WorldWideScience

Sample records for programmed ultrasound examination

  1. Nursing ultrasound examination in catheterization

    Directory of Open Access Journals (Sweden)

    Luca Romei

    2007-12-01

    Full Text Available Ultrasound (US examination of the bladder can precisely determine the bladder volume and is a useful tool in estimating the residual urine volume. Its application is consequently recommended as an alternative to catheterization for the determination of residual urine. Moreover it represents a simple, noninvasive method to predict the outcome of a voiding trial following acute urine retention based on intravesical prostatic protrusion and on the US pattern of the bladder content. In this article, the Authors review the implementation and results of a bladder US program developed for non-medical caregivers at one Emergency Department.

  2. Training Program for Cardiology Residents to Perform Focused Cardiac Ultrasound Examination with Portable Device.

    Science.gov (United States)

    Siqueira, Vicente N; Mancuso, Frederico J N; Campos, Orlando; De Paola, Angelo A; Carvalho, Antonio C; Moises, Valdir A

    2015-10-01

    Training requirements for general cardiologists without echocardiographic expertise to perform focused cardiac ultrasound (FCU) with portable devices have not yet been defined. The objective of this study was to evaluate a training program to instruct cardiology residents to perform FCU with a hand-carried device (HCD) in different clinical settings. Twelve cardiology residents were subjected to a 50-question test, 4 lectures on basic echocardiography and imaging interpretation, the supervised interpretation of 50 echocardiograms and performance of 30 exams using HCD. After this period, they repeated the written test and were administered a practical test comprising 30 exams each (360 patients) in different clinical settings. They reported on 15 parameters and a final diagnosis; their findings were compared to the HCD exam of a specialist in echocardiography. The proportion of correct answers on the theoretical test was higher after training (86%) than before (51%; P = 0.001). The agreement was substantial among the 15 parameters analyzed (kappa ranging from 0.615 to 0.891; P < 0.001). The percentage of correct interpretation was lower for abnormal (75%) than normal (95%) items, for valve abnormalities (85%) compared to other items (92%) and for graded scale (87%) than for dichotomous (95%) items (P < 0.0001, for all). For the final diagnoses, the kappa value was higher than 0.941 (P < 0.001; 95% CI [0.914, 0.955]). The training proposed enabled residents to perform FCU with HCD, and their findings were in good agreement with those of a cardiologist specialized in echocardiography. © 2015, Wiley Periodicals, Inc.

  3. Ultrasound examination of the thyroid

    Energy Technology Data Exchange (ETDEWEB)

    Swaenepoel, L.; Demeester-Mirkine, N.; Sacre, R.; Jockheer, M.H.; van Geertruyden, J.

    1982-07-01

    Ultrasound examination of the thyroid offers an accurate morphological picture and the possibility of comparing objectively the size of lobes and lesions over long periods. Cysts and calcifications, mostly benign, are readily recognized. Neoplastic lesions in our series were all less reflective than normal thyroid tissue. But so were the majority of benign nodules. In hyperthyroidism, subacute thyroiditis and Hashimoto's thyroiditis, the thyroid tissue is much less echogenic than in the normal gland.

  4. Factors influencing the examinations by means of ultrasounds

    International Nuclear Information System (INIS)

    Brocco, M.

    1988-01-01

    The reliability of ultrasound examination can be influenced by many variables: the pulse generator and receiver, the material under examination, size, type, position and orientation of a defect inside the material. The results of a study aiming at evaluating the amplitude of the response signals as a means to size defects are exposed. The conclusions have been drawn considering the influence that a defect and an ultrasound system have on the power absorbed. The results show that the orientation, the geometry and the band width of the ultrasound system

  5. Standards of the Polish Ultrasound Society – update. Ultrasound examination of thyroid gland and ultrasound-guided thyroid biopsy

    Directory of Open Access Journals (Sweden)

    Anna Trzebińska

    2014-03-01

    Full Text Available Ultrasonography is a primary imaging technique in patients with suspected thyroid disease. It allows to assess the location, size and echostructures of the thyroid gland as well as detect focal lesions, along with indication of their size, echogenicity, echostructure and vascularity. Based on these features, ultrasound examination allows to predict abnormal focal lesions for biopsy and monitor the biopsy needle track. This paper presents the standards of thyroid ultrasound examination regarding ultrasound apparatus technical requirements, scanning techniques, readings, measurements, and the description of the examination. It discusses the ultrasound features of increased malignancy risk in focal lesions (nodules found in the thyroid gland. It presents indications for fine needle aspiration biopsy of the thyroid gland for the visibility of single nodules (focal lesions and numerous lesions as well as discusses contraindications for thyroid biopsy. It describes the biopsy technique, possible complications and rules for post-biopsy monitoring of benign lesions. The paper is an update of the Standards of the Polish Ultrasound Society issued in 2011. It has been prepared on the basis of current literature, taking into account the information contained in the following publications: Thyroid ultrasound examination and Recommendations of the Polish Ultrasound Society for the performance of the FNAB of the thyroid.

  6. Usefulness of Ultrasound Examinations in the Diagnostics of Necrotizing Enterocolitis

    International Nuclear Information System (INIS)

    Staryszak, Joanna; Stopa, Joanna; Kucharska-Miąsik, Iwona; Osuchowska, Magdalena; Guz, Wiesław; Błaż, Witold

    2015-01-01

    Necrotizing enterocolitis (NEC) is one of the most serious disorders of gastrointestinal tract during neonatal period. Early diagnosis and adequate treatment are essential in the presence of clinical suspicion of NEC. Plain abdominal radiography is currently the modality of choice for initial evaluation of gastrointestinal tract in neonates. However, when the diagnosis is uncertain, abdominal ultrasound with bowel assessment might be an important complementary examination. The aim of the study was to evaluate usefulness of ultrasound in the diagnosis of NEC and its value for implementation of proper treatment. The data of nine neonates diagnosed with NEC, hospitalized at the Provincial Hospital No. 2 in Rzeszow in the period from September 2009 to April 2013 was retrospectively analyzed. Apart from abdominal radiography, abdominal ultrasound with bowel assessment was performed in all nine cases. Imaging findings, epidemiological data, coexisting risk factors and disease course were assessed. Most children in the group were preterm neonates. Findings in plain abdominal radiography were normal or nonspecific. A wider spectrum of findings was demonstrated in all ultrasound examinations and intestinal pneumatosis, a pathognomonic sign for NEC, was more frequently noted than in plain abdominal x-ray. Most children were treated by surgical intervention with resection of necrotic bowel loops and in more than half of the cases location of changes identified during surgery was concordant with ultrasonographic findings. Abdominal ultrasound examination might be helpful in the diagnosis of NEC, especially when plain abdominal radiography findings do not correlate with clinical symptoms. However, abdominal radiography is still considered the modality of choice. The range of morphological changes detectable on ultrasound examination is much wider than in plain abdominal radiography. Ultrasound examination allows for more accurate assessment of changes within intestines and

  7. Cardiac Limited Ultrasound Examination Techniques to Augment the Bedside Cardiac Physical Examination.

    Science.gov (United States)

    Kimura, Bruce J; Shaw, David J; Amundson, Stan A; Phan, James N; Blanchard, Daniel G; DeMaria, Anthony N

    2015-09-01

    The current practice of physical diagnosis is dependent on physician skills and biases, inductive reasoning, and time efficiency. Although the clinical utility of echocardiography is well known, few data exist on how to integrate 2-dimensional screening "quick-look" ultrasound applications into a novel, modernized cardiac physical examination. We discuss the evidence basis behind ultrasound "signs" pertinent to the cardiovascular system and elemental in synthesis of bedside diagnoses and propose the application of a brief cardiac limited ultrasound examination based on these signs. An ultrasound-augmented cardiac physical examination can be taught in traditional medical education and has the potential to improve bedside diagnosis and patient care. © 2015 by the American Institute of Ultrasound in Medicine.

  8. Field: A Program for Simulating Ultrasound Systems

    DEFF Research Database (Denmark)

    Jensen, Jørgen Arendt

    1997-01-01

    A program for the simulation of ultrasound systems is presented.It is based on the Tupholme-Stepanishen method, and is fastbecause of the use of a far-field approximation. Any kind oftransducer geometry and excitation can be simulated, and bothpulse-echo and continuous wave fields can be calculated...... for bothtransmit and pulse-echo. Dynamic apodization and focusing arehandled through time lines, and different focusingschemes can be simulated. The versatility of the program isensured by interfacing it to Matlab. All routines are calleddirectly from Matlab, and all Matlab features can be used. Thismakes...

  9. [Ultrasound examination for lower extremity deep vein thrombosis].

    Science.gov (United States)

    Toyota, Kosaku

    2014-09-01

    Surgery is known to be a major risk factor of vein thrombosis. Progression from lower extremity deep vein thrombosis (DVT) to pulmonary embolism can lead to catastrophic outcome, although the incidence ratio is low. The ability to rule in or rule out DVT is becoming essential for anesthesiologists. Non-invasive technique of ultrasonography is a sensitive and specific tool for the assessment of lower extremity DVT. This article introduces the basics and practical methods of ultrasound examination for lower extremity DVT.

  10. Ultrasound findings and histological features of ductal carcinoma in situ detected by ultrasound examination alone

    OpenAIRE

    Izumori, Ayumi; Takebe, Koji; Sato, Akira

    2009-01-01

    Background With the increasing use of high-resolution ultrasound (US) examination, many breast carcinomas that cannot be identified by mammography (MMG) alone have been detected. Many of these carcinomas are ductal carcinoma in situ (DCIS) and small-sized invasive carcinomas. Until date, DCISs have often been described as palpable masses with calcifications on MMG, but what are the characteristics of DCISs that are detectable by US alone? Methods One hundred fifty cases with DCIS that we expe...

  11. Functional anatomy and ultrasound examination of the canine penis.

    Science.gov (United States)

    Goericke-Pesch, Sandra; Hölscher, Catharina; Failing, Klaus; Wehrend, Axel

    2013-07-01

    The aim of this study was to identify the functional-anatomical structures of the canine penis during and after erection to demonstrate the respective changes to provide a basis for further examinations of pathological conditions like priapism. Additionally, a gray-scale analysis was performed to quantify results from the ultrasound examination. In total, 80 dogs were examined. In group (Gr.) A, 44 intact or castrated dogs were examined, and in Gr. B, 36 dogs were examined during erection and after complete detumescence of the penis. The following parameters were assessed: (1) using physical measurements: length of the Pars longa glandis [Plg] and length of the Bulbus glandis [Bg]; and (2) using ultrasound: total penile diameter, width of the erectile tissue of the Plg, diameter of the Corpus spongiosum [Cs] including the penile bone and urethra, vertical diameter, circumference of the penis, cross-sectional area, and area of the Cs including the urethra. The mentioned parameters could be assessed in all dogs of Gr. A and Gr. B with the only exception being the urethra that could be visualized using ultrasound in some dogs only and predominantly in the erected penis (Gr. B). Concomitantly, the erectile tissue of the Plg and the Cs was more heterogenous and hypo- to anechoic during erection compared with dogs in Gr. A and Gr. B after detumescence. Comparing the results in Gr. B, the length of the Plg and the Bg were decreased approximately 40.6% and 38.0%, the total width of the penis 40.5%, the total width of the erectile tissue of the Plg 48.0%, and the width of the Cs 15.6% during detumescence compared with erection. Comparing the decrease in size at the different locations (apex penis, middle of Plg, middle of Bg) for vertical diameter, total circumference, and cross-section area, it was largest at the Bg. B-mode ultrasound is a suitable tool to investigate not only the morpho-functional structures of the resting canine penis, but also of the erected and

  12. Hyperthyroidism and Graves' disease: Is an ultrasound examination needed?

    Directory of Open Access Journals (Sweden)

    Lakshminarayanan Varadhan

    2016-01-01

    Full Text Available Aim: The aim of our study was to assess the limitation of clinical examination in determining the morphology of thyroid gland in patients with hyperthyroidism and its implications. Methods: A retrospective analysis of consecutive patients with hyperthyroidism seen in a tertiary endocrine clinic were analyzed. Sub-analysis was performed on patients with proven Graves' disease. Results: Of the 133 patients included in this study with hyperthyroidism, 60 (45% patients had significant nodularity on ultrasound (US. However, only 67% of these were identified on clinical examination. In patients with confirmed Graves' disease (n = 73, the discordance between US and clinical examination was very similar (18 of 30 patients, 60%. Conclusion: US should form an essential part of the evaluation of hyperthyroidism as the morphology of thyroid gland could be variable and nodules in these glands would also need to be appropriately investigated. This would also significantly influence decision-making and appropriate immediate and follow-up management plan.

  13. Nerve ultrasound reliability of upper limbs: Effects of examiner training.

    Science.gov (United States)

    Garcia-Santibanez, Rocio; Dietz, Alexander R; Bucelli, Robert C; Zaidman, Craig M

    2018-02-01

    Duration of training to reliably measure nerve cross-sectional area with ultrasound is unknown. A retrospective review was performed of ultrasound data, acquired and recorded by 2 examiners-an expert and either a trainee with 2 months (novice) or a trainee with 12 months (experienced) of experience. Data on median, ulnar, and radial nerves were reviewed for 42 patients. Interrater reliability was good and varied most with nerve site but little with experience. Coefficient of variation (CoV) range was 9.33%-22.5%. Intraclass correlation coefficient (ICC) was good to excellent (0.65-95) except ulnar nerve-wrist/forearm and radial nerve-humerus (ICC = 0.39-0.59). Interrater differences did not vary with nerve size or body mass index. Expert-novice and expert-experienced interrater differences and CoV were similar. The ulnar nerve-wrist expert-novice interrater difference decreased with time (r s  = -0.68, P = 0.001). A trainee with at least 2 months of experience can reliably measure upper limb nerves. Reliability varies by nerve and location and slightly improves with time. Muscle Nerve 57: 189-192, 2018. © 2017 Wiley Periodicals, Inc.

  14. Assessment of performance measures and learning curves for use of a virtual-reality ultrasound simulator in transvaginal ultrasound examination

    DEFF Research Database (Denmark)

    Madsen, M E; Konge, L; Nørgaard, L N

    2014-01-01

    OBJECTIVE: To assess the validity and reliability of performance measures, develop credible performance standards and explore learning curves for a virtual-reality simulator designed for transvaginal gynecological ultrasound examination. METHODS: A group of 16 ultrasound novices, along with a group......-6), corresponding to an average of 219 min (range, 150-251 min) of training. The test/retest reliability was high, with an intraclass correlation coefficient of 0.93. CONCLUSIONS: Competence in the performance of gynecological ultrasound examination can be assessed in a valid and reliable way using virtual-reality...

  15. [Prognostic Doppler ultrasound examination of fetal arteries blood flow].

    Science.gov (United States)

    Sieroszewski, Piotr; Sabatowska, Małgorzata; Karowicz-Bilińska, Agata; Suzin, Jacek

    2002-08-01

    Early detection of fetal risk is one of the main issues in today obstetrics. Ultrasound diagnostics plays a significant role, as the introduction of Doppler imaging method in the evaluation of blood flow has enabled non-invasive assessment of uteroplacental circulation. Therefore, we have analysed foetal three arteries: umbilical artery, middle cerebral artery and renal artery after determining the normal range for the analysed parameters. 1. Comparison of the obtained blood flow indices (S/D, RI, PI) in the umbilical artery, middle cerebral artery and renal artery of foetuses from normal and complicated full-term pregnancies. 2. Determination of indices: umbilical-cerebral and renal-cerebral in normal and pathological pregnancy. 3. Evaluation of feasibility of the analysed flow parameters for the detection of intrauterine foetal hypoxia. We have examined 151 women, who were divided into control group--101 pregnant women with normal pregnancy and study group--50 pregnant women with complicated pregnancy. All pregnant women underwent ultrasound examination using the Hitachi EUB 515 C (Japan) scanner with 3.5 MHz convex probe, connected to the colour pulsed Doppler. The study consisted of the biometric measurements and evaluation of the spectrum of blood flow in the umbilical artery, middle cerebral artery and renal artery. We have determined following indices: a) systolic-diastolic ratio S/D, resistance index RI, pulsatility index PI, b) umbilical-cerebral ratio P/M. (PI ua/PI mca), renal--cerebral ratio N/M (PI ra/PI mca). Statistically significant difference was found between the study and control groups for all the flow indices assessed (S/D, RI, PI) for the middle cerebral artery, for the indices P/M and N/M. (p < 0.001) and pulsatility index in the renal artery (p < 0.01). Similar, although slightly smaller difference (p < 0.05) was seen for the values of flow parameters in the umbilical artery. 1) Evaluation of blood flow in the middle cerebral artery, and in

  16. Transvaginal ultrasound examination of women with and without pelvic venous congestion

    International Nuclear Information System (INIS)

    Halligan, Steve; Campbell, Deidre; Bartram, Clive I.; Rogers, Vera; El-Haddad, Cadria; Patel, Sujata; Beard, Richard W.

    2000-01-01

    AIM: To determine if transvaginal ultrasound, including power Doppler examination, can distinguish between women with and without pelvic congestion. MATERIALS AND METHODS: Thirty-six women with pelvic congestion were prospectively examined using transvaginal ultrasonography and standard uterine and ovarian measurements made. Additionally, planimetric measurements of each ovary were taken using an image analysis program to determine the cross-sectional area of ovarian stroma and follicles, if any. Power Doppler images of adnexal vessels were obtained and planimetric estimates of surface area calculated. A congestion score was assigned to each patient, based on vein number, diameter and morphology on grey-scale scanning. Identical measurements were obtained from 19 asymptomatic women and results compared. RESULTS: There was no significant difference between women with pelvic congestion and controls with respect to power Doppler or grey-scale images of adnexal vessels, or congestion score. However, women with pelvic congestion had significantly larger and multicystic ovaries when compared to controls. CONCLUSIONS: Transvaginal ultrasound measurements of adnexal vasculature, including power Doppler measurements, cannot reliably distinguish women with pelvic congestion from controls. However, ultrasound may remain useful for diagnosis of pelvic congestion, predominantly because it is able to visualize multi-cystic ovaries in these patients. Halligan, S. (2000).Clinical Radiology 55 , 954-958

  17. Study on text mining algorithm for ultrasound examination of chronic liver diseases based on spectral clustering

    Science.gov (United States)

    Chang, Bingguo; Chen, Xiaofei

    2018-05-01

    Ultrasonography is an important examination for the diagnosis of chronic liver disease. The doctor gives the liver indicators and suggests the patient's condition according to the description of ultrasound report. With the rapid increase in the amount of data of ultrasound report, the workload of professional physician to manually distinguish ultrasound results significantly increases. In this paper, we use the spectral clustering method to cluster analysis of the description of the ultrasound report, and automatically generate the ultrasonic diagnostic diagnosis by machine learning. 110 groups ultrasound examination report of chronic liver disease were selected as test samples in this experiment, and the results were validated by spectral clustering and compared with k-means clustering algorithm. The results show that the accuracy of spectral clustering is 92.73%, which is higher than that of k-means clustering algorithm, which provides a powerful ultrasound-assisted diagnosis for patients with chronic liver disease.

  18. Point-of-care cardiac ultrasound techniques in the physical examination: better at the bedside.

    Science.gov (United States)

    Kimura, Bruce J

    2017-07-01

    The development of hand-carried, battery-powered ultrasound devices has created a new practice in ultrasound diagnostic imaging, called 'point-of-care' ultrasound (POCUS). Capitalising on device portability, POCUS is marked by brief and limited ultrasound imaging performed by the physician at the bedside to increase diagnostic accuracy and expediency. The natural evolution of POCUS techniques in general medicine, particularly with pocket-sized devices, may be in the development of a basic ultrasound examination similar to the use of the binaural stethoscope. This paper will specifically review how POCUS improves the limited sensitivity of the current practice of traditional cardiac physical examination by both cardiologists and non-cardiologists. Signs of left ventricular systolic dysfunction, left atrial enlargement, lung congestion and elevated central venous pressures are often missed by physical techniques but can be easily detected by POCUS and have prognostic and treatment implications. Creating a general set of repetitive imaging skills for these entities for application on all patients during routine examination will standardise and reduce heterogeneity in cardiac bedside ultrasound applications, simplify teaching curricula, enhance learning and recollection, and unify competency thresholds and practice. The addition of POCUS to standard physical examination techniques in cardiovascular medicine will result in an ultrasound-augmented cardiac physical examination that reaffirms the value of bedside diagnosis. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2017. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  19. Ultrasound examination and behavior scoring of captive broadnose sevengill sharks, Notorynchus cepedianus (Peron, 1807).

    Science.gov (United States)

    Daly, Jonathan; Gunn, Ian; Kirby, Nick; Jones, Robert; Galloway, David

    2007-09-01

    Serial ultrasound examination of four mature female sevengill sharks (Notorynchus cepedianus) was carried out over 18 months. Monitoring the reproductive cycle and development of follicles and fetuses in sharks in a noninvasive manner using this technique has not been reported previously. Sharks were caught out of the "Oceanarium" tank by divers using a specially made catch-out bag, and brought to a holding area for examination. A behavior scoring system was used to monitor the impact of regular handling on the well-being of the animals. Ultrasound showed the growth and regression of follicles in sevengill ovaries, and allowed an approximation of the reproductive stage of these sharks. Monitoring behavior at five time points during the procedure showed that regular handling of sharks for clinical studies could be done with minimal impact on animal welfare. The ability to follow reproductive events in elasmobranches using ultrasonography is an important step in the application of assisted reproductive technology in these species. Assisted reproductive technology, such as monitoring female reproductive cycles and artificial insemination, could potentially be used to maintain genetic diversity and compliment aquaria-based breeding programs for endangered species such as the gray nurse shark (Carcharias taurus). Zoo Biol 26:383-395, 2007. (c) 2007 Wiley-Liss, Inc.

  20. Medicine and the holistic understanding of the human being: ultrasound examination as dialog.

    Science.gov (United States)

    Maio, G

    2014-04-01

    Ultrasound can capture the living nature of a person. This capturing of life depends greatly on experience as well as sense of touch, intuition, sense of speech, and not least a sense for the distinctiveness of every person. Performing ultrasound is not simply the application of a technique but rather a merging of man and technology in the framework of an interpersonal encounter. Therefore, as much should be invested in the interpersonal nature of the encounter as in the development of the technical principles of the ultrasound probe. To effectively perform ultrasound, it is necessary to avoid viewing ultrasound from a purely technical view and to always remember the importance of the relationship to the patient, particularly during the technical examination. © Georg Thieme Verlag KG Stuttgart · New York.

  1. Sustained knowledge acquisition among Rwandan physicians participating in six-month ultrasound training program

    Directory of Open Access Journals (Sweden)

    P.C. Henwood*

    2013-12-01

    Conclusions: Trainees demonstrated significant knowledge improvement after an intensive introductory ultrasound course, which increased through the training program. Mean OSCE scores remained above 80% throughout the course. Participants in an ultrasound training program with an initial training phase and periodic skill reinforcement can acquire and retain ultrasound knowledge and scanning skills.

  2. Obstetric and Gynecologic Ultrasound Curriculum and Competency Assessment in Residency Training Programs

    DEFF Research Database (Denmark)

    Abuhamad, Alfred; Minton, Katherine K; Benson, Carol B

    2018-01-01

    in Medicine assembled a multisociety task force to develop a consensus-based, standardized curriculum and competency assessment tools for obstetric and gynecologic ultrasound training in residency programs. The curriculum and competency assessment tools were developed based on existing national...... and international guidelines for the performance of obstetric and gynecologic ultrasound examinations and thus are intended to represent the minimum requirement for such training. By expert consensus, the curriculum was developed for each year of training, criteria for each competency assessment image were...... that the criteria set forth in this document will evolve with time. The task force also encourages use of ultrasound simulation in residency training and expects that simulation will play a significant part in the curriculum and the competency assessment process. Incorporating this training curriculum...

  3. Obstetric and gynecologic ultrasound curriculum and competency assessment in residency training programs

    DEFF Research Database (Denmark)

    Abuhamad, Alfred; Minton, Katherine K; Benson, Carol B

    2018-01-01

    in Medicine assembled a multisociety task force to develop a consensus-based, standardized curriculum and competency assessment tools for obstetric and gynecologic ultrasound training in residency programs. The curriculum and competency assessment tools were developed based on existing national...... and international guidelines for the performance of obstetric and gynecologic ultrasound examinations and thus are intended to represent the minimum requirement for such training. By expert consensus, the curriculum was developed for each year of training, criteria for each competency assessment image were...... that the criteria set forth in this document will evolve with time. The task force also encourages use of ultrasound simulation in residency training and expects that simulation will play a significant part in the curriculum and the competency assessment process. Incorporating this training curriculum...

  4. [Feasibility and accuracy of ultrasound-guided methodology in the examination of lumbar spine facet joints].

    Science.gov (United States)

    Wen, Chuan-Bing; Li, Yong-Zhong; Tang, Qin-Qin; Sun, Lin; Xiao, Hong; Yang, Bang-Xiang; Song, Li; Liu, Hui

    2013-03-01

    To investigate the feasibility, accuracy of B ultrasound in the examination of joint space of lumbar spine facet joints compared with CT scan. Ten healthy adult volunteers were enrolled. The joint space of lumbar facet joints was measured by ultrasound. To identify the spinal levels, the posterior parasagittal sonograms were obtained at levels L1 to S1. The lumbar facet joints were delineated with the help of transverse sonograms at each level. Meanwhile, the lumbar facet joints were evaluated by spiral CT on the same plane, reformatted to 1-mm axial slices. A total of 88 lumbar facet joints from L1 to S1 were clearly visualized in the 10 volunteers. Both ultrasound and CT measurements showed the same average depth and lateral distance of lumbar facet joint space (P > 0.05). The lumbar facet joint space can be accurately demonstrated by ultrasound.

  5. Ultrasound

    Science.gov (United States)

    Ultrasound is a useful procedure for monitoring the baby's development in the uterus. Ultrasound uses inaudible sound waves to produce a two-dimensional image of the baby while inside the mother's ...

  6. The standards of an ultrasound examination of the prostate gland. Part 2

    Directory of Open Access Journals (Sweden)

    Janusz F. Tyloch

    2017-03-01

    Full Text Available The paper discusses the rules of the proper performing of the ultrasound examination of the prostate gland. It has been divided into two parts: the general part and the detailed part. The first part presents the necessary requirements related to the ultrasound equipment needed for performing transabdominal and transrectal examinations of the prostate gland. The second part presents the application of the ultrasound examination in benign prostatic hyperplasia, in cases of prostate inflammation and in prostate cancer. Ultrasound examinations applied in the diagnostics of benign prostatic hyperplasia accelerated the diagnosis, facilitated the qualification to surgery and the selection of the treatment method. The assessment of the size of the prostate gland performed using the endorectal ultrasound examination is helpful in making the choice between transurethral electroresection and adenomectomy. In prostate inflammation this examination should be performed with particular gentleness due to pain ailments. The indication for performing the examination in acute inflammation is the suspicion of prostate abscess. In chronic, exacerbating prostatitis it is possible to perform an intraprostatic antibiotic injection. In the recent years increased morbidity and detectability of prostate gland cancer is observed among men. In Poland it ranks second (13% among diseases occurring in men. The indication for an endorectal examination is the necessity to assess the size of the prostate gland, its configuration, the echostructure in classical ultrasonography, the vascularization in an ultrasound examination performed with power doppler and, if possible, the differences in the gland tissue firmness (consistency in elastography. The ultrasound examination is used for performing the mapping biopsy of the prostate gland – from routine, strictly defined locations, the targeted biopsy – from locations suspected of neoplastic proliferation and the staging biopsy

  7. Evaluation of a Novel Wireless Transmission System for Trauma Ultrasound Examinations From Moving Ambulances.

    Science.gov (United States)

    Morchel, Herman; Ogedegbe, Chinwe; Chaplin, William; Cheney, Brianna; Zakharchenko, Svetlana; Misch, David; Schwartz, Matthew; Feldman, Joseph; Kaul, Sanjeev

    2018-03-01

    To determine if physicians trained in ultrasound interpretation perceive a difference in image quality and usefulness between Extended Focused Assessment with Sonography ultrasound examinations performed at bedside in a hospital vs. by emergency medical technicians minimally trained in medical ultrasound on a moving ambulance and transmitted to the hospital via a novel wireless system. In particular, we sought to demonstrate that useful images could be obtained from patients in less than optimal imaging conditions; that is, while they were in transport. Emergency medical technicians performed the examinations during transport of blunt trauma patients. Upon patient arrival at the hospital, a bedside Extended Focused Assessment with Sonography examination was performed by a physician. Both examinations were recorded and later reviewed by physicians trained in ultrasound interpretation. Data were collected on 20 blunt trauma patients over a period of 13 mo. Twenty ultrasound-trained physicians blindly compared transmitted vs. bedside images using 11 Questionnaire for User Interaction Satisfaction scales. Four paired samples t-tests were conducted to assess mean differences between ratings for ambulatory and base images. Although there is a slight tendency for the average rating across all subjects and raters to be slightly higher in the base than in the ambulatory condition, none of these differences are statistically significant. These results suggest that the quality of the ambulatory images was viewed as essentially as good as the quality of the base images.

  8. Prostate Ultrasound

    Medline Plus

    Full Text Available ... ultrasound or with a rectal examination, an ultrasound-guided biopsy can be performed. This procedure involves advancing ... of the Prostate) Prostate Cancer Ultrasound- and MRI-Guided Prostate Biopsy Images related to Ultrasound - Prostate Sponsored ...

  9. Usefulness of ultrasound examination in larynx traumas in children

    International Nuclear Information System (INIS)

    Jakubowska, A.; Brzewski, M.; Zawadzka-Glos, L.

    2011-01-01

    Background: The aim of the paper was to evaluate the usefulness of ultrasonographic examination in diagnosing laryngeal traumas, and monitoring the progress or complications in its treatment. Material/Method: In the years 2004 - 2009, 12 children, including 5 girls and 7 boys with laryngeal injuries, aged 5 - 12 years, were diagnosed and treated. In all the children, US examination of the neck and larynx, using a high-frequency linear transducer, as well as laryngoscopy and radiological examination of the cervical spine and chest were performed. Results: Blunt injury of the larynx was found in 12 children; in 9 children, the injury had been caused by hitting the neck against an obtuse object, 1 child had been kicked in the neck, and in one there had been an attempt of strangling. One of the children had sustained blunt injuries of the neck and chest in a traffic accident. In US examinations, the findings included: unilateral lack of vocal cord mobility in 5 children, asymmetry in vocal cord mobility in 1 child, fractured thyroid cartilage with local hematoma in the affected area in 2 children, and thickened vocal cords in 5 children. In radiological examination, the findings included: subcutaneous emphysema in the cervical area of the chest in 4 children, and mediastinal emphysema in 2 children with traumatic rupture of the trachea shown in laryngoscopy. Conclusions: US examination is helpful in the assessment of the extensiveness of laryngeal trauma, especially in the evaluation of vocal cord mobility, cervical cartilage and the soft tissues of the neck. A high level of conformity was demonstrated between the results of cervical US and the respective laryngoscopic findings. US examination does not allow to differentiate between vocal cord paralysis and their immobilization. (authors)

  10. Hyperthyroidism and Graves? disease: Is an ultrasound examination needed?

    OpenAIRE

    Varadhan, Lakshminarayanan; Varughese, George Iype; Sankaranarayanan, Sailesh

    2016-01-01

    Aim: The aim of our study was to assess the limitation of clinical examination in determining the morphology of thyroid gland in patients with hyperthyroidism and its implications. Methods: A retrospective analysis of consecutive patients with hyperthyroidism seen in a tertiary endocrine clinic were analyzed. Sub-analysis was performed on patients with proven Graves' disease. Results: Of the 133 patients included in this study with hyperthyroidism, 60 (45%) patients had significant nodularity...

  11. Ultrasound examination in diagnostic of early congenital syphilis

    Directory of Open Access Journals (Sweden)

    V. D. Zavadovskaya

    2012-01-01

    Full Text Available A peculiarity of the congenital syphilis of recent years is an increase of the number of cases of latent forms of the disease, marked with osteopathy. With the help of an examination of 50 children with early congenital syphilis, the following ultrasonic signs of a musculoskeletal system lesion were revealed: osteochondritis 90%, osteosclerosis 80%, and periostitis 30%.The comparison of the nature of a musculoskeletal system lesion with serological data of the specific process activity showed that complex manifestations of lesions with periostitis being a component were of the greatest clinical significance.

  12. Interrater reliability of quantitative ultrasound using force feedback among examiners with varied levels of experience

    Directory of Open Access Journals (Sweden)

    Michael O. Harris-Love

    2016-06-01

    Full Text Available Background. Quantitative ultrasound measures are influenced by multiple external factors including examiner scanning force. Force feedback may foster the acquisition of reliable morphometry measures under a variety of scanning conditions. The purpose of this study was to determine the reliability of force-feedback image acquisition and morphometry over a range of examiner-generated forces using a muscle tissue-mimicking ultrasound phantom. Methods. Sixty material thickness measures were acquired from a muscle tissue mimicking phantom using B-mode ultrasound scanning by six examiners with varied experience levels (i.e., experienced, intermediate, and novice. Estimates of interrater reliability and measurement error with force feedback scanning were determined for the examiners. In addition, criterion-based reliability was determined using material deformation values across a range of examiner scanning forces (1–10 Newtons via automated and manually acquired image capture methods using force feedback. Results. All examiners demonstrated acceptable interrater reliability (intraclass correlation coefficient, ICC = .98, p .90, p < .001, independent of their level of experience. The measurement error among all examiners was 1.5%–2.9% across all applied stress conditions. Conclusion. Manual image capture with force feedback may aid the reliability of morphometry measures across a range of examiner scanning forces, and allow for consistent performance among examiners with differing levels of experience.

  13. Educational value of pocket-sized ultrasound devices to improve understanding of ultrasound examination principles and sonographic anatomy for medical student.

    Directory of Open Access Journals (Sweden)

    Eun Young Kim

    Full Text Available Medical students must understand the principles of ultrasonography (US, because US examinations are an important component of patient care in clinical practice. Pocket-sized ultrasound devices have the benefits of accessibility and ease of use. The primary objective of the present study was to evaluate the educational value of these devices in terms of improving medical student interest and understanding of US and sonographic anatomy.We added a US training program comprised of a self-study learning module and a hands-on training session to a two-week block curriculum of medical imaging for first year medical students (n = 40. Multiple pocket-sized US devices were used on a small-group basis during a single afternoon. Students were asked to complete a questionnaire before and after the US training session; these two questionnaires contained 6 and 10 questions, respectively, which were rated by students using a five-point Likert scale. In addition, understanding of sonographic anatomy was tested before and after the training program.Forty students completed the two questionnaires and the anatomy-related tests. Students found the program educationally valuable (4.37 ± 0.54 of 5 and reported that US practice was useful for improving their understanding of the principles of US examinations (4.23 ± 0.66 of 5 and sonographic anatomy (4.40 ± 0.55 of 5. Overall confidence at performing US examinations and understanding of sonographic anatomy were significantly increased after US training (increased overall confidence score, 1.87 ± 0.91 and improvement in sonographic anatomy score, 6.55 ± 1.55, p values < 0.001.US training using pocket-sized ultrasound devices was found to be educationally valuable for medical students in terms of improving understanding of US principles and familiarizing students with sonographic anatomy.

  14. The estimated volume of the fibroid uterus: a comparison of ultrasound and bimanual examination versus volume at MRI or hysterectomy

    NARCIS (Netherlands)

    Stoelinga, Barbara; Huirne, Judith; Heymans, Martijn W.; Reekers, Jim A.; Ankum, Willem M.; Hehenkamp, Wouter J. K.

    2015-01-01

    The volume of a fibroid uterus before performing hysterectomy is typically estimated through bimanual examination and confirmed by ultrasonography. This study compares estimated volumes by bimanual examination and ultrasound examination with MRI and actual volumes obtained from histopathology, as

  15. Round Robin Test for Performance Demonstration System of Ultrasound Examination Personnel in Nuclear Power Plants

    International Nuclear Information System (INIS)

    Kim, Young Ho; Yang, Seung Han; Kim, Yong Sik; Yoon, Byung Sik; Lee, Hee Jong

    2005-01-01

    Ultrasound testing performance during in-service inspection for the main components of NPPs is strongly affected by each examination person. Therefore, ASME established a more strict qualification requirement in Sec. XI Appendix VIII for the ultrasound testing personnel in nuclear power plants. The Korean Performance Demonstration (KPD) System according to the ASME code for the ultrasonic testing personnel, equipments, and procedures to apply to the Class 1 and 2 piping ultrasound examination of nuclear power plants in Korea was established. And a round robin test was conducted in order to verify the effectiveness of PD method by comparing the examination results from the method of Performance Demonstration (PD) and a traditional ASME code dB-drop method. The round robin test shows that the reliability of the PD method is better than that of the dB-drop method. As a result, application of the PD method to the in-service inspection of the nuclear power plants will improve the performance of ultrasound testing

  16. A comparison of ultrasound and clinical examination in the detection of flexor tenosynovitis in early arthritis

    Directory of Open Access Journals (Sweden)

    Abouqal Redouane

    2011-05-01

    Full Text Available Abstract Background Tenosynovitis is widely accepted to be common in rheumatoid arthritis (RA and postulated to be the first manifestation of RA, but its true prevalence in early disease and in particular the hand has not been firmly established. The aims of this study were first to investigate the frequency and distribution of finger flexor tenosynovitis using ultrasound in early arthritis, second to compare clinical examination with ultrasound (US using the latter as the gold standard. Methods 33 consecutive patients who had who were initially diagnosed with polyarthritis and suspected of polyarthritis and clinical suspicion of inflammatory arthritis of the hands and wrists were assessed during consecutive, routine presentations to the rheumatology outpatient clinic. We scanned a total of 165 finger tendons and subsequent comparisons were made using clinical examination. Results Flexor tenosynovitis was found in 17 patients (51.5% on ultrasound compared with 16 (48.4% of all patients on clinical examination. Most commonly damaged joint involved on US was the second finger followed by the third, fifth, and fourth. Both modalities demonstrated more pathology on the second and third metacarpophalangeal (MCP compared with the fourth and fifth MCP. A joint-by-joint comparison of US and clinical examination demonstrated that although the sensitivity, specificities and positive predictive values of clinical examination were relatively high, negative predictive value of clinical examination was low (0.23. Conclusions Our study suggest that clinical examination can be a valuable tool for detecting flexor disease in view of its high specificity and positive predictive values, but a negative clinical examination does not exclude inflammation and an US should be considered. Further work is recommended to standardize definitions and image acquisition for peritendinous inflammation for ultrasound.

  17. RELIABILITY AND VALIDITY OF CLINICAL AND ULTRASOUND EXAMINATIONS OF DEVELOPMENTAL HIP DYSPLASIA

    Directory of Open Access Journals (Sweden)

    Predrag Grubor

    2011-03-01

    Full Text Available Developmental dysplasia of the hip (DDH is the most common congenital deformation of the musculoskeletal system and its successful treatment is closely related to early diagnosis. The study is aimed at examining the incidence of developmental dysplasia of the hip (DDH and at analysing the validity of clinical examination, which is used for the early detection of DDH in the neonatal period, compared to ultrasound examination.The study involved 400 neonates born in the Banja Luka Region. A new questionnaire was open during the first regular ultrasound and clinical examination of the neonates’ hips and anamnestic and clinical data were recorded in it: the asymmetry of the gluteal, inguinal and femoral folds (Bade sign, the result of abduction testseparately for each hip, the Ortolani sign of luxation and the Palmen sign of reposition, then hip sonography. A Toshiba ultrasound machine with a 7.5 MHz linear probe was used. The method employed was Professor Reinhard Graf’s. Out of the total number of the children with a positive sonographic finding for DDH, 63.16% of them have one of the clinical signs of DDH. The ability of a clinical finding to identify those patients who do not have DDH and have a negative sonographic finding is 79.8%. Out of the total number of the examined children with a positive clinical finding, only 15.58% of them also have a positive sonographic finding for DDH. This research has showed that clinical examination of the hips is of low sensitivity, specificity and reliability, and that not all types of DDH can be detected. Clinical examination must remain an integral part of every infant’s examination, but it constitutes a complementary diagnostic procedure to ultrasound examination. The ultrasound examination of DDH has created new possibilities and has filled the void that existed due to the deficiency of clinical tests, and at the same time it has reduced the number of X-ray examinations of the hips. This research has

  18. Chest wall – underappreciated structure in sonography. Part I: Examination methodology and ultrasound anatomy

    Directory of Open Access Journals (Sweden)

    Andrzej Smereczyński

    2017-09-01

    Full Text Available Chest wall ultrasound has been awarded little interest in the literature, with chest wall anatomy described only in limited extent. The objective of this study has been to discuss the methodology of chest wall ultrasound and the sonographic anatomy of the region to facilitate professional evaluation of this complex structure. The primarily used transducer is a 7–12 MHz linear one. A 3–5 MHz convex (curvilinear transducer may also be helpful, especially in obese and very muscular patients. Doppler and panoramic imaging options are essential. The indications for chest wall ultrasound include localized pain or lesions found or suspected on imaging with other modalities (conventional radiography, CT, MR or scintigraphy. The investigated pathological condition should be scanned in at least two planes. Sometimes, evaluation during deep breathing permits identification of pathological mobility (e.g. in rib or sternum fractures, slipping rib syndrome. Several structures, closely associated with each other, need to be considered in the evaluation of the chest wall. The skin, which forms a hyperechoic covering, requires a high frequency transducer (20–45 MHz. The subcutaneous fat is characterized by clusters of hypoechoic lobules. Chest muscles have a very complex structure, but their appearance on ultrasound does not differ from the images of muscles located in other anatomical regions. As far as cartilaginous and bony structures of the chest are concerned, the differences in the anatomy of the ribs, sternum, scapula and sternoclavicular joints have been discussed. The rich vascular network which is only fragmentarily accessible for ultrasound assessment has been briefly discussed. A comprehensive evaluation of the chest wall should include the axillary, supraclavicular, apical and parasternal lymph nodes. Their examination requires the use of elastography and contrast-enhanced ultrasound.

  19. Ultrasound and Doppler examination capabilities in adult portal hypertension type definition

    Directory of Open Access Journals (Sweden)

    N. V. Tumanskaya

    2015-08-01

    Full Text Available Early portal hypertension type diagnostics is an ultimate factor concerning kind and tactics of treatment. Aim. To objectify ultrasound examination capabilities, portal hemodynamics were studied in 97 patients using impulse and color doppler. Methods and results. It was ascertained that impulse and color doppler examination allows to visualize portal vein and its branches’ structural abnormalities, define subhepatic and intrahepatic types of portal hypertension, find thrombosis and characterize its stages. In cirrhosis patients with portal hypertension, homogenous doppler signal was received from the portal vessels lumen, while signs of intraluminar pathology were seen in the case of thrombosis of portal vein. Conclusion. This means that ultrasound examination of portal vein and its branches with impulse and color doppler is informative, non invasive method, which helps to define stages of portal hypertension. Doppler ultrasonography doesn’t have negative effect of ionizing radiation and can be used for the repeated research in the dynamics of disease.

  20. Ultrasound

    Science.gov (United States)

    ... completed. Young children may need additional preparation. When scheduling an ultrasound for yourself or your child, ask ... of Privacy Practices Notice of Nondiscrimination Manage Cookies Advertising Mayo Clinic is a not-for-profit organization ...

  1. Ultrasound

    Science.gov (United States)

    ... reflect off body structures. A computer receives the waves and uses them to create a picture. Unlike with an x-ray or CT scan, this test does not use ionizing radiation. The test is done in the ultrasound ...

  2. The accuracy of musculoskeletal ultrasound examination for the exploration of meniscus injuries in athletes.

    Science.gov (United States)

    Mureşan, Simona; Mureşan, Mircea; Voidăzan, Septimiu; Neagoe, Radu

    2017-05-01

    Meniscus injuries represent a frequently occurring pathology in athletes and require an optimum diagnosis protocol. This study aimed to evaluate the accuracy of ultrasound examination for the identification of meniscus injuries, in comparison with magnetic resonance imaging (MRI), using the arthroscopy as reference. This prospective longitudinal comparative study included 45 athletes who were clinically examined by MRI and further, by arthroscopy, in a medical center dedicated to sport traumatology. The conventional ultrasound exploration of the knee allowed the identification of a diverse pathology, presenting a sensitivity of 88.8% for the diagnosis of medial meniscus injuries and 70.0% for the lateral meniscus. The specificity was 77.7% for the medial meniscus and 96.0% for the identification of lateral meniscus injuries. Using MRI, a sensitivity of 69.4% was obtained for the medial meniscus and 75.0% for the lateral meniscus, with a specificity of 76.6% for the pathology of medial meniscus and 80.0% for the lateral meniscus. Statistical analysis, based on the comparison of ROC curves, did not show any significant difference between the two applied diagnostic techniques (P=0.061 for the medial meniscus and P=0.534 for the lateral meniscus). The musculoskeletal ultrasound exploration of the knee joint, performed in a medical center with high addressability, by an experienced examiner, was able to identify the medial and lateral meniscus injuries with an accuracy comparable to that of MRI examination.

  3. Ultrasound and Histologic Examination after Subcutaneous Injection of Two Volumizing Hyaluronic Acid Fillers: A Preliminary Study

    Science.gov (United States)

    Besse, Stéphanie; Sarazin, Didier; Quinodoz, Pierre; Elias, Badwi; Safa, Marva; Vandeputte, Joan

    2017-01-01

    Background: This study examined the influence of hyaluronic acid (HA) crosslinking technology on the ultrasound and histologic behavior of HA fillers designed for subcutaneous injection. Methods: One subject received subcutaneous injections of 0.25 ml Cohesive Polydensified Matrix (CPM) and Vycross volumizing HA in tissue scheduled for abdominoplasty by bolus and retrograde fanning techniques. Ultrasound analyses were performed on days 0 and 8 and histologic analyses on days 0 and 21 after injection. A series of simple rheologic tests was also performed. Results: Day 0 ultrasound images after bolus injection showed CPM and Vycross as hypoechogenic papules in the hypodermis. CPM appeared little changed after gentle massage, whereas Vycross appeared more hyperechogenic and diminished in size. Ultrasound images at day 8 were similar. On day 0, both gels appeared less hypoechogenic after retrograde fanning than after bolus injection. Vycross was interspersed with hyperechogenic areas (fibrous septa from the fat network structure) and unlike CPM became almost completely invisible after gentle massage. On day 8, CPM appeared as a hypoechogenic pool and Vycross as a long, thin rod. Day 0 histologic findings confirmed ultrasound results. Day 21 CPM histologic findings showed a discrete inflammatory reaction along the injection row after retrograde fanning. Vycross had a more pronounced inflammatory reaction, particularly after retrograde fanning, with macrophages and giant cells surrounding the implant. Rheologic tests showed CPM to have greater cohesivity and resistance to traction forces than Vycross. Conclusions: CPM HA volumizer appears to maintain greater tissue integrity than Vycross after subcutaneous injection with less inflammatory activity. PMID:28280664

  4. A comparison of physical examinations with musculoskeletal ultrasound in the diagnosis of biceps long head tendinitis.

    Science.gov (United States)

    Chen, Hung-Sheng; Lin, Shu-Hsien; Hsu, Yen-Hsia; Chen, Shih-Ching; Kang, Jiunn-Horng

    2011-09-01

    Provocative tests are useful in diagnosing biceps tendon tendinitis. This is the first study to establish the reliability of these tests by comparing the resuts with musculoskeletal ultrasound (US) findings. This study examined 125 patients (69 women and 56 men) and 143 shoulders with shoulder pain. Yergason's test, Speed's test and a bicipital groove tenderness test were performed and musculoskeletal US findings were used as standard reference. Biceps tendon tendinitis was diagnosed with US in 39.1% of the patients and, of those, 55.3% had coexisting rotator cuff injury. The sensitivity and specificity of Yergason's test were 32% and 78%, respectively. The sensitivity and specificity of Speed's test were 63% and 58%, respectively. In conclusion, all three tests are limited by poor sensitivity. US can be an image modality choice in diagnosing biceps pathology. Copyright © 2011 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.

