WorldWideScience

Sample records for programmable diagnostic instruments

  1. 21 CFR 870.1425 - Programmable diagnostic computer.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Programmable diagnostic computer. 870.1425 Section 870.1425 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES... diagnostic computer. (a) Identification. A programmable diagnostic computer is a device that can be...

  2. Development of an instrument to measure the clinical learning environment in diagnostic radiology

    International Nuclear Information System (INIS)

    Bloomfield, L.; Subramaniam, R.

    2008-01-01

    A clinical learning environment survey instrument was developed that provided insights into diagnostic radiology trainees' perceptions of the culture and context of the hospital-based training programme. The survey was completed by trainees allocated to 37 important training hospitals in Australia, New Zealand and Singapore in 2006. The main findings were that most obvious strengths of the diagnostic radiology programme are the wide variety of work-based learning opportunities and the social atmosphere. These were well regarded in all training sites. Work overload was seen as a significant problem in most hospitals and will probably remain a challenge. The areas that are most likely to repay efforts to bring about change are supervision and feedback. The study provides baseline data against which the influence of changes to the training programme may be evaluated.

  3. Introducing new diagnostics into STI control programmes: the importance of programme science.

    Science.gov (United States)

    Peeling, Rosanna W; Mabey, David; Ballard, Ronald C

    2013-03-01

    Many innovative diagnostic technologies will become commercially available over the next 5-10 years. These tests can potentially transform the diagnosis of sexually transmitted infections but their introduction into control programmes can be hampered by health system constraints, and political, cultural, socioeconomic and behavioural factors. We used the introduction of syphilis rapid tests to illustrate the importance of programme science to address the gap between accruing evidence of acceptable test performance and the complexity of programme design, implementation and evaluation of test deployment to address public health needs and improve patient-important outcomes.

  4. Cost effectiveness of rural development programme instruments in Denmark

    DEFF Research Database (Denmark)

    Jensen, J Dejgaard; Jakobsen, L; Madsen, B

    2011-01-01

    The objective of this study is to investigate the cost-effectiveness of selected instruments of the Danish Rural Development Programme 2007-2013, which constitutes the Danish implementation of the EU Rural Development Programme under Pillar Two of the Common Agricultural Policy. The Programme aims...... to support sustainable economic growth and income diversification in rural areas (and in particular in economically vulnerable areas). The study combines different datasets and simulation models at farm level (register data, Farm Accountancy Data, farm sector model, run-off models, etc.), municipality level...... (micro-based “National Accounts” for municipalities, municipality economic model) and national level (national economic model), which enables analysis at a fairly detailed geographical level and hence to evaluate the spatially distributed effects of the considered policy instruments, while at the same...

  5. Beam Instrumentation and Diagnostics

    CERN Document Server

    Strehl, Peter

    2006-01-01

    This treatise covers all aspects of the design and the daily operations of a beam diagnostic system for a large particle accelerator. A very interdisciplinary field, it involves contributions from physicists, electrical and mechanical engineers and computer experts alike so as to satisfy the ever-increasing demands for beam parameter variability for a vast range of operation modi and particles. The author draws upon 40 years of research and work, most of them spent as the head of the beam diagnostics group at GSI. He has illustrated the more theoretical aspects with many real-life examples that will provide beam instrumentation designers with ideas and tools for their work.

  6. Target Diagnostic Instrument-Based Controls Framework for the National Ignition Facility

    International Nuclear Information System (INIS)

    Shelton, R; O'Brien, D; Nelson, J; Kamperschroer, J

    2007-01-01

    NIF target diagnostics are being developed to observe and measure the extreme physics of targets irradiated by the 192-beam laser. The response time of target materials can be on the order of 100ps--the time it takes light to travel 3 cm--temperatures more than 100 times hotter than the surface of the sun, and pressures that exceed 109 atmospheres. Optical and x-ray diagnostics were developed and fielded to observe and record the results of the first 4-beam experiments at NIF. Hard and soft x-ray spectra were measured, and time-integrated and gated x-ray images of hydrodynamics experiments were recorded. Optical diagnostics recorded backscatter from the target, and VISAR laser velocimetry measurements were taken of laser-shocked target surfaces. Additional diagnostics are being developed and commissioned to observe and diagnose ignition implosions, including various neutron and activation diagnostics. NIF's diagnostics are being developed at LLNL and with collaborators at other sites. To accommodate the growing number of target diagnostics, an Instrument-Based Controls hardware-software framework has been developed to facilitate development and ease integration into the NIF Integrated Computer Control System (ICCS). Individual WindowsXP PC controllers for each digitizer, power supply and camera (i.e., instruments) execute controls software unique to each instrument model. Each hardware-software controller manages a single instrument, in contrast to the complexity of combining all the controls software needed for a diagnostic into a single controller. Because of this simplification, controllers can be more easily tested on the actual hardware, evaluating all normal and off-normal conditions. Each target diagnostic is then supported by a number of instruments, each with its own hardware-software instrument-based controller. Advantages of the instrument-based control architecture and framework include reusability, testability, and improved reliability of the deployed

  7. Target Diagnostic Instrument-Based Controls Framework for the National Ignition Facility

    Energy Technology Data Exchange (ETDEWEB)

    Shelton, R; O' Brien, D; Nelson, J; Kamperschroer, J

    2007-05-07

    NIF target diagnostics are being developed to observe and measure the extreme physics of targets irradiated by the 192-beam laser. The response time of target materials can be on the order of 100ps--the time it takes light to travel 3 cm--temperatures more than 100 times hotter than the surface of the sun, and pressures that exceed 109 atmospheres. Optical and x-ray diagnostics were developed and fielded to observe and record the results of the first 4-beam experiments at NIF. Hard and soft x-ray spectra were measured, and time-integrated and gated x-ray images of hydrodynamics experiments were recorded. Optical diagnostics recorded backscatter from the target, and VISAR laser velocimetry measurements were taken of laser-shocked target surfaces. Additional diagnostics are being developed and commissioned to observe and diagnose ignition implosions, including various neutron and activation diagnostics. NIF's diagnostics are being developed at LLNL and with collaborators at other sites. To accommodate the growing number of target diagnostics, an Instrument-Based Controls hardware-software framework has been developed to facilitate development and ease integration into the NIF Integrated Computer Control System (ICCS). Individual WindowsXP PC controllers for each digitizer, power supply and camera (i.e., instruments) execute controls software unique to each instrument model. Each hardware-software controller manages a single instrument, in contrast to the complexity of combining all the controls software needed for a diagnostic into a single controller. Because of this simplification, controllers can be more easily tested on the actual hardware, evaluating all normal and off-normal conditions. Each target diagnostic is then supported by a number of instruments, each with its own hardware-software instrument-based controller. Advantages of the instrument-based control architecture and framework include reusability, testability, and improved reliability of the

  8. Audit Programmes in a Diagnostic Radiological Facility (invited paper)

    International Nuclear Information System (INIS)

    Moores, B.M.; Connolly, P.A.; Cole, P.R.

    1998-01-01

    The effective implementation of optimisation strategies for radiation protection in diagnostic radiology including nuclear medicine requires mechanisms for ongoing audit of all relevant factors. The Quality Criteria of the Commission of European Communities highlights clearly the three aspects of a radiological examination which needed to be considered, which are: (i) radiographic technique, (ii) patient dose, and (iii) image quality. Therefore, it is important that the choice of a known and acceptable radiographic technique provides a known outcome in terms of patient dose and image quality. This requirement should be capable of being achieved throughout Europe and capable of being updated as new radiological strategies are developed. Audit programmes aimed at monitoring that this situation exists may be considered at three levels: Level 1 involves routine, periodic, assessment of patient doses on a representative sample of patients undergoing a particular type of examination. Results from this audit are then compared with acceptable and clearly defined diagnostic reference levels or reference dose values which provides a framework for guidance on acceptable practice. A summary of such level 1 programmes which are being pursued in Europe is presented. Level 2 audit programmes, beside patient dose assessment, will also involve an assessment of all those parameters relevant to an X ray examination which may have a bearing on the actual dose delivered to the patient. Such level 2 audit programmes provide the basis for implementation of optimisation strategies for radiation protection in terms of risk reduction, one of the fundamental tenets of radiation protection philosophy. Level 3 audit programmes also include assessment and verification of image quality requirements for particular examinations. This latter aspect is a necessary basis for overall optimisation of radiation protection in diagnostic radiology. (author)

  9. Study of the performance of diagnostic radiology instruments during calibration

    International Nuclear Information System (INIS)

    Freitas, Rodrigo N. de; Vivolo, Vitor; Potiens, Maria da Penha A.

    2008-01-01

    Full text: The instruments used in diagnostic radiology measurements represent 8 % of the tested instruments by the calibration laboratory of IPEN annually (approximately 1600 in 2007). Considering that the calibration of this kind of instrument is performed biannually it is possible to conclude that almost 300 instruments are being used to measure the air kerma in diagnostic radiology clinics to determine the in beam values (in front of the patient), attenuated measurements (behind the patient) and scattered radiation. This work presents the results of the calibration of the instruments used in mammography, computed tomography, dental and conventional diagnostic radiology dosimetry, performed during the period of 2005 to 2007. Their performances during the calibrations measurements were evaluated. Although at the calibration laboratory there are three available series of radiation quality to this type of calibration (RQR, N and M, according to standards IEC 61267 and ISO 4037-1.), the applications can be assorted (general radiology, computed tomography, mammography, radiation protection and fluoroscopy). Depending on its design and behaviour , one kind of instrument can be used for one or more type of applications. The instruments normally used for diagnostic radiology measurements are ionization chambers with volumes varying from 3 to 1800 cm 3 , and can be cylindrical, spherical or plane parallel plates kind. They usually are sensitive to photon particles, with energies greater than 15 keV and can be used up to 1200 keV. In this work they were tested in X radiation fields from 25 to 150 kV, in specific qualities depending on the utilization of the instrument. The calibration results of 390 instruments received from 2005 to 2007 were analyzed. About 20 instruments were not able to be calibrated due to bad functioning. The calibration coefficients obtained were between 0.88 and 1.24. The uncertainties were always less than ± 3.6% to instruments used in scattered

  10. Quality Assurance Programme for Computed Tomography: Diagnostic and Therapy Applications

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2012-08-15

    This publication presents a harmonized approach to quality assurance in the field of computed tomography applied to both diagnostics and therapy. It gives a careful analysis of the principles and specific instructions that can be used for a quality assurance programme for optimal performance and reduced patient dose in diagnostic radiology. In some cases, radiotherapy programmes are making a transition from 2-D to 3-D radiotherapy, a complex process which critically depends on accurate treatment planning. In this respect, the authors also provide detailed information about the elements needed for quality assurance testing, including those relating to accurate patient characterization as needed for radiotherapy treatment planning.

  11. PECULIARITIES OF PROGRAMME MUSIC IN THE INSTRUMENTAL SUITE OF COMPOSERS FROM THE REPUBLIC OF MOLDOVA

    Directory of Open Access Journals (Sweden)

    BEREZOVICOVA TATIANA

    2015-09-01

    Full Text Available The article is dedicated to the study of the instrumental suites written by native composers from the point of view of the realization of programme music. The author analyses different kinds of programme music such as genre, stylistic, pictorial (without any subject, with a generalized subject, with a concrete subject, as well as latent programme music, felt in some non-programme compositions declared and expressed through specific instrumental means.

  12. Report of the 2. research co-ordination meeting of the co-ordinated research programme on the development of computer-based troubleshooting tools and instruments

    International Nuclear Information System (INIS)

    1998-11-01

    The Research coordination meeting reviewed current results on the Development of Computer-Based Troubleshooting Tools and Instruments. Presentations at the meeting were made by the participants, and the project summary reports include: PC based software for troubleshooting microprocessor-based instruments; technical data base software; design and construction of a random pulser for maintenance and quality control of a nuclear counting system; microprocessor-based power conditioner; in-circuit emulator for microprocessor-based nuclear instruments; PC-based analog signal generator for simulated detector signals and arbitrary test waveforms for testing of nuclear instruments; expert system for nuclear instrument troubleshooting; development and application of versatile computer-based measurement and diagnostic tools; and development of a programmable signal generator for troubleshooting of nuclear instrumentation

  13. Instrumentation

    Energy Technology Data Exchange (ETDEWEB)

    Decreton, M

    2001-04-01

    SCK-CEN's research and development programme on instrumentation involves the assessment and the development of sensitive measurement systems used within a radiation environment. Particular emphasis is on the assessment of optical fibre components and their adaptability to radiation environments. The evaluation of ageing processes of instrumentation in fission plants, the development of specific data evaluation strategies to compensate for ageing induced degradation of sensors and cable performance form part of these activities. In 2000, particular emphasis was on in-core reactor instrumentation applied to fusion, accelerator driven and water-cooled fission reactors. This involved the development of high performance instrumentation for irradiation experiments in the BR2 reactor in support of new instrumentation needs for MYRRHA, and for diagnostic systems for the ITER reactor.

  14. Instrumentation

    International Nuclear Information System (INIS)

    Decreton, M.

    2001-01-01

    SCK-CEN's research and development programme on instrumentation involves the assessment and the development of sensitive measurement systems used within a radiation environment. Particular emphasis is on the assessment of optical fibre components and their adaptability to radiation environments. The evaluation of ageing processes of instrumentation in fission plants, the development of specific data evaluation strategies to compensate for ageing induced degradation of sensors and cable performance form part of these activities. In 2000, particular emphasis was on in-core reactor instrumentation applied to fusion, accelerator driven and water-cooled fission reactors. This involved the development of high performance instrumentation for irradiation experiments in the BR2 reactor in support of new instrumentation needs for MYRRHA, and for diagnostic systems for the ITER reactor

  15. A Programmable Biopotential Aquisition Front-end with a Resistance-free Current-balancing Instrumentation Amplifier

    Directory of Open Access Journals (Sweden)

    FARAGO, P.

    2018-05-01

    Full Text Available The development of wearable biomedical equipment benefits from low-power and low-voltage circuit techniques for reduced battery size and battery, or even battery-less, operation. This paper proposes a fully-differential low-power resistance-free programmable instrumentation amplifier for the analog front-end of biopotential monitoring systems. The proposed instrumentation amplifier implements the current balancing technique. Low power consumption is achieved with subthreshold biasing. To reduce chip area and enable integration, passive resistances have been replaced with active equivalents. Accordingly, the instrumentation amplifier gain is expressed as the ratio of two transconductance values. The proposed instrumentation amplifier exhibits two degrees of freedom: one to set the desired range and the other for fine-tuning of the voltage gain. The proposed IA is employed in a programmable biopotential acquisition front-end. The programmable frequency-selective behavior is achieved by having the lower cutoff frequency of a Gm-C Tow-Thomas biquad varied in a constant-C tuning approach. The proposed solutions and the programmability of the operation parameters to the specifications of particular bio-medical signals are validated on a 350nm CMOS process.

  16. Instrumental tactile diagnostics in robot-assisted surgery

    Directory of Open Access Journals (Sweden)

    Solodova RF

    2016-10-01

    Full Text Available Rozalia F Solodova,1,2 Vladimir V Galatenko,1,2 Eldar R Nakashidze,3 Igor L Andreytsev,3 Alexey V Galatenko,1 Dmitriy K Senchik,2 Vladimir M Staroverov,1 Vladimir E Podolskii,1,2 Mikhail E Sokolov,1,2 Victor A Sadovnichy1,2 1Faculty of Mechanics and Mathematics, 2Institute of Mathematical Studies of Complex Systems, Lomonosov Moscow State University, 31st Surgery Department, Clinical Hospital 31, Moscow, Russia Background: Robotic surgery has gained wide acceptance due to minimizing trauma in patients. However, the lack of tactile feedback is an essential limiting factor for the further expansion. In robotic surgery, feedback related to touch is currently kinesthetic, and it is mainly aimed at the minimization of force applied to tissues and organs. Design and implementation of diagnostic tactile feedback is still an open problem. We hypothesized that a sufficient tactile feedback in robot-assisted surgery can be provided by utilization of Medical Tactile Endosurgical Complex (MTEC, which is a novel specialized tool that is already commercially available in the Russian Federation. MTEC allows registration of tactile images by a mechanoreceptor, real-time visualization of these images, and reproduction of images via a tactile display. Materials and methods: Nine elective surgeries were performed with da Vinci™ robotic system. An assistant performed tactile examination through an additional port under the guidance of a surgeon during revision of tissues. The operating surgeon sensed registered tactile data using a tactile display, and the assistant inspected the visualization of tactile data. First, surgeries where lesion boundaries were visually detectable were performed. The goal was to promote cooperation between the surgeon and the assistant and to train them in perception of the tactile feedback. Then, instrumental tactile diagnostics was utilized in case of visually undetectable boundaries. Results: In robot-assisted surgeries where lesion

  17. Beam diagnostic instruments of TARN

    International Nuclear Information System (INIS)

    Watanabe, Shin-ichi.

    1987-09-01

    The paper summarizes the beam diagnostic instruments of the low energy ion accumulation ring; TARN. With these monitors, position, profiles, bunch structure, intensity, emittance and momentum spread were measured to evaluate the injection and stacking experiments. The monitors provide the sensitivity of a few μA for the nondestructive and a few nA for the destructive monitors. Discussions on monitor probe and electronics are presented on the basis of an achievement of the beam stacking experiments. (author)

  18. Instrumentation

    International Nuclear Information System (INIS)

    Decreton, M.

    2002-01-01

    SCK-CEN's R and D programme on instrumentation involves the development of advanced instrumentation systems for nuclear applications as well as the assessment of the performance of these instruments in a radiation environment. Particular emphasis is on the use of optical fibres as umbilincal links of a remote handling unit for use during maintanance of a fusion reacor, studies on the radiation hardening of plasma diagnostic systems; investigations on new instrumentation for the future MYRRHA accelerator driven system; space applications related to radiation-hardened lenses; the development of new approaches for dose, temperature and strain measurements; the assessment of radiation-hardened sensors and motors for remote handling tasks and studies of dose measurement systems including the use of optical fibres. Progress and achievements in these areas for 2001 are described

  19. Instrumentation

    Energy Technology Data Exchange (ETDEWEB)

    Decreton, M

    2002-04-01

    SCK-CEN's R and D programme on instrumentation involves the development of advanced instrumentation systems for nuclear applications as well as the assessment of the performance of these instruments in a radiation environment. Particular emphasis is on the use of optical fibres as umbilincal links of a remote handling unit for use during maintanance of a fusion reacor, studies on the radiation hardening of plasma diagnostic systems; investigations on new instrumentation for the future MYRRHA accelerator driven system; space applications related to radiation-hardened lenses; the development of new approaches for dose, temperature and strain measurements; the assessment of radiation-hardened sensors and motors for remote handling tasks and studies of dose measurement systems including the use of optical fibres. Progress and achievements in these areas for 2001 are described.

  20. Evaluating Secondary Students' Scientific Reasoning in Genetics Using a Two-Tier Diagnostic Instrument

    Science.gov (United States)

    Tsui, Chi-Yan; Treagust, David

    2010-05-01

    While genetics has remained as one key topic in school science, it continues to be conceptually and linguistically difficult for students with the concomitant debates as to what should be taught in the age of biotechnology. This article documents the development and implementation of a two-tier multiple-choice instrument for diagnosing grades 10 and 12 students' understanding of genetics in terms of reasoning. The pretest and posttest forms of the diagnostic instrument were used alongside other methods in evaluating students' understanding of genetics in a case-based qualitative study on teaching and learning with multiple representations in three Western Australian secondary schools. Previous studies have shown that a two-tier diagnostic instrument is useful in probing students' understanding or misunderstanding of scientific concepts and ideas. The diagnostic instrument in this study was designed and then progressively refined, improved, and implemented to evaluate student understanding of genetics in three case schools. The final version of the instrument had Cronbach's alpha reliability of 0.75 and 0.64, respectively, for its pretest and the posttest forms when it was administered to a group of grade 12 students (n = 17). This two-tier diagnostic instrument complemented other qualitative data collection methods in this research in generating a more holistic picture of student conceptual learning of genetics in terms of scientific reasoning. Implications of the findings of this study using the diagnostic instrument are discussed.

  1. Diagnostic inertia in dyslipidaemia: results of a preventative programme in Spain.

    Science.gov (United States)

    Palazón-Bru, Antonio; Sepehri, Armina; Ramírez-Prado, Dolores; Navarro-Cremades, Felipe; Cortés, Ernesto; Rizo-Baeza, Mercedes; Gil-Guillén, Vicente Francisco

    2015-01-01

    Others have analysed the relationship between inadequate behaviour by healthcare professionals in the diagnosis of dyslipidaemia (diagnostic inertia) and the history of cardiovascular risk factors. However, since no study has assessed cardiovascular risk scores as associated factors, we carried out a study to quantify diagnostic inertia in dyslipidaemia and to determine if cardiovascular risk scores are associated with this inertia. In the Valencian Community (Spain), a preventive programme (cardiovascular, gynaecologic and vaccination) was started in 2003 inviting persons aged ≥40 years to undergo a health check-up at their health centre. This cross-sectional study examined persons with no known dyslipidaemia seen during the first six months of the programme (n = 16, 905) but whose total cholesterol (TC) was ≥5.17 mmol/L. Diagnostic inertia was defined as lack of follow-up to confirm/discard the dyslipidaemia diagnosis. Other variables included in the analysis were gender, history of cardiovascular risk factors/cardiovascular disease, counselling (diet/exercise), body mass index (BMI), age, blood pressure, fasting blood glucose and lipids. TC was grouped as ≥/Inertia was quantified and the adjusted odds ratios calculated from multivariate models. In the overall sample, the rate of diagnostic inertia was 52% (95% CI [51.2-52.7]); associated factors were TC ≥ 6.20 mmol/L, high or "not measured" BMI, hypertension, smoking and higher values of fasting blood glucose, systolic blood pressure and TC. In the REGICOR sample, the rate of diagnostic inertia was 51.9% (95% CI [51.1-52.7]); associated factors were REGICOR high and high or "not measured" BMI. In the SCORE sample the rate of diagnostic inertia was 51.7% (95% CI [50.9-52.5]); associated factors were SCORE high and high or "not measured" BMI. Diagnostic inertia existed in over half the patients and was associated with a greater cardiovascular risk.

  2. Diagnostic instrumentation for detection of the onset of steam tube leaks in PWRs

    International Nuclear Information System (INIS)

    Roach, W.H.

    1984-01-01

    Four tasks are addressed in this study of the detection of steam tube leaks: determination of which physical parameters indicate the onset of steam generator tube leaks; establishing performance goals for diagnostic instruments which could be used for early detection of steam generator tube leaks; defining the diagnostic instrumentation and their location which satisfy Items 1 and 2; and assessing the need for diagnostic data processing and display. Parameters are identified, performance goals established and sensor types and locations are specified in the report, with emphasis on the use of existing instrumentation with a minimum of retrofitting. A simple algorithm is developed which yields the leak rate as a function of known or measurable quantities. The conclusion is that leak rates of less than one-tenth gram per second should be detectable with existing instrumentation

  3. User interface on networked workstations for MFTF plasma diagnostic instruments

    International Nuclear Information System (INIS)

    Renbarger, V.L.; Balch, T.R.

    1985-01-01

    A network of Sun-2/170 workstations is used to provide an interface to the MFTF-B Plasma Diagnostics System at Lawrence Livermore National Laboratory. The Plasma Diagnostics System (PDS) is responsible for control of MFTF-B plasma diagnostic instrumentation. An EtherNet Local Area Network links the workstations to a central multiprocessing system which furnishes data processing, data storage and control services for PDS. These workstations permit a physicist to command data acquisition, data processing, instrument control, and display of results. The interface is implemented as a metaphorical desktop, which helps the operator form a mental model of how the system works. As on a real desktop, functions are provided by sheets of paper (windows on a CRT screen) called worksheets. The worksheets may be invoked by pop-up menus and may be manipulated with a mouse. These worksheets are actually tasks that communicate with other tasks running in the central computer system. By making entries in the appropriate worksheet, a physicist may specify data acquisition or processing, control a diagnostic, or view a result

  4. Characterization of the Goubau line for testing beam diagnostic instruments

    Science.gov (United States)

    Kim, S. Y.; Stulle, F.; Sung, C. K.; Yoo, K. H.; Seok, J.; Moon, K. J.; Choi, C. U.; Chung, Y.; Kim, G.; Woo, H. J.; Kwon, J.; Lee, I. G.; Choi, E. M.; Chung, M.

    2017-12-01

    One of the main characteristics of the Goubau line is that it supports a low-loss, non-radiated surface wave guided by a dielectric-coated metal wire. The dominant mode of the surface wave along the Goubau line is a TM01 mode, which resembles the pattern of the electromagnetic fields induced in the metallic beam pipe when the charged particle beam passes through it. Therefore, the Goubau line can be used for the preliminary bench test and performance optimization of the beam diagnostic instruments without requiring charged particle beams from the accelerators. In this paper, we discuss the basic properties of the Goubau line for testing beam diagnostic instruments and present the initial test results for button-type beam position monitors (BPMs). The experimental results are consistent with the theoretical estimations, which indicates that Goubau line allows effective testing of beam diagnostic equipment.

  5. A Research Agenda for Helminth Diseases of Humans: Diagnostics for Control and Elimination Programmes

    Science.gov (United States)

    McCarthy, James S.; Lustigman, Sara; Yang, Guo-Jing; Barakat, Rashida M.; García, Héctor H.; Sripa, Banchob; Willingham, Arve Lee; Prichard, Roger K.; Basáñez, María-Gloria

    2012-01-01

    Diagnostic tools appropriate for undertaking interventions to control helminth infections are key to their success. Many diagnostic tests for helminth infection have unsatisfactory performance characteristics and are not well suited for use in the parasite control programmes that are being increasingly implemented. Although the application of modern laboratory research techniques to improve diagnostics for helminth infection has resulted in some technical advances, uptake has not been uniform. Frequently, pilot or proof of concept studies of promising diagnostic technologies have not been followed by much needed product development, and in many settings diagnosis continues to rely on insensitive and unsatisfactory parasitological or serodiagnostic techniques. In contrast, PCR-based xenomonitoring of arthropod vectors, and use of parasite recombinant proteins as reagents for serodiagnostic tests, have resulted in critical advances in the control of specific helminth parasites. The Disease Reference Group on Helminths Infections (DRG4), established in 2009 by the Special Programme for Research and Training in Tropical Diseases (TDR) was given the mandate to review helminthiases research and identify research priorities and gaps. In this review, the diagnostic technologies relevant to control of helminth infections, either available or in development, are reviewed. Critical gaps are identified and opportunities to improve needed technologies are discussed. PMID:22545166

  6. Diagnostic inertia in dyslipidaemia: results of a preventative programme in Spain

    Directory of Open Access Journals (Sweden)

    Antonio Palazón-Bru

    2015-07-01

    Full Text Available Others have analysed the relationship between inadequate behaviour by healthcare professionals in the diagnosis of dyslipidaemia (diagnostic inertia and the history of cardiovascular risk factors. However, since no study has assessed cardiovascular risk scores as associated factors, we carried out a study to quantify diagnostic inertia in dyslipidaemia and to determine if cardiovascular risk scores are associated with this inertia. In the Valencian Community (Spain, a preventive programme (cardiovascular, gynaecologic and vaccination was started in 2003 inviting persons aged ≥40 years to undergo a health check-up at their health centre. This cross-sectional study examined persons with no known dyslipidaemia seen during the first six months of the programme (n = 16, 905 but whose total cholesterol (TC was ≥5.17 mmol/L. Diagnostic inertia was defined as lack of follow-up to confirm/discard the dyslipidaemia diagnosis. Other variables included in the analysis were gender, history of cardiovascular risk factors/cardiovascular disease, counselling (diet/exercise, body mass index (BMI, age, blood pressure, fasting blood glucose and lipids. TC was grouped as ≥/<6.20 mmol/L. In patients without cardiovascular disease and <75/≤65 years (n = 15, 778/13, 597, the REGICOR (REgistre GIroní del COr/SCORE (Systematic COronary Risk Evaluation cardiovascular risk functions were used to classify risk (high/low. Inertia was quantified and the adjusted odds ratios calculated from multivariate models. In the overall sample, the rate of diagnostic inertia was 52% (95% CI [51.2–52.7]; associated factors were TC ≥ 6.20 mmol/L, high or “not measured” BMI, hypertension, smoking and higher values of fasting blood glucose, systolic blood pressure and TC. In the REGICOR sample, the rate of diagnostic inertia was 51.9% (95% CI [51.1–52.7]; associated factors were REGICOR high and high or “not measured” BMI. In the SCORE sample the rate of diagnostic

  7. Heterodyne quasi-elastic light-scattering instrument for biomedical diagnostics.

    Science.gov (United States)

    Lebedev, A D; Ivanova, M A; Lomakin, A V; Noskin, V A

    1997-10-20

    The heterodyne technique has a number of advantages over the homodyne technique when an accurate characterization of particle-size distribution (PSD) of heterogeneous systems is required. However, there are problems related to acoustic vibrations that make it difficult to take advantage of the heterodyne technique. An instrument developed for quasi-elastic light scattering (QELS) that uses the optical heterodyning principle is described. Vibration-related problems are considerably reduced because of the incorporation of all optical elements into one solid optical block. A real-time correlation analysis of the photocurrent fluctuations is performed by a PC-embedded analog-to-digital converter card with a digital signal processor. Investigation of the PSD in biological fluids for medical diagnostics is presented as a typical application. A diagnostic analysis of the PSD requires a simultaneous processing of a huge number of QELS data. An original statistical algorithm to accomplish this analysis has been developed. Technical specifications of instrumentation for heterodyne QELS measurement are discussed.

  8. The need for comparison of diagnostic dosemeters

    International Nuclear Information System (INIS)

    Kramer, H.M.

    1989-01-01

    One precondition for successfully implementing quality control in diagnostic radiology is that the measuring instruments used are of adequate quality. Among the measuring instruments used for quality control, dosemeters play a predominant role. Therefore it is essential to know the performance characteristics of a suitable dosemeter and to have information on the uncertainties and measurement errors found during acceptance testing. An outline will be given of the requirements on the accuracy of dosemeters. Such requirements have to address the task of the dosemeter and also take into account their technical feasibility. In order to gather information on the performance characteristics of field instruments, a programme for a European intercomparison has been developed which was carried out in 1988. The programme, together with its underlying ideas and its objectives, is presented in this paper. (author)

  9. The proposed Diagnostic Instrumentation and Analysis Laboratory, Mississippi State University

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1994-11-01

    The Department of Energy (DOE) proposes to authorize Mississippi State University (MSU) to proceed with the detailed design, construction and equipping of the proposed Diagnostic Instrumentation and Analysis Laboratory (DIAL). DOE grant funds are available to the University for the limited purpose of performing preliminary studies, including analysis necessary to conduct this environmental assessment. The proposed facility would be located in the Mississippi Research and Technology Park, adjacent to the Mississippi Agriculture and Forestry Experiment Station campus in Starkville, Mississippi. Total project cost is estimated at $7,953,600. This proposed laboratory would be designed to conduct research into combustion devices related to waste management and environmental restoration that is of importance to industry and government. The proposed facility`s role would be to develop diagnostic instrumentation capabilities in the area of combustion and related processes.

  10. A user interface on networked workstations for MFTF-B plasma diagnostic instruments

    International Nuclear Information System (INIS)

    Balch, T.R.; Renbarger, V.L.

    1986-01-01

    A network of Sun-2/170 workstations is used to provide an interface to the MFTF-B Plasma Diagnostics System at Lawrence Livermore National Laboratory. The Plasma Diagnostics System (PDS) is responsible for control of MFTF-B plasma diagnostic instrumentation. An EtherNet Local Area Network links the workstations to a central multiprocessing system which furnishes data processing, data storage and control services for PDS. These workstations permit a physicist to command data acquisition, data processing, instrument control, and display of results. The interface is implemented as a metaphorical desktop, which helps the operator form a mental model of how the system works. As on a real desktop, functions are provided by sheets of paper (windows on a CRT screen) called worksheets. The worksheets may be invoked by pop-up menus and may be manipulated with a mouse. These worksheets are actually tasks that communicate with other tasks running in the central computer system. By making entries in the appropriate worksheet, a physicist may specify data acquisition or processing, control a diagnostic, or view a result

  11. Comparing Diagnostic Accuracy of Cognitive Screening Instruments: A Weighted Comparison Approach

    Directory of Open Access Journals (Sweden)

    A.J. Larner

    2013-03-01

    Full Text Available Background/Aims: There are many cognitive screening instruments available to clinicians when assessing patients' cognitive function, but the best way to compare the diagnostic utility of these tests is uncertain. One method is to undertake a weighted comparison which takes into account the difference in sensitivity and specificity of two tests, the relative clinical misclassification costs of true- and false-positive diagnosis, and also disease prevalence. Methods: Data were examined from four pragmatic diagnostic accuracy studies from one clinic which compared the Mini-Mental State Examination (MMSE with the Addenbrooke's Cognitive Examination-Revised (ACE-R, the Montreal Cognitive Assessment (MoCA, the Test Your Memory (TYM test, and the Mini-Mental Parkinson (MMP, respectively. Results: Weighted comparison calculations suggested a net benefit for ACE-R, MoCA, and MMP compared to MMSE, but a net loss for TYM test compared to MMSE. Conclusion: Routine incorporation of weighted comparison or other similar net benefit measures into diagnostic accuracy studies merits consideration to better inform clinicians of the relative value of cognitive screening instruments.

  12. Développement d’un programme multidisciplinaire de diagnostic de l’adrénoleucodystrophie liée à l’X au Maroc: résultats de la mise en œuvre du programme de diagnostic clinique et biologique

    Science.gov (United States)

    Benjelloun, Fatima-Zohra Madani; Chabraoui, Layachi; Kriouile, Yamna

    2017-01-01

    Introduction L'adrénoleucodystrophie liée à l'X (X-ALD) est une maladie neurodégénérative sévère, due à des mutations du gène ABCD1. Elle se manifeste par une atteinte du système nerveux central et périphérique, une insuffisance surrénalienne et une atteinte des testicules chez le garçon. Son diagnostic repose sur le dosage des Acides Gras à Très Longue Chaine. Le diagnostic précoce est d'une grande importance puisque il définit l'accessibilité aux traitements selon le stage de la maladie. Méthodes Nous avons mis en place un programme de diagnostic de l'X-ALD au Maroc au niveau de l'Hôpital d'enfants et du Laboratoire centrale des maladies héréditaires et du métabolisme de Rabat. Le programme s'articule sur trois axes à savoir : le recrutement des patients, le diagnostic et la sensibilisation. Le diagnostic s'effectue selon trois protocoles : un protocole pour les cas symptomatiques, un deuxième pour les cas asymptomatiques et un troisième pour les femmes hétérozygotes. Résultats Durant trois ans après la mise en place de notre programme de diagnostic de l'Adrénoleucodystrophie liée à l'X, nous avons diagnostiqué la maladie chez sept familles, avec neuf garçons et trois femmes hétérozygotes. Tous les enfants diagnostiqués présentaient la forme cérébrale démyélinisante. Toutes les femmes hétérozygotes étaient asymptomatiques. Une prise en charge thérapeutique a été mise place selon la symptomatologie de chaque cas. Conclusion l'X-ALD est une maladie rare. Notre programme de diagnostique a permis de diagnostiquer un nombre important de cas, ce qui montre son importance. Les compagnes de sensibilisation auprès des professionnels permettront de mieux comprendre la maladie et mieux la diagnostiquer et ainsi donner accès à un nombre plus élevé de patients. PMID:29599883

  13. Strategies to Enhance Online Learning Teams. Team Assessment and Diagnostics Instrument and Agent-based Modeling

    Science.gov (United States)

    2010-08-12

    Strategies to Enhance Online Learning Teams Team Assessment and Diagnostics Instrument and Agent-based Modeling Tristan E. Johnson, Ph.D. Learning ...REPORT DATE AUG 2010 2. REPORT TYPE 3. DATES COVERED 00-00-2010 to 00-00-2010 4. TITLE AND SUBTITLE Strategies to Enhance Online Learning ...TeamsTeam Strategies to Enhance Online Learning Teams: Team Assessment and Diagnostics Instrument and Agent-based Modeling 5a. CONTRACT NUMBER 5b. GRANT

  14. Implementation of programmable logic controller for proposed new instrumentation and control system of RTP

    International Nuclear Information System (INIS)

    Mohd Khairulezwan Abdul Manan; Mohd Idris Taib; Mohd Dzul Aiman Aslan

    2010-01-01

    Reactor Monitoring System is one of very important part of Reactor Instrumentation and Control system. Current monitoring system is using analog system whereby all circuits are discrete circuit and all displays and indicators are not digitalized. The proposed new system will use using a Commercial Off-The-Shelf, state of the art, Supervisory Control and Data Acquisition system such as Programmable Logic Controller as well as Computer System. The implementations of Programmable Logic Controller are used for Data Acquisition System and as a sub-system for Computer System where all the activities involved are stored for operation record and report as well as use for research purposes. Programmable Logic Controller receives galvanised or optically isolated signal from Reactor Protection System. Programmable Logic Controller also receives signal from other parameters as a digital and analog input related to reactor system. (author)

  15. Emergency Diesel: Safety-related instrumentation and control with programmable logic controllers

    International Nuclear Information System (INIS)

    Breidenich, G.; Luedtke, M.

    2004-01-01

    This report presents a new concept for the design of emergency diesel equipment protection circuits as a part of the safety related instrumentation in the nuclear power plant Biblis, units A and B. The concept was implemented with state of the art SIMATIC S7/316 programmable logic controllers (PLCs) and can be adapted to any system with high availability requirements (e.g. power plant turbines, aircraft engines, mining pumps etc). (orig.)

  16. Validation of Existing Diagnosis of Autism in Mainland China Using Standardised Diagnostic Instruments

    Science.gov (United States)

    Sun, Xiang; Allison, Carrie; Auyeung, Bonnie; Zhang, Zhixiang; Matthews, Fiona E.; Baron-Cohen, Simon; Brayne, Carol

    2015-01-01

    Research to date in mainland China has mainly focused on children with autistic disorder rather than Autism Spectrum Conditions and the diagnosis largely depended on clinical judgment without the use of diagnostic instruments. Whether children who have been diagnosed in China before meet the diagnostic criteria of Autism Spectrum Conditions is not…

  17. Experience with diagnostic instrumentation in nuclear power plants

    International Nuclear Information System (INIS)

    Gopal, R.; Ciaramitaro, W.

    1977-01-01

    Over the past several years, Westinghouse has developed a coordinated system of on-line diagnostic instrumentation for the acquisition and analysis of data for diagnostics and incipient failure detection of critical plant equipment and systems. Primary motivation for this work is to improve NSSS availability and Maintainability through the detection of malfunctions at their inception. These systems encompass the following areas: (1) Vibration Monitoring System for detection of changes in vibrational characteristics of the major components of Nuclear Steam Supply System (NSSS) and Balance of Plant (BOP); (2) Acoustic Monitoring System for detection and location of leaks in the primary system pressure boundary and other piping systems in PWRs; (3) Metal Impact Monitoring for detection of loose debris in the reactor vessel and steam generators; (4) Nuclear Noise Monitoring System for monitoring core barrel vibration; (5) Sensor Response Time Measurement System for detecting any degradation of process sensors; and (6) Transit Time Flow Meter for determining primary coolant flow rate. Summarized in this paper are some of the features of the systems and in-plant experience. These experiences demonstrate that diagnostic systems in combination with analytical and laboratory work for data interpretation do improve plant availability. (author)

  18. Use of the virtual instrument technology in complex diagnostics of marine electrical equipment

    Directory of Open Access Journals (Sweden)

    Ivlev M. L.

    2017-12-01

    Full Text Available The assessment of the most informative methods of diagnostics of mechanisms with electric drive has been given; their realization in a measuring complex on the basis of the virtual device has been considered. The comparative analysis of vibration methods for the analysis of current spectra and the thermal method of nondestructive testing has been carried out. It has been stated that methods of vibration diagnostics are more sensitive to defects in the mechanical part of the electric drive (determination of defects in bearing assemblies, misalignment of shafts, imbalance of rotating parts. Analysis of the current spectrum at the early stage has shown the defects of rotor windings, static and dynamic rotor eccentricity. The temperature of the bearing assemblies and the stator (the thermal control method indicates the defects in lubrication and cooling systems. The set of methods of nondestructive control allows increase the completeness and reliability of diagnosis of the mechanism with electric drive. The optimal solution to realize into one measuring instrument all methods of diagnostics is to use the technology of virtual instruments. The list of components for the measuring part of the complex and the functional scheme of the program for processing the results have been given. Spectra of vibration of defective mechanisms have been obtained with the help of the measuring complex based on the virtual instrument. Some recommendations have been given on the introduction of the virtual appliance in the State register of measuring instruments.

  19. Programmable Input Mode Instrumentation Amplifier Using Multiple Output Current Conveyors

    Directory of Open Access Journals (Sweden)

    Pankiewicz Bogdan

    2017-03-01

    Full Text Available In this paper a programmable input mode instrumentation amplifier (IA utilising second generation, multiple output current conveyors and transmission gates is presented. Its main advantage is the ability to choose a voltage or current mode of inputs by setting the voltage of two configuration nodes. The presented IA is prepared as an integrated circuit block to be used alone or as a sub-block in a microcontroller or in a field programmable gate array (FPGA, which shall condition analogue signals to be next converted by an analogue-to-digital converter (ADC. IA is designed in AMS 0.35 µm CMOS technology and the power supply is 3.3 V; the power consumption is approximately 9.1 mW. A linear input range in the voltage mode reaches ± 1.68 V or ± 250 µA in current mode. A passband of the IA is above 11 MHz. The amplifier works in class A, so its current supply is almost constant and does not cause noise disturbing nearby working precision analogue circuits.

  20. Scientific programme and manufacture of types DK-1 and DK-2 diagnostic assemblies

    International Nuclear Information System (INIS)

    Krett, V.; Kott, J.; Vlcek, J.; Mlady, Z.

    1980-01-01

    The programme is described of measurements to be effected on the Rheinsberg WWER-2 reactor using diagnostic assemblies DK-1 and DK-2. The DK-1 assemblies were manufactured in the USSR and tested in the big water loop at SKODA Works. The insertion of the assemblies in the reactor is being prepared. The DK-2 assemblies are developed by SKODA Works in cooperation with the USSR, Hungary and Poland. (Ha)

  1. Machine and plasma diagnostic instrumentation systems for the Tandem Mirror Experiment Upgrade

    International Nuclear Information System (INIS)

    Coutts, G.W.; Coffield, F.E.; Lang, D.D.; Hornady, R.S.

    1981-01-01

    To evaluate performance of a second generation Tandem Mirror Machine, an extensive instrumentation system is being designed and installed as part of the major device fabrication. The systems listed will be operational during the start-up phase of the TMX Upgrade machine and provide bench marks for future performance data. In addition to plasma diagnostic instrumentation, machine parameter monitoring systems will be installed prior to machine operation. Simultaneous recording of machine parameters will permit evaluation of plasma parameters sensitive to machine conditions

  2. Calibration methodology for instruments utilized in X radiation beams, diagnostic level

    International Nuclear Information System (INIS)

    Penha, M. da; Potiens, A.; Caldas, L.V.E.

    2004-01-01

    Methodologies for the calibration of diagnostic radiology instruments were established at the Calibration Laboratory of IPEN. The methods may be used in the calibration procedures of survey meters used in radiation protection measurements (scattered radiation), instruments used in direct beams (attenuated and non attenuated beams) and quality control instruments. The established qualities are recommended by the international standards IEC 1267 and ISO 4037-3. Two ionization chambers were used as reference systems, one with a volume of 30 cm 3 for radiation protection measurements, and the other with a volume of 1 cm 3 for direct beam measurements. Both are traceable to the German Primary Laboratory of Physikalisch-Technische Bundesanstalt (PTB). In the case of calibration of quality control instruments, a non-invasive method using the measurement of the spectrum endpoint was established with a portable gamma and X-ray Intertechnique spectrometer system. The methods were applied to survey meters (radiation protection measurements), ionization chambers (direct beam measurements) and k Vp meters (invasive and non-invasive instruments). (Author)

  3. Calibration methodology for instruments utilized in X radiation beams, diagnostic level

    Energy Technology Data Exchange (ETDEWEB)

    Penha, M. da; Potiens, A.; Caldas, L.V.E. [Instituto de Pesquisas Energeticas e Nucleares, Comissao Nacional de Energia Nuclear, Sao Paulo (Brazil)]. E-mail: mppalbu@ipen.br

    2004-07-01

    Methodologies for the calibration of diagnostic radiology instruments were established at the Calibration Laboratory of IPEN. The methods may be used in the calibration procedures of survey meters used in radiation protection measurements (scattered radiation), instruments used in direct beams (attenuated and non attenuated beams) and quality control instruments. The established qualities are recommended by the international standards IEC 1267 and ISO 4037-3. Two ionization chambers were used as reference systems, one with a volume of 30 cm{sup 3} for radiation protection measurements, and the other with a volume of 1 cm{sup 3} for direct beam measurements. Both are traceable to the German Primary Laboratory of Physikalisch-Technische Bundesanstalt (PTB). In the case of calibration of quality control instruments, a non-invasive method using the measurement of the spectrum endpoint was established with a portable gamma and X-ray Intertechnique spectrometer system. The methods were applied to survey meters (radiation protection measurements), ionization chambers (direct beam measurements) and k Vp meters (invasive and non-invasive instruments). (Author)

  4. The efficacy of the personality diagnostic questionnaire-revised as a diagnostic screening instrument in an anxiety disorder group

    NARCIS (Netherlands)

    van Velzen, CJM; Luteijn, F; Scholing, A; van Hout, WJPJ; Emmelkamp, PMG

    1999-01-01

    The efficacy of the Personality Diagnostic Questionnaire - Revised (PDQ-R) as a screening instrument was examined in a sample of 137 anxious outpatients. The SCID-II was used as the criterion. The PDQ-R cut-offs were adjusted until the maximum kappa agreement for each scale was reached. The results

  5. Establish radiation protection programme for diagnostic radiology

    International Nuclear Information System (INIS)

    Mboya, G.

    2014-01-01

    Mammography is an effective method used for breast diagnostics and screening. The aim of this project is to review the literature on how to establish radiation protection programme for mammography in order to protect the patients, the occupationally exposed workers and the members of the public from harmful effects of ionizing radiation. It reviews some of the trends in mammography doses and dosimetric principles such as average glandular dose in the glandular tissue which is used for description of radiation risk, also the factors affecting patient doses are discussed. However, the average glandular dose should not be used directly to estimate the radiation risk from mammography. Risk is calculated under certain assumptions from determined entrance surface air kerma. Given the increase in population dose, emphasis is placed on the justification and optimization of the mammographic procedures. Protection is optimized by the radiation dose being appropriate with the purpose of the mammographic examination. The need to establish diagnostic reference levels as an optimization is also discussed. In order to obtain high quality mammograms at low dose to the breast, it is necessary to use the correct equipment and perform periodic quality control tests on mammography equipment. It is noted that in order to achieve the goal of this project, the application of radiation protection should begin at the time of requesting for mammography examination, positioning of the patient, irradiation, image processing and interpretation of mammogram. It is recommended that close cooperation between radiology technologists, radiologist, medical physicists, regulatory authority and other support workers be required and established to obtain a consistent and effective level of radiation protection in a mammography facility. (author)

  6. Experiences with 'on-line' diagnostic instrumentation in nuclear power plants

    International Nuclear Information System (INIS)

    Gopal, R.; Ciaramitaro, W.; Smith, J.R.

    1981-01-01

    Over the past several years, Westinghouse has developed a coordinated system of on-line diagnostic instrumentation for the acquisition and analysis of data for diagnostics and incipient failure detection of critical plant equipment and systems. Primary motivation for this work is to improve Nuclear Steam Supply System (NSSS) availability and maintainability through the detection of malfunctions at their inception. These systems include: 1) Acoustic leak monitoring for detection and location of leaks in the primary system pressure boundary and other piping systems in PWR's; 2) Metal impact monitoring for detection of loose debris in the reactor vessel and steam generators; 3) Nuclear noise monitoring for monitoring core barrel vibration. Summarized in this paper are some of the features of the systems and inplant experience. (author)

  7. Multi-hybrid instrumentations with smartphones and smartpads for innovative in-field and POC diagnostics

    Science.gov (United States)

    Hofmann, Dietrich; Dittrich, Paul-Gerald; Gärtner, Claudia; Klemm, Richard

    2013-03-01

    Aim of the paper is the orientation of research and development on a completely new approach to innovative in-field and point of care diagnostics in industry, biology and medicine. Central functional modules are smartphones and/or smart pads supplemented by additional hardware apps and software apps. Specific examples are given for numerous practical applications concerning optodigital instrumentations. The methodical classification distinguishes between different levels for combination of hardware apps (hwapps) and software apps (swapps) with smartphones and/or smartpads. These methods are fundamental enablers for the transformation from stationary conventional laboratory diagnostics into mobile innovative in-field and point of care diagnostics. The innovative approach opens so far untapped enormous markets due to the convenience, reliability and affordability of smartphone and/or smartpad instruments. A highly visible advantage of smartphones and/or smartpads is the huge number of their distribution, their worldwide connectivity via cloud services and the experienced capability of their users for practical operations.

  8. Digital Instrumentation and Control working group (DICWG) - MDEP DICWG Programme Plan 2012 2013

    International Nuclear Information System (INIS)

    2012-02-01

    The Multinational Design Evaluation Programme (MDEP) Digital Instrumentation and Controls Working Group (DICWG) was approved by MDEP's Policy Group in March 2008 and meets approximately 3 times a year. All MDEP members and the IAEA are invited to participate in this working group's activities. The DICWG's main objectives are as follows: - to document common positions in the DI and C safety systems design areas; - to harmonise and converge national codes, standards and regulatory requirements and practices in this area while recognising the sovereign rights and responsibilities of national regulators in carrying out their safety reviews of new reactor designs (see the DICWG programme plan for more details of the group's work). The DICWG interacts regularly with the following organisations: - IEC (International Electro-technical Commission) Subcommittee 45A, Instrumentation and Control of Nuclear Facilities; - IEEE (Institute of Electric and Electronics Engineers); - other organisations involved in the design of digital I and C safety systems for nuclear power plants. The DICWG reports its status to the MDEP Steering Technical Committee at the latter's thrice annual meetings. This document presents the 2012 and 2013 programme plan and its products: the Generic Common Position DICWG-02 on Software Tools; the Generic Common Position DICWG-03 on Verification and Validation throughout the Life Cycle of Safety Systems Using Digital Computers; the Generic Common Position DICWG-04 on Communication Independence; the Generic Common Position DICWG-05 on Treatment of Hardware Description Language (HDL) Programmed Devices for Use in Nuclear Safety Systems; the Generic Common Position DICWG-06 on Simplicity in Design; the Generic Common Position DICWG-08 on Impact of Cyber Security Features on Digital I and C Safety Systems

  9. Mandatory quality assurance programmes for diagnostic radiology facilities in Ontario, Canada

    International Nuclear Information System (INIS)

    Rainbow, A.J.

    1989-01-01

    Regulations made under the Healing Arts Radiation Protection (HARP) Act, Government of Ontario, Canada, were promulgated in the form of a safety Code in November, 1985. These regulations require a minimum technical quality assurance (QA) programme for all diagnostic radiology facilities in the Province. The mandatory QA programme requires certain tests and procedures to be carried out at specified intervals. The tests include photographic quality control, patient entrance exposure measurement, collimation, half-value layer, phototiming parameters, fluoroscopic parameters including maximum patient entrance exposure rate, resolution, limit timer and automatic brightness control, and tomographic parameters including fulcrum accuracy, thickness of cut and mechanical stability. Records of the results of these tests must be kept for at least 6 years. A set of HARP guidelines published in June 1987 includes a description of appropriate measuring methods for each test together with a set of forms for recording the results of such tests. The regulations specify limiting values for a number of equipment performance parameters, including the maximum allowable patient skin entrance exposure values for common radiographic projections. (author)

  10. Dental diagnostic clinical instrument (Canary) development using photothermal radiometry and modulated luminescence

    International Nuclear Information System (INIS)

    Jeon, R J; Sivagurunathan, K; Garcia, J; Matvienko, A; Mandelis, A; Abrams, S

    2010-01-01

    Since 1999, our group at the CADIFT, University of Toronto, has developed the application of Frequency Domain Photothermal Radiometry (PTR) and Luminescence (LUM) to dental caries detection. Various cases including artificial caries detection have been studied and some of the inherent advantages of the adaptation of this technique to dental diagnostics in conjunction with modulated luminescence as a dual-probe technique have been reported. Based on these studies, a portable, compact diagnostic instrument for dental clinic use has been designed, assembled and tested. A semiconductor laser, optical fibers, a thermoelectric cooled mid-IR detector, and a USB connected data acquisition card were used. Software lock-in amplifier techniques were developed to compute amplitude and phase of PTR and LUM signals. In order to achieve fast measurement and acceptable signal-to-noise ratio (SNR) for clinical application, swept sine waveforms were used. As a result sampling and stabilization time for each measurement point was reduced to a few seconds. A sophisticated software interface was designed to simultaneously record intra-oral camera images with PTR and LUM responses. Preliminary results using this instrument during clinical trials in a dental clinic showed this instrument could detect early caries both from PTR and LUM signals.

  11. GPIB based instrumentation and control system for ADITYA Thomson Scattering Diagnostic

    Energy Technology Data Exchange (ETDEWEB)

    Patel, Kiran, E-mail: kkpatel@ipr.res.in; Pillai, Vishal; Singh, Neha; Chaudhary, Vishnu; Thomas, Jinto; Kumar, Ajai

    2016-11-15

    The ADITYA Thomson Scattering Diagnostic is a single point Ruby laser based system with a spectrometer for spectral dispersion and photomultiplier tubes for the detection of scattered light. The system uses CAMAC (Computer Automated Measurement And Control) based control and data acquisition system, which synchronizes the Ruby laser, detectors and the digitizer. Previously used serial based CAMAC controller is upgraded to GPIB (General Purpose Interface Bus) based CAMAC controller for configuration and data transfer. The communication protocols for different instruments are converted to a single GPIB based for better interface. The entire control and data acquisition program is developed on LabVIEW platform for versatile operation of diagnostics with improved user friendly GUI (Graphical User Interfaces) and allows user to remotely update the laser firing time with respect to the plasma shot. The software is in handshake with the Tokamak main control program through network to minimize manual interventions for the operation of the diagnostics. The upgraded system improved the performance of the diagnostics in comparison to earlier in terms of better data transmission rate, easy to maintain and program is upgradable.

  12. GPIB based instrumentation and control system for ADITYA Thomson Scattering Diagnostic

    International Nuclear Information System (INIS)

    Patel, Kiran; Pillai, Vishal; Singh, Neha; Chaudhary, Vishnu; Thomas, Jinto; Kumar, Ajai

    2016-01-01

    The ADITYA Thomson Scattering Diagnostic is a single point Ruby laser based system with a spectrometer for spectral dispersion and photomultiplier tubes for the detection of scattered light. The system uses CAMAC (Computer Automated Measurement And Control) based control and data acquisition system, which synchronizes the Ruby laser, detectors and the digitizer. Previously used serial based CAMAC controller is upgraded to GPIB (General Purpose Interface Bus) based CAMAC controller for configuration and data transfer. The communication protocols for different instruments are converted to a single GPIB based for better interface. The entire control and data acquisition program is developed on LabVIEW platform for versatile operation of diagnostics with improved user friendly GUI (Graphical User Interfaces) and allows user to remotely update the laser firing time with respect to the plasma shot. The software is in handshake with the Tokamak main control program through network to minimize manual interventions for the operation of the diagnostics. The upgraded system improved the performance of the diagnostics in comparison to earlier in terms of better data transmission rate, easy to maintain and program is upgradable.

  13. Beam diagnostics based on virtual instrument technology for HLS

    International Nuclear Information System (INIS)

    Sun Baogen; Lu Ping; Wang Xiaohui; Wang Baoyun; Wang Junhua; Gu Liming; Fang Jia; Ma Tianji

    2009-01-01

    The paper introduce the beam diagnostics system using virtual instrument technology for Hefei Light Source (HLS), which includes a GPIB bus-based DCCT measurement system to measure the beam DC current and beam life, a VXIbus-based closed orbit measurement system to measure the beam position, a PCIbus-based beam profile measurement system to measure the beam profile and emittance, a GPIB-LAN based bunch length system using photoelectric method, and a Ethernet-based photon beam position measurement system. The software is programmed by LabVIEW, which reduces much developing work. (authors)

  14. Cold vacuum chamber for diagnostics: Instrumentation and first results

    Directory of Open Access Journals (Sweden)

    S. Gerstl

    2014-10-01

    Full Text Available For a proper design of the cryogenic layout of superconducting insertion devices it is necessary to take into account the heat load from the beam to the cold beam tube. In order to measure and possibly understand the beam heat load to a cold bore, a cold vacuum chamber for diagnostics (COLDDIAG has been built. COLDDIAG is designed in a flexible way, to allow its installation in different light sources. In order to study the beam heat load and the influence of the cryosorbed gas layer, the instrumentation comprises temperature sensors, pressure gauges, and mass spectrometers as well as retarding field analyzers with which it is possible to measure the beam heat load, total pressure, and gas content as well as the flux of particles hitting the chamber walls. In this paper we describe the experimental equipment, the installation of COLDDIAG in the Diamond Light Source and selected examples of the measurements performed to show the capabilities of this unique instrument.

  15. Cold vacuum chamber for diagnostics: Instrumentation and first results

    Science.gov (United States)

    Gerstl, S.; Voutta, R.; Casalbuoni, S.; Grau, A. W.; Holubek, T.; de Jauregui, D. Saez; Bartolini, R.; Cox, M. P.; Longhi, E. C.; Rehm, G.; Schouten, J. C.; Walker, R. P.; Sikler, G.; Migliorati, M.; Spataro, B.

    2014-10-01

    For a proper design of the cryogenic layout of superconducting insertion devices it is necessary to take into account the heat load from the beam to the cold beam tube. In order to measure and possibly understand the beam heat load to a cold bore, a cold vacuum chamber for diagnostics (COLDDIAG) has been built. COLDDIAG is designed in a flexible way, to allow its installation in different light sources. In order to study the beam heat load and the influence of the cryosorbed gas layer, the instrumentation comprises temperature sensors, pressure gauges, and mass spectrometers as well as retarding field analyzers with which it is possible to measure the beam heat load, total pressure, and gas content as well as the flux of particles hitting the chamber walls. In this paper we describe the experimental equipment, the installation of COLDDIAG in the Diamond Light Source and selected examples of the measurements performed to show the capabilities of this unique instrument.

  16. Results of evaluation of quality control measurement instrument of x-ray diagnostic equipment by non-invasive method

    International Nuclear Information System (INIS)

    Laan, Flavio T. van der; Elbern, Alvin W.

    1996-01-01

    This work shows the results of the tests realized on Santa Rita Hospital (Porto Alegre), using a non invasive quality control measurement instrument, developed in this University for fast measurement of essential parameters of X-rays diagnostic equipment. In the tests we used a diagnostics Siemens X ray, model Heliofos 4E as our standard equipment. The linearity test of sensor probe and the exposure rate calibration was performed, with a Palmer Dosimeter. For the kVp and exposure time we used a RTI commercial instrument. (author)

  17. Evaluating disease management programme effectiveness: an introduction to instrumental variables.

    Science.gov (United States)

    Linden, Ariel; Adams, John L

    2006-04-01

    This paper introduces the concept of instrumental variables (IVs) as a means of providing an unbiased estimate of treatment effects in evaluating disease management (DM) programme effectiveness. Model development is described using zip codes as the IV. Three diabetes DM outcomes were evaluated: annual diabetes costs, emergency department (ED) visits and hospital days. Both ordinary least squares (OLS) and IV estimates showed a significant treatment effect for diabetes costs (P = 0.011) but neither model produced a significant treatment effect for ED visits. However, the IV estimate showed a significant treatment effect for hospital days (P = 0.006) whereas the OLS model did not. These results illustrate the utility of IV estimation when the OLS model is sensitive to the confounding effect of hidden bias.

  18. The Application and Evaluation of a Two-Concept Diagnostic Instrument with Students Entering College General Chemistry

    Science.gov (United States)

    Heredia, Keily; Xu, Xiaoying; Lewis, Jennifer E.

    2012-01-01

    The Particulate Nature of Matter and Chemical Bonding Diagnostic Instrument (Othman J., Treagust D. F. and Chandrasegaran A. L., (2008), "Int. J. Sci. Educ.," 30(11), 1531-1550) is used to investigate college students' understanding of two chemistry concepts: particulate nature of matter and chemical bonding. The instrument, originally…

  19. The influence of parental concern on the utility of autism diagnostic instruments.

    Science.gov (United States)

    Havdahl, Karoline Alexandra; Bishop, Somer L; Surén, Pål; Øyen, Anne-Siri; Lord, Catherine; Pickles, Andrew; von Tetzchner, Stephen; Schjølberg, Synnve; Gunnes, Nina; Hornig, Mady; Lipkin, W Ian; Susser, Ezra; Bresnahan, Michaeline; Magnus, Per; Stenberg, Nina; Reichborn-Kjennerud, Ted; Stoltenberg, Camilla

    2017-10-01

    The parental report-based Autism Diagnostic Interview-Revised (ADI-R) and the clinician observation-based Autism Diagnostic Observation Schedule (ADOS) have been validated primarily in U.S. clinics specialized in autism spectrum disorder (ASD), in which most children are referred by their parents because of ASD concern. This study assessed diagnostic agreement of the ADOS-2 and ADI-R toddler algorithms in a more broadly based sample of 679 toddlers (age 35-47 months) from the Norwegian Mother and Child Cohort. We also examined whether parental concern about ASD influenced instrument performance, comparing toddlers identified based on parental ASD concern (n = 48) and parent-reported signs of developmental problems (screening) without a specific concern about ASD (n = 400). The ADOS cutoffs showed consistently well-balanced sensitivity and specificity. The ADI-R cutoffs demonstrated good specificity, but reduced sensitivity, missing 43% of toddlers whose parents were not specifically concerned about ASD. The ADI-R and ADOS dimensional scores agreed well with clinical diagnoses (area under the curve ≥ 0.85), contributing additively to their prediction. On the ADI-R, different cutoffs were needed according to presence or absence of parental ASD concern, in order to achieve comparable balance of sensitivity and specificity. These results highlight the importance of taking parental concern about ASD into account when interpreting scores from parental report-based instruments such as the ADI-R. While the ADOS cutoffs performed consistently well, the additive contributions of ADI-R and ADOS scores to the prediction of ASD diagnosis underscore the value of combining instruments based on parent accounts and clinician observation in evaluation of ASD. Autism Res 2017, 10: 1672-1686. © 2017 International Society for Autism Research, Wiley Periodicals, Inc. © 2017 International Society for Autism Research, Wiley Periodicals, Inc.

  20. Validation of existing diagnosis of autism in mainland China using standardised diagnostic instruments

    Science.gov (United States)

    Sun, Xiang; Allison, Carrie; Auyeung, Bonnie; Zhang, Zhixiang; Matthews, Fiona E; Baron-Cohen, Simon; Brayne, Carol

    2016-01-01

    Research to date in mainland China has mainly focused on children with autistic disorder rather than Autism Spectrum Conditions and the diagnosis largely depended on clinical judgment without the use of diagnostic instruments. Whether children who have been diagnosed in China before meet the diagnostic criteria of Autism Spectrum Conditions is not known nor how many such children would meet these criteria. The aim of this study was to evaluate children with a known diagnosis of autism in mainland China using the Autism Diagnostic Observation Schedule and the Autism Diagnostic Interview–Revised to verify that children who were given a diagnosis of autism made by Chinese clinicians in China were mostly children with severe autism. Of 50 children with an existing diagnosis of autism made by Chinese clinicians, 47 children met the diagnosis of autism on the Autism Diagnostic Observation Schedule algorithm and 44 children met the diagnosis of autism on the Autism Diagnostic Interview–Revised algorithm. Using the Gwet’s alternative chance-corrected statistic, the agreement between the Chinese diagnosis and the Autism Diagnostic Observation Schedule diagnosis was very good (AC1 = 0.94, p diagnosis and the Autism Diagnostic Interview–Revised (AC1 = 0.91, p Autism Diagnostic Observation Schedule and the Autism Diagnostic Interview–Revised was lower but still very good (AC1 = 0.83, p < 0.005). PMID:25757721

  1. Coordinated research programme on radiation protection in diagnostic radiology in Asia and the Far East

    International Nuclear Information System (INIS)

    Le Heron, J.

