2009-01-01

    Objective: The study of 99 TC m -ciprofloxacin, a fluoroquinolones antibiotic, as a tracer for infection and inflammation imaging has been reported. The aim of this study was to investigate the radio-labeling and biodistribution of lomefloxacin (fluoroquinolones analogue) as an inflammatory imaging agent. Methods: 99 TC m -lomefloxacin was prepared and it underwent quality control with thin layer chromatography (TLC). The different labeling conditions were compared. The radiochemical purity, labeling efficiency, stability and lipid/water partition coefficient of 99 TC m -lomefloxacin were measured. The binding activities of 99 TC m -lomefloxacin with Staphylococci aureus (S. aureus)in vitro were tested. 99 TC m -lomefloxacin was in-ieeted through tail vein in the S. aureus-induced inflammatory model mice. The mice were sacrificed and their blood. inflammatory muscles. major organs were taken out at different time after tracer inieetion. Then the radioactivity count of these samples was measured to observe biodistribution. Whole-body radioauto-graphic images were obtained with storage phosphor screen system. Variance analysis using Concise Statis-tics 10.3 software was performed. Results: 99 TC m -lomefloxacin was lipid-soluble with labeling efficiency of 97.5%. The radiochemieal purity was more than 95% at 6 h after storing in room temperature. In vitro test 99 TC m -lomefloxacin showed good binding characteristic with S. auaresu and was positively correlated with the colony number of S. aureus. The highest binding appeared at 1 h. In vivo 99 TC 5 m-lomefloxacin apparently accumulated in inflammatory tissues at 2 h after tracer injection with the uptake ratio of 4.07 ± 1.05 in inflammatory muscles to control muscles. Whole-body autoradiography showed that all inflammation foci were visualized. Conclusion: 99 TC m -lomefloxacin may be a novel potential agent for inflammatory imaging. (authors)

  9. Exotic decay modes of odd-Z (105-119) superheavy nuclei

    Energy Technology Data Exchange (ETDEWEB)

    Rajeswari, N.S. [Bharathiar University, Department of Physics, Coimbatore (India); Avinashilingam Institute for Home Science and Higher Education for Women - University, Department of Physics, Coimbatore (India); Balasubramaniam, M. [Bharathiar University, Department of Physics, Coimbatore (India)

    2014-06-15

    Half-lives of proton emission for proton emitters with Z = 51 to 83 are calculated, in the frame-work of unified fission model with the penetrability calculated using the WKB approximation. For all the ground and isomeric state of the proton, the deformation degree of freedom is included. Calculated half-lives are in good agreement with the experimental ones. Experimentally for a few isotopes, proton and alpha branches are reported. Hence we have calculated the half-lives of alpha decay for these elements. For parent nuclei {sup 157}Ta, {sup 166}Ir, {sup 167}Ir, {sup 176}Tl and {sup 177}Tl, the alpha decay mode is preferred over the proton emission. Further, the calculations are extended to find half-lives of superheavy element with odd proton number in the range Z = 105 to 119, for both proton, alpha and for a few cluster decays. Calculations on superheavy elements reveal that cluster radioactivity has half-lives comparable with proton emissions. It is found that proton emission is the primary competing decay mode with respect to alpha decay for superheavy elements. Among considered clusters, {sup 12}C, {sup 20}Ne and {sup 24}Mg are found to have lowest half-lives among other N = Z clusters and for a few clusters the half-lives are found to be comparable with that of proton emission. (orig.)

  10. Measurement and Estimation of the 99Mo Production Yield by 100Mo(n,2n)99Mo

    Science.gov (United States)

    Minato, Futoshi; Tsukada, Kazuaki; Sato, Nozomi; Watanabe, Satoshi; Saeki, Hideya; Kawabata, Masako; Hashimoto, Shintaro; Nagai, Yasuki

    2017-11-01

    We, for the first time, measured the yield of 99Mo, the mother nuclide of 99mTc used in nuclear medicine diagnostic procedures, produced by the 100Mo(n,2n)99Mo reaction with accelerator neutrons. The neutrons with a continuous energy spectrum from the thermal energy up to about 40 MeV were provided by the C(d,n) reaction with 40 MeV deuteron beams. It was proved that the 99Mo yield agrees with that estimated by using the latest data on neutrons from the C(d,n) reaction and the evaluated cross section of the 100Mo(n,2n)99Mo reaction given in the Japanese Evaluated Nuclear Data Library. On the basis of the agreement, a systematic calculation was carried out to search for an optimum condition that enables us to produce as much 99Mo as possible with a good 99Mo/100Mo value from an economical point of view. The calculated 99Mo yield from a 150 g 100MoO3 sample indicated that about 30% of the demand for 99Mo in Japan can be met with a single accelerator capable of 40 MeV, 2 mA deuteron beams. Here, by referring to an existing 18F-fluorodeoxyglucose (FDG) distribution system we assumed that 99mTc radiopharmaceuticals formed after separating 99mTc from 99Mo can be delivered to hospitals from a radiopharmaceutical company within 6 h. The elution of 99mTc from 99Mo twice a day would meet about 50% of the demand for 99Mo.

  11. Environmental behavior of technetium-99

    International Nuclear Information System (INIS)

    Turcotte, M.D.S.

    1982-12-01

    This report presents a review of the literature on technetium-99. The chemical and physical properties of some technetium compounds are considered, and a discussion of possible source terms is included. Literature on the environmental behavior of technetium is presented, including its behavior in the bodies of animals and humans. The primary sources of Tc-99 in the environment are fallout from atomic detonations and releases from nuclear fuel reprocessing plants. The environmental behavior of technetium-99 has been studied predominantly with respect to movement in soil and accumulation in plants. There is a surprising scarcity of data on behavior of Tc-99 in the atmosphere and in aquatic systems. Additional work needs to be conducted in these two areas to determine behavior and to acquire baseline concentration data. Much of the soil work has produced contradictory results. In-depth studies of holdup mechanisms for Tc-99 in both geological repositories and soil need to be conducted. Since plants represent a potential bioaccumulation of Tc-99, plant uptake studies of Tc-99 under field conditions also need to be done

  12. {sup 201}Tl, {sup 99m}Tc-MIBI, {sup 99m}Tc-tetrofosmin and {sup 99m}Tc-furifosmin: relative retention and clearance kinetics in retrogradely perfused guinea pig hearts

    Energy Technology Data Exchange (ETDEWEB)

    Schaefer, Wolfgang M.; Moka, Detlef E-mail: detlef.moka@uni-koeln.de; Brockmann, Holger A.; Schomaecker, Klaus; Schicha, Harald

    2002-02-01

    Myocellular kinetics of {sup 201}Tl, {sup 99m}Tc-MIBI, {sup 99m}Tc-tetrofosmin and {sup 99m}Tc-furifosmin were investigated using retrogradely-perfused guinea-pig hearts. Relative retention decreased in the order {sup 99m}Tc-MIBI {yields}{yields} implies {sup 99m}Tc-tetrofosmin {yields}{yields} implies {sup 99m}Tc-furifosmin. {sup 201}Tl and {sup 99m}Tc-MIBI exhibited bi- (t1,t2), {sup 99m}Tc-tetrofosmin and {sup 99m}Tc-furifosmin triexponential (t1,t2,t3) time-activity-curves. Latest-phase elimination-half-life increased from {sup 201}Tl (t2) {yields}{yields} implies {sup 99m}Tc-MIBI (t2) {yields}{yields} implies {sup 99m}Tc-tetrofosmin (t3) {yields}{yields} implies {sup 99m}Tc-furifosmin (t3), showing a significant increase in deteriorating myocardium for all tracers but {sup 99m}Tc-furifosmin. Delayed elimination in deteriorating myocardium explains at least partly the redistribution phenomenon of {sup 201}Tl, and suggests a similar phenomenon for {sup 99m}Tc-MIBI and {sup 99m}Tc-tetrofosmin.

  13. Determination of 99Mo in 99mTc eluates used in nuclear medicine centers in Rio de Janeiro

    International Nuclear Information System (INIS)

    Ribeiro, Bianca da S.; Souza, Raphael S.S.; Lucena, Eder A.; Dantas, Ana Leticia A.; Dantas, Bernardo M.

    2009-01-01

    99m Tc is used in nuclear medicine for image diagnoses with SPECT. It is obtained from the elution of molybdenum-99/technetium-99m ( 99 Mo/ 99m Tc) generators. During the elution, 99 Mo can detach from the column, passing through the filter and mixing in the solution of pertechnetate eluate and becoming a radionuclidic impurity. The presence of molybdenum in the radiopharmaceutical solution imparts an unnecessary radiation dose to the patient, since its half-life is relatively long (66 hours) and it emits beta particles and high-energy photons of (740 keV). A parameter that indicates the quality of the eluates is the radionuclidic purity, the MBT (molybdenum break through), defined as the ratio between 99 Mo and 99m Tc activities in the eluate. The American and the European Pharmacopoeias restrict 99 Mo content to respectively 0.015% and 0.1% activity ratio 99 Mo/ 99m Tc at the time of the administration to the patient. In Brazil, this parameter is not controlled by official regulations. The objective of this work is to determine the presence of 99 Mo in the eluates used in nuclear medicine centers (NMC). The activity measurements of 99 Mo were performed with a NaI(Tl)8''x4'' scintillation detector installed in the IRD whole body counter. The activity of 99m Tc was measured in the NMC where the eluates were collected and, using the established calculations, it was determined the activity ratio 99 Mo/ 99m Tc. The eluate samples were kindly supplied by the participating NMC of Rio de Janeiro. All measurements indicated the presence of 99 Mo. It is concluded that the technique is sensitive to detect 99 Mo in 99m Tc eluates and permits to verify the quality of the generators used in NMC evaluated in this study. (author)

  14. Influence of the electrolyte in the fixation of 99 Mo in hydroxyapatite as matrix of the 99 Mo/ 99m Tc generator

    International Nuclear Information System (INIS)

    Vazquez G, S.; Badillo A, V.E.; Monroy G, F.

    2005-01-01

    The more used isotope at the moment in the services of nuclear medicine in the world is the technetium-99m. The 99m Tc emitts gamma rays of 141 keV and it semi disintegration period is of six hours, given it short half life, to produce it is necessary to order generators that are systems that allow to separate periodically at the 99m Tc of the 99 Mo by means of chromatographic techniques. In this work it is sought to evaluate the use of the hydroxyapatite, to separate molybdates 99 MoO 4 2 of pertechnetates 99m TcO 4 - and to be able to determine if it is feasible their use for to build generators of 99m Tc. With this purpose preliminary tests to know the likeness of the hydroxyapatite for the molybdates in function of the pH value, in different solutions were carried out: one of NaCl 0.9%, NaCl 2% and CaCl 2 0.01 M. The obtained results in a NaCl 0.9% solution and at to 2% to different pH values of the solution, shows that the fixation of the molybdate ions (MoO 4 -2 ) it is worthless to basic pH values of (9-11), as long as in solution of CaCI 2 0.01 M show a considerable retention of molybdate ions. (Author)

  15. Utility of the Static-99 and Static-99R With Latino Sex Offenders.

    Science.gov (United States)

    Leguízamo, Alejandro; Lee, Seung C; Jeglic, Elizabeth L; Calkins, Cynthia

    2017-12-01

    The predictive validity of the Static-99 measures with ethnic minorities in the United States has only recently been assessed with mixed results. We assessed the predictive validity of the Static-99 and Static-99R with a sample of Latino sex offenders ( N = 483) as well as with two subsamples (U.S.-born, including Puerto Rico, and non-U.S.-born). The overall sexual recidivism rate was very low (1.9%). Both the Static-99 measures were able to predict sexual recidivism for offenders born in the United States and Puerto Rico, but neither was effective in doing so for other Latino immigrants. Calibration analyses ( N = 303) of the Static-99R were consistent with the literature and provided support for the potential use of the measure with Latinos born in the United States and Puerto Rico. These findings and their implications are discussed as they pertain to the assessment of Latino sex offenders.

  16. Photo-production of (99)Mo/(99m)Tc with electron linear accelerator beam.

    Science.gov (United States)

    Avagyan, R; Avetisyan, A; Kerobyan, I; Dallakyan, R

    2014-09-01

    We report on the development of a relatively new method for the production of (99)Mo/(99m)Tc. The method involves the irradiation of natural molybdenum using high-intensity bremsstrahlung photons from the electron beam of the LUE50 linear electron accelerator located at the Yerevan Physics Institute (YerPhi). The production method has been developed and shown to be successful. The linear electron accelerator at YerPhi was upgraded to allow for significant increases of the beam intensity and spatial density. The LUE50 was also instrumented by a remote control system for ease of operation. We have developed and tested the (99m)Tc extraction from the irradiation of natural MoO3. This paper reports on the optimal conditions of our method of (99)Mo production. We show the success of this method with the production and separation of the first usable amounts of (99m)Tc. Copyright © 2014 Elsevier Inc. All rights reserved.

  17. XRD and 119Sn Moessbauer spectroscopy characterization of SnSe obtained from a simple chemical route

    International Nuclear Information System (INIS)

    Bernardes-Silva, Ana Claudia; Mesquita, A.F.; Moura de Neto, E.; Porto, A.O.; Ardisson, J.D.; Lima, G.M. de; Lameiras, F.S.

    2005-01-01

    Crystalline tin selenide semiconductor was synthesized by a chemical route. Selenium powder reacted with potassium boronhydride, giving a soluble selenium species potassium seleniumhydride. The reaction of potassium seleniumhydride with tin chloride produced crystalline tin selenide, which was characterized by X-ray diffraction, 119 Sn Moessbauer spectroscopy and scanning electronic microscopy. The material was thermally treated, in nitrogen flow, at 300 and 600 deg. C for 2 h and the particle size evolution was studied by X-ray diffraction. The X-ray diffraction and 119 Sn Moessbauer results showed that a mixture of tin oxides and orthorhombic tin selenide was obtained

  18. Centrifugal extraction of highly enriched tin isotopes and increase of specific activity of the radionuclide 119mSn on the gas centrifuge cascade

    International Nuclear Information System (INIS)

    Suvorov, I.A.; Tcheltsov, A.N.; Sosnin, L.Yu.; Sazikin, A.A.; Rudnev, A.I.

    2002-01-01

    This work contains the results of research on centrifugal enrichment of 118 Sn isotope followed by irradiation and, finally, a second centrifugal enrichment to produce high specific activity 119m Sn. Non-steady-state separation methods were used for the effective extraction of the radionuclide 119m Sn from the irradiated target. As a result of this work, radiation sources based on 119m Sn were obtained with a specific activity of 500 mCi/g. This is 100 times greater than the specific activity obtained after irradiation in the reactor alone. In addition, the sources had an previously unattainable radio-purity ratio of 113 Sn/ 119m Sn of approximately 10 -6

  19. 22 CFR 99.3 - [Reserved

    Science.gov (United States)

    2010-04-01

    ... 22 Foreign Relations 1 2010-04-01 2010-04-01 false [Reserved] 99.3 Section 99.3 Foreign Relations DEPARTMENT OF STATE LEGAL AND RELATED SERVICES REPORTING ON CONVENTION AND NON-CONVENTION ADOPTIONS OF EMIGRATING CHILDREN § 99.3 [Reserved] ...

  20. Physical properties of the crust along the seismic refraction profile Vrancea'99

    International Nuclear Information System (INIS)

    Bala, A.; Raileanu, V.; Popa, M.

    2002-01-01

    The seismic refraction project VRANCEA'99 is a contribution to the German-Romanian Collaborative Research Center (CRC) 461: 'Strong Earthquakes - a Challenge for Geosciences and Civil Engineering' which was launched by the University of Karlsruhe, Germany in collaboration with various research institutes in Romania. Preparations started already in 1998, but the actual field work was carried out in May 1999. The seismic project VRANCEA'99, was jointly organized by Geophysical Institute of Karlsruhe University, GeoForschungsZentrum (GFZ) Potsdam, Germany and National Institute for Earth Physics from Bucharest, Romania. Seismic and seismological data recorded on this profile are used to compute a reliable continuous distribution of seismic velocity ( P wave ) with depth. Nine of the explosions from seismic profile Vrancea'99 were also recorded at the seismological telemetered stations from the national seismic network. These explosions were localized as seismic events using seismologic data and also some data from recording sites with 3D sensors deployed along the profile. Time - distance graphs are used to derive the continuous distribution of velocity with depth between 5 km - 45 km depth by Wiechert - Herglotz method. The crustal 2D model from obtained on the profile VRANCEA'99 was introduced as starting model in a density modeling along the refraction profile. The measured values of Bouguer anomaly along the profile were introduced in the model in order to be compared with the computed Bouguer anomaly. After several iterations, the computed Bouguer anomaly is overlapping well enough the observed Bouguer anomaly along the profile. This certify the chosen model (obtained from seismic forward and inverse modeling) using another method of geophysical modeling. Geologic and tectonic implications of the obtained density model are discussed. (authors)

  1. Technetium-99 ({sup 99}Tc) in annual growth segments of knotted wrack (Ascophyllum nodosum)

    Energy Technology Data Exchange (ETDEWEB)

    Heldal, Hilde Elise, E-mail: Hilde.Heldal@imr.no [Institute of Marine Research (IMR), PO Box 1870 Nordnes, N-5817 Bergen (Norway); Sjotun, Kjersti, E-mail: Kjersti.Sjotun@bio.uib.no [University of Bergen (UoB), Department of Biology, PO Box 7803, N-5020 Bergen (Norway)

    2010-10-15

    The distribution of technetium-99 ({sup 99}Tc) in annual growth segments of the brown seaweed Ascophyllum nodosum (Fucales, Phaeophyceae) from the southwestern coast of Norway is examined in samples collected from January to November 2006. A twenty-fold increase in the {sup 99}Tc-concentration from the youngest to the oldest growth segments was found. The concentrations ranged from 42 to 98 Bq/kg dry weight (d.w.) and from 964 to 1000 Bq/kg d.w. in growth segments formed in 2006 and 1996, respectively. In addition, a seasonal variation in the {sup 99}Tc concentration was observed in the actively growing 2006-segments: concentrations decreased from 98 Bq/kg d.w. in April to 54 Bq/kg d.w. in June; there was a further reduction from June to August (42 Bq/kg d.w.); and, finally there was an increase from August to November (93 Bq/kg d.w.). In most of the segments formed between 2000 and 2005, there was a tendency of slightly decreasing {sup 99}Tc-concentrations between June and November but this pattern was not observed for the older growth segments. In order to find an explanation for the non-homogenous distribution of {sup 99}Tc within thalli of A. nodosum, different hypotheses are discussed. Uptake and elimination of {sup 99}Tc appears to be most pronounced in the actively growing segments. To date, such non-homogenous distribution of {sup 99}Tc within thalli of A. nodosum has not been taken into consideration, neither in connection with sample collection nor analysis. This paper shows that special protocols must be followed if A. nodosum is going to be used as a bioindicator for {sup 99}Tc in the marine environment. A sampling strategy is proposed.