  5. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... a pelvic ultrasound examination. Doppler ultrasound , also called color Doppler ultrasonography, is a special ultrasound technique that ... and processes the sounds and creates graphs or color pictures that represent the flow of blood through ...

  6. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... Ultrasound imaging is a noninvasive medical test that helps physicians diagnose and treat medical conditions. There are ... Ultrasound page for more information . Ultrasound examinations can help diagnose symptoms experienced by women such as: pelvic ...

  7. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... ultrasound images are captured in real-time, they can show the structure and movement of the body's ... Obstetrical Ultrasound page for more information . Ultrasound examinations can help diagnose symptoms experienced by women such as: ...

  8. Breast Ultrasound Examination with Video Monitor System: A Satisfaction Survey among Patients

    Energy Technology Data Exchange (ETDEWEB)

    Ryu, Jung Kyu; Kim, Hyun Cheol; Yang, Dal Mo [East-West Neo Medical Center, Kyung-Hee University, Seoul (Korea, Republic of)

    2010-03-15

    The purpose of this study is to assess the patients satisfaction with a newly established video-monitor system and the associated basic items for performing breast ultrasound exams by conducting a survey among the patients. 349 patients were invited to take the survey and they had undergone breast ultrasound examination once during the 3 months after the monitor system has been introduced. The questionnaire was composed of 8 questions, 4 of which were about the basic items such as age, gender and the reason of their taking the breast ultrasound exam, their preference for the gender of the examiner and the desired length of time for the examination. The other 4 question were about their satisfaction with the video monitor. The patients were divided into two groups according to the purposes of taking the exams, which were screening or diagnostic purposes. The results were compared between these 2 groups. The satisfaction with the video monitor system was assessed by using a scoring system that ranged from 1 to 5. For the total patients, the screening group was composed of 124 patients and the diagnostic group was composed of 225. The reasons why the patients wanted to take the examinations in the diagnostic group varied. The questionnaire about the preference of the gender of the examiner showed that 81.5% in the screening group and 79.1% in the diagnostic group preferred a woman doctor. The required, suitable time for the breast ultrasound examination was 5 to 10 minutes or 10 to 15 minutes for about 70% of the patients. The mean satisfaction score for the video monitor system was as high as 3.95 point. The portion of patients in each group who answered over 3 points for their satisfaction with the monitor system was 88.7% and 94.2%, respectively. Our study showed that patients preferred 5-15 minutes for the length of the examination time and a female examiner. We also confirmed high patient satisfaction with the video monitor system

  9. Breast Ultrasound Examination with Video Monitor System: A Satisfaction Survey among Patients

    International Nuclear Information System (INIS)

    Ryu, Jung Kyu; Kim, Hyun Cheol; Yang, Dal Mo

    2010-01-01

    The purpose of this study is to assess the patients satisfaction with a newly established video-monitor system and the associated basic items for performing breast ultrasound exams by conducting a survey among the patients. 349 patients were invited to take the survey and they had undergone breast ultrasound examination once during the 3 months after the monitor system has been introduced. The questionnaire was composed of 8 questions, 4 of which were about the basic items such as age, gender and the reason of their taking the breast ultrasound exam, their preference for the gender of the examiner and the desired length of time for the examination. The other 4 question were about their satisfaction with the video monitor. The patients were divided into two groups according to the purposes of taking the exams, which were screening or diagnostic purposes. The results were compared between these 2 groups. The satisfaction with the video monitor system was assessed by using a scoring system that ranged from 1 to 5. For the total patients, the screening group was composed of 124 patients and the diagnostic group was composed of 225. The reasons why the patients wanted to take the examinations in the diagnostic group varied. The questionnaire about the preference of the gender of the examiner showed that 81.5% in the screening group and 79.1% in the diagnostic group preferred a woman doctor. The required, suitable time for the breast ultrasound examination was 5 to 10 minutes or 10 to 15 minutes for about 70% of the patients. The mean satisfaction score for the video monitor system was as high as 3.95 point. The portion of patients in each group who answered over 3 points for their satisfaction with the monitor system was 88.7% and 94.2%, respectively. Our study showed that patients preferred 5-15 minutes for the length of the examination time and a female examiner. We also confirmed high patient satisfaction with the video monitor system

  10. Acute patellofemoral pain: aggravating activities, clinical examination, MRI and ultrasound findings

    DEFF Research Database (Denmark)

    Brushoj, C.; Holmich, P.; Nielsen, M.B.

    2008-01-01

    Objective: To investigate acute anterior knee pain caused by overuse in terms of pain location, aggravating activities, findings on clinical examination and ultrasound/MRI examination. To determine if acute anterior knee pain caused by overuse should be classified as a subgroup of patellofemoral......%)), but other synovial covered structures including the fat pad of Hoffa (12 patients (40%)), the medial plica and the joint line (12 patients (40%)) were also involved. Only eight patients (27%) experienced pain on the patellofemoral compression test. Only discrete changes was detected on MRI...

  11. Ultrasound Findings on Hands and Wrists of Patients with Systemic Lupus Erythematosus: Relationship with Physical Examination.

    Science.gov (United States)

    Lins, Carolina Freitas; Lima de Sá Ribeiro, Daniel; Dourado Santos, Willer Gonçalves; Rosa, Genevievi; Machicado, Viviane; Pedreira, Ana Luisa; Pimenta da Fonseca, Emanuela; Mota Duque Sousa, Anna Paula; Rodrigues Silva, Carla Baleeiro; Matos, Marcos Antonio Almeida; Santiago, Mittermayer Barreto

    2017-09-01

    Diagnosis of synovitis/tenosynovitis by physical examination can be difficult. Ultrasound (US) can be an effective tool for the evaluation of joint involvement in systemic lupus erythematosus (SLE). This study will describe musculoskeletal findings by US in SLE patients and the evaluation of their correlation with physical examination. SLE patients underwent clinical/sonographic evaluation of hand/wrists. In total, 896 joints were evaluated: at least 1 change on physical examination was found in 136 joints and at least 1 US abnormality was found in 65 of 896 joints. Out of the 65 joints with US changes, only 13 had findings on physical examination. Conversely, 111 joints had tenderness on physical examination with no sonographic abnormalities. Tenosynovitis was statistically significant more frequently with joint edema (41%) (p = 0.0003). US can detect musculoskeletal changes in only a minority of symptomatic SLE patients. Clinical findings may be related to some reasons that cannot be explained using US. Copyright © 2017 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.

  12. Examining Neosho madtom reproductive biology using ultrasound and artificial photothermal cycles

    Science.gov (United States)

    Bryan, J.L.; Wildhaber, M.L.; Noltie, Douglas B.

    2005-01-01

    We examined whether extended laboratory simulation of natural photothermal conditions could stimulate reproduction in the Neosho madtom Noturus placidus, a federally threatened species. For 3 years, a captive population of Neosho madtoms was maintained under simulated natural conditions and monitored routinely with ultrasound for reproductive condition. Female Neosho madtoms cycled in and out of spawning condition, producing and absorbing oocytes annually. Internal measurements made by means of ultrasound indicated the summer mean oocyte size remained consistent over the years, although estimated fecundity increased with increasing fish length. In the summer of 2001, after 3 years in the simulated natural environment, 13 out of 41 fish participated in 10 spawnings. Simulation of the natural photothermal environment, coupled with within-day temperature fluctuations during the spring rise, seemed important for the spawning of captive Neosho madtoms. The use of ultrasound to assess the reproductive status in Neosho madtoms was effective and resulted in negligible stress or injury to the fish. These procedures may facilitate future culture of this species and other madtoms Noturus spp., especially when species are rare, threatened, or endangered. ?? Copyright by the American Fisheries Society 2005.

  13. Frequency and number of ultrasound lung rockets (B-lines) using a regionally based lung ultrasound examination named vet BLUE (veterinary bedside lung ultrasound exam) in dogs with radiographically normal lung findings.

    Science.gov (United States)

    Lisciandro, Gregory R; Fosgate, Geoffrey T; Fulton, Robert M

    2014-01-01

    Lung ultrasound is superior to lung auscultation and supine chest radiography for many respiratory conditions in human patients. Ultrasound diagnoses are based on easily learned patterns of sonographic findings and artifacts in standardized images. By applying the wet lung (ultrasound lung rockets or B-lines, representing interstitial edema) versus dry lung (A-lines with a glide sign) concept many respiratory conditions can be diagnosed or excluded. The ultrasound probe can be used as a visual stethoscope for the evaluation of human lungs because dry artifacts (A-lines with a glide sign) predominate over wet artifacts (ultrasound lung rockets or B-lines). However, the frequency and number of wet lung ultrasound artifacts in dogs with radiographically normal lungs is unknown. Thus, the primary objective was to determine the baseline frequency and number of ultrasound lung rockets in dogs without clinical signs of respiratory disease and with radiographically normal lung findings using an 8-view novel regionally based lung ultrasound examination called Vet BLUE. Frequency of ultrasound lung rockets were statistically compared based on signalment, body condition score, investigator, and reasons for radiography. Ten left-sided heart failure dogs were similarly enrolled. Overall frequency of ultrasound lung rockets was 11% (95% confidence interval, 6-19%) in dogs without respiratory disease versus 100% (95% confidence interval, 74-100%) in those with left-sided heart failure. The low frequency and number of ultrasound lung rockets observed in dogs without respiratory disease and with radiographically normal lungs suggests that Vet BLUE will be clinically useful for the identification of canine respiratory conditions. © 2014 American College of Veterinary Radiology.

  14. Individual plant examination program aspirations and achievements

    International Nuclear Information System (INIS)

    Flack, J.H.

    1994-01-01

    An Individual Plant Examination (IPE) is a systematic examination of a nuclear power plant for vulnerabilities, or risk significant contributors. By mid 1994, all licensees of commercial nuclear power plants will have performed an IPE on their units. To date, the NRC staff has received sixty-three (80%) of the seventy-eight expected IPE submittals. Twelve IPE reviews are now complete, with twenty-two in various stages of review. This paper provides a preliminary overview and comparison of licensees IPEs to Commission objectives. Insights and findings stemming from the review program are also presented

  15. Novel Use of Ultrasound to Teach Reproductive System Physical Examination Skills and Pelvic Anatomy.

    Science.gov (United States)

    Parikh, Tejal; Czuzak, Maria; Bui, Naomi; Wildner, Corinna; Koch, Bryna; Leko, Elizabeth; Rappaport, William; Adhikari, Srikar; Gordon, Paul; Gura, Mike; Ellis, Susan

    2018-03-01

    To determine whether integration of ultrasound (US) into a reproductive system examination clinical skills lab can increase confidence in palpating key reproductive structures during testicular and bimanual pelvic examinations, reduce anxiety about conducting testicular and bimanual pelvic examinations, and improve performance on multiple-choice questions based on structure identification using US images. Second-year medical students enrolled in the Life Cycle preclinical course participated in this cross-sectional study. A single learning activity was developed to pair the teaching of the reproductive system physical examination with the use of US in the clinical skills lab. The evaluation of the teaching session consisted of a pre-post analysis of student self-reported knowledge, confidence, and anxiety. The response rate for the pre survey was 82% (n = 96), and the rate for the post survey was 79% (n = 93). Students' confidence in their ability to identify reproductive system structures on US images increased from pre to post survey. Their confidence in their ability to palpate the epididymis, uterus, and ovary during a physical examination improved, and their anxiety about conducting testicular and bimanual pelvic examinations decreased. Student satisfaction with the session was high. Students' performance on multiple-choice questions based on structure identification using US images was at 96% or higher. Our study findings support the integration of US into a reproductive system examination clinical skills lab. Medical students acquire competency and confidence in reproductive system physical examination skills with US integration. © 2017 by the American Institute of Ultrasound in Medicine.

  16. The role of the ultrasound examination in boy’s gynecomastia diagnosis

    Directory of Open Access Journals (Sweden)

    D. V. Akimov

    2012-01-01

    Full Text Available The research shows the results of the ultrasound examination of the 55 young patients suffering from gynecomastia. In the differential diag- nosis of true and false gynecomastia major differences were found in B-mode. The research of the vessel’s channels in the mammary gland’s tumor with the help of the color flow mapping and spectral Doppler is objectively convincing in a low proliferative activity of tumors. The pre- valence of the process didn’t influence the degree of vascularization and quantitative data of the blood flow.

  17. [Carpal canal ultrasound examination in patients with mild hand-arm vibration disease].

    Science.gov (United States)

    Liu, Y Z; Ye, Z H; Yang, W L; Zhu, J X; Lu, Q J; Su, W L

    2016-08-20

    Objective: To investigate the clinical value of ultrasound examination of carpal canal structure in patients with mild hand-arm vibration disease. Methods: A total of 29 patients (58 wrists) with mild hand-arm vibration disease who were treated in Shenzhen Prevention and Treatment Center for Occupational Diseases from May to December, 2015 were enrolled as observation group, and 20 healthy volunteers (40 wrists) were enrolled as the control group. Color Doppler ultrasound was used to observe the morphology and echo of the median nerve in the carpal canal and 9 muscle tendons and transverse carpal ligament. The thickness of transverse carpal ligament and diameter of the median nerve at the level of the hamulus of hamate bone were measured, as well as the cross-sectional area of the median nerve at the level of pisiform bone. Results: In the 29 patients with hand-arm vibration disease patients in the observation group, 8 experienced entrapment of the median nerve in the carpal canal, among whom 5 had entrapment in both wrists; there were 13 wrists (23%) with nerve entrapment and 45 wrists (77%) without nerve entrapment. Compared with the control group, the patients with hand-arm vibration disease and nerve entrapment in the observation group showed significant thickening of the transverse carpal ligament at the level of the hamulus of hamate bone and a significant increase in the cross-sectional area of the median nerve at the level of pisiform bone ( P 0.05) . Conclusion: Ultrasound examination can clearly show the radiological changes of carpal canal contents in patients with mild hand-arm vibration disease and has a certain diagnostic value in nerve damage in patients with hand-arm vibration disease.

  18. Pleural ultrasound as an adjunct to physical examination in the preoperative evaluation of lung cancer patients.

    Science.gov (United States)

    Bah, Ismaël; Goudie, Eric; Khereba, Mohamed; Ferraro, Pasquale; Duranceau, André; Martin, Jocelyne; Thiffault, Vicky; Liberman, Moishe

    2014-05-01

    Preoperative evaluation of patients with suspected or confirmed lung cancer consists of clinical and radiological staging. Malignant pleural effusion is a poor prognosticator in non-small-cell lung cancer. Pleural ultrasound (PU) allows for the assessment of pleural effusion, providing real-time guidance for its aspiration and cytological analysis. Pleural Ultrasonography in Lung Cancer (PULC) as an adjunct to physical examination has the potential to improve preoperative staging of non-small-cell lung cancer during first surgical encounter by allowing the evaluation of previously unassessed pleural effusion. This study consisted of a prospective trial of surgeon-performed PU in the preoperative evaluation of lung cancer patients. All patients evaluated in the thoracic surgery clinic with the new or presumed diagnosis of lung cancer were eligible. A portable ultrasound machine was used to evaluate pleural fluid in the bilateral costophrenic sulci with pleural fluid aspiration for cytological analysis. Forty-five patients were prospectively enrolled over a 3-month period. Thirteen patients had ultrasound evidence of a pleural effusion, of which 3 were significant enough for aspiration. Cytological analysis of these effusions yielded malignant cells in 1 patient. Positive PULC evaluation led to a change in clinical staging (M0 to M1a) in 10 patients and a change in pathological staging (pleural fluid cytology positive) in 1 patient. The time required for PULC examination was 15 ± 7 min. There were no complications related to the procedures. Preoperative pleural ultrasonography is a rapid and effective way to improve precision of staging in patients with lung cancer. More precise staging may allow for more appropriate testing, patient prognostication and operative planning.

  19. Non-thrombotic Abnormalities on Lower Extremity Venous Duplex Ultrasound Examinations

    Directory of Open Access Journals (Sweden)

    Adhikari, Srikar

    2015-03-01

    Full Text Available Introduction: Emergency physician-performed compression ultrasonography focuses primarily on the evaluation of the proximal veins of the lower extremity in patients with suspected deep venous thrombosis (DVT. A detailed sonographic evaluation of lower extremity is not performed. The objective of this study was to determine the prevalence of non-thrombotic findings on comprehensive lower extremity venous duplex ultrasound (US examinations performed on emergency department (ED patients. Methods: We performed a retrospective six-year review of an academic ED’s records of adult patients who underwent a comprehensive lower extremity duplex venous US examination for the evaluation of DVT. The entire US report was thoroughly reviewed for non-thrombotic findings. Results: We detected non-thrombotic findings in 263 (11%, 95% CI [9.5-11.9%] patients. Among the non-thrombotic findings, venous valvular incompetence (81, 30% was the most frequent, followed by cyst/mass (41, 15%, lymphadenopathy (33, 12%, phlebitis (12, 4.5%, hematoma (8, 3%, cellulitis (1, 0.3% and other (6, 2.2%. Conclusion: In our study, we detected a variety of non-thrombotic abnormalities on comprehensive lower extremity venous duplex US examinations performed on ED patients. Some of these abnormalities could be clinically significant and potentially be detected with point-of-care lower extremity US examinations if the symptomatic region is evaluated. In addition to assessment of the proximal veins for DVT, we recommend sonographic evaluation of the symptomatic area in the lower extremity when performing point-of-care ultrasound examinations to identify non-thrombotic abnormalities that may require immediate intervention or close follow up. [West J Emerg Med. 2015;16(2:250–254.

  20. Alternative Ultrasound Gel for a Sustainable Ultrasound Program: Application of Human Centered Design.

    Directory of Open Access Journals (Sweden)

    Margaret Salmon

    Full Text Available This paper describes design of a low cost, ultrasound gel from local products applying aspects of Human Centered Design methodology. A multidisciplinary team worked with clinicians who use ultrasound where commercial gel is cost prohibitive and scarce. The team followed the format outlined in the Ideo Took Kit. Research began by defining the challenge "how to create locally available alternative ultrasound gel for a low-resourced environment? The "End-Users," were identified as clinicians who use ultrasound in Democratic Republic of the Congo and Ethiopia. An expert group was identified and queried for possible alternatives to commercial gel. Responses included shampoo, oils, water and cornstarch. Cornstarch, while a reasonable solution, was either not available or too expensive. We then sought deeper knowledge of locally sources materials from local experts, market vendors, to develop a similar product. Suggested solutions gleaned from these interviews were collected and used to create ultrasound gel accounting for cost, image quality, manufacturing capability. Initial prototypes used cassava root flour from Great Lakes Region (DRC, Rwanda, Uganda, Tanzania and West Africa, and bula from Ethiopia. Prototypes were tested in the field and resulting images evaluated by our user group. A final prototype was then selected. Cassava and bula at a 32 part water, 8 part flour and 4 part salt, heated, mixed then cooled was the product design of choice.

  1. Alternative Ultrasound Gel for a Sustainable Ultrasound Program: Application of Human Centered Design.

    Science.gov (United States)

    Salmon, Margaret; Salmon, Christian; Bissinger, Alexa; Muller, Mundenga Mutendi; Gebreyesus, Alegnta; Geremew, Haimanot; Wendel, Sarah K; Wendell, Sarah; Azaza, Aklilu; Salumu, Maurice; Benfield, Nerys

    2015-01-01

    This paper describes design of a low cost, ultrasound gel from local products applying aspects of Human Centered Design methodology. A multidisciplinary team worked with clinicians who use ultrasound where commercial gel is cost prohibitive and scarce. The team followed the format outlined in the Ideo Took Kit. Research began by defining the challenge "how to create locally available alternative ultrasound gel for a low-resourced environment? The "End-Users," were identified as clinicians who use ultrasound in Democratic Republic of the Congo and Ethiopia. An expert group was identified and queried for possible alternatives to commercial gel. Responses included shampoo, oils, water and cornstarch. Cornstarch, while a reasonable solution, was either not available or too expensive. We then sought deeper knowledge of locally sources materials from local experts, market vendors, to develop a similar product. Suggested solutions gleaned from these interviews were collected and used to create ultrasound gel accounting for cost, image quality, manufacturing capability. Initial prototypes used cassava root flour from Great Lakes Region (DRC, Rwanda, Uganda, Tanzania) and West Africa, and bula from Ethiopia. Prototypes were tested in the field and resulting images evaluated by our user group. A final prototype was then selected. Cassava and bula at a 32 part water, 8 part flour and 4 part salt, heated, mixed then cooled was the product design of choice.

  2. Cytological endometritis and its agreement with ultrasound examination in postpartum beef cows

    Directory of Open Access Journals (Sweden)

    N. Salah

    2017-06-01

    Full Text Available Background: Endometritis, which is one of the most common diseases in dairy cows postpartum, causes severe economic losses, including increased open days, calving intervals, and numbers of services to achieve conception. Aim: This study aimed to evaluate the ultrasound method and its agreement with the endometrium cytology method, which is used to diagnose cytological endometritis in beef cows. Moreover, we determined which method has higher sensitivity and specificity at 4 and 5 weeks postpartum. Materials and Methods: The study was conducted 20-35 days postpartum. A total of 53 clinically healthy beef cows (28 Brangus and 25 Kedah-Kelantan breeds from three beef farms were obtained. All cows were evaluated at 4 and 5 weeks postpartum, using ultrasound and cytobrush endometrial examination methods to diagnose cytological endometritis. Results: Endometrial cytology result showed that 11.3% (6/53 and 9.4% (5/53 of the cows exhibited cytological endometritis 4 and 5 weeks postpartum, respectively. A weak-to-moderate agreement found between the diagnostic methods (k=0.29 - 0.50; p<0.01 and k=0.38 - 0.49 at 4 and 5 weeks postpartum respectively. Conclusion: The percentage of beef cows that were positive to cytological endometritis was low (polymorphonuclear cells, =8% at 4 and 5 weeks postpartum. Results showed that the ultrasound method is useful and practical for diagnosing endometritis 4 and 5 weeks postpartum. This method exhibited 60% sensitivity, 93.8% specificity, and a 0.50 kappa value, especially when presence of intrauterine fluids and measurement of cervix diameter used in combination.

  3. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... those sound waves to create an image. Ultrasound examinations do not use ionizing radiation (as used in ... ultrasound study may be part of an ultrasound examination. Doppler ultrasound , also called color Doppler ultrasonography, is ...

  4. Do we need a critical care ultrasound certification program? Implications from an Australian medical-legal perspective.

    Science.gov (United States)

    Huang, Stephen J; McLean, Anthony S

    2010-01-01

    Medical practitioners have a duty to maintain a certain standard of care in providing their services. With critical care ultrasound gaining popularity in the ICU, it is envisaged that more intensivists will use the tool in managing their patients. Ultrasound, especially echocardiography, can be an 'easy to learn, difficult to manage' skill, and the competency in performing the procedure varies greatly. In view of this, several recommendations for competency statements have been published in recent years to advocate the need for a unified approach to training and certification. In this paper, we take a slightly different perspective, from an Australian medical-legal viewpoint, to argue for the need to implement a critical care ultrasound certification program. We examine various issues that can potentially lead to a breach of the standard of care, hence exposing the practitioners and/or the healthcare institutions to lawsuits in professional negligence or breach of contract. These issues, among others, include the failure to use ultrasound in appropriate situations, the failure of hospitals to ensure practitioners are properly trained in the skills, the failure of practitioners to perform an ultrasound study that is of a reasonable standard, and the failure of practitioners to keep themselves abreast of the latest developments in treatment and management. The implications of these issues and the importance of having a certification process are discussed.

  5. Estimation of prenatal aorta intima-media thickness from ultrasound examination

    Science.gov (United States)

    Veronese, E.; Tarroni, G.; Visentin, S.; Cosmi, E.; Linguraru, M. G.; Grisan, E.

    2014-10-01

    of fetal aorta intima-media thickness from ultrasound examination', MICCAI Workshop on Perinatal and Paediatric Imaging: PaPI 2012.

  6. Ultrasound for internal medicine physicians: the future of the physical examination.

    Science.gov (United States)

    Dulohery, Megan M; Stoven, Samantha; Kurklinsky, Andrew K; Kurklinksy, Andrew; Halvorsen, Andrew; McDonald, Furman S; Bhagra, Anjali

    2014-06-01

    With the advent of compact ultrasound (US) devices, it is easier for physicians to enhance their physical examinations through the use of US. However, although this new tool is widely available, few internal medicine physicians have US training. This study sought to understand physicians' baseline knowledge and skill, provide education in US principles, and demonstrate that proper use of compact US devices is a skill that can be quickly learned. Training was performed at the Mayo Clinic in June 2010 and June 2011. The participants consisted of internal medicine residents. The workshop included didactics and hands-on US experiences with human and cadaver models in a simulation center. Pretests and posttests of residents' knowledge, attitudes, and skills with US were completed. We reassessed the 2010 group in the spring of 2012 with a long-term retention survey for knowledge and confidence in viewing images. A total of 136 interns completed the workshop. Thirty-nine residents completed the long-term retention survey. Posttest assessments showed a statistically significant improvement in the knowledge of US imaging, confidence in identifying structures, image identification, and image acquisition (P internal medicine training and practice. © 2014 by the American Institute of Ultrasound in Medicine.

  7. Is It Worthwhile to Fully Evaluate the Stomach in Every Ultrasound Examination of the Abdominal Cavity?

    International Nuclear Information System (INIS)

    Goudarzi, M.; Navabi, J.; Salimi, Gh.

    2011-01-01

    To evaluate the usefulness of abdominal sonography in the fasting state with no hypotonic agents in the detection and exclusion of gastric lesions. One-hundred patients with normal upper gastrointestinal endoscopy, 94 patients with a major gastric abnormality (including 59 intraluminal tumors, three submucosal masses, 29 ulcers, two polyps and one hypertrophied gastric mucosa) and 75 patients with minor gastric abnormalities (mainly gastritis) were enrolled into the study. Of the 100 normal patients, ultrasound showed four false positive results with 96% specificity of the examination. Within the major gastric lesion group, ultrasound was true positive in 55 of 59 tumors, 15 of 29 ulcers, three of three submucosal masses and the case of giant gastric mucosa. It was negative in the detection of gastric polyps. It could detect only 8% of minor gastric abnormalities. Abdominal sonography in the fasting state, if carefully performed, is sufficiently accurate in detection and exclusion of major gastric lesions. Therefore, although it cannot replace endoscopic and barium studies of the stomach, careful evaluation of the stomach is recommended in every sonographic evaluation of the abdominal cavity

  8. An Examination of New Counselor Mentor Programs

    Science.gov (United States)

    Bass, Erin; Gardner, Lauren; Onwukaeme, Chika; Revere, Dawn; Shepherd, Denise; Parrish, Mark S.

    2013-01-01

    An analysis of current new counselor mentor programs reveals the need for such programs, but information regarding established programs is limited. A review of the literature addresses program characteristics and data obtained from existing mentor program participants. An overview of four programs explaining the framework outlined for mentoring…

  9. Development and Implementation of an Ultrasound-Guided Peripheral Intravenous Catheter Program for Emergency Nurses.

    Science.gov (United States)

    Edwards, Courtney; Jones, Jodi

    2018-01-01

    Emergency medical care often necessitates placement of peripheral intravenous (PIV) catheters. When traditional methods for obtaining PIV access are not successful, ultrasound guidance is a rescue technique for peripheral vascular placement that improves the quality of patient care. The aim of this training program was to develop a process where emergency nurses would be competent to perform ultrasound guided PIV to improve the quality of patient care delivered while reducing throughput time. Administrative program development required creating a nursing practice statement, procedure guideline, operational plan, and competency validation. A training program comprising both didactic and hands-on training was developed and provided by emergency medicine physicians with formal ultrasound fellowship training. In determining whether the training program was adequate in preparing the student to place an ultrasound-guided PIV, 92.9% of students "agreed" or "strongly agreed." In having confidence in their ability to obtain an ultrasound guided PIV catheter placement, 35.7% of respondents "agreed" and 64.3% "strongly agreed." In finding it difficult to be successful in achieving ultrasound guided PIV catheter placement, 71.4% of students "strongly disagreed" and 14.3% "disagreed." All students (100%) felt it was a feasible task to train nurses to successfully place ultrasound-guided PIV catheters and 71.4% of students strongly support continuing to provide this training program and competency validation. Establishment of an effective didactic and hands-on training program resulted in emergency department nurses becoming competent in placement of ultrasound guided PIV catheters to provide optimal patient care. Copyright © 2017 Emergency Nurses Association. Published by Elsevier Inc. All rights reserved.

  10. Adding ultrasound to clinical examination reduced frequency of enthesitis in primary care psoriasis patients with musculoskeletal complaints.

    Science.gov (United States)

    van der Ven, Myrthe; Karreman, Maren C; Weel, Angelique E A M; Tchetverikov, Ilja; Vis, Marijn; Nijsten, Tamar E C; Hazes, Johanna M W; Luime, Jolanda J

    2016-01-01

    Part of the psoriasis patients with musculoskeletal complaints will have inflammation of the entheses. Entheseal inflammation is difficult to assess by clinical examination only. Therefore, we aimed to determine the frequency of clinically relevant ultrasound inflammation at the most commonly assessed entheses (MASEI; Madrid Sonographic Enthesis Index) in primary care psoriasis patients with one or more tender entheses. Adult primary care psoriasis patients with musculoskeletal complaints (tender enthesis or arthritis at physical examination) had an ultrasound examination of seven entheses according to the MASEI. Clinically relevant ultrasound inflammation was defined as active inflammation on ultrasound in combination with at least one clinical feature at the same enthesis. Active ultrasound inflammation contained positive power Doppler signal or in case of the plantar aponeurosis increased thickness. Structural changes entailed calcifications, enthesophytes, increased thickness, hypoechogeneicity indicating irregular fibre structure and erosions. Clinically, an enthesis was scored positive by a tender enthesis at clinical examination, reported pain in the history or self-reported pain in the questionnaires. Of 542 primary care psoriasis patient, 111 patients had tender entheses and/or arthritis. These patients were both clinically and ultrasonographically evaluated. Active ultrasound inflammation accompanied with pain or tenderness at the enthesis was found in 36% of the patients (n=40). Most common were inflammation at the knee (n=11) and at the plantar aponeurosis (n=10). Structural changes were observed in 95% of the psoriasis patients independent of their clinical manifestation. We found concurrent presence of ultrasound inflammatory changes and clinical symptoms in 36% of the primary care psoriasis patients who had tenderness at one or more entheseal sites.

  11. Does Ultrasound-Enhanced Instruction of Musculoskeletal Anatomy Improve Physical Examination Skills of First-Year Medical Students?

    Science.gov (United States)

    Walrod, Bryant J; Schroeder, Allison; Conroy, Mark J; Boucher, Laura C; Bockbrader, Marcia; Way, David P; McCamey, Kendra L; Hartz, Clinton A; Jonesco, Michael A; Bahner, David P

    2018-01-01

    Ultrasound imaging is commonly used to teach basic anatomy to medical students. The purpose of this study was to determine whether learning musculoskeletal anatomy with ultrasound improved performance on medical students' musculoskeletal physical examination skills. Twenty-seven first-year medical students were randomly assigned to 1 of 2 instructional groups: either shoulder or knee. Both groups received a lecture followed by hands-on ultrasound scanning on live human models of the assigned joint. After instruction, students were assessed on their ability to accurately palpate 4 anatomic landmarks: the acromioclavicular joint, the proximal long-head biceps tendon, and the medial and lateral joint lines of the knee. Performance scores were based on both accuracy and time. A total physical examination performance score was derived for each joint. Scores for instructional groups were compared by a 2-way analysis of variance with 1 repeated measure. Significant findings were further analyzed with post hoc tests. All students performed significantly better on the knee examination, irrespective of instructional group (F = 14.9; df = 1.25; P = .001). Moreover, the shoulder instruction group performed significantly better than the knee group on the overall assessment (t = -3.0; df = 25; P soft tissue landmark. Both groups performed similarly on palpation of all other anatomic structures. The use of ultrasound appears to provide an educational advantage when learning musculoskeletal physical examination of soft tissue landmarks. © 2017 by the American Institute of Ultrasound in Medicine.

  12. Prostate Ultrasound

    Medline Plus

    Full Text Available ... those sound waves to create an image. Ultrasound examinations do not use ionizing radiation (as used in ... abnormal masses, such as tumors. In an ultrasound examination, a transducer both sends the sound waves into ...

  13. Preprocedural ultrasound examination versus manual palpation for thoracic epidural catheter insertion

    Directory of Open Access Journals (Sweden)

    Ahmed M Hasanin

    2017-01-01

    Conclusion: Preprocedural ultrasound imaging increased the incidence of first pass success in thoracic epidural catheter insertion and reduced the catheter insertion time compared to manual palpation method.

  14. Usefulness of ultrasound examination in the evaluation of a neonate's body fluid status.

    Science.gov (United States)

    Kieliszczyk, Joanna; Baranowski, Wojciech; Kosiak, Wojciech

    2016-06-01

    Appropriate hydration is a very important prognostic factor for the patient's health. Ultrasonographic assessment of hydration status is rarely used in pediatric medicine and it is not used at all in neonates due to the fact that no reference values have been established for this age group. The aim of the paper was to establish reference values for neonates. The study included 50 neonates from two hospitals in the Lower Silesia region of Poland; 25 of them were healthy patients (full-term newborns with no perinatal complications) and 25 were sick patients (newborns with heart defects such as ostium secundum atrial septal defect, ventricular septal defect, permanent foramen ovale and patent ductus arteriosus as well as newborns with neonatal jaundice or pneumonia that occurred during the first days of life). The ultrasound scans were conducted during the first days of the children's life. For every child inferior vena cava diameter was measured in the substernal area, longitudinal plane, M-mode in two respiratory phases: inhalation and exhalation. In addition, abdominal aorta diameter was determined (substernal area, transverse plane). The study demonstrated a statistically significant difference in the calculated inferior vena cava collapsibility index between both groups. Two other indices included the ratio of the inferior vena cava diameter during the expiratory phase to the diameter of the aorta and the ratio of the inferior vena cava diameter during the inspiratory phase to the diameter of the aorta; a statistically significant difference between both groups was found only for the measurements in the inspiratory phase. Based on the study results normal ranges for hydration indices in neonates were established. The need for the measurement of the abovementioned parameters in the inspiratory phase was determined. In addition, the usefulness of the ultrasound examination for the evaluation of body fluid status in this pediatric age group, particularly in preterm

  15. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... of an ultrasound examination. Doppler ultrasound , also called color Doppler ultrasonography, is a special ultrasound technique that ... kidneys. There are three types of Doppler ultrasound: Color Doppler uses a computer to convert Doppler measurements ...

  16. Quality Assessment of Hepatic Ultrasound Images Examined After a Medical Check-up

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Pyo Nyun; Kim, Kyung Won; Byun, Jae Ho [University of Ulsan College of Medicine, Asan Medical Center, Seoul (Korea, Republic of)

    2009-03-15

    This study was designed to determine problems associated with liver ultrasonography for healthy individuals after a medical examination by the evaluation of sonographic images. A total of 353 patients randomly selected from 341 institutions underwent liver ultrasonography. Among the patients, 14 patients were excluded from the study as they possessed digital images that were not accessible (n = 10) or underwent ultrasonography (n = 4) that did not involve the liver. Two experts each with a ten-year experience in the interpretation of ultrasonography analyzed the images with consensus based on the assessment of liver ultrasonography established by the Korean Society of Ultrasound in Medicine. The images of 339 patients consisted of digital images (n =135), films (n = 14) and prints on paper (n = 190). A total of 3514 images (range, 1-39: mean number of images per patient,10.4) were obtained from 339 patients. Of the patients, there were 232 (68.4%) patients with eight good images and 231 patients had a score greater than 60 points. The mean percent score was 64.9 for general information, 63.8 for technical information and 50.5 for a standard examination. The mean percent score for a longitudinal scan of the common bile duct and vertical scan of the left lobe were low at 20.1 and 28.9, respectively. The number of good images was sufficient at 10.4, but patient information was not exact, ultrasonographic equipment was not adjusted and a standard examination was not applied. As these findings were based on examiner ignorance and indifference, education or certification for examiners should be required

  17. Quality Assessment of Hepatic Ultrasound Images Examined After a Medical Check-up

    International Nuclear Information System (INIS)

    Kim, Pyo Nyun; Kim, Kyung Won; Byun, Jae Ho

    2009-01-01

    This study was designed to determine problems associated with liver ultrasonography for healthy individuals after a medical examination by the evaluation of sonographic images. A total of 353 patients randomly selected from 341 institutions underwent liver ultrasonography. Among the patients, 14 patients were excluded from the study as they possessed digital images that were not accessible (n = 10) or underwent ultrasonography (n = 4) that did not involve the liver. Two experts each with a ten-year experience in the interpretation of ultrasonography analyzed the images with consensus based on the assessment of liver ultrasonography established by the Korean Society of Ultrasound in Medicine. The images of 339 patients consisted of digital images (n =135), films (n = 14) and prints on paper (n = 190). A total of 3514 images (range, 1-39: mean number of images per patient,10.4) were obtained from 339 patients. Of the patients, there were 232 (68.4%) patients with eight good images and 231 patients had a score greater than 60 points. The mean percent score was 64.9 for general information, 63.8 for technical information and 50.5 for a standard examination. The mean percent score for a longitudinal scan of the common bile duct and vertical scan of the left lobe were low at 20.1 and 28.9, respectively. The number of good images was sufficient at 10.4, but patient information was not exact, ultrasonographic equipment was not adjusted and a standard examination was not applied. As these findings were based on examiner ignorance and indifference, education or certification for examiners should be required

  18. Agreement Between an Automated Volume Breast Scanner and Handheld Ultrasound for Diagnostic Breast Examinations.

    Science.gov (United States)

    Barr, Richard G; DeVita, Robert; Destounis, Stamatia; Manzoni, Federica; De Silvestri, Annalisa; Tinelli, Carmine

    2017-10-01

    To compare the agreement and interobserver variability of diagnostic handheld ultrasound (US) and a single volume on an automated breast volume scanner (ABVS) and to determine whether there was a significant difference if the ABVS was used by a sonographer or mammographic technologist. Ninety patients scheduled for diagnostic US examinations were randomized to either handheld US or the ABVS first. The AVBS was randomized between a sonographer and a mammographic technologist performing the study. The studies were blinded, randomized, and read by 2 radiologists. The lesion with the highest Breast Imaging Reporting and Data System (BI-RADS) score was used in the analysis. Final diagnoses were made by core biopsy or follow-up for 2 years. Lesions included 9 malignant and 81 benign. The 90 patients had a mean age ± SD of 53.1 ± 16.3 years. The κ value for agreement between the ABVS and handheld US was 0.831 (95% confidence interval, 0.744-0.925), whereas the global agreement for a 7-point BI-RADS score was 0.488 (0.372-0.560). The agreement between the ABVS and handheld US was nearly the same when the ABVS was used by a mammographic technologist (κ = 0.858 [0.723-0.963]) or sonographer (κ = 0.803 [0.596-1.000]; P = .47). The areas under the receiver operating characteristic curves for characterization by the ABVS were 0.91 (0.84-0.96) for reader 1 and 0.91 (0.83-0.96) for reader 2; those for handheld US were 0.91 (0.84-0.96) for reader 1 and 0.83 (0.74-0.90) for reader 2, with no statistical difference. The agreement based on pathologic images was κ = 0.831 (0.718-0.944); for handheld US, κ = 0.795 (0.623-0.967); and for the AVBS, κ = 0.869 (0.725-1.000). Performing a single-view diagnostic ABVS examination has good agreement with a handheld diagnostic US workup. There is no difference if the ABVS is used by a sonographer or mammographic technologist. © 2017 by the American Institute of Ultrasound in Medicine.

  19. Examining Burma's Development: A Research Fellowship Program ...

    International Development Research Centre (IDRC) Digital Library (Canada)

    The Regional Center for Social Science and Sustainable Development (RCSD) at Thailand's Chiang Mai University will manage the four-year program, which targets junior and mid-level academic and non-academic Burmese scholars. The program will ... LVIF announces five more funded projects. Eleven world-class ...

  20. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... image. Ultrasound examinations do not use ionizing radiation (as used in x-rays ), thus there is no ... structure and movement of the body's internal organs, as well as blood flowing through blood vessels. Ultrasound ...

  1. Prostate Ultrasound

    Medline Plus

    Full Text Available ... of page What will I experience during and after the procedure? Ultrasound exams in which the transducer ... in the sperm or urine following the procedure. After an ultrasound examination, you should be able to ...

  2. Prostate Ultrasound

    Medline Plus

    Full Text Available ... Ultrasound is safe, noninvasive, and does not use ionizing radiation. This procedure requires little to no special preparation. ... create an image. Ultrasound examinations do not use ionizing radiation (as used in x-rays ), thus there is ...

  3. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... Ultrasound is safe, noninvasive and does not use ionizing radiation. This procedure requires little to no special preparation. ... create an image. Ultrasound examinations do not use ionizing radiation (as used in x-rays ), thus there is ...

  4. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... most ultrasound exams, you will be positioned lying face-up on an examination table that can be ... region of the prostate. A biopsy will add time to the procedure. If a Doppler ultrasound study ...

  5. Prostate specific antigen, digital rectal examination, transrectal ultrasound: how accurate are they in determining prostate carcinoma?

    International Nuclear Information System (INIS)

    Gomez, John Anthony M.; Pagdanganan, Ernest Jerome A.; Caedo, Florencio Gerardo O.; Magsino, Benjamin C.; Rivera, Eduardo Ll.; Songco, Jaime S.D.

    1998-01-01

    Prostate cancer is an increasing problem. It is the most frequent malignancy in men past the age of 65 years. In the Philippines, 10-20% of males operated for prostatic obstruction had prostate cancer. The potential for cure is optimized by early detection and treatment of organ confined disease. Digital rectal examination, serum prostatic specific antigen and transrectal ultrasound of the prostate have been advocated individually and collectively to determine prostatic cancer. Our study involved forty-nine males who underwent all three screening modalities. Results of the study showed a statistically significant association between the presence of a nodule and occurrence of prostate cancer, a statistically significant association between hardness in consistency and cancer, a statistically significant difference in mean weight between those with Ca and BPH; a statistically significant difference in mean PSA levels between those with Ca and with BPH; statistically significant association between abnormal PSA levels and Ca; and a statistically significant association between a composite positive result and cancer. On the other hand, there was no statistically significant difference in mean age between those with cancer and those with BPH; there is no statistically significant association between the presence of prostatism and whether the patient has Ca or BPH; and there is no statistically significant difference in the mean duration between those with cancer and those with BPH. The study advocates the use of DRE, serum PSA in determining prostatic Ca as well as TRUS for determining occult carcinoma. (Author)

  6. Usefulness of ultrasound examination in the evaluation of a neonate’s body fluid status

    Directory of Open Access Journals (Sweden)

    Joanna Kieliszczyk

    2016-06-01

    Full Text Available Appropriate hydration is a very important prognostic factor for the patient’s health. Ultrasonographic assessment of hydration status is rarely used in pediatric medicine and it is not used at all in neonates due to the fact that no reference values have been established for this age group. The aim of the paper was to establish reference values for neonates. Material and methods: The study included 50 neonates from two hospitals in the Lower Silesia region of Poland; 25 of them were healthy patients (full-term newborns with no perinatal complications and 25 were sick patients (newborns with heart defects such as ostium secundum atrial septal defect, ventricular septal defect, permanent foramen ovale and patent ductus arteriosus as well as newborns with neonatal jaundice or pneumonia that occurred during the first days of life. The ultrasound scans were conducted during the first days of the children’s life. For every child inferior vena cava diameter was measured in the substernal area, longitudinal plane, M-mode in two respiratory phases: inhalation and exhalation. In addition, abdominal aorta diameter was determined (substernal area, transverse plane. Results: The study demonstrated a statistically significant difference in the calculated inferior vena cava collapsibility index between both groups. Two other indices included the ratio of the inferior vena cava diameter during the expiratory phase to the diameter of the aorta and the ratio of the inferior vena cava diameter during the inspiratory phase to the diameter of the aorta; a statistically significant difference between both groups was found only for the measurements in the inspiratory phase. Conclusions: Based on the study results normal ranges for hydration indices in neonates were established. The need for the measurement of the abovementioned parameters in the inspiratory phase was determined. In addition, the usefulness of the ultrasound examination for the evaluation of body

  7. Comparison the percentage of detection of periarthritis in patients with rheumatoid arthritis using clinical examination or ultrasound methods

    OpenAIRE

    Hadi Karimzadeh; Zahra Seyedbonakdar; Maryam Mousavi; Mehdi Karami

    2016-01-01

    Background: This study aimed to compare the percentage of detection of periarthritis in patients with rheumatoid arthritis using clinical examination and ultrasound methods. Materials and Methods: This study is a cross-sectional study which was conducted in Al-Zahra Hospital (Isfahan, Iran) during 2014?2015. In our study, ninety patients were selected based on the American College of Rheumatology 2010 criteria. All patients were examined by a rheumatologist to find the existence of effusion, ...

  8. Transjugular Intrahepatic Portosystemic Shunt Dysfunction: Concordance of Clinical Findings, Doppler Ultrasound Examination, and Shunt Venography.

    Science.gov (United States)

    Owen, Joshua M; Gaba, Ron Charles

    2016-01-01

    The objective of this study was to evaluate the concordance between clinical symptoms, Doppler ultrasound (US), and shunt venography for the detection of stent-graft transjugular intrahepatic portosystemic shunt (TIPS) dysfunction. Forty-one patients (M:F 30:11, median age 55 years) who underwent contemporaneous clinical exam, Doppler US, and TIPS venography between 2003 and 2014 were retrospectively studied. Clinical symptoms (recurrent ascites or variceal bleeding) were dichotomously classified as present/absent, and US and TIPS venograms were categorized in a binary fashion as normal/abnormal. US abnormalities included high/low (>190 or 50 cm/s), absent flow, and return of antegrade intra-hepatic portal flow. Venographic abnormalities included shunt stenosis/occlusion and/or pressure gradient elevation. Clinical and imaging concordance rates were calculated. Fifty-two corresponding US examinations and venograms were assessed. The median time between studies was 3 days. Forty of 52 (77%) patients were symptomatic, 33/52 (64%) US examinations were abnormal, and 20/52 (38%) TIPS venograms were abnormal. Concordance between clinical symptoms and TIPS venography was 48% (25/52), while the agreement between US and shunt venography was 65% (34/52). Clinical symptoms and the US concurred in 60% (31/52) of the patients. The sensitivity of clinical symptoms and US for the detection of venographically abnormal shunts was 80% (16/20) and 85% (17/20), respectively. Both clinical symptoms and the US had low specificity (25%, 8/32 and 50%, 16/32) for venographically abnormal shunts. Clinical findings and the US had low concordance rates with TIPS venography, with acceptable sensitivity but poor specificity. These findings suggest the need for improved noninvasive imaging methods for stent-graft TIPS surveillance.

