WorldWideScience

Sample records for programmable array microscope

  1. Biological applications of an LCoS-BASED PROGRAMMABLE ARRAY MICROSCOPE (PAM)

    NARCIS (Netherlands)

    Hagen, G.M.; Caarls, W.; Thomas, M.; Hill, A.; Lidke, K.A.; Rieger, B.; Fritsch, C.; Van Geest, B.; Jovin, T.M.; Arndt-Jovin, D.J.

    2007-01-01

    We report on a new generation, commercial prototype of a programmable array optical sectioning fluorescence microscope (PAM) for rapid, light efficient 3D imaging of living specimens. The stand-alone module, including light source(s) and detector(s), features an innovative optical design and a

  2. Generation-3 programmable array microscope (PAM) with digital micro-mirror device (DMD)

    Science.gov (United States)

    De Beule, Pieter A. A.; de Vries, Anthony H. B.; Arndt-Jovin, Donna J.; Jovin, Thomas M.

    2011-03-01

    We report progress on the construction of an optical sectioning programmable array microscope (PAM) implemented with a digital micro-mirror device (DMD) spatial light modulator (SLM) utilized for both fluorescence illumination and detection. The introduction of binary intensity modulation at the focal plane of a microscope objective in a computer controlled pixilated mode allows the recovery of an optically sectioned image. Illumination patterns can be changed very quickly, in contrast to static Nipkow disk or aperture correlation implementations, thereby creating an optical system that can be optimized to the optical specimen in a convenient manner, e.g. for patterned photobleaching, photobleaching reduction, or spatial superresolution. We present a third generation (Gen-3) dual path PAM module incorporating the 25 kHz binary frame rate TI 1080p DMD and a newly developed optical system that offers diffraction limited imaging with compensation of tilt angle distortion.

  3. Field programmable gate array based reconfigurable scanning probe/optical microscope.

    Science.gov (United States)

    Nowak, Derek B; Lawrence, A J; Dzegede, Zechariah K; Hiester, Justin C; Kim, Cliff; Sánchez, Erik J

    2011-10-01

    The increasing popularity of nanometrology and nanospectroscopy has pushed researchers to develop complex new analytical systems. This paper describes the development of a platform on which to build a microscopy tool that will allow for flexibility of customization to suit research needs. The novelty of the described system lies in its versatility of capabilities. So far, one version of this microscope has allowed for successful near-field and far-field fluorescence imaging with single molecule detection sensitivity. This system is easily adapted for reflection, polarization (Kerr magneto-optical (MO)), Raman, super-resolution techniques, and other novel scanning probe imaging and spectroscopic designs. While collecting a variety of forms of optical images, the system can simultaneously monitor topographic information of a sample with an integrated tuning fork based shear force system. The instrument has the ability to image at room temperature and atmospheric pressure or under liquid. The core of the design is a field programmable gate array (FPGA) data acquisition card and a single, low cost computer to control the microscope with analog control circuitry using off-the-shelf available components. A detailed description of electronics, mechanical requirements, and software algorithms as well as examples of some different forms of the microscope developed so far are discussed.

  4. A versatile LabVIEW and field-programmable gate array-based scanning probe microscope for in operando electronic device characterization.

    Science.gov (United States)

    Berger, Andrew J; Page, Michael R; Jacob, Jan; Young, Justin R; Lewis, Jim; Wenzel, Lothar; Bhallamudi, Vidya P; Johnston-Halperin, Ezekiel; Pelekhov, Denis V; Hammel, P Chris

    2014-12-01

    Understanding the complex properties of electronic and spintronic devices at the micro- and nano-scale is a topic of intense current interest as it becomes increasingly important for scientific progress and technological applications. In operando characterization of such devices by scanning probe techniques is particularly well-suited for the microscopic study of these properties. We have developed a scanning probe microscope (SPM) which is capable of both standard force imaging (atomic, magnetic, electrostatic) and simultaneous electrical transport measurements. We utilize flexible and inexpensive FPGA (field-programmable gate array) hardware and a custom software framework developed in National Instrument's LabVIEW environment to perform the various aspects of microscope operation and device measurement. The FPGA-based approach enables sensitive, real-time cantilever frequency-shift detection. Using this system, we demonstrate electrostatic force microscopy of an electrically biased graphene field-effect transistor device. The combination of SPM and electrical transport also enables imaging of the transport response to a localized perturbation provided by the scanned cantilever tip. Facilitated by the broad presence of LabVIEW in the experimental sciences and the openness of our software solution, our system permits a wide variety of combined scanning and transport measurements by providing standardized interfaces and flexible access to all aspects of a measurement (input and output signals, and processed data). Our system also enables precise control of timing (synchronization of scanning and transport operations) and implementation of sophisticated feedback protocols, and thus should be broadly interesting and useful to practitioners in the field.

  5. A versatile LabVIEW and field-programmable gate array-based scanning probe microscope for in operando electronic device characterization

    Energy Technology Data Exchange (ETDEWEB)

    Berger, Andrew J., E-mail: berger.156@osu.edu; Page, Michael R.; Young, Justin R.; Bhallamudi, Vidya P.; Johnston-Halperin, Ezekiel; Pelekhov, Denis V.; Hammel, P. Chris [Department of Physics, The Ohio State University, Columbus, Ohio 43210 (United States); Jacob, Jan [Werum Software and Systems CIS AG, Wulf-Werum-Straße 3, 21337 Lüneburg (Germany); Lewis, Jim; Wenzel, Lothar [National Instruments, Austin, Texas 78759 (United States)

    2014-12-15

    Understanding the complex properties of electronic and spintronic devices at the micro- and nano-scale is a topic of intense current interest as it becomes increasingly important for scientific progress and technological applications. In operando characterization of such devices by scanning probe techniques is particularly well-suited for the microscopic study of these properties. We have developed a scanning probe microscope (SPM) which is capable of both standard force imaging (atomic, magnetic, electrostatic) and simultaneous electrical transport measurements. We utilize flexible and inexpensive FPGA (field-programmable gate array) hardware and a custom software framework developed in National Instrument's LabVIEW environment to perform the various aspects of microscope operation and device measurement. The FPGA-based approach enables sensitive, real-time cantilever frequency-shift detection. Using this system, we demonstrate electrostatic force microscopy of an electrically biased graphene field-effect transistor device. The combination of SPM and electrical transport also enables imaging of the transport response to a localized perturbation provided by the scanned cantilever tip. Facilitated by the broad presence of LabVIEW in the experimental sciences and the openness of our software solution, our system permits a wide variety of combined scanning and transport measurements by providing standardized interfaces and flexible access to all aspects of a measurement (input and output signals, and processed data). Our system also enables precise control of timing (synchronization of scanning and transport operations) and implementation of sophisticated feedback protocols, and thus should be broadly interesting and useful to practitioners in the field.

  6. A versatile LabVIEW and field-programmable gate array-based scanning probe microscope for in operando electronic device characterization

    Science.gov (United States)

    Berger, Andrew J.; Page, Michael R.; Jacob, Jan; Young, Justin R.; Lewis, Jim; Wenzel, Lothar; Bhallamudi, Vidya P.; Johnston-Halperin, Ezekiel; Pelekhov, Denis V.; Hammel, P. Chris

    2014-12-01

    Understanding the complex properties of electronic and spintronic devices at the micro- and nano-scale is a topic of intense current interest as it becomes increasingly important for scientific progress and technological applications. In operando characterization of such devices by scanning probe techniques is particularly well-suited for the microscopic study of these properties. We have developed a scanning probe microscope (SPM) which is capable of both standard force imaging (atomic, magnetic, electrostatic) and simultaneous electrical transport measurements. We utilize flexible and inexpensive FPGA (field-programmable gate array) hardware and a custom software framework developed in National Instrument's LabVIEW environment to perform the various aspects of microscope operation and device measurement. The FPGA-based approach enables sensitive, real-time cantilever frequency-shift detection. Using this system, we demonstrate electrostatic force microscopy of an electrically biased graphene field-effect transistor device. The combination of SPM and electrical transport also enables imaging of the transport response to a localized perturbation provided by the scanned cantilever tip. Facilitated by the broad presence of LabVIEW in the experimental sciences and the openness of our software solution, our system permits a wide variety of combined scanning and transport measurements by providing standardized interfaces and flexible access to all aspects of a measurement (input and output signals, and processed data). Our system also enables precise control of timing (synchronization of scanning and transport operations) and implementation of sophisticated feedback protocols, and thus should be broadly interesting and useful to practitioners in the field.

  7. Image Filtering with Field Programmable Gate Array

    Directory of Open Access Journals (Sweden)

    Arūnas Šlenderis

    2013-05-01

    Full Text Available The research examined the use of field programmable gate arrays (FPGA in image filtering. Experimental and theoretical researches were reviewed. Experiments with Cyclone III family FPGA chip with implemented NIOS II soft processor were considered. Image filtering was achieved with symmetrical and asymmetrical finite impulse response filters with convolution kernel. The system, which was implemented with 3×3 symmetrical filter, which was implemented using the hardware description language, uses 59% of logic elements of the chip and 10 multiplication elements. The system with asymmetrical filter uses the same amount of logic elements and 13 multiplication elements. Both filter systems consume approx. 545 mW of power. The system, which is designed for filter implementation in C language, uses 65% of all logical elements and consumes 729 mW of power.Article in Lithuanian

  8. Dielectrophoretic spectroscopy using a microscopic electrode array

    Science.gov (United States)

    Kirmani, Syed Abdul Mannan; Gudagunti, Fleming Dackson; Velmanickam, Logeeshan; Nawarathna, Dharmakeerthi; Lima, Ivan T.

    2017-02-01

    Dielectrophoresis (DEP) is a commonly used technique in biomedical engineering to manipulate biomolecules. DEP is defined as the force acting on dielectric particles when they are exposed to non-uniform electric fields. DEP effect can be divided in three categories: positive (dielectric particles are attracted to the electrodes), negative, and zero force DEP. The cross-over frequency is the frequency in which the DEP force is equal to zero. The cross-over frequency depends on the conductivity and the permittivity of the particles and of the suspended medium. The DEP cross-over frequency has been utilized in detecting/quantifying biomolecules. A manual procedure is commonly used to estimate the cross-over frequency of biomolecules. Therefore, the accuracy of this detection method is significantly limited. To address this issue, we designed and tested an automated procedure to carry out DEP spectroscopy in dielectric particles dissolved in a biological buffer solution. Our method efficiently measures the effect of the DEP force through a live video feed from the microscope camera and performs real-time image processing. It records the change in the fluorescence emission as the system automatically scans the electric frequency of the function generator over a specified time interval. We demonstrated the effectiveness of the method by extracting the crossover frequencies and the DEP spectrum of polystyrene beads with blue color dye (1000 nm diameter) and green fluorescent polystyrene beads with 500 nm diameter using this procedure. This approach can lead to the development of a biosensor with significantly higher sensitivity than existing detection methods.

  9. Programmable Periodicity of Quantum Dot Arrays with DNA Origami Nanotubes

    OpenAIRE

    Bui, Hieu; Onodera, Craig; Kidwell, Carson; Tan, Yerpeng; Graugnard, Elton; Kuang, Wan; Lee, Jeunghoon; Knowlton, William B.; Yurke, Bernard; Hughes, William L.

    2010-01-01

    To fabricate quantum dot arrays with programmable periodicity, functionalized DNA origami nanotubes were developed. Selected DNA staple strands were biotin-labeled to form periodic binding sites for streptavidin-conjugated quantum dots. Successful formation of arrays with periods of 43 and 71 nm demonstrates precise, programmable, large-scale nanoparticle patterning; however, limitations in array periodicity were also observed. Statistical analysis of AFM images revealed evidence for steric h...

  10. Arrays of microscopic organic LEDs for high-resolution optogenetics.

    Science.gov (United States)

    Steude, Anja; Witts, Emily C; Miles, Gareth B; Gather, Malte C

    2016-05-01

    Optogenetics is a paradigm-changing new method to study and manipulate the behavior of cells with light. Following major advances of the used genetic constructs over the last decade, the light sources required for optogenetic control are now receiving increased attention. We report a novel optogenetic illumination platform based on high-density arrays of microscopic organic light-emitting diodes (OLEDs). Because of the small dimensions of each array element (6 × 9 μm(2)) and the use of ultrathin device encapsulation, these arrays enable illumination of cells with unprecedented spatiotemporal resolution. We show that adherent eukaryotic cells readily proliferate on these arrays, and we demonstrate specific light-induced control of the ionic current across the membrane of individual live cells expressing different optogenetic constructs. Our work paves the way for the use of OLEDs for cell-specific optogenetic control in cultured neuronal networks and for acute brain slices, or as implants in vivo.

  11. Experimental 3D Asynchronous Field Programmable Gate Array (FPGA)

    Science.gov (United States)

    2015-03-01

    EXPERIMENTAL 3D ASYNCHRONOUS FIELD PROGRAMMABLE GATE ARRAY ( FPGA ) CORNELL UNIVERSITY MARCH 2015 FINAL TECHNICAL REPORT APPROVED FOR PUBLIC...From - To) OCT 2011 – OCT 2014 4. TITLE AND SUBTITLE EXPERIMENTAL 3D ASYNCHRONOUS FIELD PROGRAMMABLE GATE ARRAY ( FPGA ) 5a. CONTRACT NUMBER...in collaboration with Albany’s College of Nanoscale Science and Engineering. 15. SUBJECT TERMS 3D Technology, vertical interconnects, AFPGA, FPGA

  12. Design of a Ferroelectric Programmable Logic Gate Array

    Science.gov (United States)

    MacLeod, Todd C.; Ho, Fat Duen

    2003-01-01

    A programmable logic gate array has been designed utilizing ferroelectric field effect transistors. The design has only a small number of gates, but this could be scaled up to a more useful size. Using FFET's in a logic array gives several advantages. First, it allows real-time programmability to the array to give high speed reconfiguration. It also allows the array to be configured nearly an unlimited number of times, unlike a FLASH FPGA. Finally, the Ferroelectric Programmable Logic Gate Array (FPLGA) can be implemented using a smaller number of transistors because of the inherent logic characteristics of an FFET. The device was only designed and modeled using Spice models of the circuit, including the FFET. The actual device was not produced. The design consists of a small array of NAND and NOR logic gates. Other gates could easily be produced. They are linked by FFET's that control the logic flow. Timing and logic tables have been produced showing the array can produce a variety of logic combinations at a real time usable speed. This device could be a prototype for a device that could be put into imbedded systems that need the high speed of hardware implementation of logic and the complexity to need to change the logic algorithm. Because of the non-volatile nature of the FFET, it would also be useful in situations that needed to program a logic array once and use it repeatedly after the power has been shut off.

  13. Programmable Aperture with MEMS Microshutter Arrays

    Science.gov (United States)

    Moseley, Samuel; Li, Mary; Kutyrev, Alexander; Kletetschka, Gunther; Fettig, Rainer

    2011-01-01

    A microshutter array (MSA) has been developed for use as an aperture array for multi-object selections in James Webb Space Telescope (JWST) technology. Light shields, molybdenum nitride (MoN) coating on shutters, and aluminum/aluminum oxide coatings on interior walls are put on each shutter for light leak prevention, and to enhance optical contrast. Individual shutters are patterned with a torsion flexure that permits shutters to open 90 deg. with a minimized mechanical stress concentration. The shutters are actuated magnetically, latched, and addressed electrostatically. Also, micromechanical features are tailored onto individual shutters to prevent stiction. An individual shutter consists of a torsion hinge, a shutter blade, a front electrode that is coated on the shutter blade, a backside electrode that is coated on the interior walls, and a magnetic cobalt-iron coating. The magnetic coating is patterned into stripes on microshutters so that shutters can respond to an external magnetic field for the magnetic actuation. A set of column electrodes is placed on top of shutters, and a set of row electrodes on sidewalls is underneath the shutters so that they can be electrostatically latched open. A linear permanent magnet is aligned with the shutter rows and is positioned above a flipped upside-down array, and sweeps across the array in a direction parallel to shutter columns. As the magnet sweeps across the array, sequential rows of shutters are rotated from their natural horizontal orientation to a vertical open position, where they approach vertical electrodes on the sidewalls. When the electrodes are biased with a sufficient electrostatic force to overcome the mechanical restoring force of torsion bars, shutters remain latched to vertical electrodes in their open state. When the bias is removed, or is insufficient, the shutters return to their horizontal, closed positions. To release a shutter, both the electrode on the shutter and the one on the back wall where

  14. Flat-top illumination profile in an epifluorescence microscope by dual microlens arrays

    NARCIS (Netherlands)

    Coumans, F.A.W.; van der Pol, E.; Terstappen, Leonardus Wendelinus Mathias Marie

    2012-01-01

    Low uniformity in illumination across the image plane impairs the ability of a traditional epifluorescence microscope to quantify fluorescence intensities. Two microlens arrays (MLAs) were introduced into the illumination path of two different epifluorescence microscope systems to improve the

  15. Optical Doppler tomography based on a field programmable gate array

    DEFF Research Database (Denmark)

    Larsen, Henning Engelbrecht; Nilsson, Ronnie Thorup; Thrane, Lars

    2008-01-01

    We report the design of and results obtained by using a field programmable gate array (FPGA) to digitally process optical Doppler tomography signals. The processor fits into the analog signal path in an existing optical coherence tomography setup. We demonstrate both Doppler frequency and envelope...

  16. Introduction to embedded system design using field programmable gate arrays

    CERN Document Server

    Dubey, Rahul

    2009-01-01

    Offers information on the use of field programmable gate arrays (FPGAs) in the design of embedded systems. This text considers a hypothetical robot controller as an embedded application and weaves around it related concepts of FPGA-based digital design. It is suitable for both students and designers who have worked with microprocessors.

  17. Mapping of DSP Algorithms on Field Programmable Function Arrays

    NARCIS (Netherlands)

    Heysters, P.M.; Smit, Jaap; Smit, Gerardus Johannes Maria; Havinga, Paul J.M.

    This position paper discusses reconfigurability issues in low-power hand-held multimedia systems. A reconfigurable systems-architecture is introduced, with a focus on a Field Programmable Function Array (FPFA). Application domain specific algorithms determine the granularity of FPFA processor tiles.

  18. Multi-Contrast Imaging and Digital Refocusing on a Mobile Microscope with a Domed LED Array.

    Directory of Open Access Journals (Sweden)

    Zachary F Phillips

    Full Text Available We demonstrate the design and application of an add-on device for improving the diagnostic and research capabilities of CellScope--a low-cost, smartphone-based point-of-care microscope. We replace the single LED illumination of the original CellScope with a programmable domed LED array. By leveraging recent advances in computational illumination, this new device enables simultaneous multi-contrast imaging with brightfield, darkfield, and phase imaging modes. Further, we scan through illumination angles to capture lightfield datasets, which can be used to recover 3D intensity and phase images without any hardware changes. This digital refocusing procedure can be used for either 3D imaging or software-only focus correction, reducing the need for precise mechanical focusing during field experiments. All acquisition and processing is performed on the mobile phone and controlled through a smartphone application, making the computational microscope compact and portable. Using multiple samples and different objective magnifications, we demonstrate that the performance of our device is comparable to that of a commercial microscope. This unique device platform extends the field imaging capabilities of CellScope, opening up new clinical and research possibilities.

  19. Multi-Contrast Imaging and Digital Refocusing on a Mobile Microscope with a Domed LED Array.

    Science.gov (United States)

    Phillips, Zachary F; D'Ambrosio, Michael V; Tian, Lei; Rulison, Jared J; Patel, Hurshal S; Sadras, Nitin; Gande, Aditya V; Switz, Neil A; Fletcher, Daniel A; Waller, Laura

    2015-01-01

    We demonstrate the design and application of an add-on device for improving the diagnostic and research capabilities of CellScope--a low-cost, smartphone-based point-of-care microscope. We replace the single LED illumination of the original CellScope with a programmable domed LED array. By leveraging recent advances in computational illumination, this new device enables simultaneous multi-contrast imaging with brightfield, darkfield, and phase imaging modes. Further, we scan through illumination angles to capture lightfield datasets, which can be used to recover 3D intensity and phase images without any hardware changes. This digital refocusing procedure can be used for either 3D imaging or software-only focus correction, reducing the need for precise mechanical focusing during field experiments. All acquisition and processing is performed on the mobile phone and controlled through a smartphone application, making the computational microscope compact and portable. Using multiple samples and different objective magnifications, we demonstrate that the performance of our device is comparable to that of a commercial microscope. This unique device platform extends the field imaging capabilities of CellScope, opening up new clinical and research possibilities.

  20. Evaluation of a miniature microscope objective designed for fluorescence array microscopy detection of Mycobacterium tuberculosis.

    Science.gov (United States)

    McCall, Brian; Olsen, Randall J; Nelles, Nicole J; Williams, Dawn L; Jackson, Kevin; Richards-Kortum, Rebecca; Graviss, Edward A; Tkaczyk, Tomasz S

    2014-03-01

    A prototype miniature objective that was designed for a point-of-care diagnostic array microscope for detection of Mycobacterium tuberculosis and previously fabricated and presented in a proof of concept is evaluated for its effectiveness in detecting acid-fast bacteria. To evaluate the ability of the microscope to resolve submicron features and details in the image of acid-fast microorganisms stained with a fluorescent dye, and to evaluate the accuracy of clinical diagnoses made with digital images acquired with the objective. The lens prescription data for the microscope design are presented. A test platform is built by combining parts of a standard microscope, a prototype objective, and a digital single-lens reflex camera. Counts of acid-fast bacteria made with the prototype objective are compared to counts obtained with a standard microscope over matched fields of view. Two sets of 20 smears, positive and negative, are diagnosed by 2 pathologists as sputum smear positive or sputum smear negative, using both a standard clinical microscope and the prototype objective under evaluation. The results are compared to a reference diagnosis of the same sample. More bacteria are counted in matched fields of view in digital images taken with the prototype objective than with the standard clinical microscope. All diagnostic results are found to be highly concordant. An array microscope built with this miniature lens design will be able to detect M tuberculosis with high sensitivity and specificity.

  1. SOTB Implementation of a Field Programmable Gate Array with Fine-Grained Vt Programmability

    Directory of Open Access Journals (Sweden)

    Masakazu Hioki

    2014-07-01

    Full Text Available Field programmable gate arrays (FPGAs are one of the most widespread reconfigurable devices in which various functions can be implemented by storing circuit connection information and logic values into configuration memories. One of the most important issues in the modern FPGA is the reduction of its static leakage power consumption. Flex Power FPGA, which has been proposed to overcome this problem, uses a body biasing technique to implement the fine-grained threshold voltage (Vt programmability in the FPGA. A low-Vt state can be assigned only to the component circuits along the critical path of the application design mapped on the FPGA, so that the static leakage power consumption can be reduced drastically. Flex Power FPGA is an important application target for the SOTB (silicon on thin buried oxide device, which features a wide-range body biasing ability and the high sensitivity of Vt variation by body biasing, resulting in a drastic subthreshold leakage current reduction caused by static leakage power. In this paper, the Flex Power FPGA test chip is fabricated in SOTB technology, and the functional test and performance evaluation of a mapped 32-bit binary counter circuit are performed successfully. As a result, a three orders of magnitude static leakage reduction with a bias range of 2.1 V demonstrates the excellent Vt controllability of the SOTB transistors, and the 1.2 V bias difference achieves a 50× leakage reduction without degrading speed.

  2. Chemical imaging of cotton fibers using an infrared microscope and a focal-plane array detector

    Science.gov (United States)

    In this presentation, the chemical imaging of cotton fibers with an infrared microscope and a Focal-Plane Array (FPA) detector will be discussed. Infrared spectroscopy can provide us with information on the structure and quality of cotton fibers. In addition, FPA detectors allow for simultaneous spe...

  3. Three-dimensional light field microscope based on a lenslet array

    Science.gov (United States)

    Zhang, Mei; Geng, Zheng; Pei, Renjing; Cao, Xuan; Zhang, Zhaoxing

    2017-11-01

    Most conventional microscopes can only acquire two-dimensional (2D) images. However, there is increasing demand for microscopes capable of acquiring three-dimensional (3D) images for use in biological research. To improve observations of in vivo specimens, we develop a novel one snap-shot 3D light field microscope with high spatial resolution. By adding a lenslet array and focusing optics into the optical train of a conventional microscope, we are able to simultaneously capture seven sub-aperture images from different perspectives in a single shot, and finish 3D surface reconstruction of the specimen. In this paper, we present a functioning prototype of a novel 3D light field microscope using different objectives, and describe its design and image quality. During 3D image reconstruction, we use an optical flow method and back-projection interpolation to improve the resolution of the subimages. The performance of the novel light field microscope is analyzed theoretically and experimentally. Multiple perspective images are obtained using an objective with 20 × /NA 0.4. These images are 1050 × 1050 pixels with a depth of view of 200 μm. For our microscope, the highest resolvable group of USAF 1951 target is about group 7.5. 3D reconstructions of various specimens are successfully created using these images. This novel microscopy system is suitable for various applications in 3D imaging and optical metrology.

  4. On-axis programmable microscope using liquid crystal spatial light modulator

    Science.gov (United States)

    García-Martínez, Pascuala; Martínez, José Luís.; Moreno, Ignacio

    2017-06-01

    Spatial light modulators (SLM) are currently used in many applications in optical microscopy and imaging. One of the most promising methods is the use of liquid crystal displays (LCD) as programmable phase diffractive optical elements (DOE) placed in the Fourier plane giving access to the spatial frequencies which can be phased shifted individually, allowing to emulate a wealth of contrast enhancing methods for both amplitude and phase samples. We use phase and polarization modulation of LCD to implement an on-axis microscope optical system. The LCD used are Hamamatsu liquid crystal on silicon (LCOS) SLM free of flicker, thus showing a full profit of the SLM space bandwidth, as opposed to optical systems in the literature forced to work off-axis due to the strong zero-order component. Taking benefits of the phase modulation of the LCOS we have implemented different microscopic imaging operations, such as high-pass and low-pass filtering in parallel using programmable blazed gratings. Moreover, we are able to control polarization modulation to display two orthogonal linear state of polarization images than can be subtracted or added by changing the period of the blazed grating. In that sense, Differential Interference Contrast (DIC) microscopy can be easily done by generating two images exploiting the polarization splitting properties when a blazed grating is displayed in the SLM. Biological microscopy samples are also used.

  5. A programmable front-end system for arrays of bolometers

    Science.gov (United States)

    Alessandrello, A.; Brofferio, C.; Bucci, C.; Cremonesi, O.; Giuliani, A.; Nucciotti, A.; Pavan, M.; Perego, M.; Pessina, G.; Pirro, S.; Previtali, E.; Vanzini, M.

    2000-04-01

    We report on a new front-end system developed to readout an array of large mass bolometers. The front-end allows setting all the necessary parameters for each detector by remote control. A special circuit, also fired remotely, has been developed in order to adjust the output voltage, allowing the DC coupling to the detector.

  6. A programmable front-end system for arrays of bolometers

    Energy Technology Data Exchange (ETDEWEB)

    Alessandrello, A.; Brofferio, C.; Bucci, C.; Cremonesi, O.; Giuliani, A.; Nucciotti, A.; Pavan, M.; Perego, M.; Pessina, G. E-mail: pessina@mi.infn.it; Pirro, S.; Previtali, E.; Vanzini, M

    2000-04-07

    We report on a new front-end system developed to readout an array of large mass bolometers. The front-end allows setting all the necessary parameters for each detector by remote control. A special circuit, also fired remotely, has been developed in order to adjust the output voltage, allowing the DC coupling to the detector.

  7. A simple laser locking system based on a field-programmable gate array

    DEFF Research Database (Denmark)

    Jørgensen, Nils Byg; Birkmose, Danny Matthiesen; Trelborg, Kristian

    2016-01-01

    such locking systems. We have developed a frequency stabilization system based on a field-programmable gate array, with emphasis on hardware simplicity, which offers a user-friendly alternative to commercial and previous home-built solutions. Frequency modulation, lock-in detection and a proportional-integral......Frequency stabilization of laser light is crucial in both scientific and industrial applications. Technological developments now allow analog laser stabilization systems to be replaced with digital electronics such as field-programmable gate arrays, which have recently been utilized to develop......-derivative controller are programmed on the field-programmable gate array and only minimal additional components are required to frequency stabilize a laser. The locking system is administered from a host-computer which provides comprehensive, long-distance control through a versatile interface. Various measurements...

  8. An Undergraduate Course and Laboratory in Digital Signal Processing with Field Programmable Gate Arrays

    Science.gov (United States)

    Meyer-Base, U.; Vera, A.; Meyer-Base, A.; Pattichis, M. S.; Perry, R. J.

    2010-01-01

    In this paper, an innovative educational approach to introducing undergraduates to both digital signal processing (DSP) and field programmable gate array (FPGA)-based design in a one-semester course and laboratory is described. While both DSP and FPGA-based courses are currently present in different curricula, this integrated approach reduces the…

  9. Analog Module Architecture for Space-Qualified Field-Programmable Mixed-Signal Arrays

    Science.gov (United States)

    Edwards, R. Timothy; Strohbehn, Kim; Jaskulek, Steven E.; Katz, Richard

    1999-01-01

    Spacecraft require all manner of both digital and analog circuits. Onboard digital systems are constructed almost exclusively from field-programmable gate array (FPGA) circuits providing numerous advantages over discrete design including high integration density, high reliability, fast turn-around design cycle time, lower mass, volume, and power consumption, and lower parts acquisition and flight qualification costs. Analog and mixed-signal circuits perform tasks ranging from housekeeping to signal conditioning and processing. These circuits are painstakingly designed and built using discrete components due to a lack of options for field-programmability. FPAA (Field-Programmable Analog Array) and FPMA (Field-Programmable Mixed-signal Array) parts exist but not in radiation-tolerant technology and not necessarily in an architecture optimal for the design of analog circuits for spaceflight applications. This paper outlines an architecture proposed for an FPAA fabricated in an existing commercial digital CMOS process used to make radiation-tolerant antifuse-based FPGA devices. The primary concerns are the impact of the technology and the overall array architecture on the flexibility of programming, the bandwidth available for high-speed analog circuits, and the accuracy of the components for high-performance applications.

  10. Digital model of TiO(2 memristor for field-programmable gate array

    Directory of Open Access Journals (Sweden)

    Guangyi Wang

    2014-03-01

    Full Text Available A digital model which imitates the behaviour of a TiO(2 memristor as a new block in Alter DSP Builder is proposed in this Letter. The proposed model can be used as an independent memristor unit working with other units for designing memristor circuits based on field-programmable gate array. The accuracy of the digital model is confirmed not only by simulations, but also by hardwire experiments.

  11. Implementing a Microcontroller Watchdog with a Field-Programmable Gate Array (FPGA)

    Science.gov (United States)

    Straka, Bartholomew

    2013-01-01

    Reliability is crucial to safety. Redundancy of important system components greatly enhances reliability and hence safety. Field-Programmable Gate Arrays (FPGAs) are useful for monitoring systems and handling the logic necessary to keep them running with minimal interruption when individual components fail. A complete microcontroller watchdog with logic for failure handling can be implemented in a hardware description language (HDL.). HDL-based designs are vendor-independent and can be used on many FPGAs with low overhead.

  12. Examination of cotton fibers and common contaminants using an infrared microscope and a focal-plane array detector

    Science.gov (United States)

    The chemical imaging of cotton fibers and common contaminants in fibers is presented. Chemical imaging was performed with an infrared microscope equipped with a Focal-Plane Array (FPA) detector. Infrared spectroscopy can provide us with information on the structure and quality of cotton fibers. In a...

  13. A high throughput array microscope for the mechanical characterization of biomaterials

    Science.gov (United States)

    Cribb, Jeremy; Osborne, Lukas D.; Hsiao, Joe Ping-Lin; Vicci, Leandra; Meshram, Alok; O'Brien, E. Tim; Spero, Richard Chasen; Taylor, Russell; Superfine, Richard

    2015-02-01

    In the last decade, the emergence of high throughput screening has enabled the development of novel drug therapies and elucidated many complex cellular processes. Concurrently, the mechanobiology community has developed tools and methods to show that the dysregulation of biophysical properties and the biochemical mechanisms controlling those properties contribute significantly to many human diseases. Despite these advances, a complete understanding of the connection between biomechanics and disease will require advances in instrumentation that enable parallelized, high throughput assays capable of probing complex signaling pathways, studying biology in physiologically relevant conditions, and capturing specimen and mechanical heterogeneity. Traditional biophysical instruments are unable to meet this need. To address the challenge of large-scale, parallelized biophysical measurements, we have developed an automated array high-throughput microscope system that utilizes passive microbead diffusion to characterize mechanical properties of biomaterials. The instrument is capable of acquiring data on twelve-channels simultaneously, where each channel in the system can independently drive two-channel fluorescence imaging at up to 50 frames per second. We employ this system to measure the concentration-dependent apparent viscosity of hyaluronan, an essential polymer found in connective tissue and whose expression has been implicated in cancer progression.

  14. Influence of Alternate Biasing on TID Effects of Irradiated Mixed-Signal Programmable Arrays

    Science.gov (United States)

    Balen, Tiago R.; Vaz, Rafael G.; Fernandes, Gustavo S.; Gonçalez, Odair L.

    2016-08-01

    This work investigates the influence of alternate biasing on TID effects in mixed-signal programmable devices. By reducing the time the device is biased when exposed to ionizing radiation, the severity of TID effects is also reduced, due to the increasing in the initial recombination of electron-hole pairs and the radiation induced charge neutralization effect. These effects are investigated considering a switched capacitor filter prototyped in a Field Programmable Analog Array. Eight samples of such device were exposed to gamma radiation while the devices were alternately biased, by repeatedly turning the power on and off, corresponding to different equivalent total biasing times and duty-cycles. Results show increase in radiation tolerance to the alternate biased devices, which is dependent also on the biasing duty-cycle. Considering this behavior, a novel system level radiation hardening technique, based on modular redundancy, associated to an alternate biasing scheme, is also proposed in this paper.

  15. Rapid Prototyping of Field Programmable Gate Array-Based Discrete Cosine Transform Approximations

    Directory of Open Access Journals (Sweden)

    Trevor W. Fox

    2003-05-01

    Full Text Available A method for the rapid design of field programmable gate array (FPGA-based discrete cosine transform (DCT approximations is presented that can be used to control the coding gain, mean square error (MSE, quantization noise, hardware cost, and power consumption by optimizing the coefficient values and datapath wordlengths. Previous DCT design methods can only control the quality of the DCT approximation and estimates of the hardware cost by optimizing the coefficient values. It is shown that it is possible to rapidly prototype FPGA-based DCT approximations with near optimal coding gains that satisfy the MSE, hardware cost, quantization noise, and power consumption specifications.

  16. COMPARATIVE STUDY OF MAXIMUM POWER POINT TRACKING USING LINEAR KALMAN FILTER & UNSCENTED KALMAN FILTER FOR SOLAR PHOTOVOLTAIC ARRAY ON FIELD PROGRAMMABLE GATE ARRAY

    OpenAIRE

    Ramchandani, Varun; Pamarthi, Kranthi; Chowdhury, Shubhajit Roy

    2012-01-01

    The paper proposes comparative study of Field Programmable Gate Array implementation of 2 closely related approaches to track maximum power point of a solar photovoltaic array. The current work uses 2 versions of kalman filter viz. linear kalman filter and unscented kalman filter to track maximum power point. Using either of these approach the maximum power point tracking (MPPT) becomes much faster than using the conventional Perturb & Observe approach specifically in case of sudden weather c...

  17. A digital magnetic resonance imaging spectrometer using digital signal processor and field programmable gate array.

    Science.gov (United States)

    Liang, Xiao; Binghe, Sun; Yueping, Ma; Ruyan, Zhao

    2013-05-01

    A digital spectrometer for low-field magnetic resonance imaging is described. A digital signal processor (DSP) is utilized as the pulse programmer on which a pulse sequence is executed as a subroutine. Field programmable gate array (FPGA) devices that are logically mapped into the external addressing space of the DSP work as auxiliary controllers of gradient control, radio frequency (rf) generation, and rf receiving separately. The pulse programmer triggers an event by setting the 32-bit control register of the corresponding FPGA, and then the FPGA automatically carries out the event function according to preset configurations in cooperation with other devices; accordingly, event control of the spectrometer is flexible and efficient. Digital techniques are in widespread use: gradient control is implemented in real-time by a FPGA; rf source is constructed using direct digital synthesis technique, and rf receiver is constructed using digital quadrature detection technique. Well-designed performance is achieved, including 1 μs time resolution of the gradient waveform, 1 μs time resolution of the soft pulse, and 2 MHz signal receiving bandwidth. Both rf synthesis and rf digitalization operate at the same 60 MHz clock, therefore, the frequency range of transmitting and receiving is from DC to ~27 MHz. A majority of pulse sequences have been developed, and the imaging performance of the spectrometer has been validated through a large number of experiments. Furthermore, the spectrometer is also suitable for relaxation measurement in nuclear magnetic resonance field.

  18. Nine-channel mid-power bipolar pulse generator based on a field programmable gate array

    Energy Technology Data Exchange (ETDEWEB)

    Haylock, Ben, E-mail: benjamin.haylock2@griffithuni.edu.au; Lenzini, Francesco; Kasture, Sachin; Fisher, Paul; Lobino, Mirko [Centre for Quantum Dynamics, Griffith University, Brisbane (Australia); Queensland Micro and Nanotechnology Centre, Griffith University, Brisbane (Australia); Streed, Erik W. [Centre for Quantum Dynamics, Griffith University, Brisbane (Australia); Institute for Glycomics, Griffith University, Gold Coast (Australia)

    2016-05-15

    Many channel arbitrary pulse sequence generation is required for the electro-optic reconfiguration of optical waveguide networks in Lithium Niobate. Here we describe a scalable solution to the requirement for mid-power bipolar parallel outputs, based on pulse patterns generated by an externally clocked field programmable gate array. Positive and negative pulses can be generated at repetition rates up to 80 MHz with pulse width adjustable in increments of 1.6 ns across nine independent outputs. Each channel can provide 1.5 W of RF power and can be synchronised with the operation of other components in an optical network such as light sources and detectors through an external clock with adjustable delay.

  19. Radiation-Hardened Circuitry Using Mask-Programmable Analog Arrays. Final Report

    Energy Technology Data Exchange (ETDEWEB)

    Britton, Jr., Charles L. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Ericson, Milton Nance [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Bobrek, Miljko [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Blalock, Benjamin [Univ. of Tennessee, Knoxville, TN (United States)

    2015-12-01

    As the recent accident at Fukushima Daiichi so vividly demonstrated, telerobotic technologies capable of withstanding high radiation environments need to be readily available to enable operations, repair, and recovery under severe accident scenarios where human entry is extremely dangerous or not possible. Telerobotic technologies that enable remote operation in high dose rate environments have undergone revolutionary improvement over the past few decades. However, much of this technology cannot be employed in nuclear power environments due the radiation sensitivity of the electronics and the organic insulator materials currently in use. This is the final report of the activities involving the NEET 2 project Radiation Hardened Circuitry Using Mask-Programmable Analog Arrays. We present a detailed functional block diagram of the proposed data acquisition system, the thought process leading to technical decisions, the implemented system, and the tested results from the systems. This system will be capable of monitoring at least three parameters of importance to nuclear reactor monitoring: temperature, radiation level, and pressure.

  20. Design and Implementation of Video Shot Detection on Field Programmable Gate Arrays

    Directory of Open Access Journals (Sweden)

    Jharna Majumdar

    2012-09-01

    Full Text Available Video has become an interactive medium of communication in everyday life. The sheer volume of video makes it extremely difficult to browse through and find the required data. Hence extraction of key frames from the video which represents the abstract of the entire video becomes necessary. The aim of the video shot detection is to find the position of the shot boundaries, so that key frames can be selected from each shot for subsequent processing such as video summarization, indexing etc. For most of the surveillance applications like video summery, face recognition etc., the hardware (real time implementation of these algorithms becomes necessary. Here in this paper we present the architecture for simultaneous accessing of consecutive frames, which are then used for the implementation of various Video Shot Detection algorithms. We also present the real time implementation of three video shot detection algorithms using the above mentioned architecture on FPGA (Field Programmable Gate Arrays.

  1. Field Programmable Gate Array for Implementation of Redundant Advanced Digital Feedback Control

    Science.gov (United States)

    King, K. D.

    2003-01-01

    The goal of this effort was to develop a digital motor controller using field programmable gate arrays (FPGAs). This is a more rugged approach than a conventional microprocessor digital controller. FPGAs typically have higher radiation (rad) tolerance than both the microprocessor and memory required for a conventional digital controller. Furthermore, FPGAs can typically operate at higher speeds. (While speed is usually not an issue for motor controllers, it can be for other system controllers.) Other than motor power, only a 3.3-V digital power supply was used in the controller; no analog bias supplies were used. Since most of the circuit was implemented in the FPGA, no additional parts were needed other than the power transistors to drive the motor. The benefits that FPGAs provide over conventional designs-lower power and fewer parts-allow for smaller packaging and reduced weight and cost.

  2. Field Programmable Gate Array Reliability Analysis Using the Dynamic Flowgraph Methodology

    Directory of Open Access Journals (Sweden)

    Phillip McNelles

    2016-10-01

    Full Text Available Field programmable gate array (FPGA-based systems are thought to be a practical option to replace certain obsolete instrumentation and control systems in nuclear power plants. An FPGA is a type of integrated circuit, which is programmed after being manufactured. FPGAs have some advantages over other electronic technologies, such as analog circuits, microprocessors, and Programmable Logic Controllers (PLCs, for nuclear instrumentation and control, and safety system applications. However, safety-related issues for FPGA-based systems remain to be verified. Owing to this, modeling FPGA-based systems for safety assessment has now become an important point of research. One potential methodology is the dynamic flowgraph methodology (DFM. It has been used for modeling software/hardware interactions in modern control systems. In this paper, FPGA logic was analyzed using DFM. Four aspects of FPGAs are investigated: the “IEEE 1164 standard,” registers (D flip-flops, configurable logic blocks, and an FPGA-based signal compensator. The ModelSim simulations confirmed that DFM was able to accurately model those four FPGA properties, proving that DFM has the potential to be used in the modeling of FPGA-based systems. Furthermore, advantages of DFM over traditional reliability analysis methods and FPGA simulators are presented, along with a discussion of potential issues with using DFM for FPGA-based system modeling.

  3. Field programmable gate array reliability analysis using the dynamic flow graph methodology

    Energy Technology Data Exchange (ETDEWEB)

    McNelles, Phillip; Lu, Lixuan [Faculty of Energy Systems and Nuclear Science, University of Ontario Institute of Technology (UOIT), Ontario (Canada)

    2016-10-15

    Field programmable gate array (FPGA)-based systems are thought to be a practical option to replace certain obsolete instrumentation and control systems in nuclear power plants. An FPGA is a type of integrated circuit, which is programmed after being manufactured. FPGAs have some advantages over other electronic technologies, such as analog circuits, microprocessors, and Programmable Logic Controllers (PLCs), for nuclear instrumentation and control, and safety system applications. However, safety-related issues for FPGA-based systems remain to be verified. Owing to this, modeling FPGA-based systems for safety assessment has now become an important point of research. One potential methodology is the dynamic flowgraph methodology (DFM). It has been used for modeling software/hardware interactions in modern control systems. In this paper, FPGA logic was analyzed using DFM. Four aspects of FPGAs are investigated: the 'IEEE 1164 standard', registers (D flip-flops), configurable logic blocks, and an FPGA-based signal compensator. The ModelSim simulations confirmed that DFM was able to accurately model those four FPGA properties, proving that DFM has the potential to be used in the modeling of FPGA-based systems. Furthermore, advantages of DFM over traditional reliability analysis methods and FPGA simulators are presented, along with a discussion of potential issues with using DFM for FPGA-based system modeling.

  4. Enhanced depth-of-field of an integral imaging microscope using a bifocal holographic optical element-micro lens array.

    Science.gov (United States)

    Kwon, Ki-Chul; Lim, Young-Tae; Shin, Chang-Won; Erdenebat, Munkh-Uchral; Hwang, Jae-Moon; Kim, Nam

    2017-08-15

    We propose and implement an integral imaging microscope with extended depth-of-field (DoF) using a bifocal holographic micro lens array (MLA). The properties of the two MLAs are switched via peristrophic multiplexing, where different properties of the MLA are recorded onto the single holographic optical element (HOE). The recorded MLA properties are perpendicular to each other: after the first mode is recorded, the HOE is rotated by 90° clockwise, and the second mode is recorded. The experimental results confirm that the DoF of the integral imaging microscopy system is extended successfully by using the bifocal MLA.

  5. Discovering Protein-Protein Interactions Using Nucleic Acid Programmable Protein Arrays.

    Science.gov (United States)

    Tang, Yanyang; Qiu, Ji; Machner, Matthias; LaBaer, Joshua

    2017-03-03

    We have developed a protocol enabling the study of protein-protein interactions (PPIs) at the proteome level using in vitro-synthesized proteins. Assay preparation requires molecular cloning of the query gene into a vector that supports in vitro transcription/translation (IVTT) and appends a HaloTag to the query protein of interest. In parallel, protein microarrays are prepared by printing plasmids encoding glutathione S-transferase (GST)-tagged target proteins onto a carrier matrix/glass slide coated with antibody directed against GST. At the time of the experiment, the query protein and the target protein are produced separately through IVTT. The query protein is then applied to nucleic acid programmable protein arrays (NAPPA) that display thousands of freshly produced target proteins captured by anti-GST antibody. Interactions between the query and immobilized target proteins are detected through addition of a fluorophore-labeled HaloTag ligand. Our protocol allows the elucidation of PPIs in a high-throughput fashion using proteins produced in vitro, obviating the scientific challenges, high cost, and laborious work, as well as concerns about protein stability, which are usually present in protocols using conventional protein arrays. © 2017 by John Wiley & Sons, Inc. Copyright © 2017 John Wiley & Sons, Inc.

  6. Field-programmable gate array-controlled sweep velocity-locked laser pulse generator

    Science.gov (United States)

    Chen, Zhen; Hefferman, Gerald; Wei, Tao

    2017-05-01

    A field-programmable gate array (FPGA)-controlled sweep velocity-locked laser pulse generator (SV-LLPG) design based on an all-digital phase-locked loop (ADPLL) is proposed. A distributed feedback laser with modulated injection current was used as a swept-frequency laser source. An open-loop predistortion modulation waveform was calibrated using a feedback iteration method to initially improve frequency sweep linearity. An ADPLL control system was then implemented using an FPGA to lock the output of a Mach-Zehnder interferometer that was directly proportional to laser sweep velocity to an on-board system clock. Using this system, linearly chirped laser pulses with a sweep bandwidth of 111.16 GHz were demonstrated. Further testing evaluating the sensing utility of the system was conducted. In this test, the SV-LLPG served as the swept laser source of an optical frequency-domain reflectometry system used to interrogate a subterahertz range fiber structure (sub-THz-FS) array. A static strain test was then conducted and linear sensor results were observed.

  7. Pulse Generator for Ultrasonic Piezoelectric Transducer Arrays Based on a Programmable System-on-Chip (PSoC

    Directory of Open Access Journals (Sweden)

    Pedro Acevedo

    2017-04-01

    Full Text Available This paper describes the design of a pulse generator to excite PZT and PVDF ultrasonic transducer arrays, based on the Programmable System-on-Chip (PSoC module. In this module, using programmable logic different pulses were implemented; these pulses are required in ultrasonic applications for multiple channels to excite PZT and PVDF transducer arrays. To excite multiple elements, bursts are required which can be generated simultaneously or out of phase, generating dynamic wave fronts. For medical applications where bidirectional blood flow is detected burst and quadrature pulses are used. These pulses can be generated independently or in combinations, as simultaneous pulses, shift pulses or burst. This module can operate with programmable frequencies from 3-74 MHz; its programming may be versatile covering a wide range of ultrasonic applications.

  8. Development and simulation of soft morphological operators for a field programmable gate array

    Science.gov (United States)

    Tickle, Andrew J.; Harvey, Paul K.; Smith, Jeremy S.; Wu, Q. Henry

    2013-04-01

    In image processing applications, soft mathematical morphology (MM) can be employed for both binary and grayscale systems and is derived from set theory. Soft MM techniques have improved behavior over standard morphological operations in noisy environments, as they can preserve small details within an image. This makes them suitable for use in image processing applications on portable field programmable gate arrays for tasks such as robotics and security. We explain how the systems were developed using Altera's DSP Builder in order to provide optimized code for the many different devices currently on the market. Also included is how the circuits can be inserted and combined with previously developed work in order to increase their functionality. The testing procedures involved loading different images into these systems and analyzing the outputs against MATLAB-generated validation images. A set of soft morphological operations are described, which can then be applied to various tasks and easily modified in size via altering the line buffer settings inside the system to accommodate a range of image attributes ranging from image sizes such as 320×240 pixels for basic webcam imagery up to high quality 4000×4000 pixel images for military applications.

  9. Feasibility of a portable morphological scene change detection security system for field programmable gate arrays (FPGA)

    Science.gov (United States)

    Tickle, Andrew J.; Smith, Jeremy S.; Wu, Q. Henry

    2008-04-01

    In this paper, there is an investigation into the possibility of executing a Morphological Scene Change Detection (MSCD) system on a Field Programmable Gate Array (FPGA), which would allow its set up in virtually any location, with its purpose to detect intruders and raise an alarm to call security personal, and a signal to initial a lockdown of the local area. This paper will include how the system was scaled down from the full building multi-computer system, to an FPGA without losing any functionality using Altera's DSP Builder development tool. Also included is the analysis of the different situations which the system would encounter in the field, and their respective alarm triggering levels, these include indoors, outdoors, close-up, distance, high-brightness, low-light, bad weather, etc. The triggering mechanism is a pixel counter and threshold system, and its adaptive design will be included. All the results shown in this paper, will also be verified by MATLAB m-files running on a full desktop PC, to show that the results obtained from the FPGA based system are accurate.

  10. Using field programmable gate array hardware for the performance improvement of ultrasonic wave propagation imaging system

    Energy Technology Data Exchange (ETDEWEB)

    Shan, Jaffry Syed [Hamdard University, Karachi (Pakistan); Abbas, Syed Haider; Lee, Jung Ryul [Dept. of Aerospace Engineering, Korea Advanced Institute of Science and Technology, Daejeon (Korea, Republic of); Kang, Dong Hoon [Advanced Materials Research Team, Korea Railroad Research Institute, Uiwang (Korea, Republic of)

    2015-12-15

    Recently, wave propagation imaging based on laser scanning-generated elastic waves has been intensively used for nondestructive inspection. However, the proficiency of the conventional software based system reduces when the scan area is large since the processing time increases significantly due to unavoidable processor multitasking, where computing resources are shared with multiple processes. Hence, the field programmable gate array (FPGA) was introduced for a wave propagation imaging method in order to obtain extreme processing time reduction. An FPGA board was used for the design, implementing post-processing ultrasonic wave propagation imaging (UWPI). The results were compared with the conventional system and considerable improvement was observed, with at least 78% (scanning of 100x100mm{sup 2} with 0.5 mm interval) to 87.5% (scanning of 200x200mm{sup 2} with 0.5 mm interval) less processing time, strengthening the claim for the research. This new concept to implement FPGA technology into the UPI system will act as a break-through technology for full-scale automatic inspection.

  11. Full image-processing pipeline in field-programmable gate array for a small endoscopic camera

    Science.gov (United States)

    Mostafa, Sheikh Shanawaz; Sousa, L. Natércia; Ferreira, Nuno Fábio; Sousa, Ricardo M.; Santos, Joao; Wäny, Martin; Morgado-Dias, F.

    2017-01-01

    Endoscopy is an imaging procedure used for diagnosis as well as for some surgical purposes. The camera used for the endoscopy should be small and able to produce a good quality image or video, to reduce discomfort of the patients, and to increase the efficiency of the medical team. To achieve these fundamental goals, a small endoscopy camera with a footprint of 1 mm×1 mm×1.65 mm is used. Due to the physical properties of the sensors and human vision system limitations, different image-processing algorithms, such as noise reduction, demosaicking, and gamma correction, among others, are needed to faithfully reproduce the image or video. A full image-processing pipeline is implemented using a field-programmable gate array (FPGA) to accomplish a high frame rate of 60 fps with minimum processing delay. Along with this, a viewer has also been developed to display and control the image-processing pipeline. The control and data transfer are done by a USB 3.0 end point in the computer. The full developed system achieves real-time processing of the image and fits in a Xilinx Spartan-6LX150 FPGA.

  12. Fast and robust control of nanopositioning systems: Performance limits enabled by field programmable analog arrays

    Science.gov (United States)

    Baranwal, Mayank; Gorugantu, Ram S.; Salapaka, Srinivasa M.

    2015-08-01

    This paper aims at control design and its implementation for robust high-bandwidth precision (nanoscale) positioning systems. Even though modern model-based control theoretic designs for robust broadband high-resolution positioning have enabled orders of magnitude improvement in performance over existing model independent designs, their scope is severely limited by the inefficacies of digital implementation of the control designs. High-order control laws that result from model-based designs typically have to be approximated with reduced-order systems to facilitate digital implementation. Digital systems, even those that have very high sampling frequencies, provide low effective control bandwidth when implementing high-order systems. In this context, field programmable analog arrays (FPAAs) provide a good alternative to the use of digital-logic based processors since they enable very high implementation speeds, moreover with cheaper resources. The superior flexibility of digital systems in terms of the implementable mathematical and logical functions does not give significant edge over FPAAs when implementing linear dynamic control laws. In this paper, we pose the control design objectives for positioning systems in different configurations as optimal control problems and demonstrate significant improvements in performance when the resulting control laws are applied using FPAAs as opposed to their digital counterparts. An improvement of over 200% in positioning bandwidth is achieved over an earlier digital signal processor (DSP) based implementation for the same system and same control design, even when for the DSP-based system, the sampling frequency is about 100 times the desired positioning bandwidth.

  13. Implementation of fractional order integrator/differentiator on field programmable gate array

    Directory of Open Access Journals (Sweden)

    K.P.S. Rana

    2016-06-01

    Full Text Available Concept of fractional order calculus is as old as the regular calculus. With the advent of high speed and cost effective computing power, now it is possible to model the real world control and signal processing problems using fractional order calculus. For the past two decades, applications of fractional order calculus, in system modeling, control and signal processing, have grown rapidly. This paper presents a systematic procedure for hardware implementation of the basic operators of fractional calculus i.e. fractional integrator and derivative, using Grünwald–Letnikov definition, on field programmable gate array (FPGA in LabVIEW environment. The simulation and hardware implementation results for fractional order integrator and derivative of sinusoid and square waveform signals for some selected fractional orders have been presented. A close agreement between the simulated and the experimental results demonstrated the suitability of FPGA device in fractional order control and signal processing applications. LabVIEW being one of the finest tools for measurement and control, and signal processing applications the fractional order operator implementation is expected to further enhance the capability of the tool to cater to the needs of advanced experimental research employing fractional order operators.

  14. Design techniques for a stable operation of cryogenic field-programmable gate arrays

    Science.gov (United States)

    Homulle, Harald; Visser, Stefan; Patra, Bishnu; Charbon, Edoardo

    2018-01-01

    In this paper, we show how a deep-submicron field-programmable gate array (FPGA) can be operated more stably at extremely low temperatures through special firmware design techniques. Stability at low temperatures is limited through long power supply wires and reduced performance of various printed circuit board components commonly employed at room temperature. Extensive characterization of these components shows that the majority of decoupling capacitor types and voltage regulators are not well behaved at cryogenic temperatures, asking for an ad hoc solution to stabilize the FPGA supply voltage, especially for sensitive applications. Therefore, we have designed a firmware that enforces a constant power consumption, so as to stabilize the supply voltage in the interior of the FPGA. The FPGA is powered with a supply at several meters distance, causing significant resistive voltage drop and thus fluctuations on the local supply voltage. To achieve the stabilization, the variation in digital logic speed, which directly corresponds to changes in supply voltage, is constantly measured and corrected for through a tunable oscillator farm, implemented on the FPGA. The impact of the stabilization technique is demonstrated together with a reconfigurable analog-to-digital converter (ADC), completely implemented in the FPGA fabric and operating at 15 K. The ADC performance can be improved by at most 1.5 bits (effective number of bits) thanks to the more stable supply voltage. The method is versatile and robust, enabling seamless porting to other FPGA families and configurations.

  15. Spatio-angular light control in microscopes using micro mirror arrays

    Science.gov (United States)

    Rückerl, F.; Bellow, S.; Berndt, D.; Tinevez, J.-Y.; Heber, J.; Wagner, M.; Shorte, S.

    2015-03-01

    Micromirror arrays (MMA) are spatial light modulators (SLM) used in a wide variety of applications for structured light manipulation i.e. structured illumination microscopy. In our setup, we use a combination of two micromirror arrays, which allow not only to spatially structure the light in the field of view, but also to control the direction and angle of the incident light. In order to achieve this, a first MMA is imaged in the focal plane and used as a black and white (or even greyscale) mask. With a fully illuminated objective, this image would normally be formed from the complete light cone. By imaging the second MMA onto the backfocal plane of the objective only a portion of the light cone is used to form the image. This enables avoiding the unwanted illumination of out of focus objects. The MMAs in our setup consist of an array of 256x256 micromirrors, that can each be individually and continuously tilted up to 450nm, allowing the creation of greyscale images in real time in the illumination pattern. The mirrors themselves can be tilted for times as short as 10μs up to several seconds. This gives unprecedented control over the illumination times and intensities in the sample. Furthermore, our enhanced coating technology yields a high reflectivity over a broad optical spectrum (240- 1000nm). Overall, the setup allows targetted illumination of subcellular regions enabling the precise, localized activation of optogenetic probes or the activation and deactivation of signaling cascades using photo-activated ion-channels.

