WorldWideScience

Sample records for project diagnostic performance

  1. Diagnostic framework and health check tool for engineering and technology projects

    Directory of Open Access Journals (Sweden)

    Simon P Philbin

    2014-10-01

    Full Text Available Purpose: Development of a practitioner oriented diagnostic framework and health check tool to support the robust assessment of engineering and technology projects.Design/methodology/approach: The research is based on a literature review that draws together insights on project assessment and critical success factors to establish an integrated systems view of projects. This is extended to allow a comprehensive diagnostic framework to be developed along with a high-level health check tool that can be readily deployed on projects. The utility of the diagnostic framework and health check tool are explored through three illustrative case studies, with two from Canada and one from the United Kingdom. Findings andOriginality/value: The performance of engineering and technology projects can be viewed through a systems perspective and being a function of six sub-systems that are: process, technology, resources, impact, knowledge and culture. The diagnostic framework that is developed through this research integrates these sub-systems to provide a comprehensive assessment methodology for projects, which is linked to existing best practice for project reviews, performance management and maturity models. The case studies provide managerial insights that are related to the diagnostic framework but crucially also position the approach in the context of industrial applications for construction engineering and technology management.Research limitations/implications: The case study approach includes two case studies from the construction and facilities development sector with the third case study from the research and technology sector. Further work is required to investigate the use of the diagnostic framework and health check tool in other sectors.Practical implications: The health check tool will be of practical benefit to new projects managers that require access to a robust and convenient project review methodology for assessing the status and health of a

  2. Development of PETAL diagnostics: PETAPhys project

    Science.gov (United States)

    Raffestin, D.; Boutoux, G.; Baggio, J.; Batani, D.; Blanchot, N.; Bretheau, D.; Hulin, S.; D'Humieres, E.; Granet, F.; Longhi, Th.; Meyer, Ch.; Moreno, Q.; Nuter, R.; Rault, J.; Tikhonchuk, V.; Universite de Bordeaux/Celia Team; CEA. DAM/Cesta Team

    2017-10-01

    Beginning of autumn 2017, PETAL, a Petawatt laser beam, will be operated for experiments on the LMJ facility at the CEA/ Cesta research center. The PETAPhys project provides a support to the qualification phase of the PETAL laser operation. Within the PETAPhys project, we are developing two simple and robust diagnostics permitting both to characterize the focal spot of the PETAL beam and to measure the hard X-ray spectrum at each shot. The first diagnostic consists in optical imaging of the PETAL beam focal spot in the spectral range of the second and third harmonic radiation emitted from the target. The second diagnostic is a hard X-ray dosimeter consisting in a stack of imaging plates (IP) and filters, either placed inside a re-entrant tube or inserted close to target. Numerical simulations as well as experiments on small scale facilities have been performed to design these diagnostics. If available, preliminary results from PETAL experiments will be discussed. We acknowledge the financial support from the French National Research Agency (ANR) in the framework of ``the investments for the future'' Programme IdEx Bordeaux-LAPHIA (ANR-10-IDEX-03-02).

  3. Project management: importance for diagnostic laboratories.

    Science.gov (United States)

    Croxatto, A; Greub, G

    2017-07-01

    The need for diagnostic laboratories to improve both quality and productivity alongside personnel shortages incite laboratory managers to constantly optimize laboratory workflows, organization, and technology. These continuous modifications of the laboratories should be conducted using efficient project and change management approaches to maximize the opportunities for successful completion of the project. This review aims at presenting a general overview of project management with an emphasis on selected critical aspects. Conventional project management tools and models, such as HERMES, described in the literature, associated personal experience, and educational courses on management have been used to illustrate this review. This review presents general guidelines of project management and highlights their importance for microbiology diagnostic laboratories. As an example, some critical aspects of project management will be illustrated with a project of automation, as experienced at the laboratories of bacteriology and hygiene of the University Hospital of Lausanne. It is important to define clearly beforehand the objective of a project, its perimeter, its costs, and its time frame including precise duration estimates of each step. Then, a project management plan including explanations and descriptions on how to manage, execute, and control the project is necessary to continuously monitor the progression of a project to achieve its defined goals. Moreover, a thorough risk analysis with contingency and mitigation measures should be performed at each phase of a project to minimize the impact of project failures. The increasing complexities of modern laboratories mean clinical microbiologists must use several management tools including project and change management to improve the outcome of major projects and activities. Copyright © 2017 The Author(s). Published by Elsevier Ltd.. All rights reserved.

  4. Methodology for quantitative evalution of diagnostic performance. Project III

    International Nuclear Information System (INIS)

    Metz, C.E.

    1985-01-01

    Receiver Operation Characteristic (ROC) methodology is now widely recognized as the most satisfactory approach to the problem of measuring and specifying the performance of a diagnostic procedure. The primary advantage of ROC analysis over alternative methodologies is that it seperates differences in diagnostic accuracy that are due to actual differences in discrimination capacity from those that are due to decision threshold effects. Our effort during the past year has been devoted to developing digital computer programs for fitting ROC curves to diagnostic data by maximum likelihood estimation and to developing meaningful and valid statistical tests for assessing the significance of apparent differences between measured ROC curves. FORTRAN programs previously written here for ROC curve fitting and statistical testing have been refined to make them easier to use and to allow them to be run in a large variety of computer systems. We have attempted also to develop two new curve-fitting programs: one for conventional ROC data that assumes a different functional form for the ROC curve, and one that can be used for ''free-response'' ROC data. Finally, we have cooperated with other investigators to apply our techniques to analyze ROC data generated in clinical studies, and we have sought to familiarize the medical community with the advantages of ROC methodology. 36 ref

  5. Diagnostics Beamline for the SRF Gun Project

    CERN Document Server

    Kamps, T; Goldammer, K; Krämer, Dietrich; Kuske, P; Kuszynski, J; Lipka, D; Marhauser, F; Quast, T; Richter, R

    2005-01-01

    A superconducting rf photo electron injector (SRF gun) is currently under construction by a collaboration between BESSY, DESY, FZR and MBI. The project aims at the design and setup of an CW SRF gun including a diagnostics beamline for the ELBE FEL and to address R&D issues on low emittance injectors for future light sources such as the BESSY FEL. Of critical importance for the injector performance is the control of the electron beam parameters. For this reason a compact diagnostics beamline is under development serving a multitude of operation settings ranging from low-charge (77pC), low-emittance (1 pi mm mrad) mode to high-charge (2.5nC) operation of the gun. For these operation modes beam dynamics simulations are resulting in boundary conditions for the beam instrumentation. Proven and mature technology is projected wherever possible, for example for current and beam position monitoring. The layout of the beam profile and emittance measurement systems is described. For the bunch length, which varies be...

  6. Impacts of dairy diagnostic teams on herd performance.

    Science.gov (United States)

    Weinand, D; Conlin, B J

    2003-05-01

    This study evaluated impacts of educational diagnostic teams of consultants used to transfer technology to dairy farms. Herd management performance changes were measured by comparing Dairy Herd Improvement data from 38 project farms to data from herds that were geographical contemporaries. The value of focused goals for effecting change was also assessed. Interviews provided producers' perception of project outcomes and insight on organization and conduct of dairy diagnostic teams. Changes observed in project herds were small compared with controls with tendencies for increased herd size and improved milk production per cow. Focused goals had greater impacts on increasing herd size, milk per cow, first lactation peak milk, reducing age at first calving, and percentages of cows with subclinical mastitis. Time, money, facility limitations, labor, and alternative priorities were the most cited constraints to implementing changes. Satisfaction scores of producers were significantly related to the degree that team recommendations were followed. Improved attitudes, quality of life, and financial well-being were benefits listed by a majority of producers from participation in the project. If similar projects were to be offered, 83% said they would participate again, and 69% indicated they would pay at least some of the costs. Project farms served as demonstration farms for 1930 other producers in their respective locales, resulting in a multiplier effect of original advice given by consultant teams. Suggestions by farmer participants for improvements in dairy diagnostic teams included needs for at least some unbiased team members, more frequent meetings, more follow-up on recommendations, and consistency of recommendations with family goals.

  7. Development of a computerized system for performance monitoring and diagnostics in nuclear power plants

    International Nuclear Information System (INIS)

    Chou, G.H.; Chao, H.J.

    1995-01-01

    An on-line computerized system for thermal performance monitoring and diagnostics has been developed at the Institute of Nuclear Energy Research (INER). It was the product of the ChinShan plant performance Monitoring, Analysis and Diagnostics Expert System (CS-MADES) project sponsored by Taiwan Power Company (TPC). The system can carry out turbine performance monitoring and analysis during normal operation, and yield diagnostic results of component degradation after finding out the missing generation problems. Three subsystems were generated to support the whole system framework. They are Test Data Processing Subsystem (TDPS), On-line Monitoring and Analysis Subsystem (OMAS), and Thermal Performance Diagnostics Expert System (TPDES). Some visible benefits have been gained so far through the prototype system installed at the Chinshan nuclear power station

  8. Diagnostics for the Rijnhuizen Tokamak Project

    NARCIS (Netherlands)

    Donne, A. J. H.

    1994-01-01

    The research program of the Rijnhuizen Tokamak Project is concentrated on the study of plasma transport processes. The RTP tokamak is therefore equipped with an extensive set of multichannel diagnostics, including a 19-channel FIR interferometer, a 20-channel heterodyne ECE system, an 80-channel

  9. MR cholangiopancreatography: prospective comparison of a breath-hold 2D projection technique with diagnostic ERCP

    International Nuclear Information System (INIS)

    Lomas, D.J.; Bearcroft, P.W.P.; Gimson, A.E.

    1999-01-01

    The aim of this study was to compare prospectively a breath-hold projection magnetic resonance cholangiopancreatography (MRCP) technique with diagnostic endoscopic retrograde cholangiopancreatography (ERCP). Seventy-six patients with suspected strictures or choledocholithiasis were referred for MRCP and subsequent ERCP examination, which were performed within 4 h of each other. The MRCP technique was performed using fat-suppressed rapid acquisition with relaxation enhancement (RARE) projection images obtained in standardised planes with additional targeted projections as required by the supervising radiologist. Two radiologists (in consensus) assessed the MRCP results prospectively and independently for the presence of bile duct calculi, strictures, non-specific biliary dilatation and pancreatic duct dilatation, and recorded a single primary diagnosis. The ERCP was assessed prospectively and independently by a single endoscopist and used as a gold standard for comparison with MRCP. Diagnostic agreement was assessed by the Kappa statistic. The MRCP technique failed in two patients and ERCP in five. In the remaining 69 referrals ERCP demonstrated normal findings in 23 cases, strictures in 19 cases, choledocholithiasis in 9 cases, non-specific biliary dilatation in 14 cases and chronic pancreatitis in 4 cases. The MRCP technique correctly demonstrated 22 of 23 normal cases, 19 strictures with one false positive (sensitivity 100 %, specificity 98 %), all 9 cases of choledocholithiasis with two false positives (sensitivity 100 %, specificity 97 %), 12 of 14 cases of non-specific biliary dilatation and only 1 of 4 cases of chronic pancreatitis. There was overall good agreement for diagnosis based on a kappa value of 0.88. Breath-hold projection MRCP can provide non-invasively comparable diagnostic information to diagnostic ERCP for suspected choledocholithiasis and biliary strictures and may allow more selective use of therapeutic ERCP. (orig.)

  10. Methodology for evaluation of diagnostic performance

    International Nuclear Information System (INIS)

    Metz, C.E.

    1992-01-01

    Effort in this project during the past year has focused on the development, refinement, and distribution of computer software that will allow current Receiver Operating Characteristic (ROC) methodology to be used conveniently and reliably by investigators in a variety of evaluation tasks in diagnostic medicine; and on the development of new ROC methodology that will broaden the spectrum of evaluation tasks and/or experimental settings to which the fundamental approach can be applied. Progress has been limited by the amount of financial support made available to the project

  11. Diagnostic performance of three-dimensional MR maximum intensity projection for the assessment of synovitis of the hand and wrist in rheumatoid arthritis: A pilot study

    Energy Technology Data Exchange (ETDEWEB)

    Li, Xubin, E-mail: lixb@bjmu.edu.cn [Department of Radiology, Tianjin Medical University Cancer Institute and Hospital, National Clinical Reseaech Center for Cancer, Tianjin, Key Laboratory of Cancer Prevention and Therapy, Tianjin 300060 (China); Liu, Xia; Du, Xiangke [Department of Radiology, Peking University People' s Hospital, Beijing 100044 (China); Ye, Zhaoxiang [Department of Radiology, Tianjin Medical University Cancer Institute and Hospital, National Clinical Reseaech Center for Cancer, Tianjin, Key Laboratory of Cancer Prevention and Therapy, Tianjin 300060 (China)

    2014-05-15

    Purpose: To evaluate the diagnostic performance of three-dimensional (3D) MR maximum intensity projection (MIP) in the assessment of synovitis of the hand and wrist in rheumatoid arthritis (RA) compared to 3D contrast-enhanced magnetic resonance imaging (CE-MRI). Materials and methods: Twenty-five patients with RA underwent MR examinations. 3D MR MIP images were derived from the enhanced images. MR images were reviewed by two radiologists for the presence and location of synovitis of the hand and wrist. The diagnostic sensitivity, specificity and accuracy of 3D MIP were, respectively, calculated with the reference standard 3D CE-MRI. Results: In all subjects, 3D MIP images yielded directly and clearly the presence and location of synovitis with just one image. Synovitis demonstrated high signal intensity on MIP images. The k-values for the detection of articular synovitis indicated excellent interobserver agreements using 3D MIP images (k = 0.87) and CE-MR images (k = 0.91), respectively. 3D MIP demonstrated a sensitivity, specificity and accuracy of 91.07%, 98.57% and 96.0%, respectively, for the detection of synonitis. Conclusion: 3D MIP can provide a whole overview of lesion locations and a reliable diagnostic performance in the assessment of articular synovitis of the hand and wrist in patients with RA, which has potential value of clinical practice.

  12. Model Diagnostics for the Department of Energy's Accelerated Climate Modeling for Energy (ACME) Project

    Science.gov (United States)

    Smith, B.

    2015-12-01

    In 2014, eight Department of Energy (DOE) national laboratories, four academic institutions, one company, and the National Centre for Atmospheric Research combined forces in a project called Accelerated Climate Modeling for Energy (ACME) with the goal to speed Earth system model development for climate and energy. Over the planned 10-year span, the project will conduct simulations and modeling on DOE's most powerful high-performance computing systems at Oak Ridge, Argonne, and Lawrence Berkeley Leadership Compute Facilities. A key component of the ACME project is the development of an interactive test bed for the advanced Earth system model. Its execution infrastructure will accelerate model development and testing cycles. The ACME Workflow Group is leading the efforts to automate labor-intensive tasks, provide intelligent support for complex tasks and reduce duplication of effort through collaboration support. As part of this new workflow environment, we have created a diagnostic, metric, and intercomparison Python framework, called UVCMetrics, to aid in the testing-to-production execution of the ACME model. The framework exploits similarities among different diagnostics to compactly support diagnosis of new models. It presently focuses on atmosphere and land but is designed to support ocean and sea ice model components as well. This framework is built on top of the existing open-source software framework known as the Ultrascale Visualization Climate Data Analysis Tools (UV-CDAT). Because of its flexible framework design, scientists and modelers now can generate thousands of possible diagnostic outputs. These diagnostics can compare model runs, compare model vs. observation, or simply verify a model is physically realistic. Additional diagnostics are easily integrated into the framework, and our users have already added several. Diagnostics can be generated, viewed, and manipulated from the UV-CDAT graphical user interface, Python command line scripts and programs

  13. Applying Diagnostics to Enhance Cable System Reliability (Cable Diagnostic Focused Initiative, Phase II)

    Energy Technology Data Exchange (ETDEWEB)

    Hartlein, Rick [Georgia Tech Research Corporation (GTRC), Atlanta, GA (United States). National Electric Energy Testing, Research and Applications Center (NEETRAC); Hampton, Nigel [Georgia Tech Research Corporation (GTRC), Atlanta, GA (United States). National Electric Energy Testing, Research and Applications Center (NEETRAC); Perkel, Josh [Georgia Tech Research Corporation (GTRC), Atlanta, GA (United States). National Electric Energy Testing, Research and Applications Center (NEETRAC); Hernandez, JC [Univ. de Los Andes, Merida (Venezuela); Elledge, Stacy [Georgia Tech Research Corporation (GTRC), Atlanta, GA (United States). National Electric Energy Testing, Research and Applications Center (NEETRAC); del Valle, Yamille [Georgia Tech Research Corporation (GTRC), Atlanta, GA (United States). National Electric Energy Testing, Research and Applications Center (NEETRAC); Grimaldo, Jose [Georgia Inst. of Technology, Atlanta, GA (United States). School of Electrical and Computer Engineering; Deku, Kodzo [Georgia Inst. of Technology, Atlanta, GA (United States). George W. Woodruff School of Mechanical Engineering

    2016-02-01

    The Cable Diagnostic Focused Initiative (CDFI) played a significant and powerful role in clarifying the concerns and understanding the benefits of performing diagnostic tests on underground power cable systems. This project focused on the medium and high voltage cable systems used in utility transmission and distribution (T&D) systems. While many of the analysis techniques and interpretations are applicable to diagnostics and cable systems outside of T&D, areas such as generating stations (nuclear, coal, wind, etc.) and other industrial environments were not the focus. Many large utilities in North America now deploy diagnostics or have changed their diagnostic testing approach as a result of this project. Previous to the CDFI, different diagnostic technology providers individually promoted their approach as the “the best” or “the only” means of detecting cable system defects.

  14. Performance diagnostic system for emergency diesel generators

    International Nuclear Information System (INIS)

    Logan, K.P.

    1991-01-01

    Diesel generators are commonly used for emergency backup power at nuclear stations. Emergency diesel generators (EDGs) are subject to both start-up and operating failures, due to infrequent and fast-start use. EDG reliability can be critical to plant safety, particularly when station blackout occurs. This paper describes an expert diagnostic system designed to consistently evaluate the operating performance of diesel generators. The prototype system is comprised of a suite of sensor monitoring, cylinder combustion analyzing, and diagnostic workstation computers. On-demand assessments of generator and auxiliary equipment performance are provided along with color trend displays comparing measured performance to reference-normal conditions

  15. Implementation of an integrated on-line process surveillance and diagnostic system at the Halden reactor project: MOAS

    International Nuclear Information System (INIS)

    Kim, I.S.; Grini, R.-E.; Nilsen, S.

    2001-01-01

    MOAS is an integrated on-line process surveillance and diagnostic system that uses several different models for knowledge acquisition and diagnostic reasoning, such as goal-tree success-tree model, process monitor trees, and sensor failure diagnosis trees. Within these models, the knowledge of the process and its operation, including deep knowledge, like mass balance or controller algorithm, is incorporated. During an extensive review, made as part of the integrated diagnosis system project of the Halden reactor project, MOAS (Maryland Operator Advisory System) was identified as one of the most thorough systems developed thus far. MOAS encompasses diverse functional aspects that are required for an effective process disturbance management: (1) intelligent process monitoring and alarming, (2) on-line sensor data validation and sensor failure diagnosis, (3) on-line hardware (besides sensors) failure diagnosis, and (4) real-time corrective measure synthesis. The MOAS methodology was used for the NORS (Nokia Research Simulator) process at the Halden man-machine laboratory HAMMLAB of the OECD Halden reactor project. The performance tests of MOAS, implemented in G2 real-time expert system shell, show that MOAS successfully carries out its intended functions, i.e. quickly recognizing an occurring disturbance, correctly diagnosing its cause, and presenting advice on its control to the operator. The lessons learned and insights gained during the implementation and performance tests also are discussed

  16. The diagnostic odds ratio: a single indicator of test performance

    NARCIS (Netherlands)

    Glas, Afina S.; Lijmer, Jeroen G.; Prins, Martin H.; Bonsel, Gouke J.; Bossuyt, Patrick M. M.

    2003-01-01

    Diagnostic testing can be used to discriminate subjects with a target disorder from subjects without it. Several indicators of diagnostic performance have been proposed, such as sensitivity and specificity. Using paired indicators can be a disadvantage in comparing the performance of competing

  17. Diagnostic planning in JT-60 project

    International Nuclear Information System (INIS)

    Matoba, Tohru; Suzuki, Yasuo; Funahashi, Akimasa; Itagaki, Tokiyoshi

    1977-08-01

    The diagnostic plans of JT-60 were made along with design of the main machine. Basic requirements of the diagnostic program are (1) multiple measurement of respective plasma parameters, (2) efficient usage of the discharge, (3) capable data acquisition system, (4) high reliability of the diagnostic equipments, and (5) systematic development of new diagnostic techniques. Dimensions of the diagnostic ports were determined in detailed design of the vacuum vessel, anticipating the possible diagnostic methods. The proposed diagnostic systems and the plans are shown in table and figures respectively. Problems in the diagnostics are also described. (auth.)

  18. The Impact of Gas Turbine Component Leakage Fault on GPA Performance Diagnostics

    Directory of Open Access Journals (Sweden)

    E. L. Ntantis

    2016-01-01

    Full Text Available The leakage analysis is a key factor in determining energy loss from a gas turbine. Once the components assembly fails, air leakage through the opening increases resulting in a performance loss. Therefore, the performance efficiency of the engine cannot be reliably determined, without good estimates and analysis of leakage faults. Consequently, the implementation of a leakage fault within a gas turbine engine model is necessary for any performance diagnostic technique that can expand its diagnostics capabilities for more accurate predictions. This paper explores the impact of gas turbine component leakage fault on GPA (Gas Path Analysis Performance Diagnostics. The analysis is demonstrated with a test case where gas turbine performance simulation and diagnostics code TURBOMATCH is used to build a performance model of a model engine similar to Rolls-Royce Trent 500 turbofan engine, and carry out the diagnostic analysis with the presence of different component fault cases. Conclusively, to improve the reliability of the diagnostic results, a leakage fault analysis of the implemented faults is made. The diagnostic tool used to deal with the analysis of the gas turbine component implemented faults is a model-based method utilizing a non-linear GPA.

  19. Malaria Laboratory Diagnostic Performance: Case studies of two ...

    African Journals Online (AJOL)

    Advantages of rapid diagnostic tests when compared with microscopy are simple to perform, fast, low ... The study was conducted to establish the performance of laboratory diagnosis of malaria in local Malawi .... Government of Malawi.

  20. Magnetic resonance imaging of the wrist: Diagnostic performance statistics

    International Nuclear Information System (INIS)

    Hobby, Jonathan L.; Tom, Brian D.M.; Bearcroft, Philip W.P.; Dixon, Adrian K.

    2001-01-01

    AIM: To review the published diagnostic performance statistics for magnetic resonance imaging (MRI) of the wrist for tears of the triangular fibrocartilage complex, the intrinsic carpal ligaments, and for osteonecrosis of the carpal bones. MATERIALS AND METHODS: We used Medline and Embase to search the English language literature. Studies evaluating the diagnostic performance of MRI of the wrist in living patients with surgical confirmation of MR findings were identified. RESULTS: We identified 11 studies reporting the diagnostic performance of MRI for tears of the triangular fibrocartilage complex for a total of 410 patients, six studies for the scapho-lunate ligament (159 patients), six studies for the luno-triquetral ligament (142 patients) and four studies (56 patients) for osteonecrosis of the carpal bones. CONCLUSIONS: Magnetic resonance imaging is an accurate means of diagnosing tears of the triangular fibrocartilage and carpal osteonecrosis. Although MRI is highly specific for tears of the intrinsic carpal ligaments, its sensitivity is low. The diagnostic performance of MRI in the wrist is improved by using high-resolution T2* weighted 3D gradient echo sequences. Using current imaging techniques without intra-articular contrast medium, magnetic resonance imaging cannot reliably exclude tears of the intrinsic carpal ligaments. Hobby, J.L. (2001)

  1. Project Management Performance Drivers

    OpenAIRE

    Ra’ad, Mohammed A.; Najdawi, Mohammad K.

    2010-01-01

    The practice of project management has gained enormous importance over the past several years in various business industries. “In industries as diverse as pharmaceuticals, software, and aerospace, projects drive business” (Wheatley). This gain of importance can be attributed to the magnitude of the impact project performance results in terms of time, cost, and scope have over the project performing entity. “On the basis of data released by the Bureau of Economic Analysis, part of the US De...

  2. Radiation protection and quality assurance in diagnostic radiology - an IAEA coordinated research project in Asia and Eastern Europe

    Energy Technology Data Exchange (ETDEWEB)

    Oresegun, Modupe [International Atomic Energy Agency, Vienna (Austria); LeHeron, J. [National Radiation Laboratory, Christchurch (New Zealand); Maccia, C. [Centre d' Assurance de qualite des Applications Technologiques dans le Domaine de la Sante, Bourg-la-Reine (France); Padovani, R. [Instituto di Fisica Sanitaria, Udine (Italy); Vano, E. [Medical Physics Group, Radiology Department, Complutense University, Madrid (Spain)

    1999-01-01

    The International Atomic Energy Agency currently has two parallel Coordinated Research Projects (CRP) running in Asia and Eastern Europe. The main objective of the CRPs is to raise the level of awareness in participating countries about the need for radiation protection for patients undergoing diagnostic radiology procedures. This is to be achieved by first assessing the status quo in a sample of hospitals and X-ray rooms in each participating country. A program of optimization of radiation protection for patients is then introduced by means of a comprehensive quality assurance program and the implementation of appropriate dose reduction methods, taking into account clinical requirements for diagnostically acceptable images. Patient dose assessment and image quality assessment are to be performed both before and after the introduction of the quality assurance program. The CRP is divided into two phases - the first is concerned with conventional radiography, while the second involves fluoroscopy and computed tomography. The CRP is still running, restricting the scope of this paper to a discussion of the approach being taken with the project. The project will be completed in 1998, with analysis to follow.

  3. Radiation protection and quality assurance in diagnostic radiology - an IAEA coordinated research project in Asia and Eastern Europe

    International Nuclear Information System (INIS)

    Oresegun, Modupe; LeHeron, J.; Maccia, C.; Padovani, R.; Vano, E.

    1999-01-01

    The International Atomic Energy Agency currently has two parallel Coordinated Research Projects (CRP) running in Asia and Eastern Europe. The main objective of the CRPs is to raise the level of awareness in participating countries about the need for radiation protection for patients undergoing diagnostic radiology procedures. This is to be achieved by first assessing the status quo in a sample of hospitals and X-ray rooms in each participating country. A program of optimization of radiation protection for patients is then introduced by means of a comprehensive quality assurance program and the implementation of appropriate dose reduction methods, taking into account clinical requirements for diagnostically acceptable images. Patient dose assessment and image quality assessment are to be performed both before and after the introduction of the quality assurance program. The CRP is divided into two phases - the first is concerned with conventional radiography, while the second involves fluoroscopy and computed tomography. The CRP is still running, restricting the scope of this paper to a discussion of the approach being taken with the project. The project will be completed in 1998, with analysis to follow

  4. Performance Assessment as a Diagnostic Tool for Science Teachers

    Science.gov (United States)

    Kruit, Patricia; Oostdam, Ron; van den Berg, Ed; Schuitema, Jaap

    2018-04-01

    Information on students' development of science skills is essential for teachers to evaluate and improve their own education, as well as to provide adequate support and feedback to the learning process of individual students. The present study explores and discusses the use of performance assessments as a diagnostic tool for formative assessment to inform teachers and guide instruction of science skills in primary education. Three performance assessments were administered to more than 400 students in grades 5 and 6 of primary education. Students performed small experiments using real materials while following the different steps of the empirical cycle. The mutual relationship between the three performance assessments is examined to provide evidence for the value of performance assessments as useful tools for formative evaluation. Differences in response patterns are discussed, and the diagnostic value of performance assessments is illustrated with examples of individual student performances. Findings show that the performance assessments were difficult for grades 5 and 6 students but that much individual variation exists regarding the different steps of the empirical cycle. Evaluation of scores as well as a more substantive analysis of students' responses provided insight into typical errors that students make. It is concluded that performance assessments can be used as a diagnostic tool for monitoring students' skill performance as well as to support teachers in evaluating and improving their science lessons.

  5. The Influence of Time Pressure and Case Complexity on Physicians׳ Diagnostic Performance

    Directory of Open Access Journals (Sweden)

    Dalal A. ALQahtani

    2016-12-01

    Conclusions: Time pressure did not impact the diagnostic performance, whereas the complexity of the clinical case negatively influenced the diagnostic accuracy. Further studies with the enhanced experimental manipulation of time pressure are needed to reveal the effect of time pressure, if any, on a physician׳s diagnostic performance.

  6. Diagnostic Performance of the Intraoral Radiographs on the Interproximal Dental Caries

    International Nuclear Information System (INIS)

    Kim, Soo Ji; Kang, Byung Cheol

    1998-01-01

    The purpose of this study was to evaluated the diagnostic performance of the senior dental students for the proximal dental caries in intraoral radiographs and to compare it with the dental hospital residents, the reference group. It was also investigated the diagnostic performance according to the carious lesion depth. Thirty-five intraoral periapical and bitewing radiographs with 213 proximal surface included in this study were selected from the dental patients at Chonnam National University Hospital. The observers were 181 senior dental students from 5 dental schools and 40 dentists who were second year resident from 5 dental hospitals. They were asked to evaluate the presence ro the absence of the proximal dental caries. The results were as follows : 1. The mean of the hitting rate for the overall observers was 184.51 surfaces and the diagnostic accuracy was 86.62%. 2. The diagnostic performance of the sound proximal tooth surfaces was very high, i.e., 91.5% true negative rate and 8.5% false positive rate. 3. The diagnostic performance of the dentist group was higher than the student group (P 0.001).

  7. Sensor Selection for Aircraft Engine Performance Estimation and Gas Path Fault Diagnostics

    Science.gov (United States)

    Simon, Donald L.; Rinehart, Aidan W.

    2016-01-01

    This paper presents analytical techniques for aiding system designers in making aircraft engine health management sensor selection decisions. The presented techniques, which are based on linear estimation and probability theory, are tailored for gas turbine engine performance estimation and gas path fault diagnostics applications. They enable quantification of the performance estimation and diagnostic accuracy offered by different candidate sensor suites. For performance estimation, sensor selection metrics are presented for two types of estimators including a Kalman filter and a maximum a posteriori estimator. For each type of performance estimator, sensor selection is based on minimizing the theoretical sum of squared estimation errors in health parameters representing performance deterioration in the major rotating modules of the engine. For gas path fault diagnostics, the sensor selection metric is set up to maximize correct classification rate for a diagnostic strategy that performs fault classification by identifying the fault type that most closely matches the observed measurement signature in a weighted least squares sense. Results from the application of the sensor selection metrics to a linear engine model are presented and discussed. Given a baseline sensor suite and a candidate list of optional sensors, an exhaustive search is performed to determine the optimal sensor suites for performance estimation and fault diagnostics. For any given sensor suite, Monte Carlo simulation results are found to exhibit good agreement with theoretical predictions of estimation and diagnostic accuracies.

  8. Methodology for quantitative evaluation of diagnostic performance

    International Nuclear Information System (INIS)

    Metz, C.

    1981-01-01

    Of various approaches that might be taken to the diagnostic performance evaluation problem, Receiver Operating Characteristic (ROC) analysis holds great promise. Further development of the methodology for a unified, objective, and meaningful approach to evaluating the usefulness of medical imaging procedures is done by consideration of statistical significance testing, optimal sequencing of correlated studies, and analysis of observer performance

  9. Resilient actions in the diagnostic process and system performance.

    Science.gov (United States)

    Smith, Michael W; Davis Giardina, Traber; Murphy, Daniel R; Laxmisan, Archana; Singh, Hardeep

    2013-12-01

    Systemic issues can adversely affect the diagnostic process. Many system-related barriers can be masked by 'resilient' actions of frontline providers (ie, actions supporting the safe delivery of care in the presence of pressures that the system cannot readily adapt to). We explored system barriers and resilient actions of primary care providers (PCPs) in the diagnostic evaluation of cancer. We conducted a secondary data analysis of interviews of PCPs involved in diagnostic evaluation of 29 lung and colorectal cancer cases. Cases covered a range of diagnostic timeliness and were analysed to identify barriers for rapid diagnostic evaluation, and PCPs' actions involving elements of resilience addressing those barriers. We rated these actions according to whether they were usual or extraordinary for typical PCP work. Resilient actions and associated barriers were found in 59% of the cases, in all ranges of timeliness, with 40% involving actions rated as beyond typical. Most of the barriers were related to access to specialty services and coordination with patients. Many of the resilient actions involved using additional communication channels to solicit cooperation from other participants in the diagnostic process. Diagnostic evaluation of cancer involves several resilient actions by PCPs targeted at system deficiencies. PCPs' actions can sometimes mitigate system barriers to diagnosis, and thereby impact the sensitivity of 'downstream' measures (eg, delays) in detecting barriers. While resilient actions might enable providers to mitigate system deficiencies in the short run, they can be resource intensive and potentially unsustainable. They complement, rather than substitute for, structural remedies to improve system performance. Measures to detect and fix system performance issues targeted by these resilient actions could facilitate diagnostic safety.

  10. Effect of radiologists' diagnostic work-up volume on interpretive performance.

    Science.gov (United States)

    Buist, Diana S M; Anderson, Melissa L; Smith, Robert A; Carney, Patricia A; Miglioretti, Diana L; Monsees, Barbara S; Sickles, Edward A; Taplin, Stephen H; Geller, Berta M; Yankaskas, Bonnie C; Onega, Tracy L

    2014-11-01

    To examine radiologists' screening performance in relation to the number of diagnostic work-ups performed after abnormal findings are discovered at screening mammography by the same radiologist or by different radiologists. In an institutional review board-approved HIPAA-compliant study, the authors linked 651 671 screening mammograms interpreted from 2002 to 2006 by 96 radiologists in the Breast Cancer Surveillance Consortium to cancer registries (standard of reference) to evaluate the performance of screening mammography (sensitivity, false-positive rate [ FPR false-positive rate ], and cancer detection rate [ CDR cancer detection rate ]). Logistic regression was used to assess the association between the volume of recalled screening mammograms ("own" mammograms, where the radiologist who interpreted the diagnostic image was the same radiologist who had interpreted the screening image, and "any" mammograms, where the radiologist who interpreted the diagnostic image may or may not have been the radiologist who interpreted the screening image) and screening performance and whether the association between total annual volume and performance differed according to the volume of diagnostic work-up. Annually, 38% of radiologists performed the diagnostic work-up for 25 or fewer of their own recalled screening mammograms, 24% performed the work-up for 0-50, and 39% performed the work-up for more than 50. For the work-up of recalled screening mammograms from any radiologist, 24% of radiologists performed the work-up for 0-50 mammograms, 32% performed the work-up for 51-125, and 44% performed the work-up for more than 125. With increasing numbers of radiologist work-ups for their own recalled mammograms, the sensitivity (P = .039), FPR false-positive rate (P = .004), and CDR cancer detection rate (P women recalled per cancer detected from 17.4 for 25 or fewer mammograms to 24.6 for more than 50 mammograms. Increases in work-ups for any radiologist yielded significant

  11. Effect of Radiologists’ Diagnostic Work-up Volume on Interpretive Performance

    Science.gov (United States)

    Anderson, Melissa L.; Smith, Robert A.; Carney, Patricia A.; Miglioretti, Diana L.; Monsees, Barbara S.; Sickles, Edward A.; Taplin, Stephen H.; Geller, Berta M.; Yankaskas, Bonnie C.; Onega, Tracy L.

    2014-01-01

    Purpose To examine radiologists’ screening performance in relation to the number of diagnostic work-ups performed after abnormal findings are discovered at screening mammography by the same radiologist or by different radiologists. Materials and Methods In an institutional review board–approved HIPAA-compliant study, the authors linked 651 671 screening mammograms interpreted from 2002 to 2006 by 96 radiologists in the Breast Cancer Surveillance Consortium to cancer registries (standard of reference) to evaluate the performance of screening mammography (sensitivity, false-positive rate [FPRfalse-positive rate], and cancer detection rate [CDRcancer detection rate]). Logistic regression was used to assess the association between the volume of recalled screening mammograms (“own” mammograms, where the radiologist who interpreted the diagnostic image was the same radiologist who had interpreted the screening image, and “any” mammograms, where the radiologist who interpreted the diagnostic image may or may not have been the radiologist who interpreted the screening image) and screening performance and whether the association between total annual volume and performance differed according to the volume of diagnostic work-up. Results Annually, 38% of radiologists performed the diagnostic work-up for 25 or fewer of their own recalled screening mammograms, 24% performed the work-up for 0–50, and 39% performed the work-up for more than 50. For the work-up of recalled screening mammograms from any radiologist, 24% of radiologists performed the work-up for 0–50 mammograms, 32% performed the work-up for 51–125, and 44% performed the work-up for more than 125. With increasing numbers of radiologist work-ups for their own recalled mammograms, the sensitivity (P = .039), FPRfalse-positive rate (P = .004), and CDRcancer detection rate (P work-ups for any radiologist yielded significant increases in FPRfalse-positive rate (P = .011) and CDRcancer detection rate (P

  12. 40 CFR 35.2218 - Project performance.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 1 2010-07-01 2010-07-01 false Project performance. 35.2218 Section 35... STATE AND LOCAL ASSISTANCE Grants for Construction of Treatment Works § 35.2218 Project performance. (a... personnel; and (3) Advise the grantee whether the project is meeting the project performance standards. (c...

  13. Evaluation Of The Diagnostic Performance Of A Multimedia Medical Communications System.

    Science.gov (United States)

    Robertson, John G.; Coristine, Marjorie; Goldberg, Morris; Beeton, Carolyn; Belanger, Garry; Tombaugh, Jo W.; Hickey, Nancy M.; Millward, Steven F.; Davis, Michael; Whittingham, David

    1989-05-01

    The central concern of radiologists when evaluating Picture Archiving Communication System (PACS) is the diagnostic performance of digital images compared to the original analog versions of the same images. Considerable work has been done comparing the ROC curves of various types of digital systems to the corresponding analog systems for the detection of specific phantoms or diseases. Although the studies may notify the radiologists that for a specific lesion a digital system may perform as well as the analog system, it tells the radiologists very little about the impact on diagnostic performance of a digital system in the general practice of radiology. We describe in this paper an alternative method for evaluating the diagnostic performance of a digital system and a preliminary experiment we conducted to test the methodology.

  14. Study for the design method of multi-agent diagnostic system to improve diagnostic performance for similar abnormality

    International Nuclear Information System (INIS)

    Minowa, Hirotsugu; Gofuku, Akio

    2014-01-01

    Accidents on industrial plants cause large loss on human, economic, social credibility. In recent, studies of diagnostic methods using techniques of machine learning such as support vector machine is expected to detect the occurrence of abnormality in a plant early and correctly. There were reported that these diagnostic machines has high accuracy to diagnose the operating state of industrial plant under mono abnormality occurrence. But the each diagnostic machine on the multi-agent diagnostic system may misdiagnose similar abnormalities as a same abnormality if abnormalities to diagnose increases. That causes that a single diagnostic machine may show higher diagnostic performance than one of multi-agent diagnostic system because decision-making considering with misdiagnosis is difficult. Therefore, we study the design method for multi-agent diagnostic system to diagnose similar abnormality correctly. This method aimed to realize automatic generation of diagnostic system where the generation process and location of diagnostic machines are optimized to diagnose correctly the similar abnormalities which are evaluated from the similarity of process signals by statistical method. This paper explains our design method and reports the result evaluated our method applied to the process data of the fast-breeder reactor Monju

  15. Identifying High Performance ERP Projects

    OpenAIRE

    Stensrud, Erik; Myrtveit, Ingunn

    2002-01-01

    Learning from high performance projects is crucial for software process improvement. Therefore, we need to identify outstanding projects that may serve as role models. It is common to measure productivity as an indicator of performance. It is vital that productivity measurements deal correctly with variable returns to scale and multivariate data. Software projects generally exhibit variable returns to scale, and the output from ERP projects is multivariate. We propose to use Data Envelopment ...

  16. 30 CFR 250.520 - When do I have to perform a casing diagnostic test?

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 2 2010-07-01 2010-07-01 false When do I have to perform a casing diagnostic... Operations Casing Pressure Management § 250.520 When do I have to perform a casing diagnostic test? (a) You must perform a casing diagnostic test within 30 days after first observing or imposing casing pressure...

  17. Model of critical diagnostic reasoning: achieving expert clinician performance.

    Science.gov (United States)

    Harjai, Prashant Kumar; Tiwari, Ruby

    2009-01-01

    Diagnostic reasoning refers to the analytical processes used to determine patient health problems. While the education curriculum and health care system focus on training nurse clinicians to accurately recognize and rescue clinical situations, assessments of non-expert nurses have yielded less than satisfactory data on diagnostic competency. The contrast between the expert and non-expert nurse clinician raises the important question of how differences in thinking may contribute to a large divergence in accurate diagnostic reasoning. This article recognizes superior organization of one's knowledge base, using prototypes, and quick retrieval of pertinent information, using similarity recognition as two reasons for the expert's superior diagnostic performance. A model of critical diagnostic reasoning, using prototypes and similarity recognition, is proposed and elucidated using case studies. This model serves as a starting point toward bridging the gap between clinical data and accurate problem identification, verification, and management while providing a structure for a knowledge exchange between expert and non-expert clinicians.

  18. Thyroid Ultrasound: Change of Inter-observer Variability and Diagnostic Performance after Training

    International Nuclear Information System (INIS)

    Moon, Hee Jung; Kim, Eun Kyung; Kwak, Jin Young; Park, Jeong Seon

    2011-01-01

    To investigate and compare inter-observer variability and diagnostic performance of thyroid ultrasound (US) between a faculty member and observing residents. From October 2007 to June 2009, 18 residents underwent training in thyroid US section. Group 1 included 8 residents that were trained for the first time and group 2 included 10 residents that were trained for the second time. US features of nodules were recorded according to the composition, echogenicity, margin, calcifications, shape, and final assessment by a faculty member and residents, respectively. Following a discussion, a faculty member performed fine needle aspiration. Then, the inter-observer variability and diagnostic performance between a faculty member and residents were investigated and compared for US. In group 1, agreement for composition in resident 1, calcification for residents 5 and 6, and shape for resident 4 were slight, moderate, moderate, and moderate, respectively. In group 2, agreement for composition in residents 1 and 10 were moderate. Substantial or greater agreement was observed more frequently in group 2 than 1. The diagnostic performances for both the faculty and residents were high and not statistically different. Agreement for US features between a faculty and residents as well as diagnostic performance were high. Moreover, diagnostic performance of residents that underwent training a second time of training was higher than residents that underwent training only once

  19. Statistical evaluation of diagnostic performance topics in ROC analysis

    CERN Document Server

    Zou, Kelly H; Bandos, Andriy I; Ohno-Machado, Lucila; Rockette, Howard E

    2016-01-01

    Statistical evaluation of diagnostic performance in general and Receiver Operating Characteristic (ROC) analysis in particular are important for assessing the performance of medical tests and statistical classifiers, as well as for evaluating predictive models or algorithms. This book presents innovative approaches in ROC analysis, which are relevant to a wide variety of applications, including medical imaging, cancer research, epidemiology, and bioinformatics. Statistical Evaluation of Diagnostic Performance: Topics in ROC Analysis covers areas including monotone-transformation techniques in parametric ROC analysis, ROC methods for combined and pooled biomarkers, Bayesian hierarchical transformation models, sequential designs and inferences in the ROC setting, predictive modeling, multireader ROC analysis, and free-response ROC (FROC) methodology. The book is suitable for graduate-level students and researchers in statistics, biostatistics, epidemiology, public health, biomedical engineering, radiology, medi...

  20. Project Leadership and Quality Performance of Construction Projects

    Directory of Open Access Journals (Sweden)

    SPG Buba

    2017-05-01

    Full Text Available Background: The construction industry in Nigeria, is pigeonholed by poor quality of construction products as a result of the inherent corruption in the country. Lack of purposeful leadership and inappropriate choice of leadership styles in the industry have been attributed to project failure. Abandoned and failed projects are more predominant in the public sector which litters every corner of the country. Objectives: The objective of this paper is to assess the impact of leadership styles on quality performance criteria of public projects in Nigeria. Methodology: A total of 43 questionnaires were distributed to 3 key groups of respondents (Quantity Surveyors, Builders, and Architects who are project managers in Nigeria. Descriptive and Inferential statistics were used to analyse the data using the Statistical Package for Social Sciences (SPSS. Likert Scale was used to measure the independent variables (leadership style: facilitative, coaching, delegating and directing; and the level of achievement of projects based on the dependent variables (quality and function performance criteria which are: achieving highest aesthetic quality; and functional building that fits its purpose. Findings: The study revealed that Directing is the major leadership style used by project managers in Nigeria. Amongst the leadership styles which has the most impact on quality performance indicators is also directing which has the most relative influence on achieving highest aesthetic quality and functional building that fits its purpose. Conclusion/Recommendation/Way forward: The underlying relationship between Directing leadership styles and the performance criteria of achieving highest aesthetic quality and functional building that fits its purpose will be beneficial to the Nigerian construction environment.

  1. Constrained bayesian inference of project performance models

    OpenAIRE

    Sunmola, Funlade

    2013-01-01

    Project performance models play an important role in the management of project success. When used for monitoring projects, they can offer predictive ability such as indications of possible delivery problems. Approaches for monitoring project performance relies on available project information including restrictions imposed on the project, particularly the constraints of cost, quality, scope and time. We study in this paper a Bayesian inference methodology for project performance modelling in ...

  2. Poor academic performance: A perspective of final year diagnostic radiography students

    International Nuclear Information System (INIS)

    Gqweta, Ntokozo

    2012-01-01

    Introduction: A study was conducted on final year diagnostic radiography students at a University of Technology in Durban. The aim of the study was to investigate the final year diagnostic radiography students' opinions and views on academic performance in order to inform teaching and learning methods. The objectives were: •To explore the students' opinions regarding poor performance. •To identify strategies to improve academic performance. Method: A qualitative, interpretive approach was used to explain and understand the students' lived experiences of their academic performances. A short open ended questionnaire was administered to a cohort of final diagnostic radiography students following feedback on a written assessment. Questionnaire responses were then manually captured and analyzed. Results: Five (5) themes were identified that could possibly be associated with poor academic performance. These themes were, poor preparation, lack of independent study, difficulty in understanding learning content and misinterpretation of assessment questions, inefficient studying techniques as well as perceived improvement strategies. Conclusion: Students identified their inadequate preparation and the lack of dedicated independent studying as the main reasons for poor performance. Students preferred to be taught in an assessment oriented manner. However their identified improvement strategies were aligned with the learner centred approach.

  3. Ambidextrous Leadership and Sustainability-Based Project Performance: The Role of Project Culture

    Directory of Open Access Journals (Sweden)

    Junwei Zheng

    2017-12-01

    Full Text Available Most studies in the project management field emphasized the effects of leaders or managers, but these effects have rarely been examined at the project level. To cover this research gap, this study applies organizational ambidexterity theory to examine the effects among ambidextrous leadership, ambidextrous culture and sustainability-based project performance. Using a valid sample of 217 project leaders and members from Chinese construction projects, the method of multiple linear regression was adopted to assess the direct relationship among ambidextrous leadership, ambidextrous culture and project performance. Moreover, the bootstrapping technique through structural equation modeling, has been used to analyze the mediating effect of ambidextrous culture. Additionally, the sample data was divided into different groups according to the median value of the variables to conduct the ANOVA and to assess the within-group differences. The results indicated a positive and direct relationship that ambidextrous leadership has on project performance and ambidextrous culture. In addition, there was also a mediating impact of ambidextrous leadership on project performance via ambidextrous culture. Thus, ambidextrous leadership combined with transformational leadership as well as transactional leadership likely has a stronger positive impact on project performance through fostering the adaptive culture and consistent culture. Our findings contribute to an in-depth understanding of the role of the leader and culture for project outcomes. The project-based organization in construction projects could train project leaders’ ambidextrous leadership behavior to facilitate the formation of an ambidextrous culture and to increase project performance. Moreover, this study enriches the existing literature on leadership and project management by highlighting the important path of ambidextrous leadership and ambidextrous culture on the performance at the project level

  4. Study of the performance of diagnostic radiology instruments during calibration

    International Nuclear Information System (INIS)

    Freitas, Rodrigo N. de; Vivolo, Vitor; Potiens, Maria da Penha A.

    2008-01-01

    Full text: The instruments used in diagnostic radiology measurements represent 8 % of the tested instruments by the calibration laboratory of IPEN annually (approximately 1600 in 2007). Considering that the calibration of this kind of instrument is performed biannually it is possible to conclude that almost 300 instruments are being used to measure the air kerma in diagnostic radiology clinics to determine the in beam values (in front of the patient), attenuated measurements (behind the patient) and scattered radiation. This work presents the results of the calibration of the instruments used in mammography, computed tomography, dental and conventional diagnostic radiology dosimetry, performed during the period of 2005 to 2007. Their performances during the calibrations measurements were evaluated. Although at the calibration laboratory there are three available series of radiation quality to this type of calibration (RQR, N and M, according to standards IEC 61267 and ISO 4037-1.), the applications can be assorted (general radiology, computed tomography, mammography, radiation protection and fluoroscopy). Depending on its design and behaviour , one kind of instrument can be used for one or more type of applications. The instruments normally used for diagnostic radiology measurements are ionization chambers with volumes varying from 3 to 1800 cm 3 , and can be cylindrical, spherical or plane parallel plates kind. They usually are sensitive to photon particles, with energies greater than 15 keV and can be used up to 1200 keV. In this work they were tested in X radiation fields from 25 to 150 kV, in specific qualities depending on the utilization of the instrument. The calibration results of 390 instruments received from 2005 to 2007 were analyzed. About 20 instruments were not able to be calibrated due to bad functioning. The calibration coefficients obtained were between 0.88 and 1.24. The uncertainties were always less than ± 3.6% to instruments used in scattered

  5. The ITER bolometer diagnostic: Status and plans

    International Nuclear Information System (INIS)

    Meister, H.; Giannone, L.; Horton, L. D.; Raupp, G.; Zeidner, W.; Grunda, G.; Kalvin, S.; Fischer, U.; Serikov, A.; Stickel, S.; Reichle, R.

    2008-01-01

    A consortium consisting of four EURATOM Associations has been set up to develop the project plan for the full development of the ITER bolometer diagnostic and to continue urgent R and D activities. An overview of the current status is given, including detector development, line-of-sight optimization, performance analysis as well as the design of the diagnostic components and their integration in ITER. This is complemented by the presentation of plans for future activities required to successfully implement the bolometer diagnostic, ranging from the detector development over diagnostic design and prototype testing to RH tools for calibration.

  6. The ITER bolometer diagnostic: Status and plansa)

    Science.gov (United States)

    Meister, H.; Giannone, L.; Horton, L. D.; Raupp, G.; Zeidner, W.; Grunda, G.; Kalvin, S.; Fischer, U.; Serikov, A.; Stickel, S.; Reichle, R.

    2008-10-01

    A consortium consisting of four EURATOM Associations has been set up to develop the project plan for the full development of the ITER bolometer diagnostic and to continue urgent R&D activities. An overview of the current status is given, including detector development, line-of-sight optimization, performance analysis as well as the design of the diagnostic components and their integration in ITER. This is complemented by the presentation of plans for future activities required to successfully implement the bolometer diagnostic, ranging from the detector development over diagnostic design and prototype testing to RH tools for calibration.

  7. 36 CFR 64.11 - Project performance.

    Science.gov (United States)

    2010-07-01

    ... 36 Parks, Forests, and Public Property 1 2010-07-01 2010-07-01 false Project performance. 64.11 Section 64.11 Parks, Forests, and Public Property NATIONAL PARK SERVICE, DEPARTMENT OF THE INTERIOR GRANTS... Project performance. The State or local applicant shall be responsible for insuring the project is carried...

  8. Acoustic detection in superconducting magnets for performance characterization and diagnostics

    OpenAIRE

    Marchevsky, M.; Wang, X.; Sabbi, G.; Prestemon, S.

    2014-01-01

    Quench diagnostics in superconducting accelerator magnets is essential for understanding performance limitations and improving magnet design. Applicability of the conventional quench diagnostics methods such as voltage taps or quench antennas is limited for long magnets or complex winding geometries, and alternative approaches are desirable. Here, we discuss acoustic sensing technique for detecting mechanical vibrations in superconducting magnets. Using LARP high-field Nb3Sn quadrupole HQ01 [...

  9. Pilot project for a commercial buildings Energy Analysis and Diagnostic Center (EADC) program. Final report

    Energy Technology Data Exchange (ETDEWEB)

    Capehart, B.L.

    1996-02-01

    Commercial energy use costs businesses around $70 billion annually. Many of these businesses are small and medium sized organizations that do not have the resources to help themselves, or to pay for professional engineering services to help reduce their energy costs and improve their economic competitiveness. Energy cost reduction actions with payback times of around two years could save the commercial sector 15--20%, or $10--$15 billion per year. This project was initially intended to evaluate the feasibility of performing commercial energy audits as an adjunct to the industrial audit program run by the US Department of Energy Industrial Office. This program is housed in 30 universities throughout the United States. Formerly known as Energy Analysis and Diagnostic Centers (EADC`s), the university programs are now called Industrial Assessment Centers (IAC`s) to reflect their expansion from energy use analyses to include waste and productivity analyses. The success of the EADC/IAC program in helping the manufacturing sector provides an excellent model for a similar program in the commercial buildings sector. This project has investigated using the EADC/IAC approach to performing energy audits for the commercial sector, and has determined that such an approach is feasible and cost effective.

  10. 44 CFR 206.204 - Project performance.

    Science.gov (United States)

    2010-10-01

    ... 44 Emergency Management and Assistance 1 2010-10-01 2010-10-01 false Project performance. 206.204... § 206.204 Project performance. (a) General. This section describes the policies and procedures applicable during the performance of eligible work. (b) Advances of funds. Advances of funds will be made in...

  11. International quality assurance project in colorectal cancer-unifying diagnostic and histopathological evaluation.

    Science.gov (United States)

    Jannasch, O; Udelnow, A; Romano, G; Dziki, A; Pavalkis, D; Lippert, H; Mroczkowski, P

    2014-04-01

    Several European countries are undertaking quality control projects in colorectal cancer. These efforts have led to improvements in survival, but a comparison between different projects reveals questionable results. The aim of this study is the presentation of results from hospitals in three different European countries participating in the International Quality Assurance in Colorectal Cancer (IQACC) project. For this publication, patients with cancer of the colon or rectum treated in 2009 and 2010 and recorded in the IQACC (Germany, Poland and Italy) were analysed. The comparison included number of patients, age, preoperative diagnostics (CT of the abdomen and thorax, MRI, colonoscopy, ultrasound, tumour markers), surgical approach, metastasis, height of rectal cancer and histopathological examination of a specimen (T stage, N stage and MERCURY classification for rectum resection). For short-term outcomes, general complications, wound dehiscence, tumour-free status at discharge, anastomotic leakage and in-hospital mortality were analysed. A total of 12,691 patients (6,756 with colon cancer, 5,935 with rectal cancer) were included in the analysis. Preoperative diagnostics differed significantly between countries. For pT and pN stages, several quality differences could be demonstrated, including missing stages (colon cancer: pT 5.7-12.5 %, pN 2.5-11.0 %; rectal cancer: pT 1.1-5.6 %, pN 1.1-15.5 %). The most relevant differences for short-term outcomes in colon cancer were found in general complications (4.2-22.8 %) and tumour-free status at discharge (74.5-91.7 %). In-hospital deaths ranged between 2.5 and 4.3 % and did not show significant differences. For rectal cancer, the country with the highest percentage of tumours localised less than 4 cm from the anal verge (16.0 %) showed the lowest frequency of amputation (8.5 %). Outcome differences were found for general complications (3.2-18.8 %), anastomotic leakage (0-4.3 %) and tumour-free status at discharge (72

  12. The European Union CREATE project: a model for international standardization of allergy diagnostics and vaccines

    NARCIS (Netherlands)

    Chapman, Martin D.; Ferreira, Fatima; Villalba, Mayte; Cromwell, Oliver; Bryan, Donna; Becker, Wolf-Meinhard; Fernández-Rivas, Montserrat; Durham, Stephen; Vieths, Stefan; van Ree, Ronald; Aalbers, M.; Notten, S.; Ooievaar-de Heer, P.; Ferreira, F.; Gademaier, G.; Wallner, M.; Villalba, M.; Rodriguez, R.; Becker, W.-M.; Eberhardt, F.; Lepp, U.; Raulf-Heimsoth, M.; Valenta, R.; Focke, M.; Bryan, D.; Dolman, C.; Das, R. G.; Vieths, S.; Fötisch, K.; Di Felice, G.; Pini, C.; Cromwell, O.; Fiebig, H.; Weber, B.; van Schijndel, H.; Dorpema, J. W.; Marco, F. M.; Monsalve, R.; Barber, D.; Caldas, E. Fernandez; Moingeon, P.; Didierlaurent, A.; André, C.; Kroon, A.; Neubauer, A.; Chapman, M.; Vailes, L.; Tsay, A.; Durham, S.; Custovic, A.; Simpson, B.; Knulst, A.; Rivas, M. Fernández; Mancebo, E. Gonzalez; Bahima, A. Cistero; Moncin, M. M. San Miguel; Mari, A.; Kinaciyan, T.; Quiralte, J.; Pauli, G.; de Blay, F.; Purohit, A.; Rak, S.

    2008-01-01

    Allergen measurements are used extensively in the formulation of allergy diagnostics and vaccines, yet no purified international allergen standards are available for calibration purposes. The aims of the European Union CREATE project were to develop international standards with verifiable allergen

  13. Diagnostic accuracy of the detection of bone change using panoramic TMJ projection. Comparative study with limited cone-beam CT

    International Nuclear Information System (INIS)

    Araki, Kazuyuki; Okano, Tomohiro; Kataoka, Ryuta; Honda, Kazuya; Endo, Atsushi; Kaneko, Norikazu; Funahashi, Itsuo

    2008-01-01

    Panoramic temporoman joint (TMJ) projection is one of the alternative methods of conventional radiography, such as transcranial projection, for diagnosing temporomandibular joint disorder. There have been a few reports describing the diagnostic ability of this method. We evaluated the diagnostic accuracy of detecting bone change with panoramic TMJ projection. Fifty TMJs in 25 patients were examined. All TMJs were examined by panoramic TMJ projection (Hyper XF) and limited cone-beam CT (3D Accuitomo FPD; 3DX). Two observers evaluated the presence of bone change in the TMJ region using panoramic TMJ projection. One other observer evaluated the limited cone-beam CT for the presence and the pattern of bone changes in the TMJ region as the gold standard. Panoramic TMJ findings were evaluated with regard to sensitivity, specificity, and accuracy. Sensitivity, specificity and accuracy of the panoramic TMJ projection were 0.86, 0.76, and 0.82, respectively. These results and those of previous reports on other radiographic methods for TMJ suggest that panoramic TMJ projection is a useful method of screening for bone change due to TMJ disorder. (author)

  14. The Impact of Project Organizational Culture on the Performance of Construction Projects

    Directory of Open Access Journals (Sweden)

    Luong Hai Nguyen

    2017-05-01

    Full Text Available Cultural influence has recently received significant attention from academics due to its vital role in the success or failure of a project. In the construction industry, several empirical investigations have examined the influence of culture on project management. The aim of this study is to determine the impact of project organizational culture on the performance of construction projects. A total of 199 completed construction projects in Vietnam with specific data gathering through questionnaires were analyzed. The findings reveal that contractor commitment to contract agreements is the most significant cultural factor affecting project performance. Goal alignment and reliance, contractor commitment, and worker orientation (i.e., commitment to workers contribute to improved overall performance and participant satisfaction. Contractor commitment and cooperative orientation enhance labor productivity, whereas goal alignment and trust and contractor commitment ensure learning performance (i.e., learning from experience. The findings of this study may assist construction professionals in implementing practices that can contribute to the sustainability and success of construction projects.

  15. Beam Diagnostics Challenges in the FAIR Project at GSI

    International Nuclear Information System (INIS)

    Peters, Andreas; Forck, Peter

    2006-01-01

    The planned FAIR (Facility for Antiproton and Ion Research) project consists of two heavy ion synchrotrons and four large storage rings, the existing GSI facility together with a new high-current proton linac will be used as the injector chain. The fast cycling, superconducting synchrotrons are build for high current operation with the aim of secondary ion and antiproton production. A large variety of low current secondary beams as well as the antiprotons are stored and cooled in the four storage rings. A complex operation scheme with multiple use of transport lines is foreseen. This demands an exceptional high dynamic range for the beam instrumentation. Due to the enormous beam power, non-destructive methods are mandatory for high currents as well as for the low current secondary beams due to the low repetition rate. Precise measurements of all beam parameters and automatic steering or feedback capabilities are required due to the necessary exploitation of the full ring acceptances. Moreover, online beam-corrections with short response times are mandatory for the fast ramping super-conducting magnets. An overview of the challenges and projected innovative solutions for various diagnostic installations will be given

  16. Performance of diagnostic mammography differs in the United States and Denmark

    DEFF Research Database (Denmark)

    Jensen, Allan; Geller, Berta M; Gard, Charlotte C

    2010-01-01

    in the United States and Denmark. The performance of 93,585 diagnostic mammograms from 180 facilities contributing data to the US Breast Cancer Surveillance Consortium (BCSC) from 1999 to 2001 was compared to that of all 51,313 diagnostic mammograms performed at Danish clinics in 2000. We used the imaging...... workup's final assessment to determine sensitivity, specificity and an estimate of accuracy: area under the receiver-operating characteristics (ROCs) curve (AUC). Diagnostic mammography had slightly higher sensitivity in the United States (85%) than in Denmark (82%). In contrast, it had higher...... specificity in Denmark (99%) than in the United States (93%). The AUC was high in both countries: 0.91 in United States and 0.95 in Denmark. Denmark's higher accuracy may result from supplementary ultrasound examinations, which are provided to 74% of Danish women but only 37% to 52% of US women. In addition...

  17. A new approach to cost effective projects: High performance project teams

    International Nuclear Information System (INIS)

    Chambers, N.C.

    1994-01-01

    In low oil price environment in which environmental conditions are more challenging, reservoir characteristics less favourable and political risk increasing, successful projects are required in such cases. The present paper deals with the visionary process of establishing high performance project teams. According to the author, such project teams embody dynamic recognition of holism. Holism is achieved as an output from the process of establishing the drivers and enablers for success on a project. They are given birth during the unfolding of the operators development plans and contracting strategy. The paper discusses the main drivers of project teams comprising purpose and performance goals, selection, common approach, commitment and accountability, and financial alignment

  18. A new approach to cost effective projects: High performance project teams

    Energy Technology Data Exchange (ETDEWEB)

    Chambers, N.C. [Brown and Root Energy Services (United Kingdom)

    1994-12-31

    In low oil price environment in which environmental conditions are more challenging, reservoir characteristics less favourable and political risk increasing, successful projects are required in such cases. The present paper deals with the visionary process of establishing high performance project teams. According to the author, such project teams embody dynamic recognition of holism. Holism is achieved as an output from the process of establishing the drivers and enablers for success on a project. They are given birth during the unfolding of the operators development plans and contracting strategy. The paper discusses the main drivers of project teams comprising purpose and performance goals, selection, common approach, commitment and accountability, and financial alignment

  19. Diagnostics and performance evaluation of multikilohertz capacitors

    International Nuclear Information System (INIS)

    McDuff, G.; Nunnally, W.C.; Rust, K.; Sarjeant, J.

    1980-01-01

    The observed performance of nanofarad polypropylene-silicone oil, mica paper, and polytetrafluoroethylene-silicone oil capacitors discharged in a 100-ns, 1-kA pulse with a pulse repetition frequency of 1 kHz is presented. The test facility circuit, diagnostic parameters, and the preliminary test schedule are outlined as a basis for discussion of the observed failure locations and proposed failure mechanisms. Most of the test data and discussion presented involves the polypropylene-silicone oil units

  20. Comparative cost analysis -- computed tomography vs. alternative diagnostic procedures, 1977-1980

    International Nuclear Information System (INIS)

    Gempel, P.A.; Harris, G.H.; Evans, R.G.

    1977-12-01

    In comparing the total national cost of utilizing computed tomography (CT) for medically indicated diagnoses with that of conventional x-ray, ultrasonography, nuclear medicine, and exploratory surgery, this investigation concludes that there was little, if any, added net cost from CT use in 1977 or will there be in 1980. Computed tomography, generally recognized as a reliable and useful diagnostic modality, has the potential to reduce net costs provided that an optimal number of units can be made available to physicians and patients to achieve projected reductions in alternative procedures. This study examines the actual cost impact of CT on both cranial and body diagnostic procedures. For abdominal and mediastinal disorders, CT scanning is just beginning to emerge as a diagnostic modality. As such, clinical experience is somewhat limited and the authors assume that no significant reduction in conventional procedures took place in 1977. It is estimated that the approximately 375,000 CT body procedures performed in 1977 represent only a 5 percent cost increase over use of other diagnostic modalities. It is projected that 2,400,000 CT body procedures will be performed in 1980 and, depending on assumptions used, total body diagnostic costs will increase only slightly or be reduced. Thirty-one tables appear throughout the text presenting cost data broken down by types of diagnostic procedures used and projections by years. Appendixes present technical cost components for diagnostic procedures, the comparative efficacy of CT as revealed in abstracts of published literature, selected medical diagnoses, and references

  1. Managing project complexity : A study into adapting early project phases to improve project performance in large engineering projects

    NARCIS (Netherlands)

    Bosch-Rekveldt, M.G.C.

    2011-01-01

    Engineering projects become increasingly more complex and project complexity is assumed to be one of the causes for projects being delivered late and over budget. However, what this project complexity actually comprised of was unclear. To improve the overall project performance, this study focuses

  2. Planning for high performance project teams

    International Nuclear Information System (INIS)

    Reed, W.; Keeney, J.; Westney, R.

    1997-01-01

    Both industry-wide research and corporate benchmarking studies confirm the significant savings in cost and time that result from early planning of a project. Amoco's Team Planning Workshop combines long-term strategic project planning and short-term tactical planning with team building to provide the basis for high performing project teams, better project planning, and effective implementation of the Amoco Common Process for managing projects

  3. Identification of coordination factors affecting building projects performance

    Directory of Open Access Journals (Sweden)

    Wesam Salah Alaloul

    2016-09-01

    Full Text Available Construction projects performance requires improvement to fulfil the complexity of the stakeholders’ needs and expectations. Coordination process is proposed as an efficient solution for weak performance of construction projects. Therefore, coordination factors are vital in ensuring a successful implementation of all project phases. This study aimed to identify and prioritise coordination factors that influence the performance of building projects in Malaysian context. A vast body of literature on coordination process was reviewed and resulted in 53 coordination factor. Three rounds of Delphi technique were conducted. The most effective coordination factors were ranked based on the Relative Importance Index (RII such as Scheduling (RII = 0.97, Quality assurance plan (RII = 0.93, and all parties’ participation in plans (RII = 0.89. These coordination factors have fulfilled the research gap and provided better management and higher performance for project parties. The results offer insightful perspectives to define the most effective coordination factors, for addressing the dependency between project tasks and the parties to enhance project performance.

  4. Diagnostic Performance on Low Dose Computed Tomography For Acute Appendicitis Among Attending and Resident Radiologists

    International Nuclear Information System (INIS)

    Chang, Chih-Chen; Wong, Yon-Cheong; Wu, Cheng-Hsien; Chen, Huan-Wu; Wang, Li-Jen; Lee, Yu-Hsien; Wu, Patricia Wanping; Irama, Wiwan; Chen, Wei Yuan; Chang, Chee-Jen

    2016-01-01

    Low-dose computed tomography (LDCT) techniques can reduce exposure to radiation. Several previous studies have shown that radiation dose reduction in LDCT does not decrease the diagnostic performance for appendicitis among attending radiologists. But, the LDCT diagnostic performance for acute appendicitis in radiology residents with variable training levels has not been well discussed. To compare inter-observer and intra-observer differences of diagnostic performance on non-enhanced LDCT (NE-LDCT) and contrast-enhanced standard dose CT (CE-SDCT) for acute appendicitis among attending and resident radiologists. This retrospective study included 101 patients with suspected acute appendicitis who underwent NE-LDCT and CE-SDCT. The CT examinations were interpreted and recorded on a five-point scale independently by three attending radiologists and three residents with 4, 1 and 1 years of training. Diagnostic performance for acute appendicitis of all readers on both examinations was represented by area under receiver operating characteristic (ROC) curves. Inter-observer and intra-observer AUC values were compared using Jackknife FROC software on both modalities. The diagnostic accuracy of each reader on NE-LDCT was compared with body mass index (BMI) subgroups and noise using independent T test. Diagnostic performances for acute appendicitis were not statistically different for attending radiologists at both examinations. Better performance was noted on the CE-SDCT with a borderline significant difference (P = 0.05) for senior radiology resident. No statistical difference of AUC values was observed between attending radiologists and fourth year resident on both examinations. Statistically signifi@@cant differences of AUC values were observed between attending radiologists and first year residents (P = 0.001 ~ 0.018) on NE-LDCT. Diagnostic accuracies of acute appendicitis on NE-LDCT for each reader were not significantly related to BMI or noise. Attending radiologists

  5. A Hybrid Neural Network-Genetic Algorithm Technique for Aircraft Engine Performance Diagnostics

    Science.gov (United States)

    Kobayashi, Takahisa; Simon, Donald L.

    2001-01-01

    In this paper, a model-based diagnostic method, which utilizes Neural Networks and Genetic Algorithms, is investigated. Neural networks are applied to estimate the engine internal health, and Genetic Algorithms are applied for sensor bias detection and estimation. This hybrid approach takes advantage of the nonlinear estimation capability provided by neural networks while improving the robustness to measurement uncertainty through the application of Genetic Algorithms. The hybrid diagnostic technique also has the ability to rank multiple potential solutions for a given set of anomalous sensor measurements in order to reduce false alarms and missed detections. The performance of the hybrid diagnostic technique is evaluated through some case studies derived from a turbofan engine simulation. The results show this approach is promising for reliable diagnostics of aircraft engines.

  6. Diagnostic performance of 64-slice multidetector coronary computed tomographic angiography in women.

    Science.gov (United States)

    Jug, Borut; Gupta, Mohit; Papazian, Jenny; Li, Dong; Tsang, Janet; Bhatia, Harpreet; Karlsberg, Ronald; Budoff, Matthew

    2012-12-01

    Diagnostic approach to chest pain in women is challenging, but still under-investigated. The purpose of this study was to assess the diagnostic performance of 64-slice multidetector coronary computed tomographic angiography (CCTA) in women with chest pain. We included 606 patients--255 women and 351 men (mean age 61 ± 12 years for both)--who had been referred for a CCTA and an invasive coronary angiography (diagnostic standard) because of chest pain, either as part of clinical work-up in two urban medical centers or as part of the multicenter ACCURACY trial. On a patient-based model, the sensitivity, specificity, and positive predictive value (PPV) and negative predictive value to detect ≥50% and ≥70% stenosis were 98%, 84%, 87%, and 97% and 96%, 83%, 77%, and 97%, respectively, for women and 97%, 83%, 89%, and 95% and 94%, 91%, 90%, and 94%, respectively, for men. There were no statistically significant differences between men and women in diagnostic performance measures except for the PPV of detecting a ≥70% stenosis (P = .007). In women with chest pain, 64-slice multidetector CCTA is at least as sensitive and specific as in men. Our findings suggest that CCTA is a promising diagnostic tool for timely detection and/or exclusion of CAD in symptomatic intermediate-risk female populations.

  7. Acoustic detection in superconducting magnets for performance characterization and diagnostics

    International Nuclear Information System (INIS)

    Marchevsky, M; Wang, X; Sabbi, G; Prestemon, S

    2013-01-01

    Quench diagnostics in superconducting accelerator magnets is essential for understanding performance limitations and improving magnet design. Applicability of the conventional quench diagnostics methods such as voltage taps or quench antennas is limited for long magnets or complex winding geometries, and alternative approaches are desirable. Here, we discuss acoustic sensing technique for detecting mechanical vibrations in superconducting magnets. Using LARP high-field Nb3Sn quadrupole HQ01, we show how acoustic data is connected with voltage instabilities measured simultaneously in the magnet windings during provoked extractions and current ramps to quench. Instrumentation and data analysis techniques for acoustic sensing are reviewed. (author)

  8. Acoustic detection in superconducting magnets for performance characterization and diagnostics

    CERN Document Server

    Marchevsky, M.; Sabbi, G.; Prestemon, S.

    2013-01-01

    Quench diagnostics in superconducting accelerator magnets is essential for understanding performance limitations and improving magnet design. Applicability of the conventional quench diagnostics methods such as voltage taps or quench antennas is limited for long magnets or complex winding geometries, and alternative approaches are desirable. Here, we discuss acoustic sensing technique for detecting mechanical vibrations in superconducting magnets. Using LARP high-field Nb$_{3}$Sn quadrupole HQ01 [1], we show how acoustic data is connected with voltage instabilities measured simultaneously in the magnet windings during provoked extractions and current ramps to quench. Instrumentation and data analysis techniques for acoustic sensing are reviewed.

  9. Tomosynthesis for the early detection of pulmonary emphysema: diagnostic performance compared with chest radiography, using multidetector computed tomography as reference.

    Science.gov (United States)

    Yamada, Yoshitake; Jinzaki, Masahiro; Hashimoto, Masahiro; Shiomi, Eisuke; Abe, Takayuki; Kuribayashi, Sachio; Ogawa, Kenji

    2013-08-01

    To compare the diagnostic performance of tomosynthesis with that of chest radiography for the detection of pulmonary emphysema, using multidetector computed tomography (MDCT) as reference. Forty-eight patients with and 63 without pulmonary emphysema underwent chest MDCT, tomosynthesis and radiography on the same day. Two blinded radiologists independently evaluated the tomosynthesis images and radiographs for the presence of pulmonary emphysema. Axial and coronal MDCT images served as the reference standard and the percentage lung volume with attenuation values of -950 HU or lower (LAA-950) was evaluated to determine the extent of emphysema. Receiver-operating characteristic (ROC) analysis and generalised estimating equations model were used. ROC analysis revealed significantly better performance (P pulmonary emphysema. The average sensitivity, specificity, positive predictive value and negative predictive value of tomosynthesis were 0.875, 0.968, 0.955 and 0.910, respectively, whereas the values for radiography were 0.479, 0.913, 0.815 and 0.697, respectively. For both tomosynthesis and radiography, the sensitivity increased with increasing LAA-950. The diagnostic performance of tomosynthesis was significantly superior to that of radiography for the detection of pulmonary emphysema. In both tomosynthesis and radiography, the sensitivity was affected by the LAA-950. • Tomosynthesis showed significantly better diagnostic performance for pulmonary emphysema than radiography. • Interobserver agreement for tomosynthesis was significantly higher than that for radiography. • Sensitivity increased with increasing LAA -950 in both tomosynthesis and radiography. • Tomosynthesis imparts a similar radiation dose to two projection chest radiography. • Radiation dose and cost of tomosynthesis are lower than those of MDCT.

  10. A systematic review of the diagnostic performance of orthopedic physical examination tests of the hip.

    Science.gov (United States)

    Rahman, Labib Ataur; Adie, Sam; Naylor, Justine Maree; Mittal, Rajat; So, Sarah; Harris, Ian Andrew

    2013-08-30

    Previous reviews of the diagnostic performances of physical tests of the hip in orthopedics have drawn limited conclusions because of the low to moderate quality of primary studies published in the literature. This systematic review aims to build on these reviews by assessing a broad range of hip pathologies, and employing a more selective approach to the inclusion of studies in order to accurately gauge diagnostic performance for the purposes of making recommendations for clinical practice and future research. It specifically identifies tests which demonstrate strong and moderate diagnostic performance. A systematic search of Medline, Embase, Embase Classic and CINAHL was conducted to identify studies of hip tests. Our selection criteria included an analysis of internal and external validity. We reported diagnostic performance in terms of sensitivity, specificity, predictive values and likelihood ratios. Likelihood ratios were used to identify tests with strong and moderate diagnostic utility. Only a small proportion of tests reported in the literature have been assessed in methodologically valid primary studies. 16 studies were included in our review, producing 56 independent test-pathology combinations. Two tests demonstrated strong clinical utility, the patellar-pubic percussion test for excluding radiologically occult hip fractures (negative LR 0.05, 95% Confidence Interval [CI] 0.03-0.08) and the hip abduction sign for diagnosing sarcoglycanopathies in patients with known muscular dystrophies (positive LR 34.29, 95% CI 10.97-122.30). Fifteen tests demonstrated moderate diagnostic utility for diagnosing and/or excluding hip fractures, symptomatic osteoarthritis and loosening of components post-total hip arthroplasty. We have identified a number of tests demonstrating strong and moderate diagnostic performance. These findings must be viewed with caution as there are concerns over the methodological quality of the primary studies from which we have extracted our

  11. POTENTIALITIES OF DIAGNOSTICS AND DIFFERENTIAL DIAGNOSTICS OF STOMACH DISEASES BY MEANS OF USAGE OF HIGH-PERFORMANCE BLOOD SERUM LIQUID CHROMATOGRAPHY

    Directory of Open Access Journals (Sweden)

    O.P. Alexeeva

    2008-12-01

    Full Text Available 62 patients with the endoscopically and morphologicallyverified diagnosis of the chronic gastritis, 89 patients with the morphologically verified diagnosis of stomach cancer and 43 healthy persons ages 23 to 54 years have been examined. Potentialities of the usage of high-performance blood serum liquid chromatography have been studied for the purpose of diagnostics and differential diagnostics of chronic gastritis and stomach cancer. Blood serum driedextract was investigated by means of"Milichrome A02"chromatograph (Novosibirsk, "Econova" joint-stock company. The chromatograms were treated by the multivahate cluster analysis with the formation of pathologic three-dimensional characteristic state notably differed from the healthy human image. Diagnostic sensitivity of chronic gastritis and stomach cancer acounts for accordingly 92% and 96%. Diagnostic accuracy of the method comes to 94%.