    1997-01-01

    Ten Asian countries (China, Vietnam, Thailand, Bangladesh, India, Pakistan, Iran, Philipppines, Malaysia, and Indonesia) are currently participating in a three year programme, as part of a Coordinated Research Programme of the International Atomic Energy Agency, aimed at reducing patient doses in diagnostic radiology through the implementation of optimisation of radiation protection. At the first meeting, held in Manila in September 1995, the project protocol was formulated for the first eighteen months of the programme, where the focus was on plain film radiography. The purpose of the second meeting was to briefly review the first half of the project, and to then come up with protocols for the second phase, where the attention was on dose reduction in fluoroscopic procedures and CT procedures. The second Research Coordination Meeting, held in Manila 3-7 March, was attended by participants from all the countries, with the exception of Iran, plus a consultant from each of Italy and New Zealand, and the scientific secretary from IAEA, Vienna. If the obvious enthusiasm of the participants is able to b maintained on return to their respective countries, then the signs are very healthy for a successful second phase of the programme. (author)

  2. Diagnostic performance of major depression disorder case-finding instruments used among mothers of young children in the United States: A systematic review.

    Science.gov (United States)

    Owora, Arthur H; Carabin, Hélène; Reese, Jessica; Garwe, Tabitha

    2016-09-01

    Growing recognition of the interrelated negative outcomes associated with major depression disorder (MDD) among mothers and their children has led to renewed public health interest in the early identification and treatment of maternal MDD. Healthcare providers, however, remain unsure of the validity of existing case-finding instruments. We conducted a systematic review to identify the most valid maternal MDD case-finding instrument used in the United States. We identified articles reporting the sensitivity and specificity of MDD case-finding instruments based on Diagnostic and Statistical Manual of Mental Disorders, Fourth Edition (DSM-IV) by systematically searching through three electronic bibliographic databases, PubMed, PsycINFO, and EMBASE, from 1994 to 2014. Study eligibility and quality were evaluated using the Standards for the Reporting of Diagnostic Accuracy studies and Quality Assessment of Diagnostic Accuracy Studies guidelines respectively. Overall, we retrieved 996 unduplicated articles and selected 74 for full-text review. Of these, 14 articles examining 21 different instruments were included in the systematic review. The 10 item Edinburgh Postnatal Depression Scale and Postpartum Depression Screening Scale had the most stable (lowest variation) and highest diagnostic performance during the antepartum and postpartum periods (sensitivity range: 0.63-0.94 and 0.67-0.95; specificity range: 0.83-0.98 and 0.68-0.97 respectively). Greater variation in diagnostic performance was observed among studies with higher MDD prevalence. Factors that explain greater variation in instrument diagnostic performance in study populations with higher MDD prevalence were not examined. Findings suggest that the diagnostic performance of maternal MDD case-finding instruments is peripartum period-specific. Published by Elsevier B.V.

  3. DIPAC 2005 7. European workshop on beam diagnostics and instrumentation for particle accelerators

    International Nuclear Information System (INIS)

    2005-01-01

    Accelerators can not be improved without the development of adequate beam instruments and diagnostic tools. This year this statement is particularly right: a lot of contributions are dedicated to beam monitoring and to the design of new beam monitors based on original technologies. This document gathers about 100 contributions

  4. DIPAC 2005 7. European workshop on beam diagnostics and instrumentation for particle accelerators

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2005-07-01

    Accelerators can not be improved without the development of adequate beam instruments and diagnostic tools. This year this statement is particularly right: a lot of contributions are dedicated to beam monitoring and to the design of new beam monitors based on original technologies. This document gathers about 100 contributions.

  5. Current state of a dosimetric evaluation programme in diagnostic radiology installations in Spain

    International Nuclear Information System (INIS)

    Vano, E.; Gonzalez, L.; Calzado, A.; Delgado, V.; Moran, P.; Sanchez, B.; Murias, F.

    1988-01-01

    The Medical Physics Group at the School of Medicine of the Complutense University of Madrid, started a programme on the study of radiation doses in relation to Diagnostic Radiology in the area of Madrid in 1986, in cooperation with the Department of Health and Consumer Affairs, and several Madrid area hospitals as well as some Outpatient Centers. In Spain, the National Health Service (NHS) (through the National Institute of Health, INSALUD), potentially cares for the health of approximately 94% of the population. This figure reaches 99% at the Community of Madrid. Radiological examinations are performed mainly in Hospitals and Outpatient Centers (the latter making up a first link in the patient's radiological diagnosis). Private Diagnostic Radiology is used by the remaining 6% of the population (not taking into account the population attended in military hospitals), and by patients who in spite of having access to NHS Diagnostic Radiology Services, prefer to choose the private sector for different reasons. Besides the data we obtained during the first year of study from four large Madrid-area hospitals (and a few outpatient centers); we have used data furnished by the Department of Health and Consumer Affairs, the INSALUD and other sources

  6. Use of spreadsheets for interactive control of MFTF-B plasma diagnostic instruments

    International Nuclear Information System (INIS)

    Preckshot, G.G.; Goldner, A.L.; Kobayashi, A.

    1986-01-01

    The Mirror Fusion Test Facility (MFTF-B) at Lawrence Livermore National Laboratory has a variety of highly individualized plasma diagnostic instruments attached to the experiment. These instruments are controlled through graphics workstations networked to a central computer system. A distributed spreadsheet-like program runs in both the graphics workstations and in the central computer system. An interface very similar to a commercial spreadsheet program is presented to the user at a workstation. In a commercial spreadsheet program, the user may attach mathematical calculation functions to spreadsheet cells. At MFTF-B, hardware control functions, hardware monitoring functions, and communications functions, as well as mathematical functions, may be attached to cells. Both the user and feedback from instrument hardware may make entries in spreadsheet cells; any entry in a spreadsheet cell may cause reevaluation of the cell's associated functions. The spreadsheet approach makes the addition of a new instrument a matter of designing one or more spreadsheet tables with associated meta-language-defined control and communication function strings. This paper describes the details of the spreadsheets and the implementation experience

  7. Use of spreadsheets for interactive control of MFTF-B plasma diagnostic instruments

    International Nuclear Information System (INIS)

    Preckshot, G.G.; Goldner, A.; Kobayashi, A.

    1985-01-01

    The Mirror Fusion Test Facility (MFTF-B) at Lawrence Livermore National Laboratory has a variety of highly individualized plasma diagnostic instruments attached to the experiment. These instruments are controlled through graphics workstations networked to a central computer system. A distributed spreadsheet-like program runs in both the graphics workstations and in the central computer system. An interface very similar to a commercial spreadsheet program is presented to the user at a workstation. In a commercial spreadsheet program, the user may attach mathematical calculation functions to spreadsheet cells. At MFTF-B, hardware control functions, hardware monitoring functions, and communications functions, as well as mathematical functions, may be attached to cells. Both the user and feedback from instrument hardware may make entries in spreadsheet cells; any entry in a spreadsheet cell may cause reevaluation of the cell's associated functions. The spreadsheet approach makes the addition of a new instrument a matter of designing one or more spreadsheet tables with associated meta-language-defined control and communication function strings. We report here details of our spreadsheets and our implementation experience

  8. Development of diagnostic test instruments to reveal level student conception in kinematic and dynamics

    Science.gov (United States)

    Handhika, J.; Cari, C.; Suparmi, A.; Sunarno, W.; Purwandari, P.

    2018-03-01

    The purpose of this research was to develop a diagnostic test instrument to reveal students' conceptions in kinematics and dynamics. The diagnostic test was developed based on the content indicator the concept of (1) displacement and distance, (2) instantaneous and average velocity, (3) zero and constant acceleration, (4) gravitational acceleration (5) Newton's first Law, (6) and Newton's third Law. The diagnostic test development model includes: Diagnostic test requirement analysis, formulating test-making objectives, developing tests, checking the validity of the content and the performance of reliability, and application of tests. The Content Validation Index (CVI) results in the category are highly relevant, with a value of 0.85. Three questions get negative Content Validation Ratio CVR) (-0.6), after revised distractors and clarify visual presentation; the CVR become 1 (highly relevant). This test was applied, obtained 16 valid test items, with Cronbach Alpha value of 0.80. It can conclude that diagnostic test can be used to reveal the level of students conception in kinematics and dynamics.

  9. Psychometric properties of the motor diagnostics in the German football talent identification and development programme.

    Science.gov (United States)

    HÖner, Oliver; Votteler, Andreas; Schmid, Markus; Schultz, Florian; Roth, Klaus

    2015-01-01

    The utilisation of motor performance tests for talent identification in youth sports is discussed intensively in talent research. This article examines the reliability, differential stability and validity of the motor diagnostics conducted nationwide by the German football talent identification and development programme and provides reference values for a standardised interpretation of the diagnostics results. Highly selected players (the top 4% of their age groups, U12-U15) took part in the diagnostics at 17 measurement points between spring 2004 and spring 2012 (N = 68,158). The heterogeneous test battery measured speed abilities and football-specific technical skills (sprint, agility, dribbling, ball control, shooting, juggling). For all measurement points, the overall score and the speed tests showed high internal consistency, high test-retest reliability and satisfying differential stability. The diagnostics demonstrated satisfying factorial-related validity with plausible and stable loadings on the two empirical factors "speed" and "technical skills". The score, and the technical skills dribbling and juggling, differentiated the most among players of different performance levels and thus showed the highest criterion-related validity. Satisfactory psychometric properties for the diagnostics are an important prerequisite for a scientifically sound rating of players' actual motor performance and for the future examination of the prognostic validity for success in adulthood.

  10. Instrument to synchronize Thomson scattering diagnostic measurements with MHD acitivity in a tokamak

    International Nuclear Information System (INIS)

    Wintenberg, A.L.

    1985-04-01

    An instrument to synchronize the firing of a ruby laser for a Thomson scattering diagnostic with plasma oscillations was designed, developed, and evaluated. The instrument will fire the laser at a user-selected phase of an input sine or sawtooth wave with an accuracy of +-15 0 . Allowable frequencies range from 20 to 500 Hz for a sawtooth and from 1 to 30 kHz for a sine wave. The instrument also allows synchronization with a sine wave to be enabled by a preselected sawtooth phase. The instrument uses analog signal processing circuits to separate the signal components, remove unwanted components, and produce zero-phase synchronization pulses. The instrument measures the period between zero-phase pulses in order to produce phase synchronization pulses delayed a fraction of the period from the zero-phase pulses. The laser is fired by the phase synchronization pulse. Unwanted signal components are attenuated by bandpass filters. A digitally controlled self-adjusting bandpass filter for sine processing. The instrument was used to investigate the variation of the electron temperature profile with the phase of the x-ray signal from an Impurity Studies Experiment (ISX-B) plasma exhibiting magnetohydrodynamic (MHD) activity

  11. Dental diagnostic clinical instrument ('Canary') development using photothermal radiometry and modulated luminescence

    Energy Technology Data Exchange (ETDEWEB)

    Jeon, R J; Sivagurunathan, K; Garcia, J; Matvienko, A; Mandelis, A [Center for Advanced Diffusion Wave Technologies (CADIFT), Department of Mechanical and Industrial Engineering, University of Toronto, 5 King' s College Road, Toronto, Ontario, M5S 3G8 (Canada); Abrams, S, E-mail: mandelis@mie.utoronto.c [Quantum Dental Technologies, 748 Briar Hill Avenue, Toronto, Ontario, M6B 1L3 (Canada)

    2010-03-01

    Since 1999, our group at the CADIFT, University of Toronto, has developed the application of Frequency Domain Photothermal Radiometry (PTR) and Luminescence (LUM) to dental caries detection. Various cases including artificial caries detection have been studied and some of the inherent advantages of the adaptation of this technique to dental diagnostics in conjunction with modulated luminescence as a dual-probe technique have been reported. Based on these studies, a portable, compact diagnostic instrument for dental clinic use has been designed, assembled and tested. A semiconductor laser, optical fibers, a thermoelectric cooled mid-IR detector, and a USB connected data acquisition card were used. Software lock-in amplifier techniques were developed to compute amplitude and phase of PTR and LUM signals. In order to achieve fast measurement and acceptable signal-to-noise ratio (SNR) for clinical application, swept sine waveforms were used. As a result sampling and stabilization time for each measurement point was reduced to a few seconds. A sophisticated software interface was designed to simultaneously record intra-oral camera images with PTR and LUM responses. Preliminary results using this instrument during clinical trials in a dental clinic showed this instrument could detect early caries both from PTR and LUM signals.

  12. A European Quality Control Programme as a cooperative tool between users and a diagnostic company.

    Science.gov (United States)

    Costongs, G M; Janson, P C

    1993-12-01

    Achievement of appropriate precision is a major challenge for the clinical laboratory, particularly in specialized fields such as enzymology and immunochemistry. Especially in immunochemistry, where accuracy can only poorly be checked because of a lack of reference methods and a multitude of detectable epitopes, precision remains an important index of quality. In immunochemical methods there are three main sources of variation: differences in methodology, lot-to-lot variation and performance of the assay, the latter including the skill of the technicians and instrument performance. The results of a European Quality Control Programme for the users of one type of automated immunoassay analyser were compared with a similar Italian Quality Control Programme for users of different immunometric techniques. The precisions (%CV) of the two programmes were compared, as well as the number of values lying within one half of the biological variation of the analysed serum components. Feedback between users and manufacturers leads to a clear improvement in analysis performance, so that most of the considered values come to lie within the acceptable limits of 1/2 of the biological variation. It is concluded that both national and international quality control programmes are very useful for indicating the intrinsic quality of the quantities used in the clinical laboratory.

  13. Italian programme to optimise X-ray diagnostic exposure

    International Nuclear Information System (INIS)

    Susanna, A.; Fioratti, M.P.

    1985-01-01

    Scientific associations in Italy such as the Assoziazione Italiana di Radioprotezione (AIRP), the Societa Italiana di Biologia e Medicina Nucleare (SIBMN) and the Assoziazione Italiana di Radiologia Medica e Medicina Nucleare (SIRMN) have been working on the problem of patient radiation protection for many years; their latest activities are described. Principal features and aims of the NEXT programme and the programme ''Dose and quality image in mammography'' will follow. Local administrations and Health Physics Services are involved in programmes on Genetically Significant Dose (GSD) evaluation or quality assurance: examples of these programmes are shown. Lastly, problems related to the education of radiological operators and radiologists are dealt with. (author)

  14. Dissolvable fluidic time delays for programming multi-step assays in instrument-free paper diagnostics.

    Science.gov (United States)

    Lutz, Barry; Liang, Tinny; Fu, Elain; Ramachandran, Sujatha; Kauffman, Peter; Yager, Paul

    2013-07-21

    Lateral flow tests (LFTs) are an ingenious format for rapid and easy-to-use diagnostics, but they are fundamentally limited to assay chemistries that can be reduced to a single chemical step. In contrast, most laboratory diagnostic assays rely on multiple timed steps carried out by a human or a machine. Here, we use dissolvable sugar applied to paper to create programmable flow delays and present a paper network topology that uses these time delays to program automated multi-step fluidic protocols. Solutions of sucrose at different concentrations (10-70% of saturation) were added to paper strips and dried to create fluidic time delays spanning minutes to nearly an hour. A simple folding card format employing sugar delays was shown to automate a four-step fluidic process initiated by a single user activation step (folding the card); this device was used to perform a signal-amplified sandwich immunoassay for a diagnostic biomarker for malaria. The cards are capable of automating multi-step assay protocols normally used in laboratories, but in a rapid, low-cost, and easy-to-use format.

  15. 78 FR 21128 - Molecular Diagnostic Instruments With Combined Functions; Draft Guidance for Industry and Food...

    Science.gov (United States)

    2013-04-09

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES Food and Drug Administration [Docket No. FDA-2013-D-0258] Molecular Diagnostic Instruments With Combined Functions; Draft Guidance for Industry and Food and Drug Administration Staff; Availability AGENCY: Food and Drug Administration, HHS. ACTION: Notice. SUMMARY: The Food...

  16. Safety critical FPGA-based NPP instrumentation and control systems: assessment, development and implementation

    International Nuclear Information System (INIS)

    Bakhmach, E. S.; Siora, A. A.; Tokarev, V. I.; Kharchenko, V. S.; Sklyar, V. V.; Andrashov, A. A.

    2010-10-01

    The stages of development, production, verification, licensing and implementation methods and technologies of safety critical instrumentation and control systems for nuclear power plants (NPP) based on FPGA (Field Programmable Gates Arrays) technologies are described. A life cycle model and multi-version technologies of dependability and safety assurance of FPGA-based instrumentation and control systems are discussed. An analysis of NPP instrumentation and control systems construction principles developed by Research and Production Corporation Radiy using FPGA-technologies and results of these systems implementation and operation at Ukrainian and Bulgarian NPP are presented. The RADIY TM platform has been designed and developed by Research and Production Corporation Radiy, Ukraine. The main peculiarity of the RADIY TM platform is the use of FPGA as programmable components for logic control operation. The FPGA-based RADIY TM platform used for NPP instrumentation and control systems development ensures sca lability of system functions types, volume and peculiarities (by changing quantity and quality of sensors, actuators, input/output signals and control algorithms); sca lability of dependability (safety integrity) (by changing a number of redundant channel, tiers, diagnostic and reconfiguration procedures); sca lability of diversity (by changing types, depth and method of diversity selection). (Author)

  17. Differences in diagnostic activity in general practice and findings for individuals invited to the danish screening programme for colorectal cancer: a population-based cohort study.

    Science.gov (United States)

    Juul, Jakob Søgaard; Andersen, Berit; Laurberg, Søren; Carlsen, Anders Helles; Olesen, Frede; Vedsted, Peter

    2018-06-22

    To investigate the diagnostic activity in general practice and the cumulative incidence of colorectal cancer (CRC) in individuals invited to the Danish national screening programme for CRC. A historical population-based cohort study. The Danish CRC screening programme and general practice. The 376,198 individuals invited to the Danish CRC screening programme from 1 March to 31 December 2014. The diagnostic activity (consultations and haemoglobin measures) in general practice in the year preceding the screening invitation and the cumulated incidence of CRC in the year following the screening invitation. Screening participants had significantly higher diagnostic activity than non-participants. Individuals with a positive faecal immunochemical test (FIT) had higher diagnostic activity compared to individuals with a negative FIT, and a small increase in the months leading up to the invitation. Individuals with a screen-detected CRC had lower diagnostic activity than individuals with no CRC. In total, 308 (25.3%) of CRCs diagnosed in the invited population were diagnosed outside the screening programme. Non-participants with CRC more often had low socio-economic status, high comorbidity and stage IV CRC than participants with CRC. There was a tendency that participants and those with a positive FIT had a higher diagnostic activity the year before the screening. This was not seen for those with CRC detected through screening. CRC must still be diagnosed in general practice in the invited population and non-participants are of special interest as they have higher risk of late stage CRC. Key Points Current awareness:Individuals with colorectal cancer (CRC) in screening may be symptomatic and CRC may still occur outside screening in the invited population. Most important points:The majority of individuals with CRC in screening cannot be expected to be diagnosed on symptomatic presentation in general practice GPs have to be aware that CRC still occurs outside screening in

  18. Smart Cup: A Minimally-Instrumented, Smartphone-Based Point-of-Care Molecular Diagnostic Device.

    Science.gov (United States)

    Liao, Shih-Chuan; Peng, Jing; Mauk, Michael G; Awasthi, Sita; Song, Jinzhao; Friedman, Harvey; Bau, Haim H; Liu, Changchun

    2016-06-28

    Nucleic acid amplification-based diagnostics offer rapid, sensitive, and specific means for detecting and monitoring the progression of infectious diseases. However, this method typically requires extensive sample preparation, expensive instruments, and trained personnel. All of which hinder its use in resource-limited settings, where many infectious diseases are endemic. Here, we report on a simple, inexpensive, minimally-instrumented, smart cup platform for rapid, quantitative molecular diagnostics of pathogens at the point of care. Our smart cup takes advantage of water-triggered, exothermic chemical reaction to supply heat for the nucleic acid-based, isothermal amplification. The amplification temperature is regulated with a phase-change material (PCM). The PCM maintains the amplification reactor at a constant temperature, typically, 60-65°C, when ambient temperatures range from 12 to 35°C. To eliminate the need for an optical detector and minimize cost, we use the smartphone's flashlight to excite the fluorescent dye and the phone camera to record real-time fluorescence emission during the amplification process. The smartphone can concurrently monitor multiple amplification reactors and analyze the recorded data. Our smart cup's utility was demonstrated by amplifying and quantifying herpes simplex virus type 2 (HSV-2) with LAMP assay in our custom-made microfluidic diagnostic chip. We have consistently detected as few as 100 copies of HSV-2 viral DNA per sample. Our system does not require any lab facilities and is suitable for use at home, in the field, and in the clinic, as well as in resource-poor settings, where access to sophisticated laboratories is impractical, unaffordable, or nonexistent.

  19. Mobile CARS instrument for combustion and plasma diagnostics

    International Nuclear Information System (INIS)

    Anderson, T.J.; Eckbreth, A.C.

    1985-01-01

    A mobile CARS system for combustion and plasma diagnostics is described. The instrument is compact, easily transportable, readily adaptable to a wide variety of laboratories and experiments, capable of withstanding high noise and vibration levels, and remotely operable to protect the operator and delicate components from high noise or hazardous environments. The system is intended for single-pulse temperature and concentration measurements in practical combustion systems, such as gas turbines and diesel engines and plasma process applications. The instrument consists of three major subsystems, each of which is easily transportable. The transmitter consists of a modified, commercially available, 20 Hz Nd:YAG laser, self-constructed dye lasers, and appropriate optics to produce the CARS pump and Stokes beams in the properly phase-matched orientation and direct them to the measured point. The transmitter consists of two optical pallets on a 2 1/2- x 5-ft cart and is connected by a single umbilical to the laser power supply. The receiver subsystem is a smaller optical pallet (2 x 2 ft), which collects the Stokes, pump, and CARS beams, separates them, and focuses the CARS beam into an optical fiber for transmission to a remotely located spectrograph. The receiver also contains two photomultiplier tubes, one to monitor alignment of the transmitter and the other, used in conjunction with a reference cell and the residual Stokes and pump beams, to determine gas concentrations

  20. Instrumentation

    International Nuclear Information System (INIS)

    Prieur, G.; Nadi, M.; Hedjiedj, A.; Weber, S.

    1995-01-01

    This second chapter on instrumentation gives little general consideration on history and classification of instrumentation, and two specific states of the art. The first one concerns NMR (block diagram of instrumentation chain with details on the magnets, gradients, probes, reception unit). The first one concerns precision instrumentation (optical fiber gyro-meter and scanning electron microscope), and its data processing tools (programmability, VXI standard and its history). The chapter ends with future trends on smart sensors and Field Emission Displays. (D.L.). Refs., figs

  1. Evaluation of a web-based ECG-interpretation programme for undergraduate medical students.

    Science.gov (United States)

    Nilsson, Mikael; Bolinder, Gunilla; Held, Claes; Johansson, Bo-Lennart; Fors, Uno; Ostergren, Jan

    2008-04-23

    Most clinicians and teachers agree that knowledge about ECG is of importance in the medical curriculum. Students at Karolinska Institute have asked for more training in ECG-interpretation during their undergraduate studies. Clinical tutors, however, have difficulties in meeting these demands due to shortage of time. Thus, alternative ways to learn and practice ECG-interpretation are needed. Education offered via the Internet is readily available, geographically independent and flexible. Furthermore, the quality of education may increase and become more effective through a superior educational approach, improved visualization and interactivity. A Web-based comprehensive ECG-interpretation programme has been evaluated. Medical students from the sixth semester were given an optional opportunity to access the programme from the start of their course. Usage logs and an initial evaluation survey were obtained from each student. A diagnostic test was performed in order to assess the effect on skills in ECG interpretation. Students from the corresponding course, at another teaching hospital and without access to the ECG-programme but with conventional teaching of ECG served as a control group. 20 of the 32 students in the intervention group had tested the programme after 2 months. On a five-graded scale (1- bad to 5 - very good) they ranked the utility of a web-based programme for this purpose as 4.1 and the quality of the programme software as 3.9. At the diagnostic test (maximal points 16) by the end of the 5-month course at the 6th semester the mean result for the students in the intervention group was 9.7 compared with 8.1 for the control group (p = 0.03). Students ranked the Web-based ECG-interpretation programme as a useful instrument to learn ECG. Furthermore, Internet-delivered education may be more effective than traditional teaching methods due to greater immediacy, improved visualisation and interactivity.

  2. A flexible mobile-device biosensing instrumentation platform for point-of-care medical diagnostics applications

    DEFF Research Database (Denmark)

    Patou, François; Pfreundt, Andrea; Zulfiqar, Azeem

    2014-01-01

    helping to address this challenge. Specifically, Lab-on-Chip (LoC) devices have a key role to play in the advent of Point-of-Care (PoC) medical applications, driving a shift of the medical diagnostics paradigm and the transition from a centralized, technical, high-throughput biological sample analysis...... programmable electrical readout from LoCs potentially comprehending varied transducers addressing different targeted biological markers. A smart-phone/tablet docking-station embeds the hardware interface necessary for the implementation of a smart-phone digital lock-in amplifier. The platform is tested...

  3. Diagnostic accuracy of portable instrumental devices to measure sleep bruxism: a systematic literature review of polysomnographic studies.

    Science.gov (United States)

    Manfredini, D; Ahlberg, J; Castroflorio, T; Poggio, C E; Guarda-Nardini, L; Lobbezoo, F

    2014-11-01

    This study systematically reviews the sleep bruxism (SB) literature published in the MEDLINE and Scopus databases to answer the following question: What is the validity of the different portable instrumental devices that have been proposed to measure SB if compared with polysomnographic (PSG) recordings assumed as the gold standard? Four clinical studies on humans, assessing the diagnostic accuracy of portable instrumental approaches (i.e. Bitestrip, electromyography (EMG)-telemetry recordings and Bruxoff) with respect to PSG, were included in the review. Methodological shortcomings were identified by QUADAS-2 quality assessment. Findings showed contrasting results and supported only in part the validity of the described diagnostic devices with respect to PSG. The positive predictive value (PPV) of the Bitestrip device was 59-100%, with a sensitivity of 71-84·2%, whilst EMG-telemetry recordings had an unacceptable rate of false-positive findings (76·9%), counterbalanced by an almost perfect sensitivity (98·8%). The Bruxoff device had the highest accuracy values, showing an excellent agreement with PSG for both manual (area under ROC = 0·98) and automatic scoring (0·96) options as well as for the simultaneous recording of events with respect to PSG (0·89-0·91). It can be concluded that the available information on the validity of portable instrumental diagnostic approaches with respect to PSG recordings is still scarce and not solid enough to support any non-PSG technique's employ as a stand-alone diagnostic method in the research setting, with the possible exception of the Bruxoff device that needs to be further confirmed with future investigations. © 2014 John Wiley & Sons Ltd.

  4. Summary Report on Synchronization, Diagnostics and Instrumentation

    International Nuclear Information System (INIS)

    Arne Freyberger

    2005-01-01

    The proceedings of Working Group 4 of the 2005 Energy Recovery Linac (ERL) workshop are summarized. Working Group 4 dealt with the challenging topic of beam diagnostics for ERL machines. Energy Recovery Linacs represent a challenge for beam diagnostics from several perspectives; invasive versus non-invasive diagnostics, longitudinal and transverse beam diagnostics, overall machine timing/synchronization and machine protection. Beam diagnostics for an ERL can benefit strongly from the experience at third generation light sources, recirculating linacs and presently operating ERLs. During the workshop there were presentations from all these communities, representing a large range operation experience in beam diagnostics. A brief summary Working Group 4 discussion is presented in this paper

  5. The bone diagnostic instrument III: Testing mouse femora

    Science.gov (United States)

    Randall, Connor; Mathews, Phillip; Yurtsev, Eugene; Sahar, Nadder; Kohn, David; Hansma, Paul

    2009-06-01

    Here we describe modifications that allow the bone diagnostic instrument (BDI) [P. Hansma et al., Rev. Sci. Instrum. 79, 064303 (2008); Rev. Sci. Instrum. 77, 075105 (2006)], developed to test human bone, to test the femora of mice. These modifications include reducing the effective weight of the instrument on the bone, designing and fabricating new probe assemblies to minimize damage to the small bone, developing new testing protocols that involve smaller testing forces, and fabricating a jig for securing the smaller bones for testing. With these modifications, the BDI was used to test the hypothesis that short-term running has greater benefit on the mechanical properties of the femur for young growing mice compared to older, skeletally mature mice. We measured elastic modulus, hardness, and indentation distance increase (IDI), which had previously been shown to be the best discriminators in model systems known to exhibit differences in mechanical properties at the whole bone level. In the young exercised murine femora, the IDI was significantly lower than in young control femora. Since IDI has a relation to postyield properties, these results suggest that exercise during bone development increases post yield mechanical competence. We were also able to measure effects of aging on bone properties with the BDI. There was a significant increase in the IDI, and a significant decrease in the elastic modulus and hardness between the young and old groups. Thus, with the modifications described here, the BDI can take measurements on mouse bones and obtain statistically significant results.

  6. Safety critical FPGA-based NPP instrumentation and control systems: assessment, development and implementation

    Energy Technology Data Exchange (ETDEWEB)

    Bakhmach, E. S.; Siora, A. A.; Tokarev, V. I. [Research and Production Corporation Radiy, 29 Geroev Stalingrada Str., Kirovograd 25006 (Ukraine); Kharchenko, V. S.; Sklyar, V. V.; Andrashov, A. A., E-mail: marketing@radiy.co [Center for Safety Infrastructure-Oriented Research and Analysis, 37 Astronomicheskaya Str., Kharkiv 61085 (Ukraine)

    2010-10-15

    The stages of development, production, verification, licensing and implementation methods and technologies of safety critical instrumentation and control systems for nuclear power plants (NPP) based on FPGA (Field Programmable Gates Arrays) technologies are described. A life cycle model and multi-version technologies of dependability and safety assurance of FPGA-based instrumentation and control systems are discussed. An analysis of NPP instrumentation and control systems construction principles developed by Research and Production Corporation Radiy using FPGA-technologies and results of these systems implementation and operation at Ukrainian and Bulgarian NPP are presented. The RADIY{sup TM} platform has been designed and developed by Research and Production Corporation Radiy, Ukraine. The main peculiarity of the RADIY{sup TM} platform is the use of FPGA as programmable components for logic control operation. The FPGA-based RADIY{sup TM} platform used for NPP instrumentation and control systems development ensures sca lability of system functions types, volume and peculiarities (by changing quantity and quality of sensors, actuators, input/output signals and control algorithms); sca lability of dependability (safety integrity) (by changing a number of redundant channel, tiers, diagnostic and reconfiguration procedures); sca lability of diversity (by changing types, depth and method of diversity selection). (Author)

  7. A simple, inexpensive device for nucleic acid amplification without electricity-toward instrument-free molecular diagnostics in low-resource settings.

    Directory of Open Access Journals (Sweden)

    Paul LaBarre

    2011-05-01

    Full Text Available Molecular assays targeted to nucleic acid (NA markers are becoming increasingly important to medical diagnostics. However, these are typically confined to wealthy, developed countries; or, to the national reference laboratories of developing-world countries. There are many infectious diseases that are endemic in low-resource settings (LRS where the lack of simple, instrument-free, NA diagnostic tests is a critical barrier to timely treatment. One of the primary barriers to the practicality and availability of NA assays in LRS has been the complexity and power requirements of polymerase chain reaction (PCR instrumentation (another is sample preparation.In this article, we investigate the hypothesis that an electricity-free heater based on exothermic chemical reactions and engineered phase change materials can successfully incubate isothermal NA amplification assays. We assess the heater's equivalence to commercially available PCR instruments through the characterization of the temperature profiles produced, and a minimal method comparison. Versions of the prototype for several different isothermal techniques are presented.We demonstrate that an electricity-free heater based on exothermic chemical reactions and engineered phase change materials can successfully incubate isothermal NA amplification assays, and that the results of those assays are not significantly different from ones incubated in parallel in commercially available PCR instruments. These results clearly suggest the potential of the non-instrumented nucleic acid amplification (NINA heater for molecular diagnostics in LRS. When combined with other innovations in development that eliminate power requirements for sample preparation, cold reagent storage, and readout, the NINA heater will comprise part of a kit that should enable electricity-free NA testing for many important analytes.

  8. The DUNDRUM Quartet: validation of structured professional judgement instruments DUNDRUM-3 assessment of programme completion and DUNDRUM-4 assessment of recovery in forensic mental health services

    Directory of Open Access Journals (Sweden)

    McDonnell Kim

    2011-07-01

    Full Text Available Abstract Background Moving a forensic mental health patient from one level of therapeutic security to a lower level or to the community is influenced by more than risk assessment and risk management. We set out to construct and validate structured professional judgement instruments for consistency and transparency in decision making Methods Two instruments were developed, the seven-item DUNDRUM-3 programme completion instrument and the six item DUNDRUM-4 recovery instrument. These were assessed for all 95 forensic patients at Ireland's only forensic mental health hospital. Results The two instruments had good internal consistency (Cronbach's alpha 0.911 and 0.887. Scores distinguished those allowed no leave or accompanied leave from those with unaccompanied leave (ANOVA F = 38.1 and 50.3 respectively, p Conclusions The DUNDRUM-3 programme completion items distinguished significantly between levels of therapeutic security while the DUNDRUM-4 recovery items consistently distinguished those given unaccompanied leave outside the hospital and those in the lowest levels of therapeutic security. This data forms the basis for a prospective study of outcomes now underway.

  9. Instrumentation

    International Nuclear Information System (INIS)

    Decreton, M.

    2000-01-01

    SCK-CEN's research and development programme on instrumentation aims at evaluating the potentials of new instrumentation technologies under the severe constraints of a nuclear application. It focuses on the tolerance of sensors to high radiation doses, including optical fibre sensors, and on the related intelligent data processing needed to cope with the nuclear constraints. Main achievements in these domains in 1999 are summarised

  10. Instrumentation

    Energy Technology Data Exchange (ETDEWEB)

    Decreton, M

    2000-07-01

    SCK-CEN's research and development programme on instrumentation aims at evaluating the potentials of new instrumentation technologies under the severe constraints of a nuclear application. It focuses on the tolerance of sensors to high radiation doses, including optical fibre sensors, and on the related intelligent data processing needed to cope with the nuclear constraints. Main achievements in these domains in 1999 are summarised.

  11. Radiation doses in diagnostic radiology and methods for dose reduction. Report of a co-ordinated research programme (1991-1993)

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1995-04-01

    It is well recognized that diagnostic radiology is the largest contributor to the collective dose from all man-made sources of radiation. Large differences in radiation doses from the same procedures among different X ray rooms have led to the conclusion that there is a potential for dose reduction. A Co-ordinated Research Programme on Radiation Doses in Diagnostic Radiology and Methods for Dose Reduction, involving Member States with different degrees of development, was launched by the IAEA in co-operation with the CEC. This report summarizes the results of the second and final Research Co-ordination Meeting held in Vienna from 4 to 8 October 1993. 22 refs, 6 figs and tabs.

  12. Radiation doses in diagnostic radiology and methods for dose reduction. Report of a co-ordinated research programme (1991-1993)

    International Nuclear Information System (INIS)

    1995-04-01

    It is well recognized that diagnostic radiology is the largest contributor to the collective dose from all man-made sources of radiation. Large differences in radiation doses from the same procedures among different X ray rooms have led to the conclusion that there is a potential for dose reduction. A Co-ordinated Research Programme on Radiation Doses in Diagnostic Radiology and Methods for Dose Reduction, involving Member States with different degrees of development, was launched by the IAEA in co-operation with the CEC. This report summarizes the results of the second and final Research Co-ordination Meeting held in Vienna from 4 to 8 October 1993. 22 refs, 6 figs and tabs

  13. Evaluation of a web-based ECG-interpretation programme for undergraduate medical students

    Directory of Open Access Journals (Sweden)

    Johansson Bo-Lennart

    2008-04-01

    Full Text Available Abstract Background Most clinicians and teachers agree that knowledge about ECG is of importance in the medical curriculum. Students at Karolinska Institutet have asked for more training in ECG-interpretation during their undergraduate studies. Clinical tutors, however, have difficulties in meeting these demands due to shortage of time. Thus, alternative ways to learn and practice ECG-interpretation are needed. Education offered via the Internet is readily available, geographically independent and flexible. Furthermore, the quality of education may increase and become more effective through a superior educational approach, improved visualization and interactivity. Methods A Web-based comprehensive ECG-interpretation programme has been evaluated. Medical students from the sixth semester were given an optional opportunity to access the programme from the start of their course. Usage logs and an initial evaluation survey were obtained from each student. A diagnostic test was performed in order to assess the effect on skills in ECG interpretation. Students from the corresponding course, at another teaching hospital and without access to the ECG-programme but with conventional teaching of ECG served as a control group. Results 20 of the 32 students in the intervention group had tested the programme after 2 months. On a five-graded scale (1- bad to 5 – very good they ranked the utility of a web-based programme for this purpose as 4.1 and the quality of the programme software as 3.9. At the diagnostic test (maximal points 16 by the end of the 5-month course at the 6th semester the mean result for the students in the intervention group was 9.7 compared with 8.1 for the control group (p = 0.03. Conclusion Students ranked the Web-based ECG-interpretation programme as a useful instrument to learn ECG. Furthermore, Internet-delivered education may be more effective than traditional teaching methods due to greater immediacy, improved visualisation and

  14. IAEA programme on maintenance of nuclear instruments

    International Nuclear Information System (INIS)

    Vuister, P.H.

    1986-01-01

    The Medical Applications Section in the Division of Life Sciences of the International Atomic Energy Agency has been engaged since 1975 in activities aimed at the more effective use of nuclear instruments. Activities and achievements are described concerning the conditioning of laboratories, preventive maintenance and repair of instruments, the management thereof, space parts and the promotion of local training in these subjects. (author)

  15. Towards subsidized malaria rapid diagnostic tests. Lessons learned from programmes to subsidise artemisinin-based combination therapies in the private sector: a review.

    Science.gov (United States)

    Lussiana, Cristina

    2016-09-01

    The idea of a private sector subsidy programme of artemisinin-based combination therapies (ACTs) was first proposed in 2004. Since then, several countries around the world have hosted pilot projects or programmes on subsidized ACTs and/or the Affordable Medicines Facility-malaria programme (AMFm). Overall the private sector subsidy programmes of ACTs have been effective in increasing availability of ACTs in the private sector and driving down average prices but struggled to crowd out antimalarial monotherapies. The results obtained from this ambitious strategy should inform policy makers in the designing of future interventions aimed to control malaria morbidity and mortality. Among the interventions recently proposed, a subsidy of rapid diagnostic tests (RDTs) in the private sector has been recommended by governments and international donors to cope with over-treatment with ACTs and to delay the emergence of resistance to artemisinin. In order to improve the cost-effectiveness of co-paid RDTs, we should build on the lessons we learned from almost 10 years of private sector subsidy programmes of ACTs in malaria-endemic countries. © The Author 2015. Published by Oxford University Press in association with The London School of Hygiene and Tropical Medicine.

  16. Quality assurance programme for isotope diagnostic laboratories

    International Nuclear Information System (INIS)

    Krasznai, Istvan

    1987-01-01

    Quality assurance systems are suggested to be introduced in laboratories, in accordance with the recommendations of IAEA and WHO, taking local circumstances into consideration. It is emphasized that a quantitative enhancement of work must not endanger its quality; diagnostic information must be undistorted, reproducible, and gathered with the minimum of radiation burden. National authorities are requested to strengthen their supervision. Recommendations for quality assurance methods are given for medical isotope diagnostic laboratories. (author)

  17. Application of Field Programmable Gate Arrays in Instrumentation and Control Systems of Nuclear Power Plants

    International Nuclear Information System (INIS)

    2016-01-01

    Field programmable gate arrays (FPGAs) are gaining increased attention worldwide for application in nuclear power plant (NPP) instrumentation and control (I&C) systems, particularly for safety and safety related applications, but also for non-safety ones. NPP operators and equipment suppliers see potential advantages of FPGA based digital I&C systems as compared to microprocessor based applications. This is because FPGA based systems can be made simpler, more testable and less reliant on complex software (e.g. operating systems), and are easier to qualify for safety and safety related applications. This publication results from IAEA consultancy meetings covering the various aspects, including design, qualification, implementation, licensing, and operation, of FPGA based I&C systems in NPPs

  18. The beam diagnostic instruments in Beijing radioactive ion-beam facilities isotope separator on-line

    International Nuclear Information System (INIS)

    Ma, Y.; Cui, B.; Ma, R.; Tang, B.; Chen, L.; Huang, Q.; Jiang, W.

    2014-01-01

    The beam diagnostic instruments for Beijing Radioactive Ion-beam Facilities Isotope Separator On-Line are introduced [B. Q. Cui, Z. H. Peng, Y. J. Ma, R. G. Ma, B. Tang, T. Zhang, and W. S. Jiang, Nucl. Instrum. Methods 266, 4113 (2008); T. J. Zhang, X. L. Guan, and B. Q. Cui, in Proceedings of APAC 2004, Gyeongju, Korea, 2004, http://www.jacow.org , p. 267]. For low intensity ion beam [30–300 keV/1 pA–10 μA], the beam profile monitor, the emittance measurement unit, and the analyzing slit will be installed. For the primary proton beam [100 MeV/200 μA], the beam profile scanner will be installed. For identification of the nuclide, a beam identification unit will be installed. The details of prototype of the beam diagnostic units and some experiment results will be described in this article

  19. Instrumentation for localized superconducting cavity diagnostics

    Energy Technology Data Exchange (ETDEWEB)

    Conway, Z. A. [Argonne National Lab. (ANL), Argonne, IL (United States). Physics Division; Ge, M. [Cornell Lab. for Accelerator-Based Sciences and Education, Ithaca, NY (United States); Iwashita, Y. [Kyoto Univ. (Japan)

    2017-01-12

    Superconducting accelerator cavities are now routinely operated at levels approaching the theoretical limit of niobium. To achieve these operating levels more information than is available from the RF excitation signal is required to characterize and determine fixes for the sources of performance limitations. This information is obtained using diagnostic techniques which complement the analysis of the RF signal. In this paper we describe the operation and select results from three of these diagnostic techniques: the use of large scale thermometer arrays, second sound wave defect location and high precision cavity imaging with the Kyoto camera.

  20. Principals, agents and research programmes

    OpenAIRE

    Elizabeth Shove

    2003-01-01

    Research programmes appear to represent one of the more powerful instruments through which research funders (principals) steer and shape what researchers (agents) do. The fact that agents navigate between different sources and styles of programme funding and that they use programmes to their own ends is readily accommodated within principal-agent theory with the help of concepts such as shirking and defection. Taking a different route, I use three examples of research programming (by the UK, ...

  1. Effect Size (Cohen's d of Cognitive Screening Instruments Examined in Pragmatic Diagnostic Accuracy Studies

    Directory of Open Access Journals (Sweden)

    Andrew J. Larner

    2014-07-01

    Full Text Available Background/Aims: Many cognitive screening instruments (CSI are available to clinicians to assess cognitive function. The optimal method comparing the diagnostic utility of such tests is uncertain. The effect size (Cohen's d, calculated as the difference of the means of two groups divided by the weighted pooled standard deviations of these groups, may permit such comparisons. Methods: Datasets from five pragmatic diagnostic accuracy studies, which examined the Mini-Mental State Examination (MMSE, the Mini-Mental Parkinson (MMP, the Six-Item Cognitive Impairment Test (6CIT, the Montreal Cognitive Assessment (MoCA, the Test Your Memory test (TYM, and the Addenbrooke's Cognitive Examination-Revised (ACE-R, were analysed to calculate the effect size (Cohen's d for the diagnosis of dementia versus no dementia and for the diagnosis of mild cognitive impairment versus no dementia (subjective memory impairment. Results: The effect sizes for dementia versus no dementia diagnosis were large for all six CSI examined (range 1.59-1.87. For the diagnosis of mild cognitive impairment versus no dementia, the effect sizes ranged from medium to large (range 0.48-1.45, with MoCA having the largest effect size. Conclusion: The calculation of the effect size (Cohen's d in diagnostic accuracy studies is straightforward. The routine incorporation of effect size calculations into diagnostic accuracy studies merits consideration in order to facilitate the comparison of the relative value of CSI.

  2. SET-Routes programme

    CERN Multimedia

    Marietta Schupp, EMBL Photolab

    2008-01-01

    Dr Sabine Hentze, specialist in human genetics, giving an Insight Lecture entitled "Human Genetics – Diagnostics, Indications and Ethical Issues" on 23 September 2008 at EMBL Heidelberg. Activities in a achool in Budapest during a visit of Angela Bekesi, Ambassadors for the SET-Routes programme.

  3. Design and installation of advanced computer safety related instrumentation

    International Nuclear Information System (INIS)

    Koch, S.; Andolina, K.; Ruether, J.

    1993-01-01

    The rapidly developing area of computer systems creates new opportunities for commercial utilities operating nuclear reactors to improve plant operation and efficiency. Two of the main obstacles to utilizing the new technology in safety-related applications is the current policy of the licensing agencies and the fear of decision making managers to introduce new technologies. Once these obstacles are overcome, advanced diagnostic systems, CRT-based displays, and advanced communication channels can improve plant operation considerably. The article discusses outstanding issues in the area of designing, qualifying, and licensing of computer-based instrumentation and control systems. The authors describe the experience gained in designing three safety-related systems, that include a Programmable Logic Controller (PLC) based Safeguard Load Sequencer for NSP Prairie Island, a digital Containment Isolation monitoring system for TVA Browns Ferry, and a study that was conducted for EPRI/NSP regarding a PLC-based Reactor Protection system. This article presents the benefits to be gained in replacing existing, outdated equipment with new advanced instrumentation

  4. Establishment of an X radiation equipment quality control programme using non invasive meters

    International Nuclear Information System (INIS)

    Lucena, Rodrigo Ferreira de

    2010-01-01

    The objective of this work was to study the behavior of the mainly X ray equipment calibration laboratory of IPEN, operated in the range from 25 kV to 150 kV using a PTW non invasive meter, model Diavolt TM , and an ORTEC spectrometry system, model NOMAD-PLUS 92X, for the establishment of a quality control programme. The Diavolt meter was used for measurements of air kerma, peak voltage and practical peak voltage. The measurements were made varying parameters such as electrical current, X radiation quality for radiation diagnostic, angulations of the meter and its distance in relation to the focal spot of the X ray tube. The results were compared with data found in the literature. Several spectra were generated with the spectrometer system with the purpose of determine the peak voltage in function of the nominal voltage and to characterize the radiation qualities for radiation diagnostic previously determined. The established quality control programme enables the management of the appropriate functioning of the measurement instruments (ionization chambers, voltage and current meter and spectrometer) as well as of the X radiation system. This work also has proposed a time interval to run each one of the tests. (author)

  5. The use of a four-tier wave diagnostic instrument to measure the scientific literacy among students in SMA Negeri 2 Karanganyar

    Science.gov (United States)

    Krisdiana, A.; Aminah, N. S.; Nurosyid, F.

    2018-03-01

    This study aims to investigate the scientific literacy among 12th grade science students in SMA Negeri 2 Karanganyar. The instrument used is a four-tier wave diagnostic instrument. This instrument was originally used to diagnose students’ conceptions about nature and propagation of waves. This study using quantitative descriptive method. The diagnostic results based on dominant students’ answers show the lack of knowledge percentage of 14.3%-77.1%, alternative conceptions percentage 0%-60%, scientific conceptions percentage 0%-65.7%. Lack of knowledge indicated when there is doubt about at least one tier of the student’s answer. The results of the research shows that the students’ dominant scientific literacy is in the nominal literacy category with the percentage of 22.9% - 91.4%, the functional literacy with the percentage 2.86% - 28.6%, and the conceptual/procedural literacy category with the percentage 0% - 65.7%. Description level of nominal literacy in context of the current study is student have alternative conceptions and lack of knowledge. Student recognize the scientific terms, but is not capable to justify this term.

  6. Measuring diagnostic and predictive accuracy in disease management: an introduction to receiver operating characteristic (ROC) analysis.

    Science.gov (United States)

    Linden, Ariel

    2006-04-01

    Diagnostic or predictive accuracy concerns are common in all phases of a disease management (DM) programme, and ultimately play an influential role in the assessment of programme effectiveness. Areas, such as the identification of diseased patients, predictive modelling of future health status and costs and risk stratification, are just a few of the domains in which assessment of accuracy is beneficial, if not critical. The most commonly used analytical model for this purpose is the standard 2 x 2 table method in which sensitivity and specificity are calculated. However, there are several limitations to this approach, including the reliance on a single defined criterion or cut-off for determining a true-positive result, use of non-standardized measurement instruments and sensitivity to outcome prevalence. This paper introduces the receiver operator characteristic (ROC) analysis as a more appropriate and useful technique for assessing diagnostic and predictive accuracy in DM. Its advantages include; testing accuracy across the entire range of scores and thereby not requiring a predetermined cut-off point, easily examined visual and statistical comparisons across tests or scores, and independence from outcome prevalence. Therefore the implementation of ROC as an evaluation tool should be strongly considered in the various phases of a DM programme.

  7. Target Diagnostic Control System Implementation for the National Ignition Facility

    International Nuclear Information System (INIS)

    Shelton, R.T.; Kamperschroer, J.H.; Lagin, L.J.; Nelson, J.R.; O'Brien, D.W.

    2010-01-01

    The extreme physics of targets shocked by NIF's 192-beam laser are observed by a diverse suite of diagnostics. Many diagnostics are being developed by collaborators at other sites, but ad hoc controls could lead to unreliable and costly operations. A Diagnostic Control System (DCS) framework for both hardware and software facilitates development and eases integration. Each complex diagnostic typically uses an ensemble of electronic instruments attached to sensors, digitizers, cameras, and other devices. In the DCS architecture each instrument is interfaced to a low-cost Windows XP processor and Java application. Each instrument is aggregated with others as needed in the supervisory system to form an integrated diagnostic. The Java framework provides data management, control services and operator GUI generation. DCS instruments are reusable by replication with reconfiguration for specific diagnostics in XML. Advantages include minimal application code, easy testing, and high reliability. Collaborators save costs by assembling diagnostics with existing DCS instruments. This talk discusses target diagnostic instrumentation used on NIF and presents the DCS architecture and framework.

  8. The DUNDRUM Quartet: validation of structured professional judgement instruments DUNDRUM-3 assessment of programme completion and DUNDRUM-4 assessment of recovery in forensic mental health services.

    LENUS (Irish Health Repository)

    O'Dwyer, Sarah

    2011-07-03

    Abstract Background Moving a forensic mental health patient from one level of therapeutic security to a lower level or to the community is influenced by more than risk assessment and risk management. We set out to construct and validate structured professional judgement instruments for consistency and transparency in decision making Methods Two instruments were developed, the seven-item DUNDRUM-3 programme completion instrument and the six item DUNDRUM-4 recovery instrument. These were assessed for all 95 forensic patients at Ireland\\'s only forensic mental health hospital. Results The two instruments had good internal consistency (Cronbach\\'s alpha 0.911 and 0.887). Scores distinguished those allowed no leave or accompanied leave from those with unaccompanied leave (ANOVA F = 38.1 and 50.3 respectively, p < 0.001). Scores also distinguished those in acute\\/high security units from those in medium or in low secure\\/pre-discharge units. Each individual item distinguished these levels of need significantly. The DUNDRUM-3 and DUNDRUM-4 correlated moderately with measures of dynamic risk and with the CANFOR staff rated unmet need (Spearman r = 0.5, p < 0.001). Conclusions The DUNDRUM-3 programme completion items distinguished significantly between levels of therapeutic security while the DUNDRUM-4 recovery items consistently distinguished those given unaccompanied leave outside the hospital and those in the lowest levels of therapeutic security. This data forms the basis for a prospective study of outcomes now underway.

  9. Advances in constant-velocity Moessbauer instrumentation

    International Nuclear Information System (INIS)

    Veiga, A.; Martinez, N.; Zelis, P. Mendoza; Pasquevich, G. A.; Sanchez, F. H.

    2006-01-01

    A prototype of a programmable constant-velocity scaler is presented. This instrument allows the acquisition of partial Moessbauer spectra in selected energy regions using standard drivers and transducers. It can be fully operated by a remote application, thus data acquisition can be automated. The instrument consists of a programmable counter and a constant-velocity reference. The reference waveform generator is amplitude modulated with 13-bit resolution, and is programmable in a wide range of frequencies and waveforms in order to optimize the performance of the transducer. The counter is compatible with most standard SCA, and is configured as a rate-meter that provides counts per selectable time slice at the programmed velocity. As a demonstration of the instrument applications, a partial Moessbauer spectrum of a natural iron foil was taken. Only positive energies were studied in 512 channels, accumulating 20 s per channel. A line width of 0.20 mm/s was achieved, performing with an efficiency of 80%.

  10. MFTF plasma diagnostics data acquisition system

    International Nuclear Information System (INIS)

    Davis, G.E.; Coffield, F.E.

    1979-01-01

    The initial goal of the Data Acquisition System (DAS) is to control 11 instruments chosen as the startup diagnostic set and to collect, process, and display the data that these instruments produce. These instruments are described in a paper by Stan Thomas, et. al. entitled ''MFTF Plasma Diagnostics System.'' The DAS must be modular and flexible enough to allow upgrades in the quantity of data taken by an instrument, and also to allow new instruments to be added to the system. This is particularly necessary to support a research project where needs and requirements may change rapidly as a result of experimental findings. Typically, the startup configuration of the diagnostic instruments will contain only a fraction of the planned detectors, and produce approximately one half the data that the expanded version is designed to generate. Expansion of the system will occur in fiscal year 1982

  11. FMIT diagnostic instrumentation

    International Nuclear Information System (INIS)

    Gilpatrick, J.D.; Chamberlin, D.D.

    1985-01-01

    The Fusion Materials Irradiation Test facility (FMIT) cw prototype accelerator has noninterceptive beamline instrumentation to measure beam parameters. The transverse emittances and beam profiles are measured with an array of photodiode sensors viewing light emitted from the beam region. Tomographic reconstructions of both spatial-density distributions and of transverse-emittance distributions are performed throughout a quadrupole focusing section. Beam bunches passing through capacitive probes produce bipolar waveforms whose zero crossing corresponds to the bunch's longitudinal centroid. By measuring the time required for a bunch to travel the known distance between two probes, velocity and energy are determined. A toroidal transformer measures the average ac beam current. Beam spill is measured by a set of movable jaws that intercept the beam edges. Each jaw contains a water flow channel whose flow rate and differential temperature are measured to derive a transverse power distribution. Beam centroid position is measured by a four-lobe, magnetic-loop pickup. 5 refs., 6 figs

  12. 40+ Years of Instrumentation for the La Silla Paranal Observatory

    Science.gov (United States)

    D'Odorico, S.

    2018-03-01

    As ESO Period 100 comes to a close, I look back at the development of ESO's instrumentation programme over more than 40 years. Instrumentation and detector activities were initially started by a small group of designers, engineers, technicians and astronomers while ESO was still at CERN in Geneva in the late 1970s. They have since led to the development of a successful suite of optical and infrared instruments for the La Silla Paranal Observatory, as testified by the continuous growth in the number of proposals for observing time and in the publications based on data from ESO telescopes. The instrumentation programme evolved significantly with the VLT and most instruments were developed by national institutes in close cooperation with ESO. This policy was a cornerstone of the VLT programme from the beginning and a key to its success.

  13. Quality assurance in diagnostic radiology in Hungary - first experiences in acceptance testing

    International Nuclear Information System (INIS)

    Porubszky, T.; Pellet, S.; Ballay, L.; Talian, L.; Giczi, F.

    2003-01-01

    It is a general experience that optimum imaging with minimum patient doses, moreover, the safe operation and long life of X-ray equipment can be assured by regular measurement of technical parameters and checking of their constancy (routine performance testing) only. These tests are generally known as quality control, while together with the so-called corrective actions and its management it is called (physical-technical) quality assurance (QA). In the European Union, Directive 97/43/EURATOM about radiation protection of patients requires - among others - the good practice of (physical-technical) quality assurance. In Hungary, Decree No. 31/2001. (X.3.) of the Minister of Health harmonizes all of its requirements. Acceptance testing of new diagnostic X-ray equipment is assigned to NPHC-NRIRR. QA has been a daily practice in radiation therapy and nuclear medicine for a long time. A National Patient Dose Assessment Programme has also successfully run since 1989. We had, however, only few preliminaries in QA in diagnostic radiology in the second half of the eighties. Nowadays there are running QA programmes in some hospitals and mammography centres. he testing activity of our institute is independent from manufacturers, it is run within the frame of an accredited testing laboratory, using calibrated measuring instruments and based on valid international standards. So the started way of implementing QA in diagnostic radiology needs a lot of further efforts, adapting experiences of other countries, and also some financial help to reach an acceptable level in the EU. (authors)

  14. Towards a Diagnostic Instrument to Identify Improvement Opportunities for Quality Controlled Logistics in Agrifood Supply Chain Networks

    Directory of Open Access Journals (Sweden)

    Jack G.A.J. van der Vorst

    2011-10-01

    Full Text Available  Western-European consumers have become not only more demanding on product availability in retail outlets but also on other food attributes such as quality, integrity, and safety. When (redesigning food supply-chain networks, from a logistics point of view, one has to consider these demands next to traditional efficiency and responsiveness requirements. The concept ‘quality controlled logistics’ (QCL hypothesizes that if product quality in each step of the supply chain can be predicted in advance, goods flows can be controlled in a pro-active manner and better chain designs can be established resulting in higher product availability, constant quality, and less product losses. The paper discusses opportunities of using real-time product quality information for improvement of the design and management of ‘AgriFood Supply Chain Networks’, and presents a preliminary diagnostic instrument for assessment of ‘critical quality’ and ‘logistics control’ points in the supply chain network. Results of a tomato-chain case illustrate the added value of the QCL concept for identifying improvement opportunities in the supply chain as to increase both product availability and quality. Future research aims for the further development of the diagnostic instrument and the quantification of costs and benefits of QCL scenarios.

  15. The Agency programme for the development of safeguards techniques and instrumentation

    International Nuclear Information System (INIS)

    Lopez-Menchero, E.; Waligura, A.J.

    1976-01-01

    The programme of the Division of Development concentrates attention upon a variety of technical problems and tasks to enable the Agency safeguards system to achieve its safeguards objectives most economically for the Agency, the Member States and the nuclear facility operators. The programme must take into account the changes which may occur in the Agency's tasks as a consequence of implementation of safeguards in States with important nuclear activities. This paper attempts to summarize where the Agency methods and techniques development programme stands on meeting defined technical objectives, to point out where the main problems lie and to offer some guidelines for their solution. (author)

  16. Performance assessment of patient dosimetry services and X-ray quality assurance instruments used in diagnostic radiology

    International Nuclear Information System (INIS)

    Green, S.; Palethrope, J.E.; Peach, D.; Bradley, D.A.

    1999-01-01

    Experiences of the Regional Radiation Physics and Protection Service (RRPPS) in performance assessment of diagnostic X-ray QA instrumentation and on-patient dosemeters are recounted. Issues relating to the provision of realistic and reproducible reference conditions for calibrated X-irradiations are considered and summary statistics from test measurements of dose and kVp meters are provided. For both dose and kVp meters it is indicated that as many as 25% of instruments used in routine use in the U.K. may require some adjustment before they can truly be said to be performing as the manufacturer intended. Results from intercomparison exercises for patient dosimetry services are also discussed. It is apparent that, for those centres participating in the exercise, dose assessments are generally being obtained to within a bias and a relative standard deviation of less then 10%

  17. On Representative Spaceflight Instrument and Associated Instrument Sensor Web Framework

    Science.gov (United States)

    Kizhner, Semion; Patel, Umeshkumar; Vootukuru, Meg

    2007-01-01

    Sensor Web-based adaptation and sharing of space flight mission resources, including those of the Space-Ground and Control-User communication segment, could greatly benefit from utilization of heritage Internet Protocols and devices applied for Spaceflight (SpaceIP). This had been successfully demonstrated by a few recent spaceflight experiments. However, while terrestrial applications of Internet protocols are well developed and understood (mostly due to billions of dollars in investments by the military and industry), the spaceflight application of Internet protocols is still in its infancy. Progress in the developments of SpaceIP-enabled instrument components will largely determine the SpaceIP utilization of those investments and acceptance in years to come. Likewise SpaceIP, the development of commercial real-time and instrument colocated computational resources, data compression and storage, can be enabled on-board a spacecraft and, in turn, support a powerful application to Sensor Web-based design of a spaceflight instrument. Sensor Web-enabled reconfiguration and adaptation of structures for hardware resources and information systems will commence application of Field Programmable Arrays (FPGA) and other aerospace programmable logic devices for what this technology was intended. These are a few obvious potential benefits of Sensor Web technologies for spaceflight applications. However, they are still waiting to be explored. This is because there is a need for a new approach to spaceflight instrumentation in order to make these mature sensor web technologies applicable for spaceflight. In this paper we present an approach in developing related and enabling spaceflight instrument-level technologies based on the new concept of a representative spaceflight Instrument Sensor Web (ISW).

  18. Report on the Enabling Technology Programme Optomechatronics

    NARCIS (Netherlands)

    Sadeghian Marnani, H.; Nulkes-de Groot, N.

    2014-01-01

    The last four years the research Programme Optomechatronics focused on the development of new key technologies for manufacturing and testing equipment and scientific instrumentation. The challenge is to develop instruments with higher accuracy, less costs and higher throughput than we can achieve

  19. Target diagnostic control system implementation for the National Ignition Facility (invited)

    Energy Technology Data Exchange (ETDEWEB)

    Shelton, R. T.; Kamperschroer, J. H.; Lagin, L. J.; Nelson, J. R.; O' Brien, D. W. [Lawrence Livermore National Laboratory, Livermore, California 94550 (United States)

    2010-10-15

    The extreme physics of targets shocked by NIF's 192-beam laser is observed by a diverse suite of diagnostics. Many diagnostics are being developed by collaborators at other sites, but ad hoc controls could lead to unreliable and costly operations. A diagnostic control system (DCS) framework for both hardware and software facilitates development and eases integration. Each complex diagnostic typically uses an ensemble of electronic instruments attached to sensors, digitizers, cameras, and other devices. In the DCS architecture each instrument is interfaced to a low-cost WINDOWS XP processor and JAVA application. Each instrument is aggregated with others as needed in the supervisory system to form an integrated diagnostic. The JAVA framework provides data management, control services, and operator graphical user interface generation. DCS instruments are reusable by replication with reconfiguration for specific diagnostics in extensible markup language. Advantages include minimal application code, easy testing, and high reliability. Collaborators save costs by assembling diagnostics with existing DCS instruments. This talk discusses target diagnostic instrumentation used on NIF and presents the DCS architecture and framework.

  20. Target diagnostic control system implementation for the National Ignition Facility (invited)

    International Nuclear Information System (INIS)

    Shelton, R. T.; Kamperschroer, J. H.; Lagin, L. J.; Nelson, J. R.; O'Brien, D. W.

    2010-01-01

    The extreme physics of targets shocked by NIF's 192-beam laser is observed by a diverse suite of diagnostics. Many diagnostics are being developed by collaborators at other sites, but ad hoc controls could lead to unreliable and costly operations. A diagnostic control system (DCS) framework for both hardware and software facilitates development and eases integration. Each complex diagnostic typically uses an ensemble of electronic instruments attached to sensors, digitizers, cameras, and other devices. In the DCS architecture each instrument is interfaced to a low-cost WINDOWS XP processor and JAVA application. Each instrument is aggregated with others as needed in the supervisory system to form an integrated diagnostic. The JAVA framework provides data management, control services, and operator graphical user interface generation. DCS instruments are reusable by replication with reconfiguration for specific diagnostics in extensible markup language. Advantages include minimal application code, easy testing, and high reliability. Collaborators save costs by assembling diagnostics with existing DCS instruments. This talk discusses target diagnostic instrumentation used on NIF and presents the DCS architecture and framework.