  16. Fabrication of heterogeneous nanomaterial array by programmable heating and chemical supply within microfluidic platform towards multiplexed gas sensing application

    Science.gov (United States)

    Yang, Daejong; Kang, Kyungnam; Kim, Donghwan; Li, Zhiyong; Park, Inkyu

    2015-01-01

    A facile top-down/bottom-up hybrid nanofabrication process based on programmable temperature control and parallel chemical supply within microfluidic platform has been developed for the all liquid-phase synthesis of heterogeneous nanomaterial arrays. The synthesized materials and locations can be controlled by local heating with integrated microheaters and guided liquid chemical flow within microfluidic platform. As proofs-of-concept, we have demonstrated the synthesis of two types of nanomaterial arrays: (i) parallel array of TiO2 nanotubes, CuO nanospikes and ZnO nanowires, and (ii) parallel array of ZnO nanowire/CuO nanospike hybrid nanostructures, CuO nanospikes and ZnO nanowires. The laminar flow with negligible ionic diffusion between different precursor solutions as well as localized heating was verified by numerical calculation and experimental result of nanomaterial array synthesis. The devices made of heterogeneous nanomaterial array were utilized as a multiplexed sensor for toxic gases such as NO2 and CO. This method would be very useful for the facile fabrication of functional nanodevices based on highly integrated arrays of heterogeneous nanomaterials. PMID:25634814

  17. Fabrication of heterogeneous nanomaterial array by programmable heating and chemical supply within microfluidic platform towards multiplexed gas sensing application

    Science.gov (United States)

    Yang, Daejong; Kang, Kyungnam; Kim, Donghwan; Li, Zhiyong; Park, Inkyu

    2015-01-01

    A facile top-down/bottom-up hybrid nanofabrication process based on programmable temperature control and parallel chemical supply within microfluidic platform has been developed for the all liquid-phase synthesis of heterogeneous nanomaterial arrays. The synthesized materials and locations can be controlled by local heating with integrated microheaters and guided liquid chemical flow within microfluidic platform. As proofs-of-concept, we have demonstrated the synthesis of two types of nanomaterial arrays: (i) parallel array of TiO2 nanotubes, CuO nanospikes and ZnO nanowires, and (ii) parallel array of ZnO nanowire/CuO nanospike hybrid nanostructures, CuO nanospikes and ZnO nanowires. The laminar flow with negligible ionic diffusion between different precursor solutions as well as localized heating was verified by numerical calculation and experimental result of nanomaterial array synthesis. The devices made of heterogeneous nanomaterial array were utilized as a multiplexed sensor for toxic gases such as NO2 and CO. This method would be very useful for the facile fabrication of functional nanodevices based on highly integrated arrays of heterogeneous nanomaterials.

  18. Toward active-matrix lab-on-a-chip: programmable electrofluidic control enabled by arrayed oxide thin film transistors.

    Science.gov (United States)

    Noh, Joo Hyon; Noh, Jiyong; Kreit, Eric; Heikenfeld, Jason; Rack, Philip D

    2012-01-21

    Agile micro- and nano-fluidic control is critical to numerous life science and chemical science synthesis as well as kinetic and thermodynamic studies. To this end, we have demonstrated the use of thin film transistor arrays as an active matrix addressing method to control an electrofluidic array. Because the active matrix method minimizes the number of control lines necessary (m + n lines for the m×n element array), the active matrix addressing method integrated with an electrofluidic platform can be a significant breakthrough for complex electrofluidic arrays (increased size or resolution) with enhanced function, agility and programmability. An amorphous indium gallium zinc oxide (a-IGZO) semiconductor active layer is used because of its high mobility of 1-15 cm(2) V(-1) s(-1), low-temperature processing and transparency for potential spectroscopy and imaging. Several electrofluidic functionalities are demonstrated using a simple 2 × 5 electrode array connected to a 2 × 5 IGZO thin film transistor array with the semiconductor channel width of 50 μm and mobility of 6.3 cm(2) V(-1) s(-1). Additionally, using the TFT device characteristics, active matrix addressing schemes are discussed as the geometry of the electrode array can be tailored to act as a storage capacitor element. Finally, requisite material and device parameters are discussed in context with a VGA scale active matrix addressed electrofluidic platform.

  19. Single Event Test Methodologies and System Error Rate Analysis for Triple Modular Redundant Field Programmable Gate Arrays

    Science.gov (United States)

    Allen, Gregory; Edmonds, Larry D.; Swift, Gary; Carmichael, Carl; Tseng, Chen Wei; Heldt, Kevin; Anderson, Scott Arlo; Coe, Michael

    2010-01-01

    We present a test methodology for estimating system error rates of Field Programmable Gate Arrays (FPGAs) mitigated with Triple Modular Redundancy (TMR). The test methodology is founded in a mathematical model, which is also presented. Accelerator data from 90 nm Xilins Military/Aerospace grade FPGA are shown to fit the model. Fault injection (FI) results are discussed and related to the test data. Design implementation and the corresponding impact of multiple bit upset (MBU) are also discussed.

  20. Design and Performance of a TES X-ray Microcalorimeter Array for Energy Dispersive Spectroscopy on Scanning Transmission Electron Microscope

    Science.gov (United States)

    Muramatsu, Haruka; Nagayoshi, K.; Hayashi, T.; Sakai, K.; Yamamoto, R.; Mitsuda, K.; Yamasaki, N. Y.; Maehata, K.; Hara, T.

    2016-07-01

    We discuss the design and performance of a transition edge sensor (TES) X-ray microcalorimeter array for scanning transmission electron microscope (STEM)-energy dispersive X-ray spectroscopy (EDS). The TES X-ray microcalorimeter has better energy resolution compared to conventional silicon drift detector and STEM-EDS utilizing a TES detector makes it possible to map the distribution of elements on a specimen in addition to analyze the composition. The requirement for a TES detector is a high counting rate (>20 kcps), wide energy band (0.5-15 keV) and good energy resolution (<10 eV) full width at half maximum. The major improvement of this development is to increase the maximum counting rate. In order to accommodate the high counting rate, we adopted an 8 × 8 format, 64-pixel array and common biasing scheme for the readout method. We did all design and fabrication of the device in house. With the device we have fabricated most recently, the pulse decay time is 40 \\upmu s which is expected to achieve 50 kcps. For a single pixel, the measured energy resolution was 7.8 eV at 5.9 keV. This device satisfies the requirements of counting rate and energy resolution, although several issues remain where the performance must be confirmed.

  1. Implementation of a high resolution (< 11 ps RMS) Time-to-Digital Converter in a Field Programmable Gate Array

    Energy Technology Data Exchange (ETDEWEB)

    Ugur, Cahit [Helmholtz-Institut Mainz, Johannes Gutenberg-Universitaet Mainz (Germany); Bayer, Eugen [Department for Digital Electronics, University Kassel (Germany); Kurz, Nikolaus; Traxler, Michael [GSI Helmholtz Centre for Heavy Ion Research, Darmstadt (Germany); Michel, Jan [Institute for Nuclear Physics, Goethe University Frankfurt, Frankfurt am Main (Germany)

    2012-07-01

    A high resolution time-to-digital converter (TDC) was implemented in a general purpose field-programmable gate array (FPGA), a re-programmable digital chip. RMS and the time resolution of different channels are calculated for one clock cycle (5 ns) interval and a minimum of 10.3 ps RMS on two channels is achieved, which yields to a time resolution of 7.3 ps (10.3 ps/{radical}(2)) on a single channel. The TDC can be used in time-of-flight, time-over-threshold, drift time measurement applications as well as many other measurements with specific Front-End Electronics (FEE), e.g. charge measurements with charge-to-width (Q2W) FEE. The re-programmable flexibility of FPGAs also allows to have application specific features, e.g. trigger window, zero dead time etc.

  2. The Use of Field Programmable Gate Arrays (FPGA) in Small Satellite Communication Systems

    Science.gov (United States)

    Varnavas, Kosta; Sims, William Herbert; Casas, Joseph

    2015-01-01

    This paper will describe the use of digital Field Programmable Gate Arrays (FPGA) to contribute to advancing the state-of-the-art in software defined radio (SDR) transponder design for the emerging SmallSat and CubeSat industry and to provide advances for NASA as described in the TAO5 Communication and Navigation Roadmap (Ref 4). The use of software defined radios (SDR) has been around for a long time. A typical implementation of the SDR is to use a processor and write software to implement all the functions of filtering, carrier recovery, error correction, framing etc. Even with modern high speed and low power digital signal processors, high speed memories, and efficient coding, the compute intensive nature of digital filters, error correcting and other algorithms is too much for modern processors to get efficient use of the available bandwidth to the ground. By using FPGAs, these compute intensive tasks can be done in parallel, pipelined fashion and more efficiently use every clock cycle to significantly increase throughput while maintaining low power. These methods will implement digital radios with significant data rates in the X and Ka bands. Using these state-of-the-art technologies, unprecedented uplink and downlink capabilities can be achieved in a 1/2 U sized telemetry system. Additionally, modern FPGAs have embedded processing systems, such as ARM cores, integrated inside the FPGA allowing mundane tasks such as parameter commanding to occur easily and flexibly. Potential partners include other NASA centers, industry and the DOD. These assets are associated with small satellite demonstration flights, LEO and deep space applications. MSFC currently has an SDR transponder test-bed using Hardware-in-the-Loop techniques to evaluate and improve SDR technologies.

  3. programme

    African Journals Online (AJOL)

    Aid for AIDS (AfA) is a disease management programme (DIVIPI available to beneficiaries and employees of contracted medical funds and ... the challenges alluded to in the first article, including late enrolment and the measurement of survival, especially in patients with ... I the HIV prevalence and incidence (new infections].

  4. Radiation-Hardened Circuitry Using Mask-Programmable Analog Arrays. Report 3

    Energy Technology Data Exchange (ETDEWEB)

    Britton, Jr, Charles L. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Shelton, Jacob H. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Ericson, Milton Nance [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Blalock, Benjamin [Univ. of Tennessee, Knoxville, TN (United States)

    2015-03-01

    As the recent accident at Fukushima Daiichi so vividly demonstrated, telerobotic technologies capable of withstanding high radiation environments need to be readily available to enable operations, repair, and recovery under severe accident scenarios when human entry is extremely dangerous or not possible. Telerobotic technologies that enable remote operation in high dose rate environments have undergone revolutionary improvement over the past few decades. However, much of this technology cannot be employed in nuclear power environments because of the radiation sensitivity of the electronics and the organic insulator materials currently in use. This is a report of the activities involving Task 3 of the Nuclear Energy Enabling Technologies (NEET) 2 project Radiation Hardened Circuitry Using Mask-Programmable Analog Arrays [1]. Evaluation of the performance of the system for both pre- and post-irradiation as well as operation at elevated temperature will be performed. Detailed performance of the system will be documented to ensure the design meets requirements prior to any extended evaluation. A suite of tests will be developed which will allow evaluation before and after irradiation and during temperature. Selection of the radiation exposure facilities will be determined in the early phase of the project. Radiation exposure will consist of total integrated dose (TID) up to 200 kRad or above with several intermediate doses during test. Dose rates will be in various ranges determined by the facility that will be used with a target of 30 kRad/hr. Many samples of the pre-commercial devices to be used will have been tested in previous projects to doses of at least 300 kRad and temperatures up to 125C. The complete systems will therefore be tested for performance at intermediate doses. Extended temperature testing will be performed up to the limit of the commercial sensors. The test suite performed at each test point will consist of operational testing of the three basic

  5. Modelling of critical functions of nuclear reactors using Fild Programmable Gate Array; Modelagem de funcoes criticas de reatores nucleares utilizando Fild Programmable Gate Array

    Energy Technology Data Exchange (ETDEWEB)

    Teixeira, Pamela Iara Nolasco

    2016-07-01

    This paper proposes the development of a method using FPGA for critical security functions of a nuclear reactor. It was implemented two critical safety functions in VHDL, which is a way to describe, through a program, the behavior of a circuit or digital component. Two critical security functions, FCS Core Cooling, responsible for cooling the reactor core in the charts of the plant and also in the event of accidents involving loss of coolant and FCS Heat Transfer, responsible for cooling the reactor core in the event an accident with loss of coolant were implemented. In this Dissertation it was chosen the use of FPGA, because - due to the effects of aging, obsolescence issues, environmental degradation and mechanical failures - nuclear power plants need to replace their older systems by new ones based on digital technology. The technologies obtained using a system described in hardware language can be implemented in a programmable device, having the advantage of changing the code at any time. (author)

  6. A field-programmable gate array based system for high frame rate laser Doppler blood flow imaging.

    Science.gov (United States)

    Nguyen, H C; Hayes-Gill, B R; Morgan, S P; Zhu, Y; Boggett, D; Huang, X; Potter, M

    2010-01-01

    This paper presents a general embedded processing system implemented in a field-programmable gate array providing high frame rate and high accuracy for a laser Doppler blood flow imaging system. The proposed system can achieve a basic frame rate of flow images at 1 frame/second for 256 x 256 images with 1024 fast Fourier transform (FFT) points used in the processing algorithm. Mixed fixed-floating point calculations are utilized to achieve high accuracy but with a reasonable resource usage. The implementation has a root mean square deviation of the relative difference in flow values below 0.1% when compared with a double-precision floating point implementation. The system can contain from one or more processing units to obtain the required frame rate and accuracy. The performance of the system is significantly higher than other methods reported to date. Furthermore, a dedicated field-programmable gate array (FPGA) board has been designed to test the proposed processing system. The board is linked with a laser line scanning system, which uses a 64 x 1 photodetector array. Test results with various operating parameters show that the performance of the new system is better, in terms of noise and imaging speed, than has been previously achieved.

  7. A New Universal Second-Order Filter using Configurable Analog Building Blocks (CABs for Filed-Programmable Analogue Arrays

    Directory of Open Access Journals (Sweden)

    M. T. Abuelma'atti

    2011-06-01

    Full Text Available In this paper, the design of a universal second-order filter using configurable analog blocks (CABs for field programmable analog arrays is presented. The configurable blocks are capable of performing integration, differentiation, amplification, log, anti-log, add and negate functions. To maintain high frequency operation, the programmability and configurability of the blocks are achieved by digitally modifying the block's biasing conditions. Using at most four CABs, this article shows that it is possible to design a versatile second-order filter realizing all the standard five filter functions; lowpass, highpass, bandpass, notch and allpass. SPICE simulation results using practical bipolar junction transistor (BJT parameters confirm the feasibility of using the CABs in designing second-order filters.

  8. A flexible 32-channel time-to-digital converter implemented in a Xilinx Zynq-7000 field programmable gate array

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Yonggang, E-mail: wangyg@ustc.edu.cn; Kuang, Jie; Liu, Chong; Cao, Qiang; Li, Deng

    2017-03-01

    A high performance multi-channel time-to-digital converter (TDC) is implemented in a Xilinx Zynq-7000 field programmable gate array (FPGA). It can be flexibly configured as either 32 TDC channels with 9.9 ps time-interval RMS precision, 16 TDC channels with 6.9 ps RMS precision, or 8 TDC channels with 5.8 ps RMS precision. All TDCs have a 380 M Samples/second measurement throughput and a 2.63 ns measurement dead time. The performance consistency and temperature dependence of TDC channels are also evaluated. Because Zynq-7000 FPGA family integrates a feature-rich dual-core ARM based processing system and 28 nm Xilinx programmable logic in a single device, the realization of high performance TDCs on it will make the platform more widely used in time-measuring related applications.

  9. Evaluation of the Leon3 soft-core processor within a Xilinx radiation-hardened field-programmable gate array.

    Energy Technology Data Exchange (ETDEWEB)

    Learn, Mark Walter

    2012-01-01

    The purpose of this document is to summarize the work done to evaluate the performance of the Leon3 soft-core processor in a radiation environment while instantiated in a radiation-hardened static random-access memory based field-programmable gate array. This evaluation will look at the differences between two soft-core processors: the open-source Leon3 core and the fault-tolerant Leon3 core. Radiation testing of these two cores was conducted at the Texas A&M University Cyclotron facility and Lawrence Berkeley National Laboratory. The results of these tests are included within the report along with designs intended to improve the mitigation of the open-source Leon3. The test setup used for evaluating both versions of the Leon3 is also included within this document.

  10. Note: A high-frequency signal generator based on direct digital synthesizer and field-programmable gate array

    Science.gov (United States)

    Du, Yuanbo; Li, Wenbing; Ge, Yapeng; Li, Hui; Deng, Ke; Lu, Zehuang

    2017-09-01

    A high-frequency signal generator based on direct digital synthesizer (DDS) and field-programmable gate array (FPGA) is presented. The FPGA provides the controlling time sequence for the DDS, which has a highest output frequency of 1.4 GHz and a frequency resolution of 190 pHz. At an output frequency of 1.2 GHz, the measured phase noise, including the contribution of the reference clock, is -65 dBc/Hz@1 Hz, while the intrinsic phase noise is -82 dBc/Hz@1 Hz. Time delay of the DDS is measured to be less than 150 ns. The signal generator is used to drive an acousto-optic modulator, and the rise time due to the whole link is 24 ns. The developed signal generator can be used in many precision measurement experiments in the fields of atomic, molecular, and optical physics.

  11. Real-time processing of fast-scan cyclic voltammetry (FSCV) data using a field-programmable gate array (FPGA).

    Science.gov (United States)

    Bozorgzadeh, Bardia; Covey, Daniel P; Heidenreich, Byron A; Garris, Paul A; Mohseni, Pedram

    2014-01-01

    This paper reports the hardware implementation of a digital signal processing (DSP) unit for real-time processing of data obtained by fast-scan cyclic voltammetry (FSCV) at a carbon-fiber microelectrode (CFM), an electrochemical transduction technique for high-resolution monitoring of brain neurochemistry. Implemented on a field-programmable gate array (FPGA), the DSP unit comprises a decimation filter and an embedded processor to process the oversampled FSCV data and obtain in real time a temporal profile of concentration variation along with a chemical signature to identify the target neurotransmitter. Interfaced with an integrated, FSCV-sensing front-end, the DSP unit can successfully process FSCV data obtained by bolus injection of dopamine in a flow cell as well as electrically evoked, transient dopamine release in the dorsal striatum of an anesthetized rat.

  12. Programmable large area digital microfluidic array with integrated droplet sensing for bioassays.

    Science.gov (United States)

    Hadwen, B; Broder, G R; Morganti, D; Jacobs, A; Brown, C; Hector, J R; Kubota, Y; Morgan, H

    2012-09-21

    We describe a new device concept for digital microfluidics, based on an active matrix electrowetting on dielectric (AM-EWOD) device. A conventional EWOD device is limited by the number of electrical connections that can be made practically, which restricts the number and type of droplet operations. In an AM-EWOD, the patterned electrodes of a conventional EWOD device are replaced by a thin film transistor (TFT) array, as found in a liquid crystal display (LCD), facilitating independent control of each electrode. The arrays can have many thousand individually addressable electrodes, are fully reconfigurable and can be programmed to support multiple simultaneous operations. Each element is 210 μm × 210 μm in size and contains a circuit that measures the electrical impedance of the liquid above it. This is used to determine the presence and size of a droplet, a method that can improve assay reliability and accuracy. This sensor provides feedback, error detection and closed loop control of an assay sequence. We describe the design, fabrication and testing of a 64 × 64 format AM-EWOD device with impedance sensor functionality. A colorimetric assay is implemented on the device and used to measure glucose in human blood serum. Results are compared with the same assay performed on a microtitre plate.

  13. The development of a high speed solution for the evaluation of track structure Monte Carlo electron transport problems using field programmable gate arrays

    Science.gov (United States)

    Pasciak, Alexander Samuel

    There are two principal techniques for performing Monte Carlo electron transport computations. The first, and least common, is the full track-structure method. This method individually models all physical electron interactions including elastic scatter, electron impact ionization, radiative losses and excitations. However, because of the near infinite size of electron interaction cross-sections and highly anisotropic scattering behavior, this method requires an enormous amount of computation time. Alternatively, the Condensed History (CH) method for electron transport lumps the average effects of multiple energy loss and scattering events into one single pseudo-event, or step. Because of this approximation, the CH method can be orders of magnitude faster than the trackstructure method. While the CH method is reasonably accurate in many situations, it can be inaccurate for simulations involving microscopic site sizes such as those often found in radiation biology. For radiation biology and other microdosimetry applications, a computational device called a Field Programmable Gate Array (FPGA) is capable of executing track-structure Monte Carlo electron transport simulations as fast as, or faster than a standard computer performing transport via the CH method---and, it does so with the additional accuracy and level of detail provided by the track-structure method. In this dissertation, data from FPGA based track-structure electron transport computations are presented for five test cases, ranging in complexity from simple slab-style geometries to radiation biology applications involving electrons incident on endosteal bone surface cells. Even for the most complex test case presented, an FPGA is capable of evaluating track-structure electron transport problems more than 500 times faster than a standard computer can perform the same track-structure simulation, and with comparable accuracy.

  14. Single Event Analysis and Fault Injection Techniques Targeting Complex Designs Implemented in Xilinx-Virtex Family Field Programmable Gate Array (FPGA) Devices

    Science.gov (United States)

    Berg, Melanie D.; LaBel, Kenneth; Kim, Hak

    2014-01-01

    An informative session regarding SRAM FPGA basics. Presenting a framework for fault injection techniques applied to Xilinx Field Programmable Gate Arrays (FPGAs). Introduce an overlooked time component that illustrates fault injection is impractical for most real designs as a stand-alone characterization tool. Demonstrate procedures that benefit from fault injection error analysis.

  15. Development of a protection system for research reactor based in Field Programmable Gate Array - FPGA; Desenvolvimento de sistema de protecao para reator nuclear de pesquisa baseado em Field Programmable Gate Array - FPGA

    Energy Technology Data Exchange (ETDEWEB)

    Martins, Roque Hudson da Silva

    2016-07-01

    This study presents a implementation purpose of a protection system for research nuclear reactors by using a programed device FPGA (Field Programmable Gate Array). As well as logic protection method involved on an automatic shutdown (TRIP) of a reactor, that ensure the security on such systems. These new control and operation mechanics are developed to guarantee that the security limits of a power plant are not exceeded, these mechanics can work isolated or in groups to safe guard the security levels. For this implementation to be completed, there will be presented the main aspects and concepts referred to protection systems, mostly about research nuclear reactors, with some applications terms exposed. The system proposed at this paper was developed following the VHDL (Very High Speed Integrated Circuits) hardware describing language, and the Modelsim software from Altera Software to program the automatic turning off routines, and hypothetical simulations for such. The results show that for every software application for supporting nuclear reactors, like security devices, they have to meet the IEC 60880 criteria. This paper have great importance, seeing that nuclear reactor security systems, are a basic element for ensure the reactor security. (author)

  16. A digitizer based compact digital spectrometer for ion beam analysis using field programmable gate arrays and various energy algorithms

    Energy Technology Data Exchange (ETDEWEB)

    Jäger, Markus [Faculty of Mathematics and Computer Science, University of Leipzig, PF 100920, 04009 Leipzig (Germany); Reinert, Tilo [Department of Physics, University of North Texas, 1155 Union Circle, Denton, Texas 76203 (United States)

    2013-08-15

    We report on the implementation of a compact multi-detector fully digital spectrometer and data acquisition system at a nuclear microprobe for ion beam analysis and imaging. The spectrometer design allows for system scalability with no restriction on the number of detectors. It consists of four-channel high-speed digitizer modules for detector signal acquisition and one low-speed digital-to-analog converter (DAC) module with two DAC channels and additional general purpose inputs/outputs to control ion beam scanning and data acquisition. Each digitizer module of the spectrometer provides its own Field Programmable Gate Array (FPGA) as digital signal processing unit to analyze detector signals as well as to synchronize the ion beam position in hard real-time. With the customized FPGA designs for all modules, all calculation intensive tasks are executed inside the modules, which reduces significantly the data stream to and CPU load on the control computer. To achieve an optimal energy resolution for all detector/preamplifier pulse shape characteristics, a user-definable infinite impulse response filter with high throughput for energy determination was implemented. The new spectrometer has an online data analysis feature, a compact size, and is able to process any type of detector signals such as particle induced x-ray emission, Rutherford backscattering spectrometry, or scanning transmission ion microscopy.

  17. Design and implementation of a reconfigurable mixed-signal SoC based on field programmable analog arrays

    Science.gov (United States)

    Liu, Lintao; Gao, Yuhan; Deng, Jun

    2017-11-01

    This work presents a reconfigurable mixed-signal system-on-chip (SoC), which integrates switched-capacitor-based field programmable analog arrays (FPAA), analog-to-digital converter (ADC), digital-to-analog converter, digital down converter , digital up converter, 32-bit reduced instruction-set computer central processing unit (CPU) and other digital IPs on a single chip with 0.18 μm CMOS technology. The FPAA intellectual property could be reconfigured as different function circuits, such as gain amplifier, divider, sine generator, and so on. This single-chip integrated mixed-signal system is a complete modern signal processing system, occupying a die area of 7 × 8 mm 2 and consuming 719 mW with a clock frequency of 150 MHz for CPU and 200 MHz for ADC/DAC. This SoC chip can help customers to shorten design cycles, save board area, reduce the system power consumption and depress the system integration risk, which would afford a big prospect of application for wireless communication. Project supported by the National High Technology and Development Program of China (No. 2012AA012303).

  18. A Soft Computing Approach to Crack Detection and Impact Source Identification with Field-Programmable Gate Array Implementation

    Directory of Open Access Journals (Sweden)

    Arati M. Dixit

    2013-01-01

    Full Text Available The real-time nondestructive testing (NDT for crack detection and impact source identification (CDISI has attracted the researchers from diverse areas. This is apparent from the current work in the literature. CDISI has usually been performed by visual assessment of waveforms generated by a standard data acquisition system. In this paper we suggest an automation of CDISI for metal armor plates using a soft computing approach by developing a fuzzy inference system to effectively deal with this problem. It is also advantageous to develop a chip that can contribute towards real time CDISI. The objective of this paper is to report on efforts to develop an automated CDISI procedure and to formulate a technique such that the proposed method can be easily implemented on a chip. The CDISI fuzzy inference system is developed using MATLAB’s fuzzy logic toolbox. A VLSI circuit for CDISI is developed on basis of fuzzy logic model using Verilog, a hardware description language (HDL. The Xilinx ISE WebPACK9.1i is used for design, synthesis, implementation, and verification. The CDISI field-programmable gate array (FPGA implementation is done using Xilinx’s Spartan 3 FPGA. SynaptiCAD’s Verilog Simulators—VeriLogger PRO and ModelSim—are used as the software simulation and debug environment.

  19. A counting-weighted calibration method for a field-programmable-gate-array-based time-to-digital converter

    Science.gov (United States)

    Chen, Yuan-Ho

    2017-05-01

    In this work, we propose a counting-weighted calibration method for field-programmable-gate-array (FPGA)-based time-to-digital converter (TDC) to provide non-linearity calibration for use in positron emission tomography (PET) scanners. To deal with the non-linearity in FPGA, we developed a counting-weighted delay line (CWD) to count the delay time of the delay cells in the TDC in order to reduce the differential non-linearity (DNL) values based on code density counts. The performance of the proposed CWD-TDC with regard to linearity far exceeds that of TDC with a traditional tapped delay line (TDL) architecture, without the need for nonlinearity calibration. When implemented in a Xilinx Vertix-5 FPGA device, the proposed CWD-TDC achieved time resolution of 60 ps with integral non-linearity (INL) and DNL of [-0.54, 0.24] and [-0.66, 0.65] least-significant-bit (LSB), respectively. This is a clear indication of the suitability of the proposed FPGA-based CWD-TDC for use in PET scanners.

  20. A counting-weighted calibration method for a field-programmable-gate-array-based time-to-digital converter

    Energy Technology Data Exchange (ETDEWEB)

    Chen, Yuan-Ho, E-mail: chenyh@mail.cgu.edu.tw [Department of Electronic Engineering, Chang Gung University, Tao-Yuan 333, Taiwan (China); Department of Radiation Oncology, Chang Gung Memorial Hospital, Tao-Yuan 333, Taiwan (China); Center for Reliability Sciences and Technologies, Chang Gung University, Tao-Yuan 333, Taiwan (China)

    2017-05-11

    In this work, we propose a counting-weighted calibration method for field-programmable-gate-array (FPGA)-based time-to-digital converter (TDC) to provide non-linearity calibration for use in positron emission tomography (PET) scanners. To deal with the non-linearity in FPGA, we developed a counting-weighted delay line (CWD) to count the delay time of the delay cells in the TDC in order to reduce the differential non-linearity (DNL) values based on code density counts. The performance of the proposed CWD-TDC with regard to linearity far exceeds that of TDC with a traditional tapped delay line (TDL) architecture, without the need for nonlinearity calibration. When implemented in a Xilinx Vertix-5 FPGA device, the proposed CWD-TDC achieved time resolution of 60 ps with integral non-linearity (INL) and DNL of [−0.54, 0.24] and [−0.66, 0.65] least-significant-bit (LSB), respectively. This is a clear indication of the suitability of the proposed FPGA-based CWD-TDC for use in PET scanners.

  1. Theory and implementation of a very high throughput true random number generator in field programmable gate array.

    Science.gov (United States)

    Wang, Yonggang; Hui, Cong; Liu, Chong; Xu, Chao

    2016-04-01

    The contribution of this paper is proposing a new entropy extraction mechanism based on sampling phase jitter in ring oscillators to make a high throughput true random number generator in a field programmable gate array (FPGA) practical. Starting from experimental observation and analysis of the entropy source in FPGA, a multi-phase sampling method is exploited to harvest the clock jitter with a maximum entropy and fast sampling speed. This parametrized design is implemented in a Xilinx Artix-7 FPGA, where the carry chains in the FPGA are explored to realize the precise phase shifting. The generator circuit is simple and resource-saving, so that multiple generation channels can run in parallel to scale the output throughput for specific applications. The prototype integrates 64 circuit units in the FPGA to provide a total output throughput of 7.68 Gbps, which meets the requirement of current high-speed quantum key distribution systems. The randomness evaluation, as well as its robustness to ambient temperature, confirms that the new method in a purely digital fashion can provide high-speed high-quality random bit sequences for a variety of embedded applications.

  2. A simple digital control system with field-programmable gate array for stabilization of CO2 laser output

    Science.gov (United States)

    Huang, Renshuai; Guo, Xiaoyang; Meng, Qinglong; Zhang, Bin

    2017-04-01

    A simple digital control system was designed to stabilize CO2 laser based on digital signal processing with the Field-Programmable Gate Array (FPGA) controlling chip and Very-High-Speed Integrated Circuit Hardware Description Language program. In this system, the control parameters were easily determined by software real-time control, and the control circuit was also designed compactly. In addition, the theoretical analysis on the stabilization of CO2 laser output characteristics was presented based on the photoacoustic effect, and the corresponding experiments on the stabilization of CO2 laser output characteristics were further performed. The results show that the output power of CO2 laser is stabilized at the peak with a relative power stability of 2.71%. Furthermore, the frequency of CO2 laser 9P(36) line is stabilized at the center of the laser gain curve with a relative stability of (1.57 ± 0.37)×10-8. This system has a potential of further improvements by optimizing the algorithm and choosing higher-speed signal processor.

  3. An Intelligent Architecture Based on Field Programmable Gate Arrays Designed to Detect Moving Objects by Using Principal Component Analysis

    Science.gov (United States)

    Bravo, Ignacio; Mazo, Manuel; Lázaro, José L.; Gardel, Alfredo; Jiménez, Pedro; Pizarro, Daniel

    2010-01-01

    This paper presents a complete implementation of the Principal Component Analysis (PCA) algorithm in Field Programmable Gate Array (FPGA) devices applied to high rate background segmentation of images. The classical sequential execution of different parts of the PCA algorithm has been parallelized. This parallelization has led to the specific development and implementation in hardware of the different stages of PCA, such as computation of the correlation matrix, matrix diagonalization using the Jacobi method and subspace projections of images. On the application side, the paper presents a motion detection algorithm, also entirely implemented on the FPGA, and based on the developed PCA core. This consists of dynamically thresholding the differences between the input image and the one obtained by expressing the input image using the PCA linear subspace previously obtained as a background model. The proposal achieves a high ratio of processed images (up to 120 frames per second) and high quality segmentation results, with a completely embedded and reliable hardware architecture based on commercial CMOS sensors and FPGA devices. PMID:22163406

  4. An X-ray fluorescence microscopic analysis of the tissue surrounding the multi-channel cochlear implant electrode array.

    Science.gov (United States)

    Spiers, Kathryn; Cardamone, Tina; Furness, John B; Clark, Jonathan C M; Patrick, James F; Clark, Graeme M

    2016-05-01

    The aim of this study was to analyse the tissue surrounding the University of Melbourne's (UOMs) multi-channel cochlear implant electrode array and cochlear limited replacements, after long-term implantations. In particular, it aimed to identify the particulate material in the fibrous tissue capsule of the arrays implanted in 1978, 1983, and 1998, by using the Australian Synchrotron for X-ray fluorescence microscopy (XFM) to reveal the characteristic spectrum of metal, in particular platinum. This also helped to determine its format and chemical state. Tissue was retrieved following the recipient's death in 2007. Tissue was fixed and sections taken across the UOM and Cochlear Corporation (CI-22 and CI-24) electrode tracks. These were stained with Masson's trichrome. The Australian Synchrotron enabled XFM to accurately identify platinum from its characteristic fluorescence spectrum. There was a fibrous tissue capsule (about 100-µm thick) and small regions of calcification around the UOM and CI-22 arrays, but a thinner capsule (40-60-µm thick) around CI-24, and a greater degree of calcification. Dark particulate matter was observed within macrophages and especially in fibrous tissue in proximity to the UOM and CI-22 arrays. This was identified as platinum using X-ray fluorescence. There was also diffusion of platinum into the tissue surrounding the UOM and CI-22 electrodes and fine particles had penetrated the spiral ligament. The larger particulate matter in the tissue around the UOM and CI-22 arrays suggested that it had flaked off in the manufacturing of the UOM electrodes. The more diffuse spread of platinum in the tissue around the UOM and CI-22 electrodes was likely due to electrolysis, probably from charge imbalance with the bipolar pulses from the UOM implant. This did not occur with the Cochlear CI-24 device. Furthermore, the widespread fine particles of platinum could have also been due to corrosion, especially from the UOM electrodes.

  5. Single-Event Effect (SEE) Survey of Advanced Reconfigurable Field Programmable Gate Arrays: NASA Electronic Parts and Packaging (NEPP) Program Office of Safety and Mission Assurance

    Science.gov (United States)

    Allen, Gregory

    2011-01-01

    The NEPP Reconfigurable Field-Programmable Gate Array (FPGA) task has been charged to evaluate reconfigurable FPGA technologies for use in space. Under this task, the Xilinx single-event-immune, reconfigurable FPGA (SIRF) XQR5VFX130 device was evaluated for SEE. Additionally, the Altera Stratix-IV and SiliconBlue iCE65 were screened for single-event latchup (SEL).

  6. A field programmable gate array-based reconfigurable smart-sensor network for wireless monitoring of new generation computer numerically controlled machines.

    Science.gov (United States)

    Moreno-Tapia, Sandra Veronica; Vera-Salas, Luis Alberto; Osornio-Rios, Roque Alfredo; Dominguez-Gonzalez, Aurelio; Stiharu, Ion; Romero-Troncoso, Rene de Jesus

    2010-01-01

    Computer numerically controlled (CNC) machines have evolved to adapt to increasing technological and industrial requirements. To cover these needs, new generation machines have to perform monitoring strategies by incorporating multiple sensors. Since in most of applications the online Processing of the variables is essential, the use of smart sensors is necessary. The contribution of this work is the development of a wireless network platform of reconfigurable smart sensors for CNC machine applications complying with the measurement requirements of new generation CNC machines. Four different smart sensors are put under test in the network and their corresponding signal processing techniques are implemented in a Field Programmable Gate Array (FPGA)-based sensor node.

  7. A Field Programmable Gate Array-Based Reconfigurable Smart-Sensor Network for Wireless Monitoring of New Generation Computer Numerically Controlled Machines

    Science.gov (United States)

    Moreno-Tapia, Sandra Veronica; Vera-Salas, Luis Alberto; Osornio-Rios, Roque Alfredo; Dominguez-Gonzalez, Aurelio; Stiharu, Ion; de Jesus Romero-Troncoso, Rene

    2010-01-01

    Computer numerically controlled (CNC) machines have evolved to adapt to increasing technological and industrial requirements. To cover these needs, new generation machines have to perform monitoring strategies by incorporating multiple sensors. Since in most of applications the online Processing of the variables is essential, the use of smart sensors is necessary. The contribution of this work is the development of a wireless network platform of reconfigurable smart sensors for CNC machine applications complying with the measurement requirements of new generation CNC machines. Four different smart sensors are put under test in the network and their corresponding signal processing techniques are implemented in a Field Programmable Gate Array (FPGA)-based sensor node. PMID:22163602

  8. Fast contactless vibrating structure characterization using real time field programmable gate array-based digital signal processing: demonstrations with a passive wireless acoustic delay line probe and vision.

    Science.gov (United States)

    Goavec-Mérou, G; Chrétien, N; Friedt, J-M; Sandoz, P; Martin, G; Lenczner, M; Ballandras, S

    2014-01-01

    Vibrating mechanical structure characterization is demonstrated using contactless techniques best suited for mobile and rotating equipments. Fast measurement rates are achieved using Field Programmable Gate Array (FPGA) devices as real-time digital signal processors. Two kinds of algorithms are implemented on FPGA and experimentally validated in the case of the vibrating tuning fork. A first application concerns in-plane displacement detection by vision with sampling rates above 10 kHz, thus reaching frequency ranges above the audio range. A second demonstration concerns pulsed-RADAR cooperative target phase detection and is applied to radiofrequency acoustic transducers used as passive wireless strain gauges. In this case, the 250 ksamples/s refresh rate achieved is only limited by the acoustic sensor design but not by the detection bandwidth. These realizations illustrate the efficiency, interest, and potentialities of FPGA-based real-time digital signal processing for the contactless interrogation of passive embedded probes with high refresh rates.

  9. A Field Programmable Gate Array-Based Reconfigurable Smart-Sensor Network for Wireless Monitoring of New Generation Computer Numerically Controlled Machines

    Directory of Open Access Journals (Sweden)

    Ion Stiharu

    2010-08-01

    Full Text Available Computer numerically controlled (CNC machines have evolved to adapt to increasing technological and industrial requirements. To cover these needs, new generation machines have to perform monitoring strategies by incorporating multiple sensors. Since in most of applications the online Processing of the variables is essential, the use of smart sensors is necessary. The contribution of this work is the development of a wireless network platform of reconfigurable smart sensors for CNC machine applications complying with the measurement requirements of new generation CNC machines. Four different smart sensors are put under test in the network and their corresponding signal processing techniques are implemented in a Field Programmable Gate Array (FPGA-based sensor node.

  10. Implementation of sub-nanosecond time-to-digital convertor in field-programmable gate array: applications to time-of-flight analysis in muon radiography

    Science.gov (United States)

    Marteau, Jacques; de Bremond d'Ars, Jean; Gibert, Dominique; Jourde, Kevin; Gardien, Serge; Girerd, Claude; Ianigro, Jean-Christophe

    2014-03-01

    Time-of-flight (TOF) techniques are standard techniques in high energy physics to determine particles’ propagation directions. Since particle velocities are generally close to c, the speed of light, and detector typical dimensions at the metre level, the state-of-the-art TOF techniques should reach sub-nanosecond timing resolution. Among the various techniques already available, the recently developed ring oscillator time-to-digital converter (TDC) ones, implemented in low-cost programmable logic circuits like FPGA (field programmable gate array), feature a very interesting figure of merit since a very good timing performance may be achieved with limited processing resources. This issue is relevant for applications where unmanned sensors should have the lowest possible power consumption. Actually this paper describes in detail the application of this kind of TOF technique to muon tomography of geological bodies. Muon tomography aims at measuring density variations and absolute densities through the detection of atmospheric muon flux’s attenuation, due to the presence of matter. When the measured fluxes become very low, an identified source of noise comes from backwards propagating particles hitting the detector in a direction pointing to the geological body. The separation between through-going and backward-going particles on the basis of the TOF information is therefore a key parameter for the tomography analysis and subsequent forecasts. This paper describes a TDC implementation fulfilling the requirements of a TOF measurement applied to muon tomography.

  11. A VLSI field-programmable mixed-signal array to perform neural signal processing and neural modeling in a prosthetic system.

    Science.gov (United States)

    Bamford, Simeon A; Hogri, Roni; Giovannucci, Andrea; Taub, Aryeh H; Herreros, Ivan; Verschure, Paul F M J; Mintz, Matti; Del Giudice, Paolo

    2012-07-01

    A very-large-scale integration field-programmable mixed-signal array specialized for neural signal processing and neural modeling has been designed. This has been fabricated as a core on a chip prototype intended for use in an implantable closed-loop prosthetic system aimed at rehabilitation of the learning of a discrete motor response. The chosen experimental context is cerebellar classical conditioning of the eye-blink response. The programmable system is based on the intimate mixing of switched capacitor analog techniques with low speed digital computation; power saving innovations within this framework are presented. The utility of the system is demonstrated by the implementation of a motor classical conditioning model applied to eye-blink conditioning in real time with associated neural signal processing. Paired conditioned and unconditioned stimuli were repeatedly presented to an anesthetized rat and recordings were taken simultaneously from two precerebellar nuclei. These paired stimuli were detected in real time from this multichannel data. This resulted in the acquisition of a trigger for a well-timed conditioned eye-blink response, and repetition of unpaired trials constructed from the same data led to the extinction of the conditioned response trigger, compatible with natural cerebellar learning in awake animals.

  12. Using the Nucleic Acid Programmable Protein Array (NAPPA) for Identifying Protein-Protein Interactions. Protocol 1: Coexpression of Query Protein on NAPPA Slides.

    Science.gov (United States)

    Link, Andrew J; Labaer, Joshua

    2008-12-01

    INTRODUCTIONThe Nucleic Acid Programmable Protein Array (NAPPA) approach for producing protein microarrays uses cell-free extracts to transcribe and translate cDNAs encoding target proteins directly onto glass slides. Following array preparation, interactions with a protein of interest (query protein) are detected either by probing an expressed NAPPA slide with the purified query protein or by coexpressing the query protein on the NAPPA slide at the same time that the target proteins are expressed. This protocol describes the coexpression method, which involves adding the gene for the query protein to the cell-free protein expression mix. The amount of query protein that is transcribed and translated from the corresponding plasmid DNA depends on the amount of plasmid DNA used and the size of the protein of interest, among other factors. If too little query protein is expressed, there may be no detectable binding signal. Excessive amounts of protein expression may generate nonspecific background signals. Because the optimum amount of query plasmid varies with each query protein, it is essential to assess empirically the optimal amount of query protein DNA to add to a coexpression experiment.

  13. Microarray of programmable electrochemically active elements

    DEFF Research Database (Denmark)

    McCaskill, John; Maeke, Thomas; Straczek, Lukas

    Possible applications of the MICREAgents Dock, a two dimensional array of programmable electrochemically active elements, to Alife.......Possible applications of the MICREAgents Dock, a two dimensional array of programmable electrochemically active elements, to Alife....

  14. Visual analysis of ductility/brittleness of welding fracture points on charpy test specimens using graphical blocks on field programmable gate arrays

    Science.gov (United States)

    Tickle, Andrew J.; Camargo-Rodriguez, Anyela; Smith, Jeremy S.

    2008-09-01

    The charpy impact is a technique used to evaluate the toughness of an engineering material that determines the amount of energy absorbed by it during fracture. Initially, measurements were estimated manually and later replaced by a PC version. This study reports the development of the Field Programmable Gate Array (FPGA) portable version. The FPGA based version allows easy analysis of samples without the need of sending them to a lab for analysis. The process, presented here, as the original, is based on measuring the percent of crystal in the test sample after impact, to determine if the material is ductile or brittle. The FPGA version, adapted under the MATLAB Simulink environment, shows a graphical block representation of the charpy impact PC version. An important asset of the FPGA version is its portability, it has to be easily modified and downloaded onto a device to estimate the percent of brittle fracture of the broken Charpy surface. The beauty of the DSP Builder programme is that it allows the model to be compiled to various types of optimised code for any Altera FPGA device. To provide a firm basis for scientific comparison to the new FPGA system, images already analysed via the PC based Java system were also used for testing and comparison purposes. The FPGA system converts the image into an 8 bit grayscale image and analyses it in a 5x5 sampling window. This produces texture features that can be used in a comparison system, similar to the Support Vector Machine (SVM) used in the original. The output is a signal that states the material being tested is brittle or not via an output of '1' for brittle and a '0' for ductile. A detailed pixel by pixel analysis of the various output images is then investigated to state the percentage difference between the PC and FPGA based systems.

  15. Mitigation of cache memory using an embedded hard-core PPC440 processor in a Virtex-5 Field Programmable Gate Array.

    Energy Technology Data Exchange (ETDEWEB)

    Learn, Mark Walter

    2010-02-01

    Sandia National Laboratories is currently developing new processing and data communication architectures for use in future satellite payloads. These architectures will leverage the flexibility and performance of state-of-the-art static-random-access-memory-based Field Programmable Gate Arrays (FPGAs). One such FPGA is the radiation-hardened version of the Virtex-5 being developed by Xilinx. However, not all features of this FPGA are being radiation-hardened by design and could still be susceptible to on-orbit upsets. One such feature is the embedded hard-core PPC440 processor. Since this processor is implemented in the FPGA as a hard-core, traditional mitigation approaches such as Triple Modular Redundancy (TMR) are not available to improve the processor's on-orbit reliability. The goal of this work is to investigate techniques that can help mitigate the embedded hard-core PPC440 processor within the Virtex-5 FPGA other than TMR. Implementing various mitigation schemes reliably within the PPC440 offers a powerful reconfigurable computing resource to these node-based processing architectures. This document summarizes the work done on the cache mitigation scheme for the embedded hard-core PPC440 processor within the Virtex-5 FPGAs, and describes in detail the design of the cache mitigation scheme and the testing conducted at the radiation effects facility on the Texas A&M campus.

  16. Understanding radiation effects in SRAM-based field programmable gate arrays for implementing instrumentation and control systems of nuclear power plants

    Directory of Open Access Journals (Sweden)

    T.S. Nidhin

    2017-12-01

    Full Text Available Field programmable gate arrays (FPGAs are getting more attention in safety-related and safety-critical application development of nuclear power plant instrumentation and control systems. The high logic density and advancements in architectural features make static random access memory (SRAM-based FPGAs suitable for complex design implementations. Devices deployed in the nuclear environment face radiation particle strike that causes transient and permanent failures. The major reasons for failures are total ionization dose effects, displacement damage dose effects, and single event effects. Different from the case of space applications, soft errors are the major concern in terrestrial applications. In this article, a review of radiation effects on FPGAs is presented, especially soft errors in SRAM-based FPGAs. Single event upset (SEU shows a high probability of error in the dependable application development in FPGAs. This survey covers the main sources of radiation and its effects on FPGAs, with emphasis on SEUs as well as on the measurement of radiation upset sensitivity and irradiation experimental results at various facilities. This article also presents a comparison between the major SEU mitigation techniques in the configuration memory and user logics of SRAM-based FPGAs.

  17. A Field-Programmable Gate Array (FPGA) TDC for the Fermilab SeaQuest (E906) Experiment and Its Test with a Novel External Wave Union Launcher

    Science.gov (United States)

    Wang, Su-Yin; Wu, Jinyuan; Yao, Shi-Hong; Chang, Wen-Chen

    2014-12-01

    We developed a field-programmable gate array (FPGA) TDC module for the tracking detectors of the Fermilab SeaQuest (E906) experiment, including drift chambers, proportional tubes, and hodoscopes. This 64-channel TDC module had a 6U VMEbus form factor and was equipped with a low-power, radiation-hardened Microsemi ProASIC3 Flash-based FPGA. The design of the new FPGA firmware (Run2-TDC) aimed to reduce the data volume and data acquisition (DAQ) deadtime. The firmware digitized multiple input hits of both polarities while allowing users to turn on a multiple-hit elimination logic to remove after-pulses in the wire chambers and proportional tubes. A scaler was implemented in the firmware to allow for recording the number of hits in each channel. The TDC resolution was determined by an internal cell delay of 450 ps. A measurement precision of 200 ps was achieved. We used five kinds of tests to ensure the qualification of 93 TDCs in mass production. We utilized the external wave union launcher in our test to improve the TDC's measurement precision and also to illustrate how to construct the Wave Union TDC using an existing multi-hit TDC without modifying its firmware. Measurement precision was improved by a factor of about two (108 ps) based on the four-edge wave union. Better measurement precision (69 ps) was achieved by combining the approaches of Wave Union TDC and multiple-channel ganging.

  18. Multifocal nonlinear microscope with single element detector for multidepth imaging

    Science.gov (United States)

    Carriles, R.; Hoover, E. E.; Field, J. J.; Sheetz, K. E.; Squier, J. A.

    2011-08-01

    We present a laser scanning microscope capable of producing multiple focal volumes. These volumes can be displaced vertically, to acquire simultaneous images from multiple planes, or superimposed at the same depth but with different polarization states. We call this last implementation, differential multiphoton laser scanning microscopy (dMPLSM). To our knowledge, this constitutes the first report of a multifocal microscope with this capacity. The microscope is able to take images in different modalities, two-photon excited fluorescence, second, and third harmonic generation. In this work, we demonstrate several capabilities of our microscope: simultaneous acquisition of two and six images from two focal planes separated by several microns, and a pair of simultaneous images taken at the same focal plane but with two different polarizations. Some potential applications include following microorganism motion, studies of phase matching in microscopic environments, studies of blood flow, etc. The microscope is based on a pulsed ultrafast laser. The pulses are split, manipulated and recombined in an interlaced pattern in order to generate a sequence of pulses with different divergences, and possibly different polarizations. This pulse train is sent to the objective and focused at different depths. The signal is recorded using a photoncounting photomultiplier tube. Images from different foci are separated using time demultiplexing based on a low cost field programmable gate array. The use of a single element detector, instead of a multi-element (CCD camera), allows for imaging of scattering media. The use of photon counting leads to lower signal to noise ratio in the images.

  19. (Center of excellence: Microlaser microscope)

    Energy Technology Data Exchange (ETDEWEB)

    Webb, R.H.

    1992-01-01

    This Center-of-Excellence grant has two components: development of an imaging system based on microlaser arrays forms a central project among a group of laser diagnostic and therapeutic efforts primarily funded outside the grant. In these first 8 months we have set up the Microlaser Microscope using small microlaser arrays. We have emphasized the basics of microlaser handling and electronic addressing and the optics of the microscope. Details of electronics and optics given here will be used in the larger arrays which should be available soon. After a description of the central Microlaser Microscope project, we touch briefly on the other projects of the Center, which have been outstandingly fruitful this year. Publications are necessarily concerned with the smaller projects, since the Microlaser Microscope is in its early stages.

  20. Design verification enhancement of field programmable gate array-based safety-critical I&C system of nuclear power plant

    Energy Technology Data Exchange (ETDEWEB)

    Ahmed, Ibrahim [Department of Nuclear Engineering, Kyung Hee University, 1732 Deogyeong-daero, Giheung-gu, Yongin-si, Gyeonggi-do 17104 (Korea, Republic of); Jung, Jaecheon, E-mail: jcjung@kings.ac.kr [Department of Nuclear Power Plant Engineering, KEPCO International Nuclear Graduate School, 658-91 Haemaji-ro, Seosang-myeon, Ulju-gun, Ulsan 45014 (Korea, Republic of); Heo, Gyunyoung [Department of Nuclear Engineering, Kyung Hee University, 1732 Deogyeong-daero, Giheung-gu, Yongin-si, Gyeonggi-do 17104 (Korea, Republic of)

    2017-06-15

    Highlights: • An enhanced, systematic and integrated design verification approach is proposed for V&V of FPGA-based I&C system of NPP. • RPS bistable fixed setpoint trip algorithm is designed, analyzed, verified and discussed using the proposed approaches. • The application of integrated verification approach simultaneously verified the entire design modules. • The applicability of the proposed V&V facilitated the design verification processes. - Abstract: Safety-critical instrumentation and control (I&C) system in nuclear power plant (NPP) implemented on programmable logic controllers (PLCs) plays a vital role in safe operation of the plant. The challenges such as fast obsolescence, the vulnerability to cyber-attack, and other related issues of software systems have currently led to the consideration of field programmable gate arrays (FPGAs) as an alternative to PLCs because of their advantages and hardware related benefits. However, safety analysis for FPGA-based I&C systems, and verification and validation (V&V) assessments still remain important issues to be resolved, which are now become a global research point of interests. In this work, we proposed a systematic design and verification strategies from start to ready-to-use in form of model-based approaches for FPGA-based reactor protection system (RPS) that can lead to the enhancement of the design verification and validation processes. The proposed methodology stages are requirement analysis, enhanced functional flow block diagram (EFFBD) models, finite state machine with data path (FSMD) models, hardware description language (HDL) code development, and design verifications. The design verification stage includes unit test – Very high speed integrated circuit Hardware Description Language (VHDL) test and modified condition decision coverage (MC/DC) test, module test – MATLAB/Simulink Co-simulation test, and integration test – FPGA hardware test beds. To prove the adequacy of the proposed

  1. [Microscopic colitis].

    Science.gov (United States)

    Lukáš, Karel; Mandys, Václav

    2013-01-01

    Microscopic colitis is characterized by chronic or intermittent watery diarrhoea. Microscopic colitis is a common cause of chronic diarrhoea in predominantly older adults. The underlying mechanism in the pathogenesis of microscopic colitis remains unspecified. Microscopic colitis including colitis collagenous, lymphocytic, microscopic colitis with incomplete findings, minimal change colitis, eosinophilic colitis, Brainerd´s diarrhoea, graft-versus-host disease, mastocytic enterocolitis and postinfectious irritable bowel syndrome. Careful consideration of the clinical features and colonic mucosal biopsies usually lead to correct diagnosis. Treatments of microscopic colitis were based primarily on case reports and personal experience. Many medications have been proposed that either offer symptomatic relief (loperamide, cholestyramine) or had anti-inflammatory or immunosuppressive properties (aminosalicylates, steroids, adalimumab, azathioprine).

  2. Microwave Microscope

    Data.gov (United States)

    Federal Laboratory Consortium — FUNCTION: Makes ultra-high-resolution field measurements. The Microwave Microscope (MWM) has been used in support of several NRL experimental programs involving sea...

  3. A Spaceborne Synthetic Aperture Radar Partial Fixed-Point Imaging System Using a Field- Programmable Gate Array-Application-Specific Integrated Circuit Hybrid Heterogeneous Parallel Acceleration Technique.

    Science.gov (United States)

    Yang, Chen; Li, Bingyi; Chen, Liang; Wei, Chunpeng; Xie, Yizhuang; Chen, He; Yu, Wenyue

    2017-06-24

    With the development of satellite load technology and very large scale integrated (VLSI) circuit technology, onboard real-time synthetic aperture radar (SAR) imaging systems have become a solution for allowing rapid response to disasters. A key goal of the onboard SAR imaging system design is to achieve high real-time processing performance with severe size, weight, and power consumption constraints. In this paper, we analyse the computational burden of the commonly used chirp scaling (CS) SAR imaging algorithm. To reduce the system hardware cost, we propose a partial fixed-point processing scheme. The fast Fourier transform (FFT), which is the most computation-sensitive operation in the CS algorithm, is processed with fixed-point, while other operations are processed with single precision floating-point. With the proposed fixed-point processing error propagation model, the fixed-point processing word length is determined. The fidelity and accuracy relative to conventional ground-based software processors is verified by evaluating both the point target imaging quality and the actual scene imaging quality. As a proof of concept, a field- programmable gate array-application-specific integrated circuit (FPGA-ASIC) hybrid heterogeneous parallel accelerating architecture is designed and realized. The customized fixed-point FFT is implemented using the 130 nm complementary metal oxide semiconductor (CMOS) technology as a co-processor of the Xilinx xc6vlx760t FPGA. A single processing board requires 12 s and consumes 21 W to focus a 50-km swath width, 5-m resolution stripmap SAR raw data with a granularity of 16,384 × 16,384.

  4. Solid state optical microscope

    Science.gov (United States)

    Young, Ian T.

    1983-01-01

    A solid state optical microscope wherein wide-field and high-resolution images of an object are produced at a rapid rate by utilizing conventional optics with a charge-coupled photodiode array. A galvanometer scanning mirror, for scanning in one of two orthogonal directions is provided, while the charge-coupled photodiode array scans in the other orthogonal direction. Illumination light from the object is incident upon the photodiodes, creating packets of electrons (signals) which are representative of the illuminated object. The signals are then processed, stored in a memory, and finally displayed as a video signal.

  5. Martian Microscope

    Science.gov (United States)

    2004-01-01

    The microscopic imager (circular device in center) is in clear view above the surface at Meridiani Planum, Mars, in this approximate true-color image taken by the panoramic camera on the Mars Exploration Rover Opportunity. The image was taken on the 9th sol of the rover's journey. The microscopic imager is located on the rover's instrument deployment device, or arm. The arrow is pointing to the lens of the instrument. Note the dust cover, which flips out to the left of the lens, is open. This approximated color image was created using the camera's violet and infrared filters as blue and red.

  6. Adaptation of a quantitative programme for the X-ray analysis of solubilized tissue as microdroplets in the transmission electron microscope: application to the moult cycle of the shrimp Crangon crangon (L).