  2. Preoperative radiological diagnosis by 99mTc·MIBI-99mTc subtraction scintigraphy for primary hyperparathyroidism

    International Nuclear Information System (INIS)

    Inouye, Takahiro; Tomita, Toshiki; Shinden, Seiichi; Takagi, Hitoshi; Kano, Shigeru.

    1996-01-01

    Preoperative radiological diagnosis constitutes the most important factor for the surgical treatment of hyperparathyroidism. In this regard, MRI is useful for detecting the abnormal parathyroid, but it is often difficult to localize it using MRI only. It is thus necessary to combine this procedure with excellent subtraction scintigraphy. We performed both 201 Tl- 99m Tc and 99m Tc·MIBI- 99m Tc subtraction scintigraphy in seven patients with primary hyperparathyroidism and compared them the radiological results. Five patients presented parathyroid adenomas and the rest hypertrophy of the parathyroid. We could detect the abnormal parathyroid in four patients (57.1%) by 201 Tl- 99m Tc subtraction scintigraphy and in six patients (85.7%) by 99m Tc·MIBI- 99m Tc subtraction scintigraphy. We therefore believe that 99m Tc·MIBI- 99m Tc subtraction scintigraphy will become an essential examination for primary hyperparathyroidism rather than the presently employed 201 Tl- 99m Tc subtraction scintigraphy. (author)

  3. Problems in clinical practice of domestic supply of 99Mo/99mTc. The direction and problem of stable supply chain of 99Mo in Japan

    International Nuclear Information System (INIS)

    Inoue, Tomio

    2013-01-01

    The shortage of supply of 99 Mo caused by trouble of old nuclear reactors in Canada and Europe caused international problem in the field of nuclear medicine, which has not been completely resolved yet. Because all of 99 Mo/ 99m Tc generator in Japan has been imported, Japan Atomic Energy Commission (JAEC) suggested the necessity of establishment of stable supply chain of 99 Mo ( 99 Mo/ 99m Tc generator). According this suggestion, an ad hoc committee appointed to consider the stable supply chain, which consisted of persons concerned with industry, academic society, Japan Isotope Association, Ministry of Education, Culture, Sports, Science, and Technology-Japan (MEXT), Ministry of Health, Labour and Welfare (MHLW), Japan Atomic Energy Agency (JAEA), National Institute of Radiological Science (NIRS) et al., evaluated and compared several ways of production and purification of 99 Mo from the view point of technological maturity, regulation compatibility, economic suitability, and stability for supply. In this review, the summary of the committee report is introduced. For short term strategy, we need to keep the variable import routes for 99 Mo. As a mid-term goal, we need to establish the supply chain inside Japan as a conclusion of the committee report but it seems to be not easy for utility of nuclear reactor after nuclear accident of Fukushima Daiichi Nuclear Power Plant. The development of the method for 99 Mo/ 99m Tc production using accelerator is also expected for the establishment of stable supply chain. (author)

  4. Contracts for field projects and supporting research on enhanced oil recovery. Progress review number 83, quarter ending June 30, 1995

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1996-08-01

    Summaries of 41 research projects on enhanced recovery are presented under the following sections: (1) chemical flooding; (2) gas displacement; (3) thermal recovery; (4) geoscience technology; (5) resource assessment technology; and (6) reservoir classes. Each presentation gives the title of the project, contract number, research facility, contract date, expected completion data, amount of the award, principal investigator, and DOE program manager, and describes the objectives of the project and a summary of the technical progress.

  5. Los Alamos Science: The Human Genome Project. Number 20, 1992

    Science.gov (United States)

    Cooper, N. G.; Shea, N. eds.

    1992-01-01

    This document provides a broad overview of the Human Genome Project, with particular emphasis on work being done at Los Alamos. It tries to emphasize the scientific aspects of the project, compared to the more speculative information presented in the popular press. There is a brief introduction to modern genetics, including a review of classic work. There is a broad overview of the Genome Project, describing what the project is, what are some of its major five-year goals, what are major technological challenges ahead of the project, and what can the field of biology, as well as society expect to see as benefits from this project. Specific results on the efforts directed at mapping chromosomes 16 and 5 are discussed. A brief introduction to DNA libraries is presented, bearing in mind that Los Alamos has housed such libraries for many years prior to the Genome Project. Information on efforts to do applied computational work related to the project are discussed, as well as experimental efforts to do rapid DNA sequencing by means of single-molecule detection using applied spectroscopic methods. The article introduces the Los Alamos staff which are working on the Genome Project, and concludes with brief discussions on ethical, legal, and social implications of this work; a brief glimpse of genetics as it may be practiced in the next century; and a glossary of relevant terms.

  6. Los Alamos Science: The Human Genome Project. Number 20, 1992

    Energy Technology Data Exchange (ETDEWEB)

    Cooper, N G; Shea, N [eds.

    1992-01-01

    This article provides a broad overview of the Human Genome Project, with particular emphasis on work being done at Los Alamos. It tries to emphasize the scientific aspects of the project, compared to the more speculative information presented in the popular press. There is a brief introduction to modern genetics, including a review of classic work. There is a broad overview of the Genome Project, describing what the project is, what are some of its major five-year goals, what are major technological challenges ahead of the project, and what can the field of biology, as well as society expect to see as benefits from this project. Specific results on the efforts directed at mapping chromosomes 16 and 5 are discussed. A brief introduction to DNA libraries is presented, bearing in mind that Los Alamos has housed such libraries for many years prior to the Genome Project. Information on efforts to do applied computational work related to the project are discussed, as well as experimental efforts to do rapid DNA sequencing by means of single-molecule detection using applied spectroscopic methods. The article introduces the Los Alamos staff which are working on the Genome Project, and concludes with brief discussions on ethical, legal, and social implications of this work; a brief glimpse of genetics as it may be practiced in the next century; and a glossary of relevant terms.

  7. BEAUTY'99 Conference Summary

    International Nuclear Information System (INIS)

    Eerola, Paula

    2000-01-01

    Investigations of B hadrons are expected to break new ground in measuring CP-violation effects. This series of BEAUTY conferences, originating from the 1993 conference in Liblice, has contributed significantly in developing ideas of CP-violation measurements using B hadrons and formulating and comparing critically the B-physics experiments. In the '99 conference in Bled we saw the ripening of the field and the first fruit emerging - Tevatron have produced beautiful B-physics results and more are expected to come with the next run, while the B-physics experiments at DESY, SLAC and KEK are starting their operation. The longer-term projects at LHC and Tevatron have taken their shape and detailed prototyping work is going on. Meanwhile, on the phenomenological side, there has been impressive theoretical progress in understanding deeper the 'standard' measurements and proposing new signatures. In this summary, I will highlight the status of the field as presented in the conference, concentrating on signatures, experiments and R and D programmes

  8. 14 CFR 99.12 - [Reserved

    Science.gov (United States)

    2010-01-01

    ... 14 Aeronautics and Space 2 2010-01-01 2010-01-01 false [Reserved] 99.12 Section 99.12 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF TRANSPORTATION (CONTINUED) AIR TRAFFIC AND GENERAL OPERATING RULES SECURITY CONTROL OF AIR TRAFFIC General § 99.12 [Reserved] ...

  9. Isovector pairing effect on the particle-number projection two-proton separation energy

    Energy Technology Data Exchange (ETDEWEB)

    Mokhtari, Djamila; Kerrouchi, Slimane [Laboratoire de Physique Theorique, Faculte de Physique, Algiers (Algeria); Fellah, Mohamed; Allal, Nassima-Hosni [Laboratoire de Physique Theorique, Faculte de Physique, Algiers (Algeria); Centre de Recherche Nucleaire d' Alger, Comena, Algiers (Algeria)

    2009-07-01

    The two-proton separation energy is studied by performing a particle-number projection with and without inclusion of the isovector neutron-proton (np) pairing correlations. It is numerically evaluated for even-even rare-earth nuclei such that the np pairing parameter is non-zero. It is shown that the two-proton separation energy values calculated using the two approaches join, for almost all the considered elements, for the highest values of (N-Z). However, the results including the np pairing correlations are closest to the experimental data when available. Moreover, the two methods lead to the same prediction of the two-proton drip-line position, except for the Dysprosium and the Tungsten.

  10. Managing and sharing the escalating number of sponge "unknowns": the SpongeMaps project.

    Science.gov (United States)

    Hooper, J N A; Hall, K A; Ekins, M; Erpenbeck, D; Wörheide, G; Jolley-Rogers, G

    2013-09-01

    Contemporary collections of sponges in the Indo-west Pacific have escalated substantially due to pharmaceutical discovery, national bioregional planning, and compliance with international conventions on the seabed and its marine genetic resources beyond national jurisdictions. These partially processed operational taxonomic unit (OTU) collections now vastly outweigh the expertise available to make them better "known" via complete taxonomy, yet for many bioregions they represent the most significant body of currently available knowledge. Increasing numbers of cryptic species, previously undetected morphologically, are now being discovered by molecular and chemical analyses. The uncoordinated and fragmented nature of many previous collections, however, means that knowledge and expertise gained from a particular project are often lost to future projects without a biodiversity informatics legacy. Integrating these diverse data (GIS; OTUs; images; molecular, chemical, and other datasets) required a two-way iterative process so far unavailable for sponges with existing biodiversity informatics tools. SpongeMaps arose from the initial need for online collaboration to integrate morphometric data with molecular barcodes, including the Porifera Tree of Life (PorTol) project. It provides interrogation of existing data to better process new collections; capacity to create new OTUs; publication of online pages for individual species, so as to interpret GIS and other data for online biodiversity databases and services; and automatic links to external datasets for taxonomic hierarchy, specimen GIS and mapping, DNA sequence data, chemical structures, and images.

  11. Use of 99mTc-HMPAO-leucocyte scintigraphy coupled to 99mTc-colloid scintigraphy in diagnosing the osteo-articular sepsis

    International Nuclear Information System (INIS)

    Darlas, Y.; Pegoix, M.; Filmont, J.E.; Leclercq, S.; Rosas, M.H.; Agostini, D.; Aubriot, J.H.; Bouvard, G.

    1997-01-01

    The object of this study was the scintigraphic diagnosis of osseous sepsis based on the absence of congruence between leucocytic and colloidal fixations and the evaluation of the effect of coupling between the scintigraphies (sc) with leucocytes (A) and colloids (B) on the diagnosis feasibility index of this technique. Seventy four patients, 97 sc were divided into two groups according to the scintigraphic technique [(A) only]: 35 sc; [(A) and (B)]: 62 sc. [Prosthesis: 48 patients, 68 sc. Osteitis: 26 patients, 29 sc]. The scintigraphies were performed as follows: (A) autologous leucocytes labelled by 250 - 300 MBq of 99m Tc-HMPAO, with planar incidences (15 min), 3 - 4 hours after injection and (B) Labelled nano-colloids labelled by 180 - 200 MBq of 99m Tc, the same incidences, 30 min after injection. The delay between (A) and (B): 48 hours. The final diagnosis of sepsis: bacteriological and histologic criteria after biopsies and/or clinical, biological and radiological evolution. The comparison between the two groups is given in a table in terms of prevalence, sensitivity and specificity, using the χ2 and Fisher tests. In conclusion, the scintigraphy by 99m Tc-HMPAO-leucocyte is a sensitive method (Se ∼ 90%) for the diagnosis of osseous sepsis and coupled to the scintigraphy by 99m Tc-colloids allow obtaining a high specificity (Sp ≥ 90%) by reducing the number of falsely positive diagnoses

  12. Preparation of hypoxic imaging agents 99Tcm-MNLS and 99Tcm-MLS and their biodistribution in mice

    International Nuclear Information System (INIS)

    Zha Zhihao; Wang Jianjun; Zhu Lin

    2009-01-01

    To develop 99 Tc m labeled hypoxic agents,two phosphate-based chelating agents were coupled to metronidazole, 2- (2-methyl-5-nitro-1H-imidazol-1-yl) ethyl dihydrogen phosphate (MNLS) and its analog 2- (2-methyl-1H-imidazol-1-yl) ethyl dihydrogen phosphate (MLS) were synthesized based on the mechanism of prodrug. Labeling yield of these 99 Tc m complexes were more than 90% as proved by TLC. Paper electrophoresis showed that these complexes were neutral. Biodistribution of these complexes in tumor-bearing mice showed that the uptake of 99 Tc m -MNLS (120 min, 2.99 ± 0.25 ID%/g) in tumor was higher than that of 99 Tc m -HL91 (120 min, 0.93 ± 0.13 ID%/g) and 99 Tc m -MLS (120 min, 1.61 ± 0.13 ID%/g), and the uptake ratio of tumor to muscle and tumor to liver of 99 Tc m -MNLS (120 min, 5.90, 1.03) were higher than that of 99 Tc m -HL91 (120 min, 3.59, 0.17) and 99 Tc m -MLS (120 min, 5.40, 0.13). The higher tumor uptake for 99 Tc m -MNLS than 99 Tc m -MLS suggested that nitroimidazole was a key group for tumor accumulation. 99 Tc m -MNLS had higher tumor uptake and lower liver uptake, which had the potential for tumor imaging and was worth of further vestigation. (authors)

  13. 14 CFR 99.41 - General.

    Science.gov (United States)

    2010-01-01

    ... 14 Aeronautics and Space 2 2010-01-01 2010-01-01 false General. 99.41 Section 99.41 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF TRANSPORTATION (CONTINUED) AIR TRAFFIC AND GENERAL OPERATING RULES SECURITY CONTROL OF AIR TRAFFIC Designated Air Defense Identification Zones § 99...

  14. 14 CFR 99.3 - Definitions.

    Science.gov (United States)

    2010-01-01

    ... 14 Aeronautics and Space 2 2010-01-01 2010-01-01 false Definitions. 99.3 Section 99.3 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF TRANSPORTATION (CONTINUED) AIR TRAFFIC AND GENERAL OPERATING RULES SECURITY CONTROL OF AIR TRAFFIC General § 99.3 Definitions. Aeronautical facility...

  15. {sup 119}Sn-NMR investigations on superconducting Ca{sub 3}Ir{sub 4}Sn{sub 13}: Evidence for multigap superconductivity

    Energy Technology Data Exchange (ETDEWEB)

    Sarkar, R., E-mail: rajibsarkarsinp@gmail.com [Institute for Solid State Physics, TU Dresden, D-01069 Dresden (Germany); Brückner, F.; Günther, M. [Institute for Solid State Physics, TU Dresden, D-01069 Dresden (Germany); Wang, Kefeng; Petrovic, C. [Condensed Matter Physics and Materials Science Department, Brookhaven National Laboratory, Upton, NY 11973 (United States); Biswas, P.K.; Luetkens, H.; Morenzoni, E.; Amato, A. [Laboratory for Muon Spin Spectroscopy, Paul Scherrer Institute, CH-5232 Villigen PSI (Switzerland); Klauss, H-H. [Institute for Solid State Physics, TU Dresden, D-01069 Dresden (Germany)

    2015-12-15

    We report bulk superconductivity (SC) in Ca{sub 3}Ir{sub 4}Sn{sub 13} by means of {sup 119}Sn nuclear magnetic resonance (NMR) experiments. Two classical signatures of BCS superconductivity in spin-lattice relaxation rate (1/T{sub 1}), namely the Hebel–Slichter coherence peak just below the T{sub c}, and the exponential decay in the superconducting phase, are evident. The noticeable decrease of {sup 119}Sn Knight shift below T{sub c} indicates spin-singlet superconductivity. The temperature dependence of the spin-lattice relaxation rate {sup 119}(1/T{sub 1}) is convincingly described by the multigap isotropic superconducting gap. NMR experiments do not witness any sign of enhanced spin fluctuations.

  16. Contemporary evolution of resistance at the major insecticide target site gene Ace-1 by mutation and copy number variation in the malaria mosquito Anopheles gambiae.