  1. Digital Signal Processing in Beam Instrumentation Latest Trends and Typical Applications

    CERN Document Server

    Angoletta, Maria Elena

    2003-01-01

    The last decade has seen major improvements in digital hardware, algortithms and software, which have trickled down to the Beam Instrumentation (BI) area. An advantageous transition is taking place towards systems with an ever-stronger digital presence. Digital systems are assembled by means of a rather small number of basic building blocks, with improved speed, precision, signal-to-noise ratio, dynamic range, flexibility, and accompanied by a range of powerful and user-friendly development tools. The paper reviews current digital BI trends, including using Digital Signal Processors, Field Programmable Gate Arrays, Digital Receivers and General Purpose Processors as well as some useful processing algorithms. Selected digital applications are illustrated on control/feedback and beam diagnostics.

  2. Status of TMX upgrade diagnostics construction

    International Nuclear Information System (INIS)

    Hornady, R.S.; Davis, J.C.; Simonen, T.C.

    1981-01-01

    This report describes the status of the initial TMX Upgrade diagnostics and the state of development of additional diagnostics being prepared for later TMX Upgrade experiments. The initial diagnostic instrument set has been described in the TMX Upgrade Proposal. This set is required to get TMX Upgrade operational and to evaluate its initial performance. Additional diagnostic instruments are needed to then carry out the more detailed experiments outlined by the TMX Upgrade program milestones. The relation of these new measurements to the physics program is described in The TMX Upgrade Program Plan

  3. Performing the Super Instrument

    DEFF Research Database (Denmark)

    Kallionpaa, Maria

    2016-01-01

    can empower performers by producing super instrument works that allow the concert instrument to become an ensemble controlled by a single player. The existing instrumental skills of the performer can be multiplied and the qualities of regular acoustic instruments extended or modified. Such a situation......The genre of contemporary classical music has seen significant innovation and research related to new super, hyper, and hybrid instruments, which opens up a vast palette of expressive potential. An increasing number of composers, performers, instrument designers, engineers, and computer programmers...... have become interested in different ways of “supersizing” acoustic instruments in order to open up previously-unheard instrumental sounds. Super instruments vary a great deal but each has a transformative effect on the identity and performance practice of the performing musician. Furthermore, composers...

  4. A clinical audit programme for diagnostic radiology: The Approach adopted by the international atomic energy agency

    International Nuclear Information System (INIS)

    Faulkner, K.; Jaervinen, H.; Butler, P.; McLean, I. D.; Pentecost, M.; Rickard, M.; Abdullah, B.

    2010-01-01

    The International Atomic Energy Agency (IAEA) has a mandate to assist member states in areas of human health and particularly in the use of radiation for diagnosis and treatment. Clinical audit is seen as an essential tool to assist in assuring the quality of radiation medicine, particularly in the instance of multidisciplinary audit of diagnostic radiology. Consequently, an external clinical audit programme has been developed by the IAEA to examine the structure and processes existent at a clinical site, with the basic objectives of: (1) improvement in the quality of patient care; (2) promotion of the effective use of resources; (3) enhancement of the provision and organisation of clinical services; (4) further professional education and training. These objectives apply in four general areas of service delivery, namely quality management and infrastructure, patient procedures, technical procedures and education, training and research. In the IAEA approach, the audit process is initiated by a request from the centre seeking the audit. A three-member team, comprising a radiologist, medical physicist and radiographer, subsequently undertakes a 5-d audit visit to the clinical site to perform the audit and write the formal audit report. Preparation for the audit visit is crucial and involves the local clinical centre completing a form, which provides the audit team with information on the clinical centre. While all main aspects of clinical structure and process are examined, particular attention is paid to radiation-related activities as described in the relevant documents such as the IAEA Basic Safety Standards, the Code of Practice for Dosimetry in Diagnostic Radiology and related equipment and quality assurance documentation. It should be stressed, however, that the clinical audit does not have any regulatory function. The main purpose of the IAEA approach to clinical audit is one of promoting quality improvement and learning. This paper describes the background to

  5. A clinical audit programme for diagnostic radiology: the approach adopted by the International Atomic Energy Agency.

    Science.gov (United States)

    Faulkner, K; Järvinen, H; Butler, P; McLean, I D; Pentecost, M; Rickard, M; Abdullah, B

    2010-01-01

    The International Atomic Energy Agency (IAEA) has a mandate to assist member states in areas of human health and particularly in the use of radiation for diagnosis and treatment. Clinical audit is seen as an essential tool to assist in assuring the quality of radiation medicine, particularly in the instance of multidisciplinary audit of diagnostic radiology. Consequently, an external clinical audit programme has been developed by the IAEA to examine the structure and processes existent at a clinical site, with the basic objectives of: (1) improvement in the quality of patient care; (2) promotion of the effective use of resources; (3) enhancement of the provision and organisation of clinical services; (4) further professional education and training. These objectives apply in four general areas of service delivery, namely quality management and infrastructure, patient procedures, technical procedures and education, training and research. In the IAEA approach, the audit process is initiated by a request from the centre seeking the audit. A three-member team, comprising a radiologist, medical physicist and radiographer, subsequently undertakes a 5-d audit visit to the clinical site to perform the audit and write the formal audit report. Preparation for the audit visit is crucial and involves the local clinical centre completing a form, which provides the audit team with information on the clinical centre. While all main aspects of clinical structure and process are examined, particular attention is paid to radiation-related activities as described in the relevant documents such as the IAEA Basic Safety Standards, the Code of Practice for Dosimetry in Diagnostic Radiology and related equipment and quality assurance documentation. It should be stressed, however, that the clinical audit does not have any regulatory function. The main purpose of the IAEA approach to clinical audit is one of promoting quality improvement and learning. This paper describes the background to

  6. Air-operated valve diagnostics: requirements, programmes and experiences

    International Nuclear Information System (INIS)

    Cervilla, Remedios; Vallana, Fernando; Laporta, Jose Maria

    2014-01-01

    The aim of this paper is to present some elements in the field of air-operated valve (AOV) diagnostics from the perspective of Tecnatom, as a testing services provider in the national and international nuclear park. Throughout the following lines, we summarize the regulatory framework existing in Spain and the current practices in Spanish nuclear power plants regarding the AOV programs, the role of Tecnatom as a service provider and our testing techniques. Finally, a real test case is presented, to illustrate the value of diagnostic as predictive maintenance and early degradation detection tool. (authors)

  7. CIT diagnostic computer interface studies

    International Nuclear Information System (INIS)

    Rauch, W.; Hayes, S.; Lowrance, J.; Oliaro, G.; Sauthoff, N.; Sichta, P.; Stark, W.

    1987-01-01

    This paper presents the on-going work performed in proposing instrumentation equipment and communications networks for the Diagnostic Data Acquisition and Diagnostic Instrumentation and Control System for the Compact Ignition Torus (CIT), which will begin operation in 1993. Consideration is given to the system criteria and requirements and their influence on the appropriate application of instrumentation and communication technologies to the system. This paper concentrates on the investigation of the bus communication technologies as they apply to the CIT data acquisition system. It compares CAMAC, VME, and FASTBUS as standards for data acquisition. The paper describes the connectivity between VAX equipment and CAMAC and VME instrumentation systems. Instrumentation and communication functionality and performance levels are presented as factors important to the overall data acquisition system performance

  8. The Beam Instrumentation and Diagnostic Challenges for LHC Operation at high Energy

    CERN Document Server

    Jones, OR

    2014-01-01

    This contribution will present the role of beam diagnostics in facing the challenges posed by running the LHC close to its design energy of 7TeV. Machine protection will be ever more critical, with the quench level of the magnets significantly reduced, so relying heavily on the beam loss system, abort gap monitor, interlocks on the beam position and fast beam current change system. Non-invasive profile monitoring also becomes more of a challenge, with standard synchrotron light imaging limited by diffraction and rest gas ionization monitoring dominated by space charge effects. There is also a requirement to better understand beam instabilities, of which several were observed during Run I, leading to the need for synchronised bunch-by-bunch, turn-by-turn information from many distributed instrumentation systems. All of these challenges will be discussed along with the strategies adopted to overcome them.

  9. Vibration diagnostics instrumentation for ILC

    Energy Technology Data Exchange (ETDEWEB)

    Bertolini, A.

    2007-06-15

    The future e{sup -}e{sup +} 500 GeV International Linear Collider will rely on unprecedented nanometer scale particle beam size at the interaction point, in order to achieve the design luminosity. Tight tolerances on static and dynamic alignment of the accelerator cavities and optical components are demanded to transport and focus the high energy electron and positron beams with reasonable position jitter and low emittance. A brief review of techniques and devices evaluated and developed so far for the vibration diagnostics of the machine is presented in this paper. (orig.)

  10. Vibration diagnostics instrumentation for ILC

    International Nuclear Information System (INIS)

    Bertolini, A.

    2007-06-01

    The future e - e + 500 GeV International Linear Collider will rely on unprecedented nanometer scale particle beam size at the interaction point, in order to achieve the design luminosity. Tight tolerances on static and dynamic alignment of the accelerator cavities and optical components are demanded to transport and focus the high energy electron and positron beams with reasonable position jitter and low emittance. A brief review of techniques and devices evaluated and developed so far for the vibration diagnostics of the machine is presented in this paper. (orig.)

  11. PORT (Programme of Recognition and Therapy): the first Polish recognition and treatment programme for patients with an at-risk mental state.

    Science.gov (United States)

    Kotlicka-Antczak, Magdalena; Pawełczyk, Tomasz; Rabe-Jabłońska, Jolanta; Pawełczyk, Agnieszka

    2015-08-01

    To present the activities of the first early intervention centre in Poland and the Programme of Recognition and Therapy (PORT) run by the centre. An overview of the admission process, diagnostic procedures and therapeutic interventions offered to individuals with an at-risk mental state. The PORT programme, developed in 2010, included 81 individuals, aged 15-29 years so far. The diagnostic procedures consists of evaluation of symptoms with the use of the Comprehensive Assessment of At-Risk Mental State (CAARMS), assessment of premorbid and current personality traits and the evaluation of cognitive functions. Therapeutic interventions include cognitive behavioural therapy, diet supplementation with omega-3 fatty acids and pharmacological treatment. Overall rate of conversion into psychosis within the years 2010-2103 was 18.5%. The programme has also been a source of research in the field of early psychosis. The PORT programme enables young people with an ARMS an easy access to the specialized service offering treatment tailored to their specific needs. © 2014 Wiley Publishing Asia Pty Ltd.

  12. Development of intelligent control system for X-ray streak camera in diagnostic instrument manipulator

    International Nuclear Information System (INIS)

    Pei, Chengquan; Wu, Shengli; Tian, Jinshou; Liu, Zhen; Fang, Yuman; Gao, Guilong; Liang, Lingliang; Wen, Wenlong

    2015-01-01

    An intelligent control system for an X ray streak camera in a diagnostic instrument manipulator (DIM) is proposed and implemented, which can control time delay, electric focusing, image gain adjustment, switch of sweep voltage, acquiring environment parameters etc. The system consists of 16 A/D converters and 16 D/A converters, a 32-channel general purpose input/output (GPIO) and two sensors. An isolated DC/DC converter with multi-outputs and a single mode fiber were adopted to reduce the interference generated by the common ground among the A/D, D/A and I/O. The software was designed using graphical programming language and can remotely access the corresponding instrument from a website. The entire intelligent control system can acquire the desirable data at a speed of 30 Mb/s and store it for later analysis. The intelligent system was implemented on a streak camera in a DIM and it shows a temporal resolution of 11.25 ps, spatial distortion of less than 10% and dynamic range of 279:1. The intelligent control system has been successfully used in a streak camera to verify the synchronization of multi-channel laser on the Inertial Confinement Fusion Facility

  13. Development of intelligent control system for X-ray streak camera in diagnostic instrument manipulator

    Energy Technology Data Exchange (ETDEWEB)

    Pei, Chengquan [Key Laboratory for Physical Electronics and Devices of the Ministry of Education, Xi' an Jiaotong University, Xi' an 710049 (China); Wu, Shengli, E-mail: slwu@mail.xjtu.edu.cn [Key Laboratory for Physical Electronics and Devices of the Ministry of Education, Xi' an Jiaotong University, Xi' an 710049 (China); Tian, Jinshou [Xi' an Institute of Optics and Precision Mechanics, Chinese Academy of Sciences, Xi' an 710119 (China); Liu, Zhen [Key Laboratory for Physical Electronics and Devices of the Ministry of Education, Xi' an Jiaotong University, Xi' an 710049 (China); Fang, Yuman [Key Laboratory for Physical Electronics and Devices of the Ministry of Education, Xi' an Jiaotong University, Xi' an 710049 (China); University of the Chinese Academy of Sciences, Beijing 100039 (China); Gao, Guilong; Liang, Lingliang [Key Laboratory for Physical Electronics and Devices of the Ministry of Education, Xi' an Jiaotong University, Xi' an 710049 (China); Xi' an Institute of Optics and Precision Mechanics, Chinese Academy of Sciences, Xi' an 710119 (China); University of the Chinese Academy of Sciences, Beijing 100039 (China); Wen, Wenlong [Key Laboratory for Physical Electronics and Devices of the Ministry of Education, Xi' an Jiaotong University, Xi' an 710049 (China)

    2015-11-01

    An intelligent control system for an X ray streak camera in a diagnostic instrument manipulator (DIM) is proposed and implemented, which can control time delay, electric focusing, image gain adjustment, switch of sweep voltage, acquiring environment parameters etc. The system consists of 16 A/D converters and 16 D/A converters, a 32-channel general purpose input/output (GPIO) and two sensors. An isolated DC/DC converter with multi-outputs and a single mode fiber were adopted to reduce the interference generated by the common ground among the A/D, D/A and I/O. The software was designed using graphical programming language and can remotely access the corresponding instrument from a website. The entire intelligent control system can acquire the desirable data at a speed of 30 Mb/s and store it for later analysis. The intelligent system was implemented on a streak camera in a DIM and it shows a temporal resolution of 11.25 ps, spatial distortion of less than 10% and dynamic range of 279:1. The intelligent control system has been successfully used in a streak camera to verify the synchronization of multi-channel laser on the Inertial Confinement Fusion Facility.

  14. Global survey of malaria rapid diagnostic test (RDT) sales, procurement and lot verification practices: assessing the use of the WHO-FIND Malaria RDT Evaluation Programme (2011-2014).

    Science.gov (United States)

    Incardona, Sandra; Serra-Casas, Elisa; Champouillon, Nora; Nsanzabana, Christian; Cunningham, Jane; González, Iveth J

    2017-05-15

    Malaria rapid diagnostic tests (RDTs) play a critical role in malaria case management, and assurance of quality is a key factor to promote good adherence to test results. Since 2007, the World Health Organization (WHO) and the Foundation for Innovative New Diagnostics (FIND) have coordinated a Malaria RDT Evaluation Programme, comprising a pre-purchase performance evaluation (product testing, PT) and a pre-distribution quality control of lots (lot testing, LT), the former being the basis of WHO recommendations for RDT procurement. Comprehensive information on malaria RDTs sold worldwide based on manufacturers' data and linked to independent performance data is currently not available, and detailed knowledge of procurement practices remains limited. The use of the PT/LT Programme results as well as procurement and lot verification practices were assessed through a large-scale survey, gathering product-specific RDT sales and procurement data (2011-14 period) from a total of 32 manufacturers, 12 procurers and 68 National Malaria Control Programmes (NMCPs). Manufacturers' reports showed that RDT sales had more than doubled over the four years, and confirmed a trend towards increased compliance with the WHO procurement criteria (from 83% in 2011 to 93% in 2014). Country-level reports indicated that 74% of NMCPs procured only 'WHO-compliant' RDT products, although procurers' transactions datasets revealed a surprisingly frequent overlap of different products and even product types (e.g., Plasmodium falciparum-only and Plasmodium-pan) in the same year and country (60 and 46% of countries, respectively). Importantly, the proportion of 'non-complying' (i.e., PT low scored or not evaluated) products was found to be higher in the private health care sector than in the public sector (32% vs 5%), and increasing over time (from 22% of private sector sales in 2011 to 39% in 2014). An estimated 70% of the RDT market was covered by the LT programme. The opinion about the PT

  15. IAEA instrumentation programme keeping pace with technology

    International Nuclear Information System (INIS)

    Fortakov, V.; Rundquist, D.E.

    1995-01-01

    Nuclear components, nuclear practices and nuclear facilities have all improved with the maturing of the industry. These improvements have been driven by forces, which are beyond the normal evolutionary pressures, such as increased safety, as low as possible radiation exposure for the workers as well as for the public and the increasing competiveness of alternative forms of energy generation. International nuclear safeguards has had to keep pace with these technological and administrative changes. Moreover, the political climate has changed since the initial implementation of safeguards under the Non-Proliferation Treaty. Implementation of safeguards agreements has accommodated to these changes as well as to the technical innovations. One important component of safeguards implementation, namely the instruments deployed by inspectors, has matured with the help of Member States. Continued efforts in the development and deployment of appropriate instruments are needed to maintain an acceptable level of efficiency and credibility. (orig.)

  16. Diagnostics in the hostile environments of a prototype fusion reactor

    International Nuclear Information System (INIS)

    Osher, J.E.

    1982-01-01

    Various facets of a thermonuclear type plasma that will likely require special considerations or hardening of applied diagnostic instrumentation are reviewed. The discussion will include both on-line diagnostic instrumentation requirements for satisfactory operation and considerations to reduce integrated radiation damage sufficiently for a reasonable diagnostic lifetime. Several new diagnostics aimed specifically at measurements of the plasma characteristics most appropriate to a thermonculear reactor type plasma are discussed. This will include instrumentation needed to make quantitative energy flow measurements during long term operation with the expected high input power sources, and locally very high wall power loadings. The second part of this lecture will broaden diagnostics to include materials damage measurements needed for engineering design studies. This will include needed diagnostic instrumentation to assess first wall damage, sputtering erosion at walls (and high power beam dumps), and radiation damage to components such as insulators

  17. Radiation protection programme for planned medical exposure situation

    International Nuclear Information System (INIS)

    Hanciles, Milford

    2016-04-01

    Radiation protection programme for planned medical exposure situation which involved diagnostic and interventional radiology was discussed. The radiation protection programme (RPP) should reflect the management’s commitment to radiation protection and safety through the management structure, policies, procedures and organizational arrangement commensurate with the nature and extent of the risk. Registrants and licensees should use the RPP as a tool for the development of a safety culture in diagnostic and interventional radiology departments .Recommendations are provided which when implemented in the education and training of radiographers, referral physician and all those involved in the use of ionizing radiation for diagnosis purposes will improve protection and safety of the occupationally exposed worker, the patient, the public and the environment. (au)

  18. HIV rapid diagnostic testing by lay providers in a key population-led health service programme in Thailand.

    Science.gov (United States)

    Wongkanya, Rapeeporn; Pankam, Tippawan; Wolf, Shauna; Pattanachaiwit, Supanit; Jantarapakde, Jureeporn; Pengnongyang, Supabhorn; Thapwong, Prasopsuk; Udomjirasirichot, Apichat; Churattanakraisri, Yutthana; Prawepray, Nanthika; Paksornsit, Apiluk; Sitthipau, Thidadaow; Petchaithong, Sarayut; Jitsakulchaidejt, Raruay; Nookhai, Somboon; Lertpiriyasuwat, Cheewanan; Ongwandee, Sumet; Phanuphak, Praphan; Phanuphak, Nittaya

    2018-01-01

    Introduction:  Rapid diagnostic testing (RDT) for HIV has a quick turn-around time, which increases the proportion of people testing who receive their result. HIV RDT in Thailand has traditionally been performed only by medical technologists (MTs), which is a barrier to its being scaled up. We evaluated the performance of HIV RDT conducted by trained lay providers who were members of, or worked closely with, a group of men who have sex with men (MSM) and with transgender women (TG) communities, and compared it to tests conducted by MTs. Methods:  Lay providers received a 3-day intensive training course on how to perform a finger-prick blood collection and an HIV RDT as part of the Key Population-led Health Services (KPLHS) programme among MSM and TG. All the samples were tested by lay providers using Alere Determine HIV 1/2. HIV-reactive samples were confirmed by DoubleCheckGold Ultra HIV 1&2 and SD Bioline HIV 1/2. All HIV-positive and 10% of HIV-negative samples were re-tested by MTs using Serodia HIV 1/2. Results:  Of 1680 finger-prick blood samples collected and tested using HIV RDT by lay providers in six drop-in centres in Bangkok, Chiang Mai, Chonburi and Songkhla, 252 (15%) were HIV-positive. MTs re-tested these HIV-positive samples and 143 randomly selected HIV-negative samples with 100% concordant test results. Conclusion:  Lay providers in Thailand can be trained and empowered to perform HIV RDT as they were found to achieve comparable results in sample testing with MTs. Based on the task-shifting concept, this rapid HIV testing performed by lay providers as part of the KPLHS programme has great potential to enhance HIV prevention and treatment programmes among key at-risk populations.

  19. Thematic plan on diagnostic radiology

    International Nuclear Information System (INIS)

    2003-01-01

    Due to the vital importance of diagnostic radiology in both the diagnosis and management of disease processes, there is a need for a greater coherent international effort to help the developing nations create strategies for the incorporation of imaging into their healthcare systems. To meet the needs of such countries, a comprehensive programme is required to take into consideration the availability of local expertise (medical and technical), the infrastructure (stable electrical supply, water and air-conditioning) and the disease pattern or burden. In short, the total solution requires coordinating the International Atomic Energy Agency efforts with those of other partners. The Agency already has programmes in nuclear medicine and radiation therapy supported by activities in dosimetry and medical physics. Through the Technical Co-operation fund the Agency already supports projects in some areas of diagnostic imaging, dosimetry and radiation protection, but it lacks a comprehensive programme to provide a systematic approach focusing on the medical aspects of imaging science and including all the imaging technologies. Member States require the Agency's assistance in this area since no single UN organisation has the resources or the expertise to do the entire job without help. This document presents the proposed programme strategy and action plan

  20. Fuel-motion diagnostics and cineradiography

    International Nuclear Information System (INIS)

    DeVolpi, A.

    1982-09-01

    Nuclear and non-nuclear applications of cineradiography are reviewed, with emphasis on diagnostic instrumentation for in-pile transient-reactor safety testing of nuclear fuel motion. The primary instrument for this purpose has been the fast-neutron hodoscope, which has achieved quantitative monitoring of time, location, mass, and velocity of fuel movement under the difficult conditions associated with transient-reactor experiments. Alternative diagnostic devices that have been developed have not matched the capabilities of the hodoscope. Other applications for the fuel-motion diagnostic apparatus are also evolving, including time-integrated radiography and direct time- and space-resolved fuel-pin power monitoring. Although only two reactors are now actively equipped with high-resolution fuel-motion diagnostic systems, studies and tests have been carried out in and for many other reactors

  1. Diagnostic development and support of MHD test facilities

    Energy Technology Data Exchange (ETDEWEB)

    1990-01-01

    The Diagnostic Instrumentation and Analysis Laboratory (DIAL) at Mississippi State University (MSU) is developing diagnostic instruments for MHD power train data acquisition and for support of MHD component development test facilities. Microprocessor-controlled optical instruments, initially developed for Heat Recovery/Seed Recovery support, are being refined, and new systems to measure temperatures and gas-seed-slag stream characteristics are being developed. To further data acquisition and analysis capabilities, the diagnostic systems are being interfaced with DIAL's computers. Technical support for the diagnostic needs of the national MHD research effort is being provided. DIAL personnel will also cooperate with government agencies and private industries to improve the transformation of research and development results into processes, products and services applicable to their needs. 25 figs., 6 tabs.

  2. Diagnostic development and support of MHD test facilities

    International Nuclear Information System (INIS)

    Shepard, W.S.; Cook, R.L.

    1990-01-01

    The Diagnostic Instrumentation and Analysis Laboratory (DIAL) at Mississippi State University (MSU) is developing diagnostic instruments for MHD power train data acquisition and for support of MHD component development test facilities. Microprocessor-controlled optical instruments, initially developed for Heat Recovery/ Seed Recovery support, are being refined, and new systems to measure temperatures and gas-seed-slag stream characteristics are being developed. To further data acquisition and analysis capabilities, the diagnostic systems are being interfaced with DIAL's computers. Technical support for the diagnostic needs of the national MHD research effort is being provided. DIAL personnel will also cooperate with government agencies and private industries to improve the transformation of research and development results into processes, products and services applicable to their needs

  3. High precision instrumentation for measuring the true exposure time in diagnostic X-ray examinations

    International Nuclear Information System (INIS)

    Silva, Danubia B.; Santos, Marcus A.P.; Barros, Fabio R.; Santos, Luiz A.P.

    2013-01-01

    One of the most important physical quantities to be evaluated in diagnostic radiology is the radiation exposure time experimented by the patient during the X-ray examination. IAEA and WHO organizations have suggested that any country must create a quality surveillance program to verify if each type of ionizing radiation equipment used in the hospitals and medical clinics are in conformity with the accepted uncertainties following the international standards. The purpose of this work is to present a new high precision methodology for measuring true exposure time in diagnostic X-ray examinations: pulsed, continuous or digital one. An electronic system named CronoX, which will be soon registered at the Brazilian Patent Office (INPI), is the equipment that provides such a high precision measurement. The principle of measurement is based on the electrical signal captured by a sensor that enters in a regeneration amplifier to transform it in a digital signal, which is treated by a microprocessor (uP). The signal treatment results in a two measured times: 1) T rx , the true X-ray exposure time; 2) T nx , the time in which the X-ray machine is repeatedly cut off during the pulsed irradiation and there is no delivery dose to the patient. Conventional Polymat X-ray equipment and dental X-ray machines were used to generate X-ray photons and take the measurements with the electronic systems. The results show that such a high precision instrumentation displays the true exposure time in diagnostic X-ray examinations and indicates a new method to be purposed for the quality surveillance programs in radiology. (author)

  4. Programmable pulse generator

    International Nuclear Information System (INIS)

    Xue Zhihua; Lou Binqiao; Duan Xiaohui

    2002-01-01

    The author introduces the design of programmable pulse generator that is based on a micro-controller and controlled by RS232 interface of personal computer. The whole system has good stability. The pulse generator can produce TTL pulse and analog pulse. The pulse frequency can be selected by EPLD. The voltage amplitude and pulse width of analog pulse can be adjusted by analog switches and digitally-controlled potentiometers. The software development tools of computer is National Instruments LabView5.1. The front panel of this virtual instrumentation is intuitive and easy-to-use. Parameters can be selected and changed conveniently by knob and slide

  5. Molecular diagnostics for low resource settings

    Science.gov (United States)

    Weigl, Bernhard H.

    2010-03-01

    As traditional high quality diagnostic laboratories are not widely available or affordable in developing country health care settings, microfluidics-based point-of-care diagnostics may be able to address the need to perform complex assays in under-resourced areas. Many instrument-based as well as non-instrumented microfluidic prototype diagnostics are currently being developed. In addition to various engineering challenges, the greatest remaining issue is the search for truly low-cost disposable manufacturing methods. Diagnostics for global health, and specifically microfluidics and molecular-based low resource diagnostics, have become a very active research area over the last five years, thanks in part to new funding that became available from the Bill and Melinda Gates Foundation, the National Institutes of Health, and other sources. This has led to a number of interesting prototype devices that are now in advanced development or clinical validation. These devices include disposables and instruments that perform multiplexed PCR-based lab-on-a-chips for enteric, febrile, and vaginal diseases, as well as immunoassays for diseases such as malaria, HIV, and various sexually transmitted diseases. More recently, instrument-free diagnostic disposables based on isothermal nucleic acid amplification have been developed as well. Regardless of platform, however, the search for truly low-cost manufacturing methods that would result in cost of goods per disposable of around US1/unit at volume remains a big challenge. This talk will give an overview over existing platform development efforts as well as present some original research in this area at PATH.

  6. MFTF-B plasma-diagnostic system

    International Nuclear Information System (INIS)

    Throop, A.L.; Goerz, D.A.; Thomas, S.R.

    1981-01-01

    This paper describes the current design status of the plasma diagnostic system for MFTF-B. In this paper we describe the system requirement changes which have occurred as a result of the funded rescoping of the original MFTF facility into MFTF-B. We outline the diagnostic instruments which are currently planned, and present an overview of the diagnostic system

  7. Life Cycle V and V Process for Hardware Description Language Programs of Programmable Logic Device-based Instrumentation and Control Systems

    International Nuclear Information System (INIS)

    Cha, K. H.; Lee, D. Y.

    2010-01-01

    Programmable Logic Device (PLD), especially Complex PLD (CPLD) or Field Programmable Logic Array (FPGA), has been growing in interest in nuclear Instrumentation and Control (I and C) applications. PLD has been applied to replace an obsolete analog device or old-fashioned microprocessor, or to develop digital controller, subsystem or overall system on hardware aspects. This is the main reason why the PLD-based I and C design provides higher flexibility than the analog-based one, and the PLD-based I and C systems shows better real-time performance than the processor-based I and C systems. Due to the development of the PLD-based I and C systems, their nuclear qualification has been issued in the nuclear industry. Verification and Validation (V and V) is one of necessary qualification activities when a Hardware Description Language (HDL) is used to implement functions of the PLD-based I and C systems. The life cycle V and V process, described in this paper, has been defined as satisfying the nuclear V and V requirements, and it has been applied to verify Correctness, Completeness, and Consistency (3C) among design outputs in a safety-grade programmable logic controller and a safety-critical data communication system. Especially, software engineering techniques such as the Fagan Inspection, formal verification, simulated verification and automated testing have been defined for the life cycle V and V tasks of behavioral, structural, and physical design in VHDL

  8. Secondary prevention at 360°: the important role of diagnostic imaging.

    Science.gov (United States)

    Ciarrapico, Anna Micaela; Manenti, Guglielmo; Pistolese, Chiara; Fabiano, Sebastiano; Fiori, Roberto; Romagnoli, Andrea; Sergiacomi, Gianluigi; Stefanini, Matteo; Simonetti, Giovanni

    2015-06-01

    The aim of this paper is to underline the importance of the role of general practitioners (GPs) in distributing vital information about prevention to citizens, to highlight the importance of the so-called voluntary prevention programmes, both for conditions for which no organised screening programmes exist and for those for which they do exist but may well be obsolete or inefficient. Nowadays, voluntary prevention is made more effective thanks to the new sophisticated diagnostic technologies applied worldwide by diagnostic imaging. Epidemiological data about the incidence and causes of death among the Italian population have shown that screening programmes should be aimed first at fighting the following diseases: prostatic carcinoma, lung cancer, colorectal carcinoma, breast cancer, cardiovascular disease, cerebrovascular disease, aortic and peripheral vascular disease. GPs do not generally give good or adequate instructions concerning voluntary prevention programmes; GPs may not even be aware of this type of prevention which could represent a valuable option together with the existing mass screening programmes. Therefore, in the following analysis, we aim to outline the correct diagnostic pathway for the prevention of diseases having the highest incidence in our country and which represent the most frequent causes of death. If used correctly, these screening programmes may contribute to the success of secondary prevention, limiting the use of tertiary prevention and thus producing savings for the Italian National Health System.

  9. The FAO/IAEA External Quality Assurance Programme (EQAP) and movement towards a generic veterinary diagnostic testing laboratory accreditation scheme. Report of an FAO/IAEA consultants meeting

    International Nuclear Information System (INIS)

    2002-01-01

    FAO/IAEA support in the area of animal health is focused on enhancing the ability of regional reference laboratories and national veterinary authorities in developing countries to diagnose livestock diseases of major importance using nuclear and related technologies, and to help monitor the effectiveness of national and regional intervention strategies. This is done through provision of advice to the veterinary authorities concerning the development of appropriate sampling or research strategies coupled with FAO/IAEA-led collaborative development, adaptation, standardization, evaluation, and provision of quality-controlled enzyme-linked immunosorbent assay (ELISA) kits and the components necessary for diagnostic application of the polymerase chain reaction (PCR) techniques. Additional features of FAO/IAEA animal health support include provision of relevant laboratory equipment, training of counterpart scientists and technicians in the use of the equipment and standardized assays, and coordination of quality assurance (QA) programmes to monitor the proficiency of the assayists and help evaluate the impact of improved diagnostic capabilities. The current FAO/IAEA External Quality Assurance Programme (EQAP) for Animal Disease Diagnosis began as an effort to monitor the efficacy of mass vaccination programmes as part of the Pan African Rinderpest Campaign (PARC). Proficiency test panels, composed of 40 'unknown' serum samples, were sent to participating laboratories yearly to measure their abilities with ELISA in distinguishing between samples that were positive or negative for rinderpest antibodies. From this beginning, the EQAP has grown into an effort to measure general and specific components of FAO/IAEA counterparts' QA systems and provide assurance to outside observers that the use of FAO/IAEA diagnostic ELISA's are within established control limits and the test results and diagnostic interpretations are reliable. A major objective of the current EQAP is to

  10. Creating a Super Instrument

    DEFF Research Database (Denmark)

    Kallionpää, Maria; Gasselseder, Hans-Peter

    2015-01-01

    Thanks to the development of new technology, musical instruments are no more tied to their existing acoustic or technical limitations as almost all parameters can be augmented or modified in real time. An increasing number of composers, performers, and computer programmers have thus become intere...

  11. Programmable dc motor controller

    Science.gov (United States)

    Hopwood, J. E.

    1982-11-01

    A portable programmable dc motor controller, with features not available on commercial instruments was developed for controlling fixtures during welding processes. The controller can be used to drive any dc motor having tachometer feedback and motor requirements not exceeding 30 volts, 3 amperes. Among the controller's features are delayed start time, upslope time, speed, and downslope time.

  12. Summary and conclusions of Conference in SAVE programme: For millennium of energetic efficiency

    International Nuclear Information System (INIS)

    1999-01-01

    SAVE is general programme of society which tendency is to improve energy efficiency in all sectors of consumption. it seems to be a necessary instrument for Kyoto protocol purposes, specially CO 2 emission reduction. SAVE Programme will become very soon a part of Energy Framework Programme containing several energy programmes including SAVE and ALTENER with tendency to improve coordination and transparency among contents

  13. In-bore instrumentation/diagnostics for large-bore EMLs

    International Nuclear Information System (INIS)

    Fernandez, M.J.; Ager, S.A.; Hudson, R.D.

    1991-01-01

    This paper reports on a flying laboratory technique of in-bore diagnostics for large-bore electromagnetic launchers (EMLs). The high pressure, heat, and magnetic flux environment of the EML and its containment structures do not allow easy implementation of conventional diagnostic techniques. Researchers have relied on remote sensing methods, such as B probes (isolated from the bore), for data. The accuracy and relevance of such discrete, remote measurement is somewhat questionable. An in-house program has been initiated to determine the feasibility of making measurement of EML parameters on board a projectile. This technique utilizes off-the-shelf components in a configuration that has been proven effective in measuring projectile acceleration in the bore of propellant driven guns

  14. [Controlling instruments in radiology].

    Science.gov (United States)

    Maurer, M

    2013-10-01

    Due to the rising costs and competitive pressures radiological clinics and practices are now facing, controlling instruments are gaining importance in the optimization of structures and processes of the various diagnostic examinations and interventional procedures. It will be shown how the use of selected controlling instruments can secure and improve the performance of radiological facilities. A definition of the concept of controlling will be provided. It will be shown which controlling instruments can be applied in radiological departments and practices. As an example, two of the controlling instruments, material cost analysis and benchmarking, will be illustrated.

  15. Modular beam diagnostics instrument design for Cyclotrons

    International Nuclear Information System (INIS)

    Chaddha, N.; Bhole, R.B.; Sahoo, S.; Nandy, P.P.; Pal, S.

    2012-01-01

    The Cyclotrons at VECC, Kolkata i.e. Room Temperature Cyclotron (RTC) and Superconducting Cyclotron (SCC) comprise of internal and external Beam Diagnostic systems. These systems provide the beam developer with position, intensity, beam profile, a visual impression of the size and shape of ion beam, and operational control over diagnostic components like 3-finger probe, Beam Viewer probe, Deflector probe, Faraday cup, X-Y slit, Beam viewer etc. Automation of these components was initially done using customised modules for individual sub-system. An expansion of this facility and various levels of complexity demand modular design to cater easy modification and upgradation. The overall requirements are analysed and modular cards are developed based on basic functionalities like valve operation, probe/slit/viewer control, position read-out, Interlock, aperture control of beam line and communication. A 32-bit Advanced RISC Machine (ARM) based card with embedded EPICS is chosen as the master controller and FPGA/microcontroller is used for functional modules. The paper gives a comprehensive description of all modules and their integration with the control system. (author)

  16. Instrumentation requirements from the user's view

    International Nuclear Information System (INIS)

    Harsha, P.T.

    1988-01-01

    The use of combustor diagnostics is considered from the point of view of demonstration of performance of an airbreathing hypersonic engine. The basic need is seen to be that of providing the data necessary to verify performance predictions for the engine as installed in the airplane. This necessitates the use of a diagnostics capability that can provide the inputs required by the computational analyses that will be used to assess this performance. Because of the cost of ground test facilities, a premium is placed on measurement technique reliability and redundancy of instrumentation. A mix of nonintrusive optical techniques and probe-based measurements is seen to be the best approach using current diagnostics capability; one such instrument mix is outlined for a ramjet/scramjet test program. 11 references

  17. Evaluating the Relational Coordination instrument

    DEFF Research Database (Denmark)

    Edwards, Kasper; Lundstrøm, Sanne Lykke

    2014-01-01

    consistency, interrater agreement and reliability, structural validity, content validity. However as relational coordination is being used as a diagnostics tool it is important to examine further if the instrument can measure changes. Indeed we need to know how precise and sensitive the instrument is when....... We distinguish between statistical and clinical significance. Statistical significance is calculated using T-test. Clinical significance is the minimal amount of change in relational coordination score that is not considered noise. Sensitivity of the instrument i.e. the ability of the instrument...

  18. Target Diagnostics Supports NIF's Path to Ignition

    International Nuclear Information System (INIS)

    Shelton, R.

    2011-01-01

    the RAGS system. Three new instrument controllers were developed and commissioned to support this diagnostic. A residual-gas analyzer (RGA) instrument measures the gas content at various points in the system. The Digital Gamma Spectrometer instrument measures the radiological spectrum of the decaying gas isotopes. A final instrument controller was developed to interface to a PLC based Gas collection system. In order to support the implosion velocity measurements an additional Gated X-ray Detector (GXD) diagnostic was tested and commissioned. This third GXD views the target through a slit contained in its snout and allows the other GXD diagnostics to be used for measuring the shape on the same shot. In order to measure the implosion shape in a high neutron environment, Actide Readout In A Neutron Environment (ARIANE) and Neutron Imaging (NI) diagnostics were commissioned. The controls for ARIANE, a fixed port gated x-ray imager, contain a neutron shielded camera and micro channel plate pulser with its neutron sensitive electronics located in the diagnostic mezzanine. The NI diagnostic is composed of two Spectral Instruments SI-1000 cameras located 20M from the target and provides neutron images of the DT hot spot for high yield shots. The development and commissioning of these new or enhanced diagnostics in FY11 have provided meaningful insight that facilitates the optimization of the four key Ignition variables. In FY12 they will be adding three new diagnostics and enhancing four existing diagnostics in support of the continuing optimization series of campaigns.

  19. Use of the target diagnostic control system in the National Ignition Facility

    Energy Technology Data Exchange (ETDEWEB)

    Shelton, R; Lagin, L; Nelson, J

    2011-07-25

    The extreme physics of targets shocked by NIF's 192-beam laser are observed by a diverse suite of diagnostics including optical backscatter, time-integrated, time resolved and gated X-ray sensors, laser velocity interferometry, and neutron time of flight. Diagnostics to diagnose fusion ignition implosion and neutron emissions have been developed. A Diagnostic Control System (DCS) for both hardware and software facilitates development and eases integration. Each complex diagnostic typically uses an ensemble of electronic instruments attached to sensors, digitizers, cameras, and other devices. In the DCS architecture each instrument is interfaced to a low-cost Window XP processor and Java application. Instruments are aggregated as needed in the supervisory system to form an integrated diagnostic. The Java framework provides data management, control services and operator GUI generation. During the past several years, over thirty-six diagnostics have been deployed using this architecture in support of the National Ignition Campaign (NIC). The DCS architecture facilitates the expected additions and upgrades to diagnostics as more experiments are performed. This paper presents the DCS architecture, framework and our experiences in using it during the NIC to operate, upgrade and maintain a large set of diagnostic instruments.

  20. Use of the target diagnostic control system in the National Ignition Facility

    International Nuclear Information System (INIS)

    Shelton, R.; Lagin, L.; Nelson, J.

    2011-01-01

    The extreme physics of targets shocked by NIF's 192-beam laser are observed by a diverse suite of diagnostics including optical backscatter, time-integrated, time resolved and gated X-ray sensors, laser velocity interferometry, and neutron time of flight. Diagnostics to diagnose fusion ignition implosion and neutron emissions have been developed. A Diagnostic Control System (DCS) for both hardware and software facilitates development and eases integration. Each complex diagnostic typically uses an ensemble of electronic instruments attached to sensors, digitizers, cameras, and other devices. In the DCS architecture each instrument is interfaced to a low-cost Window XP processor and Java application. Instruments are aggregated as needed in the supervisory system to form an integrated diagnostic. The Java framework provides data management, control services and operator GUI generation. During the past several years, over thirty-six diagnostics have been deployed using this architecture in support of the National Ignition Campaign (NIC). The DCS architecture facilitates the expected additions and upgrades to diagnostics as more experiments are performed. This paper presents the DCS architecture, framework and our experiences in using it during the NIC to operate, upgrade and maintain a large set of diagnostic instruments.

  1. 21 CFR 876.1075 - Gastroenterology-urology biopsy instrument.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Gastroenterology-urology biopsy instrument. 876... SERVICES (CONTINUED) MEDICAL DEVICES GASTROENTEROLOGY-UROLOGY DEVICES Diagnostic Devices § 876.1075 Gastroenterology-urology biopsy instrument. (a) Identification. A gastroenterology-urology biopsy instrument is a...

  2. TFTR diagnostic vacuum controller

    International Nuclear Information System (INIS)

    Olsen, D.; Persons, R.

    1981-01-01

    The TFTR diagnostic vacuum controller (DVC) provides in conjunction with the Central Instrumentation Control and Data Acquisition System (CICADA), control and monitoring for the pumps, valves and gauges associated with each individual diagnostic vacuum system. There will be approximately 50 systems on TFTR. Two standard versions of the controller (A and B) wil be provided in order to meet the requirements of two diagnostic manifold arrangements. All pump and valve sequencing, as well as protection features, will be implemented by the controller

  3. Proceedings of symposium on intelligent nuclear instrumentation-2001

    International Nuclear Information System (INIS)

    Kataria, S.K.; Vaidya, P.P.; Das, Debashis; Narurkar, P.V.

    2001-02-01

    Advances in the field of instrumentation are relevant to many areas of importance such as nuclear and accelerator based research, reactor monitoring and control, non-destructive testing and evaluation, laser programme and health and environment monitoring etc. The nuclear instrumentation is a specialized field with very specific expertise in detection, processing and its analysis. The symposium covers various fields of nuclear interest such as radiation detectors, application of ASICs and FPGA in instruments, field instruments, nuclear instrumentation for basic research, accelerator, reactor, health and environmental monitoring instrumentation, medical instrumentation, instrument net working inclusive of field buses, WEB based and wireless technologies, software tools, AI technique in instrumentation etc., in this specialized area. Papers relevant to INIS are indexed separately

  4. Development of JT-60 diagnostics system

    International Nuclear Information System (INIS)

    Suzuki, Yasuo

    1988-01-01

    The various kinds of plasma diagnostics have been developed and utilized in the JT-60 experiments. The features of JT-60 diagnostics system and the historical proceeding of the development are described in this paper. Taking account of the design consideration, JT-60 diagnostics system is sorted out into eight groups, which include six diagnostics systems, the data processing system and diagnostics supporting system. The all devices in the JT-60 diagnostics system were instrumented on schedule in the end of the fiscal year of 1985 and have contributed to JT-60 experiments. (author)

  5. The application of automated deductive reasoning to power plant diagnostics

    International Nuclear Information System (INIS)

    Filshtein, E.L.; Rzasa, P.W.

    1986-01-01

    A module which incorporates the application of deductive reasoning to diagnostics has been developed. This module is a part of a generic diagnostic expert system prototype developed for power plant operations at Combustion Engineering. This paper is one of a series of papers which will describe the activities of the project. Specifically, this paper describes the deductive reasoning module which determines and classifies root cause malfunctions. The concept of 'perfect instruments' is introduced. These instruments are imaginary instruments which bridge the gap between real world inputs and the generic diagnostic shell. The prototype, its application, and future developments are discussed

  6. Radiochemistry programme biennial progress report (1986 and 1987)

    International Nuclear Information System (INIS)

    1988-01-01

    This biennial report covers the calendar years 1986 and 1987. This period has seen significant growth in the research activities of the Radiochemistry Programme and this is reflected in this report. The report is organised subject-wise into sections dealing with Fuel Chemistry and Thermodynamics, Sodium Chemistry, Analytical Chemistry and Instrumentation. The major part of the activities of the Radiochemistry Programme relates to fuel chemistry including thermophysical and thermodynamic properties of fuel materials, chemistry of fuel reprocessing and facilities as well as techniques for post-irradiation studies. Sodium chemistry is a smaller but important R and D activity, which has reached full maturity during the period of this report. Analytical chemistry and instrumentation are essential supporting activities. The rapid progress made over the last two years are reflected in the number of items covered in this report. In order to keep the total length of this report under control, the editors had to restrict the individual activities to one or two pages. Though the details of various studies are not presented here, it is hoped that the report gives an overview of the progress made by the Radiochemistry Programme in the last two years. The list of publications given at the end also reflects the growth in research programmes. (author)

  7. Construction of programmable interconnected 3D microfluidic networks

    International Nuclear Information System (INIS)

    Hunziker, Patrick R; Wolf, Marc P; Wang, Xueya; Zhang, Bei; Marsch, Stephan; Salieb-Beugelaar, Georgette B

    2015-01-01

    Microfluidic systems represent a key-enabling platform for novel diagnostic tools for use at the point-of-care in clinical contexts as well as for evolving single cell diagnostics. The design of 3D microfluidic systems is an active field of development, but construction of true interconnected 3D microfluidic networks is still a challenge, in particular when the goal is rapid prototyping, accurate design and flexibility. We report a novel approach for the construction of programmable 3D microfluidic systems consisting of modular 3D template casting of interconnected threads to allow user-programmable flow paths and examine its structural characteristics and its modular function. To overcome problems with thread template casting reported in the literature, low-surface-energy polymer threads were used, that allow solvent-free production. Connected circular channels with excellent roundness and low diameter variability were created. Variable channel termination allowed programming a flow path on-the-fly, thus rendering the resulting 3D microfluidic systems highly customizable even after production. Thus, construction of programmable/reprogrammable fully 3D microfluidic systems by template casting of a network of interconnecting threads is feasible, leads to high-quality and highly reproducible, complex 3D geometries. (paper)

  8. Advances in Miniaturized Instruments for Genomics

    Directory of Open Access Journals (Sweden)

    Cihun-Siyong Alex Gong

    2014-01-01

    Full Text Available In recent years, a lot of demonstrations of the miniaturized instruments were reported for genomic applications. They provided the advantages of miniaturization, automation, sensitivity, and specificity for the development of point-of-care diagnostics. The aim of this paper is to report on recent developments on miniaturized instruments for genomic applications. Based on the mature development of microfabrication, microfluidic systems have been demonstrated for various genomic detections. Since one of the objectives of miniaturized instruments is for the development of point-of-care device, impedimetric detection is found to be a promising technique for this purpose. An in-depth discussion of the impedimetric circuits and systems will be included to provide total consideration of the miniaturized instruments and their potential application towards real-time portable imaging in the “-omics” era. The current excellent demonstrations suggest a solid foundation for the development of practical and widespread point-of-care genomic diagnostic devices.

  9. Nova target diagnostics control system

    International Nuclear Information System (INIS)

    Severyn, J.R.

    1985-01-01

    During the past year the Nova target diagnostics control system was finished and put in service. The diagnostics loft constructed to the north of the target room provides the environmental conditions required to collect reliable target diagnostic data. These improvements include equipment cooling and isolation of the power source with strict control of instrumentation grounds to eliminate data corruption due to electromagnetic pulses from the laser power-conditioning system or from target implosion effects

  10. The Added Value of the Combined Use of the Autism Diagnostic Interview-Revised and the Autism Diagnostic Observation Schedule: Diagnostic Validity in a Clinical Swedish Sample of Toddlers and Young Preschoolers

    Science.gov (United States)

    Zander, Eric; Sturm, Harald; Bölte, Sven

    2015-01-01

    The diagnostic validity of the new research algorithms of the Autism Diagnostic Interview-Revised and the revised algorithms of the Autism Diagnostic Observation Schedule was examined in a clinical sample of children aged 18-47 months. Validity was determined for each instrument separately and their combination against a clinical consensus…

  11. Dynamic Visualization of SNS Diagnostics Summary Report and System Status

    CERN Document Server

    Blokland, Willem; Long, Cary D; Murphy, Darryl J; Purcell, John D; Sundaram, Madhan

    2005-01-01

    The Spallation Neutron Source (SNS) accelerator systems will deliver a 1.0 GeV, 1.4 MW proton beam to a liquid mercury target for neutron scattering research. The accelerator complex consists of a 1 GeV linear accelerator, an accumulator ring and associated transport lines. The SNS diagnostics platform is PC-based running Embedded Windows XP and LabVIEW. The diagnostics instruments communicate with the control system using the Channel Access (CA) protocol of the Experimental Physics and Industrial Control System (EPICS). This paper describes the Diagnostics Group's approach to collecting data from the instruments, processing it, and presenting live in a summarized way over the web. Effectively, adding a supervisory level to the diagnostics instruments. One application of this data mining is the "Diagnostics Status Page" that summarizes the insert-able devices, transport efficiencies, and the mode of the accelerator in a compact webpage. The displays on the webpage change automatically to show the latest and/o...

  12. Quality assurance programme for screen film mammography

    International Nuclear Information System (INIS)

    2009-01-01

    The application of radiation in human health, for both the diagnosis and treatment of disease, is an important component of the work of the IAEA. In the area of diagnostic radiology, this work is focused on quality assurance methods to both the promotion of the effective use of radiation for diagnostic outcome, through achieving and maintaining appropriate image quality, and also on dose determination to allow the monitoring and reduction of dose to the patient. In response to heightened awareness of the importance of patient dose contributed by radiology procedures, the IAEA published Dosimetry in Diagnostic Radiology: An International Code of Practice (Technical Reports Series No. 457) in 2007, to form a basis for patient dose determination for the Member States. Further to this, it is recognized that for complex diagnostic procedures, such as mammography, a detailed guidance document is required to give the professionals in the clinical centre the knowledge necessary to assess the patient dose, as well as to ensure that the procedure gives the maximal patient benefit possible. It is well documented that without the implementation of a quality culture and a systematic quality assurance programme with appropriate education, the detection of breast cancer cannot be made at an early enough stage to allow effective curative treatment to be undertaken. Currently there are a number of established quality assurance protocols in mammography from national and regional institutions, however, many of these protocols are distinctive and so a harmonized approach is required. This will allow the Member States to facilitate quality assurance in mammography in a standardized way which will also facilitate the introduction of national quality assurance programmes that are needed to underpin effective population screening programmes for breast cancer. Development of a quality assurance document for screen film mammography was started in 2005 with the appointment of a drafting

  13. Diagnostic examination of the urethra in the female and double-balloon urethrography as a diagnostic method

    International Nuclear Information System (INIS)

    Madeja, C.; Mutze, S.; Poetzschke, B.; Tunn, R.; Heinrich, G.; Hamm, B.

    1997-01-01

    The double-balloon urethrography can be recommended as an efficient diagnostic method for examination of the urethra in the female patient. Because of its improved controllability, retrograde application of the contrast agent is superior to other techniques. Complications can be avoided by maintaining constant pressure during contrast agent application. The few commercially available double-balloon instruments suffer from a number of deficiencies which are the reason for this technique having met with low acceptance, thus being only rarely applied. In addition, application of the instrument is not easy. Nevertheless, this diagnostic technique would deserve much more frequent application. (orig.) [de

  14. Recent advances in radiation protection instrumentation

    International Nuclear Information System (INIS)

    Babu, D.A.R.

    2012-01-01

    Radiation protection instrumentation plays very important role in radiation protection and surveillance programme. Radiation detector, which appears at the frontal end of the instrument, is an essential component of these instruments. The instrumental requirement of protection level radiation monitoring is different from conventional radiation measuring instruments. Present paper discusses the new type of nuclear radiation detectors, new protection level instruments and associated electronic modules for various applications. Occupational exposure to ionizing radiation can occur in a range of industries, such as nuclear power plants; mining and milling; medical institutions; educational and research establishments; and nuclear fuel cycle facilities. Adequate radiation protection to workers is essential for the safe and acceptable use of radioactive materials for different applications. The radiation exposures to the individual radiation workers and records of their cumulative radiation doses need to be routinely monitored and recorded

  15. NIF diagnostic damage and design issues

    International Nuclear Information System (INIS)

    Landen, N.

    1999-01-01

    The NIF target environment is evaluated with respect to target and diagnostic debris and with respect to instrument survivability in the presence of target debris and radiation. Quantitative estimates are arrived at by extrapolating from Nova and Omega experience using simple scaling arguments. Specifically, we evaluate the closest distance of approach of various components of DIM-based diagnostics such as target mounted pinhole arrays, open detectors, filters, x-ray optics, and spectrometers. We also include constraints on achieving adequate signal-to-noise on x-ray diagnostics. Four of the most important conclusions are as follows: (1) The required full NIF stand-off distance for heavily filtered detectors (e.g. multi-keV x-ray and particle detectors) as determined by concerns of diagnostic debris and diagnostic survivability to debris and radiation is no more than 100 cm. (2) Target mounted pinhole arrays and slits mounted a few cm from chamber center at NIF will survive long enough to record data and should be an acceptable source of shrapnel debris. (3) DIM-based instrument stand-off distances are compatible with achieving the same photon statistics (or better with ongoing improvements in detector resolution and noise) than available with current Nova and Omega SIM- or TIM-based instrumentation. Section II reviews target and diagnostic debris with respect to final optics. Section III reviews debris and radiation with respect to all diagnostic components. The following laser scaling between Nova/Omega and NIF is used throughout unless otherwise specified: laser energy E = 100x, drive duration τ = 6x and hence for a given laser intensity or hohlraum temperature, target size r approximately √(E/τ) = 4x. The 100x increase in E accounts for the fact that many Nova shots were performed with only 20 kJ and all LLNL Omega shots were performed with only 15 kJ

  16. [work motivation -- assessment instruments and their relevance for medical care].

    Science.gov (United States)

    Fiedler, Rolf G; Ranft, Andreas; Greitemann, Bernhard; Heuft, Gereon

    2005-11-01

    The relevance of work motivation for medical research and healthcare, in particular rehabilitation, is described. Four diagnostic instruments in the German language are introduced which can assess work motivation using a scale system: AVEM, JDS, LMI and FBTM. Their possible application and potential usage for the clinical area are discussed. Apart from the FBTM, none of these instruments can be directly used as a general instrument in a normal medical clinical setting. Finally, a current model for work motivation (compensatory model of work motivation and volition) is presented that contains basis concepts, which are judged as important for future research questions concerning the development of motivation diagnostic instruments.

  17. 2002 Conference Programme and Book of Abstracts

    International Nuclear Information System (INIS)

    2002-01-01

    The 25th Annual (Silver Jubilee) Conference 2002 Conference Programme and Book of Abstracts gives a brief on the Nigerian Institute of Physics, the Sheda Science and Technology Complex. It carries the Conference programme and carries the abstracts of all the papers presented. The abstracts cover a wide range of subjects including topics in atmospheric physics, education, policy and planning, geophysics, instrumentation, mathematical sciences, theoretical physics, nuclear and health physics, solid state, electronic and health physics. We are grateful to the Nigerian Institute of Physics for this volume

  18. Diagnostics for a coal-fired MHD retrofit of an existing power station

    Energy Technology Data Exchange (ETDEWEB)

    Cook, R L; Shepard, W S [Mississippi State Univ. (USA). Diagnostic Instrumentation and Analysis Lab.

    1990-01-01

    MHD flows represent one of the most severe environments encountered by gasdynamic diagnostics. Special state-of-the-art techniques and instrumentation systems are required to monitor and collect data for the MHD components, and these diagnostic systems must operate under very severe environmental and magnetic field conditions. The Diagnostic Instrumentation and Analysis Laboratory (DIAL) at Mississippi State University has developed, and is continuing to develop, advanced optical diagnostic techniques and instrumentation systems to provide nonintrusive, remote real-time measurements and to operate successfully in the industrial-like environment of a large-scale MHD retrofit power station. Such diagnostic instrumentation can provide the information to completely evaluate the performance of individual components, as well as, the entire power plant. It is essential to determine as much detail as possible about the various component operations in an MHD retrofit system so that a commercial plant design can be optimized quickly. This paper discusses the instrumentation systems which DIAL proposed for an MHD retrofit of an existing power station. Instruments which have been making measurements on the U.S. MHD test facilities for several years are presented, along with instruments which will be available within two years. Parameters to be measured along with location and frequency are discussed in detail. These parameters include electron density, electrical conductivity, K-atom density, gas temperature, gas velocity, temperature and velocity profiles, gas composition, and particle size, number, density and distrib00000

  19. Diagnostics in Japan's microgravity experiments

    Science.gov (United States)

    Kadota, Toshikazu

    1995-01-01

    The achievement of the combustion research under microgravity depends substantially on the availability of diagnostic systems. The non-intrusive diagnostic systems are potentially applicable for providing the accurate, realistic and detailed information on momentum, mass and energy transport, complex gas phase chemistry, and phase change in the combustion field under microgravity. The non-intrusive nature of optical instruments is essential to the measurement of combustion process under microgravity which is very nervous to any perturbation. However, the implementation of the non-intrusive combustion diagnostic systems under microgravity is accompanied by several constraints. Usually, a very limited space is only available for constructing a highly sophisticated system which is so sensitive that it is easily affected by the magnitude of the gravitational force, vibration and heterogeneous field of temperature and density of the environments. The system should be properly adjusted prior to the experiment. Generally, it is quite difficult to tune the instruments during measurements. The programmed sequence of operation should also be provided. Extensive effort has been toward the development of non-intrusive diagnostic systems available for the combustion experiments under microgravity. This paper aims to describe the current art and the future strategy on the non-intrusive diagnostic systems potentially applicable to the combustion experiments under microgravity in Japan.

  20. Energy Management Programmes for Industry

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2012-09-05

    The IEA Policy Pathway publications provide details on how to implement specific recommendations drawn from the IEA 25 Energy Efficiency Policy Recommendations. This Policy Pathway, jointly produced by the International Energy Agency and the Institute for Industrial Productivity, develops the critical steps for policy makers implementing energy management programmes for industry. Optimising energy use in industry is essential to improve industrial competitiveness and achieve wider societal goals such as energy security, economic recovery and development, climate change mitigation and environmental protection. While there is significant potential to decrease energy consumption in this sector, opportunities to improve energy efficiency are still under-exploited. Energy management programmes have shown to be instrumental in addressing many of the barriers that inhibit wide-scale uptake of energy management in industry. The Policy Pathway builds on lessons learned from country experiences and provides actionable guidance on how to plan and design, implement, evaluate and monitor energy management programmes for industry.

  1. 21 CFR 201.119 - In vitro diagnostic products.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 4 2010-04-01 2010-04-01 false In vitro diagnostic products. 201.119 Section 201...) DRUGS: GENERAL LABELING Exemptions From Adequate Directions for Use § 201.119 In vitro diagnostic products. (a) “In vitro diagnostic products” are those reagents, instruments and systems intended for use...

  2. SNS Diagnostics Timing Integration

    CERN Document Server

    Long, Cary D; Murphy, Darryl J; Pogge, James; Purcell, John D; Sundaram, Madhan

    2005-01-01

    The Spallation Neutron Source (SNS) accelerator systems will deliver a 1.0 GeV, 1.4 MW proton beam to a liquid mercury target for neutron scattering research. The accelerator complex consists of a 1 GeV linear accelerator, an accumulator ring and associated transport lines. The SNS diagnostics platform is PC-based running Windows XP Embedded for its OS and LabVIEW as its programming language. Coordinating timing among the various diagnostics instruments with the generation of the beam pulse is a challenging task that we have chosen to divide into three phases. First, timing was derived from VME based systems. In the second phase, described in this paper, timing pulses are generated by an in house designed PCI timing card installed in ten diagnostics PCs. Using fan-out modules, enough triggers were generated for all instruments. This paper describes how the Timing NAD (Network Attached Device) was rapidly developed using our NAD template, LabVIEW's PCI driver wizard, and LabVIEW Channel Access library. The NAD...

  3. Fielding of the on-axis diagnostic package at Z

    International Nuclear Information System (INIS)

    Hurst, M.J.; Nash, T.J.; Derzon, M.; Kellogg, J.W.; Torres, J.; McGurn, J.; Seaman, J.; Jobe, D.; Lazier, S.E.

    1998-06-01

    The authors have developed a comprehensive diagnostic package for observing z-pinch radiation along the pinch axis on the Z accelerator. The instrumentation, which was fielded on the axial package, are x-ray diagnostics requiring direct lines of sight to the target. The diagnostics require vacuum access to the center of the accelerator. The environment is a hostile one, where one must deal with an intense, energetic photon flux (>100 keV), EMP, debris (e.g. bullets or shrapnel), and mechanical shock in order for the diagnostics to survive. In addition, practical constraints require the package be refurbished and utilized on a once a day shot schedule. In spite of this harsh environment, the authors have successfully fielded the diagnostic package with a high survivability of the data and the instruments. In this paper, they describe the environment and issues related to the re-entrant diagnostic package's implementation and maintenance

  4. Commissioning Instrument for the GTC

    Science.gov (United States)

    Cuevas, S.; Sánchez, B.; Bringas, V.; Espejo, C.; Flores, R.; Chapa, O.; Lara, G.; Chavolla, A.; Anguiano, G.; Arciniega, S.; Dorantes, A.; González, J. L.; Montoya, J. M.; Toral, R.; Hernández, H.; Nava, R.; Devaney, N.; Castro, J.; Cavaller-Marqués, L.

    2005-12-01

    During the GTC integration phase, the Commissioning Instrument (CI) will be a diagnostic tool for performance verification. The CI features four operation modes: imaging, pupil imaging, Curvature WFS, and high resolution Shack-Hartmann WFS. This instrument was built by the Instituto de Astronomía UNAM and the Centro de Ingeniería y Desarrollo Industrial (CIDESI) under GRANTECAN contract after a public bid. In this paper we made a general instrument overview and we show some of the performance final results obtained when the Factory Acceptance tests previous to its transport to La Palma.

  5. Energy and environment at a crossroads - perspectives from the social studies of the SAMRAM research programme

    International Nuclear Information System (INIS)

    Roevik, Arne Oe.

    2001-01-01

    Leading abstract. The research programme SAMRAM was carried out by the Research Council of Norway in 1996-2000. The present book contains twelve articles based on the results of the programme. The articles are grouped in three main sections: (1) The energy markets - environmental effects, innovation and consumption, (2) Energy and environmental policy - international relations and national instruments, (3) Instruments of the energy- and environmental policy - motivation and behaviour

  6. Real-time measurement and control at JET signal processing and physics analysis for diagnostics

    International Nuclear Information System (INIS)

    Felton, R.; Joffrin, E.; Murari, A.