    Science.gov (United States)

    Nott, J A; Mavin, L J

    1986-09-01

    A quantitative programme for X-ray microanalysis is used in a non-standard manner on solubilized tissue which has been spiked with cobalt and sprayed as microdroplets on electron microscope grids. During the procedure the count time and the concentration of cobalt is related to the peak integral and, from the relative efficiencies, the concentrations of other elements are computed from the peak integrals. Absorption is taken into account but the X-ray background is not used to estimate the total mass and the beam current is not measured. The method is applied to the hepatopancreas and blood from individual shrimps, Crangon crangon, to give the concentrations of sodium, magnesium, silicon, phosphorus, sulphur, potassium and calcium at different stages of the moult cycle. In the hepatopancreas the absolute and relative quantities of phosphorus, sulphur and other elements change in phase with the moult cycle. This situation must be linked with fluctuations in levels of metabolic activity and may affect the metal-binding capacity of the tissue which is known to fluctuate. The hepatopancreas accumulates lipid and phosphorus during the intermoult period, but the level of phospholipid phosphorus remains as a constant proportion of the tissue wet weight. The gland does not store calcium for hardening the new exoskeleton after ecdysis. Magnesium is a more important and variable component and could be linked with metabolic activity. The blood composition remains more stable. However, sulphur concentration is high and variable and this may, to some extent, reflect changes in the concentration of taurine. The concentration of copper increases towards the end of the moult cycle and decreases during moulting; opposite changes occur in the hepatopancreas.

  7. Microscopic colitis

    DEFF Research Database (Denmark)

    Münch, A; Aust, D; Bohr, Jakob

    2012-01-01

    Microscopic colitis (MC) is an inflammatory bowel disease presenting with chronic, non-bloody watery diarrhoea and few or no endoscopic abnormalities. The histological examination reveals mainly two subtypes of MC, lymphocytic or collagenous colitis. Despite the fact that the incidence in MC has...

  8. Microscopic Polyangiitis

    Science.gov (United States)

    ... share a variety of features but possess sufficient differences as to justify separate classifications. Who gets Microscopic Polyangiitis? A typical patient MPA can affect individuals from all ethnic backgrounds and any age group. In the United States, the typical MPA patient ...

  9. Microscopic colitis.

    Science.gov (United States)

    Ianiro, Gianluca; Cammarota, Giovanni; Valerio, Luca; Annicchiarico, Brigida Eleonora; Milani, Alessandro; Siciliano, Massimo; Gasbarrini, Antonio

    2012-11-21

    Microscopic colitis may be defined as a clinical syndrome, of unknown etiology, consisting of chronic watery diarrhea, with no alterations in the large bowel at the endoscopic and radiologic evaluation. Therefore, a definitive diagnosis is only possible by histological analysis. The epidemiological impact of this disease has become increasingly clear in the last years, with most data coming from Western countries. Microscopic colitis includes two histological subtypes [collagenous colitis (CC) and lymphocytic colitis (LC)] with no differences in clinical presentation and management. Collagenous colitis is characterized by a thickening of the subepithelial collagen layer that is absent in LC. The main feature of LC is an increase of the density of intra-epithelial lymphocytes in the surface epithelium. A number of pathogenetic theories have been proposed over the years, involving the role of luminal agents, autoimmunity, eosinophils, genetics (human leukocyte antigen), biliary acids, infections, alterations of pericryptal fibroblasts, and drug intake; drugs like ticlopidine, carbamazepine or ranitidine are especially associated with the development of LC, while CC is more frequently linked to cimetidine, non-steroidal antiinflammatory drugs and lansoprazole. Microscopic colitis typically presents as chronic or intermittent watery diarrhea, that may be accompanied by symptoms such as abdominal pain, weight loss and incontinence. Recent evidence has added new pharmacological options for the treatment of microscopic colitis: the role of steroidal therapy, especially oral budesonide, has gained relevance, as well as immunosuppressive agents such as azathioprine and 6-mercaptopurine. The use of anti-tumor necrosis factor-α agents, infliximab and adalimumab, constitutes a new, interesting tool for the treatment of microscopic colitis, but larger, adequately designed studies are needed to confirm existing data.

  10. Multibeam scanning electron microscope : Experimental results

    NARCIS (Netherlands)

    Mohammadi-Gheidari, A.; Hagen, C.W.; Kruit, P.

    2010-01-01

    The authors present the first results obtained with their multibeam scanning electron microscope. For the first time, they were able to image 196 (array of 14×14) focused beams of a multielectron beam source on a specimen using single beam scanning electron microscope (SEM) optics. The system

  11. Programmable architecture for quantum computing

    NARCIS (Netherlands)

    Chen, J.; Wang, L.; Charbon, E.; Wang, B.

    2013-01-01

    A programmable architecture called “quantum FPGA (field-programmable gate array)” (QFPGA) is presented for quantum computing, which is a hybrid model combining the advantages of the qubus system and the measurement-based quantum computation. There are two kinds of buses in QFPGA, the local bus and

  12. Laser Scanning Fluorescence Microscope

    Science.gov (United States)

    Hansen, Eric W.; Zelten, J. Peter; Wiseman, Benjamin A.

    1988-06-01

    We report on the development of a laser scanning fluorescence microscope possessing several features which facilitate its application to biological and biophysical analyses in living cells. It is built around a standard inverted microscope stand, enabling the use of standard optics, micromanipulation apparatus, and conventional (including video) microscopy in conjunction with laser scanning. The beam is scanned across the specimen by a pair of galvanometer-mounted mirrors, driven by a programmable controller which can operate in three modes: full raster scan, region of interest, and random-access. A full 512x512 pixel image can be acquired in one second. In region of interest mode, several subareas of the field can be selected for more rapid or detailed analysis. For those cases where the time scale of the observed phenomenon precludes full-field imaging, or where a full-field image is unnecessary, the random access mode enables an arbitrary pattern of isolated points to be selected and rapidly sequenced through. Via a graphical user interface implemented on the system's host computer, a user will be able to take a scout image either with video or a full-field laser scan, select regions or points on the scout image with a mouse, and set up experimental parameters such as detector integration times with a window-style menu. The instrument is designed to be a flexible testbed for investigating new techniques, without compromising its utility as a tool for biological research.

  13. Electronic Switch Arrays for Managing Microbattery Arrays

    Science.gov (United States)

    Mojarradi, Mohammad; Alahmad, Mahmoud; Sukumar, Vinesh; Zghoul, Fadi; Buck, Kevin; Hess, Herbert; Li, Harry; Cox, David

    2008-01-01

    Integrated circuits have been invented for managing the charging and discharging of such advanced miniature energy-storage devices as planar arrays of microscopic energy-storage elements [typically, microscopic electrochemical cells (microbatteries) or microcapacitors]. The architecture of these circuits enables implementation of the following energy-management options: dynamic configuration of the elements of an array into a series or parallel combination of banks (subarrarys), each array comprising a series of parallel combination of elements; direct addressing of individual banks for charging/or discharging; and, disconnection of defective elements and corresponding reconfiguration of the rest of the array to utilize the remaining functional elements to obtain the desited voltage and current performance. An integrated circuit according to the invention consists partly of a planar array of field-effect transistors that function as switches for routing electric power among the energy-storage elements, the power source, and the load. To connect the energy-storage elements to the power source for charging, a specific subset of switches is closed; to connect the energy-storage elements to the load for discharging, a different specific set of switches is closed. Also included in the integrated circuit is circuitry for monitoring and controlling charging and discharging. The control and monitoring circuitry, the switching transistors, and interconnecting metal lines are laid out on the integrated-circuit chip in a pattern that registers with the array of energy-storage elements. There is a design option to either (1) fabricate the energy-storage elements in the corresponding locations on, and as an integral part of, this integrated circuit; or (2) following a flip-chip approach, fabricate the array of energy-storage elements on a separate integrated-circuit chip and then align and bond the two chips together.

  14. Protein Functionalized Nanodiamond Arrays

    Directory of Open Access Journals (Sweden)

    Liu YL

    2010-01-01

    Full Text Available Abstract Various nanoscale elements are currently being explored for bio-applications, such as in bio-images, bio-detection, and bio-sensors. Among them, nanodiamonds possess remarkable features such as low bio-cytotoxicity, good optical property in fluorescent and Raman spectra, and good photostability for bio-applications. In this work, we devise techniques to position functionalized nanodiamonds on self-assembled monolayer (SAMs arrays adsorbed on silicon and ITO substrates surface using electron beam lithography techniques. The nanodiamond arrays were functionalized with lysozyme to target a certain biomolecule or protein specifically. The optical properties of the nanodiamond-protein complex arrays were characterized by a high throughput confocal microscope. The synthesized nanodiamond-lysozyme complex arrays were found to still retain their functionality in interacting with E. coli.

  15. Transmission positron microscopes

    Energy Technology Data Exchange (ETDEWEB)

    Doyama, Masao [Teikyo University of Science and Technology, Uenohara, Yamanashi 409-0193 (Japan)]. E-mail: doyama@ntu.ac.jp; Kogure, Yoshiaki [Teikyo University of Science and Technology, Uenohara, Yamanashi 409-0193 (Japan); Inoue, Miyoshi [Teikyo University of Science and Technology, Uenohara, Yamanashi 409-0193 (Japan); Kurihara, Toshikazu [Institute of Materials Structure Science (IMSS), High Energy Accelerator, Research Organization (KEK), Ohno 1-1, Tsukuba, Ibaraki 305-0801 (Japan); Yoshiie, Toshimasa [Reactor Research Institute, Kyoto University, Noda, Kumatori, Osaka 590-0451 (Japan); Oshima, Ryuichiro [Research Institute for Advanced Science and Technology, Osaka Prefecture University (Japan); Matsuya, Miyuki [Electron Optics Laboratory (JEOL) Ltd., Musashino 3-1-2, Akishima 196-0021 (Japan)

    2006-02-28

    Immediate and near-future plans for transmission positron microscopes being built at KEK, Tsukuba, Japan, are described. The characteristic feature of this project is remolding a commercial electron microscope to a positron microscope. A point source of electrons kept at a negative high voltage is changed to a point source of positrons kept at a high positive voltage. Positional resolution of transmission microscopes should be theoretically the same as electron microscopes. Positron microscopes utilizing trapping of positrons have always positional ambiguity due to the diffusion of positrons.

  16. The Scanning Optical Microscope.

    Science.gov (United States)

    Sheppard, C. J. R.

    1978-01-01

    Describes the principle of the scanning optical microscope and explains its advantages over the conventional microscope in the improvement of resolution and contrast, as well as the possibility of producing a picture from optical harmonies generated within the specimen.

  17. Digital Fingerprinting of Field Programmable Gate Arrays

    Science.gov (United States)

    2008-03-01

    feature size necessitates a redesign and new fabrication run. As a result, the FPGA has become popular in the commercial market, and by extension in DoD...in a pseudo-computer language, VHDL or Verilog , and downloading it to the FPGA to run. Updates are as simple as adding a few new lines of code, running...television operating by 1’s and 0’s. The truth is that the world is actually analog and that the devices considered digital are, in reality, dealing

  18. Graphics algorithms on field programmable function arrays

    NARCIS (Netherlands)

    Smit, Jaap; Bosma, Marco

    1996-01-01

    The amount of energy consumed in basic CMOS building blocks, like external RAM, external bus-structures, multipliers, local (cache) memory and on chip bus-structures, is analyzed thoroughly to find ways for substantial improvement of the power consumption of high speed graphics algorithms: A Field

  19. Microarray of programmable electrochemically active elements

    DEFF Research Database (Denmark)

    S. McCaskill, John; Maeke, Thomas; Straczek, Lukas

    2016-01-01

    This paper describes possible applications of a two dimensional array of programmable electrochemically active elements to Alife. The array has been developed as part of the MICREA-gents project, and after several design phases, is now a mature enough device for general use beyond the project. He...

  20. [Center of excellence: Microlaser microscope]. Annual progress report

    Energy Technology Data Exchange (ETDEWEB)

    Webb, R.H.

    1992-05-01

    This Center-of-Excellence grant has two components: development of an imaging system based on microlaser arrays forms a central project among a group of laser diagnostic and therapeutic efforts primarily funded outside the grant. In these first 8 months we have set up the Microlaser Microscope using small microlaser arrays. We have emphasized the basics of microlaser handling and electronic addressing and the optics of the microscope. Details of electronics and optics given here will be used in the larger arrays which should be available soon. After a description of the central Microlaser Microscope project, we touch briefly on the other projects of the Center, which have been outstandingly fruitful this year. Publications are necessarily concerned with the smaller projects, since the Microlaser Microscope is in its early stages.

  1. Cryogenic immersion microscope

    Science.gov (United States)

    Le Gros, Mark; Larabell, Carolyn A.

    2010-12-14

    A cryogenic immersion microscope whose objective lens is at least partially in contact with a liquid reservoir of a cryogenic liquid, in which reservoir a sample of interest is immersed is disclosed. When the cryogenic liquid has an index of refraction that reduces refraction at interfaces between the lens and the sample, overall resolution and image quality are improved. A combination of an immersion microscope and x-ray microscope, suitable for imaging at cryogenic temperatures is also disclosed.

  2. Analytical Electron Microscope

    Data.gov (United States)

    Federal Laboratory Consortium — The Titan 80-300 is a transmission electron microscope (TEM) equipped with spectroscopic detectors to allow chemical, elemental, and other analytical measurements to...

  3. Mailing microscope slides

    Science.gov (United States)

    Many insects feed agriculturally important crops, trees, and ornamental plants and cause millions of dollars of damage annually. Identification for some of these require the preparation of a microscope slide for examination. There are times when a microscope slide may need to be sent away to a speci...

  4. Atomic Force Microscope for Imaging and Spectroscopy

    Science.gov (United States)

    Pike, W. T.; Hecht, M. H.; Anderson, M. S.; Akiyama, T.; Gautsch, S.; deRooij, N. F.; Staufer, U.; Niedermann, Ph.; Howald, L.; Mueller, D.

    2000-01-01

    We have developed, built, and tested an atomic force microscope (AFM) for extraterrestrial applications incorporating a micromachined tip array to allow for probe replacement. It is part of a microscopy station originally intended for NASA's 2001 Mars lander to identify the size, distribution, and shape of Martian dust and soil particles. As well as imaging topographically down to nanometer resolution, this instrument can be used to reveal chemical information and perform infrared and Raman spectroscopy at unprecedented resolution.

  5. Programmable Surfaces

    Science.gov (United States)

    2014-03-30

    Griffith, IEEE Transactions on Robotics (27:4), pp. 718-729 (2011)], electropermanent actuators for high torque at low RPM with static holding...active cylinders in an engine or fibers in a muscle . Fan array number and orientation dependence The next question addressed was the aerodynamic

  6. Technology Programme

    Energy Technology Data Exchange (ETDEWEB)

    Batistoni, Paola; De Marco, Francesco; Pieroni, Leonardo (ed.)

    2005-07-01

    The technology activities carried out by the Euratom-ENEA Association in the framework of the European Fusion Development Agreement concern the Next Step (International Thermonuclear Experimental Reactor - ITER), the Long-Term Programme (breeder blanket, materials, International Fusion Materials Irradiation Facility - IFMIF), Power Plant Conceptual Studies and Socio-Economic Studies. The Underlying Technology Programme was set up to complement the fusion activities as well to develop technologies with a wider range of interest. The Technology Programme mainly involves staff from the Frascati laboratories of the Fusion Technical and Scientific Unit and from the Brasimone laboratories of the Advanced Physics Technologies Unit. Other ENEA units also provide valuable contributions to the programme. ENEA is heavily engaged in component development/testing and in design and safety activities for the European Fusion Technology Programme. Although the work documented in the following covers a large range of topics that differ considerably because they concern the development of extremely complex systems, the high level of integration and coordination ensures the capability to cover the fusion system as a whole. In 2004 the most significant testing activities concerned the ITER primary beryllium-coated first wall. In the field of high-heat-flux components, an important achievement was the qualification of the process for depositing a copper liner on carbon fibre composite (CFC) hollow tiles. This new process, pre-brazed casting (PBC), allows the hot radial pressing (HRP) joining procedure to be used also for CFC-based armour monoblock divertor components. The PBC and HRP processes are candidates for the construction of the ITER divertor. In the materials field an important milestone was the commissioning of a new facility for chemical vapour infiltration/deposition, used for optimising silicon carbide composite (SiCf/SiC) components. Eight patents were deposited during 2004

  7. [Microscopic colitis: update 2014].

    Science.gov (United States)

    Burgmann, Konstantin; Fraga, Montserrat; Schoepfer, Alain M; Yun, Pu

    2014-09-03

    Microscopic colitis, which includes lymphocytic colitis and collagenous colitis, represents a frequent cause of chronic watery diarrhea especially in the elderly population. Several medications, such as nonsteroidal antiinflammatory drugs, proton pump inhibitors or antidepressants, as well as cigarette smoking have been recognized as risk factors for microscopic colitis. The diagnosis of microscopic colitis is based on a macroscopically normal ileo-colonoscopy and several biopsies from the entire colon, which demonstrate the pathognomonic histopathologic findings. Therapy is mainly based on the use of budesonide. Other medications, such as mesalazine, cholestyramine and bismuth, have been evaluated as well but the evidence is less solid.

  8. Scanning Auger Electron Microscope

    Data.gov (United States)

    Federal Laboratory Consortium — A JEOL model 7830F field emission source, scanning Auger microscope.Specifications / Capabilities:Ultra-high vacuum (UHV), electron gun range from 0.1 kV to 25 kV,...

  9. Microscopic colitis: a review.

    Science.gov (United States)

    Farrukh, A; Mayberry, J F

    2014-12-01

    In recent years, microscopic colitis has been increasingly diagnosed. This review was carried out to evaluate demographic factors for microscopic colitis and to perform a systematic assessment of available treatment options. Relevant publications up to December 2013 were identified following searches of PubMed and Google Scholar using the key words 'microscopic colitis', 'collagenous colitis' and 'lymphocytic colitis'. Two-hundred and forty-eight articles were identified. The term microscopic colitis includes lymphocytic colitis and collagenous colitis. Both have common clinical symptoms but are well defined histopathologically. The clinical course is usually benign, but serious complications, including death, may occur. A peak incidence from 60 to 70 years of age with a female preponderance is observed. Although most cases are idiopathic, associations with autoimmune disorders, such as coeliac disease and hypothyroidism, as well as with exposure to nonsteroidal anti-inflammatory drugs and proton-pump inhibitors, have been observed. The incidence and prevalence of microscopic colitis is rising and good-quality epidemiological research is needed. Treatment is currently largely based on anecdotal evidence and on results from limited clinical trials of budesonide. Long-term follow-up of these patients is not well established. The review synthesizes work on the definition of microscopic colitis and the relationship between collagenous and lymphocytic colitis. It reviews the international epidemiology and work on aetiology. In addition, it critically considers the efficacy of a range of treatments. Colorectal Disease © 2014 The Association of Coloproctology of Great Britain and Ireland.

  10. Miniaturized integration of a fluorescence microscope

    Science.gov (United States)

    Ghosh, Kunal K.; Burns, Laurie D.; Cocker, Eric D.; Nimmerjahn, Axel; Ziv, Yaniv; Gamal, Abbas El; Schnitzer, Mark J.

    2013-01-01

    The light microscope is traditionally an instrument of substantial size and expense. Its miniaturized integration would enable many new applications based on mass-producible, tiny microscopes. Key prospective usages include brain imaging in behaving animals towards relating cellular dynamics to animal behavior. Here we introduce a miniature (1.9 g) integrated fluorescence microscope made from mass-producible parts, including semiconductor light source and sensor. This device enables high-speed cellular-level imaging across ∼0.5 mm2 areas in active mice. This capability allowed concurrent tracking of Ca2+ spiking in >200 Purkinje neurons across nine cerebellar microzones. During mouse locomotion, individual microzones exhibited large-scale, synchronized Ca2+ spiking. This is a mesoscopic neural dynamic missed by prior techniques for studying the brain at other length scales. Overall, the integrated microscope is a potentially transformative technology that permits distribution to many animals and enables diverse usages, such as portable diagnostics or microscope arrays for large-scale screens. PMID:21909102

  11. Miniaturized integration of a fluorescence microscope.

    Science.gov (United States)

    Ghosh, Kunal K; Burns, Laurie D; Cocker, Eric D; Nimmerjahn, Axel; Ziv, Yaniv; Gamal, Abbas El; Schnitzer, Mark J

    2011-09-11

    The light microscope is traditionally an instrument of substantial size and expense. Its miniaturized integration would enable many new applications based on mass-producible, tiny microscopes. Key prospective usages include brain imaging in behaving animals for relating cellular dynamics to animal behavior. Here we introduce a miniature (1.9 g) integrated fluorescence microscope made from mass-producible parts, including a semiconductor light source and sensor. This device enables high-speed cellular imaging across ∼0.5 mm2 areas in active mice. This capability allowed concurrent tracking of Ca2+ spiking in >200 Purkinje neurons across nine cerebellar microzones. During mouse locomotion, individual microzones exhibited large-scale, synchronized Ca2+ spiking. This is a mesoscopic neural dynamic missed by prior techniques for studying the brain at other length scales. Overall, the integrated microscope is a potentially transformative technology that permits distribution to many animals and enables diverse usages, such as portable diagnostics or microscope arrays for large-scale screens.

  12. ISOLDE PROGRAMME

    CERN Document Server

    Fedosseev, V; Herfurth, F; Scheidenberger, C; Geppert, C; Gorges, C; Ratajczyk, T; Wiederhold, J C; Vogel, S; Munch, M K; Nieminen, P; Pakarinen, J J A; Lecesne, N; Bouzomita, H; Grinyer, J; Marques moreno, F M; Parlog, M; Blank, B A; Pedroza, J; Ghetta, V; Lozeva, R; Guillemaud mueller, D S; Cottereau, E; Cheikh mhamed, M; Tusseau nenez, S; Tungate, G; Walker, P M; Smith, A G; Fitzpatrick, C; Dominik, W M; Karny, M; Ciemny, A A; Nyman, G H; Thies, R M A; Lindberg, S K G; Langouche, G F; Mayet, P; Ory, G T; Kesteloot, N J K; Papuga, J; Dehairs, M H R; Callens, M; Araujo escalona, V I; Stamati, M; Boudreau, M; Domnanich, K A; Richter, D; Lutter, R J; Javaji, A; Engel, R Y; Wiehr, S; Martinez perez, T; Nacher gonzalez, E; Jungclaus, A; Ribeiro jimenez, G; Marroquin alonso, I; Cal gonzalez, J; Paziy, V; Salsac, M; Murphy, C; Podolyak, Z F; Bajoga, A D; Butler, P; Pritchard, A; Colosimo, S J; Steer, A N; Fox, S P; Wadsworth, B A; Truesdale, V L; Al monthery, M; Bracco, A; Guttormsen, M S; Badea, M N; Calinescu, S; Ujeniuc, S; Cederkall, J A; Zemlyanoy, S; Donets, E D; Golovkov, M; Vranicar, A; Harrichunder, S; Ncube, M; Strisovska, J; Wolf, E; Gerten, R F; Lehnert, J; Gladnishki, K A; Rainovski, G I; Pospisil, S; Datta pramanik, U; Benzoni, G; Fedorov, D; Molkanov, P; Maier, F M; Bonanni, A; Pfeiffer, B; Griesel, T; Wehner, L W; Mikkelsen, M; Lenzi, S M; Smith, J F; Kelly, C M; Acosta sanchez, L A; Chavez lomeli, E R; De melo bandeira tavares, P M; Vieira, J M; Martins da silva, M A; Lima lopes, A M; Mader, J; Kessler, P; Laurent, B G; Schweikhard, L C; Marx, G H; Kulczycka, E; Komorowska, M; Da silva, M F; Goncalves marques, C P; Baptista peres, M A; Welander, J E; Reiter, P; Miller, C; Martin sanchez-cano, D; Wiens, A; Blazhev, A A; Braun, N; Cappellazzo, M V; Birkenbach, B; Gerst, R; Dannhoff, M F; Sithole, M J; Bilgier, B; Nardelli, S; Araujo mendes, C M; Agramunt ros, J; Valencia marin, E; Pantea, E; Hessberger, F P; Leduc, A J; Mitsuoka, S; Carbonari, A W; Buchegger, F J; Garzon camacho, A; Dapo, H; Papka, P; Stachura, M K; Stora, T; Marsh, B A; Thiboud, J A; Heylen, H; Antalic, S; Stahl, C; Bauer, C; Thurauf, M; Maass, B; Sturm, S; Boehm, C; Wolf, N R; Ways, M; Steinsberger, T P; Riisager, K; Ruotsalainen, P A; Bastin, B; Duval, F T; Penessot, G; Flechard, X D; Desrues, P; Giovinazzo, J; Kurtukian nieto, T; Ascher, P E L; Roccia, S; Matea, I; Croizet, H A G; Bonnin, C M; Morfouace, P; Smith, A J; Guin, R; Banerjee, D; Gunnlaugsson, H P; Ohtsubo, T; Zhukov, M V; Tengborn, E A; Welker, A; Giannopoulos, E; Dessagne, P; Juscamaita vivanco, Y; De rydt, M A E; Da costa pereira, L M; Vermaelen, P; Monten, R; Wursten, E J; De coster, A; Jin, H; Hustings, J; Yu, H; Kruecken, R; Nowak, A K; Jankowski, M; Cano ott, D; Murphy, A S J; Shand, C M; Jones, G D; Herzberg, R; Ikin, P; Revill, J P; Everett, C; Napoli, D R; Scarel, G; Larsen, A; Tornyi, T G; Pascu, S G; Stroe, L; Toma, S; Jansson, K; Dronjak fahlander, M; Krupko, S; Hurst, A M; Veskovic, M; Nikolov, J; Masenda, H; Sibanda, W N; Rocchini, M; Klimo, J; Deicher, M; Wichert, T; Kronenberg, J; Helmke, A; Meliani, Z; Ivanov, V S; Keatings, J M; Kuti, I; Halasz, Z; Henry, M O; Bras de sequeira amaral, V; Espirito santo, F; Da silva, D J; Rosendahl, S; Vianden, R J; Speidel, K; Agarwal, I; Faul, T; Kownacki, J M; Martins correia, J G; Lorenz, K; Costa miranda, S M; Granadeiro costa, A R; Zyabkin, D; Kotthaus, T; Pfeiffer, M; Gironi, L; Cakirli, R B; Jensen, A; Romstedt, F; Constantino silva furtado, I; Heredia cardona, J A; Jordan martin, M D; Montaner piza, A; Zacate, M O; Plewinski, F; Mesli, A; Akakpo, E H; Pichard, A; Hergemoller, F; Neu, W; Fallis starhunter, J P; Voulot, D; Mrazek, J; Ugryumov, V; Savreux, R P; Kojouharov, I M; Stegmann, R; Kern, R O; Papst, O; Fitting, J; Lauer, M; Kirsebom, O S; Jensen, K L; Jokinen, A; Rahkila, P J; Hager, U D K; Konki, J P; Dubois, M; Orr, N A; Fabian, X; Huikari, J E; Goigoux, T; Magron, C; Zakari, A A; Maietta, M; Bachelet, C E M; Roussiere, B; Li, R; Canavan, R L; Lorfing, C; Foster, R M; Gislason, H P; Shayestehaminzadeh, S; Qi, B; Mukai, M; Watanabe, Y; Willmann, L; Kurcewicz, W; Wimmer, K; Meisel, Z P; Dorvaux, O; Nowacki, F; Koudriavtsev, I; Lievens, P; Delaure, B J P; Neyens, G; Darby, I G; Descamps, B O; Velten, P; Ceruti, S; Bunka, M; Vermeulen, C; Umbricht, C A; De boer, J; Podadera aliseda, I; Alcorta moreno, M; Pesudo fortes, V; Zielinska, M; Korten, W; Wang, C H; Lotay, G J; Mason, P; Rice, S J; Regan, P H; Willenegger, L M; Andreev, A; Yavuzkanat, N; Hass, M; Kumar, V; Valiente dobon, J J; Crespo campo, L; Zamfir, N - V; Deleanu, D; Jeppesen, H B; Wu, C; Pain, S D; Stracener, D W; Szilner, S; Colovic, P; Matousek, V; Venhart, M; Birova, M; Li, X; Stuchbery, A E; Lellep, G M; Chakraborty, S; Leoni, S; Chupp, T; Yilmaz, C; Severin, G; Garcia ramos, J E; Hadinia, B; Mc glynn, E; Monteiro de sena silvares de carvalho, I; Friedag, P; Figuera, P; Koos, V; Meot, V H; Pauwels, D B; Jancso, A; Srebrny, J; Alves, E J; David bosne, E; Bengtsson, L; Kalkuehler, M; Albers, M; Bharuth-ram, K; Akkus, B; Hemmingsen, L B S; Pedersen, J T; Dos santos redondo, L M; Rubio barroso, B; Algora, A; Kozlov, V; Mavela, D L; Mokhles gerami, A; Keeley, N; Bernardo da silva, E; Unzueta solozabal, I; Schell, J; Szybowicz, M; Yang, X; Plavec, J; Lassen, J; Johnston, K; Coquard, L; Bloch, T P; Bonig, E S; Ignatov, A; Paschalis, S; Fernandez martinez, G; Schilling, M; Habermann, T; Von hahn, R; Minaya ramirez, E E; Manea, V; Moore, I D; Wang, Y; Saastamoinen, A J; Grahn, T; Herzan, A; Stolze, S M; Clement, E; Dijon, A; Shornikov, A; Lienard, E; Gibelin, J D; Pain, C; Canchel, G; Simpson, G S; Latrasse, L P; Huang, W; Forest, D H; Billowes, J; Flanagan, K; Strashnov, I; Binnersley, C L; Sanchez poncela, M; Simpson, J; Morrall, P S; Grant, A F; Charisopoulos, S; Lagogiannis, A; Bhattacharya, C; Olafsson, S; Stepaniuk, M; Tornqvist, H T; Heinz, A M; White iv, E R; Vermote, S L; Courtin, S; Marechal, F; Randisi, G; Kana, T; Rajabali, M M; Lannoo, B J M; Frederickx, R; De coster, T J C; Roovers, N; De lemos lima, T A; Stryjczyk, M; Dockx, K; Haller, S; Rizzi, M; Reichert, S B; Bonn, J; Thirolf, P G; Garcia rios, A R; Gugliermina, V M; Cubero campos, M A; Sanchez tembleque, V; Benito garcia, J; Senoville, M; Mountford, D J; Gelletly, W; Alharbi, T S T; Wilson, E; Rigby, S V; Andreoiu, C; Paul, E S; Harkness, L J; Judson, D S; Wraith, C; Van esbroeck, K; Wadsworth, R; Cubiss, J G; Harding, R D; Vaintraub, S; Mandal, S K; Scarpa, D; Hoff, P; Syed naeemul, H; Borcea, R; Balabanski, D L; Marginean, R; Rotaru, F; Rudolph, D; Fahlander, C H; Chudoba, V; Soic, N; Naidoo, D; Veselsky, M; Kliman, J; Raisanen, J A; Dietrich, M; Maung maung than, M M T; Reed, M W; Danchev, M T; Ray, J; Roy, M; Hammen, M; Recchia, F; Capponi, L; Veghne csatlos, M M; Fryar, J; Mirzadeh vaghefi, S P; Trindade pereira, A M; De pinho oliveira, G N; Bakenecker, A; Tramm, C; Germic, V; Morel, P A; Kowalczyk, M; Matejska-minda, M; Wolinska-cichocka, M; Ringvall moberg, A; Mantovan, R; Fransen, C H; Radeck, F; Schneiders, D W; Steinbach, T; Vibenholt, J E; Magnussen, M J; Stevnhoved, H M; Comas lijachev, V; Dasenbrock-gammon, N M; Perkowski, J; O'neill, G G; Matveev, Y; Wegner, M; Liu, Z; Perez alvarez, T; Cerato, L; Radchenko, V; Molholt, T E; Tabares giraldo, J A; Srnka, D; Dlouhy, Z; Beck, D; Werner, V R; Homm, I; Eliseev, S; Blaum, K; Probst, M B; Kaiser, C J; Martin, J A; Refsgaard, J; Peura, P J; Greenlees, P T; Auranen, K; Delahaye, P; Traykov, E K; Perez loureiro, D; Mery, A A; Couratin, C; Tsekhanovich, I; Lunney, D; Gaulard, C V; Althubiti, N A S; Mottram, A D; Cullen, D M; Das, S K; Van de walle, J; Mazzocchi, C; Jonson, B N G; Woehr, A; Lesher, S R; Zuber, K T; Filippin, L; De witte, H J; Van den bergh, P A M; Raabe, R; Depuydt, M J F; Radulov, D P; Elseviers, J; Dirkx, D; Da silva fenta, A E; Reynders, K L T; Atanasov, D; Delombaerde, L; De maesschalck, D; Parnefjord gustafsson, F O A; Dunlop, R A; Tarasava, K; Gernhaeuser, R A; Weinzierl, W; Berger, C; Wendt, K; Achtzehn, T; Gottwald, T; Schug, M; Rossel, R E; Dominguez reyes, R R; Briz monago, J A; Koester, U H; Bunce, M R; Bowry, M D; Nakhostin, M; Shearman, R; Cresswell, J R; Joss, D T; Gredley, A; Groombridge, D; Laird, A M; Aslanoglou, X; Siem, S; Weterings, J A; Renstrom, T; Szpak, B T; Luczkowski, M J; Ghita, D; Bezbakh, A; Soltz, R A; Bollmann, J; Bhattacharya, P; Roy, S; Rahaman, M A; Wlodarski, T; Carvalho soares, J; Barzakh, A; Schertz, F; Froemmgen, N E; Liberati, V; Foy, B E; Weinheimer, C P; Zboril, M; Simon, R E; Popescu, L A; Czosnyka, T; Miranda jana, P A; Leimbach, D; Naskrecki, R; Plociennik, W A; Ruchowska, E E; Chiara, C J; Eberth, J H; Thomas, T; Thole, P; Queiser, M T; Lo bianco, G; D'amico, F; Muller, S; Sanchez alarcon, R M; Tain enriquez, J L; Orrigo, S E A; Orlandi, R; Masango, S; Plazaola muguruza, F C; Lepareur, N G; Fiebig, J M; Ceylan, N; Wildner, E; Kowalska, M; Malbrunot, S; Garcia ruiz, R F; Pallada, S; Slezak, M; Roeckl, E; Schrieder, G H; Ilieva, S K; Koenig, K L; Amoretti, M A; Lommen, J M; Fynbo, H O U; Weyer, G O P; Koldste, G T; Madsboll, K; Jensen, J H; Nieminen, A M; Reponen, M; Villari, A; Thomas, J; Saint-laurent, M; Sorlin, O H; Carniol, B; Pereira lopez, J; Grevy, S; Plaisir, C; Marie-jeanne, M J; Georgiev, G P; Etile, A M; Le blanc, F M; Verney, D; Stefan, G I; Assie, M; Suzuki, D; Guillot, J; Vazquez rodriguez, L; Campbell, P; Deacon, A N; Ware, T; Flueras, A; Xie, L; Banerjee, K; Piersa, M; Galaviz redondo, D; Johansson, H T; Schwarz, S; Toysa, A S; Aumont, J; Sferrazza, M; Van duppen, P L E; Versyck, S; Dehaes, J; Bree, N C F; Neyskens, P; Carlier, L M F; De schepper, S; Dewolf, K W A; Kabir, L R; Khodery ahmad, M A; Zadvornaya, A; Renaud, M A; Xu, Z; Smolders, P; Krastev, P; Garrett, P E; Rapisarda, E; Reber, J A; Mattolat, C F; Raeder, S; Habs, D; Fraile prieto, L M; Vidal, M; Perez liva, M; Calvo portela, P; Ulla pedrera, F J; Wood, R T; Lalkovski, S; Page, R; Petri, M; Barton, C J; Nichols, A J; Vermeulen, M J; Bloor, D M; Henderson, J; Wilson, G L; De angelis, G; Buerger, A; Modamio hoybjor, V; Klintefjord, M L; Ingeberg, V W; Fornal, B A; Marginean, R; Sava, T; Kusoglu, A; Suvaila, R; Lica, R; Costache, C; Mihai, R; Ionescu, A; Baeck, T M; Fijalkowska, A G; Sedlak, M; Koskelo, O K; Kyaw myat, K M; Ganguly, B; Goncalves marques, J; Cardoso, S; Seliverstov, M; Niessen, B D; Gutt, L E; Chapman, R; Spagnoletti, P N; Lopes, C; De oliveira amorim, C; Batista lopes, C M; Araujo, J; Schielke, S J; Daugas, J R; Gaudefroy, L; Chevrier, R; Szunyogh, D M; Napiorkowski, P J; Wrzosek-lipska, K; Wahl, U; Catarino, N; Pereira carvalho alves de sequeira, M; Walters, W; Hess, H E; Holler, A; Bettermann, L; Geibel, K; Taprogge, J; Lewandowski, L T N; Manchado de sola, F; Das gupta, S; Thulstrup, P W; Heinz, U; Nogwanya, T; Neidherr, D M; Morales lopez, A I; Gumenyuk, O; Peaker, A R; Wakabayashi, Y; Abrahams, K J; Martin montes, E J; Mach, H A; Souza ribeiro junior, I; He, J; Chalil, A; Xing, R; Giles, T J; Dorsival, A; Trujillo hernandez, J S; Kalaninova, Z; Andel, B; Venos, D; Kraemer, J; Saha, S; Neugart, R; Eronen, T O; Kreim, K D; Heck, M K; Goncharov, M; Karthein, J; Julin, R J; Jakobsson, E H U; Eleon, C; Achouri, N L; Grinyer, G F; Fontbonne, C M; Alfaurt, P; Lynch, K M; Wilkins, S G; Brown, A R; Imai, N; Pomorski, M J; Janiak, L; Nilsson, T; Stroke, H H; Stanja, J; Dangelser, E; Heenen, P; Godefroid, M; Mallion, S N; Diriken, J V J; Ghys, L H L; Khamehchi, M A; Van beveren, C; Gins, W A M; Finlay, P E J; Bouma, J T; Augustyns, V; Stegemann, S T; Koszorus, A; Mcnulty, J F; Lin, P; Ohlert, C M; Schwerdtfeger, W; Tengblad, O; Becerril reyes, A D; Perea martinez, A; Martinez perez, M C; Margerin, V; Rudigier, M; Alexander, T D; Patel, Z V; Hammond, N; Wearing, F; Patel, A; Jenkins, D G; Corradi, L; Galtarossa, F; Debernardi, A; Giacoppo, F; Tveten, G M; Malatji, K L; Krolas, W A; Stanoiu, M A; Rickert, E U; Ter-akopian, G; Cline, D; Riihimaeki, I A; Simon, K D; Wagner, F E; Turker, M; Neef, M H; Coombes, B J; Jakubek, J; Vagena, E; Bottoni, S; Nishimura, K; Correia, J; Rodrigues valdrez, C J; Adhikari, R; Ostrowski, A N; Hallmann, O; Scheck, M; Wady, P T; Lane, J; Krasznahorkay, A J; Kunne sohler, D; Meaney, A J; Baptista barbosa, M; Hochschulz, F; Roig, O; Behan, C C; Kargoll, S; Kemnitz, S; Carvalho teixeira, R C; Redondo cubero, A; Tallarida, G; Kaczarowski, R; Finke, F; Linnemann, A; Altenkirch, R; Saed-samii, N; Ansari, S H; Dlamini, W B; Adoons, V N; Ronning, C R; Wiedeking, M; Herlert, A J; Mehl, C V; Judge, S M; Gaertner, D; Divinskyi, S; Zagoraios, G; Boztosun, I; Van zyl, J J; Catherall, R; Lettry, J; Wenander, F J C; Zakoucky, D; Catchen, G L; Noertershaeuser, W; Kroell, T; Leske, J; Shubina, D; Murray, I M; Pancin, J; Delaunay, F; Poincheval, J J L; Audirac, L L; Gerbaux, M T; Aouadi, M; Sole, P G P; Fallot, M P; Onillon, A; Duchemin, C; Formento cavaier, R; Audi, G; Boukhari, A; Lau, C; Martin, J A; Barre, N H; Berry, T A; Procter, T J; Bladen, L K; Axiotis, M; Muto, S; Jeong, S C; Hirayama, Y; Korgul, A B; Minamisono, K; Bingham, C R; Aprahamian, A; Bucher, B M; Severijns, N; Huyse, M L; Himpe, P; Ferrer garcia, R; Marchi, T; Sambi, S; Budincevic, I; Neven, M; Verlinde, M N S; Bomans, P; Romano, N; Maugeri, E A; Klupp, S C; Dehn, M H; Heinke, R M; Naubereit, P; Maira vidal, A; Vedia fernandez, M V; Ibanez garcia, P B; Bruyneel, B J E; Materna, T; Hadynska-klek, K; Al-dahan, N; Alazemi, N; Carroll, R J; Babcock, C; Patronis, N; Eleme, Z; Dhal, A; Sahin, E; Goergen, A; Maj, A; Bednarczyk, P A; Borcea, C; Negoita, F; Suliman, G; Marginean, N M; Sotty, C O; Negret, A L; Nae, S A; Nita, C; Golubev, P I; Knyazev, A; Jost, C U; Petrik, K; Vaeyrynen, S A; Dracoulis, G D; Uher, J; Fernandez dominguez, B; Chakraborty, P; Avigo, R; Falahat, S; Lekovic, F; Dorrer, H J; Mengoni, D; Derkx, X; Angus, L J; Sandhu, K S; Gregor, E; Kelly, N A; Byrne, D J; Haas, H; Lourenco, A A; Sousa pereira, S M; Sousa, J B; De melo mendonca, T M; Tavares de sousa, C; Guerreiro dos santos oliveira custodio, L M; Da rocha rodrigues, P M; Yamaguchi, T; Thompson, P C; Rosenbusch, M; Wienholtz, F; Fischer, P; Iwanicki, J S; Rusek, K M; Hanstorp, D; Vetter, U; Wolak, J M; Park, S H; Warr, N V; Doornenbal, P C; Imig, A; Seidlitz, M; Moschner, K; Vogt, A; Kaya, L; Martel bravo, I; Orduz, A K; Serot, O; Majola, S N; Litvinov, Y; Bommert, M; Hensel, S; Markevich, V; Nishio, K; Ota, S; Matos, I; Zenkevich, A; Picado sandi, E; Forstner, O; Hu, B; Ntshangase, S S; Sanchez-segovia, J

    2002-01-01

    The experiments aim at a broad exploration of the properties of atomic nuclei far away from the region of beta stability. Furthermore, the unique radioactive beams of over 60~elements produced at the on-line isotope separators ISOLDE-2 and ISOLDE-3 are used in a wide programme of atomic, solid state and surface physics. Around 300 scientists are involved in the project, coming from about 70 laboratories. \\\\ \\\\ The electromagnetic isotope separators are connected on-line with their production targets in the extracted 600 MeV proton or 910~MeV Helium-3 beam of the Synchro-Cyclotron. Secondary beams of radioactive isotopes are available at the facility in intensities of 10$^1

  13. Familial Microscopic Colitis

    Directory of Open Access Journals (Sweden)

    Ayman Assad Abdo

    2001-01-01

    Full Text Available Collagenous and lymphocytic colitis are two inflammatory conditions of the colon that are often collectively referred to as microscopic colitis. The present report describes what is believed to be the third published case of familial microscopic colitis. A 55-year-old woman who suffered from chronic diarrhea was diagnosed with lymphocytic colitis on colonic biopsy. Subsequently, her 36-year-old daughter was diagnosed with collagenous colitis. The familial occurrence of these diseases may support an immunological hypothesis for their etiology. In addition, it supports the assumption that collagenous and lymphocytic colitis are two manifestations of the same disease process rather than two completely separate entities. The familial tendency of this disease may make a case for early colonoscopy and biopsy in relatives of patients diagnosed with microscopic colitis if they present with suggestive symptoms.

  14. PATTERN RECOGNITION STUDIES OF HALOGENATED ORGANIC COMPOUNDS USING CONDUCTING POLYMER SENSOR ARRAYS. (R825323)

    Science.gov (United States)

    Direct measurement of volatile and semivolatile halogenated organic compounds of environmental interest was carried out using arrays of conducting polymer sensors. Mathematical expressions of the sensor arrays using microscopic polymer network model is described. A classical, non...

  15. Scanning transmission electron microscope

    NARCIS (Netherlands)

    Kruit, P.

    2006-01-01

    The invention relates to a scanning transmission electron microscope comprising an electron source, an electron accelerator and deflection means for directing electrons emitted by the electron source at an object to be examined, and in addition a detector for detecting electrons coming from the

  16. Microscope on Mars

    Science.gov (United States)

    2004-01-01

    This image taken at Meridiani Planum, Mars by the panoramic camera on the Mars Exploration Rover Opportunity shows the rover's microscopic imager (circular device in center), located on its instrument deployment device, or 'arm.' The image was acquired on the ninth martian day or sol of the rover's mission.

  17. MICROSCOPIC, PHYSICOCHEMICAL AND CHROMATOGRAPHIC ...

    African Journals Online (AJOL)

    Peters

    sulphated ash 19.6%, water-soluble ash 6.8%, alcohol-soluble extractive 9.5% and water-soluble extractive 24.1%. Chromatographic fingerprints of ... chloral hydrate, mounted in dilute glycerol on a microscope slide and viewed at different ... was washed off in water and the sample mounted on a slide with glycerin.

  18. Terahertz scanning probe microscope

    NARCIS (Netherlands)

    Klapwijk, T.M.

    2014-01-01

    The invention provides aterahertz scanning probe microscope setup comprising (i) a terahertz radiation source configured to generate terahertz radiation; (ii) a terahertz lens configured to receive at least part of the terahertz radiation from the terahertz radiation source; (iii) a cantilever unit

  19. SPM: Scanning positron microscope

    Directory of Open Access Journals (Sweden)

    Marcel Dickmann

    2015-08-01

    Full Text Available The Munich scanning positron microscope, operated by the Universität der Bundeswehr München and the Technische Universität München, located at NEPOMUC, permits positron lifetime measurements with a lateral resolution in the µm range and within an energy range of 1 – 20 keV.

  20. Innovative Columnar Type of Grid Array SJ BIST HALT Method Project

    Data.gov (United States)

    National Aeronautics and Space Administration — Ridgetop will develop a superior method for testing and qualifying columnar type of grid arrays such as field programmable gate arrays (FPGAs) packaged in column...

  1. Sigma Delta Signal Processing on Via-Configurable Arrays

    Science.gov (United States)

    2016-03-31

    Sigma Delta Signal Processing on Via-Configurable Arrays Jim Kemerling Triad Semiconductor, Inc. Winston-Salem, NC 27103 Abstract: Sigma -Delta...Mask Programmable Analog Array; Mixed-Signal ASIC; Sigma Delta Modulation; Structured Array; Switched Capacitor Circuits; Via-Configurable Array... phase of the input signal at the rate determined by the M output. Figure 9 shows the simulation results and Figure 10 shows the tiles used in the

  2. Building an artificial actin cortex on microscopic pillar arrays

    NARCIS (Netherlands)

    Ayadi, R; Roos, W H

    2015-01-01

    Eukaryotic cells obtain their morphology and mechanical strength from the cytoskeleton and in particular from the cross-linked actin network that branches throughout the whole cell. This actin cortex lies like a quasi-two-dimensional (2D) biopolymer network just below the cell membrane, to which it

  3. Ion photon emission microscope

    Science.gov (United States)

    Doyle, Barney L.

    2003-04-22

    An ion beam analysis system that creates microscopic multidimensional image maps of the effects of high energy ions from an unfocussed source upon a sample by correlating the exact entry point of an ion into a sample by projection imaging of the ion-induced photons emitted at that point with a signal from a detector that measures the interaction of that ion within the sample. The emitted photons are collected in the lens system of a conventional optical microscope, and projected on the image plane of a high resolution single photon position sensitive detector. Position signals from this photon detector are then correlated in time with electrical effects, including the malfunction of digital circuits, detected within the sample that were caused by the individual ion that created these photons initially.

  4. Microscopic approach to polaritons

    DEFF Research Database (Denmark)

    Skettrup, Torben

    1981-01-01

    The interaction between excitons and light has been investigated in detail. The perturbational approach turns out to be invalid. However, an exact solution can be obtained directly from the Schrödinger equation for a fixed light field. This solution corresponds to a nonlinear optical response...... contrary to experimental experience. In order to remove this absurdity the semiclassical approach must be abandoned and the electromagnetic field quantized. A simple microscopic polariton model is then derived. From this the wave function for the interacting exciton-photon complex is obtained...... of light of the crystal. The introduction of damping smears out the excitonic spectra. The wave function of the polariton, however, turns out to be very independent of damping up to large damping values. Finally, this simplified microscopic polariton model is compared with the exact solutions obtained...

  5. Scanning transmission electron microscope

    OpenAIRE

    Kruit, P.

    2006-01-01

    The invention relates to a scanning transmission electron microscope comprising an electron source, an electron accelerator and deflection means for directing electrons emitted by the electron source at an object to be examined, and in addition a detector for detecting electrons coming from the object and, connected to the detector, a device for processing the detected electrons so as to form an object image, wherein a beam splitter is provided for dividing the electron beam from the electron...

  6. Color Laser Microscope

    Science.gov (United States)

    Awamura, D.; Ode, T.; Yonezawa, M.

    1987-04-01

    A color laser microscope utilizing a new color laser imaging system has been developed for the visual inspection of semiconductors. The light source, produced by three lasers (Red; He-Ne, Green; Ar, Blue; He-Cd), is deflected horizontally by an AOD (Acoustic Optical Deflector) and vertically by a vibration mirror. The laser beam is focused in a small spot which is scanned over the sample at high speed. The light reflected back from the sample is reformed to contain linear information by returning to the original vibration mirror. The linear light is guided to the CCD image sensor where it is converted into a video signal. Individual CCD image sensors are used for each of the three R, G, or B color image signals. The confocal optical system with its laser light source yields a color TV monitor image with no flaring and a much sharper resolution than that of the conventional optical microscope. The AOD makes possible a high speed laser scan and a NTSC or PAL TV video signal is produced in real time without any video memory. Since the light source is composed of R, G, and B laser beams, color separation superior to that of white light illumination is achieved. Because of the photometric linearity of the image detector, the R, G, and B outputs of the system are most suitably used for hue analysis. The CCD linear image sensors in the optical system produce no geometrical distortion, and good color registration is available principally. The output signal can be used for high accuracy line width measuring. The many features of the color laser microscope make it ideally suited for the visual inspection of semiconductor processing. A number of these systems have already been installed in such a capacity. The Color Laser Microscope can also be a very useful tool for the fields of material engineering and biotechnology.

  7. Examining the Real Merits of the Virtual Microscope

    Science.gov (United States)

    Hennessy, Ronan; Meere, Pat; Ho, Timsie; Menuge, Julian; Tyrrell, Shane; Kamber, Balz; Higgs, Bettie; Kelley, Simon

    2017-04-01

    The Geoscience e-Laboratory (GeoLAB) project is a cooperative digital petrological microscopy technology enhanced learning (TEL) resource development project involving the four main university geoscience teaching centres in Ireland. Collaborating with the Open University (UK), a new digital library of petrographic thin sections has been added to the Virtual Microscope for Earth Sciences (VMfES) online repository. The collection was compiled with a view to introducing high-quality samples to teaching programmes in a manner that hitherto was limited by sample and microscope availability and cost and the temporal limits of laboratory access. The project has proceeded to explore the pedagogical implications of using the Virtual Microscope in teaching programmes. Online assessments and self-guided exercises developed using applications such as Google Forms have been introduced into programmes at each centre, and complimented by tutorial and interactive videos designed to support self-guided learning. The GeoLab project is reporting on the pedagogical implications of providing students with unimpeded access to high-quality petrographic learning resources during the term of semester and in advance of student assessments. Additionally, the project is collating data on the perceptions of both teachers and learners to using online learning media in mineralogy and petrology programmes, and if there are benefits therein to the more traditional styles of petrology and microscopy teaching and learning.

  8. Atomic Force Microscope

    Energy Technology Data Exchange (ETDEWEB)

    Day, R.D.; Russell, P.E.

    1988-12-01

    The Atomic Force Microscope (AFM) is a recently developed instrument that has achieved atomic resolution imaging of both conducting and non- conducting surfaces. Because the AFM is in the early stages of development, and because of the difficulty of building the instrument, it is currently in use in fewer than ten laboratories worldwide. It promises to be a valuable tool for obtaining information about engineering surfaces and aiding the .study of precision fabrication processes. This paper gives an overview of AFM technology and presents plans to build an instrument designed to look at engineering surfaces.

  9. Photography with a Microscope

    Science.gov (United States)

    Rost, Fred; Oldfield, Ron

    2000-03-01

    This beautifully illustrated book describes the methods used to record images viewed through a microscope. The text describes the principles and practices of photomicrography, and is written for all who take photomicrographs, beginners and/or experienced practitioners. The authors describe techniques that may be applied to many disciplines for teaching, research, archives, or pleasure. The book includes chapters on standard photography, modern digital techniques, methods for improving contrast, and a short chapter on drawing. In addition to its value as a work of reference, the authors' clear, didactic style makes this book suitable as a textbook for courses in photomicrography and/or elementary light microscopy.

  10. Athena Microscopic Imager investigation

    OpenAIRE

    Herkenhoff, K. E.

    2003-01-01

    The Athena science payload on the Mars Exploration Rovers (MER) includes the Microscopic Imager (MI). The MI is a fixed-focus camera mounted on the end of an extendable instrument arm, the Instrument Deployment Device (IDD). The MI was designed to acquire images at a spatial resolution of 30 microns/pixel over a broad spectral range (400–700 nm). The MI uses the same electronics design as the other MER cameras but has optics that yield a field of view of 31 31 mm across a 1024...

  11. FPGAs for software programmers

    CERN Document Server

    Hannig, Frank; Ziener, Daniel

    2016-01-01

    This book makes powerful Field Programmable Gate Array (FPGA) and reconfigurable technology accessible to software engineers by covering different state-of-the-art high-level synthesis approaches (e.g., OpenCL and several C-to-gates compilers). It introduces FPGA technology, its programming model, and how various applications can be implemented on FPGAs without going through low-level hardware design phases. Readers will get a realistic sense for problems that are suited for FPGAs and how to implement them from a software designer’s point of view. The authors demonstrate that FPGAs and their programming model reflect the needs of stream processing problems much better than traditional CPU or GPU architectures, making them well-suited for a wide variety of systems, from embedded systems performing sensor processing to large setups for Big Data number crunching. This book serves as an invaluable tool for software designers and FPGA design engineers who are interested in high design productivity through behavi...

  12. Field-portable lensfree tomographic microscope.

    Science.gov (United States)

    Isikman, Serhan O; Bishara, Waheb; Sikora, Uzair; Yaglidere, Oguzhan; Yeah, John; Ozcan, Aydogan

    2011-07-07

    We present a field-portable lensfree tomographic microscope, which can achieve sectional imaging of a large volume (∼20 mm(3)) on a chip with an axial resolution of optic waveguide are controlled through a cost-effective micro-processor to sequentially illuminate the sample from different angles to record lensfree holograms of the sample that is placed on the top of a digital sensor array. In order to generate pixel super-resolved (SR) lensfree holograms and hence digitally improve the achievable lateral resolution, multiple sub-pixel shifted holograms are recorded at each illumination angle by electromagnetically actuating the fibre-optic waveguides using compact coils and magnets. These SR projection holograms obtained over an angular range of ±50° are rapidly reconstructed to yield projection images of the sample, which can then be back-projected to compute tomograms of the objects on the sensor-chip. The performance of this compact and light-weight lensfree tomographic microscope is validated by imaging micro-beads of different dimensions as well as a Hymenolepis nana egg, which is an infectious parasitic flatworm. Achieving a decent three-dimensional spatial resolution, this field-portable on-chip optical tomographic microscope might provide a useful toolset for telemedicine and high-throughput imaging applications in resource-poor settings. This journal is © The Royal Society of Chemistry 2011

  13. Electron microscope phase enhancement

    Science.gov (United States)

    Jin, Jian; Glaeser, Robert M.

    2010-06-15

    A microfabricated electron phase shift element is used for modifying the phase characteristics of an electron beam passing though its center aperture, while not affecting the more divergent portion of an incident beam to selectively provide a ninety-degree phase shift to the unscattered beam in the back focal plan of the objective lens, in order to realize Zernike-type, in-focus phase contrast in an electron microscope. One application of the element is to increase the contrast of an electron microscope for viewing weakly scattering samples while in focus. Typical weakly scattering samples include biological samples such as macromolecules, or perhaps cells. Preliminary experimental images demonstrate that these devices do apply a ninety degree phase shift as expected. Electrostatic calculations have been used to determine that fringing fields in the region of the scattered electron beams will cause a negligible phase shift as long as the ratio of electrode length to the transverse feature-size aperture is about 5:1. Calculations are underway to determine the feasibility of aspect smaller aspect ratios of about 3:1 and about 2:1.

  14. Microscopic colitis. A review.

    Science.gov (United States)

    Brown, William R; Tayal, Shalini

    2013-06-01

    Microscopic colitis (MC) is characterized by a triad of watery diarrhea, usually normal colonoscopic findings and typical microscopic findings. Two distinct histological forms of MC have been defined: lymphocytic colitis and collagenous colitis, but overlapping features may be present. The incidence of MC appears to be rising and in some countries it may account for as many as 10-20% of patients with non-bloody watery diarrhea. The cause of MC remains unknown and is likely to be multifactorial. The pathogenesis is poorly defined, and numerous immunological abnormalities have been reported. MC is commonly associated with autoimmune diseases including celiac disease. Use of various medications, most notably non-steroidal anti-inflammatory agents and proton pump inhibitors, have been etiologically implicated but not firmly established as causative. In imperfect trials several agents have been reported to be effective in the treatment of MC; budesonide is the best studied and evidence supporting its effectiveness is the most persuasive. In cases of otherwise unexplained watery, non-bloody diarrhea, MC should be considered and colonic biopsied specimens should be taken of normal-appearing mucosa. © 2013 The Authors. Journal of Digestive Diseases © 2013 Wiley Publishing Asia Pty Ltd and Chinese Medical Association Shanghai Branch, Chinese Society of Gastroenterology, Renji Hospital Affiliated to Shanghai Jiaotong University School of Medicine.

  15. Rapid geodesic mapping of brain functional connectivity: implementation of a dedicated co-processor in a field-programmable gate array (FPGA) and application to resting state functional MRI.