  9. Transjugular Intrahepatic Portosystemic Shunt Dysfunction: Concordance of Clinical Findings, Doppler Ultrasound Examination, and Shunt Venography

    Directory of Open Access Journals (Sweden)

    Joshua M Owen

    2016-01-01

    Full Text Available Objectives: The objective of this study was to evaluate the concordance between clinical symptoms, Doppler ultrasound (US, and shunt venography for the detection of stent-graft transjugular intrahepatic portosystemic shunt (TIPS dysfunction. Materials and Methods: Forty-one patients (M:F 30:11, median age 55 years who underwent contemporaneous clinical exam, Doppler US, and TIPS venography between 2003 and 2014 were retrospectively studied. Clinical symptoms (recurrent ascites or variceal bleeding were dichotomously classified as present/absent, and US and TIPS venograms were categorized in a binary fashion as normal/abnormal. US abnormalities included high/low (>190 or 50 cm/s, absent flow, and return of antegrade intra-hepatic portal flow. Venographic abnormalities included shunt stenosis/occlusion and/or pressure gradient elevation. Clinical and imaging concordance rates were calculated. Results: Fifty-two corresponding US examinations and venograms were assessed. The median time between studies was 3 days. Forty of 52 (77% patients were symptomatic, 33/52 (64% US examinations were abnormal, and 20/52 (38% TIPS venograms were abnormal. Concordance between clinical symptoms and TIPS venography was 48% (25/52, while the agreement between US and shunt venography was 65% (34/52. Clinical symptoms and the US concurred in 60% (31/52 of the patients. The sensitivity of clinical symptoms and US for the detection of venographically abnormal shunts was 80% (16/20 and 85% (17/20, respectively. Both clinical symptoms and the US had low specificity (25%, 8/32 and 50%, 16/32 for venographically abnormal shunts. Conclusion: Clinical findings and the US had low concordance rates with TIPS venography, with acceptable sensitivity but poor specificity. These findings suggest the need for improved noninvasive imaging methods for stent-graft TIPS surveillance.

  10. Remote just-in-time telementored trauma ultrasound: a double-factorial randomized controlled trial examining fluid detection and remote knobology control through an ultrasound graphic user interface display.

    Science.gov (United States)

    Kirkpatrick, Andrew W; McKee, Ian; McKee, Jessica L; Ma, Irene; McBeth, Paul B; Roberts, Derek J; Wurster, Charles L; Parfitt, Robbie; Ball, Chad G; Oberg, Scott; Sevcik, William; Hamilton, Douglas R

    2016-05-01

    Remote-telementored ultrasound involves novice examiners being remotely guided by experts using informatic-technologies. However, requiring a novice to perform ultrasound is a cognitively demanding task exacerbated by unfamiliarity with ultrasound-machine controls. We incorporated a randomized evaluation of using remote control of the ultrasound functionality (knobology) within a study in which the images generated by distant naive examiners were viewed on an ultrasound graphic user interface (GUI) display viewed on laptop computers by mentors in different cities. Fire-fighters in Edmonton (101) were remotely mentored from Calgary (n = 65), Nanaimo (n = 19), and Memphis (n = 17) to examine an ultrasound phantom randomized to contain free fluid or not. Remote mentors (2 surgeons, 1 internist, and 1 ED physician) were randomly assigned to use GUI knobology control during mentoring (GUIK+/GUIK-). Remote-telementored ultrasound was feasible in all cases. Overall accuracy for fluid detection was 97% (confidence interval = 91 to 99%) with 3 false negatives (FNs). Positive/negative likelihood ratios were infinity/0.0625. One FN occurred with the GUIK+ and 2 without (GUIK-). There were no statistical test performance differences in either group (GUIK+ and GUIK-). Ultrasound-naive 1st responders can be remotely mentored with high accuracy, although providing basic remote control of the knobology did not affect outcomes. Copyright © 2016 Elsevier Inc. All rights reserved.

  11. Diagnostic possibilities of ultrasound examination and diuretic nephrography (Furosemide test F +20) to evaluate hydronephrosis in children

    International Nuclear Information System (INIS)

    Boueva, A.; Palashev, J.; Mlachkov, N.

    2005-01-01

    The aim of this study is to compare diagnostic value of kidney ultrasound examination (US) and diuretic nephrography (furosemide test F+20) for assessment of the kind and degree of obstructive renal changes in childhood. 12 children (8 girls and 4 boys; mean age 4.4 years) with observation of congenital hydronephrosis were examined. Diuretic 99mTc-EC nephrography (F+20) with SPECT gamma camera STARCAM 40001 (General Electric) was done. The results of 99mTc-EC Diuretic nephrography (F+20) were as follows: positive furosemide test (F+20) in ten children (seven girls and tree boys) 83.3% and no found dynamic changes in drainage after (F+20) in 2 children (one girl and one boy) 16.7%. Correlation between ultrasound examination and Diuretic nephrography 99mTcEC (F+20) for the diagnosis hydronephrosis was 100 %. The ultrasound examination and 99mTc-EC Diuretic nephrography (F+20) are highly informative and suitable methods for assessment kind and degree of hydronephrosis in children. The combination of two methods allows a possibility of differentiation of the type of obstruction - functional or organic etiology

  12. Severity Stratification by Compression Ultrasound Examination in Lipodermatosclerosis and Diabetic Dermopathy Patients: a Report of Three Cases

    Directory of Open Access Journals (Sweden)

    Podoleanu Cristian

    2017-06-01

    Full Text Available Lipodermatosclerosis and diabetic dermopathy are low-risk skin lesions with many similar clinical features, except for venous abnormalities such as chronic venous insufficiency, but are rarely a reason for referring the patient to vascular ultrasound examination. We present 3 serial cases in which the compression ultrasound examination (CUS of the venous circulation of the affected limbs was of utmost importance in the severity stratification. Asymptomatic deep venous thrombosis (DVT was found in the first two cases, while in the third case the CUS excluded any type of vascular involvement, leading to a definite diagnosis of diabetic dermopathy. Lipodermatosclerosis may be associated with asymptomatic DVT due to chronic venous insufficiency, and early referral to CUS positively impacts further patient management.

  13. Baseline ultrasound examination as possible predictor of relapse in patients affected by juvenile idiopathic arthritis (JIA).

    Science.gov (United States)

    De Lucia, Orazio; Ravagnani, Viviana; Pregnolato, Francesca; Hila, Arvena; Pontikaki, Irene; Gattinara, Maurizio; Romano, Micol; Gerloni, Valeria; Pieropan, Sara; Murgo, Antonella; Rossini, Maurizio; Cimaz, Rolando; Meroni, Pier Luigi

    2018-02-06

    To define the correlation between joint ultrasonography and clinical examination in patients with juvenile idiopathic arthritis (JIA) and to assess whether synovitis detected by ultrasonography in clinically inactive patients predicts arthritis flares. 88 consecutive patients with JIA-46 (52%) with persistent oligoarthritis, 15 (17%) with extended oligoarthritis, 15 (17%) with rheumatoid factor-negative polyarthritis and 12 (14%) with other forms of JIA, all clinically inactive for a minimum of 3 months-underwent ultrasound (US) assessment of 44 joints. Joints were scanned at study entry for synovial hyperplasia, joint effusion and power Doppler (PD) signal. Patients were followed clinically for 4 years. US was abnormal in 20/88 (22.7%) patients and in 38/3872 (0.98%) joints. Extended oligoarthritis and rheumatoid factor-negative polyarthritis were more frequent in US-positive than in US-negative patients (35.0% vs 11.8% and 30.0% vs 13.2%, respectively; P=0.005). During 4 years of follow-up, 41/88 (46.6%) patients displayed a flare; 26/68 (38.2%) were US-negative and 15/20 (75%) were US-positive at baseline. Abnormality on US examination, after correction for therapy modification, significantly increased the risk of flare (OR=3.8, 95% CI 1.2 to 11.5). The combination of grey scale and PD abnormalities displayed a much higher predictive value of relapse (65%, 13/20) than grey scale alone (33%, 6/18). US abnormalities are a strong predictor of relapse at individual patient level. Irrespective of treatment, the risk of flare in US-positive versus US-negative patients was almost four times higher. In case of US abnormalities, patients should be carefully followed regardless of both the International League of Associations for Rheumatology and Wallace categories. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  14. Evaluation of a Standardized Program for Training Practicing Anesthesiologists in Ultrasound-Guided Regional Anesthesia Skills.

    Science.gov (United States)

    Mariano, Edward R; Harrison, T Kyle; Kim, T Edward; Kan, Jack; Shum, Cynthia; Gaba, David M; Ganaway, Toni; Kou, Alex; Udani, Ankeet D; Howard, Steven K

    2015-10-01

    Practicing anesthesiologists have generally not received formal training in ultrasound-guided perineural catheter insertion. We designed this study to determine the efficacy of a standardized teaching program in this population. Anesthesiologists in practice for 10 years or more were recruited and enrolled to participate in a 1-day program: lectures and live-model ultrasound scanning (morning) and faculty-led iterative practice and mannequin-based simulation (afternoon). Participants were assessed and recorded while performing ultrasound-guided perineural catheter insertion at baseline, at midday (interval), and after the program (final). Videos were scored by 2 blinded reviewers using a composite tool and global rating scale. Participants were surveyed every 3 months for 1 year to report the number of procedures, efficacy of teaching methods, and implementation obstacles. Thirty-two participants were enrolled and completed the program; 31 of 32 (97%) completed the 1-year follow-up. Final scores [median (10th-90th percentiles)] were 21.5 (14.5-28.0) of 30 points compared to 14.0 (9.0-20.0) at interval (P < .001 versus final) and 12.0 (8.5-17.5) at baseline (P < .001 versus final), with no difference between interval and baseline. The global rating scale showed an identical pattern. Twelve of 26 participants without previous experience performed at least 1 perineural catheter insertion after training (P < .001). However, there were no differences in the monthly average number of procedures or complications after the course when compared to baseline. Practicing anesthesiologists without previous training in ultrasound-guided regional anesthesia can acquire perineural catheter insertion skills after a 1-day standardized course, but changing clinical practice remains a challenge. © 2015 by the American Institute of Ultrasound in Medicine.

  15. Ultrasound pregnancy

    Science.gov (United States)

    Pregnancy sonogram; Obstetric ultrasonography; Obstetric sonogram; Ultrasound - pregnancy; IUGR - ultrasound; Intrauterine growth - ultrasound; Polyhydramnios - ultrasound; Oligohydramnios - ultrasound; ...

  16. The value of radiological and ultrasound examination in the prenatal diagnosis of the siren syndrome

    International Nuclear Information System (INIS)

    Fiegler, W.; Hunsdiek, F.W.

    1980-01-01

    A sirenomelia is described. In addition to the characteristic single lower extremity, there are also, as in all cases of sympodia, severe malformations in the urogenital system, intestine, pelvis and vertebral column. The various theories of genesis are discussed. Ultrasound can be used as a screening procedure in early detection of deformities. So it is possible to avoid an emergency sectio in cases, where a non-viable child is endangered by intrauterine asphyxia. (orig.) [de

  17. Value of radiological and ultrasound examination in the prenatal diagnosis of the siren syndrome

    Energy Technology Data Exchange (ETDEWEB)

    Fiegler, W; Hunsdiek, F W

    1980-11-01

    A sirenomelia is described. In addition to the characteristic single lower extremity, there are also, as in all cases of sympodia, severe malformations in the urogenital system, intestine, pelvis and vertebral column. The various theories of genesis are discussed. Ultrasound can be used as a screening procedure in early detection of deformities. So it is possible to avoid an emergency section in cases, where a non-viable child is endangered by intrauterine asphyxia.

  18. Value of radiological and ultrasound examination in the prenatal diagnosis of the siren syndrome

    Energy Technology Data Exchange (ETDEWEB)

    Fiegler, W; Hunsdiek, F W

    1980-11-01

    A sirenomelia is described. In addition to the characteristic single lower extremity, there are also, as in all cases of sympodia, severe malformations in the urogenital system, intestine, pelvis and vertebral column. The various theories of genesis are discussed. Ultrasound can be used as a screening procedure in early detection of deformities. So it is possible to avoid an emergency sectio in cases, where a non-viable child is endangered by intrauterine asphyxia.

  19. Parental expectations, experiences and reactions, sense of coherence and grade of anxiety related to routine ultrasound examination with normal findings during pregnancy.

    Science.gov (United States)

    Ekelin, M; Crang Svalenius, E; Larsson, A-K; Nyberg, P; Marsál, K; Dykes, A-K

    2009-10-01

    To investigate parents' expectations, experiences and reactions, sense of coherence and anxiety before and after a second-trimester routine ultrasound examination, with normal findings. Before and after ultrasound questionnaires including the scales parents' expectations, experiences and reactions to routine ultrasound examination (PEER-U state of mind index), sense of coherence (SOC) and state and trait anxiety inventory (STAI), were sent to a 1-year cohort of women and their partners. Replies received were 2183. Both parents had significantly less worried state of mind (PEER-U) after the examination than before. Women had a lower grade of state anxiety after than before, but for men there was no significant change. Before the ultrasound, women had a higher degree of worried state of mind, as well as a higher grade of state and trait anxiety and a lower sense of coherence, than men. The women showed a greater reduction in worried state of mind than the men after the ultrasound examination. There were no significant differences in sense of coherence before and after ultrasound. Women and men are affected in their psychological well-being in relation to a routine ultrasound examination, but their sense of coherence remains stable.

  20. Examining the Perceptions of Brand Images Regarding Competing MBA Programs

    Science.gov (United States)

    Hinds, Timothee; Falgoust, Dexter; Thomas, Kerry, Jr.; Budden, Michael C.

    2010-01-01

    In today's economic environment, it is crucial to create a strong, consistent brand image within a graduate business program. This study examines the perceptions that students at Southeastern Louisiana University hold about its MBA program and the MBA programs of its main competitors. A focus group was conducted to identify competitors and factors…

  1. Examining the Role of Multicultural Competence in Leadership Program Design

    Science.gov (United States)

    Wilson, Amy B.

    2015-01-01

    Research examining the multicultural competence of leadership educators across a variety of institutions demonstrated variance based on leadership program structure, program elements, and the ways in which diversity was addressed in the program. The Multicultural Competence in Student Affairs-Preliminary 2 (MCSA-P2) scale was used to measure…

  2. Accuracy of Medical Students in Detecting Pleural Effusion Using Lung Ultrasound as an Adjunct to the Physical Examination.

    Science.gov (United States)

    Steinmetz, Peter; Oleskevich, Sharon; Dyachenko, Alina; McCusker, Jane; Lewis, John

    2018-03-25

    This study compared the accuracy of medical students in identifying pleural effusion in hospitalized patients using the physical examination versus lung ultrasound (US). Fourth-year medical students (n = 14) received 20 hours of general practical US training (including 2 hours of specialized lung US training) plus theoretical and video documentation. The students used the physical examination alone versus the physical examination plus lung US to document the presence or absence of pleural effusion in the right and left hemithoraces of hospitalized patients (n = 11 patients; 22 hemithoraces examined 544 times in total). The reference standard for identification of pleural effusion was a lung US examination by 2 expert point-of-care sonographers. The odds of correctly identifying the presence versus absence of pleural effusion was 5 times greater with lung US as an adjunct to the physical examination compared to the physical examination alone (odds ratio [OR], 5.1 from multivariate logistic regression; 95% confidence interval, 3.3-8.0). The addition of lung US to the physical examination resulted in an increase in sensitivity from 48% to 90%, in specificity from 73% to 86%, and in accuracy from 60% to 88%. The benefits of using US were greater when pleural effusion was present versus absent (OR, 10.8 versus 2.4) and when examining older versus younger patients (OR, 10.2 versus 2.8). These results demonstrate that medical students' ability to detect the presence or absence of pleural effusion is superior when using lung US as an adjunct to the physical examination than when using the physical examination alone. © 2018 by the American Institute of Ultrasound in Medicine.

  3. Automated assessment of joint synovitis activity from medical ultrasound and power doppler examinations using image processing and machine learning methods

    Directory of Open Access Journals (Sweden)

    Rafal Cupek

    2016-11-01

    Full Text Available Objectives : Rheumatoid arthritis is the most common rheumatic disease with arthritis, and causes substantial functional disability in approximately 50% patients after 10 years. Accurate measurement of the disease activity is crucial to provide an adequate treatment and care to the patients. The aim of this study is focused on a computer aided diagnostic system that supports an assessment of synovitis severity. Material and methods : This paper focus on a computer aided diagnostic system that was developed within joint Polish–Norwegian research project related to the automated assessment of the severity of synovitis. Semiquantitative ultrasound with power Doppler is a reliable and widely used method of assessing synovitis. Synovitis is estimated by ultrasound examiner using the scoring system graded from 0 to 3. Activity score is estimated on the basis of the examiner’s experience or standardized ultrasound atlases. The method needs trained medical personnel and the result can be affected by a human error. Results : The porotype of a computer-aided diagnostic system and algorithms essential for an analysis of ultrasonic images of finger joints are main scientific output of the MEDUSA project. Medusa Evaluation System prototype uses bone, skin, joint and synovitis area detectors for mutual structural model based evaluation of synovitis. Finally, several algorithms that support the semi-automatic or automatic detection of the bone region were prepared as well as a system that uses the statistical data processing approach in order to automatically localize the regions of interest. Conclusions : Semiquantitative ultrasound with power Doppler is a reliable and widely used method of assessing synovitis. Activity score is estimated on the basis of the examiner’s experience and the result can be affected by a human error. In this paper we presented the MEDUSA project which is focused on a computer aided diagnostic system that supports an

  4. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... of page How is the procedure performed? For most ultrasound exams, you will be positioned lying face- ... Ultrasound examinations are painless and easily tolerated by most patients. Ultrasound exams in which the transducer is ...

  5. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... D images. A Doppler ultrasound study may be part of an ultrasound examination. Doppler ultrasound , also called ... terms of the distance traveled per unit of time, rather than as a color picture. It can ...

  6. Dynamic programming in parallel boundary detection with application to ultrasound intima-media segmentation.

    Science.gov (United States)

    Zhou, Yuan; Cheng, Xinyao; Xu, Xiangyang; Song, Enmin

    2013-12-01

    Segmentation of carotid artery intima-media in longitudinal ultrasound images for measuring its thickness to predict cardiovascular diseases can be simplified as detecting two nearly parallel boundaries within a certain distance range, when plaque with irregular shapes is not considered. In this paper, we improve the implementation of two dynamic programming (DP) based approaches to parallel boundary detection, dual dynamic programming (DDP) and piecewise linear dual dynamic programming (PL-DDP). Then, a novel DP based approach, dual line detection (DLD), which translates the original 2-D curve position to a 4-D parameter space representing two line segments in a local image segment, is proposed to solve the problem while maintaining efficiency and rotation invariance. To apply the DLD to ultrasound intima-media segmentation, it is imbedded in a framework that employs an edge map obtained from multiplication of the responses of two edge detectors with different scales and a coupled snake model that simultaneously deforms the two contours for maintaining parallelism. The experimental results on synthetic images and carotid arteries of clinical ultrasound images indicate improved performance of the proposed DLD compared to DDP and PL-DDP, with respect to accuracy and efficiency. Copyright © 2013 Elsevier B.V. All rights reserved.

  7. Estimation of prenatal aorta intima-media thickness from ultrasound examination

    International Nuclear Information System (INIS)

    Veronese, E; Tarroni, G; Grisan, E; Visentin, S; Cosmi, E; Linguraru, M G

    2014-01-01

    Prenatal events such as intrauterine growth restriction and increased cardiovascular risk in later life have been shown to be associated with an increased intima-media thickness (aIMT) of the abdominal aorta in the fetus. In order to assess and manage atherosclerosis and cardiovascular disease risk in adults and children, in recent years the measurement of abdominal and carotid artery thickness has gained a growing appeal. Nevertheless, no computer aided method has been proposed for the analysis of prenatal vessels from ultrasound data, yet. To date, these measurements are being performed manually on ultrasound fetal images by skilled practitioners. The aim of the presented study is to introduce an automatic algorithm that identifies abdominal aorta and estimates its diameter and aIMT from routine third trimester ultrasonographic fetal data. The algorithm locates the aorta, then segments it and, by modeling the arterial wall longitudinal sections by means of a gaussian mixture, derives a set of measures of the aorta diameter (aDiam) and of the intima-media thickness (aIMT). After estimating the cardiac cycle, the mean diameter and the aIMT at the end-diastole phase are computed. Considering the aIMT value for each subject, the correlation between automatic and manual end-diastolic aIMT measurements is 0.91 in a range of values 0.44-1.10 mm, corresponding to both normal and pathological conditions. The automatic system yields a mean relative error of 19%, that is similar to the intra-observer variability (14%) and much lower that the inter-observer variability (42%). The correlation between manual and automatic measurements and the small error confirm the ability of the proposed system to reliably estimate aIMT values in prenatal ultrasound sequences, reducing measurement variability and suggesting that it can be used for an automatic assessment of aIMT. (paper)

  8. Thoracodorsal artery examination with doppler ultrasound in healthy volunteers in a level three hospital

    International Nuclear Information System (INIS)

    Vasquez Rangel, Wolfgang Ignacio; Daza, Gabriel Fernando; Escobar Rojas, William

    2011-01-01

    Introduction: The thoracodorsal artery is a branch of the subscapular artery, which in turn is a branch of the axillary artery. The importance of this artery is that it supplies the latissimus dorsi muscle, used as a muscle-skin flap for breast reconstruction after mastectomy, mainly in patients with poor local tissues, in particular after receiving radiotherapy. Objective: to describe the physical characteristics of the thoracodorsal artery using Doppler ultrasound evaluation in healthy volunteers at Hospital Universitario del Valle. Materials and methods: We conducted a descriptive pilot study, because, after reviewing the medical literature, we did not find any reports assessing the thoracodorsal artery with the use of Doppler ultrasound. Results: we evaluated 51 patients, 50.9% female. The average age of the patients was 28.78 years. the axillary, subscapular and thoracodorsal arteries were identified in all patients. The characteristics of the thoracodorsal artery were as follows: Diameter 1.88 mm, peak systolic velocity 28.45 cm/s, peak diastolic velocity 2.03 cm/s, resistance index 0.94, pulsatility index 4.02. Although the study did not include anthropometric measurements, we found that the artery was more conspicuous in patients with developed muscle mass and in patients with low adiposity. Conclusions: The thoracodorsal artery was identified in all patients, and ultrasound localization is a procedure that is easy to perform and provides vital information about the presence of the vascular pedicle required to perform a latissimus dorsi muscle-skin flap. Additional studies in post mastectomy patients are required in order to assess postoperative changes associated with the presence and physical characteristics of the thoracodorsal artery.

  9. Standardization of the first-trimester fetal cardiac examination using spatiotemporal image correlation with tomographic ultrasound and color Doppler imaging.

    Science.gov (United States)

    Turan, S; Turan, O M; Ty-Torredes, K; Harman, C R; Baschat, A A

    2009-06-01

    The challenges of the first-trimester examination of the fetal heart may in part be overcome by technical advances in three-dimensional (3D) ultrasound techniques. Our aim was to standardize the first-trimester 3D imaging approach to the cardiac examination to provide the most consistent and accurate display of anatomy. Low-risk women with normal findings on first-trimester screening at 11 to 13 + 6 weeks had cardiac ultrasound using the following sequence: (1) identification of the four-chamber view; (2) four-dimensional (4D) volume acquisition with spatiotemporal image correlation (STIC) and color Doppler imaging (angle = 20 degrees, sweep 10 s); (3) offline, tomographic ultrasound imaging (TUI) analysis with standardized starting plane (four-chamber view), slice number and thickness; (4) assessment of fetal cardiac anatomy (four-chamber view, cardiac axis, size and symmetry, atrioventricular valves, great arteries and descending aorta) with and without color Doppler. 107 consecutive women (age, 16-42 years, body mass index 17.2-50.2 kg/m(2)) were studied. A minimum of three 3D volumes were obtained for each patient, transabdominally in 91.6%. Fetal motion artifact required acquisition of more than three volumes in 20%. The median time for TUI offline analysis was 100 (range, 60-240) s. Individual anatomic landmarks were identified in 89.7-99.1%. Visualization of all structures in one panel was observed in 91 patients (85%). Starting from a simple two-dimensional cardiac landmark-the four-chamber view-the standardized STIC-TUI technique enables detailed segmental cardiac evaluation of the normal fetal heart in the first trimester. (c) 2009 ISUOG.

  10. Frequency of recommendations for additional imaging in diagnostic ultrasound examinations: Evaluation of radiologist, technologist, and other examination-related factors.

    Science.gov (United States)

    Margolis, Nathaniel E; Rosenkrantz, Andrew B; Babb, James S; Macari, Michael

    2015-10-01

    Our aim in this study was to evaluate the effect of the radiologist, technologist, and other examination-related factors on the frequency of recommendations for additional imaging (RAI) during sonographic (US) interpretation. We retrospectively reviewed 719 US reports from a single academic medical center for the presence of RAI. All studies had been interpreted by one of three abdominal radiologists. Examinations were performed at an outpatient radiology facility with no onsite radiologist (n = 299) or at an inpatient emergency department or hospital-based outpatient setting that had an onsite radiologist (n = 420). Possible associations between the frequency of RAI and the presence of an onsite radiologist, location of the examination, body part or region imaged, patient age, technologist performing the exam, and radiologist reading the exam were evaluated. There were significant differences between each pair of radiologists in terms of overall frequency of RAI (p technologists (13.6%-40.0%, p = 0.03). However, other factors such as patient age, patient sex, US unit, patient location, and radiologist location were not associated with the frequency of RAI (p = 0.15-0.93). The individual radiologist and technologist influenced the frequency of RAI for US examinations, whereas other examination-related factors did not. The observed substantial variability in RAI between radiologists and technologists warrants further study, with consideration of strategies to optimize RAI within US reports. © 2015 Wiley Periodicals, Inc.

  11. 75 FR 34941 - Review of the Commission's Program Access Rules and Examination of Programming Tying Arrangements

    Science.gov (United States)

    2010-06-21

    ... Commission's Program Access Rules and Examination of Programming Tying Arrangements AGENCY: Federal... Program Access Rules and Examination of Programming Tying Arrangements, MB Docket No. 07-198, FCC 10-17... information collection is contained in Sections 4(i), 303(r), and 628 of the Communications Act of 1934, as...

  12. Examination of a Museum Program for Children with Autism

    Science.gov (United States)

    Mulligan, Shelley; Rais, Paula; Steele-Driscoll, Jacqueline; Townsend, Samantha

    2013-01-01

    This study examined the effectiveness of a children's museum program designed to support young children with autism spectrum disorders (ASD) and their families. The program offers specialized materials, financial incentives, an exclusive time, and trained volunteers to increase the comfort level, enjoyment, and learning opportunities of attendees.…

  13. An Examination of a Gender-Separate Advisory Program

    Science.gov (United States)

    Weilbacher, Gary; Lanier, Jill

    2012-01-01

    In this qualitative study, the authors examine the advisory program of a Horizon Schools to Watch middle grades school. Horizon Schools to Watch is the Illinois affiliate of the National Forum to Accelerate Middle School Reform national Schools to Watch (STW) program, meaning schools with the STW designation have made significant inroads in…

  14. AP: A Critical Examination of the Advanced Placement Program

    Science.gov (United States)

    Sadler, Philip M.; Sonnert, Gerhard; Tai, Robert; Klopfenstein, Kirstin

    2016-01-01

    The Advanced Placement (AP) program was created to enhance the experience of gifted students as they transition from high school to college. "AP: A Critical Examination of the Advanced Placement Program," edited by Philip M. Sadler, Gerhard Sonnert, Robert Tai, and Kirstin Klopfenstein (2010, Harvard Education Press), questions the…

  15. TMI-2 information and examination program 1981 annual report

    International Nuclear Information System (INIS)

    1982-04-01

    The Department of Energy's Technical Information and Examination Program at Three Mile Island Unit 2 continued the research and development work begun on the Island in 1979. The work concentrated in seven major areas: instrumentation and electrical components; radiation and environment; off-site core examination; radioactive waste technology development; configuration and document control; waste immobilization; and reactor evaluation. Research and development work associated with the program aims toward communicating applicable information to the nuclear community. The program seeks to assist in resolving specific problems at TMI-2 and to stimulate interest in specific work activities, thus ensuring that the entire nuclear industry avails itself of the maximum amount of information possible

  16. Impact of a standardized training program on midwives’ ability to assess fetal heart anatomy by ultrasound

    International Nuclear Information System (INIS)

    Hildebrand, Eric; Abrandt Dahlgren, Madeleine; Sved, Catarina; Gottvall, Tomas; Blomberg, Marie; Janerot-Sjoberg, Birgitta

    2014-01-01

    Studies of prenatal detection of congenital heart disease (CHD) in the UK, Italy, and Norway indicate that it should be possible to improve the prenatal detection rate of CHD in Sweden. These studies have shown that training programs, visualization of the outflow tracts and color-Doppler all can help to speed up and improve the detection rate and accuracy. We aimed to introduce a more accurate standardized fetal cardiac ultrasound screening protocol in Sweden. A novel pedagogical model for training midwives in standardized cardiac imaging was developed, a model using a think-aloud analysis during a pre- and post-course test and a subsequent group reflection. The self-estimated difficulties and knowledge gaps of two experienced and two beginner midwives were identified. A two-day course with mixed lectures, demonstrations and hands-on sessions was followed by a feedback session three months later consisting of an interview and check-up. The long-term effects were tested two years later. At the post-course test the self-assessed uncertainty was lower than at the pre-course test. The qualitative evaluation showed that the color Doppler images were difficult to interpret, but the training seems to have improved their ability to use the new technique. The ability to perform the method remained at the new level at follow-up both three months and two years later. Our results indicate that by implementing new imaging modalities and providing hands-on training, uncertainty can be reduced and examination time decreased, but they also show that continuous on-site training with clinical and technical back-up is important

  17. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... be asked to drink water prior to the examination to fill your bladder. Leave jewelry at home ... those sound waves to create an image. Ultrasound examinations do not use ionizing radiation (as used in ...

  18. Therapeutic Ultrasound Examination of Follicular Reserve, and Ovarian Tissue Angiogenesis in Mice, 14 Days after Heterotopic Transplantation

    Directory of Open Access Journals (Sweden)

    N Abtahi

    2014-06-01

    Results: The study results showed that the CD31 angiogenic factor was expressed more in the irradiated animals than in control group animals and ultrasound-therapy resulted in better follicular preservation. Conclusion: The ultrasound therapy can improve preservation of ovarian follicle .This is probably due to acceleration of angiogenesis and increase in production of growth factors by low intensity pulse ultrasound.

  19. Preoperative estimation of the pathological breast tumour size by physical examination, mammography and ultrasound: a prospective study on 105 invasive tumours

    International Nuclear Information System (INIS)

    Bosch, Anne M.; Kessels, Alfons G.H.; Beets, Geerard L.; Rupa, Jan D.; Koster, Dick; Engelshoven, Jos M.A. van; Meyenfeldt, Maarten F. von

    2003-01-01

    Objective: The clinical breast tumour size can be assessed preoperatively by physical examination, mammography and ultrasound. At present it is not clear which modality correlates best with the histological invasive breast tumour size. This prospective study aims to determine the most accurate clinical method (physical examination, mammography or ultrasound) to predict the histological invasive tumour size preoperatively. Methods and patients: Between October 1999 and August 2000, 96 women with 105 invasive malignant breast tumours were included in this study. All patients underwent excision and the tumour size was measured on histology. Tumour size was measured by all three modalities in 73 cases. Results were evaluated by calculating correlation coefficients. The examination modalities presenting the best estimation of the pathological tumour size were used in a stepwise linear regression analysis to construct a formula predicting the pathological tumour size from the result of the various diagnostic modalities. Results: The correlation coefficient between ultrasound and pathological size (r=0.68) was significantly better than the correlations between physical examination and pathological size (r=0.42) and mammographic and pathological size (r=0.44). Physical examination overestimates and ultrasound underestimates breast tumour classification. The most accurate prediction formula was: Pathological tumour size (mm) equals sonographic tumour size (mm)+3 mm. Conclusion: When comparing physical examination, mammography and ultrasound for the prediction of the pathological size of a malignant breast tumour, ultrasound is the best predictor. The ensuing regression formula determines pathological size as tumour size by ultrasound+3 mm. However, with the wide 95% confidence interval of ±11 mm, it remains difficult to predict the exact pathological size for an individual invasive breast tumour. A small deviation in millimetres of the tumour size could lead to a change in

  20. A mixed-methods evaluation of a multidisciplinary point of care ultrasound program.

    Science.gov (United States)

    Smith, Andrew; Parsons, Michael; Renouf, Tia; Boyd, Sarah; Rogers, Peter

    2018-04-24

    Point of Care Ultrasound (PoCUS) is well established within emergency medicine, however, the availability of formal training for other clinical disciplines is limited. Memorial University has established a cost-efficient, multidisciplinary PoCUS training program focusing on training residents' discipline-specific ultrasound skills. This study evaluates the skills, knowledge, and attitudes of residents who participated in the program. Analysis was conducted using a mixed-methods, sequential exploratory approach. Initially, a focus group of seven first year residents was conducted to generate themes that were used to guide development of a survey administered to residents over a two-year period. Thirty residents responded to the survey (response rate 63.8%) with 53.3% meeting the training requirements for focused assessment using sonography in trauma, 43.3% for pleural effusion, 40.0% for aortic aneurysms, and 40.0% for cardiac scans. Early pregnancy assessment was the skill of least interest with 46.6% not interested. Over half the residents (53.6%) agreed or strongly agreed that a multidisciplinary program met their needs while 21.4% disagreed. The focus group found the multidisciplinary approach adequate. A single PoCUS curriculum has been shown to meet the needs and expectations of a majority of residents from multiple disciplines. It can enhance collaboration and bridge gaps between increasingly compartmentalized practices of medicine.

  1. Acquired premature ejaculation and male accessory gland infection: relevance of ultrasound examination

    Directory of Open Access Journals (Sweden)

    Sandro La Vignera

    2016-01-01

    Full Text Available We have previously demonstrated a high frequency of premature ejaculation (PE among patients with male accessory gland infection (MAGI. The aim of this study was to evaluate the ultrasound (US features of patients with MAGI and acquired premature ejaculation (APE associated (MAGI-APEpos. US evaluation of 50 MAGI-APEpos patients compared to 50 patients with MAGI without PE (MAGI-PEneg which represent the control group. The diagnosis of APE was made through the evaluation of Intravaginal ejaculation latency time (IELT and confirmed with the questionnaire PEDT (Premature Ejaculation Diagnostic Tool. The main outcome measure was represented by the frequency of US criteria suggestive of P (prostatitis, V (vesiculitis, and E (epididymitis in MAGI-APEpos and MAGI-PEneg patients. MAGI-APEpos patients showed a total number of US criteria significantly higher compared to MAGI-PEneg patients. MAGI-APEpos showed a higher frequency of US criteria of V and E (complicated forms of MAGI. Finally, in MAGI-APEpos group, it was found a positive relationship between the anteroposterior diameter (APD of the caudal tract of the epididymis and the APD of the seminal vesicles, as well as between both diameters and the PEDT score. MAGI-APEpos patients have a peculiar US characterization compared to MAGI-PEneg patients. According to these results, US evaluation of the epididymal and of the prostato vesicular tract should be considered in the practical clinical approach of patients with MAGI and APE. In particular, it could be a support for a possible pathophysiological interpretation of this clinical problem in these patients.

  2. Diagnosis of Groin Pain Associated With Sports Hernia Using Dynamic Ultrasound and Physical Examination: A Case Report.

    Science.gov (United States)

    Yang, Dong Chan; Nam, Ki Yeun; Kwon, Bum Sun; Park, Jin Woo; Ryu, Ki Hyung; Lee, Ho Jun; Sim, Gyu Jeong

    2015-12-01

    Groin pain in athletes is a complex diagnostic and therapeutic challenge. Sports hernia is one of the common causes of groin pain. We report a case of sports hernia, initially presented as groin pain and aggravated by sports activity. A 19-year-old soccer player visited the outpatient department of general surgery and was referred to the rehabilitation center due to no abnormalities detected in the abdomen and pelvis by computed tomography. An incipient direct bulge of the posterior inguinal wall was detected with dynamic ultrasound when abdominal tension was induced by raising both legs during a full inhalation. Surgery was performed and preoperatively both groins showed the presence of inguinal hernia. Diagnosing sports hernia is very challenging. Through careful history documentation and physical examination followed by dynamic ultrasonography, we identified his posterior inguinal wall deficiency for early management.

  3. The use of a pocket-sized ultrasound device improves physical examination: results of an in- and outpatient cohort study.

    Directory of Open Access Journals (Sweden)

    Agostino Colli

    Full Text Available The performance of pocket mobile ultrasound devices (PUDs is comparable with that of standard ultrasonography, whereas the accuracy of a physical examination is often poor requiring further tests to assess diagnostic hypotheses. Adding the use of PUD to physical examination could lead to an incremental benefit.We assessed whether the use of PUD in the context of physical examination can reduce the prescription of additional tests when used by physicians in different clinical settings.We conducted a cohort impact study in four hospital medical wards, one gastroenterological outpatient clinic, and 90 general practices in the same geographical area. The study involved 135 physicians who used PUD, after a short predefined training course, to examine 1962 consecutive patients with one of 10 diagnostic hypotheses: ascites, pleural effusion, pericardial effusion, urinary retention, urinary stones, gallstones, biliary-duct dilation, splenomegaly, abdominal mass, abdominal aortic aneurysm. According to the physicians' judgment, PUD examination could rule out or in the diagnostic hypothesis or require further testing; the concordance with the final diagnosis was assessed. The main outcome was the proportion of cases in which additional tests were required after PUD. The PUD diagnostic accuracy was assessed in patients submitted to further testing.The 1962 patients included 37% in-patients, 26% gastroenterology outpatients, 37% from general practices. Further testing after PUD examination was deemed unnecessary in 63%. Only 5% of patients with negative PUD not referred for further testing were classified false negatives with respect to the final diagnosis. In patients undergoing further tests, the sensitivity was 91%, and the specificity 83%.After a simple and short training course, a PUD examination can be used in addition to a physical examination to improve the answer to ten common clinical questions concerning in- and outpatients, and can reduce the

  4. Neurolinguistic Programming Examined: Imagery, Sensory Mode, and Communication.

    Science.gov (United States)

    Fromme, Donald K.; Daniell, Jennifer

    1984-01-01

    Tested Neurolinguistic Programming (NLP) assumptions by examining intercorrelations among response times of students (N=64) for extracting visual, auditory, and kinesthetic information from alphabetic images. Large positive intercorrelations were obtained, the only outcome not compatible with NLP. Good visualizers were significantly better in…

  5. Poster - 09: A MATLAB-based Program for Automated Quality Assurance of a Prostate Brachytherapy Ultrasound System

    Energy Technology Data Exchange (ETDEWEB)

    Poon, Justin; Sabondjian, Eric; Sankreacha, Raxa [University of British Columbia, Dept. of Physics and Astronomy, Vancouver, BC (Canada); Trillium Health Partners – Credit Valley Hospital, Peel Regional Cancer Centre, Mississauga, ON, Trillium Health Partners – Credit Valley Hospital, Peel Regional Cancer Centre, Mississauga, ON, Trillium Health Partners – Credit Valley Hospital, Peel Regional Cancer Centre, Mississauga, ON (Canada); University of Toronto, Dept. of Radiation Oncology, Toronto, ON (Canada)

    2016-08-15

    Purpose: A robust Quality Assurance (QA) program is essential for prostate brachytherapy ultrasound systems due to the importance of imaging accuracy during treatment and planning. Task Group 128 of the American Association of Physicists in Medicine has recommended a set of QA tests covering grayscale visibility, depth of penetration, axial and lateral resolution, distance measurement, area measurement, volume measurement, and template/electronic grid alignment. Making manual measurements on the ultrasound system can be slow and inaccurate, so a MATLAB program was developed for automation of the described tests. Methods: Test images were acquired using a BK Medical Flex Focus 400 ultrasound scanner and 8848 transducer with the CIRS Brachytherapy QA Phantom – Model 045A. For each test, the program automatically segments the inputted image(s), makes the appropriate measurements, and indicates if the test passed or failed. The program was tested by analyzing two sets of images, where the measurements from the first set were used as baseline values. Results: The program successfully analyzed the images for each test and determined if any action limits were exceeded. All tests passed – the measurements made by the program were consistent and met the requirements outlined by Task Group 128. Conclusions: The MATLAB program we have developed can be used for automated QA of an ultrasound system for prostate brachytherapy. The GUI provides a user-friendly way to analyze images without the need for any manual measurement, potentially removing intra- and inter-user variability for more consistent results.

  6. Poster - 09: A MATLAB-based Program for Automated Quality Assurance of a Prostate Brachytherapy Ultrasound System

    International Nuclear Information System (INIS)

    Poon, Justin; Sabondjian, Eric; Sankreacha, Raxa

    2016-01-01

    Purpose: A robust Quality Assurance (QA) program is essential for prostate brachytherapy ultrasound systems due to the importance of imaging accuracy during treatment and planning. Task Group 128 of the American Association of Physicists in Medicine has recommended a set of QA tests covering grayscale visibility, depth of penetration, axial and lateral resolution, distance measurement, area measurement, volume measurement, and template/electronic grid alignment. Making manual measurements on the ultrasound system can be slow and inaccurate, so a MATLAB program was developed for automation of the described tests. Methods: Test images were acquired using a BK Medical Flex Focus 400 ultrasound scanner and 8848 transducer with the CIRS Brachytherapy QA Phantom – Model 045A. For each test, the program automatically segments the inputted image(s), makes the appropriate measurements, and indicates if the test passed or failed. The program was tested by analyzing two sets of images, where the measurements from the first set were used as baseline values. Results: The program successfully analyzed the images for each test and determined if any action limits were exceeded. All tests passed – the measurements made by the program were consistent and met the requirements outlined by Task Group 128. Conclusions: The MATLAB program we have developed can be used for automated QA of an ultrasound system for prostate brachytherapy. The GUI provides a user-friendly way to analyze images without the need for any manual measurement, potentially removing intra- and inter-user variability for more consistent results.

  7. TMI-2 Technical Information and Examination Program. 1982 annual report

    International Nuclear Information System (INIS)

    1983-04-01

    The Department of Energy's Technical Information and Examination Program at Three Mile Island Unit 2 continued the research and development work begun on the island in 1980. The work concentrated in seven major areas: instrumentation and electrical components, radiation and environment, core activities, information and industry coordination, configuration and document control, waste immobilization, and reactor evaluation. The program assists in resolving specific problems at TMI-2 while developing techniques and broadening understanding of accident consequences to improve the overall safety and reliability of nuclear power. The Technical Information and Examination Program aims to communicate applicable information to the nuclear power industry to ensure that the industry can avail itself of the maximum amount of information possible

  8. TMI-2 Technical Information and Examination Program 1983 annual report

    International Nuclear Information System (INIS)

    Scardena, D.E.

    1984-04-01

    The Department of Energy's Technical Information and Examination Program at Three Mile Island Unit 2 continued the research and development work begun on the Island in 1980. The work concentrated in six major areas: waste immobilization, reactor evaluation, data acquisition, information and industry coordination, core activities, and EPICOR II and waste research and disposition. The program assists in resolving specific problems at TMI-2 while developing techniques and broadening understanding of accident consequences to improve the overall safety and reliability of nuclear power. The Technical Information and Examination Program aims to communicate applicable information to the nuclear power industry to ensure that the industry can avail itself to the maximum amount of information possible

  9. Cooperation between National Defense Medical College and Fukushima Medical University in thyroid ultrasound examination after the Fukushima Daiichi nuclear power plant disaster

    International Nuclear Information System (INIS)

    Yamamoto, Yoritsuna; Fujita, Masanori; Tachibana, Shoich; Morita, Koji; Hamano, Kunihisa; Hamada, Koji; Uchida, Kosuke; Tanaka, Yuji

    2013-01-01

    Fukushima Daiichi Nuclear Power Plant was utterly destroyed by The Great East Japan Earthquake which happened on March 11, 2011, and followed by radioactive contamination to the surrounding areas. Based on the known radioactive iodine ("1"3"1I) which led to thyroid cancer in children after the Chernobyl nuclear power plant disaster in 1986, children living in Fukushima should be carefully observed for the development of thyroid cancer. Fukushima Prefecture and Fukushima Medical University started ''Fukushima Health Management Survey'' in May 2011, which includes screening for thyroid cancer by ultrasonography (Thyroid Ultrasound Examination). Thyroid Ultrasound Examination would cover roughly 360,000 residents aged 0 to 18 years of age at the time of the nuclear disaster. The initial screening is to be performed within the first three years after the accident, followed by complete thyroid examinations from 2014 onwards, and the residents will be monitored regularly thereafter. As Thyroid Ultrasound Examination is being mainly performed by medical staff at Fukushima Medical University, there is insufficient manpower to handle the large number of potential examinees. Thus, specialists of thyroid diseases from all over Japan have begun to support this examination. Six endocrinologists including the authors belonging to the National Defense Medical College are cooperating in part of this examination. This paper briefly reports the outline of Thyroid Ultrasound Examination and our cooperation. (author)

  10. Comparison the percentage of detection of periarthritis in patients with rheumatoid arthritis using clinical examination or ultrasound methods

    Directory of Open Access Journals (Sweden)

    Hadi Karimzadeh

    2016-01-01

    Full Text Available Background: This study aimed to compare the percentage of detection of periarthritis in patients with rheumatoid arthritis using clinical examination and ultrasound methods. Materials and Methods: This study is a cross-sectional study which was conducted in Al-Zahra Hospital (Isfahan, Iran during 2014–2015. In our study, ninety patients were selected based on the American College of Rheumatology 2010 criteria. All patients were examined by a rheumatologist to find the existence of effusion, and the data were filled in the checklist. The ultrasonography for detecting effusion in periarticular structures was done by an expert radiologist with two methods, including high-resolution ultrasonography and power Doppler. The percentage of effusion existence found by physical examination was compared by sonography, and the Chi-square and t-tests were used for data analysis. Results: The percentage of effusion found in areas with physical examination by rheumatologist was lower than the frequency distribution of effusions found by sonography (8.3% VS 14.2% (P < 0.001. In sonography, rotator cuff tendonitis is the most common periarthritis. Other findings in sonography were biceps tendinitis (10 cases, wrist tendonitis (13 cases, olecranon bursitis (9 cases, golfers elbow (4 cases, tennis elbow (4 cases, trochanteric bursitis (6 cases, anserine bursitis (6 cases, prepatellar bursitis (11 cases, and ankle tendonitis (7 cases. Tenderness on physical examination was found in 15% of the cases, and the evidence of periarthritis was found in 21/7% through sonography (P < 0.001 and 34% through Doppler sonography (P < 0.001. Conclusion: The percentage of periarthritis detection by ultrasonography and power Doppler sonography was higher than clinical examination. Hence, the ultrasonography is more accurate than physical examination.

  11. Comparison the percentage of detection of periarthritis in patients with rheumatoid arthritis using clinical examination or ultrasound methods.

    Science.gov (United States)

    Karimzadeh, Hadi; Seyedbonakdar, Zahra; Mousavi, Maryam; Karami, Mehdi

    2016-01-01

    This study aimed to compare the percentage of detection of periarthritis in patients with rheumatoid arthritis using clinical examination and ultrasound methods. This study is a cross-sectional study which was conducted in Al-Zahra Hospital (Isfahan, Iran) during 2014-2015. In our study, ninety patients were selected based on the American College of Rheumatology 2010 criteria. All patients were examined by a rheumatologist to find the existence of effusion, and the data were filled in the checklist. The ultrasonography for detecting effusion in periarticular structures was done by an expert radiologist with two methods, including high-resolution ultrasonography and power Doppler. The percentage of effusion existence found by physical examination was compared by sonography, and the Chi-square and t -tests were used for data analysis. The percentage of effusion found in areas with physical examination by rheumatologist was lower than the frequency distribution of effusions found by sonography (8.3% VS 14.2%) ( P tendinitis (10 cases), wrist tendonitis (13 cases), olecranon bursitis (9 cases), golfers elbow (4 cases), tennis elbow (4 cases), trochanteric bursitis (6 cases), anserine bursitis (6 cases), prepatellar bursitis (11 cases), and ankle tendonitis (7 cases). Tenderness on physical examination was found in 15% of the cases, and the evidence of periarthritis was found in 21/7% through sonography ( P < 0.001) and 34% through Doppler sonography ( P < 0.001). The percentage of periarthritis detection by ultrasonography and power Doppler sonography was higher than clinical examination. Hence, the ultrasonography is more accurate than physical examination.