  12. Project management metrics, KPIs, and dashboards a guide to measuring and monitoring project performance

    CERN Document Server

    Kerzner, Harold

    2013-01-01

    Today, with the growth of complex projects, stakeholder involvement in projects, advances in computer technology for dashboard designs, metrics, and key performance indicators for project management have become an important focus. This Second Edition of the bestselling book walks readers through everything from the basics of project management metrics and key performance indicators to establishing targets and using dashboards to monitor performance. The content is aligned with PMI's PMBOK Guide and stresses "value" as the main focal point.

  13. Improving Sustainability Performance for Public-Private-Partnership (PPP Projects

    Directory of Open Access Journals (Sweden)

    Liyin Shen

    2016-03-01

    Full Text Available Improving sustainability performance in developing infrastructure projects is an important strategy for pursuing the mission of sustainable development. In recent years, the business model of public-private-partnership (PPP is promoted as an effective approach in developing infrastructure projects. It is considered that the distribution of the contribution on project investment between private and public sectors is one of the key variables affecting sustainability performance of PPP-type projects. This paper examines the impacts of the contribution distribution between public and private sectors on project sustainability performance. A model named the sustainability performance-based evaluation model (SPbEM is developed for assisting the assessment of the level of sustainability performance of PPP projects. The study examines the possibility of achieving better sustainability through proper arrangement of the investment distribution between the two primary sectors in developing PPP-type infrastructure projects.

  14. Diagnostics and results from coaxial plasma gun development for the PLX- α project

    Science.gov (United States)

    Case, A.; Brockington, S.; Cruz, E.; Witherspoon, F. D.

    2016-10-01

    We present results from the diagnostics used during development of the contoured gap coaxial plasma guns for the PLX- α project at LANL. Plasma-jet diagnostics include fast photodiodes for velocimetry, a ballistic pendulum for total plasmoid momentum, and interferometry for line integrated density. Deflectometry will be used for line integrated perpendicular density gradients. Time-resolved high-resolution spectroscopy using a novel detector and time-integrated survey spectroscopy are used for measurements of velocity and temperature, as well as impurities. We will also use a Faraday cup for density, fast imaging for plume geometry, and time-integrated imaging for overall light emission. Experimental results are compared to the desired target parameters for the plasma jets (up to n 2 ×1016cm-3 , v 50km / s , mass 5gm , radius = 4cm , and length 10cm). This work supported by the ARPA-E ALPHA Program.

  15. Good performance in nuclear projects

    International Nuclear Information System (INIS)

    1989-01-01

    The nuclear industry has demonstrated good performance in many areas relating to the design, engineering, construction and operation of nuclear facilities. This report of an international symposium held in Tokyo highlights examples of good performance in nuclear projects which can aid the industry in seeking even better performance, thus strengthening the contribution nuclear energy can make to sustainable economic growth

  16. Detailed Performance Assessment for the ITER ECE Diagnostic

    Science.gov (United States)

    Rowan, W.; Austin, M.; Houshmandyar, S.; Phillips, P.; Beno, J.; Bryant, A.; Ouroua, A.; Weeks, D.; Hubbard, A.; Taylor, G.

    2017-10-01

    One of the primary diagnostics for electron temperature (Te) measurement on ITER is based on the detection of electron cyclotron emission (ECE) Here we describe the predicted performance of the newly completed ECE diagnostic design by quantitatively following the emission from the plasma to the instruments and including the calibration method to assess accuracy. Operation of the diagnostic at 5.3 T is the main interest here but critical features of the emission spectra for 2.65 T and 1.8 T will be described. ECE will be collected by two very similar optical systems: one a radial view, the other an oblique view. Both measurements are used for Te while the oblique view also allows detection of non-thermal distortion in the electron distribution. An in-vacuum calibration source is included in the front end of each view to calibrate out the effect of any degradation of in-vessel optics. Following collection, the emission is split into orthogonal polarizations and transmitted to the detection instruments via waveguides filled with dry nitrogen, a choice that simplifies construction and analysis. Near the instruments, a switchyard is used to select which polarization and view is detected by each instrument. The design for the radiometer used for 5.3 T will be described in detail. Supported by PPPL/US-DA via subcontract S013464-H to UT Austin.

  17. Diagnostic performance of increased overjet in Class II division 1 malocclusion and incisor trauma.

    Science.gov (United States)

    Baccetti, Tiziano; Giuntini, Veronica; Vangelisti, Andrea; Darendeliler, M Ali; Franchi, Lorenzo

    2010-01-01

    The objectives of this study were: 1) to evaluate the associations between an increased overjet (IO) and other dentoskeletal characteristics of Class II division 1 malocclusions in the mixed dentition; 2) to assess whether Class II division 1 malocclusions or rather an increased overjet per se is a risk factor for upper incisor trauma (UIT). A sample of 900 mixed dentition subjects, was observed by clinical inspection, analysis of dental casts, and lateral cephalograms. The diagnostic performance of IO (overjet ≥ 7 mm) was evaluated in relation to other Class II dentoskeletal features (Class II molar and canine relationships, and skeletal Class II relationships). Secondly, the diagnostic performance of IO and of the other Class II dentoskeletal components was tested with regard to the prevalence of UIT. Diagnostic performance was assessed by odds ratio and positive likelihood ratio. The diagnostic performance of IO with regard to the other dentoskeletal components of Class II malocclusions was not significant. The only Class II features associated significantly with an increased risk of UIT was IO. When used as an isolated occlusal feature, IO is not a valid diagnostic indicator for Class II division 1 malocclusions. An increased overjet per se, and not Class II malocclusions, appears to be a significant risk factor for UIT. These findings recommend discrimination between clinical conditions showing an isolated IO from comprehensive Class II malocclusions during diagnosis, analysis of treatment outcomes, and evaluation of the risk of upper incisor trauma. Copyright © 2010 Società Italiana di Ortodonzia SIDO. Published by Elsevier Srl. All rights reserved.

  18. Benefits of a European project on diagnostics of highly pathogenic agents and assessment of potential "dual use" issues.

    Science.gov (United States)

    Grunow, Roland; Ippolito, G; Jacob, D; Sauer, U; Rohleder, A; Di Caro, A; Iacovino, R

    2014-01-01

    Quality assurance exercises and networking on the detection of highly infectious pathogens (QUANDHIP) is a joint action initiative set up in 2011 that has successfully unified the primary objectives of the European Network on Highly Pathogenic Bacteria (ENHPB) and of P4-laboratories (ENP4-Lab) both of which aimed to improve the efficiency, effectiveness, and response capabilities of laboratories directed at protecting the health of European citizens against high consequence bacteria and viruses of significant public health concern. Both networks have established a common collaborative consortium of 37 nationally and internationally recognized institutions with laboratory facilities from 22 European countries. The specific objectives and achievements include the initiation and establishment of a recognized and acceptable quality assurance scheme, including practical external quality assurance exercises, comprising living agents, that aims to improve laboratory performance, accuracy, and detection capabilities in support of patient management and public health responses; recognized training schemes for diagnostics and handling of highly pathogenic agents; international repositories comprising highly pathogenic bacteria and viruses for the development of standardized reference material; a standardized and transparent Biosafety and Biosecurity strategy protecting healthcare personnel and the community in dealing with high consequence pathogens; the design and organization of response capabilities dealing with cross-border events with highly infectious pathogens including the consideration of diagnostic capabilities of individual European laboratories. The project tackled several sensitive issues regarding Biosafety, Biosecurity and "dual use" concerns. The article will give an overview of the project outcomes and discuss the assessment of potential "dual use" issues.

  19. MEASURING THE PERFORMANCE OF GUYANA’S CONSTRUCTION INDUSTRY USING A SET OF PROJECT PERFORMANCE BENCHMARKING METRICS

    Directory of Open Access Journals (Sweden)

    Christopher J. Willis

    2011-10-01

    Full Text Available A study measuring the performance of Guyana’s construction industry using a set of project performance benchmarking metrics was recently completed. The underlying premise of the study was that the aggregated performance of construction projects provides a realistic assessment of the performance of the construction industry, on the basis that construction projects are the mechanism through which the construction industry creates its tangible products. The fact that an influential government agency acted as owner of the study was critical to the data collection phase. The best approach for collecting project performance data in Guyana involves the utilisation of a researcher or team of researchers mining electronic and hard copy project documents. This study analysed approximately 270 construction projects to obtain an indication of the performance of guyana’s construction industry. It was found that sea defence projects performed the worst, whereas health facility projects performed the best. The main implication of this is that sea defence projects are likely to be the least efficient and, given their critical nature, there is an argument for urgent performance improvement interventions.

  20. Overview of MFTF supervisory control and diagnostics system software

    International Nuclear Information System (INIS)

    Ng, W.C.

    1979-01-01

    The Mirror Fusion Test Facility (MFTF) at the Lawrence Livermore Laboratory (LLL) is currently the largest mirror fusion research project in the world. Its Control and Diagnostics System is handled by a distributed computer network consisting of nine Interdata minicomputer systems and about 65 microprocessors. One of the design requirements is tolerance of single-point failure. If one of the computer systems becomes inoperative, the experiment can still be carried out, although the system responsiveness to operator command may be degraded. In a normal experiment cycle, the researcher can examine the result of the previous experiment, change any control parameter, fire a shot, collect four million bytes of diagnostics data, perform intershot analysis, and have the result presented - all within five minutes. The software approach adopted for the Supervisory Control and Diagnostics System features chief programmer teams and structured programming. Pascal is the standard programming language in this project

  1. A framework to improve performance measurement in engineering projects

    OpenAIRE

    Zheng , Li; Baron , Claude; Esteban , Philippe; Xue , Rui; Zhang , Qiang

    2017-01-01

    International audience; A wide range of methods and good practices have been developed for the measurement of projects performance. They help project managers to effectively monitor the project progress and evaluate results. However, from a literature review, we noticed several remaining critical issues in measuring projects performance, such as an unbalanced development of Key Performance Indicators types between lagging and leading indicators. On the other hand, systems engineering measurem...

  2. Summary of the evidence file demonstrating completion of the NIF Project Completion Criteria

    Energy Technology Data Exchange (ETDEWEB)

    Haynam, C. A. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States)

    2014-12-04

    This document summarizes the results of performance verification tests on NIF that demonstrate it has met its performance-related Project Completion Criteria (PCC). It includes measurements made on NIF with the NIF diagnostics, the calibration of these diagnostics and the supporting analyses that verify the NIF performance criteria have been met.

  3. Project management metrics, KPIs, and dashboards a guide to measuring and monitoring project performance

    CERN Document Server

    Kerzner, Harold

    2017-01-01

    With the growth of complex projects, stakeholder involvement, and advancements in visual-based technology, metrics and KPIs (key performance indicators) are key factors in evaluating project performance. Dashboard reporting systems provide accessible project performance data, and sharing this vital data in a concise and consistent manner is a key communication responsibility of all project managers. This 3rd edition of Kerzner’s groundbreaking work includes the following updates: new sections on processing dashboard information, portfolio management PMO and metrics, and BI tool flexibility. PPT decks by chapter and a test bank will be available for use in seminar presentations and courses.

  4. An Integrated Architecture for On-Board Aircraft Engine Performance Trend Monitoring and Gas Path Fault Diagnostics

    Science.gov (United States)

    Simon, Donald L.

    2010-01-01

    Aircraft engine performance trend monitoring and gas path fault diagnostics are closely related technologies that assist operators in managing the health of their gas turbine engine assets. Trend monitoring is the process of monitoring the gradual performance change that an aircraft engine will naturally incur over time due to turbomachinery deterioration, while gas path diagnostics is the process of detecting and isolating the occurrence of any faults impacting engine flow-path performance. Today, performance trend monitoring and gas path fault diagnostic functions are performed by a combination of on-board and off-board strategies. On-board engine control computers contain logic that monitors for anomalous engine operation in real-time. Off-board ground stations are used to conduct fleet-wide engine trend monitoring and fault diagnostics based on data collected from each engine each flight. Continuing advances in avionics are enabling the migration of portions of the ground-based functionality on-board, giving rise to more sophisticated on-board engine health management capabilities. This paper reviews the conventional engine performance trend monitoring and gas path fault diagnostic architecture commonly applied today, and presents a proposed enhanced on-board architecture for future applications. The enhanced architecture gains real-time access to an expanded quantity of engine parameters, and provides advanced on-board model-based estimation capabilities. The benefits of the enhanced architecture include the real-time continuous monitoring of engine health, the early diagnosis of fault conditions, and the estimation of unmeasured engine performance parameters. A future vision to advance the enhanced architecture is also presented and discussed

  5. Analysis of Factors Influencing Building Refurbishment Project Performance

    Science.gov (United States)

    Ishak, Nurfadzillah; Aswad Ibrahim, Fazdliel; Azizi Azizan, Muhammad

    2018-03-01

    Presently, the refurbishment approach becomes favourable as it creates opportunities to incorporate sustainable value with other building improvement. In this regard, this approach needs to be implemented due to the issues on overwhelming ratio of existing building to new construction, which also can contribute to the environmental problem. Refurbishment principles imply to minimize the environmental impact and upgrading the performance of an existing building to meet new requirements. In theoretically, building project's performance has a direct bearing on related to its potential for project success. However, in refurbishment building projects, the criteria for measure are become wider because the projects are a complex and multi-dimensional which encompassing many factors which reflect to the nature of works. Therefore, this impetus could be achieve by examine the direct empirical relationship between critical success factors (CSFs) and complexity factors (CFs) during managing the project in relation to delivering success on project performance. The research findings will be expected as the basis of future research in establish appropriate framework that provides information on managing refurbishment building projects and enhancing the project management competency for a better-built environment.

  6. Wireless Infrastructure for Performing Monitoring, Diagnostics, and Control HVAC and Other Energy-Using Systems in Small Commercial Buildings

    Energy Technology Data Exchange (ETDEWEB)

    Patrick O' Neill

    2009-06-30

    This project focused on developing a low-cost wireless infrastructure for monitoring, diagnosing, and controlling building systems and equipment. End users receive information via the Internet and need only a web browser and Internet connection. The system used wireless communications for: (1) collecting data centrally on site from many wireless sensors installed on building equipment, (2) transmitting control signals to actuators and (3) transmitting data to an offsite network operations center where it is processed and made available to clients on the Web (see Figure 1). Although this wireless infrastructure can be applied to any building system, it was tested on two representative applications: (1) monitoring and diagnostics for packaged rooftop HVAC units used widely on small commercial buildings and (2) continuous diagnosis and control of scheduling errors such as lights and equipment left on during unoccupied hours. This project developed a generic infrastructure for performance monitoring, diagnostics, and control, applicable to a broad range of building systems and equipment, but targeted specifically to small to medium commercial buildings (an underserved market segment). The proposed solution is based on two wireless technologies. The first, wireless telemetry, is used for cell phones and paging and is reliable and widely available. This risk proved to be easily managed during the project. The second technology is on-site wireless communication for acquiring data from sensors and transmitting control signals. The technology must enable communication with many nodes, overcome physical obstructions, operate in environments with other electrical equipment, support operation with on-board power (instead of line power) for some applications, operate at low transmission power in license-free radio bands, and be low cost. We proposed wireless mesh networking to meet these needs. This technology is relatively new and has been applied only in research and tests

  7. The diagnostic performance of chronologic age in the assessment of skeletal maturity.

    Science.gov (United States)

    Baccetti, Tiziano; Franchi, Lorenzo; De Toffol, Laura; Ghiozzi, Bruno; Cozza, Paola

    2006-01-01

    The aim of this study was to analyze the relationship between chronologic age the and individual skeletal maturity as assessed by means of the cervical vertebral maturation (CVM) method during the circumpubertal period. The evaluated sample of 600 subjects consisted of 100 subjects (50 males and 50 females) for each of 6 age groups, from 9 years through 14 years of age. Individual skeletal maturity for all subjects was determined by using the CVM method. The relationship between chronologic age and the most prevalent CVM stage at each age group was evaluated statistically by means of indicators of diagnostic test performance that specify the ability of a diagnostic test to identify a condition. The diagnostic performance of chronologic age for the detection of the onset of the adolescent peak in skeletal maturation was very low both in males and in females. In male subjects, the chronologic age of 9 years +/- 6 months presented with strong diagnostic power for the identification of a pre-pubertal stage in skeletal maturation. In female subjects, the chronologic age of 14 years +/- 6 months corresponded with a strong probability of a postpubertal stage in skeletal maturation. In males, chronologic age can identify a pre-pubertal stage of skeletal development, and in females a post-pubertal stage. In both males and females, chronologic age cannot recognize the onset of the adolescent peak in skeletal maturation.

  8. Summary of EPRI projects for improving power plant maintenance and maintainability

    International Nuclear Information System (INIS)

    Shugars, H.G.; Poole, D.N.; Pack, R.W.

    1979-01-01

    The Electric Power Research Institute is sponsoring projects to improve power plant maintenance and maintainability. Areas presently being emphasized are improvements in plant design for maintainability, improvements in performing nuclear plant refuelings, and development of on-line monitoring and diagnostic systems for various plant components. The seven projects are reviewed. They are: (1) human factors review of power plant maintainability; (2) refueling outage improvement; (3) on-line monitoring and diagnostics for power plant machinery; (4) acoustic emission and vibrati1on signature analysis of fossil fuel plant components; (5) acoustic monitoring of power plant valves; (6) on-line monitoring and diagnostics for generators; and (7) detection of water induction in steam turbines. Each project contractor and the project manager are listed for reference. 8 references

  9. Optimized image acquisition for breast tomosynthesis in projection and reconstruction space

    International Nuclear Information System (INIS)

    Chawla, Amarpreet S.; Lo, Joseph Y.; Baker, Jay A.; Samei, Ehsan

    2009-01-01

    Breast tomosynthesis has been an exciting new development in the field of breast imaging. While the diagnostic improvement via tomosynthesis is notable, the full potential of tomosynthesis has not yet been realized. This may be attributed to the dependency of the diagnostic quality of tomosynthesis on multiple variables, each of which needs to be optimized. Those include dose, number of angular projections, and the total angular span of those projections. In this study, the authors investigated the effects of these acquisition parameters on the overall diagnostic image quality of breast tomosynthesis in both the projection and reconstruction space. Five mastectomy specimens were imaged using a prototype tomosynthesis system. 25 angular projections of each specimen were acquired at 6.2 times typical single-view clinical dose level. Images at lower dose levels were then simulated using a noise modification routine. Each projection image was supplemented with 84 simulated 3 mm 3D lesions embedded at the center of 84 nonoverlapping ROIs. The projection images were then reconstructed using a filtered backprojection algorithm at different combinations of acquisition parameters to investigate which of the many possible combinations maximizes the performance. Performance was evaluated in terms of a Laguerre-Gauss channelized Hotelling observer model-based measure of lesion detectability. The analysis was also performed without reconstruction by combining the model results from projection images using Bayesian decision fusion algorithm. The effect of acquisition parameters on projection images and reconstructed slices were then compared to derive an optimization rule for tomosynthesis. The results indicated that projection images yield comparable but higher performance than reconstructed images. Both modes, however, offered similar trends: Performance improved with an increase in the total acquisition dose level and the angular span. Using a constant dose level and angular

  10. Improving the diagnostic performance of lung scintigraphy in suspected pulmonary embolic disease

    International Nuclear Information System (INIS)

    Gleeson, F.V.; Turner, S.; Scarsbrook, A.F.

    2006-01-01

    Aim: to determine the effectiveness of a new imaging algorithm in the investigation of suspected pulmonary embolism (PE). Materials and methods: A new imaging algorithm for suspected PE was introduced following the installation of a multisection computed tomography (CT) machine at our institution. Before its installation, patients with suspected PE were evaluated with ventilation/perfusion (V/Q) scintigraphy. Subsequently, patients were triaged according to chest radiography (CR) and respiratory history to either lung scintigraphy or CT pulmonary angiography (CTPA). Patients with a normal CR and no history of lung disease were evaluated using perfusion (Q) scintigraphy [ventilation (V) scintigraphy was no longer performed]. Patients with an abnormal CR, asthma or chronic lung disease were evaluated using CTPA. All V/Q images in a continuous 3-year period before the introduction of the new imaging algorithm and all Q images performed in a 3-year period after its introduction were retrospectively reviewed. Imaging reports were categorized into normal, non-diagnostic (low or intermediate probability) or high probability for PE. Patients in the later group who subsequently underwent CTPA, were also reviewed. Results: After the policy change the percentage of normal scintigrams significantly increased (39 to 60%; p < 0.001). There was a non-significant increase in the percentage of high probability scintigrams (15 to 18%; p = 0.716). Overall the diagnostic yield of lung scintigraphy improved significantly (54 to 78%; p < 0.001). Conclusion: the diagnostic performance of lung scintigraphy can be improved by careful triage of patients to either Q scintigraphy or CTPA based on clinical history and CR findings. Q scintigraphy remains a valuable diagnostic test in the investigation of suspected PE in carefully selected patients

  11. Study on Fault Diagnostics of a Turboprop Engine Using Inverse Performance Model and Artificial Intelligent Methods

    Science.gov (United States)

    Kong, Changduk; Lim, Semyeong

    2011-12-01

    Recently, the health monitoring system of major gas path components of gas turbine uses mostly the model based method like the Gas Path Analysis (GPA). This method is to find quantity changes of component performance characteristic parameters such as isentropic efficiency and mass flow parameter by comparing between measured engine performance parameters such as temperatures, pressures, rotational speeds, fuel consumption, etc. and clean engine performance parameters without any engine faults which are calculated by the base engine performance model. Currently, the expert engine diagnostic systems using the artificial intelligent methods such as Neural Networks (NNs), Fuzzy Logic and Genetic Algorithms (GAs) have been studied to improve the model based method. Among them the NNs are mostly used to the engine fault diagnostic system due to its good learning performance, but it has a drawback due to low accuracy and long learning time to build learning data base if there are large amount of learning data. In addition, it has a very complex structure for finding effectively single type faults or multiple type faults of gas path components. This work builds inversely a base performance model of a turboprop engine to be used for a high altitude operation UAV using measured performance data, and proposes a fault diagnostic system using the base engine performance model and the artificial intelligent methods such as Fuzzy logic and Neural Network. The proposed diagnostic system isolates firstly the faulted components using Fuzzy Logic, then quantifies faults of the identified components using the NN leaned by fault learning data base, which are obtained from the developed base performance model. In leaning the NN, the Feed Forward Back Propagation (FFBP) method is used. Finally, it is verified through several test examples that the component faults implanted arbitrarily in the engine are well isolated and quantified by the proposed diagnostic system.

  12. Diagnostic performance of CT angiography in patients visiting emergency department with overt gastrointestinal bleeding

    International Nuclear Information System (INIS)

    Kim, Ji Hang; Kim, Young Hoon; Lee, Kyoung Ho; Lee, Yoon Jin; Park, Ji Hoon

    2015-01-01

    To investigate the diagnostic performance of computed tomography angiography (CTA) in identifying the cause of bleeding and to determine the clinical features associated with a positive test result of CTA in patients visiting emergency department with overt gastrointestinal (GI) bleeding. We included 111 consecutive patients (61 men and 50 women; mean age: 63.4 years; range: 28-89 years) who visited emergency department with overt GI bleeding. They underwent CTA as a first-line diagnostic modality from July through December 2010. Two radiologists retrospectively reviewed the CTA images and determined the presence of any definite or potential bleeding focus by consensus. An independent assessor determined the cause of bleeding based on other diagnostic studies and/or clinical follow-up. The diagnostic performance of CTA and clinical characteristics associated with positive CTA results were analyzed. To identify a definite or potential bleeding focus, the diagnostic yield of CTA was 61.3% (68 of 111). The overall sensitivity, specificity, positive predictive value (PPV), and negative predictive value were 84.8% (67 of 79), 96.9% (31 of 32), 98.5% (67 of 68), and 72.1% (31 of 43), respectively. Positive CTA results were associated with the presence of massive bleeding (p = 0.001, odds ratio: 11.506). Computed tomography angiography as a first-line diagnostic modality in patients presenting with overt GI bleeding showed a fairly high accuracy. It could identify definite or potential bleeding focus with a moderate diagnostic yield and a high PPV. CTA is particularly useful in patients with massive bleeding.

  13. Diagnostic value of high strength MRCP in the obstructive jaundice

    International Nuclear Information System (INIS)

    Yang Yang; Dong Yuhai; Yin Jie; Lv Guoyi

    2007-01-01

    Objective: To evaluate the diagnostic value of high strength MRCP in patients with obstructive jaundice. Methods: Routine MRI and MRCP examination on 161 patients with obstructive jaundice were carded out with 1.5T Siemens super-conductive magnetic resonance machine. Of them, 103 cases were benign lesions and 58 were malignant after surgical and ERCP pathological confirmation. Results: The diagnostic accuracy of MRCP was 100%, with the qualitative diagnostic accuracy at 90.2%. Conclusion: MRCP was the best method in diagnosing patients with obstructive jaundice, the concerned performances of MRCP could provide the dependable basis for surgical operation project. (authors)

  14. Analysis of architect’s performance indicators in project delivery process

    Science.gov (United States)

    Marisa, A.

    2018-03-01

    Architect as a professional in the construction industry should possess a good performance in project delivery process. As a design professional, architect has an important role to ensure that the process is well-conducted by delivering a high-quality product for the clients. Thus, analyzing architect’s performance indicators is crucial in the project delivery process. This study aims to analyze the relative importance of architect performance indicators in project delivery process among registered architects in North Sumatera, Indonesia. A total of five indicators that measure architect performance in project delivery process were identified and 110 completed questionnaires were obtained and used for data analysis. A relative importance index is used to rank the relative importance of architect performance indicators. Results indicate that focus on the clients is the most important indicator of architect performance in project delivery process. This study demonstrates project communication as one of crucial indicators perceived by the architects for measuring their performance, and fills a knowledge gap on the importance of identifying the most important indicator for measuring architect performance from their own perspectives which previous studies have overlooked to improve performance assessment in project delivery process.

  15. Peripheral occlusive vascular disease: Diagnostic performance of MRA and DSA

    International Nuclear Information System (INIS)

    Krug, B.; Kugel, H.; Harnischmacher, U.; Heindel, W.; Altenburg, A.; Fischbach, R.; Schmidt, R.

    1995-01-01

    In 59 patients with arterial flow disturbances 2-D inflow sequence of the abdominal and lower leg arteries were prospectively obtained on a 1.5 T MR-imager and were compared with additional DSA examinations. Supplementary Phase Contraste RSE ('Rapid Sequential Excitation') sequences were carried out in 29 patients. MRA and DSA angiograms were evaluated in random order by 4 readers using a questionnaire. The assessment of image quality were evaluated by variance analysis. Diagnostic performance of MRA and DSA was assessed by comparison of the readers' diagnostic assessments with reference diagnoses established by a radiologist and a vascular surgeon with full knowledge of all data concerning a patient. Image quality of inflow MRA was considered inferior to i.a. DSA (p [de

  16. Understanding new product project performance : A meta-analysis

    NARCIS (Netherlands)

    Commandeur, H.R.; Pattikawa, L.H.; Verwaal, E.

    2006-01-01

    Purpose: The purpose of this paper is to summarize the accumulated body of knowledge on the performance of new product projects and provide directions for further research. Design/methodology/approach: Using a refined classification of antecedents of new product project performance the research

  17. Analysis of Factors Influencing Building Refurbishment Project Performance

    Directory of Open Access Journals (Sweden)

    Ishak Nurfadzillah

    2018-01-01

    Full Text Available Presently, the refurbishment approach becomes favourable as it creates opportunities to incorporate sustainable value with other building improvement. In this regard, this approach needs to be implemented due to the issues on overwhelming ratio of existing building to new construction, which also can contribute to the environmental problem. Refurbishment principles imply to minimize the environmental impact and upgrading the performance of an existing building to meet new requirements. In theoretically, building project’s performance has a direct bearing on related to its potential for project success. However, in refurbishment building projects, the criteria for measure are become wider because the projects are a complex and multi-dimensional which encompassing many factors which reflect to the nature of works. Therefore, this impetus could be achieve by examine the direct empirical relationship between critical success factors (CSFs and complexity factors (CFs during managing the project in relation to delivering success on project performance. The research findings will be expected as the basis of future research in establish appropriate framework that provides information on managing refurbishment building projects and enhancing the project management competency for a better-built environment.

  18. Benefits of a European Project on Diagnostics of Highly Pathogenic Agents and Assessment of Potential “Dual Use” Issues

    Science.gov (United States)

    Grunow, Roland; Ippolito, G.; Jacob, D.; Sauer, U.; Rohleder, A.; Di Caro, A.; Iacovino, R.

    2014-01-01

    Quality assurance exercises and networking on the detection of highly infectious pathogens (QUANDHIP) is a joint action initiative set up in 2011 that has successfully unified the primary objectives of the European Network on Highly Pathogenic Bacteria (ENHPB) and of P4-laboratories (ENP4-Lab) both of which aimed to improve the efficiency, effectiveness, and response capabilities of laboratories directed at protecting the health of European citizens against high consequence bacteria and viruses of significant public health concern. Both networks have established a common collaborative consortium of 37 nationally and internationally recognized institutions with laboratory facilities from 22 European countries. The specific objectives and achievements include the initiation and establishment of a recognized and acceptable quality assurance scheme, including practical external quality assurance exercises, comprising living agents, that aims to improve laboratory performance, accuracy, and detection capabilities in support of patient management and public health responses; recognized training schemes for diagnostics and handling of highly pathogenic agents; international repositories comprising highly pathogenic bacteria and viruses for the development of standardized reference material; a standardized and transparent Biosafety and Biosecurity strategy protecting healthcare personnel and the community in dealing with high consequence pathogens; the design and organization of response capabilities dealing with cross-border events with highly infectious pathogens including the consideration of diagnostic capabilities of individual European laboratories. The project tackled several sensitive issues regarding Biosafety, Biosecurity and “dual use” concerns. The article will give an overview of the project outcomes and discuss the assessment of potential “dual use” issues. PMID:25426479

  19. Diagnostic Utility of the Social Skills Improvement System Performance Screening Guide

    Science.gov (United States)

    Krach, S. Kathleen; McCreery, Michael P.; Wang, Ye; Mohammadiamin, Houra; Cirks, Christen K.

    2017-01-01

    Researchers investigated the diagnostic utility of the Social Skills Improvement System: Performance Screening Guide (SSIS-PSG). Correlational, regression, receiver operating characteristic (ROC), and conditional probability analyses were run to compare ratings on the SSIS-PSG subscales of Prosocial Behavior, Reading Skills, and Math Skills, to…

  20. National NIF Diagnostic Program Interim Management Plan

    International Nuclear Information System (INIS)

    Warner, B

    2002-01-01

    The National Ignition Facility (NIF) has the mission of supporting Stockpile Stewardship and Basic Science research in high-energy-density plasmas. To execute those missions, the facility must provide diagnostic instrumentation capable of observing and resolving in time events and radiation emissions characteristic of the plasmas of interest. The diagnostic instrumentation must conform to high standards of operability and reliability within the NIF environment. These exacting standards, together with the facility mission of supporting a diverse user base, has led to the need for a central organization charged with delivering diagnostic capability to the NIF. The National NIF Diagnostics Program (NNDP) has been set up under the aegis of the NIF Director to provide that organization authority and accountability to the wide user community for NIF. The funds necessary to perform the work of developing diagnostics for NIF will be allocated from the National NIF Diagnostics Program to the participating laboratories and organizations. The participating laboratories and organizations will design, build, and commission the diagnostics for NIF. Restricted availability of funding has had an adverse impact, unforeseen at the time of the original decision to projectize NIF Core Diagnostics Systems and Cryogenic Target Handing Systems, on the planning and initiation of these efforts. The purpose of this document is to provide an interim project management plan describing the organizational structure and management processes currently in place for NIF Core Diagnostics Systems. Preparation of a Program Execution Plan for NIF Core Diagnostics Systems has been initiated and a current draft is provided as Attachment 1 to this document. The National NIF Diagnostics Program Interim Management Plan provides a summary of primary design criteria and functional requirements, current organizational structure, tracking and reporting procedures, and current planning estimates of project scope

  1. A Review of 20 Years of Research on Overdiagnosis and Underdiagnosis in the Rhode Island Methods to Improve Diagnostic Assessment and Services (MIDAS) Project.

    Science.gov (United States)

    Zimmerman, Mark

    2016-02-01

    The Rhode Island Methods to Improve Diagnostic Assessment and Services (MIDAS) project represents an integration of research methodology into a community-based outpatient practice affiliated with an academic medical centre. The MIDAS project is the largest clinical epidemiological study using semi-structured interviews to assess a wide range of psychiatric disorders in a general clinical outpatient practice. In an early report from the MIDAS project, we found that across diagnostic categories clinicians using unstandardized, unstructured clinical interviews underrecognized diagnostic comorbidity, compared with the results of semi-structured interviews. Moreover, we found that the patients often wanted treatment for symptoms of disorders that were diagnosed as comorbid, rather than principal, conditions. This highlighted the importance, from the patient's perspective, of conducting thorough diagnostic interviews to diagnose disorders that are not related to the patient's chief complaint because patients often desire treatment for these additional diagnoses. While several of the initial papers from the MIDAS project identified problems with the detection of comorbid disorders in clinical practice, regarding the diagnosis of bipolar disorder we observed the emergence of an opposite phenomenon-clinician overdiagnosis. The results from the MIDAS project, along with other studies of diagnosis in routine clinical practice, have brought to the forefront the problem with diagnosis in routine clinical practice. An important question is what do these findings suggest about the community standard of care in making psychiatric diagnoses, and whether and how the standard of care should be changed? The implications are discussed. © The Author(s) 2016.

  2. Diagnostic accuracy of mammography readers and their memory performance have no correlation with each other

    International Nuclear Information System (INIS)

    Kok, P.; Cawson, J.N.; Mercuri, V.; Pitman, A.G.; Gledhill, S.; Shnier, D.; Taft, R.; Zentner, L.

    2010-01-01

    Full text: The study aims to determine if any association exists between visual memory performance and diagnostic accuracy performance in a group of radiologist mammogram readers. Materials and Methods: One hundred proven mammograms (23 with cancers) were grouped into 5 sets of 20 cases, with sets being of equal difficulty. Pairs of sets were presented in 5 reads (40 cases per read, order random) to a panel of 8 radiologist readers (either present or past screening readers, with experience range from 20 years). The readers were asked to either 'clear' or 'call back' cases depending on need for further workup, and at post-baseline reads to indicate whether each case was 'new' or 'old' (i .e. remembered from prior read). Two sets were presented only at baseline (40 cases per reader), and were used to calculate the reader's false recollection rate. Three sets were repeated post-baseline once or twice (100 cases per reader). Reading conditions were standardised. Results: Memory performance differed markedly between readers. The number of correctly remembered cases (of 100 'old' cases) had a median of 10.5 and range of 0-58. The observed number of false recollections (of 40 'totally new' cases) had a median of 2 and range of 0-17. Diagnostic performance measures were mean (range): sensitivity 0.68 (0.54-0.81); specificity 0.82 (0.74-0.91); positive predictive value (PPV) 0.55 (0.500.65); negative predictive value (NPV) 0.89 (0.86-0.93) and accuracy 0.78 (0.76-0.83). Confidence intervals (CIs; 95%) for each reader overlapped for all the diagnostic parameters, indicating a lack of statistically significant difference between the readers at the 5% level. The most sensitive and the most specific reader showed a trend away from each other on sensitivity, specificity, NPV and PPV; their accuracies were 0.76 and 0.82, respectively, and their accuracy 95% CIs overlapped considerably. Correlation analysis by reader showed no association between observed memory performance and

  3. Transfer from point-of-care Ultrasonography training to diagnostic performance on patients--a randomized controlled trial

    DEFF Research Database (Denmark)

    Todsen, Tobias; Jensen, Morten Lind; Tolsgaard, Martin Grønnebæk

    2016-01-01

    BACKGROUND: Clinicians are increasingly using point-of-care ultrasonography for bedside examinations of patients. However, proper training is needed in this technique, and it is unknown whether the skills learned from focused Ultrasonography courses are being transferred to diagnostic performance...... test and binary logistic regression, respectively. RESULTS: There was a significant difference in the performance score between the intervention group (27.4%) and the control group (18.0%, P = .004) and the diagnostic accuracy between the intervention group (65%) and the control group (39%, P = .014......). CONCLUSIONS: Clinicians could successfully transfer learning from an Ultrasonography course to improve diagnostic performance on patients. However, our results also indicate a need for more training when new technologies such as point-of-care ultrasonography are introduced....

  4. Diagnostic performance of traditional hepatobiliary biomarkers of drug-induced liver injury in the rat.

    Science.gov (United States)

    Ennulat, Daniela; Magid-Slav, Michal; Rehm, Sabine; Tatsuoka, Kay S

    2010-08-01

    Nonclinical studies provide the opportunity to anchor biochemical with morphologic findings; however, liver injury is often complex and heterogeneous, confounding the ability to relate biochemical changes with specific patterns of injury. The aim of the current study was to compare diagnostic performance of hepatobiliary markers for specific manifestations of drug-induced liver injury in rat using data collected in a recent hepatic toxicogenomics initiative in which rats (n = 3205) were given 182 different treatments for 4 or 14 days. Diagnostic accuracy of alanine aminotransferase (ALT), aspartate aminotransferase (AST), total bilirubin (Tbili), serum bile acids (SBA), alkaline phosphatase (ALP), gamma glutamyl transferase (GGT), total cholesterol (Chol), and triglycerides (Trig) was evaluated for specific types of liver histopathology by Receiver Operating Characteristic (ROC) analysis. To assess the relationship between biochemical and morphologic changes in the absence of hepatocellular necrosis, a second ROC analysis was performed on a subset of rats (n = 2504) given treatments (n = 152) that did not cause hepatocellular necrosis. In the initial analysis, ALT, AST, Tbili, and SBA had the greatest diagnostic utility for manifestations of hepatocellular necrosis and biliary injury, with comparable magnitude of area under the ROC curve and serum hepatobiliary marker changes for both. In the absence of hepatocellular necrosis, ALT increases were observed with biochemical or morphologic evidence of cholestasis. In both analyses, diagnostic utility of ALP and GGT for biliary injury was limited; however, ALP had modest diagnostic value for peroxisome proliferation, and ALT, AST, and total Chol had moderate diagnostic utility for phospholipidosis. None of the eight markers evaluated had diagnostic value for manifestations of hypertrophy, cytoplasmic rarefaction, inflammation, or lipidosis.

  5. A multilevel study of the impact of project manager's leadership on extra-role performance of project team members

    Science.gov (United States)

    Shokory, Suzyanty Mohd; Suradi, Nur Riza Mohd

    2018-04-01

    The current study examines the impact of transformational and transactional leadership of project manager on the extra-role performance of project team members. In addition, this study also identifies factor dominant to extra-role performance of project team members when the transformational and transactional leadership of project managers are analyzed simultaneously. The study involved 175 of project team members from 35 project teams (each project team consists of different contracting companies registered in the Selangor (N = 175 from 35 contractors company). A multilevel analysis with hierarchical linear modeling (HLM) approach was used in this study. The analysis showed that transformational and transactional leadership of the project manager is a positive significant with extra-role performance project team members when analyzed separately. However when the two constructs (transformational leadership and transactional leadership of project manager) were analyzed simultaneously, transformational leadership was found to have more impact on extra-role performance project team members compared to transactional leadership. These findings explained that although transformational and transactional leadership of project managers can improve extra-role performance project team members, but this study has proved that transformational leadership of project managers affect extra-role performance project team members more as compared to transactional leadership.

  6. Causes of Low-Skilled Workers’ Performance in Construction Projects

    OpenAIRE

    Alhaji Ali Zannah; Aryani Ahmad Latiffi; Abdulazeez Umar Raji; Abdullahi Abba Waziri; Usman Mohammed 4

    2017-01-01

    Skilled workers’ performance is one of the crucial aspects of labour productivity that requires proper attention for effective projects delivery in the construction industry. The level of skilled workers’ low performance has been seen to be a major factor which contributes toward inefficient construction projects productivity. Therefore, the objective of this research is to identify the causes of low-skilled workers’ performance in construction projects in the Nigeria. The objective was achie...

  7. Diagnostic performance of semi-quantitative and quantitative stress CMR perfusion analysis: a meta-analysis.

    Science.gov (United States)

    van Dijk, R; van Assen, M; Vliegenthart, R; de Bock, G H; van der Harst, P; Oudkerk, M

    2017-11-27

    Stress cardiovascular magnetic resonance (CMR) perfusion imaging is a promising modality for the evaluation of coronary artery disease (CAD) due to high spatial resolution and absence of radiation. Semi-quantitative and quantitative analysis of CMR perfusion are based on signal-intensity curves produced during the first-pass of gadolinium contrast. Multiple semi-quantitative and quantitative parameters have been introduced. Diagnostic performance of these parameters varies extensively among studies and standardized protocols are lacking. This study aims to determine the diagnostic accuracy of semi- quantitative and quantitative CMR perfusion parameters, compared to multiple reference standards. Pubmed, WebOfScience, and Embase were systematically searched using predefined criteria (3272 articles). A check for duplicates was performed (1967 articles). Eligibility and relevance of the articles was determined by two reviewers using pre-defined criteria. The primary data extraction was performed independently by two researchers with the use of a predefined template. Differences in extracted data were resolved by discussion between the two researchers. The quality of the included studies was assessed using the 'Quality Assessment of Diagnostic Accuracy Studies Tool' (QUADAS-2). True positives, false positives, true negatives, and false negatives were subtracted/calculated from the articles. The principal summary measures used to assess diagnostic accuracy were sensitivity, specificity, andarea under the receiver operating curve (AUC). Data was pooled according to analysis territory, reference standard and perfusion parameter. Twenty-two articles were eligible based on the predefined study eligibility criteria. The pooled diagnostic accuracy for segment-, territory- and patient-based analyses showed good diagnostic performance with sensitivity of 0.88, 0.82, and 0.83, specificity of 0.72, 0.83, and 0.76 and AUC of 0.90, 0.84, and 0.87, respectively. In per territory

  8. Prodiag--a hybrid artificial intelligence based reactor diagnostic system for process faults

    International Nuclear Information System (INIS)

    Reifman, J.; Wei, T.Y.C.; Vitela, J.E.; Applequist, C. A.; Chasensky, T.M.

    1996-01-01

    Commonwealth Research Corporation (CRC) and Argonne National Laboratory (ANL) are collaborating on a DOE-sponsored Cooperative Research and Development Agreement (CRADA), project to perform feasibility studies on a novel approach to Artificial Intelligence (Al) based diagnostics for component faults in nuclear power plants. Investigations are being performed in the construction of a first-principles physics-based plant level process diagnostic expert system (ES) and the identification of component-level fault patterns through operating component characteristics using artificial neural networks (ANNs). The purpose of the proof-of-concept project is to develop a computer-based system using this Al approach to assist process plant operators during off-normal plant conditions. The proposed computer-based system will use thermal hydraulic (T-H) signals complemented by other non-T-H signals available in the data stream to provide the process operator with the component which most likely caused the observed process disturbance.To demonstrate the scale-up feasibility of the proposed diagnostic system it is being developed for use with the Chemical Volume Control System (CVCS) of a nuclear power plant. A full-scope operator training simulator representing the Commonwealth Edison Braidwood nuclear power plant is being used both as the source of development data and as the means to evaluate the advantages of the proposed diagnostic system. This is an ongoing multi-year project and this paper presents the results to date of the CRADA phase

  9. Diagnostics and structure

    International Nuclear Information System (INIS)

    Vial, J.C.

    1986-01-01

    The structure of prominences and the diagnostic techniques used to evaluate their physical parameters are discussed. These include electron temperature, various densities (n sub p, n sub e, n sub l), ionization degree, velocities, and magnetic field vector. UV and radio measurements have already evidenced the existence of different temperature regions, corresponding to different geometrical locations, e.g., the so called Prominence-Corona (P-C) interface. Velocity measurements are important for considering formation and mass balance of prominences but there are conflicting velocity measurements which have led to the basic question: what structure is actually observed at a given wavelength; what averaging is performed within the projected slit area during the exposure time? In optically thick lines, the question of the formation region of the radiation along the line of sight is also not a trivial one. The same is true for low resolution measurements of the magnetic field. Coupling diagnostics with structure is now a general preoccupation

  10. Static dosimetry space image in which urology diagnostics are performed

    International Nuclear Information System (INIS)

    Banduka, M.S.; Vasic, D.D.

    2002-01-01

    Background. The effects of the dispersed radiation described theoretically imply complex picture of interaction of the photon beam with the patient's body, as well as its dispersion on other structures. Basic theoretical laws of this phenomenon are highlighted, thus giving the opportunity to model the effect in total. Material and methods. The measurements of the absorbed dose in the air give isodose curves that show distribution of the radiation dose. For the urological procedures standard urological diagnostic methods were being used. Results. Through a large series of measuring, we got the distribution of the radiation dose in space, where urology diagnostics is being made using the X-ray. The parameters determining this picture are the most frequent ones in the total number of 20 random cases taken in General Hospital in Doboj, Bosnia and Herzegovina. Conclusions. Static dosimetric picture of the space (radiation zone) in the general sense is useful before all for organisation of the diagnostic procedures utilising ionised radiation. Obtained in any way, this picture enables an insight into the three-dimensional distribution of the dosage on the basis of which it is possible to correct the organisation of the diagnostics being performed under these conditions. The values of the radiation dosage show it is necessary to use the protecting means prescribed by law. For more frequent exposure, it would be useful to make a dynamic dosimetric picture for professional exposure and assessment of the radiation risk of these persons. (author)

  11. Simulation and interpretation of ion beam diagnostics on PBFA-II

    International Nuclear Information System (INIS)

    Mehlhorn, T.A.; Nelson, W.E.; Maenchen, J.E.; Stygar, W.A.; Ruiz, C.L.; Lockner, T.R.; Johnson, D.J.

    1988-03-01

    Ion diode and beam focusing experiments are in progress on PBFA-II working towards an ultimate goal of significant burn of an ICF pellet. Beam diagnostics on these experiments include a Thomson parabola, K/sub alpha/ x-ray pinhole cameras, filtered ion pinhole cameras, and a magnetic spectrometer. We are developing two new computer programs to simulate and interpret the data obtained from these diagnostics. VIDA is a VAX-based program that manipulates and unfolds data from digitized particle and x-ray diagnostic images. VIDA operations include: image display, background substraction, relative-to-absolute coordinate transformations, and image projection into the beam reference frame. PICDIAG allows us to study the effects of time-dependent ion focusing on the performance of ion beam diagnostics. 10 refs., 5 figs

  12. Low cut-off values increase diagnostic performance of protein S assays

    NARCIS (Netherlands)

    Mulder, Rene; ten Kate, Min Ki; Kluin-Nelemans, Hanneke C.; Mulder, Andre B.

    Conflicting data have been reported on the accuracy of protein S (PS) assays for detection of hereditary PS deficiency. In this study we assessed the diagnostic performance of two total PS antigen assays, four free PS assays and three PS activity assays in a group of 28 heterozygous carriers of

  13. Relationship between time management in construction industry and project management performance

    Science.gov (United States)

    Nasir, Najuwa; Nawi, Mohd Nasrun Mohd; Radzuan, Kamaruddin

    2016-08-01

    Nowadays, construction industry particularly in Malaysia struggle in achieving status of eminent time management for construction project. Project managers have a great responsibility to keep the project success under time of project completion. However, studies shows that delays especially in Malaysian construction industry still unresolved due to weakness in managing the project. In addition, quality of time management on construction projects is generally poor. Due to the progressively extended delays issue, time performance becomes an important subject to be explored to investigate delay factors. The method of this study is review of literature towards issues in construction industry which affecting time performance of project in general by focusing towards process involved for project management. Based on study, it was found that knowledge, commitment, cooperation are the main criteria as an overall to manage the project into a smooth process during project execution until completion. It can be concluded that, the strength between project manager and team members in these main criteria while conducting the project towards good time performance is highly needed. However, there is lack of establishment towards factors of poor time performance which strongly related with project management. Hence, this study has been conducted to establish factors of poor time performance and its relations with project management.

  14. Towards Modernizing the Characterization of Shock and Detonation Physics Performance via Novel Diagnostics and Tests

    Science.gov (United States)

    Salyer, Terry

    2017-06-01

    For the bulk of detonation performance experiments, a fairly basic set of diagnostic techniques has evolved as the standard for acquiring the necessary measurements. Gold standard techniques such as pin switches and streak cameras still produce the high-quality data required, yet much room remains for improvement with regard to ease of use, cost of fielding, breadth of data, and diagnostic versatility. Over the past several years, an alternate set of diagnostics has been under development to replace many of these traditional techniques. Pulse Correlation Reflectometry (PCR) is a capable substitute for pin switches with the advantage of obtaining orders of magnitude more data at a small fraction of the cost and fielding time. Spectrally Encoded Imaging (SEI) can replace most applications of streak camera with the advantage of imaging surfaces through a single optical fiber that are otherwise optically inaccessible. Such diagnostics advance the measurement state of the art, but even further improvements may come through revamping the standardized tests themselves such as the copper cylinder expansion test. At the core of this modernization, the aforementioned diagnostics play a significant role in revamping and improving the standard test suite for the present era. This research was performed under the auspices of the United States Department of Energy.

  15. Development of a High-Temperature Diagnostics-While-Drilling Tool

    Energy Technology Data Exchange (ETDEWEB)

    Blankenship, Douglas [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Chavira, David [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Henfling, Joseph [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Hetmaniak, Chris [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Huey, David [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Jacobson, Ron [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); King, Dennis [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Knudsen, Steve [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Mansure, A. J. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Polsky, Yarom [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)

    2009-01-01

    This report documents work performed in the second phase of the Diagnostics While-Drilling (DWD) project in which a high-temperature (HT) version of the phase 1 low-temperature (LT) proof-of-concept (POC) DWD tool was built and tested. Descriptions of the design, fabrication and field testing of the HT tool are provided.

  16. Scramjet Performance Assessment Using Water Absorption Diagnostics (U)

    Science.gov (United States)

    Cavolowsky, John A.; Loomis, Mark P.; Deiwert, George

    1995-01-01

    Simultaneous multiple path measurements of temperature and H2O concentration will be presented for the AIMHYE test entries in the NASA Ames 16-Inch Shock Tunnel. Monitoring the progress of high temperature chemical reactions that define scramjet combustor efficiencies is a task uniquely suited to nonintrusive optical diagnostics. One application strategy to overcome the many challenges and limitations of nonintrusive measurements is to use laser absorption spectroscopy coupled with optical fibers. Absorption spectroscopic techniques with rapidly tunable lasers are capable of making simultaneous measurements of mole fraction, temperature, pressure, and velocity. The scramjet water absorption diagnostic was used to measure combustor efficiency and was compared to thrust measurements using a nozzle force balance and integrated nozzle pressures to develop a direct technique for evaluating integrated scramjet performance. Tests were initially performed with a diode laser tuning over a water absorption feature at 1391.7 nm. A second diode laser later became available at a wavelength near 1343.3 nm covering an additional water absorption feature and was incorporated in the system for a two-wavelength technique. Both temperature and mole fraction can be inferred from the lineshape analysis using this approach. Additional high temperature spectroscopy research was conducted to reduce uncertainties in the scramjet application. The lasers are optical fiber coupled to ports at the combustor exit and in the nozzle region. The output from the two diode lasers were combined in a single fiber, and the resultant two-wavelength beam was subsequently split into four legs. Each leg was directed through 60 meters of optical fiber to four combustor exit locations for measurement of beam intensity after absorption by the water within the flow. Absorption results will be compared to 1D combustor analysis using RJPA and nozzle CFD computations as well as to data from a nozzle metric

  17. Diagnostic performance and color overlay pattern in shear wave elastography (SWE) for palpable breast mass.

    Science.gov (United States)

    Park, Jiyoon; Woo, Ok Hee; Shin, Hye Seon; Cho, Kyu Ran; Seo, Bo Kyoung; Kang, Eun Young

    2015-10-01

    The purpose of this study is to evaluate the diagnostic performance of SWE in palpable breast mass and to compare with color overlay pattern in SWE with conventional US and quantitative SWE for assessing palpable breast mass. SWE and conventional breast US were performed in 133 women with 156 palpable breast lesions (81 benign, 75 malignant) between August 2013 to June 2014. Either pathology or periodic imaging surveillance more than 2 years was a reference standard. Existence of previous image was blinded to performing radiologists. US BI-RADS final assessment, qualitative and quantitative SWE measurements were evaluated. Diagnostic performances of grayscale US, SWE and US combined to SWE were calculated and compared. Correlation between pattern classification and quantitative SWE was evaluated. Both color overlay pattern and quantitative SWE improved the specificity of conventional US, from 81.48% to 96.30% (p=0.0005), without improvement in sensitivity. Color overlay pattern was significantly related to all quantitative SWE parameters and malignancy rate (pbreast mass, conventional US combine to SWE improves specificity and reduces the number of biopsies that ultimately yield a benign result. Color overlay pattern classification is more quick and easy and may represent quantitative SWE measurements with similar diagnostic performances. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  18. Project management and performance management: potential transdisciplinary contributions

    Directory of Open Access Journals (Sweden)

    Gerrit van der Waldt

    2012-12-01

    Full Text Available As project management and performance management as management applications gain momentum in public sector settings, the question often arise as to if, how, and when these applications should complement each other in various policy implementation and service delivery initiatives. Answers to this question should be sought from various vantage points or perspectives. These vantage points may range from macro, meso, micro as well as theoretical-methodological perspectives. The purpose of this paper is to unlock the potential for transdisciplinary contributions between Project Management and Performance Management by focusing on the methodologies, functional areas, and practical applications of both management disciplines. It is argued that the respective methodologies and their processes should be unpacked to identify the timing or moment when each discipline could, and should, make a contribution to the success of the other. This will add value to the theoretical underpinnings and practical applications of both study domains in the public sector. The respective contributions are illustrated by means of application realities of both management practices in the South African Public Service. Keywords: project management, performance management, Public Sector applications, transdisciplinarity Disciplines: project management, performance management

  19. A portable and independent edge fluctuation diagnostic. Final performance report, March 1992--March 1993

    International Nuclear Information System (INIS)

    Tsui, H.; Wootton, A.

    1994-01-01

    A compact self contained portable probe system has been designed and developed to diagnose the edge plasma of devices of different sizes and configurations. The system measures both the mean and the fluctuation quantities of density, temperature and potential from a standardized Langmuir probe array using a fast reciprocating probe drive. It can also be used for other fluctuation diagnostics, such as magnetic probes. The data acquisition and analysis is performed on a Macintosh IIfx which provides a user-friendly environment. The results obtained by the signal processing routines are stored in a tabloid format to allow comparative studies. The resulting database is a core part of the protable signal analysis system. To date measurements have been performed on the stellarator ATF, the reversed field pinch ZT40(m), and the tokamaks TEXT, Versator, Phaedrus-T and TFTR. The data are presently being analyzed and the results collected into the database for the purpose of edge turbulence and transport studies. Existing published data are also being included. The edge database, an output of this project, will provide readily available information for other experimental groups to compare their results with, and for theoretical groups to validate (or otherwise) the predictions of their models

  20. 9 CFR 130.17 - User fees for other veterinary diagnostic laboratory tests performed at NVSL (excluding FADDL) or...

    Science.gov (United States)

    2010-01-01

    ... 9 Animals and Animal Products 1 2010-01-01 2010-01-01 false User fees for other veterinary... FEES USER FEES § 130.17 User fees for other veterinary diagnostic laboratory tests performed at NVSL (excluding FADDL) or at authorized sites. (a) User fees for veterinary diagnostics tests performed at the...

  1. 9 CFR 130.16 - User fees for veterinary diagnostic serology tests performed at NVSL (excluding FADDL) or at...

    Science.gov (United States)

    2010-01-01

    ... 9 Animals and Animal Products 1 2010-01-01 2010-01-01 false User fees for veterinary diagnostic serology tests performed at NVSL (excluding FADDL) or at authorized sites. 130.16 Section 130.16 Animals... USER FEES § 130.16 User fees for veterinary diagnostic serology tests performed at NVSL (excluding...

  2. Key performance indicators for successful simulation projects

    OpenAIRE

    Jahangirian, M; Taylor, SJE; Young, T; Robinson, S

    2016-01-01

    There are many factors that may contribute to the successful delivery of a simulation project. To provide a structured approach to assessing the impact various factors have on project success, we propose a top-down framework whereby 15 Key Performance Indicators (KPI) are developed that represent the level of successfulness of simulation projects from various perspectives. They are linked to a set of Critical Success Factors (CSF) as reported in the simulation literature. A single measure cal...

  3. Trojan Decommissioning Project Cost Performance

    International Nuclear Information System (INIS)

    Michael B. Lackey

    2000-01-01

    The Trojan nuclear plant (Trojan) was an 1160-MW(electric) four-loop pressurized water reactor located in Rainier, Oregon. The plant was permanently shut down in 1993 after ∼17 yr of commercial operation. The early plant closure was an economic decision. The key factors in the closure analysis were escalation of inspection and repair costs associated with steam generator tube cracking and the projected availability of inexpensive replacement power in the Pacific Northwest region of the United States. Since the plant closure, Portland General Electric (PGE) has been actively engaged in decommissioning. The Trojan Decommissioning Project currently has a forecast at completion of $429.7 million (all costs are in millions of 1997 dollars, unless otherwise noted). The cost performance of the Trojan Decommissioning Project to date is addressed, as well as the tools that are in place to provide cost control through completion of decommissioning

  4. Diagnostic performance of cytology for assessment of hepatic lipid content in dairy cattle.

    Science.gov (United States)

    Fry, M M; Yao, B; Ríos, C; Wong, C; Mann, S; McArt, J A A; Nydam, D V; Leal Yepes, F A; Viesselmann, L; Geick, A; Goldin, K; Jordan, A; Behling-Kelly, E

    2018-02-01

    The objective of our study was to characterize the diagnostic performance of cytology for assessing hepatic lipid content (HLC) in dairy cows by comparing microscopic evaluation of lipid vacuolation in touch imprint slide preparations of liver biopsies with quantitative measurement of triglyceride concentration ([TG]; mg/mg of wet weight) in paired biopsy samples. Our study also sought to compare the diagnostic performance of liver cytology, plasma nonesterified fatty acid concentration ([NEFA]), and plasma β-hydroxybutyrate concentration ([BHB]) derived from a measurement performed on whole blood, for assessing HLC. Chemical extraction of TG from liver tissue remains the gold standard for quantifying HLC, largely because available blood tests, although useful for detecting some types of pathology, such as increased lipid mobilization, ketosis, or hepatocellular injury, are nonspecific as to etiology. Veterinary practitioners can sample bovine liver for cytological evaluation in a fast, minimally invasive, and inexpensive manner. Thus, if highly predictive of HLC, cytology would be a practical diagnostic tool for dairy veterinarians. In our study, liver biopsy samples from Holstein cows (219 samples from 105 cows: 52 from cows 2 to 20 d prepartum, 105 from cows 0 to 10 d in milk, 62 from cows 18 to 25 d in milk) were used to prepare cytology slides and to quantify [TG] using the Folch extraction method followed by the Hantzch condensation reaction and spectrophotometric measurement. An ordinal scale (0-4) based on amount of hepatocellular cytoplasm occupied by discrete clear vacuoles was used by 3 blinded, independent observers to rank HLC in Wright-Giemsa-stained slides. Interobserver agreement in cytology scoring was good. Corresponding plasma [NEFA] and [BHB] measurements were available for 187 and 195 of the 219 samples, respectively. Liver [TG] correlated more strongly with cytology score than with NEFA or BHB, and receiver operating characteristic curve

  5. Building Performance Optimization while Empowering Occupants Toward Environmentally Sustainable Behavior through Continuous Monitoring and Diagnostics

    Science.gov (United States)

    2016-12-01

    Federal Energy Management Program FM Facility Manager GHG Green House Gases HASP Health and Safety Plan HVAC Heating Ventilation and... workplace energy efficiency enhancement by the DOD personnel. 2.1.2 ID-F Intelligent Dashboards for Facility Managers Creation of the Base Building...demonstration project. The first technology, ‘ID-F,’ targets building facility managers and allows real time diagnostics for BAS systems with features

  6. 9 CFR 130.15 - User fees for veterinary diagnostic isolation and identification tests performed at NVSL...

    Science.gov (United States)

    2010-01-01

    ... 9 Animals and Animal Products 1 2010-01-01 2010-01-01 false User fees for veterinary diagnostic isolation and identification tests performed at NVSL (excluding FADDL) or other authorized site. 130.15... AGRICULTURE USER FEES USER FEES § 130.15 User fees for veterinary diagnostic isolation and identification...

  7. Biogeochemical protocols and diagnostics for the CMIP6 Ocean Model Intercomparison Project (OMIP

    Directory of Open Access Journals (Sweden)

    J. C. Orr

    2017-06-01

    Full Text Available The Ocean Model Intercomparison Project (OMIP focuses on the physics and biogeochemistry of the ocean component of Earth system models participating in the sixth phase of the Coupled Model Intercomparison Project (CMIP6. OMIP aims to provide standard protocols and diagnostics for ocean models, while offering a forum to promote their common assessment and improvement. It also offers to compare solutions of the same ocean models when forced with reanalysis data (OMIP simulations vs. when integrated within fully coupled Earth system models (CMIP6. Here we detail simulation protocols and diagnostics for OMIP's biogeochemical and inert chemical tracers. These passive-tracer simulations will be coupled to ocean circulation models, initialized with observational data or output from a model spin-up, and forced by repeating the 1948–2009 surface fluxes of heat, fresh water, and momentum. These so-called OMIP-BGC simulations include three inert chemical tracers (CFC-11, CFC-12, SF6 and biogeochemical tracers (e.g., dissolved inorganic carbon, carbon isotopes, alkalinity, nutrients, and oxygen. Modelers will use their preferred prognostic BGC model but should follow common guidelines for gas exchange and carbonate chemistry. Simulations include both natural and total carbon tracers. The required forced simulation (omip1 will be initialized with gridded observational climatologies. An optional forced simulation (omip1-spunup will be initialized instead with BGC fields from a long model spin-up, preferably for 2000 years or more, and forced by repeating the same 62-year meteorological forcing. That optional run will also include abiotic tracers of total dissolved inorganic carbon and radiocarbon, CTabio and 14CTabio, to assess deep-ocean ventilation and distinguish the role of physics vs. biology. These simulations will be forced by observed atmospheric histories of the three inert gases and CO2 as well as carbon isotope ratios of CO2. OMIP-BGC simulation

  8. Biogeochemical Protocols and Diagnostics for the CMIP6 Ocean Model Intercomparison Project (OMIP)

    Science.gov (United States)

    Orr, James C.; Najjar, Raymond G.; Aumont, Olivier; Bopp, Laurent; Bullister, John L.; Danabasoglu, Gokhan; Doney, Scott C.; Dunne, John P.; Dutay, Jean-Claude; Graven, Heather; hide

    2017-01-01

    The Ocean Model Intercomparison Project (OMIP) focuses on the physics and biogeochemistry of the ocean component of Earth system models participating in the sixth phase of the Coupled Model Intercomparison Project (CMIP6). OMIP aims to provide standard protocols and diagnostics for ocean models, while offering a forum to promote their common assessment and improvement. It also offers to compare solutions of the same ocean models when forced with reanalysis data (OMIP simulations) vs. when integrated within fully coupled Earth system models (CMIP6). Here we detail simulation protocols and diagnostics for OMIP's biogeochemical and inert chemical tracers. These passive-tracer simulations will be coupled to ocean circulation models, initialized with observational data or output from a model spin-up, and forced by repeating the 1948-2009 surface fluxes of heat, fresh water, and momentum. These so-called OMIP-BGC simulations include three inert chemical tracers (CFC-11, CFC-12, SF [subscript] 6) and biogeochemical tracers (e.g., dissolved inorganic carbon, carbon isotopes, alkalinity, nutrients, and oxygen). Modelers will use their preferred prognostic BGC model but should follow common guidelines for gas exchange and carbonate chemistry. Simulations include both natural and total carbon tracers. The required forced simulation (omip1) will be initialized with gridded observational climatologies. An optional forced simulation (omip1-spunup) will be initialized instead with BGC fields from a long model spin-up, preferably for 2000 years or more, and forced by repeating the same 62-year meteorological forcing. That optional run will also include abiotic tracers of total dissolved inorganic carbon and radiocarbon, CTabio and 14CTabio, to assess deep-ocean ventilation and distinguish the role of physics vs. biology. These simulations will be forced by observed atmospheric histories of the three inert gases and CO2 as well as carbon isotope ratios of CO2. OMIP-BGC simulation

  9. Biogeochemical protocols and diagnostics for the CMIP6 Ocean Model Intercomparison Project (OMIP)

    Science.gov (United States)

    Orr, James C.; Najjar, Raymond G.; Aumont, Olivier; Bopp, Laurent; Bullister, John L.; Danabasoglu, Gokhan; Doney, Scott C.; Dunne, John P.; Dutay, Jean-Claude; Graven, Heather; Griffies, Stephen M.; John, Jasmin G.; Joos, Fortunat; Levin, Ingeborg; Lindsay, Keith; Matear, Richard J.; McKinley, Galen A.; Mouchet, Anne; Oschlies, Andreas; Romanou, Anastasia; Schlitzer, Reiner; Tagliabue, Alessandro; Tanhua, Toste; Yool, Andrew

    2017-06-01

    The Ocean Model Intercomparison Project (OMIP) focuses on the physics and biogeochemistry of the ocean component of Earth system models participating in the sixth phase of the Coupled Model Intercomparison Project (CMIP6). OMIP aims to provide standard protocols and diagnostics for ocean models, while offering a forum to promote their common assessment and improvement. It also offers to compare solutions of the same ocean models when forced with reanalysis data (OMIP simulations) vs. when integrated within fully coupled Earth system models (CMIP6). Here we detail simulation protocols and diagnostics for OMIP's biogeochemical and inert chemical tracers. These passive-tracer simulations will be coupled to ocean circulation models, initialized with observational data or output from a model spin-up, and forced by repeating the 1948-2009 surface fluxes of heat, fresh water, and momentum. These so-called OMIP-BGC simulations include three inert chemical tracers (CFC-11, CFC-12, SF6) and biogeochemical tracers (e.g., dissolved inorganic carbon, carbon isotopes, alkalinity, nutrients, and oxygen). Modelers will use their preferred prognostic BGC model but should follow common guidelines for gas exchange and carbonate chemistry. Simulations include both natural and total carbon tracers. The required forced simulation (omip1) will be initialized with gridded observational climatologies. An optional forced simulation (omip1-spunup) will be initialized instead with BGC fields from a long model spin-up, preferably for 2000 years or more, and forced by repeating the same 62-year meteorological forcing. That optional run will also include abiotic tracers of total dissolved inorganic carbon and radiocarbon, CTabio and 14CTabio, to assess deep-ocean ventilation and distinguish the role of physics vs. biology. These simulations will be forced by observed atmospheric histories of the three inert gases and CO2 as well as carbon isotope ratios of CO2. OMIP-BGC simulation protocols are

  10. Diagnostic performance of qualitative shear-wave elastography according to different color map opacities for breast masses.

    Science.gov (United States)

    Kim, Hana; Youk, Ji Hyun; Gweon, Hye Mi; Kim, Jeong-Ah; Son, Eun Ju

    2013-08-01

    To compare the diagnostic performance of qualitative shear-wave elastography (SWE) according to three different color map opacities for breast masses 101 patients aged 21-77 years with 113 breast masses underwent B-mode US and SWE under three different color map opacities (50%, 19% and 100%) before biopsy or surgery. Following SWE features were reviewed: visual pattern classification (pattern 1-4), color homogeneity (Ehomo) and six-point color score of maximum elasticity (Ecol). Combined with B-mode US and SWE, the likelihood of malignancy (LOM) was also scored. The area under the curve (AUC) was obtained by ROC curve analysis to assess the diagnostic performance under each color opacity. A visual color pattern, Ehomo, Ecol and LOM scoring were significantly different between benign and malignant lesions under all color opacities (Pbreast lesion under all color opacities. The difference in color map opacity did not significantly influence diagnostic performance of SWE. Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.

  11. Diagnostic performance of Tc-99m HMPAO SPECT for early and late onset Alzheimer's disease. A clinical evaluation of linearization correction

    International Nuclear Information System (INIS)

    Mitsumoto, Tatsuya; Sakaguchi, Yuichi; Morishita, Junji; Sasaki, Masayuki; Ohya, Nobuyoshi; Abe, Koichiro; Ichimiya, Atsushi; Kiyota, Aya

    2009-01-01

    This study examined the influence of linearization correction (LC) on brain perfusion single-photon emission computed tomography (SPECT) for the diagnosis of Alzheimer's disease (AD). The early onset group (<65 years old) consisted of 10 patients with AD, and the late onset group (≥65 years old) of 13 patients with AD. Age-matched controls included seven younger and seven older normal volunteers. Tc-99m hexamethyl propyleneamine oxine (HMPAO) SPECT images were reconstructed with or without LC [LC (+) or LC (-)] and a statistical analysis was performed using a three-dimensional stereotactic surface projection (3D-SSP). In addition, a fully automatic diagnostic system was developed, which calculated the proportion of the number of abnormal pixels in the superior and inferior parietal lobule, as well as in the precuneus and posterior cingulate gyrus. The areas under the receiver-operating characteristic curve (AUCs) of the early onset group for conventional axial SPECT images, SPECT+3D-SSP images and the fully automatic diagnostic system were 0.71, 0.88, and 0.92 in LC (-) and 0.67, 0.85, and 0.91 in LC (+), respectively. The AUCs of the late onset group were 0.50, 0.61, and 0.79 in LC (-) and 0.49, 0.67, and 0.85 in LC (+), respectively. LC on Tc-99m HMPAO SPECT did not significantly influence the diagnostic performance for differentiating between AD and normal controls in either early or late onset AD. Further examination with individuals suffering from very mild dementia is, therefore, expected to elucidate the effect of LC on minimally hypoperfused areas. (author)

  12. The Effects of Fatigue From Overnight Shifts on Radiology Search Patterns and Diagnostic Performance.

    Science.gov (United States)

    Hanna, Tarek N; Zygmont, Matthew E; Peterson, Ryan; Theriot, David; Shekhani, Haris; Johnson, Jamlik-Omari; Krupinski, Elizabeth A

    2018-01-20

    The aim of this study was to assess the effect of overnight shifts (ONS) on radiologist fatigue, visual search pattern, and diagnostic performance. This experimental study was approved by the institutional review board. Twelve radiologists (five faculty members and seven residents) each completed two sessions: one during a normal workday ("not fatigued") and another in the morning after an ONS ("fatigued"). Each radiologist completed the Swedish Occupational Fatigue Inventory. During each session, radiologists viewed 20 bone radiographs consisting of normal and abnormal findings. Viewing time, diagnostic confidence, and eye-tracking data were recorded. Swedish Occupational Fatigue Inventory results demonstrated worsening in all five variables (lack of energy, physical exertion, physical discomfort, lack of motivation, and sleepiness) after ONS (P radiologists were more fatigued with worse diagnostic performance, a 45% increase in view time per case, a 60% increase in total gaze fixations, and a 34% increase in time to fixate on the fracture. The effects of fatigue were more pronounced in residents. Copyright © 2017 American College of Radiology. Published by Elsevier Inc. All rights reserved.

  13. Fuzzy based method for project planning of the infrastructure design for the diagnostic in ITER

    International Nuclear Information System (INIS)

    Piros, Attila; Veres, Gábor

    2013-01-01

    The long-term design projects need special preparation before the start of the execution. This preparation usually includes the drawing of the network diagram for the whole procedure. This diagram includes the time estimation of the individual subtasks and gives us information about the predicted dates of the milestones. The calculated critical path in this network characterizes a specific design project concerning to its duration very well. Several methods are available to support this step of preparation. This paper describes a new method to map the structure of the design process and clarify the milestones and predict the dates of these milestones. The method is based on the PERT (Project Evaluation and Review Technique) network but as a novelty it applies fuzzy logic to find out the concerning times in this graph. With the application of the fuzzy logic the handling of the different kinds of design uncertainties becomes feasible. Many kinds of design uncertainties exist from the possible electric blackout up to the illness of an engineer. In many cases these uncertainties are related with human errors and described with linguistic expressions. The fuzzy logic enables to transform these ambiguous expressions into numeric values for further mathematical evaluation. The method is introduced in the planning of the design project of the infrastructure for the diagnostic systems of ITER. The method not only helps the project in the planning phase, but it will be a powerful tool in mathematical modeling and monitoring of the project execution

  14. Fuzzy based method for project planning of the infrastructure design for the diagnostic in ITER

    Energy Technology Data Exchange (ETDEWEB)

    Piros, Attila, E-mail: attila.piros@gt3.bme.hu [Department of Machine and Product Design, Budapest University of Technology and Economics, Budapest (Hungary); Veres, Gábor [Department of Plasma Physics, Wigner Research Centre for Physics, Hungarian Academy of Sciences, Budapest (Hungary)

    2013-10-15

    The long-term design projects need special preparation before the start of the execution. This preparation usually includes the drawing of the network diagram for the whole procedure. This diagram includes the time estimation of the individual subtasks and gives us information about the predicted dates of the milestones. The calculated critical path in this network characterizes a specific design project concerning to its duration very well. Several methods are available to support this step of preparation. This paper describes a new method to map the structure of the design process and clarify the milestones and predict the dates of these milestones. The method is based on the PERT (Project Evaluation and Review Technique) network but as a novelty it applies fuzzy logic to find out the concerning times in this graph. With the application of the fuzzy logic the handling of the different kinds of design uncertainties becomes feasible. Many kinds of design uncertainties exist from the possible electric blackout up to the illness of an engineer. In many cases these uncertainties are related with human errors and described with linguistic expressions. The fuzzy logic enables to transform these ambiguous expressions into numeric values for further mathematical evaluation. The method is introduced in the planning of the design project of the infrastructure for the diagnostic systems of ITER. The method not only helps the project in the planning phase, but it will be a powerful tool in mathematical modeling and monitoring of the project execution.

  15. Exercise echocardiography or exercise SPECT imaging? - A meta-analysis of diagnostic test performance

    NARCIS (Netherlands)

    Fleischmann, KE; Hunink, MGM; Kuntz, KM; Douglas, PS

    1998-01-01

    Context.-Cardiac imaging has advanced rapidly, providing clinicians with several choices for evaluating patients with suspected coronary artery disease, but few studies compare modalities directly. .-To review the contemporary literature and to compare the diagnostic performance of exercise

  16. Systematic reviews of diagnostic tests in endocrinology: an audit of methods, reporting, and performance.

    Science.gov (United States)

    Spencer-Bonilla, Gabriela; Singh Ospina, Naykky; Rodriguez-Gutierrez, Rene; Brito, Juan P; Iñiguez-Ariza, Nicole; Tamhane, Shrikant; Erwin, Patricia J; Murad, M Hassan; Montori, Victor M

    2017-07-01

    Systematic reviews provide clinicians and policymakers estimates of diagnostic test accuracy and their usefulness in clinical practice. We identified all available systematic reviews of diagnosis in endocrinology, summarized the diagnostic accuracy of the tests included, and assessed the credibility and clinical usefulness of the methods and reporting. We searched Ovid MEDLINE, EMBASE, and Cochrane CENTRAL from inception to December 2015 for systematic reviews and meta-analyses reporting accuracy measures of diagnostic tests in endocrinology. Experienced reviewers independently screened for eligible studies and collected data. We summarized the results, methods, and reporting of the reviews. We performed subgroup analyses to categorize diagnostic tests as most useful based on their accuracy. We identified 84 systematic reviews; half of the tests included were classified as helpful when positive, one-fourth as helpful when negative. Most authors adequately reported how studies were identified and selected and how their trustworthiness (risk of bias) was judged. Only one in three reviews, however, reported an overall judgment about trustworthiness and one in five reported using adequate meta-analytic methods. One in four reported contacting authors for further information and about half included only patients with diagnostic uncertainty. Up to half of the diagnostic endocrine tests in which the likelihood ratio was calculated or provided are likely to be helpful in practice when positive as are one-quarter when negative. Most diagnostic systematic reviews in endocrine lack methodological rigor, protection against bias, and offer limited credibility. Substantial efforts, therefore, seem necessary to improve the quality of diagnostic systematic reviews in endocrinology.

  17. Cable Diagnostic Focused Initiative

    Energy Technology Data Exchange (ETDEWEB)

    Hartlein, R.A.; Hampton, R.N.