    Science.gov (United States)

    Weetman, David; Mitchell, Sara N; Wilding, Craig S; Birks, Daniel P; Yawson, Alexander E; Essandoh, John; Mawejje, Henry D; Djogbenou, Luc S; Steen, Keith; Rippon, Emily J; Clarkson, Christopher S; Field, Stuart G; Rigden, Daniel J; Donnelly, Martin J

    2015-06-01

    Functionally constrained genes are ideal insecticide targets because disruption is often fatal, and resistance mutations are typically costly. Synaptic acetylcholinesterase (AChE) is an essential neurotransmission enzyme targeted by insecticides used increasingly in malaria control. In Anopheles and Culex mosquitoes, a glycine-serine substitution at codon 119 of the Ace-1 gene confers both resistance and fitness costs, especially for 119S/S homozygotes. G119S in Anopheles gambiae from Accra (Ghana) is strongly associated with resistance, and, despite expectations of cost, resistant 119S alleles are increasing significantly in frequency. Sequencing of Accra females detected only a single Ace-1 119S haplotype, whereas 119G diversity was high overall but very low at non-synonymous sites, evidence of strong purifying selection driven by functional constraint. Flanking microsatellites showed reduced diversity, elevated linkage disequilibrium and high differentiation of 119S, relative to 119G homozygotes across up to two megabases of the genome. Yet these signals of selection were inconsistent and sometimes weak tens of kilobases from Ace-1. This unexpected finding is attributable to apparently ubiquitous amplification of 119S alleles as part of a large copy number variant (CNV) far exceeding the size of the Ace-1 gene, whereas 119G alleles were unduplicated. Ace-1 CNV was detectable in archived samples collected when the 119S allele was rare in Ghana. Multicopy amplification of resistant alleles has not been observed previously and is likely to underpin the recent increase in 119S frequency. The large CNV compromised localization of the strong selective sweep around Ace-1, emphasizing the need to integrate CNV analysis into genome scans for selection. © 2015 The Authors. Molecular Ecology published by John Wiley & Sons Ltd.

  17. A simple and sensitive separation technique of 99Mo and 99mTc from their equilibrium mixture

    International Nuclear Information System (INIS)

    Swadesh Mandal; Ajoy Mandal

    2014-01-01

    The present work describes a simple and inexpensive separation method of 99 Mo from the equilibrium mixture. The liquid-liquid extraction technique has been employed to separate 99 Mo and 99m Tc using triisooctylamine (TIOA). The 99 Mo and 99m Tc were quantitatively separated out in 2 M TIOA with tripled distilled water; 99m Tc was back extracted from TIOA organic phase to aqueous phase by 0.1 M DTPA. The species information or indirect speciation of molybdenum was also established by the extraction profile of the molybdenum. (author)

  18. The separation of sup(99m)Tc from 99Mo through an aluminium oxide chromatographic columm

    International Nuclear Information System (INIS)

    Imoto, S.T.

    1980-01-01

    The separation of sup(99m)Tc from 99 Mo using the chromatographic method is studied. Alumina is used as adsorbent. The pH values for adsorption of carrier-free 99 Mo on columns filled with ordinary alumina and with that thermically treated at 1000 0 C for five hours, and the separation conditions of sup(99m)Tc using physiologic solution as eluent are determined. The sup(99m)Tc separation yields of both columns are compared and the quality of the products obtained by successive elutions for 10 days is analyzed. (Author) [pt

  19. 45 CFR 99.25 - Evidence.

    Science.gov (United States)

    2010-10-01

    ... 45 Public Welfare 1 2010-10-01 2010-10-01 false Evidence. 99.25 Section 99.25 Public Welfare DEPARTMENT OF HEALTH AND HUMAN SERVICES GENERAL ADMINISTRATION PROCEDURE FOR HEARINGS FOR THE CHILD CARE AND DEVELOPMENT FUND Hearing Procedures § 99.25 Evidence. (a) Testimony. Testimony shall be given orally under...

  20. 22 CFR 99.1 - Definitions.

    Science.gov (United States)

    2010-04-01

    ... 22 Foreign Relations 1 2010-04-01 2010-04-01 false Definitions. 99.1 Section 99.1 Foreign Relations DEPARTMENT OF STATE LEGAL AND RELATED SERVICES REPORTING ON CONVENTION AND NON-CONVENTION ADOPTIONS OF EMIGRATING CHILDREN § 99.1 Definitions. As used in this part, the term: (a) Convention means...

  1. 45 CFR 99.23 - Discovery.

    Science.gov (United States)

    2010-10-01

    ... 45 Public Welfare 1 2010-10-01 2010-10-01 false Discovery. 99.23 Section 99.23 Public Welfare... DEVELOPMENT FUND Hearing Procedures § 99.23 Discovery. The Department, the Lead Agency, and any individuals or groups recognized as parties shall have the right to conduct discovery (including depositions) against...

  2. Relationship between lung-to-heart uptake ratio of technetium-99m-tetrofosmin during exercise myocardial single photon emission computed tomographic imaging and the number of diseased coronary arteries in patients with effort angina pectoris without myocardial infarction

    International Nuclear Information System (INIS)

    Okajima, Toshiya; Ueshima, Kenji; Nishiyama, Osamu; Ogawa, Muneyoshi; Ohuchi, Mami; Saitoh, Masahiko; Hiramori, Katsuhiko

    2004-01-01

    Increased lung uptake of thallium-201 in exercise myocardial perfusion imaging is a reliable marker of multivessel disease in patients with ischemic heart disease. This study investigated whether the lung-to-heart uptake ratio with technetium-99m ( 99m Tc)-tetrofosmin also provides valuable information to detect patients with multivessel disease. Fifty-three consecutive patients (35 men, 18 women, mean age 66±11 years; single-vessel disease: 29, double-vessel disease: 16, triple-vessel disease: 8) with stable effort angina pectoris without prior myocardial infarction and 17 control subjects (12 men, 5 women, mean age 62±9 years) underwent exercise myocardial perfusion imaging with 99m Tc-tetrofosmin and coronary angiography in January 2000 to December 2002. The lung-to-heart uptake ratio was calculated on an anterior projection before reconstruction of the exercise single photon emission computed tomographic images. The mean lung-to-heart uptake ratio was 0.34±0.04, 0.38±0.07, 0.41±0.05, and 0.46±0.09, in patients with normal coronary, single-vessel disease, double-vessel disease, and triple-vessel disease, respectively. Significantly higher lung-to-heart uptake ratio was associated with more diseased vessels (p 99m Tc-tetrofosmin can provide clinically useful information to detect multivessel disease in patients with ischemic heart disease. (author)

  3. {sup 99m}Tc generator preparation using (n, {gamma}){sup 99}Mo produced ex-natural molybdenum

    Energy Technology Data Exchange (ETDEWEB)

    Le, So Van [Nuclear Research Institute, Dalat (Viet Nam)

    2003-03-01

    Theoretical assessment on the chromatographic {sup 99m}Tc generator preparation using (n, {gamma}) {sup 99}Mo produced ex-natural molybdenum was carried out. The relationship between the neutron flux for MoO{sub 3} target activation, Mo-content or Mo adsorption capacity of column packing material, {sup 99m}Tc pertechnetate concentration and/or {sup 99m}Tc radioactivity of eluate was established. The reasonably lower limit of neutron flux of reactor and Molybdenum content of column packing material were found out to estimate the production of portable chromatographic generators available for nuclear medicine application. The concentration of {sup 99m}Tc pertechnetate eluate of low {sup 99m}Tc concentration using the column elution technique was also evaluate theoretically and conducted successfully in practice. Three options of {sup 99m}Tc generator using Titanium-Molybdate, Zirconium-Molybdate and Zirconium Oxide as generator column-packing materials were prepared and successfully put into use in nuclear medicine application. (author)

  4. Performance tests on column materials for {sup 99}Mo-{sup 99m}Tc generator

    Energy Technology Data Exchange (ETDEWEB)

    Sombrito, E Z; Bulos, A D; Tangonan, M C [Chemistry Research Section, Atomic Research Div., Philippine Nuclear Research Inst., Quezon (Philippines)

    1998-10-01

    To meet the need of producing a {sup 99}Mo-{sup 99m}Tc generator, based on low specific activity reactor-produced {sup 99}Mo, different procedures for preparing zirconium molybdate gels were tested. Performance tests were done on molybdate gel columns prepared using the procedures developed by Vietnam and China, and recently, on a polyzirconium compound (PZC) prepared in Japan. The conditions for the batch drying of a large volume of the gel material were studied as well as the conditions in preparing a column to concentrate technetium-99m. The performance of PZC sample as column material for the generator was also evaluated. (author)

  5. Clinical comparison of technetium-99m-EC, technetium-99-m-MAG3 and Iodine-131-OIH in renal disorders

    International Nuclear Information System (INIS)

    Kabasakal, L.; Turoglu, T.; Oensel, C.

    1995-01-01

    Technetium-99m-ethylenedicysteine has recently been developed for renal function studies. The pharmacokinetics of 99m Tc-EC were studied by constant infusion technique and compared with 99m Tc-MAG3 and 131 I-OIH in 11 patients with various renal disorders. After giving a 7.4 MBq 131 I-OIH and 90-110 MBq 99m Tc-EC or 99m Tc-MAG3 bolus, a constant infusion (MBq/ml) 99m Tc--agent and 0.07 MBq/m 131 I-OIH was started. Sixteen blood and five urine samples were obtained over three hr. The renal clearance of 99m Tc-EC was higher than than of 99m Tc-MAG3. The 99m Tc-EC/OIH and 99m Tc-MAG3/OIH ratios were 0.75 ± 0.05 and 0.55 ± 0.10 (p=0.00087), respectively. The distribution volume of 99m Tc-EC was also higher than that of 99m Tc-MAG3 (15722 ± 4644 and 9509 ± 2788 ml/1.73m 2 , respectively; p=0.072). The 99m Tc-EC/OIH and 99m Tc-MAG/OIH distribution volume ratios were 1.03 ± 0.14 and 0.55 ± 0.10, respectively (p = 0.0003). The 60-min excretion values of 99m Tc-EC and 99m Tc-MAG3 were compared to that of OIH. The 99m Tc-EC/OIH and 99m Tc-MAG3/OIH excretion ratios were 0.96 ± 0.06 and 1.07 ± 0.10, respectively (p=0.162). The protein binding of 99m -EC and OIH were found to be 34% ±4 and 66% ±5, respectively (p 99m Tc-EC was negligible (3% ±1.2) in comparison to OIH (27% ±3; p 99m Tc-EC. This agent has good potential for renal function evaluation. 32 refs., 5 tabs

  6. 99mTc-interleukin-2 scintigraphy for the in vivo imaging of vulnerable atherosclerotic plaques

    International Nuclear Information System (INIS)

    Annovazzi, Alessio; D'Alessandria, Calogero; Scopinaro, Francesco; Bonanno, Elena; Spagnoli, Luigi G.; Arca, Marcello; Marcoccia, Antonella; Violi, Francesco; Toma, Giorgio De; Signore, Alberto

    2006-01-01

    Several histopathological studies have demonstrated that vulnerable plaques are enriched in inflammatory cells. The aims of this study were: (1a) to test the ability of 99m Tc-labelled interleukin-2 ( 99m Tc-IL2) to bind to IL2R-positive (IL2R+) cells in carotid plaques and (1b) to correlate the plaque uptake of 99m Tc-IL2, measured in vivo, with the number of IL2R+ cells within the plaque, measured ex vivo by histology (transversal study, TS), and (2) to evaluate changes in 99m Tc-IL2 uptake in plaques, before and after treatment with a statin or a hypocholesterolaemic diet (longitudinal study, LS). Ultrasound scan was performed for plaque characterisation and localisation. Fourteen patients (16 plaques) eligible for endoarterectomy were recruited for the TS and underwent 99m Tc-IL2 scintigraphy before surgery. Nine patients (13 plaques) were recruited for the LS; these patients received atorvastatin or a standard hypocholesterolaemic diet and 99m Tc-IL2 scintigraphy was performed before and after 3 months of treatment. The degree of 99m Tc-IL2 uptake was expressed as the plaque/background (T/B) ratio. In patients from TS, T/B ratios correlated with the percentage of IL2R+ cells at histology (r=0.707; p=0.002) and the number of IL2R+ cells at flow cytometry (r=0.711; p=0.006). No correlations were observed between ultrasound scores and either scintigraphic or histological findings. In patients from the LS, the mean 99m Tc-IL2 uptake decreased in statin-treated patients (1.75±0.50 vs 2.16±0.44; p=0.012), while it was unchanged in the patients on the hypocholesterolaemic diet (2.33±0.45 vs 2.34±0.5). 99m Tc-IL2 accumulates in vulnerable carotid plaques; this accumulation is correlated with the amount of IL2R+ cells and is influenced by lipid-lowering treatment with a statin. (orig.)

  7. Small genomes and large seeds: chromosome numbers, genome size and seed mass in diploid Aesculus species (Sapindaceae)

    Czech Academy of Sciences Publication Activity Database

    Krahulcová, Anna; Trávníček, Pavel; Krahulec, František; Rejmánek, M.

    2017-01-01

    Roč. 119, č. 6 (2017), s. 957-964 ISSN 0305-7364 Institutional support: RVO:67985939 Keywords : Aesculus * chromosome number * genome size * phylogeny * seed mass Subject RIV: EF - Botanics OBOR OECD: Plant sciences, botany Impact factor: 4.041, year: 2016

  8. 21 CFR 99.1 - Scope.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 1 2010-04-01 2010-04-01 false Scope. 99.1 Section 99.1 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES GENERAL DISSEMINATION OF INFORMATION ON UNAPPROVED/NEW USES FOR MARKETED DRUGS, BIOLOGICS, AND DEVICES General Information § 99.1 Scope. (a) This...

  9. 29 CFR 99.100 - Purpose.

    Science.gov (United States)

    2010-07-01

    ... 29 Labor 1 2010-07-01 2010-07-01 true Purpose. 99.100 Section 99.100 Labor Office of the Secretary of Labor AUDITS OF STATES, LOCAL GOVERNMENTS, AND NON-PROFIT ORGANIZATIONS General § 99.100 Purpose. This part sets forth standards for obtaining consistency and uniformity among Federal agencies for the...

  10. Sequential hepatobiliary scintigraphy of the patients with constitutional jaundice, ICG excretory defect disease and hepatocellular carcinoma with 99mTc-PI, 99mTc-HIDA and 99mTc-EHIDA

    International Nuclear Information System (INIS)

    Mitani, Tsuyoshi

    1987-01-01

    Sequential 2 min scintiphotos were obtained with a scintilation camera after intravenous injection of 3 mCi of 99m Tc-HIDA or 99m Tc-PI. Digital matrix images were simultaneously recorded with computer. Sequential samples for the blood clearance of 99m Tc-HIDA or 99m Tc-PI were obtained for 120 min following injection to the patient of constitutional hyperbilirubinemia and ICG excretory defect disease. In Dubin-Johnson syndrome, the hepatic uptake of 99m Tc-HIDA was faster or normal but the excretion was extremely slower than in normal cases. Both hepatic uptake and excretion of 99m Tc-PI were almost normal. In Rotor's disease, hepatic uptake of 99m Tc-HIDA or 99m Tc-PI was very poor, showing almost no hepatic images in all time. In Gilbert's disease and ICG excretory defect disease, hepatic uptake and excretion of 99m Tc-HIDA or 99m Tc-PI were within normal limit. From these results, Dubin-Johnson syndrome, Rotor's disease and Gilbert's disease show the different patterns between hepatic uptake and excretion of 99m Tc-HIDA and 99m Tc-PI hepatobiliary scintigraphy and these patterns contribute to the differential diagnosis of constitutional jaundice. The usefulness of hepatobiliary imaging with 99m Tc-EHIDA in diagnosis of hepatocellular carcinoma was studied in 15 patients with histologically verified HCC. In 15 patients, 3 patients (20 %) showed increased radioactivity with 99m Tc-EHIDA image, where liver scan with 99m Tc-Sn colloid showed filling defect. These results indicate that use of 99m Tc-EHIDA scan and 67 Ga-citrate imaging is useful for positive visualization of HCC. (author)

  11. Preperation and performance of {sup 99}Mo/{sup 99m}Tc chromatographic column generator based on zirconium molybdosilicate

    Energy Technology Data Exchange (ETDEWEB)

    Mostafa, M.; Saber, H.M.; El-Sadek, A.A. [Atomic Energy Authority, Cairo (Egypt). Hot Labs. Center; Nassar, M.Y. [Benha Univ. (Egypt). Chemistry Dept.

    2016-08-01

    Zirconium molybdosilicate (ZrMoSi) gel prepared using {sup 99}Mo radiotracer via peroxo route was used as a base material for {sup 99}Mo/{sup 99m}Tc column generator. The {sup 99m}Tc elution yield and {sup 99}Mo breakthrough in the eluate were studied as a function of the pH-value of gel precipitation, gel drying temperature and Zr: Mo: Si molar ratio. Precipitation pH-value of 2, drying temperature of 100 C and Zr: Mo: Si molar ratio of 0.5: 0.5: 1 were found to be the optimum conditions achieving {sup 99m}Tc elution yield of 82% and {sup 99}Mo breakthrough of 1.0 x 10{sup -3}%. The gel prepared with the optimum conditions was characterized by BET surface area and pore size analyzer, IR spectroscopy, thermal analysis (TGA and DTA), XRD, XRF and FESEM. Technetium-99m eluted from the optimum ZrMoSi {sup 99}Mo/{sup 99m}Tc generator was found to have a high radiochemical purity (98% as {sup 99m}TcO{sub 4}{sup -}) and chemical purity meeting criteria of clinical grade.

  12. Synthesis and irradiation of titanium molybdates used as matrices of the 99 Mo/ 99m Tc generators

    International Nuclear Information System (INIS)

    Diaz V, H.; Monroy G, F.