  12. Examination of the program to avoid round-off error

    International Nuclear Information System (INIS)

    Shiota, Y.; Kusunoki, T.; Tabushi, K.; Shimomura, K.; Kitou, S.

    2005-01-01

    The MACRO programs which express a simple shape such as PLANE, SPHERE, CYLINDER and CONE, are used to the formation of the geometry in EGS4. Each MACRO calculates the important value for the main code to recognize the configured geometry. This calculation process may generate the calculation error due to the effect of a round-off error. SPHERE, CYLINDER and CONE MACRO include the function to avoid the effect, but PLANE MACRO dose not include. The effect of the round-off error is small usually in case of PLANE MACRO, however a slant plane may cause the expansion of the effect. Therefore, we have configured the DELPLANE program with the function to avoid the effect of the round-off error. In this study, we examine the DELPLANE program using the simply geometry with slant plane. As a result, the normal PLANE MACRO generates the round-off error, however DELPLANE program dose not generates one. (author)

  13. Prostate Ultrasound

    Medline Plus

    Full Text Available ... is located directly in front of the rectum, so the ultrasound exam is performed transrectally in order ... A follow-up examination may also be necessary so that any change in a known abnormality can ...

  14. Prostate Ultrasound

    Medline Plus

    Full Text Available ... prostate gland and to help diagnose symptoms such as difficulty urinating or an elevated blood test result. ... image. Ultrasound examinations do not use ionizing radiation (as used in x-rays ), thus there is no ...

  15. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... the examination process. To ensure a smooth experience, it often helps to explain the procedure to the ... on the amplitude (loudness), frequency (pitch) and time it takes for the ultrasound signal to return from ...

  16. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... pain ambiguous genitalia and anomalies of pelvic organs early or delayed puberty in girls Pelvic ultrasound is ... sensitive to motion, and an active or crying child can prolong the examination process. To ensure a ...

  17. 75 FR 9691 - Review of the Commission's Program Access Rules and Examination of Programming Tying Arrangements

    Science.gov (United States)

    2010-03-03

    ... involving programming they own, that impede competition in the video distribution market. See H.R. Rep. No... availability of programming and charging discriminatory prices to non- cable technologies.'' H.R. Rep. No. 102... Access Rules and Examination of Programming Tying Arrangements; Final Rule #0;#0;Federal Register / Vol...

  18. Care and economic impact of thyroid ultrasound examination at single visits to endocrinology clinics (the ETIEN 1 study).

    Science.gov (United States)

    Carral, Florentino; Ayala, María del Carmen; Jiménez, Ana Isabel; García, Concepción

    2016-02-01

    Routine thyroid ultrasound examination in a single medical appointment is rarely performed in Spain. The objective of this study was to evaluate the care and economic impact of thyroid US examination in a single endocrine appointment. A prospective, observational, descriptive study was conducted to analyze data from 2274 patients (mean age, 59±16 years; 83% females) performed at least one thyroid US in a single visit to an endocrinology clinic during 2013 and 2014. The number of endocrine acts with thyroid US, single endocrine and US acts without review, and the change in the number of thyroid US requested by endocrinologists to the radiology department and total thyroid US examinations performed at the radiology department during the study period were assessed. In 2013 and 2014, 2558 endocrine acts with thyroid US were performed, of which 42.2% were single endocrine and US appointments without a second endocrine act, with estimated savings of €58,946.40. As compared to 2012, the number of thyroid US requested by endocrinologists to the radiology department decreased by 43.3% and 86.0% in 2013 and 2014 respectively, and total thyroid US performed by the radiology department decreased by 28.1% and 68.3% respectively, with estimated savings of €94,441.36. Thyroid US examination in a single endocrine appointment allows for decreasing the number of both second endocrine acts and thyroid US examinations performed at the radiology department, thus reducing the number of unnecessary clinic visits and promoting considerable economic savings. Copyright © 2015 SEEN. Published by Elsevier España, S.L.U. All rights reserved.

  19. A group of patients with Marfan's syndrome, who have finger and toe contractures, displays tendons' alterations upon an ultrasound examination: are these features common among classical Marfan patients?

    Science.gov (United States)

    Melchiorre, Daniela; Pratelli, Elisa; Torricelli, Elena; Sofi, Francesco; Abbate, Rosanna; Matucci-Cerinic, Marco; Gensini, GianFranco; Pepe, Guglielmina

    2016-08-01

    The involvement of the musculoskeletal system with other mild pleiotropic manifestations represents a clinical criterion, called "systemic features," to d iagnose Marfan's syndrome. We aimed to investigate the features of the hands and feet redressable contractures present in a group of Marfan patients. In 13 patients with previously diagnosed Marfan's syndrome, an accurate clinical examination was performed. In particular the characterization of the musculoskeletal system by visual analogic scale to measure muscle pain (VAS) and muscle strength (MRC system) was carried out; the Beighton scale score was used to evaluate the articular hypermobility. Ultrasound examination (US) was performed to detect deep-superficial flexor tendons and extensor tendons of both hands, and the short and long flexor and extensor tendons of the fingers and toes in static and dynamic positions. The ImageJ program was adopted to measure a profile of tendon echo-intensity. A reduction of the thickness of all tendons was detected by US in our patients; the VAS and Beighton scale scores were in normal ranges. The profile of tendon echo-intensity showed different textural details in all Marfan patients. This study provides evidence for other contractures' localization, and for altered findings of the tendons in patients with Marfan syndrome and finger/toe contractures. These changes may be associated with structural modifications in connective tissue.

  20. A COMPARATIVE STUDY OF CLINICAL EXAMINATION, ULTRASOUND FINDINGS, DIAGNOSTIC HYSTEROSCOPY WITH HISTOPATHOLOGICAL EXAMINATION REPORT OF ENDOMETRIUM IN PATIENTS WITH ABNORMAL UTERINE BLEEDING

    Directory of Open Access Journals (Sweden)

    Sathenahalli Devegowda Prathibha

    2016-08-01

    Full Text Available BACKGROUND AND OBJECTIVES Abnormal Uterine Bleeding (AUB is a very frequent gynaecological complaint and occurs across the entire age spectrum, approximately 75000 hysterectomies are carried out each year with 30% of these for menstrual problems alone. These menstrual aberrations occur more commonly at extremes of reproductive life. The introduction of hysteroscopy has opened a new dimension in evaluation of patient with AUB replacing the blind technique of Dilatation and Curettage. The present study was undertaken to know the accuracy of various tests with Histopathology. MATERIALS AND METHODS The present prospective study was carried out on 100 patients from reproductive, perimenopausal and postmenopausal age group with abnormal uterine bleeding in Dr. B. R. Ambedkar Medical College and Hospital. RESULTS In the present study, in relation to histopathological examination, clinical findings and hysteroscopy had better accuracy (72% as compared to ultrasound findings (41% in diagnosis of abnormal uterine bleeding. CONCLUSION Hysteroscopy guided biopsy and histopathology complements each other in the evaluation of patient with abnormal uterine bleeding for accurate diagnosis and further treatment.

  1. Relationship between internal medicine program board examination pass rates, accreditation standards, and program size.

    Science.gov (United States)

    Falcone, John L; Gonzalo, Jed D

    2014-01-19

    To determine Internal Medicine residency program compliance with the Accreditation Council for Graduate Medical Education 80% pass-rate standard and the correlation between residency program size and performance on the American Board of Internal Medicine Certifying Examination. Using a cross-sectional study design from 2010-2012 American Board of Internal Medicine Certifying Examination data of all Internal Medicine residency pro-grams, comparisons were made between program pass rates to the Accreditation Council for Graduate Medical Education pass-rate standard. To assess the correlation between program size and performance, a Spearman's rho was calculated. To evaluate program size and its relationship to the pass-rate standard, receiver operative characteristic curves were calculated. Of 372 Internal Medicine residency programs, 276 programs (74%) achieved a pass rate of =80%, surpassing the Accreditation Council for Graduate Medical Education minimum standard. A weak correlation was found between residency program size and pass rate for the three-year period (p=0.19, pInternal Medicine residency programs complied with Accreditation Council for Graduate Medical Education pass-rate standards, a quarter of the programs failed to meet this requirement. Program size is positively but weakly associated with American Board of Internal Medicine Certifying Examination performance, suggesting other unidentified variables significantly contribute to program performance.

  2. Cranial Ultrasound/Head Ultrasound

    Science.gov (United States)

    ... used to screen for brain conditions associated with prematurity, such as bleeding or brain tissue damage as ... or crying child will slow the examination process. Large patients are more difficult to image by ultrasound, ...

  3. TMI-2 Technical Information and Examination Program. 1984 annual report

    International Nuclear Information System (INIS)

    Hess, C.J.

    1985-04-01

    In 1984, the US Department of Energy's Technical Information and Examination Program entered its fifth year of research and development work at Three Mile Island Unit 2 (TMI-2) and at the Idaho National Engineering Laboratory and other supporting laboratories. The work concentrated on six major areas: waste immobilization, reactor evaluation, data acquisition, information and industry coordination, core activities, and EPICOR II and waste research and disposition

  4. Color Doppler imaging and measurements of intraovarian and intrauterine vascularization on basal ultrasound examination in spontaneous ovulatory and anovulatory cycles

    Directory of Open Access Journals (Sweden)

    Kutlešić Ranko

    2008-01-01

    Full Text Available Background/Aim. Any organs functioning directly depends on vascularization. It applies also to the uterus and ovary which go through changes of vascularization during a menstruation cycle. The aim of this investigation was to determine differences in intrauterine and ovarian stromal arterioral blood flow on basal ultrasound examination (day 2-4 between spontaneous ovulatory and anovulatory cycles. Methods. This prospective clinical investigation included 205 patients divided into two groups: with ovulatory and with anovulatory cycles. Results. Resistance to ovarian arterioral stromal blood flow was significantly lower in the patients with ovulatory cycles (pulsatile index - PI 0.97 ± 0.4 vs 1.93 ± 1.37; p = 0.001737; and (resistance index - RI 0.55 ± 0.12 vs 0.68 ± 0.14; p = 0.040033. There were no statistically significant differences in arcuate arterioral blood flow in the pateints with ovulatory and anovulatory cycles (PI 1.21 ± 0.34 vs 61 ± 0,61 p = 0.136161 and RI 0.64 ± 0.11 vs 0.74 ± 0.07; p = 0.136649. The patients with ovulatory cycles had lower uterine radial arterioral blood flow than the patients with anovulatory cycles (PI 1.001 ± 0.22 vs 1.61 ± 0.23 p = 0.007501 and RI 0.55 ± 0.08 vs 0.71 ± 0.12; p = 0,0460113. The patients with ovulatory cycles had lower subendometrial arterioral blood flow resistance (PI 0.69 ± 0.19 vs 1.385±0.09; p = 0.00622 and RI 0.44 ± 0.09 vs 0.65 ± 0.02; p = 0.027458. Conclusion. Color Doppler ultrasuond imaging and measurements of intrauterine and ovarian stromal arterioral blood flow on basal ultrasound examination (day 2-4, showed lower resistance to blood flow in ovulatory than in anovulatory cycles.

  5. Children's (Pediatric) Abdominal Ultrasound Imaging

    Medline Plus

    Full Text Available ... child's abdominal ultrasound examination. Doppler ultrasound , also called color Doppler ultrasonography, is a special ultrasound technique that ... and processes the sounds and creates graphs or color pictures that represent the flow of blood through ...

  6. Children's (Pediatric) Abdominal Ultrasound Imaging

    Medline Plus

    Full Text Available ... News Physician Resources Professions Site Index A-Z Children's (Pediatric) Ultrasound - Abdomen Children’s (pediatric) ultrasound imaging of ... 30 minutes. top of page What will my child experience during and after the procedure? Ultrasound examinations ...

  7. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... Ultrasound - Abdomen Obstetric Ultrasound Ultrasound - Prostate Kidney and Bladder Stones Abnormal Vaginal Bleeding Ovarian Cancer Images related to Ultrasound - Pelvis Sponsored by Please ...

  8. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... Children's (Pediatric) Ultrasound - Abdomen Obstetric Ultrasound Ultrasound - Prostate Kidney and Bladder Stones Abnormal Vaginal Bleeding Ovarian Cancer Images related to Ultrasound - Pelvis Sponsored by Please ...

  9. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... specific content. Related Articles and Media Sonohysterography Ultrasound - Abdomen Children's (Pediatric) Ultrasound - Abdomen Obstetric Ultrasound Ultrasound - Prostate Kidney and ...

  10. Focused ultrasound-mediated noninvasive blood-brain barrier modulation: preclinical examination of efficacy and safety in various sonication parameters.

    Science.gov (United States)

    Shin, Jaewoo; Kong, Chanho; Cho, Jae Sung; Lee, Jihyeon; Koh, Chin Su; Yoon, Min-Sik; Na, Young Cheol; Chang, Won Seok; Chang, Jin Woo

    2018-02-01

    OBJECTIVE The application of pharmacological therapeutics in neurological disorders is limited by the ability of these agents to penetrate the blood-brain barrier (BBB). Focused ultrasound (FUS) has recently gained attention for its potential application as a method for locally opening the BBB and thereby facilitating drug delivery into the brain parenchyma. However, this method still requires optimization to maximize its safety and efficacy for clinical use. In the present study, the authors examined several sonication parameters of FUS influencing BBB opening in small animals. METHODS Changes in BBB permeability were observed during transcranial sonication using low-intensity FUS in 20 adult male Sprague-Dawley rats. The authors examined the effects of FUS sonication with different sonication parameters, varying acoustic pressure, center frequency, burst duration, microbubble (MB) type, MB dose, pulse repetition frequency (PRF), and total exposure time. The focal region of BBB opening was identified by Evans blue dye. Additionally, H & E staining was used to identify blood vessel damage. RESULTS Acoustic pressure amplitude and burst duration were closely associated with enhancement of BBB opening efficiency, but these parameters were also highly correlated with tissue damage in the sonicated region. In contrast, MB types, MB dose, total exposure time, and PRF had an influence on BBB opening without conspicuous tissue damage after FUS sonication. CONCLUSIONS The study aimed to identify these influential conditions and provide safety and efficacy values for further studies. Future work based on the current results is anticipated to facilitate the implementation of FUS sonication for drug delivery in various CNS disease states in the near future.

  11. From a formal training program in musculoskeletal ultrasound (MSUS) to a high reproducibility for Doppler ultrasound in rheumatoid arthritis.

    Science.gov (United States)

    Villota, Orlando; Diaz, Mario; Ceron, Carmen; Moller, Ingrid; Naredo, Esperanza; Saaibi, Diego Luis

    2017-07-28

    To assess the intra- and inter-observer reliability of ultrasound (US) in scoring B-mode, Doppler synovitis and combined B-mode and Doppler synovitis scores in different peripheral joints of rheumatoid arthritis (RA) patients. Four rheumatologists with a formal training in musculoskeletal US (MSKUS) particularly focus on definitions and scoring synovitis on B-mode and Doppler mode participated in a patient-based reliability exercise on 16 active RA patients. The four rheumatologists independently and consecutively performed a B-mode and power Doppler (PD) US assessment of 7 joints of each patient in two rounds in a blinded fashion. Each joint was semi quantitatively scored from 0 to 3 for B-mode synovitis (BS), Doppler synovitis (DS), and combined B-mode/Doppler synovitis (CS). Intraobserver reliability was assessed by Cohen's κ. Interobserver reliability was assessed by unweight Light's κ. The mean prevalence of synovitis on B-mode was 83% of joints; scores ranging from grade 1 in 18% of joints, to grade 3 in 33%. In 55% of joints synovial PD signal was detected and the distribution of scores range from 14% of joints for grade 3, to 26% for grade 2. After a total of 448 joints scanned with 896 adquired images our intraobserver and interobserver reliability was good to excellent for most of the joints. Formal, structured and continuous training in musculoskeletal ultrasound would bring a good to excellent reproducibility in rheumatological hands with a high reliability in real time acquisition BS, DS and CS modalities for scoring synovitis in patients with active rheumatoid arthritis. Copyright© Bentham Science Publishers; For any queries, please email at epub@benthamscience.org.

  12. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... procedure? Ultrasound examinations can help to diagnose a variety of conditions and to assess organ damage following ... the Ultrasound-Guided Breast Biopsy page . diagnose a variety of heart conditions, including valve problems and congestive ...

  13. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... image. Ultrasound examinations do not use ionizing radiation (as used in x-rays ), thus there is no ... structure and movement of the body's internal organs, as well as blood flowing through blood vessels. Ultrasound ...

  14. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... ultrasound. top of page How does the procedure work? Ultrasound imaging is based on the same principles ... more extensive exams may take up to an hour. When the examination is complete, you may be ...

  15. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... may produce minimal discomfort. If a Doppler ultrasound study is performed, you may actually hear pulse-like sounds that change in pitch as the blood flow is monitored and measured. Most ultrasound examinations ...

  16. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... Ultrasound is safe, noninvasive, and does not use ionizing radiation. This procedure requires little to no special preparation. ... create an image. Ultrasound examinations do not use ionizing radiation (as used in x-rays ), thus there is ...

  17. The Stored Waste Examination Pilot Plant program at the INEL

    International Nuclear Information System (INIS)

    McKinley, K.B.; Anderson, B.C.; Clements, T.L.; Hinckley, J.P.; Mayberry, J.L.; Smith, T.H.

    1983-01-01

    Since 1970, defense transuranic waste has been placed into 20-year retrievable storage at the Radioactive Waste Management Complex at the Idaho National Engineering Laboratory (INEL). A major objective of the U.S. Department of Energy (DOE) Nuclear Waste Management Program is to remove all retrievably stored transuranic waste from the INEL. The January 1981 DOE Record of Decision on the Waste Isolation Pilot Plant (WIPP) stated, ''The WIPP facility will dispose of defense transuranic waste stored retrievably at the Idaho National Engineering Laboratory.'' After retrieval and before shipment, processing may be necessary to prepare the waste for acceptance, handling, and enhanced long-term isolation in the WIPP. However, some of the waste is certifiable to the WIPP waste acceptance criteria without container opening or waste processing. To minimize costs, the Stored Waste Examination Pilot Plant (SWEPP) is being developed to certify INEL stored transuranic waste without container opening or waste processing. The SWEPP certification concept is based on records assessment, nondestructive examination techniques, assay techniques, health physics examinations, and limited opening of containers at another facility for quality control

  18. Examining the Factors of Licensure Examination for Teachers Performance for Program Strategy Enhancement

    Directory of Open Access Journals (Sweden)

    Januard D. Dagdag

    2017-11-01

    Full Text Available Passing the Licensure Examination for Teachers (LET has been the ultimate focus of tertiary education institutions in the Philippines to meet the present demand of local and global parties and communities. Hence, various strategies are conducted to increase the likelihood that the prospect will happen. With this, the current study determines the predictors of LET performance of the 146 Bachelor of Secondary Education graduates that could serve as basis for enhancing program strategies for a better LET rating. A descriptive correlational method through the analysis of registration data on LET, grade weighted average, college admission test (CAT scores, and course audit scores was conducted. Descriptive statistics and correlational tests were employed in the analysis of these data. Results showed that low LET performance is influenced by low performances in academics and admission test, and limited course audit units taken. Admission test performance, however, does not predict LET performance in Major. On the other hand, course audit performance can only forecast licensure exam scores in Major. Hence, to increase LET performance, the program should consider benchmarking from LET performing institutions, choose the right faculty to teach a course, secure the validity and/or reliability of instructional materials and assessment tools with LET competencies, strictly implement the admission and retention policy, and assess regularly the efficacy of the course audit in all areas

  19. Prostate Ultrasound

    Medline Plus

    Full Text Available ... Physician Resources Professions Site Index A-Z Ultrasound - Prostate Ultrasound of the prostate uses sound waves to ... Ultrasound Imaging? What is Ultrasound Imaging of the Prostate? Ultrasound is safe and painless, and produces pictures ...

  20. Quantitative analysis of ultrasound B-mode images of carotid atherosclerotic plaque: correlation with visual classification and histological examination

    DEFF Research Database (Denmark)

    Wilhjelm, Jens E.; Grønholdt, Marie-Louise; Wiebe, Brit

    1998-01-01

    regions of the plaque in still ultrasound images from three orthogonal scan planes and finally a histological analysis of the surgically removed plaque. The quantitative comparison was made with the linear model and with separation of the available data into training and test sets. The comparison......This paper presents a quantitative comparison of three types of information available for 52 patients scheduled for carotid endarterectomy: subjective classification of the ultrasound images obtained during scanning before operation, first- and second-order statistical features extracted from...

  1. A low-cost ultrasound program leads to increased antenatal clinic visits and attended deliveries at a health care clinic in rural Uganda.

    Directory of Open Access Journals (Sweden)

    Andrew B Ross

    Full Text Available BACKGROUND: In June of 2010, an antenatal ultrasound program to perform basic screening for high-risk pregnancies was introduced at a community health care center in rural Uganda. Whether the addition of ultrasound scanning to antenatal visits at the health center would encourage or discourage potential patients was unknown. Our study sought to evaluate trends in the numbers of antenatal visits and deliveries at the clinic, pre- and post-introduction of antenatal ultrasound to determine what effect the presence of ultrasound at the clinic had on these metrics. METHODS AND FINDINGS: Records at Nawanyago clinic were reviewed to obtain the number of antenatal visits and deliveries for the 42 months preceding the introduction of ultrasound and the 23 months following. The monthly mean deliveries and antenatal visits by category (first visit through fourth return visit were compared pre- and post- ultrasound using a Kruskal-Wallis one-way ANOVA. Following the introduction of ultrasound, significant increases were seen in the number of mean monthly deliveries and antenatal visits. The mean number of monthly deliveries at the clinic increased by 17.0 (13.3-20.6, 95% CI from a pre-ultrasound average of 28.4 to a post-ultrasound monthly average of 45.4. The number of deliveries at a comparison clinic remained flat over this same time period. The monthly mean number of antenatal visits increased by 97.4 (83.3-111.5, 95% CI from a baseline monthly average of 133.5 to a post-ultrasound monthly mean of 231.0, with increases seen in all categories of antenatal visits. CONCLUSIONS: The availability of a low-cost antenatal ultrasound program may assist progress towards Millennium Development Goal 5 by encouraging women in a rural environment to come to a health care facility for skilled antenatal care and delivery assistance instead of utilizing more traditional methods.

  2. Serial measurements of serum human placental lactogen (hPL) and serial ultrasound examinations in the evaluation of fetal growth

    DEFF Research Database (Denmark)

    Sørensen, Steen; von Tabouillot, D; Schioler, V

    2000-01-01

    Serial serum hPL measurements and serial ultrasound fetometry were compared in the evaluation of fetal growth by relating these two parameters to size at birth and to clinical factors known to influence size at birth. The data were from a prospective study of 1000 consecutive pregnant women...... considered to be at risk for fetal growth retardation with retrospective analysis. Serum hPL was measured by radioimmunoassay and fetal weight estimated by ultrasound every 3 weeks during the last trimester. hPL values were expressed as multiples of the median (MoM) and linear regression analysis of the h......PL MoM values was carried out for each pregnancy to find the slope of the line (hPL-slope); at least 3 serum hPL values were required. The estimated fetal weight and weight-for-age at birth was expressed in Z-scores. The individual intrauterine growth velocity was calculated by regression analysis...

  3. Prostate Ultrasound

    Medline Plus

    Full Text Available ... through blood vessels. Ultrasound imaging is a noninvasive medical test that helps physicians diagnose and treat medical conditions. Prostate ultrasound, also called transrectal ultrasound, provides ...

  4. Examining quality improvement programs: the case of Minnesota hospitals.

    Science.gov (United States)

    Olson, John R; Belohlav, James A; Cook, Lori S; Hays, Julie M

    2008-10-01

    To determine if there is a hierarchy of improvement program adoption by hospitals and outline that hierarchy. Primary data were collected in the spring of 2007 via e-survey from 210 individuals representing 109 Minnesota hospitals. Secondary data from 2006 were assembled from the Leapfrog database. As part of a larger survey, respondents were given a list of improvement programs and asked to identify those programs that are used in their hospital. DATA COLLECTION/DATA EXTRACTION: Rasch Model Analysis was used to assess whether a unidimensional construct exists that defines a hospital's ability to implement performance improvement programs. Linear regression analysis was used to assess the relationship of the Rasch ability scores with Leapfrog Safe Practices Scores to validate the research findings. Principal Findings. The results of the study show that hospitals have widely varying abilities in implementing improvement programs. In addition, improvement programs present differing levels of difficulty for hospitals trying to implement them. Our findings also indicate that the ability to adopt improvement programs is important to the overall performance of hospitals. There is a hierarchy of improvement programs in the health care context. A hospital's ability to successfully adopt improvement programs is a function of its existing capabilities. As a hospital's capability increases, the ability to successfully implement higher level programs also increases.

  5. Prostate Ultrasound

    Medline Plus

    Full Text Available ... body tissue through which the sound travels. A small amount of gel is put on the skin to allow the sound waves to travel from the transducer to the examined area within the body and then back again. Ultrasound ...

  6. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... body tissue through which the sound travels. A small amount of gel is put on the skin to allow the sound waves to travel from the transducer to the examined area within the body and then back again. Ultrasound ...

  7. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... the amplitude (loudness), frequency (pitch) and time it takes for the ultrasound signal to return from the area within the patient that is being examined to the transducer (the device placed on the patient's skin to send and ...

  8. Prostate Ultrasound

    Medline Plus

    Full Text Available ... the amplitude (loudness), frequency (pitch) and time it takes for the ultrasound signal to return from the area within the patient that is being examined to the transducer (the device placed on the patient's skin to send and ...

  9. Examination of a University-Affiliated Safe Ride Program

    Science.gov (United States)

    Gieck, D. Joseph; Slagle, David M.

    2010-01-01

    A university-affiliated safe ride program was evaluated to determine whether these programs can reduce drunk-driving related costs. Data was collected from 187 safe ride passengers during three nights of operation. Among the passengers, 93% were enrolled at a local University, 31% were younger than 21, and 40% reported a prior alcohol-related…

  10. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... Ultrasound - Pelvis Ultrasound imaging of the pelvis uses sound waves to produce pictures of the structures and ... pictures of the inside of the body using sound waves. Ultrasound imaging, also called ultrasound scanning or ...

  11. Prostate Ultrasound

    Medline Plus

    Full Text Available ... Z Ultrasound - Prostate Ultrasound of the prostate uses sound waves to produce pictures of a man’s prostate ... pictures of the inside of the body using sound waves. Ultrasound imaging, also called ultrasound scanning or ...

  12. Ultrasound -- Pelvis

    Science.gov (United States)

    ... endometrial polyps fibroids cancer, especially in patients with abnormal uterine bleeding Some physicians also use 3-D ultrasound or ... Obstetric Ultrasound Ultrasound - Prostate Kidney and Bladder Stones Abnormal Vaginal Bleeding Ovarian Cancer Images related to Ultrasound - Pelvis Sponsored ...

  13. Oral Anatomy Laboratory Examinations in a Physical Therapy Program

    Science.gov (United States)

    Fabrizio, Philip A.

    2013-01-01

    The process of creating and administering traditional tagged anatomy laboratory examinations is time consuming for instructors and limits laboratory access for students. Depending on class size and the number of class, sections, creating, administering, and breaking down a tagged laboratory examination may involve one to two eight-hour days.…

  14. Obstetrical ultrasound

    International Nuclear Information System (INIS)

    Bundy, A.L.

    1988-01-01

    The use of diagnostic ultrasound in obstetrics may provide fuel for legal action. While most legal implications of this relatively new imaging modality are purely speculative, some have already given rise to legal action. Several situations will likely provide a basis for the courts to find against the physician. The failure to perform a sonogram when clinically indicated will most likely be the strongest plaintiff argument. Other major concerns include the use and availability of state-of-the-art equipment, as well as interpretation of the scans by a trained physician. Obstetrical ultrasound is usually performed by a radiologist or obstetrician. However, many physicians performing these examinations have had little or no formal training in the field. While this is now being remedied by the respective board examines who require a certain amount of training, it may not be enough. When ultrasound-related cases reach the courts, the involved physicians will most likely be regarded as experts in the field and, therefore, will be held to a very high standard of care. This would be difficult to achieve without formal training. At the present time, the American Board of Radiology requires more training time in ultrasound than the American Board of Obstetrics and Gynecology

  15. THE DIAGNOSTIC VALUE OF CLINICAL EXAMINATION AND ULTRASOUND STUDY OF ENTHESES FOR EARLY DETECTION OF PSORIATIC AND RHEUMATOID ARTHRITIS: REMARC STUDY

    Directory of Open Access Journals (Sweden)

    Tatiana Viktorovna Korotaeva

    2013-01-01

    Full Text Available The diagnosis of enthesitis can help in differentiating early psoriatic arthritis (ePsA from early rheumatoid arthritis (eRA.Objective. To estimate the diagnostic value of detecting enthesitis during clinical examination and ultrasound in ePsA and eRA.Subjects and methods. The trial included 36 patients with ePsA and 33 with eRA. Entheses were evaluated using the Leeds Enthesitis Index (LEI: lateral humeral epicondyle and medial femoral condyle (MFC, Achilles tendon insertion site (ATAP, and plantar fascia (PF point on the right and on the left. Enthesitis (on ultrasound presented with thickening, reduced echo density, and vascularization at Doppler energy imaging. DAS, DAS28, SDAI, CDAI, M±SD, Me [25th, 75th percentile], t-test, Fisher's exact test, χ2test, U test, and Spearman correlation coefficients (R were calculated; the value p < 0.05 was considered statistically significant.Results. Clinical examination revealed enthesitis in 41.6% of the patients with ePsA and in 39.4% of those with eRA (p >0.05. No significant differences were found between ePsA and eRA according to LEI (0.5 [0; 2] and 1 [0; 2] and to LEI+PF (1 [0; 2] and 1 [0; 2], respectively. Enthesitis of MFC and PF was significantly more frequently detected in ePsA than in eRA – 12 (33.3%/2 (6.1% and 10 (27.8%/2 (6.1% patients, respectively. In eRA versus ePsA, enthesitis of MFC was more frequently found (16 (48.4% and 8 (22.2% patients, respectively. Ultrasound revealed no significant differences between the groups in enthesitis. In ePsA, there was a significant correlation between DAS, DAS28, SDAI, CDAI, LEI, and LEI+PF.Conclusion. Enthesis ultrasound cannot differentiate ePsA from eRA. Clinical examination more frequently detects enthesitis in the knee joints in eRA and in the calcaneal region in ePsA.

  16. Comprehensive Survey Results of Childhood Thyroid Ultrasound Examinations in Fukushima in the First Four Years After the Fukushima Daiichi Nuclear Power Plant Accident.

    Science.gov (United States)

    Suzuki, Shinichi; Suzuki, Satoru; Fukushima, Toshihiko; Midorikawa, Sanae; Shimura, Hiroki; Matsuzuka, Takashi; Ishikawa, Tetsuo; Takahashi, Hideto; Ohtsuru, Akira; Sakai, Akira; Hosoya, Mitsuaki; Yasumura, Seiji; Nollet, Kenneth E; Ohira, Tetsuya; Ohto, Hitoshi; Abe, Masafumi; Kamiya, Kenji; Yamashita, Shunichi

    2016-06-01

    Thyroid nodules and cancers are rare in children compared with adults. However, after the 1986 Chernobyl Nuclear Power Plant accident, a rapid increase in childhood thyroid cancer was observed. To avoid any confusion and misunderstanding of data obtained in Fukushima after the 2011 nuclear accident, baseline prevalence of thyroid nodules and cancers should be carefully assessed with standardized criteria systematically, and comprehensively applied to the population perceived to be at risk. Under the official framework of the Fukushima Health Management Survey, the thyroids of children in Fukushima were examined using ultrasound, and the results collected in the first four years after the nuclear accident were analyzed in order to establish a baseline prevalence of childhood thyroid abnormalities, especially cancer. Of 367,685 people aged 18 years or younger as of April 1, 2011, who were living in Fukushima Prefecture at the time of the accident, 300,476 underwent thyroid ultrasound screening. Of those, 2108 subjects with thyroid nodules were further examined using an advanced ultrasound instrument, with standardized criteria applied to determine the need for fine-needle aspiration cytology (FNAC). FNAC results determined the need for surgery and histological confirmation of the cytological diagnosis. Of the 2108 rescreened subjects, 543 underwent FNAC, of whom 113 were diagnosed with malignancy or suspected malignancy. Subsequently, 99 patients underwent surgical resection, revealing 95 cases of papillary thyroid cancer, three poorly differentiated cancers, and one benign nodule. The overall prevalence of childhood thyroid cancer in Fukushima was determined to be 37.3 per 100,000 with no significant differences between evacuated and non-evacuated areas. Thyroid cancer patients had external exposure estimates of detected in this four-year study in Fukushima can be attributed to mass screening. It clearly exceeds what is found incidentally anywhere else. Direct

  17. Examining Community-Engaged Scholarship in Public Administration Programs

    Science.gov (United States)

    Norvell, Katrina Herndon

    2010-01-01

    This study sought to broaden the understanding of the role that academic professions play in shaping the values and attitudes of faculty toward CES. This study explored faculty perceptions regarding the factors that encourage or dissuade them in the pursuit of CES within public administration programs. As a framework for research, a conceptual…

  18. Shooting with sound: optimizing an affordable ballistic gelatin recipe in a graded ultrasound phantom education program.

    Science.gov (United States)

    Tanious, Shariff F; Cline, Jamie; Cavin, Jennifer; Davidson, Nathan; Coleman, J Keegan; Goodmurphy, Craig W

    2015-06-01

    The goal of this study was to investigate the durability and longevity of gelatin formulas for the production of staged ultrasound phantoms for education. Gelatin phantoms were prepared from Knox gelatin (Kraft Foods, Northfield, IL) and a standard 10%-by-mass ordinance gelatin solution. Phantoms were durability tested by compressing to a 2-cm depth until cracking was visible. Additionally, 16 containers with varying combinations of phenol, container type, and storage location were tested for longevity against desiccation and molding. Once formulation was determined, 4 stages of phantoms from novice to clinically relevant were poured, and clinicians with ultrasound training ranked them on a 7-point Likert scale based on task difficulty, phantom suitability, and fidelity. On durability testing, the ballistic gelatin outperformed the Knox gelatin by more than 200 compressions. On longevity testing, gelatin with a 0.5% phenol concentration stored with a lid and refrigeration lasted longest, whereas containers without a lid had desiccation within 1 month, and those without phenol became moldy within 6 weeks. Ballistic gelatin was more expensive when buying in small quantities but was 7.4% less expensive when buying in bulk. The staged phantoms were deemed suitable for training, but clinicians did not consistently rank the phantoms in the intended order of 1 to 4 (44%). Refrigerated and sealed ballistic gelatin with phenol was a cost-effective method for creating in-house staged ultrasound phantoms suitable for large-scale ultrasound educational training needs. Clinician ranking of phantoms may be influenced by current training methods that favor biological tissue scanning as easier. © 2015 by the American Institute of Ultrasound in Medicine.

  19. Examining the sensitivity of ultrasound-guided large core biopsy for invasive breast carcinoma in a population screening programme

    International Nuclear Information System (INIS)

    Rouse, Hannah C.; Ussher, Simon; Cawson, Jennifer N.; Kavanagh, Anne M.

    2013-01-01

    To evaluate the sensitivity of ultrasound-guided core-needle biopsy (UCB) in invasive breast carcinoma and to establish causes of false-negative biopsy in a population screening programme. We identified 571 consecutive women diagnosed with surgically proven invasive breast cancer. Histology from 14-gauge UCB was compared with surgical histology to identify true-positive and false-negative ultrasound core biopsies. True-positive and false-negative groups were compared for tumour size and histology. On blinded review of UCB images and pathology reports from false negative (n=20) and a random sample of true-positive cases (n=80), we compared core sample number and needle visualisation in the lesion. Of 571 carcinomas sampled with UCB, 551 (96.5%) were true positive and 20 (3.5%) were false negative. The mean core number was 2.0 (range 1–3) for false negatives and 2.25 (range 1–4) for true positives (P=0.27). Mean tumour sizes were 13.3 and 16.2mm for the false-negative and true-positive groups, respectively (P=0.25). Tubular carcinomas represented 30% (6/20) of false-negative cases compared with 5.1% (28/551) of the true-positive cases (P<0.001). On blinded review, needle visualisation within the lesion was demonstrated in 47.4% (9/19) of false-negative cases and 76.3% (61/80) of true-positive cases (P=0.02).We demonstrated a sensitivity of 96.5% with a mean of 2.21 cores. False-negative results were more likely in the absence of post-fire needle position verification and with tubular carcinomas. Neither tumour size nor core number predicted diagnostic accuracy.

  20. Reliability of panoramic ultrasound imaging in simultaneously examining muscle size and quality of the hamstring muscles in young, healthy males and females.

    Science.gov (United States)

    Palmer, Ty B; Akehi, Kazuma; Thiele, Ryan M; Smith, Doug B; Thompson, Brennan J

    2015-03-01

    The purpose of this study was to examine the reliability of ultrasound (US) measures of cross-sectional area (CSA), muscle thickness (MT) and echo intensity (EI) of the hamstrings, with comparisons between males and females. In 20 healthy participants (10 males, 10 females), CSA, MT and EI were measured from panoramic US scans of the hamstrings on 2 separate days. The intra-class correlation coefficients and standard errors of measurement as a percentage of the mean for CSA, MT and EI ranged from 0.715 to 0.984 and from 3.145 to 12.541% in the males and from 0.724 to 0.977 and from 4.571 to 17.890% in the females, respectively. The males had greater CSAs and MTs and lower EIs than the females (p = 0.002-0.049), and significant relationships were observed between CSA and MT (r = 0.714-0.938, p ≤ 0.001-0.023). From an overall reliability standpoint, these findings suggest that panoramic US may be a reliable technique for examining muscle size and quality of the hamstrings in both males and females. Copyright © 2015 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.

  1. Application of ultrasound examination in tactical conditions illustrated with an example of the Field Hospital of the Polish Military Contingent in Afghanistan

    Directory of Open Access Journals (Sweden)

    Waldemar Machała

    2014-12-01

    Full Text Available It is assumed that tactical medicine encompasses all therapeutic activities performed by a military medical service during military and humanitarian missions. Its scope is only apparently limited by the standards which, when referred to the NATO member countries, have been collected in the Joint Theater Trauma System – Clinical Practice Guidelines. The stage-structured character of medical assistance and treatment of the wounded, injured and sick patients assumes that the scope of therapeutic activities performed at each stage is limited only to essential actions. Consequently, more injured patients may be saved – those for whom life-saving activities are performed prior to their transfer to a higher level. The second level is represented by a field hospital. Its first structure is the trauma room in which a rescue team saves and qualifies the injured for further medical activities. Each injured patient undergoes an eFAST ultrasound examination which allows for a quick decision about a surgical treatment to be provided. Moreover, this technique is helpful in vascular cannulation. The authors present their own experiences with using an ultrasound examination during the work in the Field Hospital of the Polish Military Contingent in Afghanistan.

  2. TMI-2 core-examination program: INEL facilities readiness study

    International Nuclear Information System (INIS)

    McLaughlin, T.B.

    1983-02-01

    This report reviews the capability and readiness of remote handling facilities at the Idaho National Engineering Laboratory (INEL) to receive, and store the TMI-2 core, and to examine and analyze TMI-2 core samples. To accomplish these objectives, the facilities must be able to receive commercial casks, unload canisters from the casks, store the canisters, open the canisters, handle the fuel debris and assemblies, and perform various examinations. The report identifies documentation, including core information, necessary to INEL before receiving the entire TMI-2 core. Also identified are prerequisites to INEL's receipt of the first canister: costs, schedules, and a preliminary project plan for the tasks

  3. Examining Understandings of Parent Involvement in Early Childhood Programs

    Science.gov (United States)

    Hilado, Aimee V.; Kallemeyn, Leanne; Phillips, Lauren

    2013-01-01

    The importance of parent involvement in children's development and learning is increasingly recognized in the research literature and in federal and state policies; however, no unified definition of parent involvement exists. This study examined different understandings and definitions of parent involvement in a sample of administrators of…

  4. The Nevada Proficiency Examination Program: Evaluating the Writing Samples.

    Science.gov (United States)

    Howard, Edward H.

    Writing tests are part of the mandated statewide proficiency examination in Nevada. The ninth-grade screening test and the eleventh-grade diploma-certifying test require that a student write a paragraph and a business letter, each on an assigned topic and each at an acceptable level of proficiency. Pilot tests, extended discussion, and statistical…

  5. Examining the Small Renewable Energy Power (SREP) Program in Malaysia

    Energy Technology Data Exchange (ETDEWEB)

    Sovacool, Benjamin K., E-mail: bsovacool@nus.edu.sg [Lee Kuan Yew School of Public Policy, National University of Singapore, 469C Bukit Timah Road, Singapore 259772 (Singapore); Drupady, Ira Martina [Lee Kuan Yew School of Public Policy, National University of Singapore, 469C Bukit Timah Road, Singapore 259772 (Singapore)

    2011-11-15

    The Small Renewable Energy Power (SREP) Program was the premier policy mechanism implemented by the national government to promote small-scale renewable electricity in Malaysia from 2001 to 2010. However, it managed meet less than 3 percent of its original goal by 2005. This study investigates what happened. More specifically, using a qualitative semi-structured interview approach with data presented in a narrative format, it answers the following five questions: (1) What are the primary energy policy and security challenges facing Malaysia? (2) What were the drivers behind the SREP in Malaysia? (3) What were the major benefits arising from the SREP? (4) What were the significant challenges to implementation? (5) What lessons or insights does the SREP offer for the study of energy policy design and implementation more generally? We find that the SREP failed to achieve its targets due to capacity caps, a lengthy approval process, lack of monitoring, exclusion of stakeholders, and few (if any) pre-feasibility studies. Other factors explaining its poor performance include opposition from the national utility Tenaga Nasional Berhad and electricity tariffs unmatched with true production costs. - Highlights: > The Small Renewable Energy Power Program aimed to install 500 MW by 2005. > It installed only 12 MW by December 2005. > This study investigates why the SREP failed to achieve its targets.

  6. Examining the Small Renewable Energy Power (SREP) Program in Malaysia

    International Nuclear Information System (INIS)

    Sovacool, Benjamin K.; Drupady, Ira Martina

    2011-01-01

    The Small Renewable Energy Power (SREP) Program was the premier policy mechanism implemented by the national government to promote small-scale renewable electricity in Malaysia from 2001 to 2010. However, it managed meet less than 3 percent of its original goal by 2005. This study investigates what happened. More specifically, using a qualitative semi-structured interview approach with data presented in a narrative format, it answers the following five questions: (1) What are the primary energy policy and security challenges facing Malaysia? (2) What were the drivers behind the SREP in Malaysia? (3) What were the major benefits arising from the SREP? (4) What were the significant challenges to implementation? (5) What lessons or insights does the SREP offer for the study of energy policy design and implementation more generally? We find that the SREP failed to achieve its targets due to capacity caps, a lengthy approval process, lack of monitoring, exclusion of stakeholders, and few (if any) pre-feasibility studies. Other factors explaining its poor performance include opposition from the national utility Tenaga Nasional Berhad and electricity tariffs unmatched with true production costs. - Highlights: → The Small Renewable Energy Power Program aimed to install 500 MW by 2005. → It installed only 12 MW by December 2005. → This study investigates why the SREP failed to achieve its targets.

  7. Preoperative ultrasound staging of the axilla make's peroperative examination of the sentinel node redundant in breast cancer: saving tissue, time and money.

    Science.gov (United States)

    Van Berckelaer, Christophe; Huizing, Manon; Van Goethem, Mireille; Vervaecke, Andrew; Papadimitriou, Konstantinos; Verslegers, Inge; Trinh, Bich X; Van Dam, Peter; Altintas, Sevilay; Van den Wyngaert, Tim; Huyghe, Ivan; Siozopoulou, Vasiliki; Tjalma, Wiebren A A

    2016-11-01

    To evaluate the role of preoperative axillary staging with ultrasound (US) and fine needle aspiration cytology (FNAC). Can we avoid intraoperative sentinel lymph node (SLN) examination, with an acceptable revision rate by preoperative staging? This study is based on the retrospective data of 336 patients that underwent US evaluation of the axilla as part of their staging. A FNAC biopsy was performed when abnormal lymph nodes were visualized. Patients with normal appearing nodes on US or a benign diagnostic biopsy had removal of the SLNs without intraoperative pathological examination. We calculated the sensitivity, specificity and accuracy of US/FNAC in predicting the necessity of an axillary lymphadenectomy. Subsequently we looked at the total cost and the operating time of 3 models. Model A is our study protocol. Model B is a theoretical protocol based on the findings of the Z0011 trial with only clinical preoperative staging and in Model C preoperative staging and intraoperative pathological examination were both theoretically done. sentinel node, staging, ultrasound, preoperative axillary staging, FNAC, axilla RESULTS: The sensitivity, specificity and accuracy are respectively 0.75 (0.66-0.82), 1.00 (0.99-1.00) and 0.92 (0.88-0.94). Only 26 out of 317 (8.2%) patients that successfully underwent staging needed a revision. The total cost of Model A was 1.58% cheaper than Model C and resulted in a decrease in operation time by 9,46%. The benefits compared with Model B were much smaller. Preoperative US/FNAC staging of the axillary lymph nodes can avoid intraoperative examination of the sentinel node with an acceptable revision rate. It saves tissue, reduces operating time and decreases healthcare costs in general. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  8. Using actual and ultrasound carcass information in beef genetic evaluation programs

    OpenAIRE

    Bertrand,Joseph Keith

    2009-01-01

    Increased movement toward alliances and grid pricing in the U.S. has led to an increase interest in genetic values for carcass traits. The literature suggests that carcass genetic values are an effective tool to enhance selection for carcass traits, and that it is possible to select sires within a breed that can increase marbling score without adversely affecting external fat thickness or percent retail product relative to the breed mean. Ultrasound has been investigated as a cheaper means of...

  9. Prehospital Ultrasound

    Directory of Open Access Journals (Sweden)

    Jen-Tang Sun

    2014-06-01

    Full Text Available Ultrasound is a commonly used diagnostic tool in clinical conditions. With recent developments in technology, use of portable ultrasound devices has become feasible in prehospital settings. Many studies also proved the feasibility and accuracy of prehospital ultrasound. In this article, we focus on the use of prehospital ultrasound, with emphasis on trauma and chest ultrasound.

  10. Children's (Pediatric) Abdominal Ultrasound Imaging

    Medline Plus

    Full Text Available ... image. Ultrasound examinations do not use ionizing radiation (as used in x-rays ), thus there is no ... structure and movement of the body's internal organs, as well as blood flowing through blood vessels. Ultrasound ...

  11. Research program plan. Non-destructive examination. Volume 4

    International Nuclear Information System (INIS)

    Muscara, J.

    1985-07-01

    Nondestructive examination/evaluation (NDE) of nuclear reactor components is required during fabrication, before service, and at regularly scheduled shutdowns for periodic inservice inspection (ISI). Any flaws produced during fabrication should be detected by the fabrication and preservice baseline examinations and components containing rejectable flaws should be repaired before the reactor enters service. The purpose of ISI is to ensure that any flaws which develop during service can be detected and evaluated and that unacceptable components are repaired or replaced to maintain safety, as well as to identify possible generic-type defects that may be present or developing in the remainder of the system or other similar systems so that timely corrective actions can be taken. The major thrusts of the research in ultrasonic testing for ISI are (1) to define the influence of inspection variables and procedures on inspection reliability and to determine the impact of inspection unreliability on system safety and (2) to study and evaluate improved techniques for reliable and accurate flaw detection and characterization. This research, therefore, has direct impact on evaluations of and improvements in reactor safety

  12. Mechanism of lumen gain with a novel rotational aspiration atherectomy system for peripheral arterial disease: examination by intravascular ultrasound.