    2005-01-01

    To meet the requirements of the scientific programme, the EFDA JET real-time measurement and control project has developed an integrated set of real-time plasma measurements, experiment control and communication facilities. Traditional experiments collected instrument data during the plasma pulse and calculated physics data after the pulse. The challenge for continuous tokamak operation is to calculate the physics data in real-time, keeping up with the evolution of the plasma. In JET, many plasma diagnostics have been augmented with extra data acquisition and signal-processing systems so that they can both capture instrument data for conventional post-pulse analysis and calculate calibrated, validated physics results in real-time. During the pulse, the systems send sampled data sets into a network, which distributes the data to several destinations. The receiving systems may do further analysis, integrating data from several measurements, or may control the plasma scenario by heating or fuelling. The simplest real-time diagnostic systems apply scale factors to the signals, as with the electron cyclotron emission (ECE) diagnostic's 96 tuned radiometer channels, giving the electron temperature profile. In various spectroscopy diagnostics, spectral features are least-squares-fitted to measure spectra from several lines of sight, within 50 ms. Ion temperatures and rotation speed can be calculated from the line widths and shifts. For diagnostics using modulation techniques, the systems implement digital-signal processing phase trackers, lock-in amplifiers and filters, e.g., the far infrared (FIR) interferometer samples 15 channels at 400 kHz for 30 s, i.e., six million samples per second. Diagnostics have specific lines of sight, spatial channels, and various sampling rates. The heating/fuelling systems have relatively coarse spatial localisation. Analysis systems have been developed to integrate the basic physics data into smaller sets of controllable parameters on a

  7. Fault-tolerant and Diagnostic Methods for Navigation

    DEFF Research Database (Denmark)

    Blanke, Mogens

    2003-01-01

    to diagnose faults and autonomously provide valid navigation data, disregarding any faulty sensor data and use sensor fusion to obtain a best estimate for users. This paper discusses how diagnostic and fault-tolerant methods are applicable in marine systems. An example chosen is sensor fusion for navigation......Precise and reliable navigation is crucial, and for reasons of safety, essential navigation instruments are often duplicated. Hardware redundancy is mostly used to manually switch between instruments should faults occur. In contrast, diagnostic methods are available that can use analytic redundancy...

  8. Optical beam diagnostics on PEP

    International Nuclear Information System (INIS)

    Sabersky, A.P.

    1981-02-01

    In designing the PEP optical diagnostics we have been able to build on the experience gained with SPEAR. Most of the problems at SPEAR could be traced to the optical diagnostic system being inside the tunnel. A machine shutdown is required for any maintenance or modification. This implies that in order to make such an instrument successful, a large engineering effort must be mounted to ensure 100% operation at startup. The functions that do not work at startup may never be made to work; this has happened at several machines. Experimental setups are likewise risky and time consuming. A point which has been borne out in both SPEAR and PEP is that the mechanical part of the instrument, the special vacuum chamber, the optical mounts, the alignment and adjustments, require approximately 60% of the effort and cost of the optical diagnostics. It is far better to economize on detectors and electronics than on mechanical and optical essentials

  9. Characteristics of the IAEA correlation monitor material for surveillance programmes

    International Nuclear Information System (INIS)

    Wallin, K.; Valo, M.; Rintamaa, R.; Toerroenen, K.

    1989-08-01

    Within the IAEA Coordinated Research Programme on optimizing of reactor pressure vessel surveillance programmes and their analysis, phase 3, a specially tailored 'radiation sensitive' correlation monitor material has been fabricated. This material will serve as a reference to the IAEA programme for future vessel surveillance programmes throughout the world. An extensive evaluation of the correlation monitor material in the as-received condition has been carried out in Finland and the results are presented here. The mechanical properties measured at different temperatures include Charpy V notch and instrumented precracked Charpy data, and elastic-plastic fracture toughness (J). The specimen size and geometry have been varied in the tests. Correlation between different fracture properties are evaluated and discussed

  10. Microfluidic diagnostics for low-resource settings

    Science.gov (United States)

    Hawkins, Kenneth R.; Weigl, Bernhard H.

    2010-02-01

    Diagnostics for low-resource settings need to be foremost inexpensive, but also accurate, reliable, rugged and suited to the contexts of the developing world. Diagnostics for global health, based on minimally-instrumented, microfluidicsbased platforms employing low-cost disposables, has become a very active research area recently-thanks, in part, to new funding from the Bill & Melinda Gates Foundation, the National Institutes of Health, and other sources. This has led to a number of interesting prototype devices that are now in advanced development or clinical validation. These devices include disposables and instruments that perform multiplexed PCR-based assays for enteric, febrile, and vaginal diseases, as well as immunoassays for diseases such as malaria, HIV, and various sexually transmitted diseases. More recently, instrument-free diagnostic disposables based on isothermal nucleic-acid amplification have been developed. Regardless of platform, however, the search for truly low-cost manufacturing methods that would enable affordable systems (at volume, in the appropriate context) remains a significant challenge. Here we give an overview of existing platform development efforts, present some original research in this area at PATH, and reiterate a call to action for more.

  11. Prospective study of factors influencing conditional discharge from a forensic hospital: the DUNDRUM-3 programme completion and DUNDRUM-4 recovery structured professional judgement instruments and risk.

    LENUS (Irish Health Repository)

    Davoren, Mary

    2013-01-01

    We set out to examine whether structured professional judgement instruments DUNDRUM-3 programme completion (D-3) and DUNDRUM-4 recovery (D-4) scales along with measures of risk, mental state and global function could distinguish between those forensic patients detained in a secure forensic hospital (not guilty by reason of insanity or unfit to stand trial) who were subsequently discharged by a mental health review board. We also examined the interaction between these measures and risk, need for therapeutic security and eventual conditional discharge.

  12. Failure mode taxonomy for assessing the reliability of Field Programmable Gate Array based Instrumentation and Control systems

    International Nuclear Information System (INIS)

    McNelles, Phillip; Zeng, Zhao Chang; Renganathan, Guna; Chirila, Marius; Lu, Lixuan

    2017-01-01

    Highlights: • The use FPGAs in I&C systems in Nuclear Power Plants is an important issue (IAEA). • OECD-NEA published a failure mode taxonomy for software-based digital I&C systems. • This paper extends the OECD-NEA taxonomy to model FPGA-based systems. • FPGA failure modes, failure effects, uncovering methods are categorized/described. • Provides an example of modelling an FPGA-Based RTS/ESFAS using the FPGA taxonomy. - Abstract: Field Programmable Gate Arrays (FPGAs) are a form of programmable digital hardware configured to perform digital logic functions. This configuration (programming) is performed using Hardware Description Language (HDL), making FPGAs a form of HDL Programmed Device (HPD). In the nuclear field, FPGAs have seen use in upgrades and replacements of obsolete Instrumentation and Control (I&C) systems. This paper expands upon previous work that resulted in extensive FPGA failure mode data, to allow for the application of the OECD-NEA failure modes taxonomy. The OECD-NEA taxonomy presented a method to model digital (software-based) I&C systems, based on the hardware and software failure modes, failure uncovering effects and levels of abstraction, using a Reactor Trip System/Engineering Safety Feature Actuation System (RTS/ESFAS) as an example system. To create the FPGA taxonomy, this paper presents an additional “sub-component” level of abstraction, to demonstrate the effect of the FPGA failure modes and failure categories on an FPGA-based system. The proposed FPGA taxonomy is based on the FPGA failure modes, failure categories, failure effects and uncovering situations. The FPGA taxonomy is applied to the RTS/ESFAS test system, to demonstrate the effects of the anticipated FPGA failure modes on a digital I&C system, and to provide a modelling example for this proposed taxonomy.

  13. Diagnostic work-up and loss of tuberculosis suspects in Jogjakarta, Indonesia.

    Science.gov (United States)

    Ahmad, Riris Andono; Matthys, Francine; Dwihardiani, Bintari; Rintiswati, Ning; de Vlas, Sake J; Mahendradhata, Yodi; van der Stuyft, Patrick

    2012-02-15

    Early and accurate diagnosis of pulmonary tuberculosis (TB) is critical for successful TB control. To assist in the diagnosis of smear-negative pulmonary TB, the World Health Organisation (WHO) recommends the use of a diagnostic algorithm. Our study evaluated the implementation of the national tuberculosis programme's diagnostic algorithm in routine health care settings in Jogjakarta, Indonesia. The diagnostic algorithm is based on the WHO TB diagnostic algorithm, which had already been implemented in the health facilities. We prospectively documented the diagnostic work-up of all new tuberculosis suspects until a diagnosis was reached. We used clinical audit forms to record each step chronologically. Data on the patient's gender, age, symptoms, examinations (types, dates, and results), and final diagnosis were collected. Information was recorded for 754 TB suspects; 43.5% of whom were lost during the diagnostic work-up in health centres, 0% in lung clinics. Among the TB suspects who completed diagnostic work-ups, 51.1% and 100.0% were diagnosed without following the national TB diagnostic algorithm in health centres and lung clinics, respectively. However, the work-up in the health centres and lung clinics generally conformed to international standards for tuberculosis care (ISTC). Diagnostic delays were significantly longer in health centres compared to lung clinics. The high rate of patients lost in health centres needs to be addressed through the implementation of TB suspect tracing and better programme supervision. The national TB algorithm needs to be revised and differentiated according to the level of care.

  14. Programmes of measures under the water framework directive – a comparative case study

    DEFF Research Database (Denmark)

    Baaner, Lasse

    2011-01-01

    The water framework directive requires programmes of measures composed by the Member States, in order to achieve its environmental objectives. This article examines three programmes of measures for river basins in Denmark, Sweden, and Norway, with a focus on the differences in how the programmes...... direct the authorities’ activities with regard to water management. It concludes that there are major differences in the precision of the measures, the range of legal instruments used, and in the focus on active and direct management of the aquatic environment. The Danish programme seems to facilitate...

  15. Interfacing to accelerator instrumentation

    International Nuclear Information System (INIS)

    Shea, T.J.

    1995-01-01

    As the sensory system for an accelerator, the beam instrumentation provides a tremendous amount of diagnostic information. Access to this information can vary from periodic spot checks by operators to high bandwidth data acquisition during studies. In this paper, example applications will illustrate the requirements on interfaces between the control system and the instrumentation hardware. A survey of the major accelerator facilities will identify the most popular interface standards. The impact of developments such as isochronous protocols and embedded digital signal processing will also be discussed

  16. Development of national immunoassay reagent programmes

    International Nuclear Information System (INIS)

    Sufi, S.B.; Micallef, J.V.; Ahsan, R.; Goncharov, N.P.

    1992-01-01

    Despite the existence of networks of fully equipped laboratories with well-trained staff, the availability of immunodiagnostic services in developing countries is often limited by the high cost of imported kits. There are a number of ways of tackling this problem, ranging from bulk purchase of kits or reagents to local development and production of assay systems. Argentina/Chile, China, Cuba/Mexico, and Thailand are amongst the countries which have established local immunoassay reagent programmes to manufacture low cost, high quality immunoassay reagents. Kits from these projects are now beginning to become available, and it is hoped that they will promote national diagnostic services and research, as well as stimulating the development of reagent programmes for other analytes. (author). 4 refs, 1 tab

  17. Performance and quality control of nuclear medicine instrumentation

    International Nuclear Information System (INIS)

    Paras, P.

    1981-01-01

    The status and the recent developments of nuclear medicine instrumentation performance, with an emphasis on gamma-camera performance, are discussed as the basis for quality control. New phantoms and techniques for the measurement of gamma-camera performance parameters are introduced and their usefulness for quality control is discussed. Tests and procedures for dose calibrator quality control are included. Also, the principles of quality control, tests, equipment and procedures for each type of instrument are reviewed, and minimum requirements for an effective quality assurance programme for nuclear medicine instrumentation are suggested. (author)

  18. Multimode laser beam analyzer instrument using electrically programmable optics.

    Science.gov (United States)

    Marraccini, Philip J; Riza, Nabeel A

    2011-12-01

    Presented is a novel design of a multimode laser beam analyzer using a digital micromirror device (DMD) and an electronically controlled variable focus lens (ECVFL) that serve as the digital and analog agile optics, respectively. The proposed analyzer is a broadband laser characterization instrument that uses the agile optics to smartly direct light to the required point photodetectors to enable beam measurements of minimum beam waist size, minimum waist location, divergence, and the beam propagation parameter M(2). Experimental results successfully demonstrate these measurements for a 500 mW multimode test laser beam with a wavelength of 532 nm. The minimum beam waist, divergence, and M(2) experimental results for the test laser are found to be 257.61 μm, 2.103 mrad, 1.600 and 326.67 μm, 2.682 mrad, 2.587 for the vertical and horizontal directions, respectively. These measurements are compared to a traditional scan method and the results of the beam waist are found to be within error tolerance of the demonstrated instrument.

  19. Diagnostic Criteria for Temporomandibular Disorders (DC/TMD) for Clinical and Research Applications

    DEFF Research Database (Denmark)

    Schiffman, Eric; Ohrbach, Richard; Truelove, Edmond

    2014-01-01

    AIMS: The original Research Diagnostic Criteria for Temporomandibular Disorders (RDC/TMD) Axis I diagnostic algorithms have been demonstrated to be reliable. However, the Validation Project determined that the RDC/TMD Axis I validity was below the target sensitivity of ≥ 0.70 and specificity of ≥...... comprehensive instruments augment short and simple screening instruments for Axis I and Axis II. These validated instruments allow for identification of patients with a range of simple to complex TMD presentations....

  20. Development and Application of a Novel Rasch-Based Methodology for Evaluating Multi-Tiered Assessment Instruments: Validation and Utilization of an Undergraduate Diagnostic Test of the Water Cycle

    Science.gov (United States)

    Romine, William L.; Schaffer, Dane L.; Barrow, Lloyd

    2015-01-01

    We describe the development and validation of a three-tiered diagnostic test of the water cycle (DTWC) and use it to evaluate the impact of prior learning experiences on undergraduates' misconceptions. While most approaches to instrument validation take a positivist perspective using singular criteria such as reliability and fit with a measurement…

  1. Overview of radiation protection programme in nuclear medicine facility for diagnostic procedures

    International Nuclear Information System (INIS)

    Ahmed, Ezzeldein Mohammed Nour Mohammed

    2015-02-01

    This project was conducted to review Radiation Protection Program in Nuclear Medicine facility for diagnostic procedures which will provide guide for meeting the standard and regulatory requirements in diagnostic nuclear medicine. The main objective of this project is to keep dose to staff, patient and public as low as reasonably achievable (ALARA). The specific objectives were to review the Radiation Protection Program (RPP) in diagnostic nuclear medicine and to make some recommendation for improving the level of radiation protection in diagnostic nuclear medicine that will help to control normal exposure and prevent or mitigate potential exposure. The methodology used is review of various documents. The review showed that if the Radiation Protection Program is inadequate it leads to unjustified exposure to radiation. Finally, this study stated some recommendations that if implemented could improve the level of radiation protection in nuclear medicine department. One of the most important recommendations is that a qualified Radiation Protection Officer (RPO) should be appointed to lay down and oversee a radiation protection in the nuclear medicine department. The RPO must be given the full authority and the adequate time to enable him to perform his duties effectively. (au)

  2. 21 CFR 886.1360 - Visual field laser instrument.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Visual field laser instrument. 886.1360 Section 886.1360 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES OPHTHALMIC DEVICES Diagnostic Devices § 886.1360 Visual field laser instrument...

  3. Nova diagnostics summary

    International Nuclear Information System (INIS)

    Slivinsky, V.W.; Drake, R.P.

    1985-01-01

    The authors intend that Nova be the best diagnosed ICF research facility in operation today. The authors experience in providing advanced diagnostics for previous laser systems will be extended at Nova, and will be challenged by the development of new instrumentation to diagnose the more advanced targets made possible by this powerful laser. Previous experience has shown that to understand target performance, the authors must have as complete a set of diagnostics as possible. The Nova diagnostics are divided into two sets: the basic set required for the initial Nova experiments and the more advanced set for later, generally more complex, experiments. The basic set will be operational for the first Nova shots; it was a Nova line item funded with Nova construction money. This basic set is presented in a table

  4. Diagnostic work-up and loss of tuberculosis suspects in Jogjakarta, Indonesia

    Directory of Open Access Journals (Sweden)

    Ahmad Riris

    2012-02-01

    Full Text Available Abstract Background Early and accurate diagnosis of pulmonary tuberculosis (TB is critical for successful TB control. To assist in the diagnosis of smear-negative pulmonary TB, the World Health Organisation (WHO recommends the use of a diagnostic algorithm. Our study evaluated the implementation of the national tuberculosis programme's diagnostic algorithm in routine health care settings in Jogjakarta, Indonesia. The diagnostic algorithm is based on the WHO TB diagnostic algorithm, which had already been implemented in the health facilities. Methods We prospectively documented the diagnostic work-up of all new tuberculosis suspects until a diagnosis was reached. We used clinical audit forms to record each step chronologically. Data on the patient's gender, age, symptoms, examinations (types, dates, and results, and final diagnosis were collected. Results Information was recorded for 754 TB suspects; 43.5% of whom were lost during the diagnostic work-up in health centres, 0% in lung clinics. Among the TB suspects who completed diagnostic work-ups, 51.1% and 100.0% were diagnosed without following the national TB diagnostic algorithm in health centres and lung clinics, respectively. However, the work-up in the health centres and lung clinics generally conformed to international standards for tuberculosis care (ISTC. Diagnostic delays were significantly longer in health centres compared to lung clinics. Conclusions The high rate of patients lost in health centres needs to be addressed through the implementation of TB suspect tracing and better programme supervision. The national TB algorithm needs to be revised and differentiated according to the level of care.

  5. Diagnostic development and support of MHD (magnetohydrodynamics) test facilities

    Energy Technology Data Exchange (ETDEWEB)

    1989-07-01

    Mississippi State University (MSU) is developing diagnostic instruments for Magnetohydrodynamics (MHD) power train data acquisition and for support of MHD component development test facilities. Microprocessor-controlled optical instruments, initially developed for HRSR support, are being refined, and new systems to measure temperatures and gas-seed-slag stream characteristics are being developed. To further data acquisition and analysis capabilities, the diagnostic systems are being interfaced with MHD Energy Center computers. Technical support for the diagnostic needs of the national MHD research effort is being provided. MSU personnel will also cooperate with government agencies and private industries to improve the transformation of research and development results into processes, products and services applicable to their needs.

  6. Proceedings of the advanced research and technology development direct utilization, instrumentation and diagnostics contractors' review meeting

    Energy Technology Data Exchange (ETDEWEB)

    Geiling, D.W. (USDOE Morgantown Energy Technology Center, WV (USA)); Goldberg, P.M. (eds.) (USDOE Pittsburgh Energy Technology Center, PA (USA))

    1990-01-01

    The 1990 Advanced Research and Technology Development (AR TD) Direct Utilization, and Instrumentation and Diagnostics Contractors Review Meeting was held September 16--18, 1990, at the Hyatt at Chatham Center in Pittsburgh, PA. The meeting was sponsored by the US Department of Energy (DOE), Office of Fossil Energy, and the Pittsburgh and Morgantown Energy Technology Centers. Each year the meeting provides a forum for the exchange of information among the DOE AR TD contractors and interested parties. This year's meeting was hosted by the Pittsburgh Energy Technology Center and was attended by 120 individuals from industry, academia, national laboratories, and other governmental agencies. Papers were presented on research addressing coal surface, science, devolatilization and combustion, ash behavior, emission controls for gases particulates, fluid bed combustion and utilization in diesels and turbines. Individual reports are processed separately for the data bases.

  7. Decentralized computerized process control system (CPCS) of the Kozloduy NPP water treatment unit based on programmable automata

    Energy Technology Data Exchange (ETDEWEB)

    Shervashidze, N; Slavov, S; Hristakudis, N; Terziev, V [Energoproekt, Sofia (Bulgaria)

    1987-01-01

    The system performs the following control functions: program management of discrete processes (in mechanical and ion filters); direct digital maintenance of continuous processes; data acquisition, processing, displaying and printing of the control data; internal system functions as operator error protection, control equipment diagnostics, devices fault protection and signalling, etc. The system is based on six basic programmable automata (BPA), four of them control various functional groups of instruments and processes, one is a supervisor and one provides the interconnection with the mainframe. Based on the experience gained, the authors pointed out the major advantages, some drawbacks and associated problems of designing and implementation of the distributed decentralized CPCS as a whole. Special attention is paid to the problem of distribution between the functions of the conventional and microprocessor part of CPCS. 1 fig, 2 tabs, 2 refs.

  8. Physics measurements on WWER-440 diagnostic assemblies

    International Nuclear Information System (INIS)

    Dach, K.; Jirousek, V.; Kott, J.; Horak, J.; Teren, S.; Nemec, J.

    1980-01-01

    The aims of physics measurements using diagnostic assemblies are the development of neutron noise diagnostics methods, the improvement of knowledge of the physical properties of the WWER reactor cores, the testing of computer programs, and the specification of nuclear safety criteria and the obtaining of information allowing the optimum nuclear fuel economy. The instrumentation of diagnostic assemblies is briefly described, including miniature fission chambers, SPN detectors and calorimeters. The method of evaluating and experimental testing is shown. (M.S.)

  9. Tevatron instrumentation: boosting collider performance

    Energy Technology Data Exchange (ETDEWEB)

    Shiltsev, Vladimir; Jansson, Andreas; Moore, Ronald; /Fermilab

    2006-05-01

    The Tevatron in Collider Run II (2001-present) is operating with six times more bunches, many times higher beam intensities and luminosities than in Run I (1992-1995). Beam diagnostics were crucial for the machine start-up and the never-ending luminosity upgrade campaign. We present the overall picture of the Tevatron diagnostics development for Run II, outline machine needs for new instrumentation, present several notable examples that led to Tevatron performance improvements, and discuss the lessons for the next big machines--LHC and ILC.

  10. Development and implantation of a control and data acquisition program for the calibration of instruments for diagnostic radiology

    International Nuclear Information System (INIS)

    Betti, Flavio

    2007-01-01

    Design techniques of an automatic control system implementing corrected kerma determination and shutter command in the calibration laboratory at IPEN are shown, as well as the periodic calibration program developed for a monitor chamber for several X-ray beam qualities used for diagnostic radiology and radiation protection instruments. Two reference electrometers, a multichannel secondary standard thermometer, and an absolute pressure barometer were connected to the Rs-232 interface from a PC computer equipped with a National Instruments multi function analog and digital I/O card. LabVIEW MR was chosen as programming tool, which allowed for the development of a suite of programs for both controlling the shutter timing cycles and the calibration of the monitor chamber against a reference standard. A detailed description of the methods used for troubleshooting, fine tuning of parameters and evaluation of program results is followed by an analysis showing that considerable advantages regarding reduction of time and precision improvements during the calibrations could be achieved by the use of the developed programs, particularly under adverse conditions like those found during short expositions, or instead during long irradiation intervals where fluctuation of parameters like kerma rate or room conditions (temperature or pressure) can be found. (author)

  11. Research and realization of signal simulation on virtual instrument

    Science.gov (United States)

    Zhao, Qi; He, Wenting; Guan, Xiumei

    2010-02-01

    In the engineering project, arbitrary waveform generator controlled by software interface is needed by simulation and test. This article discussed the program using the SCPI (Standard Commands For Programmable Instruments) protocol and the VISA (Virtual Instrument System Architecture) library to control the Agilent signal generator (Agilent N5182A) by instrument communication over the LAN interface. The program can conduct several signal generations such as CW (continuous wave), AM (amplitude modulation), FM (frequency modulation), ΦM (phase modulation), Sweep. As the result, the program system has good operability and portability.

  12. Management of the camera electronics programme for the World Space Observatory ultraviolet WUVS instrument

    Science.gov (United States)

    Patel, Gayatri; Clapp, Matthew; Salter, Mike; Waltham, Nick; Beardsley, Sarah

    2016-08-01

    World Space Observatory Ultraviolet (WSO-UV) is a major international collaboration led by Russia and will study the universe at ultraviolet wavelengths between 115 nm and 320 nm. The WSO Ultraviolet Spectrograph (WUVS) subsystem is led by a consortium of Russian institutes and consists of three spectrographs. RAL Space is contracted by e2v technologies Ltd to provide the CCD readout electronics for each of the three WUVS channels. The programme involves the design, manufacturing, assembly and testing of each Camera Electronics Box (CEB), its associated Interconnection Module (ICM), Electrical Ground Support Equipment (EGSE) and harness. An overview of the programme will be presented, from the initial design phase culminating in the development of an Engineering Model (EM) through qualification whereby an Engineering Qualification Model (EQM) will undergo environmental testing to characterize the performance of the CEB against the space environment, to the delivery of the Flight Models (FMs). The paper will discuss the challenges faced managing a large, dynamic project. This includes managing significant changes in fundamental requirements mid-programme as a result of external political issues which forced a complete re-design of an existing CEB with extensive space heritage but containing many ITAR controlled electronic components to a new, more efficient solution, free of ITAR controlled parts. The methodology and processes used to ensure the demanding schedule is maintained through each stage of the project will be presented including an insight into planning, decision-making, communication, risk management, and resource management; all essential to the continued success of the programme.

  13. Automation, consolidation, and integration in autoimmune diagnostics.

    Science.gov (United States)

    Tozzoli, Renato; D'Aurizio, Federica; Villalta, Danilo; Bizzaro, Nicola

    2015-08-01

    Over the past two decades, we have witnessed an extraordinary change in autoimmune diagnostics, characterized by the progressive evolution of analytical technologies, the availability of new tests, and the explosive growth of molecular biology and proteomics. Aside from these huge improvements, organizational changes have also occurred which brought about a more modern vision of the autoimmune laboratory. The introduction of automation (for harmonization of testing, reduction of human error, reduction of handling steps, increase of productivity, decrease of turnaround time, improvement of safety), consolidation (combining different analytical technologies or strategies on one instrument or on one group of connected instruments) and integration (linking analytical instruments or group of instruments with pre- and post-analytical devices) opened a new era in immunodiagnostics. In this article, we review the most important changes that have occurred in autoimmune diagnostics and present some models related to the introduction of automation in the autoimmunology laboratory, such as automated indirect immunofluorescence and changes in the two-step strategy for detection of autoantibodies; automated monoplex immunoassays and reduction of turnaround time; and automated multiplex immunoassays for autoantibody profiling.

  14. Reactor instrumentation experience at IPEN-CNEN/SP

    International Nuclear Information System (INIS)

    Soares, A.J.

    1997-01-01

    The Instituto de Pesquisas Energeticas e Nucleares (IPEN) in Sao Paulo started in 1977 development of nuclear instrumentation. In 1982 two groups were established, one responsible for maintenance of electronic equipment and the other, the Nuclear Instrumentation Section (NIS), for new projects, such as a light water moderated critical facility (IPEN/MB-0). The NIS had the responsibility to execute all necessary activities to develop the ''nonconventional'' instrumentation systems: control, protection and radiation monitoring for the IPEN/MB-01 facility. After the commissioning of the critical facility the NIS group started the development of instrumentation systems for a power reactor. As a first step an overall review of the quality assurance programme was implemented. In parallel the development of self powered detectors was carried out. (author). 7 figs

  15. Thioaptamer Diagnostic System (TDS)

    Science.gov (United States)

    Yang, Xianbin

    2015-01-01

    AM Biotechnologies, LLC, in partnership with Sandia National Laboratories, has developed a diagnostic device that quickly detects sampled biomarkers. The TDS quickly quantifies clinically relevant biomarkers using only microliters of a single sample. The system combines ambient-stable, long shelf-life affinity assays with handheld, microfluidic gel electrophoresis affinity assay quantification technology. The TDS is easy to use, operates in microgravity, and permits simultaneous quantification of 32 biomarkers. In Phase I of the project, the partners demonstrated that a thioaptamer assay used in the microfluidic instrument could quantify a specific biomarker in serum in the low nanomolar range. The team also identified novel affinity agents to bone-specific alkaline phosphatase (BAP) and demonstrated their ability to detect BAP with the microfluidic instrument. In Phase II, AM Biotech expanded the number of ambient affinity agents and demonstrated a TDS prototype. In the long term, the clinical version of the TDS will provide a robust, flight-tested diagnostic capability for space exploration missions.

  16. Presentation of a new instrument

    DEFF Research Database (Denmark)

    Russell, M B; Rasmussen, B K; Brennum, J

    1992-01-01

    A new instrument, the Diagnostic Headache Diary, based on the operational diagnostic criteria of the International Headache Society (IHS), was tested in 61 migraine patients from a headache research clinic using the clinical diagnosis (IHS criteria) for comparison. All patients kept the diary...... for one to eight months. The clinical and diary diagnosis of migraine with and without aura was the same in, respectively, 72 and 87% of the patients. Nausea, photophobia and phonophobia tended to be more pronounced at the clinical interview. The diary identified 20 more cases of episodic tension......-type headache and 15 fewer cases of chronic tension-type headache than the clinical interview. Two blinded observers always made the same IHS diagnoses when interpreting the diagnostic headache diary. A combination of a clinical interview and the diagnostic headache diary gives a qualitatively...

  17. Quality assurance of medical education in the Netherlands: programme or systems accreditation?

    Science.gov (United States)

    Hillen, Harry F P

    2010-01-01

    Accreditation is an instrument that is used worldwide to monitor, maintain and improve the quality of medical education. International standards have been defined to be used in reviewing and evaluating the quality of education. The organization and the process of accreditation of medical education programmes in the Netherlands and in Flanders are described in some detail. Accreditation can be based on the results of a detailed assessment of an educational programme or on an evaluation of the educational system and the organization of the institution in question. The Flemish-Dutch accreditation organization (NAO) is moving from programme accreditation towards a combination of programme and systems accreditation. The pros and cons of these two approaches are discussed.

  18. Diagnostics aid for mass spectrometer trouble-shooting

    International Nuclear Information System (INIS)

    Filby, E.E.; Rankin, R.A.; Webb, G.W.

    1987-01-01

    The ''MS Expert'' system provides problem diagnostics for instruments used in the Mass Spectrometry Laboratory (MSL). The most critical results generated on these mass spectrometers are the uranium concentration and isotopic content data used for process control and materials accountability at the Idaho Chemical Processing Plant. The two purposes of the system are: (1) to minimize instrument downtime and thereby provide the best possible support to the Plant, and (2) to improve long-term data quality. This system combines the knowledge of several experts on mass spectrometry to provide a diagnostic tool, and can make these skills avilable on a more timely basis. It integrates code written in the Pascal language with a knowledge base entered into a commercial expert system ''shell.'' The user performs some preliminary status checks, and then selects from among several broad diagnostic categories. These initial steps provide input to the rule base. The overall analysis provides the user with a set of possible solutions to the observed problems, graded as to their probabilities. Besides the trouble-shooting benefits expected from this system, it will also provide structures diagnostic training for lab personnel. In addition, development of the system knowledge base has already produced a better understanding of instrument behavior. Two key findings are that a good user interface is necessary for full acceptance of the tool, and a development system should include standard programming capabilities as well as the expert system shell. 22 refs., 5 figs

  19. Diagnostics aid for mass spectrometer trouble-shooting

    International Nuclear Information System (INIS)

    Filby, E.E.; Rankin, R.A.; Webb, G.W.

    1987-01-01

    The MS Expert system provides problem diagnostics for instruments used in the Mass Spectrometry Laboratory (MSL). The most critical results generated on these mass spectrometers are the uranium concentration and isotopic content data used for process control and materials accountability at the Idaho General Processing Plant. The two purposes of the system are: (1) to minimize instrument downtime and thereby provide the best possible support to the Plant, and (2) to improve long-term data quality. This system combines the knowledge of several experts on mass spectrometry to provide a diagnostic tool, and can make these skills available on a more timely basis. It integrates code written in the Pascal language with a knowledge base entered into a commercial expert system shell. The user performs some preliminary status checks, and then selects from among several broad diagnostic categories. These initial steps provide input to the rule base. The overall analysis provides the user with a set of possible solutions to the observed problems, graded as to their probabilities. Besides the trouble-shooting benefits expected from this system, it also provides structured diagnostic training for lab personnel. In addition, development of the system knowledge base has already produced a better understanding of instrument behavior. Two key findings are that a good user interface is necessary for full acceptance of the tool, and, a development system should include standard programming capabilities as well as the expert system shell

  20. Microprocessor-controlled data-acquisition instrument for neutron-activation measurements

    International Nuclear Information System (INIS)

    Jones, B.A.

    1981-01-01

    This paper describes a microprocessor controlled data acquisition instrument designed at Lawrence Livermore National Laboratory to provide experimenters with a diagnostic tool for measuring the performance of laser imploded fusion targets via neutron activation techniques. This instrument features the ability to count four independent inputs simultaneously while providing a front panel readout of these inputs, plus a time of day clock. A hardcopy printout of the data is also provided by a built-in thermal printer. All running modes and parameters are user selectable via a front panel keypad, and a complete set of internal self-testing diagnostics are available for debug

  1. MTX [Microwave Tokamak Experiment] plasma diagnostic system

    International Nuclear Information System (INIS)

    Rice, B.W.; Hooper, E.B.; Brooksby, C.A.

    1987-01-01

    In this paper, a general overview of the MTX plasma diagnostics system is given. This includes a description of the MTX machine configuration and the overall facility layout. The data acquisition system and techniques for diagnostic signal transmission are also discussed. In addition, the diagnostic instruments planned for both an initial ohmic-heating set and a second FEL-heating set are described. The expected range of plasma parameters along with the planned plasma measurements will be reviewed. 7 refs., 5 figs

  2. Galileo Avionica's technologies and instruments for planetary exploration.

    Science.gov (United States)

    Battistelli, E; Falciani, P; Magnani, P; Midollini, B; Preti, G; Re, E

    2006-12-01

    Several missions for planetary exploration, including comets and asteroids, are ongoing or planned by the European Space Agencies: Rosetta, Venus Express, Bepi Colombo, Dawn, Aurora and all Mars Programme (in its past and next missions) are good examples. The satisfaction of the scientific request for the mentioned programmes calls for the development of new instruments and facilities devoted to investigate the body (planet, asteroid or comet) both remotely and by in situ measurements. The paper is an overview of some instruments for remote sensing and in situ planetary exploration already developed or under study by Galileo Avionica Space & Electro-Optics B.U. (in the following shortened as Galileo Avionica) for both the Italian Space Agency (ASI) and for the European Space Agency (ESA). Main technologies and specifications are outlined; for more detailed information please refer to Galileo Avionica's web-site at: http://www.galileoavionica.com .

  3. General and preliminary thermohydraulic, hydrogen and aerosol instrumentation plan for the Phebus Fp-project

    International Nuclear Information System (INIS)

    Hampel, G.; Poss, G.; Frohlich, H.K.

    1989-10-01

    The objective of the project was to draw up an instrumentation plan for the French core melting programme PHEBUS FP. This instrumentation plan essentially was to include proven and reliable instruments for recording various thermohydraulic, aerosol and hydrogen phenomena. The candidate measuring methods, which are known mainly from reactor safety programmes, have been described and examined for their usefulness in PHEBUS. Each method and instrument has been described in detail under various aspects such as measuring principle, measuring range, technical design, evaluation model, calibration procedure, accuracy, previous experience, commercial availability, etc. Special attention has been paid to the behaviour of the measuring transducers when exposed to radiation. First, the performance of the instruments was compared with the requirements of PHEBUS. The results of this comparison served as the basis for a measuring concept in tabular form, giving the locations of the measurements, the measuring tasks, and the number and kind of instruments that are recommended. Redundancy and cost-benefit aspects have been taken into account in qualitative terms

  4. Spectroscopic diagnostics and measurements at Jet

    International Nuclear Information System (INIS)

    Giannella, R.

    1994-01-01

    A concise review is presented of activity in the field spectroscopic diagnostic at JET during the latest few years. Together with a description of instruments, examples are given of the measurements conducted with these systems and some experimental result obtained with such activity are outlined. Emphasis is also given to the upgrading of existing apparatuses and the construction of new diagnostics ahead of the next experimental phase. 48 refs., 5 figs

  5. The WHO AFRO external quality assessment programme (EQAP): Linking laboratory networks through EQA programmes.

    Science.gov (United States)

    Boeras, Debrah I; Peeling, Rosanna W; Onyebujoh, Philip; Yahaya, Ali A; Gumede-Moeletsi, Hieronyma N; Ndihokubwayo, Jean B

    2016-01-01

    External Quality Assessment (EQA) surveys performed by the World Health Organization Regional Office for Africa (WHO AFRO) revealed the need for the strengthening of public health microbiology laboratories, particularly for testing of epidemic-prone diseases in the African Region. These surveys revealed common issues such as supply chain management, skilled personnel, logistical support and overall lack of quality standards. For sustainable improvements to health systems as well as global health security, deficiencies identified need to be actively corrected through robust quality assurance programmes and implementation of laboratory quality management systems. Given all the pathogens of public health importance, an external quality assessment programme with a focus on vaccine-preventable diseases and emerging and re-emerging dangerous pathogens is important, and should not be stand-alone, but integrated within laboratory networks as seen in polio, measles, yellow fever and rubella. In 2015, WHO AFRO collaborated with the US Centers for Disease Control and Prevention, the London School of Hygiene & Tropical Medicine and partners in a series of consultations with countries and national and regional EQA providers for the development of quality assurance models to support HIV point-of-care testing and monitoring. These consultations revealed similar challenges as seen in the WHO AFRO surveys. WHO AFRO brought forth its experience in implementing quality standards for health programmes, and also opened discussions on how lessons learned through such established programmes can be utilised to supporting and strengthening the introduction of early infant diagnosis of HIV and viral load point-of-care testing. An optimised external quality assessment programme will impact the ability of countries to meet core capacities, providing improved quality management systems, improving the confidence of diagnostic network services in Africa, and including capacities to detect events

  6. Policy Pathways: Energy Management Programmes for Industry

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2012-09-06

    The IEA Policy Pathway publications provide details on how to implement specific recommendations drawn from the IEA 25 Energy Efficiency Policy Recommendations. This Policy Pathway, jointly produced by the International Energy Agency and the Institute for Industrial Productivity, develops the critical steps for policy makers implementing energy management programmes for industry. Optimising energy use in industry is essential to improve industrial competitiveness and achieve wider societal goals such as energy security, economic recovery and development, climate change mitigation and environmental protection.While there is significant potential to decrease energy consumption in this sector, opportunities to improve energy efficiency are still under-exploited. Energy management programmes have shown to be instrumental in addressing many of the barriers that inhibit wide-scale uptake of energy management in industry. The Policy Pathway builds on lessons learned from country experiences and provides actionable guidance on how to plan and design, implement, evaluate and monitor energy management programmes for industry.

  7. Initial results from the newborn hearing screening programme in Ireland.

    LENUS (Irish Health Repository)

    O'Connor, A

    2013-03-02

    INTRODUCTION: Hearing screening programmes aim to detect hearing loss in the neonate. The Health Service Executive (HSE) South was the first phase of a national roll-out of a neonatal hearing screening programme in Ireland, going live on 28 April 2011. RESULTS: Over 11,738 babies have been screened for permanent childhood hearing impairment (PCHI) during the first 12 months. The percentage of eligible babies offered hearing screening was 99.2 %. Only 0.2 % (n = 25) of those offered screening declined. 493 (4 %) were referred for immediate diagnostic audiological assessment. The average time between screen and diagnostic audiology appointment was 2 weeks. 15 (1.3\\/1,000) babies have been identified with a PCHI over the 12-month period. 946 (4 %) babies screened were admitted to the neonatal intensive care unit (NICU) for >48 h. The prevalance of PCHI is 7.3\\/1,000 in the NICU population compared to 0.6\\/1000 in the well baby population. 214 (1.8 % of total babies screened) had a clear response in the screening programmes, but were deemed to be at risk of an acquired childhood hearing impairment. These babies will be reassessed with a diagnostic audiology appointment at 8-9 months of age. To date, there is one case of acquired hearing impairment through this targeted follow-up screen. Of the 15 cases of PCHI identified, 8 (53 %) of these had one or more risk factors for hearing loss and 7 (37 %) were admitted to the NICU for >48 h. Four babies were referred for assessment at the National Cochlear Implant Centre.

  8. High-Throughput Array Instrument for DNA-Based Breast Cancer Diagnostics

    National Research Council Canada - National Science Library

    Swerdlow, Harold

    2000-01-01

    ...) for breast-cancer diagnostics. These methods are based upon large numbers of discrete DNA spots placed on glass microscope slides typically, and hybridized to a probe derived from a tIssue or blood sample...

  9. Detailed Performance Assessment for the ITER ECE Diagnostic

    Science.gov (United States)

    Rowan, W.; Austin, M.; Houshmandyar, S.; Phillips, P.; Beno, J.; Bryant, A.; Ouroua, A.; Weeks, D.; Hubbard, A.; Taylor, G.

    2017-10-01

    One of the primary diagnostics for electron temperature (Te) measurement on ITER is based on the detection of electron cyclotron emission (ECE) Here we describe the predicted performance of the newly completed ECE diagnostic design by quantitatively following the emission from the plasma to the instruments and including the calibration method to assess accuracy. Operation of the diagnostic at 5.3 T is the main interest here but critical features of the emission spectra for 2.65 T and 1.8 T will be described. ECE will be collected by two very similar optical systems: one a radial view, the other an oblique view. Both measurements are used for Te while the oblique view also allows detection of non-thermal distortion in the electron distribution. An in-vacuum calibration source is included in the front end of each view to calibrate out the effect of any degradation of in-vessel optics. Following collection, the emission is split into orthogonal polarizations and transmitted to the detection instruments via waveguides filled with dry nitrogen, a choice that simplifies construction and analysis. Near the instruments, a switchyard is used to select which polarization and view is detected by each instrument. The design for the radiometer used for 5.3 T will be described in detail. Supported by PPPL/US-DA via subcontract S013464-H to UT Austin.

  10. The Autism Diagnostic Observation Schedule--Toddler Module: A New Module of a Standardized Diagnostic Measure for Autism Spectrum Disorders

    Science.gov (United States)

    Luyster, Rhiannon; Gotham, Katherine; Guthrie, Whitney; Coffing, Mia; Petrak, Rachel; Pierce, Karen; Bishop, Somer; Esler, Amy; Hus, Vanessa; Oti, Rosalind; Richler, Jennifer; Risi, Susan; Lord, Catherine

    2009-01-01

    The Autism Diagnostic Observation Schedule (ADOS; Lord et al., J Autism Dev Disord, 30(3):205-223, 2000) is widely accepted as a "gold standard" diagnostic instrument, but it is of restricted utility with very young children. The purpose of the current project was to modify the ADOS for use in children under 30 months of age. A modified ADOS, the…

  11. A new framework for designing programmes of assessment.

    Science.gov (United States)

    Dijkstra, J; Van der Vleuten, C P M; Schuwirth, L W T

    2010-08-01

    Research on assessment in medical education has strongly focused on individual measurement instruments and their psychometric quality. Without detracting from the value of this research, such an approach is not sufficient to high quality assessment of competence as a whole. A programmatic approach is advocated which presupposes criteria for designing comprehensive assessment programmes and for assuring their quality. The paucity of research with relevance to programmatic assessment, and especially its development, prompted us to embark on a research project to develop design principles for programmes of assessment. We conducted focus group interviews to explore the experiences and views of nine assessment experts concerning good practices and new ideas about theoretical and practical issues in programmes of assessment. The discussion was analysed, mapping all aspects relevant for design onto a framework, which was iteratively adjusted to fit the data until saturation was reached. The overarching framework for designing programmes of assessment consists of six assessment programme dimensions: Goals, Programme in Action, Support, Documenting, Improving and Accounting. The model described in this paper can help to frame programmes of assessment; it not only provides a common language, but also a comprehensive picture of the dimensions to be covered when formulating design principles. It helps identifying areas concerning assessment in which ample research and development has been done. But, more importantly, it also helps to detect underserved areas. A guiding principle in design of assessment programmes is fitness for purpose. High quality assessment can only be defined in terms of its goals.

  12. EURATOM, the year 2000 and its impact on the reporting system and instrumentation

    International Nuclear Information System (INIS)

    Chare, P.J.

    1999-01-01

    Presentation includes the Y2K potential problem areas, its impact on the reporting system and instrumentation as well as achievements done so far. The potential problem areas are: reporting system, headquarters system, installed instrumentation and stand alone instrumentation. A complete list of EURATOM equipment is listed. Specific problem areas concerned include data acquisition programmes. Reporting system is Y2K compatible, headquarters systems will be after upgrading, problems concerning instrumentation are identified and will be upgraded in 1999

  13. Diagnostics on Z (invited)

    International Nuclear Information System (INIS)

    Nash, T. J.; Derzon, M. S.; Chandler, G. A.; Fehl, D. L.; Leeper, R. J.; Porter, J. L.; Spielman, R. B.; Ruiz, C.; Cooper, G.; McGurn, J.

    2001-01-01

    The 100 ns, 20 MA pinch-driver Z is surrounded by an extensive set of diagnostics. There are nine radial lines of sight set at 12 o above horizontal and each of these may be equipped with up to five diagnostic ports. Instruments routinely fielded viewing the pinch from the side with these ports include x-ray diode arrays, photoconducting detector arrays, bolometers, transmission grating spectrometers, time-resolved x-ray pinhole cameras, x-ray crystal spectrometers, calorimeters, silicon photodiodes, and neutron detectors. A diagnostic package fielded on axis for viewing internal pinch radiation consists of nine lines of sight. This package accommodates virtually the same diagnostics as the radial ports. Other diagnostics not fielded on the axial or radial ports include current B-dot monitors, filtered x-ray scintillators coupled by fiber optics to streak cameras, streaked visible spectroscopy, velocity interferometric system for any reflector, bremsstrahlung cameras, and active shock breakout measurement of hohlraum temperature. The data acquisition system is capable of recording up to 500 channels and the data from each shot is available on the Internet. A major new diagnostic presently under construction is the BEAMLET backlighter. We will briefly describe each of these diagnostics and present some of the highest-quality data from them

  14. Beam instrumentation for the Tevatron Collider

    Energy Technology Data Exchange (ETDEWEB)

    Moore, Ronald S.; Jansson, Andreas; Shiltsev, Vladimir; /Fermilab

    2009-10-01

    The Tevatron in Collider Run II (2001-present) is operating with six times more bunches and many times higher beam intensities and luminosities than in Run I (1992-1995). Beam diagnostics were crucial for the machine start-up and the never-ending luminosity upgrade campaign. We present the overall picture of the Tevatron diagnostics development for Run II, outline machine needs for new instrumentation, present several notable examples that led to Tevatron performance improvements, and discuss the lessons for future colliders.

  15. Quality assurance of nuclear medicine instruments

    International Nuclear Information System (INIS)

    Soni, P.S.

    1998-01-01

    Quality assurance in nuclear medicine refers collectively to all aspects of a nuclear medicine programme that may contribute directly or indirectly to the quality of the results obtained. For examples, patients scheduling; preparation and dispensing of radiopharmaceutical; the protection of patients, staff and the general public against radiation hazards and accidents caused by faulty instruments; methodology, data interpretation and record keeping

  16. Energy-efficiency instruments in the electricity area

    International Nuclear Information System (INIS)

    Hammer, S.; Oettli, B.; Schneider, Ch.; Iten, R.; Peherstorfer, N.

    2007-06-01

    This comprehensive report for the Swiss Federal Office of Energy (SFOE) describes a mix of instruments that could increase the efficiency of electricity usage in Switzerland. The basis for the development of these instruments - the experience gained in Europe in this area - is discussed. Explicitly not discussed are energy and electricity steering taxes, which could also be part of a future instrument-mix. The measures suggested include the setting of compulsory long-term reduction targets that are to form the basis for strategies and measures to be taken in particular areas and the development of an appropriate instrument-mix for this purpose. These could include regulations and labels, a national fund and certificate trading. Suppliers of electricity could be committed to increasing the efficiency of electricity use and national programmes could also attempt to influence consumer habits. The instruments should, according to the authors, be based on the existing legal framework and use know-how and structures that are already available

  17. Das Mentoring-Programm als soziales Lernarrangement im wissenschaftlichen Qualifikationsprozess: Ein Beitrag zur theoretischen Fundierung von Mentoring-Programmen

    OpenAIRE

    Lödermann, Anne-Marie

    2013-01-01

    Mentoring-Programme sind in den letzten zwei Jahrzehnten zu einem bewährten Instrument der gleichstellungsorientierten Nachwuchsförderung geworden und finden sich nahezu an jeder deutschen Universität. Die konzeptionelle Ausgestaltung der Programme variiert dabei erheblich. Über den Einfluss derartiger Programme auf die wissenschaftliche Karriereentwicklung und über den Stellenwert der arrangierten mentoralen Beziehungen im Gesamtbeziehungsgefüge der teilnehmenden Wissenschaftlerinnen ist bis...

  18. An instrument to perform automated quality assurance and patient dosimetry in diagnostic radiology

    International Nuclear Information System (INIS)

    Chapple, C.-L.; Faulkner, K.

    1992-01-01

    A computerised method of automatically monitoring tube and generator parameters to perform on-line quality assurance and patient dosimetry has been developed. A microcomputer has been interfaced to a microprocessor controlled X ray generator and dose-area product meter. The instrument prompts the operator to enter details of the examination and projection before an examination is made. The field size and dose-area product are monitored by the instrument. These data, together with information on the tube potential are used to deduce the patient entrance dose and energy imparted. Organ doses are estimated using normalised organ dose data. The accuracy and reproducibility of the instrument were investigated. Doses measured in a Rando phantom were compared with calculations made by the instrument. The instrument will compare various measured quality assurance parameters against their nominal values. The implications of this instrument for both patient dosimetry studies and effective continuous quality assurance are discussed. (author)

  19. Diagnostics of transparent polymer coatings of metal items

    Science.gov (United States)

    Varepo, L. G.; Ermakova, I. N.; Nagornova, I. V.; Kondratov, A. P.

    2017-08-01

    The methods of visual and instrumental express diagnostics of safety critical defects and non-uniform thickness of transparent mono- and multilayer polyolefin surface coating of metal items are analyzed in the paper. The instrumental diagnostics method relates to colorimetric measuring based on effects, which appear in the polarized light for extrusion polymer coatings. A color coordinates dependence (in the color system CIE La*b*) on both HDPE / PVC coating thickness fluctuation values (from average ones) and coating interlayer or adhesion layer delaminating is shown. A variation of color characteristics in the polarized light at a liquid penetration into delaminated polymer layers is found. Measuring parameters and critical uncertainties are defined.

  20. Ultrasonic imaging with a fixed instrument configuration

    Energy Technology Data Exchange (ETDEWEB)

    Witten, A.; Tuggle, J.; Waag, R.C.

    1988-07-04

    Diffraction tomography is a technique based on an inversion of the wave equation which has been proposed for high-resolution ultrasonic imaging. While this approach has been considered for diagnostic medical applications, it has, until recently, been limited by practical limitations on the speed of data acquisition associated with instrument motions. This letter presents the results of an experimental study directed towards demonstrating tomography utilizing a fixed instrument configuration.

  1. Quality assurance of medical education in the Netherlands: programme or systems accreditation? [

    Directory of Open Access Journals (Sweden)

    Hillen, Harry F. P.

    2010-04-01

    Full Text Available [english] Accreditation is an instrument that is used worldwide to monitor, maintain and improve the quality of medical education. International standards have been defined to be used in reviewing and evaluating the quality of education. The organization and the process of accreditation of medical education programmes in the Netherlands and in Flanders are described in some detail. Accreditation can be based on the results of a detailed assessment of an educational programme or on an evaluation of the educational system and the organization of the institution in question. The Flemish-Dutch accreditation organization (NAO is moving from programme accreditation towards a combination of programme and systems accreditation. The pros and cons of these two approaches are discussed.

  2. Programmable high power beam damper for the Tevatron

    International Nuclear Information System (INIS)

    Crisp, J.; Goodwin, R.; Gerig, R.

    1985-06-01

    A bunch-by-bunch beam damper has been developed for the Fermilab Tevatron. The system reduces betatron oscillation amplitudes and incorporates some useful machine diagnostics. The device is programmable via look-up tables so the output is an arbitrary function, on a bunch-by-bunch basis, of the beam displacement. We are presently using this feature to measure the betatron tune throughout the acceleration cycle. 4 refs

  3. SOME ISSUES OF DIAGNOSTICS IN IMMUNE PATHOLOGY

    OpenAIRE

    I. A. Tousankina

    2010-01-01

    Present lecture contains an author's opinion concerning diagnostic issues in immunopathology, including primary and secondary immune deficiencies, immune-dependent states that are based on immunopathological syndromes. Original formulations are suggested for some key categories of clinical immunology, physical, instrumental and laboratory diagnostics of immune deficiencies and immune-dependent diseases. The results of original long-term observations, as well as data on Sverdlovsk Regional Reg...

  4. Application of a child abuse prevention programme in an educational context

    Directory of Open Access Journals (Sweden)

    Juan M. Moreno-Manso

    2014-10-01

    Full Text Available This study analyses the effectiveness of a child abuse prevention programme in an educational context. The proposal for action is based on the use of stories as an instrument of primary prevention. The programme aims to improve a child's capacity to face potentially threatening situations and was applied in 10 primary schools of Extremadura (Spain to 317 pupils aged 9 and 10 years old. There were 12 sessions whose aim was for the children to gain an awareness of abuse, identify situations of abuse and learn strategies to face them. This was done through the use of tutorials and by linking the programme to the aims of the pupils' educational stage. The evaluation of the programme shows that the pupils in the experimental group resolved the situations with increasing skill, confidence and determination; and that they could see more clearly where to look for help in terms of protection measures. The tutors evaluated the programme positively, considering the contents useful for prevention.

  5. Energy economics basics - Emphasis programme 2004 - 2007

    International Nuclear Information System (INIS)

    Gutzwiller, L.

    2005-01-01

    This report from the Swiss Federal Office of Energy (SFOE) examines the work done within the framework of the interdisciplinary energy economics programme on scenarios and instruments for energy policy-making and economics, as well as on social and environmental aspects. The report reviews the emphasis and goals of the next phase of the programme for the period 2004 - 2007. A research road map is discussed that is to identify promising technologies that will provide a substantial contribution to meeting the goal of creating the so-called '2000-Watt Society'. The road map is to also help identify technologies that provide socio-economic advantages and identify bottlenecks and restraints on the propagation of energy-efficient technologies in the building and transport areas

  6. Lessons for Teachers: What Lower Secondary School Students Tell Us about Learning a Musical Instrument

    Science.gov (United States)

    Lowe, Geoffrey

    2012-01-01

    In this study I set out to investigate why many students drop out from elective instrument programmes, particularly in lower secondary school. I examined the values and beliefs a sample of students in their first year in secondary school attach to learning an instrument, and the impact of the instrument lesson upon these values and beliefs.…

  7. UPTF test instrumentation. Measurement system identification, engineering units and computed parameters

    International Nuclear Information System (INIS)

    Sarkar, J.; Liebert, J.; Laeufer, R.

    1992-11-01

    This updated version of the previous report /1/ contains, besides additional instrumentation needed for 2D/3D Programme, the supplementary instrumentation in the inlet plenum of SG simulator and hot and cold leg of broken loop, the cold leg of intact loops and the upper plenum to meet the requirements (Test Phase A) of the UPTF Programme, TRAM, sponsored by the Federal Minister of Research and Technology (BMFT) of the Federal Republic of Germany. For understanding, the derivation and the description of the identification codes for the entire conventional and advanced measurement systems classifying the function, and the equipment unit, key, as adopted in the conventional power plants, have been included. Amendments have also been made to the appendices. In particular, the list of measurement systems covering the measurement identification code, instrument, measured quantity, measuring range, band width, uncertainty and sensor location has been updated and extended to include the supplementary instrumentation. Beyond these amendments, the uncertainties of measurements have been precisely specified. The measurement identification codes which also stand for the identification of the corresponding measured quantities in engineering units and the identification codes derived therefrom for the computed parameters have been adequately detailed. (orig.)

  8. New proposal on the development of machine protection functions for ITER diagnostics control

    International Nuclear Information System (INIS)

    Yamamoto, Tsuyoshi; Yatsuka, Eiichi; Hatae, Takaki; Takeuchi, Masaki; Kitazawa, Sin-iti; Ogawa, Hiroaki; Kawano, Yasunori; Itami, Kiyoshi; Ota, Kazuya; Hashimoto, Yasunori; Nakamura, Kitaru; Sugie, Tatsuo

    2016-01-01

    There is a need to develop ITER instrumentation and control (I and C) systems with high reliabilities. Interlock systems that activate machine protection functions are implemented on robust wired-logic systems such as programmable logic controllers (PLCs). We herein propose a software tool that generates program code templates for the control systems using PLC logic. This tool decreases careless mistakes by developers and increases reliability of the program codes. A large-scale engineering database has been implemented in the ITER project. To derive useful information from this database, we propose adding semantic data to it using the Resource Description Framework format. In our novel proposal for the ITER diagnostic control system, a guide words generator that analyzes the engineering data by inference is applied to the hazard and operability study. We validated the methods proposed in this paper by applying them to the preliminary design for the I and C system of the ITER edge Thomson scattering system. (author)

  9. Energy saving certificates: an improved instrument

    International Nuclear Information System (INIS)

    2016-02-01

    This report first presents Energy Saving Certificates as one of among other instruments aimed at reducing energy consumption, and indicates how the French consumer is concerned. The benefits of this instrument are outlined: low cost, autonomy, awareness-raising, quantitative assessment of achieved energy savings. Its objectives and results since its creation in 2006 are commented, and the report outlines that this type of instrument is spreading over Europe. The authors show that its efficiency has been improved along the years due to a periodic review of standardised operation sheets, a simplification of the declaration, and an optimization of related programmes. Besides, targets have been better identified. The report outlines that assessment and controls must however be strengthened in order to reduce financial risks and potential drifts. Answers to this report by the concerned minister and ADEME are provided

  10. FUNCTIONAL FECAL INCONTINENCE IN CHILDREN (DIFFERENTIAL DIAGNOSTICS AND TREATMENT APPROACHES

    Directory of Open Access Journals (Sweden)

    V.N. Kopeikin

    2009-01-01

    Full Text Available Impairment of the intestinal content continence, a common clinical situation with various pathogenetic mechanisms. Disease proceeds with the child’s maladjustment events. 33 cases of encopresis have been analyzed. This condition has various clinical and instrumental diagnostic criteria depending on the origin which simplifies differential diagnostics. Using a differential diagnostics table helps expedite the process of making a diagnosis and hence start an adequate treatment in a timely manner.Key words: encopresis, differential diagnostics, treatment, children.

  11. Automation of a thermal expansion instrument

    Energy Technology Data Exchange (ETDEWEB)

    Holland, L.L.

    1979-03-01

    Automation of a thermal expansion instrument using a minicomputer system and with analog-to-digital converter inputs and flip-flop relay outputs is described. The necessary hardware link and the software were developed to allow equipment control, data acquisition, data reduction, and report generation by the minicomputer. The design of the automation allows non-programmers to run the experiment, reduce the data, and generate the report.

  12. Modernization of ILL instrument electronics

    International Nuclear Information System (INIS)

    Descamps, F.

    1999-01-01

    We have built new general purpose cards for data acquisition taking advantage of recent developments in electronics. At the end of the year, most scheduled instruments at the ILL will be running under UNIX with VME electronics front-end. As the VME electronics of the ILL was designed at the beginning of the eighties, the instrument control section (SCI) at ILL has prepared a renewal plan for two reasons: - first, all the processor cards of the Institute are based on MIZAR processor boards and MIZAR stopped the production of this card last year, as the market was shrinking; - in addition, processors and programmable electronics are now 10 times faster. The electronics services want to take full advantage of these new performances. (author)

  13. Animal trypanosomosis: Diagnosis and epidemiology. Results of a FAO/IAEA co-ordinated research programme on the use of immunoassay methods for improved diagnosis of trypanosomosis and monitoring tsetse and trypanosomosis control programmes

    International Nuclear Information System (INIS)

    2000-01-01

    One of the tasks of the Joint FAO/IAEA Division of Nuclear Techniques in Food and Agriculture is to promote the use of nuclear techniques for improving disease diagnosis and monitoring disease control programmes in order to optimise animal production in developing countries. An applied research programme was initiated in 1987 with funding from the Government of the Netherlands to validate an ELISA to detect trypanosomal antigens developed by the International Laboratory for Research on Animal Diseases (ILRAD). The test was successfully validated in ten different laboratories in Africa through a Co-ordinated Research Programme (CRP) from 1987-1993 entitled ''Improving the diagnosis and control of trypanosomosis and other vector-borne diseases of African livestock using immunoassay methods''. Results indicated a reasonable, but at times variable sensitivity and specificity (published in IAEA-TECDOC-707). During an additional two-year period (1993-1995) the IAEA Department of Technical Co-operation and the Joint FAO/IAEA Division of Nuclear Techniques in Food and Agriculture provided support for a Regional Technical Co-operation Project (TCP) to strengthen disease diagnostic capabilities in the National Agricultural Research Systems (NARS) with a special emphasis on the diagnosis of trypanosomosis. Results of the TCP were published in IAEA-TECDOC-925 and were encouraging enough to request additional funding from the Government of the Netherlands for a five-year programme to enable application of the assay as a tool for monitoring disease control programmes in Africa. The results of the latter programme are reported in the present publication together with a number of review articles on the diagnostic and epidemiological aspects of the disease in African livestock

  14. CAP vessel monitoring. Programme, measurement and neutron calculation

    International Nuclear Information System (INIS)

    Farrugia, J.M.; Nimal, J.C.; Totth, B.; Lloret, R.; Perdreau, R.

    1982-03-01

    Starting with the design of the CAP (Prototype Advanced NSSS), a programme for pressure vessel monitoring has been prepared, including dosimetry. The dosimetry programme encompasses activation dosimeters (Cu, Nb, Co) and fission dosimeters ( 237 Np, 238 U) installed either inside the pressure vessel with the monitoring test-samples, or in a counting tube outside the pressure vessel. In the first place, a description of the method for neutronic calculation is given; such calculations use the codes ANISN and MERCURE 4 allowing assessment of the neutron spectrum seen by the detectors and the related reaction coefficient. This is followed by a description of the instrumentation. The initial dosimetry results available after the initial operating cycles concur with calculations [fr

  15. The WHO AFRO external quality assessment programme (EQAP: Linking laboratory networks through EQA programmes

    Directory of Open Access Journals (Sweden)

    Debrah I. Boeras

    2016-10-01

    Full Text Available External Quality Assessment (EQA surveys performed by the World Health Organization Regional Office for Africa (WHO AFRO revealed the need for the strengthening of publichealth microbiology laboratories, particularly for testing of epidemic-prone diseases in theAfrican Region. These surveys revealed common issues such as supply chain managementskilled personnel, logistical support and overall lack of quality standards. For sustainableimprovements to health systems as well as global health security, deficiencies identified needto be actively corrected through robust quality assurance programmes and implementation oflaboratory quality management systems. Given all the pathogens of public health importance, an external quality assessment programmewith a focus on vaccine-preventable diseases and emerging and re-emerging dangerouspathogens is important, and should not be stand-alone, but integrated within laboratorynetworks as seen in polio, measles, yellow fever and rubella. In 2015, WHO AFRO collaborated with the US Centers for Disease Control and Preventionthe London School of Hygiene & Tropical Medicine and partners in a series of consultationswith countries and national and regional EQA providers for the development of qualityassurance models to support HIV point-of-care testing and monitoring. These consultationsrevealed similar challenges as seen in the WHO AFRO surveys. WHO AFRO brought forthits experience in implementing quality standards for health programmes, and also openeddiscussions on how lessons learned through such established programmes can be utilised tosupporting and strengthening the introduction of early infant diagnosis of HIV and viralload point-of-care testing. An optimised external quality assessment programme will impact the ability of countries tomeet core capacities, providing improved quality management systems, improving theconfidence of diagnostic network services in Africa, and including capacities to detect eventsof

  16. Nuclear power plant control and instrumentation in Italy

    International Nuclear Information System (INIS)

    Lantieri, A.