    2010-12-30

    This report summarizes an extensive effort made to understand how to effectively use the various diagnostic technologies to establish the condition of medium voltage underground cable circuits. These circuits make up an extensive portion of the electric delivery infrastructure in the United States. Much of this infrastructure is old and experiencing unacceptable failure rates. By deploying efficient diagnostic testing programs, electric utilities can replace or repair circuits that are about to fail, providing an optimal approach to improving electric system reliability. This is an intrinsically complex topic. Underground cable systems are not homogeneous. Cable circuits often contain multiple branches with different cable designs and a range of insulation materials. In addition, each insulation material ages differently as a function of time, temperature and operating environment. To complicate matters further, there are a wide variety of diagnostic technologies available for assessing the condition of cable circuits with a diversity of claims about the effectiveness of each approach. As a result, the benefits of deploying cable diagnostic testing programs have been difficult to establish, leading many utilities to avoid the their use altogether. This project was designed to help address these issues. The information provided is the result of a collaborative effort between Georgia Tech NEETRAC staff, Georgia Tech academic faculty, electric utility industry participants, as well as cable system diagnostic testing service providers and test equipment providers. Report topics include: •How cable systems age and fail, •The various technologies available for detecting potential failure sites, •The advantages and disadvantages of different diagnostic technologies, •Different approaches for utilities to employ cable system diagnostics. The primary deliverables of this project are this report, a Cable Diagnostic Handbook (a subset of this report) and an online

  18. THE HARMONIZATION AND OPTIMIZATION OF DIAGNOSTIC METHODS FOR A BELT CONVEYOR

    Directory of Open Access Journals (Sweden)

    František HELEBRANT

    2012-04-01

    Full Text Available The final aim of the project MPO FR‐T11/537 called “The Complex Diagnostic System for the Belt Transport” is a single part custom manufacturing and sale of complex diagnostic system for belt transportation and related services. The output of the project is a prototype of a diagnostic system on a model belt conveyor with prepared and certified diagnostic services and methods including their measurements and other supportive tools. The article will introduce the present state of the solution for the given grant project, especially in the field of suggested work on the diagnostic and supportive methods and other measurements.

  19. [Diagnostic and organizational error in head injuries].

    Science.gov (United States)

    Zaba, Czesław; Zaba, Zbigniew; Swiderski, Paweł; Lorkiewicz-Muszyíska, Dorota

    2009-01-01

    The study aimed at presenting a case of a diagnostic and organizational error involving lack of detection of foreign body presence in the soft tissues of the head. Head radiograms in two projections clearly demonstrated foreign bodies that resembled in shape flattened bullets, which could not have been missed upon evaluation of the X-rays. On the other hand, description of the radiograms entered by the attending physicians to the patient's medical record indicated an absence of traumatic injuries or foreign bodies. In the opinion of the authors, the case in question involved a diagnostic error: the doctors failed to detect the presence of foreign bodies in the head. The organizational error involved the failure of radiogram evaluation performed by a radiologist.

  20. Substantia nigra fractional anisotropy is not a diagnostic biomarker of Parkinson's disease: A diagnostic performance study and meta-analysis

    Energy Technology Data Exchange (ETDEWEB)

    Hirata, Fabiana C.C.; Vieira, Gilson; Lucato, Leandro T.; Leite, Claudia C.; Pastorello, Bruno F.; Otaduy, Maria C.G.; Chaim, Khallil T.; Campanholo, Kenia R. [University of Sao Paulo, LIM-44, Department of Radiology, Sao Paulo, SP (Brazil); Sato, Joao R. [University of Sao Paulo, LIM-44, Department of Radiology, Sao Paulo, SP (Brazil); Universidade Federal do ABC, Center of Mathematics, Computation and Cognition, Santo Andre (Brazil); Bor-Seng-Shu, Edson; Novaes, Natalia P. [Hospital Israelita Albert Einstein, Sao Paulo (Brazil); University of Sao Paulo, Department of Neurology, Sao Paulo (Brazil); Magalhaes Melo, Luciano; Goncalves, Marcia R.; Reis Barbosa, Egberto [University of Sao Paulo, Department of Neurology, Sao Paulo (Brazil); Pereira do Nascimento, Felipe Barjud; Amaro, Edson [University of Sao Paulo, LIM-44, Department of Radiology, Sao Paulo, SP (Brazil); Hospital Israelita Albert Einstein, Sao Paulo (Brazil); Jacobsen Teixeira, Manoel [University of Sao Paulo, Department of Neurosurgery, Sao Paulo (Brazil); Cardoso, Ellison Fernando [University of Sao Paulo, LIM-44, Department of Radiology, Sao Paulo, SP (Brazil); Hospital Israelita Albert Einstein, Sao Paulo (Brazil); Institute of Mathematics and Statistics University of Sao Paulo (IME-USP), Sao Paulo (Brazil)

    2017-06-15

    Our goal was to estimate the diagnostic accuracy of substantia nigra fractional anisotropy (SN-FA) for Parkinson's disease (PD) diagnosis in a sample similar to the clinical setting, including patients with essential tremor (ET) and healthy controls (HC). We also performed a systematic review and meta-analysis to estimate mean change in SN-FA induced by PD and its diagnostic accuracy. Our sample consisted of 135 subjects: 72 PD, 21 ET and 42 HC. To address inter-scanner variability, two 3.0-T MRI scans were performed. MRI results of this sample were pooled into a meta-analysis that included 1,432 subjects (806 PD and 626 HC). A bivariate model was used to evaluate diagnostic accuracy measures. In our sample, we did not observe a significant effect of disease on SN-FA and it was uninformative for diagnosis. The results of the meta-analysis estimated a 0.03 decrease in mean SN-FA in PD relative to HC (CI: 0.01-0.05). However, the discriminatory capability of SN-FA to diagnose PD was low: pooled sensitivity and specificity were 72 % (CI: 68-75) and 63 % (CI: 58-70), respectively. There was high heterogeneity between studies (I{sup 2} = 91.9 %). SN-FA cannot be used as an isolated measure to diagnose PD. (orig.)

  1. All-polymer biosensor for label-free point of care diagnostics

    DEFF Research Database (Denmark)

    Dapra, Johannes

    2013-01-01

    without the need for a specialised laboratory. Other fields of application are for example health care projects in developing countries where access to modern high-throughput facilities is often impossible or sectors not related to the medical field, like environmental monitoring or food safety. The aim......Personalised medicine and diagnostics is a rapidly growing field of research and general interest. Important tools for individual patient care are so called point-of-care devices. These typically simple and inexpensive instruments allow the untrained user to perform simple diagnostic analyses...... of this PhD project was to develop a modular platform based on electrochemical impedimetric sensing. This device can easily be modified by changing the biological receptors and therefore offers a broad range of possible applications. To keep the costs and the environmental footprint low the entire biosensor...

  2. Diagnostic Performance of Narrow Band Imaging for Laryngeal Cancer: A Systematic Review and Meta-analysis.

    Science.gov (United States)

    Sun, Changling; Han, Xue; Li, Xiaoying; Zhang, Yayun; Du, Xiaodong

    2017-04-01

    Objective To evaluate the performance of narrow band imaging (NBI) for the diagnosis of laryngeal cancer and to compare the diagnostic value of NBI with that of white light endoscopy. Data Sources PubMed, Embase, Cochrane Library, and CNKI databases. Review Methods Data analyses were performed with Meta-DiSc. The updated Quality Assessment of Diagnostic Accuracy Studies-2 tool was used to assess study quality and potential bias. Publication bias was assessed with the Deeks's asymmetry test. The protocol used in this article has been published on PROSPERO and is in accordance with the PRISMA checklist. The registry number for this study is CRD42015025866. Results Six studies including 716 lesions were included in this meta-analysis. The pooled sensitivity, specificity, and diagnostic odds ratio for the NBI diagnosis of laryngeal cancer were 0.94 (95% confidence interval [95% CI]: 0.91-0.96), 0.89 (95% CI: 0.85-0.92), and 142.12 (95% CI: 46.42-435.15), respectively, and the area under receiver operating characteristics curve was 0.97. Among the 6 studies, 3 evaluated the diagnostic value of white light endoscopy, with a sensitivity of 0.81 (95% CI: 0.76-0.86), a specificity of 0.92 (95% CI: 0.88-0.95), and a diagnostic odds ratio of 33.82 (95% CI: 14.76-77.49). The evaluation of heterogeneity, calculated per the diagnostic odds ratio, gave an I 2 of 66%. No marked publication bias ( P = .84) was detected in this meta-analysis. Conclusion The sensitivity of NBI is superior to white light endoscopy, and the potential value of NBI needs to be validated in future studies.

  3. Adding Shareholder Value through Project Performance Measurement, Monitoring & Control

    NARCIS (Netherlands)

    M.M. Akalu; J.R. Turner (Rodney)

    2002-01-01

    textabstractWe present the various views and methods of measuring and controlling project performance, and factors affecting a project. The review indicates that there is a shift in the type and understanding of factors of project success or failure. However, the presence of various measurement

  4. Diagnostic performance of CT and MRI on the detection of symptomatic intracranial dural arteriovenous fistula: a meta-analysis with indirect comparison

    Energy Technology Data Exchange (ETDEWEB)

    Lin, Yen-Heng [National Taiwan University, Institute of Epidemiology and Preventive Medicine, Taipei (China); National Taiwan University Hospital in Taipei and Yuan-Lin Branch, Department of Medical Imaging and Radiology, Hospital and Medical College, Taipei (China); Lin, Hsien-Ho [National Taiwan University, Institute of Epidemiology and Preventive Medicine, Taipei (China); Liu, Hon-Man; Lee, Chung-Wei; Chen, Ya-Fang [National Taiwan University Hospital in Taipei and Yuan-Lin Branch, Department of Medical Imaging and Radiology, Hospital and Medical College, Taipei (China)

    2016-08-15

    This study aims to review the diagnostic performance of computed tomography (CT) and magnetic resonance imaging (MRI) in symptomatic dural arteriovenous fistula (DAVF). EMBASE, PubMed, and Cochrane Library were searched until April 2015 for studies which compared CT, MRI, or both with angiography for the detection of DAVF. The diagnostic performances of MRI and CT were indirectly compared using modality as a covariate in the analysis. Thirteen studies met our inclusion criteria. MRI had a sensitivity of 0.90 (95 % confidence interval (CI) = 0.83-0.94) and specificity of 0.94 (95 % CI = 0.90-0.96). CT had a sensitivity of 0.80 (95 % CI = 0.62-0.90) and specificity of 0.87 (95 % CI = 0.74-0.94). MRI showed better diagnostic performance than CT (p = 0.02). Contrast medium use and time-resolved MR angiography did not improve MRI diagnostic performance (p = 0.31 and 0.44, respectively). Both CT and MRI had good diagnostic performance. MRI was better than CT on the detection of symptomatic intracranial dural arteriovenous fistula in the indirect comparison. (orig.)

  5. Prototype road weather performance management tool : project report : draft report.

    Science.gov (United States)

    2016-09-30

    This report is the Project Report for the Road Weather Performance Management (RW-PM) Tool developed for the project on Development and Demonstration of a Prototype Road Weather Performance Management Application that Uses Connected Vehicle Data (RW-...

  6. Use of safety management practices for improving project performance.

    Science.gov (United States)

    Cheng, Eddie W L; Kelly, Stephen; Ryan, Neal

    2015-01-01

    Although site safety has long been a key research topic in the construction field, there is a lack of literature studying safety management practices (SMPs). The current research, therefore, aims to test the effect of SMPs on project performance. An empirical study was conducted in Hong Kong and the data collected were analysed with multiple regression analysis. Results suggest that 3 of the 15 SMPs, which were 'safety committee at project/site level', 'written safety policy', and 'safety training scheme' explained the variance in project performance significantly. Discussion about the impact of these three SMPs on construction was provided. Assuring safe construction should be an integral part of a construction project plan.

  7. Construction Project Performance Improvement through Radio Frequency Identification Technology Application on a Project Supply Chain

    Science.gov (United States)

    Wang, Heng

    2017-01-01

    Construction project productivity typically lags other industries and it has been the focus of numerous studies in order to improve the project performance. This research investigated the application of Radio Frequency Identification (RFID) technology on construction projects' supply chain and determined that RFID technology can improve the…

  8. Plasma diagnostic reflectometry

    International Nuclear Information System (INIS)

    Cohen, B.I.; Afeyan, B.B.; Garrison, J.C.; Kaiser, T.B.; Luhmann, N.C. Jr.; Domier, C.W.; Chou, A.E.; Baang, S.

    1996-01-01

    Theoretical and experimental studies of plasma diagnostic reflectometry have been undertaken as a collaborative research project between the Lawrence Livermore National Laboratory (LLNL) and the University of California Department of Applied Science Plasma Diagnostics Group under the auspices of the Laboratory Directed Research and Development Program at LLNL. Theoretical analyses have explored the basic principles of reflectometry to understand its limitations, to address specific gaps in the understanding of reflectometry measurements in laboratory experiments, and to explore extensions of reflectometry such as ultra-short-pulse reflectometry. The theory has supported basic laboratory reflectometry experiments where reflectometry measurements can be corroborated by independent diagnostic measurements

  9. An Evaluation of the Performance Diagnostic Checklist-Human Services to Assess an Employee Performance Problem in a Center-Based Autism Treatment Facility

    Science.gov (United States)

    Ditzian, Kyle; Wilder, David A.; King, Allison; Tanz, Jeanine

    2015-01-01

    The Performance Diagnostic Checklist-Human Services (PDC-HS) is an informant-based tool designed to assess the environmental variables that contribute to poor employee performance in human services settings. We administered the PDC-HS to 3 supervisors to assess the variables that contributed to poor performance by 4 staff members when securing…

  10. The diagnostic performance of imaging methods in ARVC using the 2010 Task Force criteria

    DEFF Research Database (Denmark)

    Borgquist, Rasmus; Haugaa, Kristina H; Gilljam, Thomas

    2014-01-01

    , fractional area shortening 31 ± 9 vs. 39 ± 9% (P performance was low; sensitivity 50% and specificity 70%, positive predictive value 80% and negative predictive value 37...... evaluation of subtle structural changes in the right ventricle may be unreliable, and the diagnostic performance of CMR compared with echocardiography should be reflected in the guidelines....

  11. Diagnostic Performance of Ultrasonography for Pediatric Appendicitis: A Night and Day Difference?

    Science.gov (United States)

    Mangona, Kate Louise M; Guillerman, R Paul; Mangona, Victor S; Carpenter, Jennifer; Zhang, Wei; Lopez, Monica; Orth, Robert C

    2017-12-01

    For imaging pediatric appendicitis, ultrasonography (US) is preferred because of its lack of ionizing radiation, but is limited by operator dependence. This study investigates the US diagnostic performance during night shifts covered by radiology trainees compared to day shifts covered by attending radiologists. Appy-Scores (1 = completely visualized normal appendix; 2 = partially visualized normal appendix; 3 = nonvisualized appendix with no inflammatory changes in the expected region of the appendix; 4 = equivocal; 5a = nonperforated appendicitis; 5b = perforated appendicitis) from 2935 US examinations (2161:774, day-to-night) from July 2013 to 2014 were correlated with the intraoperative diagnoses and the clinical follow-up. The diagnostic performance of trainees and attendings was compared with Fisher exact test. Interobserver agreement was measured by Cohen kappa coefficient. Appendicitis prevalence was 25.3% (day) and 22.5% (night). Sensitivity, specificity, accuracy, negative predictive value, and positive predictive vale were 94.0%, 93.7%, 93.8%, 97.9%, and 83.4% during the day and 92.0%, 91.2%, 91.3%, 97.5%, and 75.2% at night. Specificity (P = .048) and positive predictive value (P = .011) differed, with more false positives at night (7%) than during the day (4.7%). Trainee and attending agreement was high (k = 0.995), with Appy-Scores of 1, 4, and 5a most frequently discordant. US has a high diagnostic performance and interobserver agreement for pediatric appendicitis when interpreted by radiology trainees during night shifts or attending radiologists during day shifts. However, lower specificity and positive predictive value at night warrants a thorough trainee education to avoid false-positive examinations. Published by Elsevier Inc.

  12. Diagnostic performances of serum liver enzymes and cytokines in non-alcoholic fatty liver disease

    Directory of Open Access Journals (Sweden)

    Hakan Turkon

    2015-03-01

    Full Text Available Objective:Non-alcoholic fatty liver disease (NAFLD is affecting people worldwide with increasing prevalence. Non-invasive tests are required for both diagnosis and staging of the disease. We aimed to evaluate diagnostic accuracy of routine liver enzymes and cytokines in NAFLD. Methods:A total of 88 cases, aged between 20 and 62 years, were included in the study. Serum ALT, AST, GGT, triglyceride, TNF-alpha, IL-6 and IL-8 were measured in 40 patients with NAFLD and in 48 healthy control patients with similar BMI and demographic characteristics. Diagnostic performances of serum biomarkers for diagnosis of NAFLD were evaluated with ROC analysis. Results:ALT and AST showed good diagnostic performance in predicting patients with NAFLD in the overall group (AUC=0.817; 95% CI[0.721-0.913], AUC=0.815;95% CI[0.718-0.911] respectively but in obese subjects ALT and AST showed poor performance (AUC=0.659;95% CI[0.478-0.841], AUC=0.680; 95% CI[0.498-0.861] respectively. Among cytokines TNF-alpha showed best performance in the diagnosis of NAFLD in both overall group and obese subjects (AUC=0.892; 95% CI[0.824- 0.959], AUC=0.858; 95% CI[0.739-0.977] respectively. The optimal cut off value for TNF-alpha was 10.65pg/ml with a sensitivity of 75% and a specificity of 93% in the overall group. IL-6 and IL-8 showed poor performance. Conclusion: TNF-alpha may be a good parameter for predicting patients with NAFLD. J Clin Exp Invest 2015;6 (1: 16-20

  13. Quantitative evaluation of visual detection performance in medicine: ROC analysis and determination of diagnostic benefit

    International Nuclear Information System (INIS)

    Metz, C.E.; Starr, S.J.; Lusted, L.B.

    1976-01-01

    An ROC curve provides an empirical description of the trade-offs which are possible among the various types of correct and incorrect decisions as the human decision-maker varies one or more confidence thresholds. Conventional ROC curves measured in simple decision-making situations can, in some cases, be used to predict human decision performance in more complex situations. By considering both the consequences of the various types of diagnostic decisions and the overhead cost of a diagnostic study, one can use the ROC curve to evaluate the diagnostic usefulness of a study in any particular clinical context. Since the ROC curve describes the possible relationships among the probabilities of the various types of correct and incorrect decisions, it plays a central role in optimizing diagnostic strategies using the general techniques of decision analysis. Applications in radiographic image evaluation are described

  14. Photovoltaic test and demonstration project. [residential energy program

    Science.gov (United States)

    Forestieri, A. F.; Brandhorst, H. W., Jr.; Deyo, J. N.

    1976-01-01

    The considered project consists of three subprojects related to applications, device performance and diagnostics, and endurance testing. The objectives of the applications subproject include the determination of the operating characteristics for a variety of photovoltaic conversion systems. A system test facility is being constructed in this connection and a prototype residence experiment is to be conducted. Market demand for solar cells is to be stimulated by demonstrating suitability of solar cells for specific near-term applications. Activities conducted in connection with device performance studies and diagnostics are also discussed along with developments in the area of endurance testing.

  15. High performance multichannel photonic biochip sensors for future point of care diagnostics: an overview on two EU-sponsored projects

    Science.gov (United States)

    Giannone, Domenico; Kazmierczak, Andrzej; Dortu, Fabian; Vivien, Laurent; Sohlström, Hans

    2010-04-01

    We present here research work on two optical biosensors which have been developed within two separate European projects (6th and 7th EU Framework Programmes). The biosensors are based on the idea of a disposable biochip, integrating photonics and microfluidics, optically interrogated by a multichannel interrogation platform. The objective is to develop versatile tools, suitable for performing screening tests at Point of Care or for example, at schools or in the field. The two projects explore different options in terms of optical design and different materials. While SABIO used Si3N4/SiO2 ring resonators structures, P3SENS aims at the use of photonic crystal devices based on polymers, potentially a much more economical option. We discuss both approaches to show how they enable high sensitivity and multiple channel detection. The medium term objective is to develop a new detection system that has low cost and is portable but at the same time offering high sensitivity, selectivity and multiparametric detection from a sample containing various components (e.g. blood, serum, saliva, etc.). Most biological sensing devices already present on the market suffer from limitations in multichannel operation capability (either the detection of multiple analytes indicating a given pathology or the simultaneous detection of multiple pathologies). In other words, the number of different analytes that can be detected on a single chip is very limited. This limitation is a main issue addressed by the two projects. The excessive cost per test of conventional bio sensing devices is a second issue that is addressed.

  16. Diagnostic performance of combined single photon emission computed tomographic scintimammography and ultrasonography based on computer-aided diagnosis for breast cancer

    International Nuclear Information System (INIS)

    Hwang, Kyung Hoon; Choi, Duck Joo; Choe, Won Sick; Lee, Jun Gu; Kim, Jong Hyo; Lee, Hyung Ji; Om, Kyong Sik; Lee, Byeong Il

    2007-01-01

    We investigated whether the diagnostic performance of SPECT scintimammography (SMM) can be improved by adding computer-aided diagnosis (CAD) of ultrasonography (US). We reviewed breast SPECT SMM images and corresponding US images from 40 patients with breast masses (21 malignant and 19 benign tumors.) The quantitative data of SPECT SMM were obtained as the uptake ratio of lesion to contralateral normal breast. The morphologic features of the breast lesions on US were extracted and quantitated using the automated CAD software program. The diagnostic performance of SPECT SMM and CAD of US alone was determined using receiver operating characteristic (ROC) curve analysis. The best discriminating parameter (D-value) combining SPECT SMM and the CAD of US was created. The sensitivity, specificity and accuracy of combined two diagnostic modalities were compared to those of a single one. Both SPECT SMM and CAD of US showed a relatively good diagnostic performance (area under curve=0.846 and 0.831, respectively). Combining the results of SPECT SMM and CAD of US resulted in improved diagnostic performance (area under curve=0.860), but there was no statistical difference in sensitivity, specificity and accuracy between the combined method and a single modality. It seems that combining the results of SPECT SMM and CAD of breast US do not significantly improve the diagnostic performance for diagnosis of breast cancer, compared with that of SPECT SMM alone. However, SPECT SMM and CAD of US may complement each other in differential diagnosis of breast cancer

  17. Procuring complex performance:case: public infrastructure projects

    OpenAIRE

    Leppänen, T. (Tero)

    2015-01-01

    Abstract This research studies procuring complex performance (PCP) in the case of public infrastructure projects. Focus of the research is on the interface between public clients and private sector contractors. Purpose of this research is to find out what are the main challenges of different project delivery methods according to literature (RQ1) and what are the practical challenges of public procurement (RQ2). As an end re...

  18. Quality criteria in diagnostic radiology of the skeleton

    International Nuclear Information System (INIS)

    Freyschmidt, J.

    1985-01-01

    Conventional diagnostic radiology continues to represent the basic technique in skeleton diagnostics and results in decisive diagnoses in more than 80% of all cases. Compared with other examination methods, it is cheap and relatively easy to perform; however, it makes high demands on the physician's clinical and technical expertise. Compared with computerized tomography, conventional radiography has the advantage of decades of experience and of being cheaper by far. The author thinks the following quality criteria to be important in diagnostic radiology of the skeleton: roentgenological examination of one or several skeleton regions in keeping with the clinical issue concerned, accurate visualization of the object in a typical and reproducible projection, radiation quality matched to the dimension of the object, matched mean optical density, visualization of soft tissue near to bones and joints, and radiation dose in keeping with the clinical issue concerned. (orig./MG) [de

  19. Cooperative research and development for artificial intelligence based reactor diagnostic system

    International Nuclear Information System (INIS)

    Reifman, J.; Wei, T.Y.C.; Abboud, R.G.; Chasensky, T.M.

    1994-01-01

    Artificial Intelligence (AI) techniques in the form of knowledge-based Expert Systems (ESs) have been proposed to provide on-line decision-making support for plant operators during both normal and emergency conditions. However, in spite of the great interest in these advanced techniques, their application in the diagnosis of large-scale processes has not yet reached its full potential because of limitations of the knowledge base. These limitations include problems with knowledge acquisition and the use of an event-oriented approach for process diagnosis. To investigate the capabilities of this two-level hierarchical knowledge structure, Commonwealth Research Corporation (CRC) and Argonne National Laboratory (ANL)are collaborating on a DOE-sponsored Cooperative Research and Development Agreement (CRADA) project to perform feasibility studies on the proposed diagnostic system. Investigations are being performed in the construction of a physics-based plant level process diagnostic ES and the characterization of component-level fault project is to develop a computer-based system using this Al approach to assist process plant operators during off-normal plant conditions. The proposed computer-based system will use T-H signals complemented by other non-T-H signals available in the data stream to provide the process operator with the component which most likely caused the observed process disturbance. To demonstrate the scale-up feasibility of the proposed diagnostic system it is being developed for use with the Chemical Volume Control System (CVCS) of a nuclear power plant. This is an ongoing multi-year project and the remainder of this paper presents a mid-term status report

  20. Overview of radiation protection programme in nuclear medicine facility for diagnostic procedures

    International Nuclear Information System (INIS)

    Ahmed, Ezzeldein Mohammed Nour Mohammed

    2015-02-01

    This project was conducted to review Radiation Protection Program in Nuclear Medicine facility for diagnostic procedures which will provide guide for meeting the standard and regulatory requirements in diagnostic nuclear medicine. The main objective of this project is to keep dose to staff, patient and public as low as reasonably achievable (ALARA). The specific objectives were to review the Radiation Protection Program (RPP) in diagnostic nuclear medicine and to make some recommendation for improving the level of radiation protection in diagnostic nuclear medicine that will help to control normal exposure and prevent or mitigate potential exposure. The methodology used is review of various documents. The review showed that if the Radiation Protection Program is inadequate it leads to unjustified exposure to radiation. Finally, this study stated some recommendations that if implemented could improve the level of radiation protection in nuclear medicine department. One of the most important recommendations is that a qualified Radiation Protection Officer (RPO) should be appointed to lay down and oversee a radiation protection in the nuclear medicine department. The RPO must be given the full authority and the adequate time to enable him to perform his duties effectively. (au)

  1. Managing teams performing complex innovation projects

    NARCIS (Netherlands)

    Oeij, P.R.A.; Vroome, E.M.M. de; Dhondt, S.; Gaspersz, J.B.R.

    2012-01-01

    Complexity of projects is hotly debated and a factor which affects innovativeness of team performance. Much attention in the past is paid to technical complexity and many issues are related to natural and physical sciences. A growing awareness of the importance of socio-organisational issues is

  2. National radiology standards in X-ray diagnostic incl. interventional radiology

    International Nuclear Information System (INIS)

    Valek, V.; Kratochvil, P.

    2005-01-01

    In 2004 the Ministry of Health care started within the frame of the program for support of quality in health care a project consisting of 4 separate tasks: creating of standards for medical irradiation in radiodiagnostics, in radiotherapy , in nuclear medicine and creating of standards for patients dose assessment in radiophysics. This document continues with description of a part of the project aimed on X-ray radiodiagnostics. The authors of the project were chosen based on their bids to the public grant issued by the Ministry of Health care. The authors used recommendations, guidelines and instructions of international professional societies and IAEA, as well as the already existing procedures and practices while considering possibilities and state of the praxis in the Czech Republic. The outcome of authors work is now an interim version of a document that will be published in the bulletin of the Ministry of Health care. The document contains a set of standards that cover the whole range o fall complimentarily performed ways of patients irradiation in X-ray diagnostics and interventional radiology . The standards are divided to several categories according to the requirement of the Ministry of Health care based on the diagnostic appliances used for diagnostic irradiation i.e. radiography , fluoroscopy, mammography, stomatology, computer tomography, angiography, interventional radiography and cardiography. (authors)

  3. Diagnostic performance of calcification-suppressed coronary CT angiography using rapid kilovolt-switching dual-energy CT

    Energy Technology Data Exchange (ETDEWEB)

    Yunaga, Hiroto; Ohta, Yasutoshi; Kitao, Shinichiro; Ogawa, Toshihide [Tottori University, Division of Radiology, Department of Pathophysiological Therapeutic Science, Faculty of Medicine, Yonago City, Tottori (Japan); Kaetsu, Yasuhiro [Kakogawa Higashi Hospital, Department of Cardiology, Kakogawa (Japan); Watanabe, Tomomi; Furuse, Yoshiyuki; Yamamoto, Kazuhiro [Tottori University, Division of Cardiology, Department of Molecular Medicine and Therapeutics, Faculty of Medicine, Yonago (Japan)

    2017-07-15

    Multi-detector-row computed tomography angiography (MDCTA) plays an important role in the assessment of patients with suspected coronary artery disease. However, MDCTA tends to overestimate stenosis in calcified coronary artery lesions. The aim of our study was to evaluate the diagnostic performance of calcification-suppressed material density (MD) images produced by using a single-detector single-source dual-energy computed tomography (ssDECT). We enrolled 67 patients with suspected or known coronary artery disease who underwent ssDECT with rapid kilovolt-switching (80 and 140 kVp). Coronary artery stenosis was evaluated on the basis of MD images and virtual monochromatic (VM) images. The diagnostic performance of the two methods for detecting coronary artery disease was compared with that of invasive coronary angiography as a reference standard. We evaluated 239 calcified segments. In all the segments, the sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV) and accuracy for detecting significant stenosis were respectively 88%, 88%, 75%, 95% and 88% for the MD images, 91%, 71%, 56%, 95% and 77% for the VM images. PPV was significantly higher on the MD images than on the VM images (P < 0.0001). Calcification-suppressed MD images improved PPV and diagnostic performance for calcified coronary artery lesions. (orig.)

  4. Simulated performance of the optical Thomson scattering diagnostic designed for the National Ignition Facility

    Energy Technology Data Exchange (ETDEWEB)

    Ross, J. S., E-mail: ross36@llnl.gov; Datte, P.; Divol, L.; Galbraith, J.; Hatch, B.; Landen, O.; Manuel, A. M.; Molander, W.; Moody, J. D.; Swadling, G. [Lawrence Livermore National Laboratory, Livermore, California 94551 (United States); Froula, D. H.; Katz, J. [Laboratory for Laser Energetics, University of Rochester, Rochester, New York 14623 (United States); Glenzer, S. H. [SLAC National Accelerator Laboratory, Menlo Park, California 94025 (United States); Kilkenny, J. [General Atomics, San Diego, California 92186 (United States); Montgomery, D. S. [Los Alamos National Laboratory, Los Alamos, New Mexico 87545 (United States); Weaver, J. [Plasma Physics Division, Naval Research Laboratory, Washington, DC 20375 (United States)

    2016-11-15

    An optical Thomson scattering diagnostic has been designed for the National Ignition Facility to characterize under-dense plasmas. We report on the design of the system and the expected performance for different target configurations. The diagnostic is designed to spatially and temporally resolve the Thomson scattered light from laser driven targets. The diagnostic will collect scattered light from a 50 × 50 × 200 μm volume. The optical design allows operation with different probe laser wavelengths. A deep-UV probe beam (λ{sub 0} = 210 nm) will be used to Thomson scatter from electron plasma densities of ∼5 × 10{sup 20} cm{sup −3} while a 3ω probe will be used for plasma densities of ∼1 × 10{sup 19} cm{sup −3}. The diagnostic package contains two spectrometers: the first to resolve Thomson scattering from ion acoustic wave fluctuations and the second to resolve scattering from electron plasma wave fluctuations. Expected signal levels relative to background will be presented for typical target configurations (hohlraums and a planar foil).

  5. Molecular diagnostics of aleutian mink disease virus: applied use of next generation sequencing and phylogenetics

    DEFF Research Database (Denmark)

    Hagberg, Emma Elisabeth

    based either on partial or entire genes, or on pure epidemiological data. Thus, when initiating this project, little was known about AMDV’s total genomic diversity and how the virus was spread between farms. Recent advances in the field of molecular diagnostics have made high throughput tools...... could contribute to the elucidation of AMDV transmission between farms and improve molecular diagnostics. During the first phase of this project a method for performing whole genome sequencing of AMDV was developed. This protocol enabled the sequencing of a large number of in vivo infectious AMDV......-estimates. Altogether, the work presented in this thesis provides a contribution to the molecular diagnostics of AMDV, enables us better to understand the virus’ evolutionary behaviour in the context of mink farming, and is anticipated to be of value for more accurately tracing back in time the emergence of future...

  6. Patient dosimetry in diagnostic radiology

    International Nuclear Information System (INIS)

    Rweyemamu, M.

    2013-04-01

    The objective of this project was to review patient dosimetry aiming at reducing the patient dose during diagnostic procedures while maintaining the best image quality in order to protect patients from ionizing radiation. CT examination was selected in this study to represent imaging protocols with high patient doses used in diagnostic radiology. Dosimetric parameters in CT which are CTDI, CTDIW, DLP, MSAD, organ dose and effective dose were discussed. Parameters such as tube current, tube voltage, filtration, scan volume and slice thickness were found to affect patient dose, therefore proper management of these factors was recommended. For optimization of protection of the patient, application of the “as low as reasonably achievable” (ALARA) principle was recommended as an important key for avoiding overexposure and minimizing patient doses. Also it was recommended that CT examinations should be performed if and only if is the only suitable option when weighed against other options which do not involve ionizing radiation exposure. (author)

  7. CREATION OF OPTIMAL PERFORMANCE OF AN INVESTMENT PROJECT

    Directory of Open Access Journals (Sweden)

    Višnja Vojvodić Rosenzweig

    2010-12-01

    Full Text Available The selection of an investment project is formulated as a multi-criteria decision-making problem. This paper presents a case in which the decision-maker uses nine criteria or rather attributes (Net Present Value, Internal Rate of Return, Payback Period, Accounting Rate of Return, Cumulative Cash Flows, Return on Investment, Net Profit Margin, Interest Coverage Ratio and Current Ratio. Individual utility functions are constructed for each attribute separately, as well as a global utility function representing a weighted sum of individual utility functions. For every attribute a finite set of ordered pairs or utility points is determined, taking into account the decision-maker’s assessment. The given points are then approximated by the utility function. Finally, according to the decision-maker’s assessment the optimization problem is solved with the purpose of achieving an optimal performance for each project. By way of negotiation the performances on offer approach the optimal performance of the project with the purpose of realising an agreement between the decision-maker and the investor.

  8. Final Report on the Research Project Ringhals Diagnostics and Monitoring. Stage 4

    International Nuclear Information System (INIS)

    Demaziere, C.; Arzhanov, V.; Karlsson, Joakim K.H.; Pazsit, I.

    1999-01-01

    This report gives an account of the work performed by the Department of Reactor Physics in the frame of a research contract with Ringhals, Vattenfall AB. The contract constitutes Stage 4 of a long-term co-operative research work concerning diagnostics and monitoring of the BWR and PWR units. The work in Stage 4 has been performed between 1 October 1998 and 1 September 1999. In Stage 4 we have worked with four items as follows: 1. Regional modes in R1 stability measurements; 2. Analysis of data from the measurement 980604; 3. Study of the possibility of measuring the moderator temperature coefficient using noise methods. Literature survey and measurement evaluation; 4. Transfer of the method for determining axial control rod elevation. Current situation and progress

  9. Project management – the way to performance among corporations

    Directory of Open Access Journals (Sweden)

    Luminiţa PISTOL

    2012-06-01

    Full Text Available Project management has developed from a simple management philosophy restricted to a few functional areas into a business process that include various areas from global market. Nowadays, most of the corporations are using project management systems to achieve performance on the global market, and they realize that project management and productivity are related.

  10. A simple, high performance Thomson scattering diagnostic for high temperature plasma research

    International Nuclear Information System (INIS)

    Hartog, D.J.D.; Cekic, M.

    1994-02-01

    This Thomson scattering diagnostic is used to measure the electron temperature and density of the plasma in the MST reversed-field pinch, a magnetic confinement fusion research device. This diagnostic system is unique for its type in that it combines high performance with simple design and low cost components. In the design of this instrument, careful attention was given to the suppression of stray laser line light with simple and effective beam dumps, viewing dumps, aperatures, and a holographic edge filter. This allows the use of a single grating monochromator for dispersion of the Thomson scattered spectrum onto the microchannel plate detector. Alignment and calibration procedures for the laser beam delivery system, the scattered light collection system, and the spectrometer and detector are described. A sample Thomson scattered spectrum illustrates typical data

  11. A Performance Evaluation of Diagnostic X-ray Unit Depends on the Hospitals Size

    Energy Technology Data Exchange (ETDEWEB)

    Park, Ju Hun [Kaya University, Gimhae (Korea, Republic of); Im, In Chul [Gwangju Health College University, Gwangju (Korea, Republic of); Dong, Kyung Rae [Chosun University, Gwangju (Korea, Republic of); Kang, Se Sik [College of Health Science, Catholic University of Pusan, Busan (Korea, Republic of)

    2009-03-15

    The purpose of this study is to measure the tube voltage, the tube current/volume, exposure time and exposure dose of diagnostic X-ray unit in each doctor offices, hospitals and general hospitals for evaluating the performance of such device, to learn the method and technology of its measurement and to suggest its importance. Research subjects were total 30 X-ray units and divided into groups of 10 X-ray units each. The tube voltage, the tube current/volume, exposure time and exposure dose were measured using percentage average error, and then reproducibility of exposure dose was measured through calculating coefficient of variation. The results are like followings; The tube voltage correctness examination showed that incongruent devices among total 30 X-ray units were 5 devices (16.7%). The tube current correctness examination showed that incongruent X-ray units were 3 devices (10.0%). The tube current volume correctness examination showed that incongruent X-ray units were 4 devices (13.3%). Finally, according to exposure time correctness examination, incongruent X-ray units were 5 devices (16.7%) and according to reproducibility examination of exposure dose, incongruent X-ray units were 7 devices (23.3%). Above results showed serious problem in performance management based on management regulation of diagnostic X-ray unit; it means that regular checkout and safety management are required, and as doing so, patients will be able to receive good quality of medical service by the reduction of radiation exposure time, image quality administration, unnecessary retake and etc. Therefore, this study suggests that the performance of diagnostic X-ray units should be checked regularly

  12. A Performance Evaluation of Diagnostic X-ray Unit Depends on the Hospitals Size

    International Nuclear Information System (INIS)

    Park, Ju Hun; Im, In Chul; Dong, Kyung Rae; Kang, Se Sik

    2009-01-01

    The purpose of this study is to measure the tube voltage, the tube current/volume, exposure time and exposure dose of diagnostic X-ray unit in each doctor offices, hospitals and general hospitals for evaluating the performance of such device, to learn the method and technology of its measurement and to suggest its importance. Research subjects were total 30 X-ray units and divided into groups of 10 X-ray units each. The tube voltage, the tube current/volume, exposure time and exposure dose were measured using percentage average error, and then reproducibility of exposure dose was measured through calculating coefficient of variation. The results are like followings; The tube voltage correctness examination showed that incongruent devices among total 30 X-ray units were 5 devices (16.7%). The tube current correctness examination showed that incongruent X-ray units were 3 devices (10.0%). The tube current volume correctness examination showed that incongruent X-ray units were 4 devices (13.3%). Finally, according to exposure time correctness examination, incongruent X-ray units were 5 devices (16.7%) and according to reproducibility examination of exposure dose, incongruent X-ray units were 7 devices (23.3%). Above results showed serious problem in performance management based on management regulation of diagnostic X-ray unit; it means that regular checkout and safety management are required, and as doing so, patients will be able to receive good quality of medical service by the reduction of radiation exposure time, image quality administration, unnecessary retake and etc. Therefore, this study suggests that the performance of diagnostic X-ray units should be checked regularly

  13. Ruling Out Pulmonary Embolism in Primary Care: Comparison of the Diagnostic Performance of "Gestalt" and the Wells Rule

    NARCIS (Netherlands)

    Hendriksen, Janneke M. T.; Lucassen, Wim A. M.; Erkens, Petra M. G.; Stoffers, Henri E. J. H.; van Weert, Henk C. P. M.; Büller, Harry R.; Hoes, Arno W.; Moons, Karel G. M.; Geersing, Geert-Jan

    2016-01-01

    Diagnostic prediction models such as the Wells rule can be used for safely ruling out pulmonary embolism (PE) when it is suspected. A physician's own probability estimate ("gestalt"), however, is commonly used instead. We evaluated the diagnostic performance of both approaches in primary care.

  14. Comparison of 3MP medical-grade to 1MP office grade LCD monitors in mammographic diagnostic and perceptual performance

    International Nuclear Information System (INIS)

    Ong, Aaron; Tan, Shu.; Gledhill, Samuel; Hennessy, Oliver; Lui, Belinda; Lee, Alan; Lemish, Wayne; Styles, Colin; Pun, Emma; Padmanabhan, Meenakshi; Pitman, Alexander G.; Tauro, Paul; Waugh, Paul

    2011-01-01

    Full text: Picture archiving and communication systems images designed to be viewed on high-resolution medical-grade monitors are routinely viewed on office-grade monitors on the wards or at home. This study aimed to determine whether a statistically significant difference in diagnostic (cancer detection) and perceptual (microcalcification detection) performance exists between 3MP grade and 1MP office-grade monitors. 3MP Dome medical-grade liquid crystal display (LCD) monitors (Planar, Beaverton, OR, USA) were compared to 1MP Dell office-grade LCD monitors (Dell Inc, Round Rock, TX, USA). Eight radiologists (reader experi ence 8-30 years) read the same set of 100 mammograms (23/100 with proven cancers and 52/100 with microcalcifications) presented in random order on three occasions separated by two time intervals of 12 weeks. Reads 1 and 3 utilised 3MP monitors and formed the baseline read. Read 2 utilised 1MP monitors and constituted the experimental read. Reading conditions were standardised. Readers were aware of which monitors they were using. Mul tivariate logistic regression analysis (to account for reader variability and monitor impact) was performed to assess for statistical significance. At a = 5%, confidence intervals analysis comparing the measured parameters between 1MP to 3MP monitors demonstrated no statistically significant difference in diagnostic and perceptual performance for the reader group. In cancer detection (the diagnostic task), reader accuracy remained high irrespective of monitor type. Regression analysis comparing performance with 1MP against 3MP monitors found P values of 0.693 and 0.324 for diagnostic and perceptual performance, respectively. There were no statistically and clinically significant differences between 3MP and 1MP monitors in mammographic diagnostic and perceptual performance. Comparable performance may be due to compensatory behav iour by readers.

  15. Accurate Point-of-Care Detection of Ruptured Fetal Membranes: Improved Diagnostic Performance Characteristics with a Monoclonal/Polyclonal Immunoassay

    Directory of Open Access Journals (Sweden)

    Linda C. Rogers

    2016-01-01

    Full Text Available Objective Accurate and timely diagnosis of rupture of membranes (ROM is imperative to allow for gestational age-specific interventions. This study compared the diagnostic performance characteristics between two methods used for the detection of ROM as measured in the same patient. Methods Vaginal secretions were evaluated using the conventional fern test as well as a point-of-care monoclonal/polyclonal immunoassay test (ROM Plus® in 75 pregnant patients who presented to labor and delivery with complaints of leaking amniotic fluid. Both tests were compared to analytical confirmation of ROM using three external laboratory tests. Diagnostic performance characteristics were calculated including sensitivity, specificity, positive predictive value (PPV, negative predictive value (NPV, and accuracy. Results Diagnostic performance characteristics uniformly favored ROM detection using the immunoassay test compared to the fern test: sensitivity (100% vs. 77.8%, specificity (94.8% vs. 79.3%, PPV (75% vs. 36.8%, NPV (100% vs. 95.8%, and accuracy (95.5% vs. 79.1%. Conclusions The point-of-care immunoassay test provides improved diagnostic accuracy for the detection of ROM compared to fern testing. It has the potential of improving patient management decisions, thereby minimizing serious complications and perinatal morbidity.

  16. Diagnostic Performance of Mammographic Texture Analysis in the Differential Diagnosis of Benign and Malignant Breast Tumors.

    Science.gov (United States)

    Li, Zhiming; Yu, Lan; Wang, Xin; Yu, Haiyang; Gao, Yuanxiang; Ren, Yande; Wang, Gang; Zhou, Xiaoming

    2017-11-09

    The purpose of this study was to investigate the diagnostic performance of mammographic texture analysis in the differential diagnosis of benign and malignant breast tumors. Digital mammography images were obtained from the Picture Archiving and Communication System at our institute. Texture features of mammographic images were calculated. Mann-Whitney U test was used to identify differences between the benign and malignant group. The receiver operating characteristic (ROC) curve analysis was used to assess the diagnostic performance of texture features. Significant differences of texture features of histogram, gray-level co-occurrence matrix (GLCM) and run length matrix (RLM) were found between the benign and malignant breast group (P  .05). The AUROCs of imaging-based diagnosis, texture analysis, and imaging-based diagnosis combined with texture analysis were 0.873, 0.863, and 0.961, respectively. When imaging-based diagnosis was combined with texture analysis, the AUROC was higher than that of imaging-based diagnosis or texture analysis (P benign and malignant breast tumors. Furthermore, the combination of imaging-based diagnosis and texture analysis can significantly improve diagnostic performance. Copyright © 2017 Elsevier Inc. All rights reserved.

  17. Development of an EMC3-EIRENE Synthetic Imaging Diagnostic

    Science.gov (United States)

    Meyer, William; Allen, Steve; Samuell, Cameron; Lore, Jeremy

    2017-10-01

    2D and 3D flow measurements are critical for validating numerical codes such as EMC3-EIRENE. Toroidal symmetry assumptions preclude tomographic reconstruction of 3D flows from single camera views. In addition, the resolution of the grids utilized in numerical code models can easily surpass the resolution of physical camera diagnostic geometries. For these reasons we have developed a Synthetic Imaging Diagnostic capability for forward projection comparisons of EMC3-EIRENE model solutions with the line integrated images from the Doppler Coherence Imaging diagnostic on DIII-D. The forward projection matrix is 2.8 Mpixel by 6.4 Mcells for the non-axisymmetric case we present. For flow comparisons, both simple line integral, and field aligned component matrices must be calculated. The calculation of these matrices is a massive embarrassingly parallel problem and performed with a custom dispatcher that allows processing platforms to join mid-problem as they become available, or drop out if resources are needed for higher priority tasks. The matrices are handled using standard sparse matrix techniques. Prepared by LLNL under Contract DE-AC52-07NA27344. This material is based upon work supported by the U.S. DOE, Office of Science, Office of Fusion Energy Sciences. LLNL-ABS-734800.

  18. ICIT contribution to JET gamma-ray diagnostics enhancement

    International Nuclear Information System (INIS)

    Soare, S.; Curuia, M.; Zoita, V.

    2010-01-01

    Full text: Gamma-ray emission of tokamak plasmas is the result of the interaction of fast ions (fusion reaction products, including alpha particles, NBI ions, ICRH-accelerated ions) with main plasma impurities (e.g., carbon, beryllium). Gamma-ray diagnostics involve both gamma-ray imaging (cameras) and gamma-ray spectrometry (spectrometers). For the JET tokamak, gamma-ray diagnostics have been used to provide information on the characteristics of the fast ion population in plasmas. Two gamma-ray diagnostics enhancements project have been launched by JET and the MEdC/EURATOM Association has agreed to lead both of them with ICIT as projects leader. (authors)

  19. Penetrating Colorectal Injuries: Diagnostic Performance of Multidetector CT with Trajectography.

    Science.gov (United States)

    Dreizin, David; Boscak, Alexis R; Anstadt, Michael J; Tirada, Nikki; Chiu, William C; Munera, Felipe; Bodanapally, Uttam K; Hornick, Michael; Stein, Deborah M

    2016-12-01

    Purpose To determine the diagnostic performance of multidetector computed tomography (CT) with trajectography for penetrating colorectal injuries. Materials and Methods This institutional review board-approved and HIPAA-compliant study was a 6-year blinded retrospective review by two independent readers of 182 consecutive patients who preoperatively underwent 40- or 64-row multidetector CT for penetrating torso trauma below the diaphragm and had surgically confirmed findings. Colorectal perforation was present in 42 patients. Trajectory analysis with postprocessing software was used for all studies. Additional signs evaluated were rectal contrast agent leak, collections of extruded fecal material, mural defect, wall thickening, abnormal enhancement, free fluid or stranding, and free air. The quality of the colorectal contrast agent administration was recorded. Sensitivity, specificity, predictive values, areas under the receiver operating characteristic curves (AUCs), and Cohen κ were determined. Results In patients with rectal contrast agent administration (n = 151), AUCs were 0.90-0.91, which indicated excellent accuracy. Trajectory was sensitive (88%-91%). For single wounds (n = 104), sensitivity of trajectory was 96% for both readers, but was only 80% for multiple wounds (n = 47). Contrast agent leak was highly specific (96%-98%), but insensitive (42%-46%). Improved diagnostic performance was observed in patients with poor colonic distension or opacification. Accuracy remained high (AUC, 0.86-0.99) in the group without rectal contrast agent administration (n = 31). Conclusion Trajectory had excellent sensitivity, while rectal contrast agent leak was specific but insensitive. Sensitivity of trajectory was lower for multiple wounds. Accuracy remained high in patients without rectal contrast agent administration. © RSNA, 2016.

  20. Process performance indicators in project pre-design stage

    NARCIS (Netherlands)

    Haponava, T.; Al-Jibouri, Saad H.S.; Reymen, Isabelle; Scheublin, F.; Pronk, A.; Prins, M.; Emmitt, S.; den Otter, A

    2006-01-01

    Traditionally performance in construction is measured based on the "iron-triangle”- time, cost and quality. In recent years indicators have been developed to include the measurements of other aspects of project performance. The main shortcoming of these however is that most of them are lagging

  1. FINAL REPORT: Building Performance Optimization while Empowering Occupants Toward Environmentally Sustainable Behavior through Continuous Monitoring and Diagnostics

    Science.gov (United States)

    2016-12-05

    Federal Energy Management Program FM Facility Manager GHG Green House Gases HASP Health and Safety Plan HVAC Heating Ventilation and... workplace energy efficiency enhancement by the DOD personnel. 2.1.2 ID-F Intelligent Dashboards for Facility Managers Creation of the Base Building...demonstration project. The first technology, ‘ID-F,’ targets building facility managers and allows real time diagnostics for BAS systems with features

  2. Plasma diagnostics package. Volume 2: Spacelab 2 section. Part B: Thesis projects

    Science.gov (United States)

    Pickett, Jolene S. (Compiler); Frank, L. A. (Compiler); Kurth, W. S. (Compiler)

    1988-01-01

    This volume (2), which consists of two parts (A and B), of the Plasma Diagnostics Package (PDP) Final Science Report contains a summary of all of the data reduction and scientific analyses which were performed using PDP data obtained on STS-51F as a part of the Spacelab 2 (SL-2) payload. This work was performed during the period of launch, July 29, 1985, through June 30, 1988. During this period the primary data reduction effort consisted of processing summary plots of the data received by 12 of the 14 instruments located on the PDP and submitting these data to the National Space Science Data Center (NSSDC). Three Master's and three Ph.D. theses were written using PDP instrumentation data. These theses are listed in Volume 2, Part B.

  3. Iterative performance assessments as a regulatory tool for evaluating repository safety: How experiences from SKI Project-90 were used in formulating the new performance assessment project SITE-94

    International Nuclear Information System (INIS)

    Andersson, J.

    1993-01-01

    The Swedish Nuclear Power Inspectorate, SKI, regulatory research program has to prepare for the process of licensing a repository for spent nuclear fuel, by building up the necessary knowledge and review capacity. SKIs main strategy for meeting this demand is to develop an independent performance assessment capability. SKIs first own performance assessment project, Project-90, was completed in 1991 and is now followed by a new project, SITE-94. SITE-94 is based on conclusions reached within Project-90. An independent review of Project-90, carried out by a NEA team of experts, has also contributed to the formation of the project. Another important reason for the project is that the implementing organization in Sweden, SKB, has proposed to submit an application to start detailed investigation of a repository candidate site around 1997. SITE-94 is a performance assessment of a hypothetical repository at a real site. The main objective of the project is to determine how site specific data should be assimilated into the performance assessment process, and to evaluate how uncertainties inherent in site characterization will influence performance assessment results. This will be addressed by exploring multiple interpretations, conceptual models, and parameters consistent with the site data. The site evaluation will strive for consistency between geological, hydrological, rock mechanical, and geochemical descriptions. Other important elements of SITE-94 are the development of a practical and defensible methodology for defining, constructing and analyzing scenarios, the development of approaches for treatment of uncertainties, evaluation of canister integrity, and the development and application of an appropriate quality assurance plan for performance assessments

  4. Diagnostic Performance of Bronchoalveolar Lavage Fluid CD4/CD8 Ratio for Sarcoidosis: A Meta-analysis.

    Science.gov (United States)

    Shen, Yongchun; Pang, Caishuang; Wu, Yanqiu; Li, Diandian; Wan, Chun; Liao, Zenglin; Yang, Ting; Chen, Lei; Wen, Fuqiang

    2016-06-01

    The usefulness of bronchoalveolar lavage fluid (BALF) CD4/CD8 ratio for diagnosing sarcoidosis has been reported in many studies with variable results. Therefore, we performed a meta-analysis to estimate the overall diagnostic accuracy of BALF CD4/CD8 ratio based on the bulk of published evidence. Studies published prior to June 2015 and indexed in PubMed, OVID, Web of Science, Scopus and other databases were evaluated for inclusion. Data on sensitivity, specificity, positive likelihood ratio (PLR), negative likelihood ratio (NLR), and diagnostic odds ratio (DOR) were pooled from included studies. Summary receiver operating characteristic (SROC) curves were used to summarize overall test performance. Deeks's funnel plot was used to detect publication bias. Sixteen publications with 1885 subjects met our inclusion criteria and were included in this meta-analysis. Summary estimates of the diagnostic performance of the BALF CD4/CD8 ratio were as follows: sensitivity, 0.70 (95%CI 0.64-0.75); specificity, 0.83 (95%CI 0.78-0.86); PLR, 4.04 (95%CI 3.13-5.20); NLR, 0.36 (95%CI 0.30-0.44); and DOR, 11.17 (95%CI 7.31-17.07). The area under the SROC curve was 0.84 (95%CI 0.81-0.87). There was no evidence of publication bias. Measuring the BALF CD4/CD8 ratio may assist in the diagnosis of sarcoidosis when interpreted in parallel with other diagnostic factors. Copyright © 2016 The Authors. Published by Elsevier B.V. All rights reserved.

  5. UWGSP6: a diagnostic radiology workstation of the future

    Science.gov (United States)

    Milton, Stuart W.; Han, Sang; Choi, Hyung-Sik; Kim, Yongmin

    1993-06-01

    The Univ. of Washington's Image Computing Systems Lab. (ICSL) has been involved in research into the development of a series of PACS workstations since the middle 1980's. The most recent research, a joint UW-IBM project, attempted to create a diagnostic radiology workstation using an IBM RISC System 6000 (RS6000) computer workstation and the X-Window system. While the results are encouraging, there are inherent limitations in the workstation hardware which prevent it from providing an acceptable level of functionality for diagnostic radiology. Realizing the RS6000 workstation's limitations, a parallel effort was initiated to design a workstation, UWGSP6 (Univ. of Washington Graphics System Processor #6), that provides the required functionality. This paper documents the design of UWGSP6, which not only addresses the requirements for a diagnostic radiology workstation in terms of display resolution, response time, etc., but also includes the processing performance necessary to support key functions needed in the implementation of algorithms for computer-aided diagnosis. The paper includes a description of the workstation architecture, and specifically its image processing subsystem. Verification of the design through hardware simulation is then discussed, and finally, performance of selected algorithms based on detailed simulation is provided.

  6. Diagnostic performance of shear wave elastography of the breast according to scanning orientation.

    Science.gov (United States)

    Kim, Solip; Choi, SeonHyeong; Choi, Yoonjung; Kook, Shin-Ho; Park, Hee Jin; Chung, Eun Chul

    2014-10-01

    To evaluate the influence of the scanning orientation on diagnostic performance measured by the mean elasticity, maximum elasticity, and fat-to-lesion elasticity ratio on ultrasound-based shear wave elastography in differentiating breast cancers from benign lesions. In this study, a total of 260 breast masses from 235 consecutive patients were observed from March 2012 to November 2012. For each lesion, the mean elasticity value, maximum elasticity value, and fat-to-lesion ratio were measured along two orthogonal directions, and all values were compared with pathologic results. There were 59 malignant and 201 benign lesions. Malignant masses showed higher mean elasticity, maximum elasticity, and fat-to-lesion ratio values than benign lesions (P masses; and mean elasticity, 0.392, for anterior mammary fat. Mean elasticity, maximum elasticity, and fat-to-lesion elasticity ratio values were helpful in differentiating benign and malignant breast masses. The scanning orientation did not significantly affect the diagnostic performance of shear wave elastography for breast masses. © 2014 by the American Institute of Ultrasound in Medicine.

  7. Comparing Performance of Government and Private Clients in Construction Projects: Contractors’ Perspective

    OpenAIRE

    Jati Utomo Dwi Hatmoko; Riqi Radian Khasania

    2016-01-01

    By nature, government and private projects have different characteristics, which influence client performance. This research aims to compare performance of government and private clients in construction projects as perceived by contractors. Six client performance indicators were used, i.e. understanding of project requirements, financial, decision making, management skills, supports for contractor, and client’s attitude. Data were collected through questionnaire surveys filled in by 117 respo...

  8. Performance Assessment Framework for Private Finance Initiative Projects in Malaysia

    Directory of Open Access Journals (Sweden)

    Lop Nor Suzila

    2016-01-01

    Full Text Available Private Finance Initiative (PFI is viewed as restructuring the previous privatisation concept in delivering value for money for the Malaysian public infrastructure. Among the restructuring efforts in the privatisation is specifying the standard assessment of private concessionaires’ performance through the execution of key performance indicators (KPIs where the private concessionaires’ performance is benchmarked against the government’s standard. KPIs have served as useful tools in assessing performance of PFI projects. However, there is still lacking on determination methods performed to define and measure this KPIs and the absence of guidelines or a framework is also an issue in the implementation of the PFI procurement in Malaysia. Therefore, the objectives of this paper is to investigate the notion of performance assessment model approaches globally (i.e. UK, China, Australia, Serbia and Malaysia and to identify direction for PFI performance assessment tools (KPIs to be practiced in Malaysia. Based on the consideration of these models, this research paper propose an initial framework of performance assessment for PFI projects in Malaysia. The framework is deliberate to cover the performance of PFI at the operation and maintenance phase. The outcomes of this paper can serve as a theoretical base for the development of comprehensive and effective performance assessment for PFI projects in Malaysia.

  9. Evaluating the Performance Diagnostic Checklist-Human Services to Assess Incorrect Error-Correction Procedures by Preschool Paraprofessionals

    Science.gov (United States)

    Bowe, Melissa; Sellers, Tyra P.

    2018-01-01

    The Performance Diagnostic Checklist-Human Services (PDC-HS) has been used to assess variables contributing to undesirable staff performance. In this study, three preschool teachers completed the PDC-HS to identify the factors contributing to four paraprofessionals' inaccurate implementation of error-correction procedures during discrete trial…

  10. DIAGNOSTIC METHODS IN BREAST CANCER DETECTION

    Directory of Open Access Journals (Sweden)

    Kristijana Hertl

    2018-02-01

    Full Text Available Background. In the world as well as in Slovenia, breast cancer is the most frequent female cancer. Due to its high incidence, it appears to be a serious health and economic problem. Content. Among other, tumour size at diagnosis, is an important prognostic factors of the course of the disease. The probability of axillary lymph node involvement as well as distant metastases is greater in larger tumours. This is the reason that encouraged the development of various diagnostic methods for early detection of small, clinically non-palpable breast tumours. Mammography, however, remains the »golden standard« of early breast cancer detection. It is the basic diagnostic method applied in all symptomatic women over 35 years of age and in asymptomatic women over 40 years of age. Ultrasonography (US, additional projections, magnetic resonance imaging (MRI and ductography are regarded as complementary diagnostic breast imaging techniques in addition to mammography. The detected changes in the breast can be further confirmed by US-, MR-guided or stereotactic biopsy. If necessary, surgical biopsy and the excision of a tissue sample, after wire or isotope localisation of the nonpalpable lesion, can be performed. Conclusions. Any of the above mentioned diagnostic methods has advantages as well as drawbacks and only detailed knowledge and understanding of each of them may assure the best option.

  11. Diagnostic performance of BMI percentiles to identify adolescents with metabolic syndrome.

    Science.gov (United States)

    Laurson, Kelly R; Welk, Gregory J; Eisenmann, Joey C

    2014-02-01

    To compare the diagnostic performance of the Centers for Disease Control and Prevention (CDC) and FITNESSGRAM (FGram) BMI standards for quantifying metabolic risk in youth. Adolescents in the NHANES (n = 3385) were measured for anthropometric variables and metabolic risk factors. BMI percentiles were calculated, and youth were categorized by weight status (using CDC and FGram thresholds). Participants were also categorized by presence or absence of metabolic syndrome. The CDC and FGram standards were compared by prevalence of metabolic abnormalities, various diagnostic criteria, and odds of metabolic syndrome. Receiver operating characteristic curves were also created to identify optimal BMI percentiles to detect metabolic syndrome. The prevalence of metabolic syndrome in obese youth was 19% to 35%, compared with <2% in the normal-weight groups. The odds of metabolic syndrome for obese boys and girls were 46 to 67 and 19 to 22 times greater, respectively, than for normal-weight youth. The receiver operating characteristic analyses identified optimal thresholds similar to the CDC standards for boys and the FGram standards for girls. Overall, BMI thresholds were more strongly associated with metabolic syndrome in boys than in girls. Both the CDC and FGram standards are predictive of metabolic syndrome. The diagnostic utility of the CDC thresholds outperformed the FGram values for boys, whereas FGram standards were slightly better thresholds for girls. The use of a common set of thresholds for school and clinical applications would provide advantages for public health and clinical research and practice.

  12. QLab 3 show control projects for live performances & installations

    CERN Document Server

    Hopgood, Jeromy

    2013-01-01

    Used from Broadway to Britain's West End, QLab software is the tool of choice for many of the world's most prominent sound, projection, and integrated media designers. QLab 3 Show Control: Projects for Live Performances & Installations is a project-based book on QLab software covering sound, video, and show control. With information on both sound and video system basics and the more advanced functions of QLab such as MIDI show control, new OSC capabilities, networking, video effects, and microphone integration, each chapter's specific projects will allow you to learn the software's capabilitie

  13. Supervision and Performance : The Case of World Bank Projects

    NARCIS (Netherlands)

    Kilby, C.

    1995-01-01

    This paper explores empirical aspects of the relation between supervision and project performance. I focus on development projects funded by the World Bank and on supervision done by the World Bank. The World Bank is the preeminent international development organization both in terms of money lent

  14. Optimization of Classification Strategies of Acetowhite Temporal Patterns towards Improving Diagnostic Performance of Colposcopy

    Directory of Open Access Journals (Sweden)

    Karina Gutiérrez-Fragoso

    2017-01-01

    Full Text Available Efforts have been being made to improve the diagnostic performance of colposcopy, trying to help better diagnose cervical cancer, particularly in developing countries. However, improvements in a number of areas are still necessary, such as the time it takes to process the full digital image of the cervix, the performance of the computing systems used to identify different kinds of tissues, and biopsy sampling. In this paper, we explore three different, well-known automatic classification methods (k-Nearest Neighbors, Naïve Bayes, and C4.5, in addition to different data models that take full advantage of this information and improve the diagnostic performance of colposcopy based on acetowhite temporal patterns. Based on the ROC and PRC area scores, the k-Nearest Neighbors and discrete PLA representation performed better than other methods. The values of sensitivity, specificity, and accuracy reached using this method were 60% (95% CI 50–70, 79% (95% CI 71–86, and 70% (95% CI 60–80, respectively. The acetowhitening phenomenon is not exclusive to high-grade lesions, and we have found acetowhite temporal patterns of epithelial changes that are not precancerous lesions but that are similar to positive ones. These findings need to be considered when developing more robust computing systems in the future.

  15. Causes of Low-Skilled Workers’ Performance in Construction Projects

    Directory of Open Access Journals (Sweden)

    Alhaji Ali Zannah

    2017-06-01

    Full Text Available Skilled workers’ performance is one of the crucial aspects of labour productivity that requires proper attention for effective projects delivery in the construction industry. The level of skilled workers’ low performance has been seen to be a major factor which contributes toward inefficient construction projects productivity. Therefore, the objective of this research is to identify the causes of low-skilled workers’ performance in construction projects in the Nigeria. The objective was achieved through a structured quantitative method of questionnaire distributed to 150 respondents that comprise of active stakeholders in the Nigerian construction industry. 111 responses representing 74 % were retrieved. The data were analysed using descriptive statistics and analysis of variance (ANOVA. The finding shows that; low wages of skilled, lack of sufficient skill acquisition centres and lack of incentive schemes for skilled workers were the most significant causes of low-skilled workers’ performance in the Nigerian construction industry. The homogenous analysis indicates that there are significant differences in perception of respondents on few variables whereas majority of respondents have similarities in most of the variables. The research findings indicate the need for stakeholders in the Nigerian construction industry to provide incentives and motivate skilled workers, provide training and retraining, conducive working condition, supply of quality materials and equipment, and proper site management in order improve low-skilled workers’ performance in Nigerian construction industry towards optimal performance.

  16. Project Leader's Dual Socialization and Its Impact on Team Learning and Performance: A Diagnostic Study

    Science.gov (United States)

    Gautam, Tanvi

    2009-01-01

    One of the important challenges for leadership in project teams is the ability to manage the knowledge, communication and coordination related activities of team. In cross-team collaboration, different boundaries contribute to the situated nature of knowledge and hamper the flow of knowledge and prevent shared understanding with those on the other…

  17. AHP-based risk analysis of energy performance contracting projects in Russia

    International Nuclear Information System (INIS)

    Garbuzova-Schlifter, Maria; Madlener, Reinhard

    2016-01-01

    Understanding and properly managing risks that could potentially affect the target- and performance-based profits of energy performance contracting (EPC) projects are essential. It is particularly important for the establishment and success of energy service companies (ESCOs) acting in the vulnerable environment of the vast but highly energy-inefficient Russian market. This study systematically explores common risk factors and causes of risk associated with EPC projects executed in three Russian sectors: (1) industrial; (2) housing and communal services; and (3) public. Several interviews with the Russian EPC experts were accomplished and a qualitative risk assessment by using an analytic hierarchy process (AHP) approach. The data were obtained from a web-based questionnaire survey conducted among Russian EPC project executors. For each focus sector, a specific preference-based ranking of the identified risk factors and causes of risk was derived. The AHP results show that causes of risk related to the financial and regulatory aspects contribute most to the riskiness of EPC projects performed in all three focus sectors in Russia, calling for the special attention of EPC policy- and business-makers. Due to sectorial particularities and different actors involved, we conclude that there is a need for elaboration of sector-specific contractual schemes for EPC projects. - Highlights: • AHP- and survey-based study of energy performance contracting (EPC) projects in Russia. • Main risk factors and causes of risk associated with EPC projects are investigated. • In practice, lack of a feasible risk management approach in EPC projects. • Regulatory and financial risks contribute most to the EPC projects’ riskiness. • Elaboration of the sector-specific EPC project contractual scheme is required.

  18. Performance Evaluation of Commercial Dengue Diagnostic Tests for Early Detection of Dengue in Clinical Samples

    Directory of Open Access Journals (Sweden)

    Tuan Nur Akmalina Mat Jusoh

    2017-01-01

    Full Text Available The shattering rise in dengue virus infections globally has created a need for an accurate and validated rapid diagnostic test for this virus. Rapid diagnostic test (RDT and reverse transcription-polymerase chain reaction (RT-PCR diagnostic detection are useful tools for diagnosis of early dengue infection. We prospectively evaluated the diagnostic performance of nonstructural 1 (NS1 RDT and real-time RT-PCR diagnostic kits in 86 patient serum samples. Thirty-six samples were positive for dengue NS1 antigen while the remaining 50 were negative when tested with enzyme-linked immunosorbent assay (ELISA. Commercially available RDTs for NS1 detection, RTK ProDetect™, and SD Bioline showed high sensitivity of 94% and 89%, respectively, compared with ELISA. GenoAmp® Trioplex Real-Time RT-PCR and RealStar® Dengue RT-PCR tests presented a comparable kappa agreement with 0.722. The result obtained from GenoAmp® Real-Time RT-PCR Dengue test showed that 14 samples harbored dengue virus type 1 (DENV-1, 8 samples harbored DENV-2, 2 samples harbored DENV-3, and 1 sample harbored DENV-4. 1 sample had a double infection with DENV-1 and DENV-2. The NS1 RDTs and real-time RT-PCR tests were found to be a useful diagnostic for early and rapid diagnosis of acute dengue and an excellent surveillance tool in our battle against dengue.

  19. Virtual Resting Pd/Pa From Coronary Angiography and Blood Flow Modelling: Diagnostic Performance Against Fractional Flow Reserve.

    Science.gov (United States)

    Papafaklis, Michail I; Muramatsu, Takashi; Ishibashi, Yuki; Bourantas, Christos V; Fotiadis, Dimitrios I; Brilakis, Emmanouil S; Garcia-Garcia, Héctor M; Escaned, Javier; Serruys, Patrick W; Michalis, Lampros K

    2018-03-01

    Fractional flow reserve (FFR) has been established as a useful diagnostic tool. The distal coronary pressure to aortic pressure (Pd/Pa) ratio at rest is a simpler physiologic index but also requires the use of the pressure wire, whereas recently proposed virtual functional indices derived from coronary imaging require complex blood flow modelling and/or are time-consuming. Our aim was to test the diagnostic performance of virtual resting Pd/Pa using routine angiographic images and a simple flow model. Three-dimensional quantitative coronary angiography (3D-QCA) was performed in 139 vessels (120 patients) with intermediate lesions assessed by FFR. The resting Pd/Pa for each lesion was assessed by computational fluid dynamics. The discriminatory power of virtual resting Pd/Pa against FFR (reference: ≤0.80) was high (area under the receiver operator characteristic curve [AUC]: 90.5% [95% CI: 85.4-95.6%]). Diagnostic accuracy, sensitivity and specificity for the optimal virtual resting Pd/Pa cut-off (≤0.94) were 84.9%, 90.4% and 81.6%, respectively. Virtual resting Pd/Pa demonstrated superior performance (pvirtual resting Pd/Pa and FFR (r=0.69, pVirtual resting Pd/Pa using routine angiographic data and a simple flow model provides fast functional assessment of coronary lesions without requiring the pressure-wire and hyperaemia induction. The high diagnostic performance of virtual resting Pd/Pa for predicting FFR shows promise for using this simple/fast virtual index in clinical practice. Copyright © 2017 Australian and New Zealand Society of Cardiac and Thoracic Surgeons (ANZSCTS) and the Cardiac Society of Australia and New Zealand (CSANZ). Published by Elsevier B.V. All rights reserved.

  20. Diagnostic performance of calcification-suppressed coronary CT angiography using rapid kilovolt-switching dual-energy CT.

    Science.gov (United States)

    Yunaga, Hiroto; Ohta, Yasutoshi; Kaetsu, Yasuhiro; Kitao, Shinichiro; Watanabe, Tomomi; Furuse, Yoshiyuki; Yamamoto, Kazuhiro; Ogawa, Toshihide

    2017-07-01

    Multi-detector-row computed tomography angiography (MDCTA) plays an important role in the assessment of patients with suspected coronary artery disease. However, MDCTA tends to overestimate stenosis in calcified coronary artery lesions. The aim of our study was to evaluate the diagnostic performance of calcification-suppressed material density (MD) images produced by using a single-detector single-source dual-energy computed tomography (ssDECT). We enrolled 67 patients with suspected or known coronary artery disease who underwent ssDECT with rapid kilovolt-switching (80 and 140 kVp). Coronary artery stenosis was evaluated on the basis of MD images and virtual monochromatic (VM) images. The diagnostic performance of the two methods for detecting coronary artery disease was compared with that of invasive coronary angiography as a reference standard. We evaluated 239 calcified segments. In all the segments, the sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV) and accuracy for detecting significant stenosis were respectively 88%, 88%, 75%, 95% and 88% for the MD images, 91%, 71%, 56%, 95% and 77% for the VM images. PPV was significantly higher on the MD images than on the VM images (P < 0.0001). Calcification-suppressed MD images improved PPV and diagnostic performance for calcified coronary artery lesions. • Computed tomography angiography tends to overestimate stenosis in calcified coronary artery. • Dual-energy CT enables us to suppress calcification of coronary artery lesions. • Calcification-suppressed material density imaging reduces false-positive diagnosis of calcified lesion.

  1. Ruling out pulmonary embolism in primary care : Comparison of the diagnostic performance of “gestalt” and the wells rule

    NARCIS (Netherlands)

    Hendriksen, Janneke M T; Lucassen, Wim A M; Erkens, Petra M G; Stoffers, Henri E J H; van Weert, Henk C P M; Büller, Harry R.; Hoes, Arno W.; Moons, Karel G M; Geersing, Geert Jan

    2016-01-01

    PURPOSE Diagnostic prediction models such as the Wells rule can be used for safely ruling out pulmonary embolism (PE) when it is suspected. A physician’s own probability estimate (“gestalt”), however, is commonly used instead. We evaluated the diagnostic performance of both approaches in primary

  2. Elastography for Thyroid Nodules: The Comparison of Diagnostic Performance on Transverse and Longitudinal Planes

    International Nuclear Information System (INIS)

    Moon, Hee Jung; Kwak, Jin Young; Kim, Eun Kyung

    2012-01-01

    To evaluate the diagnostic performance of elastography for thyroid nodules on the transverse and longitudinal planes. Gray scale ultrasonography (US), elastography on trans- verse and longitudinal planes, and fine needle aspiration biopsy for 78 thyroid nodules (malignant: 34 cases, benign: 44 cases) were performed. According to the Asteria criteria of elastography, scores 1 and 2 were classified as probably benign and scores 3 and 4 were classified as suspicious. Strain ratios on transverse and longitudinal planes were measured. Sensitivity, specificity, positive predictive value, negative predictive value, accuracy, and Az value (under the receiver operating characteristics curve) of elastography on transverse and longitudinal planes were calculated and compared. Scores 3 and 4 were more frequently seen in malignant nodules on the longitudinal plane (p value = 0.007), but not significantly seen on the transverse plane (p value = 0.160). Sensitivity, specificity, positive predictive value, negative predictive value, accuracy, and the Az value of elastography on the longitudinal plane were higher than those on the transverse plane, although Az values on the transverse and longtudinal planes were not statistically significant. Diagnostic performance of thyroid elastography, especially sensitivity, were higher on the longitudinal plane than the transverse plane

  3. Performance of RGB laser-based projection for video walls

    Science.gov (United States)

    Hickl, Peter

    2018-02-01

    The laser phosphor concept is currently the common approach for most applications to introduce laser as a projection light source. However, this concept bears quite some disadvantages for rear-projection video walls. Therefore, Barco has developed a RGB laser design for use in the control room market with tailor-made performance.

  4. Relation of project managers' personality and project performance: An approach based on value stream mapping

    Directory of Open Access Journals (Sweden)

    Maurizio Bevilacqua

    2014-09-01

    Full Text Available Purpose: This work investigates the influence of project managers’ personality on the success of a project in a Multinational Corporation. The methodology proposed for analyzing the project managers’ personality is based on the Myers-Briggs Type Indicator.Design/methodology/approach: Forty projects carried out in 2012 by multinational corporation, concerning new product development (NPD, have been analyzed, comparing the profile of project managers with results obtained in terms of traditional performance indexes (time delay and over-budget of projects and performance indexes usually used in “Lean Production” sector (waste time and type of “wastes”. A detailed analysis of the most important “wastes” during the project development is carried out using the Value Stream Mapping (VSM technique.Findings and Originality/value: Relying on the Myers–Briggs personality instrument, results show that extroverted managers (as opposed to introverted managers carry out projects that show lower delay and lower waste time. Introverted managers often make “Over-processing” and “Defect” types of waste. Moreover, lower delay and over-budget have been shown by perceiving managers.Research limitations: Regarding the limitations of this work it is necessary to highlight that we collected data from project managers in a retrospective way. While we believe that several aspects of our data collection effort helped enhance the accuracy of the results, future research could conduct real-time case study research to get more detailed insights into the proposed relationships and avoid retrospective bias. Moreover we focused on a single respondent, the project manager. This helped us ensure that their interpretations played an important role in product development. But, we cannot examined the opinion of team members that could be different from project managers opinion regarding some questions.Originality/value: This research provides insight useful

  5. Development of high performance Schottky barrier diode and its application to plasma diagnostics

    International Nuclear Information System (INIS)

    Fujita, Junji; Kawahata, Kazuo; Okajima, Shigeki

    1993-10-01

    At the conclusion of the Supporting Collaboration Research on 'Development of High Performance Detectors in the Far Infrared Range' carried out from FY1990 to FY1992, the results of developing Schottky barrier diode and its application to plasma diagnostics are summarized. Some remarks as well as technical know-how for the correct use of diodes are also described. (author)

  6. Xanthogranulomatous cholecystitis: Diagnostic performance of CT to differentiate from gallbladder cancer

    Energy Technology Data Exchange (ETDEWEB)

    Goshima, Satoshi, E-mail: gossy@par.odn.ne.j [Department of Radiology, University of Pittsburgh Medical Center, Lothrop St., Pittsburgh, PA 15213 (United States); Department of Radiology, Gifu University School of Medicine, 1-1 Yanagido, Gifu 501-1194 (Japan); Chang, Samuel; Wang, Jin Hong [Department of Radiology, University of Pittsburgh School of Medicine, 3362 Fifth Ave., Pittsburgh, PA15213 (United States); Kanematsu, Masayuki [Department of Radiology, Gifu University School of Medicine, 1-1 Yanagido, Gifu 501-1194 (Japan); Department of Radiology Services, Gifu University School of Medicine, 1-1- Yanagido, Gifu 501-1194 (Japan); Bae, Kyongtae T. [Department of Radiology, University of Pittsburgh School of Medicine, 3362 Fifth Ave., Pittsburgh, PA15213 (United States); Federle, Michael P. [Department of Radiology, University of Pittsburgh Medical Center, Lothrop St., Pittsburgh, PA 15213 (United States); Department of Radiology, Stanford University Medical Center, 300 Pasteur Drive, Stanford, CA 94305-5105 (United States)

    2010-06-15

    Purpose: To retrospectively evaluate CT findings of xanthogranulomatous cholecystitis (XGC) and to measure diagnostic performance for distinguishing it from gallbladder (GB) cancer. Methods and materials: Our institutional review board approved this retrospective study. Three blinded radiologists, first independently and then in consensus, retrospectively evaluated postcontrast CT images of 35 patients with histopathologically proved XGC and GB cancer, all of whom subsequently had cholecystectomy. These included 18 patients with XGC (13 male, 5 female; age range, 35-84, mean 63 years) and 17 with GB cancer (6 male, 11 female; age range, 45-95, mean 69). Differences in CT findings between XGC and GB cancer and diagnostic performances for each CT finding were calculated. Sensitivity, specificity, and accuracy were calculated for each radiologist and observer performance was also determined by receiver-operating-characteristic curve analysis. Results: Five CT findings showed significant differences between XGC and GB cancer. Sensitivity, specificity, and accuracy of each finding for the differentiation of XGC were 89%, 65%, 77% with diffuse GB wall thickening, 67%, 82%, 74% with a continuous mucosal line, 61%, 71%, 66% with intra-mural hypo-attenuated nodules, 72%, 77%, 74% with absence of macroscopic hepatic invasion, and 67%, 71%, 69% with absence of intra-hepatic bile duct dilatation, respectively. When at least three of these five CT findings were observed in combination, sensitivity, specificity, and accuracy were 83%, 100% and 91%, respectively. Sensitivities, specificities and Az values for the differentiation of XGC from GB cancer were 83%, 88%, 0.94 for reader 1, 78%, 88%, 0.93 for reader 2, and 78%, 82%, 0.84 for reader 3. Conclusions: The combination of three of the five CT findings that are common with XGC can provide excellent accuracy for the differentiation of XGC and GB cancer.