    Science.gov (United States)

    Hassan, Ali H M; Ako, Junya; Waseda, Katsuhisa; Honda, Yasuhiro; Zeller, Thomas; Leon, Martin B; Fitzgerald, Peter J

    2010-01-01

    The purpose of this study was to evaluate the mechanism of luminal gain with a novel atheroablation system (Pathway PV) for the treatment of peripheral artery disease using intravascular ultrasound (IVUS). The atherectomy system is a rotational atherectomy device, which employs expandable rotating blades with ports that allow flushing and aspiration of the plaque material or thrombus. In this first-in-man clinical study, IVUS analysis was available in 6 patients with lower limb ischemia treated with this device. The treatment results were assessed using IVUS at pre and post atherectomy. Lumen beyond burr size (LBB) was defined as lumen gain divided by the estimated burr area determined by the burr-size. IVUS analysis was available in six patients (superficial femoral artery n=3, popliteal artery n=2, posterior tibial artery n=1). Atheroablation achieved a significant increase in lumen area (LA) (preintervention 3.9+/-0.4, postatheroablation 8.0+/-1.7 mm(2), Patherectomy device achieved significant luminal gain by debulking in the absence of vessel stretching. The LA was greater than burr-sized lumen expectancy at cross-sections along the treated segments, suggesting a complimentary role of aspiration in luminal gain in atherosclerotic peripheral artery lesions.

  13. Ultrafest: a novel approach to ultrasound in medical education leads to improvement in written and clinical examinations.

    Science.gov (United States)

    Connolly, Kiah; Beier, Lancelot; Langdorf, Mark I; Anderson, Craig L; Fox, John C

    2015-01-01

    Our objective was to evaluate the effectiveness of hands-on training at a bedside ultrasound (US) symposium ("Ultrafest") to improve both clinical knowledge and image acquisition skills of medical students. Primary outcome measure was improvement in multiple choice questions on pulmonary or Focused Assessment with Sonography in Trauma (FAST) US knowledge. Secondary outcome was improvement in image acquisition for either pulmonary or FAST. Prospective cohort study of 48 volunteers at "Ultrafest," a free symposium where students received five contact training hours. Students were evaluated before and after training for proficiency in either pulmonary US or FAST. Proficiency was assessed by clinical knowledge through written multiple-choice exam, and clinical skills through accuracy of image acquisition. We used paired sample t-tests with students as their own controls. Pulmonary knowledge scores increased by a mean of 10.1 points (95% CI [8.9-11.3], pknowledge scores increased by a mean of 7.5 points (95% CI [6.3-8.7] pknowledge, but is limited in achieving image acquisition for pulmonary and FAST US assessments. US training external to official medical school curriculum may augment students' education.

  14. 46 CFR 176.630 - The Alternative Hull Examination (AHE) Program application.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 7 2010-10-01 2010-10-01 false The Alternative Hull Examination (AHE) Program... PASSENGER VESSELS (UNDER 100 GROSS TONS) INSPECTION AND CERTIFICATION Hull and Tailshaft Examinations § 176.630 The Alternative Hull Examination (AHE) Program application. If your vessel meets the eligibility...

  15. 46 CFR 176.650 - Alternative Hull Examination Program options: Divers or underwater ROV.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 7 2010-10-01 2010-10-01 false Alternative Hull Examination Program options: Divers or...) SMALL PASSENGER VESSELS (UNDER 100 GROSS TONS) INSPECTION AND CERTIFICATION Hull and Tailshaft Examinations § 176.650 Alternative Hull Examination Program options: Divers or underwater ROV. To complete the...

  16. 46 CFR 115.650 - Alternative Hull Examination (AHE) Program options: Divers or underwater ROV.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 4 2010-10-01 2010-10-01 false Alternative Hull Examination (AHE) Program options... MORE THAN 49 PASSENGERS INSPECTION AND CERTIFICATION Hull and Tailshaft Examinations § 115.650 Alternative Hull Examination (AHE) Program options: Divers or underwater ROV. To complete your underwater...

  17. Slurry steam generator program and baseline eddy current examination

    International Nuclear Information System (INIS)

    Clark, R.A.; Doctor, P.G.

    1985-01-01

    The Steam Generator Group Project was initiated in January 1982 with formation of consortium including NRC, EPRI, Japanese, French, and Italian participants. The project utilizes a retired-from-service nuclear steam generator established in a specially designed facility which houses the unit in its normal vertical operating position. The most important objectives deal with validation of nondestructive examination (NDE) techniques used to characterize steam generators during service. This research generator offers the first opportunity to characterize a statistically significant number of service-induced defects nondestructively followed by destructive metallographic confirmation. The project seeks to establish the reliability of defect detection and the accuracy of sizing defects via current state-of-the-art NDE. Other service degraded tubes will be burst tested to establish remaining service integrity. The integrity information and NDE reliability results will serve as inputs to establish a model for steam generator in-service inspections, and provide a data base for evaluation of tube plugging criteria. In addition to NDE validation goals, the project will use the service degraded generator as a specimen for demonstration/proof testing of repair and maintenance techniques, including chemical cleaning/decontamination technologies. In addition to the efforts associated with NDE, a multitude of other project tasks have continued through 1984, and results are presented

  18. Surry steam generator program and baseline eddy current examination

    International Nuclear Information System (INIS)

    Clark, R.A.; Doctor, P.G.

    1985-01-01

    The Steam Generator Group Project was initiated in January 1982 with formation of consortium including NRC, EPRI, Japanese, French, and Italian participants. The project utilizes a retired-from-service nuclear steam generator established in a specially designed facility which houses the unit in its normal vertical operating position. The most important objectives deal with validation of nondestructive examination (NDE) techniques used to characterize steam generators during service. This research generator offers the first opportunity to characterize a statistically significant number of service-induced defects nondestructively followed by destructive metallographic confirmation. The project seeks to establish the reliability of defect detection and the accuracy of sizing defects via current state-of-the-art NDE. Other service degraded tubes will be burst tested to establish remaining service integrity. The integrity information and NDE reliability results will serve as inputs to establish a model for steam generator in-service inspections, and provide a data base for evaluation of tube plugging criteria. In addition to NDE validation goals, the project will use the service degraded generator as a specimen for demonstration/proof testing of repair and maintenance techniques, including chemical cleaning/decontamination technologies. In addition to the efforts associated with NDE, a multitude of other project tasks have continued through 1984, and results are presented

  19. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... three types of pelvic ultrasound: abdominal, vaginal (for women), and rectal (for men). These exams are frequently ... pelvic ultrasound: abdominal ( transabdominal ) vaginal ( transvaginal / endovaginal ) for women rectal ( transrectal ) for men A Doppler ultrasound exam ...

  20. Ultrafest: A Novel Approach to Ultrasound in Medical Education Leads to Improvement in Written and Clinical Examinations

    Directory of Open Access Journals (Sweden)

    Langdorf, Mark I.

    2014-12-01

    Full Text Available Introduction: Our objective was to evaluate the effectiveness of hands-on training at a bedside ultrasound (US symposium (“Ultrafest” to improve both clinical knowledge and image acquisition skills of medical students. Primary outcome measure was improvement in multiple choice questions on pulmonary or Focused Assessment with Sonography in Trauma (FAST US knowledge. Secondary outcome was improvement in image acquisition for either pulmonary or FAST. Methods: Prospective cohort study of 48 volunteers at “Ultrafest,” a free symposium where students received five contact training hours. Students were evaluated before and after training for proficiency in either pulmonary US or FAST. Proficiency was assessed by clinical knowledge through written multiple-choice exam, and clinical skills through accuracy of image acquisition. We used paired sample t-tests with students as their own controls. Results: Pulmonary knowledge scores increased by a mean of 10.1 points (95% CI [8.9-11.3], p<0.00005, from 8.4 to a posttest average of 18.5/21 possible points. The FAST knowledge scores increased by a mean of 7.5 points (95% CI [6.3-8.7] p<0.00005, from 8.1 to a posttest average of 15.6/ 21. We analyzed clinical skills data on 32 students. The mean score was 1.7 pretest and 4.7 posttest of 12 possible points. Mean improvement was 3.0 points (p<0.00005 overall, 3.3 (p=0.0001 for FAST, and 2.6 (p=0.003 for the pulmonary US exam. Conclusion: This study suggests that a symposium on US can improve clinical knowledge, but is limited in achieving image acquisition for pulmonary and FAST US assessments. US training external to official medical school curriculum may augment students’ education. [West J Emerg Med. 2015;16(1:143–148.

  1. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... most ultrasound exams, you will be positioned lying face-up on an examination table that can be ... in a known abnormality can be monitored over time. Follow-up examinations are sometimes the best way ...

  2. Microwave and ultrasound-assisted synthesis of poly(vinyl chloride)/riboflavin modified MWCNTs: Examination of thermal, mechanical and morphology properties.

    Science.gov (United States)

    Abdolmaleki, Amir; Mallakpour, Shadpour; Azimi, Faezeh

    2018-03-01

    This study focused on the preparation and investigation of physicochemical features of new poly(vinyl chloride) (PVC) nanocomposites (NCs) including different amounts of carboxylated multi-walled carbon nanotubes (MWCNTs-COOH) functionalized with riboflavin (RIB). Firstly, to increase the hydrophilicity of MWCNTs, the surface of them was functionalized by incorporating and formation of ester groups with RIB as a low cost and environmentally friendly biomolecule through ultrasound and microwave irradiations. Afterwards, PVC/RIB-MWCNTs NCs were fabricated via the solution casting and ultrasonic dispersion methods. Prepared NCs were examined by X-ray diffraction, thermogravimetric analysis, field emission scanning electron microscopy, transmission electron micrograph, and Raman spectroscopy. The PVC/RIB-MWCNTs NCs (12wt%) showed the higher mechanical and thermal behavior as compared to other concentration of MWCNTs. Copyright © 2017 Elsevier B.V. All rights reserved.

  3. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... through blood vessels. Ultrasound imaging is a noninvasive medical test that helps physicians diagnose and treat medical conditions. There are three types of pelvic ultrasound: ...

  4. An augmented audit program for assuring radiation safety during radiographic examination operations

    International Nuclear Information System (INIS)

    Jervey, R.A. Jr.; Papin, P.J.

    1993-01-01

    Auditing a gamma radiography program is required as part of the authorizing license. Checklists and cursory reviews are the typical approach to addressing program requirements. A more proactive approach is recommended. The audit program described was prepared for a specific set of operating conditions but can be applied to any given program. Improvements in the effectiveness of the radiography safety program can be made with additional examination and emphasis on direct observation of licensed activities

  5. Vascular ultrasound.

    Science.gov (United States)

    Pilcher, D B; Ricci, M A

    1998-04-01

    Surgeon-interpreted diagnostic ultrasound has become the preferred screening test and often the definitive test for the diagnosis of arterial stenosis, aneurysm, and venous thrombosis. As a modality for surveillance, its noninvasive quality makes it particularly appealing as the test of choice to screen patients for abdominal aortic aneurysms or to perform follow-up examinations on those patients with a carotid endartectomy or in situ bypass grafts. The increasing reliance on intraoperative duplex imaging of vascular procedures demands that the surgeon learn the skills to perform the studies without a technologist or radiologist to interpret the examination.

  6. 46 CFR 71.50-19 - The Alternative Hull Examination (AHE) Program application.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 3 2010-10-01 2010-10-01 false The Alternative Hull Examination (AHE) Program...) PASSENGER VESSELS INSPECTION AND CERTIFICATION Drydocking § 71.50-19 The Alternative Hull Examination (AHE... apply to the AHE Program. You must submit an application at least 90 days before the requested hull...

  7. At What Cost? Examining the Cost Effectiveness of a Universal Social-Emotional Learning Program

    Science.gov (United States)

    Hunter, Leah J.; DiPerna, James C.; Hart, Susan Crandall; Crowley, Max

    2018-01-01

    Although implementation of universal social-emotional learning programs is becoming more common in schools, few studies have examined the cost-effectiveness of such programs. As such, the purpose of this article is two fold. First, we provide an overview of cost-effectiveness methods for school-based programs, and second, we share results of a…

  8. An Examination of Program Selection Criteria for Part-Time MBA Students

    Science.gov (United States)

    Colburn, Michael; Fox, Daniel E.; Westerfelt, Debra Kay

    2011-01-01

    Prospective graduate students select a graduate program as a result of a multifaceted decision-making process. This study examines the selection criteria that part-time MBA students used in selecting a program at a private university. Further, it analyzes the methods by which the students first learned of the MBA program. The authors posed the…

  9. Children's (Pediatric) Abdominal Ultrasound Imaging

    Medline Plus

    Full Text Available ... waves from passing into your body. The sonographer (ultrasound technologist) or radiologist then places the transducer on the skin in various locations, sweeping over the area of interest or angling the ... ultrasound images are reviewed. An ultrasound examination is usually ...

  10. Developing an emergency ultrasound app

    DEFF Research Database (Denmark)

    Foss, Kim Thestrup; Subhi, Yousif; Aagaard, Rasmus

    2015-01-01

    Focused emergency ultrasound is rapidly evolving as a clinical skill for bedside examination by physicians at all levels of education. Ultrasound is highly operator-dependent and relevant training is essential to ensure appropriate use. When supplementing hands-on focused ultrasound courses, e-le...

  11. The diagnostic accuracy of physical examination compared to lung ultrasound for determining lung congestion in hemodialysis patients who have reached their dry weight

    Science.gov (United States)

    Rahardjo, K. D.; Dharmaeizar; Nainggolan, G.; Harimurti, K.

    2017-08-01

    Research has shown that hemodialysis patients with lung congestion have high morbidity and mortality. Patients were assumed to be free of lung congestion if they had reached their post-dialysis dry weight. Most often, to determine if the patient was free of lung congestion, physical examination was used. However, the accuracy of physical examination in detecting lung congestion has not been established. To compare the capabilities of physical examination and lung ultrasound in detection of lung congestion, cross-sectional data collection was conducted on hemodialysis patients. Analysis was done to obtain proportion, sensitivity, specificity, positive predictive value, negative predictive value, and positive likelihood ratio. Sixty patients participated in this study. The inter observer variation of 20 patients revealed a kappa value of 0.828. When all 60 patients were taken into account, we found that 36 patients (57.1%) had lung congestion. Mild lung congestion was found in 24 (38.1%), and 12 (19%) had a moderate degree of congestion. In the analysis comparing jugular venous pressure to lung ultrasound, we found that sensitivity was 0.47 (0.31-0.63), specificity was 0.73 (0.54-0.86), positive predictive value (PPV) was 0.51 (0.36-0.67), negative predictive value (NPV) was 0.70 (0.49-0.84), positive likelihood ratio (PLR) was 1.75 (0.88-3.47), and the negative likelihood ratio (NLR) was 0.72 (0.47-1.12). In terms of lung auscultation, we found that sensitivity was 0.56 (0.39-0.71), specificity was 0.54 (0.35-0.71), PPV was 0.61 (0.44-0.76), NPV was 0.48 (0.31-0.66), PLR was 1.21 (0.73-2.0), and NLR was 0.82 (0.49-1.38). The results of our study showed that jugular venous distention and lung auscultation examination are not reliable means of detecting lung congestion.

  12. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... Radiation Therapy for Gynecologic Cancers Radiation Therapy for Prostate Cancer top of page This page was reviewed on ... Abdomen Children's (Pediatric) Ultrasound - Abdomen Obstetric Ultrasound Ultrasound - Prostate Kidney and Bladder Stones Abnormal Vaginal Bleeding ... Images related to Ultrasound - Pelvis Sponsored by Please ...

  13. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... endometrial polyps fibroids cancer, especially in patients with abnormal uterine bleeding Some physicians also use 3-D ultrasound or ... Obstetric Ultrasound Ultrasound - Prostate Kidney and Bladder Stones Abnormal Vaginal Bleeding Ovarian Cancer Images related to Ultrasound - Pelvis Sponsored ...

  14. Research and examinations at the Tono Mines. Fiscal year's programs (Heisei 12 fiscal year). Technical report

    International Nuclear Information System (INIS)

    2000-04-01

    This program showed details on the research and examination program of the Japan Nuclear Cycle Development Institute to be carried out at the Tono Mines in the Heisei 12 fiscal year, according to the 'Fundamental program on research and examinations at the Tono Mines' established on October, 1998. And, this program is carried out under an aim at understanding of transfer and delay performance of materials in deposit rocks with uranium and geological features such as fault, and at development of technology and apparatus for general investigation and evaluation of geological environment, as a stratum science research. Here were described on research and examination of mechanical stability on the rock board, research and examination of geological environment around a tunnel, research and examination of material transfer in the rock board, and research and examination of the Tsukiyoshi stratum abstractly before 1999 and in details at 2000 fiscal years. (G.K.)

  15. "PERLE bedside-examination-course for candidates in state examination" - Developing a training program for the third part of medical state examination (oral examination with practical skills).

    Science.gov (United States)

    Karthaus, Anne; Schmidt, Anita

    2016-01-01

    In preparation for the state examination, many students have open questions and a need for advice. Tutors of the Skills Lab PERLE-"Praxis ERfahren und Lernen" (experiencing and learning practical skills) have developed a new course concept to provide support and practical assistance for the examinees. The course aims to familiarize the students with the exam situation in order to gain more confidence. This enables the students to experience a confrontation with the specific situation of the exam in a protected environment. Furthermore, soft skills are utilized and trained. Concept of the course: The course was inspired by the OSCE-model (Objective Structured Clinical Examination), an example for case-based learning and controlling. Acquired knowledge can be revised and extended through the case studies. Experienced tutors provide assistance in discipline-specific competencies, and help in organizational issues such as dress code and behaviour. Evaluation of the course: An evaluation was conducted by the attending participants after every course. Based on this assessment, the course is constantly being developed. In March, April and October 2015 six courses, with a total of 84 participants, took place. Overall 76 completed questionnaires (91%) were analysed. Strengths of the course are a good tutor-participants-ratio with 1:4 (1 Tutor provides guidance for 4 participants), the interactivity of the course, and the high flexibility in responding to the group's needs. Weaknesses are the tight schedule, and the currently not yet performed evaluation before and after the course. In terms of "best practise", this article shows an example of how to offer low-cost and low-threshold preparation for the state examination.

  16. Intra­‑abdominal adhesions in ultrasound. Part I: The visceroperitoneal bordeline, anatomy and the method of examination

    Directory of Open Access Journals (Sweden)

    Andrzej Smereczyński

    2012-12-01

    Full Text Available It needs to be emphasized that ultrasonography is a primary test performed in order to evaluate the abdominal wall and structures located in their vicinity. It allows for the determination of the anatomy and lesions in this localization. Thorough knowledge con‑ cerning the ultrasound anatomy of the tested structures constitutes a basis of all diagnos‑ tic successes. Therefore, this part of the article is devoted to this subject matter. The pos‑ sibility to diagnose intra-abdominal adhesions with ultrasound is underestimated and rarely used. The aim of this paper is to discuss and document the ultrasound anatomy of the posterior surface of the abdominal wall as well as to present techniques directed at the detection of adhesions, in particular the visceroperitoneal ones. The posterior surface of the abdominal wall constitutes an extensive tissue area of complex structure, with folds and ligaments surrounded by various amounts of the epiperitoneal fat. In some places, this tissue separates the components of the fascia and peritoneum complex. The ultra‑ sound manifestation of this complex is two hyperechogenic lines placed parallelly to each other in the places where they are not separated by the accumulated adipose tissue. Another factor which separates the peritoneum from the viscera is of dynamic character. It is a so-called visceral slide induced by easy or deep breathing. Its size should not be lower than 1 cm and the deflections gradually and symmetrically diminish from the epi‑ gastric to hypogastric region. Last but not least, the evaluation of the reciprocal relation of the abdominal wall with viscera may be aided by rhythmical manual compressions on the abdominal wall (ballottement sign performed below the applied ultrasound trans‑ ducer. During this test, the size of the visceral slide in relation to the abdominal wall is observed. The maneuver is usually performed in uncooperative patients or those with shallow breath. The

  17. Post-irradiation examination and R and D programs using irradiated fuels at KAERI

    International Nuclear Information System (INIS)

    Chun, Yong Bum; Min, Duck Kee; Kim, Eun Ka and others

    2000-12-01

    This report describes the Post-Irradiation Examination(PIE) and R and D programs using irradiated fuels at KAERI. The objectives of post-irradiation examination (PIE) for the PWR irradiated fuels, CANDU fuels, HANARO fuels and test fuel materials are to verify the irradiation performance and their integrity as well as to construct a fuel performance data base. The comprehensive utilization program of the KAERI's post-irradiation examination related nuclear facilities such as Post-Irradiation Examination Facility (PIEF), Irradiated Materials Examination Facility (IMEF) and HANARO is described

  18. Post-irradiation examination and R and D programs using irradiated fuels at KAERI

    International Nuclear Information System (INIS)

    Chun, Yong Bum; So, Dong Sup; Lee, Byung Doo; Lee, Song Ho; Min, Duck Kee

    2001-09-01

    This report describes the Post-Irradiation Examination(PIE) and R and D programs using irradiated fuels at KAERI. The objectives of post-irradiation examination (PIE) for the PWR irradiated fuels, CANDU fuels, HANARO fuels and test fuel materials are to verify the irradiation performance and their integrity as well as to construct a fuel performance data base. The comprehensive utilization program of the KAERI's post-irradiation examination related nuclear facilities such as Post-Irradiation Examination Facility (PIEF), Irradiated Materials Examination Facility (IMEF) and HANARO is described

  19. Fetal MRI for characterising a variety of posterior fossa anomalies suspected on 3rd trimester ultrasound examination – a short series of four cases

    Directory of Open Access Journals (Sweden)

    Amaresh Indravadan Ranchod

    2012-02-01

    Full Text Available Fetal MRI is increasingly being used to more accurately assess abnormalities detected on screening ultrasound. This procedure is more pertinent when the initial ultrasound is done late in the third trimester and when the abnormality involves the posterior fossa of the brain. Four cases with a variety of unusual posterior fossa anomalies are presented.

  20. 46 CFR 115.630 - The Alternative Hull Examination (AHE) Program application.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 4 2010-10-01 2010-10-01 false The Alternative Hull Examination (AHE) Program... PASSENGERS INSPECTION AND CERTIFICATION Hull and Tailshaft Examinations § 115.630 The Alternative Hull... hull examination date to the Officer in Charge, Marine Inspection (OCMI) who will oversee the survey...

  1. Relationship Between Physician Assistant Program Length and Physician Assistant National Certifying Examination Pass Rates.

    Science.gov (United States)

    Colletti, Thomas P; Salisbury, Helen; Hertelendy, Attila J; Tseng, Tina

    2016-03-01

    This study was conducted to examine the relationship between physician assistant (PA) educational program length and PA programs' 5-year average Physician Assistant National Certifying Examination (PANCE) first-time pass rates. This was a retrospective correlational study that analyzed previously collected data from a nonprobability purposive sample of accredited PA program Web sites. Master's level PA programs (n = 108) in the United States with published average PANCE scores for 5 consecutive classes were included. Provisional and probationary programs were excluded (n = 4). Study data were not normally distributed per the Kolmogorov-Smirnov test, P = .00. There was no relationship between program length and PANCE pass rates, ρ (108) = -0.04, P = .68. Further analyses examining a possible relationship between program phase length (didactic and clinical) and PANCE pass rates also demonstrated no differences (ρ [107] = -0.05, P = .60 and ρ [107] = 0.02, P = .80, respectively). The results of this study suggest that shorter length PA programs perform similarly to longer programs in preparing students to pass the PANCE. In light of rapid expansion of PA educational programs, educators may want to consider these findings when planning the length of study for new and established programs.

  2. Utility of compact ultrasound in a mass surgical selection program in Africa: experience of a sonologist at the MV Africa Mercy Hospital Ship's screening day.

    Science.gov (United States)

    Harris, Robert D; Parker, Gary

    2015-02-01

    Compact ultrasound (US) was introduced in an austere setting with no other available imaging for an annual mass surgical screening day. Compact US examinations were performed on 25 patients from more than 7000 potential patients, as deemed possibly useful by the screening surgeons. Of the 20 patients with recorded data, compact US was helpful in 14 of 20 as a decision-making tool, obviating computed tomography for preoperative planning. Compact US was helpful in most cases, saving resources (computed tomography), technologist time, and radiation risk in this select population. © 2015 by the American Institute of Ultrasound in Medicine.

  3. Optimizing Violence Prevention Programs: An Examination of Program Effectiveness among Urban High School Students

    Science.gov (United States)

    Thompkins, Amanda C.; Chauveron, Lisa M.; Harel, Ofer; Perkins, Daniel F.

    2014-01-01

    Background: While demand for youth violence prevention programs increases, the ability of the school-day schedule to accommodate their time requirements has diminished. Viable school-based prevention programs must strike a balance between brevity and effectiveness. This article reports results from an effectiveness trial of a 12-session…

  4. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... organs and to examine a baby in pregnant women and the brain and hips in infants. It’s ... modality for the diagnosis and monitoring of pregnant women and their unborn babies. Ultrasound provides real-time ...

  5. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... heartbeat. top of page What are some common uses of the procedure? Ultrasound examinations can help to ... is done because a potential abnormality needs further evaluation with additional views or a special imaging technique. ...

  6. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... needles are used to sample cells from an abnormal area for laboratory testing. image the breasts and ... of organs, tissues, and vessels or to detect abnormal masses, such as tumors. In an ultrasound examination, ...

  7. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... heartbeat. top of page What are some common uses of the procedure? Ultrasound examinations can help to ... community, you can search the ACR-accredited facilities database . This website does not provide cost information. The ...

  8. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... organs and to examine a baby in pregnant women and the brain and hips in infants. It’s ... Transvaginal ultrasound. The transducer is inserted into a woman's vagina to view the uterus and ovaries. top ...

  9. CHIT: a cost accounting program for postirradiation examinations of fast breeder reactor materials

    International Nuclear Information System (INIS)

    Phillips, J.R.; Dowler, K.E.

    1975-09-01

    CHIT is the Los Alamos Scientific Laboratory's cost accounting computer program for nondestructive and destructive examinations of irradiated fuel pins. The program allows immediate retrieval of fuel pin examination information and provides itemized listings for completed and projected fuel pin examinations, detailed cost accounting summaries for each investigator, fuel pin examinations during a specified time interval, and various subsets of the information. CHIT has been in successful operation for the past two years, providing precise information on cost accounting more efficiently than possible with a manual technique

  10. A Qualitative Approach to Examining Knowledge Sharing in Iran Tax Administration Reform Program

    Directory of Open Access Journals (Sweden)

    Mehdi Shami Zanjanie

    2012-02-01

    Full Text Available The paper aims to examine knowledge sharing infrastructure of "Iran Tax Administration Reform Program". The qualitative approach by using case study method was applied in this research. In order to meet the research goal, four infrastructural dimensions of knowledge sharing were studied: leadership & strategy, culture, structure, and information technology. To the authors’ knowledge, this was maybe the first paper which examined knowledge sharing infrastructure in programs environment

  11. 46 CFR 71.50-31 - Continued participation in the Alternative Hull Examination (AHE) program.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 3 2010-10-01 2010-10-01 false Continued participation in the Alternative Hull... the Alternative Hull Examination (AHE) program. (a) To continue to participate in the AHE Program, vessel operators must conduct an annual hull condition assessment. At a minimum, vessel operators must...

  12. Teaming up for Literacy: Examining Participants' Contributions to a Collaborative Family-Based Program

    Science.gov (United States)

    Kumar, Tracey

    2016-01-01

    This study of participants' contributions to a university-based family literacy program was informed by both "funds of knowledge" (Moll, 1992) and "multiple literacies" (Auerbach, 1995). The study examined participants' contributions to the design, implementation, and evaluation of a university-based family literacy program. In…

  13. Simulation-based point-of-care ultrasound training

    DEFF Research Database (Denmark)

    Jensen, J K; Dyre, L; Jørgensen, M E

    2018-01-01

    before being performed on actual patients. The aim of this study was to investigate the learning curves for novices training the FAST protocol on a virtual-reality simulator. METHODS: Ultrasound novices (N = 25) were instructed to complete a FAST training program on a virtual-reality ultrasound simulator....... Participants were instructed to continue training until they reached a previously established mastery learning level, which corresponds to the performance level of a group of ultrasound experts. Performance scores and time used during each FAST examination were used to determine participants' learning curves....... RESULTS: The participants attained the mastery learning level within a median of three (range two to four) attempts corresponding to a median of 1 h 46 min (range 1 h 2 min to 3 h 37 min) of simulation training. The ultrasound novices' examination speed improved significantly with training, and continued...

  14. TMI-2 accident evaluation program sample acquisition and examination plan. Executive summary

    International Nuclear Information System (INIS)

    Russell, M.L.; McCardell, R.K.; Broughton, J.M.

    1985-12-01

    The purpose of the TMI-2 Accident Evaluation Program Sample Acquisition and Examination (TMI-2 AEP SA and E) program is to develop and implement a test and inspection plan that completes the current-condition characterization of (a) the TMI-2 equipment that may have been damaged by the core damage events and (b) the TMI-2 core fission product inventory. The characterization program includes both sample acquisitions and examinations and in-situ measurements. Fission product characterization involves locating the fission products as well as determining their chemical form and determining material association

  15. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... diagnose symptoms experienced by women such as: pelvic pain abnormal vaginal bleeding other menstrual problems Ultrasound exams ... pelvic ultrasound can help evaluate: pelvic masses pelvic pain ambiguous genitalia and anomalies of pelvic organs early ...

  16. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... size, shape and consistency (whether the object is solid or filled with fluid). In medicine, ultrasound is ... ultrasound, measures the direction and speed of blood cells as they move through vessels. The movement of ...

  17. Prostate Ultrasound

    Medline Plus

    Full Text Available ... pictures of a man’s prostate gland and to help diagnose symptoms such as difficulty urinating or an ... Ultrasound imaging is a noninvasive medical test that helps physicians diagnose and treat medical conditions. Prostate ultrasound, ...

  18. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... by women such as: pelvic pain abnormal vaginal bleeding other menstrual problems Ultrasound exams also help identify: ... fibroids cancer, especially in patients with abnormal uterine bleeding Some physicians also use 3-D ultrasound or ...

  19. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... internal organs, as well as blood flowing through blood vessels. Ultrasound imaging is a noninvasive medical test that helps physicians diagnose and treat medical conditions. There are three types of pelvic ultrasound: abdominal ( transabdominal ) vaginal ( transvaginal / endovaginal ) ...

  20. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... There are three types of pelvic ultrasound: abdominal, vaginal (for women), and rectal (for men). These exams ... are three types of pelvic ultrasound: abdominal ( transabdominal ) vaginal ( transvaginal / endovaginal ) for women rectal ( transrectal ) for men ...

  1. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... the procedure? In women, a pelvic ultrasound is most often performed to evaluate the: uterus cervix ovaries ... page How is the procedure performed? Transabdominal: For most ultrasound exams, you will be positioned lying face- ...

  2. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... is used to evaluate the: bladder seminal vesicles prostate Transrectal ultrasound, a special study usually done to provide detailed evaluation of the prostate gland, involves inserting a specialized ultrasound transducer into ...

  3. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... Obstetric Ultrasound Ultrasound - Prostate Kidney and Bladder Stones Abnormal Vaginal Bleeding ... questions or for a referral to a radiologist or other physician. To locate a medical imaging or radiation oncology provider in your community, you ...

  4. Prostate Ultrasound

    Medline Plus

    Full Text Available ... top of page What are the benefits vs. risks? Benefits Ultrasound is widely available, easy-to-use ... procedures such as needle biopsies and fluid aspiration. Risks For standard diagnostic ultrasound , there are no known ...

  5. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... insertion. top of page How does the procedure work? Ultrasound imaging is based on the same principles ... modality for the diagnosis and monitoring of pregnant women and their unborn babies. Ultrasound provides real-time ...

  6. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... ovarian cysts and uterine fibroids ovarian or uterine cancers A transvaginal ultrasound is usually performed to view the endometrium (the lining of the uterus) and the ovaries. Transvaginal ultrasound also evaluates the myometrium (muscular walls ...

  7. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... needles are used to extract a sample of cells from organs for laboratory testing. Doppler ultrasound images ... ultrasound, measures the direction and speed of blood cells as they move through vessels. The movement of ...

  8. Prostate Ultrasound

    Medline Plus

    Full Text Available ... to-use and less expensive than other imaging methods. Ultrasound imaging uses no ionizing radiation. Ultrasound scanning ... radiation oncology provider in your community, you can search the ACR-accredited facilities database . This website does ...

  9. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... Ultrasound is the preferred imaging modality for the diagnosis and monitoring of pregnant women and their unborn ... sexes without x-ray exposure. Risks For standard diagnostic ultrasound , there are no known harmful effects on ...

  10. Prostate Ultrasound

    Medline Plus

    Full Text Available ... patient. Because ultrasound images are captured in real-time, they can show the structure and movement of ... test result. difficulty urinating. Because ultrasound provides real-time images, it also can be used to guide ...

  11. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... patient. Because ultrasound images are captured in real-time, they can show the structure and movement of ... help to distract the child and make the time pass quickly. The ultrasound exam room may have ...

  12. Prostate Ultrasound

    Medline Plus

    Full Text Available ... Ultrasound provides real-time imaging, making it a good tool for guiding minimally invasive procedures such as ... bowel (rectum) removed during prior surgery are not good candidates for ultrasound of the prostate gland because ...

  13. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... Imaging? Ultrasound waves are disrupted by air or gas; therefore ultrasound is not an ideal imaging technique ... page Additional Information and Resources RTAnswers.org Radiation Therapy for Gynecologic Cancers Radiation Therapy for Prostate Cancer ...

  14. Prostate Ultrasound

    Medline Plus

    Full Text Available ... ultrasound images are captured in real-time, they can show the structure and movement of the body's ... Because ultrasound provides real-time images, it also can be used to guide procedures such as needle ...

  15. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... investigation of the uterine cavity . Three-dimensional (3-D) ultrasound permits evaluation of the uterus and ovaries ... abnormal uterine bleeding Some physicians also use 3-D ultrasound or sonohysterography for patients with infertility. In ...

  16. Prostate Ultrasound

    Medline Plus

    Full Text Available ... and produces pictures of the inside of the body using sound waves. Ultrasound imaging, also called ultrasound ... from the probe through the gel into the body. The transducer collects the sounds that bounce back ...

  17. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... and produces pictures of the inside of the body using sound waves. Ultrasound imaging, also called ultrasound ... from the probe through the gel into the body. The transducer collects the sounds that bounce back ...

  18. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... object is solid or filled with fluid). In medicine, ultrasound is used to detect changes in appearance, ... have special pediatric considerations. The teddy bear denotes child-specific content. Related Articles and Media Sonohysterography Ultrasound - ...

  19. Obstetrical Ultrasound

    Science.gov (United States)

    ... heartbeat can be seen as an ongoing ultrasound movie. Ultrasound devices also use Doppler, a special application ... the possible charges you will incur. Web page review process: This Web page is reviewed regularly by ...

  20. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... insertion. top of page How does the procedure work? Ultrasound imaging is based on the same principles ... have special pediatric considerations. The teddy bear denotes child-specific content. Related Articles and Media Sonohysterography Ultrasound - ...

  1. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... menstrual problems Ultrasound exams also help identify: palpable masses such as ovarian cysts and uterine fibroids ovarian ... In children, pelvic ultrasound can help evaluate: pelvic masses pelvic pain ambiguous genitalia and anomalies of pelvic ...

  2. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... and development of an embryo or fetus during pregnancy. See the Obstetrical Ultrasound page for more information . ... object is solid or filled with fluid). In medicine, ultrasound is used to detect changes in appearance, ...

  3. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... ultrasound: abdominal, vaginal (for women), and rectal (for men). These exams are frequently used to evaluate the ... vaginal ( transvaginal / endovaginal ) for women rectal ( transrectal ) for men A Doppler ultrasound exam may be part of ...

  4. 46 CFR 115.660 - Continued participation in the Alternative Hull Examination (AHE) Program.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 4 2010-10-01 2010-10-01 false Continued participation in the Alternative Hull... MORE THAN 49 PASSENGERS INSPECTION AND CERTIFICATION Hull and Tailshaft Examinations § 115.660 Continued participation in the Alternative Hull Examination (AHE) Program. (a) To continue to participate in...

  5. 46 CFR 176.660 - Continued participation in the Alternative Hull Examination (AHE) Program.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 7 2010-10-01 2010-10-01 false Continued participation in the Alternative Hull... (CONTINUED) SMALL PASSENGER VESSELS (UNDER 100 GROSS TONS) INSPECTION AND CERTIFICATION Hull and Tailshaft Examinations § 176.660 Continued participation in the Alternative Hull Examination (AHE) Program. (a) To...

  6. Examining the Influence of Campus Leadership Programs at a Catholic University

    Science.gov (United States)

    Whitney, Rich; Meents-DeCaigny, Ellen

    2014-01-01

    This study uses the socially responsible leadership and leadership efficacy scales in the Multi-Institutional Study of Leadership (MSL) to examine leadership programs at one Catholic campus, and their influence on socially responsible leadership and leadership efficacy. Examining students that identified as involved in 14 campus leadership…

  7. Unique programming: an examination of the benefits of a free choice program

    Science.gov (United States)

    Dorothy L. Schmalz; Deborah L. Kerstetter; Harry C. Zinn

    2002-01-01

    This study was an investigation of a free choice program and the benefits free choice yields on the developing characteristics of self-esteem and intrinsic motivation among adolescent girls. Both quantitative and qualitative data were collected at Brown Ledge Camp, an all girls summer camp outside of Burlington, Vermont, during the summer of 2000. Quantitative results...

  8. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... transducer sends out high-frequency sound waves (that the human ear cannot hear) into the body and then ... ultrasound , there are no known harmful effects on humans. top of page What are the limitations of Pelvic Ultrasound Imaging? Ultrasound waves are ...

  9. Examining the effectiveness of a restorative justice program for various types of juvenile offenders.

    Science.gov (United States)

    Bergseth, Kathleen J; Bouffard, Jeffrey A

    2013-09-01

    Restorative justice (RJ) programs have become widespread in the United States and in other countries. These programs are often seen as a viable alternative to traditional retributive processing, especially for minor, and sometimes more serious, forms of delinquency and adult criminality. The programs hold promise for achieving several goals, including increased community and victim involvement, greater satisfaction with the case outcomes, improved offender compliance, increased perceptions of fairness, and even recidivism reduction. Meta-analyses have demonstrated varying degrees of program success in recidivism reduction, which may in part reflect differential effectiveness of the RJ approach for various kinds of offenders. This study examined whether an RJ program for juvenile offenders had differential impacts on recidivism across various offender characteristics (including age, gender, racial group, offending history, and current offense). Results generally support the effectiveness of the program for many types of offenders. Implications for future research and potential improvements to the RJ model are discussed.

  10. Examining Variations in Fourth-Grade Children's Participation in School Breakfast and Lunch Programs by Student and Program Demographics

    Science.gov (United States)

    Guinn, Caroline H.; Baxter, Suzanne Domel; Finney, Christopher J.; Hitchcock, David B.

    2013-01-01

    Purpose/Objectives: Analyses were conducted to examine variations in fourth-grade children's participation in school-breakfast and school-lunch programs by weekday, month, socioeconomic status, absenteeism, gender, and school-breakfast location. Methods: Fourth-grade children were participants in a dietary-reporting validation study during either…

  11. Modeling transducer impulse responses for predicting calibrated pressure pulses with the ultrasound simulation program Field II

    DEFF Research Database (Denmark)

    Bæk, David; Jensen, Jørgen Arendt; Willatzen, Morten

    2010-01-01

    FIELD II is a simulation software capable of predicting the field pressure in front of transducers having any complicated geometry. A calibrated prediction with this program is, however, dependent on an exact voltage-to-surface acceleration impulse response of the transducer. Such impulse response...... is not calculated by FIELD II. This work investigates the usability of combining a one-dimensional multilayer transducer modeling principle with the FIELD II software. Multilayer here refers to a transducer composed of several material layers. Measurements of pressure and current from Pz27 piezoceramic disks...... transducer model and the FIELD II software in combination give good agreement with measurements....

  12. Introduction to an open source internet-based testing program for medical student examinations.

    Science.gov (United States)

    Lee, Yoon-Hwan

    2009-12-20

    The author developed a freely available open source internet-based testing program for medical examination. PHP and Java script were used as the programming language and postgreSQL as the database management system on an Apache web server and Linux operating system. The system approach was that a super user inputs the items, each school administrator inputs the examinees' information, and examinees access the system. The examinee's score is displayed immediately after examination with item analysis. The set-up of the system beginning with installation is described. This may help medical professors to easily adopt an internet-based testing system for medical education.

  13. Introduction to an Open Source Internet-Based Testing Program for Medical Student Examinations

    Directory of Open Access Journals (Sweden)

    Yoon-Hwan Lee

    2009-12-01

    Full Text Available The author developed a freely available open source internet-based testing program for medical examination. PHP and Java script were used as the programming language and postgreSQL as the database management system on an Apache web server and Linux operating system. The system approach was that a super user inputs the items, each school administrator inputs the examinees’ information, and examinees access the system. The examinee’s score is displayed immediately after examination with item analysis. The set-up of the system beginning with installation is described. This may help medical professors to easily adopt an internet-based testing system for medical education.

  14. Additional Effect of Static Ultrasound and Diadynamic Currents on Myofascial Trigger Points in a Manual Therapy Program for Patients With Chronic Neck Pain: A Randomized Clinical Trial.

    Science.gov (United States)

    Dibai-Filho, Almir Vieira; de Oliveira, Alessandra Kelly; Girasol, Carlos Eduardo; Dias, Fabiana Rodrigues Cancio; Guirro, Rinaldo Roberto de Jesus

    2017-04-01

    To assess the additional effect of static ultrasound and diadynamic currents on myofascial trigger points in a manual therapy program to treat individuals with chronic neck pain. A single-blind randomized trial was conducted. Both men and women, between ages 18 and 45, with chronic neck pain and active myofascial trigger points in the upper trapezius were included in the study. Subjects were assigned to 3 different groups: group 1 (n = 20) was treated with manual therapy; group 2 (n = 20) was treated with manual therapy and static ultrasound; group 3 (n = 20) was treated with manual therapy and diadynamic currents. Individuals were assessed before the first treatment session, 48 hours after the first treatment session, 48 hours after the tenth treatment session, and 4 weeks after the last session. There was no group-versus-time interaction for Numeric Rating Scale, Neck Disability Index, Pain-Related Self-Statement Scale, pressure pain threshold, cervical range of motion, and skin temperature (F-value range, 0.089-1.961; P-value range, 0.106-0.977). Moreover, we found no differences between groups regarding electromyographic activity (P > 0.05). The use of static ultrasound or diadynamic currents on myofascial trigger points in upper trapezius associated with a manual therapy program did not generate greater benefits than manual therapy alone.

  15. Examining the Feasibility and Effectiveness of a Community-Based Obesity Prevention Program

    Science.gov (United States)

    Cotter, Elizabeth W.; Bera, Victoria; Elsemore, Johanna; Snelling, Anastasia

    2018-01-01

    Background: Latinos in the United States are at heightened risk for obesity and health disparities, yet community-based interventions to promote health are limited. Purpose: This research examined the feasibility and efficacy of a culturally relevant obesity prevention program (Vivir Sano), which included stress reduction and behavioral lifestyle…

  16. A Critical Examination of the Process of Modifying the Curriculum of Alternative Secondary Educational Programs

    Science.gov (United States)

    Ross, Michael

    2014-01-01

    This study, "A Critical Examination of the Process of Modifying the Curriculum of Alternative Secondary Educational Programs," was done with the use of action research to study (a) whether students currently participating in a continuation school believe their educational and career needs are presently being met; (b) the types of career…

  17. Assessment of Primary Representational Systems with Neurolinguistic Programming: Examination of Preliminary Literature.

    Science.gov (United States)

    Dorn, Fred J.; And Others

    1983-01-01

    Reviews the inconsistent findings of studies on neurolinguistic programing and recommends some areas that should be examined to verify various claims. Discusses methods of assessing client's primary representational systems, including predicate usage and eye movements, and suggests that more reliable methods of assessing PRS must be found. (JAC)

  18. A Formalized Three-Year Emergency Medicine Residency Ultrasound Education Curriculum

    Directory of Open Access Journals (Sweden)

    Andrew King

    2016-09-01

    Full Text Available Audience and type of curriculum: The Ohio State University Wexner Medical Center Emergency Medicine Residency Program Ultrasound Education Curriculum is a three-year curriculum for PGY-1 to PGY-3 learners. Introduction/Background: Each year of the three-year The Ohio State University Wexner Medical Center Emergency Medicine Ultrasound Curriculum focuses on different aspects of emergency ultrasonography, thereby promoting progressive understanding and utilization of point-of-care ultrasound in medical decision-making during residency training. Ultrasound is an invaluable bedside tool for emergency physicians; this skill must be mastered by resident learners during residency training, and ultrasound competency is a required ACGME milestone.1 The American College of Emergency Physicians (ACEP currently recommends that 11 applications of emergency ultrasound be part of the core skills of an emergency physician.2 This curriculum acknowledges the standards developed by ACEP and the ACGME. Objectives: Learners will 1 know the indications for each the 11 ACEP point-of-care ultrasound (POCUS applications; 2 perform each of the 11 ACEP POCUS applications; 3 integrate POCUS into medical decision-making. Methods: The educational strategies used in this curriculum include: independent, self-directed learning (textbook and literature reading, brief didactic sessions describing indications and technique for each examination, hands-on ultrasound scanning under the direct supervision of ultrasound faculty with real-time feedback, and quality assurance review of ultrasound images. Residents are expected to perform a minimum of 150 ultrasound examinations with associated quality assurance during the course of their residency training. The time requirements, reading material, and ultrasound techniques taught vary depending on the year of training. Length of curriculum: The entirety of the curriculum is three years; however, each year of residency training has

  19. 46 CFR 176.620 - Description of the Alternative Hull Examination (AHE) Program for certain passenger vessels.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 7 2010-10-01 2010-10-01 false Description of the Alternative Hull Examination (AHE... Hull and Tailshaft Examinations § 176.620 Description of the Alternative Hull Examination (AHE) Program for certain passenger vessels. The Alternative Hull Examination (AHE) Program provides you with an...

  20. 46 CFR 71.50-15 - Description of the Alternative Hull Examination (AHE) Program for certain passenger vessels.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 3 2010-10-01 2010-10-01 false Description of the Alternative Hull Examination (AHE... Description of the Alternative Hull Examination (AHE) Program for certain passenger vessels. The Alternative Hull Examination (AHE) Program provides you with an alternative to a drydock examination by allowing...

  1. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... internal organs, as well as blood flowing through blood vessels. Ultrasound imaging is a noninvasive medical test that helps physicians diagnose and treat medical conditions. ...

  2. Musculoskeletal ultrasound in rheumatology in Korea: targeted ultrasound initiative survey.

    Science.gov (United States)

    Kang, Taeyoung; Wakefield, Richard J; Emery, Paul

    2016-04-01

    In collaboration with the Targeted Ultrasound Initiative (TUI), to conduct the first study in Korea to investigate current practices in ultrasound use among Korean rheumatologists. We translated the TUI Global Survey into Korean and added questions to better understand the specific challenges facing rheumatologists in Korea. To target as many rheumatologists in Korea as possible, we created an on-line version of this survey, which was conducted from March to April 2013. Rheumatologists are in charge of ultrasound in many Korean hospitals. Rheumatologists in hospitals and private clinics use ultrasound to examine between one and five patients daily; they use ultrasound for diagnosis more than monitoring and receive compensation of about US$30-50 per patient. There are marked differences in the rates of ultrasound usage between rheumatologists who work in private practice compared with tertiary hospitals. Korean rheumatologists not currently using ultrasound in their practice appear eager to do so. This survey provides important insights into the current status of ultrasound in rheumatology in Korea and highlights several priorities; specifically, greater provision of formal training, standardization of reporting and accrual of greater experience among ultrasound users. If these needs are addressed, all rheumatology departments in Korea are likely to use ultrasound or have access to it in the future. © 2014 Asia Pacific League of Associations for Rheumatology and Wiley Publishing Asia Pty Ltd.