    2005-01-01

    The 99m Tc is the radioisotope but used in nuclear medicine. Commercially it takes place starting from generators of 99 Mo/ 99m Tc, composed by a chromatography column padded of aluminium oxide of aluminum, where it is deposited the 99 Mo, product of the fission of the 235 U adsorbed and eluted, by means of a saline solution, in form of 99m TcO 4 - . The production of 99 Mo as a result of the fission, imposes radiochemical separations that generate significant quantities of radioactive waste of medium activity, and inflict elaborated radiochemical manipulation. Due to this, its have been carried out intense investigations to substitute the 99 Mo fission product, by chemical compounds that produce 99 Mo via the reaction 98 Mo(n, γ) 99 Mo. Presently work intends the use of gels of titanium molybdates like matrices of these generators. Titanium molybdates were synthesized starting from solutions TiCl 3 and ammonium molybdates and it was studied the effect of the final pH of the gels, the concentration of the Ti +3 and the influence of the laundry of these on the acting of generators. The best efficiencies and chemical purity, radiochemical and radionuclides of the gels like matrices of generators 99 Mo/ 99m Tc were gotten with the washed gel, elaborated with the solution of TiCI 3 0.35M, and to a final pH of 5.9 (Author)

  13. Efficient one-step direct labelling of recombinant antibodies with technetium-99m

    International Nuclear Information System (INIS)

    Liberatore, M.; Neri, D.; Neri, G.; Pini, A.; Lurilli, A.P.; Ponzo, F.; Spampinato, G.; Padula, F.; Pala, A.; Colella, A.C.

    1995-01-01

    High-affinity bacterially expressed antibody fragments can nowadays be cloned from established hybridomas or, more conveniently, isolated directly from antibody libraries displayed on filamentous phage. Such antibodies can be tagged with C-terminal peptide tags containing one cysteine residue, which represents a convenient functionalisation site for a number of applications, including technetium-99m labelling. Here we describe a simple one-step method for 99m Tc labelling of cysteine-tagged recombinant antibodies with more than 50% radionuclide incorporation. The labelled antibodies displayed full retention of immuoreactivity and good stability. (orig.)

  14. Efficient one-step direct labelling of recombinant antibodies with technetium-99m

    Energy Technology Data Exchange (ETDEWEB)

    Liberatore, M. [Dipartimento di Medicina Sperimentale, Sezione di Medicina Nucleare, Policlinico Umberto I, Universita di Roma `La Sapienza` (Italy); Neri, D. [Cambridge Centre for Protein Engineering - MRC Centre (United Kingdom); Neri, G. [Dipartimento di Biologia Molecolare, Universita di Siena (Italy); Pini, A. [Dipartimento di Biologia Molecolare, Universita di Siena (Italy); Lurilli, A.P. [Dipartimento di Medicina Sperimentale, Sezione di Medicina Nucleare, Policlinico Umberto I, Universita di Roma `La Sapienza` (Italy); Ponzo, F. [Dipartimento di Medicina Sperimentale, Sezione di Medicina Nucleare, Policlinico Umberto I, Universita di Roma `La Sapienza` (Italy); Spampinato, G. [Laboratorio di Biochimica degli Ormoni Sessuali, Il Instituto di Clinica Ostetrica e Ginecologica, Universita di Roma `La Sapienza` (Italy); Padula, F. [Laboratorio di Biochimica degli Ormoni Sessuali, Il Instituto di Clinica Ostetrica e Ginecologica, Universita di Roma `La Sapienza` (Italy); Pala, A. [Laboratorio di Biochimica degli Ormoni Sessuali, Il Instituto di Clinica Ostetrica e Ginecologica, Universita di Roma `La Sapienza` (Italy); Colella, A.C. [Dipartimento di Medicina Sperimentale, Sezione di Medicina Nucleare, Policlinico Umberto I, Universita di Roma `La Sapienza` (Italy)

    1995-11-01

    High-affinity bacterially expressed antibody fragments can nowadays be cloned from established hybridomas or, more conveniently, isolated directly from antibody libraries displayed on filamentous phage. Such antibodies can be tagged with C-terminal peptide tags containing one cysteine residue, which represents a convenient functionalisation site for a number of applications, including technetium-99m labelling. Here we describe a simple one-step method for {sup 99m}Tc labelling of cysteine-tagged recombinant antibodies with more than 50% radionuclide incorporation. The labelled antibodies displayed full retention of immuoreactivity and good stability. (orig.)

  15. Actions needed to ensure a reliable supply of 99Mo and 99mTc?

    International Nuclear Information System (INIS)

    Cameron, R.; Peykov, P.

    2014-01-01

    The NEA established the High-level Group on the Security of Supply of Medical Radioisotopes (HLG-MR) to examine the causes of 99 Mo/ 99 mTc supply shortages in 2009. It undertook an economic analysis and determined that lack of economic sustainability in producing reactors was the major cause of the shortages. From that it developed a policy approach, including principles and supporting recommendations to address those causes. Since then it has looked at the way the supply chain has implemented these policy principles through initiating a self-assessment process, which revealed uneven application and lack of adherence to the key principle of full cost recovery. As part of the analysis, the NEA has also reviewed the global 99 Mo/ 99 mTc supply situation periodically, using the most up-to-date data from supply chain participants, to highlight periods of reduced supply and underscore the case for implementing the HLG-MR policy approach in a timely and globally-consistent manner. This current paper presents the preliminary results from an updated 99 Mo supply and demand forecast, focusing on the potentially critical 2015-2020 period, when two major 99 Mo producers (the NRU reactor in Canada and the OSIRIS reactor in France) are scheduled to cease 99 Mo irradiations. It concludes with a review of the effectiveness of the actions taken to date and indicates where further action is needed. (author)

  16. Silica-gel modified with zirconium oxide as a novel 99Mo adsorbent 99mTc generators

    International Nuclear Information System (INIS)

    Salehi, H.; Mollarazi, E.; Abbasi, H.

    2010-01-01

    A new 99 Mo adsorbent has been prepared with modified silica gel with zirconium oxide (SiO 2 /ZrO 2 :Na 2 MoO 4 ) and used in technetium-99m generator. The adsorption behaviors of 99 Mo in the form of molybdate and 99m Tc in the form of pertechnetate on the new adsorbent was investigated showed that the adsorption capacity of molybdate on this generator was considerably higher than the usual generator with alumina column. Coating zirconium oxide on the surface of silica gel resulted in higher 99 Mo adsorption of this compound. 99m Tc is eluted with 0.9% NaCl, and the radionuclidic, radiochemical and chemical purities of the eluate were checked. This generator has a great potential as compared to the traditional alumina generators.

  17. Variation of curve number with storm depth

    Science.gov (United States)

    Banasik, K.; Hejduk, L.

    2012-04-01

    Division. American Society of Civil Engineers, 119(2). pp. 334-345. ACKNOWLEDGMENTS The investigation described in the paper is part of the research project no. N N305 396238 founded by PL-Ministry of Science and Higher Education. The support provided by this organization is gratefully acknowledged.

  18. 29 CFR 99.310 - Financial statements.

    Science.gov (United States)

    2010-07-01

    ... 29 Labor 1 2010-07-01 2010-07-01 true Financial statements. 99.310 Section 99.310 Labor Office of the Secretary of Labor AUDITS OF STATES, LOCAL GOVERNMENTS, AND NON-PROFIT ORGANIZATIONS Auditees § 99... have separate audits in accordance with § 99.500(a) and prepare separate financial statements. (b...

  19. 29 CFR 99.300 - Auditee responsibilities.

    Science.gov (United States)

    2010-07-01

    ... 29 Labor 1 2010-07-01 2010-07-01 true Auditee responsibilities. 99.300 Section 99.300 Labor Office... § 99.300 Auditee responsibilities. The auditee shall: (a) Identify, in its accounts, all Federal awards... the schedule of expenditures of Federal awards in accordance with § 99.310. (e) Ensure that the audits...

  20. 29 CFR 99.200 - Audit requirements.

    Science.gov (United States)

    2010-07-01

    ... 29 Labor 1 2010-07-01 2010-07-01 true Audit requirements. 99.200 Section 99.200 Labor Office of the Secretary of Labor AUDITS OF STATES, LOCAL GOVERNMENTS, AND NON-PROFIT ORGANIZATIONS Audits § 99.... Guidance on determining Federal awards expended is provided in § 99.205. (b) Single audit. Non-Federal...

  1. Progress on the Development of (n,γ)99Mo/99mTc generator, an Alternative of Conventional Generator

    International Nuclear Information System (INIS)

    Lee, Jun Sig; Choi, Seung Rag; Nam, Seong Su; Park, Ul Jae; Son, Kwang Jae; Choi, Kang Hyuk; Choi, Sun Ju

    2010-01-01

    Even though different types of generators have been developed to extract 99m Tc, most of the generators uses 99 Mo from the fission products as the mother radionuclide of 99m Tc. Recently, the crisis of 99 Mo production becomes one of the international issues as 99m Tc is a dominant diagnostic radionuclide. The shortage of 99m Tc has been predicted in the society for more than 10 years. However, actions to prevent such crisis were slow as the initial investment to construct a new research reactor for the production of 99 Mo is high. Currently, it is expected the shortage of 99m Tc will last at least for more than 5 years. As an alternative to minimize such crisis, a new approach is proposed and studied. In this approach, the mother source of 99m Tc comes not from fission products but from the neutron irradiation of molybdenum oxide. Hence, most of the research reactors, which do not have capability to produce fission molybdenum, (n,f) 99 Mo can produce 99 Mo. The key issue in this approach is the uptake capacity of the generator column for (n, γ) 99 Mo, which has extremely low specific activity compared to (n,f) 99 Mo. Currently, the results from the research activities at Korea Atomic Energy Research Institute have shown such approach has enough potential as an alternative of the conventional generator. Hence, the progress of the research is reported in this paper

  2. 45 CFR 99.13 - Place.

    Science.gov (United States)

    2010-10-01

    ... 45 Public Welfare 1 2010-10-01 2010-10-01 false Place. 99.13 Section 99.13 Public Welfare DEPARTMENT OF HEALTH AND HUMAN SERVICES GENERAL ADMINISTRATION PROCEDURE FOR HEARINGS FOR THE CHILD CARE AND DEVELOPMENT FUND Preliminary Matters-Notice and Parties § 99.13 Place. The hearing shall be held in the city...

  3. 29 CFR 99.225 - Sanctions.

    Science.gov (United States)

    2010-07-01

    ... 29 Labor 1 2010-07-01 2010-07-01 true Sanctions. 99.225 Section 99.225 Labor Office of the Secretary of Labor AUDITS OF STATES, LOCAL GOVERNMENTS, AND NON-PROFIT ORGANIZATIONS Audits § 99.225 Sanctions. No audit costs may be charged to Federal awards when audits required by this part have not been...

  4. Current status of research and development of 99Mo/99mTc generator in Korea

    International Nuclear Information System (INIS)

    Park, U.J.; Lee, J.S.; Son, K.J.; Nam, S.S.; Kwak, S.I.; Han, H.S.

    2006-01-01

    To supply 99m Tc in stable and economical manner in Korea, a chromatographic generator has been under development at KAERI since late 1980's. The chromatographic type of technetium generator is preferred in hospital because it is more convenient and less time-restricted for applications. Hence, the demand of 99m Tc in medical applications is keep increasing. In Korea, there are more than 200 gamma cameras including SPECT in hospitals. For these applications, approximately 100 units/week of 99m Tc generators of which annual cost reached 3 million US dollars were required in 2002. Hence, the development of 99m Tc generators and technology of fission 99 Mo processing were started while installing the generator loading facility (GLF) at KAERI. This facility is currently on a trial run for the commercial production of 99m Tc generators and expected to produce more than 200 generators per week in 2004. For the fission 99 Mo production, an annulus U foil target was considered as the LEU target. The designed LEU target is being used for target manufacturing test and accident analysis. The develop gel type 99m Tc generators by using a poly zirconium complex (PZC) and alumina column, KAERI has cooperated with a Japanese company since late 1990's. In 2003, experimental studies for molybdate adsorption capacity and elution characteristics of the PZC samples from three different batches produced by Kaken Co. were carried out. (author)

  5. CENRTC Project number-sign 2F3EOA, OCB A-386, acceptance test procedure

    International Nuclear Information System (INIS)

    Akerson, A.W.

    1995-01-01

    This test procedure provides the steps necessary to verify correct functional operation of controls, annunciators, alarms, protective relays and related systems impacted by CENRTC number-sign 2F3EOA, Microwave Transfer Trip Project, modification work performed under work package 6B-93-00043/M (CENRTC 2F3EOA MWTT OCB A-386 PACKAGE). This procedure separates four tests into separate sections: Energization of A-386 Duplex Panel and Circuits; Local RFL 6750 function tests and start-up; SCADA tests; and A-386 local trip tests

  6. 29 CFR 99.405 - Management decision.

    Science.gov (United States)

    2010-07-01

    ... 29 Labor 1 2010-07-01 2010-07-01 true Management decision. 99.405 Section 99.405 Labor Office of... Agencies and Pass-through Entities § 99.405 Management decision. (a) General. The management decision shall... process available to the auditee. (b) Federal agency. As provided in § 99.400(a)(7), the cognizant agency...

  7. 29 CFR 99.510 - Audit findings.

    Science.gov (United States)

    2010-07-01

    ... 29 Labor 1 2010-07-01 2010-07-01 true Audit findings. 99.510 Section 99.510 Labor Office of the Secretary of Labor AUDITS OF STATES, LOCAL GOVERNMENTS, AND NON-PROFIT ORGANIZATIONS Auditors § 99.510 Audit... schedule of prior audit findings prepared by the auditee in accordance with § 99.315(b) materially...

  8. Infection imaging with 99mTc-biotin in patients with prosthetic hip replacement

    International Nuclear Information System (INIS)

    Villa, G.; Mariani, G.; Augeri, C.; Pipino, F.; Paganelli, G.; Chinol, M.

    2002-01-01

    Full text: Although the incidence of infection in prosthetic hip joint replacements has decreased from about 10-15 % to about 0.5-2 % over the last 20 years, the total number of infections has actually increased because of the large number of patients undergoing the procedure. The most frequent clinical presentation of this complication is functional impairment and pain, with or without fever and other signs and/or symptoms of infection. The main is differentiating true infection from simple loosening with inflammation of the implanted stem. Scintigraphy with radiolabeled autologous leukocytes (WBC) represents the 'gold standard' nuclear medicine procedure for imaging infection. However, this procedure is time-consuming, expensive, and involves some biological hazard. Preliminary data, obtained during validation of the avidin/111In-biotin approach, have suggested some potential of 111ln-biotin per se to accumulate at sites of infection. In this pilot study we explored the potential of 99mTc-biotin as an infection imaging agent in pts with orthopedic infections. N4-lys-biotin was labeled with 1110 MBq. Sixteen pts bearing a total of 20 prosthetic hip replacements were enrolled in the study (9 women and 7 men, mean age 73.2 yrs). Eight pts had previously undergone removal of their hip prosthesis because of infection, while infection was suspected in the remaining 8 pts. Scintigraphy was recorded 20 min, then 1, 4 and 24 hr after the i.v. injection of 99mTc-biotin. Within 48 hrs of the 99mTc-biotin study, all pts also underwent scintigraphy with 99mTc-HMPAO-WBC. Out of the 20 hips evaluated, 15 turned out to be infected while in the remaining 5 cases pain was only caused by bone-prosthetic loosening and/or conditions other than infection. In 12/15 infected sites scintigraphy was concordantly positive with both procedures, 99mTc-biotin yielding higher target-to-nontarget ratios than 99mTc-HMPAO-WBC in 4 cases and similar values in the other cases. Discordant patterns

  9. 29 CFR 99.505 - Audit reporting.

    Science.gov (United States)

    2010-07-01

    ... 29 Labor 1 2010-07-01 2010-07-01 true Audit reporting. 99.505 Section 99.505 Labor Office of the Secretary of Labor AUDITS OF STATES, LOCAL GOVERNMENTS, AND NON-PROFIT ORGANIZATIONS Auditors § 99.505 Audit... is required to report under § 99.510(a); (vii) An identification of major programs; (viii) The dollar...

  10. 29 CFR 99.320 - Report submission.

    Science.gov (United States)

    2010-07-01

    ... 29 Labor 1 2010-07-01 2010-07-01 true Report submission. 99.320 Section 99.320 Labor Office of the Secretary of Labor AUDITS OF STATES, LOCAL GOVERNMENTS, AND NON-PROFIT ORGANIZATIONS Auditees § 99.320... package pursuant to § 99.320(d)(2). (vii) A yes or no statement as to whether the auditee qualified as a...

  11. 29 CFR 99.230 - Audit costs.

    Science.gov (United States)

    2010-07-01

    ... 29 Labor 1 2010-07-01 2010-07-01 true Audit costs. 99.230 Section 99.230 Labor Office of the Secretary of Labor AUDITS OF STATES, LOCAL GOVERNMENTS, AND NON-PROFIT ORGANIZATIONS Audits § 99.230 Audit... years ending after December 31, 2003) and is thereby exempted under § 99.200(d) from having an audit...

  12. Comparative evaluation of different nanostructured metal oxides for preparation of clinically useful 99Mo/99mTc generators

    International Nuclear Information System (INIS)

    Ram, Ramu; Chakravarty, Rubel; Dash, Ashutosh

    2015-01-01

    The potential of nanostructured metal oxides such as nanotitania, nanozirconia, nanoalumina and mesoporous alumina, as new generation sorbent materials for preparation of 99 Mo/ 99m Tc generator has recently been demonstrated. A comparative assessment of such materials is essential for determination of their suitability for preparation of clinically useful generators using (n,γ) 99 Mo. Characteristics which were compared included the sorption capacity, shelf-life of the generator, radioactive concentration and purity of 99m Tc for radiopharmaceutical applications. Mesoporous alumina was identified as the most suitable sorbent for ensuring sustainable production of clinical grade 99 Mo/ 99m Tc generators using low specific activity 99 Mo. (author)

  13. Tc-99m tilmanocept versus Tc-99m sulfur colloid in breast cancer sentinel lymph node identification: Results from a randomized, blinded clinical trial.