    Science.gov (United States)

    Minati, Ludovico; Cercignani, Mara; Chan, Dennis

    2013-10-01

    Graph theory-based analyses of brain network topology can be used to model the spatiotemporal correlations in neural activity detected through fMRI, and such approaches have wide-ranging potential, from detection of alterations in preclinical Alzheimer's disease through to command identification in brain-machine interfaces. However, due to prohibitive computational costs, graph-based analyses to date have principally focused on measuring connection density rather than mapping the topological architecture in full by exhaustive shortest-path determination. This paper outlines a solution to this problem through parallel implementation of Dijkstra's algorithm in programmable logic. The processor design is optimized for large, sparse graphs and provided in full as synthesizable VHDL code. An acceleration factor between 15 and 18 is obtained on a representative resting-state fMRI dataset, and maps of Euclidean path length reveal the anticipated heterogeneous cortical involvement in long-range integrative processing. These results enable high-resolution geodesic connectivity mapping for resting-state fMRI in patient populations and real-time geodesic mapping to support identification of imagined actions for fMRI-based brain-machine interfaces. Copyright © 2013 IPEM. Published by Elsevier Ltd. All rights reserved.

  16. Anisotropic contrast optical microscope.

    Science.gov (United States)

    Peev, D; Hofmann, T; Kananizadeh, N; Beeram, S; Rodriguez, E; Wimer, S; Rodenhausen, K B; Herzinger, C M; Kasputis, T; Pfaunmiller, E; Nguyen, A; Korlacki, R; Pannier, A; Li, Y; Schubert, E; Hage, D; Schubert, M

    2016-11-01

    An optical microscope is described that reveals contrast in the Mueller matrix images of a thin, transparent, or semi-transparent specimen located within an anisotropic object plane (anisotropic filter). The specimen changes the anisotropy of the filter and thereby produces contrast within the Mueller matrix images. Here we use an anisotropic filter composed of a semi-transparent, nanostructured thin film with sub-wavelength thickness placed within the object plane. The sample is illuminated as in common optical microscopy but the light is modulated in its polarization using combinations of linear polarizers and phase plate (compensator) to control and analyze the state of polarization. Direct generalized ellipsometry data analysis approaches permit extraction of fundamental Mueller matrix object plane images dispensing with the need of Fourier expansion methods. Generalized ellipsometry model approaches are used for quantitative image analyses. These images are obtained from sets of multiple images obtained under various polarizer, analyzer, and compensator settings. Up to 16 independent Mueller matrix images can be obtained, while our current setup is limited to 11 images normalized by the unpolarized intensity. We demonstrate the anisotropic contrast optical microscope by measuring lithographically defined micro-patterned anisotropic filters, and we quantify the adsorption of an organic self-assembled monolayer film onto the anisotropic filter. Comparison with an isotropic glass slide demonstrates the image enhancement obtained by our method over microscopy without the use of an anisotropic filter. In our current instrument, we estimate the limit of detection for organic volumetric mass within the object plane of ≈49 fg within ≈7 × 7 μm2 object surface area. Compared to a quartz crystal microbalance with dissipation instrumentation, where contemporary limits require a total load of ≈500 pg for detection, the instrumentation demonstrated here improves

  17. THz wave emission microscope

    Science.gov (United States)

    Yuan, Tao

    Sensing and imaging using Terahertz (THz) radiation has attracted more and more interest in the last two decades thanks to the abundant material 'finger prints' in the THz frequency range. The low photon energy also makes THz radiation an attractive tool for nondestructive evaluation of materials and devices, biomedical applications, security checks and explosive screening. Due to the long wavelength, the far-field THz wave optical systems have relatively low spatial resolution. This physical limitation confines THz wave sensing and imaging to mostly macro-size samples. To investigate local material properties or micro-size structures and devices, near-field technology has to be employed. In this dissertation, the Electro-Optical THz wave emission microscope is investigated. The basic principle is to focus the femtosecond laser to a tight spot on a thin THz emitter layer to produce a THz wave source with a similar size as the focus spot. The apparatus provides a method for placing a THz source with sub-wavelength dimension in the near-field range of the investigated sample. Spatial resolution to the order of one tenth of the THz wavelength is demonstrated by this method. The properties of some widely used THz wave emission materials under tight focused pump light are studied. As an important branch of THz time domain spectroscopy (THz-TDS), THz wave emission spectroscopy has been widely used as a tool to investigate the material physics, such as energy band structure, carrier dynamics, material nonlinear properties and dynamics. As the main work of this dissertation, we propose to combine the THz wave emission spectroscopy with scanning probe microscopy (SPM) to build a tip-assisted THz wave emission microscope (TATEM), which is a valuable extension to current SPM science and technology. Illuminated by a femtosecond laser, the biased SPM tip forms a THz wave source inside the sample beneath the tip. The source size is proportional to the apex size of the tip so

  18. Automates programmables Partie 3 : Langages de programmation

    CERN Document Server

    International Electrotechnical Commission. Geneva

    1993-01-01

    S'applique à la représentation imprimée et affichée, à l'aide des caractères ISO/CEI 646, des langages de programmation devant être utilisés pour les automates programmables. Spécifie la syntaxe et la sémantique.

  19. Imaging arrangement and microscope

    Science.gov (United States)

    Pertsinidis, Alexandros; Chu, Steven

    2015-12-15

    An embodiment of the present invention is an imaging arrangement that includes imaging optics, a fiducial light source, and a control system. In operation, the imaging optics separate light into first and second tight by wavelength and project the first and second light onto first and second areas within first and second detector regions, respectively. The imaging optics separate fiducial light from the fiducial light source into first and second fiducial light and project the first and second fiducial light onto third and fourth areas within the first and second detector regions, respectively. The control system adjusts alignment of the imaging optics so that the first and second fiducial light projected onto the first and second detector regions maintain relatively constant positions within the first and second detector regions, respectively. Another embodiment of the present invention is a microscope that includes the imaging arrangement.

  20. Mars Under the Microscope

    Science.gov (United States)

    2004-01-01

    This magnified look at the martian soil near the Mars Exploration Rover Opportunity's landing site, Meridiani Planum, shows coarse grains sprinkled over a fine layer of sand. The image was captured by the rover's microscopic imager on the 10th day, or sol, of its mission. Scientists are intrigued by the spherical rocks, which can be formed by a variety of geologic processes, including cooling of molten lava droplets and accretion of concentric layers of material around a particle or 'seed.'The examined patch of soil is 3 centimeters (1.2 inches) across. The circular grain in the lower left corner is approximately 3 millimeters (.12 inches) across, or about the size of a sunflower seed.

  1. Microscopic Theory of Transconductivity

    Directory of Open Access Journals (Sweden)

    A. P. Jauho

    1998-01-01

    Full Text Available Measurements of momentum transfer between two closely spaced mesoscopic electronic systems, which couple via Coulomb interaction but where tunneling is inhibited, have proven to be a fruitful method of extracting information about interactions in mesoscopic systems. We report a fully microscopic theory for transconductivity σ12, or, equivalently, momentum transfer rate between the system constituents. Our main formal result expresses the transconductivity in terms of two fluctuation diagrams, which are topologically related, but not equivalent to, the Azlamazov-Larkin and Maki-Thompson diagrams known for superconductivity. In the present paper the magnetic field dependence of σ12 is discussed, and we find that σ12(B is strongly enhanced over its zero field value, and it displays strong features, which can be understood in terms of a competition between density-of-states and screening effects.

  2. A programmable associative memory for track finding

    Energy Technology Data Exchange (ETDEWEB)

    Bardi, A.; Belforte, S.; Donati, S.; Galeotti, S.; Giannetti, P.; Morsani, F.; Passuello, D.; Spinella, F. [Istituto Nazionale di Fisica Nucleare, Pisa (Italy); Cerri, A.; Punzi, G.; Ristori, L. [Scuola Normale Superiore, Piazza dei Cavalieri 7, 56100 Pisa (Italy); Dell`Orso, M.; Meschi, E. [Dipartimento di Fisica, Universita di Pisa, Piazza Torricelli 2, 56100 Pisa (Italy); Leger, A.; Speer, T.; Wu, X. [Departement de Physique Nucleaire et Corpusculaire, Universite de Geneve, 24 Quai Ernest-Ansermet, CH-1211 Geneve (Switzerland)

    1998-08-21

    We present a device, based on the concept of associative memory for pattern recognition, dedicated to on-line track finding in high-energy physics experiments. A large pattern bank, describing all possible tracks, can be organized into field programmable gate arrays where all patterns are compared in parallel to data coming from the detector during readout. Patterns, recognized among 2{sup 66} possible combinations, are output in a few 30 MHz clock cycles. Programmability results in a flexible, simple architecture and it allows to keep up smoothly with technology improvements. (orig.) 4 refs.

  3. Fabrication and characterization of polydimethylsiloxane concave microlens array

    Science.gov (United States)

    Feng, Li; Sihai, Chen; Huan, Luo; Yifan, Zhou; Jianjun, Lai; Yiqing, Gao

    2012-06-01

    Concave microlens array is fabricated with PDMS (polydimethylsiloxane) material. Resist thermal reflow method and reverse pattern replication method are employed to fabricate the concave microlens array. The optical performance of the PDMS concave microlens array is analyzed with ray-trace method. Profile of the PDMS concave microlens array is observed by metallographic microscope and Talystep. It is indicated by the results that the surface profile of the PDMS concave microlens array is clear and distinct. Optical properties are also tested with Beamprofiler system. The shine spots on the focal plane of the microscope objective are of highly uniformity, and essentially coincide well with the simulation result. The PDMS concave microlens array has potential application in many optoelectronic devices, such as diffusers and scanners.

  4. Learning Media Programme

    NARCIS (Netherlands)

    Westera, Wim

    2009-01-01

    Westera, W. (2009). Learning Media Programme. Introductory presentation of Learning Media Programme for visitors of Kavala University of Technology, Kavala, Greece and National Institute of Multimedia Education, Chiba, Japan. March, 2, 2009, Heerlen, The Netherlands.

  5. River research programme

    CSIR Research Space (South Africa)

    Ferrar, AA

    1988-01-01

    Full Text Available The need for a comprehensive, multidisciplinary research programme for river ecosystems is described. The scope of the programme needs to include basic descriptions of a systems and biota, the testing and development of functional theory...

  6. Optical Tweezers Array and Nimble Tweezers Probe Generated by Spatial- Light Modulator

    Science.gov (United States)

    Decker, Arthur J.; Jassemnejad, Baha; Seibel, Robin E.; Weiland, Kenneth E.

    2003-01-01

    An optical tweezers is being developed at the NASA Glenn Research Center as a visiblelight interface between ubiquitous laser technologies and the interrogation, visualization, manufacture, control, and energization of nanostructures such as silicon carbide (SiC) nanotubes. The tweezers uses one or more focused laser beams to hold micrometer-sized particles called tools (sometimes called tips in atomic-force-microscope terminology). A strongly focused laser beam has an associated light-pressure gradient that is strong enough to pull small particles to the focus, in spite of the oppositely directed scattering force; "optical tweezers" is the common term for this effect. The objective is to use the tools to create carefully shaped secondary traps to hold and assemble nanostructures that may contain from tens to hundreds of atoms. The interaction between a tool and the nanostructures is to be monitored optically as is done with scanning probe microscopes. One of the initial efforts has been to create, shape, and control multiple tweezers beams. To this end, a programmable spatial-light modulator (SLM) has been used to modify the phase of a laser beam at up to 480 by 480 points. One program creates multiple, independently controllable tweezer beams whose shapes can be tailored by making the SLM an adaptive mirror in an interferometer (ref. 1). The beams leave the SLM at different angles, and an optical Fourier transform maps these beams to different positions in the focal plane of a microscope objective. The following figure shows two arrays of multiple beams created in this manner. The patterns displayed above the beam array control the intensity-to-phase transformation required in programming the SLM. Three of the seven beams displayed can be used as independently controllable beams.

  7. Transmission electron microscope CCD camera

    Science.gov (United States)

    Downing, Kenneth H.

    1999-01-01

    In order to improve the performance of a CCD camera on a high voltage electron microscope, an electron decelerator is inserted between the microscope column and the CCD. This arrangement optimizes the interaction of the electron beam with the scintillator of the CCD camera while retaining optimization of the microscope optics and of the interaction of the beam with the specimen. Changing the electron beam energy between the specimen and camera allows both to be optimized.

  8. Proper alignment of the microscope.

    Science.gov (United States)

    Rottenfusser, Rudi

    2013-01-01

    The light microscope is merely the first element of an imaging system in a research facility. Such a system may include high-speed and/or high-resolution image acquisition capabilities, confocal technologies, and super-resolution methods of various types. Yet more than ever, the proverb "garbage in-garbage out" remains a fact. Image manipulations may be used to conceal a suboptimal microscope setup, but an artifact-free image can only be obtained when the microscope is optimally aligned, both mechanically and optically. Something else is often overlooked in the quest to get the best image out of the microscope: Proper sample preparation! The microscope optics can only do its job when its design criteria are matched to the specimen or vice versa. The specimen itself, the mounting medium, the cover slip, and the type of immersion medium (if applicable) are all part of the total optical makeup. To get the best results out of a microscope, understanding the functions of all of its variable components is important. Only then one knows how to optimize these components for the intended application. Different approaches might be chosen to discuss all of the microscope's components. We decided to follow the light path which starts with the light source and ends at the camera or the eyepieces. To add more transparency to this sequence, the section up to the microscope stage was called the "Illuminating Section", to be followed by the "Imaging Section" which starts with the microscope objective. After understanding the various components, we can start "working with the microscope." To get the best resolution and contrast from the microscope, the practice of "Koehler Illumination" should be understood and followed by every serious microscopist. Step-by-step instructions as well as illustrations of the beam path in an upright and inverted microscope are included in this chapter. A few practical considerations are listed in Section 3. Copyright © 2013 Elsevier Inc. All rights

  9. A fluorescence scanning electron microscope

    OpenAIRE

    Kanemaru, Takaaki; Hirata, Kazuho; Takasu, Shin-ichi; Isobe, Shin-Ichiro; Mizuki, Keiji; Mataka, Shuntaro; Nakamura, Kei-ichiro

    2010-01-01

    Fluorescence techniques are widely used in biological research to examine molecular localization, while electron microscopy can provide unique ultrastructural information. To date, correlative images from both fluorescence and electron microscopy have been obtained separately using two different instruments, i.e. a fluorescence microscope (FM) and an electron microscope (EM). In the current study, a scanning electron microscope (SEM) (JEOL JXA8600 M) was combined with a fluorescence digital c...

  10. Quad Ropes: Immutable, Declarative Arrays with Parallelizable Operations

    DEFF Research Database (Denmark)

    Biermann, Florian; Sestoft, Peter

    2017-01-01

    to let users choose between different array-like data structures. Instead, one should use the same, somewhat performance-robust, representation for every programming task. Quad ropes roughly retain array efficiency, as long as programmers express their programs using high-level constructs. Moreover...

  11. Scanning Electron Microscope Analysis System

    Data.gov (United States)

    Federal Laboratory Consortium — This facility provides the capability to examine surfaces microscopically with high resolution (5 nanometers), perform micro chemical analyses of these surfaces, and...

  12. Photon scanning tunneling microscope in combination with a force microscope

    NARCIS (Netherlands)

    Moers, M.H.P.; Moers, M.H.P.; Tack, R.G.; van Hulst, N.F.; Bölger, B.; Bölger, B.

    1994-01-01

    The simultaneous operation of a photon scanning tunneling microscope with an atomic force microscope is presented. The use of standard atomic force silicon nitride cantilevers as near-field optical probes offers the possibility to combine the two methods. Vertical forces and torsion are detected

  13. Optical diffraction tomography microscopy with transport of intensity equation using a light-emitting diode array

    Science.gov (United States)

    Li, Jiaji; Chen, Qian; Zhang, Jialin; Zhang, Zhao; Zhang, Yan; Zuo, Chao

    2017-08-01

    Optical diffraction tomography (ODT) is an effective label-free technique for quantitatively refractive index imaging, which enables long-term monitoring of the internal three-dimensional (3D) structures and molecular composition of biological cells with minimal perturbation. However, existing optical tomographic methods generally rely on interferometric configuration for phase measurement and sophisticated mechanical systems for sample rotation or beam scanning. Thereby, the measurement is suspect to phase error coming from the coherent speckle, environmental vibrations, and mechanical error during data acquisition process. To overcome these limitations, we present a new ODT technique based on non-interferometric phase retrieval and programmable illumination emitting from a light-emitting diode (LED) array. The experimental system is built based on a traditional bright field microscope, with the light source replaced by a programmable LED array, which provides angle-variable quasi-monochromatic illumination with an angular coverage of ±37 degrees in both x and y directions (corresponding to an illumination numerical aperture of ∼0.6). Transport of intensity equation (TIE) is utilized to recover the phase at different illumination angles, and the refractive index distribution is reconstructed based on the ODT framework under first Rytov approximation. The missing-cone problem in ODT is addressed by using the iterative non-negative constraint algorithm, and the misalignment of the LED array is further numerically corrected to improve the accuracy of refractive index quantification. Experiments on polystyrene beads and thick biological specimens show that the proposed approach allows accurate refractive index reconstruction while greatly reduced the system complexity and environmental sensitivity compared to conventional interferometric ODT approaches.

  14. Computational diffraction tomographic microscopy with transport of intensity equation using a light-emitting diode array

    Science.gov (United States)

    Li, Jiaji; Chen, Qian; Zhang, Jialin; Zuo, Chao

    2017-10-01

    Optical diffraction tomography (ODT) is an effective label-free technique for quantitatively refractive index imaging, which enables long-term monitoring of the internal three-dimensional (3D) structures and molecular composition of biological cells with minimal perturbation. However, existing optical tomographic methods generally rely on interferometric configuration for phase measurement and sophisticated mechanical systems for sample rotation or beam scanning. Thereby, the measurement is suspect to phase error coming from the coherent speckle, environmental vibrations, and mechanical error during data acquisition process. To overcome these limitations, we present a new ODT technique based on non-interferometric phase retrieval and programmable illumination emitting from a light-emitting diode (LED) array. The experimental system is built based on a traditional bright field microscope, with the light source replaced by a programmable LED array, which provides angle-variable quasi-monochromatic illumination with an angular coverage of +/-37 degrees in both x and y directions (corresponding to an illumination numerical aperture of ˜ 0.6). Transport of intensity equation (TIE) is utilized to recover the phase at different illumination angles, and the refractive index distribution is reconstructed based on the ODT framework under first Rytov approximation. The missing-cone problem in ODT is addressed by using the iterative non-negative constraint algorithm, and the misalignment of the LED array is further numerically corrected to improve the accuracy of refractive index quantification. Experiments on polystyrene beads and thick biological specimens show that the proposed approach allows accurate refractive index reconstruction while greatly reduced the system complexity and environmental sensitivity compared to conventional interferometric ODT approaches.

  15. Center of Excellence: Microlaser microscope. Annual progress technical report

    Energy Technology Data Exchange (ETDEWEB)

    Webb, R.H.

    1993-09-01

    This Center-of-Excellence grant has two components: Development of an imaging, system based on microlaser arrays forms a central project among a group of laser diagnostic and therapeutic efforts primarily funded outside the grant. In year 2 we have dealt with the slow delivery of new microlaser array approach to the idea of all-solid-state confocal microscopy. One solution was moderately successful, and another has produced the first microscope that is electronically switchable from confocal to non-confocal. We think this may be a useful alternative to the final design. This report thus discloses patentable material. We describe first the central Microlaser Microscope project, then we will tough briefly on the other projects of the Center. Publications are primarily those of the smaller projects, though no longer exclusively so. The appendix includes some of the publications.

  16. Simultaneous imaging of multiple focal planes in scanning two-photon absorption microscope by photon counting

    Science.gov (United States)

    Carriles, Ramón; Hoover, Erich E.; Amir, Wafa; Squier, Jeffery A.

    2007-09-01

    We demonstrate a two-photon absorption scanning microscope capable of imaging two focal planes simultaneously. The 23MHz fundamental laser is split in two, one part delayed in time while the other is focused with a deformable mirror to change its divergence. Both parts are then recombined to form a 46MHz pulse train consisting of two interlaced trains with different divergences that after the objective are focused at different sample depths. At the detection path, photon counting techniques allow photons coming from each depth to be separated based on their relative timing with respect to the 46MHz train. The separation is accomplished using a field-programmable gate array that has been programmed to switch back and forth between two counters at a rate provided by a master clock generated by the 46MHz pulse train. The computer that controls the scanners reads and resets the counters before moving to a new pixel. The scheme is demonstrated for two depths but can be extended to a larger number, the ultimate limit being the fluorescence lifetime. This technique could also be implemented for second or third harmonic generation microscopy, in this case the ultimate achievable number of focal planes would be determined by the electronics speed.

  17. Progress report towards a digital mirror device based confocal microscopic system

    Science.gov (United States)

    Yi, Dingrong; Lin, Shunhua; Huang, Simian; Xie, Shaochuan

    2013-12-01

    It is widely believed that by using a digital mirror device (DMD) as the spatial light modulator (SLM) of a programmable array microcopy (PAM), it is possible to achieve a cost-effective alternative to expensive confocal imaging devices. During the past decade, the design of such a DMD based PAM instrument has been frequently reported to enhance resolution and contrast, convincing images with improved quality are rare to be seen. The concrete implementation of a DMD based PAM instrument needs to successfully resolve multiple issues such as the adverse effects caused by the tilt angle of the micro-mirrors from the base board, the registration between a micro mirror of the DMD and the image pixel of the photo-detector and so on. In this paper, we report the design of a middle body consisting of a DMD as an independent attachment to a conventional microscope to convert the latter into a confocal imaging system, in a similar way as a filter turret that is placed below the head and the objectives of a regular microscopy to convert it into a fluorescent microscopy. Images of real objects with improved contrast are provided to demonstrate the effectiveness of using a DMD as SLM to improve the contrast of a PAM instrument. Such a PAM instrument has many advantages compared to conventional laser-scanning confocal systems including lower costs and higher imaging speeds. In addition, it allows convenient dynamic adjustments between imaging quality and imaging speed.

  18. Infrared up-conversion microscope

    DEFF Research Database (Denmark)

    2014-01-01

    There is presented an up-conversion infrared microscope (110) arranged for imaging an associated object (130), wherein the up-conversion infrared microscope (110) comprises a non-linear crystal (120) arranged for up-conversion of infrared electromagnetic radiation, and wherein an objective optical...

  19. Astroparticle physics: the new ASPERA-2 programme

    CERN Multimedia

    2009-01-01

    On 7 July the ASPERA-2 programme funded by the European Commission was officially launched in Hamburg with the goal of creating a sustainable structure for the coordination of astroparticle physics in Europe. CERN, which is a participant in the programme, could play an important role in this respect. Artist’s impression of the CTA (Cherenkov Telescope Array). The CTA is one of the "Magnificent Seven", the seven large astroparticle physics infrastructures planned for the coming years. It is the next-generation facility destined to succeed the H.E.S.S. telescope in Namibia and the MAGIC telescope in the Canary Islands. (Credit ASPERA/G.Toma/A.Saftoiu). Following the success of ASPERA-1, the European network for astroparticle physics (see box), funding agency representatives gathered in Hamburg on 7 July 2009 for the official launch of ASPERA-2, a new three-year programme funded by the European Commission. Today the strategic roles of ...

  20. Modification Of Normal Microscope To Magneto-Optical Microscope

    Directory of Open Access Journals (Sweden)

    Nurazlin Ahmad

    2015-04-01

    Full Text Available Abstract The present work reports on the modification of polarizing microscope to a magnetic domain imaging microscope based on Faraday Effect. Sample used in this research is a ferromagnetic garnet BiTmNa3FeGa5O12. The halogen lamp in the microscope is replaced by helium-neon HeNe laser as a light source. To reduce the laser spatial coherent effect thin transparent plastics placed in the laser path. The plastics are rotated at certain velocity. Other factors to be considered are the plastic rotation velocity the laser intensity and the laser alignment. Typical magnetic domain pattern is obtained with the new system.

  1. Improved Scanners for Microscopic Hyperspectral Imaging

    Science.gov (United States)

    Mao, Chengye

    2009-01-01

    Improved scanners to be incorporated into hyperspectral microscope-based imaging systems have been invented. Heretofore, in microscopic imaging, including spectral imaging, it has been customary to either move the specimen relative to the optical assembly that includes the microscope or else move the entire assembly relative to the specimen. It becomes extremely difficult to control such scanning when submicron translation increments are required, because the high magnification of the microscope enlarges all movements in the specimen image on the focal plane. To overcome this difficulty, in a system based on this invention, no attempt would be made to move either the specimen or the optical assembly. Instead, an objective lens would be moved within the assembly so as to cause translation of the image at the focal plane: the effect would be equivalent to scanning in the focal plane. The upper part of the figure depicts a generic proposed microscope-based hyperspectral imaging system incorporating the invention. The optical assembly of this system would include an objective lens (normally, a microscope objective lens) and a charge-coupled-device (CCD) camera. The objective lens would be mounted on a servomotor-driven translation stage, which would be capable of moving the lens in precisely controlled increments, relative to the camera, parallel to the focal-plane scan axis. The output of the CCD camera would be digitized and fed to a frame grabber in a computer. The computer would store the frame-grabber output for subsequent viewing and/or processing of images. The computer would contain a position-control interface board, through which it would control the servomotor. There are several versions of the invention. An essential feature common to all versions is that the stationary optical subassembly containing the camera would also contain a spatial window, at the focal plane of the objective lens, that would pass only a selected portion of the image. In one version

  2. The head-mounted microscope.

    Science.gov (United States)

    Chen, Ting; Dailey, Seth H; Naze, Sawyer A; Jiang, Jack J

    2012-04-01

    Microsurgical equipment has greatly advanced since the inception of the microscope into the operating room. These advancements have allowed for superior surgical precision and better post-operative results. This study focuses on the use of the Leica HM500 head-mounted microscope for the operating phonosurgeon. The head-mounted microscope has an optical zoom from 2× to 9× and provides a working distance from 300 mm to 700 mm. The headpiece, with its articulated eyepieces, adjusts easily to head shape and circumference, and offers a focus function, which is either automatic or manually controlled. We performed five microlaryngoscopic operations utilizing the head-mounted microscope with successful results. By creating a more ergonomically favorable operating posture, a surgeon may be able to obtain greater precision and success in phonomicrosurgery. Phonomicrosurgery requires the precise manipulation of long-handled cantilevered instruments through the narrow bore of a laryngoscope. The head-mounted microscope shortens the working distance compared with a stand microscope, thereby increasing arm stability, which may improve surgical precision. Also, the head-mounted design permits flexibility in head position, enabling operator comfort, and delaying musculoskeletal fatigue. A head-mounted microscope decreases the working distance and provides better ergonomics in laryngoscopic microsurgery. These advances provide the potential to promote precision in phonomicrosurgery. Copyright © 2011 The American Laryngological, Rhinological, and Otological Society, Inc.

  3. Phased arrays '85

    Science.gov (United States)

    Stiglitz, M. R.

    1985-11-01

    The conference Phased Arrays '85 was held in Bedford, MA, on October 15-18, 1985. It is pointed out that the 15 years between the 1970 and 1985 conferences dedicated to phased array antennas have seen many technological advances. Attention is given to the principle of operation, monolithic phased arrays, active arrays of monopole elements, scan compensated active element patterns, microstrip arrays, time delay technologies for phased array systems, ferrite materials for mm-wave phase shifters, phase-only optimization of phased array excitation by B-quadratic programming, a nearly frequency-independent sidelobe suppression technique for phased arrays, and active impedance effects in low sidelobe and ultrawideband phased arrays.

  4. En Note om Programmering

    DEFF Research Database (Denmark)

    Nørmark, Kurt

    2012-01-01

    Denne note er en introduktion til programmering. Formålet er at give dig et indblik i hvad programmering egentlig er for noget. Jeg vil vise at programmering kan foregå på forskellige måder, og at der er mange forskellige udfordringer forbundet med at programmere. Noten vil ikke knytte sig til et...... bestemt programmeringssprog. Noten vil kunne supplere et egentlig undervisningsmateriale, der støtter dig i en bestemt form for programmering i et udvalgt programmeringssprog....

  5. Finnish bioenergy research programme

    Energy Technology Data Exchange (ETDEWEB)

    Asplund, D. [VTT Energy, Jyvaeskylae (Finland)

    1996-12-31

    Finland is a leading country in the use of biofuels and has excellent opportunities to increase the use of biofuels by up to 25-30 %. The Finnish Government has set an objective for the promotion of bioenergy. The aim is to increase the use of bioenergy by about 25 % from the present level by 2005, and the increment corresponds to 1.5 million tonnes of oil equivalent (toe) per year. The R and D work has been considered as an important factor to achieve this ambitious goal. Energy research was organised into a series of research programmes in 1988 in accordance with the proposal of Finnish Energy Research Committee. The object of the research programmes is to enhance research activities and to bundle individual projects together into larger research packages. The common target of the Finnish energy research programmes is to proceed from basic and applied research to product development and pilot operation, and after that to the first commercial applications, e.g. demonstrations. As the organisation of energy research to programmes has led to good results, the Finnish Ministry of Trade and Industry decided to go on with this practice by launching new six-year programmes in 1993-1998. One of these programmes is the Bioenergy Research Programme and the co-ordination of this programme is carried out by VTT Energy. Besides VTT Energy the Finnish Forest Research Institute, Work Efficiency Institute, Metsaeteho and University of Joensuu are participating in the programme 7 refs.

  6. Overview of the Microscope Objective

    Science.gov (United States)

    Niu, Ruijuan

    Microscopes are widely used in research and industry. The objective lens is the most significant part of the microscope. Some characteristics and different types of microscope objectives are discussed in this thesis. The markings on the objective indicate some main optical characteristics. However, it is not always possible to know the materials, the radius or the thickness of each surface in an objective lens and it is not easy to simulate an objective without this data. In this thesis, we build a first order model which can simulate a refractive microscope objective when the magnification and numerical aperture are known. The model contains a thin lens made by two standard surfaces and also simulates the principal planes. This model provides more accurate ray heights and it is aplanatic. Some design examples of an objective lens are also discussed in order to get a better understanding of design and optimization considerations.

  7. Microscopic examination of deteriorated concrete

    NARCIS (Netherlands)

    Nijland, T.G.; Larbi, J.A.

    2010-01-01

    Concrete petrography is the integrated microscopic and mesoscale (hand specimen size) investigation of hardened concrete, that can provide information on the composition of concrete, the original relationships between the concrete's various constituents, and any changes therein, whether as a result

  8. Magnetic Resonance Force Microscope Development

    Energy Technology Data Exchange (ETDEWEB)

    Hammel, P.C.; Zhang, Z.; Suh, B.J.; Roukes, M.L.; Midzor, M.; Wigen, P.E.; Childress, J.R.

    1999-06-03

    Our objectives were to develop the Magnetic Resonance Force Microscope (MRFM) into an instrument capable of scientific studies of buried structures in technologically and scientifically important electronic materials such as magnetic multilayer materials. This work resulted in the successful demonstration of MRFM-detected ferromagnetic resonance (FMR) as a microscopic characterization tool for thin magnetic films. Strong FMR spectra obtained from microscopic Co thin films (500 and 1000 angstroms thick and 40 x 200 microns in lateral extent) allowed us to observe variations in sample inhomogeneity and magnetic anisotropy field. We demonstrated lateral imaging in microscopic FMR for the first time using a novel approach employing a spatially selective local field generated by a small magnetically polarized spherical crystallite of yttrium iron garnet. These successful applications of the MRFM in materials studies provided the basis for our successful proposal to DOE/BES to employ the MRF M in studies of buried interfaces in magnetic materials.

  9. Microscopic Procedures for Plant Meiosis.

    Science.gov (United States)

    Braselton, James P.

    1997-01-01

    Describes laboratory techniques designed to familiarize students with meiosis and how microscopic preparations of meiosis are made. These techniques require the use of fresh or fixed flowers. Contains 18 references. (DDR)

  10. Scanning laser video camera/ microscope

    Science.gov (United States)

    Wang, C. P.; Bow, R. T.

    1984-10-01

    A laser scanning system capable of scanning at standard video rate has been developed. The scanning mirrors, circuit design and system performance, as well as its applications to video cameras and ultra-violet microscopes, are discussed.

  11. [MICROSCOPIC COLITIS: THE CLINICAL CASE].

    Science.gov (United States)

    Kulygina, Y A; Skalinskaya, M I; Ageeva, T A

    2015-01-01

    During past years incidence and prevalence of microscopic colitis (MC) have increased, that is possible caused to the improvement of knowledge of doctors about the disease. This article contain modern views on epidemiology, diagnostic and variant of microscopic colitis treatment. A typical clinical picture of MC in the form of recurrent a watery diarrhea, with the absence of pathologic changes at roentgenologic and endoscopic investigations is described with the example of a clinical case.

  12. Coupling in reflector arrays

    DEFF Research Database (Denmark)

    Appel-Hansen, Jørgen

    1968-01-01

    In order to reduce the space occupied by a reflector array, it is desirable to arrange the array antennas as close to each other as possible; however, in this case coupling between the array antennas will reduce the reflecting properties of the reflector array. The purpose of the present communic......In order to reduce the space occupied by a reflector array, it is desirable to arrange the array antennas as close to each other as possible; however, in this case coupling between the array antennas will reduce the reflecting properties of the reflector array. The purpose of the present...

  13. Dynamic array of dark optical traps

    DEFF Research Database (Denmark)

    Daria, V.R.; Rodrigo, P.J.; Glückstad, J.

    2004-01-01

    A dynamic array of dark optical traps is generated for simultaneous trapping and arbitrary manipulation of multiple low-index microstructures. The dynamic intensity patterns forming the dark optical trap arrays are generated using a nearly loss-less phase-to-intensity conversion of a phase......-encoded coherent light source. Two-dimensional input phase distributions corresponding to the trapping patterns are encoded using a computer-programmable spatial light modulator, enabling each trap to be shaped and moved arbitrarily within the plane of observation. We demonstrate the generation of multiple dark...

  14. Application of Field programmable Gate Array to Digital Signal ...

    African Journals Online (AJOL)

    FPGA) can be applied to digital signal processing problem to increase computational speed. The best algorithm for solving Digital Signal Processing Applications; Fast Fourier Transform (FFT) algorithm has shown significant speed improvement ...

  15. Development of morphological operators for field programmable gate arrays

    Energy Technology Data Exchange (ETDEWEB)

    Tickle, A J; Smith, J S; Wu, Q H [Department of Electrical Engineering and Electronics, University of Liverpool, Liverpool L69 3GJ (United Kingdom)

    2007-07-15

    In this paper, we'll investigate development of Morphological Operators (MOs) that won't require raw VHDL coding but using the DSP Builder development tool in Simulink to generate the code via a graphical block method which we can then use in a hardware description language (HDL) development software. We will show development of basic MOs used for both binary and greyscale imagery specifically erosion and dilation for both cases before moving on to develop the more advanced MOs using the basic ones previously developed as a reference point again for both binary and greyscale imagery and will hence look at opening, closing, openclose and closeopen filters in both cases as well as thinning and convex hull for binary. Testing will involve pixel by pixel simulations and whole image simulations to prove that the MOs developed work at both these levels. The testing will include Quartus II vector waveform pixel analysis, timing layouts, Simulink data-stream imagery and ModelSim analysis of produced code.

  16. Development of morphological operators for field programmable gate arrays

    Science.gov (United States)

    Tickle, A. J.; Smith, J. S.; Wu, Q. H.

    2007-07-01

    In this paper, we'll investigate development of Morphological Operators (MOs) that won't require raw VHDL coding but using the DSP Builder development tool in Simulink to generate the code via a graphical block method which we can then use in a hardware description language (HDL) development software. We will show development of basic MOs used for both binary and greyscale imagery specifically erosion and dilation for both cases before moving on to develop the more advanced MOs using the basic ones previously developed as a reference point again for both binary and greyscale imagery and will hence look at opening, closing, openclose and closeopen filters in both cases as well as thinning and convex hull for binary. Testing will involve pixel by pixel simulations and whole image simulations to prove that the MOs developed work at both these levels. The testing will include Quartus II vector waveform pixel analysis, timing layouts, Simulink data-stream imagery and ModelSim analysis of produced code.

  17. Field-Programmable Gate Array (FPGA) Emulation for Computer Architecture

    Science.gov (United States)

    2009-08-01

    instruction set computer DRAM dynamic random access memory DSP digital signal processor ECAD electronic computer aided design FAME FPGA...performance evaluation corporation VHDL very-high-speed hardware description language VLSI very large scale integration XUP Xilinx university program... VHDL naturally runs in parallel on an FPGA, while a program written in languages like C or Java naturally runs sequentially on a computer. Indeed, the

  18. Parametric Reliability of Space-Based Field Programmable Gate Arrays

    Science.gov (United States)

    2007-03-01

    0.02 +kt1 = -0.11 kt1l = 0 kt2 = 0.022 ute = -1.5 + ua1 = 4.31e-009 ub1 = 7.61e...ute = -1.5 + ua1 = 4.31e-009 ub1 = 7.61e-018 uc1 = -5.6e-011 prt = 0 +at = 33000 +fnoimod = 1...57 + ua1 = 4.31e-009 ub1 = 7.61e-018 uc1 = -5.6e-011 prt = 0 +at = 33000 +fnoimod = 1

  19. REHABILITATION PRACTICAL PROGRAMME

    Directory of Open Access Journals (Sweden)

    Suzana KRANJC JOLDIKJ

    Full Text Available Centre for Education and Rehabilitation of Physi­cally Handicapped Children and Adolescents Kamnik (Zavod za usposabljanje invalidne mlad­ine Kamnik; hereinafter: ZUIM perform verified or state-ap­proved programme the Rehabilitation practical pro­gramme. The programme is intended for all those young people, who have completed primary school education, but cannot continue regular schooling in secondary school pro­grammes. The programme con­sists of several equivalent parts: education, practical work, train­ing work, health, therapeutic, psychologi­cal, and other activities. For every beginner in the first month of education members of the operative team create an individualized programme, which in­cludes individualized school work, individualized training programme, and other expert activities. The programme can last for 6 years maximum, it can however be completed earlier, when the op­erative team feels the training is no longer neces­sary. Pro­gress of a young person is what matters the most, and if there is no progress, the training is brought to an end. Training of young people in the Rehabilitation practical programme is only the be­ginning. The country will have to start considering social enter­prises, which are found elsewhere in the world, for example in Scandinavian countries and in the USA.

  20. Microscope and method of use

    Science.gov (United States)

    Bongianni, Wayne L.

    1984-01-01

    A method and apparatus for electronically focusing and electronically scanning microscopic specimens are given. In the invention, visual images of even moving, living, opaque specimens can be acoustically obtained and viewed with virtually no time needed for processing (i.e., real time processing is used). And planar samples are not required. The specimens (if planar) need not be moved during scanning, although it will be desirable and possible to move or rotate nonplanar specimens (e.g., laser fusion targets) against the lens of the apparatus. No coupling fluid is needed, so specimens need not be wetted. A phase acoustic microscope is also made from the basic microscope components together with electronic mixers.

  1. Microscopic colitis: a concise review.

    Science.gov (United States)

    Zippi, M; Marcheggiano, A; Crispino, P; Occhigrossi, G; Severi, C

    2010-01-01

    Microscopic colitis is an increasingly common cause of chronic watery diarrhoea, and often a causes of abdominal pain of unknown origins. The increase of interest for this clinical entity is due to a misdiagnosis of any symptoms that have been frequently attributed to diarrhea-predominant irritable bowel syndrome, often for many years before diagnosis. Presumably, most estimates of incidence and prevalence understate the true frequency of microscopic colitis for this reason. The aim of this paper is to evaluate the importance of microscopic colitis as cause of chronic non bloody diarrhoea, on the basis of literature review. These kind of colitis are characterized by normal colonic mucosa at endoscopy or barium enema but with increased inflammation in colonic biopsies. Microscopic colitis consists of two main subtypes, collagenous colitis and lymphocytic colitis, distinguished by the presence of absence of a thickened subepithelial collagen band. Several models of pathogenesis has been proposed but no convincing mechanism has been identified, although is difficult to characterize this clinical entity as an independent phenomenon or a simple manifestation or related factors active to induce microscopic changing in the colonic mucosa. A rational approach to therapy does not exist and was conduct with several types of drugs after the exclusion of other causes, commonly characterized by this symptoms and the definitive histological assessment in the biopsies specimens. In the majority of cases this condition tends to follow a self-limited course but potentially can assume the characteristics of relapsing course with the necessity to a chronic therapy. Several long-term follow-up studies excluded a possible progression to neoplastic malignancies of microscopic colitis.

  2. Atomic force microscope featuring an integrated optical microscope

    NARCIS (Netherlands)

    Putman, C.A.J.; Putman, Constant A.J.; de Grooth, B.G.; van Hulst, N.F.; Greve, Jan

    1992-01-01

    The atomic force microscope (AFM) is used to image the surface of both conductors and nonconductors. Biological specimens constitute a large group of nonconductors. A disadvantage of most AFM's is the fact that relatively large areas of the sample surface have to be scanned to pinpoint a biological

  3. Development of a normal incidence multilayer, imaging X-ray microscope

    Science.gov (United States)

    Shealy, David L.; Hoover, Richard B.; Walker, Arthur B. C., Jr.; Barbee, Troy W., Jr.

    1989-01-01

    This paper describes the design, analysis, and fabrication of a normal-incidence multilayer 20x Schwarzschild imaging X-ray microscope. The microscope is being fabricated using much of the technology implemented in the Multispectral Solar Telescope Array. Results of diffraction analysis show that better than 400 A spatial resolution in the object plane up to a 1-mm field of view can be achieved with 125 A radiation. Other microscope systems for use in conjunction with X-ray telescopes are analyzed and designed.

  4. Integrated infrared array technology

    Science.gov (United States)

    Goebel, J. H.; Mccreight, C. R.

    1987-01-01

    An overview of integrated infrared (IR) array technology is presented. Although the array pixel formats are smaller, and the readout noise of IR arrays is larger than the corresponding values achieved with optical charge-coupled-device silicon technology, substantial progress is being made in IR technology. Both existing IR arrays and those being developed are described. Examples of astronomical images are given which illustrate the potential of integrated IR arrays for scientific investigations.

  5. Greek Teachers Programme 2015

    CERN Multimedia

    Hoch, Michael

    2015-01-01

    The 3rd edition of this year's Greek Teachers Programme was co-organized by CERN Education Group and the Hellenic Physical Society and took place from 8 to 12 November 2015. The programme targets physics high-school teachers from all over Greece. It aims to help teachers inspire the next generation of scientists and engineers by motivating their students to understand and appreciate how science works at the world's largest physics laboratory, whereby increasing their interest in pursuing studies in STEM fields in secondary and post-secondary education. 33 teachers took part in this programme which comprised lectures by Greek members of the CERN scientific community, with visits to experimental facilities, hands-on activities and dedicated sessions on effective and creative ways through which participants may bring physics, particle physics and CERN closer to their school classroom. In 2015, more than 100 teachers took part in the three editions of the Greek Teachers Programme.

  6. The VIDA programme

    DEFF Research Database (Denmark)

    Jensen, Bente; Iannone, Rosa Lisa

    This case study describes the VIDA programme (knowledge-based efforts for socially disadvantaged children in daycare), an innovative professional development programme for those working with 3-6-year-old children in Denmark. The case study is part of WP3’s work on ‘Professional Development: Impact...... and Innovation’ within the project ‘Curriculum Quality Analysis and Impact Review of European Education and Care’ (CARE). The programme at the centre of this case builds on theory drawn from research on child development, social disadvantage related to issues of social inequality, and research on organisational...... programme period (2010-2013) and beyond?; 2) What is the impact of the VIDA approach to professional development on i) educators’ practices regarding high quality ECEC (output), ii) child outcomes (outcome), and iii) improved practice at the municipal level (impact in a broader sense)?; and 3) Which factors...

  7. Elukestva õppe programm : Erasmus+

    Index Scriptorium Estoniae

    2014-01-01

    Erasmus+ programm liidab senised koostööprogrammid „Euroopa elukestva õppe programm“, „Euroopa Noored“ ning Euroopa komisjoni rahvusvahelised kõrgharidusprogrammid. Elukestva õppe programmi 2013 kokkuvõte

  8. SPIC Undergraduate Programme

    Indian Academy of Sciences (India)

    Home; Journals; Resonance – Journal of Science Education; Volume 3; Issue 12. SPIC Undergraduate Programme. P K Subrahmanyam. Information and Announcements Volume 3 Issue 12 December 1998 pp 108-110. Fulltext. Click here to view fulltext PDF. Permanent link:

  9. Motivation programmes of organizations

    OpenAIRE

    Pízová, Tereza

    2008-01-01

    The Bachelor Thesis "'Motivation Programmes of Organizations" focuses on an extremely important area within personnel management. Employee motivation is crucial to the effective operation of businesses. Motivation programmes assist in increasing and maintaining employee motivation and demonstrate an organization's interest in its employees. This piece is on one hand concerned with theoretical foundations of motivation, describing theories and concepts important to the area of human behaviour ...

  10. The Gold Standard Programme

    DEFF Research Database (Denmark)

    Neumann, Tim; Rasmussen, Mette; Ghith, Nermin

    2013-01-01

    To evaluate the real-life effect of an evidence-based Gold Standard Programme (GSP) for smoking cessation interventions in disadvantaged patients and to identify modifiable factors that consistently produce the highest abstinence rates.......To evaluate the real-life effect of an evidence-based Gold Standard Programme (GSP) for smoking cessation interventions in disadvantaged patients and to identify modifiable factors that consistently produce the highest abstinence rates....

  11. Calm child programme.

    Science.gov (United States)

    Gobrial, Ereny; Raghavan, Raghu

    2017-01-01

    Children with autism spectrum disorder (ASD) and intellectual disabilities (IDs) are more vulnerable to experiencing anxiety disorders. Parental involvement in intervention is crucial for successful management of the interventions in the population of people with ASDs. This article describes the design and evaluation of parenting programme for anxiety disorders in children and young people with ASD and ID. In phase 1 semi-structured interviews were conducted to explore management strategies for anxiety at home and in school settings. A total of 34 participants (14 parents, 20 teachers) participated in the interviews. A Delphi process was conducted with health professionals to develop consensus on appropriate anxiety interventions. In phase 2 the intervention programme was implemented by seven parents who also participated in focus group to evaluate the developed programme. A parental programme, calm child programme (CCP), was developed, implemented and evaluated. The evaluations show significant decrease in children's anxiety as a result of implementing the programme. This study contributes further evidence to parental involvement in interventions for children and young people with ASD and IDs. The CCP is a useful and cost-effective approach in enabling parents to provide anxiety interventions in a home setting.

  12. Programmable synaptic chip for electronic neural networks

    Science.gov (United States)

    Moopenn, A.; Langenbacher, H.; Thakoor, A. P.; Khanna, S. K.

    1988-01-01

    A binary synaptic matrix chip has been developed for electronic neural networks. The matrix chip contains a programmable 32X32 array of 'long channel' NMOSFET binary connection elements implemented in a 3-micron bulk CMOS process. Since the neurons are kept off-chip, the synaptic chip serves as a 'cascadable' building block for a multi-chip synaptic network as large as 512X512 in size. As an alternative to the programmable NMOSFET (long channel) connection elements, tailored thin film resistors are deposited, in series with FET switches, on some CMOS test chips, to obtain the weak synaptic connections. Although deposition and patterning of the resistors require additional processing steps, they promise substantial savings in silicon area. The performance of synaptic chip in a 32-neuron breadboard system in an associative memory test application is discussed.

  13. Reflectance confocal microscope for imaging oral tissues in vivo, potentially with line scanning as a low-cost approach for clinical use

    Science.gov (United States)

    Peterson, Gary; Abeytunge, Sanjeewa; Eastman, Zachary; Rajadhyaksha, Milind

    2012-02-01

    Reflectance confocal microscopy with a line scanning approach potentially offers a smaller, simpler and less expensive approach than traditional methods of point scanning for imaging in living tissues. With one moving mechanical element (galvanometric scanner), a linear array detector and off-the-shelf optics, we designed a compact (102x102x76mm) line scanning confocal reflectance microscope (LSCRM) for imaging human tissues in vivo in a clinical setting. Custom-designed electronics, based on field programmable gate array (FPGA) logic has been developed. With 405 nm illumination and a custom objective lens of numerical aperture 0.5, lateral resolution was measured to be 0.8 um (calculated 0.64 um). The calculated optical sectioning is 3.2 um. Preliminary imaging shows nuclear and cellular detail in human skin and oral epithelium in vivo. Blood flow is also visualized in the deeper connective tissue (lamina propria) in oral mucosa. Since a line is confocal only in one dimension (parallel) but not in the other, the detection is more sensitive to multiply scattered out of focus background noise than in the traditional point scanning configuration. Based on the results of our translational studies thus far, a simpler, smaller and lower-cost approach based on a LSCRM appears to be promising for clinical imaging.

  14. Microscopic cross sections: An utopia?

    Energy Technology Data Exchange (ETDEWEB)

    Hilaire, S. [CEA Bruyeres-le-Chatel, DIF 91 (France); Koning, A.J. [Nuclear Research and Consultancy Group, PO Box 25, 1755 ZG Petten (Netherlands); Goriely, S. [Institut d' Astronomie et d' Astrophysique, Universite Libre de Bruxelles, Campus de la Plaine, CP 226, 1050 Brussels (Belgium)

    2010-07-01

    The increasing need for cross sections far from the valley of stability poses a challenge for nuclear reaction models. So far, predictions of cross sections have relied on more or less phenomenological approaches, depending on parameters adjusted to available experimental data or deduced from systematical relations. While such predictions are expected to be reliable for nuclei not too far from the experimentally known regions, it is clearly preferable to use more fundamental approaches, based on sound physical bases, when dealing with very exotic nuclei. Thanks to the high computer power available today, all major ingredients required to model a nuclear reaction can now be (and have been) microscopically (or semi-microscopically) determined starting from the information provided by a nucleon-nucleon effective interaction. We have implemented all these microscopic ingredients in the TALYS nuclear reaction code, and we are now almost able to perform fully microscopic cross section calculations. The quality of these ingredients and the impact of using them instead of the usually adopted phenomenological parameters will be discussed. (authors)

  15. Curriculum Guidelines for Microscopic Anatomy.

    Science.gov (United States)

    Journal of Dental Education, 1993

    1993-01-01

    The American Association of Dental Schools' guidelines for curricula in microscopic anatomy offer an overview of the histology curriculum, note primary educational goals, outline specific content for general and oral histology, suggest prerequisites, and make recommendations for sequencing. Appropriate faculty and facilities are also suggested.…

  16. Phase sensitive scanning optical microscope

    Energy Technology Data Exchange (ETDEWEB)

    Jungerman, R.L.; Hobbs, P.C.D.; Kino, G.S.

    1984-10-15

    An electronically scanned optical microscope which quantitatively measures amplitude and phase is described. The system is insenstive to mechanical vibrations. The phase infromation makes it possible to measure surface height variations with an accuracy of better than 100 A and can also be used to improve the lateral resolution.

  17. Microscope sterility during spine surgery.

    Science.gov (United States)

    Bible, Jesse E; O'Neill, Kevin R; Crosby, Colin G; Schoenecker, Jonathan G; McGirt, Matthew J; Devin, Clinton J

    2012-04-01

    Prospective study. Assess the contamination rates of sterile microscope drapes after spine surgery. The use of the operating microscope has become more prevalent in certain spine procedures, providing superior magnification, visualization, and illumination of the operative field. However, it may represent an additional source of bacterial contamination and increase the risk of developing a postoperative infection. This study included 25 surgical spine cases performed by a single spine surgeon that required the use of the operative microscope. Sterile culture swabs were used to obtain samples from 7 defined locations on the microscope drape after its use during the operation. The undraped technician's console was sampled in each case as a positive control, and an additional 25 microscope drapes were swabbed immediately after they were applied to the microscope to obtain negative controls. Swab samples were assessed for bacterial growth on 5% sheep blood Columbia agar plates using a semiquantitative technique. No growth was observed on any of the 25 negative control drapes. In contrast, 100% of preoperative and 96% of postoperative positive controls demonstrated obvious contamination. In the postoperative group, all 7 sites of evaluation were found to be contaminated with rates of 12% to 44%. Four of the 7 evaluated locations were found to have significant contamination rates compared with negative controls, including the shafts of the optic eyepieces on the main surgeon side (24%, P = 0.022), "forehead" portion on both the main surgeon (24%, P = 0.022) and assistant sides (28%, P = 0.010), and "overhead" portion of the drape (44%, P = 0.0002). Bacterial contamination of the operative microscope was found to be significant after spine surgery. Contamination was more common around the optic eyepieces, likely due to inadvertent touching of unsterile portions. Similarly, all regions above the eyepieces also have a propensity for contamination because of unknown contact

  18. Nanoscale magnetic stirring bars for heterogeneous catalysis in microscopic systems.

    Science.gov (United States)

    Yang, Shuliang; Cao, Changyan; Sun, Yongbin; Huang, Peipei; Wei, Fangfang; Song, Weiguo

    2015-02-23

    Nanometer-sized magnetic stirring bars containing Pd nanoparticles (denoted as Fe3 O4 -NC-PZS-Pd) for heterogeneous catalysis in microscopic system were prepared through a facile two-step process. In the hydrogenation of styrene, Fe3 O4 -NC-PZS-Pd showed an activity similar to that of the commercial Pd/C catalyst, but much better stability. In microscopic catalytic systems, Fe3 O4 -NC-PZS-Pd can effectively stir the reaction solution within microdrops to accelerate mass transfer, and displays far better catalytic activity than the commercial Pd/C for the hydrogenation of methylene blue in an array of microdroplets. These results suggested that the Fe3 O4 -NC-PZS-Pd could be used as nanoscale stirring bars in nanoreactors. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  19. Automated dimensional analysis using a light-sectioning microscope

    Energy Technology Data Exchange (ETDEWEB)

    Loomis, J.; Lightman, A. [Dayton Univ., OH (United States); Poe, A.; Caldwell, R. [Mound, Miamisburg, OH (United States)

    1988-12-31

    A computer vision system has been integrated with a modified light-sectioning microscope for quality control and inspection of a machined part whose critical dimensions are 30 to 300 {mu}m. Height measurements were determined by analysis of the projected light-section line. Transverse measurements were made using the microscope in a traditional configuration with illumination from selected elements of an external LED ring array. The light section irradiance was under computer control to accommodate the spatial variations in surface reflectance whose dynamic range exceeded that of the vision system. Part features are located by the vision system. Edges and line centers are then measured to sub-pixel resolution with a gray-level analysis algorithm. This paper describes the design and operation of this system. Details of the measurement process and analysis algorithms are provided.

  20. AfricaArray seismological studies of the structure and evolution of the African continent

    CSIR Research Space (South Africa)

    Durrheim, RJ

    2013-10-01

    Full Text Available The AfricaArray programme seeks to build geoscience capacity and conduct research that supports development in Africa. This paper reports on investigations of the structure and evolution of the African continent that have been concluded since...

  1. The INTEGRAL Core Observing Programme

    DEFF Research Database (Denmark)

    Winkler, C.; Gehrels, N.; Lund, Niels

    1999-01-01

    The Core Programme of the INTEGRAL mission is defined as the portion of the scientific programme covering the guaranteed time observations for the INTEGRAL Science Working Team. This paper describes the current status of the Core Programme preparations and summarizes the key elements...... of the observing programme....

  2. 21 CFR 884.6190 - Assisted reproductive microscopes and microscope accessories.

    Science.gov (United States)

    2010-04-01

    ... HUMAN SERVICES (CONTINUED) MEDICAL DEVICES OBSTETRICAL AND GYNECOLOGICAL DEVICES Assisted Reproduction.... Assisted reproduction microscopes and microscope accessories (excluding microscope stage warmers, which are classified under assisted reproduction accessories) are optical instruments used to enlarge images of gametes...

  3. Microscope Project for Undergraduate Laboratories

    CERN Document Server

    Chippendale, Rachel Kemp Alexander; Shumway, Jennifer; Tan, Amanda; Zuraw, Sarah; Ross, Jennifer L

    2016-01-01

    Optics is an important subfield of physics required for instrument design and used in a variety of other disciplines, including materials science, physics, and life sciences such as developmental biology and cell biology. It is important to educate students from a variety of disciplines and backgrounds in the basics of optics in order to train the next generation of interdisciplinary researchers and instrumentalists who will push the boundaries of discovery. In this paper, we present an experimental system developed to teach students in the basics of geometric optics, including ray and wave optics. The students learn these concepts through designing, building, and testing a home-built light microscope made from component parts. We describe the experimental equipment and basic measurements students can perform to learn principles, technique, accuracy, and resolution of measurement. Students find the magnification and test the resolution of the microscope system they build. The system is open and versatile to a...

  4. Microscopic colitis: a therapeutic challenge.

    Science.gov (United States)

    Guslandi, Mario

    2013-06-21

    The treatment of microscopic colitis is mainly based on the use of budesonide, the only drug found effective in controlled clinical trials. After an initial course at a dose of 9 mg daily, however, most patients relapse when the drug is discontinued, hence a maintenance therapy at doses of 6 mg daily or lower is necessary. In order to avoid steroid dependence and drug toxicity different pharmacological agents should be considered as an alternative to indefinite long-term budesonide treatment. Evidence-based guidelines are currently lacking due to the lack of conclusive data concerning the use of either immunosuppressive or anti-tumor necrosis factor agents. For the time being in clinical practice the skilled physician should therefore tailor long term management of microscopic colitis on the single patient.

  5. External Mobility Programme

    CERN Multimedia

    HR Department

    2007-01-01

    Every year, a significant number of highly-skilled staff members leave the Organization and offer their talents on the European job market. CERN is launching a programme aiming to help staff members to whom the Organization cannot offer an indefinite contract in the transition towards their next employment. The programme, which is based on the establishment of a number of partnerships with potential employers in the private sector, will run on a voluntary basis. Staff members who have received confirmation that they will not be offered an indefinite contract and who are interested in availing themselves of the opportunities offered by the programme, are invited to enrol by following the procedure described at: https://ert.cern.ch/browse_intranet/wd_pds?p_web_page_id=5841 Applications will be processed in the strictest confidence by the Human Resources Department and eligible profiles will then be made available to partner companies for recruitment purposes. Any subsequent ...