  3. Ultrasound diagnostics of thyroid diseases

    International Nuclear Information System (INIS)

    Kharchenko, Vladimir P.; Kotlyarov, Peter M.; Mogutov, Mikhail S.; Sencha, Alexander N.; Patrunov, Yury N.; Belyaev, Denis V.; Alexandrov, Yury K.

    2010-01-01

    This book is based on the authors' extensive practical experience in the use of modern ultrasound, and other radiological methods, in the diagnosis of thyroid diseases. The authors have analyzed more than 100,000 ultrasound examinations performed between 1995 and 2008 in patients with thyroid and parathyroid disease, as well as many thousands of diagnostic and therapeutic ultrasound-guided minimally invasive procedures. The opening chapters include discussion of current ultrasound techniques, pitfalls, and the specifics of ultrasound examination of the thyroid in children. Detailed attention is then devoted to findings in the normal thyroid and in the presence of diffuse and focal changes. Further chapters focus on such topics as ultrasound examination after thyroid surgery and ultrasound diagnosis of parathyroid disease, recurrent goiter, and neck masses. Ultrasound-guided minimally invasive techniques, such as fine-needle aspiration biopsy, percutaneous laser ablation, and ethanol and glucocorticoid injections, are considered in depth. This up-to-date and richly illustrated book will interest and assist specialists in ultrasound diagnostics, radiologists, endocrinologists, and neck surgeons. (orig.)

  4. Children's (Pediatric) Abdominal Ultrasound Imaging

    Medline Plus

    Full Text Available ... children. Preparation will depend on the type of examination. Ask your doctor if there are specific instructions ... those sound waves to create an image. Ultrasound examinations do not use ionizing radiation (as used in ...

  5. Children's (Pediatric) Abdominal Ultrasound Imaging

    Medline Plus

    Full Text Available ... most ultrasound exams, you will be positioned lying face-up on an examination table that can be ... in a known abnormality can be monitored over time. Follow-up examinations are sometimes the best way ...

  6. Examination of program exposure across intervention delivery modes: face-to-face versus internet

    Directory of Open Access Journals (Sweden)

    Mummery W Kerry

    2007-03-01

    Full Text Available Abstract Background There has been increasing interest in the ability of the internet to produce behaviour change. The focus of this study was to describe program exposure across three intervention groups from a randomised trial (RT comparing traditional face-to-face, internet-mediated (combined internet plus face-to-face, and internet-only program delivery. Methods Baseline and immediately post-intervention survey data, and exposure rates from participants that commenced the RT were included (n = 192. Exposure was defined as either face-to-face attendance, website usage, or a combination of both for the internet-mediated group. Characteristics of participants who were exposed to at least 75% of the program material were explored. Descriptive analysis and logistical regression were used to examine differences between groups for program exposure. Results All groups showed decrease in program exposure over time. Differences were also observed (χ2 = 10.37, p Conclusion These results suggest that the internet groups were as effective as the face-to-face delivery mode in engaging participants in the program material. However, different delivery methods may be more useful to different sub-populations. It is important to explore which target groups that internet-based programs are best suited, in order to increase their impact.

  7. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... inserted into a man's rectum to view the prostate. Transvaginal ultrasound. The transducer is inserted into a ... Stenting Ultrasound-Guided Breast Biopsy Obstetric Ultrasound Ultrasound - Prostate Biopsies - Overview Images related to General Ultrasound Videos ...

  8. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... News Physician Resources Professions Site Index A-Z General Ultrasound Ultrasound imaging uses sound waves to produce ... the limitations of General Ultrasound Imaging? What is General Ultrasound Imaging? Ultrasound is safe and painless, and ...

  9. Attributes of Candidates Passing the ABS Certifying Examination on the First Attempt-Program Directors׳ Perspective.

    Science.gov (United States)

    Sheikh, Mohd Raashid; Hulme, Michael

    2016-01-01

    The American Board of Surgery Certifying Examination (CE) is a pivotal event in a surgeon's career development, as it is the last challenge before achieving Board certification. First-time pass rate on the CE is one of the key metrics of surgery residency programs. The overall pass rate on the CE has declined significantly in recent years. The goal of this study was the identification of attributes of general surgery residents that are associated with passing the CE at the first attempt. The modified Delphi process was used to survey general surgery program directors. The study was conducted in 2 rounds in the interest of time available for surgical education research fellowship project. All 259 program directors were contacted in each round of surveys. In all, 49 (19%) responded to the first round and 54 (21%) responded to the second round of survey. The characteristics of a successful resident on CE include confidence, self-motivation, sound knowledge base, strong performance on the Board's training examination (American Board of Surgery In-Training Examination), and mock orals, and good communication skills. Postgraduate years 4 and 5 are the most likely resident levels at which failure could be predicted. Copyright © 2015 Association of Program Directors in Surgery. Published by Elsevier Inc. All rights reserved.

  10. Implementing the objective structured clinical examination in a geriatrics fellowship program-a 3-year experience.

    Science.gov (United States)

    Avelino-Silva, Thiago J; Gil, Luiz A; Suemoto, Claudia K; Kikuchi, Elina L; Lin, Sumika M; Farias, Luciana L; Jacob-Filho, Wilson

    2012-07-01

    The Objective Structured Clinical Examination (OSCE) appears to be an effective alternative for assessing not only medical knowledge, but also clinical skills, including effective communication and physical examination skills. The purpose of the current study was to implement an OSCE model in a geriatrics fellowship program and to compare the instrument with traditional essay examination. Seventy first- and second-year geriatric fellows were initially submitted to a traditional essay examination and scored from 0 to 10 by a faculty member. The same fellows subsequently underwent an OSCE with eight 10-minute stations covering a wide range of essential aspects of geriatric knowledge. Each OSCE station had an examiner responsible for its evaluation according to a predefined checklist. Checklist items were classified for analysis purposes as clinical knowledge items (CKI) and communication skills items (CSI); fellow responses were scored from 0 to 10.Although essay examinations took from 30 to 45 minutes to complete, 180-200 minutes were required to evaluate fellows using the proposed OSCE method. Fellows scored an average of 6.2 ± 1.2 on the traditional essay examination and 6.6 ± 1.0 on the OSCE (P examination was similar to their performance on CKI (P = .13). Second-year fellows performed better than first-year fellows on the essay examination (P geriatrics fellowship program. Combining different testing modalities may provide the best assessment of competence for various domains of knowledge, skills, and behavior. © 2012, Copyright the Authors Journal compilation © 2012, The American Geriatrics Society.

  11. Prostate Ultrasound

    Medline Plus

    Full Text Available ... be able to give a clearer picture of soft tissues that do not show up well on x-ray images. Ultrasound causes no health problems and may be repeated as often as is necessary if medically indicated. Ultrasound provides real-time imaging, making it a good tool for guiding ...

  12. Prostate Ultrasound

    Science.gov (United States)

    ... be able to give a clearer picture of soft tissues that do not show up well on x-ray images. Ultrasound causes no health problems and may be repeated as often as is necessary if medically indicated. Ultrasound provides real-time imaging, making it a good tool for guiding ...

  13. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available Toggle navigation Test/Treatment Patient Type Screening/Wellness Disease/Condition Safety En Español More Info Images/Videos About Us News Physician Resources Professions Site Index A-Z Ultrasound - Pelvis Ultrasound imaging of the pelvis uses sound waves to ...

  14. Interventional ultrasound

    International Nuclear Information System (INIS)

    VanSonnenberg, E.

    1987-01-01

    This book contains 12 chapters and several case studies. Some of the chapter titles are: The Interplay of Ultrasound and Computed Tomography in the Planning and Execution of Interventional Procedures: Ulltrasound Guided Biopsy; Interventioal Genitourinary Sonography; Diagnosis and Treatment of Pericardial Effusion Using Ultrasonic Guidance; and New Ultrasound-Guided Interventional Procedures--Cholecystostomy, Pancreatography, Gastrostomy

  15. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available Toggle navigation Test/Treatment Patient Type Screening/Wellness Disease/Condition Safety En Español More Info Images/Videos About Us News Physician Resources Professions Site Index A-Z Ultrasound - Pelvis Ultrasound imaging ...

  16. Prostate Ultrasound

    Medline Plus

    Full Text Available Toggle navigation Test/Treatment Patient Type Screening/Wellness Disease/Condition Safety En Español More Info Images/Videos About Us News Physician Resources Professions Site Index A-Z Ultrasound - Prostate Ultrasound of ...

  17. Ultrasound stethoscopy

    NARCIS (Netherlands)

    E.C. Vourvouri (Eleni)

    2002-01-01

    textabstractIn this thesis we repmi the many evaluation studies with the hand-held ultrasound device in the assessment of different cardiac pathologies and in different clinical settings. The reason for using the tetm "ultrasound stethoscopy" is that these devices are augmenting our

  18. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... to-use and less expensive than other imaging methods. Ultrasound imaging is extremely safe and does not use any ionizing radiation. Ultrasound scanning gives a clear picture of soft tissues that do not show up well on ...

  19. Prostate Ultrasound

    Medline Plus

    Full Text Available ... the best way to see if treatment is working or if a finding is stable or changed over time. top of page What are the benefits vs. risks? Benefits Ultrasound is widely available, easy-to-use and less expensive than other imaging methods. Ultrasound imaging uses ...

  20. Prostate Ultrasound

    Medline Plus

    Full Text Available ... the patient. Because ultrasound images are captured in real-time, they can show the structure and movement of ... blood test result. difficulty urinating. Because ultrasound provides real-time images, it also can be used to guide ...

  1. Long-Term Prognosis of Plantar Fasciitis: A 5- to 15-Year Follow-up Study of 174 Patients With Ultrasound Examination

    Science.gov (United States)

    Hansen, Liselotte; Krogh, Thøger Persson; Ellingsen, Torkell; Bolvig, Lars; Fredberg, Ulrich

    2018-01-01

    Background: Plantar fasciitis (PF) affects 7% to 10% of the population. The long-term prognosis is unknown. Purpose: Our study had 4 aims: (1) to assess the long-term prognosis of PF, (2) to evaluate whether baseline characteristics (sex, body mass index, age, smoking status, physical work, exercise-induced symptoms, bilateral heel pain, fascia thickness, and presence of a heel spur) could predict long-term outcomes, (3) to assess the long-term ultrasound (US) development in the fascia, and (4) to assess whether US-guided corticosteroid injections induce atrophy of the heel fat pad. Study Design: Cohort study; Level of evidence, 3. Methods: From 2001 to 2011 (baseline), 269 patients were diagnosed with PF based on symptoms and US. At follow-up (2016), all patients were invited to an interview regarding their medical history and for clinical and US re-examinations. Kaplan-Meier survival estimates were used to estimate the long-term prognosis, and a multiple Cox regression analysis was used for the prediction model. Results: In all, 174 patients (91 women, 83 men) participated in the study. All were interviewed, and 137 underwent a US examination. The mean follow-up was 9.7 years from the onset of symptoms and 8.9 years from baseline. At follow-up, 54% of patients were asymptomatic (mean duration of symptoms, 725 days), and 46% still had symptoms. The risk of having PF was 80.5% after 1 year, 50.0% after 5 years, 45.6% after 10 years, and 44.0% after 15 years from the onset of symptoms. The risk was significantly greater for women (P Fascia thickness decreased significantly in both the asymptomatic and symptomatic groups (P Fascia thickness (P = .49) and presence of a heel spur (P = .88) at baseline had no impact on prognosis. At follow-up, fascia thickness and echogenicity had normalized in only 24% of the asymptomatic group. The mean fat pad thickness was 9.0 mm in patients who had received a US-guided corticosteroid injection and 9.4 mm in those who had not been

  2. Feasibility of Remote Real-Time Guidance of a Cardiac Examination Performed by Novices Using a Pocket-Sized Ultrasound Device

    Directory of Open Access Journals (Sweden)

    Tuan V. Mai

    2013-01-01

    Full Text Available Background. The potential of pocket-sized ultrasound devices (PUDs to improve global healthcare delivery is limited by the lack of a suitable imaging protocol and trained users. Therefore, we investigated the feasibility of performing a brief, evidence-based cardiac limited ultrasound exam (CLUE through wireless guidance of novice users. Methods. Three trainees applied PUDs on 27 subjects while directed by an off-site cardiologist to obtain a CLUE to screen for LV systolic dysfunction (LVSD, LA enlargement (LAE, ultrasound lung comets (ULC+, and elevated CVP (eCVP. Real-time remote audiovisual guidance and interpretation by the cardiologist were performed using the iPhone 4/iPod (FaceTime, Apple, Inc. attached to the PUD and transmitted data wirelessly. Accuracy and technical quality of transmitted images were compared to on-site, gold-standard echo thresholds. Results. Novice versus sonographer imaging yielded technically adequate views in 122/135 (90% versus 130/135 (96% (. CLUE’s combined SN, SP, and ACC were 0.67, 0.96, and 0.90. Technical adequacy (% and accuracy for each abnormality ( were LVSD (85%, 0.93, , LAE (89%, 0.74, , ULC+ (100%, 0.94, , and eCVP (78%, 0.91, . Conclusion. A novice can perform the CLUE using PUD when wirelessly guided by an expert. This method could facilitate PUD use for off-site bedside medical decision making and triaging of patients.

  3. Reliability of mechanical and phased-array designs for serial intravascular ultrasound examinations--animal and clinical studies in stented and non-stented coronary arteries.

    Science.gov (United States)

    Tardif, J C; Bertrand, O F; Mongrain, R; Lespérance, J; Grégoire, J; Paiement, P; Bonan, R

    2000-10-01

    Both mechanical and multi-element intravascular ultrasound designs have potential advantages and limitations that may impact on their value for clinical and research purposes. Determination of the reproducibility of measurements is critical before a given system can be used in studies such as regression of atherosclerosis trials. We performed serial intravascular ultrasound imaging with catheters using mechanical and phased-array designs in stented and non-stented coronary arteries in dogs and in patients. Both systems correlated well for areas (r > or = 0.90, p or = 0.84. p mechanical designs for measurements of area (mean difference in dogs and in patients: -0.24 and 0.96 mm2, p mechanical system (r > or = 0.96 for all measurements). The differences in absolute and relative variability between the mechanical and phased-array designs, both for reanalysis of same frames and serial pullbacks, were very small. Although multi-element and mechanical intravascular ultrasound designs are not strictly interchangeable, their similar reproducibility and the small differences in measurements demonstrate that both designs are acceptable alternatives for trials of regression of atherosclerosis. Determination of the variability for serial pullbacks of both designs was also important to assess the statistical power of such trials.

  4. Undergraduate grade point average and graduate record examination scores: the experience of one graduate nursing program.

    Science.gov (United States)

    Newton, Sarah E; Moore, Gary

    2007-01-01

    Graduate nursing programs frequently use undergraduate grade point average (UGPA) and Graduate Record Examination (GRE) scores for admission decisions. The literature indicates that both UGPA and GRE scores are predictive of graduate school success, but that UGPA may be the better predictor. If that is so, one must ask if both are necessary for graduate nursing admission decisions. This article presents research on one graduate nursing program's experience with UGPA and GRE scores and offers a perspective regarding their continued usefulness for graduate admission decisions. Data from 120 graduate students were examined, and regression analysis indicated that UGPA significantly predicted GRE verbal and quantitative scores (p < .05). Regression analysis also determined a UGPA score above which the GRE provided little additional useful data for graduate nursing admission decisions.

  5. Children's (Pediatric) Abdominal Ultrasound Imaging

    Medline Plus

    Full Text Available ... within your child’s abdomen. Ultrasound does not use ionizing radiation, has no known harmful effects, and is particularly ... create an image. Ultrasound examinations do not use ionizing radiation (as used in x-rays ), thus there is ...

  6. An Approach to Examining the Proximal and Intermediate Outcomes of an Intensive Family Preservation Program

    Science.gov (United States)

    Hurley, Kristin Duppong; Griffith, Annette; Ingram, Stephanie; Bolivar, Claudine; Mason, W. Alex; Trout, Alexandra

    2012-01-01

    This study examined the effects of the Boys Town In-Home Family Program (BT-IHFP) on parenting skills, family functioning, and child behavior for at-risk families involved with child protective services. The BT-IHFP is designed as a home-based, family-centered alternative to out-of-home placement with the goal of improving family functioning,…

  7. United States Medical Licensing Examination and American Board of Pediatrics Certification Examination Results: Does the Residency Program Contribute to Trainee Achievement.

    Science.gov (United States)

    Welch, Thomas R; Olson, Brad G; Nelsen, Elizabeth; Beck Dallaghan, Gary L; Kennedy, Gloria A; Botash, Ann

    2017-09-01

    To determine whether training site or prior examinee performance on the US Medical Licensing Examination (USMLE) step 1 and step 2 might predict pass rates on the American Board of Pediatrics (ABP) certifying examination. Data from graduates of pediatric residency programs completing the ABP certifying examination between 2009 and 2013 were obtained. For each, results of the initial ABP certifying examination were obtained, as well as results on National Board of Medical Examiners (NBME) step 1 and step 2 examinations. Hierarchical linear modeling was used to nest first-time ABP results within training programs to isolate program contribution to ABP results while controlling for USMLE step 1 and step 2 scores. Stepwise linear regression was then used to determine which of these examinations was a better predictor of ABP results. A total of 1110 graduates of 15 programs had complete testing results and were subject to analysis. Mean ABP scores for these programs ranged from 186.13 to 214.32. The hierarchical linear model suggested that the interaction of step 1 and 2 scores predicted ABP performance (F[1,1007.70] = 6.44, P = .011). By conducting a multilevel model by training program, both USMLE step examinations predicted first-time ABP results (b = .002, t = 2.54, P = .011). Linear regression analyses indicated that step 2 results were a better predictor of ABP performance than step 1 or a combination of the two USMLE scores. Performance on the USMLE examinations, especially step 2, predicts performance on the ABP certifying examination. The contribution of training site to ABP performance was statistically significant, though contributed modestly to the effect compared with prior USMLE scores. Copyright © 2017 Elsevier Inc. All rights reserved.

  8. Examining Sense of Community among Medical Professionals in an Online Graduate Program

    Directory of Open Access Journals (Sweden)

    Kadriye O. Lewis

    2015-01-01

    Full Text Available As the number of online degree programs continues to grow, one of the greatest challenges is developing a sense of community among learners who do not convene at the same time and place. This study examined the sense of community among medical professionals in an online graduate program for healthcare professionals. We took the sample from a fully online program delivered jointly by a state university and a local children's hospital in the Midwest. We administered Rovai's Classroom Community Survey with 11 additional demographic questions. We also utilized online interviews to further explore students’ understanding of sense of community. A bi-factor model was fitted to the online sense of community survey data. Using multivariate analysis of variance (MANOVA and univariate analysis of variance (ANOVA we identified potential group differences. The qualitative data were analyzed thematically in a recursive and iterative process. Study results suggested that a dominant factor existed: sense of community with two sub-domain factors including sense of learning and sense of connectedness. No significant differences in sense of community with regard to gender, native language, or area of medical practice were detected. However, results showed a difference in sense of community between the three courses examined. This study is the first to examine the sense of community among online medical professionals. Since our findings are in contrast to those of previous studies, this opens the door to additional studies around the possible differences between the community characteristics and needs of medical professionals as online students.

  9. Evaluation of a training program for general ultrasound screening for developmental dysplasia of the hip in preventive child health care

    NARCIS (Netherlands)

    Boere-Boonekamp, Magdalena M.; Ramwadhdoebe, S.; Sakkers, R.J.B.; Uiterwaal, Cuno S.P.M.; Beek, Frederik J.A.

    2010-01-01

    Background: A research study in the Netherlands showed that general ultrasound (US) screening was cost-effective in the detection of developmental dysplasia of the hip (DDH). This study was followed by a pilot implementation study. Part of this pilot implementation study is to investigate whether

  10. An Examination of Peer-Delivered Parenting Skills Programs Across New York State.

    Science.gov (United States)

    Acri, Mary C; Craig, Nancy; Adler, Josh

    2018-03-24

    Peers are an important adjunct to the public mental health service system, and are being increasingly utilized across the country as a cost-effective solution to workforce shortages. Despite the tremendous growth of peer-delivered support over the past two decades, it has only been within the past few years that peer programs have been the subject of empirical inquiry. The purpose of this study was to examine the prevalence and characteristics of peer-delivered parenting programs across the New York State public mental health service system. We surveyed 46 family peer organizations across New York State regarding their delivery of structured peer-delivered parenting programs. Thirty-four (76%) completed the questionnaire, and of them, 18 (53%) delivered a parenting program. Subsequent interviews with seven of the 18 organizations revealed peer organizations had been delivering eight unique parenting programs for upwards of two decades. Additionally, organizations offered multiple supports to families to participate. Training, supervision, and issues around fidelity are discussed, as well as the implications of this study for states utilizing a peer workforce.

  11. A STUDY OF THE REQUIRED PUBLIC ACCOUNTING PROGRAM IN PUBLIC COMPETITIVE EXAMINATIONS HELD BY CESPE

    Directory of Open Access Journals (Sweden)

    Fátima de Souza Freire

    2012-11-01

    Full Text Available With a view to standardizing the contents offered to future Accounting professionals, the Federal Accounting Council (CFC elaborated the National Proposal for Undergraduate Accountancy Program Contents. Thus, the curriculum that Higher Education Institutions (HEI adopt serves as an ally for students’ professional conquests. Stability and favorable job conditions attract many people to the dispute for a public function, with a growing Braz ilian public competitive examination market. According to the National Association for Protection and Support to Public Competitive Examinations (Anpac, between 2003 and 2009, the number of public servants in the executive power with a higher education degree in Brazil increased by 26%. The aim of this study was to confront the CFC’s suggested knowledge with the contents required during tests applied in public competitive examinations for Accountancy professionals. The intent is to identify what Public Accounting knowledge is demanded from candidates for the public career. Through a documentary research, 561 calls from public competitive examinations exclusively for Accountancy professionals were selected for the study sample. They were classified according to the proposed program contents, the test questions by the Center for Selection and Event Promotion (Cespe, between 2000 and 2009. In conclusion, the most frequent required Public Accounting areas are contents related to Public Equity and Budget. The results demonstrate that the CFC’s suggested content is in line with the knowledge required from candidates for public functions.

  12. Reference Ranges of Amniotic Fluid Index in Late Third Trimester of Pregnancy: What Should the Optimal Interval between Two Ultrasound Examinations Be?

    Directory of Open Access Journals (Sweden)

    Shripad Hebbar

    2015-01-01

    to examine the magnitude of change at different time intervals. Results. Starting from 34 weeks till 40 weeks, 50 ultrasound measurements were available at each gestational age. The mean (standard deviation of AFI values (in cms were 34 W: 14.59 (1.79, 35 W: 14.25 (1.57, 36 W: 13.17 (1.56, 37 W: 12.48 (1.52, 38 W: 12.2 (1.7, and 39 W: 11.37 (1.71. The 5th percentile cut-off was 8.7 cm at 40 weeks. There was a gradual decline of AFI values as the gestational age approached term. Significant drop in AFI was noted at two-week intervals. AFI curve generated from the study varied significantly when compared with already published data, both from India and abroad. Conclusion. Normative range for AFI values for late third trimester was established. Appreciable changes occurred in AFI values as gestation advanced by two weeks. Hence, it is recommended to follow up low risk antenatal women every two weeks after 34 weeks of pregnancy. The percentile curves of AFI obtained from the present study may be used to detect abnormalities of amniotic fluid for our population.

  13. A simple program to reduce the stress associated with NRC nuclear operator examinations

    International Nuclear Information System (INIS)

    Sajwau, T.; Chardos, S.

    1988-01-01

    The NRC license for nuclear reactor operators requires periodic written examinations to demonstrate ongoing technical competency. Poor performance raises a competency question and can affect the individuals' careers. Accordingly, the exams can be highly stressful events. Stress has been demonstrated to affect memory, perception, other cognitive attitudes, and test performance. The phenomenon of test anxiety is well known. Instead of a generic, broadly focused stress management approach, a sharply focused, two-part program was developed for TVA operators scheduled to take the NRC examination. The first part was presented early in preparatory training, and the second part was given just prior to the examination. The first part consisted of a simple model of stress found in exams, early warning signs of test stress, and tactics of stress management that were practical to use during the NRC exam itself

  14. The refinement of a cultural standardized patient examination for a general surgery residency program.

    Science.gov (United States)

    Chun, Maria B J; Deptula, Peter; Morihara, Sarah; Jackson, David S

    2014-01-01

    Recent articles have documented the importance of cultural competency in surgery. Surgical residency programs have used the Objective Structured Clinical Examinations or cultural standardized patient examinations as a training tool. Past studies evaluating cultural competency have noted the importance of including an observational (control) arm, which would allow for a more objective assessment of a resident's competency in this area. The purpose of our article is to present the results of a follow-up study to a pilot cultural standardized patient examination for surgery residents. All first-year surgery residents were required to participate in the videotaped cultural SP examination as part of the general surgery residency curriculum. Two measures were used to assess resident performance. On the day of the examination, the Cross-Cultural Care Survey was administered. The examination was assessed by the residents themselves, faculty observers, and standardized patients, using a written checklist that was developed to evaluate residents on all 6 Accreditation Council for Graduate Medical Education competencies. The current study includes 20 first-year surgery residents from academic years 2011 to 2012 and 2012 to 2013. The examination of pretest differences in groups found that students born outside of the United States had significantly higher scores on attitude (t = -2.68, df = 18, p = 0.02), but no statistically significant differences were found in skillfulness or knowledge or in the overall rating scale. For the overall rating scale, change from pretest to posttest was statistically significant (t = -2.25, df = 18, p = 0.04). Further analysis revealed that students who were born in the United States demonstrated a significant increase in ratings (t = -3.08, df = 10, p = 0.01) whereas students who were not born in the United States showed little change (t = -0.35, df = 7, p = 0.74). These results show that the means in attitude scales changed little for all

  15. Physics of Ultrasound. Chapter 12

    Energy Technology Data Exchange (ETDEWEB)

    Lacefield, J. C. [University of Western Ontario, London (Canada)

    2014-09-15

    Ultrasound is the most commonly used diagnostic imaging modality, accounting for approximately 25% of all imaging examinations performed worldwide at the beginning of the 21st century. The success of ultrasound may be attributed to a number of attractive characteristics, including the relatively low cost and portability of an ultrasound scanner, the non-ionizing nature of ultrasound waves, the ability to produce real time images of blood flow and moving structures such as the beating heart, and the intrinsic contrast among soft tissue structures that is achieved without the need for an injected contrast agent. The latter characteristic enables ultrasound to be used for a wide range of medical applications, which historically have primarily included cardiac and vascular imaging, imaging of the abdominal organs and, most famously, in utero imaging of the developing fetus. Ongoing technological improvements continue to expand the use of ultrasound for many applications, including cancer imaging, musculoskeletal imaging, ophthalmology and others. The term ultrasound refers specifically to acoustic waves at frequencies greater than the maximum frequency audible to humans, which is nominally 20 kHz. Diagnostic imaging is generally performed using ultrasound in the frequency range of 2–15 MHz. The choice of frequency is dictated by a trade off between spatial resolution and penetration depth, since higher frequency waves can be focused more tightly but are attenuated more rapidly by tissue. The information contained in an ultrasonic image is influenced by the physical processes underlying propagation, reflection and attenuation of ultrasound waves in tissue.

  16. A Comprehensive Examination of the Influence of State Tobacco Control Programs and Policies on Youth Smoking

    Science.gov (United States)

    Loomis, Brett R.; Han, Beth; Gfroerer, Joe; Kuiper, Nicole; Couzens, G. Lance; Dube, Shanta; Caraballo, Ralph S.

    2013-01-01

    Objectives. We examined the influence of tobacco control policies (tobacco control program expenditures, smoke-free air laws, youth access law compliance, and cigarette prices) on youth smoking outcomes (smoking susceptibility, past-year initiation, current smoking, and established smoking). Methods. We combined data from the 2002 to 2008 National Surveys on Drug Use and Health with state and municipality population data from the US Census Bureau to assess the associations between state tobacco control policy variables and youth smoking outcomes, focusing on youths aged 12 to 17 years. We also examined the influence of policy variables on youth access when these variables were held at 2002 levels. Results. Per capita funding for state tobacco control programs was negatively associated with all 4 smoking outcomes. Smoke-free air laws were negatively associated with all outcomes except past-year initiation, and cigarette prices were associated only with current smoking. We found no association between these outcomes and retailer compliance with youth access laws. Conclusions. Smoke-free air laws and state tobacco control programs are effective strategies for curbing youth smoking. PMID:23327252

  17. Modeling of ultrasound transducers

    DEFF Research Database (Denmark)

    Bæk, David

    This Ph.D. dissertation addresses ultrasound transducer modeling for medical ultrasound imaging and combines the modeling with the ultrasound simulation program Field II. The project firstly presents two new models for spatial impulse responses (SIR)s to a rectangular elevation focused transducer...... (REFT) and to a convex rectangular elevation focused transducer (CREFT). These models are solvable on an analog time scale and give exact smooth solutions to the Rayleigh integral. The REFT model exhibits a root mean square (RMS) error relative to Field II predictions of 0.41 % at 3400 MHz, and 1.......37 % at 100MHz. The CREFT model exhibits a RMS deviation of 0.01 % relative to the exact numerical solution on a CREFT transducer. A convex non-elevation focused, a REFT, and a linear flat transducer are shown to be covered with the CREFT model as well. Pressure pulses calculated with a one...

  18. Examining the Factors Associated with Paid Employment of Clients Enrolled in First Episode of Psychosis Programs

    Directory of Open Access Journals (Sweden)

    Carolyn S. Dewa

    2012-01-01

    Full Text Available Schizophrenia is one of the most debilitating mental disorders. For a significant portion of individuals who suffer from this disorder, onset occurs in young adulthood, arresting important social and educational development that is necessary for future successful labor force participation. The purpose of this paper is to contribute to the literature about clients enrolled in first episode psychosis programs and psychosocial outcomes by examining the factors associated with paid employment among young adults who have experienced their first psychotic episodes. In this paper, we consider the association of socioeconomic factors to employment. Our results suggest that in addition to treatment, socioeconomic factors such as receipt of public disability benefits and educational attainment are associated with employment status. These results can help to inform future directions for the enhancement of psychosocial programs in FEP models to promote paid employment.

  19. Fetal Ultrasound

    Science.gov (United States)

    ... isn't recommended simply to determine a baby's sex. Similarly, fetal ultrasound isn't recommended solely for the purpose of producing keepsake videos or pictures. If your health care provider doesn' ...

  20. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... and movement of the body's internal organs, as well as blood flowing through blood vessels. Ultrasound imaging is a noninvasive medical test that helps physicians diagnose and treat medical conditions. ...

  1. Prostate Ultrasound

    Medline Plus

    Full Text Available ... and movement of the body's internal organs, as well as blood flowing through blood vessels. Ultrasound imaging is a noninvasive medical test that helps physicians diagnose and treat medical conditions. ...

  2. Prostate Ultrasound

    Medline Plus

    Full Text Available ... nodule felt by a physician during a routine physical exam or prostate cancer screening exam. an elevated blood test result. difficulty urinating. Because ultrasound provides real-time ...

  3. Prostate Ultrasound

    Medline Plus

    Full Text Available ... requested the exam. Usually, the referring physician or health care provider will share the results with you. ... well on x-ray images. Ultrasound causes no health problems and may be repeated as often as ...

  4. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... ultrasound exams are also used to monitor the health and development of an embryo or fetus during ... requested the exam. Usually, the referring physician or health care provider will share the results with you. ...

  5. Prostate Ultrasound

    Medline Plus

    Full Text Available ... probe) and ultrasound gel placed directly on the skin. High-frequency sound waves are transmitted from the ... the transducer (the device placed on the patient's skin to send and receive the returning sound waves), ...

  6. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... probe) and ultrasound gel placed directly on the skin. High-frequency sound waves are transmitted from the ... the transducer (the device placed on the patient's skin to send and receive the returning sound waves), ...

  7. Prostate Ultrasound

    Medline Plus

    Full Text Available ... no ionizing radiation. Ultrasound scanning may be able to give a clearer picture of soft tissues that do ... understanding of the possible charges you will incur. Web page review process: This Web page is reviewed ...

  8. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... use different transducers (with different capabilities) during a single exam. The transducer sends out high-frequency sound ... modality for the diagnosis and monitoring of pregnant women and their unborn babies. Ultrasound provides real-time ...

  9. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... collects the sounds that bounce back and a computer then uses those sound waves to create an ... Ultrasound scanners consist of a console containing a computer and electronics, a video display screen and a ...

  10. Prostate Ultrasound

    Medline Plus

    Full Text Available ... collects the sounds that bounce back and a computer then uses those sound waves to create an ... Ultrasound scanners consist of a console containing a computer and electronics, a video display screen and a ...

  11. Prostate Ultrasound

    Medline Plus

    Full Text Available ... sends out high-frequency sound waves (that the human ear cannot hear) into the body and then ... ultrasound , there are no known harmful effects on humans. top of page What are the limitations of ...

  12. Prostate Ultrasound

    Medline Plus

    Full Text Available ... the rectal wall is relatively insensitive to the pain in the region of the prostate. A biopsy ... needle biopsies and fluid aspiration. Risks For standard diagnostic ultrasound , there are no known harmful effects on ...

  13. Prostate Ultrasound

    Medline Plus

    Full Text Available ... diagnose symptoms such as difficulty urinating or an elevated blood test result. It’s also used to investigate ... physical exam or prostate cancer screening exam. an elevated blood test result. difficulty urinating. Because ultrasound provides ...

  14. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... The principles are similar to sonar used by boats and submarines. The ultrasound image is immediately visible ... principles involved in the sonar used by bats, ships and fishermen. When a sound wave strikes an ...

  15. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... areas of the body while other areas, especially air-filled lungs, are poorly suited for ultrasound. For ... make secure contact with the body and eliminate air pockets between the transducer and the skin that ...

  16. Prostate Ultrasound

    Medline Plus

    Full Text Available ... a follow-up exam is done because a potential abnormality needs further evaluation with additional views or ... of soft tissues that do not show up well on x-ray images. Ultrasound causes no health ...

  17. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... a follow-up exam is done because a potential abnormality needs further evaluation with additional views or ... of soft tissues that do not show up well on x-ray images. Ultrasound is the preferred ...

  18. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... is smaller than the standard speculum used when performing a Pap test . A protective cover is placed ... of soft tissues that do not show up well on x-ray images. Ultrasound is the preferred ...

  19. Prostate Ultrasound

    Medline Plus

    Full Text Available ... scanning or sonography , involves the use of a small transducer (probe) and ultrasound gel placed directly on ... to do the scanning. The transducer is a small hand-held device that resembles a microphone, attached ...

  20. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... scanning or sonography , involves the use of a small transducer (probe) and ultrasound gel placed directly on ... the child prior to the exam. Bringing books, small toys, music or games can help to distract ...

  1. Prostate Ultrasound

    Medline Plus

    Full Text Available ... less than 20 minutes. top of page What will I experience during and after the procedure? Ultrasound ... in the region of the prostate. A biopsy will add time to the procedure. Rarely, a small ...

  2. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... ultrasound images are reviewed. top of page What will I experience during and after the procedure? For ... in the region of the prostate. A biopsy will add time to the procedure. If a Doppler ...

  3. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... arteries and veins in the abdomen, arms, legs, neck and/or brain (in infants and children) or ... diagnose symptoms experienced by women such as: pelvic pain abnormal vaginal bleeding other menstrual problems Ultrasound exams ...

  4. Prostate Ultrasound

    Medline Plus

    Full Text Available ... gel. top of page How does the procedure work? Ultrasound imaging is based on the same principles ... the best way to see if treatment is working or if a finding is stable or changed ...

  5. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... and development of an embryo or fetus during pregnancy. See the Obstetrical Ultrasound page for more information . ... move through vessels. The movement of blood cells causes a change in pitch of the reflected sound ...

  6. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... abdomen, arms, legs, neck and/or brain (in infants and children) or within various body organs such ... and monitoring of pregnant women and their unborn babies. Ultrasound provides real-time imaging, making it a ...

  7. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... to-use and less expensive than other imaging methods. Ultrasound imaging is extremely safe and does not ... barium exams, CT scanning , and MRI are the methods of choice in such a setting. Large patients ...

  8. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... insertion. top of page How does the procedure work? Ultrasound imaging is based on the same principles ... move through vessels. The movement of blood cells causes a change in pitch of the reflected sound ...

  9. Prostate Ultrasound

    Medline Plus

    Full Text Available ... gel. top of page How does the procedure work? Ultrasound imaging is based on the same principles ... requested the exam. Usually, the referring physician or health care provider will share the results with you. ...

  10. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... insertion. top of page How does the procedure work? Ultrasound imaging is based on the same principles ... requested the exam. Usually, the referring physician or health care provider will share the results with you. ...

  11. Ultrasound imaging

    International Nuclear Information System (INIS)

    Wells, P.N.T.

    1983-01-01

    Ultrasound is a form of energy which consists of mechanical vibrations the frequencies of which are so high that they are above the range of human hearing. The lower frequency limit of the ultrasonic spectrum may generally be taken to be about 20 kHz. Most biomedical applications of ultrasound employ frequencies in the range 1-15 MHz. At these frequencies, the wavelength is in the range 1.5 - 0.1 mm in soft tissues, and narrow beams of ultrasound can be generated which propagate through such tissues without excessive attenuation. This chapter begins with brief reviews of the physics of diagnostic ultrasound pulse-echo imaging methods and Doppler imaging methods. The remainder of the chapter is a resume of the applications of ultrasonic imaging to physiological measurement

  12. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... be necessary. Your doctor will explain the exact reason why another exam is requested. Sometimes a follow- ... Ultrasound provides real-time imaging, making it a good tool for guiding minimally invasive procedures such as ...

  13. Prostate Ultrasound

    Medline Plus

    Full Text Available ... be necessary. Your doctor will explain the exact reason why another exam is requested. Sometimes a follow- ... Ultrasound provides real-time imaging, making it a good tool for guiding minimally invasive procedures such as ...

  14. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... frequently used to evaluate the reproductive and urinary systems. Ultrasound is safe, noninvasive and does not use ... and evaluate a variety of urinary and reproductive system disorders in both sexes without x-ray exposure. ...

  15. Prostate Ultrasound

    Medline Plus

    Full Text Available ... top of page Additional Information and Resources RTAnswers.org Radiation Therapy for Prostate Cancer top of page ... to Ultrasound - Prostate Sponsored by Please note RadiologyInfo.org is not a medical facility. Please contact your ...

  16. Prostate Ultrasound

    Medline Plus

    Full Text Available ... with measurements acquired as needed for any treatment planning. detect an abnormal growth within the prostate. help ... end of their bowel (rectum) removed during prior surgery are not good candidates for ultrasound of the ...

  17. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... tip of the transducer is smaller than the standard speculum used when performing a Pap test . A ... both sexes without x-ray exposure. Risks For standard diagnostic ultrasound , there are no known harmful effects ...

  18. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... in the abdomen, arms, legs, neck and/or brain (in infants and children) or within various body organs ... or uterine cancers A transvaginal ultrasound is usually performed to view ...

  19. Prostate Ultrasound

    Medline Plus

    Full Text Available ... is enlarged, also known as benign prostatic hyperplasia (BPH) , with measurements acquired as needed for any treatment ... caption Related Articles and Media Benign Prostatic Hyperplasia (BPH) (Enlargement of the Prostate) Prostate Cancer Ultrasound- and ...

  20. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... the exam. Bringing books, small toys, music or games can help to distract the child and make ... modality for the diagnosis and monitoring of pregnant women and their unborn babies. Ultrasound provides real-time ...

  1. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... uterine cavity . Three-dimensional (3-D) ultrasound permits evaluation of the uterus and ovaries in planes that ... a special study usually done to provide detailed evaluation of the prostate gland, involves inserting a specialized ...

  2. Prostate Ultrasound

    Medline Plus

    Full Text Available ... difficulty urinating or an elevated blood test result. It’s also used to investigate a nodule found during ... difficulty urinating. Because ultrasound provides real-time images, it also can be used to guide procedures such ...

  3. Prostate Ultrasound

    Medline Plus

    Full Text Available ... needle biopsies and fluid aspiration. Risks For standard diagnostic ultrasound , there are no known harmful effects on ... and Resources RTAnswers.org Radiation Therapy for Prostate Cancer top of page This page was reviewed on ...

  4. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... sexes without x-ray exposure. Risks For standard diagnostic ultrasound , there are no known harmful effects on ... and Resources RTAnswers.org Radiation Therapy for Gynecologic Cancers Radiation Therapy for Prostate Cancer top of page ...

  5. Prostate Ultrasound

    Medline Plus

    Full Text Available ... rectum. top of page What are some common uses of the procedure? A transrectal ultrasound of the ... is done because a potential abnormality needs further evaluation with additional views or a special imaging technique. ...

  6. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... legs, neck and/or brain (in infants and children) or within various body organs such as the ... tumors other disorders of the urinary bladder In children, pelvic ultrasound can help evaluate: pelvic masses pelvic ...

  7. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... uterus). Sonohysterography allows for a more in-depth investigation of the uterine cavity . Three-dimensional (3-D) ... to-use and less expensive than other imaging methods. Ultrasound imaging is extremely safe and does not ...

  8. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... is Pelvic Ultrasound Imaging? What are some common uses of the procedure? How should I prepare? What does the equipment look like? How does the procedure work? How is the procedure performed? What will I ...

  9. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... quickly. The ultrasound exam room may have a television. Feel free to ask for your child's favorite ... display screen that looks like a computer or television monitor. The image is created based on the ...

  10. Prostate Ultrasound

    Medline Plus

    Full Text Available ... Images related to Ultrasound - Prostate Sponsored by Please note RadiologyInfo.org is not a medical facility. Please ... is further reviewed by committees from the American College of Radiology (ACR) and the Radiological Society of ...

  11. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... Images related to Ultrasound - Pelvis Sponsored by Please note RadiologyInfo.org is not a medical facility. Please ... is further reviewed by committees from the American College of Radiology (ACR) and the Radiological Society of ...

  12. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... symptoms experienced by women such as: pelvic pain abnormal vaginal bleeding other menstrual problems Ultrasound exams also ... endometrial polyps fibroids cancer, especially in patients with abnormal uterine bleeding Some physicians also use 3-D ...

  13. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... The ultrasound exam room may have a television. Feel free to ask for your child's favorite channel. ... performed over an area of tenderness, you may feel pressure or minor pain from the transducer. Once ...

  14. Prostate Ultrasound

    Medline Plus

    Full Text Available ... also known as benign prostatic hyperplasia (BPH) , with measurements acquired as needed for any treatment planning. detect ... areas of the body while other areas, especially air-filled lungs, are poorly suited for ultrasound. For ...

  15. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... ovarian cysts and uterine fibroids ovarian or uterine cancers A transvaginal ultrasound is usually performed to view ... detect: uterine anomalies uterine scars endometrial polyps fibroids cancer, especially in patients with abnormal uterine bleeding Some ...

  16. Prostate Ultrasound

    Medline Plus

    Full Text Available ... rectum. top of page What are some common uses of the procedure? A transrectal ultrasound of the ... community, you can search the ACR-accredited facilities database . This website does not provide cost information. The ...

  17. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... kidneys. top of page What are some common uses of the procedure? In women, a pelvic ultrasound ... community, you can search the ACR-accredited facilities database . This website does not provide cost information. The ...

  18. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... of the reflected sound waves (called the Doppler effect). A computer collects and processes the sounds and ... standard diagnostic ultrasound , there are no known harmful effects on humans. top of page What are the ...

  19. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... sends out high-frequency sound waves (that the human ear cannot hear) into the body and then ... ultrasound , there are no known harmful effects on humans. top of page What are the limitations of ...

  20. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... various body organs such as the liver or kidneys. top of page What are some common uses ... women, a pelvic ultrasound exam can help identify: kidney stones bladder tumors other disorders of the urinary ...

  1. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... the ovaries. Transvaginal ultrasound also evaluates the myometrium (muscular walls of the uterus). Sonohysterography allows for a ... and evaluate a variety of urinary and reproductive system disorders in both sexes without x-ray exposure. ...

  2. Prostate Ultrasound

    Medline Plus

    Full Text Available ... echoes from the tissues in the body. The principles are similar to sonar used by boats and ... work? Ultrasound imaging is based on the same principles involved in the sonar used by bats, ships ...

  3. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... echoes from the tissues in the body. The principles are similar to sonar used by boats and ... work? Ultrasound imaging is based on the same principles involved in the sonar used by bats, ships ...

  4. Prostate Ultrasound

    Medline Plus

    Full Text Available ... is at high risk for cancer. In this case, a biopsy is performed and an ultrasound probe ... will share the results with you. In some cases, the radiologist may discuss results with you at ...

  5. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... ovaries. Transvaginal ultrasound also evaluates the myometrium (muscular walls of the uterus). Sonohysterography allows for a more ... needle insertion) is usually minimal because the rectal wall is relatively insensitive to the pain in the ...

  6. Prostate Ultrasound

    Medline Plus

    Full Text Available ... uses sound waves to produce pictures of a man’s prostate gland and to help diagnose symptoms such ... also called transrectal ultrasound, provides images of a man's prostate gland and surrounding tissue. The exam typically ...

  7. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... consist of a console containing a computer and electronics, a video display screen and a transducer that ... the preferred imaging modality for the diagnosis and monitoring of pregnant women and their unborn babies. Ultrasound ...

  8. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... insertion. top of page How does the procedure work? Ultrasound imaging is based on the same principles ... the transducer is pressed against the skin, it directs small pulses of inaudible, high-frequency sound waves ...

  9. Prostate Ultrasound

    Medline Plus

    Full Text Available ... gel. top of page How does the procedure work? Ultrasound imaging is based on the same principles ... the transducer is pressed against the skin, it directs small pulses of inaudible, high-frequency sound waves ...

  10. A Diagnostic Ultrasound Imaging System

    International Nuclear Information System (INIS)

    Lee, Seong Woo

    1999-01-01

    The ability to see the internal organs of the human body in a noninvasive way is a powerful diagnostic tool of modern medicine. Among these imaging modalities such as X-ray, MRI, and ultrasound. MRI and ultrasound are presenting much less risk of undesirable damage of both patient and examiner. In fact, no deleterious effects have been reported as a result of clinical examination by using MRI and ultrasound diagnostic equipment. As a result, their market volume has been rapidly increased. MRI has a good resolution. but there are a few disadvantages such as high price. non-real-time imaging capability. and expensive diagnostic cost. On the other hand, the ultrasound imaging system has inherently poor resolution as compared with X-ray and MRI. In spite of its poor resolution, the ultrasound diagnostic equipment is lower in price and has an ability of real-time imaging as compared with the others. As a result, the ultrasound imaging system has become general and essential modality for imaging the internal organs of human body. In this review various researches and developments to enhance the resolution of the ultrasound images are explained and future trends of the ultrasound imaging technology are described

  11. Role of Measurement of the Maximum Intimal-Medial Thickness in the Brain Health Examination Program

    OpenAIRE

    上山, 憲司; 中川原, 譲二; 武田, 利兵衛; 中村, 博彦

    2005-01-01

    The maximum intimal-medial thickness (Max-IMT) of the carotid artery wall (Max-IMT) was measured by ultrasonography in 1,932 people checked in the brain health examination program in our hospital. We studied relationship Max-IMT and age, systolic blood pressure, presence of asymptomatic cerebral infarction. Five hundreds seventy-two people (29.9%) had atherosclerotic thickness of Max-IMT that was more than 1.1 mm. Normal Max-IMT that less than 1.0 mm was observed in 1,360 people (70.1%). More...