    1992-01-01

    The National Energy Plan (PEN) approved by the Government of Italy in August 1988 provides a programme of research and industrial development or reactors with inherent and passive safety features. For the Control Systems and Instrumentation there is the aim to define rules and design criteria, by evaluating the impact of inherent safety goals on the C and I design. The effort on man-machine interface is considered essential to increase safety and efficiency of advanced reactors. The paper briefly describes the activity in control systems and in the instrumentation area. (author)

  17. Energy-efficiency instruments in the electricity area; Instrumente fuer Energieeffizienz im Elektrizitaetsbereich. Auslaendische Erfahrungen und Instrumenten-Mix fuer die Schweiz

    Energy Technology Data Exchange (ETDEWEB)

    Hammer, S; Oettli, B; Schneider, Ch; Iten, R [Infras, Zuerich (Switzerland); Peherstorfer, N [Oesterreichische Energieagentur, Wien (Austria)

    2007-06-15

    This comprehensive report for the Swiss Federal Office of Energy (SFOE) describes a mix of instruments that could increase the efficiency of electricity usage in Switzerland. The basis for the development of these instruments - the experience gained in Europe in this area - is discussed. Explicitly not discussed are energy and electricity steering taxes, which could also be part of a future instrument-mix. The measures suggested include the setting of compulsory long-term reduction targets that are to form the basis for strategies and measures to be taken in particular areas and the development of an appropriate instrument-mix for this purpose. These could include regulations and labels, a national fund and certificate trading. Suppliers of electricity could be committed to increasing the efficiency of electricity use and national programmes could also attempt to influence consumer habits. The instruments should, according to the authors, be based on the existing legal framework and use know-how and structures that are already available.

  18. New technology in nuclear power plant instrumentation and control

    International Nuclear Information System (INIS)

    Anon.

    1985-01-01

    The primary topic of this book is what can be done to improve nuclear power plant operation safety and the economic benefits that can be gained with the utilization of advance instrumentation and control technology. Other topics discussed are the industry's reluctance to accept new designs determining cost effective improvements, and difficulties in meeting regulatory standards with new technology control. The subjects will be useful when considering the area of instrumentation and control for enhancing plant operation and safety. Contents: Advanced Instrumention, Plant Control and Monitoring, Plant Diagnostics and Failure Detection, Human Factors Considerations in Instrumentation and Control, NRC and Industry Perspective on Advanced Instrumentation and Control

  19. Development of global data warehouse for beam diagnostics at SSRF

    International Nuclear Information System (INIS)

    Lai Longwei; Leng Yongbin; Yan Yingbing; Chen Zhichu

    2015-01-01

    The beam diagnostic system is adequate during the daily operation and machine study at the Shanghai Synchrotron Radiation Facility (SSRF). Without the effective event detecting mechanism, it is difficult to dump and analyze abnormal phenomena such as the global orbital disturbance, the malfunction of the BPM and the noise of the DCCT. The global beam diagnostic data warehouse was built in order to monitor the status of the accelerator and the beam instruments. The data warehouse was designed as a Soft IOC hosted on an independent server. Once abnormal phenomena happen it will be triggered and will store the relevant data for further analysis. The results show that the data warehouse can detect abnormal phenomena of the machine and the beam diagnostic system effectively, and can be used for calculating confidential indicators of the beam instruments. It provides an efficient tool for the improvement of the beam diagnostic system and accelerator. (authors)

  20. TMI-2 instrumentation and electrical program final evaluation report

    International Nuclear Information System (INIS)

    Mayo, C.W.; Huzdovich, J.W.; Roby, A.R.; Test, L.D.

    1986-11-01

    This report presents the authors collective opinions on the value to the nuclear industry of the various investigations performed at TMI-2 by the Instrumentation and Electrical Program. The authors demonstrate that more attention must be given to the prevention of moisture intrusion during design, construction, operation, and maintenance of a nuclear power plant. They also point out that, while basic engineering designs of instruments are more than adequate, the applications engineering and specifications could be improved. Finally, they show that advanced testing technology, exemplified by the Electrical Circuit Characterization and Diagnostics (ECCAD) System, may be very useful as a diagnostic tool when used as part of the testing or maintenance program in a nuclear power plant

  1. Optical Methods and Instrumentation in Brain Imaging and Therapy

    CERN Document Server

    2013-01-01

    This book provides a comprehensive up-to-date review of optical approaches used in brain imaging and therapy. It covers a variety of imaging techniques including diffuse optical imaging, laser speckle imaging, photoacoustic imaging and optical coherence tomography. A number of laser-based therapeutic approaches are reviewed, including photodynamic therapy, fluorescence guided resection and photothermal therapy. Fundamental principles and instrumentation are discussed for each imaging and therapeutic technique. Represents the first publication dedicated solely to optical diagnostics and therapeutics in the brain Provides a comprehensive review of the principles of each imaging/therapeutic modality Reviews the latest advances in instrumentation for optical diagnostics in the brain Discusses new optical-based therapeutic approaches for brain diseases

  2. PLC/DTAM Software Programs for Pumping Instrumentation and Control Skid ''L''

    International Nuclear Information System (INIS)

    KOCH, M.R.

    2000-01-01

    This document describes the software programs for the Programmable Logic Controller and the Data Table Access Module for Pumping Instrumentation and Control skid ''L''. The Appendices contains copies of the printouts of these software programs

  3. Modelling of JET diagnostics using Bayesian Graphical Models

    Energy Technology Data Exchange (ETDEWEB)

    Svensson, J. [IPP Greifswald, Greifswald (Germany); Ford, O. [Imperial College, London (United Kingdom); McDonald, D.; Hole, M.; Nessi, G. von; Meakins, A.; Brix, M.; Thomsen, H.; Werner, A.; Sirinelli, A.

    2011-07-01

    The mapping between physics parameters (such as densities, currents, flows, temperatures etc) defining the plasma 'state' under a given model and the raw observations of each plasma diagnostic will 1) depend on the particular physics model used, 2) is inherently probabilistic, from uncertainties on both observations and instrumental aspects of the mapping, such as calibrations, instrument functions etc. A flexible and principled way of modelling such interconnected probabilistic systems is through so called Bayesian graphical models. Being an amalgam between graph theory and probability theory, Bayesian graphical models can simulate the complex interconnections between physics models and diagnostic observations from multiple heterogeneous diagnostic systems, making it relatively easy to optimally combine the observations from multiple diagnostics for joint inference on parameters of the underlying physics model, which in itself can be represented as part of the graph. At JET about 10 diagnostic systems have to date been modelled in this way, and has lead to a number of new results, including: the reconstruction of the flux surface topology and q-profiles without any specific equilibrium assumption, using information from a number of different diagnostic systems; profile inversions taking into account the uncertainties in the flux surface positions and a substantial increase in accuracy of JET electron density and temperature profiles, including improved pedestal resolution, through the joint analysis of three diagnostic systems. It is believed that the Bayesian graph approach could potentially be utilised for very large sets of diagnostics, providing a generic data analysis framework for nuclear fusion experiments, that would be able to optimally utilize the information from multiple diagnostics simultaneously, and where the explicit graph representation of the connections to underlying physics models could be used for sophisticated model testing. This

  4. Regulatory requirements and quality assurance of radiation monitoring instruments

    International Nuclear Information System (INIS)

    Narasimharao, K.L.; Sharma, Ranjit

    2005-01-01

    The successful utilisation of radiation sources in the fields of medicine and industry requires the accurate measurement of activity, exposure rate and dose. Many varieties of instruments are in use for measurement of these parameters and new ones are being developed. The criteria for the design of the radiation monitoring instrument include the type and intensity of the radiation, purpose of measurement and ruggedness of the instrument. Quality and reliability of radiation monitoring instruments ensure that individuals are adequately protected. Accuracy, response time and ruggedness are required to be as per the approved/ prescribed guidelines. Regulatory authorities outline the design and performance criteria for radiation monitoring instruments and prescribe the recommendations of international agencies such as IAEA, ICRU and ISO for radiological measurement assurance programme. National Standards Laboratories all over the world prescribe procedures for calibration of various radiation monitoring instruments. The instruments should be calibrated as per these guidelines and should be traceable to national standards. The calibration traceable to national/ international standards and documentation as well as limits stipulated by the competent authority ensures the expected performance of the instrument. (author)

  5. Excessive exposures of diagnostic X-ray workers in India

    International Nuclear Information System (INIS)

    Ambiger, T.Y.; Shenoy, K.S.; Patel, P.H.

    1980-01-01

    The excessive exposures (i.e. exceeding 400 mrems per fortnight) of diagnostic X-ray workers revealed under the countrywide personnel monitoring programme in India have been analysed. The analysis covers the data collected over a period of ten years during 1965-1974. The radiation workers in medical X-ray diagnostic group receiving an excess dose are found to be less than 1%. Each case of the excess dose is throughly investigated and nongenuine cases are separated and causes for genuine excessive exposures are traced. The causes and the corrective measures are enumerated. (M.G.B.)

  6. Plans for the CIT [Compact Ignition Tokamak] instrumentation and control system

    International Nuclear Information System (INIS)

    Preckshot, G.G.

    1987-01-01

    Extensive experience with previous fusion experiments (TFTR, MFTF-B and others) is driving the design of the Instrumentation and Control System (I and C) for the Compact Ignition Tokamak (CIT) to be built at Princeton. The new design will reuse much equipment from TFTR and will be subdivided into six major parts: machine control, machine data acquisition, plasma diagnostic instrument control and instrument data acquisition, the database, shot sequencing and safety interlocks. In a major departure from previous fusion experiment control systems, the CIT machine control system will be a commercial process control system. Since the machine control system will be purchased as a completely functional product, we will be able to concentrate development manpower in plasma diagnostic instrument control, data acquisition, data processing and analysis, and database systems. We will discuss the issues driving the design, give a design overview and state the requirements upon any prospective commercial process control system

  7. Particle size distribution instrument. Topical report 13

    Energy Technology Data Exchange (ETDEWEB)

    Okhuysen, W.; Gassaway, J.D.

    1995-04-01

    The development of an instrument to measure the concentration of particles in gas is described in this report. An in situ instrument was designed and constructed which sizes individual particles and counts the number of occurrences for several size classes. Although this instrument was designed to detect the size distribution of slag and seed particles generated at an experimental coal-fired magnetohydrodynamic power facility, it can be used as a nonintrusive diagnostic tool for other hostile industrial processes involving the formation and growth of particulates. Two of the techniques developed are extensions of the widely used crossed beam velocimeter, providing simultaneous measurement of the size distribution and velocity of articles.

  8. Chapter 7: Diagnostics [Progress in the ITER Physics Basis (PIPB)

    International Nuclear Information System (INIS)

    Donne, A.J.H.; Costley, A.E.; Barnsley, R.

    2007-01-01

    In order to support the operation of ITER and the planned experimental programme an extensive set of plasma and first wall measurements will be required. The number and type of required measurements will be similar to those made on the present-day large tokamaks while the specification of the measurements-time and spatial resolutions, etc-will in some cases be more stringent. Many of the measurements will be used in the real time control of the plasma driving a requirement for very high reliability in the systems (diagnostics) that provide the measurements. The implementation of diagnostic systems on ITER is a substantial challenge. Because of the harsh environment (high levels of neutron and gamma fluxes, neutron heating, particle bombardment) diagnostic system selection and design has to cope with a range of phenomena not previously encountered in diagnostic design. Extensive design and R and D is needed to prepare the systems. In some cases the environmental difficulties are so severe that new diagnostic techniques are required. The starting point in the development of diagnostics for ITER is to define the measurement requirements and develop their justification. It is necessary to include all the plasma parameters needed to support the basic and advanced operation (including active control) of the device, machine protection and also those needed to support the physics programme. Once the requirements are defined, the appropriate (combination of) diagnostic techniques can be selected and their implementation onto the tokamak can be developed. The selected list of diagnostics is an important guideline for identifying dedicated research and development needs in the area of ITER diagnostics. This paper gives a comprehensive overview of recent progress in the field of ITER diagnostics with emphasis on the implementation issues. After a discussion of the measurement requirements for plasma parameters in ITER and their justifications, recent progress in the field of

  9. Laboratory Information Systems in Molecular Diagnostics: Why Molecular Diagnostics Data are Different.

    Science.gov (United States)

    Lee, Roy E; Henricks, Walter H; Sirintrapun, Sahussapont J

    2016-03-01

    Molecular diagnostic testing presents new challenges to information management that are yet to be sufficiently addressed by currently available information systems for the molecular laboratory. These challenges relate to unique aspects of molecular genetic testing: molecular test ordering, informed consent issues, diverse specimen types that encompass the full breadth of specimens handled by traditional anatomic and clinical pathology information systems, data structures and data elements specific to molecular testing, varied testing workflows and protocols, diverse instrument outputs, unique needs and requirements of molecular test reporting, and nuances related to the dissemination of molecular pathology test reports. By satisfactorily addressing these needs in molecular test data management, a laboratory information system designed for the unique needs of molecular diagnostics presents a compelling reason to migrate away from the current paper and spreadsheet information management that many molecular laboratories currently use. This paper reviews the issues and challenges of information management in the molecular diagnostics laboratory.

  10. BOMBAY: Instrumentation school

    International Nuclear Information System (INIS)

    Anon.

    1993-01-01

    Full text: Promising students had a foretaste of the latest laboratory techniques at the ICFA 1993 India School on Instrumentation in High Energy Physics held from February 15-26 and hosted by the Tata Institute of Fundamental Research (TIFR), Bombay. The scientific programme was put together by the ICFA Panel for Future Instrumentation, Innovation and Development, chaired by Tord Ekelof (Uppsala). The programme included lectures and topical seminars covering a wide range of detector subjects. In small groups, students got acquainted with modern detector technologies in the laboratory sessions, using experimental setups assembled in various institutes world-wide and shipped to Bombay for the School. The techniques covered included multiwire proportional chambers for detection of particles and photons, gaseous detectors for UV photons and X-ray imaging, the study of charge drift in silicon detectors, measurement of the muon lifetime using liquid scintillators, tracking using scintillating fibres, and electronics for sensitive detectors. The India School was attended by around 80 students from 20 countries; 34 came from Indian universities. It was the fifth in this series, previous Schools having been at Trieste (1987, 1989 and 1991) organized by the ICFA Panel and hosted and sponsored by the International Centre for Theoretical Physics, and in 1990, organized at Rio de Janeiro in collaboration with the Centro Brasileiro de Pesquisas Fisicas. The School was jointly directed by Suresh Tonwar (TIFR), Fabio Sauli (CERN) and Marleigh Sheaff (University of Wisconsin), and sponsored by TIFR and DAE (India), CERN (Switzerland), ICTP and INFN (Italy), British Council and RAL (UK), NSF and DOE (USA), KEK (Japan), IPP (Canada) and DESY (Germany)

  11. SOME ISSUES OF DIAGNOSTICS IN IMMUNE PATHOLOGY

    Directory of Open Access Journals (Sweden)

    I. A. Tousankina

    2010-01-01

    Full Text Available Present lecture contains an author's opinion concerning diagnostic issues in immunopathology, including primary and secondary immune deficiencies, immune-dependent states that are based on immunopathological syndromes. Original formulations are suggested for some key categories of clinical immunology, physical, instrumental and laboratory diagnostics of immune deficiencies and immune-dependent diseases. The results of original long-term observations, as well as data on Sverdlovsk Regional Register of primary immune deficiencies are presented in the work.

  12. Field Programmable Gate Array-based I and C Safety System

    International Nuclear Information System (INIS)

    Kim, Hyun Jeong; Kim, Koh Eun; Kim, Young Geul; Kwon, Jong Soo

    2014-01-01

    Programmable Logic Controller (PLC)-based I and C safety system used in the operating nuclear power plants has the disadvantages of the Common Cause Failure (CCF), high maintenance costs and quick obsolescence, and then it is necessary to develop the other platform to replace the PLC. The Field Programmable Gate Array (FPGA)-based Instrument and Control (I and C) safety system is safer and more economical than Programmable Logic Controller (PLC)-based I and C safety system. Therefore, in the future, FPGA-based I and C safety system will be able to replace the PLC-based I and C safety system in the operating and the new nuclear power plants to get benefited from its safety and economic advantage. FPGA-based I and C safety system shall be implemented and verified by applying the related requirements to perform the safety function

  13. Field Programmable Gate Array-based I and C Safety System

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Hyun Jeong; Kim, Koh Eun; Kim, Young Geul; Kwon, Jong Soo [KEPCO, Daejeon (Korea, Republic of)

    2014-08-15

    Programmable Logic Controller (PLC)-based I and C safety system used in the operating nuclear power plants has the disadvantages of the Common Cause Failure (CCF), high maintenance costs and quick obsolescence, and then it is necessary to develop the other platform to replace the PLC. The Field Programmable Gate Array (FPGA)-based Instrument and Control (I and C) safety system is safer and more economical than Programmable Logic Controller (PLC)-based I and C safety system. Therefore, in the future, FPGA-based I and C safety system will be able to replace the PLC-based I and C safety system in the operating and the new nuclear power plants to get benefited from its safety and economic advantage. FPGA-based I and C safety system shall be implemented and verified by applying the related requirements to perform the safety function.

  14. Some emergency instrumentation

    Energy Technology Data Exchange (ETDEWEB)

    Burgess, P H

    1986-10-01

    The widespread release of activity and the resultant spread of contamination after the Chernobyl accident resulted in requests to NRPB to provide instruments for, and expertise in, the measurement of radiation. The most common request was for advice on the usefulness of existing instruments, but Board staff were also involved in their adaptation or in the development of new instruments specially to meet the circumstances of the accident. The accident occurred on 26 April. On 1 May, NRPB was involved at Heathrow Airport in the monitoring of the British students who had returned from Kiev and Minsk. The main purpose was to reassure the students by checking that their persons and belongings did not have significant surface contamination. Additional measurements were also made of iodine activity in thyroid using hand-held detectors or a mobile body monitor. This operation was arranged with the Foreign and Commonwealth Office, which had also received numerous requests for instruments from embassies and consulates in countries close to the scene of the accident. There was concern for the well-being of staff and other United Kingdom nationals who resided in or intended to visit the most affected countries. The board supplied suitable instruments, and the FCO distributed them to embassies. The frequency of environmental monitoring was increased from 29 April in anticipation of contamination and appropriate Board instrumentation was deployed. After the Chernobyl cloud arrived in the UK on 2 May, there were numerous requests from local government, public authorities, private companies and members of the public for information and advice on monitoring equipment and procedures. Some of these requirements could be met with existing equipment but members of the public were usually advised not to proceed. At a later stage, the contamination of foodstuffs and livestock required the development of an instrument capable of detecting low levels of {sup 137}Cs and {sup 134}Cs in food

  15. UKAEA underlying research programme annual report

    International Nuclear Information System (INIS)

    Mason, J.P.

    1988-11-01

    Work from all technical areas of the Authority's underlying research programme is described. This is typically in the form of an interim progress report for the year April 1987 to March 1988. The seventeen chapters report research into radiation damage, fracture studies, chemical effects at surfaces, surface physics and corrosion, fluid mechanics and heat transfer, nuclear studies, neutron beam studies, theoretical sciences, instrumentation, reactor physics and control, fabrication processes, laser isotope separation, nuclear fuel cycle studies, quantum electronics, radiological protection, and miscellaneous underlying research. (author)

  16. PLC and DTAM Software Programs for Pumping Instrumentation and Control Skid P

    International Nuclear Information System (INIS)

    KOCH, M.R.

    2000-01-01

    This document describe the software programs for the Programmable Logic Controller and the Datable Access Module for Pumping Instrumentation and Control skid ''P''. The Appendices contains copies of the printouts of these software programs

  17. Programme for reducing the risk factors due to prenatal exposure

    International Nuclear Information System (INIS)

    Arranz, L.; Ferrer, N.; Sastre, J.M.

    2001-01-01

    When a patient is not aware of her pregnancy, the foetus/embryo may be inadvertently irradiated during a diagnostic exploration or therapeutic intervention. The radiosensitivity of the foetus/embryo changes during the different periods of gestation. For this reason there are different risk factors for each moment at which the patient may suffer irradiation. In the past 7 years, the Department of Radiophysics and Radiation Protection has been consulted 75 times for this reason, to evaluate the dose received in the uterus. Since the establishment of a programme to avoid inadvertent irradiation of the foetus/embryo, these consultations have been reduced. This programme is based on informing the patients and on training the medical staff. (author)

  18. PLC/DTAM Software Programs for Pumping Instrumentation and Control Skid L

    Energy Technology Data Exchange (ETDEWEB)

    KOCH, M.R.

    2000-01-03

    This document describes the software programs for the Programmable Logic Controller and the Data Table Access Module for Pumping Instrumentation and Control skid ''L''. The Appendices contains copies of the printouts of these software programs.

  19. Development of PETAL diagnostics: PETAPhys project

    Science.gov (United States)

    Raffestin, D.; Boutoux, G.; Baggio, J.; Batani, D.; Blanchot, N.; Bretheau, D.; Hulin, S.; D'Humieres, E.; Granet, F.; Longhi, Th.; Meyer, Ch.; Moreno, Q.; Nuter, R.; Rault, J.; Tikhonchuk, V.; Universite de Bordeaux/Celia Team; CEA. DAM/Cesta Team

    2017-10-01

    Beginning of autumn 2017, PETAL, a Petawatt laser beam, will be operated for experiments on the LMJ facility at the CEA/ Cesta research center. The PETAPhys project provides a support to the qualification phase of the PETAL laser operation. Within the PETAPhys project, we are developing two simple and robust diagnostics permitting both to characterize the focal spot of the PETAL beam and to measure the hard X-ray spectrum at each shot. The first diagnostic consists in optical imaging of the PETAL beam focal spot in the spectral range of the second and third harmonic radiation emitted from the target. The second diagnostic is a hard X-ray dosimeter consisting in a stack of imaging plates (IP) and filters, either placed inside a re-entrant tube or inserted close to target. Numerical simulations as well as experiments on small scale facilities have been performed to design these diagnostics. If available, preliminary results from PETAL experiments will be discussed. We acknowledge the financial support from the French National Research Agency (ANR) in the framework of ``the investments for the future'' Programme IdEx Bordeaux-LAPHIA (ANR-10-IDEX-03-02).

  20. PLC and DTAM Software Programs for Pumping Instrumentation and Control Skid ''M''

    International Nuclear Information System (INIS)

    KOCH, M.R.

    2000-01-01

    This document describes the software programs for the Programmable Logic Controller and the Data Table Access Module for Pumping Instrumentation and Control skid ''M''. The Appendices contains copies of the printouts of these software programs

  1. TECHNICAL TRAINING SEMINAR: National Instruments

    CERN Multimedia

    Monique Duval

    2004-01-01

    From 9:30 to 12:00 and from 13:00 to 16:00 hrs - Council Chamber, Salle B, Salle des Pas Perdus National Instruments (NI) on Tour 2004 Claudia Jüngel, Evrem Yarkin, Joel Clerc, Hervé Baour / NATIONAL INSTRUMENTS The special event NI on Tour 2004, run in Germany, Austria and Switzerland, will be at CERN on March 30. Technical seminars and free introductory courses will be offered all day long in the Council Chamber, Salle B, and Salle des Pas Perdus (buildings 61 and 503). Data acquisition systems on PCs, industrial measurement and control techniques, advanced LabVIEW software and PXI instrumentation, and system components for tests and automation will be presented. Walk-in courses will address DIAdem, LabVIEW and data acquisition. Language: English and French Free seminars and courses, no registration Organisers: Rolf Stampfli / IT-CO / 78102 & 160367 / Rolf.Stampfli@cern.ch Davide Vitè / HR-PMD-ATT / 75141 Davide.Vite@cern.ch For more information and the complete event programme, please visit the...

  2. An instrument for X-ray set quality assurance measurements

    International Nuclear Information System (INIS)

    Willetts, R.J.; West, M.B.; Brydon, J.

    1989-01-01

    This paper describes a prototype electronic instrument for performing quality assurance (QA) measurements on diagnostic radiological equipment with a view to long-term performance assessment on a Regional basis. The instrument is based on a Tandy 200 laptop computer and has been developed primarily to include the assessment of image intensifier/TV systems in a general QA package. It is capable of accepting signals from the following sources: (1) a radiation detector (diode array); (2) a Keithley kV divider (Keithley Instruments, Inc.); (3) the video output of an image intensifier system. (author)

  3. The development and evaluation of a Biblically-based therapy programme for a congregation

    Directory of Open Access Journals (Sweden)

    N.L. Joubert

    2004-08-01

    Full Text Available The aim of the research underlying this article was to develop a Biblically-based therapy programme for a congregation and to evaluate its impact. The aim of the programme was to enhance participants’ acceptance of self, their acceptance of others and their ability to have a meaningful relationship with God. A preand post-test design that included an experimental group (n = 27 and a control group (n = 23 was used. The programme consisted of six weekly individual therapy sessions that were conducted by one of the researchers, and a support and prayer group that supported the experimental group. The impact of the programme presentation was assessed by nine measuring instruments. Results obtained indicated that the participants in the experimental group experienced significant growth in almost all the psychological and spiritual dimensions that had been assessed. It was concluded that a Biblically-based therapy programme could be used to enhance individuals’ intra-psychic, interpersonal and, ultimately, spiritual growth.

  4. Multispectral optical tweezers for molecular diagnostics of single biological cells

    Science.gov (United States)

    Butler, Corey; Fardad, Shima; Sincore, Alex; Vangheluwe, Marie; Baudelet, Matthieu; Richardson, Martin

    2012-03-01

    Optical trapping of single biological cells has become an established technique for controlling and studying fundamental behavior of single cells with their environment without having "many-body" interference. The development of such an instrument for optical diagnostics (including Raman and fluorescence for molecular diagnostics) via laser spectroscopy with either the "trapping" beam or secondary beams is still in progress. This paper shows the development of modular multi-spectral imaging optical tweezers combining Raman and Fluorescence diagnostics of biological cells.

  5. Target diagnostic system for the National Ignition Facility (NIF)

    International Nuclear Information System (INIS)

    Leeper, R.J.; Chandler, G.A.; Cooper, G.W.; Derzon, M.S.

    1996-01-01

    A review of recent progress on the design of a diagnostic system proposed for ignition target experiments on the National Ignition Facility (NIF) will be presented. This diagnostic package contains an extensive suite of optical, x-ray, gamma-ray, and neutron diagnostics that enable measurements of the performance of both direct and indirect driven NIF targets. The philosophy used in designing all of the diagnostics in the set has emphasized redundant and independent measurement of fundamental physical quantities relevant to the operation of the NIF target. A unique feature of these diagnostics is that they are being designed to be capable of operating, in the high radiation, EMP, and debris backgrounds expected on the NIF facility. The diagnostic system proposed can be categorized into three broad areas: laser characterization, hohlraum characterization, and capsule performance diagnostics. The operating principles of a representative instrument from each class of diagnostic employed in this package will be summarized and illustrated with data obtained in recent prototype diagnostic tests

  6. SNS Diagnostics Tools for Data Acquisition and Display

    CERN Document Server

    Sundaram, Madhan; Long, Cary D

    2005-01-01

    The Spallation Neutron Source (SNS) accelerator systems will deliver a 1.0 GeV, 1.4 MW proton beam to a liquid mercury target for neutron scattering research. The accelerator complex consists of a 1.0 GeV linear accelerator, an accumulator ring and associated transport lines. The SNS diagnostics platform is PC-based and will run Windows for its OS and LabVIEW as its programming language. The diagnostics platform as well as other control systems and operator consoles use the Channel Access (CA) protocol of the Experimental Physics and Industrial Control System (EPICS) to communicate. This paper describes the tools created to evaluate the diagnostic instrument using our standard programming environment, LabVIEW. The tools are based on the LabVIEW Channel Access library and can run on Windows, Linux, and Mac OS X. The data-acquisition tool uses drop and drag to select process variables organized by instrument, accelerator component, or beam parameters. The data can be viewed on-line and logged to disk for later ...

  7. kVp estimate intercomparison between Unfors XI, Radcal 4075 and a new CDTN multipurpose instrument

    International Nuclear Information System (INIS)

    Baptista Neto, A.T.; Oliveira, B.B.; Faria, L.O.

    2015-01-01

    In this work we compare the kVp estimate between CDTN multipurpose instrument, UnforsXI and Radcal 4075 meters under different combinations of voltage and filtration. The non-invasively measurements made using x-ray diagnostic and interventional radiology devices show similar tendencies to increase the kVp estimate when aluminum filters are placed in the path of the x-ray beam. The results reveal that the kVp estimate made by the CDTN multipurpose instrument is always satisfactory for highly filtered beam intensities. - Highlights: • We compare the kVp estimate between CDTN instrument and 2 different kVp meters. • The new CDTN multipurpose instrument performance was found to be satisfactory. • All instruments increase kVp estimative for increasing additional filtration. • They are suitable for quality control routines in x-ray diagnostic radiology

  8. Progress in diagnostics of the COMPASS tokamak.

    Czech Academy of Sciences Publication Activity Database

    Weinzettl, Vladimír; Adámek, Jiří; Berta, Miklós; Bílková, Petra; Bogár, Ondrej; Böhm, Petr; Cavalier, Jordan; Dejarnac, Renaud; Dimitrova, Miglena; Ficker, Ondřej; Fridrich, David; Grover, Ondřej; Háček, Pavel; Havlíček, Josef; Havránek, Aleš; Horáček, Jan; Hron, Martin; Imríšek, Martin; Komm, Michael; Kovařík, Karel; Krbec, Jaroslav; Markovič, Tomáš; Matveeva, Ekaterina; Mitošinková, Klára; Mlynář, Jan; Naydenkova, Diana; Pánek, Radomír; Papřok, Richard; Peterka, Matěj; Podolník, Aleš; Seidl, Jakub; Šos, Miroslav; Stöckel, Jan; Tomeš, Matěj; Varavin, Mykyta; Varju, Jozef; Vlainic, Milos; Vondráček, Petr; Zajac, Jaromír; Žáček, František; Stano, M.; Anda, G.; Dunai, D.; Krizsanóczi, T.; Refy, D.; Zoletnik, S.; Silva, A.; Gomes, R.; Pereira, T.; Popov, Tsv.; Sarychev, D.; Ermak, G.P.; Zebrowski, J.; Jakubowski, M.; Rabinski, M.; Malinowski, K.; Nanobashvili, S.; Spolaore, M.; Vianello, N.; Gauthier, E.; Gunn, J. P.; Devitre, A.

    2017-01-01

    Roč. 12, December (2017), č. článku C12015. ISSN 1748-0221. [European Conference on Plasma Diagnostics (ECPD2017)/2./. Bordeaux, 18.04.2017-21.04.2017] R&D Projects: GA MŠk(CZ) LM2015045; GA ČR(CZ) GA15-10723S; GA ČR(CZ) GA16-25074S; GA ČR(CZ) GA14-35260S Institutional support: RVO:61389021 Keywords : Detector design and construction technologies and materials * Nuclear instruments and methods for hot plasma diagnostics * Plasma diagnostics - interferometry,spectroscopy and imaging * Plasma diagnostics - probes Subject RIV: BL - Plasma and Gas Discharge Physics OBOR OECD: 2.11 Other engineering and technologies Impact factor: 1.220, year: 2016 http://iopscience.iop.org/article/10.1088/1748-0221/12/12/C12015/pdf

  9. Chinese Postgraduate Choices When Considering a UK Business and Management Programme

    Science.gov (United States)

    Manns, Yihan; Swift, Jonathan

    2016-01-01

    This research investigated Chinese students' decision making processes for enrolling on a postgraduate taught business and management programme in a UK university, based on structured interviews, followed by a survey of just over 450 respondents. The validity and reliability of the research instrument were assessed prior to issuing the survey.…

  10. Multinational Design Evaluation Programme. Annual Report - April 2014-April 2015

    International Nuclear Information System (INIS)

    2015-06-01

    The Multinational Design Evaluation Programme (MDEP) is a multinational initiative to leverage the resources and knowledge of national regulatory authorities who are, or will shortly be, undertaking the review of new reactor power plant designs. MDEP incorporates a broad range of activities including enhancing multilateral co-operation within existing regulatory frameworks, and increasing multinational convergence of codes, standards, guides and safety goals. A key concept throughout the work of MDEP is that national regulators retain sovereign authority for all licensing and regulatory decisions. Working groups are implementing the activities in accordance with programme plans with specific activities and goals, and have established the necessary interfaces both within and outside of MDEP. This report provides a status of the programme after its seventh year of implementation. Content: Executive summary; 1. Introduction; 2. Programme goals and outcomes; 3. Programme implementation (Membership, Organisational structure, MDEP Library, Common positions); 4. Interactions with other organisations; 5. Current activities (EPR Working Group (EPRWG), AP1000 Working Group (AP1000WG), APR1400 Working Group (APR1400WG), VVER Working Group (VVERWG), AVBWR Working Group (ABWRWG), Vendor Inspection Co-operation Working Group (VICWG), Codes and Standards Working Group (CSWG), Digital Instrumentation and Controls Working Group (DICWG)); 6. Interim results; 7. Next steps - Future of the programme; Appendix 1 - List of abbreviations and acronyms; Appendix 2 - Revised documents and publications; Appendix 3 - Photographs of reactors considered within MDEP

  11. Ultrasound Instrumentation for Beam Diagnostics and Accelerating Structures Control

    CERN Document Server

    Moiseev, V I

    2005-01-01

    Sensitive elements and electronics for ultrasound measurements at conducting walls of beam pipes and accelerating structures are described. Noise protected instrumentation provides ultrasound spectra analysis in a wide frequency range up to 5 MHz.In circular accelerators, ultrasound fields in conducting walls of beam pipe represent the space-time characteristics of circulating beams. In accelerating structures, real high power operation modes of structure can be studied by outer ultrasound monitors. The experimental results at KSRS accelerators are discussed.

  12. Virtual vitreoretinal surgery: validation of a training programme.

    Science.gov (United States)

    Vergmann, Anna Stage; Vestergaard, Anders Højslet; Grauslund, Jakob

    2017-02-01

    To test the validity of the eyesi surgical simulator as an assessment tool in a virtual reality vitreoretinal training programme. In collaboration with an experienced vitreoretinal surgeon, a virtual vitreoretinal training programme was composed on the eyesi surgical simulator, software version 2.9.2 (VRmagic GmbH, Manheim, Germany). It was completed twice by three groups: 20 medical students, ten residents of ophthalmology and five trained vitreoretinal surgeons. The programme contained six training modules: navigation level 2 (Nav2), forceps training level 5 (ForT5), bimanual training level 3 (BimT3), laser coagulation level 3 (LasC3), posterior hyaloid level 3 (PostH3) and internal limiting membrane peeling level 3 (ILMP3). The scores in each module were assessed from two to five different factors (tissue treatment, efficiency, target achievement, instrument handling and microscope handling), and it was possible to achieve 100 points in each module. At the final training session, the highest overall median score was found for the vitreoretinal surgeons (vitreoretinal surgeons: 434 points, residents: 394.5 points, medical students: 272.5 points, p training programme with validity for the eyesi surgical simulator as an assessment tool for overall score and for four of six vitreoretinal modules. These findings could potentially make the programme a useful tool in the training of future vitreoretinal surgeons. © 2016 Acta Ophthalmologica Scandinavica Foundation. Published by John Wiley & Sons Ltd.

  13. Ion diode diagnostics to resolve beam quality issues

    Energy Technology Data Exchange (ETDEWEB)

    Bluhm, H; Buth, L; Hoppe, P [Forschungszentrum Karlsruhe (Germany). Institut fuer Neutronenphysik und Reaktortechnik; and others

    1997-12-31

    Various diagnostic methods and instruments are under development at the Forschungszentrum Karlsruhe to measure important physical quantities in the accelerating gap of high power diodes on KALIF with a high spatial and temporal resolution. The methods include optical spectroscopy, refractive index measurements, dispersion interferometry, and high resolution energy analysis. The setup of these diagnostic tools and the first results obtained for applied and self-magnetically insulated diodes are presented. (author). 6 figs., 5 refs.

  14. Evaluating disease management programme effectiveness: an introduction to the regression discontinuity design.

    Science.gov (United States)

    Linden, Ariel; Adams, John L; Roberts, Nancy

    2006-04-01

    Although disease management (DM) has been in existence for over a decade, there is still much uncertainty as to its effectiveness in improving health status and reducing medical cost. The main reason is that most programme evaluations typically follow weak observational study designs that are subject to bias, most notably selection bias and regression to the mean. The regression discontinuity (RD) design may be the best alternative to randomized studies for evaluating DM programme effectiveness. The most crucial element of the RD design is its use of a 'cut-off' score on a pre-test measure to determine assignment to intervention or control. A valuable feature of this technique is that the pre-test measure does not have to be the same as the outcome measure, thus maximizing the programme's ability to use research-based practice guidelines, survey instruments and other tools to identify those individuals in greatest need of the programme intervention. Similarly, the cut-off score can be based on clinical understanding of the disease process, empirically derived, or resource-based. In the RD design, programme effectiveness is determined by a change in the pre-post relationship at the cut-off point. While the RD design is uniquely suitable for DM programme evaluation, its success will depend, in large part, on fundamental changes being made in the way DM programmes identify and assign individuals to the programme intervention.

  15. Factors associated with malaria microscopy diagnostic performance following a pilot quality-assurance programme in health facilities in malaria low-transmission areas of Kenya, 2014.

    Science.gov (United States)

    Odhiambo, Fredrick; Buff, Ann M; Moranga, Collins; Moseti, Caroline M; Wesongah, Jesca Okwara; Lowther, Sara A; Arvelo, Wences; Galgalo, Tura; Achia, Thomas O; Roka, Zeinab G; Boru, Waqo; Chepkurui, Lily; Ogutu, Bernhards; Wanja, Elizabeth

    2017-09-13

    Malaria accounts for ~21% of outpatient visits annually in Kenya; prompt and accurate malaria diagnosis is critical to ensure proper treatment. In 2013, formal malaria microscopy refresher training for microscopists and a pilot quality-assurance (QA) programme for malaria diagnostics were independently implemented to improve malaria microscopy diagnosis in malaria low-transmission areas of Kenya. A study was conducted to identify factors associated with malaria microscopy performance in the same areas. From March to April 2014, a cross-sectional survey was conducted in 42 public health facilities; 21 were QA-pilot facilities. In each facility, 18 malaria thick blood slides archived during January-February 2014 were selected by simple random sampling. Each malaria slide was re-examined by two expert microscopists masked to health-facility results. Expert results were used as the reference for microscopy performance measures. Logistic regression with specific random effects modelling was performed to identify factors associated with accurate malaria microscopy diagnosis. Of 756 malaria slides collected, 204 (27%) were read as positive by health-facility microscopists and 103 (14%) as positive by experts. Overall, 93% of slide results from QA-pilot facilities were concordant with expert reference compared to 77% in non-QA pilot facilities (p malaria diagnosis. Microscopists who had recently completed refresher training and worked in a QA-pilot facility performed the best overall. The QA programme and formal microscopy refresher training should be systematically implemented together to improve parasitological diagnosis of malaria by microscopy in Kenya.

  16. The compatibility of flexible instruments under the Kyoto Protocol

    International Nuclear Information System (INIS)

    Jepma, C.J.; Van der Gaast, W.P.; Woerdman, E.

    1998-01-01

    The compatibility of the Kyoto Protocol flexible instruments and the lessons that can be learned form the AIJ-phase (AIJ stands for Activities Implemented Jointly) are discussed. The key point to be made is that there may be various applications of flexible instruments which can create situations where the various instruments would crowd out each other. On the other hand, applying flexible instruments may create a leverage for Parties in terms of achieving domestic environmental objectives. In addition, several issues related to the implementation of Joint Implementation (JI) , Clean Development Mechanism (CDM) and international emissions trading are discussed. The issues concern mainly those that have been included in the working programme on flexible instruments for CoP4 and CoP5 (CoP stands for Convention of Parties). As such the report discusses the consequences of possible negotiations outcomes at CoP for the effectiveness of flexible instruments, Parties' capabilities to achieve their Kyoto Protocol commitments cost-effectively, and the role of the private sector on the national and international credits markets(s). 106 refs

  17. Programmable pulse and analog data logger for environmental monitoring

    International Nuclear Information System (INIS)

    Winkler, R.; Hoetzl, H.

    1983-01-01

    A programmable data logger with 16 analog channels and 8 pulse channels is described to which nuclear radiation detectors, meteorological measuring instruments and transducers were connected for registration of operating data in the course of a research project in which natural and man-made radionuclide concentrations were measured near the ground. The set-up can be modified for other measuring and monitoring tasks. (orig.) [de

  18. Instrument development in support of Falcon and Phebus-FP

    International Nuclear Information System (INIS)

    Bowsher, B.R.; Brunning, J.

    1992-12-01

    This review has been undertaken to identify various on-line instruments and post-test analytical techniques that may improve the quality of data from both the Falcon Integral Test Programme and Phebus-FP. Particular emphasis is placed on the use of in-situ techniques to provide mass-based data on the aerodynamic properties of the aerosol and fission product-surface interactions. The principles of the following techniques are reviewed: cascade impactors, tapered element oscillating microbalance, condensation nucleus counter, Knudsen cell mass spectrometry, diffuse reflectance infrared Fourier transform spectrometry and secondary-ion mass spectrometry. These methods are currently being used in the Falcon experimental programme. (author)

  19. The impact of a leadership development programme on nurses' self-perceived leadership capability.

    Science.gov (United States)

    Paterson, Karyn; Henderson, Amanda; Burmeister, Elizabeth

    2015-11-01

    This paper reports on the outcomes of a locally designed educational programme to support leadership capability of junior registered nurses. The Developing Leader Programme is an in-house programme delivered in three face-to-face workshops, comprising self-directed reflective and application activities. Surveys were used to evaluate self-perceived leadership capability over a 9-month period. The survey comprised a Leadership Capability Instrument adapted from two existing tools. Participants completed surveys at the commencement of the programme, after the third and final workshop and approximately 6 months afterwards. In addition, examples of descriptive accounts of programme activities submitted by individual participants were included to enrich data. Of 124 participants, 79 completed surveys at the first workshop, 28 at the final workshop and 31 were returned 6 months after completion of the programme. Mean scores for each area of leadership capability significantly improved throughout the duration of the programme (P leadership behaviours through reported activities. Survey responses indicated that participants perceived improved leadership capability after completing the Developing Leader Programme. Early educational intervention to facilitate the development of leadership skills as well as clinical skills in junior registered nurses can assist with how they interact with the team. Participation of junior registered nurses in a locally designed leadership programme can assist them to develop leadership behaviours for everyday practice. © 2014 John Wiley & Sons Ltd.

  20. Joint investigation of working conditions, environmental and system performance at recycling centres--development of instruments and their usage.

    Science.gov (United States)

    Engkvist, I-L; Eklund, J; Krook, J; Björkman, M; Sundin, E; Svensson, R; Eklund, M

    2010-05-01

    Recycling is a new and developing industry, which has only been researched to a limited extent. This article describes the development and use of instruments for data collection within a multidisciplinary research programme "Recycling centres in Sweden - working conditions, environmental and system performance". The overall purpose of the programme was to form a basis for improving the function of recycling centres with respect to these three perspectives and the disciplines of: ergonomics, safety, external environment, and production systems. A total of 10 instruments were developed for collecting data from employees, managers and visitors at recycling centres, including one instrument for observing visitors. Validation tests were performed in several steps. This, along with the quality of the collected data, and experience from the data collection, showed that the instruments and methodology used were valid and suitable for their purpose. Copyright (c) 2009 Elsevier Ltd. All rights reserved.

  1. Evaluating the level of degree programmes in higher education: The case of nursing

    NARCIS (Netherlands)

    Rexwinkel, G.B.; Haenen, J.P.P.; Pilot, A.

    2013-01-01

    The European Quality Assurance system demands that the degree programme level is represented in terms of quantitative outcomes to be valid and reliable. To meet this need the Educational Level Evaluator (ELE) was devised. This conceptually designed procedure with instrumentation aiming to evaluate

  2. National Programme for Radiological Protection in Medical Exposures

    International Nuclear Information System (INIS)

    2013-07-01

    A national programme on radiation protection of patients can only be effective and sustainable if there is a joint effort between the regulatory body and the health authorities, and a cooperation with educational institutions, professional bodies and representatives of the industry. The regulatory body needs to promote a strategy of cooperation, and to identify obstacles that may prevent compliance with regulatory requirements and to address them. Not of least is the need for a continuous self-evaluation on the efficacy of the programme. Radiation safety of the patients is a responsibility of the users of the radiation sources involved in diagnostic and treatment. In particular, they are responsible for compliance with regulatory requirements. But safety depends also on aspects that are beyond the capabilities of those authorized to conduct practices. These aspects include educational programmes and institutions to implement them, calibration facilities, national protocols, professional bodies for the establishment of reference levels and contributions from the industry. Neither the users nor the regulatory body alone can achieve that these elements are in place. It needs a network of institutions and cooperation arrangements that involve educational and health authorities, laboratory facilities, professional bodies and the industry. A national programme has to include a strategy of cooperation, identification of obstacles that may prevent compliance with regulatory requirements and address them. Not of least is the need for a continuous self-evaluation on the efficacy of the programme. A group of regulatory agencies belonging to the Ibero American Forum of Nuclear and Radiation Regulatory Agency have exchanged experiences, lessons learned and good practices over three years. This exchange included extensive collaboration with the health authorities. The result of this work is this document containing a self-evaluation approach for the regulatory programme on

  3. SNS Diagnostics

    International Nuclear Information System (INIS)

    Shea, T.J.; Cameron, P.; Doolittle, L.; Power, J.

    2000-01-01

    The Spallation Neutron Source (SNS) Project is a collaborative effort to build the next generation neutron science facility at Oak Ridge, TN. The facility will deliver a 2 MW proton beam to a liquid mercury target. Neutrons from this target will be moderated and sent to several state-of-the-art instruments. Six national laboratories are involved in SNS construction. Berkeley (LBNL) will build the front end that produces a 2.5 MeV, 52 mA H-beam. Los Alamos (LANL) is responsible for the 1 GeV linac with a superconducting section provided by Thomas Jefferson (JLab). Brookhaven (BNL) is building the transfer lines and accumulator ring. Oak Ridge (ORNL) and Argonne (ANL) have responsibility for the target and instruments. All activities are coordinated by the SNS project office at Oak Ridge. The high beam power, a desired availability of 95%, and an aggressive commissioning schedule lead to some interesting challenges in beam diagnostics

  4. PLC and DTAM Software Programs for Pumping Instrumentation and Control Skid M

    Energy Technology Data Exchange (ETDEWEB)

    KOCH, M.R.

    2000-02-14

    This document describes the software programs for the Programmable Logic Controller and the Data Table Access Module for Pumping Instrumentation and Control skid ''M''. The Appendices contains copies of the printouts of these software programs.

  5. Comparison of conventional Papanicolaou smear and SurePath® liquid-based cytology in the Copenhagen population screening programme for cervical cancer

    DEFF Research Database (Denmark)

    Kirschner, Benny; Simonsen, Kåre; Junge, Jette

    2006-01-01

    OBJECTIVE: To compare diagnostic performance of conventional Papanicolaou smear with SurePath liquid-based cytology in a population screening programme. METHODS: A retrospective comparison was performed on data from two 18-month periods of the screening programme for cervical cancer in the munici......OBJECTIVE: To compare diagnostic performance of conventional Papanicolaou smear with SurePath liquid-based cytology in a population screening programme. METHODS: A retrospective comparison was performed on data from two 18-month periods of the screening programme for cervical cancer...... in the municipality of Copenhagen with conventional Papanicolaou technique (n = 82,116) and liquid-based cytology (n = 84,414). RESULTS: After the conversion to liquid-based cytology the percentage of unsatisfactory samples decreased from 2.3% to 0.3% (P ...-based technique. CONCLUSIONS: This study showed the number of unsatisfactory samples to be significantly reduced with the liquid-based technique. The data suggest that there is an increased detection rate of cervical precancerous lesions with liquid-based cytology, but the number of false positive tests is still...

  6. Thai Grade 11 Students' Alternative Conceptions for Acid-Base Chemistry

    Science.gov (United States)

    Artdej, Romklao; Ratanaroutai, Thasaneeya; Coll, Richard Kevin; Thongpanchang, Tienthong

    2010-01-01

    This study involved the development of a two-tier diagnostic instrument to assess Thai high school students' understanding of acid-base chemistry. The acid-base diagnostic test (ABDT) comprising 18 items was administered to 55 Grade 11 students in a science and mathematics programme during the second semester of the 2008 academic year. Analysis of…

  7. Australian Primary Students' Motivation and Learning Intentions for Extra-Curricular Music Programmes

    Science.gov (United States)

    Ng, Clarence

    2017-01-01

    What are the motivational differences between students who intend to continue their learning in instrumental and choral music programmes and those who intend to discontinue? Using an achievement-goal perspective, this study investigated motivation and learning intentions of Australian students who had engaged in these extra-curricular music…

  8. Diagnostic development and support of MHD test facilities: Technical progress report for the period January, February, March 1985

    International Nuclear Information System (INIS)

    Shepard, W.S.; Cook, R.L.

    1985-04-01

    Mississippi State University is developing diagnostic instruments for MHD power train data acquisition and for support of MHD component development test facilities. Microprocessor-controlled optical instruments, initially developed for HRSR support, are being refined, and new systems to measure temperatures and gas-seed-slag stream characteristics are being developed. To further data acquisition and analysis capabilities, the diagnostic systems are being interfaced with MHD Energy Center computers. Additionally, technical support of the diagnostic needs of the national MHD research effort is being provided

  9. Overview of the data acquisition and control system for plasma diagnostics on MFTF-B

    International Nuclear Information System (INIS)

    Wyman, R.H.; Deadrick, F.J.; Lau, N.H.; Nelson, B.C.; Preckshot, G.G.; Throop, A.L.

    1983-01-01

    For MFTF-B, the plasma diagnostics system is expected to grow from a collection of 12 types of diagnostic instruments, initially producing about 1 Megabyte of data per shot, to an expanded set of 22 diagnostics producing about 8 Megabytes of data per shot. To control these diagnostics and acquire and process the data, a system design has been developed which uses an architecture similar to the supervisory/local-control computer system which is used to control other MFTF-B subsystems. This paper presents an overview of the hardware and software that will control and acquire data from the plasma diagnostics system. Data flow paths from the instruments, through processing, and into final archived storage will be described. A discussion of anticipated data rates, including anticipated software overhead at various points of the system, is included, along with the identification of possible bottlenecks. A methodology for processing of the data is described, along with the approach to handle the planned growth in the diagnostic system. Motivations are presented for various design choices which have been made

  10. Experience with instrumentational monitoring of steam turbine foundations

    International Nuclear Information System (INIS)

    Linnemann, H.; Hagemann, M.

    1989-01-01

    Many factors can lead to the deformation of foundations and consequently to variations in the state of alignment of a turbine shaft line. Various measurement programmes, measurement procedures and instrumentation have been developed and proven in power plant practice. Experience accumulated hitherto with automatic measurement systems shows that these procedures are superior to conventional methods in respect of accuracy, availability and information content. (orig.) [de

  11. Preliminary evaluation of the impact of a Web-based HIV testing programme in Abruzzo Region on the prevention of late HIV presentation and associated mortality.

    Science.gov (United States)

    Polilli, Ennio; Sozio, Federica; Di Stefano, Paola; Clerico, Luigi; Di Iorio, Giancarlo; Parruti, Giustino

    2018-04-01

    This study aimed to analyze the efficacy of a Web-based testing programme in terms of the prevention of late HIV presentation. The clinical characteristics of patients diagnosed with HIV via the Web-based testing programme were compared to those of patients diagnosed in parallel via standard diagnostic care procedures. This study included the clinical and demographic data of newly diagnosed HIV patients enrolled at the study clinic between February 2014 and June 2017. These patients were diagnosed either via standard diagnostic procedures or as a result of the Web-based testing programme. Eighty-eight new cases of HIV were consecutively enrolled; their mean age was 39.1±13.0 years. Fifty-nine patients (67%) were diagnosed through standard diagnostic procedures and 29 (33%) patients came from the Web-based testing programme. Late presentation (62% vs. 34%, p=0.01) and AIDS-defining conditions at presentation (13 vs. 1, p=0.02) were significantly more frequent in the standard care group than in the Web-based group; four of 13 patients with AIDS diagnosed under standard diagnostic procedures died, versus none in the Web-based testing group (pWeb-based recruitment for voluntary and free HIV testing helped to diagnose patients with less advanced HIV disease and no risk of death, from all at-risk groups, in comparison with standard care testing. Copyright © 2018 The Authors. Published by Elsevier Ltd.. All rights reserved.

  12. Nuclear instrumentation for uranium exploration

    International Nuclear Information System (INIS)

    Sarma, Ch. V.N.; Sarma, C.V.R.; Sreehari, R.

    1999-01-01

    Instrumentation required for uranium exploration may be broadly classified based on surface and sub-surface measurement of gamma-ray intensity. Surface measurement of gross and spectral gamma intensity are carried out by employing portable Geiger Mueller/scintillation counters and four-channel spectrometers. Measurement of thoron ( 220 Rn) and radon ( 222 Rn) in the soil gas is being carried out by closed circuit technique using radon measuring system. Radiometric mapping of trenches, pits and mine-faces are carried out using shielded probe with 2π source geometry, whereas logging sonde with instruments through the steel armoured cable are employed for point to 4π geometry. Spectral borehole logging system with built-in multi-channel analyser (MCA) has been developed for the uranium exploration programme for AMD. Note-book PC based high sensitivity air-borne gamma-ray spectrometric survey system has been designed, developed and test flown. (author)

  13. Diagnostic Devices for Isothermal Nucleic Acid Amplification

    Directory of Open Access Journals (Sweden)

    Chia-Chen Chang

    2012-06-01

    Full Text Available Since the development of the polymerase chain reaction (PCR technique, genomic information has been retrievable from lesser amounts of DNA than previously possible. PCR-based amplifications require high-precision instruments to perform temperature cycling reactions; further, they are cumbersome for routine clinical use. However, the use of isothermal approaches can eliminate many complications associated with thermocycling. The application of diagnostic devices for isothermal DNA amplification has recently been studied extensively. In this paper, we describe the basic concepts of several isothermal amplification approaches and review recent progress in diagnostic device development.

  14. Diagnostic devices for isothermal nucleic acid amplification.

    Science.gov (United States)

    Chang, Chia-Chen; Chen, Chien-Cheng; Wei, Shih-Chung; Lu, Hui-Hsin; Liang, Yang-Hung; Lin, Chii-Wann

    2012-01-01

    Since the development of the polymerase chain reaction (PCR) technique, genomic information has been retrievable from lesser amounts of DNA than previously possible. PCR-based amplifications require high-precision instruments to perform temperature cycling reactions; further, they are cumbersome for routine clinical use. However, the use of isothermal approaches can eliminate many complications associated with thermocycling. The application of diagnostic devices for isothermal DNA amplification has recently been studied extensively. In this paper, we describe the basic concepts of several isothermal amplification approaches and review recent progress in diagnostic device development.

  15. R+D programme 'Environmental engineering'. R+D projects 1994. Data of September 1, 1994

    International Nuclear Information System (INIS)

    1994-01-01

    Research programmes of the Federal Republic of Germany in the field of environmental engineering are presented. Research is done in the fields of low-emission production processes, environmentally acceptable materials and products, and environmental analysis and measuring instruments. (SR) [de

  16. Instruments for the assessment of suicide risk: A systematic review evaluating the certainty of the evidence.

    Directory of Open Access Journals (Sweden)

    Bo Runeson

    Full Text Available Instruments have been developed to facilitate suicide risk assessment. We aimed to evaluate the evidence for these instruments including assessment of risk of bias and diagnostic accuracy for suicide and suicide attempt.PubMed (NLM, PsycInfo, Embase, Cinahl and the Cochrane Library databases were searched until December 2014. We assessed risk of bias with QUADAS-2. The average sensitivity and specificity of each instrument was estimated and the certainty of the evidence was assessed with GRADE. We considered instruments with a sensitivity > 80% and a specificity > 50% to have sufficient diagnostic accuracy.Thirty-five relevant studies were identified but 14 were considered to have high risk of bias, leaving 21 studies evaluating altogether 15 risk assessment instruments. We could carry out meta-analyses for five instruments. For the outcome suicide attempt SAD PERSONS Scale had a sensitivity of 15% (95% CI 8-24 and specificity of 97% (96-98, and the Manchester Self-Harm Rule (MSHR a sensitivity of 97% (97-97 and a specificity of 20% (20-21. ReACT, which is a modification of MSHR, had a similar low specificity, as did the Sodersjukhuset Self Harm Rule. For the outcome suicide, the Beck Hopelessness Scale had a sensitivity of 89% (78-95 and specificity of 42% (40-43.Most suicide risk assessment instruments were supported by too few studies to allow for evaluation of accuracy. Among those that could be evaluated, none fulfilled requirements for sufficient diagnostic accuracy.

  17. Assessment Stability and Informative of Diagnostic Matrix in Analysis States of Reinforced Concrete Slab

    Directory of Open Access Journals (Sweden)

    Sokolov Vladimir

    2016-01-01

    Full Text Available In this article was examined the issues of sustainability and informative of diagnostic matrix, which are used when it is necessary to determinate the technical condition of constructions. Determination based on the mathematical instrument of technical diagnostics. One of the most widespread methods of technical diagnostics – a statistical method of Bayes is used.

  18. Multinational design evaluation programme. Annual Report April 2015-April 2016

    International Nuclear Information System (INIS)

    2016-05-01

    The Multinational Design Evaluation Programme (MDEP) is a multinational initiative to leverage the resources and knowledge of national regulatory authorities that are, or will shortly be, undertaking the review of new reactor power plant designs. MDEP incorporates a broad range of activities including enhancing multilateral co-operation within existing regulatory frameworks, and increasing multinational convergence of codes, standards, guides, and safety goals. A key concept throughout the work of MDEP is that national regulators retain sovereign authority for all licensing and regulatory decisions. Working groups are implementing the activities in accordance with programme plans with specific activities and goals, and have established the necessary interfaces both within and outside of MDEP. This report provides a status of the programme after its eighth year of implementation. Content: Executive Summary; 1 - Introduction; 2 - Programme goals and outcomes; 3 - Programme implementation (Membership, Organizational structure, MDEP Library, Common positions); 4 - Interactions with other organizations; 5 - Current activities (EPR Working Group (EPRWG), AP1000 Working Group (AP1000WG), APR1400 Design-specific Working Group (APR1400WG), VVER Working Group (VVERWG), ABWR Working Group (ABWRWG), Vendor Inspection Co-operation Working Group (VICWG), Codes and Standards Working Group (CSWG), Digital Instrumentation and Controls Working Group (DICWG); 6 - Interim results; 7 - Next steps - future of the programme; appendix 1: List of abbreviations and acronyms; Appendix 2: Revised documents and publications; Appendix 3: Photographs of reactors considered within MDEP

  19. The Discriminative Ability and Diagnostic Utility of the ADOS-G, ADI-R, and GARS for Children in a Clinical Setting

    Science.gov (United States)

    Mazefsky, Carla A.; Oswald, Donald P.

    2006-01-01

    Recent years have seen a surge of interest in assessment instruments for diagnosing autism in children. Instruments have generally been developed and evaluated from a research perspective. The Autism Diagnostic Observation Schedule-Generic (ADOS-G), Autism Diagnostic Interview-Revised (ADI-R), and Gilliam Autism Rating Scale (GARS) have received…

  20. Integration of the ITER diagnostic plant systems with CODAC

    International Nuclear Information System (INIS)

    Simrock, S.; Barnsley, R.; Bertalot, L.; Hansalia, C.; Klotz, W.D.; Makijarvi, P.; Reichle, R.; Vayakis, G.; Yonekawa, I.; Walker, C.; Wallander, A.; Walsh, M.; Winter, A.

    2011-01-01

    ITER requires extensive diagnostic systems in order to meet the requirements for machine operation, protection, plasma control and physics studies. The realization of these systems is a major challenge not only because of the harsh environment and the nuclear requirements but also with respect to Instrumentation and Control (I and C) of all the 59 diagnostics plants. The Plant Systems I and C are mostly 'in-kind', i.e. procured by the seven ITER Domestic Agencies (DAs), while the Central I and C Systems are 'in-fund', i.e. procured by ITER Organization (IO). Standardization of Plant Systems I and C is of primary importance and has been one of the highest priority tasks of CODAC. The standards are published in the Plant Control Design Handbook (PCDH) which will be followed to ensure a homogeneous design, guarantee high availability and simplify maintenance and support future upgrades. Most important for a successful commissioning and operation of the ITER facility are the concepts of interfacing the diagnostics plant systems with CODAC and the standards for instrumentation and control which must be followed all contributing parties. In this paper, we will elaborate on the concepts of interfacing the diagnostics plant systems with CODAC and the standards that must be followed for the design.

  1. Status of the design of the ITER ECE diagnostic

    International Nuclear Information System (INIS)

    Taylor, G.; Austin, M. E.; Beno, J. H.; Danani, S.; Ellis, R. F.; Feder, R.; Hesler, J. L.; Hubbard, A. E.; Johnson, D. W.; Kumar, R.; Kumar, S.; Kumar, V.; Ouroua, A.; Pandya, H. K. B.; Phillips, P. E.; Roman, C.; Rowan, W. L.; Udintsev, V.; Vayakis, G.; Walsh, M.; Kubo, S.

    2015-01-01

    In this study, the baseline design for the ITER electron cyclotron emission (ECE) diagnostic has entered the detailed preliminary design phase. Two plasma views are planned, a radial view and an oblique view that is sensitive to distortions in the electron momentum distribution near the average thermal momentum. Both views provide high spatial resolution electron temperature profiles when the momentum distribution remains Maxwellian. The ECE diagnostic system consists of the front-end optics, including two 1000 K calibration sources, in equatorial port plug EP9, the 70-1000 GHz transmission system from the front-end to the diagnostics hall, and the ECE instrumentation in the diagnostics hall. The baseline ECE instrumentation will include two Michelson interferometers that can simultaneously measure ordinary and extraordinary mode ECE from 70 to 1000 GHz, and two heterodyne radiometer systems, covering 122-230 GHz and 244-355 GHz. Significant design challenges include 1) developing highly-reliable 1000 K calibration sources and the associated shutters/mirrors, 2) providing compliant couplings between the front-end optics and the polarization splitter box that accommodate displacements of the vacuum vessel during plasma operations and bake out, 3) protecting components from damage due to stray ECH radiation and other intense millimeter wave emission and 4) providing the low-loss broadband transmission system

  2. National NIF Diagnostic Program Interim Management Plan

    International Nuclear Information System (INIS)

    Warner, B

    2002-01-01

    The National Ignition Facility (NIF) has the mission of supporting Stockpile Stewardship and Basic Science research in high-energy-density plasmas. To execute those missions, the facility must provide diagnostic instrumentation capable of observing and resolving in time events and radiation emissions characteristic of the plasmas of interest. The diagnostic instrumentation must conform to high standards of operability and reliability within the NIF environment. These exacting standards, together with the facility mission of supporting a diverse user base, has led to the need for a central organization charged with delivering diagnostic capability to the NIF. The National NIF Diagnostics Program (NNDP) has been set up under the aegis of the NIF Director to provide that organization authority and accountability to the wide user community for NIF. The funds necessary to perform the work of developing diagnostics for NIF will be allocated from the National NIF Diagnostics Program to the participating laboratories and organizations. The participating laboratories and organizations will design, build, and commission the diagnostics for NIF. Restricted availability of funding has had an adverse impact, unforeseen at the time of the original decision to projectize NIF Core Diagnostics Systems and Cryogenic Target Handing Systems, on the planning and initiation of these efforts. The purpose of this document is to provide an interim project management plan describing the organizational structure and management processes currently in place for NIF Core Diagnostics Systems. Preparation of a Program Execution Plan for NIF Core Diagnostics Systems has been initiated and a current draft is provided as Attachment 1 to this document. The National NIF Diagnostics Program Interim Management Plan provides a summary of primary design criteria and functional requirements, current organizational structure, tracking and reporting procedures, and current planning estimates of project scope

  3. Radiochemistry Programme biennial progress report 1984 and 1985

    International Nuclear Information System (INIS)

    1986-01-01

    This biennial progress report of the Radiochemistry Programme covers the calendar years 1984 and 1985. This report is organised into sections in a manner similar to the organisation of the Radiochemistry Programme. Thus the section on Fuel Behaviour Studies include post-irradiation studies (where the emphasis has been on setting up of facilities), mass spectrometry an nuclear chemistry. Process Chemistry Section covers the activities relating to fuel reprocessing as well as preparation and characterisation of fuel materials. Solid State Chemistry Section deals with thermophysical properties, thermogravimetry, oxygen potentials etc. In the Sodium Chemistry Section the developments relating to on-line meters and their applications are stressed in addition to studies on ternary systems involving sodium and oxygen. Developments in analytical chemistry and analytical services are covered in the next two Sections. Technical Services Section deals with developments in instrumentation and mechanical fabrication. (author)

  4. Use of modern software - based instrumentation in safety critical systems

    International Nuclear Information System (INIS)

    Emmett, J.; Smith, B.