  6. Duties to Extraterrestrial Microscopic Organisms

    Science.gov (United States)

    Cockell, C. S.

    Formulating a normative axiology for the treatment of extraterrestrial microscopic organisms, should they ever be found, requires an extension of environmental ethics to beyond the Earth. Using an ethical framework for the treatment of terrestrial micro-organisms, this paper elaborates a similar ethic for the treatment of extraterrestrial microscopic organisms. An ethic of `teloempathy' allows for the moral considerability of any organism that has `interests', based on rudimentary qualities of conativism, and therefore allows for an identical treatment of all life, related or not related to life on Earth. Although, according to this ethic, individual extraterrestrial microscopic organisms have a good of their own and even `rights', at this level the ethic can only be theoretical, allowing for the inevitable destruction of many individual organisms during the course of human exploratory missions, similarly to the daily destruction of microbes by humans on Earth. A holistic teloempathy, an operative ethic, not only provides a framework for human exploration, but it also has important implications for planetary protection and proposals to implement planetary-scale atmospheric alterations on other bodies. Even prior to the discovery of extraterrestrial life, or the discovery of a complete absence of such life, this exercise yields important insights into the moral philosophy that guides our treatment of terrestrial micro-organisms.

  7. Axiom turkey genotyping array

    Science.gov (United States)

    The Axiom®Turkey Genotyping Array interrogates 643,845 probesets on the array, covering 643,845 SNPs. The array development was led by Dr. Julie Long of the USDA-ARS Beltsville Agricultural Research Center under a public-private partnership with Hendrix Genetics, Aviagen, and Affymetrix. The Turk...

  8. Clocked combustor can array

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Won-Wook; McMahan, Kevin Weston; Srinivasan, Shiva Kumar

    2017-01-17

    The present application provides a clocked combustor can array for coherence reduction in a gas turbine engine. The clocked combustor can array may include a number of combustor cans positioned in a circumferential array. A first set of the combustor cans may have a first orientation and a second set of the combustor cans may have a second orientation.

  9. Computer mathematics for programmers

    CERN Document Server

    Abney, Darrell H; Sibrel, Donald W

    1985-01-01

    Computer Mathematics for Programmers presents the Mathematics that is essential to the computer programmer.The book is comprised of 10 chapters. The first chapter introduces several computer number systems. Chapter 2 shows how to perform arithmetic operations using the number systems introduced in Chapter 1. The third chapter covers the way numbers are stored in computers, how the computer performs arithmetic on real numbers and integers, and how round-off errors are generated in computer programs. Chapter 4 details the use of algorithms and flowcharting as problem-solving tools for computer p

  10. Air Quality Monitoring Programme

    DEFF Research Database (Denmark)

    Kemp, K.; Palmgren, F.

    The Danish Air Quality Monitoring Programme (LMP IV) has been revised in accordance with the Framework Directive and the first three daughter directives of SO2, NOx/NO2, PM10, lead, benzene, CO and ozone. PM10 samplers are under installation and the installation will be completed during 2002....... The PM10 results from 2000 are spares, only TSP are thus included in this report. The data sets for year 2000 is complete for many stations. The monitoring programme consists of 10 stations plus 2 extra stations under the Municipality of Copenhagen. The SO2 and lead levels are still decreasing and far...

  11. Literature survey on microscopic friction modeling

    NARCIS (Netherlands)

    Hol, J.

    2010-01-01

    To better understand contact and friction conditions, experimental and theoretical studies have been performed in order to take microscopic dependencies into account. Friction is developed on microscopic level by adhesion between contacting asperities, the ploughing effect between asperities and the

  12. Thermophotovoltaic Array Optimization

    Energy Technology Data Exchange (ETDEWEB)

    SBurger; E Brown; K Rahner; L Danielson; J Openlander; J Vell; D Siganporia

    2004-07-29

    A systematic approach to thermophotovoltaic (TPV) array design and fabrication was used to optimize the performance of a 192-cell TPV array. The systematic approach began with cell selection criteria that ranked cells and then matched cell characteristics to maximize power output. Following cell selection, optimization continued with an array packaging design and fabrication techniques that introduced negligible electrical interconnect resistance and minimal parasitic losses while maintaining original cell electrical performance. This paper describes the cell selection and packaging aspects of array optimization as applied to fabrication of a 192-cell array.

  13. Computer Programmer/Analyst.

    Science.gov (United States)

    Ohio State Univ., Columbus. Center on Education and Training for Employment.

    This publication contains 25 subjects appropriate for use in a competency list for the occupation of computer programmer/analyst, 1 of 12 occupations within the business/computer technologies cluster. Each unit consists of a number of competencies; a list of competency builders is provided for each competency. Titles of the 25 units are as…

  14. En model for programmer

    DEFF Research Database (Denmark)

    Christensen, Henrik Bærbak

    Dette undervisningsmateriale beskriver en model for, hvordan programmer er opbygget. Materialet er skrevet til brug i det gymnasiale forsøgsfag Informationsteknologi. Seneste version af dette undervisningsmateriale kan findes på http:// www.imhotep.dk. Tak til Elisabeth Husum for en kritisk...

  15. (ARV) treatment training programme

    African Journals Online (AJOL)

    Winnie

    successful ARV programme requires that all components of a functional management system be put in place for effective and efficient functioning.This would include logistics, human resources, financial planning, and monitoring and ..... which service recipients were surveyed on the quality of service delivery noted above.

  16. Progressive Retirement Programme

    CERN Multimedia

    HR Department

    2007-01-01

    Following discussion at the Standing Concertation Committee at its meeting on 30 January 2007, the Director-General has approved the extension of the Progressive Retirement Programme with effect from 1 April 2007 until 31 March 2008. Human Resources Department Tel. 74484/74128

  17. The European Programme Manager

    DEFF Research Database (Denmark)

    Larson, Anne; Bergman, E.; Ehlers, S.

    The publication is a result of a cooperation between organisations in six European countries with the aim to develop a common European education for programme managers. It contains of a description of the different elements of the education together with a number of case-studies from the counties...

  18. The ONTARGET trial programme

    DEFF Research Database (Denmark)

    Unger, Thomas; Kintscher, Ulrich; Kappert, Kai

    2009-01-01

    The ONTARGET trial programme tested the effects of the angiotensin AT1 receptor blocker (ARB), telmisartan, alone or in combination with the angiotensin converting enzyme (ACE) inhibitor, ramipril, in more than 25.000 patients at high cardiovascular risk including diabetes on a combined endpoint...

  19. The Productive Programmer

    CERN Document Server

    Ford, Neal

    2009-01-01

    Anyone who develops software for a living needs a proven way to produce it better, faster, and cheaper. The Productive Programmer offers critical timesaving and productivity tools that you can adopt right away, no matter what platform you use. Master developer Neal Ford details ten valuable practices that will help you elude common traps, improve your code, and become more valuable to your team.

  20. SET-Routes programme

    CERN Multimedia

    Marietta Schupp, EMBL Photolab

    2008-01-01

    Dr Sabine Hentze, specialist in human genetics, giving an Insight Lecture entitled "Human Genetics – Diagnostics, Indications and Ethical Issues" on 23 September 2008 at EMBL Heidelberg. Activities in a achool in Budapest during a visit of Angela Bekesi, Ambassadors for the SET-Routes programme.

  1. cardiovascular disease intervention programme

    African Journals Online (AJOL)

    Changes in smoking during a community-based cardiovascular disease intervention programme. The Coronary Risk Factor Study. H. J. STEENKAMP, P. L. JOOSTE, P. C. J. JORDAAN,. A. S. P. SWANEPOEL, J. E. ROSSOUW. Summary. A prospective anti-smoking clinical trial was conducted as part of a coronary risk factor ...

  2. A Student-Built Scanning Tunneling Microscope

    Science.gov (United States)

    Ekkens, Tom

    2015-01-01

    Many introductory and nanotechnology textbooks discuss the operation of various microscopes including atomic force (AFM), scanning tunneling (STM), and scanning electron microscopes (SEM). In a nanotechnology laboratory class, students frequently utilize microscopes to obtain data without a thought about the detailed operation of the tool itself.…

  3. Dynamic Adaptive Neural Network Arrays: A Neuromorphic Architecture

    Energy Technology Data Exchange (ETDEWEB)

    Disney, Adam [University of Tennessee (UT); Reynolds, John [University of Tennessee (UT)

    2015-01-01

    Dynamic Adaptive Neural Network Array (DANNA) is a neuromorphic hardware implementation. It differs from most other neuromorphic projects in that it allows for programmability of structure, and it is trained or designed using evolutionary optimization. This paper describes the DANNA structure, how DANNA is trained using evolutionary optimization, and an application of DANNA to a very simple classification task.

  4. Modelling plexcitons of periodic gold nanorod arrays with molecular components

    Science.gov (United States)

    Liu, B.; Yan, H.; Stosch, R.; Wolfram, B.; Bröring, M.; Bakin, A.; Schilling, M.; Lemmens, P.

    2017-05-01

    Plasmonic or exciton/plasmon (plexcitonic) systems are presently described based on electromagnetic models, ignoring the need for an improved microscopic understanding. This is based on the fact that a full quantum mechanical approach on a micrometer scale still represents a considerable challenge. In this paper we report on the experimental observation of plexcitons in 2D gold nanorod array systems coupled to dye molecules and we provide a description of the experimental data using a quantum model. We show that treating the collective behavior in the array as being represented by a single quasiparticle is a suitable approximation that offers the opportunity to avoid the complicated calculation of long-distance interactions between the individual nanoparticles of the plexcitonic, periodic system. This enables us to model the optical response of plasmons in nanostructured arrays in contact with quantum emitters and to derive microscopic informations. Our work provides a potential tool for the design of plexcitonic devices, which rely on periodic metallic nanostructures.

  5. Design of Circularly-Polarised, Crossed Drooping Dipole, Phased Array Antenna Using Genetic Algorithm Optimisation

    DEFF Research Database (Denmark)

    Larsen, Niels Vesterdal

    2007-01-01

    A printed drooping dipole array is designed and constructed. The design is based on a genetic algorithm optimisation procedure used in conjunction with the software programme AWAS. By optimising the array G/T for specific combinations of scan angles and frequencies an optimum design is obtained...

  6. Volumetric Light-field Encryption at the Microscopic Scale

    Science.gov (United States)

    Li, Haoyu; Guo, Changliang; Muniraj, Inbarasan; Schroeder, Bryce C.; Sheridan, John T.; Jia, Shu

    2017-01-01

    We report a light-field based method that allows the optical encryption of three-dimensional (3D) volumetric information at the microscopic scale in a single 2D light-field image. The system consists of a microlens array and an array of random phase/amplitude masks. The method utilizes a wave optics model to account for the dominant diffraction effect at this new scale, and the system point-spread function (PSF) serves as the key for encryption and decryption. We successfully developed and demonstrated a deconvolution algorithm to retrieve both spatially multiplexed discrete data and continuous volumetric data from 2D light-field images. Showing that the method is practical for data transmission and storage, we obtained a faithful reconstruction of the 3D volumetric information from a digital copy of the encrypted light-field image. The method represents a new level of optical encryption, paving the way for broad industrial and biomedical applications in processing and securing 3D data at the microscopic scale.

  7. Microscopically Based Nuclear Energy Functionals

    Science.gov (United States)

    Bogner, S. K.

    2009-05-01

    A major goal of the SciDAC project "Building a Universal Nuclear Energy Density Functional" is to develop next-generation nuclear energy density functionals that give controlled extrapolations away from stability with improved performance across the mass table. One strategy is to identify missing physics in phenomenological Skyrme functionals based on our understanding of the underlying internucleon interactions and microscopic many-body theory. In this contribution, I describe ongoing efforts to use the density matrix expansion of Negele and Vautherin to incorporate missing finite-range effects from the underlying two- and three-nucleon interactions into phenomenological Skyrme functionals.

  8. Superconducting Bolometer Array Architectures

    Science.gov (United States)

    Benford, Dominic J.; Chervenak, James A.; Irwin, Kent D.; Moseley, S. H., Jr.; Shafer, Richard A.; Staguhn, Johannes G.; Wollack, Ed

    2003-02-01

    The next generation of far-infrared and submillimeter instruments require large arrays of detectors containing thousands of elements. These arrays will necessarily be multiplexed, and superconducting bolometer arrays are the most promising present prospect for these detectors. We discuss our current research into superconducting bolometer array technologies, which has recently resulted in the first multiplexed detections of submillimeter light and the first multiplexed astronomical observations. Prototype arrays containing 512 pixels are in production using the Pop-Up Detector (PUD) architecture, which can be extended easily to 1000 pixel arrays. Planar arrays of close-packed bolometers are being developed for the GBT and for future space missions. For certain applications, such as a slewed far-infrared sky survey, feedhorn-coupling of a large sparsely-filled array of bolometers is desirable, and is being developed using photolithographic feedhorn arrays. Individual detectors have achieved a Noise Equivalent Power (NEP) of ~10-17 W/√Hz at 300mK, but several orders of magnitude improvement are required and can be reached with existing technology. The testing of such ultralow-background detectors will prove difficult, as this requires optical loading of below 1fW. Antenna-coupled bolometer designs have advantages for large format array designs at low powers due to their mode selectivity. We also present a design and preliminary results for an enhanced-dynamic-range transition edge sensor suitable for broadband ultralow-background detectors.

  9. Mammographic screening programmes in Europe

    DEFF Research Database (Denmark)

    Giordano, Livia; von Karsa, Lawrence; Tomatis, Mariano

    2012-01-01

    To summarize participation and coverage rates in population mammographic screening programmes for breast cancer in Europe.......To summarize participation and coverage rates in population mammographic screening programmes for breast cancer in Europe....

  10. Robotic autopositioning of the operating microscope.

    Science.gov (United States)

    Oppenlander, Mark E; Chowdhry, Shakeel A; Merkl, Brandon; Hattendorf, Guido M; Nakaji, Peter; Spetzler, Robert F

    2014-06-01

    Use of the operating microscope has become pervasive since its introduction to the neurosurgical world. Neuronavigation fused with the operating microscope has allowed accurate correlation of the focal point of the microscope and its location on the downloaded imaging study. However, the robotic ability of the Pentero microscope has not been utilized to orient the angle of the microscope or to change its focal length to hone in on a predefined target. To report a novel technology that allows automatic positioning of the operating microscope onto a set target and utilization of a planned trajectory, either determined with the StealthStation S7 by using preoperative imaging or intraoperatively with the microscope. By utilizing the current motorized capabilities of the Zeiss OPMI Pentero microscope, a robotic autopositioning feature was developed in collaboration with Surgical Technologies, Medtronic, Inc. (StealthStation S7). The system is currently being tested at the Barrow Neurological Institute. Three options were developed for automatically positioning the microscope: AutoLock Current Point, Align Parallel to Plan, and Point to Plan Target. These options allow the microscope to pivot around the lesion, hover in a set plane parallel to the determined trajectory, or rotate and point to a set target point, respectively. Integration of automatic microscope positioning into the operative workflow has potential to increase operative efficacy and safety. This technology is best suited for precise trajectories and entry points into deep-seated lesions.

  11. Modelling of the MICROSCOPE Mission

    Science.gov (United States)

    Bremer, Stefanie; List, Meike

    2010-03-01

    The French space mission MICROSCOPE aims at testing the Equivalence Principle (EP) up to an accuracy of 10-15. The experiment will be carried out on a satellite which is developed and produced within the CNES Myriade series. The measuring accuracy will be achieved by means of two high-precision capacitive differential accelerometers that are built by the French institute ONERA, see Touboul and Rodrigues (Class. Quantum Gravity 18:2487-2498, 2001). At ZARM, which is a member of the science team, the data evaluation process is prepared. Therefore, a comprehensive simulation of the real system including the science signal and all error sources is built for the development and testing of data reduction and data analysis algorithms to extract the EP violation signal. Currently, the ZARM Drag-Free simulator, a tool to support mission modelling, is adapted for the MICROSCOPE mission in order to simulate test mass and satellite dynamics. Models of environmental disturbances like solar radiation pressure are considered, also. Additionally, detailed modelling of the on-board capacitive sensors is done. The actual status of the mission modelling will be presented. Particularly, the modelling of disturbances forces will be discussed in detail.

  12. Microscopic colitis: A literature review

    Directory of Open Access Journals (Sweden)

    ANA PAULA HAMER SOUSA CLARA

    Full Text Available SUMMARY Microscopic colitis (MC refers to chronic inflammation of the colon which is characterized by histologic changes at the level of a radiologically and endoscopically normal mucosa. It is a common cause of chronic non-bloody diarrhea that occurs primarily in older individuals; however, there are few studies in the literature with strong scientific evidence compared to other inflammatory bowel diseases (IBD, which limits the knowledge of physicians and pathologists. This article aims to review the information on MC, describing diagnostic methods and drugs available for treatment. We conducted a search of the Pubmed database and CAPES Portal using the keywords “microscopic colitis”, “collagenous colitis”, “lymphocytic colitis”, and “review” for selection of articles published between 1996 and 2015 related to the topic. Based on the studies discussed in this review, we conclude that MC is a relatively new gastrointestinal disorder, most studies are incipient particularly with respect to pathophysiology and immunology, and budesonide is the best documented short-term treatment. However, further studies are needed to elucidate the best strategy for treatment in the long term.

  13. Microscopic colitis: A literature review.

    Science.gov (United States)

    Clara, Ana Paula Hamer Sousa; Magnago, Flávia Drago; Ferreira, Juliana Neves; Grillo, Thais Gagno

    2016-12-01

    Microscopic colitis (MC) refers to chronic inflammation of the colon which is characterized by histologic changes at the level of a radiologically and endoscopically normal mucosa. It is a common cause of chronic non-bloody diarrhea that occurs primarily in older individuals; however, there are few studies in the literature with strong scientific evidence compared to other inflammatory bowel diseases (IBD), which limits the knowledge of physicians and pathologists. This article aims to review the information on MC, describing diagnostic methods and drugs available for treatment. We conducted a search of the Pubmed database and CAPES Portal using the keywords "microscopic colitis", "collagenous colitis", "lymphocytic colitis", and "review" for selection of articles published between 1996 and 2015 related to the topic. Based on the studies discussed in this review, we conclude that MC is a relatively new gastrointestinal disorder, most studies are incipient particularly with respect to pathophysiology and immunology, and budesonide is the best documented short-term treatment. However, further studies are needed to elucidate the best strategy for treatment in the long term.

  14. Companies' requirements on graduates - programmers

    OpenAIRE

    Urx, Martin

    2009-01-01

    The thesis maps different types of programmers and what are demands on programmers from employees. It analysis both technical skills and also soft-skills and their importance when evaluating a programmer. The thesis also contains an analysis of IT education offered by selected universities and high schools. The data are gathered through questionnaires and their results are confronted with the study options.

  15. Full-frame, programmable hyperspectral imager

    Energy Technology Data Exchange (ETDEWEB)

    Love, Steven P.; Graff, David L.

    2017-07-25

    A programmable, many-band spectral imager based on addressable spatial light modulators (ASLMs), such as micro-mirror-, micro-shutter- or liquid-crystal arrays, is described. Capable of collecting at once, without scanning, a complete two-dimensional spatial image with ASLM spectral processing applied simultaneously to the entire image, the invention employs optical assemblies wherein light from all image points is forced to impinge at the same angle onto the dispersing element, eliminating interplay between spatial position and wavelength. This is achieved, as examples, using telecentric optics to image light at the required constant angle, or with micro-optical array structures, such as micro-lens- or capillary arrays, that aim the light on a pixel-by-pixel basis. Light of a given wavelength then emerges from the disperser at the same angle for all image points, is collected at a unique location for simultaneous manipulation by the ASLM, then recombined with other wavelengths to form a final spectrally-processed image.

  16. Carbon nanotube nanoelectrode arrays

    Science.gov (United States)

    Ren, Zhifeng; Lin, Yuehe; Yantasee, Wassana; Liu, Guodong; Lu, Fang; Tu, Yi

    2008-11-18

    The present invention relates to microelectode arrays (MEAs), and more particularly to carbon nanotube nanoelectrode arrays (CNT-NEAs) for chemical and biological sensing, and methods of use. A nanoelectrode array includes a carbon nanotube material comprising an array of substantially linear carbon nanotubes each having a proximal end and a distal end, the proximal end of the carbon nanotubes are attached to a catalyst substrate material so as to form the array with a pre-determined site density, wherein the carbon nanotubes are aligned with respect to one another within the array; an electrically insulating layer on the surface of the carbon nanotube material, whereby the distal end of the carbon nanotubes extend beyond the electrically insulating layer; a second adhesive electrically insulating layer on the surface of the electrically insulating layer, whereby the distal end of the carbon nanotubes extend beyond the second adhesive electrically insulating layer; and a metal wire attached to the catalyst substrate material.

  17. Pharmacovigilance programme of India

    Directory of Open Access Journals (Sweden)

    Kalaiselvan Vivekanandan

    2012-01-01

    Full Text Available The monitoring and reporting of adverse drug reactions (ADRs through pharmacovigilance is vital to patient safety and rational prescribing. In India, Central Drugs Standard Control Organization (CDSCO initiated Pharmacovigilance Programme of India (PvPI to report ADRs through ADRs monitoring centres in India. Indian Pharmacopoeia Commission (IPC is functioning as National Coordination Centre (NCC for PvPI. The ADRs are reported to NCC through VigiFlow by various centres are evaluated and committed to Uppsala Monitoring Centre, Sweden. The potential benefit of the PvPI is aimed to reducing or eliminating a harm of medicine. Continuous efforts of the healthcare professionals and the patients are expected to make this as one of the most successful and effective programmes. The present article updates the status and future plan of PvPI.

  18. The Mathematica programmer

    CERN Document Server

    Maeder, Roman E

    1994-01-01

    The Mathematica Programmer covers the fundamental programming paradigms and applications of programming languages. This book is organized into two parts encompassing 10 chapters. Part 1 begins with an overview of the programming paradigms. This part also treats abstract data types, polymorphism and message passing, object-oriented programming, and relational databases. Part 2 looks into the practical aspects of programming languages, including in lists and power series, fractal curves, and minimal surfaces.This book will prove useful to mathematicians and computer scientists.

  19. Punch card programmable microfluidics.

    Directory of Open Access Journals (Sweden)

    George Korir

    Full Text Available Small volume fluid handling in single and multiphase microfluidics provides a promising strategy for efficient bio-chemical assays, low-cost point-of-care diagnostics and new approaches to scientific discoveries. However multiple barriers exist towards low-cost field deployment of programmable microfluidics. Incorporating multiple pumps, mixers and discrete valve based control of nanoliter fluids and droplets in an integrated, programmable manner without additional required external components has remained elusive. Combining the idea of punch card programming with arbitrary fluid control, here we describe a self-contained, hand-crank powered, multiplex and robust programmable microfluidic platform. A paper tape encodes information as a series of punched holes. A mechanical reader/actuator reads these paper tapes and correspondingly executes operations onto a microfluidic chip coupled to the platform in a plug-and-play fashion. Enabled by the complexity of codes that can be represented by a series of holes in punched paper tapes, we demonstrate independent control of 15 on-chip pumps with enhanced mixing, normally-closed valves and a novel on-demand impact-based droplet generator. We demonstrate robustness of operation by encoding a string of characters representing the word "PUNCHCARD MICROFLUIDICS" using the droplet generator. Multiplexing is demonstrated by implementing an example colorimetric water quality assays for pH, ammonia, nitrite and nitrate content in different water samples. With its portable and robust design, low cost and ease-of-use, we envision punch card programmable microfluidics will bring complex control of microfluidic chips into field-based applications in low-resource settings and in the hands of children around the world.

  20. Programme driven music radio

    OpenAIRE

    Hayes, Conor; Cunningham, Padraig; Clerkin, Patrick; Grimaldi, Marco

    2002-01-01

    This paper describes the operation of and research behind a networked application for the delivery of personalised streams of music at Trinity College Dublin. Smart Radio is a web based client-server application that uses streaming audio technology and recommendation techniques to allow users build, manage and share music programmes. While it is generally acknowledged that music distribution over the web will dramatically change how the music industry operates, there are ...

  1. Dynamically Reconfigurable Microphone Arrays

    Science.gov (United States)

    2011-05-01

    Static + 2 Wireless Using only a standard computer sound card, a robot is limited to binaural inputs. Even when using wireless microphones, the audio...Abstract—Robotic sound localization has traditionally been restricted to either on-robot microphone arrays or embedded microphones in aware...a microphone array has a significant impact on the mathematics of sound source localization. Arrays, for instance, are commonly designed to

  2. A new video programme

    CERN Multimedia

    CERN video productions

    2011-01-01

    "What's new @ CERN?", a new monthly video programme, will be broadcast on the Monday of every month on webcast.cern.ch. Aimed at the general public, the programme will cover the latest CERN news, with guests and explanatory features. Tune in on Monday 3 October at 4 pm (CET) to see the programme in English, and then at 4:20 pm (CET) for the French version.   var flash_video_player=get_video_player_path(); insert_player_for_external('Video/Public/Movies/2011/CERN-MOVIE-2011-129/CERN-MOVIE-2011-129-0753-kbps-640x360-25-fps-audio-64-kbps-44-kHz-stereo', 'mms://mediastream.cern.ch/MediaArchive/Video/Public/Movies/2011/CERN-MOVIE-2011-129/CERN-MOVIE-2011-129-Multirate-200-to-753-kbps-640x360-25-fps.wmv', 'false', 480, 360, 'https://mediastream.cern.ch/MediaArchive/Video/Public/Movies/2011/CERN-MOVIE-2011-129/CERN-MOVIE-2011-129-posterframe-640x360-at-10-percent.jpg', '1383406', true, 'Video/Public/Movies/2011/CERN-MOVIE-2011-129/CERN-MOVIE-2011-129-0600-kbps-maxH-360-25-fps-...

  3. Rectenna array measurement results

    Science.gov (United States)

    Dickinson, R. M.

    1980-01-01

    The measured performance characteristics of a rectenna array are reviewed and compared to the performance of a single element. It is shown that the performance may be extrapolated from the individual element to that of the collection of elements. Techniques for current and voltage combining were demonstrated. The array performance as a function of various operating parameters is characterized and techniques for overvoltage protection and automatic fault clearing in the array demonstrated. A method for detecting failed elements also exists. Instrumentation for deriving performance effectiveness is described. Measured harmonic radiation patterns and fundamental frequency scattered patterns for a low level illumination rectenna array are presented.

  4. Integrated Avalanche Photodiode arrays

    Energy Technology Data Exchange (ETDEWEB)

    Harmon, Eric S.

    2017-04-18

    The present disclosure includes devices for detecting photons, including avalanche photon detectors, arrays of such detectors, and circuits including such arrays. In some aspects, the detectors and arrays include a virtual beveled edge mesa structure surrounded by resistive material damaged by ion implantation and having side wall profiles that taper inwardly towards the top of the mesa structures, or towards the direction from which the ion implantation occurred. Other aspects are directed to masking and multiple implantation and/or annealing steps. Furthermore, methods for fabricating and using such devices, circuits and arrays are disclosed.

  5. Integrated avalanche photodiode arrays

    Science.gov (United States)

    Harmon, Eric S.

    2015-07-07

    The present disclosure includes devices for detecting photons, including avalanche photon detectors, arrays of such detectors, and circuits including such arrays. In some aspects, the detectors and arrays include a virtual beveled edge mesa structure surrounded by resistive material damaged by ion implantation and having side wall profiles that taper inwardly towards the top of the mesa structures, or towards the direction from which the ion implantation occurred. Other aspects are directed to masking and multiple implantation and/or annealing steps. Furthermore, methods for fabricating and using such devices, circuits and arrays are disclosed.

  6. Microscopic dynamics of liquid hydrogen

    CERN Document Server

    Zoppi, M; Celli, M

    2001-01-01

    We have measured the almost-pure incoherent scattering function of liquid parahydrogen using neutron inelastic scattering. The experiment was carried out on TOSCA, a time-of-flight, inverse geometry, crystal analyser spectrometer, operating on the pulsed- neutron source ISIS (UK). Since the instrument kinematic region is close to a line in the (k, E)-plane, we have actually measured the projection of S/sub inc/(k, w) on this line. The measured cross- section gives a direct experimental access to the microscopic dynamic of the centre-of-mass motion of molecular hydrogen. The data have been analysed using the Gaussian approximation and have been compared with the results of a novel Quantum Mechanical Molecular Dynamics simulation technique. The results are encouraging, but claim for further developments of the theoretical approach, as well as for more extensive experimental data. (14 refs).

  7. Microscopic dynamics underlying anomalous diffusion

    Science.gov (United States)

    Kaniadakis, G.; Lapenta, G.

    2000-09-01

    The time-dependent Tsallis statistical distribution describing anomalous diffusion is usually obtained in the literature as the solution of a nonlinear Fokker-Planck (FP) equation [A.R. Plastino and A. Plastino, Physica A 222, 347 (1995)]. The scope of the present paper is twofold. First, we show that this distribution can be obtained also as a solution of the nonlinear porous media equation. Second, we prove that the time-dependent Tsallis distribution can be obtained also as a solution of a linear FP equation [G. Kaniadakis and P. Quarati, Physica A 237, 229 (1997)] with coefficients depending on the velocity, which describes a generalized Brownian motion. This linear FP equation is shown to arise from a microscopic dynamics governed by a standard Langevin equation in the presence of multiplicative noise.

  8. Scanning Quantum Cryogenic Atom Microscope

    Science.gov (United States)

    Yang, Fan; Kollár, Alicia J.; Taylor, Stephen F.; Turner, Richard W.; Lev, Benjamin L.

    2017-03-01

    Microscopic imaging of local magnetic fields provides a window into the organizing principles of complex and technologically relevant condensed-matter materials. However, a wide variety of intriguing strongly correlated and topologically nontrivial materials exhibit poorly understood phenomena outside the detection capability of state-of-the-art high-sensitivity high-resolution scanning probe magnetometers. We introduce a quantum-noise-limited scanning probe magnetometer that can operate from room-to-cryogenic temperatures with unprecedented dc-field sensitivity and micron-scale resolution. The Scanning Quantum Cryogenic Atom Microscope (SQCRAMscope) employs a magnetically levitated atomic Bose-Einstein condensate (BEC), thereby providing immunity to conductive and blackbody radiative heating. The SQCRAMscope has a field sensitivity of 1.4 nT per resolution-limited point (approximately 2 μ m ) or 6 nT /√{Hz } per point at its duty cycle. Compared to point-by-point sensors, the long length of the BEC provides a naturally parallel measurement, allowing one to measure nearly 100 points with an effective field sensitivity of 600 pT /√{Hz } for each point during the same time as a point-by-point scanner measures these points sequentially. Moreover, it has a noise floor of 300 pT and provides nearly 2 orders of magnitude improvement in magnetic flux sensitivity (down to 10-6 Φ0/√{Hz } ) over previous atomic probe magnetometers capable of scanning near samples. These capabilities are carefully benchmarked by imaging magnetic fields arising from microfabricated wire patterns in a system where samples may be scanned, cryogenically cooled, and easily exchanged. We anticipate the SQCRAMscope will provide charge-transport images at temperatures from room temperature to 4 K in unconventional superconductors and topologically nontrivial materials.

  9. Endoscopic versus microscopic stapes surgery.

    Science.gov (United States)

    Surmelioglu, Ozgur; Ozdemir, Suleyman; Tarkan, Ozgur; Tuncer, Ulku; Dagkiran, Muhammed; Cetik, Fikret

    2017-06-01

    The aim of this study to compare the outcomes and complications of endoscopic stapes surgery versus microscopic stapes surgery. This study involved patients who underwent stapedotomy at the Department of Otorhinolaryngology, Faculty of Medicine, Cukurova University between January 2012 and July 2014. The patients were divided into two groups. Patients in group I were operated with endoscope and patients in group II were operated with microscope. Pure tone audiometry was carried out in all patients preoperatively. Peroperative surgical findings, complications, and duration of surgery were noted and compared between the two groups. Air conduction and bone conduction thresholds were measured at frequencies of 500, 1000, 2000, and 4000Hz, and the mean (±SD) air-bone gap was noted. Mean preoperative air-bone gap was 36.9±6.8dB (23.3-50dB) in group I and 35.1±6dB (26.6-50dB) in group II. Mean postoperative air-bone gap was 9.3±7.1dB (0-30dB) in group I and 13.5±9.7dB (1.6-35dB) in group II. The difference in preoperative and postoperative air-bone gap between the two groups was statistically significant (p=0.023). Patients in group I did not complain of postoperative pain but this was felt in four patients in group II. The difference was statistically significant (p=0.045). Endoscopic stapes surgery has many benefits such as good visualization, and easy accessibility to the stapes, oval window niche, and facial nerve. Removal of the scutum and manipulation of the chorda tympani nerve are less frequent with the endoscopic technique. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  10. A fully programmable computing architecture for medical ultrasound machines.

    Science.gov (United States)

    Schneider, Fabio Kurt; Agarwal, Anup; Yoo, Yang Mo; Fukuoka, Tetsuya; Kim, Yongmin

    2010-03-01

    Application-specific ICs have been traditionally used to support the high computational and data rate requirements in medical ultrasound systems, particularly in receive beamforming. Utilizing the previously developed efficient front-end algorithms, in this paper, we present a simple programmable computing architecture, consisting of a field-programmable gate array (FPGA) and a digital signal processor (DSP), to support core ultrasound signal processing. It was found that 97.3% and 51.8% of the FPGA and DSP resources are, respectively, needed to support all the front-end and back-end processing for B-mode imaging with 64 channels and 120 scanlines per frame at 30 frames/s. These results indicate that this programmable architecture can meet the requirements of low- and medium-level ultrasound machines while providing a flexible platform for supporting the development and deployment of new algorithms and emerging clinical applications.

  11. Coded SQUID arrays

    NARCIS (Netherlands)

    Podt, M.; Weenink, J.; Weenink, J.; Flokstra, Jakob; Rogalla, Horst

    2001-01-01

    We report on a superconducting quantum interference device (SQUID) system to read out large arrays of cryogenic detectors. In order to reduce the number of SQUIDs required for an array of these detectors, we used code-division multiplexing. This simplifies the electronics because of a significantly

  12. Microfabricated ion trap array

    Science.gov (United States)

    Blain, Matthew G [Albuquerque, NM; Fleming, James G [Albuquerque, NM

    2006-12-26

    A microfabricated ion trap array, comprising a plurality of ion traps having an inner radius of order one micron, can be fabricated using surface micromachining techniques and materials known to the integrated circuits manufacturing and microelectromechanical systems industries. Micromachining methods enable batch fabrication, reduced manufacturing costs, dimensional and positional precision, and monolithic integration of massive arrays of ion traps with microscale ion generation and detection devices. Massive arraying enables the microscale ion traps to retain the resolution, sensitivity, and mass range advantages necessary for high chemical selectivity. The reduced electrode voltage enables integration of the microfabricated ion trap array with on-chip circuit-based rf operation and detection electronics (i.e., cell phone electronics). Therefore, the full performance advantages of the microfabricated ion trap array can be realized in truly field portable, handheld microanalysis systems.

  13. Virtual vitreoretinal surgery: validation of a training programme.

    Science.gov (United States)

    Vergmann, Anna Stage; Vestergaard, Anders Højslet; Grauslund, Jakob

    2017-02-01

    To test the validity of the eyesi surgical simulator as an assessment tool in a virtual reality vitreoretinal training programme. In collaboration with an experienced vitreoretinal surgeon, a virtual vitreoretinal training programme was composed on the eyesi surgical simulator, software version 2.9.2 (VRmagic GmbH, Manheim, Germany). It was completed twice by three groups: 20 medical students, ten residents of ophthalmology and five trained vitreoretinal surgeons. The programme contained six training modules: navigation level 2 (Nav2), forceps training level 5 (ForT5), bimanual training level 3 (BimT3), laser coagulation level 3 (LasC3), posterior hyaloid level 3 (PostH3) and internal limiting membrane peeling level 3 (ILMP3). The scores in each module were assessed from two to five different factors (tissue treatment, efficiency, target achievement, instrument handling and microscope handling), and it was possible to achieve 100 points in each module. At the final training session, the highest overall median score was found for the vitreoretinal surgeons (vitreoretinal surgeons: 434 points, residents: 394.5 points, medical students: 272.5 points, p training programme with validity for the eyesi surgical simulator as an assessment tool for overall score and for four of six vitreoretinal modules. These findings could potentially make the programme a useful tool in the training of future vitreoretinal surgeons. © 2016 Acta Ophthalmologica Scandinavica Foundation. Published by John Wiley & Sons Ltd.

  14. A piezoelectric goniometer inside a transmission electron microscope goniometer.

    Science.gov (United States)

    Guan, Wei; Lockwood, Aiden; Inkson, Beverley J; Möbus, Günter

    2011-10-01

    Piezoelectric nanoactuators, which can provide extremely stable and reproducible positioning, are rapidly becoming the dominant means for position control in transmission electron microscopy. Here we present a second-generation miniature goniometric nanomanipulation system, which is fully piezo-actuated with ultrafine step size for translation and rotation, programmable, and can be fitted inside a hollowed standard specimen holder for a transmission electron microscope (TEM). The movement range of this miniaturized drive is composed of seven degrees of freedom: three fine translational movements (X, Y, and Z axes), three coarse translational movements along all three axes, and one rotational movement around the X-axis with an integrated angular sensor providing absolute rotation feedback. The new piezoelectric system independently operates as a goniometer inside the TEM goniometer. In situ experiments, such as tomographic tilt without missing wedge and differential tilt between two specimens, are demonstrated.

  15. Calibrated atomic force microscope measurements of vickers hardness indentations and tip production and characterisation for scanning tunelling microscope

    DEFF Research Database (Denmark)

    Jensen, Carsten P.

    Calibrated atomic force microscope measurements of vickers hardness indentations and tip production and characterisation for scanning tunelling microscope......Calibrated atomic force microscope measurements of vickers hardness indentations and tip production and characterisation for scanning tunelling microscope...

  16. CASINDO Programme Summary Report

    Energy Technology Data Exchange (ETDEWEB)

    Van der Linden, N.; Smekens, K.; Bole-Rentel, T.; Saidi, R. [Unit ECN Policy Studies, Energy research Centre of the Netherlands ECN, Petten (Netherlands); Wijnker, M. [Eindhoven University of Technology TUE, Eindhoven (Netherlands); Kamphuis, E. [ETC Netherlands, Leusden (Netherlands); Winarno, Oetomo Tri [Institute of Technology, Bandung (Indonesia); Permana, Iman [Technical Education Development Centre, Bandung (Indonesia)

    2012-06-15

    The overall objective of the CASINDO programme is to establish a self-sustaining and self-developing structure at both the national and regional level to build and strengthen human capacity to enable the provinces of North Sumatra, Yogyakarta, Central Java, West Nusa Tenggara and Papua to formulate sound policies for renewable energy and energy efficiency and to develop and implement sustainable energy projects. CASINDO stands for Capacity development and strenghtening for energy policy formulation adn implementation of sustainable energy projects in Indonesia.

  17. PROGRAMMABLE AUTONOMOUS ROBOTS

    Directory of Open Access Journals (Sweden)

    Lucian PESTRITU

    2012-05-01

    Full Text Available This paper aims to present how technology has advanced in terms of programmable microcontrollers and how circuits can be equipped with complex software so they can to act on their own, becoming a so-called autonomous robot or agent. To illustrate this, the 3PI robot is used, which is faced with solving a problem by itself, namely: solving a maze on its own. To make this possible so we had to implement this robot with a computer algorithm that helps it to remember the route that it had just travelled and then find the shortest and fastest way to the destination point.

  18. Multilateral Interoperability Programme

    Directory of Open Access Journals (Sweden)

    L. Burita

    2009-12-01

    Full Text Available The Multilateral Interoperability Programme (MIP is a voluntary and independent activity in NATO environment by the participating nations and organizations. The MIP concept is based on data exchange in form of common exchange data model to achieve the international interoperability in command and control information systems (C2IS of the tactical units. The article describes the basis of the MIP organizations, structure, planning and testing processes. The core of the MIP solution is the Information Exchange Data Model (IEDM. The Czech Armed Forces (CAF MIP process implementation is mentioned. The MIP example is a part of university education process.

  19. Foldscope: Origami-based paper microscope

    CERN Document Server

    Cybulski, James; Prakash, Manu

    2014-01-01

    Here we describe an ultra-low-cost origami-based approach for large-scale manufacturing of microscopes, specifically demonstrating brightfield, darkfield, and fluorescence microscopes. Merging principles of optical design with origami enables high-volume fabrication of microscopes from 2D media. Flexure mechanisms created via folding enable a flat compact design. Structural loops in folded paper provide kinematic constraints as a means for passive self-alignment. This light, rugged instrument can survive harsh field conditions while providing a diversity of imaging capabilities, thus serving wide-ranging applications for cost-effective, portable microscopes in science and education.

  20. Foldscope: Origami-Based Paper Microscope

    Science.gov (United States)

    Cybulski, James S.; Clements, James; Prakash, Manu

    2014-01-01

    Here we describe an ultra-low-cost origami-based approach for large-scale manufacturing of microscopes, specifically demonstrating brightfield, darkfield, and fluorescence microscopes. Merging principles of optical design with origami enables high-volume fabrication of microscopes from 2D media. Flexure mechanisms created via folding enable a flat compact design. Structural loops in folded paper provide kinematic constraints as a means for passive self-alignment. This light, rugged instrument can survive harsh field conditions while providing a diversity of imaging capabilities, thus serving wide-ranging applications for cost-effective, portable microscopes in science and education. PMID:24940755

  1. Foldscope: origami-based paper microscope.

    Directory of Open Access Journals (Sweden)

    James S Cybulski

    Full Text Available Here we describe an ultra-low-cost origami-based approach for large-scale manufacturing of microscopes, specifically demonstrating brightfield, darkfield, and fluorescence microscopes. Merging principles of optical design with origami enables high-volume fabrication of microscopes from 2D media. Flexure mechanisms created via folding enable a flat compact design. Structural loops in folded paper provide kinematic constraints as a means for passive self-alignment. This light, rugged instrument can survive harsh field conditions while providing a diversity of imaging capabilities, thus serving wide-ranging applications for cost-effective, portable microscopes in science and education.

  2. Field Emission of ITO-Coated Vertically Aligned Nanowire Array.

    KAUST Repository

    Lee, Changhwa

    2010-04-29

    An indium tin oxide (ITO)-coated vertically aligned nanowire array is fabricated, and the field emission characteristics of the nanowire array are investigated. An array of vertically aligned nanowires is considered an ideal structure for a field emitter because of its parallel orientation to the applied electric field. In this letter, a vertically aligned nanowire array is fabricated by modified conventional UV lithography and coated with 0.1-μm-thick ITO. The turn-on electric field intensity is about 2.0 V/μm, and the field enhancement factor, β, is approximately 3,078 when the gap for field emission is 0.6 μm, as measured with a nanomanipulator in a scanning electron microscope.

  3. GaN Nanowire Arrays for High-Output Nanogenerators

    KAUST Repository

    Huang, Chi-Te

    2010-04-07

    Three-fold symmetrically distributed GaN nanowire (NW) arrays have been epitaxially grown on GaN/sapphire substrates. The GaN NW possesses a triangular cross section enclosed by (0001), (2112), and (2112) planes, and the angle between the GaN NW and the substrate surface is ∼62°. The GaN NW arrays produce negative output voltage pulses when scanned by a conductive atomic force microscope in contact mode. The average of piezoelectric output voltage was about -20 mV, while 5-10% of the NWs had piezoelectric output voltages exceeding -(0.15-0.35) V. The GaN NW arrays are highly stable and highly tolerate to moisture in the atmosphere. The GaN NW arrays demonstrate an outstanding potential to be utilized for piezoelectric energy generation with a performance probably better than that of ZnO NWs. © 2010 American Chemical Society.

  4. Resolution optimization of an off-axis lensless digital holographic microscope.

    Science.gov (United States)

    Serabyn, E; Liewer, K; Wallace, J K

    2018-01-01

    Microscopes aimed at detecting cellular life in extreme environments such as ocean-bearing solar system moons must provide high resolution in a compact, robust instrument. Here, we consider the resolution optimization of a compact off-axis lensless digital holographic microscope (DHM) that consists of a sample placed between an input point-source pair and a detector array. Two optimal high-resolution regimes are identified at opposite extremes-a low-magnification regime with the sample located near a small-pixel detector array, and a high-magnification regime with the sample near the input plane. In the former, resolution improves with smaller pixels, while in the latter, the effect of the finite pixel size is obviated, and the spatial resolution improves with detector array size. Using an off-axis lensless DHM with a 2 k×2 k array of 5.5 μm-pixels in the high-magnification regime, and standard aberration correction software, a resolution of ∼0.95  μm has been demonstrated, a factor of 5.8 smaller than the pixel size. Our analysis further suggests that with yet larger detector arrays, a lensless DHM should be capable of near wavelength-scale resolution.

  5. PREPARATION FOR RETIREMENT PROGRAMME

    CERN Multimedia

    Human Resources Division

    2001-01-01

    27 March 2001 from 2.00 p.m. to 5.30 p.m. 28 March 2001 from 2.00 p.m. to 5.30 p.m. 29 March 2001 from 2.00 p.m. to 5.30 p.m. 30 March 2001 from 2.00 p.m. to 4.45 p.m. Auditorium (Main Building) After the success of the preparation seminars held in recent years, it has been decided that the programme should continue. The forthcoming seminar has been prepared in close collaboration with the CERN Pensioners' Association. The programme will be organised over several half-day sessions. Once again this year, a special session will be devoted to the 10th revision of the Swiss state pension scheme, the 'AVS' (Assurance-Vieillesse et Survivants), and the consequences for international civil servants. A talk will be given by Mrs Danièle Siebold, Director of the Caisse Cantonale Genevoise de Compensation, aimed mainly at those residing in or intending to move to Switzerland, or who worked in Switzerland before joining CERN. To enable Mrs Siebold to respond to your concerns as effectively as possible, please ...

  6. Sensor array signal processing

    CERN Document Server

    Naidu, Prabhakar S

    2009-01-01

    Chapter One: An Overview of Wavefields 1.1 Types of Wavefields and the Governing Equations 1.2 Wavefield in open space 1.3 Wavefield in bounded space 1.4 Stochastic wavefield 1.5 Multipath propagation 1.6 Propagation through random medium 1.7 ExercisesChapter Two: Sensor Array Systems 2.1 Uniform linear array (ULA) 2.2 Planar array 2.3 Distributed sensor array 2.4 Broadband sensor array 2.5 Source and sensor arrays 2.6 Multi-component sensor array2.7 ExercisesChapter Three: Frequency Wavenumber Processing 3.1 Digital filters in the w-k domain 3.2 Mapping of 1D into 2D filters 3.3 Multichannel Wiener filters 3.4 Wiener filters for ULA and UCA 3.5 Predictive noise cancellation 3.6 Exercises Chapter Four: Source Localization: Frequency Wavenumber Spectrum4.1 Frequency wavenumber spectrum 4.2 Beamformation 4.3 Capon's w-k spectrum 4.4 Maximum entropy w-k spectrum 4.5 Doppler-Azimuth Processing4.6 ExercisesChapter Five: Source Localization: Subspace Methods 5.1 Subspace methods (Narrowband) 5.2 Subspace methods (B...

  7. A submillimeter VLBI array

    Energy Technology Data Exchange (ETDEWEB)

    Weintroub, Jonathan [Harvard-Smithsonian Center for Astrophysics, 60 Garden Street, Cambridge, MA (United States)], E-mail: jweintroub@cfa.harvard.edu

    2008-10-15

    A VLBI array operating at {lambda} 1.3 mm and 0.8 mm is being designed using existing submillimeter telescopes as ad-hoc stations. Initial three station {lambda} = 1.3 mm observations of SgrA* and other AGN have produced remarkable results, which are reported by Doeleman elsewhere in this proceedings. Future observations are planned with an enhanced array which has longer baselines, more stations, and greater sensitivity. At {lambda} = 0.8 mm and on the long baselines, the array will have about a 20 {mu}as angular resolution which equals the diameter of the event horizon of the massive black hole in SgrA*. Candidate single dish facilities include the Arizona Radio Observatory Submillimeter Telescope (SMT) in Arizona, the Caltech Submillimeter Observatory (CSO) and the James Clerk Maxwell telescope (JCMT) in Hawaii, the Large Millimeter Telescope (LMT) in Mexico, ASTE and APEX in Chile, and the IRAM 30 m in Spain; interferometers include the Submillimeter Array (SMA) in Hawaii, the Combined Array for Research in Millimeter-wave Astronomy (CARMA) in California, IRAM PdB Interferometer in France, and the Atacama Large Millimeter Array (ALMA) in Chile. I will discuss the techniques we have developed for phasing interferometric arrays to act as single VLBI station. A strategy for detection of short (10s) time-scale source variability using VLBI closure phase will be described.

  8. Low bone mass in microscopic colitis.

    Science.gov (United States)

    Lorinczy, Katalin; Lakatos, Gábor; Müllner, Katalin; Hritz, István; Lakatos, Péter László; Tulassay, Zsolt; Miheller, Pál

    2011-05-19

    Microscopic colitis presents with similar symptoms to classic inflammatory bowel diseases. Osteoporosis is a common complication of Crohn's disease but there are no data concerning bone metabolism in microscopic colitis. The aim of the present study was to evaluate bone density and metabolism in patients with microscopic colitis. Fourteen patients microscopic colitis were included in the study, and 28 healthy persons and 28 age and gender matched Crohn's disease patients were enrolled as controls. Bone mineral density was measured using dual x-ray absorptiometry at the lumbar spine, femoral neck and the radius. Serum bone formation and bone resorption markers (osteocalcin and beta-crosslaps, respectively) were measured using immunoassays. Low bone mass was measured in 57.14% patients with microscopic colitis. Bone mineral density at the femoral neck in patients suffering from microscopic colitis and Crohn's disease was lower than in healthy controls (0.852 ± 0.165 and 0.807 ± 0.136 vs. 1.056 ± 0.126 g/cm²; p microscopic colitis patients (0.565 ± 0.093 vs. 0.667 ± 0.072 g/cm²; p microscopic colitis and Crohn's disease patients than controls (417.714 ± 250.37 and 466.071 ± 249.96 vs. 264.75 ± 138.65 pg/ml; p microscopic colitis patients. Low bone mass is frequent in microscopic colitis, and alterations to bone metabolism are similar to those present in Crohn's disease. Therefore, microscopic colitis-associated osteopenia could be a significant problem in such patients.

  9. Hamiltonian mechanics limits microscopic engines

    Science.gov (United States)

    Anglin, James; Gilz, Lukas; Thesing, Eike

    2015-05-01

    We propose a definition of fully microscopic engines (micro-engines) in terms of pure mechanics, without reference to thermodynamics, equilibrium, or cycles imposed by external control, and without invoking ergodic theory. This definition is pragmatically based on the observation that what makes engines useful is energy transport across a large ratio of dynamical time scales. We then prove that classical and quantum mechanics set non-trivial limits-of different kinds-on how much of the energy that a micro-engine extracts from its fuel can be converted into work. Our results are not merely formal; they imply manageable design constraints on micro-engines. They also suggest the novel possibility that thermodynamics does not emerge from mechanics in macroscopic regimes, but rather represents the macroscopic limit of a generalized theory, valid on all scales, which governs the important phenomenon of energy transport across large time scale ratios. We propose experimental realizations of the dynamical mechanisms we identify, with trapped ions and in Bose-Einstein condensates (``motorized bright solitons'').

  10. Mice embryology: a microscopic overview.

    Science.gov (United States)

    Salvadori, Maria Letícia Baptista; Lessa, Thais Borges; Russo, Fabiele Baldino; Fernandes, Renata Avancini; Kfoury, José Roberto; Braga, Patricia Cristina Baleeiro Beltrão; Miglino, Maria Angélica

    2012-10-01

    In this work, we studied the embryology of mice of 12, 14, and 18 days of gestation by gross observation, light microscopy, and scanning electron microscopy. Grossly, the embryos of 12 days were observed in C-shaped region of the brain, eye pigmentation of the retina, first, second, and third pharyngeal arches gill pit nasal region on the fourth ventricle brain, cervical curvature, heart, liver, limb bud thoracic, spinal cord, tail, umbilical cord, and place of the mesonephric ridge. Microscopically, the liver, cardiovascular system and spinal cord were observed. In the embryo of 14 days, we observed structures that make up the liver and heart. At 18 days of gestation fetuses, it was noted the presence of eyes, mouth, and nose in the cephalic region, chest and pelvic region with the presence of well-developed limbs, umbilical cord, and placenta. Scanning electron microscopy in 18 days of gestation fetuses evidenced head, eyes closed eyelids, nose, vibrissae, forelimb, heart, lung, kidney, liver, small bowel, diaphragm, and part of the spine. The results obtained in this work describe the internal and external morphology of mice, provided by an integration of techniques and review of the morphological knowledge of the embryonic development of this species, as this animal is of great importance to scientific studies. Copyright © 2012 Wiley Periodicals, Inc.

  11. Spectral Interferometry with Electron Microscopes

    Science.gov (United States)

    Talebi, Nahid

    2016-09-01

    Interference patterns are not only a defining characteristic of waves, but also have several applications; characterization of coherent processes and holography. Spatial holography with electron waves, has paved the way towards space-resolved characterization of magnetic domains and electrostatic potentials with angstrom spatial resolution. Another impetus in electron microscopy has been introduced by ultrafast electron microscopy which uses pulses of sub-picosecond durations for probing a laser induced excitation of the sample. However, attosecond temporal resolution has not yet been reported, merely due to the statistical distribution of arrival times of electrons at the sample, with respect to the laser time reference. This is however, the very time resolution which will be needed for performing time-frequency analysis. These difficulties are addressed here by proposing a new methodology to improve the synchronization between electron and optical excitations through introducing an efficient electron-driven photon source. We use focused transition radiation of the electron as a pump for the sample. Due to the nature of transition radiation, the process is coherent. This technique allows us to perform spectral interferometry with electron microscopes, with applications in retrieving the phase of electron-induced polarizations and reconstructing dynamics of the induced vector potential.

  12. High-speed multi-frame dynamic transmission electron microscope image acquisition system with arbitrary timing

    Energy Technology Data Exchange (ETDEWEB)

    Reed, Bryan W.; DeHope, William J.; Huete, Glenn; LaGrange, Thomas B.; Shuttlesworth, Richard M.

    2016-02-23

    An electron microscope is disclosed which has a laser-driven photocathode and an arbitrary waveform generator (AWG) laser system ("laser"). The laser produces a train of temporally-shaped laser pulses each being of a programmable pulse duration, and directs the laser pulses to the laser-driven photocathode to produce a train of electron pulses. An image sensor is used along with a deflector subsystem. The deflector subsystem is arranged downstream of the target but upstream of the image sensor, and has a plurality of plates. A control system having a digital sequencer controls the laser and a plurality of switching components, synchronized with the laser, to independently control excitation of each one of the deflector plates. This allows each electron pulse to be directed to a different portion of the image sensor, as well as to enable programmable pulse durations and programmable inter-pulse spacings.

  13. Piezoelectric transducer array microspeaker

    KAUST Repository

    Carreno, Armando Arpys Arevalo

    2016-12-19

    In this paper we present the fabrication and characterization of a piezoelectric micro-speaker. The speaker is an array of micro-machined piezoelectric membranes, fabricated on silicon wafer using advanced micro-machining techniques. Each array contains 2n piezoelectric transducer membranes, where “n” is the bit number. Every element of the array has a circular shape structure. The membrane is made out four layers: 300nm of platinum for the bottom electrode, 250nm or lead zirconate titanate (PZT), a top electrode of 300nm and a structural layer of 50

  14. Programmable pH buffers

    Science.gov (United States)

    Gough, Dara Van; Huber, Dale L.; Bunker, Bruce C.; Roberts, Mark E.

    2017-01-24

    A programmable pH buffer comprises a copolymer that changes pK.sub.a at a lower critical solution temperature (LCST) in water. The copolymer comprises a thermally programmable polymer that undergoes a hydrophobic-to-hydrophilic phase change at the LCST and an electrolytic polymer that exhibits acid-base properties that are responsive to the phase change. The programmable pH buffer can be used to sequester CO.sub.2 into water.

  15. Cigotica programme: pediatric experiences

    Directory of Open Access Journals (Sweden)

    Lešović Snežana

    2011-01-01

    Full Text Available Introduction The alarming spread of obesity epidemic in children and adolsecents, as well as the absence of tested and efficient measures and programmes on obesity preven­tion indicate the necessity for the establishment of the Centre for the prevention, treatment and rehabilitation of obesity in children and adolescents and the 'Cigotica Programme' at the Special Hospital 'Zlatibor'. The advantage of the 'Cigotica' Programme is the multidisciplinary approach to treating obese children, which implies specific education, dietetic interventions with the reduction in the total daily calorie intake, physical activity, medical, educational and psychological support, change of behavior and lifestyle. Objective To define obesity complications, metabolic risk factors and treatment effects on body composition and metabolic parameters in adolescents participating in the 'Cigotica' Programme. Method 1,030 adolescents were examined (498 girls and 532 boys, aged 12 to 18, average age 15.45, diagnosed with primary obesity, hospitalized at the Centre for the prevention, treatment and rehabilitation of obesity in children and adolescents at the Special Hospital 'Zlatibor', in the period from 27/07/2008 to 03/10/2010. Hospitalization lasted 21 days. Obesity criterion was body mass index (BMI > +2 SD . Body The Special Hospital for the Thyroid Gland and Metabolism Zlatibor mass, BMI, % of fat were obtained by means of Tanita scales for determining body composition using the impendence method. Apart from medical examination, blood pressure was also taken. The levels of triglycerides, total HDL and LDL cholesterols, uric acids and glycemia were determined on the second and twenty-first day of hospitalization after a 12-day fasting period. Results After the multidisciplinary treatment, the average reduction in body mass (p< 0.05 in all adolescents was 5.92 ± 2.71 kg, in boys - 6.24 ±3.24 kg, and in girls -5.86±2.4. During the 21-day hospitalization, the average

  16. Microscopic colitis : an unfamiliar but treatable disease

    NARCIS (Netherlands)

    van der Wouden, E. J.; Karrenbeld, A.; Kleibeuker, J. H.; Dijkstra, G.