  12. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... body tissue through which the sound travels. A small amount of gel is put on the skin to allow the sound waves to travel from the transducer to the examined area within the body and then back again. Ultrasound ...

  13. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... the amplitude (loudness), frequency (pitch) and time it takes for the ultrasound signal to return from the area within the patient that is being examined to the transducer (the device placed on the patient's skin to send and ...

  14. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... used to help physicians evaluate symptoms such as: pain swelling infection Ultrasound is a useful way of examining many of the body's internal organs, including but not limited to the: heart and blood vessels, including the abdominal aorta and its major branches liver gallbladder spleen ...

  15. Cost-Effectiveness of Elderly Health Examination Program: The Example of Hypertension Screening

    Directory of Open Access Journals (Sweden)

    Bing-Hwa Deng

    2007-01-01

    Full Text Available The National Health Insurance (NHI and social welfare agencies have implemented the Elderly Health Examination Program (EHEP for years. No study has ever attempted to evaluate whether this program is cost-effective. The purposes of this study were, firstly, to understand the prevalence and incidence rates of hypertension and, secondly, to estimate the cost and effectiveness of the EHEP, focusing on hypertension screening. The data sources were: (1 hypertension and clinical information derived from the 1996 and 1997 EHEP, which was used to generate prevalence and incidence rates of hypertension; and (2 claim data of the NHI that included treatment costs of stroke patients (in-and outpatients. Hypothetical models were used to evaluate the cost-effectiveness of the hypertension screening program in various conditions. Sensitivity analysis was also employed to evaluate the effect of each estimation indicator on the cost and effectiveness of the hypertension screening program. A total of 28.3% of the elderly population in Kaohsiung (25,174 of 88,812 participated in the 1996 EHEP; 14,915 of them participated in the following 1997 EHEP, with a retention rate of 59.3%. Criteria from the Sixth Report of the Joint National Committee on Detection, Evaluation, and Treatment of High Blood Pressure (JNC VI (systolic blood pressure/diastolic blood pressure ≥ 160/95mmHg or taking antihypertensive drugs were used; we found that prevalence and incidence rates of hypertension were 24.6% and 6.6%, respectively. Hypertension rates are increasing in the aging process as shown in both prevalence and incidence models. In comparison with non-participants, the prevalence model indicates that each hypertension patient who had attended the EHEP not only saved NT$34,570–34,890 in medical and associated costs, but also increased their lifespan by 128 days. The present findings suggest that the EHEP is a cost-effective program with health and social welfare policy

  16. An examination of stress, coping, and adaptation in nurses in a recovery and monitoring program.

    Science.gov (United States)

    Bowen, Marie Katherine; Taylor, Kathleen P; Marcus-Aiyeku, Ulanda; Krause-Parello, Cheryl A

    2012-10-01

    Addiction rates in nurses are higher than in the general population. The relationship between stress, coping, and adaptation in nurses (N = 82) enrolled in a recovery and monitoring program in the state of New Jersey was examined. Social support, a variable tested as a mediator of this relationship, was also examined. Participants completed the Perceived Stress Scale, Multidimensional Scale of Perceived Social Support, and Psychological General Well-Being Index. Negative relationships were found between stress and social support and stress and well-being, and a positive relationship was found between social support and well-being (all ps prevent potential untoward consequences. Ultimately, methods to strengthen social support and social networks will enhance the probability of sustained recovery, relapse prevention, and safe reentry into nursing practice. Implications for behavioral health providers and health care practitioners are discussed.

  17. Comparisons of clinic effects between DTPA renal dynamic imaging and B-ultrasound examination in diagnosis and treatment of infantile hydronephrosis

    International Nuclear Information System (INIS)

    Zhang Lixia; Qi Lili; Shen Wenhua; Luo Yunxiao

    2011-01-01

    Objective: To study the clinic value of DTPA renal dynamic imaging in the functional evaluation of infantile hydronephrosis and clarify its application value, and lay the foundation for DTPA renal dynamic imaging in diagnosis and treatment of infantile hydronephrosis. Methods: 70 infants with hydronephrosis in our hospital whose mean age was (2.32±2.1) years (rang from 37 d to 6 years) were selected. There were 56 males and 14 females. 18 normal infants with mean age (2.66±2.01) years (rang from 41 d to 6 years, 15 males and 3 females) were selected as control group during the same period. Technetium-99m-labelled DTPA ( 99m Tc-DTPA) was taken as agent, and the dose of 99m Tc was 18.5 MBq per infant. GE Infinia SPECT was used as imaging equipment. The time-activity curve was generated in the imaging system automatically. The glomerular filtration rate (GFR) was detected by DTPA renal dynamic imaging through drawing the region of interest (ROI). Results: 83 kidneys were suffered from hydronephrosis diagnosed by B-ultrasound among 70 infant patients, while 104 abnormal kidneys were diagnosed by renal dynamic imaging. The detection rate of renal dysfunction by renal dynamic imaging was higher than that of B-ultrasound (t=7.751, P=0.005). Among 83 kidneys suffered from hydronephrosis diagnosed by B-ultrasound, the continued rising type was 56 cases (67.47% ); the parabolic type was cases (7.23% ); the high linear extension type was 14 cases (16.87% ); and the low linear extension type was 7 cases (8.43% ). The GFR value of linear extension type was lower than normal control group, the difference was significant (P<0.05), and the another three types had no significant differences compared with control group. Conclusion: For infantile hydronephrosis, DTPA renal dynamic imaging can observe not only the abnormal morphology of kidney, but also the function of split kidney; and it can provide objective basis for diagnosis and treatment of infantile hydronephrosis. (authors)

  18. 46 CFR 71.50-27 - Alternative Hull Examination (AHE) program options: Divers or underwater remotely operated...

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 3 2010-10-01 2010-10-01 false Alternative Hull Examination (AHE) program options...-27 Alternative Hull Examination (AHE) program options: Divers or underwater remotely operated vehicle... operations; (2) Provide permanent hull markings, a temporary grid system of wires or cables spaced not more...

  19. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... guide biopsy of breast cancer ( see the Ultrasound-Guided Breast Biopsy page . diagnose a variety of heart ... Articles and Media Angioplasty and Vascular Stenting Ultrasound-Guided Breast Biopsy Obstetric Ultrasound Ultrasound - Prostate Biopsies - Overview ...

  20. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... Index A-Z General Ultrasound Ultrasound imaging uses sound waves to produce pictures of the inside of ... pictures of the inside of the body using sound waves. Ultrasound imaging, also called ultrasound scanning or ...

  1. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... What are the limitations of General Ultrasound Imaging? What is General Ultrasound Imaging? Ultrasound is safe and ... be heard with every heartbeat. top of page What are some common uses of the procedure? Ultrasound ...

  2. Barriers and enabling factors for work-site physical activity programs: a qualitative examination.

    Science.gov (United States)

    Fletcher, Gena M; Behrens, Timothyh K; Domina, Lorie

    2008-05-01

    Work sites offer a productive setting for physical activity (PA) promoting interventions. Still, PA participation remains low. Thus, the purpose of this study was to examine the reasoning behind commonly reported barriers and enabling factors to participation in PA programs in a work-site setting. Employees from a large city government were recruited to participate in focus groups, stratified by white- and blue-collar occupations. Responses from open-ended questions about factors influencing participation in PA programs were audio recorded and transcribed verbatim. Resulting data were analyzed with open and axial coding. The sample consisted of 60 employees composing 9 focus groups. Although time was the most common barrier between both groups, white-collars workers responded that scheduling and work conflicts were the most common barrier concerning time. Blue-collar workers indicated shift work as their most common barrier. In addition, health was a significant enabling factor for both occupational categories. White-collar workers were much more concerned with appearances and were more highly motivated by weight loss and the hopefulness of quick results than were blue-collar workers. These findings are important in the understanding of PA as it relates to the reasoning behind participation in work-site programs in regard to occupational status.

  3. An Examination of an Iconic Trap-Neuter-Return Program: The Newburyport, Massachusetts Case Study

    Directory of Open Access Journals (Sweden)

    Daniel D. Spehar

    2017-10-01

    Full Text Available The use of trap-neuter-return (TNR as a humane alternative to the lethal management of free-roaming cats has been on the rise for several decades in the United States; however a relative paucity of data from TNR programs exists. An iconic community-wide TNR effort; initiated in 1992 and renowned for having eliminated hundreds of free-roaming cats from the Newburyport; Massachusetts waterfront; is cited repeatedly; yet few details appear in the literature. Although the presence of feline population data was quite limited; a detailed narrative emerged from an examination of contemporaneous reports; extant TNR program documents; and stakeholder testimony. Available evidence indicates that an estimated 300 free-roaming cats were essentially unmanaged prior to the commencement of the TNR program; a quick reduction of up to one-third of the cats on the waterfront was attributed to the adoption of sociable cats and kittens; the elimination of the remaining population; over a 17-year period; was ascribed to attrition. These findings illuminate the potential effectiveness of TNR as a management practice; as well as call attention to the need for broad adoption of systematic data collection and assessment protocols.

  4. Examining the Effect of Social Values Education Program Being Applied to Nursery School Students upon Acquiring Social Skills

    Science.gov (United States)

    Sapsaglam, Özkan; Ömeroglu, Esra

    2016-01-01

    This study was conducted in an attempt to develop Social Values Education Program aimed at nursery school students and examine the effect of Social Values Education Program upon the social skill acquisition of nursery school students. The effect of the education program that was developed within the scope of the study upon the social skill…

  5. The Devil Is in the Details: Examining the Evidence for "Proven" School-Based Drug Abuse Prevention Programs

    Science.gov (United States)

    Gandhi, Allison Gruner; Murphy-Graham, Erin; Petrosino, Anthony; Chrismer, Sara Schwartz; Weiss, Carol H.

    2007-01-01

    In an effort to promote evidence-based practice, government officials, researchers, and program developers have developed lists of model programs in the prevention field. This article reviews the evidence used by seven best-practice lists to select five model prevention programs. The authors' examination of this research raises questions about the…

  6. Ultrasound appearance of knuckle pads

    Energy Technology Data Exchange (ETDEWEB)

    Lopez-Ben, R. [Univ. of Alabama, Birmingham (United States). Dept. of Diagnostic Radiology; Dehghanpisheh, K.; Chatham, W.W.; Alarcon, G.S. [Univ. of Alabama, Birmingham (United States). Dept. of Medicine; Lee, D.H.; Oakes, J. [Univ. of Alabama, Birmingham (United States). Dept. of Surgery

    2006-11-15

    We describe the ultrasound appearance of knuckle pads. Retrospective analysis of imaging in a series of five patients initially referred for evaluation of periarticular soft-tissue swelling of the hands involving the dorsum of the PIP and MP joints. Two patients had associated Dupuytren's contractures. Ultrasound and radiographs of the hands in all patients were reviewed and correlated with clinical history and physical exams. Radiographs in four patients demonstrated dorsal soft-tissue thickening. Ultrasound exams showed increased dorsal subcutaneous thickening, with either diffuse or focal hypoechoic areas corresponding to the areas of soft-tissue fullness identified on physical exam. No erosions or synovial proliferation were identified either by radiographs or ultrasound of the underlying joints. Knuckle pads can sometimes be difficult to distinguish from synovitis on physical examination. Musculoskeletal ultrasound can quickly identify these superficial lesions and exclude underlying synovial proliferation.

  7. Examining the effectiveness of micro-enterprise development programs in Malaysia

    Directory of Open Access Journals (Sweden)

    Noor Raihani Zainol

    2017-06-01

    Full Text Available Previous studies on socioeconomic development have examined the effect of development initiatives (i.e., access to finance and training on several socioeconomic indicators (i.e., income, empowerment, asset, quality of life, employment. These studies have focused mostly on the outcomes of specific types of programs offered by specific development organizations. This study however focuses on informal women micro-entrepreneurs’ participation in various development programs available to them and their influence on entrepreneurial competencies, human capital development, competitive advantages, economic vulnerability, supportive environment, and performance of micro-enterprises. This cross-sectional study adopted the purposive random sampling method and collected data from 384 informal women entrepreneurs from the local markets in different districts of Kelantan, Malaysia. The findings show that the development program participants have relatively higher levels of entrepreneurial competencies, human capital development, and higher levels of enterprise performance compared to non-participants. It is also noted that the level of economic vulnerability is relatively low among participants compared to non-participants. However, these findings contradict most of the earlier studies that show a significant positive impact of micro-credit on socio-economic wellbeing, as the difference in entrepreneurial competencies, human capital development, economic vulnerability, and performance of micro-enterprises among participants and non-participants in this study is not statistically significant. However, findings reported significantly higher levels of competitive advantages, and better supportive environment among the participants compared to the non-participants. Development organizations should therefore focus on expanding their outreach to spread the positive effects of their development programs towards uplifting the economic condition of low and middle

  8. Objective and structured assessment of lung ultrasound competence

    DEFF Research Database (Denmark)

    Skaarup, Søren Helbo; Laursen, Christian B.; Bjerrum, Anne Sofie

    2017-01-01

    RATIONALE: Point-of-care lung ultrasound imaging has substantial diagnostic value and is widely used in respiratory, emergency and critical care medicine. Like other ultrasound examinations, lung ultrasound is operator-dependent. The current recommendations for competence in lung ultrasound sets...... a fixed number of ultrasound procedures to be performed without considering different learning rates. Recommendations do not consider different uses of lung ultrasound across specialties. OBJECTIVE: To create a reliable, valid and feasible instrument to assess lung ultrasound competence that includes...... 23 ultrasound operators of different competence levels. Examination time was measured and skill was rated by experienced observers using the assessment tool. Inter-rater agreement was examined by two observers in 9 lung ultrasound examinations. RESULTS: Consensus was obtained within 3 Delphi rounds...

  9. Examining relational empowerment for elementary school students in a yPAR program.

    Science.gov (United States)

    Langhout, Regina Day; Collins, Charles; Ellison, Erin Rose

    2014-06-01

    This paper joins relational empowerment, youth empowerment, and Bridging Multiple Worlds frameworks to examine forms of relational empowerment for children in two intermediary institutions-school and a youth participatory action research after-school program (yPAR ASP). Participants were twelve children, most of whom were Latina/o and from im/migrant families, enrolled in a yPAR ASP for 2 years. A mixed-method approach was utilized; we analyzed children's interviews, self-defined goals, and their social networks to examine their experiences of relational empowerment. We conclude that children experienced each of the five relational empowerment factors-collaborative competence, bridging social divisions, facilitating others' empowerment, mobilizing networks, and passing on a legacy-in the yPAR ASP setting, and some factors in school. These experiences, however, were more pronounced in the yPAR ASP setting. Additionally, social network analyses revealed that a small but meaningful percentage of actors bridged worlds, especially home and family, but by year 2, also school and the yPAR ASP. Finally, most helpers for school-based goals came from school, but a sizable number came from family, friends, and home worlds, and by year 2, also came from the yPAR ASP. Implications range from theoretical to methodological development, including the use of social network analysis as a tool to descriptively examine relational power in context.

  10. Therapeutic ultrasound

    International Nuclear Information System (INIS)

    Crum, Lawrence A

    2004-01-01

    The use of ultrasound in medicine is now quite commonplace, especially with the recent introduction of small, portable and relatively inexpensive, hand-held diagnostic imaging devices. Moreover, ultrasound has expanded beyond the imaging realm, with methods and applications extending to novel therapeutic and surgical uses. These applications broadly include: tissue ablation, acoustocautery, lipoplasty, site-specific and ultrasound mediated drug activity, extracorporeal lithotripsy, and the enhancement of natural physiological functions such as wound healing and tissue regeneration. A particularly attractive aspect of this technology is that diagnostic and therapeutic systems can be combined to produce totally non-invasive, imageguided therapy. This general lecture will review a number of these exciting new applications of ultrasound and address some of the basic scientific questions and future challenges in developing these methods and technologies for general use in our society. We shall particularly emphasize the use of High Intensity Focused Ultrasound (HIFU) in the treatment of benign and malignant tumors as well as the introduction of acoustic hemostasis, especially in organs which are difficult to treat using conventional medical and surgical techniques. (amum lecture)

  11. 46 CFR 115.620 - Description of the Alternative Hull Examination (AHE) Program for certain passenger vessels.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 4 2010-10-01 2010-10-01 false Description of the Alternative Hull Examination (AHE... ACCOMMODATIONS FOR MORE THAN 49 PASSENGERS INSPECTION AND CERTIFICATION Hull and Tailshaft Examinations § 115.620 Description of the Alternative Hull Examination (AHE) Program for certain passenger vessels. The Alternative...

  12. Evaluation of breast self-examination program using Health Belief Model in female students

    Directory of Open Access Journals (Sweden)

    Mitra Moodi

    2011-01-01

    Full Text Available Background: Breast cancer has been considered as a major health problem in females, because of its high incidence in recent years. Due to the role of breast self-examination (BSE in early diagnosis and prevention of morbidity and mortality rate of breast cancer, promoting student knowledge, capabilities and attitude are required in this regard. This study was conducted to evaluation BSE education in female University students using Health Belief Model. Methods: In this semi-experimental study, 243 female students were selected using multi-stage randomized sampling in 2008. The data were collected by validated and reliable questionnaire (43 questions before intervention and one week after intervention. The intervention program was consisted of one educational session lasting 120 minutes by lecturing and showing a film based on HBM constructs. The obtained data were analyzed by SPSS (version11.5 using statistical paired t-test and ANOVA at the significant level of α = 0.05. Results: 243 female students aged 20.6 ± 2.8 years old were studied. Implementing the educational program resulted in increased knowledge and HBM (perceived susceptibility, severity, benefit and barrier scores in the students (p ≤ 0.01. Significant increases were also observed in knowledge and perceived benefit after the educational program (p ≤ 0.05. ANOVA statistical test showed significant difference in perceived benefit score in students of different universities (p = 0.05. Conclusions: Due to the positive effects of education on increasing knowledge and attitude of university students about BSE, the efficacy of the HBM in BSE education for female students was confirmed.

  13. A prospective examination of disease management program use by complex cardiac outpatients.

    Science.gov (United States)

    Gravely, Shannon; Reid, Robert D; Oh, Paul; Ross, Heather; Stewart, Donna E; Grace, Sherry L

    2012-01-01

    The use of disease management programs (DMPs) by patients with cardiovascular disease (CVD) is associated with improved outcomes. Although rates of cardiac rehabilitation (CR) use are well established, less is known about other DMPs. The objectives of this study were to describe the degree of DMP utilization by CVD outpatients, and examine factors related to use. This study represents a secondary analysis of a larger prospective cohort study. In hospital, 2635 CVD inpatients from 11 hospitals in Ontario Canada completed a survey that assessed factors affecting DMP utilization. One year later, 1803 participants completed a mailed survey that assessed DMP utilization. One thousand seventy-three (59.5%) participants reported using at least 1 DMP. Overall, 951 (52.7%) reported participating in cardiac rehabilitation, and among participants with a comorbid indication, 212 (41.2%) reported attending a diabetes education centre, 28 (25.9%) attended stroke rehabilitation, 35 (12.9%) used a heart failure clinic, and 13 (11.7%) attended a smoking cessation program. A multinomial logistic regression analysis showed that compared with no DMP use, participants that attended 1 or multiple programs were younger, married, diagnosed with a myocardial infarction, less likely to have had a percutaneous coronary intervention and had higher perceptions of personal control over their heart condition. There were few differences between participants that used 1 vs multiple DMPs, however, having diabetes or comorbid stroke significantly increased the likelihood of multiple DMP use. Approximately 40% of CVD outpatients do not access DMPs. An integrated approach to vascular disease management appears warranted. Copyright © 2012 Canadian Cardiovascular Society. Published by Elsevier Inc. All rights reserved.

  14. Factors influencing moisture analysis in the 3013 destructive examination surveillance program

    Energy Technology Data Exchange (ETDEWEB)

    Scogin, J. H. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL)

    2017-10-24

    Thermogravimetric analysis of a solid sample with mass spectrometry (TGA-MS) of the evolved gas is used in the destructive examination (DE) portion of the Integrated Surveillance Program to quantify the moisture content of the material stored in a 3013 container. As with any measurement determined from a small sample, the collection, storage, transportation, and handling of the sample can affect its ability to represent the properties of the bulk material. During the course of the DE program, questions have periodically arisen concerning the ability of the moisture sample to reflect reliably the actual moisture content of the entire material stored in the 3013 container. Most concerns are related to the ability to collect a representative sample and to preserve the moisture content of the sample between collection and analysis. Recent delays in analysis caused by maintenance issues with the TGA-MS instrument presented a unique opportunity to document and quantify the effects various factors have on the TGA-MS moisture measurement. This report will use recent data to document the effects that current sample collection and handling practices have on the TGA-MS moisture measurement. Some suggestions will be made which could improve the current sample collection and handling practices for the TGA-MS moisture measurement so that the analytical results more accurately reflect the moisture content of the material stored in the 3013 container.

  15. Factors influencing moisture analysis in the 3013 destructive examination surveillance program

    International Nuclear Information System (INIS)

    Scogin, J. H.

    2017-01-01

    Thermogravimetric analysis of a solid sample with mass spectrometry (TGA-MS) of the evolved gas is used in the destructive examination (DE) portion of the Integrated Surveillance Program to quantify the moisture content of the material stored in a 3013 container. As with any measurement determined from a small sample, the collection, storage, transportation, and handling of the sample can affect its ability to represent the properties of the bulk material. During the course of the DE program, questions have periodically arisen concerning the ability of the moisture sample to reflect reliably the actual moisture content of the entire material stored in the 3013 container. Most concerns are related to the ability to collect a representative sample and to preserve the moisture content of the sample between collection and analysis. Recent delays in analysis caused by maintenance issues with the TGA-MS instrument presented a unique opportunity to document and quantify the effects various factors have on the TGA-MS moisture measurement. This report will use recent data to document the effects that current sample collection and handling practices have on the TGA-MS moisture measurement. Some suggestions will be made which could improve the current sample collection and handling practices for the TGA-MS moisture measurement so that the analytical results more accurately reflect the moisture content of the material stored in the 3013 container.

  16. Program for photon shielding calculations. Examination of approximations on irradiation geometries

    International Nuclear Information System (INIS)

    Isozumi, Yasuhito; Ishizuka, Fumihiko; Miyatake, Hideo; Kato, Takahisa; Tosaki, Mitsuo

    2004-01-01

    Penetration factors and related numerical data in 'Manual of Practical Shield Calculation of Radiation Facilities (2000)', which correspond to the irradiation geometries of point isotropic source in infinite thick material (PI), point isotropic source in finite thick material (PF) and vertical incident to finite thick material (VF), have been carefully examined. The shield calculation based on the PI geometry is usually performed with effective dose penetration factors of radioisotopes given in the 'manual'. The present work cleary shows that such a calculation may lead to an overestimate more than twice larger, especially for thick shield of concrete and water. Employing the numerical data in the 'manual', we have fabricated a simple computer program for the estimation of penetration factors and effective doses of radioisotopes in the different irradiation geometries, i.e., PI, PF and VF. The program is also available to calculate the effective dose from a set of radioisotopes in the different positions, which is necessary for the γ-ray shielding of radioisotope facilities. (author)

  17. Endoscopic ultrasound in the evaluation of chronic upper abdominal pain of unknown etiology: a retrospective chart review examining the efficacy of EUS in determining a new diagnosis.

    Science.gov (United States)

    Thompson, Michelle B; Ramirez, Jonathan C; De La Rosa, Lisa M; Wood, Adam S; Desai, Shiv; Arjunan, Ananth; Song, Juhee; Erickson, Richard A

    2015-02-01

    To explore the utility of endoscopic ultrasound (EUS) in the evaluation of chronic upper abdominal pain (UAP) of undetermined etiology. Chronic UAP is a common problem with a challenging diagnosis and management. The role of EUS in the diagnosis of UAP may minimize additional testing; however, few studies describe the percentage of new diagnoses yielded in these patients. We conducted a retrospective analysis by reviewing electronic medical records at Scott and White Memorial Hospital, Texas A&M Health Sciences Center for patients with abdominal pain for ≥ 12 months not explained by previous workup referred for EUS for chronic UAP from January 1, 1998 through October 1, 2007. Patients with previous EUS in past 12 months were excluded from the study. Patient demographic data and imaging performed 6 months before and 24 months after EUS were reviewed and results documented. EUS was successful at diagnosing a new clinical etiology of chronic UAP in 33 patients (8.89%) with previous workup that was unrevealing for a definitive diagnosis. The most frequent diagnoses included pancreaticobiliary tree abnormalities, chronic pancreatitis, and fatty liver disease. Our results support the fact that the majority of patients UAP with prior imaging will have no identifiable organic etiology found on EUS to explain their pain; however, we suggest that EUS be considered in patients with suspected pancreatic or biliary pathology.

  18. Prostate Ultrasound

    Medline Plus

    Full Text Available ... the prostate. help diagnose the cause of a man's infertility. A transrectal ultrasound of the prostate gland is typically used to help diagnose symptoms such as: a nodule felt by a physician during a routine physical exam or prostate cancer screening exam. an elevated ...

  19. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... and Resources RTAnswers.org Radiation Therapy for Gynecologic Cancers Radiation Therapy for Prostate Cancer top of page This page was reviewed on ... with caption Pediatric Content Some imaging tests and treatments have special pediatric considerations. ... Images related to Ultrasound - Pelvis Sponsored by Please ...

  20. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... ultrasound exams are also used to monitor the health and development of an embryo or fetus during pregnancy. See the ... can help to identify and evaluate a variety of urinary and reproductive system disorders in both sexes without x-ray exposure. ...

  1. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... of the reflected sound waves (called the Doppler effect). A computer collects and processes the sounds and creates graphs ... Ultrasound provides real-time imaging, making it a good tool for guiding minimally ... known harmful effects on humans. top of page What are the ...

  2. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available Toggle navigation Test/Treatment Patient Type Screening/Wellness Disease/Condition Safety En Español More Info Images/Videos About Us News Physician ... blood vessels. Ultrasound imaging is a noninvasive medical test that helps physicians diagnose and treat medical conditions. ...

  3. Prostate Ultrasound

    Medline Plus

    Full Text Available ... symptoms such as difficulty urinating or an elevated blood test result. It’s also used to investigate a nodule ... exam or prostate cancer screening exam. an elevated blood test result. difficulty urinating. Because ultrasound provides real-time ...

  4. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... in which needles are used to extract a sample of cells from organs for laboratory testing. Doppler ultrasound images can help the physician to see and evaluate: blockages to blood flow (such as clots) narrowing of vessels tumors ...

  5. Prostate Ultrasound

    Medline Plus

    Full Text Available ... exam or prostate cancer screening exam. an elevated blood test result. difficulty urinating. Because ultrasound provides real-time images, it also can be used to guide procedures such as needle biopsies , in which a needle is used to sample cells (tissue) from an abnormal area in the ...

  6. Prostate Ultrasound

    Medline Plus

    Full Text Available ... do not use ionizing radiation (as used in x-rays ), thus there is no radiation exposure to the ... tissues that do not show up well on x-ray images. Ultrasound causes no health problems and may ...

  7. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... do not use ionizing radiation (as used in x-rays ), thus there is no radiation exposure to the ... tissues that do not show up well on x-ray images. Ultrasound is the preferred imaging modality for ...

  8. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... the patient. Because ultrasound images are captured in real-time, they can show the structure and movement of ... by a computer, which in turn creates a real-time picture on the monitor. One or more frames ...

  9. Summer Treatment Program for Preschoolers with Externalizing Behavior Problems: a Preliminary Examination of Parenting Outcomes.

    Science.gov (United States)

    Graziano, Paulo A; Ros, Rosmary; Hart, Katie C; Slavec, Janine

    2017-11-07

    Within an at-risk sample of preschoolers with externalizing behavior problems (EBP), the current study examined the initial promise of a multimodal intervention, the Summer Treatment Program for Pre-Kindergarteners (STP-PreK), in improving parenting outcomes. Using an open trial design, 154 parents and their preschool children (73% male; M age  = 5.06 years; 82% Hispanic/Latino background) with at-risk or clinically elevated levels of EBP (57% of which were referred by schools or mental health/medical professionals) completed a baseline and post-treatment assessment. A subsample of 90 families completed a follow-up assessment approximately 6 to 9 months after treatment completion. Parental measures of parenting stress and discipline strategies were collected across all three assessments. Observational data were also collected across all assessments during a 5-min standardized child-led play situation and a 5-min parent-led clean up task. The parenting component of the STP-PreK included a School Readiness Parenting Program (SRPP) of which the behavioral management component was implemented via a Parent-Child Interaction Therapy (PCIT) adaptation (8 weekly group sessions with 15-20 parents in each group, lack of requirement of "mastery" criteria). All parenting outcomes (both ratings and observed) significantly improved after the intervention (Cohen's d mean effect size across measures 0.89) with all effects being maintained at the 6-9 month follow-up. These findings highlight the initial promise of our SRPP's PCIT adaptation in targeting multiple aspects of parenting while yielding comparable parenting skills acquisition compared to traditional individual PCIT.

  10. Bulk Electrical Cable Non-Destructive Examination Methods for Nuclear Power Plant Cable Aging Management Programs

    Energy Technology Data Exchange (ETDEWEB)

    Glass, Samuel W. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Jones, Anthony M. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Fifield, Leonard S. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Hartman, Trenton S. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States)

    2016-09-01

    This Pacific Northwest National Laboratory milestone report describes progress to date on the investigation of nondestructive test methods focusing particularly on bulk electrical test methods that provide key indicators of cable aging and damage. The work includes a review of relevant literature as well as hands-on experimental verification of inspection capabilities. As nuclear power plants consider applying for second, or subsequent, license renewal to extend their operating period from 60 years to 80 years, it is important to understand how the materials installed in plant systems and components will age during that time and develop aging management programs to assure continued safe operation under normal and design basis events (DBE). Normal component and system tests typically confirm the cables can perform their normal operational function. The focus of the cable test program, however, is directed toward the more demanding challenge of assuring the cable function under accident or DBE. The industry has adopted 50% elongation at break (EAB) relative to the un-aged cable condition as the acceptability standard. All tests are benchmarked against the cable EAB test. EAB, however, is a destructive test so the test programs must apply an array of other nondestructive examination (NDE) tests to assure or infer the overall set of cable’s system integrity. Assessment of cable integrity is further complicated in many cases by vendor’s use of dissimilar material for jacket and insulation. Frequently the jacket will degrade more rapidly than the underlying insulation. Although this can serve as an early alert to cable damage, direct test of the cable insulation without violating the protective jacket becomes problematic. This report addresses the range of bulk electrical NDE cable tests that are or could be practically implemented in a field-test situation with a particular focus on frequency domain reflectometry (FDR). The FDR test method offers numerous advantages

  11. A Comparative Cross-Cultural Examination of Community Art Education Programs in South Korea and the United States

    Science.gov (United States)

    Shin, Ryan; Kim, Junghee

    2014-01-01

    The authors conducted comparative cross-cultural research to examine a select group of the available and more noteworthy art education organizations and their programs after observing significant differences in the community art education programs offered in Tucson, Arizona, and Anyang, South Korea. The study reports several major differences…

  12. Droplets, Bubbles and Ultrasound Interactions.

    Science.gov (United States)

    Shpak, Oleksandr; Verweij, Martin; de Jong, Nico; Versluis, Michel

    2016-01-01

    The interaction of droplets and bubbles with ultrasound has been studied extensively in the last 25 years. Microbubbles are broadly used in diagnostic and therapeutic medical applications, for instance, as ultrasound contrast agents. They have a similar size as red blood cells, and thus are able to circulate within blood vessels. Perfluorocarbon liquid droplets can be a potential new generation of microbubble agents as ultrasound can trigger their conversion into gas bubbles. Prior to activation, they are at least five times smaller in diameter than the resulting bubbles. Together with the violent nature of the phase-transition, the droplets can be used for local drug delivery, embolotherapy, HIFU enhancement and tumor imaging. Here we explain the basics of bubble dynamics, described by the Rayleigh-Plesset equation, bubble resonance frequency, damping and quality factor. We show the elegant calculation of the above characteristics for the case of small amplitude oscillations by linearizing the equations. The effect and importance of a bubble coating and effective surface tension are also discussed. We give the main characteristics of the power spectrum of bubble oscillations. Preceding bubble dynamics, ultrasound propagation is introduced. We explain the speed of sound, nonlinearity and attenuation terms. We examine bubble ultrasound scattering and how it depends on the wave-shape of the incident wave. Finally, we introduce droplet interaction with ultrasound. We elucidate the ultrasound-focusing concept within a droplets sphere, droplet shaking due to media compressibility and droplet phase-conversion dynamics.

  13. Point-of-Care Ultrasound: A Trend in Health Care.

    Science.gov (United States)

    Buerger, Anita M; Clark, Kevin R

    2017-11-01

    To discuss the current and growing use of point-of-care (POC) ultrasound in the management and care of patients. Several electronic research databases were searched to find articles that emphasized the use of POC ultrasound by health care providers who manage and treat critically ill or injured patients. Thirty-five relevant peer-reviewed journal articles were selected for this literature review. Common themes identified in the literature included the use of POC ultrasound in emergency medicine, military medicine, and remote care; comparison of POC ultrasound to other medical imaging modalities; investigation of the education and training required for nonimaging health care professionals who perform POC ultrasound in their practices; and discussion of the financial implications and limitations of POC ultrasound. POC ultrasound provides clinicians with real-time information to better manage and treat critically ill or injured patients in emergency medicine, military medicine, and remote care. In addition to providing immediate bedside diagnostic information, use of POC ultrasound has increased because of concerns regarding radiation protection. Finally, the expansion of POC ultrasound to other specialty areas requires nonimaging health care professionals to perform bedside ultrasound examinations and interpret the resulting images. Because POC ultrasound is user-dependent, adequate training is essential for all who perform and interpret the examinations. Research involving POC ultrasound will continue as innovations and confidence in ultrasound applications advance. Future research should continue to examine the broad use of POC ultrasound in patient care and management. ©2017 American Society of Radiologic Technologists.

  14. 46 CFR 115.625 - Eligibility requirements for the Alternative Hull Examination (AHE) Program for certain passenger...

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 4 2010-10-01 2010-10-01 false Eligibility requirements for the Alternative Hull... OVERNIGHT ACCOMMODATIONS FOR MORE THAN 49 PASSENGERS INSPECTION AND CERTIFICATION Hull and Tailshaft Examinations § 115.625 Eligibility requirements for the Alternative Hull Examination (AHE) Program for certain...

  15. Electronic Engineering Technology Program Exit Examination as an ABET and Self-Assessment Tool

    Science.gov (United States)

    Thomas, Gary; Darayan, Shahryar

    2018-01-01

    Every engineering, computing, and engineering technology program accredited by the Accreditation Board for Engineering and Technology (ABET) has formulated many and varied self-assessment methods. Methods used to assess a program for ABET accreditation and continuous improvement are for keeping programs current with academic and industrial…

  16. A Qualitative Examination of Challenges Influencing Doctoral Students in an Online Doctoral Program

    Science.gov (United States)

    Deshpande, Anant

    2016-01-01

    The main purpose of the study was to investigate the challenges faced by students in completion of an online doctoral program at the University of Liverpool, Online Doctoral Business Administration program. We analyse the responses of 91 doctoral students in an online DBA program. Based on the exploratory qualitative study themes were developed…

  17. Ultrasound diagnosis of rectus sheath hematoma

    International Nuclear Information System (INIS)

    Hwang, M. S.; Chang, J. C.; Rhee, C. B.

    1984-01-01

    6 cases of rectus sheath hematoma were correctly diagnosed by ultrasound. 2 cases had bilateral rectus sheath hematoma and 4 cases were unilateral. On ultrasound finding, relatively well defined oval or spindle like cystic mass situated in the area of rectus muscle on all cases. Ultrasound examination may give more definite diagnosis and extension rectus sheath hematoma and also helpful to follow up study of hematoma

  18. Diagnostic accuracy of history, physical examination, and bedside ultrasound for diagnosis of extremity fractures in the emergency department: a systematic review.

    Science.gov (United States)

    Joshi, Nikita; Lira, Alena; Mehta, Ninfa; Paladino, Lorenzo; Sinert, Richard

    2013-01-01

    Understanding history, physical examination, and ultrasonography (US) to diagnose extremity fractures compared with radiography has potential benefits of decreasing radiation exposure, costs, and pain and improving emergency department (ED) resource management and triage time. The authors performed two electronic searches using PubMed and EMBASE databases for studies published between 1965 to 2012 using a strategy based on the inclusion of any patient presenting with extremity injuries suspicious for fracture who had history and physical examination and a separate search for US performed by an emergency physician (EP) with subsequent radiography. The primary outcome was operating characteristics of ED history, physical examination, and US in diagnosing radiologically proven extremity fractures. The methodologic quality of the studies was assessed using the quality assessment of studies of diagnostic accuracy tool (QUADAS-2). Nine studies met the inclusion criteria for history and physical examination, while eight studies met the inclusion criteria for US. There was significant heterogeneity in the studies that prevented data pooling. Data were organized into subgroups based on anatomic fracture locations, but heterogeneity within the subgroups also prevented data pooling. The prevalence of fracture varied among the studies from 22% to 70%. Upper extremity physical examination tests have positive likelihood ratios (LRs) ranging from 1.2 to infinity and negative LRs ranging from 0 to 0.8. US sensitivities varied between 85% and 100%, specificities varied between 73% and 100%, positive LRs varied between 3.2 and 56.1, and negative LRs varied between 0 and 0.2. Compared with radiography, EP US is an accurate diagnostic test to rule in or rule out extremity fractures. The diagnostic accuracy for history and physical examination are inconclusive. Future research is needed to understand the accuracy of ED US when combined with history and physical examination for upper

  19. Soleus muscle injury: sensitivity of ultrasound patterns

    Energy Technology Data Exchange (ETDEWEB)

    Balius, Ramon [Sport Catalan Council, Generalitat de Catalunya, Barcelona (Spain); Clinica CMI Diagonal, Barcelona (Spain); Rodas, Gil [F.C. Barcelona Medical Services, Barcelona (Spain); Pedret, Carles [Clinica CMI Diagonal, Barcelona (Spain); Clinica Mapfre de Medicina del Tenis, Sports Medicine and Imaging Department, Barcelona (Spain); Centre de Diagnostic per Imatge de Tarragona, Tarragona (Spain); Capdevila, Lluis [Universitat Autonoma de Barcelona, Laboratory of Sport Psychology, Barcelona (Spain); Alomar, Xavier [Clinica Creu Blanca, Barcelona (Spain); Bong, David A. [Instituto Poal de Reumatologia, Barcelona (Spain)

    2014-06-15

    To assess the sensitivity of ultrasound in detecting soleus muscle lesions diagnosed on magnetic resonance imaging (MRI) and to characterize their location, ultrasound pattern, and evolution. Ultrasound and MRI studies were performed between May 2009 and February 2013 on all patients who presented to the Medical Services Clinic of the Catalan Sport Council with the initial onset of sharp pain in the calf compatible with injury of the soleus muscle. An inter-observer ultrasound reliability study was also performed. A total of 55 cases of soleus injury were studied prospectively (22 with right leg involvement, 33 left) by ultrasound and MRI, which was utilized as the ''gold standard.'' In MRI studies, 24 cases (43.7 %) had myofascial injuries that were localized in the posterior aponeurosis (PMF) in 15 cases (27.3 %) and in the anterior aponeurosis (AMF) in 9 (16.4 %). Thirty-one cases (56.3 %) were musculotendinous injuries, with 9 cases (16.4 %) in the medial aponeurosis (MMT), 11 cases (20 %) in the lateral aponeurosis (LMT), and 11 cases (20 %) in the central tendon (CMT). In comparison to MRI, ultrasound was able to detect injury to the soleus in 27.2 % of cases. No injuries were detected by ultrasound alone. Posterior myofascial injuries were more likely to be detected by ultrasound than anterior myofascial injuries or all types of musculotendinous injuries. Ultrasound patterns for each type of injury were described. Ultrasound is not a sensitive technique for detecting and assessing soleus traumatic tears compared with MRI, although the sensitivity is enhanced by a thorough anatomically based ultrasound examination. Timing of the ultrasound examination may be of importance. Each type of soleus injury appears to have a characteristic ultrasound pattern based on a defect of connective expansions, the existence of small myofascial filiform collections, and the rarefaction of the fibrillar area. (orig.)

  20. Soleus muscle injury: sensitivity of ultrasound patterns.

    Science.gov (United States)

    Balius, Ramon; Rodas, Gil; Pedret, Carles; Capdevila, Lluís; Alomar, Xavier; Bong, David A

    2014-06-01

    To assess the sensitivity of ultrasound in detecting soleus muscle lesions diagnosed on magnetic resonance imaging (MRI) and to characterize their location, ultrasound pattern, and evolution. Ultrasound and MRI studies were performed between May 2009 and February 2013 on all patients who presented to the Medical Services Clinic of the Catalan Sport Council with the initial onset of sharp pain in the calf compatible with injury of the soleus muscle. An inter-observer ultrasound reliability study was also performed. A total of 55 cases of soleus injury were studied prospectively (22 with right leg involvement, 33 left) by ultrasound and MRI, which was utilized as the "gold standard." In MRI studies, 24 cases (43.7%) had myofascial injuries that were localized in the posterior aponeurosis (PMF) in 15 cases (27.3%) and in the anterior aponeurosis (AMF) in 9 (16.4%). Thirty-one cases (56.3%) were musculotendinous injuries, with 9 cases (16.4%) in the medial aponeurosis (MMT), 11 cases (20%) in the lateral aponeurosis (LMT), and 11 cases (20%) in the central tendon (CMT). In comparison to MRI, ultrasound was able to detect injury to the soleus in 27.2% of cases. No injuries were detected by ultrasound alone. Posterior myofascial injuries were more likely to be detected by ultrasound than anterior myofascial injuries or all types of musculotendinous injuries. Ultrasound patterns for each type of injury were described. Ultrasound is not a sensitive technique for detecting and assessing soleus traumatic tears compared with MRI, although the sensitivity is enhanced by a thorough anatomically based ultrasound examination. Timing of the ultrasound examination may be of importance. Each type of soleus injury appears to have a characteristic ultrasound pattern based on a defect of connective expansions, the existence of small myofascial filiform collections, and the rarefaction of the fibrillar area.

  1. Soleus muscle injury: sensitivity of ultrasound patterns

    International Nuclear Information System (INIS)

    Balius, Ramon; Rodas, Gil; Pedret, Carles; Capdevila, Lluis; Alomar, Xavier; Bong, David A.

    2014-01-01

    To assess the sensitivity of ultrasound in detecting soleus muscle lesions diagnosed on magnetic resonance imaging (MRI) and to characterize their location, ultrasound pattern, and evolution. Ultrasound and MRI studies were performed between May 2009 and February 2013 on all patients who presented to the Medical Services Clinic of the Catalan Sport Council with the initial onset of sharp pain in the calf compatible with injury of the soleus muscle. An inter-observer ultrasound reliability study was also performed. A total of 55 cases of soleus injury were studied prospectively (22 with right leg involvement, 33 left) by ultrasound and MRI, which was utilized as the ''gold standard.'' In MRI studies, 24 cases (43.7 %) had myofascial injuries that were localized in the posterior aponeurosis (PMF) in 15 cases (27.3 %) and in the anterior aponeurosis (AMF) in 9 (16.4 %). Thirty-one cases (56.3 %) were musculotendinous injuries, with 9 cases (16.4 %) in the medial aponeurosis (MMT), 11 cases (20 %) in the lateral aponeurosis (LMT), and 11 cases (20 %) in the central tendon (CMT). In comparison to MRI, ultrasound was able to detect injury to the soleus in 27.2 % of cases. No injuries were detected by ultrasound alone. Posterior myofascial injuries were more likely to be detected by ultrasound than anterior myofascial injuries or all types of musculotendinous injuries. Ultrasound patterns for each type of injury were described. Ultrasound is not a sensitive technique for detecting and assessing soleus traumatic tears compared with MRI, although the sensitivity is enhanced by a thorough anatomically based ultrasound examination. Timing of the ultrasound examination may be of importance. Each type of soleus injury appears to have a characteristic ultrasound pattern based on a defect of connective expansions, the existence of small myofascial filiform collections, and the rarefaction of the fibrillar area. (orig.)

  2. The value of intraoperative ultrasound (IUS) examination for the visualization of metastatic cerebral lesions, compared with computed tomography (CT) and magnetic resonance (MRI)

    International Nuclear Information System (INIS)

    Tacikowska, M.; Szczerbicki, M.; Grzesiakowska, U.

    2001-01-01

    The purpose of this study is: 1. to assess the value of intraoperative ultrasonographic examination (IUSG) in confirming intraoperatively the presence of metastatic tumours detected preoperatively by computed tomography (CT) and magnetic resonance tomography (MRI), 2. to evaluate an accordance of the numbers, localization and dimensions of metastatic tumours recognized preoperatively (CT and MRI) with those shown by intraoperative USG, 3. to comparatively assess the images of metastatic tumours found in preoperative CT and MRI examinations and in intraoperative USG examinations. Sixteen patients were operated upon for metastatic intracranial tumours from various primary foci. All patients had diagnostic brain examinations before the operation: MRI and CT in 7 cases, only MRI in 3 cases, only CT in 6 cases. Intraoperative USG examination was done in all cases. Retrospective analysis included: 1. comparative assessment of the images of metastatic tumours in intraoperative USG versus preoperative MRI and CT findings, 2. analysis of the number, localization and dimensions of metastatic tumours detected preoperatively and in intraoperative USG examination. The comparison of the greatest dimensions of metastatic lesions measured in CT and MRI findings, and in intraoperative USG based on Student t test showed no statistically significant differences between the examinations performed, p=0.2449. No statistically significant difference were found either between the numbers of metastatic lesions detected by these methods, p=0.71830. In the analysis of the images of metastatic lesions in preoperative examinations, the non--homogenous foci with margin enhancement after administration of gadolinium or contrast medium, with inner area not enhanced (necrosis?) were found in 8 cases (10 foci lesions), and in USG in 6 cases (9 focal lesions). In one case (one lesion) USG showed that the tumour was hypo echogenic as a whole, without areola around it. Intraoperative USG examination

  3. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... ultrasound. top of page How does the procedure work? Ultrasound imaging is based on the same principles ... modality for the diagnosis and monitoring of pregnant women and their unborn babies. Ultrasound provides real-time ...

  4. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... medical test that helps physicians diagnose and treat medical conditions. Conventional ultrasound displays the images in thin, flat sections of the body. Advancements in ultrasound technology include three-dimensional (3-D) ultrasound that formats ...

  5. Ultrasound guided supraclavicular block.

    LENUS (Irish Health Repository)

    Hanumanthaiah, Deepak

    2013-09-01

    Ultrasound guided regional anaesthesia is becoming increasingly popular. The supraclavicular block has been transformed by ultrasound guidance into a potentially safe superficial block. We reviewed the techniques of performing supraclavicular block with special focus on ultrasound guidance.

  6. Vacuum mammotomy under ultrasound guidance

    International Nuclear Information System (INIS)

    Luczynska, E.; Kocurek, A.; Pawlik, T.; Aniol, J.; Herman, K.; Skotnicki, P.