  7. Diagnostic performance and useful findings of ultrasound re-evaluation for patients with equivocal CT features of acute appendicitis.

    Science.gov (United States)

    Kim, Mi Sung; Kwon, Heon-Ju; Kang, Kyung A; Do, In-Gu; Park, Hee-Jin; Kim, Eun Young; Hong, Hyun Pyo; Choi, Yoon Jung; Kim, Young Hwan

    2018-02-01

    To evaluate the diagnostic performance of ultrasound and to determine which ultrasound findings are useful to differentiate appendicitis from non-appendicitis in patients who underwent ultrasound re-evaluation owing to equivocal CT features of acute appendicitis. 62 patients who underwent CT examinations for suspected appendicitis followed by ultrasound re-evaluation owing to equivocal CT findings were included. Equivocal CT findings were considered based on the presence of only one or two findings among the CT criteria, and ultrasound re-evaluation was done based on a predefined structured report form. The diagnostic performance of ultrasound and independent variables to discriminate appendicitis from non-appendicitis were assessed. There were 27 patients in the appendicitis group. The overall diagnostic performance of ultrasound re-evaluation was sensitivity of 96.3%, specificity of 91.2% and accuracy of 91.9%. In terms of the performance of individual ultrasound findings, probe-induced tenderness showed the highest accuracy (86.7%) with sensitivity of 74% and specificity of 97%, followed by non-compressibility (accuracy 71.7%, sensitivity 85.2% and specificity 60.6%). The independent ultrasound findings for discriminating appendicitis were non-compressibility (p = 0.002) and increased flow on the appendiceal wall (p = 0.001). Ultrasound re-evaluation can be used to improve diagnostic accuracy in cases with equivocal CT features for diagnosing appendicitis. The presence of non-compressibility and increased vascular flow on the appendix wall are useful ultrasound findings to discriminate appendicitis from non-appendicitis. Advances in knowledge: Ultrasound re-evaluation is useful to discriminate appendicitis from non-appendicitis when CT features are inconclusive.

  8. The PERFORM project: using performing arts to increase engagement and understanding of science.

    Science.gov (United States)

    James, Jon

    2017-04-01

    This commentary describes some of the current challenges for science education in the UK and how an EU educational project (PERFORM) is seeking to use performing arts to engage young people with science, its values and the processes of research. © FEMS 2017. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  9. Critical success factors influencing the performance of development projects: An empirical study of Constituency Development Fund projects in Kenya

    Directory of Open Access Journals (Sweden)

    Debadyuti Das

    2017-12-01

    Full Text Available The present work attempts to identify critical success factors (CSFs influencing the performance of development projects based on their key performance indicators (KPIs. It has considered the case of Constituency Development Fund (CDF projects constructed between 2003 and 2011 in Kenya and secured the perceptions of 175 respondents comprising clients, consultants and contractors involved in the implementation of CDF projects on 30 success variables. Findings reveal that individual items constituting these six factors represent six CSFs namely project-related, client-related, consultant-related, contractor-related, supply chain-related, and external environment-related factor. The findings are also relevant to development projects undertaken in other developing countries.

  10. Nutrition and mental performance in children - The NUTRIMENTHE project.

    Science.gov (United States)

    Horton, Claire

    2013-01-01

    The Nutrition And Mental Performance In Children project of the European Union (NUTRIMENTHE) has added to the evidence that maternal diet influences mental performance in childhood. The biological mechanisms have been shown to be complex and to involve genetic variation, as indicated by the work linking genetic variation in the fatty acid desaturase gene cluster to the processing of fatty acids. The role played by a child's diet also needs to be considered and this question is being addressed through the inclusion of post-natal intervention studies in the NUTRIMENTHE project's research plan. This paper summarises progress. © The Author(s) 2013.

  11. Utility of DWI with quantitative ADC values in ovarian tumors: a meta-analysis of diagnostic test performance.

    Science.gov (United States)

    Pi, Shan; Cao, Rong; Qiang, Jin Wei; Guo, Yan Hui

    2018-01-01

    Background Diffusion-weighted imaging (DWI) and quantitative apparent diffusion coefficient (ADC) values are widely used in the differential diagnosis of ovarian tumors. Purpose To assess the diagnostic performance of quantitative ADC values in ovarian tumors. Material and Methods PubMed, Embase, the Cochrane Library, and local databases were searched for studies assessing ovarian tumors using quantitative ADC values. We quantitatively analyzed the diagnostic performances for two clinical problems: benign vs. malignant tumors and borderline vs. malignant tumors. We evaluated diagnostic performances by the pooled sensitivity and specificity values and by summary receiver operating characteristic (SROC) curves. Subgroup analyses were used to analyze study heterogeneity. Results From the 742 studies identified in the search results, 16 studies met our inclusion criteria. A total of ten studies evaluated malignant vs. benign ovarian tumors and six studies assessed malignant vs. borderline ovarian tumors. Regarding the diagnostic accuracy of quantitative ADC values for distinguishing between malignant and benign ovarian tumors, the pooled sensitivity and specificity values were 0.91 and 0.91, respectively. The area under the SROC curve (AUC) was 0.96. For differentiating borderline from malignant tumors, the pooled sensitivity and specificity values were 0.89 and 0.79, and the AUC was 0.91. The methodological quality of the included studies was moderate. Conclusion Quantitative ADC values could serve as useful preoperative markers for predicting the nature of ovarian tumors. Nevertheless, prospective trials focused on standardized imaging parameters are needed to evaluate the clinical value of quantitative ADC values in ovarian tumors.

  12. Performance of consultants on government projects in ghana: Client and contractor pespective

    Directory of Open Access Journals (Sweden)

    J. Dadzie

    2013-07-01

    Full Text Available Construction project consultants share the characteristics of helping their clients address problems and improve upon project performance; they have a passion for the wisdom and expertise they bring to the project, and they have the ability to galvanize clients into action. However, it is an open secret that many projects often delay. Also, it is a known fact that most project contract figures swell more than double the original tender figure. Meanwhile, there are supervising consultants who are engaged and paid to manage such important projects. Their role however, is to complement the effort of contractors to ensure a successful completion of a project. The aim of this research is to identify factors affecting the performance of consultants on government projects, and to rank these factors according to their relative importance from the perspective of consultants. Analysis of the factors considered in a survey indicate that the main factors negatively affecting the performance of consultants are: urgency of the project at hand, project duration, variations, political influence from higher authority, timely decision making on the part of the consulting team and the experience of the design team on the project. The others are the ability of the consultants to work as a team, creativity on the part of the consultants in controlling cost and developing own efficiencies so that contract sums are kept within budget .

  13. The effect of question format and task difficulty on reasoning strategies and diagnostic performance in Internal Medicine residents.

    Science.gov (United States)

    Heemskerk, Laura; Norman, Geoff; Chou, Sophia; Mintz, Marcy; Mandin, Henry; McLaughlin, Kevin

    2008-11-01

    Previous studies have suggested an association between reasoning strategies and diagnostic success, but the influence on this relationship of variables such as question format and task difficulty, has not been studied. Our objective was to study the association between question format, task difficulty, reasoning strategies and diagnostic success. Study participants were 13 Internal Medicine residents at the University of Calgary. Each was given eight problem-solving questions in four clinical presentations and were randomized to groups that differed only in the question format, such that a question presented as short answer (SA) to the first group was presented as extended matching (EM) to the second group. There were equal numbers of SA/EM questions and straightforward/difficult tasks. Participants performed think-aloud during diagnostic reasoning. Data were analyzed using multiple logistic regression. Question format was associated with reasoning strategies; hypothetico-deductive reasoning being used more frequently on EM questions and scheme-inductive reasoning on SA questions. For SA question, non-analytic reasoning alone was used more frequently to answer straightforward cases than difficult cases, whereas for EM questions no such association was observed. EM format and straightforward task increased the odds of diagnostic success, whereas hypothetico-deductive reasoning was associated with reduced odds of success. Question format and task difficulty both influence diagnostic reasoning strategies and studies that examine the effect of reasoning strategies on diagnostic success should control for these effects. Further studies are needed to investigate the effect of reasoning strategies on performance of different groups of learners.

  14. Critical success factors influencing the performance of development projects: An empirical study of Constituency Development Fund projects in Kenya

    OpenAIRE

    Debadyuti Das; Christopher Ngacho

    2017-01-01

    The present work attempts to identify critical success factors (CSFs) influencing the performance of development projects based on their key performance indicators (KPIs). It has considered the case of Constituency Development Fund (CDF) projects constructed between 2003 and 2011 in Kenya and secured the perceptions of 175 respondents comprising clients, consultants and contractors involved in the implementation of CDF projects on 30 success variables. Findings reveal that individual items co...

  15. Preclinical study of diagnostic performances of contrast-enhanced spectral mammography versus MRI for breast diseases in China.

    Science.gov (United States)

    Wang, Qingguo; Li, Kangan; Wang, Lihui; Zhang, Jianbing; Zhou, Zhiguo; Feng, Yan

    2016-01-01

    To evaluate diagnostic performances of CESM for breast diseases with comparison to breast MRI in China. Sixty-eight patients with 77 breast lesions underwent MR and CESM. Two radiologists interpreted either MRI or CESM images, separately and independently. BI-RADS 1-3 and BI-RADS 4-5 were classified into the suspicious benign and suspicious malignant groups. Diagnostic accuracy parameters were calculated. Receiver operating characteristic (ROC) curves were constructed for the two modalities. The agreement and correlation between maximum lesion diameter based on CESM and MRI, or CESM and pathology were analyzed. Diagnostic accuracy parameters for CESM were sensitivity 95.8 %, specificity 65.5 %, PPV 82.1 %, NPV 90.5 % and accuracy 84.4 %. The diagnostic accuracy parameters for breast MRI were sensitivity 93.8 %, specificity 82.8 %, PPV 88.2 %, NPV 92.3 %and accuracy 89.6 %. Area under the curve (AUC) of ROC was 0.96 for breast MRI and 0.88 for CESM. The Bland-Altman plots showed a mean difference of 0.7 mm with 95 % limits of agreement of 11.4 mm in tumor diameter measured using CESM and breast MRI. The differences of size measurement between CESM and breast MRI were significant, whereas no difference was observed between CESM and pathology as well as between breast MRI and pathology. The better correlation with pathological results was found in CESM than breast MRI. Our study demonstrates that CESM possesses better diagnostic performances than breast MRI in terms of diagnostic sensitivity and lesion size assessment. And CESM is a good alternative method of screening breast cancer in high-risk people.

  16. CT-guided transthoracic core needle biopsy for small pulmonary lesions: diagnostic performance and adequacy for molecular testing.

    Science.gov (United States)

    Tian, Panwen; Wang, Ye; Li, Lei; Zhou, Yongzhao; Luo, Wenxin; Li, Weimin

    2017-02-01

    Computed tomography (CT)-guided transthoracic needle biopsy is a well-established, minimally invasive diagnostic tool for pulmonary lesions. Few large studies have been conducted on the diagnostic performance and adequacy for molecular testing of transthoracic core needle biopsy (TCNB) for small pulmonary lesions. This study included CT-guided TCNB with 18-gauge cutting needles in 560 consecutive patients with small (≤3 cm) pulmonary lesions from January 2012 to January 2015. There were 323 males and 237 females, aged 51.8±12.7 years. The size of the pulmonary lesions was 1.8±0.6 cm. The sensitivity, specificity, accuracy and complications of the biopsies were investigated. The risk factors of diagnostic failure were assessed using univariate and multivariate analyses. The sample's adequacy for molecular testing of non-small cell lung cancer (NSCLC) was analyzed. The overall sensitivity, specificity, and accuracy for diagnosis of malignancy were 92.0% (311/338), 98.6% (219/222), and 94.6% (530/560), respectively. The incidence of bleeding complications was 22.9% (128/560), and the incidence of pneumothorax was 10.4% (58/560). Logistic multivariate regression analysis showed that the independent risk factors for diagnostic failure were a lesion size ≤1 cm [odds ratio (OR), 3.95; P=0.007], lower lobe lesions (OR, 2.83; P=0.001), and pneumothorax (OR, 1.98; P=0.004). Genetic analysis was successfully performed on 95.45% (168/176) of specimens diagnosed as NSCLC. At least 96.8% of samples with two or more passes from a lesion were sufficient for molecular testing. The diagnostic yield of small pulmonary lesions by CT-guided TCNB is high, and the procedure is relatively safe. A lesion size ≤1 cm, lower lobe lesions, and pneumothorax are independent risk factors for biopsy diagnostic failure. TCNB specimens could provide adequate tissues for molecular testing.

  17. Target Diagnostics Supports NIF's Path to Ignition

    International Nuclear Information System (INIS)

    Shelton, R.

    2011-01-01

    The physics requirements derived from the National Ignition Facility (NIF) experimental campaigns are leading to a wide variety of target diagnostics. Software development for the control and analysis of these diagnostics is included in the NIF Integrated Computer Control System, Diagnostic Control System and Data Visualization. These projects implement the configuration, controls, data analysis and visual representation of most of these diagnostics. To date, over 40 target diagnostics have been developed to support NIF experiments. In 2011 diagnostics were developed or enhanced to measure Ignition performance in a high neutron yield environment. Performance is optimized around four key variables: Adiabat (a) which is the strength and timing of four shocks delivered to the target, Velocity (V) of the imploding target, Mix (M) is the uniformity of the burn, and the Shape (S) of the imploding Deuterium Tritium (DT) hot spot. The diagnostics used to measure each of these parameters is shown in figure 1. Adiabat is measured using the Velocity Interferometer System for Any Reflector (VISAR) diagnostic consisting of three streak cameras. To provide for more accurate adiabat measurements the VISAR streak cameras were enhanced in FY11 with a ten comb fiducial signal controller to allow for post shot correction of the streak camera sweep non-linearity. Mix is measured by the Neutron Time of Flight (NTOF) and Radiochemical Analysis of Gaseous Samples (RAGS) diagnostics. To accommodate high neutron yield shots, NTOF diagnostic controls are being modified to use Mach Zehnder interferometer signals to allow the digitizers to be moved from near the target chamber to the neutron shielded diagnostic mezzanine. In December 2011 the first phase of RAGS diagnostic commissioning will be completed. This diagnostic will analyze the tracers that are added to NIF target capsules that undergo nuclear reactions during the shot. These gases are collected and purified for nuclear counting by

  18. Comparative analysis of diagnostic performance, feasibility and cost of different test-methods for thyroid nodules with indeterminate cytology.

    Science.gov (United States)

    Sciacchitano, Salvatore; Lavra, Luca; Ulivieri, Alessandra; Magi, Fiorenza; De Francesco, Gian Paolo; Bellotti, Carlo; Salehi, Leila B; Trovato, Maria; Drago, Carlo; Bartolazzi, Armando

    2017-07-25

    Since it is impossible to recognize malignancy at fine needle aspiration (FNA) cytology in indeterminate thyroid nodules, surgery is recommended for all of them. However, cancer rate at final histology is blood assay.We performed systematic reviews and meta-analyses to compare their features, feasibility, diagnostic performance and cost. GEC, GEC+BRAF, M/F panel+miRNA GEC and M/F panel by NGS were the best in ruling-out malignancy (sensitivity = 90%, 89%, 89% and 90% respectively). BRAF and M/F panel alone and by NGS were the best in ruling-in malignancy (specificity = 100%, 93% and 93%). The M/F by NGS showed the highest accuracy (92%) and BRAF the highest diagnostic odds ratio (DOR) (247). GAL-3-ICC performed well as rule-out (sensitivity = 83%) and rule-in test (specificity = 85%), with good accuracy (84%) and high DOR (27) and is one of the cheapest (113 USD) and easiest one to be performed in different clinical settings.In conclusion, the more accurate molecular-based test-methods are still expensive and restricted to few, highly specialized and centralized laboratories. GAL-3-ICC, although limited by some false negatives, represents the most suitable screening test-method to be applied on a large-scale basis in the diagnostic algorithm of indeterminate thyroid lesions.

  19. Social anxiety disorder diagnostic criteria perform equally across age, comorbid diagnosis, and performance/interaction subtypes.

    Science.gov (United States)

    Crome, Erica; Baillie, Andrew

    2015-01-01

    The prevalence of social anxiety disorder (SAD) is frequently higher in younger age groups and people with other anxiety or mood disorders; however, it is unclear whether these groups have a higher risk for developing SAD or are simply more likely to endorse diagnostic criteria than other people with similar levels of social anxiety. Explicitly testing the assumption all people respond to structured diagnostic interviews in comparable ways (measurement invariance) is essential in ensuring systematic response biases do not create spurious group differences. This research aims to systematically test whether age, comorbidity status, or types of social fears affect responses to a structured diagnostic interview. Responses from 1755 participants in a large-scale survey of mental health in Australia screening into the social phobia/SAD section of the Composite International Diagnostic Interview were used. Three series of multigroup confirmatory factor analyses for categorical data systematically tested for increasingly strict levels of measurement invariance. Overall, patterns of responding to diagnostic criteria were comparable across the groups, supporting assumptions of measurement invariance. Establishment of invariance supports the interpretation of differences between age, comorbidity status, and types of social situations feared as genuine differences in experience as opposed to measurement biases.

  20. The Groundwater Performance Assessment Project Quality Assurance Plan

    International Nuclear Information System (INIS)

    Luttrell, Stuart P.

    2006-01-01

    U.S. Department of Energy (DOE) has monitored groundwater on the Hanford Site since the 1940s to help determine what chemical and radiological contaminants have made their way into the groundwater. As regulatory requirements for monitoring increased in the 1980s, there began to be some overlap between various programs. DOE established the Groundwater Performance Assessment Project (groundwater project) in 1996 to ensure protection of the public and the environment while improving the efficiency of monitoring activities. The groundwater project is designed to support all groundwater monitoring needs at the site, eliminate redundant sampling and analysis, and establish a cost-effective hierarchy for groundwater monitoring activities. This document provides the quality assurance guidelines that will be followed by the groundwater project. This QA Plan is based on the QA requirements of DOE Order 414.1C, Quality Assurance, and 10 CFR 830, Subpart A--General Provisions/Quality Assurance Requirements as delineated in Pacific Northwest National Laboratory's Standards-Based Management System. In addition, the groundwater project is subject to the Environmental Protection Agency (EPA) Requirements for Quality Assurance Project Plans (EPA/240/B-01/003, QA/R-5). The groundwater project has determined that the Hanford Analytical Services Quality Assurance Requirements Documents (HASQARD, DOE/RL-96-68) apply to portions of this project and to the subcontractors. HASQARD requirements are discussed within applicable sections of this plan

  1. Diagnostic mirrors for ITER: A material choice and the impact of erosion and deposition on their performance

    International Nuclear Information System (INIS)

    Litnovsky, A.; Wienhold, P.; Philipps, V.; Sergienko, G.; Schmitz, O.; Kirschner, A.; Kreter, A.; Droste, S.; Samm, U.; Mertens, Ph.; Donne, A.H.; Rudakov, D.; Allen, S.; Boivin, R.; McLean, A.; Stangeby, P.; West, W.; Wong, C.; Lipa, M.; Schunke, B.; De Temmerman, G.; Pitts, R.; Costley, A.; Voitsenya, V.; Vukolov, K.; Oelhafen, P.; Rubel, M.; Romanyuk, A.

    2007-01-01

    Metal mirrors will be implemented in about half of the ITER diagnostics. Mirrors in ITER will have to withstand radiation loads, erosion by charge-exchange neutrals, deposition of impurities, particle implantation and neutron irradiation. It is believed that the optical properties of diagnostic mirrors will be primarily influenced by erosion and deposition. A solution is needed for optimal performance of mirrors in ITER throughout the entire lifetime of the machine. A multi-machine research on diagnostic mirrors is currently underway in fusion facilities at several institutions and laboratories worldwide. Among others, dedicated investigations of ITER-candidate mirror materials are ongoing in Tore-Supra, TEXTOR, DIII-D, TCV, T-10 and JET. Laboratory studies are underway at IPP Kharkov (Ukraine), Kurchatov Institute (Russia) and the University of Basel (Switzerland). An overview of current research on diagnostic mirrors along with an outlook on future investigations is the subject of this paper

  2. Diagnostic performance of major depression disorder case-finding instruments used among mothers of young children in the United States: A systematic review.

    Science.gov (United States)

    Owora, Arthur H; Carabin, Hélène; Reese, Jessica; Garwe, Tabitha

    2016-09-01

    Growing recognition of the interrelated negative outcomes associated with major depression disorder (MDD) among mothers and their children has led to renewed public health interest in the early identification and treatment of maternal MDD. Healthcare providers, however, remain unsure of the validity of existing case-finding instruments. We conducted a systematic review to identify the most valid maternal MDD case-finding instrument used in the United States. We identified articles reporting the sensitivity and specificity of MDD case-finding instruments based on Diagnostic and Statistical Manual of Mental Disorders, Fourth Edition (DSM-IV) by systematically searching through three electronic bibliographic databases, PubMed, PsycINFO, and EMBASE, from 1994 to 2014. Study eligibility and quality were evaluated using the Standards for the Reporting of Diagnostic Accuracy studies and Quality Assessment of Diagnostic Accuracy Studies guidelines respectively. Overall, we retrieved 996 unduplicated articles and selected 74 for full-text review. Of these, 14 articles examining 21 different instruments were included in the systematic review. The 10 item Edinburgh Postnatal Depression Scale and Postpartum Depression Screening Scale had the most stable (lowest variation) and highest diagnostic performance during the antepartum and postpartum periods (sensitivity range: 0.63-0.94 and 0.67-0.95; specificity range: 0.83-0.98 and 0.68-0.97 respectively). Greater variation in diagnostic performance was observed among studies with higher MDD prevalence. Factors that explain greater variation in instrument diagnostic performance in study populations with higher MDD prevalence were not examined. Findings suggest that the diagnostic performance of maternal MDD case-finding instruments is peripartum period-specific. Published by Elsevier B.V.

  3. Evaluation performance of diagnostic methods of intestinal parasitosis in school age children in Ethiopia.

    Science.gov (United States)

    Yimer, Mulat; Hailu, Tadesse; Mulu, Wondemagegn; Abera, Bayeh

    2015-12-26

    Although the sensitivity of Wet mount technique is questionable, it is the major diagnostic technique for routine diagnosis of intestinal parasitosis in Ethiopia. Therefore, the aim of this study was the evaluation performance of diagnostic methods of intestinal parasitosis in school age children in Ethiopia. A cross sectional study was conducted from May to June 2013. Single stool sample was processed for direct, Formol ether concentration (FEC) and Kato Katz methods. The sensitivity and negative predictive value (NPV) of diagnostic tests were calculated in terms of the "Gold" standard method (the combined result of the three methods altogether). A total of 422 school age children were participated in this study. The prevalence of intestinal parasites was high (74.6%) with Kato Katz technique. The sensitivity of Wet mount, FEC and Kato Katz tests against the Gold standard test was 48.9, 63.1 and 93.7%, respectively. Kato Katz technique revealed a better NPV 80.4 (80.1-80.6) as compared to the Wet mount (33.7%) and FEC techniques (41.3%). In this study, the Kato Katz technique outperformed the other two methods but the true values for sensitivity, specificity and diagnostic values are not known. Moreover, it is labor intensive and not easily accessible. Hence, it is preferable to use FEC technique to complement the Wet mount test.

  4. Diagnostic performance of sonoelastographic Tsukuba score and strain ratio in evaluation of breast masses

    Directory of Open Access Journals (Sweden)

    Mahmoud Abd Elaziz Dawood

    2018-03-01

    Full Text Available The aim of this prospective study was to evaluate the diagnostic performance of the use of strain index ratio by sonoelastography to differentiate between benign and malignant breast lesions. Patients & Methods: This prospective study including 40 females, complaining of breast masses which were suspicious to be malignant on clinical examination. All patients were submitted to B-mode Ultrasound and sonoelastography. Biopsy as a gold standard and pathological study were done for all breast lesions. Results: US examination of every mass was done and categorized according to BI-RADS categories according to ACR2013, according to US lexicon. Sonoelastography examination with Lesions classification was performed on the basis of a 5-point scoring method proposed by Tsukuba elasticity score. Then measurements of strain ratio were done. Statistical analysis of combination of the three methods was sensitivity of 96.7%, specificity of 100% when we use cut off value of 3–4 in elastography score and ≤3 cut off value of strain ratio. Conclusion: The combined use of strain ratio with Tsukuba score and BI-RADS categorization increased the diagnostic performance in differentiation between benign and malignant breast lesions. Keywords: Elastography, Breast masses, Strain ratio, Ultrasound, BI-RADS classification, Tsukuba score

  5. Diagnostic performance of Contrast-enhanced CT in Pyrrolizidine Alkaloids-induced Hepatic Sinusoidal Obstructive Syndrome

    Science.gov (United States)

    Kan, Xuefeng; Ye, Jin; Rong, Xinxin; Lu, Zhiwen; Li, Xin; Wang, Yong; Yang, Ling; Xu, Keshu; Song, Yuhu; Hou, Xiaohua

    2016-01-01

    Hepatic sinusoidal obstruction syndrome (HSOS) can be caused by pyrrolizidine alkaloids(PAs)-containing herbals. Since PAs exposure is obscure and clinical presentation of HSOS is unspecific, it is challenge to establish the diagnosis of PAs-induced HSOS. Gynura segetum is one of the most wide-use herbals containing PAs. The aim of our study is to describe the features of contrast-enhanced computed tomography (CT) in gynura segetum-induced HSOS, and then determine diagnostic performance of radiological signs. We retrospectively analyzed medical records and CT images of HSOS patients (71 cases) and the controls (222 cases) enrolled from January 1, 2008, to Oct 31, 2015. The common findings of contrast CT in PAs-induced HSOS included: ascites (100%), hepatomegaly (78.87%), gallbladder wall thickening (86.96%), pleural effusion (70.42%), hepatic vein narrowing (87.32%), patchy liver enhancement (92.96%), and heterogeneous hypoattenuation (100%); of these signs, patchy enhancement and heterogeneous hypoattenuation were valuable features. Then, the result of diagnostic performance demonstrated that contrast CT possessed better performance in diagnosing PAs-induced HSOS compared with various parameters of Seattle criteria. In conclusion, the patients with PAs-induced HSOS display distinct radiologic features at CT-scan, which reveals that contrast-enhanced CT provides an effective noninvasive method for diagnosing PAs-induced HSOS. PMID:27897243

  6. Real-Time Projection-Based Augmented Reality System for Dynamic Objects in the Performing Arts

    Directory of Open Access Journals (Sweden)

    Jaewoon Lee

    2015-02-01

    Full Text Available This paper describes the case study of applying projection-based augmented reality, especially for dynamic objects in live performing shows, such as plays, dancing, or musicals. Our study aims to project imagery correctly inside the silhouettes of flexible objects, in other words, live actors or the surface of actor’s costumes; the silhouette transforms its own shape frequently. To realize this work, we implemented a special projection system based on the real-time masking technique, that is to say real-time projection-based augmented reality system for dynamic objects in performing arts. We installed the sets on a stage for live performance, and rehearsed particular scenes of a musical. In live performance, using projection-based augmented reality technology enhances technical and theatrical aspects which were not possible with existing video projection techniques. The projected images on the surfaces of actor’s costume could not only express the particular scene of a performance more effectively, but also lead the audience to an extraordinary visual experience.

  7. How does technological regime affect performance of technology development projects?

    NARCIS (Netherlands)

    Song, Michael; Hooshangi, Soheil; Zhao, Y. Lisa; Halman, Johannes I.M.

    2014-01-01

    In this study, we examine how technological regime affects the performance of technology development projects (i.e., project quality, sales, and profit). Technological regime is defined as the set of attributes of a technological environment where the innovative activities of firms take place.

  8. Performance-based procurement for low disturbance brdige construction projects

    NARCIS (Netherlands)

    Sebastian, R.; Claeson-Jonsson, C.; Di Giulio, R.

    2013-01-01

    Purpose – This paper aims to introduce a method of performance-based procurement, based on the most economically advantageous tender (MEAT), for low-disturbance bridge construction projects in urban environment. Design/methodology/approach – The first part of this paper reviews the key performance

  9. The Atmospheric Chemistry and Climate Model Intercomparison Project (ACCMIP): Overview and Description of Models, Simulations and Climate Diagnostics

    Science.gov (United States)

    Lamarque, J.-F.; Shindell, D. T.; Naik, V.; Plummer, D.; Josse, B.; Righi, M.; Rumbold, S. T.; Schulz, M.; Skeie, R. B.; Strode, S.; hide

    2013-01-01

    The Atmospheric Chemistry and Climate Model Intercomparison Project (ACCMIP) consists of a series of time slice experiments targeting the long-term changes in atmospheric composition between 1850 and 2100, with the goal of documenting composition changes and the associated radiative forcing. In this overview paper, we introduce the ACCMIP activity, the various simulations performed (with a requested set of 14) and the associated model output. The 16 ACCMIP models have a wide range of horizontal and vertical resolutions, vertical extent, chemistry schemes and interaction with radiation and clouds. While anthropogenic and biomass burning emissions were specified for all time slices in the ACCMIP protocol, it is found that the natural emissions are responsible for a significant range across models, mostly in the case of ozone precursors. The analysis of selected present-day climate diagnostics (precipitation, temperature, specific humidity and zonal wind) reveals biases consistent with state-of-the-art climate models. The model-to- model comparison of changes in temperature, specific humidity and zonal wind between 1850 and 2000 and between 2000 and 2100 indicates mostly consistent results. However, models that are clear outliers are different enough from the other models to significantly affect their simulation of atmospheric chemistry.

  10. Magnetic resonance imaging and magnetic resonance arthrography of the shoulder: dependence on the level of training of the performing radiologist for diagnostic accuracy

    Energy Technology Data Exchange (ETDEWEB)

    Theodoropoulos, John S. [University of Toronto, Division of Orthopaedics, Mount Sinai Hospital and the University Health Network, Toronto, ON (Canada); Andreisek, Gustav [University of Toronto, Department of Medical Imaging, Mount Sinai Hospital and the University Health Network, Toronto, ON (Canada); University Hospital Zuerich, Institute for Diagnostic Radiology, Zuerich (Switzerland); Harvey, Edward J. [McGill University, Division of Orthopaedics, MUHC - Montreal General Hospital, Montreal, Quebec (Canada); Wolin, Preston [Center for Athletic Medicine, Chicago, IL (United States)

    2010-07-15

    Discrepancies were identified between magnetic resonance (MR) imaging and clinical findings in patients who had MR imaging examinations evaluated by community-based general radiologists. The purpose of this study was to evaluate the diagnostic performance of MR imaging examinations of the shoulder with regard to the training level of the performing radiologist. A review of patient charts identified 238 patients (male/female, 175/63; mean age, 40.4 years) in whom 250 arthroscopies were performed and who underwent MR imaging or direct MR arthrography in either a community-based or hospital-based institution prior to surgery. All MR imaging and surgical reports were reviewed and the diagnostic performance for the detection of labral, rotator cuff, biceps, and Hill-Sachs lesions was determined. Kappa and Student's t test analyses were performed in a subset of cases in which initial community-based MR images were re-evaluated by hospital-based musculoskeletal radiologists, to determine the interobserver agreement and any differences in image interpretation. The diagnostic performance of community-based general radiologists was lower than that of hospital-based sub-specialized musculoskeletal radiologists. A sub-analysis of re-evaluated cases showed that musculoskeletal radiologists performed better. {kappa} values were 0.208, 0.396, 0.376, and 0.788 for labral, rotator cuff, biceps, and Hill-Sachs lesions (t test statistics: p =<0.001, 0.004, 0.019, and 0.235). Our results indicate that the diagnostic performance of MR imaging and MR arthrography of the shoulder depends on the training level of the performing radiologist, with sub-specialized musculoskeletal radiologists having a better diagnostic performance than general radiologists. (orig.)

  11. The indication area of a diagnostic test. Part I--discounting gain and loss in diagnostic certainty

    NARCIS (Netherlands)

    Stalpers, Lukas J. A.; Nelemans, Patty J.; Geurts, Sandra M. E.; Jansen, Erik; de Boer, Peter; Verbeek, André L. M.

    2015-01-01

    Test performance is conventionally expressed by gain in diagnostic certainty. We propose net diagnostic gain and indication area as more appropriate measures of test performance; then, the loss in certainty due to misclassification and the information of "no test" would be performed are taken into

  12. Comparative diagnostic performance of multidetector computed tomography and MRI for characterization of pancreatic cystic lesions

    International Nuclear Information System (INIS)

    Moon, Sung Min; Shin, Sang Soo; Park, Jin Gyoon; Jeong, Yong Yeon

    2015-01-01

    To compare the diagnostic performance of multidetector computed tomography (MDCT) and magnetic resonance imaging (MRI) in characterization of pancreatic cystic lesions. We conducted a retrospective study on 34 patients with histopathologically proven cystic pancreatic lesions who underwent both preoperative MDCT and MRI. CT and MRI were independently evaluated for differentiating mucinous vs. non-mucinous lesions, differentiating aggressive vs. non-aggressive lesion, analyzing morphological features, and evaluating specific leading diagnoses. Sensitivity, specificity, and accuracy were determined. Competency assessment of lesional morphology analysis was performed using the kappa values of the 2 tests. The sensitivity, specificity, and accuracy of MRI for differentiating mucinous vs. non-mucinous lesions were higher than CT (p = 0.03). For differentiating aggressiveness, the sensitivity of MRI was better than CT, but the specificity of CT was better than MRI. In evaluation of morphologic features, MRI showed better performance in characterization of septa and wall. Otherwise, the 2 modalities showed similarly good performance. MRI was better than CT in determining a specific diagnosis (58.8% vs. 47.2%, respectively). CT and MRI are reasonable diagnostic methods for characterization of pancreatic cystic lesions. However, MRI enables more confident assessment than CT in differentiating mucinous vs. non-mucinous lesions and characterization of the septa and wall

  13. Malignant renal cysts: Diagnostic performance and strong predictors at MDCT

    International Nuclear Information System (INIS)

    Kim, Dae Yoon; Kim, Jeong Kon; Cho, Kyoung-Sik; Min, Gyeong-Eun; Ahn, Han-Jong

    2010-01-01

    Background: Utilization of multidetector-row CT (MDCT) is anticipated to improve the diagnostic accuracy and reliability for determining malignant cysts. Purpose: To assess the diagnostic accuracy, interobserver agreement, benefit of consensus reading, and strong predictors of malignancy in determining malignant cystic renal masses at MDCT. Material and Methods: Two radiologists independently rated the probability of malignancy at MDCT in 72 benign and 53 malignant cysts. The accuracy and interobserver agreement for determining malignant cysts were evaluated. The strong predictors of malignancy were determined, and in patients with interobserver disagreement for determining malignant cysts, consensus readings were performed. Results: Az value of the two readers was 0.905-0.936 and the sensitivity and specificity were 85-89% and 83-93%, respectively. The overall interobserver agreement for determining the malignant cyst was good as the κ value was 0.696 (% agreement, 61% (76/125)). Thickened irregular wall, thickened irregular septa, and enhancing soft tissue component were strong predictors for malignancy with both readers. In the 17 patients with interobserver disagreement for determining malignant cysts, the sensitivity was improved from 38-63% to 89% by the consensus reading. Conclusion: At MDCT, some false negative decisions for determining malignant cysts can be corrected by consensus reading, and thickened irregular septa, thickened irregular wall, and enhancing soft tissue component are the strong predictors of malignant cysts

  14. Prevalence and diagnostic performance of computed tomography angiography spot sign for intracerebral hematoma expansion depend on scan timing

    Energy Technology Data Exchange (ETDEWEB)

    Tsukabe, Akio; Watanabe, Yoshiyuki; Tanaka, Hisashi; Kunitomi, Yuki; Nishizawa, Mitsuo; Arisawa, Atsuko; Tomiyama, Noriyuki [Osaka University Graduate School of Medicine, Department of Diagnostic and Interventional Radiology, Suita, Osaka (Japan); Yoshiya, Kazuhisa; Shimazu, Takeshi [Osaka University Graduate School of Medicine, Department of Traumatology and Acute Critical Medicine, Suita, Osaka (Japan)

    2014-12-15

    The computed tomography angiography (CTA) spot sign correlates with intracerebral hemorrhage (ICH) expansion; however, various diagnostic performances for hematoma expansion, especially in sensitivity, have been reported. We aimed to assess the impact of scan timing of CTA on the diagnostic performance of the CTA spot sign for ICH expansion in two different arterial phases within patients. Eighty-three consecutive patients with primary ICH who received two sequential CTAs were recruited. Two neuroradiologists reviewed CTAs for CTA spot signs, while one reviewed initial and follow-up non-contrast CT for measuring ICH volume. The time interval between two phases was then calculated, and the diagnostic performance of CTA spot sign in each phase was evaluated. CTA spot signs were observed in 20/83 (24.1 %) patients in the early phase and 44/83 (53.0 %) patients in the late phase. The mean time interval between the two phases was 12.7 s. Sensitivity, specificity, positive predictive value, negative predictive value, and accuracy for hematoma progression of CTA spot sign were 48.1, 87.5, 65.0, 77.8, and 74.7 %, respectively, in early phase and 92.6, 66.1, 56.8, 94.9, and 74.7 %, respectively, in late phase. The CTA spot sign was significantly associated with ICH expansion in early (P < 0.001) and late (P < 0.00001) phases (Pearson's chi-square test). A mere 10-s difference in scan timing could make a difference on prevalence and diagnostic performance of the CTA spot sign, suggesting a need for the standardization of the CTA protocol to generalize the approach for effective clinical application. (orig.)

  15. LHD neutron diagnostics

    International Nuclear Information System (INIS)

    Isobe, M.; Ogawa, K.; Kobuchi, T.

    2015-01-01

    The Large Helical Device (LHD) project will step into a next stage, i.e. experiment by using deuterium gases after two years of preparation. A comprehensive set of neutron and γ-ray diagnostics is going to be installed on the LHD towards extension of energetic-particle (EP) physics research in heliotron plasmas. Conceptual design of fusion products diagnostics for the LHD was made in late 1990s. After conclusion of agreements for the LHD deuterium experiment with local government bodies, development of FPs diagnostics has begun lately. Because there are a lot of tasks to do, all Japan fusion neutron and γ-ray diagnostics team has been organized in the collaboration framework of National Institute for Fusion Science. FPs diagnostics system on the LHD will consist of 1) wide dynamic range neutron flux monitor (NFM), 2) neutron activation system (NAS), 3) vertical neutron camera (VNC). In addition to these, we are developing a directional scintillating fiber detector, an artificial diamond detector and a γ-ray scintillation detector for confinement study of MeV ions. A neutron energy spectrometer prototype is also being developed and tested in KSTAR. In this paper, roles of NFM, NAS and VNC and current status of implementation onto the LHD are briefly described. (author)

  16. MR arthrography in calcific tendinitis of the shoulder: diagnostic performance and pitfalls

    Energy Technology Data Exchange (ETDEWEB)

    Zubler, Christoph; Mengiardi, Bernard; Schmid, Marius R.; Hodler, Juerg; Pfirrmann, Christian W.A. [University Hospital Balgrist, Radiology, Zurich (Switzerland); Jost, Bernhard [University Hospital Balgrist, Orthopedic Surgery, Zurich (Switzerland)

    2007-06-15

    The purpose was to assess the diagnostic performance of MR arthrography to diagnose calcific tendinitis of the shoulder and to assess the reasons for diagnostic errors. Standard MR arthrograms of 22 patients with calcific tendinitis and 61 controls were retrospectively analyzed by two independent and blinded radiologists. All cases were consecutively collected from a database. Conventional radiographs were available in all cases serving as gold standard. The supraspinatus was involved in 16, the infraspinatus in four and the subscapularis in two patients. All diagnostic errors were analyzed by two additional readers. Reader 1 correctly detected 12 of the 22 shoulders with and 42 of the 61 shoulders without calcific tendinitis (sensitivity 0.55, specificity 0.66). The corresponding values for reader 2 were 13 of 22 and 40 of 61 cases (sensitivity 0.59, specificity 0.69). Inter-rater agreement (kappa-value) was 0.42. Small size of the calcific deposits and isointensity compared to the surrounding tissue were the most important reasons for false negative results. Normal hypointense areas within the supraspinatus tendon substance and attachment were the main reason for false positive results. In conclusion, MR arthrography is insufficient in the diagnosis of calcific tendinitis. Normal hypointense parts of the rotator cuff may mimic calcific deposits and calcifications may not be detected when they are isointense compared to the rotator cuff. Therefore, MR imaging should not be interpreted without corresponding radiographs. (orig.)

  17. MR arthrography in calcific tendinitis of the shoulder: diagnostic performance and pitfalls

    International Nuclear Information System (INIS)

    Zubler, Christoph; Mengiardi, Bernard; Schmid, Marius R.; Hodler, Juerg; Pfirrmann, Christian W.A.; Jost, Bernhard

    2007-01-01

    The purpose was to assess the diagnostic performance of MR arthrography to diagnose calcific tendinitis of the shoulder and to assess the reasons for diagnostic errors. Standard MR arthrograms of 22 patients with calcific tendinitis and 61 controls were retrospectively analyzed by two independent and blinded radiologists. All cases were consecutively collected from a database. Conventional radiographs were available in all cases serving as gold standard. The supraspinatus was involved in 16, the infraspinatus in four and the subscapularis in two patients. All diagnostic errors were analyzed by two additional readers. Reader 1 correctly detected 12 of the 22 shoulders with and 42 of the 61 shoulders without calcific tendinitis (sensitivity 0.55, specificity 0.66). The corresponding values for reader 2 were 13 of 22 and 40 of 61 cases (sensitivity 0.59, specificity 0.69). Inter-rater agreement (kappa-value) was 0.42. Small size of the calcific deposits and isointensity compared to the surrounding tissue were the most important reasons for false negative results. Normal hypointense areas within the supraspinatus tendon substance and attachment were the main reason for false positive results. In conclusion, MR arthrography is insufficient in the diagnosis of calcific tendinitis. Normal hypointense parts of the rotator cuff may mimic calcific deposits and calcifications may not be detected when they are isointense compared to the rotator cuff. Therefore, MR imaging should not be interpreted without corresponding radiographs. (orig.)

  18. Prototype of a diagnostic decision support tool for structural damage in masonry

    NARCIS (Netherlands)

    De Vent, I.A.E.

    2011-01-01

    This prototype of a diagnostic decision support tool for structural damage in traditional masonry is the result of a PhD research project. The research project has aimed to improve and facilitate the diagnostic process by offering support in the initial phase in which hypotheses are generated. The

  19. IMPORTANCE OF EARNED VALUE METHOD (EVA IN THE PERFORMANCE ANALYSIS OF PROJECTS

    Directory of Open Access Journals (Sweden)

    MARGARITA JANESKA

    2016-04-01

    Full Text Available The economics of the projects is an important process in the project management. Effective control of projects is based on appropriate methods for monitoring, and the entire project, the timetable, cost, quality and risk. Unlike accounting aspects in project management are looking for information that allow insight into the status and trends of financial progress of the project. Such information provide a method of earned value. It is a key component for assessing the actual performance of the project. The method of earned value is a better indicator of the progress of the project in comparison to the classical method of comparing planned and actual costs. This method shows the profit in relation to actual costs at a specific time point. This method is the basis for calculating the index of the project performance. In this sense, MS Project provides many opportunities for quality control and monitoring of the realization of the projects. In this study will be described the architecture of this method, outlined the benefits of the application of this method, and the basic criteria that should satisfy project management to be able to apply it.

  20. The ATLAS project: The effects of a constructionist digital laboratory project on undergraduate laboratory performance.

    Science.gov (United States)

    Shoepe, Todd C; Cavedon, Dana K; Derian, Joseph M; Levy, Celine S; Morales, Amy

    2015-01-01

    Anatomical education is a dynamic field where developments in the implementation of constructive, situated-learning show promise in improving student achievement. The purpose of this study was to examine the effectiveness of an individualized, technology heavy project in promoting student performance in a combined anatomy and physiology laboratory course. Mixed-methods research was used to compare two cohorts of anatomy laboratories separated by the adoption of a new laboratory atlas project, which were defined as preceding (PRE) and following the adoption of the Anatomical Teaching and Learning Assessment Study (ATLAS; POST). The ATLAS project required the creation of a student-generated, photographic atlas via acquisition of specimen images taken with tablet technology and digital microscope cameras throughout the semester. Images were transferred to laptops, digitally labeled and photo edited weekly, and compiled into a digital book using Internet publishing freeware for final project submission. An analysis of covariance confirmed that student final examination scores were improved (P project (PRE, n = 75; POST, n = 90; means ± SE; 74.9 ± 0.9 versus 78.1 ± 0.8, respectively) after controlling for cumulative student grade point average. Analysis of questionnaires collected (n = 68) from the post group suggested students identified with atlas objectives, appreciated the comprehensive value in final examination preparation, and the constructionism involved, but recommended alterations in assignment logistics and the format of the final version. Constructionist, comprehensive term-projects utilizing student-preferred technologies could be used to improve performance toward student learning outcomes. © 2014 American Association of Anatomists.

  1. Diagnostic Performance of Self-Assessment for Constipation in Patients With Long-Term Opioid Treatment.

    Science.gov (United States)

    Tafelski, Sascha; Bellin, Felicitas; Denke, Claudia; Beutlhauser, Torsten; Fritzsche, Thomas; West, Christina; Schäfer, Michael

    2015-12-01

    Constipation is a prevalent comorbidity affecting ∼50% of patients with long-term opioid therapy. In clinical routine different diagnostic instruments are in use to identify patients under risk. The aim of this study was to assess the diagnostic performance of an 11-item Likert scale for constipation used as a self-assessment in opioid-treated patients. This trial was conducted as a retrospective cohort study in Berlin, Germany. Patients with long-term opioid therapy treated in 2 university-affiliated outpatient pain facilities at the Charité hospital were included from January 2013 to August 2013. Constipation was rated in a self-assessment using a numeric rating scale from 0 to 10 (Con-NRS) and compared with results from a structured assessment based on ROME-III criteria. Altogether, 171 patients were included. Incidence of constipation was 49% of patients. The receiver-operating characteristic of Con-NRS achieved an area under the curve of 0.814 (AUC 95% confidence interval 0.748-0.880, P < 0.001). Con-NRS ≥ 1 achieved sensitivity and specificity of 79.7% and 77.2%, respectively. The positive predictive value and the negative predictive value were 70.3% and 81.6%, respectively. Overall diagnostic performance of a concise 11-item Likert scale for constipation was moderate. Although patients with long-term opioid therapy are familiar with numeric rating scales, a significant number of patients with constipation were not identified. The instrument may be additionally useful to facilitate individualized therapeutic decision making and to control therapeutic success when measured repetitively.

  2. Frequency of chest pain in primary care, diagnostic tests performed and final diagnoses.

    Science.gov (United States)

    Hoorweg, Beatrijs Bn; Willemsen, Robert Ta; Cleef, Lotte E; Boogaerts, Tom; Buntinx, Frank; Glatz, Jan Fc; Dinant, Geert Jan

    2017-11-01

    Observational study of patients with chest pain in primary care: determination of incidence, referral rate, diagnostic tests and (agreement between) working and final diagnoses. 118 general practitioners (GPs) in the Netherlands and Belgium recorded all patient contacts during  2weeks. Furthermore, patients presenting with chest pain were registered extensively. A follow-up form was filled in after 30 days. 22 294 patient contacts were registered. In 281 (1.26%), chest pain was a reason for consulting the GP (mean age for men 54.4/women 53 years). In this cohort of 281 patients, in 38.1% of patients, acute coronary syndrome (ACS) was suspected at least temporarily during consultation, 40.2% of patients were referred to secondary care and 512 diagnostic tests were performed by GPs and consulted specialists. Musculoskeletal pain was the most frequent working (26.1%) and final diagnoses (33.1%). Potentially life-threatening diseases as final diagnosis (such as myocardial infarction) accounted for 8.4% of all chest pain cases. In 23.1% of cases, a major difference between working and final diagnoses was found, in 0.7% a severe disease was initially missed by the GP. Chest pain was present in 281 patients (1.26% of all consultations). Final diagnoses were mostly non-life-threatening. Nevertheless, in 8.4% of patients with chest pain, life-threatening underlying causes were identified. This seems reflected in the magnitude and wide variety of diagnostic tests performed in these patients by GPs and specialists, in the (safe) overestimation of life-threatening diseases by GPs at initial assessment and in the high referral rate we found. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2017. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  3. Volume perfusion CT imaging of cerebral vasospasm: diagnostic performance of different perfusion maps

    Energy Technology Data Exchange (ETDEWEB)

    Othman, Ahmed E. [RWTH Aachen University, Department of Diagnostic and Interventional Neuroradiology, Aachen (Germany); Eberhard Karls University Tuebingen, University Hospital Tuebingen, Department for Diagnostic and Interventional Radiology, Tuebingen (Germany); Afat, Saif; Nikoubashman, Omid; Mueller, Marguerite; Wiesmann, Martin; Brockmann, Carolin [RWTH Aachen University, Department of Diagnostic and Interventional Neuroradiology, Aachen (Germany); Schubert, Gerrit Alexander [RWTH Aachen University, Department of Neurosurgery, Aachen (Germany); Bier, Georg [Eberhard Karls University Tuebingen, University Hospital Tuebingen, Department for Diagnostic and Interventional Neuroradiology, Tuebingen (Germany); Brockmann, Marc A. [RWTH Aachen University, Department of Diagnostic and Interventional Neuroradiology, Aachen (Germany); University Hospital Mainz, Department of Neuroradiology, Mainz (Germany)

    2016-08-15

    In this study, we aimed to evaluate the diagnostic performance of different volume perfusion CT (VPCT) maps regarding the detection of cerebral vasospasm compared to angiographic findings. Forty-one datasets of 26 patients (57.5 ± 10.8 years, 18 F) with subarachnoid hemorrhage and suspected cerebral vasospasm, who underwent VPCT and angiography within 6 h, were included. Two neuroradiologists independently evaluated the presence and severity of vasospasm on perfusion maps on a 3-point Likert scale (0 - no vasospasm, 1 - vasospasm affecting <50 %, 2 - vasospasm affecting >50 % of vascular territory). A third neuroradiologist independently assessed angiography for the presence and severity of vasospasm on a 3-point Likert scale (0 - no vasospasm, 1 - vasospasm affecting < 50 %, 2 - vasospasm affecting > 50 % of vessel diameter). Perfusion maps of cerebral blood volume (CBV), cerebral blood flow (CBF), mean transit time (MTT), and time to drain (TTD) were evaluated regarding diagnostic accuracy for cerebral vasospasm with angiography as reference standard. Correlation analysis of vasospasm severity on perfusion maps and angiographic images was performed. Furthermore, inter-reader agreement was assessed regarding findings on perfusion maps. Diagnostic accuracy for TTD and MTT was significantly higher than for all other perfusion maps (TTD, AUC = 0.832; MTT, AUC = 0.791; p < 0.001). TTD revealed higher sensitivity than MTT (p = 0.007). The severity of vasospasm on TTD maps showed significantly higher correlation levels with angiography than all other perfusion maps (p ≤ 0.048). Inter-reader agreement was (almost) perfect for all perfusion maps (kappa ≥ 0.927). The results of this study indicate that TTD maps have the highest sensitivity for the detection of cerebral vasospasm and highest correlation with angiography regarding the severity of vasospasm. (orig.)

  4. Diagnostic performance of dark-blood T2-weighted CMR for evaluation of acute myocardial injury.

    Science.gov (United States)

    Srichai, Monvadi B; Lim, Ruth P; Lath, Narayan; Babb, James; Axel, Leon; Kim, Daniel

    2013-01-01

    We compared the image quality and diagnostic performance of 2 fat-suppression methods for black-blood T2-weighted fast spin-echo (FSE), which are as follows: (a) short T1 inversion recovery (STIR; FSE-STIR) and (b) spectral adiabatic inversion recovery (SPAIR; FSE-SPAIR), for detection of acute myocardial injury. Edema-sensitive T2-weighted FSE cardiac magnetic resonance (CMR) imaging is useful in detecting acute myocardial injury but may experience reduced myocardial signal and signal dropout. The SPAIR pulse aims to eliminate artifacts associated with the STIR pulse. A total of 65 consecutive patients referred for CMR evaluation of myocardial structure and function underwent FSE-STIR and FSE-SPAIR, in addition to cine and late gadolinium enhancement (LGE) CMR. T2-weighted FSE images were independently evaluated by 2 readers for image quality and artifacts (Likert scale of 1-5; best-worst) and presence of increased myocardial signal suggestive of edema. In addition, clinical CMR interpretation, incorporating all CMR sequences available, was recorded for comparison. Diagnostic performance of each T2-weighted sequence was measured using recent (T2, and wall motion. There was a statistically significant difference in sensitivity between the clinical interpretation and each of the T2-weighted sequences but not between each T2-weighted sequence. Although FSE-SPAIR demonstrated significantly improved image quality and decreased artifacts, isolated interpretations of each T2-weighted technique demonstrated high specificity but overall low sensitivity for the detection of myocardial injury, with no difference in accuracy between the techniques. However, real-world interpretation in combination with cine and LGE CMR methods significantly improves the overall sensitivity and diagnostic performance.

  5. A CONCEPTUAL TOOL FOR ASSESSING CLIENT PERFORMANCE IN THE CONSTRUCTION PROJECT COALITION

    Directory of Open Access Journals (Sweden)

    Gary D. Holt

    2002-01-01

    Full Text Available Due to the significant impact of client performance on overall project performance and the interdependence of participant%5C%27s performance in the construction project coalition %28i.e. clients%2C designers and constructors%29%2C there is a need to establish client performance measures. Based on data collected from in-depth interviews with nineteen UK architects and nine UK contractors%2C a generic tool for the on-going formal assessment of client performance is presented. It was found that this approach to performance assessment %28i.e. from the view point of other%2C non-client coalition participants%29 should lead to improved project relationships. Data analysis showed that in addition to %5C%27harder%5C%27 measures such as understanding of project requirements and finance%2C other%2C %5C%27softer%5C%27 measures of client performance %28e.g. attitude%29 were worthy of consideration since they determine the quality of participant relationships. It is recommended that the tool be used to promote more effective client performance and thus enhance coalition relationships%2C enabling continuous improvement. The ultimate aim is to develop similar tools for the assessment of all coalition participants based on a culture of openness and trust. Abstract in Bahasa Indonesia : assessment+tool%2C+coalition+participants%2C+client+performance%2C+perceptions%2C+performance+measures%2C+satisfaction.

  6. Miniature Biometric Sensor Project

    Science.gov (United States)

    Falker, John; Terrier, Douglas; Clayton, Ronald; Hanson, Andrea; Cooper, Tommy; Downs, Meghan; Flint, Stephanie; Reyna, Baraquiel; Simon, Cory; Wilt, Grier

    2015-01-01

    Heart rate monitoring (HRM) is a critical need during exploration missions. Unlike the four separate systems used on ISS today, the single HRM system should perform as a diagnostic tool, perform well during exercise or high level activity, and be suitable for use during EVA. Currently available HRM technologies are dependent on uninterrupted contact with the skin and are prone to data drop-out and motion artifact when worn in the spacesuit or during exercise. Here, we seek an alternative to the chest strap and electrode based sensors currently in use on ISS today. This project aims to develop a single, high performance, robust biosensor with focused efforts on improved heart rate data quality collection during high intensity activity such as exercise or EVA.

  7. Diagnostic performances of shear wave elastography: which parameter to use in differential diagnosis of solid breast masses?

    Science.gov (United States)

    Lee, Eun Jung; Jung, Hae Kyoung; Ko, Kyung Hee; Lee, Jong Tae; Yoon, Jung Hyun

    2013-07-01

    To evaluate which shear wave elastography (SWE) parameter proves most accurate in the differential diagnosis of solid breast masses. One hundred and fifty-six breast lesions in 139 consecutive women (mean age: 43.54 ± 9.94 years, range 21-88 years), who had been scheduled for ultrasound-guided breast biopsy, were included. Conventional ultrasound and SWE were performed in all women before biopsy procedures. Ultrasound BI-RADS final assessment and SWE parameters were recorded. Diagnostic performance of each SWE parameter was calculated and compared with those obtained when applying cut-off values of previously published data. Performance of conventional ultrasound and ultrasound combined with each parameter was also compared. Of the 156 breast masses, 120 (76.9 %) were benign and 36 (23.1 %) malignant. Maximum stiffness (Emax) with a cut-off of 82.3 kPa had the highest area under the receiver operating characteristics curve (Az) value compared with other SWE parameters, 0.860 (sensitivity 88.9 %, specificity 77.5 %, accuracy 80.1 %). Az values of conventional ultrasound combined with each SWE parameter showed lower (but not significantly) values than with conventional ultrasound alone. Maximum stiffness (82.3 kPa) provided the best diagnostic performance. However the overall diagnostic performance of ultrasound plus SWE was not significantly better than that of conventional ultrasound alone. • SWE offers new information over and above conventional breast ultrasound • Various SWE parameters were explored regarding distinction between benign and malignant lesions • An elasticity of 82.3 kPa appears optimal in differentiating solid breast masses • However, ultrasound plus SWE was not significantly better than conventional ultrasound alone.

  8. Diagnostic performance of computed tomography for parathyroid adenoma localization; a systematic review and meta-analysis

    Energy Technology Data Exchange (ETDEWEB)

    Kluijfhout, Wouter P., E-mail: WPKluijfhout@gmail.com [Department of Surgery, University of California San Francisco (United States); Department of Surgery, University Medical Center Utrecht (Netherlands); Pasternak, Jesse D. [Department of Surgery, University Health Network Toronto (Canada); Beninato, Toni; Drake, Frederick Thurston; Gosnell, Jessica E.; Shen, Wen T.; Duh, Quan-Yang [Department of Surgery, University of California San Francisco (United States); Allen, Isabel E. [Department of Epidemiology and Biostatistics, University of California San Francisco (United States); Vriens, Menno R. [Department of Surgery, University Medical Center Utrecht (Netherlands); Keizer, Bart de [Department of Radiology, University Medical Center Utrecht (Netherlands); Hope, Thomas A. [Department of Radiology, University of California San Francisco (United States); Suh, Insoo [Department of Surgery, University of California San Francisco (United States)

    2017-03-15

    Highlights: • CT performs well in localizing pathological parathyroid glands. • Performance of CT is less in patients with inconclusive ultrasound and sestamibi. • Addition of a third contrast phase seems to have little added value. - Abstract: Abstract purpose: To perform a systematic review and meta-analysis of the sensitivity and positive predictive value (PPV) of CT for preoperative parathyroid localization in patients with primary hyperparathyroidism (pHPT), and subsequently compare the different protocols and their performance in different patient groups. Materials and methods: We performed a search of the Embase, Pubmed and Cochrane Library databases to identify studies published between January 1, 2000 and March 31, 2016 investigating the diagnostic value of CT for parathyroid localization in patients with biochemical diagnosis of pHPT. Performance of CT was expressed in sensitivity and PPV with pooled proportion using a random-effects model. Factors that could have affected the diagnostic performance were investigated by subgroup analysis. Results: Thirty-four studies evaluating a total of 2563 patients with non-familial pHPT who underwent CT localization and surgical resection were included. Overall pooled sensitivity of CT for localization of the pathological parathyroid(s) to the correct quadrant was 73% (95% CI: 69–78%), which increased to 81% (95% CI: 75–87%) for lateralization to the correct side. Subgroup analysis based on the number of contrast phases showed that adding a second contrast phase raises sensitivity from 71% (95% CI: 61–80%) to 76% (95% CI: 71–87%), and that adding a third phase resulted in a more modest additional increase in performance with a sensitivity of 80% (95% CI: 74–86%). Conclusion: CT performs well in localizing pathological glands in patients with pHPT. A protocol with two contrast phases seems to offer a good balance of acceptable performance with limitation of radiation exposure.

  9. Methodology, models and algorithms in thermographic diagnostics

    CERN Document Server

    Živčák, Jozef; Madarász, Ladislav; Rudas, Imre J

    2013-01-01

    This book presents  the methodology and techniques of  thermographic applications with focus primarily on medical thermography implemented for parametrizing the diagnostics of the human body. The first part of the book describes the basics of infrared thermography, the possibilities of thermographic diagnostics and the physical nature of thermography. The second half includes tools of intelligent engineering applied for the solving of selected applications and projects. Thermographic diagnostics was applied to problematics of paraplegia and tetraplegia and carpal tunnel syndrome (CTS). The results of the research activities were created with the cooperation of the four projects within the Ministry of Education, Science, Research and Sport of the Slovak Republic entitled Digital control of complex systems with two degrees of freedom, Progressive methods of education in the area of control and modeling of complex object oriented systems on aircraft turbocompressor engines, Center for research of control of te...

  10. Refining multi-model projections of temperature extremes by evaluation against land-atmosphere coupling diagnostics

    Science.gov (United States)

    Sippel, Sebastian; Zscheischler, Jakob; Mahecha, Miguel D.; Orth, Rene; Reichstein, Markus; Vogel, Martha; Seneviratne, Sonia I.

    2017-05-01

    and present-day climate extremes are affected to a lesser extent by the applied constraint, i.e. projected changes are reduced locally by around 0.5 to 1 °C - but this remains a local effect in regions that are highly sensitive to land-atmosphere coupling. In summary, our approach offers a physically consistent, diagnostic-based avenue to evaluate multi-model ensembles and subsequently reduce model biases in simulated and projected extreme temperatures.

  11. Comparing Performance of Government and Private Clients in Construction Projects: Contractors’ Perspective

    Directory of Open Access Journals (Sweden)

    Jati Utomo Dwi Hatmoko

    2016-09-01

    Full Text Available By nature, government and private projects have different characteristics, which influence client performance. This research aims to compare performance of government and private clients in construction projects as perceived by contractors. Six client performance indicators were used, i.e. understanding of project requirements, financial, decision making, management skills, supports for contractor, and client’s attitude. Data were collected through questionnaire surveys filled in by 117 respondents. The results show that there is a significant difference between both types of client performance. Three variables related to financial indicators, i.e. timely payment, owner value estimate, and payment approval, rank in the bottom three of the government client performance, but in contrast rank in the top three of the private ones. These results suggest that the government clients’ performance is perceived inferior to the private ones. Establishing a clients’ forum for sharing knowledge and best practices would be a strategic solution to enhance clients’ capacities.

  12. Diagnostic performance of combined noninvasive coronary angiography and myocardial perfusion imaging using 320 row detector computed tomography

    DEFF Research Database (Denmark)

    Vavere, Andrea L; Simon, Gregory G; George, Richard T

    2013-01-01

    Multidetector coronary computed tomography angiography (CTA) is a promising modality for widespread clinical application because of its noninvasive nature and high diagnostic accuracy as found in previous studies using 64 to 320 simultaneous detector rows. It is, however, limited in its ability...... to detect myocardial ischemia. In this article, we describe the design of the CORE320 study ("Combined coronary atherosclerosis and myocardial perfusion evaluation using 320 detector row computed tomography"). This prospective, multicenter, multinational study is unique in that it is designed to assess...... the diagnostic performance of combined 320-row CTA and myocardial CT perfusion imaging (CTP) in comparison with the combination of invasive coronary angiography and single-photon emission computed tomography myocardial perfusion imaging (SPECT-MPI). The trial is being performed at 16 medical centers located in 8...

  13. High voltage diagnostics on electrical insulation of supersonducting magnets

    International Nuclear Information System (INIS)

    Irmisch, M.

    1995-12-01

    The high voltage (HV) performance of superconducting magnets of large dimensions, e.g. as needed in fusion reactors, is a challange in the field of high voltage technology, i.e. especially in the field of cryogenic high voltage components and with respect to questions of HV insulation diagnostics at low temperature. By using the development of POLO - a superconducting prototype coil of a tokamak poloidal field coil - as an example, this work deals with special problems of how to get use of conventional HV test techniques for diagnostics under special cryogenic boundary conditions. As a first approach to gain experience in the field of phase resolved partial discharge (PRPD) measurements during operation of a superconductive coil, the POLO coil was subject to several high voltage tests. Compared with DC insulation resistance measurements and capacitive impulse voltage discharges to the coil, the AC PD measurements have been the only way to observe special characteristics of the electrical insulation with respect to the cooling down of the coil from 300 K to 4.2 K. The PRPD measurement technique thereby has proofed as a suitable diagnostic tool. This work can serve as basic data to be comparable within further projects of electrical insulation diagnostics at cryogenic temperatures. (orig.)

  14. Quality control in diagnostic radiology - patient dosimetry

    Energy Technology Data Exchange (ETDEWEB)

    Prlic, I; Radalj, Z; Brumen, V; Cerovac, H [Institute for Medical Research and Occupational Health, Laboratory for Radiation Protection and Dosimetry, Zagreb (Croatia); Gladic, J [Institute for Physics, Laboratory for Solid State Physics, Zagreb (Croatia); Tercek, V [Clinical Hospital Sisters of Mercy, Health Physics Department, Zagreb (Croatia)

    1997-12-31

    In order to establish the Quality Criteria for diagnostic radiographic images in the radiology departments in Republic of Croatia we have started the several Quality Control projects on the field. The measurements are performed according to some methodology recommendations in our law but the methodology, measurement principles, measurement equipment, phantoms, measurable parameters for the good use by radiographers, statistical and numerical evaluation, dosimetric philosophy etc. where first recognized as a private/or group hazard of each person involved in the procedure of evaluation of diagnostic radiology images/diagnosis. The important quality elements of the imaging process are: the diagnostic quality of the radiographic image, the radiation dose to the patient and the choice of the radiographic technique. This depends on the x-ray unit (tube) radiation quality, image processing quality and final image evaluation quality. In this paper we will show how the Quality Control measurements can be easily connected to the dose delivered to the patient for the known diagnostic procedure and how this can be used by radiographers in their daily work. The reproducibility of the x-ray generator was checked before the service calibration and after the service calibration. The table of kV dependence and output dose per mAs was calculated and the ESD (entrance surface dose) was measured/calculated for the specific diagnostic procedure. After the phantom calculation were made and the dose prediction for the given procedure was done, measurements were done on the patients (digital dosemeters, TLD and film dosemeter combinations). We are claiming that there is no need to measure each patient if the proper Quality Control measurements are done and the proper table of ESD for each particular x-ray tube in diagnostic departments is calculated for the radiographers daily use. (author). 1 example, 1 fig., 13 refs.

  15. Comparison of Diagnostic Performance of Semi-Quantitative Knee Ultrasound and Knee Radiography with MRI: Oulu Knee Osteoarthritis Study

    Science.gov (United States)

    Podlipská, Jana; Guermazi, Ali; Lehenkari, Petri; Niinimäki, Jaakko; Roemer, Frank W.; Arokoski, Jari P.; Kaukinen, Päivi; Liukkonen, Esa; Lammentausta, Eveliina; Nieminen, Miika T.; Tervonen, Osmo; Koski, Juhani M.; Saarakkala, Simo

    2016-01-01

    Osteoarthritis (OA) is a common degenerative musculoskeletal disease highly prevalent in aging societies worldwide. Traditionally, knee OA is diagnosed using conventional radiography. However, structural changes of articular cartilage or menisci cannot be directly evaluated using this method. On the other hand, ultrasound is a promising tool able to provide direct information on soft tissue degeneration. The aim of our study was to systematically determine the site-specific diagnostic performance of semi-quantitative ultrasound grading of knee femoral articular cartilage, osteophytes and meniscal extrusion, and of radiographic assessment of joint space narrowing and osteophytes, using MRI as a reference standard. Eighty asymptomatic and 79 symptomatic subjects with mean age of 57.7 years were included in the study. Ultrasound performed best in the assessment of femoral medial and lateral osteophytes, and medial meniscal extrusion. In comparison to radiography, ultrasound performed better or at least equally well in identification of tibio-femoral osteophytes, medial meniscal extrusion and medial femoral cartilage morphological degeneration. Ultrasound provides relevant additional diagnostic information on tissue-specific morphological changes not depicted by conventional radiography. Consequently, the use of ultrasound as a complementary imaging tool along with radiography may enable more accurate and cost-effective diagnostics of knee osteoarthritis at the primary healthcare level. PMID:26926836

  16. Point of Injury Sampling Technology for Battlefield Molecular Diagnostics

    Science.gov (United States)

    2011-11-14

    Injury" Sampling Technology for Battlefield Molecular Diagnostics November 14, 2011 Sponsored by Defense Advanced Research Projects Agency (DOD...Date of Contract: April 25, 2011 Short Title of Work: "Point of Injury" Sampling Technology for Battlefield Molecular Diagnostics " Contract...PHASE I FINAL REPORT: Point of Injury, Sampling Technology for Battlefield Molecular Diagnostics . W31P4Q-11-C-0222 (UNCLASSIFIED) P.I: Bernardo

  17. [Qualitative and quantitative diagnostic performance of 320-slice computed tomography for detecting coronary artery disease with respect to atherosclerotic plaque characteristics].

    Science.gov (United States)

    Li, Suhua; Liu, Jinlai; Peng, Long; Dong, Ruimin; Wu, Huilan; Wang, Chenlin; Ni, Qiongqiong; Luo, Yanting; Zhu, Jieming; Chen, Lin

    2014-10-28

    To investigate qualitatively and quantitatively the diagnostic performance of 320-slice CT for detection of coronary artery disease with respect to different atherosclerotic plaque characteristics. A retrospective search was performed for inpatients underwent both coronary CT and further coronary angiography (CAG) from December 1, 2008 to December 31, 2012. The diagnostic performance of 320-slice CTA for detecting significant stenosis ( ≥ 50% diameter) with respect to atherosclerotic plaque characteristics were analyzed by calculating sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), accuracy, kappa index (κ), and area under the receiver operating characteristic curve (AUC). Chi-square test was used to evaluate whether there were significant differences of the true-case frequency (true positive + true negative) and false-case frequency (false positive + false negative) among groups. Bland-Altman analysis was used to determine limits of agreement between CTA and CAG. A total of 454 patients and 6 779 segments were analyzed. Diagnostic accuracy was higher in non-calcified segments; whereas they decreased in the presence of both mild-moderately and heavily calcified plaques. Excellent agreement (κ = 0.810) between CT and CAG was observed for non-calcified segments, while good agreement was observed for both mild-moderately (κ = 0.701) and heavily calcified segments (κ = 0.750). Both mild-moderate (P = 0.000) and heavy (P = 0.000) calcification decreased the true-case frequency and increased the false-case frequency when compared to non-calcification. There were no significant underestimation or overestimation for non-calcified (P = 0.087) and mild-moderately calcified (P = 0.704) segments, while there was significant overestimation for heavily calcified segments (P = 0.001). Great qualitative and quantitative diagnostic performances of 320-slice CT were observed in non-calcified coronary segments. However, qualitative

  18. Virtual reality boosts performance at AREVA Projects

    International Nuclear Information System (INIS)

    Bernasconi, F.

    2017-01-01

    AREVA Projects is one of the 6 business units of New AREVA and it is dedicated to engineering works in a vast fan of activities from mining to waste management via uranium chemistry and nuclear fuel recycling. AREVA projects has opted for innovation to improve performance. Since 2012 virtual reality has been used through the creation of a room equipped with a high-definition screen and stereoscopic goggles. At the beginning virtual reality was used to test and validate procedures for handling equipment thanks to a dynamical digital simulation of this equipment. Now virtual reality is massively used to validate the design phase of projects without having to fabricate a physical mock-up which saves time. The next step in the use of virtual reality is the implementation of a new version of devices like helmets, gloves... that will allow a better interaction with the virtual world. The continuously increasing of computer power is always pushing back the limits of what is possible in virtual reality. (A.C.)

  19. PERFORMANCE ANALYSIS OF PROJECTS IMPLEMENTATION IN HEIS

    Directory of Open Access Journals (Sweden)

    Sergiu-Vlad PETCU

    2015-04-01

    Full Text Available According to the European Commission, Romania is still facing significant mismatch between the skills of graduates of tertiary education and the market needs. This paper is highly relevant for the future implementation of HEIs, since they have a strong economic role and they can significantly influence long-term national social and economical development. Romania did not manage to materialize community funds allocated for the 2007-2013 programming period to its full potential. Accordingly, the proposed thesis intends to analyse how Romanian HEIs were able to manage community resources attracted by grants and how the implemented projects achieved their set objectives. According to the data collected so far, the results will show that the performance of the projects is directly dependent on the proportion of fully dedicated staff in organizational design of the project. The originality of the undertaken study is that it starts from a realistic approach, according to which the rules of the game should be adapted, depending on the players (in our case – HEIs.

  20. Organizational Performance: Integration of the Value, Rarity, Imitability and Organization Framework in Project Management

    Directory of Open Access Journals (Sweden)

    Ronielton Rezende Oliveira

    2017-08-01

    Full Text Available Organizational performance is often associated with competitive advantage. In strategy studie saimed at expanding communication on a global vision of organizations and their initiatives, strategic project management stands out, whichis related to the mechanisms and set of management decisions that determine long term organizational performance. This study verify how the Resource-based view adds value to organizational initiatives seeking to achieve organizational performance through projects. The study considers strategic management practiced by the project managers o asto present a conceptual framework with four propositions that demonstrate the integration of the Value, Rarity, Imitability and Organization framework with project management and its relations to organizational performance.

  1. The Autism Diagnostic Observation Schedule--Toddler Module: A New Module of a Standardized Diagnostic Measure for Autism Spectrum Disorders

    Science.gov (United States)

    Luyster, Rhiannon; Gotham, Katherine; Guthrie, Whitney; Coffing, Mia; Petrak, Rachel; Pierce, Karen; Bishop, Somer; Esler, Amy; Hus, Vanessa; Oti, Rosalind; Richler, Jennifer; Risi, Susan; Lord, Catherine

    2009-01-01

    The Autism Diagnostic Observation Schedule (ADOS; Lord et al., J Autism Dev Disord, 30(3):205-223, 2000) is widely accepted as a "gold standard" diagnostic instrument, but it is of restricted utility with very young children. The purpose of the current project was to modify the ADOS for use in children under 30 months of age. A modified ADOS, the…

  2. Diagnostic Performance of Three Phase Bone Scan for Complex Regional Pain Syndrome Type 1 with Optimally Modified Image Criteria

    Energy Technology Data Exchange (ETDEWEB)

    Kwon, Hyun Woo; Paeng, Jin Chul; Nahm, Francins Sahngun; Kim, Seog Gyun; Zehra, Tanzeel; Oh, So Won; Lee, Hyo Sang; Kang, Keon Wook; Chung, June Key; Lee, Myung Chul; Lee, Dong Soo [Seoul National Univ. College of Medicine, Seoul (Korea, Republic of)

    2011-12-15

    Although the three phase bone scan (TBPS) is one of the widely used imaging studies for diagnosing complex regional pain syndrome type 1 (CRPS 1), there is some controversy regarding the TPBS image criteria for CRPS 1. In this study, we modified the image criteria using image pattern and quantitative analysis in the patients diagnosed using the most recent consensus clinical diagnostic criteria. The study included 140 patients with suspected CRPS 1 (CRPS 1, n=79; non CRPS, n=61; mean age 39{+-}15 years) who underwent TPBS. The clinical diagnostic criteria for CRPS 1 revised by the Budapest consensus group were used for confirmative diagnosis. Patients were classified according to flow/pool and delayed uptake (DU) image patterns, and the time interval between the initiating event and TPBS (TI{sup eventscan)}. Quantitative analysis for lesion to contralateral ratio (LCR) was performed. Modified TPBS image criteria were created and evaluated for optimal diagnostic performance. Both increased and decreased periarticular DU were significant image findings for CRPS 1 (CRPS 1 positive rate=73% in the increased DU group, 75% in the decreased DU group). The TI{sup eventscand}id not differ significantly between the different image pattern groups. Quantitative analysis revealed an LCR of 1.43 was the optimal cutoff value for CRPS 1 and diagnostic performance was significantly improved in the increased DU group (area under the curve=0.732). Given the modified image criteria, the sensitivity and specificity of TPBS for diagnosing CRPS 1 were 80% and 72%, respectively. Optimally modified TPBS image criteria for CRPS 1 were suggested using image pattern and quantitative analysis. With the criteria, TPBS is an effective imaging study for CRPS 1 even with the most recent consensus clinical diagnostic criteria.