    Science.gov (United States)

    Unkart, Jonathan T; Hosseini, Ava; Wallace, Anne M

    2017-12-01

    No prior trials have compared sentinel lymph node (SLN) identification outcomes between Tc-99m tilmanocept (TcTM) and Tc-99m sulfur colloid (TcSC) in breast cancer (BC). We report on the secondary outcomes from a randomized, double-blinded, single surgeon clinical trial comparing post-injection site pain between TcTM and TcSC. Patients were randomized to receive a preoperative single, peritumoral intradermal injection of TcTM or TcSC. The number of total, "hot", and blue nodes detected and removed were compared between groups. Fifty-two (27-TcSC and 25-TcTM) patients were enrolled and underwent definitive surgical treatment. At least one "hot" SLN was detected in all patients. Three (5.8%) patients had a disease positive-SLN. The total number of SLNs removed was 61 (mean 2.26 (standard deviation (SD) 0.90)) in the TcSC group and 54 (mean 2.16 (SD 0.90)) in the TcTM group, P = 0.69. The total number of "hot" nodes in the TcSC group was 1.96 (SD 0.76) compared to 2.04 (SD 0.73) in the TcTM group, P = 0.71. The number of identified SLNs did not differ significantly between TcTM and TcSC. Given that no significant technical advantages exist between the two agents, surgeons should choose a radiopharmaceutical based on cost and side effect profile. © 2017 Wiley Periodicals, Inc.

  14. Accumulation of Tc-99m-MIBI and Tc-99m-tetrofosmin in tumor cells. Uptake and washout studies

    International Nuclear Information System (INIS)

    Rodrigues, M.; Aghajanian, A.A.; Sinzinger, H.; Kalinowska, W.; Zielinski, C.

    2002-01-01

    Aim: To investigate in-vitro the uptake and washout of Tc-99m-MIBI and Tc-99m-tetrofosmin in human breast adenocarcinoma and soft tissue sarcoma cell lines. Methods: The uptake of Tc-99m-MIBI and Tc-99m-tetrofosmin (at 37 0 C, 10, 30 and 60 minutes after incubation with 7.4x10E5 Bq each tracer) was investigated in breast adenocarcinoma MCF-7 and SK-BR-3 cells, synovial sarcoma SW 982 cells and chondrosarcoma SW 1353 cells (concentration of 1x10E6 cells/ml incubation medium). Tracer uptake in cells incubated with ouabain (Na/K-ATPase pump inhibitor; 100 μM and 1mM; 15 and 30 minutes), nigericin (increases mitochondrial potential and disrupts cell membrane potential; 5 and 50 μg/ml; 15 minutes) and carbonyl cyanide m-chlorophenylhydrazone (CCCP) (depolarizes mitochondrial membrane; 10 and 100 μM; 30 minutes) was compared to that in cells without incubation with chemical agents (control cells). The washout (at 37 0 C, 10-60 minutes, 30 and 60 minutes after tracer incubation) of Tc-99m-MIBI and Tc-99m-tetrofosmin was studied in MCF-7 cells, SK-BR-3 cells , SW 1353 cells and fibrosarcoma SW 684 cells. Results: Cellular tracer uptake decreased with ouabain (decrease of Tc-99m-tetrofosmin > Tc-99m-MIBI in SK-BR-3 cells and SW 982 cells) and increased with nigericin (increase of Tc-99m-MIBI > Tc-99m-tetrofosmin in all cells) as compared to the uptake in control cells. With CCCP, decrease of Tc-99m-MIBI uptake in cells preincubated with nigericin was higher than that in cells under basal conditions, whereas a similar decrease of Tc-99m-tetrofosmin uptake in these two group of cells was found. Washout of Tc-99m-MIBI from all cells was lower than that of Tc-99m-tetrofosmin. No significant difference in cell-associated activity of both tracers was found between washout after 30 minutes and that after 60 minutes of incubation, in all cells. Washout of Tc-99m-MIBI from SK-BR-3 cells Tc-99m-tetrofosmin) and Na/K-ATPase pump (Tc-99m-tetrofosmin > Tc-99m-MIBI). Tc-99m-MIBI and

  15. Technetium-99 m generator safety simulation

    International Nuclear Information System (INIS)

    Kang, Sang Koo; Kim, Chong Yeal

    2008-01-01

    Technetium ( 99m Tc) is one of the most widely used radioactive isotopes for diagnosis in the world. In general, 99m Tc is produced inside the so called technetium generator where 99Mo decays to 99m Tc. And the generator is usually made out of lead to shield relatively high energy radiation from 99m Tc and 99 Mo. In this paper, a GEANT4 simulation is carried out to test the safety of the 99m Tc generators, taking domestic and Japanese products with radioactivity of 18.50 GBq (500 mCi) for example. According to the domestic regulation on radiation safety, the dose at 10 cm and 100 cm away from the surface of radiation shielder should not exceed 2 mSv∙h -1 and 0.02 mSv∙h -1 , respectively. The simulated dose turned out about only 10% of the limit, satisfying the domestic regulation

  16. Annual energy outlook 1999, with projections to 2020

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1998-12-01

    The Annual Energy Outlook 1999 (AEO99) presents midterm forecasts of energy supply, demand, and prices through 2020 prepared by the Energy Information Administration (EIA). The projections are based on results from EIA`s National Energy Modeling System (NEMS). The report begins with an Overview summarizing the AEO99 reference case. The next section, Legislation and Regulations, describes the assumptions made with regard to laws that affect energy markets and discusses evolving legislative and regulatory issues. Issues in Focus discusses current energy issues--the economic decline in East Asia, growth in demand for natural gas, vehicle emissions standards, competitive electricity pricing, renewable portfolio standards, and carbon emissions. It is followed by the analysis of energy market trends. The analysis in AEO99 focuses primarily on a reference case and four other cases that assume higher and lower economic growth and higher and lower world oil prices than in the reference case. Forecast tables for these cases are provided in Appendixes A through C. Appendixes D and E present a summary of the reference case forecasts in units of oil equivalence and household energy expenditures. The AEO99 projections are based on Federal, State, and local laws and regulations in effect on July 1, 1998. Pending legislation and sections of existing legislation for which funds have not been appropriated are not reflected in the forecasts. Historical data used for the AEOI99 projections were the most current available as of July 31, 1998, when most 1997 data but only partial 1998 data were available.

  17. Comparison of uptake of 99mTc-MIBI, 99mTc-tetrofosmin and 99mT-Q12 into human breast cancer cell lines

    International Nuclear Information System (INIS)

    Yong, M. de; Bernard, B.F.; Breeman, W.A.P.; Ensing, G.; Benjamins, H.; Bakker, W.H.; Visser, T.J.; Krenning, E.P.

    1996-01-01

    Technetium-99m hexakis-2-methoxyisobutyl-isonitrile (MIBI), 99m Tc-tetrofosmin and 99m Tc-Q12 were all introduced for myocardial imaging but found additional applications as they are taken up by different tumours, enabling imaging of these lesions in patients. The aim of this study was to compare the uptake characteristics of these compounds in vitro in the human adenocarcinoma breast cell lines MCF-7 and ZR-75. It was shown that 99m Tc-MIBI had the highest cellular uptake (15.9%±0.5% dose/mg protein after 60 min in MCF-7, and 14.2%±0.4% dose/mg protein in ZR-75), followed by 99m Tc-tetrofosmin (6.8%±0.6% dose/mg protein in MCF-7, and 8.2%±0.2% dose/mg protein in ZR-75) and 99m TC-Q12 (3.2%±0.1% dose/mg protein in MCF-7, and 3.5%±0.3% dose/mg protein in ZR-75 cells). For all three compounds tenfold differences in specific activity did not influence total cell-associated radioactivity. Uptake of 99m Tc-MIBI and 99m Tc-tetrofosmin was obviously lower at 4 C than at 37 C, whereas 99m Tc-Q12 uptake showed only slight temperature dependence. When uptake was compared in cells grown to different cell densities (1 mg/ml cellular protein versus 0.3 mg/ml), no differences in uptake were detected when uptake was corrected for the amount of cellular protein present in the dishes. Furthermore, for all compounds it was shown that cellular radioactivity decreased rapidly after washing. Apart from the differences in cellular uptake of the three compounds after 60 min, no differences in residual cellular radioactivity after washing were found between the different compounds when expressed as a percentage of their 60-min uptake, suggesting that the efflux process of the radiolabelled compounds was similar. The differences in cell-associated activity after 60 min were thus presumably caused by differences in uptake. (orig./MG)

  18. ISSN 2073-9990 East Cent. Afr. J. surg. (Online) 99

    African Journals Online (AJOL)

    Hp 630 Dual Core

    East and Central African Journal of Surgery. August/September 2016 Volume 21 Number 2. 99. Case of Osteosarcoma Presenting Primarily .... РЖЛГР ЗЖ ГЗЖЛГЦФ РЕСО 31 (1): 18 20, Jan Mar 2010. 2. Mana M, Houda A: Low Grade Central ...

  19. 99mTc by 99Mo produced at the ENEA-FNG facility of 14MeV neutrons.

    Science.gov (United States)

    Capogni, M; Pietropaolo, A; Quintieri, L; Fazio, A; De Felice, P; Pillon, M; Pizzuto, A

    2018-04-01

    A severe supply crisis of 99 Mo, precursor of 99m Tc a diagnostic radionuclide largely used in Nuclear Medicine, occurred in 2008-2009 due to repeated shut-down of the two main (aged) fission reactors. An alternative route for producing 99 Mo by 100 Mo(n,2n) 99 Mo reaction was investigated at ENEA. The experiment, designed according to Monte Carlo simulations performed with the Fluka code, produced 99 Mo by irradiating a natural Molybdenum powdered target with 14MeV neutrons produced at the Frascati Neutron Generator. The 99 Mo specific activity was measured at metrological level by γ-ray spectrometry. Copyright © 2017 Elsevier Ltd. All rights reserved.

  20. Production optimization of {sup 99}Mo/{sup 99m}Tc zirconium molybate gel generators at semi-automatic device: DISIGEG

    Energy Technology Data Exchange (ETDEWEB)

    Monroy-Guzman, F., E-mail: fabiola.monroy@inin.gob.mx [Instituto Nacional de Investigaciones Nucleares, Carretera Mexico-Toluca S/N, La Marquesa, Ocoyoacac, 52750, Estado de Mexico (Mexico); Rivero Gutierrez, T., E-mail: tonatiuh.rivero@inin.gob.mx [Instituto Nacional de Investigaciones Nucleares, Carretera Mexico-Toluca S/N, La Marquesa, Ocoyoacac, 52750, Estado de Mexico (Mexico); Lopez Malpica, I.Z.; Hernandez Cortes, S.; Rojas Nava, P.; Vazquez Maldonado, J.C. [Instituto Nacional de Investigaciones Nucleares, Carretera Mexico-Toluca S/N, La Marquesa, Ocoyoacac, 52750, Estado de Mexico (Mexico); Vazquez, A. [Instituto Mexicano del Petroleo, Eje Central Norte Lazaro Cardenas 152, Col. San Bartolo Atepehuacan, 07730, Mexico D.F. (Mexico)

    2012-01-15

    DISIGEG is a synthesis installation of zirconium {sup 99}Mo-molybdate gels for {sup 99}Mo/{sup 99m}Tc generator production, which has been designed, built and installed at the ININ. The device consists of a synthesis reactor and five systems controlled via keyboard: (1) raw material access, (2) chemical air stirring, (3) gel dried by air and infrared heating, (4) moisture removal and (5) gel extraction. DISIGEG operation is described and dried condition effects of zirconium {sup 99}Mo- molybdate gels on {sup 99}Mo/{sup 99m}Tc generator performance were evaluated as well as some physical-chemical properties of these gels. The results reveal that temperature, time and air flow applied during the drying process directly affects zirconium {sup 99}Mo-molybdate gel generator performance. All gels prepared have a similar chemical structure probably constituted by three-dimensional network, based on zirconium pentagonal bipyramids and molybdenum octahedral. Basic structural variations cause a change in gel porosity and permeability, favouring or inhibiting {sup 99m}TcO{sub 4}{sup -} diffusion into the matrix. The {sup 99m}TcO{sub 4}{sup -} eluates produced by {sup 99}Mo/{sup 99m}Tc zirconium {sup 99}Mo-molybdate gel generators prepared in DISIGEG, air dried at 80 Degree-Sign C for 5 h and using an air flow of 90 mm, satisfied all the Pharmacopoeias regulations: {sup 99m}Tc yield between 70-75%, {sup 99}Mo breakthrough less than 3 Multiplication-Sign 10{sup -3}%, radiochemical purities about 97% sterile and pyrogen-free eluates with a pH of 6. - Highlights: Black-Right-Pointing-Pointer {sup 99}Mo/{sup 99m}Tc generators based on {sup 99}Mo-molybdate gels were synthesized at a semi-automatic device. Black-Right-Pointing-Pointer Generator performances depend on synthesis conditions of the zirconium {sup 99}Mo-molybdate gel. Black-Right-Pointing-Pointer {sup 99m}TcO{sub 4}{sup -} diffusion and yield into generator depends on gel porosity and permeability. Black

  1. A number-projected model with generalized pairing interaction in application to rotating nuclei

    Energy Technology Data Exchange (ETDEWEB)

    Satula, W. [Warsaw Univ. (Poland)]|[Joint Institute for Heavy Ion Research, Oak Ridge, TN (United States)]|[Univ. of Tennessee, Knoxville, TN (United States)]|[Royal Institute of Technology, Stockholm (Sweden); Wyss, R. [Royal Institute of Technology, Stockholm (Sweden)

    1996-12-31

    A cranked mean-field model that takes into account both T=1 and T=0 pairing interactions is presented. The like-particle pairing interaction is described by means of a standard seniority force. The neutron-proton channel includes simultaneously correlations among particles moving in time reversed orbits (T=1) and identical orbits (T=0). The coupling between different pairing channels and nuclear rotation is taken into account selfconsistently. Approximate number-projection is included by means of the Lipkin-Nogami method. The transitions between different pairing phases are discussed as a function of neutron/proton excess, T{sub z}, and rotational frequency, {Dirac_h}{omega}.

  2. Study of the elution {sup 99}Mo-{sup 99m}Tc generators produced at IPEN-CNEN/SP

    Energy Technology Data Exchange (ETDEWEB)

    Lopes, Paula Regina Corain [Pontificia Univ. Catolica de Sao Paulo, SP (Brazil); Instituto de Pesquisas Energeticas e Nucleares IPEN/CNEN-SP, Sao Paulo, SP (Brazil)]. E-mail: corain.lopes@uol.com.br; Osso Junior, Joao Alberto [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil)]. E-mail: jaosso@ipen.br

    2007-07-01

    Over the last years {sup 99m}Tc has become a very important asset in modern nuclear medicine, due to the emission of gamma ray of optimal energy (140 keV) and a suitable half-life (6.04 h). A further attribute of {sup 99m}Tc is its formation from the decay of {sup 99}Mo and the availability from {sup 99}Mo-{sup 99m}Tc generator systems. The most common and practical generator types consist of a chromatographic column packed with aluminium oxide, onto which the highly purified fission product {sup 99}Mo (imported from Canada) is adsorbed in the form of molybdate. {sup 99m}Tc is further eluted with saline solution. The objective of this work is to study the performance and the elution profile of {sup 99m}Tc from high activity generators in order to decrease molybdenum and aluminium concentration. The experiments involved the use of paper filters and Sep Pak columns and also the changing in the time interval between elutions. {sup 99}Mo breakthrough was measured using a dose calibrator and aluminium by UV-Vis spectrophotometry. The best results were achieved using a Sep Pak column containing neutral aluminium oxide. (author)

  3. Quality control and testing of 99 sup (m) Tc-macroaggregated albumin

    International Nuclear Information System (INIS)

    Darte, L.; Persson, B.R.R.

    1975-06-01

    33 sup(m)Tc-labelled macroaggregated albumin particles prepared from a commercial 'kit' have been tested in detail. With the introduction of the method of gel chromatography column scanning it became possible to make fast and simple quantitative measurements of the radiochemical purity. This was found to be the only reliable method for quantitative determination of non-aggregated sup(99m)Tc-labelled albumin. The measuring results of the kit in question have shown a labelling efficiency of about 97-99 %. In addition to a few percent of sup(99m)Tc-pertechnetate less than 0.5 % of disturbing radioactivity was found. The labelling was stable for at least 5-6 h. About 80 % of the particles are in the size-range of 10-80 μm. A rough estimation of the number of particles in the solution resulted in 0.5 x 10 6 per mg of MAA. The dynamic studies of the lung uptake and the elimination of sup(99m)Tc-MAA in man resulted in a biological half-time in the lungs of about 1-2 h. The radiation absorbed dose to the lungs per mCi administrered sup(99m)Tc-MAA was estimated to 0.1 rad. Less than 1 % of the radioactivity was accumulated in liver, spleen or kidneys during the first 25 minutes after injection. (author)

  4. Linear optics and projective measurements alone suffice to create large-photon-number path entanglement

    International Nuclear Information System (INIS)

    Lee, Hwang; Kok, Pieter; Dowling, Jonathan P.; Cerf, Nicolas J.