    Chronic diarrhoea is a frequent complaint in clinical practice. Microscopic colitis is the cause of this symptom in 10% of these cases and the prevalence is rising. To exclude microscopic colitis a colonoscopy with multiple biopsies of different regions of the colon is mandatory. A sigmoidoscopy

  17. Scanning laser microscope for biological investigations.

    Science.gov (United States)

    Davidovits, P; Egger, M D

    1971-07-01

    The theory and design of a special purpose scanning laser microscope are described. This microscope, particularly suited for biological investigations, is intended for the observation of objects embedded within transparent or translucent bodies, such as nerve cells in an intact brain. Some photographs made with a prototype are shown.

  18. Polymerized LB Films Imaged with a Combined Atomic Force Microscope-Fluorescence Microscope

    NARCIS (Netherlands)

    Putman, C.A.J.; Putman, Constant A.J.; Hansma, Helen G.; Gaub, Hermann E.; Hansma, Paul K.

    1992-01-01

    The first results obtained with a new stand-alone atomic force microscope (AFM) integrated with a standard Zeiss optical fluorescence microscope are presented. The optical microscope allows location and selection of objects to be imaged with the high-resolution AFM. Furthermore, the combined

  19. A BLUEPRINT FOR MEASURING PROGRAMME OUTCOMES

    Directory of Open Access Journals (Sweden)

    SATESH NAMASIVAYAM

    2013-04-01

    Full Text Available Programme Outcomes (POs in the context of engineering education consists of a set of desired attributes which is to be possessed by an engineering graduate. POs are typically defined as a set of outcomes which is to be attained by an engineering graduate upon completion of the programme (or during graduation. In order to ascertain the attainment of the POs of an individual graduate, the engineering faculty can employ an array of methods to do so. Such methods are commonly placed in either quantitative or qualitative based analyses. In some cases, different types of analyses provide different results, which would render any form of discussion on PO attainment to its minimal. The present paper will highlight and discuss the important linkage of one quantitative and one qualitative method respectively employed to attain POs of an individual graduate. The result of the discussion would then be used to enhance the students overall understanding of the importance of the POs as well as to perform a self-reflection of how to address shortcomings based on POs which have not been attained.

  20. Programmable Ultra-Lightweight System Adaptable Radio

    Science.gov (United States)

    Werkheiser, Arthur

    2015-01-01

    The programmable ultra-lightweight system adaptable radio (PULSAR) is a NASA Marshall Space Flight Center transceiver designed for the CubeSat market, but has the potential for other markets. The PULSAR project aims to reduce size, weight, and power while increasing telemetry data rate. The current version of the PULSAR has a mass of 2.2 kg and a footprint of 10.8 cm2. The height depends on the specific configuration. The PULSAR S-Band Communications Subsystem is an S- and X-band transponder system comprised of a receiver/detector (receiver) element, a transmitter element(s), and related power distribution, command, control, and telemetry element for operation and information interfaces. It is capable of receiving commands, encoding and transmitting telemetry, as well as providing tracking data in a manner compatible with Earthbased ground stations, near Earth network, and deep space network station resources. The software-defined radio's (SDR's) data format characteristics can be defined and reconfigured during spaceflight or prior to launch. The PULSAR team continues to evolve the SDR to improve the performance and form factor to meet the requirements that the CubeSat market space requires. One of the unique features is that the actual radio design can change (somewhat), but not require any hardware modifications due to the use of field programmable gate arrays.

  1. Design of Infrasonic Arrays

    National Research Council Canada - National Science Library

    Blandford, Robert

    1997-01-01

    The Infrasound Experts Group of the Geneva Conference on Disarmament Ad Hoc Committee on a Nuclear Test Ban has recommended an infrasound array design consisting of four elements, with three elements...

  2. Expandable LED array interconnect

    Science.gov (United States)

    Yuan, Thomas Cheng-Hsin; Keller, Bernd

    2011-03-01

    A light emitting device that can function as an array element in an expandable array of such devices. The light emitting device comprises a substrate that has a top surface and a plurality of edges. Input and output terminals are mounted to the top surface of the substrate. Both terminals comprise a plurality of contact pads disposed proximate to the edges of the substrate, allowing for easy access to both terminals from multiple edges of the substrate. A lighting element is mounted to the top surface of the substrate. The lighting element is connected between the input and output terminals. The contact pads provide multiple access points to the terminals which allow for greater flexibility in design when the devices are used as array elements in an expandable array.

  3. The retinal readout array

    Science.gov (United States)

    Litke, Alan; Meister, Markus

    1991-12-01

    We have fabricated and tested a set of electrode arrays for the study of information processing in the retina. Live retinal tissue is placed on top of an array with the output neurons directly above the electrodes. Absorption of light by the photoreceptor cells leads to the generation of electrical pulses in the output neurons. These pulses, in turn, produce voltage signals on the electrodes which are recorded simultaneously by external electronics. Thus, for the first time, the spatial and temporal firing patterns of a large set of retinal nerve cells can be studied. The arrays are fabricated on quartz wafers coated with a transparent conducting layer of indium tin oxide. The electrodes are electroplated with platinum black. Polyimide is used for insulation. The fabrication and properties of these arrays, and illustrative results with retinal tissue, are described.

  4. Microscopic Colitis and Medication Use

    Directory of Open Access Journals (Sweden)

    Monina F. Pascua

    2010-01-01

    Full Text Available Background The incidence of microscopic colitis (MC is increasing, but its etiology remains unknown. Case reports and limited controlled data suggest that commonly prescribed drugs may be triggers. The aim of this study was to evaluate the prevalence of selected medication use [Proton pump inhibitors (PPIs, HMG-CoA reductase inhibitors (statins, and Selective serotonin reuptake inhibitors (SSRIs] in patients with MC compared to ‘random controls’ and ‘diarrhea controls.' Methods All patients were selected from primary care practices of a university health system during 2002 to 2007. Patients with biopsy proven lymphocytic or collagenous colitis were identified as cases. Diarrhea controls consisted of a 10:1 random sample of patients with chronic diarrhea and normal colon biopsies. Ten random controls were matched to each case on sex and index date (date of biopsy proven diagnosis. Drugs prescribed within the year prior to the index date were collected from the electronic medical record system. Results 26 cases (median age 68.9 yrs, 259 random, and 259 diarrhea controls were identified. The adjusted ORs for PPI, SSRI, and statin prescription within 12 months of diagnosis of MC between cases and diarrhea controls were 0.28 (0.07-1.07, 0.87 (0.28-2.64, 1.12 (0.34-3.71 respectively. Use of PPI and statins was less common in MC patients than in random controls ( P < 0.05 for both comparisons. Conclusions While prior data suggest that PPIs, statins, and SSRIs may be etiologically related to MC, our study found no increased association with these drugs.

  5. Programmable ferroelectric tunnel memristor

    Directory of Open Access Journals (Sweden)

    Andy eQuindeau

    2014-02-01

    Full Text Available We report an analogously programmable memristor based on genuine electronic resistive switching combining ferroelectric switching and electron tunneling. The tunnel current through an 8 unit cell thick epitaxial Pb(Zr[0.2]Ti[0.8]O[3] film sandwiched between La[0.7]Sr[0.3]MnO[3] and cobalt electrodes obeys the Kolmogorov-Avrami-Ishibashi model for bidimensional growth with a characteristic switching time in the order of 10^-7 seconds. The analytical description of switching kinetics allows us to develop a characteristic transfer function that has only one parameter viz. the characteristic switching time and fully predicts the resistive states of this type of memristor.

  6. Programmable Cadence Timer

    Science.gov (United States)

    Hall, William A.; Gilbert, John

    1990-01-01

    Electronic metronome paces users through wide range of exercise routines. Conceptual programmable cadence timer provides rhythmic aural and visual cues. Timer automatically changes cadence according to program entered by the user. It also functions as clock, stopwatch, or alarm. Modular pacer operated as single unit or as two units. With audiovisual module moved away from base module, user concentrates on exercise cues without distraction from information appearing on the liquid-crystal display. Variety of uses in rehabilitative medicine, experimental medicine, sports, and gymnastics. Used in intermittent positive-pressure breathing treatment, in which patient must rhythmically inhale and retain medication delivered under positive pressure; and in incentive spirometer treatment, in which patient must inhale maximally at regular intervals.

  7. Programmable multimode quantum networks

    Science.gov (United States)

    Armstrong, Seiji; Morizur, Jean-François; Janousek, Jiri; Hage, Boris; Treps, Nicolas; Lam, Ping Koy; Bachor, Hans-A.

    2012-08-01

    Entanglement between large numbers of quantum modes is the quintessential resource for future technologies such as the quantum internet. Conventionally, the generation of multimode entanglement in optics requires complex layouts of beamsplitters and phase shifters in order to transform the input modes into entangled modes. Here we report the highly versatile and efficient generation of various multimode entangled states with the ability to switch between different linear optics networks in real time. By defining our modes to be combinations of different spatial regions of one beam, we may use just one pair of multi-pixel detectors in order to measure multiple entangled modes. We programme virtual networks that are fully equivalent to the physical linear optics networks they are emulating. We present results for N=2 up to N=8 entangled modes here, including N=2, 3, 4 cluster states. Our approach introduces the highly sought after attributes of flexibility and scalability to multimode entanglement.

  8. Photovoltaic programme - edition 2003

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2003-07-01

    This publication issued by the Swiss Federal Office of Energy's Photovoltaics (PV) Programme presents an overview (in English) of activities and projects in the photovoltaics research and pilot and demonstration area in Switzerland. Progress in the area of future solar cell technologies, modules and building integration, system technologies, planning and operating aids is summarised. Also, PV for applications in developing countries, thermo-photovoltaics and international co-operation are commented on. In the area of pilot and demonstration projects, component development, PV integration in sloping roofs, on flat roofs and noise barriers as well as further PV plant are looked at. Also, measurement campaigns, studies, statistics and further PV-related topics are summarised. This volume also presents the abstracts of reports made by the project managers of 73 research and pilot and demonstration projects in these areas for 2002.

  9. Full-field interferometric confocal microscopy using a VCSEL array.

    Science.gov (United States)

    Redding, Brandon; Bromberg, Yaron; Choma, Michael A; Cao, Hui

    2014-08-01

    We present an interferometric confocal microscope using an array of 1200 vertical cavity surface emitting lasers (VCSELs) coupled to a multimode fiber. Spatial coherence gating provides ~18,000 continuous virtual pinholes, allowing an entire en face plane to be imaged in a snapshot. This approach maintains the same optical sectioning as a scanning confocal microscope without moving parts, while the high power of the VCSEL array (∼5  mW per laser) enables high-speed image acquisition with integration times as short as 100 μs. Interferometric detection also recovers the phase of the image, enabling quantitative phase measurements and improving the contrast when imaging phase objects.

  10. Development of programmable multi-channel earth resistivity system

    Energy Technology Data Exchange (ETDEWEB)

    Chung, Hyun Ki; Choi, Jong Ho; Park, In Wha [Korea Institute of Geology Mining and Materials, Taejon (Korea, Republic of)

    1996-12-01

    Maximum 256 channel digital-stacking automatic electrical earth resistivity meter is upgrade-developed and field-tested with two commercially available systems (OYO McOHM and ABEM Terrameter) for Schlumberger vertical sounding and dipole-dipole arrays. The results of three systems are very well coincident for several dummy resistors and Schlumberger array in field site. The developed system K-Ohm shows even more reasonable quality data in sensitive dipole-dipole array measurements in comparison with the electrical survey instruments of digital stacking type manufactured by other countries. New Important features of upgraded programmable K-Ohm system are as follows ; 1) Auto-electrode-switching control by Notebook printer port, 2) receiving signal measurement by Notebook serial port, 3) interactive automatic dipole-dipole measurement software with two apparent resistivity sections compared in one Notebook display to minimize noisy data in field, 4) auto-saved field memo at any time appending to acquired data, 5) max 500 V{sub p-p} 500 mA transmitter (measuring cycle S/W programmable), 6) low-drift sigma - delta 24 bit A/D 0.0015 % linearity error with zero-offset and full - scale gain autocalibration, 7) DC 12 v operated and TX-RX 7,000 V optical-isolated, 8) electrodes grounding auto-tested, user-oriented any array sequential programmable control software. Further study will be focused on higher power TX and stand alone TX-RX system, and micro-resistivity system for in-borehole resistivity imaging. (author). 8 refs., 9 figs.

  11. Soft x-ray microscope using Fourier transform holography

    Energy Technology Data Exchange (ETDEWEB)

    McNulty, I.; Kirz, J.; Jacobsen, C.; Anderson, E.; Howells, M.R.; Rarback, H. (State Univ. of New York, Stony Brook, NY (USA). Dept. of Physics; Lawrence Berkeley Lab., CA (USA); Brookhaven National Lab., Upton, NY (USA))

    1989-01-01

    A Fourier transform holographic microscope with an anticipated resolution of better than 100 nm has been built. Extensive testing of the apparatus has begun. Preliminary results include the recording of interference fringes using 3.6 nm x-rays. The microscope employs a charge-coupled device (CCD) detector array of 576 {times} 384 elements. The system is illuminated by soft x-rays from a high brightness undulator. The reference point source is formed by a Fresnel zone plate with a finest outer zone width of 50 nm. Sufficient temporal coherence for hologram formation is obtained by a spherical grating monochromator. The x-ray hologram intensities at the recording plane are to be collected, digitized and reconstructed by computer. Data acquisition is under CAMAC control, while image display and off-line processing takes place on a VAX graphics workstation. Computational models of Fourier transform hologram synthesis, and reconstruction in the presence of noise, have demonstrated the feasibility of numerical methods in two dimensions, and that three-dimensional information is potentially recoverable. 13 refs., 3 figs.

  12. An automatic bibliography indexing programme

    Directory of Open Access Journals (Sweden)

    J. W. Morris

    1974-12-01

    Full Text Available A relatively simple FORTRAN IV programme, designed for a small computer, for author and key-word indexes to bibliographic records is described, and examples of output are given. It is com­pared with some other systems. Suggested improvements to the programme are given.

  13. Climate Ambassador Programmes in Municipalities

    DEFF Research Database (Denmark)

    Jørgensen, Michael Søgaard; Pedersen, Stine Rahbek

    2016-01-01

    in the municipalities of Furesø, Lyngby-Taarbæk, Frederiksberg and Hvidovre. Two of the ambassador programmes presented here focus primarily on climate change mitigation initiatives, and two have a broader focus on sustainable development. Important elements for the impact of these programmes are the networking among...

  14. Undergraduate Programme: Admissions for 2013

    Indian Academy of Sciences (India)

    IAS Admin

    2013-02-01

    Feb 1, 2013 ... Undergraduate Programme: Admissions for 2013. The Indian Institute of Science, a leading institution of higher learning with a strong tradition of research, offers a four-year Bachelor of Science (B.S.) Programme which is designed as a balanced blend of core science and interdisciplinary topics to serve as ...

  15. Microfabricated Fountain Pens for High-Density DNA Arrays

    OpenAIRE

    Reese, Matthew O.; van Dam, R. Michae; Scherer, Axel; Quake, Stephen R.

    2003-01-01

    We used photolithographic microfabrication techniques to create very small stainless steel fountain pens that were installed in place of conventional pens on a microarray spotter. Because of the small feature size produced by the microfabricated pens, we were able to print arrays with up to 25,000 spots/cm2, significantly higher than can be achieved by other deposition methods. This feature density is sufficiently large that a standard microscope slide can contain multiple replicates of every...

  16. A BLUEPRINT FOR IMPLEMENTING GRAND CHALLENGE SCHOLARS’ PROGRAMME: A CASE STUDY OF TAYLOR’S UNIVERSITY

    Directory of Open Access Journals (Sweden)

    MUSHTAK AL-ATABI

    2013-04-01

    Full Text Available The National Academy for Engineering announced 14 Grand Challenges for the 21st Century engineers to address in order to ensure a sustainable future for the generations to come. These grand challenges are in four broad areas, namely, energy and environment, health, security and learning and computation. This paper reports on a Grand Challenges Scholars’ Programme that is developed to prepare the engineering students to be able to address the grand challenges using the CDIO framework and focusing on five components; research experience, interdisciplinary curriculum, entrepreneurship, global dimension and service learning. The programme is voluntary and the candidates are expected to commit additional learning time. The programme was launched with 16 participants who are expected to graduate in 2016. A preliminary assessment of the programs shows that the participants found the programme useful in developing an array of CDIO skills. The School intends to continue offering this programme with the intention of integrating it with a holistic education approach.

  17. Optically Sectioning Ocular Fluorometer Microscope: Applications To The Cornea

    Science.gov (United States)

    Masters, Barry R.

    1988-06-01

    An optically sectioning ocular fluorometer microscope is described with the capability of measuring the emission spectra of molecules in planes along the microscope axis. Its unique feature is that the objective is attached to a piezoelectric driver and scans from the tear film to the aqueous humor. This permits measurements on living animals and adoption for clinical use. The excitation light from a laser (nitrogen, dye, argon or helium cadmium) couples to the microscope via a quartz optical fiber. The light is projected through a 100 PM slit on the excitation side, through one half of the objective. The emitted light is collected by the second half of the objective and passes a second 100 pm slit in the conjugate plane of the eyepiece. The depth resolution is 6 um with an 100x objective, and 18 PM with a 50 power objective. The fluorescence is coupled by a quartz fiber to an optical spectrum analyzer. It consists of a monochromator with two microchannel plates attached to a linear diode array. The photocathode of the detector is gated for use with pulsed lasers or it can operate in the continuous mode. The applications include fluorescence measurements on thin layered structures. The present study involves the noninvasive measurement of oxidative metabolism of the component layers of the in vivo cornea. This is based on fluorescence measurements of the reduced pyridine nucleotide in the cornea. The fluorescence signals from the corneal epithelial (30 μm) and endothelial (4 μm) are clearly defined. Other applications to ophthalmology include studies of the fluorescence form the component layers of the ocular lens. Support from N.I.I. EY06958.

  18. Pupil engineering for a confocal reflectance line-scanning microscope

    Science.gov (United States)

    Patel, Yogesh G.; Rajadhyaksha, Milind; DiMarzio, Charles A.

    2011-03-01

    Confocal reflectance microscopy may enable screening and diagnosis of skin cancers noninvasively and in real-time, as an adjunct to biopsy and pathology. Current confocal point-scanning systems are large, complex, and expensive. A confocal line-scanning microscope, utilizing a of linear array detector can be simpler, smaller, less expensive, and may accelerate the translation of confocal microscopy in clinical and surgical dermatology. A line scanner may be implemented with a divided-pupil, half used for transmission and half for detection, or with a full-pupil using a beamsplitter. The premise is that a confocal line-scanner with either a divided-pupil or a full-pupil will provide high resolution and optical sectioning that would be competitive to that of the standard confocal point-scanner. We have developed a confocal line-scanner that combines both divided-pupil and full-pupil configurations. This combined-pupil prototype is being evaluated to determine the advantages and limitations of each configuration for imaging skin, and comparison of performance to that of commercially available standard confocal point-scanning microscopes. With the combined configuration, experimental evaluation of line spread functions (LSFs), contrast, signal-to-noise ratio, and imaging performance is in progress under identical optical and skin conditions. Experimental comparisons between divided-pupil and full-pupil LSFs will be used to determine imaging performance. Both results will be compared to theoretical calculations using our previously reported Fourier analysis model and to the confocal point spread function (PSF). These results may lead to a simpler class of confocal reflectance scanning microscopes for clinical and surgical dermatology.

  19. Javascript Library for Developing Interactive Micro-Level Animations for Teaching and Learning Algorithms on One-Dimensional Arrays

    Science.gov (United States)

    Végh, Ladislav

    2016-01-01

    The first data structure that first-year undergraduate students learn during the programming and algorithms courses is the one-dimensional array. For novice programmers, it might be hard to understand different algorithms on arrays (e.g. searching, mirroring, sorting algorithms), because the algorithms dynamically change the values of elements. In…

  20. Comparative study of image contrast in scanning electron microscope and helium ion microscope.

    Science.gov (United States)

    O'Connell, R; Chen, Y; Zhang, H; Zhou, Y; Fox, D; Maguire, P; Wang, J J; Rodenburg, C

    2017-12-01

    Images of Ga+ -implanted amorphous silicon layers in a 110 n-type silicon substrate have been collected by a range of detectors in a scanning electron microscope and a helium ion microscope. The effects of the implantation dose and imaging parameters (beam energy, dwell time, etc.) on the image contrast were investigated. We demonstrate a similar relationship for both the helium ion microscope Everhart-Thornley and scanning electron microscope Inlens detectors between the contrast of the images and the Ga+ density and imaging parameters. These results also show that dynamic charging effects have a significant impact on the quantification of the helium ion microscope and scanning electron microscope contrast. © 2017 The Authors Journal of Microscopy © 2017 Royal Microscopical Society.

  1. Atomic Force Microscope Mediated Chromatography

    Science.gov (United States)

    Anderson, Mark S.

    2013-01-01

    The atomic force microscope (AFM) is used to inject a sample, provide shear-driven liquid flow over a functionalized substrate, and detect separated components. This is demonstrated using lipophilic dyes and normal phase chromatography. A significant reduction in both size and separation time scales is achieved with a 25-micron-length column scale, and one-second separation times. The approach has general applications to trace chemical and microfluidic analysis. The AFM is now a common tool for ultra-microscopy and nanotechnology. It has also been demonstrated to provide a number of microfluidic functions necessary for miniaturized chromatography. These include injection of sub-femtoliter samples, fluidic switching, and sheardriven pumping. The AFM probe tip can be used to selectively remove surface layers for subsequent microchemical analysis using infrared and tip-enhanced Raman spectroscopy. With its ability to image individual atoms, the AFM is a remarkably sensitive detector that can be used to detect separated components. These diverse functional components of microfluidic manipulation have been combined in this work to demonstrate AFM mediated chromatography. AFM mediated chromatography uses channel-less, shear-driven pumping. This is demonstrated with a thin, aluminum oxide substrate and a non-polar solvent system to separate a mixture of lipophilic dyes. In conventional chromatographic terms, this is analogous to thin-layer chromatography using normal phase alumina substrate with sheardriven pumping provided by the AFM tip-cantilever mechanism. The AFM detection of separated components is accomplished by exploiting the variation in the localized friction of the separated components. The AFM tip-cantilever provides the mechanism for producing shear-induced flows and rapid pumping. Shear-driven chromatography (SDC) is a relatively new concept that overcomes the speed and miniaturization limitations of conventional liquid chromatography. SDC is based on a

  2. Programmable solid state atom sources for nanofabrication

    Science.gov (United States)

    Han, Han; Imboden, Matthias; Stark, Thomas; Del Corro, Pablo G.; Pardo, Flavio; Bolle, Cristian A.; Lally, Richard W.; Bishop, David J.

    2015-06-01

    In this paper we discuss the development of a MEMS-based solid state atom source that can provide controllable atom deposition ranging over eight orders of magnitude, from ten atoms per square micron up to hundreds of atomic layers, on a target ~1 mm away. Using a micron-scale silicon plate as a thermal evaporation source we demonstrate the deposition of indium, silver, gold, copper, iron, aluminum, lead and tin. Because of their small sizes and rapid thermal response times, pulse width modulation techniques are a powerful way to control the atomic flux. Pulsing the source with precise voltages and timing provides control in terms of when and how many atoms get deposited. By arranging many of these devices into an array, one has a multi-material, programmable solid state evaporation source. These micro atom sources are a complementary technology that can enhance the capability of a variety of nano-fabrication techniques.In this paper we discuss the development of a MEMS-based solid state atom source that can provide controllable atom deposition ranging over eight orders of magnitude, from ten atoms per square micron up to hundreds of atomic layers, on a target ~1 mm away. Using a micron-scale silicon plate as a thermal evaporation source we demonstrate the deposition of indium, silver, gold, copper, iron, aluminum, lead and tin. Because of their small sizes and rapid thermal response times, pulse width modulation techniques are a powerful way to control the atomic flux. Pulsing the source with precise voltages and timing provides control in terms of when and how many atoms get deposited. By arranging many of these devices into an array, one has a multi-material, programmable solid state evaporation source. These micro atom sources are a complementary technology that can enhance the capability of a variety of nano-fabrication techniques. Electronic supplementary information (ESI) available: A document containing further information about device characterization

  3. Low bone mass in microscopic colitis

    Directory of Open Access Journals (Sweden)

    Lakatos Péter

    2011-05-01

    Full Text Available Abstract Background Microscopic colitis presents with similar symptoms to classic inflammatory bowel diseases. Osteoporosis is a common complication of Crohn's disease but there are no data concerning bone metabolism in microscopic colitis. Aims The aim of the present study was to evaluate bone density and metabolism in patients with microscopic colitis. Methods Fourteen patients microscopic colitis were included in the study, and 28 healthy persons and 28 age and gender matched Crohn's disease patients were enrolled as controls. Bone mineral density was measured using dual x-ray absorptiometry at the lumbar spine, femoral neck and the radius. Serum bone formation and bone resorption markers (osteocalcin and beta-crosslaps, respectively were measured using immunoassays. Results Low bone mass was measured in 57.14% patients with microscopic colitis. Bone mineral density at the femoral neck in patients suffering from microscopic colitis and Crohn's disease was lower than in healthy controls (0.852 ± 0.165 and 0.807 ± 0.136 vs. 1.056 ± 0.126 g/cm2; p 2; p 2. Mean beta-crosslaps concentration was higher in microscopic colitis and Crohn's disease patients than controls (417.714 ± 250.37 and 466.071 ± 249.96 vs. 264.75 ± 138.65 pg/ml; p Conclusions Low bone mass is frequent in microscopic colitis, and alterations to bone metabolism are similar to those present in Crohn's disease. Therefore, microscopic colitis-associated osteopenia could be a significant problem in such patients.

  4. Directivity of Antenna Arrays

    Science.gov (United States)

    Bulgakova, A. A.; Gorobets, N. N.; Katrich, V. A.; Lyashchenko, V. A.

    2016-12-01

    Purpose: Theoretical investigation of directive gains of linear and planar antenna arrays depending on the distance between radiators and wavelength. Design/methodology/approach: Computing methods in applied mathematics in MathCad were used to calculate the twofold integrals of the radiation pattern over power throughout the whole space observed, defining the directivity in the most general terms. Patterns of radiators, i. e. elements of antenna arrays, are specified by mathematical models. The calculation accounts for the subintegral fast oscillating function. Findings: Calculations and analysis of a directive gain according to the number of radiators and distances between them in fractions of wavelength are made. It is shown that at the ratio of distance between radiators to wave-length being d/λ =0.5 the directivity of array of isotropic radiators is 1.5N², N - number of radiators. When increasing the d/λ to 0.65÷0.97 the directivity increases according to the law close to the linear one up to the maximum possible value for the specified number of radiators. With the increase of d/λ to the values greater than one, the directivity is significantly reduced (the “blinding” effect of non-phased antenna arrays) and its dependence with the growth of d/λ is decaying and oscillating in character. By that, the transfer function of antenna arrays has some vital difference from the transfer function of continuous antennas. Conclusions: Antenna arrays distort the waveform and spectrum of radiated and received signals as a result of irregular changes of their directivity depending on wavelength. The detected “blinding” effect of non-phased antenna arrays of large electrical dimensions must be taken into account in wideband and superwideband radio-electronics systems, especially in radio astronomy, telecommunications systems and superwideband radar.

  5. Auditing emergency management programmes: Measuring leading indicators of programme performance.

    Science.gov (United States)

    Tomsic, Heather

    Emergency Management Programmes benefit from review and measurement against established criteria. By measuring current vs required programme elements for their actual currency, completeness and effectiveness, the resulting timely reports of achievements and documentation of identified gaps can effectively be used to rationally support prioritised improvement. Audits, with their detailed, triangulated and objectively weighted processes, are the ultimate approach in terms of programme content measurement. Although Emergency Management is often presented as a wholly separate operational mechanism, distinct and functionally different from the organisation's usual management structure, this characterisation is only completely accurate while managing an emergency itself. Otherwise, an organisation's Emergency Management Programme is embedded within that organisation and dependent upon it. Therefore, the organisation's culture and structure of management, accountability and measurement must be engaged for the programme to exist, much less improve. A wise and successful Emergency Management Coordinator does not let the separate and distinct nature of managing an emergency obscure their realisation of the need for an organisation to understand and manage all of the other programme components as part of its regular business practices. This includes its measurement. Not all organisations are sufficiently large or capable of supporting the use of an audit. This paper proposes that alternate, less formal, yet effective mechanisms can be explored, as long as they reflect and support organisational management norms, including a process of relatively informal measurement focused on the organisation's own perception of key Emergency Management Programme performance indicators.

  6. The Mathematical Microscope - Making the inaccessible accessible

    DEFF Research Database (Denmark)

    Ottesen, Johnny T.

    2011-01-01

      In this chapter we introduce a new term, the "Mathematical Microscope", as a method of using mathematics in accessing information about reality when this information is otherwise inaccessible. Furthermore, we discuss how models and experiments are related: none of which are important without...... the other. In the sciences and medicine, a link that is often missing in the chain of a system can be made visible with the aid of the mathematical microscope. The mathematical microscope serves not only as a lens to clarify a blurred picture but more important as a tool to unveil profound truths...

  7. A video rate laser scanning confocal microscope

    Science.gov (United States)

    Ma, Hongzhou; Jiang, James; Ren, Hongwu; Cable, Alex E.

    2008-02-01

    A video-rate laser scanning microscope was developed as an imaging engine to integrate with other photonic building blocks to fulfill various microscopic imaging applications. The system is quipped with diode laser source, resonant scanner, galvo scanner, control electronic and computer loaded with data acquisition boards and imaging software. Based on an open frame design, the system can be combined with varies optics to perform the functions of fluorescence confocal microscopy, multi-photon microscopy and backscattering confocal microscopy. Mounted to the camera port, it allows a traditional microscope to obtain confocal images at video rate. In this paper, we will describe the design principle and demonstrate examples of applications.

  8. Summer Student Programme

    CERN Multimedia

    2006-01-01

    Date Time Title Speaker 05/07/2006 09:15 - 10:00 Presentation of the Summer Student Programme F. CERUTTI Information on Computing Rules D. HEAGERTY Workshops presentation O. ULLALAND 10:15 - 11:00 Introduction to CERN J. ENGELEN 11:15 Film on CERN 11:00 Introduction to Particle Physics F. CLOSE 11:15 - 12:00 Accelerators (1/5) S. GILARDONI / E. METRAL 12:00 Discussion Session 7/07/2006 09:15 - 11:00 Introduction to Particle Physics F. CLOSE 11:15 - 12:00 Accelerators (2/5) S. GILARDONI / E. METRAL 12:00 Discussion Session 09:15 - 10:00 Accelerators (3/5) S. GILARDONI / E. METRAL 10:15 - 12:00 Detectors (1-2/5) O. ULLALAND 12:00 Discussion Session 11/07/2006 09:15 - 10:00 Accelerators (4/5) S. GILARDONI / E. METRAL 10:15 - 11:00 Detectors (3/5) O. ULLALAND 11:15 - 12:00 Introduction to Nuclear Physics (1/4) P. CHOMAZ P. CHOMAZ 10:15 - 11:00 Accelerators (5/5) S. GILARDONI / E. METRAL 11:15 - 12:00 Detectors (4/5) O. ULLALAND 12:00 Discus...

  9. Management and Communication programme

    CERN Multimedia

    Nathalie Dumeaux

    2005-01-01

    We are pleased to announce the launch of three new courses in the Management and Communication programme: 1.     Managing Time (Open to all Staff Members) The objectives are: To enhance your personal effectiveness through better organisation skills To acquire ways of making the most of your time through improved work habits To reduce stress For the description of this course, please see:  http://humanresources.web.cern.ch/humanresources/external/training/MANCO/P9798/S8E_e.asp 2.     Service Orientation (Open to all Staff Members working in a service-related function) The objectives are: To understand the key elements in an effective client/service provider relationship To develop a client focused approach to providing services For the description of this course, please see:  http://humanresources.web.cern.ch/humanresources/external/training/MANCO/P9798/serv_e.asp 3.   Introduction to Leadership (Open to Staff in Career Paths E & above, including newly appointed supervisors and Sect...

  10. Management and Communication programme

    CERN Multimedia

    Nathalie Dumeaux

    2005-01-01

    We are pleased to announce the launch of three new courses in the Management and Communication programme: 1.     Managing Time (Open to all Staff Members) The objectives are: To enhance your personal effectiveness through better organisation skills To acquire ways of making the most of your time through improved work habits To reduce stress For the description of this course, please see:  http://humanresources.web.cern.ch/humanresources/external/training/MANCO/P9798/S8E_e.asp 2.     Service Orientation (Open to all Staff Members working in a service-related function) The objectives are: To understand the key elements in an effective client/service provider relationship To develop a client focused approach to providing services For the description of this course, please see:  http://humanresources.web.cern.ch/humanresources/external/training/MANCO/P9798/serv_e.asp 3.   Introduction to Leadership (Open to Staff in Career Paths E & above, including newly appointed supervisors and Secti...

  11. SUMMER STUDENT LECTURE PROGRAMME

    CERN Multimedia

    Françoise Benz

    2002-01-01

    SUMMER STUDENT LECTURE PROGRAMME Main Auditorium, bldg. 500   DATE TIME LECTURER TITLE Monday 29 July 09:15 - 10:00 R. RATTAZZI Beyond the Standard Model (3/3) 10:15 - 11:00 P. WELLS Experimental test of the SM - LEP (3/3) 11:15 - 12:00 P. WELLS Discussion Session 14:00 - 16:00 R. ASSMANN The CLIC Concept for a Future Particle Collider at the Energy Frontier Tuesday 30 July 09:15 - 10:00 F. ANTINORI Heavy Ions (1/2) 10:15 - 12:00 F. DYDAK Neutrino Physics (1&2/4) Wednesday 31 July  09:15 - 10:00 F. ANTINORI Heavy Ions (2/2) 10:15 - 11:00 F. DYDAK Neutrino Physics (3/4) 11:15 - 12:00 F. DYDAK / F. ANTINORI Discussion Session Thursday 1 August 09:15 - 10:00 T. NAKADA CP Violation (1/4) 10:15 - 11:00 F. DYDAK Neutrino Physics (4/4) 11:15 - 12:00 F. BEDESCHI Experimental test of the SM Tevatron (1/2) Friday 2 August 09:15 - 10:00 T. NAKADA CP Violation (2/4) 10:15 ? 11:00 F. BEDESCHI Experimental test of the SM Tevatron (2/2) 11:15 ? 12:00 F. BEDESCHI / T. NAKADA Di...

  12. Photovoltaic programme, edition 2004

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2004-07-01

    This comprehensive publication issued by the Swiss Federal Office of Energy's Photovoltaics (PV) Programme presents an overview (in English) of activities and projects in the photovoltaics research and pilot and demonstration areas in Switzerland for the year 2003. Progress in future solar cell technologies as well as in the area of modules, building integration and system technologies is summarised. Also, national and international co-operation and multi-national pilot and demonstration projects are commented on. Associated projects such as eco-balances for PV systems, forecasting and modelling tools as well as system monitoring tools are discussed. In the area of pilot and demonstration projects, component development, PV integration in sloping roofs, on flat roofs and on facades as well as further PV plant are looked at. Also, measurement campaigns, studies, statistics and other PV-related topics are summarised. This volume presents a list of 92 projects in the PV area including the appropriate Internet links and is completed with a collection of project abstracts.

  13. Summer Student Lecture Programme

    CERN Multimedia

    2004-01-01

    Main Auditorium, bldg. 500 More Information DATE TIME LECTURER TITLE Wednesday 7 July 09:15 - 10:00 L. Fayard, O. Ullaland, D. Heagerty (CERN) Programme Presentation Workshops presentation Information on Computing Rules 10:15 - 11:00 R. Aymar (CERN) Introduction to CERN (1/2) 11:15 - 12:00 J. Engelen (CERN) Introduction to CERN (2/2) 15:00 - 16:30 H. Menzel (CERN) An Introduction to Radiation Protection DATE TIME LECTURER TITLE Thursday 8 july 09:15 - 10:00 L. Di Lella (CERN) Introduction to Particle Physics (1/4) 10:15 - 11:00 L. Di Lella (CERN) Introduction to Particle Physics (2/4) 11:15 - 12:00 P. Chomaz (GANIL / CERN) Fundamental questions in modern nuclear physics: The challenge of exotic nuclei (1/2) DATE TIME LECTURER TITLE Friday 9 July 09:15 - 10:00 L. Di Lella (CERN) Introduction to Particle Physics (3/4) 10:15 - 11:00 P. Chomaz (GANIL / CERN) Fundamental questions in modern nuclear physics: The challenge of exotic nuclei (2/2) 11:15 - 12:00 P....

  14. Efficient Array Design for Sonotherapy

    OpenAIRE

    Stephens, Douglas N.; Kruse, Dustin E.; Ergun, Arif S.; Barnes, Stephen; Ming Lu, X.; Ferrara, Katherine

    2008-01-01

    New linear multi-row, multi-frequency arrays have been designed, constructed and tested as fully operational ultrasound probes to produce confocal imaging and therapeutic acoustic intensities with a standard commercial ultrasound imaging system. The triple-array probes and imaging system produce high quality B-mode images with a center row imaging array at 5.3 MHz, and sufficient acoustic power with dual therapeutic arrays to produce mild hyperthermia at 1.54 MHz. The therapeutic array pair i...

  15. South African southern ocean research programme

    CSIR Research Space (South Africa)

    SASCAR

    1987-01-01

    Full Text Available This document describes the South African National Antarctic Research Programme's (SANARP) physical, chemical and biological Southern Ocean research programme. The programme has three main components: ecological studies of the Prince Edward Islands...

  16. 3D printing of microscopic bacterial communities

    National Research Council Canada - National Science Library

    Jodi L. Connell; Eric T. Ritschdorff; Marvin Whiteley; Jason B. Shear

    2013-01-01

    .... Here, we describe a microscopic threedimensional (3D) printing strategy that enables multiple populations of bacteria to be organized within essentially any 3D geometry, including adjacent, nested, and free-floating...

  17. Special Microscopy Using a Standard Student Microscope.

    Science.gov (United States)

    Sundberg, Marshall D.

    1984-01-01

    Explains the procedures used in a general botany course to obtain polarization, fluorescence, and dark field images using a standard student microscope. Provides sources for materials and references. (JM)

  18. A pragmatic guide to multiphoton microscope design

    Science.gov (United States)

    Young, Michael D.; Field, Jeffrey J.; Sheetz, Kraig E.; Bartels, Randy A.; Squier, Jeff

    2016-01-01

    Multiphoton microscopy has emerged as a ubiquitous tool for studying microscopic structure and function across a broad range of disciplines. As such, the intent of this paper is to present a comprehensive resource for the construction and performance evaluation of a multiphoton microscope that will be understandable to the broad range of scientific fields that presently exploit, or wish to begin exploiting, this powerful technology. With this in mind, we have developed a guide to aid in the design of a multiphoton microscope. We discuss source selection, optical management of dispersion, image-relay systems with scan optics, objective-lens selection, single-element light-collection theory, photon-counting detection, image rendering, and finally, an illustrated guide for building an example microscope. PMID:27182429

  19. Understanding and caring for an operating microscope

    Directory of Open Access Journals (Sweden)

    Ismael Cordero

    2014-04-01

    Full Text Available An operating or surgical microscope is an optical instrument that provides the surgeon with a stereoscopic, high quality magnified and illuminated image of the small structures in the surgical area.

  20. Adapting Nepal's polio eradication programme.

    Science.gov (United States)

    Paudel, Krishna P; Hampton, Lee M; Gurung, Santosh; Bohara, Rajendra; Rai, Indra K; Anaokar, Sameer; Swift, Rachel D; Cochi, Stephen

    2017-03-01

    Many countries have weak disease surveillance and immunization systems. The elimination of polio creates an opportunity to use staff and assets from the polio eradication programme to control other vaccine-preventable diseases and improve disease surveillance and immunization systems. In 2003, the active surveillance system of Nepal's polio eradication programme began to report on measles and neonatal tetanus cases. Japanese encephalitis and rubella cases were added to the surveillance system in 2004. Staff from the programme aided the development and implementation of government immunization policies, helped launch vaccination campaigns, and trained government staff in reporting practices and vaccine management. Nepal eliminated indigenous polio in 2000, and controlled outbreaks caused by polio importations between 2005 and 2010. In 2014, the surveillance activities had expanded to 299 sites, with active surveillance for measles, rubella and neonatal tetanus, including weekly visits from 15 surveillance medical officers. Sentinel surveillance for Japanese encephalitis consisted of 132 sites. Since 2002, staff from the eradication programme have helped to introduce six new vaccines and helped to secure funding from Gavi, the Vaccine Alliance. Staff have also assisted in responding to other health events in the country. By expanding the activities of its polio eradication programme, Nepal has improved its surveillance and immunization systems and increased vaccination coverage of other vaccine-preventable diseases. Continued donor support, a close collaboration with the Expanded Programme on Immunization, and the retention of the polio eradication programme's skilled workforce were important for this expansion.

  1. Phased array imaging

    Science.gov (United States)

    1990-09-01

    The problem of recoverable image resolution is investigated for the case where an imaging array is used which array has an optical transfer function that may be described as consisting of islands of nonzero value in a sea of zero values. Can the missing spatial frequency information can be provided--can, in effect, a form of (interpolative) super resolution. The CLEAN algorithm used by radio astronomers suggests that this should be possible. The results developed here indicate that this can be done, with no significant price in terms of signal-to-noise ratio to be paid, and further show that a nonlinear algorithm, like CLEAN, is not required. The results show that the feasibility of doing this depends on the angular size of the object being imaged. We find that its size must be less than the inverse of the largest gap between islands in the array's optical transfer function.

  2. Surface Plasmon Polariton microscope with Parabolic Reflectors

    OpenAIRE

    Drezet, Aurelien; Koller, Daniel; Hohenau, Andreas; Leitner, Alfred; Aussenegg, Franz R.; Krenn, Joachim R.

    2010-01-01

    We report the realization of a two--dimensional optical microscope for surface plasmons polaritons (SPPs) based on parabolic Bragg mirrors. These mirrors are built from lithographically fabricated gold nanostructures on gold thin films. We show by direct imaging by leakage radiation microscopy that the magnification power of the SPP microscope follows basic predictions of geometrical optics. Spatial resolution down to the value set by the diffraction limit is demonstrated.

  3. [Color television microscope with an automatic stage].

    Science.gov (United States)

    Miao, Z; Liu, S; Xuan, Z; Zhao, Q; Liu, R

    1997-09-01

    To mount a group of stepper motors on a television microscope automates the instrument in coarse focussing and equi-spaced moving a specimen. A microprocessor 8031 application system is used to control the stepper motors. For enhancing the properties and reliability of the system, we select RIF 530, a field effect transistor for the power amplifier of the motor. Combination PC with the instrument becomes basic hardware of a universal microscopic image processing system.

  4. Microscopic polyangiitis: An unusual neurologic complication

    Directory of Open Access Journals (Sweden)

    Hayet Kaaroud

    2011-01-01

    Full Text Available Microscopic polyangiitis is a systemic necrotizing vasculitis of the small vessels. Its typical clinical manifestations are rapidly progressive glomerulonephritis and alveolar hemorrhage. We describe a 30-year-old woman with rapidly progressive glomerulonephritis. Seven years later, she presented with partial loss of motor and sensory function in both lower limbs with sphincter dysfunction. This is the first reported case of epidural inflammation ascribed to microscopic poly-angiitis. Possible mechanisms include auto-immune disease.

  5. X-ray laser microscope apparatus

    Science.gov (United States)

    Suckewer, Szymon; DiCicco, Darrell S.; Hirschberg, Joseph G.; Meixler, Lewis D.; Sathre, Robert; Skinner, Charles H.

    1990-01-01

    A microscope consisting of an x-ray contact microscope and an optical microscope. The optical, phase contrast, microscope is used to align a target with respect to a source of soft x-rays. The source of soft x-rays preferably comprises an x-ray laser but could comprise a synchrotron or other pulse source of x-rays. Transparent resist material is used to support the target. The optical microscope is located on the opposite side of the transparent resist material from the target and is employed to align the target with respect to the anticipated soft x-ray laser beam. After alignment with the use of the optical microscope, the target is exposed to the soft x-ray laser beam. The x-ray sensitive transparent resist material whose chemical bonds are altered by the x-ray beam passing through the target mater GOVERNMENT LICENSE RIGHTS This invention was made with government support under Contract No. De-FG02-86ER13609 awarded by the Department of Energy. The Government has certain rights in this invention.

  6. IMIS: An intelligence microscope imaging system

    Science.gov (United States)

    Caputo, Michael; Hunter, Norwood; Taylor, Gerald

    1994-01-01

    Until recently microscope users in space relied on traditional microscopy techniques that required manual operation of the microscope and recording of observations in the form of written notes, drawings, or photographs. This method was time consuming and required the return of film and drawings from space for analysis. No real-time data analysis was possible. Advances in digital and video technologies along with recent developments in article intelligence will allow future space microscopists to have a choice of three additional modes of microscopy: remote coaching, remote control, and automation. Remote coaching requires manual operations of the microscope with instructions given by two-way audio/video transmission during critical phases of the experiment. When using the remote mode of microscopy, the Principal Investigator controls the microscope from the ground. The automated mode employs artificial intelligence to control microscope functions and is the only mode that can be operated in the other three modes as well. The purpose of this presentation is to discuss the advantages and disadvantages of the four modes of of microscopy and how the IMIS, a proposed intelligent microscope imaging system, can be used as a model for developing and testing concepts, operating procedures, and equipment design of specifications required to provide a comprehensive microscopy/imaging capability onboard Space Station Freedom.

  7. Photovoltaic array performance model.

    Energy Technology Data Exchange (ETDEWEB)

    Kratochvil, Jay A.; Boyson, William Earl; King, David L.

    2004-08-01

    This document summarizes the equations and applications associated with the photovoltaic array performance model developed at Sandia National Laboratories over the last twelve years. Electrical, thermal, and optical characteristics for photovoltaic modules are included in the model, and the model is designed to use hourly solar resource and meteorological data. The versatility and accuracy of the model has been validated for flat-plate modules (all technologies) and for concentrator modules, as well as for large arrays of modules. Applications include system design and sizing, 'translation' of field performance measurements to standard reporting conditions, system performance optimization, and real-time comparison of measured versus expected system performance.

  8. Solar array welding developement

    Science.gov (United States)

    Elms, R. V., Jr.

    1974-01-01

    The present work describes parallel gap welding as used for joining solar cells to the cell interconnect system. Sample preparation, weldable cell parameter evaluation, bond scheduling, bond strength evaluation, and bonding and thermal shock tests are described. A range of weld schedule parameters - voltage, time, and force - can be identified for various cell/interconnect designs that will provide adequate bond strengths and acceptably small electrical degradation. Automation of solar array welding operations to a significant degree has been achieved in Europe and will be receiving increased attention in the U.S. to reduce solar array fabrication costs.

  9. Implementing universal vaccination programmes: Spain.

    Science.gov (United States)

    de la Torre, J; Esteban, R

    1995-01-01

    Until 1990, the immunization policy against hepatitis B in Spain was selective high-risk vaccination. That policy failed to reduce the incidence of hepatitis B and the prevalence rates of chronic carriers. In 1991, Catalonia began a universal immunization programme targeted at 12-year-olds. Six other regions (Castilla-León, Valencia, Extramadura, Navarra, the Balearic Islands and Rioja) introduced vaccination programmes in 1992. In 1993, three more regions (Galicia, Castilla-La-Mancha and Pais Vasco) began immunizing young adolescents. This means that 12-year-olds in Spain are now included in vaccination programmes against hepatitis B.

  10. A Statistical Programme Assignment Model

    DEFF Research Database (Denmark)

    Rosholm, Michael; Staghøj, Jonas; Svarer, Michael

    When treatment effects of active labour market programmes are heterogeneous in an observable way  across the population, the allocation of the unemployed into different programmes becomes a particularly  important issue. In this paper, we present a statistical model designed to improve the present...... duration of unemployment spells may result if a statistical programme assignment model is introduced. We discuss several issues regarding the  plementation of such a system, especially the interplay between the statistical model and  case workers....

  11. Automatic TLI recognition system, programmer`s guide

    Energy Technology Data Exchange (ETDEWEB)

    Lassahn, G.D.

    1997-02-01

    This report describes the software of an automatic target recognition system (version 14), from a programmer`s point of view. The intent is to provide information that will help people who wish to modify the software. In separate volumes are a general description of the ATR system, Automatic TLI Recognition System, General Description, and a user`s manual, Automatic TLI Recognition System, User`s Guide. 2 refs.

  12. High resolution, high speed, long working distance, large field of view confocal fluorescence microscope.

    Science.gov (United States)

    Pacheco, Shaun; Wang, Chengliang; Chawla, Monica K; Nguyen, Minhkhoi; Baggett, Brend K; Utzinger, Urs; Barnes, Carol A; Liang, Rongguang

    2017-10-17

    Confocal fluorescence microscopy is often used in brain imaging experiments, however conventional confocal microscopes are limited in their field of view, working distance, and speed for high resolution imaging. We report here the development of a novel high resolution, high speed, long working distance, and large field of view confocal fluorescence microscope (H2L2-CFM) with the capability of multi-region and multifocal imaging. To demonstrate the concept, a 0.5 numerical aperture (NA) confocal fluorescence microscope is prototyped with a 3 mm × 3 mm field of view and 12 mm working distance, an array of 9 beams is scanned over the field of view in 9 different regions to speed up the acquisition time by a factor of 9. We test this custom designed confocal fluorescence microscope for future use with brain clarification methods to image large volumes of the brain at subcellular resolution. This multi-region and multi-spot imaging method can be used in other imaging modalities, such as multiphoton microscopes, and the field of view can be extended well beyond 12 mm × 12 mm.

  13. The Digital Microscope and Its Image Processing Utility

    OpenAIRE

    Tri Wahyu Supardi; Agus Harjoko; Sri Hartati

    2011-01-01

    Many institutions, including high schools, own a large number of analog or ordinary microscopes. These microscopes are used to observe small objects. Unfortunately, object observations on the ordinary microscope require precision and visual acuity of the user. This paper discusses the development of a high-resolution digital microscope from an analog microscope, including the image processing utility, which allows the digital microscope users to capture, store and process the digital images o...

  14. Virtual reality microscope versus conventional microscope regarding time to diagnosis: an experimental study.

    OpenAIRE

    Randell, R; Ruddle, RA; Mello-Thoms, C; Thomas, RG; Quirke, P; Treanor, D

    2013-01-01

    Aims:  To create and evaluate a virtual reality (VR) microscope that is as efficient as the conventional microscope, seeking to support the introduction of digital slides into routine practice. Methods and results:  A VR microscope was designed and implemented by combining ultra-high-resolution displays with VR technology, techniques for fast interaction, and high usability. It was evaluated using a mixed factorial experimental design with technology and task as within-participant variables a...

  15. Summer Research Fellowship Programme 2018

    Indian Academy of Sciences (India)

    Date of birth: 2 September 1957. Specialization: Cosmic Magnetic Fields, Structure Formation, Cosmology Address: Distinguished Professor & Dean, Visitor Academic Programmes, Inter-University Centre for Astronomy & Astrophysics, Post Bag 4, Ganeshkhind, Pune 411 007, Maharashtra Contact: Office: (020) 2560 4101

  16. Climate Ambassador Programmes in Municipalities

    DEFF Research Database (Denmark)

    Jørgensen, Michael Søgaard; Pedersen, Stine Rahbek

    2016-01-01

    in the municipalities of Furesø, Lyngby-Taarbæk, Frederiksberg and Hvidovre. Two of the ambassador programmes presented here focus primarily on climate change mitigation initiatives, and two have a broader focus on sustainable development. Important elements for the impact of these programmes are the networking among......Some Danish municipalities have developed ambassador programmes which generate environmental and climate change mitigation efforts in local public administrations and institutions. This chapter analyses the characteristics and experiences of four ambassador programmes now operating...... the local ambassadors, the central coordinator’s ability to support the local ambassador with knowledge about mapping, reduction of environmental impacts and facilitation of development of initiatives, and mechanisms for the allocation of cost savings from local resource savings....

  17. CERN openlab Summer Student Programme

    CERN Multimedia

    2012-01-01

    CERN openlab is currently taking applications for its summer student programme. The closing date for applications is 30 March 2012.   The openlab Summer Student Programme is open for applications from bachelor, master and PhD students in computer science and physics. Successful applicants will spend 8 weeks at CERN, during the period June to September 2012, to work with some of the latest hardware and software technologies. The programme is more than just a summer at CERN: it can lead to follow-on projects at the home institute and may even inspire the students to become entrepreneurs in cutting-edge computing technologies. A series of lectures will be given by experts in various domains of CERN related high-throughput computing. Study tours to external companies and universities as well as to CERN facilities are also part of the programme. Please visit www.cern.ch/openlab-students for more information.

  18. CERN openlab summer student programme

    CERN Multimedia

    2013-01-01

    CERN openlab is currently taking applications for its summer student programme. The closing date for applications is 31 March 2013.   The openlab summer student programme is open for applications from bachelor, master and PhD students in computer science and physics. Successful applicants will spend 9 weeks at CERN, during the period from June to September 2013, working with some of the latest hardware and software technologies. The programme is more than just a summer at CERN: it can lead to follow-on projects at the home institute and may even inspire students to become entrepreneurs in cutting-edge computing technologies. A series of lectures will be given by experts in various domains of CERN-related high-throughput computing. Study tours of external companies and universities as well as of CERN facilities are also part of the programme. Please visit the CERN openlab website for more information.

  19. Digitally Controlled Slot Coupled Patch Array

    Science.gov (United States)

    D'Arista, Thomas; Pauly, Jerry

    2010-01-01

    A four-element array conformed to a singly curved conducting surface has been demonstrated to provide 2 dB axial ratio of 14 percent, while maintaining VSWR (voltage standing wave ratio) of 2:1 and gain of 13 dBiC. The array is digitally controlled and can be scanned with the LMS Adaptive Algorithm using the power spectrum as the objective, as well as the Direction of Arrival (DoA) of the beam to set the amplitude of the power spectrum. The total height of the array above the conducting surface is 1.5 inches (3.8 cm). A uniquely configured microstrip-coupled aperture over a conducting surface produced supergain characteristics, achieving 12.5 dBiC across the 2-to-2.13- GHz and 2.2-to-2.3-GHz frequency bands. This design is optimized to retain VSWR and axial ratio across the band as well. The four elements are uniquely configured with respect to one another for performance enhancement, and the appropriate phase excitation to each element for scan can be found either by analytical beam synthesis using the genetic algorithm with the measured or simulated far field radiation pattern, or an adaptive algorithm implemented with the digitized signal. The commercially available tuners and field-programmable gate array (FPGA) boards utilized required precise phase coherent configuration control, and with custom code developed by Nokomis, Inc., were shown to be fully functional in a two-channel configuration controlled by FPGA boards. A four-channel tuner configuration and oscilloscope configuration were also demonstrated although algorithm post-processing was required.

  20. Array Theory and Nial

    DEFF Research Database (Denmark)

    Falster, Peter; Jenkins, Michael

    1999-01-01

    This report is the result of collaboration between the authors during the first 8 months of 1999 when M. Jenkins was visiting professor at DTU. The report documents the development of a tool for the investigation of array theory concepts and in particular presents various approaches to choose...

  1. TANGO Array. 2. Simulations

    Energy Technology Data Exchange (ETDEWEB)

    Bauleo, P. E-mail: pablo.bauleo@colostate.edu; Bonifazi, C.; Filevich, A

    2004-01-11

    The angular and energy resolutions of the TANGO Array were obtained using extensive Monte Carlo simulations performed with a double purpose: (1) to determine the appropriate parameters for the array fitting to the desired range of sensitivity (the knee energy region), and (2) to construct a reliable shower database required for reference in the analysis of experimental data. The AIRES code, with the SIBYLL hadronic collision package, was used to simulate Extended Air Showers produced by primary cosmic rays (assuming protons and iron nuclei), with energies ranging from 10{sup 14} to 10{sup 18} eV. These data were fed into a realistic code which simulates the response of the detectors (water Cherenkov detectors), including the electronics, pickup noise, and the signal attenuation in the connecting cables. The trigger stage was considered in the simulations in order to estimate the trigger efficiency of the array and to verify the accuracy of the reconstruction codes. This paper delineates the simulations performed to obtain the expected behavior of the array, and describes the simulated data. The results of these simulations suggest that we can expect an error in the energy of the primary cosmic-ray of {approx}60% of the estimated value and that the error in the measurement of the direction of arrival can be estimated as {approx}4 deg. . The present simulations also indicate that unambiguous assignments of the primary energy cannot be obtained because of the uncertainty in the nature of the primary cosmic ray.

  2. TANGO Array.. 2. Simulations

    Science.gov (United States)

    Bauleo, P.; Bonifazi, C.; Filevich, A.