  3. Diagnostic Performance of Three Phase Bone Scan for Complex Regional Pain Syndrome Type 1 with Optimally Modified Image Criteria

    International Nuclear Information System (INIS)

    Kwon, Hyun Woo; Paeng, Jin Chul; Nahm, Francins Sahngun; Kim, Seog Gyun; Zehra, Tanzeel; Oh, So Won; Lee, Hyo Sang; Kang, Keon Wook; Chung, June Key; Lee, Myung Chul; Lee, Dong Soo

    2011-01-01

    Although the three phase bone scan (TBPS) is one of the widely used imaging studies for diagnosing complex regional pain syndrome type 1 (CRPS 1), there is some controversy regarding the TPBS image criteria for CRPS 1. In this study, we modified the image criteria using image pattern and quantitative analysis in the patients diagnosed using the most recent consensus clinical diagnostic criteria. The study included 140 patients with suspected CRPS 1 (CRPS 1, n=79; non CRPS, n=61; mean age 39±15 years) who underwent TPBS. The clinical diagnostic criteria for CRPS 1 revised by the Budapest consensus group were used for confirmative diagnosis. Patients were classified according to flow/pool and delayed uptake (DU) image patterns, and the time interval between the initiating event and TPBS (TI eventscan) . Quantitative analysis for lesion to contralateral ratio (LCR) was performed. Modified TPBS image criteria were created and evaluated for optimal diagnostic performance. Both increased and decreased periarticular DU were significant image findings for CRPS 1 (CRPS 1 positive rate=73% in the increased DU group, 75% in the decreased DU group). The TI eventscand id not differ significantly between the different image pattern groups. Quantitative analysis revealed an LCR of 1.43 was the optimal cutoff value for CRPS 1 and diagnostic performance was significantly improved in the increased DU group (area under the curve=0.732). Given the modified image criteria, the sensitivity and specificity of TPBS for diagnosing CRPS 1 were 80% and 72%, respectively. Optimally modified TPBS image criteria for CRPS 1 were suggested using image pattern and quantitative analysis. With the criteria, TPBS is an effective imaging study for CRPS 1 even with the most recent consensus clinical diagnostic criteria.

  4. Review of diagnostics for next generation linear accelerators

    CERN Document Server

    Ross, M

    2001-01-01

    New electron linac designs incorporate substantial advances in critical beam parameters such as beam loading and bunch length and will require new levels of performance in stability and phase space control. In the coming decade, e- (and e+) linacs will be built for a high power linear collider (TESLA, CLIC, JLC/NLC), for fourth generation X-ray sources (TESLA FEL, LCLS, Spring 8 FEL) and for basic accelerator research and development (Orion). Each project assumes significant instrumentation performance advances across a wide front. This review will focus on basic diagnostics for beam position and phase space monitoring. Research and development efforts aimed at high precision multi-bunch beam position monitors, transverse and longitudinal profile monitors and timing systems will be described.

  5. Iterative reconstruction technique with reduced volume CT dose index: diagnostic accuracy in pediatric acute appendicitis

    International Nuclear Information System (INIS)

    Didier, Ryne A.; Vajtai, Petra L.; Hopkins, Katharine L.

    2015-01-01

    Iterative reconstruction technique has been proposed as a means of reducing patient radiation dose in pediatric CT. Yet, the effect of such reductions on diagnostic accuracy has not been thoroughly evaluated. This study compares accuracy of diagnosing pediatric acute appendicitis using contrast-enhanced abdominopelvic CT scans performed with traditional pediatric weight-based protocols and filtered back projection reconstruction vs. a filtered back projection/iterative reconstruction technique blend with reduced volume CT dose index (CTDI vol ). Results of pediatric contrast-enhanced abdominopelvic CT scans done for pain and/or suspected appendicitis were reviewed in two groups: A, 192 scans performed with the hospital's established weight-based CT protocols and filtered back projection reconstruction; B, 194 scans performed with iterative reconstruction technique and reduced CTDI vol . Reduced CTDI vol was achieved primarily by reductions in effective tube current-time product (mAs eff ) and tube peak kilovoltage (kVp). CT interpretation was correlated with clinical follow-up and/or surgical pathology. CTDI vol , size-specific dose estimates (SSDE) and performance characteristics of the two CT techniques were then compared. Between groups A and B, mean CTDI vol was reduced by 45%, and mean SSDE was reduced by 46%. Sensitivity, specificity and diagnostic accuracy were 96%, 97% and 96% in group A vs. 100%, 99% and 99% in group B. Accuracy in diagnosing pediatric acute appendicitis was maintained in contrast-enhanced abdominopelvic CT scans that incorporated iterative reconstruction technique, despite reductions in mean CTDI vol and SSDE by nearly half as compared to the hospital's traditional weight-based protocols. (orig.)

  6. T1 mapping cardiovascular magnetic resonance imaging to detect myocarditis—Impact of slice orientation on the diagnostic performance

    Energy Technology Data Exchange (ETDEWEB)

    Bohnen, Sebastian, E-mail: s.bohnen@uke.de [University Medical Center Hamburg-Eppendorf, University Heart Center, General and Interventional Cardiology, Hamburg (Germany); Radunski, Ulf K., E-mail: u.radunski@uke.de [University Medical Center Hamburg-Eppendorf, University Heart Center, General and Interventional Cardiology, Hamburg (Germany); Lund, Gunnar K., E-mail: glund@uke.de [University Medical Center Hamburg-Eppendorf, Department of Diagnostic and Interventional Radiology, Hamburg (Germany); Tahir, Enver, E-mail: e.tahir@uke.de [University Medical Center Hamburg-Eppendorf, Department of Diagnostic and Interventional Radiology, Hamburg (Germany); Avanesov, Maxim, E-mail: m.avanesov@uke.de [University Medical Center Hamburg-Eppendorf, Department of Diagnostic and Interventional Radiology, Hamburg (Germany); Stehning, Christian, E-mail: christian.stehning@philips.com [Philips Research, Hamburg (Germany); Schnackenburg, Bernhard, E-mail: bernhard.schnackenburg@philips.com [Philips Healthcare Germany, Hamburg (Germany); Adam, Gerhard, E-mail: g.adam@uke.de [University Medical Center Hamburg-Eppendorf, Department of Diagnostic and Interventional Radiology, Hamburg (Germany); Blankenberg, Stefan, E-mail: s.blankenberg@uke.de [University Medical Center Hamburg-Eppendorf, University Heart Center, General and Interventional Cardiology, Hamburg (Germany); Muellerleile, Kai, E-mail: kamuellerleile@uke.de [University Medical Center Hamburg-Eppendorf, University Heart Center, General and Interventional Cardiology, Hamburg (Germany)

    2017-01-15

    Background: T1 mapping is a promising diagnostic tool to improve the diagnostic accuracy of cardiovascular magnetic resonance (CMR) in patients with suspected myocarditis. However, there are currently no data on the potential influence of slice orientation on the diagnostic performance of CMR. Thus, we compared the diagnostic performance of global myocardial T1 and extracellular volume (ECV) values to differentiate patients with myocarditis from healthy individuals between different slice orientations. Methods: This study included 48 patients with clinically defined myocarditis and 13 healthy controls who underwent CMR at 1.5 T. A modified Look-Locker inversion-recovery (MOLLI) sequence was used for T1 mapping before and 15 min after administration of 0.075 mmol/kg Gadolinium-BOPTA. T1 mapping was performed on three short and on three long axes slices, respectively. Native T1, post-contrast T1 and extracellular volume (ECV) −BOPTA maps were calculated using a dedicated plug-in written for the OsiriX software and compared between the mean value of three short-axes slices (3SAX), the central short-axis (1SAX), the mean value of three long-axes slices (3LAX), the four-chamber view (4CH), the three-chamber view (3CH) and the two-chamber view (2CH). Results: There were significantly lower native T1 values on 3LAX (1081 ms (1037–1131 ms)) compared to 3SAX (1107 ms (1069–1143 ms), p = 0.0022) in patients with myocarditis, but not in controls (1026 ms (1009–1059 ms) vs. 1039 ms (1023–1055 ms), p = 0.2719). The areas under the curve (AUC) to discriminate between myocarditis and healthy controls by native myocardial T1 were 0.85 (p < 0.0001) on 3SAX, 0.85 (p < 0.0001) on 1SAX, 0.76 (p = 0.0002) on 3LAX, 0.70 (p = 0.0075) on 4CH, 0.72 (p = 0.0020) on 3CH and 0.75 (p = 0.0003) on 2CH. The AUCs for ECV-BOPTA were 0.83 (p < 0.0001) on 3 SAX, 0.82 (p < 0.0001) on 1SAX, 0.77 (p = 0.0005) on 3LAX, 0.71 (p = 0.0079) on 4CH, 0.69 (p = 0.0371) on 3CH and 0.75 (p = 0.0006) on

  7. T1 mapping cardiovascular magnetic resonance imaging to detect myocarditis—Impact of slice orientation on the diagnostic performance

    International Nuclear Information System (INIS)

    Bohnen, Sebastian; Radunski, Ulf K.; Lund, Gunnar K.; Tahir, Enver; Avanesov, Maxim; Stehning, Christian; Schnackenburg, Bernhard; Adam, Gerhard; Blankenberg, Stefan; Muellerleile, Kai

    2017-01-01

    Background: T1 mapping is a promising diagnostic tool to improve the diagnostic accuracy of cardiovascular magnetic resonance (CMR) in patients with suspected myocarditis. However, there are currently no data on the potential influence of slice orientation on the diagnostic performance of CMR. Thus, we compared the diagnostic performance of global myocardial T1 and extracellular volume (ECV) values to differentiate patients with myocarditis from healthy individuals between different slice orientations. Methods: This study included 48 patients with clinically defined myocarditis and 13 healthy controls who underwent CMR at 1.5 T. A modified Look-Locker inversion-recovery (MOLLI) sequence was used for T1 mapping before and 15 min after administration of 0.075 mmol/kg Gadolinium-BOPTA. T1 mapping was performed on three short and on three long axes slices, respectively. Native T1, post-contrast T1 and extracellular volume (ECV) −BOPTA maps were calculated using a dedicated plug-in written for the OsiriX software and compared between the mean value of three short-axes slices (3SAX), the central short-axis (1SAX), the mean value of three long-axes slices (3LAX), the four-chamber view (4CH), the three-chamber view (3CH) and the two-chamber view (2CH). Results: There were significantly lower native T1 values on 3LAX (1081 ms (1037–1131 ms)) compared to 3SAX (1107 ms (1069–1143 ms), p = 0.0022) in patients with myocarditis, but not in controls (1026 ms (1009–1059 ms) vs. 1039 ms (1023–1055 ms), p = 0.2719). The areas under the curve (AUC) to discriminate between myocarditis and healthy controls by native myocardial T1 were 0.85 (p < 0.0001) on 3SAX, 0.85 (p < 0.0001) on 1SAX, 0.76 (p = 0.0002) on 3LAX, 0.70 (p = 0.0075) on 4CH, 0.72 (p = 0.0020) on 3CH and 0.75 (p = 0.0003) on 2CH. The AUCs for ECV-BOPTA were 0.83 (p < 0.0001) on 3 SAX, 0.82 (p < 0.0001) on 1SAX, 0.77 (p = 0.0005) on 3LAX, 0.71 (p = 0.0079) on 4CH, 0.69 (p = 0.0371) on 3CH and 0.75 (p = 0.0006) on

  8. Diagnostics for Evaluating Performance of NSTX Liquid Lihium Divertor

    Science.gov (United States)

    Kaita, R.; Kugel, H.; Kallman, J.; Leblanc, B.; Paul, S.; Roquemore, A. L.; Skinner, C.; Soukhanovskii, V.; Maingi, R.; Ahn, J.-W.; Wilgen, J.; Allain, J.-P.; Taylor, C.

    2009-11-01

    A Liquid Lithium Divertor (LLD) is being installed on NSTX to investigate particle control and power handling with liquid lithium as plasma-facing component (PFC). The LLD is expected to provide a low-recycling plasma-facing component (PFC). To study the effects of such a PFC on plasma performance, a variety of edge measurements are required. Since its surface is highly reflective at visible wavelengths, a Lyman-alpha detector array will be used to monitor the recycling. To understand changes in edge transport, electron temperature and density measurements will be made with Langmuir probes mounted in PFC's near the LLD, and the edge sightlines of a multipoint Thomson scattering system. A frequency-scanning reflectometer will also provide scrapeoff layer electron density profiles. The LLD response to heat loads will be examined with infrared cameras and thermocouples. Diagnostics are also needed to measure the erosion and codeposition of lithium. They include quartz deposition monitors and a retractable probe for exposing samples to the plasma.

  9. Additive manufacture (3d printing) of plasma diagnostic components and assemblies for fusion experiments

    Science.gov (United States)

    Sieck, Paul; Woodruff, Simon; Stuber, James; Romero-Talamas, Carlos; Rivera, William; You, Setthivoine; Card, Alexander

    2015-11-01

    Additive manufacturing (or 3D printing) is now becoming sufficiently accurate with a large range of materials for use in printing sensors needed universally in fusion energy research. Decreasing production cost and significantly lowering design time of energy subsystems would realize significant cost reduction for standard diagnostics commonly obtained through research grants. There is now a well-established set of plasma diagnostics, but these expensive since they are often highly complex and require customization, sometimes pace the project. Additive manufacturing (3D printing) is developing rapidly, including open source designs. Basic components can be printed for (in some cases) less than 1/100th costs of conventional manufacturing. We have examined the impact that AM can have on plasma diagnostic cost by taking 15 separate diagnostics through an engineering design using Conventional Manufacturing (CM) techniques to determine costs of components and labor costs associated with getting the diagnostic to work as intended. With that information in hand, we set about optimizing the design to exploit the benefits of AM. Work performed under DOE Contract DE-SC0011858.

  10. Alzheimer's Disease Diagnostic Performance of a Multi-Atlas Hippocampal Segmentation Method using the Harmonized Hippocampal Protocol

    DEFF Research Database (Denmark)

    Anker, Cecilie Benedicte; Sørensen, Lauge; Pai, Akshay

    PURPOSE Hippocampal volumetry is the most widely used structural MRI biomarker of Alzheimer’s disease (AD), and state-of-the-art, automatic hippocampal segmentation can be obtained using longitudinal FreeSurfer. In this study, we compare the diagnostic AD performance of a single time point, multi...

  11. The diagnostic performance of magnetic resonance spectroscopy in differentiating high-from low-grade gliomas: A systematic review and meta-analysis

    International Nuclear Information System (INIS)

    Wang, Qun; Zhang, JiaShu; Wu, Chen; Li, FangYe; Chen, XiaoLei; Xu, BaiNan; Zhang, Hui; Zhu, WeiJie

    2016-01-01

    Magnetic resonance spectroscopy (MRS) is a powerful tool for preoperative grading of gliomas. We performed a meta-analysis to evaluate the diagnostic performance of MRS in differentiating high-grade gliomas (HGGs) from low-grade gliomas (LGGs). PubMed and Embase databases were systematically searched for relevant studies of glioma grading assessed by MRS through 27 March 2015. Based on the data from eligible studies, pooled sensitivity, specificity, diagnostic odds ratio and areas under summary receiver operating characteristic curve (SROC) of different metabolite ratios were obtained. Thirty articles comprising a total sample size of 1228 patients were included in our meta-analysis. Quantitative synthesis of studies showed that the pooled sensitivity/specificity of Cho/Cr, Cho/NAA and NAA/Cr ratios was 0.75/0.60, 0.80/0.76 and 0.71/0.70, respectively. The area under the curve (AUC) of the SROC was 0.83, 0.87 and 0.78, respectively. MRS demonstrated moderate diagnostic performance in distinguishing HGGs from LGGs using tumoural metabolite ratios including Cho/Cr, Cho/NAA and NAA/Cr. Although there was no significant difference in AUC between Cho/Cr and Cho/NAA groups, Cho/NAA ratio showed higher sensitivity and specificity than Cho/Cr ratio and NAA/Cr ratio. We suggest that MRS should combine other advanced imaging techniques to improve diagnostic accuracy in differentiating HGGs from LGGs. (orig.)

  12. Diagnostics systems for the TBR-E tokamak

    International Nuclear Information System (INIS)

    Ueda, M.; Ferreira, J.L.; Aso, Y.; Ferreira, J.G.

    1992-08-01

    A general view of the several diagnostics systems proposed for the TBR-E tokamak is given. This project is a joint undertaking of INPE, USP and UNICAMP plasma laboratories. The requirements for the measurements of the plasma produced parameters are described. Special attention is given for diagnostics used to investigate new physical issues on a low aspect ratio tokamak such as TBR-E. (author)

  13. The Interobserver Variability and Diagnostic Performance of 3-Dimensional Breast Ultrasound

    International Nuclear Information System (INIS)

    Lyou, Chae Yeon; Kim, Sun Mi; Jang, Mi Jung; Kim, Sung Won; Kang, Eun Young; Park, So Yeon; Moon, Woo Kyung

    2011-01-01

    We wanted to evaluate the interobserver variability and diagnostic performance of 3-dimensional (3D) breast ultrasound (US) as compared with that of 2- dimensional (2D) US. We included 150 patients who received US-guided core biopsy and 3D US between June 2009 and April 2010. Three breast imaging radiologists analyzed the 2D and 3D US images using the Breast Imaging Reporting and Data System (BI-RADS) lexicon. The intra-observer agreement and inter-observer agreement were calculated. The sensitivity and specificity of 2D and 3D US were evaluated. The intra-observer agreement between 2D and 3D US was mostly slight or fair agreement. However, in terms of the final category, there was substantial agreement for all three radiologists. The inter-observer agreement of 3D US was similar to that of 2D US (moderate agreement for shape, orientation, circumscribed margin and boundary: fair agreement for indistinct margin, angular margin, microlobulated margin, echo pattern and final category). The sensitivity of 3D US for breast cancer was higher than that of 2D US for two radiologists (2D vs. 3D for reader 2: 55.8% vs. 61.5%, 2D vs. 3D for reader 3: 59.6% vs. 63.5%), and the specificity of 3D US was lower than that of 2D US for all the readers (2D vs. 3D for reader 1: 90.8% vs. 86.7%, 2D vs. 3D for reader 2: 90.8% vs. 87.8%, 2D vs. 3D for reader 3: 94.9% vs. 90.8%), but the difference was not significant (p ≥ 0.05). The interobserver variability and diagnostic performance of 3D breast US were similar to those of 2D US

  14. Performance Evaluation of Public-Private Partnership Projects from the Perspective of Efficiency, Economic, Effectiveness, and Equity: A Study of Residential Renovation Projects in China

    Directory of Open Access Journals (Sweden)

    Xuhui Cong

    2018-06-01

    Full Text Available The performance evaluation index system was established on the basis of 4E (Efficiency, Economic, Effectiveness, Equity theory to improve performance evaluation of Public-Private Partnership Projects for Residential Renovation (4P2R. Moreover, the index weighting model was demonstrated based on Ordered Weighted Averaging (OWA. Finally, the cloud model was used for performance evaluation, through the cloud uncertainty reasoning to determine the quantitative performance evaluation index value, the positive reverse cloud to calculate the qualitative performance evaluation index value, and the normal cloud to measure the project performance. The proof-of-concept application shows that the performance evaluation index system and evaluation model can better identify the deficiencies in the project, and provide targeted improvement measures for similar projects in the future.

  15. Diagnostic Performance of Magnifying Endoscopy for Helicobacter pylori Infection: A Meta-Analysis.

    Directory of Open Access Journals (Sweden)

    Qingqing Qi

    Full Text Available Diagnosis of Helicobacter pylori (H. pylori infection using magnifying endoscopy offers advantages over conventional invasive and noninvasive tests.This meta-analysis aimed to assess the diagnostic performance of magnifying endoscopy in the prediction of H. pylori infection.A literature search of the PubMed, Medline, EMBASE, Science Direct and the Cochrane Library databases was performed. A random-effects model was used to calculate the diagnostic efficiency of magnifying endoscopy for H. pylori infection. A summary receiver operator characteristic curve was plotted, and the area under the curve (AUC was calculated.A total of 18 studies involving 1897 patients were included. The pooled sensitivity and specificity of magnifying endoscopy to predict H. pylori infection were 0.89 [95% confidence interval (CI 0.87-0.91] and 0.82 (95%CI 0.79-0.85, respectively, with an AUC of 0.9461. When targeting the gastric antrum, the pooled sensitivity and specificity were 0.82 (95%CI 0.78-0.86 and 0.72 (95%CI 0.66-0.78, respectively. When targeting the gastric corpus, the pooled sensitivity and specificity were 0.92 (95%CI 0.90-0.94 and 0.86 (95%CI 0.82-0.88, respectively. The pooled sensitivity and specificity using magnifying white light endoscopy were 0.90 (95%CI 0.87-0.91 and 0.81 (95%CI 0.77-0.84, respectively. The pooled sensitivity and specificity using magnifying chromoendoscopy were 0.87 (95%CI 0.83-0.91 and 0.85 (95%CI 0.80-0.88, respectively. The "pit plus vascular pattern" classification in the gastric corpus observed by magnifying endoscopy was able to accurately predict the status of H. pylori infection, as indicated by a pooled sensitivity and specificity of 0.96 (95%CI 0.94-0.97 and 0.91 (95%CI 0.87-0.93, respectively, with an AUC of 0.9872.Magnifying endoscopy was able to accurately predict the status of H. pylori infection, either in magnifying white light endoscopy or magnifying chromoendoscopy mode. The "pit plus vascular pattern

  16. Evaluating Levels of Project Planning and their Effects on Performance in the Nigerian Construction Industry

    Directory of Open Access Journals (Sweden)

    Godwin Idoro

    2012-11-01

    Full Text Available This study compares the level of project planning on public andprivate sectors projects and its impact on performance. Thepurpose is to create awareness of the level and effectivenessof the planning done by public and private clients in the deliveryof construction projects. A questionnaire survey administeredto a sample of 130 client representatives selected by stratifi edrandom sampling from the population of public and private clientsin the Nigerian construction industry is used and analysed usingdescriptive statistics, the t-test and Spearman correlation test. Theresults show that the level of preconstruction planning on privatesector projects is higher than that of public sector projects whilethe level of contract planning done by the latter is higher thanthat of the former. Furthermore, the performance of private sectorprojects is higher than that of public sector projects in many of theparameters used. However, the level of preparation of life-cyclecharts that concern project delivery time in both public and privatesectors projects is low and the level of project planning in the twocategories of projects has a limited impact on project performance.The understanding of how public and private sectors projectsperform in planning and its impact are expected to assist publicand private clients to know the challenges ahead of them in theireffort to improve the planning and performance of their projects.

  17. Evaluation of diagnostic performance of whole-body simultaneous PET/MRI in pediatric lymphoma

    International Nuclear Information System (INIS)

    Ponisio, Maria Rosana; Laforest, Richard; Khanna, Geetika; McConathy, Jonathan

    2016-01-01

    Whole-body 18 F-fluorodeoxyglucose (FDG) positron emission tomography/computed tomography (PET/CT) is the standard of care for lymphoma. Simultaneous PET/MRI (magnetic resonance imaging) is a promising new modality that combines the metabolic information of PET with superior soft-tissue resolution and functional imaging capabilities of MRI while decreasing radiation dose. There is limited information on the clinical performance of PET/MRI in the pediatric setting. This study evaluated the feasibility, dosimetry, and qualitative and quantitative diagnostic performance of simultaneous whole-body FDG-PET/MRI in children with lymphoma compared to PET/CT. Children with lymphoma undergoing standard of care FDG-PET/CT were prospectively recruited for PET/MRI performed immediately after the PET/CT. Images were evaluated for quality, lesion detection and anatomical localization of FDG uptake. Maximum and mean standardized uptake values (SUV max/mean ) of normal organs and SUV max of the most FDG-avid lesions were measured for PET/MRI and PET/CT. Estimation of radiation exposure was calculated using specific age-related factors. Nine PET/MRI scans were performed in eight patients (mean age: 15.3 years). The mean time interval between PET/CT and PET/MRI was 51 ± 10 min. Both the PET/CT and PET/MRI exams had good image quality and alignment with complete (9/9) concordance in response assessment. The SUVs from PET/MRI and PET/CT were highly correlated for normal organs (SUV mean r 2 : 0.88, P<0.0001) and very highly for FDG-avid lesions (SUV max r 2 : 0.94, P=0.0002). PET/MRI demonstrated an average percent radiation exposure reduction of 39% ± 13% compared with PET/CT. Simultaneous whole-body PET/MRI is clinically feasible in pediatric lymphoma. PET/MRI performance is comparable to PET/CT for lesion detection and SUV measurements. Replacement of PET/CT with PET/MRI can significantly decrease radiation dose from diagnostic imaging in children. (orig.)

  18. Diagnostic performance of dual-staining cytology for cervical cancer screening: A systematic literature review.

    Science.gov (United States)

    Tjalma, Wiebren A A

    2017-03-01

    Cervical cancer screening saves lives. Secondary prevention in cervical cancer screening relies on the results of primary cytology and/or HPV testing. However, primary screening with cytology has a low sensitivity, and HPV screening has a low specificity. This means that either cancers are missed, or women are over-treated. To improve performance outcomes, the concept of dual-stain cytology (CINtec ® PLUS Cytology test) has been introduced. In this approach, additional staining with p16/Ki-67 is performed in cases where cytology results are abnormal (LSIL or ASCUS) and/or HPV-positive. Another way to describe this approach might be "diagnostic" cytology. In order to assess the value of this "diagnostic cytology", a systematic literature review was conducted of dual-stain cytology performance across multiple studies until May 2016. In a Belgian screening population (women age 25-65 years), dual-stain cytology was significantly more sensitive (66%) and slightly less specific (-1.0%) than cytology. In the population referred to colposcopy or with abnormal cytology (ASCUS, LSIL), dual-staining showed a significantly higher increase in specificity, and a slightly lower sensitivity than HPV testing. Specificity gains resulted in fewer false positives and an increase in the number of correct referrals to colposcopy. Dual-staining with p16/Ki-67 cytology is an attractive biomarker approach for triage in cervical cancer screening. Copyright © 2017 Elsevier B.V. All rights reserved.

  19. TWENTY-ONE-YEAR EXTENSION PROJECT PERFORMANCE "LET'S BREASTFEEDING, MOMMY?"

    Directory of Open Access Journals (Sweden)

    Marizete Argolo Teixeira

    2017-05-01

    Full Text Available Research aiming to describe the actions that were developed by the Extension Project "Let's breastfeed, Mom?" During the 21 years of its performance in Jequié / Bahia and identify the difficulties, facilities and progress of the project. This is a descriptive, quantitative-qualitative study. The data were collected in the archived project documents, analyzed through descriptive statistics and content analysis. The results showed that 8,923 registered postpartum women with educational activities and 1,313 domiciliary visits were carried out, as the main actions carried out by the project. The difficulties were: lack of consumer / permanent materials and human resources; As facilities: responsibility and commitment of the members of the project, as well as the support of the transportation service of the institution. The advances were the elaboration of the research project, with insertion of research fellows, creation of the webpage and the logo. It is necessary to reflect on the difficulties and propose measures to remedy them and thus continue to contribute to the promotion, protection and support of breastfeeding in the Municipality, contributing to the reduction of infant morbidity and mortality

  20. Diagnostic performance of qualitative shear-wave elastography according to different color map opacities for breast masses

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Hana; Youk, Ji Hyun, E-mail: jhyouk@yuhs.ac; Gweon, Hye Mi; Kim, Jeong-Ah; Son, Eun Ju

    2013-08-15

    Purpose: To compare the diagnostic performance of qualitative shear-wave elastography (SWE) according to three different color map opacities for breast masses Materials and methods: 101 patients aged 21–77 years with 113 breast masses underwent B-mode US and SWE under three different color map opacities (50%, 19% and 100%) before biopsy or surgery. Following SWE features were reviewed: visual pattern classification (pattern 1–4), color homogeneity (E{sub homo}) and six-point color score of maximum elasticity (E{sub col}). Combined with B-mode US and SWE, the likelihood of malignancy (LOM) was also scored. The area under the curve (AUC) was obtained by ROC curve analysis to assess the diagnostic performance under each color opacity. Results: A visual color pattern, E{sub homo}, E{sub col} and LOM scoring were significantly different between benign and malignant lesions under all color opacities (P < 0.001). For 50% opacity, AUCs of visual color pattern, E{sub col}, E{sub homo} and LOM scoring were 0.902, 0.951, 0.835 and 0.975. But, for each SWE feature, there was no significant difference in the AUC among three different color opacities. For all color opacities, visual color pattern and E{sub col} showed significantly higher AUC than E{sub homo}. In addition, a combined set of B-mode US and SWE showed significantly higher AUC than SWE alone for color patterns, E{sub homo}, but no significant difference was found in E{sub col}. Conclusion: Qualitative SWE was useful to differentiate benign from malignant breast lesion under all color opacities. The difference in color map opacity did not significantly influence diagnostic performance of SWE.

  1. Diagnostic performance of qualitative shear-wave elastography according to different color map opacities for breast masses

    International Nuclear Information System (INIS)

    Kim, Hana; Youk, Ji Hyun; Gweon, Hye Mi; Kim, Jeong-Ah; Son, Eun Ju

    2013-01-01

    Purpose: To compare the diagnostic performance of qualitative shear-wave elastography (SWE) according to three different color map opacities for breast masses Materials and methods: 101 patients aged 21–77 years with 113 breast masses underwent B-mode US and SWE under three different color map opacities (50%, 19% and 100%) before biopsy or surgery. Following SWE features were reviewed: visual pattern classification (pattern 1–4), color homogeneity (E homo ) and six-point color score of maximum elasticity (E col ). Combined with B-mode US and SWE, the likelihood of malignancy (LOM) was also scored. The area under the curve (AUC) was obtained by ROC curve analysis to assess the diagnostic performance under each color opacity. Results: A visual color pattern, E homo , E col and LOM scoring were significantly different between benign and malignant lesions under all color opacities (P < 0.001). For 50% opacity, AUCs of visual color pattern, E col , E homo and LOM scoring were 0.902, 0.951, 0.835 and 0.975. But, for each SWE feature, there was no significant difference in the AUC among three different color opacities. For all color opacities, visual color pattern and E col showed significantly higher AUC than E homo . In addition, a combined set of B-mode US and SWE showed significantly higher AUC than SWE alone for color patterns, E homo , but no significant difference was found in E col . Conclusion: Qualitative SWE was useful to differentiate benign from malignant breast lesion under all color opacities. The difference in color map opacity did not significantly influence diagnostic performance of SWE

  2. TH-F-209-01: Pitfalls: Reliability and Performance of Diagnostic X-Ray Sources

    International Nuclear Information System (INIS)

    Behling, R.

    2016-01-01

    Purpose: Performance and reliability of medical X-ray tubes for imaging are crucial from an ethical, clinical and economic perspective. This lecture will deliver insight into the aspects to consider during the decision making process to invest in X-ray imaging equipment. Outdated metric still hampers realistic product comparison. It is time to change this and to comply with latest standards, which consider current technology. Failure modes and ways to avoid down-time of the equipment shall be discussed. In view of the increasing number of interventional procedures and the hazards associated with ionizing radiation, toxic contrast agents, and the combination thereof, the aspect of system reliability is of paramount importance. Methods: A comprehensive picture of trends for different modalities (CT, angiography, general radiology) has been drawn and led to the development of novel X-ray tube technology. Results: Recent X-ray tubes feature enhanced reliability and unprecedented performance. Relevant metrics for product comparison still have to be implemented in practice. Conclusion: The speed of scientific and industrial development of new diagnostic and therapeutic X-ray sources remains tremendous. Still, users suffer from gaps between desire and reality in day-to-day diagnostic routine. X-ray sources are still limiting cutting-edge medical procedures. Side-effects of wear and tear, limitations of the clinical work flow, costs, the characteristics of the X-ray spectrum and others topics need to be further addressed. New applications and modalities, like detection-based color-resolved X-ray and phase-contrast / dark-field imaging will impact the course of new developments of X-ray sources. Learning Objectives: Understand the basic requirements on medical diagnostic X-ray sources per modality Learn to select the optimal equipment employing state-of-the-art metric Know causes of failures, depending on the way X-ray sources are operated Understand methods to remediate

  3. TH-F-209-00: Pitfalls: Reliability and Performance of Diagnostic X-Ray Sources

    International Nuclear Information System (INIS)

    2016-01-01

    Purpose: Performance and reliability of medical X-ray tubes for imaging are crucial from an ethical, clinical and economic perspective. This lecture will deliver insight into the aspects to consider during the decision making process to invest in X-ray imaging equipment. Outdated metric still hampers realistic product comparison. It is time to change this and to comply with latest standards, which consider current technology. Failure modes and ways to avoid down-time of the equipment shall be discussed. In view of the increasing number of interventional procedures and the hazards associated with ionizing radiation, toxic contrast agents, and the combination thereof, the aspect of system reliability is of paramount importance. Methods: A comprehensive picture of trends for different modalities (CT, angiography, general radiology) has been drawn and led to the development of novel X-ray tube technology. Results: Recent X-ray tubes feature enhanced reliability and unprecedented performance. Relevant metrics for product comparison still have to be implemented in practice. Conclusion: The speed of scientific and industrial development of new diagnostic and therapeutic X-ray sources remains tremendous. Still, users suffer from gaps between desire and reality in day-to-day diagnostic routine. X-ray sources are still limiting cutting-edge medical procedures. Side-effects of wear and tear, limitations of the clinical work flow, costs, the characteristics of the X-ray spectrum and others topics need to be further addressed. New applications and modalities, like detection-based color-resolved X-ray and phase-contrast / dark-field imaging will impact the course of new developments of X-ray sources. Learning Objectives: Understand the basic requirements on medical diagnostic X-ray sources per modality Learn to select the optimal equipment employing state-of-the-art metric Know causes of failures, depending on the way X-ray sources are operated Understand methods to remediate

  4. TH-F-209-01: Pitfalls: Reliability and Performance of Diagnostic X-Ray Sources

    Energy Technology Data Exchange (ETDEWEB)

    Behling, R. [Philips Medical Systems DMC GmbH (United States)

    2016-06-15

    Purpose: Performance and reliability of medical X-ray tubes for imaging are crucial from an ethical, clinical and economic perspective. This lecture will deliver insight into the aspects to consider during the decision making process to invest in X-ray imaging equipment. Outdated metric still hampers realistic product comparison. It is time to change this and to comply with latest standards, which consider current technology. Failure modes and ways to avoid down-time of the equipment shall be discussed. In view of the increasing number of interventional procedures and the hazards associated with ionizing radiation, toxic contrast agents, and the combination thereof, the aspect of system reliability is of paramount importance. Methods: A comprehensive picture of trends for different modalities (CT, angiography, general radiology) has been drawn and led to the development of novel X-ray tube technology. Results: Recent X-ray tubes feature enhanced reliability and unprecedented performance. Relevant metrics for product comparison still have to be implemented in practice. Conclusion: The speed of scientific and industrial development of new diagnostic and therapeutic X-ray sources remains tremendous. Still, users suffer from gaps between desire and reality in day-to-day diagnostic routine. X-ray sources are still limiting cutting-edge medical procedures. Side-effects of wear and tear, limitations of the clinical work flow, costs, the characteristics of the X-ray spectrum and others topics need to be further addressed. New applications and modalities, like detection-based color-resolved X-ray and phase-contrast / dark-field imaging will impact the course of new developments of X-ray sources. Learning Objectives: Understand the basic requirements on medical diagnostic X-ray sources per modality Learn to select the optimal equipment employing state-of-the-art metric Know causes of failures, depending on the way X-ray sources are operated Understand methods to remediate

  5. TH-F-209-00: Pitfalls: Reliability and Performance of Diagnostic X-Ray Sources

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2016-06-15

    Purpose: Performance and reliability of medical X-ray tubes for imaging are crucial from an ethical, clinical and economic perspective. This lecture will deliver insight into the aspects to consider during the decision making process to invest in X-ray imaging equipment. Outdated metric still hampers realistic product comparison. It is time to change this and to comply with latest standards, which consider current technology. Failure modes and ways to avoid down-time of the equipment shall be discussed. In view of the increasing number of interventional procedures and the hazards associated with ionizing radiation, toxic contrast agents, and the combination thereof, the aspect of system reliability is of paramount importance. Methods: A comprehensive picture of trends for different modalities (CT, angiography, general radiology) has been drawn and led to the development of novel X-ray tube technology. Results: Recent X-ray tubes feature enhanced reliability and unprecedented performance. Relevant metrics for product comparison still have to be implemented in practice. Conclusion: The speed of scientific and industrial development of new diagnostic and therapeutic X-ray sources remains tremendous. Still, users suffer from gaps between desire and reality in day-to-day diagnostic routine. X-ray sources are still limiting cutting-edge medical procedures. Side-effects of wear and tear, limitations of the clinical work flow, costs, the characteristics of the X-ray spectrum and others topics need to be further addressed. New applications and modalities, like detection-based color-resolved X-ray and phase-contrast / dark-field imaging will impact the course of new developments of X-ray sources. Learning Objectives: Understand the basic requirements on medical diagnostic X-ray sources per modality Learn to select the optimal equipment employing state-of-the-art metric Know causes of failures, depending on the way X-ray sources are operated Understand methods to remediate

  6. Comparative Evaluation of the Diagnostic Performance of the Prototype Cepheid GeneXpert Ebola Assay

    Science.gov (United States)

    Jansen van Vuren, Petrus; Grobbelaar, Antoinette; Storm, Nadia; Conteh, Ousman; Konneh, Kelfala; Kamara, Abdul; Sanne, Ian

    2015-01-01

    The Ebola virus disease (EVD) outbreak in West Africa has highlighted an urgent need for point-of-care (POC) assays for the diagnosis of this devastating disease in resource-limited African countries. The diagnostic performance characteristics of a prototype Cepheid GeneXpert Ebola POC used to detect Ebola virus (EBOV) in stored serum and plasma samples collected from suspected EVD cases in Sierra Leone in 2014 and 2015 was evaluated. The GeneXpert Ebola POC is a self-contained single-cartridge automated system that targets the glycoprotein (GP) and nucleoprotein (NP) genes of EBOV and yields results within 90 min. Results from 281 patient samples were compared to the results of a TaqMan real-time reverse transcription-PCR (RT-PCR) targeting the polymerase gene and performed on two real-time PCR machines. Agreement between the three platforms was 100% at cycle threshold (CT) values of ≤34.99, but discordant results were noted between CT values of 35 and 45.The diagnostic sensitivity of the three platforms was 100% in 91 patient samples that were confirmed to be infectious by virus isolation. All three molecular platforms detected viral EBOV RNA in additional samples that did not contain viable EBOV. The analytical sensitivity of the GeneXpert Ebola POC for the detection of NP was higher, and comparable to that of polymerase gene detection, than that for the detection of GP when using a titrated laboratory stock of EBOV. There was no detectable cross-reactivity with other hemorrhagic fever viruses or arboviruses. The GeneXpert Ebola POC offers an easy to operate and sensitive diagnostic tool that can be used for the rapid screening of suspected EVD cases in treatment or in holding centers during EVD outbreaks. PMID:26637383

  7. The proposed Diagnostic Instrumentation and Analysis Laboratory, Mississippi State University

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1994-11-01

    The Department of Energy (DOE) proposes to authorize Mississippi State University (MSU) to proceed with the detailed design, construction and equipping of the proposed Diagnostic Instrumentation and Analysis Laboratory (DIAL). DOE grant funds are available to the University for the limited purpose of performing preliminary studies, including analysis necessary to conduct this environmental assessment. The proposed facility would be located in the Mississippi Research and Technology Park, adjacent to the Mississippi Agriculture and Forestry Experiment Station campus in Starkville, Mississippi. Total project cost is estimated at $7,953,600. This proposed laboratory would be designed to conduct research into combustion devices related to waste management and environmental restoration that is of importance to industry and government. The proposed facility`s role would be to develop diagnostic instrumentation capabilities in the area of combustion and related processes.

  8. Regional Diagnostic Reference Levels and Collective Effective Doses from Computed Tomography (CT) Scanners in India

    International Nuclear Information System (INIS)

    Livingstone, R.S.; Dinakaran, P.M.

    2011-01-01

    Diagnostic examinations performed using computed tomography (CT) are on the increase, and the use of this modality needs to be monitored periodically. The aim of this study was to formulate regional diagnostic reference levels (DRLs) and assess collective effective doses from CT scanners in Tamil Nadu, India. In-site CT dose measurements were performed for 127 CT scanners in Tamil Nadu as a part of the Atomic Energy Regulatory Board (AERB) funded project for a period of two years. Regional DRLs were formulated at third quartile level for three CT protocols such as thorax, abdomen and pelvis and were found to be 557 mGy.cm, 521 mGy.cm and 294 mGy.cm, respectively. The collective effective dose in Tamil Nadu was found to be 14.93 man Sv per day. (author)

  9. The diagnostic value of the 'skyline' view for radiographic examination of the equine navicular bone

    International Nuclear Information System (INIS)

    Zweers, A.D.; Dik, K.J.

    1988-01-01

    The radiographic diagnostic value of Rose's palmaroproximal-dorsodistal ('skyline') projection and Oxspring's dorsopalmar projection of the equine navicular bone were compared, by examining radiographs of 102 navicular bones originating from 66 randomly selected horses with clinical evidence of lameness located in the navicular area. In 27 navicular bones essential information was obtained from the skyline view, 15 independently of Oxspring's projection and 12 in addition to this view. For 11 navicular studies the D.P. projection was the most important diagnostic view. In the other 64 navicular bones information obtained from both views was of equal diagnostic value. Based on these results it is suggested that the skyline projection be utilized as an additional view, especially if there is a significant discrepancy between the clinical and radiographic findings based on lateromedial and Oxspring projections, and if ill-defined lesions of unknown significance are visible on the Oxspring projection [nl

  10. The performance indicators of model projects. A special evaluation

    International Nuclear Information System (INIS)

    1995-11-01

    As a result of the acknowledgment of the key role of the Model Project concept in the Agency's Technical Co-operation Programme, the present review of the objectives of the model projects which are now in operation, was undertaken, as recommended by the Board of Governors, to determine at an early stage: the extent to which the present objectives have been defined in a measurable way; whether objectively verifiable performance indicators and success criteria had been identified for each project; whether mechanisms to obtain feedback on the achievements had been foreseen. The overall budget for the 23 model projects, as approved from 1994 to 1998, amounts to $32,557,560, of which 45% is funded by Technical Co-operation Fund. This represents an average investment of about $8 million per year, that is over 15% of the annual TC budget. The conceptual importance of the Model Project initiative, as well as the significant funds allocated to them, led the Secretariat to plan the methods to be used to determine their socio-economic impact. 1 tab

  11. Measurement of the performance characteristics of diagnostic X-ray systems used in medicine

    International Nuclear Information System (INIS)

    1981-01-01

    A booklet has been produced by the Diagnostic Radiology Topic Group of the Hospital Physicists' Association, providing the basis for exhaustive performance tests on X-ray image intensifier television systems. After a general introduction to the equipment, the parameters which may need to be assessed are outlined in section 1. The measurement techniques and equipment necessary to undertake the measurements are presented in section 2. Specimen data sheets are also presented which the user may find useful to record the data acquired in the field. (U.K.)

  12. 41 CFR 102-74.135 - Who selects construction and alteration projects that are to be performed?

    Science.gov (United States)

    2010-07-01

    ... and alteration projects that are to be performed? 102-74.135 Section 102-74.135 Public Contracts and... construction and alteration projects that are to be performed? The Administrator of General Services selects construction and alteration projects to be performed. ...

  13. Diagnostic performance of fecal quantitative real-time polymerase chain reaction for detection of Lawsonia intracellularis–associated proliferative enteropathy in nursery pigs

    DEFF Research Database (Denmark)

    Pedersen, Ken Steen; Stege, Helle; Jensen, Tim Kåre

    2013-01-01

    Quantitative polymerase chain reaction (qPCR) tests for detection and quantification of Lawsonia intracellularis in feces from pigs have been developed. The objective of the current study was to evaluate the diagnostic performance of a fecal qPCR test for detection of nursery pigs with L. intrace......Quantitative polymerase chain reaction (qPCR) tests for detection and quantification of Lawsonia intracellularis in feces from pigs have been developed. The objective of the current study was to evaluate the diagnostic performance of a fecal qPCR test for detection of nursery pigs with L...

  14. Refining multi-model projections of temperature extremes by evaluation against land–atmosphere coupling diagnostics

    Directory of Open Access Journals (Sweden)

    S. Sippel

    2017-05-01

    , the differences between projected and present-day climate extremes are affected to a lesser extent by the applied constraint, i.e. projected changes are reduced locally by around 0.5 to 1 °C – but this remains a local effect in regions that are highly sensitive to land–atmosphere coupling. In summary, our approach offers a physically consistent, diagnostic-based avenue to evaluate multi-model ensembles and subsequently reduce model biases in simulated and projected extreme temperatures.

  15. The Clinical Utility and Diagnostic Performance of MRI for Identification of Early and Advanced Knee Osteoarthritis: A Systematic Review

    Science.gov (United States)

    Quatman, Carmen E.; Hettrich, Carolyn M.; Schmitt, Laura C.; Spindler, Kurt P.

    2013-01-01

    Background Current diagnostic strategies for detection of structural articular cartilage abnormalities, the earliest structural signs of osteoarthritis, often do not capture the condition until it is too far advanced for the most potential benefit of non-invasive interventions. Purpose Systematically review the literature relative to the following questions: (1) Is MRI a valid, sensitive, specific, accurate and reliable instrument to identify knee articular cartilage abnormalities compared to arthroscopy? (2) Is MRI a sensitive tool that can be utilized to identify early cartilage degeneration? Study Design Systematic Review Methods A systematic search was performed in November 2010 using PubMed MEDLINE (from 1966), CINAHL (from 1982), SPORTDiscus (from 1985), and SCOPUS (from 1996) databases. Results Fourteen level I and 13 level II studies were identified that met inclusion criteria and provided information related to diagnostic performance of MRI compared to arthroscopic evaluation. The diagnostic performance of MRI demonstrated a large range of sensitivities, specificities, and accuracies. The sensitivity for identifying articular cartilage abnormalities in the knee joint was reported between 26–96%. Specificity and accuracy was reported between 50–100% and 49–94%, respectively. The sensitivity, specificity, and accuracy for identifying early osteoarthritis were reported between 0–86%, 48–95%, and 5–94%, respectively. As a result of inconsistencies between imaging techniques and methodological shortcomings of many of the studies, a meta-analysis was not performed and it was difficult to fully synthesize the information to state firm conclusions about the diagnostic performance of MRI. Conclusions There is evidence in some MRI protocols that MRI is a relatively valid, sensitive, specific, accurate, and reliable clinical tool for identifying articular cartilage degeneration. Due to heterogeneity of MRI sequences it is not possible to make definitive

  16. SKI SITE-94. Deep Repository Performance Assessment Project. Summary

    International Nuclear Information System (INIS)

    1997-02-01

    The function of SITE-94 is to provide the Swedish Nuclear Power Inspectorate (SKI) with the capacity and supporting knowledge needed for reviewing the Swedish nuclear industry's R and D programs and for reviewing license applications, as stipulated in Swedish legislation. The report is structured as a Performance Assessment exercise needed for input to decisions regarding repository safety, but the SITE-94 is neither a safety assessment nor a model for future assessments to be undertaken by the prospective licensee. The specific project objectives of SITE-94 comprise site evaluation, performance assessment methodology, canister integrity and radionuclide release and transport calculations. The main report (SKI-R--96-36) gives a detailed description of the many inter-related studies undertaken as part of the research project, while the present report presents a condensed summary of the main report. 46 refs

  17. A project management framework for enhanced productivity performance using building information modelling

    Directory of Open Access Journals (Sweden)

    Longhui Liao

    2017-09-01

    Full Text Available Although the Singapore government has mandated submissions of building plans in building information modelling (BIM format since July 2013, this does not yet seem to lead to enhanced productivity performance. BIM collaboration between designers and downstream contractors appears to remain inadequate. While many studies have been conducted on using BIM for better project outcomes, studies that relate BIM with the identification of non-value adding activities in the project lifecycle and the reduction of the resulting wastes are at infancy stage. This paper aims to propose a project management framework for enhancing the productivity of building projects in Singapore, which forms Phase I of an ongoing research project. A two-pronged approach is presented. Firstly, non-value adding activities in the current project delivery process that uses BIM partially in Singapore are identified by comparing the typical current process with full BIM-based processes; such activities are cut down after process transformation in terms of people, process, and technology. Secondly, time savings derived from reducing the wastes caused by these activities are quantified. The proposed framework was validated by a case study of a local residential project. It was concluded that this framework provides a valuable tool for project teams to enhance productivity performance.

  18. Final report of the project performance assessment and economic evaluation of nuclear waste management

    International Nuclear Information System (INIS)

    Rasilainen, K.; Anttila, M.; Hautojaervi, A.

    1993-05-01

    The publication is the final report of project Performance Assessment and Economic Evaluation of Nuclear Waste Management (TOKA) at the Nuclear Engineering Laboratory of VTT (Technical Research Centre of Finland), forming part of the Publicly Financed Nuclear Waste Management Research Programme (JYT). The project covers safety and cost aspects of all phases of nuclear waste management. The main emphasis has been on developing an integrated system of models for performance assessment of nuclear waste repositories. During the four years the project has so far been in progress, the total amount of work has been around 14 person-years. Computer codes are the main tools in the project, they are either developed by the project team or acquired from abroad. In-house model development has been especially active in groundwater flow, near-field and migration modelling. The quantitative interpretation of Finnish tracer experiments in the laboratory and natural analogue studies at Palmottu support performance assessments via increased confidence in the migration concepts used. The performance assessment philosophy adopted by the team consists of deterministic modelling and pragmatic scenario analysis. This is supported by the long-term experience in practical performance assessment of the team, and in theoretical probabilistic modelling exercises. The radiological risks of spent fuel transportation from the Loviisa nuclear power plant to Russia have been analysed using a probabilistic computer code and Finnish traffic accident statistics. The project assists the authorities in the annual assessment of utility estimates of funding needs for future nuclear waste management operations. The models and methods used within the project are tested in international verification/validation projects

  19. Diagnostic performance of indirect MR arthrography for the diagnosis of rotator cuff tears at 3.0 T.

    Science.gov (United States)

    Lee, Ji Hyun; Yoon, Young Cheol; Jee, Sukkyung

    2015-06-01

    Indirect magnetic resonance (MR) arthrography is a non-invasive method for shoulder imaging. However, there are no studies that have examined the diagnostic performance of indirect MR arthrography for the diagnosis of rotator cuff tears in a large patient population. To assess the diagnostic performance of indirect fast spin-echo (FSE) MR arthrography for the diagnosis of rotator cuff tears at 3.0 T. A total of 149 patients who had undergone indirect shoulder MR arthrography followed by arthroscopic surgery were enrolled in this retrospective study. Two musculoskeletal radiologists evaluated images from each patient for the presence of supraspinatus-infraspinatus (SSP-ISP) or subscapularis (SSC) tendon tears. Using the arthroscopic findings as the reference standard, the overall diagnostic performance and detection rates for SSP-ISP and SSC tendon tears were calculated. The sensitivity, specificity, and accuracy of readers I and II for the diagnosis of SSP-ISP tendon tears were 94% and 95%, 89% and 85%, and 93% and 93%, respectively. The sensitivity of imaging for detection of SSP-ISP tendon tears by readers I and II were 100% and 100% for full-thickness tears and 84% and 86% for partial-thickness tears, respectively. The sensitivity, specificity, and accuracy of readers I and II for the diagnosis of SSC tendon tears were 80% and 76%, 89% and 93%, and 85% and 85%, respectively. Indirect MR arthrography is useful for the detection of SSP-ISP and SSC tendon tears. © The Foundation Acta Radiologica 2014 Reprints and permissions: sagepub.co.uk/journalsPermissions.nav.

  20. Performance of a real-time PCR assay in routine bovine mastitis diagnostics compared with in-depth conventional culture.

    Science.gov (United States)

    Hiitiö, Heidi; Riva, Rauna; Autio, Tiina; Pohjanvirta, Tarja; Holopainen, Jani; Pyörälä, Satu; Pelkonen, Sinikka

    2015-05-01

    Reliable identification of the aetiological agent is crucial in mastitis diagnostics. Real-time PCR is a fast, automated tool for detecting the most common udder pathogens directly from milk. In this study aseptically taken quarter milk samples were analysed with a real-time PCR assay (Thermo Scientific PathoProof Mastitis Complete-12 Kit, Thermo Fisher Scientific Ltd.) and by semi-quantitative, in-depth bacteriological culture (BC). The aim of the study was to evaluate the diagnostic performance of the real-time PCR assay in routine use. A total of 294 quarter milk samples from routine mastitis cases were cultured in the national reference laboratory of Finland and examined with real-time PCR. With BC, 251 out of 294 (85.7%) of the milk samples had at least one colony on the plate and 38 samples were considered contaminated. In the PCR mastitis assay, DNA of target species was amplified in 244 samples out of 294 (83.0%). The most common bacterial species detected in the samples, irrespective of the diagnostic method, was the coagulase negative staphylococci (CNS) group (later referred as Staphylococcus spp.) followed by Staphylococcus aureus. Sensitivity (Se) and specificity (Sp) for the PCR assay to provide a positive Staph. aureus result was 97.0 and 95.8% compared with BC. For Staphylococcus spp., the corresponding figures were 86.7 and 75.4%. Our results imply that PCR performed well as a diagnostic tool to detect Staph. aureus but may be too nonspecific for Staphylococcus spp. in routine use with the current cut-off Ct value (37.0). Using PCR as the only microbiological method for mastitis diagnostics, clinical relevance of the results should be carefully considered before further decisions, for instance antimicrobial treatment, especially when minor pathogens with low amount of DNA have been detected. Introducing the concept of contaminated samples should also be considered.

  1. The Hybrid Management Model: Influences of Organizational Structure and IT Project Management Practices on the Performance of Federal IT Projects

    Science.gov (United States)

    Neves, Celine A.

    2012-01-01

    The federal government spends much money on information technology (IT) projects each year, yet numerous IT projects continue to underperform. For instance, in Fiscal Year 2008, OMB and federal agencies identified approximately 413 IT projects ($25.2 billion) as being poorly planned, poorly performing, or both. Agencies struggle to implement sound…

  2. Performance assessment of the PNM Prosperity electricity storage project

    Energy Technology Data Exchange (ETDEWEB)

    Roberson, Dakota [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Ellison, James F. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Bhatnagar, Dhruv [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Schoenwald, David A. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)

    2014-05-01

    The purpose of this study is to characterize the technical performance of the PNM Prosperity electricity storage project, and to identify lessons learned that can be used to improve similar projects in the future. The PNM Prosperity electricity storage project consists of a 500 kW/350 kWh advanced lead-acid battery with integrated supercapacitor (for energy smoothing) and a 250 kW/1 MWh advanced lead-acid battery (for energy shifting), and is co-located with a 500 kW solar photovoltaic (PV) resource. The project received American Reinvestment and Recovery Act (ARRA) funding. The smoothing system is e ective in smoothing intermittent PV output. The shifting system exhibits good round-trip efficiencies, though the AC-to-AC annual average efficiency is lower than one might hope. Given the current utilization of the smoothing system, there is an opportunity to incorporate additional control algorithms in order to increase the value of the energy storage system.

  3. Flowfield modeling and diagnostics

    International Nuclear Information System (INIS)

    Gupta, A.K.; Lilley, D.G.

    1985-01-01

    This textbook is devoted solely to flowfield modeling and diagnostics; their practical use, recent and current research, and projected developments and trends. It provides an account of the use of a broad range of techniques in industrial and research practice, both with and without combustion. Application ideas are complemented by details about experimental and modeling techniques

  4. Comparison of the diagnostic performance of digital breast tomosynthesis and magnetic resonance imaging added to digital mammography in women with known breast cancers

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Won Hwa; Chang, Jung Min; Moon, Woo Kyung [Seoul National University Hospital, Department of Radiology, 101 Daehangno, Jongno-gu, Seoul (Korea, Republic of); Moon, Hyeong-Gon [Seoul National University Hospital, Department of Surgery, Seoul (Korea, Republic of); Yi, Ann [Seoul National University Hospital, Department of Radiology, Gangnan Healthcare Center, Seoul (Korea, Republic of); Koo, Hye Ryoung [Hanyang University College of Medicine, Department of Radiology, Seoul (Korea, Republic of); Gweon, Hye Mi [Yonsei University College of Medicine, Department of Radiology, Gangnam Severance Hospital, Seoul (Korea, Republic of)

    2016-06-15

    To compare the diagnostic performance of digital breast tomosynthesis (DBT) and magnetic resonance imaging (MRI) added to mammography in women with known breast cancers. Three radiologists independently reviewed image sets of 172 patients with 184 cancers; mammography alone, DBT plus mammography and MRI plus mammography, and scored for cancer probability using the Breast Imaging Reporting and Data System (BI-RADS). Jack-knife alternative free-response receiver-operating characteristic (JAFROC), which allows diagnostic performance estimation using single lesion as a statistical unit in a cancer-only population, was used. Sensitivity and positive predictive value (PPV) were compared using the McNemar and Fisher-exact tests. The JAFROC figures of merit (FOMs) was lower in DBT plus mammography (0.937) than MRI plus mammography (0.978, P = 0.0006) but higher than mammography alone (0.900, P = 0.0013). The sensitivity was lower in DBT plus mammography (88.2 %) than MRI plus mammography (97.8 %) but higher than mammography alone (78.3 %, both P < 0.0001). The PPV was significantly higher in DBT plus mammography (93.3 %) than MRI plus mammography (89.6 %, P = 0.0282). DBT provided lower diagnostic performance than MRI as an adjunctive imaging to mammography. However, DBT had higher diagnostic performance than mammography and higher PPV than MRI. (orig.)

  5. Comparison of the diagnostic performance of digital breast tomosynthesis and magnetic resonance imaging added to digital mammography in women with known breast cancers

    International Nuclear Information System (INIS)

    Kim, Won Hwa; Chang, Jung Min; Moon, Woo Kyung; Moon, Hyeong-Gon; Yi, Ann; Koo, Hye Ryoung; Gweon, Hye Mi

    2016-01-01

    To compare the diagnostic performance of digital breast tomosynthesis (DBT) and magnetic resonance imaging (MRI) added to mammography in women with known breast cancers. Three radiologists independently reviewed image sets of 172 patients with 184 cancers; mammography alone, DBT plus mammography and MRI plus mammography, and scored for cancer probability using the Breast Imaging Reporting and Data System (BI-RADS). Jack-knife alternative free-response receiver-operating characteristic (JAFROC), which allows diagnostic performance estimation using single lesion as a statistical unit in a cancer-only population, was used. Sensitivity and positive predictive value (PPV) were compared using the McNemar and Fisher-exact tests. The JAFROC figures of merit (FOMs) was lower in DBT plus mammography (0.937) than MRI plus mammography (0.978, P = 0.0006) but higher than mammography alone (0.900, P = 0.0013). The sensitivity was lower in DBT plus mammography (88.2 %) than MRI plus mammography (97.8 %) but higher than mammography alone (78.3 %, both P < 0.0001). The PPV was significantly higher in DBT plus mammography (93.3 %) than MRI plus mammography (89.6 %, P = 0.0282). DBT provided lower diagnostic performance than MRI as an adjunctive imaging to mammography. However, DBT had higher diagnostic performance than mammography and higher PPV than MRI. (orig.)

  6. [Treatment of Hallux Valgus: Current Diagnostic Testing and Surgical Treatment Performed by German Foot and Ankle Surgeons].

    Science.gov (United States)

    Arbab, Dariusch; Schneider, Lisa-Maria; Schnurr, Christoph; Bouillon, Bertil; Eysel, Peer; König, Dietmar Pierre

    2018-04-01

    Hallux valgus is one of the most prevalent foot deformities, and surgical treatment of Hallux valgus is one of the most common procedures in foot and ankle surgery. Diagnostic and treatment standards show large variation despite medical guidelines and national foot and ankle societies. The aim of this nationwide survey is a description of the current status of diagnostics and therapy of Hallux valgus in Germany. A nationwide online questionnaire survey was sent to two German foot and ankle societies. The participants were asked to answer a questionnaire of 53 questions with four subgroups (general, diagnostics, operation, preoperative management). Surgical treatment for three clinical cases demonstrating a mild, moderate and severe Hallux valgus deformity was inquired. 427 foot and ankle surgeons answered the questionnaire. 388 participants were certified foot and ankle surgeons from one or both foot and ankle societies. Medical history (78%), preoperative radiographs (100%) and preoperative radiographic management (78%) are of high or very high importance for surgical decision pathway. Outcome scores are used by less than 20% regularly. Open surgery is still the gold standard, whereas minimally invasive surgery is performed by only 7%. Our survey showed that diagnostic standards are met regularly. There is a wide variation in the type of procedures used to treat Hallux valgus deformity. TMT I arthrodesis is preferred in severe Hallux valgus, but also used to treat moderate and mild deformities. Minimally invasive surgery is still used by a minority of surgeons. It remains to be seen, to what extent minimally invasive surgery will be performed in the future. Georg Thieme Verlag KG Stuttgart · New York.

  7. SU-F-E-01: Pitfalls: Reliability and Performance of Diagnostic X-Sources

    Energy Technology Data Exchange (ETDEWEB)

    Behling, R [Philips Medical Systems DMC GmbHHamburg (United States)

    2016-06-15

    Purpose: Performance and reliability of medical X-ray tubes for imaging are crucial from an ethical, clinical and economic perspective. This lecture will deliver insight into the aspects to consider during the decision making process to invest in X-ray imaging equipment. Outdated metric still hampers realistic product comparison. It is time to change this and to comply with latest standards, which consider current technology. Failure modes and ways to avoid down-time of the equipment shall be discussed. In view of the increasing number of interventional procedures and the hazards associated with ionizing radiation, toxic contrast agents, and the combination thereof, the aspect of system reliability is of paramount importance. Methods: A comprehensive picture of trends for different modalities (CT, angiography, general radiology) has been drawn and led to the development of novel X-ray tube technology. Results: Recent X-ray tubes feature enhanced reliability and unprecedented performance. Relevant metrics for product comparison still have to be implemented in practice. Conclusion: The speed of scientific and industrial development of new diagnostic and therapeutic X-ray sources remains tremendous. Still, users suffer from gaps between desire and reality in day-to-day diagnostic routine. X-ray sources are still limiting cutting-edge medical procedures. Side-effects of wear and tear, limitations of the clinical work flow, costs, the characteristics of the X-ray spectrum and others topics need to be further addressed. New applications and modalities, like detection-based color-resolved X-ray and phase-contrast / dark-field imaging will impact the course of new developments of X-ray sources. The author is employee of Royal Philips.

  8. SU-F-E-01: Pitfalls: Reliability and Performance of Diagnostic X-Sources

    International Nuclear Information System (INIS)

    Behling, R

    2016-01-01

    Purpose: Performance and reliability of medical X-ray tubes for imaging are crucial from an ethical, clinical and economic perspective. This lecture will deliver insight into the aspects to consider during the decision making process to invest in X-ray imaging equipment. Outdated metric still hampers realistic product comparison. It is time to change this and to comply with latest standards, which consider current technology. Failure modes and ways to avoid down-time of the equipment shall be discussed. In view of the increasing number of interventional procedures and the hazards associated with ionizing radiation, toxic contrast agents, and the combination thereof, the aspect of system reliability is of paramount importance. Methods: A comprehensive picture of trends for different modalities (CT, angiography, general radiology) has been drawn and led to the development of novel X-ray tube technology. Results: Recent X-ray tubes feature enhanced reliability and unprecedented performance. Relevant metrics for product comparison still have to be implemented in practice. Conclusion: The speed of scientific and industrial development of new diagnostic and therapeutic X-ray sources remains tremendous. Still, users suffer from gaps between desire and reality in day-to-day diagnostic routine. X-ray sources are still limiting cutting-edge medical procedures. Side-effects of wear and tear, limitations of the clinical work flow, costs, the characteristics of the X-ray spectrum and others topics need to be further addressed. New applications and modalities, like detection-based color-resolved X-ray and phase-contrast / dark-field imaging will impact the course of new developments of X-ray sources. The author is employee of Royal Philips

  9. Emergency CT brain: preliminary interpretation with a tablet device: image quality and diagnostic performance of the Apple iPad.

    LENUS (Irish Health Repository)

    Mc Laughlin, Patrick

    2012-04-01

    Tablet devices have recently been used in radiological image interpretation because they have a display resolution comparable to desktop LCD monitors. We identified a need to examine tablet display performance prior to their use in preliminary interpretation of radiological images. We compared the spatial and contrast resolution of a commercially available tablet display with a diagnostic grade 2 megapixel monochrome LCD using a contrast detail phantom. We also recorded reporting discrepancies, using the ACR RADPEER system, between preliminary interpretation of 100 emergency CT brain examinations on the tablet display and formal review on a diagnostic LCD. The iPad display performed inferiorly to the diagnostic monochrome display without the ability to zoom. When the software zoom function was enabled on the tablet device, comparable contrast detail phantom scores of 163 vs 165 points were achieved. No reporting discrepancies were encountered during the interpretation of 43 normal examinations and five cases of acute intracranial hemorrhage. There were seven RADPEER2 (understandable) misses when using the iPad display and 12 with the diagnostic LCD. Use of software zoom in the tablet device improved its contrast detail phantom score. The tablet allowed satisfactory identification of acute CT brain findings, but additional research will be required to examine the cause of "understandable" reporting discrepancies that occur when using tablet devices.

  10. Telecontrol - Expert systems. Real-time monitoring and remote diagnostic

    Energy Technology Data Exchange (ETDEWEB)

    Lam, A.

    1996-09-01

    The role of expert systems in programming simple and complex tasks in utilities companies was discussed with examples from B.C. Hydro, where expert systems have been used in such diverse applications as an in-house programmable logic controller (PLC) training course, and a machine audit on a 150 MW steam turbine generating unit at their Burrard Thermal Generating Plant. The PLC tutoring program uses expert system technology for the air blast circuit breakers` air drier system, for individualized on-site training. The steam turbine audits (an eight-month long project) were performed remotely by dialing an on-site computer configured with customized expert software. Details of these, and other potential applications, such as transformer monitoring and diagnostics, circuit breaker performance analysis, and information management, were described.

  11. Iterative reconstruction technique with reduced volume CT dose index: diagnostic accuracy in pediatric acute appendicitis

    Energy Technology Data Exchange (ETDEWEB)

    Didier, Ryne A. [Oregon Health and Science University, Department of Diagnostic Radiology, DC7R, Portland, OR (United States); Vajtai, Petra L. [Oregon Health and Science University, Department of Pediatrics, Portland, OR (United States); Oregon Health and Science University, Department of Diagnostic Radiology, DC7R, Portland, OR (United States); Hopkins, Katharine L. [Oregon Health and Science University, Department of Diagnostic Radiology, DC7R, Portland, OR (United States); Oregon Health and Science University, Department of Pediatrics, Portland, OR (United States)

    2014-07-05

    Iterative reconstruction technique has been proposed as a means of reducing patient radiation dose in pediatric CT. Yet, the effect of such reductions on diagnostic accuracy has not been thoroughly evaluated. This study compares accuracy of diagnosing pediatric acute appendicitis using contrast-enhanced abdominopelvic CT scans performed with traditional pediatric weight-based protocols and filtered back projection reconstruction vs. a filtered back projection/iterative reconstruction technique blend with reduced volume CT dose index (CTDI{sub vol}). Results of pediatric contrast-enhanced abdominopelvic CT scans done for pain and/or suspected appendicitis were reviewed in two groups: A, 192 scans performed with the hospital's established weight-based CT protocols and filtered back projection reconstruction; B, 194 scans performed with iterative reconstruction technique and reduced CTDI{sub vol}. Reduced CTDI{sub vol} was achieved primarily by reductions in effective tube current-time product (mAs{sub eff}) and tube peak kilovoltage (kVp). CT interpretation was correlated with clinical follow-up and/or surgical pathology. CTDI{sub vol}, size-specific dose estimates (SSDE) and performance characteristics of the two CT techniques were then compared. Between groups A and B, mean CTDI{sub vol} was reduced by 45%, and mean SSDE was reduced by 46%. Sensitivity, specificity and diagnostic accuracy were 96%, 97% and 96% in group A vs. 100%, 99% and 99% in group B. Accuracy in diagnosing pediatric acute appendicitis was maintained in contrast-enhanced abdominopelvic CT scans that incorporated iterative reconstruction technique, despite reductions in mean CTDI{sub vol} and SSDE by nearly half as compared to the hospital's traditional weight-based protocols. (orig.)

  12. [Advances of Molecular Diagnostic Techniques Application in Clinical Diagnosis.

    Science.gov (United States)

    Ying, Bin-Wu

    2016-11-01

    Over the past 20 years,clinical molecular diagnostic technology has made rapid development,and became the most promising field in clinical laboratory medicine.In particular,with the development of genomics,clinical molecular diagnostic methods will reveal the nature of clinical diseases in a deeper level,thus guiding the clinical diagnosis and treatments.Many molecular diagnostic projects have been routinely applied in clinical works.This paper reviews the advances on application of clinical diagnostic techniques in infectious disease,tumor and genetic disorders,including nucleic acid amplification,biochip,next-generation sequencing,and automation molecular system,and so on.

  13. Diagnostic performance of a Lattice Boltzmann-based method for CT-based fractional flow reserve.

    Science.gov (United States)

    Giannopoulos, Andreas A; Tang, Anji; Ge, Yin; Cheezum, Michael K; Steigner, Michael L; Fujimoto, Shinichiro; Kumamaru, Kanako K; Chiappino, Dante; Della Latta, Daniele; Berti, Sergio; Chiappino, Sara; Rybicki, Frank J; Melchionna, Simone; Mitsouras, Dimitrios

    2018-02-20

    Fractional flow reserve (FFR) estimated from coronary computed tomography angiography (CT-FFR) offers non-invasive detection of lesion-specific ischaemia. We aimed to develop and validate a fast CT-FFR algorithm utilising the Lattice Boltzmann method for blood flow simulation (LBM CT-FFR). Sixty-four patients with clinically indicated CTA and invasive FFR measurement from three institutions were retrospectively analysed. CT-FFR was performed using an onsite tool interfacing with a commercial Lattice Boltzmann fluid dynamics cloud-based platform. Diagnostic accuracy of LBM CT-FFR ≤0.8 and percent diameter stenosis >50% by CTA to detect invasive FFR ≤0.8 were compared using area under the receiver operating characteristic curve (AUC). Sixty patients successfully underwent LBM CT-FFR analysis; 29 of 73 lesions in 69 vessels had invasive FFR ≤0.8. Total time to perform LBM CT-FFR was 40±10 min. Compared to invasive FFR, LBM CT-FFR had good correlation (r=0.64), small bias (0.009) and good limits of agreement (-0.223 to 0.206). The AUC of LBM CT-FFR (AUC=0.894, 95% confidence interval [CI]: 0.792-0.996) was significantly higher than CTA (AUC=0.685, 95% CI: 0.576-0.794) to detect FFR ≤0.8 (p=0.0021). Per-lesion specificity, sensitivity, and accuracy of LBM CT-FFR were 97.7%, 79.3%, and 90.4%, respectively. LBM CT-FFR has very good diagnostic accuracy to detect lesion-specific ischaemia (FFR ≤0.8) and can be performed in less than one hour.

  14. Diagnostics for PLX-alpha

    Science.gov (United States)

    Gilmore, Mark; Hsu, Scott

    2015-11-01

    The goal of the Plasma Liner eXperiment PLX-alpha at Los Alamos National Laboratory is to establish the viability of creating a spherically imploding plasma liner for MIF and HED applications, using a spherical array of supersonic plasma jets launched by innovative contoured-gap coaxial plasma guns. PLX- α experiments will focus in particular on establishing the ram pressure and uniformity scalings of partial and fully spherical plasma liners. In order to characterize these parameters experimentally, a suite of diagnostics is planned, including multi-camera fast imaging, a 16-channel visible interferometer (upgraded from 8 channels) with reconfigurable, fiber-coupled front end, and visible and VUV high-resolution and survey spectroscopy. Tomographic reconstruction and data fusion techniques will be used in conjunction with interferometry, imaging, and synthetic diagnostics from modeling to characterize liner uniformity in 3D. Diagnostic and data analysis design, implementation, and status will be presented. Supported by the Advanced Research Projects Agency - Energy - U.S. Department of Energy.

  15. Use of proficiency samples to assess diagnostic laboratories in France performing a Trichinella digestion assay.

    Science.gov (United States)

    Vallée, Isabelle; Macé, Pauline; Forbes, Lorry; Scandrett, Brad; Durand, Benoit; Gajadhar, Alvin; Boireau, Pascal

    2007-07-01

    Routine diagnosis of animal trichinellosis for food safety and trade relies on a method of artificial digestion to free Trichinella muscle larvae from meat for subsequent identification by microscopy. As part of a quality control system, the French National Reference Laboratory (NRL) initiated ring trials to determine the sensitivity of the test performed in the 72 routine diagnostic laboratories in France. A method was devised to obtain calibrated meat samples containing known numbers of capsules with Trichinella spiralis muscle larvae. This method was based on an incomplete artificial digestion of Trichinella-infected mice carcasses to allow the collection of intact Trichinella capsules. Capsules were placed into a meatball of 100 +/- 2 g of pork and horsemeat to produce proficiency samples. Three categories of samples were prepared: small (3 to 5 capsules), medium (7 to 10), and large (12 to 15). The sensitivity was expressed as the percentage of muscle larvae recovered from each proficiency sample. Reproducibility was tested with ring trials organized between two NRLs (France and Canada), and a reference sensitivity of 84.9% was established. National ring trials were then organized in France, with the 72 routine diagnostic laboratories each receiving four proficiency samples per session. After five sessions, an improvement in the digest test sensitivity was observed. Results at the fifth session indicated sensitivities of 78.60% +/- 23.70%, 81.19% +/- 19.59%, and 80.52% +/- 14.71% muscle larvae for small, medium, and large samples, respectively. This study supports the use of proficiency samples to accurately evaluate the performance of routine diagnostic laboratories that conduct digestion tests for animal trichinellosis diagnosis.

  16. Effect of breast cancer phenotype on diagnostic performance of MRI in the prediction to response to neoadjuvant treatment

    Energy Technology Data Exchange (ETDEWEB)

    Bufi, Enida, E-mail: reagandus@alice.it [Department of Bioimaging and Radiological Sciences, Catholic University, Rome (Italy); Belli, Paolo; Di Matteo, Marialuisa [Department of Bioimaging and Radiological Sciences, Catholic University, Rome (Italy); Terribile, Daniela; Franceschini, Gianluca [Department of Surgery, Breast Unit, Catholic University, Rome (Italy); Nardone, Luigia [Department of Radiotherapy, Catholic University, Rome (Italy); Petrone, Gianluigi [Department of Pathology, Catholic University, Rome (Italy); Bonomo, Lorenzo [Department of Bioimaging and Radiological Sciences, Catholic University, Rome (Italy)

    2014-09-15

    Aim: The estimation of response to neoadjuvant chemotherapy (NAC) is useful in the surgical decision in breast cancer. We addressed the diagnostic reliability of conventional MRI, of diffusion weighted imaging (DWI) and of a merged criterion coupling morphological MRI and DWI. Diagnostic performance was analysed separately in different tumor subtypes, including HER2+ (human epidermal growth factor receptor 2)/HR+ (hormone receptor) (hybrid phenotype). Materials and methods: Two-hundred and twenty-five patients underwent MRI before and after NAC. The response to treatment was defined according to the RECIST classification and the evaluation of DWI with apparent diffusion coefficient (ADC). The complete pathological response – pCR was assessed (Mandard classification). Results: Tumor phenotypes were Luminal (63.6%), Triple Negative (16.4%), HER2+ (7.6%) or Hybrid (12.4%). After NAC, pCR was observed in 17.3% of cases. Average ADC was statistically higher after NAC (p < 0.001) among patients showing pCR vs. those who had not pCR. The RECIST classification showed adequate performance in predicting the pCR in Triple Negative (area under the receiver operating characteristic curve, ROC AUC = 0.9) and in the HER2+ subgroup (AUC = 0.826). Lower performance was found in the Luminal and Hybrid subgroups (AUC 0.693 and 0.611, respectively), where the ADC criterion yielded an improved performance (AUC = 0.787 and 0.722). The coupling of morphological and DWI criteria yielded maximally improved performance in the Luminal and Hybrid subgroups (AUC = 0.797 and 0.761). Conclusion: The diagnostic reliability of MRI in predicting the pCR to NAC depends on the tumor phenotype, particularly in the Luminal and Hybrid subgroups. In these cases, the coupling of morphological MRI evaluation and DWI assessment may facilitate the diagnosis.

  17. Comparison of SPECT/CT and MRI in diagnosing symptomatic lesions in ankle and foot pain patients: diagnostic performance and relation to lesion type.