    2002-01-01

    We propose a method for preparing maximal path entanglement with a definite photon-number N, larger than two, using projective measurements. In contrast with the previously known schemes, our method uses only linear optics. Specifically, we exhibit a way of generating four-photon, path-entangled states of the form vertical bar 4,0>+ vertical bar 0,4>, using only four beam splitters and two detectors. These states are of major interest as a resource for quantum interferometric sensors as well as for optical quantum lithography and quantum holography

  5. The Fission-Based  99Mo Production Process ROMOL-99 and Its Application to PINSTECH Islamabad

    Directory of Open Access Journals (Sweden)

    Rudolf Muenze

    2013-01-01

    Full Text Available An innovative process for fission based 99Mo production has been developed under Isotope Technologies Dresden (ITD GmbH (former Hans Wälischmiller GmbH (HWM, Branch Office Dresden, and its functionality has been tested and proved at the Pakistan Institute of Nuclear Science and Technology (PINSTECH, Islamabad. Targets made from uranium aluminum alloy clad with aluminum were irradiated in the core of Pakistan Research Reactor-1 (PARR-1. In the mean time more than 50 batches of fission molybdenum-99 (99Mo have been produced meeting the international purity/pharmacopoeia specifications using this ROMOL-99 process. The process is based on alkaline dissolution of the neutron irradiated targets in presence of NaNO3, chemically extracting the 99Mo from various fission products and purifying the product by column chromatography. This ROMOL-99 process will be described in some detail.

  6. Discordant results in Tc-99m tetrofosmin and Tc-99m sestamibi parathyroid scintigraphies; Resultados discordantes em cintilografias das paratireoides realizadas com tetrofosmin-99mTc e com sestamibi-99mTc

    Energy Technology Data Exchange (ETDEWEB)

    Duarte, Paulo Schiavom; Domingues, Fernanda C.; Santi Costa, Michele; Brandao, Cynthia; Oliveira, Marco A.C. de; Vieira, Jose G.H. [Fleury - Centro de Medicina Diagnostica, Sao Paulo, SP (Brazil)]. E-mail: paulo.duarte@fleury.com.br

    2007-10-15

    Parathyroid scintigraphies have been used to detect pathological parathyroid glands either before as well as after the parathyroid resection surgery in patients with hyperparathyroidism. One of the most utilized techniques to perform the studies is the double-phase images with Tc-99m sestamibi, which has been shown to be very accurate in the localization of enlarged parathyroid glands. Similar to Tc-99m sestamibi, Tc-99m tetrofosmin is a radiopharmaceutical initially developed to perform myocardial perfusion study that has been used to perform parathyroid scintigraphies. Although most of the papers suggest that the overall sensitivities of both radiopharmaceuticals are similar, there are some papers questioning the accuracy of Tc-99m tetrofosmin to detect abnormal parathyroid glands. In the present article, we report a case with discordant results by both methods. (author)

  7. Problems in clinical practice of domestic supply of 99Mo/99mTc. Current status and action plans on domestic production of 99Mo raw materials for medical use

    International Nuclear Information System (INIS)

    Nakamura, Yoshihide

    2012-01-01

    NRU in Canada and HFR in the Netherlands which had been producing the most important medical isotope, 99 Mo, were shut down in 2009-2010. As the production of more than 95% of global 99 Mo supply were performed in only five research reactors in the world including the two reactors mentioned above, these shutdowns resulted in global supply shortage of 99 Mo. Although the medical isotope crisis were alleviated after the two reactors returning to service, all of these five 99 Mo producing reactors are approximately 50 years old. Because the remaining life time of these reactors is not so long, the construction of new reactors or the development of new technologies to produce bulk 99 Mo, such as the neutron activation of 98 Mo in a reactor or charged particle reaction by accelerator, are proposed for the long-term security of supply of 99 Mo. The methods using the molybdenum target lead to much lower specific activity of 99 Mo compared to the production with fission method. The new chemical processing technologies, such as manufacturing 99m Tc-labeled radiopharmaceuticals from such low specific activity 99 Mo, are required for the development of domestic practical production of 99 Mo. (author)

  8. Comparison of carrier-added [99mTc] EDTMP and carrier-free preparations of [99mTc] EDTMP and [99mTc] DPD

    International Nuclear Information System (INIS)

    Krcal, A.; Kletter, K.; Dudczak, R.; Pirich, C.; Mitterhauser, M.

    2002-01-01

    Full text: High uptake of bone-seeking radiopharmaceuticals in malignant bone lesions is a prerequisite for adequate bone scanning. Visual image analysis is impaired due to high soft-tissue activity with currently available [ 99m Tc]-EDTMP-kits. This study aimed to compare carrier-added [ 99m Tc]-EDTMP with carrier-free [ 99m Tc]-EDTMP and [ 99m Tc]-DPD preparations in clinical routine. 15 μg and 150 μg perrhenic acid respectively were added to [ 99m Tc]-pertechnetate (>6 GBq in 3 ml phys. saline). The solution was then transferred into a vial, containing 1 mg of EDTMP, 3.6 mg stannous(II)chloride and 10 mg ascorbic acid under inert conditions. Under vigorous stirring the reaction mixture was heated to 45 o C for 10 min. After cooling down to room temperature the labelling mixture was sterile filtrated (millipore 0.22 μm). Quality control was performed using radio-ITLC (Whatman SG; acetone or ethanol: R f perrhenate/pertechnetate 0.87, colloid/product 0.05; phys. saline: R f colloid 0.00, perrhenate/pertechnetate and product 0.9) allowing rapid and efficient assessment of the product. Carrier free [ 99m Tc]-EDTMP and [ 99m Tc]-DPD were prepared according to instructions of the manufacturer. Clinical studies were performed in 29 patients according to a routine bone scanning protocol by injecting 700-800 MBq of the respective tracer and whole body imaging 3 h thereafter. Radiochemical purity and radiochemical yield relied on various parameters such as concentration of carrier and reducing agent and reaction conditions (pH, reaction time, temperature). Means of the labelling yield were 22 % for the preparation using 150 μg of carrier (5 preparations), 80 % for the preparation using 15 μpg of carrier (10 preparations) and 91 % for the carrier free products (5 preparations). Radiochemical purity was >96 % in all experiments. Colloid was formed in very low amounts, and was completely removed by sterile filtration. In clinical studies quantitative analysis

  9. 99mTc-MAG3: can it be a viable alternative to 99mTc-DTPA ?

    International Nuclear Information System (INIS)

    Bal, C.S.; Padhy, A.K.; Nair, R.; Gopinath, P.G.

    1991-01-01

    The purpose of this study was to assess the potentials of 99m Tc MAG 3 to replace universally used 99m Tc-DTPA as a routine renal agent. Five patients with different nephrological problems were first studied with 99m Tc MAG 3 and then reinvestigated with 99m Tc-DTPA two to seven days later. Renal MAG 3 gamma camera images were found to be almost identical with those of 99m Tc-DTPA images except high hepatic and splenic uptake of the former compound in four out of five patients (80%) irrespective of kidney function. MAG 3 and DTPA renograms showed identical differential renal uptake function (r=0.87) with slightly higher uptake in right kidneys. Time to reach the peak correlated well (r=0.91). Time to reach half maximum renal activity was also found to be almost identical (r=0.97) for MAG 3 and DTPA. It was felt that the age old 99m Tc-DTPA is as good a compound as 99m Tc MAG 3 with regard to imaging and assessment of renal uptake, drainage and differential renal functions. 99m Tc-DTPA is much cheaper, readily available in India and stable to suit the logistics in a busy nuclear medicine department for routine renography. (author). 10 refs., 2 figs., 3 tabs

  10. A study on 99Tcm-citrate and 99Tcm (V)-DMSA imaging in the diagnosis of acute purulent osteoarthritis

    International Nuclear Information System (INIS)

    Wu Zhaozhong; Lin Wei; Wu Hengfu; Wu Changwei; Yuan Gewen; Fan Ziwen; Wu Boyi

    2003-01-01

    Objective: To assess the clinical diagnostic value of 99 Tc m -citrate and 99 Tc m (1/2ae)-dimercaptosuccinic acid (DMSA) imaging in the acute purulent osteoarthritis. Methods: Seventeen patients with confirmed acute purulent osteoarthritis and nineteen patients with non-purulent osteoarthritis were studied. In all patients, 99 Tc m -methylene diphosphonic acid (MDP), 99 Tc m -citrate and 99 Tc m (1/2ae)-DMSA imaging were sequentially performed and the images were analyzed semiquantitatively. Results: In the acute purulent osteoarthritis group, there were positive bonetactic accumulations at certain areas on the three kinds of imaging. In the non-purulent osteoarthritis group, 99 Tc m -MDP and 99 Tc m (1/2ae)-DMSA imaging showed clear bonetactic accumulation, but 99 Tc m -citrate imaging showed only light bonetactic accumulation in addition to the accumulations in soft tissue at certain areas. Lesion to nonlesion ratio (L/N=2.300±0.094) of acute purulent osteoarthritis was greater than that in non-purulent osteoarthritis group (1.298±0.054, P 99 Tc m -citrate imaging, and there was no significant difference between two groups on 99 Tc m (1/2ae)-DMSA imaging (L/N ratio of acute purulent osteoarthritis group was 3.495±0.180, and L/N ratio of non-purulent osteoarthritis group was 3.091±0.091, P>0.05). Conclusions: To diagnose the bone inflammation, 99 Tc m -citrate imaging coalesced with 99 Tc m -MDP or 99 Tc m (1/2ae)-DMSA imaging can help to evaluate the pathologic and physiologic progresses in bone inflammatory areas, at the same time , the information by 99 Tc m -citrate imaging is telling the actual inflammation areas, and that by 99 Tc m (1/2ae)-DMSA and 99 Tc m -MDP imaging is about the response to the increase of bone metabolism

  11. Current Outlook for 99mTc Distribution Based on Electron Accelerator Production

    International Nuclear Information System (INIS)

    Benjamin L. Nelson; W. David Bence; John R. Snyder

    2007-01-01

    In 1999 a practical example illustrating the economical and reliable production of 99mTc from an accelerator was developed. It included the realistic costs involved in establishing and operating the accelerator facility and the distribution of the 99mTc to regions in Florida. However, the technology was never commercialized. Recent political and economic developments prompted this second look at accelerator produced 99mTc. The practicality of this system in 2007 dollars was established to account for inflation and current demand. The same distribution model and production schedule from the Global 1999 study were used. Numbers were found using current rates and costs where possible and indexed estimations when necessary. Though several of the costs increased significantly and the sale price remains at approximately 35 cents/mCi, the unit cost of 99mTc throughput only increased from 12.8 cents/mCi to 15.0 cents/mCi or approximately 17.2% from 1999 to 2007 thus continuing to be economically viable. This study provides ground work for creating business development models at additional locations within the U.S

  12. Magnetism of DyMn{sub 2} and HoMn{sub 2} - {sup 57}Fe and {sup 119}Sn Moessbauer studies

    Energy Technology Data Exchange (ETDEWEB)

    Krop, K. [University of Min. and Metall., Krakow (Poland). Dept. of Solid State Phys.; Zukrowski, J. [University of Min. and Metall., Krakow (Poland). Dept. of Solid State Phys.; Przewoznik, J. [University of Min. and Metall., Krakow (Poland). Dept. of Solid State Phys.; Marzec, J. [University of Min. and Metall., Krakow (Poland). Dept. of Solid State Phys.; Wiesinger, G. [Institute for Experimental Physics, Technical University, Wiedner Hauptstrasse 8-10, A-1040 Vienna (Austria); Haeufler, T. [Institute for Experimental Physics, Technical University, Wiedner Hauptstrasse 8-10, A-1040 Vienna (Austria); Hilscher, G. [Institute for Experimental Physics, Technical University, Wiedner Hauptstrasse 8-10, A-1040 Vienna (Austria); Steiner, W. [Institute for Applied and Technical Physics, Technical University, Wiedner Hauptstrasse 8-10, A-1040 Vienna (Austria)

    1995-05-01

    Moessbauer spectra were measured for two Laves phase compounds DyMn{sub 2} and HoMn{sub 2} in which manganese was substituted to 0.5% with {sup 57}Fe and to 0.2% with {sup 119}Sn. At 4.2 K the {sup 57}Fe and {sup 119}Sn spectra of the Dy compound were unambiguously fitted each with two Zeeman patterns (with relative contributions to the spectra 3:1) corresponding to two different Mn sites - magnetic and nonmagnetic. Transferred hyperfine fields at {sup 119}Sn were found to be proportional to the magnetic moment of Dy and its ferromagnetic component, corroborating the magnetic structure found in neutron diffraction (ND) experiment. The same procedure was carried on with the spectra measured for the Ho compound, but the above mentioned proportionality was not found. ((orig.)).

  13. Combined bone scintigraphy with 99mTc-MDP and 99mTc-ciprofloxacin in differentiation of hip and knee prosthesis aseptic loosening and infection: A preliminary study

    Directory of Open Access Journals (Sweden)

    Pucar Dragan

    2017-01-01

    Full Text Available Background/Aim. Although the number of new primary implantation of hip and knee prostheses every year increases, the rate of failed arthroplasty is nearly the same. The main question is whether it is an aseptic instability or instability caused by infection. The aim of this preliminary study was an attempt with combined 99mTc-ciprofloxacin and 99mTc-methylene diphosphonate (MDP bone scintigraphy to improve diagnostic accuracy in the differentiation of hip and knee prosthesis aseptic loosening and periprosthetic joint infection. Methods. Inclusion criteria of patients for this study were based on suspected periprosthetic joint infection: painful prosthetic joint, restricted joint movements and increased value of erythrocyte sedimentation rate or levels of C-reactive protein. We examined 20 patients with implanted 14 hip and 6 knee prosthesis. All patients also underwent plain radiography of suspected joint. In all patients, three-phase 99mTc-MDP bone scintigraphy was performed. Three to five days after the bone scan, we performed scintigraphy using 99mTc-ciprofloxacin with the calculation of accumulation index. Periprosthetic joint infection was confirmed on the basis of microbiological findings. Results. Periprosthetic joint infection was confirmed in fourteen of twenty observed joints, in five of them the aseptic loosening was present and in one patient’s symptoms were not related to the prosthesis (poor biomechanics of prosthetic joints caused by weaknesses of muscle. Estimated sensitivity/specificity for 99mTc-MDP bone scintigraphy alone were 100/17%; for 99mTc-ciprofloxacin scintigraphy were 85,7/100%. Sensitivity and specificity were 92,3% and 83,3%, respectively for results obtained with combined assessment by both methods. Our study confirmed the high negative predictive value of 99mTc-MDP bone scan. The negative result of bone scan virtually excludes the possibility of periprosthetic infection. On the other hand, positive findings of

  14. Characteristics of minerals in vesicles produced by human osteoblasts hFOB 1.19 and osteosarcoma Saos-2 cells stimulated for mineralization.

    Science.gov (United States)

    Strzelecka-Kiliszek, Agnieszka; Bozycki, Lukasz; Mebarek, Saida; Buchet, Rene; Pikula, Slawomir

    2017-06-01

    Bone cells control initial steps of mineralization by producing extracellular matrix (ECM) proteins and releasing vesicles that trigger apatite nucleation. Using transmission electron microscopy with energy dispersive X-ray microanalysis (TEM-EDX) we compared the quality of minerals in vesicles produced by two distinct human cell lines: fetal osteoblastic hFOB 1.19 and osteosarcoma Saos-2. Both cell lines, subjected to osteogenic medium with ascorbic acid (AA) and β-glycerophosphate (β-GP), undergo the entire osteoblastic differentiation program from proliferation to mineralization, produce the ECM and spontaneously release vesicles. We observed that Saos-2 cells mineralized better than hFOB 1.19, as probed by Alizarin Red-S (AR-S) staining, tissue nonspecific alkaline phosphatase (TNAP) activity and by analyzing the composition of minerals in vesicles. Vesicles released from Saos-2 cells contained and were surrounded by more minerals than vesicles released from hFOB 1.19. In addition, there were more F and Cl substituted apatites in vesicles from hFOB 1.19 than in those from Saos-2 cells as determined by ion ratios. Saos-2 and h-FOB 1.19 cells revealed distinct mineralization profiles, indicating that the process of mineralization may proceed differently in various types of cells. Our findings suggest that TNAP activity is correlated with the relative proportions of mineral-filled vesicles and mineral-surrounded vesicles. The origin of vesicles and their properties predetermine the onset of mineralization at the cellular level. Copyright © 2017 Elsevier Inc. All rights reserved.

  15. Mer tyrosine kinase promotes the survival of t(1;19)-positive acute lymphoblastic leukemia (ALL) in the central nervous system (CNS).

    Science.gov (United States)

    Krause, Sarah; Pfeiffer, Christian; Strube, Susanne; Alsadeq, Ameera; Fedders, Henning; Vokuhl, Christian; Loges, Sonja; Waizenegger, Jonas; Ben-Batalla, Isabel; Cario, Gunnar; Möricke, Anja; Stanulla, Martin; Schrappe, Martin; Schewe, Denis M

    2015-01-29

    Patients with t(1;19)-positive acute lymphoblastic leukemia (ALL) are prone to central nervous system (CNS) relapses, and expression of the TAM (Tyro3, Axl, and Mer) receptor Mer is upregulated in these leukemias. We examined the functional role of Mer in the CNS in preclinical models and performed correlative studies in 64 t(1;19)-positive and 93 control pediatric ALL patients. ALL cells were analyzed in coculture with human glioma cells and normal rat astrocytes: CNS coculture caused quiescence and protection from methotrexate toxicity in Mer(high) ALL cell lines, which was antagonized by short hairpin RNA-mediated knockdown of Mer. Mer expression was upregulated, prosurvival Akt and mitogen-activated protein kinase signaling were activated, and secretion of the Mer ligand Galectin-3 was stimulated. Mer(high) t(1;19) primary cells caused CNS involvement to a larger extent in murine xenografts than in their Mer(low) counterparts. Leukemic cells from Mer(high) xenografts showed enhanced survival in coculture. Treatment of Mer(high) patient cells with the Mer-specific inhibitor UNC-569 in vivo delayed leukemia onset, reduced CNS infiltration, and prolonged survival of mice. Finally, a correlation between high Mer expression and CNS positivity upon initial diagnosis was observed in t(1;19) patients. Our data provide evidence that Mer is associated with survival in the CNS in t(1;19)-positive ALL, suggesting a role as a diagnostic marker and therapeutic target. © 2015 by The American Society of Hematology.