    2005-01-01

    Many Nuclear Power Plants are now ageing and in need of various degrees of refurbishment. Installed instrumentation usually uses out of date 'analogue' technology and is often no longer available in the market place. New technology instrumentation is generally un-qualified for nuclear use and specifically the new 'smart' technology contains 'firmware', (effectively 'soup' (Software of Uncertain Pedigree)) which must be assessed in accordance with relevant safety standards before it may be used in a safety application. Particular standards are IEC 61508 [1] and the British Energy (BE) PES (Programmable Electronic Systems) guidelines EPD/GEN/REP/0277/97. [2] This paper outlines a new instrument evaluation system, which has been developed in conjunction with the UK Nuclear Industry. The paper concludes with a discussion about on-line monitoring of Smart instrumentation in safety critical applications. (author)

  5. SLP - A single level Breit-Wigner cross-section generating programme

    International Nuclear Information System (INIS)

    Doherty, G.

    1965-06-01

    Unbroadened cross-sections are calculated from a single level Breit-Wigner approximation which allows for resonance-potential interference but not resonance-resonance interference. Doppler broadening, and instrumental resolution broadening for thin samples, are optionally performed by successive numerical convolutions. An energy point selection and discard system enables the cross-section over a specified energy range to be represented to a required degree of accuracy using the minimum number of energy points. An energy grid prepared by the user can be incorporated in the calculation but the programme will usually be more efficient if only the end points of the energy range of interest are specified by the user and the intermediate energy points left to the programme to organise. The capacity of the programme varies with the energy range and type of resonance (narrow or broad). About fifty resonances may be sufficient to generate an energy grid of 4000 energy points, which is the maximum allowable energy vector. The programme is written in KDF9 EGTRAN (a FORTRAN dialect); output is printed and may be copied on cards, and intermediate results are stored on magnetic disc. (author)

  6. The effect of educational intervention on the adoption of nickel-titanium rotary instrumentation in a Public Dental Service.

    Science.gov (United States)

    Reit, C; Bergenholtz, G; Caplan, D; Molander, A

    2007-04-01

    To study the influence of two educational programmes on the adoption of nickel-titanium rotary instrumentation (NTRI) amongst general dental practitioners in a short-term as well as a long-term perspective. All dentists employed in the Gothenburg Dental service (n = 148) were enrolled in the study. The clinics in the organization were randomly assigned to one of two educational programmes. In the first programme a 4-h lecture on root canal instrumentation was given. In the second programme the lecture course was supplemented by a 6-h hands-on training session. The short-term effect was measured by a questionnaire distributed 6 months after completed education. The long-term effect was evaluated 4 years later. The overall utilization rate of NTRI increased from 4% to 73%. However, lectures in combination with hands-on training resulted in a better short-term acceptance rate (94%) than if teaching was given only in lecture-format (53%) (P = 0.000). As a consequence, all staff were offered hands-on training. The long-term adoption rate was 88%. Reasons for accepting the new technology usually were found within the 'relative advantage' category. Common reasons for dentists not to adopt NTRI were that they could not get started or that they found no advantage over the old technology. The short-term adoption of a new technology might be influenced by the design of an introductory educational programme. For clinical procedures, such as root canal instrumentation, the inclusion of hands-on training sessions seems to be important to reach a high acceptance rate.

  7. Is the Eating Disorder Questionnaire-Online (EDQ-O) a valid diagnostic instrument for the DSM-IV-TR classification of eating disorders?

    Science.gov (United States)

    ter Huurne, Elke D; de Haan, Hein A; ten Napel-Schutz, Marieke C; Postel, Marloes G; Menting, Juliane; van der Palen, Job; Vroling, Maartje S; DeJong, Cor A J

    2015-02-01

    The Eating Disorder Questionnaire-Online (EDQ-O) is an online self-report questionnaire, which was developed specifically to provide a DSM-IV-TR classification of anorexia nervosa (AN), bulimia nervosa (BN), binge-eating disorder (BED), and eating disorder not otherwise specified (EDNOS), without using a face-to-face clinical interview. The purpose of the present study was to examine the psychometric quality of the EDQ-O. The validity of the EDQ-O was determined by examining the agreement with the diagnoses obtained from the Longitudinal, Expert, and All DATA (LEAD) standard. Participants included 134 new patients of a specialist center for eating disorders located in the Netherlands. Assessment of the validity of the EDQ-O yielded acceptable to good AUC (area under the receiver operating characteristic curve) values with a range from 0.72 to 0.83. Most other diagnostic efficiency statistics were also good except for a low sensitivity for AN (0.44), a low positive predictive value for BN (0.50), and a relatively low sensitivity for BED (0.66). The results of the present study suggest that the EDQ-O performs acceptably as a diagnostic instrument for all DSM-IV-TR eating disorder classifications. However, suggestions are made to further improve the validity of the EDQ-O. Copyright © 2014 Elsevier Inc. All rights reserved.

  8. Programmable Logic Controllers for Systems of Automatic of the Level Crossing

    Directory of Open Access Journals (Sweden)

    Mieczyslaw Kornaszewski

    2006-01-01

    Full Text Available The railway crossings are vulnerable to incidence of high number of accidents often deadly. In order to face this problem, the modern systems of automatic of the level crossing have been introduced. These systems are based on Programmable Logic Controllers, which allow the designers to exploit self-control mechanisms, events acquiring, technical diagnostic which in turn enable remote control and acquisition of faults.

  9. 21 CFR 892.1940 - Radiologic quality assurance instrument.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Radiologic quality assurance instrument. 892.1940 Section 892.1940 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES RADIOLOGY DEVICES Diagnostic Devices § 892.1940 Radiologic quality assurance...

  10. ITER diagnostics ex-vessel engineering services

    Energy Technology Data Exchange (ETDEWEB)

    Arumugam, A.P., E-mail: arun.prakash@iter.org; Walker, C.I.; Andrew, P.; Barnsley, R.; Beltran, D.; Bertalot, L.; Dammann, A.; Direz, M.F.; Drevon, J.M.; Encheva, A.; Giacomin, T.; Hourtoule, J.; Kuehn, I.; Lanza, R.; Levesy, B.; Maquet, P.; Patel, K.M.; Patisson, L.; Pitcher, C.S.; Portales, M.; and others

    2013-10-15

    Highlights: • This paper describes about the ITER diagnostics ex-vessel engineering services. • It describes various diagnostics systems, its location and its environment. • Diagnostics interfaces with other services such as the buildings, HVAC, electrical services, cooling water, vacuum, liquid and gas distribution. • All the interfaces with these services are identified and defined. • Buildings services for diagnostics, such as penetrations, local shielding, embedment and temperature control are discussed. -- Abstract: Extensive diagnostics systems will be installed on the ITER machine to provide the measurements necessary to control, evaluate and optimize plasma performance in ITER and to further the understanding of plasma physics. These include measurements of temperature, density, impurity concentration, and particle and energy confinement times. ITER diagnostic systems extend from the center of the Tokamak to the various diagnostic areas, where they are controlled and acquired data is processed. This mainly includes the areas such as ports, port cells, gallery, diagnostics enclosures and cubicle areas. The diagnostics port plugs encloses the front end of the diagnostic systems and the diagnostics building houses the diagnostics equipment, instrumentation and control cubicles. There are several systems providing services to diagnostics. These mainly include ITER buildings, electrical power services, cooling water services, Heating Ventilation and Air Conditioning (HVAC), vacuum services, liquid and gas distribution services, cable engineering, de-tritiation systems, control cubicles, etc. Requirements of these service systems have to be defined, even though many of the diagnostics are at an early stage of development. It is a real challenge to define and to design diagnostics systems considering the constraints imposed by these service systems. This paper summarizes the provision of these services to the individual diagnostics and diagnostics areas

  11. ITER diagnostics ex-vessel engineering services

    International Nuclear Information System (INIS)

    Arumugam, A.P.; Walker, C.I.; Andrew, P.; Barnsley, R.; Beltran, D.; Bertalot, L.; Dammann, A.; Direz, M.F.; Drevon, J.M.; Encheva, A.; Giacomin, T.; Hourtoule, J.; Kuehn, I.; Lanza, R.; Levesy, B.; Maquet, P.; Patel, K.M.; Patisson, L.; Pitcher, C.S.; Portales, M.

    2013-01-01

    Highlights: • This paper describes about the ITER diagnostics ex-vessel engineering services. • It describes various diagnostics systems, its location and its environment. • Diagnostics interfaces with other services such as the buildings, HVAC, electrical services, cooling water, vacuum, liquid and gas distribution. • All the interfaces with these services are identified and defined. • Buildings services for diagnostics, such as penetrations, local shielding, embedment and temperature control are discussed. -- Abstract: Extensive diagnostics systems will be installed on the ITER machine to provide the measurements necessary to control, evaluate and optimize plasma performance in ITER and to further the understanding of plasma physics. These include measurements of temperature, density, impurity concentration, and particle and energy confinement times. ITER diagnostic systems extend from the center of the Tokamak to the various diagnostic areas, where they are controlled and acquired data is processed. This mainly includes the areas such as ports, port cells, gallery, diagnostics enclosures and cubicle areas. The diagnostics port plugs encloses the front end of the diagnostic systems and the diagnostics building houses the diagnostics equipment, instrumentation and control cubicles. There are several systems providing services to diagnostics. These mainly include ITER buildings, electrical power services, cooling water services, Heating Ventilation and Air Conditioning (HVAC), vacuum services, liquid and gas distribution services, cable engineering, de-tritiation systems, control cubicles, etc. Requirements of these service systems have to be defined, even though many of the diagnostics are at an early stage of development. It is a real challenge to define and to design diagnostics systems considering the constraints imposed by these service systems. This paper summarizes the provision of these services to the individual diagnostics and diagnostics areas

  12. Assessment of the Diagnostic Potential of Clinotech TB Screen Test ...

    African Journals Online (AJOL)

    The Clinotech TB Screen test, a 3rd generation multi-antigen rapid chromatographic immunoassay for detection of IgG antibodies in serum against recombinant protein antigens 38kDa, 16kDa and 6kDa, was assessed for its diagnostic potential for diagnosis of active pulmonary TB in routine TB control programme in Abia ...

  13. Recent developments in the field of nuclear power plant control and instrumentation in Hungary

    International Nuclear Information System (INIS)

    Pellionisz, P.

    1992-01-01

    A considerable percentage (32.8% in 1989) of electric energy in Hungary is produced by nuclear power plant Paks. The paper presents an overview of activities on control and instrumentation in the following areas: Control and instrumentation upgrading; training simulators; diagnostic systems. (author). 1 tab

  14. MECs: "Building Blocks" for Creating Biological and Chemical Instruments.

    Directory of Open Access Journals (Sweden)

    Douglas A Hill

    Full Text Available The development of new biological and chemical instruments for research and diagnostic applications is often slowed by the cost, specialization, and custom nature of these instruments. New instruments are built from components that are drawn from a host of different disciplines and not designed to integrate together, and once built, an instrument typically performs a limited number of tasks and cannot be easily adapted for new applications. Consequently, the process of inventing new instruments is very inefficient, especially for researchers or clinicians in resource-limited settings. To improve this situation, we propose that a family of standardized multidisciplinary components is needed, a set of "building blocks" that perform a wide array of different tasks and are designed to integrate together. Using these components, scientists, engineers, and clinicians would be able to build custom instruments for their own unique needs quickly and easily. In this work we present the foundation of this set of components, a system we call Multifluidic Evolutionary Components (MECs. "Multifluidic" conveys the wide range of fluid volumes MECs operate upon (from nanoliters to milliliters and beyond; "multi" also reflects the multiple disciplines supported by the system (not only fluidics but also electronics, optics, and mechanics. "Evolutionary" refers to the design principles that enable the library of MEC parts to easily grow and adapt to new applications. Each MEC "building block" performs a fundamental function that is commonly found in biological or chemical instruments, functions like valving, pumping, mixing, controlling, and sensing. Each MEC also has a unique symbol linked to a physical definition, which enables instruments to be designed rapidly and efficiently using schematics. As a proof-of-concept, we use MECs to build a variety of instruments, including a fluidic routing and mixing system capable of manipulating fluid volumes over five orders

  15. Communication between nurses and simulated patients with cancer: evaluation of a communication training programme.

    NARCIS (Netherlands)

    Kruijver, I.P.M.; Kerkstra, A.; Kerssens, J.J.; Holtkamp, C.C.M.; Bensing, J.M.; Wiel, H.B.M. van de

    2001-01-01

    In this paper the effect of a communication training programme on the instrumental and affective communication skills employed by ward nurses during the admittance interview with recently diagnosed cancer patients was investigated. The training focused on teaching nurses skills to discuss and handle

  16. Development of multifunctional radiation monitoring instrument based on PLC technology

    International Nuclear Information System (INIS)

    Li Ziqiang; Zhu Yuye; Zhuang Min

    2007-01-01

    This eight-channel multifunctional Radiation Monitoring Instrument is developed by making use of the built-in high-speed counters and the powerful instruction system of the SIEMES SIMATICS S7 series Programmable Logic Controllers (PLC) to record and process the pulse signal output by the detectors. The instrument with functions, such as analog and digital display, digital storage of digital data, pulse signal generator, network communication, can connect various types of pulse detectors. The initial process can be translated between Graduation Apparatus method and Formula method. the logicality of the high-dosage warning system is processed itself. The signal output will drive the alarm lights and bell directly. This paper mainly describes the configuration, programming and feature of the instrument. (authors)

  17. Point-of-care technologies for molecular diagnostics using a drop of blood.

    Science.gov (United States)

    Song, Yujun; Huang, Yu-Yen; Liu, Xuewu; Zhang, Xiaojing; Ferrari, Mauro; Qin, Lidong

    2014-03-01

    Molecular diagnostics is crucial for prevention, identification, and treatment of disease. Traditional technologies for molecular diagnostics using blood are limited to laboratory use because they rely on sample purification and sophisticated instruments, are labor and time intensive, expensive, and require highly trained operators. This review discusses the frontiers of point-of-care (POC) diagnostic technologies using a drop of blood obtained from a finger prick. These technologies, including emerging biotechnologies, nanotechnologies, and microfluidics, hold the potential for rapid, accurate, and inexpensive disease diagnostics. Copyright © 2014 Elsevier Ltd. All rights reserved.

  18. PROGRAMMABLE METRONOME FOR PERCUSSION INSTRUMENTS AND AN APPLICATION

    Directory of Open Access Journals (Sweden)

    Hasan Selçuk Selek

    2012-01-01

    Full Text Available Applications of electronics in the music industry have been increasing continuosly. Develpoments in electro music and electro music instruments make this possible. Although it is known that the majority of musicians are against the digital music and techniques, researches show that it would be very benefical for teaching and learning of playing music intruments. This study shows that, music and electronic applications can be useable with together in the same projects. With this equipment people can practice on their own percussion studies. System designed as, speed and hit force in case of faulty users can be warned by program. Warning can be reailized as a visual with LED and also can be done with sound. In this study, at the same time shows that, without using physical metronome, metronome software and designed card can use at applications is may be possible. Based on the study is a software metronome and its card which can be used for all musical intruments. Designed metronome was tested for a electronic drum with a compare circuit. PIC-C compiler was used in order to get the designed card to work compatible with PIC. The circuit designed for the metronome is integrated with compare circuit and has been tested together.

  19. Progress in diagnostics of the COMPASS tokamak

    Science.gov (United States)

    Weinzettl, V.; Adamek, J.; Berta, M.; Bilkova, P.; Bogar, O.; Bohm, P.; Cavalier, J.; Dejarnac, R.; Dimitrova, M.; Ficker, O.; Fridrich, D.; Grover, O.; Hacek, P.; Havlicek, J.; Havranek, A.; Horacek, J.; Hron, M.; Imrisek, M.; Komm, M.; Kovarik, K.; Krbec, J.; Markovic, T.; Matveeva, E.; Mitosinkova, K.; Mlynar, J.; Naydenkova, D.; Panek, R.; Paprok, R.; Peterka, M.; Podolnik, A.; Seidl, J.; Sos, M.; Stockel, J.; Tomes, M.; Varavin, M.; Varju, J.; Vlainic, M.; Vondracek, P.; Zajac, J.; Zacek, F.; Stano, M.; Anda, G.; Dunai, D.; Krizsanoczi, T.; Refy, D.; Zoletnik, S.; Silva, A.; Gomes, R.; Pereira, T.; Popov, Tsv.; Sarychev, D.; Ermak, G. P.; Zebrowski, J.; Jakubowski, M.; Rabinski, M.; Malinowski, K.; Nanobashvili, S.; Spolaore, M.; Vianello, N.; Gauthier, E.; Gunn, J. P.; Devitre, A.

    2017-12-01

    The COMPASS tokamak at IPP Prague is a small-size device with an ITER-relevant plasma geometry and operating in both the Ohmic as well as neutral beam assisted H-modes since 2012. A basic set of diagnostics installed at the beginning of the COMPASS operation has been gradually broadened in type of diagnostics, extended in number of detectors and collected channels and improved by an increased data acquisition speed. In recent years, a significant progress in diagnostic development has been motivated by the improved COMPASS plasma performance and broadening of its scientific programme (L-H transition and pedestal scaling studies, magnetic perturbations, runaway electron control and mitigation, plasma-surface interaction and corresponding heat fluxes, Alfvenic and edge localized mode observations, disruptions, etc.). In this contribution, we describe major upgrades of a broad spectrum of the COMPASS diagnostics and discuss their potential for physical studies. In particular, scrape-off layer plasma diagnostics will be represented by a new concept for microsecond electron temperature and heat flux measurements - we introduce a new set of divertor Langmuir and ball-pen probe arrays, newly constructed probe heads for reciprocating manipulators as well as several types of standalone probes. Among optical tools, an upgraded high-resolution edge Thomson scattering diagnostic for pedestal studies and a set of new visible light and infrared (plasma-surface interaction investigations) cameras will be described. Particle and beam diagnostics will be covered by a neutral particle analyzer, diagnostics on a lithium beam, Cherenkov detectors (for a direct detection of runaway electrons) and neutron detectors. We also present new modifications of the microwave reflectometer for fast edge density profile measurements.

  20. Application of modern diagnostic methods to environmental improvement. Annual progress report, October 1994--September 1995

    International Nuclear Information System (INIS)

    Shepard, W.S.

    1995-12-01

    The Diagnostic Instrumentation and Analysis Laboratory (DIAL), an interdisciplinary research department in the College of Engineering at Mississippi State University (MSU), is under contract with the US Department of Energy (DOE) to develop and apply advanced diagnostic instrumentation and analysis techniques to aid in solving DOE's nuclear waste problem. The program is a comprehensive effort which includes five focus areas: advanced diagnostic systems; development/application; torch operation and test facilities; process development; on-site field measurement and analysis; technology transfer/commercialization. As part of this program, diagnostic methods will be developed and evaluated for characterization, monitoring and process control. Also, the measured parameters, will be employed to improve, optimize and control the operation of the plasma torch and the overall plasma treatment process. Moreover, on-site field measurements at various DOE facilities are carried out to aid in the rapid demonstration and implementation of modern fieldable diagnostic methods. Such efforts also provide a basis for technology transfer

  1. Application of modern diagnostic methods to environmental improvement. Annual progress report, October 1994--September 1995

    Energy Technology Data Exchange (ETDEWEB)

    Shepard, W.S.

    1995-12-01

    The Diagnostic Instrumentation and Analysis Laboratory (DIAL), an interdisciplinary research department in the College of Engineering at Mississippi State University (MSU), is under contract with the US Department of Energy (DOE) to develop and apply advanced diagnostic instrumentation and analysis techniques to aid in solving DOE`s nuclear waste problem. The program is a comprehensive effort which includes five focus areas: advanced diagnostic systems; development/application; torch operation and test facilities; process development; on-site field measurement and analysis; technology transfer/commercialization. As part of this program, diagnostic methods will be developed and evaluated for characterization, monitoring and process control. Also, the measured parameters, will be employed to improve, optimize and control the operation of the plasma torch and the overall plasma treatment process. Moreover, on-site field measurements at various DOE facilities are carried out to aid in the rapid demonstration and implementation of modern fieldable diagnostic methods. Such efforts also provide a basis for technology transfer.

  2. International evaluation of the programme on engine-related combustion

    Energy Technology Data Exchange (ETDEWEB)

    Arcoumanis, D [Imperial College, London (United Kingdom); Greenhalgh, D [Cranfield Univ. (United Kingdom); Magnusson, B F [Norwegian Univ. of Science and Technology, Trondheim (Norway); Peters, N [Institut fuer Technische Mechanik, RWTH Aachen (Germany)

    1996-11-01

    The 12 projects in the engine related combustion programme cover the entire range from fundamental and theoretical aspects of combustion to more applied subjects such as engine control. The common denominator in the programme clearly is the internal combustion engine, both the reciprocating as well as the gas turbine engine. Such a large coverage by a relatively small number of projects necessarily leads to an isolation of some of the projects in terms of their subject as well as the methodology that is used. On the other hand, all the research areas of interest in combustion technology are represented by at least one of the projects. These are: mathematical and numerical methods in combustion; modelling of turbulent combustion; laser diagnostics of flows with combustion; studies of engine performance and their control; semi-empirical model development for practical applications. As a conclusion, the evaluation committee believes that the programme is well balanced between fundamental and applied projects. It covers the entire range of modern methodologies that are used on the international level and thereby contributes to the application and further development of these research tools in Sweden

  3. Using Bogner and Wiseman's Model of Ecological Values to Measure the Impact of an Earth Education Programme on Children's Environmental Perceptions

    Science.gov (United States)

    Johnson, Bruce; Manoli, Constantinos C.

    2008-01-01

    Investigating the effects of educational programmes on children's environmental perceptions has been hampered by the lack of good theoretical models and valid instruments. In the present study, Bogner and Wiseman's Model of Ecological Values provided a well-developed theoretical model. A validated instrument based on Bogner's Environmental…

  4. A Review of the LHC Beam Instrumentation

    CERN Document Server

    Fischer, Cl

    1998-01-01

    This is a review of the diagnostics presently considered for LHC running in and operation. The purpose of each instrument is given and, except for the pick-ups of the Beam Position Monitoring system w hich have their position already reserved, the optimal location and an estimate of the required length along the vacuum chamber are given.

  5. [Variations in the diagnostic confirmation process between breast cancer mass screening units].

    Science.gov (United States)

    Natal, Carmen; Fernández-Somoano, Ana; Torá-Rocamora, Isabel; Tardón, Adonina; Castells, Xavier

    2016-01-01

    To analyse variations in the diagnostic confirmation process between screening units, variations in the outcome of each episode and the relationship between the use of the different diagnostic confirmation tests and the lesion detection rate. Observational study of variability of the standardised use of diagnostic and lesion detection tests in 34 breast cancer mass screening units participating in early-detection programmes in three Spanish regions from 2002-2011. The diagnostic test variation ratio in percentiles 25-75 ranged from 1.68 (further appointments) to 3.39 (fine-needle aspiration). The variation ratio in detection rates of benign lesions, ductal carcinoma in situ and invasive cancer were 2.79, 1.99 and 1.36, respectively. A positive relationship between rates of testing and detection rates was found with fine-needle aspiration-benign lesions (R(2): 0.53), fine-needle aspiration-invasive carcinoma (R(2): 0 28), core biopsy-benign lesions (R(2): 0.64), core biopsy-ductal carcinoma in situ (R(2): 0.61) and core biopsy-invasive carcinoma (R(2): 0.48). Variation in the use of invasive tests between the breast cancer screening units participating in early-detection programmes was found to be significantly higher than variations in lesion detection. Units which conducted more fine-needle aspiration tests had higher benign lesion detection rates, while units that conducted more core biopsies detected more benign lesions and cancer. Copyright © 2016 SESPAS. Published by Elsevier Espana. All rights reserved.

  6. Instrumentation and quantitative methods of evaluation. Progress report, January 15-September 14, 1986

    International Nuclear Information System (INIS)

    Beck, R.N.

    1986-09-01

    This document reports progress under grant entitled ''Instrumentation and Quantitative Methods of Evaluation.'' Individual reports are presented on projects entitled the physical aspects of radionuclide imaging, image reconstruction and quantitative evaluation, PET-related instrumentation for improved quantitation, improvements in the FMI cyclotron for increased utilization, and methodology for quantitative evaluation of diagnostic performance

  7. Design advances of the Core Plasma Thomson Scattering diagnostic for ITER.

    Czech Academy of Sciences Publication Activity Database

    Scannell, R.; Maslov, M.; Naylor, G.; O’Gorman, T.; Kempenaars, M.; Carr, M.; Bílková, Petra; Böhm, Petr; Giudicotti, L.; Pasqualotto, R.; Bassan, M.; Vayakis, G.; Walsh, M.; Huxford, R.

    2017-01-01

    Roč. 12, November (2017), č. článku C11010. ISSN 1748-0221. [International Symposium on Laser-Aided Plasma Diagnostics (LAPD2017) /18./. Prague, 24.09.2017-28.09.2017] Institutional support: RVO:61389021 Keywords : Nuclear instruments and methods for hot plasma diagnostics * Plasma diagnostics - interferometry * spectroscopy and imaging Subject RIV: BL - Plasma and Gas Discharge Physics OBOR OECD: 2.11 Other engineering and technologies Impact factor: 1.220, year: 2016 http://iopscience.iop.org/article/10.1088/1748-0221/12/11/C11010/pdf

  8. Medical diagnostics with mobile devices: Comparison of intrinsic and extrinsic sensing.

    Science.gov (United States)

    Kwon, L; Long, K D; Wan, Y; Yu, H; Cunningham, B T

    2016-01-01

    We review the recent development of mobile detection instruments used for medical diagnostics, and consider the relative advantages of approaches that utilize the internal sensing capabilities of commercially available mobile communication devices (such as smartphones and tablet computers) compared to those that utilize a custom external sensor module. In this review, we focus specifically upon mobile medical diagnostic platforms that are being developed to serve the need in global health, personalized medicine, and point-of-care diagnostics. Copyright © 2016 Elsevier Inc. All rights reserved.

  9. Preliminary evaluation of the impact of a Web-based HIV testing programme in Abruzzo Region on the prevention of late HIV presentation and associated mortality

    Directory of Open Access Journals (Sweden)

    Ennio Polilli

    2018-04-01

    Full Text Available Objective: This study aimed to analyze the efficacy of a Web-based testing programme in terms of the prevention of late HIV presentation. The clinical characteristics of patients diagnosed with HIV via the Web-based testing programme were compared to those of patients diagnosed in parallel via standard diagnostic care procedures. Methods: This study included the clinical and demographic data of newly diagnosed HIV patients enrolled at the study clinic between February 2014 and June 2017. These patients were diagnosed either via standard diagnostic procedures or as a result of the Web-based testing programme. Results: Eighty-eight new cases of HIV were consecutively enrolled; their mean age was 39.1 ± 13.0 years. Fifty-nine patients (67% were diagnosed through standard diagnostic procedures and 29 (33% patients came from the Web-based testing programme. Late presentation (62% vs. 34%, p = 0.01 and AIDS-defining conditions at presentation (13 vs. 1, p = 0.02 were significantly more frequent in the standard care group than in the Web-based group; four of 13 patients with AIDS diagnosed under standard diagnostic procedures died, versus none in the Web-based testing group (p < 0.001. Conclusions: Web-based recruitment for voluntary and free HIV testing helped to diagnose patients with less advanced HIV disease and no risk of death, from all at-risk groups, in comparison with standard care testing. Keywords: AIDS, HIV, Late presentation, Voluntary and free testing, HIV diagnosis, Sexually transmitted infections

  10. Developing and testing an instrument to measure the presence of conditions for successful implementation of quality improvement collaboratives.

    Science.gov (United States)

    Dückers, Michel L A; Wagner, Cordula; Groenewegen, Peter P

    2008-08-11

    In quality improvement collaboratives (QICs) teams of practitioners from different health care organizations are brought together to systematically improve an aspect of patient care. Teams take part in a series of meetings to learn about relevant best practices, quality methods and change ideas, and share experiences in making changes in their own local setting. The purpose of this study was to develop an instrument for measuring team organization, external change agent support and support from the team's home institution in a Dutch national improvement and dissemination programme for hospitals based on several QICs. The exploratory methodological design included two phases: a) content development and assessment, resulting in an instrument with 15 items, and b) field testing (N = 165). Internal consistency reliability was tested via Cronbach's alpha coefficient. Principal component analyses were used to identify underlying constructs. Tests of scaling assumptions according to the multi trait/multi-item matrix, were used to confirm the component structure. Three components were revealed, explaining 65% of the variability. The components were labelled 'organizational support', 'team organization' and 'external change agent support'. One item not meeting item-scale criteria was removed. This resulted in a 14 item instrument. Scale reliability ranged from 0.77 to 0.91. Internal item consistency and divergent validity were satisfactory. On the whole, the instrument appears to be a promising tool for assessing team organization and internal and external support during QIC implementation. The psychometric properties were good and warrant application of the instrument for the evaluation of the national programme and similar improvement programmes.

  11. Developing and testing an instrument to measure the presence of conditions for successful implementation of quality improvement collaboratives

    Directory of Open Access Journals (Sweden)

    Wagner Cordula

    2008-08-01

    Full Text Available Abstract Background In quality improvement collaboratives (QICs teams of practitioners from different health care organizations are brought together to systematically improve an aspect of patient care. Teams take part in a series of meetings to learn about relevant best practices, quality methods and change ideas, and share experiences in making changes in their own local setting. The purpose of this study was to develop an instrument for measuring team organization, external change agent support and support from the team's home institution in a Dutch national improvement and dissemination programme for hospitals based on several QICs. Methods The exploratory methodological design included two phases: a content development and assessment, resulting in an instrument with 15 items, and b field testing (N = 165. Internal consistency reliability was tested via Cronbach's alpha coefficient. Principal component analyses were used to identify underlying constructs. Tests of scaling assumptions according to the multi trait/multi-item matrix, were used to confirm the component structure. Results Three components were revealed, explaining 65% of the variability. The components were labelled 'organizational support', 'team organization' and 'external change agent support'. One item not meeting item-scale criteria was removed. This resulted in a 14 item instrument. Scale reliability ranged from 0.77 to 0.91. Internal item consistency and divergent validity were satisfactory. Conclusion On the whole, the instrument appears to be a promising tool for assessing team organization and internal and external support during QIC implementation. The psychometric properties were good and warrant application of the instrument for the evaluation of the national programme and similar improvement programmes.

  12. TFTR diagnostic control and data acquisition system

    International Nuclear Information System (INIS)

    Sauthoff, N.R.; Daniels, R.E.; PPL Computer Division

    1985-01-01

    General computerized control and data-handling support for TFTR diagnostics is presented within the context of the Central Instrumentation, Control and Data Acquisition (CICADA) System. Procedures, hardware, the interactive man--machine interface, event-driven task scheduling, system-wide arming and data acquisition, and a hierarchical data base of raw data and results are described. Similarities in data structures involved in control, monitoring, and data acquisition afford a simplification of the system functions, based on ''groups'' of devices. Emphases and optimizations appropriate for fusion diagnostic system designs are provided. An off-line data reduction computer system is under development

  13. The future of medical diagnostics: review paper

    LENUS (Irish Health Repository)

    Jerjes, Waseem K

    2011-08-23

    Abstract While histopathology of excised tissue remains the gold standard for diagnosis, several new, non-invasive diagnostic techniques are being developed. They rely on physical and biochemical changes that precede and mirror malignant change within tissue. The basic principle involves simple optical techniques of tissue interrogation. Their accuracy, expressed as sensitivity and specificity, are reported in a number of studies suggests that they have a potential for cost effective, real-time, in situ diagnosis. We review the Third Scientific Meeting of the Head and Neck Optical Diagnostics Society held in Congress Innsbruck, Innsbruck, Austria on the 11th May 2011. For the first time the HNODS Annual Scientific Meeting was held in association with the International Photodynamic Association (IPA) and the European Platform for Photodynamic Medicine (EPPM). The aim was to enhance the interdisciplinary aspects of optical diagnostics and other photodynamic applications. The meeting included 2 sections: oral communication sessions running in parallel to the IPA programme and poster presentation sessions combined with the IPA and EPPM posters sessions.

  14. Automatic creation of Markov models for reliability assessment of safety instrumented systems

    International Nuclear Information System (INIS)

    Guo Haitao; Yang Xianhui

    2008-01-01

    After the release of new international functional safety standards like IEC 61508, people care more for the safety and availability of safety instrumented systems. Markov analysis is a powerful and flexible technique to assess the reliability measurements of safety instrumented systems, but it is fallible and time-consuming to create Markov models manually. This paper presents a new technique to automatically create Markov models for reliability assessment of safety instrumented systems. Many safety related factors, such as failure modes, self-diagnostic, restorations, common cause and voting, are included in Markov models. A framework is generated first based on voting, failure modes and self-diagnostic. Then, repairs and common-cause failures are incorporated into the framework to build a complete Markov model. Eventual simplification of Markov models can be done by state merging. Examples given in this paper show how explosively the size of Markov model increases as the system becomes a little more complicated as well as the advancement of automatic creation of Markov models

  15. The european approach to quality assurance in diagnostic radiology

    International Nuclear Information System (INIS)

    Benini, A.

    1997-01-01

    The european and increasingly the international organizations are emphasizing the importance of appropriate quality assurance programmes in diagnostic radiology. The European Directive (particularly the directive 84/466/EURATOM). the various publications of the International Commission for radiation protection (ICRP), related to protection of the patients and workers and the Basic Safety Standards of the International Atomic Energy Agency (IAEA) might be considered the landmarks of the new approach to the problems of dose reduction and quality in diagnostic radiology. In particular ICRP maintains a watching brief on all aspects related to radiation protection and makes recommendations concerning basic principles. Since ICRP 26 (1977), several ICRP publications have dealt with all the principal fields of diagnostic radiology. The IAEA has recently published the new Basic Safety Standards including guidance levels for the most common diagnostic investigations.Within the European countries the European Union and the European legislation have strong influence of the implementation of radiation protection and Q A at a national level. This has led to a substantial effort in the european countries to establish national standards and basic quality requirements. (author)

  16. Overview of MFTF supervisory control and diagnostics system software

    International Nuclear Information System (INIS)

    Ng, W.C.

    1979-01-01

    The Mirror Fusion Test Facility (MFTF) at the Lawrence Livermore Laboratory (LLL) is currently the largest mirror fusion research project in the world. Its Control and Diagnostics System is handled by a distributed computer network consisting of nine Interdata minicomputer systems and about 65 microprocessors. One of the design requirements is tolerance of single-point failure. If one of the computer systems becomes inoperative, the experiment can still be carried out, although the system responsiveness to operator command may be degraded. In a normal experiment cycle, the researcher can examine the result of the previous experiment, change any control parameter, fire a shot, collect four million bytes of diagnostics data, perform intershot analysis, and have the result presented - all within five minutes. The software approach adopted for the Supervisory Control and Diagnostics System features chief programmer teams and structured programming. Pascal is the standard programming language in this project

  17. Development, reliability, and validity of the Posttraumatic Stress Disorder Interview for Vietnamese refugees: a diagnostic instrument for Vietnamese refugees.

    Science.gov (United States)

    Dao, Tam K; Poritz, Julia M P; Moody, Rachel P; Szeto, Kim

    2012-08-01

    The Posttraumatic Stress Disorder Interview for Vietnamese Refugees (PTSD-IVR) was created specifically to assess for the presence of current and lifetime history of premigration, migration, encampment, and postmigration traumas in Vietnamese refugees. The purpose of the present study was to describe the development of and investigate the interrater and test-retest reliability of the PTSD-IVR and its validity in relation to the diagnoses obtained from the Longitudinal, Expert, and All Data (LEAD; Spitzer, 1983) standard. Clinicians conducted the diagnosis process with 127 Vietnamese refugees using the LEAD standard and the PTSD-IVR. Assessment of the reliability and validity of the PTSD-IVR yielded good to excellent AUC (area under the receiver operating characteristic curve; .86, .87) and κ values (.66, .74) indicating the reliability of the PTSD-IVR and the agreement between the LEAD procedure and the PTSD-IVR. The results of the present study suggest that the PTSD-IVR performs successfully as a diagnostic instrument specifically created for Vietnamese refugees in their native language. Copyright © 2012 International Society for Traumatic Stress Studies.

  18. UK surplus source disposal programme - 16097

    International Nuclear Information System (INIS)

    John, Gordon H.; Reeves, Nigel; Nisbet, Amy C.; Garnett, Andrew; Williams, Clive R.

    2009-01-01

    The UK Surplus Source Disposal Programme (SSDP), managed by the Environment Agency, was designed to remove redundant radioactive sources from the public domain. The UK Government Department for Environment, Food and Rural Affairs (Defra) was concerned that disused sources were being retained by hospitals, universities and businesses, posing a risk to public health and the environment. AMEC provided a range of technical and administrative services to support the SSDP. A questionnaire was issued to registered source holders and the submitted returns compiled to assess the scale of the project. A member of AMEC staff was seconded to the Environment Agency to provide technical support and liaise directly with source holders during funding applications, which would cover disposal costs. Funding for disposal of different sources was partially based on a sliding scale of risk as determined by the IAEA hazard categorisation system. This funding was also sector dependent. The SSDP was subsequently expanded to include the disposal of luminised aircraft instruments from aviation museums across the UK. These museums often hold significant radiological inventories, with many items being unused and in a poor state of repair. These instruments were fully characterised on site by assessing surface dose rate, dimensions, source integrity and potential contamination issues. Calculations using the Microshield computer code allowed gamma radiation measurements to be converted into total activity estimates for each source. More than 11,000 sources were disposed of under the programme from across the medical, industrial, museum and academic sectors. The total activity disposed of was more than 8.5 E+14 Bq, and the project was delivered under budget. (authors)

  19. Recent developments in nuclear instruments

    International Nuclear Information System (INIS)

    Vaidya, P.P.

    2004-01-01

    Full text : Nuclear Instrumentation is a field of vital importance for DAE. It has important applications in many areas of interest such as Reactor Monitoring and control, Accelerator based research, Laser and nuclear physics experiments, Health and environmental monitoring, Astrophysics experiments etc. It is a specialized field involving expertise in detection of radioactivity down to the level of few events per minute as well as processing and analysis of signals which can be as small as few hundred micro volts embedded in noise. Some applications involve digitizing and processing these signals with 0.001% accuracy and timing accuracies of a fraction of nano sec. Rapid developments in semiconductor related technologies have influenced the field of nuclear instrumentation. Development of FPGA's and ASIC's have made it possible to develop miniaturized smart and portable instruments for field applications. Advancements in field of computers, communications and various field buses have been successfully utilized for smart, portable and DSP based instrumentation. Smart sensor with detector and front-end electronics on a single silicon chip is now a reality. These instruments are also made intelligent by addition of fuzzy logic, artificial neural networks and expert systems. Electronics Division of BARC has made significant contribution to the field of nuclear instrumentation to achieve self-reliance in this area. This has also led to development of several new methods, which have been published in international journals and appreciated worldwide. As a step towards achieving complete self-reliance a programme for development of FPGA's, HMC's and ASIC's has been undertaken and is being followed with special emphasis. This also includes development of detector and front- end electronics on a single chip. This talk brings out details of these developments and describes the 'state of art' work done in India

  20. Research within the coordinated programme on investigation of maintenance of nuclear instrumentation in developing countries. Latin America

    International Nuclear Information System (INIS)

    Guzman-Acevedo, C.

    1980-06-01

    The situation in Peru with regard to the maintenance and repair of instruments used in nuclear medicine is presented. On the basis of responses to questionnaires it appears that 56 instruments for nuclear medicine are in use in the country, almost exclusively in the capital Lima. The average age of the instruments is 9.5 years. They are in use about 16.4% of the possible time. The development of nuclear medicine in Peru is in its initial stages and difficulties encountered arise both from the lack of training and experience in nuclear medicine on the part of the medical personnel as well as lack of experience of the technicians responsible for instrument maintenance. Practically no preventive maintenance ever takes place; action is only taken when an instrument breaks down. Various suggestions are made in order to attempt an improvement of the situation

  1. Virtual Sensor Test Instrumentation

    Science.gov (United States)

    Wang, Roy

    2011-01-01

    Virtual Sensor Test Instrumentation is based on the concept of smart sensor technology for testing with intelligence needed to perform sell-diagnosis of health, and to participate in a hierarchy of health determination at sensor, process, and system levels. A virtual sensor test instrumentation consists of five elements: (1) a common sensor interface, (2) microprocessor, (3) wireless interface, (4) signal conditioning and ADC/DAC (analog-to-digital conversion/ digital-to-analog conversion), and (5) onboard EEPROM (electrically erasable programmable read-only memory) for metadata storage and executable software to create powerful, scalable, reconfigurable, and reliable embedded and distributed test instruments. In order to maximize the efficient data conversion through the smart sensor node, plug-and-play functionality is required to interface with traditional sensors to enhance their identity and capabilities for data processing and communications. Virtual sensor test instrumentation can be accessible wirelessly via a Network Capable Application Processor (NCAP) or a Smart Transducer Interlace Module (STIM) that may be managed under real-time rule engines for mission-critical applications. The transducer senses the physical quantity being measured and converts it into an electrical signal. The signal is fed to an A/D converter, and is ready for use by the processor to execute functional transformation based on the sensor characteristics stored in a Transducer Electronic Data Sheet (TEDS). Virtual sensor test instrumentation is built upon an open-system architecture with standardized protocol modules/stacks to interface with industry standards and commonly used software. One major benefit for deploying the virtual sensor test instrumentation is the ability, through a plug-and-play common interface, to convert raw sensor data in either analog or digital form, to an IEEE 1451 standard-based smart sensor, which has instructions to program sensors for a wide variety of

  2. Integrating exhaled breath diagnostics by disease-sniffing dogs with instrumental laboratory analysis

    Science.gov (United States)

    Dogs have been studied for many years as a medical diagnostic tool to detect a pre-clinical disease state by sniffing emissions directly from a human or an in vitro biological sample. Some of the studies report high sensitivity and specificity in blinded case-control studies. How...

  3. Diagnostics for FIRE: A Status Report

    International Nuclear Information System (INIS)

    Kenneth M. Young

    2002-01-01

    The mission for the proposed FIRE (Fusion Ignition Research Experiment) device is to ''attain, explore, understand and optimize fusion-dominated plasmas.'' Operation at Q * 5, for 20 sec with a fusion power output of *150 MW is the major goal. Attaining this mission sets demands for plasma measurement that are at least as comprehensive as on present tokamaks, with the additional capabilities needed for control of the plasma and for understanding the effects of the alpha-particles. Because of the planned operation in advanced tokamak scenarios, with steep transport barriers, the diagnostic instrumentation must be able to provide fine spatial and temporal resolution. It must also be able to withstand the impact of the intense neutron and gamma irradiation. There are practical engineering issues of minimizing radiation streaming while providing essential diagnostic access to the plasma. Many components will operate close to the first wall, e.g. ceramics and mineral insulated cable for magnetic diagnostics and mirrors for optical diagnostics; these components must be selected and mounted so that they will operate and survive in fluxes which require special material selection. The measurement requirements have been assessed so that the diagnostics for the FIRE device can be defined. Clearly a better set of diagnostics of alpha-particles than that available for TFTR is essential, since the alpha-particles provide the dominant sources of heating and of instability-drive in the plasma

  4. A specialized isotope mass spectrometer for noninvasive diagnostics of Helicobacter pylori infection in human beings

    Science.gov (United States)

    Blashenkov, N. M.; Sheshenya, E. S.; Solov'ev, S. M.; Sachenko, V. D.; Gall, L. N.; Zarutskii, I. V.; Gall, N. R.

    2013-05-01

    A specialized isotope mass spectrometer for noninvasive diagnostics of Helicobacter pylori infection in human beings based on the carbon-13 isotope breath test has been designed and constructed. Important stages of the work included (i) calculating a low-aberration mass analyzer, (ii) manufacturing and testing special gas inlet system, and (iii) creating a small-size collector of ions. The proposed instrument ensures 13C/12C isotopic ratio measurement to within 1.7‰ (pro mille) accuracy, which corresponds to requirements for a diagnostic tool. Preliminary medical testing showed that the mass spectrometer is applicable to practical diagnostics. The instrument is also capable of measuring isotopic ratios of other light elements, including N, O, B (for BF2+ ions), Ar, Cl, and S.

  5. A Braille Interface to the Texas Instruments SR-52 Programmable Calculator.

    Science.gov (United States)

    1976-09-21

    F / _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ AD—A039 US PENNSYLVANIA STATE UNIV JNIVtRSITY PARK APPLIED RESE——ETc F/G 9/2 * BRAILLE INTERFACE to PC TEXAS...UNCLASSiFIED A BRAILLE INTERFACE TO THE TEXAS INSTRUMENTS SR-52 PR0CRA)*~ABLE CALCULATOR C. P~ JANOTA Technical Memorandum D D C File No. TM 76-244 i...SUPPLEMENTARY NOTES ~~~~ ~ 15. KEY WORDS (ConUnti. on ,.v.ra• .Id. If nøc....ry and td~n t tf y by block ntanb.r) AIDS TO HANDICAPPED BRAILLE INTERFACE

  6. New trends in ellipsometry for thin film diagnostics

    International Nuclear Information System (INIS)

    Masetti, E.

    1987-01-01

    Ellipsometric technique is both instrumentation and method for surface characterization through light polarization change measurements. After the improvement of the technique due to electrooptical components (light polarization modulator) and personal computer, ellipsometry today is getting new interest in optical thin film diagnostics because of automatized ellipsometer availability. The realization of a new instrument for light polarization measurement, the FDP (Four Detector Photopolarimeter), will allow the production of ellipsometers with improved characteristics and low cost. A survey on ellipsometric technique trend and preliminary data on the first realized FDP are reported

  7. Integrated conception of hardware/software mixed systems used in nuclear instrumentation

    International Nuclear Information System (INIS)

    Dias, Ailton F.; Sorel, Yves; Akil, Mohamed

    2002-01-01

    Hardware/software codesign carries out the design of systems composed by a hardware portion, with specific components, and a software portion, with microprocessor based architecture. This paper describes the Algorithm Architecture Adequation (AAA) design methodology - originally oriented to programmable multicomponent architectures, its extension to reconfigurable circuits and its application to design and development of nuclear instrumentation systems composed by programmable and configurable circuits. AAA methodology uses an unified model to describe algorithm, architecture and implementation, based on graph theory. The great advantage of AAA methodology is the utilization of a same model from the specification to the implementation of hardware/software systems, reducing the complexity and design time. (author)

  8. Intelligent data-acquisition instrumentation for special nuclear material assay data analysis

    International Nuclear Information System (INIS)

    Ethridge, C.D.

    1980-01-01

    The Detection, Surveillance, Verification, and Recovery Group of the Los Alamos Scientific Laboratory Energy Division/Nuclear Safeguards Programs is now utilizing intelligent data-acquisition instrumentation for assay data analysis of special nuclear material. The data acquisition and analysis are enabled by the incorporation of a number-crunching microprocessor sequenced by a single component microcomputer. Microcomputer firmware establishes the capability for processing the computation of several selected functions and also the ability of instrumentation self-diagnostics

  9. Proceedings of the Specialist Meeting on Severe Accident Management Programme Development

    International Nuclear Information System (INIS)

    1992-04-01

    Effective Accident Management planning can produce both a reduction in the frequency of severe accidents at nuclear power plants as well as the ability to mitigate a severe accident. The purpose of an accident management programme is to provide to the responsible plant staff the capability to cope with the complete range of credible severe accidents. This requires that appropriate instrumentation and equipment are available within the plant to enable plant staff to diagnose the faults and to implement appropriate strategies. The programme must also provide the necessary guidance, procedures, and training to assure that appropriate corrective actions will be implemented. One of the key issues to be discussed is the transition from control room operations and the associated emergency operating procedures to a technical support team approach (and the associated severe accident management strategies). Following a proposal made by the Senior Group of Experts on Severe Accident Management (SESAM), the Committee on the Safety of Nuclear Installations decided to sponsor a Specialist Meeting on Severe Accident Management Programme Development. The general objectives of the Specialist Meeting were to exchange experience, views, and information among the participants and to discuss the status of severe accident management programmes. The meeting brought together utilities, accident management programme developers, personnel training programme developers, regulators, and researchers. In general, the tone of the Specialist Meeting - designed to promote progress, as contrasted with conferences or symposia where the state-of-the-art is presented - was to be rather practical, and focus on accident management programme development, applications, results, difficulties and improvements. As shown by the conclusions of the meeting, there is no doubt that this objective was widely attained

  10. Proceedings of the Specialist Meeting on Severe Accident Management Programme Development

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1992-04-15

    Effective Accident Management planning can produce both a reduction in the frequency of severe accidents at nuclear power plants as well as the ability to mitigate a severe accident. The purpose of an accident management programme is to provide to the responsible plant staff the capability to cope with the complete range of credible severe accidents. This requires that appropriate instrumentation and equipment are available within the plant to enable plant staff to diagnose the faults and to implement appropriate strategies. The programme must also provide the necessary guidance, procedures, and training to assure that appropriate corrective actions will be implemented. One of the key issues to be discussed is the transition from control room operations and the associated emergency operating procedures to a technical support team approach (and the associated severe accident management strategies). Following a proposal made by the Senior Group of Experts on Severe Accident Management (SESAM), the Committee on the Safety of Nuclear Installations decided to sponsor a Specialist Meeting on Severe Accident Management Programme Development. The general objectives of the Specialist Meeting were to exchange experience, views, and information among the participants and to discuss the status of severe accident management programmes. The meeting brought together utilities, accident management programme developers, personnel training programme developers, regulators, and researchers. In general, the tone of the Specialist Meeting - designed to promote progress, as contrasted with conferences or symposia where the state-of-the-art is presented - was to be rather practical, and focus on accident management programme development, applications, results, difficulties and improvements. As shown by the conclusions of the meeting, there is no doubt that this objective was widely attained.

  11. An FPGA-based instrumentation platform for use at deep cryogenic temperatures

    Energy Technology Data Exchange (ETDEWEB)

    Conway Lamb, I. D.; Colless, J. I.; Hornibrook, J. M.; Pauka, S. J.; Waddy, S. J.; Reilly, D. J., E-mail: david.reilly@sydney.edu.au [ARC Centre of Excellence for Engineered Quantum Systems, School of Physics, The University of Sydney, Sydney NSW 2006 (Australia); Microsoft Station Q Sydney, The University of Sydney, Sydney NSW 2006 (Australia); Frechtling, M. K. [Microsoft Station Q Sydney, The University of Sydney, Sydney NSW 2006 (Australia); School of Electrical Engineering, The University of Sydney, Sydney NSW 2006 (Australia)

    2016-01-15

    We describe the operation of a cryogenic instrumentation platform incorporating commercially available field-programmable gate arrays (FPGAs). The functionality of the FPGAs at temperatures approaching 4 K enables signal routing, multiplexing, and complex digital signal processing in close proximity to cooled devices or detectors within the cryostat. The performance of the FPGAs in a cryogenic environment is evaluated, including clock speed, error rates, and power consumption. Although constructed for the purpose of controlling and reading out quantum computing devices with low latency, the instrument is generic enough to be of broad use in a range of cryogenic applications.

  12. Programme

    OpenAIRE

    Hobday, E, fl. 1905, artist

    2003-01-01

    A photograph of an illustrated programme listing dances. The illustration shows a snake charmer playing to a snake while another man watches. Buildings and trees can be seen behind a wall in the distance. In the lower right-hand corner of the programme is the signature 'E. Hobday'. The programme is almost certainly related to the Punjab Ball, Lahore. It is placed next to the Punjab Ball Menu in the album and the Menu is also illustrated by 'E. Hobday'.

  13. New kind of user interface for controlling MFTF diagnostics

    International Nuclear Information System (INIS)

    Preckshot, G.G.; Saroyan, R.A.; Mead, J.E.

    1983-01-01

    The Mirror Fusion Test Facility (MFTF) at Lawrence Livermore National Laboratory is faced with the problem of controlling a multitude of plasma diagnostics instruments from a central, multiprocessor computer facility. A 16-bit microprocessor-based workstation allows each physicist entree into the central multiprocessor, which consists of nine Perkin-Elmer 32-bit minicomputers. The workstation provides the user interface to the larger system, with display graphics, windowing, and a physics notebook. Controlling a diagnostic is now equivalent to making entries into a traditional physics notebook

  14. Double-contrast imaging of the pharynx in case of dysphagia as the leading symptom. Methodology and diagnostic value

    Energy Technology Data Exchange (ETDEWEB)

    Feyerabend, T; Schmitt, R; Richter, E; Bohndorf, W

    1989-01-01

    The article explains the value of double-contrast pharyngography in the gradual programme of diagnostic means for clarifying the symptom of dysphagia. The method is simple and quick and well suited as a first screening method before more complicated methods are used. It allows reliable assessment of postoperative or postradiogenic morphology in case of malignant oro- or hypopharynx tumors and thus also is suitable for tumor aftercare programmes. (orig./GDG).

  15. Holy Trinity of Instrumentation Development

    International Nuclear Information System (INIS)

    Ursic, Rok; Solar, Borut

    2004-01-01

    Being user friendly should be the main guidance, beside the self-understood high performance, in today's instrumentation development. Here we identify three components of the user-friendly policy: the all-in-one concept, customization, and connectivity. All-in-one is the concept of unification of various building blocks and thus various functionalities in one product. The customization is enabled by the product's reconfigurability that allows a product to grow and support new requirements and applications without changing hardware. The consequence of the two is the capacity of the single instrument to perform a variety of tasks that before were split among different devices. The last of the three is connectivity that improves the relationship between controls and beam diagnostics, brings out-of-the-crate freedom, and opens unforeseen possibilities for intra-accelerator cooperation and remote technical support

  16. Clinical Training of Medical Physicists Specializing in Diagnostic Radiology

    International Nuclear Information System (INIS)

    2010-01-01

    The application of radiation in human health, for both diagnosis and treatment of disease, is an important component of the work of the IAEA. The responsibility for the increasing technical aspects of this work is undertaken by the medical physicist. To ensure good practice in this vital area, structured clinical training programmes are required to complement academic learning. This publication is intended to be a guide to the practical implementation of such a programme for diagnostic radiology. There is a general and growing awareness that radiation medicine is increasingly dependent on well trained medical physicists based in the clinical setting. However, an analysis of the availability of medical physicists indicates a large shortfall of qualified and capable professionals. This is particularly evident in developing countries. While strategies to increase academic educational opportunities are critical to such countries, the need for guidance on structured clinical training was recognized by the members of the Regional Cooperative Agreement (RCA) for Research, Development and Training related to Nuclear Sciences for Asia and the Pacific. Consequently, a technical cooperation regional project (RAS6038) under the RCA programme was formulated to address this need in the Asia-Pacific region by developing suitable material and establishing its viability. Development of a clinical training guide for medical physicists specializing in diagnostic radiology started in 2007 with the appointment of a core drafting committee of regional and international experts. The publication drew on the experiences of clinical training programmes in Australia and New Zealand, the UK and the USA, and was moderated by physicists working in the Asian region. This publication follows the approach of the IAEA publication Training Course Series No. 37, Clinical Training of Medical Physicists specializing in Radiation Oncology. This approach to clinical training has been successfully tested

  17. Beam profile diagnostics system for SDUV-FEL

    International Nuclear Information System (INIS)

    Xu Yichao; Han Lifeng; Chen Yongzhong

    2010-01-01

    A new beam profile diagnostics system for Shanghai Deep Ultraviolet Free Electron Laser (SDUV-FEL) has been developed based on industrial Ethernet, with good versatility and scalability. The system includes three major subsystems for image acquisition,pneumatic control and stepper motor control, respectively. Virtual instrument technology is adopted to drive the devices, and to develop the measurement software. In this paper,we describe the system structure, and its hardware and software design. The results of system commissioning are given as well. As an important diagnostic tool and data acquisition method, the system has been successfully applied to the measurement and control of the SDUV-FEL.(authors)

  18. Experts and equipment: The IAEA programme in 1965

    International Nuclear Information System (INIS)

    1965-01-01

    Nearly 100 projects are being assisted by Agency experts and equipment in 38 countries under the 1965 programme to be financed from Agency funds, which the Board of Governors approved at its meeting in February, together with four other countries where projects previously approved extend into 1965. In addition, further work is being financed under the UN Expanded Programme of Technical Assistance, including several important regional projects. Under the Agency's long-term programme, it is desirable that all types of technical assistance, whether training, research, or expert advice, should be combined as far as possible. Each country will therefore be asked, in respect of its 1966 programme, to make its requests for experts, equipment, fellowships, scientific visits and research grants as a single submission. The Agency then prepares a country programme of technical assistance, in collaboration with the Government. The number of requests for experts and equipment continues to grow year by year, and it has not been possible to finance them all. This increase is largely because a number of Member States have now set up research reactors and established a nucleus of laboratories under bilateral arrangements; they then turn to the Agency for assistance in developing their programmes. The estimated cost of experts and equipment being provided from Agency resources is $874 000 in 1965, of which $596 800 is for experts, and $277 200 is for equipment and supplies. The Agency also assists some Member States in making arrangements to receive technical assistance directly from other Member States. The work covers a wide range, with isotopes predominating; about 30 projects deal with production of isotopes, their applications in medicine, agriculture and hydrology, in food preservation and industry. A number of projects are concerned with various aspects of reactor construction and use; others deal with health and safety, instrumentation, special branches of chemistry and

  19. Nuclear Engineering Education in Support of Thailand’s Nuclear Power Programme

    International Nuclear Information System (INIS)

    Chanyotha, S.; Pengvanich, P.; Nilsuwankosit, S.

    2015-01-01

    This paper aims to introduce the nuclear engineering education at the Department of Nuclear Engineering, Chulalongkon University, Bangkok Thailand. The department has been offering curriculum in nuclear engineering to support the national nuclear power programme since 1970s. It is the oldest established nuclear engineering educational programme in the South East Asia region. Nevertheless, since the nuclear power programme has been postponed several times due to various reasons, the educational programme at the department has been continuously adapted to meet the nation’s needs. Several areas of study have been introduced, including nuclear power engineering, industrial applications of radioisotope, nuclear instrumentation, radioisotope production, radiation processing, environment and safety, nuclear materials, as well as the newly created nuclear security and non-proliferation. With the renewed interest in using nuclear power in Thailand in 2007, the department has been actively assisting both the government and the electric utility in preparing human resources to support the nuclear power programme through various educational and training modules. Realizing the importance of establishing and balancing all 3 aspects of the nuclear 3S (safety, security and safeguard) in Thailand and in the Southeast Asian region. The new curriculum of nuclear security and safeguard programme has been offered since 2013. Since the establishment, the department has produced hundreds of graduates (Diploma, Master’s, and Ph.D. levels) to feed the continuously expanding Thai nuclear industry. The full paper will provide detailed information of the curriculum, the challenges and obstacles that the department has encountered, as well as the national and international linkages which have been established over the years. (author)

  20. Crispv programme

    International Nuclear Information System (INIS)

    Marinkovicj, N.

    CRISPV (Criticality and Spectrum code) is a multigroup neutron spectrum code for homogeneous reactor cores and is actually a somewhat modified version of the original CRISP programme. It is a combination of DATAPREP-II and BIGG-II programmes. It is assumed that the reactor cell is a cylindrical fuel rod in the light or heavy water moderator. DATEPREP-II CODE forms the multigroup data for homogeneous reactor and prepares the input parameters for the BIGG-II code. It has its own nuclear data library on a separate tape in binary mode. BIGG-II code is a multigroup neutron spectrum and criticality code for a homogenized medium. It has as well its own separate data library. In the CRISPV programme the overlay structure enables automatic handling of data calculated in the DATAPREP-II programme and needed in the BIGG-II core. Both programmes are written in FORTRAN for CDC 3600. Using the programme is very efficient and simple

  1. National programme: Finland

    International Nuclear Information System (INIS)

    Forsten, J.

    1986-01-01

    Finland's programmes in the field of reactor pressure components are presented in this paper. The following information on each of these programmes is given: the brief description of the programme; the programme's schedule and duration; the name of the project manager

  2. An IEC standard on quality assurance for diagnostic X-ray systems

    International Nuclear Information System (INIS)

    Boer, J.A. den

    1985-01-01

    A presentation is given of some characteristics of the International Electrotechnical Commission (IEC). This is followed by a short discussion of general aspects of quality assurance in the diagnostic department. From this discussion it becomes apparent to which aspects of quality assurance IEC can contribute. Within that framework a working group of Sub-Committee 62 is at present active in developing a standard on quality assurance for diagnostic X-ray systems. The standard will contain a set of constancy tests that is claimed to allow a balanced quality assurance programme. The democratic procedure of IEC should guarantee that the proposed standard gains wide acceptance. (author)

  3. A labview approach to instrumentation for the TFTR bumper limiter alignment project

    International Nuclear Information System (INIS)

    Skelly, G.N.; Owens, D.K.

    1992-01-01

    This paper reports on a project recently undertaken to measure the alignment of the TFTR bumper limiter in relation to the toroidal magnetic field axis. The process involved the measurement of the toroidal magnetic field, and the positions of the tiles that make up the bumper limiter. The basis for the instrument control and data acquisition system was National Instrument's LabVIEW 2. LabVIEW is a graphical programming system for developing scientific and engineering applications on a Macintosh. For this project, a Macintosh IIci controlled the IEEE-488 GPIB programmable instruments via an interface box connected to the SCSI port of the computer. With LabVIEW, users create graphical software modules called virtual instruments instead of writing conventional text-based code. To measure the magnetic field, the control system acquired data from two nuclear magnetic resonance magnetometers while the torroidal field coils were pulsed. To measure the position of the tiles on the limiter, an instrumented mechanical arm was used inside the vessel

  4. Teacher Support in Learning: Instrumental and Appraisal Support in Relation to Math Achievement

    Science.gov (United States)

    Wong, Tracy K. Y.; Tao, Xi; Konishi, Chiaki

    2018-01-01

    This study explored the extent to which teachers' instrumental (i.e., tangible aid to promote learning) and appraisal support (i.e., teacher feedback) enhanced students' achievement in mathematics. Participants included 13,950 fifteen-year-old Canadian students who participated in the 2012 Programme for International Student Assessment. Based on…

  5. Forge: a short pulse x-ray diagnostic development facility

    International Nuclear Information System (INIS)

    Stradling, G.L.; Hurry, T.R.; Denbow, E.R.; Selph, M.M.; Ameduri, F.P.

    1985-01-01

    A new short pulse x-ray calibration facility has been brought on line at Los Alamos. This facility is being used for the development, testing and calibration of fast x-ray diagnostic systems. The x-ray source consists of a moderate size, sub-nanosecond laser focused at high intensity on an appropriate target material to generate short pulses of x-ray emission from the resulting plasma. Dynamic performance parameters of fast x-ray diagnostic instruments, such as x-ray streak cameras, can be conveniently measured using this facility

  6. Near instrument-free, simple molecular device for rapid detection of herpes simplex viruses.

    Science.gov (United States)

    Lemieux, Bertrand; Li, Ying; Kong, Huimin; Tang, Yi-Wei

    2012-06-01

    The first near instrument-free, inexpensive and simple molecular diagnostic device (IsoAmp HSV, BioHelix Corp., MA, USA) recently received US FDA clearance for use in the detection of herpes simplex viruses (HSV) in genital and oral lesion specimens. The IsoAmp HSV assay uses isothermal helicase-dependent amplification in combination with a disposable, hermetically-sealed, vertical-flow strip identification. The IsoAmp HSV assay has a total test-to-result time of less than 1.5 h by omitting the time-consuming nucleic acid extraction. The diagnostic sensitivity and specificity are comparable to PCR and are superior to culture-based methods. The near instrument-free, rapid and simple characteristics of the IsoAmp HSV assay make it potentially suitable for point-of-care testing.