    Science.gov (United States)

    Ha, Seunggyun; Hong, Sung Hwan; Paeng, Jin Chul; Lee, Dong Yeon; Cheon, Gi Jeong; Arya, Amitabh; Chung, June-Key; Lee, Dong Soo; Kang, Keon Wook

    2015-01-01

    The purpose of this study was to compare the diagnostic performance of SPECT/CT and MRI in patients with ankle and foot pain, with regard to the lesion types. Fifty consecutive patients with ankle and foot pain, who underwent 99mTc-MDP SPECT/CT and MRI, were retrospectively enrolled in this study. Symptomatic lesions were determined based on clinical examination and response to treatment. On MRI and SPECT/CT, detected lesions were classified as bone, ligament/tendon, and joint lesions. Uptake on SPECT/CT was assessed using a 4-grade system. Sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) of SPECT/CT and MRI were evaluated in all detected lesions and each lesion type. Diagnostic value of uptake grade was analyzed using receiver-operating characteristics (ROC) curve analysis, and diagnostic performance was compared using Chi-square or McNemar tests. In overall lesions, the sensitivity, PPV and NPV of SPECT/CT for symptomatic lesions were 93%, 56%, 91%, and they were 98%, 48%, 95% for MRI. There was no significant difference between SPECT/CT and MRI. However, the specificity of SPECT/CT was significantly higher than that of MRI (48% versus 24%, P = 0.016). Uptake grade on SPECT/CT was significantly higher in symptomatic lesions (P diagnostic performance for symptomatic lesions in ankle and foot pain patients. SPECT/CT and MRI exhibit different diagnostic specificity in different lesion types. SPECT/CT may be used as a complementary imaging method to MRI for enhancing diagnostic specificity.

  18. Electronic DNA detection and diagnostics

    NARCIS (Netherlands)

    De, Arpita

    2013-01-01

    The Nanopill project is an ambitious undertaking with the objective to develop an early-warning cancer diagnostic pill that is ingested by the patient. The Nanopill collects intestinal fluid as the pill travels down the intestinal tract, and tests for the presence of a free floating hyper-methylated

  19. IMPLEMENTATION OF TURNOUTS TECHNICAL DIAGNOSTICS SYSTEMS

    Directory of Open Access Journals (Sweden)

    S. YU. Buryak

    2015-06-01

    Full Text Available Purpose. In the paper it is necessary to: 1 find out the causes of turnouts faults to determine diagnostic features failures; 2 consider the requirements structure, purpose components of turnouts, work and technology of their maintenance to determine the construction of the economic activities related to system to the turnout’s maintenance; 3 substantiate the possibility, necessity and prospects of automated diagnostics turnout’s implementation; 4 elaborate a prototype of an automated hardware and software system for the turnouts control parameters and perform diagnostics on them. Methodology. In the paper possible turnouts faults were presented and manifestations and influence on its work were shown. According to the current technology works the process analyze of turnouts’ maintenance was conducted, were defined the basic performed operations during the examination of appearance, parameters and check the repair or replacement of parts and assemblies. Based on the analysis of reasons of turnouts malfunctioning and their fixes were systematized types of damages and ways to deal with them, an information scheme of troubleshooting were created, opportunities and limits of automating the process of diagnostics were identified and compared with the existing method of turnouts maintenance. A diagnostics system block diagram was created, an algorithm of its work was developed and established main basic principles of operation. Software and hardware to determine the turnout’s state considering diagnostic performance of points in use were applied. Findings. During the experiment was created a method of automated turnout’s diagnostics with AC electric drives, managed centrally. The results of automated hardware and software system make it possible to control turnout’s parameters and perform diagnostics on them. Originality. Authors created the method of turnout’s state determination by current curve and its spectral composition in the

  20. Bayesian tomography and integrated data analysis in fusion diagnostics

    Science.gov (United States)

    Li, Dong; Dong, Y. B.; Deng, Wei; Shi, Z. B.; Fu, B. Z.; Gao, J. M.; Wang, T. B.; Zhou, Yan; Liu, Yi; Yang, Q. W.; Duan, X. R.

    2016-11-01

    In this article, a Bayesian tomography method using non-stationary Gaussian process for a prior has been introduced. The Bayesian formalism allows quantities which bear uncertainty to be expressed in the probabilistic form so that the uncertainty of a final solution can be fully resolved from the confidence interval of a posterior probability. Moreover, a consistency check of that solution can be performed by checking whether the misfits between predicted and measured data are reasonably within an assumed data error. In particular, the accuracy of reconstructions is significantly improved by using the non-stationary Gaussian process that can adapt to the varying smoothness of emission distribution. The implementation of this method to a soft X-ray diagnostics on HL-2A has been used to explore relevant physics in equilibrium and MHD instability modes. This project is carried out within a large size inference framework, aiming at an integrated analysis of heterogeneous diagnostics.

  1. Comparative Laser Spectroscopy Diagnostics for Ancient Metallic Artefacts Exposed to Environmental Pollution

    Directory of Open Access Journals (Sweden)

    Łukasz Ciupiński

    2010-05-01

    Full Text Available Metal artworks are subjected to corrosion and oxidation processes due to reactive agents present in the air, water and in the ground that these objects have been in contact with for hundreds of years. This is the case for archaeological metals that are recovered from excavation sites, as well as artefacts exposed to polluted air. Stabilization of the conservation state of these objects needs precise diagnostics of the accrued surface layers and identification of original, historical materials before further protective treatments, including safe laser cleaning of unwanted layers. This paper presents analyses of the chemical composition and stratigraphy of corrosion products with the use of laser induced breakdown spectroscopy (LIBS and Raman spectroscopy. The discussion of the results is supported by material studies (SEM-EDS, XRF, ion-analyses. The tests were performed on several samples taken from original objects, including copper roofing from Wilanów Palace in Warsaw and Karol Poznański Palace in Łódź, bronze decorative figures from the Wilanów Palace gardens, and four archaeological examples of old jewellery (different copper alloys. Work has been performed as a part of the MATLAS project in the frames of EEA and Norway Grants (www.matlas.eu and the results enable the comparison of the methodology and to elaborate the joint diagnostic procedures of the three project partner independent laboratories.

  2. Comparative Laser Spectroscopy Diagnostics for Ancient Metallic Artefacts Exposed to Environmental Pollution

    Science.gov (United States)

    Ciupiński, Łukasz; Fortuna-Zaleśna, Elżbieta; Garbacz, Halina; Koss, Andrzej; Kurzydłowski, Krzysztof J.; Marczak, Jan; Mróz, Janusz; Onyszczuk, Tomasz; Rycyk, Antoni; Sarzyński, Antoni; Skrzeczanowski, Wojciech; Strzelec, Marek; Zatorska, Anna; Żukowska, Grażyna Z.

    2010-01-01

    Metal artworks are subjected to corrosion and oxidation processes due to reactive agents present in the air, water and in the ground that these objects have been in contact with for hundreds of years. This is the case for archaeological metals that are recovered from excavation sites, as well as artefacts exposed to polluted air. Stabilization of the conservation state of these objects needs precise diagnostics of the accrued surface layers and identification of original, historical materials before further protective treatments, including safe laser cleaning of unwanted layers. This paper presents analyses of the chemical composition and stratigraphy of corrosion products with the use of laser induced breakdown spectroscopy (LIBS) and Raman spectroscopy. The discussion of the results is supported by material studies (SEM-EDS, XRF, ion-analyses). The tests were performed on several samples taken from original objects, including copper roofing from Wilanów Palace in Warsaw and Karol Poznański Palace in ŁódŸ, bronze decorative figures from the Wilanów Palace gardens, and four archaeological examples of old jewellery (different copper alloys). Work has been performed as a part of the MATLAS project in the frames of EEA and Norway Grants (www.matlas.eu) and the results enable the comparison of the methodology and to elaborate the joint diagnostic procedures of the three project partner independent laboratories. PMID:22399915

  3. Diagnostic performance of stress myocardial perfusion imaging for coronary artery disease: a systematic review and meta-analysis

    International Nuclear Information System (INIS)

    Jong, Marcus C. de; Genders, Tessa S.S.; Geuns, Robert-Jan van; Moelker, Adriaan; Hunink, M.G.M.

    2012-01-01

    To determine and compare the diagnostic performance of stress myocardial perfusion imaging (MPI) for the diagnosis of obstructive coronary artery disease (CAD), using conventional coronary angiography (CCA) as the reference standard. We searched Medline and Embase for literature that evaluated stress MPI for the diagnosis of obstructive CAD using magnetic resonance imaging (MRI), contrast-enhanced echocardiography (ECHO), single-photon emission computed tomography (SPECT) and positron emission tomography (PET). All pooled analyses were based on random effects models. Articles on MRI yielded a total of 2,970 patients from 28 studies, articles on ECHO yielded a sample size of 795 from 10 studies, articles on SPECT yielded 1,323 from 13 studies. For CAD defined as either at least 50 %, at least 70 % or at least 75 % lumen diameter reduction on CCA, the natural logarithms of the diagnostic odds ratio (lnDOR) for MRI (3.63; 95 % CI 3.26-4.00) was significantly higher compared to that of SPECT (2.76; 95 % CI 2.28-3.25; P = 0.006) and that of ECHO (2.83; 95 % CI 2.29-3.37; P = 0.02). There was no significant difference between the lnDOR of SPECT and ECHO (P = 0.52). Our results suggest that MRI is superior for the diagnosis of obstructive CAD compared with ECHO and SPECT. ECHO and SPECT demonstrated similar diagnostic performance. (orig.)

  4. Diagnostic performance of tumor markers AFP and PIVKA-II in Chinese hepatocellular carcinoma patients.

    Science.gov (United States)

    Huang, Shujing; Jiang, Feifei; Wang, Ying; Yu, Yanhua; Ren, Siqian; Wang, Xiaowei; Yin, Peng; Lou, Jinli

    2017-06-01

    Alpha-fetoprotein is an effective biomarker as an aid in hepatocellular carcinoma detection in many countries. However, alpha-fetoprotein has its limitations, especially in early hepatocellular carcinoma diagnosis. Protein induced by vitamin K absence or antagonist-II is another biomarker that is used for hepatocellular carcinoma detection. The aim of this study is to compare the diagnostic performance of alpha-fetoprotein and protein induced by vitamin K absence or antagonist-II alone and in combination to explore improving biomarker performance as an aid in early hepatocellular carcinoma detection. In this study a total of 582 serum samples including 132 hepatocellular carcinoma patients, 250 non-hepatocellular carcinoma patients, and 200 healthy volunteers were collected. Alpha-fetoprotein and protein induced by vitamin K absence or antagonist-II levels were measured by both chemiluminescent enzyme immunoassay on LUMIPULSE platform and by chemiluminescent microparticle immunoassay on ARCHITECT platform. Receiver operation characteristic curve analyses were performed for each biomarker and in combination. The results showed that Alpha-fetoprotein and protein induced by vitamin K absence or antagonist-II in combination have shown higher area under the curve compared to alpha-fetoprotein alone for diagnosis in whole patients (0.906 vs 0.870) in hepatocellular carcinoma early-stage patients (0.809 vs 0.77) and in hepatitis B virus-related hepatocellular carcinoma patients (0.851 vs 0.788) with ARCHITECT platform. Protein induced by vitamin K absence or antagonist-II showed higher area under the curve than alpha-fetoprotein for diagnosis of hepatitis B virus-related hepatocellular carcinoma patients (0.901 vs 0.788).We conclude that Combining alpha-fetoprotein and protein induced by vitamin K absence or antagonist-II may improve the diagnostic value for early detection of hepatocellular carcinoma. Protein induced by vitamin K absence or antagonist-II performs better

  5. Towards diagnostics for a fusion reactor

    International Nuclear Information System (INIS)

    Costley, A. E.

    2009-01-01

    The requirements for measurements on modern tokamak fusion plasmas are outlined, and the techniques and systems used to make the measurements, usually referred to as 'diagnostics', are introduced. The basics of three particular diagnostics - magnetics, neutron systems and a laser based optical system - are outlined as examples of modern diagnostic systems, and the implementation of these diagnostics on a current tokamak (JET) are described. The next major step in magnetic confinement fusion is the construction and operation of the International Thermonuclear Experimental Reactor (ITER), which is a joint project of China, Europe, Japan, India, Korea, the Russian Federation, and the United States. Construction has begun in Cadarache, France. It is expected that ITER will operate at the 500 MW level. Because of the harsh environment in the vacuum vessel where many diagnostic components are located, the development of diagnostics for ITER is a major challenge - arguably the most difficult challenge ever undertaken in the field of diagnostics. The main elements in the diagnostic step are outlined using the three chosen techniques as examples. Finally, the step beyond ITER to a demonstration reactor, DEMO, that is expected to produce several GWs of fusion power is considered and the impact on diagnostics outlined. It is shown that the applicability and development steps needed for the individual diagnostics techniques will differ. The challenges for DEMO diagnostics are substantial and a dedicated effort should be made to find and develop new techniques, and especially techniques appropriate to the DEMO environment. It is argued that the limitations and difficulties in diagnostics should be a consideration in the optimization and designs of DEMO. (author)

  6. Chest radiography with a shaped filter has no diagnostic advantage: Demonstration by observer performance tests

    International Nuclear Information System (INIS)

    Guilbeau, J.C.; Mazoyer, B.; Pruvost, P.; Verrey, B.; Grenier, P.

    1987-01-01

    The effectiveness of a shaped filter in improving the detection of mediastinal and retrocardiac abnormalities on 140-kV posteroanterior chest radiographs was measured by observer performance testing. The filtered and unfiltered radiographs of 50 patients were randomly selected from 1,000 radiographs obtained from 500 ambulatory or hospitalized patients and were independently read by five observers. Observer performance in detecting abnormalities in the central area was analyzed by receiver operating characteristic (ROC) techniques. The results indicate that the use of a filter has no significant diagnostic advantage, regardless of type or location of lesions over the mediastinum and the retrocardiac areas

  7. Tehachapi Wind Energy Storage Project - Technology Performance Report #3

    Energy Technology Data Exchange (ETDEWEB)

    Pinsky, Naum [Southern California Edison, Rosemead, CA (United States); O' Neill, Lori [Southern California Edison, Rosemead, CA (United States)

    2017-03-31

    The TSP is located at SCE’s Monolith Substation in Tehachapi, California. The 8 MW, 4 hours (32 MWh) BESS is housed in a 6,300 square foot facility and 2 x 4 MW/4.5 MVA smart inverters are on a concrete pad adjacent to the BESS facility. The project will evaluate the capabilities of the BESS to improve grid performance and assist in the integration of large-scale intermittent generation, e.g., wind. Project performance was measured by 13 specific operational uses: providing voltage support and grid stabilization, decreasing transmission losses, diminishing congestion, increasing system reliability, deferring transmission investment, optimizing renewable-related transmission, providing system capacity and resources adequacy, integrating renewable energy (smoothing), shifting wind generation output, frequency regulation, spin/non-spin replacement reserves, ramp management, and energy price arbitrage. Most of the operations either shift other generation resources to meet peak load and other electricity system needs with stored electricity, or resolve grid stability and capacity concerns that result from the interconnection of intermittent generation. SCE also demonstrated the ability of lithium ion battery storage to provide nearly instantaneous maximum capacity for supply-side ramp rate control to minimize the need for fossil fuel-powered back-up generation. The project began in October, 2010 and will continue through December, 2016.

  8. Magnetic resonance imaging-detected extramural venous invasion in rectal cancer before and after preoperative chemoradiotherapy. Diagnostic performance and prognostic significance

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Eun Sun [Chung-Ang University Hospital, Department of Radiology, Seoul (Korea, Republic of); Chung-Ang University, College of Medicine and Graduate School of Medicine, Seoul (Korea, Republic of); National Cancer Centre, Department of Radiology, Goyang-si, Gyeonggi-do (Korea, Republic of); Kim, Min Ju; Hur, Bo Yun [National Cancer Centre, Department of Radiology, Goyang-si, Gyeonggi-do (Korea, Republic of); Park, Sung Chan; Hyun, Jong Hee; Chang, Hee Jin; Baek, Ji Yeon; Kim, Dae Yong; Oh, Jae Hwan [National Cancer Centre, Centre for Colorectal Cancer, Goyang, Gyeonggi-do (Korea, Republic of); Kim, Sun Young [National Cancer Centre, Centre for Colorectal Cancer, Goyang, Gyeonggi-do (Korea, Republic of); University of Ulsan College of Medicine, Department of Oncology, Asan Medical Centre, Seoul (Korea, Republic of)

    2018-02-15

    We evaluated the diagnostic performance of magnetic resonance imaging (MRI) in terms of identifying extramural venous invasion (EMVI) in rectal cancer patients with preoperative chemoradiotherapy (CRT) and its prognostic significance. During 2008-2010, 200 patients underwent surgery following preoperative CRT for rectal cancer. Two radiologists independently reviewed all pre- and post-CRT MRI retrospectively. We investigated diagnostic performance of pre-CRT MR-EMVI (MR-EMVI) and post-CRT MR-EMVI (yMR-EMVI), based on pathological EMVI as the standard of reference. We assessed correlation between MRI findings and patients' prognosis, such as disease-free survival (DFS) and overall survival (OS). Additionally, subgroup analysis in MR- or yMR-EMVI-positive patients was performed to confirm the significance of the severity of EMVI in MRI on patient's prognosis. The sensitivity and specificity of yMR-EMVI were 76.19% and 79.75% (area under the curve: 0.830), respectively. In univariate analysis, yMR-EMVI was the only significant MRI factor in DFS (P = 0.027). The mean DFS for yMR-EMVI (+) patients was significantly less than for yMR-EMVI (-) patients: 57.56 months versus 72.46 months. yMR-EMVI demonstrated good diagnostic performance. yMR-EMVI was the only significant EMVI-related MRI factor that correlated with patients' DFS in univariate analysis; however, it was not significant in multivariate analysis. (orig.)

  9. Progress in diagnostics of the COMPASS tokamak.

    Czech Academy of Sciences Publication Activity Database

    Weinzettl, Vladimír; Adámek, Jiří; Berta, Miklós; Bílková, Petra; Bogár, Ondrej; Böhm, Petr; Cavalier, Jordan; Dejarnac, Renaud; Dimitrova, Miglena; Ficker, Ondřej; Fridrich, David; Grover, Ondřej; Háček, Pavel; Havlíček, Josef; Havránek, Aleš; Horáček, Jan; Hron, Martin; Imríšek, Martin; Komm, Michael; Kovařík, Karel; Krbec, Jaroslav; Markovič, Tomáš; Matveeva, Ekaterina; Mitošinková, Klára; Mlynář, Jan; Naydenkova, Diana; Pánek, Radomír; Papřok, Richard; Peterka, Matěj; Podolník, Aleš; Seidl, Jakub; Šos, Miroslav; Stöckel, Jan; Tomeš, Matěj; Varavin, Mykyta; Varju, Jozef; Vlainic, Milos; Vondráček, Petr; Zajac, Jaromír; Žáček, František; Stano, M.; Anda, G.; Dunai, D.; Krizsanóczi, T.; Refy, D.; Zoletnik, S.; Silva, A.; Gomes, R.; Pereira, T.; Popov, Tsv.; Sarychev, D.; Ermak, G.P.; Zebrowski, J.; Jakubowski, M.; Rabinski, M.; Malinowski, K.; Nanobashvili, S.; Spolaore, M.; Vianello, N.; Gauthier, E.; Gunn, J. P.; Devitre, A.

    2017-01-01

    Roč. 12, December (2017), č. článku C12015. ISSN 1748-0221. [European Conference on Plasma Diagnostics (ECPD2017)/2./. Bordeaux, 18.04.2017-21.04.2017] R&D Projects: GA MŠk(CZ) LM2015045; GA ČR(CZ) GA15-10723S; GA ČR(CZ) GA16-25074S; GA ČR(CZ) GA14-35260S Institutional support: RVO:61389021 Keywords : Detector design and construction technologies and materials * Nuclear instruments and methods for hot plasma diagnostics * Plasma diagnostics - interferometry,spectroscopy and imaging * Plasma diagnostics - probes Subject RIV: BL - Plasma and Gas Discharge Physics OBOR OECD: 2.11 Other engineering and technologies Impact factor: 1.220, year: 2016 http://iopscience.iop.org/article/10.1088/1748-0221/12/12/C12015/pdf

  10. Diagnostic Performance and Confidence of Contrast-Enhanced Ultrasound in the Differential Diagnosis of Cystic and Cysticlike Liver Lesions.

    Science.gov (United States)

    Corvino, Antonio; Catalano, Orlando; Corvino, Fabio; Sandomenico, Fabio; Petrillo, Antonella

    2017-09-01

    The aims of this study were to assess the diagnostic performance of contrast-enhanced ultrasound (CEUS) in the characterization of atypical cystic and cysticlike focal liver lesions in comparison with conventional US and to determine whether the use of CEUS can reduce the need for further diagnostic workup. In a 3-year period 48 patients with 50 atypical cystic and cysticlike lesions found at conventional US underwent CEUS. Diagnostic confirmation was obtained in cytohistopathologic examinations, with other imaging modalities, and in follow-up. Overall, there were 24 cystic lesions and 26 cysticlike solid lesions, specifically 32 benign and 18 malignant lesions. The conventional US and CEUS images and cine loops were reviewed by two blinded readers independently. Sensitivity, specificity, area under the ROC curve (A z ), and interobserver agreement were calculated. Diagnostic performance improved after review of CEUS examinations by both readers (conventional US A z = 0.781 vs 0.972; CEUS A z = 0.734 vs 0.957). Interreader agreement increased, although slightly (conventional US weighted κ = 0.894; CEUS weighted κ = 0.953). In terms of differential diagnosis, the occurrence of correctly characterized lesions increased after CEUS for both readers (reader 1, 62% to 98%; reader 2, 56% to 96%). The development of low-acoustic-power CEUS has made it possible to identify several imaging features of cystic and cysticlike focal liver lesions that, in association with history and clinical findings, may help to correctly characterize them. Our data indicate the usefulness of CEUS in the evaluation of patients with these lesions.

  11. Performance, diagnostics, controls and plans for the gyrotron system on the DIII-D tokamak

    Directory of Open Access Journals (Sweden)

    Ponce D.M.

    2012-09-01

    Full Text Available The DIII-D ECH complex is being upgraded with three new depressed collector gyrotrons. The performance of the existing system has been very good. As more gyrotrons having higher power are added to the system, diagnostics of gyrotron operation, optimization of the performance and qualification of components for higher power become more important. A new FPGA-based gyrotron control system is being installed, additional capabilities for rapid real time variation of the rf injection angles by the DIII-D Plasma Control System are being tested and infrastructure enhancements are being completed. Longer term plans continue to include ECH as a major component in the DIII-D heating and current drive capabilities.

  12. Plasma diagnostics package. Volume 2: Spacelab 2 section. Part B: Thesis projects. Final science report

    International Nuclear Information System (INIS)

    Pickett, J.S.; Frank, L.A.; Kurth, W.S.

    1988-06-01

    This volume (2), which consists of two parts (A and B), of the Plasma Diagnostics Package (PDP) Final Science Report contains a summary of all of the data reduction and scientific analyses which were performed using PDP data obtained on STS-51F as a part of the Spacelab 2 (SL-2) payload. This work was performed during the period of launch, July 29, 1985, through June 30, 1988. During this period the primary data reduction effort consisted of processing summary plots of the data received by 12 of the 14 instruments located on the PDP and submitting these data to the National Space Science Data Center (NSSDC). Three Master's and three Ph.D. theses were written using PDP instrumentation data. These theses are listed in Volume 2, Part B

  13. Comprehensive MR Urography Protocol: Equally Good Diagnostic Performance and Enhanced Visibility of the Upper Urinary Tract Compared to Triple-Phase CT Urography.

    Directory of Open Access Journals (Sweden)

    Mazen Sudah

    Full Text Available To prospectively compare the diagnostic performance and the visualization of the upper urinary tract (UUT using a comprehensive 3.0T- magnetic resonance urography (MRU protocol versus triple-phase computed tomography urography (CTU.During the study period (January-2014 through December-2015, all consecutive patients in our tertiary university hospital scheduled by a urologist for CTU to exclude UUT malignancy were invited to participate. Diagnostic performance and visualization scores of 3.0T-MRU were compared to CTU using Wilcoxon matched-pairs test.Twenty patients (39 UUT excreting units were evaluated. 3.0T-MRU and CTU achieved equal diagnostic performances. The benign etiology of seven UUT obstructions was clarified equally with both methods. Another two urinary tract malignant tumors and one benign extraurinary tumor were detected and confirmed. Diagnostic visualization was slightly better in the intrarenal cavity areas with CTU but worsened towards distal ureter. MRU showed consistently slightly better visualization of the ureter. In the comparison, full 100% visualizations were detected in all areas in 93.6% (with 3.0T-MRU and 87.2% (with CTU and >75% visualization in 100% (3.0T-MRU and 93.6% (CTU. Mean CTU effective radiation dose was 9.2 mSv.Comprehensive 3.0T-MRU is an accurate imaging modality achieving comparable performance with CTU; since it does not entail exposure to radiation, it has the potential to become the primary investigation technique in selected patients.ClinicalTrials.gov NCT02606513.

  14. Ultrafast Laser Diagnostics for Energetic-Material Ignition Mechanisms: Tools for Physics-Based Model Development.

    Energy Technology Data Exchange (ETDEWEB)

    Kearney, Sean Patrick; Jilek, Brook Anton; Kohl, Ian Thomas; Farrow, Darcie; Urayama, Junji

    2014-11-01

    We present the results of an LDRD project to develop diagnostics to perform fundamental measurements of material properties during shock compression of condensed phase materials at micron spatial scales and picosecond time scales. The report is structured into three main chapters, which each focus on a different diagnostic devel opment effort. Direct picosecond laser drive is used to introduce shock waves into thin films of energetic and inert materials. The resulting laser - driven shock properties are probed via Ultrafast Time Domain Interferometry (UTDI), which can additionally be used to generate shock Hugoniot data in tabletop experiments. Stimulated Raman scattering (SRS) is developed as a temperature diagnostic. A transient absorption spectroscopy setup has been developed to probe shock - induced changes during shock compressio n. UTDI results are presented under dynamic, direct - laser - drive conditions and shock Hugoniots are estimated for inert polystyrene samples and for the explosive hexanitroazobenzene, with results from both Sandia and Lawrence Livermore presented here. SRS a nd transient absorption diagnostics are demonstrated on static thin - film samples, and paths forward to dynamic experiments are presented.

  15. Diagnostic accuracy of 201Tl SPECT·MRI in brain diseases and inter-reader variance of diagnostic performance

    International Nuclear Information System (INIS)

    Machida, Kikuo; Honda, Norinari; Matsumoto, Toru

    1996-01-01

    Fifteen-four studies of 201 Tl brain tumor SPECT were independently interpreted by 9 nuclear medicine physicians with and without reference magnetic resonance images in 2 separate sessions to define an effect of referring images, and inter-observer variations. The physicians were requested to detect foci of abnormal deposits, and to discriminate whether they were malignant or not according to 5-grade scaling of subjective diagnostic confidence. Receiver-operating characteristics (ROC) analysis was performed. Mean sensitivity for presence of lesions (SFP), and sensitivity and specificity for malignancy of 2 01 Tl SPECT were 84, and 53 and 55%, which were changed to 94 and 74 and 55% after referring to the MR images. The SFP was significantly improved (p 201 Tl brain tumor SPECT has moderate sensitivity and specificity for malignancy, which is not improved by addition of anatomical reference images, that additional MR images reduce inter-observer variation of confidence on lesion presence, and that SPECT localization of lesions has great inter-observer variations. (author)

  16. Patient dosimetry and image quality in conventional diagnostic radiology. An experience from a local Serbian hospital

    International Nuclear Information System (INIS)

    Olivera Ciraj-Bjelac; Milojko Kovacevic; Dusko Kosutic; Milan Loncar; Dajana Veljkovic

    2007-01-01

    Complete test of publication follows. The optimization of image quality vs. patient dose ins an important task in medical imaging. Maximal validity of optimization has to be based on clinical images. Simultaneous measurement of patient dose levels and image quality assessment is used to investigate possibilities for dose reduction and maintain image quality. The survey was conducted in a local hospital performing more than 60000 images annually and representing typical Serbian practice. For four most frequent diagnostic procedures (seven projections) patient exposure was measured using kerma area product meter. Image quality was assessed by experienced radiologists using 'European Guidelines on Quality Criteria for Diagnostic Radiographic Images'. Following examination types were included into the survey: chest PA, chest LAT, pelvis AP, lumbar spine AP, lumbar spine LAT and LSJ, skull PA and skull LAT. Comparing actual radiographic technique with recommended technique in European Guidelines, modification of practice was proposed and implemented and image quality was re-assessed. At least 10 adult patients were followed for each projection, before and after corrective actions. Large dose saving without compromising diagnostic information were found for some examination types, showing that this simple method is very efficient dose reduction tool in conventional diagnostic radiology. Also, need for staff training and difficulties related to practical implementation of optimization methods in Serbia were discussed.

  17. Hedonic value and crowdfunding project performance: a propensity score matching-based analysis

    NARCIS (Netherlands)

    Zhao, L.; Vinig, T.

    2017-01-01

    Purpose In the existing literature on crowdfunding project performance, previous studies have given little attention to the impact of investors’ hedonic value and utilitarian value on project results. In a crowdfunding setting, utilitarian value is somehow hard to satisfy due to information

  18. Enhancement and creation of secondary channel habitat: Review of project performance across a range of project types and settings

    Science.gov (United States)

    Epstein, J.; Lind, P.

    2017-12-01

    Secondary channels provide critical off-channel habitat for key life stages of aquatic species. In many systems, interruption of natural processes via anthropogenic influences have reduced the quantity of secondary channel habitat and have impaired the processes that help form and maintain them. Creation and enhancement of secondary channels is therefore a key component of stream rehabilitation, particularly in the Pacific Northwest where the focus has been on enhancement of habitat for ESA-listed salmonids. Secondary channel enhancement varies widely in scope, scale, and approach depending on species requirements, hydrology/hydraulics, geomorphologic setting, sediment dynamics, and human constraints. This presentation will review case studies from numerous secondary channel projects constructed over the last 20 years by different entities and in different settings. Lessons learned will be discussed that help to understand project performance and inform future project design. A variety of secondary channel project types will be reviewed, including mainstem flow splits, year-round flow through, seasonally activated, backwater alcove, natural groundwater-fed, and engineered groundwater-fed (i.e. groundwater collection galleries). Projects will be discussed that span a range of project construction intensities, such as full excavation of side channels, select excavation to increase flow, or utilizing mainstem structures to activate channels. Different configurations for connecting to the main channel, and their relative performance, will also be presented. A variety of connection types will be discussed including stabilized channel entrance, free-formed entrance, using bar apex jams to split flows, using `bleeder' jams to limit secondary channel flow, and obstructing the main channel to divert flows into secondary channels. The performance and longevity of projects will be discussed, particularly with respect to the response to sediment mobilizing events. Lessons

  19. River Protection Project waste feed delivery program technical performance measurement assessment plan

    International Nuclear Information System (INIS)

    O'TOOLE, S.M.

    1999-01-01

    This plan establishes a formal technical performance-monitoring program. Technical performance is assessed by establishing requirements based performance goals at the beginning of a program and routinely evaluating progress in meeting these goals at predetermined milestones throughout the project life cycle

  20. Development of X-ray tracer diagnostics for radiatively-driven ablator experiments

    International Nuclear Information System (INIS)

    MacFarlane, J.J.; Cohen, D.H.; Wang, P.; Moses, G.A.; Peterson, R.R.; Jaanimagi, P.A.; Langen, O.L.; Olson, R.E.; Murphy, T.J.; Magelssen, G.R.; Delamater, N.D.

    1999-01-01

    This report covers fiscal year 1998 of our ongoing project to develop tracer X-ray spectroscopic diagnostics for hohlraum environments. This effort focused on an experimental campaign carried out at OMEGA on 25--27 August 1998. This phase of the project heavily emphasized experimental design, diagnostic development, and target fabrication, as well as building up numerical models for the experiments. The spectral diagnostic under development involves using two thin (few 1000 Angstroem) mid-Z tracers in two witness plates mounted on the side of a hohlraum with the tracers' K a absorption features seen against an X-ray backlighter. The absorption data are used to sample the time-dependent, localized properties of each witness plate as a radiation wave ablates it. The experiments represented the first application of this diagnostic, in this case to side-by-side doped and undoped plastic to investigate the effects of capsule ablator dopants

  1. Performance Projections For The Lithium Tokamak Experiment (LTX)

    International Nuclear Information System (INIS)

    Majeski, R.L.; Berzak, T.; Gray, R.; Kaita, T.; Kozub, F.; Levinton, D.P.; Lundberg, J.; Manickam, G.V.; Pereverzev, K.; Snieckus, V.; Soukhanovskii, J.; Spaleta, D.; Stotler, T.; Strickler, J.; Timberlake, J.; Zakharov, L.; Zakharov, Y.

    2009-01-01

    Use of a large-area liquid lithium limiter in the CDX-U tokamak produced the largest relative increase (an enhancement factor of 5-10) in Ohmic tokamak confinement ever observed. The confinement results from CDX-U do not agree with existing scaling laws, and cannot easily be projected to the new lithium tokamak experiment (LTX). Numerical simulations of CDX-U low recycling discharges have now been performed with the ASTRA-ESC code with a special reference transport model suitable for a diffusion-based confinement regime, incorporating boundary conditions for nonrecycling walls, with fueling via edge gas puffing. This model has been successful at reproducing the experimental values of the energy confinement (4-6 ms), loop voltage (<0.5 V), and density for a typical CDX-U lithium discharge. The same transport model has also been used to project the performance of the LTX, in Ohmic operation, or with modest neutral beam injection (NBI). NBI in LTX, with a low recycling wall of liquid lithium, is predicted to result in core electron and ion temperatures of 1-2 keV, and energy confinement times in excess of 50 ms. Finally, the unique design features of LTX are summarized

  2. A preliminary investigation on the effects of characteristics and contractual behaviour on civil engineering project performance

    Science.gov (United States)

    Ismail, W. N. W.; Adnan, H.; Yusuwan, N.; Maisham, M.; Hassan, A. A.

    2018-02-01

    The significant role of civil engineering project is not only to make the lives of people easier and secure but also to trigger the economic growth by providing infrastructure facilities as well as job opportunities. As it is dominantly initiated by government sectors, performance of the civil engineering projects is always observed. This study aims to investigate the characteristics of civil engineering project and the contractual behavior of the key participants and how do these two factors affect civil engineering projects performance. Literature reviews, content analysis and questionnaires survey were conducted to undertake the research. A total of 50 questionnaires were distributed and 10 questionnaires were returned, resulting in a 20% response rate. The research unveiled that performance of civil engineering projects are influenced greatly by the ability to handle the unpredictable character of the civil engineering projects and adequate behavioral management. Apart from that, balancing the factors with high quality of workmanship, avoidance or well managed conflicts and high satisfaction level will ensure performance in projects.

  3. Effects of disease severity distribution on the performance of quantitative diagnostic methods and proposal of a novel 'V-plot' methodology to display accuracy values.

    Science.gov (United States)

    Petraco, Ricardo; Dehbi, Hakim-Moulay; Howard, James P; Shun-Shin, Matthew J; Sen, Sayan; Nijjer, Sukhjinder S; Mayet, Jamil; Davies, Justin E; Francis, Darrel P

    2018-01-01

    Diagnostic accuracy is widely accepted by researchers and clinicians as an optimal expression of a test's performance. The aim of this study was to evaluate the effects of disease severity distribution on values of diagnostic accuracy as well as propose a sample-independent methodology to calculate and display accuracy of diagnostic tests. We evaluated the diagnostic relationship between two hypothetical methods to measure serum cholesterol (Chol rapid and Chol gold ) by generating samples with statistical software and (1) keeping the numerical relationship between methods unchanged and (2) changing the distribution of cholesterol values. Metrics of categorical agreement were calculated (accuracy, sensitivity and specificity). Finally, a novel methodology to display and calculate accuracy values was presented (the V-plot of accuracies). No single value of diagnostic accuracy can be used to describe the relationship between tests, as accuracy is a metric heavily affected by the underlying sample distribution. Our novel proposed methodology, the V-plot of accuracies, can be used as a sample-independent measure of a test performance against a reference gold standard.

  4. CT imaging of congenital lung lesions: effect of iterative reconstruction on diagnostic performance and radiation dose

    International Nuclear Information System (INIS)

    Haggerty, Jay E.; Smith, Ethan A.; Dillman, Jonathan R.; Kunisaki, Shaun M.

    2015-01-01

    Different iterative reconstruction techniques are available for use in pediatric computed tomography (CT), but these techniques have not been systematically evaluated in infants. To determine the effect of iterative reconstruction on diagnostic performance, image quality and radiation dose in infants undergoing CT evaluation for congenital lung lesions. A retrospective review of contrast-enhanced chest CT in infants (<1 year) with congenital lung lesions was performed. CT examinations were reviewed to document the type of lung lesion, vascular anatomy, image noise measurements and image reconstruction method. CTDI vol was used to calculate size-specific dose estimates (SSDE). CT findings were correlated with intraoperative and histopathological findings. Analysis of variance and the Student's t-test were used to compare image noise measurements and radiation dose estimates between groups. Fifteen CT examinations used filtered back projection (FBP; mean age: 84 days), 15 used adaptive statistical iterative reconstruction (ASiR; mean age: 93 days), and 11 used model-based iterative reconstruction (MBIR; mean age: 98 days). Compared to operative findings, 13/15 (87%), 14/15 (93%) and 11/11 (100%) lesions were correctly characterized using FBP, ASiR and MBIR, respectively. Arterial anatomy was correctly identified in 12/15 (80%) using FBP, 13/15 (87%) using ASiR and 11/11 (100%) using MBIR. Image noise was less for MBIR vs. ASiR (P < 0.0001). Mean SSDE was different among groups (P = 0.003; FBP = 7.35 mGy, ASiR = 1.89 mGy, MBIR = 1.49 mGy). Congenital lung lesions can be adequately characterized in infants using iterative CT reconstruction techniques while maintaining image quality and lowering radiation dose. (orig.)

  5. CT imaging of congenital lung lesions: effect of iterative reconstruction on diagnostic performance and radiation dose

    Energy Technology Data Exchange (ETDEWEB)

    Haggerty, Jay E.; Smith, Ethan A.; Dillman, Jonathan R. [University of Michigan Health System, Section of Pediatric Radiology, Department of Radiology, C.S. Mott Children' s Hospital, Ann Arbor, MI (United States); Kunisaki, Shaun M. [University of Michigan Health System, Section of Pediatric Surgery, Department of Surgery, C.S. Mott Children' s Hospital, Ann Arbor, MI (United States)

    2015-07-15

    Different iterative reconstruction techniques are available for use in pediatric computed tomography (CT), but these techniques have not been systematically evaluated in infants. To determine the effect of iterative reconstruction on diagnostic performance, image quality and radiation dose in infants undergoing CT evaluation for congenital lung lesions. A retrospective review of contrast-enhanced chest CT in infants (<1 year) with congenital lung lesions was performed. CT examinations were reviewed to document the type of lung lesion, vascular anatomy, image noise measurements and image reconstruction method. CTDI{sub vol} was used to calculate size-specific dose estimates (SSDE). CT findings were correlated with intraoperative and histopathological findings. Analysis of variance and the Student's t-test were used to compare image noise measurements and radiation dose estimates between groups. Fifteen CT examinations used filtered back projection (FBP; mean age: 84 days), 15 used adaptive statistical iterative reconstruction (ASiR; mean age: 93 days), and 11 used model-based iterative reconstruction (MBIR; mean age: 98 days). Compared to operative findings, 13/15 (87%), 14/15 (93%) and 11/11 (100%) lesions were correctly characterized using FBP, ASiR and MBIR, respectively. Arterial anatomy was correctly identified in 12/15 (80%) using FBP, 13/15 (87%) using ASiR and 11/11 (100%) using MBIR. Image noise was less for MBIR vs. ASiR (P < 0.0001). Mean SSDE was different among groups (P = 0.003; FBP = 7.35 mGy, ASiR = 1.89 mGy, MBIR = 1.49 mGy). Congenital lung lesions can be adequately characterized in infants using iterative CT reconstruction techniques while maintaining image quality and lowering radiation dose. (orig.)

  6. Assessing construction project performance in Ghana : modelling practitioners' and clients perspectives

    NARCIS (Netherlands)

    Gyadu-Asiedu, W.

    2009-01-01

    Several countries at various levels of socio-economic development have recognised the need and importance of taking measures to improve the performance of their construction industry. One of the means to this end has been to ensure performance efficiency in construction project execution. As has

  7. Man against machine: diagnostic performance of a deep learning convolutional neural network for dermoscopic melanoma recognition in comparison to 58 dermatologists.

    Science.gov (United States)

    Haenssle, H A; Fink, C; Schneiderbauer, R; Toberer, F; Buhl, T; Blum, A; Kalloo, A; Hassen, A Ben Hadj; Thomas, L; Enk, A; Uhlmann, L

    2018-05-28

    Deep learning convolutional neural networks (CNN) may facilitate melanoma detection, but data comparing a CNN's diagnostic performance to larger groups of dermatologists are lacking. Google's Inception v4 CNN architecture was trained and validated using dermoscopic images and corresponding diagnoses. In a comparative cross-sectional reader study a 100-image test-set was used (level-I: dermoscopy only; level-II: dermoscopy plus clinical information and images). Main outcome measures were sensitivity, specificity and area under the curve (AUC) of receiver operating characteristics (ROC) for diagnostic classification (dichotomous) of lesions by the CNN versus an international group of 58 dermatologists during level-I or -II of the reader study. Secondary end points included the dermatologists' diagnostic performance in their management decisions and differences in the diagnostic performance of dermatologists during level-I and -II of the reader study. Additionally, the CNN's performance was compared with the top-five algorithms of the 2016 International Symposium on Biomedical Imaging (ISBI) challenge. In level-I dermatologists achieved a mean (±standard deviation) sensitivity and specificity for lesion classification of 86.6% (±9.3%) and 71.3% (±11.2%), respectively. More clinical information (level-II) improved the sensitivity to 88.9% (±9.6%, P = 0.19) and specificity to 75.7% (±11.7%, P < 0.05). The CNN ROC curve revealed a higher specificity of 82.5% when compared with dermatologists in level-I (71.3%, P < 0.01) and level-II (75.7%, P < 0.01) at their sensitivities of 86.6% and 88.9%, respectively. The CNN ROC AUC was greater than the mean ROC area of dermatologists (0.86 versus 0.79, P < 0.01). The CNN scored results close to the top three algorithms of the ISBI 2016 challenge. For the first time we compared a CNN's diagnostic performance with a large international group of 58 dermatologists, including 30 experts. Most dermatologists

  8. A Meta-analysis for the Diagnostic Performance of Transient Elastography for Clinically Significant Portal Hypertension.

    Science.gov (United States)

    You, Myung-Won; Kim, Kyung Won; Pyo, Junhee; Huh, Jimi; Kim, Hyoung Jung; Lee, So Jung; Park, Seong Ho

    2017-01-01

    We aimed to evaluate the correlation between liver stiffness measurement using transient elastography (TE-LSM) and hepatic venous pressure gradient and the diagnostic performance of TE-LSM in assessing clinically significant portal hypertension through meta-analysis. Eleven studies were included from thorough literature research and selection processes. The summary correlation coefficient was 0.783 (95% confidence interval [CI], 0.737-0.823). Summary sensitivity, specificity and area under the hierarchical summary receiver operating characteristic curve (AUC) were 87.5% (95% CI, 75.8-93.9%), 85.3 % (95% CI, 76.9-90.9%) and 0.9, respectively. The subgroup with low cut-off values of 13.6-18 kPa had better summary estimates (sensitivity 91.2%, specificity 81.3% and partial AUC 0.921) than the subgroup with high cut-off values of 21-25 kPa (sensitivity 71.2%, specificity 90.9% and partial AUC 0.769). In summary, TE-LSM correlated well with hepatic venous pressure gradient and represented good diagnostic performance in diagnosing clinically significant portal hypertension. For use as a sensitive screening tool, we propose using low cut-off values of 13.6-18 kPa in TE-LSM. Copyright © 2016 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.

  9. Thermal performance advisor expert system development

    International Nuclear Information System (INIS)

    McClintock, M.; Hirota, N.; Metzinger, R.

    1991-01-01

    In recent years the electric industry has developed an increased interest in improving efficiency of nuclear power plants. EPRI has embarked upon a research project RP2407, Nuclear Plant Performance Improvements which is designed to address needs in this area. One product of this project has been the Thermal Performance Diagnostic Manual for Nuclear Power Plants (NP-4990P). The purpose of this manual is to provide engineering personnel at nuclear power plants with a consistent way in which to identify thermal performance problems. General Physics is also involved in the development of another computer system called Fossil Thermal Performance Advisor (FTPA) which helps operators improve performance for fossil power plants. FTPA is a joint venture between General Physics and New York State Electric and Gas Company. This paper describes both of these computer systems and uses the FTPA as an interesting comparison that illustrates the considerations required for the development of a computer system that effectively addresses the needs of the users

  10. Diagnostic methods for insect sting allergy.

    Science.gov (United States)

    Hamilton, Robert G

    2004-08-01

    This review overviews advances from mid-2002 to the present in the validation and performance methods used in the diagnosis of Hymenoptera venom-induced immediate-type hypersensitivity. The general diagnostic algorithm for insect sting allergy is initially discussed with an examination of the AAAAI's 2003 revised practice parameter guidelines. Changes as a result of a greater recognition of skin test negative systemic reactors include repeat analysis of all testing and acceptance of serology as a complementary diagnostic test to the skin test. Original data examining concordance of venom-specific IgE results produced by the second-generation Pharmacia CAP System with the Johns Hopkins University radioallergosorbent test are presented. Diagnostic performance of honeybee venom-specific IgE assays used in clinical laboratories in North America is discussed using data from the Diagnostic Allergy Proficiency Survey conducted by the College of American Pathologists. Validity of venom-specific IgE antibody in postmortem blood specimens is demonstrated. The utility of alternative in-vivo (provocation) and in-vitro (basophil-based) diagnostic testing methods is critiqued. This overview supports the following conclusions. Improved practice parameter guidelines include serology and skin test as complementary in supporting a positive clinical history during the diagnostic process. Data are provided which support the analytical performance of commercially available venom-specific IgE antibody serology-based assays. Intentional sting challenge in-vivo provocation, in-vitro basophil flow cytometry (CD63, CD203c) based assays, and in-vitro basophil histamine and sulfidoleukotriene release assays have their utility in the study of difficult diagnostic cases, but their use will remain as supplementary, secondary diagnostic tests.

  11. Diagnostic devices for osteoporosis in the general population

    DEFF Research Database (Denmark)

    Høiberg, M P; Rubin, Katrine Hass; Hermann, Pernille

    2016-01-01

    INTRODUCTION: A diagnostic gap exists in the current dual photon X-ray absorptiometry (DXA) based diagnostic approach to osteoporosis. Other diagnostic devices have been developed, but no comprehensive review concerning the applicability of these diagnostic devices for population-based screening...... have been performed. MATERIAL AND METHODS: A systematic review of Embase, Medline and the Cochrane Central Register for Controlled Trials was performed for population-based studies that focused on technical methods that could either indicate bone mineral density (BMD) by DXA, substitute for DXA...

  12. Plasma Diagnostics

    Energy Technology Data Exchange (ETDEWEB)

    Zaveryaev, V [Kurchatov Institute, Moscow (Russian Federation); others, and

    2012-09-15

    The success in achieving peaceful fusion power depends on the ability to control a high temperature plasma, which is an object with unique properties, possibly the most complicated object created by humans. Over years of fusion research a new branch of science has been created, namely plasma diagnostics, which involves knowledge of almost all fields of physics, from electromagnetism to nuclear physics, and up-to-date progress in engineering and technology (materials, electronics, mathematical methods of data treatment). Historically, work on controlled fusion started with pulsed systems and accordingly the methods of plasma parameter measurement were first developed for short lived and dense plasmas. Magnetically confined hot plasmas require the creation of special experimental techniques for diagnostics. The diagnostic set is the most scientifically intensive part of a plasma device. During many years of research operation some scientific tasks have been solved while new ones arose. New tasks often require significant changes in the diagnostic system, which is thus a very flexible part of plasma machines. Diagnostic systems are designed to solve several tasks. As an example here are the diagnostic tasks for the International Thermonuclear Experimental Reactor - ITER: (1) Measurements for machine protection and basic control; (2) Measurements for advanced control; (3) Additional measurements for performance evaluation and physics. Every new plasma machine is a further step along the path to the main goal - controlled fusion - and nobody knows in advance what new phenomena will be met on the way. So in the planning of diagnostic construction we should keep in mind further system upgrading to meet possible new scientific and technical challenges. (author)

  13. Development of a Diagnostic Complexity Questionnaire

    International Nuclear Information System (INIS)

    Collier, Steve

    1998-02-01

    The HRP human error analysis project has for some time been investigating what makes certain fault scenarios difficult for operators. One line of research has been to develop a questionnaire to measure diagnostic complexity. This report concerns some theoretical and experimental work underpinning the development of the questionnaire. A study of the literature reviewed the factors or components thought to contribute to difficulty in diagnosing and problem-solving. Two experimental studies of complexity were carried out using two versions of a questionnaire based on the review. The studies were simulator based, using scenarios designed to be diagnostically challenging. A factor-analytic approach to the analysis of the study data was suggested in the literature review. This is reported here (together with other analyses) though the factor analysis did not produce so clear results as was hoped. The present analysis found no clear factor structure with the first version of the complexity questionnaire used in experiment I. Partly because of this result, a factor-analytic approach to a second version of the questionnaire used in experiment II was not considered appropriate. A descriptive and qualitative analysis of the two questionnaire studies and a synthesis of the results from them both was promising. There were indications of components of complexity and some indications of what contributes to a personal perception of high or low diagnostic difficulty in fault scenarios. Components adding to diagnostic difficulty were tentatively named 'severity', 'need for co-operation', 'stress' and 'spread of changes'. Components not adding to difficulty were 'directness of indications', 'familiarity' and 'lack of stress'. There was some evidence of different responses to these components in a comparison of rule-based vs. knowledge-based diagnostic scenarios. These findings and experience with analysis techniques will feed into the design of further work on the human error

  14. ITER diagnostics: Design choices and solutions

    International Nuclear Information System (INIS)

    Costley, A.E.; Sugie, T.; Vayakis, G.; Malaquias, A.; Walker, C.

    2003-01-01

    An extensive diagnostic system will be installed on ITER to provide the measurements necessary to control, evaluate and optimise the plasma performance and to study burning plasma physics. Because of the harsh environment, diagnostic system selection and design has to cope with a range of phenomena not previously encountered in diagnostic implementation. In this paper, we describe the key problems encountered and give examples of the solutions that have been developed. A brief description of the scheme developed for integrating multiple systems into individual ports is also included. We conclude with an assessment of overall system performance. (author)

  15. Principal elements of the Basalt Waste Isolation Project performance assessment studies

    International Nuclear Information System (INIS)

    Baca, R.G.; Wilde, R.T.

    1983-12-01

    In this paper, three of the principal elements of the Basalt Waste Isolation Project (BWIP) performance assessment studies are focused on: (1) development of a methodology for probabilistic risk assessment, (2) performance analyses of repository subsystems, and (3) selection and ranking of disruptive event scenarios. Other elements of the BWIP performance assessment studies are briefly outlined. 12 references, 5 figures

  16. Development of GEM detector for plasma diagnostics application: simulations addressing optimization of its performance

    Science.gov (United States)

    Chernyshova, M.; Malinowski, K.; Kowalska-Strzęciwilk, E.; Czarski, T.; Linczuk, P.; Wojeński, A.; Krawczyk, R. D.

    2017-12-01

    The advanced Soft X-ray (SXR) diagnostics setup devoted to studies of the SXR plasma emissivity is at the moment a highly relevant and important for ITER/DEMO application. Especially focusing on the energy range of tungsten emission lines, as plasma contamination by W and its transport in the plasma must be understood and monitored for W plasma-facing material. The Gas Electron Multiplier, with a spatial and energy-resolved photon detecting chamber, based SXR radiation detection system under development by our group may become such a diagnostic setup considering and solving many physical, technical and technological aspects. This work presents the results of simulations aimed to optimize a design of the detector's internal chamber and its performance. The study of the effect of electrodes alignment allowed choosing the gap distances which maximizes electron transmission and choosing the optimal magnitudes of the applied electric fields. Finally, the optimal readout structure design was identified suitable to collect a total formed charge effectively, basing on the range of the simulated electron cloud at the readout plane which was in the order of ~ 2 mm.

  17. Team building and diagnostic training

    International Nuclear Information System (INIS)

    Bulmer, S.

    1987-01-01

    While developing a commercial training program to improve teamwork in control room crews, General Electric's Nuclear Training Services made an important discovery. Traditional training methods for developing teamwork and enhancing diagnostics capabilities are incomplete. Traditional methods generally help, but fail to fulfill the long-term needs of most teams. Teamwork has been treated as a short-term performance problem. Traditional diagnostic training suffers from a similar problem. Too often, it covers only the basic principles of decision-making, ignoring the development of expert diagnostic capabilities. In response to this discovery, they have developed comprehensive training in Team Building and Diagnostics

  18. The Use of the Performance Diagnostic Checklist-Human Services to Assess and Improve the Job Performance of Individuals with Intellectual Disabilities.

    Science.gov (United States)

    Smith, Madison; Wilder, David A

    2018-06-01

    The Performance Diagnostic Checklist-Human Services (PDC-HS) is an informant-based tool designed to identify the variables responsible for performance problems. To date, the PDC-HS has not been examined with individuals with intellectual disabilities. In the current study, two supervisors with intellectual disabilities completed the PDC-HS to assess the productivity of two supervisees with disabilities who performed a pricing task in a thrift store. The PDC-HS suggested that performance deficits were due to a lack of training; a PDC-HS-indicated intervention was effective to increase accurate pricing. • The PDC-HS is an informant-based tool designed to identify the variables responsible for employee performance problems in human service settings. • The PDC-HS can be completed by some individuals with intellectual disabilities in a supervisory position to identify the variables responsible for problematic job performance among their supervisees. • A PDC-HS indicated intervention was demonstrated to be effective to improve the job performance of individuals with disabilities. • The PDC-HS may be a useful tool to support performance improvement and job maintenance among individuals with intellectual disabilities.

  19. ’Point of Injury’ Sampling Technology for Battlefield Molecular Diagnostics

    Science.gov (United States)

    2012-03-17

    Injury" Sampling Technology for Battlefield Molecular Diagnostics March 17,2012 Sponsored by Defense Advanced Research Projects Agency (DOD) Defense...Contract: April 25, 2011 Short Title of Work: "Point of Injury" Sampling Technology for Battlefield Molecular Diagnostics " Contract Expiration Date...SBIR PHASE I OPTION REPORT: Point of Injury, Sampling Technology for Battlefield Molecular Diagnostics . W31P4Q-1 l-C-0222 (UNCLASSIFIED) P.I

  20. Using technology-enhanced, cooperative, group-project learning for student comprehension and academic performance

    Science.gov (United States)

    Tlhoaele, Malefyane; Suhre, Cor; Hofman, Adriaan

    2016-05-01

    Cooperative learning may improve students' motivation, understanding of course concepts, and academic performance. This study therefore enhanced a cooperative, group-project learning technique with technology resources to determine whether doing so improved students' deep learning and performance. A sample of 118 engineering students, randomly divided into two groups, participated in this study and provided data through questionnaires issued before and after the experiment. The results, obtained through analyses of variance and structural equation modelling, reveal that technology-enhanced, cooperative, group-project learning improves students' comprehension and academic performance.

  1. LIFAC sorbent injection desulfurization demonstration project. Final report, volume II: Project performance and economics

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1996-01-01

    This publication discusses the demonstration of the LIFAC sorbent injection technology at Richmond Power and Light`s Whitewater Valley Unit No. 2, performed under the auspices of the U.S. Department of Energy`s (DOE) Clean Coal Technology Program. LIFAC is a sorbent injection technology capable of removing 75 to 85 percent of a power plant`s SO{sub 2} emissions using limestone at calcium to sulfur molar ratios of between 2 and 2.5 to 1. The site of the demonstration is a coal-fired electric utility power plant located in Richmond, Indiana. The project is being conducted by LIFAC North America (LIFAC NA), a joint venture partnership of Tampella Power Corporation and ICF Kaiser Engineers, in cooperation with DOE, RP&L, and Research Institute (EPRI), the State of Indiana, and Black Beauty Coal Company. The purpose of Public Design Report Volume 2: Project Performance and Economics is to consolidate, for public use, the technical efficiency and economy of the LIFAC Process. The report has been prepared pursuant to the Cooperative Agreement No. DE-FC22-90PC90548 between LIFAC NA and the U.S. Department of Energy.

  2. Tomosynthesis for the early detection of pulmonary emphysema: diagnostic performance compared with chest radiography, using multidetector computed tomography as reference

    International Nuclear Information System (INIS)

    Yamada, Yoshitake; Jinzaki, Masahiro; Hashimoto, Masahiro; Shiomi, Eisuke; Kuribayashi, Sachio; Abe, Takayuki; Ogawa, Kenji

    2013-01-01

    To compare the diagnostic performance of tomosynthesis with that of chest radiography for the detection of pulmonary emphysema, using multidetector computed tomography (MDCT) as reference. Forty-eight patients with and 63 without pulmonary emphysema underwent chest MDCT, tomosynthesis and radiography on the same day. Two blinded radiologists independently evaluated the tomosynthesis images and radiographs for the presence of pulmonary emphysema. Axial and coronal MDCT images served as the reference standard and the percentage lung volume with attenuation values of -950 HU or lower (LAA -950 ) was evaluated to determine the extent of emphysema. Receiver-operating characteristic (ROC) analysis and generalised estimating equations model were used. ROC analysis revealed significantly better performance (P -950 . The diagnostic performance of tomosynthesis was significantly superior to that of radiography for the detection of pulmonary emphysema. In both tomosynthesis and radiography, the sensitivity was affected by the LAA -950 . (orig.)

  3. Long-Term Evaluation of SSL Field Performance in Select Interior Projects

    Energy Technology Data Exchange (ETDEWEB)

    Perrin, Tess E. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Davis, Robert G. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Wilkerson, Andrea M. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States)

    2017-02-28

    This GATEWAY project evaluated four field installations to better understand the long-term performance of a number of LED products, which can hopefully stimulate improvements in designing, manufacturing, specifying, procuring, and installing LED products. Field studies provide the opportunity to discover and investigate issues that cannot be simulated or uncovered in a laboratory, but the installed performance over time of commercially available LED products has not been well documented. Improving long-term performance can provide both direct energy savings by reducing the need to over-light to account for light loss and indirect energy savings through better market penetration due to SSL’s competitive advantages over less-efficient light source technologies. The projects evaluated for this report illustrate that SSL use is often motivated by advantages other than energy savings, including maintenance savings, easier integration with control systems, and improved lighting quality.

  4. Center of Cancer Nanotechnology Excellence for Translational Diagnostics

    Science.gov (United States)

    The Center of Cancer Nanotechnology Excellence for Translational Diagnostics, which forms the third cycle CCNE Program at Stanford University, is a consortium that has three highly synchronized Projects and three Cores.

  5. Diagnostic performance of magnetic resonance imaging and pre-surgical evaluation in the assessment of traumatic intra-articular knee disorders in children and adolescents: what conditions still pose diagnostic challenges?

    Energy Technology Data Exchange (ETDEWEB)

    Gans, Itai; Ganley, Theodore J. [The Children' s Hospital of Philadelphia, Division of Orthopaedics, 34th and Civic Center Boulevard, Philadelphia, PA (United States); Bedoya, Maria A.; Ho-Fung, Victor [The Children' s Hospital of Philadelphia, Department of Radiology, Philadelphia, PA (United States)

    2014-08-31

    Diagnosis of intra-articular lesions in children based on clinical examination and MRI is particularly challenging. To evaluate the diagnostic performance of MRI and pre-surgical evaluation of the knee in pediatric patients relative to arthroscopic evaluation as the gold standard. We report diagnoses frequently missed or inaccurately diagnosed pre-operatively. We conducted a retrospective review of MRI and pre-surgical evaluation in children and adolescents ages 1-17 years who were treated by knee arthroscopy during a 21/2-year period. All MRIs were reviewed by a pediatric radiologist blinded to clinical findings. Pediatric orthopedic clinic notes were reviewed for pre-surgical evaluation (based on physical exam, radiograph, MR images and radiologist's MRI report). Arthroscopic findings were used as the gold standard. We calculated the percentages of diagnoses at arthroscopy missed on both MRI and pre-surgical evaluation. Diagnostic accuracy between children and adolescents and in patients with one pathological lesion vs. those with >1 lesion was analyzed. We performed a second review of MR images of the missed or over-called MRI diagnoses with knowledge of arthroscopic findings. We included 178 children and adolescents. The most common diagnoses missed on MRI or pre-surgical evaluation but found at arthroscopy were: discoid meniscus (8/30, or 26.7% of cases); lateral meniscal tears (15/80, or 18.8% of cases); intra-articular loose bodies (5/36, or 13.9% of cases), and osteochondral injuries (9/73, or 12.3% of cases). Overall diagnostic accuracy of MRI and pre-surgical evaluation was 92.7% and 95.3%, respectively. No significant difference in diagnostic accuracy between children and adolescents was observed. When multiple intra-articular lesions were present, lateral meniscal tears were more likely to be inaccurately diagnosed (missed or over-called) on both MRI (P = 0.009) and pre-surgical evaluation (P < 0.001). Overall diagnostic accuracy of MRI and pre

  6. Diagnostic performance of magnetic resonance imaging and pre-surgical evaluation in the assessment of traumatic intra-articular knee disorders in children and adolescents: what conditions still pose diagnostic challenges?

    International Nuclear Information System (INIS)

    Gans, Itai; Ganley, Theodore J.; Bedoya, Maria A.; Ho-Fung, Victor

    2015-01-01

    Diagnosis of intra-articular lesions in children based on clinical examination and MRI is particularly challenging. To evaluate the diagnostic performance of MRI and pre-surgical evaluation of the knee in pediatric patients relative to arthroscopic evaluation as the gold standard. We report diagnoses frequently missed or inaccurately diagnosed pre-operatively. We conducted a retrospective review of MRI and pre-surgical evaluation in children and adolescents ages 1-17 years who were treated by knee arthroscopy during a 21/2-year period. All MRIs were reviewed by a pediatric radiologist blinded to clinical findings. Pediatric orthopedic clinic notes were reviewed for pre-surgical evaluation (based on physical exam, radiograph, MR images and radiologist's MRI report). Arthroscopic findings were used as the gold standard. We calculated the percentages of diagnoses at arthroscopy missed on both MRI and pre-surgical evaluation. Diagnostic accuracy between children and adolescents and in patients with one pathological lesion vs. those with >1 lesion was analyzed. We performed a second review of MR images of the missed or over-called MRI diagnoses with knowledge of arthroscopic findings. We included 178 children and adolescents. The most common diagnoses missed on MRI or pre-surgical evaluation but found at arthroscopy were: discoid meniscus (8/30, or 26.7% of cases); lateral meniscal tears (15/80, or 18.8% of cases); intra-articular loose bodies (5/36, or 13.9% of cases), and osteochondral injuries (9/73, or 12.3% of cases). Overall diagnostic accuracy of MRI and pre-surgical evaluation was 92.7% and 95.3%, respectively. No significant difference in diagnostic accuracy between children and adolescents was observed. When multiple intra-articular lesions were present, lateral meniscal tears were more likely to be inaccurately diagnosed (missed or over-called) on both MRI (P = 0.009) and pre-surgical evaluation (P < 0.001). Overall diagnostic accuracy of MRI and pre

  7. Measures to Improve Diagnostic Safety in Clinical Practice.

    Science.gov (United States)

    Singh, Hardeep; Graber, Mark L; Hofer, Timothy P

    2016-10-20

    Timely and accurate diagnosis is foundational to good clinical practice and an essential first step to achieving optimal patient outcomes. However, a recent Institute of Medicine report concluded that most of us will experience at least one diagnostic error in our lifetime. The report argues for efforts to improve the reliability of the diagnostic process through better measurement of diagnostic performance. The diagnostic process is a dynamic team-based activity that involves uncertainty, plays out over time, and requires effective communication and collaboration among multiple clinicians, diagnostic services, and the patient. Thus, it poses special challenges for measurement. In this paper, we discuss how the need to develop measures to improve diagnostic performance could move forward at a time when the scientific foundation needed to inform measurement is still evolving. We highlight challenges and opportunities for developing potential measures of "diagnostic safety" related to clinical diagnostic errors and associated preventable diagnostic harm. In doing so, we propose a starter set of measurement concepts for initial consideration that seem reasonably related to diagnostic safety and call for these to be studied and further refined. This would enable safe diagnosis to become an organizational priority and facilitate quality improvement. Health-care systems should consider measurement and evaluation of diagnostic performance as essential to timely and accurate diagnosis and to the reduction of preventable diagnostic harm.This is an open-access article distributed under the terms of the Creative Commons Attribution-Non Commercial-No Derivatives License 4.0 (CCBY-NC-ND), where it is permissible to download and share the work provided it is properly cited. The work cannot be changed in any way or used commercially without permission from the journal.

  8. Validation of the fifth edition BI-RADS ultrasound lexicon with comparison of fourth and fifth edition diagnostic performance using video clips

    International Nuclear Information System (INIS)

    Yoon, Jung Hyun; Kim, Min Jung; Lee, Hye Sun; Kim, Sung Hun; Youk, Ji Hyun; Jeong, Sun Hye; Kim, You Me

    2016-01-01

    The aim of this study was to evaluate the positive predictive value (PPV) and the diagnostic performance of the ultrasonographic descriptors in the fifth edition of BI-RADS, comparing with the fourth edition using video clips. From September 2013 to July 2014, 80 breast masses in 74 women (mean age, 47.5±10.7 years) from five institutions of the Korean Society of Breast Imaging were included. Two radiologists individually reviewed the static and video images and analyzed the images according to the fourth and fifth edition of BI-RADS. The PPV of each descriptor was calculated and diagnostic performances between the fourth and fifth editions were compared. Of the 80 breast masses, 51 (63.8%) were benign and 29 (36.2%) were malignant. Suspicious ultrasonographic features such as irregular shape, non-parallel orientation, angular or spiculated margins, and combined posterior features showed higher PPV in both editions (all P<0.05). No significant differences were found in the diagnostic performances between the two editions (all P>0.05). The area under the receiver operating characteristics curve was higher in the fourth edition (0.708 to 0.690), without significance (P=0.416). The fifth edition of the BI-RADS ultrasound lexicon showed comparable performance to the fourth edition and can be useful in the differential diagnosis of breast masses using ultrasonography

  9. Systems Performance Analyses of Alaska Wind-Diesel Projects; Kotzebue, Alaska (Fact Sheet)

    Energy Technology Data Exchange (ETDEWEB)

    Baring-Gould, I.

    2009-04-01

    This fact sheet summarizes a systems performance analysis of the wind-diesel project in Kotzebue, Alaska. Data provided for this project include wind turbine output, average wind speed, average net capacity factor, and optimal net capacity factor based on Alaska Energy Authority wind data, estimated fuel savings, and wind system availability.

  10. The SUCCESS model for laboratory performance and execution of rapid molecular diagnostics in patients with sepsis.

    Science.gov (United States)

    Dekmezian, Mhair; Beal, Stacy G; Damashek, Mary Jane; Benavides, Raul; Dhiman, Neelam

    2015-04-01

    Successful performance and execution of rapid diagnostics in a clinical laboratory hinges heavily on careful validation, accurate and timely communication of results, and real-time quality monitoring. Laboratories must develop strategies to integrate diagnostics with stewardship and evidence-based clinical practice guidelines. We present a collaborative SUCCESS model for execution and monitoring of rapid sepsis diagnostics to facilitate timely treatment. Six months after execution of the Verigene Gram-Positive Blood Culture (BC-GP) and the AdvanDx PNA-FISH assays, data were collected on 579 and 28 episodes of bacteremia and fungemia, respectively. Clinical testing was executed using a SUCCESS model comprising the following components: stewardship, utilization of resources, core strategies, concierge services, education, support, and surveillance. Stewardship needs were identified by evaluating the specialty services benefiting from new testing. Utilization of resources was optimized by reviewing current treatment strategies and antibiogram and formulary options. Core strategies consisted of input from infectious disease leadership, pharmacy, and laboratory staff. Concierge services included automated Micro-eUpdate and physician-friendly actionable reports. Education modules were user-specific, and support was provided through a dedicated 24/7 microbiology hotline. Surveillance was performed by daily audit by the director. Using the SUCCESS model, the turnaround time for the detailed report with actionable guidelines to the physician was ∼3 hours from the time of culture positivity. The overall correlation between rapid methods and culture was 94% (546/579). Discrepant results were predominantly contaminants such as a coagulase-negative staphylococci or viridans streptococci in mixed cultures. SUCCESS is a cost-effective and easily adaptable model for clinical laboratories with limited stewardship resources.

  11. Evaluation of lymph node status after neoadjuvant chemotherapy in breast cancer patients: comparison of diagnostic performance of ultrasound, MRI and ¹⁸F-FDG PET/CT.

    Science.gov (United States)

    You, S; Kang, D K; Jung, Y S; An, Y-S; Jeon, G S; Kim, T H

    2015-08-01

    To evaluate the diagnostic performance of ultrasound, MRI and fluorine-18 fludeoxyglucose positron emission tomography (¹⁸F-FDG PET)/CT for the diagnosis of metastatic axillary lymph node (ALN) after neoadjuvant chemotherapy (NAC) and to find out histopathological factors affecting the diagnostic performance of these imaging modalities. From January 2012 to November 2014, 191 consecutive patients with breast cancer who underwent NAC before surgery were retrospectively reviewed. We included 139 patients with ALN metastasis that was confirmed on fine needle aspiration or core needle biopsy at initial diagnosis. After NAC, 39 (28%) patients showed negative conversion of ALN on surgical specimens of sentinel lymph node (LN) or ALN. The sensitivity of ultrasound, MRI and PET/CT was 50% (48/96), 72% (70/97) and 22% (16/73), respectively. The specificity of ultrasound, MRI and PET/CT was 77% (30/39), 54% (21/39) and 85% (22/26), respectively. The Az value of combination of ultrasound and PET/CT was the highest (0.634) followed by ultrasound (0.626) and combination of ultrasound, MRI and PET/CT (0.617). The size of tumour deposit in LN and oestrogen receptor was significantly associated with the diagnostic performance of ultrasound (p performance of PET/CT (p = 0.023, p = 0.002, p = 0.036, p = 0.044 and p = 0.008, respectively). On multivariate logistic regression analysis, size of tumour deposit within LN was identified as being independently associated with diagnostic performance of ultrasound [odds ratio, 13.07; 95% confidence interval (CI), 2.95-57.96] and PET/CT (odds ratio, 6.47; 95% CI, 1.407-29.737). Combination of three imaging modalities showed the highest sensitivity, and PET/CT showed the highest specificity for the evaluation of ALN metastasis after NAC. Ultrasound alone or combination of ultrasound and PET/CT showed the highest positive-predictive value. The size of tumour deposit within ALN was significantly associated with

  12. Diagnostic imaging of exotic pets

    International Nuclear Information System (INIS)

    Silverman, S.

    1993-01-01

    Radiographic, ultrasonographic, and computed tomographic (CT) imaging are important diagnostic modalities in exotic pets. The use of appropriate radiographic equipment, film-screen combinations, and radiographic projections enhances the information obtained from radiographs. Both normal findings and common radiographic abnormalities are discussed. The use of ultrasonography and CT scanning for exotic small mammals and reptiles is described

  13. Crohn's Disease Evaluated with Magnetic Resonance Enteroclysis: Diagnostic Performance of Experienced and Inexperienced Readers before and after Training

    International Nuclear Information System (INIS)

    Negaard, A.; Mulahasanovic, A.; Reisaeter, L.A.; Aasekjaer, K.; Sandvik, L.; Klow, N.E.

    2008-01-01

    Background: Magnetic resonance enteroclysis (MRE) is suggested to become the preferred radiological method in small-bowel Crohn's disease (CD). However, the performance of inexperienced readers may influence the diagnostic value of the method and has not been previously investigated. Purpose: To compare readings of MRE in small-bowel CD performed by experienced and inexperienced readers before and after training.Material and Methods: One experienced radiologist (observer 1) and two trainees (observers 2 and 3) reviewed 60 MRE examinations. A second reading was performed after training. Bowel wall thickness (BWT), ulcers (BWU), stenosis (BWS), fistulas (FIS), and abscesses (ABS) were evaluated. A reference standard based on clinical records was established. Results: BWT in the terminal ileum was evaluated with high diagnostic performance (sensitivity: observer 1, 83%; observer 2, 72%; observer 3, 78%). Only BWU was diagnosed with a higher sensitivity by observer 1 (78% vs. 33% and 39%, respectively; P=0.02). False-positive findings for BWT in the jejunum (observer 2: 7; observer 3: 4) and fistulas and abscesses (observer 2: 11/5; observer 3: 5/4) were made by the trainees. Interobserver agreement in the jejunum was poor (observer 1/observer 2: κ=0.23; observer 1/observer 3: κ=-0.03) and in the ileum good (observer 1/observer 2: κ=0.78; observer 1/observer 3: κ=0.73). After training, evaluation of BWU (observer 2: 56%, P=0.22; observer 3: 44%, P=0.03), BWT (observer 2: 2; observer 3: 2), and interobserver agreement in the jejunum improved (observer 1/observer 2: κ=0.66; observer 1/observer 3: κ=0.66). However, the number of diagnosed fistulas and abscesses remained high. Conclusion: Before training, most findings of Crohn's disease in the terminal ileum were evaluated with high diagnostic performance by all readers. However, the inexperienced readers evaluated BWU with a low sensitivity and overestimated the number of FIS, number of ABS, and increased BWT in

  14. Using Project Performance to Measure Effectiveness of Quality Management System Maintenance and Practices in Construction Industry

    Science.gov (United States)

    Leong, Tiong Kung; Ariff, Mohd. Shoki Md.

    2014-01-01

    This paper proposed seven existing and new performance indicators to measure the effectiveness of quality management system (QMS) maintenance and practices in construction industry. This research is carried out with a questionnaire based on QMS variables which are extracted from literature review and project performance indicators which are established from project management's theory. Data collected was analyzed using correlation and regression analysis. The findings indicate that client satisfaction and time variance have positive and significant relationship with QMS while other project performance indicators do not show significant results. Further studies can use the same project performance indicators to study the effectiveness of QMS in different sampling area to improve the generalizability of the findings. PMID:24701182

  15. Using Project Performance to Measure Effectiveness of Quality Management System Maintenance and Practices in Construction Industry

    Directory of Open Access Journals (Sweden)

    Tiong Kung Leong

    2014-01-01

    Full Text Available This paper proposed seven existing and new performance indicators to measure the effectiveness of quality management system (QMS maintenance and practices in construction industry. This research is carried out with a questionnaire based on QMS variables which are extracted from literature review and project performance indicators which are established from project management's theory. Data collected was analyzed using correlation and regression analysis. The findings indicate that client satisfaction and time variance have positive and significant relationship with QMS while other project performance indicators do not show significant results. Further studies can use the same project performance indicators to study the effectiveness of QMS in different sampling area to improve the generalizability of the findings.

  16. Using project performance to measure effectiveness of quality management system maintenance and practices in construction industry.

    Science.gov (United States)

    Leong, Tiong Kung; Zakuan, Norhayati; Mat Saman, Muhamad Zameri; Ariff, Mohd Shoki Md; Tan, Choy Soon

    2014-01-01

    This paper proposed seven existing and new performance indicators to measure the effectiveness of quality management system (QMS) maintenance and practices in construction industry. This research is carried out with a questionnaire based on QMS variables which are extracted from literature review and project performance indicators which are established from project management's theory. Data collected was analyzed using correlation and regression analysis. The findings indicate that client satisfaction and time variance have positive and significant relationship with QMS while other project performance indicators do not show significant results. Further studies can use the same project performance indicators to study the effectiveness of QMS in different sampling area to improve the generalizability of the findings.

  17. Diagnostic performance of CT-arthrography and 1.5T MR-arthrography for the assessment of glenohumeral joint cartilage: a comparative study with arthroscopic correlation

    Energy Technology Data Exchange (ETDEWEB)

    Omoumi, Patrick [Cliniques Universitaires St Luc - Universite Catholique de Louvain, Department of Radiology, Brussels (Belgium); Lausanne University Hospital, Department of Radiology, Lausanne (Switzerland); Rubini, Alexandra; Berg, Bruno C. vande; Lecouvet, Frederic E. [Cliniques Universitaires St Luc - Universite Catholique de Louvain, Department of Radiology, Brussels (Belgium); Dubuc, Jean-Emile [Cliniques Universitaires St Luc - Universite Catholique de Louvain, Department of Orthopedic Surgery, Brussels (Belgium)

    2015-04-01

    To compare the diagnostic performance of multi-detector CT arthrography (CTA) and 1.5-T MR arthrography (MRA) in detecting hyaline cartilage lesions of the shoulder, with arthroscopic correlation. CTA and MRA prospectively obtained in 56 consecutive patients following the same arthrographic procedure were independently evaluated for glenohumeral cartilage lesions (modified Outerbridge grade ≥2 and grade 4) by two musculoskeletal radiologists. The cartilage surface was divided in 18 anatomical areas. Arthroscopy was taken as the reference standard. Diagnostic performance of CTA and MRA was compared using ROC analysis. Interobserver and intraobserver agreement was determined by κ statistics. Sensitivity and specificity of CTA varied from 46.4 to 82.4 % and from 89.0 to 95.9 % respectively; sensitivity and specificity of MRA varied from 31.9 to 66.2 % and from 91.1 to 97.5 % respectively. Diagnostic performance of CTA was statistically significantly better than MRA for both readers (all p ≤ 0.04). Interobserver agreement for the evaluation of cartilage lesions was substantial with CTA (κ = 0.63) and moderate with MRA (κ = 0.54). Intraobserver agreement was almost perfect with both CTA (κ = 0.94-0.95) and MRA (κ = 0.83-0.87). The diagnostic performance of CTA and MRA for the detection of glenohumeral cartilage lesions is moderate, although statistically significantly better with CTA. (orig.)