    2004-01-01

    The angular and energy resolutions of the TANGO Array were obtained using extensive Monte Carlo simulations performed with a double purpose: (1) to determine the appropriate parameters for the array fitting to the desired range of sensitivity (the knee energy region), and (2) to construct a reliable shower database required for reference in the analysis of experimental data. The AIRES code, with the SIBYLL hadronic collision package, was used to simulate Extended Air Showers produced by primary cosmic rays (assuming protons and iron nuclei), with energies ranging from 10 14 to 10 18 eV. These data were fed into a realistic code which simulates the response of the detectors (water Cherenkov detectors), including the electronics, pickup noise, and the signal attenuation in the connecting cables. The trigger stage was considered in the simulations in order to estimate the trigger efficiency of the array and to verify the accuracy of the reconstruction codes. This paper delineates the simulations performed to obtain the expected behavior of the array, and describes the simulated data. The results of these simulations suggest that we can expect an error in the energy of the primary cosmic-ray of ˜60% of the estimated value and that the error in the measurement of the direction of arrival can be estimated as ˜4°. The present simulations also indicate that unambiguous assignments of the primary energy cannot be obtained because of the uncertainty in the nature of the primary cosmic ray.

  3. Array processors in chemistry

    Energy Technology Data Exchange (ETDEWEB)

    Ostlund, N.S.

    1980-01-01

    The field of attached scientific processors (''array processors'') is surveyed, and an attempt is made to indicate their present and possible future use in computational chemistry. The current commercial products from Floating Point Systems, Inc., Datawest Corporation, and CSP, Inc. are discussed.

  4. Field Evaluation of Programmable Thermostats

    Energy Technology Data Exchange (ETDEWEB)

    Sachs, O. [Fraunhofer Center for Sustainable Energy Systems (CSE), Cambridge, MA (United States); Tiefenbeck, V. [Fraunhofer Center for Sustainable Energy Systems (CSE), Cambridge, MA (United States); Duvier, C. [Fraunhofer Center for Sustainable Energy Systems (CSE), Cambridge, MA (United States); Qin, A. [Fraunhofer Center for Sustainable Energy Systems (CSE), Cambridge, MA (United States); Cheney, K. [Fraunhofer Center for Sustainable Energy Systems (CSE), Cambridge, MA (United States); Akers, C. [Fraunhofer Center for Sustainable Energy Systems (CSE), Cambridge, MA (United States); Roth, K. [Fraunhofer Center for Sustainable Energy Systems (CSE), Cambridge, MA (United States)

    2012-12-01

    Prior research suggests that poor programmable thermostats usability may prevent their effective use to save energy. The Fraunhofer team hypothesized that home occupants with high-usability thermostats would be more likely to use them to save energy than people with a basic thermostats. In this report, the team discusses results of a project in which the team monitored and compared programmable thermostats with basic thermostats in an affordable housing apartment complex.

  5. Scarabee programme and associated trials

    Energy Technology Data Exchange (ETDEWEB)

    Meyer-Heine, A.; Schmitt, A.P.; Aujollet, J.M.; Fortunato, M.; Chaudat, J.P. (Departement de Surete Nucleaire, CEA Fontenay-aux-Roses, 92 (France)); Penet, F. (CEA Cadarache, 13 - Saint-Paul-les-Durance (France)); Costa, J. (CEA Saclay, 91 - Gif-sur-Yvette (France)); Simeon, C. (SEPTEN-EDF, 92 - Clamart)

    This article describes the Scarabee set-up and the programme conducted in this experimental reactor, designed for the study of assembly accidents in the fast neutron field. Out-pile experiments carried out in support of the Scarabee programme are then presented. Two lines of research are distinguished: thermohydraulic (local obstructions, sodium boiling, melting of cladding) and fuel baths. Some studies more specific to molten fuels are also mentioned.

  6. Silicon Micromachined Microlens Array for THz Antennas

    Science.gov (United States)

    Lee, Choonsup; Chattopadhyay, Goutam; Mehdi, IImran; Gill, John J.; Jung-Kubiak, Cecile D.; Llombart, Nuria

    2013-01-01

    5 5 silicon microlens array was developed using a silicon micromachining technique for a silicon-based THz antenna array. The feature of the silicon micromachining technique enables one to microfabricate an unlimited number of microlens arrays at one time with good uniformity on a silicon wafer. This technique will resolve one of the key issues in building a THz camera, which is to integrate antennas in a detector array. The conventional approach of building single-pixel receivers and stacking them to form a multi-pixel receiver is not suited at THz because a single-pixel receiver already has difficulty fitting into mass, volume, and power budgets, especially in space applications. In this proposed technique, one has controllability on both diameter and curvature of a silicon microlens. First of all, the diameter of microlens depends on how thick photoresist one could coat and pattern. So far, the diameter of a 6- mm photoresist microlens with 400 m in height has been successfully microfabricated. Based on current researchers experiences, a diameter larger than 1-cm photoresist microlens array would be feasible. In order to control the curvature of the microlens, the following process variables could be used: 1. Amount of photoresist: It determines the curvature of the photoresist microlens. Since the photoresist lens is transferred onto the silicon substrate, it will directly control the curvature of the silicon microlens. 2. Etching selectivity between photoresist and silicon: The photoresist microlens is formed by thermal reflow. In order to transfer the exact photoresist curvature onto silicon, there needs to be etching selectivity of 1:1 between silicon and photoresist. However, by varying the etching selectivity, one could control the curvature of the silicon microlens. The figure shows the microfabricated silicon microlens 5 x5 array. The diameter of the microlens located in the center is about 2.5 mm. The measured 3-D profile of the microlens surface has a

  7. Designs for a quantum electron microscope.

    Science.gov (United States)

    Kruit, P; Hobbs, R G; Kim, C-S; Yang, Y; Manfrinato, V R; Hammer, J; Thomas, S; Weber, P; Klopfer, B; Kohstall, C; Juffmann, T; Kasevich, M A; Hommelhoff, P; Berggren, K K

    2016-05-01

    One of the astounding consequences of quantum mechanics is that it allows the detection of a target using an incident probe, with only a low probability of interaction of the probe and the target. This 'quantum weirdness' could be applied in the field of electron microscopy to generate images of beam-sensitive specimens with substantially reduced damage to the specimen. A reduction of beam-induced damage to specimens is especially of great importance if it can enable imaging of biological specimens with atomic resolution. Following a recent suggestion that interaction-free measurements are possible with electrons, we now analyze the difficulties of actually building an atomic resolution interaction-free electron microscope, or "quantum electron microscope". A quantum electron microscope would require a number of unique components not found in conventional transmission electron microscopes. These components include a coherent electron beam-splitter or two-state-coupler, and a resonator structure to allow each electron to interrogate the specimen multiple times, thus supporting high success probabilities for interaction-free detection of the specimen. Different system designs are presented here, which are based on four different choices of two-state-couplers: a thin crystal, a grating mirror, a standing light wave and an electro-dynamical pseudopotential. Challenges for the detailed electron optical design are identified as future directions for development. While it is concluded that it should be possible to build an atomic resolution quantum electron microscope, we have also identified a number of hurdles to the development of such a microscope and further theoretical investigations that will be required to enable a complete interpretation of the images produced by such a microscope. Copyright © 2016 The Authors. Published by Elsevier B.V. All rights reserved.

  8. Digitally Programmable High-Q Voltage Mode Universal Filter

    Directory of Open Access Journals (Sweden)

    D. Singh

    2013-12-01

    Full Text Available A new low-voltage low-power CMOS current feedback amplifier (CFA is presented in this paper. This is used to realize a novel digitally programmable CFA (DPCFA using transistor arrays and MOS switches. The proposed realizations nearly allow rail-to-rail swing capability at all the ports. Class-AB output stage ensures low power dissipation and high current drive capability. The proposed CFA/ DPCFA operates at supply voltage of ±0.75 V and exhibits bandwidth better than 95 MHz. An application of the DPCFA to realize a novel voltage mode high-Q digitally programmable universal filter (UF is given. Performances of all the proposed circuits are verified by PSPICE simulation using TSMC 0.25μm technology parameters.

  9. Norwegian mastitis control programme

    Directory of Open Access Journals (Sweden)

    Østerås O

    2009-04-01

    changes in attitude and breeding, eradicating bovine virus diarrhoea virus (BVDV and a better implementation of mastitis prevention programmes.

  10. Norwegian mastitis control programme

    Science.gov (United States)

    2009-01-01

    breeding, eradicating bovine virus diarrhoea virus (BVDV) and a better implementation of mastitis prevention programmes. PMID:22081877

  11. [Programmes against depression].

    Science.gov (United States)

    Taleb, M; Rouillon, F; Hegerl, U; Hamdani, N; Gorwood, Ph

    2006-01-01

    frequently criticized, as this may reduce efficacy. A multilevel approach is crucial for the success of action programmes against depression, because synergistic effects can be expected. In Germany, the "Nürnberger Bündnis gegen Depression" project was based on four levels, and effectively reduced the suicide rate. These levels of action included "cooperation with GPs", such as training sessions based on video, and presence of a phone hotline, "public relations activities", "training sessions for multipliers", such as priests, social workers and media, and "special offers for high risk groups and self-help activities". In France, such a program is clearly required.

  12. The optics of microscope image formation.

    Science.gov (United States)

    Wolf, David E

    2013-01-01

    Although geometric optics gives a good understanding of how the microscope works, it fails in one critical area, which is explaining the origin of microscope resolution. To accomplish this, one must consider the microscope from the viewpoint of physical optics. This chapter describes the theory of the microscope-relating resolution to the highest spatial frequency that a microscope can collect. The chapter illustrates how Huygens' principle or construction can be used to explain the propagation of a plane wave. It is shown that this limit increases with increasing numerical aperture (NA). As a corollary to this, resolution increases with decreasing wavelength because of how NA depends on wavelength. The resolution is higher for blue light than red light. Resolution is dependent on contrast, and the higher the contrast, the higher the resolution. This last point relates to issues of signal-to-noise and dynamic range. The use of video and new digital cameras has necessitated redefining classical limits such as those of Rayleigh's criterion. Copyright © 2007 Elsevier Inc. All rights reserved.

  13. Microscopic fungi as significant sesquiterpene emission sources

    Science.gov (United States)

    HorváTh, Eszter; Hoffer, AndráS.; SebőK, Flóra; Dobolyi, Csaba; Szoboszlay, SáNdor; Kriszt, BaláZs; GelencséR, AndráS.

    2011-08-01

    Among the volatile organic compounds emitted by vegetation, isoprene, monoterpenes, sesquiterpenes, and their derivatives are thought to contribute to secondary organic aerosol formation. Although it is well known that microscopic fungi globally turn over vast amount of carbon by decomposing the organic matter in the soil, vegetation is considered as the exclusive source of biogenic secondary organic aerosol precursors in various atmospheric models. Secondary fungal metabolites including sesquiterpenes have been recognized as characteristic volatile organic compounds emitted by fungi. In the present study, we investigated the rates of sesquiterpene emission of microscopic fungi to establish their potential significance compared to those from vegetation. To sample the headspace of the pure culture of some common fungi, we used an aseptic flow-through apparatus designed for solid phase microextraction in our laboratory. The identified sesquiterpenes in the headspace extracts were quantified for eight strains of microscopic fungi belonging to four different genera. Our results showed that microscopic fungi emit a considerable amount of sesquiterpenes. Based on our first estimations microscopic fungi may be considered as potentially significant sesquiterpene emission sources whose contribution to secondary organic aerosol formation may be comparable to that of vegetation.

  14. Microscopic colitis: clinical and pathologic perspectives.

    Science.gov (United States)

    Münch, Andreas; Langner, Cord

    2015-02-01

    Microscopic colitis is a chronic inflammatory bowel disease characterized by chronic nonbloody diarrhea and specific histopathology features. Active disease, defined as 3 or more stools or 1 or more watery stools per day, significantly reduces quality of life. Epidemiologic studies have found the incidence and prevalence of microscopic colitis to be comparable with those of Crohn's disease and ulcerative colitis. Nevertheless, microscopic colitis is still under-recognized in clinical practice-most health care workers know little about its etiology and pathophysiology. Furthermore, there are many challenges to the diagnosis and treatment of patients. We review the epidemiologic and clinical features of this disorder and discuss its pathogenesis. We also outline the criteria for histopathologic evaluation of microscopic colitis, recently published by the European Consensus on Inflammatory Bowel Disease, and discuss a treatment algorithm created by the European Microscopic Colitis Group. Treatment options for patients with budesonide-refractory disease are discussed. Copyright © 2015 AGA Institute. Published by Elsevier Inc. All rights reserved.

  15. Array microscopy technology and its application to digital detection of Mycobacterium tuberculosis

    Science.gov (United States)

    McCall, Brian P.

    Tuberculosis causes more deaths worldwide than any other curable infectious disease. This is the case despite tuberculosis appearing to be on the verge of eradication midway through the last century. Efforts at reversing the spread of tuberculosis have intensified since the early 1990s. Since then, microscopy has been the primary frontline diagnostic. In this dissertation, advances in clinical microscopy towards array microscopy for digital detection of Mycobacterium tuberculosis are presented. Digital array microscopy separates the tasks of microscope operation and pathogen detection and will reduce the specialization needed in order to operate the microscope. Distributing the work and reducing specialization will allow this technology to be deployed at the point of care, taking the front-line diagnostic for tuberculosis from the microscopy center to the community health center. By improving access to microscopy centers, hundreds of thousands of lives can be saved. For this dissertation, a lens was designed that can be manufactured as 4x6 array of microscopes. This lens design is diffraction limited, having less than 0.071 waves of aberration (root mean square) over the entire field of view. A total area imaged onto a full-frame digital image sensor is expected to be 3.94 mm2, which according to tuberculosis microscopy guidelines is more than sufficient for a sensitive diagnosis. The design is tolerant to single point diamond turning manufacturing errors, as found by tolerance analysis and by fabricating a prototype. Diamond micro-milling, a fabrication technique for lens array molds, was applied to plastic plano-concave and plano-convex lens arrays, and found to produce high quality optical surfaces. The micro-milling technique did not prove robust enough to produce bi-convex and meniscus lens arrays in a variety of lens shapes, however, and it required lengthy fabrication times. In order to rapidly prototype new lenses, a new diamond machining technique was

  16. Concurrent array-based queue

    Science.gov (United States)

    Heidelberger, Philip; Steinmacher-Burow, Burkhard

    2015-01-06

    According to one embodiment, a method for implementing an array-based queue in memory of a memory system that includes a controller includes configuring, in the memory, metadata of the array-based queue. The configuring comprises defining, in metadata, an array start location in the memory for the array-based queue, defining, in the metadata, an array size for the array-based queue, defining, in the metadata, a queue top for the array-based queue and defining, in the metadata, a queue bottom for the array-based queue. The method also includes the controller serving a request for an operation on the queue, the request providing the location in the memory of the metadata of the queue.

  17. Handy Microscopic Close-Range Videogrammetry

    Science.gov (United States)

    Esmaeili, F.; Ebadi, H.

    2017-09-01

    The modeling of small-scale objects is used in different applications such as medicine, industry, and cultural heritage. The capability of modeling small-scale objects using imaging with the help of hand USB digital microscopes and use of videogrammetry techniques has been implemented and evaluated in this paper. Use of this equipment and convergent imaging of the environment for modeling, provides an appropriate set of images for generation of three-dimensional models. The results of the measurements made with the help of a microscope micrometer calibration ruler have demonstrated that self-calibration of a hand camera-microscope set can help obtain a three-dimensional detail extraction precision of about 0.1 millimeters on small-scale environments.

  18. A two-dimensional Dirac fermion microscope

    Science.gov (United States)

    Bøggild, Peter; Caridad, José M.; Stampfer, Christoph; Calogero, Gaetano; Papior, Nick Rübner; Brandbyge, Mads

    2017-06-01

    The electron microscope has been a powerful, highly versatile workhorse in the fields of material and surface science, micro and nanotechnology, biology and geology, for nearly 80 years. The advent of two-dimensional materials opens new possibilities for realizing an analogy to electron microscopy in the solid state. Here we provide a perspective view on how a two-dimensional (2D) Dirac fermion-based microscope can be realistically implemented and operated, using graphene as a vacuum chamber for ballistic electrons. We use semiclassical simulations to propose concrete architectures and design rules of 2D electron guns, deflectors, tunable lenses and various detectors. The simulations show how simple objects can be imaged with well-controlled and collimated in-plane beams consisting of relativistic charge carriers. Finally, we discuss the potential of such microscopes for investigating edges, terminations and defects, as well as interfaces, including external nanoscale structures such as adsorbed molecules, nanoparticles or quantum dots.

  19. CHAMP (Camera, Handlens, and Microscope Probe)

    Science.gov (United States)

    Mungas, Greg S.; Boynton, John E.; Balzer, Mark A.; Beegle, Luther; Sobel, Harold R.; Fisher, Ted; Klein, Dan; Deans, Matthew; Lee, Pascal; Sepulveda, Cesar A.

    2005-01-01

    CHAMP (Camera, Handlens And Microscope Probe)is a novel field microscope capable of color imaging with continuously variable spatial resolution from infinity imaging down to diffraction-limited microscopy (3 micron/pixel). As a robotic arm-mounted imager, CHAMP supports stereo imaging with variable baselines, can continuously image targets at an increasing magnification during an arm approach, can provide precision rangefinding estimates to targets, and can accommodate microscopic imaging of rough surfaces through a image filtering process called z-stacking. CHAMP was originally developed through the Mars Instrument Development Program (MIDP) in support of robotic field investigations, but may also find application in new areas such as robotic in-orbit servicing and maintenance operations associated with spacecraft and human operations. We overview CHAMP'S instrument performance and basic design considerations below.

  20. CHAMP - Camera, Handlens, and Microscope Probe

    Science.gov (United States)

    Mungas, G. S.; Beegle, L. W.; Boynton, J.; Sepulveda, C. A.; Balzer, M. A.; Sobel, H. R.; Fisher, T. A.; Deans, M.; Lee, P.

    2005-01-01

    CHAMP (Camera, Handlens And Microscope Probe) is a novel field microscope capable of color imaging with continuously variable spatial resolution from infinity imaging down to diffraction-limited microscopy (3 micron/pixel). As an arm-mounted imager, CHAMP supports stereo-imaging with variable baselines, can continuously image targets at an increasing magnification during an arm approach, can provide precision range-finding estimates to targets, and can accommodate microscopic imaging of rough surfaces through a image filtering process called z-stacking. Currently designed with a filter wheel with 4 different filters, so that color and black and white images can be obtained over the entire Field-of-View, future designs will increase the number of filter positions to include 8 different filters. Finally, CHAMP incorporates controlled white and UV illumination so that images can be obtained regardless of sun position, and any potential fluorescent species can be identified so the most astrobiologically interesting samples can be identified.

  1. Smartphone Magnification Attachment: Microscope or Magnifying Glass

    Science.gov (United States)

    Hergemöller, Timo; Laumann, Daniel

    2017-09-01

    Today smartphones and tablets do not merely pervade our daily life, but also play a major role in STEM education in general, and in experimental investigations in particular. Enabling teachers and students to make use of these new techniques in physics lessons requires supplying capable and affordable applications. Our article presents the improvement of a low-cost technique turning smartphones into powerful magnifying glasses or microscopes. Adding only a 3D-printed clip attached to the smartphone's camera and inserting a small glass bead in this clip enables smartphones to take pictures with up to 780x magnification (see Fig. 1). In addition, the construction of the smartphone attachments helps to explain and examine the differences between magnifying glasses and microscopes, and shows that the widespread term "smartphone microscope" for this technique is inaccurate from a physics educational perspective.

  2. A two-dimensional Dirac fermion microscope.

    Science.gov (United States)

    Bøggild, Peter; Caridad, José M; Stampfer, Christoph; Calogero, Gaetano; Papior, Nick Rübner; Brandbyge, Mads

    2017-06-09

    The electron microscope has been a powerful, highly versatile workhorse in the fields of material and surface science, micro and nanotechnology, biology and geology, for nearly 80 years. The advent of two-dimensional materials opens new possibilities for realizing an analogy to electron microscopy in the solid state. Here we provide a perspective view on how a two-dimensional (2D) Dirac fermion-based microscope can be realistically implemented and operated, using graphene as a vacuum chamber for ballistic electrons. We use semiclassical simulations to propose concrete architectures and design rules of 2D electron guns, deflectors, tunable lenses and various detectors. The simulations show how simple objects can be imaged with well-controlled and collimated in-plane beams consisting of relativistic charge carriers. Finally, we discuss the potential of such microscopes for investigating edges, terminations and defects, as well as interfaces, including external nanoscale structures such as adsorbed molecules, nanoparticles or quantum dots.

  3. Radar techniques using array antennas

    CERN Document Server

    Wirth, Wulf-Dieter

    2013-01-01

    Radar Techniques Using Array Antennas is a thorough introduction to the possibilities of radar technology based on electronic steerable and active array antennas. Topics covered include array signal processing, array calibration, adaptive digital beamforming, adaptive monopulse, superresolution, pulse compression, sequential detection, target detection with long pulse series, space-time adaptive processing (STAP), moving target detection using synthetic aperture radar (SAR), target imaging, energy management and system parameter relations. The discussed methods are confirmed by simulation stud

  4. Development of an ultrasound microscope combined with optical microscope for multiparametric characterization of a single cell.

    Science.gov (United States)

    Arakawa, Mototaka; Shikama, Joe; Yoshida, Koki; Nagaoka, Ryo; Kobayashi, Kazuto; Saijo, Yoshifumi

    2015-09-01

    Biomechanics of the cell has been gathering much attention because it affects the pathological status in atherosclerosis and cancer. In the present study, an ultrasound microscope system combined with optical microscope for characterization of a single cell with multiple ultrasound parameters was developed. The central frequency of the transducer was 375 MHz and the scan area was 80 × 80 μm with up to 200 × 200 sampling points. An inverted optical microscope was incorporated in the design of the system, allowing for simultaneous optical observations of cultured cells. Two-dimensional mapping of multiple ultrasound parameters, such as sound speed, attenuation, and acoustic impedance, as well as the thickness, density, and bulk modulus of specimen/cell under investigation, etc., was realized by the system. Sound speed and thickness of a 3T3-L1 fibroblast cell were successfully obtained by the system. The ultrasound microscope system combined with optical microscope further enhances our understanding of cellular biomechanics.

  5. Case report: Pentoxifylline treatment in microscopic colitis.

    Science.gov (United States)

    Cotter, Thomas G; Kamboj, Amrit K; Hicks, Stephen Bradley; Tremaine, William J; Loftus, Edward V; Pardi, Darrell S

    2017-11-01

    Microscopic colitis is a common cause of diarrhea. Pentoxifylline, a xanthine derivative with anti-tumor necrosis factor-alpha properties, is prescribed for intermittent claudication and other disorders. Our goal was to evaluate the outcomes of patients with microscopic colitis treated with pentoxifylline. Nine patients with microscopic colitis (8 collagenous colitis and 1 lymphocytic colitis) seen at Mayo Clinic, Rochester, between January 1, 1997 and November 30, 2016, were included. The median age was 56.9 years (range 51.6-60.2), 8 were female (89%), and the median disease duration was 64.8 months (range 60-109). The indications for treatment were budesonide refractoriness in 7 patients, budesonide dependence in 1 patient, and budesonide intolerance in 1 patient. A histological diagnosis of microscopic colitis was confirmed in all patients. Pentoxifylline 400 mg three times a day was used for a median of 3 months (range 2.5-8.3). Complete response occurred in 1 patient (11%) and partial response in 3 patients (33%). The patient who achieved complete response was treated with pentoxifylline due to budesonide intolerance, and completed 43 months of successful maintenance therapy. There were no adverse effects reported. The majority of budesonide-experienced patients with active microscopic colitis did not respond to pentoxifylline. However, it was well-tolerated, with 1 patient achieving long-term remission and one-third of the cohort having a partial response. Larger controlled studies are required to evaluate the efficacy of pentoxifylline and predictors of response in microscopic colitis. In particular, patients who are not budesonide-refractory may be more likely to respond.

  6. Timed arrays wideband and time varying antenna arrays

    CERN Document Server

    Haupt, Randy L

    2015-01-01

    Introduces timed arrays and design approaches to meet the new high performance standards The author concentrates on any aspect of an antenna array that must be viewed from a time perspective. The first chapters briefly introduce antenna arrays and explain the difference between phased and timed arrays. Since timed arrays are designed for realistic time-varying signals and scenarios, the book also reviews wideband signals, baseband and passband RF signals, polarization and signal bandwidth. Other topics covered include time domain, mutual coupling, wideband elements, and dispersion. The auth

  7. Recurrent Memory Array Structures

    OpenAIRE

    Rocki, Kamil

    2016-01-01

    The following report introduces ideas augmenting standard Long Short Term Memory (LSTM) architecture with multiple memory cells per hidden unit in order to improve its generalization capabilities. It considers both deterministic and stochastic variants of memory operation. It is shown that the nondeterministic Array-LSTM approach improves state-of-the-art performance on character level text prediction achieving 1.402 BPC on enwik8 dataset. Furthermore, this report estabilishes baseline neural...

  8. Solar collector array

    Science.gov (United States)

    Hall, John Champlin; Martins, Guy Lawrence

    2015-09-06

    A method and apparatus for efficient manufacture, assembly and production of solar energy. In one aspect, the apparatus may include a number of modular solar receiver assemblies that may be separately manufactured, assembled and individually inserted into a solar collector array housing shaped to receive a plurality of solar receivers. The housing may include optical elements for focusing light onto the individual receivers, and a circuit for electrically connecting the solar receivers.

  9. The microscopic structure of the hydrogen liquids

    CERN Document Server

    Zoppi, M; Celli, M; Cuello, G J; Formisano, F; Guarini, E; Magli, R; Neumann, M

    2003-01-01

    We have measured the microscopic structure of liquid para-hydrogen by means of a neutron diffraction experiment on the D4C liquids diffractometer at Institute Laue-Langevin (Grenoble, France). This is the first direct neutron diffraction measurement of the static structure factor of hydrogen. The present determination of the microscopic structure of hydrogen is consistent with previous experimental determinations carried out on liquid deuterium and with path integral Monte Carlo simulations. The comparison with recent x-ray determinations is also satisfactory.

  10. An innovative approach in microscopic endodontics

    Science.gov (United States)

    Mittal, Sunandan; Kumar, Tarun; Sharma, Jyotika; Mittal, Shifali

    2014-01-01

    The introduction of the dental operating microscope was a turning point in the history of dentistry. It triggered a rapid transition from the conventional world of macro-dentistry to the precise, detailed world of micro-dentistry. However, working at these higher-power magnifications brings the clinician into the realm where even slight hand movements are disruptive. Physiologic hand tremor is a problem resulting in difficulty in mouth mirror placement. Hence, in this paper, a new instrument was designed to overcome the drawback of hand tremors during microscopic endodontics. PMID:24944459

  11. Three-dimensional positioning with optofluidic microscope

    DEFF Research Database (Denmark)

    Vig, Asger Laurberg; Marie, Rodolphe; Jensen, Eric

    2010-01-01

    This paper reports on-chip based optical detection with three-dimensional spatial resolution by integration of an optofluidic microscope (OFM) in a microfluidic pinched flow fractionation (PFF) separation device. This setup also enables on-chip particle image velocimetry (PIV). The position...... a conventional fluorescence microscope as readout. The size separated microspheres are detected by OFM with an accuracy of ≤ 0.92 μm. The position in the height of the channel and the velocity of the separated microspheres are detected with an accuracy of 1.4 μm and 0.08 mm/s respectively. Throughout...

  12. Optofluidic microscope with 3D spatial resolution

    DEFF Research Database (Denmark)

    Vig, Asger Laurberg; Marie, Rodolphe; Jensen, Eric

    2010-01-01

    This paper reports on-chip based optical detection with three-dimensional spatial resolution by integration of an optofluidic microscope (OFM) in a microfluidic pinched flow fractionation (PFF) separation device. This setup also enables on-chip particle image velocimetry (PIV). The position...... fluorescence microscope readout. The size separated microspheres are detected by OFM with an accuracy of ≤0.92μm. The position in the height of the channel and the velocity of the separated microspheres are detected with an accuracy of 1.4μm and 0.08 mm/s respectively. Throughout the measurements of the height...

  13. [Treatment of microscopic colitis - what's new?

    Science.gov (United States)

    Gonciarz, Maciej; Szkudłapski, Dawid; Eszyk, Jerzy; Smagacz, Justyna; Kopała, Marek

    2016-10-19

    Microscopic colitis (MC) is frequent, although still uncommonly diagnosed, cause of chronic diarrhea. The etiopathology of MC is unknown but this disease has strong influence on patient's quality of life (measured by health-related quality of life - HRQoL). MC is characterized by microscopic abnormalities in large bowel's mucosa whereas endoscopic and radiological examination findings are normal. The treatment of MC is an essential social and financial problem due to its frequency in society. Thanks to the results of some controlled research which judged efficiency of some medicines as well as advisory groups recommendations, the MC therapy is nowadays going from empiric to accordance with evidence based medicine.

  14. Scanning microscopic four-point conductivity probes

    DEFF Research Database (Denmark)

    Petersen, Christian Leth; Hansen, Torben Mikael; Bøggild, Peter

    2002-01-01

    the conducting material either for a silicon wafer or a single probe unit. Using shadow masking photolithography an electrode spacing (pitch) down to 1.1 mum was obtained, with cantilever separation down to 200 run. Characterisation measurements have shown the microscopic probes to be mechanically very flexible......A method for fabricating microscopic four-point probes is presented. The method uses silicon-based microfabrication technology involving only two patterning steps. The last step in the fabrication process is an unmasked deposition of the conducting probe material, and it is thus possible to select...

  15. Using a modified standard microscope to generate virtual slides.

    Science.gov (United States)

    Romer, David J; Yearsley, Kurtis H; Ayers, Leona W

    2003-05-01

    A standard microscope was reconfigured as a virtual slide generator by adding a Prior Scientific H101 robotic stage with H29 controller and 0.1 microm linear scales and a Hitachi HV-C20 3CCD camera. Media Cybernetics Image Pro Plus version 4 (IP4) software controlled stage movement in the X-, Y-, and Z-axis, whereas a Media Cybernetics Pro-Series Capture Kit captured images at 640 x 480 pixels. Stage calibration, scanning algorithms, storage requirements, and viewing modes were standardized. IP4 was used to montage the captured images into a large virtual slide image that was subsequently saved in TIF or JPEG format. Virtual slides were viewed at the workstation using the IP4 viewer as well as Adobe Photoshop and Kodak Imaging. MGI Zoom Server delivered the virtual slides to the Internet, and MicroBrightField's Neuroinformatica viewing software provided a browser-based virtual microscope interface together with labeling tools for annotating virtual slides. The images were served from a Windows 2000 platform with 2 GB RAM, 500 GB of disk storage, and a 1.0 GHz P4 processor. To conserve disk space on the image server, TIF files were converted to the FlashPix (FPX) file format using a compression ratio of 10:1. By using 4x, 10x, 20x, and 40x objectives, very large gigapixel images of tissue whole-mounts and tissue arrays with high quality and morphologic detail are now being generated for teaching, publication, research, and morphometric analysis. Technical details and a demonstration of our system can be found on the Web at http://virtualmicroscope.osu.edu. Copyright 2003 Wiley-Liss, Inc.

  16. Spaceborne Processor Array

    Science.gov (United States)

    Chow, Edward T.; Schatzel, Donald V.; Whitaker, William D.; Sterling, Thomas

    2008-01-01

    A Spaceborne Processor Array in Multifunctional Structure (SPAMS) can lower the total mass of the electronic and structural overhead of spacecraft, resulting in reduced launch costs, while increasing the science return through dynamic onboard computing. SPAMS integrates the multifunctional structure (MFS) and the Gilgamesh Memory, Intelligence, and Network Device (MIND) multi-core in-memory computer architecture into a single-system super-architecture. This transforms every inch of a spacecraft into a sharable, interconnected, smart computing element to increase computing performance while simultaneously reducing mass. The MIND in-memory architecture provides a foundation for high-performance, low-power, and fault-tolerant computing. The MIND chip has an internal structure that includes memory, processing, and communication functionality. The Gilgamesh is a scalable system comprising multiple MIND chips interconnected to operate as a single, tightly coupled, parallel computer. The array of MIND components shares a global, virtual name space for program variables and tasks that are allocated at run time to the distributed physical memory and processing resources. Individual processor- memory nodes can be activated or powered down at run time to provide active power management and to configure around faults. A SPAMS system is comprised of a distributed Gilgamesh array built into MFS, interfaces into instrument and communication subsystems, a mass storage interface, and a radiation-hardened flight computer.

  17. Solar array construction

    Science.gov (United States)

    Crouthamel, Marvin S.; Coyle, Peter J.

    1982-01-01

    An interconnect tab on each cell of a first set of circular solar cells connects that cell in series with an adjacent cell in the set. This set of cells is arranged in alternate columns and rows of an array and a second set of similar cells is arranged in the remaining alternate columns and rows of the array. Three interconnect tabs on each solar cell of the said second set are employed to connect the cells of the second set to one another, in series and to connect the cells of the second set to those of the first set in parallel. Some tabs (making parallel connections) connect the same surface regions of adjacent cells to one another and others (making series connections) connect a surface region of one cell to the opposite surface region of an adjacent cell; however, the tabs are so positioned that the array may be easily assembled by depositing the cells in a certain sequence and in proper orientation.

  18. Array processor architecture

    Science.gov (United States)

    Barnes, George H. (Inventor); Lundstrom, Stephen F. (Inventor); Shafer, Philip E. (Inventor)

    1983-01-01

    A high speed parallel array data processing architecture fashioned under a computational envelope approach includes a data base memory for secondary storage of programs and data, and a plurality of memory modules interconnected to a plurality of processing modules by a connection network of the Omega gender. Programs and data are fed from the data base memory to the plurality of memory modules and from hence the programs are fed through the connection network to the array of processors (one copy of each program for each processor). Execution of the programs occur with the processors operating normally quite independently of each other in a multiprocessing fashion. For data dependent operations and other suitable operations, all processors are instructed to finish one given task or program branch before all are instructed to proceed in parallel processing fashion on the next instruction. Even when functioning in the parallel processing mode however, the processors are not locked-step but execute their own copy of the program individually unless or until another overall processor array synchronization instruction is issued.

  19. Science 101: How Does an Electron Microscope Work?

    Science.gov (United States)

    Robertson, Bill

    2013-01-01

    Contrary to popular opinion, electron microscopes are not used to look at electrons. They are used to look for structure in things that are too small to observe with an optical microscope, or to obtain images that are magnified much more than is obtainable with an optical microscope. To understand how electron microscopes work, it will help to go…

  20. Integrated strain array for cellular mechanobiology studies

    Science.gov (United States)

    Simmons, C. S.; Sim, J. Y.; Baechtold, P.; Gonzalez, A.; Chung, C.; Borghi, N.; Pruitt, B. L.

    2011-05-01

    We have developed an integrated strain array for cell culture enabling high-throughput mechano-transduction studies. Biocompatible cell culture chambers were integrated with an acrylic pneumatic compartment and microprocessor-based control system. Each element of the array consists of a deformable membrane supported by a cylindrical pillar within a well. For user-prescribed waveforms, the annular region of the deformable membrane is pulled into the well around the pillar under vacuum, causing the pillar-supported region with cultured cells to be stretched biaxially. The optically clear device and pillar-based mechanism of operation enables imaging on standard laboratory microscopes. Straightforward fabrication utilizes off-the-shelf components, soft lithography techniques in polydimethylsiloxane and laser ablation of acrylic sheets. Proof of compatibility with basic biological assays and standard imaging equipment were accomplished by straining C2C12 skeletal myoblasts on the device for 6 h. At higher strains, cells and actin stress fibers realign with a circumferential preference.

  1. Setting up of holographic optical tweezer arrays

    Science.gov (United States)

    Gupta, Deepak K.; Tata, B. V. R.; Ravindran, T. R.

    2017-05-01

    Optical tweezers use tightly focused laser beams to hold and move microscopic objects in a solvent. However, many applications require simultaneous control over multitude of particles, positioning them in 3D space at desired locations with desired symmetry, which is made possible by the use of holographic optical tweezers using the technique of beam shaping and holography. We have designed and developed a holographic optical tweezer set-up using a phase only liquid crystal, reflective spatial light modulator. We employ the technique of phase modulation to modulate the phase of the beam by generating holograms using Random Superposition (RS) and weighted Gerchberg Saxton algorithm (WGS) algorithm for generating desired patterns of light at the trapping plane. A 4×4 array of beams with square symmetry was generated using WGS algorithm and trapped polystyrene particles of size 1.2 micron in a 4×4 two dimensional array. There were uniformity issues among the trap intensities, as we move away from the zeroth order spot. This was corrected by taking into account diffraction effects due to the pixelated nature of SLM modulating the intensity of the trap spots and the ghost order suppression by spatial disorder.

  2. Energy Management Programmes for Industry

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2012-09-05

    The IEA Policy Pathway publications provide details on how to implement specific recommendations drawn from the IEA 25 Energy Efficiency Policy Recommendations. This Policy Pathway, jointly produced by the International Energy Agency and the Institute for Industrial Productivity, develops the critical steps for policy makers implementing energy management programmes for industry. Optimising energy use in industry is essential to improve industrial competitiveness and achieve wider societal goals such as energy security, economic recovery and development, climate change mitigation and environmental protection. While there is significant potential to decrease energy consumption in this sector, opportunities to improve energy efficiency are still under-exploited. Energy management programmes have shown to be instrumental in addressing many of the barriers that inhibit wide-scale uptake of energy management in industry. The Policy Pathway builds on lessons learned from country experiences and provides actionable guidance on how to plan and design, implement, evaluate and monitor energy management programmes for industry.

  3. Spin microscope based on optically detected magnetic resonance

    Science.gov (United States)

    Berman, Gennady P.; Chernobrod, Boris M.

    2007-12-11

    The invention relates to scanning magnetic microscope which has a photoluminescent nanoprobe implanted in the tip apex of an atomic force microscope (AFM), a scanning tunneling microscope (STM) or a near-field scanning optical microscope (NSOM) and exhibits optically detected magnetic resonance (ODMR) in the vicinity of unpaired electron spins or nuclear magnetic moments in the sample material. The described spin microscope has demonstrated nanoscale lateral resolution and single spin sensitivity for the AFM and STM embodiments.

  4. Microscopic colitis: A review of etiology, treatment and refractory disease

    OpenAIRE

    Park, Tina; Cave, David; Marshall, Christopher

    2015-01-01

    Microscopic colitis is a common cause of chronic, nonbloody diarrhea. Microscopic colitis is more common in women than men and usually affects patients in their sixth and seventh decade. This article reviews the etiology and medical management of microscopic colitis. The etiology of microscopic colitis is unknown, but it is associated with autoimmune disorders, such as celiac disease, polyarthritis, and thyroid disorders. Smoking has been identified as a risk factor of microscopic colitis. Ex...

  5. African Astronomy and the Square Kilometre Array

    Science.gov (United States)

    MacLeod, Gordon

    2010-02-01

    We highlight the growth of astronomy across Africa and the effect of hosting the Square Kilometer Array (SKA) will have on this growth. From the construction of a new 25m radio telescope in Nigeria, to new university astronomy programmes in Kenya, the HESS in Namibia and the Mauritian Radio Telescope, to the world class projects being developed in South Africa (Southern African Large Telescope and Karoo Array Telescope) astronomy is re-emerging across the continent. The SKA will represent the pinnacle of technological advancement in astronomy when constructed; requiring ultra high speed data transmission lines over 3000 km baselines and the World's fastest computer for correlation purposes. The investment alone to build the SKA on African soil will be of great economic benefit to its people, but the required network connectivity will significantly drive commercial expansion far beyond the initial value of the SKA investment. The most important consequence of hosting the SKA in Africa would be the impact on Human Capital Development (HCD) on the continent. Major HCD projects already underway producing excellent results will be presented. )

  6. Optimizing cell arrays for accurate functional genomics.

    Science.gov (United States)

    Fengler, Sven; Bastiaens, Philippe I H; Grecco, Hernán E; Roda-Navarro, Pedro

    2012-07-17

    Cellular responses emerge from a complex network of dynamic biochemical reactions. In order to investigate them is necessary to develop methods that allow perturbing a high number of gene products in a flexible and fast way. Cell arrays (CA) enable such experiments on microscope slides via reverse transfection of cellular colonies growing on spotted genetic material. In contrast to multi-well plates, CA are susceptible to contamination among neighboring spots hindering accurate quantification in cell-based screening projects. Here we have developed a quality control protocol for quantifying and minimizing contamination in CA. We imaged checkered CA that express two distinct fluorescent proteins and segmented images into single cells to quantify the transfection efficiency and interspot contamination. Compared with standard procedures, we measured a 3-fold reduction of contaminants when arrays containing HeLa cells were washed shortly after cell seeding. We proved that nucleic acid uptake during cell seeding rather than migration among neighboring spots was the major source of contamination. Arrays of MCF7 cells developed without the washing step showed 7-fold lower percentage of contaminant cells, demonstrating that contamination is dependent on specific cell properties. Previously published methodological works have focused on achieving high transfection rate in densely packed CA. Here, we focused in an equally important parameter: The interspot contamination. The presented quality control is essential for estimating the rate of contamination, a major source of false positives and negatives in current microscopy based functional genomics screenings. We have demonstrated that a washing step after seeding enhances CA quality for HeLA but is not necessary for MCF7. The described method provides a way to find optimal seeding protocols for cell lines intended to be used for the first time in CA.

  7. Optimizing cell arrays for accurate functional genomics

    Directory of Open Access Journals (Sweden)

    Fengler Sven

    2012-07-01

    Full Text Available Abstract Background Cellular responses emerge from a complex network of dynamic biochemical reactions. In order to investigate them is necessary to develop methods that allow perturbing a high number of gene products in a flexible and fast way. Cell arrays (CA enable such experiments on microscope slides via reverse transfection of cellular colonies growing on spotted genetic material. In contrast to multi-well plates, CA are susceptible to contamination among neighboring spots hindering accurate quantification in cell-based screening projects. Here we have developed a quality control protocol for quantifying and minimizing contamination in CA. Results We imaged checkered CA that express two distinct fluorescent proteins and segmented images into single cells to quantify the transfection efficiency and interspot contamination. Compared with standard procedures, we measured a 3-fold reduction of contaminants when arrays containing HeLa cells were washed shortly after cell seeding. We proved that nucleic acid uptake during cell seeding rather than migration among neighboring spots was the major source of contamination. Arrays of MCF7 cells developed without the washing step showed 7-fold lower percentage of contaminant cells, demonstrating that contamination is dependent on specific cell properties. Conclusions Previously published methodological works have focused on achieving high transfection rate in densely packed CA. Here, we focused in an equally important parameter: The interspot contamination. The presented quality control is essential for estimating the rate of contamination, a major source of false positives and negatives in current microscopy based functional genomics screenings. We have demonstrated that a washing step after seeding enhances CA quality for HeLA but is not necessary for MCF7. The described method provides a way to find optimal seeding protocols for cell lines intended to be used for the first time in CA.

  8. MACROSCOPICAL AND MICROSCOPICAL STUDIES ON THE ...

    African Journals Online (AJOL)

    Caesalpinia crista leaves are bipinnate of about six pairs with alternate leaflets while the stem us fibrous, cylindrical hollow and prickly. Microscopical examination revealed the presence of strained cuticle, straight-walled epidermal cells, paracytic stomata, unicellular covering trichomes, fibres, prisms as well as cluster of ...

  9. Fiber coupled ultrafast scanning tunneling microscope

    DEFF Research Database (Denmark)

    Keil, Ulrich Dieter Felix; Jensen, Jacob Riis; Hvam, Jørn Märcher

    1997-01-01

    We report on a scanning tunneling microscope with a photoconductive gate in the tunneling current circuit. The tunneling tip is attached to a coplanar transmission line with an integrated photoconductive switch. The switch is illuminated through a fiber which is rigidly attached to the switch...

  10. Compact, common path quantitative phase microscopic techniques ...

    Indian Academy of Sciences (India)

    2014-01-05

    Jan 5, 2014 ... One of the ways to retrieve object height/thickness information is to employ quantitative phase microscopic (QPM) techniques. Interferometric QPM techniques are widely used for this. Digital holographic microscopy (DHM) is one of the stateof-the-art methods for quantitative three-dimensional (3D) imaging.

  11. Leptospirosis serodiagnosis by the microscopic agglutination test

    NARCIS (Netherlands)

    Goris, Marga G. A.; Hartskeerl, Rudy A.

    2014-01-01

    The microscopic agglutination test (MAT) is the gold standard for sero-diagnosis of leptospirosis because of its unsurpassed diagnostic specificity. It uses panels of live leptospires, ideally recent isolates, representing the circulating serovars from the area where the patient became infected. A

  12. Stick-on microscope for smartphones

    Science.gov (United States)

    Lee, W. M.

    2014-02-01

    In this paper, I demonstrate a low cost light weight microscope device that is compatible with any smartphone camera. The device amplifies the imaging resolution of a smartphone camera by three orders of magnitude from millimeters to sub-micrometers, while costing approximately USD$ 2.

  13. Of Mechanisms, Microscopes and Methyl isocyanate

    Indian Academy of Sciences (India)

    Home; Journals; Resonance – Journal of Science Education; Volume 13; Issue 3. Of Mechanisms, Microscopes and Methyl isocyanate. S Sriramachari Sujata Varadarajan. Face to Face Volume 13 Issue 3 March 2008 pp 292-306. Fulltext. Click here to view fulltext PDF. Permanent link:

  14. Wavelet Transform-A New Mathematical Microscope

    Indian Academy of Sciences (India)

    Home; Journals; Resonance – Journal of Science Education; Volume 9; Issue 3. Wavelet Transform - A New Mathematical Microscope. Sachin P Nanavati Prasanta K Panigrahi. General Article Volume 9 Issue 3 March 2004 pp 50-64. Fulltext. Click here to view fulltext PDF. Permanent link:

  15. Vibrational spectroscopy in the electron microscope.

    Science.gov (United States)

    Krivanek, Ondrej L; Lovejoy, Tracy C; Dellby, Niklas; Aoki, Toshihiro; Carpenter, R W; Rez, Peter; Soignard, Emmanuel; Zhu, Jiangtao; Batson, Philip E; Lagos, Maureen J; Egerton, Ray F; Crozier, Peter A

    2014-10-09

    Vibrational spectroscopies using infrared radiation, Raman scattering, neutrons, low-energy electrons and inelastic electron tunnelling are powerful techniques that can analyse bonding arrangements, identify chemical compounds and probe many other important properties of materials. The spatial resolution of these spectroscopies is typically one micrometre or more, although it can reach a few tens of nanometres or even a few ångströms when enhanced by the presence of a sharp metallic tip. If vibrational spectroscopy could be combined with the spatial resolution and flexibility of the transmission electron microscope, it would open up the study of vibrational modes in many different types of nanostructures. Unfortunately, the energy resolution of electron energy loss spectroscopy performed in the electron microscope has until now been too poor to allow such a combination. Recent developments that have improved the attainable energy resolution of electron energy loss spectroscopy in a scanning transmission electron microscope to around ten millielectronvolts now allow vibrational spectroscopy to be carried out in the electron microscope. Here we describe the innovations responsible for the progress, and present examples of applications in inorganic and organic materials, including the detection of hydrogen. We also demonstrate that the vibrational signal has both high- and low-spatial-resolution components, that the first component can be used to map vibrational features at nanometre-level resolution, and that the second component can be used for analysis carried out with the beam positioned just outside the sample--that is, for 'aloof' spectroscopy that largely avoids radiation damage.

  16. Exploring the environmental transmission electron microscope

    DEFF Research Database (Denmark)

    Wagner, Jakob B.; Cavalca, Filippo; Damsgaard, Christian D.

    2012-01-01

    of the opportunities that the environmental TEM (ETEM) offers when combined with other in situ techniques will be explored, directly in the microscope, by combining electron-based and photon-based techniques and phenomena. In addition, application of adjacent setups using sophisticated transfer methods...

  17. Nanofabrication with a helium ion microscope

    NARCIS (Netherlands)

    Maas, D.; Van Veldhoven, E.; Chen, P.; Sidorkin, V.; Salemink, H.; Van der Drift, E.; Alkemade, P.

    2009-01-01

    The recently introduced helium ion microscope (HIM) is capable of imaging and fabrication of nanostructures thanks to its sub-nanometer sized ion probe [1,2]. The unique interaction of the helium ions with the sample material provides very localized secondary electron emission, thus providing a

  18. Microscopic tunneling theory of long Josephson junctions

    DEFF Research Database (Denmark)

    Grønbech-Jensen, N.; Hattel, Søren A.; Samuelsen, Mogens Rugholm

    1992-01-01

    We present a numerical scheme for solving a nonlinear partial integro-differential equation with nonlocal time dependence. The equation describes the dynamics in a long Josephson junction modeled by use of the microscopic theory for tunneling between superconductors. We demonstrate...

  19. Reasoning about Magnetism at the Microscopic Level

    Science.gov (United States)

    Cheng, Meng-Fei; Cheng, Yufang; Hung, Shuo-Hsien

    2014-01-01

    Based on our experience of teaching physics in middle and senior secondary school, we have found that students have difficulty in reasoning at the microscopic level. Their reasoning is limited to the observational level so they have problems in developing scientific models of magnetism. Here, we suggest several practical activities and the use of…

  20. Optical phase images of living microscopic objects

    Science.gov (United States)

    Tychinsky, Vladimir P.; Norina, Svetlana B.; Odintsov, Alex; Popp, Fritz A.; Vyshenskaia, Tatiana V.

    1994-02-01

    Some living biological objects were investigated with `AiryScan'-computer-aided Phase Microscope with spatial resolution up to 0.05 micrometers and time resolution 1 ms. Influence of ATP on the frequency and intensity of Infusoria Paramecium Caudatum and Unio pictorium cilia beat were observed.

  1. A two-dimensional Dirac fermion microscope

    DEFF Research Database (Denmark)

    Bøggild, Peter; Caridad, Jose; Stampfer, Christoph

    2017-01-01

    D electron guns, deflectors, tunable lenses and various detectors. The simulations show how simple objects can be imaged with well-controlled and collimated in-plane beams consisting of relativistic charge carriers. Finally, we discuss the potential of such microscopes for investigating edges...

  2. Microscopic Derivation of Ginzburg-Landau Theory

    DEFF Research Database (Denmark)

    Frank, Rupert; Hainzl, Christian; Seiringer, Robert

    2012-01-01

    We give the first rigorous derivation of the celebrated Ginzburg-Landau (GL) theory, starting from the microscopic Bardeen-Cooper-Schrieffer (BCS) model. Close to the critical temperature, GL arises as an effective theory on the macroscopic scale. The relevant scaling limit is semiclassical...

  3. Microscopic TV shearography for characterization of microsystems.

    Science.gov (United States)

    Paul Kumar, U; Kothiyal, M P; Mohan, N Krishna

    2009-05-15

    We demonstrate a microscopic TV shearographic configuration for characterization of microsystems by measuring the slope under relatively large out-of-plane deformation. In the optical arrangement, a long working distance zoom imaging system is combined with a conventional Michelson shear interferometer. The experimental results on a microelectromechanical system pressure sensor subjected to external pressure load are presented.

  4. The need for theory evaluation in global citizenship programmes: The case of the GCSA programme.

    Science.gov (United States)

    Goodier, Sarah; Field, Carren; Goodman, Suki

    2018-02-01

    Many education programmes lack a documented programme theory. This is a problem for programme planners and evaluators as the ability to measure programme success is grounded in the plausibility of the programme's underlying causal logic. Where the programme theory has not been documented, conducting a theory evaluation offers a foundational evaluation step as it gives an indication of whether the theory behind a programme is sound. This paper presents a case of a theory evaluation of a Global Citizenship programme at a top-ranking university in South Africa, subsequently called the GCSA Programme. This evaluation highlights the need for documented programme theory in global citizenship-type programmes for future programme development. An articulated programme theory produced for the GCSA Programme, analysed against the available social science literature, indicated it is comparable to other such programmes in terms of its overarching framework. What the research found is that most other global citizenship programmes do not have an articulated programme theory. These programmes also do not explicitly link their specific activities to their intended outcomes, making demonstrating impact impossible. In conclusion, we argue that taking a theory-based approach can strengthen and enable outcome evaluations in global citizenship programmes. Copyright © 2017. Published by Elsevier Ltd.

  5. Nitrogen-doped carbon nanotube arrays grown on graphene substrate

    Energy Technology Data Exchange (ETDEWEB)

    Li Xun [State Key Laboratory of Coordination Chemistry, Nanjing National Laboratory of Microstructure, School of Chemistry and Chemical Engineering, Nanjing University, Nanjing, 210093 (China); State Key Laboratory of Soil and Sustainable Agriculture, Institute of Soil Science, Chinese Academy of Sciences, Nanjing, 210008 (China); Zhu Guoxing [State Key Laboratory of Coordination Chemistry, Nanjing National Laboratory of Microstructure, School of Chemistry and Chemical Engineering, Nanjing University, Nanjing, 210093 (China); Xu Zheng, E-mail: zhengxu@nju.edu.cn [State Key Laboratory of Coordination Chemistry, Nanjing National Laboratory of Microstructure, School of Chemistry and Chemical Engineering, Nanjing University, Nanjing, 210093 (China)

    2012-01-01

    Nitrogen-doped carbon nanotube (N-doped CNT) arrays have been synthesized on graphene substrate by chemical vapor deposition process, in which iron nanoparticles (NPs) assembled on the graphene sheet were generated in situ from the reduction of Fe{sub 3}O{sub 4} NPs/reduced graphene oxide (RGO) and were used as catalyst. The morphology and structure of the N-doped CNT arrays were investigated by field emission scanning electron microscope and high-resolution transmission electron microscope. The N-doped CNTs were bamboo-shaped and the density can be controlled by modulating the density of catalyst NPs on RGO sheets. The concentration and incorporation of nitrogen were studied by elemental analysis, X-ray photoelectron spectroscope and Raman analysis, and the results showed that the nitrogen content was around 3 wt.%. Because of the good conductivity of graphene structure, N-doped CNT arrays grown on graphene substrate may be promising candidates as noble metal-free electrodes for oxygen reduction reaction in the future.

  6. The IMPACT Common Module - A Low Cost, Reconfigurable Building Block for Next Generation Phased Arrays

    Science.gov (United States)

    2016-03-31

    of Oklahoma Advanced Radar Research Center (ARRC), 3190 Monitor Ave, Norman, OK USA 73019 Boris Murmann, Bill Chen, Alex Guo Dept. of...These are optimized to run on medium grade Field Programmable Gate Arrays (FPGAs), such as the Altera Arria 10, and represent a few of the many

  7. Large micro-mirror arrays: key components in future space instruments for Universe and Earth Observation

    Directory of Open Access Journals (Sweden)

    Zamkotsian Frederic

    2015-01-01

    Full Text Available In future space missions for Universe and Earth Observation, scientific return could be optimized using MOEMS devices. Micro-mirror arrays are used for designing new generation of instruments, multi-object spectrographs in Universe Observation and programmable wide field spectrographs in Earth Observation. Mock-ups have been designed and built for both applications and they show very promising results.

  8. Efficient processing of two-dimensional arrays with C or C++

    Science.gov (United States)

    Donato, David I.

    2017-07-20

    Because fast and efficient serial processing of raster-graphic images and other two-dimensional arrays is a requirement in land-change modeling and other applications, the effects of 10 factors on the runtimes for processing two-dimensional arrays with C and C++ are evaluated in a comparative factorial study. This study’s factors include the choice among three C or C++ source-code techniques for array processing; the choice of Microsoft Windows 7 or a Linux operating system; the choice of 4-byte or 8-byte array elements and indexes; and the choice of 32-bit or 64-bit memory addressing. This study demonstrates how programmer choices can reduce runtimes by 75 percent or more, even after compiler optimizations. Ten points of practical advice for faster processing of two-dimensional arrays are offered to C and C++ programmers. Further study and the development of a C and C++ software test suite are recommended.Key words: array processing, C, C++, compiler, computational speed, land-change modeling, raster-graphic image, two-dimensional array, software efficiency

  9. Characterization of Electron Microscopes with Binary Pseudo-random Multilayer Test Samples

    Energy Technology Data Exchange (ETDEWEB)

    V Yashchuk; R Conley; E Anderson; S Barber; N Bouet; W McKinney; P Takacs; D Voronov

    2011-12-31

    Verification of the reliability of metrology data from high quality X-ray optics requires that adequate methods for test and calibration of the instruments be developed. For such verification for optical surface profilometers in the spatial frequency domain, a modulation transfer function (MTF) calibration method based on binary pseudo-random (BPR) gratings and arrays has been suggested [1] and [2] and proven to be an effective calibration method for a number of interferometric microscopes, a phase shifting Fizeau interferometer, and a scatterometer [5]. Here we describe the details of development of binary pseudo-random multilayer (BPRML) test samples suitable for characterization of scanning (SEM) and transmission (TEM) electron microscopes. We discuss the results of TEM measurements with the BPRML test samples fabricated from a WiSi2/Si multilayer coating with pseudo-randomly distributed layers. In particular, we demonstrate that significant information about the metrological reliability of the TEM measurements can be extracted even when the fundamental frequency of the BPRML sample is smaller than the Nyquist frequency of the measurements. The measurements demonstrate a number of problems related to the interpretation of the SEM and TEM data. Note that similar BPRML test samples can be used to characterize X-ray microscopes. Corresponding work with X-ray microscopes is in progress.