  16. 99mTc-ECD and 99mTc-HM-PAO SPECT in five patients with MELAS

    International Nuclear Information System (INIS)

    Katagiri, Shinako; Nishimaki, Hiroshi; Kitano, Masashi; Horiike, Shigeharu; Kan, Shinichi; Ishii, Katsumi; Matsubayashi, Takashi; Sakai, Fumihiko

    1998-01-01

    Cerebral perfusion was studied in five patients with mitochondrial encephalomyopathy with lactic acidosis and stroke-like episodes syndrome (MELAS), using single photon emission computed tomography (SPECT) with 99m Tc-ethyl cysteinate dimer ( 99m Tc-ECD) or 99m Tc-hexamethyl propyleneamine oxime ( 99m Tc-HM-PAO). In four cases, regional cerebral blood flow (rCBF) was evaluated by the method reported by Mastuda et al. Immediately after the stroke-like episodes, accumulation of the tracer was relatively increased in the temporooccipital lobe, and also increased rCBF was shown in the same area. However, the region showed decreased radioactivity at the chronic stage, and rCBF decreased also. These findings are consistent with positron emission tomography (PET) at the acute stage and autopsy. 99m Tc-ECD SPECT and 99m Tc-HM-PAO SPECT may be useful in the diagnosis and assessment of the progress of the MELAS. (author)

  17. Determination of radionuclidic impurities in 99mTceluate from 99Mo/99mTc generator for quality control

    DEFF Research Database (Denmark)

    Hou, Xiaolin

    2017-01-01

    , 89Sr and 90Sr. Radioactive decay for removal of 99mTc, ion exchange and extraction chromatography for removal of 99Mo and 99Tc are effective for separation of interferences. Gamma spectrometry, LSC with alpha/beta discrimination, and Cherenkov counting using LSC are sensitive methods for measurement...... of the impurity radionuclides. The detection limits of this method are well meet the requirement of the quality control according to the limitation of the pharmacopoeia....

  18. Experimental study of 99Tcm-HL91 and 99Tcm-MIBI in mice bearing Lewis lung cancer

    International Nuclear Information System (INIS)

    Han Chunqi; Li Yaming; Ren Yangang; Yi Lijie

    2000-01-01

    Objective: To evaluate the ability of detecting lung cancer by 99 Tc m -HL91 and 99 Tc m -MIBI in mice bearing Lewis lung cancer. Methods: Four model mice underwent whole body planar imaging at 2 h, 4 h after injection of 99 Tc m -MIBI; four mice underwent whole body planar imaging at 2 h and 4 h after injection of 99 Tc m -HL91, and the mice of the 99 Tc m -HL91 group were then killed, the tumor, blood and organs were removed, weighted and the radioactivity was measured. ROIs were drawn around the tumor, head and chest in whole body planar images, and radioactivity ratios of tumor to head (T/H), chest (T/C) and contralateral limbs (T/L) were calculated. Results: No significant tumor radioactivity in 2 h and 4 h images of 99 Tc m -MIBI mice (T/C: 0.20 +- 0.08 and 0.14 +- 0.07) was found; increased tumor radioactivity was identified in images of 99 Tc m -HL91 mice (T/C: 3.25 +- 1.25 and 2.44 +- 1.07), and there was significant difference (t = 4.8 - 7.5, P 99 Tc m -HL91 in tumor tissue of mice is higher and clearance rate is slower. 99 Tc m -HL91 is a valuable tumor imaging agent for clinical diagnosis for the cancer

  19. Preparation of 99Mo for 99mTc generators and the issue of further development. A survey report

    International Nuclear Information System (INIS)

    Malek, Z.

    1998-01-01

    The following topics are dealt with: World production of Mo-99 for technetium generators; Typical procedures for the preparation of Mo-99; Current and expected decline in the production of Mo-99; and Directions of further development (Water reactors-irradiation systems for the preparation of Mo-99; Homogeneous reactor systems for the preparation of Mo-99 based on molten salts; Systems with accelerators; Thermal processes for the reprocessing of irradiated target material). (P.A.)

  20. Interaction of infectious spleen and kidney necrosis virus ORF119L with PINCH leads to dominant-negative inhibition of integrin-linked kinase and cardiovascular defects in zebrafish.

    Science.gov (United States)

    Yuan, Ji-Min; He, Bai-Liang; Yang, Lu-Yun; Guo, Chang-Jun; Weng, Shao-Ping; Li, Shengwen Calvin; He, Jian-Guo

    2015-01-01

    Infectious spleen and kidney necrosis virus (ISKNV) is the type species of the Megalocytivirus genus, Iridoviridae family, causing a severe systemic disease with high mortality in mandarin fish (Siniperca chuatsi) in China and Southeast Asia. At present, the pathogenesis of ISKNV infection is still not fully understood. Based on a genome-wide bioinformatics analysis of ISKNV-encoded proteins, we found that ISKNV open reading frame 119L (ORF119L) is predicted to encode a three-ankyrin-repeat (3ANK)-domain-containing protein, which shows high similarity to the dominant negative form of integrin-linked kinase (ILK); i.e., viral ORF119L lacks the ILK kinase domain. Thus, we speculated that viral ORF119L might affect the host ILK complex. Here, we demonstrated that viral ORF119L directly interacts with particularly interesting Cys-His-rich protein (PINCH) and affects the host ILK-PINCH interaction in vitro in fathead minnow (FHM) cells. In vivo ORF119L overexpression in zebrafish (Danio rerio) embryos resulted in myocardial dysfunctions with disintegration of the sarcomeric Z disk. Importantly, ORF119L overexpression in zebrafish highly resembles the phenotype of endogenous ILK inhibition, either by overexpressing a dominant negative form of ILK or by injecting an ILK antisense morpholino oligonucleotide. Intriguingly, ISKNV-infected mandarin fish develop disorganized sarcomeric Z disks in cardiomyocytes. Furthermore, phosphorylation of AKT, a downstream effector of ILK, was remarkably decreased in ORF119L-overexpressing zebrafish embryos. With these results, we show that ISKNV ORF119L acts as a domain-negative inhibitor of the host ILK, providing a novel mechanism for the megalocytivirus pathogenesis. Our work is the first to show the role of a dominant negative inhibitor of the host ILK from ISKNV (an iridovirus). Mechanistically, the viral ORF119L directly binds to the host PINCH, attenuates the host PINCH-ILK interaction, and thus impairs ILK signaling. Intriguingly

  1. Synthesis and irradiation of titanium molybdates used as matrices of the {sup 99} Mo/ {sup 99m} Tc generators; Sintesis e irradiacion de molibdatos de titanio utilizados como matrices de los generadores de {sup 99} Mo/ {sup 99m} Tc

    Energy Technology Data Exchange (ETDEWEB)

    Diaz V, H. [Facultad de Quimica, UAEM 50000 Toluca, Estado de Mexico (Mexico); Monroy G, F. [ININ, 52045 Ocoyoacac, Estado de Mexico (Mexico)

    2005-07-01

    The {sup 99m} Tc is the radioisotope but used in nuclear medicine. Commercially it takes place starting from generators of {sup 99} Mo/{sup 99m} Tc, composed by a chromatography column padded of aluminium oxide of aluminum, where it is deposited the {sup 99} Mo, product of the fission of the {sup 235} U adsorbed and eluted, by means of a saline solution, in form of {sup 99m} TcO{sub 4}{sup -}. The production of {sup 99} Mo as a result of the fission, imposes radiochemical separations that generate significant quantities of radioactive waste of medium activity, and inflict elaborated radiochemical manipulation. Due to this, its have been carried out intense investigations to substitute the {sup 99} Mo fission product, by chemical compounds that produce {sup 99} Mo via the reaction {sup 98} Mo(n, {gamma}){sup 99} Mo. Presently work intends the use of gels of titanium molybdates like matrices of these generators. Titanium molybdates were synthesized starting from solutions TiCl{sub 3} and ammonium molybdates and it was studied the effect of the final pH of the gels, the concentration of the Ti{sup +3} and the influence of the laundry of these on the acting of generators. The best efficiencies and chemical purity, radiochemical and radionuclides of the gels like matrices of generators {sup 99} Mo/{sup 99m} Tc were gotten with the washed gel, elaborated with the solution of TiCI{sub 3} 0.35M, and to a final pH of 5.9 (Author)

  2. Radiopharmaceuticals to 99mTc

    International Nuclear Information System (INIS)

    Leon Cabana, Alba

    1994-01-01

    Studies about 99m Tc had demonstrated that have favorable properties for support diagnostic proceedings in nuclear medicine. This physical and chemical properties used for obtain another radiopharmaceuticals have been employed through re actives kits labelled with Tc 99m . A brief description was given about 99m utilities in diagnostic techniques such as endothelium reticular system,renal and hepatic studies,bone scintillators,cardiac diagnostic and cerebral perfusion

  3. Imaging of irradiated liver with Tc-99m-sulfur colloid and Tc-99m-IDA

    International Nuclear Information System (INIS)

    Gelfand, M.J.; Saha, S.; Aron, B.S.

    1981-01-01

    In three cases, irradiated regions of liver failed to concentrate Tc-99m-sulfur colloid. In two of these three, imaging with Tc-99m-acetanilide iminodiacetic acid (IDA) agents within five days showed near normal hepatic uptake of this hepatobiliary imaging agent. The hepatic parenchymal cells may be imaged with Tc-99m-IDA in some irradiated regions of liver, despite loss of reticuloendothelial cell function

  4. Biodistribution of 99Mo in rats

    International Nuclear Information System (INIS)

    Souza, Raphael Sancho Sisley de; Ribeiro, Bianca da Silva; Dantas, Ana Leticia Almeida; Dantas, Bernardo Maranhao; Bernardo Filho, Mario

    2009-01-01

    The modification of 99 Mo standard metabolism in the presence of MDP would alter the dosimetry of this radionuclide in nuclear medicine patients. Therefore, the objective of this work is to evaluate the influence of MDP in the biodistribution of 99 Mo. Wistar rats were divided in two groups of six animals, being inoculated respectively 99 Molibdate and 99 Mo+MDP via plex ocular. The biodistribution study was carried out after 10 and 120 minutes respectively. The organs were counted with a NaI(Tl) detector. The uptake values did not present significant differences among the groups. An in vitro study through planar chromatography was carried out to determine the affinity between molybdenum and MDP. The results show that 99 Mo has low affinity both to propanone and NaCl-0.9% solution. However, 99 Mo in the presence of MDP presented affinity to NaCl-0.9% solution and low affinity to propanone suggesting that 99 Mo was bound to MDP under the conditions of the experiment. (author)

  5. Kinetic study on ligand exchange reaction between ethylenedicysteine and 99mTc- glucoheptonate (99mTc-GH)

    International Nuclear Information System (INIS)

    Wu, C.Y.; Ji, S.R.; Lu, C.X.; Ding, S.Y.; Chen, Z.P.; Lin, X.T.

    2002-01-01

    Aim: 99m Tc-L,L-ethylenedicysteine( 99m Tc-EC)is a new type of renal imaging agent. It can be labeled very easily and efficiently at room temperature through direct labeling at pH 12. The need for direct labeling at pH 12 does not compromise the simplicity and ease of preparation of 99m Tc-EC and its practical usefulness in daily routine. On the basis of the labeling experiments, we developed a ligand exchange labeling method, in which the labeling EC with 99m Tc can be performed at pH 8. In order to provide a theoretic basis, a detailed kinetic study of ligand exchange reaction between 99m Tc- glucoheptonate( 99m Tc-GH) and EC was carried out. Materials and Methods: 99m Tc-EC is prepared as follows: 99m Tc-GH + EC → 99m Tc-EC + GH, labeling can be easily performed by adding 99m TcO 4 - (2∼6ml generator elute) to glucoheptonate solution containing SnCl 2 .2H 2 O solution to form 99m Tc-GH, then freshly prepared 99m Tc-GH is transferred to the aqueous solution of different concentrations of EC at different pH value, after being shaken, 99m Tc-EC was formed. Radiolabeling yield(RLY) and radiochemical purity(RCP) of 99m Tc-GH and 99m Tc-EC were measured by Xinhua No.1 paper with developing system of Me 2 CO/H 2 O/con.NH 3 .H 2 O=9/3/1(V/V). 99m Tc-GH(RCP must be over 98%, 80ul, 3.6∼7.4MBq) was added to 1ml of 0.5mol/L phosphate buffer(pH 12) containing different amount of EC(150, 75, 50 and 15ug), the sample was taken out at different time intervals and RCP was determined. The solution of EC(30ul, 5g/L) was added to 1ml of 0.5mol/L phosphate buffer at different pH value(pH11, 10, 9, 8, 7), after completely vortexed, 99m Tc-GH(RCP must be over 98%, 80ul, 3.6∼7.4MBq) was then added, the sample was taken out and RCP was determined as above. The rate constant(k) of ligand exchange reaction at different concentrations of EC and different reaction pH values were calculated out by integrating. Plot ln[1/(1-RLY)] vs t(time) showed a liner relationship, and the rate

  6. Preparation of Human Serum Albumin Macroaggregated (MAA) labelled with 99mTc via Ligand Exchange

    International Nuclear Information System (INIS)

    El-Mohty, A.A.; El-Ghany, E.A.; Amin, A.A.; El-Koaly, M.T.; Raieh, M.

    2000-01-01

    An alternative method for the preparation of human serum albumin macroaggregated (MAA) labelled with 99m Tc for lung scanning is described. The method is based on the use of stannous methylene diphosphonate (Sn-MDP) as a reducing agent. The may be also increase the number of binding sites in the MAA. The different parameters affecting the labelling yield and in-vitro stability of 99m Tc-MAA have been studied in order to determine the optimum conditions for labelling macroaggregated with 99m Tc. A high labelling yield (98.9%) was achieved and more than 98% of 99m Tc-MAA coated with Sn-MDP. The determined lung uptake in mice was found to be ≥ 90% which better than the reported data. A particular procedure compared to the existing reported procedures, which is recommended for the preparation of Sn-MDP coated MAA labelled with 99m Tc for lung perfusion imaging

  7. Comparative analysis of 99mTc-depreotide and 99mTc-EDDA/HYNIC-TOC thorax scintigrams acquired for the purpose of differential diagnosis of solitary pulmonary nodules

    International Nuclear Information System (INIS)

    Plachcinska, A.; Kusmierek, J.; Mikolajczak, R.; Kozak, J.; Rzeszutek, K.

    2006-01-01

    -EDDA/HYNIC-TOC scintigrams were true negative, 4 - equivocal and 2 false positive. Moreover, 99m Tc-depreotide additionally revealed mediastinal and hilar lesions in 9 patients with benign lesions and 99m Tc-EDDA/HYNIC-TOC - in 8. A visual comparison of scintigrams revealed a higher quality of 99m Tc-Depreotide images in comparison with 99m Tc-EDDA/HYNIC-TOC ones. 99m Tc-Depreotide showed a higher than 99m Tc-EDDA/HYNIC-TOC accumulation in lung tumours compared with blood pool (heart) - 4.5 (s.d. 1.05) and 1.8 (s.d. 0.29), respectively (p 99m Tc-EDDA/HYNIC-TOC scintigrams than on 99m Tc-depreotide ones (16.4% vs. 11.4%; p 99m Tc-depreotide scintigrams probably leads to a lower specificity. Better statistical quality of 99m Tc-depreotide scintigrams facilitates their interpretation and a distinct outline of lungs simplify localization of lesions. A substantial number of false positive lesions in mediastinal and hilar regions in patients without a neoplastic process hamper the usefulness of both radiotracers for effective detection of lung cancer metastases to lymph nodes. (author)

  8. 99mTc generator preparation using (n, γ)99Mo produced using natural molybdenum

    International Nuclear Information System (INIS)

    Kim, Hark Rho; Park, Jin Ho; Lee, Kye Hong

    2003-01-01

    The Mo-99 is a widely used radioisotope in Korea. To fulfill the demand, we are producing Mo-99 using a specially designed and fabricated rig containing MoO 3 target. We are using natural molybdenum so far. But considering the utilization of the enriched molybdenum to increase the specific activity further, we desire the realization of PZC with (n, γ)Mo-99 as early as possible. To make the generator loading facility, we are in progress of construction work for the related hot cell facilities. (author)

  9. Subsides for optimization of transfer of radioactive liquid waste from 99MO production plant to the waste treatment facility

    International Nuclear Information System (INIS)

    Rego, Maria Eugenia de Melo; Vicente, Roberto; Hiromoto, Goro

    2013-01-01

    The increasing need for radioisotopes lead Brazil to consider the domestic production of 99 Mo from fission of low enriched uranium targets. In order to meet the present demand of 99m Tc generators the planned 'end of irradiation' activity of 99 Mo is about 170 TBq per week. The radioactive waste from the production plant will be transferred to a waste treatment facility at the same site. The total activity of the actinides, fission and activation products present in the waste were predicted based on the fission yield and activation data for the irradiation conditions, such as composition and mass of uranium targets, irradiation time, neutron flux, production process and schedule, already established by the project management. The transfer of the waste from the production plant to the treatment facility will be done by means of special shielded packages. In the present study, the commercially available code Scale 6.0 was used to simulate the irradiation of the targets and the decay of radioactive products, assuming that an alkaline dissolution process would be performed on the targets before the removal and purification of 99 Mo. The assessment of the shielding required for the packages containing liquid waste was done using MicroShield 9 code. The results presented here are part of a project that aims at contributing to the design of the waste management system for the 99 Mo production facility. (author)

  10. Accuracy of Dual-Energy Virtual Monochromatic CT Numbers: Comparison between the Single-Source Projection-Based and Dual-Source Image-Based Methods.