  18. Adaptive statistical iterative reconstruction and Veo: assessment of image quality and diagnostic performance in CT colonography at various radiation doses.

    Science.gov (United States)

    Yoon, Min A; Kim, Se Hyung; Lee, Jeong Min; Woo, Hyoun Sik; Lee, Eun Sun; Ahn, Se Jin; Han, Joon Koo

    2012-01-01

    To evaluate the diagnostic performance of computed tomography (CT) colonography (CTC) reconstructed with different levels of adaptive statistical iterative reconstruction (ASiR, GE Healthcare) and Veo (model-based iterative reconstruction, GE Healthcare) at various tube currents in detection of polyps in porcine colon phantoms. Five porcine colon phantoms with 46 simulated polyps were scanned at different radiation doses (10, 30, and 50 mA s) and were reconstructed using filtered back projection (FBP), ASiR (20%, 40%, and 60%) and Veo. Eleven data sets for each phantom (10-mA s FBP, 10-mA s 20% ASiR, 10-mA s 40% ASiR, 10-mA s 60% ASiR, 10-mA s Veo, 30-mA s FBP, 30-mA s 20% ASiR, 30-mA s 40% ASiR, 30-mA s 60% ASiR, 30-mA s Veo, and 50-mA s FBP) yielded a total of 55 data sets. Polyp detection sensitivity and confidence level of 2 independent observers were evaluated with the McNemar test, the Fisher exact test, and receiver operating characteristic curve analysis. Comparative analyses of overall image quality score, measured image noise, and interpretation time were also performed. Per-polyp detection sensitivities and specificities were highest in 10-mA s Veo, 30-mA s FBP, 30-mA s 60% ASiR, and 50-mA s FBP (sensitivity, 100%; specificity, 100%). The area-under-the-curve values for the overall performance of each data set was also highest (1.000) at 50-mA s FBP, 30-mA s FBP, 30-mA s 60% ASiR, and 10-mA s Veo. Images reconstructed with ASiR showed statistically significant improvement in per-polyp detection sensitivity as the percent level of per-polyp sensitivity increased (10-mA s FBP vs 10-mA s 20% ASiR, P = 0.011; 10-mA s FBP vs 10-mA s 40% ASiR, P = 0.000; 10-mA s FBP vs 10-mA s 60% ASiR, P = 0.000; 10-mA s 20% ASiR vs 40% ASiR, P = 0.034). Overall image quality score was highest at 30-mA s Veo and 50-mA s FBP. The quantitative measurement of the image noise was lowest at 30-mA s Veo and second lowest at 10-mA s Veo. There was a trend of decrease in time

  19. Effects of disease severity distribution on the performance of quantitative diagnostic methods and proposal of a novel ‘V-plot’ methodology to display accuracy values

    Science.gov (United States)

    Dehbi, Hakim-Moulay; Howard, James P; Shun-Shin, Matthew J; Sen, Sayan; Nijjer, Sukhjinder S; Mayet, Jamil; Davies, Justin E; Francis, Darrel P

    2018-01-01

    Background Diagnostic accuracy is widely accepted by researchers and clinicians as an optimal expression of a test’s performance. The aim of this study was to evaluate the effects of disease severity distribution on values of diagnostic accuracy as well as propose a sample-independent methodology to calculate and display accuracy of diagnostic tests. Methods and findings We evaluated the diagnostic relationship between two hypothetical methods to measure serum cholesterol (Cholrapid and Cholgold) by generating samples with statistical software and (1) keeping the numerical relationship between methods unchanged and (2) changing the distribution of cholesterol values. Metrics of categorical agreement were calculated (accuracy, sensitivity and specificity). Finally, a novel methodology to display and calculate accuracy values was presented (the V-plot of accuracies). Conclusion No single value of diagnostic accuracy can be used to describe the relationship between tests, as accuracy is a metric heavily affected by the underlying sample distribution. Our novel proposed methodology, the V-plot of accuracies, can be used as a sample-independent measure of a test performance against a reference gold standard. PMID:29387424

  20. Energy Utilization Evaluation of Carbon Performance in Public Projects by FAHP and Cloud Model

    Directory of Open Access Journals (Sweden)

    Lin Li

    2016-07-01

    Full Text Available With the low-carbon economy advocated all over the world, how to use energy reasonably and efficiently in public projects has become a major issue. It has brought many open questions, including which method is more reasonable in evaluating the energy utilization of carbon performance in public projects when the evaluation information is fuzzy; whether an indicator system can be constructed; and which indicators have more impact on carbon performance. This article aims to solve these problems. We propose a new carbon performance evaluation system for energy utilization based on project processes (design, construction, and operation. Fuzzy Analytic Hierarchy Process (FAHP is used to accumulate the indicator weights and cloud model is incorporated when the indicator value is fuzzy. Finally, we apply our indicator system to a case study of the Xiangjiang River project in China, which demonstrates the applicability and efficiency of our method.

  1. Comparison of diagnostic performance between single- and multiphasic contrast-enhanced abdominopelvic computed tomography in patients admitted to the emergency department with abdominal pain: potential radiation dose reduction.

    Science.gov (United States)

    Hwang, Shin Hye; You, Je Sung; Song, Mi Kyong; Choi, Jin-Young; Kim, Myeong-Jin; Chung, Yong Eun

    2015-04-01

    To evaluate feasibility of radiation dose reduction by optimal phase selection of computed tomography (CT) in patients who visited the emergency department (ED) for abdominal pain. We included 253 patients who visited the ED for abdominal pain. They underwent multiphasic CT including precontrast, late arterial phase (LAP), and hepatic venous phase (HVP). Three image sets (HVP, precontrast + HVP, and precontrast + LAP + HVP) were reviewed. Two reviewers determined the most appropriate diagnosis with five-point confidence scale. Diagnostic performances were compared among image sets by weighted-least-squares method or DeLong's method. Linear mixed model was used to assess changes of diagnostic confidence and radiation dose. There was no difference in diagnostic performance among three image sets, although diagnostic confidence level was significantly improved after review of triphasic images compared with both HVP images only or HVP with precontrast images (confidence scale, 4.64 ± 0.05, 4.66 ± 0.05, and 4.76 ± 0.04 in the order of the sets; overall P = 0.0008). Similar trends were observed in the subgroup analysis for diagnosis of pelvic inflammatory disease and cholecystitis. There is no difference between HVP-CT alone and multiphasic CT for the diagnosis of causes of abdominal pain in patients admitted to the ED without prior chronic disease or neoplasia. • There was no difference in diagnostic performance of HVP CT and multiphasic CT. • The diagnostic confidence level was improved after review of the LAP images. • HVP CT can achieve diagnostic performance similar to that of multiphasic CT, while minimizing radiation.

  2. Diagnostic Performance of Narrow Band Imaging for Nasopharyngeal Cancer: A Systematic Review and Meta-analysis.

    Science.gov (United States)

    Sun, Changling; Zhang, Yayun; Han, Xue; Du, Xiaodong

    2018-03-01

    Objective The purposes of this study were to verify the effectiveness of the narrow band imaging (NBI) system in diagnosing nasopharyngeal cancer (NPC) as compared with white light endoscopy. Data Sources PubMed, Cochrane Library, EMBASE, CNKI, and Wan Fang databases. Review Methods Data analyses were performed with Meta-Disc. The updated Quality Assessment of Diagnostic Accuracy Studies-2 tool was used to assess study quality and potential bias. Publication bias was assessed with a Deeks asymmetry test. The registry number of the protocol published on PROSPERO is CRD42015026244. Results This meta-analysis included 10 studies of 1337 lesions. For NBI diagnosis of NPC, the pooled values were as follows: sensitivity, 0.83 (95% CI, 0.80-0.86); specificity, 0.91 (95% CI, 0.89-0.93); positive likelihood ratio, 8.82 (95% CI, 5.12-15.21); negative likelihood ratio, 0.18 (95% CI, 0.12-0.27); and diagnostic odds ratio, 65.73 (95% CI, 36.74-117.60). The area under the curve was 0.9549. For white light endoscopy in diagnosing NPC, the pooled values were as follows: sensitivity, 0.79 (95% CI, 0.75-0.83); specificity, 0.87 (95% CI, 0.84-0.90); positive likelihood ratio, 5.02 (95% CI, 1.99-12.65); negative likelihood ratio, 0.34 (95% CI, 0.24-0.49); and diagnostic odds ratio, 16.89 (95% CI, 5.98-47.66). The area under the curve was 0.8627. The evaluation of heterogeneity, calculated per the diagnostic odds ratio, gave an I 2 of 0.326. No marked publication bias ( P = .68) existed in this meta-analysis. Conclusion The sensitivity and specificity of NBI for the diagnosis of NPC are similar to those of white light endoscopy, and the potential value of NBI for the diagnosis of NPC needs to be validated further.

  3. Glaucoma diagnostic performance of GDxVCC and spectralis OCT on eyes with atypical retardation pattern.

    Science.gov (United States)

    Hoesl, Laura Maria; Tornow, Ralf P; Schrems, Wolfgang A; Horn, Folkert K; Mardin, Christian Y; Kruse, Friedrich E; Juenemann, Anselm G M; Laemmer, Robert

    2013-01-01

    To investigate the impact of typical scan score (TSS) on discriminating glaucomatous and healthy eyes by scanning laser polarimetry and spectral domain optical coherence tomography (SD-OCT) in 32 peripapillary sectors. One hundred two glaucoma patients and 32 healthy controls underwent standard automated perimetry, 24-hour intraocular pressure profile, optic disc photography, GDxVCC, and SD-OCT measurements. For controls, only very typical scans (TSS=100) were accepted. Glaucoma patients were divided into 3 subgroups (very typical: TSS=100; typical: 99≥TSS≥80, atypical: TSS<80). Receiver operating characteristic curves were constructed for mean retinal nerve fiber layer values, sector data, and nerve fiber indicator (NFI). Sensitivity was estimated at ≥90% specificity to compare the discriminating ability of each imaging modality. For discrimination between healthy and glaucomatous eyes with very typical scans, the NFI and inferior sector analyses 26 to 27 demonstrated the highest sensitivity at ≥90% specificity in GDxVCC and SD-OCT, respectively. For the typical and atypical groups, sensitivity at ≥90% specificity decreased for all 32 peripapillary sectors on an average by 10.9% and 17.9% for GDxVCC and by 4.9% and 0.8% for SD-OCT. For GDxVCC, diagnostic performance of peripapillary sectors decreased with lower TSS, especially in temporosuperior and inferotemporal sectors (sensitivity at ≥90% specificity decreased by 55.3% and by 37.8% in the atypical group). Diagnostic accuracy is comparable for SD-OCT and GDxVCC if typical scans (TSS=100) are investigated. Decreasing TSS is associated with a decrease in diagnostic accuracy for discriminating healthy and glaucomatous eyes by scanning laser polarimetry. NFI is less influenced than the global or sector retinal nerve fiber layer thickness. The TSS score should be included in the standard printout. Diagnostic accuracy of SD-OCT is barely influenced by low TSS.

  4. Target diagnostic system for the National Ignition Facility (NIF)

    International Nuclear Information System (INIS)

    Leeper, R.J.; Chandler, G.A.; Cooper, G.W.; Derzon, M.S.

    1996-01-01

    A review of recent progress on the design of a diagnostic system proposed for ignition target experiments on the National Ignition Facility (NIF) will be presented. This diagnostic package contains an extensive suite of optical, x-ray, gamma-ray, and neutron diagnostics that enable measurements of the performance of both direct and indirect driven NIF targets. The philosophy used in designing all of the diagnostics in the set has emphasized redundant and independent measurement of fundamental physical quantities relevant to the operation of the NIF target. A unique feature of these diagnostics is that they are being designed to be capable of operating, in the high radiation, EMP, and debris backgrounds expected on the NIF facility. The diagnostic system proposed can be categorized into three broad areas: laser characterization, hohlraum characterization, and capsule performance diagnostics. The operating principles of a representative instrument from each class of diagnostic employed in this package will be summarized and illustrated with data obtained in recent prototype diagnostic tests

  5. Evaluation of Diagnostic Tests Using Information Theory for Multi-Class Diagnostic Problems and its Application for the Detection of Occlusal Caries Lesions

    Directory of Open Access Journals (Sweden)

    Umut Arslan

    2014-09-01

    Full Text Available Background: Several methods are available to evaluate the performance of the tests when the purpose of the diagnostic test is to discriminate between two possible disease states. However multi-class diagnostic problems frequently appear in many areas of medical science. Hence, there is a need for methods which will enable us to characterize the accuracy of diagnostic tests when there are more than two possible disease states. Aims: To show that two information theory measures, information content (IC and proportional reduction in diagnostic uncertainty (PRDU, can be used for the evaluation of the performance of diagnostic tests for multi-class diagnostic problems that may appear in different areas of medical science. Study Design: Diagnostic accuracy study. Methods: Sixty freshly extracted permanent human molar and premolar teeth suspected to have occlusal caries lesions were selected for the study and were assessed by two experienced examiners. Each examiner performed two evaluations. Histological examination was used as the gold standard. The scores of the histological examination were defined as sound (n=11, enamel caries (n=22 and dentin caries (n=27. Diagnostic performance of i visual inspection, ii radiography, iii laser fluorescence (LF and iv micro-computed tomography (M-CT caries detection methods was evaluated by calculating IC and PRDU. Results: Micro-computed tomography examination was the best method among the diagnostic techniques for the diagnosis of occlusal caries in terms of both IC and PRDU. M-CT examination supplied the maximum diagnostic information about the diagnosis of occlusal caries in the first (IC: 1.056; p<0.05, (PRDU: 70.5% and second evaluation (IC: 1.105; p<0.05, (PRDU: 73.8% for the first examiner. M-CT examination was the best method among the diagnostic techniques for the second examiner in both the first (IC:1.105; p<0.05, (PRDU:73.8% and second evaluation (IC:1.061; p<0.05, (PRDU:70.8%. IC and PRDU were

  6. Overview of diagnostic performance and results for the first operation phase in Wendelstein 7-X (invited).

    Science.gov (United States)

    Krychowiak, M; Adnan, A; Alonso, A; Andreeva, T; Baldzuhn, J; Barbui, T; Beurskens, M; Biel, W; Biedermann, C; Blackwell, B D; Bosch, H S; Bozhenkov, S; Brakel, R; Bräuer, T; Brotas de Carvalho, B; Burhenn, R; Buttenschön, B; Cappa, A; Cseh, G; Czarnecka, A; Dinklage, A; Drews, P; Dzikowicka, A; Effenberg, F; Endler, M; Erckmann, V; Estrada, T; Ford, O; Fornal, T; Frerichs, H; Fuchert, G; Geiger, J; Grulke, O; Harris, J H; Hartfuß, H J; Hartmann, D; Hathiramani, D; Hirsch, M; Höfel, U; Jabłoński, S; Jakubowski, M W; Kaczmarczyk, J; Klinger, T; Klose, S; Knauer, J; Kocsis, G; König, R; Kornejew, P; Krämer-Flecken, A; Krawczyk, N; Kremeyer, T; Książek, I; Kubkowska, M; Langenberg, A; Laqua, H P; Laux, M; Lazerson, S; Liang, Y; Liu, S C; Lorenz, A; Marchuk, A O; Marsen, S; Moncada, V; Naujoks, D; Neilson, H; Neubauer, O; Neuner, U; Niemann, H; Oosterbeek, J W; Otte, M; Pablant, N; Pasch, E; Sunn Pedersen, T; Pisano, F; Rahbarnia, K; Ryć, L; Schmitz, O; Schmuck, S; Schneider, W; Schröder, T; Schuhmacher, H; Schweer, B; Standley, B; Stange, T; Stephey, L; Svensson, J; Szabolics, T; Szepesi, T; Thomsen, H; Travere, J-M; Trimino Mora, H; Tsuchiya, H; Weir, G M; Wenzel, U; Werner, A; Wiegel, B; Windisch, T; Wolf, R; Wurden, G A; Zhang, D; Zimbal, A; Zoletnik, S

    2016-11-01

    Wendelstein 7-X, a superconducting optimized stellarator built in Greifswald/Germany, started its first plasmas with the last closed flux surface (LCFS) defined by 5 uncooled graphite limiters in December 2015. At the end of the 10 weeks long experimental campaign (OP1.1) more than 20 independent diagnostic systems were in operation, allowing detailed studies of many interesting plasma phenomena. For example, fast neutral gas manometers supported by video cameras (including one fast-frame camera with frame rates of tens of kHz) as well as visible cameras with different interference filters, with field of views covering all ten half-modules of the stellarator, discovered a MARFE-like radiation zone on the inboard side of machine module 4. This structure is presumably triggered by an inadvertent plasma-wall interaction in module 4 resulting in a high impurity influx that terminates some discharges by radiation cooling. The main plasma parameters achieved in OP1.1 exceeded predicted values in discharges of a length reaching 6 s. Although OP1.1 is characterized by short pulses, many of the diagnostics are already designed for quasi-steady state operation of 30 min discharges heated at 10 MW of ECRH. An overview of diagnostic performance for OP1.1 is given, including some highlights from the physics campaigns.

  7. The spin project: safety and performance indicators in different time frames

    International Nuclear Information System (INIS)

    Storck, R.; Becker, D.A.

    2002-01-01

    Safety and performance indicators have been under discussion for many years in several countries and international organisations. If those indicators refer to the long term safety of the total disposal system, they are often called safety indicators. If they refer to the performance of subsystems or the total system from a more technical point of view, they are sometimes called performance indicators. The need for indicators other than dose rates derives e.g. from the long time frames involved in safety assessments of waste disposal systems and the increasing uncertainty in dose rate calculations over time due to uncertainty in evolution of the surface environment and of behaviour of man. Before introducing additional indicators into a safety case of a potential repository site, the applicability and usefulness of different indicators have to be investigated and evaluated. The systematic analysis and testing of safety and performance indicators for use in different time horizons after closure of the disposal facility is the task of the SPIN project. This is done by re-calculating four recent studies concerning repository projects in granite formations. (authors)

  8. The influences of attributes, skills and knowledge of managers on refurbishment project performance

    Science.gov (United States)

    Ishak, Nurfadzillah

    2018-02-01

    Recently, the momentum on the growth of national building industry shows the increasing of the demand in refurbishment works becomes a trend spreading over the Malaysia. However, the potential of these activities normally related with the complexity in technical aspect compared to new build schemes. It will be reflecting on the unsatisfactory project performance. A competent manager is required to have the appropriate attributes, skills and knowledge in able to perform all the duties associated with managing the refurbishment building projects. Therefore, this paper is to identify the most appropriate attributes, skills and knowledge that required for managers to indicate the relationship between the influences on the refurbishment projects performance. This finding is indicate the importance of development the personal attributes, skills, and knowledge of managers and adds as benefit of raising the profile and image of managers in refurbishment building industry through a dissemination of the findings.

  9. Stakeholders' perception of key performance indicators (KPIs of public-private partnership (PPP projects

    Directory of Open Access Journals (Sweden)

    Olabode Emmanuel Ogunsanmi

    2013-12-01

    Full Text Available The study investigates key performance indicators (KPIs that could improve performance of public-private partnership (PPP projects in Nigeria. The study objectives include a comparison of stakeholders’ perception on KPIs and to investigate if significant difference exists between stakeholders’ perceptions on most KPIs. A structured questionnaire was used to collect information from various respondents who were recently involved in PPP projects. Random sampling technique was used to select forty-five (45 respondents out of which thirty-one (31 responses were used for the data analysis. The results indicate that top KPIs for performance improvement are levels of design complexity and technological advancement, and return on investment. Stakeholders agree on most of the rankings of the KPIs. The general perception of stakeholders was similar on most KPIs except for a few divergent opinions. The study findings have an implication for policy and decision making such that stakeholders could pay special attention to the KPIs identified, that could improve construction project performance. Finally the study recommends further research to explore KPIs for other procurement options.

  10. A Management Maturity Model (MMM for project-based organisational performance assessment

    Directory of Open Access Journals (Sweden)

    Craig Langston

    2016-12-01

    Full Text Available Common sense suggests that organisations are more likely to deliver successful projects if they have systems in place that reflect a mature project environment based on a culture of continuous improvement. This paper develops and discusses a Management Maturity Model (MMM to assess the maturity of project management organisations through a customisable, systematic, strategic and practical methodology inspired from the seminal work of Darwin, Deming, Drucker and Daniel. The model presented is relevant to organisations, such as construction and engineering companies, that prefer to use the Project Management Body of Knowledge (PMBOK™ Guide published by the Project Management Institute (PMI, but without the disadvantages of excessive time and cost commitments and a ‘one size fits all’ approach linked to rigid increments of maturity. It offers a game-changing advance in the application of project-based organisational performance assessment compared to existing market solutions that are unnecessarily complex. The feasibility of MMM is field-tested using a medium-sized data centre infrastructure firm in Tehran.

  11. Status of TMX upgrade diagnostics construction

    International Nuclear Information System (INIS)

    Hornady, R.S.; Davis, J.C.; Simonen, T.C.

    1981-01-01

    This report describes the status of the initial TMX Upgrade diagnostics and the state of development of additional diagnostics being prepared for later TMX Upgrade experiments. The initial diagnostic instrument set has been described in the TMX Upgrade Proposal. This set is required to get TMX Upgrade operational and to evaluate its initial performance. Additional diagnostic instruments are needed to then carry out the more detailed experiments outlined by the TMX Upgrade program milestones. The relation of these new measurements to the physics program is described in The TMX Upgrade Program Plan

  12. Cost/schedule performance measurement system utilized on the Fast Flux Test Facility project

    International Nuclear Information System (INIS)

    Brown, R.K.; Frost, R.A.; Zimmerman, F.M.

    1976-01-01

    An Earned Value-Integrated Cost/Schedule Performance Measurement System has been applied to a major nonmilitary nuclear design and construction project. This system is similar to the Department of Defense Cost/Schedule Performance Measurement System. The project is the Fast Flux Test Facility (a Fuels and Materials test reactor for the Liquid Metal Fast Breeder Reactor Program) being built at the Hanford Engineering Development Laboratory, Richland, Washington, by Westinghouse Hanford Company for the U. S. Energy Research and Development Administration. Because the project was well into the construction phase when the Earned Value System was being considered, it was decided that the principles of DOD's Cost/Schedule Control System Criteria would be applied to the extent possible but no major changes in accounting practices or management systems were imposed. Implementation of this system enabled the following questions to be answered: For work performed, how do actual costs compare with the budget for that work. What is the impact of cost and schedule variances at an overall project level composed of different kinds of activities. Without the Earned Value system, these questions could be answered in a qualitative, subjective manner at best

  13. Computer-Assisted Classification Patterns in Autoimmune Diagnostics: The AIDA Project

    Directory of Open Access Journals (Sweden)

    Amel Benammar Elgaaied

    2016-01-01

    Full Text Available Antinuclear antibodies (ANAs are significant biomarkers in the diagnosis of autoimmune diseases in humans, done by mean of Indirect ImmunoFluorescence (IIF method, and performed by analyzing patterns and fluorescence intensity. This paper introduces the AIDA Project (autoimmunity: diagnosis assisted by computer developed in the framework of an Italy-Tunisia cross-border cooperation and its preliminary results. A database of interpreted IIF images is being collected through the exchange of images and double reporting and a Gold Standard database, containing around 1000 double reported images, has been settled. The Gold Standard database is used for optimization of a CAD (Computer Aided Detection solution and for the assessment of its added value, in order to be applied along with an Immunologist as a second Reader in detection of autoantibodies. This CAD system is able to identify on IIF images the fluorescence intensity and the fluorescence pattern. Preliminary results show that CAD, used as second Reader, appeared to perform better than Junior Immunologists and hence may significantly improve their efficacy; compared with two Junior Immunologists, the CAD system showed higher Intensity Accuracy (85,5% versus 66,0% and 66,0%, higher Patterns Accuracy (79,3% versus 48,0% and 66,2%, and higher Mean Class Accuracy (79,4% versus 56,7% and 64.2%.

  14. Computer-Assisted Classification Patterns in Autoimmune Diagnostics: The AIDA Project.

    Science.gov (United States)

    Benammar Elgaaied, Amel; Cascio, Donato; Bruno, Salvatore; Ciaccio, Maria Cristina; Cipolla, Marco; Fauci, Alessandro; Morgante, Rossella; Taormina, Vincenzo; Gorgi, Yousr; Marrakchi Triki, Raja; Ben Ahmed, Melika; Louzir, Hechmi; Yalaoui, Sadok; Imene, Sfar; Issaoui, Yassine; Abidi, Ahmed; Ammar, Myriam; Bedhiafi, Walid; Ben Fraj, Oussama; Bouhaha, Rym; Hamdi, Khouloud; Soumaya, Koudhi; Neili, Bilel; Asma, Gati; Lucchese, Mariano; Catanzaro, Maria; Barbara, Vincenza; Brusca, Ignazio; Fregapane, Maria; Amato, Gaetano; Friscia, Giuseppe; Neila, Trai; Turkia, Souayeh; Youssra, Haouami; Rekik, Raja; Bouokez, Hayet; Vasile Simone, Maria; Fauci, Francesco; Raso, Giuseppe

    2016-01-01

    Antinuclear antibodies (ANAs) are significant biomarkers in the diagnosis of autoimmune diseases in humans, done by mean of Indirect ImmunoFluorescence (IIF) method, and performed by analyzing patterns and fluorescence intensity. This paper introduces the AIDA Project (autoimmunity: diagnosis assisted by computer) developed in the framework of an Italy-Tunisia cross-border cooperation and its preliminary results. A database of interpreted IIF images is being collected through the exchange of images and double reporting and a Gold Standard database, containing around 1000 double reported images, has been settled. The Gold Standard database is used for optimization of a CAD (Computer Aided Detection) solution and for the assessment of its added value, in order to be applied along with an Immunologist as a second Reader in detection of autoantibodies. This CAD system is able to identify on IIF images the fluorescence intensity and the fluorescence pattern. Preliminary results show that CAD, used as second Reader, appeared to perform better than Junior Immunologists and hence may significantly improve their efficacy; compared with two Junior Immunologists, the CAD system showed higher Intensity Accuracy (85,5% versus 66,0% and 66,0%), higher Patterns Accuracy (79,3% versus 48,0% and 66,2%), and higher Mean Class Accuracy (79,4% versus 56,7% and 64.2%).

  15. Computer-Assisted Classification Patterns in Autoimmune Diagnostics: The AIDA Project

    Science.gov (United States)

    Benammar Elgaaied, Amel; Cascio, Donato; Bruno, Salvatore; Ciaccio, Maria Cristina; Cipolla, Marco; Fauci, Alessandro; Morgante, Rossella; Taormina, Vincenzo; Gorgi, Yousr; Marrakchi Triki, Raja; Ben Ahmed, Melika; Louzir, Hechmi; Yalaoui, Sadok; Imene, Sfar; Issaoui, Yassine; Abidi, Ahmed; Ammar, Myriam; Bedhiafi, Walid; Ben Fraj, Oussama; Bouhaha, Rym; Hamdi, Khouloud; Soumaya, Koudhi; Neili, Bilel; Asma, Gati; Lucchese, Mariano; Catanzaro, Maria; Barbara, Vincenza; Brusca, Ignazio; Fregapane, Maria; Amato, Gaetano; Friscia, Giuseppe; Neila, Trai; Turkia, Souayeh; Youssra, Haouami; Rekik, Raja; Bouokez, Hayet; Vasile Simone, Maria; Fauci, Francesco; Raso, Giuseppe

    2016-01-01

    Antinuclear antibodies (ANAs) are significant biomarkers in the diagnosis of autoimmune diseases in humans, done by mean of Indirect ImmunoFluorescence (IIF) method, and performed by analyzing patterns and fluorescence intensity. This paper introduces the AIDA Project (autoimmunity: diagnosis assisted by computer) developed in the framework of an Italy-Tunisia cross-border cooperation and its preliminary results. A database of interpreted IIF images is being collected through the exchange of images and double reporting and a Gold Standard database, containing around 1000 double reported images, has been settled. The Gold Standard database is used for optimization of a CAD (Computer Aided Detection) solution and for the assessment of its added value, in order to be applied along with an Immunologist as a second Reader in detection of autoantibodies. This CAD system is able to identify on IIF images the fluorescence intensity and the fluorescence pattern. Preliminary results show that CAD, used as second Reader, appeared to perform better than Junior Immunologists and hence may significantly improve their efficacy; compared with two Junior Immunologists, the CAD system showed higher Intensity Accuracy (85,5% versus 66,0% and 66,0%), higher Patterns Accuracy (79,3% versus 48,0% and 66,2%), and higher Mean Class Accuracy (79,4% versus 56,7% and 64.2%). PMID:27042658

  16. Diagnostic performance of reduced-dose CT with a hybrid iterative reconstruction algorithm for the detection of hypervascular liver lesions: a phantom study

    Energy Technology Data Exchange (ETDEWEB)

    Nakamoto, Atsushi; Tanaka, Yoshikazu; Juri, Hiroshi; Nakai, Go; Narumi, Yoshifumi [Osaka Medical College, Department of Radiology, Takatsuki, Osaka (Japan); Yoshikawa, Shushi [Osaka Medical College Hospital, Central Radiology Department, Takatsuki, Osaka (Japan)

    2017-07-15

    To investigate the diagnostic performance of reduced-dose CT with a hybrid iterative reconstruction (IR) algorithm for the detection of hypervascular liver lesions. Thirty liver phantoms with or without simulated hypervascular lesions were scanned with a 320-slice CT scanner with control-dose (40 mAs) and reduced-dose (30 and 20 mAs) settings. Control-dose images were reconstructed with filtered back projection (FBP), and reduced-dose images were reconstructed with FBP and a hybrid IR algorithm. Objective image noise and the lesion to liver contrast-to-noise ratio (CNR) were evaluated quantitatively. Images were interpreted independently by 2 blinded radiologists, and jackknife alternative free-response receiver-operating characteristic (JAFROC) analysis was performed. Hybrid IR images with reduced-dose settings (both 30 and 20 mAs) yielded significantly lower objective image noise and higher CNR than control-dose FBP images (P <.05). However, hybrid IR images with reduced-dose settings had lower JAFROC1 figure of merit than control-dose FBP images, although only the difference between 20 mAs images and control-dose FBP images was significant for both readers (P <.01). An aggressive reduction of the radiation dose would impair the detectability of hypervascular liver lesions, although objective image noise and CNR would be preserved by a hybrid IR algorithm. (orig.)

  17. SNS Diagnostics

    International Nuclear Information System (INIS)

    Shea, T.J.; Cameron, P.; Doolittle, L.; Power, J.

    2000-01-01

    The Spallation Neutron Source (SNS) Project is a collaborative effort to build the next generation neutron science facility at Oak Ridge, TN. The facility will deliver a 2 MW proton beam to a liquid mercury target. Neutrons from this target will be moderated and sent to several state-of-the-art instruments. Six national laboratories are involved in SNS construction. Berkeley (LBNL) will build the front end that produces a 2.5 MeV, 52 mA H-beam. Los Alamos (LANL) is responsible for the 1 GeV linac with a superconducting section provided by Thomas Jefferson (JLab). Brookhaven (BNL) is building the transfer lines and accumulator ring. Oak Ridge (ORNL) and Argonne (ANL) have responsibility for the target and instruments. All activities are coordinated by the SNS project office at Oak Ridge. The high beam power, a desired availability of 95%, and an aggressive commissioning schedule lead to some interesting challenges in beam diagnostics

  18. Nova diagnostics summary

    International Nuclear Information System (INIS)

    Slivinsky, V.W.; Drake, R.P.

    1985-01-01

    The authors intend that Nova be the best diagnosed ICF research facility in operation today. The authors experience in providing advanced diagnostics for previous laser systems will be extended at Nova, and will be challenged by the development of new instrumentation to diagnose the more advanced targets made possible by this powerful laser. Previous experience has shown that to understand target performance, the authors must have as complete a set of diagnostics as possible. The Nova diagnostics are divided into two sets: the basic set required for the initial Nova experiments and the more advanced set for later, generally more complex, experiments. The basic set will be operational for the first Nova shots; it was a Nova line item funded with Nova construction money. This basic set is presented in a table

  19. Diagnostic performance of 3D standing CT imaging for detection of knee osteoarthritis features.

    Science.gov (United States)

    Segal, Neil A; Nevitt, Michael C; Lynch, John A; Niu, Jingbo; Torner, James C; Guermazi, Ali

    2015-07-01

    To determine the diagnostic performance of standing computerized tomography (SCT) of the knee for osteophytes and subchondral cysts compared with fixed-flexion radiography, using MRI as the reference standard. Twenty participants were recruited from the Multicenter Osteoarthritis Study. Participants' knees were imaged with SCT while standing in a knee-positioning frame, and with postero-anterior fixed-flexion radiography and 1T MRI. Medial and lateral marginal osteophytes and subchondral cysts were scored on bilateral radiographs and coronal SCT images using the OARSI grading system and on coronal MRI using Whole Organ MRI Scoring. Imaging modalities were read separately with images in random order. Sensitivity, specificity and accuracy for the detection of lesions were calculated and differences between modalities were tested using McNemar's test. Participants' mean age was 66.8 years, body mass index was 29.6 kg/m(2) and 50% were women. Of the 160 surfaces (medial and lateral femur and tibia for 40 knees), MRI revealed 84 osteophytes and 10 subchondral cysts. In comparison with osteophytes and subchondral cysts detected by MRI, SCT was significantly more sensitive (93 and 100%; p osteophytes) than plain radiographs (sensitivity 60 and 10% and accuracy 79 and 94%, respectively). For osteophytes, differences in sensitivity and accuracy were greatest at the medial femur (p = 0.002). In comparison with MRI, SCT imaging was more sensitive and accurate for detection of osteophytes and subchondral cysts than conventional fixed-flexion radiography. Additional study is warranted to assess diagnostic performance of SCT measures of joint space width, progression of OA features and the patellofemoral joint.

  20. Reflexivity in performative science shop projects

    OpenAIRE

    Beunen, R.; Duineveld, M.; During, R.; Straver, G.H.M.B.; Aalvanger, A.

    2012-01-01

    Science shop research projects offer possibilities for universities to engage with communities. Many science shop projects directly or indirectly intend to empower certain marginalised groups or interests within a decision-making process. In this article we argue that it is important to reflect on the role and position the researchers have in these projects. We present three science shop projects to illustrate some of the dilemmas that may arise in relation to citizen empowerment, democracy, ...

  1. The role of risk management in the design of diagnostics for fusion reactors

    Energy Technology Data Exchange (ETDEWEB)

    Ingesson, L. C. [Fusion for Energy, Josep Pla 2, Torres Diagonal Litoral B3, 08019 Barcelona (Spain); Collaboration: F4E Diagnostic Project Team

    2014-08-21

    A project-oriented approach is beneficial for the selection and design of viable diagnostics for fusion reactors because of the associated complex physical and organizational environment. The project-oriented approach includes rigorous risk management. The nature and impact of risks related to technical, organizational and commercial aspects in relation to the development of ITER diagnostics under EU responsibility are analyzed. The majority of risks are related to organizational aspects and technical feasibility issues. The experience with ITER is extrapolated to DEMO and beyond. It should not be taken for granted that technical solutions will be found, while a risk analysis of various diagnostic techniques with quantitative assessments undertaken early in the design of DEMO would be beneficial.

  2. Advanced Ground Systems Maintenance Physics Models For Diagnostics Project

    Science.gov (United States)

    Perotti, Jose M.

    2015-01-01

    The project will use high-fidelity physics models and simulations to simulate real-time operations of cryogenic and systems and calculate the status/health of the systems. The project enables the delivery of system health advisories to ground system operators. The capability will also be used to conduct planning and analysis of cryogenic system operations. This project will develop and implement high-fidelity physics-based modeling techniques tosimulate the real-time operation of cryogenics and other fluids systems and, when compared to thereal-time operation of the actual systems, provide assessment of their state. Physics-modelcalculated measurements (called “pseudo-sensors”) will be compared to the system real-timedata. Comparison results will be utilized to provide systems operators with enhanced monitoring ofsystems' health and status, identify off-nominal trends and diagnose system/component failures.This capability can also be used to conduct planning and analysis of cryogenics and other fluidsystems designs. This capability will be interfaced with the ground operations command andcontrol system as a part of the Advanced Ground Systems Maintenance (AGSM) project to helpassure system availability and mission success. The initial capability will be developed for theLiquid Oxygen (LO2) ground loading systems.

  3. Which supplementary imaging modality should be used for breast ultrasonography? Comparison of the diagnostic performance of elastography and computer-aided diagnosis

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Si Eun; Moon, Ji Eun Ho; Kim, Eun Kyung; Yoon, Jung Hyun [Yonsei University College of Medicine, Seoul (Korea, Republic of)

    2017-04-15

    The aim of this study was to evaluate and compare the diagnostic performance of grayscale ultrasonography (US), US elastography, and US computer-aided diagnosis (US-CAD) in the differential diagnosis of breast masses. A total of 193 breast masses in 175 consecutive women (mean age, 46.4 years) from June to August 2015 were included. US and elastography images were obtained and recorded. A US-CAD system was applied to the grayscale sonograms, which were automatically analyzed and visualized in order to generate a final assessment. The final assessments of breast masses were based on the American College of Radiology Breast Imaging Reporting and Data System (BI-RADS) categories, while elasticity scores were assigned using a 5-point scoring system. The diagnostic performance of grayscale US, elastography, and US-CAD was calculated and compared. Of the 193 breast masses, 120 (62.2%) were benign and 73 (37.8%) were malignant. Breast masses had significantly higher rates of malignancy in BI-RADS categories 4c and 5, elastography patterns 4 and 5, and when the US-CAD assessment was possibly malignant (all P<0.001). Elastography had higher specificity (40.8%, P=0.042) than grayscale US. US-CAD showed the highest specificity (67.5%), positive predictive value (PPV) (61.4%), accuracy (74.1%), and area under the curve (AUC) (0.762, all P<0.05) among the three diagnostic tools. US-CAD had higher values for specificity, PPV, accuracy, and AUC than grayscale US or elastography. Computer-based analysis based on the morphologic features of US may be very useful in improving the diagnostic performance of breast US.

  4. Dose and diagnostic performance comparison between phase-contrast mammography with synchrotron radiation and digital mammography: a clinical study report.

    Science.gov (United States)

    Fedon, Christian; Rigon, Luigi; Arfelli, Fulvia; Dreossi, Diego; Quai, Elisa; Tonutti, Maura; Tromba, Giuliana; Cova, Maria Assunta; Longo, Renata

    2018-01-01

    Two dosimetric quantities [mean glandular dose (MGD) and entrance surface air kerma (ESAK)] and the diagnostic performance of phase-contrast mammography with synchrotron radiation (MSR) are compared to conventional digital mammography (DM). Seventy-one patients (age range, 41 to 82 years) underwent MSR after a DM examination if questionable or suspicious breast abnormalities were not clarified by ultrasonography. The MGD and the ESAK delivered in both examinations were evaluated and compared. Two on-site radiologists rated the images in consensus according to the Breast Imaging Reporting and Data System assessment categories, which were then correlated with the final diagnoses by means of statistical generalized linear models (GLMs). Receiver operating characteristic curves were also used to assess the diagnostic performance by comparing the area under the curve (AUC). An important MGD and ESAK reduction was observed in MSR due to the monoenergetic beam. In particular, an average 43% reduction was observed for the MGD and a reduction of more than 50% for the ESAK. GLM showed higher diagnostic accuracy, especially in terms of specificity, for MSR, confirmed by AUC analysis ([Formula: see text]). The study design implied that the population was characterized by a high prevalence of disease and that the radiologists, who read the DM images before referring the patient to MSR, could have been influenced in their assessments. Within these limitations, the use of synchrotron radiation with the phase-contrast technique applied to mammography showed an important dose reduction and a higher diagnostic accuracy compared with DM. These results could further encourage research on the translation of x-ray phase-contrast imaging into the clinics.

  5. System theory in medical diagnostic devices: an overview.

    Science.gov (United States)

    Baura, Gail D

    2006-01-01

    Medical diagnostics refers to testing conducted either in vitro or in vivo to provide critical health care information for risk assessment, early diagnosis, treatment, or disease management. Typical in vivo diagnostic tests include the computed tomography scan, magnetic resonance imaging, and blood pressure screening. Typical in vitro diagnostic tests include cholesterol, Papanicolaou smear, and conventional glucose monitoring tests. Historically, devices associated with both types of diagnostics have used heuristic curve fitting during signal analysis. However, since the early 1990s, a few enterprising engineers and physicians have used system theory to improve their core processing for feature detection and system identification. Current applications include automated Pap smear screening for detection of cervical cancer and diagnosis of Alzheimer's disease. Future applications, such as disease prediction before symptom onset and drug treatment customization, have been catalyzed by the Human Genome Project.

  6. Pathology Assistant (C - Gamechanger Of Pathology Diagnostic

    Directory of Open Access Journals (Sweden)

    Asel Kudaybergenova

    2016-06-01

    When the competition ended, we received many favor- able reviews and we decided to start another project a little bit similar to the competition. Every month we show three interesting and difficult to diagnose cases provided by the leading Russian pathologists. The participants can look through the clinical data and digitized histological slides, and then discuss what they see among their professional society. There are 400  specialists  from  post  USSR countries.  Moreover, we get a few proposal of partnership to start a similar project in EU. And the last product in line is Pathology Assistant. It is a game changer. Pathology Assistant is a Digital Pathology©technology driven application for pathology diagnostics, tool to innovate pathology diagnostics in more simple, proven by analytical algo- rithm, automatically delivering anticipated support way. The service provides vast and structured database of validated cases, intuitive interface, fast and convenient system of analytical search. Pathology Assistant will streamline and simplify pathologist’s way to the right decision. Pathologists from Memorial Sloan Catering and biggest EU labs are working on preparing the con- tent for the project.  

  7. An Evaluation of the Performance Diagnostic Checklist-Human Services (PDC-HS) Across Domains.

    Science.gov (United States)

    Wilder, David A; Lipschultz, Joshua; Gehrman, Chana

    2018-06-01

    The Performance Diagnostic Checklist-Human Services (PDC-HS) is an informant-based tool designed to assess the environmental variables that contribute to poor employee performance in human service settings. Although the PDC-HS has been shown to effectively identify variables contributing to problematic performance, interventions based on only two of the four PDC-HS domains have been evaluated to date. In addition, the extent to which PDC-HS-indicated interventions are more effective than nonindicated interventions for two domains remains unclear. In the current study, we administered the PDC-HS to supervisors to assess the variables contributing to infrequent teaching of verbal operants and use of a timer by therapists at a center-based autism treatment program. Each of the four PDC-HS domains was identified as contributing to poor performance for at least one therapist. We then evaluated PDC-HS-indicated interventions for each domain. In addition, to assess the predictive validity of the tool, we evaluated various nonindicated interventions prior to implementing a PDC-HS-indicated intervention for two of the four domains. Results suggest that the PDC-HS-indicated interventions were effective across all four domains and were more effective than the nonindicated interventions for the two domains for which they were evaluated. Results are discussed in terms of the utility of the PDC-HS to identify appropriate interventions to manage therapist performance in human service settings.

  8. Development of advanced diagnostic technologies for motor-operated valves

    International Nuclear Information System (INIS)

    Hegi, Kotaro; Shimizu, Shunichi; Higuma, Koji; Nishino, Koji; Osaki, Kenji; Watanabe, Kazumi; Hamano, Frank

    2010-01-01

    As use of condition-based maintenance is allowed in the new regulatory inspection system employed in Japan's nuclear power plants in 2009, development of advanced diagnostic technologies for motor-operated valves (MOVs) is now required. This report discusses advanced technologies in valve-setup verification, valve performance evaluation, monitoring of valve/actuator conditions by performance diagnostic system and moreover detection of stem crack by ultrasonic diagnostic system. (author)

  9. Establish radiation protection programme for diagnostic radiology

    International Nuclear Information System (INIS)

    Mboya, G.

    2014-01-01

    Mammography is an effective method used for breast diagnostics and screening. The aim of this project is to review the literature on how to establish radiation protection programme for mammography in order to protect the patients, the occupationally exposed workers and the members of the public from harmful effects of ionizing radiation. It reviews some of the trends in mammography doses and dosimetric principles such as average glandular dose in the glandular tissue which is used for description of radiation risk, also the factors affecting patient doses are discussed. However, the average glandular dose should not be used directly to estimate the radiation risk from mammography. Risk is calculated under certain assumptions from determined entrance surface air kerma. Given the increase in population dose, emphasis is placed on the justification and optimization of the mammographic procedures. Protection is optimized by the radiation dose being appropriate with the purpose of the mammographic examination. The need to establish diagnostic reference levels as an optimization is also discussed. In order to obtain high quality mammograms at low dose to the breast, it is necessary to use the correct equipment and perform periodic quality control tests on mammography equipment. It is noted that in order to achieve the goal of this project, the application of radiation protection should begin at the time of requesting for mammography examination, positioning of the patient, irradiation, image processing and interpretation of mammogram. It is recommended that close cooperation between radiology technologists, radiologist, medical physicists, regulatory authority and other support workers be required and established to obtain a consistent and effective level of radiation protection in a mammography facility. (author)

  10. Computer modeling and design of diagnostic workstations and radiology reading rooms

    Science.gov (United States)

    Ratib, Osman M.; Amato, Carlos L.; Balbona, Joseph A.; Boots, Kevin; Valentino, Daniel J.

    2000-05-01

    We used 3D modeling techniques to design and evaluate the ergonomics of diagnostic workstation and radiology reading room in the planning phase of building a new hospital at UCLA. Given serious space limitations, the challenge was to provide more optimal working environment for radiologists in a crowded and busy environment. A particular attention was given to flexibility, lighting condition and noise reduction in rooms shared by multiple users performing diagnostic tasks as well as regular clinical conferences. Re-engineering workspace ergonomics rely on the integration of new technologies, custom designed cabinets, indirect lighting, sound-absorbent partitioning and geometric arrangement of workstations to allow better privacy while optimizing space occupation. Innovations included adjustable flat monitors, integration of videoconferencing and voice recognition, control monitor and retractable keyboard for optimal space utilization. An overhead compartment protecting the monitors from ambient light is also used as accessory lightbox and rear-view projection screen for conferences.

  11. Diagnostic Accuracy of Focused Assessment with Sonography for Blunt Abdominal Trauma in Pediatric Patients Performed by Emergency Medicine Residents versus Radiology Residents

    Directory of Open Access Journals (Sweden)

    Farhad Heydari

    2018-05-01

    Full Text Available Introduction: Focused assessment with sonography for trauma (FAST has been shown to be useful to detect intraperitoneal free fluid in patients with blunt abdominal trauma (BAT. Objective: We compared the diagnostic accuracy of FAST performed by emergency medicine residents (EMRs and radiology residents (RRs in pediatric patients with BAT. Method: In this prospective study, pediatric patients with BAT and high energy trauma who were referred to the emergency department (ED at Al-Zahra and Kashani hospitals in Isfahan, Iran, were evaluated using FAST, first by EMRs and subsequently by RRs. The reports provided by the two resident groups were compared with the final outcome based on the results of the abdominal computed tomography (CT, operative exploration, and clinical observation. Results: A total of 101 patients with a median age of 6.75 ± 3.2 years were enrolled in the study between January 2013 and May 2014. These patients were evaluated using FAST, first by EMRs and subsequently by RRs. A good diagnostic agreement was noted between the results of the FAST scans performed by EMRs and RRs (κ = 0.865, P < 0.001. The sensitivity, specificity, positive and negative predictive values, and accuracy in evaluating the intraperitoneal free fluid were 72.2%, 85.5%, 52%, 93.3%, and 83.2%, respectively, when FAST was performed by EMRs and 72.2%, 86.7%, 54.2%, 93.5%, and 84.2%, respectively, when FAST was performed by RRs. No significant differences were seen between the EMR- and RR-performed FAST. Conclusion: In this study, FAST performed by EMRs had acceptable diagnostic value, similar to that performed by RRs, in patients with BAT.

  12. Final Report for 'Modeling Electron Cloud Diagnostics for High-Intensity Proton Accelerators'

    International Nuclear Information System (INIS)

    Veitzer, Seth A.

    2009-01-01

    Electron clouds in accelerators such as the ILC degrade beam quality and limit operating efficiency. The need to mitigate electron clouds has a direct impact on the design and operation of these accelerators, translating into increased cost and reduced performance. Diagnostic techniques for measuring electron clouds in accelerating cavities are needed to provide an assessment of electron cloud evolution and mitigation. Accurate numerical modeling of these diagnostics is needed to validate the experimental techniques. In this Phase I, we developed detailed numerical models of microwave propagation through electron clouds in accelerating cavities with geometries relevant to existing and future high-intensity proton accelerators such as Project X and the ILC. Our numerical techniques and simulation results from the Phase I showed that there was a high probability of success in measuring both the evolution of electron clouds and the effects of non-uniform electron density distributions in Phase II.

  13. Diagnostic performance of a rapid in-clinic test for the detection of Canine Parvovirus under different storage conditions and vaccination status.

    Science.gov (United States)

    Kantere, Maria C; Athanasiou, Labrini V; Spyrou, Vassiliki; Kyriakis, Constantinos S; Kontos, Vassilios; Chatzopoulos, Dimitrios C; Tsokana, Constantina N; Billinis, Charalambos

    2015-04-01

    Canine parvovirus (CPV) is one of the most common causes of acute haemorrhagic enteritis in young dogs, while clinical diagnosis is often indecisive. The aim of our study was to evaluate the diagnostic accuracy of an in-clinic rapid test in the detection of CPV infection in dogs. To this end, we compared the Rapid Diagnostic Kit of Canine Parvovirus, Coronavirus and Rotavirus antigen (Quicking(®)) to PCR, which is considered as the most reliable diagnostic method. A total of 78 duplicated faecal samples were collected from diarrhoeic dogs. Vaccination history within a month prior to the onset of diarrhoea was reported for 12 of the sampled dogs. The rapid diagnostic test was performed in 23 of the faecal samples directly, while the rest were placed into a sterile cotton tipped swab suitable for collection and transportation of viruses (Sigma Σ-VCM(®)) and stored at -20 °C. The sensitivity of the Quicking rapid diagnostic test compared to PCR in the total number of samples, in samples from non-vaccinated dogs and in samples tested directly after collection were 22.22% (95% CI: 13.27-33.57%), 26.67% (95% CI: 16.08-39.66%) and 76.47% (95% CI: 50.10-93.04%) respectively, while the specificity of the test was 100% in any case. In conclusion, negative results do not exclude parvoenteritis from the differential diagnosis, especially in dogs with early vaccination history, but a positive result almost certainly indicates CPV infection. An improved sensitivity may be expected when the test is performed immediately. Copyright © 2015 Elsevier B.V. All rights reserved.

  14. Comparison of diagnostic performance for perinatal and paediatric post-mortem imaging: CT versus MRI

    International Nuclear Information System (INIS)

    Arthurs, Owen J.; Jacques, Thomas S.; Sebire, Neil J.; Guy, Anna; Chong, W.K.; Gunny, Roxanna; Saunders, Dawn; Olsen, Oystein E.; Thayyil, Sudhin; Wade, Angie; Jones, Rod; Norman, Wendy; Taylor, Andrew M.; Scott, Rosemary; Robertson, Nicola J.; Owens, Catherine M.; Offiah, Amaka C.; Chitty, Lyn S.

    2016-01-01

    To compare the diagnostic yield of whole-body post-mortem computed tomography (PMCT) imaging to post-mortem magnetic resonance (PMMR) imaging in a prospective study of fetuses and children. We compared PMCT and PMMR to conventional autopsy as the gold standard for the detection of (a) major pathological abnormalities related to the cause of death and (b) all diagnostic findings in five different body organ systems. Eighty two cases (53 fetuses and 29 children) underwent PMCT and PMMR prior to autopsy, at which 55 major abnormalities were identified. Significantly more PMCT than PMMR examinations were non-diagnostic (18/82 vs. 4/82; 21.9 % vs. 4.9 %, diff 17.1 % (95 % CI 6.7, 27.6; p < 0.05)). PMMR gave an accurate diagnosis in 24/55 (43.64 %; 95 % CI 31.37, 56.73 %) compared to 18/55 PMCT (32.73 %; 95 % CI 21.81, 45.90). PMCT was particularly poor in fetuses <24 weeks, with 28.6 % (8.1, 46.4 %) more non-diagnostic scans. Where both PMCT and PMMR were diagnostic, PMMR gave slightly higher diagnostic accuracy than PMCT (62.8 % vs. 59.4 %). Unenhanced PMCT has limited value in detection of major pathology primarily because of poor-quality, non-diagnostic fetal images. On this basis, PMMR should be the modality of choice for non-invasive PM imaging in fetuses and children. (orig.)

  15. How to appraise a diagnostic test

    Directory of Open Access Journals (Sweden)

    Ramanitharan Manikandan

    2011-01-01

    Full Text Available Urologists frequently encounter problems in making a clinical diagnosis whose resolution requires the use of diagnostic tests. With an ever increasing choice of investigations being available, the urologist often has to decide which diagnostic test(s will best resolve the patient′s diagnostic problem. In this article, we aim to help the urologist understand how to critically appraise studies on diagnostic tests and make a rational choice. This article presents the guiding principles in scientifically assessing studies on diagnostic tests by proposing a clinical scenario. The authors describe a standardized protocol to assess the validity of the test and its relevance to the clinical problem that can help the urologist in decision making. The three important issues to be considered when evaluating the validity of the study are to identify how the study population was chosen, how the test was performed and whether there is a comparison to the gold standard test so as to confirm or refute the diagnosis. Then, the urologist would need to know the probability of the test in providing the correct diagnosis in an individual patient in order to decide about its utility in solving the diagnostic dilemma. By performing the steps described in this article, the urologist would be able to critically appraise diagnostic studies and draw meaningful conclusions about the investigations in terms of validity, results and its applicability to the patient′s problem. This would provide a scientific basis for using diagnostic tests for improving patient care.

  16. Evaluation and construction of diagnostic criteria for inclusion body myositis

    Science.gov (United States)

    Mammen, Andrew L.; Amato, Anthony A.; Weiss, Michael D.; Needham, Merrilee

    2014-01-01

    Objective: To use patient data to evaluate and construct diagnostic criteria for inclusion body myositis (IBM), a progressive disease of skeletal muscle. Methods: The literature was reviewed to identify all previously proposed IBM diagnostic criteria. These criteria were applied through medical records review to 200 patients diagnosed as having IBM and 171 patients diagnosed as having a muscle disease other than IBM by neuromuscular specialists at 2 institutions, and to a validating set of 66 additional patients with IBM from 2 other institutions. Machine learning techniques were used for unbiased construction of diagnostic criteria. Results: Twenty-four previously proposed IBM diagnostic categories were identified. Twelve categories all performed with high (≥97%) specificity but varied substantially in their sensitivities (11%–84%). The best performing category was European Neuromuscular Centre 2013 probable (sensitivity of 84%). Specialized pathologic features and newly introduced strength criteria (comparative knee extension/hip flexion strength) performed poorly. Unbiased data-directed analysis of 20 features in 371 patients resulted in construction of higher-performing data-derived diagnostic criteria (90% sensitivity and 96% specificity). Conclusions: Published expert consensus–derived IBM diagnostic categories have uniformly high specificity but wide-ranging sensitivities. High-performing IBM diagnostic category criteria can be developed directly from principled unbiased analysis of patient data. Classification of evidence: This study provides Class II evidence that published expert consensus–derived IBM diagnostic categories accurately distinguish IBM from other muscle disease with high specificity but wide-ranging sensitivities. PMID:24975859

  17. MFTF plasma diagnostics data acquisition system

    International Nuclear Information System (INIS)

    Davis, G.E.; Coffield, F.E.

    1979-01-01

    The initial goal of the Data Acquisition System (DAS) is to control 11 instruments chosen as the startup diagnostic set and to collect, process, and display the data that these instruments produce. These instruments are described in a paper by Stan Thomas, et. al. entitled ''MFTF Plasma Diagnostics System.'' The DAS must be modular and flexible enough to allow upgrades in the quantity of data taken by an instrument, and also to allow new instruments to be added to the system. This is particularly necessary to support a research project where needs and requirements may change rapidly as a result of experimental findings. Typically, the startup configuration of the diagnostic instruments will contain only a fraction of the planned detectors, and produce approximately one half the data that the expanded version is designed to generate. Expansion of the system will occur in fiscal year 1982

  18. Information engineering for molecular diagnostics.

    Science.gov (United States)

    Sorace, J. M.; Ritondo, M.; Canfield, K.

    1994-01-01

    Clinical laboratories are beginning to apply the recent advances in molecular biology to the testing of patient samples. The emerging field of Molecular Diagnostics will require a new Molecular Diagnostics Laboratory Information System which handles the data types, samples and test methods found in this field. The system must be very flexible in regards to supporting ad-hoc queries. The requirements which are shaping the developments in this field are reviewed and a data model developed. Several queries which demonstrate the data models ability to support the information needs of this area have been developed and run. These results demonstrate the ability of the purposed data model to meet the current and projected needs of this rapidly expanding field. PMID:7949937

  19. Hydrogen engine performance analysis project. Second annual report

    Energy Technology Data Exchange (ETDEWEB)

    Adt, Jr., R. R.; Swain, M. R.; Pappas, J. M.

    1980-01-01

    Progress in a 3 year research program to evaluate the performance and emission characteristics of hydrogen-fueled internal combustion engines is reported. Fifteen hydrogen engine configurations will be subjected to performance and emissions characterization tests. During the first two years, baseline data for throttled and unthrottled, carburetted and timed hydrogen induction, Pre IVC hydrogen-fueled engine configurations, with and without exhaust gas recirculation (EGR) and water injection, were obtained. These data, along with descriptions of the test engine and its components, the test apparatus, experimental techniques, experiments performed and the results obtained, are given. Analyses of other hydrogen-engine project data are also presented and compared with the results of the present effort. The unthrottled engine vis-a-vis the throttled engine is found, in general, to exhibit higher brake thermal efficiency. The unthrottled engine also yields lower NO/sub x/ emissions, which were found to be a strong function of fuel-air equivalence ratio. (LCL)

  20. SKI SITE-94. Deep Repository Performance Assessment Project Volume I and II

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1996-12-01

    The function of SITE-94 is to provide the Swedish Nuclear Power Inspectorate (SKI) with the capacity and supporting knowledge needed for reviewing the Swedish nuclear industry`s R and D programs and for reviewing license applications, as stipulated in Swedish legislation. The report is structured as a Performance Assessment exercise needed for input to decisions regarding repository safety, but the SITE-94 is not a safety assessment or a model for future assessments to be undertaken by the prospective licensee. The specific project objectives of SITE-94 comprise site evaluation, performance assessment methodology, canister integrity and radionuclide release and transport calculations. The report gives a detailed description of the many inter-related studies undertaken as part of the research project. As a general conclusion it is noted that the SITE-94 project has significantly advanced SKI`s capability of reviewing performance assessments and has led to the development of a tool-kit for carrying out assessment calculations, both in terms of numerical and scoping analyses. The study has highlighted a number of key issues for safety assessment (and consequently for disposal system design): Canister performance; Derived parameters of geosphere retention properties; Spatial variability of groundwater flow and geochemistry of migration paths; Time dependency (more emphasis on transient, time-dependent processes); Buffer evolution over long time. 488 refs.

  1. SKI SITE-94. Deep Repository Performance Assessment Project Volume I and II

    International Nuclear Information System (INIS)

    1996-12-01

    The function of SITE-94 is to provide the Swedish Nuclear Power Inspectorate (SKI) with the capacity and supporting knowledge needed for reviewing the Swedish nuclear industry's R and D programs and for reviewing license applications, as stipulated in Swedish legislation. The report is structured as a Performance Assessment exercise needed for input to decisions regarding repository safety, but the SITE-94 is not a safety assessment or a model for future assessments to be undertaken by the prospective licensee. The specific project objectives of SITE-94 comprise site evaluation, performance assessment methodology, canister integrity and radionuclide release and transport calculations. The report gives a detailed description of the many inter-related studies undertaken as part of the research project. As a general conclusion it is noted that the SITE-94 project has significantly advanced SKI's capability of reviewing performance assessments and has led to the development of a tool-kit for carrying out assessment calculations, both in terms of numerical and scoping analyses. The study has highlighted a number of key issues for safety assessment (and consequently for disposal system design): Canister performance; Derived parameters of geosphere retention properties; Spatial variability of groundwater flow and geochemistry of migration paths; Time dependency (more emphasis on transient, time-dependent processes); Buffer evolution over long time. 488 refs

  2. Impact of Dupoto-e-Maa education project on dropout rate and academic performance

    Directory of Open Access Journals (Sweden)

    James B. Ouda

    2016-09-01

    Conclusion: The study recommended that there is need to increase the number of non-governmental organisations modelled around the Dupoto-e-Maa education project so as to reduce dropout rate and improve pupil academic performance. The findings could also inform government policy in terms of recruitment and placement of teachers in schools in arid and semi-arid lands. Project funding could be increased to improve visibility and sustainability of project activities.

  3. Diagnostic Suite for HyperV Coaxial Plasma Gun Development for the PLX- α Project

    Science.gov (United States)

    Case, Andrew; Brockington, Sam; Witherspoon, F. Douglas

    2015-11-01

    We present the diagnostic suite to be used during development of the coaxial guns HyperV will deliver to LANL in support of the ARPA-E Accelerating Low-Cost Plasma Heating And Assembly (ALPHA) program. For plasma jet diagnostics this includes fast photodiodes for velocimetry, a ballistic pendulum for measuring total plasmoid momentum, interferometry for line integrated plasma density, deflectometry for line integrated perpendicular density gradient measurements, and spectroscopy, both time resolved high resolution spectroscopy using a novel detector developed by HyperV and time integrated survey spectroscopy, for measurements of velocity and temperature as well as impurities. In addition, we plan to use fast pressure probes for stagnation pressure, a Faraday cup for density, fast imaging for plume geometry and time integrated imaging for overall light emission. A novel low resolution long record length camera developed by HyperV will also be used for plume diagnostics. For diagnostics of gun operation, we will use Rogowski coils to measure current, voltage dividers for voltages, B-dot probes for magnetic field, and time resolved fast photodiodes to measure plasmoid velocity inside the accelerator. This work supported by the ARPA-E ALPHA program.

  4. Plasma diagnostics for the compact ignition tokamak

    International Nuclear Information System (INIS)

    Medley, S.S.; Young, K.M.

    1988-06-01

    The primary mission of the Compact Ignition Tokamak (CIT) is to study the physics of alpha-particle heating in an ignited D-T plasma. A burn time of about 10 /tau//sub E/ is projected in a divertor configuration with baseline machine design parameters of R=2.10 m, 1=0.65 m, b=1.30 m, I/sub p/=11 MA, B/sub T/=10 T and 10-20 MW of auxiliary rf heating. Plasma temperatures and density are expected to reach T/sub e/(O) /approximately/20 keV, T/sub i/(O) /approximately/30 keV, and n/sub e/(O) /approximately/ 1 /times/ 10 21 m/sup /minus/3/. The combined effects of restricted port access to the plasma, the presence of severe neutron and gamma radiation backgrounds, and the necessity for remote of in-cell components create challenging design problems for all of the conventional diagnostic associated with tokamak operations. In addition, new techniques must be developed to diagnose the evolution in space, time, and energy of the confined alpha distribution as well as potential plasma instabilities driven by collective alpha-particle effects. The design effort for CIT diagnostics is presently in the conceptual phase with activity being focused on the selection of a viable diagnostic set and the identification of essential research and development projects to support this process. A review of these design issues and other aspects impacting the selection of diagnostic techniques for the CIT experiment will be presented. 28 refs., 10 figs., 2 tabs

  5. Diagnostic performance of neck circumference to identify overweight and obesity as defined by body mass index in children and adolescents: systematic review and meta-analysis.

    Science.gov (United States)

    Ma, Chunming; Wang, Rui; Liu, Yue; Lu, Qiang; Liu, Xiaoli; Yin, Fuzai

    2017-05-01

    The neck circumference (NC) has been shown to be an accurate index for screening overweight and obesity in children and adolescents. To perform a meta-analysis to assess the performance of NC for the assessment of overweight and obesity. Data sources were PubMed and EMBASE up to March 2016. Studies providing measures of diagnostic performance of NC and using body mass index as reference standard were included. Six eligible studies that evaluated 11 214 children and adolescents aged 6-18 years were included in the meta-analysis. NC showed pooled sensitivity to detect high body mass index of 0.780 (95% confidence interval [CI] = 0.765-0.794), specificity of 0.746 (95% CI =  0.736-0.756) and a diagnostic odds ratio of 17.343 (95% CI =  8.743-34.405). The NC had moderate diagnostic accuracy for identifying overweight and obesity in children and adolescents.

  6. Polychromatic holographic plasma diagnostics

    International Nuclear Information System (INIS)

    Zhiglinskij, A.G.; Morozov, A.O.

    1992-01-01

    Review of holographic interferometry properties is performed and advantages of this method by plasma diagnostics are indicated. Main results obtained by the method of holographic interferometry in studies of various-type plasmas are considered. Special attention is paid to multiwave plasma diagnostics, the necessity of which is related as a rule to multicomponent composition of plasma. The eight laser and gas-discharge sources and holographic schemes, which make it possible to realize plasma polychromatic and holographic interferometry, are considered. The advantages of the method are demonstrated by examples of polychromatic holographic diagnostics of arc discharge and discharge in a hollow cathode. Review of theoretical works determining the applicability area of resonance polychromatic interferometry is carried out

  7. Advanced Diagnostics in Oxy-Fuel Combustion Processes

    DEFF Research Database (Denmark)

    Brix, Jacob; Toftegaard, Maja Bøg; Clausen, Sønnik

    This report sums up the findings in PSO-project 010069, “Advanced Diagnostics in Oxy- Fuel Combustion Processes”. Three areas of optic diagnostics are covered in this work: - FTIR measurements in a 30 kW swirl burner. - IR measurements in a 30 kW swirl burner. - IR measurements in a laboratory...... technique was an invaluable tool in the discussion of data obtained by gas analysis, and it allowed for estimation of combustion times in O2/CO2 where the high CO2 concentration prevents the use of the carbon mass balance for that purpose. During the project the data have been presented at a conference......, formed the basis of a publication and it is part of two PhD dissertations. The name of the conference the journal and the dissertations are listed below. - Joint Meeting of the Scandinavian-Nordic and French Sections of the Combustion Institute, Combustion of Char Particles under Oxy-Fuel Conditions...

  8. Diagnostic performance of a novel cadmium-zinc-telluride gamma camera system assessed using fractional flow reserve.

    Science.gov (United States)

    Tanaka, Hirokazu; Chikamori, Taishiro; Tanaka, Nobuhiro; Hida, Satoshi; Igarashi, Yuko; Yamashita, Jun; Ogawa, Masashi; Shiba, Chie; Usui, Yasuhiro; Yamashina, Akira

    2014-01-01

    Although the novel cadmium-zinc-telluride (CZT) camera system provides excellent image quality, its diagnostic value using thallium-201 as assessed on coronary angiography (CAG) and fractional flow reserve (FFR) has not been validated. METHODS AND RESULTS: To evaluate the diagnostic accuracy of the CZT ultrafast camera system (Discovery NM 530c), 95 patients underwent stress thallium-201 single-photon emission computed tomography (SPECT) and then CAG within 3 months. Image acquisition was performed in the supine and prone positions after stress for 5 and 3 min, respectively, and in the supine position at rest for 10 min. Significant stenosis was defined as ≥90% diameter narrowing on visual estimation, or a lesion with <90% and ≥50% stenosis and FFR ≤0.75. To detect individual coronary stenosis, the respective sensitivity, specificity, and accuracy were 90%, 64%, and 78% for left anterior descending coronary artery stenosis, 78%, 84%, and 81% for left circumflex stenosis, and 83%, 47%, and 60% for right coronary artery (RCA) stenosis. The combination of prone and supine imaging had a higher specificity for RCA disease than supine imaging alone (65% vs. 47%), with an improvement in accuracy from 60% to 72%. Using thallium-201 with short acquisition time, combined with prone imaging, CZT SPECT had a high diagnostic yield in detecting significant coronary stenosis as assessed using FFR.

  9. The status of the LANSCE refurbishment project (LANSCE-R)

    International Nuclear Information System (INIS)

    Erickson, John Leonard; Jones, Kevin; Streve, Michael

    2008-01-01

    The Los Alamos Neutron Science Center (LANSCE) accelerator is an 800-MeV proton linac that drives user facilities for isotope production, proton radiography, ultra-cold neutrons, weapons neutron research and various sciences using neutron scattering. The LANSCE Refurbishment Project (LANSCE-R) is an ambitious project to refurbish key elements of the LANSCE accelerator that are becoming obsolete or nearing end-of-life. The conceptual design phase for the project is funded and underway. The 5 year, $170M (US) project will enable future decades of reliable, high-performance operation. It will replace a substantial fraction of the radio-frequency power systems (gridded tubes and klystrons) with modern systems, completely refurbish the original accelerator control and timing systems, replace obsolete diagnostic devices, and modernize other ancillary systems. An overview of the LANSCE-R project will be presented. The functional and operating requirements will be discussed, the proposed technical solutions presented, and the plan for successful project execution while meeting annual customer expectations for beam delivery will be reviewed.

  10. Nordic working group for medical x-ray diagnostics: Diagnostic reference levels within xray diagnostics - experiences in the Nordic countries

    International Nuclear Information System (INIS)

    Leitz, W.; Groen, P.; Servomaa, A.; Einarsson, G.; Olerud, H.

    2003-01-01

    Medical x-ray diagnostics is one of the few applications of ionising radiation where people are irradiated on purpose. The strategy for radiation protection is also different compared to that in other areas that have the zero-alternative as its ultimate goal, meaning that no human beings at all are exposed in these practices. The focus in x-ray diagnostics concerning radiation protection is justification and optimisation. Optimisation implies that the examination is performed in such a way that the radiation dose is as small as possible without jeopardising the diagnostic security. X- ray diagnostics is a complex method where many technical parameters and methodology factors together are interacting in the determination of radiation dose and image quality. The optimisation process is not a simple and uncomplicated procedure, this difficulty is reflected in many international and national surveys showing a large spread of patient doses for one and the same type of examination. The concept diagnostic reference levels (DRL) has been introduced as a tool for reducing this wide distribution that is obviously indicating a lack of optimisation, and for cutting the highest radiation doses. In this presentation the concept for DRL and the experience gained in the Nordic countries with DRL are described. (orig.)

  11. Economic Performance Analysis of National Research and Development Project

    Energy Technology Data Exchange (ETDEWEB)

    Kim, S. S.; Yun, S. W.; Kim, S. E. [KAERI, Daejeon (Korea, Republic of)

    2016-05-15

    There are a lot of differences between these two evaluation programs in terms of their main objectives, assessment items, and evaluation methods by item. When considering the recent evaluation trend of being more concerned with the objective and scientifically well-founded base of judgment than the qualitative results data, there seems to be much supplement and improvement points in both evaluation programs. Firstly, the MSIP's evaluation program which is known as 'The performance analysis of national R and D program in Korea is applying the principle of ex-post evaluation for the overall performances of R and D activities focusing on the scientific and technological outputs, economic effects, and social performances such as the training of science and engineering personnel. Its report has been done and published by the collaboration of MSIP and KISTEP(Korea Institute of Science and Technology Evaluation and Planning). There seems to be a trend that the economic contributions to the national economy and the industries by national R and D projects have been underestimated due to the difficulties of not presenting properly the reliable quantitative effects even though they have contributed not only to the real economy and economic growth but to the industrial productions and public benefits. The key reasons to this phenomenon might be the deficiency of perception for evaluation tools and methodologies development and the original difficulty of evaluation for R and D performances. Especially the evaluation results for national R and D projects could impact on the investment decision on the long-term national R and D program, with being based on the investment efficiency or the necessity and urgency which might be represented by evaluation results.

  12. Economic Performance Analysis of National Research and Development Project

    International Nuclear Information System (INIS)

    Kim, S. S.; Yun, S. W.; Kim, S. E.

    2016-01-01

    There are a lot of differences between these two evaluation programs in terms of their main objectives, assessment items, and evaluation methods by item. When considering the recent evaluation trend of being more concerned with the objective and scientifically well-founded base of judgment than the qualitative results data, there seems to be much supplement and improvement points in both evaluation programs. Firstly, the MSIP's evaluation program which is known as 'The performance analysis of national R and D program in Korea is applying the principle of ex-post evaluation for the overall performances of R and D activities focusing on the scientific and technological outputs, economic effects, and social performances such as the training of science and engineering personnel. Its report has been done and published by the collaboration of MSIP and KISTEP(Korea Institute of Science and Technology Evaluation and Planning). There seems to be a trend that the economic contributions to the national economy and the industries by national R and D projects have been underestimated due to the difficulties of not presenting properly the reliable quantitative effects even though they have contributed not only to the real economy and economic growth but to the industrial productions and public benefits. The key reasons to this phenomenon might be the deficiency of perception for evaluation tools and methodologies development and the original difficulty of evaluation for R and D performances. Especially the evaluation results for national R and D projects could impact on the investment decision on the long-term national R and D program, with being based on the investment efficiency or the necessity and urgency which might be represented by evaluation results

  13. A Framework to Debug Diagnostic Matrices

    Science.gov (United States)

    Kodal, Anuradha; Robinson, Peter; Patterson-Hine, Ann

    2013-01-01

    Diagnostics is an important concept in system health and monitoring of space operations. Many of the existing diagnostic algorithms utilize system knowledge in the form of diagnostic matrix (D-matrix, also popularly known as diagnostic dictionary, fault signature matrix or reachability matrix) gleaned from physical models. But, sometimes, this may not be coherent to obtain high diagnostic performance. In such a case, it is important to modify this D-matrix based on knowledge obtained from other sources such as time-series data stream (simulated or maintenance data) within the context of a framework that includes the diagnostic/inference algorithm. A systematic and sequential update procedure, diagnostic modeling evaluator (DME) is proposed to modify D-matrix and wrapper logic considering least expensive solution first. This iterative procedure includes conditions ranging from modifying 0s and 1s in the matrix, or adding/removing the rows (failure sources) columns (tests). We will experiment this framework on datasets from DX challenge 2009.

  14. Pediatric echocardiograms performed at primary centers: Diagnostic errors and missing links!

    International Nuclear Information System (INIS)

    Saraf, Rahul P; Suresh, PV; Maheshwari, Sunita; Shah, Sejal S

    2015-01-01

    The present study was undertaken to assess the accuracy of pediatric echocardiograms done at non-tertiary centers and to evaluate the relationship of inaccurate interpretations with age, echocardiogram performer and complexity of congenital heart disease (CHD). The echocardiogram reports of 182 consecutive children with CHD (5 days-16 years) who were evaluated at a non-tertiary center and subsequently referred to our center were reviewed. Age of the child at echocardiogram, echocardiogram performer and complexity of CHD were noted. These reports were compared with echocardiogram done at our center. Discrepancies were noted and categorized. To assess our own error rate, we compared our echocardiogram reports with the findings obtained during surgery (n = 172), CT scan (n = 9) or cardiac catheterization reports (n = 1). Most of the children at the non-tertiary center (92%) underwent echocardiogram by personnel other than a pediatric cardiologist. Overall, diagnostic errors were found in 69/182 (38%) children. Moderate and major discrepancies affecting the final management were found in 42/182 (23%) children. Discrepancies were higher when the echocardiogram was done by personnel other than pediatric cardiologist (P < 0.01) and with moderate and high complexity lesions (P = 0.0001). There was no significant difference in proportion of these discrepancies in children ≤ 1 year vs. >1 year of age. A significant number of pediatric echocardiograms done at non-tertiary centers had discrepancies that affected the management of these children. More discrepancies were seen when the echocardiogram performer was not a pediatric cardiologist and with complex CHD

  15. Leishmania Surveillance and Diagnostic Capability in Support of the Joint Biological Agent Identification and Diagnostic System (JBAIDS) and Leishmania Vector Surveillance

    Science.gov (United States)

    2013-02-07

    01-10-09 to 07-02-13 ’+. I II L~ J.\\NU :::OU~ Ill L~ :la. l-UI’I I 11J.\\l- I NUIVI~~I1 LEISHMANIA SURVEILLANCE AND DIAGNOSTIC CAPABILITY IN None...SUPPORT OF THE JOINT BIOLOGICAL AGENT IDENTIFICATION AND :lD. l:JI1J.\\NI NUIVI~~I1 DIAGNOSTIC SYSTEM (JBAIDS) None . ./ LEISHMANIA VECTOR...Field Station at Kisumu completed project activities through a resource sharing arrangement with the 59th MDW. Testing of the Leishmania epidemiology

  16. Diagnostic Performance and Utility of Quantitative EEG Analyses in Delirium: Confirmatory Results From a Large Retrospective Case-Control Study.

    Science.gov (United States)

    Fleischmann, Robert; Tränkner, Steffi; Bathe-Peters, Rouven; Rönnefarth, Maria; Schmidt, Sein; Schreiber, Stephan J; Brandt, Stephan A

    2018-03-01

    The lack of objective disease markers is a major cause of misdiagnosis and nonstandardized approaches in delirium. Recent studies conducted in well-selected patients and confined study environments suggest that quantitative electroencephalography (qEEG) can provide such markers. We hypothesize that qEEG helps remedy diagnostic uncertainty not only in well-defined study cohorts but also in a heterogeneous hospital population. In this retrospective case-control study, EEG power spectra of delirious patients and age-/gender-matched controls (n = 31 and n = 345, respectively) were fitted in a linear model to test their performance as binary classifiers. We subsequently evaluated the diagnostic performance of the best classifiers in control samples with normal EEGs (n = 534) and real-world samples including pathologic findings (n = 4294). Test reliability was estimated through split-half analyses. We found that the combination of spectral power at F3-P4 at 2 Hz (area under the curve [AUC] = .994) and C3-O1 at 19 Hz (AUC = .993) provided a sensitivity of 100% and a specificity of 99% to identify delirious patients among normal controls. These classifiers also yielded a false positive rate as low as 5% and increased the pretest probability of being delirious by 57% in an unselected real-world sample. Split-half reliabilities were .98 and .99, respectively. This retrospective study yielded preliminary evidence that qEEG provides excellent diagnostic performance to identify delirious patients even outside confined study environments. It furthermore revealed reduced beta power as a novel specific finding in delirium and that a normal EEG excludes delirium. Prospective studies including parameters of pretest probability and delirium severity are required to elaborate on these promising findings.