  7. Diagnostic radiology physics: A handbook for teachers and students. Endorsed by: American Association of Physicists in Medicine, Asia-Oceania Federation of Organizations for Medical Physics, European Federation of Organisations for Medical Physics

    Energy Technology Data Exchange (ETDEWEB)

    Dance, D. R. [Royal Surrey County Hospital, Guildford (United Kingdom); Christofides, S. [New Nicosia General Hospital (Cyprus); Maidment, A. D.A. [University of Pennsylvania (United States); McLean, I. D. [International Atomic Energy Agency, Vienna (Austria); Ng, K. H. [University of Malaya, Kuala Lumpur (Malaysia)

    2014-09-15

    This publication is written for students and teachers involved in programmes that train medical physicists for work in diagnostic radiology. It provides, in the form of a syllabus, a comprehensive overview of the basic medical physics knowledge required for the practice of modern diagnostic radiology. This makes it particularly useful for graduate students and residents in medical physics programmes. The material presented in the publication has been endorsed by the major international organizations and is the foundation for academic and clinical courses in both diagnostic radiology physics and in emerging areas such as imaging in radiotherapy.

  8. Advanced Data Acquisition System Implementation for the ITER Neutron Diagnostic Use Case Using EPICS and FlexRIO Technology on a PXIe Platform

    Science.gov (United States)

    Sanz, D.; Ruiz, M.; Castro, R.; Vega, J.; Afif, M.; Monroe, M.; Simrock, S.; Debelle, T.; Marawar, R.; Glass, B.

    2016-04-01

    To aid in assessing the functional performance of ITER, Fission Chambers (FC) based on the neutron diagnostic use case deliver timestamped measurements of neutron source strength and fusion power. To demonstrate the Plant System Instrumentation & Control (I&C) required for such a system, ITER Organization (IO) has developed a neutron diagnostics use case that fully complies with guidelines presented in the Plant Control Design Handbook (PCDH). The implementation presented in this paper has been developed on the PXI Express (PXIe) platform using products from the ITER catalog of standard I&C hardware for fast controllers. Using FlexRIO technology, detector signals are acquired at 125 MS/s, while filtering, decimation, and three methods of neutron counting are performed in real-time via the onboard Field Programmable Gate Array (FPGA). Measurement results are reported every 1 ms through Experimental Physics and Industrial Control System (EPICS) Channel Access (CA), with real-time timestamps derived from the ITER Timing Communication Network (TCN) based on IEEE 1588-2008. Furthermore, in accordance with ITER specifications for CODAC Core System (CCS) application development, the software responsible for the management, configuration, and monitoring of system devices has been developed in compliance with a new EPICS module called Nominal Device Support (NDS) and RIO/FlexRIO design methodology.

  9. Core instrumentation and pre-operational procedures for core conversion HEU to LEU

    International Nuclear Information System (INIS)

    1984-02-01

    This report is intended for the reactor operator, to be used as a manual or checklist for general guidance on pre-startup activities that need to be addressed in preparation for conversion to Low Enriched Fuel (LEU). All nuclear, thermodynamic and safety calculations should have been performed prior to this stage of the core conversion process. During these calculations and certainly before ordering the new LEU fuel elements the reactor operator needs to very carefully consider additional important factors concerning the new fuel: fuel reliability, reliability of fuel fabricator, reprocessing contract or fuel element storage and disposal, economics of the new fuel cycle. At this stage, too, a preoperational experimental programme has to be developed and presented to the regulatory authorities for approval. This experimental programme could lead to additional requirements on: in-core instrumentation, out-of-core instrumentation or additional experimental devices. Detailed instructions on specific tests and measurements are not provided in this report since much information on the subject is available in the open literature

  10. Topical Conference on High Temperature Plasma Diagnostics, 7th, Napa, CA, Mar. 13-17, 1988, Proceedings

    International Nuclear Information System (INIS)

    Luhmann, N.C. Jr.; Peebles, W.A.

    1988-01-01

    Various papers concerning scientific instruments are presented. The general topics addressed include: laser scattering and optical diagnostics, collective scattering and interferometry, millimeter wave and current profile measurements, particle-based diagnostics, data acquisition and analysis, X-ray diagnostics, and particle- and photon-based diagnostics. Individual subjects discussed include: atomic hydrogen density measurements in an ion source plasma using VUV absorption spectrometer, resonant diagnostics of laser-produced Ba plasmas, radiative and diffusional effects to the population densities of the excited-state atoms in hydrogen plasma, and Watt-level millimeter-wave monolithic diode-grid frequency multipliers

  11. Promoting interdisciplinary education - the Vienna Doctoral Programme on Water Resource Systems

    Science.gov (United States)

    Blöschl, G.; Carr, G.; Bucher, C.; Farnleitner, A. H.; Rechberger, H.; Wagner, W.; Zessner, M.

    2012-02-01

    The Vienna Doctoral Programme on Water Resource Systems (DK-WRS) is a programme that aims to educate students in interdisciplinary water science through cutting edge research at an international level. It is funded by the Austrian Science Fund and designed to run over a period of 12 yr during which 80 doctoral students are anticipated to graduate. This paper reports on our experiences of setting up and implementing the Programme. We identify three challenges: integrating the disciplines, maintaining depth in an interdisciplinary programme, and teaching subjects remote to each student's core expertise. To address these challenges we adopt a number of approaches. We use three levels of instruments to foster integration across the disciplines: joint groups (e.g. a joint study programme), joint science questions (e.g. developed in annual symposia), and joint study sites. To maintain depth we apply a system of quality control including regular feedback sessions, theses by journal publications and international study exchange. For simultaneously teaching students from civil and environmental engineering, biology, geology, chemistry, mathematics we use visually explicit teaching, learning by doing, extra mentoring and by cross relating associated subjects. Our initial assessment of the Programme shows some very positive outcomes. Joint science questions formed between students from various disciplines indicate integration is being achieved. The number of successful publications in top journals suggests that depth is maintained. Positive feedback from the students on the variety and clarity of the courses indicates the teaching strategy is working well. Our experiences have shown that implementing and running an interdisciplinary doctoral programme has its challenges and is demanding in terms of time and human resources but seeing interactions progress and watching people grow and develop their way of thinking in an interdisciplinary environment is a valuable reward.

  12. A summary of the performance of exposure rate and dose rate instruments contained in instrument evaluation reports NRPB-IE1 to NRPB-IE13

    International Nuclear Information System (INIS)

    Burgess, P.H.; Iles, W.J.

    1979-06-01

    of the instrument evaluation programme and published in the NRPB-IE report series

  13. The Radio & Plasma Wave Investigation (RPWI) for JUICE - Instrument Concept and Capabilities

    Science.gov (United States)

    Bergman, J. E. S.

    2013-09-01

    We present the concept and capabilities of the Radio & Plasma Waves Investigation (RPWI) instrument for the JUICE mission. The RPWI instrument provides measurements of plasma, electric- and magnetic field fluctuations from near DC up to 45 MHz. The RPWI sensors are four Langmuir probes for low temperature plasma diagnostics and electric field measurements, a three-axis searchcoil magnetometer for low-frequency magnetic field measurements, and a three-axial radio antenna, which operates from 80 kHz up to 45 MHz and thus gives RPWI remote sensing capabilities.. In addition, active mutual impedance measurements are used to diagnose the in situ plasma. The RPWI instrument is unique as it provides vector field measurements in the whole frequency range. This makes it possible to employ advanced diagnostics techniques, which are unavailable for scalar measurements. The RPWI instrument has thus outstanding new capabilities not previously available to outer planet missions, which and enables RPWI to address many fundamental planetary science objectives, such as the electrodynamic influence of the Jovian magnetosphere on the exospheres, surfaces and conducting oceans of Ganymede, Europa, and Callisto. RPWI will also be able to investigate the sources of radio emissions from auroral regions of Ganymede and Jupiter, in detail and with unprecedented sensitivity, and possibly also lightning. Moreover, RPWI can search for exhaust plumes from cracks on the icy moons, as well as μm-sized dust and related dust-plasmasurface interaction processes occurring near the icy moons of Jupiter. The top-level blockdiagram of the RPWI instrument is shown here. A detailed technical description of the RPWI instrument will be given.

  14. ELF - An experimental programme to quantify the effects of load follow and perturbated power histories

    International Nuclear Information System (INIS)

    Bairiot, H.; Hass, D.; Stora, J.P.

    1984-01-01

    Most of the ramp tests performed in national or international programmes have as main objective to define the fuel rod failure/survival limits, as a function of various parameters. Only a few of these experiments are sufficiently instrumented. The main feature of the ELF programme, described in this paper, consists in continuously measuring the cladding diameter during irradiation in OSIRIS of pre-irradiated PWR fuel rods, in order to provide strain relaxation data under various operating conditions. Power fluctuations during these OSIRIS irradiations are defined in order to obtain the conditioning and deconditioning kinetics of the fuel rods. (author)

  15. The Euratom research and training framework programme in its wider context

    International Nuclear Information System (INIS)

    Deffrennes, Marc

    2008-01-01

    Nuclear Energy is today providing 1/3 of the electricity in the EU: 150 Nuclear Power Plants generate 130 GWe. The EU has a recognised leadership in nuclear technology with competencies in all aspects of the fuel cycle. Nevertheless there are major challenges: - Energy-related and technical challenges: security of supply, environmental protection and waste issues, competitiveness, and non-proliferation issues. - The political challenge, which affects Europe in particular with differences of opinion between Member States on this sensitive issue. - The ageing of the nuclear expertise, especially acute in Europe, but also has a global dimension. There are a number of EU strategic initiatives in the area of technology/R and D, linking policy and financing instruments, that are helping to address the technical challenges above: - The Euratom Research and Training Programme - the Commission's Energy Package of 10 January 2007, endorsed by Council a few months later, sets the well known 2020 3 x 20 targets, and announces the associated Strategic Energy Technology Plan - SET Plan. - A key Commission-promoted initiative, the Sustainable Nuclear Energy Technology Platform (SNE-TP). - The Commission is also now fostering the International Cooperation dimension of the Euratom Framework Programme, in synergy with other specific cooperation instruments. (orig.)

  16. Imaging instrument for positron emitting heavy ion beam injection

    International Nuclear Information System (INIS)

    Llacer, J.; Chatterjee, A.; Jackson, H.C.; Lin, J.C.; Zunzunegui, M.V.

    1978-10-01

    The design and performance of an instrument for the imaging of coincidence annihilation gamma rays emitted from the end point of the trajectories of radioactive high-energy heavy ions is described. The positron-emitting heavy ions are the result of nuclear fragmentation of accelerated heavy ions used in cancer therapy or diagnostic medicine. The instrument constructed is capable of locating the ion beam trajectory end point within 1 mm for an injected activity of 200 nanoCi in a measurement time of 1 sec in some favorable conditions. Limited imaging in three dimensions is also demonstrated

  17. [Diagnostics of work motivation (DIAMO): optimization and construct validity].

    Science.gov (United States)

    Ranft, Andreas; Fiedler, Rolf; Greitemann, Bernhard; Heuft, Gereon

    2009-01-01

    Faced with increasing cost pressure of the social insurance system the carriers of rehabilitation programs focus on the efficacy of their measures. The diagnostic instrument for work motivation (DIAMO) has been developed to assess the influence of job-related motivation on the rehabilitation outcome. The inner structure of the instrument was validated and optimized in a cohort of medical rehabilitation patients (n = 422). Construct validity was further tested by using established instruments. Ten scales related to self-image, intention of action and goodness of fit show good psychometric qualities (Cronbachs alpha: 0.72 - 0.86). The constructs correlate moderately-to-strongly with personality-oriented scales while correlation with disease-related contents is low. The DIAMO is a generic and not disease oriented instrument. It would be expected to facilitate the development of vocational interventions to increase the rehabilitation outcome.

  18. Vaccum and beam diagnostic controls for ORIC beam lines

    International Nuclear Information System (INIS)

    Tatum, B.A.

    1991-01-01

    Vacuum and beam diagnostic equipment on beam lines from the Oak Ridge Isochronous Cyclotron, ORIC, is now controlled by a new dedicated system. The new system is based on an industrial programmable logic controller with an IBM AT personal computer providing control room operator interface. Expansion of this system requires minimal reconfiguration and programming, thus facilitating the construction of additional beam lines. Details of the implementation, operation, and performance of the system are discussed. 2 refs., 2 figs

  19. Group fellowship training in nuclear spectroscopy instrumentation maintenance at the Seibersdorf Laboratories

    International Nuclear Information System (INIS)

    Xie, Y.; Abdel-Rassoul, A.A.

    1989-01-01

    Nuclear spectroscopy instruments are important tools for nuclear research and applications. Several types of nuclear spectrometers are being sent to numerous laboratories in developing countries through technical co-operation projects. These are mostly sophisticated systems based on different radiation detectors, analogue and digital circuitry. In most cases, they use microprocessor or computer techniques involving software and hardware. Maintenance service and repair of these systems is a major problem in many developing countries because suppliers do not set up service stations. The Agency's Laboratories at Seibersdorf started conducting group fellowship training on nuclear spectroscopy instrumentation maintenance in 1987. This article describes the training programme

  20. A Smart Mobile Lab-on-Chip-Based Medical Diagnostics System Architecture Designed For Evolvability

    DEFF Research Database (Denmark)

    Patou, François; Dimaki, Maria; Svendsen, Winnie Edith

    2015-01-01

    for this work. We introduce a smart-mobile and LoC-based system architecture designed for evolvability. By propagating LoC programmability, instrumentation, and control tools to the highlevel abstraction smart-mobile software layer, our architecture facilitates the realisation of new use...

  1. Data and Analysis from a Time-Resolved Tomographic Optical Beam Diagnostic

    International Nuclear Information System (INIS)

    Frayer, Daniel K.; Johnson, Douglas; Ekdahl, Carl

    2010-01-01

    An optical tomographic diagnostic instrument developed for the acquisition of high-speed time-resolved images has been fielded at the Dual-Axis Radiographic Hydrodynamic Test (DARHT) Facility at Los Alamos National Laboratory. The instrument was developed for the creation of time histories of electron-beam cross section through the collection of Cerenkov light. Four optical lines of sight optically collapse an image and relay projections via an optical fiber relay to recording instruments; a tomographic reconstruction algorithm creates the time history. Because the instrument may be operated in an adverse environment, it may be operated, adjusted, and calibrated remotely. The instrument was operated over the course of various activities during and after DARHT commissioning, and tomographic reconstructions reported verifiable beam characteristics. Results from the collected data and reconstructions and analysis of the data are discussed.

  2. High-throughput gated photon counter with two detection windows programmable down to 70 ps width

    Energy Technology Data Exchange (ETDEWEB)

    Boso, Gianluca; Tosi, Alberto, E-mail: alberto.tosi@polimi.it; Zappa, Franco [Dipartimento di Elettronica, Informazione e Bioingegneria, Politecnico di Milano, Piazza Leonardo Da Vinci 32, 20133 Milano (Italy); Mora, Alberto Dalla [Dipartimento di Fisica, Politecnico di Milano, Piazza Leonardo Da Vinci 32, 20133 Milano (Italy)

    2014-01-15

    We present the design and characterization of a high-throughput gated photon counter able to count electrical pulses occurring within two well-defined and programmable detection windows. We extensively characterized and validated this instrument up to 100 Mcounts/s and with detection window width down to 70 ps. This instrument is suitable for many applications and proves to be a cost-effective and compact alternative to time-correlated single-photon counting equipment, thanks to its easy configurability, user-friendly interface, and fully adjustable settings via a Universal Serial Bus (USB) link to a remote computer.

  3. High-throughput gated photon counter with two detection windows programmable down to 70 ps width

    International Nuclear Information System (INIS)

    Boso, Gianluca; Tosi, Alberto; Zappa, Franco; Mora, Alberto Dalla

    2014-01-01

    We present the design and characterization of a high-throughput gated photon counter able to count electrical pulses occurring within two well-defined and programmable detection windows. We extensively characterized and validated this instrument up to 100 Mcounts/s and with detection window width down to 70 ps. This instrument is suitable for many applications and proves to be a cost-effective and compact alternative to time-correlated single-photon counting equipment, thanks to its easy configurability, user-friendly interface, and fully adjustable settings via a Universal Serial Bus (USB) link to a remote computer

  4. Energy economics basics - Emphasis programme 2004 - 2007; Schwerpunktprogramm EWG 2004 bis 2007

    Energy Technology Data Exchange (ETDEWEB)

    Gutzwiller, L.

    2005-07-01

    This report from the Swiss Federal Office of Energy (SFOE) examines the work done within the framework of the interdisciplinary energy economics programme on scenarios and instruments for energy policy-making and economics, as well as on social and environmental aspects. The report reviews the emphasis and goals of the next phase of the programme for the period 2004 - 2007. A research road map is discussed that is to identify promising technologies that will provide a substantial contribution to meeting the goal of creating the so-called '2000-Watt Society'. The road map is to also help identify technologies that provide socio-economic advantages and identify bottlenecks and restraints on the propagation of energy-efficient technologies in the building and transport areas.

  5. Reliability of Instruments Measuring At-Risk and Problem Gambling Among Young Individuals

    DEFF Research Database (Denmark)

    Edgren, Robert; Castrén, Sari; Mäkelä, Marjukka

    2016-01-01

    This review aims to clarify which instruments measuring at-risk and problem gambling (ARPG) among youth are reliable and valid in light of reported estimates of internal consistency, classification accuracy, and psychometric properties. A systematic search was conducted in PubMed, Medline, and Psyc......Info covering the years 2009–2015. In total, 50 original research articles fulfilled the inclusion criteria: target age under 29 years, using an instrument designed for youth, and reporting a reliability estimate. Articles were evaluated with the revised Quality Assessment of Diagnostic Accuracy Studies tool....... Reliability estimates were reported for five ARPG instruments. Most studies (66%) evaluated the South Oaks Gambling Screen Revised for Adolescents. The Gambling Addictive Behavior Scale for Adolescents was the only novel instrument. In general, the evaluation of instrument reliability was superficial. Despite...

  6. Flexible human machine interface for process diagnostics

    International Nuclear Information System (INIS)

    Reifman, J.; Graham, G.E.; Wei, T.Y.C.; Brown, K.R.; Chin, R.Y.

    1996-01-01

    A flexible human machine interface to design and display graphical and textual process diagnostic information is presented. The system operates on different computer hardware platforms, including PCs under MS Windows and UNIX Workstations under X-Windows, in a client-server architecture. The interface system is customized for specific process applications in a graphical user interface development environment by overlaying the image of the process piping and instrumentation diagram with display objects that are highlighted in color during diagnostic display. Customization of the system is presented for Commonwealth Edison's Braidwood PWR Chemical and Volume Control System with transients simulated by a full-scale operator-training simulator and diagnosed by a computer-based system

  7. Advanced Laser-Based Techniques for Gas-Phase Diagnostics in Combustion and Aerospace Engineering.

    Science.gov (United States)

    Ehn, Andreas; Zhu, Jiajian; Li, Xuesong; Kiefer, Johannes

    2017-03-01

    Gaining information of species, temperature, and velocity distributions in turbulent combustion and high-speed reactive flows is challenging, particularly for conducting measurements without influencing the experimental object itself. The use of optical and spectroscopic techniques, and in particular laser-based diagnostics, has shown outstanding abilities for performing non-intrusive in situ diagnostics. The development of instrumentation, such as robust lasers with high pulse energy, ultra-short pulse duration, and high repetition rate along with digitized cameras exhibiting high sensitivity, large dynamic range, and frame rates on the order of MHz, has opened up for temporally and spatially resolved volumetric measurements of extreme dynamics and complexities. The aim of this article is to present selected important laser-based techniques for gas-phase diagnostics focusing on their applications in combustion and aerospace engineering. Applicable laser-based techniques for investigations of turbulent flows and combustion such as planar laser-induced fluorescence, Raman and Rayleigh scattering, coherent anti-Stokes Raman scattering, laser-induced grating scattering, particle image velocimetry, laser Doppler anemometry, and tomographic imaging are reviewed and described with some background physics. In addition, demands on instrumentation are further discussed to give insight in the possibilities that are offered by laser flow diagnostics.

  8. Quality control of conventional diagnostic radiology equipment in Serbia and Montenegro

    International Nuclear Information System (INIS)

    Ciraj, O.; Kosutic, D.; Markovic, S.

    2003-01-01

    There are more than 1500 diagnostic X-ray tubes in service in Serbia and Montenegro. Diagnostic X-ray equipment is checked on annual basis. X-ray equipment Qc protocols have been adopted from several international standards and guidelines [1,2], which have been modified according our practice and measuring equipment. According our inventory, about one half of all installed units is used for conventional X-ray diagnostics, 10% are mobile units, 2% of all in units in operation are mammographic devices an another 2% are computed tomography units. In addition there are about 600 dental X-ray units, which is 36% of all units. It is worth mentioning that almost 30 % of all installed units have single-phase generators, another 25% are tree phase (six and twelve pulse) generators and nearly 9% are high frequency units. Majority of units was installed more than 25 years ago. The Quality Control (QC) in radiography is a central part of QA programme, which deals with equipment maintenance and monitoring. QA in diagnostic radiology is a mean of maintaining standards in imaging and working towards minimizing patient and staff doses. As a part of QA programme in diagnostic radiology, the performance characteristics of 96 conventional X-ray units were measured in six months period during 2003. The diagnostic units were located in hospitals all over the country. They represent 25% of the total conventional diagnostic units of the country. About one half of measured X-ray units were new-installed. QC program has positive effect on X-ray equipment performance in a period of a few years. It is essential to perform QC tests for all installed X-ray units at least on annual basis. This would lead to production of consistent X-ray images, with minimal retake rate and hence, will contribute to decreasing of the patient dose. Patient doses are determined by multitude factors which interact in very complicated manner. It is very important to perform real patient dose measurements in

  9. Complex programmable logic device based alarm sequencer for nuclear power plants

    International Nuclear Information System (INIS)

    Khedkar, Ravindra; Solomon, J. Selva; KrishnaKumar, B.

    2001-01-01

    Complex Programmable Logic Device based Alarm Sequencer is an instrument, which detects alarms, memorizes them and displays the sequences of occurrence of alarms. It caters to sixteen alarm signals and distinguishes the sequence among any two alarms with a time resolution of 1 ms. The system described has been designed for continuous operation in process plants, nuclear power plants etc. The system has been tested and found to be working satisfactorily. (author)

  10. A new kind of user interface for controlling MFTF diagnostics

    International Nuclear Information System (INIS)

    Preckshot, G.; Mead, J.; Saroyan, R.

    1983-01-01

    The Mirror Fusion Test Facility (MFTF) at Lawrence Livermore National Laboratory is faced with the problem of controlling a multitude of plasma diagnostics instruments from a central, multiprocessor computer facility. A 16-bit microprocessor-based workstation allows each physicist entree into the central multiprocessor, which consists of nine Perkin-Elmer 32-bit minicomputers. The workstation provides the user interface to the larger system, with display graphics, windowing, and a physics notebook. Controlling a diagnostic is now equivalent to making entries into a traditional physics notebook

  11. The evaluation of a rapid in situ HIV confirmation test in a programme with a high failure rate of the WHO HIV two-test diagnostic algorithm.

    Directory of Open Access Journals (Sweden)

    Derryck B Klarkowski

    Full Text Available BACKGROUND: Concerns about false-positive HIV results led to a review of testing procedures used in a Médecins Sans Frontières (MSF HIV programme in Bukavu, eastern Democratic Republic of Congo. In addition to the WHO HIV rapid diagnostic test algorithm (RDT (two positive RDTs alone for HIV diagnosis used in voluntary counselling and testing (VCT sites we evaluated in situ a practical field-based confirmation test against western blot WB. In addition, we aimed to determine the false-positive rate of the WHO two-test algorithm compared with our adapted protocol including confirmation testing, and whether weakly reactive compared with strongly reactive rapid test results were more likely to be false positives. METHODOLOGY/PRINCIPAL FINDINGS: 2864 clients presenting to MSF VCT centres in Bukavu during January to May 2006 were tested using Determine HIV-1/2 and UniGold HIV rapid tests in parallel by nurse counsellors. Plasma samples on 229 clients confirmed as double RDT positive by laboratory retesting were further tested using both WB and the Orgenics Immunocomb Combfirm HIV confirmation test (OIC-HIV. Of these, 24 samples were negative or indeterminate by WB representing a false-positive rate of the WHO two-test algorithm of 10.5% (95%CI 6.6-15.2. 17 of the 229 samples were weakly positive on rapid testing and all were negative or indeterminate by WB. The false-positive rate fell to 3.3% (95%CI 1.3-6.7 when only strong-positive rapid test results were considered. Agreement between OIC-HIV and WB was 99.1% (95%CI 96.9-99.9% with no false OIC-HIV positives if stringent criteria for positive OIC-HIV diagnoses were used. CONCLUSIONS: The WHO HIV two-test diagnostic algorithm produced an unacceptably high level of false-positive diagnoses in our setting, especially if results were weakly positive. The most probable causes of the false-positive results were serological cross-reactivity or non-specific immune reactivity. Our findings show that the OIC

  12. Diagnosing Autism Spectrum Disorders in Adults: The Use of Autism Diagnostic Observation Schedule (ADOS) Module 4

    Science.gov (United States)

    Bastiaansen, Jojanneke A.; Meffert, Harma; Hein, Simone; Huizinga, Petra; Ketelaars, Cees; Pijnenborg, Marieke; Bartels, Arnold; Minderaa, Ruud; Keysers, Christian; de Bildt, Annelies

    2011-01-01

    Autism Diagnostic Observation Schedule (ADOS) module 4 was investigated in an independent sample of high-functioning adult males with an autism spectrum disorder (ASD) compared to three specific diagnostic groups: schizophrenia, psychopathy, and typical development. ADOS module 4 proves to be a reliable instrument with good predictive value. It…

  13. Does a pre-treatment diagnostic interview affect the outcome of internet-based self-help for social anxiety disorder? a randomized controlled trial.

    Science.gov (United States)

    Boettcher, Johanna; Berger, Thomas; Renneberg, Babette

    2012-10-01

    Numerous studies suggest that Internet-based self-help treatments are effective in treating anxiety disorders. Trials evaluating such interventions differ in their screening procedures and in the amount of clinician contact in the diagnostic assessment phase. The present study evaluates the impact of a pre-treatment diagnostic interview on the outcome of an Internet-based treatment for Social Anxiety Disorder (SAD). One hundred and nine participants seeking treatment for SAD were randomized to either an interview-group (IG, N = 53) or to a non-interview group (NIG, N = 56). All participants took part in the same 10-week cognitive-behavioural unguided self-help programme. Before receiving access to the programme, participants of the IG underwent a structured diagnostic interview. Participants of the NIG started directly with the programme. Participants in both groups showed significant and substantial improvement on social anxiety measures from pre- to post-assessment (d IG = 1.30-1.63; d NIG = 1.00-1.28) and from pre- to 4-month follow-up assessment (d IG = 1.38-1.87; d NIG = 1.10-1.21). Significant between-groups effects in favour of the IG were found on secondary outcome measures of depression and general distress (d = 0.18-0.42). These findings suggest that Internet-based self-help is effective in treating SAD, whether or not a diagnostic interview is involved. However, the pre-treatment interview seems to facilitate change on secondary outcomes such as depression and general distress.

  14. Evolution of the VLT instrument control system toward industry standards

    Science.gov (United States)

    Kiekebusch, Mario J.; Chiozzi, Gianluca; Knudstrup, Jens; Popovic, Dan; Zins, Gerard

    2010-07-01

    The VLT control system is a large distributed system consisting of Linux Workstations providing the high level coordination and interfaces to the users, and VME-based Local Control Units (LCU's) running the VxWorks real-time operating system with commercial and proprietary boards acting as the interface to the instrument functions. After more than 10 years of VLT operations, some of the applied technologies used by the astronomical instruments are being discontinued making it difficult to find adequate hardware for future projects. In order to deal with this obsolescence, the VLT Instrumentation Framework is being extended to adopt well established Commercial Off The Shelf (COTS) components connected through industry standard fieldbuses. This ensures a flexible state of the art hardware configuration for the next generation VLT instruments allowing the access to instrument devices via more compact and simpler control units like PC-based Programmable Logical Controllers (PLC's). It also makes it possible to control devices directly from the Instrument Workstation through a normal Ethernet connection. This paper outlines the requirements that motivated this work, as well as the architecture and the design of the framework extension. In addition, it describes the preliminary results on a use case which is a VLTI visitor instrument used as a pilot project to validate the concepts and the suitability of some COTS products like a PC-based PLCs, EtherCAT8 and OPC UA6 as solutions for instrument control.

  15. Intraoral fiber optic-based diagnostic for periodontal disease

    Energy Technology Data Exchange (ETDEWEB)

    Johnson, P W; Gutierrez, D M; Everett, M J; Brown, S B; Langry, K C; Colston, B W; Roe, J N

    2000-01-21

    The purpose of this initial study was to begin development of a new, objective diagnostic instrument that will allow simultaneous quantitation of multiple proteases within a single periodontal pocket using a chemical fiber optic sensor. This approach could potentially be adapted to use specific antibodies and chemiluminescence to detect and quantitate virtually any compound and compare concentrations of different compounds within the same periodontal pocket. The device could also be used to assay secretions in salivary ducts or from a variety of wounds. The applicability is, therefore, not solely limited to dentistry and the device would be important both for clinical diagnostics and as a research tool.

  16. Intraoral fiber-optic-based diagnostic for periodontal disease

    Science.gov (United States)

    Colston, Bill W., Jr.; Gutierrez, Dora M.; Everett, Matthew J.; Brown, Steve B.; Langry, Kevin C.; Cox, Weldon R.; Johnson, Paul W.; Roe, Jeffrey N.

    2000-05-01

    The purpose of this initial study was to begin development of a new, objective diagnostic instrument that will allow simultaneous quantitation of multiple proteases within a single periodontal pocket using a chemical fiber optic senor. This approach could potentially be adapted to use specific antibodies and chemiluminescence to detect and quantitate virtually any compound and compare concentrations of different compounds within the same periodontal pocket. The device could also be used to assay secretions in salivary ducts or from a variety of wounds. The applicability is, therefore, not solely limited to dentistry and the device would be important both for clinical diagnostics and as a research too.

  17. High mortality during tuberculosis treatment does not indicate long diagnostic delays in Vietnam: a cohort study

    Directory of Open Access Journals (Sweden)

    Sy Dinh N

    2007-08-01

    Full Text Available Abstract Background Delay in tuberculosis diagnosis and treatment initiation may increase disease severity and mortality. In evaluations of tuberculosis control programmes high fatality rates during tuberculosis treatment, are used as an indicator of long delays in low HIV-prevalence settings. However, data for this presumed association between delay and fatality are lacking. We assessed the association between diagnostic delay and mortality of new smear-positive pulmonary tuberculosis patients in Vietnam. Methods Follow-up of a patient cohort included in a survey of diagnostic delay in 70 randomly selected districts. Data on diagnosis and treatment were extracted from routine registers. Patients who had died during the course of treatment were compared to those with reported cure, completed treatment or failure (survivors. Results Complete data were available for 1881/2093 (89.9% patients, of whom 82 (4.4% had died. Fatality was 4.5% for patients with ≤ 4 weeks delay, 5.0% for 5- ≤ 8 weeks delay (aOR 1.11, 95%CI 0.67–1.84 and 3.2% for > 9 weeks delay (aOR 0.69, 95%CI 0.37–1.30. Fatality tended to decline with increasing delay but this was not significant. Fatality was not associated with median diagnostic delay at district level (Spearman's rho = -0.08, P = 0.5. Conclusion Diagnostic delay is not associated with treatment mortality in Vietnam at individual nor district level, suggesting that high case fatality should not be used as an indicator of long diagnostic delay in national tuberculosis programmes.

  18. Automated Calibration of Dosimeters for Diagnostic Radiology

    International Nuclear Information System (INIS)

    Romero Acosta, A.; Gutierrez Lores, S.

    2015-01-01

    Calibration of dosimeters for diagnostic radiology includes current and charge measurements, which are often repetitive. However, these measurements are usually done using modern electrometers, which are equipped with an RS-232 interface that enables instrument control from a computer. This paper presents an automated system aimed to the measurements for the calibration of dosimeters used in diagnostic radiology. A software application was developed, in order to achieve the acquisition of the electric charge readings, measured values of the monitor chamber, calculation of the calibration coefficient and issue of a calibration certificate. A primary data record file is filled and stored in the computer hard disk. The calibration method used was calibration by substitution. With this system, a better control over the calibration process is achieved and the need for human intervention is reduced. the automated system will be used in the calibration of dosimeters for diagnostic radiology at the Cuban Secondary Standard Dosimetry Laboratory of the Center for Radiation Protection and Hygiene. (Author)

  19. Diagnostic nuclear medicine. 2. rev. ed.

    International Nuclear Information System (INIS)

    Schiepers, C.

    2006-01-01

    The field of nuclear medicine is undergoing rapid expansion, and is evolving into diagnostic molecular imaging. During recent years, dual-modality imaging with PET/CT has gained acceptance and this is currently the fastest-growing technique for oncological imaging applications. The glucose analogue FDG has held its place in diagnostic oncology, assessment of myocardial viability and diagnosis of neuro-degenerative disorders. Peptides have become even more important as imaging agents. The accuracy of hepatobiliary scintigraphy has been enhanced by cholecystokinin. The use of ACE inhibitors in the evaluation of renovascular hypertension has become the standard in renography. New instrumentation has led to faster scanners, and computer development to better image processing software. Automatic processing is more common, and standardization of protocols can be accomplished easily. The field of gene imaging has progressed, although routine clinical applications are not yet available. The present text, supplemented with many detailed and informative illustrations, represents an adjunct to the standard knowledge of diagnostic nuclear medicine and provides both the student and the professional with an overview of developments during the past decade. (orig.)

  20. Overview of the CERN Linac4 beam instrumentation

    CERN Document Server

    Roncarolo, F; Bravin, E; Dehning, B; Duraffourg, M; Gerard, D; Holzer, E B; Lenardon, F; Focker, G; Raich, U; Soby, L; Sordet, M; Tan, J; Tranquille, G; Vuitton, C; Zamantzas, C; Cheymol, B

    2010-01-01

    The CERN LINAC4 will represent the first upgrade of the LHC injection chain, by accelerating H- ions from 45 KeV to 160 MeV for charge-exchange injection into the PS Booster. In order to provide its safe and efficient commissioning and operation, a wide variety of beam diagnostics devices has been designed for installation at convenient locations all over the accelerator length and in the transfer line to the PS Booster. This paper gives an overview of all instrumentation devices, including those to measure beam position, transverse and longitudinal profile, beam current and beam loss. The well advanced status of the system design and the main instrument features are discussed

  1. Diagnostic Criteria for Temporomandibular Disorders (DC/TMD) for Clinical and Research Applications: recommendations of the International RDC/TMD Consortium Network* and Orofacial Pain Special Interest Group†.

    Science.gov (United States)

    Schiffman, Eric; Ohrbach, Richard; Truelove, Edmond; Look, John; Anderson, Gary; Goulet, Jean-Paul; List, Thomas; Svensson, Peter; Gonzalez, Yoly; Lobbezoo, Frank; Michelotti, Ambra; Brooks, Sharon L; Ceusters, Werner; Drangsholt, Mark; Ettlin, Dominik; Gaul, Charly; Goldberg, Louis J; Haythornthwaite, Jennifer A; Hollender, Lars; Jensen, Rigmor; John, Mike T; De Laat, Antoon; de Leeuw, Reny; Maixner, William; van der Meulen, Marylee; Murray, Greg M; Nixdorf, Donald R; Palla, Sandro; Petersson, Arne; Pionchon, Paul; Smith, Barry; Visscher, Corine M; Zakrzewska, Joanna; Dworkin, Samuel F

    2014-01-01

    The original Research Diagnostic Criteria for Temporomandibular Disorders (RDC/TMD) Axis I diagnostic algorithms have been demonstrated to be reliable. However, the Validation Project determined that the RDC/TMD Axis I validity was below the target sensitivity of ≥ 0.70 and specificity of ≥ 0.95. Consequently, these empirical results supported the development of revised RDC/TMD Axis I diagnostic algorithms that were subsequently demonstrated to be valid for the most common pain-related TMD and for one temporomandibular joint (TMJ) intra-articular disorder. The original RDC/TMD Axis II instruments were shown to be both reliable and valid. Working from these findings and revisions, two international consensus workshops were convened, from which recommendations were obtained for the finalization of new Axis I diagnostic algorithms and new Axis II instruments. Through a series of workshops and symposia, a panel of clinical and basic science pain experts modified the revised RDC/TMD Axis I algorithms by using comprehensive searches of published TMD diagnostic literature followed by review and consensus via a formal structured process. The panel's recommendations for further revision of the Axis I diagnostic algorithms were assessed for validity by using the Validation Project's data set, and for reliability by using newly collected data from the ongoing TMJ Impact Project-the follow-up study to the Validation Project. New Axis II instruments were identified through a comprehensive search of the literature providing valid instruments that, relative to the RDC/TMD, are shorter in length, are available in the public domain, and currently are being used in medical settings. The newly recommended Diagnostic Criteria for TMD (DC/TMD) Axis I protocol includes both a valid screener for detecting any pain-related TMD as well as valid diagnostic criteria for differentiating the most common pain-related TMD (sensitivity ≥ 0.86, specificity ≥ 0.98) and for one intra

  2. Neural network analysis of vibration signals in the diagnostics of ...

    African Journals Online (AJOL)

    The article is devoted to the improvement of heat network calculation and diagnostics methods. Currently used instruments have many shortcomings for the diagnosis of pipelines, including low reliability of defect detection and subjective decision-making. The authors created an experimental stand, which allows to conduct ...

  3. Optical diagnostics of streamer discharges in atmospheric gases

    Czech Academy of Sciences Publication Activity Database

    Šimek, Milan

    2014-01-01

    Roč. 47, č. 46 (2014), s. 463001-463001 ISSN 0022-3727 R&D Projects: GA ČR(CZ) GAP205/12/1709 Grant - others:Rada Programu interní podpory projektů mezinárodní spolupráce AV ČR(CZ) M100431201 Program:M Institutional support: RVO:61389021 Keywords : streamer * optical diagnostics * laser-induced fluorescence * LIF * TALIF * red-sprite Subject RIV: BL - Plasma and Gas Discharge Physics Impact factor: 2.721, year: 2014 http://iopscience.iop.org/0022-3727/47/46/463001/pdf/0022-3727_47_46_463001.pdf

  4. Highlights of the UKAEA Underlying Research Programme: April 1988-March 1989

    International Nuclear Information System (INIS)

    1990-01-01

    Investment in fundamental research is essential to the success of any organisation whose business is the selling of research and development and the services relating to it. The resulting scientific and technical excellence is the hall-mark of a major contract research and development organisation and its main product. Fundamental research in the AEA is co-ordinated through the Underlying Research Programme. The Programme has to keep closely in touch with all the applied projects, in order to identify within these the problems that are hindering progress and might therefore benefit from further investigation. It also has the responsibility for developing new skills and techniques across the AEA. This brochure highlights some of the projects undertaken as part of the Underlying Research Programme. The Programme is organised into fifteen different areas of research, with the research projects not obviously fitting into any of these areas having a separate section to themselves. The text introduces each of these areas in turn, and then describes two or three examples of the sort of work undertaken within it. The areas are radiation effects, fracture studies, chemical effects at surfaces, surface physics and corrosion, fluid mechanics and heat transfer, nuclear studies, neutron beam studies, theoretical sciences, instrumentation, reactor physics and control, fabrication processes, laser isotope separation, nuclear fuel cycle studies, quantum electronics and radiological protection. (author)

  5. Postgraduate Medical Physics Academic Programmes. Endorsed by the International Organization for Medical Physics (IOMP)

    International Nuclear Information System (INIS)

    2013-01-01

    The safe and effective implementation of technology in radiation medicine requires expert medical physics support. In order to fulfil their duties, medical physicists working as health professionals should demonstrate competency in their area of specialization by obtaining the appropriate educational qualification and clinical competency training in one or more aspects of medical physics. At the international level, there are very few established, accredited academic education programmes for medical physics students, and no international guidelines exist which provide the recommended requirements, outline and structure of such a programme. An increasing number of Member States with a 'critical mass' of medical physicists are seeking support to initiate their own national postgraduate education programmes. This publication, therefore, seeks to provide guidelines for the establishment of a postgraduate academic education programme in medical physics, which could also be used to achieve harmonized standards of competence worldwide. This publication was developed in support of the internationally harmonized guidelines given in IAEA Human Health Series No. 25 on the requirements for academic education and clinical training of clinically qualified medical physicists. In addition to academic education, medical physicists should obtain specialized clinical training. The IAEA has published three Training Course Series publications with accompanying handbooks, which provide guidelines and references to training material for clinical training programmes for medical physicists specializing in radiation oncology (TCS-37), diagnostic radiology (TCS-47) and nuclear medicine (TCS-50)

  6. A review of the U.K. fast reactor programme: March 1978

    Energy Technology Data Exchange (ETDEWEB)

    Smith, R D [United Kingdom Atomic Energy Authority, Risley (United Kingdom)

    1978-07-01

    The review of the UK fast reactor programme covers the description of Dounreay Fast Reactor shut down after seventeen years of successful operation; description of prototype fast reactor (PFR); core design parameters safety features and plant design for commercial demonstration fast reactor (CDFR). Engineering development is related to large sodium rigs, coolant circuit hydraulics and vibration, instrumentation and components. The subjects of interest are material development, sodium technology, fast reactor fuel, fuel cycle, reactor safety, reactor performance studies.

  7. A review of the U.K. fast reactor programme: March 1978

    International Nuclear Information System (INIS)

    Smith, R.D.

    1978-01-01

    The review of the UK fast reactor programme covers the description of Dounreay Fast Reactor shut down after seventeen years of successful operation; description of prototype fast reactor (PFR); core design parameters safety features and plant design for commercial demonstration fast reactor (CDFR). Engineering development is related to large sodium rigs, coolant circuit hydraulics and vibration, instrumentation and components. The subjects of interest are material development, sodium technology, fast reactor fuel, fuel cycle, reactor safety, reactor performance studies

  8. The need for theory evaluation in global citizenship programmes: The case of the GCSA programme.

    Science.gov (United States)

    Goodier, Sarah; Field, Carren; Goodman, Suki

    2018-02-01

    Many education programmes lack a documented programme theory. This is a problem for programme planners and evaluators as the ability to measure programme success is grounded in the plausibility of the programme's underlying causal logic. Where the programme theory has not been documented, conducting a theory evaluation offers a foundational evaluation step as it gives an indication of whether the theory behind a programme is sound. This paper presents a case of a theory evaluation of a Global Citizenship programme at a top-ranking university in South Africa, subsequently called the GCSA Programme. This evaluation highlights the need for documented programme theory in global citizenship-type programmes for future programme development. An articulated programme theory produced for the GCSA Programme, analysed against the available social science literature, indicated it is comparable to other such programmes in terms of its overarching framework. What the research found is that most other global citizenship programmes do not have an articulated programme theory. These programmes also do not explicitly link their specific activities to their intended outcomes, making demonstrating impact impossible. In conclusion, we argue that taking a theory-based approach can strengthen and enable outcome evaluations in global citizenship programmes. Copyright © 2017. Published by Elsevier Ltd.

  9. Developing and implementing an anti-corruption ethics and compliance programme in the African environment

    Directory of Open Access Journals (Sweden)

    Alain Ndedi

    2015-12-01

    Full Text Available This article discusses the development and implementation of anti-corruption ethics and compliance programme in the African business environment. In the past decade, an international legal framework has been developed to tackle corruption both in public and private sectors. This framework includes the United Nations Convention against Corruption (UNCAC, which entered into force in 2005, and the Convention on Combating Bribery of Foreign Public Officials in International Business Transactions, which entered into force in 1999. These instruments mandate that State Parties must criminalise and punish a variety of corrupt practices. Relevant domestic laws have a direct impact on business, especially in States Parties instruments that require the establishment of liability of legal persons for corrupt acts. The African Union Convention also requires States Parties to establish mechanisms to encourage participation by the private sector in the fight against unfair competition, respect of the tender procedures and property rights. The paper details various steps needed to efficiently and effectively implement anti-corruption ethics and compliance programme in the African context. The first part of the paper develops the primary objective of the corruption risk assessment which is to better understand the risk exposure so that informed risk management decisions may be taken. A structured approach for how enterprises could conduct an anti-corruption risk assessment will be outlined in this first section. The author argued in this same first section that each enterprise’s own risk assessment exercise is unique, depending on that enterprise’s industry, size, location, and other factors inherent to that organisation. The second part of the paper drafts the development and the implementation of an anti-corruption programme. The paper concludes by stating that an anti-corruption and compliance programme is not a panacea for fighting all the ills on

  10. Fewer re-admissions and bed days following an intensive transitional post-discharge aftercare programme for a mixed diagnostic group of patients

    DEFF Research Database (Denmark)

    Nilsson, Maria; Mir, Shazia; Larsen, Jens Knud

    2014-01-01

    was used to compare the groups. RESULTS: The majority of patients in both groups suffered from affective disorders, followed by personality disorders and a small number of other psychiatric diagnoses. Service use in the TA group was lower than in the RC group with fewer bed days after 10 weeks (P = 0...... service use in the TA programme group is in line with day treatment programme research for patients with affective disorders.......BACKGROUND: The organization of aftercare is important for a successful outcome; still the optimal organization has not been fully explored. An intensive transitional post-discharge aftercare (TA) programme, for a mixed group of non-psychotic patients, was recently developed. Patients with non...

  11. Promoting interdisciplinary education − the Vienna Doctoral Programme on Water Resource Systems

    Directory of Open Access Journals (Sweden)

    W. Wagner

    2012-02-01

    Full Text Available The Vienna Doctoral Programme on Water Resource Systems (DK-WRS is a programme that aims to educate students in interdisciplinary water science through cutting edge research at an international level. It is funded by the Austrian Science Fund and designed to run over a period of 12 yr during which 80 doctoral students are anticipated to graduate. This paper reports on our experiences of setting up and implementing the Programme. We identify three challenges: integrating the disciplines, maintaining depth in an interdisciplinary programme, and teaching subjects remote to each student's core expertise. To address these challenges we adopt a number of approaches. We use three levels of instruments to foster integration across the disciplines: joint groups (e.g. a joint study programme, joint science questions (e.g. developed in annual symposia, and joint study sites. To maintain depth we apply a system of quality control including regular feedback sessions, theses by journal publications and international study exchange. For simultaneously teaching students from civil and environmental engineering, biology, geology, chemistry, mathematics we use visually explicit teaching, learning by doing, extra mentoring and by cross relating associated subjects. Our initial assessment of the Programme shows some very positive outcomes. Joint science questions formed between students from various disciplines indicate integration is being achieved. The number of successful publications in top journals suggests that depth is maintained. Positive feedback from the students on the variety and clarity of the courses indicates the teaching strategy is working well. Our experiences have shown that implementing and running an interdisciplinary doctoral programme has its challenges and is demanding in terms of time and human resources but seeing interactions progress and watching people grow and develop their way of thinking in an interdisciplinary environment is a

  12. RECENT BEAM MEASUREMENTS AND NEW INSTRUMENTATION AT THE ADVANCED LIGHT SOURCE

    International Nuclear Information System (INIS)

    Sannibale, Fernando; Baptiste, Kenneth; Barry, Walter; Chin, Michael; Filippetto, Daniele; Jaegerhofer, Lukas; Julian, James; Kwiatkowski, Slawomir; Low, Raymond; Plate, David; Portmann, Gregory; Robin, David; Scarvie, Tomas; Stupakov, Gennady; Weber, Jonah; Zolotorev, Max

    2008-01-01

    The Advanced Light Source (ALS) in Berkeley was the first of the soft x-ray third generation light source ever built, and since 1993 has been in continuous and successful operation serving a large community of users in the VUV and soft x-ray community. During these years the storage ring underwent through several important upgrades that allowed maintaining the performance of this veteran facility at the forefront. The ALS beam diagnostics and instrumentation have followed a similar path of innovation and upgrade and nowadays include most of the modem and last generation devices and technologies that are commercially available and used in the recently constructed third generation light sources. In this paper we will not focus on such already widely known systems, but we will concentrate our effort in the description of some measurements techniques, instrumentation and diagnostic systems specifically developed at the ALS and used during the last few years

  13. Programme documentation to control programme for Solar-tracker; Programdokumentation til styringsprogram til Solar-tracker

    Energy Technology Data Exchange (ETDEWEB)

    Rudbeck, C.

    1995-07-01

    The report contains the programme documentation partly for a programme to control of a tracking system and partly a programme, which uses this programme to make measurements of transmittance for covering layer. Both the transmittance measurement programme and the programme is built in Borland Pascal v7.0, and is compiled in Real mode for the use on a processor of the 80X86-family. The source code for the programme for transmittance measurements and the programmes (the positioning routines) are described in Appendix B. (EHS)

  14. Field programmable gate array reliability analysis using the dynamic flow graph methodology

    Energy Technology Data Exchange (ETDEWEB)

    McNelles, Phillip; Lu, Lixuan [Faculty of Energy Systems and Nuclear Science, University of Ontario Institute of Technology (UOIT), Ontario (Canada)

    2016-10-15

    Field programmable gate array (FPGA)-based systems are thought to be a practical option to replace certain obsolete instrumentation and control systems in nuclear power plants. An FPGA is a type of integrated circuit, which is programmed after being manufactured. FPGAs have some advantages over other electronic technologies, such as analog circuits, microprocessors, and Programmable Logic Controllers (PLCs), for nuclear instrumentation and control, and safety system applications. However, safety-related issues for FPGA-based systems remain to be verified. Owing to this, modeling FPGA-based systems for safety assessment has now become an important point of research. One potential methodology is the dynamic flowgraph methodology (DFM). It has been used for modeling software/hardware interactions in modern control systems. In this paper, FPGA logic was analyzed using DFM. Four aspects of FPGAs are investigated: the 'IEEE 1164 standard', registers (D flip-flops), configurable logic blocks, and an FPGA-based signal compensator. The ModelSim simulations confirmed that DFM was able to accurately model those four FPGA properties, proving that DFM has the potential to be used in the modeling of FPGA-based systems. Furthermore, advantages of DFM over traditional reliability analysis methods and FPGA simulators are presented, along with a discussion of potential issues with using DFM for FPGA-based system modeling.

  15. Recent developments of ECE diagnostics at JET

    Energy Technology Data Exchange (ETDEWEB)

    Luna, E. de la; Sanchez, J. [Association Euratom-Ciemat para Fusion, Ciemant (Spain); Cientoli, C.; Blanchard, P.; Joffrin, E.; Mazon, D. [Association Euratom-ENEA sulla Fusione, IFP-CNR, Milano (Italy); Riva, M.; Zerbini, M. [Association Euratom-ENEA sulla Fusione Centro Ricerche Energia Frascati (Italy); Conway, G. [IPP-Euratom Association, Garching (Germany); Felton, R.; Fessey, J.; Gowers, C. [Euratom/UKAEA Fusion Association, Culham Science Centre, Abingdon (United Kingdom); Murari, A. [Consorzio RFX, Association Euratom-ENEA sulla Fusione, Padova (Italy)

    2004-07-01

    In JET, two types of ECE (electron cyclotron emission) instruments are routinely operated to provide electron temperature measurements: a Michelson interferometer and a heterodyne radiometer. ECE diagnostics are able to provide time-resolved electron temperature profiles with high spatial and temporal resolution, and have proven to play a fundamental role in the investigation and development of internal transport barriers (ITBs) in JET. In this paper we report on the major upgrade of the ECE diagnostics systems currently in progress at JET. Diagnostic developments include an upgrade of the multi-channel heterodyne radiometer, aimed at extending the radial region over which T{sub e} measurement can be performed, and the installation of a new Michelson interferometer with fast scanning capability, to improve the frequency and temporal resolution of the multi-harmonic ECE measurements at JET. Moreover, a future extension of the ECE system, an oblique ECE diagnostic to measure the ECE spectra at different angles with respect to the normal to the magnetic field, is being developed. This diagnostic is expected to give valuable insight into the interpretation of ECE measurements in high T{sub e}-plasmas and should be available for measurements once JET resumes operation in 2005.In this paper, the recent developments in the JET ECE diagnostic system will be described and illustrated with some recent results, with an emphasis on issues related with calibration stability, high-Te plasmas and ITB studies. Some of these issues will be discussed in the context of ITER.

  16. An education and training programme for radiological institutes: impact on the reduction of the CT radiation dose

    International Nuclear Information System (INIS)

    Schindera, Sebastian T.; Allmen, Gabriel von; Vock, Peter; Szucs-Farkas, Zsolt; Treier, Reto; Trueb, Philipp R.; Nauer, Claude

    2011-01-01

    To establish an education and training programme for the reduction of CT radiation doses and to assess this programme's efficacy. Ten radiological institutes were counselled. The optimisation programme included a small group workshop and a lecture on radiation dose reduction strategies. The radiation dose used for five CT protocols (paranasal sinuses, brain, chest, pulmonary angiography and abdomen) was assessed using the dose-length product (DLP) before and after the optimisation programme. The mean DLP values were compared with national diagnostic reference levels (DRLs). The average reduction of the DLP after optimisation was 37% for the sinuses (180 vs. 113 mGycm, P < 0.001), 9% for the brain (982 vs. 896 mGycm, P < 0.05), 24% for the chest (425 vs. 322 mGycm, P < 0.05) and 42% for the pulmonary arteries (352 vs. 203 mGycm, P < 0.001). No significant change in DLP was found for abdominal CT. The post-optimisation DLP values of the sinuses, brain, chest, pulmonary arteries and abdomen were 68%, 10%, 20%, 55% and 15% below the DRL, respectively. The education and training programme for radiological institutes is effective in achieving a substantial reduction in CT radiation dose. (orig.)

  17. Fusion Programme SCK-CEN - Annual report 2009

    International Nuclear Information System (INIS)

    Massaut, V.

    2009-01-01

    This report summarizes the Research and Development work carried out at SCK-CEN on fusion technology in the year 2009. This covers mostly the work done under the EFDA agreement as well as the new developments carried out within the so-called Broader Approach of fusion such as - studies on structural and first wall materials for ITER and DEMO - studies and testing on the radiation resistance of instruments and componenets for the diagnostic and remote handling - development of irradiation devices and systems for the testing of fusion materials under representative environment.

  18. Fusion Programme SCK-CEN - Annual report 2009

    Energy Technology Data Exchange (ETDEWEB)

    Massaut, V

    2009-10-15

    This report summarizes the Research and Development work carried out at SCK-CEN on fusion technology in the year 2009. This covers mostly the work done under the EFDA agreement as well as the new developments carried out within the so-called Broader Approach of fusion such as - studies on structural and first wall materials for ITER and DEMO - studies and testing on the radiation resistance of instruments and componenets for the diagnostic and remote handling - development of irradiation devices and systems for the testing of fusion materials under representative environment.

  19. Innovative financing instruments for global health 2002–15: a systematic analysis

    Directory of Open Access Journals (Sweden)

    Prof Rifat Atun, FRCP

    2017-07-01

    Full Text Available Development assistance for health (DAH, the value of which peaked in 2013 and fell in 2015, is unlikely to rise substantially in the near future, increasing reliance on domestic and innovative financing sources to sustain health programmes in low-income and middle-income countries. We examined innovative financing instruments (IFIs—financing schemes that generate and mobilise funds—to estimate the quantum of financing mobilised from 2002 to 2015. We identified ten IFIs, which mobilised US$8·9 billion (2·3% of overall DAH in 2002–15. The funds generated by IFIs were channelled mostly through GAVI and the Global Fund, and used for programmes for new and underused vaccines, HIV/AIDS, malaria, tuberculosis, and maternal and child health. Vaccination programmes received the largest amount of funding ($2·6 billion, followed by HIV/AIDS ($1080·7 million and malaria ($1028·9 million, with no discernible funding targeted to non-communicable diseases.

  20. Diffusion of an e-learning programme among Danish General Practitioners: A nation-wide prospective survey

    Directory of Open Access Journals (Sweden)

    Nielsen Bente

    2008-04-01

    Full Text Available Abstract Background We were unable to identify studies that have considered the diffusion of an e-learning programme among a large population of general practitioners. The aim of this study was to investigate the uptake of an e-learning programme introduced to General Practitioners as part of a nation-wide disseminated dementia guideline. Methods A prospective study among all 3632 Danish GPs. The GPs were followed from the launching of the e-learning programme in November 2006 and 6 months forward. Main outcome measures: Use of the e-learning programme. A logistic regression model (GEE was used to identify predictors for use of the e-learning programme. Results In the study period, a total of 192 different GPs (5.3% were identified as users, and 17% (32 had at least one re-logon. Among responders at first login most have learnt about the e-learning programme from written material (41% or from the internet (44%. A total of 94% of the users described their ability of conducting a diagnostic evaluation as good or excellent. Most of the respondents used the e-learning programme due to general interest (90%. Predictors for using the e-learning programme were Males (OR = 1.4, 95% CI 1.1; 2.0 and members of Danish College of General Practice (OR = 2.2, 95% CI 1.5; 3.1, whereas age, experience and working place did not seem to be influential. Conclusion Only few Danish GPs used the e-learning programme in the first 6 months after the launching. Those using it were more often males and members of Danish College of General Practice. Based on this study we conclude, that an active implementation is needed, also when considering electronic formats of CME like e-learning. Trial Registration ClinicalTrials.gov Identifier: NCT00392483.

  1. A review of the fundamental principles of radiation protection when applied to the patient in diagnostic radiology

    International Nuclear Information System (INIS)

    Moores, B. Michael

    2017-01-01

    A review of the role and relevance of the principles of radiation protection of the patient in diagnostic radiology as specified by ICRP has been undertaken when diagnostic risks arising from an examination are taken into account. The increase in population doses arising from diagnostic radiology over the past 20 years has been due to the widespread application of higher dose CT examinations that provide significantly more clinical information. Consequently, diagnostic risks as well as radiation risks need to be considered within the patient radiation protection framework. Justification and optimisation are discussed and the limitations imposed on patient protection by employing only a radiation risk framework is highlighted. The example of radiation protection of the patient in breast screening programmes employing mammography is used to highlight the importance of defined diagnostic outcomes in any effective radiation protection strategy. (author)

  2. Design lessons from using programmable controllers in the MFTF-B personnel safety and interlocks system

    International Nuclear Information System (INIS)

    Branum, J.D.

    1983-01-01

    Applying programmable controllers in critical applications such as personnel safety and interlocks systems requires special considerations in the design of both hardware and software. All modern programmable controller systems feature extensive internal diagnostic capabilities to protect against problems such as program memory errors; however most, if not all present designs lack an intrinsic capability for detecting and countering failures on the field-side of their I/O modules. Many of the most common styles of I/O modules can also introduce potentially dangerous sneak circuits, even without component failure. This paper presents the most significant lessons learned to date in the design of the MFTF-B Personnel Safety and Interlocks System, which utilizes two non-redundant programmable controllers with over 800 I/O points each. Specific problems recognized during the design process as well as those discovered during initial testing and operation are discussed along with their specific solutions in hardware and software

  3. Feedback control of acoustic musical instruments: collocated control using physical analogs.

    Science.gov (United States)

    Berdahl, Edgar; Smith, Julius O; Niemeyer, Günter

    2012-01-01

    Traditionally, the average professional musician has owned numerous acoustic musical instruments, many of them having distinctive acoustic qualities. However, a modern musician could prefer to have a single musical instrument whose acoustics are programmable by feedback control, where acoustic variables are estimated from sensor measurements in real time and then fed back in order to influence the controlled variables. In this paper, theory is presented that describes stable feedback control of an acoustic musical instrument. The presentation should be accessible to members of the musical acoustics community who may have limited or no experience with feedback control. First, the only control strategy guaranteed to be stable subject to any musical instrument mobility is described: the sensors and actuators must be collocated, and the controller must emulate a physical analog system. Next, the most fundamental feedback controllers and the corresponding physical analog systems are presented. The effects that these controllers have on acoustic musical instruments are described. Finally, practical design challenges are discussed. A proof explains why changing the resonance frequency of a musical resonance requires much more control power than changing the decay time of the resonance. © 2012 Acoustical Society of America.

  4. The EuroDIVERSITY Programme: Challenges of Biodiversity Science in Europe

    Science.gov (United States)

    Jonckheere, I.

    2009-04-01

    In close cooperation with its Member Organisations, the European Science Foundation (ESF) has launched since late 2003 a series of European Collaborative Research (EUROCORES) Programmes. Their aim is to enable researchers in different European countries to develop cooperation and scientific synergy in areas where European scale and scope are required in a global context. The EUROCORES instrument represents the first large scale attempt of national research (funding) agencies to act together against fragmentation, asynchronicity and duplication of research (funding) within Europe. Although covering all scientific fields, there are presently 13 EUROCORES Programmes dealing with cutting edge science in the fields of Earth, Climate and Environmental Sciences. The aim of the EuroDIVERSITY Programme is to support the emergence of an integrated biodiversity science based on an understanding of fundamental ecological and social processes that drive biodiversity changes and their impacts on ecosystem functioning and society. Ecological systems across the globe are being threatened or transformed at unprecedented rates from local to global scales due to the ever-increasing human domination of natural ecosystems. In particular, massive biodiversity changes are currently taking place, and this trend is expected to continue over the coming decades, driven by the increasing extension and globalisation of human affairs. The EuroDIVERSITY Programme meets the research need triggered by the increasing human footprint worldwide with a focus on generalisations across particular systems and on the generation and validation of theory relevant to experimental and empirical data. The EURODIVERSITY Programme tries to bridge the gaps between the natural and social sciences, between research work on terrestrial, freshwater and marine ecosystems, and between research work on plants, animals and micro-organisms. The Programme was launched in April 2006 and includes 10 international

  5. Instrumentation, Field Network And Process Automation for the LHC Cryogenic Line Tests

    CERN Document Server

    Bager, T; Bertrand, G; Casas-Cubillos, J; Gomes, P; Parente, C; Riddone, G; Suraci, A

    2000-01-01

    This paper describes the cryogenic control system and associated instrumentation of the test facility for 3 pre-series units of the LHC Cryogenic Distribution Line. For each unit, the process automation is based on a Programmable Logic Con-troller implementing more than 30 closed control loops and handling alarms, in-terlocks and overall process management. More than 160 sensors and actuators are distributed over 150 m on a Profibus DP/PA network. Parameterization, cali-bration and diagnosis are remotely available through the bus. Considering the diversity, amount and geographical distribution of the instru-mentation involved, this is a representative approach to the cryogenic control system for CERN's next accelerator.

  6. A campaign to study atmospheric pollution at the regional scale: the Escompte programme; Une experience d'etude de la pollution atmospherique a l'echelle regionale. Le programme Escompte

    Energy Technology Data Exchange (ETDEWEB)

    Durand, P. [Meteo-France - Centre National de Recherches Meteorologiques, Centre National de la Recherche Scientifique (CNRS URA 1357), 31 - Toulouse (France); Cros, B. [Observatoire Midi-Pyrenees, Lab. d' Aerologie, Centre National de la Recherche Scientifique (CNRS UMR 5560), 31 - Toulouse (France)

    2004-02-01

    The Escompte programme was set up to improve and validate regional scale chemistry-transport numerical models. During summer 2001, an ambitious field campaign collected data on the meteorological and chemical parameters of the atmosphere during some photo-oxidant pollution events. Performed in the region of Marseille city and Berre lake, this campaign deployed a huge quantity of instruments, and constitutes one of the major operations in this field. (authors)

  7. Application of tissue mesodissection to molecular cancer diagnostics.

    Science.gov (United States)

    Krizman, David; Adey, Nils; Parry, Robert

    2015-02-01

    To demonstrate clinical application of a mesodissection platform that was developed to combine advantages of laser-based instrumentation with the speed/ease of manual dissection for automated dissection of tissue off standard glass slides. Genomic analysis for KRAS gene mutation was performed on formalin fixed paraffin embedded (FFPE) cancer patient tissue that was dissected using the mesodissection platform. Selected reaction monitoring proteomic analysis for quantitative Her2 protein expression was performed on FFPE patient tumour tissue dissected by a laser-based instrument and the MilliSect instrument. Genomic analysis demonstrates highly confident detection of KRAS mutation specifically in lung cancer cells and not the surrounding benign, non-tumour tissue. Proteomic analysis demonstrates Her2 quantitative protein expression in breast cancer cells dissected manually, by laser-based instrumentation and by MilliSect instrumentation (mesodissection). Slide-mounted tissue dissection is commonly performed using laser-based instruments or manually scraping tissue by scalpel. Here we demonstrate that the mesodissection platform as performed by the MilliSect instrument for tissue dissection is cost-effective; it functions comparably to laser-based dissection and which can be adopted into a clinical diagnostic workflow. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.