  10. Characterization of electron microscopes with binary pseudo-random multilayer test samples

    Energy Technology Data Exchange (ETDEWEB)

    Yashchuk, Valeriy V., E-mail: VVYashchuk@lbl.gov [Advanced Light Source, Lawrence Berkeley National Laboratory, Berkeley, CA 94720 (United States); Conley, Raymond [NSLS-II, Brookhaven National Laboratory, Upton, NY 11973 (United States); Anderson, Erik H. [Center for X-ray Optics, Lawrence Berkeley National Laboratory, Berkeley, CA 94720 (United States); Barber, Samuel K. [Advanced Light Source, Lawrence Berkeley National Laboratory, Berkeley, CA 94720 (United States); Bouet, Nathalie [NSLS-II, Brookhaven National Laboratory, Upton, NY 11973 (United States); McKinney, Wayne R. [Advanced Light Source, Lawrence Berkeley National Laboratory, Berkeley, CA 94720 (United States); Takacs, Peter Z. [Brookhaven National Laboratory, Upton, NY 11973 (United States); Voronov, Dmitriy L. [Advanced Light Source, Lawrence Berkeley National Laboratory, Berkeley, CA 94720 (United States)

    2011-09-01

    Verification of the reliability of metrology data from high quality X-ray optics requires that adequate methods for test and calibration of the instruments be developed. For such verification for optical surface profilometers in the spatial frequency domain, a modulation transfer function (MTF) calibration method based on binary pseudo-random (BPR) gratings and arrays has been suggested and proven to be an effective calibration method for a number of interferometric microscopes, a phase shifting Fizeau interferometer, and a scatterometer [5]. Here we describe the details of development of binary pseudo-random multilayer (BPRML) test samples suitable for characterization of scanning (SEM) and transmission (TEM) electron microscopes. We discuss the results of TEM measurements with the BPRML test samples fabricated from a WiSi{sub 2}/Si multilayer coating with pseudo-randomly distributed layers. In particular, we demonstrate that significant information about the metrological reliability of the TEM measurements can be extracted even when the fundamental frequency of the BPRML sample is smaller than the Nyquist frequency of the measurements. The measurements demonstrate a number of problems related to the interpretation of the SEM and TEM data. Note that similar BPRML test samples can be used to characterize X-ray microscopes. Corresponding work with X-ray microscopes is in progress.

  11. UAVSAR Phased Array Aperture

    Science.gov (United States)

    Chamberlain, Neil; Zawadzki, Mark; Sadowy, Greg; Oakes, Eric; Brown, Kyle; Hodges, Richard

    2009-01-01

    This paper describes the development of a patch antenna array for an L-band repeat-pass interferometric synthetic aperture radar (InSAR) instrument that is to be flown on an unmanned aerial vehicle (UAV). The antenna operates at a center frequency of 1.2575 GHz and with a bandwidth of 80 MHz, consistent with a number of radar instruments that JPL has previously flown. The antenna is designed to radiate orthogonal linear polarizations in order to facilitate fully-polarimetric measurements. Beam-pointing requirements for repeat-pass SAR interferometry necessitate electronic scanning in azimuth over a range of -20degrees in order to compensate for aircraft yaw. Beam-steering is accomplished by transmit/receive (T/R) modules and a beamforming network implemented in a stripline circuit board. This paper, while providing an overview of phased array architecture, focuses on the electromagnetic design of the antenna tiles and associated interconnects. An important aspect of the design of this antenna is that it has an amplitude taper of 10dB in the elevation direction. This is to reduce multipath reflections from the wing that would otherwise be detrimental to interferometric radar measurements. This taper is provided by coupling networks in the interconnect circuits as opposed to attenuating the output of the T/R modules. Details are given of material choices and fabrication techniques that meet the demanding environmental conditions that the antenna must operate in. Predicted array performance is reported in terms of co-polarized and crosspolarized far-field antenna patterns, and also in terms of active reflection coefficient.

  12. Fabrication of core-shell micro/nanoparticles for programmable dual drug release by emulsion electrospraying

    Energy Technology Data Exchange (ETDEWEB)

    Wang Yazhou, E-mail: yazhou_wang@cqu.edu.cn; Zhang Yiqiong; Wang Bochu, E-mail: wangbc2000@126.com; Cao Yang [Chongqing University, Key Laboratory of Biorheological Science and Technology, Ministry of Education, College of Bioengineering (China); Yu Qingsong [University of Missouri, Department of Mechanical and Aerospace Engineering (United States); Yin Tieying [Chongqing University, Key Laboratory of Biorheological Science and Technology, Ministry of Education, College of Bioengineering (China)

    2013-06-15

    The study aimed at constructing a novel drug delivery system for programmable multiple drug release controlled with core-shell structure. The core-shell structure consisted of chitosan nanoparticles as core and polyvinylpyrrolidone micro/nanocoating as shell to form core-shell micro/nanoparticles, which was fabricated by ionic gelation and emulsion electrospray methods. As model drug agents, Naproxen and rhodamine B were encapsulated in the core and shell regions, respectively. The core-shell micro/nanoparticles thus fabricated were characterized and confirmed by scanning electron microscope, transmission electron microscope, and fluorescence optical microscope. The core-shell micro/nanoparticles showed good release controllability through drug release experiment in vitro. It was noted that a programmable release pattern for dual drug agents was also achieved by adjusting their loading regions in the core-shell structures. The results indicate that emulsion electrospraying technology is a promising approach in fabrication of core-shell micro/nanoparticles for programmable dual drug release. Such a novel multi-drug delivery system has a potential application for the clinical treatment of cancer, tuberculosis, and tissue engineering.

  13. Magnetomicrofluidics Circuits for Organizing Bioparticle Arrays

    Science.gov (United States)

    Abedini-Nassab, Roozbeh

    Single-cell analysis (SCA) tools have important applications in the analysis of phenotypic heterogeneity, which is difficult or impossible to analyze in bulk cell culture or patient samples. SCA tools thus have a myriad of applications ranging from better credentialing of drug therapies to the analysis of rare latent cells harboring HIV infection or in Cancer. However, existing SCA systems usually lack the required combination of programmability, flexibility, and scalability necessary to enable the study of cell behaviors and cell-cell interactions at the scales sufficient to analyze extremely rare events. To advance the field, I have developed a novel, programmable, and massively-parallel SCA tool which is based on the principles of computer circuits. By integrating these magnetic circuits with microfluidics channels, I developed a platform that can organize a large number of single particles into an array in a controlled manner. My magnetophoretic circuits use passive elements constructed in patterned magnetic thin films to move cells along programmed tracks with an external rotating magnetic field. Cell motion along these tracks is analogous to the motion of charges in an electrical conductor, following a rule similar to Ohm's law. I have also developed asymmetric conductors, similar to electrical diodes, and storage sites for cells that behave similarly to electrical capacitors. I have also developed magnetophoretic circuits which use an overlaid pattern of microwires to switch single cells between different tracks. This switching mechanism, analogous to the operation of electronic transistors, is achieved by establishing a semiconducting gap in the magnetic pattern which can be changed from an insulating state to a conducting state by application of electrical current to an overlaid electrode. I performed an extensive study on the operation of transistors to optimize their geometry and minimize the required gate currents. By combining these elements into

  14. The internationalisation of postgraduate programmes

    DEFF Research Database (Denmark)

    Fink, Flemming Kobberøe; Andersen, Ole K.; Bak, Thomas

    2002-01-01

    This paper presents the efforts and experiences of globalisation of the study programmes within electronic engineering at Aalborg University. The Project-Organised Problem-Based Learning Model, which have been employed since 1974 is presented and discussed. The consequences this has for the inter...

  15. Portugal's Secondary School Modernisation Programme

    Science.gov (United States)

    Heitor, Teresa V.; Freire da Silva, Jose M. R.

    2009-01-01

    The aim of the Secondary School Modernisation Programme, being implemented in Portugal by "Parque Escolar, EPE", is based on the pursuit of quality and makes Portuguese education a potential international benchmark. This paper discusses the strategies adopted to reorganise school spaces. It describes the conceptual model and highlights…

  16. Indico CONFERENCE: Define the Programme

    CERN Multimedia

    CERN. Geneva; Ferreira, Pedro

    2017-01-01

    In this tutorial you are going to learn how to define the programme of a conference in Indico. The program of your conference is divided in different “tracks”. Tracks represent the subject matter of the conference, such as “Online Computing”, “Offline Computing”, and so on.

  17. Planetary Sciences and Exploration Programme

    Indian Academy of Sciences (India)

    The Indian Space Research Organisation (ISRO) has taken a number of initiatives to plan for a National. Research Programme in the area of planetary science and exploration. This announcement solicits proposals in the field of planetary science. Universities, research and educational institutions may submit proposals ...

  18. Final Draft Programme Support Document

    DEFF Research Database (Denmark)

    Enemark, Ulrika; Schleimann, Finn; Vagnby, Bo Hellisen

    The HSPS III is the third phase of Danish support to the Ghanaian Health Sector. The support is in line with the Ministy of Health's Medium Term Strategy and the Second Five-Year Programme of Work; the latter also bring in line with the Ghana Poverty Reduction Strategy. The majority of funds (340...

  19. Abandoning weight-loss programmes

    African Journals Online (AJOL)

    the weight-loss programme. The facilitator of the discu.ssion groups, a clinical psychologist, asked only non-directive ques- tions and ensured participation of all members in the group. For every 4 panicipants a silent and non-panicipant observer recorded contributions. Group members formed a circle and silent observers ...

  20. The Johannesburg cardiac rehabilitation programme

    African Journals Online (AJOL)

    1991-02-16

    Feb 16, 1991 ... luminal coronary angioplasty (PTCA), and those with chronic stable angina); (il) patients with major coronary risk factors only; and (iil) patients who had undergone surgery for valvular or congenital heart disease. Initial evaluation. On admission to the programme all patients underwent a full medical ...

  1. Studying programme in confrontational introspection

    Directory of Open Access Journals (Sweden)

    Rudolf Šrámek

    2004-01-01

    Full Text Available Confrontation of first two and meanwhile last two studying programmes proves that there was devoted more hours for teaching – relationship between range of lectures and seminars with practices was 1:1. There was defined approximately 10% more of time than nowadays for stay of students in practices schools.

  2. Marine line fish research programme

    CSIR Research Space (South Africa)

    SANCOR

    1979-04-01

    Full Text Available This report outlines the framework for a marine line fish programme under the aegis of the South African National Committee for Oceanographic Research (SANCOR). An attempt is made to assess the state of knowledge about South African marine line...

  3. The Massey Kiwi Friend Programme

    Science.gov (United States)

    Ramsey, Philip; Ramsey, Deborah; Mason, Robyn

    2007-01-01

    Like many institutions, Massey University has experienced growth in enrolments of international students. Increasing numbers of international students has led to frustrations for international and domestic students, and for staff. This paper describes an innovative programme designed to help with the orientation of international students. Domestic…

  4. ARUSHA SCHOOL DENTAL HEALTH PROGRAMME

    African Journals Online (AJOL)

    ARUSHA SCHOOL DENTAL HEALTH. PROGRAMME. Dr. MOSHA H. T. Senior Dental Surgeon,. Ministry of Health, Dar es Salaam. DESCRIPTION OF THE DISTRICT. Arusha District is one of the 6 districts of. Aruska region. It consists of an urban part and a suburban part. Arusha Town has a population of. 88155 people ...

  5. The Johannesburg cardiac rehabilitation programme

    African Journals Online (AJOL)

    1991-02-16

    Feb 16, 1991 ... Cardiac rehabilitation, including supervised exercise therapy, has become a generally accepted mode of ... the effects of a combined health education and exercise training programme on these patients' ..... when exercise training was combined with body weight loss. It has also recently been suggested ...

  6. Fast reactor programme in India

    Indian Academy of Sciences (India)

    2015-09-04

    Sep 4, 2015 ... Home; Journals; Pramana – Journal of Physics; Volume 85; Issue 3. Fast reactor programme in India. P Chellapandi P R ... Keywords. Sodium fast reactor; design challenges; construction challenges; emerging safety criteria; passive shutdown and decay heat removal systems; fast breeder reactors in India.

  7. Summer Student Programme – Report

    CERN Document Server

    Bellora, Andrea

    2016-01-01

    This is the report on the studies about radiation damage on silicon strips detectors I've performed during my Summer Student Programme. A parameter to describe the damage amount has been defined, as well as his behaviour over time and absorbed dose.

  8. A synchronous serial bus for multidimensional array acoustic logging tool

    Science.gov (United States)

    Men, Baiyong; Ju, Xiaodong; Lu, Junqiang; Qiao, Wenxiao

    2016-12-01

    In high-temperature and spatial borehole applications, a distributed structure is employed in a multidimensional array acoustic logging tool (MDALT) based on a phased array technique for electronic systems. However, new challenges, such as synchronous multichannel data acquisition, multinode real-time control and bulk data transmission in a limited interval, have emerged. To address these challenges, we developed a synchronous serial bus (SSB) in this study. SSB works in a half-duplex mode via a master-slave architecture. It also consists of a single master, several slaves, a differential clock line and a differential data line. The clock line is simplex, whereas the data line is half-duplex and synchronous to the clock line. A reliable communication between the master and the slaves with real-time adjustment of synchronisation is achieved by rationally designing the frame format and protocol of communication and by introducing a scramble code and a Hamming error-correcting code. The control logic of the master and the slaves is realized in field programmable gate array (FPGA) or complex programmable logic device (CPLD). The clock speed of SSB is 10 MHz, the effective data rate of the bulk data transmission is over 99%, and the synchronous errors amongst the slaves are less than 10 ns. Room-temperature test, high-temperature test (175 °C) and field test demonstrate that the proposed SSB is qualified for MDALT.

  9. A Lambda Calculus for Transfinite Arrays: Unifying Arrays and Streams

    OpenAIRE

    Sinkarovs, Artjoms; Scholz, Sven-Bodo

    2017-01-01

    Array programming languages allow for concise and generic formulations of numerical algorithms, thereby providing a huge potential for program optimisation such as fusion, parallelisation, etc. One of the restrictions that these languages typically have is that the number of elements in every array has to be finite. This means that implementing streaming algorithms in such languages requires new types of data structures, with operations that are not immediately compatible with existing array ...

  10. Using aberration test patterns to optimize the performance of EUV aerial imaging microscopes

    Energy Technology Data Exchange (ETDEWEB)

    Mochi, Iacopo; Goldberg, Kenneth A.; Miyakawa, Ryan; Naulleau, Patrick; Han, Hak-Seung; Huh, Sungmin

    2009-06-16

    The SEMATECH Berkeley Actinic Inspection Tool (AIT) is a prototype EUV-wavelength zoneplate microscope that provides high quality aerial image measurements of EUV reticles. To simplify and improve the alignment procedure we have created and tested arrays of aberration-sensitive patterns on EUV reticles and we have compared their images collected with the AIT to the expected shapes obtained by simulating the theoretical wavefront of the system. We obtained a consistent measure of coma and astigmatism in the center of the field of view using two different patterns, revealing a misalignment condition in the optics.

  11. Selecting Sums in Arrays

    DEFF Research Database (Denmark)

    Brodal, Gerth Stølting; Jørgensen, Allan Grønlund

    2008-01-01

    In an array of n numbers each of the \\binomn2+nUnknown control sequence '\\binom' contiguous subarrays define a sum. In this paper we focus on algorithms for selecting and reporting maximal sums from an array of numbers. First, we consider the problem of reporting k subarrays inducing the k largest...... sums among all subarrays of length at least l and at most u. For this problem we design an optimal O(n + k) time algorithm. Secondly, we consider the problem of selecting a subarray storing the k’th largest sum. For this problem we prove a time bound of Θ(n · max {1,log(k/n)}) by describing...... an algorithm with this running time and by proving a matching lower bound. Finally, we combine the ideas and obtain an O(n· max {1,log(k/n)}) time algorithm that selects a subarray storing the k’th largest sum among all subarrays of length at least l and at most u....

  12. Electromagnetically Clean Solar Arrays

    Science.gov (United States)

    Stem, Theodore G.; Kenniston, Anthony E.

    2008-01-01

    The term 'electromagnetically clean solar array' ('EMCSA') refers to a panel that contains a planar array of solar photovoltaic cells and that, in comparison with a functionally equivalent solar-array panel of a type heretofore used on spacecraft, (1) exhibits less electromagnetic interferences to and from other nearby electrical and electronic equipment and (2) can be manufactured at lower cost. The reduction of electromagnetic interferences is effected through a combination of (1) electrically conductive, electrically grounded shielding and (2) reduction of areas of current loops (in order to reduce magnetic moments). The reduction of cost is effected by designing the array to be fabricated as a more nearly unitary structure, using fewer components and fewer process steps. Although EMCSAs were conceived primarily for use on spacecraft they are also potentially advantageous for terrestrial applications in which there are requirements to limit electromagnetic interference. In a conventional solar panel of the type meant to be supplanted by an EMCSA panel, the wiring is normally located on the back side, separated from the cells, thereby giving rise to current loops having significant areas and, consequently, significant magnetic moments. Current-loop geometries are chosen in an effort to balance opposing magnetic moments to limit far-0field magnetic interactions, but the relatively large distances separating current loops makes full cancellation of magnetic fields problematic. The panel is assembled from bare photovoltaic cells by means of multiple sensitive process steps that contribute significantly to cost, especially if electomagnetic cleanliness is desired. The steps include applying a cover glass and electrical-interconnect-cell (CIC) sub-assemble, connecting the CIC subassemblies into strings of series-connected cells, laying down and adhesively bonding the strings onto a panel structure that has been made in a separate multi-step process, and mounting the

  13. Virtual reality microscope versus conventional microscope regarding time to diagnosis: an experimental study.

    Science.gov (United States)

    Randell, Rebecca; Ruddle, Roy A; Mello-Thoms, Claudia; Thomas, Rhys G; Quirke, Phil; Treanor, Darren

    2013-01-01

      To create and evaluate a virtual reality (VR) microscope that is as efficient as the conventional microscope, seeking to support the introduction of digital slides into routine practice.   A VR microscope was designed and implemented by combining ultra-high-resolution displays with VR technology, techniques for fast interaction, and high usability. It was evaluated using a mixed factorial experimental design with technology and task as within-participant variables and grade of histopathologist as a between-participant variable. Time to diagnosis was similar for the conventional and VR microscopes. However, there was a significant difference in the mean magnification used between the two technologies, with participants working at a higher level of magnification on the VR microscope.   The results suggest that, with the right technology, efficient use of digital pathology for routine practice is a realistic possibility. Further work is required to explore what magnification is required on the VR microscope for histopathologists to identify diagnostic features, and the effect on this of the digital slide production process. © 2012 Blackwell Publishing Limited.

  14. Dependable Design Flow for Protection Systems using Programmable Logic Devices

    CERN Document Server

    Kwiatkowski, M

    2011-01-01

    Programmable Logic Devices (PLD) such as Field Programmable Gate Arrays (FPGA) are becoming more prevalent in protection and safety-related electronic systems. When employing such programmable logic devices, extra care and attention needs to be taken. The final synthesis result, used to generate the bit-stream to program the device, must be shown to meet the design’s requirements. This paper describes how to maximize confidence using techniques such as Formal Methods, exhaustive Hardware Description Language (HDL) code simulation and hardware testing. An example is given for one of the critical functions of the Safe Machine Parameters (SMP) system, used in the protection of the Large Hadron Collider (LHC) at CERN. CERN is also working towards an adaptation of the IEC- 61508 lifecycle designed for Machine Protection Systems (MPS), and the High Energy Physics environment, implementation of a protection function in FPGA code is only one small step of this lifecycle. The ultimate aim of this project is to cre...

  15. DMD-based programmable wide field spectrograph for Earth observation

    Science.gov (United States)

    Zamkotsian, Frédéric; Lanzoni, Patrick; Liotard, Arnaud; Viard, Thierry; Costes, Vincent; Hébert, Philippe-Jean

    2015-03-01

    In Earth Observation, Universe Observation and Planet Exploration, scientific return could be optimized in future missions using MOEMS devices. In Earth Observation, we propose an innovative reconfigurable instrument, a programmable wide-field spectrograph where both the FOV and the spectrum could be tailored thanks to a 2D micromirror array (MMA). For a linear 1D field of view (FOV), the principle is to use a MMA to select the wavelengths by acting on intensity. This component is placed in the focal plane of a first grating. On the MMA surface, the spatial dimension is along one side of the device and for each spatial point, its spectrum is displayed along the perpendicular direction: each spatial and spectral feature of the 1D FOV is then fully adjustable dynamically and/or programmable. A second stage with an identical grating recomposes the beam after wavelengths selection, leading to an output tailored 1D image. A mock-up has been designed, fabricated and tested. The micromirror array is the largest DMD in 2048 x 1080 mirrors format, with a pitch of 13.68μm. A synthetic linear FOV is generated and typical images have been recorded o at the output focal plane of the instrument. By tailoring the DMD, we could modify successfully each pixel of the input image: for example, it is possible to remove bright objects or, for each spatial pixel, modify the spectral signature. The very promising results obtained on the mock-up of the programmable wide-field spectrograph reveal the efficiency of this new instrument concept for Earth Observation.

  16. Universal programmable quantum circuit schemes to emulate an operator.

    Science.gov (United States)

    Daskin, Anmer; Grama, Ananth; Kollias, Giorgos; Kais, Sabre

    2012-12-21

    Unlike fixed designs, programmable circuit designs support an infinite number of operators. The functionality of a programmable circuit can be altered by simply changing the angle values of the rotation gates in the circuit. Here, we present a new quantum circuit design technique resulting in two general programmable circuit schemes. The circuit schemes can be used to simulate any given operator by setting the angle values in the circuit. This provides a fixed circuit design whose angles are determined from the elements of the given matrix-which can be non-unitary-in an efficient way. We also give both the classical and quantum complexity analysis for these circuits and show that the circuits require a few classical computations. For the electronic structure simulation on a quantum computer, one has to perform the following steps: prepare the initial wave function of the system; present the evolution operator U = e(-iHt) for a given atomic and molecular Hamiltonian H in terms of quantum gates array and apply the phase estimation algorithm to find the energy eigenvalues. Thus, in the circuit model of quantum computing for quantum chemistry, a crucial step is presenting the evolution operator for the atomic and molecular Hamiltonians in terms of quantum gate arrays. Since the presented circuit designs are independent from the matrix decomposition techniques and the global optimization processes used to find quantum circuits for a given operator, high accuracy simulations can be done for the unitary propagators of molecular Hamiltonians on quantum computers. As an example, we show how to build the circuit design for the hydrogen molecule.

  17. Environmental TEM in an Aberration Corrected Microscope

    DEFF Research Database (Denmark)

    Hansen, Thomas Willum; Wagner, Jakob Birkedal

    the microscope column. The effects of gas on the electron wave in the objective lens are not well understood and needs further attention. Imaging samples with a simple geometry, such as gold particles on a flat graphene substrate and analyzing the variations in contrast, provides a means for understanding......The increasing use of environmental transmission electron microscopy (ETEM) in materials science provides exciting new possibilities for investigating chemical reactions and understanding both the interaction of fast electrons with gas molecules and the effect of the presence of gas on high......‐resolution imaging. A gaseous atmosphere in the pole‐piece gap of the objective lens of the microscope alters both the incoming electron wave prior to interaction with the sample and the outgoing wave below the sample. Whereas conventional TEM samples are usually thin (below 10‐20 nm), the gas in the environmental...

  18. Development of Scanning Ultrafast Electron Microscope Capability.

    Energy Technology Data Exchange (ETDEWEB)

    Collins, Kimberlee Chiyoko [Sandia National Lab. (SNL-CA), Livermore, CA (United States); Talin, Albert Alec [Sandia National Lab. (SNL-CA), Livermore, CA (United States); Chandler, David W. [Sandia National Lab. (SNL-CA), Livermore, CA (United States); Michael, Joseph R. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)

    2016-11-01

    Modern semiconductor devices rely on the transport of minority charge carriers. Direct examination of minority carrier lifetimes in real devices with nanometer-scale features requires a measurement method with simultaneously high spatial and temporal resolutions. Achieving nanometer spatial resolutions at sub-nanosecond temporal resolution is possible with pump-probe methods that utilize electrons as probes. Recently, a stroboscopic scanning electron microscope was developed at Caltech, and used to study carrier transport across a Si p-n junction [ 1 , 2 , 3 ] . In this report, we detail our development of a prototype scanning ultrafast electron microscope system at Sandia National Laboratories based on the original Caltech design. This effort represents Sandia's first exploration into ultrafast electron microscopy.

  19. Scanning tunneling microscope assembly, reactor, and system

    Science.gov (United States)

    Tao, Feng; Salmeron, Miquel; Somorjai, Gabor A

    2014-11-18

    An embodiment of a scanning tunneling microscope (STM) reactor includes a pressure vessel, an STM assembly, and three spring coupling objects. The pressure vessel includes a sealable port, an interior, and an exterior. An embodiment of an STM system includes a vacuum chamber, an STM reactor, and three springs. The three springs couple the STM reactor to the vacuum chamber and are operable to suspend the scanning tunneling microscope reactor within the interior of the vacuum chamber during operation of the STM reactor. An embodiment of an STM assembly includes a coarse displacement arrangement, a piezoelectric fine displacement scanning tube coupled to the coarse displacement arrangement, and a receiver. The piezoelectric fine displacement scanning tube is coupled to the coarse displacement arrangement. The receiver is coupled to the piezoelectric scanning tube and is operable to receive a tip holder, and the tip holder is operable to receive a tip.

  20. Biofilm Formation in Microscopic Double Emulsion Droplets

    Science.gov (United States)

    Chang, Connie; Weitz, David

    2012-02-01

    In natural, medical, and industrial settings, there exist surface-associated communities of bacteria known as biofilms. These highly structured films are composed of bacterial cells embedded within self-produced extracellular matrix, usually composed of exopolysaccharides, proteins, and nucleic acids; this matrix serves to protect the bacterial community from antibiotics and environmental stressors. Here, we form biofilms encapsulated within monodisperse, microscopically-sized double emulsion droplets using microfluidics. The bacteria self-organize at the inner liquid-liquid droplet interfaces, multiply, and differentiate into extracellular matrix-producing cells, forming manifold three-dimensional shell-within-a-shell structures of biofilms, templated upon the inner core of spherical liquid droplets. By using microfluidics to encapsulate bacterial cells, we have the ability to view individual cells multiplying in microscopically-sized droplets, which allows for high-throughput analysis in studying the genetic program leading to biofilm development, or cell signaling that induces differentiation.

  1. Microscopic dynamics of glass-forming polymers

    CERN Document Server

    Zorn, R

    2003-01-01

    The microscopic dynamics of glass-forming materials, especially polymers, is a topic of strong current interest and often heated debate. In this review an overview of the most common dynamical phenomena in glass-forming polymers will be presented: alpha relaxation, beta relaxation, 'boson peak', and 'fast process' (beta sub f sub a sub s sub t relaxation). The experimental results presented will be mainly from inelastic and quasielastic neutron scattering. Several mostly unanswered questions arise from the experimental findings, e.g.: Is the alpha relaxation of heterogeneous or homogeneous origin? Is there any relation between the ubiquitous low-temperature vibrational properties of glasses and the alpha relaxation? Different theoretical and model approaches will be mentioned, e.g. mode-coupling theory, the coupling model, the vibration-relaxation model. The limitations of these attempts will be demonstrated leading to the conclusion that currently there is no theory describing the microscopic dynamics of pol...

  2. A Scanning Quantum Cryogenic Atom Microscope

    CERN Document Server

    Yang, Fan; Taylor, Stephen F; Turner, Richard W; Lev, Benjamin L

    2016-01-01

    Microscopic imaging of local magnetic fields provides a window into the organizing principles of complex and technologically relevant condensed matter materials. However, a wide variety of intriguing strongly correlated and topologically nontrivial materials exhibit poorly understood phenomena outside the detection capability of state-of-the-art high-sensitivity, high-resolution scanning probe magnetometers. We introduce a quantum-noise-limited scanning probe magnetometer that can operate from room-to-cryogenic temperatures with unprecedented DC-field sensitivity and micron-scale resolution. The Scanning Quantum Cryogenic Atom Microscope (SQCRAMscope) employs a magnetically levitated atomic Bose-Einstein condensate (BEC), thereby providing immunity to conductive and blackbody radiative heating. The SQCRAMscope has a noise floor of 300 pT and provides a 100x improvement in magnetic flux sensitivity over previous atomic scanning probe magnetometers. These capabilities are carefully benchmarked by imaging magnet...

  3. Fluorescence microscope by using computational ghost imaging

    Directory of Open Access Journals (Sweden)

    Mizutani Yasuhiro

    2015-01-01

    Full Text Available We propose a fluorescence microscope by using the computational Ghost imaging (CGI for observing a living cell for a long duration over an hour. There is a problem for observing a cell about light-induced bleaching fora ling-term observation.Toover come the problem, we focused on an advantageof sensitivityof the CGI as second order colleration for an imaging with weak intensity excitation light. Setting for the CGI, a DMD projector was installed at an eye-piece part of a microscope and fluorescent light was detected using a bucket detectorofa photo-multiplier tube.Asaresults,wehaveshownthe imagingadvantageoftheCGI under weak light intensity, in addition, we have demonstrated to detect fluorescence images of biological samples for one day.

  4. Specular Microscopic Features of Corneal Endothelial Vacuolation

    Directory of Open Access Journals (Sweden)

    Mozhgan Rezaei Kanavi

    2011-01-01

    Full Text Available Purpose: To introduce a specular microscopic reference image for endothelial vacuolation in donated corneas. Methods: Two corneas from a donor with diffuse, round to oval dark areas at the endothelial level on slit lamp biomicroscopy and one normal-appearing donor cornea underwent specular microscopy, histopathologic evaluation and transmission electron microscopy. Results: Specular microscopy of the two corneas with abnormal-looking endothelium revealed large numbers of dark, round to oval structures within the endothelium in favor of endothelial vacuolation. Light microscopy disclosed variable sized cyst-like structures within the cytoplasm. Transmission electron microscopy showed electronlucent and relatively large-sized intracytoplasmic vacuoles. These features were not observed in the endothelium of the normal cornea. Conclusion: The specular microscopic features of endothelial vacuolation in donated corneas were confirmed by light microscopy and transmission electron microscopy, therefore the specular image may be proposed as a reference to eye banks.

  5. Analytical model of the optical vortex microscope.

    Science.gov (United States)

    Płocinniczak, Łukasz; Popiołek-Masajada, Agnieszka; Masajada, Jan; Szatkowski, Mateusz

    2016-04-20

    This paper presents an analytical model of the optical vortex scanning microscope. In this microscope the Gaussian beam with an embedded optical vortex is focused into the sample plane. Additionally, the optical vortex can be moved inside the beam, which allows fine scanning of the sample. We provide an analytical solution of the whole path of the beam in the system (within paraxial approximation)-from the vortex lens to the observation plane situated on the CCD camera. The calculations are performed step by step from one optical element to the next. We show that at each step, the expression for light complex amplitude has the same form with only four coefficients modified. We also derive a simple expression for the vortex trajectory of small vortex displacements.

  6. Isotope analysis in the transmission electron microscope

    Science.gov (United States)

    Susi, Toma; Hofer, Christoph; Argentero, Giacomo; Leuthner, Gregor T.; Pennycook, Timothy J.; Mangler, Clemens; Meyer, Jannik C.; Kotakoski, Jani

    2016-10-01

    The Ångström-sized probe of the scanning transmission electron microscope can visualize and collect spectra from single atoms. This can unambiguously resolve the chemical structure of materials, but not their isotopic composition. Here we differentiate between two isotopes of the same element by quantifying how likely the energetic imaging electrons are to eject atoms. First, we measure the displacement probability in graphene grown from either 12C or 13C and describe the process using a quantum mechanical model of lattice vibrations coupled with density functional theory simulations. We then test our spatial resolution in a mixed sample by ejecting individual atoms from nanoscale areas spanning an interface region that is far from atomically sharp, mapping the isotope concentration with a precision better than 20%. Although we use a scanning instrument, our method may be applicable to any atomic resolution transmission electron microscope and to other low-dimensional materials.

  7. Diagnosis and treatment of microscopic colitis.

    Science.gov (United States)

    Okamoto, Ryuichi; Negi, Mariko; Tomii, Syohei; Eishi, Yoshinobu; Watanabe, Mamoru

    2016-08-01

    Microscopic colitis (MC) designates two types of chronic diarrhea diseases, which are lymphocytic colitis and collagenous colitis. The prevalence of microscopic colitis is increasing in both Western and Eastern countries, possibly due to the high incidence of colonoscopic survey in chronic diarrhea patients. Although the overall prognosis of MC patients is mostly good, it should be noted that appropriate diagnosis and choice of treatment is required to assure a good clinical outcome for MC patients. Also, a certain population of MC patients may take a severe and refractory clinical course, and thus require advanced clinical care using medications supported by less evidence. In this review, we would like to feature the essential points regarding the diagnosis of MC, and also describe the current standard of treatments for MC patients. In addition, we would like to add some findings from the national survey and research carried out in Japan, to compare those data with the western countries.

  8. EXTRACELLULAR CELLULOLYTIC COMPLEXES PRODUCTION BY MICROSCOPIC FUNGI

    Directory of Open Access Journals (Sweden)

    S. O. Syrchin

    2015-10-01

    Full Text Available The aim of this work was to screen and to study the effect of inducers on the synthesis of the cellulolytic enzyme complexes by microscopic fungi. Cellulolytic and xylanolytic activities were determined by reducing sugar with DNS reagent, and β-glucosidase activity by pNPG hydrolysis. The enzyme preparations were obtained by ammonium sulphate precipitation. Among 32 studied strains of microscopic fungi 14 produced cellulo- and xylanolytic enzyme complexes. Fusarium sp. 5 and Fennellia sp. 2806 demonstrated the highest levels of all studied enzyme activities. Enzyme preparations with high endo-, exoglucanase, xylanase and β-glucosidase activities were obtained from these strains. Fusarium sp. 5 and Fennellia sp. 2806 were active producers of cellulase enzyme complexes during growth on natural substrates. It was shown that inductors of cellulolytic enzymes in Fusarium sp. 5 and Fennellia sp. 2806 differed from the ones in Trichoderma reesei.

  9. Luttinger liquids from a microscopic perspective

    DEFF Research Database (Denmark)

    Valiente, Manuel; Phillips, Lawrence G.; Zinner, Nikolaj T.

    2017-01-01

    Luttinger liquid theory is a powerful and widely applicable framework for modelling one-dimensional many-body quantum systems. Within this framework, one supposes that the macroscopic behaviour of such systems is entirely determined by two phenomenological parameters, g(2) and g(4). While...... theory, and for this reason the interpretation remains untested. By applying Luttinger liquid theory in a simple setting, we show that a widely-held and repeatedly-stated belief, namely that the intrabranch terms appearing in Luttinger's model originate from microscopic intrabranch interactions......, is a misconception. We begin with the microscopic model of an interacting one-dimensional, spin-polarized Fermi gas, which we systematically transform into a Luttinger model by introducing an effective interaction, linearizing the dispersion, and renormalizing. By this method, we are able to show that the usual...

  10. Portable smartphone based quantitative phase microscope

    Science.gov (United States)

    Meng, Xin; Tian, Xiaolin; Yu, Wei; Kong, Yan; Jiang, Zhilong; Liu, Fei; Xue, Liang; Liu, Cheng; Wang, Shouyu

    2018-01-01

    To realize portable device with high contrast imaging capability, we designed a quantitative phase microscope using transport of intensity equation method based on a smartphone. The whole system employs an objective and an eyepiece as imaging system and a cost-effective LED as illumination source. A 3-D printed cradle is used to align these components. Images of different focal planes are captured by manual focusing, followed by calculation of sample phase via a self-developed Android application. To validate its accuracy, we first tested the device by measuring a random phase plate with known phases, and then red blood cell smear, Pap smear, broad bean epidermis sections and monocot root were also measured to show its performance. Owing to its advantages as accuracy, high-contrast, cost-effective and portability, the portable smartphone based quantitative phase microscope is a promising tool which can be future adopted in remote healthcare and medical diagnosis.

  11. Adult Learners' Perceptions of An Undergraduate HRD Degree Completion Programme: Reasons for Entering, Attitudes towards Programme and Impact of Programme

    Science.gov (United States)

    Dwyer, Dan; Thompson, Dale Edward; Thompson, Cecelia K.

    2013-01-01

    The purpose of the study was to evaluate an undergraduate distance education (DE) programme based upon adult learners' perceptions. The study investigated the value of the Human Resource Development programme at the University of Arkansas by examining the students' reasons for returning to college, their attitudes towards the programme and the…

  12. A MEANS FOR CALIBRATING A MICROSCOPE, A METHOD OF PREPARING THE MEANS AND A METHOD OF CALIBRATING A MICROSCOPE

    DEFF Research Database (Denmark)

    2005-01-01

    A means or artefact for calibrating the height/depth or Z axis of a microscope, such as a confocal microscope, an interference microscope or a Scanning Electron Microscope. The artefact comprises a number of tapering or pie-shaped, parallel surfaces each extending from a central axis, whereby all...... surfaces and heights are visible independently of the magnification of the microscope. Thus, the full height range may be calibrated and the linearity thereof checked independently of the magnification.......A means or artefact for calibrating the height/depth or Z axis of a microscope, such as a confocal microscope, an interference microscope or a Scanning Electron Microscope. The artefact comprises a number of tapering or pie-shaped, parallel surfaces each extending from a central axis, whereby all...

  13. Isotope analysis in the transmission electron microscope

    OpenAIRE

    Susi, Toma; Hofer, Christoph; Argentero, Giacomo; Leuthner, Gregor T.; Pennycook, Timothy J.; Mangler, Clemens; Meyer, Jannik C.; Kotakoski, Jani

    2016-01-01

    The {\\AA}ngstr\\"om-sized probe of the scanning transmission electron microscope can visualize and collect spectra from single atoms. This can unambiguously resolve the chemical structure of materials, but not their isotopic composition. Here we differentiate between two isotopes of the same element by quantifying how likely the energetic imaging electrons are to eject atoms. First, we measure the displacement probability in graphene grown from either $^{12}$C or $^{13}$C and describe the proc...

  14. Exploring the environmental transmission electron microscope

    OpenAIRE

    Wagner, Jakob B.; Cavalca, Filippo; Damsgaard, Christian D.; Duchstein, Linus D.L.; Hansen, Thomas W.; Renu Sharma, Peter A. Crozier

    2012-01-01

    The increasing interest and development in the field of in situ techniques have now reached a level where the idea of performing measurements under near realistic conditions has become feasible for transmission electron microscopy (TEM) while maintaining high spatial resolution.In this paper, some of the opportunities that the environmental TEM (ETEM) offers when combined with other in situ techniques will be explored, directly in the microscope, by combining electron-based and photon-based t...

  15. [Color television system for the microscope].

    Science.gov (United States)

    Matsko, D E; Gurevich, E Ia; Elinson, M B; Kobidze, B P; Kholomianskiĭ, M G; Mikhal'chenko, A I

    1992-01-01

    The characteristics of colour TV system made on the basis of microscope MBI-15 with the use of imported details are presented. The system can be used for clinico-anatomical conferences, scientific lectures, in teaching, and allows to avoid laborious preparing of colour slides. The design made it possible to keep information (images) in form of figures (for example, by means of a personal computer) and video-cassettes. This may be used in computer morphometry and quantitative analysis in histochemistry.

  16. Scanning electron microscopic observations on bone.

    Science.gov (United States)

    Anderson, C; Danylchuk, K D

    1977-01-01

    The maceration technique employed in the preparation of specimens of bone for museum purposes has also been found to be of use in the preparation of fresh specimens for study with the scanning electron microscope. The technique requires less technical supervision, permits a greater underprocessing to overprocessing margin, and allows comparability of recent biopsy material with previously macerated bone specimens with no less detail than that found by other authors using other techniques on biopsy material.

  17. Microscopic Colitis: An Approach to Treatment

    Directory of Open Access Journals (Sweden)

    Nilesh Chande

    2008-01-01

    Full Text Available Microscopic colitis – including collagenous colitis and lymphocytic colitis – causes chronic watery diarrhea, usually in middle-aged or elderly patients. There is an association with celiac disease and certain medications. Medical treatment includes various antidiarrheal agents, mesalamine, corticosteroids and immunosuppressant drugs. Rarely, patients require surgery for refractory disease. An evidence-based and practical approach to treatment should optimize the treatment response while minimizing potential adverse events.

  18. The clinical microscope and direct composite veneer

    DEFF Research Database (Denmark)

    Pascotto, Renata C; Benetti, Ana Raquel

    2010-01-01

    This paper presents the advantages and limitations related to the use of a clinical microscope in restorative dentistry, and it demonstrates the aid of magnification during preparation and restoration of a direct composite veneer. Good illumination and visibility is important to adequately viewing...... the adjacent dental tissues so that the resin composite buildup can mimic natural teeth. The reproduction of details results in a naturally esthetic direct veneer....

  19. Individual Microscopic Results Of Bottleneck Experiments

    CERN Document Server

    Bukáček, Marek; Krbálek, Milan

    2016-01-01

    This contribution provides microscopic experimental study of pedestrian motion in front of the bottleneck, explains the high variance of individual travel time by the statistical analysis of trajectories. The analysis shows that this heterogeneity increases with increasing occupancy. Some participants were able to reach lower travel time due more efficient path selection and more aggressive behavior within the crowd. Based on this observations, linear model predicting travel time with respect to the aggressiveness of pedestrian is proposed.

  20. Quantum Protectorate and Microscopic Models of Magnetism

    OpenAIRE

    Kuzemsky, A. L.

    2002-01-01

    Some physical implications involved in a new concept, termed the "quantum protectorate" (QP), are developed and discussed. This is done by considering the idea of quantum protectorate in the context of quantum theory of magnetism. It is suggested that the difficulties in the formulation of quantum theory of magnetism at the microscopic level, that are related to the choice of relevant models, can be understood better in the light of the QP concept . We argue that the difficulties in the formu...

  1. Electrodynamic Arrays Having Nanomaterial Electrodes

    Science.gov (United States)

    Trigwell, Steven (Inventor); Biris, Alexandru S. (Inventor); Calle, Carlos I. (Inventor)

    2013-01-01

    An electrodynamic array of conductive nanomaterial electrodes and a method of making such an electrodynamic array. In one embodiment, a liquid solution containing nanomaterials is deposited as an array of conductive electrodes on a substrate, including rigid or flexible substrates such as fabrics, and opaque or transparent substrates. The nanomaterial electrodes may also be grown in situ. The nanomaterials may include carbon nanomaterials, other organic or inorganic nanomaterials or mixtures.

  2. Combinatorial aspects of covering arrays

    Directory of Open Access Journals (Sweden)

    Charles J. Colbourn

    2004-11-01

    Full Text Available Covering arrays generalize orthogonal arrays by requiring that t -tuples be covered, but not requiring that the appearance of t -tuples be balanced.Their uses in screening experiments has found application in software testing, hardware testing, and a variety of fields in which interactions among factors are to be identified. Here a combinatorial view of covering arrays is adopted, encompassing basic bounds, direct constructions, recursive constructions, algorithmic methods, and applications.

  3. Living matter observations with a novel hyperspectral supercontinuum confocal microscope for VIS to near-IR reflectance spectroscopy.

    Science.gov (United States)

    Bertani, Francesca R; Ferrari, Luisa; Mussi, Valentina; Botti, Elisabetta; Costanzo, Antonio; Selci, Stefano

    2013-10-25

    A broad range hyper-spectroscopic microscope fed by a supercontinuum laser source and equipped with an almost achromatic optical layout is illustrated with detailed explanations of the design, implementation and data. The real novelty of this instrument, a confocal spectroscopic microscope capable of recording high resolution reflectance data in the VIS-IR spectral range from about 500 nm to 2.5 μm wavelengths, is the possibility of acquiring spectral data at every physical point as defined by lateral coordinates, X and Y, as well as at a depth coordinate, Z, as obtained by the confocal optical sectioning advantage. With this apparatus we collect each single scanning point as a whole spectrum by combining two linear spectral detector arrays, one CCD for the visible range, and one InGaAs infrared array, simultaneously available at the sensor output channel of the home made instrument. This microscope has been developed for biomedical analysis of human skin and other similar applications. Results are shown illustrating the technical performances of the instrument and the capability in extracting information about the composition and the structure of different parts or compartments in biological samples as well as in solid statematter. A complete spectroscopic fingerprinting of samples at microscopic level is shown possible by using statistical analysis on raw data or analytical reflectance models based on Abelés matrix transfer methods.

  4. Living Matter Observations with a Novel Hyperspectral Supercontinuum Confocal Microscope for VIS to Near-IR Reflectance Spectroscopy

    Directory of Open Access Journals (Sweden)

    Francesca R. Bertani

    2013-10-01

    Full Text Available A broad range hyper-spectroscopic microscope fed by a supercontinuum laser source and equipped with an almost achromatic optical layout is illustrated with detailed explanations of the design, implementation and data. The real novelty of this instrument, a confocal spectroscopic microscope capable of recording high resolution reflectance data in the VIS-IR spectral range from about 500 nm to 2.5 μm wavelengths, is the possibility of acquiring spectral data at every physical point as defined by lateral coordinates, X and Y, as well as at a depth coordinate, Z, as obtained by the confocal optical sectioning advantage. With this apparatus we collect each single scanning point as a whole spectrum by combining two linear spectral detector arrays, one CCD for the visible range, and one InGaAs infrared array, simultaneously available at the sensor output channel of the home made instrument. This microscope has been developed for biomedical analysis of human skin and other similar applications. Results are shown illustrating the technical performances of the instrument and the capability in extracting information about the composition and the structure of different parts or compartments in biological samples as well as in solid statematter. A complete spectroscopic fingerprinting of samples at microscopic level is shown possible by using statistical analysis on raw data or analytical reflectance models based on Abelés matrix transfer methods.

  5. Programme Implementers' Experiences of Evaluation Use in ...

    African Journals Online (AJOL)

    Some of these uses included increased collaboration among different organisations and staff at different levels, inculcating evaluative thinking among programme staff, increased ... Key Words: Evaluation, Evaluation Theory, Programme Evaluation, Evaluation Use, Factors Affecting Evaluation Use, Northern Ghana ...

  6. Impact evaluation of child nutrition programmes

    NARCIS (Netherlands)

    Hoorweg, J.C.

    1988-01-01

    Review of current practices and recent developments in impact evaluation of nutrition programmes for preschool children in developing countries. A survey of the major types of nutrition programmes for young children - nutrition education, food supplementation, and nutrition rehabilitation - is

  7. Sustainable Industrial Development Programmes of International ...

    African Journals Online (AJOL)

    However, more insightful corporate entrepreneurship programmes with improved infrastructural and electric power facilities should be encouraged. Increasing support to firms through diverse channels would boost rapid economic development of the sub region. Key words: Sustainable programmes, economic development, ...

  8. South African Antarctic earth science research programme

    CSIR Research Space (South Africa)

    SASCAR

    1984-02-01

    Full Text Available This document describes the past, current and planned future South African earth science research programme in the Antarctic, Southern Ocean and subantarctic regions. The scientific programme comprises five components into which present and future...

  9. Zoom microscope objective using electrowetting lenses.

    Science.gov (United States)

    Li, Lei; Wang, Di; Liu, Chao; Wang, Qiong-Hua

    2016-02-08

    We report a zoom microscope objective which can achieve continuous zoom change and correct the aberrations dynamically. The objective consists of three electrowetting liquid lenses and two glass lenses. The magnification is changed by applying voltages on the three electrowetting lenses. Besides, the three electrowetting liquid lenses can play a role to correct the aberrations. A digital microscope based on the proposed objective is demonstrated. We analyzed the properties of the proposed objective. In contrast to the conventional objectives, the proposed objective can be tuned from ~7.8 × to ~13.2 × continuously. For our objective, the working distance is fixed, which means no movement parts are needed to refocus or change its magnification. Moreover, the zoom objective can be dynamically optimized for a wide range of wavelength. Using such an objective, the fabrication tolerance of the optical system is larger than that of a conventional system, which can decrease the fabrication cost. The proposed zoom microscope objective cannot only take place of the conventional objective, but also has potential application in the 3D microscopy.

  10. Adaption of HPS to the MICROSCOPE Mission

    Science.gov (United States)

    List, Meike; Bremer, Stefanie; Laemmerzahl, Claus

    The French space mission MICROSCOPE aims at testing the Equivalence Principle (EP) up to an accuracy of 10-15 . The experiment will be carried out on a satellite which is developed and produced within the CNES Myriade series. The measuring accuracy will be achieved by means of two high-precision capacitive differential accelerometers, that are built by the French institute ONERA. Currently, the HPS (High Performance satellite dynamics Simulator), a tool to support mission modeling, is adapted to the MICROSCOPE mission for the simulation of test mass and satellite dynamics. This tool is developed in cooperation with the DLR Institute of Space Systems. It includes possibilities for modeling environmental disturbances like solar radiation pressure as well as mission specific design aspects (e.g. geometry, number of accelerometers). At ZARM, which is member of the MICROSCOPE performance team, the upcoming data evaluation process is prepared using the HPS. Therefore a comprehensive simulation of the real system including the science signal and all error sources is built. The talk will contain a description of the HPS structure as well as of the implementation of environment models. Secondly, the actual status of the mission modeling will be presented.

  11. Image inpainting for the differential confocal microscope

    Science.gov (United States)

    Qiu, Lirong; Wang, Lei; Liu, Dali; Hou, Maosheng; Zhao, Weiqian

    2015-02-01

    In the process of zero-crossing trigger measurement of differential confocal microscope, the sample surface features or tilt will cause the edges can't be triggered. Meanwhile, environment vibration can also cause false triggering. In order to restore the invalid information of sample, and realize high-precision surface topography measurement, Total Variation (TV) inpainting model is applied to restore the scanning images. Emulation analysis and experimental verification of this method are investigated. The image inpainting algorithm based on TV model solves the minimization of the energy equation by calculus of variations, and it can effectively restore the non-textured image with noises. Using this algorithm, the simulation confocal laser intensity curve and height curve of standard step sample are restored. After inpainting the intensity curve below the threshold is repaired, the maximum deviation from ideal situation is 0.0042, the corresponding edge contour of height curve is restored, the maximum deviation is 0.1920, which proves the algorithm is effective. Experiment of grating inpainting indicates that the TV algorithm can restore the lost information caused by failed triggering and eliminate the noise caused by false triggering in zero-crossing trigger measurement of differential confocal microscope. The restored image is consistent with the scanning result of OLYMPUS confocal microscope, which can satisfy the request of follow-up measurement analysis.

  12. The JOSHUA (J80) system programmer`s manual

    Energy Technology Data Exchange (ETDEWEB)

    Smetana, A.O.; McCort, J.T.; Westmoreland, B.W.

    1993-08-01

    The JOSHUA system routines (JS routines) can be used to manage a JOSHUA data base and execute JOSHUA modules on VAX/VMS and IBM/MVS computer systems. This manual provides instructions for using the JS routines and information about the internal data structures and logic used by the routines. It is intended for use primarily by JOSHUA systems programmers, however, advanced applications programmers may also find it useful. The JS routines are, as far as possible, written in ANSI FORTRAN 77 so that they are easily maintainable and easily portable to different computer systems. Nevertheless, the JOSHUA system provides features that are not available in ANSI FORTRAN 77, notably dynamic module execution and a data base of named, variable length, unformatted records, so some parts of the routines are coded in nonstandard FORTRAN or assembler (as a last resort). In most cases, the nonstandard sections of code are different for each computer system. To make it easy for programmers using the JS routines to avoid naming conflicts, the JS routines and common block all have six character names that begin with the characters {open_quotes}JS.{close_quotes} Before using this manual, one should be familiar with the JOSHUA system as described in {open_quotes}The JOSHUA Users` Manual,{close_quotes} ANSI FORTRAN 77, and at least one of the computer systems for which the JS routines have been implemented.

  13. Compact dynamic microfluidic iris array

    Science.gov (United States)

    Kimmle, Christina; Doering, Christoph; Steuer, Anna; Fouckhardt, Henning

    2011-09-01

    A dynamic microfluidic iris is realized. Light attenuation is achieved by absorption of an opaque liquid (e.g. black ink). The adjustment of the iris diameter is achieved by fluid displacement via a transparent elastomer (silicone) half-sphere. This silicone calotte is hydraulically pressed against a polymethylmethacrylate (PMMA) substrate as the bottom window, such that the opaque liquid is squeezed away, this way opening the iris. With this approach a dynamic range of more than 60 dB can be achieved with response times in the ms to s regime. The design allows the realization of a single iris as well as an iris array. So far the master for the molded silicone structure was fabricated by precision mechanics. The aperture diameter was changed continuously from 0 to 8 mm for a single iris and 0 to 4 mm in case of a 3 x 3 iris array. Moreover, an iris array was combined with a PMMA lens array into a compact module, the distance of both arrays equaling the focal length of the lenses. This way e.g. spatial frequency filter arrays can be realized. The possibility to extend the iris array concept to an array with many elements is demonstrated. Such arrays could be applied e.g. in light-field cameras.

  14. A theory evaluation of an induction programme

    Directory of Open Access Journals (Sweden)

    Kenrick Hendricks

    2012-07-01

    Full Text Available Orientation: An induction programme is commonly used to help new employees understand their job within the organisation. Research purpose: The main aim of this study was to examine whether or not the programme theory of an induction programme was plausible and would lead to the intended outcomes as described by the programme manager.Motivation for the study: Induction training is one of the most common training programmes in an organisation. However, there is little research to evaluate whether or not the activities of an induction programme will lead to the intended outcomes of such a programme.Research design, approach and method: This theory evaluation used a descriptive design. One hundred and thirteen employees of a media company completed a ten-item, five-point Likert scale which measured their perceptions of the programme’s outcome, identification with the organisation and intentions to stay with the organisation.Main findings: From this theory evaluation it was apparent that an induction programme based on an implausible programme theory could be problematic. An implausible programme theory affects the design of the programme activities and unsuitable activities may not deliver the desired outcomes.Practical/managerial implications: The intention of the evaluation is to guide human resource managers through a process of replacing an implausible programme theory with one that is plausible, and which ensures better alignment of programme activities and outcomes.Contribution/value-add: The evaluators showed how a plausible programme theory could improve programme design. This redesigned induction programme may lead to benefits, such as staff retention and company identification, rather than the vague assumption that it has been conforming to a legal obligation.

  15. Agri-Environment Programme for Croatia

    OpenAIRE

    Znaor, Darko; Karoglan Todorović, Sonja

    2004-01-01

    In the period 2002-2004, the Netherlands Government's Pin-Matra programme funded an international project aiming to support the introduction of an agri-environment programme (AE) in Croatia. The project resulted in proposals for national and pilot agri-environment programmes. The project addressed key actors working on agri-environmental issues in Croatia, such as government representatives, scientists, farmers, environmental and nature conservation NGOs. An AE Programme has been operatin...

  16. Practical assessment of the SWMM programme

    Science.gov (United States)

    Hlustik, P.

    2017-10-01

    The article describes the advantages and disadvantages of the SWMM programme user environment when working with it. The Storm Water Management Model (SWMM) is a programme developed by the U.S. EPA (United States Environmental Protection Agency). The SWMM programme is used worldwide to plan, analyse and design rainfall-runoff, combined and separate sanitary sewage systems and other drainage systems in urban areas [1]. The programme is freely available to download from the U.S. EPA website [2].

  17. Composite thermal micro-actuator array for tactile displays

    Science.gov (United States)

    Enikov, Eniko T.; Lazarov, Kalin V.

    2003-07-01

    Tactile perception of complex symbols through tactile stimulation is an exciting application of a phenomenon known as tactile illusion (TI). Sensation of motion on the skin can be produced by a limited number of discrete mechanical actuators applying light pressure over the skin. This phenomenon can thus be used as a neurophysiological testing tool to determine central and peripheral nervous system injury as well as providing an additional human-machine communication channel. This paper describes the development of a 4 x 5 actuator array of individual vibrating pixels for fingertip tactile communication. The array is approximately one square centimeter and utilizes novel micro-clutch MEMS technology. The individual pixels are turned ON and OFF by pairs of microscopic composite thermal actuators, while the main vibration is generated by a vibrating piezo-electric plate. The physiological parameters required for inducing tactile illusion are described. The fabrication sequence for the thermal micro-actuators along with actuation results are also presented.

  18. Microfabricated Fountain Pens for High-Density DNA Arrays

    Science.gov (United States)

    Reese, Matthew O.; van Dam, R. Michae; Scherer, Axel; Quake, Stephen R.

    2003-01-01

    We used photolithographic microfabrication techniques to create very small stainless steel fountain pens that were installed in place of conventional pens on a microarray spotter. Because of the small feature size produced by the microfabricated pens, we were able to print arrays with up to 25,000 spots/cm2, significantly higher than can be achieved by other deposition methods. This feature density is sufficiently large that a standard microscope slide can contain multiple replicates of every gene in a complex organism such as a mouse or human. We tested carryover during array printing with dye solution, labeled DNA, and hybridized DNA, and we found it to be indistinguishable from background. Hybridization also showed good sequence specificity to printed oligonucleotides. In addition to improved slide capacity, the microfabrication process offers the possibility of low-cost mass-produced pens and the flexibility to include novel pen features that cannot be machined with conventional techniques. PMID:12975313

  19. A kind of synthetic nanopillar arrays for studying single biomolecule.

    Science.gov (United States)

    Li, Qiang; Wang, Kaige; Xi, Dan; Dang, Weijun; Ren, Zhaoyu; He, Qinli; Bai, Jintao; Gu, Changzhi

    2010-11-01

    The anodic aluminum oxide (AAO) template with ordered pores was firstly fabricated in oxalic acid solutions using two-step anodization method. Then, a layer of polymethylmethacrylate (PMMA) was uniformly laid on one surface of the AAO template by a Spin-Coater, then baked and cooled them, after that, the H3PO4 solution was utilized to dissolve the residual aluminum and barrier layer, as the result, the functional nanopillar arrays were achieved. Finally, the morphology of the functional PMMA nanopillars was examined with the Scanning Electron Microscope (SEM) and the properties were discussed. The functional nanopillar arrays could be applied to the micro and nano-scale devices as the sensors for the biological, chemical and single molecular detection.

  20. Cascading Constrained 2-D Arrays using Periodic Merging Arrays

    DEFF Research Database (Denmark)

    Forchhammer, Søren; Laursen, Torben Vaarby

    2003-01-01

    We consider a method for designing 2-D constrained codes by cascading finite width arrays using predefined finite width periodic merging arrays. This provides a constructive lower bound on the capacity of the 2-D constrained code. Examples include symmetric RLL and density constrained codes...