  17. Lithium beam diagnostic system on the COMPASS tokamak

    Czech Academy of Sciences Publication Activity Database

    Anda, G.; Bencze, A.; Berta, Miklós; Dunai, D.; Háček, Pavel; Krbec, Jaroslav; Réfy, D.; Krizsanóczi, T.; Bató, S.; Ilkei, T.; Kiss, I.G.; Veres, G.; Zoletnik, S.

    2016-01-01

    Roč. 108, October (2016), s. 1-6 ISSN 0920-3796 R&D Projects: GA MŠk(CZ) LM2011021 EU Projects: European Commission(XE) 633053 - EUROfusion Institutional support: RVO:61389021 Keywords : BES * Plasma diagnostics * COMPASS tokamak Plasma density profile Plasma current fluctuations * Plasma density profile * Plasma current fluctuations Subject RIV: JF - Nuclear Energetics OBOR OECD: Nuclear related engineering Impact factor: 1.319, year: 2016 http://www.sciencedirect.com/science/article/pii/S0920379616303131

  18. Diagnostic performance of dual-energy CT stress myocardial perfusion imaging: direct comparison with cardiovascular MRI.

    Science.gov (United States)

    Ko, Sung Min; Song, Meong Gun; Chee, Hyun Kun; Hwang, Hweung Kon; Feuchtner, Gudrun Maria; Min, James K

    2014-12-01

    The purpose of this study was to assess the diagnostic performance of stress perfusion dual-energy CT (DECT) and its incremental value when used with coronary CT angiography (CTA) for identifying hemodynamically significant coronary artery disease. One hundred patients with suspected or known coronary artery disease without chronic myocardial infarction detected with coronary CTA underwent stress perfusion DECT, stress cardiovascular perfusion MRI, and invasive coronary angiography (ICA). Stress perfusion DECT and cardiovascular stress perfusion MR images were used for detecting perfusion defects. Coronary CTA and ICA were evaluated in the detection of ≥50% coronary stenosis. The diagnostic performance of coronary CTA for detecting hemo-dynamically significant stenosis was assessed before and after stress perfusion DECT on a per-vessel basis with ICA and cardiovascular stress perfusion MRI as the reference standard. The performance of stress perfusion DECT compared with cardiovascular stress perfusion MRI on a per-vessel basis in the detection of perfusion defects was sensitivity, 89%; specificity, 74%; positive predictive value, 73%; negative predictive value, 90%. Per segment, these values were sensitivity, 76%; specificity, 80%; positive predictive value, 63%; and negative predictive value, 88%. Compared with ICA and cardiovascular stress perfusion MRI per vessel territory the sensitivity, specificity, positive predictive value, and negative predictive value of coronary CTA were 95%, 61%, 61%, and 95%. The values for stress perfusion DECT were 92%, 72%, 68%, and 94%. The values for coronary CTA and stress perfusion DECT were 88%, 79%, 73%, and 91%. The ROC AUC increased from 0.78 to 0.84 (p=0.02) with the use of coronary CTA and stress perfusion DECT compared with coronary CTA alone. Stress perfusion DECT plays a complementary role in enhancing the accuracy of coronary CTA for identifying hemodynamically significant coronary stenosis.

  19. Evaluation of safe performance secondary school driver education curriculum demonstration project

    Science.gov (United States)

    1983-06-01

    The primary objective of this Project was to determine the crash reduction potential of a quality, competency-based driver training program known as the Safe Performance Curriculum (SPC). The experimental design called for the random assignment of 18...

  20. The application of automated deductive reasoning to power plant diagnostics

    International Nuclear Information System (INIS)

    Filshtein, E.L.; Rzasa, P.W.

    1986-01-01

    A module which incorporates the application of deductive reasoning to diagnostics has been developed. This module is a part of a generic diagnostic expert system prototype developed for power plant operations at Combustion Engineering. This paper is one of a series of papers which will describe the activities of the project. Specifically, this paper describes the deductive reasoning module which determines and classifies root cause malfunctions. The concept of 'perfect instruments' is introduced. These instruments are imaginary instruments which bridge the gap between real world inputs and the generic diagnostic shell. The prototype, its application, and future developments are discussed

  1. Performance of NCAP projection displays

    Science.gov (United States)

    Jones, Philip J.; Tomita, Akira; Wartenberg, Mark

    1991-08-01

    Prototypes of projection displays based on dispersions of liquid crystal in polymer matrices are beginning to appear. The principle of operation depends on electrically switchable light scattering. They are potentially much brighter than current cathode ray tube (CRT) or twisted nematic liquid crystal (TN LC) cell based displays. Comparisons of efficacy and efficiency show this. The contrast and brightness of such displays depend on a combination of the f- number of the projection system and the scattering characteristics of the light valve. Simplified equations can be derived to show these effects. The degree of scattering of current NCAP formulations is sufficient to produce good contrast projection displays, at convenient voltages, that are around three times brighter than TN LC projectors because of the lack of polarizers in the former.

  2. CIT diagnostic computer interface studies

    International Nuclear Information System (INIS)

    Rauch, W.; Hayes, S.; Lowrance, J.; Oliaro, G.; Sauthoff, N.; Sichta, P.; Stark, W.

    1987-01-01

    This paper presents the on-going work performed in proposing instrumentation equipment and communications networks for the Diagnostic Data Acquisition and Diagnostic Instrumentation and Control System for the Compact Ignition Torus (CIT), which will begin operation in 1993. Consideration is given to the system criteria and requirements and their influence on the appropriate application of instrumentation and communication technologies to the system. This paper concentrates on the investigation of the bus communication technologies as they apply to the CIT data acquisition system. It compares CAMAC, VME, and FASTBUS as standards for data acquisition. The paper describes the connectivity between VAX equipment and CAMAC and VME instrumentation systems. Instrumentation and communication functionality and performance levels are presented as factors important to the overall data acquisition system performance

  3. Investigation and performance tests of a new parallel plate ionization chamber with double sensitive volume for measuring diagnostic X-rays

    Energy Technology Data Exchange (ETDEWEB)

    Sharifi, B., E-mail: babak_sharifi88@yahoo.com [Graduate University of Advanced Technology, Kerman (Iran, Islamic Republic of); Zamani Zeinali, H. [Application of Radiation Research School, Nuclear Science and Technology Research Institute, AEOI, Karaj (Iran, Islamic Republic of); Soltani, J.; Negarestani, A. [Graduate University of Advanced Technology, Kerman (Iran, Islamic Republic of); Shahvar, A. [Application of Radiation Research School, Nuclear Science and Technology Research Institute, AEOI, Karaj (Iran, Islamic Republic of)

    2015-01-11

    Medical diagnostic equipment, like diagnostic radiology and mammography require a dosimeter with high accuracy for dosimetry of the diagnostic X-ray beam. Ionization chambers are suitable instruments for dosimetry of diagnostic-range X-ray beams because of their appropriate response and high reliability. This work introduces the design and fabrication of a new parallel plate ionization chamber with a PMMA body, graphite-coated PMMA windows (0.5 mm thick) and a graphite-foil central electrode (0.1 mm thick, 0.7 g/cm{sup 3} dense). This design improves upon the response characteristics of existing designs through the specific choice of materials as well as the appropriate size and arrangement of the ionization chamber components. The results of performance tests conducted at the Secondary Standard Dosimetry laboratory in Karaj-Iran demonstrated the short and long-term stability, the low leakage current, the low directional dependence, and the high ion collection efficiency of the design. Furthermore, the FLUKA Monte Carlo simulations confirmed the low effect of central electrode on this new ionization chamber response. The response characteristics of the parallel plate ionization chamber presented in this work makes the instrument suitable for use as a standard dosimeter in laboratories.

  4. Metal artifact suppression at the hip: diagnostic performance at 3.0 T versus 1.5 Tesla

    Energy Technology Data Exchange (ETDEWEB)

    Nardo, Lorenzo; Han, Misung; Kretschmar, Martin; Krug, Roland; Link, Thomas M. [University of California San Francisco, Musculoskeletal and Quantitative Imaging Research, Department of Radiology and Biomedical Imaging, San Francisco, CA (United States); Guindani, Michele [The University of Texas MD Anderson Cancer Center, Department of Biostatistics - Unit 1411, Houston, TX (United States); Koch, Kevin [Medical College of Wisconsin, Department of Biophysics, Milwaukee, WI (United States); Medical College of Wisconsin, Department of Radiology, Milwaukee, WI (United States); Vail, Thomas [University of California San Francisco, Department of Orthopedic Surgery, San Francisco, CA (United States)

    2015-11-15

    This work aimed to compare the diagnostic performance of a metal artifact suppression sequence (MAVRIC-SL) for imaging of hip arthroplasties (HA) at 1.5 and 3 Tesla (T) field strength. Eighteen patients (10 females; aged 27-74) with HA were examined at 3.0 and 1.5 T within 3 weeks. The sequence protocol included 3D-MAVRIC-SL PD (coronal), 3D-MAVRIC-SL STIR (axial), FSE T1, FSE PD and STIR sequences. Anatomical structures and pathological findings were assessed independently by two radiologists. Artifact extent and technical quality (image quality, fat saturation and geometric distortion) were also evaluated. Findings at 1.5 and 3.0 T were compared using a Wilcoxon signed rank test. While image quality was better at 1.5 T, visualization of anatomic structures and clinical abnormalities was not significantly different using the two field strengths (p > 0.05). Fat suppression and amount of artifacts were significantly better at 1.5 T (p < 0.01). Inter- and intra-reader agreement for different anatomic details, image quality and visualization of abnormalities ranged from k = 0.62 to k = 1.00. MAVRIC-SL at 1.5 T had a comparable diagnostic performance when compared MAVRIC-SL at 3.0 T; however, the higher field strength was associated with larger artifacts, limited image quality and worse fat saturation. (orig.)

  5. Visually assessed colour overlay features in shear-wave elastography for breast masses: quantification and diagnostic performance.

    Science.gov (United States)

    Gweon, Hye Mi; Youk, Ji Hyun; Son, Eun Ju; Kim, Jeong-Ah

    2013-03-01

    To determine whether colour overlay features can be quantified by the standard deviation (SD) of the elasticity measured in shear-wave elastography (SWE) and to evaluate the diagnostic performance for breast masses. One hundred thirty-three breast lesions in 119 consecutive women who underwent SWE before US-guided core needle biopsy or surgical excision were analysed. SWE colour overlay features were assessed using two different colour overlay pattern classifications. Quantitative SD of the elasticity value was measured with the region of interest including the whole breast lesion. For the four-colour overlay pattern, the area under the ROC curve (Az) was 0.947; with a cutoff point between pattern 2 and 3, sensitivity and specificity were 94.4 % and 81.4 %. According to the homogeneity of the elasticity, the Az was 0.887; with a cutoff point between reasonably homogeneous and heterogeneous, sensitivity and specificity were 86.1 % and 82.5 %. For the SD of the elasticity, the Az was 0.944; with a cutoff point of 12.1, sensitivity and specificity were 88.9 % and 89.7 %. The colour overlay features showed significant correlations with the quantitative SD of the elasticity (P < 0.001). The colour overlay features and the SD of the elasticity in SWE showed excellent diagnostic performance and showed good correlations between them.

  6. Metal artifact suppression at the hip: diagnostic performance at 3.0 T versus 1.5 Tesla

    International Nuclear Information System (INIS)

    Nardo, Lorenzo; Han, Misung; Kretschmar, Martin; Krug, Roland; Link, Thomas M.; Guindani, Michele; Koch, Kevin; Vail, Thomas

    2015-01-01

    This work aimed to compare the diagnostic performance of a metal artifact suppression sequence (MAVRIC-SL) for imaging of hip arthroplasties (HA) at 1.5 and 3 Tesla (T) field strength. Eighteen patients (10 females; aged 27-74) with HA were examined at 3.0 and 1.5 T within 3 weeks. The sequence protocol included 3D-MAVRIC-SL PD (coronal), 3D-MAVRIC-SL STIR (axial), FSE T1, FSE PD and STIR sequences. Anatomical structures and pathological findings were assessed independently by two radiologists. Artifact extent and technical quality (image quality, fat saturation and geometric distortion) were also evaluated. Findings at 1.5 and 3.0 T were compared using a Wilcoxon signed rank test. While image quality was better at 1.5 T, visualization of anatomic structures and clinical abnormalities was not significantly different using the two field strengths (p > 0.05). Fat suppression and amount of artifacts were significantly better at 1.5 T (p < 0.01). Inter- and intra-reader agreement for different anatomic details, image quality and visualization of abnormalities ranged from k = 0.62 to k = 1.00. MAVRIC-SL at 1.5 T had a comparable diagnostic performance when compared MAVRIC-SL at 3.0 T; however, the higher field strength was associated with larger artifacts, limited image quality and worse fat saturation. (orig.)

  7. Diagnostic performance of PET/MR in the evaluation of active inflammation in Crohn disease.

    Science.gov (United States)

    Catalano, Onofrio Antonio; Wu, Vincent; Mahmood, Umar; Signore, Alberto; Vangel, Mark; Soricelli, Andrea; Salvatore, Marco; Gervais, Debra; Rosen, Bruce R

    2018-01-01

    This study investigates the performance of PET/MR versus each sub-modality alone in the assessment of active inflammation in patients with Crohn disease, when compared to surgery as standard of reference. Sensitivity for detecting active inflammation was 91.5% for PET, 80% for MR, and 88% for PET/MR. Specificity for active inflammation was 74% for PET, 87% for MR, and 93% for PET/MR. Diagnostic accuracy was 84% for PET, 83% for MR, and 91% for PET/MR. In conclusion, PET/MR is significantly more accurate than either sub-modality alone and more specific than PET alone in the detection of active inflammation in patients with Crohn disease.

  8. HIV misdiagnosis in sub-Saharan Africa: performance of diagnostic algorithms at six testing sites

    Science.gov (United States)

    Kosack, Cara S.; Shanks, Leslie; Beelaert, Greet; Benson, Tumwesigye; Savane, Aboubacar; Ng’ang’a, Anne; Andre, Bita; Zahinda, Jean-Paul BN; Fransen, Katrien; Page, Anne-Laure

    2017-01-01

    Abstract Introduction: We evaluated the diagnostic accuracy of HIV testing algorithms at six programmes in five sub-Saharan African countries. Methods: In this prospective multisite diagnostic evaluation study (Conakry, Guinea; Kitgum, Uganda; Arua, Uganda; Homa Bay, Kenya; Doula, Cameroun and Baraka, Democratic Republic of Congo), samples from clients (greater than equal to five years of age) testing for HIV were collected and compared to a state-of-the-art algorithm from the AIDS reference laboratory at the Institute of Tropical Medicine, Belgium. The reference algorithm consisted of an enzyme-linked immuno-sorbent assay, a line-immunoassay, a single antigen-enzyme immunoassay and a DNA polymerase chain reaction test. Results: Between August 2011 and January 2015, over 14,000 clients were tested for HIV at 6 HIV counselling and testing sites. Of those, 2786 (median age: 30; 38.1% males) were included in the study. Sensitivity of the testing algorithms ranged from 89.5% in Arua to 100% in Douala and Conakry, while specificity ranged from 98.3% in Doula to 100% in Conakry. Overall, 24 (0.9%) clients, and as many as 8 per site (1.7%), were misdiagnosed, with 16 false-positive and 8 false-negative results. Six false-negative specimens were retested with the on-site algorithm on the same sample and were found to be positive. Conversely, 13 false-positive specimens were retested: 8 remained false-positive with the on-site algorithm. Conclusions: The performance of algorithms at several sites failed to meet expectations and thresholds set by the World Health Organization, with unacceptably high rates of false results. Alongside the careful selection of rapid diagnostic tests and the validation of algorithms, strictly observing correct procedures can reduce the risk of false results. In the meantime, to identify false-positive diagnoses at initial testing, patients should be retested upon initiating antiretroviral therapy. PMID:28691437

  9. Novette diagnostic support. Final report

    International Nuclear Information System (INIS)

    Cirigliano, R.; Franco, E.; Koppel, L.; Rodrigues, B.; Smith, J.

    1985-02-01

    The primary research areas were the following: (1) contribute x-ray diagnostic, experimental, and data reduction and analysis support for the Novette DANTE x-ray spectrometer experiments. This effort was expanded to improve the overall quality of the Novette database; (2) experimental and calculational characterization of the x-ray imaging properties of an ellipsoidal x-ray collection optic serving as a sensitivity enhancing component of the Transmission Grating Streak Spectrometer; (3) performance simulation of the x-ray dispersion properties of candidate x-ray laser cavity, normal incidence end-mirror optics; (4) contribute x-ray diagnostic, experimental, and data reduction and analysis support for the Novette Henway crystal spectrometer and the MCPIGS microchannel plate intensified grazing incident spectrometer experiments; and (5) perform a technical performance vs cost evaluation of commercially available hardware required to perform the NOVA neutron time-of-flight experiments

  10. Cost Control and Performance Review of Software Projects by Using the Earned Value Management

    Directory of Open Access Journals (Sweden)

    Felician ALECU

    2014-08-01

    Full Text Available EVM (Earned Value Management is a method that can be successfully used to measure the performance of a project from the cost and schedule points of view. Initially developed for the US government programs in the 60s, it later becomes an important feature of any modern project management practice thanks to its simplicity and efficiency in signaling project anomalies in time. EVM become extremely popular because it can be equally applied for any project in any industry.

  11. Aircraft Electrical Power System Diagnostics and Health Management, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — The objective of the project is the development of an open architecture, computational toolbox for design and implementation of diagnostic and prognostic algorithms...

  12. Aircraft Electrical Power System Diagnostics and Health Management, Phase II

    Data.gov (United States)

    National Aeronautics and Space Administration — The objective of the project is the development of an open architecture, computational toolbox for design and implementation of diagnostic and prognostic algorithms...

  13. Diagnostic Performance of Computed Tomography Colonography and Colonoscopy: A Prospective and Validated Analysis of 231 Paired Examinations

    International Nuclear Information System (INIS)

    Arnesen, R.B.; Benzon, E. von; Adamsen, S.; Svendsen, L.B.; Raaschou, H.O.; Hart Hansen, O.

    2007-01-01

    Background: Detection of colorectal tumors with computed tomography colonography (CTC) is an alternative to conventional colonoscopy (CC), and clarification of the diagnostic performance is essential for cost-effective use of both technologies. Purpose: To evaluate the diagnostic performance of CTC compared with CC. Material and Methods: 231 consecutive CTCs were performed prior to same-day scheduled CC. The radiologist and endoscopists were blinded to each other's findings. Patients underwent a polyethylene glycol bowel preparation, and were scanned in prone and supine positions using a single-detector helical CT scanner and commercially available software for image analysis. Findings were validated (matched) in an unblinded comparison with video-recordings of the CCs and re-CCs in cases of doubt. Results: For patients with polyps 5 mm and 10 mm, the sensitivity was 69% (95% CI 58-80%) and 81% (68-94%), and the specificity was 91% (84-98%) and 98% (93-100%), respectively. For detection of polyps 5 mm and 10 mm, the sensitivity was 66% (57-75%) and 77% (65-89%). A flat, elevated low-grade carcinoma was missed by CTC. One cancer relapse was missed by CC, and a cecal cancer was missed by an incomplete CC and follow-up double-contrast barium enema. Conclusion: CC was superior to CTC and should remain first choice for the diagnosis of colorectal polyps. However, for diagnosis of lesions 10 mm, CTC and CC should be considered as complementary methods

  14. Documenting cost and performance for environmental remediation projects: Department of Energy Office of Environmental Management

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1996-08-08

    The purpose of this DOE guide is to facilitate the use of consistent procedures to document cost and performance information for projects involving the remediation of media contaminated with hazardous and radioactive wastes. It provides remedial action project managers with a standardized set of data to document completed remediation projects. Standardized reporting of data will broaden the utility of the information, increase confidence in the effectiveness of future remedial technologies, and enhance the organization, storage and retrieval of relevant information for future cleanup projects. The foundation for this guide was laid down by the Federal Remediation Technologies Roundtable (FRTR) in their publication, Guide to Documenting Cost and Performance for Remediation Projects, EPA-542-B- 95-002. Member agencies of the FRTR include the US EPA, the US DOD, the US DOE, and the US DOI. All the member agencies are involved in site remediation projects and anticipate following the guidance provided in the above reference. Therefore, there is much to be gained for DOE to be consistent with the other member agencies as it will be easier to compare projects across different agencies and also to learn from the experiences of a wider spectrum of prior completed projects.

  15. Systematic Benchmarking of Diagnostic Technologies for an Electrical Power System

    Science.gov (United States)

    Kurtoglu, Tolga; Jensen, David; Poll, Scott

    2009-01-01

    Automated health management is a critical functionality for complex aerospace systems. A wide variety of diagnostic algorithms have been developed to address this technical challenge. Unfortunately, the lack of support to perform large-scale V&V (verification and validation) of diagnostic technologies continues to create barriers to effective development and deployment of such algorithms for aerospace vehicles. In this paper, we describe a formal framework developed for benchmarking of diagnostic technologies. The diagnosed system is the Advanced Diagnostics and Prognostics Testbed (ADAPT), a real-world electrical power system (EPS), developed and maintained at the NASA Ames Research Center. The benchmarking approach provides a systematic, empirical basis to the testing of diagnostic software and is used to provide performance assessment for different diagnostic algorithms.

  16. Measuring the effect of e-business on organizational performance in project based organizations

    Directory of Open Access Journals (Sweden)

    Soheil Sadi-Nezhad

    2017-12-01

    Full Text Available Recently, there have been significant development on e-business and nearly all business partners try to offer their products and services via internet. One primary question for the implementation of e-business is to measure the effect of this new facility on supply chain in project based organizations. Although e-business may not directly influence on organizational performance, it definitely influences on unifying customers and suppliers, which yields to a better performance of organizations. This study performs a study to measure the indirect effect of e-business on project based organizational performance. The proposed study of this paper designs a questionnaire and distributes it among 140 professional experts in different industries in province of Ontario, Canada. The survey examines different hypotheses for a possible correlation between e-business and integrated suppliers, e-business and customers, integrated customers and suppliers with organizational performance. The results of this survey indicate a positive relationship between all these components either directly or indirectly.

  17. Catalysing progressive uptake of newer diagnostics by health care providers through outreach and education in four major cities of India.

    Directory of Open Access Journals (Sweden)

    Neeraj Raizada

    Full Text Available Unlike in adults, diagnosis of TB can be challenging in children, as signs and symptoms of paediatric TB can be very non-specific and similar to other common childhood chest infections, which may lead to under or delayed diagnosis of TB disease. In spite of the increasing availability of rapid high-sensitivity diagnostics in public and private sectors, majority of paediatric TB cases are empirically diagnosed, without laboratory confirmation. To address these diagnostic challenges, World Health Organization (WHO has recommended upfront Xpert MTB/RIF (Xpert testing for the diagnosis of TB in paediatric presumptive pulmonary and extra-pulmonary TB (EPTB cases. However, in spite of the increasing availability of rapid high-sensitivity diagnostics, a significant gap exists in its application with Xpert being rarely used as an upfront diagnostic among patients presumed to have TB. Under an ongoing paediatric project since April 2014, which provided free-of-cost upfront Xpert testing, several low-cost outreach and education interventions were undertaken to increase the diagnostic uptake by different providers catering to the paediatric population, thereby increasing adherence to global guidance.Providers catering to paediatric population in the project cities were systematically mapped and contacted using different outreach strategies. The focus of outreach efforts was to increase provider literacy and increase their awareness of the availability of free rapid diagnostic services with the goal of changing their diagnostic approaches.From April 2014 to June 2016, more than 5,700 providers/facilities were mapped and 3,670 of them were approached. The number of providers/facilities engaged under the project increased more than 10-fold (43 in April, 2014 to 466 in June, 2016, with significant increase in project uptake, both from public and private sector. Overall 42,238 paediatric presumptive TB cases were enrolled in the project, across the four cities

  18. Diagnostic reasoning strategies and diagnostic success.

    Science.gov (United States)

    Coderre, S; Mandin, H; Harasym, P H; Fick, G H

    2003-08-01

    Cognitive psychology research supports the notion that experts use mental frameworks or "schemes", both to organize knowledge in memory and to solve clinical problems. The central purpose of this study was to determine the relationship between problem-solving strategies and the likelihood of diagnostic success. Think-aloud protocols were collected to determine the diagnostic reasoning used by experts and non-experts when attempting to diagnose clinical presentations in gastroenterology. Using logistic regression analysis, the study found that there is a relationship between diagnostic reasoning strategy and the likelihood of diagnostic success. Compared to hypothetico-deductive reasoning, the odds of diagnostic success were significantly greater when subjects used the diagnostic strategies of pattern recognition and scheme-inductive reasoning. Two other factors emerged as independent determinants of diagnostic success: expertise and clinical presentation. Not surprisingly, experts outperformed novices, while the content area of the clinical cases in each of the four clinical presentations demonstrated varying degrees of difficulty and thus diagnostic success. These findings have significant implications for medical educators. It supports the introduction of "schemes" as a means of enhancing memory organization and improving diagnostic success.

  19. Performance of Different Diagnostic Criteria for Familial Mediterranean Fever in Children with Periodic Fevers : Results from a Multicenter International Registry

    NARCIS (Netherlands)

    Demirkaya, Erkan; Saglam, Celal; Turker, Turker; Koné-Paut, Isabelle; Woo, Pat; Doglio, Matteo; Amaryan, Gayane; Frenkel, Joost; Uziel, Yosef; Insalaco, Antonella; Cantarini, Luca; Hofer, Michael; Boiu, Sorina; Duzova, Ali; Modesto, Consuelo; Bryant, Annette; Rigante, Donato; Papadopoulou-Alataki, Efimia; Guillaume-Czitrom, Severine; Kuemmerle-Deschner, Jasmine; Neven, Bénédicte; Lachmann, Helen; Martini, Alberto; Ruperto, Nicolino; Gattorno, Marco; Ozen, Seza

    2015-01-01

    OBJECTIVE: Our aims were to validate the pediatric diagnostic criteria in a large international registry and to compare them with the performance of previous criteria for the diagnosis of familial Mediterranean fever (FMF). METHODS: Pediatric patients with FMF from the Eurofever registry were used

  20. Case-based reasoning combined with statistics for diagnostics and prognosis

    International Nuclear Information System (INIS)

    Olsson, T; Funk, P

    2012-01-01

    Many approaches used for diagnostics today are based on a precise model. This excludes diagnostics of many complex types of machinery that cannot be modelled and simulated easily or without great effort. Our aim is to show that by including human experience it is possible to diagnose complex machinery when there is no or limited models or simulations available. This also enables diagnostics in a dynamic application where conditions change and new cases are often added. In fact every new solved case increases the diagnostic power of the system. We present a number of successful projects where we have used feature extraction together with case-based reasoning to diagnose faults in industrial robots, welding, cutting machinery and we also present our latest project for diagnosing transmissions by combining Case-Based Reasoning (CBR) with statistics. We view the fault diagnosis process as three consecutive steps. In the first step, sensor fault signals from machines and/or input from human operators are collected. Then, the second step consists of extracting relevant fault features. In the final diagnosis/prognosis step, status and faults are identified and classified. We view prognosis as a special case of diagnosis where the prognosis module predicts a stream of future features.

  1. Clinical and Demographic Stratification of Test Performance: A Pooled Analysis of Five Laboratory Diagnostic Methods for American Cutaneous Leishmaniasis

    Science.gov (United States)

    Boggild, Andrea K.; Ramos, Ana P.; Espinosa, Diego; Valencia, Braulio M.; Veland, Nicolas; Miranda-Verastegui, Cesar; Arevalo, Jorge; Low, Donald E.; Llanos-Cuentas, Alejandro

    2010-01-01

    We evaluated performance characteristics of five diagnostic methods for cutaneous leishmaniasis. Patients who came to the Leishmania Clinic of Hospital Nacional Cayetano Heredia in Lima, Peru, were enrolled in the study. Lesion smears, culture, microculture, polymerase chain reaction (PCR), and leishmanin skin test (LST) were performed. A total of 145 patients with 202 lesions were enrolled: 114 patients with 161 lesions fulfilled criteria for cutaneous leishmaniasis. Sensitivity and specificity were 57.8% (95% confidence interval [CI] = 50.2–65.4%) and 100.0% for culture, 78.3% (95% CI = 71.9–84.7%) and 100.0% for microculture, 71.4% (95% CI = 64.4–78.4%) and 100.0% for smears, 78.2% (95% CI = 70.6–85.8%) and 77.4% (95% CI = 62.7–92.1%) for LST, and 96.9% (95% CI = 94.2–99.6%) and 65.9% (95% CI = 51.4–80.4%) for PCR. PCR was more sensitive than the other assays (P < 0.001). Sensitivities of culture, smears, and LST varied by lesion duration and appearance. PCR offers performance advantages over other assays, irrespective of patient age, sex, lesion duration, or appearance. That clinical factors influence performance of non-molecular assays offers clinicians a patient-focused approach to diagnostic test selection. PMID:20682880

  2. Comparative guide to emerging diagnostic tools for large commercial HVAC systems

    Energy Technology Data Exchange (ETDEWEB)

    Friedman, Hannah; Piette, Mary Ann

    2001-05-01

    This guide compares emerging diagnostic software tools that aid detection and diagnosis of operational problems for large HVAC systems. We have evaluated six tools for use with energy management control system (EMCS) or other monitoring data. The diagnostic tools summarize relevant performance metrics, display plots for manual analysis, and perform automated diagnostic procedures. Our comparative analysis presents nine summary tables with supporting explanatory text and includes sample diagnostic screens for each tool.

  3. Gonad protection for the antero-posterior projection of the pelvis in diagnostic radiography in Dublin hospitals

    Energy Technology Data Exchange (ETDEWEB)

    Doolan, Aoife; Brennan, Patrick C. E-mail: patrick.brennan@ucd.ie; Rainford, Louise A.; Healy, Jan

    2004-02-01

    Gonad shielding during diagnostic X-ray procedures is an effective way of reducing radiation dose to patients' reproductive organs and reduces the risk of genetic effects in future generations. The utilisation of gonad shielding, the availability of shields and the existence of written protocols for the use of radiation shielding for antero-posterior projections of the male and female pelvis were examined in four major Dublin hospitals. A retrospective study of 198 pelvic radiographs revealed that only 2% (n=4) of images had evidence of gonad shielding. All four images that demonstrated shielding showed that the shield was malpositioned with either important bony anatomy obscured or gonads not sufficiently protected. Some of the hospitals surveyed had inadequate supplies of gonad shields in the general radiography rooms and no written protocols were available. The results of this study indicate that patients in the hospitals investigated are receiving avoidable gonad irradiation due to the omission, or malpositioning of gonad shields during pelvis examinations. In line with recent EC recommendations appropriate shielding of the gonads during pelvis AP examinations should be encouraged.

  4. Gonad protection for the antero-posterior projection of the pelvis in diagnostic radiography in Dublin hospitals

    International Nuclear Information System (INIS)

    Doolan, Aoife; Brennan, Patrick C.; Rainford, Louise A.; Healy, Jan

    2004-01-01

    Gonad shielding during diagnostic X-ray procedures is an effective way of reducing radiation dose to patients' reproductive organs and reduces the risk of genetic effects in future generations. The utilisation of gonad shielding, the availability of shields and the existence of written protocols for the use of radiation shielding for antero-posterior projections of the male and female pelvis were examined in four major Dublin hospitals. A retrospective study of 198 pelvic radiographs revealed that only 2% (n=4) of images had evidence of gonad shielding. All four images that demonstrated shielding showed that the shield was malpositioned with either important bony anatomy obscured or gonads not sufficiently protected. Some of the hospitals surveyed had inadequate supplies of gonad shields in the general radiography rooms and no written protocols were available. The results of this study indicate that patients in the hospitals investigated are receiving avoidable gonad irradiation due to the omission, or malpositioning of gonad shields during pelvis examinations. In line with recent EC recommendations appropriate shielding of the gonads during pelvis AP examinations should be encouraged

  5. The DAG project, a 4m class telescope: the telescope main structure performances

    Science.gov (United States)

    Marchiori, G.; Busatta, A.; Ghedin, L.; Marcuzzi, E.; Manfrin, C.; Battistel, C.; Pirnay, O.; Flebus, Carlo; Yeşilyaprak, C.; Keskin, O.; Yerli, S.

    2016-07-01

    Dogu Anatolu Gözlemevi (DAG-Eastern Anatolia Observatory) Project is a 4m class optical, near-infrared Telescope and suitable enclosure which will be located at an altitude of 3.170m in Erzurum, Turkey. The DAG telescope is a project fully funded by Turkish Ministry of Development and the Atatürk University of Astrophysics Research Telescope - ATASAM. The Project is being developed by the Belgian company AMOS (project leader), which is also the optics supplier and EIE GROUP, the Telescope Main Structure supplier and responsible for the final site integration. The design of the Telescope Main Structure fits in the EIE TBO Program which aims at developing a Dome/Telescope systemic optimization process for both performances and competitive costs based on previous project commitments like NTT, VLT, VST and ASTRI. The optical Configuration of the DAG Telescope is a Ritchey-Chretien with two Nasmyth foci and a 4m primary thin mirror controlled in shape and position by an Active Optic System. The main characteristics of the Telescope Main Structure are an Altitude-Azimuth light and rigid structure system with Direct Drive Systems for both axis, AZ Hydrostatic Bearing System and Altitude standard bearing system; both axes are equipped with Tape Encoder System. An innovative Control System characterizes the telescope performance.

  6. Application of Supply Chain Performance Measurement in Scor Model at Building Project

    OpenAIRE

    Wibowo, Mochamad Agung; Sholeh, Moh Nur

    2016-01-01

    The supply chain has become a priority subject of management research and manufacturing theory in recent years. It has also become an interesting topic in the construction industry. Construction supply chain management is more concerned with the coordination of discrete quantities of materials delivered to a specific construction project. Currently, in some building project, there has been no standard indicators in measuring the performance of the supply chain. Therefore, further research is ...

  7. CT fluoroscopy-guided renal tumour cutting needle biopsy. Retrospective evaluation of diagnostic yield, safety, and risk factors for diagnostic failure

    International Nuclear Information System (INIS)

    Iguchi, Toshihiro; Hiraki, Takao; Matsui, Yusuke; Fujiwara, Hiroyasu; Sakurai, Jun; Masaoka, Yoshihisa; Gobara, Hideo; Kanazawa, Susumu

    2018-01-01

    To evaluate retrospectively the diagnostic yield, safety, and risk factors for diagnostic failure of computed tomography (CT) fluoroscopy-guided renal tumour biopsy. Biopsies were performed for 208 tumours (mean diameter 2.3 cm; median diameter 2.1 cm; range 0.9-8.5 cm) in 199 patients. One hundred and ninety-nine tumours were ≤4 cm. All 208 initial procedures were divided into diagnostic success and failure groups. Multiple variables related to the patients, lesions, and procedures were assessed to determine the risk factors for diagnostic failure. After performing 208 initial and nine repeat biopsies, 180 malignancies and 15 benign tumours were pathologically diagnosed, whereas 13 were not diagnosed. In 117 procedures, 118 Grade I and one Grade IIIa adverse events (AEs) occurred. Neither Grade ≥IIIb AEs nor tumour seeding were observed within a median follow-up period of 13.7 months. Logistic regression analysis revealed only small tumour size (≤1.5 cm; odds ratio 3.750; 95% confidence interval 1.362-10.326; P = 0.011) to be a significant risk factor for diagnostic failure. CT fluoroscopy-guided renal tumour biopsy is a safe procedure with a high diagnostic yield. A small tumour size (≤1.5 cm) is a significant risk factor for diagnostic failure. (orig.)

  8. CT fluoroscopy-guided renal tumour cutting needle biopsy. Retrospective evaluation of diagnostic yield, safety, and risk factors for diagnostic failure

    Energy Technology Data Exchange (ETDEWEB)

    Iguchi, Toshihiro; Hiraki, Takao; Matsui, Yusuke; Fujiwara, Hiroyasu; Sakurai, Jun; Masaoka, Yoshihisa; Gobara, Hideo; Kanazawa, Susumu [Okayama University Medical School, Department of Radiology, Okayama (Japan)

    2018-01-15

    To evaluate retrospectively the diagnostic yield, safety, and risk factors for diagnostic failure of computed tomography (CT) fluoroscopy-guided renal tumour biopsy. Biopsies were performed for 208 tumours (mean diameter 2.3 cm; median diameter 2.1 cm; range 0.9-8.5 cm) in 199 patients. One hundred and ninety-nine tumours were ≤4 cm. All 208 initial procedures were divided into diagnostic success and failure groups. Multiple variables related to the patients, lesions, and procedures were assessed to determine the risk factors for diagnostic failure. After performing 208 initial and nine repeat biopsies, 180 malignancies and 15 benign tumours were pathologically diagnosed, whereas 13 were not diagnosed. In 117 procedures, 118 Grade I and one Grade IIIa adverse events (AEs) occurred. Neither Grade ≥IIIb AEs nor tumour seeding were observed within a median follow-up period of 13.7 months. Logistic regression analysis revealed only small tumour size (≤1.5 cm; odds ratio 3.750; 95% confidence interval 1.362-10.326; P = 0.011) to be a significant risk factor for diagnostic failure. CT fluoroscopy-guided renal tumour biopsy is a safe procedure with a high diagnostic yield. A small tumour size (≤1.5 cm) is a significant risk factor for diagnostic failure. (orig.)

  9. Data processing technologies and diagnostics for water chemistry and corrosion control in nuclear power plants (DAWAC). Report of a coordinated research project 2001-2005

    International Nuclear Information System (INIS)

    2006-06-01

    This publication provides information on the current status and development trends in monitoring, diagnostics and control of water chemistry and corrosion of core and primary circuit materials in water cooled power reactors. It summarizes the results of an IAEA Coordinated Research Project and focuses on the methods for development, qualification and implementation of water chemistry expert systems at nuclear power plants. These systems are needed to have full benefit from using on-line sensors in real time mode when sensor signals, and other chemistry and operational data, are collected and continuously analysed with data acquisition and evaluation software. Technical knowledge was acquired in water chemistry control techniques (grab sampling, on-line monitoring, data collecting and processing, etc), plant chemistry and corrosion diagnostics, plant monitoring (corrosion, chemistry, activity) and plant chemistry improvement (analytical models and practices). This publication covers contributions from leading experts in water chemistry/corrosion, representing organizations from 16 countries with the largest nuclear capacities

  10. Reference moderator calculated performance for the LANSCE upgrade project

    International Nuclear Information System (INIS)

    Ferguson, P.D.; Russell, G.J.; Pitcher, E.J.

    1995-01-01

    The authors have calculated the performance of five moderators of interest to the LANSCE upgrade project. Coupled and decoupled light water and liquid hydrogen moderators in flux-trap geometry surrounded by a neutronically infinite heavy-water cooled beryllium reflector have been studied. Time and energy spectra, as well as semi-empirical fits to the data, are presented. The data has been made available to aid the instrument design and moderator selection process

  11. Multigigahertz beam diagnostics for laser fusion

    International Nuclear Information System (INIS)

    Smith, R.C.; Hodson, E.K.; Carlson, R.L.

    1981-01-01

    A system to make ultra wideband measurements of fast laser pulses and their induced target interactions at a distance of approximately 38 m from the target location is discussed. The system has demonstrated an overall bandwidth of 3 GHz with projected unfolding to 4 GHz. This system allows high resolution temporal history diagnostics in a remote location providing high EMI and radiation immunity

  12. Diagnostic performance of whole brain volume perfusion CT in intra-axial brain tumors: Preoperative classification accuracy and histopathologic correlation

    International Nuclear Information System (INIS)

    Xyda, Argyro; Haberland, Ulrike; Klotz, Ernst; Jung, Klaus; Bock, Hans Christoph; Schramm, Ramona; Knauth, Michael; Schramm, Peter

    2012-01-01

    Background: To evaluate the preoperative diagnostic power and classification accuracy of perfusion parameters derived from whole brain volume perfusion CT (VPCT) in patients with cerebral tumors. Methods: Sixty-three patients (31 male, 32 female; mean age 55.6 ± 13.9 years), with MRI findings suspected of cerebral lesions, underwent VPCT. Two readers independently evaluated VPCT data. Volumes of interest (VOIs) were marked circumscript around the tumor according to maximum intensity projection volumes, and then mapped automatically onto the cerebral blood volume (CBV), flow (CBF) and permeability Ktrans perfusion datasets. A second VOI was placed in the contra lateral cortex, as control. Correlations among perfusion values, tumor grade, cerebral hemisphere and VOIs were evaluated. Moreover, the diagnostic power of VPCT parameters, by means of positive and negative predictive value, was analyzed. Results: Our cohort included 32 high-grade gliomas WHO III/IV, 18 low-grade I/II, 6 primary cerebral lymphomas, 4 metastases and 3 tumor-like lesions. Ktrans demonstrated the highest sensitivity, specificity and positive predictive value, with a cut-off point of 2.21 mL/100 mL/min, for both the comparisons between high-grade versus low-grade and low-grade versus primary cerebral lymphomas. However, for the differentiation between high-grade and primary cerebral lymphomas, CBF and CBV proved to have 100% specificity and 100% positive predictive value, identifying preoperatively all the histopathologically proven high-grade gliomas. Conclusion: Volumetric perfusion data enable the hemodynamic assessment of the entire tumor extent and provide a method of preoperative differentiation among intra-axial cerebral tumors with promising diagnostic accuracy.

  13. Diagnostic value of performing endocervical curettage at the time of colposcopy procedure; a systematic review

    Directory of Open Access Journals (Sweden)

    Shabnam Imannezhad

    2016-03-01

    Full Text Available Introduction: The importance of high-grade cervical intraepithelial neoplasia (CIN as a precursor to invasive cervical cancer suggests a considerable need for accurate screening of the patients for the risk of these lesions. This systematic review aimed to study the diagnostic significance of endocervical curettage (ECC at the time of colposcopy in the detection of CIN 2, 3, and preinvasive lesions.Methods: PubMed was searched to obtain the relevant articles based on the following search term: (endocervical curettage OR ECC AND colposcopy. The most relevant articles were included after studying the title, abstract, and full text of the obtained articles at initial search. Only English language articles published after 1992 with at least 500 patients were included in this study.Result: Among 300 articles identified by the first search, only seven articles were in line with the purpose of this systematic review. Majority of the included studies were retrospective observational studies.Conclusion: Performing ECC has higher sensitivity in women older than 40 years and those with unsatisfactory colposcopy results. However exact diagnostic usefulness of ECC at the time of colposcopy needs to be investigated in further studies.

  14. Diagnostic performance of serological tests to detect antibodies against acute scrub typhus infection in central India

    Directory of Open Access Journals (Sweden)

    Kiran Pote

    2018-01-01

    Full Text Available Background: Differentiating scrub typhus from other acute febrile illness is difficult due to non specificity of clinical symptoms and relative absence of eschar in Indian population. The diagnosis thus relies mainly on laboratory tests. Antibody based serological tests are mainstay of scrub typhus diagnosis. Here, we evaluated the diagnostic performance of IgM ELISA, IgM IFA and ICT to detect antibodies against O. tsutsugamushi in acute serum of febrile patients. Methodology: The serum samples from 600 randomly selected patients suffering from acute undifferentiated fever were tested by all the three tests mentioned above. We used latent class analysis to generate unbiased results as all the tests for scrub typhus diagnosis are imperfect and none of them can be considered as reference standard. Results: We found that IgM ELISA with cutoff titer 0.5 OD has high diagnostic accuracy (sensitivity 99.9% and specificity 99.15 than IgM IFA (sensitivity 96.8% and specificity 99.7% for scrub typhus diagnosis. ICT used in our study had very high specificity 100% but low sensitivity (38% which would limit its use for acute serum samples. ICT being a screening or point of care test, has to be more sensitive while some compromise with specificity is affordable. Hence, optimal cutoff for ICT should be evaluated under different settings. Conclusion: IgM ELISA being simple and affordable could be an alternative diagnostic test to IgM IFA which is subjective and costly.

  15. Diagnostic performance of serological tests to detect antibodies against acute scrub typhus infection in central India.

    Science.gov (United States)

    Pote, Kiran; Narang, Rahul; Deshmukh, Pradeep

    2018-01-01

    Differentiating scrub typhus from other acute febrile illness is difficult due to non specificity of clinical symptoms and relative absence of eschar in Indian population. The diagnosis thus relies mainly on laboratory tests. Antibody based serological tests are mainstay of scrub typhus diagnosis. Here, we evaluated the diagnostic performance of IgM ELISA, IgM IFA and ICT to detect antibodies against O. tsutsugamushi in acute serum of febrile patients. The serum samples from 600 randomly selected patients suffering from acute undifferentiated fever were tested by all the three tests mentioned above. We used latent class analysis to generate unbiased results as all the tests for scrub typhus diagnosis are imperfect and none of them can be considered as reference standard. We found that IgM ELISA with cutoff titer 0.5 OD has high diagnostic accuracy (sensitivity 99.9% and specificity 99.15) than IgM IFA (sensitivity 96.8% and specificity 99.7%) for scrub typhus diagnosis. ICT used in our study had very high specificity 100% but low sensitivity (38%) which would limit its use for acute serum samples. ICT being a screening or point of care test, has to be more sensitive while some compromise with specificity is affordable. Hence, optimal cutoff for ICT should be evaluated under different settings. IgM ELISA being simple and affordable could be an alternative diagnostic test to IgM IFA which is subjective and costly.

  16. The use of roentgen diagnostics in chiropractor activities. Project based survey according to new regulations regarding radiation protection and use of radiation

    International Nuclear Information System (INIS)

    Raaum, Aud; Widmark, Anders

    2005-12-01

    An audit has been performed in 17 chiropractic enterprises according to new radiation protection legislation. Before the audits a survey of the use of diagnostic imaging in Norwegian chiropractic enterprises was carried out. This report summarizes the results of the survey and the findings at the audits. (Author)

  17. Diagnostic Impact and Cost-effectiveness of Whole-Exome Sequencing for Ambulant Children With Suspected Monogenic Conditions.

    Science.gov (United States)

    Tan, Tiong Yang; Dillon, Oliver James; Stark, Zornitza; Schofield, Deborah; Alam, Khurshid; Shrestha, Rupendra; Chong, Belinda; Phelan, Dean; Brett, Gemma R; Creed, Emma; Jarmolowicz, Anna; Yap, Patrick; Walsh, Maie; Downie, Lilian; Amor, David J; Savarirayan, Ravi; McGillivray, George; Yeung, Alison; Peters, Heidi; Robertson, Susan J; Robinson, Aaron J; Macciocca, Ivan; Sadedin, Simon; Bell, Katrina; Oshlack, Alicia; Georgeson, Peter; Thorne, Natalie; Gaff, Clara; White, Susan M

    2017-09-01

    Optimal use of whole-exome sequencing (WES) in the pediatric setting requires an understanding of who should be considered for testing and when it should be performed to maximize clinical utility and cost-effectiveness. To investigate the impact of WES in sequencing-naive children suspected of having a monogenic disorder and evaluate its cost-effectiveness if WES had been available at different time points in their diagnostic trajectory. This prospective study was part of the Melbourne Genomics Health Alliance demonstration project. At the ambulatory outpatient clinics of the Victorian Clinical Genetics Services at the Royal Children's Hospital, Melbourne, Australia, children older than 2 years suspected of having a monogenic disorder were prospectively recruited from May 1 through November 30, 2015, by clinical geneticists after referral from general and subspecialist pediatricians. All children had nondiagnostic microarrays and no prior single-gene or panel sequencing. All children underwent singleton WES with targeted phenotype-driven analysis. The study examined the clinical utility of a molecular diagnosis and the cost-effectiveness of alternative diagnostic trajectories, depending on timing of WES. Of 61 children originally assessed, 44 (21 [48%] male and 23 [52%] female) aged 2 to 18 years (mean age at initial presentation, 28 months; range, 0-121 months) were recruited, and a diagnosis was achieved in 23 (52%) by singleton WES. The diagnoses were unexpected in 8 of 23 (35%), and clinical management was altered in 6 of 23 (26%). The mean duration of the diagnostic odyssey was 6 years, with each child having a mean of 19 tests and 4 clinical genetics and 4 nongenetics specialist consultations, and 26 (59%) underwent a procedure while under general anesthetic for diagnostic purposes. Economic analyses of the diagnostic trajectory identified that WES performed at initial tertiary presentation resulted in an incremental cost savings of A$9020 (US$6838) per

  18. Experimental Plasma Research project summaries

    International Nuclear Information System (INIS)

    1980-09-01

    This report contains descriptions of the activities supported by the Experimental Plasma Research Branch of APP. The individual project summaries were prepared by the principal investigators and include objectives and milestones for each project. The projects are arranged in six research categories: Plasma Properties; Plasma Heating; Plasma Diagnostics; Atomic, Molecular and Nuclear Physics; Advanced Superconducting Materials; and the Fusion Plasma Research Facility (FPRF). Each category is introduced with a statement of objectives and recent progress and followed by descriptions of individual projects. An overall budget summary is provided at the beginning of the report

  19. Experimental Plasma Research project summaries

    Energy Technology Data Exchange (ETDEWEB)

    None

    1980-09-01

    This report contains descriptions of the activities supported by the Experimental Plasma Research Branch of APP. The individual project summaries were prepared by the principal investigators and include objectives and milestones for each project. The projects are arranged in six research categories: Plasma Properties; Plasma Heating; Plasma Diagnostics; Atomic, Molecular and Nuclear Physics; Advanced Superconducting Materials; and the Fusion Plasma Research Facility (FPRF). Each category is introduced with a statement of objectives and recent progress and followed by descriptions of individual projects. An overall budget summary is provided at the beginning of the report.

  20. High Pressure Water Jet System Performance Assessment Project A-2A

    International Nuclear Information System (INIS)

    FARWICK, C.C.

    1999-01-01

    Performance assessment for canister cleaning system in the KE Basin. Information obtained from this assessment will be used to design any additional equipment used to clean canisters. After thorough review of the design, maintenance history and operational characteristics of the 105 K East (KE) canister cleaning system, Bartlett recommends that the high pressure water jet system (HPWJS) be modified as outlined in section 5.0, and retained for future use. Further, it is recommended that Spent Nuclear Fuel (SNF) Project consider use of a graded approach for canister cleaning, based on individual canister type and characteristics. This approach would allow a simple method to be used on canisters not needing the more rigorous, high-pressure method. Justification is provided in section 5.0. Although Bartlett has provided some preliminary cost estimates, it is recommended that SNF Project perform a detailed cost-benefit analysis to weigh the alternatives presented

  1. A project by the SIDeMaST Immunopathology Group on cutaneous vasculitis.

    Science.gov (United States)

    Papini, M; Quaglino, P; La Placa, M; Marzano, A V

    2015-04-01

    Vasculitides are a challenge to the clinician, in terms of both diagnosis and therapy. Multiple classification systems have been implemented and the numerous classification schemes reflect the complexity of establishing a simple classification that could be functional for daily care. Although vasculitis classification has become increasingly elaborated, some areas remain ill defined. Some forms of vasculitis are still difficult to assign to a specific disease entity. Generally accepted operational criteria are available for many vasculitides, but for some entities there are no effective criteria. Moreover, diagnostic criteria for vasculitis with sufficient strength and/or confidence that can be universally accepted are not yet available. The need for diagnostic criteria validated and agreed upon is particularly relevant in the context of cutaneous vasculitis. The project of the SIDeMaST Italian Group of Immunopathology on cutaneous vasculitis is a national prospective observational study designed to develop and validate diagnostic criteria and to improve and validate classification criteria for cutaneous small vessel vasculitis also known as leukocytoclastic vasculitis (CLV). Primary objective of the study will also be that of developing the CUtaneous VAsculitis Severity Index (CUVASI). Secondary objectives of the project will be: 1) definition of the etiological agents that are most frequently associated with CLV; 2) search for possible correlations between causative agent and peculiar clinical and/or histopathological aspects; 3) evaluation of immunofluorescence pattern observed in this specific group of primitive cutaneous vasculitis in order to characterize the diagnostic sensitivity and specificity of this technique; 4) identification of a set of clinical investigations and laboratory tests to be performed for a correct CLV assessment. Actually 15 Italian dermatological clinics are contributing to the project and anticipated recruiting >100 patients with CLV

  2. Performance and Pain Tolerability of Current Diagnostic Allergy Skin Prick Test Devices.

    Science.gov (United States)

    Tversky, Jody R; Chelladurai, Yohalakshmi; McGready, John; Hamilton, Robert G

    2015-01-01

    Allergen skin prick testing remains an essential tool for diagnosing atopic disease and guiding treatment. Sensitivity needs to be defined for newly introduced devices. Our aim was to compare the performance of 10 current allergy skin prick test devices. Single- and multiheaded skin test devices (n = 10) were applied by a single operator in a prospective randomized manner. Histamine (1 and 6 mg/mL) and control diluent were introduced at 6 randomized locations onto the upper and lower arms of healthy subjects. Wheal and flare reactions were measured independently by 2 masked technicians. Twenty-four subjects provided consent, and 768 skin tests were placed. Mean wheal diameter among devices differed from 3.0 mm (ComforTen; Hollister-Stier, Spokane, Wash) to 6.8 mm (UniTest PC; Lincoln Diagnostics, Decatur, Ill) using 1 mg/mL histamine (P Diagnostics, Decatur, Ill; and Sharp-Test; Panatrex, Placentia, Calif) using 6 mg/mL histamine (P pain score of less than 4 on a 10-point visual analog scale. Pain scores were higher among women, but this did not reach statistical significance. The Multi-Test PC and the UniTest PC had the lowest pain scores compared with the other devices. All 10 skin prick test devices displayed good analytical sensitivity and specificity; however, 3 mm cannot arbitrarily be used as a positive threshold. The use of histamine at 1 mg/mL is unacceptable for certain devices but may be preferable for the most sensitive devices. On average, there was no pain score difference between multiheaded and single-head devices. Copyright © 2015 American Academy of Allergy, Asthma & Immunology. Published by Elsevier Inc. All rights reserved.

  3. LEDDB : LOFAR Epoch of Reionization Diagnostic Database

    NARCIS (Netherlands)

    Martinez-Rubi, O.; Veligatla, V. K.; de Bruyn, A. G.; Lampropoulos, P.; Offringa, A. R.; Jelic, V.; Yatawatta, S.; Koopmans, L. V. E.; Zaroubi, S.

    2013-01-01

    One of the key science projects of the Low-Frequency Array (LOFAR) is the detection of the cosmological signal coming from the Epoch of Reionization (EoR). Here we present the LOFAR EoR Diagnostic Database (LEDDB) that is used in the storage, management, processing and analysis of the LOFAR EoR

  4. Application of the Systematic Sensor Selection Strategy for Turbofan Engine Diagnostics

    Science.gov (United States)

    Sowers, T. Shane; Kopasakis, George; Simon, Donald L.

    2008-01-01

    The data acquired from available system sensors forms the foundation upon which any health management system is based, and the available sensor suite directly impacts the overall diagnostic performance that can be achieved. While additional sensors may provide improved fault diagnostic performance, there are other factors that also need to be considered such as instrumentation cost, weight, and reliability. A systematic sensor selection approach is desired to perform sensor selection from a holistic system-level perspective as opposed to performing decisions in an ad hoc or heuristic fashion. The Systematic Sensor Selection Strategy is a methodology that optimally selects a sensor suite from a pool of sensors based on the system fault diagnostic approach, with the ability of taking cost, weight, and reliability into consideration. This procedure was applied to a large commercial turbofan engine simulation. In this initial study, sensor suites tailored for improved diagnostic performance are constructed from a prescribed collection of candidate sensors. The diagnostic performance of the best performing sensor suites in terms of fault detection and identification are demonstrated, with a discussion of the results and implications for future research.

  5. Diagnostic performance of quantitative shear wave elastography in the evaluation of solid breast masses: determination of the most discriminatory parameter.

    Science.gov (United States)

    Au, Frederick Wing-Fai; Ghai, Sandeep; Moshonov, Hadas; Kahn, Harriette; Brennan, Cressida; Dua, Hemi; Crystal, Pavel

    2014-09-01

    The purpose of this article is to assess the diagnostic performance of quantitative shear wave elastography in the evaluation of solid breast masses and to determine the most discriminatory parameter. B-mode ultrasound and shear wave elastography were performed before core biopsy of 123 masses in 112 women. The diagnostic performance of ultrasound and quantitative shear wave elastography parameters (mean elasticity, maximum elasticity, and elasticity ratio) were compared. The added effect of shear wave elastography on the performance of ultrasound was determined. The mean elasticity, maximum elasticity, and elasticity ratio were 24.8 kPa, 30.3 kPa, and 1.90, respectively, for 79 benign masses and 130.7 kPa, 154.9 kPa, and 11.52, respectively, for 44 malignant masses (p shear wave elastography parameter was higher than that of ultrasound (p shear wave elastography parameters to the evaluation of BI-RADS category 4a masses, about 90% of masses could be downgraded to BI-RADS category 3. The numbers of downgraded masses were 40 of 44 (91%) for mean elasticity, 39 of 44 (89%) for maximum elasticity, and 42 of 44 (95%) for elasticity ratio. The numbers of correctly downgraded masses were 39 of 40 (98%) for mean elasticity, 38 of 39 (97%) for maximum elasticity, and 41 of 42 (98%) for elasticity ratio. There was improvement in the diagnostic performance of ultrasound of mass assessment with shear wave elastography parameters added to BI-RADS category 4a masses compared with ultrasound alone. Combined ultrasound and elasticity ratio had the highest improvement, from 35.44% to 87.34% for specificity, from 45.74% to 80.77% for positive predictive value, and from 57.72% to 90.24% for accuracy (p shear wave elastography parameters of benign and malignant solid breast masses. By adding shear wave elastography parameters to BI-RADS category 4a masses, we found that about 90% of them could be correctly downgraded to BI-RADS category 3, thereby avoiding biopsy. Elasticity ratio

  6. NEDO project reports. High performance industrial furnace development project - High temperature air combustion

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2000-03-21

    For the purpose of reducing energy consumption, a NEDO project 'Developmental research on high efficiency industrial furnaces' was carried out from FY 1993 to FY 1999 by The Japan Industrial Furnaces Manufacturers Association, and the paper outlined the details of the project. Industrial furnaces handled in this R and D can bring 30% reduction of the energy consumption and approximately 50% NOx reduction, and were given the 9th Nikkei global environmental technology prize. In the study of combustion phenomena of high temperature air combustion, the paper arranged characteristics of flame, the base of gaseous fuel flame, the base of liquid fuel flame, the base of solid fuel flame, etc. Concerning high temperature air combustion models for simulation, fluid dynamics and heat transfer models, and reaction and NOx models, etc. As to impacts of high temperature air combustion on performance of industrial furnaces, energy conservation, lowering of pollution, etc. In relation to a guide for the design of high efficiency industrial furnaces, flow charts, conceptual design, evaluation method for heat balance and efficiency using charts, combustion control system, applicability of high efficiency industrial furnaces, etc. (NEDO)

  7. NEDO project reports. High performance industrial furnace development project - High temperature air combustion

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2000-03-21

    For the purpose of reducing energy consumption, a NEDO project 'Developmental research on high efficiency industrial furnaces' was carried out from FY 1993 to FY 1999 by The Japan Industrial Furnaces Manufacturers Association, and the paper outlined the details of the project. Industrial furnaces handled in this R and D can bring 30% reduction of the energy consumption and approximately 50% NOx reduction, and were given the 9th Nikkei global environmental technology prize. In the study of combustion phenomena of high temperature air combustion, the paper arranged characteristics of flame, the base of gaseous fuel flame, the base of liquid fuel flame, the base of solid fuel flame, etc. Concerning high temperature air combustion models for simulation, fluid dynamics and heat transfer models, and reaction and NOx models, etc. As to impacts of high temperature air combustion on performance of industrial furnaces, energy conservation, lowering of pollution, etc. In relation to a guide for the design of high efficiency industrial furnaces, flow charts, conceptual design, evaluation method for heat balance and efficiency using charts, combustion control system, applicability of high efficiency industrial furnaces, etc. (NEDO)

  8. Diffuse Infiltrative Splenic Lymphoma: Diagnostic Efficacy of Arterial-Phase CT

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Jeong Eun; Cho, June-Sik; Shin, Kyung Sook; Kim, Song Soo; You, Sun Kyoung; Park, Jae Woo; Shin, Hye Soo; Yoon, Yeo Chang [Department of Radiology, Chungnam National University Hospital, Chungnam National University College of Medicine, Daejeon 35015 (Korea, Republic of)

    2016-11-01

    To evaluate the diagnostic performance of obliteration of normal heterogeneous enhancement of the spleen (ONHES) on arterial phase (AP) computed tomography (CT) images in diffuse infiltrative splenic lymphoma (DISL). One hundred and thirty-six patients with lymphoma who had undergone two-phase (arterial and portal venous) abdominal CT were included in this study. We retrospectively evaluated the diagnostic performance of ONHES on AP CT in diagnosing DISL. Two observers evaluated ONHES on AP CT using the 5-point confidence level and assessed the presence or absence of subjective splenomegaly on axial CT images. Another two observers measured the splenic index as proposed by objective CT criteria. Statistical analysis included interobserver agreement and diagnostic performance of CT findings. Eleven of the 136 patients with lymphoma had DISL. The area under the receiver operating characteristic curve of ONHES (0.948 for observer 1 and 0.922 for observer 2) was superior to that of the splenic index (0.872 for observer 3 and 0.877 for observer 4), but the difference was not statistically significant (p > 0.05). The diagnostic performance of ONHES in conjunction with subjective splenomegaly showed higher diagnostic performance, as compared with subjective splenomegaly alone (accuracy: 100% and 85.3% for observer 1, 98.5% and 87.5% for observer 2; positive predictive value: 100% and 35.5% for observer 1, 90.9% and 39.3% for observer 2, respectively). Obliteration of normal heterogeneous enhancement of the spleen in conjunction with subjective splenomegaly can improve the diagnostic performance for DISL. Our results suggest that ONHES on AP CT images could be useful as an adjunctive diagnostic indicator of DISL in patients with lymphoma.

  9. Diffuse infiltrative splenic lymphoma; Diagnostic efficacy of arterial-phase CT

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Jeong Eun; Cho, June Sik; Shin, Kyung Sook; Kim, Song Soo; You, Sun Kyoung; Park, Jae Woo; Shin, Hye Soo; Yoon, Yeo Chang [Dept. of Radiology, Chungnam National University Hospital, Chungnam National University College of Medicine, Daejeon (Korea, Republic of)

    2016-09-15

    To evaluate the diagnostic performance of obliteration of normal heterogeneous enhancement of the spleen (ONHES) on arterial phase (AP) computed tomography (CT) images in diffuse infiltrative splenic lymphoma (DISL). One hundred and thirty-six patients with lymphoma who had undergone two-phase (arterial and portal venous) abdominal CT were included in this study. We retrospectively evaluated the diagnostic performance of ONHES on AP CT in diagnosing DISL. Two observers evaluated ONHES on AP CT using the 5-point confidence level and assessed the presence or absence of subjective splenomegaly on axial CT images. Another two observers measured the splenic index as proposed by objective CT criteria. Statistical analysis included interobserver agreement and diagnostic performance of CT findings. Eleven of the 136 patients with lymphoma had DISL. The area under the receiver operating characteristic curve of ONHES (0.948 for observer 1 and 0.922 for observer 2) was superior to that of the splenic index (0.872 for observer 3 and 0.877 for observer 4), but the difference was not statistically significant (p > 0.05). The diagnostic performance of ONHES in conjunction with subjective splenomegaly showed higher diagnostic performance, as compared with subjective splenomegaly alone (accuracy: 100% and 85.3% for observer 1, 98.5% and 87.5% for observer 2; positive predictive value: 100% and 35.5% for observer 1, 90.9% and 39.3% for observer 2, respectively). Obliteration of normal heterogeneous enhancement of the spleen in conjunction with subjective splenomegaly can improve the diagnostic performance for DISL. Our results suggest that ONHES on AP CT images could be useful as an adjunctive diagnostic indicator of DISL in patients with lymphoma.

  10. Diffuse Infiltrative Splenic Lymphoma: Diagnostic Efficacy of Arterial-Phase CT

    International Nuclear Information System (INIS)

    Lee, Jeong Eun; Cho, June-Sik; Shin, Kyung Sook; Kim, Song Soo; You, Sun Kyoung; Park, Jae Woo; Shin, Hye Soo; Yoon, Yeo Chang

    2016-01-01

    To evaluate the diagnostic performance of obliteration of normal heterogeneous enhancement of the spleen (ONHES) on arterial phase (AP) computed tomography (CT) images in diffuse infiltrative splenic lymphoma (DISL). One hundred and thirty-six patients with lymphoma who had undergone two-phase (arterial and portal venous) abdominal CT were included in this study. We retrospectively evaluated the diagnostic performance of ONHES on AP CT in diagnosing DISL. Two observers evaluated ONHES on AP CT using the 5-point confidence level and assessed the presence or absence of subjective splenomegaly on axial CT images. Another two observers measured the splenic index as proposed by objective CT criteria. Statistical analysis included interobserver agreement and diagnostic performance of CT findings. Eleven of the 136 patients with lymphoma had DISL. The area under the receiver operating characteristic curve of ONHES (0.948 for observer 1 and 0.922 for observer 2) was superior to that of the splenic index (0.872 for observer 3 and 0.877 for observer 4), but the difference was not statistically significant (p > 0.05). The diagnostic performance of ONHES in conjunction with subjective splenomegaly showed higher diagnostic performance, as compared with subjective splenomegaly alone (accuracy: 100% and 85.3% for observer 1, 98.5% and 87.5% for observer 2; positive predictive value: 100% and 35.5% for observer 1, 90.9% and 39.3% for observer 2, respectively). Obliteration of normal heterogeneous enhancement of the spleen in conjunction with subjective splenomegaly can improve the diagnostic performance for DISL. Our results suggest that ONHES on AP CT images could be useful as an adjunctive diagnostic indicator of DISL in patients with lymphoma

  11. Early evaluation of a second generation information monitoring and diagnostic system

    Energy Technology Data Exchange (ETDEWEB)

    Piette, Mary Ann; Kinney, Satkartar; Bourassa, Norman; Xu, Peng; Haves, Philip; Kinney, Kristopher; Shockman, Christine

    2002-03-25

    Private sector commercial office buildings are challenging environments for energy efficiency projects. This challenge is related to the complexity of business environments that involve ownership, operation, and tenant relationships. Whether it is poor quality design, inefficient operations, degradation of equipment over time, or merely the increasing use of energy by tenants and inattention from landlords, commercial office building energy use continues to increase. This research project was developed to examine the environment for building operations and identify causes of inefficient use of energy related to technical and organizational issues. This report discusses a second-generation Information Monitoring and Diagnostic System (IMDS) installed at a leased office building in Sacramento, California. The report begins with a brief summary of the IMDS research at the previous building, followed by a discussion of the building selection process, the IMDS design and installation, recent use of the IMDS, costs and benefits, and fault detection and diagnostic research using the IMDS. A web site describes the IMDS in detail (see imds.lbl.gov). The underlying principle of this research project is that high quality building performance data can help show where energy is being used and how buildings systems actually perform is an important first step toward improving building energy efficiency. The project utilizes a high-quality monitoring system that has been developed during the past decade by a partnership between LBNL and private industry. This research project has been successful in demonstrating that the IMDS is tremendously valuable to the building operators at the Sacramento site. The building operators not only accept the technology, but it has become the core of their day-to-day building control concepts. The innovative property management company, Jones Lang LaSalle, is interested in installing more sites to determine if the system could provide an economic

  12. Technology Issues of Burning Plasma Diagnostics

    International Nuclear Information System (INIS)

    Kaye, A. S.

    2008-01-01

    The ITER Tokamak will require many diagnostics both for safe and reliable operation of the machine and for understanding of the physics underlying the performance. The design of these diagnostics raises many challenging technical issues not faced on smaller machines. These arise partly from the increase demands on established diagnostics arising from the increased size, higher magnetic field, large heating power, and in particular the dramatically longer pulse duration of ITER, which make issue such as power loading on first wall components more challenging. The demands on reliability and availability of the machine in order to achieve the objectives within the agreed time schedule also place severe additional demands on the design, quality assurance and maintainability of diagnostics. ITER will produce many orders of magnitude more neutrons than previous Tokamaks and will be a licensed nuclear facility. This has important implications for the traceability, quality assurance and availability of safety critical diagnostics, and for the control of the design and procurement of all diagnostics. The high neutron flux/fluence also constrains the design of diagnostics, which must offer shielding consistent with the allowable dose rates on critical components of the Tokamak, and themselves be tolerant of the radiation level at the diagnostic. This paper presents an overview of the more critical issues for ITER diagnostics

  13. Integrated control and diagnostic system architectures for future installations

    International Nuclear Information System (INIS)

    Wood, R.; March-Leuba, J.

    2000-01-01

    Nuclear reactors of the 21st century will employ increasing levels of automation and fault tolerance to increase availability, reduce accident risk, and lower operating costs. Key developments in control algorithms, fault diagnostics, fault tolerance, and distributed communications are needed to implement the fully automated plant. It will be equally challenging to integrate developments in separate information and control fields into a cohesive system, which collectively achieves the overall goals of improved safety, reliability, maintainability, and cost-effectiveness. Under the Nuclear Energy Research Initiative (NERI), the US Department of Energy is sponsoring a project to address some of the technical issues involved in meeting the long-range goal of 21st century reactor control systems. This project involves researchers from Oak Ridge National Laboratory, the University of Tennessee, and North Carolina State University. The research tasks under this project focus on some of the first-level breakthroughs in control design, diagnostic techniques, and information system design that will provide a path to enable the design process to be automated in the future. This paper describes the conceptual development of an integrated nuclear plant control and information system architecture, which incorporates automated control system development that can be traced to a set of technical requirements. The expectation is that an integrated plant architecture with optimal control and efficient use of diagnostic information can reduce the potential for operational errors and minimize challenges to the plant safety systems

  14. Expert Systems Based Clinical Assessment and Tutorial Project.

    Science.gov (United States)

    Papa, Frank; Shores, Jay

    This project at the Texas College of Osteopathic Medicine (Fort Worth) evaluated the use of an artificial-intelligence-derived measure, "Knowledge-Based Inference Tool" (KBIT), as the basis for assessing medical students' diagnostic capabilities and designing instruction to improve diagnostic skills. The instrument was designed to…

  15. Diagnostic colonoscopy: performance measurement study.

    Science.gov (United States)

    Kuznets, Naomi

    2002-07-01

    This is the fifth of a series of best practices studies undertaken by the Performance Measurement Initiative (PMI), the centerpiece of the Institute for Quality Improvement (IQI), a not-for-profit quality improvement subsidiary of the Accreditation Association for Ambulatory Health Care (AAAHC) (Performance Measurement Initiative, 1999a, 1999b, 2000a, 2000b). The IQI was created to offer clinical performance measurement and improvement opportunities to ambulatory health care organizations and others interested in quality patient care. The purpose of the study was to provide opportunities to initiate clinical performance measurement on key processes and outcomes for this procedure and use this information for clinical quality improvement. This article provides performance measurement information on how organizations that have demonstrated and validated differences in clinical practice can have similar outcomes, but at a dramatically lower cost. The intent of the article is to provide organizations with alternatives in practice to provide a better value to their patients.

  16. Progress in diagnostic techniques for sc cavities

    International Nuclear Information System (INIS)

    Reece, C.E.

    1988-01-01

    While routinely achieved performance characteristics of superconducting cavities have now reached a level which makes them useful in large scale applications, achieving this level has come only through the knowledge gained by systematic studies of performance limiting phenomena. Despite the very real progress that has been made, the routine performance of superconducting cavities still falls far short of both the theoretical expectations and the performance of a few exception examples. It is the task of systematically applied diagnostic techniques to reveal additional information concerning the response of superconducting surfaces to applied RF fields. Here recent developments in diagnostic techniques are discussed. 18 references, 12 figures

  17. Using Technology-Enhanced, Cooperative, Group-Project Learning for Student Comprehension and Academic Performance

    Science.gov (United States)

    Tlhoaele, Malefyane; Suhre, Cor; Hofman, Adriaan

    2016-01-01

    Cooperative learning may improve students' motivation, understanding of course concepts, and academic performance. This study therefore enhanced a cooperative, group-project learning technique with technology resources to determine whether doing so improved students' deep learning and performance. A sample of 118 engineering students, randomly…

  18. Combined diagnostic performance of coronary computed tomography angiography and computed tomography derived fractional flow reserve for the evaluation of myocardial ischemia: A meta-analysis.

    Science.gov (United States)

    Tan, Xiao Wei; Zheng, Qishi; Shi, Luming; Gao, Fei; Allen, John Carson; Coenen, Adriaan; Baumann, Stefan; Schoepf, U Joseph; Kassab, Ghassan S; Lim, Soo Teik; Wong, Aaron Sung Lung; Tan, Jack Wei Chieh; Yeo, Khung Keong; Chin, Chee Tang; Ho, Kay Woon; Tan, Swee Yaw; Chua, Terrance Siang Jin; Chan, Edwin Shih Yen; Tan, Ru San; Zhong, Liang

    2017-06-01

    To evaluate the combined diagnostic accuracy of coronary computed tomography angiography (CCTA) and computed tomography derived fractional flow reserve (FFRct) in patients with suspected or known coronary artery disease (CAD). PubMed, The Cochrane library, Embase and OpenGray were searched to identify studies comparing diagnostic accuracy of CCTA and FFRct. Diagnostic test measurements of FFRct were either extracted directly from the published papers or calculated from provided information. Bivariate models were conducted to synthesize the diagnostic performance of combined CCTA and FFRct at both "per-vessel" and "per-patient" levels. 7 articles were included for analysis. The combined diagnostic outcomes from "both positive" strategy, i.e. a subject was considered as "positive" only when both CCTA and FFRct were "positive", demonstrated relative high specificity (per-vessel: 0.91; per-patient: 0.81), high positive likelihood ratio (LR+, per-vessel: 7.93; per-patient: 4.26), high negative likelihood ratio (LR-, per-vessel: 0.30; per patient: 0.24) and high accuracy (per-vessel: 0.91; per-patient: 0.81) while "either positive" strategy, i.e. a subject was considered as "positive" when either CCTA or FFRct was "positive", demonstrated relative high sensitivity (per-vessel: 0.97; per-patient: 0.98), low LR+ (per-vessel: 1.50; per-patient: 1.17), low LR- (per-vessel: 0.07; per-patient: 0.09) and low accuracy (per-vessel: 0.57; per-patient: 0.54). "Both positive" strategy showed better diagnostic performance to rule in patients with non-significant stenosis compared to "either positive" strategy, as it efficiently reduces the proportion of testing false positive subjects. Copyright © 2017 Elsevier B.V. All rights reserved.

  19. Hybrid case-neural network (CNN) diagnostic system

    International Nuclear Information System (INIS)

    Mohamed, A.H.

    2010-01-01

    recently, the mobile health care has a great attention for the researcher and people all over the world. Case based reasoning (CBR) systems have proved their performance as world wide web (WWW) medical diagnostic systems. They were preferred rather than different reasoning approaches due to their high performance and results' explanation. But, their operations require a complex knowledge acquisition and management processes. On the other hand, it is found that, artificial neural network (ANN) has a great acceptance as a classifier methodology using a little amount of knowledge. But, ANN lacks of an explanation capability .The present research introduces a new web-based hybrid diagnostic system that can use the ANN inside the CBR , cycle.It can provide higher performance for the web diagnostic systems. Besides, the proposed system can be used as a web diagnostic system. It can be applied for diagnosis different types of systems in several domains. It has been applied in diagnosis of the cancer diseases that has a great spreading in recent years as a case of study . However, the suggested system has proved its acceptance in the manner.

  20. [Diagnostic process and management of schizophrenia in Spain: the ACEE project].

    Science.gov (United States)

    Baca Baldomero, E; Leal Cercós, C; Varela, C; Riesgo, Y; Roca, M

    2006-01-01

    Although schizophrenia has a great impact on the health care, social and family levels, there is little epidemiological information on patients with schizophrenia, its diagnosis and treatment in Spain. The ACEE (Abordaje Clínico de la Esquizofrenia en España; Clinical Approach to Schizophrenia in Spain) study was designed with the primary objective of defining the management of schizophrenia in Spain from the perspective of current clinical practice. ACEE is a descriptive cross-sectional multicenter observational study with data collected in the setting of current clinical practice by means of a specifically designed questionnaire. A total of 1,937 patients have been studied (83% pertaining to the public sector and 17% to private one). Most subjects had paranoid schizophrenia in the stabilization phase, and did not work because of their illness. Most (96%) were receiving antipsychotic treatment and 55% also received some non-drug treatment. Negative symptoms were more frequent than positive symptoms (88% versus 63%). Significant differences were observed for type of patients and diagnostic procedures involved between the public and private health care sectors. The ACEE study shows that schizophrenic patients attending Spanish psychiatric centers are mainly single, non-working males who are living in their family setting. Treatment basically consists of antipsychotics combined with other drugs, and few complementary examinations are performed.