    2007-01-01

    Breast ultrasound is a non-invasive method of breast examination. You can use it also for fine needle biopsy, core needle biopsy, vacuum mammotomy and for placing the '' wire '' before open surgical biopsy. 106 patients (105 women and 1 man) aged 20-71 years (mean age 46.9) were treated in Cancer Institute in Cracow by vacuum mammotomy under ultrasound guidance. The lesions found in ultrasonography were divided into three groups: benign lesions (BI RADS II), ambiguous lesions (BI RADS 0, III and IVa), and suspicious lesions (BI RADS IV B, IV C and V). Then lesions were qualified to vacuum mammotomy. According to USG, fibroadenoma or '' fibroadenoma-like '' lesions were found in 75 women, in 6 women complicated cysts, in 6 women cyst with dense fluid (to differentiate with FA), and in 19 patients undefined lesions. Fibroadenoma was confirmed in histopathology in 74% patients among patients with fibroadenoma or '' fibroadenoma-like '' lesions in ultrasound (in others also benign lesions were found). Among lesions undefined after ultrasound examination (total 27 patients) cancer was confirmed in 6 % (DCIS and IDC). In 6 patients with complicated cysts in ultrasound examination, histopathology confirmed fibroadenoma in 4 women, an intraductal lesion in 1 woman and inflamatory process in 1 woman. Also in 6 women with a dense cyst or fibroadenoma seen in ultrasound, histopathology confirmed fibroadenoma in 3 women and fibrosclerosis in 3 women. Any breast lesions undefined or suspicious after ultrasound examination should be verified. The method of verification or kind of operation of the whole lesion (vacuum mammotomy or '' wire '') depends on many factors, for example: lesion localization; lesion size; BI RADS category. (author)

  7. Core review: physician-performed ultrasound: the time has come for routine use in acute care medicine.

    Science.gov (United States)

    Royse, Colin F; Canty, David J; Faris, John; Haji, Darsim L; Veltman, Michael; Royse, Alistair

    2012-11-01

    The use of ultrasound in the acute care specialties of anesthesiology, intensive care, emergency medicine, and surgery has evolved from discrete, office-based echocardiographic examinations to the real-time or point-of-care clinical assessment and interventions. "Goal-focused" transthoracic echocardiography is a limited scope (as compared with comprehensive examination) echocardiographic examination, performed by the treating clinician in acute care medical practice, and is aimed at addressing specific clinical concerns. In the future, the practice of surface ultrasound will be integrated into the everyday clinical practice as ultrasound-assisted examination and ultrasound-guided procedures. This evolution should start at the medical student level and be reinforced throughout specialist training. The key to making ultrasound available to every physician is through education programs designed to facilitate uptake, rather than to prevent access to this technology and education by specialist craft groups. There is evidence that diagnosis is improved with ultrasound examination, yet data showing change in management and improvement in patient outcome are few and an important area for future research.

  8. [Diagnostic ultrasound in pneumothorax].

    Science.gov (United States)

    Maury, É; Pichereau, C; Bourcier, S; Galbois, A; Lejour, G; Baudel, J-L; Ait-Oufella, H; Guidet, B

    2016-10-01

    For a long time the lung has been regarded as inaccessible to ultrasound. However, recent clinical studies have shown that this organ can be examined by this technique, which appears, in some situations, to be superior to thoracic radiography. The examination does not require special equipment and is possible using a combination of simple qualitative signs: lung sliding, the presence of B lines and the demonstration of the lung point. The lung sliding corresponds to the artefact produced by the movement of the two pleural layers, one against the other. The B lines indicate the presence of an interstitial syndrome. The presence of lung sliding and/or B lines has a negative predictive value of 100% and formally excludes a pneumothorax in the area where the probe has been applied. The presence of the lung point is pathognomonic of pneumothorax but the sensitivity is no more than 60%. Ultrasound is therefore a rapid and simple means of excluding a pneumothorax (lung sliding or B lines) and of confirming a pneumothorax when the lung point is visible. The question that remains is whether ultrasound can totally replace radiography in the management of this disorder. Copyright © 2015 SPLF. Published by Elsevier Masson SAS. All rights reserved.

  9. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... through blood vessels. Ultrasound imaging is a noninvasive medical test that helps physicians diagnose and treat medical conditions. Conventional ultrasound displays the images in thin, ...

  10. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... and treat medical conditions. Conventional ultrasound displays the images in thin, flat sections of the body. Advancements in ultrasound technology include three-dimensional (3- ...

  11. The Development of a Cultural-Based Educational Program to Enhance Breast Self-Examination (BSE Self-Efficacy

    Directory of Open Access Journals (Sweden)

    Juanita Juanita

    2012-08-01

    Full Text Available Purpose: To develop the educational program which is appropriate with Islamic culture in order to enhance BSE self-efficacy of nursing students and thus promote BSE practice. Method: This study is a development research study which is consisting of three phases including: 1 reviewing several existing BSE educational programs; 2 program design based on SCT and Islamic culture; and 3 program validation by three experts. Result: Based on previous studies, the most appropriate theory to enhance self-efficacy was Social Cognitive Theory (SCT because this theory provides several strategies to increase the self-efficacy. Further, the program that used Islamic culture was more appropriate to increase BSE practice among Muslim women. As a result, the newly developed program was developed used SCT and Islamic culture. This program was comprised of four sessions including: 1 exploring Islamic mandate on prevention and individual responsibility in health promotion, and culture-related beliefs toward BSE, 2 health education by conducting lecturing session and watching a video about BSE procedures, 3 BSE training activities including BSE demonstration and return demonstration, 4 follow-up by conducting a meeting. Conclusion: The cultural-based educational program for enhancing BSE self-efficacy and promoting BSE is a program using multifaceted methods. It designed based on a review of the literature from previous studies and were supported by research findings on experimental studies in other population. Keywords: Cultural, Educational program development, Breast self-examination, Self-efficacy.

  12. Systems theory as a framework for examining a college campus-based support program for the former foster youth.

    Science.gov (United States)

    Schelbe, Lisa; Randolph, Karen A; Yelick, Anna; Cheatham, Leah P; Groton, Danielle B

    2018-01-01

    Increased attention to former foster youth pursuing post-secondary education has resulted in the creation of college campus based support programs to address their need. However, limited empirical evidence and theoretical knowledge exist about these programs. This study seeks to describe the application of systems theory as a framework for examining a college campus based support program for former foster youth. In-depth semi-structured interviews were conducted with 32 program stakeholders including students, mentors, collaborative members, and independent living program staff. Using qualitative data analysis software, holistic coding techniques were employed to analyze interview transcripts. Then applying principles of extended case method using systems theory, data were analyzed. Findings suggest systems theory serves as a framework for understanding the functioning of a college campus based support program. The theory's concepts help delineate program components and roles of stakeholders; outline boundaries between and interactions among stakeholders; and identify program strengths and weakness. Systems theory plays an important role in identifying intervention components and providing a structure through which to identify and understand program elements as a part of the planning process. This study highlights the utility of systems theory as a framework for program planning and evaluation.

  13. The Influence of Using TI-84 Calculators with Programs on Algebra I High Stakes Examinations

    Science.gov (United States)

    Spencer, Misty

    2013-01-01

    The purpose of this study was to determine if there was a significant difference in scores on the Mississippi Algebra I SATP2 when one group was allowed to use programs and the other group was not allowed to use programs on TI-84 calculators. An additional purpose of the study was also to determine if there was a significant difference in the…

  14. Does Teaching Experience Matter? Examining Biology Teachers' Prior Knowledge for Teaching in an Alternative Certification Program

    Science.gov (United States)

    Friedrichsen, Patricia J.; Abell, Sandra K.; Pareja, Enrique M.; Brown, Patrick L.; Lankford, Deanna M.; Volkmann, Mark J.

    2009-01-01

    Alternative certification programs (ACPs) have been proposed as a viable way to address teacher shortages, yet we know little about how teacher knowledge develops within such programs. The purpose of this study was to investigate prior knowledge for teaching among students entering an ACP, comparing individuals with teaching experience to those…

  15. Recruitment Strategies Aiming to Attract Females into Undergraduate Engineering Programs: Examining Their Role and Use

    Science.gov (United States)

    Howenstine, Julie Anne

    2013-01-01

    By 2009, the percentage of women who graduated with general undergraduate degrees had increased to almost 58% of all students who completed 4-year degree programs (National Center for Education Statistics, 2009a). These percentages, however, have not been reflected in the enrollment rates of females into undergraduate engineering programs. In…

  16. An Examination of the Feasibility of Integrating Motivational Interviewing Techniques into FCS Cooperative Extension Programming

    Science.gov (United States)

    Radunovich, Heidi Liss; Ellis, Sarah; Spangler, Taylor

    2017-01-01

    Demonstrating program impact through behavior change is critical for the continued success of Family and Consumer Sciences (FCS) Cooperative Extension programming. However, the literature suggests that simply providing information to participants does not necessarily lead to behavior change. This study pilot tested the integration of Motivational…

  17. A Study Examining the Dimensionality of Core Competencies Measure in Teacher Preparation Programs: Challenges and Lessons

    Science.gov (United States)

    Kizil, Ruhan Circi; Briggs, Derek; Seidel, Kent; Green, Kathy

    2014-01-01

    The evidence that teacher preparation programs have an impact on teacher quality is often limited. Progress in research on this topic will remain rather limited in its influence on practice until more proximal measures of teacher education outcomes can be established. The dearth of variables to measure the impact of teacher preparation programs on…

  18. Examining quality of contraceptive services for adolescents in Oregon's family planning program.

    Science.gov (United States)

    Rodriguez, Maria Isabel; Darney, Blair G; Elman, Emily; Linz, Rachel; Caughey, Aaron B; McConnell, K John

    2015-04-01

    To assess the quality of care provided to adolescents (10-19 years old) compared to women (aged 20-25 years) who accessed services in Oregon's Contraceptive Care (CCare) program. We analyzed data routinely collected using the Clinic Visit Record form from women aged 25 years and younger who visited CCare clinics between January 1, 2004, and October 31, 2010. Modern methods were characterized into three tiers: Tier 1 is the intrauterine device, implant and sterilization; Tier 2, hormonal methods; and Tier 3, all barrier methods. Nonmodern methods included no method, withdrawal and natural family planning. We used multivariable logistic regression models to examine the effect of age on three indicators of quality of contraceptive care: transitioning from a nonmodern to a modern method, transitioning from Tier 3 methods to Tier 1 or Tier 2 methods, and initiation of long-acting reversible contraception (LARC). We then produced predicted probabilities to facilitate data interpretation. Adolescents accounted for 344,856 (41%) of the 848,221 clinic visits occurring in CCare among women under age 25. Compared with women (ages 20-25 years), young and older adolescents had decreased odds of LARC initiation [odds ratio (OR) 0.24 (95% confidence interval [CI] 0.16-0.35) and OR 0.44 (95% CI 0.38-0.52), respectively]. However, compared with women, both young and older adolescents had increased odds of leaving with any contraceptive method [OR 1.8 95% (CI 1.26-2.59) and OR 1.42 (95% CI 1.21-1.66)]. Among clients presenting with no method of contraception at the beginning of the visit, 78.7% of young adolescents (95% CI 73.84-83.03) compared with 81.44% (95% CI 77.02-85.52) of older adolescents, and 76.63% (95% CI 69.90-80.75) of young women left with a modern method, controlling for other covariates. Although adolescents served by CCare are more likely to initiate contraception, they are less likely to receive LARC than women aged 20-25 years. Efforts are needed to ensure that

  19. Using the baseline environmental management report (BEMR) to examine alternate program scenarios

    International Nuclear Information System (INIS)

    Kristofferson, K.

    1995-01-01

    The US Department of Energy's (DOE) Office of Environmental Management (EM) released the first Baseline Environmental Management Report (BEMR) in March, 1995. The Congressionally-mandated report provides life-cycle cost estimates, tentative schedules, and projected activities necessary to complete DOE's Environmental Management Program. This ''base case'' estimate is based on current program assumptions and the most likely set of activities. However, since the future course of the Environmental Management Program depends upon a number of fundamental technical and policy choices, alternate program scenarios were developed. These alternate cases show the potential cost impacts of changing assumptions in four key areas: future land use, program funding and scheduling, technology development, and waste management configurations. Several cost and program evaluation tools were developed to support the analysis of these alternate cases. The objective of this paper is to describe the analytical tool kit developed to support the development of the 1995 Baseline Report and to discuss the application of these tools to evaluate alternate program scenarios

  20. An Examination of Georgia Young Farmer Program Participants’ Learning Style Preferences

    Directory of Open Access Journals (Sweden)

    Barry S. Bailey

    2017-10-01

    Full Text Available This study was designed to describe Georgia Young Farmer Program participants’ learning style preferences. Using survey research methods, a questionnaire was designed to collect data related to the purpose of the study. The population for this study included active members in the program. Study findings showed that participants had a preference for kinesthetic learning over visual and auditory learning. While participants indicated a preference for kinesthetic learning, all three learning styles were deemed effective. Preferences for learning styles and perception of effectiveness did not differ by personal characteristics. Recommendations include taking learning style preferences into account when designing and delivering programming, training for teachers, and continuing to assess learners’ preferences.

  1. Examining the Effectiveness of the Smoking Prevention Program "I Do Not Smoke, I Exercise" in Elementary and Secondary School Settings.

    Science.gov (United States)

    Kolovelonis, Athanasios; Goudas, Marios; Theodorakis, Yannis

    2016-11-01

    The aim of the study was to examine the effectiveness of the smoking prevention program "I do not smoke, I exercise" implemented with elementary and secondary school students. "I do not smoke, I exercise" is a theory-based smoking prevention program that promotes exercise as an alternative of smoking. The program consists of eight sessions implemented weekly. Participants were 338 Greek students (135 elementary and 203 secondary students) who were pre- and posttested in smoking, program, and exercise-related measures. The results showed that the program had significant effects on elementary students' attitudes toward smoking, intention to smoke, subjective norms, attitudes toward the application of the program, and knowledge about the health consequences of smoking. For secondary students, significant effects were found on students' perceived behavioral control and knowledge about the health consequences of smoking, while very few students reported a smoking experience before and after the intervention. Therefore the program "I do not smoke, I exercise" may have positive effects on variables related with smoking behavior. Differences in the program's impact on elementary and secondary students were identified. All these are discussed with reference to the need of implementing smoking prevention programs in schools contexts. © 2016 Society for Public Health Education.

  2. An examination of factors that hinder and programs that stimulate Papuan entrepreneurs

    NARCIS (Netherlands)

    Burg, van J.C.

    2007-01-01

    This report describes the results of a study on entrepreneurship in the Indonesian province Papua. The study was performed for Oikonomos Foundation to help evaluating the current entrepreneurship support programs and to identify future challenges. Seven important difficulties for Papuan

  3. Ultrasound in the Assessment of Myopathic Disorders

    NARCIS (Netherlands)

    Zaidman, C.M.; Alfen, N. van

    2016-01-01

    Neuromuscular ultrasound (US) augments a careful physical examination and electrodiagnostic evaluation in the evaluation of suspected myopathy. Ultrasound evaluation of muscle can identify abnormal echo intensity, size, and movement. Because it is painless and noninvasive, US can be used to evaluate

  4. Examining the Leisure Constraints Affecting International Collegiate Students’ Participation in Intramural Sport Programs

    OpenAIRE

    Dongwook Cho; Taryn Price

    2016-01-01

    A primary objective of United States’ higher education institutions is the production of well-balanced citizens. Aside from awarded degrees, other primary offerings include leisure opportunities, from campus recreation programs. Campus recreation through intramural sport programs offers students an opportunity to participate in sport and physical fitness activities on campus with and against other collegiate students. Recognizing the continuous increase in collegiate enrollment of internation...

  5. A theoretical study of cylindrical ultrasound transducers for intracavitary hyperthermia

    International Nuclear Information System (INIS)

    Lin, W.-L.; Fan, W.-C.; Yen, J.-Y.; Chen, Y.-Y.; Shieh, M.-J.

    2000-01-01

    Purpose: The purpose of this paper was to examine the heating patterns and penetration depth when a cylindrical ultrasound transducer is employed for intracavitary hyperthermia treatments. Methods and Materials: The present study employs a simulation program based on a simplified power deposition model for infinitely long cylindrical ultrasound transducers. The ultrasound power in the tissue is assumed to be exponentially attenuated according to the penetration depth of the ultrasound beam, and a uniform attenuation for the entire treatment region is also assumed. The distribution of specific absorption rate (SAR) ratio (the ratio of SAR for a point within the tissue to that for a specific point on the cavity surface) is used to determine the heating pattern for a set of given parameters. The parameters considered are the ultrasound attenuation in the tissue, the cavity size, and the transducer eccentricity. Results: Simulation results show that the ultrasound attenuation in the tissue, the cavity size, and the transducer eccentricity are the most influential parameters for the distribution of SAR ratio. A low frequency transducer located in a large cavity can produce a much better penetration. The cavity size is the major parameter affecting the penetration depth for a small cavity size, such as interstitial hyperthermia. The heating pattern can also be dramatically changed by the transducer eccentricity and radiating sector. In addition, for a finite length of cylindrical transducer, lower SAR ratio appears in the regions near the applicator's edges. Conclusion: The distribution of SAR ratio indicates the relationship between the treatable region and the parameters if an appropriate threshold of SAR ratio is taken. The findings of the present study comprehend whether or not a tumor is treatable, as well as select the optimal driving frequency, the appropriate cavity size, and the eccentricity of a cylindrical transducer for a specific treatment

  6. Comparison of Photo Optical Imaging with Musculoskeletal Ultrasound and Clinical Examination in the Assessment of Inflammatory Activity in Proximal Interphalangeal Joints in Rheumatoid Arthritis and Osteoarthritis.

    Science.gov (United States)

    Amitai, Isabella; Werner, Stephanie; Schicke, Bernd; Burmester, Gerd-Rüdiger; Minet, Olaf; Zabaryło, Urszula; Backhaus, Marina; Ohrndorf, Sarah

    2015-09-01

    Lightscan is a novel, rapid, low-cost, easily operated and noninvasive imaging technology used to assess inflammatory activity in proximal interphalangeal (PIP) joints. The results are calculated automatically. To our knowledge, this is the first comparative study of photo optical imaging (POI), with clinical examination (CE), disease activity score at 28 joints (DAS28)-erythrocyte sedimentation rate (ESR), and musculoskeletal ultrasonography (US) in healthy subjects and patients with rheumatoid arthritis (RA) or osteoarthritis (OA). There were 688 PIP joints of both hands examined in 87 subjects (38 RA, 21 OA, 28 healthy) by Lightscan and compared with CE for clinically swollen and tender joints, DAS28-ESR (only RA), and US. With US as reference, POI had a sensitivity of 74% and a specificity of 93%. In the receiver-operating curve (ROC) analysis, the Lightscan showed a higher sensitivity and specificity [area under the curve (AUC) 0.879] for the distinction of healthy subjects versus patients (OA, RA) than US in greyscale (GSUS; AUC 0.797) and power Doppler (PDUS; AUC 0.67). POI correlated significantly with GSUS (r 0.473, p POI and GSUS were up to 79%, between POI and PDUS up to 92%, and between POI and CE up to 66%. POI did not correlate with DAS28-ESR. The Lightscan is a new technology offering sensitive imaging detection of inflammatory changes in subjects with RA and OA with PIP arthritis. POI was more sensitive than CE and correlated significantly to GSUS and PDUS, while presenting a higher sensitivity and specificity for the detection of healthy subjects versus patients (RA, OA) based on the ROC analysis.

  7. Development of Web-Based Examination System Using Open Source Programming Model

    Science.gov (United States)

    Abass, Olalere A.; Olajide, Samuel A.; Samuel, Babafemi O.

    2017-01-01

    The traditional method of assessment (examination) is often characterized by examination questions leakages, human errors during marking of scripts and recording of scores. The technological advancement in the field of computer science has necessitated the need for computer usage in majorly all areas of human life and endeavors, education sector…

  8. Preventing child maltreatment: Examination of an established statewide home-visiting program.

    Science.gov (United States)

    Chaiyachati, Barbara H; Gaither, Julie R; Hughes, Marcia; Foley-Schain, Karen; Leventhal, John M

    2018-05-01

    Although home visiting has been used in many populations in prevention efforts, the impact of scaled-up home-visiting programs on abuse and neglect remains unclear. The objective of this study was to assess the impact of voluntary participation in an established statewide home-visiting program for socially high-risk families on child maltreatment as identified by Child Protective Services (CPS). Propensity score matching was used to compare socially high-risk families with a child born between January 1, 2008 and December 31, 2011 who participated in Connecticut's home-visiting program for first-time mothers and a comparison cohort of families who were eligible for the home-visiting program but did not participate. The main outcomes were child maltreatment investigations, substantiations, and out-of-home placements by CPS between January 1, 2008 and December 31, 2013. In the unmatched sample, families who participated in home-visiting had significantly higher median risk scores (P home visiting. First substantiations also occurred later in the child's life among home-visited families. There was a trend toward decreased out-of-home placement (HR 0.73, 95% CI 0.53-1.02, P = .06). These results from a scaled-up statewide program highlight the potential of home visiting as an important approach to preventing child abuse and neglect. Copyright © 2018 Elsevier Ltd. All rights reserved.

  9. Ultrasound of the acute abdomen performed by surgeons in training

    DEFF Research Database (Denmark)

    Eiberg, J.P.; Grantcharov, T.P.; Eriksen, J.R.

    2008-01-01

    , specificity and kappa-agreement of the surgeon performed ultrasound examination was 1.00 (0.77-1.00), 0.96 (0.79-0.99), 0.94 (0.3-1.00) and 0.40 (0.12-0.77), 0.97 (0.83-0.99), 0.44 (0.00-0.96); respectively. Visualization of the common bile duct was poor having 73% non-diagnostic surgeon-performed ultrasound...... perform valid abdominal ultrasound examinations of patients referred with acute abdominal pain. METHODS: Patients referred with acute abdominal pain had an ultrasound examination by a surgeon in training as well as by an experienced consultant radiologist whose results served as the gold standard. All...... participating surgeons were without any pre-existing ultrasound experience and received one hour of introduction to abdominal ultrasound. RESULTS: Thirty patients underwent 40 surgeon performed and 30 radiologist performed ultrasound examinations. Regarding gallstone and cholecholecystitis the sensitivity...

  10. Diagnostic Accuracy of History, Physical Examination, Laboratory Tests, and Point-of-care Ultrasound for Pediatric Acute Appendicitis in the Emergency Department: A Systematic Review and Meta-analysis.

    Science.gov (United States)

    Benabbas, Roshanak; Hanna, Mark; Shah, Jay; Sinert, Richard

    2017-05-01

    Acute appendicitis (AA) is the most common surgical emergency in children. Accurate and timely diagnosis is crucial but challenging due to atypical presentations and the inherent difficulty of obtaining a reliable history and physical examination in younger children. The aim of this study was to determine the utility of history, physical examination, laboratory tests, Pediatric Appendicitis Score (PAS) and Emergency Department Point-of-Care Ultrasound (ED-POCUS) in the diagnosis of AA in ED pediatric patients. We performed a systematic review and meta-analysis and used a test-treatment threshold model to identify diagnostic findings that could rule in/out AA and obviate the need for further imaging studies, specifically computed tomography (CT) scan, magnetic resonance imaging (MRI), and radiology department ultrasound (RUS). We searched PubMed, EMBASE, and SCOPUS up to October 2016 for studies on ED pediatric patients with abdominal pain. Quality Assessment Tool for Diagnostic Accuracy Studies (QUADAS-2) was used to evaluate the quality and applicability of included studies. Positive and negative likelihood ratios (LR+ and LR-) for diagnostic modalities were calculated and when appropriate data was pooled using Meta-DiSc. Based on the available literature on the test characteristics of different imaging modalities and applying the Pauker-Kassirer method we developed a test-treatment threshold model. Twenty-one studies were included encompassing 8,605 patients with weighted AA prevalence of 39.2%. Studies had variable quality using the QUADAS-2 tool with most studies at high risk of partial verification bias. We divided studies based on their inclusion criteria into two groups of "undifferentiated abdominal pain" and abdominal pain "suspected of AA." In patients with undifferentiated abdominal pain, history of "pain migration to right lower quadrant (RLQ)" (LR+ = 4.81, 95% confidence interval [CI] = 3.59-6.44) and presence of "cough/hop pain" in the physical

  11. DEVELOPMENT OF WEB-BASED EXAMINATION SYSTEM USING OPEN SOURCE PROGRAMMING MODEL

    Directory of Open Access Journals (Sweden)

    Olalere A. ABASS

    2017-04-01

    Full Text Available The traditional method of assessment (examination is often characterized by examination questions leakages, human errors during marking of scripts and recording of scores. The technological advancement in the field of computer science has necessitated the need for computer usage in majorly all areas of human life and endeavors, education sector not excluded. This work, Web-based Examination System (WES was, therefore, born out of the will to stymie the problems plaguing the conventional (paper-based examination system by providing a campus-wide service for e-assessment devoid of irregularities and generally fair to examinees and equally enhances instant feedback. This system developed using combination of CSS, HTML, PHP SQL MySQL and Dreamweaver is capable of reducing proportion of workload on examination, grading and reviewing on the part of examiners. Thus, the system enables the release of examination results in record time and without error. WES can serve as an effective solution for mass education evaluation and offers many novel features that cannot be implemented in paper-based systems, such as real time data collection, management and analysis, distributed and interactive assessment towards promoting distance education.

  12. Examinations on Applications of Manual Calculation Programs on Lung Cancer Radiation Therapy Using Analytical Anisotropic Algorithm

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Jung Min; Kim, Dae Sup; Hong, Dong Ki; Back, Geum Mun; Kwak, Jung Won [Dept. of Radiation Oncology, , Seoul (Korea, Republic of)

    2012-03-15

    There was a problem with using MU verification programs for the reasons that there were errors of MU when using MU verification programs based on Pencil Beam Convolution (PBC) Algorithm with radiation treatment plans around lung using Analytical Anisotropic Algorithm (AAA). On this study, we studied the methods that can verify the calculated treatment plans using AAA. Using Eclipse treatment planning system (Version 8.9, Varian, USA), for each 57 fields of 7 cases of Lung Stereotactic Body Radiation Therapy (SBRT), we have calculated using PBC and AAA with dose calculation algorithm. By developing MU of established plans, we compared and analyzed with MU of manual calculation programs. We have analyzed relationship between errors and 4 variables such as field size, lung path distance of radiation, Tumor path distance of radiation, effective depth that can affect on errors created from PBC algorithm and AAA using commonly used programs. Errors of PBC algorithm have showned 0.2{+-}1.0% and errors of AAA have showned 3.5{+-}2.8%. Moreover, as a result of analyzing 4 variables that can affect on errors, relationship in errors between lung path distance and MU, connection coefficient 0.648 (P=0.000) has been increased and we could calculate MU correction factor that is A.E=L.P 0.00903+0.02048 and as a result of replying for manual calculation program, errors of 3.5{+-}2.8% before the application has been decreased within 0.4{+-}2.0%. On this study, we have learned that errors from manual calculation program have been increased as lung path distance of radiation increases and we could verified MU of AAA with a simple method that is called MU correction factor.

  13. Examinations on Applications of Manual Calculation Programs on Lung Cancer Radiation Therapy Using Analytical Anisotropic Algorithm

    International Nuclear Information System (INIS)

    Kim, Jung Min; Kim, Dae Sup; Hong, Dong Ki; Back, Geum Mun; Kwak, Jung Won

    2012-01-01

    There was a problem with using MU verification programs for the reasons that there were errors of MU when using MU verification programs based on Pencil Beam Convolution (PBC) Algorithm with radiation treatment plans around lung using Analytical Anisotropic Algorithm (AAA). On this study, we studied the methods that can verify the calculated treatment plans using AAA. Using Eclipse treatment planning system (Version 8.9, Varian, USA), for each 57 fields of 7 cases of Lung Stereotactic Body Radiation Therapy (SBRT), we have calculated using PBC and AAA with dose calculation algorithm. By developing MU of established plans, we compared and analyzed with MU of manual calculation programs. We have analyzed relationship between errors and 4 variables such as field size, lung path distance of radiation, Tumor path distance of radiation, effective depth that can affect on errors created from PBC algorithm and AAA using commonly used programs. Errors of PBC algorithm have showned 0.2±1.0% and errors of AAA have showned 3.5±2.8%. Moreover, as a result of analyzing 4 variables that can affect on errors, relationship in errors between lung path distance and MU, connection coefficient 0.648 (P=0.000) has been increased and we could calculate MU correction factor that is A.E=L.P 0.00903+0.02048 and as a result of replying for manual calculation program, errors of 3.5±2.8% before the application has been decreased within 0.4±2.0%. On this study, we have learned that errors from manual calculation program have been increased as lung path distance of radiation increases and we could verified MU of AAA with a simple method that is called MU correction factor.

  14. Head Start Program Quality: Examination of Classroom Quality and Parent Involvement in Predicting Children's Vocabulary, Literacy, and Mathematics Achievement Trajectories

    Science.gov (United States)

    Wen, Xiaoli; Bulotsky-Shearer, Rebecca J.; Hahs-Vaughn, Debbie L.; Korfmacher, Jon

    2012-01-01

    Guided by a developmental-ecological framework and Head Start's two-generational approach, this study examined two dimensions of Head Start program quality, classroom quality and parent involvement and their unique and interactive contribution to children's vocabulary, literacy, and mathematics skills growth from the beginning of Head Start…

  15. Examination of Sign Language Education According to the Opinions of Members from a Basic Sign Language Certification Program

    Science.gov (United States)

    Akmese, Pelin Pistav

    2016-01-01

    Being hearing impaired limits one's ability to communicate in that it affects all areas of development, particularly speech. One of the methods the hearing impaired use to communicate is sign language. This study, a descriptive study, intends to examine the opinions of individuals who had enrolled in a sign language certification program by using…

  16. 46 CFR 71.50-17 - Eligibility requirements for the Alternative Hull Examination (AHE) Program for certain passenger...

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 3 2010-10-01 2010-10-01 false Eligibility requirements for the Alternative Hull...-17 Eligibility requirements for the Alternative Hull Examination (AHE) Program for certain passenger... aluminum; (2) It has an effective hull protection system; (3) It has operated exclusively in fresh water...

  17. Examining the Permanence of the Effect of an Empathy Program for the Acquisition of Empathy Skills on Gifted Adolescents

    Science.gov (United States)

    Nedim Bal, Pervin

    2015-01-01

    This study aimed to examine the permanence of the effect of an Empathy Training Program, administered 8 months ago on gifted adolescents studying in 6th and 7th grades. The sample of this study consisted of 60 students with IQ scores of above 130 and studied in Enderun Gifted Children Center. Bryant's Empathy Scale for Children was administered to…

  18. An Examination of Mental Health Content in Course Work and Field Experiences in Connecticut Educational Leadership Preparation Programs

    Science.gov (United States)

    Papa, Dorothy P.

    2017-01-01

    This exploratory mixed method convergent parallel study examined Connecticut Educational leadership preparation programs for the existence of mental health content to learn the extent to which pre-service school leaders are prepared for addressing student mental health. Interviews were conducted with school mental health experts and Connecticut…

  19. Examining Intercultural Growth for Business Students in Short-Term Study Abroad Programs: Too Good to Be True?

    Science.gov (United States)

    Gullekson, Nicole L.; Tucker, Mary L.; Coombs, Garth, Jr.; Wright, Scott B.

    2011-01-01

    Changes in ethnocentrism, intercultural communication apprehension, international awareness and activities were examined in business students participating in a 16-day consulting program abroad and compared to a control group of students at the home university. Anticipated changes in the study abroad students were found; however, when compared to…

  20. Set up for Success: An Examination of the Ronald E. McNair Postbaccalaureate Achievement Program's Mentoring Component

    Science.gov (United States)

    Wyre, Dwuena Cene

    2011-01-01

    Often, individuals are set up to fail. However, effective mentoring can set individuals up to succeed. This nonexperimental cross-sectional, predictive study examines the Ronald E. McNair Postbaccalaureate Achievement Program's mentoring component. Specific focus is placed on faculty mentor competency and its impact on McNair student intent to…

  1. Examination of Student, Program, and Institutional Support Characteristics That Relate to PGA Golf Management Students' Intent to Persist

    Science.gov (United States)

    Cain, Christopher

    2013-01-01

    The examination of student (entry characteristics, academic performance, career goals, and interaction with peers and faculty), program (programmatic interventions, academic major, and learning communities), and institutional support characteristics (financial aid and residence) that relate to cohort intent to persist are studied among 490 PGA…

  2. Effects of Two Testicular Cancer Education Programs on Self-Examination Knowledge and Attitudes among College-Aged Men.

    Science.gov (United States)

    Marty, Phillip J.; McDermott, Robert J.

    1985-01-01

    This study compared instructional outcomes of two education programs about testicular cancer and testicular self-examination. Instruction facilitated by a former testicular cancer patient was compared to information provided by printed materials. There was no difference in information dissemination, but possible differences in attitude resulted.…

  3. Joint positions matter for ultrasound examination of RA patients-increased power Doppler signal in neutral versus flat position of hands.

    Science.gov (United States)

    Husic, Rusmir; Lackner, Angelika; Stradner, Martin H; Hermann, Josef; Dejaco, Christian

    2017-08-01

    Position of joints might influence the result of US examination in patients with RA. The purpose of this work was to compare grey-scale (GS) and power Doppler (PWD) findings obtained in neutral vs flat position of hands. A cross-sectional study of 42 RA patients with active disease. Two dimensional and 3D sonography of wrists and MCP joints were conducted in two different joint positions: neutral position, which is a slight flexion of the fingers with relaxed extensor muscles; and flat position, where all palm and volar sides of fingers touch the Table. Two dimensional GS synovitis (GSS) and PWD signals were scored semi-quantitatively (0-3). For 3D sonography, the percentage of PWD voxels within a region of interest was calculated. GSS was not quantified using 3D sonography. Compared with neutral position, 2D PWD signals disappeared in 28.3% of joints upon flattening. The median global 2D PWD score (sum of all PWD scores of an individual patient) decreased from 8 to 3 ( P < 0.001), and the global 3D PWD voxel score from 3.8 to 0.9 ( P < 0.001). The reduction of PWD scores was similar in all joints (2D: minus 50%, 3D: minus 66.4-80.1%). Inter- and intrareader agreement of PWD results was good (intraclass correlation coefficient: 0.75-0.82). In RA, a neutral position of the hands is linked to a higher sensitivity of 2D and 3D sonography in detecting PWD signals at wrists and MCP joints, compared with a flat position. Standardization of the scanning procedure is essential for obtaining comparable US results in RA patients in trials and clinical routines. © The Author 2017. Published by Oxford University Press on behalf of the British Society for Rheumatology. All rights reserved. For Permissions, please email: journals.permissions@oup.com

  4. Usefulness of transrectal ultrasound in diagnosing prostate cancer: comparison with digital rectal examination, prostate-specific antigen and prostate-specific antigen density

    International Nuclear Information System (INIS)

    Yoon, Jung Hwan; Kim, Bo Hyun; Choi, Sang Hee; Kim, Seung Hoon; Choi, Han Yong; Chai, Soo Eung; Yoon, Hye Kyung; Lee, Soon Jin; Choo, In Wook; Kim, Bo Kyung

    1998-01-01

    To determine the usefulness of transrectal ultrasonography (TRUS) in diagnosing prostate cancer by comparing the sensitivity, specificity, accuracy, and positive and negative predictive values of TRUS with those of serum prostate-specific antigen (PSA), prostate-specific antigen density (PSAD) and digital rectal examination (DRE). Two hundred and ten consecutive patients underwent TRUS-guided prostate biopsy due to elevated PSA and/or abnormal findings on TRUS or DRE. The TRUS findings were analyzed and correlated with pathological diagnosis. PSAD was calculated by dividing the serum PSA level by the prostate volume calculated on TRUS. The sensitivity, specificity, accuracy, and positive and negative predictive values of TRUS were compared with those of PSA, PSAD and DRE. Using ROC curve analysis, the combinations of these diagnostic methods were also evaluated for the determination of efficacy in diagnosing prostate cancer. The sensitivity and specificity of serum PSA (cut-off level, 4ng/ml), PSAD (cut-off level, 0.15ng/ml/cm 3 ), DRE, and TRUS were 96%/17%, 96%/37%, 72%/62%, and 89%/68%, respectively. On TRUS, the sensitivity and specificity of low echoic lesions and those of irregular outer margin were 89%/69%, and 60%/90%, respectively. TRUS was statistically more accurate than other diagnostic methods. Of the combinations of diagnostic methods, TRUS and PSAD were most accurate. TRUS demonstrated lower sensitivity but higher specificity than PSA or PSAD. Although it is an accurate modality for the diagnosis of prostate cancer, it cannot be used as a confirmative test due to its relatively low positive predictive value. A combination of diagnostic methods and random biopsy is needed in patients in whom prostate cancer is suspected.=20

  5. Examining the Relevance of Emotional Intelligence within Educational Programs for the Gifted and Talented

    Science.gov (United States)

    Bellamy, Al; Gore, David; Sturgis, Judy

    2005-01-01

    This study explored the relationships between emotional intelligence, locus of control, and self-efficacy among gifted and talented students participating in a two week long summer educational program. Results revealed statistically significant correlations between these variables. Gender was found to moderate the relationships. The study also…

  6. A Dynamical Systems Theory Examination of Social Connections in Outdoor Recreation Programs

    Science.gov (United States)

    Jostad, Jeremy

    2015-01-01

    Adolescence is a developmental time period in which social connections are an important aspect to fostering positive growth and identity. Outdoor Adventure Education (OAE) programs are strategically positioned to help in this developmental process because of the novel social environment, however, little is known about how these types of social…

  7. Examining science teachers' pedagogical content knowledge in the context of a professional development program

    NARCIS (Netherlands)

    Wongsopawiro, Dirk Soenario

    2012-01-01

    This dissertation reports on the pedagogical content knowledge (PCK) of science teachers during a professional development program. This research intended to help us understand why and how teachers make their classroom decisions as they teach science. The main questions in this study were: What is

  8. Competency-Based Education in Three Pilot Programs: Examining Implementation and Outcomes

    Science.gov (United States)

    Steele, Jennifer L.; Lewis, Matthew W.; Santibanez, Lucrecia; Faxon-Mills, Susannah; Rudnick, Mollie; Stecher, Brian M.; Hamilton, Laura S.

    2014-01-01

    In 2011, the Bill & Melinda Gates Foundation created the Project Mastery grant program to support competency-based education initiatives in large school systems that serve a high proportion of disadvantaged youth. Competency-based education meets students where they are academically, provides students with opportunities for choice, and awards…

  9. Body Talk: Examining a Collaborative Multiple-Visit Program for Visitors with Eating Disorders

    Science.gov (United States)

    Baddeley, Gwen; Evans, Laura; Lajeunesse, Marilyn; Legari, Stephen

    2017-01-01

    "Sharing the Douglas/Sharing the Museum," a collaboration program of the Montreal Museum of Fine Arts (MMFA), the Douglas Mental Health Institute and the Department of Creative Arts Therapies at Concordia University, serves patients from the Eating Disorder Unit of the Douglas. Participants eat lunch at the museum and look at, talk…

  10. Curricular Abstinence: Examining Human Sexuality Training in School Counselor Preparation Programs

    Science.gov (United States)

    Behun, Richard Joseph; Cerrito, Julie A.; Delmonico, David L.; Campenni, Estelle

    2017-01-01

    Professional school counselors (PSCs; N = 486) rated their level of perceived preparedness acquired in their school counselor preparation program with respect to knowledge, skills, and self-awareness of five human sexuality domains (behavior, health, morality, identity, violence) across grade level (elementary vs. secondary) and three human…

  11. Examining the Preliminary Efficacy of a Dating Violence Prevention Program for Hispanic Adolescents

    Science.gov (United States)

    Gonzalez-Guarda, Rosa Maria; Guerra, Jessica E.; Cummings, Amanda A.; Pino, Karen; Becerra, Maria M.

    2015-01-01

    The purpose of this study is to evaluate the preliminary efficacy of a dating violence (DV) prevention program for Cuban American adolescents ("JOVEN"/YOUTH: "Juntos Opuestos a la Violence Entre Novios"/Together Against Dating Violence). A randomized-controlled experimental design with a delayed condition was used to evaluate…

  12. A Review of Research Methods Used to Examine Employee Assistance Program Delivery Options.

    Science.gov (United States)

    Csiernik, Rick

    1995-01-01

    This review of literature on Employee Assistance Programs (EAPs) focuses on EAP delivery options. More than half of the 48 studies reviewed used a case study approach. EAPs provided by on-staff professionals were the most frequently discussed delivery option, although this is not the most dominant form of EAP provision. (SLD)

  13. An Examination of Job Skills Posted on Internet Databases: Implications for Information Systems Degree Programs.

    Science.gov (United States)

    Liu, Xia; Liu, Lai C.; Koong, Kai S.; Lu, June

    2003-01-01

    Analysis of 300 information technology job postings in two Internet databases identified the following skill categories: programming languages (Java, C/C++, and Visual Basic were most frequent); website development (57% sought SQL and HTML skills); databases (nearly 50% required Oracle); networks (only Windows NT or wide-area/local-area networks);…

  14. Ultrasonographic examination of plantar fasciitis: a comparison of patient positions during examination.

    Science.gov (United States)

    Ahn, Jae Hoon; Lee, Choong Woo; Park, ChanJoo; Kim, Yoon-Chung

    2016-01-01

    Musculoskeletal ultrasound is a non-invasive and low-cost modality for real-time visualisation of the plantar fascia. Ultrasound examination for plantar fasciitis is generally performed with the patient in a prone position, although the rational for using a prone position has not been validated. The aim of the study was to investigate if ultrasound examination in a supine position, which is more comfortable than the prone position, is valid. We conducted a prospective study of 30 participants with plantar fasciitis, 8 men (27 %) and 22 women (73 %), with a mean age of 53.9 ± 12.6 (range, 32 to 77) years, and an equal distribution of left and right feet. The plantar heel was divided into three portions for ultrasound examination: medial, central and lateral. Two measurements of plantar fascia thickness were obtained for each portion, with participants in 2 positions (supine and prone) and for 2 ankle postures (neutral and 15° of plantarflexion). Mean measurements of plantar fascia thickness were compared between the two positions (Wilcoxon signed rank tests for non-normally distributed data and paired t-tests for normally distributed data). Participants were asked to report their preferred position for examination, supine or prone. The measured thickness was comparable for both supine and prone positions, for both ankle postures, neutral and 15° of plantarflexion (p > 0.05). A specific self-reported preferred position was not identified. Ultrasound examination of plantar fasciitis can be performed in the supine position without any significant difference in measurement compared to examination in the conventional prone position. The Catholic Medical Center Office of Human Research Protection Program (CMC-OHRP)/Institutional Review Board approved the current study (Approval No. KC12DISI0338), and all participants provided their written informed consent for participation and publication.

  15. Ultrasound in Space Medicine

    Science.gov (United States)

    Dulchavsky, Scott A.; Sargsyan, A.E.

    2009-01-01

    This slide presentation reviews the use of ultrasound as a diagnostic tool in microgravity environments. The goals of research in ultrasound usage in space environments are: (1) Determine accuracy of ultrasound in novel clinical conditions. (2) Determine optimal training methodologies, (3) Determine microgravity associated changes and (4) Develop intuitive ultrasound catalog to enhance autonomous medical care. Also uses of Ultrasound technology in terrestrial applications are reviewed.

  16. TMI-2 core-examination program: INEL facilities-readiness study

    International Nuclear Information System (INIS)

    McLaughlin, T.B.

    1982-09-01

    This document is a review of the Idaho National Engineering Laboratory's (INEL) remote handling facilities. Their availability and readiness to conduct examination and analyses of TMI-2 core samples was determined. Examination of these samples require that the facilities be capable of receiving commercial casks, unloading canisters from the casks, opening the canisters, handling the fuel debris and assemblies, and performing various examinations. The documentation that was necessary for the INEL to have before the receipt of the core material was identified. The core information was also required for input to these documents. The costs, schedules, and a preliminary-project plan are presented for the tasks which are identified as prerequisites to the receipt of the first core sample

  17. CANADA’S MOTHER-CHILD PROGRAM: EXAMINING ITS EMERGENCE, USAGE, AND CURRENT STATE

    Directory of Open Access Journals (Sweden)

    Sarah Brennan

    2014-04-01

    Full Text Available One of many issues a mother must face while incarcerated is separation from her child(ren for an extended period of time. Empirical findings have consistently highlighted various negative effects for both mothers and their children as a result of this separation. To curb some of the negative effects, Correctional Service Canada’s Mother-Child Program offers full- and part-time visitation between children and their incarcerated mothers at various women’s federal correctional facilities in Canada. The current study involves an in-depth critical analysis of Canada’s MCP by asking three related questions. First, to what extent has the MCP been used since its full implementation in 2001? Second, to what extent is the MCP used today? Third, do any barriers exist currently that are inhibiting the success of the MCP and, if so, how can these be addressed? The results of the study reveal that, since the full implementation of the program in 2001, the participation rate declined from an already low starting point and has remained relatively low since. Further, three main factors were suggested as potential barriers impeding the success of the MCP: correctional overcrowding, a more punitive institutional culture, and a series of changes to the program’s eligibility criteria. Recommendations on ways to increase the usage of the program are offered and suggestions for future research are made.

  18. Examining the psychological pathways to behavior change in a group-based lifestyle program to prevent type 2 diabetes.

    Science.gov (United States)

    Critchley, Christine R; Hardie, Elizabeth A; Moore, Susan M

    2012-04-01

    To examine the psychological process of lifestyle change among adults at risk for type 2 diabetes. A randomized control trial in which 307 volunteers (intervention, n = 208; wait control, n = 99) diagnosed with prediabetes completed a six-session group-based intervention to promote healthier living. Participants' motivation to change, diet and exercise self-efficacy, mood, knowledge about diabetes, activity levels, healthy eating, waist circumference, and weight were assessed before and after the program. Participation in the program was associated with significant increases in healthy eating and physical activity, reductions in waist and weight, and improvements in motivation, positive mood, self-efficacy, and knowledge. Examination of the pathways to lifestyle change showed that the educational aspect of the program increased activity levels because it increased diabetes knowledge and improved mood. Eating behavior was not mediated by any of the psychological variables. Improvements in diet and physical activity were, in turn, directly associated with changes in weight and waist circumference. Although the program significantly improved motivation, self-efficacy, and mood, its impact on knowledge uniquely explained the increase in physical activity. Group-based programs that are tailored to lifestyle behaviors may provide a cost-effective method of diabetes prevention, but more research is needed to explain why they improve healthy eating.

  19. End-of-life destructive examination of light water breeder reactor fuel rods (LWBR Development Program)

    International Nuclear Information System (INIS)

    Richardson, K.D.

    1987-10-01

    Destructive examination of 12 representative Light Water Breeder Reactor fuel rods was performed following successful operation in the Shippingport Atomic Power Station for 29,047 effective full power hours, about five years. Light Water Breeder Reactor fuel rods were unique in that the thorium oxide and uranium-233 oxide fuel was contained within Zircaloy-4 cladding. Destructive examinations included analysis of released fission gas; chemical analysis of the fuel to determine depletion, iodine, and cesium levels; chemical analysis of the cladding to determine hydrogen, iodine, and cesium levels; metallographic examination of the cladding, fuel, and other rod components to determine microstructural features and cladding corrosion features; and tensile testing of the irradiated cladding to determine mechanical strength. The examinations confirmed that Light Water Breeder Reactor fuel rod performance was excellent. No evidence of fuel rod failure was observed, and the fuel operating temperature was low (below 2580 0 F at which an increased percentage of fission gas is released). 21 refs., 80 figs., 20 tabs

  20. Children's (Pediatric) Abdominal Ultrasound Imaging

    Medline Plus

    Full Text Available ... body tissue through which the sound travels. A small amount of gel is put on the skin to allow the sound waves to travel from the transducer to the examined area within the body and then back again. Ultrasound ...