    Science.gov (United States)

    Ueguchi, Takashi; Ogihara, Ryota; Yamada, Sachiko

    2018-03-21

    To investigate the accuracy of dual-energy virtual monochromatic computed tomography (CT) numbers obtained by two typical hardware and software implementations: the single-source projection-based method and the dual-source image-based method. A phantom with different tissue equivalent inserts was scanned with both single-source and dual-source scanners. A fast kVp-switching feature was used on the single-source scanner, whereas a tin filter was used on the dual-source scanner. Virtual monochromatic CT images of the phantom at energy levels of 60, 100, and 140 keV were obtained by both projection-based (on the single-source scanner) and image-based (on the dual-source scanner) methods. The accuracy of virtual monochromatic CT numbers for all inserts was assessed by comparing measured values to their corresponding true values. Linear regression analysis was performed to evaluate the dependency of measured CT numbers on tissue attenuation, method, and their interaction. Root mean square values of systematic error over all inserts at 60, 100, and 140 keV were approximately 53, 21, and 29 Hounsfield unit (HU) with the single-source projection-based method, and 46, 7, and 6 HU with the dual-source image-based method, respectively. Linear regression analysis revealed that the interaction between the attenuation and the method had a statistically significant effect on the measured CT numbers at 100 and 140 keV. There were attenuation-, method-, and energy level-dependent systematic errors in the measured virtual monochromatic CT numbers. CT number reproducibility was comparable between the two scanners, and CT numbers had better accuracy with the dual-source image-based method at 100 and 140 keV. Copyright © 2018 The Association of University Radiologists. Published by Elsevier Inc. All rights reserved.

  11. Comparison of biological behavior of 99Tcm-ciprofloxacin (Infecton) and 99Tcm-HIgG in rabbit models of inflammation

    International Nuclear Information System (INIS)

    He Wei; Chen Shaoliang; Mao Jinlei; Jiang Maosong

    2008-01-01

    Objective: 99 Tc m -ciprofloxacin(Infecton) and 99 Tc m -HIgG are both radiopharmaceuticals for inflammation and infectious disease imaging. It was reported that 99 Tc m -ciprofloxacin (Infecton)was able to distinguish inflammation from infection, while 99 Tc m -HIgG was a nonspecific agent. The study was designed to compare the in vivo characteristics between 99 Tc m -ciprofloxacin(Infecton) and 99 Tc m -HIgC in rabbit model of inflammation. Methods: Eight rabbits were grouped as inflammation model (the first group), infection mod- el (the second group), concomitant inflammation and infection model (the third group), and control (the fourth group) groups. A total of 185 MBq (0.5 ml) 99 Tc m -ciprofloxacin (Infecton) was administered intravenously to each rabbit, a serious dynamic images were acquired till 24 h post-injection. Repeated examination with 99 Tc m -HIgG was carried out 2 d later. Results: 99 Tc m -ciprofloxacin (Infecton) scan was negative in the inflammation models and controls, and was positive in the infection models. In the third group 99 Tc m - ciprofloxacin (Infecton) showed infection focus in the left thigh but negative uptake at inflammation focus in the right thigh. 99 Tc m -HIgG scan were positive in all models. The optimal image time for 99 Tc m -ciproftoxacin (Infecton) was 3 h after administration, but positive image could still be observed 24 h later. Conclusion 99 Tc m -ciprofloxacin (Infecton) appears to specifically accumulate in the infective lesion. (authors)

  12. 14 CFR 61.99 - Aeronautical experience.

    Science.gov (United States)

    2010-01-01

    ... 14 Aeronautics and Space 2 2010-01-01 2010-01-01 false Aeronautical experience. 61.99 Section 61.99 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF TRANSPORTATION (CONTINUED) AIRMEN CERTIFICATION: PILOTS, FLIGHT INSTRUCTORS, AND GROUND INSTRUCTORS Recreational Pilots § 61.99...

  13. Direct {sup 99m}Tc labeling of Herceptin (trastuzumab) by {sup 99m}Tc(I) tricarbonyl ion

    Energy Technology Data Exchange (ETDEWEB)

    Chen, W.-J.; Yen, C.-L.; Lo, S.-T.; Chen, K.-T. [Department of Biomedical Engineering and Environmental Sciences, National Tsing Hua University, Hsinchu 30013, Taiwan (China); Lo, J.-M. [Department of Biomedical Engineering and Environmental Sciences, National Tsing Hua University, Hsinchu 30013, Taiwan (China)], E-mail: jmlo@mx.nthu.edu.tw

    2008-03-15

    By simply incubating Herceptin (trastuzumab) with [{sup 99m}Tc(CO){sub 3}(OH{sub 2}){sub 3}]{sup +} ion in saline, a significant yield of {sup 99m}Tc-labeled trastuzumab was found to be achievable. The effective labeling may be based on that trastuzumab is inherent with endogenous histidine group to which {sup 99m}Tc(I) tricarbonyl ion can be strongly bound. For practical {sup 99m}Tc labeling processing, trastuzumab was purified beforehand from the commercial product, Herceptin (Genentech) via size exclusion chromatography to remove the excipient, {alpha}-histidine and a high-labeled yield could be obtained by incubating the purified trastuzumab with [{sup 99m}Tc(CO){sub 3}(OH{sub 2}){sub 3}]{sup +}. Retention of bioactivity of the {sup 99m}Tc(I)-labeled trastuzumab was validated using a cell binding test.

  14. Clinical application of 99mTc-DTPA-HSA

    International Nuclear Information System (INIS)

    Kawamura, Yasuaki; Yamazaki, Junichi; Okuzumi, Ichio

    1989-01-01

    A newly developed blood pool imaging agent, Tc-99m DTPA-HSA (Tc-99m HSA-D), was clinically assessed in blood pool studies of patients with heart disease. Twenty mCi of Tc-99m HSA-D was iv injected to the patients. Similarly, conventional Tc-99m HSA was injected one week later for comparison. Blood counts of Tc-99m HSA-D were significantly higher than those of Tc-99m HSA at 30 minutes after iv injection (p<0.01) and at one, 3, and 6 hours (p<0.001). For the heart, liver, and lungs, sequential counts of Tc-99m HSA-D were also significantly higher than those of Tc-99m HSA. Free Tc-99m uptake in the stomach, thyroid gland, and kidneys was higher on Tc-99m HSA images than Tc-99m HSA-D images. Hepatic and pulmonary uptake of free Tc-99m that were visualized on Tc-99m HSA-D did not influence the diagnostic ability. None of the patients had clinical toxicity of Tc-99m HSA-D. The results indicate that Tc-99m HSA-D is a stable blood pool imaging agent. (Namekawa, K)

  15. Tank 241-U-102, Grab Samples 2U-99-1, 2U-99-2 and 2U-99-3 Analytical Results for the Final Report

    International Nuclear Information System (INIS)

    STEEN, F.H.

    1999-01-01

    This document is the final report for tank 241-U-102 grab samples. Five grab samples were collected from riser 13 on May 26, 1999 and received by the 222-S laboratory on May 26 and May 27, 1999. Samples 2U-99-3 and 2U-99-4 were submitted to the Process Chemistry Laboratory for special studies. Samples 2U-99-1, 2U-99-2 and 2U-99-5 were submitted to the laboratory for analyses. Analyses were performed in accordance with the Compatibility Grab Sampling and Analysis Plan for Fiscal year 1999 (TSAP) (Sasaki, 1999) and the Data Quality Objectives for Tank Farms Waste Compatibility Program (DQO) (Fowler 1995, Mulkey and Miller 1998). The analytical results are presented in the data summary report. None of the subsamples submitted for differential scanning calorimetry (DSC), total organic carbon (TOC) and plutonium 239 (Pu239) analyses exceeded the notification limits as stated in TSAP

  16. Estimates of production and structure of nuclei with Z = 119

    Science.gov (United States)

    Adamian, G. G.; Antonenko, N. V.; Lenske, H.

    2018-02-01

    The comparative analysis of the hot fusion reactions 50Ti +247-249Bk and 51V +246-248Cm for synthesis of element 119 is made with the dinuclear system model and the prediction of nuclear properties of the microscopic-macroscopic approach, where the closed proton shell at Z ≥ 120 is expected. The quasiparticle structures of nuclei in the α-decay chain of 295119 and a possible spread of alpha energies are studied. The calculated values of Qα are compared with available experimental data. The termination of the α-decay chain of 295119 is revealed.

  17. Production and clinical evaluation of 99mTc-octreotide

    International Nuclear Information System (INIS)

    Fettich, J.; Kolenc-Peitl, P.

    2004-01-01

    . Number, size and activity in the lesions were equal for both radiopharmaceuticals. All lesions were seen at 4 as well as 20 hrs. post injection images. Using 111-Inoctreotide some lesions between the kidneys were seen with less confidence on SPECT images as compared with 9m-Tc-octreotide. Lesions inside the liver were also determined more confidently on 99m-Tc-octreotide SPECT reconstructions, due to better count statistics. Octreotide can be labelled as D-Phe1-octreotide with 111-In using DTPA as chelator and as D-Phe1, Tyr3-octreotide with 99m-Tc using ethylendiaminediacetic acid hydrazine- nicotinamide (99m-Tc EDDA/HYNIC-TOC). 111-In-octreotide is commercially available, has long half-life, which allows for repeated imaging up to 72 hrs post injection. Extensive experience with this radiopharmaceutical has been accumulated over several years. However, it has sub optimal energy for imaging, high absorbed dose for the patients, is expensive and is not readily available. Tc-99m octreotide on the other hand profits from nearly ideal imaging characteristics, is inexpensive and always available if produced locally, but allows imaging maximally 24 hrs post injection. Three-dimensional structure of 99m-Tc-octreotide is not exactly the same as of 111-In octreotide. Appropriate low amount of the octreotide can be labelled with high enough 99m-Tc activity to allow good image resolution also using SPECT up to 24 hrs. From our study, it appears that labelling of the peptide is stable not only in vitro but also in vivo. Diagnosis, localization and tumour spread can be determined using 99m-Tc-EDDA/HYNEC-TOC at least as confidently as using 111-In-octreotide. Its advantages are availability, low cost, decreased absorbed dose for the patients and high quality of scintigraphic images. (author)

  18. New way of doppler lifetime measurements used in a case of 119I

    International Nuclear Information System (INIS)

    Pasternak, A.A.; Srebrny, J.; Droste, Ch.; Morek, T.

    2000-01-01

    Complete text of publication follows. An experience gained during data analysis of lifetime measurements (1) in 119 I is presented. The experiment was done using NORDBALL array with plunger inside. The 119 I were produced in the reaction 109 Ag( 13 C,3n) 119 I. Two type of Ag targets were used: thin one (about 0.8 mg/cm 2 ) for RDM measurements and thick one (about 6 mg/cm 2 ) for DSA measurements. Both types of lifetime data were analysed by the same code SHAPE (2) originaly devoted to DSA method. Such sofisticated analysis alowed to determined lifetimes for about 60 levels. The following topics are important for precise lifetime determination: I. Application of DSA software to RDM data. Recoil Distance Doppler Shift Attenuation Method RDDSAM takes into consideration exact γ-lineshape measured using plunger. The information obtained from RDDSAM is more rich than when standard RDM analysis is used. II. Reaction, energy of projectile and statistical side-feeding time. The reaction and the energy of projectile should be chosen to get similar angular momentum distribution of entry states as the one of investigated states. In such case, E2 stretched cascade from entry states to the measured levels is strongly reduced. Then, one can use a simple formula for calculation of the statistical side feeding time: τ sidefeeding = k sf x (E exc - E lev ), where: E exc is the energy of entry state with spin value being the same as spin of investigated level, and E lev is the energy of investigated level. The value of k sf = 0.020(5) ps/MeV was deduced from the analysis of a few fastest transitions in 119 I. III. Self-calibration of stopping power. To perform self calibration of stopping power we propose (1) to use 'semi-thick' target with thickness comparable to recoil range. In our case 0.8 mg/cm 2 target fulfils such condition. For the semi-thick target the observed γ-lineshape is governed by the velocity distribution of recoils leaving target if τ level is much larger than

  19. Biological properties of 99Tcm-HMIBP and its usefulness for bone scintigraphy by comparing with 99Tcm-MDP

    International Nuclear Information System (INIS)

    Luo Shineng; Ye Wanzhong; Xie Minhao; Yu Yanhua; Zhao Yan; Cao Guoxian; Guo Xuehua; Zhou Lian

    2008-01-01

    Objective: Zoledronate has been extensively used for the treatment of tumor-induced hypercalcaemia and osteolytic bone metastases. 1-hydroxy-2-(1-methylimidazol-2-yl) ethylidene-1,1-bisphos- phonic acid (HMIBP) with similar chemical structure as Zoledronate, was therefore considered to be useful as bone imaging agent. In this study the usefulness of 99 Tc m labeled HMIBP for bone imaging was evaluated and the results with the well-established 99 Tc m -methylene diphosphonic acid (MDP) imaging was compared. Methods: Labeled with 99 Tc m , the SnCl 2 ·2H 2 O quantity, radiochemical purity, pH value and stability at 4 degree C of 99 Tc m -HMIBP were measured. Besides, the partition coefficient, plasma protein binding rate, hemodynamic parameters of 99 Tc m -HMIBP and median lethal dose (LD 50 ) of HMIBP were determined. 99 Tc m -HMIBP bone imaging was performed in normal New Zealand rabbits and compared with 99 Tc m -MDP bone imaging. Results: The kit composed of 5 mg HMIBP and 0.05 mg SnCl 2 ·2H 2 O. The labeling rate was 96% after 180 d storage at 4 degree C. The radiochemical purity of 99 Tc m -HMIBP was 98% at pH 5 and the partition coefficients were 0.0125 and 0.0054 at pH 7.0 and 7.4 respectively. The plasma protein binding rate of 99 Tc m -HMIBP was 44.77%. The hemodynamic parameter C valued 3.0979 e -0.0721t +0.1250 e -0.0076t and LD 50 was 8.2 mg/kg. The bone images of 99 Tc m -HMIBP were fairly well 3 h after the injection, which was comparable to 99 Tc m -MDP bone imaging. Conclusions: 99 Tc m -HMIBP had good biological properties and comparable bone imaging quality with 99 Tc m -MDP. It might be a potential agent for both treatment and imaging. (authors)

  20. Comparative study of gated myocardial perfusion imaging using 99Tcm-tetrofosmin and 99Tcm-sestamibi

    International Nuclear Information System (INIS)

    Wang Ruihua; Ruan Qiao; Sun Ke; Han Xingmin; Sun Bingqi; Xie Xinli; Cheng Bing; Chen Yanlin; Liu Baoping

    2013-01-01

    Objective: To compare the results of 99 Tc m -tetrofosmin (TF) and 99 Tc m -MIBI G-MPI in evaluating left ventricular myocardial perfusion and other functional parameters. Methods: TF and MIBI were both labeled by 99 Tc m and the radiochemical purities were tested. During December 2011 to May 2012, 112 patients who had examinations of CAG and echocardiograph in one week after G-MPI were divided into 99 Tc m -TF group (47 patients) and 99 Tc m -MIBI group (65 patients) by simple random sampling. Patients who suffered from severe arrhythmia, clinically suspicious of myocarditis or cardiomyopathy were excluded. The research was approved by the ethics committee, and all patients signed informed consents. One-day 99 Tc m -TF G-MPI and two-day 99 Tc m -MIBI G-MPI were performed. The left ventricular functional parameters were acquired automatically by Cedars quantitative gated SPECT (QGS) software, including LVEF, EDV, ESV, peak filling rate (PFR), peak ejection rate (PER) and phase standard difference (SD). The data were analyzed using χ 2 test, two-sample t test, paired t test and linear correlation analysis by SPSS 17.0. Results: The radiochemical purities of 99 Tc m -TF and 99 Tc m -MIBI were (97.5±0.4) % and (99.1±0.2) % respectively. The coincidence rates of 99 Tc m -TF and 99 Tc m -MIBI G-MPI with CAG were 88.9% (40/45) and 90.5% (57/63), respectively. There was no significant difference between G-MPI results of the two agents (χ 2 =0.389, P>0.05). There was also no significant difference between left ventricular functional parameters of the two agents (LVEF:(62.60±13.56)% vs (60.52±7.08)%, t=0.940; EDV: (103.3±17.29) ml vs (98.52±19.37) ml, t=1.348; ESV: (41.73±12.69) ml vs (46.05±10.81) ml, t=0.851; PER: (2.73±0.67)EDV/s vs (2.61±1.04) EDV/s, t=0.725; PFR: (2.13±0.80) EDV/s vs (2.07±1.09) EDV/s, t=0.339; phase SD: (5.58±4.16)° vs (5.97±4.64)°, t=0.450; all P>0.05). There was no significant difference between left ventricular functional