  8. Clinical Training of Medical Physicists Specializing in Diagnostic Radiology (French Edition)

    International Nuclear Information System (INIS)

    2012-01-01

    The application of radiation in human health, for both diagnosis and treatment of disease, is an important component of the work of the IAEA. The responsibility for the increasing technical aspects of this work is undertaken by the medical physicist. To ensure good practice in this vital area, structured clinical training programmes are required to complement academic learning. This publication is intended to be a guide to the practical implementation of such a programme for diagnostic radiology. There is a general and growing awareness that radiation medicine is increasingly dependent on well trained medical physicists based in the clinical setting. However, an analysis of the availability of medical physicists indicates a large shortfall of qualified and capable professionals. This is particularly evident in developing countries. While strategies to increase academic educational opportunities are critical to such countries, the need for guidance on structured clinical training was recognized by the members of the Regional Cooperative Agreement (RCA) for Research, Development and Training related to Nuclear Sciences for Asia and the Pacific. Consequently, a technical cooperation regional project (RAS6038) under the RCA programme was formulated to address this need in the Asia-Pacific region by developing suitable material and establishing its viability. Development of a clinical training guide for medical physicists specializing in diagnostic radiology started in 2007 with the appointment of a core drafting committee of regional and international experts. The publication drew on the experiences of clinical training programmes in Australia and New Zealand, the UK and the USA, and was moderated by physicists working in the Asian region. This publication follows the approach of the IAEA publication Training Course Series No. 37, Clinical Training of Medical Physicists specializing in Radiation Oncology. This approach to clinical training has been successfully tested

  9. Clinical Training of Medical Physicists Specializing in Diagnostic Radiology (Spanish Edition)

    International Nuclear Information System (INIS)

    2013-01-01

    The application of radiation in human health, for both diagnosis and treatment of disease, is an important component of the work of the IAEA. The responsibility for the increasing technical aspects of this work is undertaken by the medical physicist. To ensure good practice in this vital area, structured clinical training programmes are required to complement academic learning. This publication is intended to be a guide to the practical implementation of such a programme for diagnostic radiology. There is a general and growing awareness that radiation medicine is increasingly dependent on well trained medical physicists based in the clinical setting. However, an analysis of the availability of medical physicists indicates a large shortfall of qualified and capable professionals. This is particularly evident in developing countries. While strategies to increase academic educational opportunities are critical to such countries, the need for guidance on structured clinical training was recognized by the members of the Regional Cooperative Agreement (RCA) for Research, Development and Training related to Nuclear Sciences for Asia and the Pacific. Consequently, a technical cooperation regional project (RAS6038) under the RCA programme was formulated to address this need in the Asia-Pacific region by developing suitable material and establishing its viability. Development of a clinical training guide for medical physicists specializing in diagnostic radiology started in 2007 with the appointment of a core drafting committee of regional and international experts. The publication drew on the experiences of clinical training programmes in Australia and New Zealand, the UK and the USA, and was moderated by physicists working in the Asian region. This publication follows the approach of the IAEA publication Training Course Series No. 37, Clinical Training of Medical Physicists specializing in Radiation Oncology. This approach to clinical training has been successfully tested

  10. The pilot evaluation for the National Evaluation System in South Africa – A diagnostic review of early childhood development

    Directory of Open Access Journals (Sweden)

    Margot Davids

    2015-10-01

    Full Text Available Policymaking in many instances does not follow proper diagnosis of a problem using evidence to justify why particular decisions have been taken. This article describes findings of a diagnostic review of existing challenges facing early childhood development (ECD in South Africa. The review is part of the government’s attempt to use information to drive policy in strategic areas. It is part of the role that the Presidency is seeking to play in ensuring government programmes are evaluated to ensure that money that is spent is spent on programmes that have an impact and that there is value for money. This article summarises the key findings of the diagnostic review that was conducted of policy, services and coordination.The results reveal that a broader definition of ECD programmes is needed to cover all aspects of children’s development, growth and health, from conception to the foundation phase of schooling. Many elements of comprehensive ECD support and services are already in place and some are performing well. However, there are important gaps. Key ECD strategies for the future are identified. The diagnostic evaluation used a variety of methods, including desktop analysis, interviews and data analysis. Issues emerged around how to link the evaluation with other processes in the involved departments. A particular challenge was how to handle the transition to implementation of the findings, as responsibility shifted from the steering committee to the departments. The process worked well despite past challenges with coordination across government.

  11. Modernization project of the rod control system and in-core instrumentation system for 34 units of the 900 MW French EDF fleet

    International Nuclear Information System (INIS)

    Tavolara, Ivan; Verburgh, Pierre; Menager, Antoine

    2010-01-01

    Rolls-Royce and Cegelec, in partnership, carry out a unique and considerable modernisation project of two Instrumentation and Control (I and C) systems for the entire 900 MWe fleet of Electricite De France (EDF). Both rod control (RCS) and reactor in-core measurement (RIC) systems are to be modernised in the frame of the third ten-year renovation of all 34 reactor units over 9 power plants. The RCS contributes to the control of nuclear power by actuating control rod drive mechanisms that allow insertion or withdrawal of control rods. The RCS has also monitoring functions such as controlling the actual rods' position as well as the functional consistency between commands and actual positions. The RIC system measures in-core neutron flux, providing useful information to the control room as well as to the reactor unit computer for further processing. The renovated systems shall replace the existing ageing analog technology by modern digital technology based on PLC (Programmable Logic Controllers) and FPGA (Field-Programmable Gate Array) in the case of power subassemblies of RCS. Both systems rely for certain functions on a common network linking the RCS and RIC networks, improving operations and maintenance thanks to a powerful Man Machine Interface at the different locations of the systems with an extensive suite of tools and diagnostic menus. The project whose design phase started in July 2006 is now in its deployment phase after the successful site implementation of both systems at the first units of Tricastin and Fessenheim power plants, respectively in August 2009 and February 2010. The deployment shall continue with the other 32 units until 2020. Rolls-Royce has a broad range of civil nuclear expertise, including work related to licensing and safety reviews, engineering design, supply chain management, manufacturing, installation and commissioning of the nuclear island systems and equipment, as well as operational management through life support. Cegelec, with

  12. Design aspects of safety critical instrumentation of nuclear installations

    Energy Technology Data Exchange (ETDEWEB)

    Swaminathan, P. [Electronics Group, Indira Gandhi Centre for Atomic Research, Kalpakkam 603 102, Tamil Nadu (India)]. E-mail: swamy@igcar.ernet.in

    2005-07-01

    Safety critical instrumentation systems ensure safe shutdown/configuration of the nuclear installation when process status exceeds the safety threshold limits. Design requirements for safety critical instrumentation such as functional and electrical independence, fail-safe design, and architecture to ensure the specified unsafe failure rate and safe failure rate, human machine interface (HMI), etc., are explained with examples. Different fault tolerant architectures like 1/2, 2/2, 2/3 hot stand-by are compared for safety critical instrumentation. For embedded systems, software quality assurance is detailed both during design phase and O and M phase. Different software development models such as waterfall model and spiral model are explained with examples. The error distribution in embedded system is detailed. The usage of formal method is outlined to reduce the specification error. The guidelines for coding of application software are outlined. The interface problems of safety critical instrumentation with sensors, actuators, other computer systems, etc., are detailed with examples. Testability and maintainability shall be taken into account during design phase. Online diagnostics for safety critical instrumentation is detailed with examples. Salient details of design guides from Atomic Energy Regulatory Board, International Atomic Energy Agency and standards from IEEE, BIS are given towards the design of safety critical instrumentation systems. (author)

  13. Design aspects of safety critical instrumentation of nuclear installations

    International Nuclear Information System (INIS)

    Swaminathan, P.

    2005-01-01

    Safety critical instrumentation systems ensure safe shutdown/configuration of the nuclear installation when process status exceeds the safety threshold limits. Design requirements for safety critical instrumentation such as functional and electrical independence, fail-safe design, and architecture to ensure the specified unsafe failure rate and safe failure rate, human machine interface (HMI), etc., are explained with examples. Different fault tolerant architectures like 1/2, 2/2, 2/3 hot stand-by are compared for safety critical instrumentation. For embedded systems, software quality assurance is detailed both during design phase and O and M phase. Different software development models such as waterfall model and spiral model are explained with examples. The error distribution in embedded system is detailed. The usage of formal method is outlined to reduce the specification error. The guidelines for coding of application software are outlined. The interface problems of safety critical instrumentation with sensors, actuators, other computer systems, etc., are detailed with examples. Testability and maintainability shall be taken into account during design phase. Online diagnostics for safety critical instrumentation is detailed with examples. Salient details of design guides from Atomic Energy Regulatory Board, International Atomic Energy Agency and standards from IEEE, BIS are given towards the design of safety critical instrumentation systems. (author)

  14. Voluntary agreements - a measure for energy-efficiency in industry? Lessons from a Swedish programme

    Energy Technology Data Exchange (ETDEWEB)

    Linden, Anna- Lisa [Department of Sociology, Lund University P.O. Box 114, SE-221 00, Lund, (Sweden); Carlsson-Kanyama, Annika [Environmental Strategies Research Group, P.O. Box 2142, SE-103 14, Stockholm, (Sweden)

    2002-08-01

    Voluntary agreements represent a policy instrument for applying new knowledge, routines or technology to specified issues. The traditional role of an authority when using information, and taking economic, or administrative measures is that of an initiator and controller. Voluntary agreements, on the other hand, represent a communication process between an authority and a partner where relations of dependency and mutuality are more important in advancing the programme. This article analyses and discusses the motivational aspects of voluntary agreements, the role of the contract, advising, information, education, time planning and the importance of reporting and evaluation in energy-efficiency programmes. Besides sociological and communication theories, the discussion is based on the outcome of an evaluation of a Swedish energy-efficiency programme. Among the conclusions are that communication processes have to be planned and implemented in time sequences and steps of measures, which was partially neglected in the Swedish programme. Also, agreements between partners have to be defined in ways valid for all partners. In the Swedish programme, quantitative goals, at least measured in kWh, were impossible to achieve for some industries. On the other hand, most industries reported progress in side effects of energy efficiency as for example transportation policy for products, recirculation of waste material, lighting policy and behaviour, qualifications for ISO labelling. Information in combination with voluntary agreements can be efficient for industrial energy conservation. The education and auditing that was part of the Swedish programme were highly appreciated and added to the achievements. (Author)

  15. Psychological ownership: Development of an instrument

    Directory of Open Access Journals (Sweden)

    Chantal Olckers

    2013-10-01

    Purpose: The purpose of this study was to develop an instrument to measure psychological ownership in a South African context. Motivation for the study: It was found that previous instruments for the measurement of psychological ownership lacked the ability to grasp the extensive reach of psychological ownership. Research design, approach and method: A quantitative cross-sectional survey was conducted on a non-probability convenience sample of 713 skilled, highly-skilled and professional employees from various organisations in both the private and public sectors in South Africa. Main findings: Although a 69-item measurement instrument was developed in order to capture the proposed seven-dimensional psychological ownership construct, it became evident when analysing the data that a four-factor model comprising 35 items was suitable. Practical/managerial implications: If a sense of psychological ownership toward an organisation could be established amongst its employees by addressing the factors as measured by the South African Psychological Ownership Questionnaire, organisations could become enhanced workplaces and, as a result, sustainable performance could be promoted and staff could be retained. Contribution/value-add: The instrument for measuring psychological ownership in a South African context could serve as a diagnostic tool that would allow human resource professionals and managers to determine employees’ sense of psychological ownership regarding their organisation and to focus specifically on weak dimensional areas that could be improved.

  16. The multiple faces of a sustainability strategy. Analysing Finland's programme to promote sustainable consumption and production

    Energy Technology Data Exchange (ETDEWEB)

    Berg, A.

    2012-07-01

    effects; (3) has had a strong ritual function in renewing Finnish participatory policy-making traditions and faith in the corporatist capabilities of meeting difficult challenges; and (4) reveals how key discursive conflicts in the field are related to contradictions between efficiency and sufficiency, economic growth and its opposing forces, and regulation versus the so-called new environmental policy instruments. Given their institutional ambiguity, sustainability programmes should be conducted in a more transparent and clearly externalised manner than is necessary in traditional Bullet-style programmes. The setting allows for creativity, flexibility and tailoring. However, neither the ambiguity of the programmes nor the availability of new policy instruments justify the outsourcing of policy-making to actors who do not possess the power or the ability to act on the challenges. Further, in order to find a balanced approach towards SCP, additional institutional support should be given to processes and experiments that develop the sufficiency and degrowth ideas. In its current form, criticism of growth only increases the uncertainty and complexity. This, in turn, supports the position of the dominant growth-bound policy narratives. (orig.)

  17. Status of the Tandem Mirror Experiment-Upgrade (TMX-U) diagnostic system

    International Nuclear Information System (INIS)

    Coutts, G.W.; Coffield, F.E.; Hornady, R.S.

    1983-01-01

    This paper presents the current status of the Tandem Mirror Experiment-Upgrade (TMX-U) diagnostics system. For the initial instruments active on TMX-U, the expansions or upgrades that have been implemented are outlined. For the newly added systems, more implementation details are presented

  18. A new informant-based questionnaire for instrumental activities of daily living in dementia

    NARCIS (Netherlands)

    Sikkes, S.A.M.; de Lange-de Klerk, E.S.M.; Pijnenburg, Y.A.L.; Gillissen, F.; Romkes, R.; Knol, D.L.; Uitdehaag, B.M.J.; Scheltens, P.

    2012-01-01

    Background: Interference in everyday functioning is part of the diagnostic criteria for dementia. Questionnaires measuring "instrumental activities of daily living" (IADL) are used to measure this interference, but the psychometric quality of these questionnaires is often questioned. In addition,

  19. Mitigation of intergranular stress corrosion cracking in RBMK reactors. Final report of the programme's steering committee

    International Nuclear Information System (INIS)

    2002-09-01

    In 2000 the IAEA initiated an Extrabudgetary Programme on Mitigation of Intergranular Stress Corrosion Cracking in RBMK Reactors to assist countries operating RBMK reactors in addressing the issue in austenitic stainless steel 300 mm diameter piping. Intergranular stress corrosion cracking of austenitic stainless steel piping in BWRs has been a major safety concern since the early seventies. Similar degradation was found in RBMK reactor piping in 1997. Early in 1998 the IAEA responded to requests for assistance from RBMK operating countries on this issue through activities organized in the framework of Technical Co-operation Department regional projects and the Extrabudgetary Programme on the Safety of WWER and RBMK Nuclear Power Plants. Results of these activities were a basis for the formulation of the objective and scope of the Extrabudgetary Programme on Mitigation of Intergranular Stress Corrosion Cracking in RBMK reactors ('the Programme'). The scope of the Programme included in-service inspection, assessment, repair and mitigation, and water chemistry and decontamination. The Programme was pursued by means of exchange of experience, formulation of guidance, transfer of technology, and training, which will assist the RBMK operators to address related safety concerns. The Programme implementation relied on voluntary extrabudgetary financial contributions from Japan, Spain, the United Kingdom and the USA, and on in kind contributions from Finland, Germany and Sweden. The Programme was implemented in close co-ordination with ongoing national and bilateral activities and major inputs to the Programme were provided through the activities of the Swedish International Project Nuclear Safety and of the US DOE International Nuclear Safety Program. The RBMK nuclear power plants in Lithuania, Russian Federation and Ukraine hosted most of the Programme activities. Support of these Member States involved in the Programme was instrumental for its successful completion in

  20. Psychometric properties of assessment instruments for autism spectrum disorder: a systematic review of Brazilian studies

    Directory of Open Access Journals (Sweden)

    Bárbara Backes

    2014-07-01

    Full Text Available Objective To systematically review the scientific literature on the psychometric properties of international instruments for the assessment of autism spectrum disorder (ASD in the Brazilian population. Methods A search of bibliographic references was conducted in six electronic databases: PsycINFO, PubMed, IndexPsi, Lilacs, Capes (theses and dissertations and SciELO. The studies were selected by two independent researchers. Results The procedure identified 11 studies of the Brazilian population that encompassed six ASD assessment tools. Given the information provided, the adaptation of the M-CHAT, a screening instrument, was the best conducted. All steps of the adaptation process were described and the changes made to the final version of the instrument were presented, which was not addressed in other studies. In terms of reliability, all of the instruments that assessed internal consistency showed adequate values. In addition, the ADI-R and the CARS adaptations also satisfactorily contemplated inter-rater reliability and test-retest indices, respectively. Finally, all studies aiming to validate instruments showed evidence of validity and sensitivity, and specificity values above 0.90 were observed in the ASQ, ADI-R and ABC. Conclusion Considering both the psychometric aspects and the copyright information, the screening instrument that currently appears to be best indicated for clinical and research use is the M-CHAT. It was also noticed that there are still no specific ASD diagnostic tools available for use in Brazil. This lack of diagnostic instruments consists in a critical situation for the improvement of clinical practice and the development of research in this area.

  1. Recent Activities on the Experimental Research Programme Using Small Tokamaks

    International Nuclear Information System (INIS)

    Gryaznevich, M. P.; Bosco, E. del; Malaquias, A.; Mank, G.; Oost, G. van

    2006-01-01

    A new concept of interactive co-ordinated research using small tokamaks in the mainstream fusion science areas, in testing of new diagnostics, materials and technologies as well as in education, training and broadening of the geography of fusion research in the scope of the IAEA Co-ordinated Research Project (CRP) is discussed in this paper. Besides the presentation of the recent activities on the experimental research programme using small tokamaks and scientific results achieved at the participating laboratories, information is provided about the organisation of the co-ordinated research project. Future plans of the co-ordinated activities within the CRP are discussed

  2. Challenges for Plasma Diagnostic in a Next Step Device (FIRE)

    International Nuclear Information System (INIS)

    Young, Kenneth M.

    2002-01-01

    The physics program of any next-step tokamak such as FIRE [Fusion Ignition Research Experiment] sets demands for plasma measurement which are at least as comprehensive as on present tokamaks, with the additional capabilities needed for control of the plasma and for understanding the effects of the alpha-particles. The diagnostic instrumentation must be able to provide the fine spatial and temporal resolution required for the advanced tokamak plasma scenarios. It must also be able to overcome the effects of neutron- and gamma-induced electrical noise in ceramic components or detectors, and fluorescence and absorption in optical components. There are practical engineering issues of minimizing radiation streaming while providing essential diagnostic access to the plasma. Many diagnostics will require components at or close to the first wall, e.g., ceramics and MI cable for magnetic diagnostics and mirrors for optical diagnostics; these components must be mounted to operate, and survive, i n fluxes which require special material selection. A better set of diagnostics of alpha-particles than that available for the TFTR [Tokamak Fusion Test Reactor] is essential; it must be qualified well before moving into D-T [deuterim-tritium] experiments. A start has been made to assessing the potential implementation of key diagnostics for the FIRE device. The present status is described

  3. WHO-IAEA join forces to fight cancer. New Joint Programme cements partnership, promotes synergy

    International Nuclear Information System (INIS)

    2009-01-01

    On the 26th May 2009 the World Health Organization (WHO) and the International Atomic Energy Agency (IAEA) announced the launch of a Joint Programme on Cancer Control, aimed at strengthening and accelerating efforts to fight cancer in the developing world. WHO and the IAEA have complementary mandates when it comes to fighting cancer. WHO is the leader amongst the UN family of organizations in terms of health improvement for people, particularly in low- and middle-income countries, while the IAEA's expertise in radiation medicine is a vital element of cancer diagnosis and treatment. The Joint Programme will provide the framework for the two Organizations to dovetail their work, building on their areas of expertise to create a more coordinated and robust approach to combating cancer in poor countries. In practical terms, this will mean working with Member States to integrate diagnostic and treatment-related activities into cancer control plans of the country based on WHO cancer control guidelines and strategies in each region. Efforts in the joint programme are focusing on six PACT Model Demonstration Sites (PMDS) in Albania, Nicaragua, Sri Lanka, Tanzania, Viet Nam and Yemen. They will also respond to requests for cancer control assessment and programme development assistance in low- and middle-income countries

  4. An Initial Study of the Diagnostic Utility of the Emotional and Behavioural Screener in Lithuania

    Science.gov (United States)

    Sointu, Erkko; Lambert, Matthew C.; Nordness, Philip D.; Geležiniene, Renata; Epstein, Michael H.

    2018-01-01

    In schools, screening is an effective method to identify students at-risk for emotional and behavioural disorders. Several intervention programmes such as Positive Behaviour Interventions and Supports, Response to Intervention, and Multi-tiered Systems of Supports call for the use of psychometrically sound screening instruments. This study…

  5. Acoustic detection in superconducting magnets for performance characterization and diagnostics

    International Nuclear Information System (INIS)

    Marchevsky, M; Wang, X; Sabbi, G; Prestemon, S

    2013-01-01

    Quench diagnostics in superconducting accelerator magnets is essential for understanding performance limitations and improving magnet design. Applicability of the conventional quench diagnostics methods such as voltage taps or quench antennas is limited for long magnets or complex winding geometries, and alternative approaches are desirable. Here, we discuss acoustic sensing technique for detecting mechanical vibrations in superconducting magnets. Using LARP high-field Nb3Sn quadrupole HQ01, we show how acoustic data is connected with voltage instabilities measured simultaneously in the magnet windings during provoked extractions and current ramps to quench. Instrumentation and data analysis techniques for acoustic sensing are reviewed. (author)

  6. Acoustic detection in superconducting magnets for performance characterization and diagnostics

    CERN Document Server

    Marchevsky, M.; Sabbi, G.; Prestemon, S.

    2013-01-01

    Quench diagnostics in superconducting accelerator magnets is essential for understanding performance limitations and improving magnet design. Applicability of the conventional quench diagnostics methods such as voltage taps or quench antennas is limited for long magnets or complex winding geometries, and alternative approaches are desirable. Here, we discuss acoustic sensing technique for detecting mechanical vibrations in superconducting magnets. Using LARP high-field Nb$_{3}$Sn quadrupole HQ01 [1], we show how acoustic data is connected with voltage instabilities measured simultaneously in the magnet windings during provoked extractions and current ramps to quench. Instrumentation and data analysis techniques for acoustic sensing are reviewed.

  7. Regulatory issues on using programmable logic device in nuclear power plants

    International Nuclear Information System (INIS)

    Park, G. Y.; Yu, Y. J.; Kim, H. T.; Kwon, Y. I.; Park, H. S.; Jeong, C. H.

    2012-01-01

    For replacing obsolete analog equipment in nuclear power plant, the Programmable Logic Devices (PLDs) using Hardware Description Language (HDL) have been widely adopted in digitalized Instrumentation and Control (I and C) systems because of its flexibility. For safety reviews on Nuclear Power Plants (NPPs,) qualifying digitalized safety I and C system using PLDs is an important issue. As an effort to provide regulatory position on using PLDs in safety I and C system, there is a research project to provide the regulatory positions against emerging issues involved with digitalisation of I and C system including using PLDs. Therefore, this paper addresses the important considerations for using PLDs in safety I and C systems such as diversity, independence and qualification, etc. In this point, this study focuses on technical reports for Field Programmable Gate Array (FPGA) from EPRI,. U.S. NRC, and relevant technical standards

  8. Regulatory issues on using programmable logic device in nuclear power plants

    Energy Technology Data Exchange (ETDEWEB)

    Park, G. Y.; Yu, Y. J.; Kim, H. T.; Kwon, Y. I.; Park, H. S.; Jeong, C. H. [Korea Institute of Nuclear Safety, Daejeon (Korea, Republic of)

    2012-10-15

    For replacing obsolete analog equipment in nuclear power plant, the Programmable Logic Devices (PLDs) using Hardware Description Language (HDL) have been widely adopted in digitalized Instrumentation and Control (I and C) systems because of its flexibility. For safety reviews on Nuclear Power Plants (NPPs,) qualifying digitalized safety I and C system using PLDs is an important issue. As an effort to provide regulatory position on using PLDs in safety I and C system, there is a research project to provide the regulatory positions against emerging issues involved with digitalisation of I and C system including using PLDs. Therefore, this paper addresses the important considerations for using PLDs in safety I and C systems such as diversity, independence and qualification, etc. In this point, this study focuses on technical reports for Field Programmable Gate Array (FPGA) from EPRI,. U.S. NRC, and relevant technical standards.

  9. An overview of the International Electrotechnical Commission's activities on quality assurance in diagnostic radiology

    International Nuclear Information System (INIS)

    Julius, H.W.; Ammers, H. van; Henshaw, E.T.

    1989-01-01

    In 1981, the International Electrotechnical Commission Sub-committee 62B set up a Working Group (WG 10) to deal with quality assurance in diagnostic X-ray departments and, more specifically, to develop international standards describing procedures to test the constancy of parameters of diagnostic X-ray installations. Since then, the working group has produced a report on General Aspects of Quality Assurance in Diagnostic X-ray Departments and four draft standards on specific topics, while seven more documents are in advanced drafting stage. Several others are presently under consideration. According to the approach adopted by the Working Group, these documents are meant to assist in establishing quality assurance programmes in hospitals and provide guidance on how to perform the tests and interpret their results. This paper reveals the general philosophy behind the activities of the Working Group as well as some details of the standard produced so far, with emphasis on the physical parameters of diagnostic X-ray installations and their proposed criteria for satisfactory performance. (author)

  10. Auditing emergency management programmes: Measuring leading indicators of programme performance.

    Science.gov (United States)

    Tomsic, Heather

    Emergency Management Programmes benefit from review and measurement against established criteria. By measuring current vs required programme elements for their actual currency, completeness and effectiveness, the resulting timely reports of achievements and documentation of identified gaps can effectively be used to rationally support prioritised improvement. Audits, with their detailed, triangulated and objectively weighted processes, are the ultimate approach in terms of programme content measurement. Although Emergency Management is often presented as a wholly separate operational mechanism, distinct and functionally different from the organisation's usual management structure, this characterisation is only completely accurate while managing an emergency itself. Otherwise, an organisation's Emergency Management Programme is embedded within that organisation and dependent upon it. Therefore, the organisation's culture and structure of management, accountability and measurement must be engaged for the programme to exist, much less improve. A wise and successful Emergency Management Coordinator does not let the separate and distinct nature of managing an emergency obscure their realisation of the need for an organisation to understand and manage all of the other programme components as part of its regular business practices. This includes its measurement. Not all organisations are sufficiently large or capable of supporting the use of an audit. This paper proposes that alternate, less formal, yet effective mechanisms can be explored, as long as they reflect and support organisational management norms, including a process of relatively informal measurement focused on the organisation's own perception of key Emergency Management Programme performance indicators.

  11. Patient and Staff (doctors and nurses) Experiences of Abdominal Hysterectomy in Accelerated Recovery Programme

    DEFF Research Database (Denmark)

    Wagner, Lis; Carlslund, Anne Mette; Møller, Charlotte

    2004-01-01

    Introduction: The accelerated recovery programme (ARP) is becoming commonplace in surgical specialties and has also been introduced to hysterectomy patients. Diagnostic, prognostic and other clinical indicators are well described. The aim of this article is to relay knowledge about the ARP, through...... of information relay and dialogue between staff and patients/family members. A nursing care ambulatory unit is recommended to support with information for women prior to and following hysterectomy in the ARP....

  12. Passive Spectroscopic Diagnostics for Magnetically-confined Fusion Plasmas

    International Nuclear Information System (INIS)

    Stratton, B.C.; Bitter, M.; Hill, K.W.; Hillis, D.L.; Hogan, J.T.

    2007-01-01

    Spectroscopy of radiation emitted by impurities and hydrogen isotopes plays an important role in the study of magnetically-confined fusion plasmas, both in determining the effects of impurities on plasma behavior and in measurements of plasma parameters such as electron and ion temperatures and densities, particle transport, and particle influx rates. This paper reviews spectroscopic diagnostics of plasma radiation that are excited by collisional processes in the plasma, which are termed 'passive' spectroscopic diagnostics to distinguish them from 'active' spectroscopic diagnostics involving injected particle and laser beams. A brief overview of the ionization balance in hot plasmas and the relevant line and continuum radiation excitation mechanisms is given. Instrumentation in the soft X-ray, vacuum ultraviolet, ultraviolet, visible, and near-infrared regions of the spectrum is described and examples of measurements are given. Paths for further development of these measurements and issues for their implementation in a burning plasma environment are discussed.

  13. Passive Spectroscopic Diagnostics for Magnetically-confined Fusion Plasmas

    Energy Technology Data Exchange (ETDEWEB)

    Stratton, B. C.; Biter, M.; Hill, K. W.; Hillis, D. L.; Hogan, J. T.

    2007-07-18

    Spectroscopy of radiation emitted by impurities and hydrogen isotopes plays an important role in the study of magnetically-confined fusion plasmas, both in determining the effects of impurities on plasma behavior and in measurements of plasma parameters such as electron and ion temperatures and densities, particle transport, and particle influx rates. This paper reviews spectroscopic diagnostics of plasma radiation that are excited by collisional processes in the plasma, which are termed 'passive' spectroscopic diagnostics to distinguish them from 'active' spectroscopic diagnostics involving injected particle and laser beams. A brief overview of the ionization balance in hot plasmas and the relevant line and continuum radiation excitation mechanisms is given. Instrumentation in the soft X-ray, vacuum ultraviolet, ultraviolet, visible, and near-infrared regions of the spectrum is described and examples of measurements are given. Paths for further development of these measurements and issues for their implementation in a burning plasma environment are discussed.

  14. Knowledge transfer and innovation in cross-border cooperation programmes between Finland and Russia

    DEFF Research Database (Denmark)

    Makkonen, Teemu; Williams, Allan; Weidenfeld, Adi

    2017-01-01

    Cross-border cooperation (CBC) at the European Union’s (EU) external borders has been promoted via programmes, such as the European Neighbourhood and Partnership Instrument (ENPI), funded jointly by the EU and participating countries. However, little empirical attention has been laid to these pro...... the actors in opposing sides of the border, is actually the main factor that facilitates and creates potential for learning, knowledge transfer and innovation to take place in the Finnish-Russian cross-border region....... to these programmes in terms of their role in enhancing cross-border knowledge transfer and innovation, particularly in the field of tourism. To shed light on the issue, semi-structured interviews were conducted with representatives of (12 Russian; 12 Finnish) organisations that had participated in ENPI CBC funded...... tourism related Finnish-Russian cross-border projects. The results shed light on the possibilities of and obstacles to cross-border knowledge transfer and innovation. ENPI CBC programmes between Finland and Russia are highly relevant for successful cross-border knowledge transfer and innovation...

  15. [Muenster Parental Programme--Feedback from Parents: How do parents evaluate an early intervention programme for improving the communication with their baby or toddler with hearing impairment?].

    Science.gov (United States)

    Glanemann, R; Reichmuth, K; am Zehnhoff-Dinnesen, A

    2016-02-01

    With the implementation of the UNHS, early educational services' existing concepts of early intervention have to be adapted to the situation and needs of families with a preverbal child who is deaf or hard of hearing. The Muenster Parental Programme (MPP), a module in early family-centered intervention, fulfils this requirement. We report feedback from participating parents regarding processes and outcomes of the MPP. The self-developed questionnaire was checked for its suitability as feedback instrument for measuring parental satisfaction with the MPP. 29 parents who participated in the MPP assessed the programme by using the standardised FBB and the self-developed questionnaire FB-MEP, which is specific to the MPP. Using the FBB, 96% of parents judged the MPP to be good or very good. With the FB-MEP, parents rated setting, contents and didactics as highly as they did using the FBB (r = 0.7, p parents judged both the contact and exchange with other affected parents, and the specific individual support for communicating with their child (including video feedback) as especially helpful. The results reflect parents' high level of satisfaction with the setting, content, didactics and individual benefit gained by their child and themselves from the MPP. The parents are aware of the efficacy of the MPP, which was shown in the controlled intervention study. The self-developed questionnaire FB-MEP was shown to be a suitable instrument for quality assurance measurements of the MPP.

  16. Scanning control and data acquisition interface for a spectroscopy diagnostic

    International Nuclear Information System (INIS)

    Lopez-Callejas, R.; Galindo, S.; Benitez-Read, J.S.; Pacheco-Sotelo, J.; Longoria-Gandara, L.C.; Valencia-Alvarado, R.

    2001-01-01

    This work presents the design of a PC supported interface unit that improves the operation of a mechanically driven Czerny-Turner monochromator to the point of meeting the conditions required to be useful in wavelength separation and spectrum analysis for breakdown and conditioning discharges in plasma physics diagnostics. The PC supported interface verifies and sets the position and scan range of the instrument scanning drive. The interface consists of a microcontroller and its associated circuitry. The microcontroller is also used as a data acquisition and data manipulation element. An example of obtained spectra illustrating the instrument greatly improved performance is presented

  17. Development of a Cherenkov-type diagnostic system to study runaway electrons within the COMPASS tokamak

    Czech Academy of Sciences Publication Activity Database

    Rabinski, M.; Jakubowski, L.; Malinowski, K.; Sadowski, M. J.; Zebrowski, J.; Jakubowski, M.J.; Mirowski, R.; Weinzettl, Vladimír; Ficker, Ondřej; Mlynář, Jan; Pánek, Radomír; Papřok, Richard; Vlainic, Milos

    2017-01-01

    Roč. 12, October (2017), č. článku C10014. ISSN 1748-0221. [European Conference on Plasma Diagnostics (ECPD2017)/2./. Bordeaux, 18.04.2017-21.04.2017] R&D Projects: GA MŠk(CZ) LM2015045 Institutional support: RVO:61389021 Keywords : Nuclear instruments and methods for hot plasma diagnostics * Plasma diagnostics - probes Subject RIV: BL - Plasma and Gas Discharge Physics OBOR OECD: 2.11 Other engineering and technologies Impact factor: 1.220, year: 2016 http://iopscience.iop.org/article/10.1088/1748-0221/12/10/C10014

  18. Diagnostic Criteria for Temporomandibular Disorders (DC/TMD) for Clinical and Research Applications: Recommendations of the International RDC/TMD Consortium Network* and Orofacial Pain Special Interest Group†

    Science.gov (United States)

    Schiffman, Eric; Ohrbach, Richard; Truelove, Edmond; Look, John; Anderson, Gary; Goulet, Jean-Paul; List, Thomas; Svensson, Peter; Gonzalez, Yoly; Lobbezoo, Frank; Michelotti, Ambra; Brooks, Sharon L.; Ceusters, Werner; Drangsholt, Mark; Ettlin, Dominik; Gaul, Charly; Goldberg, Louis J.; Haythornthwaite, Jennifer A.; Hollender, Lars; Jensen, Rigmor; John, Mike T.; De Laat, Antoon; de Leeuw, Reny; Maixner, William; van der Meulen, Marylee; Murray, Greg M.; Nixdorf, Donald R.; Palla, Sandro; Petersson, Arne; Pionchon, Paul; Smith, Barry; Visscher, Corine M.; Zakrzewska, Joanna; Dworkin, Samuel F.

    2015-01-01

    Aims The original Research Diagnostic Criteria for Temporomandibular Disorders (RDC/TMD) Axis I diagnostic algorithms have been demonstrated to be reliable. However, the Validation Project determined that the RDC/TMD Axis I validity was below the target sensitivity of ≥ 0.70 and specificity of ≥ 0.95. Consequently, these empirical results supported the development of revised RDC/TMD Axis I diagnostic algorithms that were subsequently demonstrated to be valid for the most common pain-related TMD and for one temporomandibular joint (TMJ) intra-articular disorder. The original RDC/TMD Axis II instruments were shown to be both reliable and valid. Working from these findings and revisions, two international consensus workshops were convened, from which recommendations were obtained for the finalization of new Axis I diagnostic algorithms and new Axis II instruments. Methods Through a series of workshops and symposia, a panel of clinical and basic science pain experts modified the revised RDC/TMD Axis I algorithms by using comprehensive searches of published TMD diagnostic literature followed by review and consensus via a formal structured process. The panel's recommendations for further revision of the Axis I diagnostic algorithms were assessed for validity by using the Validation Project's data set, and for reliability by using newly collected data from the ongoing TMJ Impact Project—the follow-up study to the Validation Project. New Axis II instruments were identified through a comprehensive search of the literature providing valid instruments that, relative to the RDC/TMD, are shorter in length, are available in the public domain, and currently are being used in medical settings. Results The newly recommended Diagnostic Criteria for TMD (DC/TMD) Axis I protocol includes both a valid screener for detecting any pain-related TMD as well as valid diagnostic criteria for differentiating the most common pain-related TMD (sensitivity ≥ 0.86, specificity ≥ 0

  19. Diagnostics of Shiva Nova produced high yield thermonuclear events

    International Nuclear Information System (INIS)

    Ahlstrom, H.G.; Banner, D.L.; Boyle, M.J.; Campbell, E.M.; Coleman, L.W.; Koppel, L.N.; Kornblum, H.N. Jr.; Rienecker, F.; Severyn, J.R.; Slivinsky, V.W.

    1978-01-01

    Experiments with the Shiva Nova laser facility which produce yield levels of scientific breakeven and above will result in neutron, x-ray and particle fluxes which will require specific attention to the survivability of diagnostic instrumentation. These yield levels will also allow the utilization of new diagnotics techniques which can provide detailed information on the state of the imploded fuel and pusher shells

  20. Instrumentation and Controls Division progress report, September 1, 1980-July 1, 1982

    Energy Technology Data Exchange (ETDEWEB)

    Klobe, L.E.E. (ed.)

    1982-12-01

    Activities are reported by the Reactor Systems Section, Research Instrument Section, and the Measurement and Controls Engineering Section. Reactor system activities include dynamic analysis, survillanc and diagnostic methods, design and evaluation, detectors, facilities support, process instrumentation development, and special assignments. Activities in the Research Instrument Section include the Navy-ORNL RADIAC development program, advanced ..gamma.. and x ray detector systems, neutron detection and subcriticality measurements, circuit development, position-sensitive detectors, stand-alone computers, environmental monitoring-detectors and systems, plant security, engineering support for fusion energy division, engineering support for accelerator physics, and communications: radio, closed-circuit tv, and computer. Activities in the Measurement and Controls Engineering Section include the AVLIS program; gas centrifuge enrichment technology support; Advanced Instrumentation for Reflood Studies (AIDRS) program; instrumentation development support for fuel reprocessing; in-core experiments and reactor systems; energy, conservation, and electric power systems; computer systems; measurements research; and fossil energy studies Publications are listed. (WHK)

  1. Instrumentation and Controls Division progress report, September 1, 1980-July 1, 1982

    International Nuclear Information System (INIS)

    Klobe, L.E.E.

    1982-12-01

    Activities are reported by the Reactor Systems Section, Research Instrument Section, and the Measurement and Controls Engineering Section. Reactor system activities include dynamic analysis, survillanc and diagnostic methods, design and evaluation, detectors, facilities support, process instrumentation development, and special assignments. Activities in the Research Instrument Section include the Navy-ORNL RADIAC development program, advanced #betta# and x ray detector systems, neutron detection and subcriticality measurements, circuit development, position-sensitive detectors, stand-alone computers, environmental monitoring-detectors and systems, plant security, engineering support for fusion energy division, engineering support for accelerator physics, and communications: radio, closed-circuit tv, and computer. Activities in the Measurement and Controls Engineering Section include the AVLIS program; gas centrifuge enrichment technology support; Advanced Instrumentation for Reflood Studies (AIDRS) program; instrumentation development support for fuel reprocessing; in-core experiments and reactor systems; energy, conservation, and electric power systems; computer systems; measurements research; and fossil energy studies Publications are listed

  2. Report of the second research co-ordination meeting on the co-ordinated research programme: rapid instrumental and separation methods for monitoring radionuclides in food and environmental samples

    International Nuclear Information System (INIS)

    1992-10-01

    The purpose of this Second Research Co-ordinated Meeting (12-16 August 1991) on Rapid Instrumental and Separation Methods for Monitoring Radionuclides in Food and Environmental Samples is to discuss the progress of the programmes since the First Research Co-ordination Meeting, discuss how to validate the methodologies developed (e.g. reference samples, intercomparisons), and outline a schedule for CRP completion by the end of 1992. Radioactive contamination of the environment after a nuclear accident, such as had occurred at Chernobyl, is of serious concern to government officials and members of the general public. In 1990/1991 the Agency was asked to organize the International Chernobyl Project to assess the situation in the USSR. A network of laboratories was organized to carry out the environmental assessment needed for this project. The following recommendations are based on the experience gained by many of the laboratories involved in this project. 1. Maintain a network of analytical laboratories with special skills and experience to provide assessments of radionuclide contamination in the environment in case of a radiological emergency. 2. Methodologies for assessment of contamination in the environment should take into consideration potential trajectories, radioecology, and food chain parameters. 3. Focus on areas of representative sample collection, is situ instrumental and chemical analysis, as well as advanced streamlined laboratory analyses which will facilitate the timeline of an assessment. 4. Conduct intercomparison and testing of technologies, employing standard reference materials and procedures, and field measurements at significantly contaminated area. 5. Conduct training of Member State laboratory personnel through fellowships, special courses, and workshops. 5 refs

  3. X-ray diagnostics for laser matter interaction experiments; Diagnostics X pour les experiences d'interaction laser-matiere

    Energy Technology Data Exchange (ETDEWEB)

    Troussel, Ph

    2000-07-01

    Advances in the field of laser-driven inertially confined thermonuclear fusion research since the early 1990's are reviewed. It covers the experimental techniques used to study the interaction of laser radiation with matter and high density plasma. A high performance instrumentation (diagnostics) for observation of X radiation (from a few eV to a few keV) will be required to understand the physical processes involved in the interaction. This paper is a three-part: first part, describes diagnostics metrology realized around different X-ray sources (synchrotron, laser plasma...); a second part, synthesizes theoretical and experimental X-ray optics studies and show the interest for direct applications as X-ray spectroscopy and X-ray imaging around laser-produced plasma; a third part, is a review of high resolution X-ray imaging, performances of these optical system were summarized. (author)

  4. Matter in Extreme Conditions Instrument - Conceptual Design Report

    Energy Technology Data Exchange (ETDEWEB)

    Boyce, R.F.; Boyce, R.M.; Haller, G.; Hastings, J.B.; Hays, G.; Lee, H.J.; /SLAC; Lee, R.W.; /LLNL, Livermore; Nagler, B.; /Rutherford; Scharfenstein, M.; Marsh, D.; White, W.E.; /SLAC

    2009-12-09

    to design, build, and install at the LCLS an X-ray instrument that will complement the initial instrument suite included in the LCLS construction and the LUSI Major Item of Equipment (MIE) Instruments. As the science programs advance and new technological challenges appear, instrumentation must be developed and ready to conquer these new opportunities. The MEC concept has been developed in close consultation with the scientific community through a series of workshops team meetings and focused reviews. In particular, the MEC instrument has been identified as meeting one of the most urgent needs of the scientific community based on the advice of the LCLS Scientific Advisory Committee (SAC) in response to an open call for letters of intent (LOI) from the breadth of the scientific community. The primary purpose of the MEC instrument is to create High Energy Density (HED) matter and measure its physical properties. There are three primary elements of the MEC instrument: (A) Optical laser drivers that will create HED states by irradiation in several ways and provide diagnostics capability; (B) The LCLS x-ray free electron laser, which will provide the unique capability to create, probe and selectively pump HED states; and, (C) A suite of diagnostic devices required to observe the evolution of the HED state. These elements when combined in the MEC instrument meet the 'Mission Need' as defined in CD-0. For the purposes of the description we separate the types of experiments to be performed into three categories: (1) High pressure: Here we are interested in the generation of high pressure using the optical lasers to irradiate a surface that ablates and drives a pressure wave into a sample, similar to a piston. The pressures that can be reached exceed 1 Mbar and the properties of interest are for example, the reflectivity, conductivity, opacity as well as the changes driven by the pressure wave on, e.g., condensed matter structure. These phenomena will be studied by

  5. Analyzer for gamma cameras diagnostic

    International Nuclear Information System (INIS)

    Oramas Polo, I.; Osorio Deliz, J. F.; Diaz Garcia, A.

    2013-01-01

    This research work was carried out to develop an analyzer for gamma cameras diagnostic. It is composed of an electronic system that includes hardware and software capabilities, and operates from the acquisition of the 4 head position signals of a gamma camera detector. The result is the spectrum of the energy delivered by nuclear radiation coming from the camera detector head. This system includes analog processing of position signals from the camera, digitization and the subsequent processing of the energy signal in a multichannel analyzer, sending data to a computer via a standard USB port and processing of data in a personal computer to obtain the final histogram. The circuits are composed of an analog processing board and a universal kit with micro controller and programmable gate array. (Author)

  6. Rational use of diagnostic radiology

    International Nuclear Information System (INIS)

    Racoveanu, N.T.; Volodin, V.

    1992-01-01

    Radiologists in USA and UK have since early 1970 questioned the efficacy of various radiological investigations and produced substantial evidence that more rational approaches are necessary. WHO initiated, in 1977, a programme which has issued four technical reports giving practical recommendations on how to rationalise the use of radiological examinations. Three main directions are considered: (1) Abandonment of routine radiological examinations, as procedures with no clinical or epidemiologic significance and which represent a waste of resources and patient dose. (2) Patient selection for various radiological investigations based on clinical criteria (high, intermediate, low yield). Selected patients have an increased prevalence of the given disease and the predictive value of radiological investigation is much higher. (3) Use of diagnostic algorithms with higher cost/efficiency and risk/benefit ratios, improving the outcome of radiological examinations. (author)

  7. GMES Space Component: Programme overview

    Science.gov (United States)

    Aschbacher, J.; Milagro-Perez, M. P.

    2012-04-01

    The European Union (EU) and the European Space Agency (ESA) have developed the Global Monitoring for Environment and Security (GMES) programme as Europe's answer to the vital need for joined-up data about our climate, environment and security. Through a unique combination of satellite, atmospheric and Earth-based monitoring systems, the initiative will provide new insight into the state of the land, sea and air, providing policymakers, scientists, businesses and the public with accurate and timely information. GMES capabilities include monitoring and forecasting of climatic change, flood risks, soil and coastal erosion, crop and fish resources, air pollution, greenhouse gases, iceberg distribution and snow cover, among others. To accomplish this, GMES has been divided into three main components: Space, In-situ and Services. The Space Component, led by ESA, comprises five types of new satellites called Sentinels that are being developed by ESA specifically to meet the needs of GMES, the first of which to be launched in 2013. These missions carry a range of technologies, such as radar and multi-spectral imaging instruments for land, ocean and atmospheric monitoring. In addition, access to data from the so-called Contributing Missions guarantees that European space infrastructure is fully used for GMES. An integrated Ground Segment ensures access to Sentinels and Contributing Missions data. The in-situ component, under the coordination of the European Environment Agency (EEA), is composed of atmospheric and Earth based monitoring systems, and based on established networks and programmes at European and international levels. The European Commission is in charge of implementing the services component of GMES and of leading GMES overall. GMES services, fed with data from the Space and In-situ components, will provide essential information in five main domains, atmosphere, ocean and land monitoring as well as emergency response and security. Climate change has been added

  8. Liulin-type spectrometry-dosimetry instruments

    International Nuclear Information System (INIS)

    Dachev, T.; Dimitrov, P.; Tomov, B.; Matviichuk, Y.; Spurny, F.; Ploc, O.; Brabcova, K.; Jadrnickova, I.

    2011-01-01

    The main purpose of Liulin-type spectrometry-dosimetry instruments (LSDIs) is cosmic radiation monitoring at the workplaces. An LSDI functionally is a low mass, low power consumption or battery-operated dosemeter. LSDIs were calibrated in a wide range of radiation fields, including radiation sources, proton and heavy-ion accelerators and CERN-EC high-energy reference field. Since 2000, LSDIs have been used in the scientific programmes of four manned space flights on the American Laboratory and ESA Columbus modules and on the Russian segment of the International Space Station, one Moon spacecraft and three spacecraft around the Earth, one rocket, two balloons and many aircraft flights. In addition to relative low price, LSDIs have proved their ability to qualify the radiation field on the ground and on the above-mentioned carriers. (authors)

  9. Health Technology Assessment for Molecular Diagnostics: Practices, Challenges, and Recommendations from the Medical Devices and Diagnostics Special Interest Group.

    Science.gov (United States)

    Garfield, Susan; Polisena, Julie; S Spinner, Daryl; Postulka, Anne; Y Lu, Christine; Tiwana, Simrandeep K; Faulkner, Eric; Poulios, Nick; Zah, Vladimir; Longacre, Michael

    2016-01-01

    Health technology assessments (HTAs) are increasingly used to inform coverage, access, and utilization of medical technologies including molecular diagnostics (MDx). Although MDx are used to screen patients and inform disease management and treatment decisions, there is no uniform approach to their evaluation by HTA organizations. The International Society for Pharmacoeconomics and Outcomes Research Devices and Diagnostics Special Interest Group reviewed diagnostic-specific HTA programs and identified elements representing common and best practices. MDx-specific HTA programs in Europe, Australia, and North America were characterized by methodology, evaluation framework, and impact. Published MDx HTAs were reviewed, and five representative case studies of test evaluations were developed: United Kingdom (National Institute for Health and Care Excellence's Diagnostics Assessment Programme, epidermal growth factor receptor tyrosine kinase mutation), United States (Palmetto's Molecular Diagnostic Services Program, OncotypeDx prostate cancer test), Germany (Institute for Quality and Efficiency in Healthcare, human papillomavirus testing), Australia (Medical Services Advisory Committee, anaplastic lymphoma kinase testing for non-small cell lung cancer), and Canada (Canadian Agency for Drugs and Technologies in Health, Rapid Response: Non-invasive Prenatal Testing). Overall, the few HTA programs that have MDx-specific methods do not provide clear parameters of acceptability related to clinical and analytic performance, clinical utility, and economic impact. The case studies highlight similarities and differences in evaluation approaches across HTAs in the performance metrics used (analytic and clinical validity, clinical utility), evidence requirements, and how value is measured. Not all HTAs are directly linked to reimbursement outcomes. To improve MDx HTAs, organizations should provide greater transparency, better communication and collaboration between industry and HTA

  10. Task 9. PV deployment in developing countries. Institutional framework and financial instruments for PV deployment in developing countries

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2003-09-15

    This report for the International Energy Agency (IEA) made by Task 9 of the Photovoltaic Power Systems (PVPS) programme takes a look at the institutional framework and financial instruments necessary for PV deployment in developing countries. This guide describes the institutional and financial aspects that need to be addressed to ensure that a long term sustainable (and profitable) PV market is established in developing countries. The guide details main fundamental functions that need to be performed such as the agents needed to perform the functions and their differing roles within the framework, the relationships between these agents and the financial instruments available. It is stated that the majority of the aspects recommended in this guide can be adopted to two main PV deployment models: direct sales and rural electrification and development programmes. It is noted that both approaches will have to be tailored and adapted to local conditions.

  11. Including refugees in disease elimination: challenges observed from a sleeping sickness programme in Uganda.

    Science.gov (United States)

    Palmer, Jennifer J; Robert, Okello; Kansiime, Freddie

    2017-01-01

    Ensuring equity between forcibly-displaced and host area populations is a key challenge for global elimination programmes. We studied Uganda's response to the recent refugee influx from South Sudan to identify key governance and operational lessons for national sleeping sickness programmes working with displaced populations today. A refugee policy which favours integration of primary healthcare services for refugee and host populations and the availability of rapid diagnostic tests (RDTs) to detect sleeping sickness at this health system level makes Uganda well-placed to include refugees in sleeping sickness surveillance. Using ethnographic observations of coordination meetings, review of programme data, interviews with sleeping sickness and refugee authorities and group discussions with health staff and refugees (2013-2016), we nevertheless identified some key challenges to equitably integrating refugees into government sleeping sickness surveillance. Despite fears that refugees were at risk of disease and posed a threat to elimination, six months into the response, programme coordinators progressed to a sentinel surveillance strategy in districts hosting the highest concentrations of refugees. This meant that RDTs, the programme's primary surveillance tool, were removed from most refugee-serving facilities, exacerbating existing inequitable access to surveillance and leading refugees to claim that their access to sleeping sickness tests had been better in South Sudan. This was not intentionally done to exclude refugees from care, rather, four key governance challenges made it difficult for the programme to recognise and correct inequities affecting refugees: (a) perceived donor pressure to reduce the sleeping sickness programme's scope without clear international elimination guidance on surveillance quality; (b) a problematic history of programme relations with refugee-hosting districts which strained supervision of surveillance quality; (c) difficulties that

  12. Nuclear Diagnostics at the National Ignition Facility, 2013-2015

    Science.gov (United States)

    Yeamans, C. B.; Cassata, W. S.; Church, J. A.; Fittinghoff, D. N.; Gatu Johnson, M.; Gharibyan, N.; Határik, R.; Sayre, D. B.; Sio, H. W.; Bionta, R. M.; Bleuel, D. L.; Caggiano, J. A.; Cerjan, C. J.; Cooper, G. W.; Eckart, M. J.; Edwards, E. R.; Faye, S. A.; Forrest, C. J.; Frenje, J. A.; Glebov, V. Yu; Grant, P. M.; Grim, G. P.; Hartouni, E. P.; Herrmann, H. W.; Kilkenny, J. D.; Knauer, J. P.; Mackinnon, A. J.; Merrill, F. E.; Moody, K. J.; Moran, M. J.; Petrasso, R. D.; Phillips, T. W.; Rinderknecht, H. G.; Schneider, D. H. G.; Sepke, S. M.; Shaughnessy, D. A.; Stoeffl, W.; Velsko, C. A.; Volegov, P.

    2016-05-01

    The National Ignition Facility (NIF) relies on a suite of nuclear diagnostics to measure the neutronic output of experiments. Neutron time-of-flight (NTOF) and neutron activation diagnostics (NAD) provide performance metrics of absolute neutron yield and neutron spectral content: spectral width and non-thermal content, from which implosion physical quantities of temperature and scattering mass are inferred. Spatially-distributed flange- mounted NADs (FNAD) measure, with nearly identical systematic uncertainties, primary DT neutron emission to infer a whole-sky neutron field. An automated FNAD system is being developed. A magnetic recoil spectrometer (MRS) shares few systematics with comparable NTOF and NAD devices, and as such is deployed for independent measurement of the primary neutronic quantities. The gas-Cherenkov Gamma Reaction History (GRH) instrument records four energy channels of time-resolved gamma emission to measure nuclear bang time and burn width, as well as to infer carbon areal density in experiments utilizing plastic or diamond capsules. A neutron imaging system (NIS) takes two images of the neutron source, typically gated to create coregistered 13-15 MeV primary and 6-12 MeV downscattered images. The radiochemical analysis of gaseous samples (RAGS) instrument pumps target chamber gas to a chemical reaction and fractionation system configured with gamma counters, allowing measurement of radionuclides with half-lives as short as 8 seconds. Solid radiochemistry collectors (SRC) with backing NAD foils collect target debris, where activated materials from the target assembly are used as indicators of neutron spectrum content, and also serve as the primary diagnostic for nuclear forensic science experiments. Particle time-of-flight (PTOF) measures compression-bang time using DT- or DD-neutrons, as well as shock bang-time using D3He-protons for implosions with lower x-ray background. In concert, these diagnostics serve to measure the basic and advanced

  13. An overview of the International Electrotechnical Commission's activities on quality assurance in diagnostic radiology

    International Nuclear Information System (INIS)

    Julius, H.W.; Ammers, H. van; Henshaw, E.T.

    1989-01-01

    In 1981, the International Electrotechnical Commission Sub-committee 62B set up a Working Group to deal with quality assurance in diagnostic X-ray departments and, more specifically, to develop international standards describing procedures to test the constancy of parameters of diagnostic X-ray Departments, four draft standards on specific topics, seven more documents are in advanced stage, and several others under consideration. According to the approach adopted by the Working Group, these documents are meant to assist in establishing quality assurance programmes in hospitals and provide guidance on how to perform tests and interpret results. This paper reveals the general philosophy behind the activities of the Working Group as well as some details of the standards produced so far, with emphasis on physical parameters of diagnostic X-ray installations and proposed criteria for satisfactory performance. (author)

  14. LHC Beam Diagnostics - the Users Point of View

    CERN Document Server

    Wenninger, J

    2011-01-01

    The LHC started up with beam in November 2009, and within less then on year its luminosity reached 2·1032 cm-2s−1 at 3.5 TeV in October 2010. A few weeks later, in November 2010, lead ion collisions were established within little over 2 days. The fast progress and successes of the LHC commissioning and early operation would not have been possible without the excellent performance of its beam instrumentation. All essential instruments worked from the first day or were commissioned in a very short time, providing rapid diagnostics for the beam parameters. Tune and orbit feedbacks that rely on high quality measurements were used early on to achieve smooth operation with minimal beam losses. This presentation will address the performance of the LHC beam instrumentation, in particular the very large beam position and beam loss monitoring systems, both composed of many thousand channels. Present limitations and future improvements will also be discussed.

  15. A qualitative review of instrumental activities of daily living in dementia: what's cooking?

    NARCIS (Netherlands)

    Sikkes, S.A.M.; de Rotrou, J.

    2014-01-01

    The measurement of instrumental activities of daily living (IADL) is common in clinical practice and research into dementia. IADL are cognitively complex daily activities, such as cooking and doing finances. Their measurement is required for the diagnostic process of dementia, and also useful for

  16. The relative age effect in the German Football TID Programme: biases in motor performance diagnostics and effects on single motor abilities and skills in groups of selected players.

    Science.gov (United States)

    Votteler, Andreas; Höner, Oliver

    2014-01-01

    This study examined the disturbing effects of relative age on the talent identification process in the talent development programme of the German Football Association. The bias in the selection rate was examined via the extent of relative age effects. The bias in motor performance diagnostics was analysed by comparing the motor performance of selected players with normal motor development. The mechanisms underlying the relative age biases in motor performance were examined by modelling the direct and indirect effects of relative age on single motor performance tests for sprint, running agility, dribbling and ball passing and control. Data from 10,130 selected football players from the U12 to U15 age groups were collected in autumn 2010. The birth distribution differed significantly from the reference population with approximately 61% of the players born in the first half of the year. The selection probability was approximately two times higher for players born in the first quarter of the year than for players born in the last quarter. Revised motor performance diagnostics showed better results on average for relatively younger players. Path analysis revealed significant direct and indirect relative age effects for physiologically demanding tests and almost no effects for technically demanding tests. Large sample sizes allowed high resolution in relative age with additional informational content and multivariate modelling of the complex relationships among relative age, physical development and motor performance. The results are discussed on how relative age affects the effectiveness and fairness of talent identification and development processes.

  17. Multifunctional Nanomaterials Utilizing Hybridization Chain Reaction for Molecular Diagnostics and Bioanalytical Applications

    Science.gov (United States)

    Rana, Md. Muhit

    DNA nanotechnology has shown great promise in molecular diagnostic, bioanalytical and biomedical applications. The great challenge of detecting target analytes, biomarkers and small molecules, in molecular diagnostics is low yield sensitivity. To address this challenge, different nanomaterials have been used for a long time and to date there is no such cost-effective bioanalytical technique which can detect these target biomarkers (DNA, RNA, circulating DNA/miRNA) or environmental heavy metal ions (Hg2+ and Ag+) in a cost-effective and efficient manner. Herein, we initially discuss two possible bioanalytical detection methods- a) colorimetric and b) fluorometric assays which are very popular nowadays due to their distinctive spectroscopic properties. Finally, we report the promising colorimetric assay using a novel DNA based amplification strategy know as hybridization chain reaction (HCR) for potential application in the visual detection of low copies of biomarkers (miRNAs as little as 20 femtomole in an RNA pool and cell extracts in seven different combinations and Ebola virus DNA as low as 400 attomoles in liquid biopsy mimics in sixteen different combinations), environmental and biological heavy metal ions (mercury and silver concentrations as low as 10 pM in water, soil and urine samples) and also successfully applied to a molecular logic gate operation to distinguish OR and AND logic gates. No results showed any false-positive or false-negative information. On the other hand, we also discuss the future possibilities of HCR amplification technology, which is very promising for fluorometric bioanalysis. The HCR based nanoprobe technology has numerous remarkable advantages over other methods. It is re-programmable, simple, inexpensive, easy to assemble and operate and can be performed with visual and spectroscopic read-outs upon recognition of the target analytes. This rapid, specific and sensitive approach for biomarkers and heavy metal ion detection generates

  18. A REVIEW OF THE FUNDAMENTAL PRINCIPLES OF RADIATION PROTECTION WHEN APPLIED TO THE PATIENT IN DIAGNOSTIC RADIOLOGY.

    Science.gov (United States)

    Moores, B Michael

    2017-06-01

    A review of the role and relevance of the principles of radiation protection of the patient in diagnostic radiology as specified by ICRP has been undertaken when diagnostic risks arising from an examination are taken into account. The increase in population doses arising from diagnostic radiology over the past 20 years has been due to the widespread application of higher dose CT examinations that provide significantly more clinical information. Consequently, diagnostic risks as well as radiation risks need to be considered within the patient radiation protection framework. Justification and optimisation are discussed and the limitations imposed on patient protection by employing only a radiation risk framework is highlighted. The example of radiation protection of the patient in breast screening programmes employing mammography is used to highlight the importance of defined diagnostic outcomes in any effective radiation protection strategy. © The Author 2016. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  19. DIAGNOSTICS OF VIRUS PHYTOPATHOGENS FRUIT TREE PLUM POX VIRUS, PRUNUS NECROTIC RINGSPOT VIRUS AND PRUNUS DWARF VIRUS BY BIOLOGICAL AND MOLECULAR DIAGNOSTICS

    Directory of Open Access Journals (Sweden)

    Július Rozák

    2013-02-01

    Full Text Available The aim of this study was to determine the incidence of viral phytopathogen Plum pox virus, Prunus necrotic ringspot virus and Prunus dwarf virus in selected localities of Slovakia and diagnose them using a molecular and biological methods. Forty samples of fruit trees of the genus Prunus, twenty samples from intensive plantings and twenty samples from wild subject were analysed. Biological diagnostic by using biological indicators Prunus persica cv. GF 305, Prunus serrulata cv. Schirofugen and molecular diagnostic by mRT-PCR were applied. Five samples with Plum pox virus were infected. The two samples positive for Prunus necrotic ringspot virus and one sample for Prunus dwarf virus were confirmed. The two samples were found to be infected with two viruses Prunus necrotic ringspot virus and Prunus dwarf virus. This work focuses on two techniques, their application to the diagnosis of stone fruit viruses and their routinely used for sanitary and certification programmes.

  20. Specialized beam diagnostic measurements for an ADTT accelerator funnel

    Energy Technology Data Exchange (ETDEWEB)

    Gilpatrick, J.D.

    1995-10-01

    Los Alamos National Laboratory has proposed several CW-proton-beam facilities for accelerator-driven transmutation technologies (ADTT) with beam-current densities greater than 5 mA/mm{sup 2}. The primary beam-diagnostics-instrumentation requirement for these facilities is to provide sufficient beam information to understand and minimize beam-loss. To accomplish this task, the beam diagnostics instrumentation must measure beam parameters such as the projected centroids and profiles, total integrated current, and particle loss. Because of the high specific energy loss in materials at beam energies less than 20 MeV, interceptive measurements such as wire scanners or fluors cannot be used to determine beam profiles or centroids. Therefore, noninterceptive techniques must be used for on-line diagnosis of high-intensity CW beam at low energies. The beam funnel area of these proposed accelerator facilities provide a particular interesting beam measurement challenge. In this area of the accelerator, beam measurements must also sense how well the two funnel-input-beams are matched to each other in phase space. This paper will discuss some of the measurement requirements for these proposed accelerator facilities and the various noninterceptive techniques to measure dual-beam funnel operation.